100147 Catalog 1

337389-Catalog 337389-Catalog 337389-Catalog 782001 Batch7 unilog cesco-content

100147-Catalog 100147-Catalog 100147-Catalog 068938 Batch6 unilog cesco-content

100147-Catalog 100147-Catalog 100147-Catalog 782001 Batch6 unilog cesco-content

2014-07-30

: Pdf 100147-Catalog 1 100147-Catalog_1 782001 Batch6 unilog

Open the PDF directly: View PDF PDF.
Page Count: 548

Download100147-Catalog 1
Open PDF In BrowserView PDF
The

ADVISOR

Fuses | Fuse Blocks & Holders | Power Distribution Blocks | Surge Protection Devices
Circuit Protection Accessories | Disconnect Switches | Heatsinks & Cooling Systems | High Power Switches

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

The Advisor

More Products. More Resources. More For You Than Ever Before.
A Different Kind of Advisor
A lot has changed with this latest edition of the Advisor. You’ll find 756 additional
products including, high power switches, heatsinks and cooling, medium voltage
fuses, surge protection devices, and our new Helio Protection fuse line.
There’s a new Resources & Tools section with time-saving services like electrical
services and the Fuse Control™ program, as well as handy tools like SelectA-Fuse software®, Protection Intelligence Quotient Quizzes, and R-Tools®, our
online 3D heatsink thermal modeling tool.
In an effort to produce a more “green” catalog, we’ve done more with less. There
are more products, but fewer pages. Product performance data (time current
curves, peak let thru data, etc.) has been moved out of the catalog and onto our
website. Our goal was two-fold, to print a leaner catalog and provide a method for
ensuring that you have the most up-to-date data available at any given time. As
part of our on-going sustainability initiatives we also took great care in selecting
a more environmentally-friendly paper stock. The results ─ a more streamlined,
information packed catalog than ever before!

Your Trusted Advisor
You’ve come to rely on the Advisor for advice. Advice on
choosing the right fuse for the application. On coordinating
it with upstream and downstream devices. On heatsink
configurations. On complying with international standards. On
selecting the right surge protection. And on a whole range of
other complicated electrical protection and business issues.

A Team of Advisors Dedicated to Your Field

Contact Us

You can rest easy knowing a team of experts is ready to help you work through
the application challenges you face. Our experts have extensive experience in

T 978.462.6662

product-specific disciplines including:

F 978.462.0181

Power Controls  LV/MV motor control centers, control panels, HVAC, and

info.nby@mersen.com

material handling

us-ferrazshawmut.mersen.com

Power Electronics  Drives, soft starters, UPS, rectifiers, inverters, frequency
converters, induction heating, rail propulsion, and welding
Power Transmission & Distribution  Switchgear, switchboards, panelboards,
load centers, PF correction, surge protection, rail current collection, rail grounding
Power Low Voltage Distribution  Substations, transformers, transmission
lines, PF correction

Expert Advice When You Need It
Mersen expertise extends out into the field and into the world at large. For a
complete listing of our North American sales offices, global manufacturing, and
technical services support contacts visit us at:
us-ferrazshawmut.mersen.com.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Table of Contents
Product Quick Selector

Typical applications & recommended
product types .............................................................3

A
Amp-Trap® 2000 Fuses

Class J / AJT........................................................... A2
Class L / A4BQ........................................................ A4
Class RK1 / A2D-R & A6D-R.................................. A6
Class CC / ATDR.................................................... A8
Class CC / ATQR.................................................. A10

B
North American Power Fuses

Class RK5 / Tri-Onic® TR & TRS............................ B2
Class RK5 / Tri-Onic® TRS-RDC............................ B4
Class J / Amp-Trap® HSJ........................................ B6
Class J / Amp-Trap® A4J......................................... B8
Class L / Amp-Trap® A4BY.................................... B10
Class L / Amp-Trap® A4BT.................................... B12
Class T / Amp-Trap® A3T & A6T........................... B14
Class RK1 / Amp-Trap® A2K & A6K...................... B16
Class G / Amp-Trap® AG....................................... B18
Class CC / Amp-Trap® ATMR............................... B19
Class K-5 / One-time OT & OTS.......................... B20
Class H / Renewable RF & RFS.......................... B22
Plug Fuses............................................................ B24

C
Midget, Miniature & PC Mount Fuses
Midget
ATQ Time-Delay......................................................C2
ATM Fast-Acting..................................................... C3
TRM Time-Delay.....................................................C4
OTM Fast-Acting.....................................................C5
DCT Special Purpose.............................................C6
FSM Multi-Meter Fuse............................................C7
GGU Fast-Acting.....................................................C8
GFN Indicating Time-Delay....................................C9
SBS Fast-Acting....................................................C10
PC Mount
PCF; PCS; PCT.................................................... C11
Miniature
GSA/GSA-V; GDL/GDL-V....................................C15
GGC/GGC-V; GGM/GGM-V.................................C16
GGA/GGA-V; GSC/GSC-V...................................C17
GSB/GSB-V; GDG/GDG-V...................................C18
GSD/GSD-V; GSF/GSF-V....................................C19
GGX; GAB; GSR-V...............................................C20
SMG/SMG-V; STG/STG-V...................................C21
Radial Lead Micro Fuses MRF, MRT...................C22
SFRT; SFRB; SFRG; FSFE, SFRU .....................C23
SLR, SMF, SHR....................................................C24
Automotive Fuses AF, AF2, AF3, AFH20, AFH30,
AF2H30, AF3H60..................................................C26

D
Semiconductor Fuses

Amp-Trap® Form 101 / A15QS...............................D2
Amp-Trap® Form 101 / A30QS...............................D4
Amp-Trap® Form 101 / A50QS...............................D6
Amp-Trap® Form 101 / A50P..................................D8
Amp-Trap® Form 101 / A60Q................................D10
Amp-Trap® Form 101 / A60X................................ D11
Protistor® / A070gRB.............................................D13
French Cylindrical / A70QS...................................D14
Amp-Trap® Form 101 / A70QS.............................D16
Amp-Trap® Form 101 / A70P................................D18
Amp-Trap® Form 101 / A70Q................................D20
Amp-Trap® Form 101 / A100P..............................D22
Amp-Trap® Form 101 / A120X..............................D24
Amp-Trap® Form 101 / A150X..............................D25
DIN 6,9gRB-URB;6,6gRB-URB............................D26
British Standard....................................................D31
PSC Square Body 690/700V................................D44
PSC Square Body 1250/1300V............................D55
French Cylindrical.................................................D63

E
Medium Voltage Fuses & Accessories
Transformer Protection
Amp-Trap® CS-3 & 9F60/9F62 Series.................... E2
Amp-Trap® & 9F62 Bolt-In Series......................... E12
Amp-Trap® CL-14 Series...................................... E16
Motor Protection
Amp-Trap® & 9F60 Series.................................... E21
Amp-Trap® Bolt-in Series...................................... E27
Amp-Trap® DIN-style Series................................. E30
Potential Transformer Protection
Amp-Trap® & 9F60 Series PT Fuses ................... E32
Capacitor Protection
Amp-Trap® & 9F60 Series.................................... E36
Distribution Transformer Protection
Sure Guard 9F59U Series ETP............................ E44
IEC Standard Back-up Fuse Links
IEC Standard Back-up Fuse-Links....................... E48
Accessories
Type EK 9F61 Series............................................ E53

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

F
International Fuses
EURO/IEC Fuses
gl-gG, aM................................................................ F2
D0 type (NEOZED)................................................. F7
D type (DIAZED)....................................................F11
NH Dimension / gl-gG, aM.................................... F15
Canadian Fuses
Class C.................................................................. F20
Class CA & CB, CN/CNS...................................... F22
HRCII NIT/NS....................................................... F23
Class H NRN/NRS................................................ F24
Class H CRN/CRS................................................ F25

G
Special Purpose

CP 600V Cable Protectors......................................G2
2CL 250V Cable Protectors..................................G10
A60C Capacitor Fuses.......................................... G11
A4BX Welder Protectors.......................................G12
A2Y & A6Y Form 600 Fuses.................................G13
Telecommunication Fuses....................................G15
Forklift Truck Fuses...............................................G18
DC Rated Fuses...................................................G20
Photovoltaic Fuses................................................G38

H
Fuse Blocks & Holders

UltraSafe™ USCC & USM.....................................H2
UltraSafe™ USFM..................................................H4
UltraSafe™ US3J & US6J......................................H6
UltraSafe™ US14 & US22......................................H8
Open Style Class J & SJ Series...........................H12
Open Style Midget & Class CC............................H16
Open Style Class H, K & R...................................H18
Open Style Class T...............................................H25
Open Style Class G..............................................H30
Open Style Miniature............................................H32
In-Line Fuse Holders / FEB, FEC, FEX,
FEY Series - Midget/Class CC.............................H33
Panel Mount Fuse Holders /
GPM Series...........................................................H37
Semiconductor Fuse Blocks /
P243/P266/P292...................................................H44
Modular Semiconductor Fuse Blocks /
1SC/1MSC............................................................H45
Semiconductor Fuse Holders / 703,
U705, U710 Series................................................H46
Ferrule Fuse Holders / PS20x127........................H48
Fuse Bases / NH Dimension................................H50
Dead Front Fuse Covers /DFC Series.................H55
Fuse Block Accessories /
DFC3M, DFC3LP & DRM.....................................H57
Ferrule Fuse Clips / PC Board
Mount Fuse Clips..................................................H58
www.barr-thorp.com

1

Table of Contents
M

I
Power Distribution Blocks

P

Thermal Management

Application Information

Box Covers........................................................... J2
Fuse Reducers..................................................... J3
Fuse Pullers, Clip Clamps.................................... J4
Trigger® Indicator.................................................. J5
Shawmut Trigger®................................................. J5
Trigger® Actuator.................................................. J5
Blown Fuse Indicators.......................................... J6
Add-on Switches................................................... J6
IL Indicator............................................................ J6
PSC Microswitches............................................... J7
Protistor® Microswitches..................................... J10
Point of Sale Displays......................................... J12

Air Cooled
FabFin® Heatsink................................................. M2
Hollowfin® Heatsink............................................. M9
Mixed Metals Heatsink...................................... M10
Integrated Modules............................................ M11
Copper Heatsink................................................ M12
Dual Base Plate Heatsink.................................. M13
Extrusion Heatsink............................................. M14
Heatpipes.......................................................... M15
Embedded Heatpipes........................................ M16
Liquid Cooled
Aquasink® Heatsink........................................... M17
Aquamax® (Copper) Heatsink ........................... M19
Aquasurf® Heatsink............................................ M20
Aquamax® (Aluminum) Heatsink....................... M21
Cooling
Press-Pack Coolers........................................... M22
Cooling Systems................................................ M23
Product Materials & Tolerances......................... M24
R-Tools® 3D Heatsink Modeling......................... M26

K

N

Definitions . ............................................. P2
Fuse Descriptions.................................... P4
Fuse Construction & Operation............... P5
How to Read Time Current Curves......... P6
Low Voltage Motor Protection................. P7
Medium Voltage Motor Protection......... P13
Transformer Protection.......................... P14
		 General............................................ P14
		 Low Voltage Primary Protection....... P15
		 Secondary Fuses for LV
		 Transformers.................................... P16
		 Medium Voltage Primary Protection.... P17
		 Control Transformers....................... P23
Surge Trap® SPD, FAQ, Glossary......... P24
Semiconductor Protection..................... P29
DC Circuit Protection &
	 Fuse DC Ratings................................. P30
Temperature De-Rating......................... P31
Let-Thru Current & I2t............................ P33
Fuse Let-Thru Current Tables................ P35
Bus Duct Protection............................... P39
Capacitor Protection.............................. P40
Cable Protection.................................... P42
Welder Protection.................................. P43
Motor Starter General Info..................... P44
Fusible & Non-Fusible
	 Disconnect Switches........................... P45
Selectivity Between Fuses.................... P54
Short Circuit Calculations...................... P55
Properties of Materials.......................... P61
Stranded Copper and Aluminum
	 Cable Data.......................................... P62
Recommended Tightening Torque for
	 Bolt-on and Stud Mounted Fuses........ P62
Small Ampere Rating Equivalents......... P62
Short Circuit Rating............................... P63
11 Reasons for Using Current
	 Limiting Fuses..................................... P63
Fuse Obsolescence............................... P64
Class 1, Division 2 Locations................ P65
Suggested Specs for Mersen Fuses..... P66

Finger-Safe / FSPDB Series.................................. I2
Open Style 62000-69000....................................... I4
62000-63000 Mini Series....................................... I5
66000-67000 Intermediate Series......................... I6
68000-69000 Large Series.................................... I8

J
Circuit Protection Accessories

Disconnect Switches

UL508 Non-Fused Load Break Switches, FSLBS.K2
UL98 Non-Fused Load Break Switches, FSSC, SX,
SXDC, SC.............................................................K5
UL98 Fusible Disconnect Switches,
FB Series............................................................K18
Enclosed Disconnect Switches...........................K31
Fusible Shunt Trip Switches...............................K37

L
High Power Switches

Berg HA Range 1500V DC LV
Disconnect Switch................................................ L2
Berg HUVS Range 3.6kV MV
Changeover Disconnect Switch............................ L3
Berg HAS Range 12kV MV
Disconnect Switch................................................ L4
Berg HAS Range 24kV MV
Disconnect Switch................................................ L5
Berg HAS Range 36kV MV
Disconnect Switch................................................ L6
Fouilleret NORD 1500VDC
Disconnect Switch................................................ L7
Soule PBD 2000V DC Disconnect
Switch................................................................... L9
Hundt & Weber HSE-HSD Electrolytic
Cell Disconnect Switch....................................... L11
CBC Modular Bar Contactors............................. L12
CEX Field Excitation
Contactors..............................................................L13
Colomix 71.......................................................... L14
Systems Capability............................................. L15

2

Surge Protection

Surge-Trap® Modular SPD................................... N2
Surge-Trap® Pluggable SPD................................ N4
Surge-Trap® Type 1 T2 Series ............................ N6
Surge-Trap® Type 1 XR Series............................ N8
Surge-Trap® Type 1 XP Series ......................... N10
Surge-Trap® Type 1 XT Series ......................... N12
TPMOV® Technology......................................... N14
VSP MOV Fuses............................................... N16
Surge Switch..................................................... N18

O
Resources & Tools

Arc Flash Info Center........................................... O2
Electrical Services............................................... O3
Electrical Safety Seminars................................... O4
Fuse Control™ Program...................................... O5
High Power Test Lab........................................... O6
Protection Intelligence Quotient
(PIQ) Quizzes..................................................... O7
R-Tools® 3D Heatsink Modeling........................... O8
Select-A-Fuse® Software..................................... O9
Power Electronics Solutions.............................. O10
Solar Power Solutions........................................O11
Wind Power Solutions....................................... O12
Technical Services Support............................... O13

Index.............................................................Index 1

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Product Quick Selector
Application

Recommended Prodcut

Section

Low Voltage

A60C Type 121

G

Medium Voltage

A100C, A150C; A200C; A250C, A300C, A430C, A550C

E

Control Circuits

Class CC and Midget Fuses

A, C

Electronic Circuit Protection

Midget Miniature, Micro and PC Mount Fuses

C

General Circuits (Lighting, Resistance, Heating)

Class J - AJT, A4J

A, B

Class RK1 - A2D, A2K (250V): A6D, A6K (600V)

A, B

Class RK5 - TR (250V); TRS (600V)

B

Class K [50,000A I.R.] - OT (250V), OTS (600V)

B

Class H [10,000A I.R.] - NRN, CRN (250V) Canadian, NRS, CRS (600V) Canadian

F

Amp-Trap 2000 Fuses Sized for IEC Type 2 - Class J - AJT; Class L - A4BQ;
Class RK1 - A2D (250V), A6D (600V); Class CC - ATDR, ATQR

A

Capacitor

Loads Requiring “No-Damage” Protection
Mains, Feeders, Branch Circuits
Low Voltage - Above 600A
- 600A and less
Medium Voltage

Class L - A4BQ, A4BY, A4BT

A, B

Class J or Class RK1 - AJT, A4J, A2D/A6D, A2K/A6K

A, B

E” Rated - A055 (5kV), A155 (15kV), 9F60 & 9F62 Series

E

Motors
Low Voltage - Above 600A

Class L - A4BQ, A4BY, A4BT

A, B

Class J - AJT, Class RK1 - A2D (250V), A6D (600V) or Class RK5 - TR (250V), TRS (600V)

A, B

Medium Voltage

“R” Rated - A240R (2.4kV), A480R (4.8kV), A072 (7.2kV), 9F60

E

Small Motors

Class CC - ATDR

A

Amp-Trap® Form 101 Fuses, Protistor Fuse

D

Cable Protection

Cable Protectors - CP-C (for copper cable) and CP–A- (for aluminum cable)

G

Solar Power

Helio Protection Fuses (HP6M, HP10M, HP6J)

G

Fuses

A, B, C, E

Fuse Holders

H

DC Switches (SXDC)

K

Surge Protection Devices

N
N

- 600A and less

Semiconductor Protection

Surge Protection
DIN-Rail

ST, STP

UL Type 1

STT2, STX(-)

N

MOV

TPMOV

N

Switching
Low Voltage - UL508

FSLBS

K

Low Voltage - Non-Fuses/Fused

SX, FBJ, FBL

K

1500V to 36V (High Power)

HA, NORD, PBD

L

Contactors

CBC, CEX

L

TGL, TGN, TGS, GMS

G

Air Cooled

Fabfin, Hollowfin, Mixed Metals, Integrated, Copper, Dual Base Plate, Extrusion, Heatpipes, Embedded Pipes

M

Liquid Cooled

Aquasink, Aquamax (Copper & Aluminum), Aquasurf

M

Telecom
Thermal Management

Transformers
Low Voltage - Above 600A

Class L - A4BY, A4BT

B

Class J - AJT or Class RK5 - TR 250V), TRS (600V)

A, B

Medium Voltage

“E” Rated - A055 (5kV), A155 (15kV), 9F60 & 9F62 Series

E

Control Transformers

Class CC - ATQR

A

Welder Protectors - A4BX (Type 150) - Class K Dims., A4BX (Type 150J) - Class J Dims.

G

- 600A and less

Welders

The following are U.S. Trademarks of Mersen USA Newburyport-MA, LLC and apply to the products described herein:

R

Amp-Trap®
OEM CentralTM
Select-A-Fuse®
Surge-Trap® SPD UltraSafeTM
FabFin®
Hollowfin®
Aquasink®
Aquamax®
Aquasurf®
Aquamax®
R-Tools® 3D Heatsink Modeling
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123 www.barr-thorp.com

3

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Amp-Trap 2000® Fuses
A

For Type 2, No Damage circuit protection in all the configurations you need.

Your problem:
You need maximum overcurrent

A

Amp-Trap 2000 Fuses

protection
to prevent costly
damage to today’s
highly sensi-

• Class J / AJT..................................... A2
• Class L / A4BQ.................................. A4

tive motor and

• Class RK1 / A2D-R & A6D-R............. A6

electrical-system

• Class CC / ATDR............................... A8

components. That
way, plant shutdowns, replacement costs, and repair bills are kept

• Class CC / ATQR............................. A10

to an absolute minimum.
Our solution: By opening in less than 1/4 cycle under short
circuit conditions, Amp-Trap 2000 fuses current limit enough to
prevent undue downstream damage — and therefore comply
with the extra-stringent IEC, Type-2 standard. In addition to being
the industries most current-limiting fuses, the time-delay feature
allows for motor starting and transformer inrush current without
nuisance opening adding to the reliability and longevity of your
electrical system.
Want more information fast? For more technical or applicationspecific information, please call our Amp-Trap 2000 experts, at
978-462-6662; 416-252-9371 in Canada; or visit our website at
us-ferrazshawmut.mersen.com.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

AJT Time-delay/Class J
SmartSpot® with maximum circuit protection
Amp-Trap 2000® SmartSpot AJT fuses now provide a visual open fuse indicator.
With advanced material technology the AJT fuse provides IEC Type 2 No Damage
protection to main, feeder, and branch circuits, for all types of loads — yet, they
require only half the mounting space needed for 600VAC Class RK fuses. AJT’s
time-delay characteristics are ideal for handling typical motor and transformer inrush
currents, while also providing superior current-limiting ability.

Features/Benefits:
••
••
••
••
••
••
••
••
••
••
••

Solid state SmartSpot visual blown fuse indicator
Time-delay for motor starting and transformer inrush 	
300kA interrupting rating - self-certified, UL witnessed tests
Extremely current-limiting for low peak let-thru current
Most current-limiting UL class fuse
Recommended for Arc Flash energy reduction	
Small footprint requires less mounting space and allows smaller, more
economical fuse blocks
Easy 2-to-1 selectivity for prevention of nuisance shutdowns
Unique Class J dimensions prevent replacement errors
High-visibility orange label gives instant brand recognition
Metal-embossed date and catalog number for traceability and lasting
identification

•• Fiberglass body provides dimensional stability in harsh industrial settings
•• High-grade silica filler ensures fast arc quenching 	
•• Optional EI indicator/switch mount for AJT70 to 600 open fuse indication

Highlights:
••
••
••
••
••
••

Time-delay
Highly current-limiting
Arc Flash mitigating
DC ratings
Optional mechanical indicator (70

••
••
••
••
••
••
••
••
••
••

Motor circuits
Mains
Feeders
Branch circuits
Lighting, heating & general loads
Transformers
Control panels
Circuit breaker back-up
Bus duct
Load centers

Note: See motor fuse applications tables
on page P7

A2

Volts	 : 600VAC or less
	

: 500VDC or less

Amps	 : 1 to 600A
IR	

: 200kA I.R. AC

	

: 100kA I.R. DC

(Self-certified for 600VAC, 300kA
I.R., UL witnessed).

Applications:

SmartSpot indicator

to 600A fuses)

Ratings:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Approvals:
AJT (1-600):

•• UL listed to standard 248-8
File E2137

•• DC listed to UL standard 248
•• CSA certified to standard
C22.2 No. 248.8

•• IEC 269-2-1

AJT (70-600) EI:

•• UL listed
•• DC tested to UL standard 248

www.barr-thorp.com

AJT Time-delay/Class J
Catalog Numbers (amps)
AJT4-1/2

AJT25

AJT125

AJT5

AJT30

AJT150

AJT1-1/2

AJT5-6/10

AJT35

AJT175

AJT1-6/10

AJT6

AJT40

AJT200

AJT1-8/10

AJT6-1/4

AJT45

AJT225

AJT2

AJT7

AJT50

AJT2-1/4

AJT8

AJT60

AJT2-1/2

AJT9

AJT2-8/10

AJT70

AJT10

AJT3

AJT80

AJT12

AJT90

Catalog Number

Fuse

600V or Less

Ampere
Rating

1 Pole

3 Pole

AJT250

0-30

US3J1I

US3J3I

AJT300

31-60

US6J1I

US6J3I

AJT350

61-100

61036J

61038J

AJT400

101-200

62001J

62003J

AJT450

201-400

64031J

64033J

401-600

6631J

6633J

AJT3-2/10

AJT15

AJT100

AJT500

AJT3-1/2

AJT17-1/2

AJT110

AJT600

AJT4

AJT20

A

AJT1
AJT1-1/4

Recommended Fuse Blocks With Box
Connectors for Amp-Trap® Class J Fuses

A variety of pole configurations and termination provisions are available, see section H.

Note: SmartSpot visual indicator is not available (1-7A)

Dimensions
A

Ampere
Rating
1-30

B

C

D

E

F

G

H

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

2-1/4

57

13/16

21

-

-

-

-

-

-

-

-

-

-

-

-

31-60

2-3/8

60

1-1/16

27

-

-

-

-

-

-

-

-

-

-

-

-

61-100

4-5/8

117

1-1/16

27

1/8

3.2

3/4

19

1

25

3-5/8

92

3/8

10

9/32

7

101-200

5-3/4

146

1-5/8

41

3/16

4.8

1-1/8

29

1-3/8

35

4-3/8

111

3/8

10

9/32

7

201-400

7-1/8

181

2-1/8

54

1/4

6.3

1-5/8

41

1-7/8

48

5-1/4

133

17/32

14

13/32

10

401-600

8

203

2-1/2

64

3/8

9.5

2

51

2-1/8

54

6

152

11/16

18

17/32

13

1-60A

70-600A

Optional Indicator/Microswitch Mount (EI) Dimensions:
Note: Fuses with the EI option are
designed to work with the AOS-S or
AOS-Q add-on switch, which is ordered
separately. See page J6 for details.

Catalog Number
AJT (70-100)-EI
AJT (110-200)-EI
AJT (225-400)-EI
AJT (450-600)-EI

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A
2.8
(71.0)
3.22
(81.8)
3.24
(82.2)
3.61
(91.8)

A3

A4BQ Time-delay/Class L
Put the highest current-limitation...at your service
Amp-Trap 2000® A4BQ fuses are 20% more current-limiting than any other Class L
fuse on the market. When correctly coordinated, they bring a superior level of
protection to service entrance equipment. Downstream circuit components have
maximum protection against short circuit let-thru current. A4BQ’s built-in, 4-second
time-delay characteristic (at 500% of rated current) accommodates harmless inrush
currents without nuisance opening.

Features/Benefits:

•• Fastest operation under short circuit conditions: Let-thru currents are
typically 20% lower, with a corresponding let-thru energy (clearing I2t) up to
40% lower than the next fastest Class L fuse

•• Time-delay for high inrush loads such as motors and transformers, without
nuisance opening

•• 300kA interrupting rating - self-certified, UL witnessed tests
•• Most current-limiting for lowest peak let-thru current; even at fault currents
up to 300kA

•• Recommended for Arc Flash energy reduction
•• Pure silver links ensure lowest let-thru current and longer fuse life
•• Easy 2-to-1 selectivity for prevention of nuisance shutdowns and
“blackouts”

•• Rejection-style design prevents replacement errors 	
•• High-visibility orange label gives instant brand recognition
•• Reduced inventory because A4BQ can replace all older types of Class L

Ratings:
Volts	 : 600VAC
	

: 500VDC

Amps	 : AC - 100 to 6000A
	

: DC - 601 to 3000A

IR	

: 200kA I.R. AC

	

: 100kA I.R. DC

(Self-certified for 600VAC, 300kA
I.R., UL witnessed).

fuses now in-service

•• Metal-embossed date and catalog number for traceability and lasting
identification

•• Fiberglass body provides dimensional stability in harsh industrial settings
•• High-grade silica filler ensures fast arc quenching

Approvals:
A4BQ (100-6000)

Highlights:

•• Time-delay
•• Industry’s most current-limiting
••
••
••
••

class L fuse
Arc Flash mitigating
Pure silver elements
AC & DC rated

Applications:
••
••
••
••
••
••

Mains
Feeders
Large motors
Lighting, heating & general loads
Circuit breaker back-up
DC rated: UPS DC links,

Optional mechanical TA indicator

battery disconnects, other DC

(100-6000A)

applications

•• UL listed to standard 248-10
(601-6000A) File E2137

•• DC listed to UL standard 248
(601-3000A)

•• CSA certified to standard C22.2
No. 248.10 (601-6000A)

•• UL recognized (100-600A)
A4BQ (100-6000) - TA

•• UL listed (601-6000A)
•• UL recognized (100-600A)

Please contact factory for special
trigger actuator

A4

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A4BQ Time-delay/Class L
Catalog Numbers (amps)
A4BQ500

A4BQ1000

A4BQ2000

A4BQ150

A4BQ600

A4BQ1200

A4BQ2500

A4BQ200

A4BQ601

A4BQ1350

A4BQ2501

A4BQ250

A4BQ650

A4BQ1400

A4BQ300

A4BQ700

A4BQ350

Fuse

Catalog Number

Ampere

600V or Less

A4BQ3000

Rating

3 Pole

A4BQ1500

A4BQ3500

100-800

P48F

A4BQ750

A4BQ1600

A4BQ3800

A4BQ400

A4BQ800

A4BQ1800

A4BQ4000

801-1200

P412F

A4BQ450

A4BQ900

A4BQ1900

A4BQ5000

A

A4BQ100

Recommended Fuse Blocks
for Amp-Trap® Class L Fuses

Catalog number P48F is UL recognized
Catalog number P412F is self-certified

A4BQ6000
Note: For remote blown fuse trigger actuator option add “-TA”
to end of catalog number. Example: A4BQ1600-TA

Dimensions
A

Ampere

B

C

D

E

Rating

in

mm

in

mm

in

mm

in

mm

in

mm

100-600

8-5/8

219

2

51

5/16

8

1-5/8

41

2-13/32

61

601-800

8-5/8

219

2-1/2

63

3/8

9

2

51

2-13/32

61

801-1200

10-3/4

273

2-1/2

63

3/8

9

2

51

3-15/32

88

1201-1600

10-3/4

273

3

76

7/16

11

2-3/8

60

3-15/32

88

1601-2000

10-3/4

273

3-1/2

89

1/2

12

2-3/4

70

3-15/32

88

2001-2500

10-3/4

273

4-1/2

114

3/4

19

3-1/2

89

3-15/32

88

2501-3000

10-3/4

273

5

127

3/4

19

4

102

3-15/32

88

3001-4000

10-3/4

273

5-3/4

146

3/4

19

4-3/4

121

3-15/32

88

4001-5000

10-3/4

273

6-1/4

159

1

25

5-1/4

133

3-15/32

88

5001-6000

10-3/4

273

7-1/8

181

1

25

5-3/4

146

3-15/32

88

100-800A

2001-3000A

801-2000A

3001-4000A
4001-6000A

Safety Note: Class L fuses are dimensioned for one-way interchangeability. A Class L fuse of any lower ampere rating can be substituted
for a given Class L fuse.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A5

A2D-R & A6D-R Time-delay/Class RK1
Upgrade yesterday’s circuits to today’s Type 2 protection
The Amp-Trap 2000® SmartSpot® A2D-R and A6D-R fuses feature a visual open fuse
indicator and provide IEC Type 2 No Damage protection to main, feeder, and branch
circuits for all types of loads. With time-delay characteristics for handling harmless
in-rush currents, current-limiting ability and a wide range of ratings (from 1 to 600
Amperes), A2D-R and A6D-R fuses give excellent protection for all your applications.

Features/Benefits:

•• Solid state SmartSpot visual blown fuse indicator
•• Time-delay for motor starting and transformer inrush currents without
••
••
••
••
••

nuisance opening
600VAC & 600VDC dual rated
300kA interrupting rating - self-certified, UL witnessed tests
Extremely current-limiting for low peak let-thru current
Recommended for Arc Flash energy reduction
Easy 2-to-1 selectivity for prevention of nuisance shut downs and “black
outs”

•• Rejection-style design prevents replacement errors (when used with
recommended fuse blocks)

•• High-visibility orange label gives instant brand recognition
•• Reduced inventory by taking the place of class RK5, K, and H fuses
•• Metal-embossed date and catalog number for easier traceability and lasting
identification

•• Fiberglass body provides dimensional stability in harsh industrial settings

Ratings:
A2D-R
Volts	 : 250VAC/DC
Amps	 : 1/10 to 600A (AC)
	

: 15 to 600A (DC)

IR	

: 200kA I.R. AC

	

: 100kA I.R. DC

A6D-R
Volts	 : 600VAC/DC
Amps	 : 1/10 to 600A
IR	

: 200kA I.R. AC

	

: 100kA I.R. DC

(Self-certified for 300kA I.R., UL

Highlights:
••
••
••
••
••

SmartSpot indicator
Time-delay
Current-limiting
Arc Flash mitigating
Plated terminals

Applications:
••
••
••
••
••
••
••

witnessed.)

Motors
Safety switches
Transformers
Branch circuit protection
Disconnects
Control panels
All general-purpose circuits

Approvals:

•• UL listed to standard 248-12
File E2137

•• DC listed to UL standard 248
•• CSA certified to standard C22.2
No. 248.12

Note: See motor fuse applications tables
on page P7

A6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Catalog Numbers (amps)
250V

Recommended Fuse Blocks
With Box Connectors
for Amp-Trap® Class RK1 Fuses

600V

A2D1/10R

A2D3-1/2R

A2D50R

A6D1/10R

A6D3-1/2R

A6D50R

A2D15/100R

A2D4R

A2D60R

A6D15/100R

A6D4R

A6D60R

A2D2/10R

A2D4-1/2R

A2D70R

A6D2/10R

A6D4-1/2R

A6D70R

A2D3/10R

A2D5R

A2D75R

A6D3/10R

A6D5R

-

A2D4/10R

A2D5-6/10R

A2D80R

A6D4/10R

A6D5-6/10R

A6D80R

A2D1/2R

A2D6R

A2D90R

A6D1/2R

A6D6R

A6D90R

A2D6/10R

A2D6-1/4R

A2D100R

A6D6/10R

A6D6-1/4R

A6D100R

A2D8/10R

A2D7R

A2D110R

A6D8/10R

A6D7R

A6D110R

A2D1R

A2D8R

A2D125R

A6D1R

A6D8R

A6D125R

A2D1-1/8R

A2D9R

A2D150R

A6D1-1/8R

A6D9R

A6D150R

A2D1-1/4R

A2D10R

A2D175R

A6D1-1/4R

A6D10R

A6D175R

A2D1-4/10R

A2D12R

A2D200R

A6D1-4/10R

A6D12R

A6D200R

A2D1-6/10R

A2D15R

A2D225R

A6D1-6/10R

A6D15R

A6D225R

A2D1-8/10R

A2D17-1/2R

A2D250R

A6D1-8/10R

A6D17-1/2R

A6D250R

A2D2R

A2D20R

A2D300R

A6D2R

A6D20R

A6D300R

A2D2-1/4R

A2D25R

A2D350R

A6D2-1/4R

A6D25R

A6D350R

A2D2-1/2R

A2D30R

A2D400R

A6D2-1/2R

A6D30R

A6D400R

A2D2-8/10R

A2D35R

A2D450R

A6D2-8/10R

A6D35R

A6D450R

A2D3R

A2D40R

A2D500R

A6D3R

A6D40R

A6D500R

A2D3-2/10R

A2D45R

A2D600R

A6D3-2/10R

A6D45R

A6D600R

A

A2D-R & A6D-R Time-delay/Class RK1
Catalog Number

Fuse
Ampere
Rating

250V or Less

600V or Less

1 Pole

3 Pole

1 Pole

3 Pole

0-30

20306R

20308R

60306R

60308R

31-60

20606R

20608R

60606R

60608R

61-100

21036R

21038R

61036R

61038R

101-200

22001R

22003R

62001R

62003R

201-400

24001R

24003R

64001R

64003R

401-600

2631R

2633R

6631R

6633R

A variety of pole configurations and termination
provisions is available, see section H.

Note: SmartSpot visual indicator is not available (1/10-7A)

Dimensions
A

Ampere
Rating

In

B
mm

C

D

E

In

mm

In

mm

In

mm

In

mm

250V-A2D
0-30

2

51

9/16

14

-

-

-

-

-

-

31-60

3

76

13/16

21

-

-

-

-

-

-

61-100

5-7/8

149

1-1/16

27

1/8

3

3/4

19

1

25

101-200

7-1/8

181

1-9/16

40

3/16

5

1-1/8

28

1-3/8

35

201-400

8-5/8

219

2-1/16

53

1/4

6

1-5/8

41

1-7/8

48

401-600

10-3/8

264

2-9/16

66

1/4

6

2

51

2-1/4

57

0-30

5

127

13/16

21

-

-

-

-

-

-

31-60

5-1/2

139

1-1/16

27

-

-

-

-

-

-

61-100

7-7/8

200

1-5/16

34

1/8

3

3/4

19

1

25

101-200

9-5/8

244

1-13/16

46

3/16

5

1-1/8

28

1-3/8

35

201-400

11-5/8

295

2-9/16

66

1/4

6

1-5/8

41

1-7/8

48

401-600

13-3/8

340

3-1/8

80

1/4

6

2

51

2-1/4

57

600V-A6D

0-60A
61-600A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A7

ATDR Time-delay/Class CC
The best protection for today’s small motors
Amp-Trap 2000® ATDR small-dimension fuses can provide IEC Type 2 No Damage
protection to your facility’s increasingly sensitive branch circuit components and small
motors – minimizing the risk of fault-related damage. ATDR Class CC fuses deliver
the best time-delay characteristics in their class with excellent cycling ability for small
motor loads.

Features/Benefits:

•• Time-delay for motor starting inrush currents without nuisance opening
•• Highly current-limiting for low peak let-thru current
•• Improved cycling ability for frequent motor starts/stops without nuisance
fuse opening

•• Rejection-style design prevents replacement errors (when used with
recommended fuse blocks)

•• High-visibility orange label ensures instant brand recognition, simplifies
replacement

•• Metal-embossed date and catalog number for traceability and lasting
identification

•• Fiberglass body provides dimensional stability in harsh industrial settings
•• High-grade silica filler ensures fast arc quenching and optimum
current-limitation

Volts	 : 600VAC
	

: 300VDC

Amps	 : 1/4 to 30A
IR	

: 200kA I.R. AC

	

: 100kA I.R. DC

Applications:

Highlights:

•• Time-delay
•• Best choice for small motor
protection

Ratings:

•• Highly current-limiting
•• AC & DC rated

••
••
••
••

Small motors
Contactors
Lighting, heating & general loads
Branch circuit protection

Note: See motor fuse applications
tables on page P7

Approvals:

•• UL listed to standard 248-4
File E2137

•• CSA certified to standard
C22.2 No. 248.4

•• DC listed to UL standard 248

A8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

ATDR Time-delay/Class CC
ATDR1/4

ATDR1-1/2

ATDR3

ATDR6

ATDR1/2

ATDR1-6/10

ATDR3-2/10

ATDR6-1/4

ATDR15

ATDR8/10

ATDR1-8/10

ATDR3-1/2

ATDR7

ATDR17-1/2

ATDR1

ATDR2

ATDR4

ATDR7-1/2

ATDR20

ATDR1-1/8

ATDR2-1/4

ATDR4-1/2

ATDR8

ATDR25

ATDR1-1/4

ATDR2-1/2

ATDR5

ATDR9

ATDR30

ATDR1-4/10

ATDR2-8/10

ATDR5-6/10

ATDR10

A

Catalog Numbers (amps)
ATDR12

Recommended Fuse Blocks for Class CC Fuses
Catalog Numbers
Number
of
Poles

UltraSafe™
Indicating
Fuse Holder

ADDER

Screw
Connector
w/ Double
Quick Connects

Pressure Plate
Connector
w/ Double
Quick Connects

Copper
Box
Connector

30310R

30320R

30350R

1

USCC1I

30311R

30321R

30351R

2

USCC2I

30312R

30322R

30352R

3

USCC3I

30313R

30323R

30353R

3

USFMCCI

Dimensions

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A9

ATQR Time-delay/Class CC
Take control of fault currents headed for your control
transformer
ATQR small-dimension fuses feature time-delay characteristics ideally suited for the
high inrush currents of control transformers, solenoids, and similar inductive loads.
Mersen’s ATQR fuses provide superior protection for the branch circuits of electrical
distribution systems.

Features/Benefits:

•• Time-delay for control transformer inrush loads without nuisance opening
•• Highly current-limiting for low peak let-thru current
•• Rejection-style design prevents replacement errors (when used with
recommended fuse blocks)

•• High visibility orange label ensures instant brand recognition, and simplifies
replacement

•• Metal-embossed date and catalog number for traceability and lasting
identification

•• Fiberglass body provides dimensional stability in harsh industrial settings
•• High-grade silica filler ensures fast arc quenching and high current
limitation

Highlights:

Applications:

•• Time-delay
•• Best choice for small transformer
protection

•• Current-limiting

••
••
••
••

Ratings:
Volts	 : 600VAC
	

: 300VDC

Amps	 : 1/10 to 30A
IR	

: 200kA I.R. AC

	

: 100kA I.R. DC

Control transformers
Solenoids
Inductive loads
Lighting, heating & generalpurpose loads

Note: See motor fuse applications
tables on page P7

Approvals:

•• UL listed to standard 248-4
File E2137

•• DC listed to UL standard 248
•• CSA certified to standard
C22.2 No. 248.4

A10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

ATQR Time-delay/Class CC
ATQR1/10

ATQR8/10

ATQR2-8/10

ATQR7-1/2

ATQR1/8

ATQR1

ATQR3

ATQR8

ATQR3/16

ATQR1-1/8

ATQR3-2/10

ATQR9

ATQR2/10

ATQR1-1/4

ATQR3-1/2

ATQR10

ATQR1/4

ATQR1-4/10

ATQR4

ATQR12

ATQR3/10

ATQR1-1/2

ATQR4-1/2

ATQR15

ATQR4/10

ATQR1-6/10

ATQR5

ATQR17-1/2

ATQR1/2

ATQR1-8/10

ATQR5-6/10

ATQR20

ATQR6/10

ATQR2

ATQR6

ATQR25

ATQR2-1/4

ATQR6-1/4

ATQR30

ATQR2-1/2

ATQR7

ATQR3/4

A

Catalog Numbers (amps)

Recommended Fuse Blocks for Class CC Fuses
Catalog Numbers
Number
of
Poles

UltraSafe™
Indicating
Fuse Holder

ADDER

Screw
Connector
w/ Double
Quick Connects

Pressure Plate
Connector
w/ Double
Quick Connects

Copper
Box
Connector

30310R

30320R

30350R

1

USCC1I

30311R

30321R

30351R

2

USCC2I

30312R

30322R

30352R

3

USCC3I

30313R

30323R

30353R

3

USFMCCI

Dimensions

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A11

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

North American Power Fuses
The most popular North American power fuses to meet the most

B

popular protection priorities

Your problem:
Today, you need a
time-delay power
fuse that
can handle normal

B North American Power . 	
	 Fuses

surges. Tomorrow,

• Class RK5 / Tri-Onic® TR & TRS....... B2

it’s a power

• Class RK5 / Tri-Onic® TRS-RDC....... B4

fuse with a high
interrupting rating
and the added

• Class J / Amp-Trap® HSJ.................. B6
• Class J / Amp-Trap® A4J................... B8

security of rejection dimensions. The day after that, one of those

• Class L / Amp-Trap® A4BY.............. B10

economical one-time power fuses will do the trick. But where can

• Class L / Amp-Trap® A4BT.............. B12

you turn for all three?

• Class T / Amp-Trap® A3T & A6T...... B14

Our solution: Mersen’s comprehensive power fuse

• Class RK1 / Amp-Trap® A2K & A6K... B16

offering covers a complete range of applications and a complete

• Class G / Amp-Trap® AG................. B18

range of circuit-protection needs. Whether it’s the characteristics
of our Tri-Onic® Time-delay fuses. The high current-limiting
capacity of our original Amp-Trap® power fuses. The cost-efficient

• Class CC / Amp-Trap® ATMR.......... B19
• Class K-5 / One-time OT & OTS..... B20

protection of our One-Time fuses. Or some other application-

• Class H / Renewable RF & RFS..... B22

specific power fuse solution.

• Plug Fuses...................................... B24

Want more information fast? For more technical or applicationspecific information, please call our power fuse experts, at 978462-6662; 416-252-9371 in Canada; or visit our website at
us-ferrazshawmut.mersen.com.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

TR-R & TRS-R Time-delay/Class RK5
The industry’s most popular fuse for motor circuit protection
With advanced material technology added to the existing product, the Tri-Onic® TR
and TRS current-limiting time-delay fuses are engineered for overcurrent protection of
motors and transformers, service entrance equipment, feeder and branch circuits. TriOnic fuse’s proven time-delay characteristic safely handles harmless starting currents
and inrush currents associated with today’s motors and transformers. Now available
with optional SmartSpot® blown fuse indication technology.

Features/Benefits:

•• Optional solid state SmartSpot blown fuse indicator
•• Time-delay for motor start-ups and transformer inrush currents without
nuisance opening

•• Current-limiting for low peak let-thru current
•• Rejection-style design prevents replacement errors (when used with
recommended fuse blocks)

•• Easy-to-read label for quick brand recognition and replacement
•• Metal-embossed date and catalog number for traceability and lasting
identification

•• Fiberglass body provides dimensional stability in harsh industrial settings
•• High-grade silica filler ensures fast arc quenching and high current
limitation

Highlights:

•• Time-delay
•• Current-limiting
•• AC & DC rated

Applications:
••
••
••
••
••
••
••

Motor circuits
Mains
Feeders
Branch circuits

Ratings:

TR-R
Volts	
	
	
Amps	
IR	

: 250VAC
: 250VDC (.1-2.8A; 35-400A)
: 160VDC (3-30A; 450-600A)
: 1/10 to 600A
: 200kA I.R. AC / 20kA I.R. DC

TRS-R
Volts	
	
	
Amps	
IR	

: 600VAC
: 600VDC (.1-12A; 70-600A)
: 300VDC (15-60A)
: 1/10 to 600A
: 200kA I.R. AC / 20kA I.R. DC

Transformers
Service entrance equipment
General-purpose equipment

Approvals:

•• UL listed to standard 248-12 File
E2137

•• CSA certified to standard C22.2
no. 248.12

•• DC listed to UL standard 248
TRS only

B2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

TR-R & TRS-R Time-delay/Class RK5
Catalog Numbers (amps)
600V

TR1/10R*

TR3-1/2R*

TR50R

TRS1/10R*

TRS3-1/2R*

TRS50R

TR15/100R*

TR4R*

TR60R

TRS15/100R*

TRS4R*

TRS60R

TR2/10R*

TR4-1/2R*

TR70R

TRS2/10R*

TRS4-1/2R*

TRS70R

TR3/10R*

TR5R*

TR75R*

TRS3/10R*

TRS5R*

TRS75R*

TR4/10R*

TR5-6/10R*

TR80R

TRS4/10R*

TRS5-6/10R*

TRS80R

TR1/2R*

TR6R*

TRS90R

TRS1/2R*

TRS6R*

TRS90R

TR6/10R*

TR6-1/4R*

TR100R

TRS6/10R*

TRS6-1/4R*

TRS100R

TR8/10R*

TR7R*

TR110R

TRS8/10R*

TRS7R*

TRS110R

TR1R*

TR8R

TR125R

TRS1R*

TRS8R

TRS125R

TR1-1/8R*

TR9R

TR150R

TRS1-1/8R*

TRS9R

TRS150R

TR1-1/4R*

TR10R

TR175R

TRS1-1/4R*

TRS10R

TRS175R

TR1-4/10R*

TR12R

TR200R

TRS1-4/10R*

TRS12R

TRS200R

TR1-6/10R*

TR15R

TR225R

TRS1-6/10R*

TRS15R

TRS225R

TR1-8/10R*

TR17-1/2R

TR250R

TRS1-8/10R*

TRS17-1/2R

TRS250R

TR2R*

TR20R

TR300R

TRS2R*

TRS20R

TRS300R

TR2-1/4R*

TR25R

TR350R

TRS2-1/4R*

TRS25R

TRS350R

TR2-1/2R*

TR30R

TR400R

TRS2-1/2R*

TRS30R

TRS400R

TR2-8/10R*

TR35R

TR450R

TRS2-8/10R*

TRS35R

TRS450R

TR3R*

TR40R

TR500R

TRS3R*

TRS40R

TRS500R

TR3-2/10R*

TR45R

TR600R

TRS3-2/10R*

TRS45R

TRS600R

Catalog Number

Fuse
Ampere

250V

B

250V

Recommended Fuse Blocks With
Box Connectors For Tri-Onic®
Class RK5 Fuses
600V

Rating

1-Pole

3 -Pole

1-Pole

3-Pole

0-30

20306R

20308R

60306R

60308R

31-60

20606R

20608R

60606R

60608R

61-100

21036R

21038R

61036R

61038R

101-200

22001R

22003R

62001R

62003R

201-400

24001R

24003R

64001R

64003R

401-600

2631R

2633R

6631R

6633R

A variety of pole configurations and termination provisions
are available. Refer to Section H for details.

Note: Optional blown fuse visual indication available. To order, place “ID” at the end of the catalog number. Example: #TRS30RID
* Not available with optional blow fuse indicator.
Tin plated end caps are available on Non-ID fuses less than 60A. Example Part # TRP30R, TRSP30R

Dimensions
Ampere Rating

A

B

C

D

E

In.

mm

In.

mm

In.

mm

In.

mm

In.

mm

2

51

9/16

14

-

-

-

-

-

-

250V-TR Fuses
0-30
31-60

3

76

13/16

21

-

-

-

-

-

-

61-100

5-7/8

149

1-1/16

27

1/8

3

3/4

19

1

25

101-200

7-1/8

181

1-9/16

40

3/16

5

1-1/8

28

1-3/8

35

201-400

8-5/8

219

2-1/16

53

1/4

6

1-5/8

41

1-7/8

48

401-600

10-3/8

264

2-9/16

66

1/4

6

2

51

2-1/4

57

5

127

13/16

21

-

-

-

-

-

-

600V-TRS Fuses
0-30
31-60

5-1/2

139

1-1/16

27

-

-

-

-

-

-

61-100

7-7/8

200

1-5/16

34

1/8

3

3/4

19

1

25

101-200

9-5/8

244

1-13/16

46

3/16

5

1-1/8

28

1-3/8

35

201-400

11-5/8

295

2-9/16

66

1/4

6

1-5/8

41

1-7/8

48

401-600

13-3/8

340

3-1/8

80

1/4

6

2

51

2-1/4

57

0-60A

61-600A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

B3

TRS-RDC Time-delay/Class RK5
DC Rated for tough DC applications
The Tri-Onic® DC fuse series is designed for DC circuit protection in surface and
underground mines. The TRS-RDC is MSHA approved and meets the industry’s
most severe third party requirements for 600VDC rated fuses. The TRS-RDC is a
time-delay fuse with essentially the same time-current characteristic as the standard
Tri-Onic fuse.

Features/Benefits:

•• DC rated for mine duty and other long time-constant applications
•• Time-delay for motor start-ups and high inrush loads without nuisance
opening

•• Rugged glass melamine body for superior reliability in harsh environments

Highlights:
•• Time-delay
•• DC rated

Applications:
••
••
••
••

Mine circuits

Ratings:

Trailing cables

Volts	

: 300VDC (0.1 to 30A)

Pump motors

	

: 600VDC (35 to 400A)

Rail heaters

Amps	 : 1/10 to 400A
IR	

: 20kA I.R. DC

*consult factory for availability

Approvals:

•• MSHA approval no. 28-26-0

B4

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

TRS-RDC Time-delay/Class RK5
Recommended Fuse Blocks With
Box Connectors For Tri-Onic®
Class RK5 Fuses

TRS1/10RDC

TRS1-1/4RDC

TRS3-1/2RDC

TRS12RDC

TRS70RDC

TRS15/100RDC

TRS1-4/10RDC

TRS4RDC

TRS15RDC

TRS80RDC

TRS2/10RDC

TRS1-6/10RDC

TRS4-1/2RDC

TRS17-1/2RDC

TRS90RDC

TRS3/10RDC

TRS1-8/10RDC

TRS5RDC

TRS20RDC

TRS100RDC

TRS4/10RDC

TRS2RDC

TRS5-6/10RDC

TRS30RDC

TRS125RDC

TRS1/2RDC

TRS2-1/4RDC

TRS6RDC

TRS35RDC

TRS150RDC

TRS6/10RDC

TRS2-1/2RDC

TRS6-1/4RDC

TRS40RDC

TRS175RDC

TRS8/10RDC

TRS2-8/10RDC

TRS8RDC

TRS45RDC

TRS200RDC

TRS1RDC

TRS3RDC

TRS9RDC

TRS50RDC

TRS250RDC

TRS1-1/8RDC

TRS3-2/10RDC

TRS10RDC

TRS60RDC

TRS300RDC

Catalog Number

Fuse
Ampere

TRS400RDC

250V

B

Catalog Numbers (amps)

600V

Rating

1-Pole

3-Pole

1-Pole

3-Pole

0-30

20306R

20308R

60306R

60308R

31-60

20606R

20608R

60606R

60608R

61-100

21036R

21038R

61036R

61038R

101-200

22001R

22003R

62001R

62003R

201-400

24001R

24003R

64001R

64003R

A variety of pole configurations and termination provisions
are available. Refer to Section H for details.

Dimensions
A

Ampere

B

C

D

E

Rating

In.

mm

In.

mm

In.

mm

In.

mm

In.

mm

0-30

5

127

13/16

21

-

-

-

-

-

-

31-60

5-1/2

139

1-1/16

27

-

-

-

-

-

-

61-100

7-7/8

200

1-5/16

34

1/8

3

3/4

19

1

25

101-200

9-5/8

244

1-13/16

46

3/16

5

1-1/8

28

1-3/8

35

201-400

11-5/8

295

2-9/16

66

1/4

6

1-5/8

41

1-7/8

48

0-60 Amperes
61-400 Amperes

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

B5

HSJ High Speed/Class J
Protect your wiring and power semiconductors with a single
fuse
The High Speed J (HSJ) fuse combines the low I2t of a semiconductor fuse and the
branch circuit performance of a Class J UL listed fuse. This fuse was designed for the
starting characteristics of solid state motor controllers. The HSJ can provide branch
circuit protection per NEC requirements, as well as very low I2t for protection of
power semiconductors such as Diodes, SCR’s, GTO’s and SSR’s.

Features/Benefits:

•• Optimized over-load capability for withstanding elevated levels of current
during electronic motor controller starts

•• Low I2t (low thermal energy)
•• Excellent cycling ability for frequent starts/stops without nuisance opening

Highlights:
••
••
••
••

Current-limiting
AC & DC ratings
Low I2t
Compact size

Applications:
••
••
••
••
••
••
••

Branch circuits
Control panels
Electronic motor controllers
Phase controllers
Drives
Soft-starters
Solid state relays

Ratings:
Volts	

: 600VAC

	

: 500VDC

Amps	 : 1 to 600A (AC)
	

: 15 to 600A (DC)

IR	

: 200kA I.R. AC

	

: 100kA I.R. DC

	

: L/R =10mS or less

(Self Certified for 600VAC, 300kA
I.R., UL witnessed.)

Approvals:

•• UL listed to standard 248-8 File
E2137

•• CSA certified to standard C22.2
no. 248.8

•• DC listed to UL 248

B6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

HSJ High Speed/Class J
Recommended Fuse Blocks With Box
Connectors for Amp-Trap® Class J Fuses

HSJ1

HSJ90

HSJ3

HSJ100

Fuse

HSJ6

HSJ110

Ampere

HSJ10

HSJ125

Rating

1-Pole

3-Pole

HSJ15

HSJ150

0-30

US3J1I

US3J3I

HSJ17-1/2

HSJ175

31-60

US6J1I

US6J3I

HSJ20

HSJ200

61-100

61036J

61038J

HSJ25

HSJ225

101-200

62001J

62003J

HSJ30

HSJ250

201-400

64031J

64033J

HSJ35

HSJ300

401-600

6631J

6633J

HSJ40

HSJ350

HSJ45

HSJ400

HSJ50

HSJ450

HSJ60

HSJ500

HSJ70

HSJ600

Catalog Number
600V or Less

B

Catalog Numbers (amps)

A variety of pole configurations and
termination provisions are available. Refer to
Section H for details.

HSJ80

Dimensions
A

Ampere

B

C

D

E

F

G

H

Rating

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

1-30

2-1/4

57

13/16

21

-

-

-

-

-

-

-

-

-

-

-

-

31-60

2-3/8

60

1-1/16

27

-

-

-

-

-

-

-

-

-

-

-

-

61-100

4-4/8

117

1-1/8

29

1/8

3.2

3/4

19

1

25

3-5/8

92

3/8

10

9/32

7

101-200

5-3/4

146

1-5/8

41

3/16

4.8

1-1/8

29

1-3/8

35

4-3/8

111

3/8

10

9/32

7

201-400

7-1/8

181

2-1/8

54

1/4

6.3

1-5/8

41

1-7/8

48

5-1/4

133

17/32

13

13/32

10

401-600

8

203

2-1/2

64

3/8

9.5

2

51

2-1/8

54

6

152

11/16

18

17/32

13

1-60A

61-600A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

B7

A4J Fast Acting/Class J
For excellent current-limiting protection
A4J Class J fuses deliver excellent current-limiting protection to a wide variety of
applications. Their unique dimensions prevent the substitution of other fuses with
lower voltage ratings, interrupting ratings, or current-limiting capability.

Features/Benefits:

•• High current limitation for low peak let-thru current
•• Unique dimensions prevent replacement by other fuse classes
•• Fiberglass body provides dimensional stability in harsh industrial
environments

•• Easy-to-read imprint label for quick recognition and replacement

Highlights:

•• Fast-acting
•• Very current-limiting
•• DC ratings

Applications:
••
••
••
••
••
••
••
••

Capacitors
Load centers
Panelboards
Switchboards
Bus duct
Feeder circuits
Circuit breakers
Lighting, heating, and general

Ratings:
Volts	

: 600VAC

	

: 300VDC

Amps	 : 1 to 600A
IR	

: 200kA I.R. AC

	

: 100kA I.R. DC

loads

Approvals:

•• UL listed to standard 248-8 File
E2137

•• CSA certified to standard C22.2
no. 248.8

•• DC listed to UL 248
•• IEC 269-2-1

B8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A4J Fast Acting/Class J
Recommended Fuse Blocks
With Box Connectors for
Amp-Trap® Class J Fuses

A4J1

A4J50

A4J200

A4J3

A4J60

A4J225

A4J6

A4J70

A4J250

A4J10

A4J75

A4J300

A4J15

A4J80

A4J350

A4J20

A4J90

A4J400

A4J25

A4J100

A4J450

A4J30

A4J110

A4J500

A4J35

A4J125

A4J600

A4J40

A4J150

A4J45

A4J175

Catalog Number

Fuse
Ampere

B

Catalog Numbers (amps)

600V or Less

Rating

1-Pole

3-Pole

0-30

US3J1I

US3J3I

31-60

US6J1I

US6J3I

61-100

61036J

61038J

101-200

62001J

62003J

201-400

64031J

64033J

401-600

6631J

A variety of pole configurations and
termination provisions are available. Refer to
Section H for details.

Dimensions
A

Ampere

B

C

D

E

F

G

H

Rating

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

1-30

2-1/4

57

13/16

21

-

-

-

-

-

-

-

-

-

-

-

-

31-60

2-3/8

60

1-1/16

27

-

-

-

-

-

-

-

-

-

-

-

-

61-100

4-4/8

117

1-1/8

29

1/8

3.2

3/4

19

1

25

3-5/8

92

3/8

10

9/32

7

101-200

5-3/4

146

1-5/8

41

3/16

4.8

1-1/8

29

1-3/8

35

4-3/8

111

3/8

10

9/32

7

201-400

7-1/8

181

2-1/8

54

1/4

6.3

1-5/8

41

1-7/8

48

5-1/4

133

17/32

13

13/32

10

401-600

8

203

2-1/2

64

3/8

9.5

2

51

2-1/8

54

6

152

11/16

18

17/32

13

1-60A

61-600A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

B9

A4BY Class L
Count on the high interrupting rating of our most widely
used class L fuse
When it comes to protecting service entrance equipment, feeder circuits, and
circuit breakers, A4BY fuses are the industry’s favorite. The A4BY is a 100% rated
device and may be applied at continuous currents up to its ampere rating. A 4-second
minimum time-delay at 500% rating allows the A4BY to pass normal current surges
and to coordinate with ground fault relays.

Features/Benefits:

•• Unique dimensions prevent replacement by other fuse classes	
•• Blade stamped catalog numbers for permanent identification
•• Glass melamine body and plated terminals provide superior reliability in
harsh environments

Highlights:
••
••
••
••

Applications:

Current-limiting
4-second time-delay
DC ratings
Uniform characteristics in all
ampere ratings

••
••
••
••
••
••

Ratings:

Mains, feeders

Volts	

: 600VAC

Circuit breakers

	

: 300VDC

Load centers

Amps	 : 200 to 6,000A (AC)

Panelboards

	

: 200 to 2,500A (DC)

Switchboards

IR	

: 200kA.I.R. AC

Metering centers

	

: 100kA I.R. DC

Approvals:

•• UL listed to standard 248-10
(601-6000A) File E2137

•• CSA certified to standard C22.2
No. 248.10 (601-6000A)

•• Self-certified for DC per UL248
(601-6000A)

B10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A4BY Class L
A4BY200

A4BY801

A4BY2000

A4BY250

A4BY900

A4BY2001

A4BY300

A4BY1000

A4BY2200

Fuse

Catalog Number

Ampere

600V or Less
3-Pole

A4BY350

A4BY1100

A4BY2500

Rating

A4BY400

A4BY1200

A4BY3000

100-800

P48F

A4BY450

A4BY1201

A4BY3001

801-1200

P412F

A4BY500

A4BY1350

A4BY3500

A4BY600

A4BY1400

A4BY4000

A4BY601

A4BY1500

A4BY4001

A4BY650

A4BY1600

A4BY4500

A4BY700

A4BY1601

A4BY5000

A4BY750

A4BY1800

A4BY6000

B

Recommended Fuse Blocks
for Amp-Trap® Class L Fuses

Catalog Numbers (amps)

Catalog number P48F is UL recognized
Catalog number P412F is self-certified
A variety of pole configurations and
termination provisions are available. Refer
to Section H for details.

A4BY800
Note: For optional blown fuse trigger indicator add “-TI” to the end of part number.
Example: A4BY1600-TI. Consult factory for availability.

Dimensions
A

Ampere

B

C

D

E

Rating

in

mm

in

mm

in

mm

in

mm

in

mm

200-600

8-5/8

219

2

51

5/16

8

1-5/8

41

2-13/32

61

801-1200

10-3/4

273

2-1/2

63

3/8

9

2

51

3-15/32

88

1201-1600

10-3/4

273

3

76

7/16

11

2-3/8

60

3-15/32

88

1601-2000

10-3/4

273

3-1/2

89

1/2

13

2-3/4

70

3-15/32

88

2001-2500

10-3/4

273

4-1/2

114

3/4

19

3-1/2

89

3-15/32

88

2501-3000

10-3/4

273

5

127

3/4

19

4

102

3-15/32

88

3001-4000

10-3/4

273

5-3/4

146

3/4

19

4-3/4

121

3-15/32

88

4001-5000

10-3/4

273

6-1/4

159

1

25

5-1/4

133

3-15/32

88

801-2000A

200-800A

3001-4000A

2001-3000A

4001-6000A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

B11

A4BT Time-delay/Class L
When your heavier loads need protection A4BT fuses won’t
let you down
The high interrupting rating of A4BT current-limiting fuses is ideally suited for
protecting mains, feeders, and general circuits. The 10-second time-delay at 500%
of fuse rating is ideal for large motors and other loads with a high inrush. A4BT fuses
are suitable for DC applications up to 500VDC. An A4BT fuse can be applied to
normal loads up to its full ampere rating to allow 100% rating of equipment, while also
providing superior current-limiting ability.

Features/Benefits:

•• Unique dimensions prevent replacement by other fuse classes.
•• Blade-stamped catalog numbers for permanent identification
•• Glass melamine body and plated terminals provide superior reliability in
harsh environments

Highlights:
••
••
••
••

Applications:

Current-limiting
Full 10-second delay
DC ratings
Uniform characteristics in all
ampere ratings

••
••
••
••
••

Motors
Motor controllers
Transformers
Mains

Ratings:
Volts	

: 600VAC

	

: 500VDC

Amps	 : 200 to 2,000A
IR	

: 200kA I.R. AC

	

: 100kA I.R. DC

Feeders

Approvals:

•• UL Listed to standard 248-10
(601-2000A) File E2137

•• CSA Certified to standard C22.2
No. 248.10 (601-2000A)

•• Self-certified for DC per UL248
(601-2000)

B12

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A4BT Time-delay/Class L
Recommended Fuse Blocks
for Amp-Trap® Class L Fuses

Catalog Numbers (amps)
A4BT601

A4BT1100

A4BT250

A4BT650

A4BT1200

Fuse

Catalog Number

A4BT300

A4BT700

A4BT1400

Ampere

600V or Less
3-Pole

A4BT350

A4BT750

A4BT1500

Rating

A4BT400

A4BT800

A4BT1600

100-800

P48F

A4BT450

A4BT900

A4BT1800

801-1200

P412F

A4BT500

A4BT1000

A4BT2000

B

A4BT200

Catalog number P48F is UL recognized
Catalog number P412F is self-certified

A4BT600

A variety of pole configurations and termination
provisions are available. Refer to Section H for details.

Dimensions
A

Ampere

B

C

D

E

Rating

in

mm

in

mm

in

mm

in

mm

in

mm

200-600

8-5/8

219

2

51

5/16

8

1-5/8

41

2-13/32

61

601-800

8-5/8

219

2-1/2

63

3/8

9

2

51

2-13/32

61

801-1200

10-3/4

273

2-1/2

63

3/8

9

2

51

3-15/32

88

1201-1600

10-3/4

273

3

76

7/16

11

2-3/8

60

3-15/32

88

1601-2000

10-3/4

273

3-1/2

89

1/2

13

2-3/4

70

3-15/32

88

Safety Note: Class L fuses are dimensioned for one-way interchangeability.
A Class L fuse of any lower ampere rating can be substituted for a given Class L fuse.

200-800A

801-2000A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

B13

A3T & A6T Fast Acting/Class T
These small dimension fuses are the right fit... for a tight fit
Fast-acting A3T and A6T Class T fuses combine two highly desirable features - high
current limitation and a small physical size. Their unique dimensions prevent the
substitution of other fuses with lower voltage ratings or current-limiting capability.
These fuses have glass melamine bodies for superior dimensional stability and
catalog numbers stamped into the blades for permanent identification.

Features/Benefits:
••
••
••
••

Extremely current-limiting for low peak let-thru current
Unique dimensions prevent replacement by other fuse classes
Blade-stamped catalog numbers for permanent identification
Small physical size for greater design flexibility

Highlights:

Applications:

Fast-acting

Loadcenters

••
••
••
••

Extremely current-limiting
Small physical size
DC ratings

••
••
••
••
••

Panelboards
Switchboards
Circuit breakers
Metering centers

Ratings:
A3T
Volts	

: 300VAC / 160VDC

Amps	 : 1 to 1200A
IR	

: 200kA I.R. AC

	

: 50kA I.R. DC

A6T
Volts	

	
: 600VAC / 300VDC

Amps:	 : 1 to 800A
IR	

: 200kA I.R. AC

	

: 100kA I.R. DC

Approvals:

•• UL listed to standard 248-15 File
E2137

•• CSA certified to standard C22.2
no. 248.15

•• DC listed to UL standard 248

B14

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A3T & A6T Fast Acting/Class T
Catalog Numbers (amps)
600V

A3T1

A3T60

A3T300

A6T1

A6T60

A6T300

A3T3

A3T70

A3T350

A6T3

A6T70

A6T350

Ampere

A3T6

A3T80

A3T400

A6T6

A6T80

A6T400

Rating

A3T10

A3T90

A3T450

A6T10

A6T90

A6T450

A3T15

A3T100

A3T500

A6T15

A6T100

A6T500

A3T20

A3T110

A3T600

A6T20

A6T110

A6T600

A3T25

A3T125

A3T700

A6T25

A6T125

A6T700

A3T30

A3T150

A3T800

A6T30

A6T150

A6T800

A3T35

A3T175

A3T1000

A6T35

A6T175

A3T40

A3T200

A3T1200

A6T40

A6T200

A3T45

A3T225

A6T45

A6T225

A3T50

A3T250

A6T50

A6T250

Catalog Number
300V

600V

B

300V

Recommended Fuse Blocks With Box
Connectors for Amp-Trap® Class T Fuses

1-Pole

3-Pole

1-Pole

3-Pole

1-30

30306T

30308T

60306T

60308T

31-60

30606T

30608T

60606T

60608T

61-100

31001T

31003T

61031T

61033T

101-200

32031T

32033T

62031T

62033T

201-400

34031T

34033T

64031T

–

401-600

36031T

–

66031T

–

A variety of pole configurations and termination provisions are available.
Refer to Section H for details.

Dimensions
A

Ampere
Rating

B

C

D

E

F

G

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

1-30

.88

22.4

.41

10.3

-

-

-

-

-

-

-

-

-

-

61-100

2.16

54.9

.81

20.6

.12

3.2

.75

19.0

1.56

39.6

.28

7.1

.82

20.8

101-200

2.44

62.0

1.06

26.9

.19

4.8

.88

22.4

1.70

43.2

.34

8.6

.83

21.1

601-800

3.38

85.8

2.08

52.8

.38

9.7

1.75

44.4

2.22

56.4

.55

14.0

.88

22.4

801-1200

4.00

102

2.52

64.0

.44

11.2

2.00

50.8

2.53

64.3

.61

15.5

1.03

26.2

1-30

1.50

38.1

.57

14.5

-

-

-

-

-

-

-

-

-

-

31-60

1.57

39.9

.81

20.6

1.51

38.4

1.00

25.4

-

-

-

-

-

-

61-100

2.95

75.0

.82

20.8

.12

3.2

.75

19.0

2.35

59.7

.28

7.1

1.58

40.1

101-200

3.26

82.8

1.07

27.2

.19

4.8

.88

22.4

2.51

63.7

.34

8.6

1.61

41.0

201-400

3.62

92.1

1.62

41.3

.25

6.4

1.00

25.4

2.72

69.1

.41

10.4

1.70

43.2

401-600

3.98

101.2

2.06

52.4

.31

7.9

1.25

31.8

2.95

75.0

.48

12.2

1.70

43.2

601-800

4.33

110.0

2.50

63.5

.37

9.5

1.75

44.4

3.17

80.5

.56

14.1

1.70

43.2

300V-A3T Fuses

600V-A6T Fuses

A3T 1-60

A6T 1-30

G

A6T 31-60

G

A3T 61-1200

A6T 61-800

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

B15

A2K-R & A6K-R Fast Acting/Class RK1
These fast-acting fuses deliver a high degree of current
limitation where you need it most
Current-limiting A2K and A6K fuses provide excellent protection where high available
short circuit currents exist. These fast-acting fuses are particularly good for branch/
feeder circuits and back-up protection.

Features/Benefits:

•• Rejection style design prevents replacement by other fuse classes
•• Fiberglass body provides dimensional stability in harsh industrial
environments	

•• Easy-to-read imprint label for quick recognition and replacement
•• High degree of current limitation for low peak let-thru current

Highlights

•• Highly current-limiting
•• Fast-acting
•• Rejection style

Applications:
••
••
••
••
••
••
••

Loadcenters

Ratings:

Panelboards

A2K

Switchboards

Volts	

Bus duct

Amps	 : 1 to 600A

Feeder circuits

IR	

: 200kA I.R. AC

Non-inductive loads

	

: 20kA I.R. DC

Lighting circuits

A6K
Volts	

: 250VAC / DC

	
: 600VAC / 300VDC

Amps:	 : 1 to 600A
IR	

: 200kA I.R. AC

	

: 20kA I.R. DC

Approvals:

•• UL listed to standard 248-12 File
E2137

•• CSA certified to standard
C22.2 No. 248.12

•• Self-certified for DC per UL248

B16

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A2K-R & A6K-R Fast Acting/Class RK1
Catalog Numbers (amps)
600V

A2K1R

A2K35R

A2K175R

A6K1R

A6K35R

A6K175R

A2K3R

A2K40R

A2K200R

A6K3R

A6K40R

A6K200R

-

A2K45R

A2K225R

A6K4R

A6K45R

A6K225R

A2K5R

A2K50R

A2K250R

A6K5R

A6K50R

A6K250R

A2K6R

A2K60R

A2K300R

A6K6R

A6K60R

A6K300R

-

A2K70R

A2K350R

A6K8R

A6K70R

A6K350R

A2K10R

A2K80R

A2K400R

A6K10R

A6K80R

A6K400R

A2K15R

A2K100R

A2K500R

A6K15R

A6K100R

A6K500R

A2K20R

A2K110R

A2K600R

A6K20R

A6K110R

A6K600R

A2K25R

A2K125R

A6K25R

A6K125R

A2K30R

A2K150R

A6K30R

A6K150R

Catalog Number

Fuse
Ampere

250V

B

250V

Recommended Fuse Blocks With
Box Connectors For Amp-Trap®
Class RK1 Fuses
600V

Rating

1-Pole

3-Pole

1-Pole

3-Pole

0-30

20306R

20308R

60306R

60308R

31-60

20606R

20608R

60606R

60608R

61-100

21036R

21038R

61036R

61038R

101-200

22001R

22003R

62001R

62003R

201-400

24001R

24003R

64001R

64003R

401-600

2631R

2633R

6631R

6633R

A variety of pole configurations and termination
provisions are available. Refer to Section H for details.

Dimensions
Ampere Rating

A

B

C

D

E

in

mm

in

mm

in

mm

in

mm

in

mm

0-30

2

51

9/16

14

-

-

-

-

-

-

31-60

3

76

13/16

21

-

-

-

-

-

-

61-100

5-7/8

149

1-1/16

27

1/8

3

3/4

19

1

25

101-200

7-1/8

181

1-9/16

40

3/16

5

1-1/8

28

1-3/8

35

201-400

8-5/8

219

2-1/16

53

1/4

6

1-5/8

41

1-7/8

48

401-600

10-3/8

264

2-9/16

66

1/4

6

2

51

2-1/4

57

0-30

5

127

13/16

21

-

-

-

-

-

-

31-60

5-1/2

139

1-1/16

27

-

-

-

-

-

-

61-100

7-7/8

200

1-5/16

34

1/8

3

3/4

19

1

25

101-200

9-5/8

244

1-13/16

46

3/16

5

1-1/8

28

1-3/8

35

201-400

11-5/8

295

2-9/16

66

1/4

6

1-5/8

41

1-7/8

48

401-600

13-3/8

340

3-1/8

80

1/4

6

2

51

2-1/4

57

250V-A2K Fuses

600V-A6K Fuses

0-60A
61-600A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

B17

AG Class G
Amp-Trap® AG fuses fit right in to a wide variety of industrial
applications
The Mersen Amp-Trap AG fuse series is a complete line of Class G fuses. AG fuses
safely fit a wide variety of applications. Class G fuses are made in four physical
sizes and provide superior branch-circuit protection for lighting, heating, and
appliance circuits.

Features/Benefits:

•• Four unique sizes from ½-60 amperes do not allow inter-changeability with
other fuse classes

•• Fiberglass bodies provide dimensional stability in harsh industrial settings

Highlights:

Applications:

•• Current-limiting
•• Time-delay (above 5A)

•• Lighting
•• Heating*
•• Appliances

Ratings:

*except in Canada where fuses must be “P” or “D” type.

Amps	 : 1/2 to 60A

AG15

AG1

AG20

AG1-1/2

AG25

AG2

AG30

AG3

AG35

AG4

AG40

AG5

AG45

AG6

AG50

AG8

AG60

: 600VAC (1/2 to 20A)

	

: 480VAC (25 to 60A)

IR	

Catalog Numbers (amps)
AG1/2

Volts	

: 100kA I.R. AC

Approvals:

•• UL listed to standard 248-5 File

AG10

E2137

Dimensions

•• CSA certified to standard C22.2
A

Ampere

B

No. 248.5

C

Rating

in

mm

in

mm

in

mm

1/2-15A

1.31

33.3

.406

10.3

.28

7.1

20A

1.41

35.8

.406

10.3

.28

7.1

25, 30A

1.62

41.2

.406

10.3

.28

7.1

35-60A

2.25

57.2

.406

10.3

.50

Cross Reference: AG will replace the following fuses: Bussmann SC, Littelfuse SLC

B18

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

ATMR Fast Acting/Class CC
Small fuse - big protection for general circuits
Amp-Trap® ATMR fuses, in the Class CC family, are the smallest dimension 600VAC/
DC fuses suitable for branch circuit protection. The ATMR is a popular choice for

B

economical protection of control circuits and control circuit transformers where
available short circuit currents exceed 10,000 amperes. ATMR’s rejection dimensions
prevent substitution by lesser rated fuses. These fast acting fuses give currentlimiting protection to general circuits.

Features/Benefits:

•• Rejection-style design prevents replacement errors when used with
recommended fuse blocks

•• Versatile design for individual component and branch circuit protection

Applications:

Highlights:

••
••
••
••

•• Fast-acting
•• Very current-limiting

Control circuits

Ratings:

Lighting

Volts	

General loads
Branch circuit protection

Catalog Numbers (amps)
ATMR1/10

ATMR3-1/2

ATMR1/8

ATMR4

ATMR2/10

ATMR5

ATMR1/4

ATMR6

ATMR3/10

ATMR7

ATMR1/2

ATMR8

ATMR3/4

ATMR9

ATMR1

ATMR10

ATMR1-1/4

ATMR12

ATMR1-1/2

ATMR15

ATMR2

ATMR20

ATMR2-1/2

ATMR25

ATMR3

ATMR30

of Poles

Indicating
Fuse Holders

Adder

IR	

: 200kA 1.R. AC

	

: 100kA 1.R. DC

Approvals:

•• UL Listed to Standard 248-4 File
E2137

•• CSA Certified to Standard
C22.2 No. 248.4

•• DC listed to UL Standard 248

Recommended Fuse Blocks For Amp-Trap®
Class CC Fuses
UltraSafe™

Amps	 : 1/10 to 30A

Dimensions

	

Number

: 600VAC / DC

Screw

Pressure Plate

Connector with

Connector with

Cooper Box

Double Quick

Double Quick

Connector

Connects

Connects

30310R

30320R

30350R

1

USCC1I

30311R

30321R

30351R

2

USCC2I

30312R

30322R

30352R

3

USCC3I

30313R

30323R

30353R

3

USFMCCI

A variety of pole configurations and termination provisions are available. Refer to Section H for
details.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

B19

OT/OTN/OTS Class K-5
For versatility and economy, these general purpose fuses are
hard to beat
OT, OTN and OTS general purpose fuses provide low cost protection for feeder and
branch circuits serving lighting, heating, and other non-motor loads. OT, OTN and
OTS fuses will safely interrupt available short circuit currents up to 50,000 amperes
in all ratings. OT, OTN and OTS fuses are not rejection fuses – care should be taken
to ensure that replacement fuses do not have lower interrupting ratings than original
fuses. OTN 15 through 60 satisfy the Canadian electrical code requirement for Type
“P,” low melting-point, non-time-delay fuses.

Features/Benefits:

•• Easy to read imprint label for quick recognition and replacement
•• Low cost for high protection value

Highlights:

•• Versatile
•• Lowest cost protection for circuits
serving non-inductive loads

Applications:
••
••
••
••

Feeders
Branch circuits
Resistive heating
Residential and small commercial
installations

Ratings:

OT
Volts	 : 250VAC / DC
Amps	 : 1 to 600A
IR	
: 50kA I.R. AC
	
: 20kA I.R. DC
OTN (Canada)*
	
Volts	 : 250VAC
Amps:	 : 15 to 60A
IR	
: 50kA I.R. AC
OT
Volts	 : 600VAC / 300VDC
Amps	 : 1 to 600A
IR	
: 50kA I.R. AC
	
: 20kA I.R. DC

Approvals:

•• UL Listed to Standard 248-9 File
E2137

•• CSA Certified to Standard C22.2
No. 248.9*

•• Self-certified for DC per UL248
*The Canadian Electrical Code
requires these fuses in ratings
15 through 60A to be of the low
melting point design ­use OTN
15-60.

B20

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

OT/OTN/OTS Class K-5
Recommended Fuse Blocks With
Box Connectors For One-Time
Class K-5 Fuses

Catalog Numbers (amps)
250V

600V

OT1

OT30, OTN30*

OT125

OTS1

OTS30

OTS125

OT2

OT35, OTN35*

OT150

OTS2

OTS35

OTS150

OT3

OT40, OTN40*

OT175

OTS3

OTS40

OTS175

OT4

OT45, OTN45*

OT200

OTS4

OTS45

OTS200

Rating

1-Pole

3-Pole

1-Pole

3-Pole

OT5

OT50, OTN50*

OT225

OTS5

OTS50

OTS225

0-30

20306

20308

60306

60308

OT6

OT60, OTN60*

OT250

OTS6

OTS60

OTS250

31-60

20606

20608

60606

60608

OT7

OT65

OT300

–

–

OTS300

61-100

21036

21038

61036

61038

OT8

OT70

OT350

OTS8

OTS70

OTS350

101-200

22001

22003

62001

62003

OT10

OT75

OT400

OTS10

OTS75

OTS400

201-400

24001

24003

64001

64003

OT12

OT80

OT450

OTS12

OTS80

OTS450

401-600

2631

2633

6631

6633

OT15, OTN15*

OT90

OT500

OTS15

OTS90

OTS500

OT20, OTN20*

OT100

OT600

OTS20

OTS100

0TS600

OT25, OTN25*

OT110

OTS25

OTS110

Fuse

250V

B

Catalog Number

Ampere

600V

A variety of pole configurations and termination
provisions are available. Refer to Section H for details.

* In Canada

Dimensions
A

Ampere
Rating

in

B

C

D

E

mm

in

mm

in

mm

in

mm

in

mm

250V-OT, OTN Fuses
0-30

2

51

9/16

14

-

-

-

-

-

-

31-60

3

76

13/16

21

-

-

-

-

-

-

61-100

5-7/8

149

1-1/16

27

1/8

3

3/4

19

1

25

101-200

7-1/8

181

1-9/16

40

3/16

5

1-1/8

28

1-3/8

35

201-400

8-5/8

219

2-1/16

53

1/4

6

1-5/8

41

1-7/8

48

401-600

10-3/8

264

2-9/16

66

1/4

6

2

51

2-1/4

57

600V-OTS Fuses
0-30

5

127

13/16

21

-

-

-

-

-

-

31-60

5-1/2

139

1-1/16

27

-

-

-

-

-

-

61-100

7-7/8

200

1-5/16

34

1/8

3

3/4

19

1

25

101-200

9-5/8

244

1-13/16

46

3/16

5

1-1/8

28

1-3/8

35

201-400

11-5/8

295

2-9/16

66

1/4

6

1-5/8

41

1-7/8

48

401-600

13-3/8

340

3-1/8

80

1/4

6

2

51

2-1/4

57

0-60A
61-600A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

B21

RF/RFS Class H
Traditional protection for circuits with less than 10,000A
RF and RFS general purpose fuses are suitable for applications where available short
circuit currents do not exceed 10,000 amperes. RF and RFS renewable fuses use
matched RL and RLS die-cut zinc links from 1 to 600 amperes in
32 ratings.

Features/Benefits:

•• Knurled bushings for ease of disassembly
•• Rugged construction for maximum service life
•• Precision die-cut renewal links renew quickly and give repeatable
performance

Highlights:

Applications:

•• Renewable
•• 32 Renewable link ratings

•• General purpose loads where
short circuits are 10,000 amperes
or less

Ratings:

RF
Volts	 : 250VAC
Amps	 : 1 to 600A
IR	
: 10kA I.R. AC
RFS
	
Volts	 : 600VAC
Amps:	 : 1 to 600A
IR	
: 10kA I.R. AC

Approvals:

•• UL listed to standard 248-7 File
E2137

•• CSA certified to standard C22.2
no. 248.7

B22

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

RF/RFS Class H
Catalog Numbers (amps)
600V

RF1/RL1

RF45/RL45

RF225/RL225

RFS1/RLS1

RFS45/RLS45

RFS225/RLS225

RF2/RL2

RF50/RL50

RF250/RL250

RFS2/RLS2

RFS50/RLS50

RFS250/RLS250

RF3/RL3

RF60/RL60

RF300/RL300

RFS3/RLS3

RFS60/RLS60

RFS300/RLS300

RF5/RL5

RF70/RL70

RF350/RL350

RFS5/RLS5

RFS70/RLS70

RFS350/RLS350

RF6/RL6

RF80/RL80

RF400/RL400

RFS6/RLS6

RFS80/RLS80

RFS400/RLS400

RF10/RL10

RF90/RL90

RF450/RL450

RFS10/RLS10

RFS90/RLS90

RFS450/RLS450

RF15/RL15

RF100/RL100

RF500/RL500

RFS15RLS15

RFS100/RLS100

RFS500/RLS500

RF20/RL20

RF110/RL110

RF600/RL600

RFS20/RLS20

RFS110/RLS110

RFS600/RLS600

RF25/RL25

RF125/RL125

RFS25/RLS25

RFS125/RLS125

RF30/RL30

RF150/RL150

RFS30/RLS30

RFS150/RLS150

RF35/RL35

RF175/RL175

RFS35/RLS35

RFS175/RLS175

RF40/RL40

RF200/RL200

RFS40/RLS40

RFS200/RLS200

Catalog Number

Ampere
Fuse

250V

B

250V

Recommended Fuse Blocks With
Box Connectors For Renewable
Class H
600V

Rating

1-Pole

3-Pole

1-Pole

3-Pole

0-30

20306

20308

60306

60308

31-60

20606

20608

60606

60608

61-100

21036

21038

61036

61038

101-200

22001

22003

62001

62003

201-400

24001

24003

64001

64003

401-600

2631

2633

6631

6633

A variety of pole configurations and termination
provisions are available. Refer to Section H for details.

Note: Order RF/RFS for Class H Renewable Fuse Order RL/RLS for Renewable Fuse Links

Dimensions
A

Ampere
Rating

in

B

C

D

E

mm

in

mm

in

mm

in

mm

in

mm

250V-RF Fuses
0-30

2

51

9/16

14

-

-

-

-

-

-

31-60

3

76

13/16

21

-

-

-

-

-

-

61-100

5-7/8

149

1-1/16

27

1/8

3

3/4

19

1

25

101-200

7-1/8

181

1-9/16

40

3/16

5

1-1/8

28

1-3/8

35

201-400

8-5/8

219

2-1/16

53

1/4

6

1-5/8

41

1-7/8

48

401-600

10-3/8

264

2-9/16

66

1/4

6

2

51

2-1/4

57

600V-RFS Fuses
0-30

5

127

13/16

21

-

-

-

-

-

-

31-60

5-1/2

139

1-1/16

27

-

-

-

-

-

-

61-100

7-7/8

200

1-5/16

34

1/8

3

3/4

19

1

25

101-200

9-5/8

244

1-13/16

46

3/16

5

1-1/8

28

1-3/8

35

201-400

11-5/8

295

2-9/16

66

1/4

6

1-5/8

41

1-7/8

48

401-600

13-3/8

340

3-1/8

80

1/4

6

2

51

2-1/4

57

0-60A
61-600A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

B23

Plug Fuses
Plug Fuses: G/GP/TD/GW/GTL/GT/GSL
Mersen Plug Fuses are for industrial and residential applications. Standard non-time
delay fuses are for receptacle and lighting circuits. Standard time delay fuses are for
motor loads. For Canadian requirements, a type “P” fuse is used for non-motor loads
and type “D” fuses are used for electric heating and cycling loads circuits. Both fuses
have low melting-point temperature elements. Low-Temp time delay plug fuses have
thermal sensitivity are also for cycling loads and motor circuits. Type “S” plug fuses
are time delay and tamper-resistant.

Catalog Numbers (amps)
Catalog Number
Edison Base

Type S

Non-Time

Non-Time

Time-delay

”P” Type Non-time

Low-Temp

“D” Type Time-

Rejection*

Delay UL

Delay CSA

UL

Delay CSA

Time-delay UL

delay CSA

Time-delay UL

GW3

G3

-

-

-

-

-

GW6

G6

-

-

-

-

-

GW10

G10

-

-

-

-

-

GW15

-

GTL15

GP15

GT15

TD15

GSL15

GW20

-

GTL20

GP20

GT20

TD20

GSL20

GW25

-

GTL25

GP25

GT25

TD25

GSL25

GW30

-

GTL30

GP30

GT30

TD30

GSL30

Ratings:

Volts	 : 125VAC
Amps	 : 3 to 30A
IR	
: 10kA I.R. AC
Choice of Edison Base, Types “P”,
“D”, or “S”

FR15 Rejector Rings available
FRW Rejection removal tool available to remove FR15
*Must be used with an SAG adaptor to fit an Edison base fuse holder.	

Type S Plug Fuse Adaptors
Cat.No./Rating

Fuse Range - Amps

SAG3-2/10

1-8/10 - 3-2/10

SAG6-1/4

3-1/2 - 6-1/4

SAG15

7 - 15

SAG20

20

SAG30

25 - 30

•• UL Listed Guide JEFV, File
E76208

Type S adaptors screw into the Edison
base and allow Type S fuses to be
installed. Type S adaptors prevent the
wrong ampere size fuse from being
used.

B24

Approvals:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

•• CSA Certified Class 142301,
File 15525

www.barr-thorp.com

Midget, Miniature & PC
Mount Fuses
Maximum Protection.
Minimum Space.

C

Your problem: As
different as their
are on paper

C
	

— today’s

Midget

job descriptions

maintenance

Midget, Miniature & PC .
Mount Fuses

• ATQ Time-Delay................................ C2

crews, specifying
engineers, and

• ATM Fast-Acting................................ C3

OEM designers

• TRM Time-Delay............................... C4

have one thing
in common: They’re all working with smaller electrical system
components. Be it motor starters, transformers, or circuit-control

• OTM Fast-Acting............................... C5
• DCT Special Purpose........................ C6

equipment. So, where do you turn for small dimension fuses

• FSM Multi-Meter Fuse....................... C7

without a reduction in protective capacity?

• GGU Fast-Acting............................... C8

Our solution: Our international range of midget and miniature

• GFN Indicating Time-Delay............... C9

dimension and new PC mount fuses offers you all the protection

• SBS Fast-Acting.............................. C10

you require. A wide range of ratings. Special characteristics like

PC Mount

time-delay and low I t. All within a footprint of 1-1/2” x 13/32”
2

or less.

• PCF; PCS; PCT............................... C11
Miniature

Want more information fast? For more technical or application-

• GSA/GSA-V; GDL/GDL-V............... C15

specific information, please call our Midget and Miniature

• GGC/GGC-V; GGM/GGM-V............ C16

Dimension fuse experts, at 978-462-6662; 416-252-9371 in
Canada; or visit our website at us-ferrazshawmut.mersen.com.

• GGA/GGA-V; GSC/GSC-V.............. C17
• GSB/GSB-V; GDG/GDG-V.............. C18
• GSD/GSD-V; GSF/GSF-V............... C19
• GGX; GAB; GSR-V......................... C20
• SMG/SMG-V; STG/STG-V.............. C21
• Radial Lead Micro Fuses MRF, MRT.. C22
• SFRT; SFRB; SFRG; FSFE, SFRU .. C23
• SLR, SMF, SHR.............................. C24
• Automotive Fuses - AF, AF2, AF3,
AFH20, AFH30, AF2H30,AF3H60... C26

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

ATQ Time-Delay Midget Fuses
Amp-Trap® ATQ midget time-delay fuses are rated a full 500 volts AC with 42 ampere
ratings from 1/10 to 30A. They are an excellent choice for supplemental protection of
circuits up to 30A where the available short circuit current does not exceed 10,000A.
(Not for Branch Circuit Protection).

Features/Benefits:
••
••
••
••

Numerous ratings for a wide variety of applications up to 500VAC
Time-delay (12 seconds at 200% rating) for circuits with high inrush current
Can be used with UltraSafe™ Fuse holders
1 1/2” x 13/32” (10mm x 38mm) dimensions

Highlights:

Applications:

•• Time-delay

•• Supplemental protection of
lighting, solenoid, motor and
transformer circuits

Ratings:
Volts	

Catalog Numbers (amps)

: 500VAC

Amps	 : 1/10 to 30A

ATQ1/10

ATQ3/10

ATQ1-1/8

ATQ2

ATQ3-2/10

ATQ6

ATQ12

ATQ1/8

ATQ4/10

ATQ1-1/4

ATQ2-1/8

ATQ3-1/2

ATQ6-1/4

ATQ14

ATQ15/100

ATQ1/2

ATQ1-4/10

ATQ2-1/4

ATQ4

ATQ7

ATQ15

ATQ3/16

ATQ6/10

ATQ1-1/2

ATQ2-1/2

ATQ4-1/2

ATQ8

ATQ20

ATQ2/10

ATQ8/10

ATQ1-6/10

ATQ2-8/10

ATQ5

ATQ9

ATQ25

ATQ1/4

ATQ1

ATQ1-8/10

ATQ3

ATQ5-6/10

ATQ10

ATQ30

I.R.	

: 10kA I.R.

Recommended Fuse Blocks for Midget
(10x38mm) Fuses
Catalog Number
Number of
Poles

UltraSafeTM
Indicating
Fuse Holder

Adder

C2

Screw
Connector
30310

Pressure
Plate
Connector
30320

Approvals:
Copper Box
Connector
30350

1

USM1I

30311

30321

30351

2

USM2I

30312

30322

30352

3

USM3I

30313

30323

30353

3

USFM10I

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

•• UL listed to standard 248-14
File E33925

•• CSA Certified to Standard
C22.2 No. 248.14

www.barr-thorp.com

ATM Fast-Acting Midget Fuses
Amp-Trap® midget fast-acting ATM fuses are rated 600 volts AC and DC, with a
100kA interrupting rating. These ratings give the ATM a wide range of applications
not covered by other midget fuses. In addition, ratings of 30/35, 30/40 and 30/50
amperes are offered for specific applications such as capacitor protection. These ATM
fuses must still be considered 30A fuses because of their dimensions, but are able
to withstand much higher inrush currents and tougher duty cycles. (Not for Branch

C

Circuit Protection).

Features/Benefits:

•• For supplemental protection of small motors and transformers
•• Extended ratings for special protection of capacitors and circuits
with high inrush currents

•• 600VDC ratings for a wide variety of applications including
photovoltaic and solar applications.

•• Can be used with UltraSafe™ fuse holders
•• 1 1/2” x 13/32” (10mm x 38mm) dimensions

Highlights:

Ratings:

Applications:

•• Fast-acting
•• Special Ratings (Above 30A)

•• Supplemental protection of
of circuits up to 600VAC and
600VDC with 100kA I.R.

Catalog Numbers (amps)
ATM1/10

ATM6

ATM1/8

ATM7

ATM2/10

ATM8

ATM1/4

ATM10

ATM1/2

ATM12

ATM3/4

ATM15

ATM1

ATM20

ATM1-1/2

ATM25

ATM2

ATM30

ATM3

ATM30/35*

ATM4

ATM30/40*

ATM5

ATM30/50*

Volts	

: 600VAC / DC

Amps	 : 1/10 to 30A
	

: (35 to 50A AC only)

I.R.	

: 100kA I.R.

	

: 10kA I.R. AC (35 to 50A)

Approvals:

•• UL listed to standard 248-14
(1/10 to 30A) File E33925

•• DC Listed to UL Standard
248-14 (1/10 to 30A)

•• CSA Certified to Standard

* are not continuous current rated devices

C22.2 No. 248.14 (1/10 to 30A)

Recommended Fuse Blocks for Midget
(10x38mm) Fuses
Catalog Number
Number of
Poles

UltraSafeTM
Indicating
Fuse Holder

Adder

Screw
Connector

Pressure
Plate
Connector

Copper Box
Connector

30310

30320

30350

1

USM1I

30311

30321

30351

2

USM2I

30312

30322

30352

3

USM3I

30313

30323

30353

3

USFM10I

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

C3

TRM Time-Delay Midget Fuses
Tri-Onic® TRM time-delay midget fuses are rated 250 volts AC and are offered in
ampere ratings from 1/10 to 30A. They have 12 seconds time-delay at 200% rating
to provide supplemental protection of small motors, small transformers and other
high inrush loads, plus many other 250 volt applications. (Not for Branch Circuit
Protection).

Features/Benefits:
••
••
••
••
••

Numerous ratings for a wide variety of applications
250VAC rating in all sizes up to 30A
Time-delay for circuits with high inrush currrent
Can be used with UltraSafeTM fuse holders
1 1/2” x 13/32” (10mm x 38mm) dimensions

Highlights:

Applications:

•• Time-delay

••
••
••
••

Small motors
Small transformers

Ratings:

Lighting circuits

Volts	

Control circuits

Amps	 : 1/10 to 30A
I.R.	

: 250VAC
: 10kA I.R.

Catalog Numbers (amps)
TRM1/10

TRM6/10

TRM1-6/10

TRM3

TRM5-6/10

TRM10

TRM15/100

TRM8/10

TRM1-8/10

TRM3-2/10

TRM6

TRM12

TRM2/10

TRM1

TRM2

TRM3-1/2

TRM6-1/4

TRM15

TRM1/4

TRM1-1/8

TRM2-1/4

TRM4

TRM7

TRM20

TRM3/10

TRM1-1/4

TRM2-1/2

TRM4-1/2

TRM8

TRM25

TRM4/10

TRM1-4/10

TRM2-8/10

TRM5

TRM9

TRM30

TRM1/2

Approvals:

Recommended Fuse Blocks for Midget
(10x38mm) Fuses

•• UL listed to standard 248-14
File E33925	

•• CSA Certified to Standard

Catalog Number
Number of
Poles

UltraSafeTM
Indicating
Fuse Holder

Adder
1

C4

Screw
Connector

Pressure
Plate
Connector

C22.2 No. 248.14
Copper Box
Connector

30310

30320

30350

USM1I

30311

30321

30351

2

USM2I

30312

30322

30352

3

USM3I

30313

30323

30353

3

USFM10I

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

OTM Fast-Acting Midget Fuses
One-time OTM midget fuses provide low-cost protection for 250 volt AC general
purpose lighting, heating, control circuits, etc. where time-delay is not required.
(Not for Branch Circuit Protection).

Features/Benefits:

Highlights:

C

•• Low cost and fully rated for economy without compromise
•• Can be used with UltraSafe™ fuse holders
•• 1 1/2” x 13/32” (10mm x 38mm) dimensions

Applications:

•• Fast-acting

•• Supplemental protection of
circuits up to 250VAC and 10kA

Catalog Numbers (amps)

Ratings:

OTM1

Volts	

OTM2

: 250VAC

Amps	 : 1 to 30A

OTM3

I.R.	

OTM4

: 10kA I.R.

OTM5
OTM6
OTM8
OTM10
OTM15
OTM20
OTM25
OTM30

Approvals:

Recommended Fuse Blocks for Midget
(10x38mm) Fuses

•• UL Listed to standard 248-14
File E33925	

•• CSA Certified to Standard C22.2

Catalog Number
Number of
Poles

UltraSafeTM
Indicating Fuse
Holder

Adder

Screw

Pressure Plate

Copper Box

Connector

Connector

Connector

30310

30320

30350

1

USM1I

30311

30321

30351

2

USM2I

30312

30322

30352

3

USM3I

30313

30323

30353

3

USFM10I

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

No. 248.14

www.barr-thorp.com

C5

DCT Special Purpose Midget Fuses
Mersen DCT fuses were developed to meet requirements coming from new
applications such as protection of photovoltaic cells, multi meters and compact on
board traction equipment for auxiliary circuits. This high performance DC fuse in its
compact size offers multiple competitive advantages particularly for international
applications where DC voltage requirements are above 600V DC.

Features/Benefits:
••
••
••
••
••

Low minimum breaking capacity (MBC)
Compact size: 10 x 38 mm (13/32” x 1-1/2”) size internationally accepted.
Ferrule mount 1 to 30A for design versatility
Can be used with UltraSafeTM fuse holders USM series
1 1/2” x 13/32” (10mm x 38mm) dimensions

Highlights:

Applications:

•• 750VAC / 1000VDC
•• DC : L/R = 1mS

••
••
••
••

DC traction equipment
Multi-meters

Ratings:

Photovoltaic systems

Volts	

: 750VAC

Semiconductor protection

	

: 1000VDC

Amps	 : 1 to 30A

Catalog Numbers, I 2t
(at 50,000 Amps –1000VDC L/R = 1ms)

I.R.	

: 100kA I.R. AC

	

: 50kA I.R. DC

Catalog

Clearing

Watts Loss @ 80%

Watts Loss @ 100%

MBC	

Number

I2t(A2s)

Rating (W)

Rating (W)

: 2.0 x In (AC)

DCT1-2

-

0.2

0.32

	

: 1.3 x In (DC : 1 - 7A)

DCT2-2

-

0.27

0.43

	

: 2.0 x In (DC : 8 - 30A)

DCT3-2

-

0.9

1.4

L/R	

: 1mS

DCT4-2

-

0.8

1.3

DCT5-2

-

0.9

1.4

DCT6-2

-

1.0

1.5

DCT7-2

-

1.1

1.5

DCT8-2

83

0.7

1.1

DCT10-2

127

0.9

1.5

DCT12-2

215

1.3

2.0

DCT15-2

495

1.9

3.0

DCT20-2

755

2.6

4.4

DCT25-2

970

2.9

5.3

DCT30-2

1650

3.0

5.8

Approvals:

•• UL Recognized component File
E60314

Recommended Fuse Blocks for Midget (10x38mm) Fuses
Catalog Number
Number of

UltraSafeTM

Screw

Poles

Fuse Holder

Connector

Adder

C6

Pressure
Plate
Connector

Copper Box
Connector

30310

30320

30350

1

USM1

30311

30321

30351

2

USM2

30312

30322

30352

3

USM3

30313

30323

30353

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

FSM Multi-Meter Fuse
Mersen has developed a true 1000V AC/DC fuse designed to protect both analog and
digital multi-meters. These fuses cover all the industry’s multi-meter requirements
in three easy to use amperage ratings. Good for 1000V AC and DC, the FSM line of
Mersen fuses are designed for the power electronics metering and controls market.

Features/Benefits:

C

•• For the protection of multi-meters
•• 1000V AC/DC for full range protection
•• 100% Current rated for continuous current with
L/R = 10mS carrying capability

•• Glass melamine body and plated terminals provide superior reliability
and performance

Applications

Highlights:

•• Multi-meters

•• Fast-acting
•• Current-limiting

Ratings:
Volts	

: 1000VAC / DC

Amps	 : 44/100A, 11A, 15A

Catalog Numbers (amps)

Cross Reference

I.R.	

: 20kA I.R.

Mersen FSM replaces the

FSM44/100

Bussmann: DMM-B

FSM11

Littelfuse: FLU

FSM15

Dimensions
Catalog No.

A

FSM44/100

1.375”

B
0.406”

FSM11

1.500”

0.406”

FSM15

1.500”

0.406”

Approvals:

•• UL Recognized component File
E60314

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

C7

GGU Fast-Acting Midget Fuses
125 volt AC rated GGU fuses have midget fuse dimensions (1-1/2” long x 13/32”
diameter). 20A-30A ratings have ceramic bodies, allowing use in higher ambient
temperature conditions than other similar fuses. (Not for Branch Circuit Protection).

Features/Benefits:
••
••
••
••
••

Glass body on 1-15A makes status of fusible element clearly visible
Ceramic body on 20-30A allows use in higher temperature applications
Medium lag for protection of circuits up to 30A and 125VAC
Can be used with UltraSafe™ fuse holders (1-30A)
1 1/2” x 13/32” (10mm x 38mm) dimensions

Highlights:
•• Fast-acting

Catalog Numbers (amps)

Ratings:

GGU1

Volts	

GGU2

: 125VAC

Amps	 : 1 to 30A

GGU3

I.R.	

GGU4

: 10kA I.R.

GGU5
GGU8
GGU10
GGU15
GGU20
GGU30

Recommended Fuse Blocks for Midget
(10x38mm) Fuses
Approvals:

Catalog Number
Number of
Poles

UltraSafeTM
Indicating

Copper Box

Connector

Connector

30310

30320

30350

Screw Connector

Fuse Holder

Adder

C8

Pressure Plate

1

USM1I

30311

30321

30351

2

USM2I

30312

30322

30352

3

USM3I

30313

30323

30353

3

USFM10I

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

•• UL Listed 1-15A
•• UL Recognized 20-30A

www.barr-thorp.com

GFN Time-Delay Midget Fuses
GFN midget indicating fuses are available in ratings from 1/10 through 30A. These
time-delay fuses have built-in blown fuse indicators which pop out at the end of the
fuse to visually indicate when the fuse has operated to open the circuit. Indicators
may be used to trip a switch for remote as well as visual annunciation.
(Not for Branch Circuit Protection).

C

Features/Benefits:

•• Pin indicator provides visual indication of open fuse or actuates switch for
••
••
••
••

remote signaling
Numerous ratings for a wide variety of applications
12 second time-delay at 200% rating
Can be used with UltraSafe™ fuse holders (1/10 - 10A)
1 1/2” x 13/32” (10mm x 38mm) dimensions

Applications:

Highlights:

•• For supplemental protection of

•• Pin indicator
•• Time-delay
•• 12-30A double body

circuits where time-delay and

Volts	

blown fuse indication are required,

	: 125VAC (12 - 15A)

such as solenoid circuits or

	

: 250VAC (0.1 - 10A)
: 32VAC (20 - 30A)

Amps	 : 1/10 to 30A

control circuits.

I.R.	

Catalog Numbers (amps)

: 200kA I.R., 250VAC, 0.1-10A

	: 10kA I.R., 125VAC, 0.1-15A

GFN1/10

GFN1

GFN2-1/2

GFN6-1/4

GFN1/8

GFN1-1/8

GFN2-8/10

GFN7

GFN15/100

GFN1-1/4

GFN3

GFN8

GFN2/10

GFN1-4/10

GFN3-2/10

GFN10

GFN1/4

GFN1-1/2

GFN3-1/2

GFN12*

GFN3/10

GFN1-6/10

GFN4

GFN15*

GFN4/10

GFN1-8/10

GFN4-1/2

GFN20*

GFN1/2

GFN2

GFN5

GFN25*

GFN6/10

GFN2-1/4

GFN5-6/10

GFN30*

GFN8/10

Ratings:

	

: 10kA I.R., 32VAC, 20-30A

Approvals:

•• UL Listed to standard 248-14

GFN6

(1/10 to 15A) File E33925

•• CSA Certified to Standard

*Note: 12-30A is a double barrel fuse construction

C22.2 No. 248.14 (1/10 to 15A)

Recommended Fuse Blocks for Midget (10x38mm) Fuses
Catalog Number
Number of

UltraSafeTM Indicating

Poles

Fuse Holder

Adder

Pressure Plate

Copper Box

Connector

Connector

30310

30320

30350

Screw Connector

1

USM1I

30311

30321

30351

2

USM2I

30312

30322

30352

3

USM3I

30313

30323

30353

3

USFM10I

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

C9

SBS Fast-Acting Ferrule Fuses
Unique dimensions for today’s smaller equipment and components. Fast-acting
general purpose fuse developed in response to the industry’s demand for smaller
equipment and components. The only fuse in their size with a full 600 VAC rating for
all ampere ratings by UL standard 248-14 and CSA No. 59.2, and are the only fuses of
this size with an interrupting rating of 100kA RMS. SBS fuses are 1-3/8” long, smaller
by 1/8” than most standard midget fuses and are available in 22 ampere ratings, from
2/10A to 30A. (Not for Branch Circuit Protection).

Features/Benefits:

•• Small unique physical size for maximum design flexibility and noninterchangeability with other fuse classes

•• Fiberglass body provides dimensional stability in harsh industrial
environments

•• Can be used with UltraSafeTM fuse holder
•• 1 3/8” x 13/32” dimensions

Highlights:

Applications:

•• Fast-acting
•• Unique dimensions

••
••
••
••
••

Catalog Numbers (amps)

C10

SBS2/10

SBS1-8/10

SBS10

SBS4/10

SBS2

SBS12

SBS1/2

SBS3

SBS15

SBS3/4

SBS4

SBS20

SBS8/10

SBS5

SBS25

SBS1

SBS6

SBS30

SBS1-1/2

SBS7

SBS1-6/10

SBS8

Control circuits
Lighting ballasts

Ratings:
Volts	

: 600VAC

Amps	 : 2/10 to 30A
I.R.	

: 100kA I.R.

Meter circuits
Electronic circuits
General purpose protection

Cross Reference:
SBS will replace Bussmann BBS,
Littelfuse BLS fuses

Approvals:

•• UL Listed to standard 248-14
File E33925

•• CSA Certified to Standard C22.2
No. 248.14

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

PCF Fast-Acting PC Mount Fuses
Fast-acting fuses for direct mounting on printed circuit
boards.
Mersen’s PCF series of fast-acting direct-mountable fuses addresses the increasing
need for electrical protection at the PC board as current and voltage requirements
push higher. These fuses help printed circuit board manufacturers reduce parts by
eliminating clips and fuse blocks and allowing automated assembly. PCF fuses can

C

be used for the protection of main frame power boards, small circuit breakers with
low-interrupting ratings and other critical components. PCF fuses bring greatlyincreased ampere, voltage and interrupting ratings to the board itself and are UL
Component Recognized.

Highlights:

•• Fast-acting
•• PC board mount
•• Three mounting styles

Applications:

•• Protection of main frame
power boards, circuit breakers,
components

Catalog Numbers (amps)
Slot Mount
PCF1-R

PCF8-R

PCF2-R

PCF10-R

PCF3-R

PCF12-R

PCF4-R

PCF15-R

PCF5-R

PCF20-R

PCF6-R

PCF25-R

PCF7-R

PCF30-R

Ratings:
Volts	

: 600VAC / DC

Amps	 : 1 to 30A
I.R.	

: 100kA I.R.

L/R	

: ≤10ms

Double Hole Mount
PCF1-H

PCF8-H

PCF2-H

PCF10-H

PCF3-H

PCF12-H

PCF4-H

PCF15-H

PCF5-H

PCF20-H

PCF6-H

PCF25-H

PCF7-H

PCF30-H

Approvals:

•• UL Recognized Components
File E60314

PCF30/50-H
Surface Mount
PCF1-S

PCF8-S

PCF2-S

PCF10-S

PCF3-S

PCF12-S

PCF4-S

PCF15-S

PCF5-S

PCF20-S

PCF6-S

PCF25-S

PCF7-S

PCF30-S

Dimensions of the PCF Series are found on page C14

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

C11

PCS Semiconductor PC Mount Fuses
Semiconductor protection fuses for direct mounting on
printed circuit boards.
Mersen’s PCS series of extremely fast-acting, direct-mountable fuses address the
increasing need for electrical protection at the PC board as current and voltage
requirements push higher. These fuses help printed circuit board manufacturers
reduce parts by eliminating clips and fuse blocks and allowing automated assembly.
PCS fuses are AC and DC rated and are extremely current-limiting. They will protect
semiconductors, main frame boards, circuit breakers with low interrupting rating
and other critical components. PCS fuses bring I2t protection, higher voltage and
interrupting ratings to the board itself and are UL Component Recognized.

Highlights:

•• Extremely fast-acting
•• PC board mount
•• Three mounting styles

Catalog Numbers (amps)

Applications:

•• Protection of semiconductors,
circuit breakers, critical
components

Watts Loss Data

Slot Mount
PCS5-R

PCS20-R

PCS8-R

PCS25-R

PCS10-R

PCS30-R

PCS12-R

PCS35-R

PCS15-R

PCS40-R

Double Hole Mount
PCS5-H

PCS20-H

PCS8-H

PCS25-H

PCS10-H

PCS30-H

PCS12-H

PCS35-H

PCS15-H

PCS40-H

Volts	

Ampere

Watts Loss @

Watts Loss @

Rating

80% Rating (w)

100% Rating (w)

5

0.5

0.7

10

0.9

1.5

15

1.9

3.0

20

2.6

4.4

25

2.9

5.3

30

3.0

5.8

35

3.3

6.4

40

3.6

7.0

I t Data, 100kA

PCS5-S

PCS20-S

Ampere

PCS8-S

PCS25-S

Rating

600VAC

600VDC L/R
=10ms

Melting

Clearing

I2t (A2s)

I2t (A2s)

Clearing
I2t (A2s)

PCS10-S

PCS30-S

PCS12-S

PCS35-S

5

5

60

40

PCS15-S

PCS40-S

8

6.5

70

42

10

10

110

70

12

17

150

90

15

26

180

110

20

41

330

200

25

69

440

260

30

132

860

520

35

197

1300

780

40

276

1800

1100

Dimensions of the PCS
Series are found
on page C14

: 600VAC / DC

Amps	 : 5 to 40A
I.R.	

: 200kA I.R. AC

	

: 100kA I.R. DC

L/R	

: ≤10ms

2

Surface Mount

C12

Ratings:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Approvals:

•• UL Recognized Components
File E60314

www.barr-thorp.com

PCT Time-Delay PC Mount Fuses
Time-delay fuses for direct mounting on printed circuit boards.
Mersen’s PCT series of time-delay, direct-mountable fuses addresses the increasing
need for electrical protection at the PC board as current and voltage requirements
push higher. These fuses help printed circuit board manufacturers reduce parts by
eliminating clips and fuse blocks and allowing automated assembly. PCT fuses can
be used for the protection of main frame power boards, small circuit breakers with

C

low interrupting ratings and other components. PCT fuses bring protection with timedelay, greatly increased ampere, voltage and interrupting ratings to the board itself
and are UL Component Recognized.

Highlights:

•• Time-delay
•• PC board mount
•• Three mounting styles

Applications:

•• Protection of main frame
power boards, circuit breakers,
components

Ratings:
Catalog Numbers (amps)
Slot Mount
PCT1-R

PCT8-R

PCT2-R

PCT10-R

PCT3-R

PCT12-R

PCT4-R

PCT15-R

PCT5-R

PCT20-R

PCT6-R

PCT25-R

Volts	

: 500VAC

Amps	 : 1 to 30A
I.R.	

: 100kA I.R.

Double Hole Mount
PCT7-R

PCT30-R

PCT1-H

PCT8-H

PCT2-H

PCT10-H

PCT3-H

PCT12-H

PCT4-H

PCT15-H

PCT5-H

PCT20-H

PCT6-H

PCT25-H

Approvals:

•• UL Recognized Components
File E60314

Surface Mount
PCT7-H

PCT30-H

PCT1-S

PCT8-S

PCT2-S

PCT10-S

PCT3-S

PCT12-S

PCT4-S

PCT15-S

PCT5-S

PCT20-S

PCT6-S

PCT25-S

PCT7-S

PCT30-S

Dimensions of the PCT Series are found on page C14

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

C13

PCF/PCS/PCT Series PC Mount Fuses
Outline Dimensions
Slot Mount (Rectangular Holes)

PCF1-R thru PCF30-R
PCS5-R thru PCS40-R
PCT1-R thru PCT30-R

MOUNTING HOLE DETAIL

FOR .062 (1.6) NOMINAL
CIRCUIT BOARD
THICKNESS

Double Hole Mount (Round Holes)

PCF1-H thru PCF30-H
PCS5-H thru PCS40-H
PCT1-H thru PCT30-H

MOUNTING HOLE DETAIL

FOR .062 (1.6) NOMINAL
CIRCUIT BOARD
THICKNESS

Surface (Screw) Mount

PCF1-S thru PCF30-S
PCS5-S thru PCS40-S
PCT1-S thru PCT30-S

Maximum Recommended
Screw Size 3.5mm

C14

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Electronic/Glass Fuses
••
••
••
••

GDL/GDL-V
••
••
••
••

Ceramic body
Time-delay
1/4” x 1-1/4”
1-1/2” Axial leads optional

Glass body
Time-delay
1/4” x 1-1/4”
1-1/2” Axial leads optional

1/16A through 8A, 250VAC, UL Listed -

1/16A through 8A, 250VAC, UL Listed and CSA Certified

10,12,15A, 250V UL Recognized

10A through 15A, 125VAC, UL Listed and CSA Certified

1/16A through 8A, 250VAC, CSA Certified - 10, 12, 15A,

20A through 30A, 32VAC, UL Listed to U.S. and

250V CSA Recognized 20A, 250VAC, 25 & 30A, 125VAC

Canadian safety standards

Standard Fuse Ampere Ratings

Standard Fuse Ampere Ratings

1.
2.
3.
4.
5.
6.

Catalog
Number

Axial Lead
Cat. No

Ampere
Rating

Volts

I.R.

Catalog
Number

Axial Lead
Cat. No

Ampere
Rating

Volts

I.R.

GSA1/16
GSA1/10
GSA1/8
GSA15/100
GSA175/1000
GSA3/16
GSA2/10
GSA1/4
GSA3/10
GSA3/8
GSA4/10
GSA1/2
GSA6/10
GSA7/10
GSA3/4
GSA8/10
GSA1
GSA1-1/4
GSA1-1/2
GSA1-6/10
GSA2
GSA2-1/4
GSA2-1/2
GSA2-8/10
GSA3
GSA3-2/10
GSA3-1/2
GSA4
GSA5
GSA6
GSA6-1/4
GSA7
GSA8
GSA10
GSA12
GSA15
GSA20
GSA25
GSA30

GSA-V1/16
GSA-V1/10
GSA-V1/8
GSA-V15/100
GSA-V175/1000
GSA-V3/16
GSA-V2/10
GSA-V1/4
GSA-V3/10
GSA-V3/8
GSA-V4/10
GSA-V1/2
GSA-V6/10
GSA-V7/10
GSA-V3/4
GSA-V8/10
GSA-V1
GSA-V1-1/4
GSA-V1-1/2
GSA-V1-6/10
GSA-V2
GSA-V2-1/4
GSA-V2-1/2
GSA-V2-8/10
GSA-V3
GSA-V3-2/10
GSA-V3-1/2
GSA-V4
GSA-V5
GSA-V6
GSA-V6-1/4
GSA-V7
GSA-V8
GSA-V10
GSA-V12
GSA-V15
GSA-V20
GSA-V25
GSA-V30

1/16A
1/10A
1/8A
15/100A
175/1000A
3/16A
2/10A
1/4A
3/10A
3/8A
4/10A
1/2A
6/10A
7/10A
3/4A
8/10A
1A
1-1/4A
1-1/2A
1-6/10A
2A
2-1/4A
2-1/2A
2-8/10A
3A
3-2/10A
3-1/2A
4A
5A
6A
6-1/4A
7A
8A
10A
12A
15A
20A
25A
30A

250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
125V
125V

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
4
4
4
5
6
6

GDL1/16
GDL1/10
GDL1/8
GDL15/100
GDL175/1000
GDL3/16
GDL2/10
GDL1/4
GDL3/10
GDL3/8
GDL4/10
GDL1/2
GDL6/10
GDL7/10
GDL3/4
GDL8/10
GDL1
GDL1-1/4
GDL1-1/2
GDL1-6/10
GDL1-8/10
GDL2
GDL2-1/4
GDL2-1/2
GDL2-8/10
GDL3
GDL3-2/10
GDL4
GDL5
GDL6
GDL6-1/4
GDL7
GDL8
GDL10
GDL12
GDL15
GDL20
GDL25
GDL30

GDL-V1/16
GDL-V1/10
GDL-V1/8
GDL-V15/100
GDL-V175/1000
GDL-V3/16
GDL-V2/10
GDL-V1/4
GDL-V3/10
GDL-V3/8
GDL-V4/10
GDL-V1/2
GDL-V6/10
GDL-V7/10
GDL-V3/4
GDL-V8/10
GDL-V1
GDL-V1-1/4
GDL-V1-1/2
GDL-V1-6/10
GDL-V1-8/10
GDL-V2
GDL-V2-1/4
GDL-V2-1/2
GDL-V2-8/10
GDL-V3
GDL-V3-2/10
GDL-V4
GDL-V5
GDL-V6
GDL-V6-1/4
GDL-V7
GDL-V8
GDL-V10
GDL-V12
GDL-V15
GDL-V20
GDL-V25
GDL-V30

1/16A
1/10A
1/8A
15/100A
175/1000A
3/16A
2/10A
1/4A
3/10A
3/8A
4/10A
1/2A
6/10A
7/10A
3/4A
8/10A
1A
1-1/4A
1-1/2A
1-6/10A
1-8/10A
2A
2-1/4A
2-1/2A
2-8/10A
3A
3-2/10A
4A
5A
6A
6-1/4A
7A
8A
10A
12A
15A
20A
25A
30A

250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
125V
125V
125V
32V
32V
32V

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
4
4
4
5
5
5

250VAC @ 35A I.R./125VAC @ 10kA I.R.
250VAC @ 100A I.R./125VAC @ 10kA I.R.
250VAC @ 200A I.R./125VAC @ 10kA I.R.
250VAC @ 750A I.R./125VAC @ 10kA I.R.
250VAC @ 400A I.R./125VAC @ 10KA I.R.
125VAC @ 400A I.R.

1.
2.
3.
4.
5.

C

GSA/GSA-V

250VAC @ 35A I.R./125VAC @ 10kA I.R.
250VAC @ 100A I.R./125VAC @ 10kA I.R.
250VAC @ 200A I.R./125VAC @ 10kA I.R.
125VAC @ 10kA I.R.
32VAC @ 300A I.R.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

C15

Electronic/Glass Fuses
GGC/GGC-V
••
••
••
••

GGM/GGM-V
••
••
••
••

Glass body
Fast-acting
1/4” x 1-1/4”
1-1/2” Axial leads optional

Glass body
Fast-acting
5mm x 20mm
1-1/2” Axial leads optional

1/10A through 10A, 250VAC,

1/16A through 3A, 250VAC,

UL Listed and CSA Certified

UL Listed and CSA Certified 4A

12A and 15A, 125VAC, UL Listed

through 8A, 125VAC, UL Listed and

and CSA Certified - 20A through 30A, 32VAC

CSA Certified - 10A and 15A, 250VAC, UL Recognized

Standard Fuse Ampere Ratings

Standard Fuse Ampere Ratings

2.
3.
4.
5.

C16

Catalog

Axial Lead

Ampere

Number

Cat. No

Rating

GGC1/10
GGC1/8
GGC15/100
GGC175/1000
GGC3/16
GGC2/10
GGC1/4
GGC3/10
GGC3/8
GGC4/10
GGC1/2
GGC6/10
GGC3/4
GGC8/10
GGC1
GGC1-1/4
GGC1-1/2
GGC1-3/4
GGC1-6/10
GGC2
GGC2-1/4
GGC2-1/2
GGC3
GGC3-2/10
GGC4
GGC5
GGC6
GGC6-3/10
GGC7
GGC7-1/2
GGC8
GGC10
GGC12
GGC15
GGC20
GGC25
GGC30

GGC-V1/10
GGC-V1/8
GGC-V15/100
GGC-V175/1000
GGC-V3/16
GGC-V2/10
GGC-V1/4
GGC-V3/10
GGC-V3/8
GGC-V4/10
GGC-V1/2
GGC-V6/10
GGC-V3/4
GGC-V8/10
GGC-V1
GGC-V1-1/4
GGC-V1-1/2
GGC-V1-3/4
GGC-V1-6/10
GGC-V2
GGC-V2-1/4
GGC-V2-1/2
GGC-V3
GGC-V3-2/10
GGC-V4
GGC-V5
GGC-V6
GGC-V6-3/10
GGC-V7
N/A
GGC-V8
GGC-V10
GGC-V12
GGC-V15
GGC-V20
GGC-V25
GGC-V30

1/10A
1/8A
15/100A
175/1000A
3/16A
2/10A
1/4A
3/10A
3/8A
4/10A
1/2A
6/10A
3/4A
8/10A
1A
1-1/4A
1-1/2A
1-3/4A
1-6/10A
2A
2-1/4A
2-1/2A
3A
3-2/10A
4A
5A
6A
6-3/10A
7A
7-1/2A
8A
10A
12A
15A
20A
25A
30A

Volts

I.R.

250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
125V
125V
32V
32V
32V

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
2
2
2
2
2
2
2
2
4
4
5
5
5

1.
2.
3.
4.
5.

Catalog

Axial Lead

Ampere

Number

Cat. No

Rating

GGM1/16
GGM1/10
GGM1/8
GGM2/10
GGM1/4
GGM3/10
GGM4/10
GGM1/2
GGM6/10
GGM7/10
GGM3/4
GGM8/10
GGM1
GGM1-2/10
GGM1-1/4
GGM1-1/2
GGM1-6/10
GGM2
GGM2-1/2
GGM3
GGM4
GGM5
GGM6
GGM7
GGM8
GGM10
GGM15

GGM-V1/16
GGM-V1/10
GGM-V1/8
GGM-V2/10
GGM-V1/4
GGM-V3/10
GGM-V4/10
GGM-V1/2
GGM-V6/10
GGM-V7/10
GGM-V3/4
GGM-V8/10
GGM-V1
N/A
GGM-V1-1/4
GGM-V1-1/2
GGM-V1-6/10
GGM-V2
GGM-V2-1/2
GGM-V3
GGM-V4
GGM-V5
GGM-V6
GGM-V7
GGM-V8
GGM-V10
GGM-V15

1/16A
1/10A
1/8A
2/10A
1/4A
3/10A
4/10A
1/2A
6/10A
7/10A
3/4A
8/10A
1A
1-2/10A
1-1/4A
1-1/2A
1-6/10A
2A
2-1/2A
3A
4A
5A
6A
7A
8A
10A
15A

Volts

I.R.

250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
125V
125V
125V
125V
125V
250V
250V

2
3
3
3
3
3
1
3
1
3
3
1
3
2
3
3
2
3
3
3
4
4
4
4
4
5
5

250VAC @ 35A I.R./125VAC @ 10kA I.R.
250VAC @ 100A I.R./125VAC @ 10kA I.R.
250VAC @ 200A I.R./125VAC @ 10kA I.R.
125VAC @ 10kA I.R.
250VAC @ 100A I.R.

250VAC @ 200A I.R./125VAC @ 10kA I.R.
250VAC @ 10kA I.R.
125VAC @ 10kA I.R.
32VAC @ 1000A I.R.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Electronic/Glass Fuses

••
••
••
••

GSC/GSC-V
••
••
••
••

Glass body
Time-delay
5mm x 20mm
1-1/2” Axial
leads optional

Glass / ceramic body

C

GGA/GGA-V

Time-delay
5mm x 20mm
1-1/2” Axial
leads optional

1/10 through 3A, 250VAC, UL Listed and CSA Certified

1/10A through 3A, 250VAC, UL Listed and CSA

4A and 5A, 125VAC, UL Listed and CSA Certified

Certified - 4A through 8A, 125VAC, UL Listed and CSA
Certified - 10A, 125VAC, UL and CSA Recognized

Standard Fuse Ampere Ratings
Catalog

Axial Lead

Ampere

Number

Cat. No

Rating

GGA1/10

GGA-V1/10

GGA1/8

GGA-V1/8

GGA2/10

Volts

I.R.

1/10A

250V

1

1/8A

250V

1

GGA-V2/10

2/10A

250V

1

GGA1/4

GGA-V1/4

1/4A

250V

1

GGA3/10

GGA-V3/10

3/10A

250V

1

GGA4/10

GGA-V4/10

4/10A

250V

1

GGA1/2

GGA-V1/2

1/2A

250V

1

GGA6/10

GGA-6/10

6/10A

250V

1

GGA7/10

GGA-V7/10

7/10A

250V

1

GGA3/4

GGA-V3/4

3/4A

250V

1

GGA8/10

GGA-V8/10

8/10A

250V

1

GGA1

GGA-V1

1A

250V

2

GGA1-1/4

GGA-V1-1/4

1-1/4A

250V

2

GGA1-1/2

GGA-V1-1/2

1-1/2A

250V

2

GGA1-6/10

GGA-V1-6/10

1-6/10A

250V

2

GGA2

GGA-V2

2A

250V

2

GGA2-1/2

GGA-V2-1/2

2-1/2A

250V

2

GGA3

GGA-V3

3A

250V

2

GGA4

GGA-V4

4A

125V

3

GGA5

GGA-V5

5A

125V

3

1. 250VAC @ 35A I.R./125VAC @ 10kA I.R.
2. 250VAC @ 100A I.R./125VAC @ 10kA I.R.
3. 125VAC @ 10kA I.R.

Standard Fuse Ampere Ratings
Catalog

Axial Lead

Ampere

Number

Cat. No

Rating

GSC1/10

GSC-V1/10

GSC1/8

GSC-V1/8

GSC1/4

Volts

I.R.

1/10A

250V

1

1/8A

250V

1

GSC-V1/4

1/4A

250V

1

GSC3/10

GSC-3/10

3/10A

250V

1

GSC4/10

GSC-V4/10

4/10A

250V

1

GSC1/2

GSC-V1/2

1/2A

250V

1

GSC6/10

GSC-V6/10

6/10A

250V

1

GSC7/10

GSC-V7/10

7/10A

250V

1

GSC3/4

GSC-V3/4

3/4A

250V

1

GSC8/10

GSC-V8/10

8/10A

250V

1

GSC1

GSC-V1

1A

250V

1

GSC1-1/4

GSC-V1-1/4

1-1/4A

250V

1

GSC1-1/2

GSC-V1-1/2

1-1/2A

250V

1

GSC1-6/10

GSC-V1-6/10

1-6/10A

250V

1

GSC2

GSC-V2

2A

250V

1

GSC2-1/2

GSC-V2-1/2

2-1/2A

250V

1

GSC3

GSC-V3

3A

250V

1

GSC4

GSC-V4

4A

125V

2

GSC5

GSC-V5

5A

125V

2

GSC6

GSC-V6

6A

125V

2

GSC7

GSC-V7

7A

125V

2

GSC8

GSC-V8

8A

125V

2

GSC10

GSC-V10

10A

125V

3

1. 250VAC @ 100A I.R./125VAC @ 10kA I.R.
2. 125VAC @ 10kA I.R.
3. 125VAC @ 1000A I.R.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

C17

Electronic/Glass Fuses

GSB/GSB-V

GDG/GDG-V

Glass body

Ceramic body

••
••
••
••

••
••
••
••

Fast-acting
5mm x 20mm
1-1/2” Axial
leads optional

Fast-acting
5mm x 20 mm
1-1/2” Axial
leads optional

1/16A through 10A, 250VAC, UL and CSA Recognized

1/16A through 10A, 250VAC, UL & CSA Recognized

1/16A through 6-3/10A, 250VAC, SEMKO Approved

1/16A through 6-3/10A, 250VAC, SEMKO Approved

1/16A through 6-3/10A, 250VAC, VDE Approved

1/16A through 6-3/10A, 250VAC, VDE Approved

IEC-127-2 Standard Sheet 2*

IEC 127-2 Standard Sheet 3*

Standard Fuse Ampere Ratings

Standard Fuse Ampere Ratings

1.
2.
3.
4.
5.
6.

Catalog

Axial Lead

Ampere

Number

Cat. No

Rating

Volts

I.R.

Axial Lead

Ampere

Number

Cat. No

Rating

Volts

I.R.

