17518 Brochure

138241-Catalog 138241-Catalog 138241-Catalog B4 unilog cesco-content

138241-Catalog 138241-Catalog 138241-Catalog B5 unilog cesco-content

156421-Catalog 156421-Catalog 156421-Catalog B5 unilog cesco-content

2016-09-04

: Pdf 1000424690-Brochure 1000424690-Brochure B4 unilog

Open the PDF directly: View PDF PDF.
Page Count: 56

18-1
© 2009 Schneider Electric
All Rights Reserved
18 IEC CONTACTORS AND
STARTERS
Table of Contents
Section 18
TeSys® IEC Contactors and Starters
TeSys D Contactors (p. 18-4)
TeSys F Contactors (p. 18-5)
GV7 Manual Motor Starters
and Protectors (p. 18-35)
GV3P (p.18-33)
LUB2 (p. 18-28)
GV2P21 (p.18-33)
New!
Contactors
TeSys D 18-4
TeSys D Reversing 18-6
TeSys F 18-5
TeSys K 18-24
TeSys D and F Accessories 18-8
TeSys K Accessories 18-27
Motor Starters and Protectors
TeSys U 18-28
GV2, GV3, GV7 Manual Motor Protectors 18-33
Enclosed D-Line 18-21
GV Accessories 18-34
LS1D Fuse Block 18-36
Overload Relays
TeSys D 18-4
TeSys F 18-5
TeSys D and F Accessories 18-16
TeSys K 18-24
TeSys K Accessories 18-27
TeSys T 16-92
Soft Start Module ATS01 18-32
Replacement Parts
TeSys D Coils 18-17
TeSys F Coils 18-20
TeSys F Contact Tips, etc. 18-13
Wiring Systems
GV-Line Bus Bars 18-37
TeSys D Quickfit 18-38
AK5 18-39
Dimensions 18-40
For more information on lighting, definite purpose (DP), and elevator ratings for TeSys D
and TeSys F contactors, please refer to catalog 8502CT9901.
For more information on machine safety applications using TeSys D and TeSys F,
please refer to catalog MKTED208051EN-US.
See our website, www.schneider-electric.us, for UL 508A short circuit ratings (SCCR).
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-2 © 2009 Schneider Electric
All Rights Reserved
3 Pole Contactors TeSys® D AC and DC Contactors
Refer to Catalog 8502CT9901
sOn LC1D09 - LC1D65A, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex. LC1D12G7 becomes
LC1D123G7 and LC1D40AG7 becomes LC1D40A3G7 - Note that 40A to 65A spring terminals are only on the control terminations and not on power
terminations). No price adder for this modification.
tOn LC1D09 - LC1D65A and LC1DT20 through LC1DT80A, for ring tongue versions add '6' to the catalog number prior to adding the voltage code
(ex. LC1D09G7 becomes LC1D096G7 and LC1D50AG7 becomes LC1D50A6G7). No price adder for this modification.
Note: To be used for interpretation of current catalog numbers only.
LC _____ D_____ _____ _____ _____
Full Voltage, Non-Reversing 1
Full Voltage, Reversing 2
TeSys D 3 Pole Contactors 9A to 150A
Contactor AC-3 Full Load Amps (FLA)
9A FLA 09
12A FLA 12
18A FLA 18
25A FLA 25
32A FLA 32
38A FLA (not marketed in US) 38
40A FLA 40
50A FLA 50
65A FLA 65
80A FLA 80
95A FLA (not marketed in US) 95
115A FLA 115
150A FLA 150
Everlink Power Connection (40A to 65A only) A
No Everlink Power Connection (9A to 32A, 80A to 150A) Blank
Termination Options (choose one)
Screw Termination Blank
Spring Terminations s 3
Ring Tongue Terminations t 6
Slip-on Terminations (9A to 12A only) 9
Coil Voltage (choose one)
AC Coils (50/60 Hz) DC Coils (standard) DC Coils
low consumption available
for 9 to 38 amp only
12V J7 12V JD 5V AL
21V Z7 21V ZD 12V JL
24V B7 24V BD 21V ZL
36V C7 36V CD 24V BL
42V D7 48V ED 48V EL
48V E7 60V ND 72V SL
60V EE7 72V SD 96V DL
100V K7 110V FD 110V FL
110V F7 125V GD 220V ML
115V FE7 220V MD 250V UL
120V G7 250V UD
127V FC7 440V RD
200V L7
208V LE7
220V M7
230V P7
240V U7
277V W7
380V Q7
400V V7
415V N7
440V R7
480V T7
500V S7
575V SC7
600V X7
660V Y5
(50 Hz only)
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-3
2, 3, and 4 Pole
Contactors
TeSys® F AC and DC Contactors
Refer to Catalog 8502CT9901
LC _____ F_____ _____ _____ _____
Full Voltage, Non-Reversing 1
Full Voltage, Reversing 2
TeSys F 2, 3, and 4 Pole Contactors 115A to 800A
Contactor AC-3 Full Load Amps (FLA)
115A FLA 115
150A FLA 150
185A FLA 185
225A FLA 225
265A FLA 265
330A FLA 330
400A FLA 400
500A FLA 500
630A FLA 630
780A FLA 780
800A FLA 800
Number of Poles
2 Poles (400A, 500A, and 630A only) 2
3 Poles (all sizes) Blank
4 Poles (all sizes except 800A) 4
Termination Options - Purchase Lugs Separately Blank
Coil Voltage (choose one and note contactor size it can be used on)
AC Coils For use on: DC Coils For use on:
24V (50 Hz) B5 LC1F115 - F225 24V BD LC1F115 - F400
24V (60 Hz) B6 LC1F115 - F225 48V ED LC1F115 - F630
24V (40-400 Hz) B7 LC1F225 - F400 110V FD LC1F115 - F780
42V (50 Hz) D5 LC1F115 - F225 110V FW LC1F800
48V (50 Hz) E5 LC1F115 - F225 125V GD LC1F115 - F780
48V (60 Hz) E6 LC1F115 - F225 220V MD LC1F265 - F780
48V (40-400 Hz) E7 LC1F115 - F630 220/240V MW LC1F800
110V (50 Hz) F5 LC1F115 - F225 250V UD LC1F115 - F780
110V (60 Hz) F6 LC1F115 - F225 380/400V QW LC1F800
110V (40-400 Hz) B7 LC1F115 - F780 440V RD LC1F115 - F780
115V (50 Hz) FE5 LC1F115 - F225
115V (40-400 Hz) FE7 LC1F115 - F780
120V (60 Hz) G6 LC1F115 - F225
120V (40-400 Hz) G7 LC1F115 - F400
120V (40-400 Hz) F7 LC1F500 - F780
127V (60 Hz) G6 LC1F115 - F225
127V (40-400 Hz) G7 LC1F115 - F780
200/208V (60 Hz) L6 LC1F115 - F225
200/208V (40-400 Hz) L7 LC1F265 - F780
208V (40-400 Hz) L7 LC1F115 - F225
220V (50 Hz) M5 LC1F115 - F225
220V (60 Hz) M6 LC1F115 - F225
220V (40-400 Hz) M7 LC1F115 - F780
230V (50 Hz) P5 LC1F115 - F225
230V (40-400 Hz) P7 LC1F115 - F800
240V (50 Hz) U5 LC1F115 - F225
240V (60 Hz) U6 LC1F115 - F225
240V (40-400 Hz) U7 LC1F115 - F780
277V (50 Hz) W5 LC1F115 - F225
277V (40-400 Hz) W7 LC1F115 - F780
380V (50 Hz) Q5 LC1F115 - F225
380V (60 Hz) Q6 LC1F115 - F225
380V (40-400 Hz) Q7 LC1F115 - F780
400V (50 Hz) V5 LC1F115 - F225
400V (40-400 Hz) V7 LC1F115 - F800
415V (50 Hz) N5 LC1F115 - F225
415V (40-400 Hz) N7 LC1F115 - F780
440V (50 Hz) R5 LC1F115 - F225
440V (40-400 Hz) R7 LC1F115 - F780
460/480V (60 Hz) Q6 LC1F115 - F225
480V (40-400 Hz) N7 LC1F780
500V (50 Hz) S5 LC1F115 - F225
500V (40-400 Hz) S7 LC1F115 - F780
600V (40-400 Hz) X7 LC1F500 - F630
660V (60 Hz) Y6 LC1F115 - F225
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-4 © 2009 Schneider Electric
All Rights Reserved
Contactors &
Overload Relays
TeSys® D Non-reversing
Refer to Catalog 8502CT9901
TeSys D contactor accessories . . . . . . . . . . . . . . . . . . . . pages 18-8 to 18-11
TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
TeSys T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-91
LC1D09
LC1D40A
LC1D093
LC1D115
LRD22
LRD3
E164862
CCN NLDX
LR43364
Class 3211 04
Table 18.1: 3- or 4-Pole Screw Terminal Connections
Maximum Horsepower Ratings
Maximum Current
Utilization
Categories
No of Poles
Instantaneous
Auxiliary
Contacts Catalog
Number a
$ Price
Single Phase Three Phase Inductive
AC3
Amperes
Resistive
AC1
Amperes
N.O. N.C. N.O. N.C.
115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp AC Coils DC Coils
0.51 2 2 57.59
20
3011
LC1D09 cde 94.00 119.00
——————— 4 LC1DT20 c94.00 119.00
——————— 22 LC1D098
c94.00 119.00
12337.51012
25
3011
LC1D12 cde 119.00 149.00
——————— 4 LC1DT25
c119.00 149.00
——————— 22 LC1D128 c119.00 149.00
1355101518
32
3011
LC1D18 cd 136.00 160.00
——————— 4 LC1DT32 c149.00 183.00
——————— 22 LC1D188 c149.00 183.00
2 3 7.5 7.5 15 20 25
40
3011
LC1D25 cd 151.00 181.00
——————— 4 LC1DT40 c193.00 240.00
——————— 22 LC1D258 c193.00 240.00
2 5 10 10 20 30 32 50 3 0 1 1 LC1D32 cd 172.00 213.00
3 5 10 10 30 30 40 60 301 1 LC1D40A 218.00 275.00
—————— 4 00LC1DT60A296.00 353.00
3 7.5 15 15 40 40 50
80
3011 LC1D50A 234.00 291.00
5 102020405065 3 LC1D65A322.00 379.00
——————— 4000LC1DT80A446.00 503.00
7.5152530606080
125
301 1 LC1D80 363.00 420.00
—————— 4 00
LC1D80004 b489.00 524.00
——————— 22 LC1D80008 b489.00 524.00
30 40 75 100 115
200
3
011 LC1D115 479.00 479.00
40 50 100 125 150 3 LC1D150 696.00 696.00
— — — — — — 4 0 0 LC1D115004 630.00 630.00
aComplete catalog number with coil voltage code from table on page 18-6; example, LC1D09G7.
bFor DC version of these devices replace the 'C' with 'P' (ex. LC1D80004** becomes LP1D80004**). This applies only to 80A 4 pole devices.
cOn LC1D09 - LC1D65A and LC1DT20 through LC1DT80A, for ring tongue versions add '6' to the catalog number prior to adding the voltage code
(ex. LC1D09G7 becomes LC1D096G7 and LC1D50AG7 becomes LC1D50A6G7). No price adder for this modification.
dOn LC1D09 - LC1D65A, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex. LC1D12G7 becomes
LC1D123G7 and LC1D40AG7 becomes LC1D40A3G7 - Note that 40A to 65A spring terminals are only on the control terminations and not on power
terminations). No price adder for this modification.
eOn LC1D09 and LC1D12 only, for slip-on connector versions add "9" to the catalog number prior to adding the voltage code (ex. LC1D09G7 becomes
LC1D099G7). No price adder for this modification.
Table 18.2: TeSys D Overload Relays — Ambient Compensated, Bi-Metallic Direct Mount
Current Setting
Range Amperes
For Direct Mounting
to LC1... Class 10 with
Single Phase
Sensitivity
Class 10 without
Single Phase
Sensitivity
Class 20 with
Single Phase
Sensitivity
Class 20 without
Single Phase
Sensitivity
$ Price
0.10–0.16
D09–D32
LRD01 LR3D01 ——
60.00
0.16–0.25 LRD02 LR3D02 ——
0.25–0.40 LRD03 LR3D03 ——
0.40–0.63 LRD04 LR3D04 ——
0.63–1 LRD05 LR3D05 ——
1–1.6 LRD06 LR3D06 ——
1.6–2.5 LRD07 LR3D07 ——
2.5–4 LRD08 LR3D08 LRD1508 LR3D1508A1
4–6 LRD10 LR3D10 LRD1510 LR3D1510A1
5.5–8 D09–D32 LRD12 LR3D12 LRD1512 LR3D1512A1
62.00
7–10 D09–D32 LRD14 LR3D14 LRD1514 LR3D1514A1
9–13 D12–D32 LRD16 LR3D16 LRD1516 LR3D1516A1
12–18 D18–D32 LRD21 LR3D21 LRD1521 LR3D1521A1
16–24 D25–D32 LRD22 LR3D22 ——
17–25 D25–D32 LRD1522 LR3D1522A1
23–32 D25–D32 LRD32 LR3D32 ——
73.00
23–28 D25–D32 LRD1530 LR3D1530A1
25–32 D25–D32 LRD1532 LR3D1532A1
30–38 D32 LRD35 LR3D35 ——
9-13 D40A-D65A fLRD313 LR3D313 LRD313L
107.00
12-18 D40A-D65A fLRD318 LR3D318 LRD318L
16-25 D40A-D65A fLRD325 LR3D325 LRD325L
23-32 D40A-D65A fLRD332 LR3D332 LRD332L
30-40 D40A-D65A fLRD340 LR3D340 LRD340L
37-50 D40A-D65A fLRD350 LR3D350 LRD350L
48-65 D40A-D65A fLRD365 LR3D365 LRD365L
17-25 D40-D80 gLRD3322 LR3D3322 LR2D3522 LR3D3522
107.00
23-32 D40-D80 gLRD3353 LR3D3353 LR2D3553 LR3D3553
30-40 D40-D80 gLRD3355 LR3D3355 LR2D3555 LR3D3555
37-50 D50-D80 gLRD3357 LR3D3357 LR2D3557 LR3D3557
48-65 D50-D80 gLRD3359 LR3D3359 LR2D3559 LR3D3559
55–70 D65–D80 LRD3361 LR3D3361 LR2D3561 LR3D3561
127.0063–80 D65–D80 LRD3363 LR3D3363 LR2D3563 LR3D3563
80–104 D80 LRD3365 ——
80–104 D115–D150 LRD4365 ——
362.0095–120 D115–D150 LRD4367 ——
110–140 D150 LRD4369 ——
fOverload relays with Everlink termination - direct mount to D40A to D65A only.
gDirect mount to old D2 style D40 to D65 (no Everlink terminations) and to D80 only.
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-5
Contactors &
Overload Relays
TeSys® F Non-reversing
Refer to Catalog 8502CT9901
aComplete part number by adding coil voltage code from table below. For example: LC1F115G7. All contactors (except F780) include 1 N.O. coil
interlock contact.
TeSys F contactor accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-11
TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-49
LC1F115
E164862
CCN NLDX
LR43364
Class 3211 04
Table 18.3: TeSys D Overload Relays — Solid State
Current Setting Range Amperes For Direct Mounting Beneath
Contractor LC1 Class 10 Class 20 $ Price
60–100 D115–D150 LR9D5367 LR9D5567 298.00
90–150 D115–D150 LR9D5369 LR9D5569 298.00
Table 18.4: TeSys F 2-, 3-, and 4-Pole Contactors
Standard power ratings of 3-phase motors 50/60 Hz in
category AC-3 Maximum Current
Number of
Poles
Catalog
Number a
$ Price200 V
208 V
220 V
240 V
460 V
480 V
575 V
600 V AC-3 AC-1 Panel Mount with Screws
HP HP HP HP A A
30 40 75 100 115 200 3LC1F115 479.00
4LC1F1154 630.00
40 50 100 125 150 250 3LC1F150 696.00
4LC1F1504 825.00
50 60 125 150 185 275 3LC1F185 938.00
4LC1F1854 1439.00
Current Rated 225 315 3LC1F225 1059.00
4LC1F2254 1935.00
60 75 150 175 265 350 3LC1F265 1179.00
4LC1F2654 1646.00
75 100 200 250 330 400 3LC1F330 1621.00
4LC1F3304 1846.00
100 125 250 300 400 500
2LC1F4002 1521.00
3LC1F400 1874.00
4LC1F4004 2133.00
150 200 400 500 500 700
2LC1F5002 4324.00
3LC1F500 4970.00
4LC1F5004 5617.00
250 300 600 800 630 1000
2LC1F6302 5917.00
3LC1F630 6474.00
4LC1F6304 7582.00
Current Rated 780 1600 3LC1F780 7788.00
4LC1F7804 9940.00
450 800 900 800 1000 3 LC1F800 6676.00
Table 18.5: TeSys F 3-Phase Overload Relays — Solid State Separate Mount b
Current Setting Range
Amps
For Direct Mounting to Contactor
LC1●●●●
Class 10 Trip c
Catalog Number
Class 20 c
Catalog Number $ Price
30–50 F115–F185 LR9F5357 LR9F5557 298.00
48–80 F115–F185 LR9F5363 LR9F5563 298.00
60–100 F115–F185 LR9F5367 LR9F5567 298.00
90–150 F115–F185 LR9F5369 LR9F5569 298.00
132–220 F185 d –F265 LR9F5371 LR9F5571 298.00
200–330 F265–F500 LR9F7375bLR9F7575b333.00
300–500 F265–F500 LR9F7379bLR9F7579b737.00
380–630 F400–F630 LR9F7381bLR9F7581b905.00
bWhen mounting overload relays LR9F557 to LR9F571 directly beneath the contactor, supporting the relays with a mounting plate is recommended.
With overload relays LR9F775 to LR9F781, use of a support mounting plate is mandatory.
cIEC standard 60947-4 specifies the following trip times when the overload relay senses 7.2 times the setting current:
Class 10 — between 4 and 10 seconds
Class 20 — between 6 and 20 seconds
dInterconnection kit LA7F407 is required to mount an LR9F71 to an LC1F185.
Table 18.6: Coil Voltage Codes h
Contactor Hz 24 V 48 V 110 V 120 V 125 V 208 V 220 V 240 V 250 V 440 V 480 V 600 V
AC
D09–D150 50/60 B7 E7 F7 G7 LE7 M7 U7 T7 eX7 ef
LC1D80–LC1D150 only 60 B6 E6 F6 G6 L6 M6 U6 T6 X6 f
50 B5 E5 F5 M5 eU5————
F115, F150, and F185 50B5E5F5———M5U5————
60 B6 E6 F6 G6 L6 M6 U6 Q5 SC
F265, and F330 40–400 B7 E7 F7 G7 L7 M7 U7 S7iX7
F400— F780 40–400 E7 F7 G7 L7 M7 U7 N7 X7 g
DC
D09-D32, DT20-D258
Low Consumption BLELFL———MLUL——
D09–D150 BD ED FD GD MD UD RD
F115-F330 BD ED FD GD MD UD RD
F400–F780 ED FD GD MD UD RD
eNot available for LC1D80 - LC1D150
fNot available for LC1D115 or LC1D150
gNot available for LC1F780. The 600 V coils for the LC1F400 - LC1F630 do not include an auxiliary contact for holding circuits.
hFor additional voltage codes refer to the IEC Contactor and Starter Catalog 8502CT9901.
iFor use with F265—F330 only.
Table 18.7: Coil Voltage Codes for AC and DC Voltages for F800 (includes built-in surge suppressor)
Volts AC/DC 24 48 110 120 127 208 220 240 277 380 415 440 480 575 600 660
50/60 HZ FW FW FW MW MW QW QW QW
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-6 © 2009 Schneider Electric
All Rights Reserved
Contactors TeSys® D 3- and 4-Pole Reversing, AC or DC Operating Coil
Refer to Catalog 8502CT9901
Each 3-pole device is pre-wired with line and load side power wiring for reversing applications.
Each 4-pole device is pre-wired with load side power wiring
TeSys D contactor accessories . . . . . . . . . . . . . . . . . . . . pages 18-8 to 18-11
TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
LC2D09
E164862
CCN NLDX
LR43364
Class 3211 04
Table 18.8: 3-Pole & 4-Pole Mechanically Interlocked Contactors
Maximum Horsepower Ratings Maximum Current No. of N.O.
Power
Poles
Built In Auxiliary
Contacts
(per contactor)
Catalog
Number
ab
$ Price
Single Phase Three Phase Inductive
AC3
Amperes
Resistive
AC1
Amperes
AC
Control
DC
Control
115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp N.O. N.C.
0.512257.59 20 3 1 1 LC2D09c234.00 317.00
—————— — 411LC2DT20234.00 317.00
12337.51012 25 3 1 1 LC2D12c317.00 368.00
—————— — 411LC2DT25317.00 368.00
1355101518 35 311LC2D18c344.00 400.00
—————— — 32 411LC2DT32419.00 443.00
2 3 7.5 7.5 15 20 25 40 3 1 1 LC2D25c374.00 436.00
—————— — 411LC2DT40456.00 477.00
2 5 10 10 20 30 32 50 3 1 1 LC2D32c415.00 503.00
3 5 10 10 30 30 40 60 3 1 1 LC2D40A 565.00 650.00
3 7.5 15 15 40 40 50 70 3 1 1 LC2D50A 596.00 680.00
5 1020205050 65 80 311LC2D65A778.00 857.00
7.5 15 30 30 60 60 80 125 311 d
—————— — 4d
— 30 40 75 100 115 200 311LC2D115 e1165.00 1165.00
—————— 4LC2D115004 e1391.00 1391.00
40 50 100 125 150 200 3 1 1 LC2D150e1598.00 1598.00
aUse voltage codes from the “Voltage Codes” table below to complete the catalog number. For example: LC2D09G7
bIncludes mechanical interlock without electrical contacts. Installer to complete wiring for electronically interlocking contactor operating coils by utilizing
a N.C. auxiliary contact integrated in the contactor or optional LADN or LAD8N auxiliary contact block.
cFor LC2D09–LC2D32, electrical interlock can be included by adding a ”V” to the end of the catalog number (ex: LC2DO9B7V). List price adder: $5.00.
dFor these items, order two non-reversing contactors and one mechanical interlock separately. See page 18-4 and 18-14 for selection.
eIncludes mechanical interlock (Type LA9D11502) with pre-wired electrical contacts for interlocking contactor operating coils.
Table 18.9: Coil Voltage Codes i
Contactor Hz 24 V 48 V 110 V 120 V 125 V 208 V 220 V 240 V 250 V 440 V 480 V 600 V
AC
D09–D150 50/60 B7 E7 F7 G7 LE7 M7 U7 T7 fX7 f
LC1D80–LC1D150 50 B5 E5 F5 M5 fU5————
60 B6 E6 F6 G6 L6 M6 U6 T6 X6 gf
F115, F150, F185 50 HzB5E5F5———M5U5————
60 Hz B6 E6 F6 G6 L6 M6 U6 Q5 SC
F265, F330 40–400 Hz B7 E7 F7 G7 L7 M7 U7 S7 jX7
F400–F780 40–400 Hz E7 F7 F7 L7 M7 U7 N7 X7 h
DC
D09-D32,
DT20-D258
Low Consumption
BLELFL———MLUL———
D09–D150 BD ED FD GD MD UD RD
F115–F330 BD ED FD GD MD UD RD
F400–F780 — — ED FD GD MD UD RD — —
fNot available for LC1D80 - LC1D150.
gNot available for LC1D115 or LC1D150.
hNot available for LC1F780. The 600 V coils for the LC1F400 - LC1F630 do not include an auxiliary contact for holding circuits.
iFor additional voltage codes refer to the IEC Contactor and Starter Catalog 8502CT9901.
jFor use with F265—F330 only.
Table 18.10: Coil Voltage Codes for AC and DC Coil Voltages for F800 (includes built-in surge suppressor)
Volts AC/DC 24 48 110 120 127 208 220 240 277 380 415 440 480 575 600 660
50/60 Hz FW FW FW MW MW QW QW QW
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-7
Contactors TeSys® F 3-Pole Reversing, AC or DC Operating Coil
Refer to Catalog 8502CT9901
HOW TO ORDER:
Components are available for customer assembly of TeSys F reversing contactors. For
example, the following components must be ordered to build a 75 hp @ 460 V reversing
contactor with a 120 V/60 Hz coil:
TeSys F contactor accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-11
TeSys F overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-42
Table 18.11:
Quantity Catalog Number Description
2 LC1F115G6 Contactors
6 DZ2FF1 Lugs (page 18-12)
2 LADN11 Auxiliary contacts
1 LA9FF976 Power connections
1 LA9FF970 Mechanical interlock
Table 18.12: 3-Pole Contactors
Maximum Horsepower Ratings Maximum Current Holding Circuit
Contact Built
Into Coil Catalog
Numbera$ Price
Three Phase Inductive
AC3
Amperes
Resistive
AC1
Amperes
200 V
hp
230 V
hp
460 V
hp
575 V
hp N.O. N.C.
