1000398111 Catalog 1

2016-10-06

: Pdf 1000398111-Catalog 1 1000398111-Catalog_1 B5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 72

General Catalog and Product Schedules
Meter Mounting Equipment
www.talonmetering.com
Contents
Product Schedule No. Applications Type(s) Page
402 Residential 135A, 1Ø/3W, OH/UG UAT1 2 – 3
409 Residential 200A, 1Ø/3W, OH UAT3 4 – 5
410 Residential 200A, 1Ø/3W, OH/UG UAT4 6 – 7
411 Residential 200A, 1Ø/3W, UG-sidewire UAS2,8,9 8 – 9
413 Residential 100A, 1Ø/3W, vertical multi-position UAXB 10 – 11
414 Residential 100/150A, 1Ø/3W, multi-position UA12 12 – 13
415 Residential 200A, 1Ø/3W, multi-position UA14 14 – 15
420 Commercial HQ 200A, 1Ø/3W, 4J, OH/UG- lever bypass HQ4U 16 – 17
421 Commercial HQ 200A, 1&3Ø/3W, 5J, OH/UG- lever bypass HQ5U 18 – 19
422 Commercial HQ 200A, 3Ø/4W, 7J, OH/UG- lever bypass HQ7U 20 – 21
423 Commercial HQ 200A, 1&3Ø/3&4W, 4-7J, OH/UG- lever bypass, stud type HQSU 22 – 23
424 Commercial HQ 200A, 3Ø/3W, 5J, OH/UG- lever bypass, neutral disc HQNDU 24 – 25
425 Commercial HQ 200A, 1&3Ø/3&4W, 4-7J, OH/UG- lever bypass, sidewire HQW 26 – 27
426 Commercial HQ 200A, 1&3Ø/3&4W, 5-7J, OH/UG- lever bypass, multi-position HQXW 28 – 29
428 Commercial MQ 200A, 1&3Ø/3&4W, 4-7J, OH/UG- non-clamp lever bypass MQU 30 – 31
430 Commercial HQ 320A, 3/8” Stud, 4-7J, OH/UG- lever bypass, narrow enclosure HQST 32 – 33
431 Commercial HQ 320A, 3/8” Stud, 4-7J, OH/UG- lever bypass, sidewire, narrow enclosure HQSWT 34 – 35
435 Commercial HQ 320A, 1/2” Stud, 4-7J, OH/UG- lever bypass, narrow enclosure HQD 36 – 37
436 Commercial HQ 320A, 1/2” Stud, 4-7J, OH/UG- lever bypass, wide enclosure HQDB/F 38 – 39
437 Commercial HQ 320A, 1/2”& 3/8” Stud, 4-7J, OH/UG- lever bypass, sidewire, wide enclosure HQDSW 40 – 41
440 Resi/Comm K4 400A, 1/2” Stud, 1Ø/3W, OH/UG, non-UL, bolt-in meter K4 42 – 43
443 Resi/Comm K4UT 480A, 1/2” Stud, 1Ø/3W, OH/UG, UL Listed, bolt-in meter K4UT 44 – 45
447 Commercial K7 400A, 1/2” Stud, 3Ø/4W, OH/UG, UL Listed, bolt-in meter K7 46 – 47
448 Commercial K7T 480A, 1/2” Stud, 3Ø/4W, OH/UG, UL Listed, bolt-in meter, std & sidewire K7T & K7SW 48 – 49
418 Residential 200A, 1Ø/3W, multi-position, 1piece lever bypass UA17 50
465 Commercial PTS 20A, 1&3Ø/3&4W, CT rated w/test switch provision, no bypass PTS 51
467 Commercial HQT 20A, 1&3Ø/3&4W, CT rated, lever bypass HQT 52 – 53
469 Commercial HQTS 20A, 1&3Ø/3&4W, CT rated w/test switch provision, lever bypass HQTS 54 – 55
480 Resi/Comm 100/200/320A pedestals & breaker combos UAP/UAB 56 – 57
Meter Combo Breakers 58 – 61
Meter Combinations 58
Circuit Breakers 59
Air Conditioner Disconnects 60
Spa Panels 61
497 Lugs Lugs for devices with studs N/A 62 – 63
498 Accessories Anchor conversion kits, CT conversion kits, hubs, 5th terminals, etc. N/A 64 – 65
500 Applications Electrical service, service type, meter form, socket type N/A 66
Welcome to the Talon utility products catalog
and specification guide. This publication is meant to serve
as a guide to the various Talon meter socket product
families while providing you with a listing of our most
common catalog numbers for each family. Only a small
percentage of our total offering is listed in this catalog so
if you don’t see what you are looking for please keep in
mind that all of our sockets can be customized to fit your
specific needs.
The pages of this catalog will guide you in creating your
own catalog number if there isn’t one listed to fit your
needs. If you need help our network of utility distribution
and sales team will be happy to assist you in determining
the right socket for you. We’ve made every effort to make
this catalog easy to use and understand. A definition for the
headings on the catalog charts is listed to the right. This will
assist you in the selection of your meter socket.
Talon has been the standard for quality and
innovation for meter mounting equipment for over half a
century. The heart of our offering continues to be the HQ
lever bypass socket. The basic design of this socket has not
changed since its original inception in 1956 making this a
solid, time-proven design. We continue to offer the HQ at a
competitive price even when faced with lower cost and
lower quality competition. The bypass blade for every HQ is
rated for 320 amps making every one of our sockets “Heavy
Duty”. Our K base products continue to offer the same
dependability and cost advantages for “extended range”
metering. The residential socket line continues to grow daily
as we continuously add or update our products for an
ever-changing market.
We hope you find this catalog useful and easy to use.
Thank you for your continued support.
Definitions:
Cover Style – Specifies the cover type ring or ringless
Service – UL listed entry points for line side conductors
Terminal – Wide range for line and load lugs
Connector Bypass – Type of bypass installed, if any
Hub Opening – RX = small base, 2.5” max.;
HD = large base 4” max.
Barrel Lock – Barrel lock KO and bracket if installed
5th Jaw Catalog Number – Shows if installed or catalog
number to order
RX = Small hub: 3/4” --2-1/2”
HD = Large hub: 3” -- 4”
a Includes stainless steel latch and hasp.
b Includes cardboard meter opening cover.
c Includes concentric 7/8” and 7/16” barrel lock K.O.
d Cover attaches via 2 brackets with screws behind meter.
e Cover attaches via slider latch behind meter.
Cover Terminal Dimension Hub Barrel Lock 5th Jaw Catalog Number
Style Service Connector Bypass W H D Opening Prov. Kit # Aluminum Steel
Ringless OH/UG #14-2/0 None 8.0 11.7 3.6 RX Opening N/A H659-0121 UAT131-0G UAT111-0G
Ringless OH/UG #14-2/0 None 8.0 11.7 3.6 RX Opening N/A H659-0121 UAT131-0GF UAT111-0GF a
Ringless OH/UG #14-2/0 None 8.0 11.7 3.6 RX Opening 7/16” Factory Installed - UAT111-0MXA
Ringless OH/UG #14-2/0 None 8.0 11.7 3.6 RX Cl. Plate N/A H659-0121 - UAT111-XG
Ringless OH/UG #14-2/0 None 8.0 11.7 3.6 RX Cl. Plate N/A H659-0121 UAT131-XGF UAT111-XGF a
Ringless OH #14-2/0 None 8.0 11.7 3.6 1” Hub Installed N/A H659-0121 - UAT111-AG
Ringless OH #14-2/0 None 8.0 11.7 3.6 1.25” Hub Installed N/A H659-0121 - UAT111-BG
Ringless OH #14-2/0 None 8.0 11.7 3.6 2” Hub Installed N/A H659-0121 - UAT111-DG
Ringless OH/UG #14-2/0 Horn 8.0 11.7 3.6 RX Cl. Plate N/A H659-0121 - UAT111-XPQG
Ringless OH/UG #14-2/0 Horn 8.0 11.7 3.6 RX Opening N/A H659-0121 - UAT111-0PZ b
Ringless OH/UG #14-2/0 Horn 8.0 11.7 3.6 RX Opening 7/16” H659-0121 - UAT111-0PZA
Ringless OH/UG #14-2/0 Horn 8.0 11.7 3.6 RX Opening 7/8” H659-0121 - UAT111-0PGP
Ringless OH/UG #14-2/0 Horn 8.0 11.7 3.6 RX Opening N/A H659-0121 UAT131-0PQG UAT111-0PQG
Ringless OH/UG #14-2/0 Horn 8.0 11.7 3.6 RX Cl. Plate 7/16” or 7/8” Factory Installed - UAT111-XQ c
Ringless OH #14-2/0 Horn 8.0 11.7 3.6 1.25” Hub Installed N/A H659-0121 - UAT111-BPQG
Ringless OH #14-2/0 Horn 8.0 11.7 3.6 1.25” Hub Installed 7/8” Factory Installed - UAT111-BBBU
Ringless OH #14-2/0 Horn 8.0 11.7 3.6 1.50” Hub Installed N/A H659-0121 - UAT111-CP
Ringless UG #14-2/0 Horn 8.0 11.7 3.6 Blank Top N/A H659-0121 - UAT111-PH
Ring OH/UG #14-2/0 None 8.0 11.7 3.6 RX Cl. Plate N/A H659-0121 - UAT121-XGSP d
Ring OH/UG #14-2/0 None 8.0 11.7 3.6 RX Opening N/A H659-0121 - UAT121-0GWR e
Ring OH #14-2/0 None 8.0 11.7 3.6 1.25” Hub Installed N/A H659-0121 - UAT121-BGWR e
Ring UG #14-2/0 None 8.0 11.7 3.6 Blank Top N/A H659-0121 - UAT121-PGWR e
Ring OH/UG #14-2/0 None 8.0 11.7 3.6 RX Opening N/A Factory Installed - UAT121-0BCO e
Ring OH #14-2/0 None 8.0 11.7 3.6 1.25” Hub Installed N/A Factory Installed - UAT121-BBCO e
Ring UG #14-2/0 None 8.0 11.7 3.6 Blank Top N/A Factory Installed - UAT121-PBCO e
Ringless OH #14-2/0 Horn 8.0 11.7 3.6 1.25” Hub Installed 7/8” Factory Installed - UAT111-XMBL
2
KNOCKOUTS (inches):
: 1/4
L: 1/2, 3/4, 1, 1-1/4, 1-1/2
N: 3/4, 1, 1-1/4, 1-1/2, 2
R: 1, 1-1/4, 1-1/2, 2
RX: x2.750 HUB 0P
UAT111-0G
Common Features
J 135A continuous duty rated
J Quad ground on all devices
(2) #14-2/0 and (2) #14-#2
J Lay-in 2/0 max lugs
J Steel or aluminum construction
J Glass filled polyester block construction
J Ring or ringless styles
J Horn or no bypass
TYPE UAT1 135A RESIDENTIAL METER MOUNTING DEVICES
UAT1
Product Schedule 402
1) Select cover style and enclosure material UAT1 _ 1 - _ _ _
2) Select hub style
3) Select options
Consult the factory for other available options such as, but not limited
to insulated 5th terminals, alternate jaw guide configuration, alternate
hasp material and special labeling.
A = 1” Hub Installed
B = 1.25” Hub Installed
C = 1.50” Hub Installed
D = 2” Hub Installed
E = 2.5” Hub Installed
0 = No Hub Installed
X = Cover Plate Installed
P = No Hub Opening
1 = Ringless, Steel
2 = Ring Type, Steel
3 = Ringless, Aluminum
5 = Ringless, Ptd Aluminum
CUSTOMIZED CATALOG NUMBER:
3
Capacity: 135 ampere continuous, 600 volts a.c.
Application: Single phase, 3 wire, self-contained convertible to 5 terminal.
Enclosures: All enclosures shown here are ringless, NEMA Type 3R. All enclosures
are available in either 16 gauge painted steel .063 aluminum in natural
finish. (For painted aluminum enclosures, consult factory.)
Block Assembly: Block assemblies are arc and track resistant thermoset.
Terminals: Terminals are lay-in style, tin-plated, extruded aluminum 6061-T6. Blade and external hex types available.
UL: All sockets are UL listed unless otherwise indicated.
ANSI-C12.7: All sockets meet or exceed ANSI-C12-7 standards.
Hubs: Hubs conform to ANSI standard. 2.5” hub maximum.
Barrel Lock Prov.: Includes bracket and knockout.
GENERAL INFORMATION:
Product Schedule 402
A = Insul. 5th Term 9:00
B = GRND 5th Term 9:00
C = 7/16” B.L. KO
D = 7/16” B.L. KO w/Bracket
E = 7/8” B.L. KO
F = 7/8” B.L. KO w/Bracket
G = Ground Lug
I = Inhibitor
M = 5th Jaw Installed 9:00
N = Gnd Lug &
Insul 5th Term 9:00
P = Horn Bypass
Q = Gnd Lug, Horn Bypass,
Barrel Lock KO
R = Gnd Lug, Horn Bypass,
Insul. 5th Term.
S = Insulating Shield
U = Load Side Taps & Gnd Lug
V = Horn Bypass w/5th Jaw
W = Fixed Hub
Z = Meter Opening Cover
4
Cover Terminal Dimension Hub Barrel Lock 5th Jaw Catalog Number
Style Service Connector Bypass W H D Opening Prov. Kit # Aluminum Steel
Ringless OH #6-350 kcmil None 8.0 14.8 4.5 RX Opening N/A H659-0121 - UAT314-0G g
Ringless OH #6-350 kcmil None 8.0 14.8 4.5 1.25” Hub Installed N/A H659-0121 - UAT314-BG g
Ringless OH #6-350 kcmil None 8.0 14.8 4.5 RX Opening N/A H659-0121 UAT337-0G UAT317-0G
Ringless OH #6-350 kcmil None 8.0 14.8 4.5 RX Opening N/A H659-0121 UAT337-0GFa UAT317-0GF a
Ringless OH #6-350 kcmil None 8.0 14.8 4.5 2” Hub Installed N/A H659-0121 UAT337-DG UAT317-DG
Ringless OH #6-350 kcmil None 8.0 14.8 4.5 2.5” Hub Installed N/A H659-0121 - UAT317-EG
Ringless OH #6-350 kcmil None 8.0 14.8 4.5 RX Opening 7/16” Factory Installed - UAT317-0MXA
Ringless OH #6-350 kcmil Horn 8.0 14.8 4.5 RX Opening 7/16” or 7/8” Factory Installed - UAT317-0Q c
Ringless OH #6-350 kcmil Horn 8.0 14.8 4.5 RX Opening 7/8” Factory Installed - UAT317-0FP
Ringless OH #6-350 kcmil Horn 8.0 14.8 4.5 RX Opening 7/8” H659-0121 - UAT317-0PGP
Ringless OH #6-350 kcmil Horn 8.0 14.8 4.5 RX Opening N/A H659-0121 UAT337-0PQG UAT317-0PQG
Ringless OH #6-350 kcmil Horn 8.0 14.8 4.5 RX Opening 7/16” H659-0121 - UAT317-0PZA
Ringless OH #6-350 kcmil Horn 8.0 14.8 4.5 2” Hub Installed N/A Factory Installed - UAT317-DVZ b
Ringless OH #6-350 kcmil Horn 8.0 14.8 4.5 2” Hub Installed 7/8” Factory Installed - UAT317-DBBU
Ringless OH #6-350 kcmil Horn 8.0 14.8 4.5 2” Hub Installed N/A H659-0121 - UAT317-DPQG
Ring OH #6-350 kcmil None 8.0 14.8 4.5 RX Opening N/A H659-0121 - UAT327-0G e
Ring OH #6-350 kcmil None 8.0 14.8 4.5 RX Opening N/A Factory Installed - UAT327-0B e
Ring OH #6-350 kcmil None 8.0 14.8 4.5 RX Opening N/A H659-0121 - UAT327-0GSP d
Ring OH #6-350 kcmil None 8.0 14.8 4.5 RX Opening N/A H659-0121 - UAT327-0GWR e
Ring OH #6-350 kcmil None 8.0 14.8 4.5 RX Opening N/A Factory Installed - UAT327-0MCO e
a Includes stainless steel latch and hasp.
b Includes cardboard meter opening cover.
c Includes concentric 7/8” and 7/16” barrel lock K.O.
d Cover attaches via 2 brackets with screws behind meter.
e Cover attaches via slider latch behind meter.
f Catalog numbers listed include KO and bracket for barrel lock.
g De-rated to160 amps continuous.
KNOCKOUTS (inches):
: 1/4
A: 1/2
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
RX: x2.750 HUB 0P
TYPE UAT3 200A RESIDENTIAL METER MOUNTING DEVICES
Common Features
J OH only construction
J 200A continuous duty rated
J 250A max rated
J Quad ground on all devices
(2) #6-350 kcmil and (2) #2-14
J Lay-in 350 kcmil max lugs
J Steel or aluminum construction
J Glass-filled polyester block construction
J Ring or ringless style
J Horn bypass available
UAT317-0Q
UAT3
Product Schedule 409
5
1) Select cover style and enclosure material UAT3 _ _ - _ _ _
2) Select hub style
3) Select options
Consult the factory for other available options such as, but not limited
to insulated 5th terminals, alternate jaw guide configuration, alternate
hasp material and special labeling.
Capacity: 200 ampere continuous, 600 volts a.c.
Application: Single phase, 3 wire, self-contained convertible to 5 terminal.
Enclosures: All enclosures shown here are ringless, NEMA Type 3R. All enclosures
are available in either 16 gauge painted steel .063 aluminum in natural
finish. (For painted aluminum enclosures, consult factory.)
Block Assembly: Block assemblies are arc and track resistant thermoset.
Terminals: Terminals are lay-in style, tin-plated, extruded aluminum 6061-T6.
UL: All sockets are UL listed unless otherwise indicated.
ANSI-C12.7: All sockets meet or exceed ANSI-C12-7 standards.
Stud-Type: Optional stud-type connectors are available, consult factory.
Hubs: Hubs conform to ANSI standard. 2.5” hub maximum.
Barrel Lock Prov.: Includes bracket and knockout.
GENERAL INFORMATION:
4 = 160 Amp continuous rated
7 = 200 Amp continuous rated
A = Insul. 5th Term 9:00
B = GRND 5th Term 9:00
C = 7/16” B.L. KO
D = 7/16” B.L. KO w/Bracket
E = 7/8” B.L. KO
F = 7/8” B.L. KO w/Bracket
G = Ground Lug
I = Inhibitor
M = 5th Jaw Installed 9:00
N = Gnd Lug &
Insul 5th Term 9:00
P = Horn Bypass
Q = Gnd Lug, Horn Bypass,
Barrel Lock KO
R = Gnd Lug, Horn Bypass,
Insul. 5th Term.
S = Insulating Shield
U = Load Side Taps & Gnd Lug
V = Horn Bypass w/5th Jaw
W = Fixed Hub
Z = Meter Opening Cover
A = 1” Hub Installed
B = 1.25” Hub Installed
C = 1.50” Hub Installed
D = 2” Hub Installed
E = 2.5” Hub Installed
0 = No Hub Installed
X = Cover Plate Installed
P = No Hub Opening
1 = Ringless, Steel
2 = Ring Type, Steel
3 = Ringless, Aluminum
5 = Ringless, Ptd Aluminum
CUSTOMIZED CATALOG NUMBER:
Product Schedule 409
6
UAT417-XPQG
KNOCKOUTS (inches):
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
AB: 1/4, 1/2, 7/8
RX: x2.750 HUB 0P
AC: 1/4, 1/2
AD: 1-1/4, 1-1/2, 2, 2-1/2, 3
TYPE UAT4 200A RESIDENTIAL METER MOUNTING DEVICES
a Includes stainless steel latch and hasp.
b Includes cardboard meter opening cover.
c Includes concentric 7/8” and 7/16” barrel lock K.O.
d Cover attaches via 2 brackets with screws behind meter.
e Cover attaches via slider latch behind meter.
f Catalog numbers listed include KO and bracket for barrel lock.
g De-rated to160 amps continuous.
h De-rated to125 amps continuous.
i KO’s match UAT4.
Cover Terminal Dimension Hub Barrel Lock 5th Jaw Catalog Number
Style Service Connector Bypass W H D Opening Prov. Kit # Aluminum Steel
Ringless OH/UG #14-2/0 None 11.0 14.8 4.5 RX Cl. Plate N/A H659-0121 - UAT411-XG h
Ringless OH/UG #14-2/0 None 11.0 14.8 4.5 RX Cl. Plate N/A H659-0121 - UAT411-XVZ h
Ringless OH/UG #6-350 kcmil None 11.0 14.8 4.5 RX Opening N/A H659-0121 UAT434-0G UAT414-0G g
Ringless UG #6-350 kcmil None 11.0 14.8 4.5 Blank Top N/A H659-0121 UAT434-PG -
Ringless OH/UG #6-350 kcmil None 11.0 14.8 4.5 RX Opening N/A H659-0121 UAT437-0G UAT417-0G
Ringless OH/UG #6-350 kcmil None 11.0 14.8 4.5 RX Opening N/A H659-0121 UAT437-0GF UAT417-0GF a
Ringless OH #6-350 kcmil None 11.0 14.8 4.5 2” Hub Installed N/A H659-0121 - UAT417-DG
Ringless OH #6-350 kcmil None 11.0 14.8 4.5 2.5” Hub Installed N/A H659-0121 - UAT417-EG
Ringless UG #6-350 kcmil None 11.0 14.8 4.5 Blank Top N/A H659-0121 UAT437-PG UAT417-PG
Ringless UG #6-350 kcmil None 11.0 14.8 4.5 Blank Top N/A H659-0121 UAT437-PGF UAT417-PGF a
Ringless OH/UG #6-350 kcmil None 11.0 14.8 4.5 RX Cl. Plate N/A H659-0121 UAT437-XG UAT417-XG
Ringless OH/UG #6-350 kcmil None 11.0 14.8 4.5 RX Cl. Plate N/A H659-0121 UAT437-XGF UAT417-XGF a
Ringless OH/UG #6-350 kcmil None 11.0 14.8 4.5 RX Cl. Plate N/A H659-0121 UAT457-XG -
Ringless OH/UG #6-350 kcmil None 11.0 14.8 4.5 RX Cl. Plate 7/16” Factory Installed - UAT417-X0XAf
Ringless UG #6-350 kcmil None 11.0 14.8 4.5 Blank Top 7/16” Factory Installed - UAT417-P0XAf
Ringless OH/UG #6-350 kcmil Horn 11.0 14.8 4.5 RX Opening N/A H659-0121 - UAT417-0P
Ringless OH/UG #6-350 kcmil Horn 11.0 14.8 4.5 RX Opening N/A H659-0121 - UAT417-0PZ
Ringless OH/UG #6-350 kcmil Horn 11.0 14.8 4.5 RX Opening N/A H659-0121 - UAT417-0PQG
Ringless OH/UG #6-350 kcmil Horn 11.0 14.8 4.5 RX Cl. Plate 7/16” or 7/8” Factory Installed - UAT417-XQ cf
Ringless OH/UG #6-350 kcmil Horn 11.0 14.8 4.5 RX Cl. Plate 7/8” Factory Installed - UAT417-XFP f
Ringless OH/UG #6-350 kcmil Horn 11.0 14.8 4.5 RX Cl. Plate N/A Factory Installed - UAT417-XVZ b
Ringless OH/UG #6-350 kcmil Horn 11.0 14.8 4.5 RX Cl. Plate 7/8” Factory Installed - UAT417-XMBL
Ringless OH/UG #6-350 kcmil Horn 11.0 14.8 4.5 RX Cl. Plate N/A H659-0121 - UAT417-XPQG
Ringless UG #6-350 kcmil Horn 11.0 14.8 4.5 Blank Top N/A H659-0121 - UAT417-PPQG
Ring OH/UG #6-350 kcmil None 11.0 14.8 4.5 RX Opening N/A H659-0121 - UAT427-0G e
Ring UG #6-350 kcmil None 11.0 14.8 4.5 Blank Top N/A Factory Installed - UAT427-PMCO
Ring OH/UG #6-350 kcmil None 11.0 14.8 4.5 RX Cl. Plate N/A H659-0121 - UAT427-XG e
Ring OH/UG #6-350 kcmil None 11.0 14.8 4.5 RX Cl. Plate N/A H659-0121 - UAT427-XGSP d
Ring OH/UG #6-350 kcmil None 11.0 14.8 4.5 RX Cl. Plate N/A Factory Installed - UAT427-XMWRe
Ring UG #6-350 kcmil None 11.0 14.8 4.5 Blank Top N/A Factory Installed - UAT427-PBe
Ringless OH/UG 3/8”-24 Stud None 11.0 22.0 4.5 RX Cl. Plate N/A H659-0121 - UAT619-XGi
Ringless OH/UG #6-350 kcmil None 13.0 13.8 5.2 RX Cl. Plate 7/16” H659-0121 - UAT817-XGD
UAT4
UAT6
Common Features
J OH/UG construction
J 200A continuous duty rated
J 250A max rated
J Quad ground on all devices
(2) #6-350 kcmil and (2) #2-14
J Lay-in 350 kcmil max lugs
J Steel or aluminum construction
J Glass filled polyester block construction
J Ring or ringless style
J Horn bypass available
Product Schedule 410
UAT8
7
1) Select cover style and enclosure material UAT4 _ _ - _ _ _
2) Select hub style
3) Select options
Consult the factory for other available options such as,
but not limited to insulated 5th terminals, alternate jaw
guide configuration, alternate hasp material and special labeling.