GSB1/16

GSB-V1/16

1/16A

250V

1

GDG1/16

GDG-V1/16

1/16A

250V

1

GSB8/100

GSB-V8/100

8/100A

250V

1

GDG8/100

GDG-V8/100

8/100A

250V

1

GSB1/10

GSB-V1/10

1/10A

250V

1

GDG1/10

GDG-V1/10

1/10A

250V

1

GSB1/8

GSB-V1/8

1/8A

250V

1

GDG1/8

GDG-V1/8

1/8A

250V

1
1

GSB16/100

GSB-V16/100

16/100A

250V

1

GDG16/100

GDG-V16/100

16/100A

250V

GSB2/10

GSB-V2/10

2/10A

250V

1

GDG2/10

GDG-V2/10

2/10A

250V

1

GSB1/4

GSB-V1/4

1/4A

250V

1

GDG1/4

GDG-V1/4

1/4A

250V

1
1

GSB315/1000

GSB-V315/1000

315/1000A

250V

1

GDG315/1000

GDG-V315/1000

315/1000A

250V

GSB4/10

GSB-V4/10

4/10A

250V

1

GDG4/10

GDG-V4/10

4/10A

250V

1

GSB1/2

GSB-V1/2

1/2A

250V

1

GDG1/2

GDG-V1/2

1/2A

250V

1
1

GSB630/1000

GSB-V630/1000

630/1000A

250V

1

GDG630/1000

GDG-V630/1000

630/1000A

250V

GSB8/10

GSB0-V8/10

8/10A

250V

1

GDG8/10

GDG-V8/10

8/10A

250V

1

GSB1

GSB-V1

1A

250V

1

GDG1

GDG-V1

1A

250V

1

GSB1-1/4

GSB-V1-1/4

1-1/4A

250V

1

GDG1-1/4

GDG-V1-1/4

1-1/4A

250V

1

GSB1-6/10

GSB-V1-6/10

1-6/10A

250V

1

GDG1-6/10

GDG-V1-6/10

1-6/10A

250V

1
1

GSB2

GSB-V2

2A

250V

1

GDG2

GDG-V2

2A

250V

GSB2-1/2

GSB-V2-1/2

2-1/2A

250V

1

GDG2-1/2

GDG-V2-1/2

2-1/2A

250V

1

GSB3-15/100

GSB-V3-15/100

3-15/100A

250V

1

GDG3-15/100

GDG-V3-15/100

3-15/100A

250V

1

GSB4

GSB-V4

4A

250V

2

GDG4

GDG-V4

4A

250V

2

GSB5

GSB-V5

5A

250V

3

GDG5

GDG-V5

5A

250V

3

GSB6-3/10

GSB-V6-3/10

6-3/10A

250V

4

GDG6-3/10

GDG-V6-3/10

6-3/10A

250V

4

GSB8

GSB-V8

8A

250V

5

GDG8

GDG-V8

8A

250V

5

GSB10

GSB-V10

10A

250V

6

GDG10

GDG-V10

10A

250V

6

250VAC @ 35A I.R.
250VAC @ 40A I.R.
250VAC @ 50A I.R.
250VAC @ 63A I.R.
250VAC @ 80A I.R.
250VAC @ 100A I.R.

1.
2.
3.
4.
5.
6.

*IEC Standards for 5x20mm fuses do not include ratings above 6.3 amperes.

C18

Catalog

250VAC @ 35A I.R.
250VAC @ 40A I.R.
250VAC @ 50A I.R.
250VAC @ 63A I.R.
250VAC @ 80A I.R.
250VAC @ 100A I.R.

*IEC Standards for 5x20mm fuses do not include ratings above 6.3 amperes.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Electronic/Glass Fuses

••
••
••
••

GSF/GSF-V
••
••
••
••

Ceramic body
Fast-acting
5mm x 20mm
1-1/2” Axial leads optional

Ceramic body

C

GSD/GSD-V

Time-delay
5mm x 20 mm
1-1/2” Axial leads optional

1/16A through 10A, 250VAC, UL & CSA Recognized

1/2A through 8/10A, 250VAC

1A through 6-3/10A, 250 VAC, SEMKO Approved

1A through 6-3/10A, 250VAC, SEMKO, VDE Approved

1A through 6-3/10A, 250 VAC, VDE Approved

1A through 10A, 250VAC, UL and CSA Recognized

IEC 127-2 Standard Sheet 1*

IEC-127-2 Standard Sheet 5*

Standard Fuse Ampere Ratings

Standard Fuse Ampere Ratings

Catalog

Axial Lead Cat.

Ampere

Number

No

Rating

Catalog

Axial Lead

Ampere

Number

Cat. No

Rating

GSD1/16

GSD-V1/16

GSD8/100

GSD-V8/100

1

GSF1/2

GSF-V1/2

1

GSF630/1000

GSF-V630/1000

GSD1/10

250V

1

GSF8/10

1/8A

250V

1

GSD-V16/100

16/100A

250V

GSD-V2/10

2/10A

250V

GSD1/4

GSD-V1/4

1/4A

GSD315/1000

GSD-V315/1000

GSD4/10

Volts

I.R.

Volts

I.R.

1/16A

250V

8/100A

250V

1/2A

250V

1

630/1000A

250V

GSD-V1/10

1/10A

1

GSF-V8/10

8/10A

250V

GSD1/8

GSD-V1/8

1

GSF1

GSF-V1

1A

250V

1

GSD16/100
GSD2/10

1

GSF1-1/4

GSF-V1-1/4

1-1/4A

250V

1

1

GSF1-6/10

GSF-V1-6/10

1-6/10A

250V

1

250V

1

GSF2

GSF-V2

2A

250V

1

315/1000A

250V

1

GSF2-1/2

GSF-V2-1/2

2-1/2A

250V

1

GSD-V4/10

4/10A

250V

1

GSF3-15/100

GSF-V3-15/100

3-15/100A

250V

1

GSD1/2

GSD-V1/2

1/2A

250V

1

GSF4

GSF-V4

4A

250V

1

GSD630/1000

GSD-V630/1000

630/1000A

250V

1

GSF5

GSF-V5

5A

250V

1

GSD8/10

GSD-V8/10

8/10A

250V

1

GSF6-3/10

GSF-V6-3/10

6-3/10A

250V

1

GSD1

GSD-V1

1A

250V

1

GSF8

GSF-V8

8A

250V

1

GSD1-1/4

GSD-V1-1/4

1-1/4A

250V

1

GSF10

GSF-V10

10A

250V

1

GSD1-6/10

GSD-V1-6/10

1-6/10A

250V

1

GSD2

GSD-V2

2A

250V

1

1. 250VAC @ 1500A I.R.

GSD2-1/2

GSD-V2-1/2

2-1/2A

250V

1

*IEC Standards for 5x20mm fuses do not include ratings above 6.3 amperes.

GSD3-15/100

GSD-V3-15/100

3-15/100A

250V

1

GSD4

GSD-V4

4A

250V

1

GSD5

GSD-V5

5A

250V

1

GSD6-3/10

GSD-V6-3/10

6-3/10A

250V

1

GSD8

GSD-V8

8A

250V

1

GSD10

GSD-V10

10A

250V

1

1. 250VAC @ 1500A I.R.
*IEC Standards for 5x20mm fuses do not include ratings above 6.3 amperes.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

C19

Electronic/Glass Fuses

GGX

GAB

•• Glass body
•• Fast-acting
•• 1/4” x 1”

GSR-V

•• Ceramic body
•• Fast-acting
•• 1/4” x 1-1/4”

•• Epoxy-component
Plastic body

•• Fast-acting
•• 7.1mm body length

1/2A through 2 1/2A, 250VAC, UL Listed

1/8A through 20A, 250VAC,

3A through 7A, 125V AC, UL

UL Listed and CSA Certified

1/10A through 15A, 125VAC,

Recognized

25A through 30A, 250VAC

UL Recognized and CSA Certified

Standard Fuse
Ampere Ratings

Standard Fuse
Ampere Ratings

8A through 30A, 32V AC, UL
Recognized

Standard Fuse
Ampere Ratings
Catalog

Ampere

Number

Rating

GGX1/2
GGX3/4

Ampere

Number

Rating

Catalog

Ampere

Number

Rating

1

GAB1/8

1

GAB1/4

1

GSR-V1/10

1

GSR-V1/8

250V

1

1/2A

250V

GAB3/4

3/4A

GAB1

1A

3

GAB2

125V

3

6A

125V

GGX7

7A

GGX8

I.R.

Volts

I.R.

1/2A

250V

3/4A

250V

1/10A

125V

1

1/8A

125V

GGX1

1A

250V

1

1

GSR-V1/4

1/4A

125V

GGX1-1/2

1-1/2A

250V

2

1

1

GSR-V3/8

3/8A

125V

GGX2

2A

250V

2

1

GGX2-1/2

2-1/2A

250V

3

GGX3

3A

125V

3

250V

1

GSR-V1/2

1/2A

125V

1

250V

1

GSR-V3/4

3/4A

125V

GGX4

4A

125V

1

2A

250V

2

GSR-V1

1A

125V

GGX5

5A

1

GAB2-1/2

2-1/2A

250V

2

GSR-V1-1/2

1-1/2A

125V

GGX6

1

3

GAB3

3A

250V

2

GSR-V2

2A

125V

1

125V

3

8A

32V

4

GAB4

4A

250V

3

GSR-V2-1/2

2-1/2A

125V

1

GGX10

10A

32V

4

GAB5

5A

250V

3

GSR-V3

3A

125V

1

GGX12

12A

32V

4

GAB6

6A

250V

3

GSR-V4

4A

125V

1

GGX15

15A

32V

4

GAB7

7A

250V

3

GSR-V5

5A

125V

1

4

GAB8

8A

250V

3

GSR-V7

7A

125V

1

10A

250V

3

GSR-V10

10A

125V

1

GGX20

1.
2.
3.
4.

Catalog

Volts

20A

32V

I.R.

1/8A

250V

1/4A

250V

GAB3/8

3/8A

GAB1/2

GGX25

25A

32V

4

GAB10

GGX30

30A

32V

4

GAB12

12A

250V

4

GSR-V12

12A

125V

1

GAB15

15A

250V

4

GSR-V15

15A

125V

1

GAB20

20A

250V

5

GAB25

25A

250V

6

GAB30

30A

250V

6

250VAC @ 35A I.R./125VAC @ 10kA I.R.
250VAC @ 100A I.R./125VAC @ 10kA I.R.
125VAC @ 10kA I.R.
32VAC

1.
2.
3.
4.
5.
6.

C20

Volts

1. 125VAC @ 50A AC/300A DC I.R.

250VAC @ 35A I.R./125VAC @ 10kA I.R.
250VAC @ 100A I.R./125VAC @ 10kA I.R.
250VAC @ 200A I.R./125VAC @ 10kA I.R.
250VAC @ 750A I.R./125VAC @ 10kA I.R.
250VAC @ 1000A I.R./125VAC @ 10kA I.R.
250VAC @ 400A I.R./125VAC @ 10kA I.R.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Electronic/Glass Fuses

••
••
••
••

STG/STG-V
••
••
••
••

Glass body
Fast-acting
5 x 15mm 2AG
1-1/2” Axial leads optional

Glass body

C

SMG/SMG-V

Time-delay
5 x 15mm 2AG
1-1/2” Axial leads optional

1/10A & 3/8A, 250VAC, UL Listed CSA Certified

3/8A 250VAC, UL Listed and CSA Certified

1/8A through 7A, 350VAC, UL and CSA Recognized

1/4A through 7A, 350VAC, UL and CSA Recognized

8A & 10A, 125VAC

Standard Fuse Ampere Ratings
Catalog

Axial Lead

Ampere

Number

Cat. No

Rating

SMG1/10

SMG-V1/10

SMG1/8

SMG-V1/8

SMG1/4

Standard Fuse Ampere Ratings
Catalog

Axial Lead

Ampere

Number

Cat. No

Rating

1

STG1/4

STG-V1/4

2

STG3/8

STG-V3/8

350V

2

STG1/2

3/8A

250V

1

SMG-V1/2

1/2A

350V

SMG-V3/4

3/4A

350V

SMG1

SMG-V1

1A

SMG1-1/2

SMG-V1-1/2

SMG2

SMG-V2

SMG2-1/2
SMG3

Volts

I.R.

Volts

I.R.

1/10A

250V

1/8A

350V

1/4A

350V

2

3/8A

250V

SMG-V1/4

1/4A

1

STG-V1/2

1/2A

350V

SMG3/8

SMG-V3/8

2

STG6/10

STG-V6/10

6/10A

350V

2

SMG1/2
SMG3/4

2

STG3/4

STG-V3/4

3/4A

350V

2

2

STG8/10

STG-V8/10

8/10A

350V

2

350V

2

STG1

STG-V1

1A

350V

2

1-1/2A

350V

2

STG1-1/4

STG-V1-1/4

1-1/4A

350V

2

2A

350V

2

STG1-1/2

STG-V1-1/2

1-1/2A

350V

2

SMG-V2-1/2

2-1/2A

350V

2

STG2

STG-V2

2A

350V

2

SMG-V3

3A

350V

2

STG2-1/2

STG-V2-1/2

2-1/2A

350V

2

SMG3-1/2

SMG-V3-1/2

3-1/2A

350V

2

STG3

STG-V3

3A

350V

2

SMG4

SMG-V4

4A

350V

2

STG3-1/2

STG-V3-1/2

3-1/2A

350V

2

SMG5

SMG-V5

5A

350V

2

STG4

STG-V4

4A

350V

2

SMG6

SMG-V6

6A

350V

2

STG5

STG-V5

5A

350V

2

SMG7

SMG-V7

7A

350V

2

STG6

STG-V6

6A

350V

2

SMG8

SMG-V8

8A

125V

3

STG7

STG-V7

7A

350V

2

SMG10

SMG-V10

10A

125V

3

1. 250VAC @ 35A I.R./125VAC @ 10kA I.R.
2. 350VAC @ 100A I.R./140VDC @ 150A I.R.
3. 125VAC @ 10kA I.R.

1. 250VAC @ 35A I.R./125VAC @ 10kA I.R.
2. 350VAC @ 100A I.R./125VAC @ 10kA I.R.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

C21

Radial Lead Micro Fuses

MRF

MRT

Thermoplastic body

Thermosplastic body

and cap, UL 94-V0

and cap, UL 94-V0

Pins are tin-lead plated copper alloy

Pins are tin-lead plated copper alloy

Approvals: SEMKO, VDE, MITI, CE UL Recognized,

Approvals: SEMKO, VDE, MITI, CE UL Recognized,

CSA Accepted

CSA Accepted

50mA to 6.3A, 250VAC - UL Recognized and CSA Accepted

80mA to 6.3A, 250VAC - UL Recognized and CSA Accepted

Standard Fuse Ampere Ratings

Standard Fuse Ampere Ratings

•• Fast-acting microfuse

Catalog

Ampere

Number

Rating

MRF50

50mA

MRF63

•• Time-delay microfuse

Fuse

Catalog

Ampere

Length

Number

Rating

250V

1

MRT80

80mA

250V

1

63mA

250V

1

MRT100

100mA

250V

1

MRF80

80mA

250V

1

MRT125

125mA

250V

1

MRF100

100mA

250V

1

MRT160

160mA

250V

1

MRF125

125mA

250V

1

MRT200

200mA

250V

1

MRF160

160mA

250V

1

MRT250

250mA

250V

1

MRF200

200mA

250V

1

MRT315

315mA

250V

1

MRF250

250mA

250V

1

MRT400

400mA

250V

1

MRF315

315mA

250V

1

MRT500

500mA

250V

1

MRF400

400mA

250V

1

MRT630

630mA

250V

1

MRF500

500mA

250V

1

MRT800

800mA

250V

1

MRF630

630mA

250V

1

MRT1

1A

250V

1

MRF800

800mA

250V

1

MRT1.25

1.25A

250V

1

MRF1

1A

250V

1

MRT1.6

1.6A

250V

1

MRF1.25

1.25A

250V

1

MRT2

2A

250V

1

MRF1.6

1.6A

250V

1

MRT2.5

2.5A

250V

1

MRF2

2A

250V

1

MRT3.15

3.15A

250V

1

MRF2.5

2.5A

250V

1

MRT4

4A

250V

1

MRF3.15

3.15A

250V

1

MRT5

5A

250V

1

MRF4

4A

250V

1

MRT6.3

6.3A

250V

1

MRF5

5A

250V

1

MRF6.3

6.3A

250V

1

Volts

Volts

Fuse
Length

1. 250VAC @ 50A I.R.

1. 250VAC @ 50A I.R.

C22

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

In-Line Fuse Holders SFRT, SFRB, SFRG, FSFE, SFRU

•• Twist-lock
•• In-line fuse holders
for FSFE fuses.

•• Used at 32V or less with fuses
rated up to 20A when proper spring

SFRB

•• Bayonet knob
•• In-line fuse holders

C

SFRT

for FSFE fuses.

•• Used at 32V or less with fuses rated up to 20A
when proper spring for fuse size is installed.

for fuse size is installed.

Standard Fuse Ampere Ratings

Standard Fuse Ampere Ratings

Catalog

Fuse

Catalog

Fuse

Number*

Installed

Number*

Installed

SFRT4

FSFE4

SFRB4

FSFE4

SFRT6

FSFE6

SFRB6

FSFE6

SFRT7-1/2

FSFE7-1/2

SFRB7-1/2

FSFE7-1/2

SFRT9

FSFE9

SFRB9

FSFE9

SFRT14

FSFE14

SFRB14

FSFE14

SFRT20

FSFE20

SFRB20

FSFE20

*Includes FSFE fuse

*Includes FSFE fuse

FSFE

•• Glass body
•• Fast-acting

SFRG

•• In-line fuse holder
for 5 x 20mm fuses.

4A through 30A, 32VAC/DC - UL Listed

•• Max. current rating for
5x20mm fuses - 10A @ 32V

Standard Fuse Ampere Ratings

SFRU
Universal in-line fuse holder supplied with 15” loop of #14 AWG
red vinyl insulated wire frame and

Catalog

Ampere

Number

Rating

FSFE4

4A

Volts
32V

Fuse
Length
5/8”

FSFE6

6A

32V

3/4”

FSFE7-1/2

7-1/2A

32V

7/8”

FSFE9

9A

32V

7/8”

FSFE14

14A

32V

1-1/16”

FSFE20

20A

32V

1-1/4”

FSFE30

30A

32V

1-7/16”

three springs in different lengths to
accomodate FSFE size fuses.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

C23

In-Line Fuses and Holders SLR, SMF, SHR
Mersen SLR and SMF in-line fuses are used to protect fluorescent lighting fixtures
and ballasts. The SLR is a fast-acting fuse. SMF is a time-delay fuse. Both used to
protect individual 300V fixtures. Mersen’s SHR fuse holder has an integral clip for
panel mounting to meet this requirement. The holder fits into a standard 7/8” knockout or keyhole punch that provides anti-rotation. The SHR is available in a single or
double wire version. The single wire version (SHR-1) allows insertion of #18 AWG
ballast leads directly into the holder.

SLR Fuses
Ratings:

SMF Fuses
Ratings:

SHR Fuse Holders
Ratings:

Volts	

: 300VAC

Volts	

: 300VAC

Volts	

	

: 125VAC

	

: 125 VAC

Amps	 : 15A

: 300VAC

Amps	 : 1/2 to 15A

Amps	 : 3/10 to 10A

Withstand Rating:

I.R.	

: 100kA I.R.

I.R.	

: 100kA I.R.

	

	

: 10kA I.R.

	

: 10kA I.R.

Dielectric Strength:
	

Approvals:
•• UL Listed

Approvals:
•• UL Listed	

: 10kA I.R.
: 2,000V

Approvals:

•• UL Recognized

File No. E10480

File No. E10480

Component Guide

CSA Certified

CSA Certified

IZLT2, UL File
No. E52283

Highlights:

•• Fast-acting
•• Integral fuse &
insulating cap

Highlights:

•• Time-delay
•• Integral fuse &

Highlights:

•• Superior wire
retention

insulating cap

•• Thermoplastic

to handle ballast

•• Single and two

•• Designed specifically
inrush currents

insulator - 150º C RTI
wire versions

•• Two load plug-in
ports available

•• Integral mounting clip
0.062” thick panel

•• Integral wire retention
clip to hold #18 wire

•• Tin plated, insulated
#18 solid copper wire
leads, 6” length

C24

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

In-Line Fuses and Holders SLR, SMF, SHR
Catalog Numbers
Rating

Catalog Numbers

300mA
500mA

SMF3/10
SLR1/2

SMF1/2

600mA
1A

SMF1-1/4
SLR1-1/2

1-6/10A

SLR1-6/10

SMF1-6/10

SLR2

SMF2

2-1/2A

SLR2-1/2

SMF2-1/2

SLR3

SMF3

2-8/10A

.26

7.0
mm

.25

SMF2-8/10

3-2/10A

(6.35 mm)

.5

SMF3-2/10

4A

SLR4

SMF4

5A

SLR5

SMF5

6A

SLR6

6 1/4A
7A

SHR

S MF1

2A

3A

SHR-1

SMF8/10
SLR1

1-1/4A
1-1/2A

Two Wire

Note: Both holders are compatible
with all fluorescent light fuses

SMF6/10

800mA

Single Wire

C

Ampere

Fuse Holders

(12.8 mm)

1.9

(48 mm)

SMF 6 1/4
SLR7

SMF7
SMF8

8A

SLR8

9A

SLR9

10A

SLR10

12A

SLR12

15A

SLR15

LOAD WIRE
(BLACK)

.5

SMF10

STRIPPED
WIRE
LENGTH

.13

.5

STRIPPED
WIRE
LENGTH

LINE WIRE
(RED)

2.32

6

.51

.28

.670
GRIPS ONTO
.18 AWG WIRE

.202

0 .875

Note: SHR-1, LINE WIRE ONLY

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

C25

Automotive Fuses AF, AF2, AF3

AF

AF2

•• Automotive fuse
•• Fast-acting

•• Automotive fuse
•• Fast-acting
•• Plastic body/silver-plated

1A through 40A, 32VAC/DC

terminals

1000 A I.R.
2A through 30A, 32VDC
1000 A I.R.

Standard Fuse Ampere Ratings
Catalog Number

Ampere Rating

Volts

Body Color

AF-1

1A

32V

BLACK

AF-2

2A

32V

GREY

Catalog Number

Ampere Rating

Volts

Body Color

AF-3

3A

32V

VIOLET

AF2-2

2A

32V

GREY

AF-4

4A

32V

PINK

AF2-3

3A

32V

VIOLET

AF-5

5A

32V

TAN

AF2-4

4A

32V

PINK

AF-7-1/2

7-1/2A

32V

BROWN

AF2-5

5A

32V

TAN

AF-10

10A

32V

RED

AF2-7-1/2

7-1/2A

32V

BROWN

AF-15

15A

32V

BLUE

AF2-10

10A

32V

RED

AF-20

20A

32V

YELLOW

AF2-15

15A

32V

BLUE

AF-25

25A

32V

NATURAL

AF2-20

20A

32V

YELLOW

AF-30

30A

32V

GREEN

AF2-25

25A

32V

NATURAL

AF-35

35A

32V

BLUE GREEN

AF2-30

30A

32V

GREEN

AF-40

40A

32V

AMBER

AF3

•• Automotive fuse
•• Time-delay
•• Plastic body/silver-plated terminals

20A through 80A, 32VDC, 1000 A I.R.

C26

Standard Fuse Ampere Ratings

Standard Fuse Ampere Ratings
Catalog Number

Ampere Rating

Volts

Body Color

AF3-20

20A

32V

YELLOW

AF3-30

30A

32V

GREEN

AF3-40

40A

32V

AMBER

AF3-50

50A

32V

RED

AF3-60

60A

32V

BLUE

AF3-70

70A

32V

TAN

AF3-80

80A

32V

NATURAL

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Automotive Fuse Holders AFH20, AFH30
In-line fuseholders for blade type automobile fuses. 4” stranded wire leads

Catalog Number

Fuse Type & Max Amp

Volts

Body Color

AWG/Color

AFH20-14

AF Fuse/20A

32V

BLACK

#14/BLACK

AFH20-14Y

AF Fuse/20A

32V

YELLOW

#14/BLACK

AFH20-16

AF Fuse/20A

32V

YELLOW

#16/BLACK

AFH20-16Y

AF Fuse/20A

32V

YELLOW

#16/BLACK

Catalog Number

Fuse Type & Max Amp

Volts

Body Color

AWG/Color

AFH30-12

AF Fuse/30A

32V

BLACK

#12/YELLOW

AFH30C

AF Fuse/30A

32V

BLACK

#12/ORANGE

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

C

are stripped back 1/4”.

www.barr-thorp.com

C27

Automotive Fuse Holders

C28

Catalog Number

Fuse Type & Max Amp

Volts

Body Color

AWG/Color

AF2H30C

AF Fuse/30A

32V

BLACK

#12/ORANGE

Catalog Number

Fuse Type & Max Amp

Volts

Body Color

AWG/Color

AF3H60C

AF Fuse/60A

32V

BLACK

#6/RED

AF2H30, AF3H60

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Semiconductor Fuses
Semiconductor technology is widespread. Not by coincidence, so’s our semiconductor fuse line.

Your problem:

D

powered product
exists today that

Semiconductor Fuses

• Amp-Trap® Form 101 / A15QS.......... D2

doesn’t rely on
semiconductor

• Amp-Trap® Form 101 / A30QS......... D4

technology to

• Amp-Trap® Form 101 / A50QS......... D6

some degree. That

• Amp-Trap® Form 101 / A50P............. D8

means extending

• Amp-Trap® Form 101 / A60Q........... D10

circuit protection
to thyristors, triacs, diodes, and a host of other solid-state

• Amp-Trap® Form 101 / A60X........... D11

components — as well as a wide range of voltage requirements,

• Protistor® / A070gRB....................... D13

unique mounting configurations, and special protection
characteristics.

• French Cylindrical / A70QS............. D14
• Amp-Trap® Form 101 / A70QS........ D16

Our solution: Mersen affords OEM designers and equipmentmaintenance personnel a comprehensive line of Form 101
semiconductor protection fuses in ratings from 130 to 1500VAC.
Plus, Square Body North American and European-Dimension

• Amp-Trap® Form 101 / A70P........... D18
• Amp-Trap® Form 101 / A70Q........... D20
• Amp-Trap® Form 101 / A100P......... D22

semiconductor fuses in 690/700 and 1250/ 1300V ratings (four

• Amp-Trap® Form 101 / A120X......... D24

sizes of each). Plus, compatible fuse blocks and acccessories

• Amp-Trap® Form 101 / A150X......... D25

such as blown-fuse indicatiors, Trigger switch actuators, and
®

add-on switches.
Want more information fast? For more technical or
application-specific information, please call our Semiconductor
Fuse experts, at 978-462-6662; 416-252-9371 in Canada; or visit
our website at us-ferrazshawmut.mersen.com.

• DIN 6,9gRB-URB;6,6gRB-URB...... D26
• British Standard............................... D31
• PSC Square Body 690/700V........... D44
• PSC Square Body 1250/1300V....... D55
• French Cylindrical........................... D63

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D

Hardly an electric-

A15QS Semiconductor Protection Fuses
A15QS Amp-Trap® Form 101 Semiconductor Protection fuses were designed for the
specific protection of diodes and other semiconductor devices rated 150VAC/DC.
The A15QS product line’s compact design is perfect for those applications that have
limitations on available space.

Features/Benefits:
•• Low I2t minimizes damage to protected components on short circuit
•• Controlled arc voltage reduces stress to circuit components during fuse clearing
•• Choice of mounting types provides options for unique termination requirements

Highlights:

Applications:

•• Fast acting

•• Protection of heavy duty devices

•• Current limiting

such as electrochemical rectifiers

•• Low I2t

Ratings:

•• Indicator options available

Volts	

: 150VAC / DC

Amps	 : 1 to 6000A

Catalog Numbering System
		

A

			

15 QS

400 - 4

I.R.	

: 100kA I.R. AC

	

: 100kA I.R. DC

TI

Amp-Trap® Fuse				
A
	
Rated Volts - 150		
	

15

Style

QS

Amperes*		400
Mounting Types*	
Ferrule			

1

Ferrule, midget dims.		
2
(1-1/2” x 13/32”)
Blades, bolt-in	

4
128
Hockey puck, bolt-in		
Integral Blown-Fuse
Indicator

TI
IL

Trigger Indicator (see pg. J5)		
IL Indicator (see pg. J6)		

Single Pole Fuse
Blocks for
A15QS Fuses
Fuse
Ampere
Rating

Approvals:
•• UL recognized component UL
File E60314
•• AC: UL guide no. JFHR2

Catalog
No.

1-30

30311

31-60

U71006

500-600

P243G

40-450

P243D

800

ISC375

(1-4000A)
•• DC tested to UL standard 198L
parameters (1-4000A)

* For ampere ratings and types not listed, consult the factory.
** For harsh duty appllications, refer to the A13X product family.
Consult the factory or A13X application information.

D2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A15QS Semiconductor Protection Fuses
Catalog Numbers (amps)
Dimen. Fig.

Catalog No.

Dimen. Fig.

Catalog No.

Dimen. Fig.

Catalog No.

A15QS1-2

1

A15QS70-4

2

A15QS350-4TI

2

A15QS2000128IL

5

A15QS2-2

1

A15QS70-4TI

2

A15QS400-4

2

A15QS2500-128

4

A15QS3-2

1

A15QS80-4

2

A15QS400-4IL

3

A15QS2500-128IL

5

A15QS4-2

1

A15QS80-4TI

2

A15QS400-4TI

2

A15QS3000-128

4

A15QS5-2

1

A15QS90-4

2

A15QS450-4

2

A15QS3000-128IL

5

A15QS6-2

1

A15QS100-4

2

A15QS450-4IL

3

A15QS3500-128

6

A15QS7-2

1

A15QS100-4TI

2

A15QS500-4

2

A15QS4000-128

6

A15QS8-2

1

A15QS130-4

2

A15QS500-4IL

3

A15QS4000-128IL

7

A15QS10-2

1

A15QS130-4TI

2

A15QS600-4

2

A15QS4500-128

8

A15QS12-2

1

A15QS150-4

2

A15QS600-4IL

3

A15QS4500-128IL

A15QS15-2

1

A15QS150-4IL

3

A15QS800-4

2

A15QS5000-128

8

A15QS20-2

1

A15QS150-4TI

2

A15QS1000-4

2

A15QS6000-128

8

A15QS25-2

1

A15QS175-4TI

2

A15QS1000-4IL

3

A15QS30-2

1

A15QS200-4

2

A15QS1000-4TI

2

A15QS35-1

1

A15QS200-4IL

3

A15QS1000-128

4

A15QS40-1

1

A15QS250-4

2

A15QS1000-128IL

5

A15QS404TI

2

A15QS250-4TI

2

A15QS1200-128

4

A15QS45-1

1

A15QS300-4

2

A15QS1200-128IL

5

A15QS50-1

1

A15QS300-4TI

2

A15QS1500-128

4

A15QS50-4

2

A15QS300-4IL

3

A15QS1500-128IL

5

A15QS60-1

1

A15QS350-4

2

A15QS2000-128

4

Dimen. Fig.

D

Catalog No.

* For ampere ratings and styles not listed, call Technical Services at 978-465-4853.

Dimensions
Outline Ref.

Mounting Type

Fig.

A15QS1 to 30

2

1

15QS35 to 60

1

1

A15QS20 to 450

4, 4TI*, 4IL*

2, 3*

A15QS500 to 1000
A15QS750 to 2000
A15QS2500 to 3000
A15QS3500 to 4000
A15QS4500 to 6000

4, 4TI*, 4IL*
128, 128IL*
128, 128IL*
128, 128IL*
128

2, 3*
4, 5*
4, 5*
6, 7*
8

Dimensions - Inches (mm)

Tap

A

B

C

D

E

F

G

H

.50

.41

-

-

-

-

-

-

(38.1)

(10.4)

-

-

-

-

-

-

-

2.00

.81

-

-

-

-

-

-

-

-

(50.8)

(20.6)

-

-

-

-

-

-

-

2.66

1.13

1.16

2.19

1.91

.31

.74

.13

-

(67.6)

(28.7)

(29.5)

(55.6)

(48.5)

(7.9)

(22.4)

(4.8)

-

3.50

1.50

1.25

2.56

1.94

.41

1.00

.25

-

(88.9)

(38.1)

(31.8)

(65.0)

(49.3)

(10.4)

(25.4)

(6.4)

-

1.88

2.00

1.63

1.75

1.00

-

-

-

3/8-24-1/2 Deep

(47.8)

(50.8)

(41.4)

(44.5)

(25.4)

-

-

-

-

1.88

3.00

1.63

2.50

1.50

-

-

-

1/2-20-1/2 Deep

(47.88)

(76.2)

(41.4)

(63.5)

(38.1)

-

-

-

-

1.88

3.50

1.63

3.00

1.06

1.06

-

-

1/2-20-1/2 Deep

(47.88)

(88.9)

(41.4)

(76.2)

(27.0)

(27.0)

-

-

-

2.38

5.75

1.88

5.00

1.50

1.50

-

-

1/2-20-1/2 Deep

(60.5)

(146)

(47.7)

(127)

(38.1)

(38.1)

-

-

-

* Optional Trigger Indictator (TI) and (IL) indicator.

Figure 1

Figure 4

Figure 3

Figure 2

Figure 5

Figure 6

Figure 7

Figure 8

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D3

A30QS Semiconductor Protection Fuses
A30QS Amp-Trap® Semiconductor Protection fuses are intended for the protection
of Power Semiconductors such as diodes, phase control SCR’s and other power
semiconductor devices. The A30QS is recommended for new applications providing
solutions for your critical protection needs at 300V and less semiconductors.

Features/Benefits:
•• Low I2t minimizes damage to protected component on short circuit
•• Controlled arc voltage reduces stress to circuit components during
fuse clearing
•• Choice of mounting types helps in equipment design

Highlights:

Applications:

•• Fast acting

•• Protection of 300V (or less) heavy

•• Current-limiting

duty rectifiers and similar heavy duty

•• Low I t

power supplies

2

Volts	

•• Indicator options available

: 300VAC / DC

Amps	 : 1 to 4500A

•• Superior DC capabilities

Catalog Numbering System
		

A

			

Ratings:

30 QS

600 - 4

I.R.	

: 200kA I.R. AC

	

: 100kA I.R. DC

L/R 	

: 10ms

TI

Amp-Trap® Fuse				
A
	
Rated Volts - 25		
	

30

Style

QS

Amperes*		600
Mounting Types*	
Ferrule			
1
Blades, bolt-in	
4
Hockey puck, bolt-in		
128

Single Pole Fuse
Blocks for
A30QS Fuses

•• UL recognized component
UL File E60314
•• AC: UL guide no. JFHR2

Fuse
Ampere

Approvals:

Catalog No.

(35-4500A)

Rating

Integral Blown-Fuse
Indicator

TI
IL

Trigger Indicator (see pg. J5)		
IL Indicator (see pg. J6)		
* For ampere ratings and styles not listed, call Technical Services at
978-465-4853.

D4

1-30

70316 + US14

31-60

P243G

61-100

P243

101-200

P243

401-600

P243G

700-800

ISC375

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A30QS Semiconductor Protection Fuses
Catalog Numbers (amps)
Dimen. Fig.

Catalog No.

Dimen. Fig.

Catalog No.

Dimen. Fig.

A30QS1-1
A30QS2-1
A30QS3-1
A30QS4-1
A30QS5-1
A30QS6-1
A30QS7-1
A30QS8-1
A30QS10-1
A30QS12-1
A30QS15-1
A30QS20-1
A30QS25-1
A30QS30-1
A30QS35-4
A30QS40-4
A30QS50-4
A30QS60-4
A30QS70-4
A30QS80-4
A30QS90-4
A30QS100-4

1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
3
3
3
3

A30QS100-4TI
A30QS125-4
A30QS130-4
A30QS150-4
A30QS150-4TI
A30QS175-4
A30QS200-4
A30QS200-4TI
A30QS225-4
A30QS250-4
A30QS250-4TI
A30QS300-4

3
3
3
3
3
3
3
3
3
3
3
3

A30QS300-4TI
A30QS350-4
A30QS400-4
A30QS400-4IL
A30QS400-4TI
A30QS450-4
A30QS500-4
A30QS550-4
A30QS600-4

3
3
3
4
3
3
3
3
3

A30QS600-4TI
A30QS600-4IL
A30QS700-4
A30QS700-128
A30QS800-4
A30QS800-4IL
A30QS800-128
A30QS1000-128
A30QS1000-128IL
A30QS1200-128
A30QS1500-128
A30QS1500-128IL
A30QS1600-128
A30QS2000-128
A30QS2000-128IL
A30QS2500-128
A30QS2500-128IL
A30QS3000-128
A30QS3500-128
A30QS3500-128IL
A30QS4000-128
A30QS4500-128

3
4
4
5
3
4
5
5
5
5
6
7
6
6
7
6
7
6
6
7
6
6

D

Catalog No.

* For ampere ratings and styles not listed, call Technical Services at 978-465-4853.

Dimensions
Outline Ref.

Mounting Type

Fig.

A30QS1 to 30

1

1

A30QS35 to 60

4

2

A30QS70 to 200

4

3

A30QS225 to 700

4, 4IL*

3,4*

A30QS700 to 1200

128

5

A30QS1500 to 2500
A30QS3000 to 4500
A30QS3000 to 4500

128, 128IL*
128, 128IL*
128, 128IL*

6, 7*
6, 7*
6, 7*

Dimensions - Inches (mm)
A

B

C

D

E

F

G

H

2.00

0.56

(51)

(14)

-

-

-

-

-

-

3.19
(81)

.081

1.63

2.50

2.25

0.34

.72

0.13

(21)

(41)

(64)

(58)

(9)

(18)

(3)

3.13

1.22

1.63

2.44

2.19

0.31

1.22

0.19

(80)

(31)

(41)

(62)

(55)

(8)

(31)

(5)

3.84

1.50

1.59

3.10

2.28

0.41

1.00

0.25

(98)

(38)

(40)

(74)

(58)

(10)

(25)

(6)

2.59

3.00

2.34

2.50

1.50

(66)

(76)

(59)

(64)

(38)

-

-

-

2.59

3.50

2.34

3.00

1.50

1.50

(66)

(76)

(59)

(64)

(38)

-

2.59

4.50

2.34

3.75

1.50

1.50

2.59

4.50

2.34

3.75

1.50

1.50

(66)

(114)

(59)

(95)

(38)

(38)

-

-

Tap
3/8-24-1/2 Deep
(2)
3/8-24-1/2 Deep
(4)

* Optional (IL) Indicator
-

-

1/2-20-1/2 Deep
(4)

1/2-20-1/2 Deep
(4)

* Optional (IL) indicator.

Figure 1

Figure 2

Figure 4

Figure 5

Figure 3

Figure 6

Figure 7

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D5

A50QS Semiconductor Protection Fuses
A50QS Amp-Trap® Form 101 fuses grew out of the need to improve the overall
performance of semiconductor fuses in response to new equipment requirements.
The A50QS encompasses the best protection features – lower I2t to provide better
protection for equipment, longer life when subjected to cyclic loading and lower
watts loss. A50QS is today’s best choice for the protection of dynamic solid state
equipment such as motor drives, inverters, UPS, etc.

Features/Benefits:
•• Lowest I2t for greatest protection of semiconductor circuits
•• Low watts loss for cooler operation
•• Superior cycling ability gives an equipment design advantage
•• State-of-the-art protection for 500V equipment
•• Ultra compact sizes allow down-sizing of existing equipment

Highlights:

Applications:

Ratings:

•• 500V AC/DC rated

•• Protection of 500V or less motor

Volts	

•• Lowest I2t

drives, UPS, inverters, etc.

: 500VAC / DC

Amps	 : 35 to 60A (AC)

•• Low watts loss

	

: 70 to 1200A (AC)

•• Superior cycling ability

	

: 35 to 1200A (DC)

I.R.	

: 200kA I.R. AC

	

: 100kA I.R. DC

Catalog Numbering System
		

A

			

50 QS

250 - 4

Amp-Trap® Fuse				
A
	
Rated Volts - 500		
	

50

Style

QS

Amperes*		250
Mounting Types*	
Blades, bolt-in	

4

* For ampere ratings and styles not listed, call Technical Services at
978-465-4853.

Single Pole Fuse Blocks
for A50QS Fuses
Fuse
Ampere
Rating

Mounting
Type

Approvals:
•• UL recognized component
UL File 60314
•• AC: UL guide no. JFHR2
•• DC Tested to UL standard
198L parameters (701200A)
•• CSA Certified LR12636

Catalog No.

35-200

4

P243E

225-600

4

P266C

700-800

4

1SC375

900-1200

4

FH5OF5*

*(not UL)

D6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A50QS Semiconductor Protection Fuses
Catalog Numbers (amps)
A50QS250-4

A50QS40-4

A50QS300-4

A50QS50-4

A50QS350-4

A50QS60-4

A50QS400-4

A50QS70-4

A50QS450-4

A50QS80-4

A50QS500-4

A50QS90-4

A50QS600-4

A50QS100-4

A50QS700-4

A50QS125-4

A50QS800-4

A50QS150-4

A50QS900-4

A50QS175-4

A50QS1000-4

A50QS200-4

A50QS1200-4

D

A50QS35-4

A50QS225-4
* For ampere ratings and styles not listed, call
Technical Services at 978-465-4853.

Dimensions
Catalog Number
A50QS35 to 100
A50QS125 to 200
A50QS225 to 400
A50QS450 to 600
A50QS700 to 800
A50QS900 to 1200

Dimensions - Inches (mm)

Mounting
Type
4
4
4
4
4
4

A

B

C

D

E

F

G

H

3.63

1.00

2.13

2.94

2.75

0.31

0.75

0.13

(92.2)

(25.4)

(54.1)

(74.7)

(69.9)

(7.9)

(19.1)

(3.3)

3.63

1.22

2.13

2.94

2.81

0.31

1.00

0.19

(92.2)

(31.0)

(54.1)

(74.7)

(71.4)

(7.9)

(25.4)

(4.8)

4.34

1.50

2.09

3.41

2.78

0.41

1.00

0.25

(110)

(38.1)

(53.1)

(86.6)

(70.6)

(10.4)

(25.4)

(6.4)

4.47

2.00

2.22

3.53

2.91

0.41

1.50

0.25

(114)

(50.8)

(56.4)

(89.7)

(73.9)

(10.4)

(38.1)

(6.4)

6.47

2.38

2.22

5.00

3.44

.53

2.00

.38

(164.3)

(60.3)

(56.4)

(127.0)

(87.3)

(13.5)

(50.8)

(9.8)

6.97

2.88

3.22

5.47

4.47

.63

2.38

.44

(177.0)

(76.2)

(81.8)

(138.9)

(113.5)

(15.9)

(60.3)

(11.1)

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D7

A50P Semiconductor Protection Fuses
A50P Amp-Trap® Form 101 Semiconductor Protection fuses were developed
for DC drives, uninterruptable power supplies and similar applications requiring
better protection (lower I2t) and superior reliability. The A50P is typically used for
replacement.

Features/Benefits:
•• Low I2t minimizes damage to protected components on short circuit
•• Controlled arc voltage reduces stress to circuit components during fuse clearing
•• Choice of mounting types helps in equipment design

Highlights:

Applications:

•• Very fast acting

•• Protection of DC drives, UPS and

•• Current limiting

other equipment of 500 volts

•• Low I2t

or less

•• Indicator options available

Ratings:

Catalog Numbering System
		

A

			

50

P

100 - 4

TI

Volts	

: 500VAC

	

: 450VDC

Amps	 : 10 to 1200A (AC)

Amp-Trap® Fuse				
A
	

	

: 35 to 1000A (DC)

I.R.	

: 100kA I.R. AC

Rated Volts - 500		
	

50

	

: 79kA I.R. DC

P

: 10ms

Style

L/R	

Amperes*		100
Mounting Types*	
1
4
Blades, bolt-in			
Ferrule		

Integral Blown-Fuse
Indicator

* Contact technical services
for applications data.

TI
TA

Approvals:
•• UL Recognized Component
UL File 60314
•• AC: UL Guide No. JFHR2

Trigger Indicator (see pg. J5)		
Trigger Actuator (see pg. J5)		

(10-800A)

* For ampere ratings and styles not listed, call Technical Services at
978-465-4853.

•• DC: UL Guide No.JFHR2
(35-800A)

Single Pole Fuse Blocks for A50P Fuses

D8

Fuse Ampere

Mounting

Fuse Block

Rating

Type

Catalog No.

10-30

1

70316

35-60

4

P243G

70-200

4

P243E

225-600

4

P266C

700-800

4

1SC375

900-1000

4

FH50F5*

*(not UL)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A50P Semiconductor Protection Fuses
Catalog Numbers (amps)
Dimen. Fig.

Catalog No.

Dimen. Fig.

Catalog No.

Dimen. Fig.

A50P10-1
A50P15-1
A50P20-1
A50P25-1
A50P30--1
A50P35-4
A50P40-4
A50P50-4
A50P60-4
A50P70-4
A50P80-4
A50P90-4
A50P100-4
A50P100-4TI
A50P125-4
A50P125-4TA
A50P125-4TI
A50P150-4
A50P150-4TI

1
1
1
1
1
2
2
2
2
3
3
3
3
3
3
4
3
3
3

A50P175-4
A50P175-4TI
A50P200-4
A50P200-4TA
A50P200-4TI
A50P225-4
A50P250-4
A50P250-4TA
A50P250-4TI
A50P275-4
A50P300-4
A50P300-4TA
A50P300-4TI
A50P325-4
A50P350-4
A50P350-4TI
A50P400-4
A50P400-4TA
A50P400-4TI

3
3
3
4
3
3
3
4
3
3
3
4
3
3
3
3
3
4
3

A50P450-4
A50P450-4TI
A50P500-4
A50P500-4TI
A50P600-4
A50P600-4TA
A50P600-4TI
A50P700-4
A50P700-4TA
A50P700-4TI
A50P800-4
A50P800-4TA
A50P800-4TI
A50P900-4
A50P1000-4
A50P1000-4TI
A50P1200-4
A50P1200-4TI

3
3
3
3
3
4
3
5
6
5
5
6
5
3
3
3
3
3

D

Catalog No.

* For ampere ratings and styles not listed, call Technical Services at 978-465-4853.

Dimensions
Outline

Mounting

Ref.

Type

A50P10 to 30

1

A50P35 to 60
A50P35 to 60
A50P70 to 100
A50P125 to 200

Fig.
1

1DS*

1

4

2

4

3

4, 4TA**

3, 4**

A50P225 to 400

4, 4TA**

3, 4**

A50P450 to 600

4, 4TA**

3, 4**

A50P700 to 800

4, 4TA**

5, 6**

A50P900 to 1200

4

3

Figure 1

Dimensions - Inches (mm)
A

B

C

D

E

F

G

H

2.00

0.56

-

-

-

-

-

-

(50.8)

(14.2)

-

-

-

-

-

-

2.25

0.81

-

-

-

-

-

-

(57.2)

(20.6)

-

-

-

-

-

-

3.19

0.81

1.63

2.50

2.25

0.34

0.72

0.13

(81.0)

(20.6)

(41.4)

(63.5)

(57.2)

8.6)

(18.3)

(3.3)

3.63

1.00

2.13

2.94

2.81

0.31

0.75

0.13

(92.2)

(25.4)

(54.1)

(74.7)

(71.4)

(7.9)

(19.1)

(3.3)

3.63

1.22

2.13

2.94

2.81

0.31

1.00

0.19

(92.2)

(31.0)

(54.1)

(74.7)

(71.4)

(7.9)

(25.4)

(4.8)

4.34

1.50

2.09

3.41

2.78

0.41

1.00

0.25

(110)

(38.1)

(53.1)

(86.6)

(70.6)

(10.4)

(25.4)

(6.4)

4.47

2.00

2.22

3.53

2.91

0.41

1.50

0.25

(114)

(50.8)

(56.4)

(89.7)

(73.9)

(10.4)

(38.1)

(6.4)

6.47

2.50

2.22

4.63

4.31

0.53

2.00

0.38

(164)

(63.5)

(56.4)

(118)

(109)

(13.5)

(50.8)

(9.7)

6.97

3.00

3.22

4.97

***

0.63

2.38

0.44

(177)

(76.2)

(81.8)

(126)

***

(16.0)

(60.5)

(11.1)

Figure 3

Figure 2

	 *	 Use with 60306J fuse block.
	 ** 	 Optional Trigger Actuator (TA)
	*** 	 Mounting hole is round,
		 diameter F.

Figure 4

Figure 5

Figure 6

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D9

A60Q Semiconductor Protection Fuses
A60Q Amp-Trap® Form 101 Semiconductor Protection fuses feature the only 600V
AC / DC rating in the industry of similar size (1-1/2” x 13/32”) fuses protecting
semiconductors. A60Q also has the lowest l2t of all similar fuses and excellent
cycling ability. Applications include inverters and small equipment requiring extremely
fast response to faults, without the need to carry sustained heavy overloads.

Features/Benefits:
•• Lowest I2t of any fuse this size for greater protection
•• Excellent cycling ability gives advantage in equipment design
•• 600V AC / DC rated

Highlights:

Applications:

•• 600VAC/DC rated

•• Protection of small inverters and

•• Extremely fast acting

drives, and equipment requiring

•• Current limiting

the highest degree of protection

•• Lowest I2t

Volts	

•• Excellent cycling ability

		

A

60

Q

30 - 2

Amp-Trap® Fuse				
A
	
Rated Volts - 600		
	

60

Style

Q

Amperes*		30
Mounting Type	
Ferrule, midget dims.
(1-1/2” x 13/32”)

: 600VAC / DC

Amps	 : 5 to 40A (AC)

Catalog Numbering System
			

Ratings:
	

: 5 to 40A (DC)

I.R.	

: 200kA I.R. AC

	

: 100kA I.R. DC

L/R	

: 10ms

Approvals:

2

•• UL Recognized component
•• AC: UL guide JFHR2
File E60314

Catalog Numbers (amps)

Fuse Holders for A60Q Fuses

A60Q5-2

A60Q20-2

USM Series......UltraSafeTM Fuse Holders

A60Q6-2

A60Q25-2

303 Series........Midget Fuse Blocks

A60Q8-2

A60Q30-2

A60Q10-2

A60Q35-2

A60Q12-2

A60Q40-2

•• DC: UL file E60314

A60Q15-2

* For ampere ratings and styles not listed,
call Technical Services at 978-465-4853.

D10

1-1/2”
(38.1 mm)

13/32”
(10.3 mm)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A60X Semiconductor Protection Fuses
A60X Amp-Trap® Form 101 Semiconductor Protection fuses are popular for the
protection of higher voltage heavy rectifiers such as traction rectifiers. They can carry
long sustained overloads common with heavy duty apparatus. 700A through 2000A
sizes are of compact, hockey-puck design, able to provide high power protection in a
small space.

Features/Benefits:
•• Low I2t minimizes damage to protected components on short circuit
•• Controlled arc voltage reduces stress to circuit components during fuse clearing

Highlights:

Applications:

•• Fast acting

•• Protection of heavy traction and

•• Current limiting

electrochemical as well as rectifiers

•• Low I2t

and other heavy-duty equipment

•• Indicator options available

Ratings:
Volts	

Catalog
Numbering System
		
A

			

D

•• Choice of mounting types helps in equipment design

60

: 600VAC

Amps	 : 1 to 2000A
X

600 - 4

TI

I.R.	

: 100kA I.R. AC

Amp-Trap® Fuse				
A
	

60

Rated Volts - 25	
	

X

Style

600
Amperes*		
Mounting Types*	
Ferrule			
Blades, bolt-in	

1
4
128

Hockey puck, bolt-in		
Integral Blown-Fuse
Indicator

TI
TA

Approvals:
•• UL recognized component
UL file E60314
•• AC: UL guide no. JFHR2
(35-800A)

Trigger Indicator (see pg. J5)		
Trigger Actuator (see pg. J5)		
* For ampere ratings and styles not listed, call Technical Services at
978-465-4853.

Single Pole Fuse Blocks for A60X Fuses
Fuse Ampere Rating

Fuse Block Catalog No.

1-30

60316

31-60

P243C

61-100

P243C

101-200

P243C

201-400

P266A

401-600

P266A

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D11

A60X Semiconductor Protection Fuses
Catalog Numbers (amps)
Catalog No.

Dimen. Fig.

Catalog No.

Dimen. Fig.

Catalog No.

Dimen. Fig.

A60X1-1

1

A60X80-4TA

4

A60X400-4

3

A60X2-1

1

A60X90-4

3

A60X400-4TA

4

A60X3-1

1

A60X100-4

3

A60X400-4TI

3

A60X4-1

1

A60X100-4TA

4

A60X450-4

3

A60X5-1

1

-

3

A60X450-4TA

4

A60X6-1

1

A60X125-4

3

A60X500-4

3

A60X7-1

1

A60X125-4TA

4

A60X500-4TA

4

A60X8-1

1

A60X150-4

3

A60X500-4TI

3

A60X10-1

1

A60X150-4TA

4

A60X600-4

3

A60X12-1

1

A60X175-4

3

A60X600-4TA

4

A60X15-1

1

A60X200-4

3

A60X600-4TI

3

A60X20-1

1

A60X200-4TA

4

A60X700-4

5

A60X25-1

1

A60X200-4TI

3

A60X700-128

7

A60X30-1

1

A60X225-4

3

A60X800-4

5

A60X35-4

2

A60X250-4

3

A60X800-4TA

6

A60X40-4

2

A60X250-4TA

4

A60X800-128

7

A60X45-4

2

A60X250-4TI

3

A60X1000-128

8

A60X50-4

2

A60X300-4

3

A60X1200-128

8

A60X55-4

2

A60X300-4TA

4

A60X1500-128

8

A60X60-4

2

A60X300-4TI

3

A60X1600-128

8

A60X70-4

3

A60X350-4

3

A60X1800-128

8

A60X80-4

3

A60X350-4TA

4

A60X2000-128

8

Figure 1

Figure 2

Figure 3

Figure 4

* For ampere ratings and styles not listed, call Technical Services at 978-465-4853.

Dimensions
Outline

Mounting

Ref.

Type

A60X1 to 30

1

A60X35 to 60

4

Fig.
1

2

A60X70 to 100

4, 4TI*, 4TA

3, 4*

A60X125 to 200

4, 4TI*, 4TA

3, 4*

A60X225 to 400

4, 4TI*, 4TA

3, 4*

A60X450 to 600

4, 4TI*, 4TA

3, 4*

A60X700 to 800

4, 4TA*

5, 6*

A60X700 to 800

128

7

A60X1000 to 1200

A60X1500 to 2000

128

128

8

8

Dimensions - Inches (mm)

Tap

A

B

C

D

E

F

G

H

5.00

.81

-

-

-

-

-

-

(127)

(20.6)

-

-

-

-

-

-

4.38

.81

2.78

3.69

3.44

.34

.72

.13

(111)

(20.6)

(70.6)

(93.7)

(87.4)

(8.6)

(18.3)

(3.3)

4.41

1.00

2.91

3.72

3.59

.31

.75

.13

(112)

(25.4)

(73.9)

(94.5)

(91.2)

(7.9)

(19.1)

(3.3)

4.41

1.22

2.91

3.72

3.59

.31

1.00

.19

(112)

(31.0)

(73.9)

(94.5)

(91.2)

(7.9)

(25.4)

(4.8)

5.13

1.50

2.88

4.19

3.56

.41

1.00

.25

(130)

(38.1)

(73.2)

(106)

(90.4)

(10.4)

(25.4)

(6.4)

5.13

2.00

2.88

4.06

3.69

.41

1.50

.25

(130)

(50.8)

(73.2)

(103)

(93.7)

(10.4)

(38.1)

(6.4)

7.25

2.50

3.00

5.94

4.56

.53

2.00

.38

(184)

(63.5)

(76.2)

(151)

(116)

(13.5)

(50.8)

(9.7)

4.00

3.00

3.75

2.50

1.50

-

-

-

3/8-24-1/2

(102)

(76.2)

(95.3)

(63.5)

(38.1)

-

-

-

Deep

4.00

3.50

3.75

3.00

1.50

1.50

-

-

3/8-24-1/2

(102)

(88.9)

(95.3)

(76.2)

(38.1)

(38.1)

-

-

Deep

4.00

4.50

3.75

3.75

1.50

1.50

-

-

1/2-20-1/2

(102)

(114)

(95.3)

(95.3)

(38.1)

(38.1)

-

-

Deep

-

-

Figure 6
-

-

-

-

* Optional Trigger Actuator (TA) or Trigger Indicator (TI)

D12

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Figure 5

-

www.barr-thorp.com

Figure 7

Figure 8

A070gRB Semiconductor Protection Fuses
The A070gRB is a fast acting, full range fuse utilized in the protection of inverters,
UPS and other discrete semi-conductor devices

Features/Benefits:
•• International 10 X 38 mm (1 1/2” X 13/32”) size for worldwide acceptance
•• Ferrule mount 1 to 30A for design versatility
•• Low I2t for improved semiconductor protection

D

•• gR Class according to VDE 636-23 and IEC 269.4

Highlights:

Applications:

•• Extremely fast acting

•• Protection of small inverters, UPS 

•• Current limiting

systems, motor drives and similar 700V

•• Low I2t

or less equipment

•• Excellent cycling capability

Ratings:

•• gR

Catalog Numbers (amps)
Body
Size
(mm)

10 X 38

Ampere
Rating

Rated
Voltage
(VAC)

Melting
I2t (A2s)

Clearing I2t

: 550VDC

@ Rated
Voltage (A s)
2

I.R.	

: 160kA I.R. AC

Catalog

	

: 10kA I.R. DC

No.

L/R	

: 10ms

Watts Loss
@ 80%

@ 100%

Rated

Rated

Current

Current

Description

1

0.075

0.28

0.57

0.9

A070GRC01T13

Z330279

0.115

0.4

0.7

1.25

A070GRB1.25T13

X330001

1.5

0.185

0.63

0.81

1.5

A070GRB1.5T13

Y330002

2

0.42

1.43

1.1

2

A070GRB2T13

Z330003

2.5

0.88

3

1.15

2.1

A070GRB02.5T13

A330004

3

1.55

5.1

1.25

2.3

A070GRB03T13

B330005

4

4

13.2

1.35

2.6

A070GRB04T13

C330006

5

8.6

27.5

1.4

2.7

A070GRB05T13

D330007

15

48.5

1.5

2.9

A070GRB06T13

E330008

8

3.3

36.3

1.35

2.4

A070GRB08T13

F330009

10

5.4

60.5

1.85

3.4

A070GRB10T13

G330010

12.5

8.5

90.2

1.9

3.4

A070GRB12.5T13

H330011

16

16

160

2.3

4.1

A070GRB16T13

J330012

20

30

275

2.4

4.3

A070GRB20T13

K330013

25

58

520

2.7

4.7

A070GRB25T13

L330014

30

96

815

2.9

5

A070GRB30T13

M330015

700

: 700VAC

	

Amps	 : 1 to 30A

1.25

6

Volts	

Approvals:
•• UL recognized component
UL file E76491
•• IEC 269-4 compliance
•• AC: UL guide no. JFHR2

38mm (1.5”)
10mm (.39”)

10.3mm (.406”)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D13

A70QS French Cylindrical
These Premium Amp-Trap® French cylindrical semiconductor fuses are an extension
of the popular A7OQS product line. They are solid-fill 14mm and 22mm fuses, IEC
rated 690VAC, 200kA Interrupting and 700VDC, 100kA interrupting at 10ms time
constant. In addition, these fuses have an 890 VDC rating for capacitor discharge
applications up to 2.5ms time constant. All ampere ratings are available with a striker.
Applications include small inverter drives and UPS systems, with superior l2t for
improved protection and performance.

Features/Benefits:
•• International 14x51mm (2”x9/16”) and 22x58mm (2-1/4”x13/16”) sizes for
worldwide acceptance
•• Ferrule mount up to 100A for design versatility
•• Very low I2t for improved semiconductor protection
•• 690V IEC rated, tested at 760VAC; can be used up to 750VAC in U.S.
•• 700VDC rated for DC protection of equipment with L/R ≤10ms
•• Superior cycling ability for longer life on difficult cyclic loading applications
•• aR characteristic for semiconductor short- circuit protection

Ratings:
Volts	

: 690VAC

	

: 700VDC

Amps	 : 10 to 100A

Highlights:

Applications:

•• 14 x 51 and 22 x 58 sizes

•• Small inverters, UPS systems,

•• 690VAC IEC rated

motor drives and similar 700V or

(760VAC max.)

less equipment

•• 700VDC rated

I.R.	

: 200kA I.R. AC

	

: 100kA I.R. DC

IEC 	

: tested at 760VAC

Contact factory for details.	

•• Superior cycling ability
•• Low watts loss
•• Optional striker for visual/remote
Indication

Approvals:
•• UL recognized component

Catalog Numbering System

File E76491

		

A70 QS 20

			

14F

1

Amp-Trap® Fuse				
A
	
60
Style/Design	

•• CSA Certified
•• IEC 269-4 Compliance

Amperes*		 Q
Size - 14F= 14x51mm

30

22F= 22x58mm
Optional Striker-I

2

Fuseholder -see Section H.

D14

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A70QS French Cylindrical
Ratings and Application Data
Ampere
Rating

14 x 51

22 x 58

Max Clearing
I2t @ 700VAC
(A2s x 103)

Melting
I2t (A2s x
103)

Watts Loss @
Rated Current
(W)

Catalog Number
No Striker

With Striker

6

0.0013

0.017

2.0

A70QS6-14F

A70QS6-14FI

8

0.0024

0.027

2.8

A70QS8-14F

A70QS18-14FI

10

0.0043

0.04

3.5

A70QS10-14F

A70QS10-14FI

12

0.0054

0.06

4.4

A70QS12-14F

A70QS12-14FI

16

0.0132

0.10

4.8

A70QS16-14F

A70QS16-14FI

20

0.027

0.16

5.2

A70QS20-14F

A70QS20-14FI

25

0.053

0.27

5.8

A70QS25-14F

A70QS25-14FI

32

0.098

0.50

7.0

A70QS32-14F

A70QS32-14FI

40

0.13

0.70

10.7

A70QS40-14F

A70QS40-14FI

50

0.28

1.50

11.6

A70QS50-14F

A70QS50-14FI

10

0.0043

0.025

4.0

A70QS10-22F

A70QS10-22FI

15

0.008

0.049

6.2

A70QS15-22F

A70QS15-22FI

20

0.013

0.076

8.0

A70QS20-22F

A70QS20-22FI

25

0.02

0.125

10.0

A70QS25-22F

A70QS25-22FI

32

0.049

0.27

11.0

A70QS32-22F

A70QS32-22FI

40

0.088

0.48

13.0

A70QS40-22F

A70QS40-22FI

50

0.16

0.80

14.9

A70QS50-22F

A70QS50-22FI

63

0.35

1.85

16.0

A70QS63-22F

A70QS63-22FI

70

0.52

2.80

16.5

A70QS70-22F

A70QS70-22FI

80

0.73

3.80

17.8

A70QS80-22F

A70QS80-22FI

90

1.10

5.64

17.0

A70QS90-22F

A70QS90-22FI

100

1.56

8.00

19.0

A70QS100-22F

A70QS100-22FI

D

Body
Size
(mm)

*100kA, L/R = 11.6ms

No Striker
Fuse Size

With Striker
Dimensions-mm
A

B

C

14 X 51

14

51

14

22 X 58

22

58

16

Fuse Size

Dimensions-mm
A

B

C

D

E

14 X 51

14

51

14

7.5

3.8

22 X 58

22

58

16

7.5

3.8

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D15

A70QS Amp-Trap

®

Form 101

A70QS Amp-Trap® Semiconductor Protection fuses were developed in response to
the need for improved overall performance of 700V semiconductor fuses for new
equipment requirements. A70QS fuses have lower I2t for better protection, longer life
when subjected to cyclic loading, plus lower watts loss. A70QS is the best choice to
protect dynamic solid state equipment such as motor drives, UPS, etc.

Features/Benefits:
•• Very Low I2t for improved protection of equipment
•• Superior cycling ability for long, reliable life on high cyclic loading
•• Low watts loss for cooler operation
•• 700V AC/DC rating gives greater design versatility
•• Ultra compact sizes allow down-sizing of existing equipment

Highlights:

Applications:

Ratings:

•• 700V AC/DC rated

•• Protection of 700V or less motor

Volts	

•• Very low I t

drives, UPS, inverters, etc.

2

•• Low watts loss
•• Superior cycling ability
•• All available with indicator (IL)

: 700VAC / DC

Amps	 : 35 to 800A
I.R.	

: 200kA I.R. AC

	

: 100kA I.R. DC

L/R 	

: 10ms

Catalog Numbering System

		

A

			

70

QS 150

4

	Amp-Trap® Fuse				
	
	
	

Rated Volts		

Approvals:

	Style

•• UL recognized component,
AC/DC UL file E60314

	Amperes*		
	

Mounting Types	

	

Blades, bolt-in

•• AC: guide no. JFHR2
•• DC: tested to UL standard 198L
parameters (35-800A)
•• CSA certified File LR 12636

Single Pole Fuse Blocks for
A70QS Fuses

D16

Fuse Mounting

Fuse Ampere

Type

Rating

A70QS-4

35-200

P243C

A70QS-4K

125-200

P266A

A70QS-4

225-600

P266A

A70QS-4K

450-600

FH70F3

A70QS-4

700-800

ISC375

Catalog No.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A70QS Amp-Trap

®

Form 101

Catalog Numbers (amps)
A7OQS35-4

A7OQS100-4

A7OQS200-4

A7OQS450-4K

A7OQS40-4

A7OQS125-4

A7OQS200-4K

A7OQS500-4

A7OQS50-4

A7OQS125-4K

A7OQS250-4

A7OQS500-4K

A7OQS60-4

A7OQS150-4

A7OQS300-4

A7OQS600-4

A7OQS70-4

A7OQS150-4K

A7OQS350-4

A7OQS600-4K

A7OQS80-4

A7OQS175-4

A7OQS400-4

A7OQS700-4

A7OQS90-4

A7OQS175-4K

A7OQS450-4

A7OQS800-4

D

* For ampere ratings and styles not listed (including indicators), call
Technical Services at 978-465-4853.

Dimensions
Outline Ref.

Mounting Type

A70QS35 to 100

4

A70QS125 to 200
A70QS125 to 200
A70QS225 to 400
A70QS450 to 600
A70QS450 to 600
A70QS700 to 800

4
4K
4
4
4K
4

Dimensions - Inches (mm)
A

B

C

D

E

F

G

H

4.38

1.00

2.88

3.69

3.50

0.31

0.75

0.13

(111)

(25.4)

(73.0)

(93.6)

(88.9)

(7.9)

(19.0)

(3.2)

4.38

1.22

2.88

3.69

3.56

0.31

1.00

0.19

(111)

(31.0)

(73.0)

(93.6)

(90.5)

(7.9)

(25.4)

(4.8)

5.09

1.22

2.88

4.19

3.50

0.41

1.00

0.19

(129)

(31.0)

(73.0)

(106)

(88.0)

(10.3)

(25.4)

(4.8)

5.09

1.50

2.84

4.16

3.53

0.40

1.50

0.25

(129)

(38.1)

(72.2)

(106)

(89.7)

(10.3)

(38.1)

(6.4)

5.09

2.00

2.84

4.16

3.53

0.41

1.50

0.25

(129)

(50.8)

(72.2)

(106)

(89.7)

(10.3)

(38.1)

(6.4)

7.09

2.00

2.84

6.16

3.53

0.53

1.50

0.25

(180)

(50.8)

(72.2)

(156)

(89.7)

(13.5)

(38.1)

(6.4)

7.09

2.50

2.84

5.28

4.91

0.53

2.00

0.38

(180)

(63.5)

(72.2)

(134)

(125)

(13.5)

(50.8)

(9.5)

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D17

A70P Amp-Trap

®

Form 101

A70P Amp-Trap® Form 101 Semiconductor Protection fuses were developed for
higher voltage AC and DC drives, UPS systems, reduced voltage motor starters and
similar applications where lower l2t and superior reliability are needed. A70P is a very
popular fuse, available in a wide range of ratings. Typically used for replacement.

Features/Benefits:
•• Low I2t minimizes damage to protected components on short circuit
•• Controlled arc voltage reduces stress to circuit components during fuse clearing
•• Choice of mounting types helps in equipment design

Highlights:

Applications:

•• Very fast acting

•• Protection of 700V or less DC

•• Current limiting

drives, UPS, inverters, reduced

•• Low I2t

voltage starters, etc.

•• Indicator options available

*Contact technical services for application data.

Catalog Numbering System
		

A

			

70

P

300

4

Amp-Trap Fuse				
A
	
70

Style

P

(Faster acting, lower I2t than X)

Volts	

: 700VAC

	

: 650VDC

Amps	 : 10 to1000A (AC)

TI

®

Rated Volts - 700		
	

Ratings:

	

: 10 to 800A (DC)

I.R.	

: 100kA I.R. AC

	

: 100kA I.R. DC

L/R 	

: 10ms

Amperes*		300
Mounting Types*	
Ferrule	

1

Blades, bolt-in	

4

Approvals:

Hockey puck, bolt-in		
28

•• UL recognized component UL

Integral Blown-Fuse

•• AC: guide no. JFHR2

Indicator

TI
TA

Trigger Indicator (see pg. J5)		
Trigger Actuator (see pg. J5)	

File E60314
* For ampere ratings and styles
not listed, call Technical Services
at 978-465-4853.

(10-1000A)
•• DC: tested to UL standard 198L
parameters (10-800A)

Single Pole Fuse Blocks
for A70P Fuses
Fuse Ampere
Rating

D18

Catalog No.

10-30 (Type 1)

70316

31-60

P243C

61-100

P243C

101-200

P266A

201-400

P266A

401-600

P266F

601-800

1SC375

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A70P Amp-Trap

®

Form 101

Catalog Numbers (amps)
Dimen. Fig.

Catalog No.

Dimen. Fig.

Catalog No.

Dimen. Fig.

A70P10-1

1

A70P80-4

3

A70P300-4

3

A70P10-4

2

A70P80-4TA

4

A70P350-4

3

A70P15-1

1

A70P80-4TI

3

A70P400-4

3

A70P15-4

2

A70P90-4

3

A70P400-4TA

4

A70P20-1

1

A70P100-4

3

A70P400-4TI

3

A70P25-1

1

A70P100-4TA

4

A70P450-4

3

A70P25-4

2

A70P125-4

3

A70P500-4

3

A70P30-1

1

A70P125-4TA

4

A70P600-4

3

A70P30-4

2

A70P150-4

3

A70P600-4TA

4

A70P35-4

3

A70P150-4TA

4

A70P600-4TI

3

A70P40-4

3

A70P150-4TI

3

A70P700-4

5

A70P40-4TA

4

A70P175-4

3

A70P700-4TI

5

A70P40-4TI

3

A70P200-4

3

A70P800-4

5

A70P50-4

3

A70P200-4TA

4

A70P800-4TI

5

A70P60-4

3

A70P200-4TI

3

A70P900-4

6

A70P60-4TA

4

A70P225-4

3

A70P1000-4

6

A70P60-4TI

3

A70P250-4

3

A70P70-4

3

A70P250-4TA

4

A70P70-4TI

3

A70P250-4TI

3

D

Catalog No.

* For ampere ratings and styles not listed, call Technical Services at 978-465-4853.

Dimensions
Outline

Mounting

Ref.

Type

A70P10 to 30

1

1

A70P10 to 30

4

2

Fig.

A70P35 to 60

4, 4TA*, 4TI

3, 4*

A70P70 to 100

4, 4TA*, 4TI

3, 4*

A70P125 to 200
A70P225 to 400
A70P450 to 600

4, 4TA*, 4TI
4, 4TA*, 4TI
4, 4TA*, 4TI

3, 4*
3, 4*
3, 4*

A70P700 to 800

4, 4TI

5

A70P900 to 1000

4, 4TI

6

Figure 1

Dimensions - Inches (mm)
A

B

C

D

E

F

G

H

J

2.00

.56

-

-

-

-

-

-

-

(50.8)

(14.2)

-

-

-

-

-

-

-

2.88

.56

1.88

2.50

-

.27

.41

-

-

(73.2)

(14.2)

(47.8)

(63.5)

-

(6.9)

(10.4)

-

-

4.38

1.00

2.88

3.69

3.56

.31

.75

.06

-

(111)

(25.4)

(73.2)

(93.7)

(90.4)

(7.9)

(19.1)

(1.5)

-

4.38

1.22

2.88

3.69

3.56

.31

1.00

.19

-

(111)

(31.0)

(73.2)

(93.7)

(90.4)

(7.9)

(25.4)

(4.8)

-

5.09

1.50

2.84

4.16

3.53

.41

1.00

.25

-

(129)

(38.1)

(72.1)

(106)

(89.7)

(10.4)

(25.4)

(6.4)

-

5.09

2.00

2.84

4.16

3.53

.41

1.50

.24

-

(129)

(50.8)

(72.1)

(106)

(89.7)

(10.4)

(38.1)

(6.4)

-

7.09

2.50

2.84

5.25

4.94

.53

2.00

.38

-

(180)

(63.5)

(72.1)

(133)

(125)

(13.5)

(50.8)

(9.7)

-

6.81

2.88

3.31

5.31

-

.63

2.00

.38

.31

(173)

(73.2)

(84.1)

(135)

-

(16.0)

(50.8)

(9.7)

(7.9)

7.59

3.50

3.84

5.97

5.22

.63

2.75

.50

1.38

(193)

(88.9)

(97.5)

(152)

(133)

(16.0)

(69.9)

(12.7)

(35.1)

Figure 3

Figure 2

Figure 4

* Optional Trigger
Actuator (TA)	

Figure 5

Figure 6

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D19

A70Q Amp-Trap

®

Form 101

A70Q Amp-Trap® Semiconductor Protection fuses were developed for inverter
applications requiring extremely low I2t. A70Q fuses provide the most responsive
protection for applications not required to sustain heavy overloads. Typically used for
replacement purposes.

Features/Benefits:
•• Lowest I2t of any fuse in this voltage rating for best overall protection
•• 700V AC, 650V DC rating allows protection of greater variety of circuits
•• Solid fill technology for extra reliability in performance

Highlights:

Applications:

•• Extremely fast acting

•• Protection of inverters and other

•• Current limiting

equipment requiring the best AC

•• Lowest I t

or DC protection in this

Ratings:

voltage range

Volts	

: 700VAC

	

: 650VDC

2

Amps	 : 35 to 600A

Catalog Numbering System
		

A

			

70

Q

150 - 4

I.R.	

: 100kA I.R. AC / DC

L/R	

: 10ms

Amp-Trap® Fuse				
A
	
70
Rated Volts - 700		
	
Style

Q

Amperes*		
500
Mounting Types	
Blades, bolt-in

4

* For ampere ratings and styles not listed, call Technical
Services at 978-465-4853.	

Approvals:
•• UL recognized component
UL File E60314
•• AC: guide no. JFHR2
•• DC: tested to UL standard 198L

Single Pole Fuse Blocks
for A70Q Fuses

D20

Fuse Ampere

Fuse Block

Rating

Catalog No.

35-100

P243C

125-400

P266A

450-600

P266F

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

parameters (35-600A)

www.barr-thorp.com

A70Q Amp-Trap

®

Form 101

Catalog Numbers (amps)
A70Q35-4

A70Q100-4

A70Q350-4

A70Q40-4

A70Q125-4

A70Q400-4

A70Q50-4

A70Q150-4

A70Q450-4

A70Q60-4

A70Q175-4

A70Q500-4

A70Q70-4

A70Q200-4

A70Q600-4

A70Q80-4

A70Q250-4

A70Q90-4

A70Q300-4

D

* For ampere ratings and styles not listed, call Technical Services
at 978-465-4853.

Dimensions
Catalog No.

Mounting Type

A70Q35 to 60

4

A70Q70 to 100

4

Dimensions - Inches (mm)
A

B

C

D

E

F

G

H

4.37

1.22

1.96

3.69

2.91

.34

1.00

.19

(111)

(31.0)

(49.8)

(93.7)

(73.9)

(8.6)

(25.4)

(4.8)

4.37

1.22

1.96

3.69

2.91

.41

1.00

.19

(111)

(31.0)

(49.8)

(93.7)

(73.9)

(10.4)

(25.4)

(4.8)

1.50

1.96

4.16

2.91

.41

1.00

.25

A70Q125 to 200

4

5.09
(129)

(38.1)

(49.8)

(106)

(73.9)

(10.4)

(25.4)

(6.4)

A70Q250 to 400

4

5.09

2.00

1.96

4.00

2.94

.56

1.50

.25

(129)

(50.8)

(49.8)

(102)

(74.7)

(14.2)

(38.1)

(6.4)

7.09

2.50

1.96

5.72

3.25

.56

2.00

.38

(180)

(63.5)

(49.8)

(145)

(82.6)

(14.2)

(50.8)

(9.7)

A70Q450 to 600

4

Figure 1

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D21

A100P Amp-Trap

®

Form 101

A100P Amp-Trap® Form 101 Semiconductor Protection fuses are rated 1000V,
extending the range of protection for UPS systems, AC and DC drives, reduced
voltage motor starters and similar applications where lower I2t and superior
reliability are needed. With ratings from 15 through 1000 amperes, a wide
range of high voltage applications can be served.

Features/Benefits:
•• Low I2t minimizes damage to protected components on short circuit
•• Controlled arc voltage reduces stress to circuit components during fuse clearing
•• Wide range of ampere ratings

Highlights:

Applications:

•• Fast acting

•• Protection of UPS systems AC/

•• Current limiting

DC drives, reduced voltage motor

•• Low I2t

starters and other 1000V or less

•• Optional trigger indicator

semiconductor devices

Ratings:
Volts	

: 1000VAC

	

: 750VDC

Amps	 : 15 to 1000A

Catalog Numbering System
		

A 100

			

P

80 - 4

TI

I.R.	

: 100kA I.R.

L/R	

: 25ms

Amp-Trap® Fuse				
A
	
100

Rated Volts - 700		
	
Style

P

Amperes*		80
Mounting Type	

Approvals:

1

Blades, bolt-in	

•• UL recognized component File

4

Integral Blown-Fuse
Trigger Indicator (see pg. J5)	 TI

E60314
* For ampere ratings and styles
not listed, call Technical Services
at 978-465-4853.

•• AC: UL guide no. JFHR2
(35-600A)
•• DC: self-certified

Single Pole Fuse Blocks
for A100P Fuses

D22

Fuse Ampere

Fuse Block

Rating

Catalog No.

35-100

P266G

125-400

P266L

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A100P Amp-Trap

Form 101

®

Catalog Numbers (amps)
Dimen. Fig.

Catalog No.

Dimen. Fig.

Catalog No.

Dimen. Fig.

A100P15-1

1

A100P100-4

2

A100P350-4TI

2

A100P20-1

1

A100P100-4TI

2

A100P400-4

2

A100P25-1

1

A100P125-4

2

A100P400-4TI

2

A100P30-1

1

A100P125-4TI

2

A100P500-4

3

A100P35-4

2

A100P150-4

2

A100P500-4TI

3

A100P40-4

2

A100P150-4TI

2

A100P600-4

3

A100P50-4

2

A100P200-4

2

A100P600-4TI

3

A100P50-4TI

2

A100P200-4TI

2

A100P650-4

4

A100P60-4

2

A100P225-4

2

A100P700-4

4

A100P60-4TI

2

A100P250-4

2

A100P800-4

4

A100P70-4TI

2

A100P300-4

2

A100P800-4TI

4

A100P80-4

2

A100P300-4TI

2

A100P1000-4

5

A100P80-4TI

2

A100P350-4

2

D

Catalog No.

* For ampere ratings and styles not listed, call Technical Services at 978-465-4853.

Dimensions
Outline Ref.

Mounting Type

Fig.

A100P15 to 30

1

1

A100P35 to 60

4, 4TI

2

A100P65 to 100

4, 4TI

2

A100P125 to 200

4, 4TI

2

A100P225 to 400
A100P500 to 600
A100P650 to 800
A100P1000

4, 4TI
4, 4TI
4, 4TI
4

2
3
4
5

Dimensions - Inches (mm)
A

B

C

D

E

F

G

H

J

2.63

0.56

-

-

-

-

-

-

-

(66.8)

(14.2)

-

-

-

-

-

-

-

5.00

1.00

3.50

4.31

4.19

0.31

0.75

0.13

-

(127)

(25.4)

(173)

(109)

(106)

(7.9)

(19.1)

(3.3)

-

5.00

1.22

3.50

4.31

4.19

0.31

1.00

0.19

-

(127)

(31.0)

(173)

(109)

(106)

(7.9)

(25.4)

(4.8)

-

5.72

1.50

3.47

4.78

4.16

0.41

1.00

0.25

-

(145)

(38.1)

(88.1)

(121)

(106)

(10.4)

(25.4)

(6.4)

-

5.72

2.00

3.47

4.78

4.16

0.41

1.50

0.25

-

(145)

(50.8)

(88.1)

(121)

(106)

(10.4)

(25.4)

(6.4)

-

7.72

2.50

3.47

5.88

5.56

0.53

2.00

0.38

-

(196)

(63.5)

(88.1)

(149)

(141)

(13.5)

(50.8)

(9.7)

-

7.44

2.88

3.94

5.94

-

0.63

2.00

0.38

(189)

(73.2)

(100)

(151)

-

(16.0)

(50.8)

(9.7)

-

8.22

3.50

4.47

6.59

5.84

0.63

2.75

0.50

1.38

(209)

(88.9)

(114)

(167)

(148)

(16.0)

(69.9)

(12.7)

(35.1)

Figure 3

Figure 2

Figure 1

Figure 4

-

Figure 5

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D23

A120X Amp-Trap

®

Form 101

A120X Amp-Trap® Form 101 Semiconductor Protection fuses, rated 1/2A through
30A, 1200VAC are popular for use in traction drive auxiliary circuits and similar
applications. A120X fuses are also suitable for use on 1000VDC auxiliary circuits with
low time constants.

Features/Benefits:
•• 1000V DC rated for wide range of circuits
•• Compact size fits in where competitive sizes will not fit

Highlights:

Applications:

•• Fast acting

•• Protection of traction drive

•• Current limiting

auxiliary circuits, etc.

•• Low I2t
•• Compact size

Catalog Numbering System
		

A 120

			

X

Ratings:

25 - 1

Volts	

: 1200VAC

Amp-Trap Fuse				
A
	
120
Rated Volts - 1200		
	

	

: 1000VDC

Style
(Fast acting, low l2t)

®

Amps	 : 1/2 to 30A

X

I.R.	

: 100kA I.R. AC

	

: 100kA I.R. DC

L/R	

: 10ms

Amperes*		25
Common Mounting Type*	 1

* For ampere ratings and types not
listed, consult the factory.

Ferrule

Single Pole Fuse Blocks for A120X Fuses
Ampere Ratingting
1/2-30

Catalog No.
P292

Approvals:
•• UL recognized component
File E 60314

Catalog Numbers (amps)
A120X1/2-1

A120X6-1

A120X1-1

A120X10-1

A120X2-1

A120X15-1

A120X3-1

A120X20-1

A120X4-1

A120X25-1

A120X5-1

A120X30-1

Dimensions - In (mm)

D24

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A150X Amp-Trap

Form 101

®

A150X Amp-Trap® Form 101 Semiconductor Protection fuses, rated up to 1000A,
1500VAC are suitable for traction drive and auxiliary circuits and for High Voltage
Heavy duty rectifier applications. A150X fuses are suitable for use up to 1500VDC on
circuits depending on time constant.

Features/Benefits:
•• 1500V AC rated for wide range of applications
•• Heavy duty links

D

•• Rugged fiberglass body

Highlights:

Applications:

•• Fast acting

•• Protection of traction drive and

•• Current limiting

auxiliary circuits, etc.

•• Low I t
2

Ratings:

Catalog Numbers (amps)

Volts	

: 1500VAC

	

: 1000VDC

Catalog No.

Dimen. Fig.

Catalog No.

Dimen. Fig.

A150X1-1

1

A150X90-4

2

Amps	 : 1A to 1000A

A150X15-1

1

A150X100-4

2

I.R.	

: 100kA I.R. AC

A150X15-4

2

A150X125-4

2

A150X20-1

1

A150X150-4

2

	

: 100kA I.R. DC

A150X20-4

2

A150X175-4

2

A150X25-4

2

A150X200-4

2

A150X30-1

1

A150X250-4

2

A150X40-4

2

A150X300-4

2

A150X35-4

2

A150X400-4

2

A150X40-4

2

A150X450-4

2

A150X50-4

2

A150X500-4

2

A150X60-4

2

A150X600-4

2

A150X70-4

2

A150X800-4

2

A150X80-4

2

A150X1000-4

2

Approvals:
• Self-certified

Dimensions

Figure 1

Outline

Mounting

Ref.

Type

A150X1 to 30

1

1

A150X15 to 60

4

2

Fig.

A150X70 to 100

4

2

A150X125 to 300

4

2

A150X400 to 600

A150X800 to 1000

4

4

2

3

Dimensions - Inches (mm)
A

B

C

D

E

F

G

H

J

7.15

1.21

5.62

6.46

6.34

0.31

1.00

0.18

-

(182)

(31)

(143)

(164)

(161)

(8)

(25)

(3)

-

7.87

1.50

5.62

6.93

6.31

0.40

1.00

.025

-

(127)

(31)

(173)

(176)

(160)

(10)

(25)

(6)

-

7.87

2.00

5.62

6.93

6.31

0.40

1.50

0.25

-

(145)

(38)

(88)

(176)

(160)

(10)

(38)

(6)

-

9.75

2.50

6.62

8.31

8.06

0.56

2.00

0.25

-

(145)

(51)

(88)

(211)

(205)

(14)

(51)

(6)

-

9.87

3.50

6.12

8.03

7.71

0.56

2.75

0.37

1.37

(251)

(89)

(155)

(204)

(196)

(14)

(70)

(9)

(35)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Figure 2

Figure 2

www.barr-thorp.com

D25

6,9 gRB-URB European Semiconductor Fuses
690V
gRB-URB FROM 12 TO 100A
Size: 17 x 49
Features/Benefits:
•• Extremely high Interrupting rating
•• Protection of power semiconductors as per IEC standard 269.4
•• 690V rating as per IEC 33
•• gR class [current rating 12 to 90A] as per VDE 636-23			
-Full range protection				
-Improved safety and protection			
-Allows selective coordination
•• aR class [current rating 100A] according to VDE 636-23 and IEC 269.4
•• Connections as per: 				
-German Standard DIN 43653/00C			
-British Standard BS 88-4
•• These fuses are UL recognized

Applications Data
Voltage
Rating

Class

UN(V)

690

690

gRB

URB

Current

Melting I2t

Total Clearing

Rating

@ 1 ms

I2t @ Rated

IN(A)

(A2s)

Voltage (A2s)

0.8 IN

IN

12

4.2

30

1.95

3.5

16

9.6

65

2.2

4.0

20

17.1

110

3.0

5.5

25

26.8

170

4.4

8.0

32

52.5

330

5.0

9.0

35

69

430

5.2

9.5

40

96

610

5.8

10.5

45

130

820

6.3

11.5

50

154

970

7.2

13

55

210

1320

7.4

13.5

63

310

1950

8.0

14.5

75

520

3250

8.8

16

80

620

3900

9.4

17

90

840

5300

11

20

100

965

6150

13

23.5

Watts Loss

Tested

Estimated

Interrupting

Interrupting

Rating

Rating

200 k A

300 k A

@ 690 V

@ 690 V

Minimum operating voltage for separate trip-indicator: 20 V

D26

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

German Standard without Blown Fuse Indication
46.2
18.5
1.5
96
69.4 - 81
16

8.73
x18
15.5

Weight: 40 g
Packaging: 10 pieces

German Standard with Separate Blown Fuse
Trip-Indicator DIN 43623/00C

Weight: 40 g
Packaging: 10 pieces

British Standard without Blown Fuse Indication

Weight: 37 g
Packaging: 10 pieces

British Standard with Separate Blown Fuse
Trip-Indicator BS 88-4

Weight: 37 g
Packaging: 10 pieces

Current Rating

Description

Catalog No.

12

6,9 gRB 17 DO8/12

M220972

16

6,9 gRB 17 DO8/16

N220973

20

6,9 gRB 17 DO8/20

P220974

25

6,9 gRB 17 DO8/25

Q22097a5

32

6,9 gRB 17 DO8/32

R220976

35

6,9 gRB 17 DO8/35

S220977

40

6,9 gRB 17 DO8/40

T220978

45

6,9 gRB 17 DO8/45

V220979

50

6,9 gRB 17 DO8/50

W220980

55

6,9 gRB 17 DO8/55

X220981

63

6,9 gRB 17 DO8/63

Y220982

75

6,9 gRB 17 DO8/75

Z220983

80

6,9 gRB 17 DO8/80

A220984

90

6,9 gRB 17 DO8/90

B220985

100

6,9 URB 17 DO8/100

C220986

Current Rating

Description

Catalog No.

12

6,9 gRB 17 DO8P 12

X221004

16

6,9 gRB 17 DO8P 16

Y221005

20

6,9 gRB 17 DO8P 20

Z221006

25

6,9 gRB 17 DO8P 25

A221007

32

6,9 gRB 17 DO8P 32

B221008

35

6,9 gRB 17 DO8 P 35

C221009

40

6,9 gRB 17 DO8P 40

D221010

45

6,9 gRB 17 DO8P 45

E221011

50

6,9 gRB 17 DO8P 50

F221012

55

6,9 gRB 17 DO8P 55

G221013

63

6,9 gRB 17 DO8P 63

H221014

75

6,9 gRB 17 DO8P 75

J221015

80

6,9 gRB 17 DO8P 80

K221016

90

6,9 gRB 17 DO8P 90

L221017

100

6,9 URB 17 DO8P 100

M221018

Current Rating

Description

Catalog No.

12

6,9 gRB 17/12

W220957

16

6,9 gRB 17/16

X220958

20

6,9 gRB 17/20

Y220959

25

6,9 gRB 17/25

Z220960

32

6,9 gRB 17/32

A220961

35

6,9 gRB 17/35

B220962

40

6,9 gRB 17/40

C220963

45

6,9 gRB 17/45

D220964

50

6,9 gRB 17/50

E220965

55

6,9 gRB 17/55

F220966

63

6,9 gRB 17/63

G220967

75

6,9 gRB 17/75

H220968

80

6,9 gRB 17/80

J220969

90

6,9 gRB 17/90

K220970

100

6,9 URB 17/100

L220971

Current Rating

Description

Catalog No.

12

6,9 gRB 17P12

D220987

16

6,9 gRB 17P16

E220988

20

6,9 gRB 17P20

F220989

25

6,9 gRB 17P25

G220990

32

6,9 gRB 17P32

H220991

35

6,9 gRB 17P35

J220992

40

6,9 gRB 17P40

K220993

45

6,9 gRB 17P45

L220994

50

6,9 gRB 17P50

M220995

55

6,9 gRB 17P55

N220996

63

6,9 gRB 17P63

P220997

75

6,9 gRB 17P75

Q220998

80

6,9 gRB 17P80

R220999

90

6,9 gRB 17P90

S221000

100

6,9 URB 17P100

T221001

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D

6,9 gRB-URB European Semiconductor Fuses

D27

6,9 gRB-URB DIN German Standard
German Standard
500 - 690V AC
gRB-URB FROM 20 TO 400A
Size: 000
Features/Benefits:
•• Extremely high interrupting rating
•• Protection of power semiconductors according to IEC 269.1 and EN 60269.4
•• 500-690V [Rating 20 to 400A]
•• gR class [gRB Ratings 20 to 125A] according to VDE 636-23		
-Full range protection				
-Improved safety and protection			
-Allows selective coordination
•• aR class [current rating 80 to 400A] according to VDE 636-23 and IEC 269.4
•• 3 models complying with DIN 43653-00C are:	
-With or without blown fuse indication		
-With trip indicator
•• Model complying with DIN 43620 (00C)		
-Standard with or without blown fuse indication		
-With trip indicator

Applications Data
Voltage
Rating

Class

UN(V)

690

gRB

690
URB
660
500

Current

Melting I2t Total Clearing

Rating

@ 1 ms

I2t @ Rated

IN(A)

(A2s)

Voltage (A2s)

Watts Loss
0.8 IN

IN

20

12

80

3.8

7

25

20

150

5.0

9

32

39

270

5.5

10

40

70

460

6.6

12

50

102

730

7.7

14

63

210

1500

8.8

16

80

475

2900

9.9

18

100

970

6000

11

20

125

1900

11800

11.6

21

80

390

2500

11.6

21

100

690

4200

12.7

23

125

1300

8900

14.3

26

160

2700

16000

17.0

31

200

5250

31500

19.8

36

250

9900

52000

24.8

45

315

15500

82000

31.9

58

350

22400

110000

31.9

58

400

33200

160000

36.3

66

Tested

Estimated

Interrupting

Interrupting

Rating

Rating

200 k A
@ 660 V

300 k A
@ 660 V

120 k A
@ 500 V

Minimum operating voltage for blown fuse indicator: 20 V

D28

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

6,9 gRB-URB DIN German Standard
German Standard Blade-Type DIN 43620**

Weight: 150 g
Packaging: 3 pieces
Microswitches
MS 4L 2-5 B6 + PRES Ref. F210156
MS 4L 2-5 B2 + PRES Ref. G210157
* Fuse Base: 41002-G

Description

Cat. No.

16
20
25
32
40
50
63
80
100
125
80
100
125
160
200
250
315
350
400

6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
5
5

Y210609
Z210610
A210611
B210612
C210613
D210614
E210615
F210616
G210617
H210618
Q320059
V320063
X320065
B320069
D320071
: 500 H320075
M320079
R210626
S210627

GRB 000 PV 016
GRB 000 PV 020
GRB 000 PV 025
GRB 000 PV 032
GRB 000 PV 040
GRB 000 PV 050
GRB 000 PV 063
GRB 000 PV 080
GRB 000 PV 100
GRB 000 PV 125
URD 000 PV 0080
URD 000 PV 0100
URD 000 PV 0125
URD 000 PV 0160
URD 000 PV 0200
Volts	
URD 000 PV 0250
URD 000 PV 0315
URB 000 PV 350
URB 000 PV 400

Rating:

CI/IN

1
1
1
1
1
1
1
1
1
1
1
1
0,95
0,85
0,85
690V 0,8
0,7
0,7
0,65

D

Size

These fuses are not UL recognized.

German Standard without Blown Fuse Indicator

Weight: 110 g
Packaging: 6 pieces
* Fuse Base: SI 000 DIN 80
Ref. Number: C 220710

Size

Description

20
25
32
40
50
63
80
100
125
80
100
125
160
200
250
315
350
400

6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
6,9
5
5

GRB
GRB
GRB
GRB
GRB
GRB
GRB
GRB
GRB
URB
URB
URB
URB
URB
URB
URB
URB
URB

000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000

D330030
E330031
F330032
G330033
H330034
J330035
A330073
269.
and
S330112
T330113
K330036
L330037
M330038
N330039
P330040
Q330041
R330042
V330114
D330191

Approvals

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

CI/IN

Cat. No.

D08 / 020
D08 / 025
D08 / 032
D08 / 040
D08 / 050
D08 / 063
D08 •/ •080
IEC
D08 / 100
D08 / 125
D08 / 080
D08 / 100
D08 / 120
D08 / 160
D08 / 200
D08 / 250
D08 / 315
D08 / 350
D08 / 400

www.barr-thorp.com

EN

1
1
1
1
1
1
1
60269.4
1
0,9
1
1
0,9
0,85
0,85
0,8
0,7
0,7
0,65

D29

6,9 gRB-URB DIN German Standard
German Standard with Blown
Fuse Indication
Current Rating

Description

Cat. No.

I/N Fuse Base*

20

6,9 gRB 000 DO8V/020

P330017

1

25

6,9 gRB 000 DO8V/025

Q330018

1

32

6,9 gRB 000 DO8V/032

R330019

1

40

6,9 gRB 000 DO8V/040

S330020

1

50

6,9 gRB 000 DO8V/050

T330021

1

63

6,9 gRB 000 DO8V/063

V330022

1

80

6,9 gRB 000 DO8V/080

G330102

1

100

6,9 gRB 000 DO8V/100

Q330110

1

125

6,9 gRB 000 DO8V/125

R330111

0,9

80

6,9 URB 000 DO8V/080

W330023

1

100

6,9 URB 000 DO8V/100

X330024

1

125

6,9 URB 000 DO8V/125

Y330025

0,95

160

6,9 URB 000 DO8V/160

Z330026

0,85

200

6,9 URB 000 DO8V/200

A330027

0,85

250

6,9 URB 000 DO8V/250

B330028

0,8

315

6,9 URB 000 DO8V/315

C330029

0,7

350

5 URB 000 DO8V/350

W330115

0,7

400

5 URB 000 DO8V/400

E330192

0,65

*Fuse Base: SI 000 DIN 80
Ref. Number: C 220710

German Standard with Separate Blown
Fuse Trip-Indicator
Current Rating

Description

Cat. No.

I/N Fuse Base*

20

6,9 gRB 000 DO8L/020

J330173

1

25

6,9 gRB 000 DO8L/025

K330174

1

32

6,9 gRB 000 DO8L/032

L330175

1

40

6,9 gRB 000 DO8L/040

M330176

1

50

6,9 gRB 000 DO8L/050

N330177

1

63

6,9 gRB 000 DO8L/063

P330178

1

80

6,9 gRB 000 DO8L/080

Q330179

1

100

6,9 gRB 000 DO8L/100

R330180

1

125

6,9 gRB 000 DO8L/125

S330181

0,9

80

6,9 URB 000 DO8L/080

T330182

1

100

6,9 URB 000 DO8L/100

V330183

1

125

6,9 URB 000 DO8L/125

W330184

0,9

160

6,9 URB 000 DO8L/160

X330185

0,85

200

6,9 URB 000 DO8L/200

Y330186

0,85

250

6,9 URB 000 DO8L/250

Z330187

0,8

315

6,9 URB 000 DO8L/315

A330188

0,7

350

5 URB 000 DO8L/350

B330189

0,7

400

5 URB 000 DO8L/400

F330193

0,65

Microswitch
MC 4L 2-5 B6 + PRES Ref. Number: F210156
MC 4L 2-5 B2 + PRES Ref. Number: G210157
*Fuse Base: SI 000 DIN 80 Ref. Number: C220710

D30

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

BS88 British Standard
Protistor® Fuses
500-690V AC
gRB/URB from 20 to 400A
Size: 000
Features/Benefits:
•• Extremely high interrupting rating
•• Protection of power semiconductors according to IEC 269.1 and EN 60269.4

D

•• 500-690V (rating 20 to 400A)
•• gR class (gRB Ratings 20 to 125A) according to VDE 636-23.			
-Full range protection				
-Improving safety and protection			
-Allows selective coordination
•• aR class (URB ratings 75 to 400A) according to VDE 636-23 and IEC 269.4
•• Two models according to BS 88-4 and EN 60 269.4 standards: Z3 drawing (74mm
between axes) external open fuse with and without indicator

Applications Data
Voltage
Rating

Class

UN(V)

690

gRB

690
URB

660
500

Current

Melting I2t

Rating

@ 1 ms

IN(A)

(A2s)

Total Clearing
I2t @ UN I2tp
(A 2s)

Watts Loss
0.8 IN

IN

20

12

80

3.8

7

25

20

150

5.0

9

32

39

270

5.5

10

40

70

460

6.6

12

50

102

730

7.7

14

63

210

1500

8.8

16

80

475

2900

9.9

18

100

970

6000

11

20

125

1900

11800

11.6

21

75

350

2250

11.2

20.5

80

390

2500

11.6

21

100

690

4200

12.7

23

110

950

6800

13.5

24.5

125

1300

8900

14.3

26

160

2700

16000

17.0

31

200

5250

31500

19.8

36

250

9900

52000

24.8

45

315

15500

82000

31.9

58

350

22400

110000

31.9

58

160000

36.3

66

400

Tested

Estimated

Interrupting

Interrupting

Rating

Rating

200 k A
@ 660 V

300 k A
@ 660 V

120 k A
@ 500 V

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D31

BS88 British Standard
British Standard without Open Fuse
Indicator

British Standard with External Open
Fuse Trip-Indicator

The use of MC 6.3 GR 2-5N blown fuse remote sensing
microswitch is possible.
Ref. Number: Y 310015 mounted on separate trip-indicator.
See Microswitch section page J10, J12.

D32

Current Rating

Description

Cat. No.

20

6,9 gRB 000 BS88/020

T330044

25

6,9 gRB 000 BS88/025

V330045

32

6,9 gRB 000 BS88/032

W330046

40

6,9 gRB 000 BS88/040

X330047

50

6,9 gRB 000 BS88/050

Z330049

63

6,9 gRB 000 BS88/063

A330050

80

6,9 gRB 000 BS88/080

N330108

100

6,9 gRB 000 BS88/100

H330103

125

6,9 gRB 000 BS88/125

P330109

75

6,9 URB 000 BS88/075

B330051

80

6,9 URB 000 BS88/080

C330052

100

6,9 URB 000 BS88/100

D330053

110

6,9 URB 000 BS88/110

E330100

125

6,9 URB 000 BS88/125

E330054

150

6,9 URB 000 BS88/150

F330101

160

6,9 URB 000 BS88/160

F330055

200

6,9 URB 000 BS88/200

G330056

250

6,9 URB 000 BS88/250

H330057

315

6,9 URB 000 BS88/315

J330058

350

5 URB 000 BS88/350

X330116

400

5 URB 000 BS88/400

G330194

Current Rating

Description

Cat. No.

20

6,9 gRB 000 BS88P/020

Y330117

25

6,9 gRB 000 BS88P/025

Z330118

32

6,9 gRB 000 BS88P/032

A330119

40

6,9 gRB 000 BS88P/040

B330120

50

6,9 gRB 000 BS88P/050

C330121

63

6,9 gRB 000 BS88P/063

D330122

80

6,9 gRB 000 BS88P/080

E330123

100

6,9 gRB 000 BS88P/100

F330124

125

6,9 gRB 000 BS88P/125

G330125

75

6,9 URB 000 BS88P/075

H330126

80

6,9 URB 000 BS88P/080

J330127

100

6,9 URB 000 BS88P/100

K330128

110

6,9 URB 000 BS88P/110

L330129

125

6,9 URB 000 BS88P/125

M330130

150

6,9 URB 000 BS88P/150

N330131

160

6,9 URB 000 BS88P/160

P330132

200

6,9 URB 000 BS88P/200

Q330133

250

6,9 URB 000 BS88P/250

R330134

315

6,9 URB 000 BS88P/315

S330135

350

5 URB 000 BS88P/350

T330136

400

5 URB 000 BS88P/400

H330195

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Size 00 British Standard
Protistor® Fuses
690V
gRB-URB from 16 to 450A
Size: 00
Features/Benefits:
•• Extremely high Interrupting rating
•• Protection of power semiconductors according to IEC 269.1 and 4
•• 690V

D

•• gR class [gRB ratings 16 to 160 A] according to VDE 636-23		
-Full range protection				
-Improving safety and protection			
-Allows selective coordination
•• aR class [URC and URD Ratings 16 to 450A]
according to VDE 636-23 and IEC 269.4
•• Connections according to: 			
-DIN 43653/00C 80 and 110mm between axes	
-DIN 43620/00C solid blades
•• Optional pin indicator for operating a microswitch

Applications Data
Voltage
Rating

Class

UN(V)

gRB

690

URB

600

Current

Melting I2t

Rating

@ 1 ms

IN(A)

(A2s)

16

8

20

12

25

Total Clearing

Watts Loss

I2t @ UN I2t p
(A 2s)

Tested

Estimated

Interrupting

Interrupting

Rating

Rating

0.8 IN

IN

61

2.7

5

86

3.3

6

18

140

4.4

8

32

39

250

6.0

11

40

68

450

7.1

13

50

116

750

8.8

16

63

210

1400

9.9

18

80

525

3000

10.5

19

100

970

5400

10.7

19.5

125

1710

9600

13.2

24

160

4270

22400

13.7

25

16

7

52

3.8

7

20

10

75

5.0

9

25

15

120

6.0

11

200kA

300kA

32

32

210

8.2

15

@ 690V

@ 690V

40

61

400

9.9

18

50

102

700

11.5

21

63

177

1200

12.6

23

80

390

2200

13.8

25

100

692

3900

15.4

28

125

1170

6600

18.1

33

160

2680

14 000

19.8

36

200

4690

24 000

23.1

42

250

8300

42 500

27.5

50

315

17 520

81 000

31.9

58

350•

25 450

118 000

33.0

60

400•

33 200

150 000

38.5

70

450**

51 850

225 000

40.7

74

200kA @ 600V

300kA @ 600V

• Voltage rating: 690V with CC’ at 1s - 450V with CC’ at 10 s
**Voltage rating: 600V with CC’ at 1s - 450V with CC’ at 10 s
Note: voltage rating of 350-400-450 A rated fuses is defined with a CC’ curve at 1 second limited by the
minimum breaking current.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D33

Size 00 British Standard
German Standard According to DIN 43653/00C &
DIN 80 & 110 - Catalog Numbers (amps)
Description

gRB
DIN 80

Cat. No.

Description

I/N Fuse Base*

I/N Fuse

Cat. No.

Base*

6,9 URB 00 D08L 016

V330275

1

6,9 URB 00 D08L 020

T330274

1

6,9 URB 00 D08L 025

M330268

1

6,9 URB 00 D08L 032

N330269

1

6,9 gRB 00 D08L 016

S330273

1

6,9 gRB 00 D08L 020

S330227

1

6,9 URB 00 D08L 040

P330270

1

6,9 gRB 00 D08L 025

T330228

1

6,9 URB 00 D08L 050

Q330271

1

6,9 gRB 00 D08L 032

V330229

1

6,9 gRB 00 D08L 040

W330230

1

6,9 gRB 00 D08L 050

X330231

1

6,9 gRB 00 D08L 063

Y330232

1

6,9 gRB 00 D08L 080

Z330233

1

6,9 gRB 00 D08L 100

A330234

1

6,9 gRB 00 D08L 125

B330235

0.9

6,9 gRB 00 D08L 160

C330236

0.9

URB
DIN 80

German Standard According to
DIN 43653/00C - DIN 80 & 110

gRB
DIN 110

Weight : 140 g(D08) - 190 g(D11)
Packaging : 3 pieces
Microswitches:	
MS 4L 2.5 B6 - Part #: L076646
	
6.3 clips or MC 4L 2.5 B6 + PRES - Part #: F210156
	
MS 4L 2.5 B2 - Part #: G076642
	
2.8 clips or MC 4L 2.5 B2 + PRES - Part #: G210157
Fuse-base: SI 00 DIN 80 - Part #: Q098040

URB
DIN 110

gRB
DIN 43620

Fuse-base: 41002-G

R330272

1

D330237

1

6,9 URB 00 D08L 100

E330238

1

6,9 URB 00 D08L 125

F330239

0.9

6,9 URB 00 D08L 160

G330240

0.85

6,9 URB 00 D08L 200

H330241

0.85

6,9 URB 00 D08L 250

J330242

0.80

6,9 URB 00 D08L 315

K330243

0.75

6,9 URB 00 D08L 350

L330244

0.75

6,9 URB 00 D08L 400

M330245

0.70

6 URB 00 D08L 450

N330246

0.65

6,9 gRB 00 D11L 016

W330276

1

6,9 gRB 00 D11L 020

P330247

1

6,9 gRB 00 D11L 025

Q330248

1

6,9 gRB 00 D11L 032

R330249

1

6,9 gRB 00 D11L 040

S330250

1

6,9 gRB 00 D11L 050

T330251

1

6,9 gRB 00 D11L 063

V330252

1

6,9 gRB 00 D11L 080

W330253

1

6,9 gRB 00 D11L 100

X330254

1

6,9 gRB 00 D11L 125

Y330255

0.9

6,9 gRB 00 D11L 160

Z330256

0.9

6,9 URB 00 D11L 80

A330257

1

6,9 URB 00 D11L 100

B330258

1

6,9 URB 00 D11L 125

C330259

0.9

6,9 URB 00 D11L 160

D330260

0.85

6,9 URB 00 D11L 200

E330261

0.85

6,9 URB 00 D11L 250

F330262

0.80

6,9 URB 00 D11L 315

G330263

0.75

6,9 URB 00 D11L 350

H330264

0.75

6,9 URB 00 D11L 400

J330265

0.70

6 URB 00 D11L 450

K330266

0.65

Description

German Standard According to
DIN 43620/00

Weight : 210 g
Packaging : 3 pieces
Microswitches:	
6.3 clips or MC 4L 2.5 B6 + PRES - Part #: F210156
	
	
2.8 clips or MC 4L 2.5 B2 + PRES - Part #: G210157

6,9 URB 00 D08L 063
6,9 URB 00 D08L 080

URD
DIN 43620

I/N Fuse

Cat. No.

Base*

6,9 gRB 00 PV/016

L330267

1

6,9 gRB 00 PV/020

W330207

1

6,9 gRB 00 PV/025

X330208

1

6,9 gRB 00 PV/032

Y330209

1

6,9 gRB 00 PV/040

Z330210

1

6,9 gRB 00 PV/050

A330211

1

6,9 gRB 00 PV/063

B330212

0.90

6,9 gRB 00 PV/080

C330213

0.90

6,9 gRB 00 PV/100

D330214

0.90

6,9 gRB 00 PV/125

E330215

0.85

6,9 gRB 00 PV/160

F330216

0.85

6,9 URD 00 PV0080

Z320159

0.90

6,9 URD 00 PV0100

D320163

0.90

6,9 URD 00 PV0125

F320165

0.85

6,9 URD 00 PV0160

K320169

0.85

6,9 URD 00 PV0200

M320171

0.85

6,9 URD 00 PV0250

R320175

0.80

6,9 URD 00 PV0315

W320179

0.75

I/IN : Ratio RMS steady current / current rating for fuses in base.

D34

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

URE/URGS/URZ British Standard
Protistor® Fuses
250V AC
URE/URGS/URZ from 5 up to 180A
Sizes: 10 X 28 - 17 X 27 mm
Features/Benefits:
•• Extremely high interrupting rating
•• Protection of power semiconductors according to 	 IEC 269.1 and 4

D

•• 250V according to IEC 33
•• aR class (ratings from 5 to 32A) according to VDE 636-23 and IEC 269.4
•• Model according to NF C 63210 and 63211 with built-in blown trip-indicator
•• 17X27 are UL recognized

Applications Data
Voltage
Rating

Size

Class

UN (V)

10x28

URE

250 V
URGS

17x27

URZ

Ratings:
Current

Melting I2t @

Rating

1 ms

IN (A)

I2tP (A2s)

Total Clearing
I2t @ UN I2t t
(A 2s)

Watts Loss
0.8 IN

IN

Volts	

Tested

: 250VAC

Amps	 : 5 to 180A

Interrupting

IR	

Rating

: 160kA I.R.

5

1.3

10

11

0.6

1

6

1.8

13

15

0.7

1.2

10

2.4

18

20

1.2

2.1

12

4.3

28

33

1.6

2.8

15

6.7

41

48

2.0

3.5

20

15.0

85

100

2.2

4.0

25

27.0

135

160

2.6

4.7

32

53.0

240

280

3.0

5.4

7

1.3

8.5

9.8

0.56

1

10

4.5

21

23.8

0.84

1.5

12

5.9

27

31

1.1

2.0

16

11.2

50

59

1.7

3.0

20

15.6

80

100

2.2

3.9

25

30.0

130

160

2.7

4.8

30

45.0

195

235

3.2

5.6

•• IEC 269.4, VDE 636.23 (5-32A)

35

63.0

270

330

3.7

6.5

50

180.0

790

940

4.9

8.8

•• IEC 33 (250V)

60

250.0

1100

1310

5.8

10.4

75

380.0

1670

1990

7.2

13.6

80

480.0

2100

2530

7.25

13.7

100

730.0

3350

4060

6.5

11.5

125

850.0

5720

6920

6.7

12.3

150

1250.0

7930

9590

7.4

13.6

160

1730.0

9600

11700

8.8

15.6

180

2090.0

14500

17500

9.5

17

Approvals
160 kA @ 250 V

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

•• UL Recognized Component
(17x27mm)

www.barr-thorp.com

D35

URE/URGS/URZ British Standard
Catalog Numbers
Size

10x28 mm

Size

17x27 mm

Size

17x27 mm

D36

Description

Catalog No.

2.5 URE 10/5

M082489

2.5 URE 10/6

E097478

2.5 URE 10/10

I082488

2.5 URE 10/12

P097487

2.5 URE 10/15

K082487

2.5 URE 10/20

J082486

2.5 URE 10/25

X097494

2.5 URE 10/32

N081984

Description

Catalog No.

2.5 URGS 17/7

M076647

2.5 URGS 17/10

N076648

2.5 URGS 17/12

P076649

2.5 URGS 17/16

Q076650

2.5 URGS 17/20

L09507

2.5 URGS 17/25

R076651

2.5 URGS 17/30

S076652

2.5 URGS 17/35

T076653

2.5 URGS 17/50

V076654

2.5 URGS 17/60

W076655

2.5 URGS 17/75

X076656

2.5 URGS 17/80

Z085559

2.5 URGS 17/100

Y085558

2.5 URGS 17/125

G097526

2.5 URGS 17/150

W085556

2.5 URGS 17/160

F097527

2.5 URGS 17/180

N097532

Description

Catalog No.

2.5 URGS 17 P7

P097533

2.5 URGS 17 P10

Q097434

2.5 URGS 17 P12

S097536

2.5 URGS 17 P16

X097540

2.5 URGS 17 P20

B097540

2.5 URGS 17 P25

D097546

2.5 URGS 17 P30

E097547

2.5 URGS 17 P35

F097548

2.5 URGS 17 P50

J097551

2.5 URGS 17 P60

H081082

2.5 URGS 17 P75

K097552

2.5 URGS 17 P80

L097553

2.5 URZ 17 P100

P097556

2.5 URZ 17 P125

Q097557

2.5 URZ 17 P150

R097558

2.5 URZ 17 P160

S097559

2.5 URZ 17 P180

T097560

10x28 without Trip-Indicator (mm)

17x27 without Trip-Indicator (mm)

17x27 with Separated Trip-Indicator (mm)

Microswitch MC 6.3 GR 2.5N

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

URGG/URGH British Standard
Protistor® Fuses
250V
URGG/URGH from 50 to 1050A
SizeS: 36 X 27 - 2 X 36 x 27 mm
Features/Benefits:
•• Extremely high-Interrupting rating fuses
•• Protection of power semiconductors according to IEC 269.1 and 4

D

•• aR class (ratings from 50 to 525A URGG - 300 to 1050A URGH)
according to IEC 269.4
•• Complies with BS 88-4		
- without indicator				
- with external trip-indicator

Ratings:

Applications Data
Voltage
Rating

Size

Class

UN (V)

36x27

URGG

250 V

2x36x27

URGH

Volts	
Current

Melting I2t

Rating

@ 1 ms

IN (A)

I2tP (A2s)

50

120

75

330

100

Total
Clearing
I2t @ UN

Watts Loss
0.8 IN

IN

500

4.75

9.5

1380

6.3

12.6

745

3060

7.8

15.7

125

1340

5500

9.1

18.2

150

1930

7950

10.8

21.6

200

4020

16400

13.5

27.0

250

5350

30000

16.3

32.6

300

7290

49600

18.6

37.2

350

18000

74000

21

42.0

400

25100

128000

23.4

46.7

450

33500

170000

27.1

54.1

500

43000

219000

30.4

60.8

525

48200

245000

33.2

66.4

300

7700

31800

21.6

43.2

350

11500

48700

24.3

48.6

400

16000

65600

27

54.0

500

29100

120000

32.6

65.2

600

48200

198500

37.2

74.4

700

72000

276000

42.0

84.0

800

100000

512000

46.7

93.4

900

134000

680000

54.1

108.2

1000

172000

876000

60.8

121.6

1050

193000

980000

66.4

132.8

I t t (A s)
2

2

: 250VAC

Amps	 : 50 to 1050A

Tested

IR	

Interrupting

: 100kA I.R

Rating

Approvals
100 kA @ 250 V

•• IEC 269.4
•• URGG (50-525A)
•• URGH (300-1050A)
•• BS 88-4
•• URGG (50-525A)
•• URGH (300-1050A)

Minimum operating voltage for all trip indicators = 20V

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D37

URGG/URGH British Standard
Size

36x27mm

Size

36x27mm

Size

36x27mm

Size

2X36x27mm

Size

2X36x27mm

D38

Description

Catalog No.

2.5 URGG 36/50

J080945

2.5 URGG 36/75

K080946

2.5 URGG 36/100

L080947

2.5 URGG 36/125

R082470

2.5 URGG 36/150

Q082469

2.5 URGG 36/200

P082468

2.5 URGG 36/250

N082467

2.5 URGG 36/300

M082466

2.5 URGG 36/350

L082465

2.5 URGG 36/400

G075538

2.5 URGG 36/450

H075539

2.5 URGG 36/500

J075540

2.5 URGG 36/525

K075541

Description

Catalog No.

2.5 URGG36T50

F080942

2.5 URGG36T75

G080943

2.5 URGG36T100

H080944

2.5 URGG36T125

W082382

2.5 URGG36T150

V080944

2.5 URGG36T200

T082380

2.5 URGG36T250

S082379

2.5 URGG36T300

R082378

2.5 URGG36T350

Q082377

2.5 URGG36T400

L075542

2.5 URGG36T450

M075542

2.5 URGG36T500

N075544

2.5 URGG36T525

P075545

36x27 - without Trip-Indicator (mm)

36x27 - with Built-in Trip-Indicator (mm)

Microswitch MC 36 GR 2.5 N Ref. P 092496

36x27 - with Separated Trip-Indicator (mm)

Description

Catalog No.

2.5 URGG36P50

C090939

2.5 URGG36P75

D080940

2.5 URGG36P100

E080941

2.5 URGG36P125

Y081004

2.5 URGG36P150

X081003

Microswitch MC 6.3 GR 2.5 N -

2.5 URGG36P200

W081002

Ref. Y 310005

2.5 URGG36P250

V081001

2.5 URGG36P300

T081000

2.5 URGG36P350

S080999

2.5 URGG36P400

V075504

2.5 URGG36P450

W07550

2.5 URGG36P500

X075506

2.5 URGG36P525

Y075507

Description

Catalog No.

2.5 URGH236/300

K082464

2.5 URGH236/350

J082463

2.5 URGH236/400

H082462

2.5 URGH236/500

G082461

2.5 URGH236/600

F082460

2.5 URGH236/700

E082459

2.5 URGH236/800

Q075546

2.5 URGH236/900

R075547

2.5 URGH236/1000

S075548

2.5 URGH236/1050

T075549

Description

Catalog No.

2.5 URGH236T300

P082376

2.5 URGH236T350

N082375

2.5 URGH236T400

M082374

2.5 URGH236T500

L082373

2.5 URGH236T600

K082372

2.5 URGH236T700

J082371

2.5 URGH236T800

V075550

2.5 URGH236T900

R075501

2.5 URGH236T1000

S075502

2.5 URGH236T1050

T075503

2x36x27 - without Trip-Indicator (mm)

2x36x27 - with Built-in Trip-Indicator (mm)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Microswitch MC 36 GR 2.5 N Ref. P 092496

www.barr-thorp.com

URE/URS/URT British Standard
Protistor® Fuses
690V
URE/URS/URT from 5 to 160A
Sizes: 10 X 51 - 17 X 49 - 2 x 17 x49 mm
Features/Benefits:
•• Extremely high Interrupting rating fuses
•• Protection of power semiconductors according to IEC 269.1 and 4

D

•• aR class (ratings from 5 to 160A) according to IEC 269.4
•• Two models complying with BS 88-4		
- without indicator (17X49mm)			
- with external trip-indicator (2x17x49mm)

Applications Data
Voltage
Rating
UN (V)

Size
mm

10x51

17x49

Class

URE

URS

690 V

2x17x49

URT

Current

Melting I2t @

Rating

1 ms

IN (A)

I2tP (A2s)

Total Clearing
I2t @ UN
I2t t (A 2s)

Watts Loss
0.8 IN

IN

5

1.3

10

15

1.05

2

6

1.3

13.5

20.5

1.3

2.5

10

3.3

25

35

2.2

4.1

12

5.5

40

58

2.3

4.3

15

9.7

70

100

2.4

4.4

20

19.4

120

200

3.1

5.8

16

9.7

75

107

2.7

4.8

20

17.3

130

185

2.9

5.3

25

27

200

285

3.7

6.7

32

53

400

570

4.7

8.6

35

70

510

725

5.2

9.6

40

98

760

1080

5.7

10.5

45

130

900

1280

6.2

11.4

50

156

1000

1420

6.8

12.6

55

210

1380

1970

7.2

13.3

63

315

2000

2850

7.5

13.9

75

525

3350

4630

7.8

14.4

80

625

3900

5700

8.5

15.8

65

210

1590

2270

9.5

17.4

75

310

2300

3280

10.9

20

85

430

3050

4350

11.9

21.9

90

525

3600

5130

12.4

22.8

110

850

5500

7840

13.8

26.5

140

1730

11000

15700

15.5

28.5

150

2090

13400

18500

15.6

28.7

160

2500

15600

22800

16.9

31.5

Tested
Interrupting
Rating

200 kA
@ 690 V

Minimum operating voltage for all trip indicators = 20V

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D39

URE/URS/URT British Standard
Size

10x51mm

Size

17x49mm

Size

17x49mm

Size

2X17x49mm

Size

2X17x49mm

D40

Description

Catalog No.

6,9 URE 10/5

D 082458

6,9 URE 10/6

X 097057

6,9 URE 10/10

C 082457

6,9 URE 10/12

Z 079059

6,9 URE 10/15

B 082456

6,9 URE 10/20

A 082456

Description

Catalog No.

6,9 URS 17/16

G 075883

6,9 URS 17/20

H 075884

6,9 URS 17/25

J 075885

6,9 URS 17/32

K 075886

6,9 URS 17/35

L 075887

6,9 URS 17/40

M 075888

6,9 URS 17/45

N 075889

6,9 URS 17/50

P 075890

6,9 URS 17/55

Q 075891

6,9 URS 17/63

R 075892

6,9 URS 17/75

S 075893

6,9 URS 17/80

T 075894

Description

Catalog No.

6,9 URS 17 P 16

V 075895

6,9 URS 17 P 20

W 075896

6,9 URS 17 P 25

X 075897

6,9 URS 17 P 32

Y 075898

6,9 URS 17 P 35

Z 075899

6,9 URS 17 P 40

A 075900

6,9 URS 17 P 45

B 075901

6,9 URS 17 P 50

K 081084

6,9 URS 17 P 55

C 075902

6,9 URS 17 P 63

D 075903

6,9 URS 17 P 75

E 075904

6,9 URS 17 P 80

F 075905

Description

17x49 - without Trip-Indicator (mm)

17x49 - with Separate Trip-Indicator (mm)

2x17x49 - without Trip-Indicator (mm)

Catalog No.

6,9 URT 217/65

G 075906

6,9 URT 217/75

F 099572

6,9 URT 217/85

H 075907

6,9 URT 217/90

A 099958

6,9 URT 217/110

B 099959

6,9 URT 217/140

J 075908

6,9 URT 217/150

C 099960

6,9 URT 217/160

K 075909

Description

10x51 - without Trip-Indicator (mm)

2x17x49 - with Separate Trip-Indicator (mm)
Microswitch MC6,3
GR 2-5N : Reference
Number Y310015

Catalog No.

6,9 URT 217 P 65

L 075910

6,9 URT 217 P 75

M 075911

6,9 URT 217 P 85

M 075912

6,9 URT 217 P 90

P 075913

6,9 URT 217 P 110

Q 075914

6,9 URT 217 P 140

R 075915

6,9 URT 217 P 150

S 075916

6,9 URT 217 P 160

T 075917

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

URR/URGL/URU/URGM British Standard
Protistor® fuses
690V
URR/URGL/URU/URGM from 75 to 800A
Sizes: 36 X 55 & 2 X 36 x 55 mm
Features/Benefits:
•• Extremely high Interrupting rating fuses
•• Protection of power semiconductors according to IEC 269.1 and 4

D

•• aR class ratings from 75 to 800A according to IEC 269.4
•• Complies with BS 88-4		
- without indicator				
- with external trip-indicator			
- with built in trip-indicator

Applications Data
Voltage
Rating
UN (V)

Size
mm

Class

URR

36x55
URGL

690 V

URU

2x36x55

URGM

Current

Melting I2t @

Rating

1 ms

IN (A)

I2tP (A2s)

75

350

Total Clearing
I2t @ UN
I2t t (A 2s)

1800

2000

Watts Loss
0.8 IN

IN

9.7

19.5

110

1180

6000

6700

11.3

22.8

200

3900

18500

20500

21.8

41.4

250

8760

41000

46000

23.6

44.1

50

180

860

990

7.3

14.0

65

335

1600

1840

8.8

17.1

85

480

3450

4000

12.2

23.5

90

720

4100

4700

13.2

25.5

150

2880

12600

14500

18.9

35.3

180

5350

22500

25500

19.1

35.7

200

9510

40000

46000

17.7

33.1

250

21400

97000

110000

18.7

34.5

280

29100

125000

145000

20.3

38.0

Tested
Interrupting
Rating

315

38100

157000

180000

22.7

42.6

355

48200

190000

215000

25.9

48.5

200 kA

400

72000

265000

305000

26.7

50.0

@ 690 V

200

4700

24000

27000

18.4

33.0

235

6920

34500

39000

21.0

37.6

400

21200

100000

110000

34.8

62.3

500

35000

164000

184000

47.2

88.2

630

97300

515000

575000

41.1

73.2

175

2880

13800

16000

24.7

47.6

300

13700

60000

68000

31.5

59.0

325

21400

90000

102000

30.0

54.0

355

25200

106000

120000

33.1

62.0

450

65600

300000

340000

34.6

63.8

500

85600

390000

440000

37.4

69.0

630

15200

630000

720000

45.4

85.2

710

193000

760000

860000

51.8

97.0

800

282000

1.06 106

1.22 106

53.4

100.0

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D41

URR/URGL/URU/URGM British Standard
Size

36x55mm

Description

Catalog No.

6,9 URGL36/50

X097103

6,9 URGL36/65

H097113

6,9 URGL36/75

H097136

6,9 URGL36/85

M097163

6,9 URGL36/90

N097164

6,9 URGL36/110

P097165

6,9 URGL36/150

Q097167

6,9 URGL36/180

S097168

6,9 URR36/200

T097169

6,9 URGL36/200

V097170

6,9 URR36/250

W097171

6,9 URGL36/280

A097175

6,9 URGL36/315

B097176

6,9 URGL36/355

C097177

6,9 URGL36/400

D097178

Description

Catalog No.

6,9 URGL36T50

N097210

6,9 URGL36T65

K097210

6,9 URGL36T75

H099965

6,9 URGL36T85

M097255

6,9 URGL36T90

N097256

6,9 URGL36T110

R099973

6,9 URGL36T150

Z082178

6,9 URGL36T180

P097257

6,9 URR36T200

A085560

6,9 URGL36T200

R097259

6,9 URR36T250

W097263

6,9 URGL36T250

X097266

6,9 URGL36T280

Y097266

6,9 URGL36T315

Z097266

6,9 URGL36T355

A097267

6,9 URGL36T400

C097269

36x55 - without Trip-Indicator (mm)

36x55 - with Built-in Trip-Indicator (mm)
Size

36X55mm

Size

36X55mm

D42

Description

Catalog No.

6,9 URGL36P90

H097182

6,9 URR36P110

J097183

6,9 URGL36P150

K097184

6,9 URGL36P180

L097185

6,9 URR36P200

M097186

6,9 URGL36P200

N097187

6,9 URR36P250

P097188

6,9 URGL36P250

Q097189

6,9 URGL36P280

R097190

6,9 URGL36P315

V097193

6,9 URGL36P355

Y097196

6,9 URGL36P400

M097209

Microswitch MC 36 GR 2.5 N Ref. P 092496

36x55 - with Separated Trip-Indicator (mm)

Microswitch MC 6.3 GR 2.5 N Ref. Y 310015

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

URR/URGL/URU/URGM British Standard

2X36x55mm

Size

2X36x55mm

Description

Catalog No.

6,9 URGM236/175

D097270

6,9 URU236/200

F097272

6,9 URU236/235

J097275

6,9 URGM236/300

K097276

6,9 URGM236/325

R097282

6,9 URGM236/355

S097283

6,9 URU236/400

T097284

6,9 URGM236/450

Y097288

6,9 URGM236/500

Z097289

6,9 URU236/500

A097290

6,9 URGM236/630

B097291

6,9 URU236/630

R097351

6,9 URGM236/710

S097352

6,9 URGM236/800

Y097357

Description

Catalog No.

6,9 URGM236T175

F097456

6,9 URU236T200

G097457

6,9 URU236T235

A082179

6,9 URGM236T300

S085553

6,9 URGM236T325

J097463

6,9 URGM236T355

N097463

6,9 URU236T400

P097464

6,9 URGM236T450

Q097465

6,9 URGM236T500

R097466

6,9 URU236T500

S097470

6,9 URGM236T630

V097469

6,9 URU236T630

W097470

6,9 URGM236T710

C097476

6,9 URGM236T800

D097477

2x36x55 - without Trip-Indicator (mm)

D

Size

2x36x55 - with Built-in Trip-Indicator (mm)

Microswitch MC 36 GR 2.5 N - Ref. P 092496

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D43

690/700 Volt PSC Square Body
Mersen 690/700V PSC fuse-links provide maximum flexibility in equipment design
and ultimate protection for today’s power conversion equipment. These square body
fuse-links are available in four different body sizes, each size having seven worldwide
acceptable mounting styles. The different mounting styles and body sizes along with
a broad range of ampere ratings allow greatest flexibility in equipment design.
Mersen PSC fuses have been engineered to provide state-of-the-art protection for
SCR’s, diodes, thyristors, GTO’s and IGBT devices. They have pure silver, die-cut
elements embedded in solidified sand, which helps control arcing characteristics
for low I2t and high interrupting rating. All contact surfaces are silver plated and all
hardware is non-magnetic.
All fuse links are equipped with a low voltage trip-indicator. This trip-indicator can
operate a field mountable microswitch which is easily mounted directly onto the fuse
even while in service.

Ratings:
Volts	

: 500-700 VAC

	

: DC - consult factory

Amps	 : 40-2500A

Features/Benefits:

I.R.	

•• Choice of mounting styles gives wide choice for equipment design

: 200kA I.R.

