In this catalogue...
Power and High Voltage
Elastimold®/ Fisher Pierce®Cable Accessories ......Section A
Homac®/ Blackburn®Overhead Connectors ..........Section B
Homac®Underground Distribution ..........................Section C
Boreal®Flexible Braids.............................................Section D
Russellstoll®Electrical Interconnection Systems .....Section E
Alphanumerical Index ...............................................Section F
Elastimold®
Fisher Pierce®Cable Accessories
w w w . t n b . c a
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A2
Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A3–A4
Standard Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A5
200 A Loadbreak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A6–A9
200 A Deadbreak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A10–A11
600 Series Deadbreak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A12–A15
600 Series Deadbreak – Cam-Op, Link-Op . . . . . . . . . . . . .A16–A17
600 Series Deadbreak – Stick-Op, Window-Op . . . . . . . . . .A18–A19
600 Series Deadbreak – Cable Joints . . . . . . . . . . . . . . . . . . .A20–A21
Molded Multi-Point Junctions . . . . . . . . . . . . . . . . . . . . . . . . .A22–A23
PCJPower Cable Joints . . . . . . . . . . . . . . . . . . . . . . . . . . . .A24–A25
Cable Terminations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A26–A29
Shield Adapters, Sealing and Grounding . . . . . . . . . . . . . . . . .A30–A31
Equipment Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A32
How to Specify Size-Sensitive Products . . . . . . . . . . . . . . . . . .A33–A34
AEIC and ICEA Cable Insulation Diameter . . . . . . . . . . . . . . . . .A35–A38
WX Size Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A39–A41
Shrink-Fit Cable Joints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A42–A43
Ranger2Terminations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A44–A49
Faulted Circuit Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A50–A57
Underground Distribution Switchgear . . . . . . . . . . . . . . . . . . .A58–A69
Molded Fuse Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A70–A79
Surge Arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A80–A85
Molded Vacuum Recloser . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A86–A87
Table of Contents
A1
Elastimold®Cable Accessories
A2
w w w . t n b . c a
Separable Elbow Connectors and their related accessories are available in
200 A loadbreak, 200 A deadbreak and 600 A deadbreak styles. Rated for padmount,
subsurface, vault, indoor, outdoor and other applications, units feature interchangeable
interfaces which can be easily engaged or separated to provide a convenient method to
connect or disconnect cable and equipment in a distribution system.
Introduction
This section provides an easy-to-use, comprehensive listing of Elastimold® products for
5 kV thru 35 kV underground power distribution systems. Included are separable elbow
connectors, cable joints, terminations and other cable accessory components. This
catalogue incorporates information relative to product application, ratings and selection.
The Thomas & Betts Elastimold®brand is recognized as the leading producer of premolded
cable accessory components worldwide. Utilizing specially formulated materials with 100%
peroxide-cured insulation and shielding, Elastimold products represent the state-of-the-art
in premolded process technology. Durable, quality construction and non-degrading,
high-reliability, maintenance-free performance is assured when specifying Elastimold
products.
Elastimold’s broad line of premolded products offers significant advantages over
field-fabricated and other alternatives, including: 100% factory assurance testing prior to
delivery and installation; simplified, single-piece construction with built-in insulating,
shielding and sealing surfaces; ease of installation with no special skills or tools required;
and compact, lightweight, durable designs for easy handling and application.
Elastimold Special Component Services Group provides custom products
tailored to specific application requirements. Please contact the factory for further
information regarding this service. For Surge Arresters see pages A80 to A85 and Fused
Elbows, see pages A70 to A79.
Cable Joints are available in permanently crimped or bolted (separable) connector
styles. Permanently crimped units are rated the same as the cable they are connecting
and are available for all applications including direct buried.
Cable Terminations are available in single-piece or modular designs. Rated for indoor,
outdoor or padmount applications, units allow connection and transition from shielded
underground cables to bare overhead conductors and live-front equipment.
Elastimold®Cable Accessories
A3
w w w . t n b . c a
Ratings
Certified Tests and Performance
Elastimold®Separable Connectors, Cable Joints, Cable Terminators and other cable accessory products have been
designed and tested per applicable portions of IEEE, ANSI and other industry standards including:
IEEE 386Standard For Separable Connectors
IEEE 404Standard For Cable Joints and Splices
IEEE 48Standard For Cable Terminations
IEEE 592Standard For Exposed
Semiconducting Shields
ANSI C119.4 Standard For Copper
and Aluminum Conductor Connectors
AEIC CS8 Standards For XLP
and EPR Insulated Cables
ICEA S-94-649-2004 and S-97-682-2000 Standard
for Cables Rated 5,000 – 46,000 V
Cable Joints and Terminations Ratings
Refer to the pages listed below for rating information:
PCJ Cable Joints, page A24 Cable Terminations, page A26 to A29
Separable Connector Ratings
Table 1 shows voltage and current ratings which apply to all Separable Connectors including 200 A Loadbreak, 200 A Deadbreak and
600 Series Deadbreak products. Table 2 shows switching and fault close ratings which only apply to 200 A Loadbreak Connectors.
Elastimold®Cable Accessories
A4
w w w . t n b . c a
Table 1 15 kV Class Ratings 25 kV Class Ratings 35 kV Class Ratings
• OPERATING VOLTAGE
Maximum line-to-ground
(See Application Info Note 1)
8.3 kV 15.2 kV 21.1 kV
• BIL Impulse withstand 1.2 x 50 microsecond wave 95 kV 125 kV 150 kV
• WITHSTAND VOLTAGE
AC One Minute
DC Fifteen Minute
34 kV
53 kV
40 kV
78 kV
50 kV
103 kV
• CORONA EXTINCTION LEVEL @ 3pC Sensitivity 11 kV 19 kV 26 kV
200 A Products
Continuous Current:
Symmetrical Momentary Current:
600 Series Products
Continuous Current:
Symmetrical Momentary Current:
200 A*
10 kA sym, 10 cycle duration
600 and 900 A*
25 kA sym, 10 cycle duration
Table 2 Loadmake/Loadbreak Switching Fault Close
15 kV
Class Ratings
1ø and 3ø circuits 8.3 kV line to ground, 14.4 kV max. across open contacts.
10 loadmake/break operations at 200 A max. with 70 to 80% lagging power factor.
1 fault close operation at 8.3 kV or 14.4 kV; 10,000 A, rms, sym. 10 cycles (0.17 sec.)
1.3 max. asym factor applies to new or used mating parts
(up to maximum designated switching operations.)
25 kV
Class Ratings
1ø and 3ø circuits 15.2 kV line to ground, 26.3 kV max. across open contacts.
10 loadmake/break operations at 200 A max. with 70 to 80% lagging power factor.
1 fault close operation at 15.2 kV or 26.3 kV; 10,000 A, rms, sym. 10 cycles (0.17 sec.)
1.3 max. asym factor applies to new or used mating parts
(up to maximum designated switching operations.)
35 kV
Class Ratings
1ø and 3ø circuits 21.1 kV line to ground, 36.6 kV max. across open contacts.
10 loadmake/break operations at 200 A max. with 70 to 80% lagging power factor.
1 fault close operation at 21.1 kV or 36.6 kV; 10,000 A, rms, sym. 10 cycles (0.17 sec.)
1.3 max. asym factor applies to new or used mating parts
(up to maximum designated switching operations.)
Application Information:
1. Loadbreak connectors are designed and rated for use on grounded WYE systems. For application on ungrounded WYE or delta systems,
the next higher voltage class product is recommended. Examples: 5 kV ungrounded: use 15 kV class products; 15 kV ungrounded: use 25 kV
class products; 25 kV ungrounded: use 35 kV class products.
2. Products are designed and constructed for all applications including padmount, subsurface, vault, indoor, outdoor, direct sunlight, direct
buried and continuously submerged in water.
3. Products are designed and rated for ambient temperatures of -40°C to +65°C. It is recommended that loadbreak connectors be hotstick
operated at -20°C to +65°C ambient temperature range and at altitudes not exceeding 6000 ft.
* Designed for 90°C maximum continuous operating temperature
Ratings
Certified Tests and Performance (cont’d)
Elastimold®Cable Accessories
A5
w w w . t n b . c a
Standard Interfaces
Standard Interfaces for Separable Connectors,
Components and Equipment Bushings
ANSI/IEEE Standard 386 defines the specific interface dimensions that 200 A and 600 Series elbows, inserts, junctions, equipment bushings
and any mating components must conform to insure interchangeability. The table below provides information concerning the types of interfaces
supplied by Elastimold for various applications and is useful to assure proper matching of components.
Bushing
Interface
Voltage
Class
Interface
Description
Standard No.
Figure No
200 A DEEPWELL
EQUIPMENT BUSHING
15 kV, 25 kV
and 35 kV
200 A Bushing
Well Interface
8.3 kV, 15.2 kV,
21.1 kV
IEEE
386-2001
Fig. 3
200 A LOADBREAK INSERT
15 kV
200 A Loadbreak
8.3 kV and
8.3 kV/14.4 kV
IEEE
386-2001
Fig. 5
200 A LOADBREAK INSERT
25 kV
200 A Loadbreak
15.2 kV and
15.2 kV/26.3 kV
IEEE
386-2001
Fig. 7, Note 1
200 A LOADBREAK INSERT
35 kV
200 A Loadbreak
Interface No. 2
21.1 kV and
21.1 kV/36.6 kV
IEEE
386-2001
Fig. 7, Note 1
200 A DEADBREAK INSERT
15 kV and 25 kV 200 A Deadbreak
8.3 kV and 15.2 kV
IEEE
386-2001
Fig. 4
600 SERIES EQUIPMENT BUSHING
15 kV and 25 kV
600 A Deadbreak
Interface No.1
8.3 kV and 15.2 kV
IEEE
386-2001
Fig. 11
600 SERIES EQUIPMENT BUSHING
35 kV
600 A Deadbreak
Interface No.1
21.1 kV
IEEE
386-2001
Fig. 13
1. Elastimold uses Fig. 7 interface for both 25 and 35 kV applications.
A
B
C
D
E
F
G
A
B
C
D
E
F
G
Elastimold®Cable Accessories
A6
w w w . t n b . c a
200 A Loadbreak
200 A loadbreak connectors and accessories provide a convenient
method to connect/disconnect cable and equipment on power
distribution systems. Loadbreak elbows include provisions for
energized operation using standard hotstick tools, allowing
loadmake/break operation and a visible disconnect. Components can
be isolated with insulated caps, plugs and parking bushings.
Optional accessories allow system grounding, testing,
bypass, lightning surge protection and current limiting fusing.
Additional connecting points and taps can be provided by use
of junctions or feed-thrus.
Ratings Overview
See page A3–A4 for complete
information including switching
and fault close ratings.
Current Ratings
200 A Continuous
10 kA sym., 10 Cycles
Voltage Ratings
15 kV Class
8.3 kV Phase-to-Ground
14.4 kV Phase-to-Phase
95 kV BIL
34 kV AC Withstand
53 kV DC Withstand
11 kV Corona Extinction
25 kV Class
15.2 kV Phase-to-Ground
26.3 kV Phase-to-Phase
125 kV BIL
40 kV AC Withstand
78 kV DC Withstand
19 kV Corona Extinction
35 kV Class
21.1 kV Phase-to-Ground
36.6 kV Phase-to-Phase
150 kV BIL
50 kV AC Withstand
103 kV DC Withstand
26 kV Corona Extinction
200 A LOADBREAK SEPARABLE CONNECTOR COMPONENTS
CABLE TO EQUIPMENT
CONNECTIONS
BUSHING
WELL
LOADBREAK
BUSHING INSERT
EXTENDED
BUSHING INSERT
BUSHING WELL
PLUG
LOADBREAK
FEED-THRU INSERT
BOLTED
ELBOW
W/TAP
OPERATING ACCESSORIES
INSULATED PARKING
BUSHING
FEED THRU
PARKING
STAND GROUNDING
PLUG
LOADBREAK ELBOW CONNECTOR
WITH OR WITHOUT TEST POINT
REPLACEMENT
ELBOW
REPAIR
ELBOW
GROUNDING
ELBOW
FUSED ELBOW
INSULATED CAP
INSULATED CAP
WITH GROUND
ASSEMBLY TOOL
SEE PAGES
A80 TO A85 FOR
SURGE ARRESTER
APPLICATIONS
Elastimold®Cable Accessories
A7
w w w . t n b . c a
200 A Loadbreak
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
Elbow
Connector
15 kV 165LR-W5X
Use Tables W1 and X1 N2, 3, 4, 5
25 kV 275LR-W5X
Use Tables W16 and X1 N2, 3, 4, 5
35 kV 375LR-W5X
Use Tables W3 and X2 N2, 3, 5
Elbow
Connector
w/ Test Point
15 kV 166LR-W5X
Use Tables W1 and X1 N2, 3, 4, 5, 24
25 kV 276LR-W5X
Use Tables W16 and X1 N2, 3, 4, 5, 24
35 kV 376LR-W5X
Use Tables W3 and X2 N2, 3, 5, 24
Jacket Seal
Elbow
Connector
15 kV 165LRJS-W5X
Use Tables W1 and X1 N2, 19
25 kV 275LRJS-W5X
Use Tables W16 and X1 N2, 19
Jacket Seal
Elbow
Connector
w/ Test Point
15 kV 166LRJS-W5X
Use Tables W1 and X1 N2, 19, 24
25 kV 276LRJS-W5X
Use Tables W16 and X1 N2, 19, 24
Repair Elbow
Connector
15 kV 167ELR-W5X
Use Tables W5 and X1 N5, 10, 18
25 kV 273ELR-W5X
Use Tables W5 and X1 N5, 10, 18
Repair Elbow
Connector
w/ Test Point
15 kV 168ELR-W5X
Use Tables W5 and X1 N5, 10, 18, 24
25 kV 274ELR-W5X
Use Tables W5 and X1 N5, 10, 18, 24
Replacement
Elbow
15 kV 167RLR-W5X
Use Tables W4 and X1 N5, 11, 13
25 kV 273RLR-W5X
Use Tables W2 and X1 N5, 11, 13
Replacement
Elbow
w/ Test Point
15 kV 168RLR-W5X
Use Tables W4 and X1 N5, 11, 13, 24
25 kV 274RLR-W5X
Use Tables W2 and X1 N5, 11, 13, 24
Direct Test
Elbow
Connector
15 kV 167DLR-W5X
Use Tables W4 and X1 N2, 5, 22
25 kV 273DLR-W5X
Use Tables W2 and X1 N2, 5, 22
Direct Test
Repair Elbow
Connector
15 kV 167DELR-W5X
Use Tables W5 and X1 N5, 10, 18, 22
25 kV 273DELR-W5X
Use Tables W5 and X1 N5, 10, 18, 22
Direct Test
Repair Elbow
Connector
w/ Test Point
15 kV 168DELR-W5X
Use Tables W5 and X1 N5, 10, 18, 22, 24
25 kV 274DELR-W5X
Use Tables W5 and X1 N5, 10, 18, 22, 24
Fused Elbow
(Full Range
Current Limiting)
15 kV
25 kV
168FLR H-W0X
274FLR H-W0X
See Product Guide
PG-PC-H
Bolted Elbow
w/ Tap 15 kV 167LRT-W5X
Use Tables W4 and X1 N17
Bushing Insert
15 kV
25 kV
35 kV
35 kV
1601A4
2701A4
3701A4
3701A3
N4, 8, 20
N4, 8, 20
N6, 21
N8, 21
Extended
Bushing Insert
15 kV
25 kV
1601EA4
2701EA4
N8, 20
N8, 20
Feed-Thru
Insert
15 kV
25 kV
35 kV
1602A3R
2702A1
3702A1
N16
N16
N6, 16
Insulated Cap 15 kV 160DR N9
Insulated Cap
w/ Ground
15 kV
15 kV
25 kV
35 kV
160DRG
167DRG
273DRG
375DRG
N9
N7, 9
N7, 9
N7, 9
N1. Copper lug for use on COPPER CONDUCTOR ONLY.
N2. W5X indicates that the Cat. No. includes 02500X long
bi-metal compression lug as standard. For an
all-copper lug, replace W5X with W2X in Table X1 to
specify the all-copper 02702X lug.
N3. Also available as housing only. Specify: 165BLR-W;
275BLR-W; 375BLR-W; 166BLR-W; 276BLR-W;
376BLR-W.
N4. Also available as elbow/insert combination. Specify:
165A4-WX; 275A4-WX; 166A4-WX; 276A4-WX.
N5. Also available with 200ECS jacket seal included.
Add - “S” suffix to Cat. No.
N6. Rated for single-phase applications only.
N7. Equipped with insulated cuff.
N8. Includes internal torquing feature using 200AT
Assembly Tool.
N9. Also available without probe. Specify “A” suffix -
Example: 273DRGA.
N10.Repair elbow has extended length contact and elbow
housing resulting in a net gain of 3-1/4 in. length.
N11.Replacement elbow has extended length contact and
elbow housing resulting in a net gain of
8-7/8 in. length.
N12.Rated for 25 kV thru 35 kV applications.
N13.Includes long bi-metal contact 00400X.
N14.160CA Cable Size Adapter can only be used with
elbow Cat. No. 165LR/166LR C size only.
N16.Fully rotatable for 360° positioning. Includes bail
assembly to secure feed-thru insert to bushing well.
N17.Includes 02800X bi-metal contact.
N18.Includes 02509X long bi-metal contact.
N19.Includes built-in jacket seal. Also available as
housing only — specify: 165BLRJS-W, 166BLRJS-W,
275BLRJS-W or 276LRJS-W. Also available as
elbow/insert combination — specify: 165JSA4-W5X,
166JSA4-W5X, 275JSA4-W5X or 276JSA4-W5X.
N20. Includes a yellow seating indicator and vent ring.
N21. Includes a black vent ring.
N22. Direct Test Connectors, along with a 200TC-X series
meter adapter, a properly rated voltage meter and
Hot-line Stick provides a means for direct conductor
voltage testing.
N23. With stainless steel bracket.
N24.Test Point Cap Cat# 156-7
Refer to the Wand Xtables on pages A39 to A41 for sizing to cable insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page A30.
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
Insulated Cap
w/ Ground and
Test Point
15 kV 168DRG N7
25 kV 274DRG N7
35 kV 376DRG N7
Grounding Plug
(1/0 AWG x 6’ Ground Lead)
15 kV 161GP
25 kV 272GP
Grounding Elbow
(1/0 AWG x 6’ Ground Lead)
15 kV 160GLR
25/35 kV 370GLR N12
Feed-Thru
15 kV 164FT
25 kV 274FT
35 kV 371FT N16
35 kV 373FT
Feed-Thru
Vertical
15 kV 164FTV
25 kV 274FTV
35 kV 373FTV
Adjustable Bracket
2-point Feed-Thru
15 kV 164FT2-AB N23
25 kV 274FT2-AB N23
35 kV 373FT2-AB N23
Adjustable Bracket
3-point Feed-Thru
15 kV 164FT3-AB N23
25 kV 274FT3-AB N23
35 kV 373FT3-AB N23
Adjustable Bracket
4-point Feed-Thru
15 kV 164FT4-AB N23
25 kV 274FT4-AB N23
35 kV 373FT4-AB N23
Feed-Thru Well 15/25 kV K1601WFT
Feed-Thru Well Vertical 15/25 kV K1601WFTV
Insulated Parking Bushing
15 kV 161SOP N20
25 kV 272SOP N20
35 kV 372SOP N21
15 kV 164SOP N20, 23
25 kV 274SOP N20, 23
Test Rod ALL 370TR
Bushing Well Plug 15/25 kV 276BWP
35 kV M276BWP
Assembly Tool ALL 200AT N8
CONTACTS, PROBES, PLUGS, CABLE
ADAPTERS AND JUNCTIONS
CONTINUED ON PAGE A9.
Elastimold®Cable Accessories
A8
w w w . t n b . c a
200 A Loadbreak
See page A3–A4 for complete information
including switching and fault close
ratings.
Current Ratings
200 A Continuous
10 kA sym., 10 Cycles
Voltage Ratings
15 kV Class
8.3 kV Phase-to-Ground
14.4 kV Phase-to-Phase
95 kV BIL
34 kV AC Withstand
53 kV DC Withstand
11 kV Corona Extinction
25 kV Class
15.2 kV Phase-to-Ground
26.3 kV Phase-to-Phase
125 kV BIL
40 kV AC Withstand
78 kV DC Withstand
19 kV Corona Extinction
35 kV Class
21.1 kV Phase-to-Ground
36.6 kV Phase-to-Phase
150 kV BIL
50 kV AC Withstand
103 kV DC Withstand
26 kV Corona Extinction
Ratings Overview
200 A LOADBREAK SEPARABLE CONNECTOR COMPONENTS
SEE PAGES
A70 TO A 79 FOR
FUSED
ELBOW SELECTION
SEE PAGES
A80 TO A 85 FOR
SURGE ARRESTER
APPLICATIONS
CABLE TO CABLE
CONNECTIONS 4-POINT
JUNCTION
3-POINT
JUNCTION
2-POINT
JUNCTION
LOADBREAK
BUSHING INSERT
LOADBREAK
BUSHING INSERT
LOADBREAK
BUSHING INSERT
2 POINT WELL
JUNCTION
3 POINT WELL
JUNCTION
4 POINT WELL
JUNCTION
Elastimold®Cable Accessories
A9
w w w . t n b . c a
200 A Loadbreak
N1. Repair elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 in. length.
N2. Copper lug for use on COPPER CONDUCTOR ONLY.
N3. Replacement elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 in.length.
N4. 160CA Cable Size Adapter can only be used with elbow part numbers 165LR/166LR C size only.
N5. Also available as rubber only, without straps. Specify suffix “-4” in place of “-5” in the Cat. No.
N6. Supplied with replaceable stud. Replacement stud available separately. Specify 1000-150.
N7. Hardware packages, consisting of brackets and straps only, may be ordered separately by specifying “-6” in the
Cat. No. Example 164J4-6
N8. Hardware package, consists of “U”-straps and back plate only, may be ordered separately by specifying
1601US-J2.
N9. Hardware package, consists of “U”-straps and back plate only, may be ordered separately by specifying
1601US-J3.
N10.Hardware package, consists of “U”-straps and back plate only, may be ordered separately by specifying
1601US-J4.
N11.Hardware package, consists of “U”-straps and back plate only, may be ordered separately by specifying 271-68.
N12.Hardware package, consists of “U”-straps and back plate only, may be ordered separately by specifying 271-61.
N13.Hardware package, consists of “U”-straps and back plate only, may be ordered separately by specifying 271-70.
N14.For use with Direct Test Connectors.
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
Contacts:
Long Bi-Metal
ELR Bi-Metal
Copper
LRT Contact
RLR Contact
ALL
15/25 kV
02702X
02800X
15/25 kV
Use Table X1
02500X
02509X
02702X
02800X
00400X
N1
N2
N3
Elbow Probe
15 kV
25 kV
35 kV
166LRF
274LRF
375LRF
Elbow
Cable Entrance
Insulating Plug
ALL 10EPW
Use Table W6
Cable Size
Adapter 15 kV
160CA-W
Use Table W6
EB-FA Only
N4
Direct Voltage Test
Meter Adapter for:
HD Electric Meters
ALL
200TC-1 N14
Ross Meters 200TC-2 N14
Chance Meters 200TC-4 N14
2-Way Well
Junction w/
s.s. Bracket
15/25 kV K1601WJ2 N6
2-Way Well
Junction w/
“U” Straps
15/25 kV K1601WJ2-5 N5, 6, 11
3-Way Well
Junction w/
s.s. Bracket
15/25 kV K1601WJ3 N6
3-Way Well
Junction w/
“U” Straps
15/25 kV K1601WJ3-5 N5, 6, 12
4-Way Well
Junction w/
s.s. Bracket
15/25 kV K1601WJ4 N6
4-Way Well
Junction w/
“U” Straps
15/25 kV K1601WJ4-5 N5, 6, 13
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
2-Point Junction
with/Stainless
Steel bracket
15 kV
25 kV
35 kV
164J2
274J2
373J2
N7
N7
N7
2-Point Junction
w/“U”-straps
15 kV
25 kV
35 kV
164J2-5
274J2-5
373J2-5
N5, 8
N5, 11
N5, 11
3-Point Junction
with/Stainless
Steel bracket
15 kV
25 kV
35 kV
164J3
274J3
373J3
N7
N7
N7
3-Point Junction
w/“U”-straps
15 kV
25 kV
35 kV
164J3-5
274J3-5
373J3-5
N5, 9
N5, 12
N5, 12
4-Point Junction
with/Stainless
Steel bracket
15 kV
25 kV
35 kV
164J4
274J4
373J4
N7
N7
N7
4-Point Junction
w/“U”-straps
15 kV
25 kV
35 kV
164J4-5
274J4-5
373J4-5
N5, 10
N5, 13
N5, 13
Elastimold®Cable Accessories
A10
w w w . t n b . c a
200 A Deadbreak
200 A deadbreak connectors and accessories provide a quick
disconnect feature for cable and equipment connections on power
distribution systems.
All deadbreak connectors must be DE-ENERGIZED before operating
and must be mechanically secured with bails when connected.
Components can be isolated with insulated caps, plugs and
parking bushings.
All deadbreak elbows are equipped with test points as standard.
Optional accessories allow system grounding, bypass and lightning
surge protection. Additional connecting points and taps can be
provided by use of junctions or feed-thrus.
See page A3–A4 for complete
information including switching
and fault close ratings.
Current Ratings
200 A Continuous
10 kA sym., 10 Cycles
Voltage Ratings
15 kV Class
8.3 kV Phase-to-Ground
14.4 kV Phase-to-Phase
95 kV BIL
34 kV AC Withstand
53 kV DC Withstand
11 kV Corona Extinction
25 kV Class
15.2 kV Phase-to-Ground
26.3 kV Phase-to-Phase
125 kV BIL
40 kV AC Withstand
78 kV DC Withstand
19 kV Corona Extinction
Ratings Overview 200 A DEADBREAK SEPARABLE CONNECTOR COMPONENTS
OPERATING
ACCESSORIES
BUSHING PLUG WELL
CABLE TO EQUIPMENT
INSULATED CAP
EXCEPT FOR LOCKING
SPLICES ALL 200 DEADBREAK
PRODUCTS MUST BE
MECHANICALLY SECURED
WITH A BAIL WHEN CONNECTED
CABLE TO CABLE
CONNECTIONS
STRAIGHT RECEPTACLE
BELOW
CONNECTOR
BUSHING
INSERT
DEADBREAK
FEED-THRU INSERT
INTEGRAL BUSHING
PARKING
STAND
FEED THRU
TEE SPLICE
IN-LINE JUNCTION
STRAIGHT PLUG
INSULATED PLUG
GROUNDING PLUG
STAND-OFF PLUG
4-POINT
JUNCTION
3-POINT
JUNCTION
2-POINT
JUNCTION
LOCKING
“Y” SPLICE
LOCKING AND
REPAIR SPLICE
BUSHING
WELL
SEE PAGES
A80 TO A 85 FOR
SURGE ARRESTER
APPLICATIONS
Elastimold®Cable Accessories
A11
w w w . t n b . c a
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
Elbow Connector
w/ Test Point 15/25 kV 156LR-W5X
Use Tables W4 and X1 N1, 2
Direct Test
Elbow Connector 15/25 kV 156DLR-W5X
Use Tables W4 and X1 N1, 2, 22
Bail Assembly
for 156LR Elbow 15/25 kV 150BA
Bushing Insert 15/25 kV BK1501A1 N3
Feed-thru Insert 15/25 kV K1502A1 N3, 4
Insulated Plug 15/25 kV K150DP N3
Insulated Cap 15/25 kV K150DR N3
Insulated Parking
Bushing 15/25 kV K151SOP N3
Grounding Plug 15/25 kV 151GP N3
Feed-Thru 15/25 kV K1501FT N3, 6
2-Point Junction 15/25 kV K1501J2-U N3, 6
3-Point Junction 15/25 kV K1501J3-U N3, 6
4-Point Junction 15/25 kV K1501J4-U N3, 6
Elbow Probe 15/25 kV 156LRF
Straight
Receptacle 15/25 kV K151SR-W0X
Use Tables W1 and X1 N3, 12, 13, 17, 18
Straight Plug 15/25 kV K151SP-W0X
Use Tables W1 and X1 N3, 12, 13, 19
Tee Splice 15/25 kV K150T N3
In-Line Junction 15/25 kV K150S N3
Locking Splice/
Repair Splice 15/25 kV K151LS-W0X
Use Tables W1A and X1
N8, 9, 13, 15, 16,
17, 20, 23
Locking “Y”
Splice 15/25 kV K151LY-W0X
Use Tables W1A and X1 N8, 9, 13, 15, 17, 21
BAIL 15/25 kV 150TB1 N5
BAIL 15/25 kV 150TB2 N5
BAIL 15/25 kV 150TB3 N5
N1. Includes bail assembly.
N2. W5X indicates that the Cat. No. includes a 02500X bi-metal compression lug, which is rated for either aluminum
or copper conductor, as standard. For an all-copper lug, replace W5X with W2X in Table X1 to specify the
all-copper 02702X lug.
N3. Bails are required but not included. Order separately. Consult factory for bails not listed for a specific application.
N4. Fully rotatable for 360º positioning. Includes bail assembly to secure feed-thru insert to bushing well. Elbows
bail assemblies are required but not included with the feed-thru insert.
N5. Refer to factory for application details.
N6. Center-to-center spacing equals 4 in.
N7. Copper lug for copper cable only.
N8. To order cable legs for different cable sizes, list each leg size “W” and “X”.
Example: K151LY-A1240-A1240-B1220. See Tables W1 and X1 for sizes.
N9. To order locking contacts for K151LS and K151LY, order 01401X (Al) or 01402X (Cu) for plug contact.
Order 01301X (Al) or 01302X (Cu) for receptacle. See Table X1 for sizes.
N10.For use with 156LR elbows.
N11.For use with K151SR, K151SP, K151LS, K151LY receptacles, plugs and splices.
N12.Also available as housing only. Specify K151BSP-W or K151BSR-W.
N13.Also available in EB-FA sizes per table W6 by using 160CA cable adapter with C size plugs and receptacles.
N14.160CA cable adapter can only be used with C size plugs and receptacles.
N15.Bails are not required for locking splices.
N16.When used as a repair splice, the assembled length allows 4 in. for cable replacement/repair.
N17.Straight receptacles are also available with test point. Specify K152SR-W0X Cat. No.
N18.W0X indicates that the Cat. No. includes a 01500X universal aluminum compression lug, which is rated for
either aluminum or copper, as standard. For an all-copper lug, replace W0X with W2X in Table X1 to specify the
all-copper 01502X lug.
N19.W0X indicates that the Cat. No. includes a 01600X universal aluminum compression lug, which is rated for ei
ther aluminum or copper, as standard. For an all-copper lug, replace W0X with W2X in Table X1 to specify the
all-copper 01602X lug.
N20.W0X indicates that the Cat. No. includes a 01400X universal aluminum compression lug, which is rated for ei
ther aluminum or copper, as standard. For an all-copper lug, replace W0X with W2X in Table X1 to specify the
all-copper 01402X lug.
N21.W0X indicates that the Cat. No. includes a 01300X universal aluminum compression lug, which is rated for ei
ther aluminum or copper, as standard. For an all-copper lug, replace W0X with W2X in Table X1 to specify the
all-copper 01302X lug.
N22.Direct Test Connectors, along with a 200TC-X series meter adapter, a properly rated voltage meter and Hot-line
Stick provides a means for direct conductor voltage testing. See page A13 for meter adapters.
N23.Gains approximately 4 in. of repair length.
Refer to the Wand Xtables on pages A39 to A41 for sizing to cable insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page A30.
200 A Deadbreak
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
BAIL 15/25 kV 150TB4 N5
BAIL 15/25 kV 150TB5 N5
Contacts:
Long Bi-Metal
Copper
15/25 kV
15/25 kV
02500X
02702X N7
Elbow
Cable Entrance
Insulating Plug
15/25 kV 10EP-W
Use Table W6 N10
Cable Entrance
Insulating Plug 15/25 kV 152EA-W
Use Table W6 N11
Cable Size
Adapter 15/25 KV
160CA-W
Use Table W6
EB-FA Only
N14
Elastimold®Cable Accessories
A12
w w w . t n b . c a
600 Series Deadbreak
600 Series deadbreak elbows, straight receptacles, junctions, vault
stretchers and accessories are used to connect equipment and cable
on primary feeder and network circuits. Designs accommodate large
conductors and feature bolted connections and deadfront modular
construction for maximum reliability, performance and versatility.
