Limit Switches Catalog, 9007CT0501 1000296252 Catalog 1
2016-07-29
: Pdf 1000296252-Catalog 1 1000296252-Catalog_1 B2 unilog
Open the PDF directly: View PDF .
Page Count: 247 [warning: Documents this large are best viewed by clicking the View PDF Link!]
Building a New Electric World
Limit Switches
File 9007 / XC
CONTENTS
Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Applications by Market Segment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Osiswitch® XC Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Osiswitch Miniature Snap Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Osiswitch Miniature Limit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Osiswitch Compact Limit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Osiswitch Classic Limit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Class 9007 Industrial Snap Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Class 9007 Miniature Limit Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Class 9007AW Heavy Duty Industrial Limit Switches . . . . . . . . . . . . . . . 161
Class 9007C Heavy Duty Industrial Limit Switches . . . . . . . . . . . . . . . . . 162
Class 9007T and FT Severe Duty Mill and Foundry Limit Switches . . . . 214
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches . 226
Catalog
March
07
3
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Table of Contents
Osiswitch® Limit Switches
Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Osiswitch® Miniature Snap Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Osiswitch® Miniature, Metal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Osiswitch® Miniature, Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Osiswitch® Compact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Osiswitch® Compact, Metal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Osiswitch® Compact, Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Osiswitch® Compact, Metal and Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Osiswitch® Compact, Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Osiswitch® Compact, Metal and Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Osiswitch® Compact with Manual Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Osiswitch® Classic, Metal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041 . . . . . . . . . . . . . 98
Osiswitch® Classic, Plastic, Conforming to CENELEC EN 50041 . . . . . . . . . . . 126
Osiswitch® Classic, For Hoisting, Mechanical Handling, and Conveyer Belt Shift
Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Osiswitch® Classic, For Hoisting and Material Handling . . . . . . . . . . . . . . . . . . 138
Osiswitch® Classic, For Material Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
4
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Selection Guide
Osiswitch® Universal
Design Miniature Compact
Catalog number XCMD XCKD XCKP XCKT
Enclosure Metal Plastic, double insulated
Features Mounting by the body or by the head
Modularity Head, body and connection modularity Head and body modularity
CENELEC conformity —EN 50047 EN 50047 compatible
Body dimensions (w x h x d),
mm (in.)
30 x 50 x 16
(1.18 x 1.97 x 0.63)
31 x 65 x 30
(1.22 x 2.56 x 1.18)
58 x 51 x 30
(2.28 x 2.01 x 1.18)
Head
Linear movement (plunger)
Rotary movement (lever)
Rotary movement, multi-directional
Same heads for ranges XCMD, XCKD, XCKP and XCKT
Contact
blocks
2 snap action contacts with
positive opening operation N/C + N/O; N/C + N/C N/C + N/O
3 snap action contacts with
positive opening operation N/C + N/C + N/O N/C + N/C + N/O; N/C + N/O + N/O —
4 snap action contacts with
positive opening operation N/C + N/C + N/O + N/O —
2 slow break contacts with
positive opening operation N/C + N/O break before make N/C + N/O break before make; N/O + N/C make before break;
N/C + N/C simultaneous
2 slow break contacts —N/O + N/O simultaneous
3 slow break contacts with
positive opening operation
N/C + N/C + N/O break before
make
N/C + N/C + N/O break before make;
N/C + N/O + N/O break before make —
Insulation voltage (Ui) / thermal current
(Ithe)
Pre-cabled
2 contacts: 400 V/6 A
3 contacts: 400 V/4 A
4 contacts: 400 V/3 A
Screw terminal
2 contacts: 500 V/10 A
3 contacts: 400 V/6 A
Screw terminal
2 contacts:
500 V/10 A
Connector
Integral M12, 4-pin:
250 V/3 A
Integral M12, 5-pin:
60 V/4 A
Remote 7/8" 16UN:
250 V/6 A
Integral M12, 5-pin:
60 V/4 A
Integral M12, 4-pin:
250 V/3 A —
Degree of protection
NEMA Types 1, 2, 4X, 6, 12
IP 66, IP 67, IP 68,
IK 06
NEMA Types 1, 2, 4, 6, 12, 13
IP 66, IP 67,
IK 06
NEMA Types 1, 2, 4, 6, 6P, 12, 13
IP 66, IP 67,
IK 04
NEMA Types 1, 2, 4, 6, 12, 13
IP 66, IP 67,
IK 04
Connection
Screw terminals —1 entry for ISO M16 or M20, PG 11, PG 13 conduit thread or
1/2" NPT, PF 1/2
2 entries for ISO M16 or PG 11
conduit thread or 1/2" NPT
(using adapter
Pre-cabled Integral: No
Remote: Yes —
Connector Integral or remote M12 or
remote 7/8" 16UN Integral M12 —
Page 44 56 and 60 62 and 66 68
5
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Selection Guide
Osiswitch® Optimum and Application
Design Miniature Optimum Compact Application: with manual reset
Catalog number XCMN XCDR XCPR XCTR
Enclosure Plastic, double insulated Metal Plastic, double insulated
Features Mounting by the body or by the
head Mounting by the body
Modularity —
CENELEC conformity —
Body dimensions (w x h x d),
mm (in.)
30 x 50 x 16
(1.18 x 1.97 x 0.63)
31 x 65 x 30
(1.22 x 2.56 x 1.18)
58 x 51 x 30
(2.28 x 2.01 x 1.18)
Head
Linear movement (plunger)
Rotary movement (lever)
Rotary movement, multi-
directional
Linear movement (plunger)
Rotary movement (lever)
Same heads for ranges XCDR, XCPR and XCTR
Contact
blocks
2 snap action contacts with
positive opening operation N/C + N/O
3 snap action contacts with
positive opening operation —
4 snap action contacts with
positive opening operation —
2 slow break contacts with
positive opening operation —N/C + N/O break before make
2 slow break contacts —
3 slow break contacts with
positive opening operation —
Insulation voltage (Ui) / thermal current (Ithe)
Screw terminal
2 contacts:
400 V/6 A
Screw terminal
2 contacts:
500 V/10 A
Connector —
Degree of protection
NEMA Types 1, 2, 13
IP 65,
IK 04
IP 66, IP 67,
IK 04
Connection
Screw terminals —1 entry for ISO M20 or PG 13 conduit thread or 1/2" NPT
2 entries for ISO M16 or PG 11
conduit thread or 1/2" NPT
(using adapter)
Pre-cabled Ye s —
Connector
—
Page 52 76 78 80
6
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Selection Guide
Osiswitch® Classic
Design Classic
Catalog number XCKM XCKL XCKJ
Enclosure Metal
Features 3 conduit entries Fixed or plug-in body, -40 °C (-40 °F)
or +120 °C (+248 °F) versions
Modularity Head + Body + Operator
CENELEC or DIN conformity —EN 50041
Body dimensions (w x h x d),
mm (in.)
63 x 64 x 30
(2.48 x 2.52 x 1.18)
52 x 72 x 30
(2.05 x 2.83 x 1.18)
40 x 77 x 44 (1.57 x 3.03 x 1.73)
42.5 x 84 x 36 (1.67 x 3.31 x 1.42)
Head
Linear movement (plunger)
Rotary movement (lever)
Rotary movement, multi-directional
Contact
blocks
2 snap action contacts with
positive opening operation N/C + N/O; N/C + N/C N/C + N/O N/C + N/O; N/C + N/C
3 snap action contacts with
positive opening operation N/C + N/C + N/O; N/C + N/O + N/O
C/O snap action contacts —2 C/O
C/O slow break contacts —
2 slow break contacts with
positive opening operation
N/C + N/O break before make
N/O + N/C make before break
N/C + N/C simultaneous
2 slow break contacts N/O + N/O simultaneous
3 slow break contacts with
positive opening operation N/C + N/C + N/O break before make; N/C + N/O + N/O break before make
Insulation voltage (Ui) / thermal current (Ithe)
Screw terminal
2 contacts: 500 V/10 A
3 contacts: 400 V/6 A
—
Connector
Integral M12, 5-pin: 60 V/4 A
Integral 7/8" 16UN: 250 V/6 A
Degree of protection
NEMA Types 1, 2, 4, 6, 6P, 12, 13
IP 66,
IK 06
NEMA Types 1, 2, 4, 12
IP 66
IK 07
Connection
Screw terminals
(cable entry)
3 entries for ISO M20 or PG 11 conduit
thread or 1/2" NPT
1 entry incorporating cable entry or tapped
1/2" NPT
1 entry for ISO M20 or PG 13 conduit
thread or 1/2" NPT
Connector ——Integral M12
or 7/8" 16UN
Page 82 82 98
7
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Selection Guide
Osiswitch® Classic, Application, and Miniature Snap Switches
Design Classic
Application: for
installations requiring
electrical redundancy
Application: for lifting
and materials handling
equipment or very
severe applications
Sub-miniature,
miniature: applications
requiring high
precision and a low
operating force
Catalog number XCKS XCKML XCR, XC1AC XEP, XCO
Enclosure Plastic, double insulated Metal Metal or polyester Plastic
Features —2 sets of contacts —Depending on type
Modularity Head + Body + Operator Fixed composition
Depending on type, fixed
composition or contact and
operator
CENELEC or DIN conformity EN 50041 —
Body dimensions (w x h x d),
mm (in.)
40 x 72.5 x 36
(1.57 x 2.85 x 1.42)
72 x 81 x 36
(2.83 x 3.19 x 1.42) Depending on type DIN 41635, depending on
type
Head
Linear movement (plunger)
Rotary movement (lever)
Rotary movement, multi-directional
Linear movement (plunger)
Rotary movement (lever) Linear movement (plunger)
Contact
blocks
2 snap action contacts with
positive opening operation N/C + N/O; N/C + N/C 2 x N/C + N/O contact
blocks Depending on type —
3 snap action contacts with
positive opening operation N/C + N/C + N/O; N/C + N/O + N/O —
C/O snap action contacts 2 C/O —Depending on type 1 single-pole contact
C/O slow break contacts —Depending on type —
2 slow break contacts with
positive opening operation
N/C + N/O break before make
N/O + N/C make before break
N/C + N/C simultaneous
2 x N/C + N/O break before
make contact blocks Depending on type —
2 slow break contacts N/O + N/O simultaneous —
3 slow break contacts with
positive opening operation
N/C + N/C + N/O break before make
N/C + N/O + N/O break before make —
Insulation voltage (Ui) / thermal current (Ithe)
Screw terminal
2 contacts: 500 V/10 A
3 contacts: 400 V/6 A
Screw terminal
2 contacts: 500 V/10 A Depending on type
—
Degree of protection IP 65
IK 03
NEMA Types:
1, 2, 4, 6, 6P, 12, 13
IP 66
IK 06
Depending on type:
IP 66, IK 05;
IP 65, IK 05; or
IP 54, IK 05
Depending on type
Connection
Screw terminals
(cable entry)
1 entry for ISO M20 or
PG 13 conduit thread
3 entries for ISO M20 or
PG 13 conduit thread; or
PG 13 to 1/2” NPT with
adapter
Depending on type: 1 or
3 entries for ISO M20 or
PG 13 conduit thread
Depending on type: by tags
or pre-wired
Connector —
Page 126 82 136 and 144 26
8
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Selection Guide
Class 9007 Industrial Snap Switches and Miniature Industrial Switches
Design Industrial Snap Switch Miniature Switch Miniature Enclosed Reed Heavy Duty Industrial,
Precision Oiltight
Catalog Number Prefix 9007A
9007C
9007MS
9007ML 9007XA 9007AW
Description Industrial snap switches
with or without operators
Miniature enclosed switches,
potted and pre-wired with cable.
Unique rotary head. 9007 ML has
double break contacts.
Miniature enclosed switches,
potted and pre-wired with cable.
Reed contacts for superior low-
energy switching.
Precision oil tight enclosed
switches with unique features,
micrometer adjustable and low
temperature operation.
Enclosure Material Plastic Metal bodies, metal head Metal bodies, metal head Metal bodies, metal heads
Enclosure Rating None NEMA: Types 1, 2, 4, 6, 6P, 12, 13
IEC: IP67 NEMA: Types 1, 2, 4, 6, 6P, 12, 13 NEMA: Types 1, 2, 4, 6, 6P, 12, 13
Approximate Body Dimensions,
mm (in.)
29.0 x 63.5 x 21.0
(1.14 x 2.5 x 0.83)
40.1 x 44.4 x 15.8
(1.58 x 1.75 x 0.62)
40.1 x 44.2 x 16.0
1.58 x 1.74 x 0.63)
36.6 x 98.5 x 63.5
(1.44 x 3.88 x 2.5)
Heads Linear Linear or Rotary Linear or Rotary Linear or Rotary
Contact Blocks
N.C. + N.O. snap action X X N.O. or N.C. X
N.C. + N.O. break before make,
slow break
N.O. + N.C. make before break,
slow break
N.C. + N.C. simultaneous,
slow break
N.O. + N.O. simultaneous,
slow break
C/O snap action
C/O slow break
N.C. + N.C. 2-step, slow break
N.O. + N.O. 2-step, slow break
N.C. + N.C. snap action
N.O. + N.C. slow make, slow break
Cabling Pre-wired cable,
M12 Connector option available. Pre-wired cable.
Temperature Range -65 to +221 °F
(-54 to +105 °C)
-40 to +221 °F
(-40 to +105 °C)
-20 to + 140 °F
(-29 to +60 °C)
0 to +185 °F (-17.8 to 85 °C)
Lever operated:
-65 to +185 °F (-54 to 85 °C)
Additional Features A variety of operators are
available, page 152
Bottom or side cable entry.
Full range of operating heads,
page 156.
Bottom cable entry.
Three common operating heads,
page 160.
Most common operating heads.
Micrometer adjustable push rod
plunger. Uses 9007C levers,
page 190.
9
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Selection Guide
Class 9007 Type C Heavy Duty Industrial
Applications Material handling—mechanical conveying, automotive, machine tool, packaging
Hazardous application
locations: gases (explosion),
dust environment.
Design Standard body type 9007C••••• Standard body reed
contacts
Compact body type
9007C52••
Hazardous location body type
9007CR••••
Catalog number
9007C54•••
9007C62•••
9007C68•••
9007C66•••
9007C84•••
9007C86••• 9007C52••
9007CR53••
9007CR61••
9007CR65••
9007CR67••
Enclosure Metal, diecast, zinc alloy
Features Plug-in body Non-plug-in body
Factory modifications (Forms) See pages 176 to 180
Modularity Head + body + lever
Conforming to standards
NEMA 250,
EN 60947-1, EN 60947-5-1,
IEC 60947, UL 508, C22-2-14-95,
e conformity documentation
NEMA 250,
EN 60947-1, EN 60947-5-1,
IEC 60947, UL 508, C22-2-14-95,
e conformity documentation
Product certifications UL, CSA, e
Body dimensions
(w x h x d), mm (in.)
with rotary head
39 x 102 x 45 (1.54 x 4.02 x 1.77) 39 x 80 x 45 (1.54 x 3.15 x 1.77) 69 x 156 x 53 (2.72 x 6.14 x 2.10)
Head
Linear movement (plunger)
Rotary movement (lever)
Multi-directional movement (wobble stick, cat whisker)
Contact
blocks
Snap action
contacts
9007C54••• 1 N.O. + 1 N.C.
Reed contacts
1N.O. or 1N.C. 1 N.O. + 1 N.C.
9007CR53•• 1 N.O. + 1 N.C.
9007C62••• 2 N.O. + 2 N.C. 9007CR61•• 2 N.O. + 2 N.C.
9007C68••• 2 N.O. + 2 N.C.
neutral position 9007CR65•• 2 N.O. + 2 N.C.
neutral position
9007C66••• 2 N.O. + 2 N.C.
two stage 9007CR67•• 2 N.O. + 2 N.C.
two stage
Direct opening
(positive opening)
9007C•••• Y1561 Plunger and lever heads only
Single pole only
9007C•••• Y1561
Single pole only
9007CR•••• Y1561
Single pole only
Rated insulation voltage 600 V —
Insulation voltage (Ui)—
top half of body
600 V
Except: 9007CO62, 9007CO66, 9007CO68 (Ui = 250 V)
and 9007C84, 9007C86 (Ui = 125 V)
600 V
600 V
Except: 9007CR63, 9007CR65,
9007CR67 (Ui = 250 V)
Thermal current (Ithe)—
top half of body
10 A
Excepted: 9007CO84, 9007CO86 (2.5 A) 10 A 10 A
Degree of protection IP 67 conforming to IEC 60529,
NEMA Types 2, 4, 6, 6P, 12, 13
IP 67 conforming to IEC 60529
NEMA Types 2, 4, 6, 6P, 12, 13, NEMA Types 2, 4, 6P, 7, 9, 13
Connection (1)
Cable entry or connector
Depending on model: 1/2"-14 NPT,
M20 x 1.5 ISO cable entry,
5-pin mini connector.
Cable entry or connector
Depending on model: 1/2"-14 NPT,
M20 X 1.5 ISO cable entry,
5 pin mini connector.
Cable entry or connector
Depending on model: 1/2"-14 NPT,
M20 X 1,5 ISO cable entry,
3/4 14 NPT available.
Page 164 172 198
1. A wide range lof connectors are available. Contact your local field office.
10
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Selection Guide
Severe Duty Mill and Foundry Switches
Applications Mill Mill Mill Mill
Design 9007T
Convertible sequence
L100
Fixed sequence
L14 Single Cable Pulls
Fixed sequence
L525 Belt Conveyor
Fixed sequence
Catalog number 9007T••• L100••• L14 L525
Enclosure Metal Metal Metal Metal
Features Extra heavy duty contact
ratings
Extra heavy duty contact
ratings
Extra heavy duty
contact ratings
Extra heavy duty
contact ratings
Factory modifications (Forms) Page 221 Page 237 Page 237 Page 237
Conforming to standards NEMA A600 UL508 NEMA A600 UL508 NEMA A600 UL508 NEMA A600 UL508
Product
Product certifications UL Listed, CSA Certified UL Listed, CSA Certified UL Listed, CSA Certified UL Listed, CSA Certified
Body dimensions (w x h x d), mm (in.)
surface mounting
58.7 x 114.3 x 64.5
(2.31 x 4.5 x 2.54)
58.7 x 126 x 53.3
(2.31 x 4.95 x 2.10)
58.7 x 126 x 53.3
(2.31 x 4.95 x 2.10)
58.7 x 126 x 53.3
(2.31 x 4.95 x 2.10)
Head Rotary movement (lever) Rotary movement (lever) Rotary movement (lever) (3) Rotary movement (lever) (3)
Contact
blocks
Snap action contacts (1) 1 N.C. + 1 N.O. 1 N.C. + 1 N.O. 1 N.C. + 1 N.O. 1 N.C. + 1 N.O.
Sequences Convertible Fixed Fixed Fixed
Rated insulation voltage 600 V 600 V 600 V 600 V
Thermal current (Ithe) 20 A ac/dc 20 A ac, 5 A dc 20 A ac, 5 A dc 20 A ac, 5 A dc
Degree of protection NEMA Types 1, 2, 4, 12, 13
IP65, 66, 67
NEMA Types 1, 4, 13
IP65, 66
NEMA Types 1, 4, 13
IP65, 66
NEMA Types 1, 4, 13
IP65, 66
Connection (2)
Cable entry or connector
1/2" NPT
(metric available)
Cable entry or connector
1/2" NPT
(metric available)
Cable entry or connector
1/2" NPT
(metric available)
Cable entry or connector
1/2" NPT
(metric available)
Presentation, Applications and Characteristics Page 216 Page 228 Page 232 Page 233
Interpretation of Catalog Numbers Page 239 Page 239 Page 239 Page 239
1. For other contact options see page 216.
2. A wide range lof connectors are available. Contact your local field office.
3. Lever arms are optional and must be ordered separately.
11
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Selection Guide
Severe Duty Mill and Foundry Switches
Applications Foundry Foundry Mill and Foundry
Design 9007FT
Convertible sequence
L300
Fixed sequence
L2153 Dual Pull Stop
Fixed sequence
Catalog number 9007FT••• L300••• L2153
Enclosure Metal Metal Metal
Features Designed specifically for rough foundry
applications
Designed specifically for
rough foundry applications Extra heavy duty contact ratings
Factory modifications (Forms) Page 221 Page 237 Page 237
Conforming to standards NEMA A600 UL508 NEMA A600 UL508 NEMA A600 UL508
Product
Product certifications UL Listed, CSA Certified UL Listed, CSA Certified UL Listed, CSA Certified
Body dimensions (w x h x d), mm (in.)
surface mounting
58.7 x 114.3 x 86.6
(2.31 x 4.5 x 3.41)
58.7 x 126 x 53.3
(2.31 x 4.95 x 2.10)
58.7 x 126 x 53.3
(2.31 x 4.95 x 2.10)
Head Rotary movement (lever) Rotary movement (lever) Rotary movement (lever) (2)
Contact
blocks
Snap action contacts f1 N.C. + 1 N.O. 1 N.C. + 1 N.O. 1 N.C. + 1 N.O.
Sequences Convertible Fixed Fixed
Rated insulation voltage 600 V 600 V 600 V
Thermal current (Ithe) 20 A ac/dc 20 A ac, 5 A dc 20 A ac, 5 A dc
Degree of protection NEMA Types 1, 2, 4, 12, 13
IP65, 66, 67
NEMA Types 1, 4, 13
IP65, 66
NEMA Types 1, 4, 13
IP65, 66
Connection (1)
Cable entry or connector
1/2" NPT
(metric available)
Cable entry or connector
1/2" NPT
(metric available)
Cable entry or connector
1/2" NPT
(metric available)
Presentation, Applications and Characteristics Page 218 Page 230 Page 232
Interpretation of Catalog Numbers Page 239 Page 239 Page 239
1. A wide range lof connectors are available. Contact your local field office.
2. Lever arms are optional and must be ordered separately.
12
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Selection Guide
Applications by Market Segment
Crane and Hoist
•Overhead Cranes
•Transport Systems
Mill and Foundry
•Iron and Steel
•Cement and Glass
Process Machinery
•Machine Tools
•Plastic, Rubber, Molding
•Printing
•Textile
•Pulp, Paper, Wood
Material Handling
•Conveyance
•Carousels
•Automatic Storage/Retrieval
Packaging Machinery
•Packaging Machines
•Shrink Wrap
Food and Beverage Machinery
•Bottling
•Canning
Simple Machines
•Transportation Wash
•Light Handling
•Assembly Stations
•General Purpose
Electric Lifts
•Lifting Platforms
•Elevators
•Escalators
XCKP
XCKT
XCKD
XCKM
XCKL
XCKML
XCMD
9007MS/ML
9007XA
XCKS
NOTE: Special electrical options available for:
• Low current switching for programmable controllers
• Hazardous locations
13
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Selection Guide
Applications by Market Segment
9007AW XCKJ
9007C
L100/L300
9007T/FT
XCR
9007CLS
14
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Selection Guide
Osiswitch® XC Product Overview
Introduction Electromechanical detection
Limit switches are used in all automated installations and also in a wide variety of applications,
due to the numerous advantages inherent to their technology.
They transmit data to the logic processing system regarding:
• presence/absence
• passing
• positioning
• end of travel
Simplicity of installation, advantages
From an electrical viewpoint
• galvanic separation of circuits,
• models suitable for low power switching, combined with good electrical durability,
• very good short-circuit withstand in coordination with appropriate fuses,
• total immunity to electromagnetic interference,
• high rated operational voltage.
From a mechanical viewpoint
• N/C contacts with positive opening operation,
• high resistance to the different ambient conditions encountered in industry (standard tests
and specific tests under laboratory conditions),
• high repeat accuracy, up to 0.01 mm on the tripping points.
Detection movements
• Linear movement
(plunger)
• Rotary movement (lever) • Multi-directional movement
Terminology Rated value of a quantity • This replaces the term “nominal value”.
• It is the fixed value for a specific function.
Utilization categories
• AC-15 replaces AC-11: control of an electromagnet on a.c.,
test 10 le/le.
• AC-12: control of a resistive load on a.c. or static load isolated
by opto-coupler.
• DC-13 replaces DC-11: control of an electromagnet on d.c.,
test le/le.
Switching capacity
• Ithe is no longer a rated value but a conventional current used
for heating tests.
Example: for category A300 the corresponding operational
current, le maximum, is 6 A-120 V or 3 A-240 V, the equivalent
Ithe being 10 A.
Positive opening travel
• Minimum travel from the initial movement of contact actuator
to the position required to accomplish positive opening
operation.
Positive opening force • The force required on the contact actuator to accomplish
positive opening operation.
Positive opening
operation
• A limit switch complies with this specification when all the
closed contact elements of the switch can be changed, with
certainty, to the open position (no flexible link between the
moving contacts and the operator of the switch, to which an
actuating force is applied).
• All limit switches incorporating either a slow break contact
block or a snap action N/C + N/O (form Zb), N/C + N/O + N/O,
N/C + N/C + N/O, N/C + N/C + N/O + N/O contact block are
positive opening operation, in complete conformity with
standard IEC 60947-5-1 Appendix K.
Tripped Unactuated Tripped Unactuated Tripped Unactuated
15
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Selection Guide
Osiswitch® XC Product Overview
Contact blocks Snap action contacts
• Snap action contacts are characterized by different tripping and reset points (differential
travel).
• The displacement speed of the moving contacts is not related to the speed of the operator.
• This feature ensures satisfactory electrical performance in applications involving low speed
actuators.
Unactuated state Approach travel Contact change of state Positive opening
Slow break contacts
• Slow break contacts are characterized by identical tripping and resetting points.
• The displacement speed of the moving contacts is equal, or proportional, to the speed of
the operator—which must not be less than 0.1 m/s, or 6 m/minute (0.33 ft/s, or
19.68 ft/minute).
• The opening distance also depends on the distance traveled by the operator.
Electrical durability for normal loads
• Normally, for inductive loads, the current value is less than 0.1 A (sealed), i.e. values of 3 to
40 VA sealed and 30 to 1000 VA inrush, depending on the voltage.
For this type of application the electrical durability exceeds 10 million operating cycles.
Application example: XCKJ161 + LC1D12•••• (7 VA sealed, 70 VA inrush).
Electrical durability = 10 million operating cycles.
Switching capacity
1. Normal industrial PLC input type 1
2. Normal industrial PLC input type 2
3. Switching capacity conforming to IEC 60947-5-5, utilization category AC-15, DC-13
A300 240 V 3 A B300 240 V 1.5 A
Q300 250 V 0.27 A R300 250 V 0.13 A
4. Switching capacity conforming to IEC 60947-5-1, utilization category AC-15, DC-13
A300 120 V 6 A B300 120 V 3 A
Q300 125 V 0.55 A R300 125 V 0.27 A
Electrical durability for small loads
• The use of limit switches with programmable controllers is becoming more common.
• With small loads, limit switches offer the following levels of reliability:
• failure rate of less than 1 for 100 million operating cycles using snap action contacts
(contacts XE2SP).
• failure rate of less than 1 for 20 million operating cycles using slow break contacts (contacts
XE•NP and XE3SP).
• failure rate of less than 1 for 5 million operating cycles using contacts XCMD.
Range of use
Standard contacts
Continuous service
(frequent switching)
XE2SP2151, P3151
XE2NP••••
Contacts of XCMD, XE3•P••••
Gold flashed contacts
on resistive load
Occasional service
Infrequent switching, y1 operating cycle/day
and/or corrosive atmosphere
(1) 1. Usable up to 48 V/10 mA.
13
21
14
22
13
21
14
22
13
21
14
22
13
21
14
22
21 22
13 14
21 22
13 14
1 mA 2
mA
3 mA 6 mA 10
mA
5
6
10
8
20
60
100
15
150
200
500
2 A 3A 6A 10 A 1 A
120
240
24
1
2
3
4
V
48
(1)
Insulation voltage limit
Heating limit (Ithe)
Inductive
zone
16
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Selection Guide
Osiswitch® XC Product Overview
Principle Innovation through modularity
•The Miniature design XCMD and Compact design XCKD, XCKP and XCKT
product range family benefits from the
Osi
concept™ principle:
O
ffering
s
implicity
through
i
nnovation.
•A first in worldwide detection for improving productivity.
A complete offer for resolving the most commonly encountered detection
problems:
— product selection simplified,
— product availability simplified,
— installation and setup simplified,
— maintenance simplified.
Heads
•A single metal operating head type for the Miniature design XCMD and Compact
design XCKD, XCKP and XCKT ranges.
.
•Interchanging of heads achieved by simple operation of forked metal latch.
•Adjustable in 3 planes:
All the heads can be adjusted in
15° steps throughout 360°, in
relation to the body.
All the levers can be adjusted in 15° steps throughout
360°, in relation to the horizontal axis of the head.
15˚
15˚
15˚
17
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Selection Guide
Osiswitch® XC Product Overview
Principle (continued) Cable entries
The cable entries for Compact design XCKD and XCKP switches enable:
•simple cabling due to unrestricted access to contacts
•simple adaptation to the various worldwide markets
6 models are available:
•ISO M16 x 1.5
•PG 11
•ISO M20 x 1.5
•PG 13
•1/2" NPT
• PF 1/2 (G 1/2)
Each model is available in metal or plastic, suited for compact design XCKD or XCKP,
respectively. A connector version is also available.
Connection components
•The miniature XCMD range allows interchangeability of these pre-cabled
connection components:
— 1/4 turn is all that is required to remove the connection component on XCMD
bodies with 2 and 3 contacts,
— 6 alternative cable lengths are available.
•The miniature XCMD range also includes an integral or remote connector solution.
Contact block or body with contacts
•2 and 3 snap action and slow break contact blocks, with positive opening
operation, are interchangeable between the Compact design XCKD and XCKP
and Classic XCKJ, XCKS, XCKM and XCKL ranges.
•For the Miniature design XCMD range, the contacts are an integral part of the
body:
— 2 and 3 snap action and slow break contacts, with positive opening operation,
and interchangeable connection component,
— 4 snap action contacts, with positive opening operation, with monolithic body
and connection components.
1/4 turn
18
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Selection Guide
Osiswitch® XC Product Overview
Contact blocks (continued) Functional diagrams of snap action contacts
Example: N/C + N/O
A—Maximum travel of the operator in mm or degrees.
B—Tripping travel of contact.
C—Resetting travel of contact.
D—Differential travel = B–C.
P—Point from which positive opening is assured.
Linear movement (plunger)
1—Resetting point of contact.
2—Tripping point of contact.
A—Maximum travel of the operator in mm.
B—Tripping travel of contact.
C—Resetting travel of contact.
D—Differential travel = B–C.
P—Point from which positive opening is assured.
Rotary movement (lever)
1—Resetting point of contact.
2—Tripping point of contact.
A—Maximum travel of the operator in degrees.
B—Tripping travel of contact.
C—Resetting travel of contact.
D—Differential travel = B–C.
P—Point from which positive opening is assured.
Functional diagrams of slow break contacts
Example: N/C + N/O break before make
A—Maximum travel of the operator in mm or degrees.
B—Tripping and resetting travel of contact 21-22.
C—Tripping and resetting travel of contact 13-14.
P—Point from which positive opening is assured.
Linear movement (plunger)
1—Tripping and resetting points of contact 21-22.
2—Tripping and resetting points of contact 13-14.
A—Maximum travel of the operator in mm.
B—Tripping and resetting travel of contact 21-22.
C—Tripping and resetting travel of contact 13-14.
P—Positive opening point.
Rotary movement (lever)
1—Tripping and resetting points of contact 21-22.
2—Tripping and resetting points of contact 13-14.
A—Maximum travel of the operator in degrees.
B—Tripping and resetting travel of contact 21-22.
C—Tripping and resetting travel of contact 13-14.
P—Positive opening point.
B
C
0D
21 - 22
13 - 14
21 - 22
13 - 14
A
P
Tr i p p i n g
Resetting
D
B
A
0
1
2
P
C
max.
A
B
D
P
2
1
C
21 - 22
13 - 14
A
0
BP
C
Tripping
and
Resetting
B
C
A
0
1
2
P
max.
A
C
B
P
12
19
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Selection Guide
Osiswitch® XC Product Overview
Contact blocks (continued) Contact connections
XE2•P screw clamp terminal connections
XE3•P screw clamp terminal connections
•Tightening torque:
— minimum tightening torque ensuring the nominal characteristics of the contact:
0.8 N•m (7.08 lb-in)
— maximum tightening torque without damage to the
terminals: 1.2 N•m (10.62 lb-in) for XE2•P,
1 N•m (8.85 lb-in) for XE3•P
•Connecting cable: cable preparation lengths:
— for XE2• P, L = 22 mm (0.87 in.)
— for XE2•P3•••, L = 45 mm (1.77 in.)
— for XE3•P:
L = 14 mm (0.55 in.)
L1 = 11 mm (0.43 in.)
Mounting Sweep of connecting cable
1. Recommended
2. To be avoided
Position of cable entry
1. Recommended
2. To be avoided
Type of cam
1. Recommended
2. To be avoided
Mounting limit switches by the head
1. Recommended
2. Forbidden
Types XCKD, XCKP and XCKT, XCMD and XCMN
L
L L1
12
12
30 30
12
122
20
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Selection Guide
Osiswitch® XC Product Overview
Setup Tightening torque
• The minimum torque is that required to ensure correct operation of the switch.
• The maximum torque is the value which, if exceeded, will damage the switch.
Range Item Torque, N•m (lb-in)
Min. Max.
Compact design XCKD, XCKP, XCKT Cover 0.8 (7.08) 1.2 (10.62)
Mounting screw for lever on rotary head 1 (8.85) 1.5 (13.28)
Miniature design XCMD, XCMN ———
Mounting screw for lever on rotary head 1 (8.85) 1.5 (13.28)
Classic design XCKJ Cover 1 (8.85) 1.5 (13.28)
Mounting nut for lever on rotary head 1 (8.85) 1.5 (13.28)
Classic design XCKS Cover 0.8 (7.08) 1.2 (10.62)
Mounting nut for lever on rotary head 1 (8.85) 1.5 (13.28)
Classic design XCKM, XCKML, XCKL Cover 0.8 (7.08) 1.2 (10.62)
Mounting nut for lever on rotary head 1 (8.85) 1.5 (13.28)
Types XCKD, XCKP, XCKT, XCMD
• Adjustable in 3 planes:
All the heads can be adjusted in 15° steps
throughout 360°, in relation to the body.
All the levers can be adjusted in 15° steps throughout 360°, in
relation to the horizontal axis of the head.
Type XCKJ
• Adjustable through 360° in 5° steps, or
in 45° steps by reversing the lever or its
mounting.
1. Reversed
α
= 5°
2. Forward α = 45°
15˚
15˚
15˚
1
1
2
2
5° steps
throughout
360°
45° steps
throughout
360°
21
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Selection Guide
Osiswitch® XC Product Overview
Setup (continued) Direction of actuation programming
•XCKJ
Head ZCKE05
•XCKS
Head ZCKD05
•XCKD, XCKP, XCKT and XCMD
Head ZCE05
Specific cams for heads ZCKE09 and ZC2J09
1. 0.5 mm (0.02 in.) min.
2. 2 mm (0.08 in.) min.
A = length of lever + 11 mm (0.43 in.)
ZCKE09: h = 13–18 mm (0.51–0.71 in.) and B = 12 mm (0.47 in.)max.
ZCKJE09: h = 14–24 mm (0.55–0.94 in.) and B = 6 mm (0.24 in.) max.
ZCKG00 Head Programming
The ZCKG00 head is field convertible to CW, CCW or CW/CCW.
The diagram below shows the conversion process.
2
A
h
B
1
1
22
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Selection Guide
Osiswitch® XC Product Overview
Compliance with standards
The majority of Telemecanique® brand products comply to national standards (such as French NF C standards, German DIN standards), European standards (such
as CENELEC), or international standards (such as IEC). These standards rigidly stipulate the characteristic requirements of the designated products (for example
IEC 60947 relating to low voltage switchgear and controlgear).
These products, when correctly used, enable the production of control equipment assemblies, machine control equipment or installations conforming to their own
specific standards (for example IEC 60204 for the electrical equipment of industrial machines).
IEC 60947-5-1
Insulation coordination (and dielectric strength)
•The standard IEC 60664 defines 4 categories of prospective transient overvoltages. It is important for the user
to select control circuit components which are able to withstand these overvoltages. To these ends, the
manufacturer states the rated impulse withstand voltage (U imp) applicable to the product.
Terminal connections
•The cabling capacity, mechanical robustness and durability of the terminals, as well as the ability to resist
loosening, are verified by standardized tests.
•Terminal reference marking conforms to standard EN 50013.
Switching capacity •With maximum electrical load. A single designation (A300 for example) enables indication of the contact block
characteristics related to its utilization category.
Positive opening operation (IEC 60947-5-1 Appendix K)
•For contacts used in safety applications (end of travel, emergency stop device, etc.) the assurance of positive
opening is required (see IEC 60204, EN 60204) after each test, the opening of the contact being verified by
testing with an impulse voltage (2500 V).
Electrical symbols for contacts
• Form Za,
the 2 contacts are
the same polarity.
• Form Zb,
the 2 contacts are electrically separate.
Symbol for positive opening • Simplified version • Complete symbol
CENELEC EN 50047
The European standards organization CENELEC, which has 14 member countries, has defined in this standard the first type of limit switch.
This standard defines 4 variants of devices (forms A, B, C, E).
Limit switches XCKP, XCKD and XCKT conform to standard EN 50047.
Form A, with roller lever Form B, with end plunger (rounded)
1. Minimum value
2. Maximum value
A: reference axis
H: differential travel
P: tripping point
E: cable entry
Form C, with end roller plunger Form E, with roller lever for 1 direction of actuation
30
(2)
12,5
(1)
50 (2)
5
(1)
10
(1)
E
20
(1)
31
55
H
A
55
(2)
40
P
(2)
12,5
21
(1)
H
15
(1)
P
2,5
(1)
10
(1)
25
(1)
31
(1)
H
P
H
35
P
25
20
(1)
28
H
40
30
(2)
P
20
(1)
5
(1)
10
(1)
12,5
10 2
23
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Selection Guide
Osiswitch® XC Product Overview
Compliance with standards (continued)
CENELEC EN 50041
The European standards organization CENELEC, which has 14 member countries, has defined in this standard the second type of limit switch.
It defines 6 variants of devices (forms A, B, C, D, F, G).
Limit switches XCKJ and XCKS conform to standard EN 50041.
Form A, with roller lever Form B, with end plunger (rounded)
1. Minimum value
2. Maximum value
A: reference axis
B: optional elongated holes
H: differential travel
P: tripping point
E: cable entry
Za: tripping zone
Sa: tripping threshold
Form C, with end roller plunger Form D, with rod lever
Form F, with side plunger (rounded) Form G, with side roller plunger
70
(2)
5
(1)
10
(1)
15
(1)
46
(2)
30
E
42,5
(2)
80
(2)
67
70
(2)
A
20
(1)
HP
7,3
5,3
B
31
(1)
40
(1)
H
P
20
(1)
58
H
P
10
(1)
3
(1)
44
(1)
53
(1)
H
P
100
(1)
20
(2)
20
(2)
40˚
40˚
Za
Sa
200
H
20
30
(1)
39
(1)
H
47
(1)
56
(1)
H
55
3
H
20
20
(1)
41
41
(1)
50
(1)
H
3
(1)
20
H
72
20
(1)
30˚
H
58
59
(1)
67
(1)
H
24
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature Snap Switches
XEP and XC0
Introduction Electromechanical detection
Osiswitch miniature snap switches, featuring electromechanical technology, assure the
following functions:
•detection of presence or absence
•detection of position.
Actuation of the operator (plunger or lever) on the miniature snap switch causes the electrical
contact to change state. This information can then be processed by a PLC controlling the
installation.
Osiswitch miniature snap switches can be used both for industrial applications and the
building sector.
Features
Osiswitch miniature snap switches incorporate a C/O snap-action, single-break contact. They
are characterized by:
•high electrical ratings for their very small size
•short tripping travel
•low tripping force
•high repeat accuracy on the
tripping points
•long service life
Terminology Forces
Maximum tripping force: maximum force which must be applied to the operator to move it
from the rest (unactuated) position to the trip position (tripping point).
Minimum release force: value to which the force on the operator must be reduced to allow
the snap action mechanism to return to its rest (unactuated) position.
Maximum permissible end of travel force: maximum force that can be applied to the
operator at the end of its travel without damaging the switch.
Position / Travel
1. Tripping point: position of the operator in relation to the switch mountings (mounting hole
center line) at the instant the switch contact changes state.
A. Differential travel: distance between the tripping point and the position at which the snap
action mechanism returns to its initial state on release of the operator.
2. Overtravel limit: position of the operator when an extreme force has moved it to the
effective end of its available travel.
B. Overtravel: distance between the tripping point and the overtravel limit.
The reference point for the figures given for forces and travel is a point F, which is situated on
the plunger in the case of a basic switch or at 3 mm (0.12 in.) from the end of the plain lever
in the case of a lever operated switch.
Mechanical characteristics Changeover time
T1: bounce time
T: changeover time
This is the time taken by the moving contact when moving from one fixed contact to another
until it becomes fully stable (contact bounce included).
This time is related to the inter-contact distance, the mechanical characteristics of the snap
action mechanism, and the mass of the moving element. However, due to the snap action
mechanisms used, the time is largely independent of the speed of operation. It is normally
less than 20 ms (including bounce times of less than 5 ms).
Operating speed and maximum usable operating rate
Our miniature snap switches are suitable for a wide range of operating speeds: generally,
from 1 mm/mn to 1 m/s (0.04 in/mn to 3.28 ft/s). The maximum usable operating rate on a
light electrical load may be as high as 10 operations/second.
Mounting Mounting and operation
Operating speed and rate
To conform to the leakage paths and air gaps in standards EEC 24 - EN/IEC 61058 and
EN/IEC 60947:
•an insulation pad must be inserted between the snap switch and the mounting surface if
the latter is metal,
•manual operation of a metal actuator must only be carried out with the aid of an
intermediate actuator made of an insulating material.
•The installer must ensure adequate protection against direct contact with the output
terminals.
Actuation method
Direct operation: The plunger should preferably be actuated along its axis. However, the
majority of our miniature snap switches will accept skewed operation provided the angle of
actuation is not more than 45°.
The travel of the actuator must not be limited to only reaching the tripping point. The actuator
must always be operated in such a manner that the plunger reaches a point at least 0.5 times
the stated overtravel value of the switch. Also, it should not reach its end of travel nor exceed
the maximum permissible end-of-travel force.
XEP3
XC0
XEP4E1W
p
XEP5
XEP4E1FD
p
NC
NO
TT1
ABC
ABC
25
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature Snap Switches
XEP and XC0
Mounting (continued) Actuation method (continued)
Lever operators:
•when actuation is by a roller lever, force should preferably be applied in the
direction shown in the diagrams opposite,
•where the movements involved are fast, the ramp should be so designed as to
ensure that the operator is not subjected to any violent impact or abrupt release.
Mounting—Tightening torque
The tightening torque of the fixing screws must conform to the following values:
Ø of mounting screw 22.5 33.5 4
Tightening torque,
N•cm (lb-in)
Maximum 25 (2.21) 35 (3.10) 60 (5.31) 100 (8.85) 150 (13.28)
Minimum 15 (1.33) 25 (2.21) 40 (3.54) 60 (5.31) 100 (8.85)
Resistance to mechanical shock and vibration
•Resistance to shock and vibration depends on the mass of the moving parts and
on the forces holding the contacts together.
•In general, for a miniature snap switch without accessory:
— vibration > 10 gn, 10 to 500 Hz
— shock > 50 gn 11 ms 1/2 sine wave
Electrical characteristics Operating curves
These indicate the electrical life of the miniature snap switches under standard
conditions [20°C (68 °F), 1 cycle/2 seconds], by showing the number of switching
operations which can be performed with given types of load. For sealed snap
switches, the operating rate is 1 cycle/6 s.
Insulation resistance
The insulation resistance of the miniature snap switches is generally greater than
50,000 MΩ, measured at 500 Vdc
Dielectric strength
The dielectric strength of our miniature snap switches is generally superior to:
•1500 V between live parts and earth
•1000 V between contacts
•600 V between contacts for switches with an inter-contact distance less than 0.3 mm
3
0˚ 30˚
ABC ABC
0,1 0,2 0,5
12 5
16 A10
10
7
10
6
10
5
10
4
2
2
2
5
5
5
Resistive circuit
Inductive circuit
Cos
ϕ
0.8
Number of cycles
Current
1500 V
1000 V
26
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature Snap Switches
Subminiature (DIN 41635 B format, sealed) and Sub-subminiature (DIN 41635 D format)
Catalog numbers
Subminiature design, DIN 41635 B format, sealed
Type of operator Plunger Flat lever (1) Roller lever (1)
Single-pole C/O
snap action
Wiring:
1 Black
2 Grey
4 Blue
2.8 mm (0.11 in.) cable
clip tag connections XEP4E1W7 (3) XEP4E1W7A326 (3) XEP4E1W7A454 (3)
Weight, g (oz) 2.4 (0.08) 3.1 (0.11) 3.2 (0.11)
Pre-cabled connections XEP4E1FD (3) XEP4E1FDA326 (3) XEP4E1FDA454 (3)
Weight, g (oz) 14.1 (0.50) 14.8 (0.52) 14.9 (0.53)
Separate components
Flat lever (2) ZEP4L326 (3) ——
Weight, g (oz) 0.7 (0.02) — —
Roller lever (2) ZEP4L454 (3) ——
Weight, g (oz) 0.8 (0.03) — —
Sub-subminiature design, DIN 41635D format
Type of operator Plunger Flat lever (1)
Single-pole C/O
snap action
Solder tag
connections XEP5P1W2 (3) XEP5P1W2Z55B (3)
Weight, g (oz) 1.4 (0.05) 1.9 (0.07)
Dimensions
XEP4E1W7 XEP4E1W7A326 XEP4E1W7A454
XEP4E1FD XEP4E1FDA326 XEP4E1FDA454
XEP5P1W2 XEP5P1W2Z55B
1. To avoid damage to the mounting spigots, removal of the lever from complete products is not recommended.
2. Levers only for mounting on basic (plunger) snap switches (XEP4E1W7 and XEP4E1FD).
3. Switches sold in lots of 5.
4. A, B, Z: lever fixing positions.
142
142
A
(4)
==
7,5
Ø1,2
7,5
5,2
9,5
0,5
2,5
r = 2
7,5
2,5
2,25
B
(4
)
1,55
Ø2,2
8,4
39˚
0,5
2,8
2
2,2
r = 24
F
4x0,3
2,2
r = 20
3
5
4,8
B
(4)
A
(4)
6,4 3
19,9
3
19,9
2
2,2
r = 24
F
2,2
4,8
r = 20
3
19,9
2,1
1,9
1,5
9,62,3
0,8
5
8,4
4,753,8
1,5
0,5
1,4 4,7
4,7
0,5
13
8,9
r = 19,9
F
9,1
10,3
0,4x2,9
Z
(4)
5,1
6,7
4,7
27
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature Snap Switches
Subminiature (DIN 41635 B format, sealed) and Sub-subminiature (DIN 41635 D format)
Switch type
XEP4E1••,
XEP5P1W2
XEP4E1••A326,
XEP5P1W2Z55B XEP4E1••A454
Plunger Flat lever Roller lever
Environmental characteristics
Lever fixing position (1) —AA
Switch actuation On end Horizontal
Product certifications e, IEC 60947-5-1, EN 60947-5-1, c UR us, UL 1054, EN 61058
Degree of protection IP 67 XEP4E1FD••, case IP 67 and tags IP 00 XEP4E1W7••, case IP 40 and tags IP 00 XEP5P1W2••
Operating temperature - 40...+ 105 °C XEP4E1FD••, -40...+125 °C XEP4E1W•••• and XEP5P1•••
Materials
Enclosure Polyester XEP4, diallyl-phtalate XEP5
Lever — Stainless steel Stainless steel, glass reinforced polyamide roller
Contact AgCdO XEP4E1••, Ag XEP5
Tags Tinned brass XEP4E1W•••, gold plated brass XEP5P1••
Mechanical characteristics
Lever
fixing
position
(1)
Maximum tripping force,
N (oz)
XEP4 A2.5 N (8.99 oz) 0.63 N (2.27 oz) 0.83 N (2.99 oz)
B2.5 N (8.99 oz) 1.25 N (4.50 oz) 1.67 N (6.01 oz)
XEP5 2 N (7.19 oz) 0.80 N (2.88 oz) —
Minimum release force,
N (oz)
XEP4 A0.80 N (2.88 oz) 0.20 N (0.72 oz) 0.27 N (0.97 oz)
B0.80 N (2.88 oz) 0.40 N (1.44 oz) 0.53 N (1.91 oz)
XEP5 0.40 N (1.44 oz) 0.15 N (0.54 oz) —
Maximum permissible
end of travel force, N (lb)
XEP4 A10 N (2.25 lb) 2.5 N (0.56 lb) 3.33 N (0.75 lb)
B10 N (2.25 lb) 5 N (1.12 lb) 6.67 N (1.50 lb)
XEP5 10 N (2.25 lb) — —
Tripping point (TP) (2) XEP4 A8.40 +/- 0.3 mm 10.7 +/- 1.7 mm 15.5 +/- 1.4 mm
B8.40 +/- 0.3 mm 9.6 +/- 1.0 mm 14.5 +/- 0.9 mm
XEP5 8.40 mm 9.20 mm —
Maximum differential travel XEP4 A0.13 mm 0.52 mm 0.39 mm
B0.13 mm 0.26 mm 0.20 mm
XEP5 0.06 mm 0.25 mm —
Minimum overtravel XEP4 A0.60 mm 2.40 mm 1.80 mm
B0.60 mm 1.20 mm 0.90 mm
XEP5 0.10 mm — —
Inter-contact distance XEP4 0.4 mm
XEP5 0.3 mm
Mechanical durability XEP4 2 million operating cycles
XEP5 0.1 million operating cycles
Electrical characteristics
Operational characteristics XEP4
AC-15: B300 (Ue: 240 V, Ie: 1.5 A)
DC-13: R300 (Ue: 250 V, Ie: 0.1 A) conforming to IEC 60947-5-1, EN 60947-5-1 Appendix A
125-250 Vac 6.0 A conforming to UL 1054
6 (1) A 250 Vac 10,000 cycles conforming to EN 61058
XEP5 AC-15: D300 (Ue: 240 V, Ie: 0.3 A) conforming to IEC 60947-5-1, EN 60947-5-1 Appendix A
Thermal current XEP4 7.5 A on 250 V (50/60 Hz)
XEP5 8.5 A on 250 V (50/60 Hz)
Connection XEP4 XEP4E1W7•: 2.8 mm (0.11 in.) cable clip tags
XEP4E1FD: Pre-cabled (horizontally in-line), 3 x 0.5 mm2, length 0.5 m (1.6 ft)
XEP5 Solder tags
Operating curves
XEP4E1•• XEP5P1••
1. Miniature snap switches fitted with a lever are supplied with the lever fixed in position A (see page 26).
For basic (plunger) snap switches, it is possible to fix a lever in position A or B, depending on the required tripping conditions (see page 26).
2. Position of the operator in relation to the switch mountings (mounting hole center line), at the instant the contact changes state.
0,05 0,1 0,2 0,5
12 510A
2x10
10
10
10
6
5
4
6
Number of cycles
Current
250 V
a
:
resistive circuit
10
3
10
4
2
2
10
5
2
0,1 0,2 0,5 1 2 5 10 16 A
5
5
1
2
Current
1 Resistive circuit
2 Inductive circuit
Cos
ϕ
0.8
Number of cycles
250 V
a
28
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature Snap Switches
Miniature (DIN 41635 A format)
Catalog numbers
Type of operator Plunger (2) Flat lever (1) (2) Roller lever (1) (2)
Single-pole
C/O
snap action
Standard
contacts
Solder tags XEP3S1W2 XEP3S1W2B524 XEP3S1W2B529
4.8 mm (0.19 in.) cable clip tags XEP3S1W6 XEP3S1W6B524 XEP3S1W6B529
6.35 mm (0.25 in.) cable clip tags XEP3S1W3 XEP3S1W3B524 XEP3S1W3B529
Weight, g (oz) 5.6 (0.20) 6.3 (0.22) 6.6 (0.23)
Very low
operating
force
contacts
Solder tags XEP3S2W2 XEP3S2W2B524 XEP3S2W2B529
4.8 mm (0.19 in.) cable clip tags XEP3S2W6 XEP3S2W6B524 XEP3S2W6B529
6.35 mm (0.25 in.) cable clip tags XEP3S2W3 XEP3S2W3B524 XEP3S2W3B529
Weight, g (oz) 5.6 (0.20) 6.3 (0.22) 6.6 (0.23)
Separate components
Flat lever (3) ZEP3L524
Weight, g (oz) 0.7 (0.02)
Roller lever (3) ZEP3L529
Weight, g (oz) 1 (0.04)
Dimensions
XEP3S•W2 XEP3S•W6 XEP3S•W3
ZEP3L529 ZEP3L524
1. To avoid damage to the mounting spigots, removal of the lever from complete products is not recommended.
2. Switches sold in lots of 10.
3. Levers only for mounting on basic (plunger) snap switches (XEP3S•W2, XEP3S•W3 and XEP3S•W6), in mounting positions A, B or C.
1
4
2
=
2,8 22,2 2,8
20,2
15,8
3,4
3
10,3
=
6,3
3,2
3,2
3,2
3
ABC
47˚
1,7
2,8
3,9x0,8
10,3
3,9
27,8
3
1,4
=
2,8 22,2 2,8
20,2
15,8
4,8x0,5
3,4
3
10,3
=
6,3 3,2
10,7
3
4
ABC
10,3
3,9
27,8
33,1
7,1
17,4
47˚
=
2,8 22,2 2,8
20,2
15,8
3,4 9,8
3
10,3
=
3
ABC
10,3
3,9
27,8
4,3
9,3
6,3x0,8
47˚
1,7
3
17,4
6,2
6,7
3
4,3
3,4
2,4
r=24,1
4,8
6,3
87
4,3
2,4
r=25,4
0,3
29
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature Snap Switches
Miniature (DIN 41635 A format)
Switch type
Type of operator
XEP3 S•W2 XEP3 S•W2B254 XEP3 S•W2B259
Plunger Flat lever Roller lever
Environmental characteristics
Lever fixing position (1) —BB
Switch actuation On end Horizontal
Product certifications cUR us, e, IEC/EN 60947-5-1, UL 1054, EN 61058-1
Degree of protection Case IP 40 and tags IP 00
Operating temperature - 25...+ 125 °C
Materials
Enclosure Polyester
Lever — Stainless steel Stainless steel, glass reinforced polyamide roller
Contact AgNi
Mechanical characteristics
Lever fixing position (1)
Maximum tripping force,
N (oz)
Standard
A 0.80 N (2.88 oz) 0.20 N (0.72 oz)
B 0.80 N (2.88 oz) 0.40 N (1.44 oz)
C 0.80 N (2.88 oz) 0.53 N (1.91 oz)
Very low force
A 0.25 N (0.90 oz) 0.06 N (0.22 oz)
B 0.25 N (0.90 oz) 0.13 N (0.47 oz)
C 0.25 N (0.90 oz) 0.17 N (0.61 oz)
Minimum release force,
N (oz)
Standard
A 0.20 N (0.72 oz) 0.05 N (0.18 oz)
B 0.20 N (0.72 oz) 0.10 N (0.36 oz)
C 0.20 N (0.72 oz) 0.13 N (0.47 oz)
Very low force
A 0.05 N (0.18 oz) 0.01 N (0.04 oz)
B 0.05 N (0.18 oz) 0.03 N (0.11 oz)
C 0.05 N (0.18 oz) 0.03 N (0.11 oz)
Maximum permissible
end of travel force, N (lb)
Standard,
very low force
A 20 N (4.50 lb) 5 N (1.12 lb)
B 20 N (4.50 lb) 10 N (2.25 lb)
C 20 N (4.50 lb) 13 N (2.92 lb)
Tripping point (TP) (2) Standard,
very low force
A 14.70+/- 0.4 mm 15.20+/- 2.5 mm 20.5+/- 2.9 mm
B14.70
+/- 0.4 mm 15.20+/- 1.0 mm 20.5+/- 1.5 mm
C14.70
+/- 0.4 mm 15.20+/- 0.8 mm 20.5+/- 1.2 mm
Maximum differential travel Standard,
very low force
A 0.35 mm 1.40 mm
B 0.35 mm 0.70 mm
C 0.35 mm 0.53 mm
Minimum overtravel
Standard
A 1.20 mm 4.80 mm
B 1.20 mm 2.40 mm
C 1.20 mm 1.80 mm
Very low force
A 1.10 mm 4.40 mm
B 1.10 mm 2.20 mm
C 1.10 mm 1.65 mm
Inter-contact distance 0.40 mm
Mechanical durability
for 2/3 overtravel
Standard 20 million operating cycles
Very low force 50 million operating cycles
Electrical characteristics
Operational characteristics
Standard
AC-15: B300 (Ue: 240 V, Ie: 1.5 A)
DC-13: R300 (Ue: 250 V, Ie: 0.1 A) conforming to IEC/EN 60947-5-1 Appendix A
125-250 Vac 10.1 A—1/2 HP conforming to UL 1054
12 (3) A 250 Vac 10,000 cycles conforming to EN 61058-1
Very low force
AC-15: D300 (Ue: 240 V, Ie: 0.3 A) conforming to IEC/EN 60947-5-1 Appendix A
125-250 Vac 4 A—1/10 HP conforming to UL 1054
4 (1) A 250 Vac 50,000 cycles conforming to EN 61058-1
Thermal current Standard 15 A on 250 V (50/60 Hz)
Very low force 5 A on 250 V (50/60 Hz)
Connection XEP3 S•W2: solder tags, XEP3 S•W6: 4.8 mm (0.19 in.) cable clip tags
XEP3 S•W3: 6.35 mm (0.25 in.) cable clip tags.
Operating curves
XEP3S1•• XEP3S2••
1. Miniature snap switches fitted with a lever are supplied with the lever fixed in position B (see page 28). For basic (plunger) snap switches, it is possible to fix a lever in position A, B or C,
depending on the required tripping conditions (see page 28).
2. Position of the operator in relation to the switch mountings (mounting hole center line), at the instant the contact changes state.
0,1 0,2 0,5 1
2512A
10
7
10
6
10
5
10
4
2
2
2
5
5
5
250 V
Resistive circuit
Inductive circuit
Cos
ϕ
0.8
N
um
b
er o
f
cyc
l
es
Current
0,1 0,2 0,5 1 2 4 A
10
8
10
7
10
6
10
5
2
2
2
5
5
5
250 V
Number of cycles
Resistive circuit
Inductive circuit
Cos
ϕ
0.8
Current
30
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature Snap Switches
Sealed Design Pre-Cabled
Type of head Plunger (mounting by the body)
Type of operator Head with flat plunger Head with domed encased plunger
Catalog numbers
Single-pole C/O snap action
Wiring:
1 Black
2 Brown
4 Blue
XC010L2 XC011L2
Weight, kg (lb) 0.145 (0.320) 0.150 (0.331)
Dimensions
XC010L2
XC011L2
1
2
4
1
10,3
12,3
6
20
32
26
16
49
71
24
2000
12
PA
1
10,3
18,3
6
20
32
26
16
49
71
24
2000
PA
r6
31
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature Snap Switches
Sealed Design Pre-Cabled
Switch type XC010• XC011•
Environmental characteristics
Switch actuation On end, flat plunger (1) On end, domed plunger (1)
Product certifications e, IEC 60947-5-1
Degree of protection IP 66
Operating temperature 0...85 °C (32…185 °F)
Materials
Internal housing Metal
Casing Nitrile
Mounting support Steel, zinc passivated
Contact Ag
Mechanical characteristics
Maximum tripping force 5.3 N (1.19 lb)
Minimum release force 1.5 N (0.34 lb)
Maximum permissible end of travel force 30 N (6.74 lb)
Tripping point (TP) (2) 11.4± 0.4 mm 17.4± 0.5 mm
Maximum differential travel 0.2 mm
Minimum overtravel 0.2 mm
Inter-contact distance 0.5 mm
Mechanical durability 2 million operating cycles
Electrical characteristics
Operational current 1 A on 24 V (50/60 Hz)
Thermal current/insulation voltage 12 A/60 V
Connection A05 VVF cable, 3 x 0.75 mm2, length 2 m (6.6 ft), overall diameter ≤ 7.6 mm (0.30 in.)
Electrical durability AC-15: 0.5 million operating cycles
Operating curve
1. Manual actuation must be made by an intermediate insulated part, in order to meet basic safety requirements.
One of the two mounting holes must also be used as an earth protection terminal.
2. Distance between the base of the switch and the top of the plunger at the instant the contact changes state (see dimensions, page 30).
32
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD
b XCM D
pre-cabled v With head for linear movement (plunger). Mounting by the body.
Page 34
v With head for linear movement (plunger). Mounting by the head.
Page 34
v With head for rotary movement (lever) or multi-directional. Mounting by the body.
Page 35
b XCM D
with integral connector
v With head for linear movement (plunger)
Mounting by the body Mounting by the head
Page 38
v
With head for rotary movement (lever) or multi-directional. Mounting by the body.
Page 39
520341
561279
520343
520344
561280
520346
520347
561281
561282
561283
561284
561285
33
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD
Environmental characteristics
Conforming to standards Products IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C22-2 n° 14
Machine assemblies IEC 60204-1, EN 60204-1
Product certifications UL, CSA (except products with special cables), CCC
Protective treatment Standard version: “TC”
Ambient air temperature Operation: -25…+70 °C (-13…+158 °F). Storage: -40…+70 °C (-40…+158 °F)
Vibration resistance XCMD snap action: 5 gn. XCMD slow break: 25 gn (10…500 Hz)
conforming to IEC 60068-2-6
Shock resistance 25 gn (18 ms) conforming to IEC 60068-2-27
Electric shock protection Class I conforming to IEC 61-140 and NF C 20-030
Degree of protection
NEMA Types 1, 2, 4, 12, 13
IP 66, IP 67 and IP 68 (1) conforming to IEC 60529
IK 06 conforming to EN 50102
Materials Bodies and heads: Zamak® zinc alloy
Repeat accuracy 0.05 mm on the tripping points, with 1 million operating cycles for head with end plunger
Protection against prolonged immersion: the test conditions are subject to agreement between the manufacturer and the user.
Contact block characteristics
Rated operational
characteristics
Switches with 2 contacts
a AC-15; B300 (Ue = 240 V, Ie = 1.5 A)
c DC-13; R300 (Ue = 250 V, Ie = 0.1 A), conforming to IEC 60947-5-1 Appendix A,
EN 60947-5-1
Switches with 3 and 4 contacts
a AC-15; C300 (Ue = 240 V, Ie = 0.75 A)
c DC-13; R300 (Ue = 250 V, Ie = 0.1 A), conforming to IEC 60947-5-1 Appendix A,
EN 60947-5-1
Pre-cabled switches Ithe = 6 A for 2 contacts, 4 A for 3 contacts, 3 A for 4 contacts
Switches with 4-pin
M12 connector Ui = 250 V, Ie = 3 A maximum, Ithe = 3 A
Switches with 5-pin
M12 connector Ui = 60 V, Ie = 4 A maximum, Ithe = 4 A
Switches with 5-pin
7/8" 16UN connector Ui = 250 V, Ie = 6 A maximum, Ithe = 6 A
Rated insulation voltage Ui = 400 V degree of pollution 3 conforming to IEC 60947-5-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Rated impulse withstand voltage U imp = 4 kV conforming to IEC 60947-1, IEC 60664
Positive operation (depending on model) N/C contacts with positive opening operation conforming to IEC 60947-5-1 Appendix K, EN 60947-5-1
Resistance across terminals ≤ 25 mΩ conforming to IEC 60255-7 category 3
Electric shock protection 6 A cartridge fuse type gG (gl)
Minimum actuation speed Snap action contact: 0.01 m/minute (0.03 ft/minute)
Slow break contact: 6 m/minute (19.68 ft/minute)
Electrical durability
•Conforming to IEC 60947-5-1 Appendix C
•Utilization categories AC-15 and DC-13
•Maximum operating rate: 3600 operating cycles/hour
•Load factor: 0.5
a.c. supply
a 50/60 Hz
o inductive circuit
XCMD snap action (N/C + N/O, N/C + N/C,
N/C + N/C + N/O, N/C + N/C + N/O + N/O
contacts)
XCMD slow break (N/C + N/O, N/C + N/C +
N/O contacts)
d.c. supply c
Power switched in W for
5 million operating cycles
Power switched in W for
5 million operating cycles
Voltage V 24 48 120 Voltage V 24 48 120
oW321 oW433
0,1
0,5
1
5
0,5 1 5 10
2
3
4
230 V
234
Ithe
6
48 V
12/24 V
110 V
Millions of operating cycles
Current in A
0,5
1
5
0,5 12 610
0,1
Ithe
12/24/48 V
2
3
4
5
34
230 V 110 V
Millions of operating cycles
Current in A
34
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD, Pre-Cabled
Type of head Plunger (mounting by the body) Plunger (mounting by the head)
Type of operator Metal end plunger Metal end plunger
with elastomer boot Steel roller plunger Retractable steel
roller lever plunger
M12 with metal end
plunger
M16 with metal end
plunger with
elastomer boot
M12 with steel roller
plunger
Catalog numbers
2-pole N/C + N/O snap action XCMD2110L1 XCMD2111L1 XCMD2102L1 XCMD2124L1 XCMD21F0L1 XCMD21G1L1 XCMD21F2L1
2-pole N/C + N/O break
before make, slow break
XCMD2510L1 XCMD2511L1 XCMD2502L1 XCMD2524L1 XCMD25F0L1 XCMD25G1L1 XCMD25F2L1
2-pole N/C + N/C snap action ZCMD29L1 +
ZCE10
ZCMD29L1 +
ZCE11
ZCMD29L1 +
ZCE02
ZCMD29L1 +
ZCE24
ZCMD29L1 +
ZCEF0
ZCMD29L1 +
ZCEG1
ZCMD29L1 +
ZCEF2
3-pole N/C + N/C + N/O
snap action
ZCMD39L1 +
ZCE10
ZCMD39L1 +
ZCE11
ZCMD39L1 +
ZCE02
ZCMD39L1 +
ZCE24
ZCMD39L1 +
ZCEF0
ZCMD39L1 +
ZCEG1
ZCMD39L1 +
ZCEF2
3-pole N/C + N/C + N/O break
before make, slow break
ZCMD37L1 +
ZCE10
ZCMD37L1 +
ZCE11
ZCMD37L1 +
ZCE02
ZCMD37L1 +
ZCE24
ZCMD37L1 +
ZCEF0
ZCMD37L1 +
ZCEG1
ZCMD37L1 +
ZCEF2
Weight, kg (lb) 0.180 (0.397) 0.180 (0.397) 0.185 (0.408) 0.200 (0.441) 0.195 (0.430) 0.220 (0.485) 0.205 (0.452)
4-pole N/C + N/C + N/O + N/O
snap action
ZCMD41L1 +
ZCE10
ZCMD41L1 +
ZCE11
ZCMD41L1 +
ZCE02
ZCMD41L1 +
ZCE24
ZCMD41L1 +
ZCEF0
ZCMD41L1 +
ZCEG1
ZCMD41L1 +
ZCEF2
Weight, kg (lb) 0.160 (0.353) 0.160 (0.353) 0.165 (0.364) 0.180 (0.397) 0.175 (0.386) 0.200 (0.441) 0.185 (0.408)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when properly
mounted and using a conforming operator
Characteristics
Switch actuation On end By 30° cam On end By 30° cam
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 0.1 m/s (0.33 ft/s)
Minimum
force or
torque
For tripping 8.5 N (1.91 lb) 7 N (1.57 lb) 2.5 N (0.56 lb) 8.5 N (1.91 lb) 7 N (1.57 lb)
For positive
opening 42.5 N (9.55 lb) 35 N (7.87 lb) 12.5 N (2.81 lb) 42.5 N (9.55 lb) 35 N (7.87 lb)
Cabling PvR cable, 1 m (3.3 ft) long: 5 x 0.75 mm2 for 2-pole contact versions; 7 x 0.5 mm2 for 3-pole contact versions; 9 x 0.34 mm2 for 4-pole contact versions. For
other cable lengths, see page 44.
NOTE: For more information, consult pages 40–42.
BK-WH BK
BU
BN
GN-YE 1,8
05mm
0,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
4,2(P) 1,8
05mm
0,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
4,2(P) 3,1(A)
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU 0mm
1,4
7(P) 11,2(A)
0mm
4,9
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
25(P) 1,8
05mm
0,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
4,2(P) 1,8
05mm
0,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
4,2(P) 3,1(A)
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU 0mm
1,4
7(P)
BK-WH BK
BU
BN
GN-YE
1,8
05 mm
2,6
BK-BK-WH
BN-BU
3,1(P) 1,8
05 mm
2,6
BK-BK-WH
BN-BU
3,1(P) 3,1(A)
0mm
4,6
BK-BKWH
BN-BU
5,6(P) 11,2(A)
0mm
16
BK-BK-WH
BN-BU
19,5(P) 1,8
05 mm
2,6
BK-BK-WH
BN-BU
3,1(P) 1,8
05 mm
2,6
BK-BK-WH
BN-BU
3,1(P) 3,1(A)
0mm
4,6
BK-BKWH
BN-BU
5,6(P)
BK-WH BK
RD
RD-WH
GN-YE
1,8
05 mm
0,8
BK-BK-WH
RD-RD-WH
BK-BK-WH
RD-RD-WH
4,2 (P) 1,8
05 mm
0,8
BK-BK-WH
RD-RD-WH
BK-BK-WH
RD-RD-WH
4,2 (P)
3,1(A)
BK-BK-WH
RD-RD-WH
BK-BK-WH
RD-RD-WH
0mm
1,4
7(P)
11,2(A) 25(P)
0mm
4,9
BK-BK-WH
BK-BK-WH
RD-RD-WH
RD-RD-WH
1,8
05 mm
0,8
BK-BK-WH
RD-RD-WH
BK-BK-WH
RD-RD-WH
4,2 (P) 1,8
05 mm
0,8
BK-BK-WH
RD-RD-WH
BK-BK-WH
RD-RD-WH
4,2 (P)
3,1(A)
BK-BK-WH
RD-RD-WH
BK-BK-WH
RD-RD-WH
0mm
1,4
7(P)
RD-WH RD
BU
BN
GN-YE
BK-WH BK
1,8
5 mm
0
0,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
4,2(P) 1,8
5 mm
0
0,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
4,2(P)
3,1(A)
0mm
1,4
BN-BU
BK-BK-WH
BN-BU
BK-BK-WH
RD-RD-WH
RD-RD-WH
7(P)
11,2(A) 25(P)
0mm
4,9
BU-BN
BK-BK-WH
BU-BN
BK-BK-WH
RD-RD-WH
RD-RD-WH
1,8
5 mm
0
0,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
4,2(P) 1,8
5 mm
0
0,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
4,2(P)
3,1(A)
0mm
1,4
BN-BU
BK-BK-WH
BN-BU
BK-BK-WH
RD-RD-WH
RD-RD-WH
7(P)
RD-WH RD
BU
BN
GN-YE
BK-WH BK
1,8
05 mm
2,6
BK-BK-WH
BN-BU
RD-RD-WH
3,1(P) 1,8
05 mm
2,6
BK-BK-WH
BN-BU
RD-RD-WH
3,1(P)
3,1(A)
0mm
4,6
BK-BK-WH
BN-BU
RD-RD-WH
5,6(P)
11,2(A)
0mm
16
BK-BK-WH
BU-BN
RD-RD-WH
19,5(P)
1,8
05 mm
2,6
BK-BK-WH
BN-BU
RD-RD-WH
3,1(P) 1,8
05 mm
2,6
BK-BK-WH
BN-BU
RD-RD-WH
3,1(P)
3,1(A)
0mm
4,6
BK-BK-WH
BN-BU
RD-RD-WH
5,6(P)
RD-WH RD
VT
VT-WH
GN-YE
BK-WH BK
BU
BN
1,8
5 mm
0
0,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
VT-VT-WH
VT-VT-WH
4,2(P) 1,8
5 mm
0
0,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
VT-VT-WH
VT-VT-WH
4,2(P)
3,1(A)
0mm
1,4
BN-BU
BK-BK
BN-BU
BK-BK-WH
RD-RD-WH
RD-RD-WH
VT-VT-WH
VT-VT-WH
7(P)
11,2(A) 25(P)
0mm
4,9
BU-BN
BK-BK-WH
BU-BN
BK-BK-WH
RD-RD-WH
RD-RD-WH
VT-VT-WH
VT-VT-WH
1,8
5 mm
0
0,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
VT-VT-WH
VT-VT-WH
4,2(P) 1,8
5 mm
0
0,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
VT-VT-WH
VT-VT-WH
4,2(P)
3,1(A)
0mm
1,4
BN-BU
BK-BK
BN-BU
BK-BK-WH
RD-RD-WH
RD-RD-WH
VT-VT-WH
VT-VT-WH
7(P)
35
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD, Pre-Cabled
Type of head Rotary (mounting by the body) Multi-directional
Type of operator Thermoplastic roller
lever Steel roller lever
Roller lever with
ball bearing
mounted roller
Variable length
thermoplastic roller
lever
Cat’s whisker (1)
Catalog numbers
2-pole N/C + N/O snap action XCMD2115L1 XCMD2116L1 XCMD2117L1 XCMD2145L1 XCMD2106L1
2-pole N/C + N/O break before make, slow break XCMD2515L1 XCMD2516L1 XCMD2517L1 XCMD2545L1 XCMD2506L1
2-pole N/C + N/C snap action ZCMD29L1 +
ZCE01 +
ZCY15
ZCMD29L1 +
ZCE01 +
ZCY16
ZCMD29L1 +
ZCE01 +
ZCY17
ZCMD29L1 +
ZCE01 +
ZCY45
ZCMD29L1 +
ZCE06
3-pole N/C + N/C + N/O snap action ZCMD39L1 +
ZCE01 +
ZCY15
ZCMD39L1 +
ZCE01 +
ZCY16
ZCMD39L1 +
ZCE01 +
ZCY17
ZCMD39L1 +
ZCE01 +
ZCY45
ZCMD39L1 +
ZCE06
3-pole N/C + N/C + N/O break before make, slow break ZCMD37L1 +
ZCE01 +
ZCY15
ZCMD37L1 +
ZCE01 +
ZCY16
ZCMD37L1 +
ZCE01 +
ZCY17
ZCMD37L1 +
ZCE01 +
ZCY45
ZCMD37L1 +
ZCE06
Weight, kg (lb) 0.220 (0.485) 0.225 (0.496) 0.220 (0.485) 0.230 (0.507) 0.180 (0.397)
4-pole N/C + N/C + N/O + N/O snap action ZCMD41L1 +
ZCE01 +
ZCY15
ZCMD41L1 +
ZCE01 +
ZCY16
ZCMD41L1 +
ZCE01 +
ZCY17
ZCMD41L1 +
ZCE01 +
ZCY45
ZCMD41L1 +
ZCE06
Weight, kg (lb) 0.200 (0.441) 0.205 (0.452) 0.200 (0.441) 0.210 (0.463) 0.160 (0.353)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening
operation, when properly mounted and
using a conforming operator
1. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mountings.
Characteristics
Switch actuation By 30° cam By any moving part
Type of actuation
Maximum actuation speed 1.5 m/s (4.92 ft/s) 1 m/s (3.28 ft/s)
Minimum force or torque For tripping 0.1 N•m (0.89 lb-in)
For positive opening 0.5 N•m (4.43 lb-in) —
Cabling PvR cable, 1 m (3.3 ft) long: 5 x 0.75 mm2 for 2-pole contact versions; 7 x 0.5 mm2 for 3-pole contact versions,
9 x 0.34 mm2 for 4-pole contact versions. For other cable lengths, see page 44.
NOTE: For more information, consult pages 40–42.
BK-WH BK
BU
BN
GN-YE
25˚
090˚
12˚
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
70˚(P)
20˚
10˚
BK-BK-WH
BU-BN
BK-BK-WH
BU-BN
BK-WH BK
BU
BN
GN-YE
0
BK-BK-WH
BN-BU
25˚ 45˚(P)
36˚ 90˚ 0
BK-BK-WH
BN-BU
25˚ 45˚(P)
36˚ 90˚ 0
BK-BK-WH
BN-BU
25˚ 45˚(P)
36˚ 90˚ 0
BK-BK-WH
BN-BU
25˚ 45˚(P)
36˚ 90˚
20˚
40˚
BK-BK-WH
BN-BU
BK-WH BK
RD
RD-WH
GN-YE
25˚
090˚
12˚
BK-BK-WH
BK-BK-WH
RD-RD-WH
RD-RD-WH
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BK-BK-WH
RD-RD-WH
RD-RD-WH
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BK-BK-WH
RD-RD-WH
RD-RD-WH
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BK-BK-WH
RD-RD-WH
RD-RD-WH
70˚(P)
20˚
10˚
BK-BK-WH
BK-BK-WH
RD-RD-WH
RD-RD-WH
RD-WH RD
BU
BN
GN-YE
BK-WH BK
25˚
090˚
12˚
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
70˚(P)
20˚
10˚
BK-BK-WH
BU-BN
RD-RD-WH
BU-BN
RD-RD-WH
BK-BK-WH
RD-WH RD
BU
BN
GN-YE
BK-WH BK
25˚ 45˚(P)
0 36˚ 90˚
BN-BU
BK-BK-WH
RD-RD-WH
25˚ 45˚(P)
0 36˚ 90˚
BN-BU
BK-BK-WH
RD-RD-WH
25˚ 45˚(P)
0 36˚ 90˚
BN-BU
BK-BK-WH
RD-RD-WH
25˚ 45˚(P)
0 36˚ 90˚
BN-BU
BK-BK-WH
RD-RD-WH
20˚
40˚
BK-BK-WH
BN-BU
RD-RD-WH
RD-WH RD
VT
VT-WH
GN-YE
BK-WH BK
BU
BN
25˚
090˚
12˚
BK-BK-WH
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
BN-BU
VT-VT-WH
RD-RD-WH
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
BN-BU
VT-VT-WH
RD-RD-WH
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
BN-BU
VT-VT-WH
RD-RD-WH
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BK-BK-WH
BN-BU
RD-RD-WH
RD-RD-WH
BN-BU
VT-VT-WH
RD-RD-WH
70˚(P)
20˚
10˚
BK-BK-WH
BU-BN
RD-RD-WH
VT-VT-WH
RD-RD-WH
BK-BK-WH
VT-VT-WH
BU-BN
36
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD, Pre-Cabled—Dimensions
XCMD2•10L1 XCMD2•11L1 XCMD2•02L1
XCMD2•24L1 XCMD2•F0L1 XCMD2•G1L1
XCMD2•F2L1
1. 2 mounting holes Ø 4.2 mm (0.17 in.), counterbored Ø 8 mm (0.31 in.) by 4 mm (0.16 in.) deep.
2. Overall diameter of cable 7.5 mm (0.30 in.).
3. Mounting nut thickness 3.5 mm (0.14 in.).
e: 8 mm (0.31 in.) max, panel cut-out Ø 12.5 mm (0.49 in.).
f: 8 mm (0.31 in.) max, panel cut-out Ø 16.5 mm (0.65 in.).
(1)
(2)
(1)
(2)
(1)
(2)
12
2
45
19
85
(1)
(2)
e
76
52 24
(2)
(3)
f
(2
)
50
88
(3)
36
52
88
e
(2)
37
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD, Pre-Cabled—Dimensions
XCMD2•15L1 XCMD2•16L1 XCMD2•17L1
XCMD2•45L1 XCMD2•06L1
1. 2 mounting holes Ø 4.2 mm (0.17 in.), counterbored Ø 8 mm (0.31 in.) by 4 mm (0.16 in.) deep.
2. Overall diameter of cable 7.5 mm (0.30 in.).
e: 8 mm (0.31 in.) max, panel cut-out Ø 12.5 mm (0.49 in.).
f: 8 mm (0.31 in.) max, panel cut-out Ø 16.5 mm (0.65 in.).
31
(2)
(1)
31
(2)
(1)
31
(2)
(1)
5,5
33
20
30
16
15°
15°
33,5…83,540
53…103
93…143
Ø16
(2)
(1)
(2
)
(1)
40
38
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD, Integral or Remote Connector
Type of head Plunger (mounting by the body) Plunger (mounting by the head)
Type of operator Metal end plunger Metal end plunger
with elastomer boot Steel roller plunger Retractable steel
roller lever plunger
M12 with metal end
plunger
M16 with metal end
plunger with
elastomer boot
M12 with steel roller
plunger
Catalog numbers
Single-pole
C/O
snap action
+ integral M12
4-pin
connector
XCMD2110M12 XCMD2111M12 XCMD2102M12 XCMD2124M12 XCMD21F0M12 XCMD21G1M12 XCMD21F2M12
2-pole
N/C + N/O
snap action
+ integral M12
5-pin
connector
XCMD2110C12 XCMD2111C12 XCMD2102C12 XCMD2124C12 XCMD21F0C12 XCMD21G1C12 XCMD21F2C12
2-pole
N/C + N/C
snap action
+ integral M12
5-pin
connector
ZCMD29C12 +
ZCE10
ZCMD29C12 +
ZCE11
ZCMD29C12 +
ZCE02
ZCMD29C12 +
ZCE24
ZCMD29C12 +
ZCEF0
ZCMD29C12 +
ZCEG1
ZCMD29C12 +
ZCEF2
Weight, kg (lb) 0.085 (0.187) 0.085 (0.187) 0.090 (0.198) 0.105 (0.231) 0.100 (0.220) 0.125 (0.276) 0.110 (0.243)
2-pole
N/C + N/O
snap action
+ M12 5-pin
connector on
0.8 m (2.6 ft)
flying lead
ZCMD21L08R12
+ ZCE10
ZCMD21L08R12
+ ZCE11
ZCMD21L08R12
+ ZCE02
ZCMD21L08R12
+ ZCE24
ZCMD21L08R12
+ ZCEF0
ZCMD21L08R12
+ ZCEG1
ZCMD21L08R12
+ ZCEF2
2-pole
N/C + N/O
snap action
+ 7/8" 16UN
5-pin
connector on
0.8 m (2.6 ft)
flying lead
ZCMD21L08U78
+ ZCE10
ZCMD21L08U78
+ ZCE11
ZCMD21L08U78
+ ZCE02
ZCMD21L08U78
+ ZCE24
ZCMD21L08U78
+ ZCEF0
ZCMD21L08U78
+ ZCEG1
ZCMD21L08U78
+ ZCEF2
Weight, kg (lb) 0.150 (0.331) 0.150 (0.331) 0.155 (0.342) 0.170 (0.375) 0.165 (0.364) 0.190 (0.419) 0.175 (0.386)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when properly
mounted and using a conforming operator
Characteristics
Switch actuation On end By 30° cam On end By 30° cam
Type of actuation
Maximum actuation
speed 0.5 m/s (1.64 ft/s) 0.1 m/s (0.33 ft/s)
Minimum
force or
torque
For tripping 8.5 N (1.91 lb) 7 N (1.57 lb) 2.5 N (0.56 lb) 8.5 N (1.91 lb) 7 N (1.57 lb)
For positive
opening 42.5 N (9.55 lb) 35 N (7.87 lb) 12.5 N (2.81 lb) 42.5 N (9.55 lb) 35 N (7.87 lb)
Positive operation Although their design is identical to the pre-cabled switches, the switches incorporating an M12 4-pin connector cannot be marked with the symbol
because they are single-pole C/O.