•• Broad range of ampere ratings in a given body size for design flexibility
•• IEC 269-4 compliance for worldwide semiconductor applications 		
* For Microswitch information see page J7

Approvals:
•• UL recognized	component

Highlights:

Applications:

•• Extremely fast-acting 	

•• Protection of rectifiers, inverters,

•• Current-limiting

File E76491
•• Sizes 30, 31 ,32, 33 tested to

DC drives,

•• Very low I t

IEC 269.4

•• UPS Systems, reduced voltage

2

•• Worldwide acceptability superior
cycling ability

motor starters, and other
equipment in globally accepted
applications

Part Number Designation:
6,9 URD: 	

European/IEC

		

Mounting Style/Approval

		

Tested @ 1.1 Vn

AO7O URD:	 North American
		

Mounting Style/Approval

		

Tested @ Vn	

*Vn = rated voltage

D44

N.
		American Reference Numbering System
A	 070	 URD	 31	

I	 350

A.C.				
	
	Rated Volts
(070=700V)	

	
Class
Size	

	
Mounting Types	

European
Reference Numbering System
		

30
31
32
33

Straight-blade, short	 KI
	Straight-blade, long
LI
	Flat-type, one hole
TTI
(American)			

6.9	URD	 31	

				
	
	Rated Volts
(6,9=690V)	

	
Class
Size	

	
Mounting Types	
DIN 80	
DIN 110

DO8A
D11A
	Flat-type, one hole (metric) TTF
French Blade			
EF

Indicator

Indicator

Amp Rating

Amp Rating

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

30
31
32
33

www.barr-thorp.com

I	 350

690/700 Volt PSC Square Body
European Blade, Type DO8A
Body
Size
30
31
32

Outline Dimensions

Dimensions - mm

Type

D08

33

Types D08A and D11A

A

B

C

D

E

F

G

40

25

12.5

21

17

77

110

51

25

12.5

25

22.5

77

110

60

32

16

30

27

77

110

74.5

40

20

37.2

34.25

77

110

10.5

10.5

European Blade, Type D11A
Body
Size

47.6
H

Dimensions - mm

Type

A

B

C

D

E

F

G

40

25

12.5

21

17

101.6

134.6

31

51

25

12.5

25.5

22.5

101.6

134.6

D11

33

F
G

30
32

B

D

C

60

32

16

30

27

101.6

134.6

74.5

40

20

37.2

34.25

101.6

134.6

4.7

A
D

E

6
A

North American Straight Blade, Type KI
Body
Size

Type

30
31
32

KI

33

Types KI and LI

Dimensions - mm / in
A

B

C

D

E

F

G

H

J

40

25

12.5

21

18

68

107

129

10.5

(1.57)

(.98)

(.49)

(.83)

(.71)

(2.68)

(4.21)

(5.08)

(.41)

.51

25

12.5

25.5

22.5

67.6

107.1

128.8

14.3

60

32

16

30

27

74.2

109

134

14.6

(2.36)

(1.26)

(.63)

(1.18)

(1.06)

2.92)

(4.29)

(5.28)

(.57)

74.5

40

20

37.2

34.2

75.4

107.6

134

15.9

(2.93)

(1.57)

(.79)

(1.46)

(1.35

(2.97)

(4.24)

(5.28)

(.63)

J

C

B

47.6
1.93
F
G
H

North American Straight Blade, Type LI
Body
Size

Type

30
31
32
33

LI

Dimensions - mm /in

A

A

B

C

D

E

F

G

H

J

40

25

12.5

21

18

87.6

126.6

148.6

10.5

(1.57)

(.98)

(.49)

(.83)

(.71)

(3.45)

(4.98)

(5.85)

(.41)

51

25

12.5

25.5

22.5

91.6

122.4

148.6

14.6

(2.01)

(.98)

(.49)

(1.00)

(.89)

(3.61)

(4.82)

(5.85)

(.57)

60

32

16

30

27

94.2

129

153

14.6

(2.36)

(1.26)

(.63)

(1.18)

(1.06)

(3.71)

(5.08)

(6.02)

(.57)

74.5

40

20

37.2

34.2

94.4

126.6

153

15.9

(2.93)

(1.57)

(.79)

(1.46)

(1.35)

(3.72)

(4.98)

(6.02)

(.63)

D

6
(.24)
4.7

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

E

www.barr-thorp.com

D45

690/700 Volt PSC Square Body
Outline Dimensions

North American Flat Single Hole, Type TTI
Body Size

Types TTI and TTF

Dimensions - mm / in

Type

30
31
TTI
32

33

A

B

1.57

1.00

(40)

(25)

2.00

1.19

(50.8)

(30.2)

2.37

1.50

(60.3)

(38.1)

2.94

1.81

(74.6)

(46)

C
5/16-18 x .35
5/16-18 x .35
3/8-16 x .35

1/2-13 x .35

European Flat Single Hole, Type TTF
Body
Size

Type

Dimensions - mm
A

B

C

30

40

26

M8 x 1.25 x 6 DP

31

51

30

M8 x 1.25 x 9 DP

60

38

M10 x 1.50 x 9 DP

74.5

46

M12 x 1.75 x 9 DP

32

TTF

33

Standard Threaded Studs
Size
30 & 31

Ref. and Dimension Per Pair
of Studs

Torque (Nm)*

Mounting

(g)

S 98 801 (HC M8 X 30 & M 8 X 35)

Max Nut Tightening

Max Stud

Weight

Torque (Nm)

23

10

Fig. 1

Fig. 2

Fig. 3

13.5

13.5

13.5

32

T 98 802 (HC M 10 X 30 & M 10 X 50)

40

26

26

26

33

V 98 803 (HC M 12 X 35 & M 12 X 50)

60

46

46

46

2X32

W 98 804 (HC M 10 X 50)

50

26

26

26

2X33

X 98 805 (HC M 12 X 50)

70

46

46

46

15

*in.lbs = Nm/.113

Type EF
European French Blade, Type EF
Body
Size

Type

D

B

C

D

E

F

30

40

18

11

9

100

76.6

31

50

25

16

10.5

110

86.5

59

32

21.2

13

13

90.8

74.5

40

19.5

13

13

91

33

EF

6

Dimensions - mm
A

32

47.6 MAX

C

B

A

F
E

D46

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

62

www.barr-thorp.com

690/700 Volt PSC Square Body
Body Size

30

31

32

33

Total I²t

** Watts Loss

@ 660VAC

@ Rated

(A²s x 10³)

Current (W)

0.116

0.68

0.2

1.09

690

0.33

100

690

125

Amp

Rated

Melting I²t

Rating

Voltage

(A²s x 10³)

50

690

63

690

80

Catalog No

New Description

Old Description

9

G301191

PC30UD69V50D1A

6,9URD30D11A0050

14

Q300118

PC30UD69V63D1A

6,9URD30D11A0063

1.75

19

R300119

PC30UD69V80D1A

6,9URD30D11A0080

0.47

2.5

26

S300120

PC30UD69V100D1A

6,9URD30D11A0100

690

0.85

4.5

30

T300121

PC30UD69V125D1A

6,9URD30D11A0125

160

690

1.6

8.5

37

V300122

PC30UD69V160D1A

6,9URD30D11A0160

200

690

3

15.5

42/43

W300123

PC30UD69V200D1A

6,9URD30D11A0200

250

690

5.8

30

48/50

X300124

PC30UD69V250D1A

6,9URD30D11A0250

315

690

12

62

53/55

Y300125

PC30UD69V315D1A

6,9URD30D11A0315

350

690

15.5

80

57/60

Z300126

PC30UD69V350D1A

6,9URD30D11A0350

400

690

23

120

60/65

A300127

PC30UD69V400D1A

6,9URD30D11A0400

450

660

26

153

80/88

S300695

PC30UD69V450D1A

6,9URD30D11A0450

500

660

41

245

80/88

Y301091

PC30UD69V500D1A

6,9URD30D11A0500

550

660

52

305

80/90

Z301092

PC30UD69V550D1A

6,9URD30D11A0550

200

690

2.6

14

45

H300019

PC31UD69V200D1A

6,9URD31D11A0200

250

690

4.7

25

52

J300020

PC31UD69V250D1A

6,9URD31D11A0250

315

690

7.5

40

65

K300021

PC31UD69V315D1A

6,9URD31D11A0315

350

690

10.5

55

67

P300048

PC31UD69V350D1A

6,9URD31D11A0350

400

690

19

100

68

L300022

PC31UD69V400D1A

6,9URD31D11A0400

450

690

26.5

140

70

M300023

PC31UD69V450D1A

6,9URD31D11A0450

500

690

37

195

70/72

N300024

PC31UD69V500D1A

6,9URD31D11A0500

550

690

52

280

70/75

P300025

PC31UD69V550D1A

6,9URD31D11A0550

630

690

75

390

75/85

Q300026

PC31UD69V630D1A

6,9URD31D11A0630

700

690

95

490

85/95

R300027

PC31UD69V700D1A

6,9URD31D11A0700

800

660

140

815

105/120

H300709

PC31UD69V800D1A

6,9URD31D11A0800

400

690

15

80

72/75

P300186

PC32UD69V400D1A

6,9URD32D11A0400

450

690

22

115

77/80

Q300187

PC32UD69V450D1A

6,9URD32D11A0450

500

690

28

145

85/90

R300188

PC32UD69V500D1A

6,9URD32D11A0500

550

690

37

195

90/95

S300189

PC32UD69V550D1A

6,9URD32D11A0550

630

690

54

280

95/105

T300190

PC32UD69V630D1A

6,9URD32D11A0630

700

690

76

400

100/110

V300191

PC32UD69V700D1A

6,9URD32D11A0700

800

690

115

600

110/120

W300192

PC32UD69V800D1A

6,9URD32D11A0800

900

660

170

900

110/125

X300193

PC32UD69V900D1A

6,9URD32D11A0900

1000

660

240

1250

115/135

Y300194

PC32UD69V10CD1A

6,9URD32D11A1000

500

690

19

100

105

S300258

PC33UD69V500D1A

6,9URD33D11A0500

550

690

27

140

105/110

T300259

PC33UD69V550D1A

6,9URD33D11A0550

630

690

40

130

110/120

V300260

PC33UD69V630D1A

6,9URD33D11A0630

700

690

55

300

115/125

W300261

PC33UD69V700D1A

6,9URD33D11A0700

800

690

95

490

120/130

X300262

PC33UD69V800D1A

6,9URD33D11A0800

900

690

135

700

120/135

Y300263

PC33UD69V900D1A

6,9URD33D11A0900

1000

690

170

900

135/155

Z300264

PC33UD69V10CD1A

6,9URD33D11A1000

1100

690

240

1260

135/160

A300265

PC33UD69V11CD1A

6,9URD33D11A1100

1250

660

350

1850

150/180

B30026

PC33UD66V11CD1A

6,6URD33D11A1250

1400

660

480

2500

160/200

C300267

PC33UD69V14CD1A

6,9URD33D11A1400

1500

600

500

220

H301974

PC33UD60V15CD1A

6URD33D11A1500

1600

600

555

210/240

Z301437

PC33UD60V16CD1A

6URD33D11A1600

D

690 Volt European/IEC Style Ratings and Application Data, D11A Mounting

** Watts loss data is published for both blade and tapped style mounting configurations. When two watts loss values are shown this represents tapped/blade
values respectively.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D47

690/700 Volt PSC Square Body
690 Volt European/IEC Style Ratings and Application Data, D08A Mounting
Body Size

30

31

32

33

Amp

Rated

Melting I²t

Rating

Voltage

(A²s x 10³)

50

690

63

690

80

Total I²t

@

** Watts Loss @

Catalog No

New Description

Old Description

9

F301926

PC30UD69V50A

6,9URD30D08A0050

14

E300108

PC30UD69V63A

6,9URD30D08A0063

1.75

19

F300109

PC30UD69V80A

6,9URD30D08A0080

0.47

2.5

26

S300120

PC30UD69V100D1A

6,9URD30D11A0100

690

0.85

4.5

30

H300111

PC30UD69V125A

6,9URD30D08A0125

160

690

1.6

8.5

37

J300112

PC30UD69V160A

6,9URD30D08A0160

200

690

3

15.5

42/43

K300113

PC30UD69V200A

6,9URD30D08A0200

250

690

5.8

30

48/50

L300114

PC30UD69V250A

6,9URD30D08A0250

315

690

12

62

53/55

M300115

PC30UD69V315A

6,9URD30D08A0315

350

690

15.5

80

57/60

N300116

PC30UD69V350A

6,9URD30D08A0350

400

690

23

120

60/65

P300117

PC30UD69V400A

6,9URD30D08A0400

450

660

26

153

80/88

A300403

PC30UD69V450A

6,9URD30D08A0450

500

660

41

245

80/88

B300404

PC30UD69V500A

6,9URD30D08A0500

550

660

52

305

80/90

C300405

PC30UD69V550A

6,9URD30D08A0550

200

690

2.6

14

45

Y300010

PC31UD69V200A

6,9URD31D08A0200

250

690

4.7

25

52

Z300011

PC31UD69V250A

6,9URD31D08A0250

315

690

7.5

40

65

A300012

PC31UD69V315A

6,9URD31D08A0315

350

690

10.5

55

67

Q300049

PC31UD69V350A

6,9URD31D08A0350

400

690

19

100

68

B300013

PC31UD69V400A

6,9URD31D08A0400

450

690

26.5

140

70

C300014

PC31UD69V450A

6,9URD31D08A0450

500

690

37

195

70/72

D300015

PC31UD69V500A

6,9URD31D08A0500

550

690

52

280

70/75

E300016

PC31UD69V550A

6,9URD31D08A0550

630

690

75

390

75/85

F300017

PC31UD69V630A

6,9URD31D08A0630

700

690

95

490

85/95

G300018

PC31UD69V700A

6,9URD31D08A0700

800

660

140

815

105/120

D300406

PC31UD69V800A

6,9URD31D08A0800

400

690

15

80

72/75

E300177

PC32UD69V400A

6,9URD32D08A0400

450

690

22

115

77/80

F300178

PC32UD69V450A

6,9URD32D08A0450

500

690

28

145

85/90

G300179

PC32UD69V500A

6,9URD32D08A0500

550

690

37

195

90/95

H300180

PC32UD69V550A

6,9URD32D08A0550

630

690

54

280

95/105

J300181

PC32UD69V630A

6,9URD32D08A0630

700

690

76

400

100/110

K300182

PC32UD69V700A

6,9URD32D08A0700

800

690

115

600

110/120

L300183

PC32UD69V800A

6,9URD32D08A0800

900

660

170

900

110/125

M300184

PC32UD69V900A

6,9URD32D08A0900

1000

660

240

1250

115/135

N300185

PC32UD69V1000A

6,9URD32D08A1000

1100

600

270

1620

140/165

W302101

PC32UD60V1100A

6URD32D08A1100

1250

500

410

1940

150/180

G300409

PC32UD50V1250A

5,5URD32D08A1250

500

690

19

100

105

G300248

PC33UD69V500A

6,9URD33D08A0500

550

690

27

140

105/110

H300249

PC33UD69V550A

6,9URD33D08A0550

630

690

40

130

110/120

J300250

PC33UD69V630A

6,9URD33D08A0630

700

690

55

300

115/125

K300251

PC33UD69V700A

6,9URD33D08A0700

800

690

95

490

120/130

L300252

PC33UD69V800A

6,9URD33D08A0800

900

690

135

700

120/135

M300253

PC33UD69V900A

6,9URD33D08A0900

1000

690

170

900

135/155

N300254

PC33UD69V1000A

6,9URD33D08A1000

1100

690

240

1260

135/160

P300255

PC33UD69V1100A

6,9URD33D08A1100

1250

660

350

1850

150/180

Q300256

PC33UD69V1250A

6,9URD33D08A1250

1400

660

480

2500

160/200

R300257

PC33UD69V1400A

6,9URD33D08A1400

1500

600

500

220

M235071

PC33UD60V1500A

6URD33D08A1500

1600

600

555

210/240

X301803

PC33UD60V1600A

6URD33D08A1600

1800

600

720

225/260

E301971

PC33UD60V1800A

6URD33D08A1800

660VAC (A²s

Rated Current

x 10³)

(W)

0.116

0.68

0.2

1.09

690

0.33

100

690

125

** Watts loss data is published for both blade and tapped style mounting configurations. When two watts loss values are shown this represents tapped/blade values
respectively.

D48

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

690/700 Volt PSC Square Body
Body Size

30

31

32

33

Total I²t @

** Watts Loss

660VAC

@ Rated

(A²s x 10³)

Current (W)

0.116

0.68

690

0.2

80

690

100
125

Amp

Rated

Melting I²t

Rating

Voltage

(A²s x 10³)

50

690

63

Catalog No

New Description

Old Description

9

R300372

PC30UD69V50EF

6,9URD30EF0050

1.09

14

H300088

PC30UD69V63EF

6,9URD30EF0063

0.33

1.75

19

J300089

PC30UD69V80EF

6,9URD30EF0080

690

0.47

2.5

26

K300090

PC30UD69V100EF

6,9URD30EF0100

690

0.85

4.5

30

L300091

PC30UD69V125EF

6,9URD30EF0125

160

690

1.6

8.5

37

M300092

PC30UD69V160EF

6,9URD30EF0160

200

690

3

15.5

42/43

N300093

PC30UD69V200EF

6,9URD30EF0200

250

690

5.8

30

48/50

P300094

PC30UD69V250EF

6,9URD30EF0250

315

690

12

62

53/55

Q300095

PC30UD69V315EF

6,9URD30EF0315

350

690

15.5

80

57/60

R300096

PC30UD69V350EF

6,9URD30EF0350

400

690

23

120

60/65

S300097

PC30UD69V400EF

6,9URD30EF0400

200

690

2.6

14

45

C300037

PC31UD69V200EF

6,9URD31EF0200

250

690

4.7

25

52

D300038

PC31UD69V250EF

6,9URD31EF0250

315

690

7.5

40

65

E300039

PC31UD69V315EF

6,9URD31EF0315

350

690

10.5

55

67

N300047

PC31UD69V350EF

6,9URD31EF0350

400

690

19

100

68

F300040

PC31UD69V400EF

6,9URD31EF0400

450

690

26.5

140

70

G300041

PC31UD69V450EF

6,9URD31EF0450

500

690

37

195

70/72

H300042

PC31UD69V500EF

6,9URD31EF0500

550

690

52

280

70/75

J300043

PC31UD69V550EF

6,9URD31EF0550

630

690

75

390

75/85

K300044

PC31UD69V630EF

6,9URD31EF0630

700

690

95

490

85/95

L300045

PC31UD69V700EF

6,9URD31EF0700

400

690

15

80

72/75

V300168

PC32UD69V400EF

6,9URD32EF0400

450

690

22

115

77/80

W300169

PC32UD69V450EF

6,9URD32EF0450

500

690

28

145

85/90

X300170

PC32UD69V500EF

6,9URD32EF0500

550

690

37

195

90/95

Y300171

PC32UD69V550EF

6,9URD32EF0550

630

690

54

280

95/105

Z300172

PC32UD69V630EF

6,9URD32EF0630

700

690

76

400

100/110

A300173

PC32UD69V700EF

6,9URD32EF0700

800

690

115

600

110/120

B300174

PC32UD69V800EF

6,9URD32EF0800

900

660

170

900

110/125

C300175

PC32UD69V900EF

6,9URD32EF0900

1000

660

240

1250

115/135

D300176

PC32UD69V1000EF

6,9URD32EF1000

500

690

19

100

105

Z300218

PC33UD69V500EF

6,9URD33EF0500

550

690

27

140

105/110

A300219

PC33UD69V550EF

6,9URD33EF0550

630

690

40

130

110/120

B300220

PC33UD69V630EF

6,9URD33EF0630

700

690

55

300

115/125

C300221

PC33UD69V700EF

6,9URD33EF0700

800

690

95

490

120/130

D300222

PC33UD69V800EF

6,9URD33EF0800

900

690

135

700

120/135

E300223

PC33UD69V900EF

6,9URD33EF0900

1000

690

170

900

135/155

F300224

PC33UD69V1000EF

6,9URD33EF1000

1100

690

240

1260

135/160

G300225

PC33UD69V1100EF

6,9URD33EF1100

1250

660

350

1850

150/180

H300226

PC33UD69V1250EF

6,9URD33EF1250

1400

660

480

2500

160/200

J300227

PC33UD69V1400EF

6,9URD33EF1400

D

690 Volt European/IEC Style Ratings and Application Data, EF Mounting

** Watts loss data is published for both blade and tapped style mounting configurations. When two watts loss values are shown this represents tapped/blade values respectively.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D49

690/700 Volt PSC Square Body
690 Volt European/IEC Style Ratings and Application Data, TTF Mounting
Body Size

30

31

32

33

Total I²t

** Watts Loss

@ 660VAC

@ Rated

(A²s x 10³)

Current (W)

Amp

Rated

Melting I²t

Rating

Voltage

(A²s x 10³)

50

690

0.116

0.68

9

S300373C

PC30UD69V50TF

6,9URD30TTF0050

63

690

0.2

1.09

14

M300000C

PC30UD69V63TF

6,9URD30TTF0063

Catalog No

New Description

Old Description

80

690

0.33

1.75

19

S300051C

PC30UD69V80TF

6,9URD30TTF0080

100

690

0.47

2.5

26

T300052C

PC30UD69V100TF

6,9URD30TTF0100

125

690

0.85

4.5

30

V300053C

PC30UD69V125TF

6,9URD30TTF0125

160

690

1.6

8.5

37

W300054C

PC30UD69V160TF

6,9URD30TTF0160

200

690

3

15.5

42/43

X300055C

PC30UD69V200TF

6,9URD30TTF0200

250

690

5.8

30

48/50

Y300056C

PC30UD69V250TF

6,9URD30TTF0250

315

690

12

62

53/55

Z300057C

PC30UD69V315TF

6,9URD30TTF0315

350

690

15.5

80

57/60

A300058C

PC30UD69V350TF

6,9URD30TTF0350

400

690

23

120

60/65

B300059C

PC30UD69V400TF

6,9URD30TTF0400

450

660

26

153

80/88

V300398C

PC30UD69V450TF

6,9URD30TTF0450
6,9URD30TTF0500

500

660

41

245

80/88

W300399C

PC30UD69V500TF

550

660

52

305

80/90

X300400C

PC30UD69V550TF

6,9URD30TTF0550

200

690

2.6

14

45

N300001C

PC31UD69V200TF

6,9URD31TTF0200

250

690

4.7

25

52

P300002C

PC31UD69V250TF

6,9URD31TTF0250

315

690

7.5

40

65

Q300003C

PC31UD69V315TF

6,9URD31TTF0315

350

690

10.5

55

67

M300046C

PC31UD69V350TF

6,9URD31TTF0350

400

690

19

100

68

R300004C

PC31UD69V400TF

6,9URD31TTF0400
6,9URD31TTF0450

450

690

26.5

140

70

S300005C

PC31UD69V450TF

500

690

37

195

70/72

T300006C

PC31UD69V500TF

6,9URD31TTF0500

550

690

52

280

70/75

V300007C

PC31UD69V550TF

6,9URD31TTF0550

630

690

75

390

75/85

W300008C

PC31UD69V630TF

6,9URD31TTF0630

700

690

95

490

85/95

X300009C

PC31UD69V700TF

6,9URD31TTF0700

800

660

140

815

105/120

Y300401C

PC31UD69V800TF

6,9URD31TTF0800

400

690

15

80

72/75

H300065C

PC32UD69V400TF

6,9URD32TTF0400

450

690

22

115

77/80

J300066C

PC32UD69V450TF

6,9URD32TTF0450

500

690

28

145

85/90

K300067C

PC32UD69V500TF

6,9URD32TTF0500
6,9URD32TTF0550

550

690

37

195

90/95

L300068C

PC32UD69V550TF

630

690

54

280

95/105

M300069C

PC32UD69V630TF

6,9URD32TTF0630

700

690

76

400

100/110

N300070C

PC32UD69V700TF

6,9URD32TTF0700

800

690

115

600

110/120

P300071C

PC32UD69V800TF

6,9URD32TTF0800

900

660

170

900

110/125

Q300072C

PC32UD69V900TF

6,9URD32TTF0900

1000

660

240

1250

115/135

S300074C

PC32UD69V1000TF

6,9URD32TTF1000

1100

600

270

1620

140/165

M300759C

PC32UD60V1100TF

6URD32TTF1100
5,5URD32TTF1250

1250

500

410

1940

150/180

P301060C

PC32UD55V1250TF

500

690

19

100

105

V300076C

PC33UD69V500TF

6,9URD33TTF0500

550

690

27

140

105/110

W300077C

PC33UD69V550TF

6,9URD33TTF0550

630

690

40

130

110/120

X300078C

PC33UD69V630TF

6,9URD33TTF0630

700

690

55

300

115/125

Y300079C

PC33UD69V700TF

6,9URD33TTF0700

800

690

95

490

120/130

Z300080C

PC33UD69V800TF

6,9URD33TTF0800

900

690

135

700

120/135

A300081C

PC33UD69V900TF

6,9URD33TTF0900

1000

690

170

900

135/155

B300082C

PC33UD69V1000TF

6,9URD33TTF1000

1100

690

240

1260

135/160

C300083C

PC33UD69V1100TF

6,9URD33TTF1100
6,9URD33TTF1250

1250

660

350

1850

150/180

D300084C

PC33UD69V1250TF

1400

660

480

2500

160/200

E300085C

PC33UD69V1400TF

6,9URD33TTF1400

1500

600

500

220

Y300585C

PC33UD60V1500TF

6URD33TTF1500

1600

600

555

210/240

Z300586C

PC33UD60V1600TF

6URD33TTF1600

1800

600

720

225/260

A300587C

PC33UD60V1800TF

6URD33TTF1800

2000

550

950

250/290

B300588C

PC33UD55V2000TF

5,5URD33TTF2000

2250

500

1250

280/330

K300757C

PC33UD50V2250TF

5URD33TTF2250

2500

450

1870

280/330

L300758C

PC33UD45V2500TF

4,5URD33TTF2500

** Watts loss data is published for both blade and tapped style mounting configurations. When two watts loss values are shown this represents tapped/blade
values respectively.

D50

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

690/700 Volt PSC Square Body
700 Volt North American Style Ratings and Application Data, LI Mounting

30

31

32

33

Total I²t

** Watts Loss

@ 660VAC

@ Rated

Amp

Rated

Melting I²t

Rating

Voltage

(A²s x 10³)

(A²s x 10³)

Current (W)

63

700

0.2

1.2

14

M300138

A070UD30LI63

A070URD30LI0063

80

700

0.33

1.9

19

N300139

A070UD30LI080

A070URD30LI0080

Catalog No

New Description

Old Description

100

700

0.47

2.7

26

P300140

A070UD30LI100

A070URD30LI0100

125

700

0.85

4.9

30

Q300141

A070UD30LI125

A070URD30LI0125

160

700

1.6

9.2

37

R300142

A070UD30LI160

A070URD30LI0160

200

700

3

16.7

42/43

S300143

A070UD30LI200

A070URD30LI0200

250

700

5.8

32.4

48/50

T300144

A070UD30LI250

A070URD30LI0250

315

700

12

67

53/55

V300145

A070UD30LI315

A070URD30LI0315

350

700

15.5

86

57/60

W300146

A070UD30LI350

A070URD30LI0350

400

700

23

130

60/65

X300147

A070UD30LI400

A070URD30LI0400

450

700

26

165

80/88

K300527

A070UD30LI450

A070URD30LI0450

500

700

41

264

80/88

L300528

A070UD30LI500

A070URD30LI0500

550

700

52

330

80/90

M300529

A070UD30LI550

A070URD30LI0550

200

700

2.5

14.6

45

V300697

A070UD31LI200

A070URD31LI0200

250

700

4.7

27

52

W300698

A070UD31LI250

A070URD31LI0250

315

700

7.5

43

65

X300699

A070UD31LI315

A070URD31LI0315

350

700

10.5

59

67

Y300700

A070UD31LI350

A070URD31LI0350

400

700

19

110

68

Z300701

A070UD31LI400

A070URD31LI0400

450

700

26.5

150

70

A300702

A070UD31LI450

A070URD31LI0450

500

700

37

210

70/72

B300703

A070UD31LI500

A070URD31LI0500

550

700

52

300

70/75

C300704

A070UD31LI550

A070URD31LI0550

630

700

75

421

75/85

D300705

A070UD31LI630

A070URD31LI0630

700

700

95

530

85/95

E300706

A070UD31LI700

A070URD31LI0700

800

700

140

880

105/120

F300707

A070UD31LI800

A070URD31LI0800

400

700

15

86

72/75

J300204

A070UD32LI400

A070URD32LI0400

450

700

22

124

77/80

K300205

A070UD32LI450

A070URD32LI0450

500

700

28

157

85/90

L300206

A070UD32LI500

A070URD32LI0500

550

700

37

211

90/95

M300207

A070UD32LI550

A070URD32LI0550

630

700

54

302

95/105

N300208

A070UD32LI630

A070URD32LI0630

700

700

76

432

100/110

P300209

A070UD32LI700

A070URD32LI0700

800

700

115

648

110/120

Q300210

A070UD32LI800

A070URD32LI0800

900

700

170

972

110/125

R300211

A070UD32LI900

A070URD32LI0900

1000

700

240

1350

115/135

S300212

A070UD32LI1000

A070URD32LI1000

1100

650

270

1620

140/165

B301071

A065UD32LI1100

A065URD32LI1100

1250

600

410

2100

150/180

C301072

A060UD32LI1250

A060URD32LI1250

1400

550

555

2600

160/190

D301073

A055UD32LI1400

A055URD32LI1400

1600

550

870

4000

165/195

E301074

A055UD32LI1600

A055URD32LI1600

1800

500

1050

4400

195/330

F301075

A050UD32LI1800

A050URD32LI1800

500

700

19

108

105

K300228

A070UD33LI500

A070URD33LI0500

550

700

27

151

105/110

L300229

A070UD33LI550

A070URD33LI0550

630

700

40

227

110/120

M300230

A070UD33LI630

A070URD33LI0630

700

700

55

324

115/125

N300231

A070UD33LI700

A070URD33LI0700

800

700

95

529

120/130

P300232

A070UD33LI800

A070URD33LI0800

900

700

135

760

120/135

Q300233

A070UD33LI900

A070URD33LI0900

1000

700

170

970

135/155

R300234

A070UD33LI1000

A070URD33LI1000

1100

700

240

1360

135/160

S300235

A070UD33LI1100

A070URD33LI1100

2000
2700

150/180
160/200

T300236
V300237

A070UD33LI1250
A070UD33LI1400

A070URD33LI1250
A070URD33LI1400

1250

700

350

1400
1600

700
650

480
555

1800

650

720

3250

210/240

G301076

A065UD33LI1600

A065URD33LI1600

4330

225/260

H301077

A065UD33LI1800

A065URD33LI1800

2000

600

950

5000

250/290

J301078

A060UD33LI2000

A060URD33LI2000

2250

550

1250

5900

280/330

K301079

A055UD33LI2250

A055URD33LI2250

2500

500

1870

7600

280/330

L301080

A050UD33LI2500

A050URD33LI2500

D

Body Size

** Watts loss data is published for both blade and tapped style mounting configurations. When two watts loss values are shown this represents tapped/blade
values respectively.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D51

690/700 Volt PSC Square Body
700 Volt North American Style Ratings and Application Data, KI Mounting
Body
Size

30

31

32

33

Total I²t

Rated

Melting I²t

Voltage

(A²s x 10³)

63

700

0.2

11.2

80

700

0.33

1.9

100

700

0.47

125

700

160
200

** Watts
Loss @

Catalog No

New Description

Old Description

14

B300128

A070UD30KI63

A070URD30KI0063

19

C300129

A070UD30KI80

A070URD30KI0080

2.7

26

D300130

A070UD30KI100

A070URD30KI0100

0.85

4.9

30

E300131

A070UD30KI125

A070URD30KI0125

700

1.6

9.2

37

F300132

A070UD30KI160

A070URD30KI0160

700

3

16.7

42/43

G300133

A070UD30KI200

A070URD30KI0200

250

700

5.8

32.4

48/50

H300134

A070UD30KI250

A070URD30KI0250

315

700

12

67

53/55

J300135

A070UD30KI315

A070URD30KI0315

350

700

15.5

86

57/60

K300136

A070UD30KI350

A070URD30KI0350

400

700

23

130

60/65

L300137

A070UD30KI400

A070URD30KI0400

450

700

26

165

80/88

T301064

A070UD30KI450

A070URD30KI0450

500

700

41

264

80/88

V301065

A070UD30KI500

A070URD30KI0500

550

700

52

330

80/90

W301066

A070UD30KI550

A070URD30KI0550

200

700

2.5

14.6

45

S300028

A070UD31KI200

A070URD31KI0200

250

700

4.7

27

52

T300029

A070UD31KI250

A070URD31KI0250

315

700

7.5

43

65

V300030

A070UD31KI315

A070URD31KI0315

350

700

10.5

59

67

R300050

A070UD31KI350

A070URD31KI0350

400

700

19

110

68

W300031

A070UD31KI400

A070URD31KI0400

450

700

26.5

150

70

X300032

A070UD31KI450

A070URD31KI0450

500

700

37

210

70/72

Y300033

A070UD31KI500

A070URD31KI0500

550

700

52

300

70/75

Z300034

A070UD31KI550

A070URD31KI0550

630

700

75

421

75/85

A300035

A070UD31KI630

A070URD31KI0630

700

700

95

530

85/95

B300036

A070UD31KI700

A070URD31KI0700

800

700

140

880

105/120

A301070

A070UD31KI800

A070URD31KI0800

400

700

15

86

72/75

Z300195

A070UD32KI400

A070URD32KI0400

450

700

22

124

77/80

A300196

A070UD32KI450

A070URD32KI0450

500

700

28

157

85/90

B300197

A070UD32KI500

A070URD32KI0500

550

700

37

211

90/95

C300198

A070UD32KI550

A070URD32KI0550

630

700

54

302

85/105

D300199

A070UD32KI630

A070URD32KI0630

700

700

76

432

100/110

E300200

A070UD32KI700

A070URD32KI0700

800

700

115

648

110/120

F300201

A070UD32KI800

A070URD32KI0800

900

700

170

972

110/125

G300202

A070UD32KI900

A070URD32KI0900

1000

700

240

1350

115/135

H300203

A070UD32KI1000

A070URD32KI1000

500

700

19

108

105

W300238

A070UD33KI500

A070URD33KI0500

550

700

27

151

105/110

X300239

A070UD33KI550

A070URD33KI0550

630

700

40

227

110/120

Y300240

A070UD33KI630

A070URD33KI0630

700

700

55

324

115/125

Z300241

A070UD33KI700

A070URD33KI0700

800

700

95

529

120/130

A300242

A070UD33KI800

A070URD33KI0800

900

700

135

760

120/135

B300243

A070UD33KI900

A070URD33KI0900

1000

700

170

970

135/155

C300244

A070UD33KI1000

A070URD33KI1000

1100

700

240

1360

135/160

D300245

A070UD33KI1100

A070URD33KI1100

1250

700

350

2000

150/180

E300246

A070UD33KI1250

A070URD33KI1250

1400

700

480

2700

160/200

F300247

A070UD33KI1400

A070URD33KI1400

1600

650

555

3250

210/240

E302063

A065UD33KI1600

A065URD33KI1600

Amp Rating

@ 660VAC
(A²s x 10³)

Rated
Current (W)

** Watts loss data is published for both blade and tapped style mounting configurations. When two watts loss values are shown this represents tapped/blade
values respectively.

D52

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

690/700 Volt PSC Square Body
Body Size

30

31

32

33

Total I²t

** Watts Loss

@ 660VAC

@ Rated

(A²s x 10³)

Current (W)

0.2

1.2

0.33

1.9

700

0.47

125

700

160

Rated

Melting I²t

Voltage

(A²s x 10³)

63

700

80

700

100

Catalog No

New Description

Old Description

14

A301967

A070UD30TTI63

A070URD30TTI0063

19

V301962

A070UD30TTI80

A070URD30TTI0080

2.7

26

W300744

A070UD30TTI100

A070URD30TTI0100

0.85

4.9

30

G300708

A070UD30TTI125

A070URD30TTI0125

700

1.6

9.2

37

N300576

A070UD30TTI160

A070URD30TTI0160

200

700

3

16.7

42/43

P300577

A070UD30TTI200

A070URD30TTI0200

250

700

5.8

32.4

48/50

Q300578

A070UD30TTI250

A070URD30TTI0250

315

700

12

67

53/55

R300579

A070UD30TTI315

A070URD30TTI0315

350

700

15.5

86

57/60

S300580

A070UD30TTI350

A070URD30TTI0350

400

700

23

130

60/65

T300581

A070UD30TTI400

A070URD30TTI0400

450

700

26

165

80/88

V300582

A070UD30TTI450

A070URD30TTI0450

500

700

41

264

80/88

W300583

A070UD30TTI500

A070URD30TTI0500

550

700

52

330

80/90

X300584

A070UD30TTI550

A070URD30TTI0550

200

700

2.5

14.6

45

A300472

A070UD31TTI200

A070URD31TTI0200

250

700

4.7

27

52

B300473

A070UD31TTI250

A070URD31TTI0250

315

700

7.5

43

65

C300474

A070UD31TTI315

A070URD31TTI0315

350

700

10.5

59

67

D300475

A070UD31TTI350

A070URD31TTI0350

400

700

19

110

68

E300476

A070UD31TTI400

A070URD31TTI0400

450

700

26.5

150

70

F300477

A070UD31TTI450

A070URD31TTI0450

500

700

37

210

70/72

G300478

A070UD31TTI500

A070URD31TTI0500

550

700

52

300

70/75

H300479

A070UD31TTI550

A070URD31TTI0550

630

700

75

421

75/85

J300480

A070UD31TTI630

A070URD31TTI0630

700

700

95

530

85/95

K300481

A070UD31TTI700

A070URD31TTI0700

800

700

140

880

105/120

L300482

A070UD31TTI800

A070URD31TTI0800

400

700

15

86

72/75

Q300463

A070UD32TTI400

A070URD32TTI0400

450

700

22

124

77/80

N300461

A070UD32TTI450

A070URD32TTI0450

500

700

28

157

85/90

P300462

A070UD32TTI500

A070URD32TTI0500

550

700

37

211

90/95

R300464

A070UD32TTI550

A070URD32TTI0550

630

700

54

302

95/105

S300465

A070UD32TTI630

A070URD32TTI0630

700

700

76

432

100/110

T300466

A070UD32TTI700

A070URD32TTI0700

800

700

115

648

110/120

V300467

A070UD32TTI800

A070URD32TTI0800

900

700

170

972

110/125

W300468

A070UD32TTI900

A070URD32TTI0900

1000

700

240

1350

115/135

X300469

A070UD32TTI1000

A070URD32TTI1000

1100

650

270

1620

140/165

M301081

A065UD32TTI1100

A065URD32TTI1100

1250

600

410

2100

150/180

N301082

A060UD32TTI1250

A060URD32TTI1250

1400

550

555

2600

160/190

P301083

A055UD32TTI1400

A055URD32TTI1400

1600

550

870

4000

165/195

Q301084

A055UD32TTI1600

A055URD32TTI1600

1800

500

1050

4400

195/330

R301085

A050UD32TTI1800

A050URD32TTI1800

500

700

19

108

105

X300446

A070UD33TTI500

A070URD33TTI0500

550

700

27

151

105/110

Y300447

A070UD33TTI550

A070URD33TTI0550

630

700

40

227

110/120

Z300448

A070UD33TTI630

A070URD33TTI0630

700

700

55

324

115/125

A300449

A070UD33TTI700

A070URD33TTI0700

800

700

95

529

120/130

T300443

A070UD33TTI800

A070URD33TTI0800

900

700

135

760

120/135

B300450

A070UD33TTI900

A070URD33TTI0900

1000

700

170

970

135/155

C300451

A070UD33TTI1000

A070URD33TTI1000

1100

700

240

1360

135/160

D300452

A070UD33TTI1100

A070URD33TTI1100

1250

700

350

2000

1400
1600

700
650

480
555

2700
3250

150/180
160/200

E300453
F300454

A070UD33TTI1250
A070UD33TTI1400

A070URD33TTI1250
A070URD33TTI1400

210/240

S301086

A065UD33TTI1600

A065URD33TTI1600

1800

650

720

4330

225/260

T301087

A065UD33TTI1800

A065URD33TTI1800

2000

600

950

5000

250/290

V301088

A060UD33TTI2000

A060URD33TTI2000

2250

550

1250

5900

280/330

W301089

A055UD33TTI2250

A055URD33TTI2250

2500

500

1870

7600

280/330

Y300838

A050UD33TTI2500

A050URD33TTI2500

Amp Rating

D

700 Volt North American Style Ratings and Application Data,TTI Mounting

** Watts loss data is published for both blade and tapped style mounting configurations. When two watts loss values are shown this represents tapped/blade
values respectively.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D53

690/700 Volt PSC Square Body
2x32, 2x33
Size

2 X 32

2 X 33

Catalog No

New Description

Old Description

T300213A

PC232UD69V10CTF

6,9URD232TTF1000

V300214A

PC232UD69V13CTF

6,9URD232TTF1250

G300087A

PC232UD69V14CTF

6,9URD232TTF1400

W300215A

PC232UD69V16CTD

6,9URD232TDF1600

X300216A

PC232UD69V18CTD

6,9URD232TDF1800

Y300217A

PC232UD69V20CTD

6,9URD232TDF2000

D301993A

PC232UD55V22CTD

5,5URD232TDF2200

D300268A

PC233UD69V13CTF

6,9URD233TTF1250

E300269A

PC233UD69V14CTF

6,9URD233TTF1400

F300270A

PC233UD69V16CTF

6,9URD233TTF1600

B300427A

PC36UD69V18CP11

6,9URD233PLAF1800

R302235A

PC36UD60V20CP11

6URD233PLAF2000

Q302234A

PC36UD60V22CP11

6URD233PLAF2200

P302233A

PC36UD60V25CP11

6URD233PLAF2500

N302232A

PC36UD60V28CP11

6URD233PLAF2800

L301977A

PC36UD55V30CP11

5,5URD233PLAF3000

M301978A

PC36UD55V32CP11

5,5URD233PLAF3200

N301979A

PC36UD50V36CP11

5URD233PLAF3600

P301980A

PC36UD50V40CP11

5URD233PLAF4000

Q301981A

PC36UD45V45CP11

4,5URD233PLAF4500

R301982A

PC36UD40V50CP11

4URD233PLAF5000

Weight (g)
1240

3300

1900

2000

Dimensions (mm)
Size

A

B

C

D

E

F

G

H

J

K

d

e

L

M

N

2x32 TT

60

138,5

172

11

67,6

66,5

100

35

61

40

M 10

4

107,5

48

72

2x33 TT

74,5

167

200

13

67,6

81

114

50

80

40

M 12

4

107,5

54

86

2x32 TD

65,5

147

182

-

91,5

-

-

30

-

60

M 10

12

140

-

-

2x33 PLAF

75

171,5

207

-

55,5

-

115

40

-

71

M 10

15

81

-

-

PLAF

Studs and
microswitches
supplied
separately

D54

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

1250/1300 Volt PSC Square Body
Mersen 1250/1300V PSC fuse-links provide maximum flexibility in equipment design
and ultimate protection for today’s power conversion equipment. These square body
fuse-links are available in four different body sizes, each size having four worldwide
acceptable mounting styles. The different mounting styles and body sizes along with
a broad range of ampere ratings allow greatest flexibility in equipment design.
Mersen PSC fuses have been engineered to provide state-of-the-art protection for
SCR’s, diodes, thyristors, GTO’s and IGBT devices. They have pure silver die-cut
elements embedded in solidified sand which helps control arcing characteristics

D

for low I2t and high interrupting rating. All contact surfaces are silver plated and all
hardware is non-magnetic.
All fuse links are equipped with a low voltage trip-indicator. This trip-indicator can
operate a field mountable microswitch which is easily mounted directly onto the fuse
even while in service.

Ratings:
Volts	

Features/Benefits:

: 650-1300 VAC

Amps	 : AC - 50-1800A

•• Choice of mounting styles gives wide choice for equipment design

I.R.	

: 100kA I.R. AC

•• Broad range of ampere ratings in a given body size for design flexibility

DC	

: Consult Factory

•• IEC 269-4 compliance for fuses for worldwide semiconductor applications
*For Microswitch information see page J9

Approvals:
•• UL recognized	component File

Highlights:

Applications:

•• Extremely fast acting

•• Protection of rectifiers, inverters,

E76491

•• Current limiting

DC drives, UPS Systems, reduced

•• Very low I t

voltage motor starters, and other

•• Superior cycling ability

equipment in globally accepted

2

•• Sizes 70,71,72,73 tested to IEC
269.4

applications

Part Number Designation:
12,5 URD: 	

European/IEC

		

Mounting Style/Approval

		

Tested @ 1.1 Vn

A130 URD:	 North American
		

Mounting Style/Approval

		

Tested @ Vn	

*Vn = rated voltage

N.
		American Reference Numbering System
A 130	 URD	 71	

I	 350

A.C.				
	
	Rated Volts
(030=1300V)	

	
Class
Size	

	
Mounting Types	

European
Reference Numbering System
		

70
71
72
73

Straight-blade	
LI
	Straight-blade
LLI
	Flat-type, one hole
TTI
(American)			

12.5	URD	 71	

				
	
	Rated Volts
(12.5=1250V)	

	
Class
Size	

	
Mounting Types	 	
DIN 110

70
71
72
73
D11A

	Flat-type, one hole (metric) TTF

			

Indicator

Indicator

Amp Rating

Amp Rating

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

I	 350

www.barr-thorp.com

D55

1250/1300 Volt PSC Square Body
European Blade DIN 110, Type D11A
Body
Size

Dimensions - mm (in)

Type

A

B

C

D

E

G

70

40

(1.57)

25

(.98)

12.5 (.49)

21

17

(.67)

100.4 (3.95)

133.4 (5.25)

71

51

(2.01)

25

(.98)

12.5 (.49)

25.5 (1.00)

22.5

(.89)

100.4 (3.95)

133.4 (5.25)

60

(2.36)

32

(1.26)

16

(.63)

30

27

(1.06)

100.4 (3.95)

133.4 (5.25)

74.5 (2.93)

40

(1.57)

20

(.79)

37.2 (1.46)

34.25 (1.35)

100.4 (3.95)

133.4 (5.25)

D11

72
73

(.83)

F

(1.18)

North American Straight Blade, Types LI & LLI
Body
Size

Dimensions - mm (in)

Type

70

LI

71

LLI

72
LI

73

A

B

C

D

E

F

G

H

J

40

25

12.5

21

18

91.4

130.4

152.4

10.5

(1.57)

(0.98)

(0.49)

(0.83)

(0.71)

(3.60)

(5.13)

(6.00)

(0.41)

51

25

12.5

25.5

22.5

91.4

130.4

152.4

14.6

(2.01)

(0.98)

(0.49)

(1.00)

(0.89)

(3.60)

(5.13)

(6.00)

(0.57)

60

32

16

30

27

97.6

132.4

157.4

14.6

(2.36)

(1.26)

(0.63)

(1.18)

(1.06)

(3.84)

(5.2)

(6.20)

(0.57)

74.5

40

20

37.2

34.2

98.8

132.4

157.4

15.9

(2.93)

(1.57)

(0.79)

(1.46)

(1.35)

(3.89)

(5.21)

(6.20)

(0.63)

Outline Dimensions
Type D11A
4.7

10.5

10.5

C

A

B
D

H

F

71

E

6

G

A

Types LI and LLI

J

C

A

B
D

72.5 MAX
(2.85)
F
G
H

D56

5.03
(.2)

6
(.24)

E
A

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

1250/1300 Volt PSC Square Body
1250/1300 Volt North American and European Flat Single Hole, Type TTI/TTF
Body Size

Type

70
71
72

TTI/TTF

73

Dimensions - mm/(In)

Tapped Hole (N. A.)

A

C (TTI)

D (TTF)

B

Tapped Hole (EURO.)

40

(1.57)

25

(1.00)

5/16-18 X .23DP

M8 X 1.25 X 6 DP

50.8

(2.00)

30.2

(1.19)

5/16-18 X .36DP

M8 X 1.25 X 9 DP

60.3

(2.37)

38.1

(1.50)

3/8-16 X .36DP

M10 X 1.50 X 9 DP

74.6

(2.94)

46

(1.81)

M12 X 1.75 X DP

M12 X 1.75 X 9 DP

D

Types TTI and TTF
C

A

5.03
(.20)

B

74
(2.91)

A

72.5 MAX
(2.85)

Standard Threaded Studs
Size

Ref. and Dimension Per Pair of Studs

Weight (g)

Max Stud

Max Nut Tightening

Mounting

Torque (Nm)

Torque (Nm)
70 & 71

S 98 801 (HC M8 X 30 & M 8 X 35)

23

72

T 98 802 (HC M 10 X 30 & M 10 X 50)

40

73

V 98 803 (HC M 12 X 35 & M 12 X 50)

60

2X72

W 98 804 (HC M 10 X 50)

50

2X73

X 98 805 (HC M 12 X 50)

70

13

15

Fig. 1

Fig. 2

Fig. 3

13.5

13.5

13.5

26

26

26

46

46

15

26

26

26

46

46

15

Packaging: 6 pairs

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D57

1250/1300 Volt PSC Square Body
1250 Volt European/IEC Style Ratings and Application Data, D11A Mounting
Body
Size

70

71

72

73

Total I²t

** Watts Loss

@ 660VAC

@ Rated

(A²s x 10³)

Current (W)

0.116

0.98

0.21

1.7

1250

0.47

100

1250

125

Rated

Melting I²t

Voltage

(A²s x 10³)

50

1250

63

1250

80

Catalog No

New Description

Old Description

16

J301906

PC70UD13C50D1A

12,5URD70D11A0050

26

V300536

PC70UD13C63D1A

12,5URD70D11A0063

3.8

27

W300537

PC70UD13C80D1A

12,5URD70D11A0080

0.83

6.7

30

X300538

PC70UD13C100D1A

12,5URD70D11A0100

1250

1.3

10.5

38

Y300539

PC70UD13C125D1A

12,5URD70D11A0125

160

1250

2.5

21

45

Z300540

PC70UD13C160D1A

12,5URD70D11A0160

200

1250

4.7

37.8

54/56

A300541

PC70UD13C200D1A

12,5URD70D11A0200

250

1250

9.6

77

58/61

B300542

PC70UD13C250D1A

12,5URD70D11A0250

280

1200

14

107

61

J300710

PC70UD12C280D1A

12URD70D11A0280

315

1200

20

150

66

C300543

PC70UD12C315D1A

12URD70D11A0315

350

1100

28

180

68/75

D300544

PC70UD11C350D1A

11URD70D11A0350

400

1100

39

254

81

F300868

PC70UD11C400D1A

11URD70D11A0400

160

1250

2.6

21

46

D300751

PC71UD13C160D1A

12,5URD71D11A0160

200

1250

4.7

38

54

E300545

PC71UD13C200D1A

12,5URD71D11A0200

250

1250

8.9

71

61

F300546

PC71UD13C250D1A

12,5URD71D11A0250

315

1250

16

130

73/76

G300547

PC71UD13C315D1A

12,5URD71D11A0315

350

1250

22

180

76/80

H300548

PC71UD13C350D1A

12,5URD71D11A0350

400

1250

38

310

76/80

J300549

PC71UD13C400D1A

12,5URD71D11A0400

450

1250

47

380

87/95

K300550

PC71UD13C450D1A

12,5URD71D11A0450

500

1100

68

440

90/100

L300551

PC71UD11C500D1A

11URD71D11A0500

550

1100

84

540

98/112

M300552

PC71UD11C550D1A

11URD71D11A0550

630

1000

125

810

105

N300553

PC71UD10C630D1A

10URD71D11A0630

280

1250

10

84

72

P300554

PC72UD13C280D1A

12,5URD72D11A0280

315

1250

15

122

76

Q300555

PC72UD13C315D1A

12,5URD72D11A0315

350

1250

21

170

77

R300556

PC72UD13C350D1A

12,5URD72D11A0350

400

1250

32.5

270

80

S300557

PC72UD13C400D1A

12,5URD72D11A0400

450

1250

44

360

87/89

T300558

PC72UD13C450D1A

12,5URD72D11A0450

500

1250

57

460

94/98

V300559

PC72UD13C500D1A

12,5URD72D11A0500

550

1250

68

550

110/120

W300560

PC72UD13C550D1A

12,5URD72D11A0550

630

1100

105

850

113

X300561

PC72UD11C630D1A

11URD72D11A0630

700

1000

145

910

122

Y300562

PC72UD10C700D1A

10URD72D11A0700

800

1000

215

1400

125

Z300563

PC72UD10C800D1A

10URD72D11A0800

900

1000

312

1800

130

H300870

PC72UD10C900D1A

10URD72D11A0900

315

1250

12

95

84

A300564

PC73UD13C315D1A

12,5URD73D11A0315

350

1250

117

140

86

B300565

PC73UD13C350D1A

12,5URD73D11A0350

400

1250

25

200

93

C300566

PC73UD13C400D1A

12,5URD73D11A0400

450

1250

35.5

290

99/100

D300567

PC73UD13C450D1A

12,5URD73D11A0450

500

1250

44

360

110/112

E300568

PC73UD13C500D1A

12,5URD73D11A0500

550

1250

57

460

116/120

F300569

PC73UD13C550D1A

12,5URD73D11A0550

630

1250

84

680

125/132

G300570

PC73UD13C630D1A

12,5URD73D11A0630

700

1200

110

900

135

H300571

PC73UD12C700D1A

12URD73D11A0700

800

1100

190

1530

136

J300572

PC73UD11C800D1A

11URD73D11A0800

900

1000

250

1870

150

K300573

PC73UD10C900D1A

10URD73D11A0900

1000

900

370

2130

152

L300574

PC73UD90V10CD1A

9URD73D11A1000

1100

900

445

2470

168

M300575

PC73UD90V11CD1A

9URD73D11A1100

Amp Rating

** Watts loss data is published for both blade and tapped style mounting configurations. When two watts loss values are shown this represents tapped/blade
values respectively.

D58

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

1250/1300 Volt PSC Square Body
1250 Volt European/IEC Style Ratings and Application Data, TTF Mounting

70

71

72

73

Amp Rating

Rated

Melting I²t

Voltage

(A²s x 10³)

Total I²t

@

** Watts Loss

660VAC

@ Rated

(A²s x 10³)

Current (W)

Catalog No

New Description

Old Description

50

1250

0.116

0.98

16

C301095

PC70UD13C50TF

12,5URD70TTF0050

63

1250

0.21

1.7

26

M300483

PC70UD13C63TF

12,5URD70TTF0063

80

1250

0.47

3.8

27

N300484

PC70UD13C80TF

12,5URD70TTF0080

100

1250

0.83

6.7

30

P300485

PC70UD13C100TF

12,5URD70TTF0100

125

1250

1.3

10.5

38

Q300486

PC70UD13C125TF

12,5URD70TTF0125

160

1250

2.5

21

45

R300487

PC70UD13C160TF

12,5URD70TTF0160

200

1250

4.7

37.8

54/56

S300488

PC70UD13C200TF

12,5URD70TTF0200

250

1250

9.6

77

58/61

T300489

PC70UD13C250TF

12,5URD70TTF0250

280

1200

14

107

64

N300714

PC70UD12C280TF

12URD70TTF0280

315

1200

20

150

72

V300490

PC70UD12C315TF

12URD70TTF0315

350

1100

28

180

68/75

W300491

PC70UD11C350TF

11URD70TTF0350

400

1100

39

254

81

E300867

PC70UD11C400TF

11URD70TTF0400

160

1250

2.6

21

46

B300749

PC71UD13C160TF

12,5URD71TTF0160

200

1250

4.7

38

54

Z300517

PC71UD13C200TF

12,5URD71TTF0200

250

1250

8.9

71

61

A300518

PC71UD13C250TF

12,5URD71TTF0250

315

1250

16

130

73/76

B300519

PC71UD13C315TF

12,5URD71TTF0315

350

1250

22

180

76/80

C300520

PC71UD13C350TF

12,5URD71TTF0350

400

1250

38

310

76/80

D300521

PC71UD13C400TF

12,5URD71TTF0400

450

1250

47

380

87/95

E300522

PC71UD13C450TF

12,5URD71TTF0450

500

1100

68

440

90/100

F300523

PC71UD11C500TF

11URD71TTF0500

550

1100

84

540

98/112

G300524

PC71UD11C550TF

11URD71TTF0550

630

1100

125

810

120

H300525

PC71UD11C630TF

11URD71TTF0630

280

1250

10

84

72

Y300493

PC72UD13C280TF

12,5URD72TTF0280

315

1250

15

122

76

Z300494

PC72UD13C315TF

12,5URD72TTF0315

350

1250

21

170

77

A300495

PC72UD13C350TF

12,5URD72TTF0350

400

1250

32.5

270

80

B300496

PC72UD13C400TF

12,5URD72TTF0400

450

1250

44

360

87/89

C300497

PC72UD13C450TF

12,5URD72TTF0450

500

1250

57

460

94/98

D300498

PC72UD13C500TF

12,5URD72TTF0500

550

1250

68

550

110/120

E300499

PC72UD13C550TF

12,5URD72TTF0550

630

1250

105

850

125

F300500

PC72UD13C630TF

12,5URD72TTF0630

700

1100

145

910

140

G300501

PC72UD11C700TF

11URD72TTF0700

800

1100

215

1400

146

H300502

PC72UD11C800TF

11URD72TTF0800

900

1000

312

1800

130

G300869

PC72UD10C900TF

10URD72TTF0900

1000

850

-

-

136

T301294

PC72UD85V1000TF

8,5URD72TTF1000

315

1250

12

95

84

J300503

PC73UD13C315TF

12,5URD73TTF0315

350

1250

17

140

86

K300504

PC73UD13C350TF

12,5URD73TTF0350

400

1250

25

200

93

L300505

PC73UD13C400TF

12,5URD73TTF0400

450

1250

35.5

290

99/100

M300506

PC73UD13C450TF

12,5URD73TTF0450

500

1250

44

360

110/112

N300507

PC73UD13C500TF

12,5URD73TTF0500

550

1250

57

460

116/120

P300508

PC73UD13C550TF

12,5URD73TTF0550

630

1250

84

680

125/132

Q300509

PC73UD13C630TF

12,5URD73TTF0630

700

1250

110

900

146

R300510

PC73UD13C700TF

12,5URD73TTF0700

800

1250

190

1530

148

S300511

PC73UD13C800TF

12,5URD73TTF0800

900

1200

250

1870

170

T300512

PC73UD12C900TF

12URD73TTF0900

1000

1000

370

2130

174

V300513

PC73UD10C1000TF

10URD73TTF1000

1100

950

445

2470

208

W300514

PC73UD95V11CTF

9,5URD73TTF1100

1250

900

585

3050

186/200

T300696

PC73UD90V13CTF

9URD73TTF1250

1400

850

755

3700

210/228

S300718

PC73UD85C14CTF

8,5URD73TTF1400

1600

660

1430

5630

203

N304417

1800

600

2040

7600

206

C301302

PC73UD60V18CTF

6URD73TTF1800

D

Body Size

** Watts loss data is published for both blade and tapped style mounting configurations. When two watts loss values are shown this represents tapped/blade
values respectively.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D59

1250/1300 Volt PSC Square Body
1300 Volt North American Style Ratings and Application Data, LI, LLI Mounting
Body

Amp

Rated

Melting I²t

Size

Rating

Voltage

(A²s x 10³)

70

71

72

73

Total I²t

** Watts Loss

@ 660VAC

@ Rated

(A²s x 10³)

Current (W)

Catalog No

New Description

Old Description

63

1300

0.21

1.8

26

W300652

A130UD70LI063

A130URD70LI0063

80

1300

0.47

4

27

X300653

A130UD70LI080

A130URD70LI0080

100

1300

0.83

7.2

30

Y300654

A130UD70LI100

A130URD70LI0100

125

1300

1.3

11

38

Z300655

A130UD70LI125

A130URD70LI0125

160

1300

2.5

22

45

A300656

A130UD70LI160

A130URD70LI0160

200

1300

4.7

40

54/56

B300657

A130UD70LI200

A130URD70LI0200

250

1300

9.6

82

58/61

C300658

A130UD70LI250

A130URD70LI0250

315

1300

20

172

66/72

D300659

A130UD70LI315

A130URD70LI0315

350

1200

28

205

68/75

E300660

A120UD70LI350

A120URD70LI0350

160

1300

2.6

22

46

E300752

A130UD71LLI160

A130URD71LLI0160

200

1300

4.7

40

54

F300661

A130UD71LLI200

A130URD71LLI0200

250

1300

8.9

76

61

G300662

A130UD71LLI250

A130URD71LLI0250

280

1300

12

102

68/70

R300717

A130UD71LLI280

A130URD71LLI0280

315

1300

16

138

73/76

H300663

A130UD71LLI315

A130URD71LLI0315

350

1300

22

190

76/80

J300664

A130UD71LLI350

A130URD71LLI0350

400

1300

38

330

76/80

K300665

A130UD71LLI400

A130URD71LLI0400

450

1300

47

405

87/95

L300666

A130UD71LLI450

A130URD71LLI0450

500

1200

68

500

90/100

M300667

A120UD71LLI500

A120URD71LLI0500

550

1200

84

620

98/112

N300668

A120UD71LLI550

A120URD71LLI0550

630

1100

125

930

105

P300669

A110UD71LLI630

A110URD71LLI0630

280

1300

10

90

72

Q300670

A130UD72LI280

A130URD72LI0280

315

1300

15

130

76

R300671

A130UD72LI315

A130URD72LI0315

350

1300

21

180

77

S300672

A130UD72LI350

A130URD72LI0350

400

1300

32

285

80

T300673

A130UD72LI400

A130URD72LI0400

450

1300

44

380

87/89

V300674

A130UD72LI450

A130URD72LI0450

500

1300

57

500

94/98

W300675

A130UD72LI500

A130URD72LI0500

550

1300

68

590

110/120

X300676

A130UD72LI550

A130URD72LI0550

630

1200

105

920

113

Y300677

A120UD72LI630

A120URD72LI0630

700

1100

145

1040

122

Z300678

A110UD72LI700

A110URD72LI0700

800

1100

215

1590

125

A300679

A110UD72LI800

A110URD72LI0800

315

1300

12

102

84

B300680

A130UD73LI315

A130URD73LI0315

350

1300

17

150

86

C300681

A130UD73LI350

A130URD73LI0350

400

1300

25

220

93

D300682

A130UD73LI400

A130URD73LI0400

450

1300

35

310

99/100

E300683

A130UD73LI450

A130URD73LI0450

500

1300

44

390

110/112

F300684

A130UD73LI500

A130URD73LI0500

550

1300

57

500

116/120

G300685

A130UD73LI550

A130URD73LI0550

630

1300

84

730

125/132

H300686

A130UD73LI630

A130URD73LI0630

700

1300

110

960

135/146

J300687

A130UD73LI700

A130URD73LI0700

800

1200

190

1630

136

V301824

A130UD73LI800

A130URD73LI0800

900

1100

250

2160

150

L300689

A110UD73LI900

A110URD73LI0900

1000

1000

370

2430

152/174

M300690

A100UD73LI1000

A100URD73LI1000

1100

1000

445

2580

168/208

N300691

A100UD73LI1100

A100URD73LI1100

1250

1000

585

3480

186/200

J301193

A100UD73LI1250

A100URD73LI1250

1400

900

755

3880

210/228

K301194

A090UD73LI1400

A090URD73LI1400

1600

700

1430

5630

203

P300876

A070UD73LI1600

A070URD73LI1600

1800

650

2040

7600

206

A301599

A065UD73LI1800

A065URD73LI1800

** Watts loss data is published for both blade and tapped style mounting configurations. When two watts loss values are shown this represents tapped/blade
values respectively.

D60

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

1250/1300 Volt PSC Square Body
Body Size

70

71

72

73

Total I²t @

** Watts Loss

660VAC

@ Rated Current

(A²s x 10³)

(W)

0.21

1.8

0.47

4

1300

0.83

125

1300

160

Amp

Rated

Melting I²t

Rating

Voltage

(A²s x 10³)

63

1300

80

1300

100

Catalog No

New Description

Old Description

26

Q301015

A130UD70TTI63

A130URD70TTI0063

27

R301016

A130UD70TTI80

A130URD70TTI0080

7.2

30

S301017

A130UD70TTI100

A130URD70TTI0100

1.3

11

38

T301018

A130UD70TTI125

A130URD70TTI0125

1300

2.5

22

45

V301019

A130UD70TTI160

A130URD70TTI0160

200

1300

4.7

40

54/56

W301020

A130UD70TTI200

A130URD70TTI0200

250

1300

9.6

82

58/61

X301021

A130UD70TTI250

A130URD70TTI0250

315

1300

20

172

66/72

Z301023

A130UD70TTI315

A130URD70TTI0315

350

1200

28

205

68/75

A301024

A120UD70TTI350

A120URD70TTI0350

160

1300

2.6

22

46

B301025

A130UD71TTI160

A130URD71TTI0160

200

1300

4.7

40

54

C301026

A130UD71TTI200

A130URD71TTI0200

250

1300

8.9

76

61

D301027

A130UD71TTI250

A130URD71TTI0250

280

1300

12

102

68/70

E301028

A130UD71TTI280

A130URD71TTI0280

315

1300

16

138

73/76

F301029

A130UD71TTI315

A130URD71TTI0315

350

1300

22

190

76/80

G301030

A130UD71TTI350

A130URD71TTI0350

400

1300

38

330

76/80

H301031

A130UD71TTI400

A130URD71TTI0400

450

1300

47

405

87/95

J301032

A130UD71TTI450

A130URD71TTI0450

500

1200

68

500

90/100

K301033

A130UD71TTI500

A130URD71TTI0500

550

1200

84

620

98/112

L301034

A120UD71TTI550

A120URD71TTI0550

630

1200

125

930

120

M301035

A120UD71TTI630

A120URD71TTI0630

280

1300

10

90

72

N301036

A130UD72TTI280

A130URD72TTI0280

315

1300

15

130

76

P301037

A130UD72TTI315

A130URD72TTI0315

350

1300

21

180

77

Q301038

A130UD72TTI350

A130URD72TTI0350

400

1300

32

285

80

R301039

A130UD72TTI400

A130URD72TTI0400

450

1300

44

380

87/89

S301040

A130UD72TTI450

A130URD72TTI0450

500

1300

57

500

94/98

T301041

A130UD72TTI500

A130URD72TTI0500

550

1300

68

590

110/120

V301042

A130UD72TTI550

A130URD72TTI0550

630

1300

105

920

125

W301043

A130UD72TTI630

A130URD72TTI0630

700

1200

145

1040

140

X301044

A120UD72TTI700

A120URD72TTI0700

800

1200

215

1590

146

Y301045

A120UD72TTI800

A120URD72TTI0800

315

1300

12

102

84

Z301046

A130UD73TTI315

A130URD73TTI0315

350

1300

17

150

86

A301047

A130UD73TTI350

A130URD73TTI0350

400

1300

25

220

93

B301048

A130UD73TTI400

A130URD73TTI0400

450

1300

35

310

99/100

C301049

A130UD73TTI450

A130URD73TTI0450

500

1300

44

390

110/112

D301050

A130UD73TTI500

A130URD73TTI0500

550

1300

57

500

116/120

E301051

A130UD73TTI550

A130URD73TTI0550

630

1300

84

730

125/132

F301052

A130UD73TTI630

A130URD73TTI0630

700

1300

110

960

135/146

G301053

A130UD73TTI700

A130URD73TTI0700

800

1300

190

1630

148

H301054

A130UD73TTI800

A130URD73TTI0800

900

1300

250

2160

170

T1013903

A130UD73TTI900

A130URD73TTI0900

1000

1000

370

2430

152/174

K301056

A110UD73TTI1000

A110URD73TTI1000

1100

1000

445

2580

168/208

V302192

A110UD73TTI1100

A110URD73TTI1100

1250

1000

585

3480

186/200

M301058

A100UD73TTI1250

A100URD73TTI1250

1400

900

755

3880

210/228

N301059

A090UD73TTI1400

A090URD73TTI1400

1600

700

1430

5630

203

Q300877

A070UD73TTI1600

A070URD73TTI1600

1800

650

2040

7600

206

R300878

A065UD73TTI1800

A065URD73TTI1800

D

1300 Volt North American Style Ratings and Application Data, TTI Mounting

** Watts loss data is published for both blade and tapped style mounting configurations. When two watts loss values are shown this represents tapped/blade
values respectively.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D61

1250/1300 Volt PSC Square Body
1250/1300Volt, 2x72, 2x73 Semiconductor Protection Fuses
Size

73

2 X 72

2 X 73

Catalog No

New Description

Old Description

H300640

PC73UD13C315PP4

12,5URD73PPAF0315

J300641

PC73UD13C350PP4

12,5URD73PPAF0350

K300642

PC73UD13C405PP4

12,5URD73PPAF0400

L300643

PC73UD13C450PP4

12,5URD73PPAF0450

M300644

PC73UD13C500PP4

12,5URD73PPAF0500

N300645

PC73UD13C550PP4

12,5URD73PPAF0550

P300646

PC73UD13C630PP4

12,5URD73PPAF0630

Q300647

PC73UD13C700PP4

12,5URD73PPAF0700

R300648

PC73UD13C800PP4

12,5URD73PPAF0800

S300649

PC73UD12C900PP4

12URD73PPAF0900

T300650

PC73UD10C10CPP4

10URD73PPAF1000

V300651

PC73UD95V11CPP4

9,5URD73PPAF1100

T300719

PC73UD90V13CPP4

9URD73PPAF1250

V300720

PC73UD85V14CPP4

8,5URD73PPAF1400

W300721

PC272UD13C630TF

12,5URD272TTF0630

X300722

PC272UD13C700TF

12,5URD272TTF0700

Y300723

PC272UD13C800TF

12,5URD272TTF0800

Z300724

PC272UD13C900TF

12,5URD272TTF0900

A300725

PC272UD13C10CTF

12,5URD272TTF1000

B300726

PC272UD13C11CTF

12,5URD272TTF1100

M302231

PC272UD11C13CTF

11URD272TTF1250

D300728

PC272UD11C14CTF

11URD272TTF1400

L302230

PC272UD10C16CTF

10URD272TTF1600

E301994

PC272UD90V18CTF

9URD272TTF1800

F301995

PC272UD75V20CTF

7,5URD272TTF2000

G301996

PC272UD65V22CTF

6,5URD272TTF2200

H301997

PC272UD65V25CTF

6,5URD272TTF2500

F300730

PC273UD13C800TF

12,5URD273TTF0800

G300731

PC273UD13C900TF

12,5URD273TTF0900

H300732

PC273UD13C10CTF

12,5URD273TTF1000

J300733

PC273UD13C11CTF

12,5URD273TTF1100

K300734

PC273UD13C13CTF

12,5URD273TTF1250

K302229

PC273UD11C14CTF

11URD273TTF1400

J302228

PC273UD11C16CTF

11URD273TTF1600

S302236

PC273UD11C18CTF

11URD273TTF1800

P300738

PC273UD10C20CTF

10URD273TTF2000

Q300739

PC273UD95V22CTF

9,5URD273TTF2200

M301909

PC76UD95V22CP11

9,5URD273PLAF2200

R300740

PC76UD90V25CP11

9URD273PLAF2500

S300741

PC76UD85V28CP11

8,5URD273PLAF2800

K301999

PC76UD60V30CP11

6URD273PLAF3000

M302001

PC76UD60V32CP11

6URD273PLAF3200

N302002

PC76UD55V36CP11

5,5URD273PLAF3600

Weight (g)

1250

1750

1900

2600

2800

Microswitches and threaded studs supplied
separately (see pages J8)
2700

SIZE

A

B

C

D

E

F

G

H

J

K

d

e

L

M

N

2 X 72 TTF

60

138,5

172

11

91

65,5

100

35

66

39

M 10

4

131

48

72

2 X 73 TTF

74,5

167

200

13

91

79,6

114

50

80

39

M 12

4

131

54

86

Dimensions in / mm

D62

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

URB/URD/URL French Cylindrical
Protistor® fuses
600V AC URD from 0.10 up to 0.80A**
500V AC URB/URD/URL from 1 up to 30A
Size: 10 x 38mm

Features/Benefits:
•• Extremely high Interrupting rating

D

•• Protection of power semiconductors according to IEC 269.1 and 4
•• 500-600V AC
•• aR class according to VDE 636-23 and IEC 269.4
•• Without blown fuse indication according to NF C 63210 and 63211 - 0.10 up
to 0.80A**
•• With built in trip-indicator (1 up to 30A) Mersen Specialty*

Applications Data
Voltage
Rating

Class

UN(VAC)

Current

Melting I2t

Rating

@ 1 ms

IN (A)

I2tP (A2s)

Total Clearing I2t
@ UN I t t (A s)
2

2

Watts Loss
0.8 IN

IN

100 mA
125 mA
160 mA

1.2 10 -3
2.3 10 -3
5.2 10 -3

0.23
0.25
0.28

0.4
0.44
0.48

600 V

200 mA

8

0.34

0.58

without

250 mA

18

10 -3

0.35

0.60

315 mA

33

10 -3

0.42

0.73

400 mA

56

10 -3

0.46

0.80

500 mA
630 mA
800 mA
1A
1.25 A
1.6 A
2A
2.5 A
3.15 A
4A
5A
6A
8A
10 A
12 A
16 A
20 A
25 A
30 A

0.100
0.18
0.44
1.3
1.7
2.2
3.1
5.9
9
16
36
47
80
110
150
200
290
580
900

0.46
0.52
0.58
0.4
0.52
0.58
0.63
0.63
0.86
1.1
1.1
0.73
0.83
1
1.3
1.7
1.7
2.9
3.5

0.80
0.90
1
0.7
0.91
1
1.1
1.1
1.5
1.8
1.8
1.35
1.55
1.9
2.3
3.1
3.2
4.25
5.1

blown fuse

URD

indication

URD
500 V
with
tripindicator
URB

URL

0.49
0.13
0.31
0.65
1.65
2.80
5.30
12.7
1.3
2.3
3.6
5.25
9.30
16
37
58

10 -3

Tested
Interrupting
Rating

200 kA @ 600 V

50 kA @ 500 V

* minimum operating voltage for trip-indicator:20 V
** higher ratings 1 to 30 A see A070 gRB 30 T13

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D63

URB/URD/URL French Cylindrical
Catalog Numbers
Current Rating

Catalog No.

Ref. #

100 mA

A 060 URD 0.100 T13

H077632

125 mA

A 060 URD 0.125 T13

J077633

160 mA

A 060 URD 0.160 T13

K077634

200 mA

A 060 URD 0.200 T13

L077635

250 mA

A 060 URD 0.250 T13

M077636

315 mA

A 060 URD 0.315 T13

N077637

400 mA

A 060 URD 0.400 T13

P077638

500 mA

A 060 URD 0.500 T13*

Q077639

630 mA

A 060 URD 0.630 T13*

R077640

800 mA

A 060 URD 0.800 T13*

S077641

10.3x38 - Without blown fuse indicator

38.2mm

10.3mm

* UL Recognized

Catalog Numbers

D64

Current Rating

Catalog No.

Ref. #

1A

A 050 URD 001

T13 I

P076925

1.25A

A 050 URD 001.2

T13 I

H076597

1.6A

A 050 URD 001.6

T13 I

G076596

2A

A 050 URD 002

T13 I

Q076926

2.5A

A 050 URD 002.5

T13 I

F076595

3.15A

A 050 URD 003

T13 I

R076927

4A

A 050 URD 004

T13 I

S076928

5A

A 050 URD 005

T13 I

T076929

6A

A 050 URB 006

T13 I

V076930

8A

A 050 URB 008

T13 I

W076931

10A

A 050 URB 010

T13 I

X076932

12A

A 050 URB 012

T13 I

Y076933

16A

A 050 URB 016

T13 I

Z076034

20A

A 050 URB 020

T13 I

A076935

25A

A 050 URL 025

T13 I

B076936

30A

A 050 URL 030

T13 I

C076937

10.3x38 - With blown fuse trip-indicator

38.2mm

10.3mm

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

7mm

2.5mm

www.barr-thorp.com

URC/URD French Cylindrical
Protistor® fuses
690V AC
URC/URD from 6 up to 100A
Sizes: 14 x 51 & 22 X 58
Features/Benefits:
•• Extremely high Interrupting rating
•• Protection of power semiconductors according to IEC 269.1 and 4

D

•• 690V AC
•• aR class according to VDE 636-23 and IEC 269.4
•• Two models according to NF C 63210 and 63211 with and without blown
fuse built-in trip-indicator for sizes 14 x 51 and 22 x 58
•• UL recognized (except 6A)*

Applications Data
Voltage
Rating
UN (VAC)

Size
mm

14 x 51

Class

URC

690 V
URD

22 x 58
URD

Current

Melting I2t

Rating

@ 1 ms

IN (A)

I2tP (A2s)

6
8
10

1.3
2.4
4.3

12
16

Total Clearing
I2t @ UN

Watts Loss
0.8 IN

IN

17.5*
27.5
40

1.1
1.6
2

2
2.8
3.5

5.4

60

2.45

4.4

13.2

100

2.7

4.8

20

27

160

2.9

5.2

25

53

275

3.2

5.8

32
40 (1)
50 (1)

98
130
280

500
700
1500
7 IN < Ip < 30 IN

3.9
6
6.3

7
10.7
11.6

40 (2)
50 (2)
25
32
40
50
63
80
100

130
280
22
49
88
155
350
730
1560

6
6.3
5.2
5.7
6.8
7.8
8.4
9.4
10

10.7
11.6
10
11
13
14.9
16
17.8
19

I2t t (A 2s)

Ip ≥ 30 IN
850
1850
125
275
480
800
1850
3800
8000

700
1500

Tested
Interrupting
Rating

100 kA @ 690 V

* Without trip-indicator I2t : 15 A2s.
(1) No trip-indicator available for this model.
(2) Models available only with trip-indicator.
Minimum operating voltage for built-in trip-indicator:20 V.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D65

URC/URD French Cylindrical
Catalog Numbers
All the fuses presented on this page are UL Recognized (except 6 A)*

D66

6.900 CP URC 14.51/6*

K081475

6.900 CP URC 14.51/8

S093902

10 A

6.900 CP URC 14.51/10

T093903

12 A

6.900 CP URC 14.51/12

V093904

16 A

6.900 CP URC 14.51/16

W093905

20 A

6.900 CP URC 14.51/20

X093906

25 A

6.900 CP URC 14.51/25

Y093907

32 A

6.900 CP URC 14.51/32

Z093908

40 A

6.900 CP URC 14.51/40

A093909

50 A

6.900 CP URC 14.51/50

B093910

Current Rating

Description

Catalog No,

6A

6.921 CP URC 14.51/6*

G081518

8A

6.921 CP URC 14.51/8

C093911

10 A

6.921 CP URC 14.51/10

D093912

12 A

6.921 CP URC 14.51/12

E093913

16 A

6.921 CP URC 14.51/16

F093914

20 A

6.921 CP URC 14.51/20

G093915

25 A

6.921 CP URC 14.51/25

H093916

32 A

6.921 CP URC 14.51/32

J093917

40 A

6.921 CP URD 14.51/40

T100136

50 A

6.921 CP URD 14.51/50

V100137

Current Rating

Description

Catalog No,

25 A

6.900 CP URD 22x58/25

B093956

32 A

6.900 CP URD 22x58/32

Z094828

40 A

6.900 CP URD 22x58/40

S094822

50 A

6.900 CP URD 22x58/50

W094779

63 A

6.900 CP URD 22x58/63

T094823

80 A

6.900 CP URD 22x58/80

A094829

100 A

6.900 CP URD 22x58/100

Y094827

Current Rating

Description

Catalog No,

25 A

6.921 CP URD 22x58/ 25

H093801

32 A

6.921 CP URD 22x58/ 32

C093957

40 A

6.921 CP URD 22x58/ 40

J093802

50 A

6.921 CP URD 22x58/ 50

D093958

63 A

6.921 CP URD 22x58/ 63

K093803

80 A

6.921 CP URD 22x58/ 80

E093959

100 A

6.921 CP URD 22x58/100

F093960

51
14.3

6A
8A

14x51 - Without blown fuse indication (mm)

Weight : 18g
Packaging : 10 pieces

14x51 - With blown fuse trip-indicator (mm)

14.3

Catalog No,

Weight : 18g
Packaging : 10 pieces

22x58 - Without blown fuse indication (mm)

22.2

Description

Weight: 57 g
Packaging: 10 pieces

22x58 - With blown fuse trip-indicator (mm)

22.2

Current Rating

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Weight: 57 g
Packaging: 10 pieces

www.barr-thorp.com

URGD French Cylindrical
Protistor® Fuses
600V - 690V AC
URGD from 63 up to 250A
Sizes: 27 X 60mm
Features/Benefits:
•• Extremely high Interrupting rating
•• Protection of power semiconductors according to IEC 269.1 and 4

D

•• 600V-690V AC
•• aR class according to VDE 636-23 and IEC 269.4
•• Model according to NF C 63210 and 63211 with built-in blown fuse indication

Applications Data
Voltage
Rating
UN (VAC)

690 V

Rating

Melting I2t Total Clearing
I2t @ UN I2t t
@ 1 ms

IN (A)

I2tP (A2s)

63
80
100

405
860
1620

125
160

Current
Class

URGD

600 V

(A 2s)

Watts Loss
0.8 IN

IN

1840
3750
6800

12
13.5
15

22
24.6
27

3425

13600

16

29.5

6480

24600

17

32.5

200

13700

61500

18.5

35.7

250

29600

107000

21

40

Tested
Interrupting
Rating

200 kA @ 600 V

Minimum operating voltage for trip-indicator: 20 V

Catalog Numbers
Type

URGD

Voltage

690V

600V

Current Rating

Description

63 A
80 A

6,921 CP URGD 27x60/ 63
6,921 CP URGD 27x60/ 80

Catalog No.

A076820
B076821

100 A

6,921 CP URGD 27x60/100

C076822

125 A

6,921 CP URGD 27x60/125

D076823

160 A

6,921 CP URGD 27x60/160

E076824

200 A

6,921 CP URGD 27x60/200

F076825

250 A

6,921 CP URGD 27x60/250

W076264

27x60 - With blown fuse trip-indicator (mm)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D67

URB/URQ French Cylindrical
690V - 1000V AC
URB/URQ/URS from 32 up to 250A
Size: 27 X 60 mm
Features/Benefits:
•• Extremely high interrupting rating
•• Protection of power semiconductors according to IEC standard 269.1 and 4
•• 690V-1000V AC
•• aR class according to VDE 636-23 and IEC 269.4
•• Model according to NF C 63210 and 63211 with built-in blown trip-indicator
•• 690V URQ and 1000V URB are UL recognized

Applications Data
Voltage
Rating

Class

UN (VAC)

URQ
690 V

URS

1000 V

URB

Current

Melting I2t

Rating

@ 1 ms

IN (A)

I2tP (A2s)

50

110

63

155

80

Total Clearing
I2t @ UN I2t t

Watts Loss
0.81 IN

IN

610

8.4

16

860

11.1

21

350

1880

12.6

24

100

625

3210

14.2

27

125

1400

6970

15.7

30

160

3150

15000

17.7

34

200

6580

30000

19.4

38

250

15570

63000

22.6

45

125

2790

13000

14.5

25

160

5500

24000

17.5

30

32

33

250

7.4

14.5

40

60

450

8.7

17

50

110

840

9.7

19

63

200

1470

11.3

22

80

435

3300

12.3

24

100

975

6000

14

27

125

1910

12500

16

31

160

3890

26700

18

35

170

4710

36000

19

37

(A 2s)

Tested
Interrupting
Rating

200 kA @ 690 V

100 kA @ 1000 V

* Minimum operating voltage for trip-indicator: 20 V

D68

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

URB/URQ French Cylindrical
Catalog Numbers

URQ

URB

Voltage

690 V

1000 V

Current Rating

Description

50A
63 A

6,921 CP URQ 27x60/ 50
6,921 CP URQ 27x60/ 63

Catalog No.

N075958
V076309

80 A

6,921 CP URQ 27x60/ 80

W076310

100 A

6,921 CP URQ 27x60/100

R078330

125 A

6,921 CP URQ 27x60/125

S078331

160 A

6,921 CP URQ 27x60/160

X076311

200 A

6,921 CP URQ 27x60/200

T078332

250 A

6,921 CP URQ 27x60/250

T076308

32 A

1021 CP URB 27x60/ 32

S081298

40 A

1021 CP URB 27x60/ 40

R081297

50 A

1021 CP URB 27x60/ 50

Q081296

63 A

1021 CP URB 27x60/ 63

P081295

80 A

1021 CP URB 27x60/ 80

N081294

100 A

1021 CP URB 27x60/100

M081293

125 A

1021 CP URB 27x60/125

L081292

160 A

1021 CP URB 27x60/160

K081291

170 A

1021 CP URB 27x60/170

Z080338

D

Type

27x60 - With blown fuse trip-indicator (mm)

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D69

821cp gRB French Cylindrical
800V AC
gRB from 8 to 110A
SizeS: 27 X 60 mm
Features/Benefits:
•• Extremely high Interrupting rating
•• Protection of power semiconductors complying with IEC standards
269-1 and 4
•• 800V voltage rating according to IEC 33
•• gR Class as per IEC 269-4			
-Full range protection				
-Improved safety and protection			
-Allows selective coordination
•• With built in trip indicator

Applications Data
Voltage
Rating

Class

UN (V)

800

gRB

Current

Melting I2t

Rating

@ 1 ms

IN (A)

I2tP (A2s)

8

4.25

10

8.0

12

Total Clearing
I2t @ UN I2t t

Watts Loss

Tested
Interrupting

Catalog

Description

No

0.8 IN

IN

70

1.2

2.0

821 CP GRB27.60 8

R221436

100

1.3

2.3

821 CP GRB27.60 10

S221437

17.0

180

1.4

2.5

821 CP GRB27.60 12

T221438

16

26.5

250

1.9

3.5

175 kA

821 CP GRB27.60 16

V221439

20

38.5

350

2.4

4.0

@ 700 V

821 CP GRB27.60 20

W221440

25

73.0

600

2.8

5.0

821 CP GRB27.60 25

X221441

32

130

1000

3.5

6.0

821 CP GRB27.60 32

Y221442

40

195

1400

4.7

8.0

821 CP GRB27.60 40

Z221443

50

430

2700

4.8

8.5

90 kA

821 CP GRB27.60 50

A221444

63

965

5500

5.6

10

@ 800 V

821 CP GRB27.60 63

B221445

80

1890

11000

6.4

11.5

821 CP GRB27.60 80

C221446

100

3480

19000

7.4

13

821 CP GRB27.60 100

D221447

110

4670

27000

7.7

14

821 CP GRB27.60 110

E221448

(A 2s)

Rating

* Minimum operating voltage for trip-indicator: 20 V

Dimensions

D70

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Medium Voltage
Fuses & Accessories
Various types. Different configurations.
Many ratings. One solution.

Your problem:
need current limiting protection for
medium voltage

E
	

Medium Voltage Fuses .	
and Accessories

transformers and

Transformer Protection

distribution sys-

• Amp-Trap® CS-3 and

tems that supply
industrial plants,
shopping centers,

9F60/9F62 Series............................. E2
• Amp-Trap® & 9F62 Bolt-In Series.... E12

hospitals, schools, office buildings and underground

• Amp-Trap® CL-14 Series................. E16

residential service. On the other, you need high short-circuit cur-

Motor Protection

rent protection to avoid damages to busway, motors, switches
and other equipment.

• Amp-Trap® & 9F60 Series............... E21
• Amp-Trap® Bolt-in Series................. E27

Our solution: Current-limiting power fuses are widely used in

• Amp-Trap® DIN-style Series............ E30

these applications because they afford excellent over-current pro-

Potential Transformer Protection

tection and noiseless operation, and because they can be used
in confined spaces. The amount of damage in the faulted area
and the mechanical stress and strain on busway, switches and
other apparatus carrying the fault current is proportional to the
square of the current and to the length of time the fault persists.
By limiting the let through energy at the fault, properly applied

• Amp-Trap® & 9F60 Series
PT Fuses ........................................ E32
Capacitor Protection
• Amp-Trap® & 9F60 Series............... E36

current-limiting fuses assist in limiting or preventing short-circuit

Distribution Transformer Protection

damage to busway, circuit breakers, switches, and other electrical

• Sure Guard 9F59U Series ETP....... E44

components. Current-limiting power fuses are manufactured in

IEC Standard Back-up Fuse Links

ratings ranging from 1kV through 38 kV and in continuous current
ratings from 0.5 amperes through 1200 amperes. Various designs
are available for use with motors, transformers, capacitors, and
circuit-protection equipment.
Want more information fast? For more technical or application-

• IEC Standard Back-up
Fuse-Links....................................... E48
Accessories
• Type EK 9F61 Series...................... E53

specific information, please call our Medium Voltage experts, at
978-462-6662; 416-252-9371 in Canada; or visit our website at
us-ferrazshawmut.mersen.com.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E

On one hand you

Transformer Protection

Amp-Trap® CS-3 Series and 9F60/9F62 Series
2.75kV, 5.5kV, 8.25kV, 15.5kV, 25.8kV and 38kV
Ferrule Mounted Fuses
Mersen fuses for the protection of transformers and distribution lines deliver overload
and short circuit protection. These current-limiting fuses will melt at current that can
be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating.
These fuses are designed to withstand the transformer magnetizing inrush current.
They have 2 (size C), 3 (size D) and 4 (size E) inch diameter barrels with ferrules and
are mounted in spring reinforced clips.

Features/Benefits:
•• Amp-Trap CS-3 and 9F62 series are UL listed for compatibility with UL listed
equipment.
•• Ferrule mounting for standard clips and interchangeability with other brands of fuses.
•• Current-limiting for superior equipment protection.
•• Non-venting for silent operation
•• Metal embossed catalog number and manufacturing date for lasting identification.
•• Outdoor usage for the 9F62 and 9F60 type EJO.
•• Blown-fuse indicator to give positive identification of open fuse:

Ratings
•• See page E3 for listing

•• Amp-Trap: 2” Barrel 1 lb tripped force - 0.19 Inch
•• Amp-Trap: 3” Barrel 2 lb tripped force - 0.50 Inch
•• 9F60/9F62: 0.125 lb tripped force – 0.20 Inch
•• Accessories - see page E53

Highlights:

Applications:

•• E-Rated

•• Protection for 2.4kV to 34.5kV

•• UL listed

transformers or distribution

•• Outdoor use

systems.

Definitions:
General Purpose Current-Limiting Fuses (Per IEEE Std C37.40-2003):
A general purpose current-limiting fuse is one that is capable of interrupting all
currents from its rated interrupting current down to the current that causes melting

Approvals:
•• UL listed to standard File
E143362

of the fusible element(s) in one hour or more.
E-Rating: E-Rated fuses are general purpose fuses that operate as follow (Per ANSI
C37.46-2000):
•• 100E or less – must melt in 300 seconds (5 mins.) at 200 to 240% of E
(ampere) rating.
•• Over 100E – must melt in 600 seconds (10 mins.) at 220 to 264% of E
(ampere) rating.
•• Example: A 100E fuse must melt in 300 seconds with an applied current of 200
to 240 amperes.
Power Distribution Fuses:
Defines fuses designed prior to the time where the ANSI standards defined the term
“General Purpose” and do not meet all of the general purpose definition. These fuses
are capable of interrupting all currents above 2.2 to 3 times the fuse’s rated current up
to its maximum interrupting rating.

E2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Transformer Protection

Amp-Trap® CS-3 Series and 9F60/9F62 Series
Ferrule Mounted Fuses
Amp-Trap CS-3 Series: (Indoors or outdoors in a weatherproof enclosure)
A055F:	 5.5kV – AC: 5E to 450E – 63kA I.R. Sym
A825X:	 8.25kV – AC: 10E to 200E – 50kA I.R. Sym
A155F:	 15.5kV – AC: 5E to 200E – 50 kA I.R. Sym
9F62 Series Type EJO-1: (Indoors and outdoors)
9F62:	

5.5kV – AC: 25A to 450A – 50kA IR Sym

9F62:	

8.3kV – AC: 20A to 250A – 50 kA IR Sym

9F62:	

15.5kV – AC: 20A to 200A – 50 kA IR Sym

E

9F60 Series Type EJO-1: (Indoors and outdoors)
9F60:	

2.75kV – AC: 1E to 200E – 50kA IR Sym

9F60:	

5.5kV – AC: 0.5E to 200E – 50kA IR Sym

9F60:	

8.25kV – AC: 0.5E to 200E – 50kA IR Sym

9F60:	

15.5kV – AC: 0.5E to 100E – 50kA IR Sym

9F60:	

25.8kV – AC: 0.5E to 100E – 25kA to 35kA IR Sym

9F60:	

38kV – AC: 1E to 80E – 13kA to 26kA IR Sym

9F60 Series Type EJ-1: (Indoors or outdoors in a weatherproof enclosure)
9F60:	

2.75kV – AC: 1E to 200E – 47kA to 52kA IR Sym

9F60:	

5.5kV – AC: 0.5E to 25E – 63kA IR Sym

9F60:	

15.5kV – AC: 2E to 175E – 31kA to 50kA IR Sym

9F60:	

25.8kV – AC: 0.5E to 2E – 35kA IR Sym

9F series	

A = 3.31 inches (84mm)

9F series	

B = 6.16 inches (160mm)

Amp-Trap series A = 3.63 inches (92 mm)
Amp-Trap series B = 6.63 inches (169 mm)

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E3

Transformer Protection

Amp-Trap® CS-3 Series and 9F60/9F62 Series
2.75kV Ferrule mounted fuses:
2.75kV Power Distribution fuses – 9F60 series, E-Rated EJ-1
7” (178 mm) Clip Centers - Suitable for use indoors or in an enclosure only
Catalog No.

Amp Rating

9F60CCB001

1E

9F60CCB002

2E

9F60CCB003

3E

9F60CCB005

5E

9F60CCB007

7E

9F60CCB010

10E

9F60CCB015

15E

9F60CCB020

20E

9F60CCB025

25E

9F60ECB030

30E

9F60ECB040

40E

9F60ECB050

50E

9F60ECB065

65E

9F60ECB080

80E

9F60ECB100

100E

9F60GCB125

125E

9F60GCB150

150E

9F60GCB200

200E

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

Yes

2 (50.8)

9.18 (233)

2.75 kV

47kA

9F61AAB201

N/A

9F61AAB205

N/A

1

Yes

2 (50.8)

9.18 (233)

2.75 kV

52kA

9F61AAB201

N/A

9F61AAB205

N/A

1

Yes

3 (76.2)

10.88 (276)

2.75 kV

52kA

9F61AAB301

N/A

9F61AAB305

N/A

2

Yes

3 (76.2)

10.88 (276)

2.75 kV

52kA

9F61AAB401

N/A

9F61AAB405

N/A

No. of Barrels

Indicating

1

2.75kV Power Distribution fuses – 9F60 series, E-Rated EJ-1
9” (229 mm) Clip Centers - Suitable for use indoors or in an enclosure only
Catalog No.

Amp Rating

9F60CEB001

1E

9F60CEB002

2E

9F60CEB003

3E

9F60CEB005

5E

9F60CEB007

7E

9F60CEB010

10E

9F60CEB015

15E

9F60CEB020

20E

9F60CEB025

25E

No. of Barrels

Indicating

1

Yes

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

2 (50.8)

11.18 (284)

2.75 kV

52kA

9F61ACB201

N/A

9F61ACB205

N/A

2.75kV Power Distribution fuses – 9F60 Series, E-Rated EJO-1
12” (305 mm) Clip Centers - Suitable for use indoors or outdoors

E4

Catalog No

Amp Rating

9F60DJB001

1E

9F60DJB002

2E

9F60DJB003

3E

9F60DJB005

5E

9F60DJB007

7E

9F60DJB010

10E

9F60DJB015

15E

9F60DJB020

20E

9F60DJB025

25E

9F60FJB030

30E

9F60FJB040

40E

9F60FJB050

50E

9F60FJB065

65E

9F60FJB080

80E

9F60FJB100

100E

9F60HJB125

125E

9F60HJB150

150E

9F60HJB200

200E

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

Yes

2 (50.8)

14.18 (360)

2.75 kV

50kA

9F61AEG201

9F61CEF209

9F61AEG205

9F61CEF210

1

Yes

3 (76.2)

15.88 (403)

2.75 kV

50kA

9F61AEB301

9F61CEF309

9F61AEB305

9F61CEF310

2

Yes

3 (76.2)

15.88 (403)

2.75 kV

50kA

9F61AEB401

9F61CEF409

9F61AEB405

9F61CEF410

No. of Barrels

Indicating

1

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Transformer Protection

Amp-Trap® CS-3 Series and 9F60/9F62 Series
5.5kV Ferrule mounted fuses:
5.5kV Power Distribution fuses – 9F60 Series, E-Rated EJ-1
9” (229 mm) Clip Centers - Suitable for use indoors or in an enclosure only
Amp

No. of

Rating

Barrels

9F60CED905

0.5E

9F60CED001

1E

9F60CED002

2E

9F60CED003

3E

9F60CED005

5E

9F60CED007

7E

9F60CED010

10E

9F60CED015

15E

9F60CED020

20E

9F60CED025

25E

1

Indicating

Yes

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

2 (50.8)

11.18 (284)

5.5 kV

63kA

9F61ACB201

N/A

9F61ACB205

N/A

E

Catalog No.

5.5kV E-Rated Amp-Trap CS-3 Series – UL Listed
12” (305 mm) Clip Centers - Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Rating

Barrels

A055F1C0R0-5E

5E

A055F1C0R0-7E

7E

A055F1C0R0-10E

10E

A055F1C0R0-15E

15E

A055F1C0R0-20E

20E

A055F1C0R0-25E

25E

A055F1C0R0-30E

30E

A055F1C0R0-40E

40E

A055F1C0R0-50E

50E

A055F1C0R0-65E

65E

A055F1D0R0-10E

10E

A055F1D0R0-15E

15E

A055F1D0R0-20E

20E

A055F1D0R0-25E

25E

A055F1D0R0-30E

30E

A055F1D0R0-40E

40E

A055F1D0R0-50E

50E

A055F1D0R0-65E

65E

A055F1D0R0-80E

80E

A055F1D0R0-100E

100E

A055F1D0R0-125E

125E

A055F1D0R0-150E

150E

A055F1D0R0-175E

175E

A055F1D0R0-200E

200E

A055F2D0R0-250E

250E

A055F2D0R0-300E

300E

A055F2D0R0-350E

350E

A055F2D0R0-400E

400E

A055F2D0R0-450E

450E

Indicating

Diameter

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect Fuse Disconnect

Inches (mm) Inches (mm)

Length

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

1

Yes

2 (50.8)

14.18 (360)

5.5kV

63kA

9F61AEG201

N/A

9F61AEG205

N/A

1

Yes

3 (76.2)

15.88 (403)

5.5kV

63kA

9F61AEB301

N/A

9F61AEB305

N/A

2

Yes

3 (76.2)

15.88 (403)

5.5kV

63kA

–

N/A

–

N/A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E5

Transformer Protection

Amp-Trap® CS-3 Series and 9F60/9F62 Series
5.5.kV General Purpose fuses – 9F62 Series, EJO-1 – UL Listed
12” (305 mm) Clip Centers - Suitable for use indoors or outdoors
Catalog No.

Amp

No. of

Rating

Barrels

9F62HCB025

25A

9F62HCB030

30A

9F62HCB040

40A

9F62HCB050

50A

9F62HCB065

65A

9F62DCB080

80A

9F62DCB100

100A

9F62DCB125

125A

9F62DCB150

150A

9F62DCB175

175A

9F62DCB200

200A

9F62FCB250

250A

9F62FCB300

300A

9F62FCB350

350A

9F62FCB400

400A

9F62FCB450

450A

Indicating

Diameter
Inches (mm)

Length
Inches
(mm)

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

1

Yes

2 (50.8)

14.18 (360)

5.5 kV

50kA

9F61AEG201

9F61CEF209

9F61AEG205

9F61CEF210

1

Yes

3 (76.2)

15.88 (403)

5.5 kV

50kA

9F61AEB301

9F61CEF309

9F61AEB305

9F61CEF310

2

Yes

3 (76.2)

15.88 (403)

5.5 kV

50kA

9F61AEB401

9F61CEF409

9F61AEB405

9F61CEF410

5.5kV Power Distribution fuses – 9F60 Series, E-Rated EJO-1
12” (305 mm) Clip Centers - Suitable for use indoors or outdoors
Catalog No.

E6

Amp

No. of

Rating

Barrels

9F60DJD905

0.5E

9F60DJD001

1E

9F60DJD002

2E

9F60DJD003

3E

9F60DJD005

5E

9F60DJD007

7E

9F60DJD010

10E

9F60DJD015

15E

9F60DJD020

20E

9F60DJD025

25E

9F60FJD030

30E

9F60FJD040

40E

9F60FJD050

50E

9F60FJD065

65E

9F60FJD080

80E

9F60FJD100

100E

9F60HJD125

125E

9F60HJD150

150E

9F60HJD200

200E

Indicating

Diameter
Inches (mm)

Length
Inches
(mm)

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

1

Yes

2 (50.8)

14.18 (360)

5.5 kV

50kA

9F61AEG201

9F61CEF209

9F61AEG205

9F61CEF210

1

Yes

3 (76.2)

15.88 (403)

5.5 kV

50kA

9F61AEB301

9F61CEF309

9F61AEB305

9F61CEF310

2

Yes

3 (76.2)

15.88 (403)

5.5 kV

50kA

9F61AEB401

9F61CEF409

9F61AEB405

9F61CEF410

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Transformer Protection

Amp-Trap® CS-3 Series and 9F60/9F62 Series
8.25kV / 8.3kV Ferrule mounted fuses:
8.25kV E-Rated Amp-Trap CS-3 Series
12” (305 mm) Clip Centers - Suitable for use indoors or in an enclosure only
Amp

No. of

Rating

Barrels

A825X10E-1

10E

A825X15E-1

15E

A825X20E-1

20E

A825X25E-1

25E

A825X30E-1

30E

A825X40E-1

40E

A825X50E-1

50E

A825X65E-1

65E

A825X80E-1

80E

A825X100E-1

100E

A825X125E-1

125E

A825X150E-1

150E

A825X200E-1

200E

Indicating

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

1

Yes

3 (76.2)

15.88 (403)

8.25kV

50kA

9F61AEG301

N/A

9F61AEG305

N/A

2

Yes

3 (76.2)

15.88 (403)

8.25kV

50kA

–

N/A

–

N/A

E

Catalog No.

8.3kV General Purpose fuses – 9F62 Series, EJO-1 – UL Listed
12” (305 mm) Clip Centers - Suitable for use indoors or outdoors
Catalog No.

Amp

No. of

Rating

Barrels

9F62HCC020

20A

9F62HCC025

25A

9F62HCC030

30A

9F62HCC040

40A

9F62HCC050

50A

9F62DCC065

65A

9F62DCC080

80A

9F62DCC100

100A

9F62DCC125

125A

9F62DCC150

150A

9F62FCC175

175A

9F62FCC200

200A

9F62FCC250

250A

Indicating

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

1

Yes

2 (50.8)

14.18 (360)

8.3 kV

50kA

9F61AEG201

9F61CEF209

9F61AEG205

9F61CEF210

1

Yes

3 (76.2)

15.88 (403)

8.3 kV

50kA

9F61AEG301

9F61CEF309

9F61AEG305

9F61CEF310

2

Yes

3 (76.2)

15.88 (403)

8.3 kV

50kA

9F61AEG401

9F61CEF409

9F61AEG405

9F61CEF410

8.25kV Power Distribution fuses – 9F60 Series, E-Rated EJO-1
12” (305 mm) Clip Centers - Suitable for use indoors or outdoors
Catalog No.

Amp

No. of

Rating

Barrels

9F60DJE905

0.5E

9F60DJE001

1E

9F60DJE002

2E

9F60DJE003

3E

9F60DJE005

5E

9F60DJE007

7E

9F60DJE010

10E

9F60DJE015

15E

9F60FJE020

20E

9F60FJE025

25E

9F60FJE030

30E

9F60FJE040

40E

9F60FJE050

50E

9F60FJE065

65E

9F60FJE080

80E

9F60FJE100

100E

9F60HJE125

125E

9F60HJE150

150E

9F60HJE200

200E

Indicating

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

1

Yes

2 (50.8)

14.18 (360)

8.25 kV

50kA

9F61AEG201

9F61CEF209

9F61AEG205

9F61CEF210

1

Yes

3 (76.2)

15.88 (403)

8.25 kV

50kA

9F61AEG301

9F61CEF309

9F61AEG305

9F61CEF310

2

Yes

3 (76.2)

15.88 (403)

8.25 kV

50kA

9F61AEG401

9F61CEF409

9F61AEG405

9F61CEF410

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E7

Transformer Protection

Amp-Trap® CS-3 Series and 9F60/9F62 Series
15kV / 15.5kV Ferrule mounted fuses:
15.5kV Power Distribution fuses – 9F60 Series, E-Rated EJ-1
12” (305 mm) Clip Centers - Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Rating

Barrels

9F60CJH002

2E

9F60CJH003

3E

9F60CJH005

5E

9F60CJH007

7E

9F60CJH010

10E

1

Indicating

Yes

Diameter

Length

Inches

Inches

(mm)

(mm)

2 (50.8)

14.18 (360)

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

15.5 kV

50kA*

9F61AEG201

N/A

9F61AEG205

N/A

* These fuses were designed and originally tested at a higher maximum interrupting rating value. Consult factory for further information.

15.0kV Power Distribution fuses – 9F60 Series, E-Rated EJ-1
14” (356 mm) Clip Centers - Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Rating

Barrels

9F60KLH125

125E

9F60KLH150

150E

9F60KLH175

175E

2

Indicating

Yes

Diameter

Length

Inches

Inches

(mm)

(mm)

4 (101.6)

19.12 (486)

Max
Voltage

15.0 kV

Max IR
RMS
Sym

38kA

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

9F61AFG501 (13.8kV
nominal - 95 kV BIL)
9F61AFJ501 (14.4kV

N/A

nominal - 110kV BIL)

15.5kV Power Distribution fuses – 9F60 Series, E-Rated EJO-1
15” (381 mm) Clip Centers - Suitable for use indoors or outdoors
Catalog No.

Amp

No. of

Rating

Barrels

9F60DMH905

0.5E

9F60DMH001

1E

9F60DMH002

2E

9F60DMH003

3E

9F60DMH005

5E

9F60DMH007

7E

9F60DMH010

10E

9F60FMH015

15E

9F60FMH020

20E

9F60FMH025

25E

9F60FMH030

30E

9F60FMH040

40E

9F60FMH050

50E

9F60HMH065

65E

9F60HMH080

80E

9F60HMH100

100E

Indicating

Diameter

Length

Inches

Inches

(mm)

(mm)

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

1

Yes

2 (50.8)

17.2 (437)

15.5 kV

50kA*

9F61AGG201 (13.8kV
nominal - 95kV BIL)
9F61AGJ201 (14.4kV
nominal - 110kV BIL)

9F61CGL209

9F61AGG205 (13.8kV
nominal - 95kV BIL)
9F61AGJ205 (14.4kV
nominal - 110kV BIL)

9F61CGL210

1

Yes

3 (76.2)

18.88 (480)

15.5 kV

50kA

9F61AGG301 (13.8kV
nominal - 95kV BIL)
9F61AGJ301 (14.4kV
nominal - 110kV BIL)

9F61CGL309

9F61AGG305 (13.8kV
nominal - 95kV BIL)
9F61AGJ305 (14.4kV
nominal - 110kV BIL)

9F61CGL310

2

Yes

3 (76.2)

18.88 (480)

15.5 kV

50kA

9F61AGG401 (13.8kV
nominal - 95kV BIL)
9F61AGJ401 (14.4kV
nominal - 110kV BIL)

9F61CGL409

9F61AGG405 (13.8kV
nominal - 95kV BIL)
9F61AGJ405 (14.4kV
nominal - 110kV BIL)

9F61CGL410

* These fuses were designed and originally tested at a higher maximum interrupting rating value. Consult factory for further information.

E8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Transformer Protection

Amp-Trap® CS-3 Series and 9F60/9F62 Series
15.5kV General Purpose fuses – 9F62 Series, EJO-1 – UL Listed
15” (381 mm) Clip Centers - Suitable for use indoors or outdoors
Amp

No. of

Rating

Barrels

9F62HDD020

20A

9F62HDD025

25A

9F62HDD030

30A

9F62DDD050

50A

9F62DDD065

65A

9F62DDD080

80A

9F62DDD100

100A

9F62FDD125

125A

9F62FDD150

150A

9F62FDD175

175A

9F62FDD200

Indicating

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

9F61AGG201 (13.8kV
1

Yes

2 (50.8)

17.2 (437)

15.5 kV

50kA

nominal - 95kV BIL)
9F61AGJ201 (14.4kV

9F61AGG205 (13.8kV
9F61CGL209

nominal - 110kV BIL)

Yes

2

Yes

3 (76.2)

3 (76.2)

18.88 (480)

18.88 (480)

15.5 kV

15.5 kV

50kA

50kA

nominal - 95kV BIL)
9F61AGJ301 (14.4kV

nominal - 95kV BIL)
9F61AGJ305 (14.4kV

nominal - 110kV BIL)

nominal - 110kV BIL)

9F61AGG401 (13.8kV

9F61AGG405 (13.8kV

nominal - 95kV BIL)
9F61AGJ401 (14.4kV

9F61CGL210

9F61AGG305 (13.8kV
9F61CGL309

9F61CGL409

nominal - 110kV BIL)

200A

9F61AGJ205 (14.4kV
nominal - 110kV BIL)

9F61AGG301 (13.8kV
1

nominal - 95kV BIL)

nominal - 95kV BIL)
9F61AGJ405 (14.4kV

9F61CGL310

9F61CGL410

E

Catalog No.

nominal - 110kV BIL)

15.5kV E-Rated Amp-Trap CS-3 series – UL Listed
15” (381 mm) Clip Centers - Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Rating

Barrels

A155F1C0R0-5E

5E

A155F1C0R0-7E

7E

A155F1C0R0-10E

10E

A155F1C0R0-15E

15E

A155F1C0R0-20E

20E

A155F1C0R0-25E

25E

A155F1C0R0-30E

30E

A155F1D0R0-10E

10E

A155F1D0R0-15E

15E

A155F1D0R0-20E

20E

A155F1D0R0-25E

25E

A155F1D0R0-30E

30E

A155F1D0R0-40E

40E

A155F1D0R0-50E

50E

A155F2D0R0-65E

65E

A155F2D0R0-80E

80E

A155F2D0R0-100E

100E

Indicating

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

2 (50.8)

17.03 (433)

15.5kV

50kA

9F61AGG201 (13.8kV
1

Yes

nominal - 95kV BIL)
9F61AGJ201 (14.4kV

9F61AGG205 (13.8kV
nominal - 95kV BIL)

N/A

9F61AGJ205 (14.4kV

nominal - 110kV BIL)

9F61AGG301 (13.8kV
1

Yes

3 (76.2)

18.87 (479)

15.5kV

50kA

nominal - 95kV BIL)
9F61AGJ301 (14.4kV

9F61AGG305 (13.8kV
nominal - 95kV BIL)

N/A

9F61AGJ305 (14.4kV

nominal - 110kV BIL)

2

Yes

3 (76.2)

18.87 (479)

15.5kV

50kA

–

N/A

nominal - 110kV BIL)

N/A

nominal - 110kV BIL)

N/A

–

N/A

15.5kV E-Rated Amp-Trap CS-3 series – UL Listed
18” (457 mm) Clip Centers - Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Rating

Barrels

A155F1D0R0-65E

65E

A155F1D0R0-80E

80E

A155F1D0R0-100E

100E

A155F2D0R0-125E

125E

A155F2D0R0-150E

150E

A155F2D0R0-175E

175E

A155F2D0R0-200E

200E

Indicating

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

1

Yes

3 (76.2)

21.75 (552)

15.5kV

50kA

–

N/A

–

N/A

2

Yes

3 (76.2)

21.75 (552)

15.5kV

50kA

–

N/A

–

N/A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E9

Transformer Protection

Amp-Trap® CS-3 Series and 9F60/9F62 Series
25.8kV Ferrule mounted fuses:
25.8kV Power Distribution fuses – 9F60 Series, E-Rated EJ-1
15” (381 mm) Clip Centers - Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Rating

Barrels

9F60CMJ905

0.5E

9F60CMJ001

1E

9F60CMJ002

2E

1

Indicating

Yes

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

2 (50.8)

17.20 (437)

25.8 kV

35kA*

–

N/A

–

N/A

* These fuses were designed and originally tested at a higher maximum interrupting rating value. Consult factory for further information.

25.8kV Power Distribution fuses – 9F60 Series, E-Rated EJO-1
21” (533 mm) Clip Centers - Suitable for use indoors or outdoors
Catalog No.

Amp

No. of

Rating

Barrels

9F60DNJ905

0.5E

9F60DNJ001

1E

9F60DNJ002

2E

9F60DNJ003

3E

9F60DNJ005

5E

9F60DNJ007

7E

9F60DNJ010

10E

9F60FNJ015

15E

9F60FNJ020

20E

9F60FNJ025

25E

9F60FNJ030

30E

9F60FNJ040

40E

9F60FNJ050

50E

9F60HNJ065

65E

9F60HNJ080

80E

9F60HNJ100

100E

Indicating

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

1

Yes

2 (50.8)

23.18 (589)

25.8 kV

35kA*

9F61AHM201

9F61CHM209

9F61AHM205

9F61CHM210

1

Yes

3 (76.2)

24.81 (630)

25.8 kV

25kA

9F61AHM301

9F61CHM309

9F61AHM305

9F61CHM310

* These fuses were designed and originally tested at a higher maximum interrupting rating value. Consult factory for further information.

E10

2

Yes

3 (76.2)

24.81 (630)

25.8 kV

25kA

9F61AHM401

9F61CHM409

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

9F61AHM405

www.barr-thorp.com

9F61CHM410

Transformer Protection

Amp-Trap® CS-3 Series and 9F60/9F62 Series
38kV Ferrule mounted fuses:
38kV Power Distribution fuses – 9F60 Series, E-Rated EJO-1
27” (686 mm) Clip Centers - Suitable for use indoors or outdoors
Amp

No. of

Rating

Barrels

9F60FPK001

1E

9F60FPK002

2E

9F60FPK003

3E

9F60FPK005

5E

9F60FPK007

7E

9F60FPK010

10E

9F60FPK015

15E

9F60FPK020

20E

9F60FPK025

25E

9F60FPK030

30E

9F60FPK040

40E

9F60HPK050

50E

9F60HPK065

65E

9F60HPK080

80E

9F60FPT001

1E

9F60FPT002

2E

9F60FPT003

3E

9F60FPT005

5E

9F60FPT007

7E

9F60FPT010

10E

9F60FPT015

15E

9F60FPT020

20E

9F60FPT025

25E

9F60FPT030

30E

9F60FPT040

40E

9F60HPT050

50E

9F60HPT065

65E

9F60HPT080

80E

Indicating

Diameter

Length

Max

Max IR

Fuse Support

Fuse Support

Fuse Disconnect

Fuse Disconnect

Inches (mm)

Inches (mm)

Voltage

RMS Sym

Indoor (EK-1)

Outdoor (EK0-1)

Indoor (EK-3 )

Outdoor (EK0-3 )

1

Yes

3 (76.2)

30.81 (783)

38 kV

26kA*

–

9F61CJN309

–

9F61CJN310

1

Yes

3 (76.2)

30.81 (783)

38 kV

13kA

–

9F61CJN309

–

9F61CJN310

2

Yes

3 (76.2)

30.81 (783)

38 kV

13kA

–

9F61CJN409

–

9F61CJN410

1

No

3 (76.2)

30.81 (783)

38 kV

26kA*

–

9F61CJN309

–

9F61CJN310

1

No

3 (76.2)

30.81 (783)

38 kV

13kA

–

9F61CJN309

–

9F61CJN310

2

No

3 (76.2)

30.81 (783)

38 kV

13kA

–

9F61CJN409

–

9F61CJN410

E

Catalog No.

* These fuses were designed and originally tested at a higher maximum interrupting rating value. Consult factory for further information.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E11

Transformer Protection
Amp-Trap® and 9F62 Bolt-In Series
5.0kV, 5.5kV, 7.2kV, 8.25kV, and 15.5kV
Bolt-In fuses:
Mersen fuses for the protection of transformers and distribution lines deliver overload
and short circuit protection. These current-limiting fuses will melt at current that can
be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating.
These fuses are designed to withstand the transformer magnetizing inrush current.
They are single, double, triple or quadruple barrels 3 inch diameter (size D) with end
mounts designed for bolting directly to equipment bus or terminal pads.

Features/Benefits:
•• UL listed for compatibility with UL listed equipment.
•• Bolt-In mounting for direct connection to bus or terminals.
•• Current-limiting for superior equipment protection.
•• Non-venting for silent operation
•• Metal embossed catalog number and manufacturing date for lasting identification.
•• Outdoor usage for the 9F62.
•• Blown-fuse indicator to give positive identification of open fuse.
•• Amp trap: 2 lb tripped force - 0.50 Inch
•• 9F62: 0.125 lb tripped force – 0.20 Inch

Highlights:

Applications:

•• E-Rated

•• Protection for 5.5kV to 15.5kV

•• UL listed

transformers or distribution

•• Outdoor use

systems.

Definitions:
General Purpose Current-Limiting Fuses (Per IEEE Std C37.40-2003):
A general purpose current-limiting fuse is one that is capable of interrupting all
currents from its rated interrupting current down to the current that causes melting
of the fusible element(s) in one hour or more.
E-Rating: E-Rated fuses are general purpose fuses that operate as follows
(Per ANSI C37.46-2000):
•• 100E or less – must melt in 300 seconds (5 mins.) at 200 to 240% of E
(ampere) rating.
•• Over 100E – must melt in 600 seconds (10 mins.) at 220 to 264% of E
(ampere) rating.
•• Example: A 100E fuse must melt in 300 seconds with an applied current of 200
to 240 amperes.

Ratings:

Amp-Trap Bolt-in Series
A050B:
Volts	 : 5.0kV AC
Amps	 : 1200E
IR	
: 59kA Sym
A055B:
Volts	 : 5.5kV AC
Amps	 : 10 to 900E
: 59kA Sym
IR	
A072B:
Volts	 : 7.2kV AC
Amps	 : 250 to 400E
IR	
: 65kA Sym
A083B:
Volts	 : 8.25kV AC
Amps	 : 125 to 200E
IR	
: 50kA Sym
A155B:
Volts	 : 15.5kV AC
Amps	 : 200 to 300E
IR	
: 50kA Sym
9F62 Series Type EJO-1
9F62
Volts	 : 5.5kV AC
	
: 15.5V AC
Amps	 : 300 to 900A
IR	
: 50kA Sym

Approvals:
•• UL Listed to standard File
E143362

E12

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Transformer Protection
Amp-Trap® and 9F62 Bolt-In Series
5.0kV / 5.5kV Bolt-In fuses:
5.0kV E-Rated Amp-Trap Bolt-In Series
Suitable for use indoors or in an enclosure only
Catalog No.
A050B4D0R0-1200E

Amp

No. of

Rating

Barrels

1200E

4

Indicating
Yes

Figure E

Max

Max IR RMS

Voltage

Sym

5.0kV

59kA

Figure
E

5.5kV E-Rated Amp-Trap Bolt-In Series – UL Listed

Catalog Number

Amp

No. of

Rating

Barrels

A055B1DAR0-10E

10E

A055B1DAR0-15E

15E

A055B1DAR0-20E

20E

A055B1DAR0-25E

25E

A055B1DAR0-30E

30E

A055B1DAR0-40E

40E

A055B1DAR0-50E

50E

A055B1DAR0-65E

65E

A055B1DAR0-80E

80E

A055B1DAR0-100E

100E

A055B1DAR0-125E

125E

A055B1DAR0-150E

150E

A055B1DAR0-175E

175E

A055B1DAR0-200E

200E

A055B2DAR0-250E

250E

A055B2DAR0-300E

300E

A055B2DAR0-350E

350E

A055B2DAR0-400E

400E

A055B2DAR0-450E

450E

A055B2D0R0-450E

450E

A055B2D0R0-500E

500E

A055B2D0R0-600E

600E

A055B3D0R0-750E

750E

A055B3D0R0-900E

900E

Indicating

Max

Max IR RMS

Voltage

Sym

E

Suitable for use indoors or in an enclosure only
Figure

Figure A

1

Yes

5.5kV

63kA

A

2

Yes

5.5kV

63kA

B

Figure B
2

Yes

5.5kV

63kA

C

3

Yes

5.5kV

63kA

D

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E13

Transformer Protection
Amp-Trap® and 9F62 Bolt-In Series
5.5kV General Purpose fuses – 9F62 Series, EJO-1 – UL Listed
Suitable for use indoors or outdoors
Catalog No.

Amp Rating

9F62KCB500

500A

9F62KCB600

600A

9F62KCB700

700A

9F62KCB800

800A

9F62KCB900

900A

No. of Barrels

Indicating

Max Voltage

Max IR RMS Sym

Figure

4

Yes

5.5 kV

50kA

F

Fuse Support

Fuse Support Outdoor

Indoor (EK-1)

(EK0-1)

9F61AKB001

9F61CKF009

Figure C

Figure D

Figure F

E14

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Transformer Protection
Amp-Trap® and 9F62 Bolt-In Series
7.2kV / 8.25kV / 15.5kV Bolt-in fuses:

22.12
561.9mm
21.00
533.4mm

3.00
76.2mm

7.2kV E-Rated Amp-Trap Bolt-In Series

INDICATOR

Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Rating

Barrels

A072B2D0R0-250E

250E

A072B2D0R0-300E

300E

A072B2D0R0-350E

350E

A072B2D0R0-400E

400E

Indicating

7.63
193.7mm

Max

Max IR RMS

Voltage

Sym

7.9kV

65kA

Figure

Yes

2.13
54.0mm

2.05
52.2mm

23.73
602.7mm

2

Figure G

1.35
34.4mm

G

4.00
101.6mm

.44
11.1mm

1.50
38.1mm

E

8.25kV E-Rated Amp-Trap Bolt-In Series
Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Rating

Barrels

A083B2DAR0-125E

125E

A083B2DAR0-150E

150E

A083B2DAR0-175E

175E

A083B2DAR0-200E

200E

Indicating

Max

Max IR RMS

Voltage

Sym

4.00
101.6mm

7.63
193.7mm

INDICATOR

Figure
2.13
54.0mm

.25
6.4mm

2

Yes

8.25kV

50kA

3.00
76.2mm

H

.44 (11.1mm)
x .91 (23.1mm)
SLOTS

Figure H

1.53
38.9mm

15. 5kV E-Rated Amp-Trap Bolt-In Series
Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Indicating

Max

.44
11.1mm

Max IR RMS

1.53
38.8mm

Figure

Rating

Barrels

Voltage

Sym

A155B2D0R0-200E

200E

2

Yes

15.5kV

50kA

J

A155B3D0R0-300E

300E

3

Yes

15.5kV

50kA

K

.91
23.1mm
22.18
563.3mm

Ø 2.88
73.0mm

INDICATOR

7.63
193.7mm

4.00
101.6mm

2.13
54.0mm

3.00
76.2mm

20.99
533.2mm
23.73
602.7mm

Figure J

25.10
637.5mm

15.5kV General Purpose fuses – 9F62 Series, EJO-1 – UL Listed
Suitable for use indoors or outdoors
Catalog No.

Amp Rating

No. of Barrels

Indicating

Max Voltage

9F62KED300

300A

4

Yes

15.5 kV

Max IR RMS
Sym
50kA

Figure
L

Fuse Support

Fuse Support Outdoor

Indoor (EK-1)

(EK0-1)

9F61AHG001

9F61CHL009

INDICATOR

Figure L

.44 X .91
(11.1mm X 23.1mm)
4 SLOTS

Figure K

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E15

Transformer Protection
Amp-Trap® CL-14 Series
5.5kV, 8.25kV, and 15.5kV
Clip-lock mounted fuses:
Mersen Amp-Trap fuses for the protection of transformers and distribution lines
deliver overload and short circuit protection. These general purpose current-limiting
fuses will melt at current that can be as low as 1.7 times the fuse current ratings
up to its maximum interrupting rating. These fuses are designed to withstand the
transformer magnetizing inrush current. They are single, double or triple barrels 3
inch diameter (size D) and mount in unique cam-locking clips for superior connections
as well as easy installation and replacement.

Features/Benefits:
•• UL listed for compatibility with UL listed equipment.
•• Clip-lock mounting for reliable high integrity connection into circuit.
•• Current-limiting for superior equipment protection.
•• Non-venting for silent operation
•• Metal embossed catalog number and manufacturing date for lasting identification.
•• Blown-fuse indicator to give positive identification of open fuse.
•• 2 lb tripped force - 0.50 Inch

Highlights:

Applications:

•• E-Rated

•• Protection for 5.5kV to 15.5kV

•• UL listed

transformers or distribution
systems.

Definitions:
General Purpose Current-Limiting Fuses (Per IEEE Std C37.40-2003):
A general purpose current-limiting fuse is one that is capable of interrupting all
currents from its rated interrupting current down to the current that causes melting
of the fusible element(s) in one hour or more.
E-Rating: E-Rated fuses are general purpose fuses that operate as follows

Ratings:

Amp-Trap CL-14 Series
(Indoor or outdoors in a
weatherproof enclosure)
A055C
Volts	 : 5.5kV AC
Amps	 : 10 to 600E
IR	
: 63kA Sym
A083C:
Volts	 : 8.25kV AC
Amps	 : 60 to 200E
: 50kA Sym
IR	
A155C
Volts	 : 15.5kV AC
Amps	 : 10 to 300E
IR	
: 50kA Sym

Approvals:
•• UL Listed to standard File
E143362

(Per ANSI C37.46-2000):
•• 100E or less – must melt in 300 seconds (5 mins.) at 200 to 240% of E
(ampere) rating.
•• Over 100E – must melt in 600 seconds (10 mins.) at 220 to 264% of E
(ampere) rating.
•• Example: A 100E fuse must melt in 300 seconds with an applied current of 200
to 240 amperes.

E16

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Transformer Protection
Amp-Trap® CL-14 Series
Clip-lock clips for CL-14 fuses:
228-700-520 (One pair of clips)
The clip lock design provides a reliable, high-pressure contact. Mersen CL-14 fuses
have copper tabs which slide into position between the clip casting and cam. When
the cam is locked by moving the pull ring, a high-pressure contact is made between
the clip casting and fuse tab. Each clip includes two .44” diameter counter-sunk holes
on 2” centers and two flat head socket screws (3/8-16 UNRC, recommended torque
200 pound-inches) for mounting the clip on standard NEMA insulators. Order catalog
number 228-700-520 (for one pair of fuse clips, enough for one fuse).

CL-14 Fuse

A

Catalog No.

Dimensions - Inches

A055C1DORO-(10E-150E)

13.25

A055C1DORO-(200E-400E)

19.25

A055C2DORO-(450E-600E)

19.25

A155C1DORO-(10E-50E)

16.25

A155C1DORO-(65E-100E)

19.25

A155C2DORO-(125E)

19.25

A155C3DORO-(150E-300E)

19.25

E

Catalog
Numbers, Dimensions
	

Mounting Details for Clip Lock Cat. No. 228-700-520

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E17

Transformer Protection
Amp-Trap® CL-14 Series

5.5kV / 8.25kV Clip-lock mounted fuses:
5.5kV E-Rated Amp-Trap CL-14 Series
15.25 (388mm) Clip Centers (dimension E). Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Rating

Barrels

A055C1D0R0-10E

10E

A055C1D0R0-15E

15E

A055C1D0R0-20E

20E

A055C1D0R0-25E

25E

A055C1D0R0-30E

30E

A055C1D0R0-40E

40E

A055C1D0R0-50E

50E

A055C1D0R0-65E

65E

A055C1D0R0-80E

80E

A055C1D0R0-100E

100E

A055C1D0R0-125E

125E

A055C1D0R0-150E

150E

Indicating

Max

Max IR RMS

Voltage

Sym

Figure

Dimensions Inches (mm)
A

B

C

E

0.5
1

Yes

5.5kV

63kA

A

16.81

16.12

(427)

(410)

(13)
Tripped
Force

15.25
(388)

2 lbs.

5.5kV E-Rated Amp-Trap CL-14 Series
21.25 (540mm) Clip Centers (dimension E). Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Rating

Barrels

A055C1D0R0-200E

200E

A055C1D0R0-250E

250E

A055C1D0R0-300E

300E

A055C1D0R0-400E

400E

A055C2D0R0-450E

450E

A055C2D0R0-500E

500E

A055C2D0R0-600E

600E

1

2

Indicating

Yes

Yes

Max

Max IR RMS

Voltage

Sym

5.5kV

63kA

5.5kV

63kA

Figure

A

B

Dimensions Inches (mm)
A

B

22.81

22.12

(580)

(562)

22.81

22.12

(580)

(562)

C
0.5 (13)
Tripped
Force 2 lbs.
0.5 (13)
Tripped
Force 2 lbs.

E

21.25
(540)

21.25
(540)

Figure B
Figure A

Blown-fuse Indicator

E18

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Transformer Protection
Amp-Trap® CL-14 Series
8.25kV E-Rated Amp-Trap CL-14 Series
15.70 (399mm) and 15.39 (391mm) Clip Centers (dimension E). Suitable for use indoors or in an enclosure only
Catalog No.

A083C1D0R0-60E

A083C2D0R0-200E

Amp

No. of

Rating

Barrels

60E

1

200E

2

Indicating

Yes

Yes

Max

Max IR RMS

Voltage

Sym

8.25kV

8.25kV

50kA

50kA

Figure

A

B

Dimensions Inches (mm)
A

B

16.95

16.26

(431)

(413)

16.95

16.26

(431)

(413)

C
0.5 (13)
Tripped Force
2 lbs.
0.5 (13)
Tripped Force
2 lbs.

E
15.39
(391)
15.39
(391)

Figure B

E

Figure A

Blown-fuse Indicator

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E19

Transformer Protection
Amp-Trap® CL-14 Series
15.5kV Clip-lock mounted fuses:
15.5kV E-Rated Amp-Trap CL-14 Series
18.25 (464mm) Clip Centers (dimension E). Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Rating

Barrels

A155C1D0R0-10E

10E

A155C1D0R0-15E

15E

A155C1D0R0-20E

20E

A155C1D0R0-25E

25E

A155C1D0R0-30E

30E

A155C1D0R0-40E

40E

A155C1D0R0-50E

50E

Indicating

Max

Max IR RMS

Voltage

Sym

Figure

Dimensions Inches (mm)
A

B

C

E

0.5
1

Yes

15.5kV

50kA

A

19.81

19.12

(504)

(486)

(13)
Tripped
Force

18.25
(464)

2 lbs.

