1000465157 Catalog

2016-09-04

: Pdf 1000465157-Catalog 1000465157-Catalog B4 unilog

Open the PDF directly: View PDF PDF.
Page Count: 33

www.eaton.com
www.arrowhart.com
Q
SECTION
SECTION
Technical
Reference
www.eaton.com
www.eaton.com/arrowhart Q-1
EATON 2016 Arrow Hart Buyers Guide
Q
NEMA configurations Q-2
15A & 20A straight blade Q-2
30A, 50A, & 60A straight blade Q-3
15A, 20A & 30A locking Q-4, Q-6
10A-30A Non-NEMA locking Q-7
50A Non-NEMA locking Q-7
Pin & sleeve & mechanical interlock configurations Q-8
20A & 30A watertight pin & sleeve Q-8
60A & 100A watertight pin & sleeve Q-9
16A & 32A watertight pin & sleeve Q-10
63A & 125A watertight pin & sleeve Q-11
Horsepower ratings Q-12
For NEMA configurations (plugs & receptacles only) Q-12
Common industry information Q-13
Organization abbreviations glossary Q-14
Organization acronyms Q-15
Common UL & CSA standards for wiring devices Q-15
Select NEC® requirements for wiring devices Q-16
Wire & cable information Q-17
Wire & cable type abbreviations Q-17
Diameter ranges of jacketed cord, per UL62 Q-17
Wiring diagrams Q-18
By NEMA: 2-pole, 2-wire non-grounding Q-18
By NEMA: 2-pole, 3-wire grounding Q-18
By NEMA: 3-pole, 3-wire non-grounding Q-18
By NEMA: 3-pole, 4-wire grounding Q-18, Q-19
By NEMA: 4-pole, 4-wire non-grounding Q-19
By NEMA: 4-pole, 5-wire grounding Q-19
Receptacles & GFCI Q-20
Combination devices Q-20
Switches Q-21
Manual contactors & disconnect switches Q-21
Manual contactors & disconnect switches,
by motor variations
Q-22
Dimensional data Q-23
Switches dimensional data Q-23
Enclosures dimensional data Q-24
Snap-in receptacle panel cutouts Q-25
Attachon lampholder cutouts Q-25
Switch applications Q-26
Test requirements Q-26
Maximum loads Q-27
Switch applications or materials Q-28
Chemical resistant properties of common materials Q-28
NEMA & IP enclosures Q-29
NEMA enclosure ratings Q-29
IP enclosure ratings Q-29
Enclosure type cross reference: NEMA/UL/CSA Q-30, Q-31
NAFTA/ROHS compliant Q-32
NAFTA & ROHS compliant criteria Q-32
Table of contents
Q-2
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
Poles, wires
Rating
NEMA prefix
15A Straight blade 20A Straight blade
Receptacle, connector
& flanged outlet
Plug &
flanged inlet
Receptacle, connector
& flanged outlet
Plug &
flanged inlet
2-pole,
2-wire
125V/AC 1
4882 4862
2-pole, 3-wire grounding
125V/AC 5
AH5262C MC
AH5252
6262 D
AHIG5262 IM
AH5269 U
5261 M
1547 Y
VGF15 GM
TRBR15 R
TRVGF15 RGM
5262 M
AH8200 M
8200 HM
8210 M
IG8200 IM
TR8200 RM
VGFH15 GM
TRVGFH15 RGM
5269N NC
5279C
AH5969 O
WRVGF15
60W47 Y
60W47DPLX W
15W47 W
4887
BR15
CR15
IG5262 O
5269NHG N
AH8219HG U
AH8119W O
5266N NC
5278C
AH5266 U
AH5965 O
1447 Y
14W47 W
4867
5266NHG N
AH8215HG U
AH8115W O
AH5362 MC
AH5352 M
6362 DM
AHIG5362 IM
1533 Y
15W33 W
5361 M
VGF20 GM
TRBR20 R
TRVGF20 RGM
5362 M
AH8300 M
8300 M
8310 M
IG8300 IM
TR8300 RM
VGFH20 GM
TRVGFH20 RGM
5369N NC
5779C
AH5369 U
WRVGF20
60W33 W
60W33DPLX W
AH5369Y O
4228
BR20
CR20
IG5362 O
5369NHG N
AH8319HG U
5366N NC
5778C
AH5366 U
AH5364Y O
1433 Y
14W33 W
4409
5366NHG N
AH8315HG U
250V/AC 6
AH5662 M
5661
AHIG5662 I
6662 D
1549 Y
15W49 W
826
816
5662C
AH8600 M
5669N N
5679C
AH5669 U
60W49 W
60W49DPLX W
AH5669Y O
4227
8610
5666N N
5678C
AH5666Y O
AH5666 U
1449 Y
14W49 W
4866
AH8225HG U
AH5462 M
5461
AHIG5462 I
6462 D
1548 Y
15W48 W
815
5462C
AH8400 M
IG8400 I
5469N N
5879C
AH5469 L
60W48 W
60W48DPLX W
AH5469Y O
4229
8410
5466N N
AH5464Y O
5878C
AH5466 U
1448 Y
14W48 W
4509
AH8325HGA AU
277V/AC 7
5302 7624N L
3-pole,
3-wire
125/250V/AC 10
805 9151N L
2836
3-pole, 4-wire
grounding
125/250V/AC 14
5759
3Ø 250V/AC 15
4-pole,
4-wire
3ØY
120/208V/AC 18
7251N L
Device body: Device type: Device options available:
Duplex receptacle Flanged inlet AAngled NAuto grip C Corrosion resistant
Single receptacle Flanged outlet DDecorator OQuick grip MArrowLink modular
Plug Hull inlet GGFCI RTamper resistant WWatertight
Connector Mechanical interlock HCompact SSurface YSevere duty insulated
Open shape has holes (receptacles, connectors, outlets)
Closed shape has blades (plugs, inlets) I
L
Isolated ground
Safety grip
UUltra grip
Due to spatial constraints not all products are shown on this page. For additional product options in these configurations consult sections A, B, I, J & K.
Straight blade legend: How to use the chart
Core catalog number color
indicates a device’s grade:
BLACK = Industrial specification grade A suffix combining a RED shape and alpha letter indicate
a device’s body, type and available options.
BLUE = Commercial specification grade
ORANGE = Construction specification grade
GREEN = Hospital specification grade
NEMA configurations for select devices
www.eaton.com
www.eaton.com/arrowhart Q-3
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
Poles, wires
Rating
NEMA prefix
30A Straight blade 50A Straight blade 60A Straight blade
Receptacle,
connector & flanged outlet
Plug &
flanged inlet
Receptacle,
connector & flanged
outlet
Plug &
flanged inlet
Receptacle,
connector & flanged
outlet
Plug &
flanged inlet
2-pole,
2-wire
125V/AC 1
2-pole, 3-wire grounding
125V/AC 5
6716N N
1233
5716N
5717AN AN
5717N N
5717NFI N
S41 A
6711N N
1253
5712AN AN
5712N N
5712NFI N
S41 A
250V/AC 6
6700N N
5700N
1232 S
1234
5701AN AN
5701N N
5701NFI N
S42 A
6709N N
5709N
1252 S
1254
5710AN AN
5710N N
5710NFI N
S42 A
277V/AC 7
6795N N
5795N
5703AN AN
5703N N
5703NFI N
6796N N5705AN AN
5705N N
5705NFI N
3-pole, 3-wire
125/250V/AC 10
9341N N
38B
125 S
9352AN AN
9337N N
9337NFI N
S80 A
4526N N
7985N
32B
112 S
122B
4524N N
4524NFI N
7952AN AN
S80 A
3-pole, 4-wire
grounding
125/250V/AC 14
5744N
1225 S
1257
5732AN AN
5746N N
S21 A
5754N
1212 S
1258
5752AN AN
5745N N
S21 A
9460N 9462AN AN
9462N N
S20 AN
3Ø 250V/AC 15
8430N 8432AN AN
8432N N
8450N 8452AN AN
8452N N
8460N
AH8462AN
AN
AH8462N N
4-pole, 4-wire
3ØY
120/208V/AC 18
8332AN AN
8332N N
8352AN AN
8352N N
5515N 4516AN N
5517N N
S19 A
Device body: Device type: Device options available:
Duplex receptacle Flanged inlet AAngled NAuto grip C Corrosion resistant
Single receptacle Flanged outlet DDecorator OQuick grip MArrowLink modular
Plug Hull inlet GGFCI RTamper resistant WWatertight
Connector Mechanical interlock HCompact SSurface YSevere duty insulated
Open shape has holes (receptacles, connectors, outlets)
Closed shape has blades (plugs, inlets) I
L
Isolated ground
Safety grip
UUltra grip
Due to spatial constraints not all products are shown on this page. For additional product options in these configurations consult sections A, B, I, J & K.
Straight blade legend: How to use the chart
Core catalog number color
indicates a device’s grade:
BLACK = Industrial specification grade A suffix combining a RED shape and alpha letter indicate
a device’s body, type and available options.
BLUE = Commercial specification grade
ORANGE = Construction specification grade
GREEN = Hospital specification grade
NEMA configurations for select devices
Q-4
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
Poles,
wires
Rating
NEMA
prefix
15A Locking 20A Locking
Receptacle, connector
& flanged outlet
Plug &
flanged inlet
Receptacle, connector
& flanged outlet
Plug &
flanged inlet
2-pole, 2-wire
125V/AC ML1
7464N
7427N
7468
7465N
7428N
7479N
7429N
7466
7467
125V/AC L1
CWL115FO
CWL115R
7506
7540
CWL115FI
7546
7548
250V/AC L2
65W47 W 65W47DPLX WCWL220C L
CWL220FO
CWL220R
CWL220P L
CWL220P-6 ZL
2-pole, 3-wire grounding
125V/AC ML2
7593
7596
7596N
7594
7595
7595N
125V/AC L5
CWL515C L
CWL515FO
IG4700 I
65W47 W
25W47 W
CR4700 C
4731N N
CR5792 C
CWL515CAN AL
CWL515R
IGL515R I
65W47DPLX W
4731NCR CN
2547 Y
4700
5792
CWL515FI
CWL515P L
CWL515PAN AL
24W47 W
2447 Y
4721N N
4721NCR CN
AHL520C U
AHL520FO
IGL520R I
L520CW W
L520CY Y
L520RW W
CRL520C CL
CRL520R C
AHL520CBK U
AHL520R
AHL520FI
AHL520P U
CWL520PBK L
L520PW W
L520PY Y
CRL520P CL
250V/AC L6
CWL615C L
CWL615R
IGL615R I
2549 Y
6566N N
CWL615FO
65W49DPLX W
25W49 W
65W49 W
6580
CWL615FI
CWL615P L
24W49 W
2449 Y
6565N N
AHL620C U
AHL620R
L620CW W
L620RW W
CRL620R C
CRL620C CL
AHL620FO
IGL620R I
L620CY Y
AHL620FI
AHL620P U
L620PW W
L620PY Y
CRL620P C
277V/AC L7
CWL715C
CWL715R
25W34 W
65W34 W
4772N N
CWL715FO
65W34DPLX W
4750
2534 Y
CWL715FI
CWL715P L
24W34 W
2434 Y
4771N N
AHL720C U
AHL720FO
AHL720R
IGL720R I
L720CW W
L720CY Y
L720RW W
AHL720FI
AHL720P U
L720PW W
L720PY Y
480V/AC L8
AHL820C U
AHL820R
L820CW W
L820CY Y
AHL820FO
IGL820R I
L820RW W
AHL820FI
AHL820P U
L820PW W
L820PY Y
600V/AC L9
CWL920C
CWL920FO
CWL920R
CWL920FI
CWL920P
3-pole, 3-wire
125/250V/AC ML3
7484
7487
7487N
7485
7486
7486N
125/250V/AC L10
AHL1020C U
AHL1020R
L1020CY Y
L1020RW W
L1020CW W
AHL1020FO
AHL1020FI
AHL1020P U
L1020PW W
L1020PY Y
3Ø 250V/AC L11
AHL1120C U
AHL1120R
L1120CY Y
L1120RW W
AHL1120FO
L1120CW W
AHL1120FI
AHL1120P U
L1120PW W
L1120PY Y
3Ø 480V/AC L12
CWL1220C
CWL1220FO
CWL1220R
CWL1220FI
CWL1220P
3Ø 600V/AC L13
Device body: Device type:
Duplex receptacle Single receptacle AAngled LSafety grip UUltra grip ZWith lid or cover
Plug Flanged inlet CCorrosion resistant NAuto grip WWatertight
Connector Flanged outlet IIsolated ground PPro grip YSevere duty insulated
Open shape has holes (receptacles, connectors, outlets)
Closed shape has blades (plugs, inlets)
Locking device legend: How to use the chart
Core catalog number color
indicates a device’s grade:
BLACK = Industrial specification grade A suffix combining a RED shape and alpha letter indicate
a device’s body, type and available options.