NOTE: For more information, consult pages 40–42.
1,8
05mm
0,8
1-2
1-4
1-2
1-4
4,2(P) 1,8
05mm
0,8
1-2
1-4
1-2
1-4
4,2(P)
3,1(A)
1-2
1-4
1-2
1-4
0mm
1,4
7(P)
11,2(A)
0mm
4,9
1-2
1-4
1-2
1-4
25(P)
1,8
05mm
0,8
1-2
1-4
1-2
1-4
4,2(P)
1,8
05mm
0,8
1-2
1-4
1-2
1-4
4,2(P)
3,1(A)
1-2
1-4
1-2
1-4
0mm
1,4
7(P)
1,8
05mm
0,8
1-2
3
-4
1-2
3
-4
4,2(P) 1,8
05mm
0,8
1-2
3
-4
1-2
3
-4
4,2(P) 3,1(A)
1-2
3-4
1-2
3-40mm
1,4
7(P) 11,2(A)
0mm
4,9
1-2
3-4
1-2
3-4
25(P) 1,8
05mm
0,8
1-2
3
-4
1-2
3
-4
4,2(P) 1,8
05mm
0,8
1-2
3
-4
1-2
3
-4
4,2(P) 3,1(A)
1-2
3-4
1-2
3-40mm
1,4
7(P)
4,2(P)
1,8
05m
m
0,8
1 - 2
3 - 4
1 - 2
3 - 4
4,2(P)
1,8
05m
m
0,8
1 - 2
3 - 4
1 - 2
3 - 4
3,1(A)
0mm
1,4
1 - 2
3 - 4
1 - 2
3 - 4
7(P) 11,2(A)
0mm
4,9
1-2
3-4
1-2
3-4
25(P) 4,2(P)
1,8
05mm
0,8
1 - 2
3 - 4
1 - 2
3 - 4
4,2(P)
1,8
05mm
0,8
1 - 2
3 - 4
1 - 2
3 - 4
3,1(A)
0mm
1,4
1 - 2
3 - 4
1 - 2
3 - 4
7(P)
1,8
05mm
0,8
1-2
3
-4
1-2
3
-4
4,2(P) 1,8
05mm
0,8
1-2
3
-4
1-2
3
-4
4,2(P) 3,1(A)
1-2
3-4
1-2
3-40mm
1,4
7(P) 11,2(A)
0mm
4,9
1-2
3-4
1-2
3-4
25(P) 1,8
05mm
0,8
1-2
3
-4
1-2
3
-4
4,2(P) 1,8
05mm
0,8
1-2
3
-4
1-2
3
-4
4,2(P) 3,1(A)
1-2
3-4
1-2
3-40mm
1,4
7(P)
1,8
05mm
0,8
4
-5
1-2
4
-5
1-2
4,2(P) 1,8
05mm
0
,
8
4
-5
1-2
4
-5
1-2
4,2(P) 3,1(A)
4-5
1-2
4-5
1-20mm
1
,
4
7(P) 11,2(A)
0mm
4,9
4-5
1-2
4-5
1-2
25(P) 1,8
05mm
0,8
4
-5
1-2
4
-5
1-2
4,2(P) 1,8
05mm
0
,
8
4
-5
1-2
4
-5
1-2
4,2(P) 3,1(A)
4-5
1-2
4-5
1-20mm
1,4
7(P)
39
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD, Integral or Remote Connector
Type of head Rotary (mounting by the body) Multi-directional
Type of operator Thermoplastic roller
lever Steel roller lever Roller lever with ball
bearing mounted roller
Variable length
thermoplastic roller
lever
Cat’s whisker (1)
Catalog numbers
Single-pole C/O snap action
With integral M12 4-pin connector
XCMD2115M12 XCMD2116M12 XCMD2117M12 XCMD2145M12 XCMD2106M12
2-pole N/C + N/O snap action
With integral M12 5-pin connector
XCMD2115C12 XCMD2116C12 XCM D2117C12 XCMD2145C12 XCMD2106C12
2-pole N/C + N/C snap action
With integral M12 5-pin connector
ZCMD29C12 +
ZCE01 +
ZCY15
ZCMD29C12 +
ZCE01 +
ZCY16
ZCMD29C12 +
ZCE01 +
ZCY17
ZCMD29C12 +
ZCE01 +
ZCY45
ZCMD29C12 +
ZCE06
Weight, kg (lb) 0.125 (0.276) 0.130 (0.287) 0.125 (0.276) 0.135 (0.298) 0.085 (0.187)
2-pole N/C + N/O snap action
With M12 5-pin connector on 0.8 m (2.6 ft)
flying lead
ZCMD21L08R12
+ ZCE01 +
ZCY15
ZCMD21L08R12
+ ZCE01 +
ZCY16
ZCMD21L08R12
+ ZCE01 +
ZCY17
ZCMD21L08R12
+ ZCE01 +
ZCY45
ZCMD21L08R12
+ ZCE06
2-pole N/C + N/O snap action
With 7/8" 16UN 5-pin connector on 0.8 m
(2.6 ft) flying lead
ZCMD21L08U78
+ ZCE01 +
ZCY15
ZCMD21L08U78
+ ZCE01 +
ZCY16
ZCMD21L08U78
+ ZCE01 +
ZCY17
ZCMD21L08U78
+ ZCE01 +
ZCY45
ZCMD21L08U78
+ ZCE06
Weight, kg (lb) 0.200 (0.441) 0.205 (0.452) 0.200 (0.441) 0.210 (0.463) 0.160 (0.353)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening
operation, when properly mounted and using
a conforming operator
1. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mounting.
Characteristics
Switch actuation By 30° cam By any moving part
Type of actuation
Maximum actuation speed 1.5 m/s (4.92 ft/s) 1 m/s (3.28 ft/s)
Minimum force or torque For tripping 0.1 N•m (0.89 lb-in)
For positive opening 0.5 N•m (4.43 lb-in) —
Positive operation
Although their design is identical to the pre-cabled switches, the switches incorporating an M12 4-pin connector cannot
be marked with the symbol because they are single-pole C/O.
25˚
090˚
12˚
1-2
1-4
1-2
1-4
70˚(P) 25˚
090˚
12˚
1-2
1-4
1-2
1-4
70˚(P) 25˚
090˚
12˚
1-2
1-4
1-2
1-4
70˚(P) 25˚
090˚
12˚
1-2
1-4
1-2
1-4
70˚(P) 20
˚
10˚
1-2
1-4
1-2
1-4
25˚
090˚
12˚
1-2
3-4
1-2
3-4
70˚(P) 25˚
090˚
12˚
1-2
3-4
1-2
3-4
70˚(P) 25˚
090˚
12˚
1-2
3-4
1-2
3-4
70˚(P) 25˚
090˚
12˚
1-2
3-4
1-2
3-4
70˚(P) 20˚
10˚
1-2
3-4
1-2
3-4
20˚
090˚
12˚
3-4
1-2
1-2
3
-4
70˚
(P)
20˚
090˚
12˚
3-4
1-2
1-2
3-4
70˚
(P)
20˚
090˚
12˚
3-4
1-2
1-2
3-4
70˚
(P)
20˚
090˚
12˚
3-4
1-2
1-2
3-4
70˚
(P)
20˚
10˚
1-2
3-4
1-2
3-4
25˚
090˚
12˚
1-2
3-4
1-2
3-4
70˚(P) 25˚
090˚
12˚
1-2
3-4
1-2
3-4
70˚(P) 25˚
090˚
12˚
1-2
3-4
1-2
3-4
70˚(P) 25˚
090˚
12˚
1-2
3-4
1-2
3-4
70˚(P) 20˚
10˚
1-2
3-4
1-2
3-4
25˚
090˚
12˚
4-5
1-2
4-5
1-2
70˚(P) 25˚
090˚
12˚
4-5
1-2
4-5
1-2
70˚(P) 25˚
090˚
12˚
4-5
1-2
4-5
1-2
70˚(P) 25˚
090˚
12˚
4-5
1-2
4-5
1-2
70˚(P) 20˚
10˚
4-5
1-2
4-5
1-2
40
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD—Modular
ZCE 02 ZCE 29
ZCE 10 ZCE 11 ZCE 13 ZCE 14
ZCE 07 ZCE 08 ZCE 06
ZCE 67
ZCE 21 ZCE 27 ZCE 28 ZCE 24
ZCE 62
ZCE 63 ZCE 64 ZCE 65 ZCE 66
ZCM D21 ZCM D29 ZCM D25 ZCM D37 ZCM D39
ZCM D21L1
ZCM D21L2
ZCM D21L5
ZCM D29L1
ZCM D29L2
ZCM D29L5
ZCM D25L1
ZCM D25L2
ZCM D25L5
ZCM D37L1
ZCM D37L2
ZCM D37L5
ZCM D39L1
ZCM D39L2
ZCM D39L5
ZCE F0 ZCE F2 ZCE G1
(1) (1) (1) (1) (1)
Thermoplastic roller
lever plunger,
horizontal
actuation
Thermoplastic roller
lever plunger,
vertical actuation
Thermoplastic roller
lever plunger,
horizontal or vertical
actuation
Retractable
steel roller lever
plunger
Side metal
plunger,
adjustable Side metal
plunger
Side steel
roller plunger,
horizontal
Side steel
ball bearing
plunger
M12 with
metal end
plunger
Side steel
roller plunger,
vertical
M12 with
steel
roller
plunger
M16 with
steel end
plunger
with
elastomer
boot
Steel
roller
plunger
Steel
roller plunger
with elastomer
boot
Spring rod
with
thermoplastic
end
Spring rod Cat’s
whisker
Metal end
plunger
Metal end plunger
with elastomer
boot
Steel ball bearing
plunger
Metal end
plunger,
adjustable
Side
Cat’s
whisker
Body with
2-pole
N/C +
N/O snap
action
contact
Body with
2-pole
N/C + N/C
snap
action
contact
Body with
2-pole
N/C + N/O
break before
make, slow
break
contact
Body with
3-pole
N/C + N/C
+ N/O break
before
make, slow
break
contact
Body with
3-pole
N/C + N/C
+ N/O snap
action
contact
Bodies with pre-
cabled contacts
Bodies with pre-
cabled contacts
Bodies with pre-
cabled contacts
Bodies with pre-
cabled contacts
Bodies with pre-
cabled contacts
1. Pre-cabled connection components: replace the “•” in the catalog number with the required cable length in meters, either: 1, 2, 3, 5, 7 or 10.
Example: ZCM C21L• becomes ZCM C21L7 for a 7 m (23.0 ft) cable.
Note: only cable lengths of 1, 2 and 5 m (3.3, 6.6, and 16.4 ft) are available for pre-cabled connection components ZCM C37L• and ZCM C39L•.
41
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD—Modular
ZCE 01
ZCE 09
ZCY 71ZCY 61
ZCY 19 ZCY 12 ZCY 15 ZCY 16ZCY 18
ZCY 17 ZCY 25 ZCY 26 ZCY 23
ZCY 44 ZCY 45 ZCY 46 ZCY 48
ZCY 22 ZCY 81 ZCY 91
ZCY 54 ZCY 55 ZCY 59
ZCY 53
ZCM D41L1
ZCM D41L2
ZCM D41L5
ZCM D21C12
ZCM D29C12
ZCM D21M12
ZCM D21L08U78
ZCM D21L08R12
(1)
Round rod lever,
steel, Ø 3 (0.12)
L = 125 (4.92)
Square rod
lever, steel,
U3 (0.12)
L = 125 (4.92)
Round rod lever,
glass fibre,
Ø 3 (0.12)
L = 125 (4.92)
Round rod lever,
thermoplastic,
Ø 6 (0.24)
L = 200 (7.87)
Ceramic
roller lever
Spring lever with
thermoplastic
end
Spring–rod
lever, metal
Variable length
thermoplastic
roller lever,
with pliable
lever
Variable length
thermoplastic
roller lever
Variable length
steel roller
lever
Variable length
steel roller lever,
with pliable
lever
Spring return
for actuation
from left AND
right Steel ball
bearing mounted
roller lever,
track 20/36
(0.79/1.42)
Thermoplastic
roller lever,
track 24/31
(0.94/1.22)
Steel roller lever,
track 24/31
(0.94/1.22)
Steel ball bearing
mounted roller
lever,
track 24/31
(0.94/1.22)
Thermoplastic
roller lever,
track 20/36
(0.79/1.42)
Steel roller lever,
track 20/36
(0.79/1.42)
Steel ball bearing
mounted roller
lever,
track 16/39
(0.63/1.54)
Thermoplastic
roller lever,
track 16/39
(0.63/1.54)
Steel roller lever,
track 16/39
(0.63/1.54)
Stay put
for actuation
from left AND
right
Forked arm with
rollers, 2 track,
track 21/35
(0.83/1.38)
Forked arm with
rollers, 1 track,
track 28 (1.10)
Pre-cabled bodies
with 4-pole
N/C + N/C + N/O +
N/O snap action
contact
Bodies with integral connector, with
2-pole snap action contact:
N/C + N/O, M12 5-pin connector
N/C + N/C, M12 5-pin connector
C/O, M12 4-pin connector
Body with 7/8" 16UN 5-pin connector
on 0.8 m (2.6 ft) flying lead, with
2-pole N/C + N/O snap action contact
Body with M12 5-pin connector on
0.8 m (2.6 ft) flying lead, with
2-pole N/C + N/O snap action contact
1. Cannot be used on bodies ZCMD21, ZCMD29, ZCMD39, ZCMD41, ZCMD21C12,
ZCMD21M12, ZCMD29C12, ZCMD21L08•••.
Dimensions: mm (in.)
42
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD—Modular
Special Features and Catalog Number Explanation
Interpretation of the Catalog Number
XCM D 21 02 qL1
XCM—Assembled unit Contact Description Cable Length
ZCM—Body, contacts and base 21—1 N.O. + 1 N.C. Snap Action Silver L1—1 m (3.3 ft)
25—1 N.O. + 1 N.C. Slow Make/Break Silver L2—2 m (6.6 ft)
29—1 N.C. + 1 N.C. Snap Action Silver L3—3 m (9.8 ft)
37—1 N.O. + 2 N.C. Slow Make/Break Silver L5—5 m (16.4 ft)
39—1 N.O. + 2 N.C. Snap Action Silver L7—7 m (23.0 ft)
41—2 N.O. + 2 N.C. Snap Action Silver L10—10 m (32.8 ft)
61—1 N.O. + 1 N.C. Snap Action Gold
65—1 N.O. + 1 N.C. Slow Make/Break Gold Head Assembly k
69—1 N.C. + 1 N.C. Snap Action Gold 01—Rotary Head without Lever Arm
77—1 N.O. + 2 N.C. Slow Make/Break Gold 02—Steel Roller Plunger
79—1 N.O. + 2 N.C. Snap Action Gold 05—Rotary Head without lever arm /
Programmable f
81—2 N.O. + 2 N.C. Snap Action Gold 06—Cat Whisker
07—Spring Rod with Plastic End c
Body (or base) 08—Spring Rod c
D—Metal Modular 09—Maint. Rotary without Arm c
N—Plastic (not modular) 10—Top Push Rod Plunger
C—Plug-in Base (with ZCM only) 11—Booted Top Push Rod Pl.
13—Top Ball Bearing Plunger c
14—Adjustable Top Plunger c
21—One-way Horiz. Plastic Roller
24—Retractable Steel Roller,
9 mm (0.35 in.)
27—One-way Vert. Plastic Roller
28—One-way Horiz. or Vert. Roller
29—Booted Top Roller Plunger c
62—Adjust. Side Push Rod Pl. c
Important Note:
Use this chart for interpretation only. Some possibilities are not shown
and some combinations of components are not available. Some switches
are not modular. Refer to the additional information in this catalog.
For interpretation of catalog numbers for heads and levers, see page 40.
63—Side Push Rod Plunger c
64—Horiz. Side Roller Plunger c
65—Vertical Side Roller Plunger c
66—Side Ball Bearing Plunger c
67—Horizontal Cat Whisker c
F0—M12 Threaded Plunger Head c
F2—M12 Threaded Roller Pl. Hd. c
G1—M16 Threaded Booted Pl. Hd. c
H0—M18 Threaded Plunger Head c
H2—M18 Threaded Roller Pl. Hd. c
cConsult your local field sales office for availability.
qLast two digits of lever catalog number occupy this position when rotary heads with levers are required.
kSee page 40 for levers.
fSee page 45 for available levers, specifically allowed for the ZCE05 programmable head.
43
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD—Modular
Components
fThe plug-in base recepticale must match the contact pin outs in the body. Only the length of cord is variable. See page 40 for 3-pole plug-
in bases with cord. The 4-pole units and connector versions do not have component modular bases. See pages 34 and 35 for 4 contact
bodies, and pages 38 and 39 for M12 connector bodies.
cAvailable cable lengths:
ZCMC29L•: 1, 2, 3, 5, 7, and 10 m (3.3, 6.6, 9.8, 16.4, 23.0, and 32.8 ft)
ZCMC37L•: 1, 2, and 5 m (3.3, 6.6, and 16.4 ft)
ZCMC39L•: 1, 2, and 5 m (3.3, 6.6, and 16.4 ft)
Plug-in base with PVR cable f
Contact type Diagram Length of PVR cable
m (ft) Catalog number cWeight
lb (kg)
2-pole
2-pole N.C. + N.O.
snap action 1 (3.3) ZCMC21L1 0.22
(0.100)
2-pole N.C. + N.O.
snap action 2 (6.6) ZCMC21L2 0.42
(0.190)
2-pole N.C. + N.O.
snap action 3 (9.8) ZCMC21L3 0.62
(0.280)
2-pole N.C. + N.O.
snap action 5 (16.4) ZCMC21L5 1.00
(0.440)
2-pole N.C. + N.O.
snap action 7 (23.0) ZCMC21L7 1.50
(0.700)
2-pole N.C. + N.O.
snap action 10 (32.8) ZCMC21L10 2.10
(0.970)
2-pole N.C. + N.O.
slow break-before-make 1 (3.3) ZCMC25L1 0.22
(0.100)
2-pole N.C. + N.O.
slow break-before-make 2 (6.6) ZCMC25L2 0.42
(0.190)
2-pole N.C. + N.O.
slow break-before-make 3 (9.8) ZCMC25L3 0.62
(0.280)
2-pole N.C. + N.O.
slow break-before-make 5 (16.4) ZCMC25L5 1.00
(0.440)
2-pole N.C. + N.O.
slow break-before-make 7 (23.0) ZCMC25L7 1.50
(0.700)
2-pole N.C. + N.O.
slow break-before-make 10 (32.8) ZCMC25L10 2.10
(0.970)
ZCMC2kLk
BK-WH BK
BU
BN
GN-YE
BK-WH BK
BU
BN
GN-YE
BK-WH BK
BU
BN
GN-YE
BK-WH BK
BU
BN
GN-YE
BK-WH BK
BU
BN
GN-YE
BK-WH BK
BU
BN
GN-YE
BK-WH BK
BU
BN
GN-YE
BK-WH BK
BU
BN
GN-YE
BK-WH BK
BU
BN
GN-YE
BK-WH BK
BU
BN
GN-YE
BK-WH BK
BU
BN
GN-YE
BK-WH BK
BU
BN
GN-YE
44
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD—Modular
Components
Pre-cabled connection components (CEI cable) (1)
Type of contact Wiring
diagram
Length of CEI
cable, m (ft) Catalog Number Weight
kg (lb)
2-pole
N/C + N/O
snap action
1 (3.28) ZCMC21E1 0.100
(0.220)
2 (6.56) ZCMC21E2 0.190
(0.419)
3 (9.84) ZCMC21E3 0.280
(0.617)
5 (16.40) ZCMC21E5 0.440
(0.970)
7 (22.97) ZCMC21E7 0.700
(1.543)
10 (32.81) ZCMC21E10 0.970
(2.138)
Bodies with gold contacts
Type of contact Positive
operation (2)
Wiring
diagram
Length of cable, m
(ft) Catalog Number Weight
kg (lb)
2-pole
N/C + N/O
snap action —ZCMD61 0.055
(0.121)
N/C + N/C
snap action
—ZCMD69 0.055
(0.121)
N/C + N/O
break before make,
slow break
—ZCMD65 0.055
(0.121)
3-pole
N/C + N/C + N/O
snap action
—ZCMD79 0.055
(0.121)
N/C + N/C + N/O
break before make,
slow break
—ZCMD77 0.055
(0.121)
4-pole
N/C + N/C + N/O + N/O
snap action
1 (3.28) ZCMD81L1 0.160
(0.353)
2 (6.56) ZCMD81L2 0.255
(0.562)
5 (16.40) ZCMD81L5 0.525
(1.157)
1. Cable not UL, CSA certified.
2. bodies with contacts assuring positive opening operation, when properly mounted and using a conforming operator.
BK-WH BK
BU
BN
GN-YE
ZCMC21E•
520719
BK-WH BK
BU
BN
GN-YE
520720
ZCMD6•
ZCMD7•
BK-WH BK
RD
RD-WH
GN-YE
BK-WH BK
BU
BN
GN-YE
RD-WH RD
BU
BN
GN-YE
BK-WH BK
RD-WH RD
BU
BN
GN-YE
BK-WH BK
RD-WH RD
VT
VT-WH
GN-YE
BK-WH BK
BU
BN
520721
ZCMD81L•
45
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD
Bodies with gold contacts, integral connector
Type of contact Positive
operation (1)
Wiring
diagram Connector Catalog Number Weight
kg (lb)
2-pole
N/C + N/O
snap action — M12 5-pin ZCMD61C12 0.065
(0.143)
N/C + N/C
snap action — M12 5-pin ZCMD69C12 0.065
(0.143)
Single-pole
C/O
snap action —M12 4-pin ZCMD61M12 0.065
(0.143)
Accessories
Description Positive
operation (1)
Suitable levers for
use with head Catalog Number Weight
kg (lb)
Rotary head, without lever, spring return,
for actuation from left AND right
or
from left OR right (2)
ZCY12, ZCY15, ZCY16,
ZCY17, ZCY18, ZCY19,
ZCY22, ZCY23, ZCY25,
ZCY26, ZCY39, ZCY53,
ZCY54, ZCY55, ZCY81
ZCE05 0.045
(0.099)
Spacer for mounting
multi-track XCMD —— XCMZ06 0.005
(0.011)
Spacer for angular positioning of heads
with adjustable levers, for values other
than -90°, 0° and 90°
—— XCMZ07 0.005
(0.011)
Bodies with contacts, with rotary head (without operating lever), pre-cabled
Type of contact Positive
operation (1)
Wiring
diagram
Length of cable,
m (ft) Catalog Number Weight
kg (lb)
2-pole
N/C + N/O
snap action 1 (3.28) XCMD2101L1 0.180
(0.397)
N/C + N/O
break before make,
slow break
1 (3.28) XCMD2501L1 0.180
(0.397)
Bodies with contacts, with rotary head (without operating lever), integral connector
Type of contact Positive
operation (1)
Wiring
diagram Connector Catalog Number Weight
kg (lb)
2-pole
N/C + N/O
snap action M12 5-pin XCMD2101C12 0.110
(0.243)
Single-pole
C/O
snap action — M12 4-pin XCMD2101M12 0.110
(0.243)
1. bodies with contacts or head assuring positive opening operation, when properly mounted and using a conforming operator.
2. For programming see page 14.
ZCMD61•••
562245
ZCE05
561408
XCMZ06
566637
XCMZ07
566638
BK-WH BK
BU
BN
GN-YE
XCMD2•01L1
562246
BK-WH BK
BU
BN
GN-YE
562247
XCMD2101•12
46
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD—Connector Cabling Accessories
Catalog Numbers of suitable pre-wired female connectors
Type of connector M12 straight, 4-pin
4 A, 250 V
M12 straight, 5-pin
4 A, 24 V
M12 elbowed, 5-pin
4 A, 24 V
7/8" 16 UN straight,
5-pin, 6 A, 250 V
With cable
L = 2 m (6.56 ft) XZCP1169L2 XZCP1164L2 XZCP1264L2 XZCP1771L2
L = 5 m (16.40 ft) XZCP1169L5 XZCP1164L5 XZCP1264L5 XZCP1771L5
L = 10 m (32.81 ft) XZCP1169L10 XZCP1164L10 XZCP1264L10 XZCP1771L10
Weight, kg (lb) 0.105 (0.231) 0.115 (0.254) 0.115 (0.254) 0.190 (0.419)
Connections
XCMD with connector
4-pin, M12 5-pin, M12 5-pin, 7/8" 16 UN
3 A—250 V
1 = common
2 = N/C
3 = t
4 = N/O
4 A—60 V
XCMD21•• or ZCMD21••
1–2 = N/C
3–4 = N/O
5 = t
XCMD29•• or ZCMD29••
1–2 = N/C
3–4 = N/C
5 = t
6 A—250 V
1–2 = N/C
4–5 = N/O
3 = t
Pre-wired female connectors XZCP
4-pin, M12 5-pin, M12 5-pin, 7/8" 16 UN
1 = brown
2 = blue
3 = yellow/green t
4 = black
1 = brown
2 = white
3 = blue
4 = black
t = yellow/green
1 = black
2 = blue
3 = yellow/green t
4 = brown
5 = white
Dimensions
XZCP116•L• XZCP1264L• XZCP1771L•
L: cable length 2, 5, or 10 m (6.6, 16.4, or 32.8 ft)
Distances required for plug-in connectors
M12 straight connector M12 elbowed connector Connector on flying lead
d: min. 65 mm (2.56 in.),
recommended 69 mm (2.72 in.)
d: min. 42 mm (1.65 in.),
recommended 45 mm (1.77 in.) d: min. 20 mm (0.79 in.)
3
4
2
13
4
2
1
5
24
3
1
3
4
2
13
4
2
1
5
24
3
1
42 L
32
26
L
40
20
55 L
d
d
d
47
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD, Integral or Remote Connector
XCMD2•10M12 XCMD2•11M12 XCMD2•02M12
XCMD2•24M12 XCMD2•F0M12 XCMD2•G1M12
XCMD2•F2M12 XCMD2•45M12 XCMD2•15M12 / 16M12 / 17M12
XCMD2•06M12
1. 2 mounting holes Ø 4.2 mm (0.17 in.), counterbored Ø 8 mm (0.31 in.) by 4 mm (0.16 in.) deep.
e: 8 mm (0.31 in.) max., panel cut-out Ø 12.5 mm (0.49 in.), mounting nut thickness 3.5 mm (0.14 in.).
f: 8 mm (0.31 in.) max., panel cut-out Ø 16.5 mm (0.65 in.), mounting nut thickness 3.5 mm (0.14 in.).
(1)
82
60
50
M12
(1)
92
70
50
(1)
92,4
70,4
50
45
21,4
Ø9
12
85
50
107
(1)
M12x1
24
52
98
e
88
38
50
f
110
M16X1
M12
16 52
30
Ø7
30
88
36
52
e
110
Ø10,6
3,5
M12x1
30
52
16
M12
(1)
115…165
53…103
93…143
31
(1)
34,5
32,4
94
116
54
1,2
204
182
48
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD, Integral or Remote Connector
ZCMD21L08••• + ZCE 10 ZCMD21L08••• + ZCE 11 ZCMD21L08••• + ZCE 02
ZCMD21L08••• + ZCE 24 ZCMD21L08••• + ZCE F0 ZCMD21L08••• + ZCE G1
1. 2 mounting holes Ø 4.2 mm (0.17 in.), counterbored Ø 8 mm (0.31 in.) by 4 mm (0.16 in.) deep.
2. Overall diameter 7.5 mm (0.30 in.).
e: 8 mm (0.31 in.) max., panel cut-out Ø 12.5 mm (0.49 in.), mounting nut thickness 3.5 mm (0.14 in.).
f: 8 mm (0.31 in.) max., panel cut-out Ø 16.5 mm (0.65 in.), mounting nut thickness 3.5 mm (0.14 in.).
60
(1)
(2
)
30
70
(2
)
(1) (1)
(2
)
12
45
19
Ø9
85
(1)
(2)
52
76
24
(2
)
e
38
50
88
(2
)
f
49
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature, Metal
Universal, XCMD, Integral or Remote Connector
ZCMD21L08••• + ZCEF2 ZCMD21L08••• + ZCE01 + ZCY 15/16/17 ZCMD21L08••• + ZCE01 + ZCY 45
ZCMD21L08••• + ZCE06
1. 2 mounting holes Ø 4.2 mm (0.17 in.), counterbored Ø 8 mm (0.31 in.) by 4 mm (0.16 in.) deep.
2. Overall diameter 7.5 mm (0.30 in.).
e: 8 mm (0.31 in.) max., panel cut-out Ø 12.5 mm (0.49 in.), mounting nut thickness 3.5 mm (0.14 in.).
f: 8 mm (0.31 in.) max., panel cut-out Ø 16.5 mm (0.65 in.), mounting nut thickness 3.5 mm (0.14 in.).
36
52
88
(2)
e
(2
)
(1)
32,4
31
54
94
5,5
33
20
(1)
30
16
15°
15°
33,5…83,5
53…103
93…143
Ø16
(2)
(2
)
(1)
40
50
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature, Plastic
XCMN
b XCMN
pre-cabled v With head for linear movement (plunger). Mounting by the body.
Page 52
v With head for linear movement (plunger). Mounting by the head.
Page 52
v With head for rotary movement (lever) or multi-directional.
Page 53
520366
530750
530751
530752
530753
520371
51
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature, Plastic
XCMN
Environmental characteristics
Conforming to standards
Products IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C22-2 n° 14
Machine assemblies IEC 60204-1, EN 60204-1
Product certifications UL, CSA, CCC
Protective treatment Standard version “TC”
Ambient air temperature
Operation - 25…+70 °C (-13…+158 °F)
Storage - 40…+70 °C (-40…+158 °F)
Vibration resistance Conforming to IEC 60068-2-6 5 gn (10…500 Hz)
Shock resistance Conforming to IEC 60068-2-27 25 gn (18 ms)
Electric shock protection Class II conforming to IEC 61140 and NF C 20030
Degree of protection IP 65 conforming to IEC 60529; IK 04 conforming to EN 50102
Materials Bodies Plastic
Heads Zamak® zinc alloy
Contact block characteristics
Rated operational characteristics
a AC-15; B300 (Ue = 240 V, Ie = 1.5 A); Ithe = 6 A
c DC-13; R300 (Ue = 250 V, Ie = 0.1 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
Rated insulation voltage Ui = 400 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Rated impulse withstand voltage U imp = 4 kV conforming to IEC 60947-1, IEC 60664
Short-circuit protection 6 A cartridge fuse type gG (gl)
52
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Miniature, Plastic
XCMN, Pre-Cabled
Type of head Plunger (mounting by the body) Plunger (mounting by the head)
Type of operator Metal end plunger
Steel roller plunger
for
lateral cam
approach
Steel roller plunger
for traverse cam
approach
Thermoplastic roller
lever plunger,
1 direction of actuation
M12 with metal end
plunger
M12 with steel roller
plunger for lateral
cam approach
M12 with steel roller
plunger for traverse
cam approach
Catalog Numbers
2-pole
N/C + N/O
snap action
XCMN2110L1 XCMN2102L1 XCMN2103L1 XCMN2121L1 XCMN21F0L1 XCMN21F2L1 XCMN21F3L1
Weight, kg (lb) 0.080 (0.176) 0.080 (0.176) 0.080 (0.176) 0.090 (0.198) 0.065 (0.143) 0.095 (0.209) 0.095 (0.209)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when properly
mounted and using a conforming operator
Characteristics
Switch actuation On end By 30° cam On end By 30° cam
Type of actuation
Maximum actuation
speed 0.5 m/s (1.64 ft/s) 0.1 m/s (0.33 ft/s) 0.5 m/s (1.64 ft/s) 0.1 m/s (0.33 ft/s)
Minimum
force or
torque
For tripping 8.5 N (1.91 lb) 7 N (1.57 lb) 2.5 N (0.56 lb) 8.5 N (1.91 lb) 7 N (1.57 lb)
For positive
opening 42.5 N (9.55 lb) 35 N (7.87 lb) 12.5 N (2.81 lb) 42.5 N (9.55 lb) 35 N (7.87 lb)
Cabling PvR cable, 4 x 0.75 mm2, length 1 m (3.28 ft)
Dimensions
XCMN2110L1 XCMN2102L1, XCMN2103L1 XCMN21F2L1, XCMN21F3L1
XCMN2121L1 XCMN21F0L1
1. 2 mounting holes Ø 4.2 mm (0.17 in.),
counterbored Ø 8 mm (0.31 in.)
by 4 mm (0.16 in.) deep.
2. Overall diameter 7.5 mm (0.30 in.).
e: 8 mm (0.31 in.) max, panel cut-out Ø 12.5 mm
(0.49 in.), mounting nut thickness 3.5 mm (0.14 in.).
BK-WH BK
BU
BN
1,8
05mm
0,8
B
K-BK-WH
B
N-BU
B
K-BK-WH
B
N-BU
4,2(P) 3,1(A)
B
K-BK-WH
B
N-BU
B
K-BK-WH
B
N-BU 0mm
1,4
7(P) 3,1(A)
B
K-BK-WH
B
N-BU
B
K-BK-WH
B
N-BU 0mm
1,4
7(P)
6,5 (A)
0mm
2,8
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
14 (P)
1,8
05mm
0,8
B
K-BK-WH
B
N-BU
B
K-BK-WH
B
N-BU
4,2(P) 3,1(A)
B
K-BK-WH
B
N-BU
B
K-BK-WH
B
N-BU 0mm
1,4
7(P) 3,1(A)
B
K-BK-WH
B
N-BU
B
K-BK-WH
B
N-BU 0mm
1,4
7(P)
Ø7
20
30
16
50
40
60
20
(1)
(2
)
3,5 Ø11,6
20
30
16
50
40
70,4
30,4
(1)
(2)
M12x1
3,5
e
Ø10,6
30
16
52
88
36
(2)
20
30
16
50
40
(2)
16
39
(1)
M12x1 Ø7
30
16
52
76
24
e
(2)
53
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Miniature, Plastic
XCMN, Pre-Cabled
Type of head Rotary (mounting by the body) Multi-directional
Type of operator Thermoplastic roller
lever
Variable length
thermoplastic roller
lever
Round thermoplastic
rod lever Ø 6 mm
(0.24 in.) (1)
Spring lever with
thermoplastic end (1) Cat’s whisker (1)
Catalog Numbers
2-pole
N/C + N/O
snap action
XCMN2115L1 XCMN2145L1 XCMN2159L1 XCMN2107L1 XCMN2106L1
Weight, kg (lb) 0.100 (0.220) 0.105 (0.231) 0.080 (0.176) 0.085 (0.187) 0.080 (0.176)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening
operation, when properly mounted and using a
conforming operator
1. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mountings.
Characteristics
Switch actuation By 30° cam By any moving part
Type of actuation
Maximum actuation speed 1.5 m/s (4.92 ft/s) 1 m/s (3.28 ft/s) 1 m/s (3.28 ft/s), any direction
Minimum force or torque For tripping 0.1 N•m (0.89 lb-in)
For positive opening 0.5 N•m (4.43 lb-in) — —
Cabling PvR cable, 4 x 0.75 mm2, length 1 m (3.28 ft)
Dimensions
XCMN2115L1 XCMN2159L1 XCMN2107L1
XCMN2145L1 XCMN2106L1
1. 2 mounting holes Ø 4.2 mm (0.17 in.),
counterbored Ø 8 mm (0.31 in.)
by 4 mm (0.16 in.) deep.
2. Overall diameter 7.5 mm (0.30 in.).
BK-WH BK
BU
BN
25˚
090˚
12˚
B
K-BK-WH
B
N-BU
B
K-BK-WH
B
N-BU
70˚(P) 25˚
090˚
12˚
B
K-BK-WH
B
N-BU
B
K-BK-WH
B
N-BU
70˚(P) 25˚
090˚
12˚
BK-BK-WH
BN-BU
BK-BK-WH
BN-BU
20˚
10˚
BK-BK-WH
BU-BN
BK-BK-WH
BU-BN
20˚
10˚
BK-BK-WH
BU-BN
BK-BK-WH
BU-BN
34,4
40
94
54
Ø16
30
32,4
5,5
20
24
16
(1)
31
(2)
40
232
192
30
40,5
20
16
(2)
30
(1)
Ø6
12840
168
20
Ø6,4
30
16
(2)
(1)
5,5
33
20
30
16
33,5…83,5
53…103
93…143
Ø16
(1)
(2)
20
30
16
182
142
Ø1,2
(1)
40
(2)
54
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact
Universal, XCKP and XCKT Plastic / XCKD Metal
b XCKP, XCKD
with 1 cable entry
Conforming to CENELEC EN 50047
v With head for linear movement (plunger). Mounting by the head or by the body.
XCKD XCKP
Pages 56 and 60 Pages 62 and 66
v
With head for rotary movement (lever) or multi-directional. Mounting by the body.
XCKD XCKP
Pages 57 and 61 Pages 63 and 67
b XCKT
with 2 cable entries
Tripping/resetting points and mounting centers conform
to CENELEC EN 50047
v With head for linear movement (plunger). Mounting by the head or by the body.
XCKT
Page 68
v
With head for rotary movement (lever) or multi-directional. Mounting by the body.
XCKT
Page 68
Environmental characteristics
Conforming to standards Products IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C22-2 n° 14
Machine assemblies IEC 60204-1, EN 60204-1
Product certifications UL, CSA, CCC
Protective treatment Standard version “TC”
Ambient air temperature Operation - 25…+70 °C (-13…+158 °F)
Storage - 40…+70 °C (-40…+158 °F)
Vibration resistance Conforming to IEC 60068-2-6 25 gn (10…500 Hz) except switch with head ZCE 24: 20 gn
Shock resistance Conforming to IEC 60068-2-27 50 gn (11 ms) except heads ZCE08: 15 gn (11 ms) and ZCE24: 30 gn (18 ms)
Electric shock protection Class II conforming to IEC 61140 and NF C 20-030 for XCKP and XCKT
Class I conforming to IEC 61140 and NF C 20-030 for XCKD
Degree of protection IP 66 and IP 67 conforming to IEC 60529; IK 04 conforming to EN 50102 for XCKP and XCKT, IK 06
conforming to EN 50102 for XCKD
Repeat accuracy 0.1 mm on the tripping points, with 1 million operating cycles for head with end plunger
Cable entry or
integral connector Depending on model Either: tapped entry for PG 11 or PG 13 conduit thread, tapped ISO M16 x 1.5 or ISO M20 x 1.5,
tapped 1/2" NPT, tapped PF 1/2 (G1/2) or integral M12 connector
Materials XCKD: Zamak® bodies and heads, XCKP and XCKT: plastic bodies, Zamak heads
520353
520354
520355
520356
520357
520358
520359
520360
520361
520362
520363
520364
520365
55
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact
Universal, XCKP and XCKT Plastic / XCKD Metal
Contact block characteristics
Rated operational
characteristics
XE2•P a AC-15; A300 (Ue = 240 V, Ie = 3 A); Ithe = 10 A
c DC-13; Q300 (Ue = 250 V, Ie = 0.27 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
XE3•P a AC-15; B300 (Ue = 240 V, Ie = 1.5 A); Ithe = 6 A
c DC-13; R300 (Ue = 250 V, Ie = 0.1 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
Rated insulation voltage
XE2•P Ui = 500 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
XE3•P Ui = 400 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Rated impulse withstand
voltage
XE2•P U imp = 6 kV conforming to IEC 60947-1, IEC 60664
XE3•P U imp = 4 kV conforming to IEC 60947-1, IEC 60664
Positive operation (depending on model) N/C contacts with positive opening operation conforming to IEC 60 947-5-1 Appendix K, EN 60947-5-1
Resistance across terminals y 25 mΩ conforming to IEC 60255-7 category 3
Short-circuit protection XE2•P 10 A cartridge fuse type gG (gl)
XE3•P 6 A cartridge fuse type gG (gl)
Cabling
(screw clamp terminals)
XE2SP•151 and XE2SP2141 Clamping capacity, min: 1 x 0.34 mm
2
, max: 2 x 1.5 mm
2
XE2NP21•1 and XE2NP31•1 Clamping capacity, min: 1 x 0.5 mm
2
, max: 2 x 2.5 mm
2
XE3NP and XE3SP Clamping capacity, min: 1 x 0.34 mm
2
, max: 1 x 1 mm
2
or 2 x 0.75 mm
2
Minimum actuation speed
(for head with end plunger)
XE2SP•151, XE2SP2141 and XE3SP: 0.01 m/minute (0.03 ft/minute)
XE2NP21•1, XE2NP31•1 and XE3NP: 6 m/minute (19.68 ft/minute)
Electrical durability
•Conforming to IEC 60947-5-1 Appendix C
•Utilization categories AC-15 and DC-13
•Maximum operating rate: 3600 operating cycles/hour
•Load factor: 0.5
XE2SP•151, XE2SP2141 XE2NP21•1, XE2NP31•1
a.c. supply
a 50/60 Hz
o inductive circuit
d.c. supply c
Power switched in W for 5 million operating
cycles.
Power switched in W for 5 million
operating cycles.
Voltage V 24 48 120 Voltage V 24 48 120
oW10 7 4 oW13 9 7
For XE2SP•151 on a or c, N/C and N/O contacts simultaneously loaded to the values shown with reverse polarity.
XE3NP•••• XE3SP••••
a.c. supply
a 50/60 Hz
o inductive circuit
d.c. supply c
Power switched in W for 5 million operating
cycles.
Power switched in W for 5 million
operating cycles.
Voltage V 24 48 120 Voltage V 24 48 120
oW321 oW432
Millions of operating cycles
Current in A
0,1
0,5
1
5
0,5 1 5 10
110 V
48 V
230/400 V
234
Ithe
24 V
Millions of operating cycles
Current in A
0,5 1 2 3 4 5 10
0,1
0,2
0,5
1
5
2
4
3
Ithe
230 V
12/24/48 V
110 V
0,1
0,5
1
5
0,5 1 5 10
110 V
48 V
230/400 V
234
Ithe
24 V
Millions of operating cycles
Current in A
Millions of operating cycles
Current in A
0,5 1 2 3 4 5 10
0,1
0,2
0,5
1
5
2
4
3
Ithe
230 V
110 V
12/24/48 V
56
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact, Metal
Universal, XCKD—Complete Units with 1/2" NPT Cable Entry
Type of head Plunger (mounting by the body)
Form B (1) Form C (1) Form E (1)
Type of operator Metal end plunger Metal end plunger
with elastomer boot Steel roller plunger
Thermoplastic roller
lever plunger,
horizontal actuation
in 1 direction
Thermoplastic roller
lever plunger,
vertical actuation in
1direction
Thermoplastic roller
lever plunger, horiz. or
vert. actuation in
1 direction
Catalog Numbers (2) (3)
2-pole N/C + N/O
snap action (XE2S P2151)
XCKD2110N12 XCKD2111N12 XCKD2102N12 XCKD2121N12 XCKD2127N12 XCKD2128N12
2-pole N/C + N/O
break before make, slow
break (XE2N P2151)
XCKD2510N12 XCKD2511N12 XCKD2502N12 XCKD2521N12 XCKD2527N12 XCKD2528N12
2-pole N/C + N/C
snap action (XE2S P2141)
ZCD29 +
ZCDEN12 +
ZCE10
ZCD29 +
ZCDEN12 +
ZCE11
ZCD29 +
ZCDEN12 +
ZCE02
ZCD29 +
ZCDEN12 +
ZCE21
ZCD29 +
ZCDEN12 +
ZCE27
ZCD29 +
ZCDEN12 +
ZCE28
2-pole N/C + N/C
simultaneous, slow break
(XE2N P2141)
ZCD27 +
ZCDEN12 +
ZCE10
ZCD27 +
ZCDEN12 +
ZCE11
ZCD27 +
ZCDEN12 +
ZCE02
ZCD27 +
ZCDEN12 +
ZCE21
ZCD27 +
ZCDEN12 +
ZCE27
ZCD27 +
ZCDEN12 +
ZCE28
3-pole N/C + N/C + N/O
snap action (XE3SP2141)
ZCD39 +
ZCDEN12 +
ZCE10
ZCD39 +
ZCDEN12 +
ZCE11
ZCD39 +
ZCDEN12 +
ZCE02
ZCD39 +
ZCDEN12 +
ZCE21
ZCD39 +
ZCDEN12 +
ZCE27
ZCD39 +
ZCDEN12 +
ZCE28
3-pole N/C + N/C + N/O
break before make, slow
break
(XE3N P2141)
ZCD37 +
ZCDEN12 +
ZCE10
ZCD37 +
ZCDEN12 +
ZCE11
ZCD37 +
ZCDEN12 +
ZCE02
ZCD37 +
ZCDEN12 +
ZCE21
ZCD37 +
ZCDEN12 +
ZCE27
ZCD37 +
ZCDEN12 +
ZCE28
Weight, kg (lb) 0.180 (0.397) 0.180 (0.397) 0.185 (0.408) 0.195 (0.430) 0.190 (0.419) 0.195 (0.430)
Contact operation contact closed
contact open
(A)(B) = cam displacement
(P) = positive opening point
N/C contact with positive opening
operation, when properly mounted and using a
conforming operator
Characteristics
Switch actuation On end By 30° cam
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1 m/s (3.28 ft/s)
Minimum force
or torque
For tripping 15 N (3.37 lb) 12 N (2.70 lb) 6 N (1.35 lb)
For positive opening 45 N (10.12 lb) 36 N (8.09 lb) 18 N (4.05 lb)
Cable entry (3) 1 entry tapped M16 x 1.5 mm for ISO cable entry, clamping capacity 4 to 8 mm (0.16 to 0.31 in.)
1. Form conforming to EN 50047. See page 22.
2. Switches with gold contacts or ring type connections: please consult your local sales office.
3. For an entry tapped for a PG 11 conduit thread, replace N12 in the catalog number with G11. Examples: XCKD2110N12 becomes XCKD2110G11, ZCDEN12 becomes ZCDEG11.
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P) 6,5(A)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14
6,5(B)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14
9,8(A)
0mm
4,9
22,5(P)
2
1-22
1
3-14
2
1-22
1
3-14
13
14
22 21
1,8
05mm
3
3,2(P)
21-22
13-14
1,8
05mm
3
3,2(P)
21-22
13-14
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14
6,5(A)
0mm
10,5
11,3(P)
21-22
13-14
6,5(B)
0mm
10,5
11,3(P)
21-22
13-14
9,8(A)
0mm
16,1
17,2(P)
21-22
13-14
12 11
22 21
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
3,1(A)
11-12
21-22
11-12
21-220mm
1,5
7,8(P) 6,5(A)
0mm
3
15,7(P)
11-12
21-22
11-12
21-22
6,5(B)
0mm
3
15,7(P)
11-12
21-22
11-12
21-22
9,8(A)
0mm
4,9
22,5(P)
11-12
21-22
11-12
21-22
12 11
22 21
1,8
05mm
3,2(P)
11-12
21-22
1,8
05mm
3,2(P)
11-12
21-22
5,6(P)
05mm
3,1
11-12
21-22
6,6(A) 11,6(P)
05mm
11-12
21-22
6,6(B) 11,6(P)
05mm
11-12
21-22
5,3(A)
05mm
11-12
21-22
32 31
22 21
1314
1,8 4,6(P)
05mm
0,9
21-22
31-32
13-14
21-22
31-32
13-14
1,8 4,6(P)
05mm
0,9
21-22
31-32
13-14
21-22
31-32
13-14
3,1(A) 7,8(P)
0mm
1
,
5
21-22
31-32
13-14
21-22
31-32
13-14
6,5(A) 15,7(P)
0mm
3
21-22
31-32
13-14
21-22
31-32
13-14
6,5(B) 15,7(P)
0mm
3
21-22
31-32
13-14
21-22
31-32
13-14
9,8(A) 22,5(P)
0mm
4
,
9
21-22
31-32
13-14
21-22
31-32
13-14
32 31
22 21
1314
3,2(P)1,8
05mm
3
21-22
31-32
13-14
3,2(P)1,8
05mm
3
21-22
31-32
13-14
5,6(P)3,1(A)
0mm
5,2
21-22
31-32
13-14
11,3(P)6,5(A)
0mm
10,5
21-22
31-32
13-14
11,3(P)6,5(B)
0mm
10,5
21-22
31-32
13-14
17,2(P)9,8(A)
0mm
16,1
21-22
31-32
13-14
57
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact, Metal
Universal, XCKD—Complete Units with 1/2" NPT Cable Entry
Type of head Plunger (mounting by the head) Rotary (mounting by the body) Multi-directional
Form A (1)
Type of operator M18 with metal end
plunger
M18 with steel
roller plunger
Thermoplastic roller
lever
Variable length
thermoplastic roller
lever
Thermoplastic roller
lever,
Ø 50 mm (1.97 in.)
Variable length
thermoplastic roller lever,
Ø 50 mm (1.97 in.)
Cat’s whisker (3)
Catalog Numbers (2) (4)
2-pole N/C + N/O
snap action
(XE2S P2151)
XCKD21H0N12 XCKD21H2N12 XCKD2118N12 XCKD2145N12 XCKD2139N12 XCKD2149N12 XCKD2106N12
2-pole N/C + N/O
break before
make, slow
break (XE2N
P2151)
XCKD25H0N12 XCKD25H2N12 XCKD2518N12 XCKD2545N12 XCKD2539N12 XCKD2549N12 XCKD2506N12
2-pole N/C +
N/C
snap action
(XE2S P2141)
ZCD29 +
ZCDEN12 +
ZCEH0
ZCD29 +
ZCDEN12 +
ZCEH2
ZCD29 +
ZCDEN12 +
ZCE01 +
ZCY18
ZCD29 +
ZCDEN12 +
ZCE01 +
ZCY45
ZCD29 +
ZCDEN12 +
ZCE 01 +
ZCY39
ZCD29 +
ZCDEN12 +
ZCE01 +
ZCY49
ZCD29 +
ZCDEN12 +
ZCE06
2-pole N/C +
N/C
simultaneous
,
slow break
(XE2N P2141)
ZCD27 +
ZCDEN12 +
ZCEH0
ZCD27 +
ZCDEN12 +
ZCEH2
ZCD27 +
ZCDEN12 +
ZCE01 +
ZCY18
ZCD27 +
ZCDEN12 +
ZCE01 +
ZCY45
ZCD27 +
ZCDEN12 +
ZCE01 +
ZCY39
ZCD27 +
ZCDEN12 +
ZCE01 +
ZCY49
ZCD27 +
ZCDEN12 +
ZCE06
3-pole N/C +
N/C + N/O
snap action
(XE3S P2141)
ZCD39 +
ZCDEN12 +
ZCEH0
ZCD39 +
ZCDEN12 +
ZCEH2
ZCD39 +
ZCDEN12 +
ZCE01 +
ZCY18
ZCD39 +
ZCDEN12 +
ZCE01 +
ZCY45
ZCD39 +
ZCDEN12 +
ZCE01 +
ZCY39
ZCD39 +
ZCDEN12 +
ZCE01 +
ZCY49
ZCD39 +
ZCDEN12 +
ZCE06
3-pole N/C +
N/C + N/O
break before
make, slow
break
(XE3N P2141)
ZCD37+
ZCDEN12 +
ZCEH0
ZCD37 +
ZCDEN12 +
ZCEH2
ZCD37 +
ZCDEN12 +
ZCE01 +
ZCY18
ZCD37 +
ZCDEN12 +
ZCE01 +
ZCY45
ZCD37 +
ZCDEN12 +
ZCE01 +
ZCY39
ZCD37 +
ZCDEN12 +
ZCE01 +
ZCY49
ZCD37 +
ZCDEN12 +
ZCE06
Weight, kg (lb) 0.220 (0.485) 0.220 (0.485) 0.225 (0.496) 0.235 (0.518) 0.235 (0.518) 0.245 (0.540) 0.175 (0.386)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when properly
mounted and using a conforming operator
Characteristics
Switch actuation On end By 30° cam By any moving part
Type of actuation
Maximum actuation
speed 0.5 m/s (1.64 ft/s) 1.5 m/s (4.92 ft/s) 1 m/s (3.28 ft/s),
any direction
Minimum
force or
torque
For tripping 15 N (3.37 lb) 10 N (2.25 lb) 0.1 N•m (0.89 lb-in) 0.13 N•m (1.15 lb-in)
For positive
opening 45 N (10.12 lb) 36 N (8.09 lb) 0.25 N•m (2.21 lb-in) —
Cable entry (4) 1 entry tapped M16 x 1.5 mm for ISO cable entry, clamping capacity 4 to 8 mm (0.16 to 0.31 in.)
1. Form conforming to EN 50047. See page 22.
2. Switches with gold contacts or ring type connections: please consult your local sales office.
3. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mountings.
4. For an entry tapped for a PG 11 conduit thread, replace N12 in the catalog number with G11. Examples: XCKD21H0N12 becomes XCKD21H0G11, ZCDEN12 becomes ZCDEG11.
Note: For more information, consult pages 63, 70–71.
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P)
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
13
14
22 21
1,8
05mm
3
3,2(P)
21-22
13-14
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14 0
21-22
13-14
46
0
21-22
13-14
46
0
21-22
13-14
46
0
21-22
13-14
46
0
21-22
13-14
12 11
22 21
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
3,1(A)
11-12
21-22
11-12
21-220mm
1,5
7,8(P)
0
11-12
21-22
11-12
21-22
70
0
11-12
21-22
11-12
21-22
70
0
11-12
21-22
11-12
21-22
70
0
11-12
21-22
11-12
21-22
70
0
11-12
11-12
21-22
21-22
12 11
22 21
1,8
05mm
3,2(P)
11-12
21-22
5,6(P)
05mm
3,1
11-12
21-22
0
11-12
21-22
46
0
11-12
21-22
46
0
11-12
21-22
46
0
11-12
21-22
46
0
11-12
21-22
32 31
22 21
1314
1,8 4,6(P)
05mm
0,9
21-22
31-32
13-14
21-22
31-32
13-14
3,1(A) 7,8(P)
0mm
1,5
21-22
31-32
13-14
21-22
31-32
13-14
25˚ 70˚(P)
090˚
12˚
21-22
31-32
13-14
21-22
31-32
13-14
25˚ 70˚(P)
090˚
12˚
21-22
31-32
13-14
21-22
31-32
13-14
25˚ 70˚(P)
090˚
12˚
21-22
31-32
13-14
21-22
31-32
13-14
25˚ 70˚(P)
090˚
12˚
21-22
31-32
13-14
21-22
31-32
13-14
20˚
0
15˚
21-22
31-32
13-14
21-22
31-32
13-14
32 31
22 21
1314
3,2(P)1,8
05mm
3
21-22
31-32
13-14
5,6(P)3,1(A)
0mm
5,2
21-22
31-32
13-14
46˚(P)25˚
042˚ 90˚
21-22
31-32
13-14
46˚(P)25˚
042˚ 90˚
21-22
31-32
13-14
46˚(P)25˚
042˚ 90˚
21-22
31-32
13-14
46˚(P)25˚
042˚ 90˚
21-22
31-32
13-14
20˚
045˚
21-22
31-32
13-14
58
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact, Metal
Universal, XCKD—Complete Units with 1/2" NPT Cable Entry
ZCD2• + ZCDEN12 / ZCD3• + ZCDEN12 ZCE10 ZCE11
ZCE02 ZCE21 ZCE27
ZCE28 ZCEH0 ZCEH2
1. Tapped entry for ISO M16 x 1.5 or PG 11 conduit thread.
2. 2 elongated holes Ø 4.3 x 6.3 mm (0.17 x 0.25 in.) on 22 mm (0.87 in.) centers, 2 holes Ø 4.3 mm (0.17 in.) on 20 mm (0.79 in.) centers.
3. 2 x Ø 3 holes for support studs, depth 4 mm (0.16 in.).
4. Mounting nut thickness 3.5 mm (0.14 in.).
(1)
(2)
(3)
2
10
19
51
12,5
20
12,5 8
30
3,5
30,5
12,5
11,6
12,5
5,5
20,2
16
39
5,5
12
22
41
13
2,5
=
12,5
36,2
16
7
5,5
48
29
2,5=
22
M18x1
(4)
26
12,5
7
38
M18x1
(4)
3,5
12,5
59
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact, Metal
Universal, XCKD—Complete Units with 1/2" NPT Cable Entry
ZCE01 + ZCY18 ZCE01 + ZCY45 ZCE01 + ZCY39
ZCE01 + ZCY49 ZCE06
40
5,5
24
33
52,5
12,5
37,5
5,5
12,5
16
33…83,5
52,5…103
10
42
58
77,5
12,5
10
16
40
12,5
142
12,5
60
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact, Metal
Universal, XCKD—Integral M12 Connector
Type of head Plunger (mounting by the body)
Form B (1) Form C (1) Form E (1)
Type of operator Metal end plunger Metal end plunger
with elastomer boot Steel roller plunger
Thermoplastic roller
lever plunger,
horizontal actuation
in 1 direction
Thermoplastic roller
lever plunger,
vertical actuation
in 1 direction
Thermoplastic roller
lever plunger,
horiz. or vert. actu-
ation in 1 direction
Catalog Numbers
2-pole N/C + N/O snap action (XE2S P2151)
XCKD2110M12 XCKD2111M12 XCKD2102M12 XCKD2121M12 XCKD2127M12 XCKD2128M12
2-pole N/C + N/C snap action (XE2S P2141) ZCD29M12 +
ZCE10
ZCD29M12 +
ZCE11
ZCD29M12 +
ZCE02
ZCD29M12 +
ZCE21
ZCD29M12 +
ZCE27
ZCD29M12 +
ZCE28
Weight, kg (lb) 0.190 (0.419) 0.190 (0.419) 0.195 (0.430) 0.205 (0.452) 0.200 (0.441) 0.205 (0.452)
Contact operation contact closed
contact open
(A) (B) = cam displacement
(P) = positive opening point
1. Form conforming to EN 50047. See page 22.
Characteristics
Switch actuation On end By 30° cam
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1 m/s (3.28 ft/s)
Minimum force or
torque
For tripping 15 N (3.37 lb) 12 N (2.70 lb) 6 N (1.35 lb)
For positive opening 45 N (10.12 lb) 36 N (8.09 lb) 18 N (4.05 lb)
Connection M12 5-pin connector, Ui = 60 V, Ie = 4 A maximum, Ith = 4 A
Connections
Integral M12 connector
XE2SP2151
1-2: N/C
3-4: N/O
5: t
XE2SP2141
1-2: N/C
3-4: N/C
5: t
Dimensions
ZCD2•M12 ZCE10 ZCE11 ZCE02 ZCE21
ZCE27 ZCE28 ZCEH0
1. 2 elongated holes Ø 4.3 x 6.3 mm (0.17 x 0.25 in.) on 22 mm (0.87 in.) centers,
2 holes Ø 4.3 mm (0.17 in.) on 20 mm (0.79 in.) centers.
2. 2 x Ø 3 holes for support studs, depth 4 mm (0.16 in.).
3. Mounting nut thickness 3.5 mm (0.14 in.).
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P) 6,5(A)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14
6,5(B)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14
9,8(A)
0mm
4,9
22,5(P)
21-22
13-14
21-22
13-14
12 11
22 21
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
3,1(A)
11-12
21-22
11-12
21-220mm
1,5
7,8(P) 6,5(A)
0mm
3
15,7(P)
11-12
21-22
11-12
21-22
6,5(B)
0mm
3
15,7(P)
11-12
21-22
11-12
21-22
9,8(A)
0mm
4,9
22,5(P)
11-12
21-22
11-12
21-22
12
43
5
(1)
2
M12
30 31
20/22
65
77
(2)
10
19
51
12,5
20
Ø7
30
12,5
12,5
Ø11,6
3,5
30,5
16
Ø14
12,5
5,5
39
20,2
Ø14
5,5
12
22
41
13
2,5 = Ø22
12,5
36,2
16
6
48
7
29
2,5
=M18x1
(3)
26
12,5
Ø7
61
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact, Metal
Universal, XCKD—Integral M12 Connector
Type of head Plunger (mounting by the head) Rotary (mounting by the body) Multi-directional
Form A (1)
Type of operator M18 with metal end
plunger
M18 with steel
roller plunger
Thermoplastic roller
lever
Variable length
thermoplastic roller
lever
Thermoplastic roller
lever,
Ø 50 mm (1.97 in.)
Variable length
thermoplastic roller
lever, Ø 50 mm (1.97 in.)
Cat’s whisker (2)
Catalog Numbers
2-pole N/C + N/O
snap action
(XE2S P2151)
XCKD21H0M12 XCKD21H2M12 XCKD2118M12 XCKD2145M12 XCKD2139M12 XCKD2149M12 XCKD2106M12
2-pole N/C + N/C
snap action
(XE2S P2141)
ZCD29M12 +
ZCEH0
ZCD29M12 +
ZCEH2
ZCD29M12 +
ZCE01 + ZCY18
ZCD29M12 +
ZCE01 + ZCY45
ZCD29M12 +
ZCE01 + ZCY39
ZCD29M12 +
ZCE01 + ZCY49
ZCD29M12 +
ZCE06
Weight, kg (lb) 0.235 (0.518) 0.235 (0.518) 0.220 (0.485) 0.220 (0.485) 0.220 (0.485) 0.220 (0.485) 0.185 (0.408)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
1. Form conforming to EN 50047. See page 22.
2. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mounting.
Characteristics
Switch actuation On end By 30° cam By any moving part
Type of actuation
Maximum actuation
speed 0.5 m/s (1.64 ft/s) 1.5 m/s (4.92 ft/s) 1 m/s (3.28 ft/s),
any direction
Minimum
force or
torque
For tripping 15 N (3.37 lb) 10 N (2.25 lb) 0.1 N•m (0.89 lb-in) 0.13 N•m (1.15 lb-in)
For positive
opening 45 N (10.12 lb) 36 N (8.09 lb) 0.25 N•m (2.21 lb-in) —
Connection M12 5-pin connector, Ui = 60 V, Ie = 4 A maximum, Ith = 4 A
Dimensions
ZCE01 + ZCY18 ZCE01 + ZCY45 ZCE01 + ZCY39 ZCE01 + ZCY49 ZCE06
ZCEH2
3. Mounting nut thickness 3.5 mm (0.14 in.)
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P)
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
12 11
22 21
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
3,1(A)
11-12
21-22
11-12
21-220mm
1,5
7,8(P)
0
11-12
21-22
11-12
21-22
70
0
11-12
21-22
11-12
21-22
70
0
11-12
21-22
11-12
21-22
70
0
11-12
21-22
11-12
21-22
70
0
11-12
11-12
21-22
21-22
40
5,5 24
33
52,5
12,5
19
37,5
5,5
12,5
16
33…83,5
52,5…103
Ø16
10
42
58
77,5
12,5
10
16
54…100,5
73,5…120
40
12,5
Ø50
142
12,5
Ø1,2
38
M18x1
(3)
3,5
12,5
62
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact, Plastic
Universal, XCKP—Complete Units with 1/2" NPT Cable Entry
Type of head Plunger (mounting by the body)
Form B (1) Form C (1) Form E (1)
Type of operator
Metal end plunger Metal end plunger
with elastomer boot Steel roller plunger
Thermoplastic roller
lever plunger,
horizontal actuation
in 1 direction
Thermoplastic roller
lever plunger,
vertical actuation in
1direction
Thermoplastic roller
lever plunger, horiz.
or vert. actuation in
1direction
Catalog Numbers (2) (3)
2-pole N/C + N/O
snap action (XE2S P2151)
XCKP2110N12 XCKP2111N12 XCKP2102N12 XCKP2121N12 XCKP2127N12 XCKP2128N12
2-pole N/C + N/O
break before make, slow break
(XE2N P2151)
XCKP2510N12 XCKP2511N12 XCKP2502N12 XCKP2521N12 XCKP2527N12 XCKP2528N12
2-pole N/C + N/C
snap action (XE2S P2141)
ZCP29 +
ZCPEN12 +
ZCE10
ZCP29 +
ZCPEN12 +
ZCE11
ZCP29 +
ZCPEN12 +
ZCE02
ZCP29 +
ZCPEN12 +
ZCE21
ZCP29 +
ZCPEN12 +
ZCE27
ZCP29 +
ZCPEN12 +
ZCE28
2-pole N/C + N/C
simultaneous, slow break
(XE2N P2141)
ZCP27 +
ZCPEN12 +
ZCE10
ZCP27 +
ZCPEN12 +
ZCE11
ZCP27 +
ZCPEN12 +
ZCE02
ZCP27 +
ZCPEN12 +
ZCE21
ZCP27 +
ZCPEN12 +
ZCE27
ZCP27 +
ZCPEN12 +
ZCE28
3-pole N/C + N/C + N/O
snap action (XE3S P2141)
ZCP39 +
ZCPEN12 +
ZCE10
ZCP39 +
ZCPEN12 +
ZCE11
ZCP39 +
ZCPEN12 +
ZCE02
ZCP39 +
ZCPEN12 +
ZCE21
ZCP39 +
ZCPEN12 +
ZCE27
ZCP39 +
ZCPEN12 +
ZCE28
3-pole N/C + N/C + N/O
break before make, slow
break (XE3N P2141)
ZCP37 +
ZCPEN12 +
ZCE10
ZCP37 +
ZCPEN12 +
ZCE11
ZCP37 +
ZCPEN12 +
ZCE02
ZCP37 +
ZCPEN12 +
ZCE21
ZCP37 +
ZCPEN12 +
ZCE27
ZCP37 +
ZCPEN12 +
ZCE28
Weight, kg (lb) 0.090 (0.198) 0.090 (0.198) 0.095 (0.209) 0.105 (0.231) 0.100 (0.220) 0.105 (0.231)
Contact operation contact closed
contact open
(A)(B) = cam displacement
(P) = positive opening point
N/C contact with positive opening
operation, when properly mounted and
using a conforming operator
Characteristics
Switch actuation On end By 30° cam
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1 m/s (3.28 ft/s)
Minimum force or
torque
For tripping 15 N (3.37 lb) 12 N (2.70 lb) 6 N (1.35 lb)
For positive opening 45 N (10.12 lb) 36 N (8.09 lb) 18 N (4.05 lb)
Cable entry (3) 1 entry tapped M16 x 1.5 mm for ISO cable entry, clamping capacity 4 to 8 mm (0.16 to 0.31 in.)
1. Form conforming to EN 50047. See page 22.
2. Switches with gold contacts or ring type connections: please consult your local sales office.
3. For an entry tapped for a PG 11 conduit thread, replace N12 in the catalog number with G11. Examples: XCKP2110N12 becomes XCKP2110G11, ZCPEN12 becomes ZCPEG11.
Note: For more information, consult pages 63, 70–71.
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P) 6,5(A)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14
6,5(B)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14
9,8(A)
0mm
4,9
22,5(P)
21-22
13-14
21-22
13-14
13
14
22 21
1,8
05mm
3
3,2(P)
21-22
13-14
1,8
05mm
3
3,2(P)
21-22
13-14
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14
6,5(A)
0mm
10,5
11,3(P)
21-22
13-14
6,5(B)
0mm
10,5
11,3(P)
21-22
13-14
9,8(A)
0mm
16,1
17,2(P)
21-22
13-14
12 11
22 21
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
3,1(A)
11-12
21-22
11-12
21-220mm
1,5
7,8(P) 6,5(A)
0mm
3
15,7(P)
11-12
21-22
11-12
21-22
6,5(B)
0mm
3
15,7(P)
11-12
21-22
11-12
21-22
9,8(A)
0mm
4,9
22,5(P)
11-12
21-22
11-12
21-22
12 11
22 21
1,8
05mm
3,2(P)
11-12
21-22
1,8
05mm
3,2(P)
11-12
21-22
5,6(P)
0mm
3,1
11-12
21-22
6,6(A) 11,6(P)
0mm
11-12
21-22
6,6(B) 11,6(P)
0mm
11-12
21-22
5,3(A)
0mm
11-12
21-22
32 31
22 21
1314
1,8 4,6(P)
05mm
09
21-22
31-32
13-14
21-22
31-32
13-14
1,8 4,6(P)
05mm
09
21-22
31-32
13-14
21-22
31-32
13-14
3,1(A) 7,8(P)
0mm
1,5
21-22
31-32
13-14
21-22
31-32
13-14
6,5(A) 15,7(P)
0mm
3
21-22
31-32
13-14
21-22
31-32
13-14
6,5(B) 15,7(P)
0mm
3
21-22
31-32
13-14
21-22
31-32
13-14
9,8(A) 22,5(P)
0mm
4,9
21-22
31-32
13-14
21-22
31-32
13-14
32 31
22 21
1314
3,2(P)1,8
05mm
3
21-22
31-32
13-14
3,2(P)1,8
05mm
3
21-22
31-32
13-14
5,6(P)3,1(A)
0mm
5,2
21-22
31-32
13-14
11,3(P)6,5(A)
0mm
10,5
21-22
31-32
13-14
11,3(P)6,5(B)
0mm
10,5
21-22
31-32
13-14
17,2(P)9,8(A)
0mm
16,1
21-22
31-32
13-14
63
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact, Plastic
Universal, XCKP—Complete Units with 1/2" NPT Cable Entry
Type of head Plunger (mounting by the head) Rotary (mounting by the body) Multi-directional
Form A (1)
Type of operator M18 with metal end
plunger
M18 with steel
roller plunger
Thermoplastic roller
lever
Variable length
thermoplastic roller
lever
Thermoplastic roller
lever,
Ø 50 mm (1.97 in.)
Variable length
thermoplastic roller lever,
Ø 50 mm (1.97 in.)
Cat’s whisker (4)
Catalog Numbers (2)
2-pole N/C + N/O
snap action
(XE2S P2151)
XCKP21H0N12 XCKP21H2N12 XCKP2118N12 XCKP2145N12 XCKP2139N12 XCKP2149N12 XCKP2106N12
2-pole N/C + N/O
break before
make, slow
break
(XE2NP2151)
XCKP25H0N12 XCKP25H2N12 XCKP2518N12 XCKP2545N12 XCKP2539N12 XCKP2549N12 XCKP2506N12
2-pole N/C +
N/C snap action
(XE2SP2141)
ZCP29 +
ZCPEN12 +
ZCEH0
ZCP29 +
ZCPEN12 +
ZCEH2
ZCP29 +
ZCPEN12 +
ZCE01 +
ZCY18
ZCP29 +
ZCPEN12 +
ZCE01 +
ZCY45
ZCP29 +
ZCPEN12 +
ZCE 01 +
ZCY39
ZCP29 +
ZCPEN12 +
ZCE01 +
ZCY49
ZCP29 +
ZCPEN12 +
ZCE06
2-pole N/C + N/C
simultaneous,
slow break
(XE2NP2141)
ZCP27 +
ZCPEN12 +
ZCEH0
ZCP27 +
ZCPEN12 +
ZCEH2
ZCP27 +
ZCPEN12 +
ZCE01 +
ZCY18
ZCP27 +
ZCPEN12 +
ZCE01 +
ZCY45
ZCP27 +
ZCPEN12 +
ZCE01 +
ZCY39
ZCP27 +
ZCPEN12 +
ZCE01 +
ZCY49
ZCP27 +
ZCPEN12 +
ZCE06
3-pole
N/C + N/C +
N/O snap
action
(XE3SP2141)
ZCP39 +
ZCPEN12 +
ZCEH0
ZCP39 +
ZCPEN12 +
ZCEH2
ZCP39 +
ZCPEN12 +
ZCE01 +
ZCY18
ZCP39 +
ZCPEN12+
ZCE01 +
ZCY45
ZCP39 +
ZCPEN12 +
ZCE01 +
ZCY39
ZCP39 +
ZCPEN12 +
ZCE01 +
ZCY49
ZCP39 +
ZCPEN12 +
ZCE06
3-pole
N/C + N/C +
N/O
break before
make, slow
break
(XE3NP2141)
ZCP37+
ZCPEN12 +
ZCEH0
ZCP37 +
ZCPEN12 +
ZCEH2
ZCP37 +
ZCPEN12 +
ZCE01 +
ZCY18
ZCP37 +
ZCPEN12 +
ZCE01 +
ZCY45
ZCP37 +
ZCPEN12 +
ZCE01 +
ZCY39
ZCP37 +
ZCPEN12 +
ZCE01 +
ZCY49
ZCP37 +
ZCPEN12 +
ZCE06
Weight, kg (lb) 0.130 (0.287) 0.130 (0.287) 0.135 (0.298) 0.145 (0.320) 0.145 (0.320) 0.155 (0.342) 0.085 (0.187)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when properly
mounted and using a conforming operator
Characteristics
Switch actuation On end By 30° cam By any moving part
Type of actuation
Maximum actuation
speed 0.5 m/s (1.64 ft/s) 1.5 m/s (4.92 ft/s) 1 m/s (3.28 ft/s),
any direction
Minimum
force or
torque
For tripping 15 N (3.37 lb) 10 N (2.25 lb) 0.1 N•m (0.89 lb-in) 0.13 N•m (1.15 lb-in)
For positive
opening 45 N (10.12 lb) 36 N (8.09 lb) 0.25 N•m (2.21 lb-in) —
Cable entry (3) 1 entry tapped M16 x 1.5 mm for ISO cable entry, clamping capacity 4 to 8 mm (0.16 to 0.31 in.)
1. Form conforming to EN 50047. See page 22.
2. Switches with gold contacts or ring type connections: please consult your local sales office.
3. For an entry tapped for a PG 11 conduit thread, replace N12 in the catalog number with G11. Examples: XCKP21H0N12 becomes XCKP21H0G11, ZCPEN12 becomes ZCPEG11.
4. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mountings.
Note: For more information, consult pages 63, 70–71.
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P)
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
13
14
22 21
1,8
0 5mm
3
3,2(P)
21-22
13-14
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14
0
21-22
13-14
46
0
21-22
13-14
46
0
21-22
13-14
46
0
21-22
13-14
46
0
21-22
13-14
12 11
22 21
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
3,1(A)
11-12
21-22
11-12
21-220mm
1,5
7,8(P)
0
11-12
21-22
11-12
21-22
70
0
11-12
21-22
11-12
21-22
70
0
11-12
21-22
11-12
21-22
70
0
11-12
21-22
11-12
21-22
70
0
11-12
11-12
21-22
21-22
12 11
22 21
1,8
05mm
3,2(P)
11-12
21-22
5,6(P)
0mm
3,1
11-12
21-22
0
11-12
21-22
46
0
11-12
21-22
46
0
11-12
21-22
46
0
11-12
21-22
46
0
11-12
21-22
32 31
22 21
1314
1,8 4,6(P)
05mm
09
21-22
31-32
13-14
21-22
31-32
13-14
3,1(A) 7,8(P)
0mm
1,5
21-22
31-32
13-14
21-22
31-32
13-14
25˚ 70˚(P)
090˚
12˚
21-22
31-32
13-14
21-22
31-32
13-14
25˚ 70˚(P)
090˚
12˚
21-22
31-32
13-14
21-22
31-32
13-14
25˚ 70˚(P)
090˚
12˚
21-22
31-32
13-14
21-22
31-32
13-14
25˚ 70˚(P)
090˚
12˚
21-22
31-32
13-14
21-22
31-32
13-14
20˚
0
15˚
21-22
31-32
13-14
21-22
31-32
13-14
32 31
22 21
1314
3,2(P)1,8
05mm
3
21-22
31-32
13-14
5,6(P)3,1(A)
0mm
5,2
21-22
31-32
13-14
46˚(P)25˚
042˚ 90˚
21-22
31-32
13-14
46˚(P)25˚
042˚ 90˚
21-22
31-32
13-14
46˚(P)25˚
042˚ 90˚
21-22
31-32
13-14
46˚(P)25˚
042˚ 90˚
21-22
31-32
13-14
20˚
045˚ ˚
21-22
31-32
13-14
64
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact, Plastic
Universal, XCKP—Complete Units with 1/2" NPT Cable Entry
ZCP2• + ZCPEN12 / ZCP3• + ZCPEN12 ZCE10 ZCE28
ZCE11
ZCE02 ZCE21 ZCE27
ZCE06 ZCEH0 ZCE01 + ZCY18
ZCEH2
ZCE01 + ZCY49 ZCE01 + ZCY45
ZCE01 + ZCY39
1. Tapped entry for ISO M16 x 1.5 or PG 11 conduit thread.
2. 2 elongated holes Ø 4.3 x 6.3 mm (0.17 x 0.25 in.) on 22 mm (0.87 in.) centers,
2 holes Ø 4.3 mm (0.17 in.) on 20 mm (0.79 in.) centers.
3. 2 x Ø 3 holes for support studs,
depth 4 mm (0.16 in.).
4. Mounting nut thickness 3.5 mm (0.14 in.).
2
(2)
(1)
20/22
12,5
15˚
15˚
30
31
19
65
(3)
10
51
12,5
20
=
2,5
12,5
36,2
16
713
5,5
48
29
2,5
=
Ø22
12,5
30
3,5
30,5
12,5
Ø 11,6
5,5 12,5
20,2
16
39
Ø14
5,5
12
22
41
142
12,5
M18x1
(4)
26
12,5
Ø7
40
5,5
24
33
52,5
12,5
38
M18x1
(4)
3,5
12,5
10
16
40
12,5
37,5
5,5
12,5
16
52,5…103
10
42
58
77,5
12,5
65
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact, Metal and Plastic
Universal, XCKD, XCKP, and XCKT
Catalog Number Interpretation
For Interpretation of the Catalog Number Only
XCK P 21 10 N12
XCK—Assembled unit Contact Description Conduit Threads
ZCP—Plastic body components 21—1 N.O. + 1 N.C. Snap Action Silver F12—PF 1/2
ZCD—Metal body components 25—1 N.O. + 1 N.C. Slow Make/Break Silver G11—PG 11
ZCT—Wide body components 26—1 N.O. + 1 N.C. Overlapping Cont. Gold G13—PG 13.5
ZCPE—Plastic conduit components 27—1 N.C. + 1 N.C. Slow Make/Break Silver c—4- or 5-Pin Connector
ZCDE—Metal conduit components 28—1 N.O. + 1 N.O. Slow Make/Break Silver N12—1/2 NPT
29—1 N.C. + 1 N.C. Snap Action Silver P16—ISO M16
31—2 N.O. + 1 N.C. Snap Action Silver P20—M20
35—2 N.O. + 1 N.C. Slow Make/Break Silver c
37—1 N.O. + 2 N.C. Slow Make/Break Silver cHead Assembly
39—1 N.O. + 2 N.C. Snap Action Silver 01—Rotary Head without Lever Arm
41—2 N.O. + 2 N.C. Snap Action Silver c02—Steel Top Roller Plunger
61—1 N.O. + 1 N.C. Snap Action Gold 05—Rotary Head Programmable
65—1 N.O. + 1 N.C. Slow Make/Break Gold c06—Cat Whisker
Body 66—1 N.O. + 1 N.C. Overlapping Cont. Gold c07—Spring Rod with Plastic End c
P—Plastic 67—1 N.C. + 1 N.C. Slow Make/Break Gold c08—Spring Rod c
D—Metal 68—1 N.O. + 1 N.O. Slow Make/Break Gold 09—Maint. Rotary without Arm c
T—Plastic wide body 69—1 N.C. + 1 N.C. Snap Action Gold 10—Top Push Rod Plunger
71—2 N.O. + 1 N.C. Snap Action Gold c11—Booted Top Push Rod Pl.
75—2 N.O. + 1 N.C. Slow Make/Break Gold c13—Top Ball Bearing Plunger c
77—1 N.O. + 2 N.C. Slow Make/Break Gold c14—Adjustable Top Plunger c
79—1 N.O. + 2 N.C. Snap Action Gold c21—One-way Horiz. Plastic Roller
81—2 N.O. + 2 N.C. Snap Action Gold c24—Retractable Steel Roller, 9 mm (0.35 in.)
C1—1 N.O. + 1 N.C. Snap Action Quick Connect c27—One-way Vert. Plastic Roller
C9—1 N.C. + 1 N.C. Snap Action Quick Connect c28—One-way Horiz. or Vert. Roller
29—Booted Top Roller Plunger c
62—Adjust. Side Push Rod Pl. c
63—Side Push Rod Plunger c
64—Horiz. Side Roller Plunger c
65—Vertical Side Roller Plunger c
66—Side Ball Bearing Plunger c
67—Horizontal Cat Whisker c
F0—M12 Threaded Plunger Head c
Important Note:
Use for interpretation only. Not all possibilities are shown and not all combination of
components are available. Not all switches are modular. See additional information in
this catalog. For interpretation of heads and levers see page 70–71.
F2—M12 Threaded Roller Plunger Head c
G1—M16 Threaded Booted Plunger Head c
H0—M18 Threaded Plunger Head c
H2—M18 Threaded Roller Plunger Head c
cCall your local field sales office for availability.
66
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact, Plastic
Universal, XCKP—Integral M12 Connector
Type of head Plunger (mounting by the body)
Form B (1) Form C (1) Form E (1)
Type of operator Metal end plunger Metal end plunger
with elastomer boot
Steel roller
plunger
Thermoplastic roller
lever plunger,
horizontal actuation
in 1 direction
Thermoplastic roller
lever plunger,
vertical actuation in
1 direction
Thermoplastic roller
lever plunger,
horiz. or vert. actu-
ation in 1 direction
Catalog Numbers
2-pole N/C + N/O
snap action (XE2S P2151)
XCKP2110M12 XCKP2111M12 XCKP2102M12 XCKP2121M12 XCKP2127M12 XCKP2128M12
2-pole N/C + N/C
snap action (XE2S P2141)
ZCP29M12 +
ZCE10
ZCP29M12 +
ZCE11
ZCP29M12 +
ZCE02
ZCP29M12 +
ZCE21
ZCP29M12 +
ZCE27
ZCP29M12 +
ZCE28
Weight, kg (lb) 0.100 (0.220) 0.100 (0.220) 0.100 (0.220) 0.110 (0.243) 0.110 (0.243) 0.110 (0.243)
Contact operation contact closed
contact open
(A)(B) = cam displacement
(P) = positive opening point
N/C contact with positive opening
operation, when properly mounted and
using a conforming operator
1. Form conforming to EN 50047. See page 22.
Characteristics
Switch actuation On end By 30° cam
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1 m/s (3.28 ft/s)
Minimum force or
torque
For tripping 15 N (3.37 lb) 12 N (2.70 lb) 6 N (1.35 lb)
For positive opening 45 N (10.12 lb) 36 N (8.09 lb) 18 N (4.05 lb)
Connection M12 4-pin connector, Ui = 250 V, Ie = 3 A maximum, Ith = 3 A
Connections
Integral M12 connector
XE2S P2151
1-2: N/C
3-4: N/O
XE2S P2141
1-2: N/C
3-4: N/C
Dimensions
ZCP2•M12 ZCE10 ZCE11 ZCE02 ZCE21
ZCE27 ZCE28 ZCEH0
1. 2 elongated holes Ø 4.3 x 6.3 mm (0.17 x 0.25 in.) on 22 mm (0.87 in.)
(0.87 in.) centers, 2 holes Ø 4.3 mm (0.17 in.) on 20 mm (0.79 in.) ctrs.
2. 2 x Ø 3 mm (0.12 in.) holes for support studs, depth 4 mm (0.16 in.).
