Fluke 370 FC Series True Rms Wireless AC/DC Clamp Meters
2016-08-17
: Pdf 1000442371-Attachment 1000442371-Attachment B3 unilog
Open the PDF directly: View PDF .
Page Count: 5
TECHNICAL DATA
Fluke 370 FC Series
True-rms Wireless AC/DC
Clamp Meters
The new Fluke 370 FC Series (376 FC, 375 FC and 374 FC)
offers advanced troubleshooting performance. The iFlex® flex-
ible current probe allows easy connections to wires in tight spaces.
In addition, all three clamps are now part of the Fluke Connect®
family of wireless test tools. Now you can:
• Log and trend measurements to pinpoint intermittent faults
• Transmit results wirelessly via Fluke Connect® Measurements app
• Create and send reports right from the field
• Capture measurements outside the arc flash zone with Bluetooth
connectivity to your Apple or Android devices
Product highlights
• Connect your meter to your smartphone using Fluke Connect
Measurements app to increase the troubleshooting power of your
clamp
• Read measurements on your phone at a safe distance, wearing
less PPE while your meter takes all the risks
• Record results directly to your phone and the Fluke Cloud™
• Capture intermittent faults while performing other tasks using
the logging capabilities of the Fluke 376 FC and 375 FC
• Create and share reports from the field via email, or converse in
real time with ShareLive™ video calls
• iFlex flexible current probe expands the measurement range to
2500 A ac; provides access to large conductors in tight spaces
(included with 376 FC; compatible with 375 FC and 374 FC)
All trademarks are the property of their respective owners
LOG AND TREND MEASUREMENTS
Transmit results wirelessly via Fluke
Connect® Measurements app
WORK SAFELY
Capture measurements outside the arc
flash zone with Bluetooth connectivity to
your Apple or Android devices
LO-PASS FILTER
Integrated VFD low-pass filter
(Fluke 376 FC and 375 FC) for accurate
motor drive measurements
TRUE-RMS
True-rms voltage and current for accurate
measurements on non-linear signals
WARRANTY
Three-year
2 Fluke Corporation Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters
• TPAK magnetic hanging strap (included with 376 FC; compatible
with 375 FC and 374 FC) allows you to conveniently hang the
meter while using the probes
• Integrated VFD low pass filter (Fluke 376 FC and 375 FC) for
accurate motor drive measurements
• Proprietary in-rush measurement technology to filter out
noise and capture motor starting current exactly as the circuit
protection sees it
• CAT IV 600 V, CAT III 1000 V safety rating
• Three-year warranty
• Soft carrying case
Measurement Capability
• 1000 A ac and dc current measurement (376 FC); 600 A
ac and dc (375 FC and 364 FC)
• 2500 A ac current measurement with iFlex® flexible current
probe
• 1000 V ac and dc voltage measurement
• True-rms voltage and current for accurate measurements
on non-linear signals
• Frequency measurement to 500 Hz with body jaw and iFlex
(376 FC and 375 FC)
• Resistance measurement to 60 kΩ (376 FC and 375 FC)
or 6000 Ω (374 FC), with continuity detection
• Min, max, average and in-rush recording to capture variations
automatically
• 500 mV dc measurement range to interface with other
accessories (376 FC and 375 FC)
• 1000 μF capacitance measurement
3 Fluke Corporation Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters
Comparison chart
Fluke 376 FC Fluke 375 FC Fluke 374 FC
CAT rating CAT III 1000 V, CAT IV 600 V CAT III 1000 V, CAT IV 600 V CAT III 1000 V, CAT IV 600 V
A ac range 999.9 A with clamp jaws
2500 A with iFlex® flexible
current clamp
600 A with clamp jaws
2500 A with optional iFlex®
flexible current clamp
600 A with clamp jaws
2500 A with optional iFlex®
flexible current clamp
A dc range 999.9 A 600 A 600A
Best resolution 0.1 A 0.1 A 0.1 A
V ac range 1000 V 1000 V 1000 V
V dc range 1000 V 1000 V 1000 V
mV dc range 500 mV 500 mV
Ohms range 60.00 kΩ 60.00 kΩ 6,000 Ω
Frequency 5-500.0 Hz 5-500.0 Hz
Capacitance 1 μF-1,000 μF 1 μF-1,000 μF 1 μ-1,000 μF
Auto shutoff •••
True RMS •••
Display hold •••
Inrush measurements •••
Backlight •••
DC zero •••
Min/max •••
VFD low pass filter • •
Logging • •
iFlex® flexible current clamp Included Optional Optional
Fluke Connect® compatible •••
Specifications
General specifications
Maximum voltage between any terminal and earth ground 1000 V
Battery type 2 AA alkaline batteries, NEDA 15A, IEC LR6
Temperature Operating: -10 °C to +50 °C (14 °F to + 122 °F)
Storage: -40 °C to +60 °C (-40 °F to + 140 °F)
Operating humidity Non condensing (< 10 °C (50 °F)), ≤90 % RH (at 10 °C to 30 °C (50 °F to 86 °F)),
≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C
(104 °F to 122 °F))
Altitude Operating: 3,000 m (9,842 ft)
Storage: 12,000 m (39,370 ft)
Dimensions 24.9 cm (9.8 in) x 8.5 cm (3.3 in) x 4.5 cm (1.7 in)
Weight 395 g (13.9 oz)
Jaw opening 34 mm (1.3 in)
Flexible current probe diameter 7.5 mm (.29 in)
Flexible current probe cable length
(head to electronics connector)
1.8 m (70.8 in)
Safety IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
IP rating IEC 60529: IP30, non-operating
Radio frequency certification FCC ID:T68-FBLE IC:6627A-FBLE
4 Fluke Corporation Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters
General specifications continued
Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment,
IEC 61326-2-2 CISPR 11: Group 1, Class A
Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication
Equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device
per clause 15.103.
