18 PLUG-IN
RELAYS
Plug-In Relays
Contents
Plug-in Relays
3TX71 Plug-in Relays 18-2
Multifunction Timer Modes 18-7
Socket Accessories 18-7
18
Siemens Canada Limited ICP 2014
18-2
18
PLUG-IN
RELAYS
Plug-In Relays
3TX71 Plug-in Relays
Selection
Siemens offers a wide range of plug-in relays to meet your
industrial needs. Basic style relays are the most economical and
are equipped with a mechanical flag indicator only . Premium
style relays are full featured with LED and mechanical flag
indication, push to test button and typically a latching hold down
door which provides a method of activating the contacts without
applying power to the coil. This feature is very handy during
comissioning and troubleshooting. Premium Bifurcated style
relays are ideal for low minimum holding current requirements
on the contacts. Typical minimum holding current for bifurcated
contacts is 3mA instead of 100mA.
Relays are divided up by the following functions for selection:
b
Base style
b
Contact Arrangement
b
Contact Rating
b
Coil Voltage
b
Optional Features (Basic, Premium and Premium Bifurcated)
Square Base (Narrow)
Contacts
Contact
Rating (A)
Coil
Voltage Basic Relay Premium Relay
Premium
Bifurcated
Uses Socket
3TX7144-
Uses Clip
3TX7144-
Socket
Access
Set
Panel
Mount
Adaptor
3TX7144-
DIN Rail
Mount
Adaptor
3TX7144-
SPDT 20
12 VDC
24 VDC
24 VAC
120 VAC
3TX7109-5BB03C
3TX7109-5BC03C
3TX7109-5BC13C
3TX7109-5BF13C
3TX7109-5JB03
3TX7109-5JC03
3TX7109-5JC13
3TX7109-5JF13
3TX7144-4E6
3TX7144-4E6
3TX7144-4E6
3TX7144-4E6
1L6
1L6
1L6
1L6
B
B
B
B
3L7
3L7
3L7
3L7
3L6
3L6
3L6
3L6
SPDT
20A for
Basic and
Premium
and 3A for
Bifurcated
24 VDC
24 VAC
120 VAC
3TX7110-5BC03C
3TX7110-5BC13C
3TX7110-5BF13C
3TX7110-5JC03
3TX7110-5JC13
3TX7110-5JF13
3TX7110-5JC03B
3TX7110-5JC13B
3TX7110-5JF13B
3TX7144-4E7
3TX7144-4E7
3TX7144-4E7
1L7
1L7
1L7
B
B
B
3L5
3L5
3L5
3L4
3L4
3L4
DPDT
10A for
Basic and
Premium
and 3A for
Bifurcated
24 VDC
24 VAC
120 VAC
3TX7111-3DC03C
3TX7111-3DC13C
3TX7111-3DF13C
3TX7111-3LC03
3TX7111-3LC13
3TX7111-3LF13
3TX7144-4E5
3TX7144-4E5
3TX7144-4E5
1L6
1L6
1L6
B
B
B
3L7
3L7
3L7
3L6
3L6
3L6
DPDT 20
12 VDC
24 VDC
24 VAC
110 VDC
120 VAC
240 VAC
3TX7114-5DB03C
3TX7114-5DC03C
3TX7114-5DC13C
3TX7114-5DF13C
3TX7114-5DH13C
3TX7114-5LB03
3TX7114-5LC03
3TX7114-5LC13
3TX7114-5LF03
3TX7114-5LF13
3TX7114-5LH13
3TX7144-4E6
3TX7144-4E6
3TX7144-4E6
3TX7144-4E6
3TX7144-4E6
3TX7144-4E6
1L6
1L6
1L6
1L6
1L6
1L6
B
B
B
B
B
B
3L7
3L7
3L7
3L7
3L7
3L7
3L6
3L6
3L6
3L6
3L6
3L6
3PDT 15 24 VDC
120 VAC
3TX7116-5FC03C
3TX7116-5FF13C
3TX7116-5NC03
3TX7116-5NF13
3TX7144-4E8
3TX7144-4E8
1L9
1L9
A
A
1M3
1M3
1M4
1M4
4PDT
10A for
Basic and
Premium
and 3A for
Bifurcated
24 VDC
24 VAC
120 VAC
3TX7111-3HC03C
3TX7111-3HC13C
3TX7111-3HF13C
3TX7111-3PC03
3TX7111-3PC13
3TX7111-3PF13
3TX7111-5PC03B
3TX7111-5PC13B
3TX7111-5PF13B
3TX7144-4E5
3TX7144-4E5
3TX7144-4E5
1L6
1L6
1L6
B
B
B
3L7
3L7
3L7
3L6
3L6
3L6
4PDT 15
24 VDC
24 VAC
120 VAC
3TX7117-5HC03C
3TX7117-5HC13C
3TX7117-5HF13C
3TX7117-5PC03
3TX7117-5PC13
3TX7117-5PF13
3TX7144-4E9
3TX7144-4E9
3TX7144-4E9
1L10
1L10
1L10
A
A
A
1M5
1M5
1M5
1M6
1M6
1M6
Option Basic Premium Premium Bifurcated
Mechanical Flag 4 4 4
Push To Test 4 4
Lock Down Door 4 4
LED 4 4
Note: See page 18-7 for socket accessories.