3. Mounting nut thickness 3.5 mm (0.14 in.).
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P) 6,5(A)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14
6,5(B)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14
9,8(A)
0mm
4,9
22,5(P)
21-22
13-14
21-22
13-14
12 11
22 21
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
3,1(A)
11-12
21-22
11-12
21-220mm
1,5
7,8(P) 6,5(A)
0mm
3
15,7(P)
11-12
21-22
11-12
21-22
6,5(B)
0mm
3
15,7(P)
11-12
21-22
11-12
21-22
9,8(A)
0mm
4,9
22,5(P)
11-12
21-22
11-12
21-22
12
43
30
M12
65
77
2
20/22
31
==
12,5
(1)
(2)
10
19
51
12,5
20
Ø7
30
12,5
12,5
Ø11,6
3,5
30,5
16
Ø14
12,5
5,5
39
20,2
Ø14
5,5
12
22
41
13
2,5 = Ø22
12,5
36,2
16
6
48
7
29
2,5
=M18x1
(3)
26
12,5
Ø7
67
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact, Plastic
Universal, XCKP—Integral M12 Connector
Type of head Plunger (mounting by the head) Rotary (mounting by the body) Multi-directional
Form A (1)
Type of operator M18 with metal end
plunger
M18 with steel
roller plunger
Thermoplastic roller
lever
Variable length
thermoplastic roller
lever
Thermoplastic roller
lever,
Ø 50 mm (1.97 in.)
Variable length
thermoplastic roller
lever, Ø 50 mm (1.97 in.)
Cat’s whisker (2)
Catalog Numbers
2-pole N/C + N/O
snap action
(XE2SP2151)
XCKP21H0M12 XCKP21H2M12 XCKP2118M126 XCKP2145M12 XCKP2139M12 XCKP2149M12 XCKP2106M126
2-pole N/C + N/C
snap action
(XE2S P2141)
ZCP29M12 +
ZCEH0
ZCP29M12 +
ZCEH2
ZCP29M12 +
ZCE01 +
ZCY18
ZCP29M12 +
ZCE01 +
ZCY45
ZCP29M12 +
ZCE01 +
ZCY39
ZCP29M12 +
ZCE01 +
ZCY49
ZCP29M12 +
ZCE06
Weight, kg (lb) 0.140 (0.309) 0.140 (0.309) 0.140 (0.309) 0.150 (0.331) 0.155 (0.342) 0.160 (0.353) 0.090 (0.198)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when properly
mounted and using a conforming operator
1. Form conforming to EN 50047. See page 22.
2. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mountings.
Characteristics
Switch actuation On end By 30° cam By any moving part
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1.5 m/s (4.92 ft/s) 1 m/s (3.28 ft/s),
any direction
Minimum
force or
torque
For tripping 15 N (3.37 lb) 10 N (2.25 lb) 0.1 N•m (0.89 lb-in) 0.13 N•m (1.15 lb-in)
For positive
opening 45 N (10.12 lb) 36 N (8.09 lb) 0.25 N•m (2.21 lb-in) —
Connection M12 4-pin connector, Ui = 250 V, Ie = 3 A maximum, Ith = 3 A
Dimensions
ZCE01 + ZCY18 ZCE01 + ZCY45 ZCE01 + ZCY39 ZCE01 + ZCY49 ZCE06
3. Mounting nut thickness
3.5 mm (0.14 in.).
ZCEH2
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P)
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
12 11
22 21
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
3,1(A)
11-12
21-22
11-12
21-220mm
1,5
7,8(P)
0
11-12
21-22
11-12
21-22
70
0
11-12
21-22
11-12
21-22
70
0
11-12
21-22
11-12
21-22
70
0
11-12
21-22
11-12
21-22
70
0
11-12
11-12
21-22
21-22
40
5,5
24
33
52,5
12,5
19
37,5
5,5
12,5
16
33…83,5
52,5…103
Ø16
10
42
58
77,5
12,5
10
16
54…100,5
73,5…120
40
12,5
Ø50
142
12,5
Ø1,2
38
M18x1
(3)
3,5
12,5
68
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact, Plastic
Universal, XCKT—Complete Units with Two Cable Entries and 1/2" NPT Adapter
Type of head Plunger (mounting by the body) Multi-directional
Form B (1) Form C (1) Form E (1)
Type of operator Metal end plunger Metal end plunger with
elastomer boot Steel roller plunger
Thermoplastic roller
lever
plunger, horizontal
actuation
in 1 direction
Cat’s whisker (4)
Catalog Numbers (2) (3)
2-pole N/C + N/O
snap action
(XE2SP3151)
XCKT2110N12 XCKT2111N12 XCKT2102N12 XCKT2121N12 XCKT2106N12
2-pole N/C + N/O
break before make,
slow break
(XE2NP3151)
ZCT25N12 +
ZCE10
ZCT25N12 +
ZCE11
ZCT25N12 +
ZCE02
ZCT25N12 +
ZCE21
ZCT25N12 +
ZCE06
2-pole N/C + N/O
make before break,
slow break
(XE2N P3161)
ZCT26N12 +
ZCE10
ZCT26N12 +
ZCE11
ZCT26N12 +
ZCE02
ZCT26N12 +
ZCE21
ZCT26N12 +
ZCE06
2-pole N/C + N/C
simultaneous,
slow break
(XE2N P3141)
ZCT27N12 +
ZCE10
ZCT27N12 +
ZCE11
ZCT27N12 +
ZCE02
ZCT27N12 +
ZCE21
ZCT27N12 +
ZCE06
2-pole N/O + N/O
simultaneous,
slow break
(XE2NP3131)
ZCT28N12 +
ZCE10
ZCT28N12 +
ZCE11
ZCT28N12 +
ZCE02
ZCT28N12 +
ZCE21
ZCT28N12 +
ZCE06
Weight, kg (lb) 0.100 (0.220) 0.100 (0.220) 0.105 (0.231) 0.115 (0.254) 0.095 (0.209)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when
properly mounted and using a conforming operator
Characteristics
Switch actuation On end By 30° cam By any moving part
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1 m/s (3.28 ft/s) 1 m/s (3.28 ft/s),
any direction
Minimum force or
torque
For tripping 15 N (3.37 lb) 12 N (2.70 lb) 6 N (1.35 lb) 0.3 N•m (2.66 lb-in)
For positive opening 45 N (10.12 lb) 36 N (8.09 lb) 18 N (4.05 lb) —
Cable entry (3) 2 entries tapped M16 x 1.5 for ISO cable entry. Clamping capacity 4 to 8 mm (0.16 to 0.31 in.) (1 entry fitted with blanking plug).
1. Form conforming to EN 50047. See page 22.
2. Switches with gold contacts or ring connections: please consult your local sales office.
3. For cable entries tapped for a PG 11 conduit thread, replace N12 in the catalog
number with G11. Example: XCKT2110N12 becomes XCKT2110G11.
4. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mountings.
Dimensions
ZCT2•N12 ZCE10 ZCE11 ZCE21
ZCE02 ZCE06
1. 2 tapped entries for ISO M16 x 1.5 or PG 11 conduit thread.
2. 4 elongated holes Ø 4.3 x 6.3 mm (0.17 x 0.25 in.) on 22/42 mm (0.87/1.65 in.) ctrs.,
4 holes Ø 4.3 mm (0.17 in.) on 20/40 mm (0.79/1.57 in.) ctrs.
3. 2 x Ø 3 holes for support studs, depth 4 mm (0.16 in.).
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P) 6,5(A)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14
0
21-22
13-14
21-22
13-14
13
14
22 21
1,8
05mm
3
3,2(P)
21-22
13-14
1,8
05mm
3
3,2(P)
21-22
13-14
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14
6,5(A)
0mm
10,5
11,3(P)
21-22
13-14 0
21-22
13-14
22 21
14 13
3
05mm
1,8
4,4(P)
21-22
13-14
3
05mm
1,8
4,4(P)
21-22
13-14
5,2
0mm
3,1
7,6(P)
21-22
13-14
10,9(A)
0mm
6,6
16(P)
21-22
13-14
0
21-22
13-14
12 11
22 21
1,8
05mm
3,2(P)
11-12
21-22
1,8
05mm
3,2(P)
11-12
21-22
5,6(P)
0mm
3,1
11-12
21-22
6,6(A) 11,6(P)
0mm
11-12
21-22 0
11-12
21-22
1314
24 23
1,8
05mm
13-14
23-24
1,8
05mm
13-14
23-24
3,1(A)
0mm
13-14
23-24
6,6(A)
0mm
13-14
23-24 0
13-14
23-24
20/22
40/42
30
58
51
2
==
12,5
37,6
10
(2)
(1)
15˚
15˚
(3)
40
20
12,5
Ø7
30
12,5
16
39
3,5
30,5
12,5
Ø11,6
12,5
142
Ø
1,2
69
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact, Plastic
Universal, XCKT—Complete Units with Two Cable Entries and 1/2" NPT Adapter
Type of head Plunger (mounting by the head) Rotary (mounting by the body)
Form A (1)
Type of operator M18 with metal end
plunger
M18 with steel roller
plunger Thermoplastic roller lever Variable length
thermoplastic roller lever
Thermoplastic roller lever,
Ø 50 mm (1.97 in.)
Catalog Numbers (2) (3)
2-pole N/C + N/O
snap action
(XE2S P3151)
XCKT21H0N12 XCKT21H2N12 XCKT2118N12 XCKT2145N12 XCKT2139N12
2-pole N/C + N/O
break before make,
slow break
(XE2N P3151)
ZCT25N12 +
ZCEH0
ZCT25N12 +
ZCEH2
ZCT25N12 +
ZCE01 + ZCY18
ZCT25N12 +
ZCE01 + ZCY45
ZCT25N12+
ZCE01 + ZCY39
2-pole N/O + N/C
make before break,
slow break
(XE2N P3161)
ZCT26N12 +
ZCEH0
ZCT26N12 +
ZCEH2
ZCT26N12 +
ZCE01 + ZCY18
ZCT26N12 +
ZCE01 + ZCY45
ZCT26N12 +
ZCE01 + ZCY39
2-pole N/C + N/C
simultaneous,
slow break
(XE2N P3141)
ZCT27N12 +
ZCEH0
ZCT27N12 +
ZCEH2
ZCT27N12 +
ZCE01 + ZCY18
ZCT27N12 +
ZCE01 + ZCY45
ZCT27N12+
ZCE01 + ZCY39
2-pole N/O + N/O
simultaneous,
slow break
(XE2NP3131)
ZCT28N12 +
ZCEH0
ZCT28N12 +
ZCEH2
ZCT28N12 +
ZCE01 + ZCY18
ZCT28N12 +
ZCE01 + ZCY45
ZCT28N12 +
ZCE01 + ZCY39
Weight, kg (lb) 0.145 (0.320) 0.145 (0.320) 0.145 (0.320) 0.155 (0.342) 0.160 (0.353)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when
properly mounted and using a conforming operator
Characteristics
Switch actuation On end By 30° cam
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1.5 m/s (4.92 ft/s)
Minimum force or
torque
For tripping 15 N (3.37 lb) 10 N (2.25 lb) 0.1 N•m (0.89 lb-in)
For positive opening 45 N (10.12 lb) 36 N (8.09 lb) 0.25 N•m (2.21 lb-in)
Cable entry (3) 2 entries tapped M16 x 1.5 for ISO cable entry. Clamping capacity 4 to 8 mm (0.16 to 0.31 in.) (1 entry fitted with blanking plug).
1. Form conforming to EN 50047. See page 22.
2. Switches with gold contacts or ring type connections: please consult your local sales office.
3. For cable entries tapped for a PG 11 conduit thread, replace N12 in the catalog number with G11. Example: XCKT21H0N12 becomes XCKT21H0G11.
Dimensions
ZCEH0 ZCE01 + ZCY18 ZCE01 + ZCY39 ZCE01 + ZCY45
ZCEH2
4. Mounting nut thickness 3.5 mm (0.14 in.)
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P)
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
13
14
22 21
1,8
05mm
3
3,2(P)
21-22
13-14
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14
0
21-22
13-14
46
0
21-22
13-14
46
0
21-22
13-14
46
22 21
14 13
3
05mm
1,8
4,4(P)
21-22
13-14
5,2
0mm
3,1
7,6(P)
21-22
13-14
0
21-22
13-14
0
21-22
13-14
0
21-22
13-14
12 11
22 21
1,8
05mm
3,2(P)
11-12
21-22
5,6(P)
0mm
3,1
11-12
21-22
0
11-12
21-22
46
0
11-12
21-22
46
0
11-12
21-22
46
1314
24 23
1,8
05mm
13-14
23-24
3,1(A)
0mm
13-14
23-24 0
13-14
23-24
90˚ 0
13-14
23-24
90˚ 0
13-14
23-24
90˚
12,5
26
M18x1
(4)
Ø7
33
52,5
40
5,5
24
12,5
12,5
42
58
77,5
10 Ø50
37,5
12,5
16
33…83,5
52,5…103
5,5 Ø16
3,5
38
12,5
M18x1
(4)
70
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact, Metal and Plastic
Universal, XCKD, XCKP, and XCKT—Modular
ZCE H0 ZCE H2
ZCE 02 ZCE 29
ZCE 10 ZCE 11 ZCE 13ZCE 14
ZCE 07 ZCE 08ZCE 06
ZCE 21 ZCE 27 ZCE 28ZCE 24
ZCE 62
ZCE 63ZCE 64 ZCE 65 ZCE 66
ZCP 21M12
ZCP 29M12
ZCP EP16
ISO M16 x 1.5
ZCP EP20
ISO M20 x 1.5
ZCP EG13
Pg 13.5
ZCP EN12
1/2" NPT
ZCP EG11
Pg 11
ZCP EF12
PF 1/2 (G 1/2)
ISO M16 x 1.5
Pg 11
1/2” NPT
ZCE 67
Thermoplastic roller
lever plunger,
horizontal or vertical
actuation
Thermoplastic roller
lever plunger,
horizontal
actuation
Thermoplastic
roller lever plunger,
vertical
actuation
Retractable
steel roller
lever plunger
Side metal
plunger,
adjustable Side
metal
plunger
Side steel
roller plunger,
horizontal
Side steel
roller plunger,
vertical
Side steel
ball bearing
plunger
M18 with metal
end plunger
M18 with steel
roller plunger
Steel roller
plunger
Steel roller plunger
with elastomer
boot
Spring rod with
thermoplastic
end
Spring
rod
Cat’s
whisker
Metal end
plunger
Metal end plunger
with elastomer
boot
Steel ball
bearing plunger
Metal end
plunger,
adjustable
Side cat’s
whisker
Plastic bodies with integral
M12 connector, with:
N/C + N/O
snap action contact
Plastic bodies
with contacts (1)
for use in
conjunction
with cable entry
(see below)
Plastic bodies with contacts (1)
with 2 cable entries
Cable entry:
1. For further details, see page 72.
2. Cannot be used on bodies: ZCD21, ZCP21, ZCT21, ZCD29, ZCP29, ZCD31, ZCP31, ZCD39.ZCP39, ZCD2•M12, ZCP2•M12.
PG 11 conduit entries convert
to 1/2" NPT using adapter
DE9RA1012 (included)
N/C + N/C
snap action contact
71
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact, Metal and Plastic
Universal, XCKD, XCKP, and XCKT—Modular
ZCD EP16
ISO M16 x 1.5
ZCD EP20
ISO M20 x 1.5
ZCD EG11
Pg 11
ZCD EG13
Pg 13.5
ZCD EN12
1/2" NPT
ZCD EF12
PF 1/2 (G1/2)
ZCY 39
ZCY 49 ZCY 69
ZCE 01
ZCE 09
ZCY 71ZCY 61
ZCY 19 ZCY 12 ZCY 15 ZCY 16ZCY 18
ZCY 17 ZCY 25 ZCY 26 ZCY 23
ZCY 44 ZCY 45 ZCY 46 ZCY 48
ZCY 22 ZCY 81 ZCY 91
ZCY 54 ZCY 55 ZCY 59
ZCY 53
ZCD 29M12
ZCD 21M12 ZCD
Round rod lever,
steel, Ø 3 (0.12)
L = 125 (4.92)
Square rod lever,
steel, U 3 (0.12)
L = 125 (4.92)
Round rod lever,
glass fibre,
Ø 3 (0.12)
L = 125 (4.92)
Round rod lever,
thermoplastic, Ø 6 (0.24)
L = 200 (7.87)
Ceramic
roller
lever
Spring lever
with
thermoplastic
end
Spring–
rod lever,
metal
Variable
length
thermoplastic
roller lever,
Ø 50 (1.97)
Variable length
thermoplastic
roller lever,
Ø 50 (1.97), with
adjustable track
Variable length
thermoplastic
roller lever, with
pliable lever
Variable length
thermoplastic
roller lever
Variable length
steel roller lever
Variable length
steel roller lever,
with pliable lever
Thermoplastic
roller lever,
Ø 50 (1.97)
Thermoplastic
roller lever,
track: 24/40
(0.94/1.57)
Steel roller
lever,
track: 24/40
(0.94/1.57)
Steel ball bearing
mounted roller
lever, track:
24/40
(0.94/1.57)
Thermoplastic
roller lever,
track:
29/36
(1.14/1.42)
Steel roller
lever, track:
29/36
(1.14/1.42)
Spring return,
for actuation
from left AND
right
Stay put,
for actuation
from left
AND right
(2)
Thermoplastic
roller lever,
track: 21/44
(0.83/1.73)
Steel ball bearing
mounted roller
lever, track: 21/44
(0.83/1.73)
Forked arm with
rollers, 2 track, track:
25/39 (0.98/1.54)
Steel roller
lever, track:
21/44
(0.83/1.73)
Steel ball bearing
mounted roller
lever, track: 29/36
(1.14/1.42)
Forked arm with
rollers, 1 track,
track: 32 (1.26)
Metal bodies with integral
M12 connector, with:
N/C + N/O
snap action contact
Metal bodies with contacts (1)
for use in conjunction with cable
entry (see below)
Cable entry:
N/C + N/C
snap action contact
Dimensions: mm (in.)
72
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact, Metal and Plastic
Universal, XCKD, XCKP, and XCKT—Modular
Bodies with contacts, types XCKD and XCKP(1)
Type of contact Positive
operation (2)
Function
diagram
Body
material Catalog Number Weight
kg (lb)
2-pole
N/C + N/O
snap action
(XE2SP2151)
Metal ZCD21 0.140
(0.309)
Plastic ZCP21 0.070
(0.154)
N/C + N/C
snap action
(XE2SP2141)
Metal ZCD29 0.140
(0.309)
Plastic ZCP29 0.070
(0.154)
N/C + N/O
break before make,
slow break
(XE2NP2151)
Metal ZCD25 0.140
(0.309)
Plastic ZCP25 0.070
(0.154)
N/O + N/C
make before break,
slow break
(XE2NP2161)
Metal ZCD26 0.140
(0.309)
Plastic ZCP26 0.070
(0.154)
N/C + N/C
simultaneous,
slow break
(XE2NP2141)
Metal ZCD27 0.140
(0.309)
Plastic ZCP27 0.070
(0.154)
N/O + N/O
simultaneous,
slow break
(XE2NP2131)
—
Metal ZCD28 0.140
(0.309)
Plastic ZCP28 0.070
(0.154)
3-pole
N/C + N/O + N/O
snap action
(XE3SP2151)
Metal ZCD31 0.140
(0.309)
Plastic ZCP31 0.070
(0.154)
N/C + N/C + N/O
snap action
(XE3SP2141)
Metal ZCD39 0.140
(0.309)
Plastic ZCP39 0.070
(0.154)
N/C + N/C + N/O
break before make,
slow break
(XE3NP2141)
Metal ZCD37 0.140
(0.309)
Plastic ZCP37 0.070
(0.154)
N/C + N/O + N/O
break before make,
slow break
(XE3NP2151)
Metal ZCD35 0.140
(0.309)
Plastic ZCP35 0.070
(0.154)
1. Bodies with gold contacts or eyelet type connections: please consult your local sales office.
2. : bodies with contacts assuring positive opening operation, when properly mounted and using a conforming operator.
520710
ZCD••
1314
22 21
12 11
22 21
13
14
22 21
13
14
22 21
12 11
22 21
1314
24 23
22 21
1314
3334
520711
ZCP••
32 31
22 21
1314
32 31
22 21
1314
22 21
1314
3334
73
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact, Metal and Plastic
Universal, XCKD, XCKP, and XCKT—Modular
Bodies with contacts, type XCKT plastic, 2 cable entries
Type of contact Positive
operation (1)
Function
diagram
Cable
entries Catalog Number Weight
kg (lb)
2-pole
N/C + N/O
snap action
(XE2SP3151)
ISO M16 x 1.5 ZCT21P16 0.085
(0.187)
PG 11 ZCT21G11 0.085
(0.187)
N/C + N/O
break before make,
slow break
(XE2NP3151)
ISO M16 x 1.5 ZCT25P16 0.085
(0.187)
PG 11 ZCT25G11 0.085
(0.187)
N/C + N/C
simultaneous,
slow break
(XE2NP3141)
ISO M16 x 1.5 ZCT27P16 0.085
(0.187)
PG 11 ZCT27G11 0.085
(0.187)
N/O + N/O
simultaneous,
slow break
(XE2NP3131)
—ISO M16x1.5ZCT28P16 0.085
(0.187)
PG 11 ZCT28G11 0.085
(0.187)
N/O + N/C
make before break,
slow break
(XE2NP3161)
ISO M16 x 1.5 ZCT26P16 0.085
(0.187)
PG 11 ZCT26G11 0.085
(0.187)
Bodies with contacts, type XCKT, plastic, 2 cable entries with 1/2" NPT adapter
Type of contact Positive
operation (1) Function diagram Catalog Number Weight
kg (lb)
2-pole
N/C + N/O
snap action
(XE2SP3151)
ZCT21N12 0.130
(0.287)
N/C + N/O
break before make,
slow break
(XE2NP3151)
ZCT25N12 0.130
(0.287)
N/C + N/C
simultaneous,
slow break
(XE2N P3141)
ZCT27N12 0.130
(0.287)
N/O + N/O
simultaneous,
slow break
(XE2NP3131)
—ZCT28N12 0.130
(0.287)
N/O + N/C
make before break,
slow break
(XE2NP3161)
ZCT26N12 0.130
(0.287)
1. : bodies with contact assuring positive opening operation, when properly mounted and using a conforming operator.
1314
22 21
561390
ZCT•••
13
14
22 21
12 11
22 21
1314
24 23
13
14
22 21
1314
22 21
561387
ZCT••N12
13
14
22 21
12 11
22 21
1314
24 23
13
14
22 21
74
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact, Metal and Plastic
Universal, XCKD, XCKP, and XCKT—Modular
Accessories
Description Suitable levers
for use with head Unit catalog number Weight
kg (oz)
Rotary head,
without lever,
spring return,
for actuation from
left AND right
or
left OR right (1)
ZCY12, ZCY15, ZCY16, ZCY17,
ZCY18, ZCY19, ZCY22, ZCY23,
ZCY25, ZCY26, ZCY39, ZCY53,
ZCY54, ZCY55, ZCY81
ZCE05 0.045
(1.59)
Tap-off terminal (for XCKT) Sold in lots of 10 XALZ09 0.010
(0.35)
Spacer for angular positioning of heads with
adjustable levers, for values other than -90°, 0°
and 90°
—XCMZ07 0.002
(0.07)
Adapter for 1/2" NPT conduit
Converts PG 11 conduit entries to 1/2" NPT Sold in lots of 10 DE9RA1012 0.050
(1.76)
Bodies with contacts, type XCKP plastic, with rotary head (without operating lever)
Type of contact Function
diagram
Positive
operation (2)
Cable
entry Catalog Number Weight
kg (lb)
2-pole
N/C + N/O
snap action
(XE2SP2151)
1/2" NPT XCKP2101N12 0.115
(0.254)
PG 11 XCKP2101G11 0.115
(0.254)
M12 connector XCKP2101M12 0.125
(0.276)
N/C + N/O
break before make,
slow break
(XE2NP2151)
1/2" NPT XCKP2501N12 0.115
(0.254)
PG 11 XCKP2501G11 0.115
(0.254)
Bodies with contacts, type XCKD metal, with rotary head
(without operating lever)
Type of contact Function
diagram
Positive
operation (2)
Cable
entry Catalog Number Weight
kg (lb)
2-pole
N/C + N/O
snap action
(XE2SP2151)
1/2" NPT XCKD2101N12 0.185
(0.408)
PG 11 XCKD2101G11 0.185
(0.408)
M12 connector XCKD2101M12 0.195
(0.430)
N/C + N/O
break before make,
slow break
(XE2NP2151)
1/2" NPT XCKD2501N12 0.185
(0.408)
PG 11 XCKD2501G11 0.185
(0.408)
561427
ZCE05
DE9RA1012
561392
1314
22 21
XCK•2•01••
561388
13
14
22 21
1314
22 21
13
14
22 21
75
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact, Metal and Plastic
Universal, XCKD, XCKP, and XCKT—Modular
Contact blocks with screw clamp terminals for XCKD and XCKP
Type of contact Positive
operation (1) Function diagram Catalog number for
standard contacts
Weight
kg (lb)
2-pole
N/C + N/O
snap action XE2SP2151 0.020
(0.044)
N/C + N/C
simultaneous,
snap action
XE2SP2141 0.020
(0.044)
N/C + N/O
break before make,
slow break
XE2NP2151 0.020
(0.044)
N/O + N/C
make before break,
slow break
XE2NP2161 0.020
(0.044)
N/C + N/C
simultaneous,
slow break
XE2NP2141 0.020
(0.044)
N/O + N/O
simultaneous,
slow break
—XE2NP2131 0.020
(0.044)
3-pole
N/C + N/O + N/O
snap action XE3SP2151 0.035
(0.077)
N/C + N/C + N/O
snap action XE3SP2141 0.035
(0.077)
N/C + N/C + N/O
break before make,
slow break
XE3NP2141 0.035
(0.077)
N/C + N/O + N/O
break before make,
slow break
XE3NP2151 0.035
(0.077)
Contact blocks with screw clamp terminals for XCKT
Type of contact Positive
operation (1) Function diagram Catalog number for
standard contacts
Weight
kg (lb)
2-pole
N/C + N/O
snap action XE2SP3151 0.015
(0.033)
N/C + N/O
break before make,
slow break
XE2NP3151 0.015
(0.033)
N/O + N/C
make before break,
slow break
XE2NP3161 0.015
(0.033)
N/C + N/C
simultaneous,
slow break
XE2NP3141 0.015
(0.033)
N/O + N/O
simultaneous,
slow break
—XE2NP3131 0.015
(0.033)
1. : contact blocks assuring positive opening operation, when properly mounted and using a conforming operator.
1314
22 21
XE2••21••
561393
12 11
22 21
13
14
22 21
13
14
22 21
12 11
22 21
1314
24 23
22 21
1314
3334
XE3••21••
561394
32 31
22 21
1314
32 31
22 21
1314
22 21
1314
3334
1314
22 21
13
14
22 21
13
14
22 21
12 11
22 21
1314
24 23
76
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact with Manual Reset
Application, XCDR—Complete Switches, Metal, with One Cable Entry, 1/2" NPT
Type of head Plunger (mounting by the body) Rotary (mounting by the body)
Type of operator Metal end plunger Steel roller
plunger
Thermoplastic
roller lever plunger,
horizontal actuation
in 1 direction
Thermoplastic
roller lever plunger,
vertical actuation
in 1 direction
Thermoplastic roller
lever Steel roller lever
Catalog numbers of complete switches with one 1/2" NPT cable entry
2-pole N/C + N/O
snap action
(XE2SP2151)
XCDR2110N12 XCDR2102N12 XCDR2121N12 XCDR2127N12 XCDR2118N12 XCDR2119N12
2-pole N/C + N/O
break before make,
slow break
(XE2NP2151)
XCDR2510N12 XCDR2502N12 XCDR2521N12 XCDR2527N12 XCDR2518N12 XCDR2519N12
Weight, kg (lb) 0.215 (0.474) 0.220 (0.485) 0.225 (0.496) 0.225 (0.496) 0.255 (0.562) 0.255 (0.562)
Catalog numbers of complete switches with one PG 13.5 cable entry
For complete switches with 1 PG 13.5 cable entry, replace N12 with G13.
Example: XCDR 2110P20 becomes XCDR 2110G13.
Catalog numbers of complete switches with one P20 cable entry
For complete switches with 1 ISO M20 x 1.5 cable entry, replace N12 with P20.
Example: XCDR 2110N12 becomes XCDR 2110P20.
Contact operation contact closed
contact open
(A) (B) = cam displacement
(P) = positive opening point
N/C contact with positive opening
operation, when properly mounted and
using a conforming operator
Characteristics
Switch actuation On end By 30° cam
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1 m/s (3.28 ft/s) 1.5 m/s (4.92 ft/s)
Minimum force
or torque
For tripping 15 N (3.37 lb) 12 N (2.70 lb) 6 N (1.35 lb) 0.1 N•m (0.89 lb-in)
For positive opening 45 N (10.12 lb) 36 N (8.09 lb) 18 N (4.05 lb) 0.25 N•m (2.21 lb-in)
Cable entry
1 entry tapped M20 x 1.5 mm for ISO cable entry, clamping capacity 7 to 13 mm (0.28 to 0.51 in.), or
1 entry tapped PG 13.5, clamping capacity 9 to 12 mm (0.35 to 0.47 in.), or
1 entry tapped for 1/2" NPT (USAS B2-1) conduit
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P) 6,5(A)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14
6,5(B)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
1314
22 21
1,8
0 5mm
3
3,2(P)
21-22
13-14
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14
6,5(A)
0mm
10,5
11,3(P)
21-22
13-14
6,5(B)
0mm
10,5
11,3(P)
21-22
13-14
0
21-22
13-14
46
0
21-22
13-14
46
77
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact with Manual Reset
Application, XCDR—Complete Switches, Metal, with One Cable Entry, 1/2" NPT
Dimensions
XCDR2•10••• XCDR2•02••• XCDR2•21•••
1. Tapped entry for ISO M20 x 1.5 or PG 13.5 conduit thread
or 1/2" NPT conduit
2. 2 elongated holes Ø 4.3 x 6.3 mm (0.17 x 0.25 in.)
on 22 mm (0.87 in.) centers,
2 holes Ø 4.3 mm (0.17 in.) on 20 mm (0.79 in.) centers
3. 2 x Ø 3 holes for support studs, depth 4 mm (0.16 in.)
Dimensions
XCDR2•27••• XCDR2•18•••, XCDR2•19•••
1. Tapped entry for ISO M20 x 1.5 or PG 13.5 conduit thread or 1/2" NPT conduit.
2. 2 elongated holes Ø 4.3 x 6.3 mm (0.17 x 0.25 in.) on 22 mm (0.87 in.) centers, 2 holes Ø 4.3 mm (0.17 in.) on 20 mm (0.79 in.) centers.
3. 2 x Ø 3 holes for support studs, depth 4 mm (0.16 in.).
39,5
(1)
14
12,5
35,5
(2
)
(3
)
65
2
19
51
39,5
(1)
14
46
12,5
(2)
65
(3)
2
19
51
3,5
39,5
(1)
14
16
54,5
(2
)
20,2
5,5
12,5
65
(3
)
2
19
51
39,5
(1)
14
5,5
12
22
56,5
(2)
65
12,5
(3)
2
19
51
39,5
(1)
14
40
5,5 24
33
68
(2
)
(3)
2
19
51
19
78
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact with Manual Reset
Application, XCPR—Complete Switches, Plastic, with One Cable Entry, 1/2" NPT
Type of head Plunger (mounting by the body) Rotary (mounting by the body)
Type of operator Metal end
plunger Steel roller plunger
Thermoplastic
roller lever plunger,
horizontal actuation in
1direction
Thermoplastic roller
lever plunger, vertical
actuation in 1 direction
Thermoplastic roller
lever Steel roller lever
Catalog numbers of complete switches with one 1/2" NPT cable entry
2-pole N/C + N/O
snap action
(XE2SP2151)
XCPR2110N12 XCPR2102N12 XCPR2121N12 XCPR2127N12 XCPR2118N12 XCPR2119N12
2-pole N/C + N/O
break before make,
slow break
(XE2NP2151)
XCPR2510N12 XCPR2502N12 XCPR2521N12 XCPR2527N12 XCPR2518N12 XCPR2519N12
2-pole N/C + N/C
snap action
(XE2S P2141)
XCPR2910N12
XCPR2902N12
XCPR2921N12
XCPR2927N12
XCPR2918N12
—
Weight, kg (lb) 0.115 (0.254) 0.115 (0.254) 0.125 (0.276) 0.120 (0.265) 0.155 (0.342) —
Catalog numbers of complete switches with one PG 13.5 cable entry
For complete switches with one PG 13.5 cable entry, replace N12 with G13.
Example: XCPR 2110P20 becomes XCPR 2110G13.
Catalog numbers of complete switches with one P20 cable entry
For complete switches with one ISO M20 x 1.5 cable entry, replace N12 with P20.
Example: XCPR 2110N12 becomes XCPR 2110P20.
Contact operation contact closed
contact open
(A) (B) = cam displacement
(P) = positive opening point
N/C contact with positive opening
operation, when properly mounted and
using a conforming operator
Characteristics
Switch actuation On end By 30° cam
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1 m/s (3.28 ft/s) 1.5 m/s (4.92 ft/s)
Minimum force
or torque
For tripping 15 N (3.37 lb) 12 N (2.70 lb) 6 N (1.35 lb) 0.1 N•m (0.89 lb-in)
For positive opening 45 N (10.12 lb) 36 N (8.09 lb) 18 N (4.05 lb) 0.25 N•m (2.21 lb-in)
Cable entry
1 entry tapped M20 x 1.5 mm for ISO cable entry, clamping capacity 7 to 13 mm (0.28 to 0.51 in.), or
1 entry tapped PG 13.5, clamping capacity 9 to 12 mm (0.35 to 0.47 in.), or
1 entry tapped for 1/2" NPT (USAS B2-1) conduit
Other versions Complete switches with cable entries other than those listed above.
Consult your local sales office.
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P) 6,5(A)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14
6,5(B)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14
70
0
21-22
13-14
21-22
13-14
70
1314
22 21
1,8
0 5mm
3
3,2(P)
21-22
13-14
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14
6,5(A)
0mm
10,5
11,3(P)
21-22
13-14
6,5(B)
0mm
10,5
11,3(P
)
21-22
13-14
0
21-22
13-14
46
0
21-22
13-14
46
12 11
22 21
1,8
05mm
0,9
4,6(P)
11-12
21-22
11-12
21-22
3,1(A)
11-12
21-22
11-12
21-220mm
1,5
7,8(P) 6,5(A)
0mm
3
15,7(P)
11-12
21-22
11-12
21-22
6,5(B)
0mm
3
15,7(P)
11-12
21-22
11-12
21-22 0
11-12
21-22
11-12
21-22
70
79
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact with Manual Reset
Application, XCPR—Complete Switches, Plastic, with One Cable Entry, 1/2" NPT
Dimensions
XCPR2•10••• XCPR2•02••• XCPR2•21•••
1. Tapped entry for ISO M20 x 1.5 or PG 13.5 conduit thread
or 1/2" NPT conduit.
2. 2 elongated holes Ø 4.3 x 6.3 mm (0.17 x 0.25 in.)
on 22 mm (0.87 in.) centers,
2 holes Ø 4.3 mm (0.17 in.) on 20 mm (0.79 in.) centers.
3. 2 x Ø 3 holes for support studs, depth 4 mm (0.16 in.).
Dimensions
XCPR2•27••• XCPR2•18•••, XCPR2•19•••
1. Tapped entry for ISO M20 x 1.5 or PG 13.5 conduit thread or 1/2" NPT conduit.
2. 2 elongated holes Ø 4.3 x 6.3 mm (0.17 x 0.25 in.) on 22 mm (0.87 in.) centers, 2 holes Ø 4.3 mm (0.17 in.) on 20 mm (0.79 in.) centers.
3. 2 x Ø 3 holes for support studs, depth 4 mm (0.16 in.).
39,5
30
31
65
12,5
35,5
(1)
(2)
14
(3
)
2
19
51
39,5
(1)
14
46
12,5
(2)
(3)
2
19
51
3,5
(1)
39,5
14
16
5,5
12,5
54,5
20,2
(2)
(3)
2
19
51
5,5
12,5
20
56,5
(2)
39,5
(1)
14
(3)
2
19
51
39,5
(1)
14 65
30
40
5,5
24
33
68
(2)
(3)
2
19
51
19
80
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Compact with Manual Reset
Application, XCTR—Complete Switches, Plastic, with Two Cable Entries, 1/2" NPT
Type of head Plunger (mounting by the body)
Type of operator Metal end plunger Steel roller plunger Thermoplastic roller lever
plunger
Thermoplastic
roller lever plunger,
horizontal actuation in
1direction
Catalog numbers of complete switches with two cable entries, 1/2" NPT (1)
2-pole N/C + N/O
snap action
(XE2SP3151)
XCTR2110N12 XCTR2102N12 XCTR2118N12 XCTR2121N12
2-pole N/C + N/O
break before make,
slow break
(XE2NP3151)
XCTR2510N12 XCTR2502N12 XCTR2518N12 XCTR2521N12
Weight, kg (lb) 0.120 (0.265) 0.125 (0.276) 0.165 (0.364) 0.135 (0.298)
1. One PG 11 to 1/2" NPT adapter and one plug included.
Catalog numbers of complete switches with two PG 11 cable entries
For complete switches with two PG 11 cable entries, replace N12 with G11.
Example: XCTR 2110N12 becomes XCTR 2110G11.
Catalog numbers of complete switches with two ISO M16 x 1.5 cable entries
For complete switches with two ISO M16 x 1.5 cable entries, replace N12 with P16.
Example: XCTR 2110N12 becomes XCTR 2110P16.
Weight, kg (lb) 0.120 (0.265) 0.125 (0.276) 0.165 (0.364) 0.135 (0.298)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when
properly mounted and using a conforming operator
Characteristics
Switch actuation On end By 30° cam
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1.5 m/s (4.92 ft/s) 1 m/s (3.28 ft/s)
Minimum force or torque For tripping 15 N (3.37 lb) 12 N (2.70 lb) 0.1 N•m (0.89 lb-in) 6 N (1.35 lb)
For positive opening 45 N (10.12 lb) 36 N (8.09 lb) 0.25 N•m (2.21 lb-in) 18 N (4.05 lb)
Cable entry
(1 entry fitted with blanking plug)
2 entries tapped M16 x 1.5 mm for ISO cable entry, clamping capacity 4 to 8 mm (0.16 to 0.31 in.), or
2 entries tapped PG 11, clamping capacity 7 to 10 mm (0.28 to 0.39 in.), or
2 entries tapped for 1/2" NPT (USAS B2-1) conduit using PG 11 to 1/2" NPT adapter DE9RA1012
(1 entry fitted with adapter)
1314
22 21
1,8
05mm
0,9
4,6(P)
21-22
13-14
21-22
13-14
3,1(A)
21-22
13-14
21-22
13-140mm
1,5
7,8(P)
0
21-22
13-14
21-22
13-14
70
6,5(A)
0mm
3
15,7(P)
21-22
13-14
21-22
13-14
1314
22 21
1,8
0 5mm
3
3,2(P)
21-22
13-14
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14
0
21-22
13-14
46 6,5(A)
0mm
10,5
11,3(P)
21-22
13-14
81
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Compact, Metal with Manual Reset
Application, XCDR—Complete Switches with Two Cable Entries, 1/2" NPT
Dimensions
XCTR 2•18••• XCTR 2•21•••
1. Tapped entry for ISO M16 x 1.5 or PG 11 conduit thread. 1/2" NPT adapter included.
2. 4 elongated holes Ø 4.3 x 6.3 mm (0.17 x 0.25 in.) on 22/42 mm (0.87/1.65 in.) centers, 4 holes Ø 4.3 mm (0.17 in.) on 20/40 mm (0.79/1.57 in.) centers.
3. 2 x Ø 3 holes for support studs, depth 4 mm (0.16 in.).
XCTR 2•10••• XCTR 2•02••• DE9RA1012
1. Tapped entry for ISO M16 x 1.5 or PG 11 conduit thread. 1/2" NPT adapter included.
2. 4 elongated holes Ø 4.3 x 6.3 mm (0.17 x 0.25 in.) on 22/42 mm (0.87/1.65 in.) centers,
4 holes Ø 4.3 mm (0.17 in.) on 20/40 mm (0.79/1.57 in.) centers.
3. 2 x Ø 3 holes for support studs, depth 4 mm (0.16 in.).
4. Tapped entry for 1/2" NPT conduit.
5. PG 11 threaded sleeve.
20/22
40/42
58
==
12,5
(3)
40
37,6
39,5
40
5,5
24
33
68
2
51
(1)
(2)
19
20/22
40/42
58
==
12,5
(3)
40
37,6
39,5
30
16
54,5
2
51
(1)
(2)
12,5
5,5
20,2
40/42
58
==
39,5
30
12,5
35,5
2
51
(1
)
(2
)
(3)
40
37,6
20/22
40/42
58
==
12,5
39,5
3,5
46
2
12,5
51
30
(3)
(2)
(1)
40
37,6
21
(5)
(4)
Ø26
82
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKM, XCKL, and XCKML
b XCKM
with 3 cable entries
v With plunger head v With rotary or multi-directional head
Page 84
b XCKL
with 1 cable entry
v With plunger head v With rotary or multi-directional head
Page 86
b XCKML
with 3 cable entries and two 2-pole contacts
v With plunger head v With rotary or multi-directional head
Page 96
Environmental characteristics
Conforming to standards Products IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C22-2 n° 14
Machine assemblies IEC 60204-1, EN 60204-1
Product certifications UL, CSA, CCC (for XCKM)
Protective treatment Version Standard “TC”. Special “TH”
Ambient air temperature For operation - 25…+70 °C (-13…+158 °F)
For storage - 40…+70 °C (-40…+158 °F)
Vibration resistance Conforming to IEC 60068-2-6 25 gn (10…500 Hz)
Shock resistance Conforming to IEC 60068-2-27 50 gn (11 ms)
Electric shock protection Class I conforming to IEC 61140 and NF C 20-030
Degree of protection IP 66 conforming to IEC 60529; IK 05 conforming to EN 50102
Repeat accuracy XCKML 0.1 mm; XCKM and XCKL 0.05 mm on the tripping points, with 1 million operating cycles for head
with end plunger
Cable entry or
integral connector Depending on model
XCKM: 3 tapped entries, PG 11 conduit thread (1/2" NPT adapter available), or tapped M20
XCKL: 1 tapped entry incorporating 1/2" NPT adapter
XCKML: 3 tapped entries, PG 13 conduit thread (1/2" NPT adapter included), or tapped M20
Materials Bodies: Zamak® zinc alloy
Rotary heads: Zamak® zinc alloy or plastic depending on model; other heads: plastic
561643
561644
808148
561645
808140
808145
808141
808147
561639
561640
561641
561642
83
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKM, XCKL, and XCKML
Contact block characteristics
Rated operational
characteristics
XE2•P a AC-15; A300 (Ue = 240 V, Ie = 3 A); Ithe = 10 A
c DC-13; Q300 (Ue = 250 V, Ie = 0,27 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
XE3•P
a AC-15; B300 (Ue = 240 V, Ie = 1,5 A); Ithe = 6 A
c DC-13; R300 (Ue = 250 V, Ie = 0,1 A), conforming to IEC 60947-5-1 Appendix A,
EN 60947-5-1
Rated insulation voltage
XE2•P Ui = 500 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
XE3•P Ui = 400 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Rated impulse
withstand voltage
XE2•P U imp = 6 kV conforming to IEC 60947-1, IEC 60664
XE3•P U imp = 4 kV conforming to IEC 60947-1, IEC 60664
Positive operation (depending on model) N/C contacts with positive opening operation conforming to IEC 947-5-1 Section 3, EN 60 947-5-1
Resistance across terminals y 25 mΩ conforming to IEC 60255-7 category 3
Short-circuit protection XE2•P 10 A cartridge fuse type gG (gl)
XE3•P 6 A cartridge fuse type gG (gl)
Cabling
(screw and captive cable
clamp terminals)
XE2SP21•1 Clamping capacity, min: 1 x 0,34 mm
2
, max: 2 x 1,5 mm
2
XE2NP21•1 Clamping capacity, min: 1 x 0,5 mm
2
, max: 2 x 2,5 mm
2
XESP2151L and XENP2151L Clamping capacity, min: 1 x 0,34 mm
2
,
max: 2 x 1,5 mm
2
or 1 x 2,5 mm
2
XE3NP et XE3SP Clamping capacity, min: 1 x 0,34 mm
2
, max: 1 x 1 mm
2
or 2 x 0,75 mm
2
Minimum actuation speed XE2SP21•1, XESP2151L and XE3SP: 0.01 m/minute (0.03 ft/minute)
XE2NP21•1, XENP2151L and XE3NP: 6 m/minute (19.68 ft/minute)
Electrical durability
•Conforming to IEC 60947-5-1 appendix C
•Utilization categories AC-15 and DC-13
•Maximum operating rate: 3600 operating cycles/hour
•Load factor: 0,5
XE2SP21•1, XE2SP2141, XESP2151L XE2NP21•1, XENP2151L
a.c. supply
a 50/60 Hz
o inductive circuit
d.c. supply c
Power switched in W for 5 million operating
cycles
Power switched in W for 5 million operating
cycles
Voltage V 24 48 120 Voltage V 24 48 120
oW10 7 4 oW13 9 7
For XE2SP•151 on a or c, the “N/C” and “N/O” contacts are simultaneously loaded to the values shown with reverse
polarity.
XE3SP•••• XE3NP••••
a.c. supply
a 50/60 Hz
o inductive circuit
d.c. supply c
Power switched in W for 5 million operating
cycles
Power switched in W for 5 million operating
cycles
Voltage V 24 48 120 Voltage V 24 48 120
oW321 oW432
Millions o
f
operating cycles
Current in A
0,1
0,5
1
5
0,5 1 5 10
110 V
48 V
230/400 V
234
Ithe
24 V
Millions of operating cycless
Current 1n A
0,5 1 2 3 4 5 10
0,1
0,2
0,5
1
5
2
4
3
Ithe
230 V
12/24/48 V
110 V
0,1
0,5
1
5
0,5 1 5 10
110 V
48 V
230/400 V
234
Ithe
24 V
Millions o
f
operating cycles
Current in A
Millions of operating cycles
Current in A
0,5 1 2 3 4 5 10
0,1
0,2
0,5
1
5
2
4
3
Ithe
230 V
110 V
12/24/48 V
84
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKM—Complete Switches w/ 3 ISO M20x1.5 Cable Entries, Including One 1/2" NPT Adapter
Type of head Plunger (mounting by the body) Rotary (mounting by
the body)
Multi-directional
(mounting by the
body)
Type of operator Metal end plunger Steel roller plunger
Thermoplastic roller lever
plunger, horizontal
actuation in 1 direction
Thermoplastic roller lever
(1) Cat’s whisker (4)
Catalog numbers (
2)
(3)
2-pole N/C + N/O
snap action
(XE2SP2151)
XCKM110H29 XCKM102H29 XCKM121H29 XCKM115H29 XCKM106H29
2-pole N/C + N/O
break before make,
slow break
(XE2NP2151)
XCKM510H29 XCKM502H29 XCKM521H29 XCKM515H29 XCKM506H29
2-pole N/C + N/C
snap action
(XE2SP2141)
ZCKM9H29 +
ZCKD10
ZCKM9H29 +
ZCKD02
ZCKM9H29 +
ZCKD21
ZCKM9H29 +
ZCKD15
ZCKM9H29 +
ZCKD06
2-pole N/C + N/C
simultaneous,
slow break
(XE2NP2141)
ZCKM7H29 +
ZCKD10
ZCKM7H29 +
ZCKD02
ZCKM7H29 +
ZCKD21
ZCKM7H29 +
ZCKD15
ZCKM7H29 +
ZCKD06
3-pole
N/C + N/C + N/O
snap action
(XE3SP2141)
ZCKMD39H29 +
ZCKD10
ZCKMD39H29 +
ZCKD02
ZCKMD39H29 +
ZCKD21
ZCKMD39H29 +
ZCKD15
ZCKMD39H29 +
ZCKD06
3-pole
N/C + N/C + N/O
break before make,
slow break
(XE3NP2141)
ZCKMD37H29 +
ZCKD10
ZCKMD37H29 +
ZCKD02
ZCKMD37H29 +
ZCKD21
ZCKMD37H29 +
ZCKD15
ZCKMD37H29 +
ZCKD06
Weight, kg (lb) 0.250 (0.551) 0.255 (0.562) 0.300 (0.661) 0.280 (0.617) 0.250 (0.551)
Contact operation contact closed (A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when
properly mounted and using a conforming operator
contact open
Characteristics
Switch actuation On end By 30° cam By any moving part
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1.5 m/s (4.92 ft/s) 1 m/s (3.28 ft/s),
any direction
Minimum force
or torque
For tripping 15 N (3.37 lb) 12 N (2.70 lb) 8 N (1.80 lb) 0.1 N•m (0.89 lb-in) 0.13 N•m (1.15 lb-in)
For positive opening 45 N (10.12 lb) 36 N (8.09 lb) 24 N (5.40 lb) 0.25 N•m (2.21 lb-in) —
Cable entry (3) 3 entries tapped M20 x 1.5 mm for ISO cable entry, clamping capacity 7 to 13 mm (0.28 to 0.51 in.)
1. Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.
2. Switches with gold contacts or eyelet type connections: please consult your local sales office.
3. For an entry tapped for a PG 11 conduit thread, delete H29 from the end of the catalog number. Example: XCKM110H29 becomes XCKM110.
4. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mounting.
Note: To convert XCKM110 from PG 11 to 1/2" NPT, use adapter DE9RA1012, included.
1314
22 21
1,8
05,5mm
0,9
4,5(P)
21-22
13-14
21-22
13-14
3,1(A)
0mm
1,5
7,8(P)
21-22
13-14
21-22
13-14
4,6(A)
0mm
2,2
11,1(P)
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14
1314
22 21
1,8
0 5,5mm3
3,2(P)
21-22
13-14
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14
4,6(A)
07,6 mm
8(P)
21-22
13-14 0
21-22
13-14
0
21-22
13-14
12 11
22 21
1,8
05,5mm
0,9
4,5(P)
11-12
21-22
11-12
21-22
3,1(A)
0mm
1,5
7,8(P)
11-12
21-22
11-12
21-22
4,6(A)
0mm
2,2
11,1(P)
11-12
21-22
11-12
21-22 0
11-12
21-22
11-12
21-22 0
11-12
21-22
11-12
21-22
12 11
22 21
3,2(P)
5,5mm
1,8
11-12
21-22 9mm
3,1(A)
5,6(P)
11-12
21-22
4,6(A)
8(P)
11-12
21-22
mm
11-12
21-22 11-12
21-22
22 21
32 31
14 13
13-14
21-22
31-32
13-14
31-32
21-22
5,5
0,9
1,8 4,5 (P) mm
13-14
21-22
31-32
13-14
31-32
21-22
1,5
3,1 (A) 7,8 (P) mm
13-14
21-22
31-32
13-14
31-32
21-22
2,2
4,6 (A) 11,1 (P)mm
13-14
21-22
31-32
13-14
31-32
21-22
70˚
0
11˚
26˚ 58˚ (P)
13-14
21-22
31-32
13-14
31-32
21-22
14˚
30˚
22 21
32 31
14 13
13-14
31-32
3
1,8 mm
0 5,5
3,2 (P)
21-22
13-14
31-32
5,2
3,1 (A) mm
0 5,5
3,2 (P)
21-22
13-14
31-32
0 7,6
4,6 (A) mm8 (P)
21-22
13-14
31-32
0 36˚
26˚
70˚
42˚ (P)
21-22
13-14
31-32
040˚
30˚
21-22
85
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKM—Complete Switches w/ 3 ISO M20x1.5 Cable Entries, Including One 1/2" NPT Adapter
XCKM•10
ZCKMD3• + ZCKD10
XCKM•02
ZCKMD3• + ZCKD02
XCKM•21
ZCKMD3• + ZCKD21
XCKM•15
ZCKMD3• + ZCKD15
XCKM•06
ZCKMD3• + ZCKD06
Rear view
XCKM•••, ZCKM•, ZCKMD3•
1. 3 tapped entries for ISO M20 x 1.5 or PG 11 conduit thread. Includes 1/2" NPT conduit adapter DE9RA1012.
2. 2 x Ø 4 H 11, depth 10.
Ø: 2 elongated holes Ø 5.2 x 6.2.
Adapter for 1/2" NPT conduit
DE9RA1012
1. Tapped entry for 1/2" NPT conduit.
2. PG 11 threaded sleeve.
41
64
30
==
88,5
30
14
(1)
48,5
41
64
==
4
14
108
30
(1)
8
14
112,5
30
(1)
54
41
65
11,5
34,5
60,5
41
64
==
5,5
22 15
119
30
34
(1)
8
14
201
30
(1)
142,5
41
64
==
41
=27 =
54
(2)
21
(2)
(1)
86
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKL—Complete Switches Incorporating Adapter for 1/2" NPT
Type of head Plunger (mounting by the body) Rotary (mounting
by the body)
Multi-directional
(mounting by the
body)
Type of operator Metal end plunger Steel roller plunger
Thermoplastic roller lever
plunger,
horizontal actuation in 1
direction
Thermoplastic roller lever
(1) Cat’s whisker (2)
Catalog numbers (
3)
2-pole N/C + N/O
snap action
(XE2SP2151)
XCKL110 XCKL102 XCKL121 XCKL115 XCKL106
2-pole N/C + N/O
break before make,
slow break
(XE2NP2151)
XCKL510 XCKL502 XCKL521 XCKL515 XCKL506
3-pole
N/C + N/C + N/O
snap action
(XE3SP2141)
ZCKLD39 +
ZCKD10
ZCKLD39 +
ZCKD02
ZCKLD39 +
ZCKD21
ZCKLD39 +
ZCKD15
ZCKLD39 +
ZCKD06
2-pole N/C + N/C
simultaneous,
slow break
(XE2NP2141)
ZCKL7 + ZCKD10 ZCKL7 + ZCKD02 ZCKL7 + ZCKD21 ZCKL7+ ZCKD15 ZCKL7 + ZCKD06
3-pole
N/C + N/C + N/O
break before make,
slow break
(XE3NP2141)
ZCKLD37 +
ZCKD10
ZCKLD37 +
ZCKD02
ZCKLD37 +
ZCKD21
ZCKLD37 +
ZCKD15
ZCKLD37 +
ZCKD06
Weight, kg (lb) 0.255 (0.562) 0.260 (0.573) 0.305 (0.672) 0.285 (0.628) 0.255 (0.562)
Contact operation contact closed (A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when
properly mounted and using a conforming operator
contact open
Characteristics
Switch actuation On end By 30° cam By any moving part
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1.5 m/s (4.92 ft/s) 1 m/s (3.28 ft/s),
any direction
Minimum force
or torque
For tripping 15 N (3.37 lb) 12 N (2.70 lb) 8 N (1.80 lb) 0.1 N•m (0.89 lb-in) 0.13 N•m (1.15 lb-in)
For positive opening 45 N (10.12 lb) 36 N (8.09 lb) 24 N (5.40 lb) 0.25 N•m (2.21 lb-in) —
Cable entry 1 entry incorporating metal cable entry. Clamping capacity 6 to 13.5 mm (0.24 to 0.53 in.).
1. Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.
2. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mounting.
3. Switches with gold contacts or eyelet type connections: please consult your local sales office.
1314
22 21
1,8
05,5mm
0,9
4,5(P)
21-22
13-14
21-22
13-14
3,1(A)
0mm
1,5
7,8(P)
21-22
13-14
21-22
13-14
4,6(A)
0mm
2,2
11,1(P)
21-22
13-14
21-22
13-14
0
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14
1314
22 21
1,8
0 5,5mm3
3,2(P)
21-22
13-14
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14
4,6(A)
07,6 mm
8(P)
21-22
13-14
0
21-22
13-14
0
21-22
13-14
22 21
32 31
14 13
13-14
21-22
31-32
13-14
31-32
21-22
5,5
0,9
1,8 4,5 (P) mm
13-14
21-22
31-32
13-14
31-32
21-22
1,5
3,1 (A) 7,8 (P) mm
13-14
21-22
31-32
13-14
31-32
21-22
2,2
4,6 (A) 11,1 (P)mm
13-14
21-22
31-32
13-14
31-32
21-22
70˚
0
11˚
26˚ 58˚ (P)
13-14
21-22
31-32
13-14
31-32
21-22
14˚
30˚
12 11
22 21
3,2(P)
5,5mm
1,8
11-12
21-22 9mm
3,1(A)
5,6(P)
11-12
21-22 4,6(A)
8(P)
11-12
21-22
mm
11-12
21-22 11-12
21-22
22 21
32 31
14 13
13-14
31-32
3
1,8 mm
0 5,5
3,2 (P)
21-22
13-14
31-32
5,2
3,1 (A) mm
0 5,5
3,2 (P)
21-22
13-14
31-32
0 7,6
4,6 (A) mm8 (P)
21-22
13-14
31-32
0 36˚
26˚
70˚
42˚ (P)
21-22
13-14
31-32
0 40˚
30˚
21-22
87
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKL—Complete Switches Incorporating Adapter for 1/2" NPT
XCKL•10
ZCKL• + ZCKD10
ZCKLD3• + ZCKD10
XCKL•02
ZCKL3• + ZCKD02
ZCKLD3• + ZCKD02
XCKL•21
ZCKL• + ZCKD21
ZCKLD3• + ZCKD21
XCKL•15
ZCKL• + ZCKD15
ZCKLD3• + ZCKD15
XCKL•06
ZCKL• + ZCKD06
ZCKLD3• + ZCKD06
Body mountings
1. Incorporated cable entry.
Ø: 2 elongated holes Ø 5.2 x 6.2.
30
41
52
==
14
(1)
97
30
48,5
41
52
==
4
14
(1)
115,5
30
54
41
59,5
5,5
8
14
121
30 (1)
6
22 15
127,5
30
34
(1)
8
41
52
==
34,5
60,5
14
(1)
209,5
30
142,5
41
52
==
41
67
52
==
(1)
72
30
6
88
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKM and XCKL—Modular
1. For further details. See page 90.
2. For 3 cable entries tapped ISO M20 x 1.5, add H29 to the catalog number. Example: ZCKM1 becomes ZCKM1H29.
ZCK D029ZCK D10 ZCK D109
ZCK D08ZCK D06
ZCK M1, M5, M6, M7, M9
ZCK M8
ZCK D02
ZCK D16 ZCK D17ZCK D15
ZCK D219 ZCK D23ZCK D21 ZCK D239
ZCK D41ZCK D81 ZCK D91 ZCK D59
ZCK MD3
ZCK L1, L5, L6, L7
ZCK LD3
ZCK L8
Cat’s whisker
Round rod lever,
thermoplastic, Ø 6 (0.24)
L = 200 (7.87) (5)
Spring lever with
thermoplastic end
(4)
Spring-rod lever,
metal (4)
Variable length
thermoplastic roller
lever (4)
Spring rod
Thermoplastic
roller lever (4)
Steel ball bearing
mounted roller lever (4)
Steel
roller lever (4)
Thermoplastic
roller lever
plunger
1 direction of
actuation
Thermoplastic
roller lever
plunger with
protective boot,
1 direction
of actuation
Metal end plunger Steel roller plunger
Metal end plunger
with protective boot Steel roller plunger
with protective boot
Body with 2-pole contact,
3 cable entries for PG 11 (1) (2)
Body with 2-pole contact,
with incorporated cable entry (1)
Body with 3-pole contact,
3 cable entries for PG 11 (1) (2)
Body with 3-pole contact,
with incorporated cable entry (1)
Steel
roller lever plunger
with protective boot
1 direction of actuation
Steel
roller lever
plunger
1 direction of
actuation
Dimensions: mm (in.)
89
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKM and XCKL—Modular
: head assuring positive opening operation, when properly mounted and using a conforming operator.
3. Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.
4. Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting.
ZCK D05
ZCK Y33 ZCK Y34ZCK Y31
ZCK Y41 ZCK Y43
ZCK Y81ZCK Y91
ZCK Y55 ZCK Y59ZCK Y54
ZCK Y49 ZCK Y39
ZCK G00
Square rod lever,
steel, U 3 (0.12)
L = 125 (4.92) (4)
Round rod lever,
thermoplastic, Ø 6 (0.24)
L = 200 (7.87) (4)
Round rod lever,
glass fibre Ø 3
(0.12)
L = 125 (4.92) (4)
Spring lever with
thermoplastic end
(3)
Spring-rod lever,
metal (3)
Variable length
thermoplastic
roller lever (3)
Variable
length
steel
roller
lever (3)
Variable
length
elastomer
roller lever,
Ø 50 (1.97) (3)
Elastomer
roller lever,
Ø 50 (1.97) (3)
Thermoplastic
roller lever
(3)
Steel
roller lever
(3)
Steel ball bearing
mounted roller lever
(3)
For actuation
from left AND right
or
from left OR right
Dimensions: mm (in.)
90
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKM and XCKL—Modular
Bodies with 2-pole contact
With contact block Function diagram Positive
operation (1) Cable entry Catalog number Weight
kg (lb)
For limit switches type XCKM
N/C + N/O
snap action
(XE2S P2151)
1/2" NPT (2) ZCKM1 0.210 (0.463)
ISO M20 x 1.5 ZCKM1H29 0.210 (0.463)
N/C + N/O
break before make,
slow break
(XE2N P2151)
1/2" NPT (2) ZCKM5 0.210 (0.463)
ISO M20 x 1.5 ZCKM5H29 0.210 (0.463)
N/O + N/C
make before make,
slow break
(XE2N P2161)
1/2" NPT (2) ZCKM6 0.210 (0.463)
ISO M20 x 1.5 ZCKM6H29 0.210 (0.463)
N/C + N/C
simultaneous,
slow break
(XE2N P2141)
1/2" NPT (2) ZCKM7 0.210 (0.463)
ISO M20 x 1.5 ZCKM7H29 0.210 (0.463)
N/O + N/O
simultaneous,
slow break
(XE2N P2131)
—
1/2" NPT (2) ZCKM8 0.210 (0.463)
ISO M20 x 1.5 ZCKM8H29 0.210 (0.463)
N/C + N/C
snap action
(XE2S P2141)
ISO M20 x 1.5 ZCKM9H29 0.210 (0.463)
For limit switches type XCK L
N/C + N/O
snap action
(XE2S P2151)
1/2" NPT ZCKL1 0.210 (0.463)
N/C + N/O
break before make,
slow break
(XE2N P2151)
1/2" NPT ZCKL5 0.210 (0.463)
N/O + N/C
make before make,
slow break
(XE2N P2161)
1/2" NPT ZCKL6 0.210 (0.463)
N/C + N/C
simultaneous,
slow break
(XE2N P2141)
1/2" NPT ZCKL7 0.210 (0.463)
N/O + N/O
simultaneous,
slow break
(XE2N P2131)
—1/2" NPTZCKL8 0.210 (0.463)
1. : N/C contact with positive opening operation, when properly mounted and using a conforming operator.
2. 3 PG 11 tapped entries, one with metal adapter for 1/2" NPT (USASB2-1) conduit (PG 8).
22 21
13
14
22 21
13
14
22 21
14 13
12 11
22 21
1314
24 23
12 11
22 21
22 21
13
14
22 21
13
14
22 21
14 13
12 11
22 21
1314
24 23
91
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKM and XCKL—Modular
Bodies with 3-pole contact
With contact block Function diagram Positive
operation (1) Cable entry Catalog number Weight
kg (lb)
For limit switches type XCKM
N/C + N/O + N/O
snap action
(XE3S P2151)
1/2" NPT (2) ZCKMD31 0.210 (0.463)
ISO M20 x 1.5 ZCKMD31H29 0.210 (0.463)
N/C + N/C + N/O
snap action
(XE3S P2141)
1/2" NPT (2) ZCKMD39 0.210 (0.463)
ISO M20 x 1.5 ZCKMD39H29 0.210 (0.463)
N/C + N/C + N/O
break before make,
slow break
(XE3N P2141)
1/2" NPT (2) ZCKMD37 0.210 (0.463)
ISO M20 x 1.5 ZCKMD37H29 0.210 (0.463)
N/C + N/O + N/O
break before make,
slow break
(XE3N P2151)
1/2" NPT (2) ZCKMD35 0.210 (0.463)
ISO M20 x 1.5 ZCKMD35H29 0.210 (0.463)
For limit switches type XCK L
N/C + N/O + N/O
snap action
(XE3S P2151)
1/2" NPT ZCKLD31 0.210 (0.463)
N/C + N/C + N/O
snap action
(XE3S P2141)
1/2" NPT ZCKLD39 0.210 (0.463)
N/C + N/C + N/O
break before make,
slow break
(XE3N P2141)
1/2" NPT ZCKLD37 0.210 (0.463)
N/C + N/O + N/O
break before make,
slow break
(XE3N P2151)
1/2" NPT ZCKLD35 0.210 (0.463)
1. : N/C contact with positive opening operation, when properly mounted and using a conforming operator.
2. 3 PG 11 tapped entries, one with metal adapter for 1/2" NPT (USASB2-1) conduit (PG 8).
32 31
1314
3334
32 31
22 21
1314
32 31
22 21
1314
22 21
1314
3334
32 31
1314
3334
32 31
22 21
1314
32 31
22 21
1314
22 21
1314
3334
92
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKM and XCKL—Modular
Contact blocks
Type of contact Function diagram For bodies Positive
operation (1) Catalog number Weight
kg (lb)
2-pole contact
N/C + N/O
snap action
ZCKM1
ZCKL1 XE2SP2151 0.020 (0.044)
N/C + N/O
break before make,
slow break
ZCKM5
ZCKL5 XE2NP2151 0.020 (0.044)
N/O + N/C
make before break,
slow break
ZCKM6
ZCKL6 XE2NP2161 0.020 (0.044)
N/C + N/C
simultaneous,
slow break
ZCKM7
ZCKL7 XE2NP2141 0.020 (0.044)
N/O + N/O
simultaneous,
slow break
ZCKM8
ZCKL8 —XE2NP2131 0.020 (0.044)
N/C + N/C
snap action ZCKM9 XE2SP2141 0.020 (0.044)
3-pole contact
N/C + N/O + N/O
snap action
ZCKMD31
ZCKLD31 XE3SP2151 0.035 (0.077)
N/C + N/C + N/O
snap action
ZCKMD39
ZCKLD39 XE3SP2141 0.035 (0.077)
N/C + N/C + N/O
break before make,
slow break
ZCKMD37
ZCKLD37 XE3NP2141 0.035 (0.077)
N/C + N/O + N/O
break before make,
slow break
ZCKMD35
ZCKLD35 XE3NP2151 0.035 (0.077)
1. : N/C contact with positive opening operation or sub-assembly assuring positive opening operation when properly mounted and using a
conforming operator.
Accessories for limit switches type XCKM
Description Sold in
lots of
Unit catalog
number
Weight
kg (lb)
Tap-off terminal
for cabling continuity 1XCKZ09 0.010 (0.022)
Clip-in markers
(strips of 10 numbers: 0 to 9)
Other markers, please consult your local sales office.
25 AB1R11 0.002 (0.004)
Other versions Gold flashed contacts.
Please consult your local sales office.
22 21
13
14
22 21
13
14
22 21
14 13
12 11
22 21
1314
24 23
12 11
22 21
32 31
1314
3334
32 31
22 21
1314
32 31
22 21
1314
22 21
1314
3334
0987654321
93
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKM and XCKL—Modular
Heads ZCKD10, D109 with
body
ZCKM1, L1 ZCKM5, L5 ZCKM6, L6 ZCKM7, L7 ZCKM8, L8
ZCKM9 ZCKMD39, LD39 ZCKMD37, LD37 ZCKMD31, LD31 ZCKMD35, LD35
Heads ZCKD02, D029 with
body
ZCKM1, L1 ZCKM5, L5 ZCKM6, L6 ZCKM7, L7 ZCKM8, L8
ZCKM9 ZCKMD39, LD39 ZCKMD37, LD37 ZCKMD31, LD31 ZCKMD35, LD35
Heads ZCKD21, D23, D219,
D239 with body
ZCKM1, L1 ZCKM5, L5 ZCKM6, L6 ZCKM7, L7 ZCKM8, L8
ZCKM9 ZCKMD39, LD39 ZCKMD37, LD37 ZCKMD31, LD31 ZCKMD35, LD35
Heads ZCKD15, D16, D17
with body
ZCKM1, L1 ZCKM5, L5 ZCKM6, L6 ZCKM7, L7 ZCKM8, L8
ZCKM9 ZCKMD39, LD39 ZCKMD37, LD37 ZCKMD31, LD31 ZCKMD35, LD35
Heads ZCKD41, D59, D81,
D91 with body
ZCKM1, L1 ZCKM5, L5 ZCKM6, L6 ZCKM7, L7 ZCKM8, L8
ZCKM9 ZCKMD39, LD39 ZCKMD37, LD37 ZCKMD31, LD31 ZCKMD35, LD35
Heads ZCKD06, D08 with
body
ZCKM1, L1 ZCKM5, L5 ZCKM6, L6 ZCKM7, L7 ZCKM8, L8
ZCKM9 ZCKMD39, LD39 ZCKMD37, LD37 ZCKMD31, LD31 ZCKMD35, LD35
Contact operation G contact closed
H contact open
(A) = cam displacement
(P) = positive opening point
1,8
05,5mm
0,9
4,5(P)
21-22
13-14
21-22
13-14
1,8
0 5,5mm3
3,2(P)
21-22
13-14
3
5,5mm
1,8
4,4(P)
21-22
13-14
3,2(P)
5,5mm
1,8
11-12
21-22
5,5mm
1,8
13-14
23-24
1,8
05,5mm
0,9
4,5(P)
11-12
21-22
11-12
21-22
1,8 4,5(P)
5,5mm
13-14
31-32
21-22
21-22
31-32
13-14
00,9
3,2(P)
5,5mm3
1,8
21-22
31-32
13-14
0
1,8 4,5(P)
5,5mm
13-14
33-34
21-22
21-22
33-34
13-1400,9
3,2(P)
5,5mm3
1,8
21-22
33-34
13-14
0
3,1(A)
0mm
1,5
7,8(P)
21-22
13-14
21-22
13-14
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14
9mm
3,1
5,2(A) 7,6(P)
21-22
13-14
9mm
3,1(A)
5,6(P)
11-12
21-22
9mm
3,1(A)
13-14
23-24
3,1(A)
0mm
1,5
7,8(P)
11-12
21-22
11-12
21-22
3,1(A) 7,8(P)
mm
13-14
31-32
21-22
21-22
31-32
13-14
01,5
5,6(P)
mm5,2
3,1(A)
21-22
31-32
13-14
0
3,1(A) 7,8(P)
mm
13-14
33-34
21-22
21-22
33-34
13-1401,5
5,6(P)
mm5,2
3,1(A)
21-22
33-34
13-14
0
4,6(A)
0mm
2,2
11,1(P)
21-22
13-14
21-22
13-14
4,6(A)
07,6 mm
8(P)
21-22
13-14
4,6(A)
21-22
13-14
7,6 11,1(P)
mm 4,6(A)
8(P)
11-12
21-22
mm 4,6(A)
13-14
23-24
mm
4,6(A)
0mm
2,2
11,1(P)
11-12
21-22
11-12
21-22
4,6(A) 11,1(P)
mm
13-14
31-32
21-22
21-22
31-32
13-14
2,2
0
mm7,6
0
8(P)
4,6(A)
21-22
31-32
13-14
4,6(A) 11,1(P)
mm
13-14
33-34
21-22
21-22
33-34
13-14
02,2
0
8(P)
mm7,6
4,6(A)
21-22
33-34
13-14
26
070
11
58
21-22
13-14
21-22
13-14
(P) 21-22
13-14
(P)
26
036 70
42
24 70
21-22
13-14
40 60 (P)
24 70
11-12
21-22
43 (P)
24 70
13-14
23-24
26
070
11
58
11-12
21-22
11-12
21-22
(P) 58˚(P)
26˚
70˚
13-14
31-32
21-22
21-22
31-32
13-14
011˚
070˚36˚
26˚ 42˚(P)
21-22
31-32
13-14
26˚ 58˚(P)
13-14
33-34
21-22
21-22
33-34
13-14
011˚ 70˚
0
42˚(P)
70˚36˚
26˚
21-22
33-34
13-14
26
070
11
21-22
13-14
21-22
13-14
21-22
13-14
26
036 70 24 70
21-22
13-14
40
24 70
11-12
21-22
24 70
13-14
23-24
26
070
11
11-12
21-22
11-12
21-22
26˚
70˚
13-14
31-32
21-22
21-22
31-32
13-14
0
11˚
070˚36˚
26˚
21-22
31-32
13-14
70˚
13-14
33-34
21-22
21-22
33-34
13-14
011˚
26˚
070˚36˚
26˚
21-22
33-34
13-14
21-22
13-14
21-22
13-14
30
0
14
30
040
21-22
13-14
30
21-22
13-14
40
30
11-12
21-22
30
13-14
23-24
11-12
21-22
11-12
21-22
30
0
14
30˚
13-14
31-32
21-22
21-22
31-32
13-14
014˚
040˚
30˚
21-22
31-32
13-14
30˚
13-14
33-34
21-22
21-22
33-34
13-14
0
14˚
040˚
30˚
21-22
33-34
13-14
94
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKM and XCKL—Modular
Complete Switches
NOTE: Some combinations are not available. Use this information to interpret catalog numbers, not to create them.
Bodies with contacts
ZCKM1, M5, M6, M7, M8,
ZCKM1H29, M5H29, M6H29, M7H29, M8H29, M9H29 ZCKL1, L5, L6, L7, L8, LD3• (5)
Adapter for 1/2" NPT conduit
DE9RA1012
1. 3 tapped entries for ISO M20 x 1.5 or PG 11 conduit thread.
2. Incorporated cable entry.
Ø: 2 elongated holes Ø 5.2 x 6.2.
3. Tapped entry for 1/2" NPT conduit.
4. Threaded sleeve, PG 11.
5. XCKL provided with 1/2" NPT adapter shown above, DE9RA1012.
63,6
30
6
(1)
41
64
58,5
==
41
67
52
==
(2)
72
30
6
21
(4)
(3)
Ø26
For interpretating the complete switch catalog number only
XCK L
X—complete
Z—component
Switch type
1 SPDT N.O., N.C. snap
5 SPDT N.O., N.C. slow
Head type
00—rotary programmable
02—roller plunger
06—wobble stick
10—steel plunger
21—one way
15—rotary
Levers (for rotary head 00 only)
11—Delrin® roller
41—adjustable delvin roller
Direct opening contacts
meet IEC 60947-5-1
requirements.
95
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKM and XCKL—Modular
Plunger heads
ZCKD10 ZCKD109 ZCKD02
ZCKD029 ZCKD21, D23 ZCKD219, D239
Rotary heads
ZCKD15, D16, D17 ZCKD41 ZCKD59
ZCKD81 ZCKD91 ZCKG00
Multi-directional heads
ZCKD06 ZCKD08
1. 190 max.
2. 215.5 max.
NOTE: operating lever spindle threaded M6.
14
30
30
14 4
14
48,5
48
4
14
8
14
54
13 8
14
54
13
5,5
37
15
34
34,5
60,5
6 43
51
56
29,5...84
50 ...104,5
55
44,5 31,7
(1)
(2)
51
56
112
179
51
56
6 43
51
56
29,5...84
50 ...104,5
14
142,5
129,5
14
96
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKML, 2 x 2-Pole Contacts—Complete Switches
Type of head Plunger (mounting by the body) Rotary
(mounting by the body)
Type of operator Metal end plunger Steel roller plunger
Thermoplastic roller lever plunger,
horizontal actuation
in 1 direction
Thermoplastic roller lever (1)
Catalog numbers (
2)
Switches with 3 entries tapped ISO M20 x 1.5
2 x 2-pole N/C + N/O
snap action (XESP2151L)
XCKML110H29 XCKML102H29 XCKML121H29 XCKML115H29
2 x 2-pole N/C + N/O
break before make, slow break
(XENP2151L)
XCKML510H29 XCKML502H29 XCKML521H29 XCKML515H29
Switches with 3 entries tapped for PG 13 conduit thread, plus adapter for 1/2" NPT
2 x 2-pole N/C + N/O
snap action (XESP2151L)
XCKML110 XCKML102 XCKML121 XCKML115
2 x 2-pole N/C + N/O
break before make, slow break
(XENP2151L)
XCKML510 XCKML502 XCKML521 XCKML515
Weight, kg (lb) 0.400 (0.882) 0.405 (0.893) 0.450 (0.992) 0.430 (0.948)
Contact operation contact closed (A) = cam displacement N/C contact with positive opening operation, when properly mounted
and using a conforming operator
contact open (P) = positive opening point
Characteristics
Switch actuation On end By 30° cam
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1.5 m/s (4.92 ft/s)
Minimum
force
For tripping 15 N (3.37 lb) 12 N (2.70 lb) 8 N (1.80 lb) 0.2 N•m (1.77 lb-in)
For positive
opening 60 N (13.49 lb) 50 N (11.24 lb) 50 N (11.24 lb) 0.5 N•m (4.43 lb-in)
Cable entry
3 entries tapped ISO M20 x 1.5, clamping capacity 7 to 13 mm (0.28 to 0.51 in.); or
3 entries tapped for PG 13 conduit thread conforming to NF C 68-300 (DIN PG 13.5),
clamping capacity 9 to 12 mm (0.35 to 0.47 in.) (0.35 to 0.47 in.), plus adapter for 1/2" NPT
1. Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.
2. Switches available with other 2-pole slow break contact blocks: N/O + N/C make before break, N/C + N/C simultaneous (with positive opening operation, when properly mounted and
using a conforming operator), N/C + N/C simultaneous, please consult your local sales office.
Replacement parts
The heads of limit switches type XCKML are the same as those for types XCKM and XCKL
(see heads ZCKD10, ZCKD02, ZCKD21 and ZCKD15 on page 88).
1314
22 21
A
1314
22 21
B
25(P)
21-22
13-14
21-22
13-14
06mm
1,2
21-22
13-14
21-22
13-14
A
B
4(A) 9(P)
21-22
13-14
21-22
13-14
0mm
A
B
2
21-22
13-14
21-22
13-14
5(A) 12,6(P)
21-22
13-14
21-22
13-14
0mm
3
21-22
13-14
21-22
13-14
A
B
21-22
13-14
21-22
13-14
0
21-22
13-14
21-22
13-14
A
B
1314
22 21
A
1314
22 21
B
23,4(P)
21-22
13-14
0 6,6mm3,3
21-22
13-14
A
B
3,3(A) 6(P)
21-22
13-14
0mm
6
21-22
13-14
A
B
6(A) 9,3(P)
21-22
13-14
010 mm
21-22
13-14
A
B
21-22
13-14
0
21-22
13-14
A
B
1314
22 21
A
1314
22 21
B
25(P)
21-22
13-14
21-22
13-14
06mm
1,2
21-22
13-14
21-22
13-14
A
B
4(A) 9(P)
21-22
13-14
21-22
13-14
0mm
A
B
2
21-22
13-14
21-22
13-14
5(A) 12,6(P)
21-22
13-14
21-22
13-14
0mm
3
21-22
13-14
21-22
13-14
A
B
21-22
13-14
21-22
13-14
0
21-22
13-14
21-22
13-14
A
B
1314
22 21
A
1314
22 21
B
23,4(P)
21-22
13-14
0 6,6mm3,3
21-22
13-14
A
B
3,3(A) 6(P)
21-22
13-14
0mm
6
21-22
13-14
A
B
6(A) 9,3(P)
21-22
13-14
010 mm
21-22
13-14
A
B
21-22
13-14
0
21-22
13-14
A
B
97
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal
XCKML, 2 x 2-Pole Contacts—Complete Switches
XCKML110H29, XCKML510H29, XCKML110, XCKML510 XCKML102H29, XCKML502H29, XCKML102, XCKML502
XCKML121H29, XCKML521H29, XCKML121, XCKML521 XCKML115H29, XCKML515H29, XCKML115, XCKML515
1. XCKML•••H29: 3 entries tapped M20 x 1.5. XCKML•••: 3 entries tapped for PG 13 conduit thread (adapter DE9RA1212 for 1/2" NPT available).
2. 2 centering holes Ø 3.9 ± 0.2, cover mounting holes axis.
Ø: 2 elongated holes 6.2 x 6.5, inclined at 26°30’ to the vertical axis, for M5 screws.
DE9RA1212
(PG 13 to 1/2" NPT adapter)
1. Tapped entry for 1/2" NPT conduit
2. PG 13 threaded sleeve
14,65
35,6
5,5
14,65
(1)
105
5
(2)
Ø10
35
Ø
81
11,5
77
61,5==
6,2
6,5
(1) (1)
4
35,6
14,65
123,2
5,5
15
(1)
5
(2)
Ø13
54,5
Ø
81
11,5
77
61,5==
6,2
6,5
(1) (1)
8
35,6
5,5
15
5
(1)
129
14,65
(2)
Ø20
59
Ø
81
11,5
77
61,5==
6,2
6,5
(1) (1)
5,5
5,5
22 15,45
35,6
15
(1)
(1) (1)
135
5
(2)
21.3(2
)
(1)
25.4
20.4
98
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ
b XCKJ
fixed, non-plug-in body with 1 cable entry
v With head for linear movement (plunger)
Page 100
v With head for rotary movement (lever) or multi-directional
Page 100
b XCKJ
plug-in body with 1 cable entry
v With head for linear movement (plunger)
Page 102
v With head for rotary movement (lever)
Page 102
Environmental characteristics
Conforming to standards Products IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C22-2 n° 14
Machine assemblies IEC 60204-1, EN 60204-1
Product certifications UL, CSA, CCC
Protective treatment Version Standard “TC”, special “TH”
Ambient air temperature Operation - 25…+70 °C (-13…+158 °F),
special sub-assemblies available for extreme temperatures: -40 °C (-40 °F) or +120 °C (248 °F)
Storage - 40…+70 °C (-40…+158 °F)
Vibration resistance Conforming to IEC 60068-2-6 25 gn (10…500 Hz)
Shock resistance Conforming to IEC 60068-2-27 50 gn (11 ms)
Electric shock protection Class I conforming to IEC 61140 and NF C 20-030
Degree of protection NEMA Types 1, 2, 4, 12; IP 66 conforming to IEC 60529; IK 07 conforming to EN 50 102
Repeat accuracy 0.01 mm on the tripping points, with 1 million operating cycles for head with end plunger
Cable entry or integral connector Depending on model Tapped entry for PG 13 conduit thread, or tapped ISO M20 x 1.5 or 1/2" NPT, or M12 connector
Materials Bodies and heads in Zamak® zinc alloy
561646
561647
561648
561649
561650
561651
561652
561653
561654
561655
99
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ
Contact block characteristics
Rated operational
characteristics
XE2•P a AC-15; A300 (Ue = 240 V, Ie = 3 A); Ithe = 10 A
c DC-13; Q300 (Ue = 250 V, Ie = 0.27 A), conforming to IEC 60947-5-1 appendix A, EN 60947-5-1
XE3•P a AC-15; B300 (Ue = 240 V, Ie = 1.5 A); Ithe = 6 A
c DC-13; R300 (Ue = 250 V, Ie = 0.1 A), conforming to IEC 60947-5-1 appendix A, EN 60947-5-1
Rated insulation voltage
XE2•P Ui = 500 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
XE3•P Ui = 400 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Rated impulse withstand
voltage
XE2•P U imp = 6 kV conforming to IEC 60947-1, IEC 60664
XE3•P U imp = 4 kV conforming to IEC 60947-1, IEC 60664
Positive operation (depending on model) N/C contacts with positive opening operation conforming to IEC 60947-5-1 Appendix K, EN 60947-5-1
Resistance across terminals y 25 mΩ conforming to IEC 60255-7 category 3
Short-circuit protection XE2•P 10 A cartridge fuse type gG (gl)
XE3•P 6 A cartridge fuse type gG (gl)
Cabling
(screw clamp terminals)
XE2SP21•1 Clamping capacity, min: 1 x 0.34 mm
2
, max: 2 x 1.5 mm
2
XE2NP21•1 Clamping capacity, min: 1 x 0.5 mm
2
, max: 2 x 2.5 mm
2
XCKJ plug-in and XESP20•1 Clamping capacity, min: 1 x 0.75 mm
2
, max: 2 x 1.5 mm
2
XE3NP and XE3SP Clamping capacity, min: 1 x 0.34 mm
2
, max: 1 x 1 mm
2
or 2 x 0.75 mm
2
Minimum actuation speed XE2SP21•1 and XE3SP: 0.01 m/minute (0.03 ft/minute)
XE2NP21•1 and XE3NP: 6 m/minute (19.68 ft/minute)
Electrical durability
•Conforming to IEC 60947-5-1 Appendix C
•Utilization categories AC-15 and DC-13
•Maximum operating rate: 3600 operating cycles/hour
•Load factor: 0.5
XE2SP21•1, XE2SP2141 XE2NP21•1 XCKJ plug-in, XESP20•1
a.c. supply
a 50/60 Hz
o inductive circuit
d.c. supply cPower switched in W for 5 million
operating cycles.
