Burndy Solderless Terminals YAV 2TC, YA L2L, 2LN, L 2TC Catalog Page Brochure
104369-Brochure 104369-Brochure 104369-Brochure 781810 Batch6 unilog cesco-content
2016-07-29
: Pdf 1000375942-Brochure 1000375942-Brochure B2 unilog
Open the PDF directly: View PDF
.
Page Count: 4

Conductor ▲Installation Tooling
Stud
Stud
Figure Mechanical Hydraulic Wire
Fig *** Hole
Hole Tongue
Dimensions Dieless MD6, OUR840, BCT500HS, Y35, Y39, Y750, Color Die Strip
Catalog Number # AWG MM2Size
Spacing Width
(B) (T) (L) (# of crimps) MD7-34R Y500CTHS Y46*, PAT750 Code Index Length
YAV10-2TC10 1 # 10 5/8.38.38.061.72
YAV10-2TC14 11/45/8.47.38.061.84
YAV10-2TC14E1 1
#14-10 Str.
61/41.47.38.052.22Y8MRB-1 (1) — — — — — 7/16
YAV10-2TC14E2 1
#12-10 Sol.
1/43/4.47.38.051.97
YAV10-2TC38 13/81.56.38.042.40
YA8CL-2TC10 1 # 10 5/8.41.44.081.83Y1MRTC (1)
YA8CL-2TC10E2 1 # 10 3/4.41.44.081.95Y8MRB-1 (1)
YA8CL-2TC14 1 #8 AWG 1/45/8.44.44.081.95MY29-3 (1)
#8 Weld † MY29-11 (1) W8CVT (1) W8CVT (1)
YA8CL-2TC14E1 137/24 10 1/41.44.44.082.33MRC840 (1) W8CRT (1) W8CRT (1) U8CRT (1) Red 49 1/2
YA8CL-2TC14E2 1 #6 Sol. 1/43/4.44.44.082.08Y81KFT (1) X8CRT (1) X8CRT (1)
YA8CL-2TC38 13/81.57.44.062.52
Y81KFTMBH (1)
YA8C-2LN 11/21-3/4.83.44.123.75
PAT81KFT-18V (1)
YA6C-2L 11/45/8.45.54.082.01
YA6C-2LN 11/21-3/4.81.54.123.87
YA6CL-2TC10 1 # 10 5/8.42.54.091.94
YA6CL-2TC14 11/45/8.45.54.082.07Y1MRTC (1)
YA6CL-2TC14E 11/41/2.45.54.081.94MY29-3 (1)
YA6CL-2TC14E1 11/41.45.54.082.44MY29-11 (1) W5CVT (1) W5CVT (1)
YA6CL-2TC14E2 16 AWG — 1/43/4.44.54.082.19MRC840 (1) W5CRT (1) W5CRT (1) U5CRT (1) Blue 7 5/8
YA6CL-2TC38 13/81.63.54.062.63Y81KFT (1) X5CRT (1) X5CRT (1) U8CABT (1)
YA6C-2L51 1 # 10 1/2.42.54.091.79
Y81KFTMBH (1)
X8CART (1) X8CART (1)
YA6CL-2TC516 15/161.52.54.072.51
PAT81KFT-18V (1)
YA6CL-2TC516E2 15/163/4.52.54.072.26
YA6C-2L52 11/41/2.45.54.081.88
YA5C-2L 1 5 AWG — 1/45/8.44.81.072.287/8
TWO HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
TYPES YAV-2TC, YA-L2L,
YA-2LN, AND YA-L-2TC
COPPER COMPRESSION
TERMINAL
UL Listed 90° C,
600 Volts to 35 kV ◆
45° and 90° angles are available.
Please contact Customer Service to order:
1-800-346-4175
-- Color code not assigned.
* Use PUADP-1 adapter with U dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
ELECTRO-TIN
PLATED
CABLE
ACCOMMODATION
CRIMP
DIE AND COLOR
CODE INFORMATION
INSPECTION
WINDOW
BEVELED
ENTRY
TTT
BB
B
Fig. 1 45° 90°
*** The MM2conductor sizes listed are the recommendations
for Class 2 conductor.
† The MM2conductor size referenced here is for both Class
2 and Class 5.
▲See tooling section of this catalog for complete tool and
die listings.
◆For applications greater than 2000 volts consult cable
manufacturer for voltage stress relief instructions.
Note: All dimensions shown are for reference only.
Blue highlighted items are industry standard and most frequently ordered.