1 = Ringless, Steel
2 = Ring Type, Steel
3 = Ringless, Aluminum
5 = Ringless, Ptd Aluminum
6 = 11 x 22 enclosure, RL Steel
8 = 13 x 14 enclosure, RL Steel
1 = 125 Amp continuous rated
4 = 160 Amp continuous rated
7 = 200 Amp continuous rated
Capacity: 200 ampere continuous, 600 volts a.c.
Application: Single phase, 3 wire, self-contained convertible to 5 terminal.
Enclosures: All enclosures shown here are ringless, NEMA Type 3R. All enclosures are available in either 16 gauge painted steel .063
aluminum in natural finish. (For painted aluminum enclosures, consult factory.)
Block Assembly: Block assemblies are arc and track resistant thermoset.
Terminals: Lay-in style, tin-plated, extruded aluminum 6061-T6.
UL: All sockets are UL listed unless otherwise indicated.
ANSI-C12.7: All sockets meet or exceed ANSI-C12-7 standards.
Stud-Type: Optional stud-type connectors are available, consult factory.
Hubs: Hubs conform to ANSI standard. 2.5” hub maximum.
Barrel Lock Prov.: Includes bracket and knockout.
GENERAL INFORMATION:
CUSTOMIZED CATALOG NUMBER:
A = 1” Hub Installed
B = 1.25” Hub Installed
C = 1.50” Hub Installed
D = 2” Hub Installed
E = 2.5” Hub Installed
0 = No Hub Installed
X = Cover Plate Installed
P = No Hub Opening
Product Schedule 410
A = Insul. 5th Term 9:00
B = GRND 5th Term 9:00
C = 7/16” B.L. KO
D = 7/16” B.L. KO w/Bracket
E = 7/8” B.L. KO
F = 7/8” B.L. KO w/Bracket
G = Ground Lug
I = Inhibitor
M = 5th Jaw Installed 9:00
N = Gnd Lug &
Insul 5th Term 9:00
P = Horn Bypass
Q = Gnd Lug, Horn Bypass,
Barrel Lock KO
R = Gnd Lug, Horn Bypass,
Insul. 5th Term.
S = Insulating Shield
U = Load Side Taps & Gnd Lug
V = Horn Bypass w/5th Jaw
W = Fixed Hub
Z = Meter Opening Cover
8
200A TYPE UAS2/UAS8/UAS9 RESIDENTIAL METER MOUNTING DEVICES
a UL listed for underground use. OH service does not meet UL wire bend requirements.
b UL listed for overhead and underground use.
UAS817-PPZA
KNOCKOUTS (inches):
B: 1/2, 3/4
N: 3/4, 1, 1-1/4, 1-1/2
X: 1-1/4, 1-1/2, 2, 2-1/2
AC: 1/4, 1/2
AD: 1-1/4, 1-1/2, 2, 2-1/2, 3
EE: 2, 2-1/2, 3
RX: x2.75
c Includes barrel lock bracket.
d UG device with interior moved up.
UAS2 UAS8 UAS9
Common Features
J 200A continuous duty rated
J 250A max rated
J Ground lug on all devices
J Lay-in 350 kcmil lugs or stud connection
J Steel or aluminum construction
J Glass filled polyester block construction
J Left or right hand bus
J Overhead and underground capabilities
Product Schedule 411
Cover Terminal Connector Dimensions (in.) Hub Barrel Lock 5th Jaw Feed Catalog Number
Style Service Line Load Bypass W H D Opening KO Prov.(6) Kit Number Location Aluminum Steel
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 13.0 14.0 5.1 RX Cl. Plate N/A H659-0121 Left UAS837-XG UAS877-XG a
Ringless OH/UG 3/8”- 24 stud #6-350 kcmil None 13.0 14.0 5.1 RX Cl. Plate N/A H659-0121 Left - UAS878-XG a
Ringless OH/UG #6-350 kcmil #6-350 kcmil Horn 13.0 14.0 5.1 RX Cl. Plate N/A H659-0121 Left - UAS877-XPG a
Ringless UG #6-350 kcmil #6-350 kcmil None 13.0 14.0 5.1 Blank Top N/A H659-0121 Left UAS837-PG UAS877-PG
Ringless UG #6-350 kcmil #6-350 kcmil Horn 13.0 14.0 5.1 Blank Top 7/16” H659-0121 Left - UAS877-PPZA c
Ringless UG #6-350 kcmil #6-350 kcmil Horn 13.0 14.0 5.1 Blank Top 7/8” H659-0121 Left - UAS877-PPGP c
Ringless UG #6-350 kcmil #6-350 kcmil None 13.0 14.0 5.1 Blank Top N/A H659-0121 Right - UAS817-PG
Ringless UG #6-350 kcmil #6-350 kcmil Horn 13.0 14.0 5.1 Blank Top 7/8” Factory Inst. Right - UAS817-PFP c
Ringless UG #6-350 kcmil #6-350 kcmil Horn 13.0 14.0 5.1 Blank Top 7/16” H659-0121 Right - UAS817-PPZA c
Ringless UG #6-350 kcmil #6-350 kcmil Horn 13.0 14.0 5.1 Blank Top 7/8” H659-0121 Right - UAS817-PPGP c
Ringless UG #6-350 kcmil #6-350 kcmil None 13.0 14.0 5.1 Blank Top 7/16” Factory Inst. Right - UAS817-P0XA c
Ringless UG 3/8”- 24 stud #6-350 kcmil None 13.0 14.0 5.1 Blank Top 7/8” H659-0121 Right - UAS818-PGNM
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 13.0 18.0 5.1 RX Opening N/A H659-0121 Right UAS937-0G UAS917-0G b
Ringless OH/UG #6-350 kcmil 3/8”- 24 stud None 13.0 18.0 5.1 RX Opening N/A H659-0121 Right - UAS917-0GLE b
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 13.0 18.0 5.1 RX Opening N/A H659-0121 Right - UAS917-0GSK b
Ringless UG #6-350 kcmil #6-350 kcmil None 13.0 18.0 5.1 Blank Top N/A H659-0121 Right - UAS917-PG
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 13.0 18.0 5.1 RX Cl. Plate N/A H659-0121 Right - UAS917-XG b
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 13.0 18.0 5.1 RX Cl. Plate N/A H659-0121 Left - UAS977-XG b
Ringless UG #6-350 kcmil #6-350 kcmil None 13.0 19.0 5.1 Blank Top N/A H659-0121 Left UAS237-PG UAS277-PG d
Ringless UG 3/8”-24 stud 3/8”- 24 stud None 13.0 19.0 5.1 Blank Top N/A H659-0121 Left - UAS278-PG d
9
A = 1” Hub Installed
B = 1.25” Hub Installed
C = 1.50” Hub Installed
D = 2” Hub Installed
E = 2.5” Hub Installed
0 = No Hub Installed
X = Cover Plate Installed
P = No Hub Opening
1 = Right hand feed, ST
3 = Left hand feed, AL
5 = Right hand feed, AL
7 = Left hand feed, ST
7 = 200 amp w/lugs
8 = 200 amp w/studs
Capacity: 200 ampere continuous.
Application: Single phase, 3 wire, self-contained convertible to 5 terminal.
Enclosures: All enclosures shown here are ringless, NEMA Type 3R. All enclosures
are available in 16 gauge painted steel finish. (For aluminum enclosures, consult factory.)
Block Assembly: Block assemblies are arc and track resistant thermoset.
Terminals: Terminals are lay-in style, tin-plated, extruded aluminum 6061-T6.
UL: All sockets are UL listed. Underground feed only for Type AS-2 and AS-8.
ANSI-C12.7: All sockets meet or exceed ANSI-C12-7 standards.
Hubs: Hubs conform to ANSI standard. 2.5” hub maximum.
Barrel Lock Prov.: Includes bracket and knockout.
GENERAL INFORMATION:
2 = 13” x 19” enclosure
8 = 13” x 14” enclosure
9 = 13” x 17” enclosure
CUSTOMIZED CATALOG NUMBER:
1) Select cover style and enclosure material UAS _ _ _ - _ _ _
2) Select hub style
3) Select options
Consult the factory for other available options such as, but not limited to insulated
5th terminals, alternate jaw guide configuration, alternate hasp material and special labeling.
Product Schedule 411
A = Insul. 5th Term 9:00
B = GRND 5th Term 9:00
C = 7/16” B.L. KO
D = 7/16” B.L. KO w/Bracket
E = 7/8” B.L. KO
F = 7/8” B.L. KO w/Bracket
G = Ground Lug
I = Inhibitor
M = 5th Jaw Installed 9:00
N = Gnd Lug &
Insul 5th Term 9:00
P = Horn Bypass
Q = Gnd Lug, Horn Bypass,
Barrel Lock KO
R = Gnd Lug, Horn Bypass,
Insul. 5th Term.
S = Insulating Shield
U = Load Side Taps & Gnd Lug
V = Horn Bypass w/5th Jaw
W = Fixed Hub
Z = Meter Opening Cover
10
KNOCKOUTS (inches):
L: 1/2, 3/4, 1, 1-1/4, 1-1/2
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
AC: 1/4, 1/2
RX: x2.750 HUB 0P
TYPE UAXB VERTICAL MULTI-POSITION RESIDENTIAL/COMMERCIAL METER MOUNTING DEVICES
Cover Terminal Connector Dimensions (inches) Hub Barrel Lock 5th Jaw No. of Cont. Catalog
Style Service Line Load Bypass W H D Opening KO Prov. Kit No. Pos. Amps/Pos. Number
Ringless OH #8-350 kcmil #8-20 None 8.0 25.6 4.4 RX Cl. Plate 7/16” H659-0121 2 125 UA2B11-XG
Ringless OH #8-350 kcmil #8-2/0 Horn 8.0 25.6 4.4 RX Opening 7/16” H659-0121 2 125 UA2B11-0PZA
Ringless OH #8-350 kcmil #8-2/0 Horn 8.0 35.9 4.4 RX Opening 7/16” H659-0121 3 125 UA3B11-0PZA
Ring Type OH #8-350 kcmil #8-2/0 None 8.0 25.6 4.4 RX Opening 7/16” Installed 2 125 UA2B21-0MCO
Ring Type OH #8-350 kcmil #8-2/0 None 8.0 35.9 4.4 RX Opening 7/16” Installed 3 125 UA3B21-0MCO
Ringless OH #8-350 kcmil #8-2/0 Horn 8.0 25.6 4.4 RX Opening 7/8” H659-0121 2 125 UA2B11-0PGP
Ringless OH #8-350 kcmil #8-2/0 Horn 8.0 35.9 4.4 RX Opening 7/8” H659-0121 3 125 UA3B11-0PGP
Common Features
J 100A continuous duty rated
J 125A max. rated
J Ground lug on all devices
J Lay-in 350 kcmil lugs or stud connections
J Steel or aluminum construction
J Glass filled polyester block construction
J Left or right hand bus
J Overhead and underground capabilities
Product Schedule 413
11
Capacity: 200 ampere continuous, 600 volts a.c.
Application: 1 phase, 3 wire wye or 3 wire delta services using self-contained Class 100 or Class 200 meters.
Enclosures: Constructed of 16 gauge galvannealed steel with polyester powder finish, suitable for indoor or outdoor installation. Also
available in aluminum and different sizes upon request. All boxes have ringless covers. All enclosures are NEMA type 3R.
Block Assembly: Glass fiber reinforced polyester mounted on metal baseplate. High strength, arc and track resistant.
Safety Shield: Track resistant polycarbonate insulating safety shield provides protection from accidental shorts and shocks.
Terminals: Lay-in type with dome point screw. Conservatively rated at 200 amperes, terminals will accommodate conductors from #8
to 350 MCM copper or aluminum.
Hubs: Single, removable, gasketless hub; cover plate, or no hub. Hubs and cover plate are interchangeable.
UL: These mounting devices are listed by UL for use on continuous loads up to 200 amperes and 600 volts.
ANSI-C12.7: All sockets meet or exceed ANSI-C12-7 standards.
GENERAL INFORMATION:
A = 1” Hub Installed
B = 1.25” Hub Installed
C = 1.50” Hub Installed
D = 2” Hub Installed
E = 2.5” Hub Installed
0 = No Hub Installed
X = Cover Plate Installed
P = No Hub Opening
1 = Ringless, Steel
2 = Ring Style, Steel
2 = 2 Gang
3 = 3 Gang
1) Select cover style, enclosure material, UA _ _ _ _ - _ _ _
and number of positions
2) Select hub style
3) Select options
Consult the factory for other available options such
as, but not limited to insulated 5th terminals, alternate jaw
guide configuration, alternate hasp material and special labeling.
B = Vertical Design
CUSTOMIZED CATALOG NUMBER:
1 = 125 amp/position
Product Schedule 413
A = Insul. 5th Term 9:00
B = GRND 5th Term 9:00
C = 7/16” B.L. KO
D = 7/16” B.L. KO w/Bracket
E = 7/8” B.L. KO
F = 7/8” B.L. KO w/Bracket
G = Ground Lug
I = Inhibitor
M = 5th Jaw Installed 9:00
N = Gnd Lug &
Insul 5th Term 9:00
P = Horn Bypass
Q = Gnd Lug, Horn Bypass,
Barrel Lock KO
R = Gnd Lug, Horn Bypass,
Insul. 5th Term.
S = Insulating Shield
U = Load Side Taps & Gnd Lug
V = Horn Bypass w/5th Jaw
W = Fixed Hub
Z = Meter Opening Cover
12
UA2311-XBBU
100/150A/POS MULTI-POSITION RESIDENTIAL METER MOUNTING DEVICES TYPE A12
Common Features
J Ground lug on all devices
J Lay-in 350 kcmil lugs or stud connection
J Steel or aluminum construction
J Glass filled polyester block construction
J Left- or right-hand bus
J Overhead and underground capabilities
Cover Terminal Connector Dimension (inches) Hub Barrel Lock 5th Jaw No.of Cont. Catalog Number
Style Service Line Load Bypass W H D Opening KO Prov (6) Kit No. Pos. Amps/Pos.Aluminum Steel
Ringless OH/UG #6-350 kcmil #14-2/0 None 24.0 12.0 4.5 RX Opening N/A H659-0121 2 100 - A2311-0PZ a
Ringless OH/UG #6-350 kcmil #14-2/0 None 24.0 12.0 4.5 RX Opening N/A H659-0121 2 100 UA2331-0G UA2311-0G
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 24.0 12.0 4.5 RX Opening N/A H659-0121 2 100 - UA2311-0P
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 24.0 12.0 4.5 RX Opening 7/16” H659-0121 2 100 - UA2311-0PZA c
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 24.0 12.0 4.5 RX Opening 7/8” H659-0121 2 100 - UA2311-0PGP c
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 24.0 12.0 4.5 RX Opening N/A H659-0121 2 100 - UA2311-0PQG b
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 24.0 12.0 4.5 RX Cl. Plate 7/8” Factory Inst. 2 100 - UA2311-XBBU c
Ringless OH/UG #6-350 kcmil #6-350 kcmil Horn 24.2 12.0 5.2 HD Opening N/A H659-0121 2 160 - UA2533-YG
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 32.0 12.0 4.5 RX Opening N/A H659-0121 3 100 - A3311-0PZ a
Ringless OH/UG #6-350 kcmil #14-2/0 None 32.0 12.0 4.5 RX Opening N/A 659-0121 3 100 UA3331-0G UA3311-0G
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 32.0 12.0 4.5 RX Opening N/A H659-0121 3 100 - UA3311-0PZ
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 32.0 12.0 4.5 RX Opening 7/16” H659-0121 3 100 - UA3311-0PZA c
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 32.0 12.0 4.5 RX Opening 7/8” H659-0121 3 100 - UA3311-0PGP c
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 32.0 12.0 4.5 RX Opening N/A H659-0121 3 100 - UA3311-0PQG b
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 32.0 12.0 4.5 RX Cl. Plate 7/8” Factory Inst. 3 100 UA3311-XBBU c
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 40.0 12.0 4.5 RX Opening N/A H659-0121 4 100 - A4311-0PZ a
Ringless OH/UG #6-350 kcmil #14-2/0 None 40.0 12.0 4.5 RX Opening N/A H659-0121 4 100 UA4331-0G UA4311-0G
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 40.0 12.0 4.5 RX Opening N/A H659-0121 4 100 - UA4311-0PZ
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 40.0 12.0 4.5 RX Opening 7/16” H659-0121 4 100 - UA4311-0PZA c
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 40.0 12.0 4.5 RX Opening 7/8” H659-0121 4 100 - UA4311-0PGP c
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 40.0 12.0 4.5 RX Opening N/A H659-0121 4 100 - UA4311-0PQG b
Ringless OH/UG #6-350 kcmil #14-2/0 Horn 40.0 12.0 4.5 RX Cl. Plate 7/8” Factory Inst. 4 100 - UA4311-XBBU c
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 24.0 12.0 4.5 RX Opening N/A H659-0121 2 160 UA2333-0G UA2313-0G
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 24.0 12.0 4.5 RX Cl. Plate N/A H659-0121 2 160 - UA2313-XG
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 32.0 12.0 4.5 RX Opening N/A H659-0121 3 160 UA3333-0G UA3313-0G
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 32.0 12.0 4.5 RX Cl. Plate N/A H659-0121 3 160 - UA3313-XG
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 40.0 12.0 4.5 RX Opening N/A H659-0121 4 160 UA4333-0G UA4313-0G
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 40.0 12.0 4.5 RX Cl. Plate N/A H659-0121 4 160 - UA4313-XG
Ring OH/UG #6-350 kcmil #14-2/0 None 24.0 12.0 4.5 RX Opening N/A H659-0121 2 100 - UA2321-0G
Ring OH/UG #6-350 kcmil #14-2/0 None 32.0 12.0 4.5 RX Opening N/A H659-0121 3 100 - UA3321-0G
Ring OH/UG #6-350 kcmil #14-2/0 None 40.0 18.1 5.4 RX Cl. Plate N/A H659-0121 4 100 - UA4321-0G
Cover Terminal Connector Dimension (inches) Hub Barrel Lock 5th Jaw No.of Cont. Catalog Number
Style Service Line Load Bypass W H D Opening KO Prov (6) Kit No. Pos. Amps/Pos.Aluminum Steel
Ringless OH/UG #6-250 kcmil #6-2/0 None 24.2 18.1 5.4 RX Cl. Plate N/A H659-0121 2 100 - UA2411-XG
Ringless OH/UG #6-250 kcmil #6-2/0 None 34.4 18.1 5.4 RX Cl. Plate N/A H659-0121 3 100 - UA3411-XG
Ringless OH/UG #6-250 kcmil #6-2/0 None 40.5 18.1 5.4 RX Cl. Plate N/A H659-0121 4 100 - UA4411-XG
Ringless OH/UG #6-250 kcmil #6-2/0 None 48.6 18.1 5.4 RX Cl. Plate N/A H659-0121 5 100 - UA5411-XG
Ringless OH/UG #6-350 kcmil #6-2/0 None 56.8 18.1 5.4 RX Cl. Plate N/A H659-0121 6 100 - UA6411-XG
Ringless OH #6-250 kcmil #6-2/0 None 24.2 18.1 5.4 2” Hub Inst. N/A H659-0121 2 100 - UA2411-DG
Ringless OH #6-250 kcmil #6-2/0 None 34.4 18.1 5.4 2” Hub Inst. N/A H659-0121 3 100 - UA3411-DG
Ringless OH #6-250 kcmil #6-2/0 None 40.5 18.1 5.4 2” Hub Inst. N/A H659-0121 4 100 - UA4411-DG
Ringless OH #6-250 kcmil #6-2/0 None 48.6 18.1 5.4 2” Hub Inst. N/A H659-0121 5 100 - UA5411-DG
Ringless OH #6-350 kcmil #6-2/0 None 56.8 18.1 5.4 2” Hub Inst. N/A H659-0121 6 100 - UA6411-DG
a Non-UL listed.
Product Schedule 414
Note: End feed units listed below
b Two (2) ground lugs/position included. c Includes barrel lock bracket.
13
Capacity: 100 and 150 amps continuous.
Application: Single phase, 3 wire, self-contained convertible to 5 terminal.
Enclosures: All enclosures shown here are ringless, NEMA Type 3R. All enclosures are available in 16 gauge painted steel finish.
(For aluminum enclosures, consult factory.)
Block Assembly: Block assemblies are arc and track resistant thermoset.
Terminals: Terminals are lay-in style, tin-plated, extruded aluminum 6061-T6.
UL: All sockets are UL listed.
ANSI-C12.7: All sockets meet or exceed ANSI-C12-7 standards.
Hubs: Hubs conform to ANSI standard. 2.5” hub maximum.
Barrel Lock Prov.: Includes bracket and knockout.
GENERAL INFORMATION:
1) Select cover style, enclosure material UA _ _ _ _ - _ _ _
and number of positions.
2) Select hub style
3) Select options
Consult the factory for other available options such as, but not limited to insulated
5th terminals, alternate jaw guide configuration, alternate hasp material and special labeling.
A = 1” Hub Installed
B = 1.25” Hub Installed
C = 1.50” Hub Installed
D = 2” Hub Installed
E = 2.5” Hub Installed
0 = No Hub Installed
X = Cover Plate Installed
P = No Hub Opening
Y = Large Opening
CUSTOMIZED CATALOG NUMBER:
3 = Center Feed
4 = End Feed
5 = Center feed,
LG Hub Open
1 = Ringless, Steel
2 = Ring Style, Steel
3 = Ringless, Al
1 = 100 Amp/position
3 = 160 Amp/position
2 = 2 Gang
3 = 3 Gang
4 = 4 Gang
5 = 5 Gang
6 = 6 Gang
KNOCKOUT DIAGRAMS
KNOCKOUTS (inches):
L: 1/2, 3/4, 1, 1-1/4, 1-1/2
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
AC: 1/4, 1/2
RX: x2.750 HUB 0P
Product Schedule 414
A = Insul. 5th Term 9:00
B = GRND 5th Term 9:00
C = 7/16” B.L. KO
D = 7/16” B.L. KO w/Bracket
E = 7/8” B.L. KO
F = 7/8” B.L. KO w/Bracket
G = Ground Lug
I = Inhibitor
M = 5th Jaw Installed 9:00
N = Gnd Lug &
Insul 5th Term 9:00
P = Horn Bypass
Q = Gnd Lug, Horn Bypass,
Barrel Lock KO
R = Gnd Lug, Horn Bypass,
Insul. 5th Term.
S = Insulating Shield
U = Load Side Taps & Gnd Lug
V = Horn Bypass w/5th Jaw
W = Fixed Hub
Z = Meter Opening Cover
14
Cont.