30 40 75 100 115 200 1 0 LC1F115 479.00
40 50 100 125 150 250 1 0 LC1F150 696.00
50 60 125 150 185 275 1 0 LC1F185 938.00
60 75 150 200 265 350 1 0 LC1F265 1179.00
75 100 200 250 330 400 1 0 LC1F330 1621.00
100 125 250 300 400 500 1 0 LC1F400 1874.00
150 200 400 500 500 700 1 0 LC1F500 4970.00
250 300 600 800 630 1000 1 0 LC1F630 6872.00
Current rated 780 1600 0 0 LC1F780 7788.00
450 800 900 800 1000 0 0 LC1F800 6676.00
aUse coil voltage codes from the “Voltage Codes” table on page 18-6 to complete the contactor catalog number.
Table 18.13: Auxiliary contact (electrical interlocking) - 2 must be purchased
For use with Number of
Contacts
Maximum Number
of Blocks
Per Contactor
Contact Arrangement Catalog Number $ Price
LC1F
to be ordered
separately
11
1—LADN10 13.10
—1LADN01 13.10
22
11LADN11 20.70
2-LADN20 20.70
42
22LADN22 41.50
13LADN13 41.50
4—LADN40 41.50
—4LADN04 41.50
31LADN31 41.50
22 bLADC22 41.50
bincluding 1 N.O. + 1 N.C. make-before-break
Table 18.14: AccessoriesFor the assembly of three-pole reversing contactors
(horizontal mounting)
With 2 Identical
Contactors c
Set Of Power Connections
Catalog Number $ Price
Horizontal Mounting
Mechanical Interlock Kit
Catalog Number
$ Price
LC1F115 LA9FF976 106.00 LA9FF970 53.00
LC1F150 LA9F15076 96.00 LA9FF970 53.00
LC1F185 LA9FG976 113.00 LA9FG970 53.00
LC1F265 LA9FH976 151.00 LA9FJ970 76.00
LC1F330 LA9FJ976 225.00 LA9FJ970 76.00
LC1F400 LA9FJ976 198.00 LA9FJ970 76.00
LC1F500 LA9FK976 306.00 LA9FJ970 76.00
LC1F630, F800 LA9FL976 568.00 LA9FL970 76.00
cFor two contactors of different size, refer to pages 18-15.
LC1F265
E164862
CCN NLDX
LR43364
Class 3211 04
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-8 © 2009 Schneider Electric
All Rights Reserved
Contactor
Accessories
TeSys® D & F Auxiliary Contacts, Time Delay, Mechanical Latch
Refer to Catalog 8502CT9901
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6
TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
Table 18.15: Standard, instantaneous auxiliary contact blocks
Snap-On
Mounting
Number of
Contacts
Composition Catalog Number a$ Price
N.O. N.C.
To front of
LCDT20–D258 (4P),
LCD09–D150a
or
To right side of
LCF
4 a
22 LADN22 b 41.50
13 LADN13 b41.50
40 LADN40 b41.50
04 LADN04 b41.50
31 LADN31 b41.50
2 c2 cLADC22 bc 41.50
2
11 LADN11 b20.70
20 LADN20 b20.70
02 LADN02b20.70
To front of
LCD80 and D115
or
To left side of
LCF
1
10 LADN10 d13.10
01 LADN01 d13.10
To side of
LCD09 to D150 only
(not for use on TeSys F)
211LAD8N11 e20.70
20 LAD8N20 e20.70
aFor low consumption coils (LC1D09 to D32 only), only one front-mounted two-contact block allowed. No side-
mounted contact blocks allowed.
bFor spring terminal versions of these blocks, add a “3” to the end of the catalog number. (Ex. LADN223). No price
adder for this modification.
cIncluding 1 N.O. + 1 N.C. make before break overlapping contacts.
dThis block cannot be added to the LC1D 09 to D32 contactors; a maximum of 2 blocks can be mounted on the
LC1D40A to LC1/LP1D80 contactors only.
e1 block may be added to the left side of the LC1D 09 to D32, AC coils only; 1 block may be added to each side of
the LC1D 40A to D80 contactors, AC coils only. Cannot be installed on TeSys D contactors with DC coils.
Table 18.16: Instantaneous blocks with dust-tight auxiliary contacts (IP54)
NEMA 12
Snap-On
Mounting
Standard Contacts Dusttight Contacts Catalog Number $ Price
N.O. N.C. N.O. N.C.
To front of
LPD40–D80, LCDT20–D258 (4P),
LCD09 to D80
or
To right side of
LCF
—— 2 — LA1DX20 65.00
2—2LA1DZ40 82.00
112LA1DZ31 82.00
—— 2 — LA1DY20f77.00
fDevice supplied with 4 ground terminal points.
Table 18.17: Pneumatic time delay contact blocks
Snap-On
Mounting
Time Delay
Contacts Type Range of
Time Delay
Catalog
Number h$ Price
N.O. N.C.
To f ront of
LPD40–D80,
LCDT20–D258 (4P),
LCD09 to D150
or
To right side of
LCF
11
On energization
(on delay)
0.1 to 3 sgLADT0 131.00
0.1 to 30 s LADT2 131.00
10 to 180 s LADT4 131.00
1 to 30 siLADS2 131.00
11
On de-energization
(off-delay)
0.1 to 3 sgLADR0 131.00
0.1 to 30 s LADR2 131.00
10 to 180 s LADR4 131.00
gScale range is expanded between 0.1 and 0.6 seconds on the dial for more accurate settings at the lower end of
the range.
hFor spring terminal versions of these blocks, add a “3” to the end of the catalog number. (Ex. LADT23). No price
adder for this modification.
iWith switching time of 40 ms ± 15 ms between the opening of the N.C. contact to the closing of the N.O. contact.
Table 18.18: Mechanical latch blocks with manual or electrical unlatch
(TeSys D only)
Front snap-on
mounting onto Application
Catalog number
to be completed
by the code corresponding
to the coil voltage
$ Price
LCD09 to D65A For silent operation and energy
conservation LAD6K10jk 77.00
LC1 D80 to D150 LP1 D80 For silent operation and energy
conservation LA6DK20jk 77.00
jDoes not include internal coil clearing contact.
kComplete catalog number by adding coil voltage code. For example: LAD6K10F.
Table 18.19: Coil Voltage Codes for LA6DK mechanical latch blocks
Volts 12 24 32/36 42/48 60/72 100 110/
127
200/
208
220/
240
380/
415
440/
480
500/
600
AC or DC J B C E EN K F L M Q R S
Front Mounted
Auxiliary Blocks
(shown on TeSys D
contactor)
E164862
CCN NLDX
LR43364
Class 3211 04
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-9
Contactor Accessories TeSys® D Coil Suppressors, Cabling Accessories
Refer to Catalog 8502CT9901
RC Coil Suppressor
Limitation of transient voltage to 300% of nominal voltage maximum
Oscillating frequency limited to 400 Hz maximum. Slight increase in drop-out time (1.2 to 2 times normal)
Varistor Coil Suppressor
Limitation of transient voltage value to 200% of nominal voltage maximum
Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times normal)
Diode Coil Suppressor
No overvoltage or oscillating frequency
Polarized component. Increased drop-out time (6 to 10 times normal)
Bidirectional Diode Coil Suppressor
Protection provided by limiting the transient voltage to 2 Uc max.
Maximum reduction of transient voltage peaks
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6
TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
Table 18.20: Resistor/capacitor circuit (RC) for reduction of “electrical noise” in AC contactor coils
Installed by Mounting on Operating voltage 50/60 Hz Catalog Number $ Price
Snapping into cavity on right side without toolsbLC1D09 to LC1D32 (3P)
LCDT20 to DT40 (4P),
24–28 V LAD4RCE 26.20
50–127 V LAD4RCG 26.20
110–240 V LAD4RCU 26.20
Snap-on mounting and connection without tools to the
contactor coil terminals
LC1D40A to LC1D65A (3P),
LC1DT60A to LC1DT80A
(4P)
24-48 V LAD4RC3E 26.20
50-127 V LAD4RC3G 26.20
110-240 V LAD4RC3U 26.20
380-415 V LAD4RC3N 26.20
Screw connection to the contactor coil terminals LCD80 to D150 (3 or 4P)
LCD80 to D115 (4P)
24–48 V LA4DA2E 26.20
50–127 V LA4DA2G 26.20
110–240 V LA4DA2U 26.20
380–415 V LA4DA2N 26.20
Table 18.21: Varistor (peak limiting) for reduction of “electrical noise” in AC or DC contactor coils
Installed by Mounting on Operating voltage 50/60 Hz Catalog Number $ Price
Snapping into cavity on right side without toolsbLCD09 to D32a
TeSys D contactors
24–48 V LAD4VE 26.20
50–127 V LAD4VG 26.20
110–250 V LAD4VU 26.20
Snap-on mounting and connection without tools to the
contactor coil terminals
LC1D40A to LC1D65A (3P),
LC1DT60A to LC1DT80A
(4P)
24-48 V LAD4V3E 26.20
50-127 V LAD4V3G 26.20
110-250 V LAD4V3U 26.20
Screw connection to the contactor coil terminals LCD80 to D115 (3P or 4P)
LCD12, D25 (4P)
24–48 Vac LA4DE2E 26.20
50–127 Vac LA4DE2G 26.20
110–250 Vac LA4DE2U 26.20
Screw connection to the contactor coil terminals LCD80 (3P or 4P)
24–48 Vdc LA4DE3E 26.20
50–127 Vdc LA4DE3G 26.20
110–250 Vdc LA4DE3U 26.20
aFor DC coils 3-pole contactors are fitted with built-in surge suppression as standard.
Table 18.22: Diode for reduction of “electrical noise” in DC contactor coils
Installed on the upper part by Mounting on Operating voltage DC Catalog Number $ Price
Snap-on mounting and connection w/o tools to the contactor coil terminals LCD09 - D32 24–250 V LAD4DDL 26.20
Clip-on front mounting LCD40A to D65,
D65A to DT80A 24–250 V LAD4D3U 26.20
Screw connection of wire to the contactor coil terminals D80 (3P)
D80 (4P) 24–250 V LA4DC3U 26.20
Table 18.23: Bidirectional peak limiting diode
Installed by Mounting on Operating Voltage 50/60 Hz and DC Catalog Number $ Price
Snapping into cavity on right side of contactor bLCD09 to LCD32 (3P)c
DT20 to DT40 (4P)
24 (AC only) LAD4TB 26.20
72 (AC only) LAD4TS 26.20
Clip-on front mounting and connection without tools
to the contactor coil terminals c
LC1D40A to LC1D65A (3P),
LC1DT60A to LC1DT80A
(4P)
12 - 24 V LAD4T3B 26.20
25 - 72 V LAD4T3S 26.20
73 - 125 V LAD4T3G 26.20
126 - 250 V LAD4T3U 26.20
251 - 440 V LAD4T3R 26.20
Screw Mounting dLCD80
24 (AC only) LA4DB2B 56.00
72 (AC only) LA4DB2S 26.20
24 (DC only) LA4DB3B 56.00
72 (DC only) LA4DB3S 56.00
bInstalling suppressor into the cavity makes the electrical connection. Overall width of contactor remains the same.
cFor LCD09 through LCD65A with DC or low consumption DC coils, 3-pole contactors are fitted with built-in bidirectional diode suppression as
standard.
dMounting at the top of the contactor on coil terminals A1 and A2.
Table 18.24: Cabling Accessories
Usage Mounting on Operating voltage 50/60 Hz Catalog Number $ Price
For adapting existing wiring to a new product or for use with
top mount accessory.
LC1D09 to D38
LC1DT20 to DT60
AC only
Without coil suppression LAD4BB 23.00
With coil
suppression
(varistor)
24-48 V LAD4BBVE 23.00
50-127 V LAD4BBVG 23.00
110-250 V LAD4BBVU 23.00
For adapting existing wiring to a new product or for use with
top mount accessory
LC1D40A to LC1D65A
(with no coil suppressor) LAD4BB3 26.20
LA4DA1U
LA4DA2U
LA4DC3U
LAD4BB• •
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-10 © 2009 Schneider Electric
All Rights Reserved
The following accessories require use of cabling accessories (LAD4BB●●) for proper mounting. See page 18-9 for
illustration.
Electronic Serial Timer Modules
These solid state modules delay the energizing and de-energizing of the contactor coil.
Interface Modules b
These modules allow the contactor coils to be energized from low voltage and low current level signals. They come in
mechanical relay and solid state versions. The relay plus manual operation versions include a lever for manually
turning the contactor on and off. When a module receives a low level signal, it allows the separate sourced control
voltage to flow to the contactor coil. It saves space and wiring time compared to conventional interposing relays.
bAdapter required for D09 - D65A, see table 18.24.
Automatic-Manual-Stop Control Modules
These modules allow for local and/or remote operation of the contactor coil. Each module includes a lever to switch
from automatic to manual operation and a dial to turn the contactor on and off.
Low Voltage Ride Through Module (meets SEMI F47 requirements)
By ensuring SEMI F47 compliance of AC powered IEC contactors and relays, the low voltage ride through modules can
be used to increase the voltage sag immunity of semiconductor processing equipment. These modules make it
possible for AC powered Telemecanique contactors and relays to exceed the requirements of SEMI F47, both in the
magnitude and duration of a voltage sag event—even with accessories such as auxiliary contact blocks and pneumatic
timers.
The low voltage ride through modules can be used with Telemecanique contactors from 9 A through 80 A, as well as
the CAD series of control relays
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6
TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
Table 18.25:
Type Operational Voltage aTime Delay Catalog Number $ Price
24–250 Vac 100–250 Vac
On-delay LC1D09–D65A LC1D80–D150
0.1–2 s LA4DT0U 82.
1.5–30 s LA4DT2U 82.
25–500 s LA4DT4U 82.
aFor 24 V operation, the contactor must be fitted with a 21 V coil: coil voltage code Z5 for 50 Hz; Z6 for 60 Hz; ZD for DC.
Table 18.26:
Interface Type Operational Voltage Input Voltage Catalog Number $ Price
24–250 Vac 100–250 Vac
Relay LC1D09–D150 24 Vdc LA4DFB 55.
LC1D09–D150 48 Vdc LA4DFE 55.
Relay Plus LC1D09–D150 24 Vdc LA4DLB 71.
Manual Operation LC1D09–D150 48 Vdc LA4DLE 71.
Solid State LC1D09–D65 LC1D80–D115 24 Vdc LA4DWB 71.
LA4DFB
Table 18.27:
Operational Voltage Catalog Number $ Price
24–100 Vac 100–250 Vac
LC1D09–D150 — LA4DMK 35.
Table 18.28:
For use on: Catalog Number $ Price
Contactor Relay
LC1D●●B7 CAD●●B7 LADLVRT24V c 124.
LC1D●●G7 CAD●●G7 LADLVRT120V c124.
LC1D●●LE7 CAD●●LE7 LADLVRT208V c 124.
Top mount bracket (required when using above modules) D09 - D32 LAD4BB c23.
Top mount bracket (required when using above modules) D40 - D65 LAD4BB3 c23.
Fuse LA9D941 120.
cLAD4BB must be used when the low voltage ride through module is being used with contactors 32 A and less, and TeSys CAD Series of Control Relays.
The LAD4BB3 must be used with the D40 - D65A. See table 18.24 on page 18-10.
E2
E1
A2
A2
A1
A1
1.25
32
LADLVRT
1.85
47
LAD4BB
E1 E2
A1 A2
LADLVRT
Contactors 40 A–80 AContactors 32 A and less
Contactor Accessories TeSys® D Electronic Timers and Interface Modules
Refer to Catalog 8502CT9901
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-11
Contactor Accessories TeSys® D and F Accessories
Refer to Catalog 8502CT9901
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6
TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-18 to 18-19
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7
TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20
Table 18.29: For Power Pole or Control Connection
Description
For use with
contactors
LC1/LP1
Sold in
lots of
Catalog
Number $ Price each
Connectors for
larger cable sizes
4 poles #8 AWG (10 mm2)D09, D12 1 LAD92560 8.70
3 poles #4 AWG (25 mm2) D09–D32 1 LA9D3260 12.00
Everlink® terminal
block 3 poles D40A-D65A 1 LAD96560 10.00
Links
for the parallel
connection of
2 poles
D09–D32 10 LA9D2561 26.20
D40A–D65A 1 LAD9P32 6.00
D80 2 LA9D80961 6.50
F115 4 LA9FF602 55.00
F150, F185 4 LA9FG602 65.00
F265, F330, F400 4 LA9FH602 169.00
F500 4 LA9FK602 228.00
F630, F800 4 LA9FL602 278.00
3 poles
(Wye-Delta
Shorting Strap)
D09–D32 10 LAD9P3 10.00
D40A-D65A 1 LAD9P33 25.00
D80 1 LA9D80962 6.50
F115 1 LA9FF601 6.80
F150, F185 1 LA9FG601 8.20
F265, F330, F400 1 LA9FH601 12.00
F500 1 LA9FK601 21.80
F630, F800 1 LA9FL601 38.20
4 poles DT20, DT25 2 LA9D1263 8.70
D80 2 LA9D80963 17.50
Second coil connection LP1D40–D80 10 LA9D09966 2.20
Control circuit take-off from main pole D115, D150 10 LA9D11567 4.00
D80 10 LA9D8067 5.50
Spreaders for increasing pole pitch to 45 mm D115, D150 3 GV7AC03 31.10
Table 18.30: For Marking
Description
For use with
contactors
LC1/LP1
Sold in
lots of
Catalog
Number $ Price each
Reference label holder snap-on 8 x 22 mm 4-pole contactors
D80 - D115 100 LA9D92 .06
Reference label holder snap-on 8 x 18 mm 3 poles D09-D65A, DT20-DT80A,
LADN, LADT, LADR 100 LAD90 .06
Sheet of 300 labels self adhesive 7 x 21 mm For holder LA9D92 1 LA9D93 4.30
Table 18.31: For Mounting
Description
For use with
contactors
LC1/LP1
Sold in
lots of
Catalog
Number $ Price each
Set of shims for mounting LAD8N and LA8DN D80 1 LA9D511 9.80
Retrofit plate for replacement of LC1D40-D65 with
LC1D40A-D65A D40A-D65A 1 LAD7X3 25.00
35 mm DIN Rail – 2 meters long LC1D09 to D80 10 AM1DP200 5.20
Table 18.32: Replacement contacts
For use with
contactors
Catalog
Number $ Price
Three-pole LC1D115 3 poles LA5D1158031 239.00
LC1D150 3 poles LA5D150803 239.00
Four-pole LC1D115 4 poles LA5D115804 318.00
Table 18.33: Arc chambers
For use with
contactors
Catalog
Number $ Price
Three-pole LC1D115 3 poles LA5D11550 90.00
LC1D150 3 poles LA5D15050 90.00
Four-pole LC1D115 4 poles LA5D115450 119.00
LA9D1260
LA9D2561
LA9D40961
LA9D6567
LA9D511
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-12 © 2009 Schneider Electric
All Rights Reserved
Contactor Accessories TeSys® F Contactors
Refer to Catalog 8502CT9901
These clear plastic protective shrouds are an effective means to meet international touch-safe requirements for power
terminals. They are designed to be used with power cables that have been bolted to the terminal.
NOTE: The protection shrouds do not attach to contactors or overloads utilizing DZ2F lug kits.
For contactors LC1F115, LC1F150, and LC1F185, an available touch-safe terminal block may be used in place of lugs
for power connections.
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-5, 18-7
TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys F replacement coils and parts . . . . . . . . . .pages 18-18, 18-18, 18-20
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47
LA9D09981
LA9F980
Table 18.34: Suppressor Blocks
Operating limit: up to 220 V, 50/60 Hz coils
Description For Use Catalog Number $ Price
Suppressor block
(clip-on mounting to coil)
With coils LX1FF, FG, FH, F115, F150, F185, F225, F265, F330 LA9F980 21.80
With coils LX1FJ, FK, FL, FX, F400, F500, F630, F780, LX9FF, FG, FH, F115, F150, F185, F225,
F265, F330 LA9D09980 20.70
Mounting bracket (for 35 mm DIN rail or panel mounting) for suppressor block LA9D09981 5.50
Table 18.35: Lugs and Lug Kits a
Contactor
Type LC1
Lug Kit Catalog
Number
Contactor Only
Cable Size AWG
range Overload Relay
Directly
mounted to
contactor
Lugs Required Cable size AWG range
LC1Line side of
contactor
Load side of
overload
Line side of
contactor
Load side of
overload
F115 DZ2FF6 14 to 2/0 LR9F557 to F569 F115 3 each DZ2FF1 3 each DZ2FG1 14 to 2/0 6 to 3/0
F150, F185 DZ2FG6 6 to 3/0 LR9F557 to F571 F150 to F185 1 each DZ2FG6 6 to 3/0
—LR9F571 F225, F265 1 each DZ2FH6 6 to 300 MCM
F225, F265,
F330 DZ2FH6 6 to 300 MCM LR9F775 to F779 F265 or F330 3 each DZ2FH1 6 to 300 MCM 4 to 500 MCM
F400 DZ2FJ6 4 to 500 MCM LR9F775 to F781 F400 3 each DZ2FJ1 4 to 500 MCM 4 to 500 MCM
F500 DZ2FK6 2 x 2 to 600 MCM LR9F775 to F781 F500 3 each DZ2FK1 2x2 to 600 MCM 4 to 500 MCM
F630, F800 DZ2FL6 3 x 2 to 600 MCM LR9F781 F630
1 each DZ2FL1
DZ2FL2
DZ2FL3
1 each DZ2FR1 3x2 to 600 MCM 4 to 500 MCM
F780 DZ2FX6 4 x 1/0 to 750 MCM
aLug kits ending in the number “6” include 6 identical lugs. In some cases the LR9F overload relay mounted directly on the load side of an LC1F contactor
will require a different size lug for your choice of contactor and overload. If the two sizes are different, order 3 of each size lug. Mounting hardware (screws,
washers, and nuts) are provided with the contactors and overload relays, not with the lugs. See Table 18.37 for pricing.
Table 18.36: Lugs—2 and 4-Pole c
Contactor
Type LC1
Lug Kit
Catalog Number
Qty. Required AL/CU
Cable Size
2-Pole 4-Pole
F115 DZ2FF1 4 8 14 to 2/0
F150, F185 DZ2FG1 4 8 6 to 3/0
F225, F265, F330 DZ2FH1 4 8 6 to 300 MCM
F400 DZ2FJ1 4 8 4 to 500 MCM
F500 DZ2FK1 4 8 2 X 2 to 600 MCM
F630 DZ2FLbbb3 X 2 to 600 MCM
F780 DZ2FX1 4 8 4 X 1/0 to 750 MCM
bFor 2-pole F630 contactors, order 2 DZ2FL1 (L1 and T2), and 2 DZ2FL3 (L2 and T1).
For 4-pole F6304, order 2 DZ2FL1 (L1 and T4), 4 DZ2FL2 (L2, T2, L3, T3) and 2 DZ2FL3 (L4 and T1).
cLugs for LC1F contactors and overload relays must be ordered separately. Each kit consists of one (1) lug. Mounting hardware (screws, washers, nuts)
are provided with the contactors, not the lugs. See Table 18.37 for pricing.
Table 18.37: Lugs Pricing
Lug Catalog Number $ Price Lug Catalog Number $ Price
DZ2FF6 39.30 DZ2FH1 11.00
DZ2FG6 65.00 DZ2FJ1 11.00
DZ2FH6 65.00 DZ2FK1 21.80
DZ2FJ6 65.00 DZ2FL1 27.30
DZ2FK6 131.00 DZ2FL2 55.00
DZ2FL6 164.00 DZ2FL3 27.30
DZ2FX6 163.80 DZ2FR1 173.30
DZ2FF1 6.50 DZ2FX1 27.30
DZ2FG1 11.00
LA9F70z
Table 18.38: Power Terminal Protection Shrouds
For Use With 2-, 3-, And 4-pole Contactors Number of Shrouds
Per Set Catalog Number $ Price
LC1F115 6LA9F701 42.40
LC1F150, F185 6LA9F702 61.00
LC1F225, F265, F330, F400 and F4002, F500 and F5002 6 LA9F703 82.00
LC1F630, F6302 and F800 6 LA9F704 93.00
LC1F1154 8LA9F706 58.00
LC1F1504 and F1854 8LA9F707 80.00
LC1F2254, F2654, F3304, F4004, F5004 8 LA9F708 111.00
LC1F6304 8LA9F709 120.00
Table 18.39: Insulated Terminal Blocks
For contactor
type LC1
For overload
relay LR9
Maximum
Cable Size Catalog Number $ Price
F115, F150, F185 F557, F563, F567, F569 300 MCM LA9F103 55.00
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-13
Replacement Parts TeSys® F Contact Kits, Arc Chambers
Refer to Catalog 8502CT9901
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7
TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys F replacement coils and parts . . . . . . . . . . pages 18-13, 18-18, 18-20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47
LA5FG431
LA5F11550
Table 18.40: Replacement contact sets a
For use on contactors Catalog Number $ Price
Two-pole
LC1F4002 2 poles LA5F400802 717.
