Metalux
HB
LED
20" X 48"
LED High Bay Efficiency
Luminaire
SPECIFICATION FEATURES
Construction
Full body construction is achieved
with channel and end plates, along
w/stiffening brackets and side
rails to help create a strong, clean
finished frame for this luminaire.
Side rails are standard on all
HBLED products.
Electrical
Long-life LED system coupled with
electrical driver to deliver optimal
performance. LED’s available in
4000k and 5000k with a CRI ≥ 80.
cULus listed. Electronic drivers
are available for 120-277V, 347V
and 480V applications. An optional
0-10V dimming driver is available.
Emergency Battery Pack Option
Optional 120V-277V integral
emergency battery pack is
available in 7-watts or 14-watts
to meet critical life-safety lighting
requirements. The 90-minute
batteries provide constant power
to the LED system, ensuring code-
compliance. A test switch/indicator
button can be tested safely from
the ground using a laser pointer,
while the patented EZ Key prevents
accidental discharge of the battery
during construction. See ordering
information for details.
Finish
White enamel finish preceded
by a multistage cleaning cycle,
iron phosphate coating with
rust inhibitor to protect against
contaminants and oxidation.
Optics
Precision designed optics deliver
even illumination. General and
aisle distribution ensures superior
performance to key areas within an
application.
Shielding
Door frame and lens assembly
is optional for more demanding
environments.
Options
Integral Occupancy Sensor
available and provides from 600
sq. ft. up to 1250 sq. ft. of coverage
in a maximum mounting height of
40’ using interchangeable lens caps
provided. Optional integral sensor
system provides occupancy and
daylight harvesting.
Mounting
The HBLED series is ideally suited
for suspension mounting with
optional wire hook and chain
set, or cable mounting. Single
monopoint mounting is also
available with SPM tong hanger.
Compliance
Luminaires are cULus listed for
damp locations -20°C - 55°C
ambient environments in open
configurations with fixed output
(ED option) drivers and 40°C
with dimming drivers. Refer to
ambient chart for complete list.
RoHS compliant, and LED modules
comply with IESNA LM-79 and
LM-80 standards. DesignLights
Consortium™ Qualified and
classified for DLC Standard (some
models are not DLC qualified),
refer to www.designlights.org for
details.
ADF141931
7-13-2016
The HBLED is an outstanding value for a wide variety of applications
and mounting heights. Precision designed optics, multiple distributions,
lumen outputs and color temperatures make the HBLED ideal for
industrial, commercial, manufacturing, gymnasium and other
applications that utilize traditional HID and linear fluorescent high bays.
The proprietary low-power, low-brightness LED module assembly
offers exceptional optical performance with the enhanced benefits of
LED lighting, including energy savings, extended system life, a reduced
carbon footprint.
DESCRIPTION
ENERGY DATA
Input Watts:
12 (12,000 lumens)=104W
18 (18,000 lumens)=152W
24 (24,000 lumens)=203W
30 (30,000 lumens)=228W
36 (36,000 lumens)=307W
48 (48,000 lumens)=401W
2-3/8"
[63mm]
20-3/16" [512mm]
(NARROW DISTRIBUTION)
Safe and convenient means of
disconnecting power
Catalog # Type
Date
Project
Comments
Prepared by
48-1/2" [1232mm]
20-3/16"
[512mm]
4' HOUSING
DIMENSION TOP VIEW
Specifications and
dimensions subject to
change without notice.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
HBLED-LD4-24-W-
UNV-L850-ED2-U
Dimming Driver
Linear LED 5000K
Spacing criterion:
(II) 1.3 x mounting
height, () 1.31 x
mounting height
Lumens: 24002
Input Watts: 203.0W
Effi cacy: 11 8.2 lm/W
Test Report:
HBLED-LD4-24-W-
UNV-L850-ED2-U.