Cover Terminal Connector Dimensions (in.) Hub 5th Jaw No.of Amps Catalog Number
Style Service Line Load Bypass W H D Opening Kit No. Pos. Pos. Steel Aluminum
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 24.0 14.5 5.1 RX Opening H659-0121 2 200 UA2716-0G a -
Ringless OH/UG #6-350 kcmil #6-350 kcmil Horn 24.0 14.5 5.1 RX Opening H659-0121 2 200 UA2716-0P -
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 24.0 14.5 5.1 RX Cl. Plate H659-0121 2 200 UA2716-XG a -
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 24.0 14.5 5.1 HD Opening H659-0121 2 200 UA2716-YG a UA2736-YG a
Ringless OH/UG #6-350 kcmil #6-350 kcmil None 24.0 14.5 5.1 HD Cl. Plate H659-0121 2 200 UA2716-ZGF ac UA2736-ZGF ac
Ringless OH/UG 1/0-600 kcmil #6-350 kcmil None 24.0 14.5 5.1 HD Opening H659-0121 2 200 UA2717-YG UA2737-YG
Ringless OH/UG 1/0-600 kcmil #6-350 kcmil Horn 24.0 14.5 5.1 HD Opening H659-0121 2 200 UA2717-YPZ -
Ringless OH/UG 1/0-600 kcmil #6-350 kcmil Horn 24.0 14.5 5.1 HD Opening H659-0121 2 200 UA2717-YPQG b -
Ringless OH/UG 1/0-600 kcmil #6-350 kcmil Horn 24.0 14.5 5.1 HD Opening H659-0121 2 200 UA2717-YPGPe -
Ringless OH/UG 1/0-600 kcmil #6-350 kcmil Horn 24.0 14.5 5.1 HD Opening H659-0121 2 200 UA2717-YPRG -
Ringless OH/UG 1/0-600 kcmil #6-350 kcmil Horn 24.0 14.5 5.1 HD Opening H659-0121 2 200 UA2717-YPZAf -
Ringless OH/UG 3/8-24 Stud #6-350 kcmil None 27.0 17.0 5.1 HD Opening H659-0121 2 200 UA291A-YFG ae -
Ringless OH/UG 1/0-600 kcmil #6-350 kcmil None 32.0 14.5 5.1 HD Opening H659-0121 3 200 UA3717-YG a UA3737-YG a
Ringless OH/UG 1/0-600 kcmil #6-350 kcmil None 32.0 14.5 5.1 HD Cl. Plate H659-0121 3 200 UA3717-ZG a -
Ringless OH/UG 1/0-600 kcmil #6-350 kcmil None 32.0 14.5 5.1 HD Cl. Plate H659-0121 3 200 UA3717-ZGF c UA3737-ZGF c
Ringless OH/UG #6-350 kcmil #6-350 kcmil Horn 32.0 14.5 5.1 HD Opening H659-0121 3 200 UA3717-YPQG b -
Ringless OH/UG 1/0-600 kcmil #6-350 kcmil Horn 32.0 14.5 5.1 HD Opening H659-0121 3 200 UA3717-YPGPe -
Ringless OH/UG 1/0-600 kcmil #6-350 kcmil Horn 32.0 14.5 5.1 HD Opening H659-0121 3 200 UA3717-YPRG -
Ringless OH/UG 1/0-600 kcmil #6-350 kcmil Horn 32.0 14.5 5.1 HD Opening H659-0121 3 200 UA3717-YPZAf -
Ringless OH/UG 3/8-24 Stud #6-350 kcmil None 32.0 17.0 5.1 HD Opening H659-0121 3 200 UA391A-YFG ae -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil None 43.0 14.5 5.1 HD Opening H659-0121 4 200 UA4719-YG a UA4739-YG a
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil None 43.0 14.5 5.1 HD Cl. Plate H659-0121 4 200 UA4719-ZG a -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil None 43.0 14.5 5.1 HD Cl. Plate H659-0121 4 200 UA4719-ZGF c UA4739-ZGF c
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil Horn 43.0 14.5 5.1 HD Opening H659-0121 4 200 UA4719-YPQG b -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil Horn 43.0 14.5 5.1 HD Opening H659-0121 4 200 UA4719-YPGPe -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil Horn 43.0 14.5 5.1 HD Opening H659-0121 4 200 UA4719-YPRG -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil Horn 43.0 14.5 5.1 HD Opening H659-0121 4 200 UA4719-YPZAf -
Ringless OH/UG 3/8-24 Stud #6-350 kcmil None 43.0 17.0 5.1 HD Opening H659-0121 4 200 UA491A-YFG ae -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil None 51.0 14.5 5.1 (2) HD Openings H659-0121 5 200 UA5719-KG a UA5739-KG a
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil None 51.0 14.5 5.1 (2) HD Cl. Plates H659-0121 5 200 UA5719-MG a -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil None 51.0 14.5 5.1 (2) HD Cl. Plates H659-0121 5 200 UA5719-MGF c UA5739-MGF c
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil Horn 51.0 14.5 5.1 (2) HD Openings H659-0121 5 200 UA5719-KPQG b -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil Horn 51.0 14.5 5.1 (2) HD Openings H659-0121 5 200 UA5719-KPGPe -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil Horn 51.0 14.5 5.1 (2) HD Openings H659-0121 5 200 UA5719-KPRG -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil Horn 51.0 14.5 5.1 (2) HD Openings H659-0121 5 200 UA5719-KPZAf -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil None 59.0 14.5 5.1 (2) HD Openings H659-0121 6 200 UA6719-KG a UA6739-KG a
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil None 59.0 14.5 5.1 (2) HD Cl. Plates H659-0121 6 200 UA6719-MG a -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil None 59.0 14.5 5.1 (2) HD Cl. Plates H659-0121 6 200 UA6719-MGF c UA6739-MGF c
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil Horn 59.0 14.5 5.1 (2) HD Openings H659-0121 6 200 UA6719-KPQG b -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil Horn 59.0 14.5 5.1 (2) HD Openings H659-0121 6 200 UA6719-KPGPe -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil Horn 59.0 14.5 5.1 (2) HD Openings H659-0121 6 200 UA6719-KPRG -
Ringless OH/UG (2) 1/0-600 kcmil #6-350 kcmil Horn 59.0 14.5 5.1 (2) HD Openings H659-0121 6 200 UA6719-KPZAf -
Ring-Style OH/UG 1/0-500 kcmil #8-250 kcmil None 28.0 14.0 5.3 HD Opening H659-0121 2 200 UA2728-YMCO d -
Ring-Style OH/UG 1/0-500 kcmil #8-250 kcmil None 38.0 14.0 5.3 HD Opening H659-0121 3 200 UA3728-YMCO d -
Ring-Style OH/UG 1/0-500 kcmil #8-250 kcmil None 48.0 14.0 5.3 HD Opening H659-0121 4 200 UA4728-YMCO d -
a Ground lug included.
b 2 ground lugs included.
e 7/8” Barrel Lock Provision, KO and Bracket Installed.
f 7/16” Barrel Lock Provision, KO and Bracket Installed.
Product Schedule 416
200A MULTI-POSITION METER MOUNTING DEVICES
UA291A-YFG
Common Features
J 200A continuous duty rated per position
J Factory installed lugs or studs
J Ground lug on all devices
J Lay-in line side lugs
J Steel or aluminum construction
J Glass-filled polyester block construction
J Available with or without barrel lock provision
J OH and UG capabilities
c Stainless steel latch and hasp.
d Lugs must be reversed for OH feed in the field.
15
Capacity: 200 ampere continuous per position.
Application: Single phase, 3 wire self-contained, convertible to five terminal.
Enclosures: All enclosures shown here are ringless. All enclosures are available in either 16 gauge painted steel or .063 aluminum in
natural finish. (For painted aluminum or ring-style enclosures, consult factory). All enclosures are NEMA type 3R.
Bypass: Optional horn-type available. Consult factory.
Terminals: Wiring terminals are lay-in style tin-plated extruded aluminum 6063-T6 or equivalent.
UL: All sockets are available with UL label.
ANSI-C12.7: All sockets meet or exceed ANSI-C12.7 standards.
5th Terminal: Order kit 659-0121.
Hub Options: First character after ”-” in catalog number.
A 1” hub K 2 large openings
B 1-1/4” hub M 2 large CPs
C 1-1/2” hub N Large-to-small adapter
D 2” hub O Small opening
E 2-1/2” hub P No hub opening
F 3” hub Y Large opening
G 3-1/2” hub Z Large CP
H 4” hub
NOTE: Small hub opening accepts interchangeable hubs from 1” to 2-1/2”. Large hub opening accepts interchangeable hubs from 3” to 4”.
To adapt large opening to small opening, order catalog number 9747-1112 (steel) or 9747-1113 (aluminum).
GENERAL INFORMATION:
Optional
Field Installable
5th Terminal
Product Schedule 416
200A MULTI-POSITION METER MOUNTING DEVICES
KNOCKOUTS (inches):
B: 1/2, 3/4
X: 1-1/4, 1-1/2, 2, 2-1/2
AC: 1/4, 1/2
AD: 1-1/4, 1-1/2, 2, 2-1/2, 3
HD: x4.281 HUB 0P
16
Common Features
J 200A continuous duty rated
J Silver brazed meter jaw
J 100% rated lever bypass w/clamping
action on meter
J Lay-in 350 kcmil max lugs
J Steel or aluminum construction
J Glass filled polyester block construction
J Field addable 5th terminal
J Track resistant lexan shield
J Plated copper current path
J Ringless style cover
TYPE HQ/HQU 4 TERMINAL CLAMPING JAW LEVER BYPASS METER MOUNTING EQUIPMENT
Cont.
Ampere Terminal Dimensions (in.) Hub Barrel Lock No. of 5th Jaw Catalog No.
Rating Service Connector W H D Opening KO Prov. Terminals Kit c Steel Aluminum Type
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 4 H35815-2 40804-01QG a - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Cl. Plate N/A 4 H35815-2 40804-02 - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 4 H35815-2 40804-016 a - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 4 H35815-2 40804-01 - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 2” Hub Inst. N/A 4 H35815-2 40824-02 41824-02 HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 2” Hub Inst. N/A 4 H35815-2 40824-026 a - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 2” Hub Inst. N/A 4 H35815-2 40824-0202 - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 2.5” Hub Inst. N/A 4 H35815-2 40834-02 - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 2.5” Hub Inst. N/A 4 H35815-2 40834-026 a - HQ
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 4 H35815-2 40404-02QG b - HQ
200 UG #6-350 kcmil 10.0 17.0 5.2 Blank Top N/A 4 H35815-2 40404-05 - HQU
200 OH/UG #6-350 kcmil 10.0 17.0 5.2 RX Opening N/A 4 H35815-2 40404-015 41404-015F HQU
200 OH/UG #6-350 kcmil 10.0 17.0 5.2 RX Cl. Plate N/A 4 H35815-2 40404-025 - HQU
200 UG #6-350 kcmil 13.0 19.0 5.2 Blank Top N/A 4 H35815-2 40404-056 a - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening N/A 4 H35815-2 40404-0150 a - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 4 H35815-2 40404-0250 a - HQU
200 UG #6-350 kcmil 13.0 19.0 5.2 Blank Top N/A 4 H35815-2 40404-9 - HQU
200 UG #6-350 kcmil 13.0 19.0 5.2 Blank Top N/A 4 H35815-2 40404-906 a - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 2” Hub Inst. N/A 4 H35815-2 40424-025 - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 2.5” Hub Inst. N/A 4 H35815-2 40434-025 - HQU
a Includes ground lug 36503, #14-2/0.
b Includes 2 ground lugs.
c Kit includes new shield and 5th jaw at 9:00. Lead not included.
Consult the factory for other available options such as,
but not limited to 5th terminals, alternate hasp material,
aluminum enclosures and special labeling.
40404-025
KNOCKOUTS (inches):
: 1/4
A: 1/2
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
AF: 1, 1-1/2, 2, 2-1/2, 3
AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
RX: x2.750 HUB 0P
Product Schedule 420
17
Capacity: 200 ampere continuous, 600 volts a.c.
Application: Single phase 3 wire self-contained, 4 terminal (convertible to 5 terminal).
Enclosures: Constructed of 16 gauge G90 galvanized steel and coated with light gray polyester powder coat finish for maximum corrosion
protection. Consult factory for alternate .080 aluminum construction. Latches are made from series 300 stainless steel.
All enclosures are NEMA type 3R.
Block Assembly: Glass fiber reinforced polyester. High strength arc and track resistant.
Bypass: Lever operated jaw release. Full 200 ampere rating. Moving lever up bypasses meter and releases pressure on meter jaws.
Cover cannot be replaced with lever in bypass position.
Terminals: Types HQ-4G and HQ-4GU are lay-in type with dome point screw. Rated for conductors from #6 to 350 MCM CU/AL.
Hubs: Single removable gasketless hub, conforms to ANSI C12.7 specifications for interchangeability.
UL: All units are UL listed.
Safety Shield: Track resistant polycarbonate insulating safety shield provides added protection from accidental shorts and shocks.
Ground Lug: Optional ground lug available. Consult factory.
Torque: Wire connections: 400 in. - lbs.
GENERAL INFORMATION:
CONNECTIONS:
all HQ
4 Terminal
all HQ
5 Terminal
all HQ
5 Terminal
all HQ
5 Terminal
Product Schedule 420
18
Common Features
J 200A continuous duty rated
J Silver brazed connections
J 100% rated lever bypass w/clamping
action on meter
J Lay-in 350 kcmil max lugs
J Steel or aluminum construction
J Glass filled polyester block construction
J 5th terminal placement in 3/6/9 o’clock
positions
J Track resistant lexan shield
J Plated copper current path
J Ringless style cover
TYPE HQ/HQU/HQUW 5 TERMINAL CLAMPING JAW LEVER BYPASS METER MOUNTING EQUIPMENT
Cont.
Amp Terminal Dimensions (in.) Hub Barrel Lock No. of 5th Jaw Catalog Numbers
Rating Service Connector W H D Opening KO Prov. Terminals Position Steel Aluminum Type
200 OH #6-350 kcmil 10.0 17.5 5.2 3” Hub Inst. N/A 5 6:00 40045 a - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 5 6:00 40005-01 a - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 5 9:00 40005-013 a - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 5 9:00 40005-01F ad 41005-01F ad HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening 7/16” 5 6:00 40005-01NU a - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 5 6:00 40005-01QG b - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening 7/16” 5 6:00 40005-02 a - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 5 6:00 40005-02F ad - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening 7/16” 5 9:00 40005-0BNU - HQ
125 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 5 6:00 40005-B2F ad - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 2” Hub Inst. N/A 5 6:00 40025-02 a - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 2” Hub Inst. N/A 5 9:00 40025-02F ad - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 2” Hub Inst. 7/8” 5 9:00 40025-02SP - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 2.5” Hub Inst. N/A 5 6:00 40035-02 a 41035-02 a HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 1.25” Hub Inst. N/A 5 6:00 40095-0202 a - HQ
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening 7/16” 5 9:00 40405-0BNU - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening 7/16” 5 6:00 40405-01NU a - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 5 6:00 40405-02CD - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening 7/8” 5 9:00 40405-02CO - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening N/A 5 6:00 40405-02QG b - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 7/8” 5 9:00 40405-02SP - HQU
200 UG #6-350 kcmil 13.0 19.0 5.2 Blank Top N/A 5 6:00 40405-05 a - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening N/A 5 6:00 40405-015 a - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening N/A 5 6:00 40405-015F ad 41405-015F ad HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 5 6:00 40405-025 a - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 5 9:00 40405-025F ad 41405-025F ad HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 5 6:00 - 41405-02PT ac HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 2.5” Hub Inst. N/A 5 6:00 40435-025 a - HQU
200 OH/UG #6-350 kcmil 16.0 22.0 5.2 RX Cl. Plate 7/16” 5 9:00 48805-0BNU a - HQUW
a Includes ground lug 36503, #14-2/0.
b Includes 2 ground lugs.
Consult the factory for other available options such as, but not limited to insulated 5th
terminals, alternate hasp material, aluminum enclosures, alternate 5th jaw placement and
special labeling.
KNOCKOUTS (inches):
: 1/4
A: 1/2
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
AF: 1, 1-1/2, 2, 2-1/2, 3
AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
RX: x2.750 HUB 0P
40005-01F
Product Schedule 421
c Painted aluminum.
d Stainless steel latch and hasp.
19
Capacity: 200 ampere continuous, 600 volts a.c.
Application: Single phase 3 wire self-contained, 5 terminal. 3 phase, 3 wire when used with isolated neutral.
Enclosures: Constructed of 16 gauge G90 galvanized steel and coated with light gray polyester powder coat finish for maximum corrosion
protection. Consult factory for alternate .080 aluminum construction. Latches are made from series 300 stainless steel.
Block Assembly: Glass fiber reinforced polyester. High strength arc and track resistant. All enclosures are NEMA type 3R.
Bypass: Lever operated jaw release. Full 200 ampere rating. Moving lever up bypasses meter and releases pressure on meter jaws.
Cover cannot be replaced with lever in bypass position.
Terminals: Types HQ-5 and HQ-5U are lay-in type with dome point screw. Rated for conductors from #6 to 350 MCM CU/AL.
Hubs: Single removable gasketless hub, conforms to ANSI C12.7 specifications for interchangeability.
UL: All units are UL listed.
Safety Shield: Track resistant polycarbonate insulating safety shield provides added protection from accidental shorts and shocks.
Ground Lug: Optional ground lug available. Consult factory.
Torque: Wire connections: 400 in. - lbs.
GENERAL INFORMATION:
CONNECTIONS:
all HQ
4 Terminal
all HQ
5 Terminal
all HQ
5 Terminal
all HQ
5 Terminal
Product Schedule 421
20
Common Features
J 200A continuous duty rated
J Silver brazed connections
J 100% rated lever bypass w/clamping
action on meter
J Lay-in 350 kcmil max lugs
J Steel or aluminum construction
J Glass filled polyester block construction
J Track resistant lexan shield
J Plated copper current path
J Ringless style cover
TYPE HQ/HQU 7 TERMINAL CLAMPING JAW LEVER BYPASS METER MOUNTING EQUIPMENT
Consult the factory for other available options such as, but
not limited to alternate hasp material, aluminum enclosures,
hubs, alternate enclosure sizes and special labeling.
40407-025
Cont.
Amp Terminal Dimensions (in.) Hub Barrel Lock
No. of Catalog Numbers
Rating Service Connector W H D Opening KO Prov.
Terminals Steel Aluminum Type
200 OH #6-350 kcmil 10.0 17.5 5.2 3” Hub Inst. N/A 7 40047 - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 7 40007-01 - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 7 40007-016 - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 7 40007-01F a d 41007-01F a d HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening 7/8” 7 40007-01GP a - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening 7/8” 7 40007-01NM - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening 7/16” 7 40007-01NU a - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Opening N/A 7 40007-01QG b - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 RX Cl. Plate N/A 7 40007-02 - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 2” Hub Inst. N/A 7 40027-02 - HQ
200 OH #6-350 kcmil 10.0 17.5 5.2 2.5” Hub Inst. N/A 7 40037-02 - HQ
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening N/A 7 40407-015 - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening N/A 7 40407-015F ad 41407-015F ad HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening 7/16” 7 40407-01NU a - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 7/8” 7 40407-02SP - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 7 40407-025 - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 7 40407-0250 a - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 7 40407-025F ad 41407-025F ad HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 7/8” 7 40407-02CO - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 7 40407-02QG b - HQU
200 UG #6-350 kcmil 13.0 19.0 5.2 Blank Top N/A 7 40407-05 - HQU
200 UG #6-350 kcmil 13.0 19.0 5.2 Blank Top N/A 7 40407-056 - HQU
200 UG #6-350 kcmil 13.0 19.0 5.2 Blank Top N/A 7 40407-9 - HQU
200 UG #6-350 kcmil 13.0 19.0 5.2 Blank Top N/A 7 40407-906 a - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 7 40417-025 - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 2” Hub Inst. N/A 7 40427-025 - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 2.5” Hub Inst. N/A 7 40437-025 - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 7 - 41407-01PT ac HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 7 - 41407-02PT ac HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 HD Opening (large) N/A 7 44307-9102 - HQU
200 OH/UG #6-350 kcmil 13.0 19.0 5.2 HD Opening (large) N/A 7 44307-92 - HQU
KNOCKOUTS (inches):
: 1/4
A: 1/2
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
AF: 1, 1-1/2, 2, 2-1/2, 3
AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
RX: x2.750 HUB 0P
a Includes ground lug 36503, #14-2/0.
b Includes 2 ground lugs.
c Painted aluminum.
d Stainless steel latch and hasp.
Product Schedule 422
21
Capacity: 200 ampere continuous, 600 volts a.c.
Application: 3 phase, 4 wire wye or 4 wire delta services using self-contained Class 100 or Class 200 meters.
Enclosures: Ringless cover. Constructed of 16 gauge galvannealed steel with polyester powder finish, suitable for indoor or outdoor
installations. Also available in 12 gauge aluminum. All enclosures are NEMA type 3R.
Block Assembly: Glass fiber reinforced polyester. High strength arc and track resistant.
Bypass: Lever operated jaw release. Full 200 ampere bypass capacity. Moving lever up closes bypass and releases pressure on meter
terminals. Cover cannot be replaced with lever in bypassed position.
Terminals: Lay-in type with dome point screw. Conservatively rated at 200 amperes, terminals will accommodate conductors from #1 to
350 MCM copper or aluminum.
Hubs: Single removable gasketless hub, cover plate or no hub. Hubs and cover plate are interchangeable.
UL: All units are UL listed for use on loads up to 200 amperes; 600 volts a.c.
Safety Shield: Polycarbonate track resistant insulating safety shield provides protection from accidental shorts and shocks.
Torque: Wire connections: 400 in. - lbs.
GENERAL INFORMATION:
CONNECTIONS:
all HQ-7
all HQ-7
SOLIDLY GROUNDED
NEUTRAL CONNECTION
Product Schedule 422
22
TYPE HQSU CLAMPING JAW LEVER BYPASS METER MOUNTING EQUIPMENT
Continuous Terminal Dimensions (inches) Hub Barrel Lock No.of Catalog
Ampere Rating Service Connector W H D Opening KO Prov. Terminals Number Type
200 OH/UG #6-350 kcmil (55890) 13.0 19.0 5.2 RX Cl. Plate N/A 4 9804-8714 HQSU
200 OH/UG (2) #6-250 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 4 9804-8715 HQSU
200 OH/UG 3/8-24 Stud 13.0 19.0 5.2 2.5” Hub Installed N/A 4 9804-8716 HQSU
200 OH/UG #6-350 kcmil (55890) 13.0 19.0 5.2 2.5” Hub Installed N/A 4 9804-8717 HQSU
200 OH/UG (2) #6-250 kcmil 13.0 19.0 5.2 2.5” Hub Installed N/A 4 9804-8718 HQSU
200 UG #6-350 kcmil (55890) 13.0 19.0 5.2 Blank Top N/A 4 9804-8739 HQSU
200 OH/UG #6-350 kcmil (55890) 13.0 19.0 5.2 2” Hub Installed N/A 4 9804-8740 HQSU
200 OH/UG (2) #6-250 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 4 9804-8745 HQSU
200 OH/UG 3/8-24 Stud 13.0 19.0 5.2 RX Cl. Plate N/A 4 42504-025 HQSU
200 OH/UG 3/8-24 Stud 13.0 19.0 5.2 RX Cl. Plate N/A 4 42504-0250 a HQSU
200 OH/UG 3/8-24 Stud 13.0 19.0 5.2 RX Cl. Plate N/A 5 42505-025 HQSU
200 OH/UG #6-350 kcmil (55890) 13.0 19.0 5.2 RX Cl. Plate N/A 5 42505-0251 HQSU
200 OH/UG 3/8-24 Stud 13.0 19.0 5.2 RX Cl. Plate 7/8” 5 42505-02RG HQSU
200 UG 3/8-24 Stud 13.0 19.0 5.2 Blank Top N/A 5 42505-05 HQSU
200 OH/UG #6-350 kcmil (55890) 13.0 19.0 5.2 2” Hub Installed N/A 5 42525-0251 HQSU
200 OH/UG #6-350 kcmil (55890) 13.0 19.0 5.2 RX Opening N/A 7 42507-0151 HQSU
200 OH/UG #6-350 kcmil (55890) 13.0 19.0 5.2 RX Opening N/A 7 42507-0161 a HQSU
200 OH/UG 3/8-24 Stud 13.0 19.0 5.2 RX Cl. Plate N/A 7 42507-025 HQSU
200 OH/UG #6-350 kcmil (55890) 13.0 19.0 5.2 RX Cl. Plate N/A 7 42507-0251 HQSU
200 OH/UG 3/8-24 Stud 13.0 19.0 5.2 RX Cl. Plate 7/8” 7 42507-02NM HQSU
200 UG 3/8-24 Stud 13.0 19.0 5.2 Blank Top N/A 7 42507-05 HQSU
200 UG #6-350 kcmil (55890) 13.0 19.0 5.2 Blank Top N/A 7 42507-9001 HQSU
200 OH/UG #6-350 kcmil (55890) 13.0 19.0 5.2 2” Hub Installed N/A 7 42527-0251 HQSU
200 OH/UG #6-350 kcmil (55890) 13.0 19.0 5.2 2.5” Hub Installed N/A 7 42537-0251 HQSU
200 OH/UG #6-350 kcmil (55890) 13.0 19.0 5.2 HD Opening (large) N/A 7 44407-0161 a HQSU
a Includes ground lug 36503, #14-2/0.
Consult the factory for other available options such as, but not
limited to alternate hasp material, aluminum enclosures, hubs,
alternate enclosure sizes, and special labeling.
42505-025
Common Features
J 200A continuous duty rated
J Silver brazed connections
J 100% rated lever bypass w/clamping
action on meter
J 3/8” stud connection - available with
bolt -on lugs
J Steel or aluminum construction
J Glass filled polyester block
construction
J Track resistant lexan shield
J Plated copper current path
J Ringless style cover
HQSU
KNOCKOUTS (inches):
: 1/4
A: 1/2
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
AF: 1, 1-1/2, 2, 2-1/2, 3
AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
RX: x2.750 HUB 0P
Product Schedule 423
23
Capacity: 200 ampere - 600 volts a.c.