LC1F5002 2 poles LA5F500802 1111.
LC1F6302 2 poles LA5F630802 1651.
Three-pole
LC1F115, F150 3 poles LA5FF431 239.
LC1F185 3 poles LA5FG431 418.
LC1F265 3 poles LA5FH431 793.
LC1F330, F400 3 poles LA5F400803 1076.
LC1F500 3 poles LA5F500803 1589.
LC1F630 3 poles LA5F630803 2488.
LC1F780 1 pole LA5F780801d1651.
LC1F800 3 poles LA5F800803 2488.
Four-pole
LC1F1504, F1154 4 poles LA5FF441 318.
LC1F1854 4 poles LA5FG441 549.
LC1F2654 4 poles LA5FH441 966.
LC1F3304, F400, F4004 4 poles LA5F400804 1435.
LC1F5004 4 poles LA5F500804 2461.
LC1F6304 4 poles LA5F630804 3304.
LC1F7804 1 pole LA5F780801d1651.
Table 18.41: Arc chambers
For use on contactors Catalog Number $ Price
Two-pole
LC1F4002 2 poles LA5F400250 280.
LC1F5002 2 poles LA5F500250 305.
LC1F6302 2 poles LA5F630250 431.
Three-pole
LC1F115 3 poles LA5F11550 90.
LC1F150 3 poles LA5F15050 101.
LC1F185 3 poles LA5F18550 179.
LC1F265 3 poles LA5F26550 269.
LC1F330 3 poles LA5F33050 287.
LC1F400 3 poles LA5F40050 305.
LC1F500 3 poles LA5F50050 341.
LC1F630 3 poles LA5F63050 646.
LC1F780 1 pole LA5F780150d431.
LC1F800 3 poles LA5F80050 750.
Four-pole
LC1F1154 4 poles LA5F115450 119.
LC1F1504 4 poles LA5F150450 131.
LC1F1854 4 poles LA5F185450 248.
LC1F2654 4 poles LA5F265450 299.
LC1F3304 4 poles LA5F330450 414.
LC1F4004 4 poles LA5F400450c573.
LC1F5004 4 poles LA5F500450c610.
LC1F6304 4 poles LA5F630450b861.
LC1F7804 1 pole LA5F780150d431.
aSupplied per pole are: 2 fixed contacts, 1 moving contact, 2 deflectors, 1 backplate, mounting screws and washers.
bComprises single-pole components.
cComprises 2-pole components.
d2 identical components per pole are supplied.
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-14 © 2009 Schneider Electric
All Rights Reserved
Contactors Accessories TeSys® D Reversing Contactors
Refer to Catalog 8502CT9901
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-4, 18-6
TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
Table 18.42: Contactors Mechanical interlock Set of power connections
Reversing contactors comprising two identical,
horizontally mounted contactors:
Without electrical
interlock
With incorporated
electrical interlock
(2 N.C. contacts)
Reversing contactors
for motor control
Four pole
contactors
Catalog
Number $ Price Catalog Number $ Price Catalog Number $ Price Catalog Number $ Price
LC1D09, LC1D12, LC1D18, LC1D25, LC1D32 LAD9R1e32.10 LAD9R1Ve45.50 Included with kit Not Available
LC1DT20, LC1DT25, LC1DT32, LC1DT40 LADT9R1e36.90 LADT9R1Ve45.50 Not Available Included with kit
eKit including mechanical interlock and wiring.
LC1D40, LC1D50, LC1D/LP1D65 LA9D50978 31.70 LA9D4002 45.90 LA9D6569 53.00 LA9D6570 63.00
LC1D40A, D50A, D65A LAD4CM 45.00 Not Available LA9D65A69 75.00 Not Available
LC1D80 AC coil LA9D50978 31.70 LA9D4002 45.90 LA9D8069 65.00 LA9D8070 79.00
LC1D80 DC coil LA9D80978 31.70 LA9D8002 65.00 LA9D8069 65.00 LA9D8070 79.00
LC1D115 and LC1D150 Not Available LA9D11502 78.00 LA9D11569 129.00 LA9D11571
(3P) 53.00
LA9D11570
(4P) (D115 only) 53.00
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-15
Contactors Accessories TeSys® F Reversing Contactors
Refer to Catalog 8502CT9901
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7
TeSys F overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys F replacement coils and parts . . . . . . . . . . . . . . .pages 18-18 to 18-20
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-42 to 18-47
Table 18.43: Component parts for the assembly of F-Line 3-pole reversing
contactors
With
2 Identical
Contactors a
Set of Power Connections
Catalog Number $ Price Mechanical Interlock Kit
Catalog Number $ Price
Horizontal Mounting
LC1F115 LA9FF976 106.00 LA9FF970 53.00
LC1F150 LA9F15076 96.00 LA9FF970 53.00
LC1F185 LA9FG976 113.00 LA9FG970 53.00
LC1F265 LA9FH976 151.00 LA9FJ970 76.00
LC1F330 LA9FJ976 225.00 LA9FJ970 76.00
LC1F400 LA9FJ976 225.00 LA9FJ970 76.00
LC1F500 LA9FK976 306.00 LA9FJ970 76.00
LC1F630 or F800 LA9FL976 568.00 LA9FL970 76.00
Vertical Mounting
LC1F115 or F150 dLA9FF4F 97.00
LC1F185 dLA9FG4G 113.00
LC1F265 dLA9FH4H 126.00
LC1F330 dLA9FJ4J 149.00
LC1F400 dLA9FJ4J 149.00
LC1F500 dLA9FK4K 149.00
LC1F630 or F800 dLA9FL4L 149.00
LC1F780 bLA9FX970 b508.00
Table 18.44: Component parts for the assembly of TeSys F 3-pole or 4-pole transfer
contactors
Horizontal
Mounting
Set of Power Connections
$ Price
Mechanical
Interlock Kit
Catalog Number
$ Price
Three-Pole Four-Pole
LC1F115/4 LA9FF982 LA9FF977 53.00 LA9FF970 53.00
LC1F150/4 LA9F15082 LA9F15077 53.00 LA9FF970 53.00
LC1F185/4 LA9FG982 LA9FG977 53.00 LA9FG970 53.00
LC1F265/4 LA9FH982 LA9FH977 83.00 LA9FJ970 76.00
LC1F330/4 LA9FJ982 LA9FJ977 113.00 LA9FJ970 76.00
LC1F400/4 LA9FJ982 LA9FJ977 113.00 LA9FJ970 76.00
LC1F500/4 LA9FK982 LA9FK977 154.00 LA9FJ970 76.00
LC1F630/4 LA9FL982 LA9FL977 233.00 LA9FL970 76.00
Vertical Mounting
LC1F115/4 dd LA9FF4F 97.00
LC1F185/4 dd LA9FG4G 113.00
LC1F265/4 dd LA9FH4H 149.00
LC1F330/4 dd LA9FJ4J 149.00
LC1F400/4 dd LA9FJ4J 149.00
LC1F500/4 dd LA9FK4K 149.00
LC1F630/4 dd LA9FL4L 149.00
LC1F780/4 bc LA9FX970 c508.00
Table 18.45: Vertical mounting of 2 contactors of different ratings a
Upper Contactor Lower Contactor eMechanical Interlock Kit
Catalog Number $ Price
LC1F185 or 1854 LC1F115/150 or 1154/1504 LA9FG4F 113.00
LC1F265 or 2654 LC1F115/150 or 1154/1504 LA9FH4F 126.00
LC1F330 or 3304 LC1F185/1854 or 265/265A LA9FH4G 126.00
LC1F400 or 4004
LC1F115/150 or 1154/1504 LA9FJ4F 126.00
LC1F185 or 1854 LA9FJ4G 126.00
LC1F265/2654 or 330/330A LA9FJ4H 149.00
LC1F500 or 5004
LC1F115/150 or 1154/1504 LA9FK4F 149.00
LC1F185 or 1854 LA9FK4G 126.00
LC1F265/2654 or 330/330A LA9FK4H 149.00
LC1F400 or 4004 LA9FK4J 149.00
LC1F630, 6304 or
LC1F800
LC1F115/150 or 1154/1504 LA9FL4F 116.00
LC1F185 or 1854 LA9FL4G 126.00
LC1F265/2654 or 330/330A LA9FL4H 149.00
LC1F400 or 4004 LA9FL4J 149.00
LC1F500 or 5004 LA9FL4K 149.00
aWith identical or different numbers of poles.
bDouble mechanical interlock with 2 mechanical links and 3 power connection bars.
cDouble mechanical interlock with 2 mechanical links and 4 power connection bars.
dPower connection to be assembled by the customer, except for contactors LC1F780 and F7804.
eLower contactor must have equal or lower current rating.
LA9F•970
LA9F•976
LA9F•977
LA9F•4•
LA9FX970
L1 L2 L3
A1
A2
A1
A2
13
5135
246 246
UVW
Reversing (motors) Application
A1
A2
A1
A2
1N 1L2 2L1 2L3
1L3 1L1 2L2 2N
1357 1 357
24682468
L1 L2 L3 N
Transfer/Changeover Applications
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-16 © 2009 Schneider Electric
All Rights Reserved
Overload Relays TeSys® D and F Overload Relay Accessories
Refer to Catalog 8502CT9901
TeSys D Overload Relay Accessories
TeSys F Overload Relay Accessories
These clear plastic protective shrouds are an effective means to meet international finger-safe requirements for power
terminals. They are designed to be used with power cables that have been bolted to the terminal.
NOTE: The protection shrouds do not attach to contactors or overloads utilizing DZ2F lug kits.
Main overload selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-2, 18-3
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-45 to 18-47
TeSys T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 16-91
Table 18.46: Mounting Kits and Platesa
Description For use with overload relays: Catalog Number $ Price
Separate mounting kits for mounting to 35 mm
DIN rail or for panel mounting with screws
LRD01–35 and LR3D01–35 LAD7B10 8.70
LRD01–35 and LRD01–35
for ring tongue terminals LAD7B106 8.70
LRD15•• LAD7B105 10.40
LR2D15•• LA7D1064 8.70
LR2D25•• LA7D2064 13.10
LRD3•••, LR3D3•••, LR2D35•• LA7D3064 17.50
Mounting plates for screw mounting
at 110 mm (4.3") centers
LRD01–35, LR3D01–35, LR2D15•• DX1AP25 11.00
LR2D25•• DX1AP26 12.00
LRD3•••, LR3D3••, LR2D35•• LA7D902 16.40
aWhen using mounting plates, separate mounting kits are also required.
Table 18.47: Accessories
Description For use with Standard
Packaging Catalog Number $ Price
Pre wiring kit allows direct connection of the N.C. contact
of relay LRD01–D32 or LR3D01–D32 to the contactor
LC1D09 through D18 10 LAD7C1 8.70
LC1D25, D32 10 LAD7C2 8.70
Stop button locking device All relays except LRD01–D32, LR3D01–D32 and
LR9D 10 LA7D901 2.20
Remote stop/tripping or electrical resetcLRD01-D32, LRD3, LR3D01-D32, LR3D3 1 LAD703b43.70
All relays except LRD01–D32, LR3D01–D31 1 LA7D03b43.70
Reset by flexible cable 500 mm (19.6 in.) LRD01-D32, LRD3, LR3D3 1 LAD7305 100.00
bPart number to be completed by adding coil voltage code. For example: LAD703F.
LA7D03 Table 18.48: Control Circuit Voltages for LA7D03 and LAD703
Volts 12 24 48 110 220/230 380/400 415/440
AC 50/60 Hz JdBEFMQN
DC JBEFM
cThe time that the LA7D03 can remain energized depends on its rest time; 1 s pulse with 9 s rest time; 5 s pulse with 30 s rest time; 10 s pulse with 90 s
rest time; maximum pulse duration of 20 s with rest time of 300 s. Consumption on inrush and sealed: < 100 VA
dNot available for LRD01-D32, LR3D01-D32.
LA7D901
LA7F90•
Table 18.49: Mounting plate for overload relay
For use with relays Catalog Number $ Price
LR9F557, F563, F567, F569 and F571 LA7F901 27.30
LR9F775, F779 and F781 LA7F902 38.20
Table 18.50: Power terminal protection shrouds, single-pole
For use with relays Catalog Number $ Price
LR9F557 LA9F701 42.40
LR9F563, F5t67, F569 LA9F702 61.00
LR9F571 LA9F705 86.00
LR9F775, F779, F781 LA9F703 82.00
Table 18.51: Power terminal protection shrouds, 3-pole
For use with relays Catalog Number $ Price
LR9F557, F563, F567, F569 LA7F701 27.30
LR9F571 LA7F702 38.20
LR9F775, F779, F781 LA7F703 49.20
Table 18.52: Connection accessories (for mounting overload relays beneath reversing contactors)e
Application Set of 3 bars
Catalog Number $ Price
For relays For contactor
LR9F557, F563, F567, F569 LC1F115 LA7F401 19.70
LR9F557, F5t63 LC1F150 and F185 LA7F402 21.80
LR9F571 LC1F265 LA7F403 27.30
LR9F775, F7••79 LC1F265...F400 LA7F404 30.50
LR9F781 LC1F400 LA7F404 30.50
LR9F775, F779, F781 LC1F500 LA7F405 38.20
LR9F781 LC1F630 LA7F406 43.70
eMounting plate required.
Table 18.53: Marking accessories
Description Sold in units of: Catalog Number $ Price
Marker holder, snap-in 100 LA7D903 .03 each
LA9F70•
LA7F701
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-17
Contactors Repair Parts TeSys® D and Old D2 AC Coils
Refer to Catalog 8502CT9901
TeSys D contactors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6
TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
LX1D2
Table 18.54: For LC1D09–D32, LC1DT20–40
(TeSys D) Contactors and CAD Relays
Rated Nominal Voltage Catalog Number 50/60 Hz $ Price
12 LXD1J7
26.20
21aLXD1Z7
24 LXD1B7
32 LXD1C7
36 LXD1CC7
42 LXD1D7
26.20
48 LXD1E7
60 LXD1EE7
100 LXD1K7
110 LXD1F7
115 LXD1FE7
26.20
120 LXD1G7
127 LXD1FC7
200 LXD1L7
208 LXD1LE7
220/230 LXD1M7
26.20
230 LXD1P7
230/240 LXD1U7
277 LXD1W7
380/400 LXD1Q7
400 LXD1V7
26.20
415 LXD1N7
440 LXD1R7
480 LXD1T7
575 LXD1SC7
600 LXD1X7 26.20
690 LXD1Y7
Specifications 50/60 Hz
Average consumption
- Inrush (inductance .75)
- Sealed (inductance .3)
70 VA
7 VA
Operating range@ 60o C 80–110% of nominal @ 50 Hz,
85–110% of nominal @ 60 Hz
aVoltage for special coils fitted in contactors with serial timer modules,
with 24 V supply.
Table 18.55: For LC1D09, D12, D18—For old D2 style
contactors where the catalog number
includes the auxiliary contact
arrangement
Rated Nominal
Voltage V
Catalog
Number
50 Hz
Catalog
Number
60 Hz
Catalog
Number
50/60 Hz
$ Price
21 bLX1D2Z5 LX1D2Z6 LX1D2Z7
52.40
24 LX1D2B5 LX1D2B6 LX1D2B7
32 LX1D2C5 ——
42 LX1D2D5 LX1D2D7
48 LX1D2E5 LX1D2E6 LX1D2E7
110 LX1D2F5 LX1D2F6 LX1D2F7
52.40
120 LX1D2G6 LX1D2G7
127 LX1D2G5 ——
208 LX1D2L6
220 LX1D2M5 LX1D2M6 LX1D2M7
230 LX1D2P5 LX1D2P7
52.40
240 LX1D2U5 LX1D2U6 LX1D2U7
256 LX1D2W5 ——
277 LX1D2W6
380 LX1D2Q5 LX1D2Q6 LX1D2Q7
400 LX1D2V5 LX1D2V7
52.40
415 LX1D2N5 LX1D2N7
440 LX1D2R5 LX1D2R6 LX1D2R7
480 LX1D2T6
500 LX1D2S5 ——
575 LX1D2S6
52.40600 LX1D2X6
660 LX1D2Y5 ——
Specifications
Average
consumption
Inrush
(inductance .75)
50 Hz 60 Hz 50/60 Hz
60 VA 70 VA 70 VA at 50 or 60 Hz
Sealed
(inductance .3) 7 VA 7.5 VA 8 VA at 50 or 60 Hz
Operating range
at θ < 55oC / 131oF
80–110 % of
nominal voltage
80–110% of
nominal voltage
85–110% of
nominal voltage
Table 18.56: For LC1D25, D32—For old D2 style contactors where the catalog number includes the auxiliary
contact arrangement
Rated Nominal Voltage (V) Catalog Number 50 Hz Catalog Number 60 Hz Catalog Number 50/60 Hz $ Price
21bLX1D4Z5 LX1D4Z6 LX1D4Z7
72.00
24 LX1D4B5 LX1D4B6 LX1D4B7
32 LX1D4C5 ——
42 LX1D4D5 LX1D4D7
48 LX1D4E5 LX1D4E6 LX1D4E7
110 LX1D4F5 LX1D4F6 LX1D4F7
72.00
120 LX1D4G6 LX1D4G7
127 LX1D4G5 ——
208 LX1D4L6
220 LX1D4M5 LX1D4M6 LX1D4M7
230 LX1D4P5 LX1D4P7
72.00
240 LX1D4U5 LX1D4U6 LX1D4U7
256 LX1D4W5 ——
277 LX1D4W6
380 LX1D4Q5 LX1D4Q6 LX1D4Q7
400 LX1D4V5 LX1D4V7
72.00
415 LX1D4N5 LX1D4N7
440 LX1D4R5 LX1D4R6 LX1D4R7
480 LX1D4T6
500 LX1D4S5 ——
575 LX1D4S6
72.00600 LX1D4X6
660 LX1D4Y5 ——
Specifications
50 Hz 60 Hz 50/60 Hz
Average consumption
- Inrush (inductance .75)
- Sealed (inductance .3)
90 VA
7.5 VA
100 VA
8.5 VA
100 VA at 50 or 60 Hz
8.5 VA at 50 or 60 Hz
Operating range
at θ < 55oC / 131oF
80–110% of
nominal voltage
80–110% of
nominal voltage
85–110% of
nominal voltage
bFor use in 24 volt applications involving serial timer modules refer to page 18-10.
I12 Discount
Schedule
Limited Stock
Will be replaced with TeSys
Limited Stock
Will be replaced with TeSys
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-18 © 2009 Schneider Electric
All Rights Reserved
Contactors Repair Parts TeSys® D, Old D2, and F AC Coils
Refer to Catalog 8502CT9901
cLC1F780 contactors operate on 2 coils as a set. The LX1FX part
number includes both coils.
dThe 600 V coils for the F400, F500 and F630 do not include an auxiliary
contact for holding circuits. If required, select appropriate contacts from
page 18-8.
eAlso requires rectifier DR5TE4U for 110 V–240 V coils, DR5TE4S for
380 V–440 V coils. See table below for pricing.
fCoil circuit requires a separately mounted rectifier. Order from
Rectifier Table.
gComplete catalog number by adding suffix. For example: LX1FF024.
Application Note on Contactor Drop-out Times:
Contactors using LX1, FH, FJ, FK, FL, and FX coils have
longer drop-out times. For critical applications such as
emergency stop functions:
Select a fast drop-out coil (LX9), or
Use a maintained contact Stop button, or
Use an interposing relay.
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6
TeSys F contactors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-5, 18-7
TeSys D overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys D replacement coils. . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-17 to 18-19
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-40 to 18-47
LX1D6
Table 18.57: For old D2 style LC1D40, D50,
D65, D80
Table 18.58: For TeSys D LC1D40A, D50A,
D65A, DT60A, DT80A
Table 18.59: For TeSys D LC1D115, D150
Rated
Nominal
Voltage V
Catalog
Number
50 Hz
Catalog
Number
60 Hz
Catalog
Number
50/60 Hz
$ Price
Rated
Nominal
Voltage V
Catalog
Number
50 Hz
Catalog
Number
60 Hz
Catalog
Number
50/60 Hz
$ Price
Rated
Nominal
Voltag e V
Catalog
Number
50 Hz
Catalog
Number
60 Hz
Catalog
Number
50/60 Hz
$ Price
24 LX1D6B5 LX1D6B6 LX1D6B7 41.50 12 LXD3J5 ——41.50 24 LX1D8B5 LX1D8B6 LX1D8B7 78.00
32 LX1D6C5 ——41.50 24 LXD3B7 41.50 32 LX1D8C5 LX1D8C7 78.00
42 LX1D6D5 LX1D6D7 41.50 32 LXD3C7 41.50 42 LX1D8D5 LX1D8D7 78.00
48 LX1D6E5 LX1D6E6 LX1D6E7 41.50 42 LXD3D7 41.50 48 LX1D8E5 LX1D8E6 LX1D8E7 78.00
110 LX1D6F5 LX1D6F6 LX1D6F7 41.50 48 LXD3E7 41.50 110 LX1D8F5 LX1D8F6 LX1D8F7 78.00
120 LX1D6G6 LX1D6G7 41.50 100 LXD3K7 41.50 115 LX1D8FE5 LX1D8FE7 78.00
127 LX1D6G5 ——41.50 110 LXD3F7 41.50 120 LX1D8G6 LX1D8G7 78.00
208 LX1D6L6 LX1D6LE7 41.50 115 LXD3FE7 41.50 127 LX1D8FC5 LX1D8FC7 78.00
220 LX1D6M5 LX1D6M6 LX1D6M7 41.50 120 LXD3G7 41.50 208 LX1D8L6 LX1D8L7 78.00
230 LX1D6P5 LX1D6P7 41.50 127 LXD3FC7 41.50 220/230 LX1D8M5 LX1D8M6 LX1D8M7 78.00
240 LX1D6U5 LX1D6U6 LX1D6U7 41.50 200 LXD3L7 41.50 230 LX1D8P5 LX1D8P7 78.00
256 LX1D6W5 ——170.00 208 LXD3LE7 41.50 240 LX1D8U5 LX1D8U6 LX1D8U7 78.00
277 LX1D6W6 41.50 220 LXD3M7 41.50 277 LX1D8W6 LX1D8W7 78.00
380 LX1D6Q5 LX1D6Q6 LX1D6Q7 41.50 230 LXD3P7 41.50 380/400 LX1D8Q5 LX1D8Q6 LX1D8Q7 78.00
400 LX1D6V5 LX1D6V7 41.50 240 LXD3U7 41.50 400 LX1D8V5 LX1D8V7 78.00
415 LX1D6N5 LX1D6N7 41.50 277 LXD3W7 41.50 415 LX1D8N5 LX1D8N7 78.00
440 LX1D6R5 LX1D6R6 LX1D6R7 41.50 380 LXD3Q7 41.50 440 LX1D8R5 LX1D8R6 LX1D8R7 78.00
480 LX1D6T6 41.50 400 LXD3V7 41.50 480 LX1D8T6 LX1D8T7 78.00
500 LX1D6S5 ——170.00 415 LXD3N7 41.50 500 LX1D8S5 LX1D8S6 78.00
575 LX1D6S6 41.50 440 LXD3R7 41.50
For old style and new TeSys style contactors where the catalog
number may or may not include the auxiliary contact arrangement.
600 LX1D6X6 41.50 480 LXD3T7 41.50
660 LX1D6Y5 ——41.50 500 LXD3S7 41.50
For old style and new TeSys style contactors where the catalog
number may or may not include the auxiliary contact arrangement.
575 LXD3SC7 41.50
600 LXD3X7 41.50
660 LXD3YC7 41.50
690 LXD3Y7 41.50
Specification 50 Hz 60 Hz 50/60 Hz Specification 50 Hz 60 Hz 50/60 Hz Specification 50 Hz 60 Hz 50/60 Hz
Average consumption:
-inrush (inductance .75)
-sealed (inductance .3)
200 VA
20 VA
220 VA
22 VA
245 VA at 50 or 60 Hz
26 VA at 50 or 60 Hz
Average consumption:
-inrush (inductance .3)
-sealed (inductance .3)
160 VA
7.0 VA
140 VA
7.5 VA
140 Va (Inductance: .9)
7.5 Va (Inductance: .9)
Average consumption:
-inrush (inductance .3)
-sealed (inductance .3)
300 VA
22 VA
300 VA
22 VA
350 Va (Inductance: .9)
18 Va (Inductance: .9)
Operating range
at θ < 55oC / 131oF
80–110%
of nominal
voltage
80–110%
of nominal
voltage
85–110%
of nominal voltage
Operating range at
θ < 55oC / 131oF
85–110%
of nominal
voltage
85–110%
of nominal
voltage
80–115%
of nominal voltage
Operating range at
θ < 55oC / 131oF
85–110%
of nominal
voltage
85–110%
of nominal
voltage
80–115%
of nominal voltage
Table 18.60: For LC1F115, F150, F185, F265, F330, F400, F500, F630, F780, F800
LX1 coils are the standard coils that are included when a voltage code is added to the contactor part number. The LX9 coils may be ordered separately for special
applications. LX9 coils do not include a built-in normally open holding circuit contact; a separate auxiliary contact block with a N.O. contact should be added to the
contactor. Both the LX1 and LX9 coils can be used on the previous F-line contactors.