Power switched in W for 5 million
operating cycles.
Power switched in W for 5 million
operating cycles.
Voltage V 24 48 120 Voltage V 24 48 120 Voltage V 24 48 120
oW10 7 4 oW13 9 7 oW10 7 4
For XE2SP•151 on
a
or
c
, N/C and N/O contacts simultaneously loaded to the values shown with reverse polarity.
XE3NP•••• XE3SP••••
a.c. supply
a 50/60 Hz
o inductive circuit
d.c. supply c
Power switched in W for 5 million
operating cycles.
Power switched in W for 5 million
operating cycles.
Voltage V 24 48 120 Voltage V 24 48 120
oW321oW432
Millions of operating cycles
Current in A
0,1
0,5
1
5
0,5 1 5 10
110 V
48 V
230/400 V
234
Ithe
24 V
0,5 1 2 3 4 5 10
0,1
0,2
0,5
1
5
2
4
3
Ithe
230 V
12/24/48 V
110 V
Millions of operating cycles
Current in A
Millions of operating cycles
Current in A
0,5 1 2 5 10
0,1
0,5
1
5
2
3
4
230 V 48 V
Ithe
12/24 V
34
110 V
0,1
0,5
1
5
0,5 1 5 10
110 V
48 V
230/400 V
234
Ithe
24 V
Millions of operating cycles
Current in A
0,5 1 2 3 4 5 10
0,1
0,2
0,5
1
5
2
4
3
Ithe
230 V
110 V
12/24/48 V
Millions of operating cycles
Current in A
100
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Complete Switches, Fixed Non-plug-in Body, 1/2" NPT Cable Entry
Type of head Plunger (mounting by the body) Rotary (mounting by the body)
(switches supplied for actuation from left AND right)
Form B (1) Form C (1) Form A (1) Form D (1)
Type of operator Metal end plunger Steel roller plunger Thermoplastic roller lever
(3)
Steel roller lever (3) Variable length
thermoplastic roller lever
(3)
Round thermoplastic rod
lever, Ø 6 mm (0.24 in.)
(3) (4)
Catalog numbers (2)
2-pole N/C +
N/O
snap action
(XE2S P2151)
XCKJ161 XCKJ167 XCKJ10511 XCKJ10513 XCKJ10541 XCKJ10559
2-pole N/C +
N/O break
before make,
slow break
(XE2N P2151)
XCKJ561 XCKJ567 XCKJ50511 XCKJ50513 XCKJ50541 XCKJ50559
2-pole N/C + N/C
snap action
(XE2S P2141)
ZCKJ9 +
ZCKE61
ZCKJ9 +
ZCKE67
ZCKJ9 +
ZCKE05 + ZCKY11
ZCKJ9 +
ZCKE05 + ZCKY13 ZCKJ9 +
ZCKE05 + ZCKY41
ZCKJ9 +
ZCKE05 + ZCKY59
2-pole N/C + N/C
simultaneous,
slow break
(XE2N P2141)
ZCKJ7 +
ZCKE61
ZCKJ7 +
ZCKE67
ZCKJ7 +
ZCKE05 + ZCKY11
ZCKJ7 +
ZCKE05 + ZCKY13 ZCKJ7 +
ZCKE05 + ZCKY41
ZCKJ7 +
ZCKE05 + ZCKY59
3-pole
N/C + N/C +
N/O
snap action
(XE3S P2141)
ZCKJD39 +
ZCKE61
ZCKJD39 +
ZCKE67
ZCKJD39 +
ZCKE05 + ZCKY11
ZCKJD39 +
ZCKE05 + ZCKY13 ZCKJD39 +
ZCKE05 + ZCKY41
ZCKJD39 +
ZCKE05 + ZCKY59
3-pole
N/C + N/C +
N/O break
before make,
slow break
(XE3N P2141)
ZCKJD37 +
ZCKE61
ZCKJD37 +
ZCKE67
ZCKJD37 +
ZCKE05 + ZCKY11
ZCKJD37 +
ZCKE05 + ZCKY13 ZCKJD37 +
ZCKE05 + ZCKY41
ZCKJD37 +
ZCKE05 + ZCKY59
Weight, kg (lb) 0.430 (0.948) 0.455 (1.003) 0.480 (1.058) 0.490 (1.080) 0.485 (1.069) 0.485 (1.069)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when
properly mounted and using a conforming operator
Characteristics
Switch actuation On end By 30° cam By any moving part
Type of actuation
Maximum actuation
speed 0.5 m/s (1.64 ft/s) 1 m/s (3.28 ft/s) 1.5 m/s (4.92 ft/s)
Minimum
force or
torque
For tripping 20 N (4.50 lb) 16 N (3.60 lb) 0.25 N•m (2.21 lb-in)
For positive
opening 50 N (11.24 lb) 40 N (8.99 lb) 0.50 N•m (4.43 lb-in) —
Cable entry 1 entry tapped 1/2" NPT for ISO cable entry, clamping capacity 9 to 12 mm (0.35 to 0.47 in.)
1. Form conforming to EN 50041. See page 23.
2. Switches with gold contacts or eyelet type connections: please consult your local sales office.
3. Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever or its mounting.
4. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mounting.
1314
22 21
2 4,7(P)
6
mm
13-14
21-22
21-22
13-14
0
0,9
3,2(A) 8,1(P)
mm
13-14
21-22
21-22
13-14
0
1,5
23˚ 58˚(P)
90˚
13-14
21-22
21-22
13-14
0
11˚
23˚ 58˚(P)
90˚
13-14
21-22
21-22
13-14
0
11˚
23˚
90˚
13-14
21-22
21-22
13-14
0
11˚
23˚
90˚
13-14
21-22
21-22
13-14
0
11˚
1314
22 21
2 3,4(P)
6
mm
13-14
21-22
0 3,2
3,2(A) 5,9(P)
mm
13-14
21-22
0 5,3
23˚ 40˚(P)
90˚
13-14
21-22
0 33˚
23˚ 40˚(P)
90˚
13-14
21-22
0 33˚
23˚
90˚
13-14
21-22
0 33˚
23˚
90˚
13-14
21-22
0 33˚
12 11
22 21
2 4,7(P)
6
mm
21-22
11-12
11-12
21-22
0
0,9
21-22
11-12
11-12
21-22
3,2(A) 8,1(P)
mm
0
1,5
21-22
11-12
11-12
21-22
23˚ 58˚(P)
90˚
0
11˚
21-22
11-12
11-12
21-22
23˚ 58˚(P)
90˚
0
11˚
21-22
11-12
11-12
21-22
23˚
90˚
0
11˚
21-22
11-12
11-12
21-22
23˚
90˚
0
11˚
12 11
22 21
2
3,4(P)
6
mm
0
21-22
11-12
3,5(A)
5,9(P)
mm
0
21-22
11-12
28˚
62˚(P)
90˚
21-22
11-12
028˚
62˚(P)
90˚
21-22
11-12
028˚ 90˚
21-22
11-12
028˚ 90˚
21-22
11-12
0
32 31
22 21
1314
13-14
21-22
31-32
6
mm
13-14
0
0,9
2 4,7(P)
31-32
21-22
13-14
21-22
31-32
13-14
31-32
21-22
mm
0
1,5
3,2(A) 8,1(P)
13-14
21-22
31-32
13-14
31-32
21-22
90˚
0
11˚
23˚ 58˚(P)
13-14
21-22
31-32
13-14
31-32
21-22
90˚
0
11˚
23˚ 58˚(P)
13-14
21-22
31-32
13-14
31-32
21-22
90˚
0
11˚
23˚
13-14
21-22
31-32
13-14
31-32
21-22
090˚
32 31
22 21
14 13
6
mm
13-14
31-32
0 3,2
2 3,4(P)
21-22
mm
13-14
31-32
0 5,3
3,2(A) 5,9(P)
21-22
90˚
13-14
31-32
0 33˚
23˚ 40˚(P)
21-22
90˚
13-14
31-32
0 33˚
23˚ 40˚(P)
21-22
90˚
13-14
31-32
0 33˚
23˚
21-22
13-14
31-32
21-22
101
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Complete Switches, Fixed Non-plug-in Body, 1/2" NPT Cable Entry
For Interpretation of the Complete Switch Catalog Number Only
Note: See following pages for the complete switch offering
XCKJ•61
ZCKJ•+ ZCKE61
XCKJ•67
ZCKJ• + ZCKE67
XCKJ•051•
ZCKJ• + ZCKE05 + ZCKY11 or Y13
XCKJ•0541
ZCKJ• + ZCKE05 + ZCKY41
XCKJ•0559
ZCKJ• + ZCKE05 + ZCKY59
1. 1 tapped entry for 1/2" NPT.
2. Rod Ø 6 mm (0.24 in.), length 200 mm (7.87 in.).
3. 282 max.
4. 190 max.
5. 212 max.
Ø: 2 elongated holes Ø 5.3 x 7.3.
33,5
17
44
107
(1)
37
60
30
40
=
=
50
60
30
40
=
=
33,5
17
44
120
(1)
5
63
60
30
40
=
=
41
33,5
57
62
5
133
41
(1)
62…107
60
30
40
=
=
40…85
33,5
52
60
5,5
132…177
(1)
44
33,5
48
60
(3)
(1)
(5)
60
30
40
=
=
(4)
26,2
(2)
XCKJ ——— —— ——
Head type
05—Rotary
09—Rotary maintained
61—Top rod plunger
67—Top roller plunger
Levers
11—Delrin® roller
13—Steel roller
41—Adjustable Delrin roller
59—Round plastic rod
Z—component
X—complete
Switch type
1 SPDT Non-plug-in
2 2SPDT Non-plug-in
4 2SPDT Non-plug-in for 2 step or neutral position
5 SPDT Non-plug-in slow make slow break
8 SPDT Gold Contacts
11 SPDT Plug-in
21 2SPDT Plug-in
41 2SPDT Plug-in for 2 step or neutral position
102
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Complete Switches, Plug-in Body, 1/2" NPT Cable Entry
Type of head Plunger (mounting by the body) Rotary (mounting by the body)
(switches supplied for actuation from left AND right)
Form B (1) Form C (1) Form A (1) Form D (1)
Type of operator Metal end
plunger Steel roller plunger Thermoplastic roller
lever (3) Steel roller lever (3)
Variable length
thermoplastic roller
lever (3)
Round thermoplastic rod
lever, Ø 6 mm (0.24 in.)
(3) (4)
Catalog numbers (2)
Single-pole C/O
snap action
XCKJ1161 XCKJ1167 XCKJ110511 XCKJ110513 XCKJ110541 XCKJ110559
Weight, kg (lb) 0.430 (0.948) 0.455 (1.003) 0.480 (1.058) 0.490 (1.080) 0.485 (1.069) 0.485 (1.069)
Contact operation contact
closed
contact
open
(A) = cam displacement
Characteristics
Switch actuation On end By 30° cam By any moving part
Type of actuation
Maximum actuation speed 0.5 m/s
(1.64 ft/s) 1 m/s (3.28 ft/s) 1.5 m/s (4.92 ft/s)
Minimum force or torque for tripping 20 N (4.50 lb) 16 N (3.60 lb) 0.25 N•m (2.21 lb-in)
Cable entry 1 entry tapped for 1/2" NPT cable entry.
Clamping capacity 7 to 13 mm (0.28 to 0.51 in.)
1. Form conforming to EN 50041. See page 23.
2. Switches with gold contacts: please consult your local sales office.
3. Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting or clamp.
4. Value taken with actuator operating at 100 mm (3.94 in.) from the mounting.
12 11
13
14
2
06mm
0,9
11-12
13-14
11-12
13-14
3,2(A)
0mm
1,5
11-12
13-14
11-12
13-14
11-12
13-14
11-12
13-140
11-12
13-14
11-12
13-140
11-12
13-14
11-12
13-140
11-12
13-14
11-12
13-140
103
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Complete Switches, Plug-in Body, 1/2" NPT Cable Entry
XCKJ1611 XCKJ1167 XCKJ110511, XCKJ110513
XCKJ110541 XCKJ110559
1. Tapped entry for 1/2" NPT conduit.
2. Rod Ø 6 mm (0.24 in.), length 200 mm (7.87 in.).
3. 289 max.
4. 190 max.
5. 212 max.
36
25
114
17
(1)
42,5
30
==
60 37
(1)
42,5
30
==
60 50
36
25
127
17
5
63
60
30
42,5
=
=
41
(1)
25
57
62
5
140
41
25
52
60
5,5
139…184
44
62…107
60
30
42,5
=
=
40…85
(1)
60
25
(3)
48
(1)
42,5
30
==
60 (5)
(4)
26,2
(2)
104
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Complete Switches, Fixed Non-plug-in Body, Integral M12 Connector
Type of head Plunger (mounting by the body) Rotary (mounting by the body)
(switches supplied for actuation from left AND right)
Form B (1) Form C (1) Form A (1) Form D (1)
Type of operator
Metal end
plunger Steel roller plunger Thermoplastic roller
lever (2) Steel roller lever (2)
Variable length
thermoplastic roller
lever (2)
Round thermoplastic rod
lever, Ø 6 mm (0.24 in.)
(2) (3)
Catalog numbers (4)
2-pole N/C + N/O
snap action (XE2SP2151)
XCKJ161D XCKJ167D XCKJ10511D XCKJ10513D
XCKJ10541D XCKJ10559D
Weight, kg (lb) 0.430 (0.948) 0.455 (1.003) 0.480 (1.058) 0.490 (1.080) 0.485 (1.069) 0.485 (1.069)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
Characteristics
Switch actuation On end By 30° cam By any moving part
Type of actuation
Maximum actuation speed 0.5 m/s (
1.64 ft/s) 1 m/s (3.28 ft/s) 1.5 m/s (4.92 ft/s)
Minimum force or
torque
For tripping 20 N (4.50 lb) 16 N (3.60 lb) 0.25 N•m (2.21 lb-in)
For positive opening 50 N (11.24 lb) 40 N (8.99 lb) 0.50 N•m (4.43 lb-in) — —
Connection M12 5-pin connector, Ui = 60 V, Ie = 4 A (see suitable pre-wired female connectors below).
1. Form conforming to EN 50041. See page 23.
2. Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever or its mounting.
3. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mounting.
4. Switches with gold contacts: please consult your local sales office.
Catalog numbers of suitable pre-wired female connectors
Type of connector Length (L) M12 straight, 5-pin, 4 A/24 V max. M12 elbowed, 5-pin, 4 A/24 V max. Weight, kg (lb)
With cable, Ø 5.8 mm
(0.23 in.)
(4 x 0.34 mm
2
+ 1 x 0.5 mm
2
)
2 m (6.56 ft) XZCP1164L2 XZCP1264L2 0.115 (0.254)
5 m (16.40 ft) XZCP1164L5 XZCP1264L5 0.270 (0.595)
10 m (32.8 ft) XZCP1164L10 XZCP1264L10 0.520 (1.146)
1314
22 21
2
21-22
13-14
21-22
13-14
0
4,7(P)
0,9
6mm
3,2(A)
0mm
1,5
8,1(P)
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14
105
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Complete Switches, Fixed Non-plug-in Body, Integral M12 Connector
Dimensions
XCKJ161D XCKJ167D XCKJ1051•D
XCKJ10541D XCKJ10559D XZCP1164L•
XZCP1264L•
1. Rod Ø 6 mm (0.24 in.), length 200 mm (7.87 in.)
2. 282 max.
3. 190 max.
4. 212 max.
Ø: 2 elongated holes Ø 5.3 x 7.3
L: Cable length 2, 5, or 10 m (6.6, 16.4, or 32.8 ft)
Connections
Limit switch XCKJ••••DPre-wired female connector XZCP1•64L•
1-2 = N/C
3-4 = N/O
5 = t
4 A / 24 V max.
1 = brown
2 = white
3 = blue
4 = black
5 = t yellow/green
17
107
33,5
44
12
37
60
30
40
=
=
17
120
5
33,5
44
12
50
60
30
40
=
=
57
5
133
41
33,5
62
12
63
60
41
30
40
=
=
52
5,5
132…177
44
33,5
59
12
62…107
60
40…85
30
40
=
=33,5
48
59
(2)12
(4)
60
30
40
=
=
(3)
26,2
(1)
42 L
32
26
L
40
20
3
4
2
13
4
2
1
1314
22 21
106
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Complete Switches, Fixed Non-plug-in Body, Integral 7/8" 16UN connector
Type of head Plunger (mounting by the body) Rotary (mounting by the body)
(switches supplied for actuation from left AND right)
Form B (1) Form C (1) Form A (1) Form D (1)
Type of operator Metal end
plunger Steel roller plunger Thermoplastic roller
lever (2) Steel roller lever (2)
Variable length
thermoplastic roller
lever (2)
Round thermoplastic rod
lever, Ø 6 mm (0.24 in.)
(2) (3)
Catalog numbers (4)
2-pole N/C + N/O
snap action (XE2SP2151)
XCKJ161A XCKJ167A XCKJ10511A XCKJ10513A
XCKJ10541A XCKJ10559A
Weight, kg (lb) 0.430 (0.948) 0.455 (1.003) 0.480 (1.058) 0.490 (1.080) 0.485 (1.069) 0.485 (1.069)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening
operation, when properly mounted and using a
conforming operator
Characteristics
Switch actuation On end By 30° cam By any moving part
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1 m/s (3.28 ft/s) 1.5 m/s (4.92 ft/s)
Minimum force
or torque
For tripping 20 N (4.50 lb) 16 N (3.60 lb) 0.25 N•m (2.21 lb-in)
For positive opening 50 N (11.24 lb) 40 N (8.99 lb) 0.50 N•m (4.43 lb-in) — —
Connection 7/8" 16UN 5-pin connector, Ui = 250 V; Ie = 6 A (see suitable pre-wired female connectors below).
1. Form conforming to EN 50041. See page 23.
2. Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting or clamp.
3. Value taken with actuator operating at 100 mm (3.94 in.) from the mounting.
4. Switches with gold contacts: please consult your local sales office.
Catalog numbers of suitable pre-wired female connectors
Type of connector Length (L) 7/8" 16UN straight, 5-pin, 6 A/250 V max. Weight, kg (lb)
With cable, Ø 6.7 mm
(5 x 0.5 mm
2
)
2 m (6.56 ft) XZCP1771L2 0.190 (0.419)
5 m (16.40 ft) XZCP1771L5 0.475 (1.047)
10 m (32.8 ft) XZCP1771L10 0.950 (2.094)
1314
22 21
2
21-22
13-14
21-22
13-14
0
4,7(P)
0,9
6mm
3,2(A)
0mm
1,5
8,1(P)
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14 0
21-22
13-14
21-22
13-14
107
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Complete Switches, Fixed Non-plug-in Body, Integral 7/8" 16UN connector
Dimensions
XCKJ161A XCKJ167A XCKJ1051•A
XCKJ10541A XCKJ10559A XZCP1771L•
1. Rod Ø 6 mm (0.24 in.), length 200 mm (7.87 in.)
2. 282 max.
3. 190 max.
4. 212 max.
Ø: 2 elongated holes Ø 5.3 x 7.3
L: cable length: 2, 5, or 10 m (6.6, 16.4, or 32.8 ft)
Connections
Limit switch XCKJ••••APre-wired female connector XZCP1771L•
1 = 21
2 = 22
3 = t
4 = 14
5 = 13
1 = black
2 = blue
3 = yellow/green t
4 = brown
5 = white
17
107
33,5
44
17
37
60
30
40
=
=
17
120
5
33,5
44
17
50
60
30
40
=
=
57
5
133
41
33,5
62
17
63
60
41
30
40
=
=
52
5,5
132…177
44
33,5
59
17
62…107
60
40…85
30
40
=
=33,5
48
59
(2)17
(4)
60
30
40
=
=
(3)
26,2
(1)
55 L
5
24
3
15
24
3
1
1314
22 21
108
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies
1. Cannot be used with bodies ZCKJ4 and ZCKJ41.
2. For further details, see page 110.
3. For a cable entry tapped ISO M20 x 1.5, add H29 to the catalog number. Example: ZCKJ1 becomes ZCKJ1H29.
For a cable entry tapped 1/2" NPT, do not add an H code to the catalog number. Example: ZCKJ1.
ZCK E67 ZCK E629
ZCK E61 ZCK E66 ZCK E619
ZCK E08 ZCK E06
ZCK E21 ZCK E23
ZCK E63 ZCK E64 ZCK E65
ZCK J1D, J5D, J6D, J7D
ZCK J8D
ZCK JD3p,
ZCK J1, J5, J6, J7, J9
ZCK J2, J8
ZCK J11, J21, J41
ZCK E62
ZCK J4
Thermoplastic roller
lever plunger,
1 direction of actuation
Steel roller
lever plunger,
1 direction of actuation
Side metal
plunger
Side steel roller
plunger,
horizontal (1)
Spring rod
Side steel roller
plunger,
vertical (1)
Cat’s whisker
End reinforced
steel roller plunger
End steel roller
plunger with
protective boot
End steel roller
plunger
End metal
plunger
End steel ball
bearing plunger
End metal plunger
with protective boot
Body with 2-pole contact, fixed,
1 step,
M12 connector (2)
Body with contact, cable
entry for PG 13, fixed,
1 step (2) (3)
Body with contact, cable
entry for PG 13, fixed,
1 step (2) (3)
Body with contact, cable
entry for PG 13, fixed,
2 step (2) (3)
Body with contact, cable
entry for PG 13, plug-in,
1 or 2 step (2) (3)
109
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies
: head assuring positive opening operation, when properly mounted and using a conforming operator.
4. Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.
5. Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting.
ZCK E05
ZCK E09 ZCK Y61ZCK Y71
ZCK Y13 ZCK Y14ZCK Y11
ZCK Y41 ZCK Y43
ZCK Y81 ZCK Y91
ZCK Y53 ZCK Y52 ZCK Y59ZCK Y51
ZCK J404 ZCK J4104
Square rod lever,
steel, U 3 (0.12)
L = 125 (4.92) (5)
Round rod lever,
steel, Ø 3 (0.12)
L = 125 (4.92) (5)
Round rod
lever, glass
fibre,
Ø 3 (0.12)
L = 125 (4.92)
(5)
Round rod lever,
thermoplastic,
Ø 6 (0.24)
L = 200 (7.87) (5)
Spring lever with
thermoplastic end
(4)
Spring-rod lever,
metal (4)
Variable length
thermoplastic roller
lever (4)
Variable length
steel roller
lever (4)
Thermoplastic roller
lever (5)
Steel ball bearing
mounted roller lever (5)
Spring
return, for
actuation
from left
AND right
or
from left OR
right
Stay put, for
actuation from
left AND right
Forked arm with
thermoplastic
rollers, 1 track (5)
Forked arm with
thermoplastic rollers,
2 track (5)
Fixed body with one SPDT contact switch per
direction: past 20° CW contact 1 (11–12 / 13–14)
switches; past 20° CCW contact 2
(21–22 / 23–24) switches (3)
Plug-in body with one SPDT contact switch per
direction: past 20° CW contact 1
(11–12 / 13–14) switches; past 20° CCW
contact 2 (21–22 / 23–24) switches (3)
Steel roller
lever (5)
Dimensions: mm (in.)
110
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies with 1/2" NPT Cable Entry
Fixed bodies with 2-pole contact
Type With contact
block
Function
diagram
Positive
operation (1) Cable entry Catalog number Weight
kg (lb)
1 step
N/C + N/O
snap action
(XE2S P2151)
1/2" NPT ZCKJ1 0.310
(0.683)
ISO M20 x 1.5 ZCKJ1H29 0.310
(0.683)
2 C/O
simultaneous,
snap action
(XES P2021)
—
1/2" NPT ZCKJ2 0.310
(0.683)
ISO M20 x 1.5 ZCKJ2H29 0.310
(0.683)
N/C + N/O
break before make,
slow break
(XE2N P2151)
1/2" NPT ZCKJ5 0.310
(0.683)
ISO M20 x 1.5 ZCKJ5H29 0.310
(0.683)
N/C + N/O
make before make,
slow break
(XE2N P2161)
1/2" NPT ZCKJ6 0.310
(0.683)
ISO M20 x 1.5 ZCKJ6H29 0.310
(0.683)
N/C + N/C
simultaneous,
slow break
(XE2N P2141)
1/2" NPT ZCKJ7 0.310
(0.683)
ISO M20 x 1.5 ZCKJ7H29 0.310
(0.683)
N/O + N/O
simultaneous,
slow break
(XE2N P2131)
—
1/2" NPT ZCKJ8 0.310
(0.683)
ISO M20 x 1.5 ZCKJ8H29 0.310
(0.683)
N/C + N/C
snap action
(XE2S P2141)
1/2" NPT ZCKJ9 0.310
(0.683)
ISO M20 x 1.5 ZCKJ9H29 0.310
(0.683)
2 step
2 C/O
staggered,
snap action
(XES P2031)
—
1/2" NPT ZCKJ4 0.310
(0.683)
ISO M20 x 1.5 ZCKJ4H29 0.310
(0.683)
Fixed bodies with 3-pole contact
Type With contact
block
Function
diagram
Positive
operation (1) Cable entry Catalog number Weight
kg (lb)
—
N/C + N/O + N/O
snap action
(XE3S P2151)
1/2" NPT ZCKJD31 0.310
(0.683)
ISO M20 x 1.5 ZCKJD31H29 0.310
(0.683)
N/C + N/C + N/O
snap action
(XE3S P2141)
1/2" NPT ZCKJD39 0.310
(0.683)
ISO M20 x 1.5 ZCKJD39H29 0.310
(0.683)
N/C + N/C + N/O
break before make,
slow break
(XE3N P2141)
1/2" NPT ZCKJD37 0.310
(0.683)
ISO M20 x 1.5 ZCKJD37H29 0.310
(0.683)
N/C + N/O + N/O
break before make,
slow break
(XE3N P2151)
1/2" NPT ZCKJD35 0.310
(0.683)
ISO M20 x 1.5 ZCKJD35H29 0.310
(0.683)
1. : N/C contact with positive opening operation, when properly mounted and using a conforming operator.
22 21
13
14
22 21
23
24
12 11
13
14
22 21
13
14
22 21
14 13
12 11
22 21
1314
24 23
12 11
22 21
22 21
23
24
12 11
13
14
32 31
1314
3334
32 31
22 21
1314
32 31
22 21
1314
22 21
1314
3334
111
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies with 1/2" NPT Cable Entry
Plug-in bodies with contact
Type With contact
block
Function
diagram
Positive
operation
(1)
Cable entry Catalog number Weight
kg (lb)
1 step
Single-pole C/O
snap action
—
1/2" NPT ZCKJ11 0.300
(0.661)
ISO M20 x 1.5 ZCKJ11H29 0.300
(0.661)
Double-pole 2 C/O
simultaneous,
snap action
—
1/2" NPT ZCKJ21 0.300
(0.661)
ISO M20 x 1.5 ZCKJ21H29 0.300
(0.661)
2 step
Double-pole 2 C/O
staggered,
snap action
—
1/2" NPT ZCKJ41 0.300
(0.661)
ISO M20 x 1.5 ZCKJ41H29 0.300
(0.661)
Bodies with contact, with rotary head (without operating lever)
Type With contact
block
Function
diagram
Positive
operation
(1)
Cable entry Catalog number Weight
kg (lb)
Fixed non-plug-in body
Neutral position
1 from the left AND
1 from the right
One SPDT contact
switch per direction:
past 20° CW contact
1 (11–12 / 13–14)
switches; past 20°
CCW contact 2
(21–22 / 23–24)
switches
—
1/2" NPT ZCKJ404 0.455
(1.003)
ISO M20 x 1.5 ZCKJ404H29 0.455
(1.003)
Plug-in body
Neutral position
1 from the left AND
1 from the right
One SPDT contact
switch per direction:
past 20° CW contact
1 (11–12 / 13–14)
switches; past 20°
CCW contact 2
(21–22 / 23–24)
switches
—
1/2" NPT ZCKJ4104 0.465
(1.025)
ISO M20 x 1.5 ZCKJ4104H29 0.465
(1.025)
Plug-in housing switch top only
Description For use with Contacts Catalog number Weight
kg (lb)
Single-pole 1 C/O
with positive opening operation ZCKJ11 Silver ZCKJ01 0.150
(0.331)
Double-pole 2 C/O simultaneous
with positive opening operation ZCKJ21 Silver ZCKJ02 0.160
(0.353)
Double-pole 1 C/O + 1 C/O neutral position ZCKJ41 Silver ZCKJ04 0.160
(0.353)
1. : N/C contact with positive opening operation, when properly mounted and using a conforming operator.
12 11
13
14
ZCKJ•1
22 21
23
24
12 11
13
14
22 21
23
24
12 11
13
14
22 21
23
24
12 11
13
14
ZCKJ404
22 21
23
24
12 11
13
14
ZCKJ0•
112
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies with 1/2" NPT Cable Entry
With Indicator Light Module
Fixed non-plug-in bodies with 2-pole contact
Type With contact
block
Function
diagram
Positive
operation (1) Cable entry Catalog number Weight
kg (lb)
With module comprising 1 LED, 24 Vc
1 step
N/C + N/O
snap action
(XE2S P2151)
1/2" NPT ZCKJ120 0.320
(0.705)
N/C + N/O
break before make,
slow break
(XE2N P2151)
1/2" NPT ZCKJ520 0.320
(0.705)
With module comprising 2 LEDs, 24 Vc
1 step
N/C + N/O
snap action
(XE2S P2151)
1/2" NPT ZCKJ121 0.320
(0.705)
ISO M20 x 1.5 ZCKJ121H29 0.320
(0.705)
N/C + N/O
break before make,
slow break
(XE2N P2151)
1/2" NPT ZCKJ521 0.320
(0.705)
ISO M20 x 1.5 ZCKJ521H29 0.320
(0.705)
With module comprising 2 neon indicator lights, 110/120 Va
1 step
N/C + N/O
snap action
(XE2S P2151)
1/2" NPT ZCKJ133 0.320
(0.705)
ISO M20 x 1.5 ZCKJ133H29 0.320
(0.705)
N/C + N/O
break before make,
slow break
(XE2N P2151)
1/2" NPT ZCKJ533 0.320
(0.705)
ISO M20 x 1.5 ZCKJ533H29 0.320
(0.705)
With module comprising 2 neon indicator lights, 220/240 Va
1 step
N/C + N/O
snap action
(XE2S P2151)
1/2" NPT ZCKJ134 0.320
(0.705)
ISO M20 x 1.5 ZCKJ134H29 0.320
(0.705)
1/2" NPT ZCKJ534 0.320
(0.705)
N/C + N/O
break before make,
slow break
(XE2N P2151) ISO M20 x 1.5 ZCKJ534H29 0.320
(0.705)
Plug-in bodies with single-pole contact
Type With contact
block
Function
diagram
Positive
operation (1) Cable entry Catalog number Weight
kg (lb)
With module comprising 2 LEDs, 24 Vc
1 step C/O
snap action —
1/2" NPT ZCKJ1121 0.340
(0.750)
ISO M20 x 1.5 ZCKJ1121H29 0.340
(0.750)
With module comprising 2 neon indicator lights, 110/120 Va
1 step C/O
snap action —
1/2" NPT ZCKJ1133 0.340
(0.750)
ISO M20 x 1.5 ZCKJ1133H29 0.340
(0.750)
With module comprising 2 neon indicator lights, 220/240 Va
1 step C/O
snap action —
1/2" NPT ZCKJ1134 0.340
(0.750)
ISO M20 x 1.5 ZCKJ1134H29 0.340
(0.750)
1. : N/C contact with positive opening operation, when properly mounted and using a conforming operator.
Indicator light module characteristics
Type of indicator 1 LED or 2 LEDs 2 neon lights
Rated insulation voltage c 50 V, conforming to IEC 60947-1 250 Va, conforming to IEC 60947-1
Current consumption 7 mA per LED 2.5 mA per neon 5 mA per neon
Rated operational voltage 24 Vc 110/120 Va 220/240 Va
Voltage limits 20…30 Vc (including ripple) 95…130 Va 190…260 Va
Service life 100 000 hours 20 000 hours 20 000 hours
Reverse polarity protection Ye s —
22 21
13
14
22 21
13
14
22 21
13
14
22 21
13
14
22 21
13
14
22 21
13
14
22 21
13
14
22 21
13
14
12 11
13
14
12 11
13
14
12 11
13
14
113
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in Bodies with M12 Connector
Fixed bodies with 2-pole contact
Type With contact
block Function diagram Positive
operation (1) Catalog number Weight
kg (lb)
1 step
N/C + N/O
snap action
(XE2S P2151)
ZCKJ1D 0.320
(0.705)
N/C + N/O
break before make,
slow break
(XE2N P2151)
ZCKJ5D 0.320
(0.705)
N/O + N/C
make before make,
slow break
(XE2N P2161)
ZCKJ6D 0.320
(0.705)
N/C + N/C
simultaneous,
slow break
(XE2N P2141)
ZCKJ7D 0.320
(0.705)
N/O + N/O
simultaneous,
slow break
(XE2N P2131)
—ZCKJ8D 0.320
(0.705)
1. N/C contact with positive opening operation, when properly mounted and using a conforming operator.
22 21
13
14
22 21
13
14
22 21
14 13
12 11
22 21
1314
24 23
114
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies with 1/2" NPT Cable Entry
Low-Temperature Applications (–40 °F / –40 °C)
Body with contacts—For plunger or rotary head
Type Contact block Function
diagram
Positive
operation
(1)
Cable entry Catalog
number
Weight
kg (lb)
Fixed non-plug-in body
1 step
2-pole 1 N/C + 1 N/O
snap action
(XE2SP2151)
1/2" NPT ZCKJ1 0.310
(0.683)
ISO M20 x 1.5 ZCKJ1H29 0.310
(0.683)
Double-pole 2 C/O
simultaneous
snap action
(XESP2021)
—
1/2" NPT ZCKJ2 0.310
(0.683)
ISO M20 x 1.5 ZCKJ2H29 0.310
(0.683)
2-pole 1 N/C + 1 N/O
break before make
slow break
(XE2NP2151)
1/2" NPT ZCKJ5 0.310
(0.683)
ISO M20 x 1.5 ZCKJ5H29 0.310
(0.683)
2-pole 1 N/O + 1 N/C
make before break
slow break
(XE2NP2161)
1/2" NPT ZCKJ6 0.310
(0.683)
ISO M20 x 1.5 ZCKJ6H29 0.310
(0.683)
2-pole 1 N/C + 1 N/C
simultaneous
slow break
(XE2NP2141)
1/2" NPT ZCKJ7 0.310
(0.683)
ISO M20 x 1.5 ZCKJ7H29 0.310
(0.683)
2-pole 1 N/O + 1 N/O
simultaneous
slow break
(XE2NP2131)
—
1/2" NPT ZCKJ8 0.310
(0.683)
ISO M20 x 1.5 ZCKJ8H29 0.310
(0.683)
2-pole 1 N/C + 1 N/C
snap action
(XE2SP2141)
1/2" NPT ZCKJ9 0.310
(0.683)
ISO M20 x 1.5 ZCKJ9H29 0.310
(0.683)
2 step
Double-pole 2 C/O
staggered
snap action
(XESP2031)
—
1/2" NPT ZCKJ4 0.310
(0.683)
ISO M20 x 1.5 ZCKJ4H29 0.310
(0.683)
Plug-in body
1 step
Single-pole 1 C/O
snap action —
1/2" NPT ZCKJ11 0.300
(0.661)
ISO M20 x 1.5 ZCKJ11H29 0.300
(0.661)
Double-pole 2 C/O
simultaneous
snap action
—
1/2" NPT ZCKJ21 0.300
(0.661)
ISO M20 x 1.5 ZCKJ21H29 0.300
(0.661)
2 step
Double-pole 2 C/O
staggered
snap action
—
1/2" NPT ZCKJ41 0.300
(0.661)
ISO M20 x 1.5 ZCKJ41H29 0.300
(0.661)
Body with contacts—With spring return rotary head (without operating lever)
Type Contact block Function
diagram
Positive
operation
(1)
Cable entry Catalog
number
Weight
kg (lb)
Fixed non-plug-in body
Neutral position
1 from the left and
1 from the right
Double-pole 2 C/O
staggered
snap action
—
1/2" NPT ZCKJ4046 0.455
(1.003)
ISO M20 x 1.5 ZCKJ4046H29 0.455
(1.003)
Plug-in body
Neutral position
1 from the left and
1 from the right
Double-pole 2 C/O
staggered
snap action
—
1/2" NPT ZCKJ41046 0.465
(1.025)
ISO M20 x 1.5 ZCKJ41046H29 0.465
(1.025)
1. : Operating head able to guarantee positive opening operation, when properly mounted and using a conforming operator.
The positive opening feature requires additional travel past the trip point. See the contact function diagrams.
ZCKJ1
ZCKJ11
22 21
13
14
22 21
23
24
12 11
13
14
22 21
13
14
22 21
14 13
12 11
22 21
1314
24 23
12 11
22 21
22 21
23
24
12 11
13
14
12 11
13
14
22 21
23
24
12 11
13
14
22 21
23
24
12 11
13
14
ZCKJ4046
22 21
23
24
12 11
13
14
22 21
23
24
12 11
13
14
Setup:
page 122
Dimensions:
page 124
115
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies with 1/2" NPT Cable Entry
Low-Temperature Applications (–40 °F / –40 °C)
Plunger heads
Type of operator Compatible
bodies
Max. actuation
speed
Positive
operation (1)
Catalog
number
Weight
kg (lb)
For actuation on end
End plunger
metal ZCKJ•, ZCKJ•• 0.5 m/s (1.64 ft/s) ZCKE616 0.140
(0.309)
Side plunger
metal
ZCKJ•, ZCKJ••,
except ZCKJ4 and
J41
0.5 m/s (1.64 ft/s) ZCKE636 0.200
(0.441)
For actuation by 30° cam
End roller plunger
steel ZCKJ•, ZCKJ•• 1 m/s (3.28 ft/s) ZCKE626 0.155
(0.342)
End reinforced roller plunger
steel
ZCKJ•,
ZCKJ•• 1 m/s (3.28 ft/s) ZCKE676 0.155
(0.342)
Side roller
plunger
steel
Horizontal
ZCKJ•, ZCKJ••,
except ZCKJ4 and
J41
0.6 m/s (1.97 ft/s) ZCKE646 0.205
(0.452)
Ve r tic al
ZCKJ•, ZCKJ••,
except ZCKJ4 and
J41
0.6 m/s (1.97 ft/s) ZCKE656 0.205
(0.452)
Roller lever
plunger
(1 direction
of actuation)
Thermoplastic ZCKJ•, ZCKJ•• 1.5 m/s (4.92 ft/s) ZCKE216 0.185
(0.408)
Steel ZCKJ•, ZCKJ•• 1.5 m/s (4.92 ft/s) ZCKE236 0.195
(0.430)
Rotary heads
(without operating lever)
Type Compatible
bodies
Max. actuation
speed
Positive
operation
(1)
Catalog
number
Weight
kg (lb)
Spring return,
actuation from left AND right or from
left OR right
(see page 22)
ZCKJ•, ZCKJ•• 1.5 m/s (4.92 ft/s)
by 30° cam ZCKE056 0.165
(0.364)
Stay put,
actuation from left AND right
(see page 22)
ZCKJ1, J11
ZCKJ2, J21 1.5 m/s (4.92 ft/s) — ZCKE096 0.190
(0.419)
Multi-directional heads
Type of operator Compatible
bodies
Max. actuation
speed
Positive
operation
(1)
Catalog
number
Weight
kg (lb)
For actuation by any moving part
“Cat's whisker”
ZCKJ•, ZCKJ••,
except ZCKJ4 and
ZCKJ41
1 m/s (3.28 ft/s)
in any direction —ZCKE066 0.115
(0.254)
Spring rod lever
ZCKJ•, ZCKJ••,
except ZCKJ4 and
ZCKJ41
0.5 m/s (1.64 ft/s)
in any direction —ZCKE086 0.125
(0.276)
1. : Operating head able to guarantee positive opening operation, when properly mounted and using a conforming operator. The
positive opening feature requires additional travel past the trip point. See the contact function diagrams.
ZCKE616 ZCKE636
ZCKE646 ZCKE656
ZCKE086ZCKE066
ZCKE096ZCKE056
ZCKE216 ZCKE236
ZCKE626 ZCKE676
Setup:
page 122
Dimensions:
page 124
116
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies with 1/2" NPT Cable Entry
Low-Temperature Applications (–40 °F / –40 °C)
Operating levers for rotary heads
Description Positive
operation (1)
Catalog
number
Weight
kg (lb)
For actuation by 30° cam
Roller lever
(2)
Thermoplastic ZCKY11 0.025
(0.055)
Steel ZCKY13 0.035
(0.077)
Steel, ball bearing mounted ZCKY14 0.030
(0.066)
Variable length roller
lever (3)
Thermoplastic — ZCKY41 0.030
(0.066)
Steel — ZCKY43 0.040
(0.088)
For actuation by any moving part
Square rod (2) U 3 mm (0.12 in.) steel,
L = 125 mm (4.92 in.) —ZCKY51 0.025
(0.055)
Round rod (2)
Ø 3 mm (0.12 in.) steel,
L = 125 mm (4.92 in.) —ZCKY53 0.025
(0.055)
Ø 3 mm (0.12 in.) glass fibre,
L = 125 mm (4.92 in.) —ZCKY52 0.020
(0.044)
Ø 6 mm (0.24 in.) thermoplastic,
L = 200 mm (7.87 in.) —ZCKY59 0.030
(0.066)
Spring lever (3) —ZCKY81 0.020
(0.044)
Spring metal rod lever (3) —ZCKY91 0.025
(0.055)
For actuation by specific cam (for operation with ZCK-E096 head)
Forked arm and
rollers (2)
thermoplastic
1 track — ZCKY71 0.035
(0.077)
2 track — ZCKY61 0.035
(0.077)
2- or double-pole contact blocks
Type Function diagram For body
type
Positive
operation (1)
Catalog
number
Weight
kg (lb)
1 N/C + 1 N/O
snap action ZCKJ1 XE2SP2151 0.020
(0.044)
1 N/C + 1 N/O
break before make
slow break
ZCKJ5 XE2NP2151 0.020
(0.044)
2 C/O
simultaneous
snap action
ZCKJ2 — XESP2021 0.045
(0.099)
2 C/O
staggered
snap action
ZCKJ4 — XESP2031 0.045
(0.099)
1 N/O + 1 N/C
make before break
slow break
ZCKJ6 XE2NP2161 0.020
(0.044)
1 N/C + 1 N/C
simultaneous
slow break
ZCKJ7 XE2NP2141 0.020
(0.044)
1 N/O + 1 N/O
simultaneous
slow break
ZCKJ8 — XE2NP2131 0.020
(0.044)
1 N/C + 1 N/C
snap action ZCKJ9 XE2SP2141 0.020
(0.044)
1. : Operating lever able to guarantee positive opening operation, when properly mounted and using a conforming
operator, or N/C contact with positive opening operation. The positive opening feature requires additional travel past the trip
point. See the contact function diagrams.
2. Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting or clamp.
3. Adjustable throughout 360° in 5° steps.
Setup:
page 122
Dimensions:
page 124
ZCKY4•
ZCKY81
ZCKY51
ZCKY61
XE2S P21•1 XE2N P21•1
XESP20•1
ZCKY91
ZCKY71
ZCKY5• ZCKY59
ZCKY1•
22 21
13
14
22 21
13
14
22 21
23
24
12 11
13
14
22 21
23
24
12 11
13
14
22 21
14 13
12 11
22 21
1314
24 23
12 11
22 21
117
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies with 1/2" NPT Cable Entry
High-Temperature Applications (+248 °F /+120 °C)
Body with contacts—For plunger or rotary head
Type Contact block Function
diagram
Positive
operation
(1)
Cable entry Catalog
number
Weight
kg (lb)
Fixed body
1 step
2-pole 1 N/C + 1 N/O
snap action
(XE2SP2151)
1/2" NPT ZCKJ1 0.310
(0.683)
ISO M20 x 1.5 ZCKJ1H29 0.310
(0.683)
Double-pole 2 C/O
simultaneous
snap action
(XESP20215)
—
1/2" NPT ZCKJ25 0.310
(0.683)
ISO M20 x 1.5 ZCKJ25H29 0.310
(0.683)
2-pole 1 N/C + 1 N/O
break before make
slow break
(XE2NP2151)
1/2" NPT ZCKJ5 0.310
(0.683)
ISO M20 x 1.5 ZCKJ5H29 0.310
(0.683)
2-pole 1 N/O + 1 N/C
make before break
slow break
(XE2NP2161)
1/2" NPT ZCKJ6 0.310
(0.683)
ISO M20 x 1.5 ZCKJ6H29 0.310
(0.683)
2-pole 1 N/C + 1 N/C
simultaneous
slow break
(XE2NP2141)
1/2" NPT ZCKJ7 0.310
(0.683)
ISO M20 x 1.5 ZCKJ7H29 0.310
(0.683)
2-pole 1 N/O + 1 N/O
simultaneous
slow break
(XE2NP2131)
—
1/2" NPT ZCKJ8 0.310
(0.683)
ISO M20 x 1.5 ZCKJ8H29 0.310
(0.683)
2-pole 1 N/C + 1 N/C
snap action
(XE2SP2141)
1/2" NPT ZCKJ9 0.310
(0.683)
ISO M20 x 1.5 ZCKJ9H29 0.310
(0.683)
2 step
Double-pole 2 C/O
break before make
snap action
(XESP20315)
—
1/2" NPT ZCKJ45 0.310
(0.683)
ISO M20 x 1.5 ZCKJ45H29 0.310
(0.683)
Plug-in body
1 step
Single-pole 1 C/O
snap action —
1/2" NPT ZCKJ115 0.300
(0.661)
ISO M20 x 1.5 ZCKJ115H29 0.300
(0.661)
Double-pole 2 C/O
simultaneous
snap action
—
1/2" NPT ZCKJ215 0.300
(0.661)
ISO M20 x 1.5 ZCKJ215H29 0.300
(0.661)
2 step
Double-pole 2 C/O
break before make
snap action
—
1/2" NPT ZCKJ415 0.300
(0.661)
ISO M20 x 1.5 ZCKJ415H29 0.300
(0.661)
Body with contacts—With spring return rotary head (without operating lever)
Type Contact block Function
diagram
Positive
operation
(1)
Cable entry Catalog
number
Weight
kg (lb)
Fixed body
2 step
1 from the left AND
1 from the right
Double-pole 2 C/O
break before make
snap action
—
1/2" NPT ZCKJ4045 0.455
(1.003)
ISO M20 x 1.5 ZCKJ4045H29 0.455
(1.003)
Plug-in body
2 step
1 from the left AND
1 from the right
Double-pole 2 C/O
break before make
snap action
—
1/2" NPT ZCKJ41045 0.465
(1.025)
ISO M20 x 1.5 ZCKJ41045H29 0.465
(1.025)
1. : Operating head able to guarantee positive opening operation, when properly mounted and using a conforming operator. The positive opening
feature requires additional travel past the trip point. See the contact function diagrams.
ZCKJ•
ZCKJ•15
22 21
13
14
22 21
23
24
12 11
13
14
22 21
13
14
22 21
14 13
12 11
22 21
1314
24 23
12 11
22 21
22 21
23
24
12 11
13
14
12 11
13
14
22 21
23
24
12 11
13
14
22 21
23
24
12 11
13
14
ZCKJ4045
22 21
23
24
12 11
13
14
22 21
23
24
12 11
13
14
Setup:
page 122
Dimensions:
page 124
118
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies with 1/2" NPT Cable Entry
High-Temperature Applications (+248 °F /+120 °C)
Plunger heads
Type of operator Compatible bodies
Max.
actuation
speed
Positive
operation
(1)
Catalog
number
Weight
kg (lb)
For actuation on end
End plunger Metal
ZCKJ1, J2, J4,
ZCKJ115, J215, J415,
ZCKJ5, J6, J7, J8, J9
0.5 m/s
(1.64 ft/s) ZCKE615 0.140
(0.309)
Side plunger Metal
ZCKJ1, J2,
ZCKJ115, J215,
ZCKJ5, J6, J7, J8, J9
0.5 m/s
(1.64 ft/s) ZCKE635 0.200
(0.441)
For actuation by 30° cam
End ball bearing plunger Steel
ZCKJ1, J2, J4,
ZCKJ115, J215, J415,
ZCKJ5, J6, J7, J8, J9
0.1 m/s
(0.33 ft/s) ZCKE665 0.150
(0.331)
End roller plunger Steel
ZCKJ1, J2, J4,
ZCKJ115, J215, J415,
ZCKJ5, J6, J7, J8, J9
1 m/s (3.28 ft/s) ZCKE625 0.155
(0.342)
End reinforced roller
plunger Steel
ZCKJ1, J2, J4,
ZCKJ115, J215, J415,
ZCKJ5, J6, J7, J8, J9
1 m/s (3.28 ft/s) ZCKE675 0.155
(0.342)
Side roller plunger
Steel
Horizontal
ZCKJ1, J2,
ZCKJ115, J215,
ZCKJ5, J6, J7, J8, J9
0.6 m/s
(1.97 ft/s) ZCKE645 0.205
(0.452)
Steel
Ver ti ca l
ZCKJ1, J2,
ZCKJ115, J215,
ZCKJ5, J6, J7, J8, J9
0.6 m/s
(1.97 ft/s) ZCKE655 0.205
(0.452)
Roller lever plunger
(1 direction of actuation)
Steel
ZCKJ1, J2, J4,
ZCKJ115, J215, J415,
ZCKJ5, J6, J7, J8, J9
1.5 m/s
(4.92 ft/s) ZCKE235 0.195
(0.430)
Thermoplastic
ZCKJ1, J2, J4,
ZCKJ115, J215, J415,
ZCKJ5, J6, J7, J8, J9
1.5 m/s
(4.92 ft/s) ZCKE215 0.185
(0.408)
Rotary heads
(without operating lever)
Type Compatible bodies
Max.
actuation
speed
Positive
operation
(1)
Catalog
number
Weight
kg (lb)
Spring return,
actuation from left AND right or from left OR right
(see page 22)
ZCKJ1, J2, J4,
ZCKJ115, J215,
ZCKJ415,
ZCKJ5, J6, J7, J8, J9
1.5 m/s
(4.92 ft/s)
by 30° cam
ZCKE055 0.165
(0.364)
Stay put,
actuation from left AND right (see page 22
ZCKJ1, J2,
ZCKJ115, J215
0.5 m/s
(1.64 ft/s) —ZCKE095 0.190
(0.419)
Multi-directional heads
Type of operator Compatible bodies
Max.
actuation
speed
Positive
operation
(1)
Catalog
number
Weight
kg (lb)
For actuation by any moving part
“Cat's whisker”
ZCKJ1, J2,
ZCKJ115, J215,
ZCKJ5, J6, J7, J8, J9
1 m/s (3.28 ft/s)
in any direction —ZCKE065 0.115
(0.254)
Spring rod lever
ZCKJ1, J2,
ZCKJ115, J215,
ZCKJ5, J6, J7, J8, J9
0.5 m/s
(1.64 ft/s)
in any direction
—ZCKE085 0.125
(0.276)
1. : Operating head able to guarantee positive opening operation, when properly mounted and using a conforming operator.
The positive opening feature requires additional travel past the trip point. See the contact function diagrams.
ZCKE615 ZCKE635
ZCKE645
ZCKE655
ZCKE085ZCKE065
ZCKE095ZCKE055
ZCKE235
ZCKE625
ZCKE675
ZCKE665
S
e
t
up:
page 122
Di
mens
i
ons:
page 124
119
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies with 1/2" NPT Cable Entry
High-Temperature Applications (+248 °F /+120 °C)
Operating levers for rotary heads
Description Positive
operation (1)
Catalog
number
Weight
kg (lb)
For actuation by 30° cam
Roller lever (2)
Thermoplastic ZCKY115 0.025 (0.055)
Steel ZCKY13 0.035 (0.077)
Steel, ball bearing mounted ZCKY14 0.030 (0.066)
Variable length
roller lever (3)
Thermoplastic — ZCKY415 0.030 (0.066)
Steel — ZCKY43 0.040 (0.088)
For actuation by any moving part
Square rod (2) U 3 mm (0.12 in.) Steel, L = 125 mm (4.92 in.) — ZCKY51 0.025 (0.055)
Round rod (2) Ø 3 mm (0.12 in.) steel, L = 125 mm (4.92 in.) — ZCKY53 0.025 (0.055)
Ø 3 mm (0.12 in.) glass fibre, L = 125 mm (4.92 in.) — ZCKY52 0.020 (0.044)
For actuation by specific cam (for operation with ZCK-E095 head only)
Forked arm and
rollers (2)
thermoplastiic
1 track — ZCKY715 0.035 (0.077)
2 track — ZCKY615 0.035 (0.077)
2- or double-pole contact blocks
Type of operator Function diagram For body
type
Positive
operation
(1)
Catalog
number
Weight
kg (lb)
1 N/C + 1 N/O
snap action ZCKJ1 XE2SP2151 0.020 (0.044)
1 N/C + 1 N/O
break before
make
slow break
ZCKJ5 XE2NP2151 0.020 (0.044)
2 C/O
simultaneous
snap action
ZCKJ25 — XESP20215 0.045 (0.099)
2 C/O staggered
snap action ZCKJ45 — XESP20315 0.045 (0.099)
1 N/O + 1 N/C
make before
break
slow break
ZCKJ6 XE2NP2161 0.020 (0.044)
1 N/C + 1 N/C
simultaneous
slow break
ZCKJ7 XE2NP2141 0.020 (0.044)
1 N/O + 1 N/O
simultaneous
slow break
ZCKJ8 — XE2NP2131 0.020 (0.044)
1 N/C + 1 N/C
snap action ZCKJ9 XE2SP2141 0.020 (0.044)
1. : Operating head able to guarantee positive opening operation, when properly mounted and using a conforming operator.
The positive opening feature requires additional travel past the trip point. See the contact function diagrams.
2. Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting or clamp.
3. Adjustable throughout 360° in 5° steps.
ZCKY43
ZCKY51
ZCKY615
XE2S P21•1 XE2N P21•1
XESP20•15
ZCKY715
ZCKY5•
ZCKY1•
22 21
13
14
22 21
13
14
22 21
23
24
12 11
13
14
22 21
23
24
12 11
13
14
22 21
14 13
12 11
22 21
1314
24 23
12 11
22 21
Setup:
page 122
Dimensions:
page 124
120
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies—Components
Contact blocks
Type of contact Function diagram For bodies Positive
operation (1) Catalog number Weight
kg (lb)
2-pole contact
N/C + N/O
snap action
ZCKJ1
ZCKJ1D XE2S P2151 0.020 (0.044)
N/C + N/O
break before make,
slow break
ZCKJ5
ZCKJ5D XE2N P2151 0.020 (0.044)
2 C/O
simultaneous,
snap action
ZCKJ2 — XES P2021 0.045 (0.099)
2 C/O
staggered,
snap action
ZCKJ4 — XES P2031 0.045 (0.099)
N/O + N/C
make before break,
slow break
ZCKJ6
ZCKJ6D XE2N P2161 0.020 (0.044)
N/C + N/C
simultaneous,
slow break
ZCKJ7
ZCKJ7D XE2N P2141 0.020 (0.044)
N/O + N/O
simultaneous,
slow break
ZCKJ8
ZCKJ8D —XE2N P2131 0.020 (0.044)
N/C + N/C
snap action ZCKJ9 XE2S P2141 0.020 (0.044)
3-pole contact
N/C + N/O + N/O
snap action ZCKJD31 XE3S P2151 0.035 (0.077)
N/C + N/C + N/O
snap action ZCKJD39 XE3S P2141 0.035 (0.077)
N/C + N/C + N/O
break before make,
slow break
ZCKJD37 XE3N P2141 0.035 (0.077)
N/C + N/O + N/O
break before make,
slow break
ZCKJD35 XE3N P2151 0.035 (0.077)
1. : N/C contact with positive opening operation, when properly mounted and using a conforming operator.
22 21
13
14
22 21
13
14
22 21
23
24
12 11
13
14
22 21
23
24
12 11
13
14
22 21
14 13
12 11
22 21
1314
24 23
12 11
22 21
32 31
1314
3334
32 31
22 21
1314
32 31
22 21
1314
22 21
1314
3334
121
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies—Components
Covers + indicator light module
For use with Number and type
of indicators Voltage Catalog number Weight
kg (lb)
Fixed non-plug-in body
1 LED 24 Vc ZCK Z020 0.060
(0.132)
2 LEDs 24 Vc ZCK Z021 0.060
(0.132)
2 neon lights
110/120 Va ZCK Z033 0.060
(0.132)
220/240 Va ZCK Z034 0.060
(0.132)
Plug-in switch-top body with
pilot lights
2 LEDs 24 Vc ZCKJ0121 0.200
(0.441)
2 neon lights
110/120 Va ZCKJ0133 0.200
(0.441)
220/240 Va ZCKJ0134 0.200
(0.441)
Indicator light modules
For use with Number and type
of indicators Voltage Catalog number Weight
kg (lb)
Fixed non-plug-in body
1 LED 24 Vc ZCKJ902 0.030
(0.066)
2 LEDs 24 Vc ZCKJ906 0.030
(0.066)
2 neon lights
110/120 Va ZCKJ903 0.030
(0.066)
220/240 Va ZCKJ904 0.030
(0.066)
Module with resistor for machine diagnostics
For use with Resistor value Catalog number Weight
kg (lb)
Fixed non-plug-in body
(XCKJ1 and ZCKJ1 only) 15 kΩ, 1/4 W ZCKJ82A 0.030
(0.066)
Other versions Covers + indicator light module for other supply voltages.
Please consult your local sales office.
122
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies—Components
Function diagrams (positive operation assured only if the associated sub-assemblies are )
Heads ZCKE61,
E619, E66 with
body
ZCKJ1• ZCKJ2• ZCKJ5• ZCKJ6• ZCKJ7• ZCKJ8•
ZCKJ9 ZCKJD39 ZCKJD37 ZCKJD31 ZCKJD35
Head ZCKE63 with
body
ZCKJ1• ZCKJ2• ZCKJ5• ZCKJ6 ZCKJ7 ZCKJ8
ZCKJ9 ZCKJD39 ZCKJD37 ZCKJD31 ZCKJD35
Heads ZCKE64,
E65 with body
ZCKJ1• ZCKJ2• ZCKJ5• ZCKJ6 ZCKJ7 ZCKJ8
ZCKJ9 ZCKJD39 ZCKJD37 ZCKJD31 ZCKJD35
Heads ZCKE67,
E629 with body
ZCKJ1• ZCKJ2• ZCKJ5• ZCKJ6 ZCKJ7 ZCKJ8
ZCKJ9 ZCKJD39 ZCKJD37 ZCKJD31 ZCKJD35
Heads ZCKE21,
E23 with body
ZCKJ1• ZCKJ2• ZCKJ5• ZCKJ6 ZCKJ7 ZCKJ8
ZCKJ9 ZCKJD39 ZCKJD37 ZCKJD31 ZCKJD35
Heads ZCKE06,
E08 with body
ZCKJ1• ZCKJ2• ZCKJ5• ZCKJ6 ZCKJ7 ZCKJ8
ZCKJ9 ZCKJD39 ZCKJD37 ZCKJD31 ZCKJD35
ZCKJ4•
Unactuated 1st step 2nd step
Contact operation G contact closed
H contact open
(A) = cam displacement
(P) = positive opening point
2
21-22
13-14
21-22
13-14
0
4,7(P)
0,9
6mm
2
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-240
0,9
6mm
2
06mm
3,2
3,4(P)
21-22
13-14
3,2
6mm2
4,6(P)
21-22
13-14
6mm2
3,4(P)
11-12
21-22
6mm2
13-14
23-24
2
11-12
21-22
11-12
21-22
0
4,7(P)
0,9
6mm
2 4,7(P)
6
mm
13-14
31-32
21-22
21-22
31-32
13-1400,9
3,4(P)
6mm3,2
2
21-22
31-32
13-14
0
2 4,7(P)
6mm
13-14
33-34
21-22
21-22
33-34
13-1400,9
3,4(P)
6mm3,2
2
21-22
33-34
13-14 0
1,5
05,5mm
0,9
4(P)
21-22
13-14
21-22
13-14
1,5
05,5mm
0,9
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24
1,5
21-22
13-14
02,7 5,5mm
2,9(P) 2,7
21-22
13-14
01,5 5,5mm
4,1(P)
21-22
13-14
01,5 5,5mm
2,9(P) 21-22
13-14
01,5 5,5mm
1,5
05,5mm
0,9
4(P)
11-12
21-22
11-12
21-22
1,5 4(P)
5,5mm
13-14
31-32
21-22
21-22
31-32
13-14
00,9
2,9(P)
5,5mm2,7
1,5
21-22
31-32
13-14 0
1,5 4(P)
5,5mm
13-14
33-34
21-22
21-22
33-34
13-1400,9
2,9(P)
5,5mm2,7
1,5
21-22
33-34
13-14
0
2,6(A)
0mm
1,5
6,4(P)
21-22
13-14
21-22
13-14
2,6(A)
0mm
1,5
11-12/21-22
13-14/23-24
11-12/21-22
13-24/23-24
2,6(A)
21-22
13-1404,6 mm
4,7(P) 3,7
21-22
13-14
0mm
5,8(P)
2,6(A)
21-22
13-14
0mm
4,7(P)
2,6(A)
21-22
13-14
0mm
2,6(A)
2,6(A)
0mm
1,5
6,4(P)
11-12
21-22
11-12
21-22
2,6(A) 6,4(P)
mm
13-14
31-32
21-22
21-22
31-32
13-14
1,5
0
mm4,6
0
4,7(P)
2,6(A)
21-22
31-32
13-14
2,6(A) 6,4(P)
mm
13-14
33-34
21-22
21-22
33-34
13-1401,5
0
4,7(P)
mm4,6
2,6(A)
21-22
33-34
13-14
3,2(A)
0mm
1,5
8,1(P)
21-22
13-14
21-22
13-14
3,2(A)
0mm
1,5
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24
3,2(A)
0mm
5,3
5,9(P)
21-22
13-14
5,3(A)
m
m
3,2(A)
8(P)
21-22
13-14
5,9(P)
mm3,2(A)
11-12
21-22
mm3,2(A)
13-14
23-24
3,2 (A)
0mm
1,5
8,1(P)
11-12
21-22
11-12
21-22
8,1(P)
3,2
mm
13-14
31-32
21-22
21-22
31-32
13-1401,5
0mm5,3
3,2 5,9(P)
21-22
31-32
13-14
mm
13-14
33-34
21-22
21-22
33-34
13-1401,5
3,2(A) 8,1(P)
0
5,9(P)
mm5,3
3,2(A)
21-22
33-34
13-14
5(A)
0mm
2,2
11,5(P)
21-22
13-14
21-22
13-14
5(A)
0mm
2,2
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24
5(A)
21-22
13-14
08mm
8,5(P) 8,(A)
21-22
13-14
05(A) mm
11,5(P) 8,5(P)
21-22
13-14
05(A) mm
21-22
13-14
05(A) mm
5(A)
0mm
2,2
11,5(P)
11-12
21-22
11-12
21-22
mm
5(A) 11,5(P)
13-14
31-32
21-22
21-22
31-32
13-1402,2
0mm
8
5(A) 8,5(P)
21-22
31-32
13-14
mm
5(A) 11,5(P)
13-14
33-34
21-22
21-22
33-34
13-1402,2
0mm
8,5(P)
8
5(A)
21-22
33-34
13-14
0
21-22
13-14
21-22
13-14 0
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24
21-22
13-14
0
21-22
13-14
0
21-22
13-14
0
21-22
13-14
0
0
11-12
21-22
11-12
21-22
13-14
31-32
21-22
21-22
31-32
13-140
0
21-22
31-32
13-14 13-14
33-34
21-22
21-22
33-34
13-14
0
0
21-22
33-34
13-14
22 21
23
24
12 11
13
14
12 11
13
14
22 21
23
24
2
12 11
13
14
22 21
23
24
3,5
123
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies—Components
Function diagrams (positive operation assured only if the associated sub-assemblies are )
Head ZCKE05 with body
ZCKJ1• ZCKJ2• ZCKJ5• ZCKJ6 ZCKJ7 ZCKJ8 ZCKJ9
ZCKJD39 ZCKJD37 ZCKJD39 ZCKJD31
ZCKJ4•
Unactuated 1st step, actuated from left or right 2nd step, actuated from left or right
Head ZCKE09 with body
ZCKJ1• ZCKJ2• ZCKJD31 ZCKJD39
ZCKJ404, J4104 (body with head)
Unactuated Actuated from left Actuated from right
Contact operation G contact closed
H contact open (P) = positive opening point
Wiring diagrams
Indicator light modules Module with resistor
1 LED, 24 Vc2 LEDs, 24 Vc2 neon lights, 110/120 or 220/240 Va
1. Orange indicator
2. Green indicator
ZCKJ•D
1–2= N/C
3–4= N/O
5= t
4 A / 24 V max.
0
21-22
13-14
21-22
13-14 0
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24 0
21-22
13-14 21-22
13-14 11-12
21-22 13-14
23-24
0
11-12
21-22
11-12
21-22
13-14
31-32
21-22
21-22
31-32
13-140
0
21-22
31-32
13-14
0
21-22
33-34
13-14 13-14
33-34
21-22
21-22
33-34
13-140
22 21
23
24
12 11
13
14
12 11
13
14
22 21
23
24
12 11
13
14
22 21
23
24
21-22
13-14
0
21-22
13-14
0
0
0
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24
13-14
33-34
21-22
21-22
33-34
13-140
13-14
31-32
21-22
21-22
31-32
13-140
22 21
23
24
12 11
13
14
22 21
23
24
12 11
13
14
12 11
13
14
22 21
23
24
X3X1
(1)
14
21
13
22
+
–
X3
X1
(1)
+
–
X2
(2)
14 13
X3
X1
(1)
X2
(2)
14 13
14 13
15 kΩ
1/4 W
3
4
2
1
1314
22 21
124
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies—Components
Bodies
Non-plug-in
ZCKJ1, J2, J5, J4, J•2•, J•3•, J6, J7, J8, J9
ZCKJ1H29, J2H29, J5H29, J4H29, J•2•H29, J•3•H29,
J6H29, J7H29, J8H29, J9H29
Plug-in
ZCKJ11, J21, J41, J11••
ZCKJ11H29, J21H29, J41H29, J11••H29
Non-plug-in
ZCKJ1D, J5D, J6D, J7D, J8D
Bodies with rotary head mounted
Non-plug-in
ZCKJ404, ZCKJ404H29
Plug-in
ZCKJ4104, ZCKJ4104H29
Plunger heads
ZCKE61 ZCKE619 ZCKE63
ZCKE64 ZCKE65 ZCKE66
ZCKE62, ZCKE67 ZCKE629 ZCKE21, E23
1. 1 tapped entry for 1/2" NPT.
Ø: 2 elongated holes Ø 5.3 x 7.3.
33,5
44
76,5 5
(1)
6,5
60
30
40
=
=
(1)
36
83,5 5
42,5
30
==
60 6,5
6,5
60
30
40
=
=
33,5
44
76,5 5
12
22
60
30
40
=
=
10
(1)
33,5
60
102
44
M6
(1)
36
60
109
42,5
30
==
60 10
22
M6
17
37
17
49,5
10
20
52,3
5
10
20
63,6
5
10
20
63,6
41
17
17
5
50
17
5
50
7
17
19
61
125
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Metal, Conforming to CENELEC EN 50041
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies—Components
Rotary head ZCKE05 with operating lever
ZCKY11, Y13, Y14 ZCKY41, Y43 ZCKY51, Y52, Y53, Y59
JJ1 K
max K1 Ø
ZCKY81 ZCKY91 ZCKY51 20 49 137 123 U 3
ZCKY52 20 49 137 125 Ø 3
ZCKY53 20 49 137 125 Ø 3
ZCKY59 26.2 48 212 200 Ø 6
Rotary head ZCKE09 with operating lever
ZCKY61 ZCKY71
Multi-directional heads
ZCKE06 ZCKE08
NOTE: Operating lever spindle threaded M6.
63
41
62
541
57
62…107
40…85
57
5,5
44
52
59
J1
K
K1
J
92
114
535
157
179
535
15
56
63
5
68
56 15
56
63
5
68
17
155
17
141
126
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Plastic, Conforming to CENELEC EN 50041
XCKS—Double Insulated
b XCKS
fixed, non-plug-in body with 1 cable entry v With head for linear movement (plunger) operators
Page 128
v With head for rotary movement (lever) operators
Page 128
Environmental characteristics
Conforming to standards Products IEC 60947-5-1, EN 60947-5-1, UL 508, CSA C22-2 n° 14
Machine assemblies IEC 60204-1, EN 60204-1
Approvals UL, CSA, CCC
Protective treatment Version Standard “TC” and “TH”
Ambient air temperature For operation - 25…+70 °C (-13…+158 °F)
For storage - 40…+70 °C (-40…+158 °F)
Vibration resistance Conforming to IEC 60068-2-6 25 gn (10…500 Hz)
Shock resistance Conforming to IEC 60068-2-27 50 gn (11 ms)
Electric shock protection Class II conforming to IEC 61140 and NF C 20-030
Degree of protection IP 65 conforming to IEC 60529; IK 03 conforming to EN 50102
Repeat accuracy 0.05 mm on the tripping points, with 1 million operating cycles for head with end plunger
Cable entry Depending on model Tapped entry for PG 13 conduit thread, or tapped ISO M20 x 1.5, 1/2" NPT with adapter
Materials Body and heads: plastic
561656
561657
561658
561659
561660
561661
127
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Plastic, Conforming to CENELEC EN 50041
XCKS—Double Insulated
Contact block characteristics
Rated operational
characteristics
XE2•P a AC-15; A300 (Ue = 240 V, Ie = 3 A); Ithe = 10 A
c DC-13; Q300 (Ue = 250 V, Ie = 0,27 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
XE3•P a AC-15; B300 (Ue = 240 V, Ie = 1,5 A); Ithe = 6 A
c DC-13; R300 (Ue = 250 V, Ie = 0,1 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
Rated insulation voltage
XE2•P Ui = 500 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
XE3•P Ui = 400 V degree of pollution 3 conforming to IEC 60947-1
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Rated impulse withstand
voltage
XE2•P U imp = 6 kV conforming to IEC 60947-1, IEC 60664
XE3•P U imp = 4 kV conforming to IEC 60947-1, IEC 60664
Positive operation (depending on model) N/C contacts with positive opening operation conforming to IEC 60947-5-1 Appendix K,
EN 60947-5-1
Resistance across terminals y 25 mΩ conforming to IEC 60255-7 category 3
Short-circuit protection XE2•P 10 A cartridge fuse type gG (gl)
XE3•P 6 A cartridge fuse type gG (gl)
Cabling
(screw and captive cable
clamp terminals)
XE2SP21•1 Clamping capacity, min.: 1 x 0.34 mm2, max.: 2 x 1.5 mm2
XE2NP21•1 Clamping capacity, min.: 1 x 0.5 mm
2
, max.: 2 x 2.5 mm
2
XESP3021 Clamping capacity, min.: 1 x 0.75 mm
2
,
max.: 2 x 1.5 mm
2
XE3NP and XE3SP Clamping capacity, min.: 1 x 0.34 mm
2
, max.: 1 x 1 mm
2
or 2 x 0.75 mm
2
Minimum actuation speed XE2SP21•1, XESP3021 and XE3SP: 0.01 m/minute (0.03 ft/minute)
XE2NP21•1 and XE3NP: 6 m/minute (19.68 ft/minute)
Electrical durability
•Conforming to IEC 60947-5-1 Appendix C
•Utilization categories AC-15 and DC-13
•Maximum operating rate: 3600 operating cycles per hour
•Load factor: 0.5
XE2SP21•1, XE2SP2141 XE2NP21•1 XESP3021
a.c. supply
a 50/60 Hz
o inductive circuit
d.c. supply c Power switched in W for 5 million operating
cycles. Power switched in W for 5 million operating cycles. Power switched in W for 5 million operating cycles.
Voltage V 24 48 120 Voltage V 24 48 120 Voltage V 24 48 120
oW10 7 4 oW13 9 7 oW10 7 4
For XE2SP•151 on
a
or
c
, N/C and N/O contacts simultaneously loaded to the values shown with reverse polarity.
XE3SP•••• XE3NP••••
a.c. supply
a 50/60 Hz
o inductive
circuit
d.c. supply c
Power switched in W for 5 million
operating cycles.
Power switched in W for 5 million operating
cycles.
Voltage V 24 48 120 Voltage V 24 48 120
oW32 1 oW432
Millions of operating cycles
Current in A
0,1
0,5
1
5
0,5 1 5 10
110 V
48 V
230/400 V
234
Ithe
24 V
0,5 1 2 3 4 5 10
0,1
0,2
0,5
1
5
2
4
3
Ithe
230 V
12/24/48 V
110 V
Millions of operating cycles
Current in A
Millions of operating cycles
Current in A
0,5 1 2 5 10
0,1
0,5
1
5
2
3
4
230 V 48 V
Ithe
12/24 V
34
110 V
0,1
0,5
1
5
0,5 1 5 10
110 V
48 V
230/400 V
234
Ithe
24 V
Millions of operating cycles
Current in A
Millions of operating cycles
Current in A
0,5 1 2 3 4 5 10
0,1
0,2
0,5
1
5
2
4
3
Ithe
230 V
110 V
12/24/48 V
128
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Plastic, Conforming to CENELEC EN 50041
XCKS—Double Insulated, Complete Switches with 1/2" NPT Adapter Included
Type of head Plunger (mounting by the body) Rotary (mounting by the body)
Form B (1) Form C (1) Form A (1) Form D (1)
Type of operator Metal end plunger Steel roller plunger Thermoplastic roller
lever (4)
Elastomer roller
lever, Ø 50 mm
(1.97 in.) (4)
Variable length
thermoplastic roller
lever (4)
Variable length
elastomer roller lever,
Ø 50 mm (1.97 in.) (4)
Round thermoplastic
rod lever, Ø 6 mm
(0.24 in.) (5) (6)
Catalog numbers (2) (3)
2-pole N/C + N/O
snap action
(XE2S P2151)
XCKS101 XCKS102 XCKS131 XCKS139 XCKS141 XCKS149 XCKS159
2-pole N/C + N/O
break before
make, slow
break
(XE2N P2151)
XCKS501 XCKS502 XCKS531 XCKS539 XCKS541 XCKS549 XCKS559
2-pole N/C + N/C
snap action
(XE2S P2141)
ZCKS9 +
ZCKD01
ZCKS9 +
ZCKD02
ZCKS9 +
ZCKD31
ZCKS9 +
ZCKD39
ZCKS9 +
ZCKD41
ZCKS9 +
ZCKD49
ZCKS9 +
ZCKD59
2-pole N/C + N/C
simultaneous,
slow break
(XE2N P2141)
ZCKS7 +
ZCKD01
ZCKS7 +
ZCKD02
ZCKS7 +
ZCKD31
ZCKS7 +
ZCKD39
ZCKS7 +
ZCKD41
ZCKS7 +
ZCKD49
ZCKS7 +
ZCKD59
3-pole
N/C + N/C +
N/O
snap action
(XE3S P2141)
ZCKSD39 +
ZCKD01
ZCKSD39 +
ZCKD02
ZCKSD39 +
ZCKD31
ZCKSD39 +
ZCKD39
ZCKSD39 +
ZCKD41
ZCKSD39 +
ZCKD49
ZCKSD39 +
ZCKD59
3-pole
N/C + N/C +
N/O
break before
make, slow
break
(XE3N P2141)
ZCKSD37 +
ZCKD01
ZCKSD37 +
ZCKD02
ZCKSD37 +
ZCKD31
ZCKSD37 +
ZCKD39
ZCKSD37 +
ZCKD41
ZCKSD37 +
ZCKD49
ZCKSD37 +
ZCKD59
Weight, kg (lb) 0.095 (0.209) 0.105 (0.231) 0.145 (0.320) 0.150 (0.331) 0.155 (0.342) 0.155 (0.342) 0.150 (0.331)
Contact operation contact closed
contact open
(A) = cam displacement
(P) = positive opening point
N/C contact with positive opening operation, when properly
mounted and using a conforming operator
Characteristics
Switch actuation On end By 30° cam By any moving part
Type of actuation
Maximum actuation speed 0.5 m/s (1.64 ft/s) 1.5 m/s (4.92 ft/s) 1 m/s (3.28 ft/s)
Minimum
force or
torque
For tripping 15 N (3.37 lb) 12 N (2.70 lb) 0.15 N•m (1.33 lb-in)
For positive
opening 45 N (10.12 lb) 36 N (8.09 lb) 0.3 N•m
(2.66 lb-in) ——
Cable entry (3) 1 entry tapped M20 x 1.5 mm for ISO cable entry, clamping capacity 7 to 13 mm (0.28 to 0.51 in.)
1. Form conforming to EN 50041. See page 23.
2. Switches with gold contacts or eyelet type connections: please consult your local sales office.
3. To convert PG 13 to 1/2" NPT, use adapter DE9RA1212. For ISO M20 x 1.5, add H29 to the end of the catalog number. Example: XCKS101 becomes XCKS101H29.
4. Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.
5. Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting.
6. Value taken with actuation by moving part at 100 mm (3.94 in.) from the mounting.
1314
22 21
1,8 4,5(P)
5,5
mm
13-14
21-22
21-22
13-14
0
0,9
3,1(A) 7,8(P)
mm
13-14
21-22
21-22
13-14
0
1,5
23˚ 58˚(P)
80˚
13-14
21-22
21-22
13-14
0
11˚
23˚
80˚
13-14
21-22
21-22
13-14
0
11˚
23˚
80˚
13-14
21-22
21-22
13-14
0
11˚
23˚
80˚
13-14
21-22
21-22
13-14
0
11˚
23˚
80˚
13-14
21-22
21-22
13-14
0
11˚
1314
22 21
1,8 3,2(P)
5,5
mm
13-14
21-22
03
3,1(A) 5,6(P)
mm
13-14
21-22
0 5,2
23˚ 42˚(P)
80˚
13-14
21-22
0 33˚
23˚
80˚
13-14
21-22
0 33˚
23˚
80˚
13-14
21-22
0 33˚
23˚
80˚
13-14
21-22
0 33˚
23˚
80˚
13-14
21-22
0 33˚
12 11
22 21
1,8 4,5(P)
5,5
mm
21-22
11-12
11-12
21-22
0
0,9
21-22
11-12
11-12
21-22
3,1(A) 7,8(P)
mm
0
1,5
21-22
11-12
11-12
21-22
23˚ 58˚(P)
80˚
0
11˚
21-22
11-12
11-12
21-22
23˚
80˚
0
11˚
21-22
11-12
11-12
21-22
23˚
80˚
0
11˚
21-22
11-12
11-12
21-22
23˚
80˚
0
11˚
21-22
11-12
11-12
21-22
23˚
80˚
0
11˚
12 11
22 21
1,8
3,2(P)
5,5
mm
0
21-22
11-12
3,1(A)
5,6(P)
0
21-22
11-12
23˚
42˚(P)
80˚
21-22
11-12
023˚ 80˚
21-22
11-12
023˚ 80˚
21-22
11-12
023˚ 80˚
21-22
11-12
023˚ 80˚
21-22
11-12
0
32 31
22 21
1314
13-14
21-22
31-32
5,5
mm
13-14
0
0,9
1,8 4,5(P)
31-32
21-22
13-14
21-22
31-32
13-14
31-32
21-22
mm
0
1,5
3,1(A) 7,8(P)
13-14
21-22
31-32
13-14
31-32
21-22
80˚
0
11˚
23˚ 58˚(P)
13-14
21-22
31-32
13-14
31-32
21-22
80˚
0
11˚
23˚
13-14
21-22
31-32
13-14
31-32
21-22
80˚
0
11˚
23˚
13-14
21-22
31-32
13-14
31-32
21-22
80˚
0
11˚
23˚
13-14
21-22
31-32
13-14
31-32
21-22
80˚
0
11˚
23˚
32 31
22 21
14 13
5,5
mm
13-14
31-32
03
1,8 3,2(P)
21-22
mm
13-14
31-32
0 5,2
3,1(A) 5,6(P)
21-22
80˚
13-14
31-32
0 33˚
23˚ 42˚(P)
21-22
80˚
13-14
31-32
0 33˚
23˚
21-22
80˚
13-14
31-32
0 33˚
23˚
21-22
80˚
13-14
31-32
0 33˚
23˚
21-22
80˚
13-14
31-32
0 33˚
23˚
21-22
129
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Plastic, Conforming to CENELEC EN 50041
XCKS—Double Insulated, Complete Switches with 1/2" NPT Adapter Included
XCKS•01
ZCKS• + ZCKD01
XCKS•02
ZCKS• + ZCKD02
XCKS•31
ZCKS• + ZCKD31
XCKS•39
ZCKS• + ZCKD39
XCKS•41
ZCKS• + ZCKD41
XCKS•49
ZCKS• + ZCKD49
XCKS•59
ZCKS• + ZCKD59
1. 1 tapped entry for PG 13 conduit thread (convertible to 1/2" NPT using adapter DE9RA1212, included); or
1 tapped entry for ISO M20 x 1.5 conduit thread (with suffix H29 added to the catalog number).
2. Rod Ø 6 mm (0.24 in.), length 200 mm (7.87 in.)
3. 190 max.
4. 212 max.
Ø: 2 elongated holes Ø 5.3 x 7.3.
