1000513386 Catalog

2016-09-04

: Pdf 1000513386-Catalog 1000513386-Catalog B4 unilog

Open the PDF directly: View PDF PDF.
Page Count: 162 [warning: Documents this large are best viewed by clicking the View PDF Link!]

Catalogue
PowerLogic
Energy management, revenue metering and power quality monitoring
Electrical network management
2plsed309005eN
General contents
PowerLogic™ applications
Market segments
Panorama of the PowerLogic range
Index of catalogue numbers
Power management software introduction
4
5
7
13
149
Current transformers 16
Panel instruments 25
iAMP iVLT iFRE AMP/VLT iCH/iCI
Basic energy meters 35
iEM2000 iEM3000
Multi-circuit and wireless metering 43
BCPM EM4300 EM4800
Basic multi-function metering 61
PM3000 PM5350 PM5000
Intermediate metering 85
PM800 PM8000
Advanced metering 100
ION7550/ION7650 CM4000T
Advanced utility metering 114
ION8650 ION8800
Communications 129
Energy Server Com'X
200/210/510 EGX100/300 ION7550 RTU
Power management software 149
3
PLSED309005EN
PowerLogic technology forms one part of your total energy
management solution from Schneider Electric. As the global
energy management specialist, we offer end-to-end power,
building and process management solutions that help you
optimise energy use and costs, improve performance,
enhance comfort and safety, and deliver uninterrupted service
while taking responsible care of our planet.
Our expert services can help you audit your energy use and
build your energy action plan. From power factor correction
systems, harmonic ltering and variable speed drives to HVAC
and lighting controls, we offer a complete range of energy
efcient technologies.
Schneider Electric believes every business can increase
productivity while consuming less and achieving energy
savings of 10% to 30%.
Saving energy reduces costs and pollution, but you need the
tools to uncover all opportunities, avoid risks, track progress
against goals, and verify success. Schneider Electric
provides these tools via the world’s most advanced energy
intelligence technology: PowerLogic.
The PowerLogic range of meters and software help manage
all energy assets, every second of the day. A PowerLogic
system enables all stakeholders, from CEO to facility and
engineering managers, to respond quickly to potential
problems and manage energy in nancial and environmental
terms.
PowerLogic technology delivers the key performance
indicators and analytics that you need to strategically balance
emissions, efciency, reliability and cost.
What is PowerLogic?
4PLSED309005EN
Cutting-edge technology to increase protability
PowerLogic technology converts the complex dynamics governing the relationship between power generation and distribution on the utility
side, and energy consumption, cost and reliability on the consumer side, into timely, easily understood information. Businesses can use this
powerful to improve tactical actions and strategic decision making.
From a single facility to an entire enterprise, PowerLogic meters monitor key distribution points 24 hours a day. Whether from generators,
substations, service entrances, mains, feeders, loads or 3rd party equipment and systems, PowerLogic technology tracks, records and reports
all real-time conditions and historical performance data. Intuative web-based interfaces give stakeholders access to this data as well as
advanced analytics, alarm annunciation and control capabilities. It supports comprehensive energy management programs by tracking
performance and empowering you to make effective decisions.
Power availability
and reliability
bValidate that power quality
complies with the energy contract
bVerify the reliable operation of
power and mitigation equipment
bImprove response to power-
related problems
bLeverage existing infrastructure
capacity and avoid over-building
bSupport proactive maintenance
to prolong asset life
Energy efciency
and cost savings
bMeasure efciency, reveal
opportunities and verify
savings
bManage green house gas
emissions
bAllocate energy costs to
departments or processes
bReduce peak demand and
power factor penalties
bEnable participation in load
curtailment programs
(e.g. demand response)
bStrengthen rate negotiation
with energy suppliers
bIdentify billing discrepancies
bSub-bill tenants for energy
costs
Energy availability
and reliability
bImprove T&D network
reliability
bEnhance substation
automation
bMaximise the use of your
existing infrastructure
Revenue metering
and power quality
bMaximise metering accuracy
at all interchange points
bVerify compliance with new
power quality standards
bAnalyse and isolate the source
of power quality problems
Applications for Supply and Demand
Applications
Your power monitoring system needs to be an integral part
of your overall business strategy. PowerLogic ts in with
your objectives and expands your network's capabilities
with wide ranging, exible deployment options to meet
your needs.
5
PLSED309005EN
Industry
From nance to engineering, PowerLogic technology gives industry professionals
the energy intelligence and control they need to support strategic decisions and
establish best energy practices. It will help you reduce operational costs and meet
new emissions standards without compromising production schedules or product
quality. Key points are monitored throughout your power distribution, building and
backup systems. Enterprise-level software helps you maximise the use of your
existing energy assets, increase energy efciency and avoid demand or power
factor penalties. Use it to uncover hidden power problems that can shorten
equipment life or cause costly downtime.
Market segments
Buildings
Today, facility managers are pushed to the limit with demands on time, staff
reductions, increasing responsibilities, complexity of systems, and capex and opex
pressures. At the same time, critical business operations depends on your ability to
maintain reliable operations, reduce energy costs, and get the most out of your
electrical assets. PowerLogic offers cutting-edge exibility let you extend your power
management system at your own pace and within your own budget. It allows for
integration with third-party devices and systems. Save thousands of engineering
hours with ready-to-use device drivers and precongured reporting procedures.
cost allocation
procurement optimisation
power factor correction
measurement and
verication
infrastructure optimisation
power quality analysis
tenant sub-billing
cost allocation
energy efciency /
benchmarking
procurement optimisation
power availability
demand response / load
curtailment 30%
Monitoring and control
systems can save you up
to 30% on your annual
energy bill
6PLSED309005EN
Critical infrastructure
PowerLogic technology helps keep your systems operating continuously and
securely with an economical supply of energy. Whether you manage data,
communication, transportation or environmental services, minimising the risk of
power-related downtime and keeping costs under control is a priority. A
PowerLogic solution monitors all power and cooling systems and accurately tracks
their energy consumption. Enterprise-level software delivers insightful diagnostics
and metrics to help verify the reliability of your backup systems and maximise the
use of existing capacity to defer new capital investments. You can also reveal
energy inefciencies and strengthen energy procurement across multiple sites.
Utilities
Today’s energy market is more complex than ever before. Whether you generate,
transmit or distribute electricity, more stakeholders need shared access to timely,
accurate energy data from more exchange points and you need to maintain power
availability and reduce price volatility in the face of rising demand and transmission
congestion. A PowerLogic energy information system helps you meet all of these
challenges by:
bMetering all key interchange points with the highest possible accuracy
bImproving the quality of power delivered to your customers
bEssuring the reliability and efciency of your network and equipment.
From advanced energy and power quality metering systems to enterprise-level
analytic software, PowerLogic solutions deliver business-critical information that
conventional metering, SCADA and billing systems cannot. It gives you the energy
intelligence and control needed to track performance, stay informed of critical
conditions and empower you to make strategic decisions. It will help you increase
reliability, maximise the use of resources and improve service.
infrastructure optimisation
power quality analysis compliance
alarming and event notication
energy efciency
cost allocation
procurement
optimisation
revenue metering
power availability and reliability
Market segments (cont.)
7
PLSED309005EN
Panorama of the PowerLogic
range
Product selection guide
Current transformers Basic panel meters
CT Name iAMP / iVLT AMP / VLT iFRE iCH / iCI
current transformer Function ammeter, voltmeter frequency meter hour counter
pulse counter
Installation
b�insulated cable,
diameter 21 to 35 mm,
through transformer
b�busbar through transformer
b�cable connections
Applications
Panel instrumentation
Panel instrumentation I / U I / U Fhours /pulses
Energy efciency and cost
Sub billing and cost allocation
Demand and load management
Billing analysis
Power availability
and reliability
Compliance monitoring
Sag/swell, transient
Harmonics
Revenue metering
Revenue meter
Characteristics Characteristics
b�transformation ratio:
40/5 A to 6000/5 A
b�accuracy: class 0.5 to 3
b�maximum rated
operational voltage: 720 V AC
b�tropicalised
Measurement accuracy class 1.5 ± 0.5 % ± 1
digit
class 1.5 ± 0.5 % ± 1 digit
Installation
DIN rail
4 x 18 mm
modules
DIN rail
2 x 18 mm
modules
ush mounted
72 x 72 mm
96 x 96 mm
DIN rail
2 x 18 mm
modules
iCI, iCH: DIN rail
2 x 18 mm
modules
CH: ush mount
Voltage measurement iVLT,:
500 V AC direct
or external VT
iVLT:
600 V AC direct
or external VT
VLT:
500 V AC direct
or external VT
400 V AC direct
Current measurement iAMP:
30 A direct
or external CT
iAMP:
10 A direct
or external CT
AMP:
external CT
Communication ports
Inputs / Outputs
Memory capacity
page 16 page 25 page 25 page 27 page 25 page 31
8PLSED309005EN
Panorama of the PowerLogic
range (cont.)
Product selection guide
Basic energy meters Multi-circuit metering
Name iEM2000 /
iEM2010 / iEM2000T /
iEM2100
iEM3000 Series BCPM EM4800
Function kilowatt-hour meters branch circuit monitor
IEC 61036 Class 1
multi-circuit energy meter
Class 0.5 ANSI C12.1, C12.20
Class 0.5S IEC 62053-22
Applications
Panel instrumentation
Panel instrumentation EI, U, F, P, Q, S, PF, E
(Power demand and
current demand)
I, U, F, P, Q, S, PF, E
(Power demand and
current demand)
I, U, F, P, Q, S, PF, E
(Power demand and
current demand)
Energy efciency and cost
Sub billing and cost allocation
Demand and load management
Billing analysis
Power availability
and reliability
Compliance monitoring
Sag/swell, transient
Harmonics
Revenue metering
Revenue meter
Characteristics
Measurement accuracy Class 0.5S / Class 1 class 1 (mains active energy) Class 0.5S
Installed in panel or enclosure Installed in panel or
enclosure
Installation
DIN rail
1, 2, 5, or 7 x 18 mm modules
90 277 V Line to Neutral
voltage Inputs
80 - 480 V AC L-L without PTs,
Up to 999 kV with external PTs
CT strips for branch circuits
and external CTs for mains
Split- or solid-core CTs
Voltage measurement 400 V AC direct 50 V to 330 V (Ph-N)
80 V to 570 V (Ph-Ph)
up to 1MV AC (ext VT)
1 for main 2
2
Current measurement 40 to 125 A direct
or external CT
Communication ports
page 35 page 38 page 43 page 58
9
PLSED309005EN
Panorama of the PowerLogic
range (cont.)
Product selection guide
Basic multi-function metering
Name PM3000 Series PM5350 / PM5350IB PM5100 / PM5300 /
PM5500
Function metering & sub-metering
Class 0.5S IEC 62053-22
Class 1 IEC 62053-21
Class 2IEC 62053-23
Class 0.5S IEC 62053-22
Class IEC 61000-4-2
Class IEC 61000-3-3
metering & sub-metering
Class 0.5S
IEC 62053-22
Class 0.2S (PM55xx)
IEC 62053-22
Class 1/2 IEC 62053-24
Applications
Panel instrumentation
Panel instrumentation I, U, F, P, Q, S, PF, E
(Power demand and
current demand)
I, U, F, P, Q, S, PF, E
(Power demand and
current demand)
I, U, F, P, Q, S, PF, E
(Power demand and
current demand)
Energy efciency and cost
Sub billing and cost allocation
Demand and load management
Billing analysis
Power availability & reliability
Harmonics
Dip/swell, transient
Compliance monitoring
Revenue metering
Revenue metering
Characteristics
Measurement accuracy
(active energy)
Class 0.5 Class 0.5 Class 0.2S (PM55xx)
Class 0.5S
Installation
DIN rail Flush mount
96 mm x 96 mm
Flush mount
96 mm x 96 mm
Voltage measurement
50V to 330V AC (Ph-N)
80V to 570V AC (Ph-Ph)
up to 1MV AC (ext VT)
20-480 V AC (L-L)
20-277 V AC (L-N)
20 V L-N / 35 V L-L to 277 V L-N
/480 V L-L
/600 V L-L (PM55xx)
Current measurement external CT external CT external CT
Communication ports 1 1 2
Inputs / Outputs
2 I/O
4 I/O
6 I/O (PM55xx)
Memory capacity 256 kb
1.1 MB (PM55xx)
page 68 page 73 page 85
10 PLSED309005EN
Intermediate metering
Name PM810 PM820 /
PM850
PM870 PM8000
Function energy and basic PQ power meter
IEC 61557-12
PMD/SD/K70/0.5
PMD/SS/K70/0.5
ANSI 12.20 Class 0.2S real energy
energy and basic PQ meter
IEC 61557-12
IEC 62053-22
IEC 61000-4-30 Class S
IEC 62586 PQI-S
ANSI C12.20 Class 0.2
PMD/Sx/K70/0.2
Applications
Panel instrumentation
Panel instrumentation I
, U, F, P, Q, S, PF, E, THD, Min/Max,
harm, alarm, I/O (I, U unbalance,
demand, clock/cal (PM810 w/PM810LOG)
I, U, F, P, Q, S, PF, E, THD, Min/Max,
harm, alarm, I/O (I, U unbalance,
demand, clock/cal
Energy efciency and cost
Sub billing and cost allocation
Demand and load management
Billing analysis
Power availability & reliability
Harmonics w/PM810LOG
Dip/swell, transient dip/swell
Compliance monitoring PM850 only
Revenue metering
Revenue metering
Characteristics
Measurement accuracy
(active energy)
ANSI 62053-22 Class 0.5S
ANSI 12.20 Class 0.2S
IEC 61053-22 Class 0.2S
ANSI 12.20 Class 0.2S
Installation
Flush & DIN rail mount
96 mm x 96 mm
Flush & DIN rail mount
96 mm x 96 mm
Voltage measurement
0-347 VAC L-N 3P (0-600 VAC L-L) 57-400 VAC L-N 3P
(100-690 VAC L-L)
Current measurement external CT external CT external CT external CT
Communication ports 1 - 4 (option) 1 - 4 (optionw) 1 - 4 (options) 2
Inputs / Outputs 18 I/O 18 I/O 18 I/O up to 27 DI, 9 DO
up to 16 AI, 8 AO
Memory capacity
80 kb with
PM810 LOG
80 / 800
kb
800
kb
512 MB
page 92 page 100
Panorama of the PowerLogic
range (cont.)
Product selection guide
11
PLSED309005EN
Advanced metering Advanced utility metering
Name
ION7550 ION7650
CM4000T ION8650 ION8800
A B C A B C
Function energy & power quality meter
IEC 62052-11
IEC 62053-22/23
Class 0.2S
IEC 61000-4-30 Class A
energy & power quality meter
IEC 62053-22
ANSI 12.20 Class 0.2S real
energy
energy & power quality meter
IEC 62052-11
IEC 62053-22/23
Class 0.2S
IEC 61000-4-30 Class A
energy & power quality meter
IEC 62052-11
IEC 62053-22/23
Class 0.2S
IEC 61000-4-30
Applications
Panel instrumentation
Panel instrumentation I, U, F, P, Q, S, PF, E (demand, minimum and maximum values) I, U, F, P, Q, S, PF, E (demand, minimum and maximum
values)
Energy efciency & cost
Sub billing and cost allocation
Demand and load management
Billing analysis
Power availability & reliability
Harmonics
Dip/swell, transient
Compliance monitoring
Revenue metering
Revenue metering
Characteristics
Measurement accuracy
(active energy)
Class 0.2S Class 0.2S Class 0.2S Class 0.2S
Installation
DIN 192
standard cutout
(186 x 186 mm)
ANSI socket mount 9S, 35S,
36S, 39S and 76S; FT21
switchboard case
DIN 43862 rack
Voltage measurement 57-347V L-N AC or
100-600V L-L AC
0 to 600 V AC
0 to 1200 kV AC (ext. VT)
57-277V L-N AC
(9S, 36S);
120-480 V L-L AC (35S)
57-288V L-N AC or
99-500V L-L AC
Current measurement external CT external CT external CT external CT
Communication ports 5 3 5 5
Inputs / Outputs up to 32 I/O up to 25 I/O up to 22 I/O up to 16 I/O
Memory capacity up to 10 MB up to 32 MB 10 MB 4 MB 2 MB up to 10 MB
page 107 page 114 page 121 page 129
Panorama of the PowerLogic
range (cont.)
Product selection guide
12 PLSED309005EN
Panorama of the PowerLogic
range (cont.)
Product selection guide
Communications Power management software
Name Com'X 200 / 210 /
510
EGX100 / 300 ION7550 RTU StruxureWarePower management
software
Function Ethernet GPRS data
logger
Ethernet Integrate
gateway server
Ethernet
gateway-server +
onboard I/O
Power management
Features
RS485 / Ethernet gateway
Devices supported
EM3000 Series, iEM3000
Series, PM800 Series,
ION7300,
Acti 9 Smartlink Masterpact,
PM5000 Series, Compact
NSX,
iEM1,
iEM2000,
iEM3000,
PM3000 Series
Acti 9 Smartlink,
BCPM Series,
CM Series
PM800 Series, CM4000
Series,
DM6000, DM6300,
iEM3000 Series,
ION8800, ION7550/7650,
PM200, PM300, PM5350,
PM700, PM800, Sepam
Series,
Compact NSX,
Vigilohm IM20/IM20-H
PM5350, PM8000
ION8800, ION7550/7650,
Modbus devices
PM5350
PM5000
PM8000
Web server with
standard HTML pages
(Conguration only) (Conguration only)
Web server with
custom HTML pages
EGX300 only
Real time data EGX300 only
Historical data
Export to Internet database
server
EGX300 only
Automatic notication
Alarm and event logs
Waveform display
Custom animated graphics
Manual/automatic reports
Characteristics
Ethernet ports
Modbus TCP/IP protocol
210/100 Base
TX port
10/100 Base
TX port
StruxureWare™ is a suite of interoperable,
and scalable supervisory software dedicated
to power monitoring that enables you to
maximize operational efciency, optimize
power distribution systems, and improve
bottom-line performance.
RS485 (2-wire / 4-wire) ports
Modbus protocol
1 1 1
Number of devices
connected directly
32 modbus devices
6 pulse meters (or dry
contacts) – 2 analogue
sensors
32 64
RS232 conguration ports 1 1
Miscellaneous Connectivity: WiFi,
GPRS,or Ethernet
Serial line to Ethernet
connectivity
modem port
I/O (24 I/30 O max)
Installation DIN rail DIN rail DIN 192 cutout
(186 x 186 mm)
page 138 page 144 page 148 page 156
13
PLSED309005EN
Index of catalogue numbers
Cat. no. Description Page
15100
15125 iCMV voltmeter selector switch, DIN rail 30
15126 iCMA ammeter selector, DIN rail 30
15200
15201 iVLT digital voltmeter, DIN rail 26
15202 iAMP direct reading digital ammeter, DIN rail 26
15208 iFRE digital frequency meter, DIN rail 26
15209 iAMP multi-rating digital ammeter, DIN rail 26
15400
15440 iCH hour counter, DIN rail (230 V AC) 31
15443 iCI impulse counter, DIN rail 32
15600
15607 CH hour counter, 48 x 48 (24 V AC) 31
15608 CH hour counter, 48 x 48 (230 V AC) 31
15609 CH hour counter, 48 x 48 (12 to 36 V DC) 31
16000
16029
iAMP analogue ammeter for direct connection, DIN
rail
25
16030 iAMP analogue ammeter for connection to TC
(delivered without dial), DIN rail
25
16031 Dial, 0-5 A, for iAMP 16030 25
16032 Dial, 0-50 A, for iAMP 16030 25
16033 Dial, 0-75 A, for iAMP 16030 25
16034 Dial, 0-100 A, for iAMP 16030 25
16035 Dial, 0-150 A, for iAMP 16030 25
16036 Dial, 0-200 A, for iAMP 16030 25
16037 Dial, 0-250 A, for iAMP 16030 25
16038 Dial, 0-300 A, for iAMP 16030 25
16039 Dial, 0-400 A, for iAMP 16030 25
16040 Dial, 0-500 A, for iAMP 16030 25
16041 Dial, 0-600 A, for iAMP 16030 25
16042 Dial, 0-800 A, for iAMP 16030 25
16043 Dial, 0-1000 A, for iAMP 16030 25
16044 Dial, 0-1500 A, for iAMP 16030 25
16045 Dial, 0-2000 A, for iAMP 16030 25
16060 iVLT analogue voltmeter (0-300 V), DIN rail 25
16061 iVLT analogue voltmeter (0-500 V), DIN rail 25
16073 AMP analogue ammeter, 96 x 96, for motor feeder
(delivered without dial)
25
16074 AMP analogue ammeter, 96 x 96, for standard feeder
(delivered without dial)
25
16075 VLT analogue voltmeter, 96 x 96 28
16076 Dial, 0-30-90 A, for AMP 16073 28
16077 Dial, 0-75-225 A, for AMP 16073 28
16078 Dial, 0-200-600 A, for AMP 16073 28
16079 Dial, 0-50 A, for AMP 16074 28
16080 Dial, 0-100 A, for AMP 16074 28
16081 Dial, 0-200 A, for AMP 16074 28
16082 Dial, 0-400 A, for AMP 16074 28
16083 Dial, 0-600 A, for AMP 16074 28
16084 Dial, 0-1000 A, for AMP 16074 28
16085 Dial, 0-1250 A, for AMP 16074 28
16086 Dial, 0-1500 A, for AMP 16074 28
16087 Dial, 0-2000 A, for AMP 16074 28
16088 Dial, 0-2500 A, for AMP 16074 28
16089 Dial, 0-3000 A, for AMP 16074 28
16090 Dial, 0-4000 A, for AMP 16074 28
16091 Dial, 0-5000 A, for AMP 16074 28
16092 Dial, 0-6000 A, for AMP 16074 28
16500
16550 Adapter for DIN rails 44x66x37 16
16551 Adapter for DIN rails 56x84x60 19
16552 Lead-sealable cover for TC transformer 19
16553 Lead-sealable cover for TC transformer 19
A
A9MEM2000 iME2000 single-phase kilowatt-hour meter 35
A9MEM2010 iME2010 single-phase kilowatt-hour meter 35
A9MEM2100 iEM2100 basic energy meter 35
Cat. no. Description Page
A9MEM2105 iEM2105 energy meter, kWh pulse output with partial
meter
35
A9MEM2110 iEM2110 energy meter, kWh and kvarh pulse outputs
with two tariffs, four quadrant, energy measurement,
MID certied
35
A9MEM2135 iEM2135 energy meter, M-Bus communication, four
quadrant energy measurement, two tariffs, MID
certied
35
A9MEM2150 iEM2150 energy meter, Modbus communication, four
quadrant energy, measurement
35
A9MEM2155 iEM2155 energy meter, Modbus communication, four
quadrant energy measurement, two tariffs, MID
certied
35
A9MEM3100 iEM3100 basic energy meter 42
A9MEM3110 iEM3110 energy meter with pulse output 42
A9MEM3115 iEM3115 multi-tariff energy meter 42
A9MEM3135 iEM3135 advanced multi-tariff energy meter &
electrical parameter plus M-Bus comm port
42
A9MEM3150 iEM3150 energy meter & electrical parameter
plus Modbus RS485 comm port
42
A9MEM3155 iEM3155 advanced multi-tariff energy meter & electrical
parameter plus Modbus RS485 comm port
42
A9MEM3165 iEM3165 advanced multi-tariff energy meter & electrical
parameter plus Modbus, BACnet MS/ TP comm port
42
A9MEM3175 iEM3175 advanced multi-tariff energy meter & electrical
parameter plus LON TP/FT-10 comm port
42
A9MEM3200 iEM3200 basic energy meter 42
A9MEM3210 iEM3210 energy meter with pulse output 42
A9MEM3215 iEM3215 multi-tariff energy meter 42
A9MEM3235 iEM3235 advanced multi-tariff energy meter &
electrical parameter plus M-Bus comm port
42
A9MEM3250 iEM3250 energy meter & electrical parameter plus
RS485 comm port
42
A9MEM3255 iEM3255 advanced multi-tarrif energy meter &
electrical parameter plus RS485 comm port
42
A9MEM3265 iEM3265 advanced multi-tariff energy meter & electrical
parameter plus Modbus, BACnet MS/ TP comm port
42
A9MEM3275 iEM3275 advanced multi-tariff energy meter & electrical
parameter plus LON TP/FT-10 comm port
42
A9MEM3300 iEM3300 basic energy meter, direct connect 125 A 42
A9MEM3310 iEM3310 energy meter with pulse output 42
A9MEM3335 iEM3335 advanced multi-tariff energy meter &
electrical parameter plus M-Bus comm port
42
A9MEM3350 iEM3350 energy meter & electrical parameter
plus Modbus RS485 comm port
42
A9MEM3355 iEM3355 advanced multi-tariff energy meter &
electrical parameter plus Modbus RS485 comm port
42
A9MEM3365 iEM3365 advanced multi-tariff energy meter &
electrical parameter plus BACnet MS/TP comm port
42
A9MEM3375 iEM3375 advanced multi-tariff energy meter &
electrical parameter plus LON TP/FT-10 comm port
42
B
BCPMA042S 42 circuit BCPM 3/4" CT spacing - Advanced 48
BCPMA084S 84 circuit BCPM 3/4" CT spacing - Advanced 48
BCPMA142S 44 circuit BCPM 1" CT spacing - Advanced 48
BCPMA184S 84 circuit BCPM 1" CT spacing - Advanced 48
BCPMB042S 42 circuit BCPM 3/4" CT spacing - Intermediate 48
BCPMB084S 84 circuit BCPM 3/4" CT spacing - Intermediate 48
BCPMB142S 42 circuit BCPM 3/4" CT spacing - Intermediate 48
BCPMB184S 84 circuit BCPM 1" CT spacing - Intermediate 48
BCPMC042S 42 circuit BCPM 3/4" CT spacing - Basic 48
BCPMC084S 84 circuit BCPM 3/4" CT spacing - Basic 48
BCPMC142S 42 circuit BCPM 1" CT spacing - Basic 48
BCPMC184S 84 circuit BCPM 1" CT spacing - Basic 48
BCPMCOVERS Circuit board cover BCPM 48
BCPMSCA30S 30 split-core CTs, Advanced BCPM 48
BCPMSCA42S 42 split-core CTs, Advanced BCPM 48
BCPMSCA60S 60 split-core CTs, Advanced BCPM 48
BCPMSCA84S 84 split-core CTs, Advanced BCPM 48
BCPMSCADPBS
Adapter bord, for split core BCPM 48
BCPMSCB30S 30 split-core CTs, Intermediate BCPM 48
BCPMSCB42S 42 split-core CTs, Intermediate BCPM 48
BCPMSCB60S 60 split-core CTs, Intermediate BCPM 48
BCPMSCB84S 84 split-core CTs, Intermediate BCPM 48
14 PLSED309005EN
Index of catalogue numbers
(cont.)
BCPMSCC30S 30 split-core CTs, Basic BCPM 48
BCPMSCC42S 42 split-core CTs, Basic BCPM 48
BCPMSCC60S 60 split-core CTs, Basic BCPM 48
BCPMSCC84S 84 split-core CTs, Basic BCPM 48
BCPMSCCT0 Split core CTs, BCPM 50 A 50
BCPMSCCT0R20
Split core CTs, BCPM 50 A 50
BCPMSCCT1 Split core CTs, BCPM 100 A 50
BCPMSCCT1R20
Split core CTs, BCPM 100 A 50
BCPMSCCT3 Split core CTs, BCPM 200 A 50
BCPMSCCT3R20
Split core CTs, BCPM 200 A 50
C
CAB4 PM/CM <-> display connection cable (1.25 m) 87
CAB12 PM/CM <-> display connection cable (3.65 m) 87
CAB30 PM/CM <-> display connection cable (9.14 m) 87
CBL008 Fiat Ribbon cable for BCPM 50
CBL016
Fiat Ribbon cable for BCPM 50
CBL017 Fiat Ribbon cable for BCPM 50
CBL018 Fiat Ribbon cable for BCPM 50
CBL019 Fiat Ribbon cable for BCPM 50
CBL020
Fiat Ribbon cable for BCPM 50
CBL021 Fiat Ribbon cable for BCPM 50
CBL022 Round Ribbon cable for BCPM 50
CBL023 Round Ribbon cable for BCPM 50
CBL024 Round Ribbon cable for BCPM 50
CM4MA Mounting adaptor for CM4000T 107
E
EBX200 Com'X 200 Ethernet data logger 132
EBXA-USB-WIFI
Com'X 200 WiFi USB stick 132
EBXA-GPRS-SIM
Com'X 200 GPRS modem with SIM card 132
EBXA-GPRS Com'X 200 GPRS modem without SIM card 132
EBXA-ANT-5M Com'X 200 External GPRS antenna 132
EGX100MG EGX100 Ethernet gateway 137
EGX100SD EGX100 Ethernet gateway 137
EGX300 EGX300 Ethernet server 139
L
LVCT00102S
100 A 50
LVCT00202S
200 A 50
LVCT00302S
300 A 50
LVCT00403S
400 A 50
LVCT00603S
600 A 50
LVCT00803S
800 A 50
LVCT00804S
800 A 50
LVCT01004S
1000 A 50
LVCT01204S
1200 A 50
LVCT01604S
1600 A 50
LVCT02004S
2000 A 50
LVCT02404S
2400 A 50
M
M7550 ION7550 energy and power quality meter 100
M7650 ION7650 energy and power quality meter 100
M765RD ION7550 remote display 100
M765RDPS ION7550 remote display with power supply 100
M8650A ION8650A energy and power quality meter 114
M8650B ION8650B energy and power quality meter 114
M8650C ION8650C energy and power quality meter 114
M8800A ION8800A energy and power quality meter 122
M8800B ION8800B energy and power quality meter 122
M8800C ION8800C energy and power quality meter 122
METSECT5CC004
Type C - CT (cable prole) 40A 18
METSECT5CC005
Type C - CT (cable prole) 50A 18
METSECT5CC006
Type C - CT (cable prole) 60A 18
METSECT5CC008
Type C - CT (cable prole) 75A 18
METSECT5CC010
Type C - CT (cable prole) 100A 18
METSECT5CC013
Type C - CT (cable prole) 125A 18
METSECT5CC015
Type C - CT (cable prole) 150A 18
METSECT5CC020
Type C - CT (cable prole) 200A 18
METSECT5CC025
Type C - CT (cable prole) 250A 18
METSECT5ME015
Type ME - CT (mixed: cable/bar prole) 150A 18
METSECT5ME020
Type ME - CT (mixed: cable/bar prole) 200A 18
METSECT5ME025
Type ME - CT (mixed: cable/bar prole) 250A 18
METSECT5ME030
Type ME - CT (mixed: cable/bar prole) 300A 18
METSECT5ME040
Type ME - CT (mixed: cable/bar prole) 400A 18
METSECT5ME050
Type ME - CT (mixed: cable/bar prole) 500A 18
METSECT5ME060
Type ME - CT (mixed: cable/bar prole) 600A 18
METSECT5MB025
Type MB - CT (mixed: cable/bar prole) 250A 18
METSECT5MB030
Type MB- CT (mixed: cable/bar prole) 300A 18
METSECT5MB040
Type MB - CT (mixed: cable/bar prole) 400A 18
METSECT5MA015
Type MA - CT (mixed: cable/bar prole) 150A 18
METSECT5MA020
Type MA - CT (mixed: cable/bar prole) 200A 18
METSECT5MA025
Type MA - CT (mixed: cable/bar prole) 250A 18
METSECT5MA030
Type MA - CT (mixed: cable/bar prole) 300A 18
METSECT5MA040
Type MA - CT (mixed: cable/bar prole) 400A 18
METSECT5MC025
Type MC - CT (mixed: cable/bar prole) 250A 18
METSECT5MC030
Type MC - CT (mixed: cable/bar prole) 300A 18
METSECT5MC040
Type MC - CT (mixed: cable/bar prole) 400A 18
METSECT5MC050
Type MC - CT (mixed: cable/bar prole) 500A 18
METSECT5MC060
Type MC - CT (mixed: cable/bar prole) 600A 18
METSECT5MC080
Type MC - CT (mixed: cable/bar prole) 800A 18
METSECT5MF025
Type MF - CT (mixed: cable/bar prole) 250A 18
METSECT5MF030
Type MF - CT (mixed: cable/bar prole) 300A 18
METSECT5MF040
Type MF - CT (mixed: cable/bar prole) 400A 18
METSECT5MF050
Type MF - CT (mixed: cable/bar prole) 500A 18
METSECT5MD050
Type MD - CT (mixed: cable/bar prole) 500A 18
METSECT5MD060
Type MD - CT (mixed: cable/bar prole) 600A 18
METSECT5MD080
Type MD - CT (mixed: cable/bar prole) 800A 18
METSECT5CYL1
Accessory cylinder 1 19
METSECT5COVER
Sealable cover 19
METSECT5CYL2
Accessory cylinder 2 19
METSECT5VF050
Type VF CT (vertical bar prole) 500A 20
METSECT5VF060
Type VF CT (vertical bar prole) 600A 20
METSECT5VV500
Type VV CT (vertical bar prole) 5000A 20
METSECT5VV600
Type VV CT (vertical bar prole) 6000A 20
METSECT5DA020
Type DA - CT (vertical or horizontal bar - dual secondary
terminals) 200A
20
METSECT5DA025
Type DA - CT (vertical or horizontal bar - dual secondary
terminals) 250A
20
METSECT5DA030
Type DA - CT (vertical or horizontal bar - dual secondary
terminals) 300A
20
METSECT5DA040
Type DA - CT (vertical or horizontal bar - dual secondary
terminals) 400A
20
METSECT5DA050
Type DA - CT (vertical or horizontal bar - dual secondary
terminals) 500A
20
METSECT5DA060
Type DA - CT (vertical or horizontal bar - dual secondary
terminals) 600A
20
METSECT5DA080
Type DA - CT (vertical or horizontal bar - dual secondary
terminals) 800A
20
METSECT5DA100
Type DA - CT (vertical or horizontal bar - dual secondary
terminals) 1000A
20
METSECT5DA125
Type DA - CT (vertical or horizontal bar - dual secondary
terminals) 1250A
20
METSECT5DA150
Type DA - CT (vertical or horizontal bar - dual secondary
terminals) 1500A
20
METSECT5DB100
Type DB - CT (vertical or horizontal bar - dual secondary
terminals) 1000A
20
METSECT5DB125
Type DB - CT (vertical or horizontal bar - dual secondary
terminals) 1250A
20
METSECT5DB150
Type DB - CT (vertical or horizontal bar - dual secondary
terminals) 1500A
20
METSECT5DB200
Type DB - CT (vertical or horizontal bar - dual secondary
terminals) 2000A
20
METSECT5DB250
Type DB - CT (vertical or horizontal bar - dual secondary
terminals) 2500A
20
METSECT5DB300
Type DB - CT (vertical or horizontal bar - dual secondary
terminals) 3000A
20
METSECT5DC200
Type DC - CT (vertical or horizontal bar - dual secondary
terminals) 2000A
20
METSECT5DC250
Type DC - CT (vertical or horizontal bar - dual secondary
terminals) 2500A
20
METSECT5DC300
Type DC - CT (vertical or horizontal bar - dual secondary
terminals) 3000A
20
METSECT5DC400
Type DC - CT (vertical or horizontal bar - dual secondary
terminals) 4000A
20
Index of catalogue numbers
(cont.)
15
PLSED309005EN
Index of catalogue numbers
METSECT5DD100
Type DD - CT (vertical or horizontal bar - dual secondary
terminals) 1000A
20
METSECT5DD125
Type DD - CT (vertical or horizontal bar - dual secondary
terminals) 1250A
20
METSECT5DD150
Type DD - CT (vertical or horizontal bar - dual secondary
terminals) 1500A
20
METSECT5DE100
Type DE - CT (vertical or horizontal bar - dual secondary
terminals) 1000A
20
METSECT5DE125
Type DE - CT (vertical or horizontal bar - dual secondary
terminals) 1250A
20
METSECT5DE150
Type DE - CT (vertical or horizontal bar - dual secondary
terminals) 1500A
20
METSECT5DE200
Type DE - CT (vertical or horizontal bar - dual secondary
terminals) 2000A
20
METSECT5DH125
Type DH - CT (vertical or horizontal bar - dual secondary
terminals) 1250A
20
METSECT5DH150
Type DH - CT (vertical or horizontal bar - dual secondary
terminals) 1500A
20
METSECT5DH200
Type DH - CT (vertical or horizontal bar - dual secondary
terminals) 2000A
20
METSEEM480525
PowerLogic E4800 multi-circuit energy meter 58
METSEEM488025
PowerLogic E4800 multi-circuit energy meter 58
METSEEM480516
PowerLogic E4800 multi-circuit energy meter 58
METSEEM488016
PowerLogic E4800 multi-circuit energy meter 58
METSEEM480526
PowerLogic E4800 multi-circuit energy meter 58
METSEEM488026
PowerLogic E4800 multi-circuit energy meter 58
METSEPM3200 PM3200 basic power meter 61
METSEPM3210 PM3210 power meter with pulse output 61
METSEPM3250 PM3250 power meter with RS485 port 61
METSEPM3255 PM3255 power meter with 2 DI, 2 DO, RS485 port 61
METSEPM5100 PM5100 power meter 78
METSEPM5110 PM5110 power meter 78
METSEPM5111 PM5111 power meter 78
METSEPM5310 PM5310 power meter 78
METSEPM5320 PM5320 power meter 78
METSEPM5330 PM5330 power meter 78
METSEPM5331 PM5331 power meter 78
METSEPM5340 PM5340 power meter 78
METSEPM5341 PM5341 power meter 78
METSEPM5350 PM5350 power meter 78
METSEPM5560 PM5560 power meter 78
METSEPM5561 PM5561 power meter 78
METSEPM5563 PM5563 power meter 78
METSEPM8240 Panel mount meter 95
METSEPM8243 DIN rail mount meter 95
METSEPM8244 DIN rail mount meter + Remote display 95
METSEPM89RD96 display, 3 M cable, mounting hardware for 30mm hole 95
METSEPM8000SK Terminal covers and sealing instructions 95
METSEPMAK Adapters for mounting meter and RMD back to back 95
METSECAB1 Display Cable, 1 metre 95
METSECAB3 Display Cable, 3 metres 95
METSECAB10 Display Cable, 10 metres 95
METSEPM89M2600 I/O module, 6 self-wetted digital inputs & 2 Form-C
relay outputs
95
METSEPM89M0024 I/O module, 4 analogue inputs, 2 analogue outputs 95
O
OPTICAL-PROBE
Optical communication interface 119
P
PM810LOG Optional logging module for on-board data recording
for PM810
87
PM810MG PM810 Power Meter with integrated display 86
PM810RDMG Meter and remote display kit 86
PM810UMG PM810 Power Meter without display 86
PM820MG PM820 Power Meter with integrated display 86
PM820RDMG Meter and remote display kit 86
PM820UMG PM820 Power Meter without display 86
PM850MG PM850 Power Meter with integrated display 86
PM850RDMG Meter and remote display kit 86
PM850UMG PM850 Power Meter without display 86
PM870MG PM870 Power Meter with integrated display 86
PM870RDMG Meter and remote display kit 86
PM870UMG PM870 Power Meter without display 86
PM8ECC PM8ECC module for PM Series 800 87
PM8M22 PM8M22 module for PM Series 800 87
PM8M26 PM8M26 module for PM Series 800 87
PM8M2222 PM8M2222 module for PM Series 800 87
PM8RDA Remote display and adapter alone 86
PM8RDMG Remote display and adapter with a 3.55 m cable 86
R
RJ11EXT RJ11 Extender kit to mount RJ11 jack in panel door
16 PLSED309005EN
CT current transformers
Ip/5 A ratio
Current transformers
The Ip/5A ratio current transformer delivers at the secondary a current (Is) of 0 to 5 A
that is proportional to the current measured at the primary (Ip).
This allows them to be used in combination with measurement equipment:
b Ammeters.
b Kilowatt-hour meters.
b Measurement units.
b Control relays.
b etc.
When the primary is energized, the measurement equipment nearly acts as a short
circuit which keeps the secondary voltage very low. This voltage will increases
signicantly if the short circuit is removed.
CT selection - conductor rating aspects
The choice depends on the conductor prole and the maximum intensity
of the primary circuit.
CT with let-through primary
Conductor type Cable Mixed, bars or cables Vertical or horizontal bars Vertical bars
Suggested
Current
Transformer
and mounting
DB415986.eps
DB415920.eps
DB415988.eps
DB415989.eps
DB415921.eps
DB415987.eps
Ratings (A) 40 to 250 150 to 800 200 to 4000 500 to 600 5000 to 6000
CT internal
prole
Type C Type M Type D (1) Type V
MA
MB
MC
VF VV
MD
ME
MF
(1) Two secondary connectors (parallel internal wiring - only one secondary winding) for easier
cable access. 1 lateral + 1 on one extremity. Warning: only one must be used at a time.
Specific mounting: use of cylinder
A cylindrical metallic spacer ensures a proper CT positioning when the conductor or
the CT cannot be positioned perpendicular. Secured by bolt + nut.
CT with primary connection by screw and nut
(example: use of cylinder with bar or cable)
DB416006.eps
DB416005.eps
16550 (brass) METSECT5CYL1 (aluminium)
Ip Is
Primary
circuit
Secondary
circuit
N
Ph
Measurement
equipment
Load
DB416186.eps
Application diagram of a CT.
17
PLSED309005EN
CT current transformers (cont.)
Ip/5 A ratio
Current transformers
CT selection - Electrical aspect Ip/5 A
b We recommend that you choose the ratio immediately higher than the maximum
measured current (In).
Example:
In = 1103 A; ratio chosen = 1250/5.
b For small ratings:
from 40/5 to 75/5 and for an application with digital devices, we recommend
that you choose a higher rating, for example 100/5.
This is because small ratings are less accurate and the 40 A measurement,
for example, will be more accurate with a 100/5 CT than with a 40/5 CT.
b Specic case of the motor starter:
to measure motor starter current, you must choose a CT with primary current
Ip = Id/2 (Id = motor starting current).
Validation of measurement solution according
accuracy class
It consists in controlling the right adaptation of the CT on the assucary class aspect.
The accuracy class is specied in the project. The total dissipated power of the
measurement circuit (meter + cables) should not be superior to the specied limit of
the CT. This limit is for different standard classes. If necessary, the choice of the
cable section, the CT or meter should be modify to t the requirement.
Copper cable
cross-section
(mm2)
Power per doubled
meter at 20 °C
(VA)
Schneider Electric
device
Consumption of
the current input
(VA)
Ammeter
72 x 72 / 96 x 96
1.1
Analogue ammeter 1.1
Digital ammeter 0.3
PM700, PM800 0.15
PM3000 0.3
11
1.5 0.685
2.5 0.41
40.254
60.169
10 0.0975
16 0.062
For each temperature variation per 10 °C
bracket, the power drawn up by the cables
increases by 4 %.
Application example
Project specication: 200 A, in Ø27 mm cable, accuracy class 1.
Our choice is METSECT5MA020.
For this CT selected on the chart (next page), the max acceptable power is 7 VA (for
"Accuracy class 1" which is specied in the project).
Internal
prole
type
Cables
(mm)
Bars
(mm)
Rating
Ip/5 A
(A)
Cat. no. Accuracy class
0.5 1 3
Max. power (VA)
MA
Ø27 10 x 32
15 x 25
150 METSECT5MA015 34-
200 METSECT5MA020 47-
250 METSECT5MA025 68-
300 METSECT5MA030 8 10 -
400 METSECT5MA040 10 12 -
Control of the conformity of the measurement chain:
b PM3000 multi-meter: 0.3 VA.
b 4 meters of 2.5 mm2, doubled wires: 0.41 x 4 = 1.64 VA.
Total: 0.3 + 1.64 = 1.94 VA (< 7 VA)
Conclusion: this CT is well adapted as the accuracy class will be even better than 1.
18 PLSED309005EN
Current transformers CT,
Ip/5 A ratio
Catalogue numbers
Presentation of catalogue numbers
First digit = secondary rating,
Examples:
b METSECT5CC008 = 5 A secondary, Cables only, 75 A primary
b METSECT5MC080 = 5 A secondary, Mixed for cables and bars, 800 A primary.
PB112446.eps
METSECT5CCppp
PB112464.eps
PB112461.eps
METSECT5MEppp METSECT5MBppp
PB112460.eps
PB112462.eps
METSECT5MAppp METSECT5MCppp
PB112465.eps
PB112463.eps
METSECT5MFppp METSECT5MDppp
MET SE CT R FF XXX
Type C - current transformer (cable prole)
Internal prole
type
Cables
(mm)
Bars
(mm)
Rating
Ip/5 A
(A)
Cat. no. Accuracy class Overall dimensions
(refer to drawing
pages for details)
W x H x D
(mm)
Fastening mode Accessories
0.5 1 3 Cylinder Sealable cover
Max. power (VA)
CC
Ø21 - 40 METSECT5CC004 --144 x 66 x 37 b Adapter for DIN rails.
b Mounting plate.