NEMA configurations for select devices
www.eaton.com
www.eaton.com/arrowhart Q-5
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
Poles,
wires
Rating
NEMA
prefix
30A Locking
Receptacle, connector,
& flanged outlet
Plug &
flanged inlet
2-pole, 2-wire
125V/AC ML1
125V/AC L1
250V/AC L2
2-pole, 3-wire grounding
125V/AC ML2
125V/AC L5
AHL530FO
AHL530R
L530CW W
L530RW W
CRL530C C
L
CRL530R C
AHL530C
U
IGL530R I
L530CY Y
AHL530FI
AHL530P
U
IGL530P I
L
L530PW W
L530PY Y
CRL530P C
L
250V/AC L6
AHL630C
U
AHL630R C
L630CW W
L630RW W
CRL630C C
L
CRL630R C
AHL630FO
IGL630R I
L630CY Y
AHL630FI
AHL630P
U
L630PW W
L630PY Y
CRL630P C
L
277V/AC L7
AHL730C
U
AHL730R
L730CW W
L730CY Y
L730RW W
AHL730FO
IGL730R I
AHL730FI
AHL730P
U
L730PW W
L730PY Y
480V/AC L8
AHL830C
U
AHL830R
L830CW W
L830CY Y
L830RW W
AHL830FO
IGL830R I
AHL830FI
AHL830P
U
L830PW W
L830PY Y
600V/AC L9
CWL930C
CWL930FO
CWL930R
CWL930FI
CWL930P
3-pole, 3-wire
125/250V/AC ML3
125/250V/AC L10
AHL1030C
U
AHL1030R
L1030CW W
L1030CY Y
L1030RW W
AHL1030FO
AHL1030FI
AHL1030P
U
L1030PW W
L1030PY Y
3Ø 250V/AC L11
AHL1130C
U
AHL1130R
L1130CW W
L1130CY Y
L1130RW W
AHL1130FO
AHL1130FI
AHL1130P
U
L1130PW W
L1130PY Y
3Ø 480V/AC L12
CWL1230C
CWL1230FO
CWL1230R
CWL1230FI
CWL1230P
3Ø 600V/AC L13
CWL1330C
CWL1330FO
CWL1330R
CWL1330FI
CWL1330P
For NEMA configurations L14 through L23,
see page Q-6
Device body: Device type:
Duplex receptacle Single receptacle AAngled LSafety grip UUltra grip ZWith lid or cover
Plug Flanged inlet CCorrosion resistant NAuto grip WWatertight
Connector Flanged outlet IIsolated ground PPro grip YSevere duty insulated
Open shape has holes (receptacles, connectors, outlets)
Closed shape has blades (plugs, inlets)
Locking device legend: How to use the chart
Core catalog number color
indicates a device’s grade:
BLACK = Industrial specification grade A suffix combining a RED shape and alpha letter indicate
a device’s body, type and available options.
NEMA configurations for select devices
Q-6
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
Poles, wires
Rating
NEMA prefix
20A Locking 30A Locking
Receptacle, connector
& flanged outlet
Plug &
flanged inlet
Receptacle, connector,
& flanged outlet
Plug &
flanged inlet
3-pole, 4-wire grounding
125/250V/AC L14
AHL1420C U
AHL1420FO
IGL1420R I
L1420CW W
CRL1420C CL
CRL1420R C
6406BK
AHL1420CBK U
AHL1420R
L1420CY Y
L1420RW W
AHL1420FI
AHL1420P U
AHL1420PBK U
L1420PW W
L1420PY Y
CRL1420P CL
6405BK
AHL1430C U
AHL1430R
L1430CW W
L1430CY Y
L1430RW W
CRL1430C CL
CRL1430R C
AHL1430FO
IGL1430R I
AHL1430FI
AHL1430P U
L1430PW W
L1430PY Y
CRL1430P CL
6512BK
3Ø 250V/AC L15
AHL1520C U
AHL1520R
L1520CW W
L1520RW W
CRL1520C CL
CRL1520R C
CWL1520FO
IGL1520R I
L1520CY Y
AHL1520FI
AHL1520P U
L1520PW W
L1520PY Y
CRL1520P CL
AHL1530C U
AHL1530R
L1530CW W
L1530CY Y
L1530RW W
CRL1530C CL
AHL1530FO
IGL1530R I
AHL1530FI
AHL1530P U
L1530PW W
L1530PY Y
CRL1530P CL
3Ø 480V/AC L16
AHL1620C U
AHL1620FO
IGL1620R I
L1620CW W
L1620CY Y
L1620RW W
CRL1620C CL
AHL1620CBK U
AHL1620R
AHL1620P U
AHL1620PBK U
L1620PW W
L1620PY Y
CRL1620P CL
AHL1620FI
AHL1630C U
AHL1630FO
AHL1630R
L1630CW W
L1630CY Y
L1630RW W
AHL1630FI
AHL1630P U
L1630PW W
L1630PY Y
CRL1630P CL
3Ø 600V/AC L17
AHL1730C U
AHL1730R
L1730CW W
L1730CY Y
L1730RW W
AHL1730FO
AHL1730FI
AHL1730P U
L1730PW W
L1730CY Y
4-pole, 4-wire
3ØY
120/208V/AC L18
AHL1820C U
AHL1820R
L1820CW W
L1820CY Y
L1820RW W
AHL1820FO AHL1820FI
AHL1820P U
L1820PW W
L1820PY Y
AHL1830C U
AHL1830R
L1830CW W
L1830CY Y
L1830RW W
AHL1830FO
AHL1830FI
AHL1830P U
L1830PW W
L1830PY Y
3ØY
277/480V/AC L19
AHL1920C U
AHL1920R
L1920CW W
L1920CY W
L1920RW W
AHL1920FO
AHL1920FI
AHL1920P U
L1920PW W
L1920PY Y
AHL1930C U
AHL1930R
L1930CW W
L1930CY Y
L1930RW W
AHL1930FO
AHL1930FI
AHL1930P U
L1930PW W
L1930PY Y
3ØY
347/600V/AC L20
AHL2020C U
AHL2020R
L2020CW W
L2020CY Y
L2020RW W
AHL2020FO AHL2020FI
AHL2020P U
L2020PW W
L2020PY Y
AHL2030C U
AHL2030R
L2030CW W
L2030CY Y
L2030RW W
AHL2030FO AHL2030FI
AHL2030P U
L2030PW W
L2030PY Y
4-pole, 5-wire
grounding
3ØY
120/208V/AC L21
AHL2120C U
AHL2120FO
IGL2120R I
L2120CW W
L2120CY Y
L2120RW W
AHL2120CBK U
AHL2120R
L2120CF L
AHL2120FI
AHL2120P U
AHL2120PBK U
L2120PW W
L2120PY Y
L2120PF L
AHL2130C U
AHL2130R
L2130CW W
L2130CY W
L2130RW W
L2130CF L
AHL2130FO
IGL2130R I
AHL2130FI
AHL2130P U
L2130PW W
L2130PY Y
L2130PF L
3ØY
277/480V/AC L22
AHL2220C U
AHL2220R
IGL220R I
L2220CW W
L2220CY Y
L2220RW W
AHL2220FO AHL2220FI
AHL2220P U
L2220PW W
L2220PY Y
AHL2230C U
AHL2230R
IGL2230R I
L2230CW W
L2230CY Y
L2230RW W
AHL2230FO
L22230CF L
AHL2230FI
AHL2230P U
L2230PW W
L2230PY Y
L2230PF L
3ØY
347/600V/AC L23
AHL2320C U
AHL2320R
IGL2320R I
L2320CW W
L2320CY Y
L2320RW W
AHL2320FO AHL2320FI
AHL2320P U
L2320PW W
L2320PY Y
AHL2330C U
AHL2330R
IGL2330R I
L2330CW W
L2330CY Y
L2330RW W
AHL2330FO AHL2330FI
AHL2330P U
L2330PW W
L2330PY Y
Device body: Device type:
Duplex receptacle Flanged inlet AAngled LSafety grip WWatertight
Single receptacle Flanged outlet CCorrosion resistant NAuto grip YSevere duty insulated
Plug Hull inlet IIsolated ground UUltra grip
Connector Mechanical interlock
Open shape has holes (receptacles, connectors, outlets)
Closed shape has blades (plugs, inlets)
Locking device legend: How to use the chart
Core catalog number color
indicates a device’s grade:
BLACK = Industrial specification grade A suffix combining a RED shape and alpha letter indicate
a device’s body, type and available options.