36
29,5
103
(1)
16
40
30==
60 36,5
116
16
4
36
29,5
(1)
60 49,5
40
30==
60
29,5
129
55
639
(1)
40
30==
60 63
41
60 76,5
54,5
40
30==
65
29,5
142,5
(1)
57
10
57
29,5
117...172
53
645
(1)
60 51,5...106
29,5...84
40
30==
132,5...187,5
58
10
57
29,5
(1)
40
30==
60 67...121,5
45...99,5
98...280
48,5
(2)
57
29,5
(1)
60 (4)
(3)
24
40
30==
130
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Plastic, Conforming to CENELEC EN 50041
XCKS—Double Insulated, Modular
1. For further details, see page 132. For a cable entry tapped ISO M20 x 1.5, add H29 to the catalog number. Example: ZCKS1 becomes ZCKS1H29.
To convert PG 13 to 1/2" NPT, use adapter DE9RA1212. See page 135 for dimensional drawing.
2. Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.
3. Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting.
ZCK D02 ZCK D029ZCK D01 ZCK D019
ZCK D08 ZCK D06
ZCK S1, S5, S6, S7, S9
ZCK S2, S8
ZCK D81 ZCK D91
ZCK D33 ZCK D34ZCK D31
ZCK D39 ZCK D49 ZCK D41
ZCK D54 ZCK D55 ZCK D59
ZCK SD31, SD35, SD37, SD39
Square rod lever,
steel, U 3 (0.12)
L = 125 (4.92) (2)
Round rod lever,
thermoplastic,
Ø 6 (0.24)
L = 200 (7.87) (3)
Round rod lever,
glass fibre,
Ø 3 (0.12)
L = 125 (4.92) (2)
Elastomer
roller lever,
Ø 50 (1.97) (2)
Variable length
thermoplastic
roller lever (2)
Variable length
elastomer roller lever,
Ø 50 (1.97) (2)
Thermoplastic
roller lever (2)
Spring rod Cat’s whisker Spring lever with
thermoplastic end
(2)
Spring-rod lever,
metal (2)
Metal end plunger Steel roller plunger
Metal end plunger
with protective boot
Steel roller plunger
with protective boot
Body with 2-pole contact,
cable entry for PG 13
1 step (1)
Body with 2-pole contact,
cable entry for PG 13
1 step (1)
Steel roller
lever (2)
Steel ball bearing
mounted roller lever (2)
Dimensions: mm (in.)
131
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Plastic, Conforming to CENELEC EN 50041
XCKS—Double Insulated, Modular
1. For further details, see page 132. For a cable entry tapped ISO M20 x 1.5, add H29 to the catalog number. Example: ZCKS1 becomes ZCKS1H29.
To convert PG 13 to 1/2" NPT, use adapter DE9RA1212.
: N/C contact with positive opening operation or head assuring positive opening operation, when properly mounted and using a conforming operator.
2. Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.
3. Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting.
ZCK D05
ZCK Y33 ZCK Y34ZCK Y31
ZCK Y41 ZCK Y43
ZCK Y81 ZCK Y91
ZCK Y59
ZCK S404
ZCK Y49 ZCK Y39
ZCK Y55ZCK Y54
Square rod lever,
steel, U 3 (0.12)
L = 125 (4.92) (3)
Round rod lever,
thermoplastic, Ø 6 (0.24)
L = 200 (7.87) (3)
Round rod lever,
glass fibre,
Ø 3 (0.12)
L = 125 (4.92) (3)
Spring lever with
thermoplastic end (2)
Spring-rod lever,
metal (2)
Variable
length
thermoplastic
roller lever (2)
Variable
length
steel
roller lever (2)
Variable length
elastomer
roller lever,
Ø50
(1.97) (2)
Elastomer
roller lever,
Ø 50 (1.97) (2)
Thermoplastic
roller lever (2)
Steel
roller lever (2)
Steel ball bearing
mounted roller lever (2)
For actuation from
left AND right
or
from left OR right
Body with double-pole 2 C/O
staggered, snap action contact
cable entry for PG 13
2 step, 1 from left and 1 from right (1)
Dimensions: mm (in.)
132
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Plastic, Conforming to CENELEC EN 50041
XCKS—Double Insulated, Modular
Bodies with 2-pole contact
Type With contact
block
Function
diagram
Positive
operation
(1)
Cable entry Catalog number Weight
kg (lb)
1 step
N/C + N/O
snap action
(XE2S P2151)
1/2" NPT ZCKS1 0.080
(0.176)
ISO M20 x 1.5 ZCKS1H29 0.080
(0.176)
2 C/O
simultaneous,
snap action
(XES P3021)
—
1/2" NPT ZCKS2 0.080
(0.176)
ISO M20 x 1.5 ZCKS2H29 0.080
(0.176)
N/C + N/O
break before make,
slow break
(XE2N P2151)
1/2" NPT ZCKS5 0.080
(0.176)
ISO M20 x 1.5 ZCKS5H29 0.080
(0.176)
N/O + N/C
make before make,
slow break
(XE2N P2161)
1/2" NPT ZCKS6 0.080
(0.176)
ISO M20 x 1.5 ZCKS6H29 0.080
(0.176)
N/C + N/C
simultaneous,
slow break
(XE2N P2141)
1/2" NPT ZCKS7 0.080
(0.176)
ISO M20 x 1.5 ZCKS7H29 0.080
(0.176)
N/O + N/O
simultaneous,
slow break
(XE2N P2131)
—
1/2" NPT ZCKS8 0.080
(0.176)
ISO M20 x 1.5 ZCKS8H29 0.080
(0.176)
N/C + N/C
snap action
(XE2S P2141)
1/2" NPT ZCKS9 0.080
(0.176)
ISO M20 x 1.5 ZCKS9H29 0.080
(0.176)
Bodies with double-pole contact and spring return rotary head
Without operating lever
Type With contact
block
Function
diagram
Positive
operation
(1)
Cable entry Catalog number Weight
kg (lb)
2 step
1 from left and
1 from right
2 C/O
staggered,
snap action
—
1/2" NPT ZCKS404 0.150
(0.331)
ISO M20 x 1.5 ZCKS404H29 0.150
(0.331)
Bodies with 3-pole contact and 1 cable entry
Type With contact
block
Function
diagram
Positive
operation
(1)
Cable entry Catalog number Weight
kg (lb)
1 step
N/C + N/O + N/O
snap action
(XE3S P2151)
1/2" NPT ZCKSD31 0.080
(0.176)
ISO M20 x 1.5 ZCKSD31H29 0.080
(0.176)
N/C + N/C + N/O
snap action
(XE3S P2141)
1/2" NPT ZCKSD39 0.080
(0.176)
ISO M20 x 1.5 ZCKSD39H29 0.080
(0.176)
N/C + N/C + N/O
break before make,
slow break
(XE3N P2141)
1/2" NPT ZCKSD37 0.080
(0.176)
ISO M20 x 1.5 ZCKSD37H29 0.080
(0.176)
N/C + N/O + N/O
break before make,
slow break
(XE3N P2151)
1/2" NPT ZCKSD35 0.080
(0.176)
ISO M20 x 1.5 ZCKSD35H29 0.080
(0.176)
1. : N/C contact with positive opening operation or head assuring positive opening operation, when properly mounted and using a
conforming operator.
22 21
13
14
22 21
23
24
12 11
13
14
22 21
13
14
22 21
14 13
12 11
22 21
1314
24 23
12 11
22 21
22 21
23
24
12 11
13
14
32 31
1314
3334
32 31
22 21
1314
32 31
22 21
1314
22 21
1314
3334
133
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Plastic, Conforming to CENELEC EN 50041
XCKS—Double Insulated, Modular
Contact blocks
Type of contact Function diagram For body Positive
operation (1) Catalog number Weight
kg (lb)
2-pole contact
N/C + N/O
snap action
ZCKS1 XE2S P2151 0.020
(0.044)
N/C + N/O
break before make,
slow break
ZCKS5 XE2N P2151 0.020
(0.044)
2 C/O
simultaneous,
snap action
ZCKS2 — XES P3021 0.045
(0.099)
N/O + N/C
make before break,
slow break
ZCKS6 XE2N P2161 0.020
(0.044)
N/C + N/C
simultaneous,
slow break
ZCKS7 XE2N P2141 0.020
(0.044)
N/O + N/O
simultaneous,
slow break
ZCKS8 — XE2N P2131 0.020
(0.044)
N/C + N/C
snap action ZCKS9 XE2S P2141 0.020
(0.044)
3-pole contact
N/C + N/O + N/O
snap action ZCKSD31 XE3S P2151 0.035
(0.077)
N/C + N/C + N/O
snap action ZCKSD39 XE3S P2141 0.035
(0.077)
N/C + N/C + N/O
break before make,
slow break
ZCKSD37 XE3N P2141 0.035
(0.077)
N/C + N/O + N/O
break before make,
slow break
ZCKSD35 XE3N P2151 0.035
(0.077)
1. : N/C contact with positive opening operation or sub-assembly assuring positive opening operation, when properly mounted and
using a conforming operator.
Other versions Gold flashed contacts.
Please consult your local sales office.
1/2" NPT Adapter
Description Catalog number Weight
kg (lb)
PG 13 to 1/2" NPT adapter DE9RA1212
22 21
13
14
22 21
13
14
22 21
23
24
12 11
13
14
22 21
14 13
12 11
22 21
1314
24 23
12 11
22 21
32 31
1314
3334
32 31
22 21
1314
32 31
22 21
1314
22 21
1314
3334
134
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, Plastic, Conforming to CENELEC EN 50041
XCKS—Double Insulated, Modular
Heads ZCKD01,
D109 with body
ZCKS1 ZCKS2 ZCKS5 ZCKS6 ZCKS7 ZCKS8
ZCKS9 ZCKSD39 ZCKSD37 ZCKSD31 ZCKSD35
Heads ZCKD02,
D029 with body
ZCKS1 ZCKS2 ZCKS5 ZCKS6 ZCKS7 ZCKS8
ZCKS9 ZCKSD39 ZCKSD37 ZCKSD31 ZCKSD35
Heads ZCKD31,
D33, D34 with
body
ZCKS1 ZCKS2 ZCKS5 ZCKS6 ZCKS7 ZCKS8
ZCKS9 ZCKSD39 ZCKSD37 ZCKSD31 ZCKSD35
Heads ZCKD39,
D41, D49, D54,
D55, D59, D81,
D91 with body
ZCKS1 ZCKS2 ZCKS5 ZCKS6 ZCKS7 ZCKS8
ZCKS9 ZCKSD39 ZCKSD37 ZCKSD31 ZCKSD35
Heads ZCKD05
(positive
operation only
assured with a
operating
lever) with body
ZCKS1 ZCKS2 ZCKS5 ZCKS6 ZCKS7 ZCKS8
ZCKS9 ZCKSD39 ZCKSD37 ZCKSD31 ZCKSD35
Heads ZCKD06,
D08 with body
ZCKS1 ZCKS2 ZCKS5 ZCKS6 ZCKS7 ZCKS8
ZCKS9 ZCKSD39 ZCKSD37 ZCKSD31 ZCKSD35
ZCKS404 (body
with head)
Unactuated Actuated from left Actuated from right
Contact operation G contact closed H contact open (A) = cam displacement (P) = positive opening point
1,8
05,5mm
0,9
4,5(P)
21-22
13-14
21-22
13-14
1,8
05,5mm
0,9
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24
1,8
0 5,5mm
3
3,2(P)
21-22
13-14
3
5,5mm
1,8
4,4(P)
21-22
13-14
3,2(P)
5,5mm
1,8
11-12
21-22 5,5mm
1,8
13-14
23-24
1,8
05,5mm
0,9
4,5(P)
11-12
21-22
11-12
21-22
1,8 4,5(P)
5,5mm
13-14
31-32
21-22
21-22
31-32
13-14
00,9
3,2(P)
5,5mm3
1,8
21-22
31-32
13-14
0
1,8 4,5(P)
5,5mm
13-14
33-34
21-22
21-22
33-34
13-14
00,9
3,2(P)
5,5mm3
1,8
21-22
33-34
13-14
0
3,1(A)
0mm
1,5
7,8(P)
21-22
13-14
21-22
13-14
3,1(A)
0mm
1,5
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24
3,1(A)
0mm
5,2
5,6(P)
21-22
13-14
3,1
5,2(A) 7,6(P)
21-22
13-14
mm 3,1(A)
5,6(P)
11-12
21-22
mm
5,5mm
3,1(A)
13-14
23-24
3,1(A)
0mm
1,5
7,8(P)
11-12
21-22
11-12
21-22
3,1 7,8(P)
5,5mm
13-14
31-32
21-22
21-22
31-32
13-1401,5
5,6(P)
mm5,2
3,1
21-22
31-32
13-14
0
3,1 7,8(P)
mm
13-14
33-34
21-22
21-22
33-34
13-14
01,5
5,6(P)
mm5,2
3,1
21-22
33-34
13-14
0
0
21-22
13-14
21-22
13-14 0
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24 0
21-22
13-14
21-22
13-14 11-12
21-22
13-14
23-24
0
11-12
21-22
11-12
21-22
23˚ 58˚(P)
80˚
13-14
31-32
21-22
21-22
31-32
13-14
11˚
0
42˚(P)
80˚33˚
0
23˚
21-22
31-32
13-14
23˚ 58˚(P)
80˚
13-14
33-34
21-22
21-22
33-34
13-14
011˚
0
42˚(P)
80˚33˚
23˚
21-22
33-34
13-14
0
21-22
13-14
21-22
13-14
0
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24 0
21-22
13-14 21-22
13-14
11-12
21-22 13-14
23-24
0
11-12
21-22
11-12
21-22
23˚
80˚
13-14
31-32
21-22
21-22
31-32
13-14
011˚
080˚33˚
23˚
21-22
31-32
13-14
23˚
80˚
13-14
33-34
21-22
21-22
33-34
13-14
011˚
080˚33˚
23˚
21-22
33-34
13-14
0
21-22
13-14
21-22
13-14 0
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24 0
21-22
13-14
21-22
13-14 11-12
21-22
13-14
23-24
0
11-12
21-22
11-12
21-22
23˚ 58˚(P)
80˚
13-14
31-32
21-22
21-22
31-32
13-14
11˚
0
42˚(P)
80˚33˚
0
23˚
21-22
31-32
13-14
23˚ 58˚(P)
13-14
33-34
21-22
21-22
33-34
13-14080˚
11˚
0
42˚(P)
80˚33˚
23˚
21-22
33-34
13-14
0
21-22
13-14
21-22
13-14
0
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24 0
21-22
13-14 21-22
13-14
11-12
21-22 13-14
23-24
0
11-12
21-22
11-12
21-22
30˚
80˚
13-14
31-32
21-22
21-22
31-32
13-14
14˚
0
80˚40˚
0
30˚
21-22
31-32
13-14
30˚
13-14
33-34
21-22
21-22
33-34
13-14
014˚
040˚
30˚
21-22
33-34
13-14
22 21
23
24
12 11
13
14
22 21
23
24
12 11
13
14
12 11
13
14
22 21
23
24
135
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, Plastic, Conforming to CENELEC EN 50041
XCKS—Double Insulated, Modular
Plunger heads
ZCKD01 ZCKD019 ZCKD02 ZCKD029
Rotary heads
ZCKD31, D33, D34 ZCKD39 ZCKD41 ZCKD49
ZCKD54, D55, D59 ZCKD81 ZCKD91
ZCK (1) rod (2) (3) (4) (5)
D54 U 3, L = 125 115 max. 137 max. 49 24
D55 Ø 3, L = 125 115 max. 137 max. 49 24
D59 Ø 6, L = 200 190 max. 212 max. 46.5 26.2 NOTE: operating lever spindle threaded M6.
Multi-directional heads Bodies with contacts
ZCKD06 ZCKD08
ZCKS1, S2, S5, S6, S7, S8, S9
ZCKS1H29, S2H29, S5H29,
S6H29, S7H29, S8H29, S9H29
ZCKSD3•, SD3•H29
ZCKS404, S404H29
DE9RA1212 (PG 13 to 1/2" NPT adapter)
1. Tapped entry for 1/2" NPT conduit
2. PG 13 threaded sleeve
1. 1 tapped entry for PG 13 conduit thread (convertible to 1/2" NPT using adapter
DE9RA1212); or 1 tapped entry for ISO M20 x 1.5 conduit thread (with suffix H29
added to the catalog number).
Ø: 2 elongated holes Ø 5.3 x 7.3.
16
36,5
36,5
16
4
16
49,5
49,5
4
16
41
63
6
55
39
60
10
57
65
54,5
76,5
645
53
58
29,5...84
51,5...106
65
10
57
45...99,5
67...121,5
57
(4) (5)
(2)
(3)
(1)
553
113,5
553
179
16
144
16
131
29,5
36
(1)
72,5
30
40
=
=
6,5
60
2xØ5,8
Ø
29,5
57
98,5
(1)
10
32
30
40
=
=
60
M6
Ø
2xØ5,3
21.3(2
)
(1)
25.4
20.4
136
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, For Hoisting, Mechanical Handling, and Conveyer Belt Shift Monitoring
XCR and XCRT
b XCR v With head for rotary movement operators, spring return to off position
1 contact actuation position per direction
Page 138
v With head for rotary movement operators, stay put
1 contact actuation position per direction
Page 138
b XCRT v With head for rotary movement operators, spring return to off position
2 contact actuation positions per direction
1 actuated at 10°, other contact actuated at 18°
Page 140
562248
562249
562250
500779_1
562252
562253
137
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, For Hoisting, Mechanical Handling, and Conveyer Belt Shift Monitoring
XCR and XCRT
Environmental characteristics
Conforming to standards Products IEC/EN 60947-5-1, VDE 0660-200 (CSA C22-2 n° 14 for XCR), CCC (for XCR)
Machine assemblies IEC/EN 60204-1, NF C 79-130
Product certifications Standard version XCRA, B, E, F: CSA A300
Special version XCRA, B, E, F: CSA A300, 1/2" NPT
Protective treatment Standard version “TC”
Ambient air temperature Operation: -25…+70 °C (-13…+158 °F); Storage: -40…+70 °C (-40…+158 °F)
Vibration resistance 9 gn (10…500 Hz)
Shock resistance XCRA, B, E, F: 68 gn; XCRT: 30 gn (18 ms)
Electric shock protection Class I conforming to IEC 60536 and NF C 20-030
Degree of protection XCRA, B, E, F: IP 54 conforming to IEC 60529; IP 545 conforming to NF C 20-010
XCRT: IP 65 conforming to IEC 60529; IP 655 conforming to NF C 20-010
Enclosure Metal, except XCRT315: polyester
Cable entry Tapped entry for PG 13 (PG 13.5) conduit thread
Contact block characteristics
Rated operational characteristics a AC-15; A300 (Ue = 240 V, Ie = 3 A)
c DC-13; Q300 (Ue = 250 V, Ie = 0.27 A), conforming to IEC 60947-5-1 Appendix A, EN 60947-5-1
Rated insulation voltage Ui = 500 V degree of pollution 3 conforming to IEC 60947-1 and VDE 0110, group C conforming to NF C 20-040
Ui = 300 V conforming to UL 508, CSA C22-2 n° 14
Rated impulse withstand voltage U imp = 6 kV conforming to IEC 60947-1, IEC 60664
Positive operation (depending on model) N/C contacts with positive opening operation to IEC 60947-5-1 Section 3, EN 60947-5-1
Resistance across terminals ≤ 25 mΩ conforming to NF C 93-050 method A or IEC 60255-7 category 3
Short-circuit protection 10 A cartridge fuse type gG (gl)
Cabling Screw clamp terminals
XE2SP2151: Clamping capacity, min: 1 x 0.34 mm2, max: 2 x 1.5 mm2
XE2NP2151: Clamping capacity, min: 1 x 0.5 mm2, max: 2 x 2.5 mm2
XCRT contacts: Clamping capacity, min: 1 x 0.5 mm2, max: 2 x 2.5 mm2
Minimum actuation speed XE2SP2151 and XCRT contacts: 0.01 m/minute (0.03 ft/minute),
XE2NP2151: 6 m/minute (19.68 ft/minute)
Electrical durability
Conforming to IEC 60947-5-1 Appendix C
Utilization categories AC-15 and DC-13
Maximum operating rate: 3600 operating cycles per hour
Load factor: 0.5
a.c. supply
a 50/60 Hz
inductive circuit
XE2SP2151 XE2NP2151
XCRT contacts
d.c. supply cVoltage 24 V 48 V 120 V
Power switched in W for 5 million
operating cycles W
XE2SP2151 10 7 4
XE2NP2151 13 9 7
XCRT contacts 10 7 4
For XE2SP2151 on a or c N/C and N/O contacts simultaneously loaded to the values shown with reverse
polarity.
0,1
0,5
1
5
0,5 1 5 10
110 V
48 V
230/400 V
234
Ithe
24 V
Millions of operating cycles
Current in A
0,5 1 2 3 4 5 10
0,1
0,2
0,5
1
5
2
4
3
Ithe
230 V
12/24/48 V
110 V
Millions of operating cycles
Current in A
0,5 1 2 5 10
0,1
0,5
1
5
2
3
4
230 V 48 V
Ithe
12/24 V
34
110 V
Millions of operating cycles
Current in A
138
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, For Hoisting and Material Handling
XCR—Complete Switches with One Cable Entry
Type of head Rotary with spring return to off position Stay put
Type of operator Metal rod, U6 mm
(0.24 in.) Thermoplastic roller lever Large thermoplastic
roller lever
Metal rods, U6 mm (0.24 in.)
crossed or “T” (1)
Maximum displacement 55° in each direction 90° in each direction
1. Crossed rods for XCRE•8, “T” rods for XCRF•7.
Catalog numbers of complete switches (
N/C contact with positive opening operation)
Two 2-pole 1 N/C + 1 N/O
snap action
XE2SP2151
Both contacts operate in each
direction
XCRA11 XCRA12 XCRA15 XCRE18
1 contact operates in each
direction
XCRB11 XCRB12 XCRB15 XCRF17
Two 2-pole 1 N/C + 1 N/O
break before make, slow
break XE2NP2151
Both contacts operate in each
direction
XCRA51 XCRA52 XCRA55 XCRE58
1 contact operates in each
direction
XCRB51 XCRB52 XCRB55 XCRF57
Weight, kg (lb) 1.110 1.145 1.155 1.135
Contact operation contact closed
contact open (P) = positive opening point 1. 1st contact
2. 2nd contact
Complementary characteristics not shown under general characteristics (page 127)
Maximum actuation speed 1.5 m/s (4.92 ft/s)
Minimum torque For tripping 0.45 N•m (3.98 lb-in) 0.60 N•m (5.31 lb-in)
For positive opening 0.75 N•m (6.64 lb-in) 0.70 N•m (6.20 lb-in)
Cable entry
1 entry tapped for PG 13 conduit thread conforming to NF C 68-300 (DIN PG 13.5).
Clamping capacity 9 to 12 mm (0.35 to 0.47 in.).
1/2" NPT with adapter DE9RA1212.
22 21
12
14
22 21
13
14
1st contact 2nd contact
21-22
13-14
21-22
13-14
5 5
0
16
16
55 55
30
30
21-22
13-14
21-22
13-14
(P) (P)
(1)
(2) 21-22
13-14
21-22
13-14
5 5
0
16
16
55 55
30
30
21-22
13-14
21-22
13-14
(P) (P)
(1)
(2) 21-22
13-14
21-22
13-14
5 5
0
16
16
55 55
30
30
21-22
13-14
21-22
13-14
(P) (P)
(1)
(2)
25 25
0
65
65
90 90
75
75
15
21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14
(P)
(P)
(P)
(1)
(2)
5 5
0
20
20
55 55
34
34
21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14
(P) (P)
(1)
(2)
5 5
0
20
20
55 55
34
34
21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14
(P) (P)
(1)
(2)
5 5
0
20
20
55 55
34
34
21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14
(P) (P)
(1
)
(2
)
35 35
0
65 9090 65
7575
21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14
(P) (P)
(1
)
(2
)
22 21
12
14
22 21
13
14
1st contact 2nd contact
21-22
13-14
21-22
13-14 (1)
(2) 21-22
13-14
21-22
13-14 (1
)
(2
)
21-22
13-14
21-22
13-14 (1
)
(2
)
21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14 (1)
(2)
21-22
13-14
21-22
13-14 (1)
(2) 21-22
13-14
21-22
13-14 (1
)
(2
)
21-22
13-14
21-22
13-14 (1)
(2) 21-22
13-14
21-22
13-14
21-22
13-14
21-22
13-14 (1)
(2)
139
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, For Hoisting and Material Handling
XCR—Complete Switches with One Cable Entry
Separate components
Description For
switches Type Catalog
number
Weight
kg (lb)
Rod, U 6 mm (0.24 in.) XCRA
XCRB
L = 200 mm (7.87 in.) XCRZ03 0.020 (0.044)
L = 300 mm (11.81 in.) XCRZ04 0.030 (0.066)
Roller lever
thermoplastic roller
XCRA
XCRB —XCRZ02 0.050 (0.110)
Large roller lever
thermoplastic roller
XCRA
XCRB —XCRZ05 0.090 (0.198)
Quick mounting/
release bracket
XCRA, XCRB
XCRE, XCRF —XCRZ09 0.520 (1.146)
Contact block
(2 contacts) with
mounting plate
XCRA, XCRB
XCRE, XCRF
2-pole 1 N/C + 1 N/O
snap action XCRZ12 0.135 (0.298)
2-pole 1 N/C + 1 N/O
break before make,
slow break
XCRZ15 0.135 (0.298)
Description Application Sold in lots of Unit catalog
number
Weight
kg (lb)
Adapter PG 13.5 to
ISO M20 x 1.5 5DE9RA13520 0.050 (0.110)
Adapter PG 13.5 to
1/2" NPT 5 DE9RA1212 0.050 (0.110)
XCRZ02 XCRZ05
XCRZ09 XCRZ1•
140
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, For Conveyer Belt Shift Monitoring
XCRT—Complete Switches with One Cable Entry and 1/2" NPT Adapter Included
Type of switch Standard For corrosive atmospheres
Features
Zinc alloy enclosure
Colour: industrial blue
Zinc plated steel lever,
spring return to off position
Cam angles: 10° and 18°
Maximum displacement: 90°
Zinc alloy enclosure
Colour: blue
Stainless steel lever,
spring return to off position
Cam angles: 10° and 18°
Maximum displacement: 90°
Glass reinforced polyester enclosure
Colour: grey
Stainless steel lever,
spring return to off position
Cam angles: 10° and 18°
Maximum displacement: 70°
Catalog numbers of complete switches
2 single-pole C/O snap action XCRT115 XCRT215 XCRT315
Weight, kg (lb) 1.170 (2.579) 1.170 (2.579) 1.520 (3.351)
Contact operation contact closed
contact open
Complementary characteristics not shown under general characteristics (page 127)
Minimum tripping torque 1.0 N•m (8.85 lb-in)
Cable entry
1 entry tapped for PG 13 conduit thread conforming to NF C 68-300 (DIN PG 13.5)
Clamping capacity 9 to 12 mm (0.35 to 0.47 in.)
1/2" NPT with adapter DE9RA1212 included
Switch operation
Normal position Fault signalling Stopping of the conveyor belt Maximum rotation
12 11
13
14
1st contact
0
11-12
13-14
11-12
13-14
4 4
1010
90 90 0
11-12
13-14
11-12
13-14
4 4
1010
90 90 0
11-12
13-14
11-12
13-14
4 4
1010
70 70
2nd contact
12 11
13
14
0
44
1818
11-12
13-14
11-12
13-14
90 90 0
44
1818
11-12
13-14
11-12
13-14
90 90 0
44
1818
11-12
13-14
11-12
13-14
70 70
Dimensions:
page 143
141
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, For Conveyer Belt Shift Monitoring
XCRT—Complete Switches with One Cable Entry and 1/2" NPT Adapter Included
Separate components
Description Type For
switches
Catalog
number
Weight
kg (lb)
Roller with lever
Zinc plated steel XCRT115
XCRT215 XCRZ901 0.230 (0.507)
Stainless steel
XCRT115
XCRT215 XCRZ902 0.230 (0.507)
XCRT315 XCRZ903 0.230 (0.507)
Quick mounting/release
bracket —XCRT115
XCRT215 XCRZ09 0.520 (1.146)
Contact block (2 contacts)
with mounting plate
Single-pole C/O
snap action XCRT•15 XCRZ42 0.135 (0.298)
Description Application Sold in
lots of
Unit catalog
number
Weight
kg (lb)
Adapter PG 13.5 to
ISO M20 x 1.5 5DE9RA13520 0.050 (0.110)
Adapter PG 13.5 to
1/2" NPT 5 DE9RA1212 0.050 (0.110)
XCRZ9••
XCRZ42
XCRZ09
142
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, For Hoisting, Mechanical Handling, and Conveyer Belt Shift Monitoring
XCR and XCRT
XCRA11, B11, A51, B51 XCRA12, B12, A52, B52
XCRA15, B15, A55, B55 XCRE18, E58, F17, F57
1. 1 tapped entry for PG 13 conduit thread.
2. Rod length: 200 mm (7.87 in.).
3. Rod + roller length: 160 mm (6.30 in.).
4. Rod length: 300 mm (11.81 in.) for XCRF17 and F57, 200 mm (7.87 in.) for XCR E18 and E58.
Supplementary mounting using 2 adjustable lugs (included with switch) Quick mounting/release bracket XCRZ09
Horizontally positioned Vertically positioned
Ø: 1 elongated hole Ø 6 x 8.
66
53
75
=
=32
95
(2)
85
85
== 75
(1)
18
= =
6
72…60
4
9
53
75
=
=32
95
(3)
85
85
== 75
(1)
18
= =
9
68
53
75
=
=32
95
18
85
78
85
== 75
(1)
= =
102
66
53
75
=
=32
95
(2)
(4)
85
== 75
(1)
18
= =
85
6
53
=
=
5
595
100
11
127
107 =
==
=
36
=
=117
95
137
11
50 50
85=
10 =10
140
Characteristics:
pages 137 and 138
Catalog numbers:
page 138
Operation:
page 138
143
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, For Hoisting, Mechanical Handling, and Conveyer Belt Shift Monitoring
XCR and XCRT
XCRT115, T215
XCRT315
1. 200 max., 83 min.
2. 90° max.
3. 1 tapped entry for PG 13 conduit thread.
4. 70° max.
5. 1 plain entry for PG 13 conduit thread.
Supplementary mounting using 2 adjustable lugs (included with XCRT115 and T215) Quick mounting/release bracket XCRZ09
Horizontally positioned Vertically positioned
Ø: 1 elongated hole Ø 6 x 8.
85
85
== 75
(3)
18
= =
(2) (2)
53
75
=
=32
95
66
80
(1)
==
105
70
==
83
107
80
188
87 85
(5)
146
54
(4) (4)
53
=
=
5
595
100
11
127
107 =
==
=
36
=
=117
95
137
11
50 50
85=
10 =10
140
Characteristics:
pages 137 and 140
Catalog numbers:
page 140
Operation:
page 141
145
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, For Material Handling
XC1AC
Environmental characteristics
Conformity to standards IEC/EN 60947-5-1, IEC 60337-1, VDE 0660-200, CSA C22-2 n° 14
Product certifications Special version CSA 600 V (ac) HD
Protective treatment Version Standard “TC”, special “TH”
Ambient air temperature For operation - 25…+70 °C (-13…+158 °F)
For storage - 40…+70 °C (-40…+158 °F)
Operating position All positions
Vibration resistance 9 gn (10…500 Hz) conforming to IEC 60068-2-6
Shock resistance 95 gn (11 ms) conforming to IEC 60068-2-27
Electric shock protection Class I conforming to IEC 60536 and NF C 20-030
Degree of protection IP 65 conforming to IEC 60529 and NF C 20-010
Mechanical durability 10 million operating cycles
Cable entry 3 tapped entries for PG 13 conduit thread
Contact block characteristics
Conventional thermal current 10 A
Rated insulation voltage Slow break contact blocks a 500 V and c 600 V conforming to IEC 60947-5-1, NF C 20-040
a and c 600 V conforming to CSA C22-2 n° 14
Resistance across terminals ≤ 8 mΩ
Minimum tripping force XC1AC1•1: 33 N (7.42 lb); XC1AC1•6: 23 N (5.17 lb); XC1AC1•7: 29 N (6.52 lb)
Terminal referencing Conforming to CENELEC EN 50013
Short-circuit protection 10 A cartridge fuse type gG (gl)
Electrical durability
Conforming to IEC 60947-5-1 Appendix C
Utilization categories AC-15 and DC-13
Maximum operating rate: 3600 operating cycles/hour
Load factor: 0.5
Slow break contact blocks
a.c. supply
a 50/60 Hz
inductive circuit
Power switched in VA
Voltage V 48 110 230
For 1 million operating cycles 450 900 1900
For 3 million operating cycles 170 350 430
d.c. supply c
inductive circuit
Power switched in W
Voltage V 48 110 230
For 1 million operating cycles 100 100 95
For 3 million operating cycles 35 40 33
146
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, For Material Handling
XC1AC—Complete Switches with Slow-Break Contacts and 1/2" NPT Adapter Included
Type of head Plunger
Type of operator End plunger End ball bearing
plunger Roller lever Offset roller lever Reinforced roller
lever
Roller lever on
needle roller bearing
Catalog numbers of complete switches
Single pole C/O
slow break ZC1AZ11
XC1AC111 XC1AC115 XC1AC116 XC1AC118 XC1AC117 XC1AC119
2-pole N/C + N/O
break before make, slow break ZC1AZ12
XC1AC121 XC1AC125 XC1AC126 XC1AC128 XC1AC127 XC1AC129
2-pole N/O + N/C
make before break, slow break ZC1AZ13
XC1AC131 XC1AC135 XC1AC136 XC1AC138 XC1AC137 XC1AC139
2-pole N/C + N/C
simultaneous, slow break ZC1AZ14
XC1AC141 XC1AC145 XC1AC146 XC1AC148 XC1AC147 XC1AC149
2-pole N/O + N/O
simultaneous, slow break ZC1AZ15
XC1AC151 XC1AC155 XC1AC156 XC1AC158 XC1AC157 XC1AC159
2-pole N/C + N/C
staggered, slow break ZC1AZ16
XC1AC161 XC1AC165 XC1AC166 XC1AC168 XC1AC167 XC1AC169
2-pole N/O + N/O
staggered, slow break ZC1AZ17
XC1AC171 XC1AC175 XC1AC176 XC1AC178 XC1AC177 XC1AC179
Weight, kg (lb) 0.530 (1.168) 0.530 (1.168) 0.595 (1.312) 0.595 (1.312) 0.870 (1.918) 0.870 (1.918)
Contact operation contact closed
contact open
Complementary characteristics not shown under general characteristics (page 137)
Switch actuation On end By 30° cam
Type of actuation
Maximum actuation speed 0.5 m/s
(1.64 ft/s) Direction A: 1 m/s (3.28 ft/s); Direction B: 0.5 m/s (1.64 ft/s) (1)
Cable entry
3 tapped entries for PG 13 (DIN PG 13.5) conduit thread, clamping capacity 9 to 12 mm (0.35 to 0.47 in.)
(2 entries fitted with blanking plug)
1/2" NPT with adapter DE9RA1212
Connection Screw terminals. Clamping capacity: min 1 x 0.5 mm 2, max 1 x 2.5 mm 2
1. For a 45° cam the maximum actuation speed becomes 0.5 m/s (1.64 ft/s) and for a 15° cam, 1 m/s (3.28 ft/s).
1314
12 11
2,1
5,6 mm
9
11-12
13-14
2,1
5,6 mm
9
11-12
13-14
2,3
7,3
12
11-12
13-14
mm
2,3
7,3
12
11-12
13-14
mm
1,6
6,2
11,5
11-12
13-14
mm
1,6
6,2
11,5
11-12
13-14
mm
1314
12 11
6
6,8
7,5
11-12
13-14
mm
6
6,8
7,5
11-12
13-14
mm
7
8
11,5
11-12
13-14
mm
7
8
11,5
11-12
13-14
mm
5,2 11,5
11-12
13-14
6,8 mm
5,2 11,5
11-12
13-14
6,8 mm
1314
12 11
3,5
4,8
8
mm
11-12
13-14
3,5
4,8
8
mm
11-12
13-14
4,5
7
10,5
mm
11-12
13-14
4,5
7
10,5
mm
11-12
13-14
4,4
6,5
11,5
mm
11-12
13-14
4,4
6,5
11,5
mm
11-12
13-14
12 11
22 21
4,3 9,3
mm
11-12
21-22
4,3 9,3
mm
11-12
21-22
5,5 12
11-12
21-22
mm
5,5 12
11-12
21-22
mm
512,5
11-12
21-22
mm
512,5
11-12
21-22
mm
1314
24 23
5,6 9
13-14
23-24
mm
5,6 9
13-14
23-24
mm
7,2 11,5
13-14
23-24
mm
7,2 11,5
13-14
23-24
mm
711,5
13-14
23-24
mm
711,5
13-14
23-24
mm
12 11
22 21
3,7
4,9
9
11-12
21-22
mm
3,7
4,9
9
11-12
21-22
mm
4,5
6,2
12
11-12
21-22
mm
4,5
6,2
12
11-12
21-22
mm
4
5,5
12
11-12
21-22
mm
4
5,5
12
11-12
21-22
mm
1314
24 23
4,8
6
8,5
13-14
23-24
mm
4,8
6
8,5
13-14
23-24
mm
5,8
7,6
12
13-14
23-24
mm
5,8
7,6
12
13-14
23-24
mm
6
7,5
12
13-14
23-24
mm
6
7,5
12
13-14
23-24
mm
BA
147
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, For Material Handling
XC1AC—Complete Switches with Slow-Break Contacts and 1/2" NPT Adapter Included
XC1AC1•1 XC1AC1•5 XC1AC1•6
XC1AC1•8 XC1AC1•7, XC1AC1•9 DE9RA1212
(PG 13 to 1/2" NPT adapter)
1. Tapped entry for 1/2" NPT conduit
2. PG 13 threaded sleeve
1. 3 tapped entries for PG 13 conduit thread or ISO 20 with adapter DE9RA1620.
Ø: 2 elongated holes Ø 6.5 x 10.
(1)
44
20
12
53
=67
77
83 30
113
=(1)
44
20
53
12
=67
77
83 47
130
=(1)
44
5
26
53
12
=67
77
83 56
139
=
37
(1)
44
5
3
53
12
=67
77
83 56
139
=
37
(1)
44
14
20
110
12
=67
77
83 73,5
156,5
=
45,5
5330
Ø28
21.3(2
)
(1)
25.4
20.4
148
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Osiswitch® Classic, For Material Handling
XC1AC—Renewal Parts
Plunger heads
Type of operator Maximum actuation
speed Type of actuation Catalog number Weight
kg (lb)
For actuation on end
End plunger 0.5 m/s (1.64 ft/s) ZC1AC001 0.035
(0.077)
For actuation by 30° cam
End ball bearing
plunger 0.5 m/s (1.64 ft/s) ZC1AC005 0.050
(0.110)
Roller lever
Direction A
Direction B
1 m/s (3.28 ft/s)
0.5 m/s (1.64 ft/s)
ZC1AC006 0.100
(0.220)
Reinforced roller lever
Direction A
Direction B
1 m/s (3.28 ft/s)
0.5 m/s (1.64 ft/s)
ZC1AC007 0.375
(0.827)
Offset roller lever
Direction A
Direction B
1 m/s (3.28 ft/s)
0.5 m/s (1.64 ft/s)
ZC1AC008 0.100
(0.220)
Roller lever on needle
roller bearing
Direction A
Direction B
1 m/s (3.28 ft/s)
0.5 m/s (1.64 ft/s)
ZC1AC009 3.380
(7.452)
Contact blocks
Type of contact Function diagram Catalog number Weight
kg (lb)
C/O, single pole ZC1AZ11 0.040
(0.088)
N/C + N/O break before make ZC1AZ12 0.045
(0.099)
N/O + N/C make before break ZC1AZ13 0.040
(0.088)
N/C + N/C simultaneous ZC1AZ14 0.045
(0.099)
N/O + N/O simultaneous ZC1AZ15 0.045
(0.099)
N/C + N/C staggered ZC1AZ16 0.040
(0.088)
N/O + N/O staggered ZC1AZ17 0.040
(0.088)
Adapter plate
Description Catalog number Weight
kg (lb)
Mounting plate
(For replacing an old version type RN-67522 limit switch with an XC1AC limit switch) ZC1AZ8 3.380
(7.452)
ZC1AC001
ZC1AC005
BA
ZC1AC006
BA
ZC1AC007
ZC1AC009
BA
ZC1AC008
BA
1314
12 11
ZC1AZ1•
1314
12 11
1314
12 11
12 11
22 21
1314
24 23
12 11
22 21
1314
24 23
149
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Osiswitch® Classic, For Material Handling
XC1AC—Renewal Parts
Dimensions
ZC1AC001 ZC1AC005 ZC1-AC006
ZC1AC008 ZC1AC007, AC009 DE9RA1212
(PG 13 to 1/2" NPT adapter)
1. Tapped entry for 1/2" NPT conduit
2. PG 13 threaded sleeve
53
30
20
20
53
47
53
56
37
5
26
53
56
37
5
316
20
110
73,5
45,5
5330
Ø28
21.3(2
)
(1)
25.4
20.4
150
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
151
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Table of Contents
Class 9007 Limit Switches
Snap Action Industrial Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Miniature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Miniature Enclosed Reed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
9007AW Heavy Duty Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
9007C Heavy Duty Industrial—Plug-in Body, Metal . . . . . . . . . . . . . . . . . . . . . . 162
9007C Heavy Duty Industrial—Non-Plug-in Body, Metal . . . . . . . . . . . . . . . . . . 198
9007C Heavy Duty Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
9007T and FT Severe Duty Mill and Foundry Switches . . . . . . . . . . . . . . . . . . . 214
9007T Severe Duty Mill Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
9007FT Severe Duty Foundry Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches . . . . . . 226
Interpretation of Catalog Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
152
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Snap Action Industrial Switches
Class 9007
Industrial Snap Switches and Limit Switches without Enclosures
Industrial Snap Switches have been incorporated in many Square D® products such as timers,
specialty push buttons, foot switches, operating mechanisms, door interlocks, motor control centers,
position switches, and many other control products.
•Recommended Actuator—An adjustable actuator is recommended. If a non-adjustable actuator is used,
a resilient type or a mechanical stop should be used to prevent bottoming of button mechanism.
•Adjustable Actuator Overtravel—Minimum recommended overtravel in both trip and reset directions is 0.015 in. (0.38 mm).
•Non-Adjustable Actuator Total Travel—Maximum differential limit plus 0.030 in. (0.76 mm). Example: 0.076 in. (1.9 mm) for Type AO2.
•Non-Adjustable Actuator Total Travel—Fully retracted—from mounting surface, at least 0.139 in. (3.5 mm) for Type AO1 and 0.160 in.
(4.0 mm) for Types AO2 and CO3. Fully engaged—from mounting surface, at least 0.061 in. (1.5 mm) but not closer than 0.045 in. (1.1 mm).
Quick Make and Break
Type of
Operator
Contact
Arrangement kType Type of
Operator
Contact
Arrangement kType Type of
Operator
Contact
Arrangement •Type
Basic
Snap Switch
1 N.O.
1 N.C. AO 1
Rigid Roller
Lever Type
2 N.O.
2 N.C.
CB 31 (RH) q
Roller
Plunger Type
Panel Mounting
Non-Oiltight
1 N.O.
1 N.C.
AP 321
1 N.C. AO 1A CB 32 (LH) qAP 324 j
1 N.O. AO 1B CB 41 q
(without Side Mtg. Bracket) 2 N.O.
2 N.C.
CP 321
1 N.O.
1 N.C.
AO 2 CB 33 (RH) fCP 324 j
AO 6 (Plug-in) CB 34 (LH) f
Operator Only AP 301 t
1 N.C. AO 2A
Rigid Roller
Lever Type
One Way Roller
1 N.O.
1 N.C.
AB 25 (RH) AP 304 j t
1 N.O. AO 2B AB 26 (LH)
Roller
Plunger Type
Panel Mounting
Oiltight
1 N.O.
1 N.C.
AP 323
2 N.O.
2 N.C. CO 3 2 N.O.
2 N.C.
CB 35 (RH) AP 325 j
2 N.O. CO 6 (Plug-in) CB 36 (LH)
2 N.O.
2 N.C.
CP 323
Two S ta ge
2 N.O.
2 N.C.
CO 7 Cabinet
Door Type
1 N.O.
1 N.C. AC 1 CP 325 j
Rigid Roller
Lever Type
1 N.O.
1 N.C.
AB 21 (RH) q2 N.O.
2 N.C. CC 1
Operator Only
AP 303 t
AB 22 (LH) q
Plunger Type
Panel Mounting
1 N.O.
1 N.C. AP 221 AP 305 j t
AB 41 q
(without Side
Mtg. Bracket)
2 N.O.
2 N.C. CP 221
Mushroom
Button Type
Panel Mounting
1 N.O.
1 N.C. AP 222
AB 23 (RH) f
Operator Only AP 201 t
2 N.O.
2 N.C. CP 222
AB 24 (LH) fOperator Only AP 202 t
kSingle-pole snap switches that contain two double-break contact elements (1 N.O. and 1 N.C.) must
be used on circuits of the same polarity. Two-pole snap switches contain two electrically separated
sets of contact elements allowing use on circuits of opposite polarity. Each set contains two double-
break contact elements (1 N.O. and 1 N.C.) that must be used on circuits of the same polarity.
jRoller turned 90° from standard (perpendicular to mounting holes).
qWith 0.22 in. (5.6 mm) width roller.
fWith 0.47 in. (12.0 mm) width roller.
tFor use with Type AO and CO basic switches.
Type AB21
Type AO2
Maximum Current Ratings For Control Contacts—All Types
Switch
Type Contacts
Direct
Opening
Contacts Meet
IEC 60947-5-1
Requirements
AC—50 or 60 Hz DC
AC or DC
Voltage
Inductive
35% Power Factor
Resistive 75%
Power Factor
Voltage
Inductive and Resistive
Make Break Make and
Break
Amperes
Make and Break
Amperes Continuous
Carrying
Amperes
AVA AVA Single
Pole
Double
Pole
AO1, AC
SPDT
Form Z
SPST k
Form X or Y
No
120
240
480
600
40
20
10
8
4800
4800
4800
4800
15
10
6
5
1800
2400
2880
3000
15
10
6
5
125
250
600
—
0.5
0.25
0.05
—
0.25
0.1
—
—
15
15
15
15
AW, AO2
and AO6,
AB, AP
SPDT
Form Z
SPST k
Form X or Y
No
120
240
480
600
40
20
10
8
4800
4800
4800
4800
15
10
6
5
1800
2400
2880
3000
15
10
6
5
125
250
600
—
2.0
0.5
0.1
—
0.5
0.2
0.02
—
15
15
15
15
AW, CO3
and CO6,
CB, CC,
CP
DPDT
Form ZZ
DPST
Form AA or BB
No
120
240
480
600
30
15
7.5
6
3600
3600
3600
3600
3
1.5
0.75
0.6
360
360
360
360
3
1.5
0.75
0.6
125
250
600
—
1.0
0.3
0.1
—
0.2
0.1
—
—
10
10
10
10
Acceptable Wire Size . . . . . . . . . . . . .14–22 AWG
Recommended Terminal Clamp Torque 6–9 lb-in (0.7–1 Nkm) ®
File E42259
CCN NKCR2
File LR25490
Class 3211-03 Marking
153
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Snap Action Industrial Switches
Class 9007
Approximate Dimensions and Operating Data, Types AO, CO, AP, and CP
Class 9007 Type AO, Single-Pole Snap Switch Class 9007 Type CO, Two-Pole Snap Switch
Operating Data, in. (mm) Operating Data, in. (mm)
AO1, 1A, 1B AO2, 2A, 2B CO3 C07
Pre-travel
Differential
Total travel
Operating force
0.057–0.074 (1.4–1.8)
0.015–0.025 (0.6–0.6)
0 .103–0.125 2.6–3.2)
7–11 oz (0.05–0.08 N)
0.057–0.074 (1.4–1.8)
0.035–0.046 (0.9–1.16)
0.103–0.125 (2.6–3.2)
10–14 oz (0.07–0.1 N)
Pre-travel 1st stage
Pre-travel 2nd stage
Differential
Total travel
Operating force
0.057–0.074 (1.4–1.8)
—
0.025–0.046 (0.6–1.16)
0.103–0.125 (2.6–3.2)
7–12 oz (0.05–0.084 N)
0.035–0.060 (0.9–1.5)
0.060–0.085* (1.5–2.1)
0.010–0.020 (0.25–0.50)
—
7–12 oz (0.05–0.084 N)
tSeparation between first and second stage trip points is 0.020–.025 (0.5–0.6).
Note: Shipping weight of Type AO and CO is 0.25 lb (0.11 kg).
2242-D24
Same Polarity
Must Be
B
B
A
A
Terminal Screws
4-#6 Binder head
#6 Mounting Screws
2 Holes for
Surface
Mounting
Dia.
Operating Button
.167 Max.
0.83
21.1
.330
.310
1.03
26.2
R
R
0.25
6.35
0.17
4.3
1.06
27.0
0.19
4.8
2.5
63.5
2.13
54.1
0.25
6.35
0.19
4.8
0.25
6.35 Dia. Operating Button
1.06
27.0
0.83
21.1
0.19
4.8
2.13
54.1
2.5
63.5
.167 Max.
Mounting
Surface 0.31
7.9 1.14
29.0
1B 1A 2A 2B
Pole 1 Pole 2
2 Holes for
#6 Mounting Screws
Dual Dimensions inches
mm
Type AP201, 221, and CP221 Type AP301, 303, 304, 305, 321, 323, 324, 325, and CP321, 323, 324, 325
NOTE: Type AP221 shown. NOTE: Type AP321 shown.
Type Dimension A Type Dimension A
AP221 0.70 (17.8) AP321, 323, 324, 325 0.70 (17.8)
CP221 0.80 (20.3) CP321, 323, 324, 325 0.80 (20.3)
Operating Data Operating Data
AP221 CP221 AP321, 324 AP323, 325 CP321, 324 CP323, 325
Pretravel
Differential
Overtravel
Total travel
Operating force
0.070–0.089 (1.8–2.2)
0.035–0.046 (0.9–1.2)
0.161–0.180 (4.1–4.6)
0.231–0.269 (5.8–6.8)
10–14 oz (0.07–0.1 N)
0.070–0.089 (1.8–2.2)
0.025–0.046 (0.9–1.2)
0.161–0.180 (4.1–4.6)
0.231–0.269 (5.8–6.8)
7–12 oz (0.05–0.08 N)
Pretravel
Differential
Tot a l t r a vel
Operating force
max.
0.060–0.150 (1.5–3.8)
0.035–0.046 (0.9–1.2)
0.200–0.340 (5.1–8.6)
20 oz (0.14 N)
0.060–0.150 (1.5–3.8)
0.035–0.046 (0.9–1.2)
0.200–0.340 (5.1–8.6)
28 oz (0.2 N)
0.060–0.150 (1.5–3.8)
0.025–0.046 (0.9–1.2)
0.200–0.340 (5.1–8.6)
26 oz (0.18 N)
0.060–0.150 (1.5–3.8)
0.035–0.046 (0.9–1.2)
0.200–0.340 (5.1–8.6)
28 oz (0.2 N)
Note: Shipping weight 0.25 lb (0.11 kg).
.414
0.83
21.0
0.39
9.9
A
0.19
4.8
2.13
54.1
thread
0.47" x 32
0.80
20.3
Plunger to mount in
1/2" Dia. Hole in panels
up to 0.38" (9.6mm) thick.
*6-32 Mtg. Screw
0.09
2.3
2.5
63.5
2.20
55.9
0.38
9.6
0.25
6.35
0.19
4.8
2.13
54.1
0.31
7.9
2.5
63.5
0.38
9.6
*
6-32 Mtg. Screw Plunger to mount in
1/2" Dia. Hole in panels
up to 0.38" (9.6mm) thick.
0.25
6.35
thread
0.47" x 32
.414
0.83
21.0
0.39
9.9
2.69
68.3
A
0.09
2.3
0.86
21.8
1.59
4
0.3
0.19
4.8
.192
154
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Snap Action Industrial Switches
Class 9007
Approximate Dimensions and Operating Data, Types AB, CB, AC, and CC
Types AB21 through 24 and CB31 through 34 Types AB25, 26 and CB35, 36
Note: Type CB31 RH mounting shown.
Type AB41 and CB41 same as above except without side mounting plates.
Note: Type CB35 mounting shown.
Type Dimension Type Dimension
A B C A B C
AB21, 22 1.03 (26.2) 0.5 (12.7) 0.22 (5.6) AB25, 26 1.03 (26.2) 0.5 (12.7) 0.22 (5.6)
AB23, 24 1.03 (26.2) 0.5 (12.7) 0.47 (12.0) CB35, 36 1.13 (28.7) 0.59 (15.0) 0.22 (5.6)
AB41 1.03 (26.2) — 0.22 (5.6)
CB31, 32 1.13 (28.7) 0.59 (15.0) 0.22 (5.6)
CB33, 34 1.13 (28.7) 0.59 (15.0) 0.47 (12.0)
CB41 1.13 (28.7) — 0.22 (5.6)
Operating Data Operating Data
Pre-travel 0.16 (4.5) Pre-travel 0.16 (4.5)
Differential 0.08 (2.0) Differential 0.08 (2.0)
Overtravel 0.06 (1.5) Overtravel 0.06 (1.5)
Total travel 0.22 (5.6) Total travel 0.22 (5.6)
Operating force 8 oz (0.23 kg) Operating force 8 oz (0.23 kg)
Note: Shipping weight 0.25 lb (0.11 kg).
Provisions for
#6 Mtg. Screws
Initial Position
0.5
12.7
Dia.
1.41
35.8
0.53
13.4
A
B
0.53
13.4 0.19
4.8
0.19
4.8
2.13
54.1
2.5
63.5
0.41
10.4
0.83
21.0
0.95
24.1
C
Dia.
0.41
10.4
Initial Position
Provisions for
#6 Mtg. Screws
0.19
4.8
0.19
4.8
2.5
63.5
2.13
54.1
A
B
0.5
12.7
0.83
21.0
0.95
24.1
1.91
48.5
0.53
13.4
0.56
14.2
.240
Types AC1 and CC1
Dimensions Operating Data
AC1 CC1
Pre-travel 0.16 (4.5) 0.16 (4.5)
Differential 0.05 (1.3) 0.07 (1.8)
Overtravel 0.09 (2.3) 0.09 (2.3)
Total travel 0.25 (6.4) 0.25 (6.4)
Operating force 8 oz (0.23 kg) 8 oz (0.23 kg)
Note: Type AC1 shown.
Type Dimension
A B
AC1 1.91 (48.5) 1.5 (38.1)
CC1 2 (50.8) 1.59 (40.4
Note: Shipping weight 0.25 lb (0.11 kg).
0.83
21.1
0.41
10.5
(2) Holes for 10
Mtg. Screws
0.19
4.8
0.19
4.8
1
3.5
88.9 3.88
98.5 .015
.005
0.41
10.4
B
A
Dual Dimensions inches
mm
155
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Miniature
Class 9007 Type MS and ML
Description
Mini-Switch (MS) miniature switches meet the need for very small, enclosed switches with
environmental sealing. A full range of styles are available, including top push plunger, parallel
roller plunger, cross roller plunger, rotary lever, and omnidirectional whisker. Factory pre-
wiring with industrial grade cable (type SJTO) eliminates the need to remove the cover to wire
the switch. Bottom- or side-entrance cable connection is available.
Housings are rugged diecast zinc construction. Excellent sealing is achieved with
an epoxy compound encapsulation of the electrical cable connections and switch housing.
AViton
® O-ring seal on the plunger keeps liquids from entering the switch cavity.
Features
The heavy-duty, completely encapsulated miniature MS limit switch is intended for difficult
applications such as machine tools, earth moving equipment, and general transportation.
Key features include:
Rotary Head
Conventional rotary limit switches have mounting holes in the base or body of the switch. In
our rotary design, mounting holes are located in the head also. Cycling and stress forces are
transmitted from the shaft in the head directly to the mounting bolts. The strain on the joint
between the body and the head is eliminated. The result is a stronger and more rigid
mounting, less subject to vibration or a weakness in the joint.
Bulkhead Mounted Mini-Switches
The MS housing is designed for multiple switching by gang mounting several switches.
Two mounting holes can be tapped in the top of each switch (except rotary lever) for #8-32
thread bolts. Switches can be readily mounted to any frame or plate by drilling holes through
same to accommodate #8-32 bolts and switch plungers. Both sides of the housing are
counter-bored for surface mounting.
•Symmetrical design and top mounting holes for easy gang mounting of several switches for
multiple switching
•Epoxy encapsulation sealing the pre-wired heavy duty #18 AWG SJTO cable and protecting
against temporary submersion
•Single-pole double-throw (SPDT) Form C or Form Z, 1 N.O. + 1 N.C. contact
•Fine rotary lever adjustment •Stainless steel rollers
•Compact diecast zinc housing •UL Listed and CSA Certified
•NEMA Type 6P and IP67 rated •CE Marking
•10 ampere continuous current rating •Standard temperature range:
-40 to +220 °F (-40 to +104 °C)
•Gold contacts for low level logic switching
Options
•Gold crosspoint contacts •Yellow or gray SJTO cable
•Double-break contacts (Type ML only) •4- or 5-pin micro-connectors, AC and DC
•Side-entrance cable or connectors •#16 AWG SJTO cable
•Low force (top plunger models only) •Tapped 8-32 holes on top of housing
Shown with Standard
Bottom Entrance Cable
Shown with
4-Pin Micro-Connector
®
®
File E42259
CCN NKCR
File LR 25490
Class 3211 03
Marking
156
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Miniature
Class 9007 Types MS and ML
General Specifications Type MS Circuit—
Form C
Electrical Ratings/SPDT
Temperature range
-40 to +220 °F (-40 to +104 °C)
The minimum temperatures listed are
based on the absence of freezing
moisture or water.
Silver Contacts Gold Contacts
1 N.O.—1 N.C. Voltage Make Break
100 mA @
125 Vac
30 mA
28 Vdc
120 AC 60 A 6 A
Enclosure rating NEMA Types 1, 2, 4, 6, 6P, 12, 13, IP67 240 AC 30 A 3 A
Vibration resistance 10G (75–1200 Hz) 10.0 Amperes Continuous
Shock resistance 35G DC Contact Rating: 5 A
(Resistance), 28 Vdc
Cable #18 AWG SJTO
Contact Characteristics Type ML Circuit—
Form Z
Electrical Rating/SPDT-DB
Rated thermal current 10 A (standard) Silver Contacts
1 N.O.—1 N.C. Voltage Make Break
Rated insulation voltage 300 Vac and Vdc
(standard)
120 AC 60 A 6 A
240 AC 30 A 3 A
Gold contact switching ratings 0.1 A, 24 Vdc; 0.24 VA 10.0 Amperes, Continuous
DC Contact Rating: 5 A (Res), 28 Vdc
Shown with Side-Entrance Cable
•0.98 in. (25 mm) Mounting Hole Centers
•3 ft (0.9 m) Cable, Standard
•For other available lengths, and for a list of
options, see page 158.
Description / Functional Diagrams
Top Plunger
MS ML MS ML MS ML MS ML
Top plunger Bushing mounted—top plunger Adjustable top plunger
Operating Force/Torque 80 oz (0.6 N)
Contact SPDT
Form Form C Form Z Form C Form Z Form C Form Z
Contact Type Silver MS01S0100 ML01S0100 MS06S0100 ML06S0100 MS09S0100 ML09S0100
Gold MS01G0100 —MS06G0100 —MS09G0100 —
Parallel roller plunger
MS ML MS ML MS ML
Parallel roller plunger Bushing mounted—parallel roller plunger
Operating Force/Torque 80 oz (0.6 N)
Contact SPDT
Form Form CForm ZForm CForm Z
Contact Type Silver MS02S0100 ML02S0100 MS07S0100 ML07S0100
Gold MS02G0100 —MS07G0100 —
Cross roller plunger
MS ML MS ML MS ML
Cross roller plunger Bushing mounted—cross roller plunger
Operating Force/Torque 80 oz (0.6 N)
Contact SPDT
Form Form CForm Z Form CForm Z
Contact Type Silver MS03S0100 ML03S0100 MS08S0100 ML08S0100
Gold MS03G0100 —MS08G0100 —
Rotary lever, CW and CCW Omnidirectional—wire whisker (NEMA Types 1, 2, 12, 13 only)
MS ML MS ML MS
Note: Lever
not included.
Operating Force/Torque 48 oz-in (0.3 N•m) 15 oz-in (0.1 N•m)
Contact SPDT
Form Form C Form Z Form C
Contact Type Silver MS04S0100 ML04S0100 MS05S0100
Gold MS04G0100 —MS05G0100
.004"
max.
.003"
max.
.19"
min.
.19"
min.
0
0
Bk-Rd
Bk-W
Bk-Rd
Bk-W
Bk-Rd
Bk-W
Bk-Rd
Bk-W
0.70" max. 0.80" max.
.004"
max.
.003"
max.
.19"
min.
.19"
min.
0
0
Bk-Rd
Bk-W
Bk-Rd
Bk-W
Bk-Rd
Bk-W
Bk-Rd
Bk-W
0.70" max. 0.80" max.
.004"
max.
.003"
max.
.19"
min.
.19"
min.
0
0
Bk-Rd
Bk-W
Bk-Rd
Bk-W
Bk-Rd
Bk-W
Bk-Rd
Bk-W
0.70" max. 0.80" max.
Bk-Rd
Bk-W
Bk-Rd
Bk-W
5°
35°
Bk-Rd
Bk-W
Bk-Rd
Bk-W
20°
40°
70°
70°
Bk-Rd
Bk-W
Bk-Rd
Bk-W
5°
1
5°
15°
157
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Miniature
Class 9007 Type MS and ML
Note: See the available options on page 158 and add the designator (up to three) to the end of the catalog number, if applicable.
See the example on page 158 for conductor length selection.
Lever Arm Selection
There are many styles of levers to accommodate most industrial applications. The levers are diecast
metal. The standard roller levers are available with nylon rollers and are also available with steel rollers.
See the tables below. Dimensions are given as in. (mm).
Lever tightening torque for mounting the lever on the shaft: minimum 17 lb-in (1.9 N•m).
Description / Functional Diagram
Booted Devices
MS ML MS ML MS ML MS ML
Booted top plunger Booted parallel roller plunger Booted cross roller plunger
Operating Force/Torque 80 oz (0.6 N)
Contact SPDT
Form Form C Form Z Form C Form Z Form C Form Z
Contact Type Silver MS10S0100 ML10S0100 MS12S0100 ML12S0100 MS13S0100 ML13S0100
Gold MS10G0100 —MS12G0100 —MS13G0100 —
Style 7 Levers—0.75 in. (19 mm) diameter, nylon or steel roller
Length Catalog Number
0.25 (6) Wide
Catalog Number
0.5 (13) Wide
Catalog Number
0.75 (19) Wide
Catalog Number
1 (25) Wide
in. mm Nylon Steel Nylon Steel Nylon Steel Nylon Steel
0.875 22.23 7A2N 7A2 7B2N 7B2 7F2N —7J2N —
1.375 34.93 7A3N —7B3N —7F3N —7J3N —
1.5 38.10 7A1N 7A1 7B1N —7F1N —7J1N —
1.75 44.45 7A7N —7B7N —7F7N —7J7N —
2.00 50.8 7A4N —7B4N —7F4N —7J4N —
Style 7X Levers—0.75 in. (19 mm) diameter, nylon or steel roller
Length Catalog Number
0.25 (6) Wide
Catalog Number
0.5 (13) Wide
Catalog Number
0.75 (19) Wide
Catalog Number
1 (25) Wide
in. (mm) Nylon Steel Nylon Steel Nylon Steel Nylon Steel
.875 22.23 7XA2N 7XA2 7XB2N 7XB2 7XF2N —7XJ2N —
1.375 34.93 7XA3N —7XB3N —7XF3N —7XJ3N —
1.5 38.10 7XA1N 7XA1 7XB1N —7XF1N —7XJ1N —
1.75 44.45 7XA7N —7XB7N —7XF7N —7XJ7N —
2.00 50.8 7XA4N —7XB4N —7XF4N —7JX4N —
Specialty Arms and Options
Description Length Diameter Width Catalog Number
Style 7D adjustable length, metal roller 1.38 to 3.38 (35 to 85.8) 0.75 (19) 0.25 (6.35) 7D
Style 7D adjustable length, nylon roller 1.38 to 3.38 (35 to 85.8) 0.75 (19) 0.25 (6.35) 7DN
Style 7S spring nylon rod 6 (152.4) 0.3 (7.6) — 7S
Style 7N nylon rod 5 (127) 0.3 (7.6) — 7N
Corrosion proof (option available with nylon rollers only)—Suffix to add to the end of catalog number S
Lever
.004"
max.
.003"
max.
.19"
min.
.19"
min.
0
0
Bk-Rd
Bk-W
Bk-Rd
Bk-W
Bk-Rd
Bk-W
Bk-Rd
Bk-W
0.70" max. 0.80" max.
158
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Miniature
Class 9007 Type MS and ML
Catalog Number Interpretation and Options
cEx: 9007MS01S0100 with a 9 ft (2.7 m) cable becomes 9007MS01S0300. 9007MS01S0100 with side entrance becomes
9007MS01S0106.
tFor side entry connectors, include 06, then 12, 54, 55, 82, or 84; otherwise the connector will come from bottom of housing. Example of
catalog no. with side entrance connector: 9007MS01S000654. No cable available with 54 and 55. Option 12 is supplied with 3 ft (0.9 m)
of cable.
jDC connectors are rated 3 A, 250 Vac/Vdc.
For Interpretation of the Catalog Number Only
9007 M S 0 1 S 0 1 0 0
Mini Line M
Contact Form Conductor Length Options
S 00No Cable
L 0 1 3 ft (0.9 m) (stranded)
0 2 6 ft (1.8 m)
0 3 9 ft (2.7 m)
Actuator Type 0 4 12 ft (3.7 m)
Top Push Plunger 0 1 0 5 18 ft (5.5 m)
Parallel Roller Plunger 0 2 1 3 33 ft (10 m)
Cross Roller Plunger 0 3 Contact Type
Rotary Lever CW & CCW 0 4 S 10 A Silver Contacts (standard)
Omnidirectional Wire Whisker 0 5 G Gold Contacts
Bushing Mounted Top Push Plunger 0 6 Examples ♦
Bushing Mounted Parallel Roller Plunger 0 7 Option Description
Bushing Mounted Cross Roller Plunger 0 8 0 2 # 16 AWG SJTO Cable
Adjustable Top Push Plunger 0 9 0 6 Side Entrance 18-4 SJTO Cable
Booted Top Push Plunger 1 0 1 0 Gray 18-4 SJTO Cable
Booted Parallel Roller Plunger 1 2 1 1 # 18 AWG Individual Conductors
Booted Cross Roller Plunger 1 3 2 1 Low Force (top plunger only) 18 oz.
♦List options in numerically ascending
order. Example: 9007MS01S030621.
See other options below.
Conductor
Length
Designator
c
MS Options
(Does not apply to ML except where noted)
Designator
c
No cable 00 #16 AWG SJTO cable 02
3 ft (0.9 m )—standard 01 Side entrance, #18 AWG SJTO cable, or Connector 12, 54, 55, 82, 84 t06
6 ft (1.8 m) 02 Gray #18 AWG SJTO cable 10
9 ft (2.7 m) 03 #18 AWG individual conductors 11
12 ft (3.7 m) 04 Male 4-pin mini-connector with 3 ft (0.9 m) cable (MS only) 12
18 ft (5.5 m) 05 Low force (NEMA Type 1 only)18 oz. 21
33 ft (10 m) 13 High Pre-Travel—adds 0.030 30
Male 4-pin micro-connector in housing (DC type) j (no cable) (MS only) 54
Male 5-pin micro-connector in housing (DC type) j (no cable) (ML only) 55
Tapped holes in top of plunger style housing (MS and ML) 81
Male 4-pin micro-connector in housing (AC type) (no cable) (MS only) 82
Black 18/5 SJTO Cable (ML only) 83
Male 4-pin micro-connector in housing (AC type) (no cable) (MS only) 84
9007MS02 Shown with
M12 Connector
Male Plug (face) Pin-outs
Option 54 (MS only) Option 55 (ML only) Option 12 (MS only) Option 82 (MS only) Option 84 (MS only)
N.O.
N.C.
C
GND
KEY
#4 #3
#1 #2 N.C.
N.C.
GND
KEY
N.O.
N.O.
#4
#3
#5
#1 #2
N.C.
#3
#4
GND
N.O.
#2
#1
C
N.O.
#2
N.C.
#3
G
#4
C
#1
Keys
Key N.C.
# 2
G
# 3
N.O.
# 4
C
# 1
159
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Miniature
Class 9007 Type MS and ML
Dimensions
Top Push Plunger Rotary Lever Booted Top Push Plunger
with Mid-Side Entry Cable
MS01, MLO1 MSO4, ML04 MS10, ML10
Parallel Roller Plunger Cross Roller Plunger Adjustable Top Push Plunger Omini-directional
MS02, ML02 MS03, ML03 MS09, ML09 MS05, ML05
Bushing Mounted Top Push Plunger Bushing Mounted
Parallel Roller Plunger Parallel Booted Roller Plunger Cross-Booted Roller Plunger
MS06, ML06 MS07, ML07 MS12, ML12 MS13, ML13
0.56
(14.2)
Dia.
Dia.
0.38
(9.6)
0.70
(17.78)
0.31
(7.87)
0.62
(15.8)
1.75
(44.45)
0.98
(25.0)TYP
0.20/(5.1) Dia. Typ.
mounting holes
0.40/(10.2) Dia.
C Bore
0.21/(5.3) deep
1.56
(39.6) TYP
Cable
SJTO
TYP
TYP
TYP
0.29
(7.3)
R
0.31
(7.8)
0.75
(19.0)
2.49
(63.25)
1.44
(36.58)
0.20 Dia. Mtg. Holes
0.406 Dia. C Bore
0.20 Deep
(0.25 Dia. Mtg.
holes optional)
1.39
(35.3)
0.91
(23.1)
0.77
(19.5)
0.98
(24.89)
Dual Dimensions inches
mm
.50
(12.7)
1.19
(30.22)
0.56
(14.2)
Dia.
Dia.0.13
(3.3)
1.19
(30.2)
#10-32
Hex Screw
and Locknu
t
min.
1.30
(33.0)
max.
1.5
(38.1)
5.74
(145.8)
0.64
(16.25)
Dia.
1.94
(49.27)
1.36
(34.5)
0.13
(3.3) 0.56
(14.2)
M14 x 1
Threaded
0.44
(11.17)
M14 x 1
Threaded
1.72
(43.7)
1.49
(37.8) 1.49
(37.8)
160
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
Miniature Enclosed Reed
Class 9007 Type XA
Description and Specifications
Sealed construction keeps contaminants out of the contact area, making it the ideal choice for low
voltage, low current circuits used by programmable controllers.
Type XA is designed for use in applications where contact reliability, environmental immunity, small size,
or low cost are required.
NOTE:
•Because reed switches are operated by a magnet, they should not be installed in areas where strong
magnetic fields may be present. The devices should always be checked for proper operation after
installation.
•Type XA cannot be used in Division 2 locations since the National Electrical Code (NEC) requires
provisions for conduit connection. The Type C reed switches have this provision for conduit but the
Type XA do not.
tOther cable lengths are available. Order by changing the last two numerical digits of the Type number to the length desired.
Example: An XA7303E with 15 ft (4.5 m) of cable would become an XA7315E.
NOTE: The XA switch is available with a 3 ft (0.9 m) cable and 3-pin Brad Harrison male connector No. 40904 (or equivalent). Form Y190.
Maximum Current Ratings for Control Circuit Contacts—Type XA
Cable Lengtht
ft (m)
Straight Plunger Roller Plunger Cross Roller Plunger
N.O. N.C. N.O. N.C. N.O. N.C.
Type Type Type Type Type Type
3 (0.9) XA7303E XA7503E XA7303D XA7503D XA7303DC XA7503DC
6 (1.8) XA7306E XA7506E XA7306D XA7506D XA7306DC XA7506DC
9 (2.7) XA7309E XA7509E XA7309D XA7509D XA7309DC XA7509DC
Operating Data
Dimensions
in. (mm)
Top Push Rod
(Type E)
Roller Plunger
(Types D, DC)
Initial position (D) 0.690 (17.5) 1.190 (30.2)
Trip position (B) 0.620 (15.7) 1.120 (28.4)
Pre-travel (E) 0.07 (1.8) 0.07 (17.8)
Reset position (C) maximum 0.655 (16.6) 1.155 (29.3)
Differential (F) 0.015 (0.38) 0.015 (0.38)
Final position (A) 0.492 (12.5) 0.992 (25.2)
Total stroke 0.198 (5.0) 0.198 (5.0)
Operating force (max.) 2.75 lb (0.31 N) 2.75 lb (0.31 N)
Contacts
The contact is a fully encapsulated, hermetically sealed reed, suitable for controlling solid-state loads as
well as industrial relays. Switches can also be used as inputs to intrinsically safe systems. Use of a
transient suppressor extends the life of the switch when used on heavy electrical loads.
Enclosure Construction Diecast zinc—baked, gray enamel finish. Meets NEMA Types 2, 4, 4X, 6P, 12 and 13 requirements.
Oil-tight, dust-tight, water-tight, and submersible.
Cable SJTOWA jacketed cable with 18 gauge wire.
Ambient Temperature -20 to +140 °F (-28.9 to +60 °C).
Agency Listings UL: File E42259 CCN NKCR CSA: File LR 25490, Class 3211 03
ABCD
E (PRETRAVEL)
INITIAL POSITION
CONTACTS RESET
CONTACTS TRIP
FINAL POSITION
F (DIFFERENTIAL)
Cross Roller Plunger
Straight Plunger
Roller Plunger
AC—50/60 Hz DC
Volts
Inductive (35% Power Factor) Resistive (75% Power Factor)
Volts
Resistive
Make Break Continuous
Carrying
Amperes
Make, Break, and
Continuous Carrying Amperes
Make and Break
Amperes Continuous
Carrying
Amperes
AVA AVA Single Throw
120 2.0 240 0.2 24 0.5 0.2 120 0.2 0.5
240 1.0 240 0.1 24 0.5 0.1 ———
Contact Diagrams Dimensions
Bk-W
Bk-W
0.070
0.198
0.035
0
Bk-W
Bk-W
0.070
0.198
0.035
0
9007XA73 (N.O.)
9007XA75 (N.C.)
Dual Dimensions inches
mm
161
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007AW Heavy Duty Industrial
Precision, Oiltight
Lever Arm And Plunger Types
Select Switch
Select Operator
Lever Arm Type Without
Lever Arm.
Select from CCW
Operation c
Roller Plunger Type
With Micrometer
Adjustment
Push Rod Plunger
Type
With Micrometer
Adjustment
Mounting Contacts Type Type Type
Surface
Mounting
Plug-in
1 N.O.—1 N.C. AW16 AW36 AW46
2 N.O. u——
2 N.C. AW19u——
Surface Mounting
Nonplug-in Standard Box 1 N.O.—1 N.C. AW12 AW32 AW42
Surface
Mounting
Nonplug-in
Deep Box
1 N.O.—1 N.C. AW14 — —
2 N.O.—2 N.C. AW18 AW38 —
Open Type
(Without Box)
Plug-in
1 N.O.—1 N.C. AO16 AO36 —
2 N.O. u——
2 N.C. u——
Open Type
(Without Box)
Nonplug-in
1 N.O.—1 N.C. AO12 — —
2 N.O.—2 N.C. AO18 — —
Flush Mounting 1 N.O.—1 N.C. AF12 — —
Nominal
Operating
Data
in. (mm)
Pre-travel 5° 0.09 (2.3) 0.09 (2.3)
Total-travel 30° 0.25 (6.3) ±0.06 (1.5) Adjustable 0.25 (6.3) ±0.06 (1.5) Adjustable
Differential 2.5° 0.05 (1.3) 0.05 (1.3)
Reverse Over-travel 25° — —
Operating Torque or Force 2.75 lb-in (0.31 N•m) 3 lb-in (0.34 N•m) 3 lb-in (0.34 N•m)
Repeat Accuracy
±0.002 (0.05)
Linear travel of cam
on 1.38 (35) lever arm
±0.001 (0.02) ±0.001 (0.02)
cField convertible to CW operation.
u2 N.O. contact only when Type AW19 is operated in clockwise direction. 2 N.C. contacts only when Type AW19 is operated in
counterclockwise direction.
Lever arms, see page 190.
Plunger Type
Dual Dimensions inches
mm
Lever Arm Type
Approximate Dimensions
Type AW Type AO Type AW42, 46, 48, and 49
Type AW32, 36, and 38
Type C D E F G H
AW12 0.31 (7.9) 2.69 (68.3) 2.19 (56) 1.16 (29.4) 2.5–2.56 (63.5–65) 2.06–2.13 (52.3–54)
AW14
AW16
AW18
AW19
1.25 (32) 3 (76) 2.5 (63.5) 1.47 (37) 2.81–2.88 (71–73) 2.38–2.44 (60–62)
AO12 — — — 1.03 (26 1.06–1.13 (27–29) 0.63–0.69 (16–17.5)
AO18 — — — 1.13 (29) 1.06–1.13 (27–29) 0.63–0.69 (16–17.5)
Type A B C D
AW32 and AW42 0.31
(7.9)
2.22
(56)
1.16
(29.4)
1.81
(46)
AW36, 38, 46, 48, and
49
1.25
(32)
2.53
(64)
1.47
(37.3)
2.13
(5.4)
0
.
25
6
.35 Adjustment
G
0.19
4.8
0.25
6.35
0.06
1.5
0.44
11.2
0.5
12.7
Pipe Tap0.25
6.35
0.19
4.8
E
D
C
0.69
17.5
F
H
3.06
77.7
0.63
16.0
0.19
4.8
ON AW14 and AW18, 0.5 Pipe
Tap may be placed here for
straight through wiring.
1.44
36.6
1.06
27.0
0.53
13.5
3.5
88.9
3.88
98.5
(6) 0.198 Dia.
Mtg. Holes
0.84
21.3
Adjustment
G
H
0.25
6.35
0.25
6.35
◗
◗
0.19
4.8
0.19
4.8
❅
❅
0.06
1.5 0.06
1.5
F
0.75
19.0
1.25
31.75
1.38
35.0
0.69
17.5
3.09
78.5
3.47
88.1
0.31
7.9
2.5
63.5
0.32
8.1
0.83
21.1
2 - 196 Dia. Mtg. Holes
Dia.
0.44
11.7
D
0.31
7.9
C
A
B
Initial
Position
0.44
11.2
0.38
9.6
Dia. roller can be turned 90
o
0.63
16.0
Initial
Position
0.69
17.5
0.22
5.6
0.38
9.6
0.19
4.8
D
0.13
3.3
C
A
B
0.19
4.8
0.75
19.0
(6) 0.198 Dia. mtg. holes
3.06
77.7 3.5
88.9
3.88
98.5
1.44
36.6
1.06
27.0 0.53
13.5
0.5
12.7 Pipe Tap
162
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Standard and Compact
Standard plug-in body type With head for linear movement
with 1 cable entry (1) side plunger top plunger
The standard plug-in body types
with one cable entry are also
available with reed contacts
Page 164 Page 165
With reed contacts Page 168 Page 173
With head for rotary movement (lever) With head for multi-directional movement
Page 166 Page 167
With reed contacts Page 170 Page 171
Compact plug-in body type With head for linear movement
with one cable entry (1) Side plunger Top plunger
Page 172 Page 173
With head for rotary movement (lever) With head for multi-directional movement
Page 174 Page 175
1. Factory modifications: see pages 176 to 180
163
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Standard and Compact
Environmental characteristics
Conforming to standards Products NEMA 250, EN 60947-1, EN 60947-5-1, IEC 60947, UL 508, C22-2-14-95, e conformity documentation
Product certifications UL, CSA, e
Protective treatment Epoxy powder coat (additional protection available)
Ambient air temperature Operation -20…+185 °F (-28.9…+85 °C), wider range available
Storage -20…+185 °F (-28.9…+85 °C), wider range available
Vibration resistance Conforming to IEC 60068-2-6 25 gn (10…150 Hz, 11 ms) (Reed switch good for 18.5g only)
Shock resistance Conforming to IEC 60068-2-27 60 gn (9 ms)
40 gn (9 ms) for reed switch
Electric shock protection Conforming to IEC 61140 Class 0
Degree of protection Conforming to IEC 60529 IP 67
Cable entry or connector (1) Depending on model 1/2-14 NPT, M20 x 1.5, ISO cable entry, 5-pin mini connector, 4-pin micro connector
Materials Bodies, heads, levers Bodies and heads in Zamak® zinc alloy, levers and rods in zink, steel, stainless steel, Delrin® resin.
1. A wide range lof connectors are available. Contact your local field office.
Contact block characteristics
Rated operational
characteristics hard contacts
-AC Voltage
(top half of body)
9007CO52 (compact single) NEMA A600 (Ue = 600 V, Ie = 1.2 A); Ithe = 10 A
9007CO54 (single pole) NEMA A600 (Ue = 600 V, Ie = 1.2 A); Ithe = 10 A
9007CO62 (two pole) NEMA A600 (Ue = 600 V, Ie = 1.2 A); Ithe = 10 A
9007CO66 (two pole two stage) NEMA A600 (Ue = 600 V, Ie = 1.2 A); Ithe = 10 A
9007CO68 (two pole neutral) NEMA A600 (Ue = 600 V, Ie = 1.2 A); Ithe = 10 A
Reed switches,
complete body
9007C84 (1 N.O.) NEMA C600 (Ue = 600 V, Ie = 0.3 A); Ithe = 2.5 A
9007C86 (1 N.C.) NEMA C600 (Ue = 600 V, Ie = 0.3 A); Ithe = 2.5 A
Rated operational
characteristics hard contacts
-DC Voltage
(top half of body)
9007CO52 (compact single) NEMA Q600 (Ue = 600 V, Ie = 0.1 A); Ithe = 2.5 A
9007CO54 (single pole) NEMA Q600 (Ue = 600 V, Ie = 0.1 A); Ithe = 2.5 A
9007CO62 (two pole) NEMA R300 (Ue = 250 V, Ie = 0.11 A); Ithe = 1.0 A
9007CO66 (two pole two stage) NEMA R300 (Ue = 250 V, Ie = 0.11 A); Ithe = 1.0 A
9007CO68 (two pole neutral) NEMA R300 (Ue = 250 V, Ie = 0.11 A); Ithe = 1.0 A
Reed switches,
complete body
9007C84 (1 N.O.) NEMA Q150 (Ue = 125 V, Ie = 0.55 A); Ithe = 2.5 A
9007C86 (1 N.C.) NEMA Q150 (Ue = 125 V, Ie = 0.55 A); Ithe = 2.5 A
Rated insulation voltage 600 V
Rated impulse withstand voltage 2,500 Vac for 1 minute for CE; 2,200 Vac for 1 minute for UL; and 2,640 Vac for 1 s for CSA
Positive opening Special Y1561 Special Y1561 (one pole slow break only)
Short circuit protection 10 A. Bussman Class CC KTK-R-10 fuse non-time-delay
Terminal wire sizes (cabling/screw clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Maximum actuation speed 15.2 mpm / 27.4 mpm (50 fpm / 90 fpm) with 45 degree cam angle, levers only
Electrical durability 1 million operating cycles
Types of contact elements IEC 60947-5-1 NEMA JIS
Form Symbol Description Form Symbol Description Form Symbol Description
Example: 9007C54 single-pole limit switch,
Form Z, same polarity A
X
Single break A—3—
Double break
B
Y
Single break B—2—
Double break
C—C—1Single break
Za Same polarity Z“Same
polarity”
only
Double break
Zb Electrically
separate
164
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Standard Body
Type of head Side Plunger (mounting by the body)
Standard plug-in body type
Type of operator
Side roller plunger,
spring return,
vertical roller (1)
Side push rod plunger,
spring return
Side push rod plunger,
adjustable (2)
spring return
Side push rod plunger,
maintained contact
Catalog numbers
1 N.O. 1 N.C. snap action 9007C54F 9007C54G 9007C54GD 9007C54H
2 N.O. 2 N.C. snap action 9007C62F
9007C62G 9007C62GD 9007C62H
2 N.O. 2 N.C. Two stage snap action 9007C66F 9007C66G 9007C66GD
Weight, kg (lb) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation On end
Type of actuation
Pre-travel 2 mm (0.08 in.) 3.6 mm (0.14 in.)