Siemens Canada Limited ICP 2014 18-3
18 PLUG-IN
RELAYS
Plug-In Relays
3TX71 Plug-in Relays
Selection
Option Basic Premium Premium Bifurcated
Mechanical Flag 4 4 4
Push To Test 4 4
Lock Down Door 4 4
LED 4 4
Note: See page 18-7 for socket accessories.
Square Base (Standard)
Contacts
Contact
Rating (A)
Coil
Voltage Basic Relay Premium Relay
Premium
Bifurcated
Uses Socket
3TX7144-
Uses Clip
3TX7144-
Socket
Access
Set
Panel
Mount
Adaptor
3TX7144-
DIN Rail
Mount
Adaptor
3TX7144-
DPDT 16
12 VDC
24 VDC
24 VAC
120 VAC
3TX7115-5DB03C
3TX7115-5DC03C
3TX7115-5DC13C
3TX7115-5DF13C
3TX7115-5LC03
3TX7115-5LC13
3TX7115-5LF13
3TX7144-4E4
3TX7144-4E4
3TX7144-4E4
3TX7144-4E4
1L12
1L12
1L12
1L12
A
A
A
A
3PDT 16
12 VDC
24 VDC
24 VAC
120 VAC
240 VAC
3TX7115-5FB03C
3TX7115-5FC03C
3TX7115-5FC13C
3TX7115-5FF13C
3TX7115-5FH13C
3TX7115-5NB03
3TX7115-5NC03
3TX7115-5NC13
3TX7115-5NF13
3TX7115-5NH13
3TX7144-4E4
3TX7144-4E4
3TX7144-4E4
3TX7144-4E4
3TX7144-4E4
1L12
1L12
1L12
1L12
1L12
A
A
A
A
A
DPDT
Note: No
Lock Down
Door on
Premium
Style
20
12 VDC
24 VDC
24 VAC
120 VAC
240 VAC
3TX7119-5LB03
3TX7119-5LC03
3TX7119-5LC13
3TX7119-5LF13
3TX7119-5LH13
3TX7144-4E4
3TX7144-4E4
3TX7144-4E4
3TX7144-4E4
3TX7144-4E4
1L12
1L12
1L12
1L12
1L12
A
A
A
A
A
Specialty Relay
Contacts
Contact
Rating
(A)
Coil
Voltage Basic Relay Premium Relay
Premium
Bifurcated
Uses Socket
3TX7144-
Uses Clip
3TX7144-
Socket
Access
Set
Panel
Mount
Adaptor
3TX7144-
DIN Rail
Mount
Adaptor
3TX7144-
DPDT
Latching 16
24 VDC
24 VAC
120 VAC
3TX7137-5DC03
3TX7137-5DC13
3TX7137-5DF13
3TX7144-1E4
3TX7144-1E4
3TX7144-1E4
1L12
1L12
1L12
Siemens Canada Limited ICP 2014
18-4
18
PLUG-IN
RELAYS
Plug-In Relays
3TX71 Plug-in Relays
Selection
Octal Base (Standard)
Contacts
Contact
Rating (A)
Coil
Voltage Basic Relay Premium Relay
Premium
Bifurcated
Uses Socket
3TX7144-
Uses Clip
3TX7144-
Socket
Access
Set
Panel
Mount
Adaptor
3TX7144-
DIN Rail
Mount
Adaptor
3TX7144-
DPDT 16
12 VDC
24 VDC
24 VAC
110 VDC
120 VAC
3TX7112-1DB03C
3TX7112-1DC03C
3TX7112-1DC13C
3TX7112-1DF03C
3TX7112-1DF13C
3TX7112-1LB03
3TX7112-1LC03
3TX7112-1LC13
3TX7112-1LF03
3TX7112-1LF13
3TX7144-4E2
3TX7144-4E2
3TX7144-4E2
3TX7144-4E2
3TX7144-4E2
1L14
1L14
1L14
1L14
1L14
A
A
A
A
A
3PDT 16
12 VDC
24 VDC
24 VAC
110 VDC
120 VAC
220/230 VAC
3TX7112-1FB03C
3TX7112-1FC03C
3TX7112-1FC13C
3TX7112-1FF13C
3TX7112-1NC03
3TX7112-1NC13
3TX7112-1NF03
3TX7112-1NF13
3TX7112-1NG13
3TX7144-4E3
3TX7144-4E3
