Product Detail Manual

2016-08-16

: Pdf 1000271423-Attachment 1000271423-Attachment B3 unilog

Open the PDF directly: View PDF PDF.
Page Count: 2

Catalog
Number
Notes
Type
Series Housing color Lamp type (2 heads) Options
6 Volts
IND618 18W
IND654 54W
IND6100 100W1
12 Volts
IND1236 36W
IND1254 54W
IND12100 100W2
IND12150 150W2
IND12300 300W2
IND12450 450W2
24 Volts
IND24100 100W2
IND24450 450W1,2
(blank) Gray front
/navy back
W White
6 Volts 24 Volts
PAR36 Composite PAR36 Composite
(blank) 9W/6V krypton (blank) 18W/24V incand.
H1206 12W/6V halogen H2024 20W/24V halogen
H2006 20W/6V halogen PAR36 Sealed-Beam
12 Volts N5024S 50W/24V incand.
PAR36 Composite
(blank) 9W/12V krypton
H1212 12W/12V halogen
H2012 20W/12V halogen
PAR36 Sealed-Beam
H3512S 35W/12V halogen
H5012S 50W/12V halogen
(blank) Damp location 50° F to 104° F (10° C to 40° C).
XTRA Extra package. Features remote test, time delay and damp location 50°F
to 104° F (10° C to 40° C).4
SEL Select package. Features self-diagnostics, time delay, audible failure
indication and damp location 50° F to 104° F (10° C to 40° C).
PREM Premium package. Features high-temperature ni-cad battery (IND618
and IND1236 only) or high-temperature lead calcium battery
(IND12100 only), self-diagnostics, time delay, audible failure indication
and damp location. UL listed for 32° F to 131° F(0° C to 55° C).5, 7
ULT Ultimate package. Features heater, thermostat and battery blanket with
a high temperature ni-cad battery (IND618 and IND1236 only) or high-
temperature lead-calcium battery (IND12100 only), self-diagnostics,
time delay, audible failure indication and damp location. UL listed for
-40° F to 131° F (-40° C to 55o C).5, 7
ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: IND12100 H5012S SEL
NOTES:
1 DL listed for indoor applications.
2 Not suitable for ceiling mount.
3 Required for ceiling mount. Color is not a factor. See spec sheet ELA-IND-PM-CM-RHB-R3.
4 Must order a Remote transmitter (ELA RTT). One per job required. See spec sheet ELA-RTT-BS.
5 Only available on IND618, IND1236 and IND12100.
6 ELA IND PM accessory cannot be used with the IND12100 PREM or IND12100 ULT. Color is not a factor.
See spec sheet ELA-IND-PM-CM-RHB-R3.
7 IND12100 PREM and IND12100 ULT come in a larger housing size.
8 See spec sheet ELA-WG.
9 See spec sheet ELA-IND-PM-CM-RHB-R3.
EMERGENCY IND61224
Industrial Emergency Lighting Unit
IND6/12/24
Lead-Acid (SLA) Battery
FEATURES & SPECIFICATIONS
INTENDED USE — Provides minimum 90 minutes of illumination for rated wattage upon loss of AC power.
Unique design for light and heavy industrial applications, as well as heavy commercial environments.
Superior performance lamp heads are ideal for higher mounting heights.
CONSTRUCTION — Rugged, .140" thick, injection-molded thermoplastic (large back housing is .187"
thick, compression-molded composite). Vertical orientation, designed for pole or column mounting. Also
suitable for wall, I-beam and uni-strut mounting. Easy installation with epoxy-coated, corrosion-resistant,
12-gauge steel mounting bracket shipped standard. US Patent No. 6,135,624 – Mounting Bracket
Utility Patent. Conduit entry points located on top and both sides of unit. Maintenance made easy by
tool-less lamp replacement, hinged front cover, printed circuit board mounting shelf and battery belt. US
Patent No. D419,097 – Design Patent.