DE-ENERGIZED connectors can be quickly and easily connected and
disconnected using standard hand tools and equipment in accordance
with accepted operating practices. Optional accessories allow visible
external separation, by-pass, isolation, dead-ending, grounding, and
testing as well as adding taps, surge arresters and circuit protection.
Hotstick operable and separable joint systems are shown
on pages A16 thru A21.
See page A3–A4 for complete
information.
Current Ratings
(Prefixes: 650, K650, K655, K656,
750, 755, 756 and 03700)
600 A Continuous
25 kA sym., 10 cycles
(Prefixes 675, K675, K676,
775, 776 and 03702)
900 A Continuous
25 kA sym., 10 cycles
Note: 900 A ratings require copper cable and copper
current-carrying components.
VOLTAGE RATINGS
15/25 kV Class (5 kV thru 28 kV)
16.2 kV Phase-to-Ground
28 kV Phase-to Phase
140 kV BIL
45 kV AC Withstand
84 kV DC Withstand
21.5 kV Corona Extinction
35 kV Class
21.1 kV Phase-to-Ground
36.6 kV Phase-to-Phase
150 kV BIL
50 kV AC Withstand
103 kV DC Withstand
26 kV Corona Extinction
Note: Elastimold has increased the IEEE Standard
Prod uction and Design Test levels for 25 kV Class
products to include 27 kV and 28 kV systems.
Ratings Overview SEPARABLE CONNECTORS 600 SERIES DEADBREAK
CABLE TO CABLE
UTILIZING-KITS
STRAIGHT RECEPTACLE
SEE PAGES A80 TO A 85
FOR SURGE ARRESTERS
APPLICATIONS
ELBOW CONNECTOR
600 SERIES
TAPS
CABLE TO EQUIPMENT
CABLE TO CABLE
(UTILIZING JUNCTION)
SEE PAGES A22 AND A23
FOR ADDITIONAL
JUNCTIONS
INTEGRAL
BUSHING
THREADED
STUD BUSHING
EXTENDER
CONNECTING
PLUG
4 PT JUNCTION
3 PT JUNCTION
2 PT JUNCTION
OPERATING
ACCESSORIES
GROUNDING
PLUG
INSULATED
PARKING
BUSHING
HOTSTICK OPERABLE 600 SERIES
CONNECTORS – SEE PAGES A16-A19
STICK-OP
SEE PAGES.
A18 & A19
THREADED
COMPRESSION LUG
STICK-OP LOADBREAK
REDUCING TAP PLUG LINK-OP
SEE PAGES
A16 & A17
LINK CONNECTOR
LINK-OP
CAM-OP
LINK CONNECTOR
CAM-OP
RETAINER SLEEVES
CAM-OP
SEE PAGES A16 & A17
LINK-OP
RETAINER
SLEEVES
STRAIGHT RECEPTACLE
ADAPTER BOLT &
WASHERS
STRAIGHT
RECEPTACLE
HOUSING
RETAINING
RING
CABLE
ADAPTER
200A TAPS
200A DEADBREAK
SEE PAGES A10 & A11
DEADBREAK
REDUCING
TAP PLUG
LOADBREAK
ELBOW TAP PLUG
REDUCING TAP
WELL
SPANNER WRENCH
200 A DEADBREAK
SEE PAGES A6 & A7
WINDOW-OP
SEE PAGES A18 & A19
CABLE TO CABLE
UTILIZING
VAULT
STRETCHERS
L-4
L-3
L-2
L-1
VS2
VS3
VS4
COMPRESSION
LUG
CABLE
ADAPTER
COMPRESSION
LUG
VAULT
STRETCHER
THREADED
STUD
VAULT
STRETCHER
CONNECTOR
COMPRESSION
LUG
CABLE
ADAPTER
INSULATED CAP
WITH TEST POINT
BUSHING
EXTENDER
THREADED
STUD
CABLE
ADAPTER
COMPRESSION
LUG
600
SERIES
ELBOW
THREADED
STUD
CONNECTING
PLUG
VOLTAGE
DETECTION
CAP
INSULATING
PLUG
SEE PAGE A14 & A15
SEE PAGE A14 & A15
Elastimold®Cable Accessories
A13
w w w . t n b . c a
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
600 Series Elbow
(w/ Insul. Plug, Cap, Stud,
Lug and Cable Adapter)
15/25 kV
35 kV
K655LR-W0X
Use Tables W7 and X6
755LR-W0X
Use Tables W9 and X6
N1, 2, 12
N1, 2, 12
600 Series Direct
Test Elbow
(w/ Insul. Plug, Cap, Stud
Lug and Cable Adapter)
15/25 kV
35 kV
K655DLR-W0X
755DLR-W0X
N1, 2, 12, 14
N1, 2, 12, 14
600 Series Elbow
w/ Test Point
(w/ Insul. Plug, Cap, Stud
Lug and Cable Adapter)
15/25 kV
35 kV
K656LR-W0X
Use Tables W7 and X6
756LR-W0X
Use Tables W9 and X6
N1, 2, 12
N1, 2, 12
600 Series Direct
Test Elbow w/Test Point
(w/ Insul. Plug, Cap, Stud,
Lug and Cable Adapter)
15/25 kV
35 kV
K656DLR-W0X
Use Tables W7 and X6
756DLR-W0X
Use Tables W9 and X6
N1, 2, 12, 14
N1, 2, 12, 14
600 Series Elbow
Housing only
(w/ Stud)
15/25 kV
35 kV
K655BLR
755BLR
N1, 3
N1, 3
600 Series Elbow
w/ Test Point
Housing only
(w/ Stud)
15/25 kV
35 kV
K656BLR
756BLR
N1, 3
N1, 3
600 Series
Replacement Elbow
Housing only
w/o Test Point
15/25 kV K655BRLR N16
600 Series
Replacement Elbow
Housing only
w/o Test Point
15/25 kV K656BRLR N16
600 Series Straight
Receptacle
(w/ Cable
Adapter, Lug and
Retaining Ring)
15/25 kV K655SR-W0X
Use Tables W7 and X6 N1 ,2, 11
600 Series Direct
Test Straight
Receptacle
Elbow
15/25 kV K655DSR-W0X
Use Tables W7 and X6 N1, 2, 11, 14
600 Series Straight
Receptacle Housing
(Lug and Cable
Adapter not included)
15/25 kV K655BSR N1, 11
Straight Receptacle
Adapter 15/25 kV K650SRA N1, 4
600 Series
Vault Stretcher
(Housing only
15/25 kV
35 kV
K655BVS
755BVS
N1, 9
N1, 9
Cable Size
Adapter
15/25 kV
35 kV
655CA-W
Use Table W7
755CA-W
Use Table W9
Compression
Lug
ALL
ALL
03700X
Use Table X6
03702X
Use Table X6
N5
N6
600 Series Elbow
and Vault Stretcher
Size Sensitive Kit
(Cable Adapter
and Lug)
15/25 kV
35 kV
655CK-W0X
Use Tables W7 and X6
755CK-W0X
Use Tables W9 and X6
N2
N2
Adapter
Retaining Ring ALL 650ARR-X
Use Table X6
600 Series Deadbreak
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
600 Series Straight
Receptacle Size
Sensitive Kit (Cable
Adapter, Retaining
Ring and Lug)
15/25 kV 655CK-W0X-ARR
Use Tables W7 and X6 N2
Bushing Extender
(w/ Stud)
15/25 kV
35 kV
K655BE
755BE
N1, 3
N1, 3
Insulated Cap
w/ Test Point (w/ Stud) 15/25 kV K656DR N3, 7
Insulated Cap
w/ Test Point
(w/ Stud and Ground)
15/25 kV K656DRG N3, 7
Insulating Plug
(w/ Cap)
15/25 kV
35 kV
K650BIP
750BIP
N1, 7, 8
N1, 7, 8
Grounding Plug
(Ground Lead
2/0 AWG x 30 in.)
15/25 kV
35 kV
650GP
750GP
N1, 7, 8
N1, 7, 8
Insulated
Parking Bushing
15/25 kV
35 kV
K650SOP
750SOP
N7, 8
N7, 8
Connecting Plug
15/25 kV
15/25 kV
35 kV
K650CP
K651CP
750CP
N1, 7, 8, 9, 13
N1, 7, 8, 10
N1, 7, 8, 10
Deadbreak
Reducing
Tap Plug
15/25 kV K650RTP N1, 7, 8, 9
Reducing Tap Well 15/25 kV K650RTW N1, 7, 8, 9
Loadbreak
Elbow
Tap Plug
15 kV
25 kV
35 kV
650ETP
K650ETP
750ETP
N1, 7, 8, 10, 12
N1, 7, 8, 10, 12
N1, 7, 8, 10, 12
Vault Stretcher
Threaded Stud
15/25 kV
35 kV
650VSA
750VSA
N1
N1
600 Series Elbow
Threaded Stud
15/25 kV
35 kV
650SA
750SA
N1
N1
Assembly Tool
(Window-Op) ALL 600ATM N12
Spanner Wrench ALL 600SW N9
Direct Voltage Test
Meter Adapter for:
HD Electric Meters
ALL
200TC-1 N14
Ross Meters 200TC-2 N14
Chance Meters 200TC-4 N14
N1. For 900 A ratings, substitute 675 for 650 and 655; 676 for 656; K671 for K651; K675 for K650 and K655; K676
for K656; 775 for 750 and 755; 776 for 756 and 2X for 0X in the Cat. No. The 900 A rating requires copper
current-carrying connector components and copper conductor cable.
N2. Add suffix symbol from page A29 to include cable shield grounding kit and/or cable jacket sealing kit.
N3. Available without the stud by adding “N” to the Cat. No.
N4. Straight Receptacle Adapter is used to connect Straight Receptacles K655YBSR and K655YSR-W0X
(Page A19) to equipment bushings.
N5. Aluminum lug for use on aluminum or copper conductors. DO NOT substitute threaded 03600X lug.
N6. Copper lug for use on COPPER CONDUCTOR ONLY. DO NOT substitute threaded 03602X lug.
N7. Available with the stud factory-assembled by adding “SP” to the Cat. No. 675ETP, K675ETP and 775ETP are
available as -SP only. The stud is not field removable.
N8. Available with a loose stud by adding suffix “S” to the Cat. No.
N9. 600SW spanner wrench is recommended for installation of K650CP connecting plug, deadbreak reducing tap
plugs and reducing tap wells.
N10.Use 600ATM Assembly Tool.
N11.600 Series Elbows and Straight Receptacles with IEEE Std. 386 capacitive test points are available by
substituting 656 for 655; K656 for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and
776 for 775 in the Cat. No.
N12.See page A17 for Window-Op Connector Kit.
N13.Superseded by K651CP.
N14.Direct Test Connectors, along with a 200TC-X series meter adapter, a properly rated voltage meter and Hot-line
Stick; provides a means for direct conductor voltage testing.
N15.With stainless steel bracket.
N16.Replacement Elbow includes an I-Adapter, and Straight Receptacle, resulting in a net gain of 20 in.
Refer to the Wand Xtables on pages A39 to A41 for sizing to cable insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page A30.
Elastimold®Cable Accessories
A14
w w w . t n b . c a
600 Series Deadbreak
600 Series deadbreak elbows, straight receptacles, junctions, vault
stretchers and accessories are used to connect equipment and cable
on primary feeder and network circuits. Designs accommodate large
conductors and feature bolted connections and deadfront modular
construction for maximum reliability, performance and versatility.
DE-ENERGIZED connectors can be quickly and easily connected and
disconnected using standard hand tools and equipment in accordance
with accepted operating practices. Optional accessories allow visible
external separation, by-pass, isolation, dead-ending, grounding, and
testing as well as adding taps, surge arresters and circuit protection.
Hotstick operable and separable joint systems are shown on
pages A16 thru A21.
See page A3–A4 for complete
information.
Current Ratings
(Prefixes: 650, K650, K655,
K656, 750, 755, 756 and 03700)
600 A Continuous
25 kA sym., 10 cycles
(Prefixes 675, K675, K676,
775, 776 and 03702)
900 A Continuous
25 kA sym., 10 cycles
NOTE: 900 A ratings require copper cable and cop-
per current-carrying components.
Voltage Ratings
15/25 kV Class (5 kV thru 28 kV)
16.2 kV Phase-to-Ground
28 kV Phase-to-Phase
140 kV BIL
45 kV AC Withstand
84 kV DC Withstand
21.5 kV Corona Extinction
35 kV Class
21.1 kV Phase-to-Ground
36.6 kV Phase-to-Phase
150 kV BIL
50 kV AC Withstand
103 kV DC Withstand
26 kV Corona Extinction
Note: Elastimold has increased the IEEE Standard
Prod uction and Design Test levels for 25 kV Class
products to include 27 kV and 28 kV systems.
Ratings Overview SEPARABLE CONNECTORS 600 SERIES DEADBREAK
CABLE TO CABLE
UTILIZING-KITS
STRAIGHT RECEPTACLE
SEE PAGES A 80 TO A 85
FOR SURGE ARRESTERS
APPLICATIONS
ELBOW CONNECTOR
600 SERIES
TAPS
CABLE TO EQUIPMENT
CABLE TO CABLE
(UTILIZING JUNCTION)
INTEGRAL
BUSHING
THREADED
STUD BUSHING
EXTENDER
CONNECTING
PLUG
4 PT JUNCTION
3 PT JUNCTION
2 PT JUNCTION
OPERATING
ACCESSORIES
GROUNDING
PLUG
INSULATED
PARKING
BUSHING
HOTSTICK OPERABLE 600 SERIES
CONNECTORS – SEE PAGES 14 - 17 STICK-OP
SEE PAGES 16 & 17
THREADED
COMPRESSION LUG
STICK-OP LOADBREAK
REDUCING TAP PLUG
LINK-OP
SEE PAGES
14 & 15
LINK CONNECTOR
LINK-OP
CAM-OP
LINK CONNECTOR
CAM-OP
RETAINER SLEEVES
CAM-OP
SEE PAGES 14 & 15
LINK-OP
RETAINER
SLEEVES
STRAIGHT RECEPTACLE
ADAPTER
BOLT &
WASHERS
STRAIGHT
RECEPTACLE
HOUSING
RETAINING
RING
CABLE
ADAPTER
200A TAPS
200A DEADBREAK
SEE PAGES 8 & 9
DEADBREAK
REDUCING TAP
PLUG
LOADBREAK
ELBOW TAP PLUG
REDUCING TAP
WELL
SPANNER WRENCH
200A DEADBREAK
SEE PAGES 4 & 5
WINDOW-OP
SEE PAGES 16 & 17
CABLE TO CABLE
UTILIZING
VAULT
STRETCHERS
L-4
L-3
L-2
L-1
VS2
VS3
VS4
COMPRESSION
LUG
CABLE
ADAPTER
COMPRESSION
LUG
VAULT
STRETCHER
THREADED
STUD
VAULT
STRETCHER
CONNECTOR
COMPRESSION
LUG
CABLE
ADAPTER
INSULATED CAP
WITH TEST POINT
BUSHING
EXTENDER
THREADED
STUD
CABLE
ADAPTER
COMPRESSION
LUG
600
SERIES
ELBOW
THREADED
STUD
CONNECTING
PLUG
VOLTAGE
DETECTION
CAP
INSULATING
PLUG
Elastimold®Cable Accessories
A15
w w w . t n b . c a
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
2-Point Junction 15/25 kV
35 kV
K650J2
750J2
N1, 9, 10
N1, 9, 10
3-Point Junction 15/25 kV
35 kV
K650J3
750J3
N1, 9, 10
N1, 9, 10
4-Point Junction 15/25 kV
35 kV
K650J4
750J4
N1, 9, 10
N1, 9, 10
1-way
L-Kit
15/25 kV
35 kV
K655L1
755L1
N1, 2, 3, 4
N1, 2, 3, 4
2-way
L-Kit
15/25 kV
35 kV
K655L2
755L2
N1, 2, 3, 4, 5, 6, 7
N1, 2, 3, 4, 5, 6, 7
2-way
VS-Kit
15/25 kV
35 kV
K655VSL2
755VSL2
N1, 2, 3
N1, 2, 3
3-way
L-Kit
15/25 kV
35 kV
K655L3
755L3
N1, 2, 3, 4, 5
N1, 2, 3, 4, 5
3-Way
VS Kit
15/25 kV
35 kV
K655VSL3
755VSL3
N1, 2, 3, 5, 6, 7
N1, 2, 3, 5, 6, 7
4-Way
L-Kit
15/25 kV
35 kV
K655L4
755L4
N1, 2, 3, 4, 5
N1, 2, 3, 4, 5
4-Way
VS-Kit
15/25 kV
35 kV
K655VSL4
755VSL4
N1, 2, 3, 5
N1, 2, 3, 5
Assembly Tool
(Window-Op) ALL 600ATM N8
Spanner Wrench ALL 600SW N2
600 Series Deadbreak
N1. For 900 A ratings, substitute 675 for 650 and 655; 676 for 656; K675 for K650 and K655; K676 for K656; 775
for 750 and 755; 776 for 756 and 2X for 0X in the Cat. No. The 900 A rating requires copper current-carrying
connector components and copper conductor cable.
N2. 600SW spanner wrench is recommended for installation of K650CP connecting plug, deadbreak reducing tap
plugs and reducing tap wells.
N3. L-Kits and VS-Kits do not include cable adapters or compression lugs. These items must be ordered separately.
N4. 600 Series Elbows and Straight Receptacles with IEEE Std. 386 capacitive test points are available by
substituting 656 for 655; K656 for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and 776 for
775 in the Cat. No.
N5. 600ATM is recommended for installing K651CP and 750CP.
N6. Can be used as a repair joint. (Gains 3-1/2 in. of repair length)
N7. Can be used as a reducing joint for different size cables.
N8. See page A17 for Window-Op Connector Kit.
N9. Rubber junction with stainless steel mounting plate and back plate.
Add “-U” for rubber junction with stainless steel mounting plate, back plate and adjustable mounting bracket.
Add “-4” for rubber junction only.
Add “-5” for rubber junction, stainless steel U-straps and back plate.
N10.Two - six-position multi-point junctions shown on pages A20 and A21.
VAULT STRETCHER
Provides an alternate method of splicing and joining
various types and styles of cables using standard
600 Series components.
Refer to the Wand Xtables on pages A39 to A41 for sizing to cable insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page A30.
Elastimold®Cable Accessories
A16
w w w . t n b . c a
Elastimold®600 Series Cam-Op, and Link-Opdeadbreak
connector systems incorporate provisions for hotstick operation of
DE-ENERGIZED primary feeder or network circuits. Configurations allow
external visible break, testing, grounding and isolation. Retrofit kits allow
upgrading existing equipment.
Cam-Op systems utilize pin and socket connectors. Link-Op connectors
are bolted and installed using torque controlled tools. Either system can
be retrofitted to existing equipment.
The Cam-Op and Link-Op connectors are unique, allowing all hotstick
operations to be completed without moving the cable, an important
consideration when large, stiff cables prohibit movement.
The Cam-Op connector is easily installed or removed by hotstick
operation of the cam action disconnect lever.
See page A3–A4 for complete
information.
Current Ratings
600 and 900 A Continuous
25 kA sym., 10 cycles
NOTE: 900 A ratings require copper cable and
copper current-carrying components.
Voltage Ratings
15 kV Class
8.3 kV Phase-to-Ground
14.4 kV Phase-to-Phase
95 kV BIL
34 kV AC Withstand
53 kV DC Withstand
11 kV Corona Extinction
25 kV Class
15.2 kV Phase-to-Ground
26.3 kV Phase-to-Phase
125 kV BIL
40 kV AC Withstand
78 kV DC Withstand
19 kV Corona Extinction
35 kV Class
21.1 kV Phase-to-Ground
36.6 kV Phase-to-Phase
150 kV BIL
50 kV AC Withstand
103 kV DC Withstand
26 kV Corona Extinction
CAM-OPand LINK-OPSYSTEM – 600 SERIES DEADBREAK
RETROFIT COMPONENTS FOR
EXISTING EQUIPMENT W/O
PROVISIONS FOR MOUNTABLE
INSULATED BUSHING
CABLE TO EQUIPMENT
EQUIPMENT
BUSHING
SEE PAGES A 80 TO A 85
FOR SURGE ARRESTER
APPLICATIONS
600 Series Deadbreak – Cam-Op, Link-Op
CAM-OP
INSULATED
PARKING
BUSHING
OR
OR OR OR
OR
OR
OR
OR
ALIGNMENT
BRACKET
LINK-OP
CAM-OP
LINK-OP
EQUIPMENT
BUSHING
MOUNTABLE INSULATED
PARKING BUSHING
ALIGNMENT
BRACKET
600 SERIES
ELBOW
CAM-OP
LINK-OP
RETAINER
SLEEVES LINK CONNECTOR
INSULATED
CAP
LOADBREAK
ELBOW CONNECTOR
ELBOW
ARRESTER
COMPRESSION
LUG
CABLE
ADAPTER
ELBOW
ARRESTER
LOADBREAK
ELBOW CONNECTOR
INSULATED
CAP
LINK
CONNECTOR
CAM-OP LINK-OP
RETAINER
SLEEVES
CABLE
ADAPTER
COMPRESSION
LUG
600 SERIES
ELBOW
600 SERIES
ELBOW
COMPRESSION
LUG
CABLE
ADAPTER
OPERATING TOOL
GROUNDING
ELBOW
TEST ROD
CAM-OP
LINK-OP
LOADBREAK
ELBOW TAP LUG
CABLE TO CABLE CONNECTION
CAM-OP LINK-OP
2-POINT
NSULATED
BUSHINGS
BUSHING
EXTENDER
Ratings Overview
Elastimold®Cable Accessories
A17
w w w . t n b . c a
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
CAM-OP
CONNECTOR
KIT
15 kV
25 kV
35 kV
655LINK-C-LR-W0X-B-DRG
Use Tables W7 and X6
K655LINK-C-LR-W0X-B-DRG
Use Tables W7 and X6
755LINK-C-LR-W0X-B-DRG
Use Tables W9 and X6
N1, 3, 11,
13, 14, 18
N1, 3, 11,
13, 14, 18
N1, 3, 11,
13, 14, 18
LINK-OP
CONNECTOR
KIT
15 kV
25 kV
35 kV
655LINK-B-LR-W0X-B-DRG
Use Tables W7 and X6
K655LINK-B-LR-W0X-B-DRG
Use Tables W7 and X6
755LINK-B-LR-W0X-B-DRG
Use Tables W9 and X6
N2, 3, 11, 12
13, 14, 18
N2, 3, 11,
13, 14, 18
N2, 3, 11,
13, 14, 18
Mountable
Insulated
Bushing
25 kV
35 kV
K650LBM-3
750LBM-3
N3
N3
RETROFIT
CAM-OP
CONNECTOR
KIT
15 kV
25 kV
35 kV
655LINK-C-LR-W0X-A-DRG
Use Tables W7 and X6
K655LINK-C-LR-W0X-A-DRG
Use Tables W7 and X6
755LINK-C-LR-W0X-A-DRG
Use Tables W9 and X6
N5, 11, 13
14, 18
N5, 11, 13
14, 18
N5, 11, 13
14, 18
RETROFIT
LINK-OP
CONNECTOR
KIT
15 kV
25 kV
35 kV
655LINK-B-LR-W0X-A-DRG
Use Tables W7 and X6
K655LINK-B-LR-W0X-A-DRG
Use Tables W7 and X6
755LINK-B-LR-W0X-A-DRG
Use Tables W9 and X6
N6, 11, 12,
13, 14, 18|
N6, 11, 12,
13, 14, 18
N6, 11, 12,
13, 14, 18
Insulating
Plug
25 kV
35 kV
K650LB
750LB
N4
N4
CAM-OP
Alignment
Bracket
15 kV
25 kV
35 kV
650CAB
K650CAB
750CAB
LINK-OP
Alignment
Bracket (Retrofit
LINK-OP Only)
ALL
ALL
650AB
650ABV
N15
N15
Compression
Lug
ALL
ALL
03700X
Use Table X6
03702X
Use Table X6
N7
N8
CAM-OP and
LINK-OP Size
Sensitive Kit
(Cable Adapter
and Lug)
15/25 kV
35 kV
655CK-W0X
Use Tables W7 and X6
755CK-W0X
Use Tables W9 and X6
N13
N13
CAM-OP
Retaining Sleeve ALL 650RSC N11
LINK-OP
Retaining Sleeve ALL 650RS N11
CAM-OP
CABLE JOINT
KIT
15 kV
25 kV
35 kV
655BI-LINK-C-LR-WOX-DRG
Use Tables W7 and X6
K655BI-LINK-C-LR-WOX-DRG
Use Tables W7 and X6
755BI-LINK-C-LR-WOX-DRG
Use Tables W9 and X6
N9, 11, 13
14, 18
N9, 11, 13
14, 18
N9, 11, 13
14, 18
LINK-OP
CABLE JOINT
KIT
15 kV
25 kV
35 kV
655BI-LINK-B-LR-WOX-DRG
Use Tables W7 and X6
K655BI-LINK-B-LR-WOX-DRG
Use Tables W7 and X6
755BI-LINK-B-LR-WOX-DRG
Use Tables W9 and X6
N10, 11, 12,
13, 14, 18
N10, 11, 12,
13, 14, 18
N10, 11, 12,
13, 14, 18
600 Series Deadbreak – Cam-Op, Link-Op
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
CAM-OP
Loadbreak
Reducing
Tap Plugs
(Visi-Break)
15 kV
25 kV
35 kV
650LK-C-VB
K650LK-C-VB
750LK-C-VB
CAM-OP
LINK
15 kV
25 kV
35 kV
650LK-C
K650LK-C
750LK-C
LINK-OP
Loadbreak
Reducing
Tap Plug
15 kV
25 kV
35 kV
650LT-B
K650LT-B
750LT-B
N11
Grounding
Elbow
(1/0 AWG x 6’
Ground Lead)
15 kV
25 kV
35 kV
160GLR
370GLR
370GLR
N19
N19
Test Rod ALL 370TR
Assembly Tool ALL 600AT N11
Cam-Op
Operating
Kit
15 kV
25 kV
35 kV
650CAM-OK
K650CAM-OK
750CAM-OK
N16
N16
N16
Link-Op
Operating
Kit
15 kV
25 kV
35 kV
650LINK-OK
K650LINK-OK
750LINK-OK
N17
N17
N17
N1. Cam-Op connector kit includes: 1- Cam-Op link; 1- elbow housing; 1- cable adapter; 1-0370 style lug;
1- bushing extender;
2- retainer sleeves; 1- insulated cap; 1- mountable insulated bushing and 1- alignment bracket.
N2. Link-Op connector kit includes: 1- Link-Op link; 1- elbow housing; 1- cable adapter; 1-0370 style lug;
1- bushing extender; 2- retainer sleeves; 2- insulated caps; and 1- mountable insulated bushing.
N3. Mountable insulated bushing included with Cam-Op and Link-Op connector kit. Requires 3 threaded studs on
equipment faceplate for installation.
N4. Use with the Retrofit Cam-Op and Retrofit Link-Op connector kit.
N5. Retrofit Cam-Op connector kit includes: 1- link; 1- elbow housing; 1- cable adapter; 1-0370 style lug;
1- bushing extender; 2- retainer sleeves; 1- insulated cap; 1- insulating plug; and 1- alignment bracket.
N6. Retrofit Link-Op connector kit includes: 1- link; 1- elbow housing; 1- cable adapter; 1-0370 style lug;
1- bushing extender; 2- retainer sleeves; 2- insulated caps; 1- insulating plug; and 1- alignment bracket.
N7. Aluminum lug for use on aluminum or copper conductors. DO NOT substitute threaded 03600X lug
N8. Copper lug for use on COPPER CONDUCTOR ONLY. DO NOT substitute 03602X threaded lug.
N9. Cam-Op Cable Joint Kit includes: 1- Cam-Op link; 1- Cam-Op BI-SOP; 2- elbow housings; 2- cable adapters; 2-
0370 style lugs; 2- retainer sleeves; 1- insulated cap.
N10.Link-Op Cable Joint Kit includes: 1- Link-Op link; 1- Link-Op BI-SOP; 2- elbow housings; 2- cable adapters;
2- 0370 style lugs; 2- retainer sleeves; 2- insulated caps.
N11.600AT assembly tool required for operation and/or installation of Link-Op. 600ATM is recommended
for installing Link-Op/Cam-Op retaining sleeves.
N12.For 900 A ratings, substitute 675 for 650 and 655; 676 for 656; K675 for K650 and K655; K676 for K656; 775
for 750 and 755; 776 for 756 and 2X for 0X in the Cat. No. The 900 A rating requires copper current-carrying
connector components and copper conductor cable.
N13.Add suffix symbol from page A29 to include cable shield grounding kit and/or cable jacket sealing kit.
N14.To add elbows or arresters instead of insulating caps, replace the “DRG” with “LR-WX” for elbows (with test
point) or “ESA” for elbow arresters.
N15.The 650ABV is required when the bushing horizontal spacing on the equipment or junctions is less than 5".
N16.Cam-Op operating kit includes accessories that enable visible break, testing, isolation and grounding functions
to be performed. Kit includes: 3- Cam-Op loadbreak reducing tap plugs; 3- grounding elbows; 1- assembly tool;
1- test rod; 1- carry case; 1- lubricant; 1- instructions.
N17.Link-Op operating kit includes accessories that enable visible break, testing, isolation and grounding functions
to be performed. Kit includes: 6- Link-Op loadbreak reducing tap plugs; 3- grounding elbows; 1- assembly tool;
1- test rod; 1- carry case; 1- lubricant; 1- instructions.
N18.600 Series Elbows and Straight Receptacles with IEEE Std. 386 capacitive test points are available by
substituting 656 for 655; K656 for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and 776 for
775 in the Cat. No.
N19. Rated for both 25 kV and 35 kV applications.
Refer to the Wand Xtables on pages A39 to A41 for sizing to cable insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page A30.
AB ABV
Elastimold®Cable Accessories
A18
w w w . t n b . c a
Elastimold®600 Series Window-Opand Stick-Opdeadbreak
connector systems incorporate provisions for hotstick operation of
DE-ENERGIZED primary feeder or network circuits.
The Window-Op and Stick-Op connectors allow direct testing and
grounding with no required cable movement.
Window-Op is ideal for equipment applications which include viewing
windows to provide an internal visible break that does not require
hotstick removal of the elbows.
Stick-Op provides an external visible break by hotstick removal of
the elbow.
Window-Op and Stick-Op connectors are bolted and installed using
torque controlled tools.
See page A3–A4 for complete
information.
Current Ratings
600 and 900 A Continuous
25 kA sym., 10 cycles
NOTE: 900 A ratings require copper cable and
copper current-carrying components.