3TX7144-4E3
3TX7144-4E3
3TX7144-4E3
3TX7144-4E3
1L14
1L14
1L14
1L14
1L14
1L14
A
A
A
A
A
A
Hermetically Sealed (Class 1 Div 2)
Contacts
Contact
Rating (A)
Coil
Voltage Basic Relay Premium Relay
Premium
Bifurcated
Uses Socket
3TX7144-
Uses Clip
3TX7144-
Socket
Access
Set
Panel
Mount
Adaptor
3TX7144-
DIN Rail
Mount
Adaptor
3TX7144-
DPDT
(Octal) 12
12 VDC
24 VDC
110 VDC
120 VAC
3TX7127-5HB00
3TX7127-5HC00
3TX7127-5HF00
3TX7127-5HF10
3TX7144-4E2
3TX7144-4E2
3TX7144-4E2
3TX7144-4E2
1L12
1L12
1L12
1L12
A
A
A
A
4PDT
(Square) 3
12 VDC
24 VDC
24 VAC
120 VAC
3TX7127-3HB00
3TX7127-3HC00
3TX7127-3HC10
3TX7127-3HF10
3TX7144-4E5
3TX7144-4E5
3TX7144-4E5
3TX7144-4E5
1L11
1L11
1L11
1L11
B
B
B
B
4PDT
(Square) 5
12 VDC
24 VDC
120 VAC
3TX7127-3HB03
3TX7127-3HC03
3TX7127-3HF13
3TX7144-4E5
3TX7144-4E5
3TX7144-4E5
1L11
1L11
1L11
B
B
B
Option Basic Premium Premium Bifurcated
Mechanical Flag 4 4 4
Push To Test 4 4
Lock Down Door 4 4
LED 4 4
Note: See page 18-7 for socket accessories.
Siemens Canada Limited ICP 2014 18-5
18 PLUG-IN
RELAYS
Note: See page 18-7 for socket accessories.
Plug-In Relays
3TX71 Plug-in Relays
Selection
Enclosed Power Relays
Contacts
Contact
Rating (A)
Coil
Voltage Basic Relay
Premium
Relay
Premium
Bifurcated
Uses Socket
3TX7144-
Uses Clip
3TX7144-
Socket
Access
Set
Panel Mount
Adaptor
3TX7144-
DIN Rail
Mount
Adaptor
3TX7144-
DPST-NO 30
24 VAC
120 VAC
230 VAC
3TX7131-4CC13
3TX7131-4CF13
3TX7131-4CH13
DPDT 30 NO/
3 NC
12 VDC
24 VDC
24 VAC
120 VAC
230 VAC
3TX7131-4DB03
3TX7131-4DC03
3TX7131-4DC13
3TX7131-4DF13
3TX7131-4DH13
SPDT 30 NO/
15 NC
5 VDC
12 VDC
24 VDC
120 VAC
3TX7132-6BA03
3TX7132-6BB03
3TX7132-6BC03
3TX7132-6BF13
Open Power Relays
Contacts
Contact
Rating (A)
Coil
Voltage Basic Relay
Metal Cover
7144-
Premium
Bifurcated
Uses Socket
3TX7144-
Uses Clip
3TX7144-
Socket
Access
Set
Panel Mount
Adaptor
3TX7144-
DIN Rail
Mount
Adaptor
3TX7144-
SPST NO-DM
SPST NO-DM
SPST NO-DM
SPST NC-DM
40
24 VAC
120 VAC
240 VAC
240 VDC
3TX7130-0AC13
3TX7130-0AF13
3TX7130-0AH13
3TX7130-0AC03
1M0
1M0
1M0
1M0
SPST NC-DB
SPDT
SPDT
SPDT
SPDT
40
120 VAC
24 VAC
120 VAC
240 VAC
277 VAC
3TX7130-0QF13
3TX7130-0BC13
3TX7130-0BF13
3TX7130-0BH13
3TX7130-0BS13
1M0
1M0
1M0
1M0
1M0
DPDT 40
24 VAC
120 VAC
240 VAC
277 VAC
12 VDC
24 VDC
48 VDC
110 VDC
3TX7130-0DC13
3TX7130-0DF13
3TX7130-0DH13
3TX7130-0DS13
3TX7130-0DB03
3TX7130-0DC03
3TX7130-0DD03
3TX7130-0DF03
1M0
1M0
1M0
1M0
1M0
1M0
1M0
1M0