Device
Type Hz Catalog
Number
Catalog Number Suffixg
24 V 48 V 110 V 120 V 208 V 220 V 240 V 277 V 380 V 415 V 440 V 480 V 600 V $ Price
F115–F150
50 LX1FF024 048 110 127 200 220 240 264 380 415 415 500 600 78.00
60 LX1FF020 040 092 095 162 184 187 220 316 340 360 380 475 78.00
40–400 LX9FF 048 110 127 200 220 220 260 380 415 415 500 78.00
F185
F225
50 LX1FG024 048 110 127 200 220 240 264 380 415 415 450 600 108.00
60 LX1FG020 040 092 095 162 184 187 220 316 340 360 380 475 108.00
40–400 LX9FG 048 110 127 200 220 220 260 380 415 415 500 108.00
F265–F330 40–400 LX1FH0242 0482 1102 1272 2002 2202 2402 2772 3802 3802 4402 5002 6002 138.00
40–400 LX9FH 0482 1102 1272 2002 2202 2402 2772 3802 3802 . . . 5002 138.00
F400d40–400 LX1FJ 048 110 110 200 220 240 280 380 415 415 415 600 287.00
40–400 LX9FJ f910 917 925 925 930 931 932 932 936 936 937 937 287.00
F500d40–400 LX1FK 048 110 110 200 220 240 280 380 415 415 415 600 360.00
40–400 LX9FK f910 917 925 925 930 931 932 932 936 936 937 937 360.00
F630d40–400 LX1FL 048 110 110 200 220 240 260 380 415 415 415 600 398.00
40–400 LX9FL f910 917 924 925 930 930 931 932 935 936 936 937 483.00
F780, FX c40–400 LX1FX 110 110 200 220 220 280 380 415 415 415 — 795.00
F800 50/60 LX4F8 e FW FW MW MW QW QW QW 725.00
Table 18.61: Rectifier Table
Coil Rectifier Catalog Number $ Price
LX9F910 DR5TF4V 75.00
LX9F917 DR5TF4V 75.00
LX9F925 DR5TE4U 75.00
LX9F926 DR5TE4U 75.00
LX9F931 DR5TE4U 75.00
LX9F936 DR5TE4S 75.00
LX9F937 DR5TE4S 75.00
LX9F938 DR5TE4S 75.00
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-19
Contactors Repair Parts TeSys® D, and Old D2 DC Coils
Refer to Catalog 8502CT9901
Note: DC coils for LC1D09-D32, LC1DT20 - LC1DT40, and LCIDttA
contactors are not replaceable.
TeSys D contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-4, 18-6
TeSys D overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . .page 18-16
TeSys D replacement coils . . . . . . . . . . . . . . . . . . . . . . pages 18-17 to 18-19
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46
Table 18.62: For old D2 LP1D09, D12, D18 Contactors
ac
Rated
Nominal Voltage
V
Catalog Number Catalog Number
Wide range $ Price
12 LX4D2JD LX4D2JW 79.00
21bLX4D2ZD 79.00
24 LX4D2BD LX4D2BW 79.00
36 LX4D2CD LX4D2CW 79.00
48 LX4D2ED LX4D2EW 79.00
60 LX4D2ND 79.00
72 LX4D2SD LX4D2SW 79.00
110 LX4D2FD LX4D2FW 79.00
125 LX4D2GD 79.00
220 LX4D2MD LX4D2MW 79.00
250 LX4D2UD 79.00
440 LX4D2RD 79.00
600 LX4D2XD 79.00
Specifications
Average consumption 9 W 11 W
Operating range at
θ–55oC / 131oF
80–110% of
nominal voltage
70–125% of
nominal voltage
Table 18.63: For old D2 LP1D25, D32 ac
Rated
Nominal Voltage
V
Catalog
Number
Catalog Number
Wide range $ Price
12 LX4D4JD LX4D4JW 110.00
21 bLX4D4ZD 110.00
24 LX4D4BD LX4D4BW 110.00
36 LX4D4CD LX4D4CW 110.00
48 LX4D4ED LX4D4EW 110.00
60 LX4D4ND 110.00
72 LX4D4SD LX4D4SW 110.00
110 LX4D4FD LX4D4FW 110.00
125 LX4D4GD 110.00
220 LX4D4MD LX4D4MW 110.00
250 LX4D4UD 110.00
440 LX4D4RD 110.00
600 LX4D4XD 110.00
Specifications
Average consumption 11 W 13 W
Operating range at
θ < 55oC / 131oF
80–110% of nominal
voltage
70–125% of nominal
voltage
aFor old style contactors where the catalog number includes the auxiliary
contact arrangement (ex. LP1D2510). The new style TeSys DC
controlled contactors (ex. LC1D25BD) do not have replaceable coils.
bFor use in 24 volt applications with serial timer modules. Refer
to page 18-10.
cNo replacement DC coils for TeSys D contactors.
Specifications
Average consumption Operating range
LC1D09-D32,
LC1DT20 - LC1DT40
Inrush 5.4 w 70 - 125% @ 60oC
Sealed 5.4 w
LCIDttAInrush 19 w 75 - 125% @ 60oC
Sealed 7.4 w
Low consumption
LC1D09-D32,
LC1DT20 - LC1DT40
Inrush 2.4 w 70 - 125% @ 60oC
Sealed 2.4 w
Table 18.64: For old D2 LP1D40, D50, D65 ac
Rated
Nominal Voltage
V
Catalog
Number
Catalog Number
Wide range $ Price
12 LX4D6JD LX4D6JW
124.00
24 LX4D6BD LX4D6BW
36 LX4D6CD LX4D6CW
48 LX4D6ED LX4D6EW
60 LX4D6ND
72 LX4D6SD LX4D6SW
124.00
110 LX4D6FD LX4D6FW
125 LX4D6GD
220 LX4D6MD LX4D6MW
250 LX4D6UD
124.00440 LX4D6RD
600 LX4D6XD
Specifications
Average consumption 22 W 23 W
Operating range at
θ < 55oC /131oF
80–110%
of nominal voltage
75–120%
of nominal voltage
Table 18.65: For old D2 LP1D80 and LC1D80a
Rated
Nominal Voltage
V
Catalog Number Catalog Number
Wide Range d$ Price
12 LX4D7JD LX4D7JW
134.00
24 LX4D7BD LX4D7BW
36 LX4D7CD LX4D7CW
48 LX4D7ED LX4D7EW
60 LX4D7ND
72 LX4D7SD LX4D7SW
134.00
110 LX4D7FD LX4D7FW
125 LX4D7GD
220 LX4D7MD LX4D7MW
250 LX4D7UD
440 LX4D7RD 134.00
600 LX4D7XD
Specifications
Average consumption 22 W 23 W
Operating range
at θ < 55oC / 131oF
80–110%
nominal voltage
70–120%
nominal voltage
dWide range coils cannot be used with contactors utilizing both front and
side mount auxiliaries.
Table 18.66: For TeSys D LC1D115, 150
Rated Nominal Voltage
VCatalog Number $ Price
24 LX4D8BD
78.00
48 LX4D8ED
60 LX4D8ND
72 LX4D8SD
110 LX4D8FD
125 LX4D8GD
78.00
220 LX4D8MD
250 LX4D8UD
440 LX4D8RD
Average consumption Inrush 365 W, Sealed 5 W
Operating range at
θ < 55oC / 131oF
70%–120% of
nominal voltage
I12 Discount
Schedule
Limited Stock
Will be replaced with TeSys
Limited Stock
Will be replaced with TeSys
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-20 © 2009 Schneider Electric
All Rights Reserved
Contactors Repair Parts TeSys® F DC Coils
Refer to Catalog 8502CT9901
TeSys F DC Coils
LX4 coils are the standard coils when a voltage code is added to the part number. The LX9 coils may be ordered
separately for special applications. LX9 coils do not include a built-in normally open holding circuit contact; a separate
auxiliary contact block with a N.O. contact should be added to the contactor. Both the LX4 and LX9 coils can be used
on previous F-line devices.
TeSys F contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-5, 18-7
TeSys F overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . page 18-16
TeSys F replacement coils and parts . . . . . . . . . .pages 18-18, 18-18, 18-20
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47
Table 18.67: LX4 coils for LC1F115, F150, F185, F265, F400, F500, F630, F780, F800
Device
Type
Catalog
Number Catalog Number Suffix
24 V 36V 48 V 60 V 72 V 110 V 125 V 220 V 250 V 440 V $ Price
F115, F150 LX4FF024 035 048 060 070 110 125 220 250 440 78.00
F185, F225 LX4FG024 035 048 060 070 110 125 220 250 440 108.00
F265, F330 LX4FH024 035 048 060 070 110 125 220 250 440 138.00
F400 LX4FJ 048 060 070 110 125 220 250 440 287.00
LX9FJc 918 926 927 932 938 287.00
F500 LX4FK 048 060 070 110 125 220 250 440 360.00
LX9FKc 918 926 927 932 938 360.00
F630 LX4FL 048 060 070 110 125 220 250 440 398.00
LX9FKc 918 926 927 932 938 398.00
F780 LX4FXa— — — 110 125 220 250 440 795.00
F800 LX4F8b— — — FW FW MW QW 725.00
aLC1F780 contactors operate on 2 coils as a set. The LX4FX part number includes both coils.
bAlso requires rectifier DR5TE4U, $72.00 list price.
cCoil Circuit requires a separately mounted resistor. Order from Table 18.68 below.
Table 18.68:
Coil
Resistor
Catalog
Number
Qty.
Required $ Price Coil
Resistor
Catalog
Number
Qty.
Required $ Price Coil
Resistor
Catalog
Number
Qty.
Required $ Price
LX9FJ918 DR2SC0047 113.70 LX9FK918 DR2SC0039 113.70 LX9FL918 DR2SC0047 213.70
LX9FJ926 DR2SC0030 113.80 LX9FK926 DR2SC0220 113.70 LX9FL925 DR2SC0270 213.70
LX9FJ927 DR2SC0390 113.70 LX9FK927 DR2SC0330 113.70 LX9FL926 DR2SC0330 213.70
LX9FJ932 DR2SC1200 113.70 LX9FK932 DR2SC1000 113.70 LX9FL931 DR2SC1000 213.70
LX9FJ938 DR2SC4700 113.70 LX9FK938 DR2SC3300 113.70 LX9FL937 DR2SC3900 213.70
I12 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-21
Enclosed Starters TeSys® D in Metal Enclosures
Refer to Catalog 8502CT9901
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-48
TeSys D enclosed full voltage starters are available in Type 1 and Type 12/3R enclosures through 50 hp at 460 V. The
enclosed D-line accepts standard D-Line accessories and all Insta-Kits™ control units and control power transformer
kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure.
For extra capacity, please refer to your local distributor or nearest Square D/Schneider Electric sales office.
Table 18.69: Enclosed Full Voltage Non-reversing Starters
Max. Horsepower Ratings (AC3) Auxiliary Contacts Current Rating
of Contactor
Catalog Number $ Price Catalog Number $ Price1 Phase 3 Phase
115 230 200 V 230 V 460 V 575V N.O. N.C. Type 1 Type 12/3R
0.333 1 2 2 5 7.5 1 1 9 LE1D093A62••••• 109. LE1D093A72••••• 175.
0.5 2 3 3 7.5 10 1 1 12 LE1D123A62••••• 137. LE1D123A72••••• 202.
1 3 5 5 10 15 1 1 18 LE1D183A62••••• 153. LE1D183A72••••• 219.
2 3 5 7.5 15 20 1 1 25 LE1D253A62••••• 170. LE1D253A72••••• 235.
2 5 7.5 10 20 25 1 1 32 LE1D323A62••••• 191. LE1D323A72••••• 245.
3 5 10 10 30 30 1 1 40 LE1D403A62••••• 273. LE1D403A72••••• 393.
3 7.5 12 15 40 40 1 1 50 LE1D503A62••••• 300. LE1D503A72••••• 420.
5 10 20 20 40 50 1 1 65 LE1D653A62••••• 393. LE1D653A72••••• 514.
7.5 15 30 30 60 60 1 1 80 LE1D803A62••••• 473. LE1D803A72••••• 610.
Table 18.70: Enclosed Full Voltage Reversing Starters
Max. Horsepower Ratings (AC3) 3 Phase Auxiliary Contacts On Each
Contactor Current Rating
of Contactor
Catalog Number $ Price Catalog Number $ Price
200V 230 V 460 V 575 V N.O. N.C. Type 1 Type 12/3R
2 2 5 7.5 1 1 9 LE2D093A62••••• 305. LE2D093A72••••• 382.
3 3 7.5 10 1 1 12 LE2D123A62••••• 355. LE2D123A72••••• 453.
5 5 10 15 1 1 18 LE2D183A62••••• 385. LE2D183A72••••• 483.
5 7.5 15 20 1 1 25 LE2D253A62••••• 415. LE2D253A72••••• 513.
7.5 10 20 25 1 1 32 LE2D323A62••••• 464. LE2D323A72••••• 573.
10 10 30 30 1 1 40 LE2D403A62••••• 655. LE2D403A72••••• 819.
12 15 40 40 1 1 50 LE2D503A62••••• 710. LE2D503A72••••• 874.
20 20 40 50 1 1 65 LE2D653A62••••• 900. LE2D653A72••••• 1030.
30 30 60 60 1 1 80 LE2D803A62••••• 1248. LE2D803A72••••• 1412.
Table 18.71: Catalog Number Nomenclature
fControl Power Transformer
Add price from page 18-23. Select letter for primary
voltage of CPT:
Voltage No Transformer used 208 240 480 600
Code O aLMTX
aLetter O, not zero.
Note: If control transformer is used, the only options available are 24 or 120
volts as the secondary of the transformer. Also, DC voltages are not
available when control power transformer is used.
gContactor/Starter Coil Voltage
Select coil voltage from table:
Voltag e 24 120 208 240 480 600
AC BGLUTX
DC B —————
hCoil Frequency
Select:
7 = dual frequency coils (50/60 Hz.)
6 = 60 Hz.
D=DC
Note: For 9 to 65 A contactors, only dual frequency coils are available; 80
A contactors, the 24 V to 240 V coils are dual frequency only (50/60
Hz.). The 480 V to 600 V coils are 60 Hz. only. See catalog for other
restrictions.
jOverload relay type
Select:
0 = No overload relay
1 = Class 10 Trip
2 = Class 20 Trip
LE1D093A62 O G 7 1 07
Overload Relay Range i
Overload Relay Type j
Coil Frequency h
Contactor/Starter Coil Voltage g
Control Power Transformer f
Wiring Method
Base Catalog Number
Catalog Number Example:
iOverload Relay Range
Select code from the below:
Code Range For use on
Contactors $ Price Adder
01 0.1–0.16 D09–D32b60.
02 0.16–0.25 D09–D32b60.
03 0.25–0.40 D09–D32b60.
04 0.40–0.63 D09–D32b60.
05 0.63–1.0 D09–D32b60.
06 1.0–1.6 D09–D32b60.
07 1.6–2.5 D09–D32b60.
08 2.5–4 D09–D32 60.
10 4–6 D09–D32 60.
12 5.5–8 D09–D32 60.
13 9–13 D40, D50, D65 107.
14 7–10 D09–D32 62.
16 9–13 D12–D32 62.
18 12–18 D40, D50, D65 107.
21 12–18 D18–D32 62.
22
16–24 D25–D32b62.
17–25 D25–D32c62.
17–25 D80 107.
25 17–25 D40, D50, D65 107.
30 23-28 D25–D32c73.
32 23–32 D25–D32 73.
32 23–32 D40, D50, D65 107.
40 30–40 D40, D50, D65 107.
50 37–50 D40, D50, D65 107.
53 30–38 D80 107.
55 30–40 D80 107.
57 37–50 D80 107.
59 48–65 D80 107.
61 55–70 D65–D80 107.
63 63–80 D65–D80 107.
65 48–65 D40, D50, D65 107.
bAvailable for Class 10 only.
cAvailable for Class 20 only.
Note: If no overload relay is required, leave this portion of the catalog blank.
Add appropriate Price Adder to the base price of the starter.
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-22 © 2009 Schneider Electric
All Rights Reserved
Enclosed Combination
Starters
TeSys® D Fusible Disconnect Switch or Circuit Breaker
Refer to Catalog 8502CT9901
IEC combination starters combine the requirements of motor overload and short circuit protection in one convenient
compact package. All devices provide Type 2 Coordination through 30 hp at 460 V. Devices are available in Type 1 and
Type 12/3R enclosures. The IEC combination starter line accepts standard TeSys D accessories and all Insta-Kits
pilot devices and control power transformer kits. Standard capacity control power transformers with built-in fuse block
can be installed in the standard enclosure. For extra capacity, please refer to your local distributor or nearest
Square D/Schneider Electric sales office.
NOTE: Use tables and notes from page 18-21 to complete the catalog numbers.
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-48
Table 18.72: Enclosed full voltage non-reversing fusible combination starters
Max. Horsepower Ratings (AC3) Fuse Clip Rating Auxiliary
Contacts Current
Rating of
Contactor
Catalog Number $ Price Catalog Number $ Price3 Phase
200 V 230 V 460 V 575 V Amperes UL Class N.O. N.C. Type 1 Type 12/3R
2 2 5 7.5 30 A CC 1 1 9 LE1D096B62••••• 426. LE1D096B72••••• 551.
3 3 7.5 10 30 A CC 1 1 12 LE1D126B62••••• 468. LE1D126B72••••• 592.
5 5 10 15 30 A J 1 1 18 LE1D186B62••••• 484. LE1D186B72••••• 607.
5 7.5 15 20 30 A J 1 1 25 LE1D256B62••••• 500. LE1D256B72••••• 623.
7.5 10 20 25 60 A J 1 1 32 LE1D326C62••••• 653. LE1D326C72••••• 829.
10 10 30 30 60 A J 1 1 40 LE1D406C62••••• 708. LE1D406C72••••• 877.
Table 18.73: Enclosed full voltage reversing fusible combination starters
Max. Horsepower Ratings (AC3) Fuse Clip Rating Aux. Contacts
Each Contactor Current
Rating of
Contactor
Catalog Number $ Price Catalog Number $ Price3 Phase
200 V 230 V 460 V 575 V Amperes UL Class N.O. N.C. Type 1 Type 12/3R
2 2 5 7.5 30 A CC 1 1 9 LE2D096B62••••• 712. LE2D096B72••••• 837.
3 3 7.5 10 30 A CC 1 1 12 LE2D126B62••••• 778. LE2D126B72••••• 915.
5 5 10 15 30 A J 1 1 18 LE2D186B62••••• 808. LE2D186B72••••• 950.
5 7.5 15 20 30 A J 1 1 25 LE2D256B62••••• 833. LE2D256B72••••• 980.
7.5 10 20 25 60 A J 1 1 32 LE2D326C62••••• 1089. LE2D326C72••••• 1281.
10 10 30 30 60 A J 1 1 40 LE2D406C62••••• 1179. LE2D406C72••••• 1371.
Table 18.74: Enclosed full voltage non-reversing circuit breaker combination starters
Max. Horsepower Ratings (AC3) Auxiliary
Contacts Circuit Breaker
Maximum
Current Rating
Current
Rating of
Contactor
Catalog Number $ Price Catalog Number $ Price3 Phase
200 V 230 V 460 V 575 V N.O. N.C. Type 1 Type 12/3R
2 2 5 7.5 1 1 15 A 9 LE1D097D62••••• 569. LE1D097D72••••• 730.
3 3 7.5 10 1 1 15 A 12 LE1D127D62••••• 622. LE1D127D72••••• 789.
5 5 10 15 1 1 30 A 18 LE1D187E62••••• 647. LE1D187E72••••• 808.
5 7.5 15 20 1 1 30 A 25 LE1D257E62••••• 668. LE1D257E72••••• 834.
7.5 10 20 25 1 1 50 A 32 LE1D327F62••••• 870. LE1D327F72••••• 1088.
10 10 30 30 1 1 50 A 40 LE1D407F62••••• 944. LE1D407F72••••• 1179.
Table 18.75: Enclosed full voltage reversing circuit breaker combination starters
Max. Horsepower Ratings (AC3) Auxiliary Contacts
Each Contactor Circuit Breaker
Maximum
Current Rating
Current
Rating of
Contactor
Catalog Number $ Price Catalog Number $ Price3 Phase
200 V 230 V 460 V 575 V N.O. N.C. Type 1 Type 12/3R
2 2 5 7.5 1 1 15 A 9 LE2D097D62••••• 836. LE2D097D72••••• 972.
3 3 7.5 10 1 1 15 A 12 LE2D127D62••••• 944. LE2D127D72••••• 1096.
5 5 10 15 1 1 30 A 18 LE2D187E62••••• 1010. LE2D187E72••••• 1174.
5 7.5 15 20 1 1 30 A 25 LE2D257E62••••• 1075. LE2D257E72••••• 1251.
7.5 10 20 25 1 1 50 A 32 LE2D327F62••••• 1403. LE2D327F72••••• 1631.
10 10 30 30 1 1 50 A 40 LE2D407F62••••• 1522. LE2D407F72••••• 1770.
Table 18.76: Enclosed full voltage non-reversing non-fused combination starters
Max. Horsepower Ratings (AC3) Fuse Clip Rating Auxiliary
Contacts Current
Rating of
Contactor
Catalog Number $ Price Catalog Number $ Price3 Phase
200 V 230 V 460 V 575 V Amperes UL Class N.O. N.C. Type 1 Type 12/3R
2 2 5 7.5 30 A CC 1 1 9 LE1D096A62••••• 416. LE1D096A72••••• 541.
3 3 7.5 10 30 A CC 1 1 12 LE1D126A62••••• 458. LE1D126A72••••• 532.
5 5 10 15 30 A J 1 1 18 LE1D186A62••••• 474. LE1D186A72••••• 597.
5 7.5 15 20 30 A J 1 1 25 LE1D256A62••••• 490. LE1D256A72••••• 613.
7.5 10 20 25 60 A J 1 1 32 LE1D326A62••••• 643. LE1D326A72••••• 819.
10 10 30 30 60 A J 1 1 40 LE1D406A62••••• 698. LE1D406A72••••• 867.
Table 18.77: Enclosed full voltage reversing non-fused combination starters
Max. Horsepower Ratings (AC3) Fuse Clip Rating Aux. Contacts
Each Contactor Current
Rating of
Contactor
Catalog Number $ Price Catalog Number $ Price3 Phase
200 V 230 V 460 V 575 V Amperes UL Class N.O. N.C. Type 1 Type 12/3R
2 2 5 7.5 30 A CC 1 1 9 LE2D096A62••••• 702. LE2D096A72••••• 827.
3 3 7.5 10 30 A CC 1 1 12 LE2D126A62••••• 768. LE2D126A72••••• 905.
5 5 10 15 30 A J 1 1 18 LE2D186A62••••• 798. LE2D186A72••••• 940.
5 7.5 15 20 30 A J 1 1 25 LE2D256A62••••• 823. LE2D256A72••••• 970.
7.5 10 20 25 60 A J 1 1 32 LE2D326A62••••• 1079. LE2D326A72••••• 1271.
10 10 30 30 60 A J 1 1 40 LE2D406A62••••• 1169. LE2D406A72••••• 1361.
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-23
Enclosed Combination
Starters
Enclosure Modifications/Insta-Kits™/Overload Relay
Refer to Catalog 8502CT9901
Factory Modifications and INSTA-KITS selection
Add the Factory Modification Code to the end of the catalog number created from page
18-21. With the use of INSTA-KITS, only one operator scheme is allowed. Only the
combinations of operators and pilot lights shown below can be ordered.
Pilot lights will be at the coil voltage indicated in the catalog number for the starter.