Application: 4 Jaw: 1 phase, 3 wire, 5 Jaw: 1 or 3 phase, 3 wire, 7 Jaw: 3 phase, 4 wire
Enclosures: Adequately dimensioned for ease in wiring and constructed of 16 gauge steel with polyester powder coat finish for indoor or
outdoor installations. Also available in 12 gauge aluminum upon request. All enclosures are NEMA type 3R.
Block Assembly: Glass fiber reinforced polyester plastic. High strength arc and track resistant.
Bypass: Lever operated - full 200 ampere rating. Moving lever up closes bypass and releases pressure on meter terminals. Cover can
not be replaced with lever in bypassed position.
Terminals: 3/8” x 3/4” cold headed cadmium plated steel studs to accommodate various screw type or compression lugs for conductors to
350 MCM. Tin plated copper mounting plate is compatible with aluminum or copper lugs. Type HQ-4SU are 3/8” - 24 x 3/4”
plated steel studs to accommodate various screw-type or compression lugs up to single 350 MCM or parallel 250 MCM.
Hubs: No hub. 1 1/2”, 2” and 2 1/2” single removable hub construction. Interchangeable hubs and hub opening cover plates create a
“universal” mounting device for both underground and overhead service applications.
UL: Units with 425/444 prefix are UL listed.
Safety Shield: Polycarbonate track resistant transparent insulating safety shield provides protection from accidental shorts and shocks.
Torque: Lug connections: 400 in. - lbs., Wire connections: 300 in. - lbs.
GENERAL INFORMATION:
CONNECTIONS:
all HQ
4 Terminal
all HQ
5 Terminal
all HQ
5 Terminal
all HQ
5 Terminal
all HQ
7 Terminal
all HQ
7 Terminal
Product Schedule 423
24
Common Features
J Isolated neutral with disconnect
capability for use on 3 phase, 3 wire sys-
tems
J 200A continuous duty rated
J Silver brazed connections
J 100% rated lever bypass w/clamping
action on meter
J Lay-in 350 kcmil max lugs
J Steel or aluminum construction
J Glass filled polyester block construction
J Track-resistant lexan shield
J Plated copper current path
J Ringless style cover
TYPE HQND 5 TERMINAL CLAMPING JAW LEVER BYPASS METER MOUNTING EQUIPMENT W/NEUTRAL DISCONNECT
Cont.
Amp. Terminal Connectors Dimensions (in.) Hub Barrel Lock No. of 5th
Jaw Catalog No. Enclosure
Rating Service Line Load W H D Opening KO Prov. Term. Position Steel Material Type
200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 2” Hub Inst. N/A 5 6:00 9804-8578 a Steel HQND
200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 2.5” Hub Inst. N/A 5 6:00 9804-8579 a Steel HQND
200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 RX Cl. Plate N/A 5 6:00 9804-8583 a Steel HQND
200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 2-2.5” Hubs Inst. N/A 5 6:00 9804-8582 a Steel HQND
200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 2” Hub Inst. N/A 5 6:00 9804-8596 a Alum HQND
200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 2” Hub Inst. N/A 5 6:00 9804-8736 ac Alum HQND
200 OH #6-350 kcmil #6-350 kcmil 10.0 17.5 5.2 2” Hub Inst. N/A 5 6:00 9804-9106 a Steel HQND
200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 5 6:00 9804-8586 a Steel HQNDU
200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Opening N/A 5 6:00 9804-8591 a Steel HQNDU
200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A 5 6:00 9804-8592 a Steel HQNDU
200 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.2 2” Hub Inst. N/A 5 6:00 9804-9085 ab Steel HQNDU
200 OH/UG 3/8-24 Stud #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate N/A 5 6:00 9804-8986 Steel HQ5CND-2W
200 OH/UG #6-350 kcmil #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate N/A 5 6:00 9804-8991 d Steel HQ5CND-2W
200 OH/UG #6-350 kcmil #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate N/A 5 6:00 9804-9127 ad Steel HQ5CND-2W
a Includes ground lug 36503, #14-2/0.
b Bonded neutral also included.
c 480V warning label included.
d Line side lugs are 55890-1.
Consult the factory for other available options such as, but not limited to alternate hasp
material, aluminum enclosures, alternate 5th jaw placement and special labeling.
9804-8592
HQND HQNDU HQ-W KNOCKOUTS (inches):
: 1/4
A: 1/2
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
AC: 1/4, 1/2
AF: 1, 1-1/2, 2, 2-1/2, 3
AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
EE: 2, 2-1/2, 3
RX: x2.750 HUB 0P
Product Schedule 424
25
Capacity: 200 ampere continuous - 600 volts a.c.
Application: 1or 3 phase, 3 wire and 3 wire network services using self-contained Class 100 or Class 200 meters (ANSI form 12S). The
HQ-5ND and HQ-5NDU devices are specifically designed for 3 phase, 3 wire ungrounded services when it is desirable to open
the common phase and remove potential from the load when the meter is removed. The center phase is equipped with a 200
amp sliding clamp disconnect that is operable by a nut and captive Belleville washer.
Enclosures: Ringless cover. Constructed of 16 gauge galvannealed steel with polyester powder coat suitable for indoor or outdoor
installation. Also available in 12 gauge aluminum upon request. All enclosures are NEMA type 3R.
Block Assembly: Glass fiber reinforced polyester. High strength arc and track resistant.
Bypass: Lever operated jaw release. Full 200 ampere capacity. Moving lever up closes bypass and releases pressure on meter terminals.
Cover cannot be replaced with lever in bypassed position.
Terminals: Lay-in type with dome point screw. Conservatively rated at 200 amperes, terminals will accommodate conductors from #1 to
350 MCM copper or aluminum.
Hubs: Single removable gasketless hub, cover plate or no hub. Hubs and cover plate are interchangeable.
UL: These mounting devices are listed by UL for use on loads up to 200 amp 600 volts a.c.
Safety Shield: Track resistant polycarbonate insulating safety shield provides protection from accidental shorts and shocks.
GENERAL INFORMATION:
CONNECTIONS:
all HQ-5
all HQ-5 Type HQ-5CND-2W
Product Schedule 424
26
TYPE HQW 4, 5, 7 TERMINAL CLAMPING JAW LEVER BYPASS METER MOUNTING EQUIPMENT
Consult the factory for other available options such as, but not limited to alternate hasp
material, aluminum enclosures, 5 terminal devices and special labeling.
KNOCKOUTS (inches):
AC: 1/4,1/2
EE: 2, 2-1/2, 3
RX: x2.750 HUB 0P
9804-9142
Common Features
J Offset side wire design
J 200A continuous duty rated
J Silver brazed connections
J 100% rated lever bypass w/clamping
action on meter
J 350 kcmil max lugs or 3/8” stud
connections
J Steel or aluminum construction
J Glass filled polyester block construction
J Track resistant lexan shield
J Plated copper current path
J Ringless style cover
HQ-W
a Left side studs with lug 55890-1 installed.
b Off-set socket - no bussing.
c Ground lug, 36503, included
d Line and load studs with 55890-1 and 56732-2 lugs installed.
e Line side studs with lug 60162 installed.
f Neutral lug included - #55890.
Cont.
Amp Terminal Connector Dimensions (in.) Hub Barrel Lock No. of 5th Jaw Catalog Enclosure
Rating Service Line Load W H D Opening KO Prov. Terminals Kit Number Material Type
200 OH/UG 3/8-24 Stud 3/8-24 Stud 16.0 20.0 5.0 RX Cl. Plate N/A 4 H35815-2 9804-8926 Steel HQ4SW
200 OH/UG 3/8-24 Stud #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate N/A 4 H35815-2 9804-8946 c Steel HQ4-2W
200 OH/UG 3/8-24 Stud #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate N/A 4 H35815-2 9804-8947cf Steel HQ4-2W
200 OH/UG #6-350 kcmil #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate N/A 4 H35815-2 9804-8951 ab Steel HQ4-2W
200 OH/UG #6-350 kcmil (2) #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate N/A 4 H35815-2 9804-9124 bd Steel HQ4SW
200 OH/UG 3/8-24 Stud 3/8-24 Stud 16.0 20.0 5.0 RX Cl. Plate N/A 7 N/A 9804-9006 Steel HQ7SW
200 OH/UG 3/8-24 Stud #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate N/A 7 N/A 9804-9026 Steel HQ7-2W
200 OH/UG 3/8-24 Stud #6-350 kcmil 16.0 20.0 5.0 2.5” Hub Inst. N/A 7 N/A 9804-9027 Steel HQ7-2W
200 OH/UG #6-350 kcmil #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate N/A 7 N/A 9804-9031 ac Steel HQ7-2W
200 OH/UG #6-350 kcmil #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate N/A 7 N/A 9804-9034 ab Steel HQ7-2W
200 OH/UG 3/8-24 Stud #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate N/A 7 N/A 9804-9096 Steel HQ7-2W
200 OH/UG #6-350 kcmil #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate N/A 7 N/A 9804-9126 ac Steel HQ7-2W
200 OH/UG #4-600 kcmil #6-350 kcmil 16.0 20.0 5.0 RX Cl. Plate 7/8” 7 N/A 9804-9142 e Steel HQ7-2W
Product Schedule 425
27
Capacity: 200 ampere, 600 volts a.c.
Application: Single phase, 3 wire, 1, 2 or 3 phase, 3 wire, 3 phase, 4 wire wye or delta
Enclosures: Outdoor enclosure #16 gauge galvannealed steel with polyester powder coat finish.
Block Assembly: Glass fiber reinforced polyester. High strength arc and track resistant.
Bypass: Lever-arm bypass with jaw tension release. Cover cannot be closed with lever in bypass position. NOTE: Bypass is not for use as
a circuit interrupter.
Terminals: Stud-type terminals with lay-in or stud-type load terminals. Stud-type terminals are 3/8” - 24, zinc-plated steel studs with
Belleville washer nut assemblies for copper or aluminum lugs with up to 1/2” thick mounting tongue. Recommended lugs:
Talon numbers 57606, 57606-1, 55890, 55890-1, 58022. Lay-in type terminals with dome point screws are for copper
or aluminum wire from #1 AWG to 350 MCM.
UL: All units are UL listed.
Safety Shield: Track resistant polycarbonate safety shield provides protection against accidental shorts and shocks.
GENERAL INFORMATION:
CONNECTIONS:
Type HQ-4-2W or HQ-4SW Type HQ-7-2W or HQ-7SW
Product Schedule 425
28
TYPE HQ-4S 200A MULTI-POSITION LEVER BYPASS METER MOUNTING DEVICES
No. Cont.
of Amp Overall Connectors Dimensions (inches) Hub No. of Enclosure Catalog
Positions Rating Ampacity Service Line Load W H D Opening Term. Bypass b Material Number a
120/240V AC MAX 1 Phase 3 Wire
2 200 250 OH/UG 1/0-500 kcmil #6-350 kcmil 32.78 23.19 6.00 HD Coverplate 4 Lever Steel 404042-01
2 200 250 OH/UG 1/0-500 kcmil #6-350 kcmil 32.78 23.19 6.00 HD Coverplate 5 Lever Steel 404052-023NU cd
3 200 250 OH/UG 1/0-500 kcmil #6-350 kcmil 43.86 23.19 6.00 HD Coverplate 5 Lever Steel 404053-023NU cd
4 200 300 OH/UG (2) 1/0-500 kcmil #6-350 kcmil 61.00 23.19 6.00 (2) HD Cvrplates 5 Lever Steel 404054-223NU cd
5 200 300 OH/UG (2) 1/0-500 kcmil #6-350 kcmil 72.13 23.19 6.00 (2) HD Cvrplates 5 Lever Steel 404055-223NU cd
6 200 410 OH/UG (2) 1/0-500 kcmil #6-350 kcmil 83.16 23.19 6.00 (2) HD Cvrplates 5 Lever Steel 404056-223NU cd
600V AC MAX 3 Phase 4 Wire
2 200 410 OH/UG 1/0-500 kcmil #6-350 kcmil 32.78 23.19 6.00 HD Coverplate 7 Lever Steel 404072-023NUd
3 200 500 OH/UG 1/0-500 kcmil #6-350 kcmil 43.88 23.19 6.00 HD Coverplate 7 Lever Steel 404073-023NUd
4 200 500 OH/UG (2) 1/0-500 kcmil #6-350 kcmil 61.00 23.19 6.00 (2) HD Cvrplates 7 Lever Steel 404074-223NUd
5 200 620 OH/UG (2) 1/0-500 kcmil #6-350 kcmil 72.13 23.19 6.00 (2) HD Cvrplates 7 Lever Steel 404075-223NUd
6 200 608 OH/UG (2) 1/0-500 kcmil #6-350 kcmil 83.16 23.19 6.00 (2) HD Cvrplates 7 Lever Steel 404076-223NUd
a All units are UL listed and are equipped with a ground lug.
b Bypass is clamp jaw, lever operated and is rated for 100%.
404052-023NU
Common Features
J 200A/Position Continuous Duty
J 600 V AC Max Rating
J Lay-in 500 KCMIL line lugs
J High quality HQ lever bypass block
J 5th terminal installed on single phase devices
J Barrel lock knock out and bracket
J Hub enclosure plate installed
J Removable load side lugs
J Overhead/Underground capability
KNOCKOUTS (inches):
B: 1/2, 3/4
X: 1-1/4, 1-1/2, 2, 2-1/2
AC: 1/4, 1/2
AD: 1-1/4, 1-1/2, 2, 2-1/2, 3
HD: x4.281 HUB 0P
Product Schedule 426
c 5th Terminal included at 9:00 position.
d 7/16” Barrel Lock KO and Bracket Installed
29
Capacity: 200 ampere continuous, 310 ampere total ampacity, 600 volts a.c.
Application: HQ-4, single phase, 3 wire, 4 terminal (convertible to 5 terminal using shield assembly #35815-2 for grounded service only),
HQ7, 3 phase, 4 wire.
Enclosures: All enclosures shown here are ringless NEMA type 3R, 16 gauge painted steel.
Block Assy.: Block assemblies are arc and track resistant glass fiber reinforced polyester.
Bypass: Lever operated jaw release. Moving lever up closes bypass and unclamps meter blades. Bypass connection is completed before
meter blade is released, thus eliminating meter blade-to-jaw terminal arcing. The cover cannot be replaced with the lever in the
bypassed position. Bypass capacity: 200 amperes continuous.
Terminals: Terminals are 3/8”-24 cold headed, zinc-plated, steel studs with nuts and captive Belleville washers to accommodate various
pressure type lugs. The flat washer supplied must be installed directly beneath the Belleville washer.
UL: All sockets shown are UL. approved.
ANSI-C12.7: All sockets meet or exceed ANSI-C12.7 standards.
GENERAL INFORMATION:
CONNECTIONS:
all HQ-4 all HQ-5 all HQ-5 all HQ-5
all HQ-7 all HQ-7
Product Schedule 426
30
40605-025
Common Features
J 200A continuous duty rated
J 250A max. rated
J Ground lug available
J Lay-in 350 kcmil lugs
J Steel or aluminum construction
J Glass filled polyester block construction
J 100% rated bypass
J Overhead and underground capabilities
J 600V rated
J Strongest non-clamp jaw block available
J 5th Jaw Assembly Available - Use #H8059864
200A NON-CLAMPING LEVER BYPASS RESIDENTIAL/COMMERCIAL METER MOUNTING DEVICES TYPE MQ-U
Cover Dimension (Inches) Hub Barrel Lock 5th Jaw No. of Catalog Number d
Style Service Connectors W H D Opening KO Prov. (6) Kit No. Terminals With Lever Bypass Without Bypass
Ringless OH #6-300 kcmil f 10.0 17.5 5.2 RX Opening N/A H8059864 4 40204-01 -
Ringless OH #6-300 kcmil f 10.0 17.5 5.2 RX Opening N/A H8059864 4 40204-010 a -
Ringless OH #6-300 kcmil f 10.0 17.5 5.2 2” Hub Installed N/A H8059864 4 40224-02 43024-02
Ringless OH #6-300 kcmil f 10.0 17.5 5.2 2” Hub Installed N/A H8059864 4 40224-026 a -
Ringless OH #6-300 kcmil f 10.0 17.5 5.2 2.5” Hub Installed N/A H8059864 4 40234-02 -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening N/A H8059864 4 40604-015 -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A H8059864 4 40604-025 43104-025
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A H8059864 4 40604-0250 a 43104-0250 a
Ringless UG #6-350 kcmil 13.0 19.0 5.2 Blank Top N/A H8059864 4 40604-05 -
Ringless UG #6-350 kcmil 13.0 19.0 5.2 Blank Top N/A H8059864 4 40604-056 a -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 2” Hub Installed N/A H8059864 4 40624-025 -
Ringless OH #6-300 kcmil f 10.0 17.5 5.2 RX Opening N/A Factory Inst. 5 40205-01 -
Ringless OH #6-300 kcmil f 10.0 17.5 5.2 RX Cl. Plate N/A Factory Inst. 5 40205-02 -
Ringless OH #6-300 kcmil f 10.0 17.5 5.2 2.5” Hub Installed N/A Factory Inst. 5 40235-02 -
Ringless OH #6-300 kcmil f 10.0 17.5 5.2 RX Opening 7/16” Factory Inst. 5 40205-01NU -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening 7/16” Factory Inst. 5 40605-02NU -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 7/8” Factory Inst. 5 40605-02BU -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A Factory Inst. 5 40605-02DU -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A Factory Inst. 5 40605-025 -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening N/A Factory Inst. 5 42905-01 b -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Opening N/A Factory Inst. 5 42905-01SP c -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A Factory Inst. 5 - 43125-025
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A Factory Inst. 5 - 43125-0250 a
Ringless OH #6-250 kcmil f 10.0 17.5 5.2 RX Opening N/A N/A 7 40307-01 -
Ringless OH #6-250 kcmil f 10.0 17.5 5.2 RX Opening 7/8” N/A 7 40307-01BU a -
Ringless OH #6-250 kcmil f 10.0 17.5 5.2 RX Opening 7/16” N/A 7 40307-01NU a -
Ringless OH #6-250 kcmil f 10.0 17.5 5.2 RX Cl. Plate N/A N/A 7 40307-02 -
Ringless OH #6-250 kcmil f 10.0 17.5 5.2 2” Hub Installed N/A N/A 7 40327-02 -
Ringless OH #6-250 kcmil f 10.0 17.5 5.2 2” Hub Installed N/A N/A 7 40327-026 a -
Ringless OH #6-250 kcmil f 10.0 17.5 5.2 2.5” Hub Installed N/A N/A 7 40337-02 -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 7/8” N/A 7 40607-02BU a -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate 7/16” N/A 7 40607-01NU a -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A N/A 7 N40607-025 -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A N/A 7 N40607-0250 a 43107-02NB a
Ringless UG #6-350 kcmil 13.0 19.0 5.2 Blank Top N/A N/A 7 N40607-05 -
Ringless OH/UG #6-350 kcmil 13.0 19.0 5.2 2” Hub Installed N/A N/A 7 N40627-025 -
Ring Type OH/UG #6-350 kcmil 13.0 19.0 5.2 RX Cl. Plate N/A N/A 7 - 30407-025 a
Ringless OH #6-2/0 kcmil f 10.0 17.5 5.2 RX Opening 7/16” Factory Inst. 5 48205-01NUae -
Ringless OH #6-2/0 kcmil f 10.0 17.5 5.2 RX Opening 7/16” N/A 7 48207-01NUae -
Ringless OH/UG #6-2/0 kcmil f 13.0 19.0 5.2 RX Cl. Plate 7/16” Factory Inst. 5 48405-02NUae -
a Ground lug included.
b Isolated, bonded neutral.
10 x 17.5 x 5.2 13.0 x 19.0 x 5.2
KNOCKOUTS (inches):
: 1/4
A: 1/2
B: 1/2, 3/4
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
AF: 1, 1-1/2, 2, 2-1/2, 3
AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
RX: x2.750 HUB 0P
Product Schedule 428
c Isolated, non-bonded neutral.
d All catalog numbers are steel construction.
Contact factory for aluminum.
e Derated and marked for 125A continuous.
f Wire size limited due to wire bend space and/or
labeling restrictions.
31
Capacity: 200 ampere continuous, 600 volts a.c.
Application: 1 phase, 3 wire; 3 phase, 4 wire wye or 4 wire delta services using self-contained Class 100 or Class 200 meters.
Enclosures: Constructed of 16 gauge galvannealed steel with polyester powder finish, suitable for indoor or outdoor installation. Also
available in aluminum and different sizes upon request. All boxes have ringless covers. All enclosures are NEMA type 3R.
Block Assembly: Glass fiber reinforced polyester mounted on metal baseplate. High strength, arc and track resistant.
Bypass: Lever-operated. Moving lever up closes bypass. Cover cannot be replaced with lever in bypassed position. Bypass capacity:
200 amperes continuous.
Terminals: Lay-in type with dome point screw. Conservatively rated at 200 amperes, terminals will accommodate conductors from
#6-350 kcmil copper or aluminum.
Safety Shield: Track resistant polycarbonate insulating safety shield provides protection from accidental shorts and shocks.
Hubs: Single, removable, gasketless hub; cover plate, or no hub. Hubs and cover plate are interchangeable.
UL: These mounting devices are listed by UL for use on continuous loads up to 200 amperes and 600 volts.
ANSI-C12.7: All sockets meet or exceed ANSI-C12-7 standards.
1) Select service feed and bypass requirements 406 0 7 - 0 2 50
2) Select hub style
3) Select number of terminals
Consult the factory for other available options such as, but not
limited to alternate enclosure and hasp material, kearnaloxed
terminals, enclosures with multiple hub openings and special labeling.
402/403 = OH only
406 = OH/UG
430 = OH-no BPS
431 = OH/UG-no BPS
304 = Ring Style
482 = OH only: 125A
484 = OH/UG: 125A 1 = Hub Opening
2 = Cover Plate or Hub
Installed
5 = Blank Top
Blank = 3” KO on bottom
only
5 = 3” KO back and
bottom
0/6 = Ground Lug
included
BU = 7/8” Barrel Lock KO
NU = 7/16” Barrel Lock
KO
1 - 6 = 1.5” - 4” Hub
0 = No hub installed
4 = 4 Terminal
5 = 5 Terminal
7 = 7 Terminal
Place Holder
CUSTOMIZED CATALOG NUMBER:
GENERAL INFORMATION:
CONNECTIONS:
all MQ
4 Terminal
all MQ
5 Terminal
all MQ
5 Terminal
all MQ
5 Terminal
all MQ
7 Terminal
all MQ
7 Terminal
Product Schedule 428
32
a 60162 and 61300 lugs are also rated for (2) 250 kcmil.
b 56732-1 lugs on line and load side.
c 55890 lugs on line and load side.
d 58022 lugs on line and load side.
Cont.
Cover Amp Terminal Connector Dimensions (in.) Hub Barrel Lock No. of 5th Jaw Catalog Number
Style Rating Service Line Load W H D Opening KO Prov. Term. Kit Steel Aluminum Type
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 13 28 5 HD Opening N/A 4
H35815-2
47604-01FL
fh 47604-A1FL fh HQ4ST
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 13 28 5 HD Cl. Plate N/A 4
H35815-2
47604-02
- HQ4ST
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 13 28 5 HD Cl. Plate N/A 4
H35815-2
47604-02QG
f - HQ4ST
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 13 28 5 HD Opening 7/8” 4
H35815-2
47604-81GP
a - HQ4ST
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 13 28 5 HD Cl. Plate N/A 4
H35815-2
47604-82
a - HQ4ST
Ringless 320 OH/UG (2) #6-350 kcmil (2) #6-350 kcmil 13 28 5 HD Cl. Plate N/A 4 H
35815-2 47604-8203
b - HQ4ST
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 13 28 5 HD Opening N/A 5 Installed
47605-015F
fh 47605-A15F fh HQ5ST
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 13 28 5 HD Cl. Plate N/A 5 Installed
47605-02FL
fh 47105-02FL fh HQ5ST
Ringless 320 OH/UG (2) #6-350 kcmil (2) #6-350 kcmil 13 28 5 2.5” Hub Inst. N/A 4 H
35815-2 47634-8103
e - HQ4ST
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 13 28 5 3” Hub Inst. N/A 4 H
35815-2 47644-82
a - HQ4ST
Ringless 320 UG 3/8”-24 Stud 3/8”-24 Stud 13 28 5 Blank Top N/A 4 H
35815-2 48504-92
g - HQ4SUT
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 13 19 5 HD Cl. Plate N/A 4 H
35815-2 9804-8713
- HQ4ST
-non UL
Ringless 320 OH/UG #6-350 kcmil #6-350 kcmil 13 19 5 HD Cl. Plate N/A 4 H
35815-2 9804-8714
c - HQ4ST
-non UL
Ringless 320 OH/UG (2) #6-250 kcmil (2) #6-250 kcmil 13 19 5 HD Cl. Plate N/A 4 H
35815-2 9804-8715
d - HQ4ST
-non UL
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 13 19 5 2.5” Hub Inst. N/A 4 H
35815-2 9804-8716
- HQ4ST
-non UL
Ringless 320 OH/UG #6-350 kcmil #6-350 kcmil 13.0 19.0 5.0 2.5” Hub Inst. N/A 4 H
35815-2 9804-8717
c - HQ4ST
-non UL
Ringless 320 OH/UG (2) #6-250 kcmil (2) #6-250 kcmil 13.0 19.0 5.0 2.5” Hub Inst. N/A 4 H
35815-2 9804-8718
d - HQ4ST
-non UL
Ringless 200 OH/UG 3/8”-24 Stud 3/8”-24 Stud 13 28 5 HD Opening N/A 5 Installed
47605-01FL
h - HQ5ST
Ringless 200 OH/UG 3/8”-24 Stud 3/8”-24 Stud 13 28 5 HD Cl. Plate N/A 5 Installed
46705-025F
fh - HQ5ST
Ringless 200 OH/UG 3/8”-24 Stud 3/8”-24 Stud 13 28 5 HD Cl. Plate N/A 7 N/A
46707-025F
fh - HQ7ST
Ringless 200 OH/UG 3/8”-24 Stud 3/8”-24 Stud 13 28 5 HD Opening N/A 7 N/A
47607-01FL
h - HQ7ST
e 56732 lugs on line and load side.
f Includes ground lug #67554.
g UG only design-wire cables straight in, socket has been moved up.
h Includes stainless steel latch and hasp.