16550
METSECT5CYL1
Included
50 METSECT5CC005 - 1.25 1.5
60 METSECT5CC006 - 1.25 2
75 METSECT5CC008 - 1.5 2.5
100 METSECT5CC010 2 2.5 3.5
125 METSECT5CC013 2.5 3.5 4
150 METSECT5CC015 345
200 METSECT5CC020 4 5.5 6
250 METSECT5CC025 567
Type M - current transformers (mixed: cable/bar prole)
ME
Ø22 10 x 30
11 x 25
12 x 20
150 METSECT5ME015 1.5 5.5 6.5 56 x 84 x 60 b Adapter for DIN rails.
b Mounting plate.
b Insulated locking screw.
16551 16552
200 METSECT5ME020 4 7 8.5
250 METSECT5ME025 6911
300 METSECT5ME030 7.5 11 14
400 METSECT5ME040 10.5 15 18
500 METSECT5ME050 12 18 22
600 METSECT5ME060 14.5 21.5 26
MB
Ø26 12 x 40
15 x 32
250 METSECT5MB025 34- 60 x 85 x 63 b Adapter for DIN rails.
b Mounting plate.
- METSECT5COVER
300 METSECT5MB030 46-
400 METSECT5MB040 68-
MA
Ø27 10 x 32
15 x 25
150 METSECT5MA015 34- 56 x 80 x 63 b Adapter for DIN rails.
b Mounting plate.
METSECT5CYL2 METSECT5COVER
200 METSECT5MA020 47-
250 METSECT5MA025 68-
300 METSECT5MA030 8 10 -
400 METSECT5MA040 10 12 -
MC
Ø32 10 x 40
20 x 32
25 x 25
250 METSECT5MC025 35- 70 x 95 x 65 b Adapter for DIN rails.
b Mounting plate.
- METSECT5COVER
300 METSECT5MC030 58-
400 METSECT5MC040 8 10 -
500 METSECT5MC050 10 12 -
600 METSECT5MC060 12 15 -
800 METSECT5MC080 10 12 -
MF
Ø35 10 x 40 250 METSECT5MF025 2.5 5 8 77 x 107 x 64 b Adapter for DIN rails.
b Mounting plate.
b Insulated locking screw.
- 16553
300 METSECT5MF030 4 8 12
400 METSECT5MF040 8 12 15
500 METSECT5MF050 10 12 15
MD
19
PLSED309005EN
Type C - current transformer (cable prole)
Internal prole
type
Cables
(mm)
Bars
(mm)
Rating
Ip/5 A
(A)
Cat. no. Accuracy class Overall dimensions
(refer to drawing
pages for details)
W x H x D
(mm)
Fastening mode Accessories
0.5 1 3 Cylinder Sealable cover
Max. power (VA)
CC
Ø21 - 40 METSECT5CC004 --144 x 66 x 37 b Adapter for DIN rails.
b Mounting plate.
16550
METSECT5CYL1
Included
50 METSECT5CC005 - 1.25 1.5
60 METSECT5CC006 - 1.25 2
75 METSECT5CC008 - 1.5 2.5
100 METSECT5CC010 2 2.5 3.5
125 METSECT5CC013 2.5 3.5 4
150 METSECT5CC015 345
200 METSECT5CC020 4 5.5 6
250 METSECT5CC025 567
Type M - current transformers (mixed: cable/bar prole)
ME
Ø22 10 x 30
11 x 25
12 x 20
150 METSECT5ME015 1.5 5.5 6.5 56 x 84 x 60 b Adapter for DIN rails.
b Mounting plate.
b Insulated locking screw.
16551 16552
200 METSECT5ME020 4 7 8.5
250 METSECT5ME025 6911
300 METSECT5ME030 7.5 11 14
400 METSECT5ME040 10.5 15 18
500 METSECT5ME050 12 18 22
600 METSECT5ME060 14.5 21.5 26
MB
Ø26 12 x 40
15 x 32
250 METSECT5MB025 34- 60 x 85 x 63 b Adapter for DIN rails.
b Mounting plate.
- METSECT5COVER
300 METSECT5MB030 46-
400 METSECT5MB040 68-
MA
Ø27 10 x 32
15 x 25
150 METSECT5MA015 34- 56 x 80 x 63 b Adapter for DIN rails.
b Mounting plate.
METSECT5CYL2 METSECT5COVER
200 METSECT5MA020 47-
250 METSECT5MA025 68-
300 METSECT5MA030 8 10 -
400 METSECT5MA040 10 12 -
MC
Ø32 10 x 40
20 x 32
25 x 25
250 METSECT5MC025 35- 70 x 95 x 65 b Adapter for DIN rails.
b Mounting plate.
- METSECT5COVER
300 METSECT5MC030 58-
400 METSECT5MC040 8 10 -
500 METSECT5MC050 10 12 -
600 METSECT5MC060 12 15 -
800 METSECT5MC080 10 12 -
MF
Ø35 10 x 40 250 METSECT5MF025 2.5 5 8 77 x 107 x 64 b Adapter for DIN rails.
b Mounting plate.
b Insulated locking screw.
- 16553
300 METSECT5MF030 4 8 12
400 METSECT5MF040 8 12 15
500 METSECT5MF050 10 12 15
MD
Common characteristics
Secondary current Is (A) 5
Maximum voltage rating Ue (V) 720
Frequency (Hz) 50/60
Safety factor (sf) b 40 to 4000 A: sf y 5
b 5000 to 6000 A: sf y 10
Degree of protection IP20
Operating temperature b tropicalised range
b -25 °C to +60 °C (1)
b relative humidity > 95 %
Compliance with standards b IEC 61869-2
b VDE 0414
Secondary connection (as per model) b by terminals for lug
b by tunnel terminals
b by screws
(1) Warning: some products are limited to +50 °C.
DIN rail mounting.
DB415927.eps DB415926.eps
Mounting plate installation.
CT,
Ip/5 A ratio
Catalogue numbers
Current transformers
20 PLSED309005EN
Current transformers CT,
Ip/5 A ratio
Catalogue numbers
PB112466.eps
PB112467.eps
METSECT5VFppp METSECT5VVppp
PB112454.eps
PB112455.eps
METSECT5DAppp METSECT5DBppp
PB112456.eps
PB112457.eps
METSECT5DCppp METSECT5DDppp
PB112458.eps
PB112459.eps
METSECT5DEppp METSECT5DHppp
Type V current transformers (vertical bar prole)
Internal prole
type
Cables
(mm)
Bars
(mm)
Rating
Ip/5 A
(A)
Cat. no. Accuracy class Overall dimensions
(refer to drawing
pages for details)
W x H x D
(mm)
Fastening mode Accessories
0.5 1 3 Cylinder Sealable cover
Max. power
(VA)
VF
-11 x 64
31 x 51
500 METSECT5VF050 24- 90 x 130 x 66 b Mounting plate.
b Insulated locking screw.
- Included
600 METSECT5VF060 46-
VV
-55 x 165 5000 METSECT5VV500 g60 - - 175 x 273.5 x 110 b Insulated locking screw. - Included
6000 METSECT5VV600 g70 - -
Type D - current transformers
(vertical or horizontal bar - dual secondary terminals)
DA
-32 x 65 200 METSECT5DA020 - 2590 x 94 x 90 b Insulated locking screw. - Included
250 METSECT5DA025 14-
300 METSECT5DA030 1.5 6 -
400 METSECT5DA040 48-
500 METSECT5DA050 8 10 -
600 METSECT5DA060 8 12 -
800 METSECT5DA080 12 15 -
1000 METSECT5DA100 15 20 -
1250 METSECT5DA125 g15 20 -
1500 METSECT5DA150 g20 25 -
DB
-38 x 127 1000 METSECT5DB100 6 10 - 99 x 160 x 87 b Insulated locking screw. - Included
1250 METSECT5DB125 g8 12 -
1500 METSECT5DB150 g10 15 -
2000 METSECT5DB200 g15 20 -
2500 METSECT5DB250 g20 25 -
3000 METSECT5DB300 g25 30 -
DC
-52 x 127 2000 METSECT5DC200 g25 30 - 125 x 160 x 87 b Insulated locking screw. - Included
2500 METSECT5DC250 g30 50 -
3000 METSECT5DC300 g30 50 -
4000 METSECT5DC400 g30 50 -
DD
-34 x 84 1000 METSECT5DD100 10 15 - 96 x 116 x 87 b Insulated locking screw. - Included
1250 METSECT5DD125 g12 15 -
1500 METSECT5DD150 g15 20 -
DE
-54 x 102 1000 METSECT5DE100 12 15 - 135 x 129 x 85 b Insulated locking screw. - Included
1250 METSECT5DE125 g15 20 -
1500 METSECT5DE150 g20 25 -
2000 METSECT5DE200 g20 25 -
DH
-38 x 102 1250 METSECT5DH125 g12 15 - 98 x 129 x 75 b Insulated locking screw. - Included
1500 METSECT5DH150 g12 15 -
2000 METSECT5DH200 g20 25 -
g Operating temperature: -25 °C to +50 °C.
21
PLSED309005EN
Type V current transformers (vertical bar prole)
Internal prole
type
Cables
(mm)
Bars
(mm)
Rating
Ip/5 A
(A)
Cat. no. Accuracy class Overall dimensions
(refer to drawing
pages for details)
W x H x D
(mm)
Fastening mode Accessories
0.5 1 3 Cylinder Sealable cover
Max. power
(VA)
VF
-11 x 64
31 x 51
500 METSECT5VF050 24- 90 x 130 x 66 b Mounting plate.
b Insulated locking screw.
- Included
600 METSECT5VF060 46-
VV
-55 x 165 5000 METSECT5VV500 g60 - - 175 x 273.5 x 110 b Insulated locking screw. - Included
6000 METSECT5VV600 g70 - -
Type D - current transformers
(vertical or horizontal bar - dual secondary terminals)
DA
-32 x 65 200 METSECT5DA020 - 2590 x 94 x 90 b Insulated locking screw. - Included
250 METSECT5DA025 14-
300 METSECT5DA030 1.5 6 -
400 METSECT5DA040 48-
500 METSECT5DA050 8 10 -
600 METSECT5DA060 8 12 -
800 METSECT5DA080 12 15 -
1000 METSECT5DA100 15 20 -
1250 METSECT5DA125 g15 20 -
1500 METSECT5DA150 g20 25 -
DB
-38 x 127 1000 METSECT5DB100 6 10 - 99 x 160 x 87 b Insulated locking screw. - Included
1250 METSECT5DB125 g8 12 -
1500 METSECT5DB150 g10 15 -
2000 METSECT5DB200 g15 20 -
2500 METSECT5DB250 g20 25 -
3000 METSECT5DB300 g25 30 -
DC
-52 x 127 2000 METSECT5DC200 g25 30 - 125 x 160 x 87 b Insulated locking screw. - Included
2500 METSECT5DC250 g30 50 -
3000 METSECT5DC300 g30 50 -
4000 METSECT5DC400 g30 50 -
DD
-34 x 84 1000 METSECT5DD100 10 15 - 96 x 116 x 87 b Insulated locking screw. - Included
1250 METSECT5DD125 g12 15 -
1500 METSECT5DD150 g15 20 -
DE
-54 x 102 1000 METSECT5DE100 12 15 - 135 x 129 x 85 b Insulated locking screw. - Included
1250 METSECT5DE125 g15 20 -
1500 METSECT5DE150 g20 25 -
2000 METSECT5DE200 g20 25 -
DH
-38 x 102 1250 METSECT5DH125 g12 15 - 98 x 129 x 75 b Insulated locking screw. - Included
1500 METSECT5DH150 g12 15 -
2000 METSECT5DH200 g20 25 -
g Operating temperature: -25 °C to +50 °C.
CT,
Ip/5 A ratio
Catalogue numbers
Current transformers
22 PLSED309005EN
CT current transformers (cont.)
Ip/5 A ratio
Current transformers
CT current transformers
CC internal prole type ME internal prole type MB internal prole type
44
66
Ø21
27.5
30
37
DB416965.eps
56
Ø22 84
31
42
60
DB415934.eps
60
Ø26 85
33.5
43
63
DB415923.eps
MA internal prole type MC internal prole type MF internal prole type
56
Ø27 80
30.5
43
63
DB415922.eps
70
41
41
95
45
65
DB415939.eps
77
40.5
Ø35
107
43
46
64
DB415935.eps
MD internal prole type DA internal prole type
70
Ø40
95
40
45
65
DB416966.eps
90
40
94
65
32
90
DB415932.eps
DB internal prole type DC internal prole type
87
40
160
127
38
99
DB416967.eps
87
40
160
127
54
125
DB416968.eps
23
PLSED309005EN
CT current transformers (cont.)
Ip/5 A ratio
Current transformers
CT current transformers
DD internal prole type DE internal prole type
87
40
116
84
34
96
DB416969.eps
85
50
129
103
55
135
DB416970.eps
DH internal prole type
75
40
129
103
40
98
DB416971.eps
VV internal prole type VF internal prole type
110
242
165
175
273.5
DB416972.eps
90
66
48
113
31
11
64
51
130
DB416973.eps
24 PLSED309005EN
Cylinders
METSECT5CYL1 METSECT5CYL2
M8
Ø 21.5
32
21.5
DB416004.eps
M10
Ø 26
45
26.5
DB416002.eps
Aluminium Aluminium
16550 16551
Ø 8.5
Ø 22 32
22.5
DB416082.eps
Ø 12.5
Ø 22.5 63
22.5
DB416000.eps
Brass Brass
Covers
16552
82 58
31
DB415996.eps
16553
61 54.5
26
DB415998.eps
METSECT5COVER
60.5
22
23.5
DB416008.eps
CT current transformers (cont.)
Ip/5 A ratio
Current transformers
Panel instruments
Function
iAMP
Ammeters measure the current owing through an electric circuit in amps.
iVLT
Voltmeters measure the potential (voltage) difference of an electric circuit in volts.
Common technical data
bAccuracy: class 1.5.
b Complies with standards IEC 60051-1, IEC 61010-1 and IEC 61000-4.
b Ferromagnetic device.
b Pseudo-linear scale over 90°.
b Ammeters (except catalogue number 16029):
v connection on CT, ratio In/5, to be ordered separately
v interchangeable dials.
b Temperature:
v operating temperature: -25 °C to +55 °C.
v reference temperature: 23 °C.
b Inuence of temperature on accuracy: ±0.03 % / °C.
b Utilisation frequency: 50/60 Hz.
b Consumption:
v AMP: 1.1 VA
v VLT catalogue number 15060: 2.5 VA
v VLT catalogue number 16061: 3.5 VA.
b Permanent overload:
v AMP: 1.2 In
v VLT: 1.2 Un.
b Maximum overload for 5 s:
v AMP: 10 In
v VLT: 2 Un.
b Connection: tunnel terminals for 1.5 to 6 mm2 rigid cables.
Catalogue numbers
Type Scale Connection
with CT
Width in mod.
of 9 mm
Cat. no.
iAMP with direct connection
0-30 A no 8 16029
iAMP with connection on CT
Basic device
(delivered without dial)
X/5 8 16030
Dial 0-5 A 16031
0-50 A 50/5 16032
0-75 A 75/5 16033
0-100 A 100/5 16034
0-150 A 150/5 16035
0-200 A 200/5 16036
0-250 A 250/5 16037
0-300 A 300/5 16038
0-400 A 400/5 16039
0-500 A 500/5 16040
0-600 A 600/5 16041
0-800 A 800/5 16042
0-1000 A 1000/5 16043
0-1500 A 1500/5 16044
0-2000 A 2000/5 16045
iVLT
0-300 V 816060
0-500 V 816061
DB119006
iAMP.
DB119005
iVLT.
DIN rail analogue ammeters and
voltmeters
25
PLSED309005EN
Panel instruments
Function
iAMP
Ammeters measure in amps the current owing through an electric circuit.
iVLT
Voltmeters measure in volts the potential (voltage) difference of an electric circuit.
iFRE
The frequency meter measures in hertz the frequency of an electric circuit from 20 to
600 V AC.
Common technical data
b Supply voltage: 230 V.
bOperating frequency: 50/60 Hz.
bDisplay by red LED: 3 digits, h = 8 mm.
bAccuracy at full-scale : 0.5 % ±1 digit.
bConsumption: max. 5 VA or rated 2.5 VA.
b Degree of protection:
v IP40 on front face
v IP20 at terminal level.
bConnection: tunnel terminals for 2.5 mm2 cables.
Specic data
10 A direct reading ammeter
bMinimum value measured: 4 % of rating.
bMeasurement input consumption: 1 VA.
Multi-rating ammeter
bRatings:
v in direct reading: 5 A
v by CT (not supplied) congurable on the front face of the ammeter: 10, 15, 20, 25,
40, 50, 60, 100, 150, 200, 250, 400, 500, 600, 800, 1000, 1500, 2000, 2500, 4000,
5000 A.
bMinimum value measured: 4% of rating.
bMeasurement input consumption: 0.55 VA.
Voltmeter
bDirect measurement: 0...600 V.
bInput impedance: 2 MW.
bMinimum value measured: 4 % of rating.
Frequency meter
bMinimum value measured: 20 Hz.
bMaximum value measured: 100 Hz.
bFull-scale display: 99.9 Hz.
Compliance with standards
bSafety: IEC/EN 61010-1.
bEMC electromagnetic compatibility: IEC/EN 65081-1 and IEC/EN 65082-2.
Catalogue numbers
Type Scale Connection
with CT
Width in mod.
of 9 mm
Cat. no.
Direct reading iAMP
0-10 A No 4 15202
Multi-rating iAMP
0-5000 A As per rating 415209
iVLT
0-600 V 415201
iFRE
20-100 Hz 415208
PB112024
iAMP.
PB112023
iVLT.
PB112025
iFRE.
DIN rail digital ammeters,
voltmeter and frequency meter
26 PLSED309005EN
Function
The 72 x 72 measurement devices are designed for ush-mounted installation on
doors, wicket doors and front plates of enclosures and cubicles.
AMP
The ammeters measure in amps the current owing through an electrical circuit.
VLT
The voltmeter measure in volts the potential difference (voltage) of an electrical
circuit.
Common technical data
b Accuracy: class 1.5.
b Compliance with standard IEC 60051-1, IEC 61010-1 and IEC 61000-4.
b Ferromagnetic device.
b Scale length: 62 mm over 90°.
b Mounting in enclosure or in cubicle.
b Degree of protection: IP52.
b Maximum operating position: 30° / vertical.
b Temperature:
v operation: -25 °C to +50 °C
v reference: 23 °C.
b Inuence of temperature on accuracy: ±0.003 % / °C.
b Utilisation frequency: 50/60 Hz.
AMP specic technical data
b Needs a In/5 CT to be ordered separately.
b Interchangeable dials to be ordered separately.
b Consumption: 1.1 VA.
b Permanent overload: 1.2 In.
b Maximum overload for 5 s: 10 In.
VLT specic technical data
b Consumption: 3 VA.
b Permanent overload: 1.2 Un.
b Maximum overload for 5 s: 2 Un.
Catalogue numbers
Type Scale Connection
on CT
Cat. no.
AMP for standard feeder
Basic device (delivered without dial) X/5 16004
1.3 In dial 0-50 A 50/5 16009
0-100 A 100/5 16010
0-200 A 200/5 16011
0-400 A 400/5 16012
0-600 A 600/5 16013
0-1000 A 1000/5 16014
0-1250 A 1250/5 16015
0-1500 A 1500/5 16016
0-2000 A 2000/5 16019
AMP for motor feeder
Basic device (delivered without dial) X/5 16003
3 In dial 0-30-90 A 30/5 16006
0-75-225 A 75/5 16007
0-200-600 A 200/5 16008
VLT
0-500 V 16005
PB101118-30_c
AMP for standard feeder.
PB101119-30_c
AMP for motor feeder.
PB101116-30_c
VLT.
Panel instruments 72 x 72 analogue ammeters and
voltmeter
27
PLSED309005EN
28 PLSED309005EN
Function
The 96 x 96 measurement devices are designed for ush-mounted installation on
doors, wicket doors and front plates of enclosures and cubicles.
AMP
The ammeters measure in amps the current owing through an electrical circuit.
VLT
The voltmeter measure in volts the potential difference (voltage) of an electrical
circuit.
Common technical data
b Accuracy: class 1.5.
b Compliance with standard IEC 60051-1, IEC 61010-1 and IEC 61000-4.
b Ferromagnetic device.
b Scale length: 80 mm over 90°.
b Mounting in enclosure or in cubicle.
b Degree of protection: IP52.
b Maximum operating position: 30° / vertical.
b Temperature:
v operation: -25 °C to +50 °C
v reference: 23 °C.
b Inuence of temperature on accuracy: ±0.003 % / °C.
b Utilisation frequency: 50/60 Hz.
AMP specic technical data
b Needs a In/5 CT to be ordered separately.
b Interchangeable dials to be ordered separately.
b Consumption: 1.1 VA.
b Permanent overload: 1.2 In.
b Maximum overload for 5 s: 10 In.
VLT specic technical data
b Consumption: 3 VA.
b Permanent overload: 1.2 Un.
b Maximum overload for 5 s: 2 Un.
Catalogue numbers
Type Scale Connection
on CT
Cat. no.
AMP for standard feeder
Basic device (delivered without dial) X/5 16074
1.3 In dial 0-50 A 50/5 16079
0-100 A 100/5 16080
0-200 A 200/5 16081
0-400 A 400/5 16082
0-600 A 600/5 16083
0-1000 A 1000/5 16084
0-1250 A 1250/5 16085
0-1500 A 1500/5 16086
0-2000 A 2000/5 16087
0-2500 A 2500/5 16088
0-3000 A 3000/5 16089
0-4000 A 4000/5 16090
0-5000 A 5000/5 16091
0-6000 A 6000/5 16092
AMP for motor feeder
Basic device (delivered without dial) X/5 16073
3 In dial 0-30-90 A 30/5 16076
0-75-225 A 75/5 16077
0-200-600 A 200/5 16078
VLT
0-500 V 16075
PB101118-40_c
AMP for standard feeder.
PB101119-40_c
AMP for motor feeder.
PB101116-40_c
VLT.
Panel instruments 96 x 96 analogue ammeters and
voltmeter
29
PLSED309005EN
Panel instruments
Function
The 48 x 48 selector switches are designed for ush-mounted installation on doors,
wicket doors and front plates of enclosures and cubicles.
CMA
The ammeter selector switch uses a single ammeter (by means of current
transformers) for successive measurement of the currents of a three-phase circuit.
CMV
The voltmeter selector switch uses a single voltmeter for successive measurement
of the voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit.
Common technical data
b Durability:
v electrical: 100 000 operations
v mechanical: 2 000 000 operations.
b AgNi contact.
b Operating temperature: -25 °C to +50 °C.
b Compliance with standards IEC/EN 60947-3.
b Degree of protection:
v IP65 on front face
v IP20 at terminal level.
Catalogue numbers
Type Rating
(A)
Voltage
(V)
Number of
positions
Cat. no.
CMA 20 4 16017
CMV 500 7 16018
Connection
DB117274
CMA.
DB114275
CMV.
Reading 3 phase-to-earth voltages + 3 phase-to-phase voltages.
Note: when connecting do not remove the pre-cabling.
050740-25_c
CMA.
050741-25_c
CMV.
48 x 48 CMA and CMV
selector switches
30 PLSED309005EN
DIN rail iCMA and iCMV selector
switches
Panel instruments
Function
iCMA
This 4-position ammeter selector switch uses a single ammeter (using current
transformers) for successive measurement of the currents of a three-phase circuit.
iCMV
This 7-position voltmeter selector switch uses a single voltmeter for successive
measurement of voltages (phase-to-phase and phase-to-neutral) of a three-phase
circuit.
Common technical data
b Rotary handle.
b Maximum operating voltage: 440 V, 50/60 Hz.
b Nominal thermal current: 10 A.
b Operating temperature: -20°C to +55°C.
b Storage temperature: -25°C to +80°C.
b Mechanical durability (AC21A-3 x 440 V): 2 000 000 operations.
b Degree of protection:
v IP66 on front face
v IP20 at terminal level.
b Electrical durability: 1 000 000 operations.
b Connection: jumper terminals with captive screws, for cables up to 1.5 mm2.
b Complies with standards: IEC/EN 60947-3.
Catalogue numbers
Type Rating
(A)
Voltage
(V AC)
Width in
mod. of 9 mm
Cat. no.
iCMA 10 415 4 15126
iCMV 10 415 4 15125
Connection
DB114272
iCMA.
DB114273
iCMV.
PB107119
iCMA.
PB107118
iCMV.
31
PLSED309005EN
Function
Electromechanical counter that counts the operating hours of a machine or piece of
electrical equipment. Giving a precise indication of operating time, the counter is
used to decide when to carry out preventive maintenance.
Common technical data
b Electromechanical display.
b Maximum display: 99999.99 hours.
b Display accuracy: 0.01 %.
b Without reset.
b Storage temperature: -25 °C to +85 °C.
b Connection: tunnel terminals for 2.5 mm2 cable.
Specic technical data
iCH "DIN"
b Consumption: 0.15 VA.
b Operating temperature: -10 °C to +70 °C.
b Mounting on DIN rail.
CH "48 x 48"
b Consumption:
v 15607: 0.25 VA
v 15608: 0.15 VA
v 15609: 0.02 VA to 12 V and 0.3 VA to 36 V.
b Operating temperature: -20 °C to + 70 °C.
b Degree of protection: IP65 on front face.
b Mounting on front face of monitoring switchboards.
Catalogue numbers
Type Voltage
(V)
Width in mod.
of 9 mm
Cat. no.
iCH "DIN" 230 V AC ± 10%/50 Hz 415440
CH "48 x 48" 24 V AC ± 10%/50 Hz 15607
230 V AC ± 10%/50 Hz 15608
12 to 36 V DC 15609
Connection
DB114262
DB114263
iCH "DIN". CH "48 x 48".
PB112026
iCH "DIN".
DB119003
CH "48 x 48".
load load
Panel instruments iCH hour counters
32 PLSED309005EN
iCI impulse counter
Function
Electromechanical counter designed to count impulses emitted by: kilowatt hour
meters, temperature overrun detectors, people meters, speed meters, etc.
Common technical data
b Supply and metering voltage: 230 V AC ± 10%, 50/60 Hz.
b Consumption: 0.15 VA.
b Maximum display: 9 999 999 impulses.
b Without reset.
b Metering data:
v minimum impulse time: 50 ms
v minimum time between 2 impulses: 50 ms.
b Storage temperature: -25 °C to +85 °C.
b Operating temperature: -10 °C to +70 °C.
b Connection: tunnel terminals for 2.5 mm2 cable.
Catalogue number
Type Width in mod.
of 9 mm
Cat. no.
iCI 415443
Connection
DB114271
iCL.eps
iCI impulse counter
load
load
Panel instruments
33
PLSED309005EN
Dimensions
Ammeters, voltmeters, selector switches,
impulse counter, hour counters
Panel instruments
Analogue ammeters and voltmeters iAMP, iVLT
DB103473
Digital ammeters, voltmeter and frequency meter iAMP, iVLT
DB103474
iCMA and iCMV selector switches
DB103475
72 x 72 analogue ammeters and voltmeter
DB103476
96 x 96 analogue ammeters and voltmeter
DB103481
Protection cover
Capot de protection
Terminal
M4
Protection cover
Capot de protection
Terminal
M4
34 PLSED309005EN
Dimensions (cont.)
Ammeters, voltmeters, selector switches,
impulse counter, hour counters
Panel instruments
48 x 48 CMA and CMV selector switches
DB103477
iCI impulse counter and iCH hour counter
DB103479
48 x 48 CH hour counters
DB109825
3.2 (or 4.8)
24.1 (or 33)
22.3 (or 30.5)
(with adapter)
35
PLSED309005EN
Acti 9 iEM2000 Series
Energy Meters
Basic energy meters
The Acti 9 iEM2000 and iEM2100 Series Energy Meters offer a cost-attractive,
competitive range of single-phase DIN rail-mounted energy meters ideal for
sub-billing and cost allocation applications.
Combined with communication systems, like Smart Link, the Acti 9 iEM2000 Series
makes it easy to integrate electrical distribution measurements into customer’s energy
management systems. It’s the right energy meter at the right price for the right job.
Two versions are available: 40 A direct measure (iEM2000 models), and 63 A direct
measure (iEM2100 models). Within each set of models, there are different versions
to match the specic application, from basic to more advanced:
biEM2000T single-phase kilowatt-hour meter without display, with kWh pulse output.
biEM2000 single-phase kilowatt-hour meter, MID certied.
biEM2010 single-phase kilowatt-hour meter, kWh pulse output, MID certied.
biEM2100 single-phase kilowatt-hour meter.
biEM2105 single-phase kilowatt-hour meter, with partial counter, kWh pulse output.
biEM2110 single-phase kilowatt-hour meter, multi-tariffs with partial counter and
current, voltage, power measurement, pulse outputs, MID certied.
biEM2135 single-phase kilowatt-hour meter, multi-tariffs with partial counter and
current, voltage, power measurement. M-Bus communication, MID certied.
biEM2150 single-phase kilowatt-hour meter with partial counter and current,
voltage, power measurement. Modbus communication.
biEM2155 single-phase kilowatt-hour meter, multi-tariffs with partial counter and
current and voltage, power measurement. Modbus communication, MID certied.
Innovative design makes the meters smart and simple:
bEasy to install for panel builders.
bEasy to commission for contractors and installers.
bEasy to operate for end users.
Applications
bCost management applications.
bBill verication.
bSub-billing and cost allocation, including two tariffs.
Network management applications.
bBasic electrical parameters like current, voltage and power.
Market segments
bBuildings & Industry.
bData centres and networks.
bInfrastructure (airports, road tunnels, telecom).
Characteristics
bSelf-powered meters.
bCompliance with IEC 62053-21, IEC 62053-23, EN50470-3.
bCompact, 1 or 2 module width.
bOnboard Modbus or M-Bus communication.
bAnti-tamper security features ensure the integrity of your data.
bSingle phase circuit plus neutral.
bIP40 front panel and IP20 casing.
bOperating frequency 50/60 Hz.
bMID compliant (selected models) providing certied accuracy and data security.
PB110836
iEM2000T iEM2010
PB115002_1
PB115001
iEM2105 iEM2155
Meter model and description Current measurement Part number
iEM2000T basic energy meter, without display Direct connected to 40 A A9MEM2000T
iEM2000 basic energy meter, MID certied Direct connected to 40 A A9MEM2000
iEM2010 energy meter, kWh pulse output, MID certied Direct connected to 40 A A9MEM2010
iEM2100 basic energy meter Direct connected to 63 A A9MEM2100
iEM2105 energy meter, kWh pulse output with partial meter Direct connected to 63 A A9MEM2105
iEM2110 energy meter, kWh and kvarh pulse outputs with two tariffs, four quadrant energy
measurement, MID certied
Direct connected to 63 A A9MEM2110
iEM2135 energy meter, M-Bus communication, four quadrant energy measurement, two
tariffs, MID certied
Direct connected to 63 A A9MEM2135
iEM2150 energy meter, Modbus communication, four quadrant energy measurement Direct connected to 63 A A9MEM2150
iEM2155 energy meter, Modbus communication, four quadrant energy measurement, two
tariffs, MID certied
Direct connected to 63 A A9MEM2155
36 PLSED309005EN
Acti 9 iEM2000 Series
Energy Meters
Basic energy meters
iEM2000 & iEM2100 technical specications
FUNCTION GUIDE iEM2000T iEM2000 iEM2010 iEM2100 iEM2105 iEM2110 iEM2135 iEM2150 iEM2155
Direct connection Up to 40 A Up to 63 A
Width 1 x 18 mm module (18 mm) 2 x 18 mm modules (36 mm)
MID compliance n n n n n
Multi-tariff 2 tariffs 2 tariffs 2 tariffs
Four quadrant energy
measurement
nnnn
Communication M-Bus Modbus
Digital input (tariff
switching)
1 1 1
Pulse output for kWh/
kvarh
1 1 1 2
Pulse output operation 100 pulses / kWh (120 ms long) 1 pulse /
kWh (200
ms long)
1 to 1000
pulses /
kWh or
kvarh (30
to 100 ms
long)
Accuracy class: Active
Energy
Class 1
IEC 62053-21
Class 1
IEC 62053-21
Class B
EN50470-3
Class 1
IEC 62053-21
Class B
EN50470-3
Class 1
IEC 62053-21
Class 1
IEC 62053-21
Class 1
IEC 62053-21
Class B
EN50470-3
Class 1
IEC 62053-21
Class B
EN50470-3
Class 1
IEC 62053-21
Class 1
IEC 62053-21
Class B
EN50470-3
Accuracy class: Reac-
tive Energy
Class 2 (according to IEC62053-23)
Display capacity 999999.9 kWh 99999 kWh or 999.99
MWh
999999.99 kWh
Voltage range (L-N) 184 to 276 Vac 184 to 276 Vac 92 to 276 Vac
Meter constant LED 3200 ashes per kWh 1000 ashes per kWh
Wiring capacity (Top) 4 mm26 mm24 mm2
Wiring capacity
(Bottom)
10 mm216 mm232 mm2
Consumption <10 VA 2.5 VA 3 VA
Temperature -10°C to +55°C -25°C to +55°C
kWh nnnnnnnnn
kVARh nnnn
Active power nnnn
Reactive power nnnn
Power Factor nnnn
Current and voltage nnnn
Frequency nnnn
37
PLSED309005EN
iEM2000 & iEM2100 technical specications
FUNCTION GUIDE iEM2000T iEM2000 iEM2010 iEM2100 iEM2105 iEM2110 iEM2135 iEM2150 iEM2155
Direct connection Up to 40 A Up to 63 A
Width 1 x 18 mm module (18 mm) 2 x 18 mm modules (36 mm)
MID compliance n n n n n
Multi-tariff 2 tariffs 2 tariffs 2 tariffs
Four quadrant energy
measurement
nnnn
Communication M-Bus Modbus
Digital input (tariff
switching)
1 1 1
Pulse output for kWh/
kvarh
1 1 1 2
Pulse output operation 100 pulses / kWh (120 ms long) 1 pulse /
kWh (200
ms long)
1 to 1000
pulses /
kWh or
kvarh (30
to 100 ms
long)
Accuracy class: Active
Energy
Class 1
IEC 62053-21
Class 1
IEC 62053-21
Class B
EN50470-3
Class 1
IEC 62053-21
Class B
EN50470-3
Class 1
IEC 62053-21
Class 1
IEC 62053-21
Class 1
IEC 62053-21
Class B
EN50470-3
Class 1
IEC 62053-21
Class B
EN50470-3
Class 1
IEC 62053-21
Class 1
IEC 62053-21
Class B
EN50470-3
Accuracy class: Reac-
tive Energy
Class 2 (according to IEC62053-23)
Display capacity 999999.9 kWh 99999 kWh or 999.99
MWh
999999.99 kWh
Voltage range (L-N) 184 to 276 Vac 184 to 276 Vac 92 to 276 Vac
Meter constant LED 3200 ashes per kWh 1000 ashes per kWh
Wiring capacity (Top) 4 mm26 mm24 mm2
Wiring capacity
(Bottom)
10 mm216 mm232 mm2
Consumption <10 VA 2.5 VA 3 VA
Temperature -10°C to +55°C -25°C to +55°C
kWh nnnnnnnnn
kVARh nnnn
Active power nnnn
Reactive power nnnn
Power Factor nnnn
Current and voltage nnnn
Frequency nnnn
Acti 9 iEM2000 Series
Energy Meters
iEM2000 dimensions
DB116734
iEM2100/iEM2105 dimensions
DB103483
iEM2110/iEM2135/iEM2150/iEM2155 dimensions
PB115003
NOTE: See the appropriate product Installation Guide for complete instructions.
Basic energy meters
38 PLSED309005EN
Acti 9 iEM3000 Series Energy Meters
Functions and characteristics
Basic energy meters
PB108410
The Acti 9 iEM3000 Energy Meter Series offers a cost-attractive, competitive range of
DIN rail-mounted energy meters ideal for sub-billing and cost allocation applications.
Combined with communication systems, like Smart Link, the Acti 9 iEM3000 Series
makes it easy to integrate electrical distribution measurements into customer’s facility
management systems. It’s the right energy meter at the right price for the right job.
Three versions are available: 63A direct measure (iEM3100 models), current
transformers associated meter (iEM3200 models), and 125A direct measure
(iEM3300 models). For each range, eight versions are available (seven for the
iEM3300) to satisfy basic to advanced applications:
b iEM3100/iEM3200/iEM3300: kWh meter with partial counter
b iEM3110/iEM3210/iEM3310: kWh meter with partial counter and pulse output.
MID certied.
b iEM3115/iEM3215: multi-tariff meter controlled by digital input or internal clock,
MID certied.
b iEM3135/iEM3235/iEM3335: energy meter, four quadrant, multi-tariffs with partial
counter and current, voltage, power measurement. M-Bus communication, digital I/O
and MID certied.
b iEM3150/iEM3250/iEM3350: kWh meter with partial counter and current, voltage,
power measurement. Modbus communication.
b iEM3155/iEM3255/iEM3355: energy meter, four quadrant, multi-tariffs with partial
counter and current, voltage, power measurement. Modbus communication, digital
I/O, MID certied.
b iEM3165/iEM3265/iEM3365: energy meter, four quadrant, multi-tariffs with partial
counter and current, voltage, power measurement. BACnet communication, digital
I/O and MID certied.
b iEM3175/iEM3275/iEM3375: energy meter, four quadrant, multi-tariffs with partial
counter and current, voltage, power measurement. LON communication, digital
input and MID certied.
Innovative design makes the meters smart and simple:
bEasy to install for panel builders
bEasy to commission for contractors and installers
bEasy to operate for end users
Applications
Cost management applications
b�Bill verication
bSub-billing, including WAGES view (four user-dened tariffs)
bCost allocation, including WAGES view
Network management applications
bBasic electrical parameters like current, voltage and power
bOnboard overload alarm to avoid circuit overload and trip
bEasy integration with PLC systems by input/output interface
bMarket segments
bBuildings & Industry
bData centres and networks
bInfrastructure (airports, road tunnels, telecom)
bCharacteristics
b�Self-powered meters
b�Chain measurement (meters + CTs) accuracy class 1
b�Compliance with IEC 61557-12, IEC 62053-21/22, IEC 62053-23, EN50470-3
b Compact, 5 module width
b Graphical display for easy viewing
b�Onboard Modbus, LON, M-Bus or BACnet communication
b�Easy wiring (without CTs) Acti 9 iEM3100 and iEM3300 models
b�Double xation on DIN rail (horizontal or vertical)
b�Anti-tamper security features ensure the integrity of your data
b�MID compliant (selected models) providing certied accuracy and data security
Acti 9 iEM3100/3200 energy meter
PB113590
Acti 9 iEM3300 energy meter
Front Panel Display and Buttons
A Measurement
B Ea /Er = active / reactive energy (if
available)
C Value
D Active tariff (if applicable)
E Scroll through the available screens
F View more screens related to the
measurement category (if available)
G Go back to previous screen
H Date and time (if applicable)
I Unit
J Icon indicating date / time not set
PB105323
39
PLSED309005EN
Function guide iEM3100
iEM3200
iEM3300
iEM3110
iEM3210
iEM3310
iEM3115
iEM3215
iEM3135
iEM3235
iEM3335
iEM3150
iEM3250
iEM3350
iEM3155
iEM3255
iEM3355
iEM3165
iEM3265
iEM3365
iEM3175
iEM3275
iEM3375
Width (18 mm module, DIN rail mounting) 5 / 5 / 7 5 / 5 / 7 5 / 5 5 / 5 / 7 5 / 5 / 7 5 / 5 / 7 5 / 5 / 7 5 / 5 / 7
Direct measurement (up to 63A or 125A) 63A / / 125A 63A / / 125A 63A / − 63A / / 125A 63A / / 125A 63A / / 125A 63A / / 125A 63A / / 125A
Measurement inputs through CTs (1A, 5A) / ■ / − / / / − / ■ / − / / − − / ■ / − / ■ / − − / ■ / −
Measurement inputs through VTs / / / / / ■ / − / ■ / − / ■ / −
Active Energy measurements class
(Total & partial kWh)
1 / 0.5S / 1 1 / 0.5S / 1 1 / 0.5S 1 / 0.5S / 1 1 / 0.5S / 1 1 / 0.5S / 1 1 / 0.5S / 1 1 / 0.5S / 1
Four Quadrant Energy measurements b b b b
Electrical measurements (I, V, P, ...) b b b b b
Multi-tariff (internal clock) 4 4 4 4 4
Multi-tariff (external control) 4 2 2 2 2
Measurement display (number of lines) 3 3 3 3 3 3 3 3
Digital inputs Programmable
(Tariff control or
WAGES input)
1 1 1 1
Tariff control only 2
Digital ouputs Programmable (kWh
pulse or kW alarm)
1 1 1
kWh pulse only 1
kW overload alarm 1 1 1
M-Bus protocol b
Modbus protocol b b
BACnet protocol b
LON b
MID (legal metrology certication) b b b b b b
PB108423
Connectivity advantages
Programmable digital input External tariff control signal (4 tariffs)
Remote Reset partial counter
External status, e.g. breaker status
Collect WAGES pulses
Programmable digital output kWh overload alarm (iEM3135, iEM3155, iEM3165
iEM3235, iEM3255, iEM3265, EM3335, iEM3355, iEM3365)
kWh pulses
Graphic LCD display Scroll energies
Current, voltage, power, frequency, power factor
Communication Serial communication options are available with M-Bus,
Modbus, BACnet or LON protocols
Standards
Standards IEC 61557-12, IEC 61036, IEC 61010, UL61010-1, IEC
62053-21/22 Class 1 and Class 0.5S, IEC 62053-23
Acti 9 iEM3100 models direct connected (63 A) Direct
connected up to 63 A
Multi-tariff capability
The Acti 9 iEM3000 Series allows arrangement of kWh consumption in four different
registers. This can be controlled by:
b Digital Inputs. Signal can be provided by PLC or utilities
b Internal clock programmable by HMI
b Through communication
This function allows users to:
b Make tenant metering for dual source applications to differentiate backup source or
utility source
b Understand well the consumption during working time and non working time, and
between working days and weekends
b Follow up feeders consumption in line with utility tariff rates
Acti 9 iEM3200 models (1 A / 5 A CT connected)
PB108424
Acti 9 iEM3000 Series Energy Meters
Functions and characteristics
Basic energy meters
40 PLSED309005EN
Acti 9 iEM3000 Series Energy Meters
Functions and characteristics
Basic energy meters
Specication guide iEM3100/iEM3300 Models
iEM3100
iEM3300
iEM3110
iEM3310
iEM3115 iEM3135
iEM3335
iEM3150
iEM3350
iEM3155
iEM3355
iEM3165
iEM3365
iEM3175
iEM3375
Current (max.) Direct connected
(iEM31xx)
63A for iEM3100 models, 125A for iEM3300 models
Meter constant LED 500/kWh
Pulse output Up to
1000p/kWh
Up to
1000p/kWh
Up to
1000p/kWh
Multi-tariff 4 tariffs 4 tariffs 4 tariffs
Communication M-bus Modbus Modbus BACnet LON
DI/DO 0/1 2/0 1/1 1/1 1/1 1/0
MID (EN50470-3) b b b b b
Network 1P+N, 3P, 3P+N
Accuracy class Class 1 (IEC 62053-21 and IEC61557-12) Class B (EN50470-3)
Wiring capacity 16 mm² for iEM3100 models, 50 mm2 for iEM3300 models
Display max. LCD 99999999.9kWh
Voltage (L-L) 3 x 100/173 V AC to 3 x 277/480 V AC (50/60 Hz)
IP protection IP40 front panel and IP20 casing
Temperature -25°C to 55°C (K55)
Product size 5 x 18 mm for iEM3100 models, 8 x 18 mm for iEM3300 models
Overvoltage and measurement Category III, Degree of pollution 2
kWh bbbbbbbb
kVARh b b b b
Active power bbbbb
Reactive power b b b b
Currents and voltages bbbbb
Overload alarm b b b b
Hour counter b b b b
Specication guide iEM3200 Models
iEM3200 iEM3210 iEM3215 iEM3235 iEM3250 iEM3255 iEM3265 iEM3275
1 A / 5 A CTs (max current) 6 A
Meter constant LED 5000/kWh
Pulse output frequency Up to
500p/kWh
Up to
500p/kWh
Up to 500p/kWh
Multi-tariff 4 tariff 4 tariffs 4 tariffs
Communication M-bus Modbus Modbus BACnet LON
DI/DO 0/1 2/0 1/1 1/1 1/1 1/0
MID (EN50470-3) bbb bbb
Network 1P+N, 3P, 3P+N
support CTs
1P+N, 3P, 3P+N
support CTs & VTs
Accuracy class Class 0.5S (IEC 62053-22 and IEC61557-12) Class C (EN50470-3)(1)
Wiring capacity 6 mm² for currents and 4 mm² for voltages
Display max. LCD 99999999.9kWh or 99999999.9MWh
Voltage (L-L) 3 x 100/173 V AC to 3 x 277/480 V AC (50/60 Hz)
IP protection IP40 front panel and IP20 casing
Temperature -25°C to 55°C (K55)
Product size 5 steps of 18 mm
Overvoltage & measurement Category III, Degree of pollution 2
kWh bbbbbbbb
kVARh b b b b
Active power bbbbb
Reactive power b b b b
Currents and voltages bbbbb
Overload alarm b b b b
Hour counter b b b b
(1) For 1 A CTs Class 1 (IEC6253-21 and IEC61557-12 Class B (EN50470-3)
41
PLSED309005EN
iEM3000/iEM3200 series dimensions
PB113600
Acti 9 iEM3100/iEM3200 Series front aps open and closed
PB105305
PB105306
Acti 9 iEM3000 Series parts
1. Digital inputs for tariff control (iEM3115 / iEM3215)
2. Display for measurement and conguration
3. Pulse out for remote transfer (iEM3110 / iEM3210)
4. Cancellation
5. Conrmation
6. Selection
7. Flashing yellow meter indicator to check accuracy
8. Green indicator: on/off, error
PB105313
PB1053241
Acti 9 iEM3000 Series Energy Meters
Dimensions and connection
Basic energy meters
iEM3300 series dimensions
PB113599
ON
OK ESC
Reset
Config
L3’ L3 L2 L1’ L1L1
L2’
N’N
200 /kWh
S0+S0-
126
4.96
69.3
2.73
93.8
3.7
45
1.77
63.8
2.51
103.2
4.06
ON
OK ESC
Reset
Config
L3’ L3 L2 L1’ L1L1
L2’
N’N
200 /kWh
S0+S0-
126
4.96
69.3
2.73
93.8
3.7
45
1.77
63.8
2.51
103.2
4.06
Acti 9 iEM3000 Series parts
1. Digital inputs for tariff control (iEM3115 / iEM3215)
2. Display for measurement and conguration
3. Pulse out for remote transfer (iEM3110 / iEM3210)
4. Cancellation
5. Conrmation
6. Selection
7. Flashing yellow meter indicator to check accuracy
8. Green indicator: on/off, error
42 PLSED309005EN
Meter model and description Current measurement Ref. no.
iEM3100 basic energy meter Direct connected 63 A A9MEM3100
iEM3110 energy meter with pulse output Direct connected 63 A A9MEM3110
iEM3115 multi-tariff energy meter Direct connected 63 A A9MEM3115
iEM3135 advanced multi-tariff energy meter &
electrical parameter plus M-Bus comm port
Direct connected 63 A A9MEM3135
iEM3150 energy meter & electrical parameter
plus Modbus RS485 comm port
Direct connected 63 A A9MEM3150
iEM3155 advanced multi-tariff energy meter &
electrical parameter plus Modbus RS485 comm
port
Direct connected 63 A A9MEM3155
iEM3165 advanced multi-tariff energy meter &
electrical parameter plus BACnet MS/TP comm
port
Direct connected 63 A A9MEM3165
iEM3175 advanced multi-tariff energy meter &
electrical parameter plus LON TP/FT-10 comm
port
Direct connected 63 A A9MEM3175
iEM3200 basic energy meter Transformer connected 5 A A9MEM3200
iEM3210 energy meter with pulse output Transformer connected 5 A A9MEM3210
iEM3215 multi-tariff energy meter Transformer connected 5 A A9MEM3215
iEM3235 advanced multi-tariff energy meter &
electrical parameter plus M-Bus comm port
Transformer connected 5 A A9MEM3235
iEM3250 energy meter & electrical parameter
plus Modbus RS485 comm port
Transformer connected 5 A A9MEM3250
iEM3255 advanced multi-tariff energy meter &
electrical parameter plus Modbus RS485 comm
port
Transformer connected 5 A A9MEM3255
iEM3265 advanced multi-tariff energy meter &
electrical parameter plus BACnet MS/TP comm port
Transformer connected 5 A A9MEM3265
iEM3275 advanced multi-tariff energy meter &
electrical parameter plus LON TP/FT-10 comm port
Transformer connected 5 A A9MEM3275
iEM3300 basic energy meter Direct connected 125 A A9MEM3300
iEM3310 energy meter with pulse output Direct connected 125 A A9MEM3310
iEM3335 advanced multi-tariff energy meter &
electrical parameter plus M-Bus comm port
Direct connected 125 A A9MEM3335
iEM3350 energy meter & electrical parameter
plus Modbus RS485 comm port
Direct connected 125 A A9MEM3350
iEM3355 advanced multi-tariff energy meter &
electrical parameter plus Modbus RS485 comm port
Direct connected 125 A A9MEM3355
iEM3365 advanced multi-tariff energy meter &
electrical parameter plus BACnet MS/TP comm port
Direct connected 125 A A9MEM3365
iEM3375 advanced multi-tariff energy meter &
electrical parameter plus LON TP/FT-10 comm port
Direct connected 125 A A9MEM3375
Acti 9 iEM3000 Series Energy Meters
Commercial reference numbers
Basic energy meters
See your Schneider Electric representative for complete ordering information.