NEMA configurations for select devices
www.eaton.com
www.eaton.com/arrowhart Q-7
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
Poles, wires
Rating
50A Non-NEMA locking
Receptacle & connector Plug, flanged
inlets & hull inlet
2-pole, 3-wire grounding
125V/AC
Marine
corrosion
resistant
63CR60EX P
63CR60 T
63CR70
63CR61EX P
63CR61 T
125V/AC
California
standard
CS6360EX P
CS6360 T
CS6370
CS6361EX P
CS6361 T
CS6377
CS6378 Z
250V/AC
California
standard
CS8264EX P
CS8264 T
CS8269
CS8265EX P
CS8265 T
CS8275
CS8277 Z
250V/DC
600V/AC
3762EX P
3762 T
3771
3763EX P
3763 T
3777
3767 Z
480V/AC
California
standard
CS8464EX P
CS8464 T
CS8469
CS8465EX P
CS8465 T
CS8475
CS8477 Z
3-pole, 4-wire grounding
125/250V/AC
Marine
corrosion
resistant
63CR64EX P
63CR64 T
63CR69
63CR65EX P
63CR65 T
125/250V/AC
California
standard
CS6364EX P
CS6364 T
CS6369
CS6365EX P
CS6365 T
CS6375
CS6376 Z
3Ø 250V/AC
California
standard
CS8364EX P
CS8364 T
CS8369
CS8365EX P
CS8365 T
CS8375
CS8377 Z
250V/DC
600V/AC
3764EX P
3764 T
3769
3765EX P
3765 T
3775
3768 Z
250V/DC
600V/AC
7764EX P
7764 T
7379
7765EX P
7765 T
7958
7968 Z
3Ø 480V/AC
California
standard
CS8164EX P
CS8164 T
CS8169
CS8165EX P
CS8165 T
CS8175
CS8177 Z
Plug
Non-NEMA
50A 125V
Marine CR
G
Receptacle
Non-NEMA
50A 125V
Marine CR
G
Plug
Non-NEMA
50A 125V
CA Standard
W
G
Receptacle
Non-NEMA
50A 125 V
CA Standard
W
G
Plug
Non-NEMA
50A 250V
CA Standard
X
G
Y
Recptacle
Non-NEMA
50A 250V
CA Standard
X
GY
Plug
Non-NEMA
50A 2P, 3W
250V DC/600V AC
G
XY
Receptacle
G
X
Y
Plug
Non-NEMA
50A 250V
CA Standard
X
G
Y
Receptacle
Non-NEMA
50A 250V
CA Standard
X
G
Y
Plug
Non-NEMA
50A 125/250V
Marine CR
GWX
Y
Receptacle
Non-NEMA
50A 125/250V
Marine CR
G
W
X
Y
Plug
Non-NEMA
50A 125/250V
CA Standard
G
WX
Y
Receptacle
Non-NEMA
50A 125/250V
CA Standard
G
W
X
Y
Plug
Non-NEMA
50A 3Ø 250V
CA Standard
GZX
Y
Receptacle
Non-NEMA
50A 3Ø 250V
CA Standard
G
Z
X
Y
Plug
Non-NEMA
50A 3P, 4W
250V DC/600V AC
3765, 3768, 3775
X
Y
Z
G
Receptacle
Non-NEMA
50A 3P, 4W
250V DC/600V AC
3764, 3769
X
Y
ZG
Plug
Non-NEMA
50A 3P, 4W
250V DC/600V AC
7765, 7958, 7968
XY
Z
G
Receptacle
Non-NEMA
50A 3P, 4W
250V DC/600V AC
7764, 7379
X
Y
Z
G
Plug
Non-NEMA
50A 3Ø 480V
CA Standard
G
XY
Z
Receptacle
Non-NEMA
50A 3Ø 480V
CA Standard
G
X
Y
Z
Poles, wires
Rating
10A - 30A
Non-NEMA locking
Receptacle, connector,
& flanged outlet
Plug &
flanged inlet
3-pole, 3-wire
10/15A
125/250V/AC
4755 L
7565N N
7580
7582
4767 L
4767AN AL
7567N N
20A
125/250V/AC
7310B
7314C L
7314CW W
7314CY Y
7314RW W
7328N
7327N
9965C L
9965PW W
9965PY Y
30A
125/250V/AC
3330-2
3333CW W
3333CY Y
3333RW W
AH3333N U
3336N
AH3331N U
3331PW W
3331PY Y
3337N
4-pole, 4-wire
20A 3Ø
120/208V/AC
7409N
7410B
7413C L
7413CW W
7413CY Y
7413RW W
7408N
7411C L
7411PW W
7411PY Y
30A 3Ø
120/208V/AC
3430
3433CW W
3433CY Y
AH3433N U
3433RW W
3436N
AH3431N U
3431PW W
3431PY Y
3434N
4-P, 5-W grounding
20/10A
250/600V/AC
AH3523BK U
3525BK
AH3521BK U
3524BK
Plug
Non-NEMA
15A 125V
10A 250V
CU
G
Receptacle
Non-NEMA
15A 125V
10A 250V
CU
G
Plug
Non-NEMA
20A
125/250V
Y
W
X
Receptacle
Non-NEMA
20A
125/250V
Y
W
X
Plug
Non-NEMA
30A
125/250V
Y
W
X
Receptacle
Non-NEMA
30A
125/250V
Y
W
X
Plug
Non-NEMA
20A 3Ø
120/208V
YW
X
Z
Receptacle
Non-NEMA
20A 3Ø
120/208V
Y
W
X
Z
Plug
Non-NEMA
30A 3Ø
120/208V
YW
X
Z
Receptacle
Non-NEMA
30A 3Ø
120/208V
Y
W
X
Z
Plug
Non-NEMA
20A 250V
10A 600V
Y
W
Z
X
G
Receptacle
Non-NEMA
20A 250V
10A 600V
Y
W
Z
X
G
Device body: Device type:
Duplex receptacle Flanged inlet AAngled NAuto grip UUltra grip ZWith lid or cover
Single receptacle Flanged outlet CCorrosion resistant PPro grip WWatertight
Plug Hull inlet LSafety grip TArmored body YSevere duty insulated
Connector Mechanical interlock
Open shape has holes (receptacles, connectors, outlets)
Closed shape has blades (plugs, inlets)
Locking device legend: How to use the chart
Core catalog number color
indicates a device’s grade:
BLACK = Industrial specification grade A suffix combining a RED shape and alpha letter indicate
a device’s body, type and available options.
NEMA configurations for select devices
Q-8
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
Poles, wires
Rating 20A watertight pin & sleeve 30A watertight pin & sleeve
Receptacle, connector
& mechanical interlocks Plug & inlet Receptacle, connector
& mechanical interlocks Plug & inlet
2-pole, 3-wire grounding
125V
CD320HMI4W QX
AH320R4W
AH320C4W
AH320P4W
AH320B4W
CD330MI4W Q
AH330R4W
AH330C4W
AH330P4W
AH330B4W
250V
CD320HMI6W QX
AH320R6W
AH320C6W
AH320P6W
AH320B6W
CD330MI6W Q
CD330MIF6W E
AH330R6W
AH330C6W
AH330P6W
AH330B6W
480V/AC
CD320HMI7W QX
AH320R7W
AH320C7W
AH320P7W
AH320B7W
CD330MI7W Q
AH330R7W
AH330C7W
AH330P7W
AH330B7W
3-pole, 4-wire grounding
125/250V/AC
CD420HMI12W QX
CD420MIB12W F
CD420MICB12W B
CD420MIF12W E
AH420R12W
AH420C12W
AH420P12W
AH420B12W
CD430MI12W Q
CD430MIB12W F
CD430MICB12W B
CD430MIF12W E
AH430R12W
AH430C12W
AH430P12W
AH430B12W
3Ø 250V/AC
CD420HMI9W QX
CD420MIB9W F
CD420MICB9W B
CD420MIF9W E
AH420R9W
AH420C9W
AH420P9W
AH420B9W
CD430MI9W Q
CD430MIB9W F
CD430MICB9W B
CD430MIF9W E
AH430R9W
AH430C9W
AH430P9W
AH430B9W
3Ø 480V/AC
CD420HMI7W QX
CD420MIB7W F
CD420MICB7W B
CD420MIF7W E
AH420R7W
AH420C7W
AH420P7W
AH420B7W
CD430MI7W Q
CD430MIB7W F
CD430MICB7W B
CD430MIF7W E
AH430R7W
AH430C7W
AH430P7W
AH430B7W
3Ø 600V/AC
CD420HMI5W QX
AH420R5W
AH420C5W
AH420P5W
AH420B5W
CD430MI5W Q
CD430MIF5W E
AH430R5W
AH430C5W
AH430P5W
AH430B5W
4-pole, 5-wire grounding
3ØY
120/208V/AC
CD520HMI9W QX
AH520R9W
AH520C9W
AH520P9W
AH520B9W
CD530MI9W Q
CD530MIB9W F
CD530MICB9W B
AH530R9W
AH530C9W
AH530P9W
AH530B9W
3ØY
277/480V/AC
AH520R7W
AH520C7W
AH520P7W
AH520B7W
CD530MI7W Q
CD530MIB7W F
CD530MICB7W B
AH530R7W
AH530C7W
AH530P7W
AH530B7W
3ØY
347/600V/AC
AH520R5W
AH520C5W
AH520P5W
AH520B5W
CD530MI5W Q
CD530MIB5W F
CD530MICB5W B
AH530R5W
AH530C5W
AH530P5W
AH530B5W
Receptacle
Pin & Sleeve
20A 2P, 3W
125V AC
Plug
Pin & Sleeve
20A 2P, 3W
125V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
125V AC
Plug
Pin & Sleeve
20A 2P, 3W
125V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
250V AC
Plug
Pin & Sleeve
20A 2P, 3W
250V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
250V AC
Plug
Pin & Sleeve
20A 2P, 3W
250V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
480V AC
Plug
Pin & Sleeve
20A 2P, 3W
480V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
480V AC
Plug
Pin & Sleeve
20A 2P, 3W
480V AC
Receptacle
Pin & Sleeve
3P, 4W
125/250V AC
Plug
Pin & Sleeve
3P, 4W
125/250V AC
Receptacle
Pin & Sleeve
3P, 4W
125/250V AC
Plug
Pin & Sleeve
3P, 4W
125/250V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 250V AC
Plug
Pin & Sleeve
3P, 4W
3Ø 250V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 250V AC
Plug
Pin & Sleeve
3P, 4W
3Ø 250V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 480V AC
Plug
Pin & Sleeve
3P, 4W
3Ø 480V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 480V AC
Plug
Pin & Sleeve
3P, 4W
3Ø 480V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 600V AC
Plug
Pin & Sleeve
3P, 4W
3Ø 600V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 600V AC
Plug
Pin & Sleeve
3P, 4W
3Ø 600V AC
Receptacle
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Receptacle
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Receptacle
Pin & Sleeve
4P, 5W
3ØY 277/480V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 277/480V AC
Receptacle
Pin & Sleeve
4P, 5W
3ØY 277/480V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 277/480V AC
Receptacle
Pin & Sleeve
4P, 5W
3ØY 347/600V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 347/600V AC
Receptacle
Pin & Sleeve
4P, 5W
3ØY 347/600V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 347/600V AC
Device body: Device type:
Single receptacle Flanged inlet BCircuit breaker option FFuse option XHorizontal
Plug Mechanical interlock EFusible QNon-fusible
Connector
Open shape has holes (receptacles, connectors, outlets)
Closed shape has blades (plugs, inlets)
Locking device legend: How to use the chart
Core catalog number color
indicates a device’s grade:
BLACK = Industrial specification grade A suffix combining a RED shape and alpha letter indicate
a device’s body, type and available options.
Pin & sleeve and mechanical interlock configurations
North American Standard Amp Rating
www.eaton.com
www.eaton.com/arrowhart Q-9
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
Poles, wires
Rating
60A watertight pin & sleeve 100A watertight pin & sleeve
Receptacle, connector
& mechanical interlocks Plug & inlet Receptacle, connector
& mechanical interlocks Plug & inlet
2-pole, 3-wire grounding
125V
AH360R4W
AH360C4W
AH360P4W
AH360B4W
CD3100MI4W Q
AH3100R4W
AH3100C4W
AH3100P4W
AH3100B4W
250V
CD360MI6W Q
CD360MIF6W E
AH360R6W
AH360C6W
AH360P6W
AH360B6W
CD3100MI6W Q
AH3100R6W
AH3100C6W
AH3100P6W
AH3100B6W
480V/AC
CD360MI7W Q
AH360R7W
AH360C7W
AH360P7W
AH360B7W
CD3100MI7W Q
AH3100R7W
AH3100C7W
AH3100P7W
AH3100B7W
3-pole, 4-wire grounding
125/250V/AC
CD460MI12W Q
CD460MIB12W F
CD460MICB12W B
CD460MIF12W E
AH460R12W
AH460C12W
AH460P12W
AH460B12W
CD4100MI12W Q
AH4100R12W
AH4100C12W
AH4100R12W-15 A
AH4100P12W
AH4100B12W
3Ø 250V/AC
CD460MI9W Q
CD460MIB9W F
CD460MICB9W B
CD460MIF9W E
AH460R9W
AH460C9W
AH460P9W
AH460B9W
CD4100MI9W Q
AH4100R9W
AH4100C9W
AH4100P9W
AH4100B9W
3Ø 480V/AC
CD460MI7W Q
CD460MIB7W F
CD460MICB7W B
CD460MIF7W E
AH460R7W
AH460C7W
AH460P7W
AH460B7W
CD4100MI7W Q
AH4100R7W
AH4100C7W
AH4100R7W-15 A
AH4100P7W
AH4100B7W
3Ø 600V/AC
CD460MI5W Q
CD460MIB5W F
CD460MICB5W B
CD460MIF5W E
AH460R5W
AH460C5W
AH460P5W
AH460B5W
CD4100MI5W Q
AH4100R5W
AH4100C5W
AH4100P5W
AH4100B5W
4-pole, 5-wire grounding
3ØY
120/208V/AC
CD560MI9W Q
CD560MIB9W F
CD560MICB9W B
CD560MIF9W E
AH560R9W
AH560C9W
AH560R9W-15 A
AH560P9W
AH560B9W
CD5100MI9W Q
AH5100R9W
AH5100C9W
AH5100R9W-15 A
AH5100P9W
AH5100B9W
3ØY
277/480V/AC
CD560MI7W Q
CD560MIB7W F
CD560MICB7W B
CD560MIF7W E
AH560R7W
AH560C7W
AH560P7W
AH560B7W
CD5100MI7W Q
AH5100R7W
AH5100C7W
AH5100R7W-15 A
AH5100P7W
AH5100B7W
3ØY
347/600V/AC
CD560MI5W Q
CD560MIF5W E
AH560R5W
AH560C5W
AH560P5W
AH560B5W
CD5100MI5W Q
AH5100R5W
AH5100C5W
AH5100P5W
AH5100B5W
Receptacle
Pin & Sleeve
20A 2P, 3W
125V AC
Plug
Pin & Sleeve
20A 2P, 3W
125V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
125V AC
Plug
Pin & Sleeve
20A 2P, 3W
125V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
250V AC
Plug
Pin & Sleeve
20A 2P, 3W
250V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
250V AC
Plug
Pin & Sleeve
20A 2P, 3W
250V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
480V AC
Plug
Pin & Sleeve
20A 2P, 3W
480V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
480V AC
Plug
Pin & Sleeve
20A 2P, 3W
480V AC
Receptacle
Pin & Sleeve
3P, 4W
125/250V AC
Plug
Pin & Sleeve
3P, 4W
125/250V AC
Receptacle
Pin & Sleeve
3P, 4W
125/250V AC
Plug
Pin & Sleeve
3P, 4W
125/250V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 250V AC
Plug
Pin & Sleeve
3P, 4W
3Ø 250V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 250V AC
Plug
Pin & Sleeve
3P, 4W
3Ø 250V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 480V AC
Plug
Pin & Sleeve
3P, 4W
3Ø 480V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 480V AC
Plug
Pin & Sleeve
3P, 4W
3Ø 480V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 600V AC
Plug
Pin & Sleeve
3P, 4W
3Ø 600V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 600V AC
Plug
Pin & Sleeve
3P, 4W
3Ø 600V AC
Receptacle
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Receptacle
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Receptacle
Pin & Sleeve
4P, 5W
3ØY 277/480V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 277/480V AC
Receptacle
Pin & Sleeve
4P, 5W
3ØY 277/480V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 277/480V AC
Receptacle
Pin & Sleeve
4P, 5W
3ØY 347/600V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 347/600V AC
Receptacle
Pin & Sleeve
4P, 5W
3ØY 347/600V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 347/600V AC
Device body: Device type:
Single receptacle Flanged inlet AAngled FFuse option XHorizontal
Plug Mechanical interlock BCircuit breaker option QNon-fusible
Connector EFusible
Open shape has holes (receptacles, connectors, outlets)
Closed shape has blades (plugs, inlets)
Locking device legend: How to use the chart
Core catalog number color
indicates a device’s grade:
BLACK = Industrial specification grade A suffix combining a RED shape and alpha letter indicate
a device’s body, type and available options.