C-30
Compression Connections BURNDY®
Copper Compression — Code — Inspection Window

Conductor ▲Installation Tooling
Stud
Stud
Figure Mechanical Hydraulic Wire
Fig *** Hole
Hole Tongue
Dimensions Dieless MD6, OUR840, BCT500HS, Y35, Y39, Y750, Color Die Strip
Catalog Number # AWG MM2Size
Spacing Width
(B) (T) (L) (# of crimps) MD7-34R Y500CTHS Y46*, PAT750 Code Index Length
Y1MRTC (2)
YA4C-2L 11/45/8.49.81.092.30MY29-3 (1)
MY29-11 (1)
YA4CL-2TC14 11/45/8.49.81.092.36MRC840 (1) W4CVT (1) W4CVT (1) U4CRT (1)
4 AWG — Y644HS (1) W4CRT (1) W4CRT (1) U6CABT (1) Gray 8 7/8
YA4CL-2TC38 13/81.58.81.082.96Y81KFT (1) X4CRT (1) X4CRT (1)
Y81KFTMBH (1)
YA4CL-2TC14E1 11/41.49.81.092.74
PAT81KFT-18V (1)
YA4C-2LN 11/21-3/4.83.81.124.14
YA4CL-2TC14E2 1 4 AWG — 1/43/4.49.81.092.49W4CVT (1) X4CRT (1) U4CRT (1) Gray 8 7/8
YA4CL-2TC516 15/161.52.81.092.80
YA3CL-2TC14 11/45/8.55.81.092.45
YA3C-2L 13 AWG 25 5/165/8.55.88.092.64W3CRT (1) W3CRT (1) U3CRT (1)
White
9 15/16
YA3CL-2TC38 1#2 Sol. 3/81.58.88.083.06Y1MRTC (2)
YA2C-2L 15/163/4.60.88.112.67MY29-3 (1)
YA2C-2LN 11/21-3/4.83.88.114.27MY29-11 (1)
YA2CL-2TC14 11/45/8.60.88.112.47MRC840 (1) W2CVT (1) W2CVT (1)
YA2CL-2TC14E1 12 AWG351/41.60.88.112.85Y644HS (1) W2CRT (1) W2CRT (1) U2CRT (1)
Brown
10 15/16
YA2CL-2TC14E2 11/43/4.60.88.112.60Y81KFT (1) X2CRT (1) X2CRT (1)
YA2CL-2TC38 13/81.60.88.113.03
Y81KFTMBH (1)
YA2CL-2TC516 15/161.60.88.112.91
PAT81KFT-18V (1)
YA1C-2LN 11/21-3/4.81.88.124.32
YA1C-2L 15/167/8.68.88.102.82
W1CVT (1) W1CVT (1)
U1CRT-1 (1)
YA1CL-2TC14 11 AWG 50 1/45/8.68.88.102.51
W1CRT-1 (1) W1CRT-1 (1)
U4CABT (1)
Green
11 15/16
YA1CL-2TC14E2 11/43/4.68.88.102.64
X1CRT-1 (1) X1CRT-1 (1)
YA1CL-2TC38
1 — 3/81 .68.88.103.07W1CVT (1) X1CRT-1 (1) U1CRT (1) Green 11 15/16
YA25-2L
15/167/8.75.88.122.85
YA25-2LN
11/21-3/4.83.88.114.29
YA25L-2TC14
11/45/8.75.88.122.64W25VT (2) W25VT (2) U25RT (1)
YA25L-2TC14E1
11/0 AWG — 1/41.75.88.123.01W25RT (2) W25RT (2) U2CABT (1) Pink 12 15/16
YA25L-2TC14E2
11/43/4.75.88.122.66MY29-3 (1) X25RT (2) X25RT (2)
YA25L-2TC38
13/81.75.88.123.10MY29-11 (1)
YA26-2L
15/167/8.83.94.122.95MRC840 (2)
YA26-2LN
11/21-3/4.83.94.124.39Y644HS (1)
YA26L-2TC14
11/45/8.83.94.122.64Y81KFT (1) W26VT (2) W26VT (2)
YA26L-2TC14E1
12/0 AWG 70 1/41.83.94.123.01
Y81KFTMBH (1)
W26RT (2) W26RT (2) U26RT (1) Black 13 1
YA26L-2TC14E2
11/43/4.83.94.122.76
PAT81KFT-18V (1)
X26RT (2) X26RT (2)
YA26L-2TC38
13/81.83.94.123.20
YA27-2LN
11/21-3/4.911.00.134.48W27VT (2) W27VT (2)
YA27L-2TC14E2
1 3/0 AWG — 1/43/4.911.00.122.86W27RT (2) W27RT (2) U27RT (1)
Orange
14
1-1/16
YA27L-2TC38
13/81.911.00.123.30X27RT (3) X27RT (3)
TWO HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
(Continued)
UL Listed 90° C,
600 Volts to 35 kV ◆
45° and 90° angles are available.