43
PLSED309005EN
Meter model and description Current measurement Ref. no.
iEM3100 basic energy meter Direct connected 63 A A9MEM3100
iEM3110 energy meter with pulse output Direct connected 63 A A9MEM3110
iEM3115 multi-tariff energy meter Direct connected 63 A A9MEM3115
iEM3135 advanced multi-tariff energy meter &
electrical parameter plus M-Bus comm port
Direct connected 63 A A9MEM3135
iEM3150 energy meter & electrical parameter
plus Modbus RS485 comm port
Direct connected 63 A A9MEM3150
iEM3155 advanced multi-tariff energy meter &
electrical parameter plus Modbus RS485 comm
port
Direct connected 63 A A9MEM3155
iEM3165 advanced multi-tariff energy meter &
electrical parameter plus BACnet MS/TP comm
port
Direct connected 63 A A9MEM3165
iEM3175 advanced multi-tariff energy meter &
electrical parameter plus LON TP/FT-10 comm
port
Direct connected 63 A A9MEM3175
iEM3200 basic energy meter Transformer connected 5 A A9MEM3200
iEM3210 energy meter with pulse output Transformer connected 5 A A9MEM3210
iEM3215 multi-tariff energy meter Transformer connected 5 A A9MEM3215
iEM3235 advanced multi-tariff energy meter &
electrical parameter plus M-Bus comm port
Transformer connected 5 A A9MEM3235
iEM3250 energy meter & electrical parameter
plus Modbus RS485 comm port
Transformer connected 5 A A9MEM3250
iEM3255 advanced multi-tariff energy meter &
electrical parameter plus Modbus RS485 comm
port
Transformer connected 5 A A9MEM3255
iEM3265 advanced multi-tariff energy meter &
electrical parameter plus BACnet MS/TP comm port
Transformer connected 5 A A9MEM3265
iEM3275 advanced multi-tariff energy meter &
electrical parameter plus LON TP/FT-10 comm port
Transformer connected 5 A A9MEM3275
iEM3300 basic energy meter Direct connected 125 A A9MEM3300
iEM3310 energy meter with pulse output Direct connected 125 A A9MEM3310
iEM3335 advanced multi-tariff energy meter &
electrical parameter plus M-Bus comm port
Direct connected 125 A A9MEM3335
iEM3350 energy meter & electrical parameter
plus Modbus RS485 comm port
Direct connected 125 A A9MEM3350
iEM3355 advanced multi-tariff energy meter &
electrical parameter plus Modbus RS485 comm port
Direct connected 125 A A9MEM3355
iEM3365 advanced multi-tariff energy meter &
electrical parameter plus BACnet MS/TP comm port
Direct connected 125 A A9MEM3365
iEM3375 advanced multi-tariff energy meter &
electrical parameter plus LON TP/FT-10 comm port
Direct connected 125 A A9MEM3375
PowerLogic BCPM
Functions and characteristics
PE86281
PowerLogicTM BCPM A/B/C main board
The ideal solution for data centre managers, energy or facility managers, engineers and
operational executives who are responsible for delivering power to critical applications. In
corporate and hosted data centre facilities, this technology helps you plan and optimise
the critical power infrastructure to meet the demands of continuous availability.
The PowerLogic BCPM is a highly accurate, full-featured metering product designed for
the unique, multi-circuit and minimal space requirements of a high performance power
distribution unit (PDU) or remote power panel (RPP). It offers class 1 (1%) power and
energy system accuracy (including 50A or 100A CTs) on all branch channels.
The BCPM monitors up to 84 branch circuits with a single device and also monitors
the incoming power mains to provide information on a complete PDU. It also offers
multi-phase measurement totals with exible support for any conguration of
multi-phase breakers. Full alarming capabilities ensure that potential issues are dealt
with before they become problems.
Unlike products designed for specic hardware, the exible BCPM will t any PDU or
RPP design and supports both new and retrot installations. It has exceptional
dynamic range and accuracy, and optional feature sets to meet the energy
challenges of mission critical data centres.
Applications
Revenue Grade sub-billing.
Data Centre load monitoring and alarming
Comprehensive monitoring of lighting control panels
Maximise uptime and avoid outages.
Optimise existing infrastructure.
Effectively plan future infrastructure needs.
Improve power distribution efciency.
Track usage and allocate energy costs.
Main characteristics
Monitor up to 84 branch circuits with a single BCPM.
Ideal for installation in both new PDUs and retrot projects:
bNew installations: BCPM with solid core CTs monitors up to 84 branch circuits
using 2 or 4 CT strips. Solid core CTs are rated to 100 A CTs and are mounted on
strips to simplify installation. CT strips are available with 12, 8 or 21 CTs per strip on
18 mm spacings. 21 CT strips with 3/4” or 1” spacings are also available.
bRetrot projects: BCPMSC with split core CTs is ideal for retrots. Any number of split
core CTs, up to 84 maximum, can be installed with a single BCPM. Three sizes of CT are
supported (50 A, 100 A, and 200 A) and all three CT sizes can be used on a single
BCPM. Adapter boards with terminals for split-core CTs can be mounted using DIN-rail,
Snaptrack or on a common mounting plate with the main board (42 ch Y63 models only).
Class 1.0 system accuracy for Revenue Grade measurements
Branch Power and Energy measurements fully meet ANSI and IEC class 1 accuracy
requirements with 50 or 100 Amp CTs included. No need to de-rate meter branch
accuracy to allow for CTs. Voltage and current measurement accuracy is 0.5% and
currents are measured down to 50mA. Easily differentiate between the ow of low
current and a trip where no current ows.
Designed to t any PDU or RPP design
Lowers your total installation costs as well as the cost per meter point by supporting
both new and retrot installations.
New models with integrated Ethernet offer broad protocol support
All models integrate easily into existing networks using Modbus RTU communications
over an RS-485 serial link. BCPME and BCPMSCE models offer integrated Ethernet
and add support for Modbus TCP, BACnet IP, BACnet MS/TP and SNMP. An optional
external gateway can be added to all other models to add the same capability.
Compatible with PowerLogic power monitoring software
Easily turn the large amount of data collected by the devices into useful decision-
making information.
Multi-circuit metering
PowerLogicTM BCPM split core 12mm, 18mm, 21mm, .75 in and 1 in
CTs strips
PB113644
Flexible Conguration capability
Set the ordering and orientation of CT strips, assign individual CT size and phases,
support for 1, 2, and 3-pole breakers in any conguration.
PowerLogicTM BCPME Measurement Unit”
PB113646PB113647PB113649 PB113645
PB113648
44 PLSED309005EN
PowerLogic BCPM
Functions and characteristics (cont.)
PE86167
PowerLogic BCPM
1 50-pin ribbon cable connectors (data acquisition board).
2 Auxiliary inputs.
3 Control (mains) power connection.
4 Control power fuse.
5 Alive LED.
6 Voltage taps.
7 Communications address DIP switches.
8 Communications settings DIP switch.
9 RS-485 2 connection.
10 RS-485 LEDs.
Selection guide BCPMA BCPMB BCPMC BCPME
General
Use on LV systems b b b b
Power and energy measurements
Mains b b -b
Branch circuits b- - b
Instantaneous rms values
Voltage, frequency b b -b
Current b b b b
Active power Total and per phase b b
(mains only)
-b
Power factor Total and per phase b b
(mains only)
-b
Energy values
Active energy b b
(mains only)
-b
Demand values
Total active power Present and max.
values
b b
(mains only)
-b
Power quality measurements
Detection of over-voltage/under-voltage b b -b
Alarming
Alarms b b b b
Power supply
AC version
90-277 V ac 90-277 V ac 90-277 V ac 100-277 V ac
Communication
RS 485 port b b b b
Modbus protocol b b b b
Ethernet Port 1* 1* 1* b
Modbus RTU protocol 1* 1* 1* b
BACnet IP protocol 1* 1* 1* b
BACnet MS/TP protocol 1* 1* 1* b
SNMP protocol 1* 1* 1* b
Multi-circuit metering
*1 Add E8951 Gateway
PowerLogic BCPM specications
Electrical characteristics
Type of measurement
Accuracy Power/energy 1% system accuracy (including 50A or 100A
branch CTs)
Voltage ±0.5% of reading
Current ±0.5% of reading
Minimum “ON” current 50mA
Sampling rate Points per cycle 2560 Hz
Data update rate 1.8 seconds (Modbus), 14 seconds (BACnet) 20
sec (SNMP)
Input-voltage
characteristics
Measured voltage 150 – 480 V ac L-L (1)
90 – 277 V ac L-N (1)
Measurement range 150 – 480 V ac L-L (1)
90 – 277 V ac L-N (1)
Power supply AC 100 – 277 V ac (50/60 Hz)
Auxiliary CT Current Input Range 0-0.333V; CTs must be rated for use with Class 1
voltage inputs
Mechanical characteristics
Weight 1.5 kg
Dimensions A/B/C model Circuit
board
288 x 146 mm
E model housing (w/
brackets on long sides)
253 mm W x 307 mm H x 71 mm D
E model housing (w/
brackets on short ends)
210 mm W x 353 mm H x 71 mm D
45
PLSED309005EN
PowerLogic BCPM
Functions and characteristics (cont.)
Multi-circuit metering
PowerLogic BCPM specications (cont’d)
Environmental conditions
Operating temperature 0 to 60ºC
Storage temperature -40ºC to 70ºC
Installation category CAT III, pollution degree 2
Safety
Europe IEC 61010
U.S. and Canada UL 508 Open type device
Communication
RS 485 (A/B/C models) Baud rate: DIP-switch selectable 9600, 19200, 38400
DIP-switch selectable 2-wire or 4-wire RS-485. Parity
selectable: Even, Odd or None.
RS 485 (E Models) Baud rate: congured via Web-server. Baud selectable:
9600, 19200, 38400. Parity selectable: Even, Odd or
None. 2-wire RS-485.
Ethernet (E models) 10/100 Mbit Ethernet. RJ-45 connection. Static IP or
DHCP.
Protocols Modbus RTU on all models, BCPME models also support
Modbus TCP, SNMP, BACnet IP & BACnet MS/TP
Firmware characteristics
Detection of over-voltage/
under-voltage
User-dened alarm thresholds for over-voltage and
under-voltage detection
Alarms
Four alarm levels: high-high, high, low and low-low (users
dene the setpoints for each). Each alarm has a latching
status to alert the operator that an alarm has previously
occurred. High and Low alarms have instantaneous status
to let the operator know if the alarm state is still occurring.
Firmware update Update via Modbus
(1) Feature sets ‘A , ‘B’ and ‘E only.
1/3 V low-voltage CT (LVCT) for Mains - specications
Electrical characteristics
Accuracy 1% from 10% to 100% of rated
current(LVCT0xxxx0S/1S/2S/3S/4S [split-core])
0.5% from 5% to 100% of rated current
(LVCT2xxxx0S/2S/3S [solid-core])
Frequency range 50/60 Hz
Leads 18 AWG, 600 V ac, 1.8m standard length
Max. voltage L-N sensed conductor 300 V ac (LVCT0xxxx0S)
600 V ac (LVCT0xxxx1S/2S/3S/4S, LVCT2xxxxxS)
Environmental conditions
Operating temperature 0ºC to 70ºC (LVCT0xxxx0S/1S)
-15ºC to 60ºC (LVCT0xxxx2S/3S/4S less than 2400A)
-15ºC to 60ºC (LVCT02404S [2400A])
-40ºC to 85ºC (LVCT2xxxx0S/2S/3S [solid-core])
Storage temperature -40ºC to 105ºC (LVCT0xxxx0S/1S)
-40ºC to 70ºC (LVCT0xxxx2S/3S/4S)
-50ºC to 105ºC (LVCT2xxxx0S/2S/3S [solid-core])
Humidity range 0 to 95% non-condensing
PowerLogic BCPM specications
Electrical characteristics
Type of measurement
Accuracy Power/energy 1% system accuracy (including 50A or 100A
branch CTs)
Voltage ±0.5% of reading
Current ±0.5% of reading
Minimum “ON” current 50mA
Sampling rate Points per cycle 2560 Hz
Data update rate 1.8 seconds (Modbus), 14 seconds (BACnet) 20
sec (SNMP)
Input-voltage
characteristics
Measured voltage 150 – 480 V ac L-L (1)
90 – 277 V ac L-N (1)
Measurement range 150 – 480 V ac L-L (1)
90 – 277 V ac L-N (1)
Power supply AC 100 – 277 V ac (50/60 Hz)
Auxiliary CT Current Input Range 0-0.333V; CTs must be rated for use with Class 1
voltage inputs
Mechanical characteristics
Weight 1.5 kg
Dimensions A/B/C model Circuit
board
288 x 146 mm
E model housing (w/
brackets on long sides)
253 mm W x 307 mm H x 71 mm D
E model housing (w/
brackets on short ends)
210 mm W x 353 mm H x 71 mm D
46 PLSED309005EN
PowerLogic BCPM
Functions and characteristics (cont.)
Multi-circuit metering
BCPM part numbers
BCPM with solid core CTs
Item Code Description
1 Model BCPM BCPM with solid core CTs. Highly accurate meter
that monitors branch circuits and the incoming
power mains and includes full alarming
capabilities
Example BCPM with solid core CTs part number. 2Feature set AAdvanced - Monitors power & energy per circuit &
mains, Modbus RTU only (add E8951 for other
protocols), Meter Main Board comes on an
aluminum mounting plate
1 Model.
2 Feature set.
3 CT spacing (solid-core models only)
4 Number of circuits.
5 Brand.
BIntermediate - Monitors current per circuit, power
and energy per mains, Modbus RTU only (add
E8951 for other protocols), Meter Main Board
comes on an aluminum mounting plate
CBasic - Monitors current only per circuit & mains,
Modbus RTU only (add E8951 for other protocols),
Meter Main Board comes on an aluminum
mounting plate
EAdvanced, with Ethernet - Monitors power &
energy per circuit & mains, Meter Main Board is
enclosed in a metal housing
3CT spacing 03/4” (19 mm) CT spacing
11” (26 mm) CT spacing
218 mm CT spacing
4Number of circuits 24 24 circuits, (2) 18-CT strips (18 mm spacing only)
36 36 circuits, (2) 18-CT strips (18 mm spacing only)
42 42 circuits, (2) 21-CT strips
48 48 circuits, (4) 18-CT strips (18 mm spacing only)
72 72 circuits, (4) 18-CT strips (18 mm spacing only)
84 84 circuits, (4) 21-CT strips
5 Brand S Schneider Electric
PE86168PB113664PB113665
The PowerLogic BCPM uses .333 VAC output split-core
CTs for the auxiliary inputs. These CTs are ordered
separately from the BCPM.
* Quantity and style of CT strips and cables included
varies by model
47
PLSED309005EN
BCPM with split core CTs
Model BCPMSC BCPM with split core CTs. Highly accurate meter
that monitors branch circuits and the incoming
power mains and includes full alarming
capabilities
2Feature set AAdvanced - Monitors power and energy per circuit
and mains, Modbus RTU only (add E8951 for
other protocols), Meter Main Board comes on an
aluminum mounting plate
BIntermediate - Monitors current per circuit, power
and energy per mains, Modbus RTU only (add
E8951 for other protocols), Meter Main Board
comes on an aluminum mounting plate
CBasic - Monitors current only per circuit and mains,
Modbus RTU only (add E8951 for other
protocols), Meter Main Board comes on an
aluminum mounting plate
EAdvanced, with Ethernet - Monitors power &
energy per circuit & mains, Meter Main Board is
enclosed in a metal housing
4Number of circuits 142 circuits (no branch CTs or ribbon cables, order
separately)
284 circuits (no branch CTs or ribbon cables, order
separately)
Y63 42 circuits – main and adapter boards on single
mounting plate (no branch CTs or ribbon, order
separately)
30 30 split core CTs (50 A)
42 42 split core CTs (50 A)
60 60 split core CTs (50 A)
84 84 split core CTs (50 A)
5 Brand S Schneider Electric
PowerLogic BCPM
Functions and characteristics (cont.)
Multi-circuit metering
PB113735PB113666
1 Model.
2 Feature set.
3 Number of circuits.
4 Brand.
The BCPMSC models with 1, 2 or Y63 as the
number of circuits DO NOT INCLUDE ANY branch
CTs or ribbon cables (they include only the Main
board and adapater board assemblies) . These
models are provided to allow users to order a
specic combination of CT quantities, CT sizes, CT
lead lengths and ribbon cable styles and lengths.
The CTs and cables must be ordered separately.
Models with more than 2 as the number of circuits
include 50A branch CTs with 2 meter leads and
1.8M round ribbon cables.
The PowerLogic BCPMSC uses .333 VAC output
split-core CTs for the auxiliary inputs. These CTs are
ordered separately from the BCPM.
* Quantity of CT and cables included varies by model
Example BCPMSC with split core CTs part number.
PB113730
48 PLSED309005EN
PowerLogic BCPM
Functions and characteristics (cont.)
Multi-circuit metering
PE86284
PB113650PB113651
Flat ribbon cable
Round ribbon cable
BCPM part numbers for solid and split core CTs (contd.)
BCPM with split core CTs
Part number Description
BCPMA042S 42-circuit solid-core power & energy meter, 100A CTs (2 strips), ¾” spacing
BCPMA084S 84-circuit solid-core power & energy meter, 100A CTs (4 strips), ¾”spacing
BCPMA142S 42-circuit solid-core power & energy meter, 100A CTs (2 strips), 1” spacing
BCPMA184S 84-circuit solid-core power & energy meter, 100A CTs (4 strips), 1” mm spacing
BCPMA224S 24-circuit solid-core power & energy meter, 100A CTs (2 strips), 18mm spacing
BCPMA236S 36-circuit solid-core power & energy meter, 100A CTs (2 strips), 18mm spacing
BCPMA242S 42-circuit solid-core power & energy meter, 100A CTs (2 strips), 18mm spacing
BCPMA248S 48-circuit solid-core power & energy meter, 100A CTs (4 strips), 18mm spacing
BCPMA272S 72-circuit solid-core power & energy meter, 100A CTs (4 strips), 18mm spacing
BCPMA284S 84-circuit solid-core power & energy meter, 100A CTs (4 strips), 18mm spacing
BCPMB042S 42-circuit solid-core branch current, mains power meter, 100A CTs (2 strips), ¾”
spacing
BCPMB084S 84-circuit solid-core branch current, mains power meter, 100A CTs (4 strips), ¾”
spacing
BCPMB142S 42-circuit solid-core branch current, mains power meter, 100A CTs (2 strips), 1”
spacing
BCPMB184S 84-circuit solid-core branch current, mains power meter, 100A CTs (4 strips), 1”
spacing
BCPMB224S 24-circuit solid-core branch current, mains power meter, 100A CTs (2 strips),
18mm spacing
BCPMB236S 36-circuit solid-core branch current, mains power meter, 100A CTs (2 strips),
18mm spacing
BCPMB242S 42-circuit solid-core branch current, mains power meter, 100A CTs (2 strips),
18mm spacing
BCPMB248S 48-circuit solid-core branch current, mains power meter, 100A CTs (4 strips),
18mm spacing
BCPMB272S 72-circuit solid-core branch current, mains power meter, 100A CTs (4 strips),
18mm spacing
BCPMB284S 84-circuit solid-core branch current, mains power meter, 100A CTs (4 strips),
18mm spacing
BCPMC042S 42-circuit solid-core branch current meter, 100A CTs (2 strips), ¾” spacing
BCPMC084S 84-circuit solid-core branch current meter, 100A CTs (4 strips), ¾” spacing
BCPMC142S 42-circuit solid-core branch current meter, 100A CTs (2 strips), 1” spacing
BCPMC184S 84-circuit solid-core branch current meter, 100A CTs (4 strips), 1” spacing
BCPMC224S 24-circuit solid-core branch current meter, 100A CTs (2 strips), 18mm spacing
BCPMC236S 36-circuit solid-core branch current meter, 100A CTs (2 strips), 18mm spacing
BCPMC242S 42-circuit solid-core branch current meter, 100A CTs (2 strips), 18mm spacing
BCPMC248S 48-circuit solid-core branch current meter, 100A CTs (4 strips), 18mm spacing
BCPMC272S 72-circuit solid-core branch current meter, 100A CTs (4 strips), 18mm spacing
BCPMC284S 84-circuit solid-core branch current meter, 100A CTs (4 strips), 18mm spacing
BCPME042S 42-circuit solid-core power & energy meter w/Ethernet, 100A CTs (2 strips), ¾”
spacing
BCPME084S 84-circuit solid-core power & energy meter w/Ethernet, 100A CTs (4 strips),
¾”spacing
BCPME142S 42-circuit solid-core power & energy meter w/Ethernet, 100A CTs (2 strips), 1”
spacing
BCPME184S 84-circuit solid-core power & energy meter w/Ethernet, 100A CTs (4 strips), 1”
mm spacing
BCPME224S 24-circuit solid-core power & energy meter w/Ethernet, 100A CTs (2 strips),
18mm spacing
BCPME236S 36-circuit solid-core power & energy meter w/Ethernet, 100A CTs (2 strips),
18mm spacing
BCPME242S 42-circuit solid-core power & energy meter w/Ethernet, 100A CTs (2 strips),
18mm spacing
BCPME248S 48-circuit solid-core power & energy meter w/Ethernet, 100A CTs (4 strips),
18mm spacing
BCPME272S 72-circuit solid-core power & energy meter w/Ethernet, 100A CTs (4 strips),
18mm spacing
BCPME284S 84-circuit solid-core power & energy meter w/Ethernet, 100A CTs (4 strips),
18mm spacing
Cabling and connection
Flat ribbon cables are recommended for use
when the BCPM printed circuit board will be
mounted inside of the PDU that is being
monitored. Round ribbon cables are the
prefered choice when the ribbon cable will be
threaded through conduit.
BCPMSCxY63S 42-circuit split-core models come
with the main board, (2) adapter boards and
ribbon cables all mounted on a backplate, to
simplify installation.
49
PLSED309005EN
PowerLogic BCPM
Functions and characteristics (cont.)
Multi-circuit metering
PE86183
PB113658
PowerLogicTM LVCT0xxxxS Split-core Low-voltage (1/3V) CTs for Aux
inputs (Mains) are ideal for retrot applications
PowerLogicTM LVCT2xxxxS Low-voltage (1/3V) solid-core CTs for
Aux inputs (Mains) are ideal for panel builders (small, medium, large)
PB113652
PB113657
The PowerLogicTM BCPM uses .333 VAC output
split-core CTs for the auxiliary inputs. These
CTs are ordered separately from the BCPM.
BCPM with split core CTs (cont’d)
BCPMSCA1S 42-circuit split-core power and energy meter, CTs and cables sold separately
BCPMSCA2S 84-circuit split-core power and energy meter, CTs and cables sold separately
BCPMSCA30S 30-circuit split-core power and energy meter, (30) 50A CTs & (2) 4’ cables
BCPMSCA42S 42-circuit split-core power and energy meter, (42) 50A CTs & (2) 4’ cables
BCPMSCA60S 60-circuit split-core power and energy meter, (60) 50A CTs & (4) 4’ cables
BCPMSCAY63S 42-circuit split core power and energy meter, all boards on backplate, CTs and
cables sold separately
BCPMSCA84S 84-circuit split-core power and energy meter, with (84) 50A CTs & (4) 4’ cables
BCPMSCB1S 42-circuit split-core branch current, mains power meter, CTs and cables sold
separately
BCPMSCB2S 84-circuit split-core branch current, mains power meter, CTs and cables sold
separately
BCPMSCB30S 30-circuit split-core branch current, mains power meter, (30) 50A CTs & (2) 4’
cables
BCPMSCB42S 42-circuit split-core branch current, mains power meter, (42) 50A CTs & (2) 4’
cables
BCPMSCB60S 60-circuit split-core branch current, mains power meter, (60) 50A CTs & (4) 4’
cables
BCPMSCBY63S 42-circuit split-core branch current, mains, all boards on backplate, CTs and
cables sold separately
BCPMSCB84S 84-circuit split-core branch current, mains power meter, (84) 50A CTs & (4) 4’
cables
BCPMSCC1S 42-circuit split-core current meter, CTs and cables sold separately
BCPMSCC2S 84-circuit split-core current meter, CTs and cables sold separately
BCPMSCC30S 30-circuit split-core current meter, (30) 50A CTs & (2) 4’ cables
BCPMSCC42S 42 circuit split-core current meter, (42) 50A CTs & (2) 4’ cables
BCPMSCC60S 60-circuit split-core current meter, (60) 50A CTs & (4) 4’ cables
BCPMSCCY63S 42-circuit split-core current meter, all boards on backplate, CTs and cables sold
separately
BCPMSCC84S 84-circuit split-core current meter, (84) 50A CTs & (4) 4’ cables
BCPMSCE1S 42-circuit split-core power and energy meter w/Ethernet, CTs and cables sold
separately
BCPMSCE2S 84-circuit split-core power and energy meter w/Ethernet, CTs and cables sold
separately
BCPMSCE30S 30-circuit split-core power and energy meter w/Ethernet, (30) 50A CTs & (2) 4’
BCPMSCE42S 42-circuit split-core power and energy meter w/Ethernet, (42) 50A CTs & (2) 4’
cables
BCPMSCE60S 60-circuit split-core power and energy meter w/Ethernet, (60) 50A CTs & (4) 4’
cables
BCPMSCE84S 84-circuit split-core power and energy meter w/Ethernet, (84) 50A CTs & (4) 4’
cables
50 PLSED309005EN
PowerLogic BCPM
Functions and characteristics (cont.)
Multi-circuit metering
BCPM split core branch CTs and adapter boards
BCPMSCADPBS BCPM adapter boards, quantity 2, for split core BCPM
BCPMSCCT0 BCPM 50A split core CTs, Quantity 6, 1.8 m lead lengths
BCPMSCCT0R20 BCPM 50A split core CTs, quantity 6, 6 m lead lengths
BCPMSCCT1 BCPM 100A split core CTs, Quantity 6, 1.8 m lead lengths
BCPMSCCT1R20 BCPM 100A split core CTs, Quantity 6, 6 m lead lengths
BCPMSCCT3 BCPM 200A split core CTs, Quantity 1, 1.8 m lead lengths
BCPMSCCT3R20 BCPM 200A split core CTs, Quantity 1, 6 m lead lengths
Additional accessories for use with BCPM products
BCPMCOVERS BCPM circuit board cover
BCPMREPAIR CT repair kit for solid core BCPM (includes one CT)
H6803R-0100 Additional 100A split core CT for use with solid core repair kit
E8951 Modbus to BACnet protocol converter
CBL008 Flat Ribbon cable (quantity 1) for BCPM, length = 0.45 m
CBL016 Flat Ribbon cable (quantity 1) for BCPM, length = 1.2 m
CBL017 Flat Ribbon cable (quantity 1) for BCPM, length = 1.5 m
CBL018 Flat Ribbon cable (quantity 1) for BCPM, length = 1.8 m
CBL019 Flat Ribbon cable (quantity 1) for BCPM, length = 2.4 m
CBL020 Flat Ribbon cable (quantity 1) for BCPM, length = 3.0 m
CBL021 Flat Ribbon cable (quantity 1) for BCPM, length = 6.1 m
CBL022 Round Ribbon cable (quantity 1) for BCPM, length = 1.2 m
CBL023 Round Ribbon cable (quantity 1) for BCPM, length = 3 m
CBL024 Round Ribbon cable (quantity 1) for BCPM, length = 6.1 m
CBL031 Round Ribbon cable (quantity 1) for BCPM, length = 0.5 m
CBL033 Round Ribbon cable (quantity 1) for BCPM, length = 0.8 m
1/3 V low-voltage Split-Core CTs for Aux inputs (Mains)
Part number Amperage rating Inside dimensions
LVCT00050S 50A 10 mm x 11 mm
LVCT00101S 200A 16 mm x 20 mm
LVCT00202S 200A 32 mm x 32 mm
LVCT00102S 100A 30 mm x 31 mm
LVCT00202S 200A 30 mm x 31 mm
LVCT00302S 300A 30 mm x 31 mm
LVCT00403S 400A 62 mm x 73 mm
LVCT00603S 600A 62 mm x 73 mm
LVCT00803S 800A 62 mm x 73 mm
LVCT00804S 800A 62 mm x 139 mm
LVCT01004S 1000A 62 mm x 139 mm
LVCT01204S 1200A 62 mm x 139 mm
LVCT01604S 1600A 62 mm x 139 mm
LVCT02004S 2000A 62 mm x 139 mm
LVCT02404S 2400A 62 mm x 139 mm
1/3 V low-voltage Solid core CTs for Aux inputs (Mains)
Part number Amperage rating Inside dimensions
LVCT20050S 50A 10 mm
LVCT20100S 100A 10 mm
LVCT20202S 200A 25 mm
LVCT20403S 400A 31 mm
51
PLSED309005EN
Multi-circuit metering PowerLogic BCPM
Dimensions and connection
211 mm
146 mm
122 mm
184 mm
228 mm
PowerLogic BCPM dimensions
PB113661
PB113662
1.0”
(26 mm)
1.0”
(26 mm)
2.75”
(70 mm)
4.6”
(117 mm)
PE86286
PowerLogic BCPM adapter board (one board
per 21 split core branch CTs)
PE86169
52 PLSED309005EN
PowerLogic BCPM
Dimensions and connection
Multi-circuit metering
PB113660 PB113659
50A-200A Split-Core CT dimensions
Small form factor
100/200/300 Amp
A = 96 mm
B = 30 mm
C = 31 mm
D = 30 mm
E = 100 mm
F = 121 mm
Large form factor
800/1000/1200/
1600/2000/2400 Amp
A = 125 mm
B = 139 mm
C = 62 mm
D = 30 mm
E = 201 mm
F = 151 mm
Medium form factor
400/600/800 Amp
A = 125 mm
B = 73 mm
C = 62 mm
D = 30 mm
E = 132 mm
F = 151 mm
PB113663
1/3 V low-voltage CT form factor
Solid core CT dimensions
D
E
C
B
A
D
E
B
A
C
E31CT0 50 Amp
A = 1.0” (26 mm)
B = 0.5” (11 mm)
C = 0.4” (10 mm)
D = 0.9” (23 mm)
E = 1.6” (40 mm)
E31CT1 100 Amp
A = 1.5” (39 mm)
B = 0.8” (20 mm)
C = 0.7” (16 mm)
D = 1.6” (40 mm)
E = 2.1” (53 mm)
E31CT3 200 Amp
A = 1.5” (39 mm)
B = 1.25” (32 mm)
C = 1.25” (32 mm)
D = 2.5” (64 mm)
E = 2.8” (71 mm)
B
E
A
C
D
D
E
C
B
A
D
E
B
A
C
E31CT0 50 Amp
A = 1.0” (26 mm)
B = 0.5” (11 mm)
C = 0.4” (10 mm)
D = 0.9” (23 mm)
E = 1.6” (40 mm)
E31CT1 100 Amp
A = 1.5” (39 mm)
B = 0.8” (20 mm)
C = 0.7” (16 mm)
D = 1.6” (40 mm)
E = 2.1” (53 mm)
E31CT3 200 Amp
A = 1.5” (39 mm)
B = 1.25” (32 mm)
C = 1.25” (32 mm)
D = 2.5” (64 mm)
E = 2.8” (71 mm)
B
E
A
C
D
These dimensions apply to
both BCPMSCCTxx (branch
CTs) and LVCT0xxxx0S/1S
(for Mains) 50A-200A CT
families.
53
PLSED309005EN
Multi-circuit metering
PowerLogic BCPM with solid core CT strips installation details
PE86171
PowerLogic BCPM with split core CTs installation details
PE86287
Mains monitoring
(CTs ordered separately)
BCPM PCB
Transducers (1/3 Vac)
Circuit monitoring
4 CT strips monitor 84 circuits
PowerLogic BCPM
Dimensions and connection
Ethernet
Modbus
PowerLogic wireless range is designed to retrot existing switchboards, and
enhance energy efcciency of buildings in operation for many years, by:
bMonitoring energy consumption, to detect potential savings.
bMonitoring operation of the electrical system, to optimize service to the building
occupants.
bPowerLogic EM4300 meters collect a broad scope of electrical data, from the
distribution line they are tted on.
bPowerLogic WT 4200-transmitters collect data from various meters (water, air,
gas, steam etc.) with pulse outputs.
Collected data from both these sources are transmitted to a data concentrator, which
enables their reading by various energy management services and software.
For data concentrators of various types, see:
bCom’X for Ethernet networks
http://www.schneider-electric.com/products/ww/en/82258-energy-and-power-digitization/
82259-interfaces-and-gateways/62072-enerlinx-comx/
bSmartStruXure Lite MPM managers for BACnet, EnOcean, CANbus nest works
http://www.schneider-electric.com/products/ww/en/1200-building-management-system/
1210-building-management-systems/62191-smartstruxure-lite-solution/?BUSINESS=2
Zigbee 2.4 GHz
PowerLogic EM4300 PowerLogic WT4200
Gateway,
data logger,
energy server
Radio Frequency transmission
DB407246
Multi-circuit and
wireless metering PowerLogic EM4300
Wireless metering system
54 PLSED309005EN
Functions
Electrical circuits and loads monitoring, through a combination of power and enerrgy
metering with wireless communication.
Features and benetits
bInstallation time and therefore total cost of ownership is minimized thanks to:
vwireless communication.
vattached exible current sensors, immediately tted around any cable or bar
without disconnection. Power-off time to t several, meters in a switchboard is a
matter of minutes.
bEquipment can be scaled over time, according to savings elds identication, or
other matters of interest.
bBroad scope of collected data make PowerLogic EM4300 of high added-value for:
venergy management.
venergy cost allocations.
velectrical network management and supervision.
Collected information
bEnergy: active, reactive, apparent, phase by phase and aggregated.
bActive, reactive and apparent powers, power factor.
bRMS Voltage and frequency.
bMaximum RMS current and minimum RMS voltage over the last minutes (1 to 30).
Wireless data transmission
bZigbee Pro HA protocol.
b2.4 GHz radio frequency.
bMaximum power: 10 mW (10 dBm).
bCompatible with Com’X and MPM gateways, data loggers and energy servers.
RF Operating range
The recommended distances between the meter and the receiver are shown below:
≤ 5 m (16 ft)
≤ 10 m (32 ft)
Note: Do not install the meter if there is a solid concrete wall between the meter and the gateway.
Certain installation locations or scenarios should be avoided.
bDo not install the meter in front of or close to metallic parts, which may reduce the
efciency of the embedded antenna.
bDo not install in a location that directly blocks the antenna on the meter.
bWireless meters are inside
electrical switchboards.
bWireless receivers are
located in the technical room
with up to 20 meters range.
bLocation of each element
has to match distances as
described on the picture.
bAll barriers, walls or pipes
have to be considered during
the installation. Moving an
element by few centimers
can increse or decrease the
wireless transmission
performance.
bChecking the LQI
(Link Quality Index) is
recommended to build a
robust network.
PowerLogic EM4300
Wireless metering system (cont.)
DB407247
DB407250
Multi-circuit and
wireless metering
55
PLSED309005EN
Commercial reference numbers
Model Current rating Current sensor inner Ø Ref. number
EM4302 200 A 55 mm (2.17 in) METSEEM4302
EM4305 500 A 55 mm (2.17 in) METSEEM4305
EM4310 1000 A 125 mm (4.92 in) METSEEM4310
EM4320 2000 A 125 mm (4.92 in) METSEEM4320
Technical characteristics
Control power
Powered by L1-N measured input voltage 90 V to 300 V - 50/60 Hz
Maximum supply current 4 A
Maximum burden 2.0 W
Measurement characteristics
Input voltage 90 V to 300 V
Frequency range 50/60 Hz
Current range 0 % to 120 % of rated value
(200, 500, 1000 or 2000 A)
Current sensors 3 attached to the meter and calibrated as a
single unit
Accuracy 1 % on active energy (3-phase with neutral)
Mechanical characteristics
Degree of protection (for indoor use only, not
suitable for wet locations)
IP20
IK06
Insulation Class II (IEC 61010-1 CAT III 300 V)
Environmental characteristics
Operating temperature -10°C to 55°C (14°F to 131°F)
Moisture withstand 5 % to 90 % relative humidity, non-condensing,
maximum dewpoint 38°C (100°F)
Pollution degree 2
Voltage surges Category III
Altitude 2000 m (6562 ft) above sea level
Standards compliance
Safety IEC/EN 61010-1 ed. 3, UL 61010-1 ed. 3
Electromagnetic compatibility EN 61326-1:2013
Wireless communication FCC CFR Part 15, subparts and C
PowerLogic EM4300
Wireless metering system (cont.)
Multi-circuit and
wireless metering
56 PLSED309005EN
Dimensions
5.0 mm
(0.2 in)
109.3
(4.30)
100.1
(3.94)
112.2
(4.42)
53.9
(2.12)
mm
( in )
42.6
(1.67)
Ø 4.2
Ø (0.15)
2.9
(0.11)
35.8
(1.41)
38.7
(1.52)
1.5 m
4.9 ft
Model I (A) Ø (mm / in) Weight
EM4302 200 55 / 2.17 *
EM4305 500 55 / 2.17 *
EM4310 1000 125 / 4.92 *
EM4320 2000 125 / 4.92 *
DB407248
Mounting
bDIN-rail or at surface.
bFlexible current sensors around conductor to be monitored.
Max inner Ø 55 or 125 mm. For safe and correct mounting, refer to the installation
guide.
*Please consult your Schenider Electric representative.
PowerLogic EM4300
Wireless metering system (cont.)
DB407249
Multi-circuit and
wireless metering
57
PLSED309005EN
EM4000 series
Functions and characteristics
Multi-circuit energy meters
PB113714
EM4000 series multi-circuit energy meter
The compact PowerLogic EM4000 series multi-circuit energy meter from Schneider
Electric enables reliable monitoring building electrical loads iwith a low installation
cost-per-point by combining revenue-accurate electricity sub-metering with
advanced communications technology.
The EM4000 is ideal for departmental metering applications and M&V within ofce
towers, condominiums, apartment buildings, shopping centres and other multi-user
environments, or small-footprint retail.
The PowerLogic EM4000 series meters monitor up to 24 meter points with a single
device. Multiple meters can be combined to support an unlimited number of points.
Two meter models offer a choice of CTs and installation options:
bPowerLogic EM4033: 333 mV, split-core CTs
bPowerLogic EM4080: 80 mA solid -core CTs
Applications
bEnergy management.
bEnergy cost allocation.
bUtility bill verication.
Main characteristics
Compact, maintenance-free design
Requires no oor space
Hi-density, flexible connection
From single-pole to single- or three-phase metering -- supports up to 24 circuits.
Select the connection type using an intuitive conguration tool.
Direct connection
For 100 - 300 V ac L-N electrical distribution systems:
120/240 V, 120/208 V, 277/480 V
Multiple CT types
Support a variety of needs in both new and retrot installations.
1/3 V output CT option does not require shorting blocks, making it the ideal choice for
retrot installations.
No rewiring required
Use existing wiring to connect to existing panels.
Integrated communications networks.
Onboard Ethernet or RS-485 allows for easy integration into existing
communications networks.
Part numbers
Model Description Part number
EM4033 24 x 333 mV inputs, 120V control power 60 Hz METSEEM403316
24 x 333 mV inputs, 277V control power 60 Hz METSEEM403336
EM4080 24 x 80 mA inputs, 120V control power 60 Hz METSEEM408016
24 x 80 mA inputs, 277V control power 60 Hz METSEEM408036
58 PLSED309005EN
EM4000 series
Functions and characteristics (cont.)