OPTICS — Lamps: US Patent No. 6,193,395 – Lamp Head Utility patent. Full range of lamp options available from
9W to 50W in sealed-beam or composite versions of incandescent, krypton or halogen lamps. Composite lamps
feature unique field-adjustable beam spread (by turning lamp bezel). Standard lamp is 9W krypton, for 6V and
12V. Standard lamp is 18W incandescent for 24V.
ELECTRICAL — Dual voltage input capacity 120/277.
Brownout protection is standard feature.
AC/LVD reset prevents battery damage from deep discharge.
Current limiting charger.
Thermal protection prevents overheating and charger failure.
Thermal compensation provides optimum charge voltage relative to ambient temperature.
Battery: Sealed, maintenance-free, lead-acid (SLA) battery with capacity for 90 minutes of emergency
operation.
Low-voltage disconnect prevents excessively deep discharge that can permanently damage battery.
Premium and Ultimate options offer high-temperature batteries (IND618, IND1236 and IND12100 only). UL
listed from 32°F to 131°F (0° C to 55° C) (Premium) or -40°F to 131°F (-40° C to 55° C ) (Ultimate).
Single multi-color LED indicator displays two-state charging, test activation and three-state diagnostic
status. Test switch provides manual activation of 30-second diagnostic testing for on-demand visual
inspection. Diagnostic evaluation of LED light source, AC to DC transfer, charging and battery condition.
Continuously monitors AC functionality. Load-learning capability self-calibrates to DC load at first test,
enabling it to detect a lamp failure on future tests. It may be recalibrated at any time by holding down the test
switch for 15 seconds. Self-diagnostic testing for five minutes every 30 days and 30 minutes every six months.
INSTALLATION — Column and pole mounting standard (12-gauge steel mounting bracket included). Other
mounting options available for ceiling mount or I-Beam mounting (see accessories).
LISTINGS — UL damp location listed standard 500-1040F (100-400C). Meets UL924, NFPA 101 (current Life
Safety Code), NEC and OSHA illumination standards. Meets all applicable FCC requirements.
IND12100
Small Housing
IND12150
Large Housing
WARRANTY — Three-year limited warranty. (Battery is prorated.) Complete warranty terms located at
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Note: Specifications subject to change without notice.
Actual performance may differ as a result of end-user environment and application.
Accessories: Order as separate catalog number
ELA RTT Remote test transmitter4ELA IND CM1 Ceiling mount kit for IND6183
ELA WG2M Wire guard - small (18W-100W)8ELA IND CM2 Ceiling mount kit for IND654/1236/12543
ELA WGLG Wireguard - large (150-450W)8ELA IND CM3 Ceiling mount kit for IND61003
ELA BS Banding Strap4ELA IND R3 Pre-pack to install third head9
ELA IND PM Pendant mount kit for IND618/654/61
00/1236/1254/12100/241006
IND6-12-24-
EMERGENCY One Lithonia Way Conyers, GA 30012 Phone: 800-334-8694 Fax: 770-981-8141 www.lithonia.com ©2004-2016 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/18/16
IND6-12-24 INDURA Industrial Emergency Lighting Units, 6/12/24 Volts
MOUNTING
All dimensions are inches (centimeters).
SPECIFICATIONS
ELECTRICAL: Primary Circuit
Type Volts AC Input
Amps1Watts Output
Volts 1-1/2
hrs. 2 hrs. 3 hrs. 4 hrs.