L1 L2
PL
M
OFF ON
1234A B
OLR
95 96
X1 X2
PL
61 62 X1 X2
L1 L2
M
HAND AUTO
OFF
PL
X1 X2
34
34
95 96
61 62 PL
X1 X2
Remote by Customer Connection
L1 L2
START
STOP
12 AB
34M
95 96
1314
OLR
Start/Stop
On-Off Selector Switch
HOA Selector Switch
L1 L2 L3
M
98
97
B
A
96
95
13
14
T1 T2 T3
D-Line AC Magnetic Starter
2-3 Poll
L1 L2 L3
21
22
+
+
B
A
B
A
FR
T1 T2 T3
21
22
+
+
97
9896
95
"C"
D-Line AC Magnetic Reversing Starter
3-Pole
Table 18.78:
Description
Factory
Modification
Codea
$ Price
Insta-Kits
(for field
installation)
$ Price
Control Units Only
For-rev-stop Push Button A06L 131. LA9CA06LT 71.00
Start/Stop Push Button A06G 65. LA9CA06GT 32.80
I/O (Start/Stop) Push Button N/A N/A
I/O Push Button (double touch) A06I 83. LA9CA06IO 41.50
Emergency Stop N/A N/A
Hand-Off-Auto Selector Switch A06E 65. LA9CA06ET 32.80
On/off Selector Switch A06D 65. LA9CA06DT 41.50
Start/Mushroom Head Stop Push Button A06X 65. LA9CA06XT 63.00
Pilot Lights only
LED Pilot light, 24, 120 or 240 V A16S 134. LA9CA16STd66.00
Green-Red Pilot light, Direct supply, 24 or 120 V bA06S 112. LA9CA06STd62.00
Green-Red Transformer Pilot Light, 120, 208/240, 480
or 600 V bA06F 207. LA9CA06FTd113.00
Available combination of control units and pilot lights
Hand-Off-Auto Selector Switch w/24, 120 or 240 V
LED Pilot Light A16U 213. LA9CA16UTd177.00
Start/Stop Push Button w/ 24, 120 or 240 V LED Pilot
Light A16V 213. LA9CA16VTd177.00
On/off Selector w/ 24, 120 or 240 V LED Pilot Light A16W 213. LA9CA16WTd177.00
Start/Stop Push Button w/ Green-Red Transformer
Pilot Light A06N 177. LA9CA06NTd95.00
Start/Stop Push Button w/Green-Red Pilot Light A06V 177. LA9CA06VT 95.00
Hand-Off-Auto Selector Switch w/Green-Red Pilot
Light A06U 273. LA9CA06UT 97.00
Hand-Off-Auto Selector Switch w/Green-Red
Transformer Pilot Light A06J 273. LA9CA06JTd147.00
On/off Selector w/Green-Red Pilot Light A06W 177. LA9CA06WT 95.00
On/off Selector w/Green-Red Transformer Pilot Light A06H 273. LA9CA06HTd147.00
Control Power Transformer
Standard VA, 2 fuses in Primary, 1 Fuse in secondary A206P 260. c
50 VA extra, 2 fuses in Primary, 1 Fuse in secondary A207P 456. c
100 VA extra, 2 fuses in Primary, 1 Fuse in secondary A208P 634. c
aAdd these forms to the catalog number selected on page 18-21. The numbers as shown are for use in NEMA 1
Enclosures. For uses in NEMA 12/3R change the 6 to a 7 (ex A06U becomes A07U). Price remains the same. The
change DOES NOT apply to control power transformer forms.
bPilot lights are wired such that the light is on when the contactor is energized. For non-LED type pilot lights, a green
lens is installed on the unit when shipped. A red lens is included for use as applicable.
cSelect Insta-Kits from table below.
Table 18.79:
Total VA Insta-Kits™ Catalog Number $ Price
50 LA9TFD32d140.00
100 LA9TFD80d246.00
150 LA9TFD15d343.00
dComplete the part number for the Insta-Kits by selecting the voltage code from the appropriate tables below.
Table 18.80: Voltage Codes for pilot lights
Voltage (Vac) 24 120 208/240 480 600
Code BGMTX
Table 18.81: Voltage Codes for control power transformers
Primary Voltage 120 208 240 480 600 208 240 480 600
Secondary Voltage 24 120
Code EDCBALMTX
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-24 © 2009 Schneider Electric
All Rights Reserved
Contactors TeSys® K 3-Pole Non-Reversing Contactors
Refer to Catalog 8502CT9901
3-Pole Non-Reversing Mini-Contactors
,
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-27
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-49
LC1K0610G7
Table 18.82: AC operating coils
Maximum Horsepower Ratings Maximum Current
Type of
Connection
Auxiliary
Contacts Catalog
Number $ Price
1 Ø 3 Ø Inductive
AC3
Amperes
Resistive
AC1
Amperes
115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp N.O. N.C.
0.5 1.5 1.5 1.5 3 3 6 15 Screw-clamp
1
LC1K0610 a b 57.
1 LC1K0601 ab 57.
0.51.52355 9 20 Screw-clamp 1 LC1K0910 ab 75.
1 LC1K0901 ab 75.
0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 1 LC1K1210 ab 86.
1 LC1K1201 ab 86.
Table 18.83: Coil voltage codes for AC contactors
Up to and including 240 V coil with integral suppression device available. Add 2 to the code
required. Example J72. Price adder $10.00.
Volts AC 50/60 Hz 12 24 42 48 110 120 127 200/
208
220/
230 230 230/
240 277 380/
400
400/
415 440 480 660/
690
Code J7 B7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 UE7 Q7 N7 R7 T7 Y7
Table 18.84: DC operating coils
0.5 1.5 1.5 1.5 3 3 6 15 Screw-clamp 1 LP1K0610 ab 75.
1 LP1K0601 ab 75.
0.51.52355 9 20 Screw-clamp1 — LP1K0910 ab 92.
— 1 LP1K0901 ab 92.
0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 1 — LP1K1210 ab 106.
— 1 LP1K1201 ab 106.
Table 18.85: Coil voltage codes for DC contactors
Coil with integral suppression device available. Add 3 to the code required. Example JD3. Price
adder $10.00.
Volts DC 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250
Code JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD
Table 18.86: DC–Low consumption operating coils (devices have built-in transient suppression)
0.5 1.5 1.5 1.5 3 3 6 15 Screw-clamp 1 — LP4K0610 ab 92.
— 1 LP4K0601 ab 92.
0.51.52355 9 20 Screw-clamp1 — LP4K0910 ab 110.
— 1 LP4K0901 ab 110.
0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 1 — LP4K1210 ab 126.
— 1 LP4K1201 ab 126.
Table 18.87: Coil voltage codes for DC contactors—Low consumption
Volts DC 12 24 48 72
Code JW3 BW3 EW3 SW3
aFor TeSys K contactors with spring terminal clamps, add a “3” before the coil voltage code (ex. LC1K06103G7).
For TeSys K contactors with solder pin terminals, add a “5” before the coil voltage code (ex. LC1K09105B7).
For TeSys K contactors with slip-on terminals, add a “7” before the coil voltage code (ex. LC1K12107M7).
bComplete the catalog number with the appropriate coil voltage code. For example: LC1K0610G7.
Table 18.88: Overload relays for 3-Pole contactors with screw-clamp terminals
Class 10, Relay setting range–A Catalog Number $ Price
0.1 to 0.16 LR2K0301 59. LR2K overload relays:
AC or DC protection
Ambient compensated bimetallic
Class 10
Single phase sensitivity
Manual or auto reset
Full load current dial
0.16 to 0.23 LR2K0302 59.
0.23 to 0.36 LR2K0303 59.
0.36 to 0.54 LR2K0304 59.
0.54 to 0.8 LR2K0305 59.
0.8 to 1.2 LR2K0306 59.
1.2 to 1.8 LR2K0307 59.
1.8 to 2.6 LR2K0308 59.
2.6 to 3.7 LR2K0310 59.
3.8 to 5.5 LR2K0312 59.
5.5 to 8 LR2K0314 59.
8 to 11.5 LR2K0316 59.
10 to 14 LR2K0321 59.
LP1K0610
LP4K06105
LR2K0316
E164862
CCN NLDX
(screw terminals)
LR43364
Class 3211 04
E164862
CCN NLDX2
(slip-on &
solder-pin
terminals)
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-25
Contactors TeSys® K 3-Pole Reversing Contactors
Refer to Catalog 8502CT9901
3-Pole Reversing Mini-Contactors
Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-24
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-27
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-49
LC2K09107
LP2K0910
LP2K09105
Table 18.89: AC operating coils
Maximum Horsepower Ratings Maximum Current
Type of
Connection
Auxiliary
Contacts Catalog Number $ Price
Inductive
AC3
A
Resistive
AC1
A
115V
hp
230V
hp
200V
hp
230V
hp
460V
hp
575V
hp N.O. N.C.
0.5 1.5 1.5 1.5 3 3 6 15 Screw-clamp 1 LC2K0610 ab 130.
1 LC2K0601 ab 130.
0.51.52355920 Screw-clamp1 LC2K0910 ab 167.
1 LC2K0901 ab 167.
0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 1 LC2K1210 ab 191.
1 LC2K1201 ab 191.
Table 18.90: Coil voltage codes for AC contactors
Up to and including 240 V coil with integral suppression device available. Add 2 to the code
required. Example J72. Price adder $20.00.
Volts AC
50/60 Hz 12 24 42 48 110 120 127 200/2
08
220/
230 230 230/
240 277 380/
400
400/
415 440 480 660/
690
Code J7 B7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 UE7 Q7 N7 R7 T7 Y7
Table 18.91: DC operating coils
0.5 1.5 1.5 1.5 3 3 6 15 Screw-clamp 1 LP2K0610 ab 167.
1 LP2K0601 ab 167.
0.51.52355920 Screw-clamp1 LP2K0910 ab 202.
1 LP2K0901 ab 202.
0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 1 LP2K1210 ab 232.
1 LP2K1201 ab 232.
Table 18.92: Coil voltage codes for DC contactors
Coil with integral suppression device available. Add 3 to the code required. Example JD3. Price
adder $20.00.
Volts DC 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250
Code JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD
Table 18.93: DC–Low Consumption Operating Coils (devices have built-in transient suppression)
0.5 1.5 1.5 1.5 3 3 6 15 Screw-clamp 1 LP5K0610 ab 202.
1 LP5K0601 ab 202.
0.51.52355920 Screw-clamp1 LP5K0910 ab 238.
1 LP5K0901 ab 238.
0.51.5 3 3 7.5101220 Screw-clamp 1 LP5K1210 ab 274.
1 LP5K1201 ab 274.
Table 18.94: Coil voltage codes for DC contactors—Low consumption
Volts DC 12 24 48 72
Code JW3 BW3 EW3 SW3
aFor TeSys K contactors with spring terminal clamps, add a “3” before the coil voltage code (ex. LP2K09103BD).
For TeSys K contactors with solder pin terminals, add a “5” before the coil voltage code (ex. LP5K09105BW3).
For TeSys K contactors with slip-on terminals, add a “7” before the coil voltage code (ex. LC2K06107B7).
bComplete the catalog number with the appropriate coil voltage code. For example: LC1K0610G7.
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-26 © 2009 Schneider Electric
All Rights Reserved
Contactors TeSys® K 4-Pole Contactors
Refer to Catalog 8502CT9901
Overload Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-24
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-27
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-49
LC2K090045
Table 18.95: AC Operating Coils
Maximum Horsepower Ratings Maximum Current
Type of Connection
Power
Poles Catalog
Number $ Price
1 PH 3 PH Inductive
AC3
A
Resistive
AC1
A
115 V
hp
230 V
hp
200 V
hp
230 V
hp
460 V
hp
575 V
hp N.O. N.C.
4-Pole Mini Contactor
0.51.52355915 Screw-clamp 4 — LC1K09004 ab 75.
2 2 LC1K09008 ab 81.
0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 4 LC1K12004 ab 86.
4-Pole Mechanically Interlocked Contactors
0.51.52355920 Screw-clamp 4LC2K09004 ab 167.
0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 4 LC2K12004 ab 191.
Table 18.96: Coil voltage codes for AC contactors
Up to and including 240 V coil with integral suppression device available. Add 2 to the code
required. Example J72. Price adder $10.00 ($20.00 for mechanically interlocked contactors)
Volts AC 50/60 Hz 12 24 42 48 110 120 127 200/208 220/230 230 230/ 240 277 380/400 400/415 440 480 660/690
Code J7 B7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 UE7 Q7 N7 R7 T7 Y7
Table 18.97: DC operating coils
4-Pole Mini Contactor
0.5 1.5 2 3 5 5 9 15 Screw-clamp 4 — LP1K09004 ab 92.
2 2 LP1K09008 ab 98.
0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 4 LP1K12004 ab 106.
4-Pole Mechanically Interlocked Contactors
0.5 1.5 2 3 5 5 9 20 Screw-clamp 4 LP2K09004 ab 202.
0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 4 LP2K12004 ab 232.
Table 18.98: Coil voltage codes for DC contactors
Coil with integral suppression device available. Add 3 to the code required. Example JD3. Price
adder $10.00 ($20.00 for mechanically interlocked contactors)
Volts DC 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250
Code JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD
Table 18.99: DC–Low consumption operating coils (devices have built-in transient suppression)
4-Pole Mini Contactor
0.5 1.5 2 3 5 5 9 15 Screw-clamp 4 — LP4K09004 ab 110.
2 2 LP4K09008 ab 116.
0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 4 LP4K12004 ab 126.
4-Pole Mechanically Interlocked Contactors
0.5 1.5 2 3 5 5 9 20 Screw-clamp 4 LP5K09004
ab 238.
0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 4 LP5K12004 ab 274.
Table 18.100: Coil voltages for DC contactors—Low consumption
Volts DC 12 24 48 72
Code JW3 BW3 EW3 SW3
aFor TeSys K contactors with spring terminal clamps, add a “3” before the coil voltage code (ex. LC1K09103L7).
For TeSys K contactors with solder pin terminals, add a “5” before the coil voltage code (ex. LP4K06015JW3).
For TeSys K contactors with slip-on terminals, add a “7” before the coil voltage code (ex. LP2K090047BD).
bComplete the catalog number with the appropriate coil voltage code. For example: LC1K0610G7.
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-27
Contactors and
Accessories
TeSys® K Contactors and Accessories
Refer to Catalog 8502CT9901
LA1KN11
LA1KN22
E164862
CCN NLDX
LR43364
Class 3211 04
Table 18.101: Instantaneous auxiliary contact blocks
Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors.
Type of connection Auxiliary Contacts Catalog
Number $ Price
N.O. N.C.
Screw clamp
2— LA1KN20 14.20
—2 LA1KN02 14.20
11 LA1KN11 14.20
4— LA1KN40 a27.30
31 LA1KN31 a27.30
22 LA1KN22 a27.30
13 LA1KN13 a27.30
—4 LA1KN04 a27.30
Slip-on 1 x .250" or 2 x .110"
2— LA1KN207 14.20
—2 LA1KN027 14.20
11 LA1KN117 14.20
4— LA1KN407 a27.30
31 LA1KN317 a27.30
22 LA1KN227 a27.30
13 LA1KN137a27.30
—4 LA1KN047 a27.30
aBlock of 4 contacts cannot be used with LP4K or LP5K contactors.
LA2KT2U
Table 18.102: Electronic time delay auxiliary contact blocks
Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors.
Voltage (V) Type Timing Range
(S) Contacts Catalog
Number $ Price
24 to 48 Vac or Vdc On-delay 1 to 30 SPDT LA2KT2E 32.80
110 to 240 Vac On-delay 1 to 30 SPDT LA2KT2U 32.80
Note: Relay outputs, with single pole double throw, 240 Vac/dc, 2 A max.
Note: Maximum switching capacity 250 VA / 150 W
Note: Operating temperature: -10 to + 60°C (14 to 140°F)
Note: Reset time: 1.5 s during time delay, 0.5 after time delay
Table 18.103: Suppressor Module with incorporated LED indicator
Clip-on front mounting
Voltage range Type Sold in
lots of
Catalog
Number
$ Price
each
12 to 24 Vac and dc Varistor 5 LA4KE1B b9.80
32 to 48 Vac and dc Varistor 5 LA4KE1E b9.80
50 to 129 Vac and dc Varistor 5 LA4KE1FC b9.80
130 to 250 Vac and dc Varistor 5 LA4KE1UG b9.80
12 to 24 Vdc Diode + Zener 5 LA4KC1B c9.80
32 to 48 Vdc Diode + Zener 5 LA4KC1E c9.80
220 to 250 Vac RC 5 LA4KA1U d9.80
bProtection by limitation of the transient voltage to 2 Uc maximum. Maximum reduction of the transient voltage peaks. Slight time delay on drop-out (1.1
to 1.5 times normal).
cNo overvoltage or oscillation frequency. Polarized component. Slight time delay on drop-out (1.1 to 1.5 times normal).
dProtection by limitation of the transient voltage to 3 Uc maximum and limitation of the oscillation frequency. Slight time delay on drop-out
(1.2 times normal).
Table 18.104: Paralleling Links
Description Sold in
lots of
Catalog
Number
$ Price
each
For 2 poles with screw-clamp terminals 4 LA9E01 2.20
For 4 poles with screw-clamp terminals 2 LA9E02 3.50
Table 18.105: Power Connectors
Description Sold in
lots of
Catalog
Number
$ Price
each
Set of 6 power connections for reversing
contactors with screw-clamp terminals 100 LA9K0969 6.20
Set of 4 power connections for changeover
contactors with screw-clamp terminals 100 LA9K0970 6.20
Table 18.106: Marking strips
Description Sold in
lots of
Catalog
Number
$ Price
each
Clips onto front of the contactor 100 LA9D90 .06
Table 18.107: Accessories for overload relays
Description Type of Connection Catalog Number $ Price
Terminal block for separate clip-on mounting of the overload relay onto 35 mm
omega rail (AM1DP200) Screw-clamp LA7K0064 11.90
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-28 © 2009 Schneider Electric
All Rights Reserved
The TeSys U motor starter is integrated, simple to choose and to install, consisting of a control unit snapped in a power
base. TeSys U can be configured to fit specific applications as well. Optional accessories: reverser, current limiter,
predictive maintenance options and communication options.
To get details information about TeSys U, visit our web at www.us.schneider-electric.com/TeSysU.
Selecting TeSys U Motor Starters in Three Steps
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-29 to 18-31
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-50
Table 18.108: Step 1. Select Power Base (Only two different bases up to 32 amps.)
Control
Connection
Max. Current
(Amps)
Three Phase (HP max.) Single Phase (HP max.) Self-Protected Power Base
200/208 V 220/240 V 460 V 575/600 V 120 V 240 V Catalog
Number $ Price
With screw
terminations
12 3 3 7.5 10 1.5 2 LUB12 246.00
32 10 10 20 25 2 5 LUB32 345.00
Table 18.109: Step 2. Select Control Unit g
Setting Range
(Amps)
Standard
3-phase
Class 10 trip e
$ Price
Advanced
3-phase
Class 10 trip e
$ Price
Advanced
single-phase
Class 10 trip e
$ Price
Advanced
3-phase
Class 20 trip e
$ Price
0.15–0.6 LUCAX6•• 120.00 LUCBX6•• 150.00 LUCCX6•• 150.00 LUCDX6•• 150.00
0.3–1.4 LUCA1X•• 120.00 LUCB1X•• 150.00 LUCC1X•• 150.00 LUCD1X•• 150.00
1.25–5.0 LUCA05•• 120.00 LUCB05•• 150.00 LUCC05•• 150.00 LUCD05•• 150.00
3–12 LUCA12•• 120.00 LUCB12•• 150.00 LUCC12•• 150.00 LUCD12•• 150.00
4.5–18 fLUCA18•• 120.00 LUCB18•• 150.00 LUCC18•• 150.00 LUCD18•• 150.00
8–32 fLUCA32•• 120.00 LUCB32•• 150.00 LUCC32•• 150.00 LUCD32•• 150.00
eComplete catalog number by adding appropriate code from voltage code table below. For example: LUCAX6FU.
fControl units for 4.5–18 and 8–32 can be used ONLY with 32 amp rated power bases (LUB32 / LU2B32).
gThe control unit contains solid state overload relay and control power source for TeSys U. For more details on the different control units, their functions,
and placement on the power base, see 18-29
Table 18.110: Voltage Codes
Volts 24 48–72 110–240
DC BLh——
AC B — —
DC or AC ESiFU
hDC voltage with range of 0.90 to 1.10 of nominal.
i48–72 Vdc; 48 Vac
Table 18.111: Step 3. Select Auxiliary Contacts (optional)
Auxiliary Contact Blocks
Terminals Contact
Indicates
Contact
Normal
Status
Contact State for Each Modea
Catalog
Number $ Price
Off Ready Run
Short
Circuit
Trip
Overload
Trip
(Manual
Reset)
Overload
Trip
(Remote/
Auto
Reset)b
Screw Ready condition N.O. O I I O O I LUA1C11
34.5
Fault condition N.C. I I I O O I
Screw Ready condition N.O. O I I O O I LUA1C20
Fault condition N.O. O O O I I O
Auxiliary Contact Function Modules
Screw Pole state 2 N.O. O O I O O LUFN20
34.5Screw Pole state 1 N.O. and 1 N.C. O I O I I O O I O I LUFN11
Screw Pole state 2 N.C. 1 I O I I LUFN02
aI–indicates closed contact; O–indicates open contact
bRequires multifunction or advanced control unit plus fault differentiation module LUFDA10.
Accessory Quick Description For details & selection, see pages:
Current Limiter Increases the breaking capacity to 130kA @ 460 V 18-30
Reverser Stacked or side mounted 18-30
Line phase barrier Required for use as a self-protected combination starter (UL508E) 18-30
Multifunction Control Unit Has functions for monitoring and predictive maintenance 18-30
Function modules Fault differentiation, Thermal overload, Motor load indication 18-30
Communication modules Integrates into existing networks, major portocols are available 18-31
Soft Starter + TeSys U Use Altistart U01Soft Starter with TeSys U 18-32
Powerbus Use TeSys U with a prewired system 18-31
Configuration and connection accessories PowerSuite software, busbar, external handle 18-31
Control Unit
Function Modules
Auxiliary Contacts
+
Power Base
Te S y s ® U Motor Starter
=
1
2
3
Power Base
Control Unit
Auxiliary Contact
E164862
CCN NLDX
LR43364
Class 3211 08
Motor Starters TeSys® U Simple Motor Starter
Refer to Catalog 8502CT0201
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-29
Control Units TeSys® U Simple Motor Starter
Refer to Catalog 8502CT0201
Power Base and plug-in accessories
Find below where to install the accessories to the power base. Only one accessory can be installed in each location.
Table 18.112: Control Units and Functions
Standard Advanced Multifunction
Reference LUCA LUCB LUCC LUCD LUCM
Protection type
Class 10
Class 20
Class 5…30
Single Phase: LUCC Class 10 only
Protection functions
Short circuit
Over current
Thermal overload
Phase loss
Phase imbalance
Ground fault
Under load, long start, jam
Control functions
Manual reset
Automatic or local/remote reset
Fault differentiation
Thermal alarm
Motor load display
Fault history
Alarm Threshold adjustment
Tripping test
= built-in the control unit
= works with the related function modules (see Table 18.119 on page 30)
Control Unit or
Multifunction Control
Auxiliary
Function or Communication Module
Auxiliary Contact Block
Control Circuit
Contact Block
b Line Phase Barrier
e Reverser Unit mounts under power base
j Current Limiter attaches under power base
m Multifunction Control Unit
m
Power Base (front view)
b
ej
Side View
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-30 © 2009 Schneider Electric
All Rights Reserved
Accessories TeSys® U Simple Motor Starter
Refer to Catalog 8502CT0201
Table 18.113: Line Phase Barrier (optional) a
Description Catalog
Number $ Price
For use as a self protected combination starter, UL508E, incoming line phase barrier must be used. LU9SP0 15.00
aSee page 18-29 for placement on the power base.
Table 18.114: Reverser b
Control
Connection
Max. Current
(Amps)
Three Phase
(HP max.)
Self-Protected
Starter Base
200/208 V 220/240 V 460 V 575 V Catalog
Number $ Price
With screw terminations 12 3 3 7.5 10 LU2B12c488.00
32 10 10 20 25 LU2B32c720.00
bSee page 18-29 for placement on the power base.
cVoltage code required.
Select Control Unit Optionsef
Setting Range
(Amps)
Standard
3-phase
Class 10 trip d
$ Price
Advanced
3-phase
Class 10 trip d
$ Price
Advanced
single-phase
Class 10 trip d
$ Price
Advanced
3-phase
Class 20 trip d
$ Price
0.15–0.6 LUCAX6•• 120.00 LUCBX6•• 150.00 LUCCX6•• 150.00 LUCDX6•• 150.00
0.3–1.4 LUCA1X•• 120.00 LUCB1X•• 150.00 LUCC1X•• 150.00 LUCD1X•• 150.00
1.25–5.0 LUCA05•• 120.00 LUCB05•• 150.00 LUCC05•• 150.00 LUCD05•• 150.00
3–12 LUCA12•• 120.00 LUCB12•• 150.00 LUCC12•• 150.00 LUCD12•• 150.00
4.5–18 dLUCA18•• 120.00 LUCB18•• 150.00 LUCC18•• 150.00 LUCD18•• 150.00
8–32 dLUCA32•• 120.00 LUCB32•• 150.00 LUCC32•• 150.00 LUCD32•• 150.00
dComplete catalog number by adding appropriate code from voltage code table below. For example: LUCAX6FU.
eControl units for 4.5–18 and 8–32 can be used ONLY with 32 amp rated power bases (LUB32 / LU2B32).
fThe control unit contains solid state overload relay and control power source for TeSys U.