Selection guide EM4033 EM4080
General
Use on LV systems b b
Accuracy +/- 0.5% b b
Accuracy compliance ANSI C12.1 and C12.20 Class 0.5;
IEC 62053-22, Class 0.5S
b b
Maximum circuits:
single-pole / single phase /
three-phase
24 / 12 / 8 b b
Instantaneous rms values
Energy real, kWh received/delivered b b
reactive, kvarh received/delivered b b
apparent, VAh b b
Voltage b b
Pulse counts b b
Voltage and current V rms, I rms per phase b b
Power real, reactive, apparent b b
Power factor b b
Measurements available for data logging
Energy real, kWh received/delivered b b
reactive, kvarh received/delivered b b
apparent, VAh b b
Voltage b b
Display
Backlit LCD display 2 lines of 16 characters b b
Optional remote modular display available b b
Communication
Ethernet port b b
MODBUS-RTU over RS-485 b b
Pulse inputs 2b b
Protocols: Modbus TCP/IP, HTTP, BACnet/IP, FTP, and SNTP b b
Installation options
0.333 V CTs b
80 mA CTs b
Split core CT b
Solid core CT b b
Multi-circuit energy meters
Legend:
1 Cover screw location
2 Meter point input connector
3 Cable connector
4 Mounting keyhole
5 Ingress punch-outs
6 Earth stud
6 Sense voltage terminal block
8 Control voltage terminal block
9 Fuse
10 Control voltage jumper
11 RTU interface
12 Display
13 Remote display connector
14 Serial RS232
15 Ethernet port
16 Pulse in terminal blocks
17 Pulse out connector
PowerLogic EM4000 meter 480Y/277V three-phase wye service
connection
PB113716
PowerLogic EM4033 and PowerLogic EM4080 internal view.
PB113718
PB113716
59
PLSED309005EN
EM4000 series
Functions and characteristics (cont.)
Multi-circuit energy meters
Electrical characteristics
Input-voltage
characteristics
Inputs V1, V2, V3, Vn
Measured voltage 80 - 480 V AC L-L without PTs
Up to 999 kV with external PTs
Frequency range 60 Hz
Mechanical characteristics
Weight EM4033/EM4080 approx. 4.0 kg
Dimensions EM4033/EM4080 33.5 cm x 30.5 cm x 5.5 cm
(13.125 in x 12 in x 2.125 in)
Environmental conditions
Operating temperature -40°C to +70°C (-40°F to +158°F)
Storage temperature -40°C to +70°C (-40°F to +158°F)
Humidity rating 0% to 90 % RH non-condensing
Enclosure Type 1 (indoor or enclosed outdoor use)
Altitude 3000 m (9843 ft)
Pollution degree 2
Safety and standards
UL Certied to IEC/EA/CSA 61010-1
CSA-C22.2 No 61010-1-04
FCC Part 15 Class B
ICES-003 EN55022, IEC 6100-4-5
ANSI/TIA968-A: 2002
Communication
Ports Ethernet
MODBUS-RTU over RS-485
Pulse inputs 2
Protocols: Modbus TCP/IP, HTTP, BACnet/IP,
FTP, and SNTP
Display characteristics
Integrated backlit LCD display 2 lines, 16 digits per line display;
R / L arrow buttons select metering point;
Display button cycles through measurements
per point.
60 PLSED309005EN
EM4000 series
Dimensions and connection
Multi-circuit energy meters
PB113726PB113719
EM4X00, CT termination, PT module
EM4X00, CT termination, PT module
61
PLSED309005EN
EM4000 series
Accessories
Multi-circuit energy meters
PT Module
The PT module provides step-down voltage connections to Schneider Electric
PowerLogic meters for metering single-phase to three-phase voltages of 600V,
347V, or 400V, while meeting all regulatory electrical safety and ANSI 0.5 Accu-
racy Class standards. The PT module provides both the per-phase input metering
voltages and the auxiliary input power required by Schneider Electric PowerLogic
energy meters.
There are two variants of the PT module that support the following source voltages
and wiring congurations:
347V Wye / 600V Delta variant supports:
b347V, three-phase, 4-wire wye
b600V, three-phase, 3-wire delta
480V Delta variant supports:
b480V, three-phase, 3-wire delta
The 347V/600V PT module variant has three sense voltage potential transformers
for metering. The conguration of the transformers (347V wye or 600V delta) is se-
lected by using the jumper provided. The 480V PT module has two sense voltage
potential transformers for metering. There is a separate auxiliary power transformer
in both variants to operate the meter. All voltage inputs are fused.
PowerHawk PT module specications
Dimensions Height 8.39 in. (21.31 cm)
Width 13.53 in. (34.37 cm)
Depth 2.125 in. (5.4 cm)
Weight 112.5 lb (5.67 kg)
Fuse ratings High voltage inputs F1 T315 mA, 1000V
F2 T315 mA, 1000V
F3 T315 mA, 1000V
Voltage inputs F4 T250 mA, 250V
F5 T250 mA, 250V
F6 T250 mA, 250V
F7 T250 mA, 250V
Transformer
specications
Input voltage 600V Voltage tolerance: +/-10%
480V Voltage tolerance: +/-10%
347V Voltage tolerance: +/-10%
Output voltage 120V Accuracy: 0.3%
Environmental Operating temperature -40 to158°F (-40 to 70°C)
Operating humidity 5% to 90% non-condensing
Usage environment Indoor or enclosed outdoor
environment
Maximum altitude 9843 ft (3000 m)
Pollution degree 2
PB113724
Part number Description
METSEPTMOD480 480 V PT Module for EM4X00 meter
METSEPTMOD347600 347 V/600 V PT Module for EM4X00 meter
62 PLSED309005EN
PowerHawk PT module specications
Dimensions Height 8.39 in. (21.31 cm)
Width 13.53 in. (34.37 cm)
Depth 2.125 in. (5.4 cm)
Weight 112.5 lb (5.67 kg)
Fuse ratings High voltage inputs F1 T315 mA, 1000V
F2 T315 mA, 1000V
F3 T315 mA, 1000V
Voltage inputs F4 T250 mA, 250V
F5 T250 mA, 250V
F6 T250 mA, 250V
F7 T250 mA, 250V
Transformer
specications
Input voltage 600V Voltage tolerance: +/-10%
480V Voltage tolerance: +/-10%
347V Voltage tolerance: +/-10%
Output voltage 120V Accuracy: 0.3%
Environmental Operating temperature -40 to158°F (-40 to 70°C)
Operating humidity 5% to 90% non-condensing
Usage environment Indoor or enclosed outdoor
environment
Maximum altitude 9843 ft (3000 m)
Pollution degree 2
PB113725
EM4000 series
Accessories
Multi-circuit energy meters
CT Module
PowerLogic 4080 meters have 2 shorting options that provide a seamless and
sealable mechanical package. The CT Shorting Module provides CT connections
via the color coded 25 pair cable routed into the breaker panel. All CTs are shorted
at the same time for safe removal of the meter for maintenance when the electrical
circuits are still live.
The CT Termination Module has the same shorting ability, but provides CT connec-
tions via 24 2 position screw down terminal blocks. Individual pairs are then routed
from the CT Termination Module to 1 or more breaker panels via conduit knock
outs provided on the module. Thus eliminating the need for a splitter box to route
CT cables to multiple panels.
Part number Description
METSECTTERM CT Termination Module for EM4X00 meter
METSECTSHORT CT Shorting Module for EM4X00 meter
Part number Description
METSECONV580 5 A : 80 mA converter for EM4X00 meter
Converter
The 5A:80mA converter is useful in applications where there are existing 5A CT’s
integrated into large motors or switch gear. The 5A:80mA converter matches the
5A secondary of the load to the 80mA input of the meter. In Billing Grade
applications, the 5A:80mA converter is also used to connect regulatory grade
large aperture, large amperage CT’s with 5A secondaries to the 80mA of
PowerLogic 4X80 meters.
PB113729
The 5 A to 80 mA converter
PB111056
The 5 A to 80 mA converter dimensions
63
PLSED309005EN
Legend:
1 Source
2 Energy ow
3 Load
4 X1
5 X2
PowerLogic EM4033 split-core 0.333V current transformer
EM4000 series
Accessories and dimensions
Multi-circuit energy meters
CTs
bModel 8 (80/100 mA Secondary)
bWindow Size: 3.25” Diameters
bApplication: Metering
bFrequency: 50- 400 Hz
bInsulation Level: 600 Volts, 10Kv BIL Full Wave
bFlexible leads available for all case congurations. Flexible leads are UL 1015
105˚C, C.S.A approved #16 AWG, 24” long standard length. Non- ‐standard lengths
are available upon request.
bTerminals are brass studs No. 8-32 UNC with one at washer, one lock washer
and one nut each. Terminals are only available on the square case conguration.
bMounting brackets kits for the Model 8SHT are available when required.
bApproximate weight: 3 lbs. (1.36 kg)
Part number Description
METSECT80200 CT, solid core, 200 A primary, 80 mA secondary, for
use with EM4X80 multi-circuit meter
METSECT80400 CT, solid core, 400 A primary, 80 mA secondary, for
use with EM4X80 multi-circuit meter
METSECT80600 CT, solid core, 600 A primary, 80 mA secondary, for
use with EM4X80 multi-circuit meter
PB111060
200 A CT dimensions
METSECT80600 600 A 80 mA CT
200 A CT
PB111061
600 A 80 mA CT dimensions
PB111059PB111057
PB111058
400 A CT 400 A CT dimensions
PB113971
PB113972
64 PLSED309005EN
65
PLSED309005EN
EM4800 series
Functions and characteristics
Multi-circuit energy meters
PE86326 PE86325
EM4800 series multi-circuit energy meter
front (above), installed in panel (below)
The compact PowerLogic EM4800 series multi-circuit energy meter from Schneider
Electric enables reliable metering of individual tenants with a low installation
cost-per-point by combining revenue-accurate electricity sub-metering with
advanced communications technology.
The EM4800 is ideal for multi-tenant or departmental metering applications within
ofce towers, condominiums, apartment buildings, shopping centres and other
multi-user environments.
The PowerLogic EM4800 series meters monitor up to 24 tenants with a single
device. Multiple meters can be combined to support an unlimited number of suites.
Three meter models offer a choice of CT secondary ratings and installation options:
PowerLogic EM4805: 5 A, split- or solid-core CTs
PowerLogic EM4880: 80 mA, solid-core CTs
Applications
Multi-tenant metering.
Energy management.
Energy cost allocation.
Utility bill verication.
Main characteristics
Compact, maintenance-free design
Requires no oor space.
Hi-density, flexible connection
From single-pole to single- or three-phase metering -- supports up to 24 circuits.
Select the connection type using an intuitive conguration tool.
Direct connection
For 100 - 300 V ac L-N electrical distribution systems:
120/240 V, 120/208 V, 230/240 V, 220/380 V, 240/415 V, 277/480 V
Multiple CT types
Support a variety of needs in both new and retrot installations.
1/3 V output CT option does not require shorting blocks, making it the ideal choice for
retrot installations.
No rewiring required
Use existing wiring to connect to existing panels.
Integrated communications
Onboard Ethernet and modem allows for easy integration into existing
communications networks.
Part numbers
Model Description Part number
EM4805 24 x 5 A inputs, 230/240 V control power, 50 Hz METSEEM480525
24 x 5 A inputs, 120 V control power, 60 Hz METSEEM480516
EM4880 24 x 80 mA inputs, 230/240 V control power, 50 Hz METSEEM488025
24 x 80 mA inputs, 120 V control power, 60 Hz METSEEM488016
66 PLSED309005EN
EM4800 series
Functions and characteristics (cont.)
PE86327A
PowerLogic EM4800 series digital panel meter.
Selection guide EM4805 EM4880
General
Use on LV systems b b
Accuracy +/- 0.5% b b
Accuracy compliance ANSI C12.1 and C12.20 Class 0.5;
IEC 62053-22, Class 0.5S
b b
Maximum circuits:
single-pole / single phase /
three-phase
24 / 12 / 8 b b
Instantaneous rms values
Energy real, kWh received/delivered b b
reactive, kvarh received/delivered b b
apparent, VAh b b
Voltage b b
Pulse counts b b
Voltage and current V rms, I rms per phase b b
Power real, reactive, apparent b b
Power factor b b
Measurements available for data logging
Energy real, kWh received/delivered b b
reactive, kvarh received/delivered b b
apparent, VAh b b
Voltage b b
Display
Backlit LCD display 2 lines of 16 characters b b
Optional remote modular display available b b
Communication
Ethernet port b b
V.90 modem port b b
Pulse inputs 2b b
Protocols: Modbus TCP/IP, HTTP, BACnet/IP, FTP, and SNTP b b
Installation options
5 A CTs b
80 mA CTs b
Split core CT b
Solid core CT b b
Remore modular display b b
Multi-circuit energy meters
67
PLSED309005EN
EM4800 series
Functions and characteristics (cont.)
Multi-circuit energy meters
Electrical characteristics
Input-voltage
characteristics
Inputs V1, V2, V3, Vn
Measured voltage 80 - 480 V AC L-L without PTs
Up to 999 kV with external PTs
Frequency range 50/60 Hz
Mechanical characteristics
Weight EM4805 approx. 5.4 kg
EM4833 / EM4880 approx. 4.0 kg
Dimensions EM4805 33.5 cm x 44 cm x 5.5 cm
(13.125 in x 17 in x 2.125 in)
EM4833 / EM4880 33.5 cm x 30.5 cm x 5.5 cm
(13.125 in x 12 in x 2.125 in)
Environmental conditions
Operating temperature -40°C to +70°C (-40ºF to +158°F)
Storage temperature -40°C to +70°C (-40ºF to +158°F)
Humidity rating 0% to 90 % RH non-condensing
Enclosure Type 1 (indoor or enclosed outdoor use)
Altitude 3000 m (9843 ft)
Pollution degree 2
Safety and standards
UL Certied to IEC/EA/CSA 61010-1
CSA-C22.2 No 61010-1-04
FCC Part 15 Class B
ICES-003 EN55022, IEC 6100-4-5
ANSI/TIA968-A: 2002
Communication
Ports Ethernet
V.90 modem
Pulse inputs 2
Protocols: Modbus TCP/IP, HTTP, BACnet/IP,
FTP, and SNTP
Display characteristics
Integrated backlit LCD display 2 ines, 16 digits per line display;
R / L arrow buttons select metering point;
Display button cycles through measurements
per point.
68 PLSED309005EN
Power Meter Series PM3200
Functions and characteristics
Basic multi-function metering
PB108433
This PowerLogic Power meter offers basic to advanced measurement capabilities.
With compact size and DIN rail mounting, the PM3200 allows mains and feeders
monitoring in small electrical cabinets. Combined with current transformers and
voltage transformers, these meters can monitor 2-, 3- and 4-wire systems. The
graphic display has intuitive navigation to easily access important parameters.
Four versions are available offering basic to advanced applications:
b PM3200
v Electrical parameters I, In, U, V, PQS, E, PF, Hz
v Power/current demand
v Min/max.
b PM3210
v Electrical parameters I, In, U, V, PQS, E, PF, Hz, THD
v Power/current demand, peak demand
v Min/max.
v 5 timestamped alarms
v kWh pulse output
b PM3250
v Electrical parameters I, In, U, V, PQS, E, PF, Hz, THD
v Power/current demand, peak demand
v Min/max.
v 5 timestamped alarms
v LED to indicate communications
v RS485 port for Modbus communication
b PM3255
v Electrical parameters I, In, U, V, PQS, E, PF, Hz, THD
v Power/current demand and peak demand
v Flexible power and energy data logging
v Min/max. and 15 timestamped alarms
v LED to indicate communications
v Up to 4 tariffs management
v 2 digital inputs, 2 digital outputs
v Memory for load prole (demand 10mn to 60mn)
v RS485 port for Modbus communication
bInnovative design makes the meters smart and simple:
bEasy to install for panel builders
bEasy to commission for contractors and installers
bEasy to operate for end users
Applications
Cost management applications
b�Bill checking
bSub-billing, including WAGES view
bCost allocation, including WAGES view
Network management applications
bPanel instrumentation
bUp to 15 onboard timestamped alarms to monitor events
bEasy integration with PLC system by input/output interface
Market segments
bBuildings
bIndustry
bData centres and networks
bInfrastructure (airports, road tunnels, telecom)
Part numbers
Power Meter Series PM3200
PB108435
Power Meter Series PM3255
Meter model and description Performance Part no.
PM3200 basic power meter Basic power meter METSEPM3200
PM3210 power meter with pulse output Power, current, THD, peak demand METSEPM3210
PM3250 power meter with RS485 port Power, current, THD, peak demand METSEPM3250
PM3255 power meter plus 2 digital inputs,
2 digital outputs with RS485 port
Power, current, THD, peak demand,
memory for load prole
METSEPM3255
Front of meter parts
1 Control power
2 Display with white backlit
3 Flashing yellow meter indicator (to check accuracy)
4 Pulse output for remote transfer (PM3210)
5 Cancellation
6 Conrmation
7 Up
8 Down
69
PLSED309005EN
Basic multi-function metering Power Meter Series PM3200
Functions and characteristics (cont.)
Function guide PM3200 Range
PM3200 PM3210 PM3250 PM3255
Performance standard
IEC61557-12 PMD/Sx/K55/0.5 bbbb
General
Use on LV and HV systems bbbb
Number of samples per cycle 32 32 32 32
CT input 1A/5A bbbb
VT input bbbb
Multi-tariff 4 4 4 4
Multi-lingual backlit display bbbb
Instantaneous rms values
Current, voltage Per phase and average bbbb
Active, reactive, apparent power Total and per phase bbbb
Power factor Total and per phase bbbb
Energy values
Active, reactive and apparent energy; import and export bbbb
Demand value
Current, power (active, reactive, apparent) demand; present bbbb
Current, power (active, reactive, apparent) demand; peak bbb
Power quality measurements
THD Current and voltage bbb
Data recording
Min/max of the instantaneous values bbbb
Power demand logs b
Energy consumption log (day, week, month) b
Alarms with time stamping 5 5 15
Digital inputs/digital outputs 0/1 2/2
Communication
RS-485 port b b
Modbus protocol b b
PB108434
Connectivity advantages
Programmable digital input External tariff control signal (4 tariffs)
Remote Reset partial counter
External status like breaker status
Collect WAGES pulses
Programmable digital output Alarm (PM3255)
kWh pulses
Graphic LCD display Backlit graphic display allows smart navigation in relevant
information and in multi languages
Communication Modbus RS485 with screw terminals allows connection to a
daisy chain
Power Meter Series PM3210
70 PLSED309005EN
Power Meter Series PM3200
Functions and characteristics (cont.)
Basic multi-function metering
Specications PM3200 Range
Type of measurement True rms up to the 15th harmonic on three-phase (3P,3P+N) and single-phase
AC systems. 32 samples per cycle
Measurement accuracy
Current with x/5A CTs 0.3% from 0.5A to 6A
Current with x/1A CTs 0.5% from 0.1A to 1.2A
Voltage 0.3% from 50V to 330V (Ph-N), from 80V to 570V (Ph-Ph)
Power factor ±0.005 from 0.5A to 6A with x/5A CTs; from 0.1A to 1.2A with x/1A CTs and from
0.5L to 0.8C
Active/Apparent Power with x/5A CTs Class 0.5
Active/Apparent Power with x/1A CTs Class 1
Reactive power Class 2
Frequency 0.05% from 45 to 65Hz
Active energy with x/5A CTs IEC62053-22 Class 0.5s
Active energy with x/1A CTs IEC62053-21 Class 1
Reactive energy IEC62053-23 Class 2
Data update rate
Update rate 1s
Input-voltage characteristics
Measured voltage 50V to 330V AC (direct / VT secondary Ph-N)
80V to 570V AC (direct / VT secondary Ph-Ph)
up to 1MV AC (with external VT)
Frequency range 45Hz to 65Hz
Input-current characteristics
CT primary Adjustable from 1A to 32767A
CT secondary 1A or 5A
Measurement input range with x/5A CTs 0.05A to 6A
Measurement input range with x/1A CTs 0.02A to 1.2A
Permissible overload 10A continuous, 20A for 10s/hour
Control Power
AC 100/173 to 277/480V AC (+/-20%), 3W/5VA; 45Hz to 65Hz
DC 100 to 300V DC, 3W
Input
Digital inputs (PM3255) 11 to 40V DC, 24V DC nominal, <=4mA maximum burden, 3.5kVrms insulation
Output
Digital output (PM3210) Optocoupler, polarity sensitive, 5 to 30V, 15mA max, 3.5kVrms insulation
Digital outputs (PM3255) Solid state relay, polarity insensitive, 5 to 40V, 50mA max, 50Ω max,
3.5kVrms insulation
71
PLSED309005EN
Basic multi-function metering Power Meter Series PM3200
Functions and characteristics (cont.)
Specications (continued) PM3200 Range
Mechanical characteristics
Weight 0.26kg
IP degree of protection (IEC60529) IP40 front panel, IP20 meter body
Dimension 90 x 95 x 70mm
Environmental conditions
Operating temperature -25 ºC to +55 ºC
Storage temperature -40 ºC to +85 ºC
Humidity rating 5 to 95% RH at 50ºC (non-condensing)
Pullution degree 2
Metering category III, for distribution systems up to 277/480VAC
Dielectric withstand As per IEC61010-1, Doubled insulated front panel display
Altitude 3000m max
Electromagnetic compatibility
Electrostatic discharge Level IV (IEC61000-4-2)
Immunity to radiated elds Level III (IEC61000-4-3)
Immunity to fast transients Level IV (IEC61000-4-4)
Immunity to surge Level IV (IEC61000-4-5)
Conducted immunity Level III (IEC61000-4-6)
Immunity to power frequency magnetic elds 0.5mT (IEC61000-4-8)
Conducted and radiated emissions Class B (EN55022)
Safety
CE as per IEC61010-1 (1)
Communication
RS485 port Half duplex, from 9600 up to 38400 bauds, Modbus RTU (double insulation)
Display characteristics
Dimensions (VA) 43mm x 34.6mm
Display resolution 128 x 96 dots
Standard compliance
IEC61557-12, EN61557-12
IEC61010-1, UL61010-1
IEC62052-11, IEC62053-21, IEC62053-22, IEC62053-23
EN50470-1, EN50470-3
(1) Protected throughout by double insulation
Multi-tariff capability
The PM3200 range allows arrangement of kWh
consumption in four different registers. This can be
controlled by:
b Digital Inputs. Signal can be provided by PLC or utilities
b Internal clock programmable by HMI
b Through communication
This function allows users to:
b Make tenant metering for dual source applications to
differentiate backup source or utility source
b Understand well the consumption during working time
and non working time, and between working days and
weekends
b Follow up feeders consumption in line with utility tariff
rates
Power Meter Series PM3250
72 PLSED309005EN
Power Meter Series PM3200
Dimensions and connection
Basic multi-function metering
PM3200 series dimensions
PB105302
PM3200 top and lower aps PM3200 series easy installation
PB105446
73
PLSED309005EN
Basic multi-function metering PM5350
Functions and characteristics
PE86278
PowerLogic PM5350.
The PowerLogic PM5350 power meter offers all the measurement capabilities
required to monitor an electrical installation in a single 96 x 96 mm unit extending
only 44 mm behind the mounting surface.
With its large display, all three phases and neutral can be monitored simultaneously.
The bright, anti-glare display features large characters and powerful backlighting for
easy reading even in extreme lighting conditions and viewing angles. The meter
menus are understood by all, with the availability of three languages (English,
Chinese, Spanish) included standard in the PM5350.
Its compact size and high performance make the PowerLogic PM5350 suitable for
many applications.
Applications
Panel instrumentation.
Cost allocation or energy management.
Electrical installation remote monitoring.
Alarming with under/over, digital status, control power failure, meter reset,
self diagnostic issue.
Circuit Breaker monitoring and control with relay outputs and whetted digital inputs.
Main characteristics
Easy to install
Mounts using two clips, no tools required. Ultra compact meter with 44mm depth
connectable up to 480 VL-L without voltage transformers for installations compliant
with category III, as per IEC 61010-1. See specication table for UL voltage limits.
Easy to operate
Intuitive navigation with self-guided, language selectable menus, six lines, four
concurrent values. Two LEDs on the meter face help the user conrm normal
operation (heartbeat/communications indicator LED: green and other LED orange,
customizable either for alarms or energy pulse outputs).
Easy circuit breaker monitoring and control
The PM5350 provides two relay outputs (high performance) with capability to
command most of the circuit breaker coils directly. In addition, monitored switches
can be wired directly to the meter without external power supply.
System status at a glance
Bright, anti-glare, backlit display plus two LEDs; orange for energy pulse or alarm
and green for heartbeat/communications indication.
IEC 62053-22 class 0.5S accuracy for active energy
Accurate energy measurement for cost allocation.
Power Quality analysis
The PM5350 offers THD and TDD measurements as standard. Total Demand
Distortion is based on a point of common coupling (PCC), which is a common point
that each user receives power from the power source. The TDD compares the
contribution of harmonics versus the maximum demand load.
Load management
Peak demands with time stamping are provided. Predicted demand values can be
used in basic load shedding applications.
Alarming with time stamping
Over 30 alarm conditions, such as under/over conditions, digital input changes, and
phase unbalance inform you of events. A time-stamped log maintains a record of the
last 40 alarm events.
Load timer
Load timer setpoint adjustable to monitor and advise maintenance requirements.
Performance Standard Meets IEC 61557-12 PMD/S/K70/0.5.
Part numbers
PowerLogic PM5350 meters
PowerLogic PM5350 METSEPM5350
74 PLSED309005EN
Basic multi-function metering PM5350
Functions and characteristics (cont.)
General
Use on LV and MV systems b
Basic metering with THD and min/max readings b
Instantaneous rms values
Current Total, Phases and neutral b
Voltage Total, Ph-Ph and Ph-N b
Frequency b
Real, reactive, and
apparent power
Total and per phase Signed
True Power Factor Total and per phase Signed, Four Quadrant
Displacement PF Total and per phase Signed, Four Quadrant
Unbalanced I, VL-N, VL-L b
Energy values Stored in
non-volatile
memory
Accumulated Active, Reactive and Apparent Energy Received/Delivered;
Net and absolute;
b
Demand values
Current average Present, Last, Predicted,
Peak, & Peak Date Time
b
Active power Present, Last, Predicted,
Peak, & Peak Date Time
b
Reactive power Present, Last, Predicted,
Peak, & Peak Date Time
b
Apparent power Present, Last, Predicted,
Peak, & Peak Date Time
b
Peak demand with timestamping D/T for current & powers b b
Demand calculation Sliding, xed and rolling block,
thermal
b b
Synchronization of the measurement window b b
Other measurements
I/O timer b b
Operating timer b b
Active load timer b b
Alarm counters b b
Power quality measurements
THD, thd (Total Harmonic Distortion) I,VLN, VLL
TDD, thd (Total Demand Distortion) b
Data recording
Min/max of instantaneous values, plus phase
identication
b b
Alarms with 1s timestamping Standard 29; Unary 4;
Digital 4
Alarms stored in non-volatile memory 40 events b
Inputs/Outputs
Digital inputs 4 (DI1, DI2, DI3, DI4)
Digital outputs 2 relay outputs (DO1,
DO2)
Display
White backlit LCD display, 6 lines, 4 concurrent values b
IEC or IEEE visualization mode b
Communication
Modbus RTU, Modbus ASCII, Jbus Protocol b
Firmware update via RS485 serial port
(DLF3000 via the Schneider Electric website:
www.schneider-electric.com)
b
75
PLSED309005EN
Basic multi-function metering PM5350
Functions and characteristics (cont.)
Front screen view of PM5350.
Electrical characteristics
PE86292
Type of measurement True rms up to the 15th harmonic on three-phase
(3P, 3P + N)
32 samples per cycle, zero blind
Measurement
accuracy
Current, Phase (1)±0.30%
Voltage, L-N (1)±0.30%
Power Factor (1)±0.005
Power, Phase IEC 61557-12 Class 0.5; For 5 A nominal CT (for 1 A
nominal CT when I > 0.15A)
±0.5% from 0.25 A to 9.0 A at COS φ = 1
±0.6% from 0.50 A to 9.0 A at COS φ = 0.5 (ind or cap)
Frequency (1)±0.05%
Real Energy IEC 62053-22 Class 0.5S; IEC 61557-12 Class 0.5;
For 5 A nominal CT (for 1 A nominal CT when I > 0.15A)
±0.5% from 0.25 A to 9.0 A at COS φ = 1
±0.6% from 0.50 A to 9.0 A at COS φ = 0.5 (ind or cap)
IEC 61557-12 Class 0.5
Reactive Energy IEC 62053-23 Class 3, IEC 61557-12 Class 2
For 5 A nominal CT (for 1 A nominal CT when I > 0.15A)
±2.0% from 0.25 A to 9.0 A at SIN φ = 1
±2.5% from 0.50 A to 9.0 A at SIN φ = 0.5 (ind or cap)
Data update rate 1 second nominal (50/60 cycles)
Input-voltage VT primary 1.0 MV AC max, starting voltage depends on VT ratio.
U nom 277 V L-N
Measured voltage with
overrange & Crest Factor
IEC: 20 to 480 V AC L-L; 20 to 277 V AC L-N, CAT III
IEC: 20 to 690 V AC L-L; 20 to 400 V AC L-N, CAT II
UL: 20 to 300 V AC L-L, CAT III
Permanent overload 700 Vac L-L, 404 Vac L-N
Impedance 10 M ww
Frequency range 45 to 70 Hz
Input-current CT ratings Primary Adjustable 1 A to 32767 A
Secondary 1A, 5 A nominal
Measured voltage with
overrange & Crest Factor
5 mA to 9 A
Withstand Continuous 20 A,10 sec/hr 50 A,1 sec/hr 500 A
Impedance < 0.3 mW
Frequency range 45 to 70 Hz
Burden < 0.024 VA at 9 A
AC control
power
Operating range 85 - 265 V AC
Burden 4.1 VA / 1.5 W typical, 6.7 VA / 2.7 W max at 120 V AC
6.3 VA / 2.0 W typical, 8.6 VA / 2.9 W max at 230 V AC
9.6 VA / 3.5 W maximum at 265 V AC
Frequency 45 to 65 Hz
Ride-through time 100 mS typical at 120 V AC and maximum burden
400 mS typical at 230 V AC and maximum burden
DC control
power
Operating range 100 to 300 V DC
Burden 1.4 W typical, 2.6 W maximum at 125 V DC
1.8 W typical, 2.7 W maximum at 250 V DC
3.2 W maximum at 300 V DC
Ride-through time 50 mS typical at 125 V DC and maximum burden
Real time clock Ride-through time 30 seconds
Digital output Number/Type 2 - Mechanical Relays
Output frequency 0.5 Hz maximum (1 second ON / 1 second OFF -
minimum times)
Switching Current 250 V AC at 2.0 Amps, 200 k cycles, resistive
250 V AC at 8.0 Amps, 25 k cycles, resistive
250 V AC at 2.0 Amps, 100 k cycles, COSΦ=0.4
250 V AC at 6.0 Amps, 25 k cycles, COSΦ=0.4
30 V DC at 2.0 Amps, 75 k cycles, resistive
30 V DC at 5.0 Amps, 12.5 k cycles, resistive
Isolation 2.5 kVrms
Status Digital
Inputs
Voltage ratings ON 18.5 to 36 V DC, OFF 0 to 4 V DC
Input Resistance 110 k W
Maximum Frequency 2 Hz (T ON min = T OFF min = 250 ms)
Response Time 10 ms
Isolation 2.5 kVrms
Whetting output Nominal voltage 24 V DC
Allowable load 4 mA
Isolation 2.5 kVrms
(1) Measurements taken from 45 Hz to 65 Hz, 0.5 A to 9 A, 57 V to 347 V & 0.5 ind to 0.5 cap
power factor with a sinusoidal wave.
76 PLSED309005EN
Basic multi-function metering PM5350
Functions and characteristics (cont.)
Mechanical characteristics
Weight 250 g
IP degree of protection (IEC 60529) IP51 front display, IP30 meter body
Dimensions W x H x D 96 x 96 x 44 mm (depth of meter from housing
mounting ange)
96 x 96 x 13 mm (protrusion of meter from housing ange)
Mounting position Vertical
Panel thickness 6.35 mm maximum
Environmental characteristics
Operating
temperature
Meter -25 °C to 70 °C
Display -20 °C to +70 °C
(Display functions to -25°C with reduced performance)
Storage temp. Meter + display -40 °C to +85 °C
Humidity rating 5 to 95 % RH at 50 °C (non-condensing)
Pollution degree 2
Altitude 3000 m max.
Electromagnetic compatibility
Electrostatic discharge IEC 61000-4-2(1)
Immunity to radiated elds IEC 61000-4-3(1)
Immunity to fast transients IEC 61000-4-4(1)
Immunity to impulse waves IEC 61000-4-5(1)
Conducted immunity IEC 61000-4-6(1)
Immunity to magnetic elds IEC 61000-4-8(1)
Immunity to voltage dips IEC 61000-4-11(1)
Radiated emissions FCC part 15 class A, EN 55011 Class A
Conducted emissions FCC part 15 class A, EN 55011 Class A
Harmonics IEC 61000-3-2(1)
Flicker emissions IEC 61000-3-3(1)
Safety
Europe e, as per IEC 61010-1
U.S. and Canada cULus as per UL61010-1, IEC 61010-1 (3rd Edition)
Measurement category (Voltage and
current inputs)
Per IEC 61010-1:
CAT III, 277 V L-N / 480 V L-L nominal;
CAT II 400 V L-N / 690 V L-L nominal
Per UL 61010-1 and CSA C22.2 No. 61010-1:
CAT III, 300 V L-L
Overvoltage Category (Control power) CAT III
Dielectric As per IEC 61010-1
Double insulated front panel display
Protective Class II
Communication
RS 485 port 2-Wire, 9600,19200 or 38400 baud, Parity - Even, Odd,
None, 1 stop bit if parity Odd or Even, 2 stop bits if None;
Modbus RTU, Modbus ASCII (7 or 8 bit), JBUS
Firmware and language le update Update via comunication port using DLF3000 software
Isolation 2.5 kVrms, double insulated
Human machine interface
Display type Monochrome Graphics LCD
Resolution 128 x 128
Backlight White LED
Viewable area (W x H) 67 x 62.5 mm
Keypad 4-button
Indicator Heartbeat / Comm activity Green LED
Energy pulse output / Active alarm indication (congurable)
Type Optical, amber LED
Wavelength 590 to 635 nm
Maximum pulse rate 2.5 kHz
(1) As per IEC 61557-12
77
PLSED309005EN
Basic multi-function metering PM5350 Power Meter
Dimensions and connection
Rear of meter - open
PE86279
Rear view retainers - installation
PE86274
For detailed installation instructions see the product's Installation guide.
78 PLSED309005EN
Basic multi-function metering PM5350 Power Meter
Dimensions and connection (cont.)
Rear view retainers - users
PE86275
For detailed installation instructions see the product's Installation guide.
PM5350 meter parts
A Retainer clips.
B Control power supply connector.
C Voltage inputs.
D Digital outputs.
E Rs485 port (COM1).
F Digital outputs.
G Optical revenue switch.
H Current inputs.
PE86324
PE86323
79
PLSED309005EN
Basic multi-function metering PM5350IB / PM5350PB
Functions and characteristics
PE86278
PowerLogic PM5350IB
The PM5350IB and PM5350PB are compact multi-circuit power meters specially
designed to monitor Busway power distribution systems. They provide consumption
and alarm data by circuit, for up to three single phase circuits. It can also be installed
in different electrical congurations, monitoring 1, 2 and 3 phase circuits. Ideal
solution for cost management and sub-billing in datacenters.
With its large display, all individual circuits can be monitored simultaneously. The
bright, anti-glare display features large characters and powerful backlighting for easy
reading even in extreme lighting conditions and viewing angles.
Main characteristics
Easy to install
Mounts using two clips, no tools required. Ultra compact meter with 44mm depth
connectable up to 480 V L-L without voltage transformers. See specication table for
voltage inputs details.
Easy to operate
Intuitive navigation with self-guided, language selectable menus, six lines, four
concurrent values.
System status at a glance
Bright, anti-glare, backlit display plus two LEDs; orange for energy pulse or alarm
and green for heartbeat/communications indication.
IEC 62053-22 class 0.5S accuracy for active energy
Accurate energy measurement for cost allocation and sub-billing.*
Circuit breaker monitoring
Four digital inputs provide an easy way to monitor status, alarm and report on circuit
breaker trips.
Multi-level alarming
Five different alarm levels (high, high-high, low, low-low, tripped) optimized network
management and downtime prevention.
Performance Standard Meets IEC 61557-12 PMD/S/K70/0.5.
PowerLogic PM5350IB/PB meters
PowerLogic PM5350IB METSEPM5350IB
PowerLogic PM5350PB METSEPM5350PB
Part Numbers
80 PLSED309005EN
Basic multi-function metering PM5350IB / PM5350PB
Functions and characteristics (cont.)
General 5350IB 5350PB
Use on LV and MV systems b
Basic metering with THD and min/max readings b
Instantaneous rms values
Current Total, Phases and neutral b
Voltage Total, Ph-Ph and Ph-N b
Frequency b
Real, reactive, and
apparent power
Total and per phase Signed
True Power Factor Total and per phase Signed, Four Quadrant
Displacement PF Total and per phase Signed, Four Quadrant
Unbalanced I, VL-N, VL-L b
Energy Total and per circuit
Accumulated Active, Reactive
and Apparent Energy*
Received/Delivered;
Net and absolute
b
Demand values
Current average* Present, Last, Predicted,
Peak, & Peak Date Time
b
Active power*Present, Last, Predicted,
Peak, & Peak Date Time
b
Reactive power*Present, Last, Predicted,
Peak, & Peak Date Time
Apparent power*Present, Last, Predicted,
Peak, & Peak Date Time
b
Peak demand with timestamping*b
Power quality
THD, thd (Total Harmonic Distortion)
TDD, thd (Total Demand Distortion)
I,VLN, VLL
b
Data recording Total and per circuit
Min/max of instantaneous values, plus circuit
identication*
b
Alarms with 1s timestamping Standard 29; Unary 4; Digital 4
Alarms stored in non-volatile memory*40 events b
Inputs/Outputs
Digital inputs 4 (DI1, DI2, DI3, DI4)
Digital outputs 2 relay outputs (DO1, DO2)
Display
White backlit LCD display, 6 lines, 4 concurrent values b
IEC or IEEE visualization mode b
Communication
Modbus RTU, Modbus ASCII, Jbus Protocol b
Firmware update via RS485 serial port
(DLF3000 via the Schneider Electric website:
www.schneider-electric.com)
b
*Stored in non-volatile memory
81
PLSED309005EN
Basic multi-function metering PM5350IB / PM5350PB
Functions and characteristics (cont.)
Front screen view of PM5350.
Electrical characteristics 5350IB 5350PB
PE86292
Type of measurement True rms up to the 15th harmonic
32 samples per cycle, zero blind
Measurement
accuracy
Current, Circuit (1)±0.30%
Voltage, L-N (1)±0.30%
Power Factor (1)±0.005
Power, Circuit IEC 61557-12 Class 0.5; For 5 A nominal CT (for 1 A
nominal CT when I > 0.15A)
±0.5% from 0.25 A to 9.0 A at COS φ = 1
±0.6% from 0.50 A to 9.0 A at COS φ = 0.5 (ind or cap)
Frequency (1)±0.05%
Real Energy IEC 62053-22 Class 0.5S; IEC 61557-12 Class 0.5;
For 5 A nominal CT (for 1 A nominal CT when I > 0.15A)
±0.5% from 0.25 A to 9.0 A at COS φ = 1
±0.6% from 0.50 A to 9.0 A at COS φ = 0.5 (ind or cap)
IEC 61557-12 Class 0.5
Reactive Energy IEC 62053-23 Class 3, IEC 61557-12 Class 2
For 5 A nominal CT (for 1 A nominal CT when I > 0.15A)
±2.0% from 0.25 A to 9.0 A at SIN φ = 1
±2.5% from 0.50 A to 9.0 A at SIN φ = 0.5 (ind or cap)
Data update rate 1 second nominal (50/60 cycles)
Input-voltage VT primary 1.0 MV AC max, starting voltage depends on VT ratio.
U nom 277 V L-N
Measured voltage with
overrange & Crest Factor
UL: 20 to 300 V AC L-L
IEC: 20 to 690V V AC L-L;
20 to 400 V AC L-N
UL: 20 to 480 V AC L-L
IEC: 20 to 690 V V AC
L-L; 20 to 277 V AC L-N
Permanent overload 700 V AC L-L, 404 Vac L-N
Impedance 10 M W
Frequency range 45 to 70 Hz
Input-current CT ratings Primary Adjustable 1 A to 32767 A
Secondary 1A, 5 A nominal
Measured voltage with
overrange & Crest Factor
5 mA to 9 A
Withstand Continuous 20 A,10 sec/hr 50 A,1 sec/hr 500 A
Impedance < 0.3 mW
Frequency range 45 to 70 Hz
Burden < 0.024 VA at 9 A
AC control
power
Operating range 85 - 277 V AC
Burden 4.1 VA / 1.5 W typical, 6.7 VA / 2.7 W max at 120 V AC
6.3 VA / 2.0 W typical, 8.6 VA / 2.9 W max at 230 V AC
9.6 VA / 3.5 W maximum at 265 V AC
Frequency 45 to 65 Hz
Ride-through time 100 mS typical at 120 V AC and maximum burden
400 mS typical at 230 V AC and maximum burden
DC control
power
Operating range 100 to 300 V DC
Burden 1.4 W typical, 2.6 W maximum at 125 V DC
1.8 W typical, 2.7 W maximum at 250 V DC
3.2 W maximum at 300 V DC
Ride-through time 50 mS typical at 125 V DC and maximum burden
Real time clock Ride-through time 30 seconds
Digital output Number/Type 2 - Mechanical Relays
Output frequency 0.5 Hz maximum (1 second ON / 1 second OFF -
minimum times)
Switching Current 250 V AC at 2.0 Amps, 200 k cycles, resistive
250 V AC at 8.0 Amps, 25 k cycles, resistive
250 V AC at 2.0 Amps, 100 k cycles, COSΦ=0.4
250 V AC at 6.0 Amps, 25 k cycles, COSΦ=0.4
30 V DC at 2.0 Amps, 75 k cycles, resistive
30 V DC at 5.0 Amps, 12.5 k cycles, resistive
Isolation 2.5 kVrms
Status Digital
Inputs
Voltage ratings ON 18.5 to 36 V DC, OFF 0 to 4 V DC
Input Resistance 110 k W
Maximum Frequency 2 Hz (T ON min = T OFF min = 250 ms)
Response Time 10 ms
Isolation 2.5 kVrms
Whetting output Nominal voltage 24 V DC
Allowable load 4 mA
Isolation 2.5 kVrms
(1) Measurements taken from 45 Hz to 65 Hz, 0.5 A to 9 A, 57 V to 347 V & 0.5 ind to 0.5 cap
power factor with a sinusoidal wave.
82 PLSED309005EN
Basic multi-function metering PM5350IB / PM5350PB
Functions and characteristics (cont.)
Mechanical characteristics 5350IB 5350PB
Weight 250 g
IP degree of protection (IEC 60529) IP51 front display, IP30 meter body
Dimensions W x H x D 96 x 96 x 44 mm (depth of meter from housing
mounting ange)
96 x 96 x 13 mm (protrusion of meter from housing ange)
Mounting position Vertical
Panel thickness 6.35 mm maximum
Environmental characteristics (for indoor use only)
Operating
temperature
Meter -25 °C to 70 °C
Display -20 °C to +70 °C
(Display functions to -25°C with reduced performance)
Storage temp. Meter + display -40 °C to +85 °C
Humidity rating 5 to 95 % RH at 50 °C (non-condensing)
Pollution degree 2
Altitude 3000 m max.
Electromagnetic compatibility (for indoor use only)
Electrostatic discharge IEC 61000-4-2(2)
Immunity to radiated elds IEC 61000-4-3(2)
Immunity to fast transients IEC 61000-4-4(2)
Immunity to impulse waves IEC 61000-4-5(2)
Conducted immunity IEC 61000-4-6(2)
Immunity to magnetic elds IEC 61000-4-8(2)
Immunity to voltage dips IEC 61000-4-11(2)
Radiated emissions FCC part 15 class A, EN 55011 Class A
Conducted emissions FCC part 15 class A, EN 55011 Class A
Harmonics IEC 61000-3-2(2)
Flicker emissions IEC 61000-3-3(2)
Safety
Europe e, as per IEC 61010-1
U.S. and Canada cULus as per UL61010-1, IEC 61010-1 (2nd Edition)
Measurement category (Voltage and
current inputs)
UL: 20 to 300 V AC L-L,
CATIII
IEC: 20 to 480V V AC L-L;
20 to 277 V AC L-N,
CATIII
20 to 690V V AC L-L; 20
to 400 V AC L-N, CATII
UL: 20 to 480 V AC L-L
(3rd Edition), CATIII
IEC: 20 to 480V V AC L-L;
20 to 277 V AC L-N,
CATIII
20 to 690V V AC L-L; 20
to 400 V AC L-N, CATII
Overvoltage Category (Control power) CAT III
Dielectric As per IEC 61010-1
Double insulated front panel display
Protective Class II
Communication
RS 485 port 2-Wire, 9600,19200 or 38400 baud, Parity - Even, Odd,
None, 1 stop bit if parity Odd or Even, 2 stop bits if None;
Modbus RTU, Modbus ASCII (7 or 8 bit), JBUS
Firmware and language le update Update via comunication port using DLF3000 software
Isolation 2.5 kVrms, double insulated
Human machine interface
Display type Monochrome Graphics LCD
Resolution 128 x 128
Backlight White LED
Viewable area (W x H) 67 x 62.5 mm
Keypad 4-button
Indicator Heartbeat / Comm activity Green LED
Energy pulse output / Active alarm indication (congurable)
Type Optical, amber LED
Wavelength 590 to 635 nm
Maximum pulse rate 2.5 kHz
(1) V L-L is limited to 700 V AC
83
PLSED309005EN
Basic multi-function metering PM5350 Power Meter
Dimensions and connection
Parts of PM5350IB and PM5350PB (rear panel door removed)
PM5350PB
PM5350IB
PB113626PB113626
For detailed installation instructions see the product's Installation guide.