Please contact Customer Service to order:
1-800-346-4175
-- Color code not assigned.
▲See tooling section of this catalog for complete tool and
die listings.
TTT
BB
B
Fig. 1 45° 90°
◆For applications greater than 2000 volts consult cable
manufacturer for voltage stress relief instructions.
* Use PUADP-1 adapter with U dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM2conductor sizes listed are the recommendations
for Class 2 conductor.
Note: All dimensions shown are for reference only.
Blue highlighted items are industry standard and most frequently ordered.
C-31
BURNDY®Compression Connections
Copper Compression — Code — Inspection Window

Conductor ▲Installation Tooling
Stud
Stud
Figure Mechanical Hydraulic Wire
Fig *** Hole
Hole Tongue
Dimensions Dieless MD6, OUR840, BCT500HS, Y35, Y39, Y750, Color Die Strip
Catalog Number # AWG MM2Size
Spacing Width
(B) (T) (L) (# of crimps) MD7-34R Y500CTHS Y46*, PAT750 Code Index Length
YA28L-2NTC516 1 5/161-3/41.02.88.143.84MY29-3 (1)
YA28-2LN 11/21-3/41.02.88.144.41MY29-11 (1)
YA28L-2TC14E1 11/411.02.88.143.03MRC840 (2) W28VT (2) W28VT (2)
4/0 AWG — Y644HS (1) W28RT (2) W28RT (2) U28RT (1) Purple 15 1-1/8
YA28L-2TC14E2 11/43/41.02.88.142.78Y81KFT (1) X28RT (3) X28RT (3)
YA28L-2TC38E2 13/83/41.02.88.142.97
Y81KFTMBH (1)
YA28L-2TC38 13/811.02.88.143.22
PAT81KFT-18V (1)
MY29-3 (1)
YA29-2LN 11/21-3/41.111.06.164.62MY29-11 (1)
Y644HS (1) W29VT (2) W29VT (2)
250 kcmil — Y81KFT (1) X29RT (4) W29RT (2) U29RT (1) Yellow 16 1-1/8
YA29L-2TC38 13/811.111.06’ .163.45
Y81KFTMBH (1)
X29RT (4)
PAT81KFT-18V (1)
YA30-2LN 11/21-3/41.201.03.164.63W30VT (2) U30RT (2)
YA30L-2TC-38 1300 kcmil 150 3/811.201.03.163.45W30VT (2) W30RT (2) U28ART (2) White 17 1
YA31-2LN 11/21-3/41.291.06.184.70
YA31L-2TC12 11/21-1/41.291.06.184.01
YA31L-2TC14E2 1 350 kcmil 185 1/43/41.291.06.183.07W31VT (2) W31VT (2) U31RT (2) Red 18 1-1/8
YA31L-2TC38 13/811.291.06.183.51W31RT (2) U29ART (2)
YA31L-2NTC516 15/161-3/41.291.06.184.13
YA32-2LN 11/21-3/41.381.19.194.88
YA32L-2TC38E5
13/8
1-1/16
1.40
1.19
.19
3.75
W32VT (2) U32RT (2)
YA32L-2TC38
1400 kcmil — 3/
81
1.38
1.19
.19
3.69
W32VT (2) W32RT (2) U30ART (2) Blue 19 1-1/4
YA32-2L
13/8
1
1.40
1.19
.19
3.75
Y644HS (1)
Y81KFT (1)
W33VT (2)
326 or
YA33-2LN
1 450 kcmil — 1/2
1-3/4
1.48
1.50
.21
5.23
Y81KFTMBH (1)
W33VT (2) W33RT (2) U33RT (2) Gray 538
1-9/16
YA34-2LN
11/2
1-3/4
1.52
1.27
.23
5.06
PAT81KFT-18V (1)
YA34L-2TC12
11/2
1-1/4
1.52
1.27
.23
4.38
YA34L-2TC14E2
1 500 kcmil 240 1/4
3/4
1.52
1.27
.23
3.44
W34VT (2) W34VT (2) U34RT (2)
Brown
20
1-7/16
YA34L-2TC38
13/8
1
1.52
1.27
.23
3.88
W34RT (2) U31ART (2)
YA34-2L
13/8
1
1.55
1.27
.23
3.94
YA35-2L
13/8
1-1/8
1.65
1.69
.25
4.64
YA35-2LN
1550 kcmil — 1/2
1-3/4
1.65
1.69
.25
— — U35RT (2)
Yellow
21 1-3/4
YA36-2LN
11/2
1-3/4
1.74
1.38
.27
4.36
U36RT (2)
YA36L-2TC38
1600 kcmil 300 3/8
1
1.73
1.38
.27
4.23
——
U32ART (2)
Green
22 1-3/4
YA37-2L
13/8
1-1/8
1.80
1.39
.27
4.40
YA37-2LN
1650 kcmil — 1/2
1-3/4
1.80
1.39
.27
5.27
— — U37RT (2)
Orange
23
1-15/16
TWO HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
(Continued)
UL Listed 90° C,
600 Volts to 35 kV ◆
45° and 90° angles are available.