For more details on the different control units, their functions, and placement on the power base see page 18-29.
Table 18.115: Voltage Codes
Volts 24 48–72 110–240
DC BLgb ——
AC B — —
DC or AC ESjFU
gVoltage code to use for a power base with a communication module.
hDC voltage with range of 0.90 to 1.10 of nominal.
i48–72 Vdc; 48 Vac
Table 18.116: Current Limiter jk
Accessory Application Technical Data Mounting Catalog
Number $ Price
Current limiter/isolator Additional current limiting aspects
for the starter
130 kA at 460 V
60 kA at 575 V
Direct mounting to LUB
and LU2BLUALB1 171.00
Limiter cartridge Replacement cartridge for LUALB1 130 kA at 460 V
65 kA at 575 V LUALF1 78.00
jIncreases the breaking capacity of the motor starter.
kSee page 18-29 for placement on the power base.
Table 18.117: Control Unit Multifunction lm
Setting Range
(Amps) Multifunction programmable $ Price
0.15–0.6 LUCMX6BL
615.00
0.3–1.4 LUCM1XBL
1.25–5.0 LUCM05BL
3–12 LUCM12BL
4.5–18 LUCM18BL
8–32 LUCM32BL
lOffers motor management system capabilities. For more details see the LUCM on page 18-31.
mSee page 18-29 for placement on the power base.
Table 18.118: Function Modules no
Module Description For use with: Operation
Requirements
Catalog
Number $ Price
Fault differentiation with
manual reset
(thermal overload) Provides indication between an overload trip
and a short circuit trip. Advanced control units only 24–250 Vac or Vdc
(power from control unit)
LUFDH20 156.00
Fault differentiation with
auto reset LUFDA10 156.00
Thermal overload
pre-alarm
Signals when the motor current reaches 1.05
of the full load setting on the control unit. Advanced control units only 24–250 Vac or Vdc
(power from control unit) LUFW10 156.00
Motor load indication
Provides a signal proportional to the average
currents in the three phases divided by the full
load current setting of the control unit. The
output corresponds to a load status of 0–2
times the full load setting of the control unit.
Advanced or multi-function
control units
4–20 mA
(requires separate 24 Vdc power
supply)
LUFV2 188.00
Parallel wiring
Provides a convenient way to reduce control
wiring and allow for connecting starters to a
communications network by providing 24 Vdc
for the starters.
Advanced or multi-function
control units(24 Vdc only) and
LU9BN11C or LU9MRC pre-
wired connector
LU9G02
splitter box and PLC network LUFC00 57.00
nOffers customization for specific application requirements.
oSee page 18-29 for placement on the power base.
Line Phase Barrier
Reverser Unit assembled
under the Power Base
Current Limiter and its
Cartridge
Control Unit
Multifunction
Motor load indicator
Alarm differentiation
Parallel wiring
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-31
Accessories TeSys® U Simple Motor Starter
Refer to Catalog 8502CT0201
Configuration and Connection Accessories
\
Powerbus
Additional accessories and components are available, including:
Mounting accessories
Gateways
Cabling accessories
Magelis® remote display unit
For the complete line of TeSys U-Line motor starter accessories and all technical details (specifications,
wiring diagrams, etc.) pertaining to the product line, refer to Catalog 8502CT0201.
Table 18.119: Communication Modules de
Module Description For use with: Operation
Requirements
Catalog
Number $ Price
AS-Interface
Communication
Allows the TeSys U starter to be connected
directly to the network using AS-Interface
protocols.
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11C or LU9MRC
pre-wired connector
Requires separate 24 Vdc
power supply and AS-Interface
network
ASILUFC5 188.00
AS-Interface V2
Communication
Allows the TeSys U starter to be connected
directly to the network using AS-Interface V2
protocols.
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11C or LU9MRC
pre-wired connector
Requires separate 24 Vdc
power supply and AS-Interface
V2 network
ASILUFC51 188.00
Modbus® Communication
Protocol
Allows the TeSys U starter to be connected
directly to the network using
Modbus protocols.
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11C or LU9MRC
pre-wired connector
Requires separate 24 Vdc
power supply LULC033 218.00
Advantys™ STB
Communication
Allows the TeSys U starter to be connected to
the network using the Advantsys STB protocol
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11L or LU9MRL
pre-wired connector
Requires separate 24 Vdc
power supply LULC15 218.00
CANopen
Communication
Allows the TeSys U starter to be connected to
the network using the Can Open protocol
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11L or LU9MRL
pre-wired connector
Requires separate 24 Vdc
power supply LULC08 218.00
Beckoff Communication Allows the TeSys Ustarter to be connected to
the network using the Beckoff protocol
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11L or LU9MRL
pre-wired connector
Requires separate 24 Vdc
power supply LULC14 218.00
Profibus Communication Allows the TeSys Ustarter to be connected to
the network using the Profibus protocol
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11L or LU9MRL
pre-wired connector
Requires separate 24 Vdc
power supply LULC07 218.00
DeviceNet®
Communication
Allows the TeSys U starter to be connected to
the network using the Device Net protocol
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11L or LU9MRL
pre-wired connector
Requires separate 24 Vdc
power supply LULC09 218.00
pCommunication capabilities can be integrated into existing automation architecture via a variety of protocols.
qSee 18-29 for placement on the power base.
Table 18.120: Control Circuit Accessories f
Accessory Application Technical Data Mounting Catalog
Number $ Price
Control circuit contact block
Switches control circuit power via LUB
handle
(NEC430-74 compliance)
5 amp at 600 Vac
5 amp at 250 Vdc
Side mounting to LUB
and LU2B only LUA8E20 71.00
Through-the-door operating
mechanism
Use in enclosures 7.5 to
20 inches deep. Use with LUB only. ——LU9AP00 125.00
Operating handle (NEMA 12) Use with LU9AP00 Black / Blue Enclosure door LU9AP11 31.50
Red / Yellow Enclosure door LU9AP12 31.50
Control circuit filters Use with electronic or triac output
controllers Up to 150 VAC max. Directly to coil terminals Non-reversing LUA4F11 39.30
Reversing LUA4F12 39.30
rSee page 29 for placement on the power base.
Table 18.121: PowerSuite Configuration Software and Accessories
ItemaCatalog Number $ Priceb
PowerSuite software VW3A8104 225.00
PC connection kit VW3A8106 113.00
Pocket PC connection kit VW3A8111 143.00
aFor complete details on all components included with each item, refer to Catalog #8502CT0201.
bItems under Discount Schedule CP4C.
Table 18.122: GV2 Cabling Accessories—Bus Bars
Description Application Pitch Standard Pack Catalog Number $ Price Each
3-Pole, 63 A Bus Bar
For feeding 2 GV2 starters or TeSys U
45
54
72
1
1
1
GV2G245
GV2G254
GV2G272
23.30
23.30
23.30
For feeding 3 GV2 starters or TeSys U 45 1 GV2G345 28.70
54 1 GV2G354 28.70
For feeding 4 GV2 starters or TeSys U
45
54
72
1
1
1
GV2G445
GV2G454
GV2G472
34.20
34.20
34.20
For feeding 5 GV2 starters or TeSys U 54 1 GV2G554 34.20
AS-Interface
Modbus
DeviceNet
Profibus
CANopen
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-32 © 2009 Schneider Electric
All Rights Reserved
Soft Starters ATSU01 Altistart® Drive and TeSys® U Simple Motor Starter
Refer to Catalog 8502CT9901
Altistart Drive and TeSys U Motor Starter
ATSU01••
E231693
CCN NLDX
LR96921
Class 3211 06
Table 18.123: Soft Start/Soft Stop Unit for 0.75 to 15 kW Motors (Can be combined with the TeSys U Starter)
Motor Starter
Motor Power (1) Nominal Current Part Number $ Price230 V 460 V
HP HP A
3-Phase supply voltage: 200 ... 480 V 50/60 Hz
126ATSU01N206LT 133.00
1.5 3
259ATSU01N209LT 152.00
37.512ATSU01N212LT 175.00
510
22 ATSU01N222LT 219.00
7.5 15
10 20 32 ATSU01N232LT 300.00
aStandard motor power ratings, HP power ratings indicated according to standard UL 508.
Table 18.124: Accessories
Description Used for Starter Reference $ Price
Power connector between
ATS U 0 1N 2••LT
and TeSys U
ATS U0 1N2 ••TVW3G4104 10.00
Table 18.125: TeSys U Starter and Soft Start Unit Combinations
Motor Power
Soft Starter
TeSys U
Vol tage
Power Base Control Unit b200 V 460 V
HP HP
1 2 ATSU01N206LT
LUB 12
LUC05BL
1.5 3 ATSU01N206LT LUC12BL
2 5 ATSU01N209LT LUC12BL
3 — ATSU01N212LT LUC12BL
7.5 ATSU01N212LT LUC 18BL
5 10 ATSU01N222LT LUC18BL
7.5 15 ATSU01N222LT LUB 32 LUC32BL
10 20 ATSU01N232LT LUC32BL
bDepending on the configuration of the chosen TeSys U starter, replace the with “A” for standard, “B” for advanced, and “M” for multifunction. See
page 18-28 for a complete list of available control units. Control voltage must be 24 Vdc.
CP1G I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-33
Starters TeSys® GV2 and GV3 Manual Starter and Protector
Refer to Catalog 2520CT0001
The GV family of products are 3-pole, horsepower rated, UL 508 listed, manual starters. They include a manual
disconnect, class 10 ambient-compensated thermal overload relay, and an instantaneous magnetic trip mechanism in
one compact unit.
Any GV manual starter can be used alone for local manual control of a motor with individual full-load currents up to 220
amps. The GV family of products may also be used in group motor installations in accordance with National Electric
Code article 430-53. Group motor installations give you greater panel density for smaller size and require fewer parts
and less wiring necessary for installation when compared to conventional panel designs.
The GV2P and GV3P products also have an additional UL 508 type E rating as a stand alone self-protected manual
combination starter. The UL 508 type E rating requires the addition of line side insulating barrier GV2GH7 for the GV2P
or part number GV3G66 for the GV3P. The GV2P and the GV3P self-protected manual combination starter may also
be combined with specific size contactors from the LC1D product family for a UL 508 Type F combination starter
construction. These products have UL-listed short circuit current rating from 10–100 KA depending on application size
and voltage. See www.us.telemecanique.com for more information.
How to Order
To order the basic motor starter, select the model number (GV2ME••, GV2P••, or GV3P••) with the appropriate thermal
setting from the table below. The thermal trip range and setting should be determined from the motor nameplate full-
load current.
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-36
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-34 to 18-35
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55
GV2ME
GV3P
E164864
CCN NLRV
LR81630
Class 3211 05
GV2P21 with
GV2GH7 installed
Table 18.126:
Thermal
Setting
(A)
Maximum Horsepower Ratings Group Motor
Applications GV2/3M push button GV2/3P rotary handle
1Ø 3Ø
115 V
hp
230 V
hp
200 V
hp
230 V
hp
460 V
hp
575 V
hp
Max. Fuse or
Circuit Breaker
Catalog
Number $ Price Catalog
Number $ Price
0.110.16—————— 450 A GV2ME01a159. GV2P01 212.
0.160.25—————— 450 A GV2ME02a159. GV2P02 212.
0.250.40—————— 450 A GV2ME03a159. GV2P03 212.
0.400.63—————— 450 A GV2ME04a180. GV2P04 233.
0.631————0.50.5 450 A GV2ME05a180. GV2P05 233.
1–1.6 0.1 0.75 1 450 A GV2ME06a180. GV2P06 233.
1.6–2.5 0.667 0.5 0.5 1 1.5 450 A GV2ME07a180. GV2P07 233.
2.5–4 1/8 0.333 0.75 1 2 3 450 A GV2ME08a180. GV2P08 233.
4–6.3 1/4 0.5 1.5 1.5 3 5 450 A GV2ME10a180. GV2P10 233.
6–10 0.5 1.5 2 3 5 7.5 450 A GV2ME14a180. GV2P14 233.
9–14 0.75 2 3 3 10 10 450 A GV2ME16a224. GV2P16 278.
131813551015 450 A GV2ME20a224. GV2P20 278.
17–23 1.5 3 5 7.5 15 20 450 A GV2ME21a224. GV2P21 278.
20–25 2 3 5 7.5 15 20 450 A GV2ME22a224. GV2P22 278.
2432 2 5 10102030 450 A GV2ME32 224. GV2P32 278.
9–13 0.5 1.5 3 3 7.5 10 GV3P13 404.
12–18 0.75 2 5 5 7.5 10 GV3P18 404.
17–25 1.5 3 7.5 7.5 15 20 GV3P25 404.
23–32 2 3 10 7.5 20 25 GV3P32 404.
3040 3 5 10102530 GV3P40 504.
37–50 3 7.5 15 10 30 40 GV3P50 504.
48–65 3 10 20 15 40 50 GV3P65 504.
aFor spring terminals add 3 to the catalog number, for example, GV2ME013. GV2ME32 is not available with spring terminals.
Table 18.127:
Thermal
Setting
(A)
Maximum Horsepower Ratings
Toggle Operator
115 V
hp
230 V
hp
200 V
hp
230 V
hp
460 V
hp
575 V
hp
Standard Interrupt High Interrupt
Catalog
Number $ Price Catalog
Number $ Price
12–20 — — — 5 10 15 GV7RE20 417. GV7RS20 813.
15–25 — — — 7.5 15 20 GV7RE25 417. GV7RS25 813.
25–40 — 10 30 30 GV7RE40 417. GV7RS40 813.
30–50 — 15 30 40 GV7RE50 417. GV7RS50 813.
48–80 — 30 60 75 GV7RE80 417. GV7RS80 813.
60–100 — — — 30 75 100 GV7RE100 456. GV7RS100 891.
90–150 — — — 50 100 150 GV7RE150 502. GV7RS150 978.
132–220 — — — 75 150 200 GV7RE220 502. GV7RS220 978.
New!
GV7RE20
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-34 © 2009 Schneider Electric
All Rights Reserved
Starters Accessories TeSys® GV2 and GV3 Manual Starters and Protectors
Refer to Catalog 2520CT0001
GVAU116
Table 18.128: Voltage Trips
Only one trip or fault signaling contact can be installed per GV2/GV3 device.
Description Characteristics Voltage Frequency Catalog Numbera$ Price
Voltage trips
GV2 & GV3P
Undervoltage or
Shunt trip
(external mount,
1 block right side only)
24 V 50 Hz GVA025
81.00
60 Hz GVA026
48 V 50 Hz GVA055
60 Hz GVA056
100–110 V 50/60 Hz GVA107
110–115 V 50 Hz GVA115
60 Hz GVA116
120–127 V 50 Hz GVA125
127 V 60 Hz GVA115
200 V 50 Hz GVA207
200–220 V 60 Hz GVA207
220–240 V 50 Hz GVA225
60 Hz GVA226
380–400 V 50 Hz GVA385
60 Hz GVA386
415–440 V 50 Hz GVA415
415 V 60 Hz GVA416
440 V 60 Hz GVA385
480 V 60 Hz GVA415
500 V 50 Hz GVA505
600 V 60 Hz
aTo order an under voltage trip: replace the bullet () with a U, example: GVAU025. To order a shunt trip: replace the bullet () with an S, example:
GVAS025.
GVAE11
GVAD0101
GVAN11
Table 18.129: Auxiliary Contact Blocks
Description Mounting
Location
Max. No. of
Blocks Contact Type Sold in lots of Catalog Number $ Price
Instantaneous auxiliary contacts
GV2 + GV3P
Frontbg 1
N.O. or N.C.c1GVAE1 21.80
N.O. + N.C. 10 GVAE11e35.70
N.O. + N.O. 1 GVAE20e35.70
Left Hand Side 2 N.O. + N.C. 1 GVAN11e35.70
N.O. + N.O. 1 GVAN20e35.70
Fault signaling contact +
instantaneous auxiliary contact
GV2 + GV3P
Left Hand Sided1
N.O. (fault) + N.O. 1 GVAD1010 54.00
N.O. (fault) + N.C. 1 GVAD1001 54.00
N.C. (fault) + N.O. 1 GVAD0110 54.00
N.C. (fault) + N.C. 1 GVAD0101 54.00
Short circuit signaling contact
GV2 + GV3P Left Hand Side 1 SPDT 1 GVAM11 35.70
bMounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P.
cChoice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted.
dThe GVAD is always mounted next to the starter.
eFor spring terminals add 3 to the catalog number. Example: GVAE113
fOne trip or one fault signaling can be fitted per GV3.
gCannot be used with GV2GH7 insulator.
Table 18.130: Voltage Trips–Technical Data (GV2AU, GV2AS)
Rated Voltage–660 Vac
Model Inrush Sealed Pick-Up Voltage Drop-Out Voltage Operating Timeh
GVAU 12 VA / 8 W 3.5 VA / 1.1 W 0.8 to 1.1 0.35 to 0.7 10 to 15 ms
GVAS 14 VA / 10.5 W 5 VA / 1.6 W 0.7 to 1.1 0.2 to 0.75 10 to 15 ms
hFrom the loss of voltage at the trip terminals to the opening of the starter contacts.
Table 18.131: GV3P Accessories
Description For GV3P Catalog Number $ Price
Set of 3-pole 115 A busbars
(tap-offs: 2, pitch: 64 mm) GV3P•• GV3G264 25.00
Set of 3-pole 115 A busbars
(tap-offs: 3, pitch: 64 mm) GV3P•• GV3G364 45.00
Cover “Larger Spacing” UL 508 type E
(Only one cover required on supply side) GV3P•• GV3G66 18.00
IP 20 cover
(Two covers required per starter) GV3P•• LAD96570 12.00
Padlocking device
For use with up to 4 padlocks (not supplied)
Ø 6 mm shank maximum
GV3P••
GV3P••• GV2V03 15.00
New!
CP10 I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-35
Starters Accessories TeSys® GV7 Manual Starters and Protectors
Refer to Catalog 2520CT0001
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55
GV7AE11
Table 18.132: Auxiliary contact blocks (auxiliary contact functions depends on location inside the device)
Description Mounting Location Max. No. of Blocks Contact Type Catalog Number $ Price
Standard
Instantaneous
Inside Device
2 per device N.O. + N.C.
GV7AE11 35.70Trip Indication 1 per device N.O. + N.C.
Fault Indication 1 per device N.O. + N.C.
Low Level
Instantaneous
Inside Device
2 per device N.O. + N.C.
GV7AB11 35.70Trip Indication 1 per device N.O. + N.C.
Fault Indication 1 per device N.O. + N.C.
GV7AS055
GV7AD111
Table 18.133: Voltage Trips
Description Mounting Location Max. No. of Blocks Voltage Catalog Number $ Price
Undervoltage Trip Inside Device 1 per device
48 Vac 50 Hz GV7AU055
64.00
110–130 Vac 50/60 Hz GV7AU107
200–240 Vac 50/60 Hz GV7AU207
380–440/480 Vac 50/60 Hz GV7AU387
525 Vac 50 Hz GV7AU525
Shunt Trip Inside Device 1 per device
48 Vac 50 Hz GV7AS055
64.00
110–130 Vac 50/60 Hz GV7AS107
200–240 Vac 50/60 Hz GV7AS207
380–440/480 Vac 50/60 Hz GV7AS387
525 Vac 50 Hz GV7AS525
Fault Indication Inside Device 1 per device 24–130 GV7AD111 72.00
110–415 GV7AD112
GV7AC01
GV7AP03
GV7RE20
GV7AC021 GV7V01
Table 18.134: Wiring Accessories
Description Application Catalog Number $ Price
Box Lugs Sold in lots of 3 for GV7R20–150iGV7AC021 19.70 each
Sold in lots of 3 for GV7R220iGV7AC022 24.90 each
Phase Barriers, Bus Bars & Shrouds
Terminal Extension Kit Increases center distance between phases to 45 mm GV7AC03 46.70
Terminal Shroud Kit Covers terminal connections for touch safe protection GV7AC01 41.90
Phase Barriers Provides maximum phase separation at connection points GV7AC04 31.10
Insulating Barriers Provides insulation between connectors and backplate GV7AC05 24.90
Busbars and Covers Connect to LC1F115–185 contactor GV7AC06 46.70
Connect to LC1F225–265 contactor GV7AC07 46.70
Operating Handles and Accessories
Black rotary operating handle with black legend plate (mounts directly on device) GV7AP03 86.00
Red rotary operating handle with yellow legend plate (mounts directly on device) GV7AP04 86.00
Conversion accessory to mount device directly on panel door GV7AP05 14.00
Black rotary operating handle with black legend plate and extension kit (185–600 mm) GV7AP01 102.00
Red rotary operating handle with yellow legend plate and extension kit (185–600 mm) GV7AP02 102.00
Padlocking device for toggle handle (max. 38 mm padlocks) GV7V01 14.00
iWire size: GV7AC021—#14–3/0; GV7AC022—#14–350 kcmil.
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-36 © 2009 Schneider Electric
All Rights Reserved
Starters Accessories TeSys® Manual Starters and Protectors LS1 Fuseholders
Refer to Catalog 2502CT0001
45 mm wide (same dimensions as GV2ME)
Available with screw clamp and spring type terminals
Mounts directly to LC1D09–D32 contactors (with use of GV2AF3 or GV2AF4)
Meets application needs for fusible starter
Uses GV2AE instantaneous contact blocks to open control circuits
DIN rail mounted
LS1D30
Table 18.135:
Description Fuse Type Dimensions Use In Catalog Number $ Price
IN mm
Spring terminals, 3-pole CC, KTK-R 0.41 x 1.5 10.3 x 38 US Markets LS1D303 86.
Screw clamp terminals, 3-pole CC, KTK-R 0.41 x 1.5 10.3 x 38 US Markets LS1D30 86.
Spring terminals, 3-pole aM, gG 0.39 x 1.5 10 x 38 European Markets LS1D323 101.
Screw clamp terminals, 3-pole aM, gG 0.39 x 1.5 10 x 38 European Markets LS1D32 86.
Auxiliary main pole adder aM, gG 0.39 x 1.5 10 x 38 European Markets LA8D324a65.
aCan be mounted on left-hand or right-hand side of the 3-pole LS1D32 block.
Table 18.136: Specifications
Typ e LS1D30, LS1D303 LS1D32, LS1D323, LS1DT32
Max. voltage 600 V 3 Phase
Max. current 30 A
Conforming to standards IEC 60947-1, 60947-2, 60947-4-1, EN60204, BS4841, UL 508,
CSA 222.2 No. 14, NFC 63-650, 63-120, 79-130, VDE 0113, 0660
Product approvals UL, CSA BV
Protective treatment “TH” “TH”
Ambient air temperature
—operation
-58 to 158o F
(-50 to +70o C)
Wiring
Number of conductors and cross sectional area (c.s.a.) Max. Min.
Solid cable 2–#8 AWG (2–6 mm2) 2–#16 (2–1 mm2)
Flexible cable without cable end 2–#8 AWG (2–6 mm2) 2–#14 (2–1 mm2)
Flexible cable with cable end 2–#10 AWG (2–4 mm2) 2–#16 AWB (2–1 mm2)
Resistance to mechanical impact conforming to IEC 60947-1 §7-1-6 0.5 J
Tightening torque 15 in-lb (1.7 N•m)
Sensitivity to phase failure No
Table 18.137: Specifications
Operating Positions:
Shock resistance—30 g (conforming to IEC 600 68-2-27)
Vibration resistance—5 g (5 to 150 Hz) (IEC 600 68-2-26)
Ambient temperature:
-40 to 176oF (-40 to +80oC) for storage
-4 to 140oF (-20 to +60oC) open operation
-4 to 104oF (-20 to +40oC) enclosed operation
Rated voltage—600 V
Rated thermal current—25 A (GV2), 63 A (GV3)
Mechanical life:
GV2: 100,000 operations
Maximum operating life—25 operations per hour
Operating current of magnetic trip is approximately 13 times maximum
thermal trip (non-adjustable setting)
30
30
90
90
File LR81630
Class 3211 05
File E164864
CNN NLRV
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-37
Starters Accessories TeSys® GV2 Manual Starters and Protectors
Refer to Catalog 2520CT0001
GV2GH7
LAD31
LAD311
GV2AF3 / GV2AF4
Table 18.138: GV2 Mounting Accessories
Description Application Standard
Pack bCatalog Number $ Price Each
Common mounting plate For GV2 plus any 3-pole LC1D09 thru LC1D25 contactor.