Pin & sleeve and mechanical interlock configurations
North American Standard Amp Rating
Q-10
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
Poles, wires
Rating 16A watertight pin & sleeve 32A watertight pin & sleeve
Receptacle & connector Plug & inlet Receptacle & connector Plug & inlet
2-pole, 3-wire grounding
110-130V
AH316R4W
AH316C4W
AH316P4W
AH316B4W
AH332R4W
AH332C4W
AH332P4W
AH332B4W
220-240V
AH316R6W
AH316C6W
AH316P6W
AH316B6W
AH332R6W
AH332C6W
AH332P6W
AH332B6W
3-pole, 4-wire grounding
380/50
440/60
AH332R3W
AH332C3W
AH332P3W
AH332B3W
380-415V
AH416R6W
AH416C6W
AH416P6W
AH416B6W
AH432R6W
AH432C6W
AH432P6W
AH432B6W
4-pole, 5-wire
grounding
220/380
240/415
AH516R6W
AH516C6W
AH516P6W
AH516B6W
AH532R6W
AH532C6W
AH532P6W
AH532B6W
Receptacle
Pin & Sleeve
20A 2P, 3W
125V AC
Plug
Pin & Sleeve
20A 2P, 3W
125V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
125V AC
Plug
Pin & Sleeve
20A 2P, 3W
125V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
250V AC
Plug
Pin & Sleeve
20A 2P, 3W
250V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
250V AC
Plug
Pin & Sleeve
20A 2P, 3W
250V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Pin & sleeve configurations
Device body:
Single receptacle Plug Connector Flanged inlet
Open shape has holes (receptacles, connectors, outlets)
Closed shape has blades (plugs, inlets)
Locking device legend: How to use the chart
Core catalog number color
indicates a device’s grade:
BLACK = Industrial specification grade
International Standard Amp Rating
Receptacle
Pin & Sleeve
3P, 4W
3Ø 250V AC
Receptacle
Pin & Sleeve
3P, 4W
3Ø 250V AC
www.eaton.com
www.eaton.com/arrowhart Q-11
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
Poles, wires
Rating
63A watertight pin & sleeve 125A watertight pin & sleeve
Receptacle & connector Plug & inlet Receptacle & connector Plug & inlet
2-pole, 3-wire
grounding
220-240V
AH363R6W
AH363C6W
AH363P6W
AH363B6W
AH3125R6W
AH3125C6W
AH3125P6W
AH3125B6W
3-pole, 4-wire
grounding
380-415V
AH463R6W
AH463C6W
AH463P6W
AH463B6W
AH4125R6W
AH4125C6W
AH4125P6W
AH4125B6W
4-pole, 5-wire
grounding
220/380
240/415
AH563R6W
AH563C6W
AH563P6W
AH563B6W
AH5125R6W
AH5125C6W
AH5125P6W
AH5125B6W
Receptacle
Pin & Sleeve
20A 2P, 3W
250V AC
Plug
Pin & Sleeve
20A 2P, 3W
250V AC
Receptacle
Pin & Sleeve
20A 2P, 3W
250V AC
Plug
Pin & Sleeve
20A 2P, 3W
250V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Plug
Pin & Sleeve
4P, 5W
3ØY 120/208V AC
Device body:
Single receptacle Plug Connector Flanged inlet
Open shape has holes (receptacles, connectors, outlets)
Closed shape has blades (plugs, inlets)
Locking device legend: How to use the chart
Core catalog number color
indicates a device’s grade:
BLACK = Industrial specification grade
Pin & sleeve configurations
International Standard Amp Rating
Q-12
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
Locking configurations
NEMA AC HP rating Rating
L1-15 0.5 15A-125V
L2-20 2* 20A-250V
L5-15 0.5 15A-125V
L5-20 1 20A-125V
L5-30 2 30A-125V
L6-15 1.5* 15A-250V
L6-20 2* 20A-250V
L6-30 2* 30A-250V
L7-15 2 15A-277V/AC only
L7-20 2 20A-277V/AC only
L7-30 3 30A-277V/AC only
L8-20 3 20A-480V/AC only
L8-30 5 30A-480V/AC only
L9-20 NA 20A-600V/AC only
L9-30 NA 30A-600V/AC only
L10-20 2 L-L*/1 L-N 20A-125/250V
L10-30 2 L-L*/2 L-N 30A-125/250V
L11-15 2 15A-3Ø 250V
L11-20 3 20A-3Ø 250V
L11-30 3 30A-3Ø 250V
L12-20 5 20A-3Ø 480V
L12-30 10 30A-3Ø 480V
L13-30 NA 30A-3Ø 600V
L14-20 2L-L*/1 L-N 20A-125/250V
L14-30 2 L-L*/2 L-N 30A-125/250V
L15-20 3 20A-3Ø 250V
L15-30 3 30A-3Ø 250V
L16-20 5 20A-3Ø 480V
L16-30 10 30A-3Ø 480V
L17-30 NA 30A-3Ø 600V
L18-20 2 20A-3ØY 120/208V
L18-30 3 30A-3ØY 120/208V
L19-20 5 20A-3ØY 277/480V
L19-30 10 30A-3ØY 277/480
L20-20 NA 20A-3ØY 347/600V
L20-30 NA 30A-3ØY 347/600V
L21-20 2 20A-3ØY 120/208V
L21-30 3 30A-3ØY 120/208V
L22-20 5 20A-3ØY 277/480V
L22-30 10 30A-3ØY 277/480V
L23-20 NA 20A-3ØY 347/600V
L23-30 NA 30A-3ØY 347/600V
L-L denotes phase-to-phase HP rating
L-N denotes phase-to-neutral HP rating
*Suitable for 208V motor applications at HP rating
Straight blade configurations
NEMA AC HP rating Rating
1-15 0.5 15A-125V
2-15 1.5* 15A-250V
2-20 2* 20A-250V
2-30 2* 30A-250V
5-15 0.5 15A-125V
5-20 1 20A-125V
5-30 2 30A-125V
5-50 2 50A-125V
6-15 1.5* 15A-250V
6-20 2* 20A-250V
6-30 2* 30A-250V
6-50 3* 50A-250V
7-15 2 15A-277V/AC only
7-20 2 20A-277V/AC only
7-30 3 30A-277V/AC only
7-50 5 50A-277V/AC only
10-20 2L-L*/1 L-N 20A-125/250V
10-30 2 L-L*/2 L-N 30A-125/250V
10-50 3 L-L*/2 L-N 50A-125/250V
11-15 2 15A-3Ø 250V
11-20 3 20A-3Ø 250V
11-30 3 30A-3Ø 250V
11-50 7.5 50A-3Ø 250V
14-15 1.5 L-L*/0.5 L-N 15A-125/250V
14-20 2 L-L*/1 L-N 20A-125/250V
14-30 2 L-L*/2 L-N 30A-125/250V
14-50 3 L-L*/2 L-N 50A-125/250V
14-60 3 L-L*/2 L-N 60A-125/250V
15-15 2 15A-3Ø 250V
15-20 3 20A-3Ø 250V
15-30 3 30A-3Ø 250V
15-50 7.5 50A-3Ø 250V
15-60 10 60A-3Ø 250V
18-15 2 15A-3ØY 120/208V
18-20 2 20A-3ØY 120/208V
18-30 3 30A-3ØY 120/208V
18-50 7.5 50A-3ØY 120/208V
18-60 7.5 60A-3ØY 120/208V
L-L denotes phase-to-phase HP rating
L-N denotes phase-to-neutral HP rating
*Suitable for 208V motor applications at HP rating
Compliances, specifications and availability are subject to change without notice.
Horsepower ratings
NEMA configurations (plugs & receptacles only)
www.eaton.com
www.eaton.com/arrowhart Q-13
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
Common Industry
Information
Q-14
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
NFPA
National Fire Protection Association
The mission of the international non-profit NFPA is to reduce the
worldwide burden of fire and other hazards on the quality of life by
providing and advocating scientifically based consensus codes and
standards, research, training and education. The NFPA authors the
NEC® and NPPA 70E electrical safety in the workplace.
www.nfpa.org
NOM
Normas Oficiales de México (Official Mexican Standards)
The Official Mexican Standards (referred to as Normas or NOMs)
augment the Mexican Hazardous Materials Land Transportation
Regulation and provide information relative to importing and
exporting hazardous materials from and to Mexico.
OSHA
Occupational Health and Safety Administration,
U.S. Department of Labor
OSHAs mission is to assure safe and healthful working conditions
for working men and women (having been authorized to enforce
standards first created under the Occupational Health and Safety
Act of 1970 and since evolved), by assisting and encouraging
the States in their efforts to assure safe and healthful working
conditions.
www.osha.gov
UL
Underwriters Laboratories
Underwriters Laboratories Inc. (UL) is an independent, not-for-
profit product safety testing and certification organization.
www.ul.com
NSF
National Sanitation Foundation
NSF International helps protect people by certifying products
and writing standards for consumer goods. As an independent,
not-for-profit organization, NSF works toward allowing everyone
to live safer.
www.nsf.org
ANSI
American National Standards Institute, Inc.