Continuous
Voltage Ratings
15 kV Class
8.3 kV Phase-to-Ground
14.4 kV Phase-to-Phase
95 kV BIL
34 kV AC Withstand
53 kV DC Withstand
11 kV Corona Extinction
25 kV Class
15.2 kV Phase-to-Ground
26.3 kV Phase-to-Phase
125 kV BIL
40 kV AC Withstand
78 kV DC Withstand
19 kV Corona Extinction
35 kV Class
21.1 kV Phase-to-Ground
36.6 kV Phase-to-Phase
150 kV BIL
50 kV AC Withstand
103 kV DC Withstand
26 kV Corona Extinction
STICK-OPand WINDOW-OPSYSTEM – 600 SERIES DEADBREAK
SEE PAGES A80 TO A 85
FOR SURGE ARRESTER
APPLICATIONS
600 Series Deadbreak – Stick-Op,
Window-Op
TEST ROD
INSULATED
CAP
BOLTED CONNECTION
LOADBREAK REDUCING
TAP PLUG
STICK-OP LRTP
LOADBREAK
TAP PLUG
INTEGRAL
BUSHING
WINDOW-OP ETP
ELBOW TAP PLUG
INSULATED CAP
600 SERIES
ELBOW
THREADED
COMPRESSION LUG
STICK-OP
OR
COMPRESSION LUG
WINDOW-OP
CABLE ADAPTER
STICK-OP
600BD/200LB
BUSHING/ELBOW
ADAPTER
OPERATING ACCESSORIES
GROUNDING
PLUG
STAND-OFF
PLUG ASSEMBLY TOOL
(WINDOW-OP)
ASSEMBLY TOOL
(STICK-OP)
GROUNDING
ELBOW
Ratings Overview
Elastimold®Cable Accessories
A19
w w w . t n b . c a
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
WINDOW-OP
Connector Kit
15 kV
25 kV
35 kV
655ETP-W0X-DRG
Use Tables W7 and X6
K655ETP-W0X-DRG
Use Tables W7 and X6
755ETP-W0X-DRG
Use Tables W9 and X6
N1, 4, 5, 6
13, 15
WINDOW-OP
Replacement
Connector Kit
15 kV
25 kV
655RETP
K655RETP
N4, 5, 6
8, 13
STICK-OP
Connector Kit
15 kV
25 kV
35 kV
655LRTP-W0X-DRG
Use Tables W7 and X6
K655LRTP-W0X-DRG
Use Tables W7 and X6
755LRTP-W0X-DRG
Use Tables W9 and X6
N2 ,3, 4, 5,
8, 13
STICK-OP
Replacement
Connector Kit
15 kV
25 kV
655RLRTP
K655RLRTP
N3, 4, 5
8, 13, 16
WINDOW-OP
Loadbreak
Elbow
Tap Plug
15 kV
25 kV
35 kV
650ETP
K650ETP
750ETP
N4, 15
N4, 15
N4, 15
STICK-OP
Loadbreak
Reducing
Tap Plug
15 kV
25 kV
35 kV
650LRTPA3
K650LRTPA2
750LRTPA2
N3,4
STICK-OP
Bushing
Adapter
15 kV
25 kV
35 kV
655BEA3
K655BEA2
755BEA2
N3,4
Compression
Lug
WINDOW-OP
ALL
ALL
03700X
Use Tables X6
03702X
Use Tables X6
N6
N7
Threaded
Compression
Lug
STICK-OP
ALL
ALL
03600X
Use Tables X6
03602X
Use Tables X6
N8
N9
WINDOW-OP
Size Sensitive Kit
(Cable Adapter
and Lug)
15/25 kV
35 kV
655CK-W0X
Use Tables W7 and X6
755CK-W0X
Use Tables W9 and X6
N5
N5
STICK-OP
Size Sensitive Kit
(Cable Adapter
and Threaded Lug)
15/25 kV
35 kV
655TCK-W0X
Use Tables W7 and X6
755TCK-W0X
Use Tables W9 and X6
N5
N5
Extraction Tool ALL 650ET N10
Grounding
Elbow
(1/0 AWG x 6’
Ground Lead)
15 kV
25 kV
35 kV
160GLR
370GLR
370GLR
N14
N14
Test Rod ALL 370TR
Assembly Tool
(Stick-Op) ALL 600AT N3
Assembly Tool
(Window-Op) ALL 600ATM N15
STICK-Op
Operating
Kit
15 kV
25 kV
35 kV
650STICK-OK
K650STICK-OK
750STICK-OK
N11
N11
N11
WINDOW-Op
Operating
Kit
15 kV
25 kV
35 kV
650WINDOW-OK
K650WINDOW-OK
750WINDOW-OK
N12
N12
N12
600 Series Deadbreak – Stick-Op,
Window-Op
N1. Window-Op Kit includes: insulated cap; Window-Op reducing tap plug; 600 Series elbow housing; cable adapter;
and 0370 style compression lug.
N2. Stick-Op Kit includes insulated cap; Stick-Op Loadbreak reducing tap plug; 600 A Elbow Housing; cable adapter;
and threaded 0360 style compression lug.
N3. 600AT assembly tool required for operation and/or installation of Stick-Op.
N4. For 900 A ratings, substitute 675 for 650 and 655; 676 for 656; K675 for K650 and K655; K676 for K656; 775
for 750 and 755; 776 for 756 and 2X for 0X in the Cat. No. The 900 A rating requires copper current-carrying
connector components and copper conductor cable.
N5. Add suffix symbol from page A29 to include cable shield grounding kit and/or cable jacket sealing kit.
N6. Aluminum lug for use on aluminum or copper conductors. DO NOT substitute threaded 03600X lug.
N7. Copper lug for use on COPPER CONDUCTOR ONLY. DO NOT substitute 03602X threaded lug.
N8. Threaded aluminum lug (Stick-Op only) for use on copper or aluminum conductors. DO NOT substitute
unthreaded 03700X lugs. DO NOT use with 675, 676, K675, K676, 775 or 776 Cat. Nos
N9. Threaded copper lug (Stick-Op only) for use on copper conductors only. DO NOT substitute unthreaded
03702X lugs.
N10.Required to disassemble Stick-Op loadbreak reducing tap plug from the threaded compression lug and
600 Series elbow after the shear-pin is broken during assembly.
N11.Stick-Op Operating Kit includes accessories that enable visible break direct testing, isolation, and grounding
functions to be performed. Kit includes: 3-insulated parking bushings; 3-grounding elbows; 3-600DB/200LB
bushing/elbow adapters; 1-assembly tool; 1-test rod; 1-carry case; 1-lubricant; 1-instructions.
N12.Window-Op Operating Kit includes accessories that enable visible grounding and direct testing functions to be
performed. Kit includes: 3-grounding elbows; 1-test rod; 1-carry case;1-lubricant; 1-instructions.
N13.600 Series Elbows and Straight Receptacles with IEEE Std. 386 capacitive test points are available by
substituting 656 for 655; K656 for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and 776 for
775 in the Cat. Nos.
N14.Rated for both 25 kV and 35 kV applications.
N15.600ATM assembly tool required for Window-Op assembly. 50 – 60 ft./lb. torque wrench required but
not included.
N16.Replacement Elbow includes: insulated cap; reducing tap plug; 600 series elbow housing; I-Adapter;
straight receptacle, resulting in a net gain of 20 in. length vs. a standard elbow kit. Compression lugs
and cable adapters are ordered separately.
Refer to the Wand Xtables on pages A39 to A41 for sizing to cable insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page A30.
Elastimold®Cable Accessories
A20
w w w . t n b . c a
600 Series Separable Cable Joints are available in 2, 3 and 4-way
versions and include a capacitive test point as standard. Units are
interchangeable, featuring bolted connections. Designs are compact
and ideally suited for small vaults and manholes.
DE-ENERGIZED joints can be quickly and easily connected and
disconnected using standard hand tools and equipment in accordance
with accepted operating practices. Bus bars can be changed to add or
remove cables from the joint.
Optional accessories include insulating and grounding caps and plugs
which allow visible external separation, by-pass, isolation,
dead-ending, grounding and testing.
See page A3–A4 for complete
information.
Current Ratings
(Prefixes: 650, K650, K655,
K656 and 03700)
600 A Continuous
25 kA sym., 10 cycles
Voltage Ratings
15/25 kV Class (5 kV thru 28 kV)
16.2 kV Phase-to-Ground
28 kV Phase-to-Phase
140 kV BIL
45 kV AC Withstand
84 kV DC Withstand
21.5 kV Corona Extinction
Note: Elastimold has increased the IEEE Standard
Prod uction and Design Test levels for 25 kV Class
products to include 27 kV and 28 kV systems.
SEPARABLE CABLE JOINTS – 600 SERIES DEADBREAK
600 Series Deadbreak – Cable Joints
4-WAY INSULATED BUS BAR
W/TEST POINT
INSULATED CAP WITH BAIL
B
SEPARABLE H-JOINT
(4-WAY)
SEPARABLE WYE-JOINT
(3-WAY)
SEPARABLE STRAIGHT-JOINT
(2-WAY)
Note: The separable cable joints shown here
use a special “Y” interace that may not be
interchangeable with other 600 Series
interfaces.
Dimension (in.)
A 4-1/4
B 37-1/8
C 8-1/8
D 3-7/8
OPERATING ACCESSORIES
GROUNDING CAP
GROUNDING PLUG
INSULATED PLUG
W/TEST POINT AND CAP
3-WAY INSULATED BUS BAR
W/TEST POINT
2-WAY INSULATED BUS BAR
W/TEST POINT
STRAIGHT RECEPTACLE HOUSING
RETAINING
RING
BOLT AND
WASHERS
CABLE ADAPTER
COMPRESSION LUG
Ratings Overview
A
C
D
Elastimold®Cable Accessories
A21
w w w . t n b . c a
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
Separable
Straight Joint Pkg.
(2-way)
w/ Test Point
15/25 kV K656I-W0X
Use Tables W7 and X6 N1, 8
Basic Housing Pkg.
Straight Joint
w/ Test Point
15/25 kV K656I-HP N2 N2
Separable
Wye Joint Pkg.
(3-Way)
w/ Test Point
15/25 kV K656CY-W0X
Use Tables W7 and X6 N1, 8
Basic Housing Pkg.
Wye Joint
w/ Test point
15/25 kV K656CY-HP N2
Separable
“H” Joint Pkg.
(4-Way)
w/ Test Point
15/25 kV K656CH-W0X
Use Tables W7 and X6 N1, 8
Basic Housing Pkg.
“H” Joint
w/ Test Point
15/25 kV K656CH-HP N2
2-Way
Insulated Bus Bar
w/Test Point
15/25 kV K656I-BUS N3
3-Way
Insulated Bus Bar
w/Test Point 15/25 kV K656CY-BUS N3
4-Way
Insulated Bus Bar
w/Test Point
15/25 kV K656CH-BUS N3
Straight
Receptacle 15/25 kV K655YSR-W0X
Use Tables W7 and X6 N4, 8
Direct Test Straight
Receptacle Elbow 15/25 kV K655YDSR-W0X
Use Tables W7 and X6 N4, 8, 11
Direct Test Straight
Receptacle Elbow
w/ Test Point
15/25 kV
K656YDSR-W0X
Use Tables W7 and X6 N4, 8, 11
Straight
Receptacle
Housing
Only
15/25 kV K655YBSR N5, 10
Insulated Ca
w/ Bail 15/25 kV K655YDR
Bail
Only 15/25 kV 650BA
Cable Adapter 15/25 kV 655CA-W
Use Table W7
Adapter
Retaining Ring 15/25 kV 650ARR -X
Use Table X6
Compression Lug 15/25 kV
15/25 kV
03700X N7
03702X N9
Use Table X6
N7
N9
600 Series Deadbreak – Cable Joints
N1. Complete Joint Packages consisting of: insulated bus bar; straight receptacle housings, retaining rings,
cable size adapters, lugs, bolts and washers.
N2. Housing Packages consisting of the following non-size sensitive components of the joint: insulated bus bar,
straight receptacle housings, bolts and washers.
N3. Insulated bus bar only.
N4. Straight Receptacle consisting of: straight receptacle housing, retaining ring, cable adapter, lug,
bolt and washers.
N5. Straight receptacle housing consisting of: straight receptacle housing, bolt and washers.
N6. Recommended for ease of assembly/disassembly of receptacles to Bus. 600 YADT is lever drive and
600RRT is screw drive.
N7. Aluminum lug for use on aluminum or copper conductors. DO NOT substitute threaded 03600X lug.
N8. Add suffix symbol from page A29 to include cable shield grounding kit and/or cable jacket sealing kit.
N9. Copper lug for use with COPPER CONDUCTOR ONLY. DO NOT substitute threaded 03602X lug.
N10.Available without the bolt and washers by adding “N” to the Cat. No.
N11.Direct Test Connectors, along with a 200TC-X series meter adapter, a properly rated voltage meter and Hot-line
Stick; provides a means for direct conductor voltage testing. See page A13 for meter adapters.
Refer to the Wand Xtables on pages A39 to A41 for sizing to cable insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page A30.
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
600 Series
Straight Receptacle
Size Sensitive
(Cable Adapter,
Retaining Ring
and Lug)
15/25 kV 655CK-W0X-ARR
Use Tables W7 and X6 N8
Insulating Plug w/
Test Point and Cap 15/25 kV K650YBIP
Grounding Plug
(4/0 AWG x 6’
Ground Lead)
15/25 kV 650YGP
Grounding Cap
(4/0 AWG x 6’
Ground Lead)
15/25 kV 650GYDR
Stainless Steel
Bolt and Washers 15/25 kV 650BAW
Assembly
Disassembly
Tool
ALL 600YADT-1 N6 N6
Assembly
Disassembly
Tool
ALL 600RR T N6 N6
Elastimold®Cable Accessories
A22
w w w . t n b . c a
Elastimold®multi-point junctions are available in 2, 3, 4, 5 or 6 point
configurations with 15, 25 or 35 kV ratings. Units feature modular
design flexibility, allowing selection of any combination of 200 A
deepwell or 600 A bushing interfaces located on standard 4 in. or
optional 6 1/2 in. centers. The 6 1/2 in. center spacing is especially
well suited for Distributed Switchgear applications including fused
elbow, MVI fault interrupter, MVS switch, etc.
Designs incorporate lightweight, damage resistant, EPDM molded
rubber construction and corrosion resistant 304 stainless steel
mounting brackets. Junctions are maintenance-free, fully shielded,
deadfront and submersible. Units are ideally suited for subsurface,
padmount, indoor and outdoor vault applications.
Elastimold multi-point junctions provide a convenient method for
connecting, looping and tapping of 200 and 600 A elbows and other
accessories at a common location where utilization of space, cable
training, flexibility and operability are important.
See page A3–A4 for complete
information.
Current Ratings
600 A Continuous
25 kA sym., 10 cycles
or with 200 A Bushing Well versions
200 A Continuous
10 kA sym., 10 cycles
Voltage Ratings
15 kV Class
8.3 kV Phase-to-Ground
95 kV BIL
34 kV AC Withstand
53 kV DC Withstand
11 kV Corona Extinction
25 kV Class
16.2 kV Phase-to-Ground
140 kV BIL
45 kV AC Withstand
84 kV DC Withstand
21.5 kV Corona Extinction
35 kV Class
21.1 kV Phase-to-Ground
150 kV BIL
50 kV AC Withstand
103 kV DC Withstand
26 kV Corona Extinction
DIMENSIONAL INFORMATION
Molded Multi-Point Junctions
A
J6-662266-25-SV
J6-622226-25
FIGURE 1: MULTI–POINT JUNCTIONS WITH 4 IN. INTERFACE SPACINGS. FIGURE 2: MULTI–POINT JUNCTIONS WITH 6-1/2 IN.
INTERFACE SPACINGS.
B
9/16 IN. X 1 IN. MOUNTING HOLES
5-1/2 IN. 6-3/4 IN.
4 IN.
TYP
5-1/4 IN.
GROUND LUG
NAME PLATE
C
A
B
C6-1/2 IN.
TYP
GROUND LUG
NAME PLATE
1-1/2 IN.
9/16 IN. X 1 IN. MOUNTING HOLES
5-1/2 IN.6-3/4 IN.
5-1/4 IN.
Type of
Junction
Figure 1 Figure 2
A B C
Number of
mounting
holes
A B C
Number of
mounting
holes
J2 15 7-1/2 6 6 19-1/2 10 8-1/4 6
J3 19 11-1/2 8 6 26 10 11-1/2 6
J4 24 15-1/2 10 6 32-1/2 23 9-1/4 8
J5 27 19-1/2 12 6 39 10 12 8
J6 31 23-1/2 9-3/8 8 45-1/2 36 8-1/4 10
Optional
Tilt Mounting Adapter.
15º TO 60º
ADJUSTABLE
ANGLE
Ratings Overview
Elastimold®Cable Accessories
A23
w w w . t n b . c a
Installation
(not to scale) Description Voltage
Class
Elastimold Cat. No.
Notes
4 in. Spacing 6-1/2 in. Spacing
2- point Junction
15 kV
25 kV
35 kV
J2 - __ __ - 15
J2 - __ __ - 25
J2 - __ __ - 35
J2 - __ __ - 15-SV
J2 - __ __ - 25-SV
J2 - __ __ - 35-SV
N1, 2
3- point Junction
15 kV
25 kV
35 kV
J3 - __ __ __ - 15
J3 - __ __ __ - 25
J3 - __ __ __ - 35
J3 - __ __ __ - 15-SV
J3 - __ __ __ - 25-SV
J3 - __ __ __ - 35-SV
N1, 2
4- point Junction
15 kV
25 kV
35 kV
J4 - __ __ __ __ - 15
J4 - __ __ __ __ - 25
J4 - __ __ __ __ - 35
J4 - __ __ __ __ - 15-SV
J4 - __ __ __ __ - 25-SV
J4 - __ __ __ __ - 35-SV
N1, 2
5- point Junction
15 kV
25 kV
35 kV
J5 - __ __ __ __ __ - 15
J5 - __ __ __ __ __ - 25
J5 - __ __ __ __ __ - 35
J5 - __ __ __ __ __ - 15-SV
J5 - __ __ __ __ __ - 25-SV
J5 - __ __ __ __ __ - 35-SV
N1, 2
6- point Junction
15 kV
25 kV
35 kV
J6 - __ __ __ __ __ __ - 15
J6 - __ __ __ __ __ __ - 25
J6 - __ __ __ __ __ __ - 35
J6 - __ __ __ __ __ __ - 15-SV
J6 - __ __ __ __ __ __ - 25-SV
J6 - __ __ __ __ __ __ - 35-SV
N1, 2
Base Catalogue Numbers
(J2-26-15 shown)
(J4-6226-15 shown)
(J3-626-35 shown)
(J5-62226-15 shown)
(J6-622226-15 shown)
ORDERING INFORMATION
To specify and order Elastimold Multi-Point Junctions:
1. Use Table 1 to construct a catalogue number describing the required junction.
Ordering Example A
To order a 4-point, 15 kV junction with 4 in. spacings and 600 Series interfaces
on the outside ways and 200 A wells on the inside ways specify: Catalogue Number J4-6226-15
Ordering Example B
To order a 6-point, 25 kV junction with 6-1/2 in. spacings and 600 Series interfaces on the ways
1, 3, 4, 6 and 200 A wells on the ways 2 and 5 specifiy: Catalogue Number J6-626626-25-SV
N1. The 6-1/2 in.wide spacing is necessary if the junction is to be used to connect with a single-phase MVS Molded Vacuum Switch or MVI Molded Vacuum Interrupter.
N2. Also available with a shorter bracket by reducing the number of parking stands, see R, L, N above.
Table 1. Catalogue Number Construction
Number of Points
2 2 Points
3 3 Points
4 4 Points
5 5 Points
6 6 Points
Multi-Point
Junction
J
Interface Identification *
and Positioning
2 200 A Deepwell Interface
6 600 A Bushing Interface
B Blank Position
*When there is a 200 A Interface on one side of the junction and a 600 Series
Interface on the other side, always start with the 200 A side.
Voltage Class
15 15 kV
25 25 kV
35 35 kV
Interface Spacing
Blank Standard spacing –
4 in. centers
SV Optional 6-1/2 in.centers
Options
Blank No tilt mounting bracket
TMA
Tilt Mounting Adapter. Bolts to the
bottom of the standard mounting
bracket to provide 15, 30, 45 or 60
degree adjustable angle mounting.
(Two Tilt Mounting Adapters are
required for each installation.)
L Left parking stand only
R Right parking stand only
N No parking stand
----
Molded Multi-Point Junctions
Elastimold®multi-point junctions feature modular design flexibility that permits the specifier to determine
the positions of the bushing interfaces and bushing well positions.
Elastimold®Cable Accessories
A24
w w w . t n b . c a
PCJPower Cable Joints utilize permanently crimped connectors.
PCJ Housings are fully in sulated, shielded and sealed for direct buried,
vault, submersible and other severe service applications. Units have
been designed and tested per IEEE Standard 404 to assure system
matched performance and ratings equal to the cable to which the
splice will be installed.
PCJ Power Cable Joints are available in 2 styles:
Style 1 uses a single piece housing that is sized to accommodate a
specific range of cable. Style 1 units are ideally suited for straight
splicing of the same or similar cable.
Style 2 designs incorporate a universal housing with separate
cable adapters to allow transition splices of different types and sizes
of cable.
PCJPower Cable Joints
ELECTRICAL RATINGS SUMMARY
The following ratings summary is based on IEEE Std. 404 and applies to all
Elastimold PCJ Power Cable Joints.
Voltage
A. 15 kV Class (8.7 kV Phase-to-Ground)
B. 25 kV Class (14.4 kV Phase-to-Ground)
C. 35 kV Class (20.2 kV Phase-to-Ground)
Impulse Withstand: A=110 kV, B=150 kV, C=200 kV BIL,1.2 x 50
microsecond wave
Corona Extinction Voltage: A=13 kV, B=22 kV, C=30 kV minimum,
3pC sensitivity
DC Withstand: During installation: A=56 kV, B=80 kV, C=100 kV
DC Withstand:
After installation and in service for the first 5 years:
A=18 kV, B=25 kV, C=31 kV for XLPE Insulated Cables
and A=45 kV, B=64 kV, C=80 kV for EPR Insulated Cables
(Reference AEIC CS6 and CS8, Section L.2.)
Current
Continuous rating equal to the rating of the cable
Short-Time rating equal to the rating of the cable up to 35 kA
Shield Design
Meets IEEE standard 592 for Exposed Semiconducting Shields
on Premolded High Voltage Cable Joints and Separable
Insulated Connectors
Production tests include 100% tests of the premolded joints to assure:
Corona Extinction Voltage: A=13 kV, B=22 kV, C=30 kV minimum,
3pC sensitivity
AC Withstand: A=35 kV, B=52 kV, C=69 kV, 60 Hz, 1 minute
Design tests on production joints demonstrate
compliance with IEEE 404 including:
Corona Extinction Voltage: A=13.0 kV, B=22.0 kV, C=30.0 kV
minimum, 3pC sensitivity
AC Withstand: A=35 kV, B=52 kV, C=69 kV, 60 Hz 1 minute.
DC Withstand: A=70 kV, B=100 kV, C=125 kV negative polarity,
15 minutes
Impulse Withstand (BIL): A=110 kV, B=150 kV, C=200 kV,
10 positive and 10 negative, 1.2 x 50 microsecond wave, at
conductor temperatures of 20º and 130ºC, nominal
Short-Time Current: magnitude equal to cable up to 35 kA
Cyclic Aging: 30 days at: A=26.1 kV, B=43.2 kV, C=60.6 kV AC
continuous, load current for 8 hours per day, providing 130º conductor
temperature. Joints then subjected to: A=31 kV, B=50 kV, C=71 kV
for 5 hours followed by: A=39 kV, B=65 kV, C=91 kV for 5 min.
Load Cycle: Connectors meet require ments of ANSI C119.4,
Class A and Class 3 ratings
Elastimold®Cable Accessories
A25
w w w . t n b . c a
1 5 P C J 1 W 1 X
Style 1
Cat. No.
A B
(in.) (in.)
15PCJ1FX 10-1/4 1-3/4
15PCJ1GX 10-1/4 1-3/4
25PCJ1GX 14-3/8 2-7/16
15/25/35PCJ1HX 14-3/8 2-7/16
15/25/35PCJ1JX 14-3/8 2-7/16
15/25/35PCJ1KX 14-3/8 2-25/32
15/25/35PCJ1LX 14-3/8 2-25/32
15/25PCJ1LMX 14-3/8 2-25/32
15/25/35PCJ1MX 14-3/8 2-25/32
15/25/35PCJ1NX 15-3/4 3-3/16
15/25/35PCJ1PX 15-3/4 3-3/16
15/25/35PCJ1QX 15-3/4 3-3/16
Voltage
Class
Power
Cable
Joint
Insulation
Diameter
Conductor
Size Code
Style
Conductor
1 - Style 1
2 - Style 2
1 - Aluminum
2 - Copper
W SIZING INFORMATION AND SELECTION
Use Table W8 for 15PCJ
Use Table W9 for 25PCJ
Use Table W10 for 35PCJ
X SIZING INFORMATION AND SELECTION
Use Table X7 for 15PCJ, 25PCJ and 35PCJ
DIMENSIONAL DATA
Style 2
Cat. No.
A B
(in.) (in.)
15PCJ2FX 16-3/8 2-25/32
15/25PCJ2GX 16-3/8 2-25/32
15/25/35PCJ2HX 16-3/8 2-25/32
15/25/35PCJ2JX 16-3/8 2-25/32
15/25/35PCJ2KX 21 3-3/4
15/25/35PCJ2LX 21 3-3/4
15/25/35PCJ2MX 21 3-3/4
15/25/35PCJ2NX 21 3-3/4
15/25/35PCJ2PX 21 3-3/4
15/25/35PCJ2QX 21 3-3/4
DIMENSION B
OUTSIDE DIA.
DIMENSION A
OVERALL LENGTH
Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
Power Cable
Joint
Style 1
15 kV
15 kV
25 kV
25 kV
35 kV
35 kV
15PCJ1W1X
15PCJ1W2X
25PCJ1W1X
25PCJ1W2X
35PCJ1W1X
35PCJ1W2X
N1
N2
N1
N2
N1
N2
Power Cable
Joint
Style 2
15 kV
15 kV
25 kV
25 kV
35 kV
35 kV
15PCJ2W1X
15PCJ2W2X
25PCJ2W1X
25PCJ2W2X
35PCJ2W1X
35PCJ2W2X
N1
N2
N1
N2
N1
N2
N1. Kit includes aluminum compression connector suitable for splicing aluminum conductor to aluminum conductor or aluminum
conductor to copper conductor. An all-copper connector is required for copper-to-copper connections.
N2. Kit includes copper compression connector suitable for splicing copper conductors to copper conductor only.
DO NOT use copper connectors on aluminum conductors.
Refer to the Wand Xtables on pages A39 to A41 for sizing to cable insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page A30.
ORDERING INFORMATION
PCJ Style 2
with universal housing and separate cable adapters
that can be varied with the cable application.
PCJPower Cable Joints
PCJ Style 1
with single-piece housing
Elastimold®Cable Accessories
A26
w w w . t n b . c a
The following ratings summary is based
on IEEE Std. 48 and applies to all the
terminations on pages A26 thru A29.
Elastimold terminations are designed for use
on three-phase systems, either 3-wire or
4-wire and the single-phase laterals of these
systems.
Voltage Ratings
15 kV Class
9.5 kV Phase-to-Ground
110 kV BIL 1.2 x 50 microsecond wave
AC Withstand:
50 kV 1 min. – dry
35 kV 6 hr. – dry
45 kV 10 sec. – wet
13 kV Corona Extinction
25 kV Class
16 kV Phase-to-Ground
150 kV BIL 1.2 x 50 microsecond wave
AC Withstand:
65 kV 1 min. – dry
55 kV 6 hr. – dry
60 kV 10 sec. – wet
21.5 kV Corona Extinction
35 kV Class
22 kV Phase-to-Ground
200 kV BIL 1.2 x 50 microsecond wave
AC Withstand:
90 kV 1 min. – dry
75 kV 6 hr. – dry
80 kV 10 sec. – wet
30 kV Corona Extinction
Electrical Ratings
Summary
Cable Terminations
Elastimold®cable terminations are available in single piece or modular
designs. Terminators allow connection and transition from shielded,
underground cable to bare overhead conductors and live-front
equipment. Units are designed and rated per IEEE Standard 48 for
riser pole, padmount, indoor and outdoor applications. PCT1, PCT2,
16THG and 35MTG terminators provide sufficient creep, strike and
weather sealing for class 1 outdoor service. PCT1 and PCT2 also
include an integral cable jacket seal.
The 35MTGI terminators and 35MSC stress cones are rated for class
2 and class 3 indoor service respectively. Optional mounting brackets,
aerial lugs and equipment connectors are available as required.
TERMINATIONS
SINGLE PIECE TERMINATORS STRESS CONE MODULAR TERMINATORS
BRACKETS
PCT-1 PCT-2 16THG 16THGS 35MSC 35MSCI 35MTGI 35MTG
PB-1 16TB2 35MTB 1535AFB
Elastimold®Cable Accessories
A27
w w w . t n b . c a
Cable Terminations
Refer to the Wand Xtables on pages A39 to A41 for sizing to cable insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page A30.
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
Single-Piece
Terminator
(Class 1)
15 kV
25 kV
PCT1-1X-4
Use Table X9
PCT2-1X-4
Use Table X9
N12, 14,
15, 22
N12, 14,
N15, 23
Housing
only
15 kV
25 kV
PCT1-4
PCT2-4
N13,22
N13,23
Single-Piece
Terminator
(Class 1)
15/25 kV 16THG-W0X-4
Use Tables W12 and X8
N2, 14
15
Housing
only 15/25 kV 16THGH-W
Use Table W12
Single-Piece
Terminator
for solid
conductor only
(Class 1)
15/25 kV 16THGS-WX
Use Tables W12 and X4 N3
Stress Cone
(Class 3) ALL 35MSC-W
Use Table W11 N17
Stress Cone
w/Grd. Strap ALL 35MSCI-W
Use Table W11 N17
Modules
only ALL 35MG-W
Use Table W13 N11, 16
Modular
Terminator
(Class 1)
15 kV
25 kV
35 kV
35MTG-WX-4-CA
Use Tables W13 and X3
35MTG-WX-8-CA
Use Tables W13 and X3
35MTG-WX-10-CA
Use Tables W13 and X3
N2, 11
N2, 5, 11
N2, 6, 11
Modular
Terminator
(Class 2)
w/o Rain
Cap
15 kV
25 kV
35 kV
35MTGI-W-4
Use Table W13
35MTGI-W-6
Use Table W13
35MTGI-W-8
Use Table W13
N11
N11
N7, 11
Rod Contact
for PCT 15/25 kV 00700X
Use Table X9
N1, 14,
15
Rod Contact
for 16THG 15/25 kV 16TCA-X
Use Table X8 N2, 8
Solid Conductor
Package
for 16THGS
15/25 kV 16CAS-X
Use Table X4 N3, 9
3/4 in.-16
Threaded
Rod for MTG
ALL 35MTGA-WX-1
Use Tables W13 and X3
N2, 10, 11
18, 25
1 in.-14 Threaded
Rod for MTG ALL 35MTGA-WX-2
Use Tables W13 and X3A
N2, 10, 11
19, 25
Two-Hole Spade
for MTG ALL 35MTGA-WX-3
Use Tables W13 and X3
N4, 10, 11
20, 25
Two-Hole Spade
for PCT ALL 01000X
Use Table X9 N1
One-Hole Spade
for PCT ALL 01100X
Use Table X9 N1
Universal Rod
for MTG ALL 35MTGA-WX-4
Use Tables W13 and X3
N2, 10, 11
21, 25
Aerial Lugs
for MTG
Threaded Rod
(Two-hole spade
or bare wire)
ALL 35AL-A N10, 24
N1. Use with PCT1 or PCT2 Terminators.
N2. Includes contact rod, ground strap and rain cap.
N3. Includes crimp ring, ground strap and rain cap.
N4. Includes spade contact, ground strap and rain cap.
N5. For KA thru PB sizes use 35MTG-WX-6-CA.
N6. For KA thru PB sizes use 35MTG-WX-8-CA.
N7. For KA thru PB sizes use 35MTGI-W-6.
N8. Use with 16THG Terminators.
N9. Use with 16THGS Terminators.
N10.Use with 35MTG Terminators.
N11.Refer to page A26 for detailed ordering instructions.
N12.Includes rod contact as standard. Specify suffix “-3” in place of “-4” for two-hole spade lug. Specify suffix “-5”
in place of “-4” for one-hole spade lug.
N13.Specify suffix “-3” or “-5” in place of “-4” for two-hole spade lug housing or one- hole spade style housing.
N14.Use 1X for an aluminum rod contact for aluminum conductors only.
N15.Substitute 0X for 1X for a universal aluminum rod contact for aluminum or copper conductors.
N16.Available in sizes from GA thru PB and are supplied qty. 2 per package.
N17.Available in sizes EB thru PB.
N18.For conductors from 1/0 thru 350 kcmil.
N19.For conductors from 400 kcmil thru 1000 kcmil.
N20.For conductors from #2 to 1000 kcmil.
N21.For conductors from #6 thru 4/0.
N22.Use for insulation dia. range from .640 in. thru 1.070 in.
N23.Use for insulation dia. range from .830 in. thru 1.180 in.
N24.Select symbol for “A from aerial lug ordering information on page A28.
N25.W13 Table provides sizing for rain cap. X10 Table provides sizing for connectors.
Elastimold®Cable Accessories
A28
w w w . t n b . c a
Cable Terminations
35MTG - W X - N - C A
Use Table W13, below
ORDERING INSTRUCTIONS FOR MODULAR TERMINATORS
I - Indoor
Blank = Outdoor
Use Table X3 or Table X3A
Recommended
Number of Modules
NOTE: Applicable table and available sizes depend upon connector style.
Reference Connector Style Selection Chart and notes A through D.