IES
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Candlepower
Angle Along II 45°Across
8323 8323 8323
8353 8295 8312
8274 8210 8233
8115 8068 8098
7890 7860 7905
7616 7594 7647
7275 7270 7329
6891 6900 6959
6432 6465 6520
5941 5979 6027
5379 5443 5404
4769 4827 4669
4093 4104 3015
3326 3228 1868
2503 1580 1441
1701 1042 998
912 583 241
265 146 155
0 0 0
Coefficients of Utilization
Effective fl oor cavity re ectance 20%
rc 80%70% 50%30% 10%0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
119 119 119 119 116 11 6 116 11 6 111 111 111 106 106 106 102 102 102 10 0
109 105 101 97 107 103 99 95 98 95 92 94 92 90 91 89 87 85
100 92 85 79 97 90 84 78 86 81 77 83 79 75 80 76 73 71
91 81 73 66 88 79 72 66 76 70 64 73 68 63 71 66 62 60
83 71 63 56 81 70 62 56 67 60 55 65 59 54 63 58 53 51
76 64 55 48 74 63 54 48 60 53 47 58 52 47 57 51 46 44
70 57 48 42 69 56 48 42 54 47 41 53 46 41 51 45 41 39
65 52 43 37 64 51 43 37 49 42 37 48 41 36 47 41 36 34
61 47 39 33 59 47 38 33 45 38 33 44 37 32 43 37 32 30
57 43 35 30 55 43 35 29 42 34 29 40 34 29 39 33 29 27
53 40 32 27 52 39 32 27 38 31 27 37 31 26 37 31 26 25
2091
0˚ 10˚3
40˚
50˚
70˚
90˚
4182
6274
20˚
80˚
60˚
8365
Zonal Lumen Summary
Zone Lumens % Fixture
0-30
0-40
0-60
0-90
0-180
6577 27.4
10894 45.4
19698 82.1
24002 10 0.0
24002 10 0.0
Luminance Data
Angle
in Deg
Average
0-Deg
cd/sm
Average
45-Deg
cd/sm
Average
90-Deg
cd/sm
45
55
65
75
85
14061 13902 13912
13914 13733 13150
13171 12311 7019
11003 6317 5902
5094 2342 2315
Modular F-Bay Power Supply Option
1. Modular Power Supply Receptacle supplied
mounted into xture Access Plate
2. Modular Power Cord & Plugs in 120, 277, 347,
& 480V congurations for easy plug & power
into existing supply
Modular Motion Sensor Option
suppliedwith Mounting Box and
Modular Power Supply Receptacle
No internal xture
access required for
installation or
disconnecting power
Code Compliance
•UL/cUL Certied for Make/Break
under load (UL2549)
Meets NEC requirements for
ballast disconnect (NEC 410.73G)
Allows for addition of Occupancy
Sensor without hard connections
•Receptacles complete with
insulating/dust cap
Cooper Lighting’s F-Bay Modular Power Supply option is available for use with all F-Bay products. The modular power supply
allows external xture access for safe and easy servicing. There is no need to remove lamps or reectors to disconnect xture
power with F-Bay Modular Power Supply. Access to the individual xture’s power supply allows servicing without turning off
all the xtures, disrupting occupants. F-Bay Modular Power Supply is a time saver in installation – simply plug & power.
12
HBLED
HBLED-LD4-18-N-
UNV-L850-ED2-U
Dimming Driver
Linear LED 5000K
Spacing criterion:
(II) 1.28 x mounting
height, () 0.72 x
mounting height
Lumens: 18818
Input Watts: 151.9W
Effi cacy: 123.9 lm/W
Test Report:
HBLED-LD4-18-N-
UNV-L850-ED2-U.
IES
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Candlepower
Angle Along II 45°Across
15873 15873 15873
15880 15814 15872
15717 15297 15140
15408 14740 12779
14954 12820 9358
14400 9726 5673
13740 7682 1438
12964 3637 394
12077 1084 162
11111 317 144
10003 148 144
8842 149 83
7533 131 53
6151 96 46
4648 62 24
3105 19 21
1651 16 30
441 16 22
0 0 0
Coefficients of Utilization
Effective fl oor cavity re ectance 20%
rc 80%70% 50%30% 10%0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
119 119 119 119 11 6 11 6 11 6 11 6 111 111 111 106 106 106 102 102 102 100
11 2 108 105 102 109 106 103 101 102 100 98 98 96 95 95 93 92 90
105 98 93 89 102 97 92 88 93 89 86 90 87 84 87 85 82 81
98 90 84 79 96 88 83 78 86 81 77 83 79 75 81 77 74 72
92 82 76 70 90 81 75 70 79 73 69 77 72 68 75 71 67 66
86 76 69 64 84 75 68 63 73 67 63 71 66 62 69 65 61 60
81 70 63 58 79 69 63 58 68 62 57 66 61 57 65 60 56 55
76 65 58 53 75 64 58 53 63 57 53 62 56 52 61 56 52 50