Pre-travel two Stage First stage 2 mm (0.08 in.)
First stage to second stage 0.5 mm (0.02 in.)
Total travel 6.3 mm (0.25 in.)
Differential 0.8 mm (0.03 in.)
Reverse overtravel —
Minimum force or
torque 1 pole & 2 pole 4 lb (17.8 N) 7 lb (31.1 N)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22AWG (2.05–0.644 mm2) wires maximum
Repeatability (linear travel of cam) 0.03 mm (0.001 in.) —
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. Can be converted to horizontal roller type in the field. To order horizontal roller version add the letter H at the end of the equivalent vertical roller version type.
2. To lock the nut in the desired position, crimp the slot near the bottom of the nut.
34
12 1-2
3-4
1-2
3-4
0.8
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.8
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.8
2
6.3 mm 0
1-2
3-4
1-2
3-4
3.6
6.3 mm 0
3
4
2
1
7
8
6
50.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0 0.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0 0.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
3.6
6.3 mm 0
3
4
2
1
7
8
6
5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
Dimensions:
pages 182 to 185
165
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Standard Body
Type of head Top Plunger (mounting by the body)
Standard plug-in body type
Type of operator Top roller plunger
spring return
Top push rod plunger
spring return
Top push rod plunger
adjustable (1)
spring return
Palm operated
(2)
Catalog numbers
1 N.O. 1 N.C. snap action 9007C54D 9007C54E 9007C54ED 9007C54R (2)
2 N.O. 2 N.C. snap action 9007C62D 9007C62E 9007C62ED 9007C62R (2)
2 N.O. 2 N.C. Two stage snap action 9007C66D 9007C66E 9007C66ED 9007C66R (2)
Weight, kg (lb) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation On end
Type of actuation
Pre-travel 2 mm (0.08 in.)
Pre-travel two Stage First stage 2 mm (0.08 in.)
First stage to second
stage 0.3 mm (0.01 in.)
Total travel 6.3 mm (0.25 in.)
Differential 0.5 mm (0.02 in.)
Reverse overtravel —
Minimum force or
torque 1 pole & 2 pole 3 lb (13.3 N) 7 lb (31.1 N)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability (linear travel of cam) 0.03 mm (0.001 in.)
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. To lock the nut in the desired position, crimp the slot near the bottom of the nut.
2. Does not include mushroom button. Must be ordered separately see page 189.
34
12
1-2
3-4
1-2
3-4
0.5
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.5
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.5
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.5
2
6.3 mm 0
3
4
2
1
7
8
6
50.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0 0.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0 0.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0 0.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0
3
4
2
1
7
8
6
5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
Dimensions:
pages 182 to 185
166
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Standard Body
Dimensions:
pages 182 to 185
Type of head Rotary (lever arm type) (1)
Standard plug-in body
type
Type of operator Standard pre-travel,
spring return
Low differential,
spring return
Neutral position Light operating torque
spring return Maintained contact
Standard pre-travel,
spring return
Low differential,
spring return
Type of direction CW & CCW (2) CW & CCW (2) CW & CCW CW & CCW CW & CCW (2) CW (trip) CCW (reset)
Catalog numbers
1 N.O., 1 N.C. snap action 9007C54B2 9007C54A2 9007C54N2 9007C54C
2 N.O., 2 N.C. snap action 9007C62B2 9007C62A2 9007C62N2 9007C62C
2 N.O., 2 N.C. snap action
Neutral position 9007C68T10 9007C68T5
2 N.O., 2 N.C.
Two stage snap action 9007C66B2 9007C66A2 9007C66N2
Weight, kg (lb) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25)
Contact operation contact closed contact open
Characteristics (nominal operating data)
Switch actuation By 30° cam
Type of actuation
Pre-travel 10° 5° 10° 5° 10° 45°
Pre-travel two stage
First stage 10° 5° — — 10° —
First stage to second stage 2.5° 1.5° — — 2.5° —
Total travel 90° 90°
Differential 4° 2° 4° 2° 4° —
Reverse overtravel 90° —
Operating torque/force
1 pole & 2 pole 4 lb-in (0.45 N•m) 25 oz-in (0•18 N•m) 3 lb-in (0.34 N•m)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability
(linear travel of cam) 0.05 mm (± 0.002 in.) 0.03 mm (± 0.001 in.) 0.05 mm (± 0.002 in.) 0.05 mm (± 0.002 in.) 0.05 mm (± 0.002 in.) 0.05 mm (± 0.002 in.)
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. Lever arm type must be ordered separately from pages 190 to 195.
2. These devices are factory set to operate the contacts in both the CW and CCW directions. Mode of operation is field convertible to CW only or CCW only. To order factory converted
devices: For CCW only operation, change the 2 at the end of the Type number to 1 (for example, C54B2 becomes C54B1). For CW only operation, delete the 2 at the end of the Type
number (for example C54B2 becomes C54B).
Mode of operation of the lever arm is easily convertible to clockwise or both. Simply pull out and rotate the arrow to the letters representing the desired
direction—CW, CCW, or CW/CCW.
34
12
1-2
3-4
1-2
3-4
4°
10°
90°0
1-2
3-4
1-2
3-4
2°
5°
90°0
1-2
3-4
1-2
3-4
4°
10°
90°0
1-2
3-4
1-2
3-4
45°
90°0
3
4
2
1
7
8
6
5
10°
4°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90° 0 2°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
5°
90° 0
10°
4°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90° 0
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
45°
90° 0
3
4
2
1
7
8
6
5
10° 0 10°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
4°4°
90°CW
90°CCW
CCW
CW
0
5° 0 5°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2°2°
90°CW
90°CCW
CCW CW
0
3
4
2
1
7
8
6
54°
4°
10° 12.5°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90°
0
5° 6.5°
2°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2° 90°
0
4°
4°
10° 12.5°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90°
0
C
W
/
C
C
W
C
W
W
/
CW
C
C
C
C
W
167
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Standard Body
Type of head Flexible operator (wobble stick)
Standard plug-in body type
Type of operator Universal (1) Wobble stick
Delrin® extension (1)
Wobble stick
wire extension (1)
Wobble stick
coil spring extension (1) Cat whisker
Catalog numbers
1 N.O. 1 N.C. snap action 9007C54JKC 9007C54J 9007C54K 9007C54KC 9007C54L
2 N.O. 2 N.C. snap action 9007C62JKC 9007C62J 9007C62K 9007C62KC 9007C62L
2 N.O. 2 N.C. Two stage snap action 9007C66JKC 9007C66J 9007C66K 9007C66KC 9007C66L
Weight, kg (lb) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation Object from any direction
Type of actuation
Pre-travel 10° (any direction) 20°
Pre-travel two stage
First stage 10° (any direction) 20°
First stage to second stage 4° 5°
Total travel 90°
Differential 36°
Reverse overtravel —
Operating torque/force
1 pole & 2 pole 3 lb-in (0.34 N•m) 7 oz-in (0.05 N•m)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability
(linear travel of cam) —
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. Wobble stick extensions are available separately for the universal head. See page 189.
34
12
1-2
3-4
1-2
3-4
3°
10°
90°
0
1-2
3-4
1-2
3-4
3°
10°
90°
0
1-2
3-4
1-2
3-4
3°
10°
90°
0
1-2
3-4
1-2
3-4
3°
10°
90°
0
1-2
3-4
1-2
3-4
6°
20°
90°0
3
4
2
1
7
8
6
5
10°
3°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90° 0
10°
3°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90° 0
10°
3°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90° 0
10°
3°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90° 0 6°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
20°
90° 0
3
4
2
1
7
8
6
5
10°
3°
3°
14°
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0
90°
10°
3°
3°
14°
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0
90°
10°
3°
3°
14°
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0
90°
10°
3°
3°
14°
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0
90° 6°
0 90°
6°
25°20°
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
Dimensions:
pages 182 to 185
168
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Standard Body—Reed Contacts
Type of head Side Plunger (mounting by the body)
Standard plug-in body type
Type of operator
Side roller plunger
spring return
vertical roller (1)
Side push rod plunger
spring return
Side push rod plunger
adjustable (2)
spring return
Side push rod plunger
maintained contact
Catalog numbers
1 N.O. Reed contacts snap action 9007C84F 9007C84G 9007C84GD 9007C84H
1 N.C. Reed contacts snap action 9007C86F 9007C86G 9007C86GD 9007C86H
Weight, kg (lb) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation On end
Type of actuation
Pre-travel 2.8 mm (0.110 in.) 3.6 mm (0.14 in.)
Total travel 6.3 mm (0.25 in.)
Differential 1.8 mm (0.07 in.) —
Reverse overtravel — —
Minimum force or torque
1 pole & 2 pole 4 lb (17.8 N) 7 lb (31.1 N)
Terminal wire sizes
(Cabling/Screw Clamp)
1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability
(linear travel of cam) 0.076 mm (± 0.003 in.) —
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. Can be converted to horizontal roller type in the field. To order horizontal roller version add the letter H at the end of the equivalent vertical roller version type.
2. To lock the nut in the desired position, crimp the slot near the bottom of the nut.
34
3-4
3-4
1.8
2.8
6.3 mm 0
3-4
3-4
1.8
2.8
6.3 mm 0
3-4
3-4
1.8
2.8
6.3 mm 0
3-4
3-4
3.6
6.3 mm 0
12
1-2
1-2
1.8
2.8
6.3 mm 0
1-2
1-2
1.8
2.8
6.3 mm 0
1-2
1-2
1.8
2.8
6.3 mm 0 1-2
1-2
6.3 mm 0
3.6
Dimensions:
pages 182 to 185
169
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Standard Body—Reed Contacts
Type of head Top Plunger (mounting by the body)
Standard plug-in body type
Type of operator Top roller plunger
spring return
Top push rod plunger
spring return
Top push rod plunger
adjustable (1)
spring return
Palm operated
(2)
Catalog numbers
1 N.O. Reed contacts snap action 9007C84D 9007C84E 9007C84ED 9007C84R (2)
1 N.C. Reed contacts snap action 9007C86D 9007C86E 9007C86ED 9007C86R (2)
Weight, kg (lb) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation On end
Type of actuation
Pre-travel 2.5 mm (0.100 in.)
Total travel 6.3 mm (0.25 in.)
Differential 1.3 mm (0.05 in.)
Reverse overtravel —
Minimum force or torque
1 pole & 2 pole 4 lb (17.8 N)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability
(linear travel of cam) 0.076 mm (± 0.003 in.)
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. To lock the nut in the desired position, crimp the slot near the bottom of the nut.
2. Does not include mushroom button. Must be ordered separately from page 189.
34
3-4
3-4
1.3
2.5
6.3 mm 0
3-4
3-4
1.3
2.5
6.3 mm 0
3-4
3-4
1.3
2.5
6.3 mm 0
3-4
3-4
1.3
2.5
6.3 mm 0
12
1-2
1-2
1.3
2.5
6.3 mm 0
1-2
1-2
1.3
2.5
6.3 mm 0
1-2
1-2
1.3
2.5
6.3 mm 0
1-2
1-2
1.3
2.5
6.3 mm 0
Dimensions:
pages 182 to 185
170
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Standard Body—Reed Contacts
Type of head Rotary (lever arm type) (1)
Standard plug-in body type
Type of operator Standard pre-travel
spring return
Low differential
spring return
Light operating torque
spring return Maintained contact
Type of direction CW & CCW (2) CW & CCW (2) CW & CCW (2) CW (trip) CCW (reset)
Catalog numbers
1 N.O. Reed contacts snap action 9007C84B2 9007C84A2 9007C84N2 9007C84C
1 N.C. Reed contacts snap action 9007C86B2 9007C86A2 9007C86N2 9007C86C
Weight, kg (lb) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation By 30° cam
Type of actuation
Pre-travel 13° 7° 13° 45°
Total travel 90°
Differential 7° 4° 7° —
Reverse overtravel 90° 90° 90° —
Operating torque force
1 pole & 2 pole 4 lb-in (17.8 N•m) 25 oz-in (0.18 N•m) 3 lb-in (0.34 N•m)
Terminal wire sizes
(Cabling/Screw Clamp)
1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability
(linear travel of cam) 0.15 mm (± 0.006 in.) 0.076 mm (± 0.003 in.) 0.15 mm (± 0.006 in.) 0.15 mm (± 0.006 in.)
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. Lever arm type must be ordered separately from pages 190 to 195.
2. These devices are factory set to operate the contacts in both the CW and CCW directions. Mode of operation is field convertible to CW only or CCW only. To order factory
converted devices: For CCW only operation, change the 2 at the end of the Type number to 1 (for example, C54B2 becomes C54B1). For CW only operation, delete the 2 at the end
of the Type number (for example, C54B2 becomes C54B).
Mode of operation of the lever arm is easily convertible to clockwise or both.
Simply pull out and rotate the arrow to the letters representing the desired direction—CW, CCW, or CW/CCW.
34
3-4
3-4
7°
13°
90° 0
3-4
3-4
4°
7°
90° 0
3-4
3-4
7°
13°
90° 0 3-4
3-4
45°
90° 0
12
1-2
1-2
7°
13°
90° 0
1-2
1-2
4°
7°
90° 0
1-2
1-2
7°
13°
90° 0 1-2
1-2
45°
90° 0
C
W
/
C
C
W
C
W
W
/
CW
C
C
C
C
W
Dimensions:
pages 182 to 185
171
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Standard Body—Reed Contacts
Type of head Flexible operator (wobble stick)
Standard plug-in body type
Type of operator Universal (1) Wobble stick
Delrin® extension (1)
Wobble stick
wire extension (1)
Wobble stick
coil spring extension (1) Cat whisker
Catalog numbers
1 N.O. Reed contacts snap action 9007C84JKC 9007C84J 9007C84K 9007C84KC 9007C84L
1 N.C. Reed contacts snap action 9007C86JKC 9007C86J 9007C86K 9007C86KC 9007C86L
Weight, kg (lb) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25) 0.568 (1.25)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation By any moving object in any direction
Type of actuation
Pre-travel 13° (any direction) 25°
Total travel 90°
Differential 11° 18°
Reverse overtravel —
Operating torque/force
1 pole & 2 pole 3 lb-in (0.34 N•m) 7 oz-in (0.05 N•m)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability
(linear travel of cam) —
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. Wobble stick extensions are available separately for the universal head. See page 189.
Acceptable wire sizes: 12-22 AWG Recommended,
Terminal clamp torque: 7 lb-in (0.80 N•m).
34
11°
3-4
3-4
13°
90° 0 11°
3-4
3-4
13°
90° 0 11°
3-4
3-4
13°
90° 0 11°
3-4
3-4
13°
90° 0 18°
3-4
3-4
25°
90° 0
12
11°
1-2
1-2
13°
90° 0 11°
1-2
1-2
13°
90° 0 11°
1-2
1-2
13°
90° 0 11°
1-2
1-2
13°
90° 0 18°
1-2
1-2
25°
90° 0
Dimensions:
pages 182 to 185
172
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Compact Body
Type of head Side Plunger (mounting by the body)
Compact plug-in body type
Type of operator
Side roller plunger
spring return vertical roller
(1)
Side push rod plunger
spring return
Side push rod plunger
adjustable (2)
spring return
Side push rod plunger
maintained contact
Catalog numbers
1 N.O. 1 N.C. snap action 9007C52F 9007C52G 9007C52GD 9007C52H
Weight, kg (lb) 0.456 (1.01) 0.445 (0.98) 0.422 (0.93) 0.568 (1.25)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation On end
Type of actuation
Pre-travel 2 mm (0.08 in.) 3.6 mm (0.14 in.)
Pre-travel two Stage First stage 2 mm (0.08 in.) —
First stage to second stage 0.5 mm (0.02 in.) —
Total travel 6.3 mm (0.25 in.) 6.3 mm (0.25 in.)
Differential 0.8 mm (0.03 in.) —
Reverse overtravel — —
Minimum force or torque 1 pole & 2 pole 4 lb (17.8 N) 7 lb (31.1 N)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability
(linear travel of cam) 0.03 mm (0.001 in.) —
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry. Prewired options available.
1. Can be converted to horizontal roller type in the field. To order horizontal roller version add the letter H at the end of the equivalent vertical roller version type.
2. To lock the nut in the desired position, crimp the slot near the bottom of the nut.
34
12
1-2
3-4
1-2
3-4
0.8
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.8
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.8
2
6.3 mm 0
1-2
3-4
1-2
3-4
3.6
6.3 mm 0
Dimensions:
pages 182 to 185
173
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Compact Body
Type of head Top Plunger (mounting by the body)
Compact plug-in body type
Type of operator Top roller plunger
spring return
Top push rod plunger
spring return
Top push rod plunger
adjustable (1)
spring return
Palm operated
(2)
Catalog numbers
1 N.O. 1 N.C. snap action 9007C52D 9007C52E 9007C52ED 9007C52R (2)
Weight, kg (lb) 0.169 (0.43) 0.169 (0.43) 0.422 (0.93) 0.568 (1.25)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation On end
Type of actuation
Pre-travel 2 mm (0.08 in.)
Pre-travel two Stage First stage 2 mm (0.08 in.)
First stage to second stage 0.03 mm (0.01 in.)
Total travel 6.3 mm (0.25 in.)
Differential 0.5 mm (0.02 in.)
Reverse overtravel
Minimum force or torque 1 pole & 2 pole 3 lb (13.3 N)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability
(linear travel of cam) 0.03 mm (0.001 in.)
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry. Prewired options available.
1. To lock the nut in the desired position, crimp the slot near the bottom of the nut.
2. Does not include mushroom button. Must be ordered separately see page 189.
34
12
1-2
3-4
1-2
3-4
0.5
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.5
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.5
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.5
2
6.3 mm 0
Dimensions:
pages 182 to 185
174
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Compact Body
Type of head Rotary (lever arm type) (1)
Compact plug-in body type
Type of operator Standard pre-travel
spring return
Low differential
spring return
Light operating torque
spring return Maintained contact
Type of direction CW & CCW (2) CW & CCW (2) CW & CCW (2) CW (trip) CCW (reset)
Catalog numbers
1 N.O. 1 N.C. snap action 9007C52B2 9007C52A2 9007C52N2 9007C52C
Weight, kg (lb) 0.481 (1.06) 0.481 (1.06) 0.481 (1.06) 0.481 (1.06)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation By 30° cam
Type of actuation
Pre-travel 10° 5° 10° 45°
Pre-travel two Stage
First stage 10° 5° 10° —
First stage to second stage 2.5° 1.5° 2.5° —
Total travel 90° 90° 90° 90°
Differential 4° 2° 4° —
Reverse overtravel 90° 90° 90° —
Operating torque/force
1 pole & 2 pole 4 lb-in (0.45 N•m) 25 oz-in (0.18 N•m) 3 lb-in (0.34 N•m)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability
(linear travel of cam) 0.05 mm (± 0.002 in.) 0.03 mm (± 0.001 in.) 0.05 mm (± 0.002 in.) 0.05 mm (± 0.002 in.)
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. Lever arm type must be ordered separately from pages 190 to 195.
2. These devices are factory set to operate the contacts in both the CW and CCW directions. Mode of operation is field convertible to CW only or CCW only.
To order factory converted devices: For CCW only operation, change the 2 at the end of the Type number to 1 (for example, C52B2 becomes C52B1). For CW only operation, delete
the 2 at the end of the Type number (for example, C52B2 becomes C52B).
Mode of operation of the lever arm is easily convertible to clockwise or both.
Simply pull out and rotate the arrow to the letters representing the desired direction—CW, CCW, or CW/CCW.
34
12
1-2
3-4
1-2
3-4
4°
10°
90°0
1-2
3-4
1-2
3-4
2°
5°
90°0
1-2
3-4
1-2
3-4
4°
10°
90°0
1-2
3-4
1-2
3-4
45°
90°0
C
W
/
C
C
W
C
W
W
/
CW
C
C
C
C
W
Dimensions:
pages 182 to 185
175
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Compact Body
Type of head Flexible operator (wobble stick)
Compact plug-in body type
Type of operator Universal (1) Wobble stick
Delrin® extension (1)
Wobble stick
wire extension (1)
Wobble stick
coil spring extension (1) Cat whisker
Catalog numbers
1 N.O. 1 N.C. 9007C52JKC 9007C52J 9007C52K 9007C52KC 9007C52L
Weight, kg (lb) 0.468 (1.03) 0.568 (1.25) 0.540 (1.19) 0.568 (1.25) 0.468 (1.03)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation By any moving
Type of actuation
Pre-travel 10° (any direction) 20°
Pre-travel two stage
First stage 10° (any direction) 20°
First stage to second stage 4° 5°
Total travel 90°
Differential 3° 6°
Reverse overtravel —
Operating torque/force
1 pole & 2 pole 3 lb-in (0.34 N•m) 7 oz-in (0.05 N•m)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability
(linear travel of cam) —
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. Wobble stick extensions are available separately for the universal head. See page 189.
34
12
1-2
3-4
1-2
3-4
3°
10°
90°
0
1-2
3-4
1-2
3-4
3°
10°
90°
0
1-2
3-4
1-2
3-4
3°
10°
90°
0
1-2
3-4
1-2
3-4
3°
10°
90°
0
1-2
3-4
1-2
3-4
6°
20°
90°0
Dimensions:
pages 182 to 185
176
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Factory Modifications (Forms)
Special features and modifications
Special features do not apply to 9007CR unless noted. Not field installable, except where noted.
Shaft equipped with hub for mounting larger diameter lever used with 9007T/FT limit switches
Any rotary lever arm 9007C, CF or CR switch can be furnished with an optional shaft and hub combination which will
accept the lever arms normally used with 9007T and FT limit switches. To order, add S9 as suffix to the device
number. For example, to order a 9007C54B2 with this modification, order as a 9007C54B2S9. For details about
switches and lever arms that can be furnished with this modification, see the appropriate catalog or the Digest.
Description Suffix to add to the
device catalog number
Weight
kg (lb)
Optional hub for 9007T/FT levers S9 0.018 (0.04)
Hub only: can be field installed on rotary shaft; see accessories, page 181
Addition of LED pilot light (1)
Description Suffix to add to the
device catalog number
Weight
kg (lb)
LED Pilot light, 24 to 120 V AC or DC
on plug-in type switch
(9007C52, C54, C62, C66, C68 or (2))
Addition of LED pilot light in parallel with
N.O. contact (light normally on) P5 (2) 0.57 (1.25)
Addition of LED pilot light in parallel with
N.C. contact (light normally off) P6 (2) 0.57 (1.25)
Addition of two LED pilot lights, one in
parallel with N.O. contact (light normally on),
one in parallel with N.C. contact (light
normally off)
P7 0.57 (1.25)
Addition of two LED pilot lights in parallel
with N.O. contacts (lights normally on) P8 (3) 0.57 (1.25)
Addition of two LED pilot lights in parallel
with N.C. contacts (lights normally off) P9 (3) 0.57 (1.25)
Addition of one isolated LED pilot light (light
on when load is energized) P10 (4) 0.57 (1.25)
1. Bleeder circuit must be added to ensure PLC compatibility.
2. 9007C84 and C86 are available with P5 or P6 pilot lights only.
3. 9007C62, C66 or C68 only.
4. 9007C54 only. Not available with prewired receptacles.
Examples of complete units with pilot lights in standard plug-in body type
Single pole Catalog number Weight
kg (lb)
Side plunger 9007C54FP6 0.57 (1.25)
Top plunger 9007C54DP6 0.57 (1.25)
9007C54EP6 0.57 (1.25)
Rotary 9007C54B2P6 0.57 (1.25)
Wobble stick 9007C54LP6 0.57 (1.25)
9007C54JP6 0.57 (1.25)
Two poles
Side plunger 9007C62FP6 0.57 (1.25)
Top plunger 9007C62DP6 0.57 (1.25)
9007C62EP6 0.57 (1.25)
Rotary 9007C62B2P6 0.57 (1.25)
Wobble stick 9007C62LP6 0.57 (1.25)
9007C62JP6 0.57 (1.25)
S9
Rotary head shown
with S9 option
A
CR2
CR1
L2
L1
B
Form P5 Thru P9
Light normally on
Light normally off
CR2
L2
L1
CR1
Form P10
*
Customer
installed
jumper
* Only one of the jumpers may be
used.
Pilot light is ON when load is
energized
177
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Factory Modifications (Forms)
Special features and modifications (continued)
Special features do not apply to 9007CR unless noted. Not field installable, except where noted.
Manifold mounting
Description
Suffix to add to the
device catalog
number
Weight
kg (lb)
Manifold mounting available on standard and compact types.
Replaces existing type B installations if new hole is drilled to
match knockout. Supersedes type C with form Y205.
Receptacle is furnished with a wiring hole and a gasket in the
base.
Y2051 0.57 (1.25)
Special chemical resistant coating (includes Viton®
fluorocarbon seals—Y140, and stainless steel head and body
screws) (1)
L3 0.57 (1.25)
Low temperature – lever types only: limit switch will operate in
an ambient temperature range of -40 to 185 °F (standard limit
switch ambient temperature range is -20 to 185 °F). Minimum
temperature is based on the absence of freezing moisture or
water.
Y128 0.57 (1.25)
Viton fluorocarbon gaskets and seals (1)
Substitution of Viton fluorocarbon gaskets and seals on:
Lever arm type, standard box (Viton fluorocarbon shaft
seals on lever arm types as standard) Y140 0.57 (1.25)
Lever arm type, compact box (Viton fluorocarbon shaft
seals on lever arm types as standard) Y140 0.57 (1.25)
Plunger type, standard box Y140 0.57 (1.25)
Plunger type, compact box Y140 0.57 (1.25)
Substitution of Viton fluorocarbon boot only on plunger
type switches Y1401 0.57 (1.25)
1. Fluorocarbon (as found in Viton seals) has been shown to resist sunlight aging problems.
Mini and micro connectors, ISO M20 (Form M11)
To order 9007C with ISO M 20 thread add the suffix M11 to the device number.
Examples of complete unit catalog numbers with ISO M20 thread in standard plug-in body type
Type of head Catalog number Weight
kg (lb)
Single pole
Side plunger 9007C54FM11 0.57 (1.25)
Top plunger 9007C54DM11 0.57 (1.25)
9007C54EM11 0.57 (1.25)
Rotary 9007C54B2M11 0.57 (1.25)
Wobble stick 9007C54LM11 0.57 (1.25)
9007C54JM11 0.57 (1.25)
Two poles
Side plunger 9007C62FM11 0.57 (1.25)
Top plunger 9007C62DM11 0.57 (1.25)
9007C62EM11 0.57 (1.25)
Rotary 9007C62B2M11 0.57 (1.25)
Wobble stick 9007C62LM11 0.57 (1.25)
9007C62JM11 0.57 (1.25)
15
0.58
9
0.36
16
7
0.61
x
x
0.29
Y2051
Form
Y205
178
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Factory Modifications (Forms)
Special features and modifications (continued)
Special features do not apply to 9007CR unless noted. Not field installable, except where noted.
Pre-wired receptacle (1) (2)
Description For use Suffix to add to the device
catalog number
Weight
kg (lb)
Plug-in limit switch furnished with pre-wired mini 5-pin Brad Harrison male connector
Single pole For use with Brad Harrison female portable plug
No.41306, 41307 or 41308 (or equal). Y1901 0.60 (1.33)
Same as Y1901 but with different wire color
coding Y1905 0.60 (1.33)
Tamper proof screws in complete switch only
Single pole Same as Y1901 but with tamper proof screws
on head and body Y1903 0.60 (1.33)
Similar to Y1905 except for double pole device Y19013 0.60 (1.33)
1. Plug and cable assemblies: see accessories page 181
2. Not available with P10 or for Hazardous location switches
Examples of complete unit catalog numbers with mini or micro connectors in standard plug-in body type
Type of head Catalog number Weight
kg (lb)
Single pole, 5-pin mini connector (7/8"-16 UN-2A thread)
Side plunger 9007C54FY1901 0.57 (1.25)
Top plunger 9007C54DY1901 0.57 (1.25)
9007C54EY1901 0.57 (1.25)
Rotary 9007C54B2Y1901 0.57 (1.25)
Wobble stick 9007C54LY1901 0.57 (1.25)
9007C54JY1901 0.57 (1.25)
Two poles, 9-pin mini connector (1-2/8"-16 UN-2A thread)
Side plunger 9007C62FY19016 0.57 (1.25)
Top plunger 9007C62DY19016 0.57 (1.25)
9007C62EY19016 0.57 (1.25)
Rotary 9007C62B2Y19016 0.57 (1.25)
Wobble stick 9007C62LY19016 0.57 (1.25)
9007C62JY19016 0.57 (1.25)
Single pole, 5-pin micro single key (M12 x 1 thread)
Side plunger 9007C62FY1912 0.57 (1.25)
Top plunger 9007C54DY1912 0.57 (1.25)
9007C54EY1912 0.57 (1.25)
Rotary 9007C54B2Y1912 0.57 (1.25)
Wobble stick 9007C54LY1912 0.57 (1.25)
9007C54JY1912 0.57 (1.25)
Single pole, 5-pin micro connector two keys (1/2’’-20 UNF-2A thread)
Side plunger 9007C54FY19019 0.57 (1.25)
Top plunger 9007C54DY19019 0.57 (1.25)
9007C54EY19019 0.57 (1.25)
Rotary 9007C54B2Y19019 0.57 (1.25)
Wobble stick 9007C54LY19019 0.57 (1.25)
9007C54JY19019 0.57 (1.25)
Y190•
Standard body shown
with Y190• option
2
1
4
3
1
2
4
3
5
6
7
8
Form Y1901, Y1903
Red
Orange
BlackWhite
Green
Orange
Black
Red
White
5, 6 Not
connected
1, 2 Not
connected
Form Y19013
2
1
4
3Black
White
RedOrange
Green
Form Y1905
179
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Factory Modifications (Forms)
Special features and modifications (continued)
Special features do not apply to 9007CR unless noted. Not field installable, except where noted.
Potted limit (position) switch or plug-in receptacle only (1)
Description (2)
Suffix to add to the
device catalog
number
Weight
kg (lb)
With individual
wires
Single pole With five #16 wires five feet long Y1841 0.59 (1.30)
Two pole With nine #16 wires five feet long Y1842 0.60 (1.32)
With STOWA
cord
Single pole With five conductor #16 STOWA cord eight feet long Y1851 1.30 (2.88)
Single pole Same as Y1851 but with different wire color coding Y1855 1.30 (2.88)
Two pole With nine conductor #16 STOWA cord eight feet long Y1852 1.31 (2.90)
Two pole Same as Y1852 but with different wire color coding Y1856 1.31 (2.90)
Tamper proof screws—complete switch only
With individual
wires
Same as Y1841but with tamper proof screws on head and body Y1843 0.59 (1.30)
Same as Y1842 but with tamper proof screws on head and body Y1844 0.60 (1.32)
With STOWA
cord
Same as Y1851 but with tamper proof screws on head and body Y1853 1.30 (2.88)
Same as Y1852 but with tamper proof screws on head and body Y1854 1.30 (2.88)
Same as Y1855 but with tamper proof screws on head and body Y1857 1.31 (2.90)
Same as Y1856 but with tamper proof screws on head and body Y1858 1.31 (2.90)
1. Not for 9007CR Hazardous location devices
2. Wire entry completely sealed with epoxy resin.
Dust boot (protects against abrasive dusts, dirt, grit and sand)
Description
Suffix to add to the
device catalog
number
Weight
kg (lb)
Lever type limit switch furnished with
a boot around the shaft On all 9007C and 9007CR lever type switches Y33 0.01 (0.01)
Dust boot only See accessories, page 181
Wiring Diagrams
Forms Y1851 and Y1853 Forms Y1852 and Y1854 Forms Y1855 and Y1857 Forms Y1856 and Y1858
Y
18••
T
erminal base shown
w
ith Y18•• option
2
1
4
3
26
15
48
37
OrangeRed
BlackWhite
Green
BrownOrange
Ye l l o wRed
Green
BlueBlack
PinkWhite
26
15
48
37
2
1
4
3BlackWhite
RedOrange
Green
BlackYellow
WhiteBrown
Green
BlueRed
PinkOrange
180
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Factory Modifications (Forms)
Special features and modifications (continued)
Special features do not apply to 9007CR unless noted. Not field installable, except where noted.
Optional shafts
Description
Suffix to add to the
device catalog
number
Weight
kg (lb)
Optional shaft, 7.8 mm (0.306 in.) diameter:
To accommodate lever arms from the obsolete Denison C limit switches. Available on all
9007C, CF, or CR limit switches
Y247 0.57 (1.25)
Optional shaft, 7.1 mm (0.28 in.) diameter:
Available on all 9007C, CF, or CR limit switches Y249 0.57 (1.25)
Switch with adapter plate
Description
Suffix to add to the
device catalog
number
Weight
kg (lb)
Switch with adapter plate permitting substitution of any 9007C switch with standard
body for any type T switch with style B base plate Y147 —
Direct acting contacts / Positive opening contacts Y1561
One pole, normally closed, slow make-slow break, direct acting contact mechanism substituted for standard snap switch on
9007C52, C54 and CR53 devices.
This mechanism was designed for use in emergency overtravel applications. The movable contact of this basic switch unit is
acted upon directly by the actuating mechanism of the limit switch and is not dependent upon the force exerted by a snap switch
blade or spring to open the circuit. Because these contacts are slow make-slow break, they are best suited for applications
where they are not actuated during normal operation, but only if abnormal overtravel is encountered.
Electrical contact ratings
AC—NEMA A600
maximum current—35 % power factor DC maximum current
Make Break Continuous
carrying Make or break Continuous
carrying
Volts AVA AVA AVolts AVA A
120 60 7200 6 720 10 125 1.1/0.55 (1) 138/69 (1) 5/2.5 (1)
240 30 7200 3 720 10 — — — —
480 15 7200 1.5 720 10 250 0.27 67.5 2.5
600 12 7200 1.2 720 10 600 0.10 60 2.5
1. 9007C52 compact unit ratings at 125 Vdc—same ratings as 9007C54 and 9007CR53 at other voltages.
Description
Suffix to add to the
device catalog
number
Weight
kg (lb)
Direct acting contact/positive opening contact block (slow break single pole only) Y1561 0.566 (1.25)
181
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Accessories
Accessories
Hub only
Description Catalog number Weight
kg (lb)
Hub can be field installed on any 9007C lever type switch, increasing
the shaft diameter from 0.375–0.749 in. (9.53–19 mm), to accept levers
normally used with 9007T/FT switches.
9007S9 0.02 (0.04)
Dust boot only
Description Catalog number Weight
kg (lb)
Dust boot can be field installed on any 9007C and CR lever type
switch 9007BT3 0.01 (0.01)
Conduit seal insert (field instable)
Description Catalog number Weight
kg (lb)
Conduit seal fits in conduit entrance and excludes liquids
5 hole seal 31032-488-01 0.01 (0.02)
9 hole seal 31032-815-01 0.01 (0.02)
Plug and cable assemblies
Description Catalog number Weight
kg (lb)
5-pin mini connecting cables
(to fit certain switches with Form Y190••)
Plug and 3 ft (0.91 m) cable BH20-5-3 —
Plug and 6 ft (1.83 m) cable BH20-5-6 —
Plug and 12 ft (3.66 m) cable BH20-5-12 —
Note: Other cables available. See the Machine Cabling section of the Sensors catalog, 9006CT0101.
Adapter—Field installable
Description Catalog number Weight
kg (lb)
Adapter plate kit only
Plate plus mounting screws for substitution of any 9007C switch with
standard box for any 9007T switch with style B base plate
9007BT1 0.23 (0.50)
Adapter plate
for direct substitution of any 9007C plunger switches for 9007B plug-in
plunger switches—use only if there is a problem in lining up cam tracks
Standard body type 9007CT10 (1) 0.13 (0.28)
Compact body type 9007CT13 (2) 0.01 (0.20)
Adapter plate kit
permitting direct substitution of any 9007C lever arm switch with
standard box for any 9007AW lever arm switch
9007CT11 0.23 (0.50)
20 mm conduit connection adapter
male 0.5 in. (12.7 mm) NPT on one end,
female 0.787 in. (20 mm) on other end
9007CT12 0.01 (0.20)
1. Dimensions: 0.22 x 2.94 x 1.54 in. (5.6 x 75 x 39 mm)
2. Dimensions: 0.22 x 2.07 x 1.54 in. (5.6 x 53 x 39 mm)
182
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Dimensions—Standard Body
Side Plunger
9007C••F 9007C••G 9007C••GD 9007C••H
Dual dimensions:
1. 2 x 0.20/5 x 0.22/6 HLS.
2. 2 x 10-24 Tapped HLS Back Mtg 0.29/7 DP.
3. 1/2 14 NPT.
4. Adjustable.
Top Plunger
9007C••D 9007C••E 9007C••ED
Dual dimensions:
1. 2 x 0.20/5 x 0.22/6 HLS.
2. 2 x 10-24 Tapped HLS Back Mtg 0.29/7 DP.
3. 1/2 14 NPT.
4. Adjustable.
0.63
19
0.75
15
0.58
(3)
20
0.78
3
0.12
Ø
16
48
1.88
67
2.63
(2)
(1)
31
1.24
60
2.35
30
1.17
1.55
39
102
4.02
0.64
16
1.79
45
20
0.78
36
19
0.75
15
0.58 Ø
9
0.37
1.41
55
2.16
31
1.24
60
2.35
30
1.17
1.55
39
102
4.02
0.64
16
1.79
(3)
45
(2)
(1)
13
0.50
0.19
5
1.96
50
69
2.71
31
1.24
19
0.75
30
1.17
60
2.35
1.55
15
0.58
102
4.02
0.64
16
1.79
(3)
20
0.78
4539
(2)
(1)
(4)
Min.
Min.
1.24
20
19
0.75
30
1.17
60
2.35
1.55
15
0.58
9
0.37
Ø
43 37
1.68 1.44
79
3.12
31
39
0.78
102
4.02
0.64
16
1.79
(3)
45
(2)
(1)
in.
mm
20
0.78
0.63
16
56
2.19
(3)
119
4.66
0.64
16
1.79
45
3
0.12
Ø15
0.58
48
60
2.35
1.88
30
1.17
1.55
39
(2)
(1)
Ø
9
0.36
44
1.72
15
0.58
60
2.35
30
1.17
1.55
39
20
0.78
115
4.50
0.64
16
1.79
45
(2)
(1)
(3)
1.17
13
0.50
133
5.22
57
2.25
5
0.19 15
0.58
60
2.35
30
1.55
39
20
0.78
0.64
16
1.79
45
(2)
(1)
(3)
(4)
in.
mm
183
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Dimensions—Standard Body
Rotary
9007C•••• A, B, C, N, T5, T10
Dual dimensions:
1. 2 x 0.20/5 x 0.22/6 HLS.
2. 2 x 10-24 Tapped HLS Back Mtg 0.29/7 DP.
3. 1/2 14 NPT.
Wobble stick
9007C••JKC 9007C••J
9007C••K 9007C••KC 9007C••L
Dual dimensions:
1. 2 x 0.20/5 x 0.22/6 HLS.
2. 2 x 10-24 Tapped HLS Back Mtg 0.29/7 DP.
3. 1/2 14 NPT.
Ø
11
0.44
19
0.75
15
0.58
(3)
31
1.24
60
2.35
30
1.17
1.55
39
102
4.02
0.64
16
1.79
45
1.72
44
2.50
64
(2)
(1)
in.
mm
20
0.78
(3)
126
4.94
0.64
16
1.79
45
6
0.25
46
1.80
15
0.58
55
60
2.35
2.16
30
1.17
1.55
39
Ø
(2)
(1)
20
0.78
(3)
211
8.28
0.64
16
1.79
45
140
5.50
15
0.58
76
60
2.35
3.00
30
1.17
1.55
39
6
0.25
Ø
(2)
(1)
84
3.30
13.30
2
0.08
338
16.08
409
Ø
15
0.58
60
2.35
30
1.17
1.55
39
20
0.78
(3)
0.64
16
1.79
45
(2)
(1)
20
0.78
(3)
207
8.14
0.64
16
1.79
45
136
5.36
15
0.58
60
2.35
30
1.17
1.55
39
(2)
(1)
10
0.38
20
0.78
(3)
231
9.07
0.64
16
1.79
45
160
6.29
15
0.58
58
60
2.35
2.28
30
1.17
1.55
39
2
0.07
Ø
(2)
(1)
in.
mm
184
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Dimensions—Compact Body
Side Plunger
9007C52F 9007C52G 9007C52GD 9007C52H
Dual dimensions:
1. 2 x 0.20/5 HLS.
2. 2 x 10-24 Tapped HLS Back Mtg 0.20/5 DP.
3. 1/2 14 NPT.
4. Adjustable.
Top Plunger
9007C52D 9007C52E 9007C52ED
Dual dimensions:
1. 2 x 0.20/5 HLS.
2. 2 x 10-24 Tapped HLS Back Mtg 0.20/5 DP.
3. 1/2 14 NPT.
4. Adjustable.
0.63
19
0.75
15
0.58 20
0.78
3
0.12
Ø
16
48
1.88
67
2.63
31
1.24
37
1.47 80
3.14
30
1.17
1.55
39
(2)
(1)
(3)
0.64
16
1.79
45
80
3.14
20
0.78
36
19
0.75
15
0.58 Ø
9
0.36
1.41
55
2.16
31
1.24
37
1.47
30
1.17
1.55
39
(2)
(1)
(3)
0.64
16
1.79
45
80
3.1
4
13
5
0.50
0.19
1.96
50
69
2.71
19
0.75
15
0.58
20
0.78
(3)
0.64
16
1.79
45
31
1.24
37
1.47
30
1.17
1.55
39
(2)
(1)
(4)
Min.
Min.
1.24
80
3.14
20
19
0.75
15
0.58 9
0.37
Ø
43 37
1.68 1.44
79
3.12
31
0.78
(3)
0.64
16
1.79
45
37
1.47
30
1.17
1.55
39
(2)
(1)
in.
mm
20
0.78
0.63
16
56
2.19
97
3.78
3
0.12
Ø15
0.58
48
1.88
37
1.47
30
1.17
1.55
39
(2)
(1)
(3)
0.64
16
1.79
45
Ø
9
0.36
44
1.72
15
0.58
20
0.78
93
3.62
37
1.47
30
1.17
1.55
39
(2)
(1)
(3)
0.64
16
1.79
45
13
0.50
105
4.15
57
2.25
5
0.19 15
0.58
20
0.78
37
1.47
30
1.17
1.55
39
(2)
(1)
(3)
0.64
16
1.79
45
(4)
in.
mm
185
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Dimensions—Compact Body
Rotary
9007C52•• A, B, C, N, T5, T10
Dual dimensions:
1. 2 x 0.20/5 x 0.22/6 HLS.
2. 2 x 10-24 Tapped HLS Back Mtg 0.29/7 DP.
3. 1/2 14 NPT.
Wobble stick
9007C52JKC 9007C52J
9007C52K 9007C52KC 9007C52L
Dual dimensions:
1. 2 x 0.20/5 x 0.22/6 HLS.
2. 2 x 10-24 Tapped HLS Back Mtg 0.29/7 DP.
3. 1/2 14 NPT.
Ø
11
0.44
19
0.75
15
0.58
31
1.24
80
3.14
1.72
44
2.50
64
37
1.47
30
1.17
1.55
39
(2)
(1)
(3)
0.64
16
1.79
45
in.
mm
20
0.78
104
4.06
6
0.25
46
1.80
15
0.58
55
2.16
37
1.47
30
1.17
1.55
39
(2)
(1)
(3)
0.64
16
1.79
45
20
0.78
189
7.40
140
5.50
15
0.58
76
3.00
6
0.25
(3)
0.64
16
1.79
45
37
1.47
30
1.17
1.55
39
(2)
(1)
84
3.30
13.30
2
0.08
338
15.2
386
15
0.58
20
0.78
(3)
0.64
16
1.79
45
37
1.47
30
1.17
1.55
39
(2)
(1)
184
7.26
(3)
0.64
16
1.79
45
37
1.47
30
1.17
1.55
39
(2)
(1)
136
5.36
15
0.58 20
0.78
10
0.38
20
0.78
209
8.19
160
6.29
15
0.58
58
2.28
2
0.07
(3)
0.64
16
1.79
45
30
1.17
1.55
39
(2)
(1)
37
1.47
in.
mm
186
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Adaptable Sub-Assemblies
9007 CT54 9007 CT62
9007 CT52
9007 D 9007 F 9007 JKC 9007 KC
9007 E 9007 ED 9007 J
9007 R + mushroom button 9007 GD
9007 H 9007 G 9007 K 9007 L
9007 CO54 9007 CO62 9007 CO52
187
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Adaptable Sub-Assemblies
9007
A, B, C, N, T5, T10
9007 MA11 9007 HA1 9007 FA1 9007 EA1 9007 FA6 9007 LA19
9007 AA1 9007 LA4 9007 KB11 9007 CA11
9007 BA3 9007 KA11 9007 HA21 9007 RA11 9007 HA23
188
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Adaptable Sub-Assemblies
Body with contacts for plunger or rotary heads
Plug-in Unit (Top) with contacts
Type Type of contact Function diagram Catalog number Weight
kg (lb)
For standard
plug-in body type
Single pole 9007CO54 0.19 (0.42)
Two p o l e 9007CO62 0.20 (0.44)
Two stage 9007CO66 0.23 (0.50)
Neutral position 9007CO68 0.20 (0.45)
For compact
plug-in body type Single pole 9007CO52 0.18 (0.40)
Plug-in Receptacle (Base) with screw terminals (1)
Type Type of contact Function diagram Catalog number Weight
kg (lb)
For standard
plug-in body type
Single pole 9007CT54 0.22 (0.48)
Two p o l e 9007CT62 0.22 (0.48)
Neutral position 9007CT62 0.22 (0.48)
Two stage 9007CT62 0.22 (0.48)
Reed switches,
either N/O
or N/C (2)
9007CT54 0.22 (0.48)
For compact
plug-in body type Single pole 9007CT52 0.15 (0.34)
1. Acceptable wire sizes: 12-22 AWG (2.05 mm2-0.644mm2).
Recommended terminal clamp torque: 7 lb-in (0.80 N•m).
2. Reed switches: plug-in switches less heads are not available as separate units.
Order complete plug-in unit with a head. Example: 9007C084B2.
34
12
9007CO54
DF563880
3
4
2
1
7
8
6
5
9007CO62
DF563881
3
4
2
1
7
8
6
5
3
4
2
1
7
8
6
5
34
12
34
12
9007CT54
DF563882
3
4
2
1
7
8
6
5
9007CT62
DF563883
3
4
2
1
7
8
6
5
3
4
2
1
7
8
6
5
34
12
34
12
Dimensions:
page 196
189
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Adaptable Sub-Assemblies
Heads for linear, rotary and multi-directional movements
Side plunger heads
Type of operator Catalog number Weight
kg (lb)
Side roller plunger, spring return, vertical roller (1) 9007F 0.16 (0.36)
Side push rod plunger, spring return 9007G 0.15 (0.34)
Side push rod plunger, adjustable spring return 9007GD 0.16 (0.36)
Side push rod plunger, maintained contact 9007H 0.16 (0.36)
Top plunger heads
Type of operator Catalog number Weight
kg (lb)
Top roller plunger, spring return 9007D 0.12 (0.26)
Top push rod plunger, spring return 9007E 0.11 (0.24)
Top push rod plunger, adjustable spring return 9007ED 0.12 (0.27)
Palm operated turret head without mushroom button
Mushroom button see Accessories (below) 9007R 0.13 (0.28)
Rotary heads (without lever arm type)
Type of operator Type of
direction Catalog number Weight
kg (lb)
Standard pre-travel spring return CW & CCW 9007B 0.19 (0.41)
Low differential spring return CW & CCW 9007A 0.19 (0.41)
Neutral position
Standard pre-travel spring return CW & CCW 9007T10 0.16 (0.36)
Neutral position
Low differential spring return CW & CCW 9007T5 0.16 (0.36)
Extra light operating torque spring return CW & CCW 9007N 0.18 (0.40)
Maintained contact CW (trip)
CCW (reset) 9007C 0.19 (0.41)
Multi-directional head
Type of operator Catalog number Weight
kg (lb)
Universal (2) 9007JKC 0.19 (0.41)
Wobble stick, Delrin® extension (2) 9007J 0.20 (0.43)
Wobble stick, wire extension (2) 9007K 0.26 (0.57)
Wobble stick, coil spring extension (2) 9007KC 0.22 (0.48)
Cat whisker 9007L 0.17 (0.37)
Accessories
Description Diameter
in. (mm) Color Catalog number Weight
kg (lb)
Mushroom button for palm
operated turret head
1.38 (35)
Black 2358C6G3 0.03 (0.06)
Red 2358C6G2 0.03 (0.06)
Green 2358C6G6 0.03 (0.06)
Ye l l o w 2358C6G8 0.03 (0.06)
2.25 (57.2)
Black — —
Red 2358C22G3 0.05 (0.10)
Green 2358C22G6 0.05 (0.10)
Ye l l o w 2358C22G8 0.05 (0.10)
Description
(2) Type of extension Catalog number Weight
kg (lb)
Wobble stick extensions for
the universal head
Delrin® extension 9007WJ 0.01 (0.03)
Wire extension 9007WK 0.01 (0.02)
Coil spring extension 9007WKC 0.02 (0.04)
1. Field convertible to horizontal.
2. Acceptable wire sizes: 12-22 AWG (2.05 mm2-0.644mm2).
Recommended terminal clamp torque: 7 lb-in (0.80 N•m).
9007F
DF563884
9007GD
DF563885
9007H
DF564138
9007D
DF563886
9007ED
DF563887
9007R + mushroom button
DF563888
9007C
DF563889
9007JKC
DF564139
9007J
DF563890
9007L
DF563891
Dimensions:
page 196
190
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Lever Arms for Rotary Heads
Cast zinc lever arms with standard roller
Lever arms with steel roller (1)
Arm Steel roller
Catalog number Weight
kg (lb)
Length (a)
in. (mm)
Diameter (b)
in. (mm)
Width (c)
in. (mm)
0.88 (22) 0.63 (16) 0.25 (6.3) 9007AA1 0.02 (0.05)
0.63 (16) 9007AA2 0.03 (0.07)
1.38 (35)
0.75 (19) 0.25 (6.3) 9007BA11 0.03 (0.07)
0.63 (16) 9007BA12 0.05 (0.10)
0.63 (16) 0.25 (6.3) 9007BA1 0.03 (0.07)
0.63 (16) 9007BA2 0.04 (0.08)
1.5 (38)
0.75 (19) 0.25 (6.3) 9007MA11 0.03 (0.07)
0.63 (16) 9007MA12 0.05 (0.11)
0.63 (16) 0.25 (6.3) 9007MA1 0.03 (0.06)
0.63 (16) 9007MA2 0.05 (0.10)
2 (51)
0.75 (19) 0.25 (6.3) 9007CA11 0.04 (0.08)
0.63 (16) 9007CA12 0.05 (0.12)
0.63 (16) 0.25 (6.3) 9007CA1 0.04 (0.08)
0.63 (16) 9007CA2 0.05 (0.10)
2.5 (63.5)
0.75 (19) 0.25 (6.3) 9007DA11 0.05 (0.10)
0.63 (16) 9007DA12 0.06 (0.13)
0.63 (16) 0.25 (6.3) 9007DA1 0.04 (0.08)
0.63 (16) 9007DA2 0.05 (0.11)
3 (76)
0.75 (19) 0.25 (6.3) 9007EA11 0.05 (0.10)
0.63 (16) 9007EA12 0.06 (0.14)
0.63 (16) 0.25 (6.3) 9007EA1 0.04 (0.09)
0.63 (16) 9007EA2 0.06 (0.14)
Lever arms with nylon roller
Arm Nylon roller
Catalog number Weight
kg (lb)
Length (a)
in. (mm)
Diameter (b)
in. (mm)
Width (c)
in. (mm)
0.88 (22) 0.63 (16) 0.25 (6.3) 9007AA8 0.02 (0.05)
0.63 (16) 9007AA17 0.03 (0.07)
1.38 (35)
0.75 (19) 0.25 (6.3) 9007BA18 0.03 (0.07)
0.63 (16) 0.25 (6.3) 9007BA8 0.05 (0.10)
0.63 (16) 9007BA17 0.05 (0.11)
1 (25.4) 0.25 (6.3) 9007BA4 0.03 (0.06)
0.63 (16) 9007BA13 0.05 (0.10)
1.5 (38)
0.75 (19) 0.25 (6.3) 9007MA18 0.03 (0.06)
0.63 (16) 0.25 (6.3) 9007MA8 0.05 (0.10)
0.63 (16) 9007MA17 0.05 (0.10)
1 (25.4) 0.25 (6.3) 9007MA4 0.05 (0.10)
0.63 (16) 9007MA13 0.05 (0.12)
2 (51)
0.75 (19) 0.25 (6.3) 9007CA18 0.05 (0.10)
0.63 (16) 0.25 (6.3) 9007CA8 0.03 (0.06)
0.63 (16) 9007CA17 0.03 (0.07)
1 (25.4) 0.25 (6.3) 9007CA4 0.05 (0.12)
0.63 (16) 9007CA13 0.06 (0.14)
2.5 (63.5)
0.75 (19) 0.25 (6.3) 9007DA18 0.03 (0.07)
0.63 (16) 0.25 (6.3) 9007DA8 0.06 (0.13)
0.63 (16) 9007DA17 0.06 (0.13)
1 (25.4) 0.25 (6.3) 9007DA4 0.06 (0.14)
0.63 (16) 9007DA13 0.07 (0.15)
3 (76)
0.75 (19) 0.25 (6.3) 9007EA18 0.04 (0.08)
0.63 (16) 0.25 (6.3) 9007EA8 0.06 (0.14)
0.63 (16) 9007EA17 0.07 (0.16)
1 (25.4) 0.25 (6.3) 9007EA4 0.07 (0.15)
0.63 (16) 9007EA13 0.08 (0.17)
1. Material is hardened, oil-impregnated, sintered iron.
a
c
b
a: Length of lever Arm
b: Roller diameter
c: Roller width
DF563135
9007AA1
DF563899
9007MA11
DF563900
9007CA11
DF531698
9007EA1
DF531684
Dimensions:
page 197
191
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Lever Arms for Rotary Heads
Cast zinc lever arms (continued)
Lever arms with ball bearing roller
Arm Ball bearing roller
Catalog number Weight
kg (lb)
Length (a)
in. (mm)
Diameter (b)
in. (mm)
Width (c)
in. (mm)
0.88 (22) 0.69 (17.5) 0.25 (6.3) 9007AA9 0.04 (0.09)
1.38 (35) 0.69 (17.5) 0.25 (6.3) 9007BA9 0.04 (0.09)
1.5 (38) 0.69 (17.5) 0.25 (6.3) 9007MA9 0.04 (0.09)
2 (51) 0.69 (17.5) 0.25 (6.3) 9007CA9 0.04 (0.09)
2.5 (63.5) 0.69 (17.5) 0.25 (6.3) 9007DA9 0.04 (0.09)
3 (76) 0.69 (17.5) 0.25 (6.3) 9007EA9 0.04 (0.09)
Lever arms with roller on opposite side to standard
Lever arm Roller on opposite side
Catalog number Weight
kg (lb)
Length (a)
in. (mm)
Diameter (b)
in. (mm)
Width (c)
in. (mm)
0.88 (22) 0.63 (16) 0.25 (6.3) 9007AA5 0.04 (0.09)
0.63 (16) 0.63 (16) 9007AA6 0.04 (0.09)
1.38 (35)
0.75 (19) 0.25 (6.3) 9007BA15 0.04 (0.09)
0.63 (16) 0.25 (6.3) 9007BA5 0.04 (0.09)
0.63 (16) 0.63 (16) 9007BA6 0.04 (0.09)
1.5 (38)
0.75 (19) 0.25 (6.3) 9007MA15 0.04 (0.09)
0.63 (16) 0.25 (6.3) 9007MA5 0.04 (0.09)
0.63 (16) 0.63 (16) 9007MA6 0.04 (0.09)
2 (51)
0.75 (19) 0.25 (6.3) 9007CA15 0.04 (0.09)
0.63 (16) 0.25 (6.3) 9007CA5 0.04 (0.09)
0.63 (16) 0.63 (16) 9007CA6 0.04 (0.09)
2.5 (63.5)
0.75 (19) 0.25 (6.3) 9007DA15 0.04 (0.09)
0.63 (16) 0.25 (6.3) 9007DA5 0.04 (0.09)
0.63 (16) 0.63 (16) 9007DA6 0.04 (0.09)
3 (76)
0.75 (19) 0.25 (6.3) 9007EA15 0.04 (0.09)
0.63 (16) 0.25 (6.3) 9007EA5 0.04 (0.09)
0.63 (16) 0.63 (16) 9007EA6 0.04 (0.09)
Lever arms with roller countersunk roller pin
Arm Roller (countersunk roller pin)
Catalog number Weight
kg (lb)
Length (a)
in. (mm)
Diameter (b)
in. (mm)
Width (c)
in. (mm)
1.5 (38) 0.75 (19) 0.25 (6.3) 9007MA31 0.03 (0.07)
2 (51) 0.75 (19) 0.25 (6.3) 9007CA31 0.04 (0.08)
2.5 (63.5) 0.75 (19) 0.25 (6.3) 9007DA31 0.04 (0.09)
Lever arms with cable operated with eyebolt (I.D.) instead of roller
Arm Cable
Catalog number Weight
kg (lb)
Length
in. (mm)
Length
in. (mm)
1.5 (38) 0.38 (9.6) 9007MA22 0.05 (0.10)
a
c
b
a: Length of lever Arm
b: Roller diameter
c: Roller width
DF563135
Dimensions:
page 197
192
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Lever Arms for Rotary Heads
Flat steel lever arms with standard roller (1)
Arm Roller
Catalog number Weight
kg (lb)
Length(a)
in. (mm)
Diameter (b)
in. (mm)
Width (c)
in. (mm)
Lever arms with steel roller
0.88 (22) 0.63 (16) 0.25 (6.3) 9007AA1S 0.01 (0.03)
0.63 (16) 0.63 (16) 9007AA2S 0.01 (0.03)
1.38 (35) 0.63 (16) 0.25 (6.3) 9007BA1S 0.01 (0.03)
0.63 (16) 0.63 (16) 9007BA2S 0.01 (0.03)
2 (51) 0.63 (16) 0.25 (6.3) 9007CA1S 0.03 (0.07)
0.63 (16) 0.63 (16) 9007CA2S 0.04 (0.08)
2.5 (63.5) 0.63 (16) 0.25 (6.3) 9007DA1S 0.04 (0.08)
0.63 (16) 0.63 (16) 9007DA2S 0.04 (0.08)
3 (76) 0.63 (16) 0.25 (6.3) 9007EA1S 0.04 (0.08)
0.63 (16) 0.63 (16) 9007EA2S 0.04 (0.08)
Lever arms with nylon roller
1.38 (35) 1 (25.4) 0.25 (6.3) 9007BA4S 0.01 (0.03)
1.5 (38) 0.75 (19) 0.25 (6.3) 9007MA18S 0.01 (0.03)
2 (51) 1 (25.4) 0.25 (6.3) 9007CA4S 0.03 (0.07)
2.5 (63.5) 1 (25.4) 0.25 (6.3) 9007DA4S 0.04 (0.08)
3 (76) 1 (25.4) 0.25 (6.3) 9007EA4S 0.04 (0.08)
Lever arms without roller
0.88 (22) ——9007AA0S
1.38 (35) ——9007BA0S 0.01 (0.02)
2 (51) ——9007CA0S 0.03 (0.06)
2.5 (63.5) ——9007DA0S 0.03 (0.07)
3 (76) 9007EA0S 0.03 (0.07)
1. Material is hardened, oil-impregnated, sintered iron.
90° Forked cast zinc lever arms
Arm Roller
position
Roller
Catalog number Weight
kg (lb)
Length(a)
in. (mm)
Diameter(b)
in. (mm)
Width(c)
in. (mm)
Lever arms with steel roller
1.5 (38)
Rollers on same side 0.75 (19) 0.25 (6.3) 9007LA4 0.05 (0.12)
0.63 (16) 0.25 (6.3) 9007LA1 0.07 (0.15)
R.H. Roller on
opposite side
0.75 (19) 0.25 (6.3) 9007LA5 0.05 (0.12)
0.63 (16) 0.25 (6.3) 9007LA2 0.07 (0.15)
L.H. Roller on
opposite side
0.75 (19) 0.25 (6.3) 9007LA6 0.05 (0.12)
0.63 (16) 0.25 (6.3) 9007LA3 0.07 (0.15)
Lever arms with nylon rollers
1.5 (38)
Rollers on same side 0.75 (19) 0.25 (6.3) 9007LA16 0.04 (0.09)
1 (25.4) 9007LA10 0.06 (0.14)
R.H. Roller on
opposite side 0.75 (19) 0.25 (6.3) 9007LA17 0.04 (0.09)
1 (25.4) 9007LA11 0.06 (0.14)
L.H. Roller on
opposite side 0.75 (19) 0.25 (6.3) 9007LA18 0.04 (0.09)
1 (25.4) 9007LA12 0.06 (0.14)
Lever arms with ball bearing rollers
1.5 (38)
Rollers on same side 0.69 (17.5) 0.25 (6.3) 9007LA7 0.11 (0.25)
R.H. Roller on
opposite side 0.69 (17.5) 0.25 (6.3) 9007LA8 0.11 (0.25)
L.H. Roller on
opposite side 0.69 (17.5) 0.25 (6.3) 9007LA9 0.11 (0.25)
a
c
b
a: Length of lever Arm
b: Roller diameter
c: Roller width
DF563135
9007LA4
DF531692
Dimensions:
page 197
193
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Lever Arms for Rotary Heads
One-way lever arm
Arm Steel roller
Catalog number Weight
kg (lb)
Length (a)
in. (mm)
Diameter (b)
in. (mm)
Width (c)
in. (mm)
Lever arm with standard roller
1.5 (38) 0.75 (19) 0.25 (6.3) 9007RA11 0.05 (0.12)
Lever arm with nylon roller
1.5 (38) 0.75 (19) 0.25 (6.3) 9007RA18 0.05 (0.12)
Lever arm with ball bearing roller
1.5 (38) 0.69 (17.5) 0.25 (6.3) 9007RA9 0.05 (0.12)
Lever arm with rod type
5 (127) ——9007FA2 0.05 (0.12)
One-way cast zinc roller lever arm
Arm Roller
Catalog number Weight
kg (lb)
Length(a)
in. (mm)
Diameter(b)
in. (mm)
Width(c)
in. (mm)
Cast arm with steel roller
1.38 (35) 1.25 (32) 0.25 (6.3) 9007BA3 0.07 (0.15)
1.5 (38) 1.25 (32) 0.25 (6.3) 9007MA3 0.10 (0.23)
2 (51) 1.25 (32) 0.25 (6.3) 9007CA3 0.12 (0.27)
2.5 (63.5) 1.25 (32) 0.25 (6.3) 9007DA3 0.12 (0.27)
3 (76) 1.25 (32) 0.25 (6.3) 9007EA3 0.13 (0.29)
Flat steel arm with steel roller
1.38 (35) 1.25 (32) 0.25 (6.3) 9007BA3S 0.07 (0.15)
2 (51) 1.25 (32) 0.25 (6.3) 9007CA3S 0.10 (0.23)
2.5 (63.5) 1.25 (32) 0.25 (6.3) 9007DA3S 0.12 (0.27)
3 (76) 1.25 (32) 0.25 (6.3) 9007EA3S 0.13 (0.29)
Offset type cast zinc lever arm
Offset lever arm Roller
Catalog number Weight
kg (lb)
Length in. (mm) Offset Diameter
in. (mm)
Width
in. (mm)
Offset cast zinc arm with steel roller
2 (51) 0.44 (11)
0.63 (16) 0.25 (6.3) 9007KA1 0.04 (0.08)
0.63 (16) 0.63 (16) 9007KA2 0.04 (0.08)
0.75 (19) 0.25 (6.3) 9007KA11 0.04 (0.09)
0.75 (19) 0.63 (16) 9007KA12 0.05 (0.12)
1.5 (38) 0.88 (22) 0.75 (19) 0.25 (6.3) 9007KB11 0.04 (0.10)
0.75 (19) 0.25 (6.3) 9007KB15 0.04 (0.10)
Offset cast zinc arm with ball bearing roller
2 (51) 0.44 (11) 0.69 (17.5) 0.25 (6.3) 9007KA9 0.04 (0.10)
Offset cast zinc arm with nylon roller
2 (51) 0.44 (11) 0.75 (19) 0.25 (6.3) 9007KA18 0.04 (0.10)
0.75 (19) 1 (25.4) 9007KA21 0.04 (0.10)
a
c
b
a: Length of lever Arm
b: Roller diameter
c: Roller width
DF563135
9007RA11
DF531694
9007BA3
DF531683
9007KB11
DF531691
9007KA11
DF531690
Dimensions:
page 197
194
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Lever Arms for Rotary Heads
Adjustable length lever arm
Lever arm Roller
Catalog number Weight
kg (lb)
Dimensions length(a)
in. (mm)
Diameter (b)
in. (mm)
Width (c)
in. (mm)
Adjustable length arm with steel roller
Non-bendable, adjustable from
0.88 (22) to 4 (101)
0.63 (16) 0.25 (6.3) 9007HA1 0.05 (0.12)
0.63 (16) 0.63 (16) 9007HA2 0.07 (0.14)
Bendable, adjustable
from 0.88 (22) to 4 (101)
0.63 (16) 0.25 (6.3) 9007HA5 0.06 (0.14)
0.63 (16) 0.63 (16) 9007HA6 0.04 (0.18)
Adjustable length arm with nylon roller
Non-bendable, adjustable
from 0.88 (22) to 4 (101)
0.63 (16) 0.25 (6.3) 9007HA4 0.05 (0.12)
1 (25.4) 0.63 (16) 9007HA22 0.06 (0.13)
Bendable, adjustable
from 0.88 (22) to 4 (101)
0.63 (16) 0.25 (6.3) 9007HA8 0.06 (0.14)
1.0 (16) 0.63 (16) 9007HA23 0.07 (0.16)
2 (51) 0.25 (6.3) 9007HA26 0.08 (0.17)
Adjustable length arm with ball bearing roller
Non-bendable, adjustable
from 0.88 (22) to 4 (101) 0.69 (17.5) 0.25 (6.3) 9007HA24 0.06 (0.13)
Bendable, adjustable
from 0.88 (22) to 4 (101) 0.69 (17.5) 0.25 (6.3) 9007HA25 0.07 (0.16)
Adjustable length arm with ball Delrin® roller
Bendable, adjustable
from 0.88 (22) to 4 (101) 1.63 (41) 0.25 (6.3) 9007HA20 0.07 (0.16)
Adjustable length arm with rubber tire roller
Bendable, adjustable
from 0.88 (22) to 4 (101) 2.13 (54) 0.5 (12.7) 9007HA21 0.10 (0.22)
Adjustable length arm without roller
Non-bendable, adjustable from
0.88 (22) to 4 (101) ——9007HA0 0.15 (0.33)
Bendable, adjustable
from 0.88 (22) to 4 (101) ——9007HA9 0.11 (0.25)
Rod type lever arm
Description Length Catalog number Weight
kg ( lb)
in. (mm)
Rod
Stainless steel rod 10 (254) 9007FA1 0.07 (0.15)
Spring rod, steel 12 (304) 9007FA3 0.07 (0.15)
Spring rod, Delrin®12 (304) 9007FA5 0.07 (0.15)
Looped Delrin rod arm —9007FA6 0.05 (0.11)
90° forked rod
Spring rods, steel 2.5 (63.5) 9007LA19 0.06 (0.13)
d
e
a
f
c
b
a: Length of lever Arm
b: Roller diameter
c: Roller width
d, e, f: see page 197
DF56313
6
9007HA1
DF531687
9007HA23
DF531689
9007HA21
DF531688
9007FA6
DF531687
9007FA1
DF531687
9007LA19
DF531697
Dimensions:
page 197
195
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Lever Arms for Rotary Heads
360° angular adjustable lever arm
360° angular adjustable lever
arm Roller
Catalog number Weight
kg (lb)
Length (a)
in. (mm)
Roller (1)
position
Diameter (b)
in. (mm)
Width (c)
in. (mm)
Lever arms with steel roller
0.88 (22)
Roller outside 0.63 (16) 0.25 (6.3) 9007AA1M 0.09 (0.20)
Roller inside 0.63 (16) 0.25 (6.3) 9007AA5M 0.09 (0.20)
Roller outside 0.75 (19) 0.25 (6.3) 9007AA11M 0.09 (0.20)
1.38 (35)
Roller outside 0.63 (16) 0.25 (6.3) 9007BA1M 0.09 (0.22)
Roller inside 0.63 (16) 0.25 (6.3) 9007BA5M 0.10 (0.22)
Roller outside 0.75 (19) 0.25 (6.3) 9007BA11M 0.10 (0.22)
1.5 (38)
Roller outside 0.63 (16) 0.25 (6.3) 9007MA1M 0.11 (0.24)
Roller inside 0.63 (16) 0.25 (6.3) 9007MA5M 0.11 (0.24)
Roller outside 0.75 (19) 0.25 (6.3) 9007MA11M 0.11 (0.24)
2 (51)
Roller outside 0.63 (16) 0.25 (6.3) 9007CA1M 0.11 (0.24)
Roller inside 0.63 (16) 0.25 (6.3) 9007CA5M 0.11 (0.24)
Roller outside 0.75 (19) 0.25 (6.3) 9007CA11M 0.11 (0.25)
2.5 (63.5)
Roller outside 0.63 (16) 0.25 (6.3) 9007DA1M 0.11 (0.25)
Roller inside 0.63 (16) 0.25 (6.3) 9007DA5M 0.12 (0.27)
Roller outside 0.75 (19) 0.25 (6.3) 9007DA11M 0.12 (0.27)
3 (76)
Roller outside 0.63 (16) 0.25 (6.3) 9007EA1M 0.12 (0.27)
Roller inside 0.63 (16) 0.25 (6.3) 9007EA5M 0.12 (0.27)
Roller outside 0.75 (19) 0.25 (6.3) 9007EA11M 0.13 (0.29)
Lever arms with nylon roller
0.88 (22) Roller outside 0.63 (16) 0.25 (6.3) 9007AA8M 0.09 (0.20)
0.75 (19) 0.25 (6.3) 9007AA18M 0.09 (0.20)
1.38 (35) Roller outside 0.63 (16) 0.25 (6.3) 9007BA8M 0.11 (0.25)
0.75 (19) 0.25 (6.3) 9007BA18M 0.11 (0.25)
1.5 (38) Roller outside 0.63 (16) 0.25 (6.3) 9007MA8M 0.10 (0.23)
0.75 (19) 0.25 (6.3) 9007MA18M 0.11 (0.25)
2 (51) Roller outside 0.63 (16) 0.25 (6.3) 9007CA8M 0.12 (0.27)
0.75 (19) 0.25 (6.3) 9007CA18M 0.12 (0.27)
2.5 (63.5) Roller outside 0.63 (16) 0.25 (6.3) 9007DA8M 0.12 (0.27)
0.75 (19) 0.25 (6.3) 9007DA18M 0.12 (0.27)
3 (76) Roller outside 0.63 (16) 0.25 (6.3) 9007EA8M 0.12 (0.26)
0.75 (19) 0.25 (6.3) 9007EA18M 0.12 (0.27)
Lever arms with ball bearing roller
0.88 (22) Roller outside 0.69 (17.5) 0.25 (6.3) 9007AA9M 0.10 (0.23)
1.38 (35) Roller outside 0.69 (17.5) 0.25 (6.3) 9007BA9M 0.11 (0.24)
1.5 (38) Roller outside 0.69 (17.5) 0.25 (6.3) 9007MA9M 0.19 (0.26)
2 (51) Roller outside 0.69 (17.5) 0.25 (6.3) 9007CA9M 0.19 (0.26)
2.5 (63.5) Roller outside 0.69 (17.5) 0.25 (6.3) 9007DA9M 0.12 (0.27)
3 (76) Roller outside 0.69 (17.5) 0.25 (6.3) 9007EA9M 0.13 (0.28)
1. Roller can be changed in the field from roller outside to roller inside position or vice versa.
a
b
f
ce
d
a: Length of lever Arm
b: Roller diameter
c: Roller width
d, e: see page 197
Dimensions:
page 197
196
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Bodies and Heads, Dimensions
Body
Standard Compact
Dual dimensions:
1. 2 x 0.20/5 x 0.22/6 HLS.
2. 2 x 10-24 Tapped HLS Back Mtg 0.29/7
DP.
3. 1/2 14 NPT.
Dual dimensions:
1. 2 x 0.20/5 HLS.
2. 2 x 10-24 Tapped HLS Back Mtg 0.20/5
DP.
3. 1/2 14 NPT.
Side plunger heads
9007F 9007G 9007GD 9007H
Top plunger heads
9007D 9007E 9007ED
1. Adjustable
Rotary heads Multi-directional heads
9007C 9007JKC 9007J 9007KC
Multi-directional heads (continued)
9007K 9007L
15
0.58
(3)
20
0.78
(2)
(1)
60
2.35
30
1.17
1.55
39
0.64
16
1.79
45
9
0.36
in.
mm
15
0.58
9
0.36
20
0.78
37
1.47
30
1.17
1.55
39
(2)
(1)
(3)
0.64
16
1.79
45
in.
mm
0.63
19
0.75 22
0.88
15
0.58 20
0.78
3
0.12
Ø
16
48
1.88
67
2.63
31
1.24
20
0.78
36
19
0.75
15
0.58 Ø
9
0.36
1.41
55
2.16
31
1.24 22
0.88
31
1.24
13
0.5
0.19
1.96
Min.
50
69
2.71 Min.
19
0.75
15
0.58
20
0.78
5
22
0.88
(1)
1.24
20
19
0.75
15
0.58
9
0.37
Ø
43 37
1.68 1.44
79
3.12
31
0.78
22
0.88
1.55
39
20
0.78
0.63
16
56
2.19
3
0.12
Ø15
0.58
48
1.88 46
1.83
1.55
39
Ø
9
0.36
44
1.72
15
0.58
20
0.78
35
1.36
1.55
39
57
2.25
13
0.50
5
0.19 15
0.58
20
0.78
48
1.89
(1)
Ø
11
0.44
19
0.75
15
0.58
31
1.24
1.55
39
1.72
44
2.50
64
22
0.88
1.55
39
20
0.78
6
0.25
46
1.80
15
0.58
55
2.16
Ø
46
1.80
1.55
39
20
0.78
140
5.50
15
0.58
76
3.00
6
0.25
Ø
131
5.14
1.55
39
20
0.78
127
5.00
15
0.58
10
0.38
136
5.36
1.55
39
338
13.30
84
3.30
2
0.08
Ø
15
0.58
20
0.78
329
12.94
1.55
39
20
0.78
15
0.58
58
2.28
2
0.07
Ø
160
6.29 151
5.93
Catalog numbers:
pages 188 and 189
197
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Plug-in Body, Metal
Lever Arms for Rotary Heads, Dimensions
Lever arms
9007AA••, BA••, CA••, DA••, EA••, FA••, KA••, LA••, MA••, RA••
a: Length of lever Arm
b: Roller diameter
c: Roller width
a, b, c: pages 190 to 193
Adjustable length lever arms
9007HA• and 9007HA•••
a: Length of lever arm
b: Roller diameter
c: Roller width
d = 0.38/10
e= 4.38/111
a, b, c: page 194
360° angular adjustable lever arms
9007AA••M, 9007BA••M, 9007CA••M, 9007DA••M, 9007EA••M, 9007MA••M
a: Length of lever Arm
b: Roller diameter
c: Roller width
d = 0.84/21
e = 0.38/10
f = 1.05/27
a, b, c: page 195
Rod type lever arms
9007FA1 9007FA6 9007LA19
c
0.16
3.96
b
a
d
a
e
c
0.34
86
b
a
0.69
17.5
b
0.88
22
f
ce
d
2
53
9
.97 (max)
30
1.19
0.41
10
1.00
25
17
0.67
4
0.16
0.80
20
0.41
10
272
10.72
3.3
0.13
Ø
0.80
20
2.06
52
0.41
10
30
1.19
13
0.52
0.41
10
1.00
25
3.3
0.13
5.5
12.7
65
2.56
0.41
45˚
90˚
10
1.00
25
4.31
109
2.5
63.5
0.78
19.8
0.72
18
0.39
9.9
19
0.75
Ø
17
0.66
Catalog numbers:
pages 190 to 195
198
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Non-Plug-in Body, Metal
Hazardous Location
Hazardous Non-Plug-in Body Type (1) With head for linear movement
side plunger top plunger
Page 200 Page 201
With head for rotary movement (lever) With head for multi-directional movement
1. Factory modifications: see pages 176 to 180. Page 202 Page 203
b Application Information—Hazardous Locations
Classification of hazardous locations
Hazardous locations are those areas that may have flammable gases or combustible dusts present in quantities sufficient to produce an
explosive or ignitable mixture. These gases, dusts, may always be present or may only be present in abnormal situations. The National Electrical
Code (NEC) describes these areas in Articles 500 through 503 and divides them into three types of categories: Class, Group, Division.
•Classes
The Classes (I, II, III) differentiate between the type of hazardous materials: I is for gases,II is for dusts, and III is for fibers.
•Groups
The Groups (A, B, C, D, E, F, and G) further subdivide each class according to the relative explosive force of the materials. Group A
atmosphere is acetylene which has a higher explosive force than Group B (which may contain hydrogen, for example); and Group B has a
higher explosive force than Group D, etc.
•Divisions
The Divisions (1 and 2) refer to the presence of these hazardous gases and dusts. Division 1 areas can have these gases or dusts present at
all times under normal operating conditions in an ignitable concentration. Division 2 areas only have ignitable concentrations of dusts
or gases present during abnormal conditions, such as machine failures or container breakage.
The table below summarizes the classifications described above.
Summary of Classification Chart
Class Division Group
I. Gas
1. Hazard May Exist
May Exist In Atmosphere Under Normal Operating Conditions
A. Acetylene
B. Manufactured Gases Containing Hydrogen
C. Petrochemicals (e.g. ethylene)
D. Petrochemicals (e.g. alcohol)
2. Potential Hazard
A. May be present in atmosphere only
under abnormal circumstances.
A. Acetylene
B. Manufactured Gases Containing Hydrogen
C. Petrochemicals (e.g. ethylene)
D. Petrochemicals (e.g. alcohol)
II. Dust
1. Hazard May Exist
May Exist In Atmosphere Under Normal Operating Conditions
E. Conductive and Combustible Dust (Resistivity y105 ohms/cm)
F. Carbonaceous Dusts (Resistivity >102 ohm/cm but < 108ohm/cm)
G. Non-Conductive Combustible Dust (Resistivity > = 105 ohms/cm)
2. Potential Hazard
A. May be present in atmosphere only under abnormal circumstances. G. Non-Conductive Combustible Dust (Resistivity > = 105 ohms/cm)
III. Fibers 1. Production Areas Easily Ignitable Fibers
2. Handling and Storage Areas Easily Ignitable Fibers
199
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Non-Plug-in Body, Metal
Hazardous Location
Environmental characteristics
Conforming to standards Products NEMA 250, EN 60947-1, EN 60947-5-1, IEC 60947, UL 508, C22-2-14-95, CE conformity documentation
Machine assemblies IEC 60204-1
Product certifications UL, CSA, CE
Protective treatment Epoxy powder coat
Ambient air temperature
(Lever/rotary head)
Operation -20…+185 °F (-29…+85 °C), wider range available
Storage -20…+185 °F (-29…+85 °C), wider range available
Vibration resistance Conforming to IEC 60068-2-6 25 gn (10…150 Hz, 11 ms) (C86F switch good for 18.5g only)
Shock resistance Conforming to IEC 60068-2-27 60 gn (9 ms)
40 gn (9 ms) for reed switch
Electric shock protection Conforming to IEC 61140 Class 0
Degree of protection Conforming to IEC 60529 IP 67
Cable entry or connector Depending on model 1/2-14 NPT, M20 X 1.5, ISO cable entry, 5-pin mini connector, 4-pin micro connector
Materials Bodies, heads, levers Bodies in alluminum, heads in Zamak® zinc alloy, levers and rods in zinc, steel, stainless steel, Delrin® resin.
Contact block characteristics
Rated operational
characteristics hard contacts
-AC Voltage
9007CR53 (single pole) NEMA A600 (Ue = 600 V, Ie = 1.2 A); Ithe = 10 A
9007CR61 (two pole) NEMA A600 (Ue = 600 V, Ie = 1.2 A); Ithe = 10 A
9007CR65
(two pole two stage) NEMA A600 (Ue = 600 V, Ie = 1.2 A); Ithe = 10 A
9007CR67 (two pole neutral) NEMA A600 (Ue = 600 V, Ie = 1.2 A); Ithe = 10 A
Rated operational
characteristics hard contacts
-DC Voltage
9007CR53 (single pole) NEMA Q600 (Ue = 600 V. Ie = 0.1 A); Ithe = 2.5 A
9007CR61 (two pole) NEMA R300 (Ue = 250 V. Ie = 0.11 A); Ithe = 1.0 A
9007CR65
(two pole two stage) NEMA R300 (Ue = 250 V. Ie = 0.11 A); Ithe = 1.0 A
9007CR67 (two pole neutral) NEMA R300 (Ue = 250 V. Ie = 0.11 A); Ithe = 1.0 A
Rated insulation voltage 600 V
Rated Impulse Withstand Voltage 2,500 Vac for 1 minute for CE; 2,200 Vac for 1 minute for UL; and 2,640 Vac for 1 s for CSA
Positive Opening Special Y1561 Special Y1561 (one pole slow break only)
Short Circuit Protection 10 A. Bussman Class CC KTK-R-10 fuse non-time-delay
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Maximum Actuation Speed 50fpm / 90fpm (15.2 m/min / 27.4 m/min) with 45 degree cam angle, levers only
Electrical Durability 1 million operating cycles
Types of contact elements IEC 60947-5-1 NEMA JIS
Form Symbol Description Form Symbol Description Form Symbol Description
A
X
Single break A—3—
Double
break
B
Y
Single break B—2—
Double
break
C—C—1Single break
Za Same
polarity
Z“Same
polarity” only
Double
break
Zb Electrically
separate
200
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Non-Plug-in Body, Metal
Hazardous Location
Type of head Side Plunger (mounting by the body)
Hazardous location non-plug-in body type
Type of operator
Side roller plunger
spring return vertical roller
(1)
Side push rod plunger
spring return
Side push rod plunger
adjustable (2)
spring return
Side push rod plunger
maintained contact
Catalog numbers
1 N.O. 1 N.C. snap action 9007CR53F 9007CR53G 9007CR53GD 9007CR53H
2 N.O. 2 N.C. snap action 9007CR61F
9007CR61G 9007CR61GD 9007CR61H
2 N.O. 2 N.C. Two stage snap action 9007CR65F 9007CR65G 9007CR65GD
Weight, kg (lb) 1.020 (2.25) 1.020 (2.25) 1.020 (2.25) 1.020 (2.25)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation On end
Type of actuation
Pre-travel 2 mm (0.08 in.) 3.6 mm (0.14 in.)