Common Features
J 320A continuous duty rated
J Silver-brazed connections
J 100% rated lever bypass w/clamping action
on meter
J Factory installed lugs or 3/8” stud connection
J Steel or aluminum construction
J Glass-filled polyester block construction
J Track-resistant lexan shield
J Plated copper current path
TYPE HQST 4-7 TERMINAL CLAMPING JAW LEVER BYPASS METER MOUNTING EQUIPMENT
Consult the factory for other available options such as,
but not limited to alternate hasp material, aluminum
enclosures, 5 terminal devices and special labeling.
47607-01FL
Anti-Inversion
Wire Insert
(optional)
#H59676
KNOCKOUTS (inches):
: 1/4
A: 1/2
Z: 1-1/2, 2, 2-1/2
AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
HD: x4.281 HUB 0P
Product Schedule 430
33
Capacity: 320 ampere continuous, 400 ampere maximum, when wired to National Electrical Code ampacity; 600 volts a.c.
Application: 4 jaw: 1 phase, 3 wire, 5 jaw: 1 or 3 phase, 3 wire, 7 jaw: 3 phase, 4 wire.
Enclosures: Constructed of galvannealed steel with polyester powder finish. All boxes have a ringless cover. All enclosures are NEMA type 3R.
Block Assembly: Glass fiber reinforced polyester plastic. High strength arc and track resistant.
Bypass: Lever-operated jaw release. Moving lever up closes bypass and unclamps meter blades. Bypass connection is completed before
meter blade is released, thus eliminating meter blade to jaw terminal arcing The cover cannot be replaced with the lever in the
bypassed position. Bypass capacity: 320 amperes continuous.
Terminals: 3/8” - 24 cold-headed zinc-plated steel studs with nuts and captive Belleville washers to accommodate various pressure type
lugs. The flat washer supplied must be installed directly beneath the Belleville washer.
Lugs: Six lugs are required for the HQ-4S mounting device, eight for HQ7S.
UL: All units are UL listed.
Safety Shield: Track resistant transparent polycarbonate insulating safety shield provides protection from accidental shorts and shocks.
Anti-Inversion An optional wire-type jaw insert (#H59676) can be used with HQ-4S to prevent inverted installation of Talon Class 320
Insert: single phase meters. The insert rejects normal width terminal blades, yet admits the Talon Class 320 narrower upper
right-hand blade. The insert is field-installable but cannot be removed in the field.
Hubs: Single, removable, gasketless hub, cover plate or hub opening only. Hubs and cover plate are interchangeable.
GENERAL INFORMATION:
CONNECTIONS:
all HQ-4 all HQ-5 all HQ-5 all HQ-5
all HQ-7 all HQ-7
Product Schedule 430
34
Common Features
J 320A continuous duty rated
J Offset design for easier UG wiring
J Silver-brazed connections
J 100% rated lever bypass w/clamping action
on meter
J Factory installed lugs or 3/8” stud connection
J Steel or aluminum construction
J Glass-filled polyester block construction
J Track-resistant lexan shield
J Plated copper current path
TYPE HQSW/T 4-5 TERMINAL CLAMPING JAW LEVER BYPASS METER MOUNTING EQUIPMENT -- OFFSET STYLE
Consult the factory for other available options such as, but not
limited to alternate hasp material, aluminum enclosures, 5
terminal devices and special labeling.
48104-02
Cont.
Cover Amp Terminal Connector Dimensions (in.) Hub Barrel Lock No. of 5th Jaw Catalog Enclosure
Style Rating Service Line Load W H D Opening KO Prov. Term. Kit Number Material Type
Ringless 320 OH/UG 3/8-24 Stud 3/8-24 Stud 16.0 20.0 5.0 HD Cl. Plate N/A 4
H35815-5
44604-02 i Steel HQ4SW
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 16.0 20.0 5.0 HD Cl. Plate N/A 4
H35815-5
44604-82 ai Steel HQ4SW
Ringless 320 OH/UG 3/8-24 Stud 3/8-24 Stud 16.0 20.0 5.0 HD Opening N/A 5 Installed 44605-036 hi Steel HQ4SW
Ringless 320 UG 3/8-24 Stud 3/8-24 Stud 16.0 31.0 5.0 HD Cl. Plate N/A 4
H35815-5 48004-02RG
j Steel HQ4SW
Ringless 320 UG #4-600 kcmil (2) #4-350 kcmil 16.0 31.0 5.0 HD Cl. Plate N/A 4
H35815-5 48004-82
aj Steel HQ4SW
Ringless 320 UG #4-600 kcmil (2) #4-350 kcmil 16.0 31.0 5.0 HD Cl. Plate N/A 5 Installed 48005-82aj Steel HQ4SW
Ringless 320 OH/UG 3/8-24 Stud 3/8-24 Stud 16.0 31.0 5.0 HD Cl. Plate N/A 4
H35815-5
48104-02 h Steel HQ4SWT
Ringless 320 OH/UG #4-600 kcmil (2) #4-350 kcmil 16.0 31.0 5.0 HD Cl. Plate N/A 4
H35815-5
48104-82 b Steel HQ4SWT
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 16.0 31.0 5.0 3” Hub Inst. N/A 4
H35815-5
48144-82 a Steel HQ4SWT
Ringless 320 OH/UG 3/8-24 Stud 3/8-24 Stud 16.0 31.0 5.0 HD Cl. Plate N/A 5 Installed 48105-02FL h Steel HQ5SWT
Ringless 320 OH/UG #4-600 kcmil (2) #4-350 kcmil 16.0 31.0 5.0 HD Cl. Plate 7/8” 4
H35815-5
48104-82BP b Steel HQ4SWT
Ringless 320 OH/UG 3/8-24 Stud 3/8-24 Stud 16.0 31.0 5.0 HD Cl. Plate N/A 4
H35815-5
48104-82WI Steel HQ4SWT
Ringless 320 OH/UG #6-350 kcmil (2) #4-350 kcmil 16.0 31.0 5.0 HD Cl. Plate N/A 4
H35815-5
48104-8201 dh Steel HQ4SWT
Ringless 320 OH/UG (2) #4-350 kcmil (2) #4-350 kcmil 16.0 31.0 5.0 HD Cl. Plate N/A 4
H35815-5
48104-8203 eh Steel HQ4SWT
Ringless 320 OH/UG (2) #4-350 kcmil (2) #4-350 kcmil 16.0 31.0 5.0 HD Cl. Plate N/A 4
H35815-5
48104-8263 fh Steel HQ4SWT
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 16.0 31.0 5.0 HD Cl. Plate 7/8” 5 Installed 48105-83BU a Steel HQ5SWT
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 16.0 31.0 5.0 HD Cl. Plate N/A 4
H35815-5
48104-82TS ac Steel HQ4SWT
Ringless 320 OH/UG #4-600 kcmil (2) #4-500 kcmil 16.0 31.0 5.0 HD Cl. Plate N/A 4
H35815-5
48104-82TX gh Steel HQ4SWT
a 60162 lugs are also rated for (2) 2/0-250 kcmil.
b 60162 line lugs, 56732 load side lugs.
c Anti-inversion clip, 59676D, included.
d 58490-1 line lugs and 56732-2 load lugs, 13/32”
opening on lugs.
e 56732-2 line and load lugs (13/32” opening).
f 56732 line and load lugs (9/16” opening).
g 60162 line lugs and 56732M load lugs.
h Ground lug included.
i HQSW (446 prefix) are not UL listed for OH applications.
j 480XX Series - UG only - meter moved up in device.
KNOCKOUTS (inches):
AC: 1/4, 1/2
EE: 2, 2-1/2, 3
HD: x4.281 HUB 0P
RX: x2.750 HUB 0P
Anti-Inversion
Wire Insert
(optional)
#H59676
Product Schedule 431
35
Capacity: 320 ampere continuous, 400 ampere maximum, when wired to National Electrical Code ampacity; 600 volts.
Application: Single phase, 3 wire.
Enclosures: Constructed of 14 gauge galvanized steel with polyester powder finish. All enclosures are NEMA type 3R.
Block Assembly: Glass fiber reinforced polyester plastic. High strength arc and track resistant.
Bypass: Lever-operated jaw release. Moving lever up closes bypass and unclamps meter. Meter blade to jaw terminal arcing is
eliminated. The cover cannot be replaced with lever in bypass position. Bypass capacity: 320 ampere continuous.
Terminals: 3/8” - 24 cold-headed zinc-plated steel studs with nuts and captive Belleville washers to accommodate various pressure type
lugs. Supplied with or without lugs.
Lugs: Connection lugs are available for use with these mounting devices. Recommended lugs are type #60162, which handle a single
conductor up to 600 MCM or two conductors up to 250 MCM. 6 lugs are required.
UL: Type HQ-4SWT mounting devices are listed by UL for use on loads up to 320 ampere continuous, 600 volts a.c. HQ4SW devices
are not listed.
Safety Shield: Track resistant transparent polycarbonate insulating safety shield and fiber insulating barriers provide protection from accidental
shorts and shocks.
Anti-Inversion An optional wire-type jaw insert (#H59676) can be used with HQ-4S to prevent inverted installation of Talon Class 320
Insert: single phase meters. The insert rejects normal width terminal blades, yet admits the Talon Class 320 narrower upper
right-hand blade. The insert is field-installable but cannot be removed in the field.
Hubs: Single, removable, gasketless hub, cover plate or no hub. Hubs and cover plate are interchangeable.
GENERAL INFORMATION:
CONNECTIONS:
Type HQ-4SW, HQ-4SWT
Product Schedule 431
36
Common Features
J 320A continuous duty rated
J Silver-brazed connections
J 100% rated lever bypass w/clamping action
on meter
J Factory installed lugs or 1/2” stud connection
J Steel or aluminum construction
J Heavy duty glass-filled polyester block construction
J Track-resistant lexan shield
J Plated copper current path
TYPE HQD 4-7 TERMINAL CLAMPING JAW LEVER BYPASS METER MOUNTING EQUIPMENT
Cont.
Cover Amp Terminal Connector Dimensions (in.) Hub Barrel Lock No. of 5th Jaw Catalog Enclosure
Style Rating Service Line Load W H D Opening KO Prov. Term. Kit Number Material Type
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 HD Opening N/A 4
H35815-2
47704-01 Steel HQ4D
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 HD Opening N/A 4
H35815-2
47704-01FL Steel HQ4D
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 HD Opening 7/16” 4
H35815-2
47704-01NU Steel HQ4D
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 HD Cl. Plate N/A 4
H35815-2
47704-02 Steel HQ4D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 HD Cl. Plate N/A 4
H35815-2
47704-82 a Steel HQ4D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 2.5” Hub Inst. N/A 4
H35815-2
47734-82 a Steel HQ4D
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 3” Hub Inst. N/A 4
H35815-2
47744-02 Steel HQ4D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 3” Hub Inst. N/A 4
H35815-2
47744-82 a Steel HQ4D
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 HD Opening N/A 5 Installed 47705-01FL be Steel HQ5D
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 HD Cl. Plate N/A 5 Installed 47705-02 be Steel HQ5D
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 HD Cl. Plate N/A 5 Installed 47705-02FL Steel HQ5D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 HD Opening N/A 5 Installed 47705-81 abe Steel HQ5D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 HD Cl. Plate N/A 5 Installed 47705-82 abe Steel HQ5D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 HD Cl. Plate N/A 5 Installed 47705-826 abc Steel HQ5D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 3” Hub Inst. N/A 5 Installed 47745-826 abc Steel HQ5D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 3.5” Hub Inst. N/A 5 Installed 47755-82 ab Steel HQ5D
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 HD Opening N/A 7 N/A 47707-01 Steel HQ7D
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 HD Opening N/A 7 N/A 47707-01FL Steel HQ7D
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 HD Opening 7/16” 7 N/A 47707-01NU Steel HQ7D
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 HD Cl. Plate N/A 7 N/A 47707-02 e Steel HQ7D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 HD Cl. Plate N/A 7 N/A 47707-82 a Steel HQ7D
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 14.0 28.0 6.0 3” Hub Inst. N/A 7 N/A 47747-02 Steel HQ7D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 HD Opening N/A 7 N/A 47707-81TH Steel HQ7D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 HD Cl. Plate N/A 7 N/A 47707-82TH Steel HQ7D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 3” Hub Inst . N/A 7 N/A 47747-82 a Steel HQ7D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 3.5” Hub Inst. N/A 7 N/A 47757-826 ac Steel HQ7D
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 14.0 28.0 6.0 4” Hub Inst. N/A 7 N/A 47767-826 ac Steel HQ7D
Ringless 320 OH/UG #4-600 kcmil (2) #4-350 kcmil 14.0 28.0 6.0 HD Cl. Plate N/A 7 N/A 9804-9082 ad Steel HQ7D
a 60162 lugs are also rated for (2) 2/0-250 kcmil.
b 5th jaw at 6:00 position.
Consult the factory for other available options such
as, but not limited to alternate hasp material,
aluminum enclosures and special labeling.
KNOCKOUTS (inches):
AE: 1/4,1/2, 3/4, 1, 1-1/4
GG: 2-1/2, 3, 3-1/2
HH: 2-1/2, 3, 3-1/2, 4
HD: x4.281 HUB 0P
47707-02
c Ground lug included.
d 60162 line side lugs, 56732 load side lugs.
e Can be used 3-Ph 3-W application.
Anti-Inversion
Wire Insert
(optional)
#H59676
Product Schedule 435
37
Capacity: 320 ampere continuous, 400 ampere maximum, when wired to National Electrical Code ampacity: 600 volts.
Application: HQ-4D: 1 phase, 3 wire; HQ-5D: 1, or 3 phase, 3 wire grounded or ungrounded; HQ-7D: 3 phase, 4 wire wye or 4 wire delta.
Enclosures: Constructed of 14 gauge galvannealed steel with polyester powder finish. Also available in 28” H x 16” W aluminum box or in
31-1/2” H x 18” W steel box upon request. When ordering specify “same as Cat. # 477xx-xx except...” All boxes have ringless
cover. All enclosures are NEMA type 3R.
Block Assembly: Glass fiber reinforced polyester plastic. High strength arc and track resistant.
Bypass: Lever-operated jaw release. Moving lever up closes bypass and unclamps meter. Meter blade to jaw terminal arcing is
eliminated. The cover cannot be replaced with lever in bypassed position. Bypass capacity: 320 ampere continuous.
Terminals: 1/2” cold-headed zinc-plated steel studs with nuts and captive Belleville washers to accommodate various pressure type lugs.
Supplied without lugs.
Lugs: Connection lugs are available for use with these mounting devices. Recommended lugs are type #60162, which handle single
conductor up to 600 MCM or two conductors up to 250 MCM.
UL: HQ-4D, HQ-5D and HQ-7D mounting devices are listed by UL for use on loads up to 320 ampere continuous, 600 volts a.c.
Safety Shield: Track resistant transparent polycarbonate insulating safety shield and fiber insulating barriers provide protection from accidental
shorts and shocks.
Anti-Inversion An optional wire-type jaw insert (#H59676) can be used with HQ-4S to prevent inverted installation of Talon Class 320
Insert: single phase meters. The insert rejects normal width terminal blades, yet admits the Talon Class 320 narrower upper
right-hand blade. The insert is field-installable but cannot be removed in the field.
Hubs: Single, removable, gasketless hub, cover plate or no hub. Hubs and cover plate are interchangeable.
GENERAL INFORMATION:
--
CONNECTIONS:
HQ-4D HQ-5D HQ-7D HQ-7D
Product Schedule 435
38
Common Features
J Narrow enclosure design
J 320A continuous duty rated
J Silver-brazed connections
J 100% rated lever bypass w/clamping action on meter
J Factory installed lugs or stud connection
J Steel or aluminum construction
J Glass-filled polyester block construction
J Track-resistant lexan shield
J Plated copper current path
TYPE HQD/F 4-7 TERMINAL CLAMPING JAW LEVER BYPASS METER MOUNTING EQUIPMENT
a 60162 lugs are also rated for (2) 2/0-250 kcmil.
b Lugs are included, not installed.
c 56732 line and load lugs.
Consult the factory for other available options such as, but not limited to alternate hasp
material, aluminum enclosures, alternate 5 terminal devices and special labeling.
KNOCKOUTS (inches):
B: 1/2, 3/4
HH: 2-1/2, 3, 3-1/2, 4
HD: x4.281 HUB 0P
41704-01
d Ground lug included.
e 5th terminal in 6:00 position.
f Meter offset - no bussing
g Can be used for 3-Ph 3-W applications.
Cont.
Amp Terminal Connector Dimensions (in.) Hub No. of 5th Jaw Catalog Numbers
Rating Service Line Load W H D Opening Term. Kit Steel Aluminum Type
320 OH/UG 3/8”-24 stud 3/8”-24 stud 15.8 20.0 6.0 HD Opening 5 Installed - 41105-02FL HQS
320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 15.8 20.0 6.0 HD Opening 4 H35815-2 - 41704-01 HQDF
320 OH/UG #4-600 kcmil #4-600 kcmil 15.8 20.0 6.0 HD Opening 7 N/A - 41707-8108 a HQDF
320 OH/UG (2) #4-350 kcmil (2) #4-350 kcmil 15.8 20.0 6.0 HD Cl. Plate 7 N/A - 41707-826 cd HQDF
320 OH/UG #4-600 kcmil #4-600 kcmil 15.8 20.0 6.0 3” Hub Incl. 7 N/A - 41747-8268 ab HQDF
320 OH/UG #4-600 kcmil #4-600 kcmil 15.8 20.0 6.0 3.5” Hub Inst. 7 N/A - 41757-8208 ab HQDF
320 OH/UG 3/8”-24 stud 3/8”-24 stud 20.0 34.0 6.0 HD Opening 7 N/A 40107-02DU - HQSf
320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 HD Cl. Plate 5 Installed 49005-02FL deg 49105-02FL deg HQDB
320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 HD Cl. Plate 7 N/A 49007-02FL d 49107-02FL d HQDB
Product Schedule 436
39
Capacity: 320 ampere continuous, 400 ampere maximum, when wired to National Electrical Code ampacity: 600 volts.
Application: HQ-4D: 1 phase, 3 wire; HQ-5D: 1, 2, or 3 phase, 3 wire grounded or ungrounded; HQ-7D: 3 phase, 4 wire wye or 4 wire delta.
Enclosures: Constructed of 14 gauge galvannealed steel with polyester powder finish. Also available in 28” H x 16” W aluminum box or in
31-1/2” H x 18” W steel box upon request. When ordering specify “same as Cat. # 477xx-xx except...” All boxes have ringless
cover. All enclosures are NEMA type 3R.
Block Assembly: Glass fiber reinforced polyester plastic. High strength arc and track resistant.
Bypass: Lever-operated jaw release. Moving lever up closes bypass and unclamps meter. Meter blade to jaw terminal arcing is
eliminated. The cover cannot be replaced with lever in bypassed position. Bypass capacity: 320 ampere continuous.
Terminals: 1/2” cold-headed zinc-plated steel studs with nuts and captive Belleville washers to accommodate various pressure type lugs.
Supplied without lugs.
Lugs: Connection lugs are available for use with these mounting devices. Recommended lugs are type #60162, which handle single
conductor up to 600 MCM or two conductors up to 250 MCM.
UL: HQ-4D, HQ-5D and HQ-7D mounting devices are listed by UL for use on loads up to 320 ampere continuous, 600 volts a.c.
Safety Shield: Track resistant transparent polycarbonate insulating safety shield and fiber insulating barriers provide protection from accidental
shorts and shocks.
Anti-Inversion A wire-type jaw insert (#59676) can be used with HQ-4D to prevent inverted installation of Type MS-E single phase meters.
Insert: The insert rejects normal width terminal blades, yet admits the MS-E’s narrower upper right-hand blade. The insert is
field-installable but cannot be removed in the field.
Hubs: Single, removable, gasketless hub, cover plate or no hub. Hubs and cover plate are interchangeable.
GENERAL INFORMATION:
Product Schedule 436
40
Common Features
J Large enclosure
J 320A continuous duty rated
J Offset design for easier UG wiring - also OH rated
J Silver-brazed connections
J 100% rated lever bypass w/clamping action
on meter
J Factory installed lugs or 3/8” stud connection
J Steel or aluminum construction
J Glass-filled polyester block construction
J Track-resistant lexan shield
J Plated copper current path
J 1/2” or 3/8” stud models available
TYPE HQDSW/SWD 4-7 TERMINAL CLAMPING JAW LEVER BYPASS METER MOUNTING EQUIPMENT
Cont.
Cover Amp Terminal Connector Dimensions (in.) Hub Barrel Lock No. of 5th Jaw Catalog Enclosure
Style Rating Service Line Load W H D Opening KO Prov. Term. Kit Number Material Type
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 HD Opening N/A 4
H35815-5
44704-01 Steel HQ4DSW
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 HD Opening 7/16” 4
H35815-5
44704-01NU Steel HQ4DSW
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 HD Cl. Plate N/A 4
H35815-5
44704-02 Steel HQ4DSW
Ringless 320 OH/UG #4-600 kcmil 1/2”-20 Stud 20.0 34.0 6.0 HD Cl. Plate N/A 4
H35815-5
44704-82 d Steel HQ4DSW
Ringless 320 OH/UG 3/0-800 kcmil 3/8”-24 Stud 20.0 34.0 6.0 HD Cl. Plate 7/8” 4
H35815-5
44704-82PP Steel HQ4DSW
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 20.0 34.0 6.0 HD Cl. Plate N/A 4
H35815-5
44704-8265 ach Steel HQ4DSW
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 HD Cl. Plate N/A 5 Installed 44705-02 i Steel HQ5DSW
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 HD Opening N/A 7 N/A 44707-01 Steel HQ7DSW
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 HD Opening 7/16” 7 N/A 44707-01NU Steel HQ7DSW
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 HD Cl. Plate N/A 7 N/A 44707-02 Steel HQ7DSW
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 HD Cl. Plate N/A 7 N/A 44707-02FL Steel HQ7DSW
Ringless 320 OH/UG 3/0-800 kcmil 1/2”-20 Stud 20.0 34.0 6.0 HD Cl. Plate N/A 7 N/A 44707-02PP Steel HQ5SWD
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 20.0 34.0 6.0 HD Cl. Plate N/A 7 N/A 44707-826 ah Steel HQ7DSW
Ringless 320 OH/UG #4-600 kcmil (2) #4-350 kcmil 20.0 34.0 6.0 HD Cl. Plate N/A 7 N/A 44707-82TX b Steel HQ7DSW
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 3” Hub Inst. N/A 4
H35815-5
44744-02 Steel HQ4DSW
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 3” Hub Inst. N/A 7 N/A 44747-02 Steel HQ7DSW
Ringless 320 OH/UG 1/2”-20 Stud 1/2”-20 Stud 20.0 34.0 6.0 3.5” Hub Inst. N/A 4
H35815-5
44754-02 Steel HQ4DSW
Ringless 320 UG #4-600 kcmil (2) #2-500 kcmil 20.0 34.0 6.0 HD Cl. Plate N/A 4
H35815-5
47404-82 cefh Steel HQ4SWD
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 20.0 34.0 6.0 HD Cl. Plate 7/8” 4
H35815-5
48704-02 Steel HQ4SWD
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 20.0 34.0 6.0 HD Cl. Plate 7/8” 4
H35815-5
48704-82GP ach Steel HQ4SWD
Ringless 320 OH/UG #4-600 kcmil (2) #2-500 kcmil 20.0 34.0 6.0 HD Cl. Plate N/A 4
H35815-5
48704-82GU ceh Steel HQ4SWD
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 20.0 34.0 6.0 HD Cl. Plate 7/8” 5 Installed 48705-02FE Steel HQ5SWD
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 20.0 34.0 6.0 HD Cl. Plate N/A 5 Installed 48705-08 Steel HQ5SWD
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 20.0 34.0 6.0 HD Cl. Plate 7/8” 7 N/A 48707-02 Steel HQ7SWD
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 20.0 34.0 6.0 HD Cl. Plate 7/16” 7 N/A 48707-029 Steel HQ7SWD
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 20.0 34.0 6.0 HD Cl. Plate N/A 7 N/A 48707-02FE Steel HQ7SWD
Ringless 320 OH/UG (2)#4-350kcmil (2)#6-250kcmil 20.0 34.0 6.0 HD Cl. Plate N/A 7 N/A 48707-82 Steel HQ7SWD
Ringless 320 OH/UG #4-600 kcmil #4-600 kcmil 20.0 34.0 6.0 HD Cl. Plate 7/8” 7 N/A 48707-82GP ach Steel HQ7SWD
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 20.0 34.0 6.0 HD Cl. Plate 7/16” 5 Installed 9804-9146 g Steel HQ5SD
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 20.0 34.0 6.0 HD Cl. Plate 7/16” 7 N/A 9804-9147 g Steel HQ7SD
Ringless 320 OH/UG 3/8”-24 Stud 3/8”-24 Stud 20.0 34.0 6.0 HD Cl. Plate N/A 7 N/A 47407-02 Steel HQ7SWD
Ringless 320 OH/UG (2)#4-350 kcmil (2)#4-350 kcmil 20.0 34.0 6.0 HD Cl. Plate 7/8” 4
H35815-5
48704-82 Steel HQ4SWD
a 60162 lugs are also rated for (2) 2/0-250 kcmil.
b 60162 line lugs, 56732-1 load side lugs.