15.5kV E-Rated Amp-Trap CL-14 Series
21.25 (540mm) Clip Centers (dimension E). Suitable for use indoors or in an enclosure only
Catalog No.

Amp

No. of

Rating

Barrels

A155C1D0R0-65E

65E

A155C1D0R0-80E

80E

A155C1D0R0-100E

100E

A155C2D0R0-125E

125E

A155C2D0R0-150E

150E

A155C2D0R0-200E

200E

A155C3D0R0-150E

150E

A155C3D0R0-200E

200E

A155C3D0R0-250E

250E

A155C3D0R0-300E

300E

1

2

3

Indicating

Yes

Yes

Yes

Max

Max IR RMS

Voltage

Sym

15.5kV

15.5kV

15.5kV

50kA

50kA

50kA

Figure

A

B

C

Dimensions Inches (mm)
A

B

22.81

22.12

(580)

(562)

22.81

22.12

(580)

(562)

22.81

22.12

(580)

(562)

C
0.5 (13)
Tripped
Force 2 lbs.
0.5 (13)
Tripped
Force 2 lbs.
0.5 (13)
Tripped
Force 2 lbs.

E
21.25
(540)

21.25
(540)

21.25
(540)

Blown-fuse Indicator

Figure A

E20

Figure B

Figure C

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Motor Protection
Amp-Trap® and 9F60 Series

2.4kV, 2.54kV, 4.8kV, 5.08kV and 7.2kV
Ferrule mounted fuses:
Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended
for the short circuit protection of medium voltage motors and motor controllers.
R-Rated fuses are back-up fuses that have a minimum interrupting rating, and must
be coordinated with overload relays in combination motor starters. The motor starter
manufacturer generally specifies the R-Rated fuse size. These fuses come with a 3
(size D) or 4 (size E) inch diameter barrels with ferrules and are mounted in spring
reinforced clips.

Features/Benefits:
E

•• The Amp-Trap and 9F60 R-Rated fuses are UL Recognized.
•• Ferrule mounting for standard clips and interchangeability with other brands
of fuses.
•• Current-limiting for superior equipment protection.
•• Metal embossed catalog number and manufacturing date for lasting identification.
•• Hookeye for non load-break isolation by hookstick
•• On the 4.8kV an optional hookeye mounted in the factory is available.
•• On all other 3” barrel if a hookeye is required, use the operating eye
9F61AAW612. (See page E58)
•• Blown-fuse indicator to give positive identification of open fuse.
•• Amp trap: 3” Barrel 2 lb tripped force - 0.50 Inch
•• 9F60: 0.125 lb tripped force – 0.20 Inch

Highlights:

Applications:

•• R-Rated

•• Short circuit protection of medium

•• UL recognized

voltage motors and motor
controllers.

Definitions:
R-Rating: R-Rated fuses are back-up fuses that operate as follows (Per ANSI
C37.46-2000): An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of
current equal to 100 times the “R” rating.

Ratings:

Amp-Trap
A240R
Volts	 : 2.4kV AC
Amps	 : 1 to 36R
IR	
: 65kA Sym
A480R
Volts	 : 4.8kV AC
Amps	 : 2 to 36R
: 50kA Sym
IR	
A072F
Volts	 : 7.2kV AC
Amps	 : 2 to 24R
IR	
: 50kA Sym
9F60 SERIES TYPE EJ-2
9F60
Volts	 : 2.54kV AC
	
: 5.08kV ac
Amps	 : 2 to 36R
IR	
: 50kA Sym

Approvals:
Back-up Current-Limiting Fuses: A back-up current-limiting fuse is a fuse that can
interrupt any current between its rated minimum interrupting current and its maximum
interrupting current. Back-up fuses are not designed or intended to open under

•• Amp-Trap: UL File E93367
•• 9F60: UL File E191980

overload conditions.
Continuous Ampere Rating at 40°C: The continuous amp rating defines the thermal
capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse
selection.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E21

Motor Protection
Amp-Trap® and 9F60 Series
2.4kV R-Rated Amp-Trap Series
7.5” (191 mm) Clip Centers – Barrel diameter size D (3”)
Minimum

Continuous
Catalog No.

Size

Interrupting

Amp rating

Rating

at 40°C

RMS Amp

A240R1R

1R

35

100

A240R2R

2R

70

170

A240R3R

3R

100

250

A240R4R

4R

130

340

A240R5R

5R

150

420

A240R6R

6R

170

500

A240R9R

9R

200

760

A240R12R

12R

230

1000

A240R18R

18R

390

1500

A240R24R

24R

450

2000

A240R36R

36R**

650

2900

1 Phase interrupting rating

Dimension

No
of

Fig.

Indicating

Barrels

1

L

UL Component

Inches

Recognition

(mm)

Max IR RMS Sym

Max IR RMS Sym

10.88 276)

65kA at 2.6kV

65kA at 2.6kV

Max Voltage Tested

A
Yes

2

B

3

C

** Not recommended for use in fuse clips which grasp only one barrel.
2.4kV / 2.54kV Ferrule mounted fuses:
Indicator Flush with Surface
2 Lb. Force (Tripped)

0.5
(12.7)

0.5
(12.7)

3.312
(84.1)

3.312
(84.1)

0.5
.5 (12.7)
(12.7)

3.312
(84.1)

3
(76)

L

3
(76)

Figure A

E22

L

3
(76)

3
(76)

Figure B

L

3
(76)

3
(76)

3
(76)

Figure C

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Motor Protection
Amp-Trap® and 9F60 Series
2.4kV R-Rated 9F60 EJ-2 Series
7” (179 mm) Clip Centers – Barrel diameter size D (3”)

Catalog No.

Size

Amp rating
at 40°C

9F60LCB502

2R

70

Minimum
Interrupting
Rating
RMS Amp

Dimension

No
of

Fig.

1 Phase interrupting rating

L

UL Component

Inches

Recognition

(mm)

Max IR RMS Sym

Max IR RMS Sym

Yes

10.88 276)

50kA at 2.54kV

50kA at 2.54kV

No

10.88 (276)

50kA at 2.54kV

50kA at 2.54kV

Indicating

Barrels

Max Voltage Tested

195

9F60LCB503

3R

100

270

9F60LCB504

4R

130

370

9F60LCB506

6R

170

580

9F60LCB509

9R

200

820

9F60LCB512

12R

230

1150

9F60MCB518

18R

390

1800

9F60MCB524

24R

450

2400

9F60LCL302

2R

70

195

9F60LCL303

3R

100

270

9F60LCL304

4R

130

370

9F60LCL306

6R

170

580

9F60LCL309

9R

200

820

9F60LCL312

12R

230

1150

9F60MCL318

18R

390

1800

9F60MCL324

24R

450

2400

1

D

2

E

1

D

2

E

Continuous

E

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E23

Motor Protection
Amp-Trap® and 9F60 Series

4.8kV / 5.08kV Ferrule Mounted Fuses:
4.8kV R-Rated Amp-Trap Series
12.5” (317 mm) Clip Centers – Barrel diameter size D (3”)
Minimum

Continuous
Catalog No.

Size

Interrupting

Amp rating

Rating

at 40°C
A480R2R-1

2R

70

of

Fig.

Indicating

Barrels

RMS Amp

1 Phase interrupting rating

Dimension

No

L

UL Component

Inches

Recognition

(mm)

Max IR RMS Sym

Max IR RMS Sym

15.88 (403)

64kA at 5.5kV

64kA at 5.5kV

Max Voltage Tested

190

A480R3R-1

3R

100

225

A480R4R-1

4R

130

330

A480R5R-1

5R

150

400

A480R6R-1

6R

170

500

A480R9R-1

9R

200

740

A480R12R-1

12R

230

955

A480R18R-1

18R

390

1440

A480R24R-1

24R

450

1910

A480R36R-1

36R**

650

2810

1

A
Yes

2

B

3

C

4.8kV R-Rated Amp-Trap Series with Hookeye
12.75” (324 mm) Clip Centers – Barrel diameter size D (3”)
Minimum

Continuous
Catalog No.

Size

Interrupting

Amp rating

Rating

at 40°C
A480R2R-1HE

2R

A480R3R-1HE

3R

100

225

4R

130

330

A480R5R-1HE

5R

150

400

A480R6R-1HE

6R

170

500

A480R9R-1HE

9R

200

740

A480R12R-1HE

12R

230

955

A480R18R-1HE

18R

390

1440

A480R24R-1HE

24R

450

1910

3.312
(84.1)

0.5
(12.7)

1

Indicating

UL Component

Inches

Recognition

(mm)

Max IR RMS Sym

Max IR RMS Sym

16.13 (410)

50kA at 5.08kV

63kA at 5.5kV

Max Voltage Tested

A
Yes

2

B

3.312
(84.1)

0.5
(12.7)

3.312
(84.1)

0.5
(12.7)

L

L

E24

Fig.

L

190

A480R4R-1HE

3

3

3

(76)

(76)

(76)

Figure A

of
Barrels

RMS Amp

70

1 Phase interrupting rating

Dimension

No

Figure B

L

3
(76)

3

3

(76)

(76)

Figure C

0.34 Dia. Typ.
(8)

Blown-fuse Indicator
(Tripped Position)

1.0
(25.4)

Hookeye

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Motor Protection
Amp-Trap® and 9F60 Series

5.08kV R-Rated 9F60 EJ-2 Series
12” (305 mm) Clip Centers – Barrel diameter size D (3”)

Catalog No.

Size

Amp rating
at 40°C

9F60LJD502

2R

70

Minimum
Interrupting
Rating
RMS Amp

of

1 Phase interrupting rating

Dimension

No
Fig.

L

UL Component

Inches

Recognition

(mm)

Max IR RMS Sym

Max IR RMS Sym

Yes

15.97 (406)

50kA at 5.08kV

50kA at 5.08kV

No

15.97 (406)

50kA at 5.08kV

50kA at 5.08kV

Indicating

Barrels

Max Voltage Tested

195

9F60LJD503

3R

100

270

9F60LJD504

4R

130

370

9F60LJD506

6R

170

580

9F60LJD509

9R

200

820

9F60LJD512

12R

230

1150

9F60MJD518

18R

390

1800

9F60MJD524

24R

450

2400

9F60LJN302

2R

70

195

9F60LJN303

3R

100

270

9F60LJN304

4R

130

370

9F60LJN306

6R

170

580

9F60LJN309

9R

200

820

9F60LJN312

12R

230

1150

9F60MJN318

18R

390

1800

9F60MJN324

24R

450

2400

1

D*

2

E*

1

D*

2

E

Continuous

E*

* Figures D & E are on page E23

5.08kV R-Rated 9F60 EJ-2 Series
14” (356 mm) Clip Centers – Barrel diameter size E (4”) – Use clip parts 9F61BNW452
Continuous
Catalog No.

Size

Amp rating
at 40°C

1 Phase interrupting rating

Minimum

Dimension

Interrupting

L

UL Component

Inches

Recognition

(mm)

Max IR RMS Sym

Max IR RMS Sym

19.12 (486)

50kA at 5.08kV

50kA at 5.08kV

Rating

Indicating

RMS Amp

9F60NLD830

30R

550

3600

9F60NLD836

36R

650

4200

Yes

Max Voltage Tested

No
of

2

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fig.

Barrels

F

E25

Motor Protection
Amp-Trap® and 9F60 Series
7.2kV Ferrule Mounted Fuses:
7.2kV R-Rated Amp-Trap Series
12.5” (317 mm) Clip Centers – Barrel diameter size D (3”)
Continuous
Catalog No.

Size

Amp rating
at 40°C

Minimum

of

Rating

2R

70

190

A072F1D0R0-3R

3R

100

225

A072F1D0R0-4R

4R

130

330

A072F1D0R0-5R

5R

150

400

A072F1D0R0-6R

6R

170

500

A072F1D0R0-9R

9R

200

740

A072F1D0R0-12R

12R

230

955

A072F2D0R0-18R

18R

390

1440

A072F2D0R0-24R

24R

450

1910

Fig.

Indicating

Barrels

RMS Amp

A072F1D0R0-2R

Indicator Flush with Surface
2 Lb. Force (Tripped)

No

Interrupting

1

1 Phase interrupting rating

L

UL Component

Inches

Recognition

(mm)

Max IR RMS Sym

Max IR RMS Sym

15.88 (403)

50kA at 7.2kV

50kA at 7.7kV

2

B

0.5
(12.7)

3.312
(84.1)

3
(76)

L

Figure A

E26

L

3
(76)

3
(76)

Max Voltage Tested

A
Yes

0.5
(12.7)

Dimension

3
(76)

Figure B

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Motor Protection
Amp-Trap® Bolt-In Series
5.08kV, 7.2kV and 15.5kV
Bolt-In fuses:
Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended
for the short circuit protection of medium voltage motors and motor controllers.
R-Rated fuses are back-up fuses that have a minimum interrupting rating, and must
be coordinated with overload relays in combination motor starters. The motor starter
manufacturer generally specifies the R-Rated fuse size. These fuses are single,
double, triple or quadruple barrels 3 inches diameter with end mounts designed for
bolting directly to equipment bus or terminal pads.

Features/Benefits:
E

•• The Amp-Trap Bolt-in series are UL Recognized.
•• Bolt-in mounting for direct connection to bus or terminals.
•• Current-limiting for superior equipment protection.
•• Metal embossed catalog number and manufacturing date for lasting identification.
•• Blown-fuse indicator to give positive identification of open fuse.

Ratings:
Amp-Trap

Amp-Trap: 3” Barrel 2 lb tripped force - 0.50 Inch

A051B
Volts	

Highlights:

Applications:

•• R-Rated

•• Short circuit protection of medium

IR	

: 65kA Sym

A072B

voltage motors and motor

•• UL recognized

: 5.08kV AC

Amps	 : 2 to 38R

Volts	

controllers.

: 7.2kV AC

Amps	 : 2 to 24R

Definitions:

	

: 19R to 57X

R-Rating: R-Rated fuses are back-up fuses that operate as follows (Per ANSI

IR	

: 50kA Sym

C37.46-2000): An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of

	

: 65kA Sym

current equal to 100 times the “R” rating.
A155B
Back-up Current-Limiting Fuses: A back-up current-limiting fuse is a fuse that can

Volts	

interrupt any current between its rated minimum interrupting current and its maximum

Amps	 : 9 to 38X

interrupting current. Back-up fuses are not designed or intended to open under

IR	

: 15.5kV AC
: 50kA Sym

overload conditions.
Continuous Ampere Rating at 40°C: The continuous amp rating defines the
thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in

Approvals:
•• UL Recognized File E93367

fuse selection.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E27

Motor Protection
Amp-Trap® Bolt-In Series
5.08kV / 7.2kV Bolt-In fuses:
5.08kV R-Rated Amp-Trap Bolt-In Series
Continuous
Catalog No.

Size

Amp rating
at 40°C

A051B1DAR0-2R

2R

70

Minimum
Interrupting
Rating
RMS Amp

1 Phase interrupting rating

No
of

Fig.

Indicating

Barrels

UL Component
Recognition

Max Voltage Tested

Max IR RMS Sym

Max IR RMS Sym

65kA at 5.08kV

65kA at 5.5kV

50kA at 5.08kV

50kA at 5.2kV

190

A051B1DAR0-3R

3R

100

225

A051B1DAR0-4R

4R

130

330

A051B1DAR0-6R

6R

170

500

A051B1DAR0-9R

9R

200

740

A051B1DAR0-12R

12R

230

955

1

A051B2DAR0-18R

18R

390

1440

A051B2DAR0-24R

24R

450

1910

A051B2DAR0-32R

32R

600

2500

A051B2DAR0-38R

38R

700

3100

A051B3DAR0-48X

48X

750

3600

A051B3DAR0-57X

57X

900

4500

A

Yes

2

B

Yes

3

C

Yes

7.2kV R-Rated Amp-Trap Bolt-In Series
Continuous
Catalog No.

Size

Amp rating
at 40°C

A072B1DAR0-2R

2R

70

Minimum
Interrupting
Rating
RMS Amp

1 Phase interrupting rating

No
of

Fig.

Indicating

Barrels

UL Component
Recognition

Max Voltage Tested

Max IR RMS Sym

Max IR RMS Sym

50kA at 7.2kV

50kA at 7.7kV

190

A072B1DAR0-3R

3R

100

225

A072B1DAR0-4R

4R

130

330

A072B1DAR0-5R

5R

150

400

A072B1DAR0-6R

6R

170

500

A072B1DAR0-9R

9R

200

740

A072B1DAR0-12R

12R

230

955

1

A
Yes

A072B2DAR0-18R

18R

390

1440

A072B2DAR0-24R

24R

450

1910

2

B

3.00
76.2mm

11.63
295.3mm

4.00
101.6mm
INDICATOR

Figure A
2.05
52.2mm

1.38
34.9mm

Figure C

.44
(11.1mm
x .91
23.1mm)
SLOTS

Figure B

E28

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Motor Protection
Amp-Trap® Bolt-In Series
7.2kV / 15.5kV Bolt-In fuses:
7.2kV R-Rated Amp-Trap Bolt-In Series
Continuous
Catalog No.

Size

Amp rating
at 40°C

1 Phase interrupting rating

Minimum
Interrupting
Rating

Indicating

RMS Amp

A072B1D0R0-19R

19R

300

1560

A072B2D0R0-32R

32R

540

3070

A072B2D0R0-38R

38R

600

3480

A072B3DBR0-48X

48X

750

A072B3DBR0-57X

57X

900

UL Component

No

Max Voltage Tested

Recognition
Max IR RMS Sym

of

Fig.

Barrels

Max IR RMS Sym
65kA at 7.5kV

1

D

65kA at 7.66kV

2

E

4360

65kA at 7.66kV

3

F

5000

65kA at 7.2kV

3

F

Yes

65kA at 7.2kV

E

15.5kV R-Rated Amp-Trap Bolt-In Series
1 Phase interrupting rating
Continuous
Catalog No.

Size

Amp rating
at 40°C

UL Component

Minimum
Interrupting
Rating
RMS Amp

A155B2D0R0-9R

9R

200

888

A155B2D0R0-12R

12R

230

1200

A155B3D0R0-18X

18X

390

1900

A155B3D0R0-24X

24X

450

2633

A155B4D0R0-32X

32X

600

3510

A155B4D0R0-38X

38X

700

4000

Max Voltage Tested

Recognition

No
of

Indicating
Max IR RMS Sym

Yes

Max IR RMS Sym

50 kA at 15.5kV

Fig.

Barrels

50 kA at 15.5kV

2

G

3

H

4

J

22.18
563.4mm

INDICATOR

INDICATOR

7.63
193.7mm

4.00
101.6mm

.25
6.4mm

2.13
54.0mm
21.00
533.3mm

Ø 2.88
73.0mm
3.00
76.2mm

23.74
602.9mm

Figure D

.91
23.1mm

Figure G

1.53
38.8mm

.44
11.1mm

22.43
569.8mm

INDICATOR

INDICATOR

7.63
193.7mm

4.00
101.6mm

6.13
155.6mm
2.13
54.0mm

11.63
295.3mm

.25
6.4mm

4.00
101.6mm
.38
9.5mm

3.00
76.2mm

21.00
533.3mm

2.13
54.0mm

25.10
637.5mm

1.53
38.8mm

.91
23.1mm

1.53
38.8mm

Figure E

Ø 2.88
73.0mm
3.00
76.2mm

23.74
602.9mm

Figure H

.44
11.1mm

INDICATOR

22.43
569.8mm

4.00
101.6mm

INDICATOR

7.63
193.8mm

4.00
101.6mm

2.13
54.0mm
21.00
533.3mm
Ø 2.88
73.0mm

23.74
602.9mm

.44 X .91
(11.1mmX23.1mm)
4 SLOTS

7.00
177.8mm

4.00
101.6mm

.44
11.2mm

2.00
50.8mm

Figure F

Figure J

.91
23.1mm

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E29

Motor Protection
Amp-Trap® DIN-Style Fuses
R-Rated IEC DIN style MV fuses
Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating
fuses, intended for the short circuit protection of medium voltage motors and motor
controllers. This product range offers North American R-Rated performance in the IEC
282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up
fuses that have a minimum interrupting rating, and must be coordinated with overload
relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered
in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within
this product group are UL component recognized.

Features/Benefits:
•• Clip mount DIN 45: R-Rated fuses with North American ANSI characteristics in a
standard DIN 442mm size.
•• Current-limiting for superior equipment protection
•• Blown fuse indicator provides positive identification of open fuse.
4.5lb tripping force - 1.0” inch.

Highlights:

Applications:

•• R-Rated

•• Short circuit protection of medium

•• UL recognized

voltage motors and motor
controllers.

Definitions:
R-Rating: R-Rated fuses are back-up fuses that operate as follows (Per ANSI
C37.46-2000): An R-Rated fuse will melt in the range of 15 to 35 seconds at a value
of current equal to 100 times the “R” rating.
Back-up Current-Limiting Fuses: A back-up current-limiting fuse is a fuse that can
interrupt any current between its rated minimum interrupting current and its maximum
interrupting current. Back-up fuses are not designed or intended to open under
overload conditions.
Continuous Ampere Rating at 40°C: The continuous amp rating defines the
thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in
fuse selection.

Ratings:
A033D1
Volts	 : 3300V AC
Amps	 : 2 to 19R*
IR	
: 65kA Sym
A055D1
Volts	 : 5300V AC
Amps	 : 2 to 19R*
IR	
: 65kA Sym
A072D1
Volts	 : 7200V AC
Amps	 : 2 to19R*
IR	
: 65kA Sym

Approvals:
•• UL recognized	component File
E93367

Spring-Reinforced Clip
MR45 & Spring Ref.# L096472
Fuse-Holder: SI 24/442 Ref #
K209425
In compliance with IEC 282-1,
DIN standard 43625.
* Note: Ratings above 19R may be
achieved by paralleling fuses. Please
consult factory for details.

E30

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Motor Protection
Amp-Trap® DIN-Style Fuses
Fig.

Catalog Number

Size

Continuous

Continuous

Minimum Interrupting

Amp Rating 550C**

Amp Rating 400C**

Rating RMS Rating

1 Phase Interrupting Rating
Maximum Tested
RMS Asym

RMS Sym

100kA @ 3300V

65kA @ 3300V

100kA @ 5500V

65kA @ 5500V

100kA @ 7200V

65kA @ 7200V

3.3kv Max. DIN IEC Style 442 mm
A

A033D1DSRO-2R

2R

63

70

190

A

A033D1DSRO-3R

3R

90

100

225

A

A033D1DSRO-4R

4R

115

130

225

A

A033D1DSRO-5R

5R

135

150

400

A

A033D1DSRO-6R

6R

150

170

540

A

A033D1DSRO-9R

9R

180

200

780

A

A033D1DSRO-12R

12R

210

230

955

A

A033D1DSRO-13R

13R*

230

260

1050

A

A033D1DSRO-16R

16R*

270

300

1200

A

A033D1DSRO-19R

19R*

280

310

1280

E

5.5kV Max. DIN IEC Style 442 mm
A

A055D1DSRO-2R

2R

63

70

190

A

A055D1DSRO-3R

3R

90

100

225

A

A055D1DSRO-4R

4R

115

130

225

A

A055D1DSRO-5R

5R

135

150

400

A

A055D1DSRO-6R

6R

150

170

540

A

A055D1DSRO-9R

9R

180

200

780

A

A055D1DSRO-12R

12R

210

230

955

A

A055D1DSRO-13R

13R*

230

260

1050

A

A055D1DSRO-16R

16R*

270

300

1200

A

A055D1DSRO-19R

19R*

280

310

1280

190

7.2kV Max. DIN IEC Style 442 mm
A

A072D1DSRO-2R

2R

63

70

A

A072D1DSRO-3R

3R

90

100

225

A

A072D1DSRO-4R

4R

115

130

400

A

A072D1DSRO-5R

5R

135

150

540

A

A072D1DSRO-6R

6R

150

170

550

A

A072D1DSRO-9R

9R

180

200

780

A

A072D1DSRO-12R

12R

210

230

955

A

A072D1DSRO-13R

13R*

230

260

1050

A

A072D1DSRO-16R

16R*

270

300

1200

A

A072D1DSRO-19R

19R*

280

310

1280

* 13R, 16R and 19R are not standard ratings defined in ANSI C37.46.
** This rating defines the thermal capability of the fuse per ANSI 37.46 and should not be the sole factor in fuse selection.

Figure A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E31

Potential Transformer

Amp-Trap® and 9F60 Series PT Fuses
0.625kV – 2.4kV – 2.75kV – 4.8kV – 5.0kV – 5.5kV – 7.2kV –
8.25kV and 15.5kV ferrule mounted fuses:
Mersen PT fuses are current-limiting fuses with high interrupting rating, used for the
primary winding protection of potential transformer. They are small dimension ferrule
type fuses and mount in standard clips. Current ratings are from 0.25A to 5A.

Features/Benefits:
•• Ferrule mounting for standard clips and interchangeability with other brands
of fuses.
•• Current-limiting for superior equipment protection.
•• Non-venting for silent operation.
•• Metal embossed catalog number and manufacturing date for lasting identification.
•• Blown-fuse indicator to give positive identification of open fuse fuse is available on
the 9F60 series.

Applications:
•• Primary protection for potential transformers (PT) or control power
transformers (CPT).

Length
Clip Centers

Diameter

Ferrule
Length

E32

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Ratings:

Amp-Trap
A240T
Volts	 : 2.4kV AC
Amps	 : 0.05 to 5A
IR	
: 50kA Sym
A480T
Volts	 : 4.8kV AC
Amps	 : 0.05 to 5A
: 50kA Sym
IR	
A500T
Volts	 : 5.05kV AC
Amps	 : 0.25 to 5A
IR	
: 50kA Sym
A720T
Volts	 : 7.2kV AC
Amps	 : 0.5 to 3A
IR	
: 50kA Sym
9F60 Series EJ-1
9F60A
Volts	 : .625kV AC
Amps	 : 3 to 5A
IR	
: 100kA Sym
9F60B
Volts	 : 2.75kV AC
	
: 5.5kV AC
	
: 8.25kV AC
	
: 15.5kV AC
Amps	 : 0.5 to 3A
: 60kA Sym
IR	
	
: 80kA Sym
	
: 120kA Sym

www.barr-thorp.com

Potential Transformer

Amp-Trap® and 9F60 Series PT Fuses
0.625kV / 2.4kV / 2.75kV Ferrule mounted fuses:
0.625kV Potential Transformer fuses – 9F60 Series, EJ-1
4.25” (108 mm) Clip Centers
Catalog No.

Amp Rating

9F60AAA003

3A

9F60AAA005

5A

Indicating

Yes

Diameter

Length

Inches (mm)

Inches (mm)

0.812 (20.6)

4.625 (117.5)

Ferrule
Length
Inches (mm)
1.12 (28.4)

Max

Max IR RMS

Spare Parts

Spare Parts

Fuse Support

Voltage

Sym

(Clips*)

(Live Parts)

Indoor (EK-1)

.625 kV

100kA

C08917P

–

–

Max

Max IR RMS

Spare Parts

Spare Parts

Fuse Support

Voltage

Sym

(Clips*)

(Live Parts)

Indoor (EK-1)

2.4kV

50kA

C08917P

–

–

Max

Max IR RMS

Spare Parts

Spare Parts

Fuse Support

Voltage

Sym

(Clips*)

(Live Parts)

Indoor (EK-1)

2.75kV

60kA

C08917P

–

–

Max

Max IR RMS

Spare Parts

Spare Parts

Fuse Support

Voltage

Sym

(Clips*)

(Live Parts)

Indoor (EK-1)

2.75kV

60kA

9F61BWW460

9F61BNW450

–

Max

Max IR RMS

Spare Parts

Spare Parts

Fuse Support

Voltage

Sym

(Clips*)

(Live Parts)

Indoor (EK-1)

2.75 kV

60kA

9F61BWW460

9F61BNW450

9F61ABB101

Catalog No.

Amp Rating

A240T1/2E

0.5A

A240T1E

1A

A240T2E

2A

A240T5E

5A

Indicating

No

Diameter

Length

Inches (mm)

Inches (mm)

0.812 (20.6)

4.625 (117.5)

Ferrule
Length
Inches (mm)

0.625 (15.9)

E

2.4kV Potential Transformer fuses – Amp-Trap Series
4.00” (102 mm) Clip Centers

2.75kV Potential Transformer fuses – 9F60 Series, EJ-1
4.25” (108 mm) Clip Centers
Catalog No.

Amp Rating

9F60AAB001

1A

9F60AAB002

2A

Indicating

Yes

Diameter

Length

Inches (mm)

Inches (mm)

0.812 (20.6)

4.625 (117.5)

Ferrule
Length
Inches (mm)
1.12 (28.4)

2.75kV Potential Transformer fuses – 9F60 Series, EJ-1
6” (152 mm) Clip Centers
Catalog No.

Amp Rating

9F60BBB001

1A

9F60BBB002

2A

9F60BBB003

3A

Indicating

Yes

Diameter

Length

Inches (mm)

Inches (mm)

1.625 (41.3)

7.375 (187)

Ferrule
Length
Inches (mm)

1.31 (33.3)

2.75kV Potential Transformer fuses – 9F60 Series, EJ-1
8.12” (206 mm) Clip Centers
Catalog No.

Amp Rating

9F60BDB001

1A

9F60BDB002

2A

9F60BDB003

3A

Indicating

Yes

Diameter

Length

Inches (mm)

Inches (mm)

1.625 (41.3)

9.5 (241)

Ferrule
Length
Inches (mm)

1.31 (33.3)

*Use two clips per fuse

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E33

Potential Transformer

Amp-Trap® and 9F60 Series PT Fuses
4.8kV / 5kV / 5.4kV Ferrule Mounted Fuses:
4.8kV Potential Transformer fuses – Amp-Trap Series
5“ (127 mm) Clip Centers
Catalog No.

Amp Rating

A480T1/2E

0.5A

A480T3/4E

0.75A

A480T1E

1A

A480T2E

2A

A480T3E

3A

A480T4E

4A

A480T5E

5A

Indicating

No

Diameter

Length

Inches (mm)

Inches (mm)

0.812 (20.6)

5.625 (143)

Ferrule
Length
Inches (mm)

0.625 (15.9)

Max

Max IR RMS

Spare Parts

Spare Parts

Fuse Support

Voltage

Sym

(Clips*)

(Live Parts)

Indoor (EK-1)

4.8kV

50kA

C08917P

–

–

Max

Max IR RMS

Spare Parts

Spare Parts

Fuse Support

Voltage

Sym

(Clips*)

(Live Parts)

Indoor (EK-1)

5.0kV

50kA

–

–

–

Max

Max IR RMS

Spare Parts

Spare Parts

Fuse Support

Voltage

Sym

(Clips*)

(Live Parts)

Indoor (EK-1)

5kV Potential Transformer fuses – Amp-Trap Series
5” (127 mm) Clip Centers
Catalog No.

Amp Rating

A500T1/4E-1

0.25A

A500T1/2E-1

0.5A

A500T1E-1

1A

A500T2E-1

2A

A500T3E-1

3A

A500T4E-1

4A

A500T5E-1

5A

Indicating

No

Diameter

Length

Inches (mm)

Inches (mm)

1.00 (25.4)

5.625 (143)

Ferrule
Length
Inches (mm)

0.563 (14.3)

5.5kV Potential Transformer fuses – 9F60 Series, EJ-1
6.00” (152 mm) Clip Centers
Catalog No.

Amp Rating

9F60BBD905

0.5A

9F60BBD001

1A

9F60BBD002

2A

9F60BBD003

3A

9F60BBN905

0.5A

9F60BBN001

1A

9F60BBN002

2A

9F60BBN003

3A

Ferrule

Diameter

Length

Inches (mm)

Inches (mm)

Yes

1.625 (41.3)

7.375 (187)

1.31 (33.3)

5.5 kV

80kA

9F61BWW460

9F61BNW450

–

No

1.625 (41.3)

7.375 (187)

1.31 (33.3)

5.5 kV

80kA

9F61BWW460

9F61BNW450

–

Max

Max IR RMS

Spare Parts

Spare Parts

Fuse Support

Voltage

Sym

(Clips*)

(Live Parts)

Indoor (EK-1)

5.5 kV

80kA

9F61BWW460

9F61BNW450

9F61ABB101

Indicating

Length
Inches (mm)

5.5kV Potential Transformer fuses – 9F60 Series, EJ-1
8.12” (206 mm) Clip Centers
Catalog No.

Amp Rating

9F60BDD905

0.5A

9F60BDD001

1A

9F60BDD002

2A

9F60BDD003

3A

Indicating

Yes

Diameter

Length

Inches (mm)

Inches (mm)

1.625 (41.3)

9.5 (241)

Ferrule
Length
Inches (mm)

1.31 (33.3)

*Use two clips per fuse

E34

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Potential Transformer

Amp-Trap® and 9F60 Series PT Fuses
7.2kV / 8.25kV / 15.5kV Ferrule mounted fuses:
7.2kV Potential Transformer fuses – Amp-Trap Series
8.88“ (227 mm) Clip Centers
Catalog No.

Amp
Rating

A720T1/2E-1

0.5A

A720T3/4-1

0.75A

A720T1E-1

1A

A720T2E-1

2A

A720T3E-1

3A

Indicating

No

Diameter

Length

Ferrule Length

Max

Max IR RMS

Spare Parts

Spare Parts

Fuse Support

Inches (mm)

Inches (mm)

Inches (mm)

Voltage

Sym

(Clips*)

(Live Parts)

Indoor (EK-1)

0.812 (20.6)

9.5 (241)

0.625 (15.9)

7.2kV

50kA

C08917P

–

–

Catalog No.

Amp
Rating

9F60BDE905

0.5A

9F60BDE001

1A

9F60BDE002

2A

9F60BDE003

3A

Indicating

Yes

E

8.25kV Potential Transformer fuses – 9F60 Series, EJ-1
8.12” (206 mm) Clip Centers
Diameter

Length

Ferrule Length

Max

Max IR RMS

Spare Parts

Spare Parts

Fuse Support

Inches (mm)

Inches (mm)

Inches (mm)

Voltage

Sym

(Clips*)

(Live Parts)

Indoor (EK-1)

1.625 (41.3)

9.5 (241)

1.31 (33.3)

8.25 kV

80kA

9F61BWW460

9F61BNW450

9F61ABG101

15.5kV Potential Transformer fuses – 9F60 Series, EJ-1
11.5” (292 mm) Clip Centers
Catalog No.

Amp
Rating

Indicating

Diameter

Length

Ferrule Length

Max

Max IR RMS

Spare Parts

Spare Parts

Fuse Support

Inches (mm)

Inches (mm)

Inches (mm)

Voltage

Sym

(Clips*)

(Live Parts)

Indoor (EK-1)

9F60BHH905

0.5A

9F61ADG101

9F60BHH001

1A

(13.8kV nominal - 95

9F60BHH002

2A

9F60BHH003

3A

Yes

1.625 (41.3)

12.875 (327)

1.31 (33.3)

15.5 kV

120kA

9F61BWW460

9F61BNW450

kV BIL)
9F61ADJ101
(14.4kV nominal - 110kV
BIL)

*Use two clips per fuse

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E35

Capacitor Protection
Amp-Trap® and 9F60 Series
Medium voltage capacitor fuses:
Mersen capacitor fuses are designed to ANSI C37-41. They are current-limiting
operating without noise or discharge and are designed to be used indoors in a
general purpose enclosure or outdoors in a weatherproof enclosure. These are nondisconnecting fuses requiring the use of a disconnect switch. These capacitor fuses
provide both short circuit and overload protection and are intended to protect against
capacitor case rupture or dielectric failure within the capacitor.
The various mounting configurations offer manufacturers a wide range of cost and
space saving solutions and a large choice of equivalent products to users.

Features/Benefits:

Applications:

•• High interrupting capacity

•• Capacitor Protection

•• Current limitation		

•• Power Factor Correction

•• Blown-fuse indication

Equipment

•• Direct mount

•• Harmonic Filtering Equipment

•• Clip style mount	

•• Induction Heating System

•• Bus mount

•• High Power Drive

•• Non-venting for silent operation

•• Welders

Catalog Numbering System:

A 250 C 125 - 30
Voltage Rating ÷ 10
AC Voltage

(250 = 2.5kV)

Current Rating

Capacitor Fuse

Mounting Configuration

Ratings:
A100C
Volts	
Amps	
IR	
A150C
Volts	
Amps	
IR	
A250C
Volts	
Amps	
IR	
A300C
Volts	
Amps	
IR	
A430C
Volts	
Amps	
IR	
A550C
Volts	

: 1000V AC Max.
: 25 to 125 A
: 50 kA Sym
: 1500V AC Max.
: 25 to 200 A
: 40 kA Sym
: 2500V AC Max.
: 25 to 200 A
: 50 kA Sym

: 3000V AC Max.
: 50 to 175 A
: 50 kA Sym
: 4300V AC Max.
: 6 to 100 A
: 65 kA Sym
: 5500V AC Max.

Amps	 : 6 to 75 A
IR	
: 65 kA Sym
9F60RJD
Volts	 : 5500V AC Max.
Amps	 : 25 to 80 A
IR	
: 50 kA Sym
9F60RJF
Volts	 : 9520V AC Max.
Amps	 : 15 to 40A
IR	
: 50 kA Sym

E36

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Capacitor Protection
Amp-Trap® and 9F60 Series

1.0 kV - 1.5 kV Capacitor Fuses Amp-Trap Series
Ampere

Melting

Number

Rating

I2t (kA2s)

Maximum 1

Maximum 1

Clearing

Phase Interrupting

I2t (kA s)

Rating

2

1.5 kV Max Type 10 inner thread to screw
A150C25-10

25

4

12

A150C50-10

50

16

50

A150C60-10

60

25

70

A150C75-10

75

35

110

A150C90-10

90

50

150

A150C100-10

100

65

200

A150C110-10

110

80

250

A150C120-10

120

100

310

A150C125-10

125

125

330

A150C130-10

130

125

330

A150C135-10

135

130

350

A150C140-10

140

130

350

A150C150-10

150

150

390

A150C160-10

160

185

480

A150C165-10

165

185

480

A150C175-10

175

225

600

A150C200-10

200

300

800

40 kA @1500V
RMS Sym

Overall Length

Tube Length

Ind. Housing

Body Dia

Bracket Dimensions

Inches (mm)

Inches (mm)

Inches (mm)

Inches (mm)

Inches (mm)

A

B

C

D

E

F

7.08 (179.8)

6.38 (162.1)

.70 (17.8)

1.42 (36.0)

6.84 (173.6)

5.73 (145.5)

1.42 (36.0)

1.10 (27.9)

3.00 (76.2)

1.25 (31.8)

7.48 (189.9)

6.37 (161.8)

.75 (19.1)

1.42 (36.0)

3.00 (76.2)

1.25 (31.8)

E

Catalog

1.5 kV Max Type 20 screw to bolt (flat bracket)
A150C25-20

25

3.2

6.5

A150C50-20

50

13

27

A150C60-20

60

18

38

A150C75-20

75

30

60

A150C90-20

90

35

72

A150C100-20

100

52

105

A150C110-20

110

58

120

A150C120-20

120

73

150

A150C125-20

125

82

165

A150C130-20

130

90

190

A150C135-20

135

90

190

A150C140-20

140

105

220

A150C150-20

150

120

240

A150C160-20

160

185

480

A150C165-20

165

185

480

A150C175-20

175

225

600

A150C200-20

200

300

800

40 kA @1500V
RMS Sym

Type 10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Type 20

www.barr-thorp.com

E37

Capacitor Protection
Amp-Trap® and 9F60 Series

1.0 kV - 1.5 kV Capacitor Fuses Amp-Trap Series
Catalog

Ampere

Melting

Number

Rating

I t (kA s)
2

2

Maximum 1

Maximum 1

Clearing

Phase Interrupting

I2t (kA2s)

Rating

1.0 kV Max Type 30 external female to bolt (L bracket)
A100C25-30

25

4

10

A100C50-30

50

16

40

A100C60-30

60

25

60

A100C75-30

75

35

95

50 kA @1000V

A100C90-30

90

50

130

RMS Sym

A100C100-30

100

65

165

A100C110-30

110

80

205

A100C125-30

125

100

250

Overall Length

Tube Length

Ind. Housing

Body Dia

Bracket Dimensions

Inches (mm)

Inches (mm)

Inches (mm)

Inches (mm)

Inches (mm)

A

B

C

D

E

F

6.38 (162.1)

4.42 (112.3)

75 (19.1)

1.10 (27.9)

5.76 (146.2)

1.25 (31.8)

6.84 (173.6)

4.78 (121.4)

.51 (13.0)

1.75 (27.9)

.75 (19.1)

1.41 (35.8)

8.11 (206.0)

5.74 (145.8)

.75 (19.1)

1.10 (27.9)

7.49 (190.2)

1.25 (31.8)

8.71 (221.1)

6.51 (165.2)

.70 (17.8)

1.42 (36.0)

8.08 (205.2)

1.5 kV Max Type 40 external female to external female
A150C100-40

100

125

140

A150C110-40

110

125

180

A150C125-40

125

130

230

A150C130-40

130

130

230

40 kA @1500V

A150C140-40

140

150

285

RMS Sym

A150C150-40

150

185

315

A150C160-40

160

185

360

A150C175-40

175

225

410

A150C200-40

200

300

560

1.5 kV Max Type 50 screw to bolt (L bracket)
A150C50-50

50

13

27

A150C60-50

60

18

38

A150C75-50

75

30

60

A150C90-50

90

35

72

A150C100-50

100

52

105

A150C110-50

110

58

120

40 kA @1500V

A150C120-50

120

73

150

RMS Sym

A150C125-50

125

82

165

A150C130-50

130

90

190

A150C135-50

135

90

190

A150C140-50

140

105

220

A150C150-50

150

120

240

A150C160-50

160

185

480

A150C165-50

165

185

480

A150C175-50

175

225

600

A150C200-50

200

300

800

Type 30

E38

Type 40

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Type 50

www.barr-thorp.com

Capacitor Protection
Amp-Trap® and 9F60 Series

2.5 kV Capacitor Fuses Amp-Trap Series
Catalog

Ampere

Melting

Number

Rating

I t (kA s)
2

2

Maximum 1

Maximum 1

Clearing

Phase Interrupting

I2t (kA2s)

Rating

2.5 kV Max Type 10 inner thread to screw
25

3

9

A250C50-10

50

12

35

A250C65-10

65

18

60

A250C75-10

75

25

85

A250C80-10

80

25

85

50 kA @2500V

A250C100-10

100

45

150

RMS Sym

A250C110-10

110

60

190

A250C125-10

125

75

240

A250C135-10

135

115

395

A250C150-10

150

130

460

A200C165-10

165

150

350

A200C175-10

175

165

440

A200C200-10

200

225

500

Tube Length

Ind. Housing

Body Dia

Bracket Dimensions

Inches (mm)

Inches (mm)

Inches (mm)

Inches (mm)

Inches (mm)

A

B

C

D

E

F

7.67 (194.8)

6.92 (175.8)

.75 (19.1)

7.67 (194.8)

6.92 (175.8)

.75 (19.1)

1.42 (36.0)

9.41 (239.0)

6.66 (169.2)

.75 (19.1)

1.10 (27.9)

8.79 (223.2)

1.25 (31.8)

9.11 (231.4)

6.74 (171.2)

.75 (19.1)

1.10 (27.9)

8.49 (215.6)

1.25 (31.8)

9.29 (236.0)

6.92 (175.8)

.75 (19.1)

1.42 (36.0)

8.67 (220.2)

1.25 (31.8)

1.42 (36.0)

E

A250C25-10

Overall Length

40 kA @2000V
RMS Sym

2.5 kV Max Type 30 external female to bolt (L bracket)
A250C25-30

25

3

9

A250C50-30

50

12

35

A250C65-30

65

18

60

A250C75-30

75

25

85

A250C80-30

80

25

85

A250C100-30

100

45

150

A250C110-30

110

60

190

A250C125-30

125

75

240

50 kA @2500V
RMS Sym

2.5 kV Max Type 50 screw to bolt (L bracket)
A250C25-50

25

3

9

A250C50-50

50

12

35

A250C65-50

65

18

60

A250C75-50

75

25

85

A250C80-50

80

25

85

50 kA @2500V
RMS Sym

A250C100-50

100

45

150

A250C110-50

110

60

190

A250C125-50

125

75

240

A250C135-50

135

115

395

A250C150-50

150

130

460

A200C165-50

165

150

350

A200C175-50

175

165

440

A200C200-50

200

225

500

Type 10

40 kA @2000V
RMS Sym

Type 30

Type 50

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E39

Capacitor Protection
Amp-Trap® and 9F60 Series

3.0 kV Capacitor Fuses Amp-Trap Series
Catalog

Ampere

Melting

Number

Rating

I2t (kA2s)

Maximum 1

Maximum 1

Clearing

Phase Interrupting

I2t (kA2s)

Rating

3.0 kV Max Type 10 inner thread to screw
A300C50-10

60

12

35

A300C60-10

75

18

65

A300C75-10

95

26

80

A300C95-10

100

45

140

A300C100-10

115

45

140

50 kA @3000V

A300C115-10

125

60

200

RMS Sym

A300C125-10

130

75

260

A300C130-10

150

75

260

A300C150-10

175

105

350

165

530

A300C175-10

Overall Length

Tube Length

Ind. Housing

Body Dia

Bracket Dimensions

Inches (mm)

Inches (mm)

Inches (mm)

Inches (mm)

Inches (mm)

A

B

C

D

E

F

10.16 (258.1)

9.33 (237.0)

.75 (19.1)

1.10 (27.9)

10.16 (258.1)

9.33 (237.0)

.75 (19.1)

1.42 (36.0)

10.59 (269.1)

9.33 (237.0)

.75 (19.1)

1.10 (27.9)

3.00 (76.2)

1.25 (31.8)

10.59 (269.0)

9.33 (237.0)

.75 (19.1)

1.42 (36.0)

3.00 (76.2)

1.25 (31.8)

13.27 (337.1)

9.41 (239.0)

.47 (11.9)

1.42 (36.0)

12.02 (305.2) 1.25 (31.8)

3.0 kV Max Type 20 screw to bolt (flat bracket)
A300C50-20

60

12

35

A300C60-20

75

18

65

A300C75-20

95

26

80

A300C95-20

100

45

140

A300C100-20

115

45

140

50 kA @3000V

A300C115-20

125

60

200

RMS Sym

A300C125-20

130

75

260

A300C130-20

150

75

260

A300C150-20

175

105

350

165

530

A300C175-20

3.0 kV Max Type 60 bolt (L bracket) to bolt (L bracket)
A300C50-60

60

12

35

A300C60-60

75

18

65

A300C75-60

95

26

80

A300C95-60

100

45

140

A300C100-60

115

45

140

50 kA @3000V

A300C115-60

125

60

200

RMS Sym

A300C125-60

130

75

260

A300C130-60

150

75

260

A300C150-60

175

105

350

165

530

A300C175-60

Type 10
Type 20

E40

Type 60
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Capacitor Protection
Amp-Trap® and 9F60 Series

4.3 kV Capacitor Fuses Amp-Trap Series
Catalog

Ampere

Melting

Maximum 1

Maximum 1

Overall Length Tube Length

Ind. Housing

Body Dia

Bracket Dimensions

Number

Rating

I2t (kA2s)

Clearing I2t (kA2s)

Phase Interrupting Rating

Inches (mm)

Inches (mm)

Inches (mm)

Inches (mm)

Inches (mm)

A

B

C

D

E

F

9.50 (241.3)

7.12 (180.8)

.75 (19.1)

2.00 (50.8)

8.00 (203.2)

.75 (19.1)

10.00 (254.0)

7.12 (180.8)

1.00 (25.4)

2.00 (50.8)

8.00 (203.2)

.63 (15.9)

9.75 (247.7)

7.12 (180.8)

1.00 (2.54)

2.00 (50.8)

8.00 (203.2)

0.63 (15.9)

4.3 kV Max Type 15 external female to bolt
A430C6-15

6

0.4

2.49

A430C8-15

8

0.73

4.31

A430C10-15

10

1.14

6.38

A430C12-15

12

1.6

8.64

A430C18-15

18

3

15

A430C20-15

20

4.5

22.1

A430C25-15

25

6.5

31.2

30

7.7

36.2

65 kA @4300V

35

9

41.4

RMS Sym

A430C45-15

45

12

54.6

A430C50-15

50

15

68

A430C65-15

65

29

84

A430C75-15

75

36

100

A430C80-15

80

42

120

A430C90-15

90

58

160

A430C100-15

100

66

180

E

A430C30-15
A430C35-15

4.3 kV Max Type 70 tube to tube
A430C6-70

6

0.4

A430C8-70

8

0.73

2.49
4.31

A430C10-70

10

1.14

6.38

A430C12-70

12

1.6

8.64

A430C18-70

18

3

15

A430C20-70

20

4.5

22.1

A430C25-70

25

6.5

31.2

A430C30-70

30

7.7

36.2

A430C35-70

35

9

41.4

A430C45-70

45

12

54.6

A430C50-70

50

15

68

A430C65-70

65

29

84

A430C75-70

75

36

100

A430C80-70

80

42

120

A430C90-70

90

58

160

A430C100-70

100

66

180

65 kA @4300V
RMS Sym

4.35 kV Max Type 75 external female to tube
A430C6-75

6

0.4

A430C8-75

8

0.73

2.49
4.31

A430C10-75

10

1.14

6.38

A430C12-75

12

1.6

8.64

A430C18-75

18

3

15

A430C20-75

20

4.5

22.1

A430C25-75

25

6.5

31.2

A430C30-75

30

7.7

36.2

65 kA @ 4300V

A430C35-75

35

9

41.4

RMS Sym

A430C45-75

45

12

54.6

A430C50-75

50

15

68

A430C65-75

65

29

84

A430C75-75

75

36

100

A430C80-75

80

42

120

A430C90-75

90

58

160

A430C100-75

100

66

180

Type 15

Type 70

Type 75

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E41

Capacitor Protection
Amp-Trap® and 9F60 Series

5.5 kV Capacitor Fuses Amp-Trap Series
Catalog

Ampere

Melting

Number

Rating

I t (kA s)
2

2

Maximum 1

Maximum 1

Clearing

Phase Interrupting

I2t (kA2s)

Rating

5.5 kV Max Type 15 external female to bolt
A550C6-15

6

0.4

2.49

A550C8-15

8

0.73

4.31

A550C10-15

10

1.14

6.38

A550C12-15

12

1.6

8.64

A550C18-15

18

3

15

65 kA @ 5500V

A550C20-15

20

4.5

22.1

RMS Sym

A550C25-15

25

6.5

31.2

A550C30-15

30

7.7

36.2
41.4

A550C35-15

35

9

A550C40-15

40

12

54.6

A550C50-15

50

15

68

A550C65-15

65

35

156

A550C75-15

75

43

186

Overall Length

Tube Length

Ind. Housing

Body Dia

Bracket Dimensions

Inches (mm)

Inches (mm)

Inches (mm)

Inches (mm)

Inches (mm)

A

B

C

D

E

F

9.50 (241.3)

7.12 (180.8)

.75 (19.1)

2.00 (50.8)

8.00 (203.2)

.75 (19.1)

10.00 (254.0)

7.12 (180.8)

1.00 (25.4)

2.00 (50.8)

8.00 (203.2)

.63 (15.9)

50 kA @ 5500V
RMS Sym

5.5 kV Max Type 70 tube to tube
A550C6-70

6

0.4

2.49

A550C8-70

8

0.73

4.31

A550C10-70

10

1.14

6.38

A550C12-70

12

1.6

8.64

A550C18-70

18

3

15

65 kA @ 5500V

A550C20-70

20

4.5

22.1

RMS Sym

A550C25-70

25

6.5

31.2

A550C30-70

30

7.7

36.2
41.4

A550C35-70

35

9

A550C40-70

40

12

54.6

A550C50-70

50

15

68

A550C65-70

65

35

156

A550C75-70

75

43

186

Type 15

E42

50 kA @ 5500V RMS Sym

Type 70

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Capacitor Protection
Amp-Trap® and 9F60 Series

5.5kV / 9.52kV Capacitor Fuses Amp-Trap Series
5.5kV Capacitor Fuses - Amp-Trap Series

Rating

Melting
I2t
(kA2s)

Maximum
Clearing
It
2

(kA2s)

Maximum 1 Phase

Overall

Tube

Indicator

Body Dia

Interrupting

Length

Length

Housing

Inches

Rating (kA)

Inches (mm)

Inches (mm)

Inches (mm)

(mm)

A

B

C

9.75 (247.7)

7.12 (180.8)

1.00 (2.54)

5.5 kV Max Type 75 external female to tube
A550C6-75

6

0.4

2.49

A550C8-75

8

0.73

4.31

A550C10-75

10

1.14

6.38

A550C12-75

12

1.6

8.64

A550C18-75

18

3

15

A550C20-75

20

4.5

22.1

A550C25-75

25

6.5

31.2

A550C30-75

30

7.7

36.2

A550C35-75

35

9

41.4

A550C40-75

40

12

54.6

A550C50-75

50

15

68

A550C65-75

65

35

156

50 kA @ 5500V

A550C75-75

75

43

186

RMS Sym

Inches

Inches

(mm)

(mm)

D

E

F

2.00 (50.8)

8.00 (203.2)

0.63 (15.9)

65 kA @ 5500V
RMS Sym

E

Catalog Number

Ampere

Type 75

5.5kV Capacitor fuses – 9F60 series, EJO-5
12” (305 mm) Clip Centers clip-in mounting* - Suitable for use indoors or outdoors
Catalog No.

Amp

No. of

Rating

Barrels

9F60RJD025

25A

9F60RJD040

40A

9F60RJD080

80A

1

Indicating

Yes

Diameter

Length

Inches (mm)

Inches (mm)

2.08 (20.8)

14.0 (356)

Max Voltage

5.5 kV

Max IR
RMS Sym

50kA

9.52kV Capacitor fuses – 9F60 series, EJO-5
12” (305 mm) Clip Centers clip-in mounting* - Suitable for use indoors or outdoors
Catalog No.

Amp

No. of

Rating

Barrels

9F60RJF015

15A

9F60RJF025

25A

9F60RJF040

40A

1

Indicating

Yes

Diameter

Length

Inches (mm)

Inches (mm)

2.08 (20.8)

14.0 (356)

Max Voltage

9.25 kV

Max IR
RMS Sym

50kA

*EJO-5 Capacitor fuses are typically mounted directly on the capacitor.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E43

Distribution Transformer Protection
Sure Guard 9F59U Series ETP Fuses
8.3kV / 15.5kV / 23.0kV ETP fuses
The Sure Guard ETP back-up current-limiting fuses are designed to protect
distribution transformers and are used in series with another protective device (such
as an expulsion fuse). This combination limits the high-fault current to a safe level,
thus providing protection through the complete range. As its name implies, the “ETP”
is for External Transformer Protection. For conventional transformers protected by
expulsion-fuses cutouts, the ETP can be installed in series with the cutout. For self
protected transformers, the ETP can be applied on the high-voltage bushing in series
with the internal transformer expulsion fuse.

Features/Benefits:
•• Various hardware options.
•• Current-limiting for superior equipment protection.
•• High fault current interrupting capability: I.R. Sym = 50kA at ETP voltage rating.

Highlights:

Applications:

Ratings:

•• Outdoor use

•• Overhead distribution systems

9F50UBC:
Volts	

Definitions:

: 8.3kV AC

9F50UBD:
Volts	

Back-up Current-Limiting Fuses:
A back-up current-limiting fuse is a fuse that can interrupt any current between its rated
minimum interrupting current and its maximum interrupting current. Back-up fuses are

: 15.5kV AC

9F50UBE:
Volts	

: 23.0kV AC

not designed or intended to open under overload conditions.

Hardware Options:

Catalog No. Suitable
for Parallel Application

Fig. 2. Eyebolt only,
for 6-2/0 cable
9F59AAW008

Fig. 1. Adapter only
9F59AAW007

Fig. 3. Parallel groove only,
for 2/0 to 250MCM cable
9F59AAW009

E44

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Catalog Number

Max kV

9F59UBC208

8.3

9F59UBC218

8.3

9F59UBC228

8.3

9F59UBC238

8.3

9F59UBC248

8.3

9F59UBC258

8.3

9F59UBC268

8.3

9F59UBC278

8.3

9F59UBC288

8.3

9F59UBD208

15.5

9F59UBD218

15.5

9F59UBD228

15.5

9F59UBD238

15.5

9F59UBD248

15.5

9F59UBD258

15.5

9F59UBD268

15.5

9F59UBD278

15.5

9F59UBD288

15.5

www.barr-thorp.com

Distribution Transformer Protection
Sure Guard 9F59U Series ETP Fuses
Sure Guard rated 8.3kV
Let-

Minimum

Recommended

Max. Total I.C.

kV Class

Max. Expulsion

I2t

Amperes Curve

Clear Curve

Without Hardware

15

8T or 12K

16000

440

GES-8228A

GES-8229A

GET-6693A

(1) Adapter

15

8T or 12K

16000

440

GES-8228A

GES-8229A

GET-6693A

(1) Eyebolt Terminal

15

8T or 12K

16000

440

GES-8228A

GES-8229A

GET-6693A

(1) Parallel Groove

15

8T or 12K

16000

440

GES-8228A

GES-8229A

GET-6693A

Without Hardware

15

8T or 12K

16000

440

GES-8228A

GES-8229A

GET-6693A

(1) Adapter

15

8T or 12K

16000

440

GES-8228A

GES-8229A

GET-6693A

8.3, Spade & Spade

(1) Eyebolt Terminal

15

8T or 12K

16000

440

GES-8228A

GES-8229A

GET-6693A

9F59UBC231

8.3, Spade & Spade

(1) Parallel Groove

15

8T or 12K

16000

440

GES-8228A

GES-8229A

GET-6693A

9F59UBC241

8.3, Spade & Spade

Adapter & eyebolt terminal

15

8T or 12K

16000

440

GES-8228A

GES-8229A

GET-6693A
GET-6693A

ETP Rating

ETP Hardware

9F59UBC101

8.3, Spade & Stud

9F59UBC111

8.3, Spade & Stud

9F59UBC121

8.3, Spade & Stud

9F59UBC131

8.3, Spade & Stud

9F59UBC201

8.3, Spade & Spade

9F59UBC211

8.3, Spade & Spade

9F59UBC221

Min. Melt

Total

through
Curve

9F59UBC251

8.3, Spade & Spade

Adapter & parallel groove

15

8T or 12K

16000

440

GES-8228A

GES-8229A

9F59UBC261

8.3, Spade & Spade

Eyebolt terminal & parallel groove

15

8T or 12K

16000

440

GES-8228A

GES-8229A

GET-6693A

9F59UBC271

8.3, Spade & Spade

(2) Eyebolt terminals

15

8T or 12K

16000

440

GES-8228A

GES-8229A

GET-6693A

9F59UBC281

8.3, Spade & Spade

(2) Parallel groove

15

8T or 12K

16000

440

GES-8228A

GES-8229A

GET-6693A

9F59UBC102

8.3, Spade & Stud

Without Hardware

15

15T or 25K

50000

450

GES-8228A

GES-8229A

GET-6693A

9F59UBC112

8.3, Spade & Stud

(1) Adapter

15

15T or 25K

50000

450

GES-8228A

GES-8229A

GET-6693A

9F59UBC122

8.3, Spade & Stud

(1) Eyebolt Terminal

15

15T or 25K

50000

450

GES-8228A

GES-8229A

GET-6693A

9F59UBC132

8.3, Spade & Stud

(1) Parallel Groove

15

15T or 25K

50000

450

GES-8228A

GES-8229A

GET-6693A

9F59UBC202

8.3, Spade & Spade

Without Hardware

15

15T or 25K

50000

450

GES-8228A

GES-8229A

GET-6693A

9F59UBC212

8.3, Spade & Spade

(1) Adapter

15

15T or 25K

50000

450

GES-8228A

GES-8229A

GET-6693A

9F59UBC222

8.3, Spade & Spade

(1) Eyebolt Terminal

15

15T or 25K

50000

450

GES-8228A

GES-8229A

GET-6693A
GET-6693A

9F59UBC232

8.3, Spade & Spade

(1) Parallel Groove

15

15T or 25K

50000

450

GES-8228A

GES-8229A

9F59UBC242

8.3, Spade & Spade

Adapter & eyebolt terminal

15

15T or 25K

50000

450

GES-8228A

GES-8229A

GET-6693A

9F59UBC252

8.3, Spade & Spade

Adapter & parallel groove

15

15T or 25K

50000

450

GES-8228A

GES-8229A

GET-6693A

9F59UBC262

8.3, Spade & Spade

Eyebolt terminal & parallel groove

15

15T or 25K

50000

450

GES-8228A

GES-8229A

GET-6693A

9F59UBC272

8.3, Spade & Spade

(2) Eyebolt terminals

15

15T or 25K

50000

450

GES-8228A

GES-8229A

GET-6693A
GET-6693A

9F59UBC282

8.3, Spade & Spade

(2) Parallel groove

15

15T or 25K

50000

450

GES-8228A

GES-8229A

9F59UBC104

8.3, Spade & Stud

Without Hardware

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC114

8.3, Spade & Stud

(1) Adapter

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC124

8.3, Spade & Stud

(1) Eyebolt Terminal

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC134

8.3, Spade & Stud

(1) Parallel Groove

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC204

8.3, Spade & Spade

Without Hardware

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC214

8.3, Spade & Spade

(1) Adapter

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC224

8.3, Spade & Spade

(1) Eyebolt Terminal

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC234

8.3, Spade & Spade

(1) Parallel Groove

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC244

8.3, Spade & Spade

Adapter & eyebolt terminal

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC254

8.3, Spade & Spade

Adapter & parallel groove

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC264

8.3, Spade & Spade

Eyebolt terminal & parallel groove

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC274

8.3, Spade & Spade

(2) Eyebolt terminals

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC284

8.3, Spade & Spade

(2) Parallel groove

15

25T or 40K

140000

560

GES-8228A

GES-8229A

GET-6693A

9F59UBC208

8.3, Spade & Spade

Without Hardware

15

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBC218

8.3, Spade & Spade

(1) Adapter

15

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBC228

8.3, Spade & Spade

(1) Eyebolt Terminal

15

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBC238

8.3, Spade & Spade

(1) Parallel Groove

15

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBC248

8.3, Spade & Spade

Adapter & eyebolt terminal

15

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBC258

8.3, Spade & Spade

Adapter & parallel groove

15

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBC268

8.3, Spade & Spade

Eyebolt terminal & parallel groove

15

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBC278

8.3, Spade & Spade

(2) Eyebolt terminals

15

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBC288

8.3, Spade & Spade

(2) Parallel groove

15

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E

Catalog No.

E45

Distribution Transformer Protection
Sure Guard 9F59U Series ETP Fuses
Sure Guard rated 15.5kV

E46

Min kV

Recommended

Max. Total

I.C.

Min. Melt

Total

Let-through

Class

Max. Expulsion

I2t

Amperes

Curve

Clear Curve

Curve

Without Hardware

25

8T or 12K

16000

510

GES-8228A

GES-8229A

GET-6693A

(1) Adapter

25

8T or 12K

16000

510

GES-8228A

GES-8229A

GET-6693A

Catalog No.

ETP Rating

ETP Hardware

9F59UBD101

15.5, Spade & Stud

9F59UBD111

15.5, Spade & Stud

9F59UBD121

15.5, Spade & Stud

(1) Eyebolt Terminal

25

8T or 12K

16000

510

GES-8228A

GES-8229A

GET-6693A

9F59UBD131

15.5, Spade & Stud

(1) Parallel Groove

25

8T or 12K

16000

510

GES-8228A

GES-8229A

GET-6693A

9F59UBD201

15.5, Spade & Spade

Without Hardware

25

8T or 12K

16000

510

GES-8228A

GES-8229A

GET-6693A

9F59UBD211

15.5, Spade & Spade

(1) Adapter

25

8T or 12K

16000

510

GES-8228A

GES-8229A

GET-6693A

9F59UBD221

15.5, Spade & Spade

(1) Eyebolt Terminal

25

8T or 12K

16000

510

GES-8228A

GES-8229A

GET-6693A

9F59UBD231

15.5, Spade & Spade

(1) Parallel Groove

25

8T or 12K

16000

510

GES-8228A

GES-8229A

GET-6693A

9F59UBD241

15.5, Spade & Spade

Adapter & eyebolt terminal

25

8T or 12K

16000

510

GES-8228A

GES-8229A

GET-6693A

9F59UBD251

15.5, Spade & Spade

Adapter & parallel groove

25

8T or 12K

16000

510

GES-8228A

GES-8229A

GET-6693A

9F59UBD261

15.5, Spade & Spade

Eyebolt terminal & parallel groove

25

8T or 12K

16000

510

GES-8228A

GES-8229A

GET-6693A

9F59UBD271

15.5, Spade & Spade

(2) Eyebolt terminals

25

8T or 12K

16000

510

GES-8228A

GES-8229A

GET-6693A

9F59UBD102

15.5, Spade & Stud

Without Hardware

25

15T or 25K

50000

480

GES-8228A

GES-8229A

GET-6693A

9F59UBD112

15.5, Spade & Stud

(1) Adapter

25

15T or 25K

50000

480

GES-8228A

GES-8229A

GET-6693A

9F59UBD122

15.5, Spade & Stud

(1) Eyebolt Terminal

25

15T or 25K

50000

480

GES-8228A

GES-8229A

GET-6693A

9F59UBD132

15.5, Spade & Stud

(1) Parallel Groove

25

15T or 25K

50000

480

GES-8228A

GES-8229A

GET-6693A

9F59UBD202

15.5, Spade & Spade

Without Hardware

25

15T or 25K

50000

480

GES-8228A

GES-8229A

GET-6693A

9F59UBD212

15.5, Spade & Spade

(1) Adapter

25

15T or 25K

50000

480

GES-8228A

GES-8229A

GET-6693A

9F59UBD222

15.5, Spade & Spade

(1) Eyebolt Terminal

25

15T or 25K

50000

480

GES-8228A

GES-8229A

GET-6693A

9F59UBD232

15.5, Spade & Spade

(1) Parallel Groove

25

15T or 25K

50000

480

GES-8228A

GES-8229A

GET-6693A

9F59UBD242

15.5, Spade & Spade

Adapter & eyebolt terminal

25

15T or 25K

50000

480

GES-8228A

GES-8229A

GET-6693A
GET-6693A

9F59UBD252

15.5, Spade & Spade

Adapter & parallel groove

25

15T or 25K

50000

480

GES-8228A

GES-8229A

9F59UBD262

15.5, Spade & Spade

Eyebolt terminal & parallel groove

25

15T or 25K

50000

480

GES-8228A

GES-8229A

GET-6693A

9F59UBD272

15.5, Spade & Spade

(2) Eyebolt terminals

25

15T or 25K

50000

480

GES-8228A

GES-8229A

GET-6693A

9F59UBD282

15.5, Spade & Spade

(2) Parallel groove

25

15T or 25K

50000

480

GES-8228A

GES-8229A

GET-6693A

9F59UBD104

15.5, Spade & Stud

Without Hardware

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD114

15.5, Spade & Stud

(1) Adapter

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD124

15.5, Spade& Stud

(1) Eyebolt Terminal

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD134

15.5, Spade & Stud

(1) Parallel Groove

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD204

15.5, Spade & Spade

Without Hardware

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD214

15.5, Spade & Spade

(1) Adapter

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD224

15.5, Spade & Spade

(1) Eyebolt Terminal

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD234

15.5, Spade & Spade

(1) Parallel Groove

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD244

15.5, Spade & Spade

Adapter & eyebolt terminal

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD254

15.5, Spade & Spade

Adapter & parallel groove

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD264

15.5, Spade & Spade

Eyebolt terminal & parallel groove

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD274

15.5, Spade & Spade

(2) Eyebolt terminals

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD284

15.5, Spade & Spade

(2) Parallel groove

25

25T or 40K

140000

890

GES-8228A

GES-8229A

GET-6693A

9F59UBD208

15.5, Spade & Spade

Without Hardware

25

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBD218

15.5, Spade & Spade

(1) Adapter

25

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBD228

15.5, Spade & Spade

(1) Eyebolt Terminal

25

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBD238

15.5, Spade & Spade

(1) Parallel Groove

25

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBD248

15.5, Spade & Spade

Adapter & eyebolt terminal

25

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBD258

15.5, Spade & Spade

Adapter & parallel groove

25

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBD268

15.5, Spade & Spade

Eyebolt terminal & parallel groove

25

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBD278

15.5, Spade & Spade

(2) Eyebolt terminals

25

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

9F59UBD288

15.5, Spade & Spade

(2) Parallel groove

25

50T or 80K

88000

1200

GES-8228A

GES-8229A

GET-6693A

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Distribution Transformer Protection
Sure Guard 9F59U Series ETP Fuses

Catalog No.
9F59UBE101

ETP Rating
23.0, Spade & Stud

kV

Recommended

Max. Total

Minimum

Class

Max. Expulsion

I 2t

I.C. Amperes

Without Hardware

35

8T or 12K

16000

280

ETP Hardware

Total

Let-through

Clear Curve

Curve

GES-8228A

GES-8229A

GET-6693A

Min. Melt Curve

9F59UBE111

23.0, Spade & Stud

(1) Adapter

35

8T or 12K

16000

280

GES-8228A

GES-8229A

GET-6693A

9F59UBE121

23.0, Spade & Stud

(1) Eyebolt Terminal

35

8T or 12K

16000

280

GES-8228A

GES-8229A

GET-6693A

9F59UBE131

23.0, Spade & Stud

(1) Parallel Groove

35

8T or 12K

16000

280

GES-8228A

GES-8229A

GET-6693A

9F59UBE201

23.0, Spade & Spade

Without Hardware

35

8T or 12K

16000

280

GES-8228A

GES-8229A

GET-6693A

9F59UBE211

23.0, Spade & Spade

(1) Adapter

35

8T or 12K

16000

280

GES-8228A

GES-8229A

GET-6693A

9F59UBE221

23.0, Spade & Spade

(1) Eyebolt Terminal

35

8T or 12K

16000

280

GES-8228A

GES-8229A

GET-6693A

9F59UBE231

23.0, Spade & Spade

(1) Parallel Groove

35

8T or 12K

16000

280

GES-8228A

GES-8229A

GET-6693A

9F59UBE241

23.0, Spade & Spade

Adapter & eyebolt terminal

35

8T or 12K

16000

280

GES-8228A

GES-8229A

GET-6693A

9F59UBE251

23.0, Spade & Spade

Adapter & parallel groove

35

8T or 12K

16000

280

GES-8228A

GES-8229A

GET-6693A

9F59UBE261

23.0, Spade & Spade

Eyebolt terminal & parallel groove

35

8T or 12K

16000

280

GES-8228A

GES-8229A

GET-6693A

9F59UBE271

23.0, Spade & Spade

(2) Eyebolt terminals

35

8T or 12K

16000

280

GES-8228A

GES-8229A

GET-6693A

9F59UBE281

23.0, Spade & Spade

(2) Parallel groove

35

8T or 12K

16000

280

GES-8228A

GES-8229A

GET-6693A

9F59UBE102

23.0, Spade & Stud

Without Hardware

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

9F59UBE112

23.0, Spade & Stud

(1) Adapter

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

9F59UBE122

23.0, Spade & Stud

(1) Eyebolt Terminal

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

9F59UBE132

23.0, Spade & Stud

(1) Parallel Groove

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

9F59UBE202

23.0, Spade & Spade

Without Hardware

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

9F59UBE212

23.0, Spade & Spade

(1) Adapter

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

9F59UBE222

23.0, Spade & Spade

(1) Eyebolt Terminal

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

9F59UBE232

23.0, Spade & Spade

(1) Parallel Groove

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

9F59UBE242

23.0, Spade & Spade

Adapter & eyebolt terminal

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

9F59UBE252

23.0, Spade & Spade

Adapter & parallel groove

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

9F59UBE262

23.0, Spade & Spade

Eyebolt terminal & parallel groove

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

9F59UBE272

23.0, Spade & Spade

(2) Eyebolt terminals

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

9F59UBE282

23.0, Spade & Spade

(2) Parallel groove

35

15T or 25K

70000

460

GES-8228A

GES-8229A

GET-6693A

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E

Sure Guard rated 23.0kV

E47

IEC Standard Back-Up Fuse-Links
3 / 7.2 kV – 6 / 12 kV – 10 / 17.5 kV – 10 / 24 kV – 20 / 36 kV
Ferrule German DIN Standard
Beyond our line of ANSI / IEEE current-limiting fuses, Mersen offers a full line of
medium voltage fuse links according to the IEC standards. Among them, the back-up
current-limiting fuse-links designed according to IEC 60 282-1 and meeting DIN 43
625 fuse-link dimensions. These fuse-links’ operating range is between their minimum
interrupting rating (I3) and their maximum interrupting rating (I1). When necessary,
we offer these fuses with a controlled power dissipation (CPD) feature. These type
CPD fuse-links, prevent overheating of the fuse compartment when installed in
conjunction with a load break switch.

Features/Benefits:
•• Conform to IEC 60-282-1 which is identical to German standard VDE 0670T4
•• Conform to DIN 43 625: High voltage fuse-links rated voltage 3.6 to 36kV
(Fuse-link dimensions)
•• Blown-fuse indicator: The strikers of the MV fuse-links mentioned here have an

Ratings:

effective length of 27mm and are a “medium type.” This classification results from

Size (L) 192:

the energy released by the striker during the first 20 mm of operating distance. The

Volts	

initial force is about 80N and the force at the end of the course (27mm) is 15N.

Amps	 : 2A to 200A

Highlights:

Applications:

•• Outdoor use

•• Protection of transformers and

•• High breaking capacity

distribution systems.

•• High current limitation

: 3/7.2kV AC

Size (L) 292:
Volts	

: 6/12kV AC

Amps	 : 1A to 200A
Size (L) 367:
Volts	

: 10/17.5kV AC

Amps	 : 6.3A to 100A

Definitions:
Back-up Fuse-links: Back-up fuse links have a rated minimum breaking capacity
current above which the fuses are able to interrupt current. Back-up fuses are not
designed to operate below their minimum breaking current (below I3). Their
operating range is between their minimum interrupting rating (I3) and their
maximum interrupting rating (I1). If protection is required for currents below I3,
additional protection must be provided.
Rated Voltage Range: Medium voltage fuse links must operate at the voltage
range for which they have been rated. When a current-limiting fuse clears a fault,
the element melts and an arc is formed across the gap. The higher the fuse voltage
rating, the higher the arc voltage will be and it will always be greater than the voltage
rating of the fuse. Replacing a fuse in equipment with a fuse of a higher voltage
rating can be destructive for the equipment. The rated voltage range provides the
permissible voltage limits top and bottom the fuse can be used at.
Breaking Capacity I1: The breaking capacity is also referred to as the “rated

Size (L) 442:
Volts	

: 10/24kV AC

Amps	 : 1A to 200A
Size (L) 537:
Volts	

: 20/36kV AC

Amps	 : 2A to 63A
Size (L) 292:
Volts	

: 6/12kV AC

Amps	 : 1A to 200A with CPD
Size (L) 442:
Volts	

: 10/24kV AC

Amps	 : 1A to 125A with CPD

maximum breaking current”. This is the maximum current which can be interrupted
by the fuse-link.

E48

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

IEC Standard Back-Up Fuse-Links
Definitions - Continued:
Minimum Breaking Capacity I3:
The minimum breaking current is referred to as the “rated minimum breaking current”. Back up fuses are not designed or
intended to open below I3.
Control Power Dissipation:
Due to abnormal circumstances such as lightening strikes or atypical transformer inrush, some of the fuse elements can be
damaged. The remaining elements will have to carry more current causing the fuse to dissipate significantly more heat. When
these fuses are enclosed in a narrow fuse compartment that has limited thermal power acceptance, there is risk this may be
exceeded. Type CPD fuse-links prevent such overheating. The CPD striker system releases the transformer switch before the
permissible power acceptance of the fuse compartment is exceeded. The fuse should then be replaced.

E

Accessories:
Mersen offers clips, indoor and outdoor fuse supports along with signaling systems:

Fuse clips:
Size 45mm with connection lug: Cat # MR45R
Size 45mm without the connection lug: Cat # MR55R
Flexible microswitch voltage range 12 / 36 kV:
1 NO/NC Ref # E092855
2 NO/NC Ref # F092856

Indoor and Outdoor Fuse Support:
Catalog No.

SI72V192

Indoor

outdoor

Voltage

Size L

(kV)

(mm)

7.2

192

Dielectric Whithstand (phase to ground)
50 Hz - 1min

1.2/50µs

kV RMS

peak voltage

20

Dimensions
A

B

C

D

E

F

60

400

226

322

347

175

270

SI120V292

12

292

28

75

424

324

200

445

175

270

SI175V292

17.5

292

38

95

424

324

200

445

220

315

SI175/367

17.5

367

38

95

576

401

270

522

218

313

SI240V442

24

442

50

125

576

476

270

597

270

365

SI360V537

36

537

70

170

670

570

350

691

354

449

SE120V292

12

292

28

75

424

324

200

445

261

356

SE175V292

17.5

292

38

95

424

324

200

445

261

356

SE175V367

17.5

367

38

95

576

401

270

521

263

358

SE240V442

24

442

50

125

576

476

270

597

309

404

SE360V537

36

537

70

170

670

570

350

691

381

476

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E49

IEC Standard Back-Up Fuse-Links
3 / 7.2 kV – 6 / 12 kV – 10 / 17.5 kV – 10 / 24 kV – 20 / 36 kV
Ferrule German DIN Standard
3 / 7.2 kV Rated Voltage Range – Back-up with Striker
Size: L = 192mm
Catalog No.

Ref #

IN (A)

D (mm)

Maximum breaking

Minimum breaking

current I1 (kA)

current I3 (A)

Weight (kg)

45DB72V2P

N1000098

2

56

63

15

1.1

45DB72V4P

P1000099

4

56

63

20

1.1

45DB72V6,3PD

S209293

6.3

56

63

20

1.1

45DB72V10PD

T209294

10

56

63

35

1.1

45DB72V16PD

V209295

16

56

63

64

1.1

45DB72V20PD

W209296

20

56

63

80

1.1

45DB72V25PD

X209297

25

56

63

95

1.1

45DB72V32PD

Y209298

31.5

56

63

110

1.1

45DB72V40PD

Z209299

40

56

63

134

1.1

45DB72V50PD

A209300

50

56

63

190

1.1

45DB72V63P

B209301

63

65

63

220

1.4

45DB72V80P

C209302

80

65

63

300

1.4

45DB72V100P

D209303

100

65

63

350

1.4

45DB72V125PD

Q1000100

125

88

63

435

2.4

45DB72V160P

R1000101

160

88

63

500

2.4

45DB72V200P

S1000102

200

88

63

610

2.4

Indoor fuse support: SI72V192

6 / 12 kV Rated Voltage Range – Back-up with Striker
Size: L = 292mm
Catalog No.

Ref #

IN (A)

D (mm)

Maximum breaking

Minimum breaking

current I1 (kA)

current I3 (A)

Weight (kg)

45DB120V1P

T1000103

1

56

63

14

1.7

45DB120V2P

V1000104

2

56

63

16

1.7

45DB120V4P

W1000105

4

56

63

22

1.7

45DB120V6,3P

F209305

6.3

56

63

30

1.7

45DB120V10P

G209306

10

56

63

42

1.7

45DB120V16P

H209307

16

56

63

54

1.7

45DB120V20P

J209308

20

56

63

73

1.7

45DB120V25P

K209309

25

56

63

93

1.7

45DB120V32P

L209310

31.5

56

63

105

1.7

45DB120V40P

M209311

40

56

63

125

1.7

45DB120V50P

N209312

50

56

63

160

1.7

45DB120V63P

P209313

63

56

63

230

1.7

45DB120V80P

Q209314

80

65

63

350

2.1

45DB120V100P

R209315

100

65

63

500

3.1

45DB120V125P

X1000106

125

88

63

480

3.7

45DB120V160P

Y1000107

160

88

63

560

3.7

45DB120V200P

Z1000108

200

88

63

610

3.7

Indoor fuse support: SI120V292 Outdoor fuse support: SE120V292

E50

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

IEC Standard Back-Up Fuse-Links
10 / 17.5 kV Rated Voltage Range – Back-up with Striker Size: L = 367mm
Catalog No.

Ref #

IN (A)

D (mm)

Maximum breaking

Minimum breaking

current I1 (kA)

current I3 (A)

Weight (kg)

45DB175V6,3P

V1000564

6.3

56

63

30

45DB175V10P

W1000565

10

56

63

43

2.1
2.1

45DB175V16P

X1000566

16

56

63

54

2.1

45DB175V20P

Y1000567

20

56

63

73

2.1

45DB175V25P

Z1000568

25

56

63

93

2.1
2.1

45DB175V32P

A1000569

31.5

56

63

105

45DB175V40P

B1000570

40

56

63

125

2.1

45DB175V50P

C1000571

50

56

63

205

2.1
2.1

D1000572

63

56

63

280

E1000573

80

65

63

350

2.6

45DB175V100P

F1000574

100

88

63

500

3.5

E

45DB175V63P
45DB175V80P

Indoor fuse support: SI175V367 Outdoor fuse support: SE175V367

10 / 24 kV Rated Voltage Range – Back-up with Striker Size: L = 442mm
Catalog No.

Ref #

IN (A)

D (mm)

Maximum breaking

Minimum breaking

current I1 (kA)

current I3 (A)

Weight (kg)

45DB240V1P

A1000109

1

56

63

14

2.5

45DB240V2P

B1000110

2

56

63

16

2.5

45DB240V4P

C1000111

4

56

63

23

2.5

45DB240V6,3P

S209339

6.3

56

63

30

2.5

45DB240V10P

T209340

10

56

63

43

2.5

45DB240V16P

V209341

16

56

63

54

2.5

45DB240V20P

W209342

20

56

63

73

2.5

45DB240V25P

X209343

25

56

63

93

2.5

45DB240V32P

Y209344

31.5

56

63

105

2.5

45DB240V40P

Z209345

40

56

63

125

2.5

45DB240V50P

A209346

50

56

63

205

2.5

45DB240V63P

B209347

63

56

63

280

2.5

45DB240V80P

C209348

80

65

63

310

3.1

45DB240V100P

D209349

100

78

63

430

4.2

45DB240V125P

D1000112

125

88

40

760

5.9

45DB240V160P

E1000113

160

88

31.5

900

5.9

45DB240V200P

F1000114

200

88

31.5

1050

5.9

Indoor fuse support: SI240V442 Outdoor fuse support: SE240V442

20 / 36 kV Rated Voltage Range – Back-up with Striker Size: L = 537mm
Maximum breaking

Minimum breaking

current I1 (kA)

current I3 (A)

56

31.5

15

2.7

56

31.5

20

2.7

6.3

56

31.5

20

2.7

T209363

10

56

31.5

33

2.7

45DB360V16PD

V209364

16

56

31.5

66

2.7

45DB360V20PD

W209365

20

56

31.5

95

2.7

45DB360V25PD

X209366

25

56

31.5

110

2.7

45DB360V32PD

Y209367

31.5

65

31.5

135

3.7

45DB360V40PD

Z209368

40

65

20

200

3.7

45DB360V50PD

J1000117

50

88

20

220

6.5

45DB360V63PD

K1000118

63

88

20

280

6.5

Catalog No.

Ref #

IN (A)

D (mm)

45DB360V2P

G1000115

2

45DB360V4P

H1000116

4

45DB360V6,3PD

S209362

45DB360V10PD

Weight (kg)

Indoor fuse support: SI360V537 Outdoor fuse support: SE360V537

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E51

IEC Standard Back-Up Fuse-Links
6 / 12 kV – 10 / 24 kV
Ferrule German DIN standard with Control Power Dissipation (CPD) striker system
6 / 12 kV Rated Voltage Range – Back-up with CPD Striker Size: L = 292mm
Catalog No.

Ref #

IN (A)

D (mm)

Maximum breaking

Minimum breaking

current I1 (kA)

current I3 (A)

Weight (kg)

45DB120V1PT

L1000119

1

56

63

14

1.6

45DB120V2PT

M1000120

2

56

63

16

1.6

45DB120V4PT

N1000121

4

56

63

22

1.6

45DB120V6,3PT

P1000122

6.3

56

63

30

1.6

45DB120V10PT

Q1000123

10

56

63

42

1.6

45DB120V16PT

R1000124

16

56

63

54

1.6

45DB120V20PT

S1000125

20

56

63

73

1.6

45DB120V25PT

T1000126

25

56

63

93

1.6

45DB120V32PT

V1000127

31.5

56

63

105

1.6

45DB120V40PT

W1000128

40

56

63

125

1.6

45DB120V50PT

X1000129

50

56

63

160

1.6

45DB120V63PT

Y1000130

63

56

63

230

1.6

45DB120V80PT

Z1000131

80

65

63

350

2.1

45DB120V100PT

A1000132

100

65

63

500

2.1

45DB120V125PT

B1000133

125

88

63

480

3.7

45DB120V160PT

C1000134

160

88

63

560

3.7

45DB120V200PT

D1000135

200

88

63

610

3.7

Indoor fuse support: SI120V292 Outdoor fuse support: SE120V292

10 / 24 kV Rated Voltage Range – Back-up with CPD Striker Size: L = 442mm
Catalog No.

Ref #

IN (A)

D (mm)

Maximum breaking

Minimum breaking

current I1 (kA)

current I3 (A)

Weight (kg)

45DB240V1PT

E1000136

1

56

63

14

2.3

45DB240V2PT

F1000137

2

56

63

16

2.3

45DB240V4PT

G1000138

4

56

63

23

2.3

45DB240V6,3PT

H1000139

6.3

56

63

30

2.3

45DB240V10PT

J1000140

10

56

63

43

2.3

45DB240V16PT

K1000141

16

56

63

54

2.3

45DB240V20PT

L1000142

20

56

63

73

2.3

45DB240V25PT

M1000143

25

56

63

93

2.3

45DB240V32PT

N1000144

31.5

56

63

105

2.3

45DB240V40PT

P1000145

40

56

63

125

2.3

45DB240V50PT

Q1000146

50

56

63

205

2.3

45DB240V63PT

R1000147

63

56

63

280

2.3

45DB240V80PT

S1000148

80

65

63

310

3.1

45DB240V100PT

T1000149

100

78

63

430

4.1

45DB240V125PT

V1000150

125

88

40

760

5.9

Indoor fuse support: SI240V442 Outdoor fuse support: SE240V442

E52

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Accessories Type EK 9F61 Series
Fuse supports, fuse disconnect switches and accessories from 2.4kV to 38kV

Indoor:
	
Fuse supports: 		
	
Fuse disconnect switches:	
Outdoor:
	
Fuse supports: 		
	
Fuse disconnect switches:	

EK-1
EK-3
EKO-1
EKO-3

The letter suffix following the (-1) or the (-3) shows the fuse size.

Fuse Size

Ferrule Diameter

B

1-9/16 inches

C

2 inches

D

3inches

DD

two-3 inch in parrallel

DDDD

four-3 inch in parrallel

EE

two-4 inch in parrallel

E

Fuse supports, non-disconnecting, are used primarily in potential transformer circuits, or where there is some
other disconnecting or isolating device in series with the fuse in the circuit. Disconnecting switch devices have the
additional feature of serving to isolate the equipment they protect. It should be noted that disconnecting switches are
not load-breaking devices, therefore, the circuit must be open prior to the fuse disconnection. Select either a fuse
support or a disconnecting switch for each fuse. Fuse supports and disconnecting switches include live parts for both
ends. Both fuse supports and fuse disconnect switches can be mounted vertically or horizontally. The type EK are
used for indoor installations while the type EKO are used outdoors.

When selecting a mounting for a current-limiting fuse, it is necessary that the clip centers and size agree with the
fuse selected.
For further detailed information regarding these fuse supports and disconnecting switches such as storage, mounting
and maintenance, please refer to INST-EK39196 available on our website at us-ferrazshawmut.mersen.com or ask
your sales representative for a hard copy.

Fuse Support - EK-1 Indoor

EK-1B

EK-1DD

EK-1C

EK-1EE

EK-1D

EK-1DDDD

Refer to drawings for specific dimensions.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E53

Accessories Type EK 9F61 Series
Fuse Support - EK-1 Indoor
Catalog No.

E54

Max. kV

Ferrule Size/

Clip

Spare Parts

Diam.

Centers

(Live Parts)

Insulator Rating
Spare Parts (Clips)

- Class/NEMA
Nominal Sys. (kV)

Insulator Rating BIL (kV)

Insulator Rating Class/NEMA
Tech Ref.

9F61ABB101

2.75/5.5

B/1.56”

8.12”

9F61BNW450

9F61BWW460

4.8

60

A-20

9F61ABG101

8.25

B/1.56”

8.12”

9F61BNW450

9F61BWW460

13.8

95

A-20

9F61ADG101

15.5

B/1.56”

11.5”

9F61BNW450

9F61BWW460

13.8

95

A-20

9F61ADJ101

15.5

B/1.56”

11.5”

9F61BNW450

9F61BWW460

14.4

110

A-20

9F61AAB201

2.75

C/2.00”

7”

9F61BNW451

9F61BWW457

4.8

60

A-20

9F61ACB201

5.5

C/2.00”

9”

9F61BNW451

9F61BWW457

4.8

60

A-20

9F61AEG201

15.5

C/2.00”

12”

9F61BNW451

9F61BWW457

13.8

95

A-20

9F61AGG201

15.5

C/2.00”

15”

9F61BNW451

9F61BWW457

13.8

95

A-20

9F61AGJ201

15.5

C/2.00”

15”

9F61BNW451

9F61BWW457

14.4

110

A-20

9F61AHM201

25.8

C/2.00”

21”

9F61BNW743

9F61BWW457

23

150

A-20

9F61AAB301

2.75

D/3.00”

7”

9F61BNW750

9F61BWW459

4.8

60

A-20

9F61AEB301

2.75/5.5

D/3.00”

12”

9F61BNW750

9F61BWW459

4.8

60

A-20

9F61AEG301

8.25

D/3.00”

12”

9F61BNW750

9F61BWW459

13.8

95

A-20

9F61AGG301

15.5

D/3.00”

15”

9F61BNW750

9F61BWW459

13.8

95

A-20

9F61AGJ301

15.5

D/3.00”

15”

9F61BNW750

9F61BWW459

14.4

110

A-20

9F61AHM301

25.8

D/3.00”

21”

9F61BNW744

9F61BWW459

23

150

A-20

9F61AAB401

2.75

DD/3.00”

7”

9F61BNW751

–

4.8

60

A-20

9F61AEB401

2.75/5.5

DD/3.00”

12”

9F61BNW751

–

4.8

60

A-20

9F61AEG401

8.25

DD/3.00”

12”

9F61BNW751

–

13.8

95

A-20

9F61AGG401

15.5

DD/3.00”

15”

9F61BNW751

–

13.8

95

A-20

9F61AGJ401

15.5

DD/3.00”

15”

9F61BNW751

–

14.4

110

A-20

9F61AHM401

25.8

DD/3.00”

21”

9F61AWW738

–

23

150

A-20

9F61AFB501

5.08

EE/4.00”

14.12”

9F61BNW452

–

4.8

60

A-20

9F61AFG501

15

EE/4.00”

14.12”

9F61BNW452

–

13.8

95

A-20

9F61AFJ501

15

EE/4.00”

14.12”

9F61BNW452

–

14.4

110

A-20

9F61AHG001

DDDD

For Bolted-end Fuses refer to drawings.

9F61AHJ001

DDDD

For Bolted-end Fuses refer to drawings.

9F61AKB001

DDDD

For Bolted-end Fuses refer to drawings.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Accessories Type EK 9F61 Series

EK-3C

EK-3D

E

Disconnect Switch - EK-3 Indoor

EK-3DD

Spare Parts

Spare Parts

Insulator Rating -

Insulator Rating -

Insulator Rating -

(Live Parts)

(Clips)

Nominal Sys. (kV)

BIL (kV)

Class/NEMA Tech Ref.

7”

9F61BNW731

9F61BWW457

4.8

60

A-20

C/2.00”

9”

9F61BNW731

9F61BWW457

4.8

60

A-20

15.5

C/2.00”

12”

9F61BNW731

9F61BWW457

13.8

95

A-20

9F61AGG205

15.5

C/2.00”

15”

9F61BNW731

9F61BWW457

13.8

95

A-20

9F61AGJ205

15.5

C/2.00”

15”

9F61BNW731

9F61BWW457

14.4

110

A-20

9F61AHM205

25.8

C/2.00”

21”

9F61BNW746

9F61BWW457

23

150

A-20

9F61AAB305

2.75

D/3.00”

7”

9F61BNW732

9F61BWW459

4.8

60

A-20

9F61AEB305

2.75/5.5

D/3.00”

12”

9F61BNW732

9F61BWW459

4.8

60

A-20

9F61AEG305

8.25

D/3.00”

12”

9F61BNW732

9F61BWW459

13.8

95

A-20

9F61AGG305

15.5

D/3.00”

15”

9F61BNW732

9F61BWW459

13.8

95

A-20

9F61AGJ305

15.5

D/3.00”

15”

9F61BNW732

9F61BWW459

14.4

110

A-20

9F61AHM305

25.8

D/3.00”

21”

9F61BNW747

9F61BWW459

23

150

A-20

9F61AAB405

2.75

DD/3.00”

7”

9F61BNW461

–

4.8

60

A-20

9F61AEB405

2.75/5.5

DD/3.00”

12”

9F61BNW461

–

4.8

60

A-20

9F61AEG405

8.25

DD/3.00”

12”

9F61BNW461

–

13.8

95

A-20

9F61AGG405

15.5

DD/3.00”

15”

9F61BNW461

–

13.8

95

A-20

9F61AGJ405

15.5

DD/3.00”

15”

9F61BNW461

–

14.4

110

A-20

9F61AHM405

25.8

DD/3.00”

21”

9F61BNW748

–

23

150

A-20

Ferrule Size/

Catalog No.

Max. kV

9F61AAB205

2.75

C/2.00”

9F61ACB205

5.5

9F61AEG205

Diam.

Clip Centers

Refer to drawings for specific dimensions.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E55

Accessories Type EK 9F61 Series
Fuse Support - EKO-1 Outdoor

EKO-1C

EKO-1D

EKO-1DD

EKO-1DDDD

							

Ferrule

Clip

Spare Parts

Spare Parts

Insulator Rating -

Insulator Rating -

Insulator Rating -

Size/Diam.

Centers

(Live Parts)

(Clips)

Nominal Sys. (kV)

BIL (kV)

Class/NEMA Tech Ref.

2.75/5.5/8.25

C/2.00”

12”

9F61BNW743

9F61BWW457

7.5

95

202

15.5

C/2.00”

15”

9F61BNW743

9F61BWW457

15

110

205

Catalog No.

Max. kV

9F61CEF209
9F61CGL209
9F61CHM209

25.8

C/2.00”

21”

9F61BNW743

9F61BWW457

23

150

208

9F61CEF309

2.75/5.5/8.25

D/3.00”

12”

9F61BNW744

9F61BWW459

7.5

95

202

9F61CGL309

15.5

D/3.00”

15”

9F61BNW744

9F61BWW459

15

110

205

9F61CHM309

25.8

D/3.00”

21”

9F61BNW744

9F61BWW459

23

150

208

9F61CJN309

38

D/3.00”

27”

9F61BNW744

9F61BWW459

34.5

200

210

9F61CEF409

2.75/5.5/8.25

DD/3.00”

12”

9F61AWW738

–

7.5

95

202

9F61CGL409

15.5

DD/3.00”

15”

9F61AWW738

–

15

110

205

9F61CHM409

25.8

DD/3.00”

21”

9F61AWW738

–

23

150

208

9F61CJN409

38

DD/3.00”

27”

9F61AWW738

–

34.5

200

210

9F61CHL009

DDDD

For Bolted-end Fuses refer to drawings.

9F61CKF009

DDDD

For Bolted-end Fuses refer to drawings.

Refer to drawings for specific dimensions.

E56

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Accessories Type EK 9F61 Series

E

Disconnect Switch - EKO-3 Outdoor

EKO-3C

EKO-3D Open Position

EKO-3DD
Insulator Rating -

Ferrule

Clip

Spare Parts

Spare Parts

Insulator Rating -

Insulator Rating -

Size/Diam.

Centers

(Live Parts)

(Clips)

Nominal Sys. (kV)

BIL (kV)

2.75/5.5/8.25

C/2.00”

12”

9F61BNW746

9F61BWW457

7.5

95

202

9F61CGL210

15.5

C/2.00”

15”

9F61BNW746

9F61BWW457

15

110

205

9F61CGN210

15.5

C/2.00”

15”

9F61BNW746

9F61BWW457

34.5

200

210

9F61CHM210

25.8

C/2.00”

21”

9F61BNW746

9F61BWW457

23

150

208

9F61CEF310

2.75/5.5/8.25

D/3.00”

12”

9F61BNW747

9F61BWW459

7.5

95

202

9F61CGL310

15.5

D/3.00”

15”

9F61BNW747

9F61BWW459

15

110

205

9F61CHM310

25.8

D/3.00”

21”

9F61BNW747

9F61BWW459

23

150

208

9F61CJN310

38

D/3.00”

27”

9F61BNW747

9F61BWW459

34.5

200

210

9F61CEF410

2.75/5.5/8.25

DD/3.00”

12”

9F61BNW748

–

7.5

95

202

9F61CGL410

15.5

DD/3.00”

15”

9F61BNW748

–

15

110

205

9F61CHM410

25.8

DD/3.00”

21”

9F61BNW748

–

23

150

208

9F61CJN410

38

DD/3.00”

27”

9F61BNW748

–

34.5

200

210

Catalog No.

Max. kV

9F61CEF210

Class/NEMA
Tech Ref.

Refer to drawings for specific dimensions.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E57

Accessories Type EK 9F61 Series
Accessories and Spare Parts
Hinge Trunions and Operating Eyes for Use on Disconnecting Switches
Fuse Size

Hinge Trunion Model No.

Operating Eye Model No.

C

9F61BJW397

9F61BFW394

D

9F61BKW398

9F61AWW612

DD

9F61BLW399

9F61AWW612

EK-3C
9F61BFW394

EK-3D and DD
9F61AAW612

EKO-3C
9F61BJW397

EKO -3D
9F61BKW398

EKO-3DD
9F61BLW399

E58

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Accessories Type EK 9F61 Series
Fuse Size B (Ferrule Diameter 1.5625”)
Fuse Supports &
Disconnect Switches

Spare Live Parts(*)

Figure (Fig.)

Spare Fuse Clips(**)

Figure (Fig.)

9F61ABB101

Fuse size

B

9F61ABG101

B
9F61BNW450

9F61BWW460

9F61ADG101

B

9F61ADJ101

B

Fuse Supports &
Disconnect Switches

Spare Live Parts(*)

Figure (Fig.)

E

Fuse Size C (Ferrule Diameter 2”)
Spare Fuse Clips(**)

Figure (Fig.)

Fuse size

9F61AAB201

C

9F61ACB201

C

9F61AEG201

9F61BNW451

C

9F61AGG201

C

9F61AGJ201

C

9F61AAB205

C

9F61ACB205

C

9F61AEG205

9F61BNW731

C

9F61AGG205

C
9F61BWW457

9F61AGJ205

C

9F61AHM201

C

9F61CEF209

C
9F61BNW743

9F61CGL209

C

9F61CHM209

C

9F61AHM205

C

9F61CEF210

C
9F61BNW746

9F61CGL210

C

9F61CHM210

C

(*) Spare Live Parts: Order (1) Live Parts for each Fuse Support and Disconnecting Switch (includes live parts for both ends).
(**) Fuse Clips: Order (2) Fuse Clips for each Fuse Support and order (1) Fuse Clip for each Disconnecting Switch.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E59

Accessories Type EK 9F61 Series
Fuse Size D (Ferrule Diameter 3”)
Fuse Supports &
Disconnect Switches

Spare Live Parts(*)

Figure (Fig.)

Spare Fuse Clips(**)

Figure (Fig.)

Fuse size

9F61AAB305

D

9F61AEB305

D

9F61AEG305

D

9F61BNW732

9F61AGG305

D

9F61AGJ305

D

9F61AHM301

D

9F61CEF309

D

9F61CGL309

9F61BNW744

D

9F61CHM309

D

9F61CJN309

D
9F61BWW459

9F61AHM305

D

9F61CEF310

D

9F61CGL310

9F61BNW747

D

9F61CHM310

D

9F61CJN310

D

9F61AAB301

D

9F61AEB301

D

9F61AEG301

9F61BNW750

D

9F61AGG301

D

9F61AGJ301

D

(*) Spare Live Parts: Order (1) Live Parts for each Fuse Support and Disconnecting Switch (includes live parts for both ends).
(**) Fuse Clips: Order (2) Fuse Clips for each Fuse Support and order (1) Fuse Clip for each Disconnecting Switch.

For the 3” ferrule diameter we also offer the Cat # 228-700-530
clips. These spring reinforced clips will accomodate one and
two barrel 3-inch diameter medium voltage ferrule type fuses.
The clip and reinforcing spring are intended to be bolted to a
copper busbar through two .41” and 1.06” slots. A minimum
copper-bus section of 1/4” x 1-1/2” is recommended for
maximum ratings of 24R and 450E. The Cat # 228-700-530 is
for one pair of clips, enough for one fuse.

E60

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Accessories Type EK 9F61 Series
Fuse Size DD (Ferrule Diameter two 3” in Parallel)
Spare Live Parts(*)

Figure (Fig.)

Spare Fuse Clips(**)

Fuse size

9F61AHM401

DD

9F61CEF409

DD
9F61AWW738

9F61CGL409

DD

9F61CHM409

DD

9F61CJN409

DD

9F61AAB405

DD

9F61AEB405

DD

9F61AEG405

DD

9F61BNW461

9F61AGG405

E

Fuse Supports & Disconnect Switches

DD

9F61AGJ405

DD

N/A

9F61AHM405

DD

9F61CEF410

DD

9F61CGL410

DD

9F61BNW748

9F61CHM410

DD

9F61CJN410

DD

9F61AAB401

DD

9F61AEB401

DD

9F61AEG401

DD

9F61BNW751

9F61AGG401

DD

9F61AGJ401

DD

Conversion Kit D to DD for use on Fuse Supports
Model No.

Figure (Fig.)

Used on live parts

Figure (Fig.)

9F61BNW751 (Indoor)
9F61BNW402
9F61AWW738 (Outdoor)

Fuse Size EE (Ferrule Diameter Two 4” in Parallel)
Fuse Supports & Disconnect Switches

Spare Live Parts(*)

Figure (Fig.)

Spare Fuse Clips(**)

EE

9F61AFB501
9F61AFG501

Fuse size

9F61BNW452

N/A

9F61AFJ501

EE
EE

(*) Spare Live Parts: Order (1) Live Parts for each Fuse Support and Disconnecting Switch (includes live parts for both ends).
(**) Fuse Clips: Order (2) Fuse Clips for each Fuse Support and order (1) Fuse Clip for each Disconnecting Switch.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

E61

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

International Fuses
A world of circuit protection solutions — in your backyard

Your problem:
customers,
globalization isn’t
just a buzzword

F

International Fuses

EURO/IEC Fuses

it’s a reality with

• gl-gG, aM...........................................F2

very tangible chal-

• D0 type (NEOZED)............................F7

lenges for those in
charge of purchasing, inventory, installations, repairs, and other operational duties.

• D type (DIAZED)..............................F11
• NH Dimension / gl-gG, aM...............F15

And that’s true whether you’re building, operating, or maintaining
overseas manufacturing centers. Exporting equipment designed
to be acceptable to overseas inspection authorities and electrical professionals. Or ensuring imported equipment is optimally
installed and maintained.

Canadian Fuses
• Class C.............................................F20
• Class CA & CB, CN/CNS.................F22
• HRCII NIT/NS...................................F23

Our solution: Mersen offers you the benefits of a truly global
supplier. From the one-stop shopping advantages of our complete
line of European and North American fuses, holders, and acces-

• Class H NRN/NRS...........................F24
• Class H CRN/CRS...........................F25

sories. To our pursuit of other international technologies. To our
definitive understanding of international circuit protection standards such as those of the IEC and CENELEC.
Want more information fast? For more technical or applicationspecific information, please call our International Fuse experts, at
978-462-6662; 416-252-9371 in Canada; or visit our website at
us-ferrazshawmut.mersen.com.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

F

For most of our

gl-gG, aM Cylindrical Fuse-Links
Domestic and industrial cylindrical fuse-links
Mersen gI-gG and aM fuse-links cover a wide range of physical sizes and ampere
ratings for 400, 500, and 690 volts AC. gI-gG and aM fuse-links are for industrial
applications. Most ratings are available with an optional indicator. All industrial fuselinks have the option of a built-in striker. All cylindrical fuse-links have ceramic bodies
and silver-plated ferrules.

gI-gG

gI-gG

Full Range Protection

Full Range Protection
Fuse-links with Striker

•• 4 physical sizes from 8 x 31mm
to 22 x 58 mm
•• 400, 500 and 690 Volt ratings 0.5A through 125A
•• Most ratings available with
indicator
•• Meet IEC, NFC and UNE
standards
•• Approved by Lloyds Register of
Shipping and Bureau Veritas

•• 2 sizes-14 x 51mm and
22 x 58mm

•• 400, 500 and 690 Volt ratings
- 4A through 125A
•• All ratings include striker
•• Meet IEC, NFC and UNE
standards
•• Approved by Lloyds Register
of Shipping and Bureau
Veritas

aM

aM

Short Circuit Protection

Short Circuit Protection
Fuse-links with Striker

•• 4 physical sizes from 8 x 31mm
to 22 x 58mm

•• 2 sizes - 14 x 51mm and

•• 400, 500 and 690 Volt ratings 16A through 125A
•• Most ratings available with
indicator

2A through 125A
•• All ratings include striker

•• Meet IEC, NFC and UNE
standards

F2

22 x 58mm
•• 400, 500 and 690 Volt ratings -

•• Meet IEC, NFC and UNE
standards

•• Approved by Lloyds Register of

•• Approved by Lloyds Register of

Shipping and Bureau Veritas

Shipping and Bureau Veritas

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

gl-gG Cylindrical Fuse-Links
Catalog Numbers, Ratings – gI-gG (Optional Blown-Fuse Indicator)
Rated In

Rated

(mm x mm)

Current (A)

Voltage

8x31

10x38

15009-G

1

15011-G

2

15013-G

15213-G

4

15019-G

15219-G

6

15023-G

15223-G

15027-G

15227-G

10

15031-G

15231-G

12

15033-G

15233-G

16

15035-G

15235-G

20

15037-G

15237-G

25

15039-G

15239-G

0.5

16009-G

1

16011-G

2

16013-G

16213-G

4

16019-G

16219-G

6

16023-G

16223-G

16027-G

16227-G

12

16031-G

16231-G

16

16033-G

16233-G

20

16035-G

16235-G

25

16037-G

16237-G

32

16039-G

16239-G

16043-G

16243-G

8

400V

8

500V

400V

1

17011-G

2

17013-G

4

17019-G

6

17023-G

8

Interrupting

Standard

Rating (A)

Pack/Ctn

20,000

10/100

15037-G

16037-G

120,000

10/100

80,000

10/50

17027-G

690V

10

17031-G

12

17033-G

16

17035-G

20

17037-G

25

17039-G

17039-G

32

17043-G

500V

40
50

17047-G

400V

120,000

17051-G

2

18013-G

4

18019-G

6

18023-G

8

18027-G

10

18031-G

12

18033-G

16
22x58

w Indicator

0.5

0.5

14x51

Catalog Number
w/o Indicator

F

Size

18035-G

20

690V

18037-G

25

18039-G

32

18043-G

40

18047-G

50

18051-G

63

18055-G

80

80,000

10/50

18059-G

18059-G

100

500V

18063-G

125

400V

18065-G

120,000

Dimensions (mm)
Fuse Size

A

B

C

8 x 31

8.5

31.5

6.3

10 x 38

10.3

38

10.5

14 x 51

14.3

51

13.8

22 x 58

22.2

58

16.2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

F3

gl-gG Cylindrical Fuse-Links
Catalog Numbers, Ratings – gI-gG with Striker
Rated In

Size
(mm x mm)

Current
(A)

Rated

Catalog

Interrupting

Standard

Voltage

Number

Rating (A)

Pack/Ctn

2

17413-G

4

17419-G

6

17423-G

8

17427-G

10

17431-G
500V

12

14x51

17433-G

16

17435-G

20

17437-G

25

17439-G

32

17443-G

40

120,000

10/50

17447-G

50

400V

18419-G

6

18423-G

8

18427-G

10

18431-G

18447-G

Striker

17451-G

4

12

Before

18433-G
690V

16
22x58

17447-G

18435-G

20

18437-G

25

18439-G

32

18443-G

40

18447-G

50

18451-G

63

500V

18455-G

80

500V

18459-G

100

500V

18463-G

125

400V

18465-G

80,000
10x50

Fuse Construction
1 Ceramic body
2 Sand
3 Indicator contact
4 Lower contact
5 Contact ring

120,000

6 Melting element
7 Indicator

Dimensions (mm)
Fuse Size

A

C

D

E

14 x 51

14.3

51

B

13.8

7.5

3.8

22 x 58

22.2

58

16.2

7.5

3.8

D

A

E

C

F4

B

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

After

aM Cylindrical Fuse-Links
Catalog Numbers, Ratings – aM (Optional Blown-Fuse Indicator)
Rated In

Rated

(mm x mm)

Current (A)

Voltage

8x31

10x38

Catalog Number
w/o Indicator

1

15511-G

2

15513-G

4

15519-G

400V

6

15527-G

10

15531-G
16503-G

0.25

16507-G

0.5

16509-G

1

16511-G

16711-G

2

16513-G

16713-G

4

16519-G

16719-G

6

16523-G

16723-G

16527-G

16727-G

10

16531-G

16731-G

12

16533-G

16733-G

16

16535-G

16735-G

20

16537-G

16737-G

16539-G

16739-G

500V

400V

32
0.25

17507-G
17509-G

1

17511-G

2

17513-G

4

17519-G

6

17523-G

8

17527-G
690V

10/100

16535-G

120,000

10/100

17535-G
80,000

17531-G

12

17533-G

16

17535-G

20

17537-G

25

17539-G

32

10/50

17543-G

40

500V

17547-G

45

120,000

17549-G

50

400V

17551-G

4

18519-G

6

18523-G

8

18527-G

10

18531-G

12

18533-G

16

18535-G

20
22x58

Pack/Ctn

16543-G

0.5

10

Standard

Rating (A)

20,000

0.16

8

Interrupting

15519-G

15523-G

8

25

14x51

w Indicator

F

Size

18537-G

25

690V

18539-G

32

18543-G

40

18547-G

50

18551-G

63

18055-G

80

80,000

18555-G

10/50

18559-G

100

500V

18563-G

125

400V

18565-G

120,000

Dimensions (mm)
Fuse Size

A

B

C

8 x 31

8.5

31.5

6.3

10 x 38

10.3

38

10.5

14 x 51

14.3

51

13.8

22 x 58

22.2

58

16.2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

F5

aM Cylindrical Fuse-Links
Catalog Numbers, Ratings – aM with Striker
Size

Rated In

Rated

Catalog

Interrupting

Standard

(mm x mm)

Current (A)

Voltage

Number

Rating (A)

Pack/Ctn

1

17911-G

2

17913-G

4

17919-G

6

17923-G

8

17927-G

10
14 X 51

500V

17931-G

12

17933-G

16

17935-G

20

17937-G

25

17939-G

32

17943-G

40

17947-G

45

17949-G

50

400V

120,000

10/50

18951-G

17951-G

4

18919-G

6

18923-G

8

18927-G

10

18931-G

12

18933-G

16

Striker

18935-G

20
22 X 58

17947-G

690V

80,000

18937-G

25

18939-G

32

18943-G

40

18947-G

50

18951-G

63

BEFORE

10/50

AFTER

18955-G

80

500V

100

18959-G
18963-G

400V

125

120,000

18965-G

D

Dimensions (mm)
Fuse Size

F6

A

B

C

D

E

14 x 51

14.3

51

13.8

7.5

3.8

22 x 58

22.2

58

16.2

7.5

3.8

A

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

E

C

B

www.barr-thorp.com

DO Type (NEOZED)
400 Volt DO Type NEOZED fuse-links, screw caps and fuse
bases
Mersen DO fuse-links, also called Neozed type, are 400 Volts AC rated with 100kA
interrupting rating. They have 3 physical sizes, DO1, DO2, and DO3 and fit into
special screw caps. All fuse-links have blown-fuse indicators which are visible through
the screw cap when mounted. Screw caps fit onto single and three-pole bases which
are screw or DIN rail mounted. All accessories such as covers and gauge rings are
described.

Size

DO1

DO2

DO3

Rated

Catalog

Reference

Gauge

Standard

Current

Number

Number

Color

Pack/Ctn.

2

1700.002-L

T214676

Pink

4

1700.004-L

W200809

Brown

6

1700.006-L

B215695

Green

10

1700.010-L

W211090

Red

16

1700.016-L

R223023

Grey

20

1701.020-L

B217742

Blue

25

1701.025-L

W213160

Yellow

35

1701.035-L

R219826

Black

50

1701.050-L

D215191

White

63

1701.063-L

C201873

Copper

80

1702.080-L

L216716

Silver

100

1702.100-L

N212647

Red

50

Ratings:
Volts	

: 400VAC

	

: 250VDC

F

DO Type NEOZED Fuses, 400VAC, 250VDC gG

Amps	 : 2 to 100A
50

I.R.	

: 100kA I.R.

10

DO Type NEOZED Fuses, 400VAC, aM
DO2

20

1701.0205-L

H211607

Blue

25

1701.0255-L

F212640

Yellow

35

1701.0355-L

J213655

Black

10

Approvals:
Dimensions (mm)
DO1

DO2

DO3

A

11

15

24

B

36

36

43

•• Meet IEC, VDE standards:
IEC	 269-3, 3A	
VDE	 0636

Fuse Construction
1 Ceramic body
2 Sand
3 Upper contact
4 Contact top
5 Lower contact
6 Melting element
7 Indicator

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

F7

DO Type (NEOZED)
DO NEOZED Screw Caps - Plastic, 400VAC
Size

Rated Current

Cap Thread

Catalog Number

Reference Number

Standard Pack/Ctn.
20

With Test Hole
DO1

16

E14

1714.0002-L

E212501

DO2

63

E18

1715.0002-L

P211981

With Sealable Hole and Testing Hole
DO1

16

E14

11714.00022-L

R214536

DO2

63

E18

11715.00022-L

S214537

20

E18

1715-L

L206435

20

20

Without Test Hole
DO2

63

Screw Cap - Porcelain, 400VAC
With Test Hole
DO1

16

E14

1710.0002-L

H201211

DO2

63

E18

1711.0002-L

T215044

M30 x 2

1712.0002-L

V215045

Without Test Hole
DO3

100

20

DO NEOZED Gauge Rings
Size

DO1

DO2

DO3

Rated

Catalog

Reference

Gauge

Standard

Current

Number

Number

Color

Pack/Ctn.

2

1705.002-L

J216576

Pink

4

1705.004-L

J219681

Brown

6

1705.006-L

P206438

Green

10

1705.010-L

M213014

Red

2

1706.002-L*

K216577*

Pink

4

1706.004-L*

S222127*

Brown

6

1706.006-L*

R211983*

Green

10

1706.010-L*

H216069*

Red

16

1706.016-L*

Q218629*

Grey

20

1706.020-L

S200668

Blue

25

1706.025-L

R213524

Yellow

35

1706.035-L

J216070

Black

50

1706.050-L

R218630

White

80

1707.080-L

T200669

Silver

50

25

* For use of D01 fuses in D02 bases

D0 NEOZED Insulating covers
Single Pole for Ceramic Fuse Bases:

F8

Catalog Number

Reference Number

Standard Pack/Ctn.

D01/D02 With marking area

1718.7-L

V200670

50

D03 Without marking area

1728-L

V211986

D01/D02 Cover - cap

1721.03-L

X201730

D01/D02 With marking area (3-pole)

1732.7-L

M216579

20

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

DO Type (NEOZED)
D0 NEOZED Fuse Bases
Screw mounting without shock-proof protection cover, 400 VAC
Rated Current

D01

16

D02

63

D02

63

D03

100

50

D01

16

4

D02

63

D02

63

Sect. mm2
4

1

3

25

25

Catalog Number

Reference

Standard

Number

Pack/Ctn.

1720.1-L

Z216061

1721.2-L

M214532

1721.4-L

F213008

1722.4-L

J213011

1730.1-L

K200661

1731.2-L

F216573

1731.4-L

K206365

20
10
5

Snap-on fastening without shock-proof protection cover, 400 VAC			
					
Size

Rated Current

D01

16

D02

63

D02

63

D03

100

D01

16

D02

63

D02

63

Pole

Max Cross
Sect. mm2
4

1

3

Catalog Number

Reference

Standard

Number

Pack/Ctn.

1720.15-L

J200660

1721.25-L

J218623

1721.45-L

W215552

50

1722.45-L

Q214535

4

1730.15-L

B216063

1731.252-L

Y217601

1731.452-L

M211979

25

25

F

Pole

Max Cross

Size

20
10
5

Snap-on fastening with shock-proof protection cover, 400 VAC			
					
Size

Rated Current

D01
D01

16

D01

D02

Sect. mm2
4

1
63

25
3

D02
D03

1

Max Cross

3

D02
D02

Pole

100

1

50

Catalog Number

Reference

Standard

Number

Pack/Ctn.

1720.17-L

B211463

1721.37-L

T215550

1730.172-L

219144

1721.27-L

M200663

1721.47-L

K218624

1731.272-L

E222874

1731.472-L

K213518

1722.47-L

F216057

20
5
20
5
10

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

F9

DO Type (NEOZED)
D0 NEOZED Accessories
Special Holding Spring
Size

Catalog Number

Reference Number

Standard Pack/Ctn.

D01 Fuse in D02 socket

1713-L

Z215049

50

D02 Fuse in D03 socket

1709-L

P214028

10

Spacer
Size

Catalog Number

Reference Number

Standard Pack/Ctn.

D02 fuse in D03 socket

1707-L

T211985

10

Gauge Ring Key
Size

Catalog Number

Reference Number

Standard Pack/Ctn.

Gauge rings D01, D02, D03

1708-L

J212505

10

Reference Number

Standard Pack/Ctn.

1716-L

X222936

1

1716.333-L

F200726

1

Screw Cap Remover
Size
Plastic screw caps D01, D02

F10

Catalog Number

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D Type (DIAZED)
500 VOLT D type DIAZED fuse-links, screw caps and fuse
bases
Mersen D fuse-links, also called Diazed type, are 500 Volts AC rated with 75kA
interrupting rating. They have 4 physical sizes, DI, DII, DIII, and DIV and fit into
special screw caps. All fuse-links have blown-fuse indicators which are visible
through the screw cap. Screw caps fit onto single pole bases which are screw or DIN
rail mounted. All accessories such as covers, adapter rings, and gauge rings are

Ratings:

D Type DIAZED Fuse Bases, Snap-on
Size

Rated Current

Pole

Max Cross

Catalog

Reference

Standard

Sect. mm²

Number

Number

Pack/Ctn
15

Snap-on fastening, 500 VAC without shock-proof protection cover
D II

25

1

6

685.1-L

K207055

D III

63

4

16

686.4-L

V215597

Volts	

: 500VAC

I.R.	

: 75kA I.R. AC

F

described.

gL-gG: 	 : Performance 	
	

characteristic

Snap-on fastening, 500 VAC with shock-proof protection cover
D II

25

1

6

685.11-L

D211511

D III

63

4

16

686.41-L

C216110

10

Approvals:
•• Meet IEC, VDE Standards: IEC
269-3, 3A VDE 0636

D Type DIAZED Fuse Bases, Screw-in
Size

Rated Current

Pole

•• Approved by Lloyds Register of

Max Cross

Catalog

Reference

Standard

Sect. mm²

Number

Number

Pack/Ctn
15

Shipping and Bureau Veritas

Screw in 500 VAC without shock-proof protection cover
D II

25

1

6

81.1-L

K218670

D III

63

4

16

72.4-L

H212021

Screw in 500 VAC with shock-proof protection cover
D II

25

1

6

81.11-L

Z219189

D III

63

4

16

72.41-L

A212543

10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

F11

D Type (DIAZED)
D Type DIAZED Fast Acting Fuses, 500VAC
Size

NDZ

D II

D III

Catalog Number

Reference Number

Gauge Color

2

Rated Current

594.002-L

C222918

PINK

4

594.004-L

L200708

BROWN

6

594.006-L

A201250

GREEN

10

594.01-L

L201766

RED

16

594.016-L

D207049

GRAY

20

594.02-L

B211509

BLUE

25

594.025-L

Y212541

YELLOW

2

597.002-L

E213559

PINK

4

597.004-L

D214064

BROWN

6

597.006-L

L214577

GREEN

10

597.01-L

S215089

RED

16

597.016-L

A216108

GRAY

20

597.02-L

J217128

BLUE

25

597.025-L

P217639

YELLOW

35

598.035-L

J218669

BLACK

50

598.05-L

J222165

WHITE

63

598.063-L

M200709

COPPER

Standard Pack/Ctn.

25

D Type DIAZED gG Fuses, 500VAC
Size

NDZ

D II

D III

D IV

DV

F12

Catalog Number

Reference Number

Gauge Color

2

Rated Current

594.0027-L

W212539

PINK

4

594.0047-L

G213055

BROWN

6

594.0067-L

C213557

GREEN

10

594.0107-L

B214062

RED

16

594.0167-L

J214575

GRAY

20

594.0207-L

Q215087

BLUE

25

594.0257-L

Q215593

YELLOW

2

597.0027-L

Z219718

PINK

4

597.0047-L

G222163

BROWN

6

597.0067-L

B222917

GREEN

10

597.0107-L

K200707

RED

16

597.0167-L

K201765

GRAY

20

597.0207-L

A211508

BLUE

25

597.0257-L

X212540

YELLOW

35

598.0357-L

C214063

BLACK

50

598.0507-L

K214576

WHITE

63

598.0637-L

R215088

COPPER

80

595.0807-L

V216609

SILVER

100

595.1007-L

M217637

RED

125

596.1257-L

V218150

YELLOW

160

596.1607-L

G218667

COPPER

200

596.2007-L

W219186

BLUE

Standard Pack/Ctn.

25

10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

D Type (DIAZED)
D Type DIAZED Screw Caps
Size

Rated Current

Cap Thread

Catalog No.

Reference No.

Standard Pack/Ctn.

Porcelain with test hole
D II

25

E 27

690.0002-L

E218619

D III

63

E 33

691.0002-L

B213004

20

Porcelain without test hole
NDZ

25

E 16

589-L

Z216613

D II

25

E 27

690-L

Z218108

50

D III

63

E 33

691-L

F211973

D IV

100

R1 1/4

592-L

Y216060

10
20

20

Plastic with test hole
D II

25

E 27

2071-L

L201720

D II

63

E 33

2072-L

E214019

Size

Rated Current
2

NDZ

Gauge Color

Catalog No.

Reference No.

pink

1655.002-L

B212544

4

brown

1655.004-L

M213060

6

green

1655.006-L

H213562

10

red

1655.010-L

G214067

16

gray

1655.016-L

P214580

Standard Pack/Ctn.

F

D Type DIAZED Gauge Pieces

50

D Type DIAZED Screw Gauge Pieces
Size

Rated Current
2

D II

D III

Gauge Color

Catalog No.

Reference No.

pink

1657.002-L

A219190

4

brown

1657.004-L

D219722

6

green

1657.006-L

L222167

10

red

1657.010-L

F222921

16

gray

1657.016-L

P200711

20

blue

1657.020-L

D201253

25

yellow

1657.025-L

P201769

35

black

1658.035-L

C207071

50

white

1658.050-L

E211512

63

copper

1658.063-L

J212022

Standard Pack/Ctn.

25

D Type DIAZED Gauge Rings
Size

D II

D III

Gauge Color

Catalog No.

Reference No.

2

Rated Current

pink

1652.002-L

W215092

4

brown

1652.004-L

W215598

6

green

1652.006-L

D216111

10

red

1652.010-L

A216614

16

gray

1652.016-L

M217131

20

blue

1652.020-L

S217642

25

yellow

1652.025-L

A218155

2

pink

1653.002-L

M218672

4

brown

1653.004-L

E219723

6

green

1653.006-L

M222168

10

red

1653.010-L

G222922

16

gray

1653.016-L

Q200712

20

blue

1653.020-L

E201254

25

yellow

1653.025-L

Q201770

35

black

1653.035-L

L207079

50

white

1653.050-L

F211513

Standard Pack/Ctn.

50

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

F13

D Type (DIAZED) Accessories
D Type DIAZED Accessories
Key for D gauge pieces
Size

Catalog Number

Reference Number

Standard Pack/Ctn.

D II, D III

1657.993-L

E216112

10

D II (40mm width)

685.7-L*

H214068

D III (50mm width)

686.7-L*

X215093

D II (45mm width)

685.709-L

Q214581

D III (54mm width)

686.709-L

X215599

D II

181.9-L

K222120

D III

182.9-L

A222870

581-L

C212545

D II Supply boards¹

2071.8-L

B216615

D II Industry²

2071.81-L

N217132

D III Supply boards¹

2072.8-L

T217643

D III Industry²

2072.81-L

B218156

D Cover
Single pole

30

*Standard version

D Touch protection rings
Plastic
50

D Adapter fittings
for D II fuses in D III bases
D II / D III

50

D Locking caps

10

¹ black top, red screw pitch
² red top, black screw pitch

F14

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

gl-gG, aM NH Dimension Knife-Blade Fuse-Links
NH Dimension Knife-Blade fuse-links, fuse bases, and
accessories
Mersen NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts
AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator
or striker and can accept a microswitch for remote signaling. They all have silverplated knife blades and ceramic bodies. Accessories include 1, 2, 3 or 4-pole bases,
barriers, shields, terminals, microswitch, etc.

gI-gG

gI-gG

Full Range Protection

Full Range Protection
Fuse-links with Striker

•• 500 and 690 Volt ratings - 2A
through 800A
•• All ratings include indicator
•• All equipped for

•• Sizes 0, 1, 2, 3
•• 500 and 690 Volt ratings - 32A
through 630A
•• All ratings include striker

microswitch mounting

Standards:

F

•• Sizes 000, 00, 0, 1, 2, 3, 4, 4a

•• DIN 57636		
•• NFC 63210-63211	
•• IEC 269-1-2-2A	
•• UNE 21103	
•• VDE 0636-2-1, 2-2
•• DIN 43620

aM

aM

Short Circuit Protection
•• • Sizes 000, 00, 0, 1, 2, 3

Short Circuit Protection
Fuse-links with Striker

•• • 400, 500 and 690 Volt ratings -

•• Sizes 0, 1, 2, 3

2A through 800A
•• • All ratings include indicator
•• • All equipped for
microswitch mounting

•• 500 and 690 Volt ratings - 2A
through 630A
•• All ratings include striker
•• Certification 		

Approvals:
•• Lloyd’s Register of Shipping
Bureau Veritas

DIN 57636		
VDE 60269		
NFC 63210, 63211	
IEC 269-1, 2, 2A	
UNE 21103
•• Approved by Lloyds Register of
Shipping and Bureau Veritas

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

F15

gl-gG NH Dimension Knife-Blade Fuse-Links
Catalog Numbers, Ratings – gl-gG
Size

000

00

0

Rated
Current (A)

Catalog Number

Interrupt Rating (A)

Std.
Pack

2

1C613

3

4

1C619

3

6

1C623

3

10

1C631

3

16

1C635

3

20

1C637

25

690V

1C639

3
80,000

3

32

1C643

3

35

1C645

3

40

1C647

3

50

1C651

3

63

1C655

3

80

1C659

3

32

1C743

3

35

1C745

3

40

1C747

3

50

1C751

63

690V

1C755

80,000

3
3

80

1C759

3

100

1C763

3

125

1C765

3

6

1C023

3

10

1C031

3

16

1C035

3

20

1C037

3

25

1C039

3

32

1C043

3

35

1C045

40

690V

1C047

80,000

3
3

50

1C051

3

63

1C055

3

80

1C059

3

100

1C063

3

125

1C065

3

160

1C069

3

16

1C135

3

20

1C137

3

25

1C139

3

32

1C143

3

35

1C145

3

40

1C147

3

50
1

Rated Voltage

690V

1C151

3
80,000

63

1C155

80

1C159

3

100

1C163

3

125

1C165

3

160

1C169

3

200

1C171

3

224

1B173

3

1B175

3

250

500V

3

Table continued on next page.