A Control power
B Voltage inputs
C Current inputs
D Digital inputs
E Whetting voltage source (for digital inputs)
F RS-485 communications
G Digital outputs
H Retainer clips
84 PLSED309005EN
Basic multi-function metering PM5350IB / PM5350PB
Dimensions and connection (cont.)
Installation
PM5350PB
For detailed installation instructions see the product's Installation guide.
PM5350IB
PB113742PB113743
PB113624
PB113625
Dimensions PM5350PB
Dimensions PM5350IB
85
PLSED309005EN
Basic multi-function metering PM5000 Series
Functions and characteristics
PB111777
PowerLogic PM5000 Series meter
PowerLogic PM5100, PM5300 and PM5500 series
The PowerLogic PM5000 power meter is the ideal t for cost management
applications. It provides the measurement capabilities needed to allocate energy usage,
perform tenant metering and sub-billing, pin-point energy savings, optimize equipment
efciency and utilization, and perform a high level assessment of the power quality of the
electrical network.
In a single 96 x 96 mm unit, with a graphical display, (plus optional remote display) all
three phases, neutral and ground can be monitored simultaneously.
The bright, anti-glare display features large characters and powerful backlighting
for easy reading even in extreme lighting conditions and viewing angles. Easy to
understand menus, text in 8 selectable languages, icons and graphics create a
friendly environment to learn about your electrical network. Ethernet gateway and
enhanced cyber security.
Highly accurate devices with global billing certications.
Applications
Cost management: Cost saving opportunities become clear once you understand
how and when your facility uses electricity. The PowerLogic PM5000 series meters
are ideal for:
bSub billing / tenant metering: allows a landlord, property management rm,
condominium association, homeowners association, or other multi-tenant property to
bill tenants for individual measured utility (electricity) usage. MID approved meters for
billing applications across Europe.
bCost allocation: allocate energy costs between different departments (HVAC,
indoor and outdoor lighting, refrigeration, etc), different parts of an industrial process
or different cost centres. Cost allocation systems can help you save money by making
changes to your operation, better maintaining your equipment, taking advantage of
pricing uctuations, and managing your demand.
Network management: Improving reliability of the electrical network is key for
success in any business. Monitoring values such as voltage levels, harmonic
distortion and voltage unbalance will help you to ensure proper operation and
maintenance of your electrical network and equipment. PowerLogic PM5000 series
meters are the perfect tool for:
bBasic Power Quality monitoring: power quality phenomena can cause
undesirable effects such as heating in transformers, capacitors, motors, generators
and misoperation of electronic equipment and protection devices.
bMin/ Max monitoring (with timestamp): understanding when electrical
parameters, such as voltage, current and power demand, reach maximum and
minimum values will give you the insight to correctly maintain your electrical network
and assure equipment will not be damaged.
bAlarming: alarms help you to be aware of any abnormal behavior on the electrical
network in the moment it happens.
bWAGES monitoring: take advantage of the input metering on PM5000 meters to
integrate measurements from 3rd party devices such as water, air, gas, electricity or
steam, meters.
Main characteristics
Easy to install
Mounts using two clips, in standard cut out for DIN 96 x 96mm, no tools required.
Compact meter with 72mm (77mm for PM5500) depth connectable up to 690 VL-L
without voltage transformers for installations compliant with category III. Optional
remote display (PM5563). Ethernet gateway functionality via RS-485 port.
Easy to operate
Intuitive navigation with self-guided, language selectable menus, six lines, four
concurrent values. Two LEDs on the meter face help the user conrm normal
operation with a green LED - heartbeat/communications indicator, and the amber
LED - customizable either for alarms or energy pulse outputs. Onboard web pages
(PM5500) show real-time and logged information, and verify communications.
Easy circuit breaker monitoring and control
The PM5300 provides two relay outputs (high performance Form A type) with
capability to command most of the circuit breaker coils directly. For Digital Inputs,
monitored switches can be wired directly to the meter without external power supply.
PM5500 series have 4 status inputs (digital) and 2 digital output (solid state) to use for
Accurate energy measurement for precise cost allocation:
PM5100 PM5300 PM5500
IEC 62053-22 (Active Energy) Class 0.5S Class 0.5S Class 0.2S
IEC 62053-23 (Reactive Energy) Class 2 Class 2 Class 1
PowerLogic PM5563 remote dispaly
PB111784
Commercial reference numbers
PM5100 METSEPM5100
PM5110 METSEPM5110
PM5111 METSEPM5111
PM5310 METSEPM5310
PM5320 METSEPM5320
PM5330 METSEPM5330
PM5331 METSEPM5331
PM5340 METSEPM5340
PM5341 METSEPM5341
PM5560 METSEPM5560
PM5561 METSEPM5561
PM5563 METSEPM5563
PM5563RD METSEPM5563RD
PM5RD METSEPM5RD
86 PLSED309005EN
Basic multi-function metering PM5000 Series
Functions and characteristics (cont.)
Direct metering of neutral current
The PM5500 has a fourth CT for measuring neutral current. In demanding IT
applications, where loads are non-linear (i.e. switching power supplies on
computers/servers), measuring neutral current is essential to avoid overload and
resulting outage. In addition, the PM5500 provides a calculated ground current
value, not available in meters with 3 CTs.
Power Quality analysis
The PM5000 offers Total Harmonic Distortion (THD/thd), Total Demand
Distortion (TDD) measurements and individual harmonics (odd) magnitudes and
angles for voltage and current:
These types of power quality parameters help to identify the source of harmonics
that can harm transformers, capacitors, generators, motors and electronic
equipment.
Load management
Peak demands with time stamping are provided. Predicted demand values can be
used in combination with alarms for basic load shedding applications.
Alarming with time stamping
A different combination of set point driven alarms and digital alarms with 1s time
stamping are available in the PM5000 family:
Alarms can be visualized as Active (the ones that have picked up and did not drop
out yet) or Historical (the ones that happened in the past). Alarms can be
programmed and combined to trigger digital outputs and mechanical relays
(PM5300).
The PM5000 series keeps an alarm log with the active and historical alarms with
date and time stamping. SMTP protocol for receiving alarm conditions via email and
text. SNTP protocol for date/time network synchronization.
Load timer
A load timer can be set to count load running hours based on a minimum current
withdraw, adjustable to monitor and advise maintenance requirements on the load.
High Performance and accuracy
IEC 61557-12 Performance measuring and monitoring devices (PMD)
Denes the performance expectation based on classes. It denes the allowable error
in the class for real and reactive power and energy, frequency, current, voltage,
power factor, voltage unbalance, voltage and current harmonics (odds), voltage
THD, current THD, as well as ratings for temperature, relative humidity, altitude,
start-up current and safety. It makes compliant meters readings comparable - they
will measure the same values when connected to the same load.
Meets IEC 61557-12 PMD/[SD|SS]/K70/0.5 for PM5100 and PM5300
Meets IEC 61557-12 PMD/[SD|SS]/K70/0.2 for PM5500
Legal billing compliance
MID compliance is compulsory for billing applications across Europe.
In addition to billing applications, for facility managers responsible for energy cost
MID means same level of quality as a billing meter.
MID ready compliance, EN50470-1/3 – Class C
Certied according to MID Directive,
Annex "B" + Annex "D" for legal
metrology relevant to active electrical
energy meters (see Annex MI-003 of MID). Can be
used for scal (legal) metrology.
MID
PM5100 PM5300 PM5500
Individual Harmonics magnitudes
up to 15th
magnitudes
up to 31st
magnitudes &
angles
up to 63rd
PM5100 PM5300 PM5500
Set point driven alarms 29 29 29
Unary 4 4 4
Digital – 2 4
Boolean / Logic – 10
Custom dened – – 5
PB111777
PB111772
PB111768
PowerLogic PM5500 meter
PowerLogic PM5300 meter
PowerLogic PM5100 meter
87
PLSED309005EN
Basic multi-function metering PM5000 Series
Functions and characteristics (cont.)
General PM5100 PM5300 PM5500
Use on LV and MV systems b
Basic metering with THD and min/max readings b
Instantaneous rms values
Current per phase, neutral and ground
(PM5500)
b
Voltage Total, per phase L-L and L-N b
Frequency b
Real, reactive, and
apparent power
Total and per phase Signed, Four Quadrant
True Power Factor Total and per phase Signed, Four Quadrant
Displacement PF Total and per phase Signed, Four Quadrant
% Unbalanced I, VL-N, VL-L b
Direct monitoring of neutral current b
Energy values*
Accumulated Active, Reactive and Apparent Energy Received/Delivered; Net and absolute; Time Counters
Demand values*
Current average Present, Last, Predicted, Peak, and Peak Date Time
Active power Present, Last, Predicted, Peak, and Peak Date Time
Reactive power Present, Last, Predicted, Peak, and Peak Date Time
Apparent power Present, Last, Predicted, Peak, and Peak Date Time
Peak demand with time stamping D/T for current and b
Demand calculation Sliding, xed and rolling block,
thermal methods
b
Synchronization of the measurement window to input,
communication command or internal clock
b
Settable Demand intervals b
Demand calculation for Pulse input (WAGES) b
Other measurements*
I/O timer b
Operating timer b
Load timer b
Alarm counters and alarm logs b
Power quality measurements
THD, thd (Total Harmonic Distortion) I, VLN, VLL per phase I,VLN, VLL
TDD (Total Demand Distortion) b
Individual harmonics (odds) 15th 31st 63rd
Neutral Current metering with ground current calculation b
Data recording
Min/max of instantaneous values, plus phase identication* b
Alarms with 1s timestamping* b
Data logging 2 selectable parameters from
kWh, kVAh, kVARh
with congurable interval and
duration (e.g. 2 parameters for
60 days at 15 minutes interval)
Up to 14 selectable parameters
with congurable interval and
duration (e.g. 6 parameters for 90
days at 15 minutes interval)
Memory capacity 256 kB 1.1 MB
Min/max log b b b
Maintenance, alarm and event logs b b
Customizable data logs b
Inputs / Outputs / Mechanical Relays
Digital inputs 24
Digital outputs 1 (kWh only) 2 (congurable)
Form A Relay outputs 2
Timestamp resolution in seconds 1
Whetting voltage b
*Stored in non-volatile memory
88 PLSED309005EN
Basic multi-function metering PM5000 Series
Functions and characteristics (cont.)
Electrical characteristics PM5100 PM5300 PM5500
Type of measurement: True rms on three-phase
(3P, 3P + N), zero blind
64 samples per cycle 128 samples per cycle
Measurement
accuracy
Active Energy 0.5% 0.2%
Reactive Energy 2% 1%
Active Power 0.5% 0.2%
Apparent Power 0.5%
Current, Phase 0.5% 0.15%
Voltage, L-N 0.5% 0.1%
Frequency 0.05%
Measurement
accuracy
compliance
Measurement accuracy IEC 61557-12 PMD/[SD|SS]/K70/0.5 IEC 61557-12 PMD/[SD|SS]/
K70/0.2
Active energy accuracy IEC 62053-22 Class 0.2 S ANSI C12.20 Class 0.5 IEC 62053-22 Class 0.2 S ANSI
C12.20 Class 0.2
Reactive energy accuracy IEC 62053-23 Class 2
Input-voltage
(up to 1.0 MV
AC max, with
voltage
transformer)
Nominal Measured Voltage range 20 V L-N / 35 V L-L to 400 V L-N /690 V L-L
absolute range 35 V L-L to 760 V L-L
20 V L-N / 20 V L-L to 400 V L-N
/690 V L-L
absolute range 20 V L-L to 828 V L-L
Impedance 5 M Ω
F nom 50 or 60 Hz ±2% 50 or 60 Hz ±10%
Input-current I nom 1 A or 5 A
Measured Amps with over range and Crest
Factor
Starting current: 5mA
Operating range: 50mA to 8.5A
Starting current: 5m A
Operating range: 50 mA to 10 A
Withstand Continuous 20A, 10s/hr 50A, 1s/hr 500A
Impedance < 0.3 mΩ
F nom 50 or 60 Hz ±2% 50 or 60 Hz ±10%
Burden <0.026VA at 8.5A < 0.024 VA at 10 A
AC control
power
Operating range 100-415 VAC +/- 10%
CAT III 300V class per IEC 61010
100-480 V AC ±10%
CAT III 600V class per IEC 61010
Burden <5 W,11 VA at 415V L-L <5W/16.0 VA at 480 V A C
Frequency 45 to 65 Hz
Ride-through time 80 mS typical at 120V AC and maximum burden.
100 mS typical at 230 V AC and maximum burden
100 mS typical at 415 V AC and maximum burden
35 ms typical at 120 V L-N and
maximum burden
129 ms typical at 230 V L-N and
maximum burden
DC control
power
Operating range 125-250 V DC ±20%
Burden 4W max at 125V DC typical 3.1W at 125 V DC, max. 5W
Ride-through time 50 mS typical at 125 V DC and maximum burden
Outputs Relay Max output frequency 0.5 Hz maximum (1 second ON / 1
second OFF - minimum times)
Switching current 250 V AC at 8.0 Amps, 25 k cycles,
resistive
30 V DC at 2.0 Amps, 75 k cycles,
resistive 30 V DC at 5.0 Amps,
12.5 k cycles, resistive
Isolation 2.5 kV rms
Digital
outputs
1 2 2
Max load voltage 40 V DC 30 V AC / 60 V DC
Max load current 20 mA 125 mA
On Resistance 50 Ω max 8 Ω
Meter constant from 1 to 9,999,999 pulses per kWh
k_h (Congurable for delivered or received or delivered+received energy for kWh or kVARh or kVAh)
Pulse width for Digital
Output
50% duty cycle
Pulse frequency for Digital
Output
25 Hz max.
Leakage current 0.03 micro Amps 1 micro Amps
Isolation 5 kV rms 2.5 kV rms
Optical outputs
Pulse width (LED) 200 micro seconds
Pulse frequency 50 Hz. max. 2.5 kHz. max
Meter constant from 1 to 9,999,999 pulses per kWh
k_h (Congurable for delivered or received or delivered+received energy for kWh or kVARh or kVAh)
89
PLSED309005EN
Basic multi-function metering PM5000 Series
Functions and characteristics (cont.)
Electrical characteristics (cont'd) PM5100 PM5300 PM5500
Status Inputs ON Voltage 18.5 to 36 V DC 30 V AC / 60 V DC max
OFF Voltage 0 to 4 V DC
Input Resistance 110 k Ω 100 k Ω
Maximum Frequency 2 Hz (T ON min = T OFF min = 250
ms)
25 Hz (T ON min = T OFF min = 20
ms)
Response Time 20 ms 10 ms
Opto Isolation 5 kV rms 2.5 kV rms
Whetting output 24 V DC/ 8mA max
Input Burden 2mA @24V DC 2 mA @ 24 V AC/DC
Mechanical characteristics
Product weight 380 g 430 g 450 g
IP degree of protection (IEC 60529) IP52 front display, IP20 meter body
Dimensions W x H x D [protrusion from cabinet] * 96 x 96 x 72mm (77mm for PM5500) (depth of meter from housing mounting ange) [13mm]
Mounting position * Vertical
Panel thickness 6 mm maximum
Environmental characteristics
Operating
temperature
Meter -25 °C to 70 °C
Display (Display functions to -25º with
reduced performance)
-25 °C to +70 °C
Storage temp. -40 °C to +85 °C
Humidity range 5 to 95 % RH at 37 °C (non-condensing)
Polution degree 2
Altitude 2000 m CAT III / 3000 m CAT II 3000 m max. CAT III
Electromagnetic compatibility**
Harmonic current emissions IEC 61000-3-2
Flicker emissions IEC 61000-3-3
Electrostatic discharge IEC 61000-4-2
Immunity to radiated elds IEC 61000-4-3
Immunity to fast transients IEC 61000-4-4
Immunity to surge IEC 61000-4-5
Conducted immunity 150kHz to 80MHz IEC 61000-4-6
Immunity to magnetic elds IEC 61000-4-8
Immunity to voltage dips IEC 61000-4-11
Radiated emissions FCC part 15, EN 55022 Class B
Conducted emissions FCC part 15, EN 55022 Class B
* PM5563 is DIN mounted
** Tests are conducted as per IEC 61557-12 (IEC 61326-1), 62052-11 and EN50470
90 PLSED309005EN
Basic multi-function metering PM5000 Series
Functions and characteristics (cont.)
Safety PM5100 PM5300 PM5500
Europe CE, as per IEC 61010-1 Ed. 3, IEC 62052-11 & IEC61557-12
U.S. and Canada cULus as per UL61010-1 (3rd Edition)
Measurement category (Voltage and Current inputs) CAT III up to 400 V L-N / 690 V L-L
Dielectric As per IEC/UL 61010-1 Ed. 3
Protective Class II, Double insulated for user accessible parts
Communication
RS 485 port Modbus RTU, Modbus ASCII
(7 or 8 bit), JBUS
2-Wire, 9600,19200 or 38400 baud, Parity - Even, Odd, None, 1 stop bit if parity Odd or Even, 2 stop bits if None;
(Optional in PM51x and PM53x)
Ethernet port: 10/100 Mbps; Modbus TCP/IP 1 Optional 2 (for daisy chain only, one IP
address)
Firmware and language le update Meter rmware update via the communication ports
Isolation 2.5 kVrms, double insulated
Human machine interface
Display type Monochrome Graphics LCD
Resolution 128 x 128
Backlight White LED
Viewable area (W x H) 67 x 62.5 mm
Keypad 4-button
Indicator Heartbeat / Comm activity Green LED
Energy pulse output / Active alarm indication (congurable) Optical, amber LED
Wavelength 590 to 635 nm
Maximum pulse rate 2.5 kHz
PM5100 PM5300 PM5500
PE86288
Features and Options PM5100 PM5110 PM5310 PM5320 PM5330 PM5340 PM5560 PM5563
Installation
Fast panel mount with integrated display b b b b b b b
Remote display (optional) b
Fast installation, DIN rail mountable b
Accuracy CI 0.5S CI 0.5S CI 0.5S CI 0.5S CI 0.5S CI 0.5S CI 0.2S CI 0.2S
Display
Backlit LCD, multilingual, bar graphs, 6 lines,
4 concurrent values
b b b b b b b
Power and energy metering
3-phase voltage, current, power, demand,
energy, frequency, power factor
b b b b b b b b
Multi-tariff 4 4 4 4 8 8
Power quality analysis
THD, thd, TDD b b b b b b b b
Harmonics, individual (odd) up to 15th 15th 31st 31st 31st 31st 63rd 63rd
I/Os and relays
I/Os 1DO 1DO 2DI/2DO 2DI/2DO 2DI/2DO 2DI/2DO 4DI/2DO 4DI/2DO
Relays 0 0 0 0 2 2 0 0
Alarms and control
Alarms 33 33 35 35 35 35 52 52
Set point response time, seconds 1 1 1 1 1 1 1 1
Single and multicondition alarms b b b b b b
Boolean alarm logic b b
Communications
PE86002
Serial ports with modbus protocol 1 1 11 1
Ethernet port with Modbus TCP protocol 112** 2**
Ethernet-to-serial gateway b b
Onboard web server with web pages b b
MID ready compliance,
EN50470-1/3, Annex B and Annex D
Class C
PM5111 PM5331 PM5341 PM5561
** 2 Ethernet ports for daisy chain, one IP address.
91
PLSED309005EN
Basic multi-function metering PM5000 Series
Dimensions and connection
PM5000 meter parts
A Menu selection buttons
B LED indicators
C Navigation or menu selections
D Maintenance and alarm
notication area
PM5000 Series meter ush mounting*
PM5000 Series meter dimensions
PB111276
PB111279
PM5100 / PM5300 meter parts
E Relay output (PM5300 only)
F Voltage inputs
G Control power
H Current inputs
I Status inputs/digital outputs
J Communications port: Ethernet
(PM5300 only) or RS-485)
PM5100 / PM5300 PM5500
PM5500 meter parts
E Voltage inputs
F RS-485 comms
G Digital inputs
H Current inputs
I Digital outputs
J Ethernet ports
K Control power
PM5500
** PM5563 is DIN mounted
PB111281
PB111282
PB111278
PB111277
Remote display connection
Remote display dimensions
PB111283
PM5000 Series meter parts
PM5000 Series remote display dimensions
PM5100 PM5300 PM5500
PE86288
Features and Options PM5100 PM5110 PM5310 PM5320 PM5330 PM5340 PM5560 PM5563
Installation
Fast panel mount with integrated display b b b b b b b
Remote display (optional) b
Fast installation, DIN rail mountable b
Accuracy CI 0.5S CI 0.5S CI 0.5S CI 0.5S CI 0.5S CI 0.5S CI 0.2S CI 0.2S
Display
Backlit LCD, multilingual, bar graphs, 6 lines,
4 concurrent values
b b b b b b b
Power and energy metering
3-phase voltage, current, power, demand,
energy, frequency, power factor
b b b b b b b b
Multi-tariff 4 4 4 4 8 8
Power quality analysis
THD, thd, TDD b b b b b b b b
Harmonics, individual (odd) up to 15th 15th 31st 31st 31st 31st 63rd 63rd
I/Os and relays
I/Os 1DO 1DO 2DI/2DO 2DI/2DO 2DI/2DO 2DI/2DO 4DI/2DO 4DI/2DO
Relays 0 0 0 0 2 2 0 0
Alarms and control
Alarms 33 33 35 35 35 35 52 52
Set point response time, seconds 1 1 1 1 1 1 1 1
Single and multicondition alarms b b b b b b
Boolean alarm logic b b
Communications
PE86002
Serial ports with modbus protocol 1 1 11 1
Ethernet port with Modbus TCP protocol 112** 2**
Ethernet-to-serial gateway b b
Onboard web server with web pages b b
MID ready compliance,
EN50470-1/3, Annex B and Annex D
Class C
PM5111 PM5331 PM5341 PM5561
92 PLSED309005EN
Front view of PowerLogic PM800 series meter with
integrated display.
The PowerLogic PM800 series meters offers many high-performance capabilities
needed to meter and monitor an electrical installation in a compact 96 x 96 mm unit.
All models include an easy-to-read display that presents measurements for all three
phases and neutral at the same time, an RS-485 Modbus communication port, one
digital input, one KY-type digital output, total harmonic distortion (THD) metering,
and alarming on critical conditions. Four models offer an incremental choice of
custom logging and power quality analysis capabilities. Expand any model with
eld-installable option modules that offer a choice of additional digital inputs and
outputs, analogue inputs and outputs, and Ethernet port.
Applications
bPanel instrumentation
bSub-billing, cost allocation and energy management
bRemote monitoring of an electrical installation
bPower quality analysis
bUtility bill verication, utility contract optimization and load preservation.
Characteristics
Easy to install
Mounts using two clips, with no tools required. Direct connect the voltage inputs, with
no need for potential transformers (PTs) up to 600 VAC.
Easy to operate
Intuitive navigation with self-guided, language-selectable menus.
System status at a glance
Large, anti-glare display with back-light provides summary screens with multiple
values. Bar charts graphically represent system loading and I/O.
Custom alarming with time stamping
Over 50 alarm conditions, including over or under conditions, digital input changes,
phase unbalance and more. The models PM850 and PM870 offer boolean logic that
can be used to combine up to four alarms.
Power quality analysis
The PM800 series offers an incremental range of features for troubleshooting and
preventing power quality related problems. All models offer THD metering. The
PM810 with PM810LOG option and PM820 offer individual current and voltage
harmonics readings. The PM850 and PM870 offer waveform capture (PM870 is
congurable) and power quality compliance evaluation to the international EN50160
-ITI(CBEMA)/SEMI F-47 standards. The PM870 offers voltage and current
disturbance (sag/swell) detection.
Extensive on-board memory
All models offer billing (energy and demand), maintenance, alarm and customizable
data logs, all stored in non-volatile memory (PM810 requires PM810LOG option).
ANSI 12.20 Class 0.2S and IEC 62053-22 Class 0.5S accuracy for active energy
Accurate energy measurement for sub-billing and cost allocation.
PMD-S IEC61557-12 performance standard
Meets PMD/SD/K70/0.5 and PMD/SS/K70/0.5 requirements for combined
Performance Measuring and monitoring Devices (PMD).
Trend curves and short-term forecasting
The models PM850 and PM870 offer trend logging and forecasting of energy and
demand readings to help compare load characteristics and manage energy costs.
Expandable I/O capabilities
Use the on-board or optional digital inputs for pulse counting, status/position
monitoring, demand synchronisation or control (gating) of the conditional energy
metering. Use the on-board or optional digital outputs for equipment control or
interfacing, controllable by internal alarms or externally through digital input status.
Use the optional analogue inputs and outputs for equipment monitoring or
interfacing.
Metering of other utilities (WAGES)
All models offer ve channels for demand metering of water, air, gas, electricity or
steam utilities (WAGES) through the pulse counting capabilities of the digital inputs.
Pulses from multiple inputs can be summed through a single channel.
Modular and upgradeable
All models offer easy-to-install option modules (memory, I/O and communications)
and downloadable rmware for enhanced meter capabilities.
Remote display
The optional remote display can be mounted as far as 10 m from the metering unit.
The adapter includes an additional 2- or 4-wire RS-485/RS-232 communication port.
PE86134PB101823-50
Rear view of PowerLogic PM800 series meter.
PowerLogic PM800 series meter
display screen showing bar graphs.
PE86229
PM800 series
Functions and characteristics
Intermediate metering
93
PLSED309005EN
Part Numbers
Description
Meter without display
Use the base meter unit without display to comply with voltage limitations for local regulations
when door mounting is not possible, or when meter voltage exceeds regulations, or when local
display is not required. When the meter is used without a display, conguration of the
communications port is limited to the default (address 1, 9600 baud, parity even). Requires
software to read data.
PM810 meter unit only, no display,
basic instrumentation, THD, alarming, 80 kB logging
(with PM810LOG)
PM810UMG
PM820 meter unit only, no display,
basic instrumentation, THD, alarming, 80 kB logging
PM820UMG
PM850 meter unit only, no display,
basic instrumentation, THD, alarming, 800 kB
logging, waveform capture
PM850UMG
PM870 meter unit only, no display,
basic instrumentation, THD, alarming, 800 kB
logging, congurable waveform capture and
disturbance detection.
PM870UMG
Meter with integrated display
Use the meter with integrated display for panel mounting when door space is available and when
voltage usage is within the local regulation limits.
PM810 meter with integrated display PM810MG
PM820 meter with integrated display PM820MG
PM850 meter with integrated display PM850MG
PM870 meter with integrated display PM870MG
Meter with remote display
Conveniently packaged kit consist of a base meter (810, 820, 850 or 870) with a remote display,
remote display adapter, and remote display cable 3 m (9.ft 10 inches).
PM810 meter with remote display PM810RDMG
PM820 meter with remote display PM820RDMG
PM850 meter with remote display PM850RDMG
PM870 meter with remote display PM870RDMG
Parts and accessories
Remote display adapter with remote display and
a 3 m (9 ft 10 inch) cable
Use this combination of remote display, adapter, and
3 m cable to equip a base meter unit for use with a
remote display. In addition, the display can be carried
from meter to meter, enabling you to purchase one
display for multiple meters. Each base unit meter
must be equipped with a remote display adapter
(PM8RDA).
PM8RDMG
Remote display adapter alone
When added to the front of the base unit (PM8xxU),
the adapter brings two additional communication
ports: one for the remote display and one 4-wire/2-
wire RS 485/RS 232.
PM8RDA
Part number list continued on next page.
PowerLogic PM800 series meter without display.
PowerLogic PM800 series meter with remote
display.
Remote display adapter with display and cable.
Remote display adaptor alone.
PB101819 -32 PE86135 PB101822 -68 PE86134 PB101814 -36
PowerLogic PM800 series meter with integrated
display.
PM800 series
Functions and characteristics (cont.)
Intermediate metering
94 PLSED309005EN
PowerLogic PM870 with ECC module (bottom view
showing connectors and conguration switches).
ECC module (front
view)
DB119012 DB119011
ECC module (side view
showing LED
indicators).
DB119013
PowerLogic PM800 with PM8M22
and PM8M26 modules.
PB101824 -50
PowerLogic PM8M26 module.
PB1018216 -34
Part Numbers - continued
Description
Optional modules
Ethernet communication module provides a 10/100BaseTx UTP port,
an RS-485 Modbus serial master port, Ethernet-to-serial line gateway
functionality, and an embedded web server that is fully compliant with
Transparent Ready - Level 1 (TRe1) systems.
The PM8ECC supports a private host PM8ECC MIB. Use of this MIB allows
the reading of Basic Metering Data, Conguration and Status of I/Os and
Conguration and Status of Alarms, plus SNMP Trap generation in response
to any PM8 on-board alarms.
PM8ECC
2 relay outputs, 2 digital inputs PM8M22
2 relay outputs, 6 digital inputs PM8M26
2 relay outputs, 2 digital inputs, 2 analogue outputs,
2 analogue inputs
PM8M2222
PM810 optional logging module for on-board data recording, uses a
non-volatile, battery-backed internal clock
PM810LOG
RJ11 Extender kit to mount RJ11 jack in panel door
(for use with PM800, CM3000, and CM4000 series meters)
RJ11EXT
Cable for remote display adapter 1.25 m (4 ft) CAB4
Cable for remote display adapter 3 m (9 ft 10 inch) CAB12
Cable for remote display adapter 9.14 m (30 ft) CAB30
Intermediate metering PM800 series
Functions and characteristics (cont.)
95
PLSED309005EN
Selection guide PM810 PM820 PM850 PM870
Performance standard
ANSI 12.20 Class 0.2S b b b b
PMD-S IEC 61557-12 PMD/SD/K70/0.5 and PMD/SS/
K70/0.5
b b b b
General
Use on LV and HV systems b b b b
Current and voltage accuracy 0.5 %/0.2% 0.5 %/0.2% 0.5 %/0.2% 0.2 %/0.2%
Active energy accuracy (5% to 200% of load) 0.2 % 0.2 % 0.2% 0.2%
Number of samples per cycle 128 128 128 128
Instantaneous rms values
Current, voltage, frequency b b b b
Active, reactive,apparent power Total & per phase b b b b
Power factor Total & per phase b b b b
Energy values
Active, reactive, apparent energy b b b b
Congurable accumulation mode b b b b
Demand values
Current Present & max. b b b b
Active, reactive, apparent
power
Present & max. b b b b
Predicted active, reactive, apparent power b b b b
Synchronisation of the measurement window b b b b
Demand calculation modeBlock, sliding, thermal b b b b
Other measurements
Hour counter b b b b
Power quality measurements
Harmonic distortion Current & voltage b b b b
Individual harmonics Current & voltage 31 (1) 31 63 63
Waveform capture - - bb (2)
EN50160 - ITI(CBEMA)/SEMI F-47 b (4) b
Sag and swell detection - - - b
Data recording
Min/max of instantaneous values b b b b
Data logs 2 (1) 24 4
Event logs - b b b
Trending / forecasting - - b b
GPS synchronisation b (1) b b b
Alarms b b b b
Time stamping b (1) b b b
Display and I/O
White backlit LCD display b b b b
Multilingual b b b b
Digital input (standard/optional) 1/12 1/12 1/12 1/12
Digital output (standard/optional) 1 KY/4 RY 1 KY/4 RY 1 KY/4 RY 1 KY/4 RY
Analogue inputs (standard/optional) 0/4 0/4 0/4 0/4
Analogue outputs (standard/optional) 0/4 0/4 0/4 0/4
Input metering capability (number of channels) 5 5 5 5
Communication
RS 485 port 2-wire 2-wire 2-wire 2-wire
Modbus protocol b b b b
RS 232/RS 485, 2- or 4-wire Modbus RTU/
ASCII (with addition of PM8RDA module)
b b b b
Ethernet 10/100Base Tx UTP port and RS485
Modbus serial master port with PM8ECC
b b b b
Option modules selection guide
The PM800 can be tted with 2 optional modules, unless otherwise indicated (3)
PM8ECC module
10/100BaseTx UTP port, RS-485 Modbus serial master port, Ethernet to serial line gateway,
embedded web server
Input/Output modules PM8M22 PM8M26* PM8M2222
Relay outputs 2 2 2
Digital inputs 2 6 2
Analogue outputs 4-20 mA 2
Analogue inputs 0-5 Vdc or 4-20 mA 2
* Includes a 24 Vdc Power Supply that can be used to power the digital inputs
(1) With PM810LOG, battery-backed internal clock and 80 kB memory. (2) Congurable. (3) Series 800
Power Meters supports up to two option modules. When PM8M2222 & PM8ECC are mounted together
with control power>370 V AC temperature rating must be reduced to -25°C to 50°C. Same applies when
using two PM8M2222. (4) PM850 does not include sag or swell detection.
PowerLogic PM800 series connectors.
1. Control power.
2. Voltage inputs.
3. Digital input/output.
4. RS 485 port.
5. Option module connector.
6. Current inputs.
7. Mounting clips.
DB109269
PowerLogic PM800 series meter with I/O module.
Intermediate metering PM800 series
Functions and characteristics (cont.)
96 PLSED309005EN
Electrical characteristics
Type of measurement 63rd harmonic, 128 samples per cycle
Measurement accuracy standard PMD-S IEC 61557-12 compliant
Current 0.5% from 0.5 A to 10 A
Voltage 0.2% 10 V - 277 V
Power Factor +/- 0.002 from 0.500 leading to 0.500 lagging
Active Power 0.2%
Frequency +/- 0.01 Hz at 45 to 67 Hz
+/- 0.01 Hz at 350 to 450 Hz
Active Energy IEC 62053-22 Class 0.5S and
ANSI C12.20 Class 0.2S
Reactive Energy IEC 62053-23 Class 2
Data update
rate
1 s
Input-voltage
characteristics
Measured voltage 0 to 600 V AC (direct L-L)
0 to 347 V AC (direct L-N)
up to 3.2 MV AC (with external VT)
Metering over-range 1.5 Un
Impedance 5 MW
Frequency measurement range 45 to 67 Hz and 350 to 450 Hz
Input-current
characteristics
CT ratings Primary Adjustable from 5 A to 32767 A
Secondary 1 A or 5 A
Measurement input range 5 mA to 10 A AC
Permissible overload 15 A continuous
50 A for 10 seconds per hour
500 A for 1 second per hour
Impedance < 0.1 W
Load < 0.15 VA
Control Power AC 115 to 415 ±10 % V AC, 15 VA with options at
45 to 67 Hz or 350 to 450 Hz
DC 125 to 250 ±20 % V DC, 10 W with options
Ride-through time 45 ms at 120 V AC or 125 V DC
Inputs/Outputs (2)
Standard
(meter unit)
1 digital KY pulse output 6 to 220 V AC ± 10% or 3 to 250 V DC ± 10%,
100 mA max. at 25 °C, 1350 V rms isolation
1 digital input 24 to 125 V AC/DC ±10 %, < 5 mA maximum
burden, 1350 Vrms isolation
PM8M22
option
2 relay outputs (1) 6 to 240 V AC or 6 to 30 V DC
2 A rms, 5 A max. for 10 seconds per hour
2 digital inputs 19 to 30 V DC, 5 mA max. at 24 V DC
PM8M26
option
2 relay outputs (1) 6 to 240 V AC, 6 to 30 V DC
2 A rms, 5 A max. for 10 seconds per hour
6 digital inputs 20 to 150 V AC/DC, 2 mA max.
24 V internal supply 20 - 34 V DC, 10 mA max. (feeds 6 digital inputs)
PM8M2222
option
2 relay outputs (1) 6 to 240 V AC, 6 to 30 V DC
2 A rms, 5 A max. for 10 seconds per hour
2 digital inputs 20 to 150 V AC/DC, 2 mA max.
2 analogue outputs 4 to 20 mA dc into 600 ohms maximum
2 analogue inputs Adjustable from 0 to 5 V DC or 4-20 mA
Switching
frequency
(digital I/O)
Standard Input/output 25 Hz, 50 % duty cycle (20 ms ON/OFF)
PM8M22 Input/output 1 Hz, 50 % duty cycle (500 ms ON/OFF)
PM8M26 and
PM8M2222
Input 25 Hz, 50 % duty cycle (20 ms ON/OFF)
Output 1 Hz, 50 % duty cycle (500 ms ON/OFF)
Mechanical characteristics
Weight (meter with integrated display) 0.6 kg
IP degree of protection (IEC 60529) IP52 integrated display. Type 12 compliant
remote display (with gasket). IP30 meter body
Dimensions Without options 96 x 96 x 70 mm (mounting surface)
With 1 option 96 x 96 x 90 mm (mounting surface)
Environmental conditions
Operating
temperature
Meter -25 °C to +70 °C (2)
Display -10 °C to +50 °C
Storage temp. Meter + display -40 °C to +85 °C
Humidity rating 5 to 95 % RH at 40 °C (non-condensing)
Pollution degree 2
Installation category III, for distribution systems up to 347 V L-N /
600 V AC L-L
Dielectric withstand As per EN 61010, UL508
Altitude 3000 m max.
(1) Mechanical endurance: 15 million operations, Electrical endurance:25000
commutations at 2 A / 250 V AC (2) Series 800 Power Meters supports up to two
option modules. When PM82222 & PM8ECC are mounted together with control
Intermediate metering PM800 series
Functions and characteristics (cont.)
97
PLSED309005EN
Electromagnetic compatibility
Electrostatic discharge Level III (IEC 61000-4-2)
Immunity to radiated elds Level III (IEC 61000-4-3)
Immunity to fast transients Level III (IEC 61000-4-4)
Immunity to impulse waves Level III (IEC 61000-4-5)
Conducted immunity Level III (IEC 61000-4-6)
Immunity to magnetic elds Level III (IEC 61000-4-8)
Immunity to voltage dips Level III (IEC 61000-4-11)
Conducted and radiated
emissions
e industrial environment/FCC part 15 class A EN 55011
Harmonics emissions IEC 61000-3-2
Flicker emissions IEC 61000-3-3
Surge immunity IEC 61000-4-12
Surge withstand capability (SWC) ANSI C37.90.1.2002
Safety
Europe e, as per IEC 61010-1 i (1)
U.S. and Canada cULus (UL508 and CAN/CSA C22.2 No. 14-M95, Industrial
Control Equipment)
Onboard communications
RS 485 port 2-wire, up to 38400 baud, Modbus
Model-dependent characteristics
Data Logs PM810 with PM810LOG, PM820, PM850 and PM870:
- 1 billing log
- 1 customisable log
PM850 and PM870 only: 2 additional custom logs
Min./max. Worst min. and max. with phase indication for Voltages,
Currents, Voltage unbalance, and THD. Min. and max. values
for power factor (True and Displacement), power (P, Q, S) and
frequency
One event log Time stamping to 1 second
Trend curves
(PM850 and PM870 only)
Four trend curves: 1 minute, 1 hour, 1 day and 1 month. Min./
max./avg. values recorded for eight parameters:
- every second for one minute for the 1-minute curve
- every minute for one hour for the 1-hour curve
- every hour for one day for the 1-day curve
- every day for one month for the 1-month curve
Hour counter Load running time in days, hours and minutes
Energy per shift Up to three user-dened intervals per day
Available for all models (the PM810 requires the PM810LOG
module)
Forecasting
(PM850 and PM870 only)
Forecasting of the values for the trended parameters for the
next four hours and next four days
PM850 waveform capture Triggered manually or by alarm, 3-cycle, 128 samples/cycle on
6 user congurable channels
PM870 enhanced waveform
capture
From 185 cycles on 1 channel at 16 samples per cycle up to
3 cycles on 6 channels at 128 samples per cycle
Alarms Adjustable pickup and dropout setpoints and time delays,
numerous activation levels possible for a given type of alarm
Historical and active alarm screens with time stamping
Response time: 1 second
Boolean combination of four alarms is possible using
the operators NAND, AND, OR, NOR and XOR on PM850 and
PM870
Digital alarms: status change of digital inputs
Memory available for logging
and waveform capture (2)
80 kbytes in PM810 with PM810LOG and PM820
800 kbytes in PM850 and PM870
Firmware update (all models) Update via the communication ports
File download available free from www.powerlogic.com
Bar graphs (all models) Graphical representation of system performance
Display characteristics
Languages English, French, Spanish, German, Russian, Turkish and
Portuguese.
Display screen Back-lit white LCD (6 lines total, 4 concurrent values)
Dimensions Display screen viewable area 73 x 69 mm
Integrated display Overall 96 x 96 mm
Depth meter + display 69.4 mm + 17.8 mm
Remote display Overall 96 x 96 x 40 mm
Weight Meter with remote display adapter 0.81 kg
Remote display 0.23 kg
Intermediate metering PM800 series
Functions and characteristics (cont.)
98 PLSED309005EN
Intermediate metering Power Meter Series 800
Dimensions and connection
Power meter with integrated display
Dimensions
DB111765
DB111766
DB111767
Front-panel mounting (meter with integrated display)
DB111768
Spacing between units
DB111769
DB111770
99
PLSED309005EN
Intermediate metering Power Meter Series 800
Dimensions and connection (cont.)
Remote display door mounting
Flush mounting
DB111792
Surface mount
DB111793
Mounting in a Ø102 cutout (replace analogue device: ammeter, voltmeter, etc.)
DB111794
PLSED309005EN
PowerLogic PM8000 series meter.
The PowerLogic PM8000 series meter is a highly accurate, extremely reliable power
and energy meter with unmatched exibility and usability. The meter combines
accurate 3-phase energy and power measurements with data logging, power quality
analysis, alarming and I/O capabilities not typically available in such a compact
meter.
The PM8000 series meters are compliant with stringent international standards that
guarantee their metering accuracy and power quality measurements. Ideal for
industrial and critical power installations that are responsible for maintaining the
operation and protability of a facility.
Applications and benets
bMaximize prots by providing the highest output possible with the least amount of
risk to availability.
bOptimize availability and reliability of electrical systems and equipment.
bMonitor power quality (PQ) for compliance and to prevent problems.
bMeters fully supported by StruxureWare Power Monitoring Expert and
PowerSCADA Expert Software.
Main characteristics
bPrecision metering:
vIEC 61557-12 PMD Sx K70 3000m 0.2 (performance measuring and monitoring
functions).
vClass 0.2S accuracy IEC 62053-22, ANSI C12.20 Class 0.2 (active energy).
vIndustry leading Class 0.5S* accuracy for reactive energy (IEC 62053-24).
vCycle-by-cycle RMS measurements updated every ½ cycle.
vFull ‘multi-utility’ WAGES metering support.
vNet metering.
vAnti-tamper protection seals.
bPQ compliance reporting and basic PQ analysis.
vMonitors and logs parameters in support of international PQ standards,
- IEC 61000-4-30 Class S
- IEC 62586 PQI-S
- EN 50160
vGenerates onboard PQ compliance reports accessible via onboard web pages:
- Basic event summary and pass/fail reports, such as EN 50160 for power
frequency, supply voltage magnitude, supply voltage dips, short and long inter-
ruptions, temporary over voltages, voltage unbalance and harmonic voltage.
- ITIC (CBEMA) and SEMI curves, with alarm categorization to support further
analyses.
- NEMA Motor Derating curve.
- Basic meter provides EN 50160 but can be congured to provide IEEE 519.
vHarmonic analysis:
- THD on voltage and current, per phase, min/max, custom alarming.
- Individual harmonic magnitudes and angles on voltage and current, up to the
63rd harmonic.
vHigh resolution waveform capture: triggered manually or by alarm, captured
waveforms available directly from the meter via FTP in a COMTRADE format.
vDisturbance detection and capture: sag/swell on any current and voltage channel,
alarm on disturbance event, waveform capture with per-event information.
vPatented disturbance direction detection: provides indication of the captured
disturbance occurring upstream or downstream of the meter; timestamped results
provided in the event log, with degree of certainty of disturbance direction.
bUsed with StruxureWare Power Monitoring Expert software, provides detailed PQ
reporting across entire network:
vEN 50160 report.
vIEC 61000-4-30 report.
vPQ compliance summary.
vISO 50001.
vDisplay of waveforms and PQ data from all connected meters.
bOnboard data and event logging.
v512MB of standard non-volatile memory. 10 MB of standard non-volatile memory
dedicated to capture billing data, events, and waveforms.
PB113688PB113691
PB113692
PM8000 series
Functions and characteristics
Intermediate metering
PowerLogic PM8000 series meter - rear view.
*Certication pending
PowerLogic PM8000 DIN rail mounted meter.
100
PLSED309005EN
PowerLogic remote display.
PowerLogic PM8000 series meter with remote display.
PB113669 PB113671 PB113670
PowerLogic I/O module.
PM8000 series
Functions and characteristics (cont.)