(supplied with GV1G02 connector) 1 GK2AF01 21.60
Adapter plate For screw mounting of GV2M 10 GV2AF02 7.10
Combination block
Interconnect for GV2 plus any 3-pole LC1K or LP1K contactor 10 GV2AF01 14.00
Interconnect GV2 and LC1D09 thru D32 10 GV2AF3 3.20
Interconnect GV2 and LC1D09 thru D32 mounted on LAD31 10 GV2AF4 3.20
7.5 mm compensation plate To allow mounting of GV2M and GV2P on a common bus bar 10 GV1F03 5.40
Mounting plate For mounting GV2ME or GV2P and contactor LC1D09 thru D32 10 LAD31 6.20
10 LAD311 12.30
Table 18.139: GV2 Cabling Accessories—Bus Bars
Description Application Pitch Standard Pack bCatalog Number $ Price Each
3-Pole, 63 A Bus Bar
For feeding 2 GV2 starters
45
54
72
1
1
1
GV2G245
GV2G254
GV2G272
23.30
23.30
23.30
For feeding 3 GV2 starters 45 1 GV2G345 28.70
54 1 GV2G354 28.70
For feeding 4 GV2 starters
45
54
72
1
1
1
GV2G445
GV2G454
GV2G472
34.20
34.20
34.20
For feeding 5 GV2 starters 54 1 GV2G554 34.20
Table 18.140: GV2 Other Cabling Accessories
Description Application Standard Pack bCatalog Number $ Price Each
Terminal blocks
Top feed for use with bus bars 1 GV1G09 34.20
Bottom feed, to be used with bus bars; can be fitted with GV1L3
current limiter 1GV2G05 34.20
Protective end cover To cover unused bus bar outlets 5 GV1G10 3.60
3-pole flexible connector For connecting a GV2 to an LC1D09 thru D25 contactor 10 GV1G02 14.30
Conduit adapter (1•2" NPT) 1GV2AK1 16.20
Incoming line insulator For GV2P when used in UL 508 Type E applicationsa10 GV2GH7 15.00
aCannot be used with front-mounted auxiliary contact block.
Table 18.141: GV2 Other Accessories
Description Application Standard Pack bCatalog Number $ Price Each
Visible isolation block - GV2P Front mount, 3-pole visible isolation on incoming side of GV2P 1 GV2AK00 71.40
Current limiter - GV2M Increases interrupt capacity when attached to GV2M 1 GV1L3 117.00
Through-Door operator - GV2P For operating GV2P through enclosure door (red handle, yellow
legend plate) For NEMA 1 use. IP54 1GV2AP02 135.00
Table 18.142: GV2 Enclosures
Description Mounting Rating Catalog Number $ Price Each
Enclosures for GV2M
with or without accessories
(maximum of 1 accessory
on right and left)
Enclosures are not UL or CSA listed.
Surface mount NEMA 1, IP41
IP55
GV2MC01
GV2MC02
54.00
78.00
Flush mount NEMA 1, IP41
IP55
GV2MP01
GV2MP02
31.10
54.00
Flush mount reduced width
(max. of 1 accessory on right)
NEMA 1, IP41
IP55
GV2MP03
GV2MP04
27.90
49.70
Table 18.143: GV2 Enclosures Accessories
Description Type Standard PackbCatalog Number $ Price Each
Padlocking device for GV2M (when
padlocked, starter is automatically in Off
position)
1GV2V01 26.90
Mushroom head stop push button
(40 mm, red) c
Spring return 1 GV2K011 35.90
Latching Key release (Ronis key no. 455) 1 GV2K021 104.00
Turn to Release 1 GV2K031 52.00
Latching / Padlockable Turn to Release 1 GV2K04 117.00
Sealing kit For enclosures GV2MC01 and GV2MP01 10 GV2E01 18.00
Pilot Light (neon)
110 V Green 10 GV2SN13
26.90
110 V Red 10 GV2SN14
110 V Orange 10 GV2SN15
110 V White 10 GV2SN17
220/240 V Green 10 GV2SN23
220/240 V Red 10 GV2SN24
220/240 V Orange 10 GV2SN25
220/240 V White 10 GV2SN27
380/440 V Green 10 GV2SN33
380/440 V Red 10 GV2SN34
380/440 V Orange 10 GV2SN35
380/440 V White 10 GV2SN37
bOrders must specify multiples of quantities listed.
cSupplied with IP55 sealing kit.
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-38 © 2009 Schneider Electric
All Rights Reserved
Wiring, Communications,
and Busbar System
TeSys® Contactors and Motor Protectors with Spring Terminals
Refer to Catalog 8502CT0101
APP2R4H1
Table 18.144: Splitter Boxes
A total of up to eight starters is permissible after extensions. Use multiple quantities of the same catalog number to
create the desired line-up.
Description
Type of Control-command
Connection on
Control System Side
No. of I/O per
Starter
No. of Starters
per Unit Catalog Number $ Price
50 A power splitter box 2LAD322 52.00
4LAD324 93.00
50 A power and control splitter box
1 x HE10 8I/8O 1I/1O 4 APP2R4H1 124.00
1 x HE10 16I and 1 x HE10 8O 2I/1O 4 APP2R4H2 124.00
Via module APP1C••• a2APP2R2E 124.00
4APP2R4E 124.00
AS-i 2I/1O 2 APP2R2AS 124.00
1I/1O 4 APP2R4AS 124.00
aConnection to an APP1C••• module via APP2CX adaptor (LAD35).
LAD35
Table 18.145: Power Connection Components for One Starter
Description Kit Consists of: Catalog Number $ Price
Assembly and power connection kit One LAD31 plate for GV2ME and two LAD34 power connection modules LAD351 21.00
Reversing kit bOne set of bus bars and one mechanical interlock LAD32 20.70
bTo create a TeSys D reverser, use two LC1D contactors, one assembly and power connection kit, and one reversing kit.
LAD3B
LAD33
Table 18.146: Power Connection Accessories for One Starter
Description Max. Connection
Cross-Section Use Catalog Number $ Price
Upstream terminal block (50 A max) 16 mm2 (6 AWG) Power supply for one or two power splitter boxes LAD3B 83.00
Downstream terminal block (50 A max) 6 mm2 (10 AWG) Connection of motor cables LAD331 5.00
APP2D1•
Table 18.147: Control Connection Module for One Starter
Description D-Line
Coil Voltage
Type of Coil Control
Relay Type of Starter Catalog Number $ Price
Control connection module
(integrating contact block GVAE20)
12–240 Vac or
24–125 Vdc Electromechanical cNon-reversing APP2D1 41.40
Reversing APP2D2 72.00
24–48 Vdc Without relay dNon-reversing APP2D1D 31.10
Reversing APP2D2D 31.10
cRelay supplied mounted on the front panel of the control connection.
dThe use of TeSys D low consumption contactors is recommended.
Table 18.148: Spare or Replacement Parts
Description
Type of Control-command
Connection on Control
System Side
No. of I/O
per Starter
No. of
Starters
Sold in
Lots of Catalog Number $ Price
Plate for mounting a GV2ME manual starter 110 LAD31 6.20
110 LAD311 12.30
Power connection module 1 10 LAD341 7.50
Control-command splitter box (single, for
mounting on a power splitter box)
1 x HE10 8I/8O 1I/1O 4 1 APP2R4H3 11.30
1 x HE10 16I and 1 x HE10 8O 2I/1O 4 1 APP2R4H4 11.30
Per module APP1C••• e21APP2R2C 11.30
41APP2R4C 11.30
AS-Interface 2I/1O 2 1 APP2R2A 11.30
1I/1O 4 1 APP2R4A 11.30
Replacement electromechanical relay (for control connection module) 1 10 APP2ER 7.50
eConnection to an APP1C••• module via APP2CX adaptor (LAD35).
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-39
Busbar Accessories TeSys® AK5 Panel Busbar System
Refer to Catalog 8502CT0101
The AK5 pre-fabricated bus bar system provides a quick and easy method of mounting control devices. All components
are finger safe, UL Listed, CSA approved and CE marked. Although the AK5 system can be screw mounted onto any
type of support, it must be mounted on the AM1DL201 DIN rail when component mounting plates incorporating a tap-
off are used. When using tap-offs, the nominal operating current of the bus bar (160 Amperes @ 35o) must not be
exceeded.
AK5JB143
Table 18.149: 160 Ampere Three Phase Busbar System
Maximum number of mounting plates
Length
Catalog Number $ Price
Tap-off Standard Width Plate Extension Plate
IN mm IN mm IN mm
1.42 36 2.13 54 2.80 71 IN mm
6 4 2 13.39 344 AK5JB143 210.00
9 6 3 17.64 452 AK5JB144 266.00
12 8 4 21.85 560 AK5JB145 286.00
15 10 5 26.05 668 AK5JB146 345.00
24 16 8 38.69 992 AK5JB149 393.00
27 18 9 42.90 1100 AK5JB1410 540.00
AK5PA231
AK5PA232S
Table 18.150: Mounting Plate Tap-off
Plugs into busbar mounted on AM1DL201 DIN rail.
Width Thermal
Current Amperes Application Catalog Number $ Price
IN mm
2.13 54 25 A LUS or LUB 12 and 32 & GV2 AK5PA231 98.00
2.13 54 25 A GV2 & Contactor AK5PA232 120.00
4.25 108 25 A GV2 & Reversing Contactor AK5PA232S 206.00
AK5PC33
Table 18.151: Bus Tap-off
Plugs into busbar for wiring to a separately mounted device.
Width Thermal
Current Amperes
Length of
Leads Catalog Number $ Price
IN mm IN mm
1.42 36 32 A 9.84 250 AK5 PC33 23.00
1.42 36 32 A 39.37 1000 AK5 PC33L 37.80
Table 18.152: Extension Plates
Used to mount wider components. Bolt to standard mounting plates
(after DIN rails are removed).
Width
Application Catalog Number $ Price
IN mm
2.80 71 GV & Reversing contactor AK5PE27 26.30
Table 18.153: Mounting Rail
Must be used for mounting plates with tap-offs.
Description
Depth Length Catalog
Number $ Price
mm mm
75 mm Omega Rail 15 2000 AM1DL201 41.10
Table 18.154: Approvals: IEC 439, UL, CSA, DNV, LROS
File E161251
CCN NMTR
File LR 89150
Class 6228-01
AM1DL201
I11 Discount
Schedule
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-40 © 2009 Schneider Electric
All Rights Reserved
Dimensions TeSys® D Contactors, AC Coil
Refer to Catalog 8502CT9901
Table 18.155: TeSys D Contactors AC Control Circuits
LC1D09 to D18 (3-pole) and LC1DT12 to LC1DT40 (4 pole) LC1D25 to D38 (3-pole)
LC1 D09 to D18 D093 to D18 D099 to D189 D25 to D38 D183 and D323 DT20 and DT25DT203 and DT253 DT32 to DT40 DT323 and DT403
IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm)
bAC coil, without add-on accessories 3.03 (77) 3.89 (99) 3.14 (80) 3.36 (85) 3.89 (99) 3.34 (85) 3.89 (99) 3.58 (91) 4.13 (105)
DC coil
b1
AC coil, with LAD4BB b3.70 (94) 4.21 (107) 3.75 (95.5) 3.85 (98) 4.21 (107) 3.85 (98)
AC coil, with LA4D*2 b4.33 (110) a4.84 (123) a4.30 (111.5) a4.48 (114) a4.84 (123) a4.48 (114)
AC coil, with LA4DF, DT b4.68 (119) a5.19 (132) a4.76 (120.5) a4.84 (123) a5.19 (132) a5.02 (129)
AC coil, with LA4DR, DW, DL b4.96 (126) a5.67 (139) a5.0 (127.5) a5.11 (130) a5.47 (139) a7.48 (190)
c
AC coil, without cover or add-on blocks 3.30 (84) 3.30 (84) 3.30 (84) 3.54 (90) 3.54 (90) 3.54 (90) 3.54 (90) 3.85 (98) 3.85 (98)
AC coil, with cover, without add-on blocks 3.38 (86) 3.38 (86) 3.38 (86) 3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.93 (100) 3.93 (100)
DC coil, without cover or add-on blocks 3.66 (93) 3.66 (93) 3.66 (93) 3.89 (99) 3.89 (99)
DC coil, with cover, without add-on blocks 3.76 (95) 3.76 (95) 3.76 (95) 3.97 (101) 3.97 (101) 3.90 (99) 3.90 (99) 4.21 (107) 4.21 (107)
c1 AC coil, with LADN or C (two or four contacts) 4.60 (117) 4.60 (117) 4.60 (117) 4.84 (123) 4.84 (123) 4.84 (123) 4.84 (123) 5.15 (131) 5.15 (131)
DC coil, with LADN or C (two or four contacts) 4.96 (126) 4.96 (126) 4.96 (126) 5.19 (132) 5.19 (132) 4.84 (123) 4.84 (123) 5.15 (131) 5.15 (131)
c2 AC coil, with LAD6K10 5.07 (129) 5.07 (129) 5.07 (129) 5.31 (135) 5.31 (135) 5.31 (135) 5.31 (135) 5.62 (143) 5.62 (143)
DC coil, with LAD6K10 5.43 (138) 5.43 (138) 5.43 (138) 5.66 (144) 5.66 (144) 5.31 (135) 5.31 (135) 5.62 (143) 5.62 (143)
c3
AC coil, with LADT,R,S 5.39 (137) 5.39 (137) 5.39 (137) 5.62 (143) 5.62 (143) 5.62 (143) 5.62 (143) 5.94 (151) 5.94 (151)
AC coil, with LADT,R,S and sealing cover 5.55 (141) 5.55 (141) 5.55 (141) 5.78 (147) 5.78 (147) 5.78 (147) 5.78 (147) 6.10 (155) 6.10 (155)
DC coil with LADT,R,S 5.76 (146) 5.76 (146) 5.76 (146) 5.98 (152) 5.98 (152) 5.62 (143) 5.62 (143) 5.94 (151) 5.94 (151)
DC coil with LADT,R,S and sealing cover 5.90 (150) 5.76 (146) 5.76 (146) 6.14 (156) 6.14 (156) 5.78 (147) 5.78 (147) 6.10 (155) 6.10 (155)
aIncluding LAD4BB
bNot applicable to devices with DC coils
Table 18.156: AC Coil
LC1D40, D50, D65 (3P), LC1D65004 (4P) LC1D80004 (4P)
LC1 D40A…D65A (3P), LC1 DT60A…DT80A (4P) AC OR DC LC1 D40A…D65A DT60A…DT80A D40008
IN (mm) IN (mm) IN (mm)
a 2.17 (55) 2.76 (70) 3.35 (85)
b1
with LA4 D2 5.31 (135)
with LA4 DB3 or LAD 4BB3 5.35 (136)
with LA4 DF, DT 6.18 (157) 5.59 (142)
with LA4 DM, DW, DL 6.54 (166) 5.91 (150)
cwithout cover or add-on blocks 4.65 (118) 4.65 (118) 4.92 (125)
with cover, without add-on blocks 4.72 (120) 4.72 (120)
c1 with LAD N (1 contact) 5.47 (139)
with LAD N or C (2 or 4 contacts) 5.91 (150) 5.91 (150) 5.79 (147)
c2 with LAD 6K10 or LA6 DK 6.42 (163) 6.42 (163) 6.26 (159)
c3 with LAD T, R, S 6.73 (171) 6.73 (171) 6.57 (167)
with LAD T, R, S and sealing cover 6.89 (175) 6.89 (175) 6.73 (171)
b
c
c1
c2
c3
1.77
(LAD8)
b1
1.73
LA4
.39
10
44
45
.51
13
Minimum electrical clearance
b
c
c1
c2
c3
.39
10
Minimum electrical clearance
AC Coil DC Coil
b
1.77
c
.39
10 c1
c2
c3
45
Minimum electrical clearance
b
c
.39
10 c1
c2
c3
Minimum electrical clearance
x
cept LA1DN10, DN01 = 136
+4 mm with lead sealing device
(LA2, LA3, LA6 DK1)
5.75*
146
(LA1)
6.50**
165
4.49
114
5.00
127
5.20
1325.59
142
(LA4 DF, DT)
5.91
150
(LA4 DM, DR, DW, DZ)
2.95
75
.51
13
.51
13
(LA8)(LA8)
(LA4 DA2, DE2)
(3P) 3.34
85
(4P)
(LA2, LA3, LA6 DK2)
6.02*
153
(LA1)
6.77**
172
4.92
125
5.00
127
*except LA1DN10, DN01 = 136
** +4 mm with lead sealing device
5.51
140 5.79
147
(LA4 DF, DT)
6.18
157
(LA4 DM, DR, DW, DZ)
(LA4 DA2, DE2)
3.34
85
.51
13
(LA8)
.51
13
(LA8)
(3P) 3.78
96
(4P)
4.61
117
4.80
122
a
(LAD 8N) (LAD 8N)
0.49
12.5
c1
c2
c3
b1
0.47
12
c
0.49
12.5
Minimum electrical clearance
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-41
Dimensions TeSys® D Contactors, DC Coil
Refer to Catalog 8502CT9901
Table 18.157: DC Coil
LC1D40, D50, D65 (3P), LC1D650004, (4P) LC1D80 (3P), LC1D800004(4P)
LC1D115, D150
Panel mounted with 1/4” screws
LC1 D115 D1156 D150 D1506
c 5.12 (132) 4.53 (115) 5.12 (132) 4.53 (115)
G (3-poles) 3.78/4.33 (96/110) 3.78/4.33 (96/110) 3.78/4.33 (96/110) 3.78/4.33 (96/110)
G (4-poles) 5.12/5.67 (130/144) 5.12/5.67 (130/144)
LC1D115, D150
LC1 C A
D115, D150 5.12 (132) 4.72 (120)
D115004 5.12 (132) 6.10 (155)
D1156, D1506 4.53 (115) 4.72 (120)
D1150046 4.53 (115) 6.10 (155)
LR2D4 bimetallic overload relay
Direct mounting beneath contactors
LC1D115 and D150
LR9D solid-state overload relay
Direct mounting beneath contactors
LC1D115 and D150
35 mm DIN rail dimensions 35 mm DIN rail dimensions
AM1DP200 and DR200 AM1DE••• and ED••• AM1DP200 and DR200 AM1DE••• and ED•••
d 0.10 (2.5) .41 (10.5) d 0.10 (2.5) .41 (10.5)
Note: All dimensions are in Inches (mm).
2.95(3P) 3.34(4P)
75 85
5.20 (LA4 DC3)
132
5.47 (LA4 DF, DT)
139
5.75 (LA4 DM, DR, DW, DZ)
146
.47
12 6.73
171
4.96
126
8.03* (LA1)
204
8.78d (LA6 DK2, LA2, LA3)
223
*except LA1DN10, DN01 = 136
d + 4 mm with lead sealing device
Minimum electrical clearance
8.27
*
(LA1)
210
9.02
d
(LA6 DK3, LA2, LA3)
223
4.96
126
7.13
181
.47
12
*except LA1DN10, DN01 = 143
d + 4 mm with lead sealing device
3.34 (3P) 3.78(4P)
8596
5.51 (LA4 DC3)
140
5.79 (LA4 DF, DT)
1476.06 (LA4 DM, DR, DW, DZ)
154
Minimum electrical clearance
130
5.12 ==
158
6.22
cG= =
6.22
158
c a
5.91q (LA1)
150 6.10 (LA6-DK20)
155
6.61c (LA2, LA3)
168
6.85 (LA4D•2, D•3)
174
7.28 (DF, DT)
185
7.40 (DM, DR, DW, DL)
188
LA8
LA4
aWith 2 or 4 contacts.
b+ 4 mm with sealing cover.
5.20
132
d4.72
120
10.51
267
5.91
150
7.44
189
5.20
132
4.72
120
d
6.85
174
10.04
255
5.35
136
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-42 © 2009 Schneider Electric
All Rights Reserved
Dimensions TeSys® F Contactors
Refer to Catalog 8502CT9901
LC1F115 to F330
LC1F400 to F500
All dimensions shown in mm.
To convert to inches divide by 25.4.
L
c
b
b2
==
X1 (see table 18.158)
a
aProtective cover Type
LA9F70.
Ss1
QP P Q1
af
M
c
Z
==G1
GY
J
J1
b1 ==
Table 18.158:
LC1
F115 F150 F185 F265 F330
3-Pole 4-
Pole
3-
Pole 4-Pole 3-
Pole
4-
Pole
3-
Pole
4-
Pole
3-
Pole
4-
Pole
a 163.5 200.5 163.5 200.5 168.5 208.5 201.5 243.5 213 261
b 162 162 170 170 174 174 203 203 206 206
b1 137 137 137 137 137 137 145 145 145 145
b2 265 265 301 301 305 305 370 370 375 375
c165b165b165b165b176 176 207 207 219 219
f 131 131 131 131 130 130 147 147 147 147
G 106 143 106 143 111 151 142 190 154.5 202.5
G1 80 80 80 80 80 80 96 96 96 96
J 106 106 106 106 106 106 106 106 106 106
J1 120 120 120 120 120 120 120 120 120 120
L 107 107 107 107 113.5 113.5 141 141 145 145
M 147 147 150 150 154 154 178 178 181 181
P 373740 40 404048484848
Q29.529.526.526292939344343
Q1 60 60 57.5 55.5 59.5 59.5 66.5 66.5 74 74
S 15 1520 20 202025252525
S1 27 27 34 34 34 34 38 38 44.5 44.5
Y 44 4444 44 444438383838
Z 13.5 13.5 13.5 13.5 13.5 13.5 21.5 21.5 20.5 20.5
b+6 mm with time delay block (for F115 and F150).
cOptimal terminal shroud
Note: f = minimum distance required for coil removal.
Table 18.159:
Voltage in V 220/380 415/440 500 660 1000
LC1F115, F150 20 25 30 40 20
LC1F1852025304030
LC1F2652025405040
LC1F3302535405050
Note: X1: Minimum clearance according to the operational voltage and the
breaking capacity.
2.20
56
X1
c
L
8.23
209
b
b2
==
e
(see table 18.160)
S1.49
38
M10 X 30 dia.
QPP
Q1
af
M
8 X 8.5 dia.
G
.92
23.5
G1 J
4.7
120
7.09
180
=
=
=
=
Dual Dimensions: INCHES
Millimeters
Table 18.160:
LC1 F400 F500
2-Pole 3-Pole 4-Pole 2-Pole 3-Pole 4-Pole
a 213 213 261 233 233 288
b 206 206 206 238 238 238
b2 375 375 375 400 400 400
c 213 213 213 226 226 226
f 119 119 119 141 141 141
Gd80 80 80 80 80 140
G min. 66 66 66 66 66 66
G max. 102 102 150 120 120 175
G1d170 170 170 170 170 230
G1 min. 156 156 156 156 156 156
G1 max. 192 192 240 210 210 265
dSupplied
J 19.5 19.5 67.5 39.5 39.5 34.5
L 145 145 145 146 146 146
M 181 181 181 208 208 208
P4848 48 55 55 55
Q6943 43 76 46 46
Q1 96 74 74 102 77 77
S2525 25 30 30 30
eProtective cover.
Note: f = Minimum distance required for coil removal.
Table 18.161:
Voltage in V 220/230 415/440 500 660 1000
LC1F400 30 40 40 50 60
LC1F500 40 45 50 60 60
Note: X1: Minimum clearance according to the operational voltage and the
breaking capacity.
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-43
LC1F630 and LC1F800
LC1F780, F7804
LC1F780 mounting LC1F7804 mounting
18.28
464
11.97
304
11.02
280
2.83
72
X1
9.84
250
6.10
155
7.76
197
==
c
10.39
264
1.57
40
2.52
64 6 x M12 x 45
a
QQ1
3.15
80
3.15
80
7.13*
181
2.38
60
GJ1
7.09
180
=
=
4 x Dia. 10.5 mm
Dual Dimensions: INCHES
Millimeters
LC1F630
a G supplied G min. G max. J1 Q Q1
IN mm IN mm IN mm IN mm IN mm IN mm IN mm
* = minimum distance
required for coil
removal.
c Protective terminal
cover.
2 P 12.17 309 7.09 180 3.94 100 7.68 195 2.70 68.5 4.02 102 5.00 127
3 P 12.17 309 7.09 180 3.94 100 7.68 195 2.70 68.5 2.36 60 3.50 89
4 P 15.31 389 9.45 240 5.91 150 10.83 275 2.70 68.5 2.36 60 3.50 89
X1:Minimum clearance according to the
operational voltage and the breaking capacity.
Voltage in V 380 415/440 500 660 1000
X1 in mm 60 60 60 70 80
9.84
250
6.50
165
X1
11.02
280
17.08
434
=
=
2.36
60
12 x M14 x 45
1.02
26
7.52
191
6.30
160
6.30
160
7.52
191
1.02
26
.86
22
13.70
348
15.74
400
27.64f
702
33.93a
862
7.20*
183
7.20*
183
X1: Minimum clearance according to the operational voltage and the breaking
capacity.
Voltage in V 380 415/440 660 1000
X1 in mm 90 100 120 120
f Overall length (3 poles)
a Overall length (4 poles)
*minimum distance required for coil removal.