ANSI is a private, non-profit organization that administers and
coordinates the U.S. voluntary standardization and conformity
assessment system. The Institutes mission is to enhance both the
global competitiveness of U.S. business and the U.S. quality of life
by promoting and facilitating voluntary consensus standards and
conformity assessment systems, and safeguarding their integrity.
www.ansi.org
CSA
Canadian Standards Association
The Canadian Standards Association is a not-for-profit,
membership-based association that conducts product safety
testing, and issues certifications.
www.csa.org
GSA
General Services Administration Federal Supply Service
GSAs Federal Supply Service provides federal customers with a
specific list of manufacturer’s products that have been approved
to meet stated requirements. The most frequently cited Federal
Specifications regarding electrical wiring devices are those for
Electrical Power Connector, Plug, Receptacle and Cable Outlet
(Fed. Spec. W-C 596) and for Toggle and Lock, Flush Mounted
Switches (Fed. Spec. W-S 896).
www.gsa.gov
NEC®
National Electrical Code®
Published by the NFPA (see listing) as NFPA 70, the National
Electrical Code. This publication, renewed every 3 years under the
auspices of ANSI, provides for the adequate protection of life and
property from dangers associated with the use of electricity. It is
now adopted and enforced in all 50 states in the United States,
and is also the basis for electrical codes in several other countries.
www.nfpa.org
NEMA
National Electrical Manufacturers Association
Comprised of electrical manufacturers, NEMA provides a forum
for the standardization and testing of electrical equipment,
enabling consumers to select from a range of safe, effective,
and compatible electrical products. NEMA-standards of testing is
frequently required by both government and third-party endorsees
such as UL and CSA prior to their approval.
www.NEMA.org
Common industry information
Organization abbreviations glossary
Common abbreviations for organizations often referred to in the electrical
industry, and also noted throughout the Arrow Hart catalog
Compliances, specifications and availability are subject to change without notice.
www.eaton.com
www.eaton.com/arrowhart Q-15
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
Standards development organizations
ANSI American National Standards Institute
ASME American Society of Mechanical Engineers
BRC British Retail Consortium
CANENA Consejo de Armonización de Normas Electrotécnicas de Norte América
(Council for Harmonization of Electrotechnical Standardization of North
America)
IEC International Electrotechnical Commission
IEEE Institute of Electrical and Electronics Engineers
ISA Instrument Society of America
ISO International Standards Organization
NFPA National Fire Protection Agency
NSF National Sanitation Foundation
SAE Society of Automotive Engineers
SME Society of Manufacturing Engineers
Certification agencies
ANCE National Association of Normalization and Certification of the
Electrical Sector (Mexico)
BSI British Standards Institute
CCC China Compulsory Certification
CE European Compliance (This is not a certification agency, but CE is the
European Compliance Mark)
CSA Canadian Standards Association
cUL Certified to CSA Standards by Underwriters Laboratories
cULus Meets Canadian & US UL requirements
DESC Defense Electronic Supply Center
ETL Electrical Testing Laboratories
FCC Federal Communications Commission
FM Factory Mutual
IAPA Independent Accident and Protection Association (Canada)
LEED Leadership in Energy and Environmental Design
NRTL National Recognized Testing Laboratories
OSHA Occupational Safety and Health Administration
TUV TUV Rheinland of N.A., Inc.
VDE Verband Deutscher Elektrotechniker (Germany)
UL Underwriters Laboratories
UL standards pertaining to Arrow Hart products
UL20 General-use switches
UL50 Enclosures for electrical equipment
UL94 Flammability testing for materials, plastic
UL486E Equipment and wiring terminals
UL496 Lampholders
UL498 Plugs, connectors, receptacles, inlets, outlets
UL498A Taps and adapters
UL508 Industrial equipment (including motor control switches)
UL514A Metallic boxes/covers/wallplates
UL514D Nonmetallic boxes/covers/wallplates
UL817 Cord sets
UL943 GFCIs
UL1054 Special use switches
UL1363 Temporary power taps
UL1436 Outlet circuit testers
UL1449 Surge suppression devices
UL1472 Dimmers
UL1567 Switches and receptacles used with AL wire
UL1699 Arc fault circuit interrupters
Codes & standards
CEC Canadian Electrical Code
CEE European Electrotechnical Committee
NEC National Electrical Code®
NMX Normas Mexicanas
NOM Normas Oficiales de México (Official Mexican Standard)
Industry associations
ABYC American Boat and Yacht Council
ASHE American Society of Healthcare Engineering
BICSI Building Industry Consulting Services International
BOMA Building Owners Management Association
CANAME Cámara Nacional de Manufacturas Eléctricas (México)
CEMRA Canadian Electrical Manufacturers Representatives Association
ECOC Electrical Contractors of Canada
EFI Electro-Federation Incorporated
EIA Electronics Industry Association
EPRI Electric Power Research Institute
IAEI International Association of Electrical Inspectors
IBI Intelligent Building Institute
IECA Independent Electrical Contractors Association
IFMA International Facilities Management Association
NAED National Association of Electrical Distributors
NAW National Association of Wholesalers
NECA National Electrical Contractors Association
NEMA National Electrical Manufacturers Association
NEMRA National Electrical Manufacturers Representative Association
NMDA National Marine Distributor Association
NMRA National Marine Representative Association
SEMI Semi-Conductor Equipment and Material International
TIA Telecommunications Industry Association
USGBC US Green Building Council
Codes & standards
UL1786 Night-lights
UL1863 Communications circuit accessories
UL1917 Solid state fan speed control
FSWC596 Fed. Spec. receptacles
FSWS896 Fed. Spec. switches
Industry associations
C22.2 No. 0.17 Polymeric materials
C22.2 No. 12 Night lights
C22.2 No. 42 General-use receptacles, attachment plugs
C22.2 No. 55 Special-use switches
C22.2 No. 111 General-use switches
C22.2 No. 144 GFCI
C22.2 No. 182.1 Industrial-type, special-use attachment plugs, receptacles and
connectors. Pin and sleeve devices
C22.2 No. 182.2 Industrial locking type
NFPA
National Fire Protection Association
The mission of the international non-profit NFPA is to reduce the
worldwide burden of fire and other hazards on the quality of life by
providing and advocating scientifically based consensus codes and
standards, research, training and education. The NFPA authors the
NEC® and NPPA 70E electrical safety in the workplace.
www.nfpa.org
NOM
Normas Oficiales de México (Official Mexican Standards)
The Official Mexican Standards (referred to as Normas or NOMs)
augment the Mexican Hazardous Materials Land Transportation
Regulation and provide information relative to importing and
exporting hazardous materials from and to Mexico.
OSHA
Occupational Health and Safety Administration,
U.S. Department of Labor
OSHAs mission is to assure safe and healthful working conditions
for working men and women (having been authorized to enforce
standards first created under the Occupational Health and Safety
Act of 1970 and since evolved), by assisting and encouraging
the States in their efforts to assure safe and healthful working
conditions.
www.osha.gov
UL
Underwriters Laboratories
Underwriters Laboratories Inc. (UL) is an independent, not-for-
profit product safety testing and certification organization.
www.ul.com
NSF
National Sanitation Foundation
NSF International helps protect people by certifying products
and writing standards for consumer goods. As an independent,
not-for-profit organization, NSF works toward allowing everyone
to live safer.
www.nsf.org
Common industry information
Organization acronyms
Common UL & CSA standards for wiring devices
Compliances, specifications and availability are subject to change without notice.
Q-16
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
Article 210 – Branch circuits
210.8 Ground-fault circuit-interrupter protection for personnel
210.21 Branch circuit ratings, outlet devices
210.24 Branch circuit requirements - summary
210.50 Required outlets, general
210.60 Required outlets, guest rooms, guest suites, dormitories
and similar occupancies
210.62 Required outlets, show windows
210.70 Lighting outlets required
Article 404 – Switches
404.2 Installation, switch connections
404.3 Installation, enclosure
404.4 Installation, damp or wet locations
404.9 Installation, provisions for general-use snap switches
404.14 Rating and use of snap switches
404.15 Construction specifications, marking
Article 406 — Receptacles, cord connectors
& attachment plugs (caps)
406.3 Receptacle rating and type
406.4 General installation requirements
406.5 Receptacle mounting
406.6 Receptacle faceplates (cover plates)
406.7 Attachment plugs, cord connectors and flanged surface devices
406.8 Noninterchangeability
406.9 Receptacles in damp or wet locations
406.10 Grounding-type receptacles, adapters, cord connectors and
attachment plugs
406.12 Tamper-resistant receptacles in dwelling units
Article 430 — Motors, motor circuits & controllers
430.8 Marking on controllers
430.81 Motor controllers, general
430.82 Motor controllers, controller design
430.83 Motor controllers, ratings
430.90 Combination fuseholder and switch as controller
430.102 Disconnecting means, location
430.109 Disconnecting means, type
Article 517 – Health care facilities
517.2 Definitions
517.10 Wiring and protection, applicability
517.13 Grounding of receptacles and fixed electrical equipment in patient
care areas
517.14 Panelboard bonding
517.16 Use of isolated ground receptacles
517.17 Ground-fault protection
517.18 Wiring and protection, general care areas
517.19 Wiring and protection, critical care areas
517.20 Wiring and protection, wet procedure locations
517.21 Ground-Fault-Circuit-Interrupter protection for personnel
517.30 Essential electrical systems for hospitals
517.31 Branches requiring automatic connection
517.35 Sources of power
517.40 Essential electrical systems for nursing homes and limited care facilities
517.41 Essential electrical systems (nursing homes, etc.)
517.45 Essential electrical systems for other health care facilities
517.61 Inhalation anesthetizing locations, wiring and equipment
517.62 Inhalation anesthetizing locations, grounding
517.63 Grounded power systems in anesthetizing locations
517.64 Inhalation anesthetizing locations, low-voltage equipment
and instruments
517.71 X-ray installations connection to supply circuit
517.72 X-ray installations disconnecting means
517.160 Isolated power systems
Article 555 – Marinas & boatyards
555.1 Scope
555.13 Wiring methods and installations
555.19 Receptacles (including GFCI)
Article 590 — Temporary installations
590.4 General (including receptacles and GFCI)
Article 604 — Manufactured wiring systems
604.2 Definition
604.6 Construction (including receptacles and connectors)
Article 630 — Electric welders
630.13 Arc welders, disconnecting means
630.33 Resistance welders, disconnecting means
Article 647 — Sensitive electronic equipment
647.7 Receptacles (including isolated ground receptacles)
Article 660 — X-ray equipment
660.4 Connection to supply circuit
660.5 Disconnecting means
Article 700 — Emergency systems
700.27 Overcurrent protection, ground-fault protection of equipment
Compliances, specifications and availability are subject to change without notice.
Common industry information
Selected articles, National Electric Code (NEC®) requirements for
wiring devices from NFPA 70™, NEC® 2014 Edition
www.eaton.com
www.eaton.com/arrowhart Q-17
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
Diameter ranges of jacketed cord in accordance with standard UL62
Acceptable range for overall diameter of jacketed cord
Type of cord Avg. size 2-Conductor 3-Conductor 4-Conductor 5-Conductor
SV, SVO, SVT SVTO 18 0.22"-0.26"
(5.6mm-6.6mm)
0.23"-0.27"
(5.8mm-6.9mm)
— —
SJ, SJE, SJO, SJOO,
SJEO, SJEOO, SJT,
SJTO, SJTOO, SJEW,
SJEOW, SJEOOW,
SJTW, SJTOW,
SJTOOW
18 0.28"-0.32"
(7.1mm-8.1mm)
0.30"-0.34"
(7.6mm-8.6mm)
0.33"-0.37"
(8.4mm-9.4mm)
16 0.31"-0.34"
(7.9mm-8.6mm)
0.33"-0.36"
(8.4mm-9.1mm)
0.35"-0.40"
(8.9mm-10.2mm)
14 0.34"-0.38"
(8.6mm-9.7mm)
0.36"-0.40"
(9.1mm-10.2mm)
0.39"-0.44"
(9.9mm-11.2mm)
12 0.41"-0.46"
(10.4mm-11.7mm)
0.43"-0.48"
(10.9mm-12.2mm)
0.47"-0.52"
(11.9mm-13.2mm)
10 0.54"-0.61"
(13.7mm-15.5mm)
0.57"-0.64"
(14.5mm-16.3mm)
0.63"-0.70"
(16.0mm-17.8mm)
S, SE, SOO, SEO,
SEOO, ST, STOO, STO,
SEW, SOOW, SOW,
SEOW, SEOWW,
STW, STOOW, STOW
18 0.34"-0.39"
(8.6mm-9.9mm)
0.36"-0.40"
(9.1mm-10.2mm)
0.39"-0.43"
(9.9mm-10.9mm)
0.46"-0.51"
(11.7mm-13.0mm)
16 0.37"-0.41"
(9.4mm-10.4mm)
0.39"-0.43"
(9.9mm-10.9mm)
0.41"-0.46"
(10.4mm-11.7mm)
0.49"-0.55"
(12.4mm-14.0mm)
14 0.50"-0.55"
(12.7mm-14.0mm)
0.52"-0.58"
(13.2mm-14.7mm)
0.56"-0.62"
(14.2mm-15.7mm)
0.63"-0.71"
(16.0mm-18.0mm)
12 0.57"-0.63"
(14.5mm-16.0mm)
0.59"-0.66"
(15.0mm-16.8mm)
0.64"-0.71"
(16.3mm-18.0mm)
0.70"-0.77"
(17.8mm-19.6mm)
10 0.62"-0.69"
(15.7mm-17.5mm)
0.65"-0.72"
(16.5mm-18.3mm)
0.70"-0.78"
(17.8mm-19.8mm)
0.76"-0.84"
(19.3mm-21.3mm)
8 0.78"-0.88"
(19.8mm-22.4mm)
0.83"-0.93"
(21.1mm-23.6mm)
0.93"-1.05"
(23.6mm-26.7mm)
1.00"-1.15"
(25.4mm-29.2mm)
6 0.92"-1.05"
(23.4mm-26.7mm)
0.97"-1.10"
(24.6mm-27.9mm)
1.05"-1.20"
(26.7mm-30.5mm)
1.18"-1.33"
(30.0mm-33.8mm)
4 1.06"-1.21"
(26.9mm-30.7mm)
1.13"-1.28"
(28.7mm-32.5mm)
1.25"-1.45"
(31.8mm-3.8mm)
2 1.21"-1.40"
(30.7mm-35.6mm)
1.30"-1.50"
(33.0mm-38.1mm)
1.45"-1.65"
(36.8mm-41.9mm)
Key
EThermoplastic elastomer SExtra hard usage (600V) VVacuum (typically used for portable cleaning
equipment)
OOil resistant outer jacket SJ Junior hard usage (300V)
OO Oil resistant outer jacket & oil resistant insulation TThermoplastic/vinyl WWeather & water resistant for damp
& wet locations
PParallel
Examples
SEOOW Extra hard usage thermoplastic elastomer with oil resistant outer jacket
and insulation; approved for outdoor use and water resistance; 600V up
to 105ºC.