Pre-travel two Stage First stage 2 mm (0.08 in.)
First stage to second stage 0.5 mm (0.02 in.)
Total travel 6.3 mm (0.25 in.)
Differential 0.8 mm (0.03 in.)
Reverse overtravel —
Minimum force or torque 1 pole & 2 pole 4 lb (17.8 N) 7 lb (31.1 N)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability (linear travel of cam) 0.03 mm (0.001 in.) —
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. Can be converted to horizontal roller type in the field. To order horizontal roller version add the letter H at the end of the equivalent vertical roller version type.
2. To lock the nut in the desired position, crimp the slot near the bottom of the nut.
34
12
1-2
3-4
1-2
3-4
0.8
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.8
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.8
2
6.3 mm 0
1-2
3-4
1-2
3-4
3.6
6.3 mm 0
3
4
2
1
7
8
6
50.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0 0.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0 0.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
3.6
6.3 mm 0
3
4
2
1
7
8
6
5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
Dimensions:
pages 204 and 205
201
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Non-Plug-in Body, Metal
Hazardous Location
Type of head Top Plunger (mounting by the body)
Hazardous location non-plug-in body type
Type of operator Top roller plunger
spring return
Top push rod plunger
spring return
Top push rod plunger
adjustable (1)
spring return
Palm operated
(2)
Catalog numbers
1 N.O. 1 N.C. snap action 9007CR53D 9007CR53E 9007CR53ED 9007CR53R (2)
2 N.O. 2 N.C. snap action 9007CR61D 9007CR61E 9007CR61ED 9007CR61R (2)
2 N.O. 2 N.C. Two stage snap action 9007CR65D 9007CR65E 9007CR65ED 9007CR65R (2)
Weight, kg (lb) 1.020 (2.25) 1.020 (2.25) 1.020 (2.25) 1.020 (2.25)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation On end
Type of actuation
Pre-travel 2 mm (0.08 in.)
Pre-travel two Stage First stage 2 mm (0.08 in.)
First stage to second stage 0.3 mm (0.01 in.)
Total travel 6.3 mm (0.25 in.)
Differential 0.5 mm (0.02 in.)
Reverse overtravel —
Minimum force or torque 1 pole & 2 pole 3 lb (13.3 N) 7 lb (31.1 N)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability (linear travel of cam) 0.03 mm (0.001 in.)
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. To lock the nut in the desired position, crimp the slot near the bottom of the nut.
2. Does not include mushroom button. Must be ordered separately see page 189.
34
12
1-2
3-4
1-2
3-4
0.5
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.5
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.5
2
6.3 mm 0
1-2
3-4
1-2
3-4
0.5
2
6.3 mm 0
3
4
2
1
7
8
6
50.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0 0.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0 0.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0 0.8
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2
6.3 mm 0
3
4
2
1
7
8
6
5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5 1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0.8
0
6.3 mm
0.8
2
2.5
Dimensions:
pages 204 and 205
202
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Non-Plug-in Body, Metal
Hazardous Location
Type of head Rotary (lever arm type) (1)
Hazardous location
non-plug-in body type
Type of operator Standard pre-travel
spring return
Low differential
spring return
Neutral position Light operating torque
spring return Maintained contact
Standard pre-travel
spring return
Low differential
spring return
Type of direction CW & CCW (2) CW & CCW (2) CW & CCW CW & CCW CW & CCW (2) CW (trip) CCW (reset)
Catalog numbers
1 N.O. 1 N.C. snap action 9007CR53B2 9007CR53A2 9007CR53N2 9007CR53C
2 N.O. 2 N.C. snap action 9007CR61B2 9007CR61A2 9007CR61N2 9007CR61C
2 N.O. 2 N.C. snap action
Neutral position
9007CR67T10 9007CR67T5
2 N.O. 2 N.C. two stage
snap action 9007CR65B2 9007CR65A2 9007CR65N2
Weight, kg (lb) 1.020 (2.25) 1.020 (2.25) 1.020 (2.25) 1.020 (2.25) 1.020 (2.25) 1.020 (2.25)
Contact operation contact closed contact open
Characteristics (nominal operating data)
Switch actuation By 30° cam
Type of actuation
Pre-travel 10° 5° 10° 5° 10° 45°
Pre-travel two stage
First stage 10° 5° — — 10° —
First stage to second stage 2.5° 1.5° — — 2.5° —
Total travel 90° 90°
Differential 4° 2° 4° 2° 4° —
Reverse overtravel 90° —
Operating torque/force
1 pole & 2 pole 4 lb-in (0.45 N•m) 25 oz-in (0.18 N•m) 3 lb-in (0.34 N•m)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability
(linear travel of cam) 0.05 mm (± 0.002 in. ) 0.03 mm (± 0.001 in.) 0.05 mm (± 0.002 in.) 0.05 mm (± 0.002 in.) 0.05 mm (± 0.002 in.) 0.05 mm (± 0.002 in.)
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. Lever arm type must be ordered separately from page 190 to 193.
2. These devices are factory set to operate the contacts in both the CW and CCW directions. Mode of operation is field convertible to CW
only or CCW only.
To order factory converted devices: For CCW only operation, change the 2 at the end of the Type number to 1 (for example: C54B2
becomes C54B1). For CW only operation, delete the 2 at the end of the Type number (for example, C54B2 becomes C54B).
Mode of operation of the lever arm is easily convertible to clockwise or both.
Simply pull out and rotate the arrow to the letters representing the desired direction—CW, CCW, or CW/CCW.
34
12
1-2
3-4
1-2
3-4
4°
10°
90°0
1-2
3-4
1-2
3-4
2°
5°
90°0
1-2
3-4
1-2
3-4
4°
10°
90°0
1-2
3-4
1-2
3-4
45°
90°0
3
4
2
1
7
8
6
5
10°
4°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90° 0 2°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
5°
90° 0
10°
4°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90° 0
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
45°
90° 0
3
4
2
1
7
8
6
5
10° 0 10°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
4°4°
90°CW
90°CCW
CCW
CW
0
5° 0 5°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2°2°
90°CW
90°CCW
CCW CW
0
3
4
2
1
7
8
6
54°
4°
10° 12.5°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90°
0
5° 6.5°
2°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
2° 90°
0
4°
4°
10° 12.5°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90°
0
C
W
/
C
C
W
C
W
W
/
CW
C
C
C
C
W
Dimensions:
pages 204 and 205
203
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Non-Plug-in Body, Metal
Hazardous Location
Type of head Flexible operator (wobble stick)
Hazardous location
non-plug-in body type
Type of operator Universal (1) Wobble stick
Delrin® extension (1)
Wobble stick wire
extension (1)
Wobble stick coil spring
extension (1) Cat whisker
Catalog numbers
1 N.O. 1 N.C. snap action 9007CR53JKC 9007CR53J 9007CR53K 9007CR53KC 9007CR53L
2 N.O. 2 N.C. snap action 9007CR61JKC 9007CR61J 9007CR61K 9007CR61KC 9007CR61L
2 N.O. 2 N.C. Two stage snap action 9007CR65JKC 9007CR65J 9007CR65K 9007CR65KC 9007CR65L
Weight, kg (lb) 1.020 (2.25) 1.020 (2.25) 1.020 (2.25) 1.020 (2.25) 1.020 (2.25)
Contact operation contact closed
contact open
Characteristics (nominal operating data)
Switch actuation By any moving object from any direction
Type of actuation
Pre-travel 10° (any direction) 20°
Pre-travel two-stage
First stage 10° (any direction) 20°
First stage to second stage 4° 5°
Total travel 90°
Differential 36°
Reverse overtravel —
Operating torque/force
1 pole & 2 pole 3 lb-in (0.34 N•m) 7 oz-in (0.05 N•m)
Terminal wire sizes
(Cabling/Screw Clamp) 1 or 2, 12–22 AWG (2.05–0.644 mm2) wires maximum
Repeatability
(linear travel of cam) —
Cable entry 1/2-14 NPT standard, optional M20 x 1.5 mm for ISO cable entry
1. Wobble stick extensions are available separately for the universal head or as replacements for complete devices (see page 189)
34
12
1-2
3-4
1-2
3-4
3°
10°
90°
0
1-2
3-4
1-2
3-4
3°
10°
90°
0
1-2
3-4
1-2
3-4
3°
10°
90°
0
1-2
3-4
1-2
3-4
3°
10°
90°
0
1-2
3-4
1-2
3-4
6°
20°
90°0
3
4
2
1
7
8
6
5
10°
3°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90° 0
10°
3°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90° 0
10°
3°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90° 0
10°
3°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
90° 0 6°
1-2
3-4
1-2
3-4
5-6
7-8
5-6
7-8
20°
90° 0
3
4
2
1
7
8
6
5
10°
3°
3°
14°
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0
90°
10°
3°
3°
14°
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0
90°
10°
3°
3°
14°
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0
90°
10°
3°
3°
14°
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
0
90° 6°
0 90°
6°
25°20°
1-2
3-4
5-6
7-8
5-6
7-8
1-2
3-4
Dimensions:
pages 204 and 205
204
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Non-Plug-in Body, Metal
Hazardous Location—Dimensions
Side Plunger
9007C••F 9007C••G
9007C••GD 9007C••H
1. 2 x 0.27/7, front Mtg holes.
2. 2 x 0.63/16 1/4-20 DP UNC-2B back mounting holes.
3. 2 x 0.26/7 dia. holes.
4. 2 1/4-20 UNC-2B, both sides 0.32/8 DP.
5. 1/2 or 3/4 NPT.
6. Adjustable.
Dual dimensions:
Top Plunger
9007C••D 9007C••E 9007C••ED
1. 2 x 0.27/7, front Mtg holes.
2. 2 x 0.63/16 1/4-20 DP UNC-2B back mounting holes.
3. 2 x 0.26/7 dia. holes, back Mtg. holes.
4. 2 1/4-20 UNC-2B, both sides 0.32/8 DP.
5. 1/2 or 3/4 NPT.
6. Adjustable.
Dual dimensions:
105
40
1.58
30
1.19
1.1
1,68
4.13 155
6.10
53
2.07
76
3.00
43
69
38
1.5
2.72
53
2.08
28
0.34
9
1.01
26
(1)
(2)
(3)
(4)
(5)
0.63
16
48
1.88
62
3.24
3
0.12 27
1.07
30
1.19
27
1.07
36 9
0.36
1.41
70
2.77
1.1
1,68
4.13 155
6.10
53
2.07
76
3.00
43
105
69
38
1.5
2.72
53
2.08
28
0.34
9
1.01
26
(1)
(2)
(3)
(4)
(5)
40
1.58
1.19
105
0.19
5
1.96
50
69
2.71
13
0.50
1.1
1,68
4.13 155
6.10
53
2.07
76
3.00
43
69
38
1.5
2.72
53
2.08
28
0.34
9
1.01
26
(1)
(6)
(2)
(3)
(4)
(5)
30
1.07
27
40
1.58
43 37
1.68 1.44
79
3.12
9
0.37
1.1
1,68
4.13 155
6.10
53
2.07
76
3.00
43
105
1.07
27
69
38
1.5
2.72
53
2.08
28
0.34
9
1.01
26
(1)
(2)
(3)
(4)
(5)
30
1.19
40
1.58
in.
mm
1.07
2.32
59
67
2.63
69
2.71
19
0.75
1.1
4.13
76
3.00 179
7.05
105
69
38
1.5
2.72
53
2.08
28 0.34
9
1.01
26
(1)
(2)
(3)
(4)
(5)
0.63
16
3
0.12 27 27
105
2.55
65
(2)
9
0.36 19
0.75
1.07
1.1
4.13
167
6.58
76
3.00
2.16
55
69
38
1.5
2.72
53
2.08
28 0.34
9
1.01
26
(1) (3)
(4)
(5)
7.11
180
13
0.50
19
0.75
19
0.75
1.1
4.13
76
3.00
105
3.08
78
2.69
68
69
38
1.5
2.72
53
2.08
28 0.34
9
1.01
26
(1)
(2)
(6)
(3)
(4)
(5)
5
0.19
in.
mm
205
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial—Non-Plug-in Body, Metal
Hazardous Location—Dimensions
Rotary
9007C••••
1. 2 x 0.27/7, front Mtg holes.
2. 2 x 0.63/16 1/4-20 DP UNC-2B back mounting holes.
3. 2 x 0.26/7 dia. holes, back Mtg. holes.
4. 2 1/4-20 UNC-2B, both sides 0.32/8 DP.
5. 1/2 or 1/4 NPT.
Dual dimensions:
Wobble stick
9007C••JKC 9007C••J
9007C••K 9007C••KC 9007C••L
1. 2 x 0.27/7, front Mtg holes.
2. 2 x 0.63/16 1/4-20 DP UNC-2B back mounting holes.
3. 2 x 0.26/7 dia. holes, back Mtg. holes.
4. 2 1/4-20 UNC-2B, both sides 0.32/8 DP.
5. 1/2 or 1/4 NPT.
Dual dimensions:
1.1
30
1.19
1,68
19
0.75
4.13 155
6.10
53
2.07
76
3.00
11
0.44 1.72
44
2.79
71
43
105
69
38
1.5
2.72
53
2.08
28 0.34
9
1.01
26
(1)
(2)
(3)
(4)
(5)
in.
mm
105
19
0.75
57
2.24
66
2.60
6
0.25 27
1.07
1.1
4.13
76
3.00
76
2.99
178
7.02
69
38
1.5
2.72
53
2.08
28 0.34
9
1.01
26
(1)
(2)
(3)
(4)
(5)
263
10.35
6
0.25
88
3.45
151
5.93
161
6.32
19
0.75
1.1
4.13
76
3.00
105
69
38
1.5
2.72
53
2.08
28 0.34
9
1.01
26
(1)
(2)
(3)
(4)
(5)
27
1.07
2
0.08
359
14.13
461
18.16
19
0.75
27
1.07
1.1
4.13
76
3.00
105
13.74
349
3.74
95
69
38
1.5
2.72
53
2.08
28 0.34
9
1.01
26
(1)
(2)
(3)
(4)
(5)
157,2
6.19
260
10.22
19
0.75
27
1.07
1.1
4.13
76
3.00
105
5.80
147
69
38
1.5
2.72
53
2.08
28 0.34
9
1.01
26
(1)
(2)
(3)
(4)
(5)
6
0.25
1
0.04
19
0.75
171
6.72
181
7.11
50
1.97
283
11.4
1.1
4.13
76
3.00
105
69
38
1.5
2.72
53
2.08
28 0.34
9
1.01
26
(1)
(2)
(3)
(4)
(5)
27
1.07
in.
mm
206
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial
Technical Information
Glossary
CCW—Counterclockwise only (for lever types).
CW—Clockwise only (for lever types).
Differential—The movement differential or differential is the distance or angle from the operating
position to the releasing position.
Free or normal position—Free or normal position is the initial position of the actuator when there is
no external force (other than gravity) applied on the actuator.
Neutral position—Lever operated switch with a minimum of two contacts. One contact changes
state only when lever moves CW. The second contact changes state only when the lever moves
CCW. (The center position is the free position.)
Operating position—Operating position is the position of the actuator at which the contacts change
state.
Overtravel—Overtravel is the distance or angle through which the actuator moves when traveling
from the operating position to the overtravel limit position.
Pre-travel—Pre-travel is the distance or angle through which the actuator moves from the free
position to the position at which the contacts change state, the operating position.
Release position—Release position is that position of the actuator at which the contacts change
state from the operated contact position to the normal contact position.
Release torque—Release torque is the value to which the torque on the actuator must be reduced
to allow the contacts to change state from the operated position to the normal contact position.
Actuator-lever—An actuator is the mechanism of the switch or enclosure which, when moved as
intended, will operate the contacts.
Maintained contact limit switch—A maintained contact limit switch is a switch which remains in a
given condition until actuated to another condition, which is also maintained until further actuation.
Momentary contact limit switch—A momentary contact limit switch is a switch which returns from
the operated condition to its free or normal circuit condition when the actuating force is removed.
N.C.—Normally closed contact, when the switch mechanism is at its free or normal position.
N.O.—Normally open contact, when the switch mechanism is at its free or normal position.
Operating torque—Operating torque (force) is the minimum torque (force) value which must be
applied to the actuator to cause the contacts to change state.
Overtravel limit position—Overtravel limit position is that position of the actuator beyond which
further overtravel would cause damage to the switch or actuator.
Repeatability—Repeatability is the ability to consistently maintain the original operating
characteristics. Measured by the difference between the operating position of a new switch and of
the same after 1 million operations.
Total travel—Total travel is the sum of the pre-travel and overtravel.
Travel—Movement of the actuator from its free or normal position when force is applied. (See pre-
travel and over travel.)
531627
Free
position Releasing
position
Movement
differential
Operating
position
Overtravel
limit
position
Overtravel
Total travel
Pretravel
Operating torque
Figure 1: Rotary lever type
531628
Free position
Releasing position
Movement differential
Operating position
Overtravel limit position
Overtravel
Total travel
Pretravel
Operating
force
Figure 2: Linear (or Plunger) type
207
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial
Technical Information
Glossary (continued)
Definition of limit switch terms
There are many terms common to position switches that are not used with other control devices.
Before proceeding further, definitions of the commonly used terms should be understood as these
terms will be used throughout this document.
Limit switch—A device that converts a mechanical motion into an electrical control signal.
Actuator—The mechanism of a limit switch that operates the contacts, i.e., lever arm, plunger,
wobble stick.
Cam—A machine part or component that applies force to the switch actuator causing it to move as
intended. Also known as “dog”.
Cam track dimension—The distance from the switch mounting surface to some point on the roller
or actuator.
Differential—The distance that the limit switch actuator moves, from the trip point to the reset point
of the contacts.
Direct-acting/positive opening contacts—Normally closed contacts that are moved directly by
the operating shaft. They are slow make-slow break contacts and have a shorter life than snap
action contacts due to longer arcing times. In general, these should only be used where movement
of actuator must break welded contacts, as in a crane safety limit switch. (Snap action positive
opening contacts are available in the Telemecanique® XCKJ limit switch.)
Maintained contacts—Contacts that remain in the tripped position until the return travel of the cam
moves the switch actuator back and resets the contacts.
Neutral (free or normal) position limit switch—A lever arm type switch with two sets of contacts.
One set operates when the shaft is rotated clockwise; the other operates when the shaft is rotated
counterclockwise.
Operating force—The force required to move limit switch actuator to cause the contacts to change
state.
Overtravel—The distance that the position switch actuator may move beyond the trip point, (see
figure 5) without damage to the switch.
Pole—The number of moveable contacts in a switching mechanism. A single pole device may be 1
N.O., 1 N.C. or 1 N.O. and 1 N.C. with a single set of moveable contacts is used to bridge those
stationary contacts. A double or two pole switch has two moveable contacts.
Positive break contacts—Normally closed contacts with a special mechanism to ensure opening.
Can be snap acting positive break or direct acting slow make, slow break type. The slow break
direct acting type is not recommended for high cycle applications due to shorter life.
Pre-travel—The distance that the limit switch actuator must move to trip the contacts.
Reed contacts—A mechanism consists of a set of contacts hermetically sealed in a glass envelope
and actuated by a magnet attached to the operator. This sealed construction keeps contaminants
out of the contact area, making the reed switch ideal for low voltage, low current circuits such as
programmable controllers.
Reset point—The position of the actuator at which the contacts return to the normal position.
Snap action contacts—Contacts that move rapidly to open or closed position and are relatively
independent of cam speed. Because of shorter arcing times, snap acting contacts have longer
contact life than slow make and break contacts and should be used where fast moving cams are
encountered or where good repeat accuracy is required.
Spring return—Contacts that return to their original position when the actuating force is removed.
L1 L2
531629
Cam
(dog)
Position
switch
Actuator
level type
shown
Coil
Figure 3—Limit switch
531630
Cam track
Lever inverted
Coil
Figure 4—Cam track dimension
531631
Reset over travel
Figure 5—Contact travel
Pre travel
Initial position Differential
Contacts trip
Reverse
over
travel
Contacts
reset
Over
travel
208
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial
Technical Information
Slow break contacts—The speed of transfer of the moveable contacts is dependent on the speed of the
operator. The amount of travel of the moveable contacts is also dependent on the amount of travel by the
operator. Slow make and break contacts have the same trip and reset points, and do not have the
differential travel common to snap switches.
Snap action contacts—The speed of transfer of the moveable contacts is not dependent on the speed
of the operator. The amount of travel of the moveable contacts is also not dependent on the amount of
travel by the operator. The movement of the moveable contacts are determined by a preset travel, after
this point is reached, the contacts will trip. Snap action contacts have different trip and reset points, the
difference is identified as “differential.”
Flexible operators—Flexible resilient or elastic operators, i.e., wobble sticks, do not ensure direct
opening/positive opening action.
Isolated contacts—Single-pole double-throw (SPDT) contacts with four terminals which have two
isolated contact bars mechanically linked. No polarity restrictions apply. Different (isolated) power
supplies can also be applied.
Same polarity—Single-pole double throw (SPDT) contacts with four terminals that require the supply to
be applied with the same polarity (i.e., L1 or +) on the same side of the contact bar. Two different
supplies are not allowed in this configuration. (The loads should always be on the same side of the
contact bar.)
Direct opening contact (also known as positive opening contacts)—A normally closed contact
element coupled with the switch actuator via a non-resilient (non-elastic) member so that full contact
opening is obtained when the actuator is moved through the direct opening travel by applying a direct
opening force. The contact element will shear open in the event of sticking contacts or broken springs.
Proper fusing of the control circuit is required. Direct opening contacts meet IEC 60947-5-1
requirements.
Direct opening travel (also known as positive opening travel)—Minimum travel from the actuator
free position to the position where the direct opening operation is completed. Usually longer than the
normal pre-travel.
Reed contacts—Contact mechanism consists of a set of contacts hermetically sealed in a glass
envelope and actuated by a magnet attached to the operator. This sealed construction keeps
contaminants out of the contact area, making the reed switch the ideal switch for low voltage, low current
circuits such as programmable controllers.
NOTE: Because reed switches are operated by a magnet, they should not be installed in areas where strong magnetic
fields may be present. The devices should always be checked for proper operation after installation.
Definition
Polarity Power sources
Opposite polarities should not be
connected to the contacts of one limit
switch unless the limit switch is
specifically designed for such service
(isolated contacts—no polarity). See
page 209.
Power from different sources should not
be connected to the contacts of one limit
switch unless the switch is specifically
designed for such service (isolated
contacts—no polarity).
Incorrect
Correct
AC
DC
IM
CR
Incorrect
209
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial
Technical Information
Overriding Cams
The cam trailing edge on overriding cams must also be considered for maximum switch life
(see figure 6). Lever arm snap back causes shock loads which reduce switch life. Also, with
reversing cams the trailing edge becomes a leading edge on the return stroke. The
overtravel of the limit switch should not be exceeded, but 5° minimum to 15° travel past the
trip point is recommended. Additional travel should only be used for set up and emergencies.
Cam design procedures for limit switches with other than lever arm actuators vary from
switch type to switch type and are discussed along with other limit switch application design
suggestions in additional literature “Proper Application of Limit Switches” (SM444).
Contacts
• Make sure the electrical load is within limit switch contact ratings.
• The single pole, double throw contacts of a snap switch used in a limit switch should not be
used on opposite polarities. When load M1 is connected between the contact and line L2,
and load M2 is connected between the other contact and line L1 (figure 7), a line-to-line short
(bold line) can occur through the arc, which may be drawn as the contacts operate. When
contacts are connected to the same polarity (figure 8), this line-to-line short cannot occur.
• The same result can occur if different power sources are connected to the single-pole,
double-throw contacts of a snap switch.
• With limit switches having reed contacts, some form of transient protection should be used.
This protects the small contacts from damaging surges and increases contact life.
Coolant
• When possible, avoid mounting limit switches where they will be constantly exposed to
coolant, chips, etc. Although designed for such applications, switches last longer when not
exposed to these contaminants.
• Make sure cover screws are tightened to ensure a good oiltight seal.
• When possible, avoid using fire-resistant coolants of the phosphate ester type. Equipment
exposed to these coolants requires special seals and gaskets. Viton® fluoroelastomer, resistant
to these types of coolants, is the standard shaft seal material on Type C lever arm types. If
required, all gaskets, as well as boots on plunger types, can be furnished in Viton material.
Recommendations for Conduit Installation
Limit switch leakage is often traced to the conduit system. Coolant or condensation in the
conduit line can enter the switch through the conduit entry. Oil tightness depends on the
condition of the conduit connection and seal. Recommendations for installing conduit to
position switches are as follows:
• To ensure an oiltight seal, use thread sealant and a conduit seal or a sealing bushing
around the conduit fitting. Otherwise, the fitting probably will leak.
• Limit switches should be installed with the conduit end down whenever possible.
• If condensation or moisture is present inside the conduit, a Square D® conduit seal can be
inserted into the conduit entry. The conduit fitting can then be connected in the normal
manner. Thread sealant and a sealing bushing must still be used.
• Often a junction box fills with coolant and/or condensation, which backs up into the position
limit through the conduit. A simple solution is to drill a hole in the bottom of the junction box to
allow the liquid to drain out.
• If conduit leakage is severe, pre-wired and potted position limit (Forms Y184• and Y185•)
should be used. The switches are pre-wired with either individual wires or multiconductor
STOWA cord, and the receptacle is sealed with a potting material.
• The Square D limit switch is available with a pre-wired male plug receptacle. The
connector provides an effective oiltight seal when used with the appropriate female
connector cord.
30˚
30˚
60˚
0.72 min.
18
0.75
19
531632
Make these angles approximately
the same 45° recommended
Figure 6
Recommended
overtravel
5° min. to 15°
use additional
overtravel available
for set up and
emergency only
Do not contact
the roller within
shaded areas
L1 L2
L1 L2
M1
M1
M2
M2
531633
Incorrect
Figure 7—Contacts connected to
opposite polarities.
Line to line short (bold line) can
occure through arc drawn when
contacts operate
Arc
L1 L2
L1 L2
M1
M2
M1
M2
531634
Correct
Figure 8—Contacts connected to
same polarity. Line to line short
cannot occur when contacts
operate
Arc
210
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial
Technical Information
Terminal Identification
European (IEC) contact terminals marking
Single pole Double pole Each terminal is marked with 2 digits: First digit indicates the pole (circuit). The
second digit indicates the type of contact:
_1–_2 is N.C., _3–_4 is N.O.
i.e.: 11–12, 21–22 are N.C. 13–14, 23–24 are N.O.
Example of European Terminal Markings:
For switch elements without isolated contacts:
11-12 Is the N.C. contact of pole No. 1, 13-14 Is the N.O. contact of pole No. 2
For switch elements with isolated contacts:
13-14 Is the N.O. contact of pole No. 1, 21-22 Is the N.C. contact of pole No. 2
1st pole 2nd pole
11-12 11-12 21-22
13-14 13-14 23-24
11-12 11-12 21-22
13-14 13-14 23-24
Example of US Terminal Markings
Single pole Double pole Each contact terminal is marked with one digit, i.e., 1-2, 3-4, 5-6,7-8.
Example of US Terminal Markings:
For most snap switch elements (isolated contacts not usually on US manufactured
switches):
1-2 is the N.C. contact of pole No. 1,
3-4 is the N.O. contact of pole No. 1
5-6 is the N.C. contact of pole No. 2,
7-8 is the N.O. contact of pole No. 2
1st pole 2nd pole
1-2 1-2 5-6
3-4 3-4 7-8
1-2 1-2 5-6
3-4 3-4 7-8
Make-before-break (overlapping) SPDT: the normally open contact closes before
the normally closed contact opens.
Break-before-make (offset) SPDT: the normally closed contact opens before the
normally open contact closes.
Simultaneous make and break SPDT: the normally closed contact opens at the
same time as the normally open contact closes.
A = Maximum travel of the operator in mm or degrees.
B = Tripping travel of the contact.
C = Resetting travel of contact.
D = B-C = Differential travel.
P = Point from which positive opening is assured.
NOTE: The arrows indicate direction of actuation clockwise (CW) and return for simplicity
reasons. For counterclockwise (CCW) only direction of actuation is reversed.
Wiring diagrams
Form A Form B Form C Form AA Form BB
SPST-NO SPST-NC SPDT DPST-NO DPST-NC
Form CC Form X Form Y Form Zb Form Z
DPDT SPST-NO-DB SPST-NC-DB SPDT isolated contacts DPDT-DB
Form XX Form YY Form ZZ
DPST-NO-DB DPST-NC-DB DPDT-DB
21-22
13-14
21-22
13-14
21-22
13-14
B
C
0D
21 - 22
13 - 14
21 - 22
13 - 14
A
P
Contact open
Contact closed
Tripping
Resetting
211
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial
Cam Design
Excessive impact from improperly designed actuating systems is without question the leading cause of
premature failure of the electromechanical limit switch. At slow speed, impact is rarely troublesome, but
as speed increases, impact applied to the switch becomes a critical problem. In today's higher speed
machines, therefore, it is important to give proper consideration to correctly designed actuating systems.
These recommendations are designed to assist you in obtaining greater life from your limit switches. The
black sector in the roller indicates the recommended design limits of the angle of pressure shown in the
illustrations as “P”. Three main design and installation considerations are:
•The pressure applied by the actuating mechanism to switch operating lever should approximate
direction of lever rotation with a variation not to exceed 30°.
•Since the angle of pressure changes drastically with rotation of the lever, the cam must be designed
for proper pressure angles at all positions of the lever travel.
•The switch operating levers should be positioned as nearly parallel with the leading edges of the
cams as possible.
Considering these three factors:
•The cam in Figure 1A is satisfactory for speeds up to 50 fpm (15.2 mpm)
•The cam in Figure 1B is suitable for speeds up to 200 fpm (60.9 mpm) (nonuniform acceleration of
switch lever)
•The cam in Figure 1C is satisfactory for speeds up to 400 fpm (121.9 mpm) (uniform or other
controlled acceleration)
Designing proper pressure angles
for overriding cams for electromechanical limit switches
Don't underestimate the importance of adjusting the cams and operating levers in electromechanical limit
switches to provide the proper pressure angles in every travel position. Without the means to control the
angle of pressure or the limit of override, the operating lever may spring back with damaging results.
Lever flyback usually causes double pulsing of the contacts, and places additional stresses on the
mechanical system of the limit switch. The excessive impacts absorbed from inadequately designed
actuating devices eventually leads to abnormal wear and premature failure of the limit switch.
By looking closely at the actuating angles of the cam surface, designers and engineers can obtain the
maximum operating life from electromechanical limit switches. The following recommendations help
provide a workable knowledge of proper lever and cam angles—and how they are applied to secure
optimum conditions:
•Actuating cam on machinery or slide should provide a trailing edge so that upon overriding the
operating lever will not snap back.
•During the approach phase, the pressure angle of the cam should not vary from the lever angle
more than 30°.
•On the override phase, the angle of the trailing edge of the cam to the lever should be no more
than 60°.
If these guidelines are followed, the switch operating levers will always be approximately parallel with the
leading edges of the actuating surfaces or cams.
Figure 2 shows leading edge of cam about to depress and actuate the electromechanical limit switch.
The black sector of the roller indicates the recommended design limits of the angle of pressure shown in
drawings as “P”.
Figure 3 shows operating lever roller following the trailing edge of the cam on the override cycle. Unless
a one-way lever is used, the cam will operate the switch on the return cycle.
Application information
45°
45°
P
P
30°
60°
531666
Position 1
Figure 1A cam design for
speeds up to 50 fpm
Cam
Position 2
Cam
P
531667
4 in. min.
(101.6 mm)
Figure 1B cam design for
speeds from 50 to 200 fpm
(15.2 to 60.9 mpm).
Cam
15°
to
30°
P
D
531668
Precise
trip point
Figure 1C cam design for
speeds from 200 to 400 fpm
(60.9 to 121.9 mpm).
3 in. min.
(76.2 mm)
Cam
15°
to
30°
P
30°
.
531669
Cam
30° max.
Figure 2
P
531670
Cam
60° max.
Figure 3
212
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007C Heavy Duty Industrial
Linear/Angular Lever Travel
The table below can assist the designer of machine tools and conveyors, the plant engineer, or the
maintenance personnel responsible for keeping this equipment in a satisfactory operating condition.
The design engineer will find the table useful in making trouble-free cam layouts. For example, if the
recommended operating travel for a switch is between 15° and 30°, use the table to figure cam rise and
travel. This aids in determining what type of cam to design, its dimensions, etc.
The plant engineer can use the table to determine where to position levers on replacement switches or
revamped circuitry to operate existing cams. The engineer can also use the table to position the lever in
proper relationship to the cam, and to find out whether switches and cams are installed properly to obtain
maximum switch life.
All dimensions in the table are for 1 in. (25.4 mm) levers. If you use longer levers, multiply the
figures by the increased lever length. For example, for a 2 in. (50.8 mm) lever, use the multiplier 2.
1. Refer to document SM444R1 for additional information regarding Cam speed and angles.
Application information (continued)
All limit switches have a recommended operating travel and for best performance should be
installed within these limits. (1)
A B C A B C
1° 0.0002 (0.005 mm) 0.017 (0.43 mm) 46° 0.305 (7.7 mm) 0.719 (18.2 mm)
2° 0.0006 (0.015 mm) 0.035 (0.89 mm) 47° 0.318 (8.1 mm) 0.731 (18.6 mm)
3° 0.0014 (0.035 mm) 0.052 (1.3 mm) 48° 0.331 (8.4 mm) 0.743 (18.9 mm)
4° 0.002 (0.05 mm) 0.070 (1.8 mm) 49° 0.344 (8.7 mm) 0.755 (19.2 mm)
5° 0.004 (0.101 mm) 0.087 (2.2 mm) 50° 0.357 (9.0 mm) 0.766 (19.4 mm)
6° 0.005 (0.127 mm) 0.105 (2.6 mm) 51° 0.371 (9.4 mm) 0.777 (19.7 mm)
7° 0.007 (0.178 mm) 0.122 (3.1 mm) 52° 0.384 (9.7 mm) 0.788 (20.0 mm)
8° 0.010 (0.254 mm) 0.139 (3.5 mm) 53° 0.398 (10.1 mm) 0.799 (20.3 mm)
9° 0.012 (0.304 mm) 0.156 (4.0 mm) 54° 0.412 (10.4 mm) 0.809 (20.5 mm)
10° 0.015 (0.381 mm) 0.174 (4.4 mm) 55° 0.426 (11.0 mm) 0.819 (20.8 mm)
11° 0.018 (0.457 mm) 0.191 (4.8 mm) 56° 0.441 (11.2 mm) 0.829 (21.0 mm)
12° 0.022 (0.559 mm) 0.208 (5.3 mm) 57° 0.455 (11.5 mm) 0.839 (21.3 mm)
13° 0.026 (0.660 mm) 0.225 (5.7 mm) 58° 0.485 (12.3 mm) 0.857 (21.7 mm)
14° 0.030 (0.762 mm) 0.242 (6.1 mm) 59° 0.485 (12.3 mm) 0.857 (21.7 mm)
15° 0.034 (0.863 mm) 0.259 (6.6 mm) 60° 0.500 (12.7 mm) 0.866 (22 mm)
16° 0.039 (0.990 mm) 0.276 (7.2 mm) 61° 0.515 (13.1 mm) 0.875 (22.2 mm)
17° 0.044 (1.12 mm) 0.292 (7.4 mm) 62° 0.531 (13.5 mm) 0.883 (22.4 mm)
18° 0.049 (1.24 mm) 0.309 (7.8 mm) 63° 0.546 (14.0 mm) 0.891 (22.6 mm)
19° 0.054 (1.37 mm) 0.326 (8.3 mm) 64° 0.562 (14.3 mm) 0.899 (22.8 mm)
20° 0.060 (1.52 mm) 0.342 (8.7 mm) 65° 0.577 (14.6 mm) 0.906 (23.0 mm)
21° 0.066 (1.67 mm) 0.358 (9.1 mm) 66° 0.593 15.0( mm) 0.914 (23.2 mm)
22° 0.073 (1.85 mm) 0.375 (9.5 mm) 67° 0.609 15.5( mm) 0.921 (23.4 mm)
23° 0.079 (2.00 mm) 0.391 (9.9 mm) 68° 0.625 (16.0 mm) 0.927 (23.5 mm)
24° 0.086 (2.2 mm) 0.407 (10.3 mm) 69° 0.642 (16.3 mm) 0.934 (23.7 mm)
25° 0.094 (2.38 mm) 0.423 (10.7 mm) 70° 0.658 (16.7 mm) 0.940 (23.9 mm)
26° 0.101 (2.56 mm) 0.438 (11.1 mm) 71° 0.674 (17.1 mm) 0.946 (24.0 mm)
27° 0.109 (2.77 mm) 0.454 (11.5 mm) 72° 0.691 (17.5 mm) 0.951 (24.1 mm)
28° 0.117 (2.9 mm) 0.469 (12 mm) 73° 0.708 (18.0 mm) 0.956 (24.3 mm)
29° 0.125 (3.17 mm) 0.485 (12.3 mm) 74° 0.724 (18.4 mm) 0.961 (24.4 mm)
30° 0.134 (3.40 mm) 0.500 (12.7 mm) 75° 0.741 (19.0 mm) 0.966 (24.5 mm)
31° 0.143 (3.6 mm) 0.515 (13.1 mm) 76° 0.758 (19.2 mm) 0.970 (24.6 mm)
32° 0.152 (3.9 mm) 0.530 (13.4 mm) 77° 0.775 (20.0 mm) 0.974 (24.7 mm)
33° 0.161 (4.1 mm) 0.545 (14.0 mm) 78° 0.792 (20.1 mm) 0.978 (24.8 mm)
34° 0.171 (4.3 mm) 0.559 (14.2 mm) 79° 0.809 (20.5 mm) 0.982 (24.9 mm)
35° 0.181 (4.6 mm) 0.574 (14.6 mm) 80° 0.826 (21.0 mm) 0.985 (25.0 mm)
36° 0.191 (4.8 mm) 0.588 (15 mm) 81° 0.844 (21.4 mm) 0.988 (25.1 mm)
37° 0.201 (5.1 mm) 0.602 (15.3 mm) 82° 0.861 (21.8 mm) 0.990 (25.1 mm)
38° 0.212 (5.4 mm) 0.616 (15.6 mm) 83° 0.878 (22.3 mm) 0.993 (25.2 mm)
39° 0.223 (5.7 mm) 0.629 (16.0 mm) 84° 0.895 (22.7 mm) 0.995 (25.3 mm)
40° 0.234 (6.0 mm) 0.643 (16.3 mm) 85° 0.913 (23.2 mm) 0.996 (25.3 mm)
41° 0.245 (6.2 mm) 0.656 (16.6 mm) 86° 0.930 (23.6 mm) 0.9976 (25.3 mm)
42° 0.257 (6.5 mm) 0.669 (17.0 mm) 87° 0.948 (24.0 mm) 0.9986 (25.4 mm)
43° 0.269 (6.8 mm) 0.682 (17.3 mm) 88° 0.965 (24.5 mm) 0.9994 (25.4 mm)
44° 0.281 (7.1 mm) 0.695 (17.6 mm) 89° 0.983 (25.0 mm) 0.9999 (25.4 mm)
45° 0.293 (7.4 mm) 0.707 (18 mm) 90° 1.000 (25.4 mm) 1.000 (25.4 mm)
C
A
R
531671
Per inch R
Cam travel
B cam rise
C = R sine A
B = R (1-cosine A)
Dual dimensions: in. (mm)
213
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007C Heavy Duty Industrial
Installation Considerations
Lever Actuators
For limit switches with lever actuators, the actuating force should be applied as nearly perpendicular to the lever as practical and perpendicular
to the shaft axis about which the lever rotates.
Lever Actuators
Correct Incorrect
Dwelling Requirements Overtravel limitations
Where relatively fast motions are involved, the cams
should be so designed that the limit switch will be held
operated long enough to operate relays, valves, etc.
Operating mechanisms for limit switches should be so designed that, under any
operating or emergency conditions, the limit switch is not operated beyond its
overtravel limit position. A limit switch should not be used as a mechanical stop.
Correct Incorrect
Correct
Incorrect
Correct
Incorrect
Correct
Dwell
Stop
Free position
Operated
position
End of
overtravel
Stop
214
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007T and FT Severe Duty Mill and Foundry Switches
Conforming to NEMA A600 and UL508
Application Information
Type T — Ideal for applications requiring extra heavy duty contact ratings, or higher operating and reset
forces. Rugged mechanical construction with several different operating sequences in one basic switch.
Type FT — Designed specifically for rough foundry application. The shaft is entirely beyond the switch
case to prevent jamming of the lever arm due to build up of sand. A dust boot is furnished as standard to
further prevent sand packing and allow free movement of the lever arm. An extra long shaft bearing
makes the switch extremely rugged and able to handle the rough applications encountered in foundries,
mills, machine tool and similar industries. The switch will withstand hot falling sand up to 300° F (149° C).
Type T and FT
Enclosure — Oil-tight, dust-tight, water-tight, drip-tight meets NEMA Types 2, 4, and 13 requirements.
Die cast zinc construction.
Operating Sequences — Fifteen sequences available. Universal type has 12 different operating
sequences with CW only, CCW only, and neutral position operation. Standard type has three operating
sequences with CW and CCW operation. Various sequences will give quick make and break,
spring return with maintained contact, or slow make and break. Most sequences are convertible by
removing the base plate and adjusting the positioning plate and/or latches
Ambient Temperature Range — 10° F (-12.2° C) to 185° F (85° C) ambient at full rated load, up to 220°
F (104° C) ambient with single coil load.
Lever Arm — Die cast zinc construction with hardened, oil-impregnated, sintered iron rollers.
Conduit — 0.5 in. standard / 20 mm optional—Form M11
Mounting — Four baseplates provide end or side mounting holes and/or manifold mounting. All
mounting holes are 0.25 in. (6.35 mm) diameter. Two tapped holes on each side of switch allows side
mounting.
Contacts — SPDT1 double break and three point double throw single break. Silver contact tips. Phenolic
contact block. Nylon liner. Polarity must be the same on double throw contacts.
1. Single pole, double throw.
Description 9007 (convertible sequence)
9007T Mill Switches
Use the 9007T Mill switches instead of other limit switches in
the following applications:
• Where the current load exceeds the typical heavy duty limit
switch contact rating of 10 A and falls within the range of
up to 20 A continuous.
• Where an operating sequence is required that is not
possible on other limit switches. Fifteen sequences are
available. Universal type has twelve different operating
sequences with CW only, CCW only and neutral position.
Standard type has three operating sequences with CW and
CCW operation.
• Where higher reset forces are required due to foreign
material interfering with lever arm operation, or where long
heavy arms must reset against gravity.
9007FT Foundry Switches
The 9007FT Foundry switches are for use in foundries or mills
where the applications described above are required, and
where falling foundry sand or similar material could build up
and jam the operating mechanism. The shaft has a dust boot
and extends from the switch case, preventing sand build up
around the shaft. The devices can withstand hot falling sand
up to 300° F (149° C.).
9007T Mill Switches 9007FT Foundry Switches
Page 216 Page 218
Interpretation of Catalog Numbers:
page 239
215
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007T and FT Severe Duty Mill and Foundry Switches
Conforming to NEMA A600 and UL508
Environmental characteristics
Conforming to standards UL508
Product certifications UL Listed, CSA Certified, CE Marked
Protective treatment Corrosion resistant gray paint
Ambient air temperature -10 to +185 °F (-23 to +85 °C)
Housing can withstand falling sand at +300 °F (+149 °C)
Vibration resistance 10G (10–55 Hz)
Shock resistance 30G
Electric shock protection Class O
Degree of protection NEMA Types 1, 2, 4, 12, 13, IP65, 66, 67
Cable entry or connector 1/2" NPT (metric available)
Materials Cast zinc n
Contact block characteristics
Rated operational
characteristics hard contacts AC Voltage NEMA A600 Ithe = 20 A
20 A Resistive and continuous
Rated operational
characteristics hard contacts DC Voltage NEMA P 600 Ithe = 20 A
20 A Resistive and continuous
Rated insulation voltage 600 V
Rated impulse withstand voltage 2,500 Vac for 1 minute for CE, 2,200 Vac for 1 minute for UL, and
2,640 Vac for 1 minute for CSA
Positive opening No
Short circuit protection 20 A Bussmann Class CC KTK-R-20 fuse, non-time-delay
Terminal wire sizes (Cabling/Screw Clamp) 12 – 22 AWG (3.31 mm2 – 0.326 mm2) wire max.
Maximum actuation speed 15.2 mpm / 27.4 mpm (50 fpm / 90 fpm) with 45 ° Cam angle, levers only
Maximum current ratings for control circuit contacts
Contacts
AC DC
Volt s
Inductive
35% Power Factor
Resistive
75% Power Factor
Volt s
Inductive
and Resistive
Make Break Continuous
Carrying
Amperes
Make, Break and
Continuous Carrying
Amperes
Make and Break
Amperes Continuous
Carrying
Amperes
Amperes VA Amperes VA Single
Throw
Double
Throw
SPDT
Quick Make
and Break
120
240
480
600
150
75
37.5
30
18,000
18,000
18,000
18,000
20
12.5
6.25
5
2400
3000
3000
3000
20
20
20
20
20
20
20
20
120
250
600
5.0
1.0
0.2
º
º
º
20
20
20
All Slow Make
and Break
120
240
480
600
60
30
15
12
7200
7200
7200
7200
6
3
1.5
1.2
720
720
720
720
20
20
20
20
10
10
10
10
20
20
20
20
º
º
º
º
º
º
º
º
º
º
º
º
º
º
º
º
Characteristics for material and ratings comparisons — standard switches n
9007 Type T/FT Type L (R. B. Denison Lox Switch)
Body material Cast zinc Cast aluminum
Cover material Cast zinc Aluminum
Base plate material Steel with zinc plating Steel with chromate plating
Shaft seal material Nitrile PVC
Contact block material Phenolic Glass filled nylon
Moveable contact material Fine silver on copper backing Coin Silver on steel backing
Stationary contact material Fine silver on copper backing 90/10 AgCdO on copper backing
Low ambient temperature rating -10° F 0° F
High ambient temperature at full rating f180° F 200° F
Enclosure rating NEMA Types 1, 2, 4, 12 and 13 NEMA Types 1, 4 and 13
Vibration resistance 10G (10–150 Hz) 40G max (10-150 Hz)
f Many switches are available with higher or lower temperature limits by selecting special versions or special options. See page 237.
216
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007T Severe Duty Mill Switches
Universal Operating Sequences
Universal Catalog Numbers
Base Plate
A
B
C
D
9007TUA1
9007TUB1
9007TUC1
9007TUD1
9007TUA2
9007TUB2
9007TUC2
9007TUD2
9007TUA3
9007TUB3
9007TUC3
9007TUD3
9007TUA4
9007TUB4
9007TUC4
9007TUD4
9007TUA5
9007TUB5
9007TUC5
9007TUD5
9007TUA6
9007TUB6
9007TUC6
9007TUD6
No. 1 No. 2 No. 3 ➃No. 4 No. 5 No. 6
SPDT
Spring Return
CW Only
SPDT
Spring Return
CW Only
SPDT
Maintained
Contact
SPDT
Spring Return
Neutral Position
SPDT
Spring Return
CCW Only
SPDT
Spring Return
CCW Only
Characteristics
Nominal Operating Data
Pre-travel ➀14° Int. Pos. 9°, Final 16° 7° 6° 14° Int. Pos. 9°, Final 16°
Total travel 88° 88° 81° 81° 88° 88°
Differential 12° 5° 7° 5° 12° 5°
Operating torque 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m)
Repeat accuracy ➁± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm)
To convert sequences, remove base plate, position plate and latches. Reassemble positioning plate and latches as shown.
Weight lb (kg) 2.35 lb. (1.07 kg) 2.35 lb. (1.07 kg) 2.35 lb. (1.07 kg) 2.35 lb. (1.07 kg) 2.35 lb. (1.07 kg) 2.35 lb. (1.07 kg)
Universal Catalog Numbers (continued)
Base Plate
A
B
C
D
9007TUA7
9007TUB7
9007TUC7
9007TUD7
9007TUA8
9007TUB8
9007TUC8
9007TUD8
9007TUA9
9007TUB9
9007TUC9
9007TUD9
9007TUA10
9007TUB10
9007TUC10
9007TUD10
9007TUA11
9007TUB11
9007TUC11
9007TUD11
9007TUA12
9007TUB12
9007TUC12
9007TUD12
No. 7 No. 8 ➃No. 9 No. 10 No. 11 No. 12
SPDT
Maintained
SPDT
Maintained
Neutral Position
SPDT
Spring Return
Slow Make, Slow Break
SPDT
Spring Return
Slow Make. Slow Break
SPDT
Spring Return
Slow Mak, Slow Break
SPDT
Maintained
Characteristics
Nominal Operating Data
Pre-travel ➀10° 6° 12° 3° 12° 45°
Total travel 85° 81° 87° 81° 87° 90°
Differential 12° 10° 0° 0° 0° 0°
Operating torque 2.5 lb-in (0.28 N•m) 2.5 lb-in (0.28 N•m) 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m) 8 lb-in (0.9 N•m)
Repeat accuracy ➁± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm)
To convert sequences, remove base plate, position plate and latches. Reassemble positioning plate and latches as shown.
➂
Not adjustable
Weight lb (kg) 2.35 lb (1.07 kg) 2.35 lb. (1.07 kg) 2.35 lb. (1.07 kg) 2.35 lb. (1.07 kg) 2.35 lb. (1.07 kg) 2.35 lb. (1.07 kg)
Footnotes: see page 217
Surface
Mounted
AB
AB
Initial position
and CCW
CW
AB
ABAB
Initial position
and CCW
Middle
CW
Final
CW
AA
BB
Spring return of arm
to initial pos.
Contact pos.
maintained until
operated in reverse
CCW CW
If high speed cam
or snap-back is
present, use No. 12
AA
A
BB
B
Initial position
CWCCW
A
A
B
B
Initial position
and CW
CCW
AA
A
BB
B
Initial position
and CW
Middle
CCW
Final
CCW
A
A
BB
Surface
Mounted
A
A
B
B
If high speed cam
or snap-back
present, use No. 12
CCW
AA
A
BB
B
Initial position
If high speed cam
or snap-back is
present, use No. 12
CCW CW
A
A
B
B
Initial position
and CCW
CW
AA
A
BB
B
Initial position
CCW CW
A
A
B
B
Initial position
and CW
CCW
A
A
B
B
CCW
CW
➂ AB
Dimensions:
pages 222 to 225
Interpretation of Catalog Numbers:
page 239
Base Plates:
pages 221 and 222
217
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007T Severe Duty Mill Switches
Standard Operating Sequences
Standard Catalog Numbers
Base Plate
A
B
C
D
9007TSA1
9007TSB1
9007TSC1
9007TSD1
9007TSA2
9007TSB2
9007TSC2
9007TSD2
9007TSA3
9007TSB3
9007TSC3
9007TSD3
No. 1 No. 2 No. 3
SPDT
Spring Return
CW & CCW
SPDT
Spring Return
CW & CCW
SPDT
Spring Return
CW & CCW
Slow Make, Slow Break
Characteristics (nominal operating data)
Switch actuation By 30° cam
Type of actuation
Pre-travel ➀14° Int. Pos. 9°, Final 16° 9°
Total travel 89° 89° 89°
Differential 12° Int. Pos. 5.5°, Final 7.5° 5°
Reverse overtravel N/A (future availability) N/A (future availability) N/A (future availability)
Operating torque/force
1 pole & 2 pole 10 lb-in (1.13 N•m) 10 lb-in (1.13 N•m) 10 lb-in (1.13 N•m)
Terminal wire sizes
(Cabling/Screw Clamp)
#12–22 AWG
(3.31–0.326 mm2)
#12–22 AWG
(3.31–0.326 mm2)
#12–22 AWG
(3.31–0.326 mm2)
Repeatability ➁
(linear travel of cam) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm)
Cable entry
(metric available) 1/2" NPT 1/2" NPT 1/2" NPT
Weight lb (kg) 2.35 lb. (1.07 kg) 2.35 lb. (1.07 kg) 2.35 lb. (1.07 kg)
➀The pre-travel listed may vary up to 5° additional for universal switches or up to 2° additional for standard switches due to free travel of lever arm at initial position.
➁Linear travel of cam on 1.5 in. (38.1mm) lever arm.
➂Remove spring from the positioning plate.
➃Sequence 3, 7, and 8 devices are available but are not recommended where high speed cams or lever arm snap-back is present.
The application should be checked and No. 12 sequences substituted where possible.
Note: For Type FT foundry switches, change the “T” at the beginning of the equivalent Type number above to “FT” (Example: FTUB1). See page 218.
Surface
Mounted
A
A
B
B
Initial position
CW and CCW
AA
A
BB
B
Initial position
Middle Final
CW and CCW
A
A
B
B
Initial position
CW
and
CCW
218
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007FT Severe Duty Foundry Switches
Universal Operating Sequences
Universal Catalog Numbers
Base Plate
A
B
C
D
9007FTUA1
9007FTUB1
9007FTUC1
9007FTUD1
9007FTUA2
9007FTUB2
9007FTUC2
9007FTUD2
9007FTUA3
9007FTUB3
9007FTUC3
9007FTUD3
9007FTUA4
9007FTUB4
9007FTUC4
9007FTUD4
9007FTUA5
9007FTUB5
9007FTUC5
9007FTUD5
9007FTUA6
9007FTUB6
9007FTUC6
9007FTUD6
No. 1 No. 2 No. 3 ➃No. 4 No. 5 No. 6
SPDT
Spring Return
CW Only
SPDT
Spring Return
CW Only
SPDT
Maintained
Contact
SPDT
Spring Return
Neutral Position
SPDT
Spring Return
CCW Only
SPDT
Spring Return
CCW Only
Characteristics
Nominal Operating Data
Pre-travel ➀ 14° Int. Pos. 9°, Final 16° 7° 6° 14° Int. Pos. 9°, Final 16°
Total travel 88° 88° 81° 81° 88° 88°
Differential 12°5°7°5°12°5°
Operating torque 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m)
Repeat accuracy ➁± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm)
To convert sequences, remove base plate, position plate and latches. Reassemble positioning plate and latches as shown.
Weight lb (kg) 2.57 lb (1.17 kg) 2.57 lb (1.17 kg) 2.57 lb (1.17 kg) 2.57 lb (1.17 kg) 2.57 lb (1.17 kg) 2.57 lb (1.17 kg)
Universal Catalog Numbers (continued)
Base Plate
A
B
C
D
9007FTUA7
9007FTUB7
9007FTUC7
9007FTUD7
9007FTUA8
9007FTUB8
9007FTUC8
9007FTUD8
9007FTUA9
9007FTUB9
9007FTUC9
9007FTUD9
9007FTUA10
9007FTUB10
9007FTUC10
9007FTUD10
9007FTUA11
9007FTUB11
9007FTUC11
9007FTUD11
9007FTUA12
9007FTUB12
9007FTUC12
9007FTUD12
No. 7 No. 8 ➃No. 9 No. 10 No. 11 No. 12
SPDT
Maintained
SPDT
Maintained
Neutral Position
SPDT
Spring Return
Slow Make, Slow Break
SPDT
Spring Return
Slow Make, Slow Break
SPDT
Spring Return
Slow Make, Slow Break
SPDT
Maintained
Characteristics
Nominal Operating Data
Pre-travel ➀ 10° 6° 12° 3° 12° 45°
Total travel 85° 81° 87° 81° 87° 90°
Differential 12° 10° 0° 0° 0° 0°
Operating torque 2.5 lb-in (0.28 N•m) 2.5 lb-in (0.28 N•m) 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m) 12 lb-in (1.35 N•m) 8 lb-in (0.9 N•m)
Repeat accuracy ➁± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm)
To convert sequences, remove base plate, position plate and latches. Reassemble positioning plate and latches as shown.
➂➂
Not adjustable
Weight lb (kg) 2.57 lb (1.17 kg) 2.57 lb (1.17 kg) 2.57 lb (1.17 kg) 2.57 lb (1.17 kg) 2.57 lb (1.17 kg) 2.57 lb (1.17 kg)
Footnotes: see page 219
Surface
Mounted
AB
AB
Initial position
and CCW
CW
AB
ABAB
Initial position
and CCW
Middle
CW
Final
CW AA
BB
Spring return of
arm to initial pos.
Contact pos.
maintained until
operated in reverse
direction
CCW CW
If high speed cam
or snap-back is
present, use No. 12
AA
A
BB
B
Initial position
CWCCW
A
A
B
B
Initial position
and CW
CCW
AA
A
BB
B
Initial position
and CW
Middle
CCW
Final
CCW
A
A
BB
Surface
Mounted
A
A
B
B
If high speed cam
or snap-back
present, use No. 12
CCW
AA
A
BB
B
Initial position
If high speed cam or
snap-back present, use
No. 12
CCW CW
A
A
B
B
Initial position
and CCW
CW
AA
A
BB
B
Initial position
CCW CW
A
A
B
B
Initial position
and CW
CCW
A
A
B
B
CCW
CW
AB
Dimensions:
pages 222 to 225
Interpretation of Catalog Numbers:
page 239
219
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007FT Severe Duty Foundry Switches
Standard Operating Sequences
Standard Catalog Numbers
Base Plate
A
B
C
D
9007FTSA1
9007FTSB1
9007FTSC1
9007FTSD1
9007FTSA2
9007FTSB2
9007FTSC2
9007FTSD2
9007FTSA3
9007FTSB3
9007FTSC3
9007FTSD3
No. 1 No. 2 No. 3
Single Pole
Double Throw
Spring Return
CW & CCW
Single Pole
Double Throw
Spring Return
CW & CCW
Single Pole
Double Throw
Spring Return
CW & CCW
Slow Make
Slow Break
Characteristics (nominal operating data)
Switch actuation By 30° cam
Type of actuation
Pre-travel ➀ 14° Int. Pos. 9°, Final 16° 9°
Total travel 89° 89° 89°
Differential 12° Int. Pos. 5.5°, Final 7.5° 5°
Reverse overtravel N/A (future availability) N/A (future availability) N/A (future availability)
Operating torque/force
1 pole & 2 pole 10 lb-in (1.13 N•m) 10 lb-in (1.13 N•m) 10 lb-in (1.13 N•m)
Terminal wire sizes
(Cabling/Screw Clamp)
#12–22 AWG
(3.31–0.326 mm2)
#12–22 AWG
(3.31–0.326 mm2)
#12–22 AWG
(3.31–0.326 mm2)
Repeatability ➁
(linear travel of cam) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm) ± 0.004 in. (0.10 mm)
Cable entry
(metric available) 1/2" NPT 1/2" NPT 1/2" NPT
Weight lb (kg) 2.57 lb. (1.17 kg) 2.57 lb. (1.17 kg) 2.57 lb. (1.17 kg)
➀ The pre-travel listed may vary up to 5° additional for universal switches or up to 2° additional for standard switches due to free travel of lever arm at initial position.
➁ Linear travel of cam on 1.5 in. (38.1mm) lever arm.
➂ Remove spring from the positioning plate.
➃ Sequence 3, 7, and 8 devices are available but are not recommended where high speed cams or lever arm snap-back is present.
The application should be checked and No. 12 sequences substituted where possible.
Note: Type FT Foundry Switches are obtained by changing the “T” at the beginning of the equivalent type number to “FT” (Example: FTUB1).
Surface
Mounted
A
A
B
B
Initial position
CW and CCW
AA
A
BB
B
Initial position
Middle Final
CW and CCW
A
A
B
B
Initial position
CW
and
CCW
220
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007T and FT Severe Duty Mill and Foundry Switches
Lever Arms and Renewal Parts
Standard Roller
Arm Steel Roller Catalog
Number
Weight
lb (kg)
Length
in. (mm)
Diameter
in. (mm)
Roller
Position
Width
in. (mm)
1.5 (38.1) 0.75 (19) Optional 0.25 (6.3) 9007B1 0.17 (0.077)
1.5 (38.1) 1.0 (25.4) Optional 0.25 (6.3) 9007B2 0.19 (0.086)
1.5 (38.1) 1.38 (35) Optional 0.25 (6.3) 9007B3 0.23 (0.104)
2.5 (63.5) 0.75 (19) Optional 0.25 (6.3) 9007B7 0.25 (0.113)
2.5 (63.5) 1.0 (25.4) Optional 0.25 (6.3) 9007B8 0.25 (0.113)
2.5 (63.5) 1.38 (35) Optional 0.25 (6.3) 9007B9 0.27 (0.122)
1.5 (38.1) 0.75 (19) Optional 0.5 (12.7) 9007B12 0.34 (0.154)
1.5 (38.1) 1.0 (25.4) Optional 0.5 (12.7) 9007B13 0.34 (0.154)
1.5 (38.1) 1.38 (35) Optional 0.5 (12.7) 9007B14 0.42 (0.191)
5 (127) 0.75 (19) Optional 0.25 (6.3) 9007B19 1.00 (0.454)
2.88 (73.1) 0.75 (19) No roller — 9007B21 0.20 (0.091)
2.5 (63.5) 0.75 (19) Optional 0.5 (12.7) 9007B22 0.22 (0.100)
2.5 (63.5) 1.0 (25.4) Optional 0.5 (12.7) 9007B23 0.28 (0.127)
2.5 (63.5) 1.38 (35) Optional 0.5 (12.7) 9007B24 0.36 (0.163)
Adjustable (1) 0.75 (19) Optional 0.25 (6.3) 9007R18 0.50 (0.227)
Adjustable (1) 1.0 (25.4) Optional 0.25 (6.3) 9007R19 0.50 (0.227)
Adjustable (1) 1.38 (35) Optional 0.25 (6.3) 9007R20 0.50 (0.227)
1. Does not include lever arm clamp or rod. If lever arm clamp is required, use 9007R16 or R17.
Offset Type (for obtaining different cam track dimensions)
Arm Steel Roller Catalog
Number
Weight
lb (kg)
Length
in. (mm)
Diameter
in. (mm)
Roller
Position
Width
in. (mm)
1.5 (38.1) 0.75 (19) Inside offset 0.25 (6.3) 9007C1 0.50 (0.227)
1.5 (38.1) 1.0 (25.4) Inside offset 0.25 (6.3) 9007C2 0.50 (0.227)
1.5 (38.1) 1.38 (35) Inside offset 0.25 (6.3) 9007C3 0.50 (0.227)
1.5 (38.1) 0.75 (19) Outside offset 0.25 (6.3) 9007D1 0.18 (0.082)
1.5 (38.1) 1.0 (25.4) Outside offset 0.25 (6.3) 9007D2 0.18 (0.082)
1.5 (38.1) 1.38 (35) Outside offset 0.25 (6.3) 9007D3 0.18 (0.082)
1.88 (48) 0.75 (19) Outside offset 0.25 (6.3) 9007E4 0.20 (0.091)
1.88 (48) 1.0 (25.4) Outside offset 0.25 (6.3) 9007E5 0.27 (0.122)
1.88 (48) 1.38 (35) Outside offset 0.25 (6.3) 9007E6 0.27 (0.122)
1.88 (48) 0.75 (19) Inside offset 0.25 (6.3) 9007F4 0.30 (0.136)
1.88 (48) 1.0 (25.4) Inside offset 0.25 (6.3) 9007F5 0.30 (0.136)
1.88 (48) 1.38 (35) Inside offset 0.25 (6.3) 9007F6 0.30 (0.136)
120° Forked (for maintained contact lever arm type switches)
Arm Steel Roller Catalog
Number
Weight
lb (kg)
Length
in. (mm)
Diameter
in. (mm)
Roller
Position
Width
in. (mm)
1.5 (38.1) 0.75 (19) Same side 0.25 (6.3) 9007J1 0.31 (0.141)
1.5 (38.1) 1.0 (25.4) Same side 0.25 (6.3) 9007J2 0.40 (0.181)
1.5 (38.1) 0.75 (19) LH on opp. side 0.25 (6.3) 9007K1 0.50 (0.227)
1.5 (38.1) 1.0 (25.4) LH on opp. side 0.25 (6.3) 9007K2 0.50 (0.227)
1.5 (38.1) 0.75 (19) RH on opp. side 0.25 (6.3) 9007N1 0.66 (0.299)
1.5 (38.1) 1.0 (25.4) RH on opp. side 0.25 (6.3) 9007N2 0.70 (0.316)
90° Forked (for maintained contact lever arm type switches)
Arm Steel Roller Catalog
Number
Weight
lb (kg)
Length
in. (mm)
Diameter
in. (mm)
Roller
Position
Width
in. (mm)
1.5 (38.1) 0.75 (19) Same side 0.25 (6.3) 9007X1 0.30 (0.136)
1.5 (38.1) 1.0 (25.4) Same side 0.25 (6.3) 9007X2 0.40 (0.181)
1.5 (38.1) 0.75 (19) RH on opp. side 0.25 (6.3) 9007Y1 0.50 (0.227)
1.5 (38.1) 1.0 (25.4) RH on opp. side 0.25 (6.3) 9007Y2 0.50 (0.227)
1.5 (38.1) 0.75 (19) LH on opp. side 0.25 (6.3) 9007Z1 0.66 (0.299)
1.5 (38.1) 1.0 (25.4) LH on opp. side 0.25 (6.3) 9007Z2 0.70 (0.316)
Standard Roller
Offset Type
120° Forked
90° Forked
Dimensions:
pages 222 to 225
221
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007T and FT Severe Duty Mill and Foundry Switches
Lever Arms and Renewal Parts
Cable operated
Arm Steel roller Roller Catalog
Number
Weight
lb (kg)
Length
in. (mm)
Diameter
in. (mm) Roller Position Width
in. (mm)
1.5 (38.1) 0.75 (19) None None 9007Y3 —
2.5 in. (63.5mm) long with eyebolt 0.25 (6.3mm) I.D. instead of roller. 9007B27 —
Rod Type (used on conveyor systems or where unusual shapes are required)
Adjustable 0.75 (19) 0.19 (4.8) None 9007 R16 0.18 (0.081)
Adjustable 0.75 (19) 0.25 (6.3) None 9007R17 0.18 (0.081)
1. Rod not included
2. Key stock not included
Ball Bearing Type (for abrasive dust areas or with high speed cams)
1.5 (38.1) 0.75 (19) Center 0.28 (7.1) 9007B16 0.15 (0.068)
Weld-On Type (used where a special operator is required to weld to lever)
3.5 (89) 0.75 (19) None None 9007G10 0.50 (0.227)
One Way Roller Type (used with reversible cams for one way operations)
1.5 (38.1) 0.75 (19) Outside offset 0.25 (6.3) 9007D4 0.64 (0.290)
Conveyor Side Guide
8.44 in. (214.3) long with 1.5 in. (38.1) dia. 3.75 in. (95.2) Delrin® roller 9007R21 1.63 (0.739)
8.44 in. (214.3) long with 0.88 in. (22.3) dia. 3.75 in. (95.2) Delrin roller 9007R22 1.42 (0.644)
Separate Base Plates (2)
Style Mounting Holes Catalog
Number
Weight
lb (kg)
ANone (1) 2934D32G1
BEnd 2934D14G1 0.34 (0.154)
CSide 2934D33G1 0.42 (0.191)
DEnd 2934D34G1 0.36 (0.163)
1. No mounting holes in base plate. Side mounting holes in switch case must be used.
2. Acceptable wire sizes 14 – 18 AWG (2.08 – 0.823 mm2); recommended terminal clamp torque 13 – 16 lb-
in. (1.46 – 1.80 Nkm).
Optional Conduit Threads
Description Catalog
Number
Weight
lb (kg)
Metric
M20 - 20mm (per B.S. 4568) M11 —
Example: 9007TUB4M11
Three Point Contacts — Ordering Information
Select Type number of desired contact operating sequence for standard contact switch.
Change the letter following “T” or “FT” as shown below.
Change:
For example:
TUB1 changes to TYB1
TSB1 changes to TKB1
U to Y
S to K
Contact Configuration Changes
From:
With Reset Cable Operated
Rod Type
(rod not included)
Ball Bearing Type
Weld-On Type 1-Way Roller Type
Conveyor Side Guide
(use with 9007R16 or R17)
Base Plates
Style C Style DStyle BStyle A
222
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007T and FT Severe Duty Mill and Foundry Switches
Dimensions
Surface Mounting
Type T Type FT
Base Plates
Style A Style B Style C Style D
Dual dimensions:
Pipe Tap
Optional 20 Tap deep
Both Sides
0.56
14.2
0.75
19.05
2.06
52.32
2.63
66.80
2.44
61.98
0.50
12.7
0.75
19.05
0.56
14.22
0.25
6.35
0.38
9.53
0.63
15.9
0.91
23.1
3.0
76.2 0.75
19.05
0.56
14.22
0.56
14.22
2.63
66.80
3.41
86.61
0.63
16.00
0.91
23.11
Pipe Tap
Optional
0.50
12.7
0.75
19.05
20 Tap deep
Both Sides
0.25
6.35
0.38
9.53
2.06
52.3
0.75
19.0
0.56
14.2
2.63
66.8
0.56
14.2
0.91
23.1
0.63
16.0
2.44
62.0
Center of
Shaft
Mtg. Holes 0.257 Dia.
0.22
5.59
1.81
45.97
2.25
57.15
0.22
5.59
4.66
118.36
4.22
107.12
3.16
80.3
1
25.4
0.44
11.18
6.53
6.53
Mtg. Holes 0.257 Dia.
Center of
Shaft
4.50
114.3
2.81
71.37
1.81
35.81
2.44
61.98
129.29
1.13
28.70
0.66
16.76
3.25
82.55
0.38
9.65
1.25
31.75
3
76.2 Center of
Shaft
5.09
129.29
1.75
44.45
.22
5.59
.53
13.46
4.31
109.47
2.25
57.15 6.53
Mtg. Holes .257 Dia.
in.
mm
223
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007T and FT Severe Duty Mill and Foundry Switches
Dimensions
CAM Track Dimensions
Type T
Type FT
Dual dimensions:
R.
Type “D”
Roller
Arms
Type “C”
Roller
Arms
Type “B”
Roller
Arms
Type “D”
Roller
Arms
Type “B”
Roller
Arms
2.81
20.57
0.38
9.65
2.44
61.98
2.06
52.32
1.69
42.93
1.31
33.27
0.38
9.65
0.38
9.65
0.38
9.65
1.5
38.1
Type “E”
Roller
Arms
Type “F”
Roller
Arms
Type “E”
Roller
Arms
R.
0.75
19.05
3.28
83.31
2.53
65.26
1.59
40.39
0.94
23.88 0.75
19.05
0.84
21.34
0.84
21.34
1.875
47.62
Type “D”
Roller
Arms
Type “C”
Roller
Arms
Type “B”
Roller
Arms
Type “D”
Roller
Arms
Type “B”
Roller
Arms
R.
0.38
9.65
3.75
95.25
3.00
76.2
3.38
85.85
2.63
66.80
2.25
57.15
0.38
9.65
0.38
9.65
0.38
9.65
1.5
38.1
Type “E”
Roller
Arms
Type “E”
Roller
Arms
Type “F”
Roller Arms
R.
0.75
19.05
0.94
23.88 0.75
19.05
1.78
45.21
0.84
21.34
4.22
107.19
4.06
103.12
2.53
64.36
1.875
47.62
in.
mm
224
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
9007T and FT Severe Duty Mill and Foundry Switches
Dimensions
Type T and FT Lever Arms
Standard Roller Offset Type Adjustable Length Rod Type Ball Bearing Roller Type B16
Roller Arm for use with Type R17 1-Way Roller Type D4 Weld-On Arm Type G10 Cable Operated with Reset Type Y3
Cable Operated Type B27
Dual dimensions:
NOTE: All levers on this page can be used on Type C limit switches by installing the 9007S9 hub.
E
A
B
D
C
0.31
7.87
For dimension A refer to page 12.
B
A
E
Inside
Offset
CDF
F
CD
E
Outside
Offset
0.31
7.87
0.31
7.87
A
Hole for Rod
or Key Stock
0.31
7.87
1.66
43.16
0.69
17.53
1.75
44.45
0.75
19.05
0.88
22.35
1.50
38.1
0.28
7.11
0.70
17.78
B
0.44
11.18
0.38
9.53
0.88
22.35
0.28
7.11
0.75
19.05
1.75
44.45
1.50
38.10
1.50
38.10
0.25
6.35
0.38
9.65
0.38
9.65
0.31
7.87
0.75
19.05
0.625
15.88
1.50
38.10 3.50
88.9
0.09
2.29
0.63
16.0
0.31
7.84
1.50
38 0.25
6Dia.
90
o
2.12
54
1.06
27
2.28
58 0.38
10 Dia
2.50
64
0.63
16
0.50
13
Dia. Hole
0.34
8.64
3.53
89.66
1.13
28.7
0.31
7.87
1.06
26.92
2.50
63.5
0.47
11.89
0.59
15.06
0.31
7.87
0.75
19.05
0.75
19.05
2.41
61.21
in.
mm
225
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
9007T and FT Severe Duty Mill and Foundry Switches
Dimensions
Type T and FT Lever Arms (continued)
90° Forked 120° Forked
90
0
A
X1
X2 A
Y1
Y2
A
Z1
Z2 A
Arm Type Dim A
X1, Y1, Z1
X2, Y2, Z2
2.13
54.10
0.25
6.35
1.06
26.92
1.50
38.10
0.38
9.65 0.25
6.35
0.38
9.65
1.16
29.46
1.31
33.27
1.31
33.27
0.38
9.65 0.25
6.35
0.25
6.35
0.38
9.65
0.38
9.65
0.25
6.35
0.75
19.05
1.00
25.4
120° J1, K1, N1
J2, K2, N2
Type J1 & J2
Type N1 & N2
Type K1 & K2
2.59
65.79
0.75
19.05
1.50
98.10
0.38
9.53
0.75
19.05
1.00
25.4
0.25
6.35
0.38
9.53
0.38
9.53
0.38
9.53
1.16
29.46
0.50
12.7
0.38
9.53
0.25
6.35 0.67
17.02
1.34
34.04
1.34
34.04
0.25
6.35
0.38
9.53
0.67
17.02
226
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
L100, L300 Mill and Foundry Switches, L140, L2153 Cable Pulls, L529 Belt Conveyor
Conforming to NEMA A600 and UL508
Description L100, L300 Switches (fixed sequence)
L100W Switches f
Use the L100W Mill switches instead of other limit switches in the
following applications:
• Where the current load exceeds the typical heavy duty limit
switch contact rating of 10 A and falls within the range of up to
20 A continuous.
• Where an operating sequence is required that is not possible
on other limit switches (35 choices with the L switches).
• Where higher reset forces are required due to foreign material
interfering with lever arm operation, or where long heavy arms
must reset against gravity.
f L switches are not preceded by 9007. They are known as the
R.B. Denison® Lox Switch™ L, and include conveyor belt and
slack cable pull switches in the product offering.
L300W Switches
The L300W Foundry switches are for use in foundries or mills
where the applications described above are required, and where
falling foundry sand or similar material could build up and jam the
operating mechanism. The shaft has a dust boot and extends
from the switch case, preventing sand build up around the shaft.
The devices can withstand hot falling sand up to 300° F (149° C).
L100 Mill L300 Foundry
• Model L300 is an extra heavy duty
version for very aggressive environments
– The booted shaft design prevents
penetration of foreign materials such as
sand, dust, or grit between the shaft and
the bushing.
– Heavy duty stainless steel springs and
hardened spring operators permit longer
life under extreme lever fly-back and high
impact.
– Same parameters as L100 models,
except that the distance between the back
of the switch and the lever is increased by
0.34 in. (8.6 mm).
Page 228 Page 230
Features L100, L300, L140, L2153, L525 Cable Pulls (fixed sequence)
• Captive cover screws
• Heavy duty snap action mechanism prevents teasing or false
contact opening.
• Positive trip action prevents the lever from slipping around the
0.5 in. (12.7 mm) shaft even if not properly tightened.
• High current capability. 20 A maximum continuous
• Isolated (no polarity) double and triple circuits with double
break (throw) action
• Wide 0.25 in. (6.3 mm) contact gap ensures very high shock
and vibration resistance.
• Easy to access contacts allow for easy inspection and
replacement.
• Stamped contact configuration number for easy identification
even if the switch is painted
• Many contact arrangements to solve difficult applications
• Model L300 is an extra heavy duty version for very aggressive
environments.
– The booted shaft design prevents penetration of foreign
materials such as sand, dust, or grit between the shaft and the
bushing.
– Heavy duty stainless steel springs and hardened spring
operators permit longer life under extreme lever fly-back and
high impact.
– Same parameters as L100 models, except that the distance
between the back of the switch and the lever is increased by
0.34 in. (8.6 mm).
• Two and three circuits in CW, CCW, neutral position,
spring return and maintained, snap action or slow-make
slow-break, two steps (L525) are available.
• 2 circuit models can be CW or CCW field converted.
• Wide range of options: high shock and vibration, with gold
contact, low or very high temperature
• 0.5 in. (12.7 mm) NPT conduit entrance standard on 2-pole
models (5 wires max.)
• 0.75 in. (19 mm) NPT conduit entrance standard on 3-pole
models (7 wires max.)
L140 Mill and Foundry L2153 Mill and Foundry
Page 232 Page 232
Belt Conveyors
L525 Mill and Foundry
Conveyor belt limit switches are ideal for
policing the lateral movement of belt
conveyors. When the conveyor belt shifts, it
contacts the switch roller and a 12°
movement of the lever transfers the first set
of contacts. This set is usually wired to
initiate a warning alarm system to alert the
worker that the belt is moving off the rollers.
Further lateral movement of the belt, causing
the lever to move another 8°, trips the second
set of contacts. These contacts are normally
wired to the conveyor drive system and when
actuated stop the system, minimizing
damage to the conveyor or loss of material
on the belt.
Page 233
R. B. Denison
Type L
Limit Switch
NEMA A600
Made in U.S.A.
Lox-Switch
R. B. Denison
Type L
Limit Switch
NEMA A600
Made in U.S.A.
Lox-Switch
R. B. Denison
Type L
Limit Switch
NEMA A600 P600
Made in U.S.A.
Lox-Switch
R. B. Denison
Type L
Limit Switch
NEMA A600 P600
Made in U.S.A.
Lox-Switch
R. B. Denison
Type L
Limit Switch
NEMA A600 P600
Made in U.S.A.
Lox-Switch
227
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
L100, L300 Mill and Foundry Switches, L140, L2153 Cable Pulls, L529 Belt Conveyor
Environmental characteristics
Conforming to standards UL508
Product certifications UL Listed, CSA Certified, CE Marked
Protective treatment Corrosion resistant gray paint
Ambient air temperature -10 to +185 °F (-23 to +85 °C)
With H prefix: -10 to +350 °F (-23 to +177 °C). (1)
Vibration resistance 10G (10–55 Hz)
Shock resistance 30G
Electric shock protection Class O
Degree of protection NEMA Types 1, 2, 4, 12, 13, IP65, 66, 67
Cable entry or connector 1/2" NPT (metric available)
Materials Cast zinc n
1. For a switch with an ambient temperature rating up to 350 °F (177 °C), add an H to the beginning of the catalog number.
For example, change catalog number L100WS2M2 to HL100WS2M2.
Contact block characteristics
Rated operational
characteristics hard contacts AC Voltage NEMA A600 Ithe = 20 A
20 A Resistive and continuous
Rated operational
characteristics hard contacts DC Voltage NEMA P600 Ithe = 20 A
20 A Resistive and continuous
Rated insulation voltage 600 V
Rated impulse withstand voltage 2,500 Vac for 1 minute for CE, 2,200 Vac for 1 minute for UL, and
2,640 Vac for 1 minute for CSA
Positive opening No
Short circuit protection 20 A Bussmann Class CC KTK-R-20 fuse, non-time-delay
Terminal wire sizes
(Cabling/Screw Clamp) 12 – 22 AWG (3.31 mm2 – 0.326 mm2) wire max.
Maximum actuation speed 15.2 mpm / 27.4 mpm (50 fpm / 90 fpm) with 45 ° Cam angle, levers only
Maximum current ratings for control circuit contacts
Contacts
AC DC
Vol ts
Inductive
35% Power Factor
Resistive
75% Power Factor
Volt s
Inductive
and Resistive
Make Break Con-
tinuous
Carrying
Amperes
Make, Break and
Continuous Carrying
Amperes
Make and Break
Amperes
Con-
tinuous
Carrying
Amperes
Amperes VA Amperes VA Single
Throw
Double
Throw
SPDT
Quick Make
and Break
120
240
480
600
150
75
37.5
30
18,000
18,000
18,000
18,000
20
12.5
6.25
5
2400
3000
3000
3000
20
20
20
20
20
20
20
20
120
250
600
5.0
1.0
0.2
º
º
º
20
20
20
All Slow Make
and Break
120
240
480
600
60
30
15
12
7200
7200
7200
7200
6
3
1.5
1.2
720
720
720
720
20
20
20
20
10
10
10
10
20
20
20
20
º
º
º
º
º
º
º
º
º
º
º
º
º
º
º
º
Characteristics for material and ratings comparisons — standard switches n
9007 Type T/FT Type L (R. B. Denison Lox Switch)
Body material Cast zinc Cast aluminum
Cover material Cast zinc Aluminum
Base plate material Steel with zinc plating Steel with chromate plating
Shaft seal material Nitrile PVC
Contact block material Phenolic Glass filled nylon
Moveable contact material Fine silver on copper backing Coin Silver on steel backing
Stationary contact material Fine silver on copper backing 90/10 AgCdO on copper backing
Low ambient temperature rating -10° F 0° F
High ambient temperature at full rating f180° F 200° F
Enclosure rating NEMA Types 1, 2, 4, 12 and 13 NEMA Types 1, 4 and 13
Vibration resistance 10G (10–150 Hz) 40G max (10-150 Hz)
f Many switches are available with higher or lower temperature limits by selecting special versions or special options. See page 237.