Intermediate metering
vNo data gaps due to network outages or server downtime.
vMin/Max log for standard values.
v50 user-denable data logs, recording up to 16 parameters on a cycle-by-cycle or
other user denable interval.
vContinuous logging or ‘snapshot’ triggered by setpoint and stopped after dened
duration.
vTrend energy, demand and other measured parameters.
vForecasting via web pages: average, minimum and maximum for the next four
hours and next four days.
vTime-of-use in conjunction with StruxureWare software.
vEvent log: alarm conditions, metering conguration changes, and power outages,
timestamped to 1 millisecond.
bAlarming and control.
v50+ denable alarms to log critical event data, trigger waveform recording, or
perform control function.
vTrigger on any condition, with cycle-by-cycle and 1-second response time.
vCombine alarms using Boolean logic and to create alarm levels.
vAlarm notication via email text message.
vIn conjunction with StruxureWare Power Monitoring Expert, software alarms and
alarm frequency are categorized and trended for easy evaluation of worsening/
improving conditions.
bExcellent quality: ISO 9001 and ISO 14000 certied manufacturing.
Usability
bEasy installation and setup.
vPanel and DIN rail mounting options, remote display option.
vPluggable connectors.
vFree setup application simplies meter conguration.
bFront panel.
vEasy to read colour graphic display.
vSimple, intuitive menu navigation with multi-language (8) support.
bFlexible remote communications.
vMultiple simultaneously operating communication ports and protocols allow
interfacing with other automation systems; (e.g. waveforms, alarms, billing data,
etc.) can be uploaded for viewing/analysis while other systems access real-time
information.
vSupports Modbus, ION, DNP3, IEC 61850.
vDual port Ethernet: 10/100base-TX; daisy-chaining capability removes need for
additional switches.
vCreate redundant network loop using Rapid Spanning Tree Protocol (RSTP) and
managed Ethernet switches.
vCustomize TCP/IP port numbers enable/disable individual ports.
vRS-485 2-wire connection, up to 115200 baud, Modbus RTU and ION protocols,
DNP3 is also supported via RS-485.
vEthernet to serial gateway with Modbus Master functionality, connecting to 31
downstream serial Modbus devices. Also supports Modbus Mastering over TCP/
IP (Ethernet) network.
vFull function web server with factory and customizable pages to access real-time
and PQ compliance data.
vPush historical data via email.
vAdvanced security: Up to 16 congurable user accounts.
bTime synchronization via:
vGPS clock (RS485) or IRIG-B (digital input) to +/- 1 millisecond.
vAlso supports Network Time Protocol (NTP/SNTP) and time set function from
StruxureWare software server.
Adaptability
bION™ frameworks allow customizable, scalable applications, object-oriented
programming, compartmentalizes functions, and increases exibility and
adaptability.
101
PLSED309005EN
PB113686
Intermediate metering PM8000 series
Functions and characteristics (cont.)
vApplications include: access and aggregate data from Modbus devices on serial
port or across the network (Modbus TCP/IP), logging and/or processing data by
totalizing, unit conversion or other calculations, applying complex logic for
alarming or control operations, data visualization via web pages.
Standard meter I/O
b3 digital status/counter inputs.
b1 KY (form A) energy pulse output for interfacing with other systems.
Modular I/O options
bOptional expansion modules (up to 4 per meter) add digital/analogue I/O.
Option modules include:
bDigital module
v6 digital status/counter inputs.
v2 Form C relay outputs, 250V, 8A.
bAnalogue module
v4 analogue inputs (4-20mA; 0-30V).
v2 analogue outputs (4-20mA; 0-10V) for interfacing with building management
sensors and systems.
Reference numbers
Meter Description
METSEPM8240 DIN96 panel mount meter
METSEPM8243 DIN rail mount meter
METSEPM8244 DIN rail mount meter with remote display
Accessories Description
METSEPM89RD96 Remote display, 3 metre cable, mounting hardware for
30mm hole (nut & centering pin), mounting hardware
for DIN96 cutout (92x92mm) adapter plate
METSEPM8000SK Terminal covers for utility sealing
METSEPMAK Adapters for mounting meter and remote display back
to back & ANSI 4”, 0.3 metre (1 ft.) Ethernet cable
METSECAB10 Display Cable, 10 metres
METSEPM89M2600 Digital I/O module (6 digital inputs & 2 relay outputs)
METSEPM89M0024 Analogue I/O module (4 analogue inputs & 2 analogue
outputs)
PowerLogic PM8000 series meter with I/O modules.
102
PLSED309005EN
Intermediate metering PM8000 series
Functions and characteristics (cont.)
PB113696
PowerLogic™ PM8000 bottom view DIN mounting.
Features guide PM8000
General
Use on LV and MV systems b
Current accuracy (5A Nominal) 0.1 % reading
Voltage accuracy (57 V LN/100 V LL to 400 V LN/690 V LL) 0.1 % reading
Active energy accuracy 0.2 %
Number of samples/cycle or sample frequency 256
Instantaneous rms values
Current, voltage, frequency b
Active, reactive, apparent power Total and per phase b
Power factor Total and per phase b
Current measurement range (autoranging) 0.05 - 10A
Energy values
Active, reactive, apparent energy b
Settable accumulation modes b
Demand values
Current Present and max. values b
Active, reactive, apparent power Present and max. values b
Predicted active, reactive, apparent power b
Synchronisation of the measurement window b
Setting of calculation mode Block, sliding b
Power quality measurements
Harmonic distortion Current and voltage b
Individual harmonics Via front panel and web page 63
Via StruxureWare software 127
Waveform capture b
Detection of voltage swells and sags b
Fast acquisition 1/2 cycle data b
EN 50160 compliance checking b
Customizable data outputs (using logic and math functions) b
Data recording
Min/max of instantaneous values b
Data logs b
Event logs b
Trending/forecasting b
SER (Sequence of event recording) b
Time stamping b
GPS synchronisation (+/- 1 ms) b
Memory (in Mbytes) 512
Display and I/O
Front panel display b
Wiring self-test b
Pulse output 1
Digital or analogue inputs(max) 27 digital
16 analogue
Digital or analogue outputs (max, including pulse output) 1 digital
8 relay
8 analogue
Communication
RS 485 port 1
Ethernet port 2
Serial port (Modbus, ION, DNP3) b
Ethernet port (Modbus/TCP, ION TCP, DNP3 TCP, IEC 61850 (2))b
Ethernet gateway b
Alarm notication via email b
HTTP web server b
SNMP with custom MIB and traps for alarms b
SMTP email b
NTP time synchronization b
FTP le transfer b
103
PLSED309005EN
Intermediate metering PM8000 series
Functions and characteristics (cont.)
Electrical characteristics PM8000
Type of measurement True rms to 256 samples per cycle
Measurement
accuracy
Current & voltage Class 0.2 as per IEC 61557-12
Active Power Class 0.2 as per IEC 61557-12
Power factor Class 0.5 as per IEC 61557-12
Frequency Class 0.2 as per IEC 61557-12
Active energy Class 0.2S IEC 62053-22 (In=5A)
Class 0.2 IEC 61557-12, ANSI C12.20 Class 0.2
Reactive Energy Class 0.5S IEC 62053-24*
Data update rate 1/2 cycle or 1 second
Input-voltage
characteristics
Specied accuracy
voltage
57 VLN/100 VLL to 400 VLN/690 VLL
Impedance 5 MW per phase
Specied accuracy
frequency
- Frequency
42 to 69Hz
(50/60Hz nominal)
Limit range of
operation
- frequency
20 to 450Hz
Input-current
characteristics
Rated nominal
current
1A (0.5S), 5A (0.2S) , 10A (0.2 ANSI)
Specied accuracy
current range
Starting Current: 5mA
Accurate Range: 50mA - 10A
Permissible
overload
200 A rms for 0.5s, non-recurring
Impedance 0.0003 W per phase
Burden 0.024 VA at 10A
Power supply AC 90-415 V AC ±10% (50/60Hz ± 10%)
DC 120-300 V DC ±10%
Ride-through time 100 ms (6 cycles at 60 Hz) min., any condition
200 ms (12 cycles at 60 Hz) typ., 120 V AC
500 ms (30 cycles at 60 Hz) typ., 415 V AC
Burden Meter Only: 18 VA max at 415V AC, 6W at 300V DC
Fully optioned meter: 36 VA max at 415V AC, 17W at
300V DC.
Input/outputs Meter Base Only 3 form A digital inputs (30V AC/60 V DC)
1 form A (KY) solid state digital output (30V AC/60 V DC,
75mA).
Optional Digital - 6 form A digital inputs (30V AC / 60V DC) wetted +
2 form C relay outputs (250VAC, 8A)
Analogue - 4 analogue inputs (4-20mA, 0-30Vdc) + 2
analogue outputs (4-20mA, 0-10Vdc).
Mechanical characteristics
Weight Integrated Display Model 0.581 kg
DIN rail mounted Model 0.528 kg
IO modules 0.140 kg
Remote display 0.300 kg
IP degree of protection IP 54, UL type 12: Panel mount and Remote display,
front.
IP 30: Panel mount rear, DIN rail mount, I/O modules.
Dimensions Panel mount
model
96 x 96 x 77.5 mm
DIN model 90.5 x 90.5 x 90.8 mm
Remote display 96 x 96 x 27 mm
IO modules 90.5 x 90.5 x 22 mm
Environmental conditions
Operating temperature -25ºC to +70ºC
Remote Display Unit -25ºC to +60ºC
Storage temperature -40ºC to +85ºC
Humidity rating 5% to 95% non-condensing
Installation category III
Operating altitude (maximum) 3000m above sea level
104
PLSED309005EN
Intermediate metering PM8000 series
Functions and characteristics (cont.)
Electromagnetic compatibility
Product standards IEC 62052-11 and IEC 61326-1
Immunity to electrostatic discharge IEC 61000-4-2
Immunity to radiated elds IEC 61000-4-3
Immunity to fast transients IEC 61000-4-4
Immunity to surges IEC 61000-4-5
Immunity to conducted disturbances IEC 61000-4-6
Immunity to power frequency
magnetic elds
IEC 61000-4-8
Immunity to conducted disturbances,
2-150kHz
CLC/TR 50579
Immunity to voltage dips &
interruptions
IEC 61000-4-11
Immunity to ring waves IEC 61000-4-12
Conducted and radiated emissions EN 55022, EN 55011, FCC part 15, ICES-003
Surge withstand Capability (SWC) IEEE C37.90.1
Safety
Safety Construction IEC/EN 61010-1 ed.3, CAT III, 400 VLN / 690 V LL
UL 61010-1 ed.3 and CSA-C22.2 No. 61010-1 ed.3, CAT
III, 347 V LN / 600 V LL
IEC/EN 62052-11, protective class II
Communication (1)
Ethernet to serial line gateway Communicates directly with up to 32 unit load ION slave
devices.
Web server Customisable pages, new page creation capabilities,
HTML/XML compatible.
Serial port RS 485 Baud rates of 2400 to 115200, pluggable screw terminal
connector.
Ethernet port(s) 2x 10/100Base-TX, RJ45 connector (UTP).
Protocol Modbus, ION, DNP3, IEC 61850, HTTP, FTP, SNMP, SMTP,
DPWS, RSTP, NTP, SNTP, GPS protocols.
Firmware characteristics
High-speed data recording Down to 1/2 cycle interval burst recording, stores detailed
characteristics of disturbances or outages. Trigger
recording by a user-dened setpoint, or from external
equipment.
Harmonic distortion Up to 63rd harmonic (127th via StruxureWare software)
for all voltage and current inputs.
Sag/swell detection Analyse severity/potential impact of sags and swells:
magnitude and duration data suitable for plotting on
voltage tolerance curves per phase triggers for waveform
recording, control.
Disturbance direction detection Determine the location of a disturbance more quickly and
accurately by determining the direction of the disturbance
relative to the meter. Analysis results are captured in the
event log, along with a timestamp and condence level
indicating level of certainty.
Instantaneous High accuracy of standard speed (1s) and high-speed
(1/2 cycle) measurements, including true rms per phase
and total for:
voltage, current, active power (kW),reactive power (kvar),
apparent power (kVA), power factor, frequency, voltage
and current unbalance, phase reversal.
Load proling Channel assignments (800 channels via 50 data
recorders) congurable for any measurable parameter,
including historical trend recording of energy, demand,
voltage, current, power quality, or any measured
parameter. Trigger recorders based on time interval,
calendar schedule, alarm/event condition, or manually.
Trend curves Historical trends and future forecasts to better manage
demand, circuit loading, and other parameters. Provides
average, min, max and standard deviation every hour for
last 24 hours, every day for last month, every week for last
8 weeks and every month for last 12 months.
Waveform captures Simultaneous capture of all voltage and current channels
sub-cycle disturbance capture, maximum cycles is
100,000 (16 samples/cycle x 96 cycles, 10MBytes
memory), max 256 samples/cycle.
Alarms Threshold alarms: adjustable pickup and dropout setpoints
and time delays, numerous activation levels possible for a
given type of alarm, user-dened or automatic alarm
threshold settings, user-dened priority levels (optional
automatic alarm setting).
(1) All the communication ports may be used simultaneously.
105
PLSED309005EN
Firmware characteristics (cont.)
Advanced security Up to 16 users with unique access rights. Perform resets,
time sync, or meter congurations based on user
privileges.
Memory 512MB (10MB for programming and interval logging).
Firmware update Update via the communication ports.
Display characteristics
Integrated or Remote display 320x240 (1/4 VGA) Colour LCD, congurable screens , 5
buttons and 2 LED indicators (alarm and meter status).
Languages English, French, Spanish, Russian, Portugese,German,
Italian, Chinese.
Notations IEC, IEEE.
The HMI menu includes
Alarms Active alarms, historic alarms.
Basic Reading Voltage, current, frequency, power summary.
Power Power summary, demand, power factor.
Energy Energy total, delivered, received.
Events Timestamped verbose event log.
Power Quality EN 50160, harmonics, phasor diagrams.
Inputs/Outputs Digital inputs, digital outputs, analogue inputs, analogue
outputs.
Nameplate Model, serial and FW version.
Custom Screens Build your own metrics.
Setup Menu Meter setup, communications setup, display setup, date/
time/clock setup, alarm setup, language setup, time of
use setup, resets, password setup.
Intermediate metering PM8000 series
Functions and characteristics (cont.)
106
107
PLSED309005EN
ION7550 / ION7650
Functions and characteristics
Advanced metering
Used at key distribution points and sensitive loads, PowerLogic™ ION7550 and
ION7650 meters offer unmatched functionality including advanced power quality
analysis coupled with revenue accuracy, multiple communications options, web
compatibility, and control capabilities. Customise metering or analysis functions at
your work station, without hard wiring. Just link drag-and-drop icons or select default
settings. Integrate the meters with StruxureWare Power Monitoring software or share
data with SCADA systems via multiple communication channels and protocols.
Applications
Reduce energy costs.
Increase equipment utilisation.
Comply with environmental and regulatory requirements.
Improve power quality and reliability.
Improve customer satisfaction and retention.
Monitor and control equipment.
Integrated utility metering.
Allocate or sub-bill energy costs to departments, processes or tenants.
Main characteristics
Anticipate, diagnose and verify to increase efciency
Reveal energy inefciencies or waste and optimise equipment operation to increase
efciency. Isolate reliability risks, diagnose power-related equipment issues and
verify reliable operation.
Summarise power quality, set targets, measure and verify results
Consolidate all the power quality characteristics into a single trendable index.
Benchmark power quality and reliability and compare against standards, or compare
facilities or processes.
Easy to use, multilingual, IEC/IEEE congureable display
Bright LCD display with adjustable contrast. Screen-based menu system to congure
meter settings including IEC or IEEE notations. Multilingual support for English,
French, Spanish and Russian. 12/24 hour clock support in multiple formats.
Modbus Master functionality
Read information from downstream Modbus devices and view it via the front panel or
store in memory until you upload to the system level.
IEC 61850 protocol
Increase interoperability and decrease engineering time using standard protocol.
Gateway functionality
Access through the meter’s Ethernet port (EtherGate) or telephone network
(ModemGate) to Modbus communicating devices connected to meter serial ports.
Detect and capture transients as short as 20µs at 50Hz (17µs at 60 Hz)
Identify problems due to short disturbances, e.g. switching of capacitors, etc.
Power quality compliance monitoring
Monitor compliance with international quality-of-supply standards (IEC 61000-4-30
class A ed. 2(1), EN50160(1), IEC 61000-4-7(1), IEC 61000-4-15(1), IEEE 519, IEEE 1159,
and CBEMA/ITIC). Evaluate icker based on IEC 61000-4-15(1) and IEEE 1453(1).
Detect waveshape changes
Detection of phase switching phenomena (for example during the transfer of a high-
speed static switch) not detected by classical threshold-based alarms.
Record ultra-fast electrical parameters every 100 ms or every cycle
Preventive maintenance: acquisition of a motor startup curve, etc.
Trend curves and short-term forecasting
Rapid trending and forecasting of upcoming values for better decision making.
Disturbance direction detection
Determine disturbance location and direction relative to the meter. Results captured
in the event log, along with a timestamp and certainty level.
Alarm setpoint learning
The meter analyses the circuit and recommends alarm setpoints to minimise
nuisance or missed alarms.
Notify alarms via email
High-priority alarms sent directly to the user’s PC. Instant notication of power quality
events by email.(1)
Part numbers
ION7550 / ION7650
ION7550 M7550
ION7650 M7650
Remote display M765RD
Remote display w/power supply M765RDPS
(1) ION7650 only
PowerLogic™ ION7650
108 PLSED309005EN
PE86288
PowerLogic™ ION7550 / ION7650 rear view.
1 Current/voltage inputs
2 Digital inputs
3 Analogue inputs
4 Analogue outputs
5 Communications card
6 Power supply
7 Form C digital outputs
8 Digital inputs
9 Form A digital outputs
Selection guide ION7550 ION7650
General
Use on LV and HV systems b b
Current accuracy (1A to 5A) 0.1 % reading 0.1 % reading
Voltage accuracy (57V to 288V) 0.1 % reading 0.1 % reading
Energy accuracy 0.2 % 0.2 %
Nbr of samples/cycle or sample frequency 256 1024
Instantaneous rms values
Current, voltage, frequency b b
Active, reactive, apparent power Total and per phase b b
Power factor Total and per phase b b
Current measurement range (autoranging) 0.01 - 20A 0.01 - 20A
Energy values
Active, reactive, apparent energy b b
Settable accumulation modes b b
Demand values
Current Present and max. values b b
Active, reactive, apparent power Present and max. values b b
Predicted active, reactive, apparent power b b
Synchronisation of the measurement window b b
Setting of calculation mode Block, sliding b b
Power quality measurements
Harmonic distortion Current and voltage b b
Individual harmonics Via front panel 63 63
Via ION Enterprise 127 511
Waveform capture b b
Detection of voltage swells and sags b b
Detection and capture of transients -20 µs(1)
EN50160 icker -b
Fast acquisition of 100 ms or 20 ms data b b
EN50160 compliance checking -b
Programmable (logic and math functions) b b
Data recording
Min/max of instantaneous values b b
Data logs b b
Event logs b b
Trending/forecasting b b
SER (Sequence of event recording) b b
Time stamping b b
GPS synchronisation (1 ms) b b
Memory (in Mbytes) 10 10
Display and I/O
PE86002
Front panel display b b
Optional colour touchscreen remote display b b
Wiring self-test b b
Pulse output 1 1
Digital or analogue inputs(max) 20 20
Digital or analogue outputs (max, including pulse output) 12 12
Communication
RS 485 port 1 1
RS 485 / RS 232 port 1 1
Optical port 1 1
Modbus protocol b b
IEC 61850 protocol b b
Ethernet port (Modbus/TCP/IP protocol, IEC 61850 (2))1 1
Ethernet gateway (EtherGate) 1 1
Alarms (optional automatic alarm setting b b
Disturbance waveform capture and power quality report Alarm notication via email b b
HTML web page server (WebMeter) b b
Internal modem 1 1
Modem gateway (ModemGate) b b
DNP 3.0 through serial, modem, and I/R ports b b
(1) For 50 Hz line frequency; 17µs for 60 Hz line frequency.
ION7550 / ION7650
Functions and characteristics (cont.)
Advanced metering
1
1
234
6
78
5
9
109
PLSED309005EN
PowerLogic ION7650
Electrical characteristics
PE86126
Type of measurement True rms to 1024 samples per cycle (ION7650)
Measurement
accuracy
Current and voltage ±0.01% of reading + ±0.025% of full scale
Power ±0.075% of reading + ±0.025% of full scale
Frequency ±0.005Hz
Power factor ±0.002 from 0.5 leading to 0.5 lagging
Energy: IEC62053-22 0,2S, 1A and 5A
Data update rate 1/2 cycle or 1 second
Input-voltage
characteristics
Measurement range Autoranging 57V through 347V LN / 600V LL
Impedance 5 MW/phase (phase - Vref)
Frequency measurement
range
42 to 69Hz
Input-current
characteristics
Rated nominal current 1A, 2A, 5A, 10A
Measurement range 0.005 - 20 A autoranging (standard range)
0.001 - 10 A autoranging (optional range)
Permissible overload 500 A rms for 1 s, non-recurring (5A)
50 A rms for 1s, non-recurring (1A)
Impedance 0.002 W per phase (5A)
0.015 W per phase (1A)
Burden 0.05 VA per phase (5 A)
0.015 VA per phase (1 A)
Power supply AC 85-240 V AC ±10% (47-63 Hz)
DC 110-300 V DC ±10%
DC low voltage (optional) 20-60 V DC ±10%
Ride-through time 100 ms (6 cycles at 60 Hz) min.
Burden Standard: typical 20 VA, max 45 VA
Low voltage DC: typical 15 VA, max 20 VA
Power supply for remote display 24 VDC, burden 6.
Input/outputs(1)
(includes Event
Priority)
Standard 8 digital inputs (120 V DC)
3 relay outputs (250 V AC / 30 V DC)
4 digital outputs (solid state)
Optional 8 additional digital inputs
4 analogue outputs, and/or 4 analogue inputs
Mechanical characteristics
Weight 1.9 kg
IP degree of protection (IEC 60529) Integrated display, front: IP 50; back: IP 30
Transducer unit (no display): IP 30; remote
display: IP65
Dimensions Standard model 192 x 192 x 159 mm
TRAN model 235.5 x 216.3 x 133.1 mm
Environmental conditions
Operating
temperature
Standard power supply -20 to +70 ºC
Low voltage DC supply -20 to +50 ºC
Integral display range -20 to +60 ºC
Remote display range 0 to +50 ºC
Storage
temperature
Display, TRAN
Remote display
-40 to +85 ºC
-20 to +60 ºC
Humidity rating 5 - 95% non-condensing, remote display 0 - 85%
Installation category III (2000m above sea level)
Dielectric withstand As per EN 61010-1, IEC 62051-22A(2)
Electromagnetic compatibility
Electrostatic discharge IEC 61000-4-2
Immunity to radiated elds IEC 61000-4-3
Immunity to fast transients IEC 61000-4-4
Immunity to surges IEC 61000-4-5
Conducted and radiated emissions CISPR 22
Safety
Europe IEC 61010-1
Communication
RS 232/485 port (1) Up to 115,200 bauds (57,600 bauds for RS
485), ION, DNP 3.0, Modbus, GPS, EtherGate,
ModemGate, Modbus Master
RS 485 port (1) Up to 57,600 bauds, ION, DNP 3.0, Modbus,
GPS, EtherGate, ModemGate, Modbus Master
Infrared port(1) ANSI type 2, up to 19,200 bauds, ION, Modbus,
DNP 3.0
Ethernet port 10Base-T/100Base-TX, RJ45 connector, 100 m
Fibre-optic Ethernet link
(8 simultaneous connections supported)
100 Base FX, SC duplex connector, 1300 nm,
FO multimode with gradient index 62.5/125 µm
or 50/125 µm, 2000 m link
(1) Consult the ION7550 / ION7650 installation guide for complete specications.
(2) IEC 62051-22B with serial ports only.
ION7550 / ION7650
Functions and characteristics (cont.)
Advanced metering
110 PLSED309005EN
PE86004
Communication (cont.)
Protocol ION, Modbus, TCP/IP, DNP 3.0, Telnet, IEC 61850(2)
EtherGate Communicates directly with up to 62 slave devices via
available serial ports
ModemGate Communicates directly with up to 31 slave devices
Ethernet port 10Base-T/100Base-TX, RJ45 connector, 100 m link
Supported web protocols SNMP, SMTP, FTP
WebMeter 5 customisable pages, new page creation capabilities,
HTML/XML compatible
Firmware characteristics
High-speed data recording Down to 5ms interval burst recording, stores detailed
characteristics of disturbances or outages. Trigger
recording by a user-dened setpoint, or from external
equipment.
Harmonic distortion Up to 63rd harmonic (511th for ION7650 via ION
Enterprise software) for all voltage and current inputs
Sag/swell detection Analyse severity/potential impact of sags and swells:
magnitude and duration data suitable for plotting on
voltage tolerance curves
per phase triggers for waveform recording, control
Disturbance direction detection Determine the location of a disturbance more quickly
and accurately by determining the direction of the
disturbance relative to the meter. Analysis results are
captured in the event log, along with a timestamp and
condence level indicating level of certainty.
Instantaneous High accuracy (1s) or high-speed (1/2 cycle)
measurements, including true rms per phase / total for:
voltage and current
active power (kW) and reactive power (kvar)
apparent power (kVA)
power factor and frequency
voltage and current unbalance
phase reversal
Load proling Channel assignments (800 channels via 50 data
recorders) congurable for any measurable parameter,
including historical trend recording of energy, demand,
voltage, current, power quality, or any measured
parameter. Trigger recorders based on time interval,
calendar schedule, alarm/event condition, or manually.
Trend curves Access historical data at the front panel. Display, trend
and continuously update historical data with date and
timestamps for up to four parameters simultaneously.
Waveform captures Simultaneous capture of all voltage and current channels
sub-cycle disturbance capture
maximum cycles is 214,000 (16 samples/cycle x 96
cycles, 10Mbytes memory)
256 samples/cycle (ION7550)
512 samples/cycle standard, 1024 samples/cycle optional
(ION7650)
COMTRADE waveform format available direct from the
meter (Ethernet port option only)
PE86005
Alarms Threshold alarms:
adjustable pickup and dropout setpoints and time delays,
numerous activation levels possible for a given type of
alarm
user-dened priority levels
boolean combination of alarms is possible using the
operators NAND, OR, NOR and XOR
Advanced security Up to 16 users with unique access rights. Perform resets,
time syncs, or meter congurations on user privileges
Transformer correction Correct for phase / magnitude inaccuracies in current
transformers (CTs), potential transformers (PTs)
Memory 5 to 10 Mbytes (specied at time of order)
Firmware update Update via the communication ports
Display characteristics
Integrated display Back lit LCD, congurable screens
Remote display Colour TFT, congurable screens
Integrated display languages English, French, Spanish, Russian
Remote display languages English, French, Spanish
Example showing instantaneous values and alarm. Notations IEC, IEEE
(1) All the communication ports may be used simultaneously.
(2) Only available with 5MB memory meters.
ION7550 / ION7650
Functions and characteristics (cont.)
Advanced metering
111
PLSED309005EN
ION7550 / ION7650
Functions and characteristics (cont.)
Advanced metering
Part numbers
Example ION7650 product part number.
Item Code Description
PE86020
1 Model Advanced meter with wide-range voltage inputs (57-347V
line-neutral or 100-600V line-line), transient detection, data
and waveform recording, IEC 61000-4-30 Class A & EN50160.
Supports ION, IEC 61850 (only for meters with 5MB memory and
Ethernet comm card) Modbus-RTU, and DNP 3.0.
Advanced meter with wide-range voltage inputs (57-347V
line-neutral or 100-600V line-line), sag/swell detection, data and
waveform recording. Supports ION, IEC 61850 (only for meters
with 5MB memory and Ethernet comm card) Modbus-RTU, and
DNP 3.0.
2Form Factor A0 Integrated display with front optical port, 5 MB logging memory,
and 512 samples/cycle resolution (ION7650) or 256 samples/
cycle (ION7550).
A1 ION7650 only. Integrated display with front optical port, 5 MB
logging memory, and 1024 samples/cycle resolution.
1 Model.
2 Form factor.
3 Current Inputs.
4 Voltage Inputs.
5 Power supply.
6 System frequency.
7 Communications.
8 Inputs/outputs.
9 Security.
10 Special order.
B0 Integrated display with front optical port, 10 MB logging memory,
and 512 samples/cycle resolution (ION7650) or 256 samples/
cycle (ION7550).
B1 ION7650 only. Integrated display with front optical port, 10 MB
logging memory, and 1024 samples/cycle resolution.
T0 Transducer (no display) version, with 5 MB logging memory, and
512 samples/cycle resolution (ION7650) or 256 samples/cycle
(ION7550).
T1 ION7650 only. Transducer (no display) version, with 5 MB
logging memory, and 1024 samples/cycle resolution.
U0 Transducer (no display) version, with 10 MB logging memory,
and 512 samples/cycle resolution (ION7650) or 256 samples/
cycle (ION7550).
U1 ION7650 only. Transducer (no display) version, with 10 MB
logging memory, and 1024 samples/cycle resolution.
3Current Inputs C5 Amp nominal, 20 Amp full scale current input
E1 Amp nominal, 10 Amp full scale current input
FCurrent Probe Inputs (for 0-1 VAC current probes; sold
GCurrent Probe Inputs with three Universal Technic 10A clamp on
CTs; meets IEC 1036 accuracy
4Voltage Inputs 057 to 347 VAC line-to-neutral / 100 to 600 VAC line-to-line
5Power Supply BStandard power supply (85-240 VAC, ±10%/47-63 Hz / 110-300
VDC, ±10%)
CLow voltage DC power supply (20-60 VDC)
6 System
Frequency
5Calibrated for 50 Hz systems
6Calibrated for 60 Hz systems
7 Communications A0 Standard communications (1 RS-232/RS-485 port, 1 RS-485 port).
Integrated display models include 1 ANSI Type 2 optical port.
C1 Standard communications plus 10Base-T/100Base-TX Ethernet
(RJ45), 56k universal internal modem (RJ11). Ethernet and
modem gateway functions each use a serial communications
D7 Standard communications plus 10Base-T/100Base-TX Ethernet
(RJ45) and 100BaseFX Ethernet Fiber, 56k universal internal
modem (RJ11). Ethernet/modem gateway uses serial port.
E0 Standard communications plus 10Base-T/100Base-TX (RJ45).
Ethernet gateway function uses a serial communications port.
F1 Standard communications plus 10Base-T/100Base-TX Ethernet
(RJ45) and 100Base-FX (SC male Fiber Optic connection).
Ethernet gateway function uses a serial port.
M1 Standard communications plus 56k universal internal modem
(RJ11). Modem gateway function uses a serial port.
8 I/O A Standard I/O (8 digital ins, 3 Form C relays, 4 Form A solid-state
EStandard I/O plus Expansion I/O card (8 additional digital inputs &
four 0 to 20 mA analogue inputs)
KStandard I/O plus Expansion I/O card (8 additional digital inputs &
four 0 to 20 mA analogue outputs)
NStandard I/O plus Expansion I/O card (8 additional digital inputs &
four 0 to 20 mA analogue inputs and four 0 to 20 mA outputs)
PStandard I/O plus Expansion I/O card (8 additional digital inputs &
four 0 to 1 analogue inputs and four -1 to 1 mA analogue outputs)
9 Security 0 Password protected, no hardware lock
1Password protected, hardware lockable (enabled/disabled via
jumper on comm card)
6Password protected with security lock enabled, terminal cover and
UK OFGEM labels
M
112 PLSED309005EN
ION7550 / ION7650
Functions and characteristics (cont.)
Part numbers (cont’d)
Item Code Description
10 Other options A None
CTropicalisation treatment applied
EION7650 only. EN50160 compliance monitoring,
IEC61000-4-30 Class A measureme6nts
FION7650 only. EN50160 compliance monitoring, with
tropicalisation treatment, IEC61000-4-30 Class A
measurements
Communications Card (1)
PE86021
Example order code. Use this group of codes when ordering
the PowerLogic™ ION7550/7650 communications or I/O
cards.
Item Code Description
1 Comm card P765C ION7550 / ION7650 communication card for eld retrot
installations
2 Type A0 Standard communications (1 RS-232/RS-485 port, 1 RS-485
port). Front optical port support for meters with integrated
display.
C1 Standard communications plus 10Base-T/100Base-TX
Ethernet (RJ45), 56k universal internal modem (RJ11; the
modem port is shared with the front optical port). Ethernet and
modem gateway functions each use a serial communications
port. IEC 61850 protocol (depending on rmware version).
1 Communications or I/O card.
2 Type
3 Special order.
D7 Standard communications plus 10Base-T/100Base-TX
Ethernet, 100BaseFX Ethernet Fiber, 56k universal internal
modem (RJ11; the modem port is shared with the front optical
port).
Ethernet and modem gateway functions each use a serial
communications port.IEC 61850 protocol (depending on
rmware version).
E0 Standard communications plus 10Base-T/100Base-
TX Ethernet. Ethernet gateway function uses a serial
communications port. IEC 61850 protocol (depending on
rmware version).
F1 Standard communications plus 10Base-T/100Base-TX
Ethernet, 100BaseFX Ethernet Fiber (SC male Fiber Optic
connection). Ethernet gateway function uses a serial
communications port. IEC 61850 protocol (depending on
rmware version).
M1 Standard communications plus 56k universal internal modem
(RJ11; the modem port is shared with the front optical port).
Modem gateway function uses a serial communications port.
3Special order A None
CTropicalization treatment applied
Input/Output expansion card
Item Code Description
I/O card P760A Expansion I/O for eld retrot installations.
Type D Expansion I/O card with eight digital inputs, four 0 to 1 mA
analogue inputs
EExpansion I/O card with eight digital inputs, four 0 to 20 mA
analogue inputs
HExpansion I/O card with eight digital inputs, four -1 to 1 mA
analogue outputs
KExpansion I/O card with eight digital inputs, four 0 to 20 mA
analogue outputs
NExpansion I/O card with eight digital inputs, four 0 to 20 mA
analogue inputs & four 0 to 20 mA outputs
PExpansion I/O card with eight digital inputs, four 0 to 1 analogue
inputs and four -1 to 1 mA analogue outputs
Special Order A None
PE86019
CTropicalization treatment applied
ION7550 / ION7650 related items
Code Description
ADPT-37XX-7500 Adapter plate to t meter into a 3710 or 3720 ACM panel cutout
TERMCVR-7500 Terminal strip cover for the ION7550 or ION7650
M1UB10A1V-10A 10 A / 1 VAC Universal Technic Clamp On Current Probe
M765RD Colour touchscreen remote display
M765RDPS Remote display kit, includes M765RD, 24 VDC power supply, 4
metre Ethernet cable
P32UEP813-1000A 1000 A / 1 VAC Universal Technic Clamp On Current Probe
P32UEP815-3000A 3000 A / 1 VAC Universal Technic Clamp On Current Probe
SCT0750-005-5A 5 A / 0.333 VAC Magnelabs Split Core Current Probe
SCT1250-300-300A 300 A / 0.333 VAC Magnelabs Split Core Current Probe
(1) Firmware version 350 or higher required.
P
C 1
Advanced metering
113
PLSED309005EN
ION7550 / ION7650 0
Dimensions and connection
ION7550/ION7650 dimensions
PE86022
PE86023
ION7550 / ION7650 TRAN dimensions
PE86024
PE86025
PE86026
Front-panel mounting
ION7550 and ION7650 meter can have integrated or remote
display. The meter with integrated display is designed to t
DIN standard 192 cutout (186 mm by 186 mm) . The remote
display is intalled through a circular cutout (22.5 mm diameter)
at the panel door. It has a front and a back module, and
communicates with the meter via serial (RS485) or Ethernet.
PE86027
Advanced metering
114 PLSED309005EN
Advanced metering
The PowerLogic Circuit Monitor Series 4000 offers high-performance digital
instrumentation, data acquisition and control capabilities. The products can integrate
easily in power monitoring and control systems due to their optional Ethernet
connections and embedded web server. They are Transparent Ready.
These devices are designed for applications where power quality and availability are
critical factors. They are generally used at service entrances and interconnection
points or on circuits feeding sensitive equipment. Due to their very wide range of
features, including transient detection (CM4000T only), it is possible to rapidly solve
problems related to poor power quality. EN 50160 compliance checking capability
makes these products ideal to meet new needs related to market deregulation.
The Circuit Monitor Series 4000 is available in two versions:
b CM4250, with detection of voltage sags, swells and other power quality indices
b CM4000T, with detection of voltage sags and swells together with transient
detection and icker measurements.
Applications
Panel instrumentation.
Sub-billing / cost allocation.
Remote monitoring of an electrical installation.
Extensive power-quality monitoring.
Contract and load curve optimisation.
EN 50160 electrical supply compliance checking.
Metering of other utilities.
Main characteristics
Disturbance direction detection
Indication of whether the source of a specic power quality event is upstream or
downstream from the meter.
Power quality summary
Consolidation of all the power quality characteristics into a single trendable index.
Adaptive waveform capture
Capture of long-duration events.
Shift energy summary
Indication of energy usage per shift up to three shifts a day.
Detection and capture of voltage sags and swells
Fast identication of problems causing production shutdown.
Detection and capture of short transients less than 1 µs
(optional, CM4000T only)
Identication of problems due to short disturbances, e.g. switching of capacitors, etc.
Flicker evaluation based on IEC 61000-4-15 and IEEE 1453 (CM4000T only)
Measurement of rapid voltage variations.
Electrical quality checking in compliance with EN 50160
Fast standardised check on the quality of the electricity supplied.
Detection of major waveform changes
Detection of phase switching phenomena (for example during the transfer of a high-
speed static switch) not detected by classical threshold-based alarms.
Ultra-fast recording of electrical parameters every 100 ms or every cycle
Preventive maintenance: acquisition of a motor startup curve, etc.
Trend curves and short-term forecasting
Rapid trending and forecasting of upcoming values for better decision making.
Automatic alarm setting
Alarm setpoint learning feature for optimum threshold settings.
Up to 32 Mbytes of memory (16 Mbytes standard)
For archiving of data and waveforms.
Ethernet 10/100 Mbits/s card and server for HTML pages
(with optional Ethernet card)
Rapid data transfers over an intranet or the internet, simply using a web browser.
Alarm notication via email
High-priority alarms sent directly to the user’s PC.
Instant notication of power quality events by email.
Up to 25 inputs/outputs to monitor the electrical installation
(with optional I/O cards)
Status of circuit breakers, as well as metering of other commodities, e.g. gas, water, etc.
IEC 62053-22 and ANSI C12.20 Class 0.2S for energy
Verication of consumption and load curves.
PE86140
CM4000 + vacuum uorescent display (VFD).
Circuit Monitor Series 4000
Functions and characteristics
115
PLSED309005EN
Advanced metering
Part numbers
Circuit Monitor Series 4000
Circuit Monitor CM4250 CM4250
Circuit Monitor CM4000T CM4000T
DB108168
CM4000 series.
1 Current/voltage module.
2 Control power-supply connector.
3 Maintenance LED indicator.
4 Power LED indicator.
5 RS 485 port with transmit and receive LED indicators.
6 Display communication port.
7 Slots for optional cards.
8 RS 232 port with transmit and receive LED indicators.
9 KYZ pulse output.
10 Sealable access door.
Selection guide CM4250
General
Use on LV and HV systems b b
Current and voltage accuracy 0.07 % 0.07 %
Energy and power accuracy 0.2 % 0.2 %
Nbr of samples/cycle or sample frequency 512 5 MHz
Instantaneous rms values
Current, voltage, frequency b b
Active, reactive, apparent power Total and per phase b b
Power factor Total and per phase b b
Energy values
Active, reactive, apparent energy b b
Settable accumulation modes b b
Demand values
Current Present and max. values b b
Active, reactive, apparent power Present and max. values b b
Predicted active, reactive, apparent power b b
Synchronisation of the measurement window b b
Setting of calculation mode Block, sliding b b
Power quality measurements
Interharmonics b-
Harmonic distortion Current and voltage b b
Individual harmonics Via monitor 63 63
Via SMS 255 255
Waveform capture b b
Detection of voltage swells and sags b b
Adaptive waveform capture (up to 64 s) b b
Detection and capture of transients (< 1 µs) -b
Flicker - b
Fast acquisition of 100 ms or cycle by cycle data b b
EN 50160 compliance checking (1) b b
Programmable (logic and math functions) b b
Data recording
E87306
Min/max of instantaneous values b b
Data logs b b
Event logs b b
Trending/forecasting b b
Alarms (optional automatic alarm setting) b b
Alarm notication via email ECC21 option
SER (Sequence of Event Recording) b b
Time stamping b b
GPS synchronisation (1 ms) IOC44 option
Memory expandable up to 32 Mbytes 32 Mbytes
Display and I/O
Display CMDLC or CMDVF option
Multilingual: English, French, Spanish, German, Italian, Polish b b
Wiring self-test b b
Pulse output b b
Disturbance waveform capture: detection of a voltage sag. Maximum number of I/Os 25 25
Input metering capability (number of channels) 10 10
Direct voltage connection 690 V 600 V
Communication
RS 485 port 2/4 wires 2/4 wires
RS 232 port b b
Modbus protocol b b
Ethernet card (Modbus/TCP/IP protocol) ECC21 option
HTML-page web server ECC21 option
Ethernet gateway for third-party products ECC21 option
(1) Except for interharmonics, signalling voltages, icker and transients.
Circuit Monitor Series 40000
Functions and characteristics (cont.)
116 PLSED309005EN
Advanced metering
The Circuit Monitor has two optional display units, an LCD display and a vacuum
uorescent display (VFD). They may be used for local circuit-monitor setup and
operation.
PE86143
CMDLC display
Back-lit LCD display with four lines and 20 characters per line. The display unit has
four navigation buttons, a contrast button and a red alarm LED.
It connects to the Circuit Monitor via a CAB12 cable, 4.2 metres long, supplied with
the display.
Part numbers
LCD display supplied with the CAB12 cable CMDLC
Connection cables:
Circuit Monitor <-> display
1.25 m (4 ft) CAB4
3.65 m (12 ft) CAB12
9.14 m (30 ft) CAB30
PE86142
CMDVF display
Vacuum uorescent display (VFD) with four lines and 20 characters per line.
The display unit has four navigation buttons, a contrast button, a red alarm LED.
The display comes with a cable for connection to the Circuit Monitor (CAB12 cable,
4.2 m long).
Part numbers
VFD supplied with the CAB12 cable CMDVF
Connection cables:
Circuit Monitor <-> display
1.25 m (4 ft) CAB4
3.65 m (12 ft) CAB12
9.14 m (30 ft) CAB30
E87288
1 Display screen.
2 Alarm LED.
3 Arrow buttons.
4 Menu button.
5 Proximity sensor (VFD display only).
6 Enter button.
7 Contrast button.
Display.
Circuit Monitor Series 4000 0
Functions and characteristics (cont.)
117
PLSED309005EN
Advanced metering
PE86141
CM4000 + options: ECC21, IOC44 and IOX2411.
Electrical characteristics
Type of measurement True rms up to the 255th harmonic
On three-phase AC system (3P, 3P + N)
Up to 512 samples per cycle
Up to 5 MHz for transient events (CM4000T
only)
Measurement
accuracy
Current and voltage ±0.04 % of reading + ±0.025 % of full scale
Power ±0.075 % of reading + ±0.025 % of full scale
Frequency ±0.01 Hz from 45 to 67 Hz
±0.1 Hz from 350 to 450 Hz
Power factor ±0.002 from 0.5 leading to 0.5 lagging
Energy:
CM4250/CM4000T
IEC 62053-22 and ANSI C12.20 Class 0.2S
Data update rate 1 s in normal mode
Input-voltage
characteristics
Measured voltage 0 to 600 V AC on CM4000T (direct)
0 to 690 V AC on CM4250 (direct)
0 to 1200 kV AC (with external VT)
Measurement range 0 to 1.5 Un
Impedance > 2 MW
Frequency measurement
range
45 to 67 Hz and 350 to 450 Hz
Input-current
characteristics
CT ratings Adjustable from 5 A to 30 000 A
Measurement range
CM4250/CM4000T
5 mA to 10 A
Permissible overload 15 A continuous
50 A for 10 seconds per hour
500 A for 1 second per hour
Impedance < 0.1 W
Load < 0.15 VA
Power supply AC 100 to 275 V AC (±10 %), 50 VA
DC 125 to 250 V DC (±20 %), 30 W
Ride-through time 100 ms at 120 V DC
Input/outputs Pulse output Static output (240 V AC max, 96 mA max)
IOC44 card (optional) 4 digital inputs (20-138 V AC/DC),
3 relay outputs (5 A to 240 V AC)
1 static output (96 mA max to 240 V AC)
IOX extender (optional) Slots for 8 I/Os
IOX08 (optional) 8 digital inputs 120 V AC
IOX0404 (optional) (1) 4 dig. inputs 120 V AC, 4 analogue outputs
4-20 mA
IOX2411 (optional) (1) 2 dig. outputs 120 V AC, 4 dig. inputs 32 V DC,
1 analogue input 0-5 V, 1 analogue output 4-20
mA
Mechanical characteristics
Weight 1.9 kg
IP degree of protection (IEC 60529) IP52
Dimensions
CM4250/
CM4000T
Without IOX accessory 235.5 x 165.6 x 133.1 mm
With IOX accessory 235.5 x 216.3 x 133.1 mm
Environmental conditions
Operating
temperature
Circuit Monitor -25 °C to +70 °C
CMDLC display -20 °C to +60 °C
CMDVF display -20 °C to +70 °C
Storage
temperature
CM + displays -40 °C to +85 °C
Humidity rating 5 to 95 % RH at 40 °C
Pollution degree 2
Installation
category
CVM42 IV
CVMT II
Dielectric withstand As per EN 61010, UL508, CSA C22.2-2-
4-M1987
Electromagnetic compatibility
Electrostatic discharge Level 3 (IEC 61000-4-2)
Immunity to radiated elds Level 3 (IEC 61000-4-3)
Immunity to fast transients Level 3 (IEC 61000-4-4)
Immunity to impulse waves Level 4 (IEC 61000-4-5)
Conducted and radiated emissions e industrial envir./FCC part 15 class A
Safety
Europe e, as per CEI 61010
USA and Canada UL508 and CSA C22.2-2-4-M1987
(1) Operating limits: 0° C to +60 °C. Storage limits: -25 °C to +85 °C.