SJT Hard usage thermoplastic rubber-insulated conductors
and overall thermoplastic jacket. 300V up to 105ºC.
SJTW Hard usage thermoplastic or rubber-insulated conductors and overall
thermoplastic jacket. 300V up to 105ºC.
Weather resistant for outdoor use.
SPT-1 All thermoplastic construction, parallel jacketed.
300V up to 105ºC, 2 or 3-conductor (18 gauge).
SPT-2 Same as SPT-1, but heavier construction (18-16 gauge).
SPT-3 Same as SPT-2, but heavier construction (18-10 gauge).
SRDT Portable range or dryer cable, 3-conductor parallel type or 4 insulated
conductors, jacketed. All thermoplastic construction. 300V, maximum
temperature of 60ºC.
HPN Two-conductor, neoprene-insulated heater cord. Parallel construction.
For use in damp locations. 300V, 90ºC.
Compliances, specifications and availability are subject to change without notice.
Wire and cable information
Wire & cable type abbreviations
Q-18
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
2 -pole, 2-wire non-grounding: 125V
2-pole, 3-wire grounding: 125V
2-pole, 3-wire grounding: 277V AC
3-pole, 3-wire non-grounding: 125/250V
3-pole, 4-wire grounding: 125/250V
2-pole, 2-wire non-grounding: 250V
2-pole, 3-wire grounding: 250v
2-pole, 3-wire grounding: 480V/AC
3-pole, 3-wire non-grounding: 3Ø 250V
3-pole, 4-wire grounding: 3Ø 250V
Compliances, specifications and availability are subject to change without notice.
Wiring diagrams (by NEMA configurations)
www.eaton.com
www.eaton.com/arrowhart Q-19
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
3-pole, 4-wire grounding: 3Ø 480V
4-pole, 4-wire non-grounding: 3Ø 120/208V
4-pole, 4-wire non-grounding: 3Ø 347/600V
4-pole, 5-wire grounding: 3Ø 277/480V
3-pole, 4-wire grounding: 3Ø 600V
4-pole, 4-wire non-grounding: 3Ø 277/480V
4-pole, 5-wire non-grounding: 3Ø 120/208V
4-pole, 5-wire grounding: 3Ø 347/600V
Compliances, specifications and availability are subject to change without notice.
Wiring diagrams (by NEMA configurations) Wiring diagrams (by NEMA configurations)
Q-20
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
GFCI: Feed-through installation with protection provided
downstream
GFCI: Feed-through installation with both protected &
non-protected receptacles downstream
Single-pole switch and neon pilot light
No. 277
23
23
Single-pole switch & 2-pole, 3-wire
U grounding receptacle
Cat. No. 274
15A-125V
GFCI: Feed-through installation with
non-protected receptacles downstream
2 Single-pole switches
No. 271
Single-pole switch & 2-pole, 3-wire 20A
U grounding receptacle
No. 291
Combination devices wiring diagrams
Receptacles wiring diagrams
Compliances, specifications and availability are subject to change without notice.
Wiring diagrams (receptacles & combination devices)
www.eaton.com
www.eaton.com/arrowhart Q-21
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
Pilot light switch & lighted switch, 3-way
Maintained & momentary contact, double-pole
Pilot light switch & lighted switch, single & double pole
Maintained & momentary contact, single-pole
Maintained
Contact
3-Position,
2-Circuit
Center “Off”
Momentary
Contact Either
Direction
3-Position,
Center “Off”
Maintained
Contact Either
Direction
2-Position,
No Center “Off”
Manual contactors & disconnect switches
AH4361, AH4371 DPDT
Momentary Contact,
2-Circuit With Center
“Off” Switch
On–Off–On
2-Phase Circuit
L1L2
L
L
1T11
T2
2T12
T2
AH4361, AH4371, AH4357 DPDT
Momentary Contact,
2-Circuit With Center
“Off” Switch
On–Off–On
2-Phase Circuit
L1L2
L
L
1T11
T2
2T12
T2
AH4354 SPDT
Momentary Contact,
2-Circuit With Center
“Off” Switch
Mom. On–Off–Mom. On
2-Phase Circuit
N
L
L
L1
AH4356 SPDT
Maintained Contact,
2-Circuit With Center
“Off” Switch
On–Off–On
2-Phase Circuit
N
L
L
L1
AH4355 DPDT
Momentary Contact,
2-Circuit With Center
“Off” Switch
Mom. On–Off–Mom. On
2-Phase Circuit
L
L
L1N
AH4357 DPDT
Maintained Contact,
2-Circuit With Center
“Off” Switch
On–Off–On
2-Phase Circuit
L
L
L1N
AH4361, AH4371 DPDT
Momentary Contact,
2-Circuit With Center
“Off” Switch
On–Off–On
Single Phase Circuit
L1N
L
L
AH4361, AH4371 DPDT
Momentary Contact,
2-Circuit With Center
“Off” Switch
On–Off–On
Single Phase Circuit
L1N
L
L
OLD DRAWINGS DO NOT USE
AC switches & standard switches
Switches wiring diagrams
Wiring diagrams (switches)
Compliances, specifications and availability are subject to change without notice.
Wiring diagrams (receptacles & combination devices)
Single-Pole Double-Pole 3-Way to 3-Way 3-Way 4-Way 3-Way
Single-Pole Pilot Light
Switch - Toggle Glows
When Switch is On
Single-Pole Lighted Toggle
Switch - Toggle Glows
When Switch is Off
Double-Pole Pilot Light
Switch - Toggle Glows
When Switch is On
3-Way Lighted Switch 3-Way Pilot Lighted Switch
Single-Pole
Double Throw
Single-Pole
Double Throw
Single-Pole
Double Throw
On-Off-On
2-Phase Circuit
On-Off-On
Single Phase Circuit
Double-Pole
Double Throw
Center Off
Double-Pole
Double Throw
Center Off
Double-Pole
Double Throw
No Center Off
Q-22
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
Capacitor Two Windings
Diagram 1
L1
T2T4
T1T3
L1L2
L2
HIGH
OFF
LOW
FORWARD
OFF
REVERSE
Repulsion Induction
Diagram 2
L1
L2
T2T4
T1T3
L1L2
T8T5
T1T4
FORWARD
OFF
REVERSE
Series
Diagram 3
L1
L2
T2T4
T1T3
L1L2
A2A1
S1S2
Capacitor Consequent Pole
Diagram 4
L1
T2T4
T1T3
L1L2
L2
HIGH
OFF
LOW
T4
T2
T5
T2
T1
Diagram 4 Internal Connections
HIGH
LOW
L1
T2
&
L1
T1
&
L2 & T3
&
T4
L2 to T2
&
T3
Capacitor
Diagram 5
L1
T2T4
T1T3
L1L2
L2
FORWARD
OFF
REVERSE
T4
T1
T8
T5
Diagram 5 & 6
Internal Connections
REVERSE
FORWARD
T1
T2
&
T3
T4
&
T1
T4
&
T3
T2
&
L1L2
Split Phase
Diagram 6
L1
T2T4
T1T3
L1L2
L2
FORWARD
OFF
REVERSE
T4
T1
T8
T5
3-Phase Separate Winding
Diagram 7
L1
L2
L3
HIGH
OFF
LOW
T2T3
T1
T12 T13
T11
3-Phase Induction
Diagram 8
L1
L2
L3
FORWARD
OFF
REVERSE
T2
T3
T1
Series DC
Diagram 9
L1
L2
FORWARD
OFF
REVERSE
S2
S1A1A2
Shunt DC
Diagram 10
L1
L2
FORWARD
OFF
REVERSE
F2
F1
A1A2
Compound DC
Diagram 11
L1
L2
FORWARD
OFF
REVERSE
F2
F1
A1A2
S1S2
2-Phase Separate Winding
Diagram 12
L1
L2
L4
L3
HIGH
OFF
LOW
T1T2T3T4
T11 T12 T13 T14
A
B
Ø
Ø
2-Phase Induction
Diagram 13
L1
L2
L4
L3
FORWARD
OFF
REVERSE
T1T2T3T4
A
B
Ø
Ø
Wiring diagrams
(manual contacts & disconnect switches, by motor variations)
Compliances, specifications and availability are subject to change without notice.
Motor variations wiring diagrams
www.eaton.com
www.eaton.com/arrowhart Q-23
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
AH6808UDAC, AH6808UCO
ON
1.38" 1.04" 1.31"
2.22"
3.28"
4.06"
2.38"
(60.4mm)
(35.0mm)
(83.3mm)
(103.1mm)
(26.4mm)
(56.4mm)
(33.3mm)
AHMC240L, AHMC340L, AHMC260L, AHMC360L
.06"
#4-#14 Wire
Box Lugs Accept
2.31"
1.66"
Mtg. Holes
(2)#6/32"Tap
ON
OFF 3.28"
2.38"
(2).22 Dia.
1.74"
3.75"
(58.7mm) (95.3mm)
(42.2mm)
(1.5mm)
(44.2mm)
(60.5mm)
(83.3mm)
(5.6mm)
(4.8mm)
AH4361, AH4371
3.78"
3.28"
Holes
ACB
D
(2) .20"
(96.0mm)
(83.3mm)
(5.1mm)
A B C D
AH4361 1.59"
(40.4mm)
1.66"
(42.2mm)
0.66"
(16.8mm)
2.50"
(63.5mm)
AH4371 1.81"
(46.0mm)
1.98"
(50.3mm)
1.22"
(31.0mm)
2.88"
(73.2mm)
AH6810U, AH7810UD
Tap
#6/32"
OFF
2.38"
3.28"
1.69"
2.31"
3.81"
1.75"
(42.9mm) (44.5mm)
(96.8mm)
(83.3mm)
(60.4mm)
(4.7mm)
(58.7mm)
AHMC240C, AHMC340C
.06"
Clamps Accept
#8-#14 Wire
2.31"
1.66"
2.38"
(2)#6/32 Tap
OFF
ON
3.28"
Mtg. Holes
(2).22" Dia.
2.23"
3.75"
(42.2mm)
(1.5mm)
(58.7mm)
(95.3mm)
(5.6mm)
(56.6mm)
(83.3mm)
(60.5mm)
Dimensional data (switches)
Compliances, specifications and availability are subject to change without notice.