DPST NO 40
24 VAC
120 VAC
240 VAC
277 VAC
12 VDC
24 VDC
48 VDC
110 VDC
3TX7130-0CC13
3TX7130-0CF13
3TX7130-0CH13
3TX7130-0CS13
3TX7130-0CB03
3TX7130-0CC03
3TX7130-0CD03
3TX7130-0CF03
1M0
1M0
1M0
1M0
1M0
1M0
1M0
1M0
DPDT
(Mag Blowout) 40
120 VAC
12 VDC
24 VDC
48 VDC
110 VDC
3TX7130-0RF13
3TX7130-0RB03
3TX7130-0RC03
3TX7130-0RD03
3TX7130-0RF03
1M0
1M0
1M0
1M0
1M0
Siemens Canada Limited ICP 2014
18-6
18
PLUG-IN
RELAYS
Plug-In Relays
3TX71 Plug-in Relays
Selection
Octal Based Timers
Contacts
Contact
Rating (A)
Coil
Voltage Basic Relay Time Range Function
Uses Socket
3TX7144-
Uses Clip
3TX7144-
Socket
Access
Set
Panel Mount
Adaptor
3TX7144-
DIN Rail
Mount
Adaptor
3TX7144-
DPDT 12
24 V AC/DC
120 V AC/DC
240 VAC
OND-DFOB-24
OND-DFOB-120
OND-DFOB-240
0.1S - 10h
0.1S - 10h
0.1S - 10h
A, C
A, C
A, C
3TX7144-4E2
3TX7144-4E2
3TX7144-4E2
1L8
1L8
1L8
A
A
A
DPDT 12
24 V AC/DC
120 V AC/DC
240 VAC
OFD-DFOB-24
OFD-DFOB-120
OFD-DFOB-240
0.1S - 10h
0.1S - 10h
0.1S - 10h
D, E
D, E
D, E
3TX7144-4E3
3TX7144-4E3
3TX7144-4E3
1L8
1L8
1L8
A
A
A
Square Based Timers
Contacts
Contact
Rating (A)
Coil
Voltage Basic Relay Time Range Function
Uses Socket
3TX7144-
Uses Clip
3TX7144-
Socket
Access
Set
Panel Mount
Adaptor
3TX7144-
DIN Rail
Mount
Adaptor
3TX7144-
DPDT 12
24 V AC/DC
120 V AC/DC
240 VAC
OND-DFSB-24
OND-DFSB-120
OND-DFSB-240
0.1S - 10h
0.1S - 10h
0.1S - 10h
A, C
A, C
A, C
3TX7144-1E4
3TX7144-1E4
3TX7144-1E4
1L8
1L8
1L8
DPDT 12
24 V AC/DC
120 V AC/DC
240 VAC
OFD-DFSB-24
OFD-DFSB-120
OFD-DFSB-240
0.1S - 10h
0.1S - 10h
0.1S - 10h
D, E
D, E
D, E
3TX7144-1E4
3TX7144-1E4
3TX7144-1E4
1L8
1L8
1L8
Front Panel Timers
Contacts
Contact
Rating
(A)
Coil
Voltage Basic Relay Time Range Function
Uses Socket
3TX7144-
Uses Clip
3TX7144-
Socket
Access
Set
Panel
Mount
Adaptor
3TX7144-
DIN Rail
Mount
Adaptor
3TX7144-
DPDT
SPDT
DPDT
12
12-240 V AC/DC
12-240 V AC/DC
12-240 V AC/DC
OFD-DFPR-00
OND-DFPR-01
OND-DFPR-02
0.1S - 9990h
0.1S - 9990h
0.1S - 9990h
A,B,C,D,E,F,G,H,I,J
A,B,C,D,E,F,G,H,I,J
A,B,C
3TX7144-4E3
3TX7144-4E2
3TX7144-4E2
1L25
1L25
1L25
Selecting Time Range
Time Range SW II SW III SW IV
0.1s - 1s OFF OFF OFF
1s - 10s OFF OFF ON
10s - 100s OFF ON OFF
0.1m - 1m OFF ON ON
1m - 10m ON OFF OFF
10m - 100m ON OFF ON
0.1h - 1h ON ON OFF
1h - 10h ON ON ON
Selecting Function
Function for OND SW I
On Delay OFF
Interval ON
Function for OFD SW I
Off Delay OFF
One Shot ON
Note: See page 18-7 for socket accessories.