Circuit Monitor Series 4000 0
Functions and characteristics (cont.)
118 PLSED309005EN
Advanced metering
E87307
Communication
RS 485 port (1) 2/4 wires, up to 38400 bauds, Modbus
RS 232 port (1) Up to 38400 bauds, Modbus, direct connection to a PC
or modem
Ethernet ECC21 card with HTML server (optional) (1)
Copper Ethernet link 10/100 BaseTX, RJ45 connector, 100 m link
Fiber-optic Ethernet link 100 Base FX, LC duplex connector, 1300 nm, FO
multimode with gradient index 62.5/125 µm or 50/125
µm, 2000 m link
Protocol Modbus/TCP/IP
Gateway function for products
connected to the ECC21
Master Modbus port, 31 daisy-chained slaves,
63 with repeater, 2/4 wires, 1200 to 38400 bauds,
also compatible with the PowerLogic protocol
HTML server 1 standard page, 5 customisable pages
Firmware characteristics
Adaptive waveform capture: transformer inrush current. 14 data logs Up to 96 different parameters, factory-set logs ready
to use
One 100 ms data log Parameters recorded every 100 ms for events
One 20 ms (50 Hz) or 16 ms (60 Hz)
data log
Parameters recorded every 20 ms or 16 ms for events
E87308
One min/max log -
One min/max/avg. log Min/max/avg. values recorded for 23 parameters at
regular intervals from 1 to 1440 minutes
One event log Time stamping to 1 ms, synchro. 1 ms by GPS
Trend curves Four trend curves: 1 minute, 1 hour, 1 day and 1 month.
Min./max./avg. values recorded for eight parameters:
- every second for one minute for the 1-minute curve
- every minute for one hour for the 1-hour curve
- every hour for one day for the 1-day curve
- every day for one month for the 1-month curve
Forecasting Forecasting of the values for the eight parameters
for the next four hours and next four days
Waveform captures Standard: manual launch, 1 cycle, 512 samples, 255th
harmonic
Disturbance: manual launch or by alarm, adjustable
from 512 samples/cycle over 28 cycles to 16 samples/
cycle over 915 cycles, response time less than 0.5 cycle,
number of cycles before alarm settable from 2 to 10
Adaptive: manual launch or by alarm, adjustable from
512 samples/cycle over 8 seconds to 16 samples/
cycle over 264 seconds, capture takes place during a
set duration or as long as an alarm is active (to save
memory), number of cycles before alarm settable from
2 to 10
Transient: voltage sampling at 5 MHz (83 333 samples/
cycle) over 2 ms to capture transient peaks < 1 µs
Adaptive waveform capture: motor start, rms value.
E87309
Alarms Threshold alarms:
- adjustable pickup and dropout setpoints and time
delays, numerous activation levels possible for a given
type of alarm
- 4 priority levels
- 4 response times: standard 1 s, fast 100 ms,
disturbance < 1/2 cycle, transient < 1µs
- boolean combination of four alarms is possible using
the operators NAND, OR, NOR and XOR
Automatic alarm setting: after a learning phase, the
alarm thresholds are set automatically. The alarms will
trip in the event of drift with respect to reference values
determined during the learning period.
Digital alarms: logic input transitions
Waveform alarms: alarm tripping by a special algorithm
when the current or voltage waveform is distorted
beyond an adjustable level. Makes it possible to detect
disturbances that cannot be detected by classical
threshold alarms (e.g. phase switching).
Example CM4250 HTML page showing instantaneous values.
Memory 8 Mbytes standard, expandable up to 32 Mbytes
Firmware update Update via the communication ports
Display characteristics
CMDLC (optional) Back lit LCD
CMDVF (optional) Vacuum uorescent display (VFD) with IR port
Languages English, French, Spanish, German, Italian, Polish
(1) All the communication ports may be used simultaneously.
Circuit Monitor Series 4000 0
Functions and characteristics (cont.)
119
PLSED309005EN
CM4250 / CM4000T dimensions
E94393
E94394
E94392
Mounting on a backplate
DB108169
Advanced metering Circuit Monitor Series 4000
Dimensions and connection
120 PLSED309005EN
Advanced metering Circuit Monitor Series 4000
Dimensions and connection
Mounting possibilities
DB108007
DB108005DB108006
Vertical mounting. Horizontal mounting.
CMDLC/CMDVF dimensions
E87286E87285
Mounting on a backplate
E94377
121
PLSED309005EN
ION8650
Functions and characteristics
Advanced utility metering
PB107500
PowerLogic ION8650 socket meter
Used to monitor electric energy provider networks, service entrances and
substations, PowerLogic ION8650 meters are ideal for independent power
producers and cogeneration applications that need to accurately measure energy
bi-directionally in both generation and stand-by modes. These meters give utilities
the tools to manage complex energy supply contracts that include commitments to
power quality. Integrate them with our StruxureWare Power Monitoring (ION
Enterprise™) operations software or other energy management and SCADA
systems through multiple communication channels and protocols, including Itron
MV-90, Modbus, DNP, DLMS, IEC 61850 Ed. 2.
Applications
Revenue metering.
Co-generation and IPP monitoring.
Compliance monitoring.
Power quality analysis.
Demand and power factor control.
Load curtailment.
Equipment monitoring and control.
Energy pulsing and totalisation.
Instrument transformer correction.
Main characteristics
ANSI Class 0.2 and IEC 62053-22/23 Class 0,2S metering
For interconnection points on medium, high, and ultra-high voltage networks; twice
as accurate as current IEC and ANSI Class 0.2 standards over all conditions and
including single wide range current measurement.
Power quality compliance monitoring
Monitor compliance with international quality-of-supply standards (IEC 61000-4-30
Class A/S, EN 50160 Ed. 4, IEC 61000-4-7, IEC 61000-4-15, IEEE 1159, IEEE 519).
Also detects disturbance direction.
Digital fault recording
Simultaneous capture of voltage and current channels for sub-cycle disturbance.
Complete communications
Multi-port, multi-protocol ports including serial, infrared, modem and ethernet.
Simultaneously supports multiple industry standard protocols including: Itron MV-90,
Modbus, Modbus Master, DLMS, DNP 3.0 and IEC 61850 Ed. 2.
Multiple tariffs and time-of-use
Apply tariffs, seasonal rate schedules to measure energy and demand values for
time periods with specic billing requirements.
Multiple setpoints for alarm and functions
Use up to 65 setpoints for single/multi-condition alarms and I/O functions with
response times down to 1/2 cycle.
Multiple setpoints for alarm and functions
Use up to 65 setpoints.
Instrument transformer correction
Save money and improve accuracy by correcting for less accurate transformers.
Alarm notication via email
High-priority alarms, data logs sent directly to the user’s PC. Instant notication of
power quality events by email.
Cyber security enhancements
Assign communication admin rights to selected user; prevention measures ensure
no loss of security logs; support syslog for external security.
Part numbers
ION8650 meters
ION8650A M8650A
ION8650B M8650B
ION8650C M8650C
122 PLSED309005EN
ION8650
Functions and characteristics (cont.)
Advanced utility metering
PE86302-95
PowerLogic ION8650 socket meter.
1 Terminals
2 Optical port
3 Main display status bar
4 Watt LED
5 Navigation, ALT/Enter buttons
6 VAR LED
7 Nameplate label
8 Demand reset switch
Selection guide ION8650
A
ION8650
B
ION8650
C
General
Use on LV, MV and HV systems bbb
Current accuracy 0.1 % 0.1 % 0.1 %
Voltage accuracy 0.1 % 0.1 % 0.1 %
Power accuracy 0.1 % 0.1 % 0.1 %
Samples/cycle 1024 1024 1024
Instantaneous values
Current, voltage, frequency bbb
Active, reactive, apparent power Total & per phase bbb
Power factor Total & per phase bbb
Current measurement range 0 - 20A 0 - 20A 0 - 20A
Energy values
Active, reactive, apparent energy bbb
Settable accumulation modes bbb
Demand values
Current Present & max. values bbb
Active, reactive, apparent power Present & max. values bbb
Predicted active, reactive, apparent power bbb
Synchronisation of the measurement window bbb
Demand modes: Block (sliding), thermal (exponential) bbb
Power quality measurements
Harmonic distortion Current & voltage bbb
Individual harmonics Via front panel 63 63 31
Waveform / transient capture b / b- / b- / -
Harmonics: magnitude, phase, and interharmonics 50 40 -
Detection of voltage sags and swells bbb
IEC 61000-4-30 class A /S AS-
IEC 61000-4-15 (Flicker) bb-
High speed data recording (down to 10 ms) bb-
EN50160 compliance reporting bb-
Programmable (logic and math functions) bbb
Data recording
PE86002
Disturbance waveform capture and power quality report
Onboard Memory (in Mbytes) 128 64 32
Revenue logs bbb
Event logs bbb
Historical logs bbb
Harmonics logs bbb
Sag/swell logs bbb
Transient logs b- -
Time stamping to 1 ms bbb
GPS synchronisation (IRIG-B standard) bbb
Display and I/O
Front panel display bbb
Wiring self-test (requires PowerLogic ION Setup) bbb
Pulse output (front panel LED) 222
Digital or analogue inputs(1) (max) 11 11 11
Digital or analogue outputs(1) (max, including pulse output) 16 16 16
Communication
Infrared port 111
RS 485 / RS 232 port 111(3)
RS 485 port 111(3)
Ethernet port (Modbus/TCP/IP protocol) with gateway 111(3)
Internal modem with gateway (ModemGate) 111(3)
HTML web page server bbb
IRIG-B port (unmodulated IRIG B00x time format) 111
Modbus TCP Master / Slave (Ethernet port) b / b b / b- / b
Modbus RTU Master / Slave (Serial ports) b / b b / b- / b
DNP 3.0 through serial, modem, and I/R ports bbb
(1) With optional I/O Expander.
(2) For 9S, and 36S only. For 35S system up to 480V line-to-line.
(3) C model limited to IR + 2 other ports at one time. Ports can be enabled/disabled by user.
123
PLSED309005EN
ION8650
Functions and characteristics (cont.)
Advanced utility metering
PE86041
PowerLogic ION8650 front panel harmonic display.
Electrical characteristics
Type of measurement True rms 1024 samples per cycle
Measurement
accuracy
Current and voltage 0.1 % Reading
Power 0.1%
Frequency ±0.001 Hz
Power factor 0.1%
Energy 0.1%, twice as accurate as ANSI Class 0.2 and
IEC 62053-22/23 (0,2S)
Data update rate 0.5 cycle or 1 second (depending on value)
Input-voltage
characteristics (1)
Nominal voltage 57V to 277VLN rms
100V to 480VLL rms (35S)
Maximum voltage 347 VLN rms, 600 VLL rms (9S)
Impedance 5 MW /phase (phase-Vref/Ground)
Inputs V1, V2, V3, VREF
Input-current
characteristics
Rated nominal/current
class
1A, 2 A, 5 A and/or 10 A (Class 1/2/10/20)
Accuracy range 0.01 - 20 A (standard range)
Measurement range 0.001 - 24 A
Permissible overload 500A rms for 1 second, non-recurring
Burden per phase Socket: Typical: 3 W, 8 VA/phase, 3-phase
operation; Maximum: 4 W, 11 VA/phase,
3-phase operation
Switchboard: 0.05VA at 1A (0.05 Ω max)
Power supply Standard power supply,
blade powered
120-277 VLN RMS (-15%/+20%) 47-63 Hz or
120-480 VLL RMS (-15%/+20%) 47-63 Hz (35S)
Auxiliary powered low
voltage
AC: 65-120 (+/- 15%) VLN RMS, 47-63 Hz
DC: 80-160 (+/- 20%) VDC
Auxiliary powered high
voltage
AC: 160-277 (+/- 20%) VLN RMS, 47-63 Hz
DC: 200-300 (+/- 20%) VDC
Ride-through time,
(Standard power supply)
Socket: min guaranteed: 6 cycles at nominal
frequency (minimun 50 Hz), at 120 V L-N rms
(208 V L-L rms) 3-phase operation
Switchboard: min guaranteed: 6 cycles at
nominal frequency (minimun 50 Hz), at 120 V
L-N rms (208 V L-L rms) 3-phase operation
Input/outputs (2) Digital outputs 4 (Form C) Solid state relays (130 V AC/ 200 V
DC) 50 mA AC/DC, 1 (Form A) output
Digital inputs upto 3 Self-excited, dry contact sensing inputs
PE86042
ION8650 front panel phasor display and table.
Mechanical characteristics
Weight 7.0 kg
IP degree of
protection
Socket Front IP65, back IP51
Switchboard Front IP50, back IP30
Dimensions Socket 178 x 237 mm
Switchboard 285 x 228 x 163 mm
Environmental conditions
Operating temperature -40°C to +85°C
Display operating range -40°C to +70°C
Storage temperature -40°C to +85°C
Humidity rating 5 to 95 % RH non-condensing
Pollution degree 2
Installation category Cat III
Dielectric withstand 2.5kV
Electromagnetic compatibility
Electrostatic discharge IEC 61000-4-2
Immunity to radiated elds IEC 61000-4-3
Immunity to fast transients IEC 61000-4-4
Immunity to surge IEC 61000-4-5
Immunity conducted IEC61000-4-6
Damped oscillatory waves immunity IEC61000-4-12
Conducted and radiated emissions CISPR 22 (class B)
Safety
Europe As per IEC62052-11
North America As per ANSI C12.1
(1) Specications are limited by the operating range of the power supply if a non-aux power supply is used.
(2) More input and output selections available via optional I/O expander.
124 PLSED309005EN
ION8650
Functions and characteristics (cont.)
Advanced utility metering
Example embedded webserver page (WebMeter) showing
realtime values.
Communication
RS 232 / RS 485 port (COM1) User-selectable RS 232 or RS 485.
300 - 115,200 bauds (RS485 limited to 57,600 bps);
protocols: ION, Modbus/RTU/Mastering, DLMS, DNP 3.0,
GPSTRUETIME/DATUM.
Internal modem port (COM2) 300-57,600 bps
ANSI 12.18 Type II optical port
(COM3)
Up to 57,600 bps
RS 485 port (COM4) Up to 57,600 bauds, Modbus, direct connection to a PC
or modem
Ethernet port 10/100 BaseT, RJ45 connector, protocols:
DNP, ION, Modbus/TCP/Mastering, IEC 61850 Ed. 2
or 100BASE-FX multimode, male ST connectors
EtherGate Up to 31 slave devices via serial ports
ModemGate Up to 31 slave devices
Firmware characteristics
High-speed data recording Up to 1/2-cycle interval burst recording, stores detailed
characteristics of disturbances or outages. Trigger
recording by a user-dened setpoint, or from external
equipment.
Harmonic distortion Up to 63rd harmonic for all voltage and current inputs
Dip/swell detection Analyse severity/potential impact of sags and swells:
- magnitude and duration data suitable for plotting on
voltage tolerance curves
- per phase triggers for waveform recording or control
operations
Instantaneous High accuracy measurements with 1s or 1/2 cycle update
rate for:
- voltage and current
- active power (kW) and reactive power (kVAR)
- apparent power (kVA)
- power factor and frequency
- voltage and current unbalance
- phase reversal
Load proling Channel assignments are user congurable:
- 800 channels via 50 data recorders (feature set A),
- 720 channels via 45 data recorders (feature set B),
- 80 channels via 5 data recorders (feature set C).
Congure for historical trend recording of energy,
demand, voltage, current, power quality, other measured
parameter. Recorders can trigger on time interval basis,
calendar schedule, alarm/event condition, manually.
Waveform captures Simultaneous capture of all voltage and current channels
- sub-cycle disturbance capture (16 to 1024 samples/
cycle)
PE86005-C
Alarms Threshold alarms:
- adjustable pickup and dropout setpoints and time
delays, numerous activation levels possible for a given
type of alarm
- user-dened priority levels
- boolean combination of alarms
Advanced security Up to 50 users with unique access rights. Perform resets,
time syncs, or meter congurations based on user
priviledges.
Transformer correction Correct for phase / magnitude inaccuracies in current
transformers (CTs), potential transformers (PTs)
Memory 128 Mbytes (A), 64 Mbytes (B), 32 Mbytes (C)
Firmware update Update via the communication ports
Display characteristics
Type FSTN transreective LCD
Backlight LED
Languages English
125
PLSED309005EN
ION8650
Functions and characteristics (cont.)
Advanced utility metering
Part Numbers
Item Code Description
PE86043-C
Example product part number.
1 Model M8650 Schneider Electric energy and power quality meter.
2Feature Set A128MB Memory Class A power quality analysis, waveforms and
transient capture with 1024 samples/cycle.
B64MB memory, energy meter Class S EN 50160 Ed. 4 power
quality monitoring.
1 Model.
2 Feature set.
3 Form factor.
4 Current Inputs.
5 Voltage inputs.
6 Power supply.
7 System frequency.
8 Communications.
9 Input/output options.
10 Security.
11 Special order options.
C32MB memory, basic tariff/energy metering (5 data recorders,
80 channels).
3Form Factor (1) 0Form 9S/29S/36S Base, 57-277 VLN (autoranging)
3-Element, 4-Wire / 2 1/2-Element, 4-Wire
1Form 35S Base - 120-480 VLL (autoranging) 2-Element,
3-Wire
4Form 9/29/35/36S FT21 Switchboard (meter + case) with break
out panel
7Form 9/29/35/36S FT21 Switchboard (meter + case) with break
out cable
4Current Inputs C1, 2 or 5 Amp nominal, 20 Amp full scale (24 Amp fault
capture, start at 0.001 A)
5Voltage Inputs 0Standard (see Form Factor above)
PB107507
6Power Supply EForm 9/29/35/36S, (socket) and Form 9, 36 (FT21
switchboard): 120-277 VAC. Form 35S (socket) and Form 35
(FT21 switchboard): 120-480 VAC. Powered from the meter’s
voltage connections.
HAuxiliary Power Pigtail: 65-120 VAC or 80-160 VDC
(power from external source)
JAuxiliary Power Pigtail: 160-277 VAC or 200-300 VDC
(power from external source)
7System Frequency 5Calibrated for 50 Hz systems.
6Calibrated for 60 Hz systems.
8 Communications A 0 Infrared optical port, RS 232/RS 485 port, RS 485 port
PowerLogic ION8650 meter with switchboard case
C 7 Infrared optical port, Ethernet (10/100Base-T), RS 232/485
port, RS 485 port (note: in addition to infrared optical port,
Feature Set C can use any two ports (congurable)), 56k
universal internal modem (RJ11)
E 1 Infrared optical port, Ethernet (10/100Base-T), RS 232/485
port, RS 485 port (note: in addition to infrared optical port,
Feature Set C can use any two ports (congurable))
F 1 Infrared Optical port, Ethernet (100BASE-FX multi-mode)
with male ST connectors (available on socket meters only,
Forms 0 & 1 above. I/O card not available if this option is
ordered.) RS-232/485 port, RS-485 port (Note: in addition to
Infrared Optical port Feature Set C can use any two ports
(congurable))
M 1 Infrared optical port, RS 232/485 port, RS 485 port (note: in
addition to infrared optical port, Feature Set C can use any
two ports (congurable)), 56k universal internal modem
(RJ11).
S 0 Infrared optical port, Ethernet (10 BaseT), RS 232/485 port,
RS 485 port (note: in addition to infrared optical port, Feature
Set C can use any two ports (congurable)), Verizon cell
modem.
9Onboard I/O A None.
B4 Form C digital outputs, 3 Form A digital inputs.
C4 Form C digital outputs, 1 Form A digital output, 1 digital
input.
10 Security 0 Password protected, no security lock
1Password protected with security lock enabled (requires
removal of outer cover to congure billing parameters)
3RMICAN (Measurement Canada approved)
4RMICAN-SEAL (Measurement Canada approved, and factory
sealed)**
11 Special Order A None
(1)Specications are limited by the operating range of the power supply if a non-aux power supply is used.
126 PLSED309005EN
ION8650
Functions and characteristics (cont.)
Advanced utility metering
Part numbers (cont.)
PE86044
I/O Expander
Digital/Analogue I/O P850E Schneider Electric I/O Expander for ION8600 meters: Inputs and
Outputs for energy pulsing, control, energy counting, status
monitoring, and analogue interface to SCADA.
Example order code. Use this group of codes when ordering
the I/O Expander.
I/O option AExternal I/O box with 8 digital inputs and 8 digital outputs
(4 Form A, 4 Form C)
1 Digital / Analogue I/O.
2 I/O option.
3 Cable option.
BExternal I/O box with 8 digital inputs and 4 digital outputs
(4 Form C) and 4 analogue outputs (0 to 20mA)
CExternal I/O box with 8 digital inputs and 4 digital outputs
(4 Form C) and 4 analogue outputs (-1mA to 1mA)
PE86131
DExternal I/O box with 8 digital inputs and 4 digital outputs
(4 Form C) and 4 analogue outputs (two -1 to 1 mA, and two 0 to
20 mA outputs)
Cable option 0No cable - cables for the I/O box are no ordered as a separate
part number. Refer to part numbers: CBL-8X00IOE5FT,
CBL-8X00IOE15FT and CBL-8XX0-BOP-IOBOX under
Connector cables, below.
A-base adapters
A-BASE-ADAPTER-9 Form 9S to Form 9A adapter
A-BASE-ADAPTER-35 Form 35S to Form 35A adapter
Optical communication interface
OPTICAL-PROBE Optical communication interface
Connector cables
CBL-8X00BRKOUT 5’ extension cable, mates with 24-pin male Molex connector from
the meter to the 24-pin Molex connector on the I/O expander box
(not for use with breakout panel E8, F8 & G8 form factors)
CBL-8X00IOE5FT 15’ extension cable, mates with 24-pin male Molex connector
from the meter to the 24-pin Molex connector on the I/O
expander box (not for use with breakout panel E8, F8 & G8 form
factors)
CBL-8X00IOE15FT 15’ extension cable, mates with 24-pin male Molex connector
from the meter to the 24-pin female Molex connector on the I/O
Expander box (not for use with breakout panel E8, F8 & G8 form
factors)
CBL-8XX0-BOP-IOBOX 6’ connector cable, 24-pin male to 14-pin male Molex connector
for connecting an ION8000Series meter with breakout panel to
an I/O Expander Box
A2
P 8 5 0 E
127
PLSED309005EN
ION8650
Dimensions and connections
Advanced utility metering
ION8650 socket dimensions
PE86303
PE86304
ION8650 switchboard dimensions
PE86305
PE86306
I/O Expander dimensions
PE86307
PE86308
128 PLSED309005EN
Advanced utility metering ION8650
Dimensions and connections (cont.)
ION8650 suggested switchboard mounting dimensions
PE86052
ION8650 switchboard mounting
PE86309
129
PLSED309005EN
ION8800
Functions and characteristics
Advanced utility metering
PE86176
Providing high accuracy and a wide range of features for transmission and
distribution metering, the PowerLogic ION8800 advanced revenue and power quality
meter has the exibility to change along with your needs. The meter provides the
tools necessary to:
b manage energy procurement and supply contracts
b perform network capacity planning and stability analysis’
b monitor power quality compliance, supply agreements, and regulatory
requirements.
Integrate the PowerLogic ION8800 meter with your existing wholesale settlement
system, use StruxureWare Power Monitoring (PowerLogic ION Enterprise™)
software, or share operations data with SCADA systems through multiple
communication channels and protocols.
Applications
Transmission and distribution metering.
Settlements, customer billing, cost allocation.
Extensive power quality monitoring and analysis.
Contract optimisation and compliance verication.
Main characteristics
IEC 19-inch rack mount design to DIN 43862 standard
Use Essailec connectors with common measurement and energy pulsing pin-out to
easily retrot into existing systems.
Accurate metering
Interconnection points on medium, high, and ultra-high voltage networks are in
compliance with IEC 62053-22/23 Class 0,2S.
Power quality compliance monitoring
Monitor compliance with international quality-of-supply standards (IEC 61000-4-30
Class A/S, EN50160, IEC 61000-4-7, IEC 61000-4-15, IEEE 1159, IEEE 519, IEC
61000-4-30 (edition 2) Class A/S).
Power quality summary
Consolidate power quality characteristics into easily viewable reports indices.
Digital fault recording
Capture voltage and current channels simultaneously for sub-cycle disturbances.
Complete communications
Use the IEC1107 optical port or the optional communications module that supports
concurrent Ethernet, serial, and modem communications.
Multiple tariffs and time-of-use
Apply tariffs and seasonal rate schedules to measure energy and demand values for
time periods with specic billing requirements.
Alarms and I/O functions
Use up to 65 setpoints for single/multi-condition alarms and I/O functions with
response times down to 1/2 cycle.
Alarm notication via email
High-priority alarms, data logs sent directly to the user’s PC. Instant notication of
power quality events by email.
Software integration
Easily integrate the meter with StruxureWare Power Monitoring (ION Enterprise) or
other utility software; MV-90, Pacis and third-party SCADA packages.
Transformer/line loss compensation
Compensate for system losses in real time directly in the meter.
Instrument transformer correction
Save money and improve accuracy by correcting for less accurate transformers.
PowerLogic™ ION8800 meter
Part numbers(1)
PowerLogic ION8800 meters
PowerLogic ION8800A M8800A
PowerLogic ION8800B M8800B
PowerLogic ION8800C M8800C
(1)Representative part numbers only. See page 9 for complete part number descriptions.
130 PLSED309005EN
ION8800
Functions and characteristics (cont.)
Advanced utility metering
PE86001
PowerLogic ION8800 meter
1 Optional communications module.
2 Essailec connectors.
3 Internal modem.
4 Optional Ethernet communications.
5 Selectable RS 485 serial port.
6 Selectable RS 232 or RS 485 serial port.
7 Ground terminal.
Selection guide ION8800A
ION8800B
ION8800C
General
Use on LV, MV and HV systems b b
Current accuracy 0.1 % 0.1 %
Voltage accuracy 0.1 % 0.1 %
Power accuracy 0.2 % 0.2 %
Samples/cycle 1024 1024
Instantaneous rms values
Current, voltage, frequency (Class 0,2S) b b
Active, reactive, apparent power Total and per phase b b
Power factor Total and per phase b b
Current measurement range 0.001 - 10A 0.001 - 10A
Current measurement range 0.001 - 10A 0.001 - 10A
Energy values
Active, reactive, apparent energy b b
Settable accumulation modes b b
Demand values
Current b b
Active, reactive, apparent b b
Predicted active, reactive, apparent b b
Demand modes (block, sliding, thermal, predicted) b b
Power quality measurements
Detection of voltage dips (sags) and swells 10 ms 10 ms
Symmetrical components: zero, positive, negative b-
Transient detection, microseconds (50 Hz) 20 (1) 20 (1)
Harmonics: individual, even, odd, total up to 63rd 63rd
Harmonics: magnitude, phase and inter-harmonics 50th 40th
EN 50160 compliance b
IEC 61000-4-30 class A b
IEC 61000-4-30 class S b (2)
IEC 61000-4-15 (Flicker) b-
PE86235
Congurable for IEEE 519 - 1992, IEEE1159-1995 b(1) -
Programmable (logic and math functions) b b
Data recording
Min/max logging for any parameter b b
Historical logs Maximum # of records 800(1) 640(2) 32
Waveform logs Maximum # of records 96 (1) -
Timestamp resolution in seconds 0.001 0.001
Setpoints, minimum response time ½ cycle ½ cycle
Number of setpoints 65 65
GPS time synchronisation (IRIG-B) b b
Could add transient logs. COMTRADE fault records. b b
User congurable log memory 10 Mbytes 10 Mbytes
Display and I/O
Front panel display b b
Active/reactive energy pulser, LED and IEC 1107 style port b b
Digital pulse outputs, optional Solid state Form A 8 8
Digital pulse outputs Solid state Form C 4 4
Alarm relay output Form C 1 1
Digital inputs (optional) 3 3
Display screen examples: KWh disk simulator, voltage
harmonics histogram, phasor diagram, and name plate1.
Communications
RS 232/485 port 1 1
RS 485 port 1 1
Ethernet port 1 1
IEC 1107 optical port 1 1
Internal modem 1 1
3-port DNP 3.0 through serial, modem, Ethernet and I/R ports b b
Modbus RTU master / slave (serial, modem and I/R ports) b / b- / b
Modbus TCP master / slave (via Ethernet port) b / b- / b
Data transfer between Ethernet and RS 485 (EtherGate) b b
Data transfer between internal modem, RS 485 (ModemGate) b b
Alarms, single or multi-condition b b
Alarm notication & logged data via email b b
Embedded web server (WebMeter) b b
(1) ION8800A only.
(2) ION8800B only.
131
PLSED309005EN
ION8800
Functions and characteristics (cont.)
Advanced utility metering
PE86003
PowerLogic ION8800 with optional communications module.
Electrical characteristics
Type of measurement True rms
1024 samples per cycle
Measurement
accuracy
Current and voltage 0.1 %
Power 0.2 %
Frequency ±0.005 Hz
Power factor 0.1%
Energy IEC 62053-22/23 Class 0.2 S
Data update rate ½ cycle or 1 second
Input-voltage
characteristics
Inputs U1, U2, U3, Uref
Measurement range 57-288 LN VAC rms (99-500 LL VAC rms)
Dielectic withstand 3320 VAC rms
Impedance 5 MW /phase (phase-Uref/Ground)
Input-current
characteristics
Rated nominals 5 A, 1 A, 2 A
Permissible overload 200A rms for 0.5s, non-recurring (IEC 62053-22)
Impedance 10 mW /phase
Burden 0.01 VA per phase (1A), 0.25 VA per phase (5 A)
Power supply AC 85 - 240 VAC (+/- 10%), 47-63 Hz
DC 110 - 270 VDC (+/- 10%)
Burden Typical (without comm module): 13 VA, 8 W
Typical (with comm module): 19 VA, 12 W
Max (without comm module): 24 VA, 10 W
Max (with comm module): 32 VA, 14 W
Ride-through time Typical: 0.5 s to 5 s depending on conguration
Min: 120 ms (6 cycles @ 50 Hz)
Dielectric withstand 2000 VAC
Input/outputs Mechanical alarm relay 1 Form C digital output (250 V AC / 125 V DC,
1 A AC / 0.1 A DC max)
Digital outputs (Form C) 4 Solid state relay outputs (210 V AC / 250 V DC)
100 mA AC/DC
Digital outputs (Form A) 8 Solid state relay outputs (210 V AC / 250 V DC)
100 mA AC/DC
Digital inputs 3 Solid state digital inputs (low-voltage inputs 15
to 75 V AC/DC; high-voltage inputs 75 to 280 V
AC/DC; 3 mA max.)
Pulse rate 20 Hz maximum
Mechanical characteristics
Weight 6.0 kg
(6.5 kg with optional communications module)
IP degree of protection (IEC 60529) IP51
Dimensions 202.1 x 261.51 x 132.2 mm
Environmental conditions
Mounting location Indoor
Maximum altitude 2000 m above sea level
Limit range of operation -25°C to +70°C
Specied operating temperature -10°C to +45°C (as per 62052-11)
Display operating range -10°C to +60°C
Storage temperature -25°C to +70°C
Humidity rating 5 to 95 % RH non-condensing
Pollution degree 2
Installation category Power supply (II) Metering inputs (III)
Electromagnetic compatibility
Electrostatic discharge IEC 61000-4-2
Immunity to radiated elds IEC 61000-4-3
Immunity to fast transients IEC 61000-4-4
Immunity to surge waves IEC 61000-4-5
Conducted immunity IEC 61000-4-6
Damped oscillatory waves immunity IEC 61000-4-12
Conducted and radiated emissions CISPR 22 (class B)
Safety
Europe As per IEC 62052-11
International As per IEC 60950
Utility approval
EGR, GOST, ESKOM, NMI
132 PLSED309005EN
ION8800
Functions and characteristics (cont.)
Advanced utility metering
PE86234
Communication
IEC 1107 optical port 2/4 wires, up to 19200 bauds
RS 485 port Up to 57600 bauds, direct connection to a PC or modem,
protocols: ION, Modbus RTU, Modbus Master, DNP 3.0,
GPSTRUETIME/DATUM, DLMS
Communications module (optional)
RS 232/485 port 300 - 115,200 bauds (RS 485 limited to 57,600 bauds);
protocols: same as RS 485 port
Internal modem port 300 bauds - 56000 bauds, RJ11 connector
Ports on the optional communications module. Ethernet port (supports up to 4
simultaneous connections)
10 BaseT, RJ45 connector, 100 m link; protocols: DNP
TCP, ION, Modbus TCP, Modbus Master, IEC 61850 (in
5MB meters only) supports FTP + COMTRDE.
Fiber-optic Ethernet link 10 Base FL, ST connector, 1300 nm, FO multimode with
gradient index 62.5/125 µm or 50/125 µm, 2000 m link;
protocols: same as Ethernet port
EtherGate Communicates directly with up to 62 slave devices via
available serial ports
ModemGate Communicates directly with up to 31 slave devices
Firmware characteristics
PE86233
High-speed data recording Up to ½-cycle interval burst recording, stores detailed
characteristics of disturbances or outages
Trigger recording by a user-dened setpoint, or from
external equipment.
Harmonic distortion Up to 63rd harmonic for all voltage and current inputs
Dip/swell detection Analyse severity/potential impact of sags and swells:
- magnitude and duration data suitable for plotting on
voltage tolerance curves
- per phase triggers for waveform recording or control
operations
Instantaneous High accuracy measurements with 1s or 1/2 cycle update
rate for:
- voltage and current
- active power (kW) and reactive power (kvar)
- apparent power (kVA)
- power factor and frequency
- voltage and current unbalance
- phase reversal
Example embedded webserver page (WebMeter) showing
realtime values.
Load proling Channel assignments (800 channels via 50 data
recorders) are congurable for any measureable
parameter, including historical trend recording of
energy, demand, voltage, current, power quality, or any
measured parameter
Trigger recorders based on time interval, calendar
schedule, alarm/event condition, or manually.
Modbus Master Master up to 32 slave devices per serial channel and store
their data at programmable intervals. Use this data to
aggregate and sum energy values and perform complex
totalization.
Waveform captures Simultaneous capture of all voltage and current channels
- sub-cycle disturbance capture
- maximum cycles is 214,000
(16 samples/cycle x 96 cycles, 10 Mbytes memory)
- 1024 samples/cycle
PE86002
Alarms Threshold alarms:
- adjustable pickup and dropout setpoints and time
delays, numerous activation levels possible for a given
type of alarm
- user-dened priority levels
- boolean combination of alarms possible
Advanced security Up to 16 users with unique access rights. Perform resets,
time syncs, or meter congurations based on user
priviledges. Supports protocol lockout and meter access
even logging.
Transformer correction Correct for phase / magnitude inaccuracies in current
transformers (CTs), potential transformers (PTs)
Memory 5 -10 Mbytes (specied at time of order)
Firmware update Update via the communication ports
Display characteristics
Type FSTN transreective LCD
Backlight LED
Sample power quality report. Languages English
133
PLSED309005EN
ION8800
Functions and characteristics (cont.)
Advanced utility metering
Part Numbers
Item Code Description
PE86006
1 Model M8800 ION8800 IEC/DIN 43862 19” rack mount energy and power
quality meter.
Example product part number.
1 Model.
2 Feature set.
3 Memory / form factor.
4 Current Inputs.
5 Voltage inputs.
6 Power supply.
7 System frequency.
8 Communications.
9 Onboard inputs/outputs.
10 Security.
11 Special order.
2Feature Set AClass A power quality analysis, waveforms and transient capture
with 1024 samples/cycle.
BEnergy meter Class S EN50160 power quality monitoring.
CBasic tariff/energy revenue meter with sag/swell monitoring.
3 Memory/Form
Factor
110 MB logging memory, Essailec connectors.
25 MB logging memory, Essailec connectors, with IEC61850
protocol
4Current Inputs C(I1-I3): Congured for 5 A nominal, 10 A full scale, 14 A fault
capture, 0.001 A starting current.
E(I1-I3): Congured for 1 A nominal, 10 A full scale, 14 A fault
capture, 0.001 A starting current.
5Voltage Inputs 0(V1-V3): Autoranging (57-288 VAC L-N or 99-500 VAC L-L)
6Power Supply BSingle phase power supply: 85-240 VAC ±10% (47-63 Hz) or
110-270 VDC.
7 System
Frequency
5Calibrated for 50 Hz systems.
6Calibrated for 60 Hz systems.
8 Communications
module (eld
serviceable)
Z0 No communications module - meter includes Base Onboard I/O
and comms (see below for details).
A0 Standard communications: 1 RS 232/RS 485 port, 1 RS 485
port (COM2) (1).
C1 Standard communications plus 10Base-T Ethernet (RJ45), 56 k
universal internal modem (RJ11).
D1 Standard communications plus 10Base-T Ethernet (RJ45) /
10Base-FL Ethernet Fiber, 56 k universal internal modem
(RJ11).
E0 Standard communications plus 10Base-T Ethernet (RJ45).
F0 Standard communications plus 10Base-T Ethernet (RJ45) /
10Base-FL (ST male Fiber Optic connection).
M1 Standard communications plus 56k universal internal modem
(RJ11).
9Onboard I/O and
communications
(not eld
serviceable, part
of base unit)
ABase option AND 8 Form A digital outputs (2), 1 RS-485 (COM2)
port (1).
BBase Option AND 8 Form A digital outputs (2), 3 digital inputs
(20-56 VDC/AC).
CBase Option AND 8 Form A digital outputs (2), 3 digital inputs
(80-280 VDC/AC).
DBase Option AND 1 IRIG-B time sync port (2), 1 RS-485 port
(COM2), 3 digital inputs (20-56 V DC/AC) (1).
EBase Option AND 1 IRIG-B time sync port (2), 1 RS-485 port
(COM2), 3 digital inputs (80-280 V DC/AC) (1).
10 Security 0 Password protected, no security lock.
1Password protected with security lock enabled.
11 Special Order A None.
CTropicalisation treatment applied.
Related products
RACK-8800-RAW IEC/DIN 34862 19” Rack with female mating voltage/current
and I/O blocks unassembled.
IEC-OPTICAL-PROBE Optional IEC 1107 compliant Optical Probe for use with
ION8800 meters.
BATT-REPLACE-8XXX Replacement batteries for the ION8600 or ION8800,
quantity 10.
ION-SETUP Free conguration software for the ION8800. Ships on a CD.
(1) Channel COM2 is available on the port at the back of the meter OR on the Comm Module
(if installed). You must select which connectors your communications wiring is connected to
during meter setup.
(2) All Onboard I/O and Comms (Base Option) options include: 4 Form C solid-state digital
outputs, 1 Form C mechanical relay output, one IEC 1107 optical communications port,
two IEC 1107 style optical pulsing ports.
134 PLSED309005EN
ION8800
Functions and characteristics (cont.)
Advanced utility metering
Part Numbers (cont.)
ION8800 communications module for eld retrot installations
Item Code Description
P880C
A0 Standard communications: 1 RS-232/RS-485 port, 1 RS-485 port
(COM2) (1).
PE86007
C1 Standard communications plus 10Base-T Ethernet (RJ45), 56k
universal internal modem (RJ11).
D1 Standard communications plus 10Base-T Ethernet (RJ45) /
10Base-FL Ethernet Fiber, 56k universal internal modem (RJ11).
E0 Standard communications plus 10Base-T Ethernet (RJ45).
F0 Standard communications plus 10Base-T Ethernet (RJ45) /
10Base-FL Ethernet Fiber (ST male Fiber optic connection).
M1 Standard communications plus 56k universal internal modem
(RJ11).
Special Order A None.
Optional ION8800 communications module. CTropicalisation treatment applied.
(1) Channel COM2 is available on the port at the back of the meter OR on the Comm Module
(if installed). You must select which connectors your communications wiring is connected to
during meter setup.
Note: The part number above should conform to the following format: P880C A0 A.
135
PLSED309005EN
ION8800
Dimensions and connections
ION8800 dimensions
PE86008
PE86009
ION8800 Essailec rack dimensions
PE86010
Rack mounting the ION8800
PE86011
ION8800 communication module dimensions
PE86012
Advanced utility metering
136 PLSED309005EN
Communication interfaces
and associated services0
Switchboard-data acquisition and monitoring
make it possible to anticipate events. In this way,
they reduce customer costs in terms of
operation, maintenance and investment.
Serial link
With communication technology, it is no longer necessary to be physically present at
the site to access information. Data is transmitted by networks.
In all architectures, the communication interface serves as the link between
the installation devices and the PC running the operating software. It provides
the physical link and protocol adaptation. Adaptation is required because the
communication systems used by the PC (Modbus via RS232 and/or Ethernet) are
generally not those used by the installation devices (e.g. the Modbus protocol via
RS485).
Dedicated application software prepares the information for analysis under the best
possible conditions.
DB111316
Modbus communication architecture.
In addition, an EGX100 in serial port slave mode allows a serial Modbus master
device to access information from other devices across a Modbus TCP/IP network.
DB111317
EGX100
serial slave mode
Modbus master device
Modbus communication across Ethernet network
Communications
137
PLSED309005EN
Communication interfaces
and associated services (cont.)
Ethernet link
Using modern Web technologies, the operator can access information from
monitoring and protection devices using any PC connected to the network, with all
the required security.
The Ethernet EGX100 gateway or the EGX300 integrated gateway-servers provide
connectivity between Modbus RS485 and Ethernet Modbus TCP/IP.
DB111313a
Ethernet communication architecture.
The services available with these technologies considerably simplify the creation,
maintenance and operation of these supervision systems.
The application software is now standardised: the web interface into the system does
not require custom web pages to be created. It is personalised by simply identifying
the components in your installation and can be used as easily as any internet
application.
The rst step in this approach is the EGX300 integrated gateway-server with HTML
pages. Power management software (StuxureWare Power Monitoring Expert and
StruxureWare PowerSCADA Expert), running on a PC, provide broader coverage for
more specic needs.
EGX100 EGX300
Communications
138 PLSED309005EN
Communications Com'X 200 / 210
Energy data loggers
1. Measure 2. Connect 3. Save
Water meters
Gas
meter
Pulse energy meters
Modbus multi-meters
Analogue
sensors
with 4-20 mA
or 0-10 V
adaptor
+ Zigbee
for
EM4300
Internet
Ethernet |
Modbus TCP
Ethernet or
Wi-Fi LAN
Temperature
sensors
Circuit-breakers
Com’X 200/210
Ethernet or Wi-Fi LAN
Modbus Serial Line
Analogue / digital IOs
Zigbee wireless
Wireless Meter
Zigbee
Wireless
transmitters
GPRS
PowerView
Remote
Power
Monitoring
Expert
Main functions
PB114855
Data collector
Collects and stores energy data from up to 64 eld devices, connected to either:
b Ethernet TCP/IP eld network.
b Modbus Serial line network (up to 32 devices).
b Embedded digital and analogue inputs.
“Field devices” consist of :
b PowerLogic devices for power and energy monitoring.
b Masterpact or Compact circuit-breakers for protection and monitoring.
b Acti 9 protection devices, meters, remote controlled switches, etc.
b Water, Air, Gas, Electricity, and Steam consumption meters, from specialized
manufacturers, delivering pulses as per standard (see table next page).
b Environmental sensors such as temperatures, humidity, and CO2 levels in a building,
providing analogue information.
Data logging and storage capabilities include:
b Congurable logging interval, from every minute to once a week.
b Data storage duration of several weeks, depending on quanitity of of collected data.
139
PLSED309005EN
Communications Com'X 200/ 210
Functions and characteristics
Energy Server Com'X 200 data logger
Energy Server Com'X 210 data logger
Data publisher
Batches of collected data periodically transmitted to an Internet server, as:
b XML les, for processing by StruxureWare™ web services, such as Energy
Operation.
b CSV les for viewing in Excel or transformed for upload into programs such as
StruxureWare™ Power Monitoring Expert or any compatible software.