Q-24
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
AH6810E, AH7810ED
6.75"
2.63"
5.88"
3.50" 4.75"
.34"
.75" Hub
(120.7mm)
(8.6mm)
(88.9mm)
(171.5mm)
(66.8mm)
(19.1mm)
(149.4mm)
AH6808WDAC
ON
OFF
3.43"
2.75"
5.81"
.75" Hub
(147.6mm)
(69.9mm) (87.1mm)
(19.1mm)
AHN3WD, AH6808WDAC, AH6810W, AHMC240C-3,
AHMC240L-2, AHMC260L-3, AHMC340C-3, AHMC340L-2,
AHMC360L-2
ON
F
(2).25" (6.35mm) Dia.
Embossed Mtg. Hole
MANUAL MOTOR CONTROLLER
4.50"
6.00"
4.00"
2.50" 1.50"
3.00"
(152.4mm)
(114.3mm)
(101.60mm)
(76.2mm)
(38.10mm)
(63.50
mm)
ON
F
(2).25" (6.35mm) Dia.
Embossed Mtg. Hole
MANUAL MOTOR CONTROLLER
4.50"
6.00"
4.00"
2.50" 1.50"
3.00"
(152.4mm)
(114.3mm)
(101.60mm)
(76.2mm)
(38.10mm)
(63.50
mm)
ON
F
(2).25" (6.35mm) Dia.
Embossed Mtg. Hole
MANUAL MOTOR CONTROLLER
4.50"
6.00"
4.00"
2.50" 1.50"
3.00"
(152.4mm)
(114.3mm)
(101.60mm)
(76.2mm)
(38.10mm)
(63.50
mm)
AHMC360L-1, AHMC260L-1, AH781OGD, AHMC340C-1,
AHMC340L-1, AH6808GDAC, AH6810G, AHMC240C-1,
AHMC240L-1, AH27940G, AHN1GD
1/2" (12.70mm) Conduit KO Centered on Back
2.50"
Shroud Accepts up to
5/16" (7.9mm) Dia. Lock Shank
2.63"
3.00"
4.25"
(3).25" (6.4mm) Dia. Hole
Ground Screw
1.38"(35.1mm)
MANUAL MOTOR STARTER
2.92"
OFF
(74.2mm)
(108.0mm)
(63.5mm)
(66.8mm)
(76.2mm)
AH7810GDB, AHN1GD2 AHN1GD2D
Dim A=2.63" (66.80mm) Dim A=3.87" (98.30mm)
4.67"
OFF
Shroud Accepts up to
5/16" Dia. (7.9mm) Lock Shank
#14-#4
Ground Lug
'A'
4.42" 4.25"
1.37"
1.50" (38.1mm)
(3).25 (6.4mm) Mtg. Hole
Conduit (5 Plc.'s)
Knockouts for
.75 - 1.00
2.00" (50.8mm)
(118.6mm)
(112.3mm)
(108.0mm)
(34.8mm)
(19.05-25.4mm)
AH6808FDAC (plate only, no toggle guard) AH7810FD
MANUAL MOTOR CONTROLLER
C
OFF
1.68"
.19"
2.31"
2.75"
4.50"
(114.3mm)
(69.9mm)
(58.7mm)
(42.7mm)
(4.8mm)
Dimensional data (enclosures)
Compliances, specifications and availability are subject to change without notice.
www.eaton.com
www.eaton.com/arrowhart Q-25
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
Attachon lampholder cutouts
Panel Cutout
732-3
0.34"
(8.6mm)
1.41"
(35.8mm)
1.53"
(38.86mm)
4734-2
2.13"
(54.1mm)
0.188"
(4.8mm) 1.38"
(34.8mm)
734
1.8"
(46.0mm)
1.38"
(34.8mm)
Dia.
0.188"
(4.8mm)
Diam.
Panel Cutout
Panel Cutout
Panel Cutout
732-3
0.34"
(8.6mm)
1.41"
(35.8mm)
1.53"
(38.86mm)
4734-2
2.13"
(54.1mm)
0.188"
(4.8mm) 1.38"
(34.8mm)
734
1.8"
(46.0mm)
1.38"
(34.8mm)
Dia.
0.188"
(4.8mm)
Diam.
Panel Cutout
Panel Cutout
0.90"
(22.8mm)
Dia.
1.03"
(26.0mm)
0.425"
(10.8mm)
0.82"
(20.8mm)
0.063"
(1.6mm)
0.125"
(3.2mm)
Panel Cutout
731-2, 731-3
Panel Cutout
Dimensional data (cutouts)
Compliances, specifications and availability are subject to change without notice.
Snap-in receptacle panel cutouts
Panel Cutout
49
Panel Cutout
732-3
Panel Cutout
731-2, 731-3
Panel Cutout
974-2
Panel Cutout
734
Panel Cutout
4734-2
Panel Cutout
67
Q-26
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
Test requirements - switches general use - AC only
Rating Standard
Overload Endurance
Resistance cycles
1.0 pf.
Inductive cycles
.75 to .8 pf.
Tungsten cycles
1.0 pf.
Amps Volts Power factor Cycles Amps
Volts
(Max)
15A,
120V/AC
UL20 72 120 AC .4 to .5 100 15 120 AC 10,000 10,000 10,000
WS 896 72 120 AC .4 to .5 100 15 120 AC 10,000 50,000 50,000
15A
120/277
277V/AC
UL20 72 277 AC .4 to .5 100 15 277 AC 10,000 10,000 10,000
WS 896 72 277 AC .4 to .5 100 15 277 AC 10,000 50,000 50,000
20A,
120/277
277V/AC
UL20 96 277 AC .4 to .5 100 20 277 AC 10,000 10,000 10,000
WS 896 96 277 AC .4 to .5 100 20 277 AC 10,000 50,000 50,000
20A,
120/277
277V/AC
UL20 144 277 AC .4 to .5 100 30 277 AC 10,000 10,000 10,000
WS 896 144 277 AC .4 to .5 100 30 277 AC 10,000 50,000 50,000
General Use AC switches are suitable for use at full rated current and voltage on loads of fluorescent and
incandescent lighting and for other inductive or resistance loads. Our switches are rated for motor loads at 80%
of their rated current.
Special Use AC switches may be used at full rating on resistance or inductive loads, including fluorescent. For
incandescent (tungsten) lighting loads, they must carry an “L” rating. For motor loads they require an “HP”
(horsepower) rating.
To ensure safety and reliability, Arrow Hart switches are tested, rated and marked according to various standards.
The following charts indicate both the required performance tests specified by industry standards for switches
with standard ratings, and the loads they may control.
WS896 is current Federal Specification. All switches are subjected to resistive endurance, inductive endurance,
tungsten endurance and then verified that they meet less than a 86ºF
(30ºC) temperature rise at rated current and voltage, followed by a
dielectric test at 1500 V/AC for 1 minute.
† Power Factor
Test requirements - switches special use - AC only
Rating Standard
Overload Endurance Horse power “L” Tungsten
Amps Volts
Power
factor Cycles Amps Volts
Power
factor Cycles Amps Volts
Power
factor Cycles Amps Volts Cycles
8A, 120V/AC UL1054 12 120 AC .4-.5 50 8 120 AC .75-.8 6000
15A, 120V/AC
10A, 240V/AC
3/4 HP,
120-240V/AC
UL1054 15 240 AC .4-.5 50 10 240 AC .75-.8 6000 82.8 120 AC .4-.5 50
41.4 240 AC .4-.5 50
15A,
125-250V/AC
3/4 HP,
120-240V/AC
UL1054 22.5 250 AC .4-.5 50 15 250 AC .75-.8 6000 82.8 120 AC .4-.5 50
41.4 240 AC .4-.5 50
20A, 125V/AC “L”
20A, 250V/AC
1 HP,
120-240V/AC
UL1054 30 240 AC .4-.5 50 20 250 AC .75-.8 6000 96 120 AC .4-.5 50 20 125 AC 6000
48 240 AC .4-.5 50
Compliances, specifications and availability are subject to change without notice.
Switch applications
Test requirements
The maximum permitted load for which a switch is suitable depends on the switch rating
and the nature of the load. Proper selection of switches is determined by test standards and
requirements of the National Electrical Code®, Articles 380, 430, and 600.
www.eaton.com
www.eaton.com/arrowhart Q-27
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
Maximum loads - switches - general use - AC only
Switch rating
Incandescent Inductive (fluorescent) Resistance Motors
Volts Amps Volts Amps Volts Amps Volts HP Amps
15A, 120V/AC 120 AC 15 120 AC 15 120 AC 15 120 AC 1/2 12
20A, 120V/AC 120 AC 20 120 AC 20 120 AC 20 120 AC 1 16
15A, 120/277V/AC 120 AC 15 277 AC 15 277 AC 15 120 AC 1/2 12
240 AC 1 12
20A, 120/277V/AC 120 AC 20 277 AC 20 277 AC 20 120 AC 1 16
240 AC 2 16
30A, 120/277V/AC 120 AC 30 277 AC 30 277 AC 30 120 AC 2 24
240 AC 2 24
Maximum loads - switches - special use - AC only
Switch rating
Incandescent Inductive (fluorescent) Resistance Motors
Volts Amps Volts Amps Volts Amps V/AC HP Amps
8A, 120V/AC
15A, 120V/AC Not suitable 120 AC 8 120 AC 8 Not suitable
120 AC 15 120 AC 15
10A, 240V/AC
3/4HP, 120/240V/AC Not suitable 250 AC 10 240 AC 10 240V/AC 3/4 12
15A, 120-240V/AC
3/4HP, 120/240V/AC Not suitable 250 AC 15 250 AC 15 240V/AC 3/4 12
20A,120V/AC “L”
20A, 250V/AC
1HP, 120/240V/AC
125 AC 20 250 AC 20 250 AC 20 240V/AC 1 12
Compliances, specifications and availability are subject to change without notice.
Switch applications
Maximum loads
Q-28
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
Materials Acids Alcohol
Caustic
bases Gasoline Grease Kerosene Oil Solvents Water
Nylon
(Thermoplastic) 3 1 1 1 1 1 1 1 1
Polycarbonate
(Thermoplastic) 2 1 3 2 2 2 2 3 1
302/304
Stainless steel 2 1 3 1 1 1 1 2 1
Polyvinyl
Chloride (PVC) 1 1 1 1 1 1 1 3 1
Polypropylene
(Thermoplastic) 1 1 1 1 1 1 1 2 1
Polyester 1 1 2 1 1 1 1 2 1
Rubber
(Thermoplastic) 2 2 3 2 2 1 1 3 2
Phenolic
(Thermoset) 2 1 2 1 1 1 1 1 1
ABS
(Thermoplastic) 2 2 1 1 1 2 2 3 1
Chemical resistance factor
1 – Completely resistant — good to excellent for general use when exposed to these factors.
2 – Resistance is fair to good — recommended for limited service when exposed to these factors.
3 – Slow attack. Not recommended for use when exposed to these factors.
*The chemical resistance factor represents general applications. Additional testing is required to determine resistance to chemicals in specific environments.
Key terms describing material enhancements
Thermoplastic: Material treated for UV stability to increase tensile strength and decrease discoloration when exposed to UV radiation. Manufactured by injection molding.
Superior resistance to impacts, chemical and solvent attack.
Thermoset: Flame resistant material with dimensional stability. Manufactured by compression molding.
Glass filled: Glass-filled material (most commonly nylon) yields increased material rigidity and permits operation at a higher temperature.
Nickel plated: Plating of steel or brass with nickel to increase the corrosion-resistant properties of the metal component.
Zinc plated: Plating of cold-rolled steel with zinc to increase the corrosion-resistant properties of the metal component or casing.