Connector Style Selection Chart
Description Available for
Conductor
Sizes
Symbol Notes
3/4 in.-16
Threaded
Rod
1/0 thru
350 kcmil
-1 A
1 in.-14
Threaded
Rod
400 thru
1000 kcmil
-2 B
2-Hole
Spade
#2 thru
1000 kcmil
-3 C
Universal
Rod
#6 thru 4/0 -4 D
Aerial Lugs for
Threaded Rod
Connectors Only
Type Connector Symbol
Bare Wire 3/4 in.-16
Rod
-11
2-Hole Spade 3/4 in.-16
Rod
-12
Bare Wire 1 in-14
Rod
-21
2-Hole Spade 1 in-14
Rod
-22
NOTES:
A. Available for 1/0 through 350 conductor sizes only. Use Table X3 for size selection.
B. Available for 400 through 1000 conductor sizes only. Use Table X3A for size selection.
C. Available for #2 through 1000 conductor sizes only. Use Table X3 for size selection.
D. Available for #6 through 4/0 conductor sizes only. Use Table X3 for size selection.
Table W13
USE FOR
FOLLOWING
PRODUCTS
35MTG
35MTGI
Cable insulation
Diameter in (in.) Symbol
for W
Min. Max.
0.775 0.885 GA
0.825 0.935 GAB
0.875 0.985 GB
0.930 1.040 GH
0.980 1.115 HA
1.040 1.175 HAB
1.095 1.240 HB
1.160 1.305 HJ
1.220 1.375 JA
1.285 1.395 JAB
1.355 1.520 JB
1.485 1.595 KA
1.530 1.640 KAB
1.575 1.685 KB
1.665 1.785 PA
1.755 1.875 PB
Table X3A
USE FOR
FOLLOWING
PRODUCTS
35MTG
FOR USE
WITH STYLE-2
CONNECTORS
ONLY.
SEE NOTES B
FOR APPLICATION
INFORMATION
Conductor
SIZE AWG
or kcmil
Symbol for X
Strand./
Compr.
Compt./
Solid
400 400
450 450 400
500 500 450
550 550 500
600 600 500
650-700 650 550
750 750 600
800 750 650
1000 1000
Table X3
USE FOR
FOLLOWING
PRODUCTS
35MTG
FOR USE WITH
STYLE-1,-3, and -4
CONNECTORS
ONLY.
SEE NOTES A,
C, and D FOR
APPLICATION
INFORMATION
Conductor
SIZE AWG
or kcmil
Symbol for X
Strand./
Compr.
Compt./
Solid
#6 5
#5 4 5
#4 3 4
#3 2 3
#2 1 2
#1 0 1
1/0 10 0
2/0 20 10
3/0 30 20
4/0 40 30
250 250 40
300 300 250
350 350 300
400 400 350
450 450
500 500 400
550 550 450
600 600 500
650 650 550
700 750 600
750 750 650
800 800 750
900 900 800
1000 1000 900
GA-JB KA-PB
15 kV 4 4
25 kV 8 8
35 kV 10 10
Elastimold®Cable Accessories
A29
w w w . t n b . c a
Cable Terminations
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No. Notes
PCT
Positioning
Bracket
ALL PB-1 N1, 12
16THG Bracket ALL 16TB-2 N6
Bracket
for crossarm
16THG
ALL 16TB-3 N6
Bracket
for riser pole
mounting
16THG
ALL 16TB-4 N6
Bracket
for tri-mounting
16THG
ALL 16TB-5 N6
KELLUMS
GRIP
Bracket
ALL
ALL
ALL
ALL
35MTB1-A
35MTB1-B
35MTB1-C
35MTB1-D
N1, 2, 6, 7
N1, 3, 6, 7
N1, 4, 6, 7
N1, 5, 6, 7
KELLUMS
Bracket
for crossarm
mounting
ALL
ALL
ALL
ALL
35MTB3-A
35MTB3-B
35MTB3-C
35MTB3-D
N1, 2, 6, 7
N1, 3, 6, 7
N1, 4, 6, 7
N1, 5, 6, 7
Bracket
(for riser pole
mounting)
ALL
ALL
ALL
ALL
35MTB4-A
35MTB4-B
35MTB4-C
35MTB4-D
N1, 2, 6, 7
N1, 3, 6, 7
N1, 4, 6, 7
N1, 5, 6, 7
KELLUMS
Bracket
for tri-mounting
ALL
ALL
ALL
ALL
35MTB5-A
35MTB5-B
35MTB5-C
35MTB5-D
N1, 2, 6, 7
N1, 3, 6, 7
N1, 4, 6, 7
N1, 5, 6, 7
ALUMA FORM
Bracket ALL 1535AFB-1 N1, 6 ,7, 13
ALUMA FORM
Bracket
for Crossarm
mounting
ALL 1535AFB-3 N1, 6, 7, 13
ALUMA FORM
Bracket
for riser-pole
mounting
ALL 1535AFB-4 N1, 6, 7, 13
ALUMA FORM
Bracket
for tri-mounting
ALL 1535AFB-5 N1, 6, 7, 13
N1. Use with PCT-1 or PCT-2 Terminators.
N2. Fits overall cable O.D. from 1.195 in. to 1.625 in.
N3. Fits overall cable O.D. from 0.925 in. to 1.335 in.
N4. Fits overall cable O.D. from 0.890 in. to 1.185 in.
N5. Fits overall cable O.D. from 1.500 in. to 2.000 in.
N6. Use with 16THG and 16THGS Terminators.
N7. Use with MTG, MTG1 and MSC Terminators.
N8. For conductors from 1/0 thru 350 kcmil.
N9. For conductors from 400 kcmil thru 1000 kcmil.
N10.For conductors from #2 to 1000 kcmil.
N11.For conductors from #6 thru 4/0.
N12.Fits overall cable O.D. from 0.750 in. to 1.625 in.
N13.Fits overall cable O.D. from 0.750 in. to 2.000 in.
TERMINATIONS
Refer to the Wand Xtables on pages A39 to A41 for sizing to cable insulation diameter and conductor size.
For cable shield adapters and jacket seals, see page A30.
Elastimold®Cable Accessories
A30
w w w . t n b . c a
Shield Adapters, Sealing and Grounding
Elastimold cable terminations are available in single piece or modular designs.
Terminators allow connection and transition from shielded, underground cable to bare
overhead conductors and live-front equipment. Units are designed and rated per IEEE
Standard 48 for riser pole, padmount, indoor and outdoor applications. PCT1, PCT2,
16THG and 35MTG terminators provide sufficient creep, strike and weather sealing for
class 1 outdoor service. PCT1 and PCT2 also include an integral cable jacket seal.
The 35MTGI terminators and 35MSC stress cones are rated for class 2 and class 3 indoor
service respectively. Optional mounting brackets, aerial lugs and equipment connectors
are available as required.
CABLE ENTRANCE DETAIL
600/200
ECS
INSULATION
EPDM RUBBER
MOLDED SHIELD
CONDUCTIVE EPDM RUBBER
600/200
ECSG1-2 21MA 20MA 600/200
ECSG2-2
600/200
ECSG3 10 TL 10 TL
NONE
REQUIRED
CONDUCTOR
INSULATION
EXTRUDED SHIELD
CONCENTRIC
NEUTRAL WIRES
OUTER JACKET
CABLE
SHIELD
TYPES
JACKETED
CONCENTRIC
NEUTRAL
CABLE
CONCENTRIC
NEUTRAL
CABLE
DRAIN
WIRE
SHIELDED
CABLE
COPPER
TAPE
SHIELDED
CABLE
LEAD
JACKETED
CABLE
UNSHIELD
CABLE
CONDUCTOR
INSULATION
EXTRUDED SHIELD
CONCENTRIC
NEUTRAL WIRES
CONDUCTOR
INSULATION
EXTRUDED SHIELD
DRAIN WIRES
OUTER JACKET
CONDUCTOR
INSULATION
EXTRUDED SHIELD
COPPER SHIELD
OUTER JACKET
CONDUCTOR
INSULATION
EXTRUDED SHIELD
OUTER JACKET
CONDUCTOR
INSULATION
EXTRUDED
CONDUCTIVE
JACKET
DRAIN WIRES
20MA10TL 21MA ECS
CABLE SHIELD ADAPTERS
Cable
Insulation Dia.
10TL 20MA 21MA
(in.) (in.) (in.)
min. 0.495 0.530 0.530
max. 1.875 1.780 1.780
JACKET SEALS
Jacket
O.D.
200ECS 600ECS
(in.) (in.)
min. 0.80 1.28
max. 1.50 2.30
Elastimold®Cable Accessories
A31
w w w . t n b . c a
Shield Adapters, Sealing and Grounding
N1. To order the kits as separate items, use the Cat. Nos shown in the table.
Example: To order a cold shrinkable tube as a separate item, use the Cat. No. 200ECS.
To order the kits as components of other items, add the suffix to the end of the Cat. No.
Example: To order a cold shrinkable jacket seal as a component of an elbow kit, use
the Cat. No. 166LR-A5200-S.
N2. Only use this suffix with Cat. Nos that designate a “W” housing size. Sizing the main
component will also size the suffix adapter.
N3. Size range 0.80 in. to 1.50 in. jacket diameters. Maximum installed diameter is approx. 02 in.
N4. Size range 1.28 in. to 2.30 in. jacket diameters. Maximum installed diameter is approx. 2.75 in.
N5. Voltage rating equal to Elastimold product being used.
N6. Copper rod size is no. 6 for sizes FA thru HA and no. 2 for sizes HAB thru JB.
N7. Braid is equivalent to no. 6 copper rod for sizes FA thru HA and no. 2 copper rod for sizes HAB thru JB.
Illustration
(not to scale) Description ELASTIMOLD
Cat. No. Suffix Notes
Cold Shrinkable
Jacket Seal 200ECS -S N1, 3
Cold Shrinkable
Jacket Seal 600ECS -S N1, 4
Metallic Tape
Shield Adapter
20MA-W
Use Table W14
for sizing
-0MA N1, 2, 5, 6
Wire Shield
Adapter
21MA-W
Use Table W14
for sizing
-1MA N1, 2, 5, 6
Shield
Adapter
10TL-W
Use Table W15
for sizing
-TL N1, 2
Cold Shrinkable Seal
w/ Copper Rod and
Crimp Connector
200ECSG1-2 -SG1 N1 ,3 ,5, 6
Cold Shrinkable Seal
w/ Copper Rod and
Crimp Connector
600ECSG1-2 -SG1 N1, 4, 5, 6
Cold Shrinkable Seal
w/ Copper Rod and
Constant Force
Spring
200ECSG2-2 -SG2 N1, 3, 5, 6
Cold Shrinkable Seal
w/ Copper Rod and
Constant Force
Spring
600ECSG2-2 -SG2 N1, 4, 5, 6
Cold Shrinkable Seal
w/ Copper Braid and
Constant Force
Spring
200ECSG3 -SG3 N1, 3, 5, 7
Cold Shrinkable Seal
w/ Copper Braid and
Constant Force
Spring
600ECSG3 -SG3 N1, 4, 5, 7
Table W14
USE FOR
20MA
21MA
Insulation
Symbol
for W
(in.)
Min. Max.
0.530 0.680 E
0.640 0.820 F
0.760 0.950 G
0.850 1.050 H
0.980 1.180 J
1.090 1.310 K
1.180 1.465 L
1.370 1.630 M
1.515 1.780 N
Table W15
USE FOR
10TL
Insulation
Symbol
for W
(in.)
Min. Max.
0.495 0.585 EB
0.525 0.635 EF
0.575 0.585 FA
0.625 0.735 FAB
0.675 0.785 FB
0.725 0.835 FG
0.775 0.885 GA
0.825 0.935 GAB
0.875 0.985 GB
0.930 1.040 GH
0.980 1.115 HA
1.040 1.175 HAB
1.095 1.240 HB
1.160 1.305 HJ
1.220 1.375 JA
1.285 1.395 JAB
1.355 1.520 JB
1.485 1.595 KA
1.530 1.640 KAB
1.575 1.685 KB
1.755 1.875 PB
Elastimold®Cable Accessories
A32
w w w . t n b . c a
Equipment Bushings
A complete line of Elastimold® 200 A deep well and 600 Series
apparatus bushings are available for use on transformers, switchgear
and other equipment applications.
The bushings incorporate IEEE 386 standard interfaces (shown
on page A5) and are constructed of molded epoxy with stainless
steel flanges for mounting by welding or gasketed clamp.
K1601PCC Series bushings are provided with a molded epoxy flange
for gasketed clamp mounting only. Bushings are available for use on
AIR, OIL or SF6 insulated equipment. Units are rated for submersible,
padmount, indoor, outdoor and other applications. Options include
hold-down bail tabs and replaceable studs for 200 A deepwell
bushings.
N1. Replacement stud available separately. Specify 1601RS.
N2. Equipped with standard aluminum conductor rod.
N3. Equipped with copper conductor rod.
N4. Includes 5/8-11 threaded stud at elbow end.
N5. Includes 5/8-11 threaded hole at elbow end.
N6. Provides increased creep and strike.
N7. Includes 1601PPC1 shipping cap.
N8. Includes 1601APC1 shipping cap.
N9. Includes 2701-41 shipping cap.
N10.Includes 180PPC shipping cap.
N11.Includes 650PPC shipping cap.
N12.Includes 750PPC1 shipping cap.
N13.Parking stands for 200 A deadbreak applications are available as separate items. Specify 151PS.
N14.Parking stands for 200 A loadbreak and 600 A deadbreak applications are available as
separate items. Specify 160PS.
N15.Aluminum stud available separately. Specify 650SA.
N16.Aluminum stud available separately. Specify 750SA.
Illustration
(not to scale) Description Voltage
Class
ELASTIMOLD
Cat. No.
Bushing
Shank Length Notes
Short Shank Well with bail tabs
and non-replaceable well stud
15/25 kV
35 kV
K1601PC-S1
L1601PC-S1 2-3/4 in. N3, 7, 14
Short Shank Well with bail tabs
and with replaceable well stud
15/25 kV
35 kV
K1601PC-S1-R
L1601PC-S1-R 2-3/4 in. N1, 3, 7, 14
Short Shank Well without bail tabs
and non-replaceable well stud
15/25 kV
35 kV
K1601PC-S2
L1601PC-S2 2-3/4 in. N3, 7, 14
Short Shank Well without bail tabs
and with replaceable well stud
15/25 kV
35 kV
K1601PC-S2-R
L1601PC-S2-R 2-3/4 in. N1, 3, 7, 14
Long Shank Well with bail tabs
and non-replaceable well stud
15/25 kV
35 kV
K1601PC-T1
L1601PC-T1 9-1/4 in. N3, 7, 14
Long Shank Well with bail tabs
and with replaceable well stud
15/25 kV
35 kV
K1601PC-T1-R
L1601PC-T1-R 9-1/4 in. N1, 3, 7, 14
Long Shank Well without bail tabs
and non-replaceable well stud
15/25 kV
35 kV
K1601PC-T2
L1601PC-T2 9-1/4 in. N3, 7, 14
Long Shank Well without bail tabs
and with replaceable well stud
15/25 kV
35 kV
K1601PC-T2-R
L1601PC-T2-R 9-1/4 in. N1, 3, 7, 14
Epoxy Flange Well with replaceable well stud 15/25 kV K1601PCC-R N1,3, 7, 14
Well w/Insert (K1601PCC-R and 1601A4)
Well w/Insert (K1601PCC-R and 2701A4)
15 kV
25 kV
1601CABA4R
2701CABA4R 2-3/4 in. N1, 3, 8, 14
N1, 3, 9, 14
200 A Deadbreak Bushing
200 A Deadbreak Bushing
200 A Deadbreak Bushing
15/25 kV
15/25 kV
15/25 kV
K180S4
K180T4
K180C4
2-9/16 in.
7-11/32 in.
9-1/4 in.
N3 ,10 ,13
600 A Short Shank Bushing w.o./stud
600 A Short Shank Bushing w.o./stud
600 A Cu Short Shank Bushing w.o./stud
15/25 kV
35 kV
15/25 kV
K650S1
750S1
K675S1
2-15/16 in.
N2, 5, 11, 14, 15
N2, 5, 12, 14, 16
N3, 5, 11, 14, 15
600 A Long Shank Bushing w.o./stud
600 A Cu Long Shank Bushing w.o./stud
600 A Long Shank Bushing w.o./stud
600 A 12 in. Long Shank Bushing w.o./stud
15/25 kV
15/25 kV
35 kV
35 kV
K650T1
K675T1
750T1
750L12
8-9/16 in.
8-9/16 in.
8-9/16 in.
12 in.
N2, 5, 11, 14, 15
N3, 5, 11, 14, 15
N2, 5, 12, 14, 16
N2, 5, 12, 14, 16
600 A In-Air Long Shank Bushing w.o./stu
600 A Cu In-Air Long Shank Bush. w/stud
Boot and Collars for K600T1 to use in air
15/25 kV
15/25 kV
15/25 kV
K650TBC
K675TBC
600BC
8-9/16 in.
N2, 4, 11, 6, 14
N3, 5, 11, 6, 14
N6
Elastimold®Cable Accessories
A33
w w w . t n b . c a
How to Specify Size-Sensitive Products
Ordering Examples
AEIC
To complete the information required to order a K655LR-W0X elbow
for use on standard AEIC 1000 kcmil compressed stranding
aluminum 25 kV cable with .260 inch thick insulation wall:
A. Determine that the insulation diameter (for AEIC cable in
the table on pages A35-A37) is 1.645 – 1.770 in.
B. For this elbow, the Cat. No. selection chart on page A13
indicates to use table W7 for elbow sizing and table X6 for
connector sizing.
C. From table W7 the symbol for W is N.
D.From table X6 the symbol for X is 410.
E. The completed Cat. No. therefore is K655LR-N0410.
ICEA
To complete the information required to order a K655LR-W0X elbow
for use on standard ICEA 1000 kcmil compressed stranding aluminum
25 kV cable with .260 inch thick insulation wall:
A. Determine that the insulation diameter (for ICEA cable in
the table on pages A35-A37) is 1.645 – 1.740 in.
B. For this elbow, the Cat. No. selection chart on page A13
indicates to use table W7 for elbow sizing and table X6 for
connector sizing.
C. From table W7 the symbol for W is N.
D.From table X6 the symbol for X is 410.
E. The completed Cat. No. therefore is K655LR-N0410.
PN
Elastimold Elbows, cable joints and terminations are designed for application on XLP, EPR and other solid dielectric insulated power cables.
These components are constructed of molded elastomer and rely on an interference fit with the cable insulation diameter in order to maintain
proper dielectric strength, creep path integrity and a water seal. Elastimold components are available in a wide range of sizes in order to
accommodate a variety of cable insulation diameters.
Selection of size-sensitive components requires determining the cable insulation diameter.
This can be done in several ways:
A. Refer to the cable manufacturer’s spec sheet for dimensions.
B. Measure the cable.
C. If the cable conforms to AEIC or ICEA standards and is:
1. 15 kV, 175 mil wall thickness, use the table on page A35.
2. 15 kV, 220 mil wall thickness, use the table on page A36.
3. 25 kV, 260 mil wall thickness, use the table on page A36.
4. 35 kV, 345 mil wall thickness, use the table on page A37.
After the cable insulation diameter minimum and maximum has been determined:
1. Locate the W table indicated in the Cat. No. selection chart.
2. Complete the ordering information by selecting and inserting the symbol (given in the W table) into the Cat. No.
——-WX-——
“W”
CABLE
INSULATION
DIAMETER
Determines Size of Molded Rubber Part
“W”
INSULATION
DIAMETER
INSULATION DIAMETER SELECTION GUIDE
Elastimold®Cable Accessories
A34
w w w . t n b . c a
How to Specify Size-Sensitive Products
Elastimold®elbows, cable joints and terminations are furnished with crimp style
cable connectors. As standard, these connectors are constructed with a tin-plated
aluminum barrel filled with an oxide inhibitor. Most aluminum barrel connectors are
universal and are designed for use on either aluminum or copper conductor cable.
When specified, all copper crimp style connectors can be furnished. These
connectors are only for use on copper conductor cable and are not for use with
aluminum conductor cables. Bi-metallic connectors are constructed with a copper
top and an aluminum barrel. Bi-metal connectors can be used on either aluminum or
copper conductor cable and are furnished as standard with 200 A Loadbreak Elbows,
200 A Deadbreak Elbows, and PCT, 16 THG or MTG terminators with rod connectors.
Aluminum connectors used in PCJ Cable Joints are rated as follows:
Aluminum conductor to aluminum conductor, cable rated
Aluminum conductor to copper conductor, cable rated equal to the
aluminum cable
Copper connectors used in PCJ Cable Joints are rated as follows:
Copper conductor to copper conductor, cable rated
Selection and ordering the proper crimp connector requires determining
information relative to the cable conductor as follows:
A. Conductor size in AWG or kcmil
B. Conductor type (stranded, compressed, compact or solid)
C. Conductor material (aluminum or copper)
After the cable conductor information has been determined:
1. Locate the X table indicated in the Cat. No. selection chart.
2. Complete the ordering information by selecting and inserting the symbol
(given in the X table) into the Cat. No.
See the Ordering Example on page A33 for further information.
PN ——-WX- ——
“X”
CABLE
CONDUCTOR
Determines Crimp Connector Size
“X”
CABLE
CONDUCTOR
PN ——-WX-
CABLE SHIELD
AND JACKET
Determines Required
Accessories (if any)
• Cable Shield Adaptors
• Cable Grounding Kits
• Cable Jacket Seal
“SUFFIX”
Reference Pages A30 and A31
for application, selection and
ordering information.
CONNECTOR SELECTION GUIDE
Elastimold®Cable Accessories
A35
w w w . t n b . c a
AEIC and ICEA Cable Insulation
Diameter
15 kV 100% – 175 mil Insulation (0.175 in.)
15 kV 133% – 220 mil Insulation (0.220 in.)
25 kV 100% – 260 mil Insulation (0.260 in.)
35 kV 100% – 345 mil Insulation (0.345 in.)
AEIC CS8-06
Specification for Extruded Dielectric,
Shielded Power Cable Rated 5 - 46 kV
AEIC-Calulated Diameters - Solid and Compressed Stranding from
Tables C-4 and C-6 and Compact Stranding from Tables C-5 and C-7
ANSI/ICEA S-94-649-2004 and S-97-682-2000
Standard for Concentric Neutral Cables and
Utility Shielded Power Cables Rated 5 - 46 kV
ICEA-Concentric Stranding Table C-3, Compressed Stranding
Table C-4, Compact Stranding Table C-5
ICEA Abbreviated, for additional cables please refer to the standard.
WALL
W = Insulation Diameter (Conductor + 2 X Conductor Shield + 2 X wall)
15 kV Cable (100% level, 175 mil)
Aluminum
and Copper
Conductor
Size
Industry
Standard
Solid Conductor Stranded Conductor Compressed Conductor Compact Conductor
Diameter (in.)
Over Insulation
Diameter (in.)
Over Insulation
Diameter (in.)
Over Insulation
Diameter (in.)
Over Insulation
Min. Max. Min. Max. Min. Max. Min. Max.
#2 AEIC 0.610 0.700 ––0.635 0.725 0.620 0.710
ICEA 0.610 0.695 0.645 0.730 0.635 0.720 0.620 0.705
#1 AEIC 0.645 0.730 ––0.675 0.765 0.655 0.740
ICEA 0.645 0.725 0.685 0.770 0.675 0.760 0.655 0.735
1/0 AEIC 0.680 0.770 ––0.715 0.805 0.690 0.775
ICEA 0.680 0.760 0.725 0.810 0.715 0.800 0.690 0.775
2/0 AEIC ––––0.760 0.850 0.730 0.815
ICEA ––0.775 0.855 0.760 0.845 0.730 0.815
3/0 AEIC ––––0.810 0.900 0.775 0.865
ICEA ––0.825 0.905 0.810 0.895 0.775 0.860
4/0 AEIC ––––0.865 0.955 0.830 0.915
ICEA ––0.880 0.965 0.865 0.950 0.830 0.910
250 AEIC ––––––––
ICEA ––0.935 1.020 0.920 1.005 0.880 0.965
350 AEIC ––––1.025 1.115 0.980 1.065
ICEA ––1.045 1.130 1.025 1.110 0.980 1.065
500 AEIC ––––1.150 1.245 1.100 1.185
ICEA ––1.175 1.260 1.150 1.235 1.100 1.185
750 AEIC ––––1.340 1.440 1.280 1.370
ICEA ––1.370 1.455 1.340 1.425 1.280 1.365
1000 AEIC ––––1.485 1.590 1.430 1.520
ICEA ––1.520 1.610 1.485 1.575 1.430 1.515
ICEA NOTE: Diameters specified in the above table are different than specified by AEIC CS8-00.
Consult your Regional Sales Office for proper selection of accessories. Diameters to be measured in accordance with 9.6.
Elastimold®Cable Accessories
A36
w w w . t n b . c a
AEIC and ICEA Cable Insulation Diameter
15 kV Cable (133% level, 220 mil)
Aluminum
and Copper
Conductor
Size
Industry
Standard
Solid Conductor Stranded Conductor Compressed Conductor Compact Conductor
Diameter (in.)
Over Insulation
Diameter (in.)
Over Insulation
Diameter (in.)
Over Insulation
Diameter (in.)
Over Insulation
Min. Max. Min. Max. Min. Max. Min. Max.
#2 AEIC 0.700 0.790 ––0.725 0.815 0.710 0.800
ICEA 0.700 0.790 0.735 0.825 0.725 0.815 0.710 0.800
#1 AEIC 0.735 0.820 ––0.765 0.855 0.745 0.830
ICEA 0.735 0.820 0.775 0.865 0.765 0.855 0.745 0.830
1/0 AEIC 0.770 0.860 ––0.805 0.895 0.780 0.865
ICEA 0.770 0.855 0.815 0.905 0.805 0.895 0.780 0.865
2/0 AEIC ––––0.850 0.940 0.820 0.905
ICEA ––0.865 0.950 0.850 0.935 0.820 0.905
3/0 AEIC ––––0.900 0.990 0.865 0.955
ICEA ––0.915 1.000 0.900 0.985 0.865 0.955
4/0 AEIC ––––0.955 1.045 0.920 1.005
ICEA ––0.970 1.060 0.955 1.045 0.920 1.005
250 AEIC ––––––––
ICEA ––1.025 1.115 1.010 1.100 0.970 1.060
350 AEIC ––––1.115 1.205 1.070 1.155
ICEA ––1.135 1.220 1.115 1.200 1.070 1.155
500 AEIC ––––1.240 1.335 1.190 1.275
ICEA ––1.265 1.355 1.240 1.330 1.190 1.275
750 AEIC ––––1.430 1.530 1.370 1.460
ICEA ––1.460 1.550 1.430 1.520 1.370 1.460
1000 AEIC ––––1.575 1.680 1.520 1.610
ICEA ––1.610 1.705 1.575 1.670 1.520 1.610
25 kV Cable (100% level, 260 mil)
Aluminum
and Copper
Conductor
Size
Industry
Standard
Solid Conductor Stranded Conductor Compressed Conductor Compact Conductor
Diameter (in.)
Over Insulation
Diameter (in.)
Over Insulation
Diameter (in.)
Over Insulation
Diameter (in.)
Over Insulation
Min. Max. Min. Max. Min. Max. Min. Max.
#1 AEIC 0.805 0.900 ––0.835 0.935 0.815 0.910
ICEA 0.805 0.895 0.845 0.935 0.835 0.925 0.815 0.905
1/0 AEIC 0.840 0.940 ––0.875 0.975 0.850 0.945
ICEA 0.840 0.930 0.885 0.980 0.875 0.965 0.850 0.940
2/0 AEIC ––––0.920 1.020 0.890 0.985
ICEA ––0.935 1.025 0.920 1.010 0.890 0.980
3/0 AEIC ––––0.970 1.070 0.935 1.035
ICEA ––0.985 1.075 0.970 1.060 0.935 1.030
4/0 AEIC ––––1.025 1.125 0.990 1.085
ICEA ––1.040 1.135 1.025 1.115 0.990 1.080
250 AEIC ––––––––
ICEA ––1.095 1.190 1.080 1.175 1.040 1.135
350 AEIC ––––1.185 1.295 1.140 1.245
ICEA ––1.205 1.295 1.185 1.275 1.140 1.230
500 AEIC ––––1.310 1.425 1.260 1.365
ICEA ––1.335 1.430 1.310 1.405 1.260 1.350
750 AEIC ––––1.500 1.620 1.440 1.550
ICEA ––1.530 1.625 1.500 1.595 1.440 1.535
1000 AEIC ––––1.645 1.770 1.590 1.700
ICEA ––1.680 1.775 1.645 1.740 1.590 1.685
ICEA NOTE: Diameters specified in the above table are different than specified by AEIC CS8-00.
Consult your Regional Sales Office for proper selection of accessories. Diameters to be measured in accordance with 9.6.
Elastimold®Cable Accessories
A37
w w w . t n b . c a
AEIC and ICEA Cable Insulation Diameter
35 kV Cable (100% level, 345 mil)
Aluminum
and Copper
Conductor
Size
Industry
Standard
Solid Conductor Stranded Conductor Compressed Conductor Compact Conductor
Diameter (in.)
Over Insulation
Diameter (in.)
Over Insulation
Diameter (in.)
Over Insulation
Diameter (in.)
Over Insulation
Min. Max. Min. Max. Min. Max. Min. Max.
1/0 AEIC 1.010 1.110 ––1.045 1.145 1.020 1.115
ICEA 1.010 1.110 1.055 1.155 1.045 1.145 1.020 1.120
2/0 AEIC ––––1.090 1.190 1.060 1.155
ICEA ––1.105 1.200 1.090 1.190 1.060 1.160
3/0 AEIC ––––1.140 1.240 1.105 1.205
ICEA ––1.155 1.255 1.140 1.240 1.105 1.205
4/0 AEIC ––––1.195 1.295 1.160 1.255
ICEA ––1.210 1.310 1.195 1.295 1.160 1.260
250 AEIC ––––––––
ICEA ––1.265 1.370 1.250 1.350 1.210 1.315
350 AEIC ––––1.355 1.470 1.310 1.420
ICEA ––1.375 1.475 1.355 1.455 1.310 1.410
500 AEIC ––––1.480 1.600 1.430 1.540
ICEA ––1.505 1.605 1.480 1.580 1.430 1.530
750 AEIC ––––1.670 1.795 1.610 1.725
ICEA ––1.700 1.800 1.670 1.770 1.610 1.710
1000 AEIC ––––1.815 1.945 1.760 1.875
ICEA ––1.850 1.955 1.815 1.920 1.760 1.865
ICEA NOTE: Diameters specified in the above table are different than specified by AEIC CS8-00.
Consult your Regional Sales Office for proper selection of accessories. Diameters to be measured in accordance with 9.6.
Elastimold®Cable Accessories
A38
w w w . t n b . c a
AEIC and ICEA Cable Insulation Diameter
Conductor Diameters for Copper and Aluminum (Class B)
Stranded, Compressed, Compact and Solid Cables
CABLE
CONDUCTOR
Conductor
Size
AWG of kcmil
No. of Strands
and their Nom.
Strand Dia. (in.)
Cross-sectional Area Stranded
Conductors
(in.)
Compressed
Conductors
(in.)
Compact
Conductors
(in.)
Solid
Conductors
(in.)
Square
(in.)
mm2
Conversion
14
12
10
8
6
4
2
7 x 0.0242 0.0032 2.08 0.073 0.064
7 x 0.0305 0.0051 3.31 0.092 0.081
7 x 0.0385 0.0082 5.26 0.116 0.102
7 x 0.0486 0.0130 8.37 0.146 0.129
7 x 0.0612 0.0206 13.30 0.184 0.162
7 x 0.0772 0.0328 21.15 0.232 0.204
7 x 0.0974 0.0521 33.62 0.292 0.283 0.268 0.258
1
1/0
2/0
3/0
4/0
19 x 0.0664 0.0657 42.41 0.332 0.322 0.299 0.289
19 x 0.0745 0.0829 53.49 0.373 0.362 0.336 0.325
19 x 0.0837 0.1054 67.43 0.418 0.405 0.376
19 x 0.0940 0.1318 85.01 0.470 0.456 0.423
19 x 0.1055 0.1662 107.2 0.528 0.512 0.475
250
350
500
37 x 0.0822 0.1964 127 0.575 0.558 0.520
37 x 0.0973 0.2749 177 0.681 0.661 0.616
37 x 0.1162 0.3924 253 0.813 0.789 0.736
600
700
750
800
900
1000
61 x 0.0992 0.4712 304 0.893 0.866 0.813
61 x 0.1071 0.5498 355 0.964 0.935 0.877
61 x 0.1109 0.5890 380 0.998 0.968 0.908
61 x 0.1145 0.6283 405 1.031 1.000 0.938
61 x 0.1215 0.7069 456 1.094 1.061 0.999
61 x 0.1280 0.7854 507 1.152 1.117 1.060
1100
1200
1250
1300
1400
1500
91 x 0.1099 0.8639 557 1.209 1.173
91 x 0.1148 0.9425 608 1.263 1.225
91 x 0.1172 0.9818 633 1.289 1.250
91 x 0.1195 1.021 659 1.315 1.276
91 x 0.1240 1.100 709 1.364 1.323
91 x 0.1284 1.178 760 1.412 1.370
1600
1700
1750
1800
1900
2000
127 x 0.1122 1.257 811 1.459 1.415
127 x 0.1157 1.335 861 1.504 1.459
127 x 0.1174 1.374 887 1.526 1.480
127 x 0.1191 1.414 912 1.548 1.502
127 x 0.1223 1.492 963 1.590 1.542
127 x 0.1225 1.571 1010 1.632 1.583
Elastimold®Cable Accessories
A39
w w w . t n b . c a
Table W1
USE FOR
FOLLOWING
PRODUCTS
151SP/SR
151LS/LY
165/166LR
165/166LRJS
Cable Insulation
Diameter (in.) Symbol
for W
Min. Max.
