Pasco Specialty And Mfg Motion Sensor Ps 2103A Users Manual 012 09625B INST SHT
2015-02-06
: Pasco-Specialty-And-Mfg Pasco-Specialty-And-Mfg-Motion-Sensor-Ps-2103A-Users-Manual-516832 pasco-specialty-and-mfg-motion-sensor-ps-2103a-users-manual-516832 pasco-specialty-and-mfg pdf
Open the PDF directly: View PDF
.
Page Count: 5
| Download | |
| Open PDF In Browser | View PDF |
Instruction Sheet 012- 09625B Motion Sensor PS-2103A PASPORT Plug Included Equipment Part Number Motion Sensor PS-2103A Target Indicator Additional Equipment Required PASPORT-compatible Interface See PASCO catalog or www.pasco.com Range Switch Rotating Head Quick Start 1. Connect the Motion Sensor to your PASPORT-compatible interface (such as the 850 Universal Interface or the SPARK Science Learning System). 2. If you are using a computer, connect the PASCO interface to it and start the data acquisition software (such as PASCO Capstone or SPARKvue). 3. Place an object in front of the sensor at least 15 cm away. 4. Click “Record” or press “Start to begin recording data. 5. Move the object in a straight line directly away from or toward the sensor. Introduction The PS-2103A Motion Sensor works with your PASCO interface to measure and record position, velocity, and acceleration. It produces a series of ultrasonic pulses and detects the sound reflecting back from an object in front of it. The interface measures the times between outgoing pulses and returning echoes. From these measurements, it determines the position, velocity, and acceleration of the object. This instruction sheet includes procedures for setting up the hardware and software collecting data, changing the sample rate, calibrating the sensor, mounting the sensor on equipment, and troubleshooting. ® Clips for mounting on track Hole for mounting on rod Ultrasonic Transducer Theory of operation is described and specifications are listed at the end of these instructions. Note: Essential PASCO Capstone, SPARK SLS, and GLX tasks are described briefly in this instruction sheet. For more information, refer to the User’s Guide or the on-line help for the interface and/or the data acquisition software. +1 916-786-3800 support@pasco.com Motion Sensor PS- 2103A Set-up SPARK Science Learning System (SLS) • When the sensor is connected to a SPARK SLS, the screen shows a list of the sensor’s parameters (such as position, velocity, and acceleration). • Press a measurements and then press the “Show” icon to create a graph display. To Connect to a PASPORT-compatible Interface 1. Connect the Motion Sensor's plug to a PASPORT input port of your PASCO interface. PASPORT Input Port Sensor Plug (1) Press a measurement Alignment Tab 2. Turn on the interface. If you are using a computer, connect the interface to it and start the data acquisition software. SPARKvue Motion Sensor Screen (2) Press “Show” PASCO Capstone • PASCO Capstone will automatically prepare itself for data collection. In the software, click the “Hardware Setup” icon in the Tools palette to open the Hardware Setup panel. 850 Universal Interface icon SPARKvue Graph Display Motion Sensor icon PASCO Capstone Hardware Setup Panel Xplorer GLX • Confirm that the panel shows the icon of the Motion Sensor connected to the icon of the interface. • To create a graph display, double click a choice in the workbook page, or drag the Graph icon from the Displays palette to the workbook page. • The Xplorer GLX automatically detects the Motion Sensor and opens a graph display of position on the vertical axis and time on the horizontal axis. Graph icon Create a Graph Display 2 ® M o t io n S e n s o r PS-2103A To Aim the Motion Sensor at an Object 2. Click s to stop data collection. 1. 3. Click s again to start recording data in a new data run. Set the range switch to the short range ( range ( ) setting. ) or long Sensor Configuration 2. • Select for measuring a cart on a track. • Select for measuring most other objects. Arrange the Motion Sensor and object so that the Motion Sensor's transducer faces the object. • The object should be at least 15 cm from the transducer. • If the object will move, it should move directly toward or away from the Motion Sensor. • To View Velocity and Acceleration The Position measurement appears by default. You can also enable Velocity and Acceleration measurements. • In the PASCO Capstone graph, click the label of the vertical axis and select Velocity or Acceleration from the Measurements Menu. • In the SPARKvue graph, press the Graph Tools icon to open the Graph Tools palette. Press the Display Properties icon to open the Line Graph Properties screen. Press Velocity or Acceleration and then press OK. Aim the motion sensor slightly up to avoid detecting the tabletop. Graph Tools icon • Display Properties icon On the GLX while viewing any display screen, press c twice to open a data source menu. Select More to expand the menu. Select Velocity or Acceleration. To Change the Sample Rate 3. Remove objects that may interfere with the measurement. These include objects between the sensor and target object, either directly in front of the sensor or to the sides. • Data Collection PASCO Capstone 1. Click Record. The Motion Sensor starts clicking. If a target is in range, the target indicator flashes with each click. PASCO Capstone starts collecting and displaying data. 2. • Click Stop to stop data collection. SPARK SLS 1. Press Start to begin collecting and recording data. 2. Press Stop to end data collection. • In PASCO Capstone, change the Motion Sensor sampling rate by clicking the up or down arrows in the Sample Rate Control tool. Motion Sensor Sample Rate In SPARKvue, press the Sampling Options icon. Select the Sampling Mode, Sample Rate, and Sample Rate Unit in the Sampling Options screen, and