Consult the factory for other available options such
as, but not limited to alternate hasp material,
aluminum enclosures, alternate 5 terminal devices
and special labeling.
48707-82GP
c Anti-inversion clip, 59676D, included.
d 56476 line lugs, 60162 line neutral lug.
e 60162 line lugs, 56490 load lugs.
f UG only - interior moved up.
KNOCKOUTS (inches):
B: 1/2, 3/4
HH: 2-1/2, 3, 3-1/2, 4
HD: x4.281 HUB 0P
Anti-Inversion
Wire Insert
(optional)
#H59676
g Offset design - no bussing. HQS block.
h Ground lug included.
i Can be used for 3-Ph 3-W applications.
Product Schedule 437
41
Capacity: 320 ampere continuous, 400 ampere maximum, when wired to National Electrical Code ampacity; 600 volts.
Application: HQ-4D/SW: 1 phase, 3 wire; HQ-5D/SW: 1, 2 or 3 phase, 3 wire grounded or ungrounded: HQ-7D/SW: 3 phase, 4 wire wye or delta.
Enclosures: Constructed of 14 gauge galvannealed steel with polyester powder finish. All boxes have a ringless cover.
All enclosures are NEMA type 3R.
Bypass: Lever-operated jaw release. Moving lever up closes bypass and unclamps meter blades. Meter blade to jaw terminal arcing is
eliminated. The cover cannot be replaced with lever in bypassed position. Bypass capacity: 320 ampere continuous.
Terminals: 3/8” or 1/2” cold-headed zinc-plated steel studs with nuts and captive Belleville washers to accommodate various pressure type
lugs. Supplied without lugs unless otherwise indicated.
Lugs: Connection lugs are available for use with these mounting devices.
UL: HQ-4D/SW, HQ-5D/SW and HQ-7D/SW mounting devices are listed by UL for use on underground feed services with loads up to
320 amps continuous, 600 volts a.c. Units supplied with hubs are not UL labeled..
Safety Shield: Track resistant transparent polycarbonate insulating safety shield and insulating barriers provides protection from accidental
shorts and shocks.
Anti-Inversion An optional wire-type jaw insert (#H59676) can be used with HQ-4S to prevent inverted installation of Talon Class 320
Insert: single phase meters. The insert rejects normal width terminal blades, yet admits the Talon Class 320 narrower upper
right-hand blade. The insert is field-installable but cannot be removed in the field.
GENERAL INFORMATION:
CONNECTIONS:
HQ-4D/SW HQ-5D/SW HQ-7D/SW
Product Schedule 437
42
Common Features
J 400A and 480A continuous duty models available
J Heavy duty construction using 1/2” plated bolts
J Rake-type bypass available
J Factory installed lugs or 1/2” stud connection
Cont.
Amp Terminal Connector Dimensions (in.) Hub Catalog Encl.
Rating Line Load Neutral W H D Opening Number Material Bypass Type
400 OH/UG (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil 13.8 26.0 6.0 3” Hub Inst. 9809-8239 ab Steel H56495 K4 - non UL
(56427-M) (56425-M) (56490)
400 OH/UG (2) #6-350 kcmil (2) #6-350 kcmil (4) #6-350 kcmil 13.8 26.0 6.0 HD Cl. Plate 9809-8244 a Steel H56495 K4 - non UL
(56425) (56425) (56426)
400 OH/UG (2) #6-350 kcmil (2) #6-350 kcmil (4) #6-350 kcmil 13.8 26.0 6.0 3” Hub Inst. 9809-8205 a Steel H56495 K4 - non UL
(56427) (56425) (56426)
400 OH/UG (2) #6-350 kcmil (2) #6-350 kcmil (4) #6-350 kcmil 13.8 26.0 6.0 3” Hub Inst. 9809-8214 ad Steel H56495 K4 - non UL
(56427) (56425) (56426)
400 UG (2) #6-350 kcmil (2) #6-350 kcmil (4) #6-350 kcmil 13.8 26.0 6.0 Blank Top 9809-8200 a Steel H56495 K4 - non UL
(56427) (56425) (56426)
400 OH/UG (2) #6-350 kcmil (2) #6-350 kcmil (4) #6-350 kcmil 13.8 26.0 6.0 HD Cl. Plate 9809-8203 a Steel H56495 K4 - non UL
(56427) (56425) (56426)
400 OH/UG (2) #6-350 kcmil (2) #6-350 kcmil (4) #6-350 kcmil 13.8 26.0 6.0 HD Cl. Plate 9809-8212 ae Steel H56495 K4 - non UL
(56427) (56425) (56426)
400 OH/UG (2) #6-350 kcmil (2) #6-350 kcmil (4) #6-350 kcmil 13.8 26.0 6.0 HD Cl. Plate 9809-8461 a Steel H56495 K4 - non UL
(56427) (56425) (56426)
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 13.8 26.0 6.0 (2) 2” Hubs Inst. 9809-8436 Steel H56495 K4 - non UL
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 13.8 26.0 6.0 3” Hub Inst. 9809-8417 Steel H56495 K4 - non UL
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 13.8 26.0 6.0 3.5” Hub Inst. 9809-8455 i Steel H56495 K4 - non UL
400 UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 13.8 26.0 6.0 Blank Top 9809-8414 Steel H56495 K4 - non UL
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 13.8 26.0 6.0 HD Cl. Plate 9809-8416 Steel H56495 K4 - non UL
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 13.8 26.0 6.0 HD Cl. Plate 9809-8438 Steel H56495 K4 - non UL
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 13.8 26.0 6.0 HD Cl. Plate 9809-8459 h Steel H56495 K4 - non UL
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 13.8 26.0 6.0 HD Cl. Plate 9809-8507 fg Steel H56495 K4 - non UL
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 13.8 26.0 6.0 HD Opening 9809-8236 ac Steel H56495 K4 - non UL
400 OH/UG 3/0-800 kcmil 3/0-800 kcmil 3/0-800 kcmil 13.8 26.0 6.0 3” Hub Inst. 9809-8206 a Steel H56495 K4 - non UL
(56733) (56477) (56476)
400 UG 3/0-800 kcmil 3/0-800 kcmil 3/0-800 kcmil 13.8 26.0 6.0 Blank Top 9809-8449 a Steel H56495 K4 - non UL
(56733) (56477) (56476)
400 UG 3/0-800 kcmil (2) #6-350 kcmil (4) #6-350 kcmil 13.8 26.0 6.0 Blank Top 9809-8460 a Steel H56495 K4 - non UL
(56733) (56425) (56426)
400 OH/UG 3/0-800 kcmil 3/0-800 kcmil 3/0-800 kcmil 13.8 26.0 6.0 HD Cl. Plate 9809-8204 a Steel H56495 K4 - non UL
(56733) (56477) (56476)
400 OH/UG 3/0-800 kcmil 3/0-800 kcmil 3/0-800 kcmil 13.8 26.0 6.0 HD Cl. Plate 9809-8213 ae Steel H56495 K4 - non UL
(56733) (56477) (56476)
400 OH/UG 3/0-800 kcmil (2) #6-350 kcmil (4) #6-350 kcmil 13.8 26.0 6.0 HD Opening 9809-8462 ad Steel H56495 K4 - non UL
(56733) (56425) (56426)
a Ground lug included.
b Closure plate included.
c Device has neutral bar in place of stud.
9809-8507
d Special K.O. config. Back K.O. 2, 2, 5, 3.
e Special K.O. config. Back K.O. 2, 5, 3, 3, 5.
f Special K.O. config. No K.O.s on side or back.
J Steel or aluminum construction
J Polycarbonate safety shield available
J Non-UL listed units (due to wire bend)
J Plated copper current path
g Lug extender installed - line side.
h Cover includes hazardous voltage label.
i “Residential Use” ink stamp.
Consult the factory for other available options such as, but not limited to alternate hasp material,
aluminum enclosures and special labeling.
TYPE K4 400/480A BOLT-IN METER MOUNTING EQUIPMENT
Product Schedule 440
43
Capacity: 400 amperes continuous - 300 volts a.c.
Application: For use with 3 wire single phase self-contained Type MS-K watt/hour meters.
Enclosures: Constructed of 14 gauge galvannealed steel suitable for indoor or outdoor installations. All enclosures are NEMA type 3R.
Bypass: Separate manual type #H56495.
Terminals: 1/2” - 20 steel studs with nuts and captive Belleville washers to accommodate various pressure-type lugs for conductors from
#6 to 800 KCMIL.
Blocks: Glass fiber reinforced polyester plastic. High strength arc and track resistant.
Meter Two position stud type. One set of studs provides out-of-service storage. The in-service studs are positioned so the meter
Mounting: Cannot be installed upside-down.
UL: Devices on this schedule are not UL listed due to wire bend requirements.
GENERAL INFORMATION:
KNOCKOUT DIAGRAM: a
CONNECTIONS:
KNOCKOUTS (inches):
B: 1/2, 3/4
GG: 2-1/2, 3, 3-1/2
HH: 2-1/2, 3, 3-1/2, 4
HD: x4.281 HUB 0P
a See notes for exceptions.
TORQUE DATA:
Connection Part No. Stud Size Wrench Size Torque
Lug Mounting H56271 1/2” - 20 3/4” Hex 500 in-lbs.
Nut/Washer
Meter Mounting 56271-2 5/16” - 24 1/2” Hex 150 in-lbs.
Nut/Washer
Lug Wire - - 5/16” Allen 275 in-lbs.
Binding Screws 3/8” Allen 375 in-lbs.
1/2” Allen 500 in-lbs.
K-Base Torque Specifications
NUT WITH
BELLEVILLE
WASHER
FLAT
WASHER
Install Flat Washer On Top
Of Connector Lug
Product Schedule 440
K4U
Connectors for single conductor per terminal Connectors for two conductors per terminal
Lug H56733 (2 req.)
(250-800 MCM)
Lug H56476 (2 req.)
(250-800 MCM)
Lug H56477 (2 req.)
(250-800 MCM)
Ground Lug
Included
Overhead
Service
Underground
Service
44
Common Features
J 400A and 480A continuous duty models
available
J Heavy duty construction using 1/2” plated bolts
J Rake-type bypass available
J Factory installed lugs or 1/2” stud connection
J Steel or aluminum construction
J Polycarbonate safety shield available
J UL listed for top and bottom feed
J Plated copper current path
TYPE K4UT 400/480A BOLT-IN METER MOUNTING EQUIPMENT
Cont.
Amp Terminal Connector Dimensions (inches) Hub Catalog Enclosure
Rating Service Line Load Neutral W H D Opening Number Material Bypassg Type
400 OH/UG (2) #6-350 kcmil (2) #6-350 kcmil (4) #6-350 kcmil 17.8 36.0 6.0 HD Cl. Plate 9810-8502 d Steel H56495 K4UT
(56427) (56425) (56426)
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 17.8 36.0 6.0 HD Cl. Plate 9810-8507 d Steel H56495 K4UT
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 17.8 36.0 6.0 HD Cl. Plate 9810-8521 ef Steel H56495 K4UT
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud (2) 1/2”-20 Stud 17.8 36.0 6.0 HD Cl. Plate 9810-8523 bd Steel H56495 K4UT
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 17.8 36.0 6.0 HD Cl. Plate 9810-8526 ae Steel H56495 K4UT
400 OH/UG (2) #2-500 kcmil (2) #2-500 kcmil (2) #2-500 kcmil 17.8 36.0 6.0 HD Cl. Plate 9810-8527 bde Steel H56495 K4UT
(56427-M) (56425-M) (56490)
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud (2) 1/2”-20 Stud 17.8 36.0 6.0 HD Cl. Plate 9810-8528 abc Steel H56495 K4UT
400 OH/UG (2) #2-500 kcmil (2) #2-500 kcmil (2) #2-500 kcmil 17.8 36.0 6.0 HD Cl. Plate 9810-8542 bd Ptd. H56495 K4UT
(56427-M) (56425-M) (56490) Aluminum
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 17.8 36.0 6.0 3.5” Hub Inst. 9810-8545 Steel H56495 K4UT
400 OH/UG 3/0-800 kcmil 3/0-800 kcmil 3/0-800 kcmil 17.8 36.0 6.0 HD Cl. Plate N9810-8517 Steel H56495 K4UT
(56733) (56477) (56476)
480 OH/UG (2) #2-500 kcmil (2) #2-500 kcmil (2) #2-500 kcmil 17.8 36.0 6.0 (2) HD Cl. Plates 9810-9502 d Steel H56495 K4UT
(56427-M) (56425-M) (56490)
480 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 17.8 36.0 6.0 (2) HD Cl. Plates 9810-9507 d Steel H56495 K4UT
480 OH/UG (2) #2-500 kcmil (2) #2-500 kcmil (2) #2-500 kcmil 17.8 36.0 6.0 (2) HD Cl. Plates 9810-9542 bd Ptd. H56495 K4UT
(56427-M) (56425-M) (56490) Aluminum
480 OH/UG (2) #2-500 kcmil (2) #2-500 kcmil (4) #6-350 kcmil 17.8 36.0 6.0 (2) HD Cl. Plates 9810-9546 d Steel H56495 K4UT
(56427-M) (56427-M) (56426)
480 OH/UG (3) #6-250 kcmil (3) #6-250 kcmil (4) #6-350 kcmil 17.8 36.0 6.0 (2) HD Cl. Plates 9810-9549 Ptd. H56495 K4UT
(67753-1) (67753-1) (56426) Aluminum
Consult the factory for other available options such as, but not limited to alternate hasp material,
aluminum enclosures and special labeling.
9810-8507
a 2 ground lugs included.
b Device has neutral bar with (2) studs.
c Lug extender (59299) installed on line side.
d Ground lug included.
e Safety shield installed.
f Includes 7/8” barrel lock K.O. and bracket
g Bypass not included.
KNOCKOUTS (inches):
: 1/4
B: 1/2, 3/4
GG: 2-1/2, 3, 3-1/2
HH: 2-1/2, 3, 3-1/2, 4
HD: x4.281 HUB 0P
Product Schedule 443
45
Capacity: 400 or 480 ampere continuous, 300 volts a.c.
Application: For use with 3 wire single phase.
Enclosures: Constructed of 14 gauge G90 steel suitable for indoor or outdoor installation. All enclosures are NEMA type 3R.
Bypass: Separate manual type #H56495.
Blocks: Glass fiber reinforced polyester plastic. High strength, arc and track resistant.
Terminals: 1/2” cold headed cadmium plated steel studs with nuts and captive Belleville washers to accommodate various pressure type
lugs for conductors from #6 to 800 KCMIL.
Hubs: No hub. 3”, 3-1/2”, 4” removable type.
UL: Type K-4UT devices are UL listed.
GENERAL INFORMATION:
TORQUE DATA:
Connection Part No. Stud Size Wrench Size Torque
Lug Mounting H56271 1/2” - 20 3/4” Hex 500 in-lbs.
Nut/Washer
Meter Mounting H56271-2 5/16” - 24 1/2” Hex 150 in-lbs.
Nut/Washer
Lug Wire - - 5/16” Allen 275 in-lbs.
Binding Screws 3/8” Allen 375 in-lbs.
1/2” Allen 500 in-lbs.
K-Base Torque Specifications
NUT WITH
BELLEVILLE
WASHER
FLAT
WASHER
Install Flat Washer On Top
Of Connector Lug
K-BASE BYPASSES:
K-4 Bypass #56495, 2 required. For use
when removing meter from K-4 mounting
device.
1. Loosen nuts “C” and “D” 4 full turns.
2. Place bypass under nuts, shorting
across from line to load side.
3. Tighten all nuts securely.
Product Schedule 443
K-4 Bypass H56495
CONNECTIONS:
Lug Group Option A
For two conductors/terminal
Optional Lugs
For two conductors/terminal
Lug H56426 (1 req.)
(#6-350 MCM)
Lug H56427 (2 req.)
(#6-350 MCM) Lug H56733 (2 req.)
(250-800 MCM)
Lug H56476 (2 req.)
(250-800 MCM)
Lug H56477 (2 req.)
(250-800 MCM)
Lug H56425 (2 req.)
(#6-350 MCM)
Ground Lug
Included
Ground Lug
Included
Group A
Overhead
Service
Overhead
Service
Underground
Service
Group A
Underground
Service
46
Common Features
J 400A and 480A continuous duty models
available
J Heavy duty construction using 1/2” plated bolts
J Rake-type bypass and rotary available
J Factory installed lugs or 1/2” stud connection
TYPE K7 400/600A BOLT-IN METER MOUNTING EQUIPMENT
Cont. Terminal Connector
Amp Phase Neutral Dimensions (in.) Hub Catalog Encl.
Rating Service Line Load Line Load W H D Opening Number Material Bypass Type
400 OH/UG (2)#6-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil 20.3 34.0 6.1 HD Cl. Plate 9817-8005 a Steel H58888 or K7
(58853) (56732) (56732) (56732) H69623
400 OH/UG (2)#6-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil 20.3 34.0 6.1 HD Cl. Plate 9817-8012 Steel H58888 or K7
(58853) (56732) (56732) (56732) H69623
400 OH/UG (2)#6-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil 20.3 34.0 6.1 HD Cl. Plate 9817-8013 a Steel H58888 or K7
(58853) (56732) (56732) (56732) H69623
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 34.0 6.1 HD Cl. Plate 9817-8029 Steel H58888 or K7
H69623
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 34.0 6.1 3.5” Hub Inst. 9817-8043 cd Steel H58888 or K7
H69623
400 OH/UG 3/0-800 kcmil (2) #4-350 kcmil 3/0-800 kcmil (2) #4-350 kcmil 20.3 34.0 6.1 HD Cl. Plate 9817-8052 Steel H58888 or K7
(58852) (56732) (56476) (56732) H69623
400 OH/UG 1/2”-20 Stud (2) #4-350 kcmil 3/0-800 kcmil 3/0-800 kcmil 20.3 34.0 6.1 HD Cl. Plate 9817-8053 a Steel H58888 or K7
(56732) (56476) (56476) H69623
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 34.0 6.1 HD Cl. Plate 9817-8069 a Steel H58888 or K7
H69623
400 OH/UG (2)#6-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil 20.3 34.0 6.1 HD Cl. Plate 9817-8113 af Steel H58888 or K5
(58853) (56732) (56732) (56732) 69623
400 OH/UG 3/0-800 kcmil 3/0-800 kcmil 3/0-800 kcmil 3/0-800 kcmil 20.3 34.0 6.1 HD Cl. Plate N9817-8015 a Steel H58888 or K7
(58852) (56476) (56476) (56476) 69623
400 OH/UG 3/0-800 kcmil 3/0-800 kcmil 3/0-800 kcmil 3/0-800 kcmil 20.3 34.0 6.1 3” Hub Inst. N9817-8023 ac Steel 58888 or K7
(56476) (56476) (56476) (56476) 69623
400 OH/UG (2) #4-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil 20.3 34.0 6.1 4” Hub Inst. N9817-8025 ac Steel 58888 or K7
(56732) (56732) (56732) (56732) 69623
400 OH/UG 3/0-800 kcmil 3/0-800 kcmil 3/0-800 kcmil 3/0-800 kcmil 20.3 34.0 6.1 4” Hub Inst. N9817-8027 ac Steel 58888 or K7
(56476) (56476) (56476) (56476) 69623
400 UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 34.0 6.1 HD Cl. Plate 9817-8031 Steel 58888 or K7
69623
400 UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 34.0 6.1 HD Cl. Plate 9817-8041 ae Steel 58888 or K7
69623
400 UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 34.0 6.1 HD Cl. Plate 9817-8045 ae Steel 58888 or K7
69623
400 UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 34.0 6.1 HD Cl. Plate 9817-8061 ag Steel 58888 or K7
69623
400 UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 34.0 6.1 HD Cl. Plate 9817-8062 ag Alum 58888 or K7
69623
a Ground lug included.
b Closure plate included.
c Special K.O. config.: 1 K.O. on bottom 2.5” - 4”.
Consult the factory for other available options such as, but
not limited to alternate hasp material, aluminum enclosures
and special labeling.
d “Residential Use” ink stamp.
e Installed jumper for center phase for UG use.
f 3 phase, 3 wire or 1 phase 3 wire applications only.
J Steel or aluminum construction
J Polycarbonate safety shield available
J Non-UL and UL listed units
J Plated copper current path
g Unit is UL listed for UG use only.
h Bypass not included.
Product Schedule 447
47
Capacity: 400 amperes continuous at 600 volts a.c.
Application: For use with self-contained Type MT-K watt/hour meters on 3 phase, 4 wire wye and 4 wire delta services.
Enclosures: Constructed of 14 gauge galvanized steel suitable for indoor or outdoor installations. Ringless cover. Aluminum enclosure
available. Consult factory. All enclosures are NEMA type 3R.
Bypass: Separate manual type (H58888). Three required, 400 ampere bypass capacity.
Blocks: Glass fiber reinforced polyester plastic. High strength, arc and track resistant.
Terminals: 1/2” - 20 plated steel studs with nuts and captive Belleville washers to accommodate various pressure type lugs for conductors
from #6 to 800 KCM Cu or Al. Use 3/4” insulated wrench to fasten connectors to block (#55598).
Meter Mounting: The meter is mounted on six studs using 5/16” - 24 studs with nuts with captive Belleville washers. The three upper studs are
positioned so that the meter cannot be installed upside down. Use 1/2” insulated wrench (#55585). Another set of studs
provides out-of-service storage. With the meter in this position the slide plate in the box cover can be reversed so the cover can
be reinstalled with the words “out of service” showing.
UL: Type K-7 and K-7T are UL listed.
GENERAL INFORMATION:
KNOCKOUT DIAGRAM: a
KNOCKOUTS (inches):
B: 1/2, 3/4
HH: 2-1/2, 3, 3-1/2, 4
HD: x4.281 HUB 0P
a See notes for specific KO changes
per catalog number.
TORQUE DATA:
Connection Part No. Stud Size Wrench Size Torque
Lug Mounting H56271 1/2” - 20 3/4” Hex 500 in-lbs.
Nut/Washer
Meter Mounting H56271-2 5/16” - 24 1/2” Hex 150 in-lbs.
Nut/Washer
Lug Wire - - 5/16” Allen 275 in-lbs.
Binding Screws 3/8” Allen 375 in-lbs.
1/2” Allen 500 in-lbs.
K-Base Torque Specifications
NUT WITH
BELLEVILLE
WASHER
FLAT
WASHER
Install Flat Washer On Top
Of Connector Lug
Product Schedule 447
CONNECTIONS:
Connectors for Single Conductor Per Terminal Connectors for Two Conductors Per Terminal
H65476 (8 req.)
(250-800 MCM) H58852 (3 req.)
(250-800 MCM) H56732 (8 req.)
(Two #4-350 MCM)
H58853 (3 req.)
(Two #6-350 MCM)
H56732 (5 req.)