0.575 0.740 A
0.635 0.905 B
0.805 1.060 C
0.890 1.220 D
Table W2
USE FOR
FOLLOWING
PRODUCTS
273RLR
274RLR
Cable Insulation
Diameter (in.) Symbol
for W
Min. Max.
0.760 0.950 G
0.850 1.050 H
0.980 1.180 J
1.090 1.310 K
Table W3
USE FOR
FOLLOWING
PRODUCTS
375LR
376LR
Cable Insulation
Diameter (in.) Symbol
for W
Min. Max.
0.850 1.050 H
0.980 1.180 J
1.090 1.310 K
1.235 1.465 L
Table W4
USE FOR
FOLLOWING
PRODUCTS
156LR
167/168RLR
167LRT
Cable Insulation
Diameter (in.) Symbol
for W
Min. Max.
0.640 0.820 F
0.760 0.950 G
0.850 1.050 H
0.980 1.180 J
1.090 1.310 K
Table W5
USE FOR
FOLLOWING
PRODUCTS
167/168ELR
273/274ELR
Cable Insulation
Diameter (in.) Symbol
for W
Min. Max.
0.665 0.895 6689
0.740 0.950 7495
0.880 1.100 88110
1.090 1.310 K
Table W7
USE FOR
FOLLOWING
PRODUCTS
K656I/CY/CH
K655/656LR
K655/656SR
655/656LINK
K655/656LINK
655/656ETP
K655/656ETP
655/656RTP
K655/656LRTP
655/656BI-LINK
K655/656BI-LINK
655CA/CK/TCK
Cable Insulation
Diameter (in.) Symbol
for W
Min. Max.
0.640 0.820 F
0.760 0.950 G
0.850 1.050 H
0.980 1.180 J
1.090 1.310 K
1.180 1.465 L
1.280 1.430 LM
1.370 1.630 M
1.515 1.780 N
1.725 1.935 P
Table W8
USE FOR
FOLLOWING
PRODUCTS
15PCJ-1
15PCJ-2
Cable Insulation
Diameter (in.) Symbol
for W
Min. Max.
0.640 0.820 F
0.760 0.950 G
0.850 1.050 H
0.980 1.180 J
1.090 1.310 K
1.180 1.465 L
1.280 1.430 LM
1.370 1.630 M
1.515 1.780 N
1.725 1.935 P
1.900 2.120 Q
Table W9
USE FOR
FOLLOWING
PRODUCTS
25PCJ-1
25PCJ-2
755/756LR
755/756LINK
755/756ETP
755/756LRTP
755/756BI-LINK
755CA/CK/TCK
Cable Insulation
Diameter (in.) Symbol
for W
Min. Max.
0.760 .950 G
0.850 1.050 H
0.980 1.180 J
1.090 1.310 K
1.180 1.465 L
1.280 1.430 LM
1.370 1.630 M
1.515 1.780 N
1.725 1.935 P
1.900 2.120 Q
Table W6
USE FOR
FOLLOWING
PRODUCTS
10EP
152EA
160CA*
(*EB-FA Only)
Cable Insulation
Diameter (in.) Symbol
for W
Min. Max.
0.495 0.585 EB
0.525 0.635 EF
0.575 0.685 FA
0.625 0.735 FAB
0.675 0.785 FB
0.725 0.835 FG
0.775 0.885 GA
0.825 0.935 GAB
0.875 0.985 GB Please see page A28for Table W13 and page A31 for Tables W14 and W15.
WX Size Tables
Elastimold®Cable Accessories
A40
w w w . t n b . c a
WX Size Tables
Table X1
USE FOR
FOLLOWING
PRODUCTS
167/168ELR
273/274ELR
156LR
165/166LR
275/276LR
167LRT
167/168RLR
273/274RLR
00400
02500
02509
02702
02800
K151SP/SR
K151LS/LY
Conductor
Size AWG
or kcmil
Symbol for X
Strand./
Compr.
Compt./
Solid.
#4 200 190
#3 210 200
#2 220 210
#1 230 220
1/0 240 230
2/0 250 240
3/0 260 250
4/0 270 260
250 – 270
Table X2
USE FOR
FOLLOWING
PRODUCTS
375/376LR
Conductor
Size AWG
or kcmil
Symbol for X
Strand./
Compr.
Compt./
Solid.
1/0 240 230
2/0 250 240
3/0 260 250
4/0 270 260
Table X3
USE FOR
FOLLOWING
PRODUCTS
35MTG
NOTE:
SEE PAGE A24
FOR DETAILED
APPLICATION
INFORMATION
Conductor
Size AWG
or kcmil
Symbol for X
Strand./
Compr.
Compt./
Solid.
#6 5
#5 4 5
#4 3 4
#3 2 3
#2 1 2
#1 0 1
1/0 10 0
2/0 20 10
3/0 30 20
4/0 40 30
250 250 40
300 300 250
350 350 300
400 400 350
450 450
500 500 400
550 550 450
600 600 500
650 650 550
700 750 600
750 750 650
800 800 750
900 900 800
1000 1000 900
Table W12
USE FOR
FOLLOWING
PRODUCTS
16THG
16THGS
16THGH
Cable Insulation Diameter (in.) Symbol
for W
Min. Max.
0.495 0.585 EB
0.525 0.635 EF
0.575 0.685 FA
0.625 0.735 FAB
0.675 0.785 FB
0.725 0.835 FG
0.775 0.885 GA
0.825 0.935 GAB
0.875 0.985 GB
0.930 1.040 GH
0.980 1.115 HA
Table W10
USE FOR
FOLLOWING
PRODUCTS
35PCJ-1
35PCJ-2
Cable Insulation Diameter (in.) Symbol
for W
Min. Max.
0.850 1.050 H
0.980 1.180 J
1.090 1.310 K
1.180 1.465 L
1.280 1.430 LM
1.370 1.630 M
1.515 1.780 N
1.725 1.935 P
1.900 2.120 Q
Table W11
USE FOR
FOLLOWING
PRODUCTS
35MSC
35MSCI
Cable Insulation Diameter (in.) Symbol
for W
Min. Max.
0.495 0.585 EB
0.525 0.635 EF
0.575 0.685 FA
0.625 0.735 FAB
0.675 0.785 FB
0.725 0.835 FG
0.775 0.885 GA
0.825 0.935 GAB
0.875 0.985 GB
0.930 1.040 GH
0.980 1.115 HA
1.040 1.175 HAB
1.095 1.240 HB
1.160 1.305 HJ
1.220 1.375 JA
1.285 1.395 JAB
1.355 1.520 JB
1.485 1.595 KA
1.530 1.640 KAB
1.575 1.685 KB
1.665 1.785 PA
1.755 1.875 PB
Table W16
USE FOR
FOLLOWING
PRODUCTS
275/276LR
275/276LRS
Cable Insulation Diameter (in.) Symbol
for W
Min. Max.
0.635 0.905 B
0.800 1.060 CC
0.940 1.170 DD
1.090 1.310 E
Elastimold®Cable Accessories
A41
w w w . t n b . c a
WX Size Tables
Table X3A
USE FOR
FOLLOWING
PRODUCTS
35MTG
NOTE:
SEE PAGE A24
FOR DETAILED
APPLICATION
INFORMATION
Conductor
Size AWG
or kcmil
Symbol for X
Strand./
Compr.
Compt./
Solid.
400 400
450 450 400
500 500 450
550 550 500
600 600 500
650-700 650 550
750 750 600
800 750 650
1000 1000
Table X4
USE FOR
FOLLOWING
PRODUCTS
16THGS
16CAS
Riser Conductor Size
AWG Solid
Symbol
for X
#2 2
#1 2
1/0 10
2/0 20
3/0 30
4/0 30
Table X6
USE FOR
FOLLOWING
PRODUCTS
655/656LRTP
K655/656LRTP
755/756LRTP
K656I/Y/H
K655/656LR
755/756LR
K655/656SR
655/656LINK
K655/656LINK
755/756LINK
655/656ETP
K655/656ETP
755/756ETP
655/656BI-LINK
K655/656BI-LINK
755BI-LINK
655CK
755CK
655TCK
03600
03602
03700
03702
Conductor
Size AWG
or kcmil
Symbol for X
Strand./
Compr.
Compt./
Solid.
#2 220 210
#1 230 220
1/0 240 230
2/0 250 240
3/0 260 250
4/0 270 260
250 280 270
300 290 280
350 300 290
400 310 300
450 320 310
500 330 320
550 340 320
600 350 330
650 360 340
700 380 350
750 380 360
800 390 360
900 400 380
1000 410 400
1250 440 420
Table X7
USE FOR
FOLLOWING
PRODUCTS
15PCJ1
25PCJ1
35PCJ1
15PCJ2
25PCJ2
35PCJ2
Conductor
Size AWG
or kcmil
Symbol for X
Strand./
Compr.
Compt./
Solid.
#6 180
#5 190 180
#4 200 190
#3 210 200
#2 220 210
#1 230 220
1/0 240 230
2/0 250 240
3/0 260 250
4/0 270 260
250 280 270
300 290 280
350 300 290
400 310 300
450 320 310
500 330 310
550 340 320
600 350 330
650 360 340
700 380 350
750 380 360
800 390 380
900 400 380
1000 410 400
1250 440 420
Table X8
USE FOR
FOLLOWING
PRODUCTS
16THG
16TCA
Conductor
Size AWG
or kcmil
Symbol for X
Strand./
Compr.
Compt./
Solid.
#6 180
#5 190 180
#4 200 190
#3 210 200
#2 220 210
#1 230 220
1/0 240 230
2/0 250 240
3/0 260 250
4/0 270 260
Table X9
USE FOR
FOLLOWING
PRODUCTS
PCT1
PCT2
01000
01010
Conductor
Size AWG
or kcmil
Symbol for X
Strand./
Compr.
Compt./
Solid.
#2 220 210
#1 230 220
1/0 240 230
2/0 250 240
3/0 260 250
4/0 270 260
Elastimold®Cable Accessories
A42
w w w . t n b . c a
Shrink-Fit Cable Joints
The Faster, Easier Way to Splice Medium-Voltage Cables in
Direct-Burial, Underground or Overhead Applications.
Features
Automatic core removal without ripcords or heat required for installation
High-quality molded EPDM elastomer housing withstands the elements in harsh
direct-burial, vault, manhole and overhead applications
Four sizes support a wide range of cable and conductor sizes
IEEE 404 rated shrink-fit cable joint
Typical Applications
Direct Burial
• Handhole/Pullbox
• Manhole
• Vault
• Overhead
For over 50 years, the Elastimold®brand has been associated with reliable, high-quality,
pre-molded power cable splices that are designed to stand the rigors of the toughest utility
applications. These products provide a cost-effective method to splice medium voltage cables
using a “push-on” motion, and allowing cable neutrals to be solidly connected across the body
of the splice without the use of any external braids. For those who prefer a more range-taking
solution without the use of any physical force to install, the only options available have been
cumbersome heat-shrink products that require multiple steps and the use of an open flame that
may not result in uniform cable coverage, or over-designed cold-shrink products that either use
awkward, entangling ripcords or expensive braid/jacket combinations that do not offer the ability
to solidly connect neutrals across the splice.
Now there’s a faster and easier way to splice medium-voltage cables — one that combines all
of the convenience and flexibility of a pre-molded splice, with the range-taking ease of
installation offered in a cold- or heat-shrink product, but without the use of ripcords, heat or
excessive force. Introducing, the NEW Elastimold®Shrink-Fit Cable Joints from Thomas & Betts!
The Shrink-Fit Cable Joints are made of the same molded EPDM elastomer as our other
Elastimold®cable accessories. This high-performance material offers more durability than
silicone for direct burial. The joints feature a four-piece plastic support core, which is placed over
the cable for installation of the splice. The support core is then easily removed with the supplied
tool, allowing the elastomer joint to contour over the spliced cable for a uniform seal every time.
Each Elastimold®Shrink-Fit Cable Joint covers a wide range of cable sizes, features an
insulated, semi-conductive shield and can be used with either a standard aluminum or optional
copper compression splice. Optional kits are available for neutral, shielding and jacket
restoration.
SFJ115
Shrink-Fit Cable Joint
SFJ415
Shrink-Fit Cable Joint
Disposable four-piece plastic support core
Elastimold®Cable Accessories
A43
w w w . t n b . c a
Shrink-Fit Cable Joints
Installation Sequence
Place Elastimold®Shrink-Fit
Joint in position.
Install connector. Cut fastening straps. Automatic core
detachment begins.
Crimp grounding wires.
Last core piece detaches.
Core automatically detaches
from second end.
Core pushes itself towards the
ends of the Shrink-Fit Joint.
Volt Class 15 kV 25/28 kV 35 kV
Max. Phase-to-Ground Operating Voltage 8.7 kV 14.4 kV 20.2 kV
BIL Impulse Withstand (1.2 x 50μsec. wave) 110 kV 150 kV 200 kV
Corona Extinction Level @ 3.0 pC Sensitivity 13 kV 22 kV 30 kV
DC Withstand during Installation 56 kV 80 kV 100 kV
DC Withstand up to 5 yrs.* — XLPE Insulation 18 kV 25 kV 31 kV
DC Withstand up to 5 yrs.* — EPR Insulation 45 kV 64 kV 80 kV
AC Withstand at 60 Hz for 60 sec. 35 kV 52 kV 69 kV
Continuous Current Equal to that of cable
Short-Term Current Equal to that of cable up to 35 kA
*Reference: AEC CS6 and CS8, section L.2.
Ratings
Cable
Joint Size
D
(in.)
L
(in.)
1 1.85 11
2 2.12 16
3 2.4 18
4 2.6 18
Dimensions
Cable
Joint Size
Min.
(in.)
Max.
(in.)
Min.
(mm)
Max.
(mm)
1 0.620 0.780 15.75 19.81
2 0.815 0.920 20.70 23.37
3 0.935 1.190 23.75 30.23
4 1.210 1.760 30.73 44.70
Insulation Range
How to construct a catalogue number for an Elastimold®Shrink-Fit Cable Joint:
SF J
Voltage Rating
15 11 kV
25 25/28 kV
35 35 kV
Connector Type
CCrimp
Conductor
1Aluminum
2Copper
Cable Joint Size
Size
Code
Wall
Thickness
(mils)
Min.
Conductor
Size*
Max.
Conductor
Size*
15 kV
1
175
#2 AWG 3/0 AWG
24/0 AWG 250 kcmil
3350 kcmil 600 kcmil
4700 kcmil 1000 kcmil
1
220
#2 AWG 1/0 AWG
22/0 AWG 4/0 AWG
3250 kcmil 500 kcmil
4600 kcmil 1000 kcmil
25/28 kV
2
260
#1 AWG 2/0 AWG
33/0 AWG 350 kcmil
4500 kcmil 1000 kcmil
35 kV
3345 1/0 AWG 4/0 AWG
4250 kcmil 1000 kcmil
Connector Size
X
Code
Conductor Size
(AWG or Kcmil)
Stranded/
Compressed
Solid/
Compact
210 #2 AWG
220 #2 AWG #1 AWG
230 #1 AWG 1/0 AWG
240 1/0 AWG 2/0 AWG
250 2/0 AWG 3/0 AWG
260 3/0 AWG 4/0 AWG
270 4/0 AWG 250 kcmil
280 250 kcmil 300 kcmil
290 300 kcmil 350 kcmil
300 350 kcmil 400 kcmil
310 400 kcmil 500 kcmil
330 500 kcmil 650 kcmil
360 650 kcmil 750 kcmil
380 750 kcmil 900 kcmil
400 900 kcmil 1000 kcmil
410 1000 kcmil
* Based on the minimum compact AEIC and ICEA cable insulation diameters.
Note: Each kit contains shrink-fit housing on removable core, splice connector,
lubricant, installation instructions and crimp chart. For ordering information on
optional neutral, shielding and jacket restoration kits, please contact your Regional
Sales Office.
Elastimold®Cable Accessories
A44
w w w . t n b . c a
Ranger2Terminations
Overview
Elastimold®Ranger2TM Terminations are specifically designed for use on 15 thru 35 kV, XLP or
EPR insulated, underground power distribution cable systems. Units allow proper transition and
connection of the underground cable system to bare overhead conductors and live front
equipment. Applications include indoor, outdoor, riser pole, padmounted and other live front or
weather exposed installations. Designs use advanced silicone rubber insulating materials to
provide necessary creep, strike, weather sealing and contamination resistance, assuring proper
performance in the most severe conditions. The grey color blends in with outdoor environments.
Ranger2 Terminations support a wide application range with only three sizes required to cover
#2 AWG through 1250 kcmil cables. The single-piece 15 kV and 25 kV shrink-fit design makes
installation effortless, and the two-piece 35 kV design facilitates easier core removal. Simply
position the terminator on the prepared cable and remove the center core. Units are compact
and lightweight, allowing installation in restricted spaces and free-hanging applications.
Silicone Polymer Housings
The R2T and R2IT terminations are manufactured using an optimized weather-resistant silicone formulation. The housing offers superior cable
sealing and voltage withstand characteristics. Elastimold terminations meet or exceed all requirements of IEEE Standard 48 for Class 1 outdoor
or Class 2 indoor terminations. Unit tests include voltage withstand wet and dry, before and after load cycling on units installed on maximum
conductor sized cable.
Kit Contents
Every R2T and R2IT comes complete with housing and stress tube
preassembled on the core, ready for installation. Easy-to-read
installation instructions will take you from cable preparation through
installation. All kits include a tube of silicone grease, two plastic
gloves and one strip of self-fusing silicone tape. Outdoor kits also
include mastic for sealing. Metallic Tape (M) kits include a grounding
adapter for Tape Shield, Wire Shield and UniShield cables. LC Shield
(L) kits include a high ampacity grounding adapter for Longitudinally
Corrugated Shield, Tape Shield and Wire over Tape Shield cables.
Stress Relief
The R2T and R2IT terminations provide electric stress control for the cable by means of a flexible tube with a high permittivity dielectric
constant. The stress-relief tube is preassembled on the core under the polymer housing. As the core is removed, the stress-relief tube and
housing shrink onto the cable at the same time, in exactly the right position. No secondary operations are required during installation. The
electrical fields are refracted through the high dielectric constant tube and housing as shown.
Installation
Standard cable preparation techniques are used for all R2T, Elastimold Ranger2 Outdoor Terminations, and R2IT, Elastimold Ranger2 Indoor
Terminations. The Elastimold shrink-fit terminations are assembled on a removable core. After the termination is placed onto the prepared
cable, the core is removed by pulling on the end. The housing then collapses onto the prepared cable. Memory of the material provides the
interface solid dielectric and sealing properties required to meet the electrical ratings and prevent the ingress of moisture.
Stress Relief
Voltage Stress
Terminal Housing Terminal Stress Relief
Cable Insulation Conductor
Cable Semi-Conductor
1
2
3
4
5
1
2
3
4
5
Elastimold®Cable Accessories
A45
w w w . t n b . c a
Ranger2Terminations
Overview
Features Benefits/Descriptions
Silicone Polymer Housing Superior memory and weathering characteristics
Shrink-Fit Housing Uses common installation procedures and cable preparation dimensions. Field-removable center core allows for easy installation.
Three Different Shed Designs for Superior Weathering
• Four sheds for 15 kV outdoor model
• Six sheds for 25/28 kV outdoor model
• Eight sheds for 35 kV outdoor model
Wide Range Three sizes cover entire cable range from #2 AWG to 1250 kcmil. Units accommodate popular XLP and EPR cable types and shield constructions.
Integral Hi-K Voltage Stress-Control Tube Provides uniform voltage grading over the length of the termination. Eliminates damaging voltage stress concentrations at the cable insulation
shield edge. Thick wall construction securely maintains critical interface pressure for consistent long term reliability and performance.
Pull-Down Tabs for Easy Installation of Built-In Jacket Seal Accommodates CN, JCN, Tape, Wire or LC shielded cable construction
Lightweight, Compact Design Installs in restricted spaces. Permits application where free hanging is desired.
Dark Grey Molded Silicone Insulator
Blends well into outdoor environments. Utilizes specially formulated silicone materials with improved UV stability, track, erosion and weather
resistance. Outdoor styles feature large diameter, multi-shed profile with extra creep and strike for enhanced performance under the worst
environmental conditions.
Optional Connectors Connector with copper stem, one-hole and two-hole spade connector
Optional Cable and Support Bracket Three sizes, ranging from 0.80 in. – 1.95 in. O.D.
Typical Installation on Jacketed Concentric Neutral (JCN) Cable
IEEE 48 Standard for indoor and outdoor cable terminations
ANSI C119.4 Standard for cable connectors for aluminum and copper conductors
AEIC CS8-06 and ANSI/ICEA S-94-649-2004
and S-97-682-2000 Standards for XLP and EPR insulated cables
Elastimold Ranger2 Terminations have been designed and tested per
applicable portions of ANSI, IEEE, AEIC, ICEA and other industry standards.
Certified
Connector
Grey Molded
Silicone Insulator Built-In Cable
Entrance Seal Cable Jacket
Concentric Neutral Wires
Mastic
Cable
Shield
Hi-K Voltage
Stress-Control Tube
Cable
Insulation
Silicone
Tape Seal
Ratings Indoor Outdoor Outdoor Outdoor
Termination Catalogue Series R2IT15 R2T15 R2T28 R2T35
Sizes Available* 1, 2, 4 1, 2, 4 2, 4 2, 4
Voltage Rating (kV) 15 15 25/28 35
Max. Design Voltage to Ground (kV) 9.5 9.5 16 22
Corona Extinction Voltage (kV) (≤3 p.c.) (Partial Discharge) 13 13 22 30
Insulation Withstand Voltage:
Lightning Impulse (BIL Dry 110 Withstand) (kV Crest) 110 110 150 200
10 Sec. Wet (60 Hz) (kV) — 45 60 80
1 Minute Dry (60 Hz) (kV) 50 50 65 90
5 Hour Dry (60 Hz) (kV) 36 35 55 75
DC Withstand 15 Min. Dry (kV) 75 75 105 140
Ratings
Dimensions Indoor Outdoor Outdoor Outdoor
Termination Catalogue Series R2IT15 R2T15 R2T28 R2T35
Sizes Available* 1, 2, 4 1, 2, 4 2, 4 2, 4
Voltage Rating (kV) 15 15 25/28 35
Number of Sheds 0 4 6 8
Minimum Strike Distance in. (mm) 8.4 (213) 11.6 (295) 14.5 (368) 16.8 (427)
Creepage Distance in. (mm) 15.0 (381) 22.8 (579) 30.0 (762)
Dimensions
IEEE 48 Classification Outdoor = Class 1A, Indoor = Class 2
Ambient Temperature Range -30ºC to 65ºC
Power System Frequency 48 to 62 Hz
Altitude Range 3 300 ft. max.
Mounting Free hanging or optional bracket
Application Information
* See page A46 for cable insulation diameter ranges. * See page A46 for cable insulation diameter ranges.
Elastimold®Cable Accessories
A46
w w w . t n b . c a
Ranger2TM Terminations
Base Catalogue Numbers
The R2T and R2IT termination design couples shrink-fit technology and Elastimold’s pull-down jacket seal feature to provide a termination line
that covers the widest range of applications with the fewest number of models. Three sizes cover 0.64 in. (16 mm) to 2.10 in. (53 mm)
insulation diameter cables (#2 AWG through 1250 kcmil).
The R2T housings are designed for maximum performance in all field conditions with superior creepage and strike distances for long-
term service. Insulating silicone sleeves are also available when more creepage is required or when wildlife protection is needed to insulate the
connectors. Contact your Thomas & Betts Sales Representative for further information.
kV
Class Type
Cable Range
(Insulation
Diameter)
Cat. No.
(in.) mm
Concentric Neutral and
Jacketed Concentric
Neutral Cable
Tape Shield, Wire Shield
and UniShield Cable
LC Shield, Wire over Tape
Shield and Tape Shield Cable
15 Indoor
0.64 to
1.12
16.3 to
28.4 R2IT15J1 R2IT15M1 R2IT15L1
0.84 to
1.38
21.3 to
35.1 R2IT15J2 R2IT15M2 R2IT15L2
1.30 to
2.10
33.0 to
53.3 R2IT15J4 R2IT15M4 R2IT15L4
15 Outdoor
0.64 to
1.12
16.3 to
28.4 R2T15J1 R2T15M1 R2T15L1
0.84 to
1.38
21.3 to
35.1 R2T15J2 R2T15M2 R2T15L2
1.30 to
2.10
33.0 to
53.3 R2T15J4 R2T15M4 R2T15L4
25/28 Outdoor
0.84 to
1.38
20.3 to
35.1 R2T28J2 R2T28M2 R2T28L2
1.30 to
2.10
33.0 to
53.3 R2T28J4 R2T28M4 R2T28L4
35 Outdoor
0.84 to
1.38
20.3 to
35.1 R2T35J2 R2T35M2 R2T35L2
1.30 to
2.10
33.0 to
53.3 R2T35J4 R2T35M4 R2T35L4
Elastimold®Cable Accessories
A47
w w w . t n b . c a
Ranger2TM Terminations
Accessories Connector Options
Type Material Conductor Conductor Size Connector Prefix*
Stem Compression
Connector Aluminum
Aluminum or Copper
#2 through 4/0
(34–107 mm2)
T0
Aluminum Only T1
One-Hole
Spade Connector Tinned Aluminum Aluminum or Copper #2 through 500 kcmil
(34–253 mm2)H0
Two-Hole
Spade Connector Tinned Aluminum Aluminum or Copper #2 through 1250 kcmil
(34–633 mm2)N0
* See page A48 for conductor code.
Cable Support Bracket Options
Ranger2 Terminations are compact, lightweight and frequently allow use of free-hanging mounting methods.
Optional cable support brackets are available if required.
Optional Cable Support Brackets
Type Cable Range (in.)
(Overall O.D.) Cat. No. Suffix No.
Single Clamp 0.80–1.25 (20–32 mm) JB-1 B1
Single Clamp 1.10–1.50 (28–38 mm) JB-2 B2
Double Clamp 1.45–1.95 (37–50 mm) JB-3 B3
Elastimold®Cable Accessories
A48
w w w . t n b . c a
How to construct a catalogue number for Ranger2 Terminations:
Housing Only
Type
Outdoor R2T
Indoor R2IT
Conductor
Code
Stranded or
Compressed
Compact or
Solid
210 – #2
220 #2 #1
230 #1 1/0
240 1/0 2/0
250 2/0 3/0
260 3/0 4/0
270 4/0 250
280 250 300
290 300 350
300 350 400
310 400 500
330 500 600
360 650 750
380 750 900
400 900 1000
410 1000 –
440 1250 –
Ranger2TM Terminations
Ordering Information
Add a connector Add a cable support bracket
XXX XX X X XX XXX
XX
kV Code
15 kV 15
25/28 kV 28
35 kV 35
Cable Type
JConcentric Neutral/Jacketed
Concentric Neutral
MTape Shield/Wire Shield/
UniShield
LLC Shield Tape Shield/Wire
Over Tape Shield
Insulation Range
10.64 in.–1.12 in.
(16 mm–28 mm) (15 kV only)
20.84 in.–1.38 (21 mm–35 mm)
(15 kV, 25 kV, 35 kV)
41.30 in.–2.10 in. (33 mm–53 mm)
15 kV, 25 kV, 35 kV)
Connector Type
T0 Universal Aluminum Barrel for AL or CU
conductor w/Copper Wire Lead #2–4/0
T1 Aluminum Barrel for AL conductor only
w/Copper Wire Lead #2–4/0
H0 Aluminum 1-Hole Spade #2–750 kcmil
N0 Aluminum 2-Hole Spade #2–1250 kcmil
Cable Mounting Bracket
B1 0.80–1.25 (20–32)
B2 1.10–1.50 (28–38)
B2 1.45–1.95 (37–50)
Connector only
Step 1. Select
the Termination
Housing:
A. Select Outdoor or
Indoor housing style
B. Select applicable
voltage class
C. Select neutral/
shield type
D.Select the size
based on the cable
insulation diameter*
Step 2. Select the
Connector:
E. Select desired
connector
F. Select connector code
based on conductor
size and conductor
type
Step 3. Select the
Cable Support
Bracket:
G. Select cable support
bracket based on the
overall O.D. of the
cable
Connector Option
Cable Support
Bracket Option
* To help in selecting the proper terminator, ICEA and AEIC standard dimensions for XLP and EPR cables are shown in pages A35 to A37.
Elastimold®Cable Accessories
A49
w w w . t n b . c a
Ranger2TM Terminations
Installation
Typical Installation of Elastimold Shrink-Fit Terminations (R2T — Outdoor and R2IT — Indoor)
5. Apply a liberal bead of silicone
lubricant to the semi-conshield step.
6. Pull the loose end of the core cord until
the core is even with the end of the
termination housing.
7. Position the terminator onto the cable.
8. Shrink into place by unwinding the
removable core.
9. Apply silicone lubricant to skirt and
mastic area.
10.Fold down the skirt over the mastic to
seal the cable entrance. 11.Seal the top of the terminator at the
connector area with silicone tape.
12.Attach the neutral wires or optional
ground braid to the system ground per
local code. Install the optional cable
support bracket if required.
1. Train the cable into position and cut to length.
Using standard practices, cut back the cable
jacket, metallic shield, semi-conductive shield
and cable insulation, exposing the conductor.
2. Finish preparing the metallic shield. For
concentric neutral or jacketed concentric
neutral cables, bend back the neutral wires
and seal with mastic strips and vinyl tape.
For metallic tape, drain wire, UniShield or
LC Shield cables: install the ground braid
using the constant force spring and seal
with mastic strips and vinyl tape.
3. Clean the exposed conductor, install and crimp
the connector.
4. Use mastic and vinyl tape to fill any gap or
step between the connector and the cable
insulation. Clean the cable.
1234 5 6
8
7
9
10 11 12
Fisher Pierce®Cable Accessories
A50
w w w . t n b . c a
Faulted Circuit Indicators
Series 1548 Overhead FCIs
FCIs with Radio Transmitters
Series 1548 radio FCIs can signal faults to handheld receivers, radio receivers and the
SmartLinkSeries 5000 cellular remote terminal unit (RTU) systems integrated with SCADA
and web-based reporting systems. Status, alarms and other event notifications can be
integrated into SCADA systems, as well as sent to customer-designated personnel via e-mail,
pager or text message. Having precise fault information reduces outage duration, improves
system reliability and lowers operation costs.
Reliable fault indication for single-phase overhead applications
Trip/Reset Tool AT2186-10
Manual trip/reset test for both
permanent and temporary fault
indication using hotstick-mountable
reset tool.
Swipe Here
Trip Logic Adaptive or fixed current trip with inrush restraint logic. Adaptive trip
logic eliminates the need for trip-rating selection or revision with
changing load.
Reset Logic Automatic reset with return of load current and/or time reset of
permanent fault indication. Automatic time reset for temporary fault indication.
Manual trip test and reset capabilities using hotstick-mountable trip/reset tool.
Fault Indication Visual indication choices of LED, 5-LED Array, Flag or Strobe
Light. Highly viewable 360º indication (Strobe or LED). Radio fault reporting
capability also available.
Mounting Hotstick mounting with automatic torque limiting.
Replaceable Lithium Battery Offers 10-year, maintenance-free service life.
(Note that Flag model has non-replaceable battery).
Supports a Wide Range of Conductors Mounts on conductors with diameters
from 0.14 in. to 1.20 in. (3.56 mm to 30.48 mm).