Siemens Canada Limited ICP 2014 18-7
18 PLUG-IN
RELAYS
Multifunction Timer Modes
Function Name Description
AOn Delay
(Power On)
When input voltage U is applied, timing delay t begins. Relay contacts R change state after the time delay is complete. Contacts R
return to their shelf state when input voltage U is removed. Trigger switch is not used in this function.
BRepeat Cycle
(Starting Off)
When input voltage U is applied, time delay t begins. When time delay t is complete, relay contacts R change state for time delay t.
This cycle will repeat until input voltage U is removed. Trigger switch is not used in this function.
CInterval
(Power On)
When input voltage U is applied, relay contacts R change state immediately and timing cycle begins. When time delay is complete,
contacts return to shelf state. When input voltage U is removed, contacts will also return to their shelf state. Trigger switch is not
used in this function.
DOff Delay
(S Break)
Input voltage U must be applied continuously. When trigger switch S is closed, relay contacts R change state. When trigger switch
S is opened, delay t begins. When delay t is complete, contacts R return to their shelf state. If trigger switch S is closed before time
delay t is complete, then time is reset. When trigger switch S is opened, the delay begins again, and relay contacts R remain in their
energized state. If input voltage U is removed, relay contacts R return to their shelf state.
ERetrigerable
One Shot
Upon application of input voltage U, the relay is ready to accept trigger signal S. Upon application of the trigger signal S, the relay
contacts R transfer and the preset time t begins. At the end of the preset time t, the relay contacts R return to their normal condition
unless the trigger switch S is opened and closed prior to time out t (before preset time elapses). Continuous cycling of the trigger
switch S at a rate faster than the preset time will cause the relay contacts R to remain closed. If input voltage U is removed, relay
contacts R return to their shelf state.
FRepeat Cycle
(Starting On)
When input voltage U is applied, relay contacts R change state immediately and time delay t begins. When time delay t is complete,
contacts return to their shelf state for time delay t. This cycle will repeat until input voltage U is removed. Trigger switch is not used
in this function.
GPulse
Generator
Upon application of input voltage U, a single output pulse of 0.5 seconds is delivered to relay after time delay t. Power must be
removed and reapplied to repeat pulse. Trigger switch is not used in this function.
HOne Shot
Upon application of input voltage U, the relay is ready to accept trigger signal S. Upon application of the trigger signal S, the relay
contacts R transfer and the preset time t begins. During time-out, the trigger signal S is ignored. The relay resets by applying the
trigger switch S when the relay is not energized.
IOn/Off Delay
(S Make/Break)
Input voltage U must be applied continuously. When trigger switch S is closed, time delay t begins. When time delay t is complete,
relay contacts R change state and remain transferred until trigger switch S is opened. If input voltage U is removed, relay contacts R
return to their shelf state.
JMemory Latch
(S Make)
Input voltage U must be applied continuously. Output changes state with every trigger switch S closure. If input voltage U is
removed, relay contacts R return to their shelf state.
Socket Accessories
Accessory
Series
MOV
24VAC/DC
MOV
120VAC/DC
R/C
6-24VAC/DC
R/C
110-240VAC/DC
Diode
6-250VDC
A3TX7144-H1 3TX7144-H2 3TX7144-H4 3TX7144-H5 3TX7144-H6
B3TX7144-H9 3TX7144-H17 — — 3TX7144-H12
Plug-In Relays
3TX71 Plug-in Relays
Accessories
Siemens Canada Limited ICP 2014
18-8
18
PLUG-IN
RELAYS
Notes

Navigation menu