Switch applications or materials
Chemical resistant properties of common materials in wiring devices
Compliances, specifications and availability are subject to change without notice.
www.eaton.com
www.eaton.com/arrowhart Q-29
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
Protection from
Device locations
Indoors
Indoors or
outdoors
Outdoors with
external mechanisms
Limited amounts of falling dirt NEMA type 1
Limited amounts of falling dirt and dripping water NEMA type 2
Rain, sleet, falling dirt, windblown dust, damage from ice formation NEMA type 3
Rain, sleet, falling dirt, damage from ice formation NEMA type 3R
Rain, sleet, windblown dust, ice laden operation possible NEMA type 3S
Windblown dust and rain, splashing water, hose-directed water,
damage from ice formation NEMA type 4
Corrosion, windblown dust and rain, splashing water, hose-directed water,
damage from ice formation NEMA type 4X
Falling dirt and settling airborn dust, lint, fibers and dripping non-corrosive liquids NEMA type 5
Hose-directed water, entry of water during occasional short-term
limited depth submersion, damage from ice formation NEMA type 6
Hose-directed water, entry of water during long-term limited depth submersion,
damage from ice formation NEMA type 6P
Class I, Division 1, groups A,B,C or D hazardous locations
(as defined by NEC®, NFPA 70)
NEMA type 7
(commonly referred to
as explosion-proof)
Class I, Division 1, groups A,B,C or D hazardous locations
(as defined by NEC®, NFPA 70)
NEMA type 8
(commonly referred to
as oil-immersed)
Class II, Division 1, groups E, F and G hazardous locations
(as defined by NEC®, NFPA 70)
NEMA type 9
(commonly referred to
as dust-ignition-proof)
Meets applicable requirements of the Mine Safety & Health Administration,
30 CFR, part 18 NEMA type 10
Circulating dust, falling dirt, dripping non-corrosive liquids NEMA type 12
NEMA type 12K
Dust, spraying of water, oil and non-corrosive coolant NEMA type 13
IP enclosure ratings
Second digit - protection against
penetration of liquids IP_0 IP_1 IP_2 IP_3 IP_4 IP_5 IP_6 IP_7 IP_8
First digit -
protection
against
persons -
touching
& ingress of
solid objects
Non-
protected
Vertical
falling of
water drops
Falling of
water drops
at angle up
to 15º from
vertical
Spraying
water (rain)
at angle up
to 60º from
vertical
Splashing
water
from any
direction
(360º)
Water jets
from any
direction
(360º)
Power
jetting water
Temporary
immersion in
water
Continuous
immersion in
water
IP0_ Without protection IP00
IP1_ Touching with hand & solid objects
> 50mm dia. IP10 IP11 IP12
IP2_ Touching with finger & solid objects
> 12mm dia. IP20 IP21 IP22 IP23
IP3_ Touching with tools, wires, etc.
> 2.5mm thick & solid objects
> 2.5mm dia.
IP30 IP31 IP32 IP33 IP34
IP4_ Touching with tools, wires, etc.
> 1mm thick & solid objects
> 1mm dia.
IP40 IP41 IP42 IP43 IP44
IP5_ Unlimited protection against
contact with live parts &
damaging dust deposits
IP50 IP54 IP55
IP6_ Unlimited protection against contact
with live parts & any dust penetration IP60 IP65 IP66 IP67 IP68
NEMA & IP enclosure ratings
NEMA enclosure ratings
Compliances, specifications and availability are subject to change without notice.
Q-30
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION UNDERWRITERS LABORATORIES UL50
NEMA Standards publication no.250-1991, enclosures for electrical equipment (1000V max.) Standard for enclosures for
electrical equipment (10th Edition)
Intended use and description Intended use and description
An enclosure is a surrounding case that provides personnel with protection against incidental contact with enclosed
equipment, and simultaneously protects enclosed equipment against specific environmental conditions.
An enclosure is a surrounding case that protects
equipment enclosed within against incidental contact,
as well as specific environmental conditions. A complete
enclosure shall be provided for all live parts that may be
housed in it. Such an enclosure shall be tight and come
with a means for mounting, unless it’s designed for a
special installation, for example, a cast metal junction or
pull-box intended for installation in poured concrete.
Type 1 Type 5
Enclosures are intended for indoor use primarily to
protect against limited amounts of falling dirt.
Enclosures used primarily indoors to provide protection
against airborne dust and dirt, and non-corrosive liquids.
Type 2 Type 6 Type 1
Enclosures provide a degree of protection, mainly
indoors, against limited amounts of dripping water or
falling dirt.
Enclosures provide protection both indoors and out
against hose-directed water, water entry during
occasional short-term submersion at low-pressure
depths, and damage caused by exterior ice formation.
Enclosures are intendedfor indooruseprimarilyto
protect againstlimited amountsoffallingdirt.
Type 3 Type 6P Type 2
Enclosures, intended primarily for use outdoors, protect
against rain, sleet, wind-blown dust, and damage from
external ice formation.
Enclosures protect both indoors and out against
hose-directed water, water entry during long-term
submersion at low-pressure depths, and ice damage.
Enclosures provide a degree of protection, mainly
indoors, against limited amounts of dripping water or
falling dirt.
Type 3R Type 12 Type 3
Enclosures provide protection primarily against rain,
sleet, and damage from external ice formation.
Enclosures used primarily indoors to protect against
airborne dust or dirt, and non-corrosive liquids.
Enclosures, intended primarily for use outdoors, protect
against rain, sleet, wind-blown dust, and damage from
external ice formation.
Type 3S Type 12K Type 3R
Enclosures protect primarily against rain, sleet, and
wind-blown dust, and enable external mechanisms to
operate efficiently even when ice laden.
Enclosures with knockouts are used primarily indoors
for protection against airborne dust and dirt, and non-
corrosive liquids.
Used primarily outdoors for protection against rain,
sleet, and exterior damage caused by the formation
of ice.
Type 4 Type 13 Type 3S
Enclosures provide protection, both indoors and out,
against wind-blown dust and rain, splashing or hose-
directed water, and ice damage.
Enclosures used primarily indoors to protect against
dust, as well as accidental spraying by water, oil, or
non-corrosive coolants.
Used primarily outdoors for protection against rain,
sleet, and wind-blown dust, and to enable exterior
mechanisms to operate when ice laden.
Type 4X Type 4
Enclosures used both indoors and out to protect against
corrosion, wind-blown dust and rain, splashing or
hose-directed water, and damage caused by exterior ice
formation.
For indoor and outdoor use to protect against wind-
blown dust and rain, splashing or hose-directed water,
and damage caused by exterior ice formation.
Type 4X
For protection indoors and out from corrosion, wind-
blown dust and rain, splashing or hose-directed water,
and damage caused by exterior ice formation.
Compliances, specifications and availability are subject to change without notice.
NEMA & IP enclosures
Enclosure type cross reference: NEMA/UL/CSA
www.eaton.com
www.eaton.com/arrowhart Q-31
EATON 2016 Arrow Hart Buyers Guide
SECTION
Q
(con’t)
UNDERWRITERS LABORATORIES UL50
CANADIAN STANDARDS ASSOC. CAN/CSA C22.2 No. 94-M91
Type 5 Special purposes enclosures
Used primarily indoors for protection against airborne
dust or dirt, and non-corrosive liquids. Intended use and description
Enclosures are constructed to protect against specific environmental conditions, as well as accidental contact with the
equipment enclosed within.
Type 6
For protection indoors and out against hose-directed
water, water entry during occasional short-term
submersion at low-pressure depths, and damage caused
by exterior ice formation.
Type 1 Type 5
(There is no CSA equivalent.) Enclosures exclusively for indoor use, providing
protection against dripping and light splashing of
non-corrosive liquids, as well as airborne dust, lint,
fibers, and filings.
Type 6P Type 2 Type 6
For protection indoors and out against hose-directed
water, water entry during long-term submersion at low-
pressure depths, and damage caused by exterior
ice formation.
Enclosures are designed to provide protection, primarily
indoors, against dripping and small amounts of splashing
of non-corrosive liquids, and dirt.
Enclosures used both indoors and out for protection
against water entry during occasional short-term
submersion at low-pressure depths, remaining
undamaged by exterior ice formation.
Type 12 Type 3 Type 6P
Used primarily indoors to protect against airborne dust
and dirt, and non-corrosive liquids.
Enclosures, designed for both indoor and outdoor use,
protect against rain and snow, and remain undamaged
by the external formation of ice.
Enclosures for use both indoors and out for protection
against water entry during long-term submersion at
low-pressure depths. In addition, it provides corrosion
resistance over extended periods of time and remains
undamaged by exterior ice formation.
Type 12K Type 3R Type 12
Used primarily indoors to protect against dust and dirt,
and non-corrosive liquids.
Enclosures used both indoors and out for protection
against rain and snow, remaining undamaged by exterior
ice formation.
Enclosures exclusively for indoor use, providing
protection against airborne dust, lint, fibers, and filings,
as well as dripping and light splashing of non-corrosive
liquids. These enclosures are not provided with
knockouts.
Type 13 Type 3S Type 12K
Used primarily indoors to protect against dust, as well
as accidental spraying by water, oil, or non-corrosive
coolants.
Enclosures used both indoors and out for protection
against rain, snow, and airborne dust, and enable
external mechanisms to operate efficiently even when
ice laden.
Enclosures provided with knockouts and used exclusively
indoors for protection against airborne dust, lint, fibers,
and filings, as well as dripping and light splashing of
non-corrosive liquids.
Type 4 Type 13
Enclosures used both indoors and out for protection
against rain, snow, airborne dust, and both splashing and
hose-directed water, remaining undamaged by exterior
ice.
Enclosures exclusively for indoor use, providing
protection against airborne dust, lint, fibers, and filings,
as well as from seepage and spraying of non-corrosive
liquids, including oils and coolants.
Type 4X
Enclosures used both indoors and out for protection
against rain, snow, airborne dust, and both splashing
and hose-directed water, remaining undamaged by
exterior ice formation.
Compliances, specifications and availability are subject to change without notice.
NEMA & IP enclosures
Enclosure type cross reference: NEMA/UL/CSA
Q-32
www.eaton.com
www.eaton.com/arrowhart
EATON 2016 Arrow Hart Buyers Guide
Q
SECTION
NAFTA compliant
Buy American Provision, American Recovery and Reinvestment Act
(ARRA) (Section 1605)
ARRA Section 1605 establishes requirements for federal government projects funded with stimulus
monies: “None of the funds appropriated or otherwise made available by [the ARRA] may be used for a
project for the construction, alteration, maintenance, or repair of a public building or public work unless all
of the iron, steel, and manufactured goods used in the project are produced in the United States.” Iron and
steel used as components or subcomponents of other manufactured construction materials do not need to
be produced in the United States. There is no requirement that components and subcomponents be U.S.-
origin provided the manufactured construction material is “produced in the United States.” (FAR 25.001(c)
(4)) Section 1605 does not contain a domestic cost requirement. However, the government has not defined
“produced” for purposes of the ARRA Buy American provision. Many commentators have adopted the
“substantial transformation” test to determine whether a manufactured article is “produced” in the
United States for purposes of Section 1605. Section 1605 contains a requirement that the Buy American
provision be applied in a manner consistent with U.S. obligations under international agreements. As
a result, national treatment is extended to products from countries with which the United States has
entered a free trade agreement (e.g., Canada, Mexico, Bahrain, Chile, etc.) and to products from countries
that have signed the WTO Government Procurement Agreement. National treatment is also extended to
least developed countries (LDCs) (e.g., Bhutan, Mali, Zambia, etc.) but not to Caribbean basin countries
(e.g., Belize, Haiti, Bahamas, etc.). Products that are identified as NAFTA compliant may qualify under
the Buy American Act or ARRA program guidelines. Consult specific project guidelines and compliance
requirements to assure suitability for your project needs.
NAFTA compliant products
meet specifications at time
of print. Product listing
subject to change.
For specific product details
visit www.arrowhart.com or
email cwdmarketing@eaton.com.
Buy American Act (US Code, Title 41, Section 10 (a-d))
The Buy American Act (often BAA, not to be confused with the Buy America (no “n”) Act) applies to all
U.S. federal government agency purchases of goods over certain contract thresholds. The BAA restricts
purchases of supplies and construction materials to domestic products, unless an exception or waiver
applies. Unmanufactured products must be mined or produced in the United States. There is a two-part
test for manufactured articles: (1) article must be manufactured in the United States, and (2) cost of U.S.
components must exceed 50% of the cost of all components in the item. Note: this calculation does not
include labor and overhead for final assembly in the United States. The component cost test is waived
for commercial-off-the-shelf (COTS) items. (FAR 25.001(c)(1). BAA waivers may be available, often at the
discretion of the contracting officer.
Restriction of the use of certain hazardous substances (RoHS)
Parts are manufactured and designed in accordance with article 4 of the European Union’s RoHS2 directive
2011/65/EU

Navigation menu