IND618 120 .163 19.6 618 13.5 9 6
277 .069 19.11
IND654 120 .172 20.64 654 40 27 20
277 .075 20.78
IND6100 120 .171 20.5 6100 75 50 37
277 .064 17.7
IND1236 120 .174 20.9 12 36 27 18 13
277 .078 21.61
IND1254 120 .174 20.88 12 54 40 27 20
277 .078 21.6
IND12100 120 .174 20.88 12 100 75 50 37
277 .074 20.49
IND12150 120 .359 43.08 12 150 112 75 56
277 .168 46.54
IND12300 120 .290 34.8 12 300 225 150 112
277 .130 36.1
IND12450 120 .33 39.96 12 450 337 225 168
277 .15 43.77
IND24100 120 .33 39.6 24 100 75 50 37
277 .15 41.55
IND24450 120 .773 92.76 24 450 337 225 168
277 .327 90.58
High-Temperature Nickel-Cadmium
Voltage Shelf life2Typical life3Maintenance4Optimum Temperature5
6/12/24 3 yrs. 7-9 yrs. none 320-1310F (00-550C)
Lead-Acid (SLA)
Voltage Shelf life2Typical life3Maintenance4Optimum Temperature5
6/12/24 1 yr. 3-5 yrs. none 500-1040F (100-400C)
High-Temperature Lead-Acid (SLA)
Voltage Shelf life2Typical life3Maintenance4Optimum Temperature5
6/12/24 1 yr. 5-7 yrs. none 320-1310F (00-550C)
BATTERY
NOTES:
1 For ULT option, consult factory for input power factor, if required.
2 At 77°F (25°C).
3 Based on normal room temperatures and conditions.
4 All life safety equipment, including emergency lighting for path of egress must be maintained, serviced, and tested
in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the required
maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties.
5 Optimum ambient temperature range where unit will provide rated capacity for 90 minutes. Higher and lower
temperatures affect life and capacity.
FLOOD
MEDIUM
SPOT
12-gauge epoxy-coated steel mounting
bracket included with each unit.
KEY FEATURES
Field-adjusted beam pattern for
composite lamps. Order remote transmitter separately.
ELA RTT
18
(45.7)
16
(40.6) 13-1/4
(33.7)
16
(40.6)
12
(31.0)
8-5/8
(22.0)
9
(22.9)
12-1/2
(31.8)
8-3/8
(21.3) 1
(2.5)
2-1/4
(5.7)
3/8
(10.0)
8
(20.3)
3/4
(1.9)
1/4 (6.0)
2-1/4 (57.0)
2-3/4 (7.0)
PHOTOMETRICS
Shipping weight:
IND618 - 13 lbs. (5.9 kgs ) ND12150 - 45 lbs. ( 20.4 kgs)
IND654 - 18 lbs. (8.2 kgs) IIND12300 - 72 lbs. (32.7 kgs)
IND6100 - 23 lbs. (10.4 kgs) IND12450 - 75 lbs. (30.0 kgs)
IND1236 - 18 lbs. (8.2 kgs) IND24100 - 27 lbs. (12.2 kgs)
IND1254 - 18 lbs. (8.2 kgs) IND24450 - 75 lbs. (30.0 kgs)
IND12100 - 27 lbs. (12.2 kgs)
PERFORMANCE DIAGRAMS
ELA IND K0906
One (1) 9 Watt Krypton In Vertical, Base Up Position
HORIZONTAL
VERTICAL
6
4
2
0
2
4
6
6
4
2
0
2
4
6
10 20 30 40 Ft.
10.5 0.3
10.5 0.3
ELA IND K0912
One (1) 9 Watt Krypton In Vertical, Base Up Position
HORIZONTAL
VERTICAL
6
4
2
0
2
4
6
6
4
2
0
2
4
6
10 20 30 Ft.
10.5 0.3
10.5 0.3
Small Housing (18-54W; 100W Standard, XTRA, and SEL)
Large Housing (100W PREM and ULT; 150-450W)
Mounting bracket
3'
26'
IND K0912
Medium Distribution
*Note: Meets Life Safety Code standard minimum
illuminance of 0.1 FC and average illuminance of 1.0
FC. Assumes space of 200'L x 200'W x 30'H, mounting
height: 12', ceiling height: 30', and reflectances:
10/10/10. Analysis based on independently tested
photometrics.
Center-to-center
spacing* yields 26'.
IND K0906
Medium Distribution
Center-to-center
spacing* yields 25.5'. For additional spacing information,
see the complete list of IND ies files.
25.5'
3'