Data publishing function supports 4 transfer protocols over Ethernet or Wi-Fi:
b HTTP.
b HTTPS.
b FTP.
b SMTP.
Additional functions
Gateway
If selected by the user, the Com’X 200/210 can also make all data from connected
devices available in real-time:
b In Modbus TCP/IP format over Ethernet or Wi-Fi.
b For requests by an energy management software.
Modbus packets can be sent from managing software to eld devices through
Modbus serial line or Modbus TCP/IP over Ethernet.
PB112041
PB114328
Com'X 200/210 Commercial reference numbers
Com'X 200 data logger 24 V DC or 230 V AC power supplied EBX200
Com'X 210 data logger 24 V DC power supplied UL rated EBX210
Com'x Wi-Fi USB interface EBXA-USB-WiFi
Com'X GPRS interface SIM card EBXA-GPRS-SIM
Com'X GPRS interface EBXA-GPRS
Com'x External GPRS antenna EBXA-ANT-5M
Com'x Zigbee USB interface EBXA-USB-Zigbee
Please see your Schneider Electric representative for complete ordering information.
140 PLSED309005EN
Communications Com'X 510
Energy server
Pulse energy meters
Modbus multi-meters
Analogue
sensors
with 4-20 mA
or 0-10 V
adaptor
Ethernet or
Wi-Fi LAN
Temperature
sensors
Circuit-breakers
Ethernet or Wi-Fi LAN
Modbus Serial Line
Analogue / digital IOs
Com’X 510
Web browser
Power
Monitoring
Expert
1. Measure 2. Connect 3. Save
Water meters
Gas
meter
Ethernet |
Modbus TCP
Internet
GPRS
PowerView
Remote
Main functions
Data collector
Collects and stores energy data from up to 64 eld devices, connected to either:
b Ethernet TCP/IP eld network.
b Modbus Serial line network (up to 32 devices).
b Embedded digital and analogue inputs.
“Field devices” consist of :
b PowerLogic meters for power and energy monitoring.
b Masterpact, Powerpact, or Compact circuit-breakers for protection and monitoring.
b Acti 9 protection devices, meters, remote controlled switches, etc.
b Water, Air, Gas, Electricity, and Steam consumption meters, from specialized
manufacturers, delivering pulses as per standard (see table at end of this
document).
b Environmental sensors such as temperatures, humidity, and CO2 levels in a
building, providing analogue information.
Data logging and storage capabilities include:
b Data logging period: congurable from every minute to once a week.
b Data storage duration: up to 2 years, depending on quanitity of collected data.
b Able to set time and send reset instructions to eld devices.
Embedded energy management software
The Com’X provides the end-user with immediate visibility into energy consumption
throughout the site. As soon as the Com’X is connected to the Local Area Network
(LAN), several web pages are accessible via any standard web browser, (without
plug-in or additional components).
These web pages display real-time data as it is collected, in easy to understand
tabular and summary formats. In addition, users can get simple analysis of historical
data in bar graph or trending formats.
PB114856
PB114852
Energy dashboard comparing accumulated over time energy
values (partial screen)
141
PLSED309005EN
PB114327
Energy Server Com'X 510 data logger
Additional functions
Data publisher
Batches of collected data can also be periodically transmitted to an Internet server,
as:
b XML les, for processing by StruxureWare™ web services, such as Energy
Operation.
b CSV les for viewing in Excel or transformed or uploading to programs such as
StruxureWare™ Power Monitoring Expert or any compatible software.
Data publishing function supports 4 transfer protocols over Ethernet or Wi-Fi:
b HTTP.
b HTTPS.
b FTP.
b SMTP.
Gateway
b If selected by the user, the Com’X510 can make data from connected devices
available in real time:
b In Modbus TCP/IP format over Ethernet or Wi-Fi.
b For requests by energy management software.
Modbus packets can be sent from managing software to eld devices through
Modbus serial line or Modbus TCP/IP over Ethernet.
Communications Com'X 510
Energy server
PB114854
Raw data and measurements from one eld device (partial
screen)
PB114853
Historical trending comparing multiple devices or multiple
topics (partial screen)
Com'X 510 Commercial reference numbers
Com'X 510 energy server 24 V DC power supplied UL rated EBX510
Com'x Wi-Fi USB interface EBXA-USB-WiFi
Com'X GPRS interface SIM card EBXA-GPRS-SIM
Com'X GPRS interface EBXA-GPRS
Com'x External GPRS antenna EBXA-ANT-5M
Please see your Schneider Electric representative for complete ordering information.
142 PLSED309005EN
Communications Com'X 200/210/510
Connectivity
Connectivity
Modbus SL /RS485 connections to eld devices
b By cable with RJ45 connector.
2 Ethernet ports
b Used to either separate upstream connection from eld devices network or to
daisy chain Ethernet devices.
b RJ45 10/100 Base connectors.
b Static IP address.
Ethernet port #1
b Connection to Local Area Network (LAN).
b PoE Class 3 (802.3af) can act as main/backup power supply for the Com'X.
b DHCP client.
Ethernet port # 2
b Connection to eld devices.
b DHCP cleint or server.
Power supply to analogue and digital outputs
Outputs to supply sensors and inputs when Com’X is supplied through 24 V DC
input on top:
b 12 V DC– 60 mA for digital inputs.
b 24 V DC for analogue inputs.
Compliant with electrical switchboard environment (temperature, electromagnetic
compatibilty).
2 inputs for analogue sensors
b PT100 or PT1000 temperature probes.
b Various sensors (humidity, CO2, etc.) with 0-10 V output.
b Various sensors with 4-20 mA output
6 inputs for dry contact sensors or pulse counters
b Max 25 pulses per second (min duration 20 ms)
b IEC 62053-31 Class A
Optional digital I/O extension module (available Sept 2015)
Wi-Fi USB stick
b As an alternative to publication over Ethernet, connects Com’X to the site Wi-Fi
router for regular data transmission.
b Can also be used for Com'X 510 conguration through one-to-one connection
with laptop or tablet.
b Simply plugs into USB port 2 under front cover.
GPRS modem
b For connection to the data processing server through cellular or user's APN
network.
b Also connect to Schneider Electric's Digital Service Platform.
b Especially suitable for sites with no internet access.
b Simply plugs into dedicated port under the front cover.
GPRS antenna
b Improves GPRS signal strength in case of poor transmission conditions.
b Recommended for Com’X located inside metallic electrical panels.
Zigbee dongle (Com'X 200/210 only - not shown)
For connection to wireless digital enabled eld devices such as PowerLogic
EM4300 meters. Plugs into USB ports.
PowerLogic WT4200 wireless transmitters, connected to Modbus RS485, enables
collecting data also from water, air, gas or steam meters.
PB112047
PB112042 PB112044
PB112045
GPRS antenna
GPRS modem
Wi-Fi USB stick
Connection points
1 Terminal block
2 RJ45 cable
3 Ethernet port #1
4 Ethernet port #2
Power supply to analogue and digital inputs
143
PLSED309005EN
Communications Com'X 200/210/510
Setup and configuration
PB114857
Installation
b DIN rail tting (Front face IP40, terminals IP20).
b Weight 450g.
b Dimensions (HxWxD) 91mm x 144mm x 65.8mm.
Setup and conguration
Connection to LAN
As soon as they are connected to the LAN, it can be detected and assigned an IP
address by DHCP. Your operating system's DPWS feature allows your computer
to automatically recognize the device as Com'X. Embedded web pages are then
immediately accessible by clicking each Com’X device icon or by typing the assigned
IP address into your web browser.
Field device auto-discovery
The user-activated device discovery function automatically identies all eld devices
connected to Modbus SL, Ethernet port or Zigbee dongle.
b Schneider Electric devices display with the product image.
b Other devices appear as “unknown,” allowing the user to manually assign a
device type.
b User can assign their own device types.
Users can complete additional device identication elds, such as circuit ID or
building zone.
Data selection for logging and publication
Web page conguration tabs allow you to congure, in just a few clicks, which
connected eld devices collect and publish data.
Advanced diagnostics and troubleshooting features
b Modbus serial and TCP/IP device statistics.
b Ethernet network statistics.
b Communications check wizard.
b Direct reading of register values from local and remote devices.
Additional features and benets
b Cybersecurity - works well with your cyber security architecture.
b 2 Ethernet ports to separate upstream cloud connection, or to daisy chain with
other Ethernet devices, from eld device network.
b Data storage in case of communications failure.
b Local backup of conguration parameters - back up your system to a USB storage
device and have it available for system restore or to duplicate the conguration on
another box.
When associated with Schneider Electric Services:
b Remotely managed (conguration backup, troubleshooting, parameter setting).
b GPRS SIM contract management (with EBXA-GPRS-SIM).
Device settings page (partial), as displayed after auto-
discovery, enabling user to assign circuit identications and
select data for logging and publication.
Com'X 200/210/510 Environment
Operating temperature
-25º to +60°C (-13º to 140°F) Com'X 200
-25º to +70°C (-13º to 158°F) Com'X 210/510
Storage temperature -40º to +85°C (-40º to +185°F)
GPRS dongle
Operating temperature
-20º to +60°C (-4º to +140°F)
GPRS dongle
Storage temperature
-40º to +85°C (-40º to +185°F)
Wif-Fi dongle
Operating temperature
0º to +50°C (32º to +122°F)
Wi-Fi dongle
Storage temperature
-20º to +80°C (-4º to +176°F)
Humidity 5 to 95% relative humidity (without condensation) at +55ºC
Pollution Class III
Safety standards / regulation
International (CB scheme) IEC 60950
USA UL 508
USA UL 60950 (Com'X 210 and Com'X 510 only)
Canada cUL 60950 (Com'X 210 and Com'X 510 only)
Canada cULus 508
Europe EN 60950
Quality Brands
CE, UL
144 PLSED309005EN
PowerLogic EGX100
Ethernet gateway
Function
The EGX100 serves as an Ethernet gateway for PowerLogic system devices and
for any other communicating devices utilising the Modbus protocol. The EGX100
gateway offers complete access to status and measurement information provided by
the connected devices via PowerLogic software installed on a PC.
PowerLogic software compatibility
PowerLogic software is recommeded as a user interface because they provide
access to all status and measurement information. They also prepare summary
reports. The EGX100 is compatible with:
b StruxureWare Power Monitoring Expert software
b StruxureWare PowerSCADA Expert.
Architecture
Setup
Setup via an Ethernet network
Once connected to an Ethernet network, the EGX100 gateway can be accessed by a
standard internet browser via its IP address to:
b specify the IP address, subnet mask and gateway address of the EGX gateway
b congure the serial port parameters (baud rate, parity, protocol, mode, physical
interface and timeout value)
b create user accounts
b create or update the list of the connected products with their Modbus or
PowerLogic communication parameters
b congure IP ltering to control access to serial devices
b access Ethernet and serial port diagnostic data
b update the rmware
b specify the user language.
Setup via a serial connection
Serial setup is carried out using a PC connected to the EGX100 via an RS232 link.
This setup:
b species the IP address, subnet mask and gateway address of the EGX gateway
b species the language used for the setup session.
Part numbers
Powerlogic EGX100 Schneider Electric
EGX100 EGX100SD, EGX100MG
PowerLogic EGX100
PE86138
PowerLogic
software
Ethernet Modbus TCP/IP
EGX100 gateway
Modbus RS485 serial link
ION6200 PM800 Micrologic Sepam
Communications
145
PLSED309005EN
Characteristics
EGX100
PE86138
Weight 170 g
Dimensions (HxWxD) 80.8 x 72 x 65.8 mm
Mounting Din rail
Power-over-Ethernet (PoE) Class 3
Power supply 24 V DC if not using PoE
Maximum burden 4 W
Operating temperature -25 to 70ºC
Humidity rating 5 to 95 % relative humidity (without condensation) at
+55ºC
Regulatory/standards compliance for electromagenetic interference
Emissions (radiated and conducted) EN55022/EN55011/FCC class A
PowerLogic EGX100 Immunity for industrial environments:
electrostatic discharge EN 61000-6-2
radiated RF EN 61000-4-2
electrical fast EN 61000-4-3
surge EN 61000-4-4
conducted RF EN 61000-4-5
power frequency EN 61000-4-6
magnetic eld EN 61000-4-8
Regulatory/standards compliance for safety
International (CB scheme) IEC 60950
USA UL508/UL60950
Canada cUL (complies with CSA C22.2, no. 60950)
Europe EN 60950
Australia/New Zealand AS/NZS25 60950
Serial ports
Number of ports 1
Types of ports RS232 or RS485 (2-wire or 4-wire), depending on
Protocol Modbus RTU/ASCII, PowerLogic (SY/MAX), Jbus
Maximum baud rate 38400 or 57600 baud depending on settings
Maximum number of connected
devices
32 (directly)
247 (indirectly)
Ethernet port
Number of ports 1
Type of port 10/100 Base TX (802.3af) port
Protocol HTTP, Modbus TCP/IP, FTP, SNMP (MIB II)
Installation
Din rail mounting
PowerLogic EGX100
Ethernet gateway (cont’d)
Communications
72
57.9 80.8 90.7
35
45.2
65.8
2.5
49.5
68.3
146 PLSED309005EN
Communications PowerLogic EGX300
Integrated gateway-server
Function
The EGX300 is an Ethernet-based device providing a simple transparent interface
between Ethernet-based networks and eld devices. These include meter, monitors,
protective relays, trip units, motor controls and other devices that communicate
using ModbusTCP/IP, Modbud, JBUS, or PowerLogic protocol.
The EGX300 can form a simple, scalable web-based monitoring solution providing
real-time data views, on-board data logging/trending, and simple control for eld
devices. The EGX300 helps provide a system solution that can upgrade to include
monitoring software for more advanced data collection, trending, alarm/event
management, analysis and other functions. The EGX300 is compatible with:
b StruxureWare Power Monitoring Expert software
b StruxureWare PowerSCADA Expert.
Architecture
Features
b View real-time and historical information and real-time trending from multiple
locations via any standard web browser
b Automatically detect attached Modbus serial devices for easy setup
b Automatically email, FTP, or HTTP selected logged data to your PC for additional
analysis
b Select the logging intervals and topics you want logged
b Ensures data and system security through password protection and controlled
network access to individual/custom web pages
b Simplies installation by receiving control power through the Ethernet cable
utilising Power-over-Ethernet and offers the option to utilise 24 V DC control
power
b Perform simple control reset commands for supported devices (e.g. min/max,
accumulated energy, etc.)
b Log equipment maintenance activities via the EGX web interface
Part numbers
Powerlogic EGX300 Schneider Electric
EGX300 EGX300
View real-time data and
trend plots through a
simple browser — no
software needed
Ethernet Modbus TCP/IP
EGX100 gateway
Modbus RS485 serial link
ION6200 PM800 Micrologic Sepam
EGX300 integrated
gateway-server
Pull information into web pages
from other PowerLogic
gateways (PM8ECC, EGX100)
EGX300 web page
Trend plots
Data log les
PE86181
PowerLogic EGX300
147
PLSED309005EN
PowerLogic EGX300
Integrated gateway-server (cont’d)
72
57.9 80.8 90.7
35
45.2
65.8
2.5
49.5
68.3
Characteristics
EGX300
Weight 170 g
Dimensions (HxWxD) 80.8 x 72 x 65.8 mm
Mounting Din rail
Power-over-Ethernet (PoE) Class 3
Power supply 24 V DC if not using PoE
Maximum burden 4 W
Operating temperature -25 to 70ºC
Humidity rating 5 to 95 % relative humidity (without condensation) at
Regulatory/standards compliance for electromagenetic interference
Emissions (radiated and EN55022/EN55011/FCC class A
Immunity for industrial
environments:
electrostatic discharge EN 61000-6-2
radiated RF EN 61000-4-2
electrical fast transients EN 61000-4-3
surge EN 61000-4-4
conducted RF EN 61000-4-5
power frequency EN 61000-4-6
magnetic eld EN 61000-4-8
Regulatory/standards compliance for safety
International (CB scheme) IEC 60950
USA UL508/UL60950
Canada cUL (complies with CSA C22.2, no. 60950)
Europe EN 60950
Australia/New Zealand AS/NZS 60950
Serial ports
Number of ports 1
Types of ports RS232 or RS485 (2-wire or 4-wire), depending on settings
Protocol Modbus RTU/ASCII, PowerLogic (SY/MAX), Jbus
Maximum baud rate 38400 or 57600 baud depending on settings
Maximum number of connected
devices
32 (directly)
64 (indirectly)
Ethernet port
Number of ports 1
Type of port 10/100 Base TX (802.3af) port
Protocol HTTP, Modbus TCP/IP, FTP, SNMP (MIB II), BootP
Web server
Memory for logging, custom web
pages and documentation
512 Mb
Installation
Din rail mounting
PowerLogic EGX300
PE86181
Communications
148 PLSED309005EN
Communications ION7550 RTU
Functions and characteristics
PE86117
PowerLogic ION 7550 RTU.
The PowerLogic ION7550 RTU (remote terminal unit) is an intelligent web-enabled
device ideal for combined utilities metering of water, air, gas, electricity and steam
(WAGES). When combined with PowerLogic software, the ION7550 RTU offers a
seamless, end-to-end WAGES metering solution. Featuring a large, high-visibility
display and overall versatility of the PowerLogic system, the ION7550 RTU provides
extensive analogue and digital I/O choices and is a cost-effective dedicated WAGES
solution when compared to a traditional meter. The device automatically collects,
scales and logs readings from a large number of connected meters or transducers
and delivers information to one or more head-end systems through a unique
combination of integrated Ethernet, modem or serial gateways. As part of a complete
enterprise energy management solution, the ION7550 RTU can be integrated with
PowerLogic ION Enterprise software, or other SCADA, information and automation
systems.
Applications
WAGES metering.
Data concentration through multi-port, multi-protocol communications.
Equipment status monitoring and control.
Programmable setpoints for out-of-limit triggers or alarm conditions.
Integrated utility metering with advanced programmable math functions.
Main characteristics
Increase efciency
Reduce waste and optimise equipment operation to increase efciency.
Easy to operate
Screen-based menu system to congure meter settings. Bright LCD display with
adjustable contrast.
Integrate with software
Easily integrated with PowerLogic or other energy management enterprises,
including SCADA systems.
Transducer and equipment condition monitoring
Versatile communications, extensive I/O points, clock synchronization, event
logging and sequence of events recording capabilities for transducer and equipment
condition and status monitoring at utility substations.
Set automatic alarms
Alarm setpoint learning feature for optimum threshold settings.
Up to 10 Mbytes of memory
For archiving of data and waveforms.
Notify alarms via email
High-priority alarms sent directly to the user’s PC. Instant notication of power quality
events by email.
Modbus Master functionality
Aggregate and store data from downstream Modbus devices using serial or Ethernet
connections.
Part numbers
ION7550 RTU
ION7550 M7550
149
PLSED309005EN
Communications ION7550 RTU
Functions and characteristics (cont.)
PE86124
PowerLogic® ION7550 RTU.
Selection guide ION7550 RTU
Data recording
Min/max of instantaneous values b
Data logs b
Event logs b
Trending b
SER (Sequence of event recording) b
Time stamping b
GPS synchronisation (1 ms) b
Memory (in Mbytes) 10
Display and I/O
Front panel display b
Pulse output 1
Digital or analogue inputs(max) 24
Digital or analogue outputs (max, including pulse output) 30
Communication
RS 485 port 1
RS 485 / RS 232 port 1
Optical port 1
Modbus TCP Master / Slave (Ethernet port)
Modbus RTU Master / Slave (Serial port)
Ethernet port (Modbus/TCP/IP protocol) 1
1 I/O expansion card.
2 Digital inputs.
3 Analogue inputs.
4 Analogue outputs.
5 Communications card.
6 Power supply.
7 Form C digital outputs.
8 Digital inputs.
9 Form A digital outputs.
Ethernet gateway (EtherGate) 1
Alarms (optional automatic alarm setting b
Alarm notication via email (Meterm@il) b
HTML web page server (WebMeter) b
Internal modem 1
Modem gateway (ModemGate) b
DNP 3.0 through serial, modem, and I/R ports b
150 PLSED309005EN
Communications ION7550 RTU
Functions and characteristics (cont.)
PE86117
Electrical characteristics
Data update rate 1/2 cycle or 1 second
Power supply AC 85-240 V AC ±10% (47-63 Hz)
DC 110-300 V DC ±10%
DC low voltage (optional) 20-60 V DC ±10%
Ride-through time 100 ms (6 cycles at 60 Hz) min. at 120 V DC
Burden Standard: typical 15 VA, max 35 VA
Low voltage DC: typical 12 VA, max 18 VA
Input/outputs(1) Standard 8 digital inputs (120 V DC)
3 relay outputs (250 V AC / 30 V DC)
4 digital outputs (solid state)
Optional 8 additional digital inputs
4 analogue outputs, and/or 4 analogue inputs
Mechanical characteristics
Weight 1.9 kg
IP degree of protection (IEC 60529) IP52
PowerLogic ION7550 RTU. Dimensions Standard model 192 x 192 x 159 mm
TRAN model 235.5 x 216.3 x 133.1 mm
Environmental conditions
Operating
temperature
Standard power supply -20 to +70ºC
Low voltage DC supply -20 to +50ºC
Display operating range -20 to +70ºC
Storage
temperature
Display, TRAN -40 to +85ºC
Humidity rating 5 to 95% non-condensing
Installation category III (2000m above sea level)
Dielectric withstand As per EN 61010-1, IEC 62051-22A(2)
Electromagnetic compatibility
Electrostatic discharge IEC 61000-4-2
Immunity to radiated elds IEC 61000-4-3
Immunity to fast transients IEC 61000-4-4
Immunity to surges IEC 61000-4-5
Conducted and radiated emissions CISPR 22
Safety
Europe IEC 61010-1
(1) Consult the ION7550 / ION7650 installation guide for complete specications.
(2) IEC 62051-22B with serial ports only.
151
PLSED309005EN
Communications ION7550 RTU
Functions and characteristics (cont.)
Communication
RS 232/485 port (1) Up to 115,200 bauds (57,600 bauds for RS 485), ION,
DNP 3.0, Modbus, GPS, EtherGate, ModemGate,
Modbus Master
RS 485 port (1) Up to 115,200 bauds, ION, DNP 3.0, Modbus, GPS,
EtherGate, ModemGate, Modbus Master
Infrared port(1) ANSI type 2, up to 19,200 bauds, ION, Modbus, DNP 3.0
Ethernet port 10BaseT, 100BaseTX. RJ45 connector, 10/100 m link
Fibre-optic Ethernet link 100Base FX, SC duplex connector, 1300 nm, FO
multimode with gradient index 62.5/125 µm or 50/125
µm, 2000 m link
Protocol ION, Modbus, Modbus Master, TCP/IP, DNP 3.0, Telnet
EtherGate Communicates directly with up to 62 slave devices via
available serial ports
ModemGate Communicates directly with up to 31 slave devices
WebMeter 5 customisable pages, new page creation capabilities,
HTML/XML compatible
Firmware characteristics
High-speed data recording Down to 5ms interval burst recording, stores detailed
characteristics of disturbances or outages. Trigger
recording by a user-dened setpoint, or from external
equipment.
Load proling Channel assignments (800 channels via 50 data
recorders) are congurable for any measurable
parameter. Trigger recorders based on
time interval, calendar schedule, alarm/event condition,
or manually.
Trend curves Access historical data at the front panel. Display, trend
and continuously update historical data with date and
timestamps for up to four parameters simultaneously.
Alarms Threshold alarms:
adjustable pickup and dropout setpoints and time delays,
numerous activation levels possible for a given type of
alarm
user-dened priority levels
boolean combination of alarms is possible using the
operators NAND, OR, NOR and XOR
Advanced security Up to 16 users with unique access rights. Perform
resets, time syncs, or meter congurations based on
user privileges
Memory 5 to 10 Mbytes (specied at time of order)
Firmware update Update via the communication ports
Display characteristics
Integrated display Back lit LCD, congurable screens
Languages English
(1) All the communication ports may be used simultaneously.
152 PLSED309005EN
Communications ION7550 RTU
Functions and characteristics (cont.)
Part numbers
PE86118
5N 9
M
4
Item Code Description
1 Model 7550 ION7550 device
2Form Factor A0 Integrated display with front optical port, 5 MB logging memory,
and 512 samples/cycle resolution.
Sample ION7550 RTU part number. B0 Integrated display with front optical port, 10 MB logging memory,
and 512 samples/cycle resolution.
T0 Transducer (no display) version, with 5 MB logging memory.
U0 Transducer (no display) version, with 10 MB logging memory.
3RTU option N9 RTU option
4Power Supply BStandard power supply (85-240 VAC, ±10%/47-63 Hz / 110-330
VDC, ±10%)
CLow voltage DC power supply (20-60 VDC)
5Internal use 9This eld for internal use only
6 Communications A0 Standard communications (1 RS-232/RS-485 port, 1 RS-485
port). Integrated display models also include 1 ANSI Type 2
optical communications port.
C1 Standard communications plus 10BASE-T/100BASE-TX
Ethernet (RJ-45), 56k universal internal modem (RJ-11).
Ethernet, modem gateway functions each use a serial port.
D7 Standard comms plus 10BASE-T/100BASE-TX Ethernet (RJ-
45) and 100BASE-FX Ethernet Fiber, 56k universal internal
modem (RJ-11). Ethernet and modem gateway functions each
use a serial communications port.
E0 Standard communications plus 10BASE-T/100BASE-TX
Ethernet (RJ-45). Ethernet gateway function uses serial port.
F1 Standard communications plus 10BASE-T/100BASE-TX
Ethernet (RJ-45) and 100BASE-FX (SC ber optic connection).
Ethernet gateway uses a serial port.
M1 Standard communications plus 56k universal internal modem
(RJ-11). Modem gateway uses serial communications port.
7 I/O A Standard I/O (8 digital inputs, 3 Form C relays, 4 Form A solid-
state outputs)
DStandard I/O plus Expansion I/O card (8 additional digital inputs
& four 0 to 1 mA analogue inputs)
EStandard I/O plus Expansion I/O card (8 additional digital inputs
& four 0 to 20 mA analogue inputs)
HStandard I/O plus Expansion I/O card (8 additional digital inputs
& four -1 to 1 mA analogue outputs)
KStandard I/O plus Expansion I/O card (8 additional digital inputs
& four 0 to 20 mA analogue outputs)
NStandard I/O plus Expansion I/O card (8 additional digital inputs
& four 0 to 20 mA analogue inputs and four 0 to 20 mA outputs)
PStandard I/O plus Expansion I/O card (8 additional digital inputs
& four 0 to 1 analogue inputs and four -1 to 1 mA analogue
8 Security 0 Password protected, no hardware lock
9Special Order A None
CTropicalisation treatment applied
153
PLSED309005EN
Communications ION7550 RTU
Functions and characteristics (cont.)
Communications Card
PE86021
P
C 1
Example order code. Use this group of codes when ordering the
PowerLogic ION7550 RTU communication or I/O card.
Item Code Description
1 Comm card P765C ION7550 RTU communication card for eld retrot installations
2 Type A0 Standard communications (1 RS-232/RS-485 port, 1 RS-485
port). Front optical port support for meters with integrated
display.
C1 Standard communications plus 10BASE-T/100BASE-TX
Ethernet (RJ-45), 56k universal internal modem (RJ-11; the
modem port is shared with the front optical port). Ethernet and
modem gateway functions each use a serial communications
port.
1 Communications or I/O card.
2 Type.
3 Special order.
D7 Standard communications plus 10BASE-T/100BASE-TX
Ethernet, 100BASE-FX Ethernet Fiber, 56k universal internal
modem (RJ-11; the modem port is shared with the front optical
port). Ethernet and modem gateway functions each use a serial
communications port.
E0 Standard communications plus 10BASE-T/100BASE-
TX Ethernet. Ethernet gateway function uses a serial
communications port.
F1 Standard communications plus 10BASE-T/100BASE-
TX Ethernet, 100BASE-FX Ethernet Fiber (SC ber optic
connection). Ethernet gateway function uses a serial
communications port.
M1 Standard communications plus 56k universal internal modem
(RJ-11; the modem port is shared with the front optical port).
Modem gateway function uses a serial communications port.
3Special order A None
CTropicalization treatment applied
154 PLSED309005EN
Communications ION7550 RTU
Functions and characteristics (cont.)
Part numbers (cont’d)
Input/Output expansion card
Item Code Description
I/O card P760A Expansion I/O for eld retrot installations.
Type D Expansion I/O card with eight digital inputs, four 0 to 1 mA
analogue inputs
EExpansion I/O card with eight digital inputs, four 0 to 20 mA
analogue inputs
HExpansion I/O card with eight digital inputs, four -1 to 1 mA
analogue outputs
KExpansion I/O card with eight digital inputs, four 0 to 20 mA
analogue outputs
NExpansion I/O card with eight digital inputs, four 0 to 20 mA
analogue inputs & four 0 to 20 mA outputs
PExpansion I/O card with eight digital inputs, four 0 to 1 analogue
inputs and four -1 to 1 mA analogue outputs
Special Order A None
CTropicalization treatment applied
OpenDAC rack, controllers, power supply
70LRCK16-48 OpenDAC rack. Holds up to 8 OpenLine modules to provide up
to 16 I/O points. Requires communications controller
72-MOD-4000 OpenDAC OpenDAC RS-485 serial module. Communications
controller for use in a Modbus RTU network. Supports up to 2
70LRCK16-48 OpenDAC racks
72-ETH-T000 OpenDAC Ethernet network module for use on an Modbus/TCP
Ethernet network. Supports up to 2 OpenDAC racks
PS-240-15W 85-264VAC/110-370VDC 15 Watt power supply. Required for
applying power to the racks and controllers
OpenLine digital I/O modules
70L-IAC digital input, 120VAC
70L-IACA digital input, 220VAC
70L-IDC digital input, 3-32VDC
70L-IDCB digital input, fast switching
70L-IDCNP digital input, 15-32VAC/10-32VDC
70L-IDC5S dry contact closure-sensing DC input
70L-ISW input test module
70L-OAC digital output, 120VAC
70L-OACL digital output, 120VAC inductive loads
70L-OACA digital output, 220VAC
70L-OACAL digital output, 220VAC inductive loads
70L-ODC digital output, 3-60VDC fast
70L-ODCA digital output, 4-200 VDC
70L-ODCB digital output, fast switching
70L-ODC5R digital output, dry contact
OpenLine analogue I/O modules
73L-II020 analogue input, current, 0-20mA
73L-II420 analogue input, current, 4-20mA
73L-ITCJ analogue input, temperature, J-type TC
73L-ITCK analogue input, temperature, K-type TC
73L-ITCT analogue input, temperature, T-type TC
73L-ITR100 analogue input, temperature, RTD
73L-ITR3100 analogue input, temperature, 3wire RTD
73L-ITR4100 analogue input, temperature, 4wire RTD
73L-IV1 analogue input, voltage, 0-1VDC
73L-IV10 analogue input, voltage, 0-10VDC
73L-IV10B analogue input, voltage, -10 to 10VDC
73L-IV100M analogue input, voltage, 0-100VDC
73L-IV5 analogue input, voltage, 0-5VDC
73L-IV5B analogue input, voltage, -5 to 5VDC
73L-IV50M analogue input, voltage, 0-50mV
73L-OI020 analogue output, current, 0-20mA
73L-OI420 analogue output, current, 4-20mA
73L-OV10 analogue output, voltage, 0-10VDC
73L-OV10B analogue output, voltage, -10 to 10VDC
73L-OV5 analogue output, voltage, 0-5VDC
73L-OV5B analogue output, voltage, -5 to 5VDC
155
PLSED309005EN
Communications ION7550 RTU
Dimensions and connection
ION7550 RTU dimensions
PE86022
PE86023
Front-panel mounting
PE86027
Power supply
PE86123
Note: the current and voltage terminal strip (I52, I51, I42, I41, I32, I31, I22,
I21, I12, I11, V4, V3, V2, V1, Vref) is not present on the RTU.
Protection
(3A)
L/+ N/-
Power supply
Fuse for N/- required if
neutral is ungrounded
Connect G terminal
to ground for AC
power source
PLSED309005EN
156
StruxureWare
Power Management Software
Monitoring software
A choice of powerful, effective solutions
StruxureWare™ power management software provides a complete power
management supervisory interface that gives you give you access from anywhere to
your entire electrical network. It helps you maximise energy efciency and cut
energy-related costs, avoid power-quality related equipment failures and downtime,
and increase network-wide operational efciency. It is ideal for all power critical
facilities, including industrial operations, large commercial and institutional buildings,
data centres, healthcare sites, and utilities.
The software converts energy-related data into timely, accurate information for you
to act on. Track real-time power conditions, analyze power quality and reliability, and
respond quickly to alarms to avoid critical situations. Our power management
software provides extensive analysis and reporting tools, intuitive visualization and
control interfaces, and exible, scalable architectures that can meet your unique
needs today and continue to do so well into the future. The depth of different
offerings makes it easy to match a product to your goals, your business and your
budget.
Extensive reach and flexibility
Software forms an important part of your overall energy efciency and reliability
solutions from Schneider Electric. Power management software can grow with your
business, giving you the level of energy intelligence and control you need to reduce
energy consumption and costs, minimise environmental impacts, prolong equipment
life, and assure power availability, uptime and safety.
Each product collects energy-related data from a variety of sources, including
PowerLogic or third-party meters and sensors. Some products offer integration with
other Schneider Electric or third-party automation systems, and other energy-
relevant information feeds.
Object-based, standard graphics and symbols provide operators with an interactive
and user-friendly interface. Intuitive commands and controls increase efciency of
operators to interact with the system interface.
StruxureWare power management software controls your system with high reliability,
performance and data integrity through the use of advanced architectures, such as
hot/warm redundant I/O device congurations, self-healing ring communications,
and primary and standby server congurations. Comprehensive user-based security
is integrated into all interface elements, ensuring a secure control system.
bMeet or exceed power reliability requirements within budget constraints.
bAvoid or mitigate power quality issues to reduce duration or eliminate outages.
bEnable proactive system maintenance to avoid equipment failures.
bComply with corporate or regulatory energy standards like ISO 50001.
bEnsure the comfort and safety of staff and equipment.
System requirements
Whether you’re building a new system or enhancing an existing operation, a
Schneider Electric representative will advise you on complete system requirements
and commissioning information for StruxureWare power management software.
StruxureWare Power Management software
Dashboard sample
PLSED309005EN 157
StruxureWare
Power Management Software
Monitoring software
Applications for power critical facilities
Category Application
Energy efciency
& cost
Energy usage analysis
Cost allocation
Procurement optimisation
Peak demand reduction
Demand response and curtailment
Power factor correction
Power availability
& reliability
Electrical distribution (ED)
Power quality analysis and compliance
ED commissioning, monitoring, and troubleshooting
ED alarming and events
Asset management
Capacity planning
Generator monitoring
Breaker aging management
UPS battery monitoring
Typical applications
StruxureWare power management software has many applications:
bMonitor the facility electrical network and verify reliable operation.
bImprove response to power-related events and restore operations quickly.
bAnalyze and isolate the source of power quality problems.
bAnalyze energy use to identify waste and reduce cost.
bEstimate utility bills to verify accuracy and identify errors.
bAllocate energy costs to departments to drive accountability and awareness.
bReduce peak demand surcharges and power factor penalties.
bIdenty excess capacity in existing infrastructure and avoid over-building.
bSupport proactive maintenance to prolong asset life.
bNetwork protection and control.
bOperate distribution network safely and reliably.
bImprove continuity of electrical service.
bEquipment monitoring and control.
bEnergy availability and reliability.
bVerify the reliable operation of equipment.
bSupport proactive maintenance to prolong asset life.
For electric utilities:
bImprove T&D network reliability.
bEnhance substation automation.
bMaximise the use of existing infrastructure.
bVerify compliance with new power quality standards.
bAnalyse and isolate the source of power quality problems.
bHelp customers manage reliability using operational and power quality data.
PLSED309005EN
158
StruxureWare
Power Management Software
PB111281
Scalable, exible architecture
Functional components
Provides operators with a rich environment to view and navigate real-time displays of
measurements and status indicators; perform power quality and reliability analysis;
historical trending; alarms; and manual control. This software offers secure,
operator-dedicated, multi-user data and control access through a local server
interface, full control client and also via web clients.
Web Clients
Access power monitoring system from anywhere on your network using a web
browser. Day-to-day functionality including system status, alarm response, or viewing
dashboards. Web client provides authenticated access to common functions:
bDiagrams – navigate network displays to check system status and analyze trends.
bTables – quickly compare multiple devices in your network in real-time.
bReports – generate or edit historical reports for energy cost, consumption, and
power quality.
bAlarms – quickly identify alarm states in your system and investigate root causes.
bDashboards – share information from your power monitoring system with any occupant.
Engineering Workstations
Client software gives engineers and power users access to administrative and
conguration functions of the software, and real-time display, control, and historical
analysis functions.
bBuild and edit custom graphical displays to represent your facility. One-line
diagrams, campus maps, equipment plan views and mimic diagrams are easily
created using Vista graphical objects and imported graphic les.
bUse the designer interface to program ION devices and create system
applications with ION Technology and Virtual ION ProcessorsReporter - generate or
edit historical reporst for energy cost, consumption, and power quality.
Data acquisition and management
bCommunicate with over 300 different powerlog and third-party meters.
bScale from 1 to 1000s of devices.
bPerform advanced logic and arithmetic operations on real-time and historical data.
bUse web services to interoperate and integrate with other software platforms.
Dashboard - Energy Summary (sample)
EB100264
Easily edit pages to depict your entire system
Load proles, comparisons, and energy allocation
EB100283
PLSED309005EN 159
Functions
StruxureWare power management software offers a wide range of
functions:
bData acquisition and integration.
bReal-time monitoring.
bTrend analysis.
bPower quality analysis.
bAlarms and events.
bReporting.
bDashboards.
bManual and automated control.
Data acquisition and integration
Integrate WAGES (Water, Air, Gas, Electricity, Steam) metering. Native,
out-of-the-box support for dozens of devices (See Supported Devices section for
details).
bEnables access to real-time and timestamped historical meter data, control of
on-board relays and digital outputs, and server time synchronization.
Communicate over Internet, Ethernet, wireless.
bInterface with third-party meters, transducers, PLCs, RTUs and power
distribution or mitigation equipment through Modbus or OPC.
bAdd and congure direct communications with remote devices over Modbus
RTU or Modbus TCP protocols using easy-to-use device templates.
The scalable platform enables remote device and user client addition as needs
grow while maintaining original investment. Integrate other energy management
or automation systems (e.g. SCADA, BAC, DCS, ERP) through ODBC, XML,
OPC, email, FTP, CSV and PQDIF compliance; integrate with web services
through XML.
Real-time monitoring
View the status of your electrical network from any workstation:
bSee numeric values, status indicators, gauges, and trends, all with intuitive
graphical navigation.
bExtend comprehensive out-of-the-box displays and create custom graphical
diagrams to represent your facility; one-line diagrams, campus maps, equipment
plan views and mimic diagrams can be created using embedded graphical
objects and imported graphic les.
bQuickly compare multiple devices in your network in real-time in a tabular
display.
bChoose from a library of pre-built tables, or create your own. Save your
favorites for quick access later.
Trend analysis
bTrend parameters to reveal demand peaks and track system-wide energy
costs.
bGraph any combination of measured parameters.
bPlot time-series or scatter charts.
bPerform calculations, obtain statistics, and display historical data.
bIdentify dangerous trends and redistribute loads.
bOptimise network capacity and avoid over-building.
bView operating parameters and determine when maintenance is required.
bAvoid peak demand surcharges and power factor penalties.
StruxureWare
Power Management Software
Equipment Status example
Consumption details by area and load type
PE86178
EB100266EB100265
ECS Engineer workstation
EGX 400
PLC
PLC Islanding
PLC
Clock
EGX 400
Remote I/O
rack
EGX 400
Master clock
Ethernet optical ring
Optical converter
Optical converter
Compatible devices
Compatible devices
Compatible devices
Optical converters
ECS Operator workstation
Redundant ECS server
PLSED309005EN
160
StruxureWare
Power Management Software
Power quality analysis
StruxureWare power management software allows continuous, wide-area
monitoring and data capture for power quality and reliability conditions.
bPower quality events automatically detected by PQ-capable metering devices are
uploded to the system automatically. Analyze waveforms to determine source and
cause of issue.
bDetermine if power quality events are upstream or downstream (using PowerLogic
meters with Disturbance Direction Detection feature).
bIEC 61000-4-30 and EN50160 compliance reporting veries power quality
performance to international standards and allows you to quickly review power
quality indices as numeric charts or graphic proles (using PowerLogic meters to
support compliance monitoring).
bDisplay harmonic histograms, odd/even harmonics, THD, K-factor, crest factor,
phasor diagrams, and symmetrical components.
bPlot waveforms of up to many seconds in duration, with overlays that correlate
phase-to-phase relationships between voltages, currents, and cascading failures.
bPlot sags, swells, short duration transients and other disturbance events on
industry-standard voltage tolerance curves, including ITIC (CBEMA) and SEMI.
bDisplay for any event a list of associated time-stamped incidents, then click on any
incident to see more detailed information.
Alarms and events
Receive alerts to outages or impending problems that could lead to equipment
stress, failures, or downtime.
bQuickly lter on active or unacknowledged alarms.
bAcknowledge alarms from anywhere in your facility.
bTrigger on complex conditions.
bLog all relevant data sequence of events for diagnosis.
bFlag and avert potential problems.
bAlert key personnel 24/7.
bOptimise maintenance scheduling.
b Easily discriminate between alarm criticality levels.
b High speed alarm response.
b Organise, lter and print by any alarm property. Congure specic alarm
occurrences to change symbol color or ash an icon on a page.
b View the ve most recent alarms from every page, providing detailed information
in easy-to-understand formats.
b Event log for all PC-based and on-board eld events, alarms.
b Easily congure to annunciate based on alarm type.
Dashboards
Create engaging dashboard displays of your power monitoring system information
and easily share information with anyone in your facility.
bMake power monitoring information visible and engaging.
bPromote education and drive behaviour.
bDisplay as an interactive kiosk on corporate intranet or on wall-mounted display.
bReplace hard to maintain home-grown portals and dashboards.
bChart or trend any quantity in your power monitoring database.
bSimply convert into other units (e.g. dollars, emissions, normalizations, etc.).
bCompare multiple time-ranges.
bShow impact of temperature, occupancy, or production values on energy usage.
bCreate eye-catching backgrounds to enhance presentation value.
bUser authentication for conguration, and both authenticated and unauthenticated
modes available for display.
EB100268EB100269EB100270
Applications allow users to easily create trend plots and
analyze historical data.
Users can view and analyze waveforms captured by
devices.
Load prole dashboard (sample)
PLSED309005EN 161
StruxureWare
Power Management Software
Reporting
Reports - generate or edit historical reports for energy cost, consumption, and power
quality (requires Microsoft SQL Server Standard Edition).
bPowerful, intuitive reporting options let users see critical information exactly how,
where, and when they need it.
bReports can be generated manually and saved as Excel, HTML and other formats
or scheduled to automatically distribute to a printer or via email.
Conguration tools
Our power management software is supplied with a package of conguration tools
designed to make set up uniquely easy and quick.
b Designed to help make project set up and network conguration fast and easy.
b Provides standard device types and their associated proles and allows engineers
to easily customise the proles of the devices specic to the project.
b Standardized tags per device prole (congurable), XML le.
b Standard interface for quick database generation:
v Instantiation of devices, on a per object basis.
v Creates tags, trends, alarms and events when devices are added to system.
v Batch editing supported by automation interface.
Manual and automated control
bPerform fast, manual control operations by clicking on-screen trigger buttons, and
operate remote breakers, relays, and other power distribution and mitigation
equipment.
bPerform manual or setpoint-triggered functions.
bCoordinate control of multiple loads, generators, relays, etc.
bSupport energy-saving applications.
bManage distributed energy assets.
bAutomate substations & reduce service time.
Interoperability
bIntegrate all energy management and automation systems (SCADA, BAC, DCS,
ERP, etc.)
bShare data with third-party SCADA, automation, and accounting systems.
bComply with ODBC, OPC, and PQDIF standards.
Patented ION technology
StruxureWare power management software and a variety of PowerLogic ION
metering products feature the unique ION architecture. This modular, exible
architecture offers extensive customisation of functionality using a simple building
block approach. The technology uniquely addresses advanced monitoring and
control applications and adapts to changing needs, avoiding obsolescence.
Global solutions
Software is available in many languages - English, French, Spanish, German, and
Chinese. Contact your Schneider Electric representative.
EB100280 EB100279
StruxureWare provides many different report templates to
allow users to easily display and deliver the information they
need .
Power Quality Summary Report example
© 2015 - Schneider Electric - All rights reserved
Schneider Electric Industries SAS
35, Rue Joseph Monier,
CS 30323
F - 92506 Rueil Malmaison Cedex
RCS Nanterre 954 503 439
Capital social 896 313 776
www.schneider-electric.com
PowerLogic Catalogue
PLSED309005EN
As standards, specifications and designs develop from time to time, please ask
for confirmation of the information given in this document.
Design: Schneider Electric
Photos: Schneider Electric
05-2015

Navigation menu