Please contact Customer Service to order:
1-800-346-4175
TTT
BB
B
Fig. 1 45° 90°
-- Color code not assigned.
▲See tooling section of this catalog for complete tool and
die listings.
◆For applications greater than 2000 volts consult cable
manufacturer for voltage stress relief instructions.
* Use PUADP-1 adapter with U dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM2conductor sizes listed are the recommendations
for Class 2 conductor.
Note: All dimensions shown are for reference only.
Blue highlighted items are industry standard and most frequently ordered.
C-32
Compression Connections BURNDY®
Copper Compression — Code — Inspection Window

Conductor ▲Installation Tooling
Stud
Stud
Figure Mechanical Hydraulic Wire
Fig *** Hole
Hole Tongue
Dimensions Dieless MD6, OUR840, BCT500HS, Y35, Y39, Y750, Color Die Strip
Catalog Number # AWG MM2Size
Spacing Width
(B) (T) (L) (# of crimps) MD7-34R Y500CTHS Y46*, PAT750 Code Index Length
YA38-2L
13/8
1-1/8
1.84
1.45
.27
4.48
Y644HS (1)
YA38-2LN
11/2
1-3/4
1.81
1.45
.27
5.35
Y81KFT (1)
YA38L-2TC12
1700 kcmil — 1/21-1/21.811.45.274.67
Y81KFTMBH (1)
— — U38RT (2) Pink 400
1-15/16
YA38L-2TC38
13/811.811.45.274.35
PAT81KFT-18V (1)
YA39-2L
13/81-1/81.911.42.274.48
YA39-2LN
11/21-3/41.891.42.275.36
YA39L-2TC12E3
11/21-1/21.891.42.274.92——
U39RT (2)
Black
24
1-15/16
YA39L-2TC38
1 750 kcmil — 3/811.891.42.274.36P39RT (2) **
YA39L-2TC58
15/81-1/21.891.42.275.17Y644HS (1)
YA40-2L
13/81-1/81.981.42.304.63Y81KFT (2)
YA40-2LN
1 800 kcmil 400 1/21-3/41.891.42.305.51
Y81KFTMBH (2)
— — P40RT (3) **
Orange
25
1-15/16
YA40L-2TC38
13/811.951.42.304.51
PAT81KFT-18V (2)
YA41-2L
1 850 kcmil — 3/81-1/82.011.88.314.97— — — Gold 26
1-15/16
YA44-2LN
11/21-3/42.171.65.335.74
YA44-2L
1 1000 kcmil 500 1/21-1/42.191.65.335.24— — P44RT (3) **
White
27
1-15/16
YA44L-2TC12
11/21-1/42.171.65.335.05
TWO HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
(Continued)
UL Listed 90° C,
600 Volts to 35 kV ◆
45° and 90° angles are available.
Please contact Customer Service to order:
1-800-346-4175
TTT
BB
B
Fig. 1 45° 90°
-- Color code not assigned.
▲See tooling section of this catalog for complete tool and
die listings.
◆For applications greater than 2000 volts consult cable
manufacturer for voltage stress relief instructions.
* Use PUADP-1 adapter with U dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, PUADP-1
adapter not required.
*** The MM2conductor sizes listed are the recommendations
for Class 2 conductor.
Note: All dimensions shown are for reference only.
Blue highlighted items are industry standard and most frequently ordered.
C-33
BURNDY®Compression Connections
Copper Compression — Code — Inspection Window