F16

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

gl-gG NH Dimension Knife-Blade Fuse-Links
Catalog Numbers, Ratings – gl-gG (cont. )

2

Rated
Current (A)

Rated Voltage

Catalog Number

Interrupt Rating (A)

Std.
Pack

32

1C243

3

35

1C245

3

40

1C247

3

50

1C251

3

63

1C255

3

80

1C259

3

100

1C263
690V

125

3
80,000

1C265

3

160

1C269

3

200

1C271

3

224

1C273

3

250

1C275

3

300

1C277

3

315

1C279

3

355

1C281

3

250

1C375

F

Size

1

3

4

4a

300

1C377

315

1C379

690V

355

1
1

80,000

1C381

1

400

1C383

1

425

1C385

1

500

1C387

1

400

8004 400765-L

1

500

8004 500765-L

690V

630

1

80,000

8004 630765-L

1

800

8004 800765-L

1

400

8014 400765-L

1

500

8014 500765-L

690V

640
800

1

80,000

8014 630765-L

1

8014 800765-L

1

Dimensions (mm)
Size

Rated
Current (A)

a1

a2

a3

a4

b

c1

e1

e2

e4

h

NH 690 V gG with voltage-conducting grip lug
SIZE 000

2-35A

79

53,8

45

49

15

35,8

40

20

6

47,8

SIZE 00

40-100A

79

53,8

45

49

15

35,8

48

30

6

47,8

SIZE 1

16-160A

135

75

64

68

20

40

44

30

6

52

SIZE 1

200A

135

75

64

68

20

40

47

39

6

52

SIZE 2

35-100A

150

75

64

68

26

48

44

30

6

60

SIZE 2

125-315A

150

75

64

68

26

60

47

39

6

72

SIZE 3

250/300A

150

75

64

68

26

60

47

39

6

72

SIZE 3

315-425A

150

75

64

68

33

60

58

51

6

72

SIZE 3

500A

150

75

64

68

33

60

70

64

6

72

SIZE 4

400-800A

200

85

64

68

33

85

104

89

8

SIZE 4a

400-800A

200

85

86

90

33

85

104

89

97
6

97

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

F17

aM NH Dimension Knife-Blade Fuse-Links
Catalog Numbers, Ratings – aM
Size

000

00

0

1

Rated Current (A)

Rated Voltage

Catalog Number

Interrupt Rating (A)

Std. Pack

2

2C613

3

4

2C619

3

6

2C623

3

10

2C631

3

16

2C635

3

20

2C637

690V

25

2C639

80,000

3
3

32

2C643

3

35

2C645

3

40

2C647

3

50

2C651

3

63

2C655

3

50

2C751

3

63

2C755
690V

80

2C759

3
80,000

3

100

2C763

3

125

2C765

3

6

2C023

3

10

2C031

3

16

2C035

3

20

2C037

3

25

2C039

3

32

2C043

3

35

2C045

690V

40

2C047

80,000

3
3

50

2C051

3

63

2C055

3

80

2C059

3

100

2C063

3

125

2C065

3

160

2C069

3

16

2C135

3

20

2C137

3

25

2C139

3

32

2C143
690V

35

2C145

3
80,000

3

40

2C147

3

50

2C151

3

63

2C155

3

80

2C159

3

Microswitch – Sizes 000 to 3
Catalog Number

Ref. Number

Std. Pkg.

MS4L2-5B6+PRES*

F210156

3

MS4L2-5B2+PRES**

G210157

3

*6.3 mm clips. **2.8mm clips

F18

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

aM NH Dimension Knife-Blade Fuse-Links
Catalog Numbers, Ratings – aM

1

Rated Current (A)

Rated Voltage

Std. Pack
3

125

2C165

3

160

2C169

200

2C171

224

2C173

3

250

2C175

3

2C245

3

40

2C247

3

50

2C251

3

63

2C255

3

80

2C259

3

100

2C263

3

125

2C265

160

2C269

200

2C271

3

224

2C273

3

250

2C275

3

315

2C279

3

355

2C281

3

400

2C283

3

2C375

1

300

2C377

1

315

2C379

1

355

2C381

1

400

2C383

425

2C385

1

450

2C386

1

500

2CC387

1
1

690V

250

3

Interrupt Rating (A)

2C163

35

2

Catalog Number

100

690V

630

500V

2B389

800

400V

2A391

3

80,000

3

3
80,000

3

80,000

F

Size

1

120,000

1

Dimensions (mm)
Size

Rated
Current (A)

a1

a2

a3

a4

b

c1

e1

e2

e4

h

NH 690 V aM with voltage-conducting grip lug
SIZE 000

2-35A

79

53,8

45

49

15

35,8

40

20

6

47,8

SIZE 00

40-100A

79

53,8

45

49

15

35,8

48

30

6

47,8

SIZE 1

16-160A

135

75

64

68

20

40

44

30

6

52

SIZE 1

200A

135

75

64

68

20

40

47

39

6

52

SIZE 2

35-100A

150

75

64

68

26

48

44

30

6

60

SIZE 2

125-315A

150

75

64

68

26

60

47

39

6

72

SIZE 3

250/300A

150

75

64

68

26

60

47

39

6

72

SIZE 3

315-425A

150

75

64

68

33

60

58

51

6

72

SIZE 3

500A

150

75

64

68

33

60

70

64

6

72

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

F19

Class C Canadian Fuses
Class C fuses
Mersen Class C fuses have British standard (BS88) dimensions and are exact
replacements for the British fuses and older HRCII-C fuses. Class C fuses
are not dimensionally or electrically interchangeable with other North American
fuses. They feature ceramic bodies and bolt-in mounting. They are for short-circuit
protection only, in motor controllers, for example, where overload protection is
provided by an overload relay.
* Ceramic version available upon request

Highlights:

Applications:

•• BS88 dimensions

•• Short circuit and back-up

•• Fast-acting

protection of motor controllers
and components

Ratings:
Volts	

: 600VAC

	: 460VDC

Catalog Numbers (amps)
FES2

FES80

FESF250

FES4

FES100

FESF300

FES6

FES125

FESF350

FES10

FES150

FESF400

FES15

FES200

FESC250

FES20

FESC80

FESC300

FES25

FESC100

FESC350

FES30

FESC125

FESC400

FES40

FESC150

FES50
FES60

FESC200

	

: 450VDC

	

: 350VDC

Amps	 : 2 to 600A
I.R.	

: 200kA I.R. AC (2-600A)

	

: 40kA I.R. DC

	460VDC:
	

FES (2-60A)

	

FESF (250-400A)

	

FESC (250-400A)

FESC450

	

450VDC:

FESC500

	

FESC (450-600A)

FESC600

	
	350VDC:
	

FES (80-100A)

	

FESC (80-200A)

Approvals:
•• CSA Certified HRCII-MISC
IEC 269-2-1

F20

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Class C Canadian Fuses
Class C Dimensions Inches (mm)
FES 2-30
FES 40-60
FES 80-100
FES 125-200
FESC 80-100
FESC 125-200
FESF 250-400
FESC 250-400
FESC 450-600

A

B

D

E

F

G

H

K

2.06

0.81

3.31

0.35

0.06

2.83

0.20

0.84

(52.3)

(20.6)

(84.1)

(8.9)

(1.6)

(71.9)

(5.2)

(21.3)

2.19

1.06

3.44

0.50

0.06

2.77

0.20

1.07

(55.6)

(26.9)

(87.4)

(12.7)

(1.6)

(70.4)

(5.2)

(27.2)

2.69

1.34

4.31

0.75

0.13

3.64

0.34

1.43

(68.3)

34.0

(109.5)

19.1

3.2

(92.5)

(8.7)

(36.3)

2.69

1.58

4.31

0.75

0.13

3.64

0.34

1.69

(8.7)

(42.9)

(68.3)

(40.1)

(109.5)

(19.1)

(3.2)

(92.5)

2.44

1.34

5.31

0.75

0.13

4.28

(61.9)

(33.9)

(134.9)

(19.1)

(3.2)

(108.7)

2.44

1.59

5.31

0.75

0.13

4.28

(61.9)

(40.3)

(134.9)

(19.1)

(3.2)

(108.7)

3.00

2.00

5.38

1.00

0.25

4.25

0.41

(76.2)

(50.8)

(136.7)

(25.4)

(6.4)

(108.0)

(10.4)

3.00

2.00

8.25

1.00

0.25

5.16

(76.2)

(50.8)

(209.6)

(25.4)

(6.4)

(131.0)

3.00

2.88

8.25

1.00

0.38

5.06

(76.2)

(73.0)

(209.6)

(25.4)

(9.5)

(128.6)

F

Catalog No.

Class C Dimensions Inches (mm)
FES2-30

FESC80-100

FES40-60

FESC125-200

FES80-100

FESF250-400

FES125-200

FESC250-400
FESC450-600
D
F
A
G

B
E

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

F21

Class CA & CB CN/CNS Canadian Fuses
Class CA and CB fuses
Mersen Canadian Class CA and CB fuses are bolt-in type, interchangeable with older
Canadian Form I/HRCI fuses for exact replacement. They are not interchangeable
with other North American fuses. CA and CB fuses are full-range, current-limiting
fuses with a high interrupting rating.

Class CA – Catalog Numbers & Dimensions
Ampere

Catalog

Rating

Number

1

C1N

3

C3N

6

C6N

10

C10N

15

C15N

20

C20N

Dimensions in mm
A

D

E

F

H

K

62

13.9

0.8

11.1

4.7

36.5

L

44.5

M

14.3

Ratings:
Volts	

: 600VAC

Amps	 : 1 to 30A
I.R.	

: 200kA I.R.

Class CB – Catalog Numbers & Dimensions
Ampere

Catalog

Rating

Number

1

CNS1

3

CNS3

6

CNS6

10

CMS10

15

CNS15

20

CNS20

25

CNS25

30

CNS30

Dimensions in mm
A

D

E

F

K

M

Approvals:
•• CSA Certified to Standard
C22.2, No. 248.3

62

14.5

0.8

11.0

35.5

11.65

Call for technical information

F22

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

NIT & NS HRCII/Canadian Fuses
Canadian HRCII fuses
The Mersen Canadian NIT fuses series has offset contacts with British standard
(BS88) dimensions. The NS series has diagonally offset contacts with British
standard dimensions. Neither fuse is dimensionally interchangeable with other North
American fuses. They are for short-circuit protection only, in motor controllers, for
example, where overload protection is provided by an overload relay.

Highlights:

Applications:

•• BS88 dimensions

•• Motor circuits

NIT – Catalog Numbers & Dimensions
Catalog

Rating

Number

2

NIT2

4

NIT4

6

NIT6

10

NIT10

16

NIT16

20

NIT20

Dimensions in mm
A

B

D

E

F

G

H

K

Ratings:
36.5

14.1

55.6

11.1

0.80

44.5

4.70

14.3

F

Ampere

NIT
Volts	

: 550VAC

	

: 250VDC

Amps	 : AC - 2 to 20A
	

: DC - 2 to 20A

I.R.	

: 80kA I.R. AC

	

: 40kA I.R. DC

NS
Volts	

: 440VAC

	

: 250VDC

Amps	 : AC - 2 to 32A

NS – Catalog Numbers & Dimensions
Ampere

Catalog

Rating

Number

2

NS2

4

NS4

6

NS6

10

NS10

16

NS16

20

NS20

25

NS25

32

NS32

Dimensions in mm
A

B

D

E

F

	

: DC - 2 to 32A

I.R.	

: 80kA I.R. AC

	

: 40kA I.R. DC

N

Approvals:
35.5

14.5

62.0

11.0

0.80

3.60

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

•• HRCII-MISC
•• IEC 269-2-1

www.barr-thorp.com

F23

Class H NRN/NRS/Canadian Fuses
NRN & NRS non-time delay fuses
Mersen NRN (250V) and NRS (600V) fuses are standard non-time delay fuses, with a
10kA short circuit rating. 250 Volt NRN15 through NRN60 fuses are certified as Type
“P” fuses, satisfying the Canadian Electrical Code for low melting-point non-time delay
fuses. Also qualifying for Type “P” are OTN15 through OTN60, which are Class K-5
fuses with a 50kA short circuit rating (found in the OT/OTS section of this catalog).

250V NRN Fuses – Dimensions
Ampere Rating

Dimensions - Inches (mm)
A

B

1-30

2.00
(50.8)

0.56
(14.2)

C

D

E
0.50
(12.7)

35-60

3.00
(76.2)

0.81
(20.6)

0.63
(16.0)

70-100

5.88
(149)

1.06
(26.9)

0.13
(3.18)

0.75
(19.1)

1.00
(25.4)

110-200

7.13
(181)

1.63
(41.4)

0.19
(4.76)

1.13
(28.7)

1.38
(35.1)

225-400

8.63
(219)

2.13
(54.1)

0.25
(6.35)

1.63
(41.4)

1.88
(47.8)

450-600

10.4
(264)

2.63
(66.8)

0.25
(6.35)

2.00
(50.8)

2.25
(57.2)

D

E

600V NRS Fuses – Dimensions
Ampere Rating

Dimensions - Inches (mm)
A

B

1-30

5.00
(127)

0.81
(20.6)

C

0.63
(16.0)

35-60

5.50
(139)

1.06
(26.9)

0.63
(16.0)

70-100

7.88
(200)

1.38
(35.1)

0.13
(3.18)

0.75
(19.1)

1.00
(25.4)

110-200

9.63
(244)

1.88
(47.8)

0.19
(4.76)

1.13
(28.7)

1.38
(35.1)

225-400

11.6
(295)

2.63
(66.8)

0.25
(6.35)

1.63
(41.4)

1.88
(47.8)

450-600

13.4
(340)

3.13
(79.5)

0.25
(6.35)

2.00
(50.8)

2.25
(57.2)

250V Fuse Ampere Ratings, Catalog Numbers
NRN1

NRN15*

NRN50*

NRN125

NRN350

NRN2

NRN20*

NRN60*

NRN150

NRN400

NRN3

NRN25*

NRN70

NRN175

NRN450

NRN4

NRN30*

NRN80

NRN200

NRN500

NRN5

NRN35*

NRN90

NRN250

NRN600

NRN6

NRN40*

NRN100

NRN250

NRN10

NRN45*

NRN110

NRN300

* CSA Type “P”

600V Fuse Ampere Ratings, Catalog Numbers

F24

NRS1

NRS15

NRS50

NRS125

NRS350

NRS2

NRS20

NRS60

NRS150

NRS400

NRS3

NRS25

NRS70

NRS175

NRS450

NRS4

NRS30

NRS80

NRS200

NRS500

NRS5

NRS35

NRS90

NRS250

NRS600

NRS6

NRS40

NRS100

NRS250

NRS10

NRS45

NRS110

NRS300

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Class H CRN/CRS/Canadian Fuses
CRN & CRS time delay fuses
Mersen CRN and CRS fuses are standard fuses, Type “D”, with 10kA short circuit
rating. Type “D” fuses satisfy the Canadian Electrical Code requirement for low meltingpoint fuses.

250V CRN Fuses – Dimensions
Dimensions - Inches (mm)
A

B

15-30

2.00
(50.8)

0.56
(14.2)

C

D

E
0.50
(12.7)

35-60

3.00
(76.2)

0.81
(20.6)

0.63
(16.0)

70-100

5.88
(149)

1.06
(26.9)

0.13
(3.18)

0.75
(19.1)

1.00
(25.4)

110-200

7.13
(181)

1.63
(41.4)

0.19
(4.76)

1.13
(28.7)

1.38
(35.1)

225-400

8.63
(219)

2.13
(54.1)

0.25
(6.35)

1.63
(41.4)

1.88
(47.8)

450-600

10.4
(264)

2.63
(66.8)

0.25
(6.35)

2.00
(50.8)

2.25
(57.2)

600V CRS Fuses – Dimensions
Ampere Rating

D

B

15-30

5.00
(127)

0.81
(20.6)

0.63
(16.0)

35-60

5.50
(139)

1.06
(26.9)

0.63
(16.0)

70-100

7.88
(200)

1.38
(35.1)

0.13
(3.18)

0.75
(19.1)

1.00
(25.4)

110-200

9.63
(244)

1.88
(47.8)

0.19
(4.76)

1.13
(28.7)

1.38
(35.1)

225-400

11.6
(295)

2.63
(66.8)

0.25
(6.35)

1.63
(41.4)

1.88
(47.8)

450-600

13.4
(340)

3.13
(79.5)

0.25
(6.35)

2.00
(50.8)

2.25
(57.2)

E

250V Fuse Ampere Ratings, Catalog Numbers*
CRN60

CRN200

CRN17-1/2

CRN70

CRN225

CRN20

CRN80

CRN250

CRN25

CRN90

CRN300

CRN30

CRN100

CRN350

CRN35

CRN110

CRN400

CRN40

CRN125

CRN450

CRN45

CRN150

CRN500

CRN50

CRN175

CRN600

: 250VAC

Amps	 : 15 to 600A

A

CRN15

CRN
Volts	

Dimensions - Inches (mm)
C

Ratings:

F

Ampere Rating

I.R.	

: 10kA I.R. AC

CRS
Volts	

: 600VAC

Amps	 : 15 to 600A
I.R.	

: 10kA I.R. AC

Approvals:
•• CSA Certified Type “D”

* For 1/10 - 12A ratings use Tri-onic TR-R.

600V Fuse Ampere Ratings, Catalog Numbers**
CRS15
CRS17-1/2
CRS20
CRS25
CRS30
CRS35
CRS40
CRS45
CRS50

CRS60
CRS70
CRS80
CRS90
CRS100
CRS110
CRS125
CRS150
CRS175

CRS200
CRS225
CRS250
CRS300
CRS350
CRS400
CRS450
CRS500
CRS600

** For 1/10 - 12 ratings use Tri-onic TRS-R.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

F25

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Special Purpose
A world of circuit protection under one roof.

Your problem:
Parallel cables
from your main
transformer.
The welding

G

Special Purpose

• CP 600V Cable Protectors................ G2

in the machine

• 2CL 250V Cable Protectors............. G10

shop. Need a

• A60C Capacitor Fuses.................... G11

fuse designed

• A4BX Welder Protectors................. G12

specifically to

• A2Y & A6Y Form 600 Fuses............ G13

protect your solar power installation? Applications as varied and
specialized as telecommunications systems, forklifts, and DC-

• Telecommunication Fuses............... G15

powered equipment . . . If your plant is like most, it’s full of highly

• Forklift Truck Fuses......................... G18

specialized circuit protecting applications. Still, as specialized as

• DC Rated Fuses.............................. G20

the installations sometimes are, they have in common the need
for a high performance, failsafe solution.

• Photovoltaic Fuses.......................... G38

Our solution: No matter how specialized your application is,
Mersen brings its broad expertise and numerous resources to
bear on it. The result is a line of Special Purpose Fuses that
unfailingly perform to application-specific requirements. Whether
you’re specifying our Helio Protection fuses, Cable Protectors,
Welder Protectors, and Telecommunications fuses — or replacing
our Form 600 fuses, or Forklift Truck fuses.
Want more information fast? For more technical or applicationspecific information, please call our special purpose products
experts, at 978-462-6662; 416-252-9371 in Canada; or visit our
website at us-ferrazshawmut.mersen.com.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G

station down

CP 600V Cable Protectors
Cable Protectors
Mersen CP Cable Protectors are special purpose limiters which are crimped or bolted
to cables or terminals to clear and isolate faults quickly, increasing the reliability
of service entrance and distribution runs. CP Cable Protectors have a 200,000A
interrupting rating, yet will carry low cable overloads which are handled by standard
protective devices. Cable protectors are rated in terms of cable size and material
(Al or Cu). Heavier duty CPH cable protectors are available on special order. Heat
shrinkable (HS) tubing can be specified for field installation. TI blown fuse trigger
indicators may be available upon request. Refer to the application information section
for more information.

Features/Benefits:

Description
Termination

Copper

Aluminum

2

CP2C1

-

1/0

CP1/0C1

-

2/0

CP2/0C1

-

4/0

CP4/0C1

CP4/0A1

Cable

250kcmil

CP250C1

CP250A1

Sizes #2 to 1000kcmil

to

350kcmil

CP350C1

CP350A1

aluminum or copper

Cable

400kcmil

CP400C1

-

500kcmil

CP500C1

CP500A1

600kcmil

CP600C1

CP600A1

750kcmil

CP750C1

CP750A1

1000kcmil

CP1000C1

-

2

CP2C3

-

1/0

CP1/0C3

-

2/0

CP2/0C3

-

4/0

CP4/0C3

CP4/0A3

Cable

250kcmil

CP250C3

CP250A3

to

350kcmil

CP350C3

CP350A3

Offset Bus

400kcmil

CP400C3

-

500kcmil

CP500C3

CP500A3

600kcmil

CP600C3

CP600A3

750kcmil

CP750C3

CP750A3

1000kcmil

CP1000C3

-

2/0

CP2/0C5

CP2/0C5

4/0

CP4/0C5

CP4/0C5

Straight Bus

250kcmil

CP250C5

CP250C5

to

350kcmil

CP350C5

CP350C5

Offset Bus

500kcmil

CP500C5

CP500C5

C

600kcmil

CP600C5

CP600C5

A

750kcmil

CP750C5

CP750C5

4/0

CP4/0C6

CP4/0A6

250kcmil

CP250C6

CP250A6

350kcmil

CP350C6

CP350A6

400kcmil

CP400C6

-

500kcmil

CP500C6

CP500A6

750kcmil

CP750C6

CP750A6

4/0

CP4/0C8

CP4/0C8

Mole

250kcmil

CP250C8

CP250C8

to

350kcmil

CP350C8

CP350C8

Offset Bus

500kcmil

CP500C8

CP500C8

750kcmil

CP750C8

CP750C8

stability in harsh environments
•• Catalog number stamped
into terminal for permanent
identification

1

•• Crimp terminals for aluminum
cable include oxide inhibitor
•• Molded rubber boots or heat
shrinkable tubing available for
insulation and protection
•• Current limiting device
•• Permitted by National Electric
Code

3

Catalog Numbering System
CP
Standard Duty
Heavy Duty

500

C

3 - TI

CP
CPH

Conductor Size
Cable Material
	Copper
	Aluminum

5

Termination
HS
Heat Shrink
Trigger Indicator TI

Mole
6

to
Cable

*Please consult factory for special terminations.

8

G2

Catalog # for Cable Type
Cable Size

•• Fiberglass bodies for dimensional

Type

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Ratings:

Volts	

: 600VAC

IR	

: 200kA I.R. AC

Approvals:
•• UL listed to File E305297

www.barr-thorp.com

CP 600V Cable Protectors
Type C1 ­– Dimensions (Cable to Cable - Copper)
Dimensions - Inches (mm)

Catalog

Cable*

No.

Size

A

B

D

E

J

N

CP2C1

#2

7.12 (180)

1.44 (37)

.42 (11)

1.75 (44)

3.62 (92)

.31 (7.9)

CP1/0C1

1/0

7.12 (180)

1.44 (37)

.52 (13)

1.75 (44)

3.62 (92)

.39 (9.9)

CP2/0C1

2/0

7.12 (180)

1.44 (37)

.56 (14)

1.75 (44)

3.62 (92)

.44 (11)

CP4/0C1

4/0

7.12 (180)

1.44 (37)

.68 (17)

1.75 (44)

3.62 (92)

.55 (14)

CP250C1

250kcmil

7.38 (188)

1.44 (37)

.75 (19)

1.88 (48)

3.62 (92)

.62 (16)

CP350C1

350kcmil

7.62 (194)

1.62 (41)

.88 (22)

2.00 (51)

3.62 (92)

.71 (18)

CP400C1

400kcmil

7.62 (194)

1.62 (41)

.94 (.24)

2.00 (51)

3.62 (92)

.75 (19)

CP500C1

500kcmil

9.38 (238)

1.88 (48)

1.05 (27)

2.88 (73)

3.62 (92)

.85 (22)

CP600C1

600kcml

9.51 (242)

2.50 (64)

1.07 (27)

2.88 (73)

3.75 (95)

.94 (24)

CP750C1

750kcmil

9.51 (242)

2.50 (64)

1.32 (34)

2.88 (73)

3.75 (95)

1.06 (27)

CP1000C1

1000kcmil

10.00 (254)

3.00 (76)

1.50 (38)

3.13 (79)

3.75 (95)

1.16 (29)

Type C1

Type C3

Type C3 ­– Dimensions (Cable to Offset Bus- Copper)
Cable*

No.

Size

A

B

D

E

I

J

L

N

CP2C3

#2

8.87 (225)

1.44 (37)

1.12 (28)

1.75 (44)

3.50 (88.9)

3.62 (92)

.96 (24)

.31 (7.9)

.42 (11)

CP1/0C3

1/0

8.87 (225)

1.44 (37)

1.12 (28)

1.75 (44)

3.50 (88.9)

3.62 (92)

.96 (24)

.39 (9.9)

.52 (13)

G

Dimensions - Inches (mm)

Catalog

R

CP2/0C3

2/0

8.87 (225)

1.44 (37)

1.12 (28)

1.75 (44)

3.50 (88.9)

3.62 (92)

.96 (24)

.44 (11)

.56 (14)

CP4/0C3

4/0

8.87 (225)

1.44 (37)

1.12 (28)

1.75 (44)

3.50 (88.9)

3.62 (92)

.96 (24)

.55 (14)

.68 (17)

CP250C3

250kcmil

9.00 (229)

1.44 (37)

1.12 (28)

1.88 (48)

3.50 (88.9)

3.62 (92)

.96 (24)

.62 (16)

.75 (19)

CP350C3

350kcmil

9.12 (232)

1.62 (41)

1.12 (28)

2.00 (51)

3.50 (88.9)

3.62 (92)

.96 (24)

.71 (18)

.88 (22)

CP400C3

400kcmil

9.12 (232)

1.62 (41)

1.12 (28)

2.00 (51)

3.50 (88.9)

3.62 (92)

.96 (24)

.75 (19)

.88 (22)

CP500C3

500kcmil

10 .00 (254)

1.88 (48)

1.62 (41)

2.88 (73)

3.50 (88.9)

3.62 (92)

1.19 (30)

.85 (22)

1.05 (27)

CP600C3

600kcmil

10 .13 (257)

2.50 (64)

2.00 (51)

2.88 (73)

3.50 (88.9)

3.75 (95)

1.31 (33)

.94 (24)

1.07 (27)

CP750C3

750kcmil

10.13 (257)

2.50 (64)

2.00 (51)

2.88 (73)

3.50 (88.9)

3.75 (95)

1.31 (33)

1.06 (27)

1.32 (34)

CP1000C3

1000kcmil

10.63 (270)

3.00 (76)

2.00 (51)

3.13 (79)

3.75 (95)

3.75 (95)

1.56 (40)

1.16 (29)

1.50 (38)

Type C5 ­– Dimensions
(Straight Bus to Offset Bus - Copper)
	
Dimensions - Inches (mm)

Catalog

Cable

No.

Size

A

B

D

J

L

M

CP4/0C5

4/0

10.37 (263)

1.44 (37)

1.12 (28)

3.62 (92)

.96 (24)

1.12 (28)

CP250C5

250kcmil

10.37 (263)

1.44 (37)

1.12 (28)

3.62 (92)

.96 (24)

1.12 (28)

CP350C5

350kcmil

10.37 (263)

1.62 (41)

1.12 (28)

3.62 (92)

.96 (24)

1.12 (28)

CP400C5

400kcmil

10.37 (263)

1.62 (41)

1.12 (28)

3.62 (92)

.96 (24)

1.12 (28)

CP500C5

500kcmil

10.37 (263)

1.88 (48)

1.62 (41)

3.62 (92)

1.19 (30)

1.50 (38)

CP600C5

600kcmil

10.50 (267)

2.50 (64)

2.00 (51)

3.75 (95)

1.31 (33)

2.00 (51)

CP750C5

750kcmil

10.50 (267)

2.50 (64)

2.00 (51)

3.75 (95)

1.31 (33)

2.00 (51)

Cable Type
TYPE 1
TYPE 2
TYPE 3
TYPE 5
TYPE 6
TYPE 7
TYPE 8

Type C5
* kcmil = MCM

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G3

CP 600V Cable Protectors
Type
C6 ­– Dimensions (Mole to Cable - Copper)
	
Dimensions - Inches (mm)

Catalog

Cable*

No.

Size

A

B

E

J

M

N

P

R

CP4/0C6

4/0

7.87 (200)

1.44 (37)

1.75 (44)

3.62 (92)

2.50 (64)

.55 (14)

.52 (13)

.68 (17)

CP250C6

250kcmil

8.00 (203)

1.44 (37)

1.88 (48)

3.62 (92)

2.50 (64)

.62 (16)

.58 (14)

.75 (19)

CP350C6

350kcmil

8.12 (206)

1.62 (41)

2.00 (51)

3.62 (92)

2.50 64)

.71 (18)

.68 (17)

.88 (22)

CP500C6

500kcmil

9 .38 (238)

1.88 (48)

2.88 (73)

3.62 (92)

2.88 (73)

.85 (22)

.81 (21)

1.05 (27)

CP750C6

750kcmil

9.51 (427)

2.50 (64)

2.88 (73)

3.75 (95)

2.88 (73)

1.06 (27)

1.00 (25)

1.32 (34)

Type C6

Type C8 ­– Dimensions (Mole to Offset Bus - Copper)
Dimensions - Inches (mm)

Catalog

Cable*

No.

Size

A

B

D

J

L

M

N

CP4/0C8

4/0

9.62 (244)

1.44 (37)

1.12 (28)

3.62 (92)

.96 (24)

2.50 (64)

.52 (14)

CP250C8

250kcmil

9.62 (244)

1.44 (37)

1.12 (28)

3.62 (92)

.96 (24)

2.50 (64)

.58 (13)

CP350C8

350kcmil

9.62 (244)

1.62 (41)

1.12 (28)

3.62 (92)

.96 (24)

2.50 (64)

.68 (17)

CP500C8

500kcmil

10.00 (254) 1.88 (48)

1.62 (41)

3.62 (92)

1.19 (30)

2.88 (73)

.81 (21)

CP750C8

750kcmil

10.13 (257) 2.50 (64)

2.00 (51)

3.75 (95)

1.31 (33)

2.88 (73)

1.00 (25)

Type C8
* kcmil = MCM

G4

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

CP 600V Cable Protectors
Type A1 ­– Dimensions (Cable to Cable - Aluminum)
Catalog

Cable*

No.

Size

A

Dimensions - Inches (mm)

CP4/0A1

4/0

CP250A1

250kcmil

CP350A1

B

J

N

Q

R

13.88 353) 1.44 (37)

3.62 (92)

.55 (14)

2.50 (64)

.85 (22)

13.88 (353) 1.44 (37)

3.62 (92)

.59 (15)

2.50 (64)

.94 (24)

350kcmil

13.88 (353) 1.62 (41)

3.62 (92)

.71 (18)

2.50 (64)

1.13 (29)

CP500A1

500kcmil

15.38 (391) 1.88 (48)

3.62 (92)

.85 (22)

2.88 (73)

1.33 (34)

CP750A1

750kcmil

15.50 (394) 2.50 (64)

3.75 (95)

1.06 (27)

2.88 (73)

1.62 (41)

Typical Terminal Assembly Details

Type A1

Type A3 ­– Dimensions (Cable to Offset Bus - Aluminum)

	

Dimensions - Inches (mm)

Cable*

No.

Size

A

B

D

J

L

N

Q

R

CP4/0A3

4/0

12.25(311)

1.44 (37)

1.12 (28)

3.62 (92)

.96 (24)

.55 (14)

2.50 (64)

.85 (22)

CP250A3

250kcmil

12.25 (311) 1.44 (37)

1.12 (28)

3.62 (92)

.96 (24)

.59 (15)

2.50 (64)

.94 (24)

CP350A3

350kcmil

12.25 (311) 1.62 (41)

1.12 (28)

3.62 (92)

.96 (24)

.71 (18)

2.50 (64)

1.13 (29)

CP500A3

500kcmil

13.00 (330) 1.88 (48)

1.62 (41)

3.62 (92)

1.19 (30)

.85 (22)

2.88 (73)

1.33 (34)

CP750A3

750kcmil

13.12 (333) 2.50 (64)

2.00 (51)

3.75 (95)

1.31 (33)

1.06 (27)

2.88 (73)

1.62 (41)

G

Catalog

Type A3

Type A6 ­– Dimensions (Mole to Cable - Aluminum)
Catalog

Cable*

Dimensions - Inches (mm)

Number

Size

A

CP4/0A6

4/0

CP250A6

250kcmil

CP350A6
CP500A6
CP750A6

E

J

N

P

Q

R

Type 5 ­– Use Copper

11.25 (286) 1.44 (37)

2.50 (64)

3.62 (92)

.55 (14)

.52 (13)

2.50 (64)

.85 (22)

	

11.25 (286) 1.44 (37)

2.50 (64)

3.62 (92)

.59 (15)

.58 (14)

2.50 (64)

.94 (24)

Type 8 ­– Use Copper Cable

350kcmil

11.25 (286) 1.62 (41)

2.50 (64)

3.62 (92)

.71 (18)

.68 (17)

2.50 (64)

1.13 (29)

	

500kcmil

12.38 (314) 1.88 (48)

2.88 (73)

3.62 (92)

.85 (22)

.81 (21)

2.88 (73)

1.33 (34)

750kcmil

12.50 (318) 2.50 (64)

2.88 (73)

3.75 (95)

1.06 (27)

1.00 (25)

2.88 (73)

1.59 (41)

B

Cable Protectors Type C5
Protectors Type C8

Type A6
* kcmil = MCM
Note: Inside surface of sleeve ends is coated with oxide inhibitor and capped.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G5

CP 600V Cable Protectors
Copper Cable Protectors with Heat Shrinkable Tubing*
Type C1, Copper Cable ­– Dimensions
A

Cable

Type C3, Copper Cable ­– Dimensions
A

Cable

Catalog No. Cable Protector

Size

Inches

Catalog No. Cable Protector
(mm)

With Heat Shrinkable Tubing

Size

Inches

(mm)

With Heat Shrinkable Tubing

4/0

7.12

(180)

CP4/0C1-HS

4/0

8.87

(225)

CP4/0C3-HS

250kcmil

9.00

(229)

CP250C3-HS

250kcmil

7.38

(188)

CP250C1-HS

350kcmil

7.62

(194)

CP350C1-HS

350kcmil

9.12

(232)

CP350C3-HS

500kcmil

9.38

(238)

CP500C1-HS

500kcmil

10.00

(254)

CP500C3-HS

750kcmil

9.51

(242)

CP750C1-HS

750kcmil

10.13

(257)

CP750C3-HS

	

	

Type C5, Copper Cable ­– Dimensions

Type C6, Copper Cable ­– Dimensions

Cable
Size
4/0

A
Inches
10.37

(mm)
(263)

A

Catalog No. Cable Protector

Cable

ith Heat Shrinkable Tubing

Size

Inches

(mm)

Catalog No. Cable Protector
With Heat Shrinkable Tubing

CP4/0C5-HS

4/0

7.87

(200)

CP4/0C6-HS

250kcmil

10.37

(263)

CP250C5-HS

250kcmil

8.00

(203)

CP250C6-HS

350kcmil

10.37

(263)

CP350C5-HS

350kcmil

8.12

(206)

CP350C6-HS

500kcmil

10.37

(263)

CP500C5-HS

500kcmil

9.38

(238)

CP500C6-HS

CP750C5-HS

750kcmil

9.51

(242)

CP750C6-HS

750kcmil

10.50

(267)

	

	

Type C8, Copper Cable ­– Dimensions
A

Cable
Size

Inches

Catalog No. Cable Protector
(mm)

With Heat Shrinkable Tubing

4/0

9.62

(244)

CP4/0C8-HS

250kcmil

9.62

(244)

CP250C8-HS

350kcmil

9.62

(244)

CP350C8-HS

500kcmil

10.00

(254)

CP500C8-HS

750kcmil

10.13

(257)

CP750C8-HS

* Transparent heat shrinkable tubing is supplied separately with -HS Catalog No. Maximum curing conditions: 5 seconds at 450˚F.

G6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

CP 600V Cable Protectors
Aluminum Cable Protectors with Heat Shrinkable Tubing*
Type A3, Aluminum Cable ­– Dimensions

Type A1, Aluminum Cable ­– Dimensions
A

Cable

A

Catalog No. Cable Protector

Cable

Size

Inches

(mm)

With Heat Shrinkable Tubing

Size

Inches

(mm)

With Heat Shrinkable Tubing

4/0

13.88

(353)

CP4/0A1-HS

250kcmil

12.25

(311)

CP250A3-HS

250kcmil

13.88

(353)

CP250A1-HS

350kcmil

12.25

(311)

CP350A3-HS

Catalog No. Cable Protector

350kcmil

13.88

(353)

CP350A1-HS

4/0

12.25

(311)

CP4/0A3-HS

500kcmil

15.38

(391)

CP500A1-HS

500kcmil

13.00

(330)

CP500A3-HS

750kcmil

15.50

(394)

CP750A1-HS

750kcmil

13.12

(333)

CP750A3-HS

	

Type A6, Aluminum Cable ­– Dimensions
Inches

(mm)

With Heat Shrinkable Tubing

	
Type 8 ­– Use Copper Cable Protectors Type C8 	

4/0

11.25

(286)

CP4/0A6-HS

	

250kcmil

11.25

(286)

CP250A6-HS

350kcmil

11.25

(286)

CP350A6-HS

500kcmil

12.38

(314)

CP500A6-HS

750kcmil

12.50

(318)

CP750A6-HS

Cable

Catalog No. Cable Protector

G

Type 5 ­– Use Copper Cable Protectors Type C5	

Size

A

		

*	Transparent heat shrinkable tubing is supplied separately with -HS
Catalog Numbers. Maximum curing conditions: 5 seconds at 450˚F.

Molded Rubber Insulating Sleeves**
	For

Type C1 Copper Cable Protectors ­– Dimensions

Catalog

Cable

No.

Size

4/0CCR

4/0

500CCR

	For

500kcmil

Dimensions - Inches (mm)
A

B

C

D

E

F

G

10.44

3.69

3.38

.83

1.33

1.50

2.00

(265)

(94)

(86)

(21)

(33)

(38)

(51)

14.19

3.69

5.25

1.31

1.81

1.94

2.44

(360)

(94)

(133)

(33)

(46)

(49)

(62)

Type C3 Copper Cable Protectors ­– Dimensions

Catalog

Cable

No.

Size

4/0CBR

4/0

500CBR

500kcmil

Dimensions - Inches (mm)
A

B

C

D

E

F

G

7.06

3.69

3.38

.83

1.33

1.50

2.00

(179)

(94)

(86)

(21)

(33)

(38)

(51)

8.94

3.69

5.25

1.31

1.81

1.94

2.44

(227)

(94)

(133)

(33)

(46)

(49)

(62)

**	 Molded rubber insulating sleeves are ordered by their own catalog numbers, and not as suffixes to the cable protector catalog numbers.
Neoprene coated except as noted.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G7

CP 600V Cable Protectors
Mersen Cable Protectors have standard commercial splicing sleeve dimensions. Any crimping tool suitable for standard
splicing sleeves, can be used. Follow crimping tool manufacturers instructions. Some crimping tool examples are shown
below. It is recommended to use at least 2 crimps.

Cable Protector Splicing Sleve Dimensions
Copper

Cable Size

Aluminum

(MCM or kcmil)

ID

OD

ID

OD

#2

0.31 (7.87)

0.42 (10.69)

-

-

1/0

0.39 (9.91)

0.52 (13.21)

-

-

2/0

0.44 (11.18)

0.56 (14.22)

-

-

4/0

0.55 (13.97)

0.68 (17.27)

0.54 (13.8)

0.84 (21.5)

250

0.62 (15.75)

0.75 (19.05)

0.59 (15.1)

0.94 (23.7)

350

0.71 (18.03)

0.88 (22.35)

0.71 (18.0)

1.13 (28.7)

400

0.75 (19.05)

0.94 (23.88)

-

-

500

0.82 (20.83)

1.05 (26.67)

0.84 (21. 2)

1.31 (33.3)

600

0.94 (23.88)

1.07 (27.18)

0.92 (23.4)

1.44 (36.6)

750

1.06 (26.92)

1.32 (33.53)

1.03 (26.2)

1.59 (40.4)

1000

1.16 (29.46)

1.50 (38.1)

-

-

Panduit - Copper
CT-920, CT-920CH, CT-930, CT-930CH, CT-2920

Cable Size (MCM
or kcmil)

Die

Die Color & Die No.

#2

CD-920-2

Brown P33

1/0

CD-920-1/0

Pink P42

2/0

CD-920-2/0

Black P45

4/0

CD-920-4/0

Purple P54

250

CD-920-250*

Yellow P62

350

CD-920-350

Red P71

400

CD-920-400

Blue P76

500

CD-920-500

Brown P87

600

CD-920-600

Green P94

750

CD-920-750

Black P106

* Copper Tap Connector Part Nos: HTCT250-8,
HTCT250-2, HTCT250-250
* Tap Connector Die Part No: CD-930H-250

Panduit - Aluminum
CT-920, CT-920CH, CT-930, CT-930CH, CT-2920

Cable Size (MCM
or kcmil)

Die

Die Color & Die No.

#2

CD-920-1/0

Pink P42

1/0

CD-920-3/0**

Tan P50 (Orange P50)

2/0

CD-920-4/0

Olive P54 (Purple 54)

4/0

CD-920-300

White P66

250

CD-920-350

Red P71

350

CD-920-500

Brown P87

400

CD-920-600

Green P94

500

CD-920-500A

Pink P99

600

CD-920-750

Black P106

750

-

-

** Aluminum Tap Connector Part No: HTAP2-8-L
(PANDUIT Die Color & Die No)

Note: Crimp Tools CT 2940 and CT940H may be used with adapter CD-940-DA

G8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

CP 600V Cable Protectors
Thomas & Betts - Copper
Cable Size (MCM 13642M (13400) Hydraulic Head

TBM14 (14 TON) Head

TBM15 (15 TON) Head

Head

or kcmil)

Die Cat No.

Die Code

Die Cat No.

Die Code

Die Cat No.

Die Code

Die Cat No.

Die Code

#2

11735

33

15528

33

15528

33

11402

33

1/0

11737

42

15508

42

15508

42

11334

42

2/0

11738

45

15526

45

15526

45

11405

45

4/0

11740

54

15511

54

15511

54H

11407

54H

250

11771

62

15510-CK

62

15510-CK

62

297-31669-7

62

350

11743

71H

15514-CK

71H

15514-CK

71H

11363

71

400

11744

76H

15512

76H

15512

76H

11410

76

500

11746-TB

87H

15506

87H

15506

87H

11423

87

600

11748

99H

15536-CK

94H

15536-CK

94H

11364

94

750

-

-

15515-CK

106H

15515-CK

106H

74506

106

-

-

15603

125H

11416

125

1000

Thomas & Betts - Aluminum
TBM14 Head

TBM15 Head

21940 (40 TON) Head

or kcmil)

Die Cat No.

Die Code

Die Cat No.

Die Code

Die Cat No.

Die Code

Die Cat No.

Die Code

4/0

11742

66H

15534

66H

15534

66H

11409

66

250

11744

76H

15512

76H

15512

76H

11410

76

350

11747

94H

15536-CK

94H

15536-CK

94H

11364

94

400

-

-

-

-

-

-

-

-

500

11749

106H

15515-CK

106H

15515-CK

106H

74506

106

600

11751

112H

15504

115H

15609

112H

11426

112

750

-

-

-

-

15602

140H

11418

140

Burndy - Copper

G

Cable Size (MCM 13642M (13400) Hydraulic Head

Burndy - Aluminum
Burndy Hypress and Die Set

Cable Size (MCM

Cable Size

or kcmil)

Y35

Y39

Y750

Y46*

#2

U2CRT

U2CRT

U2CRT

U2CRT

1/0

U25RT

U25RT

U25RT

U25RT

2/0

U26RT

U26RT

U26RT

4/0

U28RT

U28RT

U28RT

250

U29RT

U29RT

350

U31RT

400
500

(MCM or

Burndy Hypress and Die Set
Y35

Y39

#2

-

-

1/0

-

-

U26RT

2/0

U26ART

U26ART

U28RT

4/0

U28ART

U28ART

U29RT

U29RT

250

U29ART

U29ART

U31RT

U31RT

U31RT

350

U31ART

U31ART

U32RT

U32RT

U32RT

U32RT

400

U32ART

U32ART

-

U34RT

U34RT

U34RT

500

-

U34ART

600

-

U36RT

U36RT

U36RT

600

-

U36ART

750

-

U39RT

U39RT

U39RT

750

-

U39ART-2

1000

-

-

-

P44RT**

1000

-

-

kcmil)

* Requires PUADP-1 Adapter

* Requires PUADP-1 Adapter

** PUADP-1 Adapter not required

** PUADP-1 Adapter not required

Note: Use Burndy Dies with Ilsco ILC-15H crimp tool by installing adapter part no ILD-PADP

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G9

2CL 250V Cable Protectors
250V Cable Protectors
Mersen 2CL Cable Protectors are special purpose limiters which are crimped or
bolted to cables or terminals to clear and isolate faults quickly, increasing the
reliability of service entrance and distribution runs. They are 250VAC current
limiting with a 200,000A interrupting rating, yet will carry low cable overloads
which are handled by standard protective devices. These cable protectors are
rated for both copper and aluminum cabling per their corresponding cable size.

Features/Benefits:
•• Fiberglass bodies for dimensional stability in harsh environments
•• Catalog number stamped into terminal for permanent identification
•• 250VAC Rated
•• Shorter in length, smaller dimensions than standard 600VAC rated cable
limiters

Ratings:

Catalog Numbers

	

Type

BB

BF

CC

CF

G10

Termination

Cable Size

Catalog No.

1

2CL1BB

2

2CL2BB

3

2CL3BB

4

2CL4BB

1/0

2CL10BB

2/0

2CL20BB

3/0

2CL30BB

4/0

2CL40BB

250

2CL250BB

350

2CL350BB

500

2CL500BB

1

2CL1BF

2

2CL2BF

3

2CL3BF

4

2CL4BF

1/0

2CL10BF

2/0

2CL20BF

3/0

2CL30BF

4/0

2CL40BF

250

2CL250BF

350

2CL350BF

500

2CL500BF

1/0

2CL10CC

2/0

2CL20CC

4/0

2CL40CC

250

2CL250CC

350

2CL350CC

500

2CL500CC

1/0

2CL10CF

2/0

2CL20CF

Cable to Offset

4/0

2CL40CF

Bus

250

2CL250CF

350

2CL350CF

500

2CL500CF

Blade to Blade

Blade to Offset
Bus

Cable to Cable

Sizes 1 to 500 kcmil

Catalog Numbering System
2CL

500 B

B

250VAC Cable Limiter
Conductor Size

copper and aluminum
	
Volts	

: 250VAC

IR	

: 200kA I.R. AC

Termination Type 1st End
Termination Type 2nd End
*Please consult factory for special terminations.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Approvals:
•• Self Certified

www.barr-thorp.com

A60C Low Voltage Capacitor Fuses
600V Low Voltage Capacitor Fuses
Mersen low voltage capacitor fuses provide advanced safety for power correction and
harmonic filtering equipment. A capacitor fuse isolates a shorted capacitor before it
can damage surrounding equipment or personnel. Typical capacitor failures occur
when the internal dielectric can no longer withstand the applied voltage, resulting
in a low impedance current path and generating excessive heat and pressure that
can cause violent case rupture. Mersen low voltage capacitor fuses will isolate the
shorted capacitor before case rupture occurs while routinely withstanding inrush
current at startup.

•• High interrupting rating

Catalog Numbers (amps)
Without indicator

With indicator

A60C10-121

-

A60C15-121

-

capability

A60C20-121

-

•• Direct mount

A60C25-121

A60C25-121TI

•• Optional blown fuse indication

A60C30-121

-

A60C35-121

A60C35-121TI

A60C40-121

A60C40-121TI

A60C50-121

A60C50-121TI

A60C60-121

A60C60-121TI

-

A60C75-121TI

A60C80-121

A60C80-121TI

A60C100-121

A60C100-121TI

A60C125-121

A60C125-121TI

A60C150-121

A60C150-121TI

A60C175-121

A60C175-121TI

A60C200-121

A60C200-121TI

A60C225-121

A60C225-121TI

A60C250-121

A60C250-121TI

Approvals:

A60C300-121

A60C300-121TI

•• UL Recognized Component File

•• Current-limiting
•• Capacitor inrush withstand

Ratings:
Volts	

: 600VAC

Amps	 : 10 to 300A
IR	

G

Features/Benefits:

: 200kA I.R.

E60314

Dimensions

•• Tested by UL to CSA standard
C22.2 No. 248.1

A60C without Indicator

A60C with Indicator

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G11

A4BX Welder Protectors
Welder protectors
Mersen Welder Protectors are special purpose limiters used to provide isolation of
faulted welding equipment and protection for the cable drop supplying the welder.
Welder Protectors have a high thermal capacity and are less affected by high ambient
temperatures and extended weld times than similar size Class J, K, or R fuses*.
Welder Protectors should only be applied for isolation of short circuited welding
circuits. Overload protection must be provided for by other means.
*Contact factory for Class L sizes and ratings.

Catalog
Numbers (amps)
	
Class K Dimension

Class J Dimension

A4BX100-150

-

A4BX125-150

-

A4BX150-150

-

A4BX200-150

A4BX200-150J

A4BX225-150

A4BX225-150J

A4BX300-150

A4BX300-150J

Amps	 : 100 to 600A

A4BX400-150

A4BX400-150J

A4BX500-150

-

IR	

A4BX600-150

-

Ratings:
Volts	

: 600VAC
: 200kA I.R.

	

*For larger ratings consult factory.

A4BX (amps) - 150; Class K Dimensions
Inches

Ampere
Rating

A

B

C

D

E

F

G

H

100

7-7/8

1

1/8

23/32

2-5/8

-

-

-

125-200

9-5/8

1-1/2

3/16

1-1/8

3-7/16

-

-

-

225-400

11-5/8

2

1/4

1-5/8

4-7/16

-

-

-

500-600

13-3/8

2-1/2

1/4

2

5-5/16

-

-

-

Approvals:
•• Self Certified

A4BX
	

(amps) - 150J; Class J Dimensions

200

5-3/4

1-1/2

3/16

1-1/8

1-1/2

4-3/8

3/8

9/32

225-400

7-1/8

2

1/4

1-5/8

2-3/16

5-1/4

17/32

13/32

Class K

Class J

G12

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

A2Y/A6Y Form 600
Form 600 fuses
Mersen Form 600 fuses are the original current-limiting fuses, pre-dating all the
standards. Their 500V DC rating (through 600A) is a useful feature for special fusing
applications. Form 600 fuses provide a high degree of current limitation in AC and DC
applications. Types 1 and 3 are dimensionally interchangeable with Class H and K
fuses. Types 4 and 5 have unique rejection dimensions and are not interchangeable.

Catalog Numbers (amps)
600V

Type 1,
1-60 Amperes Class K
Dimensions

A2Y200-3

A6Y1-1

A6Y200-3

A2Y2-1

A2Y200-4

A6Y2-1

A6Y200-4

A2Y3-1

-

A6Y3-1

A6Y200-5

A2Y5-1

-

A6Y5-1

A6Y225-3

Ampere

A2Y6-1

-

A6Y6-1

A6Y225-4

Rating

A2Y8-1

-

A6Y8-1

A6Y225-5

A2Y - 1-60A

A2Y10-1

A2Y250-3

A6Y10-1

A6Y250-3

1-30

2

9/16

A2Y15-1

A2Y250-4

A6Y15-1

A6Y250-4

35-60

3

13/16

A2Y20-1

-

A6Y20-1

A6Y250-5

A6Y - 1-60A

A2Y25-1

A2Y300-3

A6Y25-1

A6Y300-3

1-30

5

13/16

A2Y30-1

A2Y300-4

A6Y30-1

A6Y300-4

35-60

5-1/2

1-1/16

A2Y35-1

-

A6Y35-1

A6Y300-5

A2Y40-1

A2Y350-3

A6Y40-1

A6Y350-3

A2Y45-1

A2Y350-4

A6Y45-1

A6Y350-4

A2Y50-1

A2Y400-3

A6Y50-1

A6Y400-3

A2Y60-1

A2Y400-4

A6Y60-1

A6Y400-4

A2Y70-3

-

A6Y70-3

A6Y400-5

A2Y70-4

A2Y450-3

A6Y70-4

A6Y450-3

A2Y70-5

A2Y450-4

-

A6Y450-4

A2Y80-3

-

A6Y80-3

A6Y450-5

A2Y80-4

A2Y500-3

A6Y80-4

A6Y500-3

A2Y90-3

A2Y500-4

A6Y90-3

A6Y500-4

A2Y90-4

A2Y500-5

-

A6Y500-5

A2Y100-3

A2Y600-3

A6Y100-3

A6Y600-3

A2Y100-4

A2Y600-4

A6Y100-4

A6Y600-4

A2Y125-3

A2Y600-5

A6Y125-3

A6Y600-5

A2Y125-4

-

A6Y125-4

A6Y650-4

-

-

A6Y125-5

A6Y800-4

A2Y150-3

-

A6Y150-3

A6Y800-5

A2Y150-4

-

A6Y150-4

A6Y1000-4

-

-

A6Y150-5

A6Y1000-5

A2Y175-3

-

A6Y175-3

A6Y1200-4

A2Y175-4

-

A6Y175-4

A6Y1200-5

-

	

Inches
A

B

Ratings:
A2Y			
Volts	 : 250VAC
	
: 500VDC
Amps	 : 1 to 600A
IR	
: 200kA I.R.AC
	
: 100kA I.R. DC
A6Y			
Volts	 : 600VAC
	
: 500VDC
Amps	 : 1 to 8A (500VAC)
	
: 10 to 1200A (600VAC)
	
: 1 to 600A (500VDC)	
IR	
: 200kA I.R. AC
	
: 100kA I.R. DC

G

250V
A2Y1-1

Approvals:
•• UL Recognized Component	
File E60314
•• DC Tested to UL248-1 (1-600A)

A6Y175-5

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G13

A2Y/A6Y Form 600
Type 3, 70-600 Amps, Class K Dimensions
Inches

Ampere Rating

A

B

C

D

E

J

250 VAC/500 VDC - A2Y (Amp) - 3
70-100

5-7/8

1

1/8

23/32

1-5/8

2-21/32

125-200

7-1/8

1-1/2

3/16

1-1/8

2-3/16

2-25/32

225-400

8-5/8

2

1/4

1-5/8

2-15/16

2-25/32

450-600

10-3/8

2-1/2

1/4

2

3-13/16

2-25/32

600 VAC/500 VDC - A6Y (Amp) - 3
70-100

7-7/8

1

1/8

23/32

2-5/8

2-21/32

110-200

9-5/8

1-1/2

3/16

1-1/8

3-7/16

2-25/32

225-400

11-5/8

2

1/4

1-5/8

4-7/16

2-25/32

450-600

13-3/8

2-1/2

1/4

2

5-5/16

2-25/32

Type 3 70-600A

Type 4, 70-600 Amps ­– Dimensions
Inches

Ampere
Rating

A

B

C

D

E

F

H

J

P

250 VAC/500 VDC - A2Y (Amp) - 4
70-100

5-7/8

1

1/8

23/32

1-5/8

4-7/8

13/64

2-21/32

1/2

125-200

7-1/8

1-1/2

3/16

1-1/8

2-3/16

5-3/4

17/64

2-25/32

11/16

225-400

8-5/8

2

1/4

1-5/8

2-15/16

6-3/4

21/64

2-25/32

15/16

450-600

10-3/8

2-1/2

1/4

2

3-13/16

8-1/8

25/64

2-25/32

1-1/8

23/32

2-5/8

6-7/8

13/64

2-21/32

1/2

600 VAC/500 VDC - A6Y (Amp) - 4
70-100

7-7/8

1

1/8

125-200

9-5/8

1-1/2

3/16

1-1/8

3-7/16

8-1/4

17/64

2-25/32

11/16

225-400

11-5/8

2

1/4

1-5/8

4-7/16

9-3/4

21/64

2-25/32

15/16

450-600

13-3/8

2-1/2

1/4

2

5-5/16

11-1/8

25/64

2-25/32

1-1/8

	

Type 4 70-600A

	

Type 4 650-1200A

Type 4, 650-1200 Amps ­– Dimensions
Inches

Ampere
Rating

A

B

D

E

F

J

K

Q

2

3-3/8

7-7/8

3-3/4

1-5/16

5/8

600 VAC only - A6Y (Amp) - 4
650-1200

10-1/2

3

Type 5, 125-600 Amps ­– Dimensions
Ampere
Rating

Inches
A

B

C

D

E

F

G

H

J

P

600 VAC/500 VDC - A6Y (Amp) - 5
125-200

10-3/4

1-1/2

3/16

1-1/8

3-7/16

8-1/4

3/4

17/64

2-25/32

11/16

225-400

13-1/4

2

1/4

1-5/8

4-7/16

9-3/4

7/8

21/64

2-25/32

15/16

450-600

15-3/16 2-1/2

1/4

2

5-5/16

11-1/8

1

25/64

2-25/32

1

Type 5 125-600A

Type 5, 650-1200 Amps ­– Dimensions
Inches

Ampere
Rating

A

B

D

E

F

J

K

Q

3-3/8

7-7/8

3-3/4

1-5/16

5/8

600 VAC only - A6Y (Amp) - 5
650-1200

G14

12-1/8

3

2

Type 5 650-1200A

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

TGL, TGN, TGS Telecommunications Fuses
Mersen Telecommunications fuses are specially designed for the protection of
telecommunications equipment which includes telephone switching equipment,
rectifiers, distribution switching panels, battery back-up modules, power supplies and
switching sub-stations. Telecom fuses are available from 1 to 800 amperes rated
at 170VDC with an interrupting rating of 100,000 amps. Telecom fuses have high
current limiting capabilities to provide a better degree of circuit protection to traditional
telecommunications equipment. These fuses consist of a blue and white label for
easy identification of their DC voltage capability.

Features/Benefits:
•• All fuses rated 170VDC, 100kA I.R.
•• Extremely current limiting
•• Blue & white labels for easy identification

Highlights:

Applications:

Ratings:

•• DC rated

•• Distribution switching panels

•• Highly current limiting

•• Battery back-up systems

•• Fast acting

•• Power supplies

•• Rejection style

•• Switching substations

TGL
Volts	
Amps	
IR	
TGN
Volts	
Amps	
IR	
TGS
Volts	
Amps	
IR	

•• Telephone switching rectifiers

Telecom
Fuse Cross Reference
	
Competitor Part No.

Mersen Part No.

TPL

TGL

TPN

TGN

TPS

TGS

Recommended Fuse Holders
	
Fuse
TGL

TGN

TGS

Ampere

1-Pole

70-250A

P243D

3-Pole

300-800A

P243G

0-30

20306R

20308R

31-60

20606R

20608R

61-100

21036R

21038R

101-200

22001R

22003R

201-400

24001R

24003R

401-600

2631R

2633R

0-70A

30656T

30658T

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

: 170VDC
: 70 to 800A 		
: 100kA I.R.

G

•• Various mounting configurations

: 170VDC
: 1 to 600A 		
: 100kA I.R.
: 170VDC
: 1 to 70A
: 100kA I.R.

Approvals:
•• UL recognized components File
E60314

www.barr-thorp.com

G15

TGL, TGN, TGS Telecommunications Fuses
TGN
Catalog Numbers (amps)

Dimensions - TGN

TGN1

TGN40

TGN175

Ampere

TGN3

TGN45

TGN200

Rating

TGN5

TGN50

TGN225

170 VDC TGN FUSES

TGN6

TGN60

TGN250

0-30

2

51

9/16

14

TGN10

TGN70

TGN300

31-60

3

76

13/16

21

TGN15

TGN80

TGN350

61-100

5-7/8

149

1-1/16

27

1/8

3

3/4

19

1

25

TGN20

TGN90

TGN400

101-200

7-1/8

181

1-9/16

40

3/16

5

3/4

19

1-3/8

35

TGN25

TGN100

TGN450

TGN30

TGN110

TGN500

TGN35

TGN150

TGN600

A
In.

B
mm

In.

C
mm

In.

D
mm

In.

E
mm

In.

mm

201-400

8-5/8

219

2-1/16

53

1/4

6

1-5/8

41

1-7/8

48

401-600

10-3/8

264

2-9/16

66

1/4

6

2

51

2-1/4

57

	

C
A
0-60A

A
61-600A

B

B

TGL
Catalog Numbers

Dimensions - TGL

Catalog No.

Ampere Rating

Catalog No.

TGL-BA

70A

TGL-BL

Ampere Rating
250A

TGL-BB

80A

TGL-CN

300A

TGL-BC

90A

TGL-CO

350A

TGL-BD

100A

TGL-CR

400A

TGL-BE

125A

TGL-CU

450A

TGL-BF

150A

TGL-CV

500A

TGL-BG

175A

TGL-CZ

600A

TGL-BH

200A

TGL-CZH

800A

TGL-BK

225A

Fig. 1 BA(70A)
– BL(250A)

Fig. 2 CN(300A)
– CZH(800A)

TGS
Catalog Numbers (amps)

G16

TGS1

TGS20

TGS2

TGS25

TGS3

TGS30

TGS5

TGS40

TGS6

TGS50

TGS10

TGS60

TGS15

TGS70

Dimensions - TGS

.88 ± .02
[22.35± .5mm]

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

ø .566± .006
[14.3± .015mm]

www.barr-thorp.com

GMS Telecommunications Fuses
GMS Series Alarm Indicating Telecommunications Fuses
Mersen GMS Series Alarm Indicating fuses are used in telecommunications
equipment or other applications. A color coded flag indicates a circuit problem which
caused the fuse to blow. Nineteen ampere ratings/colors fill every replacement need.
GMS: Alarm indicating telecommunications fuse

Features/Benefits:
•• Color coded 	
•• Body material PPS UL 94V-0	
•• Rated 125V AC, 60V DC
•• Carry 100% load - 10 minutes, min.	
•• Clear 150% load - 5 minutes, max.

Catalog
Numbers (amps)
	

	

Catalog No.

Color Code

Catalog No.

Color Code

GMS18/100

Yellow

GMS2-1/2

White-Orange

GMS2/10

Black-Red

GMS3

Blue

GMS1/4

Violet

GMS3-1/2

White-Blue

GMS1/2

Red

GMS4

White-Brown

GMS65/100

Black

GMS5

Green

GMS3/4

Brown

GMS7-1/2

Black-White

GMS1

Gray

GMS10

Red-White

GMS1-1/3

White

GMS12

Yellow-Green

GMS1-1/2

White-Yellow

GMS15

Red-Blue

GMS2

Orange

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Ratings:
Volts	

: 125VAC

	

: 60VDC

G

	

Amps	 : 180mA to 15A

www.barr-thorp.com

G17

Forklift Truck Fuses
Mersen Forklift Truck and Battery Isolator fuses are specially designed for the heavy
duty loads associated with DC battery powered equipment such as forklift trucks,
hand trucks, motorized work platforms, and other DC battery operated systems.
Rugged construction and stud mounted bolt-in design assure a long life in adverse
conditions for these fuses. This expanded line of Forklift Truck Fuses can fulfill
virtually all of your heavy duty circuit protection needs up to 125V AC or DC. The
round body ACK, ACL and ALS fuses combine higher voltage ratings and more
ampere ratings with higher interrupting ratings. The flat CNL and CNN style fuses
have a lower voltage rating but are also AC and DC, more space saving and have
visual “see-thru” indication to show when they have operated.

Features/Benefits:
•• All fuses are AC and DC rated
•• Expanded ampere ratings
•• Time-delay and general purpose types
•• Link is visible through window (CNL/CNN)

Highlights:

Applications:

•• AC/DC ratings

•• Forklift trucks

•• Embossed catalog No’s.

•• Battery hand trucks

•• Stud mounted

•• Motorized work platforms

•• Time-delay - ACK

•• Battery systems

•• General purpose - ACL,ALS

Recommended Fuse Blocks for
Forklift Truck Fuse Fuses
Fuse

Fuse Block

ACK(70-100)

P243C

ACL(70-120)

P243E

CNL

FTFH, FTFH-1

CNN

FTFH, FTFH-1

Ratings:
ACK:
Volts	
Amps	
IR	
ACL
Volts	
Amps	
IR	
	
ALS
Volts	
Amps	
IR	

CNL
Volts	
Amps	
IR	
CNN
Volts	
	
Amps	
IR	

: 125VAC / DC
: 1 to 400A 		
: 10kA I.R. AC / DC
: 125VAC / DC
: 30 to 120A 		
: 100kA I.R. AC
: 10kA I.R. DC
: 125VAC / DC
: 100 to 500A
: 10kA I.R. AC / DC

: 80VAC / DC
: 35 to 500A
: 2500kA I.R. AC / DC
: 130 VAC
: 80VDC
: 10 to 800A
: 2500kA I.R. AC / DC

Approvals:

•• UL recognized components (All
Products) File E60314

G18

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Forklift Truck Fuses
Catalog Numbers (amps)

ACK1

ALS Fuse

ACL Fuse

ACK
Fuse
	

ACK20

ACK70

ACL30

ACK160

ACL70

ALS100

ALS300
ALS350

ACK2

ACK25

ACK80

ACK175

ACL35

ACL80

ALS150

ACK3

ACK30

ACK90

ACK200

ACL40

ACL90

ALS175

ALS400

ACK5

ACK35

ACK100

ACK225

ACL50

ACL100

ALS200

ALS450

ACL60

ACL120

ALS225

ALS500

ALS250

–

ACK6

ACK40

ACK120

ACK250

ACK10

ACK50

ACK140

ACK300

ACK15

ACK60

ACK150

ACK400

CNL/CNN:
CNL

–

CNN350

–

CNL130

CNL350

CNN35

CNN150

CNN400

CNL35

CNL150

CNL400

CNN40

CNN175

CNN500

CNL40

CNL175

CNL500

CNN50

CNN200

CNN600

CNL50

CNL200

CNL600

CNN60

CNN225

CNN225

CNL60

CNL225

CNL675

CNN80

CNN250

-

CNL80

CNL250

-

CNN90

CNN275

CNN700

–

CNL275

CNL750

CNN100

CNN300

-

CNL100

CNL300

-

CNN125

CNN325

CNN800

CNL125

CNL325

-

G

CNN
CNN10

Dimensions
Catalog No.

Outline

A

B

C

D

E

F

G

Figure

In. (mm)

In. (mm)

In. (mm)

In. (mm)

In. (mm)

In. (mm)

In. (mm)

ACK 1-30

1

3.07 (77.9)

2.5 (63.5)

.56 (14.3)

.5 (12.7)

.28 (7.1)

.593 (15)

.03 (.8)

ACK 35-60

1

3.74 (95)

3 (76.2)

.81 (20.6)

.75 (19.1)

.34 (8.7)

.86 (21.8)

.047 (1.2)

ACK 70-100

1

4.46 (113.4)

3.5 (88.9)

1.06 (26.9)

1 (25.4)

.38 (9.5)

1.12 (28.5)

.06 (1.6)

ACK 120-200

1

4.72 (119.8)

3.75 (95.4)

1.06 (26.9)

1 (25.4)

.38 (9.5)

1.12 (28.5)

.06 (1.6)

ACK 225-400

1

4.71 (119.7)

3.75 (95.4)

1.06 (26.9)

1 (25.4)

.38 (9.5)

1.12 (28.5)

.06 (1.6)

ACL 30-60

1

3.07 (77.9)

2.5 (63.5)

.56 (14.3)

.5 (12.7)

.28 (7.1)

.593 (15)

.03 (.8)

ACL 70-120

1

3.49 (88.6)

2.75 (69.9)

.81 (20.6)

.75 (19.1)

.34 (8.7)

.86 (21.8)

.047 (1.2)

ALS 100-500

1

4.71 (119.7)

3.75 (95.4)

1.06 (26.9)

1 (25.4)

.38 (9.5)

1.12 (28.5)

.06 (1.6)

CNL/CNN

2

3.188 (80.9)

2.44 (61.9)

.89 (22.6)

.75 (19.0)

.34 (8.7)

––

––

Figure 1
Figure 2

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G19

440V DC Ferrule Fuses
Sizes: 14x51, 22x58, 27x60
gLB from 2 to 160 A

Dimensions

Ratings:
Volts	
Amps	
IR	
L/R	

Trip force: 4.5N (1lb) at 0 mm-2.5N (1/2lb ) at 7 mm (1/4”)

: 440VDC
: 2 to 160A 		
: 100kA I.R.
: 30mSec

Catalog Numbers, Ratings
Current
Size

Rating
IN(A)

14x51

22x58

IN(A)

Watts Loss
0.8 IN

IN

Catalog Number

Ref. No.

2

0.29

0.5

CC 4.421 CP gLB 14x51/2

E075720

6

0.74

1.3

CC 4.421 CP gLB 14x51/6

Q094084

8

1.1

1.8

CC 4.421 CP gLB 14x51/8

F075721

10

1.1

1.9

CC 4.421 CP gLB 14x51/10

G075722

12

@ 440VDC

1.2

2.0

CC 4.421 CP gLB 14x51/12

R094085

16

100 kA

1.2

2.1

CC 4.421 CP gLB 14x51/16

H075723

20

L/R = 30 ms

1.4

2.5

CC 4.421 CP gLB 14x51/20

L221132

25

1.6

2.8

CC 4.421 CP gLB 14x51/25

J075724

32

2.4

4.2

CC 4.421 CP gLB 14x51/32

S098410

40

2.9

5.0

CC 4.421 CP gLB 14x51/40

T098687

50

3.3

5.7

CC 4.421 CP gLB 14x51/50

H076620

50

3.9

6.7

CC 4.421 CP gLB 22x58/50

L076968

4.9

8.5

CC 4.421 CP gLB 22x58/63

M221133

6.2

10.8

CC 4.421 CP gLB 22x58/80

J098563

7.5

13.2

CC 4.421 CP gLB 22x58/100

K099507

22

CC 4.421 CP gLB 27x60/125

H098562

24.2

CC 4.421 CP gLB 27x60/160

M075704

63
80
100

27x60

Interrupting

@ 440VDC
100 kA
L/R = 30 ms

125

@440VDC 100 kA

12.6

160

L/R = 30 ms

13.8

Blown fuse indicator minimum trip voltage: 20 V

G20

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

660V DC Ferrule Fuses
Size: 27x60
Features/Benefits:
•• Full range D.C. operation
•• 27x60mm ceramic cylindrical body
•• Blown-fuse indicator striker

Catalog Numbers, Ratings

27 x 60

Current

Interrupting

Rating IN(A)

Rating

Watts Loss

Catalog No.

Ref. No.

0.4

CC 6,621 CP gRB 27x60/0.8

H098585

0.25

0.4

CC 6,621 CP gRB 27x60/1

J098586

0.35

0.6

CC 6,621 CP gRB 27x60/1.5

K098587

2

0.4

0.7

CC 6,621 CP gRB 27x60/2

P098591

3.15

0.6

1

CC 6,621 CP gRB 27x60/3.15

Q098592

Ratings:

4

0.6

1

CC 6,621 CP gRB 27x60/4

R098593

Volts	

5

0.7

1.1

CC 6,621 CP gRB 27x60/5

T098595

Amps	 : 0.8 to 110A

6.3

0.8

1.3

CC 6,621 CP gRB 27x60/6.3

Z098600

IR	

8

1.2

2

CC 6,621 CP gRB 27x60/8

L076301

L/R	: 15mSec

0.8 IN

IN

0.8

0.25

1
1.5

10

@ 660V DC

1.3

2.3

CC 6,621 CP gRB 27x60/10

M076302

12

50kA

1.4

2.4

CC 6,621 CP gRB 27x60/12

L075703

16

L/R = 15ms

1.9

3.3

CC 6,621 CP gRB 27x60/16

N076303

20

2.4

4.1

CC 6,621 CP gRB 27x60/20

C077006

25

2.8

4.7

CC 6,621 CP gRB 27x60/25

M075635

32

3.5

6

CC 6,621 CP gRB 27x60/32

P076304

40

4.7

8

CC 6,621 CP gRB 27x60/40

Q076305

50

4.8

8.3

CC 6,621 CP gRB 27x60/50

R076306

63

5.6

9.6

CC 6,621 CP gRB 27x60/63

P079961

80

6.4

11.2

CC 6,621 CP gRB 27x60/80

S079964

100

7.4

12.9

CC 6,621 CP gRB 27x60/100

T099400

110

7.7

13.7

CC 6,621 CP gRB 27x60/110

S076307

Blown fuse indicator minimum trip voltage: 20V

: 660VDC

G

Size (Mm)

: 50kA I.R.

Approvals:
•• UL recognized component File
E76398

Dimensions
60,3

• 27

7mm
indicator
travel
• 5mm

Indicator Trip Force: 4.5N (1lb) at 0mm-2.5N (1/2lb) at 7mm (1/4”)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G21

1000V DC Ferrule Fuses
Size: 20x127
Features/Benefits:
•• Full range D.C. operation
•• 20x127mm ceramic cylindrical body
•• Blown-fuse indicator striker

Catalog Numbers, Ratings
Size

Current

Interrupting Watts Loss

(Mm)

Rating IN(A)

Rating

6

x
127

0.8 IN

IN

New

Old

2.0

3.5

CC 1051 CP gRB 20x127/6

D 100 gRB 006 VI

Ref. No.
Z088020

8

2.2

3.8

CC 1051 CP gRB 20x127/8

D 100 gRB 008 VI

T088774

10

2.4

4.2

CC 1051 CP gRB 20x127/10

D 100 gRB 010 VI

A089493

3.0

5.3

CC 1051 CP gRB 20x127/12

D 100 gRB 012 VI

B089494

12
27

Catalog Number

16

@ 1000V DC

3.7

6.6

CC 1051 CP gRB 20x127/16

D 100 gRB 016 VI

C089495

20

100kA

4.4

7.7

CC 1051 CP gRB 20x127/20

D 100 gRB 020 VI

D089496

25

L/R = 20ms

5.1

9

CC 1051 CP gRB 20x127/25

D 100 gRB 025 VI

E089497

32

6.0

10.5

CC 1051 CP gRB 20x127/32

D 100 gRB 032 VI

F089498

40

7.3

13.2

CC 1051 CP gRC 20x127/40

D 100 gRB 040 VI

S086795

50

8.5

15.5

CC 1051 CP gRC 20x127/50

D 100 gRB 050 VI

F086186

63

9.6

17.4

CC 1051 CP gRC 20x127/63

D 100 gRB 063 VI

F083656

Blown fuse indicator minimum trip voltage: 50 V 			
•Use R.M.S. current less than 56 A when mounting in fuse holder.

Ratings:
Volts	
Amps	
IR	
L/R	

: 1000VDC
: 6 to 63A 		
: 100kA I.R.
: 20mSec

Max. AC Voltage
(50/60Hz)
1500V@100kA I.R.

		

Dimensions
127mm

7mm indicator travel

Approvals:
x 20.6

CC 1051

x5

•• UL recognized component File
E76491

Indicator Trip Force: 4.5N (1lb) at 0mm-2.5N (1/2lb) at 7mm (1/4”)

G22

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

1000V DC Ferrule Fuses
Size 36x127
gRB-gRC from 25 to 100 A

Features/Benefits:
•• Full range D.C. operation
•• 36x127mm ceramic cylindrical body
•• Blown-fuse indicator striker

Catalog Numbers, Ratings
Current

Interrupting Watts Loss

(Mm)

Rating IN(A)

Rating

25

36
x
127

Catalog Number

0.8 IN

IN

New

Old

5.3

9.4

CC 1051 CP gRB 36x127/25

D 100 gRB 006 VI

Ref. No.
H083980

32

6.4

11.5

CC 1051 CP gRB 36x127/32

D 100 gRB 008 VI

R086495

40

6.5

11.6

CC 1051 CP gRB 36x127/40

D 100 gRB 010 V I

G089499

50
63
80
100

@ 1000V DC
100kA
L/R = 20ms

D 100 gRB 012 VI
8.7

15.4

CC 1051 CP gRB 36x127/50

D 100 gRB 016 VI

H089500

10.5

18.8

CC 1051 CP gRC 36x127/63

D 100 gRB 020 VI

J089501

11.9

21.5

CC 1051 CP gRC 36x127/80

D 100 gRB 025 VI

A083651

13.2

24.1

CC 1051 CP gRC 36x127/100

D 100 gRB 032 VI

Z083650

Ratings:
Volts	

: 1000VDC

Amps	 : 25 to 100A
IR	

: 100kA I.R.

L/R	

: 20mSec

G

Size

	
Max AC Voltage

Blown fuse indicator minimum trip voltage: 50 V

(50/60Hz)		
1500V @100k A I.R.

Dimensions
Minimum
indicator
travel

		

Trip force: 4.5N (1lb) at 0 mm - 2.5N (1/2) at 7 mm

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G23

1500V DC Ferrule Fuses
Size: 20x127
Features/Benefits:
•• Blown fuse indicator striker .8 to 5A
•• 20x127mm ceramic cylindrical body
•• Full range D.C. operation

Catalog Numbers, Ratings
Size
(Mm)

Current
Rating

Interrupting
Rating

Watts Loss

Catalog Number
Ref. No.

0.8 IN

IN

New

Old

0.8

0.5

0.9

CC 1551 CP gRB 20x127/0.8

D 150 gRB 0.8 VI

E075743

1

0.5

0.9

CC 1551 CP gRB 20x127/1

D 150 gRB 001 VI

F075744

IN(A)

1.5

@ 1000V DC

0.8

1.4

CC 1551 CP gRB 20x127/1.5

D 150 gRB 01.5 VI

G075745

2

100kA

0.9

1.6

CC 1551 CP gRB 20x127/2

D 150 gRB 002 VI

B088367

3.15

L/R = 100ms

4

1.2

2.1

CC 1551 CP gRB 20x127/3.15

D 150 gRB 3.15 VI

H075746

1.3

2.1

CC 1551 CP gRB 20x127/4

D 150 gRB 004 VI

J075747

5

1.4

2.3

CC 1551 CP gRB 20x127/5

D 150 gRB 005 VI

C088368

0.8

0.5

0.9

CC 1500 CP gRB 20x127/0.8

D 150 gRB 0.8 V

J081842

1

0.5

0.9

CC 1500 CP gRB 20x127/1

D 150 gRB 001 V

R079894

20

1.5

@ 1500V DC

0.8

1.4

CC 1500 CP gRB 20x127/1.5

D 150 gRB 01.5 V

K081843

x

2

30kA

0.9

1.6

CC 1500 CP gRB 20x127/2

D 150 gRB 002 V

Y099243

127

3.15

L/R = 30ms

4

1.2

2.1

CC 1500 CP gRB 20x127/3.15

D 150 gRB 3.15 V

L081844

1.3

2.1

CC 1500 CP gRB 20x127/4

D 150 gRB 004 V

Z099244

5

1.4

2.3

CC 1500 CP gRB 20x127/5

D 150 gRB 005 V

A099245

6

3.4

6.3

CC 1500 CP gRD 20x127/6

D 150 gRB 006 V

E082804

8

3.3

6.0

CC 1500 CP gRD 20x127/8

D 150 gRB 008 V

Z080867

10

@ 1500V DC

3.5

6.1

CC 1500 CP gRD 20x127/10

D 150 gRB 010 V

F081655

12

30kA

3.9

6.8

CC 1500 CP gRD 20x12712

D 150 gRB 012 V

B080593

16

L/R = 55ms

5

8.9

CC 1500 CP gRD 20x127/16

D 150 gRB 016 V

Q081457

20

5.3

9.6

CC 1500 CP gRD 20x127/20

D 150 gRB 020 V

D082803

25

6.6

12

CC 1500 CP gRD 20x127/25

D 150 gRB 025 V

A080431

Ratings:
CC 1551 CP gRB
Volts	 : 1000VDC
Amps	 : 0.8 to 5A
IR	
: 100kA I.R. DC
L/R	
: 100mSec
CC 1500 CP gRB
Volts	 : 1500VDC
Amps	 : 0.8 to 25 Amps
IR	
: 30kA I.R. DC
L/R	
: 30mSec (.8 to 5A)
L/R	
: 55mSec (6 to 25A)
Max AC Voltage (50/60Hz)
2500@50k A.I.R.

Blown fuse indicator minimum trip voltage: 50 V 			

Dimensions
127mm

x 20.6

7mm indicator travel

x5

Indicator Trip Force: 4.5N (1lb) at 0mm-2.5N (1/2lb) at 7mm (1/4”)

G24

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

1500V DC Ferrule Fuses
Size: 20x190
Features/Benefits:
•• Blown-fuse indicator striker
CC I59I CP gRC
•• 20x190 ceramic cylindrical body
•• Full range D.C. operation
•• CC 1500, without indicator	

Catalog Numbers, Ratings

20
x
190

Current

Interrupting

Watts Loss

Rating IN(A)

IN(A)

0.8 IN

IN

Catalog Number

Ref. No.

6

4.8

7.8

CC 1591 CP gRC 20x190/6

D083102

8

5.3

8.8

CC 1591 CP gRC 20x190/8

V083738

10

6.5

10.5

CC 1591 CP gRC 20x190/10

G087245

12

7.0

11.5

CC 1591 CP gRC 20x190/12

Y080429

16

8.0

13

CC 1591 CP gRC 20x190/16

N088378

20

9.5

15

CC 1591 CP gRC 20x190/20

Q087345

25

12

19.5

CC 1591 CP gRC 20x190/25

Z080430

16

26

CC 1591 CP gRC 20x190/32

G085911

4.8

7.8

CC 1500 CP gRC 20x190/6

Z089469

5.3

8.8

CC 1500 CP gRC 20x190/8

A089470

10

6.5

10.5

CC 1500 CP gRC 20x190/10

B089471

12

7.0

11.5

CC 1500 CP gRC 20x190/12

C089472

16

8.0

13

CC 1500 CP gRC 20x190/16

D089473

20

9.5

15

CC 1500 CP gRC 20x190/20

E089474

25

12

19.5

CC 1500 CP gRC 20x190/25

F089475

32

16

26

CC 1500 CP gRC 20x190/32

G089476

32
6
8

@ 1500V DC
60kA
L/R = 40ms

Ratings:
Volts	 : 1500VDC
Amps	 : 6 to 32A
IR	
: 60kA I.R. DC
L/R	

: 40mSec

G

Size

Max AC Voltage (50/60 Hz)	
3000V @ 50k A I.R.

		

Dimensions
190

x 20.6

7mm

x

5

Weight: 176 g

Indicator Trip Force: 4.5N (1lb) at 0mm - 2.5N (1/2lb) at 7mm (1/4”) - when so
equipped*

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G25

1500V DC Ferrule Fuses
Size 36x190
gRC-gRD from 40 to 100 A

Features/Benefits:
•• Full range D.C. operation
•• 36x190mm ceramic cylindrical body
•• CC 1591, with indicator
•• CC 1500, without indicator

Catalog Numbers, Ratings
Size

Current

Interrupting

Rating IN(A)

IN(A)

40

36
x
190

Watts Loss
0.8 IN

IN

Catalog Number

Ref. No.

14

26

CC 1591 CP gRC 36x190/40

M080419

16.5

30

CC 1591 CP gRC 36x190/50

N080420

50

@ 1500 VDC

63

60kA

20.6

38

CC 1591 CP gRC 36x190/63

P080421

80

L/R = 60 ms

18

33

CC 1591 CP gRD 36x190/80

N221134

100

23

42

CC 1591 CP gRD 36x190/100

Y220154

40

14

26

CC 1500 CP gRC 36x190/40

H089477

16.5

30

CC 1500 CP gRC 36x190/50

J089478

50

@ 1500 VDC

63

60kA

20.6

38

CC 1500 CP gRC 36x190/63

K089479

80

L/R = 30 ms

18

33

CC 1500 CP gRD 36x190/80

Q078007

23

42

CC 1500 CP gRD 36x190/100

K078025

100

Rating:
Volts	 : 1500VDC
Amps	 : 40 to 100A
IR	

: 60kA I.R. DC

Max AC Voltage (50/60 Hz) 3000V
@ 50k A I.R.
CC1591	: L/R=60mSec
CC1500	: L/R=30mSec

	

Dimensions

Trip Force: 4.5N (1lb) at 0 mm-2.5N (1/2lb) at 7mm (1/4”) when so equipped

G26

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

4000V DC Ferrule Fuses
Size 36x400
gRC from 0.8 to 20 A

Features/Benefits:
•• Full range D.C. operation
•• 36x400mm ceramic cylindrical body

Catalog Numbers, Ratings
Current

Interrupting

Rating IN(A)

IN(A)

Watts Loss

Catalog Number

Ref. No.

0.8 IN

IN

.08

1.5

2.5

CC 4000 CP gRC 36x400/0.8

Z220293

1

1.6

2.7

CC 4000 CP gRC 36x400/1

R221137

1.5

2.4

14.1

CC 4000 CP gRC 36x400/1.5

S221138

2

3.0

5.0

CC 4000 CP gRC 36x400/2

Z089423

3.15

3.9

6.4

CC 4000 CP gRC 36x400/3.15

T221139

36

4

@ 4000 V DC

6.0

10

CC 4000 CP gRC 36x400/4

A089424

x

5

30kA

9.6

16

CC 4000 CP gRC 36x400/5

Y098461

400

6

L/R = 20 ms

Ratings:
Volts	: 4000VDC
Amps	: .8 to 20A

11

19

CC 4000 CP gRC 36x400/6

E099847

IR	

: 30kA I.R. DC

8

12

22

CC 4000 CP gRC 36x400/8

V221140

L/R	

: 20mSec

10

13

23

CC 4000 CP gRC 36x400/10

G098469

12

15

26

CC 4000 CP gRC 36x400/12

C098396

16

15

27

CC 4000 CP gRC 36x400/16

Z083052

20

18.6

33

CC 4000 CP gRC 36x400/20

F099848

G

Size

4000VAC @ 50kA I.R.

		

Dimensions
400
(15.75”)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G27

750V DC Square Body Fuses
Size: 120
Features/Benefits:
•• Blown-fuse indicator 	
•• Square ceramic body
•• Full range D.C. operation
•• Bladed and tapped versions standard

Catalog Numbers, Ratings
Current
Size

Interrupting

Watts Loss

Catalog Number

Ref. No.

8.1

CC 7,5 gRC 120 EF 0050

Y084776

5.7

10.4

CC 7,5 gRC 120 EF 0063

R085207

7.3

13.4

CC 7,5 gRC 120 EF 0080

Q085206

16.7

9.1

16.7

CC 7,5 gRC 120 EF 0100

P085205

11.5

21

11.5

21

CC 7,5 gRC 120 EF 0125

R086242

160

15

27

15

27

CC 7,5 gRC 120 EF 0160

N085204

50

4.4

8.1

4.4

8.1

CC 7,5 gRC 120 TTF 0050

B220824

63

5.7

10.4

5.7

10.4

CC 7,5 gRC 120 TTF 0063

Q082400

7.3

13.4

7.3

13.4

CC 7,5 gRC 120 TTF 0080

Z090435

9.1

16.7

9.1

16.7

CC 7,5 gRC 120 TTF 0100

R082401

11.5

21

11.5

21

CC 7,5 gRC 120 TTF 0125

P085251

15

27

15

27

CC 7,5 gRC 120 TTF 0160

R085253

Rating

IN(A)

IN(A)
50
63

@ 750V=

80

100kA

100

L/R = 100ms

125
120

Maximum l2t
@900V=L/R 40ms

@ 900 V=

80

100kA

100

L/R = 40ms

125
160

Ip=101N

Ip=501N

4.4

8.1

4.4

5.7

10.4

7.3

13.4

9.1

0.8 IN

IN

Ratings:
Volts	 : 750VDC
	
: 900VDC
Amps	 : 50 to 160A
IR	

: 100kA I.R. DC

L/R	

: 100mSec (750)

L/R	

: 40mSec (900)

Microswitch: MC 3E 1-5N Ref. Number: D310020
Contact factory for holder

Dimensions
39
6

181
124
CC.... 120 E ...

18

53
9

41

66.5

Weight: 579 g

28

156
126
124
M8
tapped 9mm
deep

G28

39

CC.... 120 TTF...
53

41

28

56.5

Weight: 574 g

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

750V DC Square Body Fuses
Size: 121
Features/Benefits:
•• Blown-fuse indicator 	
•• Square ceramic body
•• Full range D.C. operation
•• Bladed and tapped versions standard

Catalog Numbers, Ratings
Size

Rating
IN(A)

121

Maximum l2t

Interrupting

Watts Loss

@900V=L/R 40ms

IN(A)

Ip=101N

Ip=501N

0.8 IN

Catalog Number

Ref. No.

IN

200

@ 750V DC

755000

150000

20.5

37.5

CC 7,5 gRC 121 EF 0200

A086710

250

100kA L/R = 100ms

1250000

250000

25.5

46.7

CC 7,5 gRC 121 EF 0250

M085203

200

@900V DC

755000

150000

20.5

37.5

CC 7,5 gRC 121 TTF 0200

N085250

Ratings:

250

100kAL/R = 40ms

1250000

250000

25.5

46.7

CC 7,5 gRC 121 TTF 0250

Q085252

Volts	: 750VDC
	

Microswitch: MC 3E 1-5N Ref. Number: D310020
Contact factory for holder

Amps	: 200 & 250A

Dimensions
51
6

191
129
CC.... 121 E ...

25

63
11

: 900VDC

G

Current

51

IR	

: 100kA I.R.

L/R	

: 100mSec (750V)

L/R	

: 40mSec (900V)

66.5

28

Weight: 825 g

166
51

131
129
M8
Tapped
9mm deep

CC.... 121 TTF...
63

51

28

66.5
Weight: 796 g

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G29

750V DC Square Body Fuses
Size: 122
Features/Benefits:
•• Blown-fuse indicator 		
•• Square ceramic body
•• Full range D.C. operation
•• Bladed and tapped versions standard

Catalog Numbers, Ratings
Current
Size

Rating
IN(A)

IN(A)

Maximum l2t

Watts Loss

@900V=L/R 40ms

Catalog Number

Ref. No.

46.7

CC 7,5 gRC 122 EF 0250

A087331

58

CC 7,5 gRC 122 EF 0315

B087332

35

64.5

CC 7,5 gRC 122 EF 0350

W221141

40.5

74.5

CC 7,5 gRC 122 EF 0400

L089388

800,000

49

90

CC 7,5 gRD 122 EF 0450

P220951

1.25x106*

52

95

CC 7,5 gRD 122 EF 0500

Q220952

250,000

25.5

46.7

CC 7,5 gRC 122 TTF 0250

B090437

400,000

31.5

58

CC 7,5 gRC 122 TTF 0315

M085249

IR	

: 100kA I.R. DC 	

64.5

CC 7,5 gRC 122 TTF 0350

G220898

L/R	

: 100mSec (750V)

L/R	

: 40mSec (900V)

Ip=101N

Ip=501N

250

1.25x106

250,000

25.5

315

2x106

400,000

31.5

6

500,000

3.1x106

600,000

4x106
6.2x106*

350
400
450
122

Interrupting

@ 750V=

2.5x10

100kA
L/R = 100ms

500

1.25 x106

250

2x106

315

0.8 IN

IN

350

2.5x106

500,000

35

400

3.1x106

600,000

40.5

74.5

CC 7,5 gRC 122 TTF 0400

C090438

450

4x106*

800,000

49

90

CC 7,5 gRD 122 TTF 0450

R220953

500

6.2x106*

1.25x106*

52

95

CC 7,5 gRD 122 TTF 050

S220954

Ratings:
Volts	

: 750VDC

	

: 900VDC

Amps	 : 250 to 500A

*MAX. I2t @ 800V=, L/R=40ms
Microswitch: MC 3E 1-5N Ref. Number: D310020
Contact factory for holder

Dimensions
60
6

206
129
32

CC.... 122 E ...

60
72
13

65.5

28

Weight: 1,210 g

171
131
129

60

CC.... 122 TTF...
M10
Tappped
9mm deep

G30

60
72
28

65.5
Weight: 1,150 g

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

660-750V DC Square Body Fuses
Size: 123
Features/Benefits:
•• Blown-fuse indicator 	
•• Square ceramic body
•• Full range D.C. operation
•• Bladed and tapped versions standard

Catalog Numbers, Ratings
Rating
IN(A)
500
500

Maximum l2t

Interrupting
IN(A)
@750VDC 100kA
L/R=100ms
@900VDC 100kA
L/R = 40ms

Watts Loss

@900V=L/R 40ms

Catalog Number

Ref. No.

Ip=101N

Ip=501N

5x106

1x106

51

93.5

CC 7,5 gRC 123 EF 0500

M089389

5x106

1x106

51

93.5

CC 7,5 gRC 123 TTF 0500

D090439

0.8 IN

IN

maximum I t (A s)
@800V = L/R 40ms
Ip=10 I
Ip=50 I
2

2

N

123

N

Ratings:
CC 7.5gRC
Volts	

: 750VDC

	

: 900VDC

630

7.5x10

74

CC 7,5 gRB 123 EF 0630

B098556

Amps	 : 500A

700

10x106

2x106

82

CC 7,5 gRB 123 EF 0700

Q078191

IR	

: 100kA I.R. DC

750

10x10

2x10

82

CC 7,5 gRD 123 EF 0750

F220943

L/R	

: 100mSec (750V)

L/R	

: 40mSec (900V)

1.5x10

6

6

@750VDC
100kA
L/R=50ms

6

6

630

7.5x106

1.5x106

74

CC 7,5 gRB 123 TTF 0630

C098557

700

10x106

2x106

82

CC 7,5 gRB 123 TTF 0700

F090441

750

10x10

2x106

82

CC 7,5 gRD 123 TTF 0750

H220945

6

maximum I2t (A2s)
@660V = L/R 30ms
Ip=10 I
Ip=50 I

800

@660VDC
100kA
L/R=50ms

CC 7.5gRB, gRD
Volts	

: 750VDC

Amps	 : 630 to 750A
IR	

: 100kA I.R. DC

12.15x106

2.6x106

90

CC 6.6 gRB 123 EF 0800

G220944

L/R	

: 50mSec

12.15x106

2.6x106

90

CC 6.6 gRB 123 TTF 0800

J220946

CC 6.6gRB

N

800

G

Current
Size

N

Volts	

: 660VDC

Amps	 : 800A
Contact factory for holder

Dimensions
75
206
129
40

6

CC.... 123 E...

75
87
13

M12
Tapped
9mm deep

171
131
129
CC.... 123 TTF ...

90.5

28

Weight: 1,820 g

IR	

: 100kA I.R. DC

L/R	

: 50mSec

Rated

Max. Operating

Current (A)

Current (A)

630

550

700

600

750

600

800

650

75
75
87

90.5
Weight: 1,800 g

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G31

750V DC Square Body/Special Purpose
Size 2x122
gRC - gRD from 500 to 900 A

Catalog Numbers, Ratings
Current
Size

Rating
IN(A)
500
630
800

2

900

Interrupting
IN(A)
@ 900V DC
100kA
L/R = 40ms

x

Maximum l2t

Watts Loss

@900V=L/R 40ms
Ip=101N

Ip=501N

5x106

1x106

51

8x106

1.6x106

63
6

2.4x10

81

3.2x106

98

12.4x10

6

16x106

0.8 IN

Catalog Number

Ref. No.

94

CC 7,5 gRC 2122 TTF 0500

Q090473

116

CC 7,5 gRC 2122 TTF 0630

R090474

149

CC 7,5 gRC 2122 TTF 0800

S090475

180

CC 7,5 gRD 2122 TTF 0900

T220955

IN

maximum I t (A s)
@800V = L/R 40ms
Ip=50 I
Ip=10 I
2

122

N

2

N

@750VDC
1000

100kA

25x106

4.8x106

104

CC 7,5 gRD 2122 TTF 1000

V220956

L/R=50ms
Microswitch: MC 3E 1-5N Ref. Number: D310020

Ratings:
Volts	

: 900VDC

	

: 750VDC

Amps	 : 500 to 1000A

Dimensions

IR	

: 100kA I.R. 	

L/R	

: 40mSec (900V)

L/R	

: 100mSec (750V)

Weight: 2,825g

G32

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

660-750V DC Square Body/Special Purpose
Size 2x123
gRC - gRB, gRD, gRC - gRD from 1000 to 1600A

Catalog Numbers, Ratings
Current
Size

Rating
IN(A)

Interrupting
IN(A)

Maximum l2t

Watts Loss

@900V=L/R 40ms
Ip=101N

Ip=501N

20x106

4x106

0.8 IN

Catalog Number

Ref. No.

CC 7,5 gRC 2123 TTF 1000

Z090481

IN

@750VDC 100kA

1000

L/R=100ms
@900VDC 100kA

102

87

L/R = 40ms
maximum I2t (A2s)
@800V = L/R 40ms
Ip=10 I

N

1250

30x10

Ip=50 I

N

6x106

148

CC 7,5 gRB 2123 TTF 1250

D098558

40x106

8x106

164

CC 7,5 gRB 2123 TTF 1400

B090483

40x106

8x106

164

CC 7,5 gRB 2123 TTF 1500

K220947

6

@750VDC

1400

x
123

100kA
L/R=50ms

1500

maximum I2t (A2s)

N

1600

Ip=50 I

N

@660VDC

48.6x106

100kA

10x106

Volts	

: 900VDC

	

: 750VDC

	

: 660VDC

Amps	 : 1000 to 1600A

@660V = L/R 30ms
Ip=10 I

Ratings:
G

2

90

CC 6.6 gRB 2123 TTF 1600

L220948

L/R=50ms

IR	

: 100kA I.R.

L/R	

: 40mSec (900V, 1000A)

L/R	

: 50mSec (125 to 1500A)

L/R	

: 100mSec (750V, 1000A)

Microswitch: MC 3E 1-5N Ref. Number: D310020

Dimensions

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Rated

Max. Operating

Current (A)

Current (A)

1250

1100

1400

1200

1500

1200

1600

1300

www.barr-thorp.com

G33

1200V DC Square Body
Size 72
SRG from 160 to 420 A

Catalog Numbers, Ratings
Current
Size

Rating
IN(A)

72

Interrupting
IN(A)

Maximum l2t
@1000V=
L/R=15ms

L/R=45ms

Watts Loss
0.8 IN

Catalog Number

Ref. No.

IN

160

12000

20000

41

77.5

CC 12 SRG 72 QF 0160

K079428

200

21000

36000

48

88

CC 12 SRG 72 QF 0200

L079429

250
315
400

@ 900V DC
100kA
L/R = 40ms

420

45500

78500

57

96

CC 12 SRG 72 QF 0250

M079430

90000

154000

60

110

CC 12 SRG 72 QF 0315

N079431

182000

314000

66

129

CC 12 SRG 72 QF 0400

P079432

220000

380000

67

131

CC 12 SRG 72 QF 0420

Q079433

Microswitch: MC 3E 1-5N Ref. Number: D310020

Volts	

Dimensions

G34

Ratings:
: 1200VDC

Amps	 : 160 to 420A

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

IR	

: 100kA I.R.

L/R	

: 15mSec

www.barr-thorp.com

2000V DC Square Body
Size 120
SRC from 20 to 215 A

Catalog Numbers, Ratings
Size

@1000V=

Watts Loss

Catalog Number

Ref. No.

16

CC 20 SRC 120 QF 0020

J079450

25

CC 20 SRC 120 QF 0025

K079451

14.5

29.5

CC 20 SRC 120 QF 0032

L079452

17.5

36

CC 20 SRC 120 QF 0040

M079453

1800

20.5

42

CC 20 SRC 120 QF 0050

N079454

1600

2800

26

53.5

CC 20 SRC 120 QF 0063

P079455

3100

5400

30

61.5

CC 20 SRC 120 QF 0080

Q079456

5800

10000

35

70.5

CC 20 SRC 120 QF 0100

R079457

125

9200

16000

43

87.5

CC 20 SRC 120 QF 0125

S079458

160

19200

33200

49

99

CC 20 SRC 120 QF 0160

T079459

200

45000

78500

49.5

101

CC 20 SRC 120 QF 0200

V079460

215

55000

95000

52

106

CC 20 SRC 120 QF 0215

W079461

Rating
IN(A)

120

Maximum l2t

Interrupting
IN(A)

L/R=15ms

L/R=45ms

20

180

310

8

25

180

310

12.5

32

350

610

40

580

1000

50

1030

63
80
100

@ 2000VDC =
100kA
L/R = 15ms

0.8 IN

IN

Microswitch: MCR 3E 1-5N BS Ref. Number: D310023

Ratings:
Volts	

: 2000VDC

Amps	 : 20 to 215A
IR	

: 100kA I.R.

L/R	

: 15mSec

G

Current

Dimensions

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G35

2000V DC Square Body
Size 122
SRD from 160 to 400 A

Catalog Numbers, Ratings
Current
Size

Rating
IN(A)

122

Interrupting
IN(A)

Maximum l2t
@100V=
L/R=15ms

L/R=45ms

Watts Loss
0.8 IN

Catalog Number

Ref. No.

IN

160

@ 1800VDC

15000

25000

52.5

100

CC 20 SRD 122 QF 0160

D076639

200

100kA

26000

44000

61.5

118

CC 20 SRD 122 QF 0200

X079462

250

L/R = 30ms

50000

87000

69

131

CC 20 SRD 122 QF 0250

Y079463

315

@ 2000VDC

117000

200000

74

150

CC 20 SRD 122 QF 0315

Z079464

219000

380000

87

175

CC 20 SRD 122 QF 0400

A079465

400

100kA
L/R = 15ms

Microswitch: MCR 3E 1-5N BS Ref. Number: D310023

Ratings:

Dimensions

Volts	

: 1800VDC

	

: 2000VDC

Amps	 : 160 to 400A

G36

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

IR	

: 100kA I.R.

L/R	

: 30mSec (1800V)

L/R	

: 15mSec (2000V)

www.barr-thorp.com

3500-4000V DC Square Body
Size 600
gRB - grD from 6 to 125 A

Catalog Numbers, Ratings
Rating
IN(A)

600

Watts Loss

Interrupting
IN(A)

0.8 IN

Catalog Number

Ref. No.

IN

6

5.3

9.5

CC 35 gRB 600 QF 0006

S083736

8

7

12.7

CC 35 gRB 600 QF 0008

R083735

10

@ 3500 V DC

10.2

18.5

CC 35 gRB 600 QF 0010

N089390

12

30kA

11

20

CC 35 gRB 600 QF 0012

V082220

16

L/R = 30 ms

13.1

24

CC 35 gRB 600 QF 0016

P089391

20

14

25.4

CC 35 gRB 600 QF 0020

Q089392

25

18

32.5

CC 35 gRB 600 QF 0025

R089393

32

25.5

46

CC 40 gRB 600 QF 0032

A086963

40

@ 4000 V DC

35

63

CC 40 gRB 600 QF 0040

B086964

50

30kA

29

52

CC 40 gRB 600 QF 0050

C086965

63

L/R = 30 ms

42

76.5

CC 40 gRB 600 QF 0063

D086966

80

51

92

CC 40 gRB 600 QF 0080

E086967

80

@ 4000 V DC

3.9

67

CC 40 gRD 600 QF 0080

B075763

100

30kA

50.5

88

CC 40 gRD 600 QF 0100

C075764

125

L/R = 30 ms

63

110

CC 40 gRD 600 QF 0125

D075765

Ratings:
Volts	

: 3500VDC

	

: 4000VDC

G

Current
Size

Amps	 : 6 to 125A
IR	

: 30kA I.R.

L/R	

: 30mSec

Microswitch: 2R 3E 1-5N BS Ref. Number: J310025

Dimensions

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G37

HP6M 600V DC Photovoltaic Fuses
About the HP6M Fuse
Mersen’s HP6M photovoltaic (PV) fuse series was engineered and designed specifically
for the protection of photovoltaic systems. Its enhanced fuse construction makes it ideal
for continuous temperature and current cycling withstand adding to system longevity. The
600VDC rated HP6M, designed for low minimum breaking capacity capabilities of 1.35
times the fuse rated current value, allows for safe circuit interruption under typical low fault
current conditions produced by PV arrays. Protect your off-grid or grid tied PV system from
unexpected ground faults and line faults using Mersen’s Helio Protection fuse line.

Features/Benefits:

Applications:

•• Low fault current interrupting

•• All photovoltaic applications
•• PV string/array level protection

capability
•• Durable construction for enhanced

•• Combiner box applications
•• In-line PV module protection

system longevity
•• Temperature cycle withstand

•• Inverters
•• Battery charge controllers

capability
•• Guaranteed operation at

Volts	

temperature extremes
•• Globally accepted

HP6M1

: 600VDC

Amps	 : 1 to 30A

•• Industries first UL Listed Solution

Catalog Numbers (amps)

Ratings:

Catalog Numbers - Fuse Holder

HP6M8

UltraSafe™

UltraSafe™

HP6M2

HP6M10

Non-Indicating

Indicating

HP6M3

HP6M12

US101HEL

US101IHEL

HP6M4

HP6M15

HP6M5

HP6M20

HP6M6

HP6M25

HP6M7

HP6M30

IR	

: 10kA I.R. DC

MBC	

: 1.35 x In

	
Photovoltaic Fuse, gPV	
	

Approvals:
•• UL Listed to Standard UL2579

Dimensions	

File E333668
•• CSA Component Certified C22.2
•• IEC 60269-6 Approved

G38

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

HP10M 1000V DC Photovoltaic Fuses
Engineered to protect photovoltaic applications
Mersen’s HP10M photovoltaic (PV) fuse series was engineered and designed
specifically for the protection of photovoltaic systems. Its enhanced fuse construction
makes it ideal for continuous temperature and current cycling withstand adding to
system longevity. The 1000VDC rated HP10M, designed for low minimum breaking
capacity capabilities of 1.35 times the fuse rated current value, allows for safe circuit
interruption under typical low fault current conditions produced by PV arrays. Protect
your off-grid or grid tied PV system from unexpected ground faults and line faults
using Mersen’s Helio Protection fuse line.

●● Low fault current interrupting
capability
●● Durable construction for enhanced
system longevity
●● Temperature cycle withstand
capability
●● Guaranteed operation at temperature
extremes
●● Industries first UL Listed Solution
●● Globally accepted

Catalog Numbers (amps)

Applications:
•• All photovoltaic applications
•• PV string/array level protection
•• Combiner box applications
•• In-line PV module protection

Ratings:

•• Inverters

Volts	

•• Battery charge controllers

Catalog Numbers - Fuse Holder

HP10M1

HP10M7

UltraSafe™

UltraSafe™

HP10M2

HP10M8

Non-Indicating

Indicating

HP10M3

HP10M10

US101HEL

US101IHEL

HP10M4

HP10M12

HP10M5

HP10M15

HP10M6

HP10M20

: 1000VDC

Amps	: 1 to 20A
IR	

: 10kA I.R. DC

MBC	

: 1.35 x In

G

Features/Benefits:

	
Photovoltaic Fuse, gPV

Approvals:
•• UL Listed to Standard UL2579

Dimensions	 	

File E333668
•• CSA Component Certified C22.2
•• IEC 60269-6 Approved

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G39

HP6J 600V DC Photovoltaic Fuses
About the HP6J Fuse
Mersen’s HP6J photovoltaic (PV) fuse series was engineered and designed
specifically for the protection of photovoltaic systems. Its enhanced fuse construction
makes it ideal for continuous temperature and current cycling withstand adding to
system longevity. The 600VDC rated HP6J designed for low minimum breaking
capacity capabilities of 1.35 times the fuse rated current value allows for safe circuit
interruption under typical low fault current conditions produced by PV arrays. Protect
your off-grid or grid tied PV system from unexpected ground faults and line faults
using Mersen’s Helio Protection fuse line.

Features/Benefits:

Applications:

•• Smallest footprint in the industry

•• Re-combiner (sub-combiner,

•• Low fault current interrupting

array combiner, master combiner)

capability

applications

•• Durable construction for enhanced
system longevity

•• Inverter DC input protection
•• Battery charge controllers

•• Temperature cycle withstand

Ratings:
Volts	

: 600VDC

Amps	: 70 to 400A

capability
•• Guaranteed operation at
temperature extremes

IR	

: 10kA I.R. DC

MBC	

: 1.35 x In

	

•• Industries first UL Listed Solution

Photovoltaic Fuse, gPV	

•• Globally accepted

	

Catalog Numbers (amps)
HP6J70

HP6J175

HP6J80

HP6J200

HP6J90

HP6J225

HP6J100

HP6J250

HP6J110

HP6J300

Approvals:

HP6J125

HP6J350

•• UL Listed to Standard UL2579

HP6J150

HP6J400

File E333668
•• CSA Component Certified C22.2

Catalog Numbers - Fuse Holder
Wire Terminal

Ampere

Clip

Catalog

Rating

Input

Output

Configuration

Number

100

Stud

Stud

In-line Clip

61016J

200

Stud

Stud

Side Clip

62011J

400

Stud

Stud

In-line Clip

64011J

These fuse holders are suitable for use on circuits capable of delivering a maximum fault current of 10kA.
The wire connectors for these fuse holders will be supplied in the end-use.

G40

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

HP6J 600V DC Photovoltaic Fuses
Dimensions - HP6J(70-100)

G

Dimensions - HP6J(110-200)

Dimensions - HP6J(225-400)

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

G41

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fuse Blocks & Holders
“Finger-safe” IEC, Traditional, Panel Mount... You name the block, we’ve got it in stock.

Your problem:
of standard fuse
blocks to meet
industrial require-

H

Fuse Blocks & Holders

• UltraSafe™ USCC & USM................ H2

ments. You need

• UltraSafe™ USFM............................ H4

DIN-rail mount-

• UltraSafe™ US3J & US6J................. H6

ing fuse holders
that save space
and conform with today’s “Finger-safe” IEC standards. You need

• UltraSafe™ US14 & US22................ H8
• Open Style Class J & SJ Series...... H12

panel-mount fuse holders, blocks that safely handle stress on

• Open Style Midget & Class CC....... H16

conductors, accessories to make pulling fuses safer.

• Open Style Class H, K & R............. H18

Our solution: Mersen’s extensive line of fuses is matched by our

• Open Style Class T......................... H25

line of fuseblocks. Need a durable Class H, K, or R block? We’ve

• Open Style Class G......................... H30

got configurations that accept nearly all 250 and 600V power

• Open Style Miniature....................... H32

fuses. How about Class CC or Class J IEC-style holders? Turn to
our popular UltraSafe™ models for the small footprints, blownfuse indicators, and finger-safe changeouts you want. The same
goes for traditional Class J blocks, space-saving “SJ” blocks,
600V Class CC and midget dimension holders, and a dozen other
fuse holder solutions.

• In-Line Fuse Holders / FEB, FEC, FEX,
FEY Series - Midget/Class CC........ H33
• Panel Mount Fuse Holders /
GPM Series..................................... H37
• Semiconductor Fuse Blocks /
P243/P266/P292............................ H44

Want more information fast? For more technical or applicationspecific information, please call our Fuse Block experts, at
978-462-6662; 416-252-9371 in Canada; or visit our website at
us-ferrazshawmut.mersen.com.

• Modular Semiconductor Fuse Blocks /
1SC/1MSC...................................... H45
• Semiconductor Fuse Holders / 703,
U705, U710 Series.......................... H46
• Ferrule Fuse Holders / PS20x127... H48
• Fuse Bases / NH Dimension........... H50
• Dead Front Fuse Covers /
DFC Series...................................... H55
• Fuse Block Accessories /
DFC3M, DFC3LP & DRM............... H57
• Ferrule Fuse Clips / PC Board
Mount Fuse Clips............................ H58

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H

You need a range

USCC & USM UltraSafe

TM

Fuseholders

UltraSafe modular fuse holders for midget and class CC fuses
Mersen UltraSafe Modular Fuse Holders introduce a new level of safety for Class CC
(USCC) and Midget 1-1/2” x 13/32” (USM) AC and DC-rated fuses up to 30 amperes.
UltraSafe holders qualify as “Finger-safe” under IEC and DIN standards to an IP20
grade of protection, including fuse changing (with the flick of a finger). UltraSafe
holders are available in 1, 2, 3 or 4 poles, with or without visual blown-fuse indicators
in each pole. Multi-pole units can also be field assembled by ordering pin-tie handles.
UltraSafe holders save up to 15% mounting space and any combination can be
snapped onto 35mm DIN-rail for extra savings in panel building time. UltraSafe
holders with Class CC fuses chosen for Type “2” No Damage protection give one of
the safest protection packages in the industry. UltraSafe body material is tough and
durable polyamide, with exceptional insulating properties.

Highlights:

Applications:

Ratings:

•• IP20 Finger-Safe (touch safe)

•• All circuits up to 600 volts

USM (Midget 10x38mm Fuses)

•• Optional visual blown fuse
Indicator lights
•• DIN-rail mounting

for motors, control circuits,

Volts	

: 800VAC Maximum

transformers, etc…

	

: 1000VAC Maximum

•• DC circuits up to 1000VDC

•• Compact footprint

including photovoltaic applications

•• Quick, tool-free, easy fuse

•• Non-load disconnect

change outs

Amps	 : 30A Maximum
SCCR	 : 100kA
USCC (Class CC Fuses)
Volts	

: 600VAC / DC Maximum

Amps	 : 30A Maximum

Recommended Fuse Usage:
•• USM use with:
ATQ, ATM*, A6Y-2B, A25Z-2, TRM, OTM, A13X-2, A60Q-2,

SCCR	 : 200kA

Min. voltage to operate indicator light: 90VAC,
115VDC [Less than 0.7 mA leakage current
at 600V]

DCT*, HP6M, HP10M

Approvals:

•• USCC use with:
ATDR, ATMR*, ATQR

USM (Midget 10x38mm Fuses)

* Recommended for DC applications

•• UL Recognized Component,
guide IZLT2, File E52283
•• CSA Certified C22.2, class 6225
File 32169 (750VAC, 30A)
•• IEC Compliant (690VAC, 32A)
USCC (Class CC Fuses)
•• UL Listed, guide IZLT, File
E52283
•• CSA Certified C22.2, class 6225
File 32169 (600VAC, 30A)

H2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

USCC & USM UltraSafe

TM

Fuseholders

Catalog Numbers and Descriptions:
Voltage Rating

Ampere

No. of

AC

Rating

Poles

Catalog No.

Catalog No.

W/O Indicator

w/ Indicator

USCC1

USCC1I

1-Pole Class CC UltraSafe Fuse Holder

USCC2

USCC2I

2-Pole Class CC UltraSafe Fuse Holder

USCC3

USCC3I

3-Pole Class CC UltraSafe Fuse Holder

USCC4

USCC4I

4-Pole Class CC UltraSafe Fuse Holder

USCC3N

USCC3IN

3-Pole + N Class CC UltraSafe Fuse Holder

USCC1I-AC120

USCC1I with 120VAC indicator

120

-

1

USCC1I-AC300

USCC1I with 300VAC indicator

300

-

1

-

24

1

Special Indicator
Versions

Description

Fuse Type

DC

1
2
600V

600V

Class CC

3
30A

4

UL Listed

4

CSA Certified

USCC1I-DC24

USCC1I with 24VDC indicator

USM1

USM1I

1-Pole Midget UltraSafe Fuse Holder

1

USM2

USM2I

2-Pole Midget UltraSafe Fuse Holder

2

USM3

USM3I

3-Pole Midget UltraSafe Fuse Holder

USM4

USM4I

4-Pole Midget UltraSafe Fuse Holder

USM3N

USM3IN

3-Pole + N Midget UltraSafe Fuse Holder

USM1I-AC120

USM1I with 120VAC indicator

Special Indicator
Versions

Certifications

Midget

800V*

(10 x 38mm)
(1-1/2” x 13/32”)

3

1000V*
30A

4
4

120

-

1

USM1I-DC24

USM1I with 24VDC indicator

-

24

1

USM1I-DC1000

USM1I with 1000VDC indicator

-

1000

1

UL Recognized
CSA Certified
IEC Certified

H

* Catalog Numbers with Indicators are rated 600VAC / 600VDC unless otherwise noted.

Accessories

Description

Catalog No.
USN

1-Pole with Intergral Neutral Link

USPTH

Pin-tie Accessory for 12-Poles

US12PJMP

12-pole Jumper Bar

TBB1A

1-Phase Input Power Terminal

TBB1C

1-Phase Input Power Terminal Right Angle

USPTH Pin-Tie Accessory

Additional Specifications:

USM1 with USPTH Pin-Ties

Terminal screws: Phillips/slot head	
Suggested screw torque: 14.75 in-lbs.
Connector type: Pressure plate	
Wire range: #6 to #14 (solid/stranded Cu)
Load-break disconnect: No

Dimensions
Dimension

mm

In

Dimension

mm

In

A

17.5

0.69

G

78.0

3.07

B

35.0

1.38

H

59.0

2.32

C

52.5

2.07

I

42.5

1.67

D

70.0

2.76

J

5.0

0.20

E

78.0

3.07

K

45.0

1.77

F

2.5

0.10

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H3

USFM UltraSafe

TM

Fuse Modules

UltraSafe 3-pole fuse modules for midget and class CC fuses
Mersen UltraSafe™ Fuse Modules have a unique, compact design suited for use
with 45mm wide IEC contactors. These modules also offer other features not found
on other Class CC and midget UltraSafe fuse holders such as an auxiliary contact
option. When the auxiliary is wired to an adjacent contactor the load is dropped out
by the contactor immediately once someone tries to open the fuse extractor handle.
Additionally, the fuse module features padlock capabilities, compact busbars for
line side terminations, and tool free removal from DIN-rail. Yet the fuse modules still
incorporate well known UltraSafe features such as IP20 protection, easy operating
fuse extraction handles and an open fuse visual indication option.

Highlights:

Applications:

•• Dedicated 3-pole fuse module

•• Primarily for motor circuits to

•• Finger-safe

replace circuit breakers for higher

•• Compact footprint with

SCCR ratings
•• Other circuits up to 600 volts for

45mm width
•• Auxiliary contact option

control circuits, transformers, etc.
•• Non-load disconnect

(1NO/1NC)
•• Ability to padlock in OPEN

•• Padlock compliance

position with 1/4” shank diameter
•• DIN-rail mount with

Ratings:
USFMCC (Class CC Fuses)
Volts	

•• Quick, easy fuse change
•• Optional indicator lights

Recommended Fuse
Usage:
•• USM use with:

:

Amps	 : 30A Maximum
SCCR	 : 200kA
USFM10 (Midget 10x38mm Fuses)
Volts	

tool free removal

: 600VAC / DC	

: 600VAC / DC

Amps	 : 30A Maximum
SCCR	 : 100kA
Min. voltage to operate indicator light: 90VAC,
115VDC [Less than 0.7 mA leakage current
at 600V]

ATQ, ATM*, A6Y-2B, A25Z-2,

Approvals:

TRM, OTM, A13X-2, A60Q-2,

USFMCC (Class CC Fuses)

DCT*

•• UL Listed, guide IZLT, File
E52283

•• USCC use with:

•• CSA Certified C22.2, class 6225

ATDR, ATMR*, ATQR
* Recommended for DC applications

01, File 32169
USFM10 (Midget 10x38mm Fuses)
•• UL Recognized Component,
guide IZLT2, File E52283
•• CSA Certified C22.2, Class 6225
01, File 32169
•• IEC Certified 60269-1, 60947-3
(690VAC, 32A, 120kA)

H4

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

USFM UltraSafe

TM

Fuse Modules

Catalog Numbers and Descriptions:
For use with Class CC Fuses
Catalog No.

Description

USFMCC

3 pole fuse module

USFMCCI

3 pole fuse module with indicators

USFMCCM

3 pole fuse module with microswitch style auxiliary contact

USFMCCMI

3 pole fuse module with microswitch style auxiliary contact and indicators

USFMAC11

For use with Midget and 10x38mm UL and IEC Fuses
Catalog No.

Description

USFM10

3 pole fuse module

USFM10I

3 pole fuse module with indicators

USFM10M

3 pole fuse module with microswitch style auxiliary contact

USFM10MI

3 pole fuse module with microswitch style auxiliary contact and indicators

USFMBB2

Accessories
Description

USFMAC11

1NO (late make)/NC (early break) auxiliary contact

USFMBB2

Busbar to connect 2 modules together

USFMBB3

Busbar to connect 3 modules together

USFMBB4

Busbar to connect 4 modules together

USFMBB5

Busbar to connect 5 modules together

USFMBBC1

Busbar connector terminal

H

Catalog No.

USFMBBC1

Dimensions

Additional specifications:
Terminal screws: Pozidriv#2
Suggested screw torque: 13 Lbs-in (1.5 N-m)
Connector type: Pressure plate
Wire range: #10 to #16 AWG (1-4 mm2)
75ºC solid/stranded Cu only

Load-break disconnect: No (when auxiliary
contact is installed in fuse module and properly
wired to adjacent IEC contactor the load will be
dropped out prior to disconnection between
fuse and clip inside holder upon operation of the
fuse extractor handle).

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H5

US3J & US6J UltraSafe™ Class J Fuse Holders
UltraSafe™ modular fuse holders for class J fuses
Mersen UltraSafe Modular 600 Volt Fuse Holders for Class J fuses introduce a new
level of safety and ease for installing or replacing Class J fuses. UltraSafe holders
qualify as “finger-safe” to an IP20 grade of protection under IEC standards. The US3J
accommodates 30A Class J or 22 x 58 mm French Ferrule* fuses. The US6J is for
60A Class J fuses. UltraSafe holders are available in compact 1, 2, or 3 pole units,
with or without blown-fuse indicators in each pole. Multi-pole units can also be made
up in the field by using the multiple-pole Assembly Kits. All units have provisions for
locking in the open position for safety during fuse changeouts or equipment servicing.
US3J and US6J holders can be snap-mounted to 35 mm DIN-rail and they have a
unique latch which will stay open to allow re-positioning of the holder in the future.
UltraSafe body material is tough and durable polyamide.
*Holder not UL listed when installed with French Ferrule fuses.

Highlights

Applications:

•• Finger-safe IP20 protection

•• 600 volt motors, transformers,

•• Optional indicator lights
•• DIN-rail mount

lighting, heating, control circuits,
general loads

•• Compact footprint

•• Non-load disconnect

•• Quick, easy fuse change

Ratings:
Volts	

: 600VAC/DC

Amps	 : US3J - 30A Maximum
	

: US6J - 60A Maximum

SCCR	 : 200kA
Min. voltage to operate indicator light:
90VAC, 115VDC [Less than 0.7 mA leakage
current at 600V]

Recommended Fuse Usage:
US3J, US6J use with AJT, A4J, HSJ

Approvals:
•• UL Listed, guide IZLT File
E52283
•• CSA Certified C22.2, class 6225
01, File 32169
•• IEC certified 60269-1, 60947-3

H6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

US3J & US6J UltraSafe

TM

Class J Fuse Holders

Catalog Numbers
Catalog
No. W/O
Indicator

Voltage Rating
Catalog No.
W/ Indicator

Fuse

Description

Type

US3J1

US3J1I

1-Pole 30A Class J UltraSafe Fuse Holder

US3J2

US3J2I

2-Pole 30A Class J UltraSafe Fuse Holder

US3J3

US3J3I

3-Pole 30A Class J UltraSafe Fuse Holder

US6J1

US6J1I

1-Pole 60A Class J UltraSafe Fuse Holder

US6J2

US6J2I

2-Pole 60A Class J UltraSafe Fuse Holder

US6J3

US6J3I

3-Pole 60A Class J UltraSafe Fuse Holder

AC

DC

Ampere

No. of

Rating

Poles

Certifications

1
30A
Class J

600V

2
3

600V

1
60A

2

UL Listed
CSA Approved
IEC Certified

3

Catalog Numbers – Accessories
Accessories

Additional specifications:

Description

Catalog No.

1-Pole Neutral 30A Class J UltraSafe Fuse Holder

US3JPAK

Pin Tie Assembly Kit, 6-Poles, for use with US3J

US6JN

1-Pole Neutral 60A Class J UltraSafe Fuse Holder

US6JPAK

Pin Tie Assembly Kit, 6-Poles, for use with US6J

Terminal screws: Phillips/slot head
Suggested screw torque: 30A - 35 in-lbs. 60A - 45 in-lbs.
Connector type: Pressure plate
Wire range: #2 to #14 (solid/stranded Cu)
Load-break disconnect: No

H

US3JN

Dimensions
Dimension

US3J
mm

In

US6J
mm

In

A

32.5

1.28

40

1.57

B

65

2.56

80

3.15

C

97.5

3.84

120

4.72

E

114

4.49

122

4.80

F

3

0.12

3

0.12

G

106

4.17

115

4.53

H

80

3.15

89

3.50

I

56

2.20

62

2.44

J

6.5

0.26

6.5

0.26

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H7

US14 & US22

750 Volt UltraSafeTM Fuse Holders
UltraSafe modular fuse holders for 14 x 51 and
22 x 58mm fuses
Mersen UltraSafeTM modular 750 volt Fuse Holders offer the highest levels
of safety and features for 14 x 51 mm and 22 x 58 mm fuses. Like all UltraSafe
holders, they qualify as “finger-safe” to an IP20 grade of protection under IEC
standards, including fuse changing (with the flick of a finger). The US14 and US22
ranges are available in 1, 2 or 3 pole units, with or without blown-fuse indicator
lights in each pole.
These holders come standard with a mechanical indicator that shows fuse presence.
If a striker fuse is used, this mechanical indicator will also indicate a blown fuse.
Microswitches can be supplied with the holders (or ordered separately for field
installation) to allow remote communication. These holders also feature padlocking
capabilities, DIN-rail mounting with our unique latching system to allow re-positioning,
and the capability to be joined as multiple poles in the field.

Ratings:
Volts	

Highlights:

Applications:

•• Finger-safe

•• All circuits up to 750 volts

•• Optional indicator lights

using semiconductor fuses for

•• Optional microswitches

protection of small inverters, UPS

•• DIN-rail mount

systems, motor drives, etc.

•• Compact footprint

•• No-load disconnect

•• Quick, easy fuse change

•• IP20 requirements

: 750VAC/DC

Amps	 : 50A (14 x 51 mm)
	

: 125A (22 x 58 mm)

SCCR	 : 200kA

Recommended Fuse Usage:
•• US14 use with 14 x 51mm: A70QS, A70P, URC, URD
•• US22 use with 22 x 58 mm: A70QS, URD

Approvals:
•• All UltraSafe fuse holders
meet the requirements of
UL4248
•• UL Recognized Component
guide IZLT2, File E52283
•• CSA Certified C22.2, class
6225, File 32169
•• IEC Compliant (60269-1,
60947-3)

H8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

US14 & US22

750 Volt UltraSafeTM Fuse Holders
Catalog Numbers and Descriptions For use with 22 x 58 mm Fuses up to 125A

Catalog No.

Description

Catalog No.

Description

US141

1 Pole

US221

1 Pole

US142

2 Pole

US222

2 Pole

US143

3 Pole

US223

3 Pole

US141I

1 Pole with Indicator

US221I

1 Pole with Indicator

US142I

2 Pole with Indicators

US222I

2 Pole with Indicators

US143I

3 Pole with Indicators

US223I

3 Pole with Indicators

US141M

1 Pole with Microswitch

US221M

1 Pole with Microswitch

US142M

2 Pole with Microswitch

US222M

2 Pole with Microswitch

US143M

3 Pole with Microswitch

US223M

3 Pole with Microswitch

US143M2

3 Pole with 2 Microswitches

US223M2

3 Pole with 2 Microswitches

US141MI

1 Pole with Microswitch & Indicator

US221MI

1 Pole with Microswitch & Indicator

US142MI

2 Pole with Microswitch & Indicators

US222MI

2 Pole with Microswitch & Indicators

US143MI

3 Pole with Microswitch & Indicators

US223MI

3 Pole with Microswitch & Indicators

US143M2I

3 Pole with 2 Microswitches & Indicators

US223M2I

3 Pole with 2 Microswitches & Indicators

US141N

1 Pole - Neutral

US22N

1 Pole - Neutral

US14PAK

Accessory - Multi-pole Assembly Kit

US22PAK

Accessory - Multi-pole Assembly Kit

US14S1P

Accessory - 1 Pole Microswitch

US22S1P

Accessory - 1 Pole Microswitch

US14S3P

Accessory - 3 Pole Microswitch

US22S3P

Accessory - 3 Pole Microswitch

US14S3P2

Accessory - 3 Pole, 2 Microswitches

US22S3P2

Accessory - 3 Pole, 2 Microswitches

H

Catalog Numbers and Descriptions For use with 14 x 51 mm Fuses up to 50A

Dimensions
Dimension

US14
mm

G

US22
In

mm

In

A

26.5

1.04

35.0

1.38

B

53.0

2.09

70.0

2.76

C

79.5

3.13

105.0

4.13

E

107.0

4.21

124.0

4.88

F

3.80

0.15

3.80

0.15

G

94.0

3.70

103.0

4.06

H

76.5

3.01

76.5

3.01

I

50.5

1.98

50.5

1.98

J

6.50

0.26

6.5

0.26

K

45.0

1.77

45.0

1.77

C

H
J

B

K

E

F
I

A

Additional Specifications:
Terminal screws: Phillips/slot head
Suggested screw torque: 50A - 35 lbs.-in. 125A - 45 lbs.-in.
Connector type: Pressure Plate
Wire range: US14 #2 to #14 (solid/stranded Cu), US22 1/0 to #14 (solid/stranded Cu)
Load-break disconnect: No

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H9

US14 & US22

750 Volt UltraSafeTM Fuse Holders
Lock installation

Microswitch mounting instructions(*)

Assembly

Disassembly

Auxilliary microswitch characteristics
(*) Microswitch functions
	
Blown fuse: 	
Fuse holder containing	
Nominal current and		
	
		
fuse with striker sends 	
interrupting rating(1) at 250V		
		
message when fuse 		
					
		
blown		
						
	
Prebreaking: 	
When fuse holder opens	
Nominal current and	
		
						
interrupting rating(1) at 12 V and 24 V	
	
Presence:	
Sends message or not		
				
		
depending on fuse		
					
		
presence			
(1) According IEC947-5 Standard

H10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

6A	
3A	
0,3A	
0,1A	
6A	
5A	
2A	
0,6A	

AC12
AC13
AC14
DC12/13/14
DC12/DC13
AC13
AC14/DC13
DC14

www.barr-thorp.com

US14 & US22

750 Volt UltraSafeTM Fuse Holders
Microswitch options

H

Fuse holder assembly
US14 & US22

CLICK!

CLICK!

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H11

CLASS J 600 Volt Fuse Blocks
Mersen Class J fuse blocks accommodate all Class J fuses.
A choice of screw, pressure plate, box and special order stud connectors fit a wide
range of stranded or solid copper or aluminum conductors. Insulators are either
molded glass-filled polycarbonate (GFPC) or phenolic with verified dielectric strength
in excess of 2500V. 30A, 60A and the new 100A SJ fuse blocks feature a unique
adder block configuration which can be snapped onto 1-, 2-, or 3-pole blocks to form
multi-pole segmented blocks of as many poles as desired. All fuse clips are made
of high conductivity tin-plated copper, with a choice of spring-reinforced or nonspring reinforced clips. Space saving options are now available in the 30A and 100A
configurations which are noted in the product selection tables.