72 61 54 49 71 60 54 49 59 53 49 58 52 48 57 52 48 47
68 57 50 45 67 56 50 45 55 49 45 54 49 45 53 48 45 43
64 53 47 42 63 53 47 42 52 46 42 51 46 42 50 45 42 40
3979
0˚ 10˚3
40˚
50˚
70˚
90˚
7959
11938
20˚
80˚
60˚
15917
Zonal Lumen Summary
Zone Lumens% Fixture
0-30
0-40
0-60
0-90
0-180
10076 53.5
13520 71.8
17434 92.6
18818 100.0
18818 100.0
Luminance Data
Angle
in Deg
Average
0-Deg
cd/sm
Average
45-Deg
cd/sm
Average
90-Deg
cd/sm
45
55
65
75
85
25371 713 321
24890 411 227
23502 353 168
19371 111 123
8172 256 321
PHOTOMETRICS
ADF141931
7-13-2016
Specifications and
dimensions subject to
change without notice.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
HBLED
ADF141931
7-13-2016
Ambient
Temperature
TM-21 Lumen
Maintenance
(60,000 hours)
Theoretical
L70
(Hours)
55°C > 84% > 142,000
LUMEN MAINTENANCE
Catalog Number Delivered
Lumens WattsEfficacy
(lm/W)
HBLED-LD4-12-W-UNV-L850-ED1-U 12,505 10
41
20
HBLED-LD4-12-N-UNV-L850-ED1-U 12,156 10
41
17
HBLED-LD4-18-W-UNV-L850-ED2-U 19,358 15
21
27
HBLED-LD4-18-N-UNV-L850-ED2-U 18,818 15
21
24
HBLED-LD4-24-W-UNV-L850-ED2-U 24,002 203 118
HBLED-LD4-24-N-UNV-L850-ED2-U 23,332 203 11 5
HBLED-LD4-30-W-UNV-L850-ED3-U 29,302 228 129
HBLED-LD4-30-N-UNV-L850-ED3-U 28,483 228 125
HBLED-LD4-36-W-UNV-L850-ED3-U 35,944 307 117
HBLED-LD4-36-N-UNV-L850-ED3-U 34,941 307 114
HBLED-LD4-48-N-UNV-L850-ED4-U 46,312401 115
HBLED-LD4-48-W-UNV-L850-ED4-U 48,108 402 120
ENERGY AND PERFORMANCE DATA BY CATALOG NUMBER
Lumen Package Ambient Rating CD or 5LTD Driver Lensed EM Battery HT Option
12,000 55°C 40°C 40°C 40°C NA
18,000 55°C 40°C 40°C 40°C NA
24,000 55°C 40°C 40°C 40°C NA
30,000 55°C 40°C 40°C 40°C NA
36,000 40°C 40°C 35°C* 35°C NA
48,000 40°C 35°C 35°C* 35°C 50°C (17)
*Lens inserts only
AMBIENT RATINGS
Specifications and
dimensions subject to
change without notice.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
SAMPLE N UMBER: HBLED-LD4-18-W-UNV-L850-ED2 - U
Lamp Type
LD4=LED 4.0
LED Lumen Output
12=12,000 Lumens
18=18,000 Lumens
24=24,000 Lumens
30=30,000 Lumens
36=36,000 Lumens
48=48,000 Lumens (15)
48HT=48,000 Lumens, 5 C Ambient (17)
Series (14)
HBLED=LED
High Bay Linear
Voltage (1)
120V=120 Volt
277V=277 Volt
347V=347 Volt (6), (10)
480V=480 Volt (6), (10), (18), (21)
UNV=Universal Voltage 120-277
UNC=Universal Voltage 347/480 (6)
Shielding
[Blank]=None
A=Prismatic Acrylic Lens & Doorframe (8), (9), (11), (20)
CL=Clear Acrylic Lens & Doorframe (8), (11), (20)
A/WG=Acrylic Lens, Wireguard & Doorframe (8), (9), (11), (20)
CL/WG=Clear Lens, Wireguard & Doorframe (8), (11), (20)
AI=Prismatic Acrylic Lens Insert (8), (9)
CLI=Clear Acrylic Lens Insert (8)
FLI=Frosted Lens Insert (8), (9)
POLY125/WG=Polycarbonate Lens, Wireguard and Doorframe (8), (11), (20)
POLY125=Polycarbonate Lens and Doorframe (8), (11), (20)
Distribution
N=Narrow (Aisle)
W=Wide (General)
Options
MP=Modular Power
Receptacle (used for all
Cord or Cord and Plug
options)(3)
Packaging
U=Unit Pack
PALC=Job Pack
In Carton
Options (5)
Emergency
EL7W=7-watt, 120V-277V emergency
battery pack installed (4)
EL14W=14-watt 120V-277V emergency
battery pack installed (4)
GTD2=Bodine Generator Transfer Device (19)
ETS2=IOTA Emergency Transfer Switch (19)
Accessories (order separately)
HBL-SPM=Single Monopoint Hanger w/Hub
FH-1=Fixture Hook
FL-1=Fixture Loop
Y-TOGGLE=Y Mounting Toggle, #2 Cable (8)
(Specify 10' or 30', requires 2 per fixture)
HBAYC-CHAIN/SET/U=(2) V-Hook Hangers, 36" Chain Sets
w/S-Hooks
MPC3=3' Modular Power Cord & Plug (Specify Voltage)
MC6=6' Modular Power Cord
MPC6=6' Modular Power Cord & Plug (Specify Voltage)
MMS=360° or 180° Aisle Motion Sensor with Modular Power
Receptacle (120-277V)
Includes V Hangers for rapid installation
Driver Type
CD=0-10V Dimming
Driver (7), (8)
ED=Electronic Fixed
Output Driver (7)
5LTD=Fifth Light