Temperature coefficients Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C
Function Range Resolution Accuracy Crest factor Trigger level
AC current via
jaw
374 FC and 375 FC:
600.0 A
376 FC: 999.9 A
0.1 A 2 % ±5 digits
(10 Hz to 100 Hz)
3 at 500 A (375 FC and
376 FC only)
2.5 at 600 A
1.42 at 1000 A (376 FC
only)
Add 2 % for C.F. >2
AC current via
flexible current
probe
2500 A 374 FC and 375 FC:
0.1 A (≤ 600.0 A),
1 A (≤ 2500 A)
376 FC: 0.1 A (≤ 999.9 A),
1 A (≤ 2500 A)
3 % ±5 digits
(5 Hz to 500 Hz)
3.0 at 1100 A (375 FC
and 376 FC only)
2.5 at 1400 A
1.42 at 2500 A
Add 2 % for C.F. >2
DC current 374 FC and 375 FC:
600.0 A
376 FC: 999.9 A
0.1 A 2 % ±5 digits
AC voltage 1000 V 0.1 V (≤600.0 V)
1 V (≤1000 V)
1.5 % ±5 digits
(20 Hz to 500 Hz)
DC voltage 1000 V 0.1 V (≤600.0 V)
1 V (≤1000 V)
1 % ±5 digits
mV dc 500.0 mV 0.1 mV 1 % ±5 digits
Frequency via
jaw
375 FC and 376 FC:
5.0 Hz to 500.0 Hz
0.1 Hz 0.5 % ±5 digits 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Frequency via
flexible current
probe
375 FC and 376 FC:
5.0 Hz to 500.0 Hz
0.1 Hz 0.5 % ±5 digits 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Resistance 374 FC: 6,000 Ω
375 FC and 376 FC:
60 kΩ
374 FC: 0.1 Ω (≤600 Ω),
1 Ω (≤6000 Ω)
375 FC and 376 FC: 0.1 Ω
(≤600 Ω), 1 Ω (≤6000 Ω),
10 Ω (≤60 kΩ)
1 % ±5 digits
Capacitance 1000 μF 0.1 μF (≤100 μF),
1 μ F (≤1000 μF)
1 % ±4 digits
5 Fluke Corporation Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters
Ordering information
374 FC 600A AC/DC True-rms Wireless Clamp Meter
375 FC 600A AC/DC True-rms Wireless Clamp Meter
376 FC 1000A AC/DC True-rms Wireless Clamp Meter with iFlex®
Included
18-inch iFlex® Flexible Current Probe (376 FC only)
TPAK Magnetic Hanging Strap (376 FC only)
Soft Carrying Case
TL75 Test Leads
Two AA Alkaline Batteries
Coated Instruction Card
Safety Information Sheet
Optional accessories
TPAK Magnetic Hanging Strap (included with 376 FC)
18-inch iFlex® Flexible Current Probe (included with 376 FC)
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2015 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 8/2015 6005995a-en
Modification of this document is not permitted
without written permission from Fluke Corporation.
Fluke. Keeping your world
up and running.®
• Maximize uptime and make confident maintenance decisions with
data you can trust and trace.
• Save measurements to the Fluke Cloud™ and associate with an asset
so your team can consult both historical and current measurements
from one location.
• Collaborate with ease by sharing your data with others with
ShareLive™ video calls and emails.
• Wireless one-step measurement transfer with AutoRecord™
measurements removes the need for clipboards and paperwork.
• Consult summary views of all assets over time for easy identification
of correlated or periodic failures for easier prioritization of
maintenance work.
• Generate reports with multiple measurement types to provide status
or work recommendations.
Find out more at flukeconnect.com
Download the app at:
Set up and sustain preventive maintenance practices
with ease to help you oversee your complex world
with the Fluke Connect® system of software and
wireless test tools.
Smartphone is not included with purchase.