3.50
90
9.45
240
9.45
240
5.20
132
5.00
127
7.09
180
5.00
127
6 x Dia. 10.5 mm
3.50
90
9.45
240
7.48
190
9.45
240
5.00
127
7.09
180
5.00
127
8 x Dia. 10.5 mm
4.00
102
Dimensions TeSys® F Contactors
Refer to Catalog 8502CT9901
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-44 © 2009 Schneider Electric
All Rights Reserved
Dimensions TeSys® D Reversing Contactors
Refer to Catalog 8502CT9901
LC2D09 to D32
LC2DT20 to DT60
2 x LC1DT20 to DT60
2 x LP1D40, D65, D80, D95
LC2 or 2 x LC1 abcG LC2 or 2 x LC1 abce1e2GG1
IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm)
DT20 and DT25 3.54 (90) 3.34 (85) 3.54 (90) 3.14 (80) D40 to D65 7.16 (182) 5.0 (127) 7.4 (190) 1.19 (5) 0.43 (11) 2.2 (57) 3.8 (97)
DT32 to DT60 3.54 (90) 3.58 (91) 3.85 (98) 3.14 (80) D80 and D95 8.14 (207) 5.0 (127) 8.4 (215) 0.51 (13) 0.78 (20) 3.7 (96) 4.3 (111)
c, e2: includes cabling. c, e1 and e2: includes cabling.
LC2D115 and D150
2 x LC1D115 and D150
Panel mounted with 1/4” screw
LC2 or 2 x LC1 (3-pole) a c e1 e2 G
D115, D150 266 148 56 18 242/256
LC2 or 2 x LC1 (4-pole) a c e1 e2 G
D115 334 148 60 310/324
c, e1 and e2 includes cabling
NOTE: For dimensions of TeSys F reversing contactors, please refer to Catalog 8502CT9901.
2xM0.16
G
a
==
2.36 2.76
==
c
b
e2
60 70
2xM4
c
be1e2
G1= =
6xØ6.5
1.57
a
==
G 1.57
100
6xØ0.26
8
.31
13
.51
40 40
3.94
110
4.33
6.22
158
e1e2
c
G
a
==
5.12
130
==
Dimensions shown in millimeters
(mm ÷ 25.4 = inches)
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-45
Dimensions TeSys® D Overload Relays
Refer to Catalog 8502CT9901
LRD-01-35
Independent mounting on 50 mm centers or on rail AM1DP200 or DE200
Independent mounting on 110 mm centers
Remote tripping or electrical reset
LRD, LR2D and LR9D
“Reset” by flexible cable LA7D305 and LAD7305
Mounting with cable straight Mounting with cable bent
aCan only be mounted on RH side of relay LRD-01 to 35 c: up to 21.6in (550 mm)
e: up to 0.79in (20 mm)
LRD3tt
Beneath LC1DttA contactor Separate mounting
LR2D1, LR3D1
Separate mounting at 50 mm (1.97”) centers or on AM1DP200 or DE200 rail LR2D2, LR3D2
Separate mounting at 50 mm (1.97”) centers or on AM1DP200 or DE200 rail
LR2D1, LR3D1
Separate mounting at 110 mm (4.33”) centers
LR2D2, LR3D2
Separate mounting at 110 mm (4.33”) centers
1.77
45
.08
2
3.15
80
1.50
38 3.15
80
1.97
50
.20
5
LAD7B106
1.38
35
.39
10
.24
6
.59
15
LAD7B106
4.33
110
==
1.81
46 ==
2xØ0.26
2xØ6.5
DX1AP25
3.54
90
4.92
125
LAD703 a
1.26
32
ceM10x0.04
e
M10x1
185
7.28
55
2.17
123
4.84
LC1D
pp
A
116
4.57
87
3.43
55
2.17
3.86
98
1.48
43.5
d
3.11
79
LA7-D1064
0.16
4
1.97/2.56
50/65
0.31
80.67
17
2x
Ø0.18
2xØ4.5
1.38
35
==
1.77
45
3.86
98
1.71
43.5
d
3.54
90
LA7-D2064
0.12
3
0.51
13
0.87
22
2xØ0.18
2xØ4.5
1.57
40
==
2.17
55
1.97/2.56
50/65
4.92
125
4.25
108
LA7D1064
DX1AP25
==
1.97
50
4.33
110 =
=
1.81
46
2 x Ø6.5 mm
Screws
Mounting
Holes
4.25
108
4.92
125
LA7D2064
1.97
50
4.33
110 =
=
==
2.24
57
DX1AP25
Mounting
Holes
2 x Ø6.5 mm
Screws
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-46 © 2009 Schneider Electric
All Rights Reserved
Dimensions TeSys® D Thermal Overload Relays
Refer to Catalog 8502CT9901
LRD-01-35
Direct mounting beneath contactors with screw
LRD-013-353
Direct mounting beneath contactors with spring terminal connections
LC1 D09–D18 D25–D38 LC1D093–383
b 4.84 (123) 5.39 (137) b 4.84 (123)
cSee Catalog 8502CT9901
pages 122, 123. cSee Catalog 8502CT9901
pages 122, 123.
LRD-3•••
Direct mounting beneath contactors
LC1-D40 to D95 and LP1-D40 to D80
AM1DL201 DL200
d 0.28 (7) 0.67 (17)
bceg(3P)g(4P)
AC Control Circuit
LC1D40 4.37 (111) 4.69 (119) 2.85 (72.4) 0.18 (4.5) 0.51 (13)
LC1D50 4.37 (111) 4.69 (119) 2.85 (72.4) 0.18 (4.5)
LC1D65 4.37 (111) 4.69 (119) 2.85 (72.4) 0.18 (4.5) 0.51 (13)
LC1D80 4.55 (115.5) 4.88 (124) 3.03 (76.9) 0.37 (9.5) 0.87 (22)
LC1D95 4.55 (115.5) 4.88 (124) 3.03 (76.9) 0.37 (9.5)
DC Control Circuit
LC1D40, LP1D40 4.37 (111) 6.93 (176) 2.85 (72.4) 0.18 (4.5) 0.51(13)
LC1D50 4.37 (111) 6.93 (176) 2.85 (72.4) 0.18 (4.5)
LC1D65, LP1D65 4.37 (111) 6.93 (176) 2.85 (72.4) 0.18 (4.5) 0.51(13)
LC1D80, D95, LP1D80 4.55 (115.5) 7.06 (179.4) 3.03 (76.9) 0.37 (9.5) 0.87(22)
LRD4•••
Direct mounting beneath contactors
LC1D115 and D150
LR9D
Direct mounting beneath contactors
LC1D115 and D150
AM1DL200 and DR200 AM1DE200 and ED••• AM1DP200 and DR200 AM1DE200 and ED•••
d 0.10 (2.5) 0.41 (10.5) d 0.10 (2.5) 0.41 (10.5)
aFor Additional characteristics and Catalog Number information, see Catalog 8502CT9901
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-47
Dimensions TeSys® F Overload Relays
Refer to Catalog 8502CT9901
LR9F571 LR9F557, F563, F567, F569
Common side view
aTerminal shroud LA9F70
b6.5 x 13.5 for LR9F557 and 8.5 x 13.5 for LR9F563, F567, F569
LR9F775, F779, F781 LR9F781
Common side view (for mounting beneath LC1F630)
P1 P2
LR9F775 48 48
LR9F779, F781 55 55
cTerminal shroud LA9-F70
Direct mounting beneath contactor LC1-F Direct mounting beneath reversing contactors or star-delta contactors
2.99
76
1.57
40
1.57
40
3.78
96
1.97
50
1.97
50
2.36
60
2.80
71
.22
6
4xØ5.5
4.53
115
.79
20
c
b
4.72
120
2.36
60
1.97
50
1.97
50
2.80
71
Ø11
4xØ5.5
2.24
57
1.85
47
1.77
45
1.89
48
1.89
48
.98
25
4.53
115
.22
6
.11
3
.11
3
3.98
101
2.99
76
4.88
124
q
a
4.29
109
.55
14
1.18
30
P2 P1
5.94
151
Ø11
2.05
52
2.05
52
2.60
66
2.60
66
4xØ5.5
2.76
70
.87
22
.24
6
3.23
82 5.39
137
.98
25
1.65
42
5.04
128
.24
6
1.77
45
f
c
7.44
189
.79
20
7.87
200
3.15
80
3.15
80
7.60
193
9.02
229
3.03
77
3.03
77
2.44
62
Ø13
1.57
40
1.57
40
H2
b
H3H1
d
H2
b
H4 H3
LA7F40p
Bus Bar
d
LA7F40 e
Bus bar
LC1 contactors With LR9 relays b H1 H2 H3 LC1 contactors With LR9 relays b H4 H2 H3
F115 F557, F563, F567, F569 240 30 76 120 F115 F557, F563, F567, F569 27960 76120
F150 F557, F563, F567, F569 246 30 76 120 F150 F557, F563, F567, F569 28360 76120
F185 F557, F563, F567, F569 250 30 76 120 F185 F557, F563, F567, F569 28560 76120
F225 F571 273 40 76 120 F225 F571 31980 76120
F775, F779 308 50 108.8 120 F775, F779 360 100 108.8 120
F265 F571 279 40 76 120 F265 F571 33290 76120
F775, F779 314 60 108.8 120 F775, F779 363 100 108.8 120
F330 F775, F779 317 60 108.8 120 F330 F775, F779 364 100 108.8 120
F400 F775, F779, F781 317 60 108.8 180 F400 F775, F779, F781 364 100 108.8 180
F500 F775, F779, F781 346 70 108.8 180 F500 F775, F779, F781 390 110 108.8 180
F630 F781 510 110 108.8 180 F630 F781 509 120 108.8 180
dRelay mounting plate, see page 18-16.
eConnection Accessories, see page 18-16.
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-48 © 2009 Schneider Electric
All Rights Reserved
Dimensions TeSys® D Combination and Non-combination Starters
Refer to Catalog 8502CT9901
NEMA 1
NEMA 12/3R
Non-combination Starter Dimensions
Table 18.162: Non-combination Starter Dimensions
TYPE 1 TYPE 12/3R
Non-reversing Reversing A B C D E F G H J K D E
D09-32 6.77 10.04 6.25 5.38 9.00 1–1.25 0.5–0.75 1–0.25 0.5–0.75 5.38 11.37
D40-65 D09-32 8.66 10.83 7.21 7.25 9.75 1.25–1.5 0.5–0.75 1–1.25 1–0.25 0.5–0.75 5.38 12.15
D80 D40-80 10.63 13.98 7.21 9.22 12.94 1.25–1.5 0.5–0.75 1–1.25 1–1.25 0.5–0.75 5.38 15.30
Note: All dimensions in inches.
7.50
191
Provision for 1/4" Screw
.69
18
8.00
203
3.00
76
14.02
356
12.52
318
5.00
127
16.50
419
7.50
191
Provision for 1/4" Screw
10.00
254
18.00
457
R
R
D09-25 (FVNR) D09-40 (FVR); D32-40 (FVNR)
7.75
197
Provision for 1/4" Screw
19.63
499
5.00
127
Provision for 1/4" Screw
18.88
480
7.75
197
18.00
457
14.00
356
15.63
397
14.88
378
8.00
203
3.00
76
10.00
254
R
R
D09-25 (FVNR) D09-40 (FVR); D32-40 (FVNR)
R
.56
14
D
D/2 Provision for 1/4" Screw
C.75
19
FGH
B
E
A
.50
13
J
K
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-49
Dimensions TeSys® K Contactors
Refer to Catalog 8502CT9901
LR2K
Direct mounting under the contactor Separate mounting with LA7-K0064 terminal block on 35 mm rail
(AM1DP200 or AM1DE200)
Three-phase Wiring Scheme
.31
8
2.56
65 1.77
45
4.57
116
2.28
58
1.97
50
4 x Ø4
1.38
35
2.95
75
3.09 (DP200)
78
3.38 (DE200)
86
1.50
38
3.15
80
1.77
45
1
3
5
2
4
6
95
97
96
98
A
H
Test
Reset/Stop
Internal
Links
1
3
5
13
A1
2
4
6
14
A2
2
4
6
97 95 98 96
– KM1
A2A1 96 95 1314
– KM1
O
95
96
LC1, LP1, LP4K
mini-contactors
On baseplate
On AM1DP200 or DE200 rail ( 35 mm)
On printed circuit board
LA1-K
2.24
57
1.22
31
2.28
58
4 x Ø4
1.38
35
1.97
50
1.77
45
2.24
57
2.28
58
1.77
45
.34
9
A1
A2
2.28
58
1.97
50
2.05
52
1.77
45
10 x Ø.051
10 x Ø1.3
LC2, LC8, LP2, LP5K
reversing mini-contactors
On baseplate
On AM1DP200 or DE200 rail ( 35 mm)
On printed circuit board for reversing contactors or 2 mini-contactors side-by-side
8 x Ø4
3.15
80 3.54
90
1.97
50
LA1-K
1.22
31
2.28
58
2.24
57
2.24
57
2.28
58
3.54
90
.34
9
.34
9
A1
A1
A2
A2
2.28
58
1.97
50
2.05
52
1.77
45
1.77
45
20 x Ø.051
20 x Ø1.3
Table 18.163:
LA2KT
Electronic time delay contact blocks On mini-contactors or reversing mini-contactors
1.34
34 1.50
38
1.06
27
Dual Dimensions: INCHES
Millimeters
2.24
57
1.34
34
2.28
58
LA2-KT
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-50 © 2009 Schneider Electric
All Rights Reserved
Dimensions TeSys® U Motor Starters
Refer to Catalog 8502CT0201
Starter Controllers
Non-reversing Reversing
Note: Minimum electrical clearance:
X1 = 35 mm for Ue = 440 V and 70 mm for Ue = 500 and 690 V,
X2 = 0
aMaximum depth (with MODBUS® communication module)
126
4.96
135a
5.31
154
6.06
X1
X1
45
1.77
X2
X2
126
4.96
135a
5.31
73
2.87
30
1.18
Ø4
.15
163
6.42
Rail Mounting Screw Mounting
224
8.82
45
1.77
120/125
4.72/4.92
233
9.17
29
1.14
Ø4
.15
Rail Mounting Screw Mounting
Reversing block for mounting separately from power base
Rail Mounting Screw Mounting
45
1.77
113
4.45
115
4.53
113
4.45
36
1.41
104
4.09
Ø4
.15
Limiter disconnector LUALB1
aMaximum depth (with MODBUS communication module)
45
1.77
93
3.66
154
6.06
135a
5.31
Door interlock mechanisms
LU9AP00 Door cut-out
508
20.01
11.5
.45
8
.31
55
2.16
230
9.06
Ø7
.27
==
==
54
2.12
54
2.12
Ø43
1.69
4xØ3.5
.13
Dual Dimensions: INCHES
Millimeters
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-51
Dimensions Altistart® U01 and TeSys® U Soft Starters
Refer to Catalog 8502CT9901
TeSys U combination
(non-reversing power base) and ATSU 01N212LT
Mounting on § (35mm) rail with VW3 G4104 connector
TeSys U combination
(non-reversing power base) and
ATSU 01N222LT to ATSU 01N232LT
Mounting on § (35mm) rail with VW3 G4104 connector
150
5.91
284
11.18
45
1.77
9
0.354
314
12.36
45
1.77
170
6.69
9
0.354
TeSys U combination
(non-reversing or reversing power base) and
ATSU 01N2206LT to ATSU 01N212LT
Side-by-side mounting
TeSys U combination
(non-reversing or reversing power base) and ATSU 01N222LT
to ATSU 01N232LT
Side-by-side mounting
VW3 G4104 Power connector
99
3.9
135
5.31
154
6.06
72.2
2.84
9
124
4.88
0.354
99
3.9
135
5.31
72.2
2.84
154
6.06
9
0.354
44.8
1.76
20
0.79
6
0.24
46.6
1.83
28
1.10
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-52 © 2009 Schneider Electric
All Rights Reserved
Dimensions TeSys® Manual Starters and Protectors
Refer to Catalog 2520CT0001
GV2M GV2AD, AM, AN, AU, AS, AX GV2AE Mounting of GV2M
89
66
4416
11
.43
.631.73
2.60
3.5
45 ==
44.5
1.75
1.77
9.39.3
81
18
.37.37.71
3.19
Block GV2AD, AM, AN
Block GV2AU, AS, AX
15
.59
10
.39
c
44.5 44.5
1.75 1.75
On 35 mm rail
C = 78.5 mm (3.09") on AM1DP200 (35 x 7.5 mm)
C = 86 mm (3.39") on AM1DE200, ED200 (35 x 15 mm)
GV2P GV2AD, AM, AN, AU, AS, AX GV2AK00 Mounting of GV2P
89
82
5026
1.02 1.97
3.23
3.50
44.5
61
45
==
1.75
1.77
2.40
.59
15
9.39.3
81
1818
.37.37
3.19
.71
Block GV2AD, AM, AN
Block GV2AU, AS, AX 98
14
.55 3.86
44.5
32
1.26
1.75
44.5
c
44.5
1.75 1.75
13.5
84
.53
3.31
On 35 mm rail
C = 98.5 mm (3.88") on AM1DP200
(35 x 7.5 mm)
C = 106 mm (4.17") on AM1DE200, ED200
(35 x 15 mm)
GV2AF4 + LAD31 GV2P + GV2GH7 GV2P + GV2GH7 + TeSys D contactor
Combination GV2ME + TeSys D range contactor Combination GV2P + TeSys D range
contactor for UL 508 Type E application for UL 508 Type E application
c1
c
d1
d
45
1.77
b
45
1.77
b
c1
c
103
4.07
44
1.73
191
7.50
3.6 (91.4)
3.6 (91.4)
3.8 (96.52)
3.8 (96.52)
GV2ME + LC2D09 to D18 LC2D25 and D32 GV2P + LC2D09 to D18 LC2D25 and D32
b 7.4 (188.6) 7.8 (199) b 6.61 (168.1) 7.9 (199.5)
c1 3.6 (92.7) 3.9 (99) c1 4.6 (116.8) 4.6 (116.8)
c 3.9 (98.2) 4.11 (104.5) c 4.8 (122.3) 4.8 (122.3)
d1 3.9 (98.3) 3.9 (98.3)
d 4.1 (103.8) 1.4 (103.8)
Surface mounting enclosure GV2MC0Flush mounting enclosure GV2MP0 (bracket cut-out)
147
84
3.31
5.79
93
3.66
2xØ5.3x6.3
=
130 ==
=
5.12
a
a4 knock-outs for 16 mm
plastic cable glands or no.
16 conduit.
1...6
84
13
0.51 3.31
/0.04...0.24
b
=b1=
= 93.5 =
106.5
3.68
4.19
71
92.8
6.5
2.8
3.65
0.25
GV2 b b1
IN mm IN mm
MP01, MP02 5.51 140 5.00 127
MP03, MP04 5.24 133 4.61 117
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-53
Dimensions TeSys® Manual Starters and Protectors
Refer to Catalog 2520CT0001
GV2M with GK2AF01 and LC1K GV2M with GV2AF01 and LC1K GV2M with GV2AF01 and LC2K Adapter plate GK2AF01
dimensions in mm
79
3.11
45
152
1.77
6.0
152
90
3.54
6.0
24
5545
135
9.5
.94 .37
1.77 2.17
5.31
45
35
54
105 ±5
35
Ø5.5
5
1.38
1.38
1.77
2.13
4.13 ±.2
.2
.22
Mounting external operator GV2AP0Door cut-out GV2M on panel with GV2AF02 adapter
plate
7.5 mm height compensation plate
GV1F03
min.=150
7
53
65
5.2
==
1.5...5
max.=290
2.56
2.1 5.91
/0.06...0.20
11.42 0.21
.276
54
= =
= =
54
4xØ3.5
0.14
Ø43
1.7
2.13
2.13
80
3.15
50/60
4.2
35
1.38
1.97/2.36
.17
13
0.51
35
1.38
39
1.54
Sets of bus bars, GV2G445, GV2G454, GV2G472
with terminal block GV2G05 Sets of bus bars with terminal block GV1G09 Sets of bus bars GV2G245, GV2G254,
GV2G272
GV3 P
Dimensions Mounting on rail AM1 DE200 or AM1 ED201
X1 = Electrical clearance (ISC max)
40 mm for Ue < 500 V, 50 mm for Ue < 690 V
Blocks GV AN
pp
, GV AD
pp
, GV AM11
Block GV3 AU
pp
and GV3 AS
pp
Mounting on panel, using M4 screws Mounting on pre-slotted mounting plate AM1 PA
Note: Leave a space of 9 mm between 2 manual motor protectors: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible: please consult your regional
sales office.
63
2.5
l
3
.12
18
.71
p
45
1.8
30
1.2
l
IP
GV2G445 0.16 x 1.8" (4 x 45 mm) 7.0" (179 mm) 1.8" (45 mm)
GV2G454 0.16 x 2.1" (4 x 54 mm) 8.1" (206 mm) 2.1" (54 mm)
GV2G472 0.16 x 1.8" (4 x 45 mm) 10.2" (260 mm) 2.8" (72 mm)
I
GV2G245 0.08 x 1.8" (2 x 45 mm) 3.5" (89 mm)
GV2G254 0.08 x 2.1" (2 x 54 mm) 3.9" (98 mm)
GV2G272 0.08 x 2.8"(2 x 72 mm) 4.6" (116 mm)
GV2G354 0.12 x 2.1" (3 x 54 mm) 6.0" (152 mm)
136
X1 X1
132
6864
55 918
(2)
(1)
144
6864
136
3xØ4
137,5
37,5
136
18,7 18,7
137,5
AF1 EA4
183
16
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-54 © 2009 Schneider Electric
All Rights Reserved
Dimensions TeSys® GV7 Manual Starters and Protectors
1 GV7R
Panel Mounting Flush Mounting side by side
1.38
35
1.38
35
1.38
35
=
4.92
125
=
2xØ0.24
2xØ6
= =
1.14
29
1.14
29
1.85
47
3.0
76
3.46
88
3.27
83
= =
4.25
108
4.25
108
= =
4.25
108
= =
Minimum clearance x1 x2
IN (mm) IN (mm)
Painted or insulated metal plate, insulation or insulated bar 0 (0) 1.18 (30)
Bare metal plate U < 440 V 0.20 (5) 1.38 (35)
440 V < U < 600 V 0.39 (10) 1.38 (35)
U > 600 V 0.79 (20) 1.38 (35)
Note: Minimum distance between 2 units mounted side by side = 0.
Motor controllers GV7R Add-on auxiliary contacts, GV7AE11, GV7AB11
Note: A self-adhesive label, supplied with the contact, can be affixed to the front face of the starter
to allow personalized marking according to the function of the contact or contacts.
GV7AU••• GV7AS••• GV7AD111, AD112
x1
x1
x2
x2
2/T1
4/T2
6/T3
1/L1
3/L2
5/L3
21 24
22
11 14
12
91 94
92
8184
82
9897
50 ms
KA1
2324
1314
– KA1
D1
D4
C1
C2
9897
50 ms
– KM1
– KA1
A1A2
A1A2
B1
– KA1
2122
9897
50 ms
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved 18-55
Dimensions TeSys® GV7 Manual Starters and Protectors
GV7AC03
Spreaders
Cabling Smooth Terminals Connectors
a (in/mm)
GV7R0.77/19.5
GV7R220 0.85/21.5
GV7AP03, GV7A04
Direct Rotary Handle Flush Mounting
1.77
45
1.77
45
1.18
30
4.49
114
1.61
41
Z
X
X
2.76
70
2.76
70
0.41
10.5
Z Z
X
0.75
19
a
2.87
73
1.77
45
6.10
155
4.76
121
0
I
DD
60
60
2.17
55
3.58
91
1.42
36
1.10
28
= =
3.82
97
1.14
29
1.85
47
3.0
76
3.5
89
www.schneider-electric.us
18 IEC CONTACTORS AND
STARTERS
18-56 © 2009 Schneider Electric
All Rights Reserved
Dimensions TeSys® GV7 Manual Starters and Protectors
GV7AP03 or GV7AP04, GV7AP05
Direct Rotary Handle Front Fuse Center Enclosure viewed from top
Door cutouts require a minimum distance between the center of the
manual motor protector and the door hinge point (h) of d >/= 3.94 in
(100 mm) + (h x 5)
GV7AP01, GV7AP02
Extended Rotary Handle
Note: I: 7.28" (185 mm) minimum, 23.62" (600 mm) maximum. The shaft of the extended rotary handle GV7AP01 or
GV7AP02 must be cut to length: I - 4.96" (126 mm)
= =
3.94
100
2.32
59
3.94
100
2.72
69
=
2.0
51
4.72
120
=
4.72
120
4.92
125
e0.36
9.25
0.35
9
1.61
41
h
d
2.95
75
=
60
0
I
=
2.95
75
==
l
0.36
9.25
0.35
9
60

Navigation menu