228
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
L100 Mill Switches
Dimensions:
page 238
Operating Data:
page 229
Interpretaton of Catalog Numbers:
page 239
L100 Mill Switches
Description Operating Torque Contact Diagram Catalog Number Operating Data Weight, lb (kg)
Snap-action
CW
spring return
190 oz-in (1.34 N•m) L100WS2M1 A
(see page 229) 1.51 (0.68)
Snap-action
CCW
spring return
190 oz-in (1.34 N•m) L100WS2M2 A
(see page 229) 1.51 (0.68)
Maintained contact c
CW and CCW
snap action
45 oz-in (0.32 N•m) L100WS2M3 A
(see page 229) 1.51 (0.68)
Snap action
CW
spring return
190 oz-in (1.34 N•m) L100WDR2M4 A
(see page 229) 1.51 (0.68)
Snap action
CCW
spring return
190 oz-in (1.34 N•m) L100WDR2M5 A
(see page 229) 1.51 (0.68)
Maintained contact c
CW and CCW
snap action
45 oz-in (0.32 N•m) L100WDR2M6 A
(see page 229) 1.51 (0.68)
Snap action
CCW
spring return
190 oz-in (1.34 N•m) L100WDL2M7 A
(see page 229) 1.51 (0.68)
Snap action
CW
spring return
190 oz-in (1.34 N•m) L100WDL2M8 A
(see page 229) 1.51 (0.68)
Snap action
CW
1 N.C./ 2 N.O.
spring return
190 oz-in (1.34 N•m) L100WTR2M10 A
(see page 229) 1.51 (0.68)
Snap action
CCW
1 N.O./ 2 N.C.
spring return
190 oz-in (1.34 N•m) L100WTR2M11 A
(see page 229) 1.51 (0.68)
Maintained contact c
CW and CCW
snap action
3 poles
45 oz-in (0.32 N•m) L100WTR2M12 A
(see page 229) 1.51 (0.68)
Snap action
CCW
2 N.O./ 1 N.C.
spring return
190 oz-in (1.34 N•m) L100WTL2M13 A
(see page 229) 1.51 (0.68)
Snap action
CW
1 N.O./ 2 N.C.
spring return
190 oz-in (1.34 N•m) L100WTL2M14 A
(see page 229) 1.51 (0.68)
Maintained contact c
CW and CCW
snap action
3 poles
45 oz-in (0.32 N•m) L100WTL2M15 A
(see page 229) 1.51 (0.68)
Neutral position c
spring return
slow make and break
1 N.O. contact per direction
95 oz-in (0.67 N•m) L100WN2M16 B
(see page 229) 1.51 (0.68)
Neutral position c
spring return
slow make and break
1 N.O. contact for both directions
95 oz-in (0.67 N•m) L100WN2M17 B
(see page 229) 1.51 (0.68)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
5
6
3
4
5
6
3
4
5
6
3
4
5
6
3
4
5
6
3
4
5
6
3
4
1
2
5
6
1
2
5
6
1
2
5
6
1
2
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
229
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
L100 Mill Switches
L100 Mill Switches (continued)
Description Operating Torque Contact Diagram Catalog Number Operating Data Weight, lb (kg)
Neutral position c
spring return
slow make and break
1 N.C.-CW, 1 N.C.-CCW
95 oz-in (0.67 N•m) L100WNC2M18 B
(see table below) 1.51 (0.68)
Neutral position c
spring return
slow make and break
2 N.O.-CW, 1 N.O.-CCW
95 oz-in (0.67 N•m) L100WTRN2M20 B
(see table below) 1.51 (0.68)
Neutral position c
spring return
slow make and break
N.O.-CW, 2 N.O.-CCW
95 oz-in (0.67 N•m) L100WTLN2M21 B
(see table below) 1.51 (0.68)
Slow make-before-break
CW
spring return
170 oz-in (1.2 N•m) L100WS02M22 C
(see table below) 1.51 (0.68)
Slow make-before-break
CCW
spring return
170 oz-in (1.2 N•m) L100WS02M23 C
(see table below) 1.51 (0.68)
Neutral position c
N.O.-CW, N.O.-CCW
spring return
snap action
170 oz-in (1.2 N•m) L100WNS2M26 D
(see table below) 1.51 (0.68)
Neutral position c
N.O.-CW, N.O.-CCW
maintained in CCW only
170 oz-in (1.2 N•m) L100WNSR2M28 D
(see table below) 1.51 (0.68)
Neutral position c
N.O.-CW, N.O.-CCW
maintained in CW only
170 oz-in (1.2 N•m) L100WNSL2M29 D
(see table below) 1.51 (0.68)
Neutral position c
N.C.-CW, N.C.-CCW
spring return
snap action
170 oz-in (1.2 N•m) L100WNCS2M34 D
(see table below) 1.51 (0.68)
Neutral position c
N.O.-CW, N.O./N.C.-CCW
spring return
slow make and break
95 oz-in (0.67 N•m) L100WTRN1C2M38 B
(see table below) 1.51 (0.68)
Neutral position c
N.O./N.C.-CW, N.O.-CCW
spring return
slow make and break
95 oz-in (0.67 N•m) L100WTLN1C2M39 B
(see table below) 1.51 (0.68)
Neutral position c
N.O./N.C.-CW, N.C.-CCW
spring return
slow make and break
95 oz-in (0.67 N•m) L100WTRN2C2M40 B
(see table below) 1.51 (0.68)
Neutral position c
N.C.-CW, N.O./N.C.-CCW
spring return
slow make and break
95 oz-in (0.67 N•m) L100WTLN2M41 B
(see table below) 1.51 (0.68)
Neutral position c
N.O./N.C.-CW, N.C.-CCW
spring return
snap action
95 oz-in (0.67 N•m) L100WTRN2CS2M48 D
(see table below) 1.51 (0.68)
Operating Data for Contact Arrangements A B C D
Pretravel 17° nominal 7° maximum 7° nominal 9° nominal
Differential travel 11° nominal 4° maximum — 6° nominal
Overlapping travel ——4° nominal —
Total travel 80° 70° 80° 70°
Recommended installation travel 20°–35°10° − 25° 20° − 35° 13° − 30°
Repetitive accuracy of switch ± 0.03× — — ± 0.03×
Operating torque, max with return spring 190 oz-in (1.34 N•m) 95 oz-in (0.67 N•m) 170 oz-in (1.2 N•m) 170 oz-in (1.2 N•m)
Maintained contact 45 oz-in (0.317 N•m) — — 45 oz-in (0.317 N•m)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
Di
mens
i
ons:
page 238
O
perat
i
ng
S
equences
f
or
C
onveyor
B
e
l
ts:
page 233
230
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
L300 Foundry Switches
L300 Foundry Switches
Description Operating Torque Contact Diagram Catalog Number Operating Data Weight, lb (kg)
Snap-action
CW
spring return
190 oz-in (1.34 N•m) L300WS2M1 A
(see page 231) 1.54 (0.70)
Snap-action
CCW
spring return
190 oz-in (1.34 N•m) L300WS2M2 A
(see page 231) 1.54 (0.70)
Maintained contact c
CW and CCW
snap action
45 oz-in (0.32 N•m) L300WS2M3 A
(see page 231) 1.54 (0.70)
Snap action
CW
spring return
190 oz-in (1.34 N•m) L300WDR2M4 A
(see page 231) 1.54 (0.70)
Snap action
CCW
spring action
190 oz-in (1.34 N•m) L300WDR2M5 A
(see page 231) 1.54 (0.70)
Maintained contact c
CW and CCW
snap action
45 oz-in (0.32 N•m) L300WDR2M6 A
(see page 231) 1.54 (0.70)
Snap action
CCW
spring return
190 oz-in (1.34 N•m) L300WDL2M7 A
(see page 231) 1.54 (0.70)
Snap action
CW
spring return
190 oz-in (1.34 N•m) L300WDL2M8 A
(see page 231) 1.54 (0.70)
Snap action
CW
1 N.C./2 N.O.
spring return
190 oz-in (1.34 N•m) L300WTR2M10 A
(see page 231) 1.54 (0.70)
Snap action
CCW
1 N.O./ 2 N.C.
spring return
190 oz-in (1.34 N•m) L300WTR2M11 A
(see page 231) 1.54 (0.70)
Maintained contact c
CW and CCW
snap action
3 poles
45 oz-in (0.32 N•m) L300WTR2M12 A
(see page 231) 1.54 (0.70)
Snap action
CCW
2 N.O./ 1 N.C.
spring return
190 oz-in (1.34 N•m) L300WTL2M13 A
(see page 231) 1.54 (0.70)
Snap action
CW
1 N.O./ 2 N.C.
spring return
190 oz-in (1.34 N•m) L300WTL2M14 A
(see page 231) 1.54 (0.70)
Maintained contact c
CW and CCW
snap action
3 poles
45 oz-in (0.32 N•m) L300WTL2M15 A
(see page 231) 1.54 (0.70)
Neutral position c
spring return
slow make and break
1 N.O. contact per direction
95 oz-in (0.67 N•m) L300WN2M16 B
(see page 231) 1.54 (0.70)
Neutral position c
spring return
slow make and break
1 N.O. contact for both directions
95 oz-in (0.67 N•m) L300WN2M17 B
(see page 231) 1.54 (0.70)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
5
6
3
4
5
6
3
4
5
6
3
4
5
6
3
4
5
6
3
4
5
6
3
4
1
2
5
6
1
2
5
6
1
2
5
6
1
2
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Dimensions:
page 238
Operating Data:
page 231
Interpretaton of Catalog Numbers:
page 239
231
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
L300 Foundry Switches
L300 Foundry Switches (continued)
Description Operating Torque Contact Diagram Catalog Number Operating Data Weight, lb (kg)
Neutral position c
spring return
slow make and break
1 N.C.-CW, 1 N.C.-CCW
95 oz-in (0.67 N•m) L300WNC2M18 B
(see table below) 1.54 (0.70)
Neutral position c
spring return
slow make and break
2 N.O.-CW, 1 N.O.-CCW
95 oz-in (0.67 N•m) L300WTRN2M20 B
(see table below) 1.54 (0.70)
Neutral position c
spring return
slow make and break
N.O.-CW, 2 N.O.-CCW
95 oz-in (0.67 N•m) L300WTLN2M21 B
(see table below) 1.54 (0.70)
Slow make-before-break
CW
spring return
170 oz-in (1.2 N•m) L300WS02M22 C
(see table below) 1.54 (0.70)
Slow make-before-break
CCW
spring return
170 oz-in (1.2 N•m) L300WS02M23 C
(see table below) 1.54 (0.70)
Neutral position c
N.O.-CW, N.O.-CCW
spring return
snap action
170 oz-in (1.2 N•m) L300WNS2M26 D
(see table below) 1.54 (0.70)
Neutral position c
N.O.-CW, N.O.-CCW
maintained in CCW only
170 oz-in (1.2 N•m) L300WNSR2M28 D
(see table below) 1.54 (0.70)
Neutral position c
N.O.-CW, N.O.-CCW
maintained in CW only
170 oz-in (1.2 N•m) L300WNSL2M29 D
(see table below) 1.54 (0.70)
Neutral position c
N.C.-CW, N.C.-CCW
spring return
snap action
170 oz-in (1.2 N•m) L300WNCS2M34 D
(see table below) 1.54 (0.70)
Neutral position c
N.O.-CW, N.O./N.C.-CCW
spring return
slow make and break
95 oz-in (0.67 N•m) L300WTRN1C2M38 B
(see table below) 1.54 (0.70)
Neutral position c
N.O./N.C.-CW, N.O.-CCW
Spring return
slow make and break
95 oz-in (0.67 N•m) L300WTLN1C2M39 B
(see table below) 1.54 (0.70)
Neutral position c
N.O./N.C.-CW, N.C.-CCW
spring return
slow make and break
95 oz-in (0.67 N•m) L300WTRN2C2M40 B
(see table below) 1.54 (0.70)
Neutral position c
N.C.-CW, N.O./N.C.-CCW
spring return
slow make and break
95 oz-in (0.67 N•m) L300WTLN2M41 B
(see table below) 1.54 (0.70)
Neutral position c
N.O./N.C.-CW, N.C.-CCW
spring return
snap action
95 oz-in (0.67 N•m) L300WTRN2CS2M48 D
(see table below) 1.54 (0.70)
Operating Data for Contact Arrangements A B C D
Pretravel 17° nominal 7° maximum 7° nominal 9° nominal
Differential travel 11° nominal 4° maximum — 6° nominal
Overlapping travel — — 4° nominal —
Total travel 80° 70° 80° 70°
Recommended installation travel 20°–35°10° − 25° 20° − 35° 13° − 30°
Repetitive accuracy of switch ± 0.03× — — ± 0.03×
Operating torque, max with return spring 190 oz-in (1.34 N•m) 95 oz-in (0.67 N•m) 170 oz-in (1.2 N•m) 170 oz-in (1.2 N•m)
Maintained contact 45 oz-in (0.317 N•m) — — 45 oz-in (0.317 N•m)
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
Dimensions:
page 238
Operating Sequences for Conveyor Belts:
page 233
232
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
L140 and L2153 Cable Pulls
L140 Series Cable Pulls (1)
Circuit Direction Catalog
Number (2)
Weight
lb (kg)
1 N.C. CW right L142 1.54 (0.70)
1 N.O. and 1 N.C. CW right L143 1.54 (0.70)
1 N.O. and 1 N.C. CCW left L144 1.54 (0.70)
1 N.C. CCW left L145 1.54 (0.70)
2 N.O. and 1 N.C. CW right L146 1.54 (0.70)
2 N.C. and 1 N.O. CW right L147 1.54 (0.70)
2 N.O. and 1 N.C. CCW left L148 1.54 (0.70)
2 N.C. and 1 N.O. CCW left L149 1.54 (0.70)
1. Style K levers were designed specifically for this application; see page 235 (order separately).
2. To complete the catalog number, refer to page 239 and add the suffix for the mounting plate style and
the front cover material.
L2153 Dual Pull Stop
Description Catalog
Number
Weight
lb (kg)
Dual pull cord switch—maintained contacts
(stop and lever included) L2153 2.04 (0.93)
Characteristics
Pretravel 17° ± 2°
Differential travel 11° ± 2°
Overlapping travel —
To t a l t r a ve l 8 0 °
Recommended installation travel —
Repetitive accuracy of switch ± 0.03×
Operating torque, max with return spring 13–27 lb-in (1.47–3.05 N•m)
Reset torque 7–19 lb-in (0.79 –2.14 N•m)
Temperature range -20 to 120 °F (-6.6 to 48.8 °C)
Maintained contact —
L140 Cable Pull
L2153 Dual Pull Stop
233
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
L525 Belt Conveyor Switches
L525
Belt Conveyor Switches
Description Operating Torque Contact Diagram Catalog Number Weight
lb (kg)
2 step sequence
CW
spring return,
snap action,
2 N.O.
150 oz-in (1.06 N•m) L525WDR2M56 1.5 (0.68)
2 step sequence
CCW
spring return,
snap action,
2 N.O.
150 oz-in (1.06 N•m) L525WDL2M57 1.5 (0.68)
2 step sequence
CW
spring return,
snap action,
2 N.C.
150 oz-in (1.06 N•m) L525WDL2M58 1.5 (0.68)
2 Step sequence
CCW
spring return,
snap action,
2 N.C
150 oz-in (1.06 N•m) L525WDR2M59 1.5 (0.68)
2 Step sequence
CW
spring return,
snap action,
N.O./N.C c
150 oz-in (1.06 N•m) L100WS0S2M60 1.5 (0.68)
c Two step snap action. One normally closed, one normally open; CW operation to first step to 2-C. Further CW operation to second step, 1-O, 1-C. Spring return. Pretravel 9° nominal.
Additional travel 8° nominal. Differential second step 7° nominal. Differential first step 7° nominal.
Characteristics
Pretravel 12° nominal
Additional travel 8° nominal
Differential travel 7× nominal
Total travel 75° nominal
Operating torque, max with return spring 150 oz-in nominal (1.06 N•m)
5
6
3
4
5
6
3
4
5
6
3
4
1
2
5
6
1
2
5
6
1
2
5
6
1
2
5
6
1
2
5
6
1
2
5
6
5
6
3
4
5
6
3
4
5
6
3
4
1
2
3
4
1
2
3
4
1
2
3
4
Di
mens
i
ons:
page 238
234
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
L100/L300 Lever Arms
Lever Arms
Lever arms are constructed of machined aluminum.
Style A Steel Roller
Arm Steel roller Catalog
Number i
Weight
lb (kg)
Length Diameter Width
1.25 (31.7) 0.75 (19) 0.25 (6.3) AC 0.06 (0.027)
1.50 (38.1) 0.75 (19) 0.25 (6.3) AA 0.06 (0.027)
1.75 (44.4 0.75 (19) 0.25 (6.3) AD 0.07 (0.031)
2.00 (50.8) 0.75 (19) 0.25 (6.3) AH 0.08 (0.036)
2.25 (57.1) 0.75 (19) 0.25 (6.3) AJ 0.09 (0.041)
2.50 (63.5) 0.75 (19) 0.25 (6.3) AO 0.10 (0.045)
2.75 (69.8) 0.75 (19) 0.25 (6.3) AK 0.10 (0.045)
3.00 (76.2) 0.75 (19) 0.25 (6.3) AB 0.11 (0.050)
3.50 (88.9) 0.75 (19) 0.25 (6.3) AL 0.12 (0.054)
4.00 (101.6) 0.75 (19) 0.25 (6.3) AM 0.13 (0.059)
4.50 (114.3) 0.75 (19) 0.25 (6.3) AN 0.14 (0.064)
5.00 (127.0) 0.75 (19) 0.25 (6.3) AP 0.16 (0.073)
5.50 (139.7) 0.75 (19) 0.25 (6.3) AQ 0.18 (0.082)
6.00 (152.4) 0.75 (19) 0.25 (6.3) AR 0.20 (0.091)
i Example: AC — This is the complete catalog number to order.
Style A Options
Diameter Description Catalog Number—Add Suffix
1.00 (25.4) Roller 1
1.25 (32) Roller 4
1.50 38.1) Roller 2
—Nylon roller N
0.75 (19) Ball bearing roller R
—Stainless steel roller NS
Style B Steel Roller
Arm Steel roller Catalog
Number
Weight
lb (kg)
Length Diameter Width
1.50 (38.1) 0.75 (19) 0.50 (12.7) BA 0.06 (0.027)
2.00 (50.8) 0.75 (19) 0.50 (12.7) BH 0.08 (0.036)
2.50 (63.5) 0.75 (19) 0.50 (12.7) BO 0.10 (0.045)
3.00 (76.2) 0.75 (19) 0.50 (12.7) BB 0.12 (0.054)
4.00 (101.6) 0.75 (19) 0.50 (12.7) BM 0.13 (0.059)
4.50 (114.3) 0.75 (19) 0.50 (12.7) BN 0.14 (0.064)
5.50 (139.7) 0.75 (19) 0.50 (12.7) BQ 0.18 (0.082)
6.00 (152.4) 0.75 (19) 0.50 (12.7) BR 0.20 (0.091)
Style B Options
Diameter Description Catalog Number—Add Suffix
—Nylon roller N
1.50 (38.1) Roller 2
Style C Steel Roller On Side
Arm Steel roller Catalog
Number
Weight
lb (kg)
Length Diameter Width
1.25 (31.7) 0.75 (19) 0.25 (6.3) CC 0.06 (0.027)
1.50 (38.1 0.75 (19) 0.25 (6.3) CA 0.06 (0.027)
1.75 (44.4) 0.75 (19) 0.25 (6.3) CD 0.07 (0.031)
2.00 (50.8) 0.75 (19) 0.25 (6.3) CH 0.08 (0.036)
2.50 (63.5) 0.75 (19) 0.25 (6.3) CO 0.10 (0.045)
3.00 (76.2) 0.75 (19) 0.25 (6.3) CB 0.11 (0.050)
3.50 (88.9) 0.75 (19) 0.25 (6.3) CL 0.12 (0.054)
4.00 (101.6) 0.75 (19) 0.25 (6.3) CM 0.13 (0.059)
6.00 (152.4) 0.75 (19) 0.25 (6.3) CR 0.20 (0.091)
Style C Options
Diameter Description Catalog Number—Add Suffix
1.0 (24.5) Roller 1
1.25 (32) Roller 4
1.50 (38.1) Roller 2
— Nylon roller N
Style A
L
.75
19
.25
6.3 .25
6.3
.62
15
50
12
Dual dimensions: in. (mm)
Style B
L
.75
19 12
.62
15
.50
9.5
.37
.50
12
Style C
L
.75
19
.62
15.8 .25
6.3
.62
15.8
.50
12.7
Dimensions:
page 238
235
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
L100/L300 Lever Arms
Style E One Way Steel Roller
Arm Steel roller Catalog
Number
Weight
lb (kg)
Length Diameter Width
1.50 (38.1 0.75 (19) 0.50 (12.7) EA 0.30 (0.136)
1.75 (44.4) 0.75 (19) 0.50 (12.7) ED 0.40 (0.181)
3.00 (76.2) 0.75 (19) 0.50 (12.7) EB 0.50 (0.227)
Style E Options
Diameter
in. (mm) Description Catalog Number
Add Suffix
—Nylon roller N
Style F Offset Steel Roller
Arm Steel roller Roller Position Catalog
Number
Weight
lb (kg)
Length Diameter Offset Width
1.50 (38.1) 0.75 (19) 0.62 (15.8) 0.15 (3.8) FB 0.06 (0.027)
1.50 (38.1) 0.75 (19) 0.87 (22.2) 0.15 (3.8) FA 0.06 (0.027)
1.50 (38.1) 0.75 (19) 1.00 (25.4) 0.15 (3.8) FC 0.06 (0.027)
2.00 (50.8) 0.75 (19) 1.00 (25.4) 0.15 (3.8) FE 0.08 (0.036)
2.50 (63.5) 0.75 (19) 1.00 (25.4) 0.15 (3.8) FG 0.10 (0.045)
3.00 (76.2) 0.75 (19) 0.62 (15.8) 0.15 (3.8) FI 0.11 (0.050)
3.00 (76.2) 0.75 (19) 1.00 (25.4) 0.15 (3.8) FJ 0.11 (0.050)
Style F Options
Diameter Description Catalog Number—Add Suffix
1.00 (24.5) Roller 1
—Nylon roller N
Style K (for use with L140 cable pulls)
Arm Steel roller Description Catalog
Number i
Weight
lb (kg)
Length Diameter
1.50 (38.1 —— KA 0.05 (0.023)
2.50 (63.5) —— KO 0.08 (0.036)
3.00 (76.2) —— KB 0.09 (0.041)
i Example: KA — This is the complete catalog number to order.
Style L (renewal parts for L2153 dual pull stop)
Description Catalog
Number
Weight
lb (kg)
Lever AL1746 0.25 (0.113)
Mechanical stop AL1649 0.10 (0.045)
Style E
L
.75
19 50°
.50
12.7 .25
6.3
.68
17.4
.50
12.7
.62
15.8
Dual dimensions: in. (mm)
Style F
L
.62
15.8
.50
12.7
.75
19
.25
6.3
Style K
0.31
7.9
0.25
6.3 0.50
12.7 0.37
9.5
0.81
20.6
0.62
15.8
0.50
12.7
L
236
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
Lever Arms
Style R Steel Rod
Description Catalog
Number
Weight
lb (kg)
Hub only R0.10 (0.045)
Rod only R9 0.09 (0.041)
Style V Yoke (for maintained position switches)
Description Catalog
Number
Weight
lb (kg)
Yoke VA 0.50 (0.227)
Style V Options
Diameter Description Catalog Number—Add Suffix
1.0 (24.5) Roller 1
—Nylon roller N
0.75 (19) Ball bearing roller R
Style LA (to pass over switch cover)
Arm Catalog
Number
Weight
lb (kg)
Length
1.50 (30) LAA1 0.12 (0.054)
2.00 (50) LAH1 0.12 (0.054)
2.50 (63) LA01 0.12 (0.054)
Style LA Options
Diameter Description Catalog Number—Add Suffix
1.5 (38) Roller 2
—Nylon roller N
Style LC (to pass over switch cover)
Arm Catalog
Number
Weight
lb (kg)
Length
1.50 (30) LCA1 0.12 (0.054)
2.00 (50) LCH1 0.12 (0.054)
2.50 (63) LCO1 0.13 (0.059)
Style LC Options
Diameter Description Catalog Number—Add Suffix
1.25 (32) Roller 4
1.5 (38) Roller 2
—Nylon roller N
Rolling Pin (for use with 2 step switches for conveyor or belt applications)
Arm Catalog
Number
Weight
lb (kg)
Length
2.25 (75.1) AL1650 0.30 (0.136)
2.25 (75.1) High temp. Teflon® material AL16501 0.33 (0.150)
3.0 (50.8) AL1802 0.33 (0.150)
Rolling Pin (adjustable)
Arm Steel roller Catalog
Number
Weight
lb (kg)
Length Diameter Width
2.00 (51) to
4.00 (102) 0.75 (19) 0.25 (6.3) AL1650 0.30 (0.136)
i Example: KA — This is the complete catalog number to order.
Note: No hub component is needed for Type AL rolling pins. The arm mounts directly onto the shaft of the switch.
Style R
1.00
25.4
.87
22.2 .68
17.4
.18
4.7
9.00
228
Dual dimensions: in. (mm)
Style V
Adjustable from
75° to 180° in
increments of 7.5°
70°
180°
1.56
39.8
.50
12.7
.62
15.8
.75
19
3.12
79.3
Style LA
L
.75
19
1.25
31.7
1.00
25.4
1.00
25.4
Style LC
L
1.00
25.4
1.37
34.9
.75
19
1.25
31.7
Rolling Pin Adjustable Rolling Pin
1.25
31.8
2.23
56.64
5.73
145.54
3.00
76.2
.97
2.45
.75
19
4.06
103
1.93
23.8
Dimensions:
page 238
237
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
L100/L300 Options and Accessories
Housing Options k
Example Catalog Number Weight
Description Full Catalog Number Add Prefix lb (kg)
0.75 in. conduit opening
Available on 2 circuit switches.
Standard on 3 circuit switches
L100WS2M1 changes to
GL100WS2M1 G1.54 (0.70)
High temperature 0 to +350 °F
(-17.7 to +176.6 °C) c
Metal front cover only
L100WS2M1 changes to
HL100WS2M1 H1.54 (0.70)
Low temperature -20 to 200 °F
(-28.8 to +93.3 °C) c
L100WS2M1 changes to
TL100WS2M1 T1.54 (0.70)
High shock
Available only on operating
sequences 1, 2, 4, 5, 7-11, 13, 14
L100WS2M1 changes to
L526WS2M1 526
1.54 (0.70)
L300WS2M1 changes to
L326WS2M1 326
Gold contacts
L100WS2M1 changes to
L522WS2M1 522
1.54 (0.70)
L300WS2M1 changes to
L322WS2M1 322
Metric conduit threads
M20 (20 mm)
L100WS2M1 changes to
ML100WS2M1 M1.54 (0.70)
Wiring
Example Catalog Number Weight
lb (kg)
Description Full Catalog Number Add Prefix
Straight male receptacle 4-pin q
Factory prewired
L100WS2M1 changes to
PL100WS2M1 P1.54 (0.70)
90° Angle male receptacle 4-pin q
Factory prewired—facing right
L100WS2M1 changes to
APL100WS2M1 AP 1.54 (0.70)
Ministyle male receptacle j
8 A max. 5-pin (double circuit) or
7 A max. 7-pin (triple circuit)
L100WS2M1 changes to
BL100WS2M1 B1.54 (0.70)
Potted and prewired Example Add Suffix Weight
lb (kg)
Full Catalog Number
5 wires 6 feet (1.8 mm) long L100WS2M1 changes to
L100WS2M1PP
1.54 (0.70)
5 wires 12 feet (3.6 mm) long L100WS2M1 changes to
L100WS2M1P12 P12
5 wires 18 feet (5.5 mm) long L100WS2M1 changes to
L100WS2M1P18 P18
Front Covers
Example Catalog Number Weight
lb (kg)
Description Full Catalog Number Add Suffix
Standard metal M—
Transparent plastic cover with
metal frame PF —
Transparent plastic cover with
metal frame and
Neon indicator light (not connected)
GF —
L100WS2M1 changes to
L100WS2PF 1 1.54 (0.70)
Accessories
Description Catalog Number Weight
lb (kg)
Sealed female plug and cable for P and AP connector
4 pin, #16 AWG STO cable
140 °F (60 °C)
4 ft. (1.21 m) 1010004 1.20 (0.54)
6 ft. (1.82 m) 1010006 1.25 (0.57)
10 ft. (3.04 m) 10100010 1.50 (0.68)
Sealed female plug and cable for ministyle connector (B)
5 pin, #16 AWG STO cable
221 °F (105 °C)
3 ft. (0.91 m) BH2053 1.50 (0.68)
6 ft. (1.82 m) BH2056 1.70 (0.77)
12 ft. (3.65 m) BH20512 2.10 (0.95)
kOther options available — contact your local field office for details.
qReceptacle is a 4-pin male APL/PL-SWTS, Cannon part # MS3102E20-4P-F79 or equal.
jMinistyle male connectors are:
• 5-pin: Brad Harrison #41310 (or equal)
• 7-pin: Brad Harrison #42805 (or equal)
cThe minimum temperatures listed are based on the absence of freezing moisture or water.
Straight Male Connector
Mini Change Connector
90° Angle Male Connector
238
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Limit Switches
Limit Switches
R.B.Denison® Lox-Switch™ L Severe Duty Mill and Foundry Switches
Dimensions
Switches
Type L100 Type L300
Base Plates
Style 1 Style 2 Style 3 Style 4
Receptacles
PL APL 101000
Dual dimensions:
.28
7.1
3.93
100
4.95
125.7
1.81
46
2.31
58.7
Switch shown
with AA lever
.95
24.2
2.10
53.5
2.62
66.7 4.95
125.7
.89
22.6
.75
19
1.78
45.2
1.53
38.8
Type L with
style 2
mounting plate
.25” - 20 tap
.625” deep
2 holes
both sides
1/2” pipe tap - 2 circuit switches
3/4” pipe tap - 3 circuit switches
.28
7.1
4.22
107.2
3.93
100
1.81
46
2.31
58.7
.95
24.2
2.10
53.5
2.62
66.7 4.95
125.7
.89
22.6
.75
19
2.12
53.9 1.75
44.4
.25” - 20 tap
.625” deep
2 holes
both sides
1/2” pipe tap - 2 circuit switches
3/4” pipe tap - 3 circuit switches
CA Lever
1.87
47.5
AA Lever
2.81
71.4 2.25
57.1
1.40
35.7
.20
5.2 slot
3.25
82.5
.26
6.7
dia.
mounting hole
1.40
35.7
2.43
61.9
4.56
115.8
5.5
.21
16.5
6.5
38.1
1.50
1.81
46
.90
22.8
2.25
57.1 .26
6.7
4 mounting
holes
4.22
107.2
.26 dia.
6.7
1.40
35.7
.62
15.8
115.8
4.56
80.5
3.17
mtg.
hole
4.94
125.4
.75
19
3.17
80.5
.90
23
.62
15
dia.
hole
.26
6.7
4 mounting holes
.95
2.87
73
3.20
81.3
3.59
91.2
24.2
1.09
27.7
1.31
33.3 2.26
57.3
.95
24.2
1.48
37.7
1.46
37.3
.72
18.2
2.65
67.4
Ground clamp
screw
4 Ft.
16/4 STO cable
Yellow
in.
mm
239
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
Limit Switches
Interpretation of Catalog Numbers
Severe Duty Mill and Foundry Switches
Interpretation of Catalog Numbers
The interpretation of catalog numbers is intended to help you understand how the catalog number is laid out. It is to be used with existing
numbers only. The table below should not be used to generate new catalog numbers. If the contact sequence required is not listed, contact
your local field office.
L100 and L300
The only modifications to the existing catalog numbers are:
•Base Plates: Select style 1, 2, 3 or 4
•Front Covers: Select metal, transparent plastic, or transparent plastic with neon light.
For special features see page 237.
9007T and FT
240
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Sensors, Limit Switches, and Connector Cables
Index
Limit Switches
10100010 . . . . . . . . 237
1010004 . . . . . . . . . 237
1010006 . . . . . . . . . 237
2358C22G3 . . . . . . 189
2358C22G6 . . . . . . 189
2358C22G8 . . . . . . 189
2358C6G2 . . . . . . . 189
2358C6G3 . . . . . . . 189
2358C6G6 . . . . . . . 189
2358C6G8 . . . . . . . 189
2934D14G1 . . . . . . 221
2934D32G1 . . . . . . 221
2934D33G1 . . . . . . 221
2934D34G1 . . . . . . 221
31032-488-01 . . . . . 181
31032-815-01 . . . . . 181
7A1 . . . . . . . . . . . . . 157
7A1N . . . . . . . . . . . . 157
7A2 . . . . . . . . . . . . . 157
7A2N . . . . . . . . . . . . 157
7A3N . . . . . . . . . . . . 157
7A4N . . . . . . . . . . . . 157
7A7N . . . . . . . . . . . . 157
7B1N . . . . . . . . . . . . 157
7B2 . . . . . . . . . . . . . 157
7B2N . . . . . . . . . . . . 157
7B3N . . . . . . . . . . . . 157
7B4N . . . . . . . . . . . . 157
7B7N . . . . . . . . . . . . 157
7D . . . . . . . . . . . . . . 157
7DN . . . . . . . . . . . . . 157
7F1N . . . . . . . . . . . . 157
7F2N . . . . . . . . . . . . 157
7F3N . . . . . . . . . . . . 157
7F4N . . . . . . . . . . . . 157
7F7N . . . . . . . . . . . . 157
7J1N . . . . . . . . . . . . 157
7J2N . . . . . . . . . . . . 157
7J3N . . . . . . . . . . . . 157
7J4N . . . . . . . . . . . . 157
7J7N . . . . . . . . . . . . 157
7JX4N . . . . . . . . . . . 157
7N . . . . . . . . . . . . . . 157
7S . . . . . . . . . . . . . . 157
7XA1 . . . . . . . . . . . . 157
7XA1N . . . . . . . . . . 157
7XA2 . . . . . . . . . . . . 157
7XA2N . . . . . . . . . . 157
7XA3N . . . . . . . . . . 157
7XA4N . . . . . . . . . . 157
7XA7N . . . . . . . . . . 157
7XB1N . . . . . . . . . . 157
7XB2 . . . . . . . . . . . . 157
7XB2N . . . . . . . . . . 157
7XB3N . . . . . . . . . . 157
7XB4N . . . . . . . . . . 157
7XB7N . . . . . . . . . . 157
7XF1N . . . . . . . . . . . 157
7XF2N . . . . . . . . . . . 157
7XF3N . . . . . . . . . . . 157
7XF4N . . . . . . . . . . . 157
7XF7N . . . . . . . . . . . 157
7XJ1N . . . . . . . . . . . 157
7XJ2N . . . . . . . . . . . 157
7XJ3N . . . . . . . . . . . 157
7XJ7N . . . . . . . . . . . 157
9007A . . . . . . . . . . . 189
9007AA0S . . . . . . . . 192
9007AA1 . . . . . . . . . 190
9007AA11M . . . . . . . 195
9007AA17 . . . . . . . . 190
9007AA18M . . . . . . . 195
9007AA1M . . . . . . . . 195
9007AA1S . . . . . . . . 192
9007AA2 . . . . . . . . . 190
9007AA2S . . . . . . . . 192
9007AA5 . . . . . . . . . 191
9007AA5M . . . . . . . . 195
9007AA6 . . . . . . . . . 191
9007AA8 . . . . . . . . . 190
9007AA8M . . . . . . . . 195
9007AA9 . . . . . . . . . 191
9007AA9M . . . . . . . . 195
9007B . . . . . . . . . . . 189
9007B1 . . . . . . . . . . 220
9007B12 . . . . . . . . . 220
9007B13 . . . . . . . . . 220
9007B14 . . . . . . . . . 220
9007B16 . . . . . . . . . 221
9007B19 . . . . . . . . . 220
9007B2 . . . . . . . . . . 220
9007B21 . . . . . . . . . 220
9007B22 . . . . . . . . . 220
9007B23 . . . . . . . . . 220
9007B24 . . . . . . . . . 220
9007B27 . . . . . . . . . 221
9007B3 . . . . . . . . . . 220
9007B7 . . . . . . . . . . 220
9007B8 . . . . . . . . . . 220
9007B9 . . . . . . . . . . 220
9007BA0S . . . . . . . . 192
9007BA1 . . . . . . . . . 190
9007BA11 . . . . . . . . 190
9007BA11M . . . . . . . 195
9007BA12 . . . . . . . . 190
9007BA13 . . . . . . . . 190
9007BA15 . . . . . . . . 191
9007BA17 . . . . . . . . 190
9007BA18 . . . . . . . . 190
9007BA18M . . . . . . . 195
9007BA1M . . . . . . . . 195
9007BA1S . . . . . . . . 192
9007BA2 . . . . . . . . . 190
9007BA2S . . . . . . . . 192
9007BA3 . . . . . . . . . 193
9007BA3S . . . . . . . . 193
9007BA4 . . . . . . . . . 190
9007BA4S . . . . . . . . 192
9007BA5 . . . . . . . . . 191
9007BA5M . . . . . . . . 195
9007BA6 . . . . . . . . . 191
9007BA8 . . . . . . . . . 190
9007BA8M . . . . . . . . 195
9007BA9 . . . . . . . . . 191
9007BA9M . . . . . . . . 195
9007BT1 . . . . . . . . . 181
9007BT3 . . . . . . . . . 181
9007C . . . . . . . . . . . 189
9007C1 . . . . . . . . . . 220
9007C2 . . . . . . . . . . 220
9007C3 . . . . . . . . . . 220
9007C52•• . . . . . . . . . . 9
9007C54••• . . . . . . . . . 9
9007C54B2M11 . . . 177
9007C54B2P6 . . . . 176
9007C54B2Y1901 . 178
9007C54B2Y19019 178
9007C54B2Y1912 . 178
9007C54DM11 . . . . 177
9007C54DP6 . . . . . 176
9007C54DY1901 . . 178
9007C54DY19019 . 178
9007C54DY1912 . . 178
9007C54EM11 . . . . 177
9007C54EP6 . . . . . 176
9007C54EY1901 . . 178
9007C54EY19019 . 178
9007C54EY1912 . . 178
9007C54FM11 . . . . 177
9007C54FP6 . . . . . . 176
9007C54FY1901 . . . 178
9007C54FY19019 . . 178
9007C54JM11 . . . . 177
9007C54JP6 . . . . . . 176
9007C54JY1901 . . . 178
9007C54JY19019 . . 178
9007C54JY1912 . . . 178
9007C54LM11 . . . . 177
9007C54LP6 . . . . . . 176
9007C54LY1901 . . . 178
9007C54LY19019 . . 178
9007C54LY1912 . . . 178
9007C62••• . . . . . . . . . 9
9007C62B2M11 . . . 177
9007C62B2P6 . . . . 176
9007C62B2Y19016 178
9007C62DM11 . . . . 177
9007C62DP6 . . . . . 176
9007C62DY19016 . 178
9007C62EM11 . . . . 177
9007C62EP6 . . . . . 176
9007C62EY19016 . 178
9007C62FM11 . . . . 177
9007C62FP6 . . . . . . 176
9007C62FY19016 . . 178
9007C62FY1912 . . . 178
9007C62JM11 . . . . 177
9007C62JP6 . . . . . . 176
9007C62JY19016 . . 178
9007C62LM11 . . . . 177
9007C62LP6 . . . . . . 176
9007C62LY19016 . . 178
9007C66••• . . . . . . . . . 9
9007C68••• . . . . . . . . . 9
9007C84••• . . . . . . . . . 9
9007C86••• . . . . . . . . . 9
9007CA0S . . . . . . . 192
9007CA1 . . . . . . . . . 190
9007CA11 . . . . . . . 190
9007CA11M . . . . . . 195
9007CA12 . . . . . . . . 190
9007CA13 . . . . . . . . 190
9007CA15 . . . . . . . .191
9007CA17 . . . . . . . .190
9007CA18 . . . . . . . .190
9007CA18M . . . . . . .195
9007CA1M . . . . . . . .195
9007CA1S . . . . . . . . 192
9007CA2 . . . . . . . . .190
9007CA2S . . . . . . . . 192
9007CA3 . . . . . . . . .193
9007CA31 . . . . . . . .191
9007CA3S . . . . . . . . 193
9007CA4 . . . . . . . . .190
9007CA4S . . . . . . . . 192
9007CA5 . . . . . . . . .191
9007CA5M . . . . . . . .195
9007CA6 . . . . . . . . .191
9007CA8 . . . . . . . . .190
9007CA8M . . . . . . . .195
9007CA9 . . . . . . . . .191
9007CA9M . . . . . . . .195
9007CO52 . . . . . . . . 188
9007CO54 . . . . . . . 188
9007CO62 . . . . . . . 188
9007CO66 . . . . . . . . 188
9007CO68 . . . . . . . . 188
9007CR53•• . . . . . . . . .9
9007CR61•• . . . . . . . . .9
9007CR65•• . . . . . . . . .9
9007CR67•• . . . . . . . . .9
9007CT10 (1) . . . . . . 181
9007CT11 . . . . . . . . 181
9007CT12 . . . . . . . . 181
9007CT13 (2) . . . . . . 181
9007CT52 . . . . . . . . 188
9007CT54 . . . . . . . . 188
9007CT54 . . . . . . . . 188
9007CT62 . . . . . . . . 188
9007CT62 . . . . . . . . 188
9007CT62 . . . . . . . . 188
9007D . . . . . . . . . . . 189
9007D1 . . . . . . . . . . 220
9007D2 . . . . . . . . . . 220
9007D3 . . . . . . . . . . 220
9007D4 . . . . . . . . . . 221
9007DA0S . . . . . . . . 192
9007DA1 . . . . . . . . .190
9007DA11 . . . . . . . .190
9007DA11M . . . . . . .195
9007DA12 . . . . . . . .190
9007DA13 . . . . . . . .190
9007DA15 . . . . . . . .191
9007DA17 . . . . . . . .190
9007DA18 . . . . . . . .190
9007DA18M . . . . . . .195
9007DA1M . . . . . . . .195
9007DA1S . . . . . . . . 192
9007DA2 . . . . . . . . .190
9007DA2S . . . . . . . . 192
9007DA3 . . . . . . . . .193
9007DA31 . . . . . . . .191
9007DA3S . . . . . . . . 193
9007DA4 . . . . . . . . .190
9007DA4S . . . . . . . . 192
9007DA5 . . . . . . . . .191
Sensors, Limit Switches, and Connector Cables
Index
241
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
9007DA5M . . . . . . . .195
9007DA6 . . . . . . . . .191
9007DA8 . . . . . . . . .190
9007DA8M . . . . . . . .195
9007DA9 . . . . . . . . .191
9007DA9M . . . . . . . .195
9007E . . . . . . . . . . . .189
9007E4 . . . . . . . . . . .220
9007E5 . . . . . . . . . . .220
9007E6 . . . . . . . . . . .220
9007EA0S . . . . . . . .192
9007EA1 . . . . . . . . .190
9007EA11 . . . . . . . .190
9007EA11M . . . . . . .195
9007EA12 . . . . . . . .190
9007EA13 . . . . . . . .190
9007EA15 . . . . . . . .191
9007EA17 . . . . . . . .190
9007EA18 . . . . . . . .190
9007EA18M . . . . . . .195
9007EA1M . . . . . . . .195
9007EA1S . . . . . . . .192
9007EA2 . . . . . . . . .190
9007EA2S . . . . . . . .192
9007EA3 . . . . . . . . .193
9007EA3S . . . . . . . .193
9007EA4 . . . . . . . . .190
9007EA4S . . . . . . . .192
9007EA5 . . . . . . . . .191
9007EA5M . . . . . . . .195
9007EA6 . . . . . . . . .191
9007EA8 . . . . . . . . .190
9007EA8M . . . . . . . .195
9007EA9 . . . . . . . . .191
9007EA9M . . . . . . . .195
9007ED . . . . . . . . . .189
9007F . . . . . . . . . . .189
9007F4 . . . . . . . . . . .220
9007F5 . . . . . . . . . . .220
9007F6 . . . . . . . . . . .220
9007FA1 . . . . . . . . . .194
9007FA2 . . . . . . . . . .193
9007FA3 . . . . . . . . . .194
9007FA5 . . . . . . . . . .194
9007FA6 . . . . . . . . . .194
9007FT••• . . . . . . . . . .11
9007FTUA1 . . . . . . .218
9007FTUA10 . . . . . .218
9007FTUA11 . . . . . .218
9007FTUA12 . . . . . .218
9007FTUA2 . . . . . . .218
9007FTUA3 . . . . . . .218
9007FTUA4 . . . . . . .218
9007FTUA5 . . . . . . .218
9007FTUA6 . . . . . . .218
9007FTUA7 . . . . . . .218
9007FTUA8 . . . . . . .218
9007FTUA9 . . . . . . .218
9007FTUB1 . . . . . . .218
9007FTUB10 . . . . . .218
9007FTUB11 . . . . . .218
9007FTUB12 . . . . . .218
9007FTUB2 . . . . . . .218
9007FTUB3 . . . . . . .218
9007FTUB4 . . . . . . . 218
9007FTUB5 . . . . . . . 218
9007FTUB6 . . . . . . . 218
9007FTUB7 . . . . . . . 218
9007FTUB8 . . . . . . . 218
9007FTUB9 . . . . . . . 218
9007FTUC1 . . . . . . . 218
9007FTUC10 . . . . . . 218
9007FTUC11 . . . . . . 218
9007FTUC12 . . . . . . 218
9007FTUC2 . . . . . . . 218
9007FTUC3 . . . . . . . 218
9007FTUC4 . . . . . . . 218
9007FTUC5 . . . . . . . 218
9007FTUC6 . . . . . . . 218
9007FTUC7 . . . . . . . 218
9007FTUC8 . . . . . . . 218
9007FTUC9 . . . . . . . 218
9007FTUD1 . . . . . . . 218
9007FTUD10 . . . . . . 218
9007FTUD11 . . . . . . 218
9007FTUD12 . . . . . . 218
9007FTUD2 . . . . . . . 218
9007FTUD3 . . . . . . . 218
9007FTUD4 . . . . . . . 218
9007FTUD5 . . . . . . . 218
9007FTUD6 . . . . . . . 218
9007FTUD7 . . . . . . . 218
9007FTUD8 . . . . . . . 218
9007FTUD9 . . . . . . . 218
9007G . . . . . . . . . . . 189
9007G10 . . . . . . . . . 221
9007GD . . . . . . . . . 189
9007H . . . . . . . . . . . 189
9007HA0 . . . . . . . . . 194
9007HA1 . . . . . . . . . 194
9007HA2 . . . . . . . . . 194
9007HA20 . . . . . . . . 194
9007HA21 . . . . . . . . 194
9007HA22 . . . . . . . . 194
9007HA23 . . . . . . . . 194
9007HA24 . . . . . . . . 194
9007HA25 . . . . . . . . 194
9007HA26 . . . . . . . . 194
9007HA4 . . . . . . . . . 194
9007HA5 . . . . . . . . . 194
9007HA6 . . . . . . . . . 194
9007HA8 . . . . . . . . . 194
9007HA9 . . . . . . . . . 194
9007J . . . . . . . . . . 189
9007J1 . . . . . . . . . . 220
9007J2 . . . . . . . . . . 220
9007JKC . . . . . . . . 189
9007K . . . . . . . . . . . 189
9007K1 . . . . . . . . . . 220
9007K2 . . . . . . . . . . 220
9007KA1 . . . . . . . . . 193
9007KA11 . . . . . . . . 193
9007KA12 . . . . . . . . 193
9007KA18 . . . . . . . . 193
9007KA2 . . . . . . . . . 193
9007KA21 . . . . . . . . 193
9007KA9 . . . . . . . . . 193
9007KB11 . . . . . . . . 193
9007KB15 . . . . . . . . .193
9007KC . . . . . . . . . .189
9007L . . . . . . . . . . .189
9007LA1 . . . . . . . . . .192
9007LA10 . . . . . . . . .192
9007LA11 . . . . . . . . .192
9007LA12 . . . . . . . . .192
9007LA16 . . . . . . . . .192
9007LA17 . . . . . . . . .192
9007LA18 . . . . . . . . .192
9007LA19 . . . . . . . . .194
9007LA2 . . . . . . . . . .192
9007LA3 . . . . . . . . . .192
9007LA4 . . . . . . . . . .192
9007LA5 . . . . . . . . . .192
9007LA6 . . . . . . . . . .192
9007LA7 . . . . . . . . . .192
9007LA8 . . . . . . . . . .192
9007LA9 . . . . . . . . . .192
9007MA1 . . . . . . . . .190
9007MA11 . . . . . . .190
9007MA11M . . . . . . .195
9007MA12 . . . . . . . .190
9007MA13 . . . . . . . .190
9007MA15 . . . . . . . .191
9007MA17 . . . . . . . .190
9007MA18 . . . . . . . .190
9007MA18M . . . . . . .195
9007MA18S . . . . . . .192
9007MA1M . . . . . . . .195
9007MA2 . . . . . . . . .190
9007MA22 . . . . . . . .191
9007MA3 . . . . . . . . .193
9007MA31 . . . . . . . .191
9007MA4 . . . . . . . . .190
9007MA5 . . . . . . . . .191
9007MA5M . . . . . . . .195
9007MA6 . . . . . . . . .191
9007MA8 . . . . . . . . .190
9007MA8M . . . . . . . .195
9007MA9 . . . . . . . . .191
9007MA9M . . . . . . . .195
9007N . . . . . . . . . . . .189
9007N1 . . . . . . . . . . .220
9007N2 . . . . . . . . . . .220
9007R . . . . . . . . . . .189
9007R16 . . . . . . . . . .221
9007R17 . . . . . . . . . .221
9007R18 . . . . . . . . . .220
9007R19 . . . . . . . . . .220
9007R20 . . . . . . . . . .220
9007R21 . . . . . . . . . .221
9007R22 . . . . . . . . . .221
9007RA11 . . . . . . . .193
9007RA18 . . . . . . . .193
9007RA9 . . . . . . . . .193
9007S9 . . . . . . . . . . .181
9007T••• . . . . . . . . . . .10
9007T10 . . . . . . . . . .189
9007T5 . . . . . . . . . . .189
9007TSA1 . . . . . . . .217
9007TSA2 . . . . . . . .217
9007TSA3 . . . . . . . .217
9007TSB1 . . . . . . . .217
9007TSB2 . . . . . . . . 217
9007TSB3 . . . . . . . . 217
9007TSC1 . . . . . . . . 217
9007TSC2 . . . . . . . . 217
9007TSC3 . . . . . . . . 217
9007TSD1 . . . . . . . . 217
9007TSD2 . . . . . . . . 217
9007TSD3 . . . . . . . . 217
9007TUA1 . . . . . . . . 216
9007TUA10 . . . . . . . 216
9007TUA11 . . . . . . . 216
9007TUA12 . . . . . . . 216
9007TUA2 . . . . . . . . 216
9007TUA3 . . . . . . . . 216
9007TUA4 . . . . . . . . 216
9007TUA5 . . . . . . . . 216
9007TUA6 . . . . . . . . 216
9007TUA7 . . . . . . . . 216
9007TUA8 . . . . . . . . 216
9007TUA9 . . . . . . . . 216
9007TUB1 . . . . . . . . 216
9007TUB10 . . . . . . . 216
9007TUB11 . . . . . . . 216
9007TUB12 . . . . . . . 216
9007TUB2 . . . . . . . . 216
9007TUB3 . . . . . . . . 216
9007TUB4 . . . . . . . . 216
9007TUB5 . . . . . . . . 216
9007TUB6 . . . . . . . . 216
9007TUB7 . . . . . . . . 216
9007TUB8 . . . . . . . . 216
9007TUB9 . . . . . . . . 216
9007TUC1 . . . . . . . . 216
9007TUC10 . . . . . . . 216
9007TUC11 . . . . . . . 216
9007TUC12 . . . . . . . 216
9007TUC2 . . . . . . . . 216
9007TUC3 . . . . . . . . 216
9007TUC4 . . . . . . . . 216
9007TUC5 . . . . . . . . 216
9007TUC6 . . . . . . . . 216
9007TUC7 . . . . . . . . 216
9007TUC8 . . . . . . . . 216
9007TUC9 . . . . . . . . 216
9007TUD1 . . . . . . . . 216
9007TUD10 . . . . . . . 216
9007TUD11 . . . . . . . 216
9007TUD12 . . . . . . . 216
9007TUD2 . . . . . . . . 216
9007TUD3 . . . . . . . . 216
9007TUD4 . . . . . . . . 216
9007TUD5 . . . . . . . . 216
9007TUD6 . . . . . . . . 216
9007TUD7 . . . . . . . . 216
9007TUD8 . . . . . . . . 216
9007TUD9 . . . . . . . . 216
9007WJ . . . . . . . . . . 189
9007WK . . . . . . . . . . 189
9007WKC . . . . . . . . 189
9007X1 . . . . . . . . . . 220
9007X2 . . . . . . . . . . 220
9007Y1 . . . . . . . . . . 220
9007Y2 . . . . . . . . . . 220
9007Y3 . . . . . . . . . . 221
242
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Sensors, Limit Switches, and Connector Cables
Index
Limit Switches
9007Z1 . . . . . . . . . . 220
9007Z2 . . . . . . . . . . 220
AA . . . . . . . . . . . . . . 234
AB . . . . . . . . . . . . . . 234
AB1R11 . . . . . . . . . 92
AC . . . . . . . . . . . . . . 234
AD . . . . . . . . . . . . . . 234
AH . . . . . . . . . . . . . . 234
AJ . . . . . . . . . . . . . . 234
AK . . . . . . . . . . . . . . 234
AL . . . . . . . . . . . . . . 234
AL1649 . . . . . . . . . . 235
AL1650 . . . . . . . . . . 236
AL1650 . . . . . . . . . . 236
AL16501 . . . . . . . . . 236
AL1746 . . . . . . . . . . 235
AL1802 . . . . . . . . . . 236
AM . . . . . . . . . . . . . 234
AN . . . . . . . . . . . . . . 234
AO . . . . . . . . . . . . . . 234
AP . . . . . . . . . . . . . . 234
AQ . . . . . . . . . . . . . . 234
AR . . . . . . . . . . . . . . 234
BA . . . . . . . . . . . . . . 234
BB . . . . . . . . . . . . . . 234
BH . . . . . . . . . . . . . . 234
BH20-5-12 . . . . . . . 181
BH20512 . . . . . . . . . 237
BH20-5-3 . . . . . . . . 181
BH2053 . . . . . . . . . . 237
BH20-5-6 . . . . . . . . 181
BH2056 . . . . . . . . . . 237
BM . . . . . . . . . . . . . 234
BN . . . . . . . . . . . . . . 234
BO . . . . . . . . . . . . . . 234
BQ . . . . . . . . . . . . . . 234
BR . . . . . . . . . . . . . . 234
CA . . . . . . . . . . . . . . 234
CB . . . . . . . . . . . . . . 234
CC . . . . . . . . . . . . . . 234
CD . . . . . . . . . . . . . . 234
CH . . . . . . . . . . . . . . 234
CL . . . . . . . . . . . . . . 234
CM . . . . . . . . . . . . . 234
CO . . . . . . . . . . . . . 234
CR . . . . . . . . . . . . . . 234
DE9RA1012 . . . . . . . 74
DE9RA1212 . . . . . . 133
DE9RA1212 . . . . . . 139
DE9RA1212 . . . . . . 141
DE9RA13520 . . . . . 139
DE9RA13520 . . . . . 141
EA . . . . . . . . . . . . . . 235
EB . . . . . . . . . . . . . . 235
ED . . . . . . . . . . . . . . 235
FA . . . . . . . . . . . . . . 235
FB . . . . . . . . . . . . . . 235
FC . . . . . . . . . . . . . . 235
FE . . . . . . . . . . . . . . 235
FG . . . . . . . . . . . . . . 235
FI . . . . . . . . . . . . . . . 235
FJ . . . . . . . . . . . . . . 235
KA . . . . . . . . . . . . . . 235
KB . . . . . . . . . . . . . . 235
KO . . . . . . . . . . . . . . 235
L100••• . . . . . . . . . . . . 10
L100WDL2M7 . . . . . 228
L100WDL2M8 . . . . . 228
L100WDR2M4 . . . . . 228
L100WDR2M5 . . . . . 228
L100WDR2M6 . . . . . 228
L100WN2M16 . . . . . 228
L100WN2M17 . . . . . 228
L100WNC2M18 . . . . 229
L100WNCS2M34 . . . 229
L100WNS2M26 . . . . 229
L100WNSL2M29 . . . 229
L100WNSR2M28 . . . 229
L100WS02M22 . . . . 229
L100WS02M23 . . . . 229
L100WS0S2M60 . . . 233
L100WS2M1 . . . . . . 228
L100WS2M2 . . . . . . 228
L100WS2M3 . . . . . . 228
L100WTL2M13 . . . . 228
L100WTL2M14 . . . . 228
L100WTL2M15 . . . . 228
L100WTLN1C2M39 . 229
L100WTLN2M21 . . . 229
L100WTLN2M41 . . . 229
L100WTR2M10 . . . . 228
L100WTR2M11 . . . . 228
L100WTR2M12 . . . . 228
L100WTRN1C2M38 229
L100WTRN2C2M40 229
L100WTRN2CS2M48 229
L100WTRN2M20 . . . 229
L14 . . . . . . . . . . . . . . . 10
L142 . . . . . . . . . . . . . 232
L143 . . . . . . . . . . . . . 232
L144 . . . . . . . . . . . . . 232
L145 . . . . . . . . . . . . . 232
L146 . . . . . . . . . . . . . 232
L147 . . . . . . . . . . . . . 232
L148 . . . . . . . . . . . . . 232
L149 . . . . . . . . . . . . . 232
L2153 . . . . . . . . . . . . . 11
L2153 . . . . . . . . . . . . 232
L300••• . . . . . . . . . . . . 11
L300WDL2M7 . . . . . 230
L300WDL2M8 . . . . . 230
L300WDR2M4 . . . . . 230
L300WDR2M5 . . . . . 230
L300WDR2M6 . . . . . 230
L300WN2M16 . . . . . 230
L300WN2M17 . . . . . 230
L300WNC2M18 . . . . 231
L300WNCS2M34 . . . 231
L300WNS2M26 . . . . 231
L300WNSL2M29 . . . 231
L300WNSR2M28 . . . 231
L300WS02M22 . . . . 231
L300WS02M23 . . . . 231
L300WS2M1 . . . . . . 230
L300WS2M2 . . . . . . 230
L300WS2M3 . . . . . . 230
L300WTL2M13 . . . . 230
L300WTL2M14 . . . . 230
L300WTL2M15 . . . . 230
L300WTLN1C2M39 231
L300WTLN2M21 . . . 231
L300WTLN2M41 . . . 231
L300WTR2M10 . . . . 230
L300WTR2M11 . . . . 230
L300WTR2M12 . . . . 230
L300WTRN1C2M38 231
L300WTRN2C2M40 231
L300WTRN2CS2M48 231
L300WTRN2M20 . . 231
L525 . . . . . . . . . . . . . 10
L525WDL2M57 . . . . 233
L525WDL2M58 . . . . 233
L525WDR2M56 . . . 233
L525WDR2M59 . . . 233
LA01 . . . . . . . . . . . . 236
LAA1 . . . . . . . . . . . . 236
LAH1 . . . . . . . . . . . . 236
LCA1 . . . . . . . . . . . . 236
LCH1 . . . . . . . . . . . . 236
LCO1 . . . . . . . . . . . 236
M11 . . . . . . . . . . . . . 221
ML01S0100 . . . . . . 156
ML02S0100 . . . . . . 156
ML03S0100 . . . . . . 156
ML04S0100 . . . . . . 156
ML06S0100 . . . . . . 156
ML07S0100 . . . . . . 156
ML08S0100 . . . . . . 156
ML09S0100 . . . . . . 156
ML10S0100 . . . . . . 157
ML12S0100 . . . . . . 157
ML13S0100 . . . . . . 157
MS01G0100 . . . . . . 156
MS01S0100 . . . . . . 156
MS02G0100 . . . . . . 156
MS02S0100 . . . . . . 156
MS03G0100 . . . . . . 156
MS03S0100 . . . . . . 156
MS04G0100 . . . . . . 156
MS04S0100 . . . . . . 156
MS05G0100 . . . . . . 156
MS05S0100 . . . . . . 156
MS06G0100 . . . . . . 156
MS06S0100 . . . . . . 156
MS07G0100 . . . . . . 156
MS07S0100 . . . . . . 156
MS08G0100 . . . . . . 156
MS08S0100 . . . . . . 156
MS09G0100 . . . . . . 156
MS09S0100 . . . . . . 156
MS10G0100 . . . . . . 157
MS10S0100 . . . . . . 157
MS12G0100 . . . . . . 157
MS12S0100 . . . . . . 157
MS13G0100 . . . . . . 157
MS13S0100 . . . . . . 157
R . . . . . . . . . . . . . . . 236
R9 . . . . . . . . . . . . . . 236
VA . . . . . . . . . . . . . . 236
XALZ09 . . . . . . . . . . . 74
XCKD2101G11 . . . . . 74
XCKD2101M12 . . . . . 74
XCKD2101N12 . . . . . 74
XCKD2501G11 . . . . . 74
XCKD2501N12 . . . . . 74
XCKML . . . . . . . . . . . . 7
XCKP2101G11 . . . . . 74
XCKP2101M12 . . . . . 74
XCKP2101N12 . . . . . 74
XCKP2501G11 . . . . . 74
XCKP2501N12 . . . . . 74
XCKS . . . . . . . . . . . . . . 7
XCKZ09 . . . . . . . . . . 92
XCMD2101C12 . . . . . 45
XCMD2101L1 . . . . . . 45
XCMD2101M12 . . . . . 45
XCMD2501L1 . . . . . . 45
XCMZ06 . . . . . . . . . . 45
XCMZ07 . . . . . . . . . . . 45
XCMZ07 . . . . . . . . . . . 74
XCR, XC1AC . . . . . . . . 7
XCRZ02 . . . . . . . . . . 139
XCRZ03 . . . . . . . . . . 139
XCRZ04 . . . . . . . . . . 139
XCRZ05 . . . . . . . . . . 139
XCRZ09 . . . . . . . . . . 139
XCRZ09 . . . . . . . . . . 141
XCRZ12 . . . . . . . . . . 139
XCRZ15 . . . . . . . . . . 139
XCRZ42 . . . . . . . . . . 141
XCRZ901 . . . . . . . . . 141
XCRZ902 . . . . . . . . . 141
XCRZ903 . . . . . . . . . 141
XE2N P2131 . . . . . . 120
XE2N P2131 . . . . . . 133
XE2N P2141 . . . . . . 120
XE2N P2141 . . . . . . 133
XE2N P2151 . . . . . 120
XE2N P2151 . . . . . 133
XE2N P2161 . . . . . . 120
XE2N P2161 . . . . . . 133
XE2NP2131 . . . . . . . 116
XE2NP2131 . . . . . . . 119
XE2NP2131 . . . . . . . . 75
XE2NP2131 . . . . . . . . 92
XE2NP2141 . . . . . . . 116
XE2NP2141 . . . . . . . 119
XE2NP2141 . . . . . . . . 75
XE2NP2141 . . . . . . . . 92
XE2NP2151 . . . . . . . 92
XE2NP2151 . . . . . . . 116
XE2NP2151 . . . . . . . 119
XE2NP2151 . . . . . . . . 75
XE2NP2161 . . . . . . . 116
XE2NP2161 . . . . . . . 119
XE2NP2161 . . . . . . . . 75
XE2NP2161 . . . . . . . . 92
XE2NP3131 . . . . . . . . 75
XE2NP3141 . . . . . . . . 75
XE2NP3151 . . . . . . . . 75
XE2NP3161 . . . . . . . . 75
XE2S P2141 . . . . . . 120
XE2S P2141 . . . . . . 133
XE2S P2151 . . . . . 120
XE2S P2151 . . . . . 133
XE2SP2141 . . . . . . . 116
Sensors, Limit Switches, and Connector Cables
Index
243
03/2007 © 1997–2007 Schneider Electric All Rights Reserved
Limit Switches
XE2SP2141 . . . . . . .119
XE2SP2141 . . . . . . . .75
XE2SP2141 . . . . . . . .92
XE2SP2151 . . . . . . .92
XE2SP2151 . . . . . . .116
XE2SP2151 . . . . . . .119
XE2SP2151 . . . . . . . .75
XE2SP3151 . . . . . . . .75
XE3N P2141 . . . . . .120
XE3N P2141 . . . . . .133
XE3N P2151 . . . . . .120
XE3N P2151 . . . . . .133
XE3NP2141 . . . . . . . .75
XE3NP2141 . . . . . . . .92
XE3NP2151 . . . . . . . .75
XE3NP2151 . . . . . . . .92
XE3S P2141 . . . . . . .120
XE3S P2141 . . . . . . .133
XE3S P2151 . . . . . .120
XE3S P2151 . . . . . .133
XE3SP2141 . . . . . . . .75
XE3SP2141 . . . . . . . .92
XE3SP2151 . . . . . . .92
XE3SP2151 . . . . . . . .75
XEP, XCO . . . . . . . . . .7
XEP3S1W2 . . . . . . . .28
XEP3S1W2B524 . . . .28
XEP3S1W2B529 . . . .28
XEP3S1W3 . . . . . . . .28
XEP3S1W3B524 . . . .28
XEP3S1W3B529 . . . .28
XEP3S1W6 . . . . . . . .28
XEP3S1W6B524 . . . .28
XEP3S1W6B529 . . . .28
XEP3S2W2 . . . . . . . .28
XEP3S2W2B524 . . . .28
XEP3S2W2B529 . . . .28
XEP3S2W3 . . . . . . . .28
XEP3S2W3B524 . . . .28
XEP3S2W3B529 . . . .28
XEP3S2W6 . . . . . . . .28
XEP3S2W6B524 . . . .28
XEP3S2W6B529 . . . .28
XEP4E1FD (3) . . . . . .26
XEP4E1FDA326 (3) . .26
XEP4E1FDA454 (3) . .26
XEP4E1W7 (3) . . . . . .26
XEP4E1W7A326 (3) .26
XEP4E1W7A454 (3) .26
XEP5P1W2 (3) . . . . . .26
XEP5P1W2Z55B (3) .26
XES P2021 . . . . . . .120
XES P2031 . . . . . . . .120
XES P3021 . . . . . . .133
XESP2021 . . . . . . . .116
XESP20215 . . . . . . .119
XESP2031 . . . . . . . .116
XESP20315 . . . . . . .119
XZCP1164L10 . . . . .104
XZCP1164L10 . . . . . .46
XZCP1164L2 . . . . . .104
XZCP1164L2 . . . . . . .46
XZCP1164L5 . . . . . .104
XZCP1164L5 . . . . . . .46
XZCP1169L10 . . . . . . 46
XZCP1169L2 . . . . . . . 46
XZCP1169L5 . . . . . . . 46
XZCP1264L10 . . . . . 104
XZCP1264L10 . . . . . . 46
XZCP1264L2 . . . . . . 104
XZCP1264L2 . . . . . . . 46
XZCP1264L5 . . . . . . 104
XZCP1264L5 . . . . . . . 46
XZCP1771L10 . . . . . 106
XZCP1771L10 . . . . . . 46
XZCP1771L2 . . . . . . 106
XZCP1771L2 . . . . . . . 46
XZCP1771L5 . . . . . . 106
XZCP1771L5 . . . . . . . 46
Y147 . . . . . . . . . . . . 180
Y1561 . . . . . . . . . . . 180
Y1841 . . . . . . . . . . 179
Y1842 . . . . . . . . . . . 179
Y1843 . . . . . . . . . . . 179
Y1844 . . . . . . . . . . . 179
Y1851 . . . . . . . . . . . 179
Y1852 . . . . . . . . . . . 179
Y1853 . . . . . . . . . . . 179
Y1854 . . . . . . . . . . . 179
Y1855 . . . . . . . . . . . 179
Y1856 . . . . . . . . . . . 179
Y1857 . . . . . . . . . . . 179
Y1858 . . . . . . . . . . . 179
Y1901 . . . . . . . . . . . 178
Y19013 . . . . . . . . . . 178
Y1903 . . . . . . . . . . . 178
Y1905 . . . . . . . . . . . 178
Y247 . . . . . . . . . . . . 180
Y249 . . . . . . . . . . . . 180
Y33 . . . . . . . . . . . . . 179
ZC1AC001 . . . . . 148
ZC1AC005 . . . . . 148
ZC1AC006 . . . . . 148
ZC1AC007 . . . . . 148
ZC1AC008 . . . . . 148
ZC1AC009 . . . . . . . 148
ZC1AZ11 . . . . . . . 148
ZC1AZ12 . . . . . . . . . 148
ZC1AZ13 . . . . . . . . . 148
ZC1AZ14 . . . . . . . . . 148
ZC1AZ15 . . . . . . . . . 148
ZC1AZ16 . . . . . . . . . 148
ZC1AZ17 . . . . . . . . . 148
ZC1AZ8 . . . . . . . . . . 148
ZCD21 . . . . . . . . . . . . 72
ZCD25 . . . . . . . . . . . . 72
ZCD26 . . . . . . . . . . . . 72
ZCD27 . . . . . . . . . . . . 72
ZCD28 . . . . . . . . . . . . 72
ZCD29 . . . . . . . . . . . . 72
ZCD31 . . . . . . . . . . . . 72
ZCD35 . . . . . . . . . . . . 72
ZCD37 . . . . . . . . . . . . 72
ZCD39 . . . . . . . . . . . . 72
ZCE05 . . . . . . . . . . . . 45
ZCE05 . . . . . . . . . . . . 74
ZCK Z020 . . . . . . . 121
ZCK Z021 . . . . . . . . 121
ZCK Z033 . . . . . . . . .121
ZCK Z034 . . . . . . . . .121
ZCKE055 . . . . . . . . .118
ZCKE056 . . . . . . . . .115
ZCKE065 . . . . . . . . .118
ZCKE066 . . . . . . . . .115
ZCKE085 . . . . . . . . .118
ZCKE086 . . . . . . . . .115
ZCKE095 . . . . . . . . .118
ZCKE096 . . . . . . . . .115
ZCKE215 . . . . . . . . .118
ZCKE216 . . . . . . . . .115
ZCKE235 . . . . . . . . .118
ZCKE236 . . . . . . . . .115
ZCKE615 . . . . . . . . .118
ZCKE616 . . . . . . . . .115
ZCKE625 . . . . . . . . .118
ZCKE626 . . . . . . . . .115
ZCKE635 . . . . . . . . .118
ZCKE636 . . . . . . . . .115
ZCKE645 . . . . . . . . .118
ZCKE646 . . . . . . . . .115
ZCKE655 . . . . . . . . .118
ZCKE656 . . . . . . . . .115
ZCKE665 . . . . . . . . .118
ZCKE675 . . . . . . . . .118
ZCKE676 . . . . . . . . .115
ZCKJ01 . . . . . . . . . .111
ZCKJ0121 . . . . . . .121
ZCKJ0133 . . . . . . . .121
ZCKJ0134 . . . . . . . .121
ZCKJ02 . . . . . . . . . .111
ZCKJ04 . . . . . . . . . .111
ZCKJ1 . . . . . . . . . . .110
ZCKJ1 . . . . . . . . . . .114
ZCKJ1 . . . . . . . . . . .117
ZCKJ11 . . . . . . . . . .111
ZCKJ11 . . . . . . . . . .114
ZCKJ1121 . . . . . . .112
ZCKJ1121H29 . . . . .112
ZCKJ1133 . . . . . . . .112
ZCKJ1133H29 . . . . .112
ZCKJ1134 . . . . . . . .112
ZCKJ1134H29 . . . . .112
ZCKJ115 . . . . . . . . .117
ZCKJ115H29 . . . . . .117
ZCKJ11H29 . . . . . . .111
ZCKJ11H29 . . . . . . .114
ZCKJ120 . . . . . . . .112
ZCKJ121 . . . . . . . . .112
ZCKJ121H29 . . . . . .112
ZCKJ133 . . . . . . . . .112
ZCKJ133H29 . . . . . .112
ZCKJ134 . . . . . . . . .112
ZCKJ134H29 . . . . . .112
ZCKJ1D . . . . . . . . .113
ZCKJ1H29 . . . . . . . .110
ZCKJ1H29 . . . . . . . .114
ZCKJ1H29 . . . . . . . .117
ZCKJ2 . . . . . . . . . . .110
ZCKJ2 . . . . . . . . . . .114
ZCKJ21 . . . . . . . . . .111
ZCKJ21 . . . . . . . . . .114
ZCKJ215 . . . . . . . . .117
ZCKJ215H29 . . . . . . 117
ZCKJ21H29 . . . . . . . 111
ZCKJ21H29 . . . . . . . 114
ZCKJ25 . . . . . . . . . . 117
ZCKJ25H29 . . . . . . . 117
ZCKJ2H29 . . . . . . . . 110
ZCKJ2H29 . . . . . . . . 114
ZCKJ4 . . . . . . . . . . . 110
ZCKJ4 . . . . . . . . . . . 114
ZCKJ404 . . . . . . . . . 111
ZCKJ4045 . . . . . . . . 117
ZCKJ4045H29 . . . . . 117
ZCKJ4046 . . . . . . . . 114
ZCKJ4046H29 . . . . . 114
ZCKJ404H29 . . . . . . 111
ZCKJ41 . . . . . . . . . . 111
ZCKJ41 . . . . . . . . . . 114
ZCKJ4104 . . . . . . . . 111
ZCKJ41045 . . . . . . . 117
ZCKJ41045H29 . . . . 117
ZCKJ41046 . . . . . . . 114
ZCKJ41046H29 . . . . 114
ZCKJ4104H29 . . . . . 111
ZCKJ415 . . . . . . . . . 117
ZCKJ415H29 . . . . . . 117
ZCKJ41H29 . . . . . . . 111
ZCKJ41H29 . . . . . . . 114
ZCKJ45 . . . . . . . . . . 117
ZCKJ45H29 . . . . . . . 117
ZCKJ4H29 . . . . . . . . 110
ZCKJ4H29 . . . . . . . . 114
ZCKJ5 . . . . . . . . . . . 110
ZCKJ5 . . . . . . . . . . . 114
ZCKJ5 . . . . . . . . . . . 117
ZCKJ520 . . . . . . . . . 112
ZCKJ521 . . . . . . . . . 112
ZCKJ521H29 . . . . . . 112
ZCKJ533 . . . . . . . . . 112
ZCKJ533H29 . . . . . . 112
ZCKJ534 . . . . . . . . . 112
ZCKJ534H29 . . . . . . 112
ZCKJ5D . . . . . . . . . . 113
ZCKJ5H29 . . . . . . . . 110
ZCKJ5H29 . . . . . . . . 114
ZCKJ5H29 . . . . . . . . 117
ZCKJ6 . . . . . . . . . . . 110
ZCKJ6 . . . . . . . . . . . 114
ZCKJ6 . . . . . . . . . . . 117
ZCKJ6D . . . . . . . . . . 113
ZCKJ6H29 . . . . . . . . 110
ZCKJ6H29 . . . . . . . . 114
ZCKJ6H29 . . . . . . . . 117
ZCKJ7 . . . . . . . . . . . 110
ZCKJ7 . . . . . . . . . . . 114
ZCKJ7 . . . . . . . . . . . 117
ZCKJ7D . . . . . . . . . . 113
ZCKJ7H29 . . . . . . . . 110
ZCKJ7H29 . . . . . . . . 114
ZCKJ7H29 . . . . . . . . 117
ZCKJ8 . . . . . . . . . . . 110
ZCKJ8 . . . . . . . . . . . 114
ZCKJ8 . . . . . . . . . . . 117
ZCKJ82A . . . . . . . . 121
ZCKJ8D . . . . . . . . . . 113
244
© 1997–2007 Schneider Electric All Rights Reserved 03/2007
Sensors, Limit Switches, and Connector Cables
Index
Limit Switches
ZCKJ8H29 . . . . . . . 110
ZCKJ8H29 . . . . . . . 114
ZCKJ8H29 . . . . . . . 117
ZCKJ9 . . . . . . . . . . . 110
ZCKJ9 . . . . . . . . . . . 114
ZCKJ9 . . . . . . . . . . . 117
ZCKJ902 . . . . . . . . 121
ZCKJ903 . . . . . . . . . 121
ZCKJ904 . . . . . . . . . 121
ZCKJ906 . . . . . . . . . 121
ZCKJ9H29 . . . . . . . 110
ZCKJ9H29 . . . . . . . 114
ZCKJ9H29 . . . . . . . 117
ZCKJD31 . . . . . . . . 110
ZCKJD31H29 . . . . . 110
ZCKJD35 . . . . . . . . 110
ZCKJD35H29 . . . . . 110
ZCKJD37 . . . . . . . . 110
ZCKJD37H29 . . . . . 110
ZCKJD39 . . . . . . . . 110
ZCKJD39H29 . . . . . 110
ZCKL1 . . . . . . . . . . . 90
ZCKL5 . . . . . . . . . . . . 90
ZCKL6 . . . . . . . . . . . . 90
ZCKL7 . . . . . . . . . . . . 90
ZCKL8 . . . . . . . . . . . . 90
ZCKLD31 . . . . . . . . . 91
ZCKLD35 . . . . . . . . . 91
ZCKLD37 . . . . . . . . . 91
ZCKLD39 . . . . . . . . . 91
ZCKM1 . . . . . . . . . . . 90
ZCKM1H29 . . . . . . . . 90
ZCKM5 . . . . . . . . . . . 90
ZCKM5H29 . . . . . . . . 90
ZCKM6 . . . . . . . . . . . 90
ZCKM6H29 . . . . . . . . 90
ZCKM7 . . . . . . . . . . . 90
ZCKM7H29 . . . . . . . . 90
ZCKM8 . . . . . . . . . . . 90
ZCKM8H29 . . . . . . . . 90
ZCKM9H29 . . . . . . . . 90
ZCKMD31 . . . . . . . . . 91
ZCKMD31H29 . . . . . 91
ZCKMD35 . . . . . . . . . 91
ZCKMD35H29 . . . . . 91
ZCKMD37 . . . . . . . . . 91
ZCKMD37H29 . . . . . 91
ZCKMD39 . . . . . . . . . 91
ZCKMD39H29 . . . . . 91
ZCKS1 . . . . . . . . . 132
ZCKS1H29 . . . . . . . 132
ZCKS2 . . . . . . . . . . 132
ZCKS2H29 . . . . . . . 132
ZCKS404 . . . . . . . 132
ZCKS404H29 . . . . . 132
ZCKS5 . . . . . . . . . . 132
ZCKS5H29 . . . . . . . 132
ZCKS6 . . . . . . . . . . 132
ZCKS6H29 . . . . . . . 132
ZCKS7 . . . . . . . . . . 132
ZCKS7H29 . . . . . . . 132
ZCKS8 . . . . . . . . . . 132
ZCKS8H29 . . . . . . . 132
ZCKS9 . . . . . . . . . . 132
ZCKS9H29 . . . . . . . . 132
ZCKSD31 . . . . . . . . . 132
ZCKSD31H29 . . . . . 132
ZCKSD35 . . . . . . . . . 132
ZCKSD35H29 . . . . . 132
ZCKSD37 . . . . . . . . . 132
ZCKSD37H29 . . . . . 132
ZCKSD39 . . . . . . . . . 132
ZCKSD39H29 . . . . . 132
ZCKY11 . . . . . . . . . . 116
ZCKY115 . . . . . . . . . 119
ZCKY13 . . . . . . . . . . 116
ZCKY13 . . . . . . . . . . 119
ZCKY14 . . . . . . . . . . 116
ZCKY14 . . . . . . . . . . 119
ZCKY41 . . . . . . . . . . 116
ZCKY415 . . . . . . . . . 119
ZCKY43 . . . . . . . . . . 116
ZCKY43 . . . . . . . . . . 119
ZCKY51 . . . . . . . . . . 116
ZCKY51 . . . . . . . . . . 119
ZCKY52 . . . . . . . . . . 116
ZCKY52 . . . . . . . . . . 119
ZCKY53 . . . . . . . . . . 116
ZCKY53 . . . . . . . . . . 119
ZCKY59 . . . . . . . . . . 116
ZCKY61 . . . . . . . . . . 116
ZCKY615 . . . . . . . . . 119
ZCKY71 . . . . . . . . . . 116
ZCKY715 . . . . . . . . . 119
ZCKY81 . . . . . . . . . . 116
ZCKY91 . . . . . . . . . . 116
ZCMC21E1 . . . . . . . . 44
ZCMC21E10 . . . . . . . 44
ZCMC21E2 . . . . . . . . 44
ZCMC21E3 . . . . . . . . 44
ZCMC21E5 . . . . . . . . 44
ZCMC21E7 . . . . . . . . 44
ZCMC21L1 . . . . . . . . 43
ZCMC21L10 . . . . . . . 43
ZCMC21L2 . . . . . . . . 43
ZCMC21L3 . . . . . . . . 43
ZCMC21L5 . . . . . . . . 43
ZCMC21L7 . . . . . . . . 43
ZCMC25L1 . . . . . . . . 43
ZCMC25L10 . . . . . . . 43
ZCMC25L2 . . . . . . . . 43
ZCMC25L3 . . . . . . . . 43
ZCMC25L5 . . . . . . . . 43
ZCMC25L7 . . . . . . . . 43
ZCMD61 . . . . . . . . . . 44
ZCMD61C12 . . . . . . . 45
ZCMD61M12 . . . . . . . 45
ZCMD65 . . . . . . . . . . 44
ZCMD69 . . . . . . . . . . 44
ZCMD69C12 . . . . . . . 45
ZCMD77 . . . . . . . . . . 44
ZCMD79 . . . . . . . . . . 44
ZCMD81L1 . . . . . . . . 44
ZCMD81L2 . . . . . . . . 44
ZCMD81L5 . . . . . . . . 44
ZCP21 . . . . . . . . . . . . 72
ZCP25 . . . . . . . . . . . . 72
ZCP26 . . . . . . . . . . . . 72
ZCP27 . . . . . . . . . . . . 72
ZCP28 . . . . . . . . . . . . 72
ZCP29 . . . . . . . . . . . . 72
ZCP31 . . . . . . . . . . . . 72
ZCP35 . . . . . . . . . . . . 72
ZCP37 . . . . . . . . . . . . 72
ZCP39 . . . . . . . . . . . . 72
ZCT21G11 . . . . . . . . 73
ZCT21N12 . . . . . . . . 73
ZCT21P16 . . . . . . . . 73
ZCT25G11 . . . . . . . . 73
ZCT25N12 . . . . . . . . 73
ZCT25P16 . . . . . . . . 73
ZCT26G11 . . . . . . . . 73
ZCT26N12 . . . . . . . . 73
ZCT26P16 . . . . . . . . 73
ZCT27G11 . . . . . . . . 73
ZCT27N12 . . . . . . . . 73
ZCT27P16 . . . . . . . . 73
ZCT28G11 . . . . . . . . 73
ZCT28N12 . . . . . . . . 73
ZCT28P16 . . . . . . . . 73
ZEP3L524 . . . . . . . . . 28
ZEP3L529 . . . . . . . . . 28
ZEP4L326 (3) . . . . . . 26
ZEP4L454 (3) . . . . . . 26
9007CT0501 © 1997–2006 Schneider Electric All Rights Reserved
8001 Knightdale Blvd.
Knightdale, NC 27545
1-888-Square D
1-888-778-2733
www.us.SquareD.com
03/2007
Schneider Electric USA
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Schneider Electric:
XCKJ10511H7 XCKP2121M12 XCKP2127N12 XCKP2145M12 XCKT2110N12 XCKT2121N12 XCKT2145N12
XCMD2102L3 XCMD2110L3 XCMD2124L1 XCKJ161H7 XCKL106H7 XCKL121H7 XCKM110H7 XCKP2106N12
XCKP2110N12 XCKD2102N12 XCKD2106N12 XCKD2110N12 XCKD2118N12 XCKD2121N12 XCKJ167H7