Optional Features Available Options include temporary/permanent fault
indication, instantaneous recloser coordination feature and backfeed restraint
using a delay-trip scheme (requires protective device to pass two cycles
minimum of fault current before closing).
Technical Specifications
Fault Registration: Red, high-intensity LED with choice of hard-wired or fiber optic cable
remote mounting or audible intermittent beeper signal
Trip current: Factory preset to customer specifications within range of 50 A and 100 A to
1,500 A in 100 A increments
Trip Current Accuracy: ±10% of trip rating (calibrated using 1 in. dia. cable for 400 A
trip or less or 2.0 in. dia. cable for greater than 400 A trip)
Trip Response Speed: Consult trip curves (coordinated to properly applied link,
expulsion, power and current-limiting fuses)
Reset Time: 4 hrs., 2 hrs., 1 hr., manual trip/reset standard
Overload Capacity: Capable of withstanding 25,000 A for 10 cycles
Continuous Load Current: Rated at 1,000 A max.
Temperature Range: -40°C to 85°C
Submersibility: Tested to 30 ft.
Operating Battery Life: 800 hrs. for LED indication, 160 hrs. for audible indication,
both with 10-yr. life at 20°C
Battery: Long-life lithium cell
Cable Ranges: 0.63 in. (16 mm) to 1.58 in. (40 mm); 1.58 in. (40 mm)
to 2.36 in. (60 mm); 2.36 in. (60 mm) to 3.55 in. (90 mm)
Remote Fiber Optic Options: Permanent or removable (10 ft. standard, 30 ft. max.)
Certifications: Complies with ANSI/IEEEE 495-1986
Fisher Pierce®Cable Accessories
A51
w w w . t n b . c a
Faulted Circuit Indicators
Underground/Padmount Faulted Circuit Indicators
Series 1541/42/43 Automatic Time Reset FCIs
The following diagram shows how to construct a catalogue number for Series 1541/1542/1543 FCIs.
Not all combinations are possible; consult your Regional Sales Office for ordering assistance.
Indicates field that must be filled in to complete order.
NOTE: Availability of selected configuration will be verified at quotation time.
5 4
Basic Model
1541 Single-Phase
1542 Two-Phase
1543 Three-Phase
Indication/Battery
Options
HLED, non-replaceable battery, hotstick mounted
RLED, replaceable battery, hotstick mounted
AAudible alarm indication, replaceable
battery, hotstick mounted
Inrush Restraint
FInrush time overcurrent
(dual curve) standard
NNon-inrush delay
1B
Trip Point
0.5 50 A
0.6 60 A
1100 A
2200 A
3300 A
4400 A
4.5 450 A
5500 A
6600 A
8800 A
10 1000 A
12 1200 A
15 1500 A
Cable Clamp Size
SSmall 0.63 in.–1.58 in. cable dia.
MMedium 1.58 in.–2.36 in. cable dia.
LLarge 2.36 in.–3.55 in. cable dia.
Display Options
RRemote LED
T
Integral LED or audible alarm (always
selected with code “A” or “H” under
Indication/Battery Options)
ERemote LED, fiber optic cable
FRemote LED, removable fiber optic cable
Length of Remote LED Cable
NNot applicable when code “T” is
selected under Display Options
10 Remote LED, removable fiber optic cable
Reset Time Delay After Fault Occurrence
A4-hr. automatic reset time delay
B2-hr. automatic reset time delay
C1-hr. automatic reset time delay
Cable Accessories
A52
w w w . t n b . c a
Faulted Circuit Indicators
Test Point Fault Indicators TPM Series
Mount directly to any IEEE 386 standard capacitive test point.
Test Point Mounted Fault Indicators consist of a solid-state current sensor connected to a
faulted-circuit display, providing a clear visual means for quickly locating faulted cables and
equipment on underground distribution systems. Designs incorporate advanced circuit logic and
monitoring system protection operation to prevent the indicator from tripping unless an
overcurrent condition is followed by a loss of system voltage. Trip and reset operations are
automatic, and for versatility and convenience, the same indicator may be used for 5 kV thru
35 kV applications.
AccQTripLogic Circuitry Prevents false indications in voltage-reset units due to inrush currents,
cold load pickup and overloading.
High/Low Trip-Setting Selection Requires no minimum load current and no load surveys.
Internal Magnetic Shielding Prevents adjacent phase effects.
1 msec. Trip Response Coordinates with current-limiting fuses, as well as other protection devices.
Magnetically Latched Flag Prevents flag indication from changing state due to shock or vibration.
Test Point Mounting Mounts directly to 200 and 600 A elbows, splices and other cable accessories
equipped with IEEE 386 standard capacitive test points.
Built-In Pulling Eye Enables safe, easy hotstick installation and removal from test points.
Durable Construction Enclosed in a rugged, yet lightweight and compact, sealed, impact- and corrosion
resistant Lexan housing with EPDM molded-rubber test point mounting boot.
Basic Operation
A faulted circuit produces an associated magnetic field, which closes a reed switch in the indicator, resulting in a tripped display. Trip response
occurs in .001 seconds (1 msec.), allowing the fault indicator to properly coordinate with all types of circuit-protection schemes, including
current limiting fuses. To eliminate confusing false trips, voltage-reset indicators are equipped with inrush, backfeed, overload and cold-load
pick-up restraint circuitry. Current sensors feature internal shielding to prevent inadvertent tripping when located in close proximity to adjacent
phases, such as in junction-mounted applications.
Fisher Pierce®
Trip Point VS. Cable Diameter
Time/current Curve for TPMVF, VL, VOL,TL
Cable Accessories
A53
w w w . t n b . c a
Faulted Circuit Indicators
Test Point Fault Indicators TPM Series
Cat. No. Description
TPMTL-[ _ ] Time Reset with LED Display (auto-resets to normal after 4 hrs.; may also be manually reset using an FTT test tool)
TPMVF-[ _ ] Voltage Reset with Flag Display (auto-resets to normal after system voltage restoration; reset requires 5 kV min. voltage with time required for reset proportional to system voltage)
TPMVL-[ _ ] Voltage Reset with LED Display (auto-resets to normal after system voltage restoration; reset requires 5 kV min. voltage with time required for reset proportional to system voltage)
TPMVOL-[ _ ] Voltage Operated, Time Reset, LED Display (auto-resets after 4 hrs.; longer time resets available upon request)
Cat. No. Suffix Description
-LT For 200 A. All fused taps use LOW trip rating. For URD applications, use LOW trip rating.
-HT For 600 A. For URD applications, use HIGH trip rating.
NOTE: For overhead bulk feeder applications, use HIGH or LOW trip ratings (whichever is greater than the minimum pickup setting of the related protection device).
AccQTripand AccQClampare trademarks of Quality Indications, Inc.
(all dimensions (in.) with millimeter equivalents in parentheses)
Test Point
Pulling Eye
for Hotstick
Installation
and Removal
Faulted Circuit
Display
Test Point Mounting Plug
3-7/8
(98)
1-1/8
(29)
1-3/8
(35)
2-1/4
(57)
3-1/4
(83)
Fisher Pierce®
Cable Accessories
A54
w w w . t n b . c a
Fisher Pierce®
Faulted Circuit Indicators
Overhead Line Fault Indicators OLM Series
Locate faulted circuits and equipment on overhead distribution systems
Self-powered Fisher Pierce®Series OLM Overhead Line Fault Indicators consist of a solid-state
current sensor connected to a faulted circuit display. Advanced circuit logic monitors system
protection operation and prevents indicator tripping unless an overcurrent condition is followed by
a loss of system voltage. Trip and reset operations are automatic, and the same indicator may be
used for 5 kV thru 35 kV line-to-ground applications. These compact, sealed and
corrosion-resistant units are designed for direct installation to an overhead line using a
spring-loaded, over-center toggle clamp. Equipped with retainer pads to prevent slip and twist, the
clamp positions the conductor at a constant distance from the current sensor, maintaining trip
accuracy over the entire conductor diameter range of .4 in. to 2.2 in.
Basic Operation
A faulted circuit produces a magnetic field, which closes a reed switch in the indicator and causes
a tripped display. A trip response time of .001 seconds enables the indicator to properly coordinate
with all circuit-protection schemes, including current-limiting fuses. To eliminate confusing false
trips, indicators feature inrush, overload and cold-load pickup restraint circuitry as standard.
Internal shielding of current sensors prevents inadvertent tripping when in close proximity
to adjacent phases.
AccQTrip™ Logic Circuitry In voltage reset units prevents
false indications due to inrush currents, cold load pickup
and overloading.
AccQClamp™ Mounting Provision Universal one-size-fits-
all design automatically adjusts.
High/Low Trip Setting Selection No minimum load current
requirement and no load surveys needed.
Trip Response of .001 Seconds Coordinates with current-
limiting fuses, as well as other protection
devices.
Internal Magnetic Shielding Prevents adjacent phase
effects.
Magnetically Latched Flag Indication Flag indication will
not change states due to shock or vibration.
Lightweight Enclosure Compact and sealed.
Trip Point VS. Cable Diameter
Time/current Curve for OLMVF, VL, VOL,TL
3-7/8
(98)
1-1/8
(29)
1-1/8
(29)
4-1/4
(108) 4-1/4
(108)
Open
2-1/4
(57)
5-5/8
(143)
open
2-3/8
(60)
Open
Cable Accessories
A55
w w w . t n b . c a
Faulted Circuit Indicators
Fisher Pierce®
Overhead Line Fault Indicators OLM Series
Cat. No. Description Reset Operation
OLMTL Time Reset with LED Display Indicator auto-resets to normal after a four hour time duration. indicator may also be manually reset using an FTT test tool.
OLMVF Voltage Reset with Flag Display Indicator auto-resets to normal after system voltage restoration. Reset requires 5 kV minimum voltage to operate.
Reset operation time is proportional to system voltage.
OLMVL Voltage Reset with LED Display Example: at 15 kV, reset occurs 30 seconds after system voltage restoration.
OLMVOL Voltage Operated, Time Reset, LED Display Indicator auto-resets after a four hour time duration. Longer time resets are available upon request.
Cat. No. Suffix Description
LT All fused taps use LOW trip rating. For 600 A Overhead applications, use LOW trip rating.
HT For 600 A Overhead applications, use HIGH trip rating.
Accessories for Series TPM, VCM and OLM Fault Indicators
FO-Cable06
Remote Fiber Optic Indicator for Underground Fault Indicators with LED Display can be extended to the outside of
enclosures and/or vaults for ease of access and fault location. All the hardware for mounting the remote
end of the cable to the enclosure is included. The display has a large reflective bolt
to enhance visibility.
FTT (Field Test Tool)
Permits field testing and reset of fault indicators and provides assurance that the
indicator is properly functioning. The test tool is lightweight, portable and
incorporates a built-in magnet which operates the indicator trip and reset
functions. The unit is equipped with provisions for hotstick handling
and operation.
Cat. No. Description
FTT Field Test Tool, overall dimensions 2 in. wide x 3 in. high x 5⁄8 in. deep
FO-CABLE06 Remote Fiber Optic Indicator for UFI
Cable Accessories
A56
w w w . t n b . c a
Faulted Circuit Indicators
Fisher Pierce®
Voltage Flash Rate
5 kv 20
10 kv 40
15 kv 70
20 kv 100
Voltage Flash Rate
25 kV 140
30 kV 160
35 kV 180
2 (51)
1-3/4
(44)
3-1/4
(44)
3/8
(10)
The V2 Voltage Indicator consists of a self-powered voltage sensor connected to a neon light that
flashes when energized. Simply plug it into any IEEE 836 standard capacitive test point to
determine the energized status of underground distribution circuits. Because the flash rate is
proportional to the phase-to-phase system voltage, as indicated in the chart, one V2 model
supports a wide range of applications – from 5 to 35 kV.
Test Point V2 Voltage Indicator
Easy way to visually determine the energized status of
underground distribution circuits
Test Point
Pulling Eye for
Hotstick Installation
and Removal
EPDM Molded
Rubber Housing
(all dimensions in inches with millimeter equivalents in parentheses)
Flashing Neon
Light Indicates
Energized Status
Test Point
Mounting Plug
Cable Accessories
A57
w w w . t n b . c a
Elastimold®
Wide Application Range Single model supports
applications from 5 kV to 35 kV.
Easy to Read Flash rate per minute indicates system
voltage (see chart).
IEEE 386 Test Interface Mounts to 200 and 600 A
elbows, splices and other cable accessory components
equipped with IEEE 386 capacitive test points.
Rugged Construction Molded EPDM-rubber housing for
shielded, sealed and corrosion-resistant construction.
Built-In Pulling Eye Enables safe, easy hotstick
installation and removal from test point.
20-Year Neon Bulb Yields long, maintenance-free
service life.
Testable with V2-TB Easily tested for confirmation of
proper operation with the V2-TB voltage indicator test
box.
Cat. No. Description
V2 Voltage Indicator with Neon Display
V2-TB Voltage Indicator Test Box
V2-TB Test Box for easy field testing of V2 Voltage Indicators
If the V2 Neon Voltage Indicator indicates a power failure in an underground
distribution circuit, you’ll want to ensure that it’s actually the circuit that’s failed
and not the V2 itself. For fast, simple assurance, field test the V2 with the
compact, portable V2-TB Voltage Indicator Test Box, powered by replaceable C batteries.
Faulted Circuit Indicators
Test Point V2 Voltage Indicator (cont’d)
Elastimold®Cable Accessories
A58
w w w . t n b . c a
MVS Molded Vaccum Switches
Spring-energy, load-switching devices that make, carry and
interrupt load currents through 600 A on 5 to 38 kV
distribution systems.
MVS Molded Vacuum Switches include molded-in elbow connection
interfaces and spring-energy mechanisms. Available in both single- and
three-phase models, units are manually operated with a hotstick. Motor
operator, SCADA and auto-transfer control options are available.
EPDM Molded Rubber Insulation MVSs are fully sealed and submersible.
Vacuum Switching and Vacuum Interruption Components are
maintenance-free and require no gas or oil.
Compact and Lightweight Small footprint enables MVSs to fit
in tight padmount, subsurface, vault or riser pole installations.
Single-Phase Switches Approximate Weight: 30 lb.
12-1/2
(318)
4-1/16
(103)
5-1/2
(140)
6-7/16
(164)
6-15/64
(176)
6-15/64
(176)
12-1/2
(318)
5-1/2
(140)
6-1/16
(154)
13-7/16
(341)
43o
Open Closed
10-5/32
(258)
8-1/32
(204) 6-51/64
(173)
1-35/64 (39)
25-27/32
(656)
23-25/32
(604)
8-5/32
(207)
8-15/16
(227)
8-15/16
(227)
43o
Open Closed
13-7/16
(341)
(4) Mounting Holes, 5⁄8 in. Dia. x 7⁄8 in. (16 x 22 mm)
(4) Mounting Holes, 58 in. Dia. x 78 in. (16 x 22 mm)
Available with 600 A one-piece bushings or 200 A wells on either/both terminals.
Molded Vacuum Switches and Fault Interrupters
Underground
Distribution Switchgear
Elastimold®Cable Accessories
w w w . t n b . c a
Underground
Distribution Switchgear
Maximum Design Voltage (kV) 15.5 27 38
Frequency (Hz) 50/60 50/60 50/60
BIL Impulse (kV) 95 125 150
One-Minute AC Withstand (kV) 35 60 70
Fifteen-Minute DC Withstand (kV) 53 78 103
Load Interrupting & Loop Switching (Amp) 600 600 600
Transformer Magnetizing Interrupting (Amp) 21 21 21
Capacitor or Cable Charging Interrupting (Amp) 40 40 40
Asymmetrical Momentary and 3-Operation Fault Close (Amp) 20 20 20
Symmetrical One-Second Rating (Amp) 12,5 12,5 12,5
Continuous Current (Amp) 600 600 600
Eight-Hour Overload Current (Amp) 900 900 900
Ratings Application Information
Construction: Submersible, corrosion resistant, fully shielded
Ambient Temperature Range: -40°C to 65°C
Certified Tests
MVS loadbreak switches have been designed and tested per
applicable portions of IEEE, ANSI, NEMA and other industry
standards, including:
IEEE C37.74 Standard for Subsurface, Vault and Padmounted
Load-Interrupting Switches
IEEE 386 Standard for Separable Connectors and Bushing Interfaces
IEC 265 International Standards for Load-Interrupting Switches
ANSI C57.12.28 Standard for Padmount Enclosures
Closed
Position
Operating
Handle
Patented Silicone Rubber Diaphragm
Separates Line and Ground Potential
Cable Connection Bushings
Spring Operating Mechanism Contained
within 304 Stainless Steel Housing
Insulated Drive
Rod Assembly Molded EPDM Rubber
Insulation and Shielding
Molded Vacuum Switches and Fault Interrupters
Three-Phase Switches
Approximate Weight: 135 lb.
18-1⁄2 in.
(483 mm)
26 in.
(660 mm)
14 in.
(356 mm)
21 in.
(533 mm)
18 in.
(470 mm)
19 in.
(483 mm)
9-1⁄2 in.
(241 mm)
5-1⁄2 in.
(140 mm)
Available with 600 A one-piece bushings or 200 A wells on either/both terminals.
5-1⁄2 in.
(140 mm)
Vacuum Interrupter
Contact System
43o
Open
Position
A59
Elastimold®Cable Accessories
A60
w w w . t n b . c a
MVI Molded Vacuum Fault Interrupters
Underground
Distribution Switchgear
Make, carry and automatically interrupt currents through 25,000 A
symmetrical on 5 to 38 kV distribution systems
MVI Molded Vacuum Fault Interrupters include molded-in elbow connection interfaces
and tripfree mechanisms. They are available in single- and three-phase models. Units
are self-powered and include current-sensing and electronic control.
Underground
Distribution Switchgear
Combines Vacuum Interrupters, Programmable, Electronic,
Self-Powered Controls and EPDM Rubber Insulation
Components provide compact, lightweight and submersible overcurrent protection.
Field Programmable with a Wide Range of Time-Current
Characteristic (TCC) Curves and Trip Settings
TCC curves provide predictable tripping for ease of coordination with upstream
and/or downstream protective devices.
Control Monitors the Circuit Condition
When the programmed parameters are exceeded, a signal is sent to the tripping mechanism.
Motor Operators and Controls Available
Enable radial feeders or loops to be reconfigured, either manually or via SCADA.
200 A Wells
600 A Bushings
Front View Single-Phase
600 A T Elbow Interface
Conforms to
ANSI Std. 386
6-1⁄4 in.
(156 mm)
Ground
Lug
Programmable Control
& Current Transformer Open/ Reset
Closed/
Tripped
600 A Bushing
Interfaces
9-1⁄2 in.
(241 mm)
2-57⁄64 in.
(73 mm)
Well Interface Accepts
Standard Bushing Inserts
5-1⁄2 in.
(140 mm)
30-5⁄8 in.
(778 mm)
29-1⁄8 in.
(740 mm)
12-1⁄2 in.
(318 mm)
8-61⁄64 in.
(227 mm)
5-27⁄32 in.
(148 mm)
8-61⁄64 in.
(227 mm)
8-15⁄16 in.
(227 mm)
Front View Three-Phase
19 in..
(483 mm)
Mounting
32-7⁄8 in.
(156 mm)
18-1⁄2 in.
(470 mm)
Mounting
14-3⁄32 in.
(358 mm)
Mounting
17-45⁄64 in.
(277 mm)
10-57⁄64 in.
(277 mm)
5-1⁄2 in.
(140 mm)
Locking
Features
Alternate Handle Position;
Handle may be Repositioned in 60° Increments
5-1⁄2 in.
(140 mm)
600 Series
Elbow Interfaces
Elastimold®Cable Accessories
A61
w w w . t n b . c a
Voltage Class (kV) 15.5 15.5 15.5 27 35 35
Maximum Design Voltage (kV) 17 17 15.5 29 38 38
Frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60
BIL Impulse Withstand (kV) 95 95 95 125 150 150
One-Minute AC Withstand (kV) 35 35 35 60 70 70
Five-Minute DC Withstand (kV) 53 53 53 78 103 103
Continuous Current (A) 600 600 600 600 600 600
Load Interrupting and Loop Switching (A) 600 600 600 600 600 600
Transformer Magnetizing Interrupting (A) 21 21 21 21 21 21
Capacitor or Cable Charging Interrupting (A) 40 40 40 40 40 40
Symmetrical/Asymmetrical Interrupting Capability (kA) 12.5/20 16/25.6 20/32 12.5/20 12.5/20 25/40
Current Sensor Ratio 1,000:1 1,000:1 1,000:1 1,000:1 1,000:1 1,000:1
Ratings
Application Information
Meets ANSI C37.60 requirements
Ambient Temperature Range: -40°C to 65°C
Certified Tests
MVI Molded Vacuum Fault Interrupters have been designed and tested per applicable
portions of IEEE, ANSI, NEMA and other industry standards, including:
ANSI C37.60 Standard for Fault Interrupters
IEEE 386 Standard for Separable Connectors and Bushing Interfaces
ANSI C57.12.28 Standard for Padmounted Enclosures
Positive
Contact
Position
Operating Handle
Control Module (1-Phase)
Sensing Module (3-Phase)
Patented Silicone Rubber Diaphragm
Separates Line and Ground Potential
Cable Connection Bushings
Spring Operating
Mechanism
with Tripping
Insulated Drive
Rod Assembly
Molded EPDM Rubber
Insulation and Shielding Vacuum Fault Interrupter
Contact System
Underground
Distribution Switchgear
MVI Molded Vacuum Fault Interrupters
Elastimold®Cable Accessories
A62
w w w . t n b . c a
Internal Control
This control is integral to the unit (no separate control box). It is accessible via a compu-
ter connection to view or modify settings. This control is used on ganged three-phase or
single-phase MVI interrupters. Phase and ground trip, as well as inrush restraint, are
available. The E-Set software enables the user to connect to the internal control, either
in the shop or in the field, to program or change settings. An MVI-STP-USB program-
ming connector is required to connect between the PC and the MVI. With a computer
connected to the MVI control, the user can view real-time currents, the number of over-
current protection operations, current magnitude of the last trip and the phase/ground
fault targets. This is the standard control option.
External Control with Single-/Three-Phase Trip Selection
(Style 10 and 310)
This control is mounted externally to the mechanism and provides the ability to select
TCCs by setting DIP switches on the front panel. Each phase can be assigned a different
minimum trip setting by means of manual rotary switches. This control is used on one,
two or three single-phase MVI mechanisms.
External Control with Phase and Ground Trip (Style 20 and 320)
This control is mounted externally to the mechanism and provides the ability to select
phase minimum trip (one for all three phases), time delay for phase tripping, ground trip
as a percent of phase minimum trip and ground trip delay by means of manual rotary
switches. This control may be used on ganged three-phase or three single-phase MVI
mechanisms.
NOTE: E-Set can be downloaded from www.elastimoldswitchgear.com
Choose from five electronic control options to interrupt faults
Molded Vacuum Interrupters are provided with self-powered electronic control packages requiring no batteries or external power. Depending on
the application, five electronic control options are available for the MVI — see below and on following page.
Molded Vacuum Switches and Fault Interrupters
Underground
Distribution Switchgear
Include Self-Powered Electronic Control Packages No batteries or external power are required. Controls send a signal to the vacuum interrupters to trip open
and interrupt the fault when an
overcurrent condition is detected.
Field-Selectable Fuse or Relay Curves and Trip Settings One device for many protection schemes.
Elastimold®Cable Accessories
A63
w w w . t n b . c a
Underground
Distribution Switchgear
Molded Vacuum Switches and Fault Interrupters
External Control with Three-Phase Trip Only (Style 30 and 330)
This control is mounted externally to the mechanism and provides the ability to select
phase minimum trip (one for all three phases) by means of a manual rotary switch. It
also has an RS-232 port for connection to a PC to view the last trip data. This control is
used on ganged three-phase or three single-phase MVI mechanisms.
External Control with Selectable Single-/Three-Phase
Trip Function (80 and 380 Control)
This control is mounted externally to the mechanism of the interrupter and provides the
ability to select between a single-phase trip and a three-phase trip. The 80 and 380
Control can be used with one three-phase interrupter or with three single-phase inter-
rupters. For three-phase applications, the ground trip function can be blocked from the
front panel. Manual trip and reset target buttons are also located on the front panel. This
control uses the E-Set software, which enables programming via a computer using the
MVI-STP-USB adapter. E-Set features custom TCC curves and provides access to the
last fault event information, as well as real-time current per phase.
Curve
Reference No. Curve No. Curve Type
Relay Curves (minimum trip 30–600A)
MVI-TCC-01 1 E Slow
MVI-TCC-02 2 E Standard
MVI-TCC-03 3 Oil Fuse Cutout
MVI-TCC-04 4 K
MVI-TCC-05 5 Kearney QA
MVI-TCC-06 6 Cooper EF
MVI-TCC-07 7 Cooper NX-C
MVI-TCC-08 8 CO-11-1
MVI-TCC-09 9 CO-11-2
MVI-TCC-10 10 T
MVI-TCC-11 11 CO-9-1
MVI-TCC-12 12 CO-9-2
MVI-TCC-13 13 Cooper 280ARX
MVI-TCC-14 14 F
MVI-TCC-16 16 Kearney KS
MVI-TCC-17 17 GE Relay
MVI-TCC-18–23 18–23 CO-8-1–CO-8-6
MVI-TCC-24–27 24–27 CO-9-3–CO-9-6
MVI-TCC-28–31 28–31 CO-11-3–CO-11-6
Curve
Reference No. Curve No. Curve Type
Fuse Curves (minimum trip 10–200A)
MVI-TCC-54 54 E Slow
MVI-TCC-55 55 E Standard
MVI-TCC-56 56 Oil Fuse Cutout
MVI-TCC-57 57 K
MVI-TCC-58 58 Kearney QA
MVI-TCC-59 59 Cooper NX-C
MVI-TCC-60 60 T
Elastimold®Cable Accessories
A64
w w w . t n b . c a
The following diagram shows how to construct a catalogue number for Molded Vacuum Switches and Interrupters. Catalogue numbers are
shown below.
EXAMPLE: The catalogue number for a Molded Vacuum Interrupter on a three-phase, 27 kV system, with 600 A terminal and parking stands
between bushings is MVI3-21-27-66-PS.
Indicates field that must
be filled in to complete order.
Note: Availability of selected configuration will be verified at quotation time.
Switch Type
RRiser Pole
NNetwork
Blank Subsurface
Device
SSwitch
IInterrupter
M V SUFFIX
End Interface
2200 A Bushing Well
6600 A Bushing
2 1
Phases
1Single-Phase
3Three-Phase
Voltage Class
15 15.0 kV
27 27.0 kV
38 38.0 kV
Interface
E600 A T Body
REnd Interface Rotated 180°
AB Air Bushings (for Riser Pole)
Main Interface
2200 A Bushing Well
6600 A Bushing
Cat. No. Suffix Description
20 External 20 Control with Phase and Ground Trip (to be used on ganged three-phase MVI mechanism)
30 External 30 Control with Three-Phase Trip Only (to be used on ganged three-phase MVI mechanism)
80 External 80 Control with Selectable Single-/Three-Phase Trip Function (to be used on ganged three-phase MVI mechanism)
110 External 10 Control with Single Trip Selection (to be used on one single-phase MVI mechanism)
310 External 10 Control with Single-/Three-Phase Trip Selection (to be used on three single-phase MVI mechanisms)
320 External 20 Control with Phase and Ground Trip (to be used on three single-phase MVI mechanisms)
330 External 30 Control with Three-Phase Trip Only (to be used on three single-phase MVI mechanisms)
380 External 80 Control with Selectable Single-/Three-Phase Trip Function (to be used on three single-phase mechanisms
MO120A 120VAC Motor Operator and Controller for MVS3 or MVI3 Units
MO12D 12–24VDC Motor Operator and Controller for MVS3 or MVI3 Units
PS Parking Stand for MVS or MVI (between bushings for single- or three-phase units)
MPS Parking Stand for MVS3, MVI3 or RMVI3 on Mechanism Cover
PS6 Double Parking Stand for MVS3, MVI3 or RMVI3 (between bushings and on mechanism cover)
BT Bail Tab Plate Installed for Three-Phase Units Only
PCustomer Settings to be Programmed at the Factory
Leave suffix blank for internal (self-contained) control.
Controls and Accessories
Cat. No. Description Width in. (mm) Height in. (mm) Depth in. (mm) Weight lb. (kg) Diagram
Single-Phase Vacuum Switches
MVS1-21-15-XX 15 kV 2-Way 1-Phase Switch
6 (152) 24 (610)
14 (356)
30 (14)
MVS1-21-15-6EX 15 kV 2-Way 1-Phase Switch — Elbow Interface 15 (381)
MVS1-21-27-XX 25 kV 2-Way 1-Phase Switch 14 (356)
MVS1-21-27-6EX 25 kV 2-Way 1-Phase Switch — Elbow Interface 15 (381)
MVS1-21-38-XX 35 kV 2-Way 1-Phase Switch 14 (356)
Three-Phase Vacuum Switches
MVS3-21-15-XX 15 kV 2-Way 3-Phase Switch
21 (533) 26 (660) 19 (483) 135 (61)
MVS3-21-27-XX 25 kV 2-Way 3-Phase Switch
MVS3-21-38-XX 35 kV 2-Way 3-Phase Switch
MVS Molded Vacuum Switches
* Height includes handle. ** 3-Phase Vacuum Switches are motor-ready.
*
*
**
Underground Distribution Switchgear
Molded Vacuum Switches and Fault Interrupters
Elastimold®Cable Accessories
A65
w w w . t n b . c a
Underground Distribution Switchgear
MVI Molded Vacuum Interrupters***
Cat. No. Description Width
in. (mm)
Height
in. (mm)
Depth
in. (mm)
Weight
lb. (kg) Diagram
Riser Pole (Three-Phase Installations Only)
RMVI3-21-15-6ABX-YY 15kV 2-Way 3-Phase Interrupter with Air Bushings on Top Terminals 30 (762) 45 (1,143) 25 (635) 150 (68)
RMVI3-21-27-6ABX-YY 25kV 2-Way 3-Phase Interrupter with Air Bushings on Top Terminals 30 (762) 45 (1,143) 25 (635) 150 (68)
RMVI3-21-38-6ABX-YY 38kV 2-Way 3-Phase Interrupter with Air Bushings on Top Terminals 30 (762) 45 (1,143) 25 (635) 150 (68)
RMVI1-21-15-6ABX-3YY 15kV 2-Way 3-Phase Interrupter with Air Bushings on Top Terminals, 1-Phase Trip Selectable 30 (762) 45 (1,143) 25 (635) 150 (68)
RMVI1-21-27-6ABX-3YY 27kV 2-Way 3-Phase Interrupter with Air Bushings on Top Terminals, 1-Phase Trip Selectable 30 (762) 45 (1,143) 25 (635) 150 (68)
RMVI1-21-38-6ABX-3YY 38kV 2-Way 3-Phase Interrupter with Air Bushings on Top Terminals, 1-Phase Trip Selectable 30 (762) 45 (1,143) 25 (635) 150 (68)
Subsurface Single-Phase Vacuum Switches
MVI1-21-15-XX 15kV 2-Way 1-Phase Interrupter 6 (152) 31 (787) 9 (229) 45 (20)
MVI1-21-15-6EX 15kV 2-Way 1-Phase Interrupter, Elbow Interface 6 (152) 31 (787) 11 (279) 45 (20)
MVI1-21-27-XX 27kV 2-Way 1-Phase Interrupter 6 (152) 31 (787) 9 (229) 45 (20)
MVI1-21-27-6EX 27kV 2-Way 1-Phase Interrupter, Elbow Interface 6 (152) 31 (787) 11 (279) 45 (20)
MVI1-21-38-XX 38kV 2-Way 1-Phase Interrupter 6 (152) 31 (787) 9 (229) 45 (20)
MVI1-21-38-6EX 38kV 2-Way 1-Phase Interrupter, Elbow Interface 6 (152) 31 (787) 11 (279) 45 (20)
Subsurface Three-Phase Vacuum Switches
MVI1-21-15-XX-3YY 15kV 2-Way 3-Phase Interrupter, 1-Phase Trip Selectable Ext. Control 20 (508) 31 (787) 9 (229) 145 (66)
MVI1-21-27-XX-3YY 27kV 2-Way 3-Phase Interrupter, 1-Phase Trip Selectable Ext. Control 20 (508) 31 (787) 9 (229) 145 (66)
MVI1-21-38-XX-3YY 38kV 2-Way 3-Phase Interrupter, 1-Phase Trip Selectable Ext. Control 20 (508) 31 (787) 9 (229) 145 (66)
MVI3-21-15-XX-YY 15kV 2-Way 3-Phase Interrupter 20 (508) 33 (838) 10 (254) 145 (66)
MVI3-21-27-XX-YY 27kV 2-Way 3-Phase Interrupter 20 (508) 33 (838) 10 (254) 145 (66)
MVI3-21-38-XX-YY 38kV 2-Way 3-Phase Interrupter 20 (508) 33 (838) 10 (254) 145 (66)
***Air bushings on top terminal.
Cat. No. Description
MVI-STP-USB Adapter for Connection between MVI Units with Internal Control and a Computer for Programming/Viewing Settings
MV1PMB Pole-Mounting Bracket for 1-Phase Units Only
MV3PMB Pole-Mounting Bracket for 3-Phase Units Only
MV3HPMB Horizontal Pole-Mounting Bracket for 3-Phase Units Only
MV13PMB Pole-Mounting Bracket for Three 1-Phase Units Only
35AL-11 Connector Bare Wire Type 3⁄4"–16 Rod for Riser Pole Units Qty. of 1 Needed per Phase
35AL-12 Connector 2-Hole Spade Type 3⁄4"–16 Rod for Riser Pole Units Qty. of 1 Needed per Phase
MVI-TESTER Tester for Electric Control Style 80
Accessories (order separately)
Weights and dimensions are approximate.