(Two #4-350 MCM)
H56476 (5 req.)
(250-800 MCM)
Group L
Single 800 mcm max
Overhead
Service
Group M
Single 500 mcm max
Underground
Service
Group J
Parallel 350 mcm max
Overhead
Service
Group K
Parallel 350 mcm max
Underground
Service
Polyphase Type K7 Polyphase Type K7 Polyphase Type K7 Polyphase Type K7
Ground Lug
Included
Ground Lug
Included Ground Lug
Included
Ground Lug
Included
48
Common Features
J 400A and 480A continuous duty models available
J Heavy duty construction using 1/2” plated bolts
J Rake-type and rotary bypass available
J Factory installed lugs or 1/2” stud connection
J Steel or aluminum construction
J Polycarbonate safety shield available
J All units are UL listed
J Plated copper current path
TYPE K7T/K7SW 400/480A BOLT-IN METER MOUNTING EQUIPMENT
a Ground lug included.
b Polycarbonate safety shield installed.
c 7/8” barrel lock K.O. and bracket included.
d 2 hub openings-(1) 3.5” hub inst. and 1 CL plate inst.
e 5 terminal for 3 phase, 3 wire or 1 phase 3 wire
services only.
f Indicates what bypass, if any, is installed. If no
bypass use 69623 or 58888.
g Lug extender installed - line side.
h Cover includes hazardous voltage label.
i “Residential Use” ink stamp.
KNOCKOUTS (inches):
B: 1/2, 3/4
HH: 2-1/2, 3, 3-1/2, 4
HD: x4.281 HUB 0P
Cont. Terminal Connectors - See Note Below
Amp Phase Neutral Dimensions (in.) Hub Catalog Encl. Bypass
Rating Service Line Load Line Load W H D Opening Number Matl. f Type
480 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 (2) HD Cl. Pl. 9817-9404 ae Steel Not Incl. K5T
480 OH/UG (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil 20.3 43.1 6.1 (2) HD Cl. Pl. 9817-9405 ae Steel Not Incl. K5T
480 OH/UG (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil 20.3 43.1 6.1 (2) HD Cl. Pl. 9817-9406 ae Steel Not Incl. K5T
480 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 26.1 37.7 6.1 (2) HD Prov. 9817-9801 ab Steel Not Incl K7SW
480 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 26.1 37.7 6.1 (2) HD Cl. Pl. 9817-9802 abc Steel Not Incl. K7SW
480 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 26.1 37.7 6.1 (2) HD Cl. Pl. 9817-9803 a Steel 69623 K7SW
480 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 26.1 37.7 6.1 (2) HD Cl. Pl. 9817-9804 ab Steel Not Incl. K7SW
400 OH/UG (2) #4-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil 20.3 43.1 6.1 HD Opening 9817-8501 a Steel Not Incl. K7T
400 OH/UG (2) #4-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil 20.3 43.1 6.1 3” Hub Inst. 9817-8503 a Steel Not Incl. K7T
400 OH/UG (2)#6-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil (2) #4-350 kcmil 20.3 43.1 6.1HD Cl. Plate 9817-8507 a Steel Not Incl. K7T
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 HD Opening 9817-8511 a Steel Not Incl. K7T
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 HD Cl. Plate 9817-8512 a Steel Not Incl. K7T
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 HD Cl. Plate 9817-8526 bc Steel Not Incl. K7T
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 HD Cl. Plate 9817-8528 a Steel Not Incl. K7T
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 HD Cl. Plate 9817-8529 a Alum. Not Incl. K7T
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 HD Cl. Plate 9817-8532 ab Steel Not Incl. K7T
400 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 HD Cl. Plate 9817-8534 ac Steel Not Incl. K7T
480 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 (2) HD Cl. Pl. 9817-9504 a Steel Not Incl. K7T
480 OH/UG (2) #4-500 kcmil (2) #4-500 kcmil ((2) #4-500 kcmil (2) #4-500 kcmil 20.3 43.1 6.1 (2) HD Cl. Pl. 9817-9505 a Steel Not Incl. K7T
480 OH/UG (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil 20.3 43.1 6.1 (2) HD Cl. Pl. 9817-9506 a Steel Not Incl. K7T
480 OH/UG (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil 20.3 43.1 6.1 (2) 3.5” Hubs Inst.9817-9510 a Steel Not Incl. K7T
480 OH/UG (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil 20.3 43.1 6.1 (2) 4” Hubs Inst. 9817-9512 a Steel Not Incl. K7T
480 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 (2) HD Cl. Pl. 9817-9526 a Steel Not Incl. K7T
480 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 (2) HD Cl. Pl. 9817-9527 a Alum. Not Incl. K7T
480 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 (2) HD Cl. Pl. 9817-9562 ab Steel Not Incl. K7T
480 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 (2) HD Prov. 9817-9564 abc Steel Not Incl. K7T
480 OH/UG (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil 20.3 43.1 6.1 (2) HD Cl. Pl. 9817-9565 a Ptd.Al Not Incl. K7T
480 OH/UG (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil 20.3 43.1 6.1 (2) HD Cl. Pl. 9817-9566 ab Steel Not Incl. K7T
480 OH/UG 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 1/2”-20 Stud 20.3 43.1 6.1 (2) HD Cl. Pl. 9817-9569 a Steel 69623 K7T
480 OH/UG (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil (2) #4-500 kcmil 20.3 43.1 6.1 (1)3.5” Hub Inst. 9817-9570 ad Steel Not Incl. K7T
Consult the factory for other available options such as, but not limited
to alternate hasp material, aluminum enclosures and special labeling.
Note: All K7T and K7SW are U.L. listed for OH and UG use. Installed
lugs are intended for dedicated OH or UG applications. Please ensure
lug listing complies with application requirements. Remove lugs if
necessary to obtain proper configuration for needed application.
K7T
9817-9504
Product Schedule 448
49
Capacity: 400 amperes continuous, 480 amperes continuous/480 amperes maximum - 600 volts a.c.
Application: For use with 3 or 4 wire, single phase and polyphase self-contained, Type K watt/hour meters.
Enclosures: Constructed of 14 gauge galvannealed steel suitable for indoor or outdoor installations. Aluminum enclosures also available-
contact factory. All enclosures are NEMA type 3R.
Bypass: Separate manual type (2 required for K-5, 3 required for K-7) or rotating link. Both types have 100% bypass capacity.
Blocks: Glass fiber reinforced polyester plastic. High strength, arc and track resistant.
Terminals: 1/2” - 20 plated steel studs with nuts and captive Belleville washers to accommodate various pressure type lugs for conductors
from #6 to 800 MCM Cu or Al. Require 3/4” socket wrench.
Meter Mounting: Stud type 5/16 - 24. 1/2” wrench required. Studs are positioned so the meter cannot be installed upside down.
UL: Type K-7 and K-7T are UL listed except as restricted by NEC wire-bending requirements. Both types may be wired for under
ground feed using parallel conductors on the line side. Type K-7T may also be wired using overhead feed with parallel
conductors on the line side. All devices require parallel wiring on the load side for UL listing. Type K-7 devices are U.L. listed
for up to 600 amperes capacity when wired to NEC capacity.
GENERAL INFORMATION:
Ground Lug
(included)
H56427-M (2 Req.)
(Two #2 to 500 KCM)
H56732-M (4 Req.)
(Two #4 to 500 KCM)
UNDERGROUND
SERVICE
(GROUP P)
H56732-M (8 Req.)
(Two #4 to 500 KCM)
Ground Lug
(included)
OVERHEAD
SERVICE
(GROUP Q)
UNDERGROUND
SERVICE
(GROUP R)
H56427-M (3 Req.)
(Two #2 to 500 KCM)
Ground Lug
(included)
H56732-M (5 Req.)
(Two #4 to 500 KCM)
TORQUE DATA:
Connection Part No. Stud Size Wrench Size Torque
Lug Mounting H56271 1/2” - 20 3/4” Hex 500 in-lbs.
Nut/Washer
Meter Mounting H56271-2 5/16” - 24 1/2” Hex 150 in-lbs.
Nut/Washer
Lug Wire - - 5/16” Allen 275 in-lbs.
Binding Screws 3/8” Allen 375 in-lbs.
1/2” Allen 500 in-lbs.
K-Base Torque Specifications
Ground Lug
(included)
H56732-M (6 Req.)
(Two #4 to 500 KCM)
OVERHEAD
SERVICE
(GROUP N)
CONNECTIONS:
K-BASE BYPASSES:
Instructions for installing and operating K-7 rotating link bypass #69623
To install bypass:
1. Remove the 3 nuts “A” from the studs extending from the 3 bypass bars.
2. Assure that bypass feet are vertically positioned in relation to the bypass handle as shown and the 3 handle
screws are tight enough so that bypass feet do not turn.
3. Install bypass assembly with the handle screws toward the top edge of the bypass handle as shown. Slide the
3 bypass feet over the exposed studs, through the holes in the bypass feet.
4. Loosen the 3 handle screws approximately 1/8 turn using a small standard-tip screwdriver.
5. Re-install nuts “A” and tighten securely so that bypass feet are in the vertical, non-bypassed position.
To operate bypass:
1. Loosen the 3 nuts “A” located on the 3 bypass bars, 1 full turn.
2. Loosen the 3 nuts “B” located on the line side current connectors, 4 full turns.
3. Slide the bypass handle from right to left, until the curved slots in the bypass feet rest against the studs on
the current connectors.
4. Securely tighten all 6 nuts “A” and “B”, while ensuring the bypass feet remain resting against the connector studs.
CURRENT CONNECTIONS
BYPASS FOOT
(3) TYPE.
HANDLE SCREW
(3) TYPE. BYPASS HANDLE
K-7 Block Assembly
BYPASS BAR (3) TYPE
A
A
A
K-7 Bypass #58888
K-7 Bypass #58888, 3 required. For use
when removing meter from K-7 mounting
device.
1. Loosen nuts “A” and “B” 4 full turns.
2. Place bypass under nuts, shorting
across from current connectors to
bypass bars.
3. Tighten all nuts securely.
NUT WITH
BELLEVILLE
WASHER
FLAT
WASHER
Install Flat Washer On Top
Of Connector Lug
Product Schedule 448
K-7 Bypass #H58888
50
Terminal Connector
Cover RH Pos. Bypass- far Dimensions (in.) Hub 5th Jaw No. of Cont. Catalog
Style Service Line Load Load RH Position W H D Opening Kit No. Pos. Amps/Pos Number
Ringless OH/UG #6-250 kcmil #8-2/0 #6-250 kcmil Lever 35.0 17.4 4.9 RX Cl. Plate 659-0121 3 125 UA3X11-ZG
Ringless OH/UG #6-250 kcmil #8-2/0 #6-250 kcmil Lever 43.2 17.4 4.9 RX Cl. Plate 659-0121 4 125 UA4X11-ZG
Ringless OH/UG #6-250 kcmil #8-2/0 #6-250 kcmil Lever 51.3 17.4 4.9 RX Cl. Plate 659-0121 5 125 UA5X11-ZG
OWNER’S METER LEVER BYPASS MULTI-POSITION METERING
Common Features
J 125A continuous duty rated
J Ample wiring room
J 200A capable lever bypass position
UA3X11-ZG
Product Schedule 418
51
������������������
Common Features
J 20A continuous rated
J Ground lug available
J Steel or aluminum construction
J Split or solid cover construction
J OH and UG capabilities
J 600V rated
J Spacing for multiple test switch configurations
J Customized test switch and wiring
TYPE PTS TRANSFORMER-RATED METER MOUNTING EQUIPMENT WITH TEST SWITCH PROVISION
Catalog Numbers Cont.
Socket Ringless - Solid Cover Ringless - Split Cover Ring Type - Split Cover Dimensions (in.) Amp Hub Terminal Wire Range
Type Aluminum Steel Aluminum Steel Aluminum Steel L W D Rating Opening Current Potential
PTS6: 6 Jaw 9837-8200 9837-8201 9837-8202 9837-8203 9837-8204 9837-8205 20.0 12.0 4.5 20 RX Cl. Plate #4-14 #8-14
9837-8210 9837-8211 9837-8212 9837-8213 9837-8214 9837-8215 20.0 12.0 4.5 20 1” Hub Inst. #4-14 #8-14
9837-8220 9837-8221 9837-8222 9837-8223 9837-8224 9837-8225 20.0 12.0 4.5 20 1.25” Hub Inst. #4-14 #8-14
9837-8230 9837-8231 9837-8232 9837-8233 9837-8234 9837-8235 20.0 12.0 4.5 20 1.50” Hub Inst. #4-14 #8-14
9837-8240 9837-8241 9837-8242 9837-8243 9837-8244 9837-8245 20.0 12.0 4.5 20 RX Opening #4-14 #8-14
PTS8: 8 Jaw 9837-8400 9837-8401 9837-8402 9837-8403 9837-8404 9837-8405 20.0 12.0 4.5 20 RX Cl. Plate #4-14 #8-14
9837-8410 9837-8411 9837-8412 9837-8413 9837-8414 9837-8415 20.0 12.0 4.5 20 1” Hub Inst. #4-14 #8-14
9837-8420 9837-8421 9837-8422 9837-8423 9837-8424 9837-8425 20.0 12.0 4.5 20 1.25” Hub Inst . #4-14 #8-14
9837-8430 9837-8431 9837-8432 9837-8433 9837-8434 9837-8435 20.0 12.0 4.5 20 1.50” Hub Inst. #4-14 #8-14
9837-8440 9837-8441 9837-8442 9837-8443 9837-8444 9837-8445 20.0 12.0 4.5 20 RX Opening #4-14 #8-14
PTS13: 13 Jaw 9837-8500 9837-8501 9837-8502 9837-8503 9837-8504 9837-8505 20.0 12.0 4.5 20 RX Cl. Plate #4-14 #8-14
9837-8510 9837-8511 9837-8512 9837-8513 9837-8514 9837-8515 20.0 12.0 4.5 20 1” Hub Inst. #4-14 #8-14
9837-8520 9837-8521 9837-8522 9837-8523 9837-8524 9837-8525 20.0 12.0 4.5 20 1.25” Hub Inst #4-14 #8-14
9837-8530 9837-8531 9837-8532 9837-8533 9837-8534 9837-8535 20.0 12.0 4.5 20 1.50” Hub Inst. #4-14 #8-14
9837-8540 9837-8541 9837-8542 9837-8543 9837-8544 9837-8544 20.0 12.0 4.5 20 RX Opening #4-14 #8-14
KNOCKOUTS (inches):
B: 1/2, 3/4
Q: 1, 1-1/4, 1-1/2
AC: 1/4, 1/2
RX: x2.750 HUB 0P
Consult the factory for other available options such as, but not limited to alternate
enclosure and hasp material, kearnaloxed terminals, enclosures with special KO
configurations, pre-wired units, test switch specifications and special labeling.
Capacity: 20 amperes, 600 volts a.c.
Application: Transformer-rated applications. Available with or without test switch and pre-wiring.
Enclosures: 14-gauge .063 aluminum or 16-gauge galvannealed steel suitable for indoor or outdoor installation.
Terminals: Set screw type .
Hubs: Interchangeable 1”, 1-1/4”, 1-1/2”
Finish: Aluminum unpainted unless specified. Steel enclosures have gray polyester powder coat finish.
Test Switches: Standard 6 and 10 pole, 480-volt rated switches are available from stock. Special switches available upon request.
GENERAL INFORMATION:
Product Schedule 465
52
Common Features
J Clamping jaw lever bypass
J 80A continuous rated
J Ground lug available
J Screw type terminals with pressure plate
J Steel or aluminum construction
J Glass filled polyester block construction
J 200% rated bypass
J Overhead and underground capabilities
J 600V rated
TYPE HQ-T TRANSFORMER-RATED METER MOUNTING EQUIPMENT
Socket Catalog Numbers Dimensions (inches) Continuous Hub Terminal Wire Range
Type Removable Handle Solid Handle L W D Ampere Rating Opening Current Term Potential Term
HQ-6T: 6 Jaw 9804-8544 9804-8548 17.5 10.0 5.0 80 RX Cl. Plate #4-14 #8-14
9804-8482 9804-8485 17.5 10.0 5.0 80 1” Hub Installed #4-14 #8-14
9804-8483 9804-8486 17.5 10.0 5.0 80 1.25” Hub Installed #4-14 #8-14
HQ-8T: 8 Jaw 9804-8542 9804-8546 17.5 10.0 5.0 80 RX Cl. Plate #4-14 #8-14
9804-8419 9804-8456 17.5 10.0 5.0 80 1” Hub Installed #4-14 #8-14
9804-8422 9804-8459 17.5 10.0 5.0 80 1.25” Hub Installed #4-14 #8-14
HQ-13T: 13 Jaw 9804-8543 9804-8547 17.5 10.0 5.0 80 RX Cl. Plate #4-14 #8-14
9804-8420 9804-8457 17.5 10.0 5.0 80 1” Hub Installed #4-14 #8-14
9804-8423 9804-8460 17.5 10.0 5.0 80 1.25” Hub Installed #4-14 #8-14
9804-8426 9804-8463 17.5 10.0 5.0 80 1.50” Hub Installed #4-14 #8-14
Consult the factory for other available options such as, but not limited to alternate
enclosure and hasp material, kearnaloxed terminals, enclosures with special KO
configurations and special labeling.
KNOCKOUTS (inches):
Capacity: 80 ampere continuous, 600 volts a.c.
Application: 6 terminal, single phase 2 or 3 wire; 8 terminal 2 or 3 phase, 3 wire, HQ-13T - 3 phase, 4 wire wye or 4 wire delta. For use
with transformer-rated Class 10 or 20 meters. May also be used on self-contained applications up to 80 ampere load.
Enclosures: Constructed of 16 gauge galvannealed steel with polyester powder coat finish. Also available in 12 gauge aluminum
upon request. All enclosures are NEMA type 3R.
Block Assembly: Glass fiber reinforced polyester. High strength, arc and track resistant.
Bypass: Lever-Operated Jaw Release - Moving lever up closes bypass, providing positive short circuiting of the current circuits and
releases jaw pressure on the meter current terminals providing easy removal of the meter. Also available is a removable
bypass handle which allows a solid cover, #37943-2 for HQ-T or #54199-2 for HQ-TS, to be placed on the box with the
bypass closed when it is necessary to remove the meter for in-shop repair or testing. Bypass capacity: 80 amp continuous.
Terminals: Set screw type with pressure plate. Current terminals will accommodate conductors from #4 to #14. Potential terminals will
accommodate from #8 to #14.
Hubs: Cover plate or single removable gasketless hubs are interchangeable.
UL: All sockets shown are UL approved.
Safety Shield: Track resistant polycarbonate transparent safety shield provides liberal insulation between potential jaws and terminals
and protection from accidental shorts and shocks.
GENERAL INFORMATION:
: 1/4
B: 1/2, 3/4
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
AI: 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
RX: x2.750 HUB 0P
Product Schedule 467
53
CONNECTIONS:
HQ-13T
HQ-6T
Form 6S Form 8S Form 9S Form 10S
Form 5S Form 4S Form 3S
(2 WIRE CT)
Form 3S
(3 WIRE CT)
HQ-8T
Product Schedule 467
54
Common Features
J Clamping jaw lever bypass
J 80A continuous rated
J Ground lug available
J Screw type terminals with pressure plate
J Steel or aluminum construction
J Glass filled polyester block construction
J 200% rated bypass
J Overhead and underground capabilities
J 600V rated
J Spacing for multiple test switch configurations
TYPE HQ-TS TRANSFORMER-RATED METER MOUNTING EQUIPMENT WITH TEST SWITCH PROVISION
Socket Catalog Numbers Dimensions (inches) Continuous Hub Terminal Wire Range
Type Removable Handle Solid Handle L W D Ampere Rating Opening Current Term Potential Term
HQ-6T: 6 Jaw 9804-8557 9804-8561 19.0 13.0 5.0 80 RX Cl. Plate #4-14 #8-14
9804-8494 9804-8497 19.0 13.0 5.0 80 1” Hub Installed #4-14 #8-14
9804-8495 9804-8498 19.0 13.0 5.0 80 1.25” Hub Installed #4-14 #8-14
9804-8496 9804-8499 19.0 13.0 5.0 80 RX Opening #4-14 #8-14
HQ-8T: 8 Jaw 9804-8559 9804-8563 19.0 13.0 5.0 80 RX Cl. Plate #4-14 #8-14
9804-8518 9804-8521 19.0 13.0 5.0 80 1” Hub Installed #4-14 #8-14
9804-8519 9804-8522 19.0 13.0 5.0 80 1.25” Hub Installed #4-14 #8-14
9804-8669 9804-8523 19.0 13.0 5.0 80 RX Opening #4-14 #8-14
HQ-13T: 13 Jaw 9804-8560 9804-8564 19.0 13.0 5.0 80 RX Cl. Plate #4-14 #8-14
9804-8530 9804-8533 19.0 13.0 5.0 80 1” Hub Installed #4-14 #8-14
9804-8531 9804-8534 19.0 13.0 5.0 80 1.25” Hub Installed #4-14 #8-14
9804-8532 19.0 13.0 5.0 80 RX Opening #4-14 #8-14
Capacity: 80 ampere continuous, 600 volts a.c.
Application: HQ-6TS - Single phase, 2 or 3 wire, HQ-8TS - 2 or 3 phase, 3 wire
HQ-13TS - 3 phase, 4 wire wye or 4 wire delta
For use with transformer-rated Class 10 or Class 20 meters and appropriate meter test switch.
Enclosures: Ringless. Constructed of 16 gauge galvannealed steel with baked enamel finish for indoor or outdoor installation. Also
available in 12 gauge aluminum upon request. Box is adequately dimensioned and has mounting holes provided for test
switch installation. All enclosures are NEMA type 3R.
Block Assembly: Glass fiber reinforced polyester. High strength, arc and track resistant.
Bypass: Jaw release type. Moving lever up closes bypass providing positive short circuiting of the current circuits and releases jaw
pressure on the meter current terminals providing easy removal of the meter. Also available is a removable bypass handle
which allows a solid cover (#54199-2) to be placed on the box with the bypass closed when it is necessary to remove the
meter for in-shop repair or testing. Bypass capacity: 80 amp continuous.
Terminals: Set screw type with pressure plate. Current terminals will accommodate conductors from #4 to #14 copper or aluminum.
Potential terminals will accommodate conductors from #8 to #14 copper or aluminum.
Hubs: Available with cover plate or single removable gasketless hub. Hubs and cover plate are interchangeable.
UL: All sockets shown are UL approved.
GENERAL INFORMATION:
Consult the factory for other available options such as, but not limited to alternate
enclosure and hasp material, kearnaloxed terminals, enclosures with special KO
configurations and special labeling.
KNOCKOUTS (inches):
: 1/4
A: 1/2
AF: 1, 1-1/2, 2, 2-1/2, 3
AG: 3/4, 1, 1-1/4, 1-1/2, 2, 2-1/2, 3
RX: x2.750 HUB 0P
Product Schedule 469
55
HQ-7TS HQ-8TS
CONNECTIONS:
HQ-13TS
Form 6S Form 8S Form 9S Form 10S
Form 7S Form 24S
Form 5S
Safety Shield: Track resistant polycarbonate transparent insulating safety shield provides protection from accidental shorts and shocks.
Potential terminals are mounted in the safety shield for ease of wiring and testing.
Test Switch An insulated mounting bracket is included below the meter socket for the customer installation of a standard test switch.
Mounting: Holes are provided for No. 10-32 mounting screws.
Knockouts: All box enclosures have one 1”, 1 1/4”, 1 1/2” concentric knockout in the back, and three 1”, 1 1/4”, 1 1/2” concentric
knockouts in the bottom. There are no knockouts in the sides. In addition, there are one 1/4” knockout and one 1/2”, 3/4”
concentric knockout in the bottom.
GENERAL INFORMATION (continued):
HQ-6TS
Form 4S Form 3S
(2 WIRE CT)
Form 3S
(3 WIRE CT)
Product Schedule 469
56
Common Features
J 200A and 320A continuous duty models
available
J Factory installed lugs or studs
J Ground lug on all devices
J Horn or lever bypass (uses HQ lever bypass)
J Extension kits available for pedestals
J Breaker devices with provisions or installed
breaker
J Pole mount units with breakers available
J Direct burial or pad mount capability
200/320A 4-7 TERMINAL PEDESTAL AND BREAKER COMBINATION METER MOUNTING EQUIPMENT
Cont.