then press OK. Sampling Options icon On the GLX, press h + I to open the Sensors screen. Highlight the Sample Rate setting and press + or -. The normal range of sampling rates is between 1 Hz and 50 Hz. At the default rate, the Motion Sensor can measure distance up to 8 m. The maximum distance decreases with increasing sample rate. At very high sample rates (between 50 Hz and 250 Hz), the maximum distance is less than 2 m. Xplorer GLX (Standalone) 1. Press s. The Motion Sensor starts clicking. If a target is in range, the target indicator flashes with each click. The GLX starts collecting and displaying data. ® 3 Motion Sensor PS- 2103A Equipment Mounting Troubleshooting Mount the Motion Sensor as illustrated on a vertical rod (a) or a horizontal rod (b). If the Motion Sensor fails to perform satisfactorily, try these steps: Integrated clips allow it to be attached to the end of a dynamics track (c). • Ensure that the target object is no closer than 15 cm. • Switch the range switch to the other setting. • Adjust the aim left, right, up, or down. In some cases the Motion Sensor works best when it is aimed slightly to the side or above the target in order to exclude interfering objects. • Improve the target by adding a larger or harder surface to reflect ultrasound. A small object can be a better reflector than large object if it has a harder surface. • Remove interfering objects near the target object or sensor. • Increase or decrease the sample rate. A threaded hole in the bottom of the unit (d) is provided for attachment to the PS-2546 Magnetic Bracket (e), the ME-6743 Cart Adapter (f), and other 1/4-20 threaded mounting devices such as a camera tripod. To protect the Motion Sensor from being hit by an object, use a device such as the SE-7256 Motion Sensor Guard (g) or ME-9806 bracket with a rubber band (h). The Motion Sensor can “see through” a wire screen or rubber band placed close to the transducer. (b) Theory of Operation The Motion Sensor uses an electrostatic transducer as both a speaker and a microphone. For each sample, the transducer transmits a burst of 16 ultrasonic pluses with a frequency of about 49 kHz. This burst of pulses can be heard as a single click. The ultrasonic pulses reflect off an object and return to the sensor. The target indicator on the sensor flashes when the transducer detects an echo. (a) (c) Sound intensity decreases with distance; to compensate, the sensor increases the gain of the receiver amplifier as it waits for the echo. The increased gain allows the sensor to detect an object up to 8 m away. The lower gain at the beginning of the cycle reduces the circuit's sensitivity to echoes from false targets. The sensor measures the time between the trigger rising edge and the echo rising edge. It uses this time and the speed of sound to calculate the distance to the object. To determine velocity, it uses consecutive position measurements to calculate the rate of change of position. Similarly, it determines acceleration using consecutive velocity measurements. (e) (f) (d) (g) 4 (h) ® M o t io n S e n s o r PS-2103A Specifications Minimum Range 15 cm Maximum Range 8m Transducer Rotation 360° Range Settings Short Range: for distance measurement up to 2 m with improved rejection of false target signals and air-track noise Long Range: for distance measurement up to 8 m Mounting Options • On rod up to 12.7 mm diameter • Directly to PASCO dynamics tracks • On table top The European Union WEEE (Waste Electronic and Electrical Equipment) symbol (to the right) and on the product or its packaging indicates that this product must not be disposed of in a standard waste container. Technical Support For assistance with any PASCO product, contact PASCO at: Address: PASCO scientific 10101 Foothills Blvd. Roseville, CA 95747-7100 Phone: +1 916-786-3800 (worldwide) 800-772-8700 (U.S.) Web: www.pasco.com Email: support@pasco.com Limited Warranty For a description of the product warranty, see the PASCO catalog. Copyright The PASCO scientific 012-09625B Motion Sensor Instruction Sheet is copyrighted with all rights reserved. Permission is granted to non-profit educational institutions for reproduction of any part of this manual, providing the reproductions are used only in their laboratories and classrooms, and are not sold for profit. Reproduction under any other circumstances, without the written consent of PASCO scientific, is prohibited. Trademarks PASCO, PASCO scientific, PASPORT, SPARK Science Learning System, SPARKvue, and Xplorer GLX are trademarks or registered trademarks of PASCO scientific, in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of, their respective owners. For more information visit www.pasco.com/legal. Product End of Life Disposal Instructions: This electronic product is subject to disposal and recycling regulations that vary by country and region. It is your responsibility to recycle your electronic equipment per your local environmental laws and regulations to ensure that it will be recycled in a manner that protects human health and the environment. To find out where you can drop off your waste equipment for recycling, please contact your local waste recycle/disposal service, or the place where you purchased the product. ® 5
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : griffith Create Date : 2005:03:03 13:59:16Z Modify Date : 2012:07:26 09:34:49Z XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : Acrobat Distiller 9.5.1 (Windows) Creator Tool : FrameMaker 7.2 Format : application/pdf Title : 012-09625B PS-2103A INST SHT.fm Creator : griffith Document ID : uuid:5df4b8a1-e034-4ae3-843f-2f956f4f931b Instance ID : uuid:237a4632-e85b-495b-8009-fdde942d5f6b Page Mode : UseNone Page Count : 5EXIF Metadata provided by EXIF.tools