Brochure

2016-10-06

: Pdf 1000406049-Brochure 1000406049-Brochure B5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 2

GE
Circuit
Breakers
and
Disconnects
Type THLC
Current Limiting Circuit Breakers
Unfused
15-400 Amperes
200,000
AIC at 240
Volts
ac
Max.
200,000
AIC at 480
Volts
ac
Max.
50,000
AIC at 600
Volts
ac
Max.
Type
THLC1
Internal Accessories
for
THLC1
Same
as
Type
TED
accessories.
Refer
to
pages
16-19
to
16-32.
Type
THLC2
Type
THLC1
15-150
Amps
Noninterchangeable
Trip
Includes
Line
and
Load
Lugs
Type
THLC4
Ampere
Rating
15
20
30
40
50
60
70
80
90
100
125
150
3-Pole
Catalog Number
THLC136015WL
®
THLC136020WL
®
THLC136030WL
®
THLC136040WL
®
THLC136050WL
®
THLC136060WL
THLC136070WL
THLC136080WL
THLC136090WL
THLC136100WL
THLC136125WL
THLC
1 361
50WL
List Price,
GO-1358
$1938.00
1938.00
1938.00
1938.00
1938.00
1938.00
1938.00
1938.00
1938.00
1938.00
3674.00
3674.00
Cu-AI
Lug
TCAL12
TCAL12A
TCAL15
Wire
Range
#14-3
Cu,
12-1
Al
6-2/0
Cu,
4-2/0
Al
#3-3/0
Cu,
1/0-3/0
Al
Internal Accessories
for
THLC2
and
THLC4
Same
as
Type
TFK
accessories.
@
Refer
to
pages
16-19to16-32.
Type
THLC2
125-225
Amps
Noninterchangeable
Trip
Includes Line
and
Load
Lugs
Ampere
Rating
125
150
175
200
225
Adjustable Trip
Range Amps
Low
550
675
775
900
1000
High
1250
1500
1750
2000
'
2500
3-Pole
Catalog Number
THLC236125WL
THLC236150WL
THLC236175WL
THLC236200WL
THLC236225WL
List
Price,
GO-135B
$3689.00
3689.00
3689.00
3689.00
3689.00
Cu-AI
Lug
TCAL27
Wire
Range
#4-300
komil
TypeTHLC4
250-400 Amps
Noninterchangeable
Trip
Without
Line
and
Load
Lugs®
Ampere
Rating
250
300
350
400
Adjustable Trip Range
Amps
Low
1175
1400
1650
1875
High
2500
3000
3500
4000
3-Pole
Catalog
Number
THLC436250
THLC436300
THLC436350
THLC436400
List
Price,
GO-135B
$4967.00
4967.00
4967.00
4967.00
Type
TLB4
250-400
Amps
65 kA at 480
Volts
ac
85 kA at 240
Volts
ac
Without Line
and
Load Lugs©
Ampere
Rating
250
300
350
400
Adjustable Trip Range
Amps
Low
1175
1400
1650
1875
High
2500
3000
3500
4000
3-Poie
Catalog
Number
TLB434250
TLB434300
TLB434350
TLB434400
List
Price,
GO-135B
$4278.00
4278.00
4278.00
4278.00
UjU
Suj
p
§8
KM
33
§1
"•*
CO
®
15-50A
rated
200KA
at 240 Vac
and150kAat480
Vac
maximum.
©
Accessory
must
have
code
date
535+or
later.
Lug kit for
THLC4
or
TLB4—for
line
or
load
end.
Order
Catalog
Number
TCLK43,
List
Price
$49.00,
GO-135B.
Consists
of
three-pole
assembly.
Wire
range
(1)
3/0-500
kcmil
or (2)
3/0-250
kcmil
Cu-AI.
Prices
and
data subject
to
change
without
notice
1999
Issue
16-13
Gf
Circuit
Breakers
and
Disconnects
Section
16
Spectra RMS Molded Case Circuit Breakers
Features
SE150,
SF250, SG600
and
SK1200
circuit breaker frames have
a
digital solid state,
rms
sensing trip system with field installable,
front-mounted rating plugs
to
establish
or
change
the
breaker
ampere rating Adjustable instantaneous with tracking short-time
is
standard
on all
frames including
SE150
A
complete circuit breaker consists
of a UL
listed circuit breaker
frame
and a
rating
plug
(UL
listed interchangeable trip unit)
Terminal lugs
for
cable connection
are
available
if
required
All
frames
use the
same
UL
listed field-installable internal
accessories (auxiliary switch shunt trip undervoltage release,
and
bell alarm)
All
frame sizes have
maximum
UL
listed
interrupting
ratings
of
200 kA @ 240
volts
ac and 100 kA @ 480
volts
ac
with
600
volts
ac
ratings
to 65 kA
depending
on
frame size
UL
listed current
limiting versions
are
provided through
the
SG600 frame
for the
65
kA @ 480
volts
ac and the 100 kA @ 480
volts
ac
models
with
no
increase
in
physical frame size
Spectra
RMS
Mag-Break*
instantaneous-only motor circuit
protectors
also
use the
same digital, solid-state trip unit
and
rating
plugs
as the
circuit breakers
The
interchangeable rating
plug
establishes
the
instantaneous
pickup
range (with tracking
short-time)
but
does
not
change
the
frame ampere rating
Spectra
RMS
molded case switches have
a
fixed,
high-set
instantaneous trip (without tracking short-time function)
and
have short circuit withstand ratings equal
to
their equivalent
breaker
frame
size
interrupting rating
in
most cases
Spectra
RMS
breakers
are
ambient insensitive Trip times will
not
vary
over
the
range
10-50°C
breaker
ambient
Refer
to
GET-7002
for
further
application information
Spectra
RMS
breakers contain
no
parts that would support
fungus growth
and are
therefore inherently fungusproof
Other
MCCB
Features
Broad product line
to
meet
virtually
any
application need
Reduced downtime
A
tripped breaker
is
easily spotted
and can
be
immediately reset
after
the
fault
has
been corrected
Eliminates single phasing
A
common trip
bar
disconnects
all
poles
simultaneously
on
both
overloads
and
short
circuits
Offers
application
flexibility
through
the use of a
wide variety
of
accessory
devices
and
special attachments
Repetitive operation—no fuses
to
replace
Breakers
can be
repetitively tested Fuses must
be
destroyed
to
confirm calibration accuracy
For
more information
on GE
Disconnects
and
Circuit Breakers
see
Publication Index Section
18
Fusible Switches
Nonfusible Switches
16-2
16-2
Type
FD1
Fusible Disconnect Switches
16-3
16-4
DILOS Nonfusible Disconnect Switches
16-5,16-6
Molded Case Circuit Breakers
16-7
to
16-18
Accessories
and
Modifications
16-19
to
16-32
V-Line
Miniature Circuit Breakers
16-33
to
16-36
1999
Issue
16-1

Navigation menu