Recommended Fuse Usage:
•• Class J Blocks (600V) use with AJT, A4J, HSJ

Ratings:

Clip & Connector Types:
30A & 60A Clips
Spring Reinforced

Non-spring Reinforced

Volts	

: 600VAC / DC

Connectors

Connectors

Connectors

Connectors

Amps	 : 30A, 60A, 100A,

Non-spring Reinforced

Spring Reinforced

Spring Reinforced

Spring Reinforced

	

30A & 60A Box

30A & 60A Box

100A Box

400A Box Side Clip

SCCR:	 : 200kA

Non-spring Reinforced

Spring Reinforced 30A

Spring Reinforced

Spring Reinforced

30A Screw

Screw

100A Box Side Clip

400A Box In-line Clip

Non-spring Reinforced

Spring Reinforced 30A

Spring Reinforced

Spring Reinforced

30A Pressure Plate

Pressure Plate

200A Box Side Clip

600A Box In-line Clip

: 200A, 400A, 600A

Approvals:
•• All class J fuse blocks meet
the requirements of UL4248
(formerly UL512)
•• UL listed Guide IZLT, File
E52283
•• CSA certified class 6225,
File 32169

H12

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

CLASS J 600 Volt Fuse Blocks
600 Volt, 30 & 60 Ampere Class J Fuse Blocks
Rating

Connectors
Poles

Types

Catalog Number

Wire

Non-Spring

Spring

Range

Reinforced

Reinforced

60300J

60305SJ

Al/Cu

60301J

60306SJ

#2-14

60302J

60307SJ

3

60303J

60308SJ

ADDER

60310J

60315SJ

Cu*

60311J

60316SJ

#4-14

60312J

60317SJ

60313J

60318SJ

ADDER
1
2

1
2

30
GFPC
Insulator

BOX

SCREW

3
ADDER

60320J

60325SJ

1

PRESSURE

Cu*

60321J

60326SJ

2

PLATE

#4-14

60322J

60327SJ

60323J

60328SJ

3

-

60355SJ

Cu*

-

60356SJ

#4-14

-

60357SJ

-

60358SJ

ADDER
1
2

BOX

3

60600J

60605J

Al/Cu

60601J

60606J

#2-14

60602J

60607J

60603J

60608J

-

60655J

Cu*

-

60656J

#4-14

-

60657J

-

60658J

ADDER
1
2

60
GFPC
Insulator

BOX

3
ADDER
1
2

BOX

3

1-Pole

2-Pole

Torque
In - lb

35

20

20

35

45

45

Note: To convert 30A “SJ” adder pole to single pole use
end barrier cat # U09372. To convert 30A or 60A standard J
adder pole to single use pole use end barrier cat # U09617.
Recommended mounting screws for all 30A and 60A fuse
blocks: 1/4” (0.250” dia).
*Fuses have copper box connectors and clips and are for
copper wires only. These are specifically designed with the
same coefficient of expansion as copper wire for improved
heat cycling and meet or exceed OEM “no aluminum”
specifications.

Dimensions for 30A and 60A Standard
Class J Style Fuse Blocks

Dimensions for 30A Space Saving
“SJ” Style Fuse Blocks

Adder

Connector

H

Ampere

3-Pole

Adder

1-Pole

2-Pole

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

3-Pole

H13

CLASS J 600 Volt Fuse Blocks
600 Volt, 200, 400 & 600 Ampere Class J Fuse Blocks
Connectors

Ampere

Poles

Rating

1

Box

Al/Cu

61006SJ

100 (Al)

2

Side Clip

2/0-#6

61007SJ

60 (Cu)

61005SJ

61008SJ

1
2

Insulator

Torque In - lb

Wire Range

3

GFCP

Box

3
1
2

Spring Reinforced

Connector

Type

Adder

100

Catalog Number

Box

3

Al/Cu
2/0-#6

61036J
61037J

120

61038J
61006J

Cu*
2/0-#12

61007J

50

61008J

Dimensions for 100A Space Saving “SJ” Style Fuse Blocks

Adder

2-Pole

1-Pole

3-Pole

Dimensions for 100A Standard Class J Style Fuse Blocks

1-Pole

H14

2-Pole

3-Pole

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

CLASS J 600 Volt Fuse Blocks
600 Volt, 200, 400 & 600 Ampere Class J Fuse Blocks
Ampere
Rating
200
Phenolic
Insulator

400
Phenolic
Insulator

600
Phenolic

Type

Wire Range

Catalog No.
Spring

Fig.

Reinforced

1

Box

Al/Cu

62001J

1

3

Side-Clip

350kcmil-#6

62003J

2

1

Box

Cu**

62051J

1

3

Side-Clip

350kcmil-#6

62053J

2

1

Box*

AL/Cu

64001J

3

3

Side-Clip

1000-250kcmil

64003J

4

1

Box

AL/Cu

64031J

5

3

In-Line Clip

(2) 350kcmil-#4

64033J

6

1

Box*

Cu**

64051J

3

3

Side-Clip

1000-250kcmil

64053J

4

1

Box

Cu**

64061J

5

3

In-Line Clip

(2) 350kcmil-#6

64063J

6

1

Box

Al/Cu

6631J

7

3

In-Line Clip

(2) 500kcmil-#4

6633J

8

1

Box

Cu**

6661J

7

3

In-Line Clip

(2) 500kcmil-#4

6663J

8

Connector
Torque In - lb
375
275
375

*	 Not UL Listed or CSA
Certified

275

**	 Fuse blocks have copper
box connectors and clips
and are for copper wires
only. These are specifically
designed with the same coefficient of expansion as copper
wire for improved heat cycling
and meet or exceed OEM “no
aluminum” specifications.

375
275
500
375

Recommended mounting
screws:
All 200A, 400A & 600A 5/16” (.313” dia.)

H

Insulator

Connector
Poles

Dimensions

Figure 1

Figure 5

Figure 2

Figure 3

Figure 4

Figure 6
Figure 7

Figure 8

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H15

MIDGET & CLASS CC

600 Volt Fuse Blocks

600 Volt midget and Class CC fuse blocks
Mersen midget fuse blocks accommodate all 30 ampere 1-1/2” x 13/32” midget fuses.
Class CC fuse blocks accommodate all 30 ampere Class CC fuses. A choice of box,
screw, or pressure-plate connectors fit a wide range of stranded or solid copper wire.
Insulators are glass-filled polycarbonate (GFPC) with verified dielectric strength in
excess of 2500V. Fuse blocks feature a unique adder block which can be snapped
onto 1-, 2- or 3-pole blocks to form multi-pole segmented blocks of as many poles as
desired. All fuse clips are made of high conductivity tin-plated copper alloy.

Recommended Fuse Usage:
Midget Fuse Block use with ATQ, ATM, A6Y-2B, A25Z-2,
TRM, OTM, A15QS-2, GFN, GGU, A60Q-2, DCT

Ratings:

Class CC Fuse Block use with ATDR, ATMR, ATQR

Clip & Connector Types
30A MIDGET/CC
COPPER BOX

SCREW WITH DOUBLE

PRESSURE PLATE

PRESSURE PLATE WITH

CONNECTOR

QUICK-CONNECTS

WITH DOUBLE QUICK-

DOUBLE QUICK- CONNECTS

CONNECTS

(CLASS CC REJECTION END)

Midget Block
Volts	 : 600VAC / DC
Amps	 : 30A Maximum
SCCR	 : 100kA (depending on 	
	
fuse I.R.)
	
: 10kA (when using quick 	
	
connect terminal)
Class CC Block
Volts	 : 600VAC / DC
Amps	 : 30A Maximum
SCCR	 : 200kA
	
: 10kA (when using quick 	
	
connect terminal)
Temperature/flammability GFPC
insulators rated 1250C, 94V-0
flammability.

Approvals:
All fuse blocks meet the
requirements of UL 4248
Midget Block
•• UL recognized component
guide IZLT2, File E52283
•• CSA certified class 6225,
File 32169		
Class CC Block
•• UL listed, guide IZLT, File
E52283
•• CSA certified class 6225,
File 32169

H16

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

MIDGET & CLASS CC

600 Volt Fuse Blocks

600 Volt, 30A Midget and Class CC Fuse Blocks
Connector
Type

Catalog No.

Wire Range

Screw w/
double quick

Cu

connects at

#10-14

both ends

Poles*

Midget

Listing

Class CC

Torque
Listing

30310R

ADDER

30310

1

30311

UL Rec.

30311R

UL

2

30312

&

30312R

&

3

30313

CSA

30313R

CSA

4

30314

Pressure plate

ADDER

30320

(sems) w/

1

30321

UL Rec.

30321R

UL

2

30322

&

30322R

&

3

30323

CSA

30323R

CSA

4

30324

30324R

ADDER

30350

30350R

1

30351

UL Rec.

30351R

UL

2

30352

&

30352R

&

3

30353

CSA

30353R

CSA

4

30354

double quick
connects at

Cu
#10-14

both ends

Copper box

Cu
#6-14

In - Ib

20

30314R
30320R
20

35

30354R

Note: To convert Midget or Class CC adder pole to single pole, use end barrier #U09301.

H

* Available in any number of poles. Replace last digit in Catalog Number with number of poles needed.
Example: 303112 is a 12-pole screw/double QC connector Midget Fuse Block. Total width of N poles = (N x .76) + .08
inches. 12 poles = (12 x .76”) + .08” = 9.20”.

Recommended mounting screws for all Midget and Class CC fuse blocks: #8 (.164” dia.)

Dimensions

Adder

1 Pole

2 Pole

3 Pole

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H17

CLASS H, K & R

250 & 600 Volt Fuse Blocks
250 & 600V Class H, K & R Fuse Blocks
Mersen Class H, K and R fuse blocks accommodate all Class H, K and R 250
and 600V power fuses. A choice of screw, pressure plate, box and special order
stud connectors fit a wide range of stranded or solid copper or aluminum wire.
Insulators are either molded glass-filled polycarbonate (GFPC) or phenolic with
verified dielectric strength in excess of 2500V. 30, 60 and 100A fuse blocks feature
a unique adder block which can be snapped onto 1-, 2- or 3-pole blocks to form
multi-pole segmented blocks of as many poles as desired. All fuse clips are made of
high conductivity tin-plated copper, with a choice of spring reinforced or non-spring
reinforced clips in 30A and 60A. Clips 100A and above are spring reinforced.

Recommended Fuse Usage:
Class R Blocks (250V) use with A2D-R, A2K-R, TR-R
Class R Blocks (600V) use with A6D-R, A6K-R, TRS-R
Class H & K Blocks (250V) use with OT, RF, A2Y types 1 & 3 OTN, CRN, NRN
Class H & K Blocks (600V) use with OTS, RFS, A6Y types 1 & 3 CRS, NRS

Clip & Connector Types

Ratings:
Volts	

: 250VAC / DC

	

: 600VAC /DC	

Amps	 : 30A, 60A, 100A, 200A, 	

30A & 60A Clips

Connectors

Connectors

Spring Reinforced

Non-Spring Reinforced

Spring Reinforced

Class R

30A & 60A Box

30A & 60A Box

Class H & K

Non-Spring

Spring

30A Screw

30A Screw (R)

Non-Spring

Non-Spring

Spring

Reinforced

30A Pressure Plate

30A Screw

	

400A, 600A

SCCR:	 : 10kA with class H fuses
	

: 50kA with class K fuses

	

: 200kA with class R fuses

Approvals:
•• All fuse blocks meet the
requirements of UL 4248

Spring Reinforced
30A Pressure Plate

•• UL listed, guide IZLT,
File E52283
•• UL recognized component
guide IZLT2, file E52283

Connectors
Spring

Spring Reinforced

Reinforced

400A Box

100A Box

In-Line Clip

Spring

Spring 400A Box

200A Box

Side Clip

•• CSA certified class 6225,
File 32169

Side Clip

H18

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

CLASS H, K & R 250 & 600 Volt Fuse Blocks
250 Volt, 30 & 60 Ampere Class H, K and R Fuse Blocks

Rating

Poles

Type

Wire Range

ADDER
1

Class R

Spring Reinforced

Spring einforced

Spring Reinforced

20305

20305R

1

20301*

20306*

20306R*

2

20302

20307

20307R

3

20303

20308

20308R

4
1

20310

20315

20315R

Cu

20311*

20316*

20316R*

2

#10-14

20312

20317

20317R

3

3

20313

20318

20318R

4

ADDER

20320

20325

20325R

1

1

SCREW

2

1

PRESSURE

Cu

20321*

20326*

20326R*

2

2

PLATE

#10-14

20322

20327

20327R

3

3

20323

20328

20328R

4

ADDER

-

20355

20355R

1

1

Cu**

-

20356*

20356R*

2

#4-14

BOX

2

-

20357

20357R

3

3

-

20358

20358R

4

ADDER

20600

20605

20605R

5

Al/Cu

20601

20606

20606R

6

#2-14

20602

20607

20607R

7

20603

20608

20608R

8
5

1

BOX

2
60 GFPC

3

Insulator

ADDER
1

BOX

2

-

20655

20655R

Cu**

-

20656

20656R

6

#4-14

-

20657

20657R

7

-

20658

20658R

8

3

Torque
In - Ib

#2-14

ADDER

Insulator

Class H  K

Al/Cu

3

30 GFPC

Connector
Fig.

Class H & K Non-

20300
BOX

2

Catalog No.

35

20

20

35

H

Connector
Ampere

45

45

Note: To convert 30A adder pole to single pole, use end barrier #U09322. To convert 60A adder pole to single pole, use end barrier #U09365.
*	 1-pole, 30A block does not accept adder pole.
**	 Fuse blocks have copper box connectors and clips and are for copper wires only. These are specifically designed with the same coefficient of expansion as copper wire for improved heat cycling and meet or exceed OEM “no aluminum” specifications.

Recommended mounting screws for all 30A and 60A fuse blocks: #10 (.190” dia.)

Dimensions

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

Figure 7

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Figure 8

H19

CLASS H, K & R 250 & 600 Volt Fuse Blocks
250 Volt, 100 & 200 Ampere Class H, K and R Fuse Blocks
Connector
Ampere
Rating

Poles

Type

Wire Range

21036

21036R

2

21037

21037R

3

3

21038

21038R

4

ADDER

21005

21005R

1

Cu*

21006

21006R

2

2/0-#12

21007

21007R

3

21008

21008R

4

Box

3

Insulator

Torque
In - Ib

2/0-#6

Box

2

Phenolic

Reinforced
1

1

200

Spring Reinforced

Connector
Fig.

21035R

2

Insulator

Class R Spring

21035

1

GFPC

Class H & K 

Al/Cu

ADDER

100

Catalog No.

1

Box Side-

AL/Cu

22001

22001R

5

3

Clip

350kcmil-#6

22003

22003R

6

1

Box Side-

Cu*

22051

22051R

5

3

Clip

350kcmil-#6

22053

22053R

6

120

50

375

275

Note: To convert 100A adder pole to single pole, use end barrier #U09363.
*Fuse blocks have copper box connectors and clips and are for copper wires only. These are specifically designed with the same coefficient of expansion as
copper wire for improved heat cycling and meet or exceed OEM “no aluminum” specifications.
Recommended mounting screws:
	
All 100A-1/4” (.250” dia.)
	
200A, 1-pole - #10 (.190” dia.)
	
200A, 3-pole - 5/16” (.313” dia.)

Dimensions

Figure 1

H20

Figure 2

Figure 5

Figure 3

Figure 4

Figure 6
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

CLASS H, K & R 250 & 600 Volt Fuse Blocks
250 Volt, 400 & 600 Ampere Class H, K and R Fuse Blocks
Connector
Ampere
Rating

400
Phenolic
Insulator

600
Phenolic
Insulator

Poles

Type

Wire Range

Catalog No.

Connector

Class H & K 

Class R

Spring Rein-

Spring

forced

Reinforced

Fig.

Torque
In - Ib

1

Box*

Al/Cu

24001

24001R

1

3

Side-Clip

1000-250kcmil

24003

24003R

2

1

Box*

Cu**

24051

24051R

1

3

Side-Clip

1000-250kcmil

24053

24053R

2

1

Box

Al/Cu

24031

24031R

3

3

In-Line Clip

(2) 350kcmil-#4

24033

24033R

4

1

Box

Al/Cu

24061

24061R

3

3

In-Line Clip

(2) 350kcmil-#6

24033

24033R

4

1

Box

Al/Cu

2631

2631R

5

3

In-Line Clip

(2) 500kcmil-#4

2633

2633R

6

1

Box

Cu**

2661

2661R

5

3

In-Line Clip

(2) 500kcmil-#4

2663

2663R

6

375

375

275
275
500
375

H

*Not UL Listed or CSA Certified
**Fuse blocks have copper box connectors and clips and are for copper wires only. These are specifically designed with the 		
same coefficient of expansion as copper wire for improved heat cycling and meet or exceed OEM “no aluminum” specifications.
Recommended mounting screws for all 400A and 600A fuse blocks: 5/16 (.313” dia.)

Dimensions

Figure 2

Figure 1

Figure 5

Figure 3

Figure 4

Figure 6

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H21

CLASS H, K & R 250 & 600 Volt Fuse Blocks
600 Volt, 30 & 60 Ampere Class H, K and R Fuse Blocks
Connector

Catalog No.

Ampere
Rating

Poles

60300

60305

60305R

1

60301

60306

60306R

2

#2-14

60302

60307

60307R

3

60303

60308

60308R

4

60315

60315R

1

60311

60316

60316R

2

#10-14

60312

60317

60317R

3

3

60313

60318

60318R

4

ADDER

60320

60325

60325R

1

60321

60326

60326R

2

Screw

2

1

Pressure

Cu

2

Plate

#10-14

60322

60327

60327R

3

3

60323

60328

60328R

4

ADDER

-

60355

60355R

1

Cu*

-

60356

60356R

2

#4-14

-

60357

60357R

3

3

-

60358

60358R

4

ADDER

60600

60605

60605R

1

Al/Cu

60601

60606

60606R

2

#2-14

60602

60607

60607R

3

3

60603

60608

60608R

4

ADDER

-

60655

60655R

1

Cu*

-

60656

60656R

2

#4-14

-

60657

60657R

3

-

60658

60658R

4

Box

2

1

Insulator

Box

2

1
2

Box

3

Torque
In - Ib

60310

1

GFPC

Spring Reinforced

Cu

1

60

Spring Reinforced

Al/Cu

ADDER

Insulator

Spring Reinforced

Fig.

Box

3

GFPC

Class R

Wire Range

2

30

Class H & K 

Type

ADDER
1

Connector

Class H & K  Non-

35

20

20

35

45

45

Note: To convert 30A or 60A adder pole to single pole, use end barrier #U09361.
* Fuse blocks have copper box connectors and clips and are for copper wires only. These are specifically designed with the same coefficient of expansion 	
as copper wire for improved heat cycling and meet or exceed OEM “no aluminum” specifications.
Recommended mounting screws for all 30A and 60A fuse blocks: 1/4” (.250” dia.)

Dimensions

Figure 1

H22

Figure 2

Figure 3

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Figure 4

www.barr-thorp.com

CLASS H, K & R 250 & 600 Volt Fuse Blocks
600 Volt, 100 & 200 Ampere Class H, K and R Fuse Blocks
Connector
Ampere
Rating

Poles

Type

ADDER
1
100

3

Insulator

ADDER

Box

1

Box

3

Wire Range

Al/Cu
2/0-#6
Cu*
2/0-#12

Catalog No.
Class H & K 

Class R

Spring Rein-

Spring

forced

Reinforced

Connector
Fig.

Torque
In - Ib

61035

61035R

1

61036

61036R

2

61038

61038R

3

61005

61005R

1

61006

61006R

2

61008

61008R

3

1

Box

Al/Cu

62001

62001R

4

200

3

Side-Clip

350kcmil-#6

62003

62003R

5

Insulator

1

Box

Cu*

62051

62051R

4

3

Side-Clip

350kcmil-#6

62053

62053R

5

120

50

375
275

* Fuse blocks have copper box connectors and clips and are for copper wires only. These are specifically designed with the same coefficient of expansion
as copper wire for improved heat cycling and meet or exceed OEM “no aluminum” specifications.

H

Recommended mounting screws:
	
All 100A-1/4” (.250” dia.)
	
200A, 1-pole - #10 (.190” dia.)
	
200A, 3-pole - 5/16” (.313” dia.)

Dimensions

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H23

CLASS H, K & R 250 & 600 Volt Fuse Blocks
600 Volt, 400 & 600 Ampere Class H, K and R Fuse Blocks
Connector

Ampere
Rating

400
Phenolic
Insulator

600
Phenolic
Insulator

Catalog No.

Connector
Fig.

Class H & K 

Class R

Spring Reinforced

Spring Reinforced

Poles

Type

Wire Range

1

Box*

Al/Cu

64001

64001R

1

3

Side-Clip

1000-250kcmil

64003

64003R

2

1

Box*

Cu**

64051

64051R

1

3

Side-Clip

1000-250kcmil

64053

64053R

2

1

Box

AL/Cu

64031

64031R

3

3

In-Line Clip

(2) 350kcmil-#4

64033

64033R

4

1

Box

Cu**

64061

64061R

3

3

In-Line Clip

(2) 350kcmil-#6

64063

64063R

4

1

Box

Al/Cu

6631

6631R

5

3

In-Line Clip

(2) 500kcmil-#4

6633

6633R

6

1

Box

Cu**

6661

6661R

5

3

In-Line Clip

(2) 500kcmil-#4

6663

6663R

6

Torque
In - Ib

375
375
275
275
500
375

*Not UL Listed or CSA Certified
**Fuse blocks have copper box connectors and clips and are for copper wires only. These are specifically designed with the same coefficient of expansion as copper wire
for improved heat cycling and meet or exceed OEM “no aluminum” specifications.
Recommended mounting screws for all 400A and 600A fuse blocks: 5/16 (.313” dia.)

Dimensions

Figure 1

Figure 2

Figure 5

H24

Figure 3

Figure 4

Figure 6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

CLASS T 300 & 600 Volt Fuse Blocks
300 & 600V Class T Fuse Blocks
Mersen Class T fuse blocks accommodate Class T fuses up to 600A. Insulators are
either durable, glass-filled polycarbonate (GFPC) or phenolic with verified dielectric
strength in excess of 2500V. Mersen is the only manufacturer to offer Class T blocks
with copper connectors.

Features/Benefits:
•• Unique integral DIN-rail adapters for 600V, 30 & 60A blocks
•• Full barrier design (30 & 60A) increases pole to pole safety
•• Unique adder-block design (30 & 60A) for design flexibility
•• Spring reinforcing standard for all 30 & 60A clips
•• Features high conductivity copper alloy fuse clips
•• Cool running high amperage (100 - 600A) connectors
•• Copper connectors available 30 - 600A

Ratings:

Recommended Fuse Usage:
Class T Blocks (300V) use with A3T
Class T Blocks (600V) use with A6T

Volts	

: 300VAC / DC

	

: 600VAC / DC	

	

Clip & Connector Types
Spring Reinforced

Connectors for Spring

30A & 60A Clips

Reinforced 30A & 60A Clips

300V - 30A

400A, 600A

SCCR:	 : 200kA
Connectors

Connectors

30A - 60A

100A Box

400A Box

600V - 30A

Box

Side Clip

300V - 60A

30A - 60A

100A Box

Screw

H

Amps	 : 30A, 60A, 100A, 200A, 	

600A
Box

Approvals:
•• All fuse blocks meet the

600V - 60A

30A - 60A

200A Box

Pressure
Plate

requirements of UL 4248
•• UL listed, guide IZLT,
File E52283
•• UL recognized component guide
IZLT2, file E52283
•• CSA certified class 6225,
File 32169

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H25

CLASS T 300 & 600 Volt Fuse Blocks
300 Volt, 30 & 60 Ampere Class T Fuse Blocks
Ampere
Rating

30
GFPC
Insulator

60
GFPC
Insulator

Connector
Poles
ADDER
1
2
3
4
ADDER
1
2
3
4
ADDER
1
2
3
4
ADDER
1
2
3
4
ADDER
1
2
3
4
ADDER
1
2
3

Type

Wire Range

Catalog No.
Spring Reinforced

Fig.

30305T
30306T
30307T
30308T
30309T
30315T
30316T
30317T
30318T
30319T
30325T
30326T
30327T
30328T
30329T
30355T
30356T
30357T
30358T
30359T
30615T**
30616T**
30617T**
30618T**
30619T**
30605T
30606T
30607T
30608T

1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4

4

30609T

5

ADDER
1
2
3
4

30655T
30656T
30657T
30658T
30659T

1
2
3
4
5

Box

Al/Cu
#2-14

Screw

Cu
#10-14

Pressure
Plate

Cu
#10-14

Box

Cu*
#4-14

Screw

Cu
#10-14

Box

Al/Cu
#2-14

Box

Cu*
#4-14

Connector
Torque In - Ib

35

20

20

35

20

45

45

*Fuse blocks have copper box connectors and clips and are for copper wires only. These are specifically designed with the same coefficient of
expansion as copper wire for improved heat cycling and meet or exceed OEM “no aluminum” specifications.
** UL Component Recognized
Recommended base mounting screws: #10 (.190” dia.)

Dimensions

Figure 1

H26

Figure 2

Figure 3

Figure 4

Figure 5

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

CLASS T 300 & 600 Volt Fuse Blocks
300 Volt, 100, 200, 400 & 600 Ampere Class T Fuse Blocks
Ampere
Rating

Connector
Poles
Type

100

1

Phenolic

2

Insulator

3

200
Phenolic
Insulator
400
Phenolic
Insulator
600
Phenolic
Insulator

Catalog No.

1

Wire Range

Box
Box

3
1

Box

3
1

Box

3
1

Box

3
1

Box

Connector Torque In - Ib
Fig.

Spring

Connector

Reinforced

Cu*

31001T

1

2/0-#12

31002T

2

31003T

3

Al/Cu

32031T

4

350 kcmil-#6

32033T

5

Cu*

32051T

4

350 kcmil-#6

32053T

5

Al/Cu

34031T

6

600 kcmil-#2

34033T

7

Cu*

34051T

6

600 kcmil-#2

34053T

7

Al/Cu

36031T
36051T

Fuse
Bolt

50

72

275

132

275

132

600

228

375

228

8

600

360

8

375

360

(2) 600 kcmil-#2
1

Box

Cu*
(2) 600 kcmil-#2

† Note: Height includes nominal fuse blade
thickness
Recommended base mounting screws:
100A & 200A, #10 (.190” dia.)
400A & 600A, 1/4” (.250” dia.)

Note: * Fuse blocks have copper box
connectors and are for copper wires only.
These are specifically designed with the same
coefficient of expansion as copper wire for
improved heat cycling and meet or exceed
OEM “no aluminum” specifications.

Figure 1

Figure 4

H

Dimensions

Figure 2

Figure 5

Figure 3

Figure 6

Figure 7

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Figure 8

H27

CLASS T 300 & 600 Volt Fuse Blocks
600 Volt, 30 & 60 Ampere Class T Fuse Blocks
Ampere
Rating

Poles

Connector
Type

ADDER
1

Box

2

30
GFPC
Insulator

2

Al/Cu

60306T

2

#2-14

60307T

3

60308T

4

60315T

1

Cu

60316T

2

#10-14

60317T

3

60318T

4

3
ADDER

60325T

1

1

Pressure

Cu

60326T

2

2

Plate

#10-14

60327T

3

60328T

4

3
ADDER
1

Box

2

60355T

1

Cu*

60356T

2

#4-14

60357T

3

60358T

4

3
ADDER
1

Screw

2

60615T**

5

Cu

60616T**

6

#10-14

60617T**

7

60618T**

8

3
60
GFPC
Insulator

Fig.

1

ADDER
Screw

Spring Reinforced

60305T

3
1

Catalog No.

Wire Range

ADDER
1

Box

2

60605T

5

Al/Cu

60606T

6

#2-14

60607T

7

60608T

8

3
ADDER
1
2

Box

60655T

5

Cu*

60656T

6

#4-14

60657T

7

60658T

8

3

Connector
Torque In - Ib

35

20

20

35

20

45

45

*Fuse blocks have copper box connectors and
clips and are for copper wires only. These are
specifically designed with the same coefficient
of expansion as copper wire for improved
heat cycling and meet or exceed OEM “no
aluminum” specifications.
** UL Component Recognized

Recommended mounting screws:
30A, #10 (.190” dia.)
60A, 1/4 “ (.250” dia.)

Dimensions

Figure 1

H28

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Figure 7

www.barr-thorp.com

Figure 8

CLASS T 300 & 600 Volt Fuse Blocks
600 Volt, 100, 200, 400 & 600 Ampere Class T Fuse Blocks
Ampere
Rating

Connector
Poles

Type

1
100
Phenolic
Insulator

2

BOX

3
1
2

BOX

3
200
Phenolic

1
1

Insulator

3

400

1

Phenolic
Insulator
600
Phenolic
Insulator

BOX

3
BOX
BOX

Wire Range

Al/Cu
2/0-#6

Catalog No.
Spring

Torque (In - Lbs)
Fig.

Reinforced

61031T

1

61032T

2

61033T

3

61051T

1

61052T

2

61053T

3

Al/Cu

62031T

4

350 kcmil-#6

62033T

5

Cu*
2/0-#12

Connector

Fuse Bolt

120

72

50

72

275

132

275

132

Cu*

62051T

4

350 kcmil-#6

62053T

5

Al/Cu

64031T

6

600

228

64051T

6

375

228

66031T

7

600

360

66051T

7

375

360

600 kcmil-#2
1

BOX

Cu*
600 kcmil-#2

1

BOX

Al/Cu
(2) 600 kcmil-#2

1

BOX

Cu*
(2) 600 kcmil-#2

Note: Fuse blocks have copper box
connectors and are for copper wires only.
These are specifically designed with the
same coefficient of expansion as copper
wire for improved heat cycling and meet
or exceed OEM “no aluminum” specifications.

Recommended base mounting screws:
100A & 200A, #10 (.190” dia.)
400A & 600A, 1/4 “ (.250” dia.)

H

Dimensions

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

† Note: Height includes nominal fuse blade thickness

Figure 6

Figure 7

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H29

CLASS G 480 & 600 Volt Fuse Blocks
480 & 600V Class G Fuse Blocks
Mersen Class G fuse blocks accommodate all 15, 20, 30 and 60 ampere Class
G fuses. A choice of box, screw or pressure-plate connectors fit a wide range of
stranded or solid copper wire. Insulators are glass-filled polycarbonate (GFPC)
with verified dielectric strength in excess of 2500V. Fuse blocks feature a unique
adder block which can be snapped onto 1-, 2-, or 3-pole blocks to form multi-pole
segmented blocks of as many poles as desired. All fuse clips are made of high
conductivity tin-plated copper alloy.

Features/Benefits:
•• Unique integral DIN-rail adapters for 15, 20 & 30A blocks
•• Unique adder-block design (all ampere ratings) for design flexibility
•• Spring reinforcing standard for 60A clips
•• Features high conductivity copper alloy fuse clips

Ratings:

Recommended Fuse Usage:
Class G Blocks use with AG

Volts	

: 600VAC (15, 20A)

	

: 480VAC (30, 60A)

Amps	 : 15A, 20A, 30A, 60A
SCCR:	 : 100kA
	

Clip & Connector Types

	

: 10kA (when using quick 	
connects)

15, 20, 30, 60A

15, 20, 30A

15, 20, 30A

COPPER BOX CONNECTOR OR

SCREW WITH DOUBLE QUICK-

PRESSURE PLATE WITH DOUBLE-

Temperature/Flammability:

ALUMINUM BOX

CONNECTS

QUICK CONNECTS

GFPC insulators rated 1250C RTI,
94V-0 flammability

CONNECTOR

Approvals:
All fuse blocks meet the
requirements of UL 4248
•• UL Listed guide IZLT,
File E52283
•• CSA Certified class 6225,
File 32169

H30

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

CLASS G 480 & 600 Volt Fuse Blocks
600 Volt, 15 & 20 Ampere; 480 Volt 30 & 60 Ampere Class G Fuse Blocks
Rating

Connector

Poles

Type

ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3
ADDER
1
2
3

15
GFPC
Insulator

20
GFPC
Insulator

30
GFPC
Insulator

60
GFPC
Insulator

Wire Range

Screw w Double
Quick Connects at
Both Ends
Pressure Plate
(SEMS) w Double
Quick Connects at
Both Ends
Screw w Double
Quick Connects at
Both Ends
Pressure Plate
(SEMS) w Double
Quick Connects at
Both Ends
Screw w Double
Quick Connects at
Both Ends

Cu
#10-14

Cu
#10-14

Cu
#10-14

Cu
#10-14

Cu
#10-14

Pressure Plate
(SEMS) w Double
Quick Connects at
Both Ends

Cu
#10-14

Copper
Box

Cu
#6-14

Aluminum
Box

Al/Cu
#2-14

Copper
Box

Cu
#4-14

Catalog No.

Fig.

40110G
40111G
40112G
40113G
40120G
40121G
40122G
40123G
40210G
40211G
40212G
40213G
40220G
40221G
40222G
40223G
40310G
40311G
40312G
40313G
40320G
40321G
40322G
40323G
40350G
40351G
40352G
40353G
40605G
40606G
40607G
40608G
40655G
40656G
40657G
40658G

1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
5
6
7
8
5
6
7
8

Torque
(In - Lbs)

20

20

20

20

20

20

H

Ampere

35

45

45

Dimensions
.17x.10 DP

.17x.10 DP

3.05
1.53
.17
.34
1.45

3.78
1.89
.25
.77

.85

1.11
1.62

1.88
2.39

.76
1.40

.64

Figure 1

.16

Figure 2

Figure 3

Figure 4

.35

.26
.86

1.11
1.62

1.87
2.38

.52

Figure 5

Figure 6 Figure 7

Figure 8

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H31

Miniature Fuse Blocks
5X20QC1 & 6X32QC1 Single Pole Fuse Blocks
The 5X20QC1 single pole fuse blocks are for for 5mm x 20mm fuses featuring tinplated clips, a polyester insultator and 3/16” quick-connect terminals. The 6X32QC1
single pole fuse blocks are for 1/4” x 1-1/4” fuses and have tin-plated phosphor
bronze clips, a phenolic insulator and 1/4” quick-connect terminals.

Features/Benefits:
5X20QC1

6X32QC1

Single Pole Fuse Block

Single Pole Fuse Block for

for 5mm x 20mm fuses

1/4” x 1-1/4” fuses

•• Tin plated clips

•• Tin plated phosphor bronze clips

•• Polyester insulator

•• Phenolic insulator

•• 3/16” quick-connect terminals

•• 1/4” quick-connect terminals

•• Rated 15A, 250V

•• Rated 30A, 250V - UL Recognized

•• UL recognized

Ratings:
5X20QC1:

Recommended Fuse Usage:

Volts:	 250V

5X20QC1 use with GGM, GGA, GSA, GSB, GDG

Amps	 : 15A

6X32QC1 use with GSA, GDL, GGC, GAB
6X32QC1:
Volts:	 250V

Dimensions:

Amps	 : 30A

Approvals:
•• UL Recognized	
	5X20QC1

	6X32QC1

H32

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

FEB,FEC,FEX,FEY

600 Volt In-Line Fuse Holders
Mersen’s complete line of single and dual pole in-line fuse holders accommodate
either 1-1/2” x 13/32” (10x38mm) midget or Class CC fuses. The fuse holders are
designed for quick installation. Securing nuts or screws are captive thus speeding
installation by reducing the need to locate and assemble loose components in the
field. Three internal O-rings per pole seal the fuse holder providing a water-resistant
compartment for the fuse. The captive O-rings are colored (blue for single pole and
red for dual pole) for quick detection. Optional cone shaped insulator boots can
be slipped on to provide a watertight seal (breakaway versions come with boots
standard). Both single and dual pole versions have an optional breakaway feature
which safely disconnects the load in case of a pole knockdown. Fuses remain safely
encapsulated within the watertight fuse holder on the load side. Once the pole has
been reinstalled the fuse holder can be easily reconnected.

Applications:
•• Street lighting
•• Parking lot lighting
•• Traffic signaling

Ratings:
Volts:	 : 600VAC / DC
Amps	 : 30A Maximum

•• Boats and marinas
•• Humid/corrosive environments

SCCR	 : 200kA (Class CC Fuses)
	

: 100kA (Midget Fuses)

H

•• Sports lighting

Temperature Rating 155º C

Highlights:
•• Breakaway version quickly disconnects line side during pole knockdown in
compliance with state and federal highway commission standards
•• 3 O-rings per pole for water tight applications
•• Colored O-rings for quick detection
•• Single and dual poles
•• Accepts midget or Class CC fuses
•• Wide assortment of terminal variations

Approvals:

•• High heat, impact resistant insulator

•• UL Listed Class CC Guide IZLT,

•• Captive nut or screw for quick installations
•• Polarized dual pole provides simultaneous disconnection

File E52283
•• UL Recognized Component

•• Permanently installed neutral versions quickly identified by white nuts

Midget Guide IZLT2,

•• Tulip fuse clip for improved contact and low losses

File E52283

•• Environmentally friendly-no lead solder used
•• Highly visible catalog number even with insulation boots installed

•• CSA Certified Class CC and
Midget Class 6225, File 32169

•• Wire gauge size identified on insulation boots for quick, accurate trimming
•• Time delay for motor starting and transformer inrush

Recommended Fuse Usage:
FEB and FEX holders use with:
Midget (1-1/2” x 13/32”, 10 x 38mm): ATQ, ATM, TRM, OTM, GGU, GFN,
A13X-2, A25Z-2, A60Q-2, A6Y-2B
FEC and FEY holders use with:
Class CC: ATDR, ATMR, ATQR

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H33

FEB,FEC,FEX,FEY 600 Volt In-Line Fuse Holders
Catalog Numbering System
Family
FEB-

Load Terminal
1

1

Line Terminal

Option

1

-BA

1

Nomenclature Legend
Family

Load or Line Terminal Type

Description
Terminal End View

FEB

Single pole midget

FEC

Single pole Class CC

FEX

Dual Pole midget

FEY
FEBN

Dual pole Class CC

Terminal

Type

11

Cu Crimp

21

Cu Crimp

Single pole neutral
31

Cu Crimp

Wire

Option
No. Per

Solid

Stranded

#8-#12

1

Yes

Yes

#12-#14

2

Yes

Yes

#10

2

Yes

Yes

#6

1

Yes

Yes

#4

1

Yes

No

#10

2

Yes

#4

1

No

Description

Yes
Yes
BA

41

81

91

82

92

S

Cu Crimp

Cu single
Set Screw
Cu Double
Set Screw
Al single
Set Screw
Al double
Set Screw

Cu Stud

#6

2

Yes

Yes

(breakaway

#2

1

No

Yes

version equipped
with breakaway

#2–#12

1

Yes

Yes

stud,breakaway
boot, and

#2–#12

#2–#12

#2–#12

N/A

1
each

1

1
each

1

insulating boots
Yes

Yes

for both line and
load sides)

Yes

Yes

Yes

Yes

N/A

N/A

Notes:
1. Non-breakaway units do not include insulator boots. These optional cone shaped boots are available to provide a watertight installation. The insulator boots are
designed to form a watertight seal over conductors, but due to varying wire insulation sizes it is suggested that tape wrap be utilized for best results.
FSB1 = Single conductor boot (used to cover all crimp type & single set screw terminals)
FSB2 = Double conductor boot (used to cover all double set screw (Y-type) terminals)
Insulator boot trimming instructions: Locate wire gage size to be utilized marking on the boot and cut just beneath it.
2. Tightening torque for single and double set screw terminations: 35 lbs.-in.
3. Tightening torque for dual pole fastening screw: 10-15 lbs.-in.
4. FEBN versions have a permanently mounted dummy fuse for neutral applications.

H34

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

FEB,FEC,FEX,FEY 600 Volt In-Line Fuse Holders
Mersen In-Line Fuse Holder Family - Typical Combination Chart
	Midget
10x38mm

	Midget
10x38mm

Class CC

Breakaway

Class CC
Breakaway

	Midget
10x38mm
Dual Pole

	Midget
10x38mm

Class CC

Dual Pole

Dual Pole

Breakaway

Class CC
Dual Pole
Breakaway

FEB-11-11

FEB-11-11-BA

FEC-11-11

FEC-11-11-BA

FEX-11-11

FEX-11-11-BA

FEY-11-11

FEY-11-11-BA

FEB-11-21

FEB-11-21-BA

FEC-11-21

FEC-11-21-BA

FEX-11-21

FEX-11-21-BA

FEY-11-21

FEY-11-21-BA

FEX-11-41-BA

FEY-11-41

FEB-11-31

FEX-11-31

FEB-11-41

FEB-11-41-BA

FEB-11-82

FEB-11-82-BA

FEB-11-91

FEB-11-91-BA

FEB-11-92

FEB-11-92-BA

FEX-11-41

FEY-11-31

FEB-11-81-BA
FEC-11-91

FEC-11-91-BA

FEY-11-91-BA

FEC-21-21

FEC-21-21-BA

FEX-21-21

FEC-81-81

FEC-81-81-BA

FEX-81-81

FEB-11-S
FEB-21-11
FEB-21-21-BA
FEB-21-91-BA

FEB-31-31

FEB-31-31-BA

FEB-41-41

FEB-41-41-BA

FEB-81-81

FEB-81-81-BA

FEB-81-91

FEB-81-91-BA

FEX-81-91

FEX-21-21-BA

FEY-21-21

FEX-81-91-BA

FEY-81-91

FEY-21-21-BA

FEY-81-81-BA

FEB-81-S
FEB-82-82
FEB-82-92

H

FEB-21-21
FEB-21-91

FEB-82-82-BA
FEB-82-92-BA
FEB-91-91-BA

FEBN-11-11

FEBN-11-11-BA

FEBN-11-91

FEBN-11-91-BA

FEBN-81-81

FEBN-81-81-BA

FEX-81-91-BA

FEB-SS
FEX-81-91-BA

Note: Consult factory for other configurations.

Crimping Tools Reference Chart, the following
crimping tools (or equivalent) are recommended:
Terminal Type

FCI-Burndy

T&B

1

Y8MRB-1

WT-111M

2

Y2MR

TBM2/TBM5 BLUE DIE, WT-115-A DIE O

3

Y2MR

TBM2/TBM5 GREY DIE, WT-115-A DIE E

4

Y2MR

TBM2/TBM5 BROWN DIE, WT-115-A DIE F

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H35

FEB,FEC,FEX,FEY 600 Volt In-Line Fuse Holders
FEB and FEC, Non-Breakaway and Breakaway Assembly Drawings

4.3” (110mm)
8.0” (203mm) Assembled Length with Optional FSB1 Boots

4.7” (119mm)
5.8” (147mm) Assembled Length
9.0” (229mm) Assembled Length

FEX and FEY, Non-Breakaway and Breakaway Assembly Drawings

4.3” (109mm)
8.0” (203mm) Assembled Length with Optional FSB1 Boots

4.2” (106mm)
5.6” (142mm) Assembled Length
8.6” (218mm) Assembled Length

H36

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

GPM SERIES Panel Mount Fuse Holders
Mersen GPM panel mount fuse holders are in sizes to accommodate Class CC and
midget (1-1/2” x 13/32”) fuses. All 30A holders have glass-filled thermoplastic insulators
for extra dependability and trouble-free installation. Patented design allows same
body to accept screw or bayonet knob. Flange design allows front or rear mounting.

Catalog Numbers & Descriptions
Fig.

Cap Type

Amps

Volts

Fuse Type

Terminal Type

GPM-S

1

Screw Knob

30

600

1-1/2” x 13/32”

1/4” Quick-connect/
Solder

GPM-S90

2

Screw Knob

30

600

1-1/2” x 13/32”

1/4” Quick-connect/
Solder, Right Angle

GPM-SRR

1

Screw Knob

30

600

Class CC

1/4” Quick-connect/
Solder

GPM-SRR90

2

Screw Knob

30

600

Class CC

1/4” Quick-connect/
Solder, Right Angle

GPM-B

1

1/4 Turn Bayonet Knob

30

600

1-1/2” x 13/32”

1/4” Quick-connect/
Solder

GPM-B90

2

1/4 Turn Bayonet Knob

30

600

1-1/2” x 13/32”

1/4” Quick-connect/
Solder, Right Angle

Ratings:

Class CC

1/4” Quick-connect/
Solder

Volts	

GPM-BRR

1

1/4 Turn Bayonet Knob

30

600

GPM-BRR90

2

1/4 Turn Bayonet Knob

30

600

Class CC

1/4” Quick-connect/
Solder, Right Angle

GPM-WT

1

Water-tight Screw Knob

30

600

1-1/2” x 13/32”

1/4” Quick-connect/
Solder

GPM-WT90

2

Water-tight Screw Knob

30

600

1-1/2” x 13/32”

1/4” Quick-connect/
Solder, Right Angle

GPM-WTR

1

Water-tight Screw Knob

30

600

Class CC

1/4” Quick-connect/
Solder

GPM-WTR90

2

Water-tight Screw Knob

30

600

Class CC

1/4” Quick-connect/
Solder, Right Angle

: 600VAC / DC

Amps	 : 30A Maximum
SCCR	 : 200kA (Class CC Fuses)
	

: 100kA (Midget Fuses)

H

Catalog No.

Approvals:
•• UL Recognized, guide IZLT2,
File E52283
•• CSA Certified - C22.2, class
6225, File 32169

Figure 1

Figure 2

Recommended Fuse Usage:
GPM Fuse Holders will accommodate these Mersen fuses:	
GPM-SRR, GPM-BRR, GPM-WTR: ATQR, ATDR, ATMR,
GPM-SRR90, GPM-BRR90, GPM-WTR90: ATQR, ATDR, ATMR,
GPM-S, GPM-B, GPM-WT: ATQ, ATM, TRM, OTM, GGU, A13X-2, A25Z-2, A60Q-2, A6Y-2B,
GPM-S90, GPM-B90, GPM-WT90: ATQ, ATM, TRM, OTM, GGU, A13X-2, A25Z-2, A60Q-2,
A6Y-2B
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H37

GPM SERIES Panel Mount Fuse Holders
Mersen GPM panel mount fuse holders will accommodate 1” x 1-1/4” 3AG fuses and 5mm
x 20mm fuses; most are approved by U.L. and CSA. Cap and body material is bakelite
or polycarbonate and function as a screw-in or bayonet style closure. Finger-grip or
screwdriver slots are available. All holders are rated for up to 250 volts with amp ratings
ranging from 3A to 15A.
Catalog No.

Cap Type

Volts

Amps

Fuse Size

Terminal Type

Approvals

GPM-A

Finger-grip/Screw-in

250

10

5mm x 20mm

Solder

UR/CSA

GPM-A1

Finger-grip/Screw-in

250

10

5mm x 20mm

Solder

GPM-A2

Finger-grip/Screw-in

250

10

5mm x 20mm

Solder

UR/CSA

GPM-A3

Finger-grip/Screw-in

250

3

5mm x 20mm

Solder

UR/CSA

GPM-A4

Finger-grip/Screw-in

250

6.3

5mm x 20mm

Solder, right angle

GPM-A5

Screwdriver Slot

250

10

5mm x 20mm

Solder

GPM-A6

Screwdriver Slot

250

6.3

5mm x 20mm

Solder, right angle

UR/CSA

GPM-A8

Screwdriver Slot

250

10

5mm x 20mm

Solder, right angle

UR/CSA

GPM-A9

Screwdriver Slot

250

6.3

5mm x 20mm

Solder, right angle

UR/CSA

GPM-A10

Screwdriver Slot

250

6.3

5mm x 20mm

3/16”Solder/QC

UR/CSA

GPM-A11

Screwdriver Slot

250

10

5mm x 20mm

Solder, right angle

UR/CSA

Recommended Fuse Usage:
GPM-A: GGM, GGA, GSB, GSC, GDG, GSD, GSF
All dimensions mm’s

GPM-A

H38

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

GPM-A1

www.barr-thorp.com

GPM SERIES Panel Mount Fuse Holders

GPM-A3

GPM-A4

GPM-A5

H

GPM-A2

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H39

GPM SERIES Panel Mount Fuse Holders

H40

GPM-A6

GPM-A8

GPM-A9

GPM-A10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

GPM SERIES Panel Mount Fuse Holders

GPM-A11

Cap Type

Volts

Amps

Fuse Size

Terminal Type

Approvals

GPM-G

Finger-grip/Screw-in

250

15

3AG

3/16” Solder/QC

UR/CSA

GPM-G1

Finger-grip/Screw-in

250

10

3AG

3/16” Solder/QC

UR/CSA

GPM-G2

Finger-grip/Screw-in

250

10

3AG

Solder

GPM-G3

Screwdriver Slot

250

10

3AG

Solder

UR/CSA

GPM-G5

Finger-grip/Bayonet

250

10

3AG

1/4” Solder/QC

UR/CSA

GPM-G6

Finger-grip/Bayonet

250

10

3AG

Solder

UR/CSA

GPM-G7

Screwdriver Slot

250

15

3AG

3/16” Solder/QC

UR/CSA

GPM-G8

Finger-grip/Screw-in

250

15

3AG

Quick-connect

H

Catalog No.

Recommended Fuse Usage:
GPM-G:	GGC, GDL, GSA, GAB
All dimensions mm’s	

GPM-G

GPM-G1

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H41

GPM SERIES Panel Mount Fuse Holders

H42

GPM-G2

GPM-G3

GPM-G5

GPM-G6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

GPM SERIES Panel Mount Fuse Holders

H

GPM-G7

GPM-G8

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H43

P243/P266/P292 Fuse Blocks
Fuse Blocks for Semiconductor Fuses
Mersen P243 and P266 series fuse blocks for Form 101 fuses are glass-filled
polycarbonate or laminated phenolic insulator blocks with studs to accommodate boltin fuses. The P292 series has a laminated phenolic insulator base with fuse clips. All
studs, clips and mounting hardware are tin or zinc plated.

Dimensions
For Use
with
A13X, A15QS
A13X, A15QS
A25X, A25Z,
A30QS
A25X, A25Z,
A30QS
A25X, A25Z,
A30QS
A50P
A50P, A50QS
A50P, A50QS
A60X, A60Z,
A70QS-4
A60X, A60Z,
A70QS-4
A70P, A70Q,
A70QS-4
A70QS-4K
A70P, A70Q
A70P, A70Q,
A70QS-4K
A100P
A100P
A120X
A30QS
A50QS
A50QS
A70QS-4K

Dimensions - Inches

Catalog

Stud

Torque

Size

(in lbs)

A

B

C

D

E

F

2
2

4.40
4.40

1.50
1.50

2.79
2.79

2.20
2.20

2.06
2.44

1.17
0.98

1/4-20
5/16-18

36
84

P243G

2

4.40

1.50

2.79

2.20

2.44

0.98

5/16-18

84

70-200

P243

1

4.50

1.50

2.50

2.25

2.38

1.06

1/4-20

36

225-600

P243G

2

4.40

1.50

2.79

2.20

2.44

0.98

5/16-18

84

35-60
70-200
225-600

P243G
P243E
P266C

2
2
1

4.40
4.40
6.00

1.50
1.50
2.00

2.79
2.79
3.00

2.20
2.20
3.00

2.44
2.88
3.28

0.98
0.76
1.36

5/16-18
1/4-20
3/8-16

84
36
144

35-200

P243C

2

4.40

1.50

2.79

2.20

3.62

0.39

1/4-20

36

225-600

P266A

1

6.00

2.00

3.00

3.00

4.06

0.97

3/8-16

144

35-100

P243C

2

4.40

1.50

2.79

2.20

3.62

0.39

1/4-20

36

125-200
125-400

P266A
P266A

1
1

6.00
6.00

2.00
2.00

3.00
3.00

3.00
3.00

4.06
4.06

0.97
0.97

3/8-16
3/8-16

144
144

450-600

P266F

1

8.00

2.50

3.00

4.00

5.09

1.45

3/8-16

144

35-100
125-400
1-30
700-800
700-800
900-1000
450-600

P266G
P266L
P292
FH25F4
FH50F4
FH50F5
FH70F3

1
1
3
1
1
1
1

6.00
6.00
6.00
8.00
8.00
8.00

2.00
2.00
2.00
2.50
2.50
2.50

2.50
3.00
3.00
3.00
3.00
3.00

3.00
3.00
3.00
4.00
4.50
4.00

4.25
4.66
2.66
4.21
4.97
5.09

0.88
0.67
1.67
1.84
1.50
1.91

1/4-20
3/8-16
3/8-16
1/2-13
1/2-13
1/2-13

36
144
144
360
360
360

Amps

No.

Fig.

70-450
500-600

P243D
P243G

35-60

Note: FH Blocks are 1” thick.
* Not UL or CSA Certified

Ratings:
Amps	

: 1 to 1000A

Clip Type : 1200VAC or less	
Stud Type : 1000VAC or less

Approvals:
•• UL Recognized Component
guide IZLT2 File E52283
•• CSA Certified C22.2, class
6225, File 32169

Figure 1

Figure 2

H44

Figure 3

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

1SC/1MSC

Modular Semiconductor Fuse Blocks
Mersen 1SC and 1MSC semiconductor fuse blocks feature modular mounting that
offers greater flexibility in adjusting to various fuse lengths. Both stud type and
integral box connector versions are offered to allow for user preference of wire
terminations. The integeral box connector versions also provide for greater heat
dissipation. All modular blocks are sold in pairs but need to be ordered as two items
to suit one fuse. Mounting hardware is supplied with the blocks.

Figure 1

Figure 2

Figure 3

Ratings:
1SC
Volts	

: 1000V

SCCR	 : 200kA

H

Amps	 : 800A Maximum

1MSC
Volts	

: 600V

Amps	 : 600A Maximum

Figure 4

SCCR	 : 200kA

Figure 5

Approvals:
•• UL Recognized Component
File for 1SC: E52283
File for 1MSC: E35113

Figure 6

Dimensions
Catalog

Voltage

Ampere

No.

Rating

Rating

1SC250

1,000

400

1SC375

1,000

1MSC101

600

1MSC102

600

1MSC103

Connector

UR

Hardware

Tightning Tourque
(lb.-in.)

Fig.

Type

Wire Range

Bolt

Washer

Fuse

Cable

Yes

1/4” Stud

—

—

—

61

61

1

800

Yes

3/8” Stud

—

—

—

192

192

2

100

Yes

Al Box

Al/Cu 2/0 - #6

1/4”

0.655”

120

120

3

400

Yes

Al Box

Al/Cu (2) 250kcmil - #6

1/4”

0.655”

275

275

4

600

400

Yes

Al Box

Al/Cu (2) 250kcmil - #6

3/8”

0.900”

275

275

5

1MSC104

600

600

Yes

Al Box

Al/Cu (2) 250kcmil - #6

3/8”

0.900”

375

375

6

1SCM8

1,000

400

Yes

M8 Stud

—

—

—

60

60

1

1SCM10

1,000

800

Yes

M10 Stud

—

—

—

190

190

2

*Consult Factory
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H45

703,U705,U710

Semiconductor Fuse Holders
750V Semiconductor Fuse Holders
Mersen semiconductor fuse holders feature open face styles. Each version is rated
750 volts and accommodates 14 x 51 mm or 22 x 58 mm fuses. 703, U705 and U710
holders feature Mersen’s unique adder-block design which can be snapped onto 1-,
2-, or 3-pole blocks to form multi-pole segmented blocks of as many poles as desired.
A choice of box, screw or pressure plate connectors is offered to fit a wide range of
standard or solid copper wire. All versions have verified dielectric strengths in excess
of 2500V. A patented built-in DIN-rail adapter on the U710 blocks adds further design
versatiltiy. All fuse clips are made of high conductivity tin-plated copper with spring
reinforced clips.

Highlights:

Applications:

•• Thermoplastic bases

•• All circuits up to 750 volts

•• DIN-rail (U710) or Screw Mount

using semiconductor fuses for

Ratings:

•• Adder block design

protection of small inverters, UPS

Volts	

systems, motor drives, etc.

Amps	 : 30A (703)

: 750V

	

: 50A (U7050)

	

: 100A (U7100)

Recommended Fuse Usage:

SCCR	 : 200kA dependent on 	

703 use with 14x51mm A70QS, A70P, URD

	

fuse I.R.

U705 use with 14x51mm A70QS, A70P, URD
U710 use with 22x58mm A70QS, URD, up to 100A

Approvals:
•• UL Recognized component
guide IZLT2, File E52283
•• CSA Certified class 6225,
File 32169

H46

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

703,U705,U710 Semiconductor Fuse Holders
750 Volt Fuse Holders for 14 x 51mm & 22 x 58 mm Fuses
Fuse

Ampacity

No.

Size

Rating

U70505
U70506
U70507

Poles

Connector
Type

Wire Range

50

1

Box

2

Al/Cu

2

#2-14

3

U70508

3

4

70315

Adder

1

70316
70317

14 x 51

30

70318

1

Screw

2
Adder
1

14 x 51

30

70328

3

Adder
1

70358

Cu

2

#10-14

3

Box

2

2

#4-14

3

U71005

Adder
1

U71008

2

35

4

U71006

100

20

1
Cu*

3

22 x 58

20

4

70355
30

35

1
Pressure Plate

2

70356

U71007

2

#10-14

3

14 x 51

(In-Lb)

4

70325

70357

Cu

3

70326
70327

Connector Torque

1

Adder
14 x 51

Figure

5
Box

A1/Cu

6

#2-14

7

3

H

Catalog

35

8

*Copper box connectors and clips-for copper wires only.
Note: To convert 30A adder pole to single pole, use end barrier #U09322 100A adder pole to single pole, use end barrier #U09372.

Recommended mounting screws; #10 (.190”dia)

Dimensions

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

Figure 7

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Figure 8

H47

PS 20x127 Ferrule Fuse Holders
and No-Load Disconnectors

Highlights:
•• Solid assembly offers good thermal and mechanical withstand rating
•• Fuse mounting in holders or no-load disconnectors with or without open fuse
indicating microswitches
•• Phenolic resin models for basic applications, fiber-glass polyester for applications
in corrosive atmospheres or applications for traction
•• Voltage = 1,500 V and 2,500 V

Dielectric withstand tests
R.M.S. voltage 1

Impulse voltage 1.2/50 s

mn 50/60 Hz

(IEC 694 et CEI 60)

Between close phases and phase and ground

6kV(1) - 10 kV(2)

Between phases and microswitch

12 kV

12 kV(1) - 20 kV(2)

Ratings:
Connecting with 16mm2 max. width, 5mm max. thick terminal

Volts	

: 1,500V

(1) Basic model

	

: 2,500V

Max. temperature (°C)/ Relative humidity (%): 20 °C/95% - 40°C/80% - 50°C/50%

SCCR	 : 42kA AC

(2) Salt spray-proof model

	

: 55kA DC

Moist tropical and equatorial climate or corrosive atmosphere.

Approvals:
•• UL Recognized component
File E113357

Dimensions
Insulation
Description

voltage rating Ui
AC 50/60 Hz or DC

PSI 20X127

1500 V without terminal
covers

Maximum operating current of fuse (A)
Fuse current
rating IN(A)

1000 V

=1000 V

=1000 V

=1500 V

=1500 V

gLB

gRC

gRB

gRB

gRD

50

2500 V with

63

80

terminal covers

80

90

PSIII 20X127 PRE

and only salt

100

100

PSIV 20X127 PRE

spray-proof model

125

PSI 20X127 PRE
PSII 20X127 PRE

Advised
copper wire
size mm2

50

10

56

16

No Operating Limit

25
35
50

Connecting with 50 mm2 max. cable with copper terminals or with a 15 x 8 max. rigid or flexible bar.

H48

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fire and fumes
class NF F 16101 and 102
and UL

basic model
12-F1 UL 94 V1
salt spray-proof
model I1 - F1
UL 94 VO

PS 20x127

Ferrule Fuse Holders and No-Load Disconnectors

Fuse Holders and Accessories

Description

Catalog No.

Weight (g)

Packaging

PSI 20x127

X 097310

260

3 pieces

PSI 20x127 + MCS BS

X 220130

290

2 pieces

PMCP 20+22
Catalog #: K 100036
Weight: 40g
Packaging: 1

Fuse non-load Disconnectors and Accessories

H

Twin terminal covers
PS 20
Catalog #: F 097226
Weight: 20g
Packaging: 3 twins

V: Connecting distance between centers
W: Clip for rail mounting in two positions
W’: With terminal cover length
Y: Space factor with a 90° fuse carrier position
Description (basic model)

Catalog No.

Z: Without terminal cover, space factor with a 180° fuse
carrier position
Z’: With terminal cover, space factor with 180° fuse carrier
position
No. of Poles

A

B

Preisolating and blown fuse
indicating microswitch features

PSI 20x127 PRE

F 097203

1

35

50

PSII 20x127 PRE

G 097227

2

69

84

PSIII 20x127 PRE

H 097228

3

103

118

PSIV 20x127 PRE

J 097229

4

137

152

PSI 20 x 127 PRE+MC PS

H 097205

PSII 20 x 127 PRE+MC PS

D 097293

PSIII 20 x 127 PRE+MC PS

E 097294

PSIV 20 x 127 PRE+MC PS

F 097295

Microswitch

Non-inductive circuit

rated current

interrupting rating

3A - 50 Hz

3A - 50 Hz

3A - DC

3A - DC

Reliable minimum operating voltage/current:
10V - 10mA
Connecting with 6.35 mm lug

Description
(salt spray-proof model)

Ref. No.

PSI 20x127 PRE BS

G 097204

PSII 20x127 PRE BS

L 097231

PSIII 20x127 PRE BS

T 097261

PSIV 20x127 PRE BS

C 097292

PSI 20 x 127 PRE BS+MC PS

J 097206

PSII 20 x 127 PRE BS+MC PS

G 097296

PSIII 20 x 127 PRE BS+MC PS

H 097297

PSIV 20 x 127 PRE BS+MC PS

J 097298

Distances when mounting on a conductive
board @ Ui = 2500 VAC

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H49

NH DIMENSION Fuse Bases
690V Ceramic fuse bases for NH fuse-links
•• Ceramic insulating bases
•• Silver plated contacts
•• High spring contact pressure
•• Screw mounting

Single-Pole Fuse Bases
Size

Rated Current (A)

Catalog No.

00-E

160

40002-G

00-EB

160

40003-G

0-E

160

40004-G

0-P

160

40006-G

1-P

250

40008-G

2-P

400

40010-G

3-P

630

40012-G

4-P

1250

40014-G

40002-G

40006-G

Rated Current (A)

Catalog No.

00-E

160

40502-G

00-EB

160

40503-G

0-E

160

40504-G

1-P

250

40508-G

2-P

400

40510-G

3-P

630

40512-G

Volts	

: 690V AC

Amps	 : 160-1250A

Three-Pole Fuse Bases
Size

Ratings:

Notes:		Size 1 fuse base will accept size 0 fuses.
	
Size 2 fuse base will accept size 1 fuses.
	
Size 3 fuse base will accept size 1 & 2 fuses.
	
Size 4 has a special nut to assure contact pressure.
	
Types E and EP have square contacts
	
Types P and PP have pincer contacts
	
Type EB has pressure-plate cable connection.

40510-G

Approvals:
Designed to meet standards:
•• IEC 60269-2-1
•• DIN, VDE 0636-21 & 201

Insulating Barriers for Ceramic NH Fuse Bases
Rated

Catalog

Current (A)

No.

00

100

45102-G

0

160

45104-G

1-2

400

45110-G

3

630

45112-G

Size

H50

00

100

45202-G

0

160

45204-G

1-2

400

45210-G

3

630

45212-G

4

1250

45214-G

•• DIN 43621

Friction Fit

Tab Fastened

45110-G

45212-G

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

NH DIMENSION Fuse Bases
00-E, EB

0-E

0-P

1-P

2-P

3-P

4-P

A

33

32

32

55

55

55

80

B

20

20

25

32

35

40

45

C

118.5

269

166

210

227

241

312

D

100

151

150

175

200

210

262

E*

8

8.5

8.5

11

11

11

11

F

-

-

-

30

30

30

45

G

14.5

14

14

22

22

22

-

H

25

25

25

25

25

25

30

I

145

185

185

250

250

250

-

J

21.5

29

29

35

35

35

45

K

8

8

8

10

10

12

16

L

55

72

74

84

84

84

111

M

52.5

60

60

71

89

103

145

N

80

85

85

100

100

127

-

O

84

120

120

148

148

148

192

P

34

47

47

62

69

82

-

Q

1

2

2

2

2

2

-

R

101

126

126

177

190

213

-

H

Dimensions of Ceramic Fuse Bases for NH Fuse-Links

* 8mm for all multiple pole bases; dimensions in chart for single pole bases.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H51

NH DIMENSION Fuse Bases
690V POLYESTER fuse bases for NH fuse-links
•• Polyester insulating bases
•• Silver plated contacts
•• High pressure spring contacts
•• Screw or rail mount

Type 00-EP* – Fuse Bases for NH-00 Fuse-Links
Catalog No.
Screw Connector

Pressure Plate Connector

Poles

Screw Mt.

Rail Mt.

Screw Mt.

Rail Mt.

1

41002-G

42002-G

41102-G

42102-G

2

41012-G

42012-G

41112-G

42112-G

3

41016-G

42016-G

41114-G

42114-G

4

41019-G

42019-G

41119-G

42119-G

* EP bases have square contacts.

Ratings:
Volts	

: 690VAC

Amps	 : 160 to 1250A

Connection Detail

41002-G

41014-G

Screw

Clamp

Dimensions

H52

00-EP

Approvals:

A

32

B

20

Designed to meet standards:

C

117

D

100

E

8

F

2

G

14

H

25

I

145

J

21.5

K

8

L

56

M

52

N

85

0

84

P

34

Q

1

R

104

•• IEC 60269-2-1
•• DIN, VDE 0636-21 & 201
•• DIN 43620

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

NH DIMENSION Fuse Bases
Type 0-EP* – Fuse Bases for NH-0 Fuse-Links
Catalog No.
Mounting Style
Screw

DIN-Rail

1

41202-G

42202-G

2

41212-G

42212-G

3

41214-G

42214-G

4

41219-G

42219-G

* EP bases have square contacts. PP bases
have pincer contacts.

42202-G

Type 0-PP – Fuse Bases
for NH-0 Fuse-Links

41412-G

41514-G

Type 2-PP – Fuse Bases
for NH-2 Fuse-Links

1

41302-G

42302-G

1

41502-G

42502-G

2

41312-G

42312-G

2

41512-G

42512-G

3

41314-G

42314-G

3

41514-G

42514-G

4

41319-G

42319-G

4

41519-G

42519-G

Type 1-PP – Fuse Bases for
NH-1 Fuse-Links

Type 3-PP – Fuse Bases for
NH-3 Fuse-Links

1

41402-G

42402-G

1

41602-G

42602-G

2

41412-G

42412-G

2

41612-G

42612-G

3

41414-G

42414-G

3

41614-G

42614-G

4

41419-G

42419-G

4

41619-G

42619-G

H

Poles

Dimensions of Polyester Fuse Bases for NH Fuse-Links
0-EP

O-PP

1-PP

2-PP

3-PP

A

46

46

60

60

60

B

20

25

32

35

40

C

168

168

209

225

241

D

150.5

150.5

176

201

210

E

7.5

7.5

10.5

10.5

10.5

F

-

-

30

30

30

G

14.5

14.5

20.5

20.5

20.5

H

25

25

25

25

25

I

185

185

250

250

270

J

29

29

35

35

35

K

M8

M8

M10

M10

M12

L

74

75

81

81

81

M

59

61

71

89

103

N

95

95

122.5

122.5

142.5

O

122

122

146

146

146

P

48.5

48.5

65.5

65.5

81.5

Q

94

94

125.5

125.5

141.5

R

142

142

191

191

223

S

190

190

256.5

256.5

304.5

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H53

NH DIMENSION Fuse Bases
Insulating Barriers for Polyester NH Fuse Bases
Rated

Catalog

Standard

Current (A)

No.

Pack

00

100

44502-G

2

0

160

44504-G

2

1-2

400

44510-G

2

3

630

44512-G

2

Size

*Not for use with
41016-G and 42016-G.
Use 84392-G.
44502-G

44510-G

Separators
0

160

44604-G

2

1-2

400

44610-G

2

3

630

44612-G

2

3

630

44512-G

2

44610-G

44702-G

Fuse Shields

Terminal Shields

00

100

44802-G

3

0

160

44804-G

3

1-2

400

44810-G

3

00

100

44702-G

6

3

630

44512-G

2

0

160

44704-G

6

1-2

400

44710-G

6

44802-G

One Cable – Terminal for NH Bases
Base

Cable Size (mm)

Catalog

Standard

Size

Max.

Min.

Number

Pack

00

50

6

45421-G

60

00-0

95

10

45423-G

50

1

150

16

45425-G

30

2-3

240

50

45427-G

15

45425-G

Two Cable – Terminal for NH Bases
Base

Cable 1 (Size mm)

Cable 2 (Size mm)

Catalog

Standard

Size

Max.

Min.

Max.

Min.

Number

Pack

00

50

6

50

6

45431-G

60

00-0

95

10

95

10

45433-G

30

1

150

25

150

16

45435-G

20

2-3

240

95

240

50

45437-G

5

45435-G

Dimensions of Terminals

H54

Catalog No.

A

B

C

M

45421-G

18

26

34

6

45423-G

24

35

52

8

45425-G

26

41

58

10

45427-G

36

53

68

12

45431-G

18

26

39

6

45433-G

24

35

82

8

45435-G

26

41

84

10

45437-G

36

53

98

12

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

DFC SERIES Dead-Front Fuse Covers
Mersen DFC dead-front fuse covers snap on to individual fuses installed in fuse
blocks, covering exposed live clips and terminals and reducing accidental contact
by personnel. They are sized to fit Class G, H, J, K, R, CC or midget fuses for
increased safety and (optional) open-fuse indication. All DFC dead-front fuse covers
are reusable when a fuse is replaced – simply detach from the open fuse and reattach to the new replacement fuse. On indicator models an orange indicator light
will illuminate to indicate an open fuse. DFC fuse cover ends can be easily cut to
accommodate existing wiring, safety switches or special installations. A blank label is
provided with each DFC to write in circuit or fuse information.

Features/Benefits:
•• Innovative design provides dead-front electrical safety to personnel
•• Optional orange indicator light shows open fuse
•• Many sizes to fit virtually all popular fuses/fuse blocks
•• Reusable with no changes or additional cost

Ratings:

•• Labels provided for write-in identification

Non-Indicating

•• Thermoplastic flammability rating of UL 94-V2

Volts	

•• Low leakage current <0.6 mA at 600V

	

Nonindicating

Indicating	

Fuses Accomodated

indicating

200A

Dimensions (inches)

Volts	

: 90 to 600VAC

	

: 115 to 600VDC

Amps

Volts

Class

A

B

C

DFC-1

DFC-1I

0-30

600

J

4.68

1.36

1.97

DFC-2

DFC-2I

0-30

600

R, K, H

7.45

1.35

1.80

DFC-3

DFC-3I

65-100

600

J

7.57

1.30

2.20

DFC-4

DFC-4I

65-100

250

R, K, H

8.73

1.40

2.02

DFC-5

DFC-5I

35-60

600

R, K, H

7.46

1.35

2.00

DFC-6

DFC-6I

35-60

600

J

4.64

1.40

2.17

DFC-7

DFC-7I

0-30

600

Midget, CC, G

3.71

0.69

1.37

DFC-8

DFC-8I

65-100

600

R, K, H

10.55

1.55

2.26

DFC-9

DFC-9I

0-30

250

R, K, H

3.71

0.85

1.55

DFC-10

DFC-10I

0-30

600

SJ

4.56

1.06

2.02

DFC-11

DFC-11I

65-100

600

SJ

5.52

1.7

2.04

DFC-12

DFC-12I

200

600

J

6.63

3.03

2.86

WARNING: To avoid electrical shock, TURN POWER OFF before installing, removing or servicing.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

H

Amps	 : Fits fuses rated 0 to 	

Catalog Numbers & Dimensions
Catalog Numbers

: 0 to 600VAC / DC

Amps	 : Fits fuses rated 0 to 	
	

200A

Approvals:
•• UL Listed (All except midget
size) guide JDVS, File E90426
•• UL Recognized Component
(midget) guide JDVS2, File
E90426
•• CSA Certified class 6228, File
70159

www.barr-thorp.com

H55

DFC SERIES Dead-Front Fuse Covers
Fuses and Fuse Blocks for use with DFC
Fuse

Fuse Block

DFC

Fuse

Fuse Block

DFC

AG(0-30)

40xxxG

-7I, -7

A6K(35-60)R

606xxR

-5I, -5

AJT(1-30)

603xxJ

-1I, -1

A6K(70-100)R

610xxR

-8I, -8

AJT(1-30)

603xxSJ

10I, -10

A6Y(0-30)-2B

303xx

-7I, -7

AJT(35-60)

606xxJ

-6I, -6

A60Q(0-30)-2

303xx

-7I, -7

AJT(70-100)

610xxJ

-3I, -3

A60X(0-30)-1

603xx

-1I, -1

AJT(70-100)

6100xxSJ

-11I, -11

A70P(10-30)-1

203xx

-9I, -9

AJT(110-200)

620xxJ

-12I, -12

GFN(0-30)

303xx

-7I, -7

ATDR(0-30)

303xxR

-7I, -7

GGU(0-30)

303xx

-7I, -7

ATM(0-30)

303xx

-7I, -7

HSJ(15-30)

603xxSJ

-10I, -10

ATMR(0-30)

303xxR

-7I, -7

HSJ(70-100)

6100xxSJ

-11I, -11

ATQ(0-30)

303xx

-7I, -7

HSJ(110-200)

620xxJ

-12I, -12

ATQR(0-30)

303xxR

-7I, -7

OT(0-30)

203xx

-9I, -9

A13X(1-30)-2

303xx

-7I, -7

OT(35-60)

206xx

A2D(0-30)R

203xxR

-9I, -9

OT(65-100)

210xx

-4I, -4

A2D(35-60)R

206xxR

OTM(0-30)

303xx

-7I, -7

A2D(65-100)R

210xxR

-4I, -4

OTS(0-30)

603xx

-2I, -2

A2K(0-30)R

203xxR

-9I, -9

OTS(35-60)

606xx

-5I, -5

A2K(35-60)R

206xxR

OTS(65-100)

610xx

-8I, -8

A2K(70-100)R

210xxR

-4I, -4

RF(0-30)

203xx

-9I, -9

A2Y(0-30)

203xx

-9I, -9

RF(35-60)

206xx

A2Y(35-60)

206xx

RF(65-100)

210xx

-4I, -4

A2Y(70-100)

210xx

-4I, -4

RFS(0-30)

603xx

-2I, -2

A25X(1-30)-1

203xx

-9I, -9

RFS(35-60)

606xx

-5I, -5

A25Z(1-30)-2

303xx

-7I, -7

RFS(65-100)

610xx

-8I, -8

A4J(1-30)

603xxJ

-1I, -1

TR(0-30)R

203xx

-9I, -9

A4J(1-30)

603xxSJ

-10I, -10

TR(35-60)R

206xx

A4J(35-60)

606xxJ

-6I, -6

TR(70-100)R

210xx

-4I, -4

A4J(70-100)

610xxJ

-3I, -3

TRM(0-30)

303xx

-7I, -7

A4J(70-100)

6100xxSJ

-11I, -11

TRS(0-30)R

603xxR

-2I, -2

A4J(110-200)

620xxJ

-12I, -12

TRS(35-60)R

606xxR

-5I, -5

A50P(10-30)

203xx

-9I, -9

TRS(65-100)R

610xxR

-8I, -8

A6D(0-30)R

603xxR

-2I, -2

TRS(35-60)RDC

606xxR

-5I, -5

A6D(35-60)R

606xxR

-5I, -5

TRS(70-100)RDC

610xxR

-8I, -8

A6D(70-100)R

610xxR

-8I, -8

A6K(0-30)R

603xxR

-2I, -2

Note: DFC Covers fit single pole blocks and each pole of multi-pole blocks. Consult factory for data
sheets of DFC trim instructions for safety switches.
WARNING: To avoid electrical shock, TURN POWER OFF before installing, removing or servicing.

H56

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Power Distribution Blocks
A powerful way to manage your power distribution challenges.

Your problem:
You’re facing
the enormously
complex wiring
requirements of

I

Power Distribution Blocks

• Finger-Safe / FSPDB Series...............I2

an automated

• Open Style 62000-69000....................I4

manufacturing

• 62000-63000 Mini Series....................I5

facility. Or the
compatibility
problems of a

• 66000-67000 Intermediate Series.......I6
• 68000-69000 Large Series..................I8

commercial complex retrofit. Or the need for seamless electrical
service in a hospital annex that’s anything but seamless. Where
can you turn to solve your power distribution problems?
Our solution: Well beyond circuit protection solutions. Mersen
offers you an arsenal of circuit management products. One of

I

which is our line of polycarbonate 600V / 90 to 1520A Power
Distribution Blocks. Safe and convenient, durable and easy to
install, they’re the simple way to split primary power circuits into
secondary circuits — or provide fixed-junction tap-off points.
Either way, our full range of sizes accommodate any gauge
aluminum or copper conductor. Exclusive adder poles snap onto
the 1, 2, or 3-pole blocks for maximum pole flexibility . . . and
safety covers are available.
Want more information fast? For more technical or applicationspecific information, please call our Power Distribution Block
experts, at 978-462-6662; 416-252-9371 in Canada; or visit our
website at us-ferrazshawmut.mersen.com.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

DFC3M/DFC3LP/DRM
Fuse Block Accessories

DFC3M safety puller protects personnel, covers live parts
The DFC3M safety puller is intended to hold and safely enclose 1-1/2” x 13/32”
midget or Class CC fuses for insertion or removal from fuse clips, making fuse
installation easy and safe without the use of a standard fuse puller. The DFC3M is
made of clear polycarbonate, so the fuse can be identified when installed in a 303
series fuse block.

DFC3LP safety puller holds fuse, protects personnel, and
saves space
The DFC3LP holds and safely encloses 1-1/2” x 13/32” midget or class CC fuse,
similar to the DFC3M, but with a lower profile in height so it takes less room where
space is restricted. The DFC3LP is made of clear polycarbonate so the fuse can be
seen after installation in a fuse block such as the Mersen 303 series.

DRM adapts 303 series midget and class CC fuse blocks to
DIN-rail
The DIN-rail adapter, DRM, provides quick mounting for all Mersen 303 series midget

H

and class CC fuse blocks to all symmetrical 35mm DIN or asymmetrical 32mm “G”
rail. A DRM adapter is attached to each pole with the screw provided. The DRM is
molded of black polycarbonate and is mounted or dismounted from the rail simply by
depressing the finger pull.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

H57

FUSE CLIPS

For Ferrule Fuses/PC Board Mount
30A & 60A Ferrule - Fuse Clips
Fuse Clips for 30 & 60 Ampere Ferrule-type Fuses
For Fuse Rating/Size

Mounting Details

Cat. No.

Volts

Amps (max)

Ferrule Dia.

Hole Size

Screw Size

C08915P

600

30

13/32”

.72 dia.

#8

C08919P

600

30

13/32”

.196 dia.

#10

C08916P

250

30

9/16”

.172 dia.

#8

C08917P

250

60

13/16”

.22 X .30”

#10

600

30

13/16”

.22 X .30”

#10

600

60

1-1/16”

.22 X .30”

#10

C08918P

All clips are UL recognized: guide IZLT2, file E52283
All clips are tin-plated copper alloy, non-spring reinforced.

CO8915P
CO8919P

CO8917P

CO8916P

SDC5 PC BOARD clips
•• PC board mount fuse clip

CO8918P

.34”
(8.6mm)

.14”
(3.56mm)

•• For 5mm diameter fuses

.20”
(5mm)

•• Tin plated hard brass

.066”
(1.67mm)
.280”
(7.1mm)

SDC6 PC BOARD clips
•• PC board mount fuse clip
•• For 1/4” diameter fuses

.425”
(0.8mm)

•• Tin plated hard brass
.30”
(7.6mm)

.312”

(7.9mm)

.43
(11mm)

SDC7 PC BOARD clips
•• PC board mount fuse clip	
•• For 13/32” diameter fuses	
•• Tin plated hard brass

.73
(18.5mm)

.17 (4.4mm)
.42

(10.7mm)

H58

.48
(12.3mm)

.08
(2mm)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

FSPDB Finger-Safe Power Distribution Blocks
Safety evolving
Mersen FSPDBs introduce a new level of safety and ease for installing power
distribution blocks. An IP20 level of finger-safe protection is achieved using FSPDBs,
eliminating the need for special covers or custom Plexiglas sheets to protect your
panels. FSPDBs (sizes 1 to 4) simply snap onto 35mm DIN rail to provide the quickest
installation. Modular design also allows for multi pole applications by use of assembly
pins. FSPDBs provide a safe, convenient way of splicing cables, splitting primary power
into a variety of secondary circuits or providing a fixed junction tap-off point.

Features/Benefits:
•• Finger-safe protection
Fully insulated block ensures touch safe isolation of live parts. Recessed
termination screws and wire openings provide IP20 grade protection and
qualify as “finger-safe” per IEC 529.
•• Compact modularity
Single or multiple pole configurations in the most compact footprint. Allows
users to build smaller or higher density panels.
•• Snap on DIN-rail mounting
Sizes 1 to 4 feature integral DIN rail adaptors allowing for quick and easy
installations on 35mm DIN rail yielding lower installed costs.
•• Captive termination screws
Unique channel design ensures captive metric wire termination screws.
Screws can never be lost.

Ratings:
Volts	

: 600V

Amps: 	 : 175 to 840A
SCCR	 : 100kA with proper fuse.
Contact Technical Services for
instruction sheet and/or DC
Ratings.	

•• Available accessories
For multi-pole panel mounting, simply snap in pins for rigid fit. Cap plugs
provide the ability to maintain touch safety on unused openings. Circuit
identification markers simply snap into blocks to ID circuits. End anchors
provide rigid end stops.
•• Multiple wire ratings
Provide users more versatility by offering capability of using multiple
conductors in #2 and 2/0 openings.

Approvals:
•• UL Recognized Component
Guide XCFR2, File E73571
•• CSA Certified: Class 6228, File

•• AC & DC ratings
FSPDB1, 2, and 3 have been evaluated for use at 1000V (AC or DC)

69363

provided they are installed on DIN-rails only and with barriers between
poles of opposite polarity of sufficient size to maintain required spacings.

I2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

FSPDB Finger-Safe Power Distribution Blocks
Catalog Numbers
Catalog Number

Ampere

Line

Rating

Aluminum

Copper

(Connector

(Connector

rated for 90° C

rated for 75° C

Cu/AL wire)

Cu wire only)

FSPDB1A

FSPDB1C

FSPDB2A

FSPDB2C

FSPDB3A

FSPDB3C

310

FSPDB4A

FSPDB4C

FSPDB5A

FSPDB5C

Load

Wire Range

(Based on NEC
Table 310-16 for

AWG/

Circuit

Openings

Current

mm2

Per Pole

2/0-#14

70-2.5

1

100kA•

#2-#14

35-2.5

4

100kA•

1

#8-#14

8-2.5

8

100kA•

AWG/

mm2

Openings

175

2/0-#14

70-2.5

1

175

2/0-#14

70-2.5

1

75° C Cu wire

Short

Wire Range
kcmil

only)

Rating

350-#6

185-16

2/0-#14

70-2.5

335

400-#6

185-16

1

400-#6

185-16

1

100kA•

840

600-#4

300-25

2

600-#4

300-25

2

100kA•

Contact Mersen Technical Services at technicalservices.nby@mersen.com for fuse type and maximum ampere required.

•

Multiple Wire Ratings (Same Size & Type Wires Only)
2/0 Openings

#2 Openings

(2) #4 AWG

(2) #10 AWG

(2) #6 AWG

(2-4) #12 AWG

(2) #6 AWG

(2) #12 AWG

(2) #8 AWG

(2-4) #14 AWG

(2) #8 AWG

(2) #14 AWG

(2-4) #10 AWG

Accessories

Dimension

FSPDB1A

FSPDB2A

FSPDB3A

FSPDB4A

FSPDB5A

FSPDB1C

FSPDB2C

FSPDB3C

FSPDB4C

FSPDB5C

Figure 1

Figure 1

Figure 2

Figure 1

Figure 2

mm

in

mm

in

mm

in

mm

in

mm

in

A

25.4

1.00

28.4

1.12

46.9

1.85

39

1.54

72

2.84

B

43.3

1.70

57.8

2.28

64.3

2.53

108

4.25

91

3.58

C

49.5

1.95

56.0

2.21

64.3

2.53

80

3.15

80

3.15

D

45.1

1.78

51.6

2.03

59.8

2.36

75.5

2.97

-

-

E

39.4

1.55

39.4

1.55

51.5

2.03

50.1

1.97

50.1

1.97

F

72.6

2.86

87.7

3.45

100.8

3.97

145.5

5.73

145

5.71

G

59.6

2.35

74.6

2.94

82.4

3.24

120.6

4.75

127.5

5.02

H

5.3

0.21

5.1

0.20

6.5

0.26

7

0.28

3

0.12

I

-

-

-

-

31.5

1.24

-

-

52

2.04

J

5.3

0.21

6.4

0.25

6.5

0.26

6.5

0.26

6.5

0.26

K

10

0.40

11.7

0.46

8.9

0.35

16

0.63

8.5

0.34

Catalog No.

Description
Accessory pin to form multiple pole

FSPIN1

block

I

Dimensions

Circuit identification marker for 2/0 &

FSCIM1

#2 max. conductors (Qty of 100)
Circuit identification marker for 350,

FSCIM2

400 & 600 kcmil max. conductors (Qty
of 100)

FSCAP1

Cap plug for spare 2/0 openings

FSCAP2

Cap plug for spare 350 kcmil openings

FSCP3

Cap plug for spare 600 kcmil opening

FSEA

Pair of end anchors

H
K

Figure 1

H

Figure 2

K

G
B

G
B

F

F

J

E
D

A
C

I

E

J
D

A

C

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

I3

Open Style PDBs 62000-69000
Versatile Power Distribution Blocks for cable terminations
Mersen Power Distribution Blocks afford a safe, convenient way of splicing cables,
splitting primary power into a variety of secondary circuits or providing a fixed
junction tap-off point. Power block options include single or dual primary connections
with up to 30 secondary connections.

Features/Benefits:
•• Adder Poles
All series have optional adder poles which snap onto the 1, 2 or 3- pole
blocks and lock together to form as many poles as required. Adder poles
with a variety of terminations can be combined to match special wire size
combinations.
•• Wire Connectors					
Standard aluminum box connectors accommodate aluminum or copper
wire, 1 conductor per opening. Standard copper box connections are for
copper wire only, 1 conductor per opening. Connectors are all 1 piece and
tin plated.
•• Insulators				
Insulators are virtually unbreakable, glass-filled polycarbonate on all
series. “See-through” safety covers are available, which give greater
safety and provide service entrance ratings for large and intermediate
series blocks.

Ratings:
Volts	

: 600V

Amps	 : 90 to 2660A
SCCR	 : 100kA with proper fuse.
Contact technical services for
sizing table.	

Highlights:

Applications:

•• Mini - 62000 and 63000 Series

•• Box, stud and quick-connect

•• Intermediate - 66000 and 67000
Series

terminations for copper and/or
aluminum cables

•• Large - 68000 and 69000 Series

Approvals:
•• Most sizes are UL Recognized
Component -Guide XCFR2, File
E73571
•• Most sizes are CSA Certified:
•• Series 62, 63, 66, 68 - Class
6228, File 69363	
•• Series 67, 69 - Class 3211,
File 15469

I4

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Mini 62000-63000 Series
Catalog Numbers
Ampere rating based on NEC Table 310-16 for 75ºC copper wire.
Primary

Secondary

Wire Range

Openings

Wire Range

Openings

AWG/kcmiL

or Studs

AWG/kcmiL

or Studs

or Stud Size

per Pole

or Stud Size

per Pole

1

#4-14

Aluminum

Ampere
Rating
(A)

Copper

Short
Circuit

Adder

1-Pole

2-Pole

3-Pole

Adder

1-Pole

2-Pole

3-Pole

Current
Rating

Box to Box
#4-14

2/0-#14

1

1
4

2/0-#14

1

#2-14

2

#4-14

4

1/4-20 x 5/8

1

1/4-20 x 1/2

1

90

85

185

175

185

175

63100

63101

63102

63103

62100

62101

62102

62103

100kA•

63160

63161

63162

63163

62160

62161

62162

62163

100kA•

63150

63151

63152

63153

62150

62151

62152

62153

100kA•

63190

63191

63192

63193

62190

62191

62192

62193

100kA•

63130

63131

63132

63133

62130

62131

62132

62133

100kA•

63140

63141

63142

63143

62140

62141

62142

62143

100kA•

62170

62171

62172

62173

100kA•

Box to Stud
2/0-#14

1

Tapped hole
Stud to Stud
1/4-20 x 5/8

1

1/4-20 x 5/8

1

240

240

-

-

-

-

62200

62201

62202

62203

100kA•

1/4 x .032QC

4

90

95

-

-

-

-

62210†

62211†

62212†

62213†

-

Box to Quick Connect
#4-14

1

I

*Studs are furnished with nuts and washers. Recommended stud torque: (1/4-20) - 72 in. lbs.			
†Quick connector, not CSA Certified.
Note: Blocks for 5, 6 and 10 poles are also available. To order, simply modify the Adder catalog number. Example: 63100 becomes 63106 for 6 poles.
•
Short circuit current rating with correctly sized fuse 100kA except adder block. Contact Mersen technical services for fuse type and maximum ampere required.
#Connectors are rated for 90º C wire.
	

Dimensions
Number

Dimension

of Poles

A (In.)

Adder

.812

1

1.09

2

1.90

3

2.71

N

(.812 x N) + .273

Example for 10 poles:
A= (.812 x 10) + .273 = 8.39

Safety Cover - Catalog number 08530
Polycarbonate safety covers provide dead-front protection to 62000 and 63000 series
power distribution blocks. One cover is needed for each pole (1-pole block requires 1
cover, 3-pole requires 3 covers, etc.) Each cover has a test probe hole in the center for
circuit checking and each is marked with the reminder “REPLACE AFTER SERVICING
EQUIPMENT”. To order, simply determine the total number of poles to be protected and
specify the same number of 08530 safety covers. Mounting screws are supplied with
cover. Recommended mounting screws for all 62000-63000 series: #10 (.190” diameter).

End Barrier - Catalog number U09311
Polycarbonate end barriers snap on to PDB Adder blocks to form 1-pole blocks. Use one
barrier per block.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

I5

Intermediate 66000-67000 Series
Catalog Numbers
Ampere rating based on NEC Table 310-16 for 75ºC copper wire.
Primary

Secondary

Wire Range

Openings

Wire Range

Openings

AWG/kcmiL

or Studs

AWG/kcmiL

or Studs

or Stud Size

per Pole

or Stud Size

per Pole

2/0-#14
#2-14

Aluminum

Ampere
Rating

Copper

Short
Circuit

Adder

1-Pole

2-Pole

3-Pole

Adder

1-Pole

2-Pole

3-Pole Current
Rating

1

67050

67051

67052

67053

66050

66051

66052

66053

100kA•

4

67570

67571

67572

67573

66570

66571

66572

66573

100kA•

#2-14

6

67560

67561

67562

67563

66560

66561

66562

66563

100kA•

#2-14

8

67580

67581

67582

67583

66580

66581

66582

66583

100kA•

#6-14

10

67590

67591

67592

67593

66590

66591

66592

66593

100kA•

#10-14*

12

67110

67111

67112

67113

66110

66111

66112

66113

100kA•

350-#6

1

67000

67001

67002

67003

66000

66001

66002

66003

100kA•

2/0-#14

2

67010

67011

67012

67013

66010

66011

66012

66013

100kA•

#2-14

4

67670

67671

67672

67673

66670

66671

66672

66673

100kA•

#2-14

6

67660

67661

67662

67663

66660

66661

66662

66663

100kA•

#2-14

8

67630

67631

67632

67633

66630

66631

66632

66633

100kA•

#6-14

10

67650

67651

67652

67653

66650

66651

66652

66653

100kA•

#10-14*

15

67620

67621

67622

67623

66620

66621

66622

66623

100kA•

500-#4

1

67400

67401

67402

67403

66400

66401

66402

66403

100kA•

4/0-#6

2

67420

67421

67422

67423

-

-

-

-

100kA•

4/0-#10

2

-

-

-

-

66420

66421

66422

66423

100kA•

2/0-#14

4

67410

67411

67412

67413

66410

66411

66412

66413

100kA•

#2-14

6

67460

67461

67462

67463

66460

66461

66462

66463

100kA•

#2-14

8

67430

67431

67432

67433

66430

66431

66432

66433

100kA•

#6-14

10

67480

67481

67482

67483

66480

66481

66482

66483

100kA•

#10-14*

18

67490

67491

67492

67493

66490

66491

66492

66493

100kA•

#350-#6 &

1

#2-14

3

67450

67451

67452

67453

66450

66451

66452

66453

100kA•

#2/0-#14

2

67020

67021

67022

67023

66020

66021

66022

66023

100kA•

#2-14

6

67510

67511

67512

67513

66510

66511

66512

66513

100kA•

#2-14

8

67610

67611

67612

67613

66610

66611

66612

66613

100kA•

#6-14

10

67530

67531

67532

67533

66530

66531

66532

66533

100kA•

#10-14*

15

67550

67551

67552

67553

66550

66551

66552

66553

100kA•

4/0-#10

2

460

-

-

-

-

66520

66521

66522

66523

100kA•

4/0-#6

2

460

67520

67521

67522

67523

-

-

-

-

100kA•

#2-14

6

460

67540

67541

67542

67543

66540

66541

66542

66543

100kA•

3/8-16 x 1

1

310

67250

67251

67252

67253

66250

66251

66252

66253

3/8-16 x 1-1/16

1

380

67220

67221

67222

67223

66220

66221

66222

66223

1/4-20 x 1-1/16

2

380

67240

67241

67242

67243

66240

66241

66242

66243

1/4-20 x 1-5/16

1

155

-

-

-

-

66270

66271

66272

66273

1/4-20 x 1-5/16

1

155

-

-

-

-

66210

66211

66212

66213

3/8-16 x 1-5/16

1

155

-

-

-

-

66200

66201

66202

66203

3/8-16 x 1-1/8

1

400

-

-

-

-

66260

66261

66262

66263

1/4-20 x 1-1/8

2

400

-

-

-

-

66230

66231

66232

66233

(A)

Box to Box

2/0-#14

350-#6

500-#4

#2/0-#14

4/0-#10
4/0-#6

1

1

1

2

2
2

175

310

380

100kA•

350

Box to Stud
350-36

1

500-#4

1

Stud to Stud
1/4-20 x 1-5/16
1/4-20 x 1-5/16
3/8-16 x 1-1/8

1
1
1

*Copper wire only
Stud type connectors are furnished with nuts and washers. Recommended stud torque: (1/4-20) - 72 in.-lbs; (3/8-16) - 228 in.-lbs.
•
Short circuit current rating with correctly sized fuse 100kA except adder block. Contact Mersen technical services for fuse type and maximum ampere required.
# Aluminum connectors are rated for 90º C Cu/AL wire, copper connectors are rated for 75º C Cu wire.

I6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Intermediate 66000-67000 Series
Dimensions

Number

Dimension A

of Poles

(Inches)

Adder

1.64

1

1.94

2

3.57

3

5.20

N

(1.635 x N) + .3

Example for 10 poles:
A= (1.635 x 10) + .30 = 16.65 inches

Polycarbonate safety covers provide dead-front protection
for 66000 and 67000 series power distribution blocks. One

Properties of Materials Used in
Power Distribution Blocks
ASTM

Glass Filled

Test

Polycarbonate

D792

1.21

D256

4-6

psi

D790

13,200

EQUIPMENT.” Mounting screws are supplied with cover.

Flexural Modulus

psi

D790

325,000

To order, simply determine the total number of poles to be

Tensile Strength

psi

D638

9,000

Compressive Strength

psi

D695

12,500

Water Absorption

24 hrs-%

D570

.15

Hardness

Rockwell

D785

M-85

• 60Hz, 25°C, s/t

vpm

D149

425

• 60Hz, 25°C, s/s

vpm

D149

425

• 60Hz-dry

D150

3.01

• 1Hz-dry

D150

2.96

ohm-cm

D257

>10

°F

D648

270

cover is needed for each pole (1-pole block requires 1

Property

cover, 3-pole requires 3 covers, etc.) Each cover has a test

Specific Gravity

probe hole in the center for circuit checking and each is

IZOD

ft-lb/in

marked with the reminder “REPLACE AFTER SERVICING

Flexural Strength

protected and specify the same number of 08570 safety
covers. Recommended mounting screws for all 66000-67000
series: #10 (.190 diameter).

End Barrier - Catalog No. U09705
Polycarbonate end barriers snap on to PDB Adder blocks to
form 1-pole blocks. Use one barrier per block.

Units

I

Safety Cover - Catalog No. 08570

Dielectric Stength

Dielectric constant

Volume resistivity
Heat deflecting
(°F@264 psi)
Flammability (UL 94)

16

94 V-O

Note: Above data represents approximate values and are for
reference only.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

I7

Large 68000-69000 Series
Catalog Numbers - 68000 and 69000 Series
Ampere rating based on NEC Table 310-16 for 75ºC copper wire.
Primary

Secondary
Openings

Wire Range

Openings or Wire Range

AWG/kcmiL

Studs per

AWG/kcmiL

or Studs

or Stud Size

Pole

or Stud Size

per Pole

2/0-#14

6

#4-14

12

#10-14*

20

500-#4
350-#6

Aluminum

Ampere
Rating
(A)

Copper

Short
Circuit

Adder

1-Pole

2-Pole

3-Pole

Adder

1-Pole

2-Pole

3-Pole

Current
Rating

Box to Box

350-#6

500-#4

600-#2

1000-250

#4-14
2/0-#14

350-#6

500-#4

I8

1

1

1

1

2
2

2

2

69170

69171

69172

69173

68170

68171

68172

68173

100kA•

69150

69151

69152

69153

68150

68151

68152

68153

100kA•

69630**

69631**

69632**

69633** 68630** 68631**

68632**

68633**

1

69050

69051

69052

69053

68050

68051

68052

68053

100kA•

2

69060

69061

69062

69063

68060

68061

68062

68063

100kA•

4/0-#6

4

69510**

69511**

69512**

69513**

-

-

-

-

4/0-#10

4

-

-

-

-

68510** 68511**

68512**

68513**

2/0-#14

6

69070

69071

69072

69073

68070

68071

68072

68073

100kA•

#4-14

12

69080

69081

69082

69083

68080

68081

68082

68083

100kA•

600-#2

1

69640

69641

69642

69643

68640

68641

68642

68643

100kA•

1000-250

1

69000

69001

69002

69003

68000

68001

68002

68003

100kA•

500-#4

2

69010

69011

69012

69013

68010

68011

68012

68013

100kA•

350-#6

2

69020

69021

69022

69023

68020

68021

68022

68023

100kA•

4/0-#6

4

69300**

69301**

69302**

69303**

-

-

-

-

4/0-#10

4

-

-

-

-

68300**

68301**

68302**

68303**

2/0-#14

6

69030

69031

69032

69033

68030

68031

68032

68033

#2-14

10

69530**

69531**

69532**

69533**

68530**

68531**

68532**

68533**

#4-14

12

69040

69041

69042

69043

68040

68041

68042

68043

100kA•

#4-14

12

69180

69181

69182

69183

68180

68181

68182

68183

100kA•

#4-14

12

69160

69161

69162

69163

68160

68161

68162

68163

100kA•

#10-14*

20

69600

69601

69602

69603

68600

68601

68602

68603

100kA•

350-#6

2

69120

69121

69122

69123

68120

68121

68122

68123

100kA•

4/0-#6

4

69320**

69321**

69322**

69323**

-

-

-

-

4/0-#10

4

-

-

-

-

68320**

68321**

68322**

68383**

2/0-#14

6

69130

69131

69132

69133

68130

68131

68132

68133

100kA•

#4-14

12

69140

69141

69142

69143

68140

68141

68142

68143

100kA•

500-#4

2

69090

69091

69092

69093

68090

68091

68092

68093

100kA•

4/0-#6

4

69310

69311

69312

69313

-

-

-

-

4/0-#10

4

-

-

-

-

68310

68311

68312

68313

2/0-#14

6

69100

69101

69102

69103

68100

68101

68102

68103

100kA•

#4-14

12

69110

69111

69112

69113

68110

68111

68112

68113

100kA•

-

600-#2

2

#14-4 & 3/0-#10

4

2

500-#4

4

3

600-#2

3

#6-14

30

#6-14 &

22

600-#2

2

1000-250
600-#2

310

380

420

545

170
350

620

760

69650

69651

69652

69653

-

-

-

69540

69541

69542

69543

68540** 68541**

68542**

68543**

1090

-

69561**†

-

-

-

68561**†

-

-

1260

-

69331**†

-

-

-

-

-

-

-

69191**†

-

-

-

68191**†

-

-

840

500-#4

4

2/0-#14

4

-

69521**†

-

-

-

68521**†

-

-

600-#2

4

600-#2

4

1680

-

69341**†

-

-

-

-

-

-

500-#4

3

4/0-#10

6

1140

-

-

-

-

-

800011**†

-

-

500-#4

7

500-#4

7

2660

-

-

-

-

-

800061***

-

-

500-#4

3

2/0-#14

8

1140

-

900061**†

-

-

-

-

-

-

500-#4

4

500-#4

4

1520

-

900071**†

-

-

-

800031**†

-

-

500-#4

4

2/0-#12

6

1050

-

900121†

-

-

-

800121**†

-

-

100kA•

100kA•

1520

*Copper wire only				**Not UL Recognized or CSA Certified		 ***These pole blocks are triple width (7.81”)
	†These 1 pole blocks are double width (5.31”)
•
Short Circuit current rating with correctly sized fuse 100kA except adder block. Contact Mersen technical services for fuse type and maximum ampere required.
# Aluminum connectors are rated for 90º C Cu/AL wire, copper connectors are rated for 75º C Cu wire.	 							
		

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Large 68000-69000 Series
Catalog Numbers - 68000 and 69000 Series (Continued)
Ampere rating based on NEC Table 310-16 for 75ºC copper wire.
Primary

Secondary
Openings

Wire Range

Openings Wire Range

AWG/kcmiL

or Studs

AWG/kcmiL

or Studs

or Stud Size

per Pole

or Stud Size

per Pole

500-#4

1

3/8-16 x 1

500-#4

2

3/8-16 x 1

2

1000-250

1

1/2-13 x 1-3/16

1

3/8-16 x 1

2

2/0-#14
#4-14
2/0-#14

4

Aluminum

Ampere
Rating
(A)

Copper

Adder

1-Pole

2-Pole

3-Pole

Adder

1-Pole

2-Pole

3-Pole

Box to Stud
1

Cu 380

69210

69211

69212

69213

68210

68211

68212

68213

2

Al 310

69270

69271

69272

69273

68270

68271

68272

68273

-

69221

69222

69223

-

-

-

-

Cu 545

69280

69281

69282

69283

68280

68281

68282

68283

Al 445

69240

69241

69242

69243

68240

68241

68242

68243

4

545

69260

69261

69262

69263

-

-

-

-

12

545

69290

69291

69292

69293

-

-

-

-

1000

-

-

-

-

68260

68261

68262

68263

Cu 380
Al 310

1/2-13 x 1

1

#4-14

12

1000

-

-

-

-

68290

68291

68292

68293

500-#4

4

3/8-16 x 1

4

1520

-

900091†

-

-

-

-

-

-

1

1/2-13 x 1-3/8

1

400

-

-

-

-

68220**

68221**

68222**

68223**

Stud to Stud
1/2-13 x 1-3/8

	
*Stud
type connectors are furnished with nuts and washers. Recommended stud torque: (3/8-16) - 228 in.-lbs; (1/2-13) - 496 in.-lbs.
**Not UL Recognized or CSA Certified
† These 1 pole blocks are double width (5.31”)
# Aluminum connectors are rated for 90º C Cu/AL wire, copper connectors are rated for 75º C Cu wire.	

Number

Dimension A

of Poles

(Inches)

Adder

2.50

1

2.81

2

5.31

3

7.81

N

(2.50 x N) + .31

I

Dimensions – 68000 and 69000 Series Power Distribution Blocks

Example for 10 poles:
A= (2.50 x 10) + .31 = 25.31 inches

Safety Cover - Catalog No. 08590
Polycarbonate safety covers provide dead-front protection to 68000 and 69000 series
power distribution blocks. One cover is needed for each pole (1-pole block requires 1
cover, 3-pole requires 3 covers, etc.) Each cover has a test probe hole in the center for
circuit checking and each is marked with the reminder “REPLACE AFTER SERVICING
EQUIPMENT”. Mounting screws are supplied with cover. To order, simply determine
the total number of poles to be protected and specify the same number of 08590 safety
covers. Recommended mounting screws for all 68000-69000 series: 1/4” (.250 dia.). For

08590 cover and 69092 PDB with
2-08590 covers installed

double wide blocks use 08592W safety cover.

End Barrier - Catalog No. U09911
Polycarbonate end barriers snap on to PDB Adder blocks to form 1-pole blocks. Use one
barrier per block.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

I9

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Circuit Protection Accessories
You maintain the circuit. We’ll maintain an inventory of accessories to help.

Your problem:
that make your

J

job easier add up.
Maybe it’s having

Circuit Protection
Accessories

the right fuse

• Box Covers......................................... J2

puller, so your

• Fuse Reducers................................... J3

people don’t put
themselves at risk
by “improvising”

• Fuse Pullers, Clip Clamps.................. J4
• Trigger® Indicator................................ J5

during fuse changeouts. Or maybe you’re an OEM designer or

• Shawmut Trigger®.............................. J5

specifying engineer, and that circuit protection problem you’ve

• Trigger® Actuator................................ J5

been wrestling with would disappear if fuses came with a special
gadget that . . .
Our solution: Look no further than Mersen’s line of Circuit
Protection Accessories. Cabinets, box covers, reducers, pullers,
blown-fuse indicators, add-on switches . . . they’re all here. In
stock. Under one roof. And ready to meet your circuit protection
system maintenance needs — or help you solve specialized

• Blown Fuse Indicators........................ J6
• Add-on Switches................................ J6
• IL Indicator.......................................... J6
• PSC Microswitches............................ J7
• Protistor® Microswitches................... J10
• Point of Sale Displays...................... J12

design problems.
Want more information fast? For more technical or applicationspecific information, please call our Circuit Protection Accessories
experts, at 978-462-6662; 416-252-9371 in Canada; or visit our
website at us-ferrazshawmut.mersen.com.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

J

The little things

Box Covers
Mersen box covers fit all standard size boxes with a variety of plug fuse, switch
and receptacle combinations. They provide easy access to local protection and
control of 125V motors and other equipment. Long life corrosion-protected steel
bases.

Catalog Numbers
Catalog

Box Cover Features

To Mount On:

COU

Edison-Base Fuse Holder

2-1/4” Handy Box

COW

Edison-Base Fuse Holder

2-3/4” Switch Box

COX

Edison-Base Fuse Holder

4” Octagon Box

COY

Edison-Base Fuse Holder

4” Square Box

CRU

Edison-Base Fuse Holder and Grounding Receptacle

2-1/4” Handy Box

CRW

Edison-Base Fuse Holder and Grounding Receptacle

2-3/4” Switch Box

CRX

Edison-Base Fuse Holder and Grounding Receptacle

4” Octagon Box

No.

Edison-Base Fuse Holder

CRY

Edison-Base Fuse Holder

2-1/4” Handy Box

and Single Pole Switch

CSW

Edison-Base Fuse Holder and Single Pole Switch

2-3/4” Switch Box

CSX

Edison-Base Fuse Holder and Single Pole Switch

4” Octagon Box

CSY

Edison-Base Fuse Holder and Single Pole Switch

4” Square Box

COY-B

2 Edison-Base Fuse Holders

4” Square Box

CSY-L

Edison-Base Fuse Holder and Single Pole Switch and Pilot Light

4” Square Box

CSY-RL

Edison-Base Fuse Holder Single Pole Switch and Pilot Light

4” Square Box

CCY

Edison-Base Fuse Holders and 2 Single Pole Switches

	4” Square Box

CKA

2 Edison-Base Fuse Holders & 250V Grounding Receptacle

	4-11/16” Square Box

CTY

2 Edison-Base Fuse Holders	and one 2-Pole Switch

	4” Square Box

Rating:

Approvals:

Volts	

•• UL listed

: 125V (AC)

COW

COX

COY

CRU

CRW

CRX

CRY

CSU

CSW

CSX

CSY

COY-B

CSY-L

CSY-RL

CKA

CTY

4” Square Box

and Grounding Receptacle

CSU

COU

Amps	 : 15A

CCY

J2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fuse Reducers
Mersen fuse reducers allow the use of lower rated fuses in existing equipment
having clips with higher ampere ratings. The use of closer rated time-delay fuses can
improve circuit protection. For example, renewable or one-time fuses feeding a motor
can be replaced with fuses sized closer to the motor nameplate current. Non-rejection
reducers will allow Class H, K or R fuses to fit Class H or K clips. Rejection-type
reducers will allow only Class R fuses to fit Class R clips or only Class J fuses to fit
Class J clips. Class J fuse reducers are not for bolt on applications.

Catalog Numbers
Catalog Number
Class H & K

Class R

Class J

(Non-rejection)

(Rejection)

(Rejection)

Description

250V
632

R632

-

Allows 30A fuse to fit 60A clips

132

R132

-

Allows 30A fuse to fit 100A clips

162

R162

-

Allows 60A fuse to fit 100A clips

Ratings:

262

R262

-

Allows 60A fuse to fit 200A clips

	

212

R212

-

Allows 100A fuse to fit 200A clips

	

412

R412

-

Allows 100A fuse to fit 400A clip

	

422

R422

-

Allows 200A fuse to fit 400A clips

612

R612

-

Allows 100A fuse to fit 600A clips

622

R622

-

Allows 200A fuse to fit 600A clips

642*

R642*

-

Allows 400A fuse to fit 600A clips

636

R636

J636

Allows 30A fuse to fit 60A clips

162

R162

J136

Allows 30A fuse to fit 100A clips

166

R166

J166

Allows 60A fuse to fit 100A clips

-

J236

Allows 30A fuse to fit 200A clips

266

R266

J266

Allows 60A fuse to fit 200A clips

212

R212

J216

Allows 100A fuse to fit 200A clips

412

R412

J416

Allows 100A fuse to fit 400A clips

422

R422

J426

Allows 200A fuse to fit 400A clips

612

R612

J616

Allows 100A fuse to fit 600A clips

622

R622

J626

Allows 200A fuse to fit 600A clips

642*

R642*

J646

Allows 400A fuse to fit 600A clips

Volts	

: for 250 and 600V Class 	
H, K and R fuses
: for 600 Volt Class J 	
fuses

Amps	 : 30 to 600A
Tested to 200,000A

-

J

600V

Approvals:
•• UL Listed Guide No. IZZR 	
•• CSA Certified

*Not a pair; rejection end piece only.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

J3

Fuse Pullers/Clip Clamps
Plastic Fuse Pullers
Mersen plastic fuse pullers are fully insulated, made of high-dielectric, reinforced
plastic with notched handles to provide a safe grip. Stronger and more durable than
fiber pullers, they are permanently marked with the recommended fuse ampere
range. Yellow color for safety.

Catalog Numbers
Catalog No.
34-001G

Description

Use with Fuses

Size

Length (in)

Ampere

small

5

0-30

34-002G

pocket

7-1/2

34-003G

large

11-3/4

Volts

Diameter (in)

32-250

9/32-1/2

250

0-100

-

600

31-600

250

31-400

600

-

Plastic Fuse Clamps
Mersen fuse clip clamps are used to clamp fuse clips together onto a fuse ferrule or
blade. An easy twist of the cap tightens the jaws against the clip, preventing heating
by reducing resistance at the point where fuse and clip make contact. This helps
prevent loss of spring tension due to annealing from overheating.

Catalog
Numbers
	
Catalog No.

Use with Fuse Clips
Type

Ampere

Volts

32-001G

Ferrule

30

250

32-002G

Ferrule

60

250

32-002G

Ferrule

30

600

32-003G

Ferrule

60

600

32-004G

100

32-005G

200

32-006G*

knife blade

250
or

400

32-007G

600

600

Weight (ounces)

2

2
2
8
8

* Wide jaws permit clamping split clips.

Nylon Fuse Pullers
Mersen nylon fuse pullers are fully insulated, made of high-dielectric, high impact
nylon with no-slip handles and protective finger stops for greater safety when inserting
fuses. Yellow color for safety.

Catalog Numbers
Catalog No.
34-015G
34-016G

J4

Description

Use with Fuses

Size

Length (in)

Ampere

Volts

small

5

0-30

250

0-100

250

0-60

600

medium

7-1/4

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Blown Fuse Indicators
Trigger® Indicator
The Trigger Indicator (catalog number suffix TI) is available on many blade type
fuses, primarily Form 101 semiconductor fuses and some Class L fuses. The TI
allows blown fuses to be identified visually, eliminating the need for resistance or
continuity testing.

Shawmut Trigger®
The Shawmut Trigger Indicator is a field-mountable blown-fuse indicator which is
wired in parallel with the fuse to be monitored. The striker pin exerts a static force of
one pound and may be used to actuate a switch. It is available in 130 volt (TI-130),
600 volt (TI-600), and 1500 volt (TI-1500) ratings. The TI-600 Trigger is a UL Listed
accessory. The Shawmut Trigger is not a fuse and should only be used in parallel with
fuses rated 70A or higher. To mount the Trigger, use two midget fuse clips (for 13/32”
diameter fuses) found in the Fuse Clip section.

Catalog Numbers
Volts

Length A-In.

TI-130

0-130

2

TI-600

0-600

2

TI-1500

0-1500

3-1/2

J

Cat No.

Trigger® Actuator
The Trigger Actuator (catalog number suffix TA) has two functions and is an option
available on many Amp-Trap® fuses. First, it provides visual indication of an open fuse
and second, it provides a mount for an Add-On-Switch (AOS-) which can indicate a
blown fuse via a signal light or initiate appropriate control action. The Trigger Actuator
has no measurable I2t or arc voltage effect on fuses rated 65A or higher. It will add 2 to
5 amperes of long term rating and requires a minimum circuit voltage of 5 to 10 volts to
activate.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

J5

Blown Fuse Indicators
Add-On Switch
Add-On-Switches contain one single-pole double-throw contact rated 4 amperes
resistive and 1 ampere inductive at 250V AC maximum. Two versions of the AddOn-Switch are available. Catalog number AOS-S has screw terminals.
Catalog number AOS-Q accommodates push-on connectors.

IL Indicator
The “IL” indicator, developed from proven designs, provides a blown fuse indication
system which does not sacrifice the excellent I2t characteristics of Mersen fuses.
Its low voltage design requires just 0.9 volts to activate the indicator, thus insuring
reliable fuse performance under all conditions. The red pop up button is located
in the center of the fuse body for ease of visibility and optimum voltage isolation.
Interference with busbar and cable connection is significantly less than other designs.
The addition of the “IL” indicator provides blown fuse indication on virtually all Mersen
fuses. Optional auxiliary microswitches for remote signaling are also available for use
with the “IL” indicator.

Features/Benefits:

Highlights:

•• Visual indication or remote

•• Low voltage design
•• Center location

signaling
•• Optional auxiliary microswitches

•• Rugged construction

Approvals:

•• Same size for all fuses

•• Proven reliability

•• UL Recognized

•• Retains optimum performance

•• AC or DC

•• Operation at all times above 0.9
volts
For blown fuse indication on general purpose fuses, please consult factory.

J6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Microswitches & Studs
Features/Benefits:
•• Microswitch systems adapted to the following fuses:
	

- PSC sizes 30, 31, 32, 33 / 70, 71, 72, 73

	

- Blade-type PSC (PA) sizes 0-1, 2-3 / 70, 71, 72, 73

	

- PSC sizes 000 / 00

•• Highly resistant studs offering optimized connection, excellent electrical
contact and high mechanical withstand for stud-style fuses.

Applications Data
Description

Volt
***

Positive
Operating
Volt/
Current

Interrupting Rating

Nature

Non-Inductive Circuit

Inductive Circuit

Rated

of

Current

Current

30V

110V

250V

30V

110V 250V

AC

Impulse

Voltage

Voltage

Withstand Test UIMP
Test

1.2/50

FIRE
Class
UL 94

MS 3V 1-5

1000 V

20 V

10 A

50/60 Hz

10A

10A

10A

10A

10A

10A

8,5 kV*

14 kV**

H.B.

MS 7V 1-5

1500 V

50 mA

10 A

DC

8A

0,4A

.2A

4A

.2A

.1A

12 kV*

20 kV**

H.B.

MS 3V 1-5 BS

1000 V

10 V

3A

50/60 Hz

3A

3A

3A

2A

1A

1A

8,5 kV*

14 kV **

H.B.

MS 7V 1-9 BS

1000 V

10 V

3A

50/60 Hz

3A

3A

3A

2A

1A

1A

8,5 kV*

14 kV **

H.B.

MS 7V 1-5 BS

1500 V

50 mA

3A

DC

3A

0,5A

0,25A

3A

0,2A

0,1A

12 kV*

20 kV**

H.B.

MS 7V 1-9 BS

1500V

10 mA

3A

DC

3A

0,5A

0,25A

3A

0,2A

0,1A

12 kV*

20 kV**

H.B.

MS 3V 1-5 ET

1000V

10 V

3A

50/60 Hz

3A

3A

3A

2A

1A

1A

8.5 kV*

14 kV**

H.B.

MS 7V 1-5 ET

1500V

10 mA

3A

DC

3A

0.5A

-

2A

0.2A

-

12 kV*

20 kV**

H.B.

MS PA 2-5

1500 V

20 V

10 A

50/60 Hz

10A

10A

10A

10A

10A

10A

9 kV*

13 kV**

VO

MS PA 2-5 B2

1500 V

20 V

5A

50 Hz

4A

4A

5A

-

5A

5A

12 kV*

16 kV**

VO

MS 4L 2-5 B2

1000 V

100 mA

5A

DC

-

-

-

-

2A

0,4A

8 kV*

13 kV**

VO

50/60 Hz

10A

10A

10A

10A

10A

10A

DC

8A

0,4A

0,2A

4A

0,2A

0,1A

8 kV*

10 kV**

VO

3.5 kV*

-

H.B.

7.5 kV*

-

H.B.

MS 4L 2-5 B6

1000 V

MC 6,3 GR 2-5N

1000 V

MC 36 GR 2-5

1000 V

20 V
50 mA
20 V
100 mA
20 V
100 mA

10 A
5A
5A

50/60 Hz

-

5A

3A

-

3A

2A

DC

4A

0.4A

-

3A

0.4A

-

50/60 Hz

-

5A

5A

-

5A

5A

DC

4A

0.4A

-

2A

0.4A

-

J

AC

* 	 Between power circuit and microswitch terminals as per IEC 60 and 694 and NFC 64010 (50/60 Hz 1
min. duration in dry air)
** 	 Between power circuit and microswitch terminals Uimp: impulse voltage as per IEC 947-1
***	 Between power circuit and microswitch terminals
EACH MICROSWITCH WEIGHS LESS THAN 100 g, THEREFORE NO FUME AND SMOKE GRADE IS
REQUIRED BY NF F 16-102 STANDARD

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

J7

PSC Microswitches
MS 3V Fuse Sizes: 30 - 33
Fuse Size

Description

Ref. No.

Indication Style

Weight (g)

MS 3V 1-5 (fig.1)

X310014

Standard NO-NC

34

30, 31

MS 3V 1-5 BS (3)

X310013

Low Level NO-NC

34

32, 33

MS 3V 1-9 BS (4)

T310011

Low Level NO-NC

44

MS 3V 1-5 ET (fig.3)

R310009

Low Level NO-NC

34

Fig. 1

(3) Same as fig. 1
(4) Same dimensions as fig. 1 but with 2 microswitches side by side
(9) Watertightness class

MS 7V1 Fuse Sizes: 70 - 73
Fuse Size

70, 71
72,73

Description

Ref. No.

Indication Style

Weight (g)

MS 7V 1-5 (fig.4)

J310002

Standard NO-NC

45

MS 7V 1-5 BS (7)

K310003

Low level NO-NC

45

MS 7V 1-9 BS (8)

P310007

MS 7V 1-5 ET (fig.5)

S310010

Double pole NO-NC
low level
Low level NO-NC

Fig. 2

55
55

Fig. 3

(7) Same as fig. 4
(8) Same dimensions as fig. 4 but with 2 microswitches side by side
(9) Watertightness class
Attention: Microswitch systems exclusively designed for Mersen PSC
fuses are fitted with a patented trip-indicator, saving the use of an EDV.

MS PA Fuse Sizes: 0 - 70
Fuse Size

Description

Ref. No.

Indication Style

Weight (g)

1,2,3

MS PA 2-5

H210158

OF Standard (fig 7)

32.5

71,72,73

MS PA 2-5B2

C210360

OF Terminal 2.8OF

27

70

MS PA 2-5

T210398

Standard (fig 7)

31

Fig. 4

Exclusive “MS PA” indication systems are automatically resettable

Fig. 5

Fig. 7

J8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fig. 8

PSC Microswitches
MS Indication System for 000 & 00 Fuses
as per DIN 43653 and DIN 43620
Terminals
Automatically resettable, these microswitch systems indicate
fuse presence (PRES) and proper mounting. In case of
improper mounting or fuse melting, terminals 1-4 closed.

Catalog Number

Reference No.

Weight (g)

MS 4L 2-5 B6 + PRES (fig. 1) (1)

F210156C

30

MS 4L 2-5 B2 + PRES (fig. 2) (2)

G210157C

26

(1) 6.3mm Clips
(2) 2.8mm Clips

Fig. 2

J

Fig. 1

MC Indication System for BS 88-4
Blown Fuse Trip-Indicator

Catalog Number
MC 6,3 GR 2-5 N
with external trip-indicator

Catalog Number

Reference No.

Weight (g)

Y 310015

10

Reference No.

Weight (g)

P092496

10

MC 36 GR 2-5 for British standard
fuses with internal indicator 27
and 36

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

J9

Protistor® Fuse Microswitches
Microswitch systems for round and square-body fuses (not
for PSC fuses)
The Protistor fuse microswitch is a remote signaling system designed to fit on round
and square body Protistor fuses (not for PSC fuses) that are equipped with
microswitch support. It indicates fuse status and has a manual reset feature.

Features/Benefits:
•• Remote signaling systems for fitting on Mersen fuses equipped with microswitch
support
•• Indication of fuse status
•• Manual reset
•• Standard and low current models with different insulation ratings
•• Watertight types for use in corrosive atmospheres

Characteristics
AC or DC
Type

Catalog

Insulation

Number

Voltage
Rating Ui (V)

Standard

Low Level

Watertight
IP 50

MC3E 1-5N

1250V

AC Voltage
Withstand
Test (.)
15 kV

MCR3E 1-5N

2200V

20 kV

MC3E 1-5NBS

1250V

15 kV

MC3E 1-9NBS

1250V

15 kV

MCR3E 1-5NBS

2200V

20 kV (1)

MCR3E 1-9NBS

2200V

23 kV (2)

MC2R3E 1-5BS

6000V

24 kV (1)

MC2R3E 1-9NBS

6000V

26 kV (2)

Impulse

Positive

Voltage Test

Operating

Current

Uimp 1,2/50

Min. Voltage /

Rating

hs (..)

Min. Current

20 kV

20 V

30 kV

50 mA

5A

20 kV
10 V
30 kV

10 mA

Non-indicating

Indicating Circuit

Circuit

L/R=25ms

Current
30V

110V

250V 30V

50/60 Hz

10 A

10 A

7A

DC

5A

0.5 A

50/60 Hz

3A

3A

3A

DC

3A

0.5 A

50 Hz

3A

DC

0.5A

250V
6A

1.6 A

0.3A

2A

1A

1A

0.25 A 3 A

0.2 A

0.1 A

3A

1A

1A

3A

40 kV

MC3E 1-5NET

1250V

32 kV (3)

16 kV

MCR3E 1-5NET

2200V

11 kV

30 kV

MC2R3E 1-5NET

6000V

20 kV (1)

40 kV

10 V
10 mA

3A

Catalog numbering system: MC3E 1-5 single pole microswitch - MC3E 1-9 double pole microswitch - MCR,
MC2R reinforced insulation microswitch
* Between power circuit and microswitch terminals as per IEC 60 and 694 and NFC 64010 (50/60 Hz 1 min.
duration in dry air)
** Between power circuit and microswitch terminals Uimp: impulse voltage according to IEC 947-1
***Between power circuit and microswitch terminals
EACH MICROSWITCH WEIGHS LESS THAN 100g, THEREFORE NO FUME AND SMOKE GRADE IS REQUIRED BY NF F16-102 STANDARD
(1) for short body fuses (sizes 30 - 31 - 32 - 33 - 70 - 71 - 72 - 73 - 83 - 84) Except PSC
(2) for sizes 100 - 91 - 92 - 93 - 94 - 123 - 124 fuses and longer
(3) for sizes 171 - 172 - 173 - 174 fuses and longer

J10

100V

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

0.2 A

Protistor® Fuse Microswitches
Remote Signaling with 1250 V AC/DC Insulation Voltage
Quantity of NO-NC
separated circuits

Contact

Catalog

Ref.

Weight

Number

Number

(g)

Pack.
(1)

1

standard

MC3E 1-5N

D310020

39.5

3

1

low level

MC3E 1-5NBS

E310021

39.5

3

2

low level

MC3E 1-9NBS

F310022

45.7

3

1

watertight

MC3E 1-5NET

L310027

40.2

3

Remote Signaling with Insulation Voltage up to 2200 V AC/DC
Catalog

Ref.

Weight

separated circuits

Contact

Number

Number

(g)

Pack.

1

standard

MCR3E 1-5N

G310023

51.7

1

1

low level

MC3RE 1-5NBS

P310030

51.7

1

2

low level

MCR3E 1-9NBS

H310024

58.0

1

1

watertight

MCR3E 1-5NET

Q310031

52.5

1

(1)

J

Quantity of NO-NC

Remote Signaling with Insulation Voltage up to 6000 V AC/DC
Quantity of NO-NC
separated circuits

Contact

Catalog

Ref.

Weight

Number

Number

(g)

Pack.
(1)

1

low level

MC2R3E 1-5NBS

J310025

64.0

1

1

watertight

MC2R3E 1-5NET

N310029

64.8

1

2

low level

MC2R3E 1-9NBS

K310026

70.3

1

Electrical diagram of each microswitch circuit

Non-blown fuse
Microswitch ON

Blown fuse
Microswitch OFF

NOTE (2): The 26.4 dimension is the same with 1 or 2 separated circuits NO-NC.
Tests with sine vibrations carried out at ambient with scanning of the three main holder axes.
Spectrum:	
1st segment (2 to 16 Hz) constant trip		
x = 5 mm peak.
	
2nd segment (16 to 250 Hz) constant acceleration	 y + 5 g peak	

All of these signaling systems are resettable
and fitted with silver-plated 3-terminal
microswitch C, NO and NC. The C terminal
is on the top and connection is made via
6.35 mm clips except for watertight models
whose clips are 4.8 mm wide

Exponential scanning speed: 1 octave per minute.
Duration: 2 hours per axis.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

J11

Point of Sale Displays
FS-POP Free-Standing Floor Display
Mersen’s point of sale display brings best selling fuses within easy reach while
promoting a self service environment. This unit not only acts as a silent efficient
salesperson, but also as an eyecatching reminder to buy. The FS-POP consists of:
metal gondola frame, slatwall, appealing header sign with cross reference guide,
adjustable bins in practical sizes including, (12) standard, (6) wide and (6) large and
bin labels for trouble-free identification. Instructions for assembly are included with
each display.
Standard Bins (White): 5.11 (l) x 5.51 (w) x 3.81 (h) inches.
Wide Bins (White): 5.11 (l) x 11.42 (w) x 3.81 (h) inches.
Large Bins (Orange): 10.83 (l) x 11.0 (w) x 6.70 (h) inches.
*FS-POP is shipped unassembled with instructions included to minimize risk
of products being damaged during shipment.

MFD / MFD300
The miniature fuse display, MFD, is a compact and organized solution to hold only
the most popular glass fuses available. Order with or without fuses. The display can
hold up to 300 fuses and is made from clear plastic which contains individual slots for
supporting standard glass fuse packages. It is wall mountable. Included with the MFD
is a paper insert with company logo and cross reference list. Order the MFD fully
stocked with catalog number MFD300.

GSMR
The Midget and Class CC fuse rack holds 400 fuses and is an automatic feeding
system for standard 10 packs of midget and Class CC fuses. It is peg board and
slatwall mountable.

GSGFD
The GSGFD glass fuse display rack gives high visibility to fuses at the point of
purchase. The GSGFD consists of a sturdy metal display rack with wall mounting
hardware, 48 slots (each holds 12 standard 5-pack boxes for a possible display total
of 576 boxes or 2,880 glass fuses), an attractive header sign, and a laminated glass
fuse cross reference guide for quick and easy selection. The dimensions are 12.5 (w)
x 29.5 (h) x 4 (d) inches.

GSFC / GSFC-M
The Spare Fuse Cabinet provides dedicated storage space for spare fuses. It is
made of heavy duty all-welded steel construction with primed and painted gray finish
offering a good appearance and easy maintenance. A positive latching handle with
cylinder lock and two keys will prevent unauthorized access. It comes in two sizes:
the GSFC is 24 (w) x 36 (h) x 12 (d) inches (6 cubic feet) or the GSFC-M is 18 (w) x
24 (h) x 13 (d) inches (3.25 cubic feet).

J12

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Disconnect Switches
The safest way to switch power on and off in your industrial control panels.

Your problem:
You need a range
of disconnect
switches for your
industrial control
requirements
ranging from

K

Disconnect Switches

• UL508 Non-Fused Load Break
Switches, FSLBS............................... K2
• UL98 Non-Fused Load Break

“Service Entrance
Rated” to motor isolation. You
need DIN-rail and direct mountable disconnect switches that
conform to today’s “finger-safe” IEC standards. You need a range
of handles, shafts and accessories to select from.
Our solution: Mersen offers an extensive line of compact UL98

Switches, FSSC, SX, SXDC, SC....... K5
• UL98 Fusible Disconnect
Switches, FB Series........................ K18
• Enclosed Disconnect Switches....... K31
• Fusible Shunt Trip (Engineered)
Switches.......................................... K37

fusible and non-fusible disconnect switches ranging from 30
to 1200A. We also offer a full range of compact UL508 disconnect switches ranging from 16 to 125A. In addition, you can find
handle, shaft and accessory options that you require for all of
your applications.

K

Want more information fast? For more technical or applicationspecific information, please call our Disconnect Switch experts,
at 978-462-6662; 416-252-9371 in Canada; or visit our website at
us-ferrazshawmut.mersen.com.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Load Break Disconnect Switches FSLBS
UL 508 Non-Fused Load Break Switches
The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of
making or breaking loads up to 600V. It is suitable as a motor disconnect. Extremely
compact and robust, these switches have a variety of mounting options including
DIN-rail, base, or door-mounting. A wide assortment of handles, shafts and
accessories are available to accommodate any installation requirement. Both the
toggle and rotary styles have a built-in pad-lockable hasp and the integrated box
terminals are finger-safe to IP-20. Utilizing a patented, innovative design, the FSLBS
can be actuated from the front or either side.