DALI (7), (8), (13)
Number of Drivers
1=1 Driver (12,000 lumen
version)
2=2 Drivers (18,000 and
24,000 lumen version)
3=3 Drivers (30,000 and
36,000 lumen versions)
4=4 Drivers (48,000 lumen
version)
WG/HBL6-4FT-B=Field Installable, Wireguard for HBLED (12)
ISHH-01=Programming Remote for Integrated Sensor
ISHH-02=Personal Control Remote for Integrated Sensor
CCT
L835=3500K
L840=4000K
L850=5000K
Motion Sensors
MS=360° or 180° Motion Sensor
Installed, (specify voltage) (2)
SVPD3=Integrated occupancy and daylight
dimming sensor, 1200 sq. ft. coverage (16), (20)
NOTES: (1) Voltage must be specified when ordered with plugs or emergency drivers . (2) When ordering MS option, specify as UNV (for 120 or 277V), 347 or 480V. (3) Requires use of MC or MPC cord accessories,
specify voltage for plugs (MP). (4) With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100
lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (5) EM options available in 0°C - 40°C ambient. (6) Not available with dual switching. (7) Lumen output will vary
depending on dimming or fixed output drivers. Refer to IES files for deliveried lumens. (8) Rated for 40°C ambient. (9) Not available with narrow distribution. (10) EM options not available with 30,000, 36,000 or 48,000
lumen configuration at 347V or 480V. (11) Not available with 36,000 or 48,000 lumen configuration. (12) Not available with lens insert options AI, CLI and FLI or doorframe options A , CL and POLY125. (13)
5LTD available with
12,000, 18,000 and 30,000 lumen packages only. (14) DesignLights Consortium™ Qualified and classified for DLC Standard (some models are not DLC qualified), refer to www.designlights.org for details. (15) 40ºC max.
ambient rating. (16) Integrated sensor limited to 36,000 lumens. (17) HT lumen package not available with 347 or 480V, emergency, dimming, or lensed options. (18) 480V not for use with impedance grounded systems
or corner grounded systems (commonly known as Three Phase Three Wire Delta, Three Phase High Leg Delta and Three Phase Corner Grounded Delta systems). (19) Used to transfer fixture to secondary power
source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under emergency power. (20) I ntegrated sensor not compatible with door
frame. (21) Only for use with 480V Wye systems. Per NEC, not for use with ungrounded systems, impedance grounded systems or corner grounded systems (commonly known as Three Phase Three Wire Delta, Three
Phase High Leg Delta and Three Phase Corner Grounded Delta systems).
Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information.
ORDERING INFORMATION
Catalog No. Wt.
HBLED-LD4-12 19 lbs.
HBLED-LD4-18 22 lbs.
HBLED-LD4-24 22 lbs.
HBLED-LD4-30 24 lbs.
HBLED-LD4-36 24 lbs.
SHIPPING DATA
HBL E D
ADF141931
7-13-2016
Specifications and
dimensions subject to
change without notice.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
HBLED
ADF141931
7-13-2016
Programming Remote
ISHH-01
To Set Output
1. R
aise, Lower or Press Min.
5 0, 75, Max.
2. T
o save press SET
3. S
elect Occ or Un Occ
Raise/
Lower
Time
Out
5
10
15
20
HI
LO
ES
SET
Occ
50
MIN
Un
Occ
MAX
75
Personal Remo te
ISHH-02
Raise /
Lower
SCENE
MAX
75
50
MIN
Un
Occ
ES
Occ
To Selec t Scene s
Press the S CENE button .
The ligh ti ng wi ll ad just to
stor ed light level s. .
Side View
0
6.1m
[20 ft.]
9.1m
[30 ft.] 12.2m
[40 ft.]
9.1m
[30 ft.]
6.1m
[20 ft.]
3m
[10 ft.]
012.2m
[40 ft.]
9.1m
[30 ft.]
6.1m
[20 ft.]
3m
[10 ft.]
SVPD3 Coverage Pattern
Light Level
100
0
Light Level
(DO)
Daylight Level
(DO)
Daylight Level
Timeout Value
(ES)
Energy Saver
Light Level
OccupiedUnoccupiedOccupiedUnoccupied
Energy Savings
Opportunities
(DU)
Unoccupied Level
Default daylight harvesting set using 36,000 lumen unit at 30 ft. mounting height, 20 ft. spacing for 50 footcandles.
INTEGRATED SENSOR

Navigation menu