X = 6 for 600A or 2 for 200A or 6E for 600A T interface.
Y = 10, 20, 30, 80 for different electronic controls.
Leave blank for internal (self-contained) control.
Accessories should be added as suffix to the main catalog number unless otherwise noted.
Other configurations are available. Please consult your local representative on configurations not shown here.
The 3-Phase Vacuum Interrupters are motor-ready.
Elastimold®Cable Accessories
A66
w w w . t n b . c a
Multi-way vault and padmount units are built using MVS, MVI and MCAN modules as required by
the application. These are mounted onto the ES multi-way common bus system and assembled
on a free-standing, floor-mounted frame. At this stage, the product is ready to be used in vault
installations.
For padmount installations, a double-sided, drop-over, painted, mild steel enclosure is provided.
Munsell Green 7GY 3.29/1.5 is the standard enclosure color. Other colors are available upon re-
quest. Painted stainless steel or fiberglass enclosures are available as options.
Multi-Way Unit Construction
Vault-Style UnitCommon Bus Assembly
Top Lifts Up for Ease
of Operation
Internal Electronic Control
and Current-Sensing
Device (3-Phase MVI and
External Controls also
available)
200A Wells (shown);
600A Bushings available
MVI Mechanism on
1-Phase Protection Tap
(3-Phase also available)
Ground Rod
Parking Stand
Padmount Unit: Tap (Load) Side
* Also available with a fiberglass enclosure.
Mild or Stainless Steel
Enclosures available*
Internal Electronic Control
and Current-Sensing
Device (3-Phase MVI
and External Controls
also available)
Underground Distribution Switchgear
Multi-Way Switchgear and Transfer Packages
Elastimold®Cable Accessories
A67
w w w . t n b . c a
Underground Distribution Switchgear
Multi-Way Switchgear and Transfer Packages
The following diagram shows how to construct a catalogue number for Multi-Way Switchgear or Transfer Packages. Catalogue number are
shown on page A61 for the most common configurations.
EXAMPLE: The catalogue number for an auto-transfer package for padmount installation on a 3-phase, 27 kV system, with two MVI protected
taps, 600 A terminals and standard mild steel enclosure is ATD324-AAPP-6666.
Switch Type
AT
Auto Transfer
ES
Multi-Way Switch
Custom padmount enclosure dimensions are available.
Parking stands are standard on padmount units.
Consult your Regional Sales Office on multi-way configurations that include 38kV MVIs.
3-Phase MVS and MVI are motor-ready.
Auto-transfer ways 1 and 2 are always “A.”
Type
V
Vault
S
Subsurface
D
Double-Side Padmount
P
Single-Side Padmount
Phases
1
1-Phase
3
3-Phase
Voltage Class
1
15.0 kV
2
27.0 kV
3
38.0 kV
Number of Ways
2
2-Way
3
3-Way
4
4-Way
Components by Way
A
3-Phase Switch Motor Operator Auto Transfer
B
Solid Tap/Direct Bus Connection (600 A or 200 A)
C
3-Phase MVI Fault Interrupter, 20 Control
D
3-Phase MVI Fault Interrupter, 30 Control
J
1-Phase Fault Interrupter
K
1-Phase Fault Interrupter, 10 Control
L
1-Phase Fault Interrupter, 80 Control
M
1-Phase Fault Interrupter, 20 Control
N
1-Phase Fault Interrupter, 30 Control
O
3-Phase MVI Fault Interrupter, 80 Control
P
3-Phase MVI Fault Interrupter
Q
3-Phase MVS Switch with UAD Control
R
3-Phase MVI Fault Interrupter Motor Operator, 1224VDC
S
1-Phase MVS Switch
T
3-Phase MVS Switch
U
3-Phase MVS with 1224VDC Motor
V
3-Phase MVS with 120VAC Motor
W
3-Phase MVI Fault Interrupter Motor Operator, 120VAC
Z
3-Phase MVI Fault Interrupter with UAD Control
Enclosure Material
Blank
Mild Steel
S
Stainless Steel
Cabinet Depth
Padmount
Blank
54 in.
Interface by Way
2
200 A Bushing Well
6
600 A Bushing
Example: ATD324-AAPP-6666
Way 1
Way 3
Way 2
Way 4
A
P
A
P
Single-Side Padmount ESP313-BJB-626
Subsurface ESS3X2-TT-66MSV3 Switch
Stainless Steel Bottom Rails
5-1⁄2 in.
(140 mm)
84 in.
(2,134 mm)
42 in.
(1,067 mm) 54 in.
(1,372 mm)
54 in.
(1,372 mm)
33-18 in.
(841 mm)
19 in.
(483 mm)
35-38 in.
(899 mm)
48 in.
(1,219 mm)
Vault ESV3X4-TTTT-2222
Cable Accessories
A68
w w w . t n b . c a
Elastimold®
Underground Distribution Switchgear
Multi-Way Switchgear and Transfer Packages
X = 6 for 600A or 2 for 200A.Other configurations are available. Consult your local representative for configurations not shown here.
Cat. No. Description Width in. (mm Height in. (mm) Depth in. (mm) Weight lb. (kg) Diagram
Vault
ESV313-TTT-XXX 15kV 3-Way 3-Phase Switch 48 (1,219) 36 (914) 22 (559) 750 (340)
ESV323-TTT-XXX 27kV 3-Way 3-Phase Switch 48 (1,219) 36 (914) 22 (559) 750 (340)
ESV333-TTT-XXX 38kV 3-Way 3-Phase Switch 48 (1,219) 36 (914) 22 (559) 750 (340)
ESV314-TTTT-XXXX 15kV 4-Way 3-Phase Switch 48 (1,219) 36 (914) 22 (559) 880 (399)
ESV324-TTTT-XXXX 27kV 4-Way 3-Phase Switch 48 (1,219) 36 (914) 22 (559) 880 (399)
ESV334-TTTT-XXXX 38kV 4-Way 3-Phase Switch 48 (1,219) 36 (914) 22 (559) 880 (399)
Padmount
PMVS1-21-15-XX 15kV 2-Way 3-Phase Switch 36 (914) 30 (762) 30 (762) 310 (141)
PMVS1-21-27-XX 27kV 2-Way 3-Phase Switch 36 (914) 30 (762) 30 (762) 310 (141)
PMVS1-21-38-XX 38kV 2-Way 3-Phase Switch 36 (914) 30 (762) 30 (762) 310 (141)
ESD312-T-XX 15kV 2-Way 3-Phase Switch 36 (914) 48 (1,219) 42 (1,067) 680 (308)
ESD322-T-XX 27kV 2-Way 3-Phase Switch 36 (914) 48 (1,219) 42 (1,067) 680 (308)
ESD332-T-XX 38kV 2-Way 3-Phase Switch 36 (914) 48 (1,219) 42 (1,067) 680 (308)
ESD313-TTT-XXX 15kV 3-Way 3-Phase Switch 54 (1,317) 48 (1,219) 54 (1,317) 1,250 (567)
ESD323-TTT-XXX 27kV 3-Way 3-Phase Switch 54 (1,317) 48 (1,219) 54 (1,317) 1,250 (567)
ESD333-TTT-XXX 38kV 3-Way 3-Phase Switch 54 (1,317) 48 (1,219) 54 (1,317) 1,250 (567)
ESD314-TTTT-XXXX 15kV 4-Way 3-Phase Switch 54 (1,317) 48 (1,219) 54 (1,317) 1,380 (626)
ESD324-TTTT-XXXX 27kV 4-Way 3-Phase Switch 54 (1,317) 48 (1,219) 54 (1,317) 1,380 (626)
ESD334-TTTT-XXXX 38kV 4-Way 3-Phase Switch 54 (1,317) 48 (1,219) 54 (1,317) 1,380 (626)
Double-Side Padmount ESD3X4-IIPP-6622-S
Switching and Sectionalizing Switchgear
Cable Accessories
A69
w w w . t n b . c a
Elastimold®
Multi-Way Switchgear and Transfer Packages
Cat. No. Description Width in. (mm) Height in. (mm) Depth in. (mm) Weight lb. (kg) Diagram
Vault
ESV313-TPP-XXX 15 kV 3-Way 3-Phase (1) Source Switch, (2) Vacuum Interrupter Taps
40 (1,016) 48 (1,219) 22 (559)
660 (299)
ESV323-TPP-XXX 27 kV 3-Way 3-Phase (1) Source Switch, (2) Vacuum Interrupter Taps
ESV313-TTP-XXX 15 kV 3-Way 3-Phase (2) Source Switches, (1) Vacuum Interrupter Tap
ESV323-TTP-XXX 27 kV 3-Way 3-Phase (2) Source Switches, (1) Vacuum Interrupter Tap
ESV314-TPPP-XXXX 15 kV 4-Way 3-Phase (1) Source Switch, (3) Vacuum Interrupter Taps
880 (399)
ESV324-TPPP-XXXX 27 kV 4-Way 3-Phase (1) Source Switch, (3) Vacuum Interrupter Taps
ESV314-TTPP-XXXX 15 kV 4-Way 3-Phase (2) Source Switches, (2) Vacuum Interrupter Taps
ESV324-TTPP-XXXX 27 kV 4-Way 3-Phase (2) Source Switches, (2) Vacuum Interrupter Taps
ESV314-TTTP-XXXX 15 kV 4-way 3-Phase (3) Source Switches, (1) Vacuum Interrupter Tap
ESV324-TTTP-XXXX 27 kV 4-Way 3-Phase (3) Source Switches, (1) Vacuum Interrupter Tap
Padmount
PMVI1-21-15-XX 15 kV 2-Way 1-Phase Interrupter
36 (914) 30 (762)
30 (762)
310 (141)
PMVI1-21-27-XX 27 kV 2-Way 1-Phase Interrupter
PMVI1-21-38-XX 38 kV 2-Way 1-Phase Interrupter
PMVI1-21-15-XX-3YY 15 kV 2-Way 3-Phase Interrupter 1-Phase Trip Selectable Ext. Control
48 (1,219) 42 (1,067)
680 (308)
PMVI1-21-27-XX-3YY 27 kV 2-Way 3-Phase Interrupter 1-Phase Trip Selectable Ext. Control
PMVI1-21-38-XX-3YY 38 kV 2-Way 3-Phase Interrupter 1-Phase Trip Selectable Ext. Control
ESD312-P-XX 15 kV 2-Way 3-Phase (1) Vacuum Interrupter Tap
36 (914)
48 (1,219)
42 (1,067)
ESD322-P-XX 27 kV 2-Way 3-Phase (1) Vacuum Interrupter Tap
ESD332-P-XX 38 kV 2-Way 3-Phase (1) Vacuum Interrupter Tap
ESD313-TPP-XXX 15 kV 3-Way 3-Phase (1) Source Switch, (2) Vacuum Interrupter Taps
54 (1,372) 54 (1,372) 1,160 (526)
ESD323-TPP-XXX 27 kV 3-Way 3-Phase (1) Source Switch, (2) Vacuum Interrupter Taps
ESD333-TPP-XXX 38 kV 3-Way 3-Phase (1) Source Switch, (2) Vacuum Interrupter Taps 72 (1,829) 54 (1,372) 72 (1,829) 1,500 (680)
ESD313-TTP-XXX 15 kV 3-Way 3-Phase (2) Source Switches, (1) Vacuum Interrupter Tap
54 (1,372) 48 (1,219) 54 (1,372) 1,160 (526)
ESD323-TTP-XXX 27 kV 3-Way 3-Phase (2) Source Switches, (1) Vacuum Interrupter Tap
ESD333-TTP-XXX 38 kV 3-Way 3-Phase (2) Source Switches, (1) Vacuum Interrupter Tap 72 (1,829) 54 (1,372) 72 (1,829) 1,500 (680)
ESD314-TPPP-XXXX 15 kV 4-Way 3-Phase (1) Source Switch, (3) Vacuum Interrupter Taps
54 (1,372) 48 (1,219) 54 (1,372) 1,380 (626)
ESD324-TPPP-XXXX 27 kV 4-Way 3-Phase (1) Source Switch, (3) Vacuum Interrupter Taps
ESD334-TPPP-XXXX 38 kV 4-Way 3-Phase (1) Source Switch, (3) Vacuum Interrupter Taps 72 (1,829) 54 (1,372) 72 (1,829) 1,500 (680)
ESD314-TTPP-XXXX 15 kV 4-Way 3-Phase (2) Source Switches, (2) Vacuum Interrupter Taps
54 (1,372) 48 (1,219) 54 (1,372) 1,380 (626)
ESD324-TTPP-XXXX 27 kV 4-Way 3-Phase (2) Source Switches, (2) Vacuum Interrupter Taps
ESD334-TTPP-XXXX 38 kV 4-Way 3-Phase (2) Source Switches, (2) Vacuum Interrupter Taps 72 (1,829) 54 (1,372) 72 (1,829) 1,500 (680)
ESD314-TTTP-XXXX 15 kV 4-Way 3-Phase (3) Source Switches, (1) Vacuum Interrupter Tap
54 (1,372) 48 (1,219) 54 (1,372) 1,380 (626)
ESD324-TTTP-XXXX 27 kV 4-Way 3-Phase (3) Source Switches, (1) Vacuum Interrupter Tap
ESD334-TTTP-XXXX 38 kV 4-Way 3-Phase (3) Source Switches, (1) Vacuum Interrupter Tap 72 (1,829) 54 (1,372) 72 (1,829) 1,500 (680)
X = 6 for 600 A or 2 for 200 A.
YY = 10, 20, 30, 80 for different electronic controls.
Consult your Regional Sales Office on 38 kV multi-way configurations.
Underground Distribution Switchgear
Overcurrent Protection Switchgear
Cable Accessories
A70
w w w . t n b . c a
Elastimold®
Molded Fuse Products
The fastest, most cost-effective way to improve a distribution
system’s reliability
Fused Elbows
Replace existing 200 A tap elbows with Elastimold®Fused Elbows to protect
light-duty underground distribution systems, including sub-loops, radial taps, junctions,
transformers and other equipment.
Elastimold®Fused Elbows provide full-range current-limiting fusing with 50 kA interrupting
capability. They are rated for 5 kV ungrounded to 28 kV grounded Wye. Plus they provide
15/25 kV hotstick-operable, loadbreak elbow switching.
Combined Full-Range Current-Limiting Fusing 15/25 kV Hotstick-Operable, Loadbreak Elbow Switching Quickly improve the distribution
system’s reliability without the expense of adding a separate piece of switchgear or replacing existing sectionalizing cabinets.
High Fault Close Rating Current-limiting fuses improve the fault close rating of the elbow (10 kA) to that of the fuse, thereby reducing the risk
of component damage or personnel injury.
EPDM Molded Rubber Deadfront Construction Elbows are fully sealed and submersible, and they insulate, shield and eliminate exposed live parts.
Two-Piece Housing Enables easy fuse replacement.
Application Information
Construction: Submersible, non-venting, deadfront,
corrosion resistant
Ambient Temperature Range: -30°C to 65°C
Certified Tests
Elastimold®Fused Elbows have been designed and tested per
applicable portions of IEEE, ANSI and other industry standards,
including:
ANSI C37.40 Standard for Current-Limiting Fuse Service Conditions
ANSI C37.41 Standard for Current-Limiting Fuse Design and Testing
ANSI C37.47 Standard for Current-Limiting Fuse Ratings
and Specifications
IEEE 386 Standard for Separable Connectors
Ratings
System Voltage Class (kV) 15 25* 25/28*
Nominal Fuse Voltage (kV) 8.3 15.5 17.2
Rated Maximum Fuse Voltage (kV) 8.8/10 15.5 17.2
Frequency (Hz) 50/60 50/60 50/60
BIL Impulse Withstand (kV) 95 125 140
One-Minute AC Withstand (kV) 34 40 45
Fifteen-Minute DC Withstand (kV) 53 78 78
Corona Extinction (kV) 11 19 21.5
Symmetrical Interrupting Capability (Amp) 50,000 50,000 50,000
Current Rating (Amp) 3–80 6–20 3–45
* The 15.5 kV L-G rated fuse requires 75% grounded load to be applied on a 25 kV system.
The 17.2 kV L-G rated fuse requires at least 75% grounded load to be applied on a 28 kV system.
Fuses are only suitable for the system voltage class shown if the recovery voltage across the fuse
will not exceed its rated maximum voltage. For three-phase applications, this generally requires that
protected transformers be gndY–gndY and have at least 50% grounded load. Fuse replacement requires
the elbow to be de-energized.
Lower Elbow
Half
Hose Clamp
Crimp Lug
Fuse
Probe Lug
Upper Elbow
Half
Probe
Cable Accessories
A71
w w w . t n b . c a
Elastimold®
Molded Fuse Products
Fused Elbows
1. Designs have a 50,000 A RMS Symmetrical Rating (except 3 A, 17.2 kV — which was tested at 44 kA maximum).
2. Fuses have a Rated Maximum Application Temperature (RMAT) of 65º C. RMAT is the maximum temperature of the air, in contact with the elbow housing,
at which fuses have been shown to be suitable for use.
3. Tabulated Maximum Total I2t values are for currents of 50,000 A at the nominal voltage of the fuse. Values for 8.3kV fuses at 10kV are approximately 30% higher.
Values for 17.2 kV fuses at 15.5 kV are approximately 20% lower.
4. Maximum total I2t values are reduced for currents below 50,000A. For example, at 10,000A, maximum total I2t values are approximately 15% less than the published values.
5. Peak arc voltages listed are for 50,000A currents at the rated maximum voltage listed. Reduced currents and voltages will reduce the peak arc voltage. For more information, contact your T&B Regional Sales Office.
6. Maximum continuous currents at ambient temperatures other than those listed may be determined by derating the fuses by 0.2% per degree C over 25ºC. For example:
At 40ºC the derating would be 15 x 0.2 = 3%, making the maximum continuous current of a 17.2kV, 25A fuse 31.5 x 0.97 = 30.5 A.
7. Time-current characteristic curves are published at 25ºC. Reduction in the long time melting current of the fuses (approximately one hour and longer) due to higher ambient
temperatures is the same as described above for “maximum continuous currents.”
System Voltage
Class (kV)
Nominal Fuse
Voltage Rating (kV)
Current
Rating
(A)
Cat. No. Rated Max.
Voltage (kV)
Maximum Continuous
Current (2) (6) Peak Arc
Minimum
(kV)
Total l2t
Melt l2t
(A2-Sec)
Maximum
(A2-Sec)
(3) (4)
25ºC 40ºC 65ºC
15 8.3
3EFX083003-E
10.0
4.3 4.2 3.9 30 100 350
6EFX083006-E 9.5 9.0 8.5 32 620 2,7
8EFX083008-E 11.5 11.0 10.5 28 800 4
10 EFX083010-E 14.0 13.5 13.0 28 800 4
12 EFX083012-E 19.0 18.5 17.5 26 920 8
18 EFX083018-E 21.0 20 19.0 26 1,31 9,5
20 EFX083020-E 26.0 25 24.0 26 1,62 11
25 EFX083025-E 34.0 33.0 31.0 26 3,66 22
30 EFX083030-E 37.5 36.5 34.5 26 5,25 30
40 EFX083040-E 43.0 42.0 40.0 26 8,7 50
45 EFX083045-E 49.0 47.0 45.0 26 12,8 70
65 EFX083065-E 8.8 70.0 68.0 64.5 23 34 200
80 EFX083080-E 80.0 77.5 73.5 22 51,2 280
25 15.5
6EFX155006-E
15.5
8.5 8.0 7.7 52 620 3
8EFX155008-E 10.5 10.0 9.5 40 800 4,3
10 EFX155010-E 13.0 12.5 12.0 40 800 4,3
12 EFX155012-E 16.0 15.5 15.0 38 920 8
18 EFX155018-E 20.0 19.5 18.5 38 1,62 13
20 EFX155020-E 23.5 22.5 21.5 38 2,2 16,5
25/28 17.2
3EFX172003-E
17.2
4.3 4.2 3.9 51 100 510
6EFX172006-E 9.5 9.0 8.5 54 620 3,25
8EFX172008-E 11.5 11.0 10.5 46 800 4,6
10 EFX172010-E 14.0 13.5 13.0 46 800 4,6
12 EFX172012-E 18.0 17.5 16.5 43 920 8,5
18 EFX172018-E 20.0 19.5 18.5 45 1,31 10
20 EFX172020-E 24.0 23.0 22.0 45 1,62 12,5
25 EFX172025-E 31.5 30.5 29.0 45 3,66 27,5
30 EFX172030-E 35.5 34.5 32.5 45 5,25 37,5
40 EFX172040-E 41.0 40.0 38.0 45 8,7 62,5
45 EFX172045-E 46.0 45.0 42.5 45 12,8 87,5
Electrical Characteristics of Elastimold®EFX-E Elbow Fuses
Cable Accessories
A72
w w w . t n b . c a
Elastimold®
Molded Fuse Products
Fused Elbows
1. Column A = 140–200% of transformer rating and Column B = 200–300% of transformer rating.
2. Ratings in parenthesis are 17.2 kV fuses.
3. 8.3 kV, 3–45 A fuses and 15.5 kV, 6–20A fuses are used in the small (size 1) elbow housing; 8.3 kV, 65–80 A fuses and 17.2 kV, 3–45 A fuses are used in the large (size 3) elbow fuse housing.
4. Recommended fuses meet inrush criteria of 12 times transformer full-load current for 0.1 second and 25 times transformer full-load current for 0.01 second.
Fuses also meet cold-load pickup criteria of 6 times transformer full-load current for 1 second and 3 times transformer full-load current for 10 seconds.
a. Fuse allows greater than 300% of transformer rating.
Recommended Elastimold®EFX-E Elbow Fuse at 40ºC Ambient Temperature
Recommended Fuse Current Ratings (Amperes)
Fuse Voltage 8.3 kV 15.5 kV (17.2 kV)
1-Phase
Transformer
kVA
Transformer 1-Phase Voltage Rating (kV), Phase to Ground
2.4 4.16 4.8 7.2 7.62 12 14.4 16
ABABABABABABABAB
10 — 6 — 6a — 3 — 3 — 3 — 6a 6a (3a)
15 10 — 6 — 6a — 3 — 3 — 6a 6a (3a)
25 12 20 — 8 — 8 — 6 — 6 — 6a 6a -3
37.5 20 25 — 12 — 12 — 8 6 6 6a — (6a)
50 25 40 18 20 12 20 10 12 — 10 — 6 6 (6a)
75 45 65 20 30 20 25 12 20 12 18 — 10 — 8 -8
100 65 80 30 45 25 40 18 25 18 25 12 18 10 12 — -10
167 — 65 80 45 65 25 45 25 45 18 -25 18 20 -12 -20
250 — — 80 — 80 — 45 65 45 65 -25 -45 20 -30 -20 -30
333 — — — — — — 65 — 80 — -40 -30 -45 -25 -45
500 — — — — — — — — — — — — -45 -45
Recommended Elastimold®EFX-E Elbow Fuse at 40ºC Ambient Temperature
Recommended Fuse Current Ratings (Amperes)
Fuse Voltage 8.3 kV 15.5 kV (17.2 kV)
1-Phase
Transformer
kVA
Transformer 1-Phase Voltage Rating (kV), Phase to Ground
2.4 4.16 4.8 7.2–7.96 8.32 12.47 13.2–14.4 20.8 22.9–24.9
ABABABABABABABABAB
15 — 6 — 3 — 3 — 3a3a6a6a6a(3a)
22.5 8 6a6a— 3 — 3 — 6a6a6a(3a)
30 10 12 — 6 — 6 — 6a 3 6a6a6a(3a)
45 12 20 10 — 8 — 6 — 6a6a6a6a(3a)
75 20 30 12 20 12 — 8 — 8 — 6 — 6 — 6a— -3
100 30 45 18 25 18 20 — 12 — 10 — 8 8 6a(6a)
112.5 40 65 20 25 18 25 12 12 — 8 — 8 — 6 — (6a)
150 45 80 25 40 20 30 18 20 12 20 10 12 10 12 — 6 -6
200 65 80 40 65 30 45 20 25 18 25 12 18 12 18 8 10 — -8
225 80 — 45 65 40 65 20 30 20 25 12 20 12 18 8 10 — -10
300 — — 65 80 45 80 30 45 25 40 18 25 18 25 12 18 — -12
500 — — — 80 — 65 80 45 80 30 45 30 45 18 -25 -18 -25
750 — — — — — — 80 — 80 — 45 65 45 — -25 -45 -25 -40
1 — — — — — — — — — — 80 — — — -40 -40
Cable Accessories
A73
w w w . t n b . c a
Elastimold®
Molded Fuse Products
Full-Range Molded Current-Limiting Fuses
The following diagram shows how to construct a catalogue number for Fuse Housings and Full-Range Current-Limiting Fuses.
Indicates field that must be filled in to complete order.
Voltage Rating
083 8.3 kV
155 15.5 kV
172 17.2 kV
Amperage Rating
003 8.3/17.2 kV 3 A
006 8.3/15.5/17.2 kV 6 A
008 8.3/15.5/17.2 kV 8 A
010 8.3/15.5/17.2 kV 10 A
012 8.3/15.5/17.2 kV 12 A
018 8.3/15.5/17.2 kV 18 A
020 8.3/15.5/17.2 kV 20 A
025 8.3/17.2 kV 25 A
030 8.3/17.2 kV 30 A
040 8.3/17.2 kV 40 A
045 8.3/17.2 kV 45 A
065 8.3 kV 65 A
080 8.3 kV 80 A
EFX E
8.3 kV (3–45 A)/15.5 kV (6–20 A) Fuse
8.3 kV (65–80 A)/17.2 kV (3–45 A) Fuse
All dimensions rounded up to the nearest eighth inch.
13-1/2 in.
(343 mm)
9-1/4 in.
(235 mm)
2-1/4 in.
(54 mm)
2-1/4 in.
(54 mm)
Indicates field that must be filled in to complete order.
Nominal Fuse
Voltage Rating
168 8.3 kV
274 15.5 kV
274 17.2 kV
Conductor Size
180 6 –
190 – 4
200 4 –
210 – 2
220 2 1
230 1 1/0
240 1/0 2/0
250 2/0 3/0
260 3/0 4/0
270 4/0 –
Fuse Test Port
ATwo Direct Test Ports
Blank Two Capacitive Test Points
Housing
1Small
3Large**
Cable Insulation
Diameter (in.)
A0.575 in.–0.740 in. 15–19 mm
B0.635 in.–0.905 in. 16–23 mm
C0.805 in.–1.060 in. 20–27 mm
D0.890 in.–1.220 in. 25–31 mm
FLR Ø
* Small Housing is used with 8.3kV (3–45A) and 15.5kV (6–20A) rated fuses.
** Large Housing is used with 8.3kV (65A and 80A) and 17.2kV (3–45A) rated fuses.
1. All dimensions rounded up to the nearest eighth inch.
2. Also available with direct test port.
3. Dimensions with Direct Test Port units are 10-1⁄4 in. (260 mm) or 10-5⁄8 in. (270 mm).
4. 168FLR3 uses a large housing with a 15 kV, 200 A elbow interface.
168FLR1 274FLR1 168FLR3
274FLR3
6-1⁄4 in.
(159 mm)
10-5⁄8 in.
(270 mm)
6-1⁄4 in.
(159 mm)
10-5⁄8 in.
(270 mm)
9-1⁄4 in.
(235 mm)
A
10-5⁄8 in.
(270 mm)
10-1⁄2 in.
(270 mm)
A = 8-7⁄8 in. (225 mm)
A = 9-1⁄4 in. (235 mm)
8-7⁄8 in.
(225 mm)
Cable Accessories
A74
w w w . t n b . c a
Elastimold®
Molded Fuse Products
Full-Range Molded Current-Limiting Fuses
Application Information
Construction: Submersible, non-venting, deadfront, corrosion resistant
Ambient Temperature Range:
-30°C to 65°C for 6–50 A fuses;
-30°C to 40°C for >50 A fuses.
Certified Tests
Elastimold®Molded Current-Limiting Fuses have been designed and
tested per applicable portions of IEEE, ANSI, NEMA and other industry
standards, including:
ANSI C37.40 Standard for Current-Limiting Fuse
Service Conditions
ANSI C37.41 Standard for Current-Limiting Fuse
Design and Testing
ANSI C37.47 Standard for Current-Limiting Fuse
Ratings and Specifications
ANSI/IEEE 386 Standard for Separable Connectors and
Bushing Interfaces
Ratings
System Voltage Class (kV) 5 15 25/28* 35
Rated Maximum Fuse Voltage (kV) 5.5 8.3/10** 15.5/17.2** 23
Frequency (Hz) 50/60 50/60 50/60 50/60
BIL Impulse Withstand (kV) 60 95 125/140 150
One-Minute AC Withstand (kV) 34 34 40–45 50
Fifteen-Minute DC Withstand (kV) 53 53 78 103
Corona Extinction (kV) 11 11 19/21.5 26
Symmetrical Interrupting Capability (A) 50 50 50 50
Current Rating (A) 80–180 10–115 10–100 10–50
* 15.5 kV L-G rated fuses require 75 % grounded load to be applied on a 25 kV system.
** 17.2 kV L-G rated fuses require at least 75 % grounded load to be applied on a 28 kV system.
Fuse replacement requires the MCLF to be de-energized.
Fuses are only suitable for the system voltage class shown if the recovery voltage across the fuse will not
exceed its rated maximum voltage. For three-phase applications, this generally requires that protected
transformers be gndY-gndY and have at least 50 % grounded load.
Interchangeable
Molded Rubber
End Fittings
Assembled Fuse Unit
Replaceable Molded Rubber
Current-Limiting Fuse
Assembled Fuse Unit with Optional
Wall-Mounting Bracket
Elastimold®Cable Accessories
A75
w w w . t n b . c a
Molded Fuse Products
Full-Range Molded Current-Limiting Fuses
1. Designs have a 50,000 A all U/CERMSs Symmetrical Rating.
2. 10–50 A fuses have a Rated Maximum Application Temperature of 65°C, and 65–180 A fuses have a Rated Maximum Application Temperature of 40°C.
(RMAT is the maximum temperature of the air in contact with the MCLF housing at which the fuses have been shown suitable for use.)
3. Tabulated Maximum Total I2t values are for currents of 50,000 A at the nominal voltage of the fuse. Fuses that have a Rated Maximum Voltage higher than their Nominal Voltage Rating will
have a higher I2t let-through when applied at voltages up to these higher values. For example, Maximum Total I2t values are increased by approximately 30% when 8.3 kV fuses are applied at
10kV and approximately 25% when 15.5kV fuses are used at 17.2 kV.
4. Maximum total l2t values are reduced for currents below 50,000 A. For example, at 10,000 A, l2t values are approximately 15% less than the published values.
5. Peak arc voltages quoted are for 50,000A currents at the rated maximum voltage listed. Reduced currents and voltages will reduce the peak arc voltage. Consult the factory for further information.
6. Maximum continuous currents at higher ambient temperatures may be determined by derating the fuses by 0.2% per degree C over 25° C.
For example: At 40°C, the derating would be 15 x 0.2 = 3%, making the maximum continuous current of a 20 A fuse 23.0 x 0.97 = 22 A.