Highlights:

Applications:

•• Terminals rated for 2 wires!

•• On/Off switching and disconnect

•• Front or side operation

applications in circuits up to 600V,

•• Padlockable

80A on the load side of branch
circuit protection fusing.

•• Compact

•• Motor controller, suitable as motor

•• Robust
•• DIN-rail, base, or door- mounting

disconnect

•• Choice of handles and shafts

•• Motor isolator

•• Side-mount auxiliary contacts and

•• General purpose

additional poles
•• Double-break, silver-plated

Ratings:
Volts	

: 600VAC

Amps	 : 16, 25, 40, 63, and 80A
Suitable as motor disconnect
up to 40hp

contacts

Approvals:
•• UL 508 listed E196672
•• CSA 22.2 #14
•• IEC 60947-3

K2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Load Break Disconnect Switches FSLBS
Catalog Numbers - FSLBS
Ampere Rating
Select a Switch

16A

25A

40A

63A

Toggle

FSLBST16

FSLBST25

FSLBST40

FSLBST63

FSLBST80

Rotary

FSLBS16

FSLBS25

FSLBS40

FSLBS63

FSLBS80

FSHD

FSHD

FSHD

FSHD

FSHD

Black

FSH00BR**

FSH00BR**

FSH00BR**

FSH0BR**

FSH0BR**

Black

FSH00BR4**

FSH00BR4**

FSH00BR4**

FSH0BR4**

FSH0BR4**

Red

FSH00RR**

FSH00RR**

FSH00RR**

FSH0RR**

FSH0RR**

Red

FSH00RR4**

FSH00RR4**

FSH00RR4**

FSH0RR4**

FSH0RR4**

150mm/5.9"

FS150

FS150

FS150

FS150

FS150

200mm/7.9”

FS200

FS200

FS200

FS200

FS200

320mm/12.6”

FS320

FS320

FS320

FS320

FS320

NO/NC

FSACNONC

FSACNONC

FSACNONC

FSACNONC

FSACNONC

NO/NO

FSACNONO

FSACNONO

FSACNONO

FSACNONO

FSACNONO

4th Pole*

FS4P16

FS4P25

FS4P40

FS4P63

FS4P80

Neutral Pole* (not switched)

FSNP40

FSNP40

FSNP40

FSNP80

FSNP80

Ground Pole* (not switched)

FSGP40

FSGP40

FSGP40

FSGP80

FSGP80

Terminal Shrouds

FSTS40

FSTS40

FSTS40

FSTS80

FSTS80

Door Mounting Kit

FSDMK

FSDMK

FSDMK

FSDMK

FSDMK

Direct Operation

No Shaft Required

Handle
Select a

NEMA 1,

Handle

3R, 12
NEMA 1, 3R,
12, 4, 4X
NEMA 1,

Select a Handle
& Shaft

80A

3R, 12

Thru-door

NEMA 1, 3R,
12, 4, 4X
Select a Shaft

Auxiliary Contacts

Select
Accessories

K

*Consult factory for availability
**Either FSH00xxx or FSH0xxx can be used.

Pre-Break Auxiliary Contacts
Mount directly to the side of the switch. The top contact is pre-break, the
bottom contact makes with the switch. Up to four devices can be added, in any
combination (maximum of two additional poles).

Door Mounting Kit
Allows mounting of the switch to a door or side panel. Utilizing the switch’s side
actuation provides access to the terminal screws, enabling the wiring to be
completed after installation.

Padlocking Capabilities
Switch: 	With the switch in the ‘Off’ position, a hasp can be deployed that will
	

lock the switch in this position.

Handle: The white lever in the center of the handle can be rotated out to reveal 	
	

openings for up to 3 padlocks.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K3

Load Break Disconnect Switches FSLBS
UL and CSA Characteristics - FSLBS
Technical Characteristics

16A

25A

40A

63A

80A

Short circuit current rating at 600 VAC

10kA/65kA

10kA/65kA

10kA/65kA

65kA/50kA

65kA/50kA

Fuse type

J/J

J/J

J/J

J

J

Maximum fuse rating (A)

60/30

60/30

60/30

60/100

60/100

Maximum Horsepower Rating / Max. motor FLA 3 φ
208 VAC

3 / 11A

7.5 / 24A

7.5 / 24A

15 / 46A

15 / 46A

220 - 240 VAC

5 / 15A

7.5 / 22A

7.5 / 22A

20 / 54A

20 / 54A

440 - 480 VAC

10 / 14A

15 / 17A

20 / 27A

40 / 52A

40 / 52A

600 VAC

10 / 11A

20 / 22A

25 / 27A

40 / 41A

40 / 41A

Connection
Solid (AWG)
Stranded (AWG)
Torque

#14 - #10

#14 - #10

#14 - #10

#14 - #10

#14 - #10

2x #12

2x #12

2x #12

2x #12

2x #12

#14 - #4

#14 - #4

#14 - #4

#14 - #1

#14 - #1

2x (#14 - #12)

2x (#14 - #12)

2x (#14 - #12)

2x (#10 - #6)

2x (#10 - #6)

26.5 lb-in/3 Nm

26.5 lb-in/3 Nm

26.5 lb-in/3 Nm

31.1 lb-in/3.5 Nm

31.1 lb-in/3.5 Nm

A300

A300

A300

A300

A300

Auxiliary Contacts
Electrical characteristics

FSLBS Dimensions (Inch/mm)
Rating

AC

F

F1

G

J

M

N

T

16, 25, 40A

4.33 / 110

1.77 / 45

0.59 / 15

2.68 / 68

0.59 / 15

1.18 / 30

2.95 / 75

0.59 / 15

63, 80A

4.33 / 110

2.07 / 52.5

0.69 / 17.5

3.00 / 76

0.69 / 17.5

1.38 / 35

3.35 / 85

0.69 / 17.5

1. Additional Pole - maximum of two, one each side 	
2. Auxilliary Contact - maximum of four, two each side 	

E. Minimum is 1.18"/30mm, maximum is 14.6" /372mm
D. Minimum is 1.18"/30mm, maximum is 9.25" /235mm

16A to 40A Direct operation "Toggle"
1

75
64

8,8 F1
M5

T

F1 8,8

External front operation

64
50,6

36
64
50,6

D

1

G
68

2

6

6
50

K4

T

F1

8,8

50

2

F
M
1J

8,8 F1
M5

F
D
M
J
1
2

D
36
1
2

8,8 F1
F1 8,8
T
T M5

36

ø 71

36
D

81

81

F1
M5

External side operation

E

E

8,8

6

N
AC
ø 71

36

N
AC

36

50

G
68

6

1

G
68

G
68
50

F
M

1

N
AC

1

N
AC

F
M

81
73
64

63A and 80A Direct operation "Rotary"

F1 8,8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Non-Fused Load Break Switches

FSSC, SX, SXDC, SC

UL 98 Non-Fused Load Break Switches
Mersen disconnect switches are extremely durable, manually operated, non-fused
disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect switch technology available. Designed to suit the UL98 or UL489
standard, the switch gives you a product that “makes and breaks” power circuits
on load. The switches are tested and approved for use in demanding applications,
such as “Service Entrance”. Up to 400A, the switches are available with visible
blade contacts. A wide array of handles are available to meet OSHA padlocking
­requirements, NEMA configurations, defeater options and NFPA 79 requirements.

Features/Benefits
•• UL 98 Service entrance rated
•• Front or side operated switches
•• Padlockable
•• Compact

Ratings:

•• Robust
•• DIN-rail, panel or door mounting
•• Lockable, defeatable external handles
•• Side-mounted auxiliary contacts and additional poles available
•• The SXDC switches are rated 600VDC UL and 1000VDC IEC

Highlights:

Applications:

•• Visible blade contacts up to 400 A

•• Service entrance or main panel

•• Line side shrouding supplied with

disconnects up to 600VAC, 1200A

Volts	

: 600VAC / DC

	

: UL and 1000VDC IEC

Amps	 : 30A, 60A, 100A, 200A,
	

400A, 600A, 800A, 	

	

1000A and 1200A

SCCR	 : Up to 200kA with fuses
Suitable as motor disconnect up
to 200hp

•• “Make and break” power circuit
applications on load

automatically re-latch when panel

•• NFPA 79 solutions

door is closed - no tool necessary

•• Photovoltaic

to reset latch
•• External or direct ­operation
handles
•• Flange operation (for use with side
operated switches)
•• Double-break, silver-plated
contacts
•• SX series has flexible terminal
shields that allow for tighter wire
bending

K

switch
•• Defeatable pistol handles

Approvals:
•• All switches meet the
requirements of UL and CSA
•• UL listed guide WHTY, File
E191605 for UL 98 (ratings from
30 A to 1200 A)
•• CSA 22.2 # 4, class 4652-04,
File 703166 (ratings from 30 A to
1200 A)
•• IEC 947-3 CE mark (other IEC
ratings up to 5,000A available
on request, please consult us)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K5

Non-Fused Load Break Switches
Catalog Numbers (amps) - FSSC
Select a Switch
Direct Operation

No Shaft Required

Handle

Select a Handle

FSSC

Compact, UL98
Ampere Rating

30

60

100

FSSC Non-fused Load Break Switch

FSSC30

FSSC60

FSSC100

FSHD3

FSHD3

FSHD3

Handle for Direct Front Operation
Black
Handle for External Front and Side Operation
NEMA Type

IEC

Color

Select a Handle

1, 3R, 12

IP54

Black

FSH0BR

FSH0BR

FSH0BR

& Shaft

1, 3R, 12

IP54

Red/Yellow

FSH0RR

FSH0RR

FSH0RR

1, 3R, 12,4, 4X

IP65

Black

FSH0BR4

FSH0BR4

FSH0BR4

1, 3R, 12,4, 4X

IP65

Red/Yellow

Select a Shaft
Thru-door

FSH0RR4

FSH0RR4

FSH0RR4

150mm/5.9"

FS150

FS150

FS150

200mm/7.9”

FS200

FS200

FS200

320mm/12.6”

FS320

FS320

FS320

Accessories

Select Accessories

Fourth Pole*

FSSC4P30

FSSC4P60

FSSC4P100

Neutral Pole (Unswitched)*

FSSCNP

FSSCNP

FSSCNP

Ground Pole (Unswitched)*

FSSCGP

FSSCGP

FSSCGP

3-pole Terminal Shroud (line and load sides)

FSSCTS

FSSCTS

FSSCTS

1-pole Terminal Shroud (line and load sides)

FSSCTS1

FSSCTS1

FSSCTS1

Auxiliary Contacts, NO and NC

FSACNONC

FSACNONC

FSACNONC

Auxiliary Contacts, both NO

FSACNONO

FSACNONO

FSACNONO

*Consult factory for availlability.







UL and CSA Characteristics



Technical characteristics

30A

60A

100A

Short circuit rating at 480 VAC

100kA

100kA

100kA

Short circuit rating at 600 VAC

100kA

100kA

25kA

Fuse type

J

J

J

Max. fuse rating (A)

30

60

100

220-240 VAC

10 / 28

20 / 54

20 / 54

440-480 VAC

20 / 27

40 / 52

50 / 65

600 VAC

25 / 27

50 / 52

50 / 52






Max. horsepower rating / Max. motor FLA 3 ph

Illustration Overview
1.	
2.	
3.	

Max. horsepower rating / Max. motor FLA single phase
120 VAC

5 / 56

5 / 56

5 / 56

240 VAC

10 / 50

10 / 50

10 / 50

480 VAC

25 / 55

25 / 55

25 / 55

Connection
Solid

1 wire

#12 - #10

#12 - #10

#12 - #10

Stranded

1 wire

#12 - 2/0

#12 - 2/0

#12 - 2/0

A300

A300

A300

Auxiliary Contacts
Electrical characteristic

K6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

4.	
5.	
6.	
7.	
8.	

Direct Handle
Door-interlocked
External Handle
Shaft for External
Operation(includes
collar)
Terminal Shrouds
Switched 4th Pole
Switch body
Unswitched Neutral or
Ground Pole
NO/NC Auxiliary
Contacts

www.barr-thorp.com

Non-Fused Load Break Switches
Front Operated Range 100A to 400A - SX

SX

High HP Rating!

Select a switch

Catalog Numbers
Ampere Rating

Select a switch

100

200

400

3-Pole

SX1003

SX2003

SX4003

4-Pole

SX1004

SX2004

SX4004

S type pistol handle for external front and side operation

Select a handle

NEMA Type

IEC

Color

1, 3R, 12

IP54

Black

HSPBL

Catalog Numbers
HSPBL

HSPBL

1, 3R, 12

IP54

Red / Yellow

HSPRL

HSPRL

HSPRL

1, 3R, 12, 4, 4X

IP65

Black

HSPB4L

HSPB4L

HSPB4L

1, 3R, 12, 4, 4X

IP65

Red / Yellow

HSPR4L

HSPR4L

HSPR4L

Shaft Length (in/mm)
Select a shaft

Catalog Numbers

7.9 / 200

SS200-10

SS200-10

SS200-10

12.6 / 320

SS320-10

SS320-10

SS320-10

15.7 / 400

SS400-10

SS400-10

SS400-10

19.7 / 500

SS500-10*

SS500-10*

SS500-10*

*Not UL

Pistol handle for direct front operation
Color
Black

Catalog Numbers
SXHD

SXHD

SXHD

K

Direct Handle for SX

Options for front & side operation
Catalog Numbers
Terminal lugs for 3-pole (set of 6)

TL200X6

TL200X6

Terminal lugs for 4-pole (set of 8)

TL200X8

TL200X8

TL400X6
TL400X8

1 Auxiliary Contact NO+NC

SXAUX

SXAUX

SXAUX

2 Auxiliary Contact NO+NC

SXAUX2

SXAUX2

SXAUX2

Top Terminal Screen 3-pole

SXTS2T3

SXTS2T3

SXTS4T3

Bottom Terminal Screen 3-pole

SXTS2B3

SXTS2B3

SXTS4B3

Top OR Bottom Terminal Screen 4-pole

SXTS2TB4

SXTS2TB4

SXTS4TB4

Please contact factory for visible blades and/or flange operation.

Note: Do not mount in a vertical position with window on top. Any other orientation is okay.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K7

Non-Fused Load Break Switches SXDC
Front Operated Range 100A to 400A - SXDC

UL listed 600VDC load-break!

Select a switch

Catalog Numbers
Ampere Rating

Select a switch

100

200

400

3-Pole

SXDC1003

SXDC2003

SXDC4003

4-Pole

SXDC1004

SXDC2004

SXDC4004

S type pistol handle for external front and side operation

Select a handle

NEMA Type

IEC

Color

Catalog Numbers

1, 3R, 12

IP54

Black

HSPBL

HSPBL

HSPBL

1, 3R, 12

IP54

Red / Yellow

HSPRL

HSPRL

HSPRL

1, 3R, 12, 4, 4X

IP65

Black

HSPB4L

HSPB4L

HSPB4L

1, 3R, 12, 4, 4X

IP65

Red / Yellow

HSPR4L

HSPR4L

HSPR4L

Shaft Length (in/mm)
Select a shaft

Catalog Numbers

7.9 / 200

SS200-10

SS200-10

SS200-10

12.6 / 320

SS320-10

SS320-10

SS320-10

15.7 / 400

SS400-10

SS400-10

SS400-10

19.7 / 500

SS500-10*

SS500-10*

SS500-10*

*Not UL

Pistol handle for direct front operation
Color
Direct Handle for SX

Black

Catalog Numbers
SXHD

SXHD

SXHD

Options for front & side operation
Catalog Numbers
Terminal lugs (set of 2)

TL200X2

TL200X2

TL400X2

Jumper bars (set of 2, for 3-pole)

SX2J

SX2J

SX4J*

Jumper bars (set of 3, for 4-pole)

SX2J4

SX2J4

SX4J4*

1 Auxiliary Contact NO+NC

SXAUX

SXAUX

SXAUX

2 Auxiliary Contact NO+NC

SXAUX2

SXAUX2

SXAUX2

Top Terminal Screen 3-pole

SXTS2T3

SXTS2T3

SXTS4T3

Bottom Terminal Screen 3-pole

SXTS2B3

SXTS2B3

SXTS4B3

Top & Bottom Terminal Screen 4-pole

SXTS2TB4

SXTS2TB4

SXTS4TB4

*If the application requires a heavy loading of the switch, doubling of the jumper bars may
be necessary.

Note: Do not mount in a vertical position with window on top. Any other orientation is okay.

K8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Non-Fused Load Break Switches SC
Front Operated Range from 600 to 1200A - SC
Catalog Numbers
Ampere Rating

Select a switch

600

800

1000

1200

3-pole

SC600

SC800

SC1000

SC1200

4-pole

SC6004

SC8004

SC10004

SC12004

S type pistol handle for front external operation
Select a handle
Recommended for easier switching

NEMA Type

IEC

Color

1, 3R, 12, 4, 4X

IP65

Black

HSTB4

HSTB4

Catalog Numbers
HSTB4

HSTB4

1, 3R, 12, 4, 4X

IP65

Red / Yellow

HSTR4

HSTR4

HSTR4

HSTR4

Note: Handle is defeatable and is padlockable in the “OFF” position

Select a handle
Recommended for tighter spacing

NEMA Type

IEC

Color

1, 3R, 12

IP54

Black

HSPBEL

HSPBEL

Catalog Numbers
HSPBEL

HSPBEL

1, 3R, 12

IP54

Red / Yellow

HSPREL

HSPREL

HSPREL

HSPREL

1, 3R, 12, 4, 4X

IP65

Black

HSPB4EL

HSPB4EL

HSPB4EL

HSPB4EL

1, 3R, 12, 4, 4X

IP65

Red / Yellow

HSPR4EL

HSPR4EL

HSPR4EL

HSPR4EL

Note: Handle is defeatable and is padlockable in the “OFF” position
Shaft Length (in/mm)

Select a shaft

Catalog Numbers

7.9 / 200

SS200-15

SS200-15

SS200-15

SS200-15

12.6 / 320

SS320-15

SS320-15

SS320-15

SS320-15

15.7 / 400

SS400-15

SS400-15

SS400-15

SS400-15

Note: The small shaft protruding from the switch is 15mm x 15mm. The shaft for the handle is 12 x
12mm. A coupler is included and adapts from 12mm to 15mm.

Pistol handle for direct front operation
Select a handle

Color

Catalog Numbers

Black

HADB5

HADB5

HADB5

HADB5

K

Note: Handle is defeatable and is padlockable in the “OFF” position

Options for front & side operation
Terminal Lugs Kit

Select a handle

Catalog Numbers

Six lugs per kit - for 3-pole switches

TL600

TL800(4)

TL1200

TL1200

Eight lugs per kit - for 4-pole switches

TL6004

TL8004(4)

TL12004

TL12004

Terminal Screen

(1)

3-pole (for line or load side)
4-pole	

(for line or load side)

TS600SC

TS1200SC

TS1200SC

TS1200SC

TS6004SC

TS12004S

TS12004SC

TS12004SC

ACHSC

ACHSC

ACHSC

ACHSC

AC3

AC3

AC3

AC3

AC4

AC4

AC4

AC4

SWL01

SWL01

SWL01

SWL01

Auxiliary Contacts
Auxiliary Contacts Holder(2)
1 N / O, 10A, 600VAC snap-on contact block,
A600-Q600, pre-break, late make
1 N / C, 10A, 600VAC snap-on contact block,
A600-Q600, pre-break, late make
Padlocking facility for external operation(3)

(1) Line side Terminal Screen supplied as standard with switch.
(2) ACHSC accommodates up to 4 auxiliary contacts.
(3) Allows to padlock the switch when door of the enclosure is open.
(4) TL1200 or TL12004 also fit if 4 holes are required.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K9

Non-Fused Load Break Switches SX
Technical Characteristics for Front and Side Operation - SX
Catalog Numbers - UL, cUL and CSA
Catalog Numbers

SX1002 / SX1003 / SX1004

SX2002 / SX2003 / SX2004

SX4002 / SX4003 / SX4004

Ampere Rating

100

200

400

Operating voltage

600

600

600
100 / 286

Max Horsepower Rating / Max Motor FLA Current Three-Phase
208 V

25 / 78.5

50 / 150

240 V

30 / 80

79 /192

125 / 312

480 V

75 / 96

150 / 180

250 / 302

600 V

100 / 99

200 / 192

350 / 336

DC 125 V

10 / 76(1)

15 / 55(1)

20 / 148(1)

DC 250 V

15 / 55(2)

15 / 55(2)

50 / 173 (2)

Short circuit rating with fuses (SCCR) kA

200

200

200

Branch circuit fuse type

J

J

J

Max fuse rating (A)

100

200

400

Dimension 3-Pole (front operated switches)
H (in)

6.3

6.3

10.2

W (in)

7.1

7.1

9.05

D (in)

3.72

3.72

4.92

Shaft Size Square (front operated switches)
in

0.4 x 0.4

0.4 x 0.4

0.4 x 0.4

mm

10 x 10

10 x 10

10 x 10

88

88

130

Terminal lugs kit (# lugs per kit)

Optional (6)

Optional (6)

Optional (6)

Wire range AWG (# wire holes per lug)

300 kcmil-#6 (1)

300 kcmil-#6 (1)

250 kcmil-1/0 (2)

Wire tightening torque (lb in)

275 max

275 max

375 max

3-pole switch operating torque (front operation)
(lb in)

(1) 2-pole in series. (2) 3-pole in series.

Catalog Numbers - IEC 947-3
Catalog Numbers

SX1002 / SX1003 / SX1004

SX2002 / SX2003 / SX2004

SX4002 / SX4003 / SX4004

Ampere Rating

A

100

200

400

Rated Insulation voltage Ui (V)

V

1000

1000

1000

Rated impulse voltage (Uimp)

kV

12

12

12

AC-22A

100

200

400

AC-23A

100

200

400

AC-22A

100

200

400

AC-23A

100

200

315

400 V AC

AC-23A

51

100

220

500 V AC

AC-23A

63

140

220

690

AC-23A

90

185

295

Max.peak let through current (gG)

kA peak

17.6

32

40

Minimum Cu cable section

mm2

25

50

185

Minimum Cu bubar section

mm2

-

-

-

Operation Current Ie (A)
400 V AC
690 V AC
Motor Power (kW)

Connection

K10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Non-Fused Load Break Switches SXDC
Technical Characteristics - SXDC
Catalog Numbers - UL, cUL and CSA
Catalog Numbers
SXDC1002, SXDC1003,

SXDC2002, SXDC2003,

SXDC4002, SXDC4003,

SXDC1004

SXDC2004

SXDC4004

Ampere Rating

100

200

400

Operating Voltage - 3P in series

600V DC

600V DC

600V DC

Prospective short-circuit current (rms) with fuses

20kA

20kA

20kA

Type of Fuse

A70P100

A70P200

LDC

Fuse Rating

100

200

400

Height (without shrouds) (in)

6.3

6.3

10.2

Width (in)

7.1

7.1

9.05

Depth (in)

3.7

3.7

4.9

Shaft size (mm)

10 x 10

10 x 10

10 x 10

3-pole switch operating torque (front operation) (lb in)

88

88

130

Terminal lugs kit (# lugs per kit)

Optional (6)

Optional (6)

Optional (6)

Wire range AWG (# wire holes per lug)

300 kcmil-#6 (1)

300 kcmil-#6 (1)

250 kcmil-1/0 (2)

Wire tightening torque (lb in)

275 max

275 max

375 max

Auxiliary Contacts

A300

A300

A300

UL, cUL, and CSA

Dimensions 3-pole

Catalog Numbers - IEC 60947-3, DC-22B
Catalog Numbers
SXDC2002, SXDC2003,

SXDC1004

SXDC2004

SXDC4004

Ampere Rating

160

250

400

Operating Voltage - 3P in series

750V DC

750V DC

750V DC

Operating Voltage - 4P in series

1,000V DC

1,000V DC

1,000V DC

IEC 60947-3, DC-22B

SXDC4002, SXDC4003,

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K

SXDC1002, SXDC1003,

K11

Non-Fused Load Break Switches SC
Technical Characteristics for Front and Side Operation - SC
Catalog Numbers - UL, cUL and CSA
Catalog Numbers

SC600 / SC6004

SC800 / SC8004

SC1000 / SC10004

SC1200 / SC12004

Ampere Rating (A)

600

800

1000

1200

Operating voltage (V)

600

600

600

600

Max Horsepower Rating / Max Motor FLA Current Three-Phase
208 V

150 / 415

200 / 554

200 / 554

200 / 554

240 V

200 / 480

200 / 602

200 / 602

200 / 602

480 V

400 / 447

500 / 590

500 / 590

500 / 590

600 V

350 / 336

500 / 472

500 / 472

500 / 472

DC 125 V

(1)

20 / 148

-

-

-

DC 250 V

50 / 173(2)

-

-

-

Short circuit rating with fuses (SCCR) (kA)

200

100

100

100

Branch circuit fuse type

J

J

J

J

Max fuse rating (A)

600

800

1000

1200

H (in)

12.60

13

13

13

W (in)

11.02

14.64

14.64

14.64

D (in)

5.51

5.51

5.51

5.51

in.

0.59 x 0.59

0.59 x 0.59

0.59 x 0.59

0.59 x 0.59

mm

15 x 15

15 x 15

15 x 15

15 x 15

3-pole switch operating torque (front operation) (lb in)

320

320

320

320

Terminal lugs kit (# lugs per kit)

optional (6)

optional (6)

optional (12)

optional (12)

Wire range AWG (# wire holes per lug)

600 kcmil-#2 (2)

600 kcmil-#2 (3)

600 kcmil-#2 (4)

600 kcmil-#2 (4)

Wire tightening torque (lb in)

375

375

375

375

Dimension 3-Pole (front operated switches)

Shaft Size Square (front operated switches)

(1) 2-pole in series. (2) 3-pole in series.

Catalog Numbers - IEC 947-3
Catalog Numbers

SC600 / SC6004

SC800 / SC8004

SC1000 / SC10004

SC1200 / SC12004

Ampere Rating

A

600

800

1000

1200

Rated Insulation voltage Ui

V

1000

1000

1000

1000

Rated impulse voltage (Uimp)

kV

12

12

12

12

AC-22A

630

800

1000

1200

AC-23A

630

800

1000

1000

AC-22A

500

630

630

630

AC-23A

200

400

400

400

400 V AC

AC-23A

355

450

560

560

500 V AC

AC-23A

450

560

560

560

690 V AC

AC-23A

185

400

400

400

Max. peak let through current (gG)

kA peak

48

75

75

75

Minimum Cu cable section

mm2

2 x 150

2 x 185

2 x 240

-

Minimum CU busbar section

mm2

2 x 30 x 5

2 x 40 x 5

2 x 50 x 5

2 x 60 x 5

Operation current Ie (A)
400 V AC
690 V AC
Motor Power (kW)

Connection

K12

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Non-Fused Load Break Switches

FSSC, SX, SXDC

Dimensions (in/mm) for Front and Side Operation
FSSC 30 to 100A
37

100 min.
372 max.
81
64
50,6

30 min.
201 max.
1

78
26
13

1

37

44

2

70

ø 71
88

131,4
189

124,6

2

6

8,8

53

26

26
M5

8,8

26

SX and SXDC 100 to 400A
Overall

Terminal

Ampere dimen.

shrouds

Rating (A)

Switch body

2.65

135

67.5

2.95

166

75

9.05

115

230

H

K

Connection terminal

N

R1

R2

T

U

V

W

Y

Z

AA

CA

8.27

5.31

0.35

0.27

1.97

0.98

1.18

0.43

0.14

1.35

6.3

0.6

210

135

9

7

50

25

30

11

3.5

34.4

160

15

8.26

10.6

7.6

0.35

0.27

2.56

1.77

1.97

0.43

0.2

2.08

10.2

0.8

210

270

195

9

7

65

45

50

13

5

53

260

20

K

128 mm

5.31

6.53

290

4.51

406

4.92 in

400

160

11.4

16

400

6.3

105

230

256

45.6

4.13

55

9.06

180

10.1

94.6 mm

1.8

2.17

107

7.09

77.5

3.72 in

100 - 200

4p.

4.22

3.05

100 - 200

M

4p.

4p.

AD

3p.

J1

3p.

F

3p.

AC

M

J1

F

C

Switch mounting

M
J1

U

Z
Y

1

W

AC
H

AA

N

K

V

CA

R1

R2

T

AD
C

F

Direct Front Operation

External Front Operation

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K13

Non-Fused Load Break Switches SC
Dimensions (in/mm) for Front Operation - SC
600 A
SC600
SC6004

800-1000-1200 A
SC800
SC8004
SC1000
SC10004
SC1200
SC12004

B

C

H

H1

H2

J

J1

K

K1

K2

Y

No. of

Rating

Poles In

mm

In

mm

In

mm

In

mm

In

mm

In

mm

In

mm

In

mm

In

mm

In

mm

In

mm

In

mm

400 A

3P

11.02

280

12.60

320

5.51

140

9.05

230

5.43

138

8.66

220

10.04

255

5

127.5

6.88

175

2.34

59.5

1.10

28

1.85

47

600 A

4P

14.17

360

12.60

320

5.51

140

9.05

230

5.43

138

8.66

220

13.19

335

6.59

167.5

6.88

175

2.34

59.5

1.10

28

1.85

47

3P

14.64

372

13

330

5.51

140

9.05

230

5.43

138

-

-

13.66

347

6.83

173.5

6.88

175

2.34

59.5

1.10

28

1.85

47

4P

19.37

492

13

330

5.51

140

9.05

230

5.43

138

-

-

18.38

467

9.19

233.5

6.88

175

2.34

59.5

1.10

28

1.85

47

800 A 1000 A
1200 A

K14

A

Ampere

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Non-Fused Load Break Switches

FSSC, SX, SXDC, SC

Dimensions (in/mm) for External Front Operation Handles
S type pistol handle
HSPBL
HSPRL
HSPB4L
HSPR4L

HSPBEL

Side operation

HSPREL
HSPB4EL
HSPR4EL

Front operation

HSTB4

Ø3.07
Ø78

2.36
60

HSTR4

K

S type pistol double handle

13.78
350

(1)	 Conventional fixing (from rear): D = 1.22 to 1.45 in / 31 to 37 mm.
	
Fast fixing (external, door closed): D = 1.45 in / 37 mm, fast fixing is acheived with
special clips that avoid drilling for fixation of the handle on the door. Clips are included.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K15

Non-Fused Load Break Switches

FSSC, SX, SXDC, SC

Dimensions (in/mm) from Backplate to Door Distance with Shaft Extension - FSSC, SX, SC
Minimum distance (in / mm)

h

H & C Minimum

All HSP Handles

Dimension

In

mm

FSSC

6

153

SX 100-200A

6

152

SX 400A

8

203

SC 600-1200 A

8.70

221

Jumper Bars - SXDC
12.5

50

12.5

4

12

15

100A and 200A #SX2J

81

Ø11

400A and 200A #SX4J

19

Note: Large size is for heat dissipation.

22.5

65

22.5

5

SX4003

SC600

SC1000

SX4004

SC6004

SC10004

SXDC4003

SC800

SC1200

SXDC4004

SC8004

SC12004

C
L
L = X - 1.71
L = X - 43.5

min. 0.78 in / 20 mm
max. 1.18 in / 30 mm

X

K16

0.76
19.5

L

L = X-0.86
L = X-22

X

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Non-Fused Load Break Switches

SX, SXDC, SC

Dimensions (in/mm) for Terminal Lugs
For use with SX series switches

TL400X

TL200X

1 wire 300kcmil / 0 - #6

2 wire 250kcmil - 1/0

TL 800

TL600: For use with SC 600 (1 lug per terminal)
TL1200: For use with SC 800, 1000 & 1200 (2 lugs per terminal)

For use with SC 800

2 wires 600 MCM-2

3 wires 600 MCM-2

K

TL600 and TL1200

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K17

Fusible Disconnect Switches FB Series
UL 98 Fusible Disconnect Switches
Mersen FB Series disconnect switches are extremely durable, manually operated,
fusible disconnect switches. They employ double break contacts per pole that
ensure complete ­isolation of the fuse when the switch is in the OFF position. With
safety in mind, all fusible disconnect switches are supplied with fuse covers and line
side shrouding as a standard feature. These switches provide the ultimate in short
circuit protection when used with Mersen’s Class CC, J or L fuses.These heavyduty switches are designed with the most up-to-date disconnect fuse and switch
­technology available. Designed to meet the UL98 or UL489 standard, the fusible
disconnect switch gives you the ­product that “makes and breaks” power circuits
under load. They have been tested and approved for use in the most demanding
applications, such as “Service Entrance.” The optional TEST function (up to 400 A)
enables testing of the control circuit ­auxiliaries without switching the main contacts.
This function provides a simple alternative to a ­separately wired push button. A
wide array of handles are available to meet OSHA padlocking requirements, NEMA
configurations, defeater options and NFPA 79 requirements.

Highlights:

Applications:

•• Double break contact per pole up

•• Service entrance or main panel
disconnects up to 600 VAC, 800 A

to 800 A
•• Touch safe covers protect fuse

•• “Make and break” power circuit
applications on load

terminals
•• Service entrance rated

•• Fusible isolation switches

•• Compact footprints

•• NFPA 79 solutions

•• Front and side operated switches
with snap-on auxiliary contact

Recommended fuse usage:

feature

•• FBCC ─ use with ATDR*, ATMR,

•• 14AWG power taps on both line

ATQR

Volts	

: 600VAC, 250VDC

Amps 	 : 30, 60, 100, 200, 400, 	
600, and 800A

	

SCCR	 : Up to 200kA with
	

Class CC, J, or L Fuses

and load sides for control power

•• FBJ ─ use with AJT, A4J, HSJ

Approvals:

transformers or surge protection

•• FBL ─ use with A4BQ, A4BY,

•• All Fusible Disconnect Switch

•• External or direct operation
handles

A4BT

* Recommended for DC application

•• Defeatable pistol handles

switches meet UL & CSA
requirements
•• UL listed guide WHTY, File

automatically re-latch when panel

E191605 for UL 98 (ratings from

door is closed - no tool necessary

30 A to 800 A)
•• UL listed guide WJAZ, File

to reset latch
•• Test positions available up to 400A
•• Padlocking feature as standard on
modular switchgear boxes
•• Modular switch configurations,
special executions on request (5-

E258428 for UL489 (for 30 A
CDT)
•• CSA 22.2 # 4, class 4652-04,
File703166 (ratings from 30 A to
800 A)
•• CSA 22.2 # 5, class 4652-06,

pole, mix ratings…)

File 703166 (for 30 A CDT)

•• Padlockable handle
•• Flange-mounted actuators

K18

Ratings:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

•• IEC 947-3 CE mark

www.barr-thorp.com

Fusible Disconnect Switches FB Series
Front and Side Operated Range from 30 to 60A
Catalog Numbers
Ampere Rating

Select a switch

30

30

2-Pole

30

60

FBJ302X

FBJ602X

3-Pole

FBCC30CDT

FBJ30CDT

FBJ303X

FBJ603X

4-Pole

FBCC30SNCDT

FBJ30SNCDT

FBJ304X

FBJ604X

CC

J

J

J

Fuse class

Selector handle for external front operation

Select a handle

Test

Color

Catalog Numbers

NEMA Type

IEC

1, 3R, 12

IP54

No

Black

HSPB

HSPB

HSPBL

HSPBL

1, 3R, 12

IP54

No

Red / Yellow

HSPR

HSPR

HSPRL

HSPRL

1, 3R, 12, 4, 4X

IP65

No

Black

HSPB4

HSPB4

HSPB4L

HSPB4L

1, 3R, 12, 4, 4X

IP65

No

Red / Yellow

HSPR4

HSPR4

HSPR4L

HSPR4L

1, 3R, 12, 4, 4X

IP65

Yes

Black

HSPB4T

HSPB4T

HSPB4LT

HSPB4LT

1, 3R, 12, 4, 4X

IP65

Yes

Red / Yellow

HSPR4T

HSPR4T

HSPR4LT

HSPR4LT

Function

Note: handle is defeatable, and is padlockable in the “OFF” position.

Select a shaft

Shaft Length (in/mm)

Catalog Numbers

7.9 / 200

SS200-5

SS200-5

SS200-10

SS200-10

12.6 / 320

SS320-5

SS320-5

SS320-10

SS320-10

15.7 / 400

SS400-5

SS400-5

SS400-10

SS400-10

19.7 / 500

-

-

SS500-10

SS500-10

NFPA 79 Front Operation Kit
NFPA 79 Front Operation Kit

HADB6

HADB6

NFPA791

NFPA791

Note: allows to operate & padlock the switch when door of enclosure is open. For full information on
NFPA79 requirements and on our solution, please consult P42 of this Advisor Catalog.

K

Catalog Numbers

Select a kit

Options for external front
and side operation
	
Catalog Numbers
Terminal Lugs Kit (for 2, 3 and 4 pole switches)

integral

integral

integral

integral

Terminal Shrouds (for 2, 3 and 4 pole switches)

integral

integral

integral

integral

Shorting Links Kit (3 links per Kit)

CCNL30

JNL30

JNL30

SL60

Direct Front Operation Handle

HADB1

HADB2

Auxiliary contact
Auxiliary contact block holder

ACHCD

ACHCD

-

-

1 N / O, 10A, 600VAC snap-on contact block, A600-Q600(1)

AC3

AC3

AC3

AC3

1 N / C, 10A, 600VAC snap-on contact block, A600-Q600(1)

AC4

AC4

AC4

AC4

1 NO + NC side mount contact block, A600-N600

-

AC5

AC5

AC5

-

AC6

AC6

AC6

(2)

2 NO + NC side mount contact blocks, A600-N600(2)

(1) C
 ompact Design Fusible Disconnect Switch accommodates up to 4 auxiliary contacts for FBCC30CDT and
FBCC30SNCDT and up to 2 auxiliary contacts for FBJ30CDT and FBJ30SNCDT on the switch.	
(2) Two auxiliary contact blocks maximum can be side mounted.			
Note : For class T fuse adaptors, please consult us.					
			

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K19

Fusible Disconnect Switches FB Series
Front and side operated range from 100 to 800A
Catalog Numbers
Ampere Rating
Select a switch

100

200

400

600

800

2-Pole

FBJ1002X

FBJ2002X

-

-

-

3-Pole

FBJ1003X

FBJ2003X

FBJ400U

FBJ600U

FBL800U

4-Pole

FBJ1004X

FBJ2004X

FBJ4004U

FBJ6004U

FBL8004U

J

J

J

J

L

Fuse class

S type pistol handle for external front and side operation

Select a handle

Test

Color

Catalog Numbers

NEMA Type

IEC

1, 3R, 12

IP54

No

Black

HSPBL

HSPBL

HSPBL

HSPBEL

HSPBEL

1, 3R, 12

IP54

No

Red / Yellow

HSPRL

HSPRL

HSPRL

HSPREL

HSPREL

1, 3R, 12, 4, 4X

IP65

No

Black

HSPB4L

HSPB4L

HSPB4L

HSPB4EL

HSPB4EL

1, 3R, 12, 4, 4X

IP65

No

Red / Yellow

HSPR4L

HSPR4L

HSPR4L

HSPR4EL

HSPR4EL

1, 3R, 12, 4, 4X

IP65

Yes

Black

HSPB4LT

HSPB4LT

HSPB4LT

†

HSTB4

HSTB4†

1, 3R, 12, 4, 4X

IP65

Yes

Red / Yellow

HSPR4LT

HSPR4LT

HSPR4LT

HSTR4†

HSTR4†

Function

Note: Handle is defeatable, and is padlockable in the “OFF” position.
Select a shaft

ss
Shaft Length (inches / mm)

†

T-bar type handle. No test function.

Catalog Numbers

7.9 / 200

SS200-10

SS200-10

SS200-10

SS200-12

SS200-12

12.6 / 320

SS320-10

SS320-10

SS320-10

SS320-12

SS320-12

15.7 / 400

SS400-10

SS400-10

SS400-10

SS400-12

SS400-12

19.7 / 500

SS500-10

SS500-10

SS500-10

SS500-12

SS500-12

NFPA 79 Front Operation Kit
Catalog Numbers

Select a kit

NFPA 79 Front Operation Kit

NFPA791

NFPA791

NFPA791

NFPA792

NFPA792

Note: allows to operate & padlock the switch when door of enclosure is open. For full information on NFPA79 requirements
and on our solution, please consult P42 of this Advisor Catalog.

Options for external front and side operation
Catalog Numbers
Pistol Handle for Direct Front Operation

-

-

-

HADBSU

HADBSU

4 lugs per kit - for 2 pole switches

Intergral

TL200X4

-

-

-

6 lugs per kit - for 3 pole switches

Intergral

TL200X6

TL400

TL600

TL600

8 lugs per kit - for 4 pole switches

Intergral

TL200X8

TL4004

TL6004

TL6004

2-pole (for line or load side)

Intergral

TS2002FBX

-

-

-

3-pole (for line or load side

Intergral

TS2003FBX

TS400FB(2)

TS800U

TS800U

4-pole (for line or load side)

Intergral

TS2004FBX

TS4004FB(2)

TS8004U

TS8004U

Shorting links kit (3 links per kit)

SL100

SL200

SL400

SL800

SL800

1 N/O, 10A, 600 VAC snap-on-contact block, A600-Q600

AC3

AC3

AC3

AC3

AC3

1 N/C, 10A, 600 VAC snap-on-contact block, A600-Q600

AC4

AC4

AC4

AC4

AC4

1 NO+NC side mount contact block, A600-N600(3)

AC5

AC5

AC5

AC5

AC5

2 NO+NC side mount contact blocks, A600-N600(3)

AC6

AC6

AC6

AC6

AC6

Terminal Lugs Kit

Terminal shrouds kit(1)

Auxiliary contacts

(1) Line side shrouding supplied as standard with switch.
(2) As a replacement part for line or load side (two terminal screens supplied as standard with switch).
(3) Two auxiliary contact blocks maximum can be side mounted.
Note: for class T fuse adaptors, please consult Mersen.

K20

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fusible Disconnect Switches FB Series
Flange Operated Range from 30 to 400A
Catalog Numbers
Select a switch

Ampere Rating

30

60

100

200

400

2-Pole

FBJ302X

FBJ602X

FBJ1002X

FBJ2002X

-

3-Pole

FBJ3003X

FBJ603X

FBJ1003X

FBJ2003X

FBJ400U

4-Pole

FBJ3004X

FBJ604X

FBJ1004X

FBJ2004X

FBJ4004U

Fuse class

J

J

J

J

J

Cable flange operated handle (square D type - class 9422)
Select a handle

NEMA Type

IEC

1, 3R, 12, 4, 4X

IP54

HAF-OP1(1)

HAF-OP1(1)

Catalog Numbers
HAF-OP1(1)

HAF-OP1(1)

HAF-OP1(1)

4, 4X

IP65

HAF-OP2(2)

HAF-OP2(2)

HAF-OP2(2)

HAF-OP2(2)

HAF-OP2(2)

Note: Handle is defeatable, and padlockable in the “OFF” position.
Mechanism

Mechanism

HAF-MECHX

HAF-MECHX

HAF-MECHX

HAF-MECHX

HAF-MECHX

HAFC36

HAFC36

HAFC36

HAFC36

HAFC36

60 / 1,524

HAFC60

HAFC60

HAFC60

HAFC60

HAFC60

120 / 3,048

HAFC120

HAFC120

HAFC120

HAFC120

HAFC12

Cable Length (inches / mm)
36 / 914.4
Select a cable

Note: Cable flange operation is for enclosure depth from 5.75”/145mm to 36”/990mm, depending on the cable length.

Rod flange operated handle (square D type - class 9422)
Select a handle

NEMA Type

IEC

1, 3, 3R, 4, 12

IP54

HAF-OP1(1)

HAF-OP1(1)

Catalog Numbers
HAF-OP1(1)

HAF-OP1(1)

HAF-OP1(1)

4, 4X

IP65

HAF-OP2(2)

HAF-OP2(2)

HAF-OP2(2)

HAF-OP2(2)

HAF-OP2(2)

HAFRX

HAFRX

HAFRX

HAFRX

Note: handle is defeatable, and padlockable in the “OFF” position.
Rod Length (inches / mm)	
Select a rod

23.6 / 500

HAFRX

K

Note: Rod kit is for enclosure depth from 8 / 203 to 24.12 / 613 For smaller depth, please consult us.

Pistol handle for direct side operation (not NFPA 79)
Color
Select a handle

Catalog Numbers

Black

HADB4

HADB4

HADB4

HADB4

HADB4

Note: Handle is padlockable in the “OFF” position.

Options for flange & direct operation handle from 30 to 400 A
Terminal lugs kit

Catalog Numbers

6 lugs per kit - for 2 pole fuse switches

Intergral

Intergral

Intergral

TL200X4

TL400

6 lugs per kit - for 3 pole fuse switches

Intergral

Intergral

Intergral

TL200X6

TL400

8 lugs per kit - for 4 pole fuse switches

Intergral

Intergral

Intergral

TL200X8

TL4004

Terminal shrouds kit(4)
2-pole (for line or load side)

Intergral

Intergral

Intergral

TS2002FBX

-

3-pole (for line or load side)

Intergral

Intergral

Intergral

TS2003FBX

TS400FB(5)

4-pole terminal shrouds kit(4) (for line or load side)

Intergral

Intergral

Intergral

TS2004FBX

TS4004FB(5)

Shorting links kit (3 links per kit - for 3 pole fuse switches)

JNL30

SL60

SL100

SL200

SL400

Auxiliary contacts

(3)

1 NO+NC side mount contact block, A600 - N600

AC5

AC5

AC5

AC5

AC5

2 NO+NC side mount contact blocks, A600 - N600

AC6

AC6

AC6

AC6

AC6

(1) All external metal parts are sheet steel. (2) All external metal parts are either stainless steel or a chrome-plated non-ferrous die casting.
(3) Two auxiliary contact blocks maximum can be side mounted. (4) Line side Shrouding supplied as standard with switch.
(5) As a replacement part (two terminal screens supplied as standard with switch). Note: for class T fuse adaptors, please consult us.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K21

Fusible Disconnect Switches FB Series
Technical Characteristics for Front and Side Operation
Catalog Numbers - UL, cUL and CSA
Catalog Numbers

FBCC30CDT / FBCC30SNCDT

FBJ30CDT / FBJ30SNCDT

FBJ302X / FBJ303X / FBJ304X

Ampere Rating (A)

30

30

30

Fuse type

CC

J

J

Operating voltage (V)

600

600

600

Max Horsepower Rating / Max Motor FLA Current Three-Phase
208 V

5 / 17.5

5 / 17.5

5 / 17.5

240 V

7.5 / 22

7.5 / 22

7.5 / 22

480 V

15 / 21

15 / 21

15 / 21

600 V

20 / 22

20 / 22

20 / 22

DC 125 V - 2-pole in series

3 / 25

3 / 25

3 / 25

DC 250 V - 3-pole in series

5 / 20

5 / 20

5 / 20

Max Horsepower Rating / Max Motor FLA Current Single-Phase
240 V AC

-

-

3 / 17

480 V AC

-

-

7.5 / 21

Short circuit rating with fuses (SCCR) (kA)

100

100

200

Branch circuit fuse type

CC

J

J

Max fuse rating (A)

30

30

30

H (in)

4.56

4.56

5.35

W (in)

3.78

4.13

5.88

D (in)

3.28

3.89

4.84

in

0.2 x 0.2

0.2 x 0.2

0.4 x 0.4

mm

5x5

5x5

10 x 10

3-pole switch operating torque (front operation) (lb in)

21

21

88

Terminal lugs kit (# of lugs per kit)

Integral

Integral

Integral

Wire range AWG (# of wire holes per lug)

#10-#14 (1)

#10-#14 (1)

#6-#10 (1)

Wire tightening torque

27

27

58

Short Circuit Rating

Dimension 3-pole

Shaft size square

K22

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fusible Disconnect Switches FB Series
Technical Characteristics for Front and Side Operation
Catalog Numbers - UL, cUL and CSA
Catalog Numbers

FBJ602X
FBJ603X
FBJ604X

FBJ1002X
FBJ1003X
FBJ1004X

FBJ2002X
FBJ2003X
FBJ2004X

FBJ400U
FBJ4004U

FBJ600U
FBJ6004U

FBL800U
FBL8004U

Ampere Rating (A)

60

100

200

400

600

800

Fuse type

J

J

J

J

J

L

Operating voltage (V)

600

600

600

600

600

600

Max Horsepower Rating / Max Motor FLA Current Three-Phase
208 V

15 / 48.5

25 / 78.5

50 / 150

100 / 286

-

-

240 V

15 / 42

30 / 80

60 / 154

125 / 312

200 / 480

200 / 480

480 V

30 / 40

60 / 77

125 / 156

250 / 302

400 / 477

500 / 590

600 V

50 / 52

75 / 77

150 / 144

350 / 336

500 / 472

500 / 472

DC 125 V - 2-pole in series

3 / 25

7.5 / 58

-

20 / 148

-

-

DC 250 V - 3-pole in series

10 / 38

20 / 38

-

50 / 173

-

-

Max Horsepower Rating / Max Motor FLA Current Single-Phase
240 V AC

10 / 50

10 / 50

-

-

-

-

480 V AC

10 / 26

10 / 26

-

-

-

-

Short circuit rating with fuses (SCCR) (kA)

100

200

200

200

200

200

Branch circuit fuse type

J

J

J

J

J

L

Max fuse rating (A)

60

100

200

400

600

800

H (in)

5.35

7.32

7.72

14.31

11.86

11.86

W (in)

5.88

5.88

7.68

11.93

14.31

14.31

D (in)

4.84

4.84

5.12

5.56

11.42

11.42

in

0.4 x 0.4

0.4 x 0.4

0.4 x 0.4

0.4 x 0.4

4.7 x 4.7

4.7 x 4.7

mm

10 x 10

10 x 10

10 x 10

10 x 10

12 x 12

12 x 12

3-pole switch operating torque (front operation) (lb-in)

88

88

106

132

350

350

Terminal lugs kit (# lugs per kit)

Integral

Integral

Optional (6)

Optional (6)

Optional (6)

Optional (6)

Wire range AWG (# of wire holes per lug)

#6-#10 (1)

#1-#12 (1)

300kcmil - #6 (1)

600kcmil-#2 (1)

600kcmil-#2 (2)

600kcmil-#2 (2)

Wire tightening torque (lb-in)

120

200

275 max

375

375

375

Short Circuit Rating

Dimension 3 pole (front operated switches)

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K

Shaft size square (front operated switches)

K23

Fusible Disconnect Switches FB Series
Dimensions (in/mm) for Front and Side Operation
Fusible Disconnect Switch CD 30 A CC
FBCC30CDT

C

FBCC30SNCDT

A

Y

J

J1
Y

X
B

K1

K

Ø 0.20
Ø 5.2

H1

Fusible Disconnect Switch CD 30 A J
FBJ30CDT

A

C

FBJ30SNCDT

J1

J

Y

Y

X
B

K

Ø 0.20
Ø 5.2

B

C

H1

H3

J

J1

K

K1

Y

Number

Rating

of Poles

In

mm In

mm In

mm In

mm In

mm In

mm In

mm In

mm In

mm In

mm

3P

3.78

96

4.56

116

3.28

83.5

5.19

132

-

-

1.47

37.5

0.59

15

3.3

84

1

25.5

1.12

28.5

3P

4.13

105

4.56

116

3.89

99

-

-

-

-

1.47

37.5

0.59

15

3.30

84

1

25.5

1.12

28.5

30 A CC
CD type
30 A J
CD type

K24

A

Ampere

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K1

Fusible Disconnect Switches FB Series
Dimensions (in/mm)
Fusible Disconnect Switch 30A and 60A
FBJ303X*

5.87
149.3
1.41
36

1.46
37.2

4.84
123

1.41
36

4.02
102.1

5.35
136

FBJ603X*

Fusible Disconnect Switch 100A
5.87
149.3
1.41
36

1.46
37.2

4.81
122.2

1.41
36

K

5.23
133

6.77
172

7.32
186

FBJ103X*

*Note: For 4-pole or 2-Pole versions, add or subtract 1.41” / 36mm.

Fusible Disconnect Switch 200A
FBJ203X**

7.72
196.2
6.61
168

11.46
291.3

7.67
195

6.50
165.2

5.28
134.2

6.18
157

1.41
36
5.11
130

1.96
50

**Note: For 4-pole or 2-Pole versions, add or subtract 1.96” / 50mm.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K25

Fusible Disconnect Switches FB Series
Dimensions (in/mm) for Front and Side Operation
Fusible Disconnect Switch 400A
FBJ400U

0.40 1.14
10.3 29

C

FBJ4004U

J

J1
M10

K1

6.53
166

X

5
126.5

B

H

Y

Ø 0.26
Ø 6.5

H2

K

H3 H2

Y

J
A

H1

Fusible Disconnect Switch 600A - 800A
FBJ600U / FBJ6004U

2
51

.78
20

C

FBL800U / FBL8004U

.Ø

.51
13

H1

J
2.32
59

.27
7

H3

1.81
46

1.34
34

.43
11

.27
7
3.54
90

11.81 10.23 9.84 5
300 260 250 126.5

.27
8.26
7
210 H

.40
10.3

8.42
214

Y
X

10.15
258
.35
9
J1

J1
A

C1
	
B

No of

Rating

Poles

In

mm In

3P

10.8

276

4P

13.7

348

3P
4P

400 A
600 A,
800 A

K26

A

Ampere

C

mm In

C1

H

H1

mm In

mm In

mm In

14.31 363.5 5.56

141.5 -

-

5.28

134.5 11.41 290

14.31 363.5 5.56

141.5 -

-

5.28

134.5 11.41 290

14.33 364

-

-

9.84

250

14.72 374

11.69 297

6.10

18.03 458

-

-

9.84

250

14.72 374

11.69 297

6.10

H2

mm In

H3

J

J1

K

K1

Y

mm In

mm In

mm In

mm In

mm In

mm In

mm

7.04

179

6.59

167.5 2.84

72

0.88

22.5

8.83

224

4.41

112

1.06

27

7.04

179

6.59

167.5 2.84

72

0.88

22.5

8.83

224

4.41

112

1.06

27

155

-

-

2.56

65

11.18 284

3.70

94

-

-

-

-

-

-

155

-

-

2.56

65

14.88 378

3.70

94

-

-

-

-

-

-

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fusible Disconnect Switches FB Series
Dimensions (in/mm) for External Front Operation Handles
S type pistol handle
HSPB

Front operation

HSPR
HSPB4
HSPR4

HSPBL
HSPRL
HSPB4L
HSPR4L

HSPBEL
HSPREL

Side operation

HSPB4EL

K

HSPR4EL

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K27

Fusible Disconnect Switches FB Series
Dimensions (in/mm) from Backplate to Door Distance with Shaft Extension
Minimum distance (in / mm)

h

H & C Minimum Dimension

All HSP Handles
In

mm

Fusible Disconnect Switch CD 30 A CC

5.31

135

Fusible Disconnect Switch CD 30 A J

5.98

152

Fusible Disconnect Switch 30 A J - 60 A J

6

153

Fusible Disconnect Switch 100 A J

6

153

Fusible Disconnect Switch 200 A J

8

203.5

Fusible Disconnect Switch 400 A J

12

305

Fusible Disconnect Switch 600 A J - 800 A L

12

305

S type pistol handle
FBJ400U

FBJ600U	

FBJ6004U

FBCC30CDT	

FBCC30SNCDT

FBJ4004U

FBL800U	

FBL8004U

FBJ30CDT	

FBJ30SNCDT

L
L = X - 1.71
L = X - 43.5

min. 0.78 in / 20 mm
max. 1.18 in / 30 mm

X

C
min. 1.5 in
m
. 40 mm

L
L X
L X

door

C

4.04
104

min.

0.90
23
(only for
S type)
X

K28

0.76
19.5

L
L = X-1.45
L = X-37

1.02
26±4

0.39
10

X
X min. 10.43 in / 265 mm

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fusible Disconnect Switches FB Series
Dimensions (in / mm) for Direct Front Operation Handles
Direct pistol handle
HADB1

HADB2
4.41
112

5.11
130

HADB5U

7.48
190

2.36
60

3.35
85

Dimensions (in / mm) for Flange Operation Handles
Square D type flange handle - class 9422 (A1 & A2)
HAF-OP1

K

HAF-OP2

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K29

Fusible Disconnect Switches FB Series
Dimensions (in / mm) for Terminal Lugs
TL200X
For use with FBJ 200xX

1 wire 300kcmil - #6

TL400

TL600

For use with FBJ400

For use with FBJ600U and FBL800U

Ø 0.406 THRU
Ø 10.3 THRU

Ø 13 / 16
Ø 20.6

1.5
38.1
0.750 / 19
0.590
15
1.623
41.2

1.375
35
1.125
28.6

Ø 0.938 x 1.40
Ø 23.8 x 35.6

1.875
47.6

0.750 / 19
0.125
3.2

0.687 / 17.45

1.094
27.8

0.827
21

1 wire 600 MCM-2

2 wire 600 MCM-2

Note: for FBJ400, please use HM bolts 10 x 30 mm class 6.8.

K30

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Enclosed Disconnect Switches
Mersen enclosed disconnect switches are designed to meet customer’s requirements
for compact and durable individual disconnecting means. Both fusible and non-fusible
versions are available in a variety of enclosures types resulting in one of the largest
available ranges in the industry. The enclosed disconnect switch range offers safety,
ease of installation, space savings and operational convenience to end-users.
Mersen features NEMA style, Type 4X non-metallic and stainless steel enclosures
that are extremely durable and provide the ultimate protection for harsh environments
and conditions. These rugged enclosure types are often used in areas where “wash
down” applications are required.

Highlights:

Applications:

•• Suitable for use as motor

•• Load break switching

disconnect

•• Separate disconnect means within

•• Meets OSHA lockout/tagout
requirements

sight of all motor loads to comply

Ratings:

with NEC® Article 430

Fusible

•• NEMA rated enclosures

•• Circuit isolation

•• Knockouts provided

Volts	

•• Service entrance ratings available

•• Easy screw mounting

Amps	 : 30 to 800A

•• Food processing

•• Selector or pistol handles in black

Non-Fusible

•• Conveyor systems

Volts	

•• Harsh industrial environments

Amps	 : 16 to 1200A

or red/yellow
•• Clear ON/OFF indication

Volts	

: 600VAC

: 600VAC

: 600VDC

K

Amps	 : 100 to 400A

Approvals:
•• UL 508A
•• UL 508
•• UL 98
•• CSA
•• IEC versions available

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K31

Enclosed Disconnect Switches
Part Numbering Guideline (example)
ED

FS

30

3

Enclosure Type

Switch Type

Amp Rating

Number of Poles

R

S

0

Color of handle:

Type of handle:

R = Red/yellow

S = Selector

B = Black

P = Pistol

-

Auxiliary contacts:
See chart below

Other options

Pre-break, Pre-mounted Auxiliary Contacts
Catalog Suffix

Switch Style

0

1

2

3

Non-fusible, UL508

FSLBS 16-80A

None

-

-

1 NO + NC

Non-fusible, UL98

Fusible Disconnect Switch 30-1200A

None

1 NO

1 NC

1 NO + NC

Fusible, UL98

Fusible Disconnect Switch 30 – 800A

None

1 NO

1 NC

1 NO + NC

Other Options
Please consult factory for availability and suffix for any other options including:
•• Neutral blocks (N)
•• Terminal Shrouds are integral or standard with many of our switches. If terminal shrouds are necessary, add a “T” to the
end of the part number.
•• Special Request
	

- Pilot Lights

	

- Pushbuttons

	

- 2 or 3 position selector switches

All enclosed switches are provided with a standard integral ground lug
Box type

Switch type

Ground lug wire size

NEMA/UL

16 – 60A

(2) #4 – #14

NEMA/UL

80 – 125A

(2) 1/0 – #14

NEMA/UL

200 – 400A

(2) 600kcmil – #2

NEMA/UL

600A & above

Consult Factory

Note: EDFS 40A, 60A & 80A use grounding stud

Enclosure Application Information

K32

Enclosure Type

Intended Use and Description

NEMA

1

Indoor use primarily to provide a degree of protection against contact with the enclosed equipment and against a limited amount of falling dirt.

NEMA

3R

Intended for outdoor use primarily to provide a degree of protection against rain, sleet, and damage from external ice formation.

NEMA

12

Intended for indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping non-corrosive liquids.

NEMA

4

NEMA

4X

IEC

IP65

Intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, hose-directed water, and damage
from external ice formation.
Intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, wind blown dust and rain, splashing water, hose-directed water,
and damage from ice formation.
Total protection against dust and protected against water jets from any hosed direction.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Enclosed Disconnect Switches
NEMA ENCLOSURE

1

3 Pole, 600V 30-1200A, Non-fused

3R

12

Ampere Rating (A)

UL 98

4X

4X

Stainless

Non-Metallic

Catalog Numbers

30

Special compact polycarbonate enclosures

60

Special compact polycarbonate enclosures

EJFS303RS0
EJFS603RS0

16

EAFS163RS0

EFFS163RS0

ECFS163RS0

EHFS163RS0

EBFS163RS0

EDFS163RS0

20

EAFS203RS0

EFFS203RS0

ECFS203RS0

EHFS203RS0

EBFS203RS0

EDFS203RS0

25

EAFS253RS0

EFFS253RS0

ECFS253RS0

EHFS253RS0

EBFS253RS0

EDFS253RS0

30

EAFS303RS0

EFFS303RS0

ECFS303RS0

EHFS303RS0

EBFS303RS0

EDFS303RS0

40

EAFS403RS0

EFFS403RS0

ECFS403RS0

EHFS403RS0

EBFS403RS0

EDFS403RS0

60

EAFS603RP0

EFFS603RP0

ECFS603RP0

EHFS603RP0

EBFS603RP0

EDFS603RP0

80

EAFS803RP0

EFFS803RP0

ECFS803RP0

EHFS803RP0

EBFS803RP0

EGFS803RP0

30

EAFC303RP0

EFFC303RP0

ECFC303RP0

EHFC303RP0

EBFC303RP0

EGFC303RP0

60

EAFC603RP0

EFFC603RP0

ECFC603RP0

EHFC603RP0

EBFC603RP0

EGFC603RP0

100

EAFC1003RP0

EFFC1003RP0

ECFC1003RP0

EHFC1003RP0

EBFC1003RP0

EGFC1003RP0

200

EAFC2003RP0

EFFC2003RP0

ECFC2003RP0

EHFC2003RP0

EBFC2003RP0

EGFC2003RP0

400

EAFC4003RP0

EFFC4003RP0

ECFC4003RP0

EHFC4003RP0

EBFC4003RP0

EGFC4003RP0

600

EASC6003RP0

EFSC6003RP0

ECSC6003RP0

EHSC6003RP0

EBSC6003RP0

EGSC6003RP0

800

EASC8003RP0

EFSC8003RP0

ECSC8003RP0

EHSC8003RP0

EBSC8003RP0

EGSC8003RP0

1000

EASC10003RP0

EFSC10003RP0

ECSC10003RP0

EHSC10003RP0

EBSC10003RP0

EGSC10003RP0

1200

EASC12003RP0

EFSC12003RP0

ECSC12003RP0

EHSC12003RP0

EBSC12003RP0

EGSC12003RP0

NEMA ENCLOSURE

1

3R

12

4

4X Stainless

3 Pole, 600V 30-800A, Fused
Ampere Rating (A)

UL 98

4X
Non-Metallic

Fuse

Catalog Numbers

Type

30, compact

CC

EAFBCC303RP0

EFFBCC303RP0

ECFBCC303RP0

EHFBCC303RP0

EBFBCC303RP0

EGFBCC303RP0

30, compact

J

EAFBJC303RP0

EFFBJC303RP0

ECFBJC303RP0

EHFBJC303RP0

EBFBJC303RP0

EGFBJC303RP0

30

J

EAFBX303RP0

EFFBX303RP0

ECFBX303RP0

EHFBX303RP0

EBFBX303RP0

EGFBX303RP0

60

J

EAFBX603RP0

EFFBX603RP0

ECFBX603RP0

EHFBX603RP0

EBFBX603RP0

EGFBX603RP0

100

J

EAFBX1003RP0

EFFBX1003RP0

ECFBX1003RP0

EHFBX1003RP0

EBFBX1003RP0

EGFBX1003RP0

200

J

EAFBX2003RP0

EFFBX2003RP0

ECFBX2003RP0

EHFBX2003RP0

EBFBX2003RP0

EGFBX2003RP0

400

J

EAFBJ4003RP0

EFFBJ4003RP0

ECFBJ4003RP0

EHFBJ4003RP0

EBFBJ4003RP0

EGFBJ4003RP0

600

J

EAFBJ6003RP0

EFFBJ6003RP0

ECFBJ6003RP0

EHFBJ6003RP0

EBFBJ6003RP0

EGFBJ6003RP0

800

L

EAFBL8003RP0

EFFBL8003RP0

ECFBL8003RP0

EHFBL8003RP0

EBFBL8003RP0

EGFBL8003RP0

K

UL 508

4

Notes:	Each of the above enclosed switches are listed having a red/yellow handle. Simply replace the “RS” or “RP” with a “BS” or “BP” to receive with a black
selector or black pistol handle. The non-metallic enclosures are comprised of “ED” polycarbonate and “EG” polyester fiberglass.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K33

Enclosed Disconnect Switches
Switch

Enclosure

H

W

D

MH mounting

MW mounting

Shipping

Figure

Rating

Type

height (in)

width (in)

depth (in)

height (in)

width (in)

Weight (lbs)

No.

1

8

8

6

5

7

10

2

16–40A
(FSLBS)
UL508

60A
(FSLBS)
UL508

80A
(FSLBS)
UL508

100A
(FSSC)
UL98

3R

8

8

6

9

3

11

1

12

8

6

6

8.75

4

7

1

4

5.91

5.91

4.72

5.2

3.35

7

2

4X Stainless

5.91

5.91

4.72

5.2

3.35

7

2

4X Non-Metallic

7

5

5

6.18

4.21

2

2

1

8

8

6

5

7

10

2

3R

8

8

6

9

3

10

1

12

8

6

6

8.75

4

7

1

4

7.87

5.91

4.72

7.17

3.35

7

2

4X Stainless

7.87

5.91

4.72

7.17

3.35

7

2

4X Non-Metallic

7

5

5

6.18

4.21

4

2

1

10

8

6

7

7

10.6

2

3R

10

8

6

11

3

11.1

1

12

10

8

6

10.75

6

12.3

1

4

9.84

7.87

5.91

9.13

5.31

9.8

2

4X Stainless

9.84

7.87

5.91

9.13

5.31

9.8

2

4X Non-Metallic

11.3

9.31

5.43

10.75

6

6

1

1

10

8

6

7

7

10.6

2

3R

10

8

6

11

3

11.1

1

12

10

8

6

10.75

6

12.3

1

4

10

8

6

10.75

6

11.8

1

4X Stainless

9.84

7.87

5.91

9.13

5.31

9.8

2

4X Non-Metallic

11.31

9.31

5.43

10.75

6.02

7.6

1

Dimensions (in / mm)

K34

Figure 1

Figure 3

Figure 2

Figure 4

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Switch
Rating

125A
(LBSR)
UL508

30A
(FSSC)
UL98

60A
(FSSC)
UL98

100A
(SX)
UL98

200A
(SX)
UL98

Enclosure
Type

H
height (in)

W
width (in)

D
depth (in)

MH mounting
height (in)

MW mounting
width (in)

Shipping
Weight (lbs)

Figure
No.

1

10

8

6

7

7

10.6

2

3R

10

8

6

11

3

11.1

1

12

10

8

6

10.75

6

12.4

1

4

10

8

6

10.75

6

11.9

1

4X Stainless

9.84

7.87

5.91

9.13

5.31

9.8

2

4X Non-Metallic

11.31

9.31

5.43

10.75

6.02

7.6

1

1

8

8

6

5

5

9.3

2

3R

8

8

6

9

3

10.2

1

12

7.87

5.91

4.72

5.2

3.35

7.6

1

4

7.87

5.91

4.72

5.2

3.35

7.6

1

4X Stainless

9.844

7.87

5.91

9.13

5.31

10.1

2

4X Non-Metallic

9.3

7.31

4.96

8.74

4.01

6.2

1

1

12

12

6

9

11

16

2

3R

12

10

6

13

3

17.6

1

12

12

12

6

12.75

10

21.6

1

4

12

12

6

12.75

10

21.9

1

4X Stainless

11.81

9.84

5.91

11.1

7.28

17.4

2

4X Non-Metallic

13.3

11.29

7.1

12.75

8.01

12.9

1

1

12

12

6

9

11

16

2

3R

12

10

6

13

3

17.6

1

12

12

12

6

12.75

10

21.6

1

4

12

12

6

12.75

10

21.9

1

4X Stainless

12

10

6

12.75

8

18.6

1

4X Non-Metallic

13.3

11.29

7.1

12.75

8.01

12.9

1

1

30

20

8.62

27.5

15

68.6

2

3R

30

14

8

31

13

88.6

1

12

30

20

8

28.5

18.5

70.1

2

4

30

20

8

28.5

18.5

70.1

2

4X Stainless

30

20

10

28.5

18.5

71

1

4X Non-Metallic

32.87

25

11.81

34.72

22.91

59.3

1

K

Enclosed Disconnect Switches

Note: Dimensions are subject to change! Please consult factory for verification.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K35

Enclosed Disconnect Switches
Switch

Enclosure

H

W

D

MH mounting

MW mounting

Shipping Weight

Rating

Type

height (in)

width (in)

depth (in)

height (in)

width (in)

(lbs)

No.

1

8

8

6

5

7

9.4

2

30A
(FBCC
Compact)
UL489

30A
(FBJ
Compact)
UL489

30A
(FBX)
UL98

60A
(FBX)
UL98

100A
(FBX)
UL98

200A
(FBX)
UL98

3R

8

8

6

9

3

10.3

1

12

9.84

7.87

5.91

9.13

5.31

10.8

1

4

9.84

7.87

5.91

9.13

5.31

10.8

1

4X Stainless

9.84

7.87

5.91

9.13

5.31

11.3

2

4X Non-Metallic

11.31

9.31

6.93

10.75

6.02

9.7

1

1

12

12

8

9

11

18.3

2

3R

12

12

10

13

3

23.2

1

12

12

10

8

12.75

8

14.4

1

4

13.78

11.81

7.87

13.07

9.25

22.4

2

4X Stainless

13.78

11.81

7.87

13.07

9.25

24.3

2

4X Non-Metallic

11.31

9.31

6.93

10.75

6.02

9.7

1

1

12

12

8

9

11

18.3

2

3R

12

12

10

13

5

23.2

1

12

12

10

8

12.75

8

21.9

1

4

13.78

11.81

7.87

13.07

9.25

22.4

2

4X Stainless

13.78

11.81

7.87

13.07

9.25

24.3

2

4X Non-Metallic

15.32

13.3

8.19

14.75

10

17.1

1

1

12

12

8

9

11

18.2

2

3R

12

12

10

13

5

23.1

1

12

12

10

8

12.75

8

14.6

1

4

13.78

11.81

7.87

13.07

9.25

24.2

2

4X Stainless

13.78

11.81

7.87

13.07

9.25

24.2

2

4X Non-Metallic

15.32

13.3

8.19

14.75

10

17.5

1

1

20

16

8.62

17.88

11

35.2

2

3R

18

18

10

19

13

41.3

1

12

20

16

8

21.24

10

35.2

1

4

20

16

8

18.5

14.5

39

2

4X Stainless

20

16

8

18.5

14.5

38.1

2

4X Non-Metallic

19.31

17.31

9.58

18.74

12

25.6

1

1

24

20

8.62

21.96

12.76

56.6

2

3R

24

24

10

25

13

61.2

1

12

24

20

8

25.24

14

51

1

4

24

20

8

22.5

18.5

49.5

2

4X Stainless

24

20

8

22.5

18.5

50.5

2

4X Non-Metallic

28.94

21

10.63

30.79

18.97

46.3

1

Note: Dimensions are subject to change! Please consult factory for verification.

K36

Figure

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fusible Shunt Trip
Mersen’s engineered switches offer modular industrial control panels featuring a
fusible shunt trip to allow for remote disconnection. An array of available options
allows for maximum functionality to be built into a single compact panel.
Panels built for elevator applications feature control transformers (fusing both
primary and secondary sides), a fire safety interface relay with a fire alarm voltage
monitoring relay and mechanically interlocked auxiliary contacts. Use of Mersen’s
Amp-Trap 2000® AJT Class J fuses permits easy selectivity coordination, while
providing the panel and its components with superior current limitation and the
ability to withstand high fault conditions. AJT fuses provide added system reliability
since no maintenance or periodic testing is required as with other electromechanical
overcurrent devices.

Features/Benefits:
•• Fused switch – provides high current limitation and short circuit withstand
•• Padlockable handle – allows panel to be locked with switch in the off
position ensuring load side power isolation during servicing
•• Shunt trip – allows for remote tripping of the main line power prior to the
application of water in elevator

Volts	

: 600VAC

Amps	 : 30A, 60A, 100A, 200A 	
& 400A

	

•• Sprinkler system applications

Highlights:

Applications:

•• 3-Pole fused switch

•• Elevators

•• 120 VAC Shunt Trip

•• Building emergency systems

•• Class J fuse block (fuses not

•• Data processing rooms

included)

Ratings:

•• Miscellaneous fusible shunt trip

•• Ground lug as per NEC

applications

K

•• Control power brought to terminals
•• Modular components
•• NEMA 1 Industrial enclosure
standard

Approvals:
•• UL 1087 molded-case switch

Optional Features:

•• UL 50
•• NEMA 1, 12, 3R, 4, 4X

•• Industrial control circuit transformer

•• UL 512

•• Primary (208, 240, 480 or 600 VAC)

•• UL / cUL listed control panel

•• Fire safety relay for control interface (3PDT Relay, choice of Coil Voltage:
•• Oil-tight key switch to test 2 position selector switch.

Recommended Fuse
Usage:

•• Oil-tight power enabled power light (choice of colors: red, green, white or

•• ES Series - Use with AJT, A4J,

120 VAC, 24 VDC or 24VAC)

yellow)

HSJ

•• Isolated neutral lug – 100%. Oversized 200% for excessive Non-Linear
loads.
•• Auxiliary and alarm contacts are both Form C contacts. The auxiliary
contacts change state when the switch is in the on position. Alarm contacts
change state when the switch is in the tripped position. The alarm contact
is located in place of the second auxiliary contact.
•• NEMA 12, 3R, 4 or 4X enclosure available.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K37

Fusible Shunt Trip
An example of an Engineered Switch Catalog number is listed below with the ordering process detail.

ES2T20R1KRN2A2

Fusible Shunt Trip Switch Maximum Horsepower Ratings based on Motor Load

Select fusible shunt trip switch:

Ampere Rating (A)

30

60

100

200

400

Catalog

FLA %

Rating (A)

Number

208 VAC 3 (I)

5

5

3

10

10

10

20

15

15

40

40

30

75

75

60

30

ES3

240 VAC 3 (I)

5

5

5

10

10

10

20

20

15

50

40

30

125

75

75

60

ES6

100

ES1

200

ES2

400

ES4

VOLTAGE

Ampere

150 175 225 150 175 225 150 175 225 150 175 225 150 175 225

480 VAC 3 (I)

10

10

10

30

25

20

50

40

30

100

75

75

250

150

150

600 VAC 2 (I)

15

15

10

30

30

25

60

50

40

125

100

100

250

200

200

150...Light duty maximum allowable motor horsepower
based on Class J fuses

Select options:
Option No.

175...General duty maximum allowable motor horsepower

Description

based on Class J fuses

Catalog No.

Control Transformer
1 (Req’d)

208VAC to 120VAC

T20

240VAC to 120VAC

T24

480VAC to 120VAC

T48

600VAC to 120VAC

T60

225...Heavy duty maximum allowable motor horsepower
based on Class J fuses
Horsepower values in the above table are intended for estimating
the size of the switch only. For light duty applications size switch
for a minimum of 1.5 times the motor’s full load amps. Medium

Fire Safety Relay 3PDT with
2 (Req’d)

3

or general duty applications size for a minimum of 1.75 times the

Voltage Monitoring
120VAC coil

R1

full load amps of the motor. For heavy duty applications use a

24VDC coil

R2

maximum of 2.25 times the full load amps of the motor.

24VAC coil

R3

Keyswitch
Key to test switch, 120V, with legend plate

D

K

W

Pilot light - power enabled
4

Red

R

Green

G

White

W

Isolated Neutral Lug
5

30-60A

N1

100A (for 200% oversize use N2)

N1

200A (for 200% oversize use N4)

N2

400A (for 200% oversize use two N4)

N4

H

Mechanical Interlocked Auxiliary
Contacts
6 (Req’d)

1 Form C auxiliary contact

A

2 Form C auxiliary contacts

B

1 Form C auxiliary contact and 1 Form C
auxiliary alarm contact
Same as C plus handle-activated
microswitch

C
D

Enclosure Options

7

Fusible Shunt Trip Switch Dimensions and Optional Neutral Lug Sizes
Ampere
Rating (A)
Voltage

30
HxWxD

60
HxWxD

100
HxWxD

200
HxWxD

HxWxD

208 VAC 3 (I)

24 x 20 x 8

24 x 20 x 8

24 x 20 x 8

30 x 24 x 8

36 x 30 x 8

240 VAC 3 (I)

24 x 20 x 8

24 x 20 x 8

24 x 20 x 8

30 x 24 x 8

36 x 30 x 8

NEMA 1 standard

-

480 VAC 3 (I)

24 x 20 x 8

24 x 20 x 8

24 x 20 x 8

30 x 24 x 8

36 x 30 x 8

NEMA 12

2

600 VAC 3 (I)

24 x 20 x 8

24 x 20 x 8

24 x 20 x 8

30 x 24 x 8

36 x 30 x 8

NEMA 3R

3

Neutral Lug Size 350 - #6

350 - #6

350 - #6

500 - #4

600 - #2

NEMA 4

4

NEMA 4X

X

Note: Options must be selected in above order for part number to be valid.

K38

400

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fusible Shunt Trip
Fusible Shunt Trip Switch 120 VAC Fire Safety Control Interface

K

Fusible Shunt Trip Switch 24 VDC Fire Safety Control Interface

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

K39

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

High Power Switches
Expertly engineered for reliable performance

Your problem:

L

switches are
critical to your
operation. Not
only do they
help protect your
people from injury,
they help protect
your equipment
and processes and minimize the risk of costly downtime
and repairs. You need high power switches that are reliable,
enduring and that thrive in harsh environments.
Our solution: Mersen offers a wide range of DC and AC high
power switches that are rigorously engineered and designed
to handle high current/low voltage and high voltage/low current
applications. And when you need more than just a switch,
Mersen’s world-class engineering team is ready to provide
custom engineering and fabrication to build the high power switch
system or assembly you need, exactly the way you need it.
Want more information fast? For more technical or
application-specific information, please call our High Power

High Power Switches

• Berg HA Range 1500V DC LV
Disconnect Switch..............................L2
• Berg HUVS Range 3.6kV MV
Changeover Disconnect Switch.........L3
• Berg HAS Range 12kV MV
Disconnect Switch..............................L4
• Berg HAS Range 24kV MV
Disconnect Switch..............................L5
• Berg HAS Range 36kV MV
Disconnect Switch..............................L6
• Fouilleret NORD 1500VDC Disconnect
Switch.................................................L7
• Soule PBD 2000V DC Disconnect
Switch.................................................L9
• Hundt & Weber HSE-HSD Electrolytic
Cell Disconnect Switch..................... L11

Switch experts, at 978-462-6662; 416-252-9371 in Canada; or

• CBC Modular Bar Contactors...........L12

visit our website at us-ferrazshawmut.mersen.com.

• CEX Field Excitation Contactors....... L13
• Colomix 71.......................................L14
• Systems Capability...........................L15

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

L

High power

HA Range 1500V DC LV Disconnect Switch
Berg 1500V DC Disconnect Switch
Our HA switch style is a high quality, extremely robust product. This safety device is
simple, transparent to the network, and reliable over time in all environments.
It is a safety device with a visible blade opening and is used for maintenance of major
electrical installations. The switch may also be customized to customer requirements
regarding number of poles and poles spacing.

Features/Benefits:
•• Large air isolation and creepage distance
•• Self-cleaning blade contacts
•• Positive opening and visible break
•• Rugged anti-torsion construction
•• Large customization with: manual, motor & pneumatic drives;
auxiliary switches; solenoid interlocks
•• Adaptable mounting dimensions

Ratings:

Highlights:

Applications:

•• No-load operation

•• Battery disconnect

•• Indoor type – vertical mounting only

•• Grounding switch

•• Mechanical endurance: ≤ 1kA =

•• Motor isolation

25,000 cycles; >1kA = 50,000
cycles (open/close)

Amps	 : 100A to 3750A

•• 3rd rail sectionalization for
Transit use

•• 130° C maximum temperature
without damage to the switch
•• Electrical contact through silver
plated electrolytic copper blades
with pressed on hard silver
contact rivets and silver plated
copper alloy castings
•• Supporting insulators made
of cast epoxy resin (UL94-V1

Approvals:
•• Designed according to IEC
62271

flammability classification)

Please contact our application team at technicalservices.nby@mersen.com or
978-465-4853 for suitable solutions to your requirements.

L2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

HUVS Range 3.6kV MV Changeover Disconnect
BERG 3.6 kV AC / DC MV Changeover Switch
The changeover disconnect’s unique design transfers power from one single source
to two or three loads in one switch body using one shaft, eliminating the need for
costly and non-safe interlocks systems. It is a safety device with a visible blade
opening and is used for maintenance of major electrical installations. The electrical
contact is made with silver contacts, which provide strong mechanical endurance up to
50,000-cycles.

Features/Benefits:
•• Positions 1-2 (1-0-2 on request)
•• Large isolation air and creepage distance
•• Self-cleaning blade contacts
•• Positive opening and visible break
•• Rugged anti-torsion construction
•• Large customization with: manual, motor & pneumatic drives;

Ratings:

auxiliary switches; solenoid interlocks

Amps	 : 400A to 6300A

Highlights:

Applications:

•• No-load operation

•• Battery disconnect

•• Indoor type – vertical mounting

•• Grounding switch
•• Transfers power between

only

furnaces

•• Mechanical endurance: ≤ 1kA =
25,000 cycles; >1kA = 50,000
cycles (open/close)
•• 130° C maximum temperature
without damage to the switch
•• Electrical contact through silver
with pressed on hard silver

Rated power frequency withstand voltage,
1 min, 50 Hz

contact rivets and silver plated

Phase to earth and between poles (kV)

10

copper alloy castings

Across the isolating distance (kV)

12

Approvals:
•• Designed according to IEC 62271

L

plated electrolytic copper blades

Rated lightning impulse withstand voltage (BIL)

•• Supporting insulators made
of cast epoxy resin (UL94-V1
flammability classification)

Phase to earth and between poles (kV)

40

Across the isolating distance (kV)

46

Electrical Characteristics:
Rated continuous current (A) - AC

400

630

1000

1600

2000

3150

4000

6300

Rated continuous current (A) - DC

400

630

1250

1900

2400

3750

5300

7500

26

26

40

52

63

71

71

81

65

65

100

130

160

177

177

214

Rated short-time withstand current (rms)
1 sec (kA)
Rated peak withstand current, 50 Hz (kA)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

L3

HAS Range 12kV MV Disconnect Switch
The BERG 12 kV AC Disconnect Switch is a robust product
This safety device is simple and transparent to the network, and reliable over
time in all environments. Our specially designed pressure systems require low to
no maintenance. It is a safety device with a visible blade opening and is used for
maintenance of major electrical installations. The electrical contact is made with silver
contacts, which provide strong mechanical endurance up to 50,000-cycles.

Features/Benefits:
•• Large air isolation and creepage distance
•• Self-cleaning blade contacts
•• Positive opening and visible break
•• Rugged anti-torsion construction
•• Large customization with: manual, motor & pneumatic drives; auxiliary
switches; solenoid interlocks
•• Adaptable mounting dimensions

Highlights:

Applications:

•• No-load operation

•• Generator isolation

•• Indoor type – vertical mounting

•• Transformer isolation

only

•• Grounding switch

•• Mechanical endurance: ≤ 1kA =

•• Tie switch

25,000 cycles; >1kA = 50,000

•• Medium Voltage drive

cycles (open/close)

•• Furnace applications

•• 130° C maximum temperature
without damage to the switch
•• Electrical contact through silver
plated electrolytic copper blades

Rated power frequency withstand voltage,

with pressed on hard silver

1 min, 50 Hz

contact rivets and silver plated

Phase to earth and between poles (kV)

28

copper alloy castings

Across the isolating distance (kV)

32

•• Supporting insulators made

Approvals:
•• Designed according to IEC
62271

Rated lightning impulse withstand voltage (BIL)

of cast epoxy resin (UL94-V1

Phase to earth and between poles (kV)

75

flammability classification)

Across the isolating distance (kV)

85

Electrical Characteristics:
Ampere Rating (A) - AC
Rated short-time withstand current (rms)
1 sec (kA)
Rated peak withstand current, 50 Hz (kA)

L4

400

630

1000

1600

2000

3150

4000

6300

8000

12000

20

20

40

52

63

71

71

81

110

121

50

50

100

130

160

177

177

214

275

300

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

HAS Range 24kV MV Disconnect Switch
BERG 24 kV AC MV Disconnect Switch
This is a high quality, extremely robust AC disconnect switch. This safety device is
simple, transparent to the network, and reliable over time in all environments. Our
specially designed pressure systems require low to no maintenance. It is a safety
device with a visible blade opening and is used for maintenance of major electrical
installations. The electrical contact is made with silver contacts, which provide strong
mechanical endurance up to 50,000-cycles.

Features/Benefits:
•• Large air isolation and creepage distance
•• Self-cleaning blade contacts
•• Positive opening and visible break
•• Rugged anti-torsion construction
•• Large customization with: manual, motor & pneumatic drives; auxiliary
switches; solenoid interlocks
•• Adaptable mounting dimensions

Highlights:

Applications:

•• No-load operation

•• Generator isolation

•• Indoor type – vertical mounting

•• Transformer isolation

only

•• Grounding switch

•• Mechanical endurance: ≤ 1kA

•• Tie switch

= 25,000 cycles; >1kA = 50,000

•• Medium Voltage drives

cycles (open/close)

•• Furnace applications

•• 130° C maximum temperature
without damage to the switch
•• Electrical contact through silver
Rated power frequency withstand voltage,

Approvals:

1 min, 50 Hz

with pressed on hard silver
contact rivets and silver plated
copper alloy castings

Phase to earth and between poles (kV)

50

Across the isolating distance (kV)

60

•• Designed according to IEC

L

plated electrolytic copper blades

62271

Rated lightning impulse withstand voltage (BIL)

•• Supporting insulators made
of cast epoxy resin (UL94-V1
flammability classification)

Phase to earth and between poles (kV)

125

Across the isolating distance (kV)

145

Electrical Characteristics:
Rated continuous current (A) - AC
Rated short-time withstand current (rms)
1 sec (kA)
Rated peak withstand current, 50 Hz (kA)

400

630

1000

1600

2000

3150

4000

6300

8000

12000

26

26

30

37

58

64

64

77

100

110

65

65

75

91

144

159

159

193

250

275

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

L5

HAS Range 36kV MV Disconnect Switch
BERG 36 kV AC Disconnect Switch
The HAS Range Low Voltage Disconnect Switch is a high quality, extremely robust
product. This safety device is simple, transparent to the network, and reliable over
time in all environments. Our specially designed pressure systems require low to
no maintenance. It is a safety device with a visible blade opening and is used for
maintenance of major electrical installations. The electrical contact is made with silver
contacts, which provide strong mechanical endurance up to 50,000-cycles.

Features/Benefits:
•• Large air isolation and creepage distance
•• Self-cleaning blade contacts
•• Positive opening and visible break
•• Rugged anti-torsion construction
•• Large customization with: manual, motor & pneumatic drives; auxiliary
switches; solenoid interlocks
•• Adaptable mounting dimensions

Highlights:

Applications:

•• No-load operation

•• Generator isolation

•• Indoor type – vertical mounting

•• Transformer isolation
•• Grounding switch

only

•• Tie switch

•• Mechanical endurance: ≤ 1kA =
25,000 cycles; >1kA = 50,000

•• Medium Voltage drives

cycles (open/close)

•• Furnace applications

•• 130° C maximum temperature
without damage to the switch
•• Electrical contact through silver
plated electrolytic copper blades

Rated power frequency withstand voltage,1 min, 50

with pressed on hard silver

Hz

contact rivets and silver plated

Phase to earth and between poles (kV)

70

copper alloy castings

Across the isolating distance (kV)

80

•• Supporting insulators made

Approvals:
•• Designed according to IEC
62271

Rated lightning impulse withstand voltage (BIL)

of cast epoxy resin (UL94-V1

Phase to earth and between poles (kV)

170

flammability classification)

Across the isolating distance (kV)

195

Electrical Characteristics:
Rated continuous current (A) - AC
Rated short-time withstand current (rms)
1 sec (kA)
Rated peak withstand current, 50 Hz (kA)

L6

400

630

1000

1600

2000

3150

4000

6300

8000

12000

26

26

30

37

58

64

64

77

100

110

65

65

75

91

144

159

159

193

250

275

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

NORD DC Disconnect Switch 1500VDC
Fouilleret NORD DC Disconnect Switch
The NORD is a high quality, extremely robust product. This safety device is simple,
transparent to the network, and reliable over time in all environments. The NORD is
a deformable switch, which moves with the expansion and retraction of the busbar
system, eliminating the need for flexible shunt connections. Its individual spring
system helps to distribute the current throughout the switch, and provides a very low
and constant voltage drop. The NORD DC Disconnect Switch is mainly used with
copper busbar systems. The NORD switch is bolted directly to the busbar with bolted
copper connections for easy installation. The electrical contact is made with silver
contacts, which provide strong mechanical endurance up to 50,000-cycles.

Features/Benefits:
•• Visible break by direct seeing of the mobile silver-plated copper contacts
•• Mechanically independent mobile contact arms with high-pressure springs
•• Electrical contact with silver to silver contact
•• Insulation with Fiberglass reinforced polyester insulators
•• Operation mechanism of bichromate galvanized steel by a toggle closed

Ratings:
Amps	 : 14kA to 140kA

system
•• Disconnects are self-supporting. Busbar support must be sized to
withstand the disconnect’s additional weight
•• Upon request, choice of input and output terminals in aluminium or silverplated copper
•• Upon request, two-poles or change-over design by side association of two
disconnects

Applications:

•• Accepts busbar dilatations thanks

•• Output rectifier isolation

to built-in deformability (flexible

•• Large power supply disconnect

shunts are not necessary)
•• Low and constant voltage drop

Approvals:
•• Designed according to IEC

•• Self-cleaning effect on contact

60947-3 / IEC 60077-1 (NFF

•• High short-circuit current

16101 / 16102)

L

Highlights:

withstand
•• Large insulation and creepage
distances
•• Easy connections to:
- Aluminum busbar by welding
- Copper busbar by bolting
•• Large customization possible with:
- Actuators (motor, pneumatic,
manual)
- Auxiliaries (limit switches,
locks, control boxes)
- Adaptation to the connecting
busbar.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

L7

Fouilleret NORD DC Disconnect Switch 1500VDC
Main Technical Characteristics
Electrical Data:
•• Temperature rise at nominal current (with 40°C max. Ambient temperature)
less than : 65°C
•• Typical temperature rise at nominal current (with 40°C max.) : 15°C above
busbar
•• Typical voltage drop at nominal current : 30 mV
•• Peak short-circuit current withstand (upon circuit configuration)
- In one pole configuration : 10 x (Nominal current)
- In two poles configuration : 5 x (nominal current)
•• Dielectric withstand strength
- Between live parts in open position : 10 kV - 50 Hz - 1 min
- Between live parts and earth : 10 kV - 50 Hz - 1 min
- Between auxiliary contacts and earth : 2.5 kV - 50 Hz - 1 min
- Between motor and earth : 2 kV - 50 Hz - 1 min
•• SCR leakage current breaking capacity (upon request) : 1 A - 100 V DC
•• Power breaking capacity up to 100 kA - 100 V DC - L/R < 20 msec : Upon
request

Mechanical Data:
•• Mechanical endurance (with respect to maintenance instructions) : 20,000
cycles
•• Typical duration of opening or closing operation:
- With motor operation : 3 to 12 seconds
- With pneumatic operation : Less than 1 second
•• Ponctual temperature withstand without equipment damage : 140°C

L8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Soule PBD 2000V DC Disconnect Switch
Soule PBD DC Disconnect Switch
The PBD DC Disconnect Switch is a high quality, extremely robust product.
This safety device is simple, transparent to the network, and reliable over time
in all environments. Our PBD is a deformable switch, which will move with the
expansion and retraction of the busbar system eliminating the need for flexible shunt
connections. The PBD is mainly used with and welded directly onto aluminum busbar
systems. The electrical contact is made with silver contacts, which give it a strong
mechanical endurance with very good electrical data.

Features/Benefits:
•• Visible break
•• Aluminum welded connections
•• Absorbs dimensional variations due to expansion (flexible shunts are not
necessary)
•• Low and constant voltage drop

Ratings:

•• Supported by busbar (no frame required)

Volts	

•• Possibility of covering up totally one side of the disconnect (for protection

Amps	 : 20kA to 140kA

: 2000V DC

& isolation)
•• Easy connections by welding to high section aluminium busbar
•• Large customization possible with:
•• Actuators (motor, pneumatic, manual)
•• Auxiliaries (limit switches, locks, control boxes)
•• Adaptation to the connecting busbar

Highlights:

Applications:

•• Accepts busbar dilatations thanks

•• Output rectifier isolation
•• Large power supply disconnect

shunts are not necessary)
•• All contacts are fitted with solid
silver, high temperature brazed
(special process)

Approvals:
•• Designed according to IEC

L

to built-in deformability (flexible

60947-3 / IEC 60077-1

•• Mechanically independent mobile
contact arms with high-pressure
springs
•• Electrical contact with solid pure
silver, point to point, contact tips.
•• Operation mechanism by a toggle
closed system
•• Upon request, two poles or
change-over design by side
association of two disconnects

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

L9

Soule PBD 2000V DC Disconnect Switch
Main Technical Characteristics
Electrical Data:
•• Temperature rise at nominal current (with 40°C max. Ambient temperature) less
than : 65°C
•• Voltage drop at nominal current less than : 60 mV
•• Peak short-circuit current withstand (upon circuit configuration) : 8 x (Nominal
current)
•• Dielectric withstand strength:
- Between live parts in open position : 10 kV - 50 Hz - 1 min
- Between live parts and earth : 10 kV - 50 Hz - 1 min
- Between auxiliary contacts and earth : 2.5 kV - 50 Hz - 1 min
- Between motor (AC) and earth : 2 kV - 50 Hz - 1 min

Mechanical Data:
•• Built-in deformability (longitudinally (dL) / transversally (dT) / axially (dA)) : 20 / 20 /
20 mm (higher values available upon request)
•• Mechanical endurance (with respect to maintenance instructions).
•• Higher endurance upon : 1000 Cycles
•• Typical duration of opening or closing operation:
- With motor operation : Less than 20 seconds
- With pneumatic operation : Less than 1 second
•• Ponctual contact temperature on live parts withstand without equipment damage :
140°C

L10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

HSE-HSD Electrolytic Cell Disconnect Switch
Hundt & Weber DC Disconnect Switch
The HSE/HSD Electrolytic Cell Disconnect Switch allows for installation in any
position directly into the busduct system without further fixation. One side of the
switch is equipped with flexible connectors, thus no further expansion joints are
needed. The other side has solid busbar. The design of the switch (ball bearings
supporting main switching shaft) and the slight travel of the contacts while switching,
require minimal operating force. Thus easy manual operation is possible, or operation
by means of a direct acting motor operator with little power consumption. The high
current isolators, HSE/ HSD, consist of a system with one or more integrated,
encapsulated contact modules. One module is normally rated for a current of 6,000A.
If higher ratings are required, adequate numbers of contact modules are connected
in parallel and operated with a common mechanism. The principal elements of the
switch are standardized, encapsulated contacts, which consist of two connector
plates, a high-elastic bellow, and the contacts. These contacts are made of silver alloy
with very good electrical data.

Ratings:
Amps	 : 6kA to 60kA

Features/Benefits:
•• Complete encapsulated main contacts
•• High mechanical strength
•• Corrosion proofed
•• Little operation torque
•• Position insensitive
•• Positive opening
•• Low contact resistance
•• Low voltage drop
•• Low contact heating
•• Extreme high electrical and mechanical durability
•• Safe operation, even under extreme ambient temperature
•• Adaptation to the connecting busbar

•• Designed according to VDE

Highlights:

Applications:

•• Accepts busbar dilatations thanks

•• Output rectifier isolation

to built-in deformability (flexible
shunts are not necessary)
•• Very compact switch

Approvals:
L

•• Auxiliaries (limit switches, locks, control boxes)

0110 Gr. C/IEC 60947

•• Cell isolation for electrolytic
process
•• Large power supply disconnect

•• Electrical contacts are
encapsulated, protecting them
from corrosive atmosphere like
chlorine or salt
•• Easy connections to bolted copper
busbar
•• Large customization possible with:
- Actuators (motor, pneumatic,
manual)
- Auxiliaries (limit switches, locks,
control boxes)
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

L11

CBC Modular Bar Contactors
Elec CBC Bar Contactor: 80 – 6200A
The CBC Bar Contactor is ideal for use in DC applications including; lifting magnets,
lifts, electroplating, the iron and steel industry for traction (rolling stock), motor
controls, and hoisting equipment, and other applications in harsh conditions. Thanks
to its modular constitution, the CBC Bar Contactor from 80 to 6200A can meet most
of the requirements that block contactors, although easy to mount, can not.

Features/Benefits:
•• Mechanical latching with single or double electrical release (does not
change the total dimensions of the contactor).
•• Self-protective device for the release coil(s).
•• Metallic support for Kirk Key-type lock (lock not supplied).
•• Horizontal or back-to-back mechanical locking.
•• Poles of different calibers and supplied with different currents.
•• Poles without magnetic blowout.

Ratings:

•• Reinforced insulation.
•• Double insulation for specific applications.
•• Tropical treatment n° 2

Highlights:

Applications:

•• 1 to 4 single main poles (2 poles

•• Electrochemistry - galvanoplasty

for calibers 4000 and 5000)
with copper contact (silver pad

: 500V to 1500V

Amps	 : 1250 to 8000A

(reversing polarities),
electroplating, etc.

contact on request or for specific

•• Lifting magnets and lifts

applications).

•• Hosting equipment such as

•• Arc-blowout coil operates only

Volts	

cranes or overhead cranes
•• Motor control, rolling mills

during opening.
•• Closing electromagnet mounted
on the right side of the poles (on
request, it can be mounted on the

accessories, “Blooming Mills,”
mining industry
•• Motor controls in foundry industry

left), solid iron magnetic circuit

Approvals:
•• Designed according to VDE
0110 Gr. C/IEC 60947

with 2 coils.
- Control circuit supplied from
an AC source via a rectifier
and power-saved coils (device
mounted and cabled on the
contactor).
- Control circuit supplied from a
DC source with power saved coils
(device mounted and cabled on
the contactor

L12

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

CEX Field Excitation Contactors
Elec CEX Field Excitation Contactor: 80 – 5000A
The CEX Field Excitation Contactor is used to switch on and cut off the excitation
circuit of a machine, inserting a discharge resistor at the terminals of the inductor at
the time of the break. The CEX Field Excitation Contactor is for the excitation and
de-excitation of power inductors up to 900MW and more. The CEX Contactors are
made up of 1, 2 or 3 magnetic arc-blow-out poles and of one opening pole called a
“rupturing pole.” On opening, the rupturing pole closes before the main poles open.

Features/Benefits:
•• Bar contactor is adaptable to customer needs regarding options for high
mechanical strength and number of operations
•• Electrical or mechanical latching
•• Variety of auxiliary contacts

Highlights:

Applications:

•• 1, 2 or 3 magnetic arc-blow-out

•• Power generator excitation

contactor poles:

systems

- silver alloy contacts for caliber

Ratings:
Volts	

: 110 to 2000 VDC

Amps	 : 80 to 6200A

80 to 5000 A.
- copper contacts (on request).
•• One magnetic arc-blow-out
dosing pole without mechanical
overlapping with the contactor
poles.
•• One mechanical latching with
single or double electrical release.
•• Magnetic circuit for over-excited
coil supplied with DC current:

separately.
- Opening: one NO contact

Approvals:
•• Designed according to VDE

L

- Closing: economy resistor for
caliber 80 to 200A, delivered

0110 Gr. C/IEC 60947

connected in series with the coil
opening at the same time as the
contactor.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

L13

Colomix 71
Elec Colomix 71 for the replacement of old asbestos arc chutes.
No one needs to explain how harmful asbestos is. For years people working in all types
of industries were exposed to it. Electrotechnology was no exception: asbestos cement
was widely used for its excellent thermal and mechanical characteristics. With Colomix
71, we developed a material that presents no hazard to human health, is easy to work
with, has excellent mechanical strength and can be machined to any shape. Colomix
71 has the thermal and insulating properties to withstand extremely high temperature
densities and dissipate electric arcs. In fact, replacing asbestos blow-out cages
with Colomix 71 leads to better performance. Colomix 71 is a mineral insulator for
electrical and thermal applications consisting of 59% hydrated aluminum silicate, 38%
wollastonite (calcium silicate) and 3% glass fiber. It has excellent mechanical strength
at high temperatures (600°C). “S” grade is recommended for electrical applications.
Finished parts of that grade are impregnated with high temperature resin.

Features/Benefits:
Colomix 71 is a patented product that is designed to aid in the replacement
of cement-asbestos blow-out cages equipping contactors created by an older
generation of manufacturers. With Colomix 71, you can create an indentical match
of your existing blow-cages, while maintaining the equipment’s genuine technical
characteristics. This innovative material allows you to replace existing blow-cages,
without launching a long and expensive R&D study. With Colomix 71 there is no
need to change the whole breaking system (circuit breaker, switch, etc.) — only the
old blow-out cages with their asbestos shell need to be replaced. The Colomix 71
offers an easy solution to maintenance and asbestos compliance.

Highlights:
This new generation of blow-out cages is 100% compatible with existing contactors.
It does not downgrade the contactors in any way, ensuring their perennity. In addition,
breaking capacities are notably improved due to a reduction in breaking times.
Colomix 71 is available in three forms:

Applications:
•• Replacement of all old asbestos
arc chambers and arc chutes

• 1000x1000 mm sheets in its standard version
(930x830 mm available only on request)
• Parts to be machined per customers’ drawings, sample or specification
• Molded parts

L14

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Systems Capability
When you need more than just a switch, our world-class engineering team is ready
to provide custom engineering and fabrication to build the High Power Switch system
or assembly you need, exactly the way you need it. We can design and build an

Applications:

enclosure for our high power switch products that meets your specific requirements
— either in a metallic or polyester fiberglass enclosure, wall mounted or floor
mounted, and with controls, if needed. Our team of design engineers are bold problemsolvers and enjoy meeting your High Power Switch challenges head on with innovative
engineering and creative solutions. Our engineers incorporate design and construction
features that ensure each switch performs reliably, whether it’s a rectifier output switch
operated once a year or a change-over switch system in an enclosed panel actuated
dozens of times a day.

Features/Benefits:
•• Customized enclosure to fit your specification
•• Customize controls as per your requirements

•• Fuse Cabinet (above)
•• Street Lighting Control (below)

•• Positive opening and visible break
•• Rugged anti-torsion construction
•• Large customization with: manual, motor & pneumatic drives; auxiliary
switches; solenoid interlocks
•• Adaptable mounting dimensions

Highlights:
•• Metal or fiberglass
•• Local or remote controls

•• Power Distribution Changeover
Switch (below)

•• Viewing windows
•• Floor, wall or pole mount

Approvals:
L

•• Designed as per UL, CSA, ANSI/IEEE Standards
Please contact our application team at technicalservices.nby@mersen.com or
978-465-4853 for suitable solutions to your requirements.

•• Enclosed Medium Voltage
Disconnect (below)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

L15

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Thermal Management
Innovative air & liquid cooled heatsinks and cooling systems

Your problem:
You need to
protect critical
semiconductor
and power

M	 Thermal Management
Air Cooled

electronic

• FabFin® Heatsink..............................M2

systems from

• Hollowfin® Heatsink...........................M9

heat generated
during high power
applications.

• Mixed Metals Heatsink....................M10
• Integrated Modules......................... M11
• Copper Heatsink.............................M12

Our solution: Mersen offers innovative thermal management
solutions. We deliver patented cooling technology that absorbs
and dissipates heat from critical components. Our innovative

• Dual Base Plate Heatsink...............M13
• Extrusion Heatsink..........................M14

Fabfin® product was the first “glueless technology” for high

• Heatpipes........................................M15

performance, high ratio heatsink solutions. Our pioneering

• Embedded Heatpipes......................M16

products can be found in a wide range of applications and
industries including, industrial controls, motor drives, power
controls, transportation, communication, medical, solar power
and wind power.

Liquid Cooled
• Aquasink® Heatsink.........................M17
• Aquamax® (Copper) Heatsink ........M19
• Aquasurf® Heatsink.........................M20

free 3D Thermal Modeling software on our website, click Resources & select R-tools. For quotes or questions on heatsinks

• Aquamax® (Aluminum) Heatsink.....M21
Cooling

and cooling systems, email us at sales.mis@mersen.com or

• Press-Pack Coolers........................M22

contact applications support at 905-795-0077 x258 or x340. You

• Cooling Systems.............................M23

may also visit our website at us-ferrazshawmut.mersen.com

• Product Materials & Tolerances......M24

and click “Products > Product Data >Thermal Management.”

• R-Tools® 3D Heatsink Modeling......M26

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M

Want more information fast? Take advantage of R-Tools® - our

Air Cooled Fabfin

®

Heatsink

The first patented “glueless technology” air cooled
Fabfin is a fabricated air cooled heatsink with a height-to-fin spacing ratio greater than
an extruded section. Fabfin can be supplied essentially of any size where a multitude
of aluminum fins of varying heights and thickness are attached by a swaging process
to an aluminum base plate of variable thickness, length and width, on four standard
fin spacings. These standard spacings are designated as an FF (8.51 mm), DF (6.86
mm), AF (5.49 mm), or MF (3.43 mm) series. Typical alloy is 6063 for both fins and
base plate. Finishes are numerous. No glue is used in the process.
Performance can be modeled within R-Tools.

Features/Benefits:
•	Fabricated
•	 Multiple fins joined to baseplate by swaging process
•	 Metal to metal construction. Al/Al Cu/Al Cu/Cu
•	 Immensely rugged

Performance:

•	 No epoxy/glue used in fabrication process

•	 Typically 15% lower thermal

•	 No thermal barrier at fin to baseplate join

impedance than a glued

•	 Fin height to spacing ratio much greater than extruded section
•	-400C to + 3500C storage and operating range

solution
•	Can be modeled on R-Tools

•	 Capable of withstanding extensive vibration
•	 Tongue and groove construction
•	 Baseplates can be welded together with fins attached

Highlights:

Applications:

•	Essentially any width, length

•	Communications
•	 Industrial controls

or height
•	 Any fin height to spacing ratio

•	 Medical, Military
•	 Motor drives

up to 46:1
•	 Anodize finish

•	 Power controls

•	Chromate finish: Hexavalent +

•	 Solar energy
•	Transportation

Trivalent
•	 Electroless nickel finish

•	 Wind energy

•	 Selective use of copper fins

M2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Air Cooled Fabfin

®

Heatsink

What you need to know about Fabfin Heatsinks
Welcome to the amazing potential of

Configuration 1

Fabfin. The design engineer can now

(without mounting flanges: all slots filled)

leap beyond the limitations of low

• L = Lƒ =1250

ratio one piece aluminum extrusions

• W = [Wƒ + (2 x shoulder)] = Wmax (see
Fig. 1 Table 2)

and the thermal barriers of epoxy
assemblies by using Fabfin — the high
ratio, high performance, immensely
rugged, thermal barrier-free aluminum
heatsink assembly. Within a broad

Configuration 1

possibilities to address your most

Configuration 2

challenging thermal applications.

(with mounting flanges; exposed fin slots)
• L = (Lƒ + Y1 + Y2) =1250

All configurations

• If flanges Y1 and Y2 = 0, then Lƒ = L

• L = Length of baseplate		

• X1 may equal X2 but both must be

• Lƒ = Length of fin
Configuration 2

• Wƒ = Width over fins

specified
• W = (Wƒ + X1 + X2) = Wmax (see Fig. 1
Table 2)

• T = Thickness of baseplate

• Flanges X1 and X2 must be ≥ 2.5 mm for

• Tƒ = Thickness of flange

MF, ≥ 3.5 mm for AF, DF and FF
• Y1 may equal Y2 but both must be

• Baseplate thickness:

specified

9 mm Min

• Number of fins = Width indicator (N)

64 mm Max

corresponding to Wƒ (see formulas in
Table 3)

each family will be provided
by shearing the next taller
fin. If quantities dictate we
will tool a new fin.
• Max fin height 118 mm
except MF which is 49 mm
tall. MF equivalent fins can
be achieved by selecting the
Hollowfin on 6.86 mm centers.

Configuration 3
Note: Configurable aluminum
air cooled assemblies.
Four series organized on
baseplate slot spacing. Highly
flexible width, length and fin
arrangement.
Copper options available.

Configuration 3
(with mounting flanges; machined
surfaces)
• L = [Lƒ + Y1 + Y2 + (2 x 2.5)] =1250
• If flanges Y1 and Y2 = 0, then Lƒ = L
•X1 may equal X2 but both must

M

• Non-tooled fin height within

®

• Shoulder Width ≥ 2.5 mm for MF, 3.5 mm
≥ AF, DF and FF

mechanical envelope lies unlimited

• W = Width of baseplate		

• Number of fins = Width indicator (N)
corresponding to W (see formulas in
Table 3)

be specified
• W = [Wƒ + X1 + X2 + (2 x shoulder)] =
Wmax (see Fig. 1 Table 2)
• Flanges X1 and X2 must be specified
beyond 2.5 shoulder for MF and 3.5 mm
for AF, DF and FF
• Y1 may equal Y2 but both must be
specified
• Number of fins = Width indicator (N)
corresponding to Wƒ (see formulas in
Table 3)
• Tƒ must be = T – 3.3 in order to remove
the fin slots

For more product information visit us-ferrazshawmut.mersen.com > Products > Product Data > Thermal Management.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M3

Air Cooled Fabfin

®

Heatsink Configurator

9-easy steps to configure a Fabfin
The following represents a sample configuration of Figure 3,
page 6

STEP 1: Select a series
Select a series for a fin pitch.
Table 1: Fin Pitch
Fin Pitch (CC)

Series

(Center to Center)

MF

3.43 mm

AF

5.49 mm

DF

6.86 mm

FF

8.51 mm

Configuration 1

Fig. 2

Table 1 (above) and Fig. 1 (below) show the four standard

STEP 2: Select a configuration

Fabfin series based on Fin Pitch (CC). Variables within each

All Fabfin baseplates can be configured with or without a

series include length, width and thickness of baseplate as well

mounting flange. To define the configuration see detailed

as height and thickness of fins.

diagrams on page 3. If configuration 2 or 3 are selected please
specify the x and y coordinates for the mounting flange area.

Part Number Example: FF
Configuration 1
* fully populated, full length fins and without mounting flanges-

Fig 1
MF

AF

all slots filled
Configuration 2
* unmachined exposed flange(s)
Configuration 3
* machined exposed flange(s)

DF

FF

Part Number:
Configuration 1 = no digit required
Configuration 2 = 2
Configuration 3 = 3

*(if configurator 2 or 3 is selected the digit/code appears at
the very end of the product number)

Part Number Example: FF

M4

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Air Cooled Fabfin

®

Heatsink Configurator

STEP 3: Select a total length
Select the total length in mm *(this is user defined)
eg. L = Lƒ = 300 mm
Part Number Example: FF300

STEP 4: Select a baseplate thickness
(refer to Table 2)
All Fabfin heatsinks are available with standard 12.7
mm baseplate thickness but many other thicknesses

Table 2 (a-d) Baseplate Thickness
Table 2a - MF Baseplate Options
Thickness Reference

Thickness T (mm)

T13

12.7

T00

to be specified

Maximum Width
Wmax(mm)
Up to 305 mm

Table 2b - AF Baseplate Options
Maximum Width

Thickness Reference

Thickness T (mm)

T10

9.9

Up to 222 mm

T13

12.7

Up to 524 mm

T15

14.9

Up to 524 mm

slotting of the baseplate. New tooling is coming on-

T19

19.0

Up to 343 mm

line continuously and we may be able to supply your

T00

to be specified

are tooled. The baseplate thickness is typically
governed by the mechanical, thermal and cost
requirements of the application. Custom baseplate
thicknesses can be provided within the range of 9
mm to 64 mm by cutting new extrusion dies or gang

Wmax(mm)

special needs at no additional cost.
Part Number Example: FF300T13

Table 2c - DF Baseplate Options
Maximum Width

Thickness Reference

Thickness T (mm)

T10

9.5

Up to 310 mm

T13

12.7

Up to 524 mm

T14

14.2

Up to 337 mm

T15

15.3

Up to 524 mm

T17

17.3

Up to 324 mm

T18

18.3

Up to 400 mm

T00

to be specified

Wmax(mm)

Thickness Reference

Thickness T (mm)

T13

12.7

T00

to be specified

Maximum Width
Wmax(mm)
Up to 520 mm

For more product information visit us-ferrazshawmut.mersen.com > Products > Product Data > Thermal Management.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M

Table 2d - FF Baseplate Options

M5

Air Cooled Fabfin

®

Heatsink Configurator

STEP 5: Select a baseplate material
Choose one of the following materials: A = Aluminum
C = Copper
Part Number Example: FF300T13A

Table 3 (a-d) Width Indicator
Table 3a - Standard Tooled Baseplates
Width Indicator N

Width Fin to Fin (mm) Wf

127

36

121.4

202

58

196.8

To convert baseplate width to width indicator, select desired

237

68

231.1

baseplate total width (W). To determine Width Indicator (N) use

264

76

258.6

the formula at the bottom of each series table. (refer to Table 3)

302

87

296.3

STEP 6: Determine width indicator (N)

i.e. If 	

W = 260 mm

	

N = 260 - 9.4

		-8.51
	

Width (mm) W

Table 3b - AF Standard Tooled Baseplates

= 29.4 *(round up to the nearest integer)

Width Indicator N

Width Fin to Fin (mm) Wf

223

40

215.4

234

42

226.4

300

54

292.3

Alternatively go to the Fabfin configurator section on the

343

62

336.2

website for a complete listing of all widths and fin counts.

349

63

341.7

404

73

396.6

525

95

517.4

	

N = 30

Refer to Table 3 for standard tooled baseplate widths (W).

Mersen will manufacture this heatsink by machining the next

Width (mm) W

wider standard baseplate. (refer to Table 3d)

Fin count

Table 3c - DF Standard Tooled Baseplates

Configuration 1: Number of fins = Width indicator (N)
Configuration 2,3: Substitute Wƒ into the formula at the bottom
of each series in Table 3 to obtain fin count.
Wider widths are frequently supplied by welding Fabfin
assemblies together. The swaged fin to baseplate joint is
unaffected by the elevated welding temperatures.
Part Number Example: FF300T13A30
Fig. 3 Sample Heatsink

M6

Width (mm) W

Width Indicator N

Width Fin to Fin (mm) Wf

257

37

249.4

298

43

290.5

310

45

304.2

325

47

318.0

339

49

331.7

401

58

393.4

524

76

516.9

Table 3d - FF Standard Tooled Baseplates
Width (mm) W

Width Indicator N

Width Fin to Fin (mm) Wf

121

14

113.0

190

22

181.1

274

32

266.2

308

36

300.3

393

46

385.4

521

61

513.0

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Air Cooled Fabfin

®

Non-standard fin height within
each family will be provided
by shearing the next taller fin.
The exact fin height in
millimeters should substitute
the 000 in the Fin Reference
in Table 4. If quantities dictate
we will tool a new fin.
AC = Aluminum Corrugated
AS = Aluminum Serrated
AH = Aluminum Hollow
CF = Copper Flat
AF = Aluminum Flat

Table 4 (a-d) Fin Styles

Fig.4a
MF

MF

MF

Choose from the following
finishes:
C = RoHS compliant tri-valent
clear chrome
B = Black Anodize
A = Clear Anodize
D = Degrease only
Part Number Example:
FF300T13A30AC118B

Aluminum
Serrated (AS)

Cooper Flat
(CF)

Aluminum
Flat (AF)

AF

Aluminum
Serrated (AS)

AF

Cooper Flat
(CF)

AF

Aluminum
Flat (AF)

Fig.4c

Ratio H

H (mm)

to Space

AS035

Serrated

35

15:1

AS049

Serrated

49

20:1

AS000

Serrated

to be specified

AF000

Flat

to be specified

CF000

Flat

to be specified

Fin
Reference

Fin Style

Fin Height

Ratio H

H (mm)

to Space

AS037

Serrated

36.5

8:1

AS051

Serrated

50.5

11:1

AS091

Serrated

90.5

20:1

AS120

Serrated

119.5

27:1

AS000

Serrated

to be specified

AF000

Flat

to be specified

CF000

Flat

to be specified

DF

Aluminum
Corrugated
(AC)

Fin

DF

Aluminum
Serrated (AS)

DF

Aluminum
Hollow (AH)

FF

FF

Yes = L

Reference

Fin Style

Fin Height

Ratio H

H (mm)

to Space
13:1

AC071

Corrugated

71.4

AS071

Serrated

71.4

16:1

AC119

Corrugated

119.4

22:1

AS119

Serrated

119.4

26:1

AH060

Hollow

59.5

24:1

AH063

Hollow

63

25:1

AH085

Hollow

85

34:1

AH102

Hollow

101.8

40:1

AH119

Hollow

119.4

46:1

AC000

Corrugated

to be specified

AS000

Serrated

to be specified

AH000

Hollow

to be specified

Table 4d - FF Fin Options

No = no digit required

FF300T13A30AC118B

Fin Height

Table 4c - DF Fin Options

Choose legs if desired:

Part Number Example:

Fin Style

Table 4b - AF Fin Options

Fig.4b

Fig.4d
STEP 9: (Optional)

Fin
Reference

Part Number Example:
FF300T13A30AC118

STEP 8: Select a
finish

Table 4a - MKMF Fin Options

M

STEP 7: Select fin

To select fin material, style
and height, please refer
to Fig. 4 and Table 4 for
standard heights and fin
height ratios for each series.

Heatsink Configurator

Fin
Reference
Aluminum
Corrugated
(AC)

Aluminum
Serrated (AS)

Note: Take this part number and enter into R-Tools to simulate thermal performance using your selected interface
materials and semi-conductors. * (refer to Fig. 3 on page 6
for picture of this configured part FF300T13A30AC118B)

Fin Style

Fin Height

Ratio H

H (mm)

to Space

AC070

Corrugated

70

10:1

AS070

Serrated

70

11:1

AC118

Corrugated

118

17:1

AS118

Serrated

118

27:1

AC000

Corrugated

to be specified

AS000

Serrated

to be specified

For more product information visit us-ferrazshawmut.mersen.com > Products > Product Data > Thermal Management.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M7

Air Cooled Fabfin

®

Standards

The range of standard Fabfin®
forced convection cooled heatsinks
(FFC series) was developed to
incorporate standard 119mm square
axial fans. The fin spacing of 8.51
mm was selected to provide a 20:1
ratio, the practical heat transfer limit
for cooling Power Semiconductors
in typical ambient conditions. The
standard FFC series will accept 1,
2, 3 or 4 fans. Available in many
finishes. The serrated fin thickness
of 2.4mm provides near optimum
performance when using industry
standard axial fans. If some level of
performance de-rating is acceptable
(approximately 20%) then we
recommend that corrugated fins be
used. These have a thickness of 1.5
mm and are designated by ordering
the ‘AC’ part numbers. The use of
corrugated fins provides a weight
savings of approximately 15% and
will increase surface area by 7%
compared with a straight fin of the
same height. The push/pull (PP)
option is common for applications
where fan redundancy is important.
We recommend the use of ball
bearing fan(s), specifically for the
“pull” end, in order to maximize
the fan life due to the elevated
operating temperatures. The
additional weight of the fan can be
offset by using the corrugated fins,
if applicable. The adjacent graphs
provide a performance guide for heat
generating devices
ranging in size from point source to
60% coverage.

M8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Air Cooled - Hollowfin

®

Heatsink

The high fin density of the MF series with taller fins
The Hollowfin air cooled heatsink is characterized by the shape of its fins which
when mounted on the DF (6.86 mm) base plate effectively duplicates the high fin
density MF (3.43 mm) series, but with taller fins. A height to space ratio equivalent
to 46:1 occurs when the fin height is 118 mm. The Hollowfin is an ideal candidate to
be attached to a copper base plate to maximize performance. No glue is used in the
process.
Performance can be modeled within R-Tools.

Features/Benefits:
•	 All that apply to Fabfin®
•	 46 :1 fin height to spacing ratio at fin height of 118mm
•	 Highest performance all aluminum heatsink on the market
•	 No epoxy/glue used in fabrication process

Highlights:

Applications:

•	 Copper baseplate/Aluminum

•	 Communications

•	 Can be modeled on R-Tools

•	 Industrial controls
•	Medical
•	Military
•	 Motor drives
•	 Power controls
•	 Solar energy
•	Transportation
•	 Wind energy

M

fins available	

Performance:

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M9

Air Cooled Mixed Metals Heatsinks
Enhances heat spreading for high heat flux applications
Combination Fabfin® air cooled heatsinks are available with copper
baseplates for concentrated heat sources and aluminum baseplates with
copper fins for large area heat sources. Optimization is possible by mixing
both aluminum and copper fins.
The heatsink was developed to enhance heat spreading for those semiconductors developing high heat flux and limited allowable temperature rise. The
combination heatsink is offered on MF and AF fin spacing as a standard configurable
assembly. However, we do supply copper baseplates with DF (6.86 mm) spacing
using a Hollowfin which effectively provides MF fin spacing with fins up to 118 mm
high. No glue is used in the process.
Contact the Applications Department for Modeling Assistance at
905-795-0077 x258 or x340.

Features/Benefits:
•	
•	
•	
•	
•	
•	

All that apply to Fabfin®
Increased performance with use of copper

Performance:
• 	 Typically 15 - 25% lower
thermal impedance than a glued
solution
• 	Can be modeled on R-Tools

Selective use of copper and aluminum fins

with assistance of our

Copper baseplate and aluminum fins

Application Department

Aluminum baseplate with Cu or Al/Cu fins
Can also apply to dual baseplate

Highlights:
•	 Essentially any width, length or
height

M10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Air Cooled Integrated Heatsink Modules
A consolidated approach for maximum cooling
Typically power modules and amplifiers are attached to an air cooled heatsink with a
multitude of screws together with some form of TIM. The high thermal barrier at the
interface can be eliminated by swaging a multitude of fins into a thick base plate and
then machining the module features and requirements into the base plate.
Performance can be modeled within R-Tools.

Features/Benefits:
• 	 All that apply to Fabfin®
• 	 Thick baseplate is hogged out
• 	 Detailed internal machining

Highlights:

Applications:

• 	 Eliminates interface between

• 	Microwave
• 	 Military

Performance:
• 	 Can be modeled on R-Tools

M

power supply and heatsink

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M11

Air Cooled Copper Heatsinks
Maximum forced air cooling performance
An all copper Fabfin® heatsink provides maximum forced air cooling
performance. The fabrication process is the same as that for an aluminum
Fabfin heatsink and is offered on MF and AF fin spacing (3.43 mm and 5.49 mm
respectively). While copper provides outstanding performance, the overall cost is
high. Other fin spacing can be provided when fins are silver soldered into slots. No
glue is used in the process.
Performance can be modeled within R-Tools.

Features/Benefits:
• 	 All that apply to Fabfin®
• 	 Swaged or soldered
• 	 Fins can be taller than 118mm
• 	 Spacing is variable

Performance:

• 	 Fin thickness is variable
• 	 No epoxy/glue used in fabrication process

Highlights:

Applications:

• 	 Highest air cooled performance

• 	 Anywhere maximum performance

• 	 Can be modeled on R-Tools

is required but where weight is not
an issue

M12

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Air Cooled Dual Base Plate Heatsinks
Superb fin efficiency with a no-glue process
Dual base plate air cooled heatsinks (patented) increase fin efficiency with all
aluminum or copper/aluminum assemblies. Mixed metal fin arrangements as well as
dissimilar baseplates are available. Standard fin height, thickness and spacing are
available but few mechanical constraints limit height, width, spacing or thickness of
assembly. No glue is used in the process.
Performance can be modeled within R-Tools.

Features/Benefits:
• 	 All that apply to Fabfin®
• 	 Increased performance
• 	 Mixed metals can be used

Highlights:
•	 Increased fin efficiency by splitting
the thermal load

Performance:
• 	 Increased fin efficiency by
up to 30%

M

• 	 Can be modeled on R-Tools

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M13

Air Cooled Aluminum Extrusion Heatsinks
Aluminum extrusion air cooled heatsinks are the mainstay for cooling medium power
semiconductors. Many shapes are available to fit diverse applications. Thousands
of shapes exist in the marketplace. If you do not find your needs amid our existing
offerings, we will tool a new shape to meet your needs with minimum order quantities.
Performance can be modeled within R-Tools.

Features/Benefits:
• 	 Lowest cost	

M14

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Air Cooled Heatpipes
Spreading heat to large area cooling banks via heat pipes
High heat losses from Press-Pack and IGBT power devices can be spread to large
area cooling banks via heatpipes. Typical construction employs copper heatpipes and
aluminum or copper “Evaporator” and “Condenser” sections.
If electrical insulation is required ceramic insulators can be built into the
heatpipes. Working fluids are chosen to suit the application.
Full specifications can be found on our website.
Contact the Applications Department for Modeling Assistance
at 905-795-0077 x258 or x340.

Features/Benefits:
• 	 Increased surface area of cooling fins
• 	 Moves thermal load to high performance air cooled bank
• 	 Will transfer high thermal loads

Performance:
• 	 Heat transfer performance

• 	 Copper tube heatpipes

between air and liquid cooled

• 	 Working fluid options

• 	 Contact factory applications

• 	 Copper or aluminum evaporator

department

• 	 Copper or aluminum condenser

Highlights:

Applications:

• 	 Allows for maximum heat flux

• 	Those applications where typical
air cooled solutions cannot meet
demand and liquid cooling is

M

unacceptable

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M15

Air Cooled Embedded Heatpipes
The “hot spot” heat evaporator
Typical applications combine the high performance of Fabfin® and the heat
spreading of heatpipes. High heat flux in concentrated areas can be spread across
a heatsink by placing the hot spot over one end of the heatpipe which becomes the
“evaporator” and the heat is transferred to the cooler part of the heatsink where it
condenses releasing the heat to the heatsink.
Contact the Applications Department for Modeling Assistance at 905-795-0077
x258 or x340.

Features/Benefits:
• 	 Spreads thermal load
• 	 Surface embedded copper heatpipes
• 	 Integrated with Fabfin heatsinks
• 	 Epoxy interface

Performance:

	

M16

Highlights:

Applications:

• 	 No dimensional constraints

• 	 High flux heat sources

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

• 	 Contact factory applications
department

www.barr-thorp.com

Liquid Cooled Aquasink

®

Heatsinks

Robust construction for reliable performance.
The Aquasink liquid cooled heatsink employs an aluminum body and copper tubes.
These tubes are embedded in the aluminum body using a mandreling process that
expands the copper tube into intimate contact with the aluminum body creating a
very robust construction. A smear of specialty grease at the interface of copper and
aluminum prevents the possibility of dissimilar metal corrosion. Heat transfer is equal
from both mounting surfaces.
Performance can be modeled within R-Tools.

Features/Benefits::
• 	Aluminum body, straight copper tubes
• 	 Tubes expanded into intimate contact with aluminum body
• 	 Specialty grease prevents corrosion
• 	 Heat transfer equal from both mounting surfaces
• 	 Very rugged

Performance:
• 	 Can be modeled on R-Tools

	

Highlights:

M

• 	 Practically no physical limitations

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M17

Liquid Cooled Aquasink

®

About Aquasink heatsinks
The Aquasink heatsink has been developed to
provide the design engineer with a rugged, low
cost, high performance heatsink. This Aluminum/
Copper liquid cooled cold plate is suitable for high
power, isolated base semiconductors and other heat
sensitive components. Aquasink’s unique copper tube
mandreling technology provides intimate long term
contact of the tube with the aluminum cold plate. It is
impossible to loosen Aquasink’s copper tubes. The
integrity of an Aquasink tube is never compromised
by flycutting, guaranteeing that an Aquasink will

Heatsink Configurator

7 Easy steps to configure Aquasink
STEP 1: Select tube diameter
Select tube nominal internal diameter (ID):
AA = 1/4” (6.35 mm)
AB = 3/8” (9.53 mm)
AC = 1/2” (12.7 mm)
AD = 5/6” ( 7.9 mm)
Part Number Example: AC

STEP 2: Select baseplate length

survive the most rigorous of pressure tests.

Select length (L) specified in mm (user defined):

Embedding process

Maximum allowable length is 813 mm

The embedding process employed to manufacture
Aquasink allows you to mount electronic components
on both sides of the cooling plate with equal thermal
efficiency.

eg. L = 250 mm
Part Number Example: AC250

STEP 3: Select baseplate thickness
Select baseplate thickness (T) minimum 2x ID:
TA = 12.7 mm
TB = 19.1 mm
TC = 25.4 mm
TD = 15.9 mm
Part Number Example: AC250TC

STEP 4: Select baseplate width
Select baseplate width (W) specified in mm (user
defined): eg. W = 230 mm
Maximum allowable width is 610 mm
* Please refer to the numbered steps illustrated in this diagram.
Step numbers to the right correspond to the steps above.

