Paxton Access 360864 125 kHz Proximity Reader User Manual

Paxton Access Ltd 125 kHz Proximity Reader INSTRUCTION PROXIMITY architectural reader

a href="https://usermanual.wiki/Paxton-Access" itemprop="url"> Paxton Access >

User manual

Ins-30040-US   PROXIMITY architectural reader06/07/2007Technical SupportTechnical help is available:      Monday - Friday from 5am - 5pm PST / 8am - 8pm EST   Other documentation on all Paxton products can be found on our web site - http://www.paxton-access.com/1 800 672 PAXT support@paxton-access.co.ukFittingMount the reader back box ush into the wall.  Care must be taken when doing this, as there is no further adjustment possible within the box.  Screws and plugs are provided for tting the unit to the wall.Line up the two locating pins on the top of the reader with the top plate inside the back box. Once located, the reader can be clipped into the box at the bottom using the clip feature.Check that the reader is located against the surface of the wall. If there is a gap between the reader and the wall, or if the reader will not successfully clip into the box, remove the reader and adjust the mounting plates inside the back box using a 3mm Allen key.To remove the reader, insert the tool provided into the cut out on the underside of the reader.  Push up the clip and pull the reader from the back box.
RedBrownOrangeGreenYellowBlueMauveBlack/WhiteBrownYellowReader 1OrangeKeypad 1+12v0vN.C.N.O.ComN.C.N.O.ComAlarm Output0vContact0vExit0vTamperPSURxTxRelay 1Relay 2ExitContactTamperPSUOK5v12vRedBrownOrangeGreenYellowBlueMauveBlack/WhiteBrownYellowOrangeReader 2Keypad 2PowerRelay 1Relay 2InputsNetworkCAT5 cable codingWhite/GreenGreenWhite/OrangeOrange1234Screen or spare coresfrom network cableSerial number 241821Test ID: 012345678901z-144032 4 8 9 8 0 0 0 0 04RedBrownOrangeGreenYellowBlueMauveExitContactBlackCard reader or keypad 12v 0vN.C.N.O.ComBellPowerDoor relayAlarmwitch2SControlunitInputsWhite Labelled control units only provide 5v at the Red terminal.  The red power wire for the reader should be connected directly to the 12v PCB supply terminal - as per diagram.Cable extensionsRed 12v dcBrownOrangeGreenYellowBlueMauveBlack/WhiteBrownYellowReader 1OrangeKeypad 1+12v0vN.C.N.O.ComN.C.N.O.ComAlarm Output0vContact0vExit0vTamperPSURxTxRelay 1Relay 2ExitContactTamperPSUOK5v12vRedBrownOrangeGreenYellowBlueMauveBlack/WhiteBrownYellowOrangeReader 2Keypad 2PowerRelay 1Relay 2InputsNetworkCAT5 cable codingWhite/GreenGreenWhite/OrangeOrange1234Screen or spare coresfrom network cableCAUTION: for 12v d.c. readers only. Forcorrect connection of old 5v readers, refer to instructions.Serial number 241821Test ID: 012345678901z-144032 4 8 9 8 0 0 0 0 0 4Red 12VBrownOrangeGreenYellowBlueMauveExitContactBlackCard reader or keypad 12v 0vN.C.N.O.ComBellPowerDoor relayAlarmwitch2SControlunitInputsCAUTION: For 12V d.c. readers only. For correct connection of old readers, refer to instructions.Readers can be extended using Belden CR9540 10-core overall screened cable. The maximum cable length between reader and control unit is 100 yards.Wiring
Download:
Mirror Download [FCC.gov]
Document ID828814
Application ID1j1TzCJKVLH87IXBRZhfeA==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize101.17kB (1264592 bits)
Date Submitted2007-08-14 00:00:00
Date Available2007-08-14 00:00:00
Creation Date2007-07-06 15:16:41
Producing SoftwareAdobe PDF Library 7.0
Document Lastmod2007-07-11 12:24:01
Document TitleINSTRUCTION - PROXIMITY architectural reader
Document CreatorAdobe InDesign CS2 (4.0.5)
FCC ID Filing: USE360864

Navigation menu