Electrical Characteristics of Encapsulated Fuses Used in MCLF
Nominal Fuse
Voltage Rating
(kV)
Current
Rating
(A)
Fuse
Catalogue
Number
Rated
Maximum
Voltage
(kV)
Maximum
Continuous
Current
(2) (6)
Peak Arc
Total l2t
(kV) (5)
Minimum
Melt l2t
(A2–Sec)
Maximum Total
l2t
(A2–Sec)
(3) (4)
25°C 40°C
5.5
80 M05CLF080
5.5
86 84
15
22,100 110,000
100 M05CLF100 108 105 56,700 280,000
125 M05CLF125 137 133 109,200 530,000
150 M05CLF150 159 154 176,000 860,000
180 M05CLF180 185 180 259,000 1,270,000
8.3
10 M15CLF010
10.0
14 13 28 800,000 4,000
20 M15CLF020 23 22
26
1,620 11,000
30 M15CLF030 35 33 5,250 30,000
40 M15CLF040 43 41 8,700 50,000
50 M15CLF050 51 47 12,800 70,000
65 M15CLF065
8.3
73 71
25
25,200 100,000
80 M15CLF080 87 84 47,000 185,000
100 M15CLF100 106 103 78,300 330,000
115 M15CLF115 120 116 115,150 480,000
15.5
10 M25CLF010
17.2
14 13 46 800,000 3,700
20 M25CLF020 23 22
45
1,620 10,000
30 M25CLF030 35 33 5,250 30,000
40 M25CLF040 43 41 8,700 50,000
50 M25CLF050 47 45 12,800 70,000
65 M25CLF065
15.5
68 66
40
25,200 110,000
80 M25CLF080 88 84 54,400 255,000
100 M25CLF100 100 100 80,000 380,000
23.0
10 M35CLF010
23.0
14 13 61 800,000 4,800
20 M35CLF020 23 22
60
1,620 13,000
30 M35CLF030 35 33 5,250 38,000
40 M35CLF040 41 40 8,700 61,000
50 M35CLF050 47 46 12,800 82,000
Elastimold®Cable Accessories
A76
w w w . t n b . c a
Molded Fuse Products
Full-Range Molded Current-Limiting Fuses
Recommended MCLF at 40°C Ambient Temperature
Recommended Fuse Current Ratings (Amperes)
Fuse Voltage (5.5 kV) 8.3 kV 15.5 kV 23 kV
1-Phase
Transformer kVA
Transformer 1-Phase Voltage Rating (kV), Phase to Ground
2.4 4.16 4.8 7.2 7.62 12 14.4 16 34.5
ABABABABABABABABAB
10 — 10a — 10a — 10a — 10a — 10a — 10a — 10a — 10a — 10a
15 10 — 10a — 10a — 10a — 10a — 10a — 10a — 10a — 10a
25 20 10 10 — 10a — 10a — 10a — 10a — 10a — 10a
37.5 20 30 20 20 10 10 — 10a — 10a — 10a — 10a
50 30 40 20 30 20 10 10 — 10a — 10a — 10a — 10a
75 50 65 30 40 20 30 — 20 — 20 — 10 — 10 — 10 — 10a
100 65 -80 40 50 30 50 20 30 20 30 — 20 — 10 — 10 — 10
167 -100 -150 65 -80 50 65 30 50 30 50 20 30 20 30 — 20 — 20
250 -150 (100) -125 -80 -100 50 65 50 65 30 50 30 40 20 30 20 30
333 -180 -125 -180 -100 -150 65 100 65 100 50 65 30 50 30 50 20 40
500 -180 -150 — 115 — 115 — 65 100 65 80 50 40
750 — — — — — — — — — — 100 80 100 — — — —
1 ————————————100—————
1. Column A = 140–200% of transformer rating and Column B = 200–300% of transformer rating.
2. Ratings in parentheses are 5.5kV fuses.
3. Recommended fuses meet inrush criteria of 12 times transformer full-load current for 0.1 second and 25 times transformer full-load current for 0.01 second.
Fuses also meet cold-load pickup criteria of 6 times transformer full-load current for 1 second and 3 times transformer full-load current for 10 seconds.
a. Fuse allows greater than 300% of transformer rating.
Recommended Fuse Current Ratings (Amperes)
Fuse Voltage 8.3 kV 15.5 kV (17.2 kV) 23 Kv
1-Phase
Transformer
kVA
Transformer 1-Phase Voltage Rating (kV), Phase to Ground
2.4 4.16 4.8 7.2–7.96 8.32 12.47 13.2–14.4 20.8 22.9–24.9 34.5
ABABABABABABABABABAB
15 — 10a — 10a — 10a — 10a — 10a — 10a — 10a — 10a — 10a — 10a
22.5 10 — 10a — 10a — 10a — 10a — 10a — 10a — 10a — 10a — 10a
30 10 — 10a — 10a — 10a — 10a — 10a — 10a — 10a — 10a — 10a
45 20 10 10 — 10a — 10a — 10a — 10a — 10a — 10a — 10a
75 30 40 20 20 10 10 — 10a — 10a — 10a — 10a — 10a
100 40 50 20 30 20 30 — 20 — 10 — 10 — 10 — 10a 10a 10a
112.5 40 65 20 30 20 30 — 20 — 20 — 10 — 10 — 10a 10a 10a
150 50 -80 30 50 30 40 20 30 — 20 — 10 — 10 — 10a 10a 10a
200 65 -100 40 65 40 50 20 30 20 30 — 20 — 20 — 10 — 10 — 10a
225 -80 -125 50 65 40 65 30 40 30 50 — 20 — 20 — 10 — 10 — 10a
300 -100 -150 65 -100 65 -80 40 50 30 50 20 30 20 30 — 20 10 20 — 10
500 -180 -100 -150 -100 -125 65 -80 50 80 30 50 30 50 20 30 20 30 — 20
750 — — -180 -125 -180 -80 -125 80 115 50 80 50 65 30 50 30 40 20 30
1,000 -180 -125 -180 115 — 65 100 65 100 50 65 40 65 30 40
1,500 — — — — — — -180 — — — 100 100 — 65 100 65 80 40
2,000 — — — — — — — — — — — — — — 100 — 80 — 50
Recommended MCLF at 40°C Ambient Temperature
Elastimold®Cable Accessories
A77
w w w . t n b . c a
Molded Fuse Products
Full-Range Molded Current-Limiting Fuses
Approx. Weight 30 lb. (13.6 kg)
16-5⁄8 in." (422mm)
19-1⁄2 in. (343 mm)
5-1⁄8 in.
(130 mm)
8-3⁄16 in.
(208 mm)
8-3⁄16 in.
(208 mm)
9-3⁄16 in.
(233 mm)
4 in.
(102 mm)
16-5⁄8 in. (422 mm)
16-5⁄8 in. (422 mm)
23-5⁄8 in. (343 mm)
27-5⁄8 in. (702 mm)
5-1⁄8 in.
(130 mm)
5-1⁄8 in.
(130 mm)
4 in.
(102 mm)
4 in.
(102 mm)
16-5⁄8 in. (422 mm)
19-5⁄8 in. (498 mm)
5-1⁄8 in.
(130 mm)
9/16 in.
(233 mm)
Model 22
Model 222
Model 2222
Model 66
Model 6E2
Approx. Weight 35 lb. (15.9 kg)
Approx. Weight 30 lb. (13.6 kg)
Approx. Weight 40 lb. (18.1 kg)
Approx. Weight 30 lb. (13.6 kg)
Lifting Eye
9⁄16 in. (14 mm) x 1 in.
(25 mm) Mounting
Slots on 5-1⁄2 in.
(140 mm) Centers
2-3⁄4 in.
(70 mm)
3⁄4 in. (19 mm)
11-1⁄8 in.
(283 mm) 6-3⁄8 in.
(162 mm)
18-5⁄8 in.
(473 mm)
22-1⁄2 in.
(572 mm)
5-1⁄8 in.
(130 mm)
Elastimold®Cable Accessories
A78
w w w . t n b . c a
Molded Fuse Products
Full-Range Molded Current-Limiting Fuses
Other models are available such as 26.
11-1⁄8 in.
(283 mm)
9⁄16 in. (14 mm) x 1 in. (25 mm)
Mounting Slots on
5-1⁄2 in. (140 mm) Centers
Lifting Eye
5-1⁄8 in.
(130 mm)
2-3⁄4 in.
(70 mm)
6-3⁄8 in.
(162 mm)
22-1⁄2 in.
(572 mm)
18-5⁄8 in.
(473mm)
1⁄2 in.
(13 mm)
Model 6E6
Approx. Weight 30 lb. (13.6kg)
The following diagram shows how to construct a catalog number for a Molded Current-Limiting Fuse:
Indicates field that must be filled in to complete order.
See page A75 for additional options.
See page A75 for additional options.
See outline drawings preceding this chart for additional details.
Voltage Class
55.0 kV
15 15.0 kV
25 25.0 kV
35 35.0 kV
Amperes
5 kV 15 kV 25 kV 35 kV
10 — 10 10 10
20 — 20 20 20
30 — 30 30 30
50 — 40 40 40
65 — 50 50 50
80 — 65 65 —
100 80 80 80 —
115 100 100 100
125 — 115 —
150 125 —
200 150 —
Mounting Brackets
WMB Wall Mounting Bracket with Parking Stands and
Bolted Style Hold Down Straps (HDS)
WMBQ Wall Mounting Bracket with Parking Stands and
Quick Release Style Hold Down Straps (QRS)
MCLF
Bushings
22 200 A Bushing Wells both ends
222 200 A Bushing Well on one end and two 200 A
Bushing Wells on the other end
2222 Two 200 A Bushing Wells on both ends
66 600 A Bushings on both ends
6E2 600 A Elbow Connector on one end and a 600 A Bushing on
the other end; this arrangement is not available at 35 kV
6E6
See page A79 for additional options.
Elastimold®Cable Accessories
A79
w w w . t n b . c a
15 to 60˚
Approx. Weight 8 lb. (3.6 kg) 9/16 in. (14 mm) x 1 in. (25 mm)
Mounting Slots
6-3/4 in.
(171 mm)
Optional WMB Mounting Bracket with Adjustable
Parking Stands for Vertical Mounting and Fuse Hold-Down Strips
Optional — TMA Universal Tilt Mounting
5-1/2 in.
(140 mm)
Mounting Options
29-3/4 in. (756 mm)
32-3/4 in. (832 mm)
Option No. Description
HDS Bolted-Style Hold-Down Strap (Qty: 1 required per end fitting)
QRS Quick-Release Style Hold-Down Strap (Qty: 1 required per end fitting)
WMB Wall-Mounting Bracket with Parking Stands and Bolted-Style Hold-Down Straps
WMBQ Wall-Mounting Bracket with Parking Stands and Quick-Release Style Hold-Down Straps
SMB Support Mounting Bracket for use with Models 6E2 or 6E6 end-fitting arrangements includes Bolted-Style Hold-Down Strap
TMA-EM Tilt Mounting Adapter bolts to bottom of Wall-Mounting Bracket WMB or WMBQ to enable up to 60º angle mounting (Qty: 2 required per installation)
Optional Fuse Mountings
Option No. Description System Voltage Class IEEE 386-1995 Interface Reference
EF2 200 A Bushing Well End Fitting 5, 15, 25, 35 Figure 3
EF22 Double 200 A Bushing Well End Fitting 5, 15, 25, 35 Figure 3
EF6 600 A Bushing End Fitting 5, 15, 25, 35 Figures 11 and 13
EF6E 600 A Elbow Connector End Fitting 5, 15, 25 Figure 11
End Fitting Catalogue Numbers
Option No. Description
MCLF-ADT Hex Wrench for set screw removal and replacement when disassembling end fittings. Supplied as standard with replacement fuses.
Assembly/Disassembly Tool
3/8 in. (10 mm)
Sq. Drive
3/16 in. (5 mm) Hex
Other Options
Molded Fuse Products
Full-Range Molded Current-Limiting Fuses
The option number may be added as a suffix to the MCLF catalogue number.
EF6E is equipped with a standard through-hole spade lug (Type 03700).
Use this table only if end fittings are to be ordered and shipped separately from the fuse. See pages A77-A78 for assembled units.
Elastimold®Cable Accessories
A80
w w w . t n b . c a
Surge Arresters
Metal Oxide Varistor (MOV) Surge Arresters
Fully shielded, fully submersible for convenient energized connection
with 200 A loadbreak or deadbreak components up to 35 kV
Voltage surges that exceed the BIL rating of the distribution system components will cause
damage to the installed equipment. To protect against these surges, overhead surge arresters are
widely used. Their application is understood since overhead lines and equipment are
directly affected by voltage surges (e.g. lightning). However, the use of overhead
arresters alone will not guarantee proper protection of the insulation in
the underground portion of an electrical distribution system. The
let through surge from the riser pole arresters into the
underground systems could be enough to cause damage to
the aging equipment insulation.
Elastimold®MOV Surge Arresters provide high-voltage
lightning and switching surge protection of transformers,
cable, equipment and other components typically located on
underground power distribution systems. Proper placement,
voltage selection and coordination with riser pole arresters
minimize damaging surge voltages by improving protective margins.
Typical applications include installing an arrester at the end of a radial
system or at both ends of an open point on a loop system. Additional
arresters can be added at strategic locations upstream from the end point
for optimum protection.
Metal Oxide Varistor (MOV) Surge Arresters are available in three styles:
Elbow (ESA), Parking Stand (PSA) and Bushing (BSA). The PSA and BSA
arresters permit direct connection, eliminating the need for additional
accessories. ESA Elbow Arresters are also available with a 200 A deadbreak
interface for mating with other deadbreak accessories.
The following page highlights the different installation options using Bushing and Parking Stand
Arresters where Elbow Arresters are normally used. Using BSAs and PSAs will contribute to
saving space inside transformers and improving operability.
IEEE 386 Interfaces; IEEE C62.11 Provide convenient energized
connection with other 200 A loadbreak or deadbreak components.
EPDM Molded Rubber Construction Fully shielded and fully
submersible for a variety of applications.
Compact Size Enables installation in your existing cabinetry,
saving you money.
Three Styles of Arresters Available Surge arresters fit your
application and are easy to install.
Direct Connection on PSA and BSA Versions Eliminates the need
for additional accessories, saving even more money.
#4 AWG Ground Lead Tethered to the Jacket Withstands
10,000 A for 10 cycles without fusing. Controls end plug when
ejected, preventing uncontrolled trajectory. Maintains the housing
shield ground connection after failure.
Ratings
High Current, Short Duration All MOV Arresters withstand two discharges of 40 kA crest
Low Current, Long Duration All MOV Arresters withstand 20 surges of
75 A/2,000 microseconds duration
Duty Cycle Test
All MOV Arresters withstand 22 operations of 5 kA crest at 8 x
20 microseconds duration while energized at rated voltage
for the initial 20 operations and at maximum continuous
operating voltage (MCOV) for the final two operations
Following each of the preceding tests, MOV Arresters demonstrate thermal recovery at MCOV.
Elastimold®Cable Accessories
A81
w w w . t n b . c a
Surge Arresters
Installation Options
PSAParking
Surge Arrester
BSA™ Bushing
Surge Arrester
Loadbreak Bushing
Insert
Loadbreak
Feed-Through Insert
Parking Stand
Feed-Through
Bushing Well
ESAElbow
Surge Arrester
Elastimold®Cable Accessories
A82
w w w . t n b . c a
Surge Arresters
Loop-Feed Circuit (Type 2 Transformer)
This is one approach using
elbow arresters only. (One of
the elbow arresters could
be mounted on the H1A
bushing if operating
procedures permit.)
This approach is best for increasing operability and reducing transformer
overcrowding. The bushing arrester enables the source cable to be
positioned on H1A, which conforms with some operating practices.
A bushing arrester mounted on H1A can be directed downward without
interference. Potential interference between an elbow arrester on H1B and a
cable parked on P is eliminated. The bushing arrester requires significantly
less space than an elbow arrester used with a feed-through insert.
Operability is enhanced because the open point can be closed by moving the
parked cable to H1B without removing an arrester.
An additional margin of protection may be gained by
adding an arrester at the next transformer upstream on
each side of the open point. This application is depen-
dent on the system voltage and condition of the cable.
If an additional arrester is added in the circuit, it can
be an elbow arrester in combination with a feed-
through insert or it can be a bushing arrester. Use of a
bushing arrester will reduce transformer faceplate
overcrowding.
Other configurations are possible, such as specifying a bushing arrester on every transformer. This enables the open point to be quickly and ea-
sily moved to any point in the circuit while maintaining the surge protection (without moving all of the portable surge arresters). The externally
mounted bushing arrester provides the surge protection benefits without the negative factors of an under-oil arrester.
* Transformers must be specified with bushing wells.
This approach can reduce
overcrowding (by
eliminating the
feed-through device). This
is desirable in a mini-pad
transformer.
Bushing Arrester and Parking Stand Arrester*
Additional Margin of Protection
Other Configurations
Elbow Arrester and
Parking Stand
Arrester
Two Elbow Arresters
and a Feed-Through
OR
Elastimold®Cable Accessories
A83
w w w . t n b . c a
Surge Arresters
Radial-Feed Circuit (End Point)
To add surge protection to a single-bushing transformer, utilize a bushing arrester
or an elbow arrester with a feed-through insert.
Single-Bushing Transformer
To add surge protection to a two-bushing transformer at the end point of a
radial-feed circuit, add an elbow arrester to the unoccupied bushing or utilize a
bushing arrester.
To convert a single-bushing transformer to a loop-feed, open-point transformer,
add a parking stand arrester and an elbow arrester in combination with a
feed-through insert.
Two-Bushing Transformer
Conversion of a Radial-Feed Transformer to a Loop-Feed,
Open-Point Transformer
Class MCOV*
(kV RMS)
Duty Cycle
Rating (kV RMS)
Maximum Discharge Voltage (kV Crest) 8 x 20 Microsecond Currentwave
1.5 kA 3 kA 5 kA 10 kA 20 kA
15kV 2.55 3 10.5 11.0 11.5 13.0 14.5
15kV 5.1 6 20.5 21.5 23.0 25.5 30.0
15kV 8.4 10 30.5 32.5 34.5 38.5 43.5
15kV 10.2 12 40.0 42.5 45.0 50.0 56.5
15kV 12.7 15 48.0 51.0 54.0 60.0 68.0
15kV 15.3 18 56.5 60.0 64.0 71.0 80.5
25kV 8.4 10 30.5 32.5 34.5 38.5 43.5
25kV 10.2 12 40.0 42.5 45.0 50.0 56.5
25kV 12.7 15 48.0 51.0 54.0 60.0 68.0
25kV 15.3 18 56.5 60.0 64.0 71.0 80.5
25kV 17.0 21 65.5 69.5 74.0 82.5 93.2
35kV 19.5 24 78.5 83.5 89.0 99.0 112.0
35kV 22.0 27 87.5 93.0 99.0 110.0 124.5
35kV 24.4 30 98.5 101.5 108.0 120.0 136.0
Protective Characteristics
* MCOV = Maximum Continuous Operating Voltage
Elastimold®Cable Accessories
A84
w w w . t n b . c a
Surge Arresters
MOV Surge Arresters
To specify and order an MOV Surge Arrester:
1) Determine the appropriate Maximum Continuous Operating Voltage (MCOV) for your
system voltage using the Arrester Application Table below.
2) Specify the appropriate Elastimold®catalogue number from the Selection Chart.
15 kV
Class
System Line-to-Line
Voltage kVrms MCOV* kV RMS
Nominal Maximum
Solidly
Grounded
Neutral
Circuits
3-Wire
Ungrounded
Circuits
2.40 2.54 2.55 2.55
4.16 4.40 2.55 5.10
4.80 5.08 5.10 5.10
6.90 7.26 5.10 8.40
8.32 8.80 5.10 8.40
12.47 13.20 8.40 15.30
13.20 13.97 8.40 15.30
13.80 14.50 8.40** 15.30
13.80 14.50 10.20 15.30
25 kV
Class
6.90 7.26 5.10 8.40
8.32 8.80 5.10 8.40
12.47 13.20 8.40 15.30
13.20 13.97 8.40 15.30
13.80 14.50 8.40** 15.30
13.80 14.50 10.20 15.30
20.78 22.00 12.70
20.78 22.00 15.30**
23.00 24.34 15.30
24.94 26.40 15.30
24.94 26.40 17.00**
28.00 29.80 17.00
Arrester Application Table
Cat. No. Description Voltage
Class
MCOV
kV RMS Picture
167BSA-3
BSA Bushing Surge Ar-
rester (includes assembly
tool) See Notes 1–4
15kV
2.55
167BSA-6 5.10
167BSA-10 8.40
167BSA-12 10.20
167BSA-15 12.70
167BSA-18 15.30
273BSA-10
25kV
8.40
273BSA-12 10.20
273BSA-15 12.70
273BSA-18 15.30
273BSA-21 17.00
167ESA-3
ESA Elbow Surge Arrester
See Notes 1, 2, 5
15kV
2.55
167ESA-6 5.10
167ESA-10 8.40
167ESA-12 10.20
167ESA-15 12.70
167ESA-18 15.30
273ESA-10
25kV
8.40
273ESA-12 10.20
273ESA-15 12.70
273ESA-18 15.30
273ESA-21 17.00
167PSA-3
PSA Parking Stand
Arrester See Notes 1–3
15 kV
2.55
167PSA-6 5.10
167PSA-10 8.40
167PSA-12 10.20
167PSA-15 12.70
167PSA-18 15.30
273PSA-10
25kV
8.40
273PSA-12 10.20
273PSA-15 12.70
273PSA-18 15.30
273PSA-21 17.00
Selection Chart
* MCOV = Maximum Continuous Operating Voltage.
** Preferred arrester MCOV for this system voltage.
1. Elastimold®PSA and BSA Arresters are equipped with a fully rated 200 A switching and fault-close loadbreak bushing.
2. Elastimold®Arresters use high-strength, silver epoxy-bonded MOV blocks and shunted spring connections
for the best circuit connection.
3. A 36 in. 4 AWG ground lead is provided with each unit.
4. BSA installed by turning internal hex bolt (accessed through the 200A bushing interface) with a 5⁄16" hex wrench and
bent-wire torque wrench supplied with each unit.
5. For 15 kV and 25 kV class deadbreak system Elbow Arresters, use catalog number 156ESA with the appropriate duty cycle rating.
Elastimold®Cable Accessories
A85
w w w . t n b . c a
To specify and order an MOV Surge Arrester:
1) Determine the appropriate Maximum Continuous Operating Voltage (MCOV) for your
system voltage using the Arrester Application Table below.
2) Specify the appropriate Elastimold®catalogue number from the Selection Chart.
35 kV
Class
System Line-to-Line
Voltage kVrms MCOV* kV RMS
Nominal Maximum
Solidly
Grounded
Neutral
Circuits
3-Wire
Ungrounded
Circuits
23.00 24.34 22.00
34.50 36.51 22.00**
34.50 36.51 24.40
Arrester Application Table
Cat. No. Description Voltage
Class
MCOV
kV RMS Picture
375BSA-24
BSA Bushing
Surge Arrester
See Notes 1–4
35 kV
19.50
375BSA-27 22.00
375BSA-30 24.40
375ESA-24
ESA Elbow
Surge Arrester
See Notes 2–3
19.50
375ESA-27 22.00
375ESA-30 24.40
375PSA-24
PSA Parking
Stand Arrester
See Notes 1–3
19.50
375PSA-27 22.00
375PSA-30 24.40
Selection Chart
1. Elastimold®PSA and BSA Arresters are equipped with a fully rated 200 A switching
and fault-close loadbreak bushing.
2. Elastimold®Arresters use high-strength, silver epoxy-bonded MOV blocks and
shunted spring connections for the best circuit connection.
3. A 36 in. 4 AWG ground lead is provided with each unit.
4. BSA installed by turning internal hex bolt (accessed through the 200 A bushing interface)
with a 5/16 in. hex wrench and bent-wire torque wrench supplied with each unit.
5. For 15 kV and 25 kV class deadbreak system Elbow Arresters, use catalogue number
156ESA with the appropriate duty cycle rating.
Surge Arresters
MOV Surge Arresters (cont’d)
* MCOV = Maximum Continuous Operating Voltage.
** Preferred arrester MCOV for this system voltage.
Elastimold®Cable Accessories
A86
w w w . t n b . c a
Molded Vacuum Recloser
The Elastimold®Recloser, in either single-phase or threephase
configurations, is fully compatible with SEL®Controls
Smart, Light and Flexible
The Elastimold®Recloser is world-class, by design. It responds to every hardware requirement
that utilities want.
Smart – Our recloser is Smart Grid ready with three integral load-side voltage sensors and provision to add
source-side voltage sensors, if desired. It was designed to be fully compatible with the industry’s
No. 1 name in controls, Schweitzer Engineering Laboratories.
Light – The three-phase Elastimold®Recloser weighs 33% less than existing typical units. The simplicity of
the mechanism design, and the compactness of the encapsulated components, contribute to making the
Elastimold®Recloser easier to move and install.
Flexible – The Elastimold®Recloser is modular, so field upgrades and retrofits are easy and fast. The single
phase recloser has a pole rotation mounting bracket for easier installation.
Made with Your Needs in Mind – We designed the Elastimold®Recloser only after extensive talks with
electric utilities. Its features, from easier-to-see open/close indicators to the many robust extra features that
we consider “standard”, are there because of you.
Side Silicone Terminal
Magnetic Actuator
Current Transformer
Vacuum Bottle
Pull Rod Assembly
Position Indicator
Load Side Voltage Sensor
Upper Cover
Lower Cover
Bottom Silicone Sheds
Solid Dielectric
Diaphragm
Main Body EPDM
Insulation
Top Silicone Sheds
Solid Dielectric Insulation
Lifting Rings
Highly-Visible
360° Indicators
Current & Voltage
Sensors
Integrated Pole
Mounting Bracket
Manual Tripping Lever
Recloser Operation
The Elastimold®Molded Vacuum Recloser (MVR) operates electrically by
energizing a magnetic actuator system with a completely sealed
housing. Each pole contains a vacuum interrupter sealed in solid
dielectric insulation for mechanical and high dielectric strength.
An open-closed position indicator provides a 360-degree view. An
external manual trip assembly is located on the side; when in the down
position, it maintains the recloser in a lockout position until it is manually
restored. All electrical control connections are made through a sealed
single-environment control cable connector on the side.
The combination of the molded vacuum recloser with microprocessor
controls accurately detects a wide range of line disturbances and
provides reliable, high-speed isolation for adverse conditions.
Elastimold®Cable Accessories
A87
w w w . t n b . c a
Molded Vacuum Recloser
Catalogue Numbering System
Indicates field that must
be filled in to complete order.
MVR
Interrupting Rating
12 25 kV
Future
Phases
1Single-Phase
3Three-Phase Voltage Class
15 15.0 kV
27 27.0 kV
38 38.0 kV
Source-Side Voltage Sensing
NNo
1One Voltage Sensor
3Three Voltage Sensors
Cat. No. Description
3188D0120G1 Three-phase Line Side Arrester Frame
3188D0121G1 Three-phase Load Side Arrester Frame
3188C0122G1 Single-phase Line Side Arrester Frame
3188C0123G1 Single-phase Load Side Arrester Frame
3070A1191P1 Wildlife Protector Top Bushing (one per phase)
3070A1190P1 Wildlife Protector Side Bushing (one per phase)
3188C0075G1 Source-side Voltage Sensors (one per phase)
3188D0119G1 Substation Mounting Frame
3188B0126G1 NEMA 2-hole pad
3180A0661P1 NEMA 4-hole pad
3070B0913G1 Aerial Lug
1548FH-ANC3JNAA Fisher Pierce®Overhead Faulted Circuit Indicator – Adaptive TripTM; 4 hr automatic reset time with current reset override
(60 sec. after restoration of power), five ultra-bright LEDs for increase visibility display
1548FH-ANC3XNA1 Fisher Pierce®Overhead Faulted Circuit Indicator – Adaptive TripTM; 4 hr automatic reset time with current reset override
(60 sec. after restoration of power), with 4 hr temporary fault reset time, temporary fault indication option, four red and one amber LED
Accessories
Control Model
1SEL-351R, SEL-351R Falcon(14-pin)
2SEL-651R (32-pin)
3SEL-351RS Kestrel®(single-phase only)
Sequential Numbers*
Sequential Numbers*
Control, Cable Length and
Other Accessories
Ratings and Specifications
15 kV 27 kV 38 kV*
Nominal System Voltage (kV RMS) 14.4 25 35
Rated Maximum Voltage (kV RMS) 17.1 29.3 38
Nominal Frequency (Hz) 50 or 60 50 or 60 50 or 60
Phase Spacing on Three-Phase Units (Inches) 15.5 15.5 15.5
BIL (kV) 150 150 170
Power Frequency Withstand — Dry (kV) 50 50 70
Power Frequency Withstand — Wet (kV) 45 45 60
Continuous Current (A RMS) 800 800 800
Eight (8) Hour Overload Current (A RMS) 960 960 960
CT Ratio 1,000 to 1 1,000 to 1 1,000 to 1
15 kV 27 kV 38 kV*
Interrupting Current (kA RMS Symmetrical) 12.5 12.5 12.5
Making Current (kA Asymmetrical Peak) 32.5 32.5 32.5
Creepage Distances (Inches — Line to Ground) 41.5 41.5 41.5
Arc-Extinction Medium Vacuum Vacuum Vacuum
Insulation Medium EPDM/Silicon Rubber EPDM/Silicon Rubber EPDM/Silicon Rubber
Mechanical Operations 10,000 10,000 10,000
Operating Temperatures –40°C to 65°C –40°C to 65°C –40°C to 65°C
Voltage Sensor Accuracy (Load/Line) 3% / 1% 3% / 1% 3% / 1%
CT Accuracy Class 1 Class 1 Class 1
Weight (Single–Phase/Three-Phase) 57 lb. / 208 lb. 57 lb. / 208 lb. 58 lb. / 211 lb.
* Single phase 38 kV units are rated for use on grounded systems only. Three-phase 38 kV units can be used for single-phase tripping on grounded systems only.
For ungrounded systems, three-phase tripping is required.
* Consult your T&B sales representative for
complete catalogue number configuration.
SEL is a registered trademark of Schweitzer
Engineering Laboratories, Inc.
Head Office
19295 25th Avenue
Surrey, BC V3Z 3X1
Tel: 778-545-9916
Fax: 778-545-3099
Toll Free: 1-888-467-7626
Terrace
5000 Pohle Avenue
Terrace, BC V8G 4S8
Tel: 250-635-6379
Prince George
2255 S. Quinn Street
Prince George, BC V2N 2X4
Tel: 250-563-0575
Kitimat
622 Commercial Avenue
Kitimat, BC V8C 2C5
Tel: 250-632-3774
Fort Nelson
PO Box 3266 - 5016 48th Avenue
Fort Nelson, BC V0C 1R0
Tel: 250-233-8570
Dawson Creek
1101 97th Avenue
Dawson Creek, BC V1G 1N5
Tel: 250-782-4896
Williams Lake
527 S. MacKenzie Avenue
Williams Lake, BC V2G 1C8
Tel: 250-392-7795
Vernon
5203 24th Street
Vernon, BC V1T 8X7
Tel: 250-545-2191
Penticton
401 Okanagan Avenue
Penticton, BC V2A 3K1
Tel: 250-492-4032
Kamloops
B-983 Camosun Crescent
Kamloops, BC V2C 6G1
Tel: 250-374-3191
Cranbrook
Unit A #800 Industrial Road. #2
Cranbrook, BC V1C 4C9
Tel: 250-489-4591
Parksville
#105 - 425 E. Stanford Avenue
Parksville, BC V9P 2N4
Tel: 250-954-1797
Duncan
5286 Polkey Road
Duncan, BC V9L 6W3
Tel: 250-748-3377
Courtenay
2615 Moray Place
Courtenay, BC V9N 8A9
Tel: 250-334-0338
Campbell River
1030 B - 9th Avenue
Campbell River, BC V9W 4C2
Tel: 250-287-9265
Surrey
13055 80th Avenue
Surrey, BC V3W 3B1
Tel: 604-596-7111
Richmond
12360 Vickers Way
Richmond, BC V6V 1H9
Tel: 604-273-1981
Langley
#101 - 20550 Duncan Way
Langley, BC V3A 7A3
Tel: 604-533-1275
Burnaby
3935 2nd Avenue
Burnaby, BC V5C 3W9
Tel: 604-292-4800
Lighting Specialist
Tel: 778-545-9916
Projects Group
Tel: 604-596-7111
Data Communications Group
Tel: 778-545-9916
Process, Automation &
Controls Group
Tel: 778-545-9916
Unit 9, 7223 68 Avenue,
Edmonton, Alberta T6B 3T6

Navigation menu