Amps No. of Terminal Connector Dimensions (inches) Hub 5th Jaw Breaker Catalog
Pos. Term. Service Line Load Bypass W H D Opening Kit No. Breaker Type Number
200 4 OH #14-2/0 See Breaker Horn 8.0 28.5 4.5 RX Opening H659-0121 125A-prov. QP UAB111-0PCHb
200 4 OH #6-350 kcmil #6-300 kcmil Horn 8.0 28.5 4.5 RX Opening H659-0121 200A-inst. QJ UAB317-0PCHa
200 4 OH/UG (2) 1/0-600 kcmil #6-350 kcmil None 11.3 28.5 4.3 RX Cl. Plate H659-0121 200A-inst. QJ UAB417-XGb
125 5 OH/UG #6-250 kcmil #2-1/0 CU, 2/0 AL Horn 18.5 17.0 5.1 RX Cl. Plate Installed 125A inst. QN LGMM0202B1125RJBXb
150 5 OH/UG #6-250 kcmil #1-300 KCMIL Horn 18.5 17.0 5.1 RX Cl. Plate Installed 150A inst. QN LGMM0202B1150RJBXb
200 5 OH/UG #6-250 kcmil #1-300 KCMIL Horn 18.5 17.0 5.1 RX Cl. Plate Installed 200A inst. QN LGMM0202B1200RJBXb
125 4 OH/UG #14-2/0 See Breaker None 10.9 20.8 4.4 RX Cl. Plate H659-0121 QP UAB111-XGb
100 4 OH/UG #14-2/0 See Breaker None 10.9 20.8 4.4 RX Cl. Plate H659-0121 QP UAB111-100b
125 4 OH/UG #14-2/0 See Breaker None 10.9 20.8 4.4 RX Cl. Plate H659-0121 QP UAB111-125b
200 4 OH/UG #6-350 kcmil See Breaker None 11.6 27.8 5.2 RX Cl. Plate H659-0121 QN/QP UAB417-XPGb
150 4 OH/UG #6-350 kcmil See Breaker None 11.6 27.8 5.2 RX Cl. Plate H659-0121 QN UAB417-150b
200 4 OH/UG #6-350 kcmil See Breaker None 11.6 27.8 5.2 RX Cl. Plate H659-0121 QN UAB417-200b
200 4 UG #6-350 kcmil See Breaker None 13.2 25.2 5.2 Blank Top H659-0121 QN UAB877-PGb
200 4 UG #6-350 kcmil See Breaker None 13.2 25.2 5.2 Blank Top H659-0121 QN UAB877-200b
Cont.
Amps No. of Terminal Connector Dimensions (inches) Hub 5th Jaw Breaker Catalog
Pos. Term. Service Line Load Bypass W H D Opening Kit No. Breaker Type Number
200 4 UG 4/0-comp. lug #6-350 kcmil Horn 8.0 64.5 4.5 Blank Top H659-0121 None N/A UAP317-PPCHb
200 4 UG #6-350 kcmil #6-350 kcmil Horn 8.0 64.5 4.5 Blank Top H659-0121 None N/A UAP317-PPWIb
200 4 UG 4/0-comp. lug See Breaker Horn 8.0 64.5 4.5 Blank Top H659-0121 200A-prov. QPP UAPB317-PPCHb
200 4 UG 4/0-comp. lug See Breaker Horn 8.0 64.5 4.5 Blank Top H659-0121 200A-prov. QPP UAPB317-PPWIb
200 4 UG 4/0-comp. lug #4-1/0 Horn 8.0 64.5 4.5 Blank Top H659-0121 100A-inst. QP UAPC311-PPCHb
200 4 UG 4/0-comp. lug #4-250 kcmil Horn 8.0 64.5 4.5 Blank Top H659-0121 200A-inst. QPP UAPC317-PPCHb
200 4 UG 4/0-comp. lug #4-2/0 Horn 8.0 64.5 4.5 Blank Top H659-0121 125A-inst. QP UAPC318-PPCHb
200 5 UG #6-350 kcmil #6-350 kcmil Lever 11.0 56.0 6.0 Blank Top N/A None N/A 40405P-9WIb
200 7 UG #6-350 kcmil #6-350 kcmil Lever 11.0 56.0 6.0 Blank Top N/A None N/A 40407P-9CHb
200 7 UG #6-350 kcmil #6-350 kcmil Lever 11.0 56.0 6.0 Blank Top N/A None N/A 40407P-9UEb
200 7 UG (2) #4-350 kcmil (2) #4-350 kcmil Lever 11.0 56.0 6.0 Blank Top N/A None N/A 40407P-9WIb
320 4 UG 3/8”-24 Stud (2) #4-350 kcmil Lever 13.0 56.0 5.0 Blank Top H35815-2 None N/A 47604P-9CHb
320 4 UG 1/0-600 kcmil #6-350 kcmil Lever 13.0 56.0 5.0 Blank Top H35815-2 None N/A 47604P-9WIb
320 4 UG 3/8”-24 Stud #6-350 kcmil Lever 13.0 56.0 5.0 Blank Top H35815-2 (2) 200A-inst. QJ 47604PB-9CHb
47604-9CH UAB317-0PCH UAPB317-PPCH
Product Schedule 480
a Ring style cover.
b Ringless style cover.
Pedestal
Combo
57
Capacity: HQ-4SP, HQ-5P, HW-7P: 200 and 320 amperes continuous, 600 volts a.c.
UAB: 100 and 200 amperes continuous, 600 volts a.c.
UAP: 200 amperes continuous, 600 volts, a.c.
Application: HQ-4SP, HQ-5P, HQ-7P: 3 phase, 4 wire wye or delta (7 terminal); 2 phase, 3 wire wye or delta (5 terminal). Single phase 3 wire
320 amp (4 terminal) for underground service.
UAB: Single phase, 3 wire (4 terminal) for overhead service.
UAP: Single phase, 3 wire (4 terminal) for underground service.
Enclosures: HQ-4SP, HQ-5P, HQ-7P: and UAP: NEMA Type 3R ringless, 16 gauge polyester painted G-90 steel above ground, G-210 steel
below grade level.
UAB: NEMA Type 3R, ringless, 16 gauge polyester painted G-90 steel.
Block Assembly: HQ-4SP, HQ-5P, HQ-7P: Standard Type HQ block with glass filled polyester base.
UAB: Standard Type A residential block with strong, arc and track resistant, glass-filled polyester base.
UAP: Standard Type A residential block with strong, arc and track resistant, phenolic base.
Terminals: HQ-4SP, HQ-5P, HQ-7P: Lay-in style tin-plated copper on load side; 3/8” studs on line side.
UAB and UAP: Lay-in style tin-plated extruded aluminum.
UL: All sockets shown are UL approved.
ANSI C-12.7: All sockets meet or exceed ANSI C-12.7 standards.
GENERAL INFORMATION:
KNOCKOUT DIAGRAMS:
HQ-P
Amps Breaker Type
100 L2100 UAPB/UAPC/UAB1
125 L2125 UAPB/UAPC/UAB1
150 L2150B UAPB/UAPC
200 L2200B UAPB/UAPC
200 LJ22B200 UAB3, UAB4, 47604PB
225 L2225B UAPB/UAPC
BREAKER TABLE:
Pedestal Type Catalog Number
UAP 5007718
4040XP 5007720
47604P 5007719
Plate For Pad Mount
UAP 5007714
EXTENSION KITS:
KNOCKOUTS (inches):
: 1/4
A: 1/2
R: 1, 1-1/4, 1-1/2, 2
S: 1, 1-1/4, 1-1/2, 2, 2-1/2
VV: 2
RX: x2.750 HUB 0P
Product Schedule 480
58
Dimensions (in.) Hub Main No. Cover Catalog
Rating Service W H D Opening Breaker Term. Bypass Style Number
200 OH/UG 30.0 14.0 5.0 RX Cl. Plate 200A inst. 4 None Ringless LG0408B1200RT
200 OH/UG 32.0 14.0 5.0 RX Cl. Plate 200A inst 4 None Ringless LG0816B1200RCT
200 OH/UG 27.0 14.0 5.0 RX Cl. Plate None 4 None Ringless LG0606L1200R
200 OH/UG 27.0 14.0 5.0 RX Cl. Plate None 4 None Ringless LG0606L1200RA*
400 OH 29.0 27.0 6.0 HD Cl. Plate None 4 Lever Ringless LG0404L1400RLM
400 OH 29.0 27.0 6.0 HD Cl. Plate 200A inst. 4 Lever Ringless LG0816B1400RLT
space for one
more 200A main
LG0408B1200RT
4 space, 8 circuit feed thru lugs
LG0816B1200RCT
8 space, 16 circuit feed thru lugs
* Aluminum enclosure.
LG0404L1400RLM
Accepts 2 main breakers 60-200A each
LG0816B1400RLT
8 space, 10 circuit feed thru lugs
LG0606L1200R
12 space, 6 circuit
LG0606L1200RA
2 or 4 pole breakers only
200A/400A METER MOUNTING EQUIPMENT, METER MAIN, RESIDENTIAL – 4 & 5 TERMINAL FOR 1 PHASE, 3 WIRE
59
Description Amps Catalog No.
1-Pole 120V 15 L115
1-Pole 120V 20 L120
2-Pole 120/240V 20 L220
2-Pole 120/240V 30 L230
2-Pole 120/240V 40 L240
2-Pole 120/240V 50 L250
2-Pole 120/240V 60 L260
2-Pole 120/240V 100 L2100
2-Pole 120/240V 125 L2125
4-Pole 120/240V 150 LN2150R
4-Pole 120/240V 200 LN2200R
Accessories Catalog No.
Single Pole Padlocking Device ECPLD1
Double Pole Padlocking Device ECPLD2
4-Pole Padlocking Device ECQLN3
Handle Blocking Device (1 & 2 Pole) ECQL1
Single Pole
Double Pole
4-Pole
CIRCUIT BREAKERS
Common Features
J Plug in
J UL listed for use with Talon branded meter combinations
J 1” Frame
60
Air Conditioning Disconnects
Fused and Non-fused
Features:
Flexibility
L 30-60 amperes
L 240 volts A.C.
L Padlock provisions
L Horsepower rated
L 10,000 A.I.C.
L New models available with internal GFCI receptacle
L Removable door
L Ample wiring space
Rugged Durability
L Noryl® thermoplastic and powder coated G90 steel
enclosures are corrosion resistant and extremely durable
giving long maintenance free service
L Copper conductors
L Raised mounting embosses
Steel AC Disconnects
Ampere
rating
Disconnect
type
Catalog
number
Horse power
rating
Dimensions (inches)
H W D
30 Fused pullout LF2030 37.3 5.0 2.1
60 Fused pullout LF2060 10 8.0 5.0 2.1
60 Non-fused pullout LN2060 10 7.3 5.0 2.1
60 Non-automatic switch LNAS2060 10 7.3 5.0 2.1
Plastic AC Disconnects
Ampere
rating
Disconnect
type
Catalog
number
Horse power
rating
Dimensions (inches)
H W D
30 Fused pullout LF2030PL 38.0 5.3 3.1
60 Fused pullout LF2060PL 10 8.0 5.3 3.1
60 Non-fused pullout LN2060PL 10 7.3 5.0 2.1
60 Non-fused pullout LN2060PLX 10 8.0 6.0 5.8
Steel AC Disconnects with 15 Amp GFCI Receptacle
Ampere
rating
Disconnect
type
Catalog
number
Horse power
rating
Dimensions (inches)
H W D
30 Fused pullout LF2030GFCI 39.0 6.1 5.1
60 Fused pullout LF2060GFCI 10 9.0 6.1 5.1
60 Non-fused pullout LN2060GFCI 10 7.1 5.8 5.1
60 Non-automatic switch LNAS2060GFCI 10 7.1 5.8 5.1
Wire Range Table
Copper Aluminum
Connector Solid Stranded Solid Stranded
Line #14-8 #14-3 #12-8 #12-3
Load #14-8 #14-3 #12-8 #12-3
Neutral #12-8 #12-2 #12-8 #12-2
Equip. grnd. #12-8 #12-2 #12-8 #12-2
61
Spa Panels
For use as spa/hot tub service disconnect
2-Pole
GFCI breaker
Dimensions (inches) Catalog
numberH W D
50A 12.3 6.0 4.5 LGSPA50
60A 12.3 6.0 4.5 LGSPA60
Features:
L UL Listed
L Factory installed, 2-pole 50A or 60A GFCI breaker for 240V ground fault protection
L NEMA Type 3R outdoor enclosure
L 2 extra spaces (4 circuits manimum) for additional circuit breakers
L 125 Amp rated interior
L Factory installed 5 position ground bar
L Closure plate included
L Compact enclosure size
L Convenient standard package of 1
L Uses reliable Siemens circuit breakers
dead front enclosure hub cover plate
included
12-1/4-”
6”
62
Product Schedule 497
Connector Lugs
H55890
#6-350 kcmil
3/8”
Stud
H55890-1
#6-350 kcmil
3/8”
Stud
H56734
#6-250 kcmil
1/2”
Stud
H37892
#4-500 kcmil
1/2”
Stud
H61300
(1) #4-600 kcmil [or]
(2) #1/0-250 kcmil
1/2”
Stud
H56732-2
(2) #4-350 kcmil
3/8”
Stud
H56477
#3/0-800 kcmil
1/2”
Stud
H56733
#3/0-800 kcmil
1/2”
Stud
H59299-1 1/2”
Stud
H57606-K
#6-350 kcmil
3/8”
Stud
H58022
(2) #6-250 kcmil
3/8”
Stud
H56732-M
(2) #4-500 kcmil
1/2”
Stud
H56425
(2) #6-350 kcmil
1/2”
Stud
H56427
(2) #6-350 kcmil
1/2”
Stud
H56476
#3/0-800 kcmil
1/2”
Stud
H56732
(2) #4-350 kcmil
1/2”
Stud
H68752-1
(3) #6-250 kcmil
1/2”
Stud
H56425-M
(2) #4-500 kcmil
1/2”
Stud
H56427-M
(2) #4-500 kcmil
1/2”
Stud
H60162
(1) #4-600 kcmil [or]
(2) #1/0-250 kcmil
1/2”
Stud
H56732-1
(2) #4-350 kcmil
1/2”
Stud
H56426
(4) #6-350 kcmil
1/2”
Stud
H58852
#3/0-800 kcmil
1/2”
Stud
H58853
(2) #6-350 kcmil
1/2”
Stud
63
Product Schedule 497
Connector Lugs
Pressure type lugs for Talon’s stud type meter mounting devices are made of 6061-T6 aluminum to provide high
strength and high conductivity. All lugs are tin-plated to ensure low contact resistance and to reduce corrosion.
Allen or hex head pressure screws are furnished to provide excellent conductor spread for maximum binding action
with the lug. All Talon lugs are listed with Underwriters Laboratories.
Pressure lug connectors for meter mounting devices
Device
type
Conductor
size
Stud
opening
Pressure
screw head
Dimensions* (inches)
L W H
Anti-
rotation
feature
Catalog
number
#6-350 kcmil 13/32” 9/16” Hex 2-1/4 1-1/8 1-1/4 No H55890
HQ-4S #6-350 kcmil 13/32” 5/16” Allen 2-1/4 1-1/8 1-1/4 No H55890-1
HQ-5 S #6-350 kcmil 13/32” 3/8” Allen 2-1/4 1-1/8 1-1/4 No H57606-K
HQ-7S (2) #6-250 kcmil 13/32” 5/16” Allen 2-3/16 1-5/8 1-3/16 No H58022
HQ-4D #4-500 kcmil 9/16” 3/8” Allen 2-13/16 1-1/2 1-9/16 No H37892
HQ-5DM
HQ-7D, HQ-7DF
(1) #4-600 kcmil or
(2) #1/0-250 kcmil 9/16” 1/2” Allen 2-13/16 1-3/8 1-13/16 Yes H60162
No H61300
K-4,5,7 (2) #6-350 kcmil 9/16” 5/16” Allen 2-7/8 1-57/64 1-1/4 No H56425
K-4,5,7 (2) #4-500 kcmil 9/16” 3/8” Allen 2-13/16 2-1/16 1-9/16 No H56425-M
K-4 (4) #6-350 kcmil 9/16” 5/16” Allen 2-7/8 3-15/16 1-1/4 No H56426
K-4,5,7 (2) #6-350 kcmil 9/16” 5/16” Allen 4-15/16 1-1/8 2-1/16 Yes H56427
K-4,5,7 (2) #2-500 kcmil 9/16” 3/8” Allen 4-1/4 1-1/8 1-13/16 Yes H56427-M
K-5,7 #3/0-800 kcmil 9/16” 1/2” Allen 3-1/4 1-5/16 1-13/16 Yes H56476
K-4,5,7 #3/0-800 kcmil 9/16” 1/2” Allen 3-1/4 1-5/16 1-13/16 Yes H56477
K-5,7 (2) #4-500 kcmil 9/16” 3/8” Allen 2-13/16 2-5/32 1-9/16 No H56490
K-5,7 (2) #4-350 kcmil 9/16” 5/16” Allen 2-7/8 1-59/64 1-1/4 Yes H56732
K-5,7 (2) #4-350 kcmil 9/16” 5/16” Allen 2-7/8 1-59/64 1-1/4 No H56732-1
K-5,7 (2) #4-500 kcmil 9/16” 3/8” Allen 2-13/16 2-5/32 1-13/16 Yes H56732-M
K-4,5,7 #3/0-800 kcmil 9/16” 1/2” Allen 4-3/16 1-3/4 2-3/8 Yes H56733
K-4,5,7 (Grd.) #6-250 kcmil 9/16” 5/16” Allen 2-9/16 1-9/32 1-3/16 No H56734
K-4,5,7 #3/0-800 kcmil 9/16” 1/2” Allen 3-15/16 1-3/4 1-13/16 Yes H58852
K-4,5,7 (2) #6-350 kcmil 9/16” 5/16” Allen 3-15/16 1-1/8 1-1/2 Yes H58853
K-4,5,7 (3) #6-250 kcmil 9/16” 5/16” Allen 2-7/8 2-31/64 1-7/16 Yes H68752-1
K-4 extender 1/2-20 x 1-7/8” Stud 9/16” None 4-1/4 1-1/4 2-3/8 Yes H59299-1
Lug Extender
Device type Stud opening Stud size
Dimensions (inches)
W H D
Catalog
number
K-4 9/16” 1/2-20 x 1-7/8” 4-1/4 1-1/4 2-3/8 H59299-1**
* Dimensions do not include height of pressure screw with conductor installed.
** Includes nut and washer assembly and washer.
WL
H
64
Product Schedule 498
Accessories
Sealing rings
Description
Catalog
number
Stainless Steel
Snap Type
H54602
Stainless Steel
Screw Type H9738-8002
Black plastic meter
opening cover
H39968
Clear plastic meter
opening cover
(with plug-in feet)
H659-0162
UAT, UAS, MQ and HQ Accessories
Description
Catalog
number
Insulated 5th terminal kit - Type
AS, AT only
Grounded 5th terminal kit - Type
AS, AT only
Anti -Inversion Clip for HQ Sockets
H659-0120
H659-0121
H59676
MQ 5th terminal kit - 9:00
HQ 5th terminal kit - 9:00
w/o wire
HQ 5th terminal kit - 9:00
w/ wire
HQ 5th teminal kit - 9:00
w/ 9” lead
*For use with side wired devices only.
H8059864
H35815-2
H35815-3
H35815-5*
Grey touch-up paint
-TUP61, 12 oz. can XPT060
Ground strap kit, HQ-5
Ground lug kit, #14-2
Add-on grounding lug
for HQ/HQU
35566-1
H36503
H55303
HQ isolated neutral kit
(for 200A only,
not for use with 320A)
*Includes neutral and isolation block
H64685-1*
Neutral isolation kit for HQ
(for 200A only,
not for use with 320A)
*Isolates existing neutral
H64690-1*
Insulated Jumper H36479
7/8” Barrel Lock Guard HBRLLOCK
Removable hub kits
Conduit Size
(inches)
Catalog
number
RX type hubs small
1H38596-2
1-1/4 H38597-2
1-1/2 H38598-2
2H38599-2
2-1/2 H38600-2
Cover plate - steel H38595-1
Cover plate - aluminum H38595-2
HD Type Hubs Large
3H56856-2
3-1/2 H56857-2
4H56858-2
Cover plate - steel H56933
Cover plate - aluminum H56933-1
Large to small adaptor -
steel HD to RX
H9747-1113
Large to small adaptor -
aluminum HD to RX
H9747-1112
Removable hub
Cover plate
K-Base Accessories
Description
Catalog
number
K-7 only Isolated
Neutral Kit H69685-1
K-7 Rotary Bypass -
600 Amp rated H69623
K-7 Rake Type Bypass -
600 Amp rated,
temp use only
H58888
K-4 Rake Type Bypass -
600 Amp rated,
temp use only
H56495
Insulated T-Handle Wrench
Magnetic Hex Socket*
*For use on meter
Not for use on K7
H69232-1
H69546-1
65
Accessories
Catalog
Description Number
Solid Cover for 10” x 17.5” Box
Steel H37943-4
Aluminum H37943-5
Solid Cover for 13” x 19” Box
Steel H54199-4
Aluminum H54199-5
Solid Cover for 20” x 34” Box
Steel A-300706-4
Cover Plates
Catalog
Description Number
K-7 Adapter Block for CTs A301555-3
Blank Sliding Cover for K Base (order with A-301555-3)
Steel (for K-4 or K-7) HA-300529-3
Aluminum (for K-4 or K-7) HA-300529-4
C. T. Conversion Kits
Catalog
Description Number
Lexan Shield for K7 5007399-K
(includes mounting
hardware)
Lexan Shield for K4 5007400-K
(includes mounting
hardware)
K-Base - All (Replacement)
Steel Sliding Plate H56721
(w/ meter opening)
Aluminum Sliding Plate H56721-1
(w/ meter opening)
K- Base Lexan Shields and Replacement Sliding Plates
Catalog
Description Number
Convert 200A 7 Jaw Anchor 67959-1
to Talon HQ7
Convert 200A 7 Jaw Anchor 67959-3
to Talon HQ7 with neutral
Convert 200A 4/5 Jaw Anchor 68724-1
to Talon HQ5
a Conversion kits are for use in anchor 200A lever bypass units.
Self contained
enclosures only.
Conversion Kits a
Product Schedule 498
66
Product Schedule 500
Terms of Sale,
Meter Mounting Device Applications
Terms of sale
Transportation Charges: Prices listed are F.O.B. factory with freight prepaid and allowed on all shipments
of orders of $1,000 net or more for single shipments to one location.
Minimum Billing: $400 net plus transportation charges.
Cancellation: Orders accepted by the factory can be cancelled only with the factory’s consent and upon payment
to the seller of reasonable charges incurred by the seller which will indemnify the seller against loss.
Returns: Goods may not be returned to Talon without written authorization from the factory. A minimum 20%
restocking charge will be applicable on all returned goods. Credit will be given only for current production items
in unopened cartons. All transportation charges paid by Talon will be deducted from such credit.
Terms: Standard/Stock Products:
2% 10th net 25th for invoices dated the 1st through the 15th of the month.
2% 25th net 10th for invoices dated the 16th through the 31st of the month.
Meter Mounting Device Applications
Electrical
service
Service
type
Meter
form
Socket
type
Standard socket
Catalog number
1-phase Self-contained, 3 wire
2S 4 jaw 100A AT-1
4 jaw 200A AT-3, AT-4, MQ-4, HQ-4
2SE 4 jaw 320A HQ-4S, HQ-4D
Self-contained, bolt-in 2K K4-400/480A K-4, K-4UT
Transformer-rated, 2 wire 3S 5 jaw 20A HQ-6T, HQ-6TS, PTS-6
Transformer-rated, 3 wire 4S 6 jaw 20A HQ-6T, HQ-6TS
3-phase, 3 wire or
network Self-contained
12S 5 jaw 100A MQ-5, HQ-5
12S 5 jaw 200A MQ-5, HQ-5
12SE 5 jaw 320A HQ-5SWT, HQ-5D
Self contained bolt-in 12K K-5 480/600A K-5
Transformer-rated 5S 8 jaw 20A HQ-8T, HQ-8TS, PTS-8
3-phase, 4 wire
Wye
or Delta
Self-contained
14S
7 jaw 100/200/320A MQ-7, HQ-715S
16S
Self-contained, bolt-in
14K
K-7 480/600A K-7, K-7T15K
16K
Transformer-rated
6S
13 jaw 20A HQ-13T, HQ-13TS,
PTS-13
8S
9S
67
Notes
68
Notes
www.talonmetering.com
Subject to change without prior notice
Order No.: RPSA-PRODS-1213
All rights reserved
Printed in USA
© 2014 Siemens Industry, Inc.
Talon Meter Mounting Devices
Siemens Industry, Inc.
5400 Triangle Parkway
Norcross, GA 30092
The information provided in this brochure contains merely
general descriptions or characteristics of performance
which in case of actual use do not always apply as described
or which may change as a result of further development
of the products. An obligation to provide the respective
characteristics shall only exist if expressly agreed in the
terms of contract.
All product designations may be trademarks or product
names of Siemens AG or supplier companies whose use by
third parties for their own purposes could violate the rights
of the owners.

Navigation menu