Base materials
The heat collecting semi-conductor mounting surface
is fabricated from extruded 6063 aluminum alloy.
Commercial grade ASTM B-75 copper tubes of a size
to suit given applications are embedded within the
aluminum plate by a proprietary mechanical process
that provides an industry unique metal to metal bond
between the aluminum and copper. This process is
free of heat impeding glue or epoxy at the copper/
aluminum interface. The copper tube location can be
specified for practically any dimension from the datum

Part Number Example: AC250TC230

STEP 5: Select a finish
Choose from the following finishes:
D = Degrease Only
Part Number Example: AC250TC230D

STEP 6/7: Number of tubes/select
configuration
Select number of Tubes (user defined): eg. 6 tubes
Select tube configuration A,B,C,D,E or F
(visit website configuration details): eg. A
Part Number Example: AC250TC230D6A

point.

* Tube location and thermal modeling can be performed on R-Tools.

M18

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Liquid Cooled Aquamax

®

Copper Heatsinks

Superb thermal performance in copper
Aquamax® copper provides additional performance over aluminum using the same
proprietary channeling techniques as aluminum. The vacuum brazed, flux free
joint ensures leak and corrosion free construction. Typical external finish is RoHS
compliant electroless nickel.
Contact the Applications Department for Modeling Assistance
at 905-795-0077 x258 or x340.

Features/Benefits:
• Vacuum brazed copper construction
• Flux free
• Leak free
• Highest thermal performance
• Very rugged	

Performance:

Highlights:

Applications:

• Custom channels

• Any high power semiconductor

• Optimized channel design

• Contact factory applications
department

application

M

• No physical constraints

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M19

Liquid Cooled Aquasurf

®

Heatsinks

The lowest thermal resistance available
Copper tubes are embedded in the surface of an aluminum plate to provide the
lowest thermal resistance between the semiconductor mounting surface and the
cooling liquid. Tubes can be bent into complex arrays to ensure the copper surface
is directly under the semiconductor chips.
Contact the Applications Department for Modeling Assistance at 905-795-0077 x258
or x340.

Features/Benefits:
• 	 Aluminum body, copper tubes
• 	 Copper tubes embedded in aluminum surface
• 	 Copper tubes can be embedded both sides
• 	 Copper tubes can be custom formed to suit application
• 	 Epoxy interface between copper and aluminum
• 	 Lowest cost	

Performance:
• 	 Contact factory applications

Highlights:

Applications:

• 	 Custom tube layout

• 	 Any high power semiconductor

• 	Exposed copper tubes minimizes

department

application

thermal interface with
semiconductors
• 	 Parallel tube design option
equalizes junction temperatures

M20

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Liquid Cooled Aquamax

®

Aluminum Heatsinks

Maximum thermal performance in aluminum
Aquamax provides maximum thermal performance in aluminum by employing
proprietary channeling techniques to optimize coolant velocity at low head loss while
providing uniform temperature across the mounting surface. Precision machining
techniques used at the vacuum braze, flux free, interface ensure leak and corrosion
free construction. Typical external finish is RoHS compliant trivalent chrome.
Contact the Applications Department for Modeling Assistance at 905-795-0077 x258
or x340.

Features/Benefits:
• 	 Vacuum brazed aluminum construction
• 	 Flux free
• 	 Leak free
• 	 Low weight

Performance:

• 	 High thermal performance

• 	 Contact factory applications

• 	 Very rugged		

department

Highlights:

Applications:

• 	 Custom channels

• 	 Any high power semiconductor

• 	 Optimized channel design

application

M

• 	 No physical constraints

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M21

Press Pack Coolers
For demanding, high performance applications
Patented technology provides the highest performance vacuum brazed, flux free
Press Pack Coolers in both aluminum and copper construction.
Full specifications can be found on our website.

Features/Benefits:
• 	 Vacuum brazed construction
• 	 Aluminum or copper
• 	 Flux free
• 	 Leak free
• 	 Mixed metal adaptors
• 	 Highest thermal performance		

Highlights:

Applications:

• 	 Unique design

• 	 Any size press pack

• 	Cools all sizes of press pack

semiconductor

semiconductors

M22

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

Performance:
• 	 Contact factory applications
department

www.barr-thorp.com

Cooling Systems
The ultimate integrated cooling solution
To cool the hot fluid exiting a liquid cooled heatsink so that it may be recirculated
requires a liquid-to-air heat exchanger working in conjunction with pumps and
associated systems.
Full specifications can be found on our website.

Features/Benefits:
• 	 Cools recirculating liquids
• 	 Air cooled radiators
• 	 Copper or aluminum tubes
• 	 Copper or aluminum fins
• 	 Control apparatus
	

Highlights:

Applications:

Performance:

• 	 Compliments liquid cooled

• 	 Any liquid cooled recirculating

• 	 Contact factory applications

system

department

M

heatsinks

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M23

Product Materials & Tolerances
General materials

AQUASINK® and AQUASURF®

Baseplates: 	

Aluminum - 6063-T5, 6061-T6

Copper Tubes: 		

Commercial ASTM B-75

		

Copper - C11000

Inlet/Outlet Adapters: 	

Brass/Copper

Fins: 	 	

Aluminum - 6063-T5, 6061-T6, 1100-H14

Length (L) parallel to tubes:

		

Copper - C11000

			

≤ 305 mm ± 0.5 mm Aquasink-Max 813

Legs and Fan Bracket: 	 Aluminum 6063-T5

			

> 305 mm ± 1.0 mm

Tolerances: 	

Places 		

Value

			

No limit - Aquasurf

		

X 		

± 0.5 mm

Width (W) transverse to tubes: 		

		

XX 		

± 0.25 mm

			

Up to 610 mm ± 0.5 mm - Aquasink

		

XXX		

± 0.13 mm

			

No limit - Aquasurf

Angularity: 		

± 1/4°

Flatness (max.): 	

Machined (flycut) 0.03/25 mm

Note: Tighter tolerances can be supplied if required at some additional cost.

			

Unmachined 0.1/25 mm

Dimensions are in mm unless otherwise stated. Dual measurement convention mm

Surface Roughness (max.): 1.6 rms or better

(inches).

Locations of tubes from datum point: ± 1.0 mm

Drilled Hole Diameter: 	 ± .13mm

Fabfin (All fin spacings)
®

Nominal ID 	 6.35 (1/4) 	
OD* 	

7.93 (5/16) 	

9.53 (3/8)

8.07 ± 0.025 	 9.60 ± 0.025 	 11.50 ± 0.024 	

*after mandrel expansion process - Aquasink

Cut to Length: 	 < 305 mm ± 0.5

Finish-Copper Tubes: 	Natural

		

> 305 mm ± 1.0

Leak Testing: 		

Cut to Width: 	

± 0.5 mm

			contact factory.

Angularity: 	

Saw Cut ± 1/4°

		

Extrusion ± 1°

		

Machined ± 1/4°

Flatness (max.): Machined flycut 0.03/25 mm
Surface Roughness (max.): 1.6 rms or better
Overall Height: 	 ± 0.75 mm Fin height “H” ≤ 100mm
		

± 1.00 mm Fin height “H” > 100mm

Baseplate Thickness: ± 0.75 mm

Aquamax® (Copper or Aluminum)
Contact the factory for complete details at 905-795-0077

To 120 psi for 5 min.; other specs 		

Extrusion
The aluminum extrusions supplied by Mersen comply with the
standard commercial tolerances established by “The Aluminum
Association Inc.”, which roughly translate into the following
“rules of thumb” when applied to heatsink sections.

			

≤610mm ± 0.5mm
>610mm ≤ 1220mm ± 1.27mm

			

>1220mm ± 1.57mm

Cutting to Length: 	

Flatness (max. deviation): 0.1mm/25mm of width up to 250mm
			

0.2mm/25mm of width over 250 mm

Roughness/Die Lines: 	 Depth of defect <0.1mm
Angularity: 		

± 1°

Machined Parts

M24

Flatness (max. deviation): 	

0.03/25mm of width

Roughness: 	

1.6 rms or better

Angularity: 	

± 0.25°

Edge to Datum: 	

±0.25mm

Feature to Feature: 	

±0.13mm

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Product Materials & Tolerances
General finish type

Vibration

Meets the requirements of:

Fabfin’s durability of design has been independently

Black Anodize:

MIL-A-8625, Type II, Class 2, Black

tested, without failure, to the following parameters. All

Clear Anodize:

MIL-A-8625, Type II, Class 1, Clear

three axis tested, swept sine wave vibration resonance

Gold Chromate:

MIL-DTL-5541, Type I, Class 3, Gold

search from 5-200 Hz with a sweep rate of 0.5 oct./min.,

Trivalent Chromate:

MIL-DTL-5541, Type II, Class 3, Clear 

Electroless Nickel:

ASTM-B-733

Tin Plated Copper:

Lead Free

Tabs:

Lead Free

Wash:

Degrease Only

AQUASINK®/AQUASURF® - Degrease only
AQUAMAX® - COPPER - Electroless Nickel; degrease
AQUAMAX - ALUMINUM - Trivalent Chromate

at each resonant frequency, and a twelve hour durability
sweep from 5-200 Hz with 0.3 g input.

Welding
Welding baseplates together (after the addition of fins)
to increase overall width beyond 521 mm is common
practice since the fin to baseplate join is unaffected by the
welding process. If your finish selection is black anodize,
please note that a shade of black variance exists along
the weld joints.

Surface finish for Fabfin Anodizing

Temperature cycling

The entire family of Fabfin aluminum heatsinks can be

To determine the reliability of the metal displacement

anodized without worry of an inconsistent finish. Anodizing, by

swaging process both the FF & MF series Fabfin

its nature, requires that hundreds of amperes of DC current

assemblies were tested by an independent third party

be conducted through the entire heatsink body. Any resistance

laboratory. The results showed that extensive temperature

present in the interface (between the fin and the baseplate)

cycling, from -40°C to +120°C, and one time heating to

would cause the fins to appear “off black” or “grey” once the

+350°C, had no adverse effect on the performance of the

processing is complete. This is yet another test of the interface

heatsink.

between the fin and the baseplate which shows superior
performance over alternative assembly techniques. Clip marks

Fin pull tests

which show as white marks in a black anodize finish occur

A fin pull test was completed, following the temperature

where the electrical contact(s) is/are made. Clip marks can be

cycling period, on a 50 mm length of fin perpendicular

eliminated by inserting titanium screws into threaded holes in

to the baseplate, exceeded 900 kgs (18kg/mm) and

the heatsink to form the required electrical path. This process

occurred without failure of the fin to baseplate interface.

results in additional cost.

Surface “Finish Free”
“Finish Free” areas can be provided if required for electrical
conductivity.

MF & AF Fabfin
Specify blind holes wherever possible in the mounting

M

Tin Plated Solderable

Input acceleration amplitude of 0.5 g, A one hour dwell

surface. It should be recognized that some streaking
may occur at the plugged holes and as such cosmetic
requirements must be specified at time of RFQ.

Fabfin®
operating range

DF & FF Fabfin
Specify that through holes are acceptable in the

The swaging process which the entire family of Fabfin

mounting surface to eliminate the need to plug holes

heatsinks incorporates, allows all assemblies to successfully

when finishing. It should be recognized that deburring

pass the harshest environmental and physical tests. Storage

between the fins may leave minor scratches near the

and operating temperatures of -40°C to +350°C demonstrate

through holes and as such cosmetic requirements must

that Fabfin heatsinks are unmatched by other less robust

be specified at time of RFQ.

methods of construction.

For more product information visit us-ferrazshawmut.mersen.com > Products > Product Data > Thermal Management.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M25

R-Tools® 3D Heatsink Modeling
Powerful thermal modeling software
Mersen makes it easy and convenient to quickly and accurately model
various heatsink configurations using the R-Tools online thermal modeling
software program. R-Tools is completely interactive. It uses analytically
based design tools allowing you to perform the thermal design of the heatsink
concurrent with the optimization of the electrical and manufacturing elements
prior to any prototype builds and testing. This invaluable resource reduces
your design time and increases the reliability in your finished product.

Features/Benefits:
• 	 Completely interactive on-line thermal design tool for heatsinks.
• 	 Quick and accurate heatsink solutions.
• 	 Analytical models for conduction heat transfer in the solid elements.
• 	 Natural and forced convection heat transfer models in the cooling airflow.
• 	 Reduction in design time and better reliability in the finished product.
• 	 User-friendly approach introduces users to R- Tools.
• 	 Colorful and clear graphics.
• 	Design tips and notes.
• 	 Step by step approach.
• 	Liquid and air-cooled heatsinks.

Need more support?
Mersen is a company that is easy
to do business with. Our leading
engineers will work with you to
develop tailored solutions for
removing damaging heat from your
electronic systems.

• 	 Graphical source layout.
• 	 Parts library for semi-conductors, thermal interfaces, and fans.
• 	 Fin optimizer solves for optimum heatsink configurations.
• 	 Thermal design output details heatsink performance.
• 	 Heatsink thermal map shows temperature profile of the heatsink baseplate.
• 	Hydraulic performance chart displays heatsink vs. fan performance curves.
Visit R-Tools under Resources at www.us-ferrazshawmut.mersen.com.
Email: 		
sales.mis@mersen.com
Manufacturing: 	
905-795-0077
Applications support: 	
905-795-0077 x258 or x340

M26

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

R-Tools® 3D Heatsink Modeling
Powerful 3D thermal modeling software
Heatsinks are used with semi-conductor devices to provide

User Option Menu gives the user two
options for using R-Tools:

more surface area for heat dissipation. Power electronic

i) Step by step option is the default option for all new

designers require quick and accurate heat sink solutions.

users. This user-friendly approach introduces users

With the advent of the internet, and realizing the potential of

to the R-Tools concept of designing heatsinks on-line.

providing interactive design capability on the Web, Mersen

Colorful and clear sketches are used to describe the

offers R-Tools; a completely interactive on-line thermal

basic dimensions and parameters of the heatsink

design tool for heatsinks. The R-Tools mathematical engine is

design. When the user points the cursor in any text

located on a web server at us.ferrazshawmut.com/thermal/r-

box, design tips and notes are displayed in green

tools_front.cfm. R-Tools simulation can be run on an Internet
browser, which is capable of utilizing Java Applets. R-Tools

color at the bottom of the screen.
ii) For advanced users the Compact Pages option

thermal modeling is based on a set of analytical models for

reduces the design screens down to four screens,

conduction heat transfer in the solid elements coupled with

which reduces the design and browsing time.

natural and forced convection heat transfer models in the
cooling airflow. The conduction heat transfer model in the
baseplate of the heatsink is based on the steady state solution
of the Laplace equation for general rectangular geometry. The

File Menu allow users to copy, rename
and delete existing simulations.
On simulation screens, the left-hand side menu list the

solution is based on a general three-dimensional Fourier series

steps of navigating R-Tools through the designing of

solution, which satisfies the conduction equation in the base

Mersen

plate. For the forced convection air-cooled fins, an analytical

heatsinks. Users have two options to navigate through

model is used to predict the average heat transfer rate. The

R-Tools screens as follows:

model used is a composite solution based on the limiting cases

a) Navigate step by step through any R-Tools screen

of fully developed and developing flow between parallel plates.

by clicking the “Next” button on the bottom of each

Because the R-Tools is analytically based, the solution is

screen.

achieved within a few seconds, a very short time compared to

b) Display the desired R-Tools screen by clicking on the

the several hours required for a full CFD simulation.

screen name on the left-hand side menu.

R-Tools provides an analytical method for quickly and

On the Web:

accurately testing various heat sink configurations. The use of
analytically based design tools allows the user to perform the

Visit R-Tools under Resources on our website.

thermal design of the heatsink concurrent with the optimization
of the electrical and manufacturing elements prior to any

M

prototype or testing. This approach results in a reduction in
design time and better reliability in the finished product.

Free on-line registration
Users may register for R-Tools by visiting our website Selecting
Resources > R-Tools. On the first screen of R-Tools, a menu
on the left-hand side of the screen lists selections and options
available for users such as: Simulation Menu button allows the
user to start a new simulation.

For more product information visit us-ferrazshawmut.mersen.com > Products > Product Data > Thermal Management.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M27

R-Tools® 10 Easy Steps
STEP 1: Starting simulation
To start a simulation on R-Tools, there are three options:
• “Create New Simulation” by typing a simulation name and
selecting the product which is suitable for the applications:
Examples: Extrusion, Fabfin, Aquasink.
• “Simulation Based on Known Part Number” by typing in a
simulation name and the appropriate Mersen part number to
generate a new simulation: Example: FF300T13A30AC118B.
• “Open Existing Simulation” by selecting the name of the simulation
from the drop down list of your previously created simulations.
Note: Click the next button to go to the next screen, baseplate
dimensions.

STEP 2: Baseplate dimensions
• The sketch on the right hand side of the screen demonstrates the
three dimensions of the baseplate.
• Enter the dimensions by typing in the value (mm or inches) in the
corresponding text box.
• The user can select a standard thickness or customized one by
typing the value in the text box.
• The green design on the bottom right side of the screen will inform
the user about Mersen manufacturing capabilities.

STEP 3: Environmental conditions
• “Ambient Temperature” is the temperature of the air cooling the
heatsink. “Ambient Temperature” can be entered in ºC or ºF.
• “Altitude” of the application can effect the cooling capacity of the
heatsink because it can change density of the cooling air.
Note: The name of the simulation will always appear on the top of the screen.

M28

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

R-Tools® 10 Easy Steps
STEP 4: Flow conditions
The heatsink can be cooled using one of the heat transfer modes:
• “Natural Convection” mode where air moves through the
heatsink due to the buoyancy effects.
•• Forced convection mode which has two input options in
R-Tools.
1.	 “Specific Air Flow”: The user has to enter the appropriate
volumetric flow rate of the air cooling the heatsink, or
2.	 “Fan From Library”: The user can select a fan from the drop
down list.
• For forced convection the user can select the flow direction:
1. Push, or
2. Impinging, or
3. Push/Pull.
Note: By-pass air is not modeled in R-Tools. All air flow data entered is assumed to be
presented to the face of the heatsink.

STEP 5: Graphical source layout
A sketch of the main dimensions of the heatsink and the locations
of the heat source is shown at the bottom of the screen. To add a
heat source on the baseplate of the heatsink, click “Add” button.
R-Tools allows two options for specifying the heat source: i.e.
component:
1. Customize the specifications of the device by entering the
dimensions, power dissipation and the thermal resistance,
Rjc of the device in the corresponding text boxes on the
screen.
2. Select an industry standard semiconductor from the dropdown list.
• Users can change the dimensions (W, H) and the location
(X1, Y1) of any source on the heatsink graphically or by

M

typing the values in the corresponding text box.
• To rotate the source on the heatsink, click “Rotate” button.
• To delete a source, click on the “Delete” button.

STEP 6: Thermal interface material
Users can enter the thermal impedance, Rimp, of the interface
material by:
• Typing its value in the textbox, or
• Selecting the manufacturer and the part number of the interface
from the drop down lists.

STEP 7: Save
At this point, you must click “SAVE” before advancing to the “Next”
screen!

For more product information visit us-ferrazshawmut.mersen.com > Products > Product Data > Thermal Management.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M29

R-Tools® 10 Easy Steps
STEP 8: Fin selection and optimizer
Users can select from the two following options:
1. Fin optimizer: the user must enter
a) Thermal constraints i.e. Maximum Temperature allowed on the heatsink.
b) Physical constraints i.e. Maximum Height allowed for the heatsink.
• The fin optimizer will solve all fin configurations, which will meet the thermal
performance i.e. maximum allowed temperature, and will list all the
available
selections in the “Fin Optimizer Results” table.
• Click on any header of the “Fin Optimizer Results” table to sort the table
according to the header name ie: the user can sort the table by the mass of
the heatsink by clicking on the “Mass” header.
• When selecting any configuration from the table a green design note will
describe the main specification of the selected fin.
2. User defined fin selection:
For users familiar with the Mersen Fabfin® heatsink configuration, “User
Defined Fin Selection” allows users to select the exact Mersen standard fin
design as follows:
• MF is the recommended fin design for forced convection applications with
maximum height of 49 mm.
• AF is recommended for forced convection applications, which require low
pressure drop i.e. low noise levels.
• DF has three fin designs satisfying different application objectives as
follows:
i) Serrated Fin: for high power dissipation.
ii) Corrugated Fin: for weight sensitive applications.
iii) Hollowfin: for high power dissipation applications. Hollowfin with the
advantage of lower pressure drop performance and lower weight.
• FF is a suitable selection for natural convection heat transfer. FF can be
used for relatively low power dissipation forced convection applications. FF
has two fin designs as follows:
i) Serrated Fin: provides mechanical integrity.
ii) Corrugated Fin: larger surface area to provide better cooling for
natural convection.
Note: Fin height can be customized by the user with certain limitations for each group: MF: minimum of
25 mm and maximum of 49 mm; AF, DC, FF: minimum of 25 mm and maximum of 118 mm. Hollowfin is
recommended as an alternative to a MF fin when a fin height higher than 49 mm is needed to dissipate more heat.

STEP 9: Miscellaneous factors:

On this page users can define the following:
	i) “Thermal Plot Size” in the final simulation i.e. for large heatsinks it is better to reduce the display to 50% or 25% of
the original size so that the display will appear inside the web page.
	ii) Specify the “Finish” of the final product which can be one of the following:
		• Degreased;
• Black anodized (recommended for natural convection;)
• Clear anodized;
• RoHS compliant clear tri-valent chrome.
	iii) Mounting option where the user can select to attach legs for the heatsink for mounting.
Click “Simulate” for the full thermal simulation for Mersen heatsink.

M30

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

R-Tools® 10 Easy Steps
STEP 10: R-Tools simulation-design output summary
The summary contains three main sections
A) Numerical results summary (contains three sections)
1. Heatsink Design Details Section: The physical dimensions of the heatsink
such as weight, fin height, fin spacing, baseplate thickness, fin material,
baseplate material etc. It also generates a Mersen part number.
2. Thermal Design Detail Section: A full list of the heat sources is displayed.
For each source the the following information is displayed:
• W & L: foot print of the heat source i.e. device;
• Power: heat dissipation;
• Tsavg: average temperature of the baseplate under the device;
• Tcase: average case temperature;
• Tjunction: average junction temperature;
• Fin Efficiency;
• Thermal Resistances associated with each device.
3. Hydraulic Design Details Section: This section displays three main
sub-sections:
a) Coolant Information (if applicable):
•	 Coolant type air, water, Water/Glycol mix etc.;
•	 S
 upply: shows the fan name, number of fans used in the application
and cooling style;
•	 Inlet and the outlet coolant temperatures (air or liquid);
b) Pressure drop through the entrance, the heatsink core, and exit section.
The sum of the pressure drop through the three sections is displayed under
total header.
c) Reynolds number, which is a measure of the turbulence level in the fluid
flow.
B) Heatsink thermal map:

M

This shows a temperature profile of the heatsink baseplate. Hot spots on the
heatsink baseplate are identified by the red color in the thermal map. The
maximum temperature under each device is printed on the thermal map in the
square which identifies the location of each device.
C) Hydraulic performance chart (fan should be selected):
This displays heatsink performance curve vs. fan performance hydraulic curve.
Displaying the performance point of the system helps designers to determine the
noise level and fan efficiency. A second degree equation which represents the heatsink
performance curve can help designers include the designed heatsink in CFD models.

For more product information visit us-ferrazshawmut.mersen.com > Products > Product Data > Thermal Management.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

M31

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Surge Protection
Fail-safe overvoltage protection in a full range of options

Your problem:
Power-related
problems cost
U.S. companies
more than $80

N

Surge Protection

• Surge-Trap® Modular SPD................ N2

billion dollars

• Surge-Trap® Pluggable SPD............. N4

a year. Most

• Surge-Trap® Type 1 T2 Series .......... N6

transients
originate from
within a facility

• Surge-Trap® Type 1 XR Series.......... N8
• Surge-Trap® Type 1 XP Series ....... N10

and nearly 80% of today’s overvoltage problems are caused by

• Surge-Trap® Type 1 XT Series ....... N12

equipment and power disturbances within the plant. These inner-

• TPMOV® Technology....................... N14

facility transients are caused, for example, by light load panels
switching on and off, motors starting and stopping, and close
conductor proximity. Less than 20% of the transient problems

• VSP MOV Fuses............................. N16
• Surge Switch................................... N18

originate outside the facility due to lightning strikes, utility grid
switching, switching capacitor banks, and electrical accidents.
Our solution: You need fail-safe surge suppression, and the
reliability and cost savings of Mersen’s Surge-Trap® Surge
Protection Devices with patented TPMOV® Technology inside.
Surge-Trap SPDs provide a compact, space saving solution.
Plus, unlike other SPDs on the market, they do not require
additional overcurrent protection, thus offering reduced
installation costs.
Want more information fast? For more technical or applicationspecific information, please call our overvoltage protection

N

experts, at 978-462-6662; 416-252-9371 in Canada; or visit our
website at us-ferrazshawmut.mersen.com.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Surge-Trap® Modular SPD
DIN-rail Style SPD
Surge-Trap® Modular Surge Protective Device (SPD) is a no-fuse, fail-safe surge
suppressor featuring Mersen’s patented TPMOV® technology inside. The modular
SPD is UL 1449 Third Edition approved. It is DIN-rail mountable featuring a fail-safe
self-protected design, visual indicator and a small footprint. A remote indicator option
provides status to critical control circuitry. The Surge-Trap Modular SPD has a high
short circuit rating and a thermally protected MOV, which eliminates the need for
additional overcurrent protection devices.

Features/Benefits

Applications:

•• Easy installation or retrofit

•• AC/DC distribution

•• DIN-rail mountable

•• Power supplies

•• Fail-safe, self-protected design

•• Industrial automation

•• Remote indicator (optional)

•• Telecommunications

•• Visual indicator

•• Motor controls and starter systems

•• IP20 finger-safe design

•• Programmable logic controller
(PLC) applications

•• Small footprint
•• No additional overcurrent
protection devices required

•• Power transfer equipment
•• HVAC applications
•• AC drives
•• UPS systems
•• Security systems
•• IT/Data centers
•• Medical equipment

Ratings:
Volts	

: 120V to 600V

			

: 600V to 1000V (PV only)

SCCR 	 : 200kA
Operating & storage temp
		

: -250C to +600C

Wiring range:
		

: #6 to #14AWG

Nominal discharge current
		

: 20kA

Dimensions
Approvals:
•• UL 1449 Third Edition Approved,
File E210793
•• Type 4 UL Recognized
Component (Tested to UL Type
2 SPD)
•• IEC 61643-1
•• RoHS Compliant
•• ANSI/IEEE C62.41
•• CE

N2

Poles

A

1 Pole

17.8 mm

2 Pole

35.5 mm

3 Pole

53.3 mm

4 Pole

71.0 mm

** Wire Size: 6-14 AWG
** Torque: 15 lbs-in
** Use 35mm DIN-rail

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Surge-Trap® Modular SPD
Product Type
ST
ST- Modular

Voltage
480
120
120/208
120/240
240
277
347
480
240/480
277/480
347/600
600
1000

Catalog Numbers

System Type
3PY
1P - Single Phase
SP - Split Phase
3PD - 3 Phase Delta

Mode
G
Blank - Includes N-G Mode
G - Does Not Provide N-G Mode

3PY - 3 Phase Wye
PV - Photovoltaic

Indicates PV only

Nominal
Voltage
(VAC)

MCOV
L-G

No. of
Poles

System
Type

Nominal
Discharge
Current
** (In, kA)

Max. Discharge
Current
SCCR
(Imax, 8/20µs,
(kA)
kA)

Freq
(Hz)

ST1201PGM

120

180

1

1P

20

50

200

ST2301PGM

240

270

1

1P

20

50

ST2771PGM

277

320

1

1P

20

ST2083PYM

120/208

360

4

3PY

ST2083PYGM

120/208

180

3

ST240SPGM

120/240

180

ST480SPGM

240/480

ST2403PDGM

Catalog
No.

Auxiliary Microswitch
M
Blank - No Microswitch
M - Microswitch Included

Voltage Protection Rating
(VPR)

No. of
Wires

Circuit
Connection
Wiring
Diagrams

L-N

L-G

N-G

L-L

50/60

500

-

-

-

2

A

200

50/60

800

-

-

-

2

A

50

200

50/60

900

-

-

-

2

A

20

50

200

50/60

500

900

500

900

5

D

3PY

20

50

200

50/60

500

-

900

4

C

2

SP

20

50

200

50/60

500

-

900

3

B

270

2

SP

20

50

200

50/60

800

-

-

1500

3

B

240D

270

3

3PD

20

50

200

50/60

-

800

-

1500

4

C

ST4803PYM

277/480

500

4

3PY

20

50

200

50/60

1000

1500

500

1800

5

D

ST4803PYGM

277/480

320

3

3PY

20

50

200

50/60

900

-

-

1800

4

C

ST4803PDGM

480D

550

3

3D

20

50

200

50/60

-

1500

-

3000

4

C

ST6003PYM

347/600

690

4

3PY

20

50

200

50/60

1500

2500

800

2500

5

D

ST6003PYGM

347/600

420

3

3PY

20

50

200

50/60

1200

-

-

2000

4

C

Catalog
No. PV

Nominal
Operating DC
Voltage (V)

Ucpv*

Nominal
Discharge
Current
(In,8/20, kA)

Imax Discharge
Current
(Imax, 8/20µs, kA)

Voltage
Protection
Level (Up @
In, kV)

Iscwpv**
L/R
(kA)

Replacement
Plug Part No

No.
Wiring
of
Diagrams
Poles

ST600PVM

600

720

10

40

<2.4

10

<= 1mS

-

2

E

ST1000PVM

1000

1200

10

40

<4.0

10

<= 1mS

-

3

F

	

A

B

	

C

D 		

E		

F
L+

L2

G

L-

N

* Ucpv: Maximum continuous operating DC voltage. **Values based upon SPD type 2 testing		

G

G/N

G/N

G

G/N

L

L1
N

N
G

Single Phase
2 Wire + Ground

L2
G

Split Phase
3 Wire + Ground

L1

L1

L2
N

L2
L3
G

3 Phase Delta
3 Wire + Ground

L3
G

3 Phase Wye
4 Wire + Ground

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

N3

Surge-Trap® Pluggable SPD
DIN-rail Style SPD
Surge-Trap® Pluggable Surge Protective Device (SPD) is a no-fuse, fail-safe surge
suppressor featuring Mersen’s patented TPMOV® technology inside. The pluggable
SPD is UL 1449 Third Edition approved. It is DIN-rail mountable featuring a fail-safe
self-protected design, visual indicator and a small footprint. A remote indicator option
provides status to critical control circuits. The Surge-Trap Pluggable SPD has a high
short circuit rating and a thermally protected MOV, which eliminates the need for
additional overcurrent protection devices.

Features/Benefits:

Applications:

•• Easy installation or retrofit

•• AC/DC distribution

•• DIN-rail mountable

•• Power supplies

•• Fail-safe, self-protected design

•• Industrial automation

•• Remote indicator

•• Telecommunications

•• Visual indicator

•• Motor controls and starter
systems

•• IP20 finger-safe design

•• Programmable logic controller

•• Small footprint

(PLC)

•• No additional overcurrent

•• Power transfer equipment

protection devices required
•• Easy to replace modules

•• Photovoltaic systems

•• Two-year warranty

•• HVAC applications

Ratings
Volts	: 120V to 600V
			

: 600V to 1000V (PV only)

SCCR 	 : 200kA
Operating & storage temp
			

: -250C to +600C

Wiring range:

•• AC drives

			

•• UPS systems

: #6 to #14AWG

Nominal discharge current

•• Security systems

		

•• IT/Data centers

: 20kA

•• Medical equipment

Dimensions
.8
8.

Poles
.
8.
.
1 .2

.7
17.8

A

1 Pole

18.03 mm

2 Pole

36.06 mm

3 Pole

54.10 mm

4 Pole

72.13 mm

Approvals:
•• UL 1449 Third Edition Approved,
File E210793
•• Type 4 UL Recognized
Component (Tested to UL Type
2 SPD)
•• IEC 61643-1
•• RoHS Compliant
•• ANSI/IEEE C62.41
•• CE

.1
.

2.82
71.8

2.
.7

.
11.1

N4

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Surge-Trap® Pluggable SPD
Product Type
STP
STP - Pluggable

Voltage
480
120
120/208
120/240
240
277
347
480
240/480
277/480
347/600
600
1000

Catalog Numbers

System Type
3PY
1P - Single Phase
SP - Split Phase
3PD - 3 Phase Delta
3PH - 3 Phase Highleg
3PY - 3 Phase Wye
PV - Photovoltaic

Mode
G
Blank - Includes N-G Mode
G - Does Not Provide N-G Mode

Auxiliary Microswitch
M
M - Microswitch Included

Indicates PV only

Catalog
No.

Nominal
MCOV No. of
Voltage
L-G
Poles
(VAC)

Nominal
System Discharge
Type
Current
** (In, kA)

Max.
Discharge
Current
(Imax,
8/20µs, kA)

SCCR Freq
(kA)
(Hz)

Voltage Protection Rating
Replace(VPR)
No. of
ment Plug
Wires
Part No
L-N
L-G N-G L-L

Circuit
Connection
Wiring
Diagrams

STP1201PGM

120

180

1

1P

20

50

200

50/60

SP180U

600

STP2083PYM

120/208

360

4

3PY

20

50

200

50/60

SP180U

600

STP2083PYGM

120/208

180

3

3PY

20

50

200

50/60

SP180U

600

STP2301PGM

240

275

1

1P

20

50

200

50/60

SP275U

900

STP2403PDGM

240D

275

3

3PD

20

50

200

50/60

SP275U
600

600

900

2

A

1200

5

D

1200

4

C

2

A

1800

4

C

1200

5

E

1200

50

200

50/60

SP180U,
SP275U

20

50

200

50/60

SP180U

600

3

B

20

50

200

50/60

SP320U

1000

2

A

1P

10

50

200

50/60

SP420U

1500

2

A

3PD

10

50

200

50/60

SP550U

3000

4

C

STP2403PHM

120/240

*

4

3PH

20

STP240SPGM

120/240

180

2

SP

STP2771PGM

277

320

1

1P

STP3471PGM

347

420

1

STP4803PDGM

480D

550

3

SP275U,
SP550U,
SP180U
SP320U,
SP180U

240/480

*

4

3PH

10

50

200

50/60

STP4803PYM

277/480

500

4

3PY

20

50

200

50/60

STP4803PYGM

277/480

320

3

3PY

20

50

200

50/60

SP320U

1000

STP480SPGM

240/480

275

2

SP

20

50

200

50/60

SP275U

900
1500
1500

STP6003PYM

347/600

695

4

3PY

10

50

200

50/60

SP420U,
SP275U

STP6003PYGM

347/600

420

3

3PY

10

50

200

50/60

SP420U

Nominal
Nominal
Discharge
Operating DC Ucpv*
Current
Voltage (V)
(In,8/20, kA)

1200

600

1800

STP4803PHM

Catalog
No. PV

1200

900

1500

600

1800

5

E

1000

1500

600

1800

5

D

1800

4

C

1800

3

B

2500

5

D

2500

4

C

No. of
Poles

Wiring
Diagrams

Voltage
Imax Discharge
Iscwpv**
Protection Level
Current
(kA)
(Imax, 8/20µs, kA) (Up @ In, kV)

2000

900

Replacement
Plug Part No

L/R

STP600PVM

600

720

10

40

<4.0

10

<= 1mS

SP670PV

2

F

STP600YPVM

600

720

20

40

<4.0

10

<= 1mS

SP350PV

3

G

STP1000YPVM

1000

1200

10

40

<4.0

10

<= 1mS

SP560PV

3

G

STP1200YPVM

1200

1440

10

40

<4.0

10

<= 1mS

SP560PV

3

G

A

B

C

D

E

L+

G

L1
N

N
G

Single Phase
2 Wire + Ground

L-

G

G/N

L

G

G

G/N

G/N

G

F

L2 High Leg

L2

N

* Ucpv: Maximum continuous operating DC voltage. **Values based upon SPD type 2 testing			

L2
G

Split Phase
3 Wire + Ground

L1

L1
L2
L3
G

3 Phase Delta
3 Wire + Ground

L2
N
L3
G

3 Phase Wye
4 Wire + Ground

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

N5

Surge-Trap® Type 1 SPD
UL TYPE 1 SPD for Indoor Applications
The Surge-Trap® Type 1 SPD meets requirements for UL 1449 Third Edition and is
ideal for indoor applications. It provides a two-year warranty and offers an economical
replacement for the former surge arrestor category. The Surge-Trap Type 1 SPD
features TPMOV® technology inside making it a “no-fuse” surge suppressor that
doesn’t require the use of additional overcurrent protection. It can be installed
upstream or downstream of the main disconnect.

Features/Benefits:

Applications:

•• Compact design

•• AC distribution

•• Panel mount

•• Power supplies

•• No additional overcurrent

•• Industrial

protection devices required

•• Commercial

•• 200kA Short circuit current rating

•• Telecommunications

(SCCR)

•• Residential

•• UL 1449 Third Edition Type 1 listed

Ratings:

•• IT / Data centers

Volts	

•• For indoor, NEMA 2, applications

: 120V to 600V

SCCR 	 : 200kA

•• Status LEDs

Operating & storage temp

•• Two-year warranty

			

: -250C to +600C

Wiring size
			

Dimensions

		

2.370

3.750

3.700

2.370

: 16” #12 AWG integral 	
leads

Enclosure
	

: NEMA 2x

Nominal discharge current
4.725

4.050

3.702

		

3.002

: 20kA

Approvals:
Single / Split Phase

Three Phase
7

6

5

4

2

3
REV.

DESCRIPTION

1
DATE

File E210793
•• Type 1 Listed for United States

APPROVED

Installation Diagram

•• UL 1449 Third Edition Approved,

D

•• Type 2 Listed for Canada
•• RoHS Compliant
•• ANSI/IEEE C62.41
•• CE

C

NUT

B

A

7

N6

6

5

4

3

2

1

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Surge-Trap® Type 1 SPD
Catalog Numbers
Nominal

Catalog

Voltage

No.

(VAC)

Nominal
System

Freq

MCOV

Discharge

Type

(Hz)

(L-G)

Current

Voltage Protection Rating (VPR)
UL Listing Type

(In, kA)

L-N

L-G

N-G

L-L

Circuit Connection
Wiring Diagrams

STT21201PG

120

1

50/60

180

20

700

1200

600

-

USL - Type 1

A

STT2240SPG

120/240

1S

50/60

180

20

700

-

-

1200

USL - Type 1

B

STT22083PYG

120/208

3Y

50/60

180

20

700

-

-

1200

USL - Type 1

D

STT24803PYG

277/480

3Y

50/60

320

10

1200

-

-

2000

USL - Type 1

D

STT26003PYG

347/600

3Y

50/60

420

10

1500

-

-

2500

USL - Type 1

D

STT22403PDG

240

3D

50/60

270

20

-

1000

-

1800

USL - Type 1

C

STT24803PDG

480

3D

50/60

550

10

-

1800

-

3000

USL - Type 1

C

Single/Split Phase
B

A

Three Phase Delta & Wye
C

D

N

Note: Must be installed
on a solidly grounded
system.

L

L1
N

N
G

Single Phase
2 Wire + Ground

L2
G

Split Phase
3 Wire + Ground

L1

L1

L2
N

L2
L3
G

3 Phase Delta
3 Wire + Ground

L3
G

3 Phase Wye
4 Wire

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

N7

Surge-Trap® Type 1 XR Series SPD
The Surge-Trap® Type 1 XR Series meets requirements for UL1449 Third Edition and
is ideal for the replacement of obsolete surge arrestors. The XR Series SPD feature
TPMOV® technology inside making them the safest product available. With a small,
compact design and line or load installation flexibility the XR series is the perfect fit
from service entrance all the way down to a specific control panel.

Features/Highlights:
•• UL 1449 Third Edition Listed,Type
1 SPD
•• Can be installed line-side or loadside of main disconnect
•• 20kA Nominal discharge current
•• 200kA SCCR (most models)
•• UL 96A Lightning Protection
Master Label compliant (20kA, In)
•• Large block 50kA Thermally
Protected MOVs
•• Pre-wired with 3’ (1m) of #10 AWG
conductor
•• Standard NEMA 4X polycarbonate
enclosure

Applications:
•• AC Distribution
•• Power supplies
•• Drive Protection
•• Fire Alarms
•• Control Panels
•• Telecommunications
•• Residential
•• IT / Data centers

Mounting:
•• STD 3/4” -14 nipple
•• DIN-rail mount
•• Bracket mount (flat surface)

•• Tri-mount installation kit Included
(pipe nipple, bracket, DIN-rail)
•• Two-year warranty

Ratings:
Surge	 : 50kA per phase
Volts	: 120V to 600V
SCCR 	 : 200kA (most models)
Nominal discharge current
		

: 20kA rating 8x20µs pulse

Operating & storage temp
		

: -250C to +600C

Enclosure
	

: NEMA 4X

Green=Go Visual
Diagnostic Monitoring
•• Green LED = A-OK, Out = replace
•• Visible from multiple sides &
angles for better viewing
•• Every MOV is monitored as
opposed to ‘power is present’

Dimensions & Weight

Approvals:
•• UL 1449 Third Edition File
VZCA.E210793
•• IEC 61643
•• CE
•• ANSI/IEEE C62.41
•• Burn-In tested prior to shipment
•• UL 96A lighting protection
master label

N8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Surge-Trap® Type 1 XR Series SPD
Catalog - Ordering System
STXR Series

STXR

System

Surge

System Config

Voltage

Rating

Options

120V

1P = One Pole, Single Phase

Blank

127V

2P = Two Pole, Split Phase

N = Neutral to Ground Protection on 50kA units

220V

3Y = Three Pole Wye

D = Dry Contacts and Audible Alarm

240V

3D = Three Pole Delta

277V

3H = Three Pole Hi-Leg

F = Neutral and Ground modes reversed

50

P = LED and / or Diagnostics

347V

R = Removes all Diagnostics

480V

M = Provides TPMOV microswiches for use

600V

8 = Replace 10AWG with 8AWG leads

* Please call factory

Example STXR4803DS50D
STXR

for specific product

480V

3D

50

D

performance data.

Wiring Diagrams
Figure 2

}V
}V

Hot (BLK)

Phase A (BLK)
B Phase B (BLK)

A

Neutral (WHT)
Hot (BLK)
Ground (GRN)

SPLIT
2 Hots, 1 Neu, 1 Grnd

N

C

}

Phase A (BLK)
Phase B (ORNG)

}

V

Phase C (BLK)

Ground (GRN)

HI-LEG DELTA (B High)
3 Hots, (B HIGH),
1 Neu, 1 Grnd

Figure 5

}

Phase A (BLK)

Figure 6

}V

Hot (BLK)

V

Phase B (BLK)
Phase C (BLK)

Neutral (WHT)
Ground (GRN)

Phase C (BLK)

WYE
3 Hots, 1 Neu, 1 Grnd

}

V

Neutral (WHT)
V

Figure 4

Figure 3

Neutral (WHT)

Phase A (BLK)
Phase C (BLK)
Ground (GRN)

Ground (GRN)

Ground (GRN)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

DELTA & HRG WYE
3 Hots, 1 Grnd

Optional Form C Dry Contact and Audible Alarm
Form C Dry Contact
Three (3) #18 wires exit the pipe nipple
Gray is common, blue is normally open, Red is normally closed.
•	 Normally open: Use gray & blue
•	 Normally closed: Use gray & red

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd
Dry
Contact
Leads

Power
Leads

Audible Alarm
Alarm sounds when any protection is lost (If diagnostic LED extinguishes (i.e. problem), alarm will sound)

Red
Blue

Catalog No.

System Voltage &
Config.

STXR120V1P50
STXR120V2P50
STXR120V3Y50
STXR127V1P50
STXR127V2P50
STXR127V3Y50
STXR220V1P50
STXR220V3Y50
STXR240V3H50
STXR240V1P50
STXR240V3D50
STXR277V1P50
STXR277V2P50
STXR277V3Y50
STXR347V3Y50
STXR480V1P50
STXR480V3D50
STXR480V3H50
STXR600V3D50

120V
120V/240V
208Y/120V
127V
127/254V
220Y/127V
220V-1 pole
380Y/220V
120/240V - Hi-Leg Delta
240V-1 pole
240V Delta 277V
240/480V
480Y/277V
600Y/347Y
480V-1 pole
480V Delta - 3 Pole
240/480V -Hi-Leg Delta
600V Delta - 3 Pole

Gray

UL 1449 Third Edition (Sept 2009) Voltage Protection
L-N
600
600
600
700
700
700
1200
1200
600/1200
1200
1200
1200
1200
1500
1800
1200/1800

Rating VPR 3000A
L-L
N-G*
600*
1000
600*
1000
600*
600*
1200
600*
1200
600*
1000*
2000
1000*
1000/1500
600
1000
1500
1000*
2000
1000*
2000
1000*
2500
1200*
3000
2500
2500

L-G*
1000*
1000*
1000*
1200*
1200*
1200*
1800*
1800*
1000/1500
1800
1200
1800*
1800*
1800*
2500*
1800
2500

In
20kA
20kA
20kA
20kA
20kA
20kA
20kA
20kA
20kA
20kA
20kA
20kA
20kA
20kA
20kA
10kA
10kA
10kA
20kA

SCCR
200kA
200kA
200kA
100kA
100kA
100kA
200kA
200kA
200kA
200kA
200kA
200kA
200kA
200kA
200kA
200kA
200kA
200kA
200kA

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

MCOV
150
150
150
180
180
180
320
320
150/320
320
321
320
320
320
420
550
550
320/550
690

N

Figure 1

N9

Surge-Trap® Type 1 XP Series SPD
The Surge-Trap® Type 1 XP Series offers advanced performance over other products.
The XP meets requirements for UL1449 Third Edition and has been designed to be
as compact as possible while offering advanced protection. The XP features TPMOV®
technology inside making it the safest product available. Installation can be done on
the line or load side of a panel. The XP is the perfect fit from service entrance all the
way down to an important machine specific control panel.

Features/Highlights:

Applications:

•• UL 1449 Third Edition Listed,

•• AC Distribution

Type 1 SPD (Sept. 2009)

•• Power supplies

•• Can be installed line-side or

•• Drive Protection

load-side of main disconnect

•• Fire Alarms

•• 20kA Nominal discharge current

•• Control Panels

•• 200kA SCCRs (most models)

•• Telecommunications

•• UL 96A Lightning Protection

•• Residential

Master Label compliant

•• IT / Data centers

Ratings:
Surge	 : 100kA

(@20kA In)

			

•• Pre-wired with 3’ (1m) of #10

Phase L-N

				

AWG conductor

L-G

N-G

50kA 50kA 50kA

Volts	: 120 - 600

•• Voltage specific design –

SCCR 	 : 200kA (most models)

highly configurable

Nominal discharge current	

•• All MOV suppression elements

		

monitored

: 20kA (most models)

•• NEMA 4X enclosure

Operating & storage temp

•• Ten-year warranty

		

•• Phase-loss monitoring (toggles

Enclosure
	

LED and dry contacts)

Dimensions and Weight

: -250C to +600C
: NEMA 4x

Approvals:
•• UL 1449 Third Edition, (cUL
Type 2 optional)
Weight: 3lbs (1.4kg)

•• UL File VZCA.E210793
•• RoHS Compliant
•• IEC 61643, CE
•• Burn-In tested prior to shipment
•• UL 96A lighting protection
master label

N10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Surge-Trap® Type 1 XP Series SPD
Catalog - Ordering System
STXP

System Voltage

S

Surge
Rating

Enclosure

Options
Blank
A = Audible Alarms & Dry Contacts
E = Remote Indicator (on 6ft cable)
L = Deletes L-N protection
G = Deletes L-G protection
N = Deletes N-G protection
R = Alternate lead length

Common System Configurations
01 = 240/120V Split Phase - 1Φ 3W+Grnd (Fig 1)
02 = 208Y/120V Wye - 3Φ 4W+Grnd (Fig 2)
03 = 240/120V High Leg Delta (B High) (Fig 3)
04 = 480Y/277V Wye - 3Φ 4W+Grnd (Fig 2)
05 = 480V Delta - 3Φ 3W+Grnd (Fig 4) & HRG Wye
08 = 600Y/347V Wye -3Φ 4W+Grnd (Fig 2)

STXP

Example
STXP

Other System Configurations Available
06 = 240V Delta - 3Φ 3W+Grnd (Fig 4)
07 = 380Y/220V Wye - 3Φ 4W+Grnd (Fig 2)
09 = 600V Delta - 3Φ 3W+Grnd (Fig 4) & HRG Wye
11 = 120V Single Phase (Fig 5)
12 = 240V Single Phase (Fig 5) - Not split phase
13 = 127V Single Phase (Fig 5)
14 = 300V Single Phase (Fig 5)
15 = 254/127V Split Phase - 1Φ 3W+Grnd (Fig 1)
16 = 277V Single Phase (Fig 5)
17 = 480V Single Phase (1 Hot, 1 Neu, 1 Grnd) (Fig 5)
18 = 480/277 2-Pole, (480/240V Split Phase) (Fig 1)
21 = 220Y/127V Wye - 3Φ 4W Grnd (Fig 2)
41 = 520Y/300V Wye- 3Φ 4W+Grnd (Fig 2)
42 = 415Y/240V Wye-3Φ 4W+Grnd (Fig 2)
43 = 400Y/230V Wye - 3Φ 4W+Grnd (Fig 2)
44 = 440Y/250V Wye - 3Φ 4W+Grnd (Fig 2)
51 = 480V B Corner Grnd Delta, 3Φ 3W+Grnd (Fig 6)
61 = 240V B Corner Grnd Delta, 3Φ 3W+Grnd (Fig 6)
91 = 600V B Corner Grnd Delta, 3Φ 3W+Grnd (Fig 6)
STXP05S1004XE
05

S

100

4X

S

100

4X

E

Wiring Diagrams
Figure 1

}V
}V

Figure 2
Phase A (BLK)

Hot (BLK)

B Phase B (BLK)

A

Neutral (WHT)

N

Hot (BLK)
Ground (GRN)

C

SPLIT
2 Hots, 1 Neu, 1 Grnd

}

Neutral (WHT)
V

Figure 4

Figure 3

Phase C (BLK)
Ground (GRN)

WYE
3 Hots, 1 Neu, 1 Grnd

}

Phase A (BLK)
Phase B (ORNG)

}

V

V

Phase C (BLK)

}

Phase A (BLK)

Neutral (WHT)

Phase C (BLK)
Ground (GRN)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

DELTA & HRG WYE
3 Hots, 1 Grnd

Phase A (BLK)

Ground (GRN)

Ground (GRN)

HI-LEG DELTA (B High)
3 Hots, (B HIGH),
1 Neu, 1 Grnd

}V

Hot (BLK)

V

Phase B (BLK)
Phase C (BLK)

Neutral (WHT)
Ground (GRN)

Figure 6

Figure 5

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd

N

Performance Data
UL 1449 THIRD Edition (Sept 2009) Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
01
02
03
04
05
08

=
=
=
=
=
=

240/120V Split Phase
208Y/120V 3Ø Wye
240Y/120V B High Leg Delta
480Y/277V 3Ø Wye
480V 3Ø Delta
600Y/347V 3Ø Wye

L-N

L-G

N-G

L-L

Type

In

SCCR

MCOV

600
600
600/1200
1200
1500

700
700
700/1200
1200
1800
1500

500
500
500
1000
1500

1000
1000
1000
1800
1800
2500

Type 1
Type 1
Type 1
Type 1
Type 1
Type 1

20kA
20kA
20kA
20kA
10kA
10kA

100kA
200kA
200kA
200kA
200kA
200kA

150
150
150 / 320
320
552
420

Available Accessories*
FMKITC = Flush mount kit.
RM = Remote monitor
*Consult factory for details.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

N11

Surge-Trap® Type 1 XT Series SPD
The Surge-Trap® Type 1 XT Series offers Advanced Technology. It utilizes large block
50kA Thermally Protected MOV’s. With line or load side installation flexibility, this unit
is a great fit from the service entrance all the way down to each distribution and/or
branch panel.

Features/Highlights:

Applications:

•• UL 1449 Third Edition Listed (Sept

•• Service Entrance
•• AC Distribution

2009)
•• Type 1 SPD – All UL required OCP

•• Power supplies

& safety coordination included

•• Drive Protection

inside

•• Large Control Panels

•• Can be installed line-side or loadside of main disconnect

•• Telecommunications
•• IT / Data centers

•• 20kA Nominal discharge current
•• 200kA SCCR (most models)

Ratings:

•• UL 96A Lightning Protection Master

Surge	 : 100kA per phase

Label compliant (@20kA In)

			

•• NEMA 4X polycarbonate enclosure

: 200kA per phase

Volts	: 120V to 600V

– UL 746C(f1) & UL 94-5VA

SCCR 	 : 200kA SCCR (most 	

•• TPMOV® Technology Inside

		

•• All MOV suppression elements

models)

Nominal discharge current

monitored

	: 20kA (most models)

•• Filtering - AC sinewave tracking

Operating & storage temp

filter with EMI/RFI filtering up to

		

-50dB from 10khz to 100mhz

: -250C to +600C

Enclosure

•• Phase-loss monitoring (toggles

	

LED and dry contacts)

: NEMA 4x

•• Ten-year Warranty

Approvals:

Dimensions and Weight

•• UL 1449 Third Edition, cUL, UL
1283 R/C
•• UL File: VZCA.E210793
•• RoHS Compliant
•• IEC 61643, CE
•• Burn-In tested prior to shipment
•• UL 96A lighting protection
master label

Weight: 5lbs (2.3kg)

N12

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Surge-Trap® Type 1 XT Series SPD
Catalog Numbers - Ordering System
STXT

System Voltage

S

Common System Configurations
01 = 240/120V Split Phase - 1Φ 3W+Grnd (Fig 1)
02 = 208Y/120V Wye - 3Φ 4W+Grnd (Fig 2)
03 = 240/120V High Leg Delta (B High) (Fig 3)
04 = 480Y/277V Wye - 3Φ 4W+Grnd (Fig 2)
05 = 480V Delta - 3Φ 3W+Grnd (Fig 4) & HRG Wye
08 = 600Y/347V Wye -3Φ 4W+Grnd (Fig 2)

Example
STXP

Enclosure

Options
Blank
A = Audible Alarms & Dry Contacts
E = Remote Indicator (6ft cable)
L = Deletes L-N protection
G = Deletes L-G protection
N = Deletes N-G protection
R = Alternate lead length

100
200
200
200
200
200

Other System Configurations Available
06 = 240V Delta - 3Φ 3W+Grnd (Fig 4)
07 = 380Y/220V Wye - 3Φ 4W+Grnd (Fig 2)
09 = 600V Delta - 3Φ 3W+Grnd (Fig 4) & HRG Wye
11 = 120V Single Phase (Fig 5)
12 = 240V Single Phase (Fig 5) - Not split phase
13 = 127V Single Phase (Fig 5)
14 = 300V Single Phase (Fig 5)
15 = 254/127V Split Phase - 1Φ 3W+Grnd (Fig 1)
16 = 277V Single Phase (Fig 5)
17 = 480V Single Phase (1 Hot, 1 Neu, 1 Grnd) (Fig 5)
18 = 480/277 2-Pole, (480/240V Split Phase) (Fig 1)
21 = 220Y/127V Wye - 3Φ 4W Grnd (Fig 2)
41 = 520Y/300V Wye- 3Φ 4W+Grnd (Fig 2)
42 = 415Y/240V Wye-3Φ 4W+Grnd (Fig 2)
43 = 400Y/230V Wye - 3Φ 4W+Grnd (Fig 2)
44 = 440Y/250V Wye - 3Φ 4W+Grnd (Fig 2)
51 = 480V B Corner Grnd Delta, 3Φ 3W+Grnd (Fig 6)
61 = 240V B Corner Grnd Delta, 3Φ 3W+Grnd (Fig 6)
91 = 600V B Corner Grnd Delta, 3Φ 3W+Grnd (Fig 6)
STXT04S2004XA
4

STXT

Surge
Rating

S

S

4X

200

4X

A

Wiring Diagrams
Figure 1

}V
}V

Figure 2
Phase A (BLK)

Hot (BLK)

B Phase B (BLK)

A

Neutral (WHT)

N

Hot (BLK)
Ground (GRN)

SPLIT
2 Hots, 1 Neu, 1 Grnd

C

}

Neutral (WHT)
V

}

}

V

V

Phase C (BLK)

Ground (GRN)

}

Phase B (BLK)

DELTA & HRG WYE
3 Hots, 1 Grnd

}V

Hot (BLK)

V
Neutral (WHT)

Phase A (BLK)
Phase C (BLK)
Ground (GRN)

Ground (GRN)

Ground (GRN)

HI-LEG DELTA (B High)
3 Hots, (B HIGH),
1 Neu, 1 Grnd

Figure 6

Figure 5

Phase A (BLK)

Phase C (BLK)

Neutral (WHT)
Ground (GRN)

Phase C (BLK)

WYE
3 Hots, 1 Neu, 1 Grnd

Figure 4

Figure 3
Phase A (BLK)
Phase B (ORNG)

SINGLE POLE
1 Hot, 1 Neu, 1 Grnd

CORNER GROUND
DELTA (B grounded)
2 Hots, 1 Grnd

Performance Data
N

UL 1449 THIRD Edition (Sept 2009) Test Data
Voltage Protection Ratings (VPR - 3kA)

Common North American Systems
L-N

L-G

N-G

L-L

Type

In

SCCR

MCOV

01

=

240/120V Split Phase

700

700

600

1000

Type 1

20kA

100kA

150

02

=

208Y/120V 3Ø Wye

700

700

600

1000

Type 1

20kA

200kA

150

03

=

240Y/120V B High Leg Delta

700/1200

700/1200

600

1000/2000

Type 1

20kA

200kA

150 / 320

04

=

480Y/277V 3Ø Wye

1200

1200

1200

2000

Type 1

20kA

200kA

320

05

=

480V 3Ø Delta

-

1800

-

2000

Type 1

10kA

200kA

550

08

=

600Y/347V 3Ø Wye

1500

1500

1500

2500

Type 1

10kA

200kA

420

Available Accessories*
FMKITC = Flush mount kit.
RM = Remote monitor
*Consult factory for details.

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

N13

TPMOV® Technology
Thermally protected MOV (TPMOV) technology
Mersen’s patented TPMOV® technology eliminates common failure
modes that occur in the field with standard metal oxide varistors. Internally the
TPMOV is comprised of a voltage clamping device and a disconnecting apparatus
that monitors the status of the metal oxide disk making the TPMOV a fail-safe
device. In the event of an overvoltage breakdown the metal oxide disk is securely
disconnected from the system power by an arc shield. Upon failure the TPMOV is
also equipped with a visual pin indicator as well as a normally open micro-switch
providing remote indication, if applicable.
The TPMOV is rated for 50kA - 8/20μs peak surge current and is available for
maximum continuous operating voltages (MCOV) from 150V to 550VAC. No
additional fusing or overcurrent protective device is required when using the
TPMOV as compared to most MOV’s on the market today.
The TPMOV footings are similar to that of equivalent voltage ratings of traditional
25 to 40mm MOV’s. The TPMOV can be utilized on existing systems that utilize
traditional MOV’s without costly board redesigns. See dimensional drawings on the
following page.

Ratings:
Volts	: 150V - 550V AC
SCCR 	 : 200kA
Nominal discharge current	
		

Features/Benefits:

Applications:

•• High energy capacity

•• Surge protective devices and

•• Consistent footprint with

: 20kA 8/20μs

Operating & storage temp
			

: -250C to +600C

systems

25–40mm MOV’s

•• AC / DC distribution systems

•• Built-in visual/remote indication

•• High voltage power supplies

•• Wave solderable

•• Telecommunications equipment

•• No additional overcurrent

•• Motor control systems

protection device (fuses) required

•• Computer related products
•• PLC applications

Approvals:

•• Power transfer switches

•• UL 1449 Third Edition Approved,
File E210793
•• Type 4 UL Recognized

Catalog - Ordering System

Component

Select the MCOV and add it to the prefix of the Part Number to obtain the
appropriate Catalog Number
MCOVs (xxx))

N14

Part No

Description

150

TPMOV

180

(TPMOV with…)

•• CE
•• RoHS Compliant

Pkg Operating
Qty

Temperature

Tabs & Microswitch with Long Leads

10

-25 ºC to 60 ºC

xxxTPMOV-HV

Tabs & Heavy Duty Microswitch with Long Leads

10

-25 ºC to 60 ºC

270

xxxTPMOVS

Microswitch with Short Leads, no visual indicator

10

-25 ºC to 60 ºC

320

xxxTPMOVSL

Microswitch with Short Leads, no visual indicator

500

-25 ºC to 60 ºC

420

xxxTPMOVS-HV

Tabs & Heavy Duty Microswitch with Short Leads

10

-25 ºC to 60 ºC

510

xxxTPMOVSL-HV

Tabs & Heavy Duty Microswitch with Short Leads

500

-25 ºC to 60 ºC

550

xxxTPMOVST

Tabs & Microswitch with Short Leads

10

-25 ºC to 60 ºC

xxxTPMOVSLT

Tabs & Microswitch with Short Leads

500

-25 ºC to 60 ºC

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

TPMOV® Technology
Product Performance Data
Maximum
Cat. No.

Continuous

Prefix

Operation

Discharge

Protection Rating

180
180
270
320
420
510
550

SCCR (A)

Current

(VPR) (Vpk)

Voltage (VAC)
*150TPMOV
*180TPMOV
*270TPMOV
*320TPMOV
*420TPMOV
*510TPMOV
*550TPMOV

Nominal

Voltage

(kA)

700
800
800
1000
1500
1500
1500

20
20
20
20
20
20
20

200,000
200,000
200,000
200,000
200,000
200,000
200,000

Dimensional Drawing of TPMOV
.03
0.8
.25
6.3

2X

.100 MAX
2.5
(BLOWN
POSITION)

.03
0.7

.23 ±.01
5.7 ±0.3
2X

.13
3.2

MOV LEAD

CONTACT LEAD

1.733 ±.005
44 ±0.1

.62 ±.01
15.7 ±0.3
2X

.01
0.3

.47 ±.01
11.9 ±0.3

.28
7.1

.01
0.3

.02
0.5

.146 ±.005
3.7 ±0.1
(SEE NOTE 1)
A
(SEE NOTE 1)

.407 ±.005
10.3 ±0.1
(SEE NOTE 1)

1.375 ±.025
34.9 ±0.6
(SEE NOTE 1)

CONTACT LEAD

.20
5

MOV LEAD

1.24
31.4

.627 ±.005
15.9 ±0.1

1.687 ±.005
42.8 ±0.1

Board Layout Dimensions

N

2X Ø .039
SWITCH LEADS
.197

.231
.844

2X .325

2X .037

MOV LEAD
A

.627

CONTACT LEAD
.146
.407
1.375
1.687

SCALE: 2:1
TOLERANCES: ± .005

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

N15

VSP MOV Protector Fuse
Surge Suppression Fuses
Mersen surge suppression fuses are specially designed to address the protection
of SPD systems. Our surge suppression fuses have been specially designed to
withstand 8x20 µSec surge pulses without opening, allowing the SPD system to
react to the surge. All surge suppression fuses have a 8x20 µSec surge rating, not a
continuous current rating. Under AC short circuit conditions these surge suppression
fuses are very current limiting.

Features/Benefits:

Applications:

•• VSP fuses rated 600VAC, 200kA I.R.

•• Protection of surge protection

•• Surge ratings of 5-100kA 8 x 20

devices (SPD)
•• Coordination with other protection

µSec capacity
•• Various mounting configurations

devices

ferrules, blade, bolt-in, pc board
mount

Ratings
Volts	: 600V AC
Surge Rating
	

Catalog Numbers
Catalog No.

Voltage

8x20 µSEC

Melting l2t

Clearing l2t

IPEAK@ 100kA 60

(Connection Suffix)

Rating (AC)

Surge Rating

(A2S)

(A2S)

Hz (A)

VSP5-2,-R,-H,-S

600V

5,000

341

936

3,652

VSP10-2,-R,-H,-S

600V

10,000

1,541

3,744

5,794

VSP15-2,-R,-H,-S

600V

15,000

3,072

8,424

7,591

VSP20-2,-R,-H,-S

600V

20,000

4,992

14,400

9,194

VSP30, -2

600V

30,000

12,507

33,696

12,044

VSP40, -2

600V

40,000

19,543

59,904

14,588

VSP50, -2

600V

50,000

32,020

93,600

16,925

VSP60, -2

600V

60,000

42,808

134,784

19,110

VSP70, -2

600V

70,000

61,152

183,456

21,176

VSP80, -2

600V

80,000

79,872

239,616

23,146

VSP90, -2

600V

90,000

99,000

303,264

25,034

VSP100, -2

480V

100,000

121,500

374,400

26,854

VSP100-XL

600V

100,000

121,500

374,400

26,854

: 5-100kA 8x20 µSec

	

600 VAC

I.R.	

: 200kA	 I.R. AC	

Approvals
•• UL Recognized Component
File E60314, Vol.3 Special
Purpose MOV Protector

Recommended Fuse Blocks for VSP Fuses
VSP(5-20)-2
Number
of Poles

Double Quick
Connects

Pressure
Plate with
Double Quick
Connects

Copper
Box
Connector

Number

Catalog Number

of Poles

ADDER

30310

30320

30350

ADDER

60305J

60315J

60325J

1

30311

30321

30351

1

60306J

60316J

60326J

2

30312

30322

30352

2

60307J

60317J

60327J

3

60308J

60318J

60328J

3

N16

Screw with

VSP(30-100)-2

30313

30323

30353

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

VSP MOV Protector Fuse
VSP (5-20)-2,R,H,S

PC BOARD MOUNTING

VSP (30-100)-2

VSP30-100

N

VSP100-XL

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

N17

Surge Switch	
Disconnect Switch
The Surge Switch is an extremely compact, high performance, manually operated,
non-fused switch. It is specifically designed to withstand the high surge current of
200kA with an 8x20 µs waveform seen in today’s transient voltage surge protection
device (SPD) applications. Mersen’s Surge Switch utilizes a unique contact design
that actually clamp contacts tighter during a surge.

Features/Benefits:

Applications:

•• Only surge rated switch available

•• Surge protective device (SPD)
panels up to 600VAC, 200kA 8x20

today

µs waveform

•• Compact footprint
•• Extremely reliable
•• Defeatable pistol handles
automatically relatch when panel
door is closed, no tool necessary

Ratings:

to reset latch

Volts	: 600V AC

•• Direct mount handle option

Amps	 : 600A
Surge Rating

Catalog Numbers

N18

	

: 200kA 8x20 µs wave form

Catalog No.

Description

SS200

3-pole, surge switch, 200kA 8x20 µs

SS200-4

4-pole, surge switch, 200kA 8x20 µs

HADSS200

Direct mount black handle

HGPB

External black handle, NEMA 1,3R, 12 (IEC IP 54), defeatable

HGPR

External red handle, NEMA 1,3R,12 (IEC IP 54), defeatable

HGPB4

External black handle, NEMA 1,3R,124,4X (IEC IP 65), defeatable

HGPR4

External red handle, NEMA 1,3R,12,4,4X (IEC IP 65), defeatable

SG200-10

Shaft, 7.9 in (200 mm)

SG320-10

Shaft, 12.6 in (320 mm)

Approvals:

SG400-10

Shaft, 15.7 in (400 mm)

TS200SS

Terminal Shield, 3-pole

•• UL Listed Guide NRNT, File

TS2004SS

Terminal Shield, 4-pole

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

E224922

www.barr-thorp.com

Surge Switch
Dimensions (dual dimensions: in/mm)
SS200

SS200-4

PISTOL HANDLE TYPE G

HADSS200

HGPB
HGPR
HGPB4
HGPR4
3.15
80

O - OFF

DOOR DRILLING

2.75
70

2"

90°

4.73
120

I - ON

2.78
70.5

2.56
65

2"

1 8"

4 ø 4.5

50

o -OFF

50

2.87
73

90°

11 4"

0.67
17

ø 31

-ON

N

PISTOL HANDLE TYPE G
SS200/SS200-4

Shaft Length
in

mm

h Minimum

Dimension

h Maximum

Dimension

in

mm

in

mm

7.9

200

4.88

124

9.29

236

12.6

320

4.88

124

14.01

356

15.7

400

4.88

124

17.16

436

For the most current product performance data visit us-ferrazshawmut.mersen.com and use catalog search.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

N19

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Resources & Tools
Strapped for time? Try some of these time-saving resources to
enhance your electrical safety initiatives.

Your problem:
Thanks to

O

downsizing,

Resources & Tools

restructuring, and
other cost-saving
initiatives, your
facility is running

• Arc Flash Info Center........................ O2
• Electrical Services............................. O3

lean and mean. You

• Electrical Safety Seminars................ O4

have to do much

• Fuse Control™ Program................... O5

more with a lot less.
And, you have to figure out how to do it safely and effectively.
Our solution: Our goal is to offer the right solution for the
right application or business challenge. Need a quick, effective
tool that will help you find the best heatsink to fit your space? Try
our R-Tools® 3D Heatsink Thermal Modeling. Need to specify

• High Power Test Lab......................... O6
• Protection Intelligence Quotient
(PIQ) Quizzes.................................... O7
• R-Tools® 3D Heatsink Modeling........ O8
• Select-A-Fuse® Software................... O9

the right fuse fast? Explore our Select-A-Fuse® Software. Want a

• Power Electronics Solutions............ O10

sure fire way to 5S your fuse maintenance program and reduce

• Solar Power Solutions..................... O11

your inventory by 25% or more, then explore our innovative Fuse
Control™ program. We have these and many other timesaving
resources.

• Wind Power Solutions..................... O12
• Technical Services Support............. O13

Want more information fast? If you want more in depth
information on these resources & tools, visit our website at
us-ferrazshawmut.mersen.com, or call Technical Service

O

Support at 978-465-4853.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Arc Flash Info Center™
Learning about
arc flash makes
you an even more
valued resource.

Here’s what you’ll discover on the
Arc Flash Info Center:
Arc Flash Hazard Background
• The causes

Arc flash is a daily threat

• Arc Flash hazard

to your customers. It can

• Test lab examples

blind, burn, or even kill

• Regulations

in an instant, and there’s
no one, sure protection.

Hazard Analysis

But there is an excellent

• Why hazard analysis?

defense: knowledge. The more you know about how arc

• Nine steps of Arc Flash hazard analysis

flash occurs, the better you can help your customers stay
safe, protect their equipment, and comply with OSHA

Reducing Arc Energies with Fuses

requirements.

• Using current-limiting fuses
• Understanding current-limiting fuses

A lot has been written about arc flash—a simple Internet

• Recommended fuses for Arc Flash mitigation

search alone finds more than 3 million references. But

• Arc Flash calculator

you don’t need to search website after website for the
accurate, up-to-date information you need to protect your

Getting Help

workers. Just visit the Arc Flash Info Center.™

• Technical services
• Training

Developed by Mersen, the Arc Flash Info Center is your

• More information

online guide to understanding arc flash requirements

	

- Books & standards

and improving plant safety. From a startling look at an

	

- Articles & white papers

arc blast to explanations of current-limitation and hazard

	

- Literature

analysis to an interactive Arc Flash calculator, it gives you

	

- References

an up-close view of this vital topic.

• Helpful links

We’ve been heavily involved in arc flash research and

FAQs

testing for many years, amassing a valuable base of
information that’s available to you—free. You’ll learn how

What’s New

arc flash protection is the sum of many factors: routine

• News releases

electrical safety analysis, staff training, appropriate circuit

• Events

protection devices, and the right personal protective
equipment (PPE). Considering how your customers’
safety can go up in a flash, that’s valuable information to
share. Find out more about arc flash and the products that
can mitigate it by visit the Arc Flash Info Center.

us-ferrazshawmut.mersen.com/arcflash

O2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Electrical Services
Mersen has built a reputation for

Short Circuit Analysis & Coordination Studies

providing innovative electrical

Mersen’s seasoned electrical safety experts are

protection products that meet

available to provide analysis of short circuit current

NEC, UL, CSA, IEC, ANSI/IEEE,

faults, identify electrical equipment deficiencies and

CE, NFPA, and other critical safety

inappropriately sized components, conduct circuit

standards. In fact, many of our

protection coordination studies, and pin-point potential

respected field engineers serve on

short circuit current rating (SCCR) issues.

leading electrical safety codes and standards committees.
Field Inspection and Data Collection Supervision
Today, Mersen brings its highly regarded electrical protection

Electrical engineers are available to perform field

expertise to you through our new suite of Electrical Services.

inspections in order to help ensure your facility is

Discover why more Safety Managers, Facility Engineers and

compliant with today’s electrical codes. Our team is

Maintenance Supervisors turn to Mersen to help them put

also on hand to supervise data collection and input to

electrical safety to work for their companies. We offer:

ensure the accuracy of arc flash calculations.

Electrical Safety Project Management

Hazard Labeling

Mersen can coordinate some or all of the electrical safety

After we complete your arc flash energy calculations,

requirements for a facility. This may include initial assessment

Mersen helps you satisfy the NEC 110.16 code and

through program development, implementation or training. Or

NFPA 70E standards requiring Arc Flash Warning

you may choose this service on a project basis for assistance

Labels on all equipment that could be energized while

with arc flash analysis, integrating the latest NFPA 70E

being worked on.

requirements, development of Request for Quote (RFQ)
packages for Arc Flash studies, and more.

Electrical Safety Program Audit
Mersen is available to provide an objective review of

Arc Flash Hazard Analysis

your facility’s electrical hazards and safety manual

Turn to our experienced team of electrical safety engineers

for NFPA 70E and OSHA compliance in a confidential

to analyze your electrical system’s exposure to arc flash

audit process.

OSHA. A standard analysis includes: arc flash, shock

Product Analysis & High Power Testing

and other hazards assessment, arc flash incident energy

Turn to Mersen to help with forensic analysis of

calculations, arc flash protection boundary calculations,

electrical products. We can help identify fault levels,

determining hazard risk categories, required PPE, and

durations, temperatures and target the reason why the

recommended warning labels for electrical equipment.

products operated.

One-Line Drawings

Need More Information?

The foundation of a strong electrical safety program is

For additional information, please contact us:

built upon one-line electrical drawings that are current and

Email: 	electricalservices.nby@mersen.com

accurately represent the facility’s electrical system with all

Call: 	

978-462-6662

O

and other electrical hazards in accordance with NFPA 70E and

of the electrical components, power sources, and electrical
equipment located and clearly identified.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

O3

Electrical Services Seminars & Training
The standard electrical training programs we
can bring your facility.

Short Circuit Current

Introduction to Arc Flash Hazards – This is a 2, 4, or

Panel Builders –

Rating (SCCR)
calculations for

6-hour seminar ranging from an overview to a thorough

This 4-hour program

session. The objective is to present an overview of 70E

explains to panel

and to explain selected OSHA and 70E requirements

builders the whys of

relevant to arc-flash and fusible protection. This seminar

SCCR requirements. It

also discusses real world examples.

includes examples of
calculating SCCR in accordance with UL 508A and typical

Arc Flash Safety for Equipment Installers –

solutions to upgrading panel SCCR ratings.

This 6-hour seminar presents an overview of 70E
requirements relevant to arc flash for individuals that will

Use of Power Distribution Fuses for 600 Volts and Below

be working within their customers’ facilities. The NFPA

– This 4-hour seminar is intended to teach the fundamentals

Electrical Program Safety Book is discussed in reference

of selecting fuses for power distribution applications including

to different facility safety programs. This gives a basic

motors and transformers 600 volts and less. It covers normal

understanding of arc flash hazards and the value of

applications, UL fuse types, and gives an appreciation of the

safety programs. Relevant laws, codes and standards

strengths and limitations of fuses.

are discussed.
Basics of Selective Coordination – This 4-hour
General Electrical Safety for Shock, Arc Flash, and
Arc Blast – This 6-hour seminar combines arc flash

program explains the National Electrical Code requirements
for selective coordination. It gives the student a conceptual

safety with shock hazard safety for a full understanding

understanding of selective coordination. It reviews some

of electrical safety. It begins with laws, codes, and

examples using time current curves with circuit breakers

standards, then progresses to a detailed explanation of

and fuses for NEC compliance.

the hazards, and ends with PPE and test equipment.
Customized Electrical Training Services –
Complete Arc Flash Safety – This is a two or three day

Combinations of standard courses can be customized for

seminar. It introduces OSHA, key national standards, and

your individual facility, equipment, and procedures. Some

standards development organizations. The seminar gives

of the more common requests are below:

understanding of electrical hazards, proper work practices,
and related grounding considerations. It also reviews how

Industrial Electricity: Basics and Troubleshooting – 3 days

PPE and ground fault items can increase safety.

National Electrical Code Basics – 3 days
Grounding and Bonding – 2 days

2008 National Electrical Code Over-Current
Protection Updates – This 4-hour seminar reviews the

Hazardous Locations – 3 days
Industrial High voltage Safety – 2 days

most important code changes pertaining to overcurrent
and overvoltage protection. These topics include Short

Need More Information?

Circuit Current Ratings (SCCR), interaction with UL 508A,

For additional information, please contact us:

safety labeling requirements, surge suppressors, selective

Email: 	electricalservices.nby@mersen.com

coordination requirements, and other changes affecting

Call: 	

978-462-6662

overcurrent ratings of equipment.

O4

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fuse Control™ Program
Mersen’s Fuse Control™ program is a powerful combination of
circuit protection products and services designed to help you
get control of your facility’s inventory, operating costs, code
compliance and workplace safety.
Developed by Mersen and refined through extensive field

Implementing Fuse
Control in
Three Easy Steps
Storeroom Audit and Database Analysis

research, Fuse Control is a simple program that packs a lot of
power. It will give you the edge you need to mitigate arc flash
hazards, achieve code compliance, reduce inventory by 25%

Consolidation Report & Plan

or more — and offer the highest grade overcurrent protection
available. Get Fuse Control and enjoy these five benefits:

Implementation

• Improved workplace safety
• Easier electrical code compliance
• Reduced downtime associated with electrical failures
• Streamline inventory - as much as 25% or more
• Run Leaner and decrease operating costs
How can one program deliver such benefits?
It’s easy! Let the fuses do
the work. The key lies in
consolidating your current
inventory and installed

Free Resources
• Fuse Control Guide - us.ferrazshawmut.com/oem/
resources/literature/FuseControlGuide-Rev1.pdf
• Inventory Template in MS Excel us.ferrazshawmut.com/about-you/fusecontrol.cfm
• Bin Labels Template in MS Word us.ferrazshawmut.com/about-you/fusecontrol.cfm

overcurrent protective devices
into one fuse line - Mersen’s
innovative current-limiting,
arc flash mitigating, Amp-Trap
2000® fuse family.

Need More Information?
For additional information, please contact us:
Email: 	 info.nby@mersen.com
Call: 	

978-462-6662

Order Fuse Control and receive a FREE Fuse Inventory
Audit & Analysis
Take action today to get control of your inventory, contact a
Mersen Sales Representative to initiate your Fuse Control
program today. The initial storeroom audit and database
analysis is very simple and will take up little of your time or

O

resources. Also, did we mention it is free!
Ask your Sales Representative about the Mersen Fuse
Control program today.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

O5

High Power Test Lab
Our focus on efficiency makes the Mersen test facilities

To schedule test

extremely productive and affordable for all your

time, contact us

testing needs. Our customers turn to us to avoid the

at:

inconveniences of long lead-times for test dates, and
to gain the advantages of rapid setup and change over

Mersen

times (e.g., circuit-switching in five minutes vs. one hr.)

Newburyport

allowing us to provide you more “shots” per day. We

Laboratory

appreciate that our customers expect flexibility, and we

Phone:

make every effort to accommodate their unique testing

978-465-4834

requirements.

Fax:
978-462-7934

Mersen offers our customers global test capabilities for

Email: craig.

testing products in North America (Newburyport, MA) or

mckenzie@mersen.com

in Europe (Saint Bonnet, France). Our labs are ready
and able to meet all your test requirements from UL or

Mersen Lyon Laboratory

CSA approval testing in North America to IEC testing in

Phone: +33 (0) 4 72 22 66 31

Europe.

Fax: +33 (0) 4 72 22 66 12
Email: christophe.turbidi@mersen.com

This is why innovative and successful companies who
manufacture equipment like AC and DC drives, soft

When a test date has been arranged, the client will be

starters, UPS’s, lighting controls, circuit breakers, MCC,

sent an Engineering Test Agreement which must be filled

industrial controls, cables, surge suppression devices

out and returned prior to the test date. This agreement

and many other electrical products select Mersen and

verifies the test date, and sets forth contract conditions

our global test capabilities as their partner when it comes

for the client and the lab. Liability and responsibility are

to critical design and approval testing. They value our

explained in the test agreement.

on-site engineering trouble-shooting expertise and
Requirements

consultation services.

• Client Purchase Order
Our facilities in North America and Europe have the
capability to test from the smallest components to large

• All witnesses to test must conform to
Test Lab Visitor’s Safety Policy

complete systems such as motor control centers and

• Clients must read and sign Visitor’s Safety Policy

power distribution panel boards. Our lab provides precise

• Test Lab recommends that the client have an engineer

graphical representation of even the lowest levels of

present during actual testing to ensure compliance to

current, voltage and time.

any special requirements

To keep you and ourselves competitive, we are

Testing

continually reviewing and updating our data acquisition

• Summary sheet of test lab charges is available on

technologies, lab design, and test procedures. Turn to

request and will be sent with the Engineering Test

the Mersen high power test labs for expert, effective,
accurate, and affordable high power electrical testing.

Agreement
• Testing is normally run in accordance with recognized
standards such as UL, CSA, MSHA, and IEC.
• All testing is treated with the strictest confidential
awareness

O6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

PIQ Quiz
Come see what’s new with PIQ

Read what our PIQ fans have to say...

Every quarter,
Mersen features a

The PIQ Quiz participants are engineers, electricians,

new opportunity to

design and specifying engineers, plant managers,

test your knowledge

distributors, consultants, and students. Like you, they

of electrical

are dedicated to electrical protection. They like the

protection and a

quizzes -and we bet you’ll like them too. Here’s what

new chance to win

they’ve had to say:

a prize. What are
we offering today?

• The quiz was very user friendly. The demonstrations

Visit the PIQ

made them more memorable.

Quiz at: us-

• Great, informative graphics. My first thought on the

ferrazshawmut.

first question was ‘surge,’ but picked ‘sag’ instead.

mersen.com/PIQ

The explanation that followed was very good.

At the conclusion of every
quiz, you are invited to enter
your name into the contest
and you can check out the
“Learn More” page where
you’ll find a host of additional
resources on the featured quiz
topic - white papers, articles,
calculators, brochures and
more! You can also download

• This is a simple and good test to check and update

4XL]1RWHV
XVIHUUD]VKDZPXWFRP3,4$UFKLYH

$UF)ODVK%DVLFV
How much do you know about Arc Flash Hazards?
Did you know that the monetary cost of a single arc flash incident can easily
exceed $1 million per incident, including medical expenses and the cost
of equipment replacement, downtown and insurance? Maybe even more
alarming is the fact that the explosive energy released during an arcing fault
will send more than 2,000 workers to burn centers this year. In most cases,
this can be prevented with the proper knowledge of Arc Flash hazards and
prevention.
Question 1 of 3 Which of the following is the NFPA definition of an
Arc Flash Hazard?
An Arc Flash Hazard is defined by National Fire Protection Association
(NFPA), as:
A. A dangerous condition associated with the possible release of energy
caused by equipment short circuiting.
B. A dangerous condition associated with the possible release of energy
caused by an electric arc, or
C. A dangerous condition associated with the possible release of molten
metal caused by equipment exploding.
Question 2 of 3 Which of the following describes the explosive
nature of an Arc Flash?
A. An extremely bright flash of light occurs
B. It produces some of the highest temperatures known to occur on earth
C. Energy released is a function of system voltage, fault current magnitude
and fault duration
D. All of the above
An explanation regarding the nature of Arc Flashes
The many hazards created by arcing faults in today’s industrial power
systems arise from two factors: the tremendous amounts of energy that
can be delivered to such arcs and the workers’ close proximity to them.
The development of a high-current arcing fault is like an explosion. When
an arcing fault is being established, current begins passing though ionized
air. Large volumes of ionized gases, along with metal from the vaporized
conductors, are rapidly expelled. As the arc runs its course, electrical energy
continues to be converted into extremely hazardous forms of energy.
Some additional facts about Arc Flashes
t As the arc is first established, an extremely bright flash of light occurs.
The intensity of the light can cause immediate vision damage.
t The electric current flowing through the ionized air can create some
of the highest temperatures known to occur on earth – up to 35,000
degrees Fahrenheit. This is 4x the surface temperature of the sun!
Even at much lower levels, conventional clothing ignites, causing
severe, often fatal burns.
t The intense heat from the arc causes the air to suddenly expand
producing a blast of very strong air pressure. This thermoacoustic
effect results in a shock wave with impulse sounds that can rupture
eardrums, collapse lungs, and cause fatal injuries.

t

All known materials are vaporized at this temperature, subsequently
expanding in volume. The resultant air blast can eject molten metal
to great distances with extreme force. The molten metal can ignite
conventional clothing and the shrapnel that’s ejected can result in
physical trauma to the worker.

Question 3 of 3 Which of the following could cause an arc flash?
A. Spark discharge from accidental touching or tools dropping
B. Inadequate short circuit ratings
C. Tracking across insulation surfaces
D. Corrosion or contamination
E. Improper work procedures
F. All of the above
Arcs can be initiated many different causes, including…
Glow to arc discharge resulting from:
t Dust and impurities on insulating surfaces can provide a path
for current, allowing it to flash over and create arc discharge
across the surface.
t Corrosion of equipment parts can create impurities on
insulating surfaces which may also provide a path for current,
allowing it to flash over and create arc discharge across the
surface.
Condensation of vapor and water dripping can cause tracking on the
surface of insulating material, which can create flashover to ground and
potential escalation to phase to phase arcing.
Spark discharge resulting from accidentally touching live exposed parts
or dropping tools on or near equipment may initiate arcs.
Over-voltages across narrow gaps such as those that occur when the
air gap between conductors of different phases is very narrow (due to poor
workmanship or damage to insulating materials) in which case arcs may
strike during over-voltages.
Failure of insulating materials
Electric arcs are also caused by improperly designed or utilized
equipment and improper work procedures.
Additional Resources
t Arc Flash Info Center: us.ferrazshawmut.com/arcflash
t Arc Flash articles, white papers & tech topics
us.ferrazshawmut.com/arcflash/getting_help/articles_whitepapers.cfm

t
t

Ferraz Shawmut Electrical Services: us.ferrazshawmut.com/electrical-services
Fuse Control Program: us.ferrazshawmut.com/about-you/fusecontrol.cfm

our knowledge about protection systems.
• The test was good information for anyone, but
especially people in sales.
• I enjoyed listening to the explanations as to how
things come about. The test is an interesting and selfchallenging device, useful to keep a person up-todate, and knowledgeable of Arc Flash and it’s causes.
• Excellent. I’m the OSHA trained rep in our area. Very

XVIHUUD]VKDZPXWFRPDUFIODVK

T: 978-462-6662 | us.ferrazshawmut.com

our new handy one page
summary of the quiz - the PIQ
Quiz Notes.

good basic safety slides.
• I hope you continue providing tests like these. They
are an excellent source of knowledge in this relatively
new field (solar power).
• Although the info did not pertain to our application, I

the PIQ Quiz Archive...
Explore earlier quizzes
from our PIQ Archive, click
the “Resources” tab on our
website, select “PIQ Quiz”
and click “PIQ Archives.”
Explore earlier topics such as:
• Arc Flash hazard protection
• Overvoltage protection
• Solar power circuit protection
• Selective coordination

always enjoy the information presented in the PIQ.
• It’s the second PIQ quiz that I’ve taken, and I have
found it to be most informative. Thanks for sharing
this valuable information with us.
• The PIQ was a great surprise in my email. I enjoyed
the challenge of the topic and questions.
• It was great to win a prize and learn some very
useful information in the process. The quiz was very
user friendly. The demonstrations made them more

O

There’s more! Discover

memorable.
Find out how much you know. Visit:
us-ferrazshawmut.mersen.com/PIQ

Mersen makes it easy to learn more because we understand
that your customers don’t just trust you; they rely on you. So
trust Mersen to give you the products and the knowledge to be
a real protection pro!
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

O7

R-Tools® 3D Heatsink Modeling
Powerful Thermal Modeling Software
Mersen makes it easy and convenient to quickly and
accurately model various heatsink configurations using
the R-Tools online thermal modeling software program.
R-Tools is completely interactive. It uses analytically
based design tools allowing you to perform the thermal
design of the heatsink concurrent with the optimization
of the electrical and manufacturing elements prior to any
prototype builds and testing. This invaluable resource
reduces your design time and increases the reliability in
your finished product.
The benefits of R-Tools
• Convenient online thermal modeling tool

Need More Support?

• Online and accessible 24/7

Mersen is a company that is easy to do business with.

• Quickly and accurately model heatsinks

Our leading engineers will work with you to develop

• 3-D numerical model

tailored solutions for removing damaging heat from your
electronic systems. Our ongoing commitment to critical

But don’t take our word for it, explore R-Tools today and

research in thermal management, means you’ll benefit

experience the benefits.

from new products and processes that meet the operating
requirements of high heat flux power semiconductor

On the Web:

modules. Using a combination of in-house modeling

us-ferrazshawmut.mersen.com

techniques and third-party labs for design verification,

Click “Resources” and “R-Tools”

Mersen is committed to being your number one resource
for cooling solutions.
Email: 	 	
sales.mis@mersen.com
Manufacturing: 	
905-795-0077
Applications Support: 	
905-795-0077 x258 or x340

O8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Select-A-Fuse® Software
The industry’s first point-and-click,
Windows®-based fuse selection
software, Select-A-Fuse is fast, easy
and accurate. With Select-A-Fuse, you
can quickly and accurately choose the

Look for Our

right overcurrent protection for low- and

New Web-based

medium-voltage motors, power and
control transformers, and general loads.

Program in 2011

With Version 4.1, you can do even more. Because in addition
to product specs, melting time and peak let-thru curves, and
the ability to check fuse coordination, our enhanced Select-AFuse software package features:
• An Arc Flash calculator you can use to calculate incident
heat energies for Mersen’s Amp-Trap 2000® current-limiting
fuses
• Data and selection routines for our low- and medium-voltage
capacitor fuses, High-Speed J fuses and FSPDB finger-safe
power distribution blocks
• A cross-reference list with more than 18,000 entries
Select-A-Fuse will save you time and effort, and best of all, it’s
free. Visit the web address below to get your copy today.
Version 4.1 Select-A-Fuse System requirements:
•• Pentium® PC with Windows 95, 98, NT, ME, XP or 	

	

2000 operating system
•• 16MB minimum RAM
•• 2MB free hard disk space
Download your free copy today at:
us.ferrazshawmut.com/resources/download.cfm?f=1
Coming Soon - SAF Online
Select-A-Fuse software is currently being updated and

O

re-engineered for the web. We’re updating all the
content and will have a brand new, completely
web-based version in 2011!

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

O9

Power Electronics Solutions
You can count on
Mersen as a singlesource supplier
of electrical and
thermal protection
products for Power
Electronics. By
combining our
extensive product
line with the knowledge of our application experts, we have
the unique ability to evaluate your needs and deliver the
right solution.
A global manufacturing company with a century of
experience, Mersen has remained strong and viable
by consistently focusing on our day-to-day mission —
ensuring the integrity of the equipment our devices
protect and the safety of the people working around them.
Our zealous commitment to critical research in electrical
safety has enabled us to turn industry knowledge into
products and services customers can rely on. We
consistently go the extra mile by helping our customers
increase their effectiveness, simplify applications and
enhance productivity.

The Benefits of Mersen:
• Product breadth
• Technical knowledge
• Design assistance from day one
• Global manufacturing
• Innovative, problem solving products like Fabin®
heatsinks, TPMOV® Technology, and the industry’s first
finger-safe UltraSafe™ fuse holders
• Easy to do business with!
Additional Resources
Download Select-A-Fuse® for Power Electronics, Ver. 4.2
- With Select-A-Fuse PE, it’s easy to pick the right fuse
for power electronics applications. There’s no need to sift
through product data or perform tedious calculations. Just
enter load current and other variables and in seconds,
this software responds with viable solutions. Download at:
us.ferrazshawmut.com/resources/download.cfm?f=2
Find your local sales representative:
Click “Where to Buy” at us-ferrazshawmut.mersen.com
Call: 978-462-6662
Email: info.nby@mersen.com

For unbeatable technical support teams, design
assistance in the earliest stages of an application through
to final development, and a customer and sales service
team that is easy to do business with, turn to Mersen.
Product Overview:
• Semiconductor fuses & fuse holders
• High speed fuses & fuse holders
• Control fuses & fuse holders
• Air and liquid cooled heatsinks
• Disconnect switches
• Surge protective devices
• Power distribution blocks
• High power switches
• Medium voltage fuses
Serving Companies that Manufacture:
• Drives
• Induction heating
• Inverters
• Motor controllers
• Rectifiers
• UPS
• Welding equipment

O10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Solar Power Solutions
Circuit Protection Solutions for solar power
generation and distribution systems.

Commercial Solar Power Installation
A

Combiner Box

Drawing on a century of experience - and an ongoing
commitment to critical research in electrical safety in both
traditional and emerging markets - we provide solar power
designers, engineering specifiers, solar power installers and

B

Inverter

solar power equipment manufacturers with innovative circuit
protection products and unbeatable technical support.

D
Utility

C

Generating electricity from solar energy is an extremely
reliable process – as long as it’s properly protected! Mersen
offers a trusted range of circuit protection solutions that will
help protect your solar power investment. Any installation,

Main Electrical Panel

Circuit Protection Components for
Solar Power

whether it’s a stand-alone solar array with a back-up generator
set or a grid-connected system, is vulnerable to fault currents
or lightning.

A

Combiner Box
600VDC fuse solutions
1000VDC fuse solutions

Today, fuses and surge protective devices are the most

UltraSafe™ class CC & midget fuse holders

effective ways of protecting the wiring and electrical

Finger-Safe Power Distribution Block

equipment in a Photovoltaic (PV) system. Fuses protect the

Surge-Trap® surge protective devices

cables between strings of modules from overcurrent damage.

DC-rated disconnect switches

The faulty circuits are isolated allowing the system to continue
generating power. But that protection must be designed,
dimensioned, tested and adapted to the specific features of

B

Inverter
700VDC semiconductor fuses
1000VDC semiconductor fuses

solar applications.

Square body semiconductor fuses
At Mersen, we offer a dedicated range of protection

Surge-Trap® surge protective devices

components specially designed for solar power generation and

Modular fuse holders

distribution including, fuses, fuse holders, wire management

AC/DC-rated disconnect switches

solutions, disconnect switches, and surge protective devices.
For solar power circuit protection solutions you can rely on,
contact Mersen.

C

Main Electrical Panel
600VAC class J fuses
600VAC class CC fuses
UltraSafe™ class J fuse holders

Need More Information?
Here’s how to learn more about Mersen solar power circuit

AC-rated fused Disconnect Switches

protection products:

Surge-Trap® surge protective devices

978-462-6662

Email:	info.nby@mersen.com
Web:	

us-ferrazshawmut.mersen.com

D

O

Call: 	

Utility
Medium voltage E-Rated fuses
Cable limiters
Download Mersen’s solar power
solutions brochure at:
us-ferrazshawmut.mersen.com
Click Resources > Literature.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

O11

Wind Power Circuit Protection
Mersen brings its knowledge, innovation and technical

Download Mersen’s wind power solutions brochure at

expertise to the wind power industry, with a complete line

us-ferrazshawmut.mersen.com > Resources > Literature.

of problem-solving products.
To learn more about how Mersen products can protect
people and equipment:

A wide range of circuit protection solutions are available
for the Nacelle, Utility and Tower Base, including Fingersafe Power Distribution Blocks (FSPDB) Time-delay Class

	

Call: 	

J Fuses (AJT), E-Rated Medium Voltage Current-limiting

	

Email: 	 info.nby@mersen.com

Power Fuses and more.

	

Web: 	 us-ferrazshawmut.mersen.com

978-462-6662

Mersen Electrical Protection
Turbine Component

5

6
1

4

Fuses

Holders

AJT

UltraSafe™

Control Cabinet
Class CC

Disconnect

Surge
Protection

Other

Surge-Trap® SPD

FSPDB

Switch

Medium
2

3

1

Voltage

Associated

NH - G

Holders

Surge-Trap® SPD

Class L

Nacelle

2

Rotor

Medium
3

Stator

Voltage

Associated

NH - G

Holders

Surge-Trap® SPD

Class L
4

HUB

5

Obstruction Lighting

6

Anemometer

AJT
Class CC
AJT
Class CC

UltraSafe™

Surge-Trap® SPD

UltraSafe™

Surge-Trap® SPD

UltraSafe™

Surge-Trap® SPD

Class CC
Midget

7

Heading

12

Base

8

10

9

10

11
9
7

O12

8

Both

11

12

Control Cabinet
(230V)
Control Cabinet
(24V/ 48V)
Inverter for Rotor
Power Supply

NH

NH Holders or

Class L

NH Switch

AJT

UltraSafe™

Class CC
Midget

Disconnect

Surge-Trap® SPD

Surge-Trap® SPD

FSPDB

Surge-Trap® SPD

Cable Protector

Switch
UltraSafe™

PSC
Form101

NH Holder

NH - g

Transformer & Utility

Medium

Lines

Voltage

High Voltage
Switch

Inverter &

Medium

Disconnect

Generators

Voltage

Switch

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

High Voltage
Switch
Heatsinks

Technical Services Support
Circuit Protection Technical Services Support
Mersen’s technical service support is one of the best in the industry
and gives you direct access to expert applications engineers and
an extensive range of technical resources. Count on us for answers
to your most challenging applications questions and for rapid issue
resolution, cross reference support, and technical support for
products such as fuses, fuse blocks and holders, surge protective
devices, power distribution blocks, and disconnect switches. Please
contact us at:
Email: technicalservices.nby@mersen.com
Phone: 978-465-4853
Unable to locate the product you need?
Email technicalservices.nby@merseon and tell us about your application. In a jiffy, we’ll find the circuit protection product
that fits your needs.

Thermal Management Application Engineering Support
The experts on our applications support team are your trusted advisors. Turn to us for design assistance, problem
resolution, and technical support for our air or liquid cooled heatsinks, extrusions, heat pipes and cooling systems.
R-Tools 3D Thermal Modeling Heatsink Tool
R-Tools provides the thermal design engineer with 24/7 access to materials, configurations and operating conditions for a
wide variety of Mersen-based thermal solutions. If you need assistance in the use of R-Tools or the design of a heatsink
that cannot be created on R-Tools, please contact us at:
Email: support.mis@mersen.com
Phone: 905-795-0077 x340 or x258

O

U.S.A: (800) 388-5428

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

O13

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Application Information
Need to know how? You’ve turned to the right place...literally.

Your problem:
objective
is optimum
protection
of motor control
equipment,
power or control
transformers,
cable wiring,
or lighting and heating circuits — you need fast, accurate
information to do the job right. Problem is, not all electrical pros
have the same familiarity with circuit protection theories and
practices.
Our solution: Every application has its unique challenges. But
you’ll find the path to a basic understanding of applied circuit
protection principles in our Applications section. Be it a glossary
of relevant electrical terms. An introduction to fuse construction.
Guidance on reading and applying Peak Let-thru curves. Or a
look at the most common applications.
Want more information fast? For more technical or applicationspecific information, please call our Applications/Engineering
experts, at 978-462-6662; 416-252-9371 in Canada; or visit our
website at us-ferrazshawmut.mersen.com.

P

Application Information

• Definitions ............................................ P2
• Fuse Descriptions................................. P4
• Fuse Construction & Operation............. P5
• How to Read Time Current Curves....... P6
• Low Voltage Motor Protection............... P7
• Medium Voltage Motor Protection....... P13
• Transformer Protection........................ P14
		 General............................................ P14
		 Low Voltage Primary Protection....... P15
		 Secondary Fuses for LV
		 Transformers.................................... P16
		 Medium Voltage Primary Protection.... P17
		 Control Transformers....................... P23
• Surge Trap® SPD, FAQ, Glossary....... P24
• Semiconductor Protection................... P29
• DC Circuit Protection &
	 Fuse DC Ratings................................. P30
• Temperature De-Rating....................... P31
• Let-Thru Current & I2t.......................... P33
• Fuse Let-Thru Current Tables............. P35
• Bus Duct Protection............................ P39
• Capacitor Protection............................ P40
• Cable Protection.................................. P42
• Welder Protection................................ P43
• Motor Starter General Info.................. P44
• Fusible & Non-Fusible
		 Disconnect Switches........................ P45
• Selectivity Between Fuses.................. P54
• Short Circuit Calculations.................... P55
• Properties of Materials........................ P61
• Stranded Copper and Aluminum
	 Cable Data.......................................... P62
• Recommended Tightening Torque for
	 Bolt-on and Stud Mounted Fuses........ P62
• Small Ampere Rating Equivalents....... P62
• Short Circuit Rating............................. P63
• 11 Reasons for Using Current
	 Limiting Fuses..................................... P63
• Fuse Obsolescence............................ P64
• Class 1, Division 2 Locations.............. P65
• Suggested Specs for Mersen Fuses... P66

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P

Whether your

Definitions
Element

Ampacity
cable size, insulation type and the conditions of use.

A calibrated conductor inside a fuse which melts when
subjected to excessive current. The element is enclosed by
the fuse body and may be surrounded by an arc-quenching
medium such as silica sand. The element is sometimes
referred to as a link.

Ampere Rating

Fault

The current a conductor can carry continuously without
exceeding its temperature rating. Ampacity is a function of

The continuous current carrying capability of a fuse
under defined laboratory conditions. The ampere rating
is marked on each fuse. Class L fuses and E rated fuses

Fault Current

may be loaded to 100% of their ampere rating. For all

The amount of current flowing in a faulted circuit.

other fuses, continuous load current should not exceed

Fuse

80% of fuse ampere rating.

Available Fault Current
The maximum short circuit current that can flow in an

An overcurrent protective device containing a calibrated
current carrying member which melts and opens a circuit under
specified overcurrent conditions.

I2t (Ampere Squared Seconds)

A measure of the thermal energy associated with current flow.
I2t is equal to (lRMS)2 x t, where t is the duration of current flow
in seconds.

unprotected circuit.

Bolt-in Fuse
A fuse which is intended to be bolted directly to bus bars,
contact pads or fuse blocks.

Contacts
The external live parts of the fuse which provide continuity
between the fuse and the balance of the circuit. Also
referred to as ferrules, blades or terminals.

Coordination
The use of overcurrent protective devices which will isolate
only that portion of an electrical system which has been
overloaded or faulted. See Selectivity.

Current-Limiting Fuse
A fuse which will limit both the magnitude and duration of

Clearing I2t is the total I2t passed by a fuse as the fuse
clears a fault, with t being equal to the time elapsed from
the initiation of the fault to the instant the fault has been
cleared.
Melting I2t is the minimum I2t required to melt the fuse
element.

Interrupting Rating (Abbreviated I.R.)

The maximum current a fuse can safely interrupt.
Some special purpose fuses may also have a “Minimum
Interrupting Rating”. This defines the minimum current
that a fuse can safely interrupt.

Kiloamperes (Abbreviated kA)
1,000 amperes.

Limiter or Back-up Fuse

current flow under short circuit conditions.

A special purpose fuse which is intended to provide short
circuit protection only.

Current-Limiting Range

Overcurrent

The available fault currents a fuse will clear in less than 1/2
cycle, thus limiting the actual magnitude of current flow.

Any current in excess of conductor ampacity or equipment
continuous current rating.

Dual Element Fuse

Overload

Often confused with time delay, dual element is a term
describing fuse element construction. A fuse having two
current responsive elements in series.

P2

An accidental condition in which a current path becomes
available which by-passes the connected load.

The operation of conductors or equipment at a current level
that will cause damage if allowed to persist.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Definitions
Peak Let-Thru Current (lp)

The maximum instantaneous current passed by a
current- limiting fuse when clearing a fault current of
specified magnitude.

Rejection Fuse Block

A fuse block which will only accept fuses of a specific UL
class. Rejection is a safety feature intended to prevent the
insertion of a fuse with an inadequate voltage or interrupting
rating.

Rejection Fuse

A current-limiting fuse with high interrupting rating and with
unique dimensions or mounting provisions.

Renewable Fuse

A fuse which can be restored for service by the replacement
of its element.

Renewable Element or Link

The field-replaceable element of a renewable fuse. Also
referred to as a renewable link.

Selectivity

A main fuse and a branch fuse are said to be selective if
the branch fuse will clear all overcurrent conditions before
the main fuse opens. Selectivity is desirable because it
limits outage to that portion of the circuit which has been
overloaded or faulted. Also called selective coordination.

Semiconductor Fuse

An extremely fast acting fuse intended for the protection of
power semiconductors. Sometimes referred to as a rectifier
or ultra fast fuse.

Short Circuit

Excessive current flow caused by insulation breakdown or
wiring error.

Threshold Current

The minimum available fault current at which a fuse is
current limiting.

Time Delay Fuse

A fuse which will carry an overcurrent of a specified
magnitude for a minimum specified time without opening.
The specified current and time requirements are defined in
the UL/CSA/NOM 248 fuse standards.

Voltage Rating

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

P

The maximum voltage at which a fuse is designed to
operate. Voltage ratings are assumed to be for AC unless
specifically labeled as DC.

www.barr-thorp.com

P3

Fuse Descriptions
High Voltage (over 34,500V)

Expulsion-Type power fuses are available for nominal
voltages of 46, 69, 115, 138 and 161kV in current ratings
up to 400 amperes. ANSI (American National Standards
Institute) Standards are followed.

Medium Voltage (601-34,500V)
Current-Limiting or Expulsion-Type Power
Fuses
are general purpose fuses available for nominal voltages of
2.4, 2.75, 4.16, 5.5, 7.2, 8.25, 14.4, 15.5, 23 and 34.5kV in
current ratings up to 720 amperes. ANSI and UL Standards
are followed.

PT Fuses

Potential transformers require current limiting fuses or
equivalent on the primary connection side. Standard
PT primary voltages range from 2.4kV to 36kV. Since the
power requirement is low (for relays, metering, etc.) fuses of
the proper voltage are applied in the 1/2 to 5 ampere range.
Several voltage ratings are available, physical sizes vary
among manufacturers.

Low Voltages (600V or less)

Many types of low voltage fuses are classified and identified
for use in 125, 250, 300, 480, or 600V circuits. UL/CSA/NOM
standards are followed. Common types are briefly
summarized below:

Current-Limiting Motor Starter Fuses

are available for nominal voltages of 2.4, 4.8 and 7.2kV in
current ratings up to 36R (650A). These are special purpose
R-Rated fuses for motor short circuit protection only (backup fuses) and are not full-range power fuses. ANSI and UL
Standards are followed.

Summary of Low Voltage Fuses
Fuse Type

Voltage

Ampere Rating

Interrupting Rating – kA

Mersen Part #

600VAC

0-30

200

ATDR, ATQR, ATMR

Class CC

300VDC

0-30

100

ATDR, ATQR

600VDC

0-30

100

ATMR

Class G

480/600VAC

0-20/21-60

100

AG

248-5

Class H (Renewable)

250/600VAC

0-600

10

RF/RFS

248-7
248-6

Class H (Non-Renew)
Class J
Class K-5
Class L

Class RK1

Class RK5
Class T
Semiconductor
Glass/Electronic
Midget
Plug
Cable Protector

P4

250/600VAC

0-600

10

NRN, CRN/NRS, CRS

600VAC

0-600

200

AJT, HSJ, A4J

300VDC

0-30

100

A4J, HSJ(1-10)

500VDC

0-600

100

AJT, HSJ(15-600)

250/600VAC

0-600

50

OT, OTN/OTS

600VAC

601-6000

200

A4BQ, A4BY, A4BT

500VDC

601-3000

100

A4BQ

250/600VAC

0-600

200

A2D, A2K/A6D, A6K

600VAC

70-600

200

HSRK

250VDC

0-600

100

A2D

UL
248-4

248-8
248-9
248-10

248-12

600VDC

0-600

100

A6D

250/600VAC

0-600

200

TR/TRS

300/600VDC

0-30/35-400

20

TRS-RDC

300/600VAC

0-1200/0-800

200

A3T/A6T

160/300VDC

0-1200

50/100

A3T/A6T

130-4000VAC

0-2000

Up to 300

See Section D

248-13
248-14

32-350VAC

0-30

Up to 10

See Section C

125/250VAC

0-30

0.2-10

TRM, OTM, GFN

500/600VAC

0-30

10,100

ATQ, ATM, SBS

125VAC

0-30

10

See Section G

250VAC

1-500kcmil Cu or Al

200

2CL

248-12
248-15

248-14
248-11

600VAC

#2-1000kcmil Cu or Al

200

CP, CPH

248-1

Capacitor

600-5500VAC

25-300

Up to 200

A100C-A550C

Other

Welder

600VAC

100-600

200

A4BX

Other

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fuse Construction And Operation
The typical fuse consists of an element which is surrounded
by a filler and enclosed by the fuse body. The element is
welded or soldered to the fuse contacts (blades or ferrules).
The element is a calibrated conductor. Its configuration,
its mass, and the materials employed are selected to

BLADE

BODY

FILLER ELEMENT

achieve the desired electrical and thermal characteristics.
The element provides the current path through the fuse.
It generates heat at a rate that is dependent upon its
resistance and the load current.
The heat generated by the element is absorbed by the filler
and passed through the fuse body to the surrounding air.
A filler such as quartz sand provides effective heat transfer
and allows for the small element cross-section typical in
modern fuses. The effective heat transfer allows the fuse to
carry harmless overloads. The small element cross section
melts quickly under short circuit conditions. The filler also
aids fuse performance by absorbing arc energy when the
fuse clears an overload or short circuit.
When a sustained overload occurs, the element will
generate heat at a faster rate than the heat can be passed
to the filler. If the overload persists, the element will
reach its melting point and open. Increasing the applied
current will heat the element faster and cause the fuse
to open sooner. Thus fuses have an inverse time current
characteristic, i.e. the greater the overcurrent the less time
required for the fuse to open the circuit.
This characteristic is desirable because it parallels the
characteristics of conductors, motors, transformers and
other electrical apparatus. These components can carry low
level overloads for relatively long times without damage.
However, under high current conditions damage can occur
quickly. Because of its inverse time current characteristic, a
properly applied fuse can provide effective protection over a
broad current range, from low level overloads to high level

P

short circuits.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P5

How To Read A Time-Current Curve
A time-current characteristic curve, for any specified fuse,

AJT	

is displayed as a continuous line representing the average
melting time in seconds for a range of overcurrent conditions.

Time Delay / Class J

Melting Time -Current Data
1-600 Amperes, 600 Volts AC

The melting time is considered nominal unless noted
otherwise. Several curves are traditionally shown on one
sheet to represent a family of fuses. The family shown here
is the Time Delay Class J AJT Amp-trap 2000 fuse.
Information can be accessed from these curves in
several ways:
• If a fuse has been selected, the designer can use the
curve for that fuse to check its opening time versus a given
overcurrent. Example: Using the 30 ampere fuse curve,
what is the fuse opening time in seconds at a current of 160
amperes? At the bottom of the sheet (Current in Amperes)
the point where it intersects the 30A curve (Pt. B). Then
follow that line to the left edge (Time in Seconds) and read
10 seconds. (Pt. C). This tells us that the AJT30 will open in
10 seconds on a current of 160 amperes.
• Likewise, for the same fuse we might want to know what
current will open the fuse in 0.1 second. On the vertical axis

Time in Seconds

find 160 amperes (Pt. A) and follow that line straight up to

(Time in Seconds) find 0.1 second (Pt. D) and follow that
line to the right until it intersects the 30A curve (Pt. E). Then
follow that line straight down to the horizontal axis (Current
in Amperes) and read 320 amperes (Pt. F). This shows that
the AJT30 requires an overcurrent of 320 amperes to open
in 0.1 second.
• The curves can be used in other ways by the designer.
For example, if a family has been chosen (i.e. Time Delay

Current in Amperes

Class J AJT) and an opening time of approximately 1
second is required at 3000 amperes, what fuse in the family
best meets this need? Find the 3000 ampere line on the
horizontal axis (Pt. G) and follow it up to the 1 second line
(Pt. H). The nearest curve to the right is the AJT400. If the
point is not near a curve shown, other intermediate curves
are available from the factory.
Sometimes the fuse family or type has not been chosen, so
a design requirement can be presented to several family
characteristic curves. One fuse type will emerge as a good
choice. Voltage rating, interrupting rating, physical size, time
delay, etc. are all considerations in the final choice.

P6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Low Voltage Fuses For Motor Protection
Code Requirements

The NEC or CEC requires that motor branch circuits be
protected against overloads and short circuits. Overload
protection may be provided by fuses, overload relays or
motor thermal protectors. Short circuit protection may be
provided by fuses or circuit breakers.

Disconnect

Fuse

Overload Protection

The NEC or CEC allows fuses to be used as the sole
means of overload protection for motor branch circuits. This
approach is often practical with small single phase motors.
If the fuse is the sole means of protection, the fuse ampere
rating must not exceed the values shown in Table 1.

Contactor

Overload Relay

Most integral horsepower 3 phase motors are controlled by
a motor starter which includes an overload relay. Since the
overload relay provides overload protection for the motor
branch circuit, the fuses may be sized for short
circuit protection.
The motor branch circuit fuses may be sized as large as
shown in Table 2 when an overload relay or motor thermal
protector is included in the branch circuit. Time delay fuse
ratings may be increased to 225% and non-time delay fuse
ratings to 400% (300% if over 600 amperes) if the ratings
shown in Table 2 will not carry motor starting current.
Some manufacturers’ motor starters may not be adequately
protected by the maximum fuse sizing shown in Table 2. If
this is the case, the starter manufacturer is required by UL
508 to label the starter with a maximum permissible fuse
size. If so labeled, this maximum value is not be exceeded.
Where the percentages shown in Table 2 do not correspond
to standard fuse ratings the next larger fuse rating may be
used. Standard fuse ratings in amperes:
15	20	25	30	35	 40	45	50
60	70	80	90	100	110	125	
150
175	200	225	250	300	 350	400	450
500	600	700	800	1000	1200	
1600	
2000
2500	3000	4000	5000	6000

Fuse Selection Guidelines

Motor Branch Circuit
Table 1- Maximum Fuse Rating for
Overload Protection
Motor Service Factor

Motor Full Load

Service factor of 1.15 or greater

125

Marked temperature rise not
Exceeding 40°C
All Others
* These percentages are not to be exceeded.

Table 2- Maximum Fuse Rating for Short
Circuit Protection
Fuse Rating as %*
Motor Full Load*
Fuse Type

Type of Motor

Non-Time
All Single-phase AC motors

Which Fuse Class?

rotor:

The Class J time delay fuse (AJT) provides advantages
over the RK5 and RK1 fuses. Class J fuses provide a higher
degree of current limitation than the RK’s. This reduced
fault current will reduce arc faults in cases of an arc flash
incident.

125
115

What fuse type and ampere rating is best for a given
application? The answer depends upon the application and
objective to be met. Here are some suggestions.
UL Classes RK5, RK1, and J are the most popular. The
Class RK5 ( Tri-onic®) is the least expensive. The Class
RK1 (Amp-trap®) is used where a higher degree of current
limitation is required for improved component protection or
system coordination. The RK5 and RK1 are dimensionally
interchangeable.

Fuse Rating as %*

or Marked Temperature Rise

Delay

Time Delay

300

175

Other than Design E

300

175

Design E

300

175

Synchronous

300

175

Wound rotor

150

150

Direct-current (constant voltage)

150

150

AC polyphase motors other than woundSquirrel Cage

P

Short Circuit Protection

Motor

* The non-time delay ratings apply to all class CC fuses.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P7

Low Voltage Fuses For Motor Protection
The Class J fuse is also about half the physical size of the
RK5 and RK1 reducing panel space and saving money.

fuses are more current limiting than the RK5 and have less
short time current carrying capability.

Time Delay vs. Non-Time Delay

Sizing time delay fuses between 125% and 150% of motor full
load current provides advantages. The fuse will coordinate with
NEMA Class 20 overload relays. Nuisance fuse opening will
virtually be eliminated and effective short circuit protection will
be maintained.

Time delay fuses are the most useful fuses for motor branch
circuit application. A time delay fuse can be sized closer
to motor full load current, providing a degree of overload
protection, better short circuit protection, and possible use of
a smaller disconnect switch.

Protecting IEC Style Motor Starters

What Ampere Rating?

The new IEC European style motor starters and contactors are
popular but they present different problems in protection. These
devices represent substantial savings in space and cost but they
have a lower withstand capability than their NEMA counterparts.

The selection of fuse ampere rating is a matter of experience
and personal preference. Some prefer to size time delay fuses
at 125% of motor full load amperes. This sizing will provide a
degree of overload protection for motors with a service factor
of 1.15. Sizing fuses at 125% of motor nameplate amperes in
some applications may result in nuisance fuse openings. Time
delay fuses sized at 125% may open at motor locked rotor
current before some NEMA Class 20 overload relays operate.
Nuisance fuse openings may result if Class RK1 or Class J
fuses are sized at 125% of motor full load current. These

In order to achieve the same level of protection for IEC style
devices that we expect for NEMA devices, the AJT Class J
Time Delay fuse is the best choice, sized at 1.25 to 1.50 times
motor full load amperes. Also, the AJT has the advantage of
being half the size of RK5 and RK1 fuses and thereby fits the
trim IEC package.

Single Phase Motor Fuse Selection UL Classes RK1, RK5, J & CC
Motor

Full Load

HP

Current

Recommended Ampere Rating
Motor Acceleration Times
Minimum

115V

Typical

Heavy Load

Minimum

Typical

RK5 and RK1 TR/A2D

Heavy Load

Minimum

Typical

J-AJT

Heavy Load

CC-ATDR

1/6

4.4

5 6/10

6 1/4

8

5 6/10

6 1/4

8

12

15

17 1/2

1/4

5.8

7

8

12

8

8

12

12

17 1/2

20

1/3

7.2

9

12

15

9

12

15

17 1/2

25

25

1/2

9.8

12

15

17

12

15

17 1/2

20

30

3/4

13.8

17 1/2

20

25

17 1/2

20

25

30

-

-

1

16

20

25

30

20

25

30

-

-

-

1 1/2

20

25

30

35

25

30

35

-

-

-

2

24

30

35

40

30

35

40

-

-

-

3

34

45

50

60

45

50

60

-

-

-

5

56

70

80

100

70

80

100

-

-

-

7 1/2

80

100

125

150

100

125

150

-

-

-

10

100

125

150

175

125

150

175

-

-

-

1/6

2.2

2 8/10

3 1/2

4

3

3 1/2

4

5

7

10

1/4

2.9

3 1/2

4 1/2

5 6/10

3 1/2

4 1/2

5 6/10

6

9

10

1/3

3.6

4 1/2

5 6/10

7

4 1/2

5 6/10

7

8

12

15

1/2

4.9

6 1/4

7

9

6 1/4

7

9

12

15

17 1/2

230V

RK5 and RK1 TR/A2D

J-AJT

CC-ATDR

3/4

6.9

9

12

15

9

12

15

15

20

25

1

8

10

12

15

10

12

15

20

25

30

1 1/2

10

12

15

17 1/2

12

15

17 1/2

20

30

-

2

12

15

17 1/2

25

15

17 1/2

25

25

-

-

3

17

20

25

30

20

25

30

-

-

-

5

28

35

40

50

35

40

50

-

-

-

7 1/2

40

50

60

70

50

60

70

-

-

-

10

50

60

80

90

60

80

90

-

-

-

Minimum - This sizing is recommended if motor acceleration times do not exceed 2 seconds. Minimum sizing with RK1, RK5, and Class J fuses will provide
overload relay back up protection but may not coordinate with some NEMA Class 20 overload relays. Minimum sizing is generally not heavy enough for motors
with code letter G or higher.
Typical - Suggested for most applications. Will coordinate with NEMA Class 20 overload relays. Suitable for motor acceleration times up to 5 seconds.
Heavy Load - Maximum fuse size in accordance with Table 2. If this fuse size is not sufficient to start the load, RK1, RK5, and J time delay fuse size may be
increased to a maximum of 225% of full load amperes. Class CC fuses may be increased to 400% of full load amperes. The Heavy Load column should be
used for Design E and high efficiency Design B motor fuse sizing.

P8

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Low Voltage Fuses For Motor Protection
Three Phase Motor Fuse Selection UL Classes RK5, RK1, J & CC
Full Load

HP

Current

Recommended Ampere Rating
Motor Acceleration Times
Minimum

208V

Typical

Heavy Load

Minimum

Typical

RK5 and RK1 TR/A2D

Heavy Load

Minimum

Typical

J-AJT

Heavy Load

CC-ATDR

1/2

2.4

3

3 1/2

4 1/2

3

3 1/2

4 1/2

5

8

3/4

3.5

4 1/2

5

6 1/4

4 1/2

5

6 1/4

8

10

15

1

4.6

5 6/10

7

9

6

7

9

10

15

17 1/2

1 1/2

6.6

8

10

12

8

10

12

15

20

25

2

7.5

9

12

15

9

12

15

17 1/2

25

30

3

10.6

15

15

20

15

15

20

25

30

-

5

16.8

20

25

30

20

25

30

-

-

-

7 1/2

24.2

30

35

45

30

35

45

-

-

-

10

30.8

40

50

60

40

50

60

-

-

-

15

46.2

60

70

90

60

70

90

-

-

-

20

60

75

90

110

80

90

110

-

-

-

25

75

90

110

150

90

110

150

-

-

-

30

88

110

150

175

110

150

175

-

-

-

40

114

150

175

200

150

175

200

-

-

-

50

143

175

225

300

175

225

300

-

-

-

60

169

200

250

300

200

250

300

-

-

-

75

211

250

350

400

250

350

400

-

-

-

100

273

350

400

500

350

400

500

-

-

-

125

343

450

500

600

450

500

600

-

-

-

150

396

500

600

-

500

600

-

-

-

230V

RK5 and RK1 TR/A2D

J-AJT

10

CC-ATDR

1/2

2.2

2 8/10

3 1/2

4

3

3 1/2

4

5

7

10

3/4

3.2

4

5

6

4

5

6

8

10

12

1

4.2

5

6 1/4

8

5

6 1/4

8

10

12

15

1 1/2

6

8

9

12

8

9

12

15

17 1/2

20

2

6.8

8

10

12

8

10

12

15

20

25

3

9.6

12

15

17 1/2

12

15

17 1/2

20

30

-

5

15.2

20

25

30

20

25

30

-

-

-

7 1/2

22

30

35

40

30

35

40

-

-

-

10

28

35

40

50

35

40

50

-

-

-

15

42

50

60

80

50

60

80

-

-

-

20

54

70

80

100

70

80

100

-

-

-

25

68

80

100

125

80

100

125

-

-

-

30

80

100

125

150

100

125

150

-

-

-

40

104

125

150

200

125

150

200

-

-

-

50

130

175

200

250

175

200

250

-

-

-

60

154

200

225

300

200

225

300

-

-

-

75

192

250

300

350

250

300

350

-

-

-

100

248

300

350

450

300

350

450

-

-

-

125

312

400

450

600

400

450

600

-

-

-

150

360

450

500

600

450

500

600

-

-

-

200

480

600

-

-

600

-

-

-

-

-

P

Motor

Minimum - This sizing is recommended if motor acceleration times do not exceed 2 seconds. Minimum sizing with RK1, RK5, and Class J fuses will provide
overload relay back up protection but may not coordinate with some NEMA Class 20 overload relays. Minimum sizing is generally not heavy enough for
motors with code letter G or higher.
Typical - Suggested for most applications. Will coordinate with NEMA Class 20 overload relays. Suitable for motor acceleration times up to 5 seconds.
Heavy Load - Maximum fuse size in accordance with Table 2. If this fuse size is not sufficient to start the load, RK1, RK5, and J time delay fuse size may be
increased to a maximum of 225% of full load amperes. Class CC fuses may be increased to 400% of full load amperes. The Heavy Load column should be
used for Design E and high efficiency Design B motor fuse sizing.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P9

Low Voltage Fuses For Motor Protection
Three Phase Motor Fuse Selection UL Classes RK5, RK1, J & CC
Recommended Ampere Rating
Motor

Full Load

HP

Current

Motor Acceleration Times
Minimum

380V

Typical

Heavy
Load

Minimum

RK5 and RK1 TRS / A6D

Typical

Heavy
Load

Minimum

J-AJT

Typical

Heavy
Load

CC-ATDR

1/2

1.3

1 6/10

2

2 1/2

1 6/10

2

2 8/10

3

4

6

3/4

1.7

2 1/4

2 8/10

3

2 1/2

2 8/10

3 1/2

4

5 6/10

6 1/4

1

2.2

2 8/10

3 1/2

4 1/2

3

3 1/2

4

5

8

10

1 1/2

3.6

4 1/2

5 6/10

7

4 1/2

5 6/10

7

8

12

15

2

4.1

5

6

8

5

6

8

9

12

15

3

5.8

7

8

12

8

8

12

12

17 1/2

20

5

9.2

12

15

17 1/2

12

15

17 1/2

20

30

-

7 1/2

13.3

15

20

25

17 1/2

20

25

30

-

-

10

17

20

25

30

20

25

30

-

-

-

15

25

30

35

45

30

35

45

-

-

-

20

33

40

50

60

40

50

60

-

-

-

25

41

50

60

75

50

60

80

-

-

-

30

48

60

70

90

60

80

90

-

-

-

40

68

80

100

125

80

100

125

-

-

-

50

79

100

125

150

100

125

150

-

-

-

60

93

110

150

175

110

150

175

-

-

-

75

116

150

175

225

150

175

225

-

-

-

100

150

175

225

300

175

225

300

-

-

-

125

189

250

300

350

250

300

350

-

-

-

150

218

300

350

400

300

350

400

-

-

-

200

291

350

450

600

350

450

600

-

-

-

Minimum - This sizing is recommended if motor acceleration times do not exceed 2 seconds. Minimum sizing with RK1, RK5, and Class J fuses will provide
overload relay back up protection but may not coordinate with some NEMA Class 20 overload relays. Minimum sizing is generally not heavy enough for
motors with code letter G or higher.
Typical - Suggested for most applications. Will coordinate with NEMA Class 20 overload relays. Suitable for motor acceleration times up to 5 seconds.
Heavy Load - Maximum fuse size in accordance with Table 2. If this fuse size is not sufficient to start the load, RK1, RK5, and J time delay fuse size may
be increased to a maximum of 225% of full load amperes. Class CC fuses may be increased to 400% of full load amperes. The Heavy Load column should
be used for Design E and high efficiency Design B motor fuse sizing.

P10

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Low Voltage Fuses For Motor Protection
Three Phase Motor Fuse Selection UL Classes RK5, RK1, J, CC and L
Motor

Full Load

HP

Current

Recommended Ampere Rating
Motor Acceleration Times
Minimum

460V

Typical

Heavy Load

Minimum

Typical

RK5 and RK1 TRS / A6D

Heavy Load

Minimum

Typical

J-AJT

Heavy Load

CC-ATDR

1/2

1.1

1 4/10

1 6/10

2

1 1/2

1 6/10

2

3

3 1/2

6

3/4

1.6

2

2 1/4

2 8/10

2

2 1/4

2 8/10

3 1/2

5

6 1/4

1

2.1

2 1/2

3 2/10

4

2 1/2

3 2/10

4

5

6 1/4

8

1 1/2

3

3 1/2

4 1/2

5 6/10

3 1/2

4 1/2

5 6/10

6

9

12

2

3.4

4

5

6

4

5

6

8

10

15

3

4.8

5 6/10

7

9

6

7

9

12

15

17 1/2

5

7.6

10

12

15

10

12

15

17 1/2

25

30

7 1/2

11

15

17 1/2

20

15

17 1/2

20

25

30

-

10

14

17 1/2

20

25

17 1/2

20

25

30

-

-

15

21

25

30

40

25

30

40

-

-

-

20

27

35

40

50

35

40

50

-

-

-

25

34

45

50

60

40

50

60

-

-

-

30

40

50

60

70

50

60

70

-

-

-

40

52

70

80

100

70

80

100

-

-

-

50

65

80

100

125

80

100

125

-

-

-

60

77

100

125

150

100

125

150

-

-

-

75

96

125

150

175

125

150

175

-

-

-

100

124

175

200

225

175

200

225

-

-

-

125

156

200

225

300

200

225

300

-

-

-

150

180

225

250

350

225

250

350

-

-

-

200

240

300

350

450

300

350

450

-

-

-

250

302

400

450

600

400

450

600

-

-

-

300

361

450

600

-

450

600

-

-

-

-

Motor HP

Full Load
Current

Class L A4BT

300

360

-

601

800

400

477

-

800

1200

500

590

-

1000

1600

P

Minimum - This sizing is recommended if motor acceleration times do not exceed 2 seconds. Minimum sizing with RK1, RK5, and Class J fuses will
provide overload relay back up protection but may not coordinate with some NEMA Class 20 overload relays. Minimum sizing is generally not heavy
enough for motors with code letter G or higher.
Typical - Suggested for most applications. Will coordinate with NEMA Class 20 overload relays. Suitable for motor acceleration times up to 5 seconds.
Heavy Load - Maximum fuse size in accordance with Table 2. If this fuse size is not sufficient to start the load, RK1, RK5, and J time delay fuse size
may be increased to a maximum of 225% of full load amperes. Class CC fuses may be increased to 400% of full load amperes. The Heavy Load column
should be used for Design E and high efficiency Design B motor fuse sizing.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P11

Low Voltage Fuses For Motor Protection
Three Phase Motor Fuse Selection UL Classes RK5, RK1, J, CC and L
Recommended Ampere Rating
Motor

Full Load

HP

Current

575V

Motor Acceleration Times
Minimum

Typical

Heavy
Load

RK5 and RK1 TRS / A6D

Minimum

Typical

Heavy
Load

J-AJT

Minimum

Typical

Heavy
Load

CC-ATDR

1/2

0.9

1 1/8

1 4/10

1 6/10

1 1/4

1 1/2

1 6/10

2 1/2

2 8/10

3 1/2

3/4

1.3

1 6/10

2

2 1/2

1 6/10

2

2 8/10

3

4

6

1

1.7

2 1/4

2 1/2

3

2 1/4

2 8/10

3 1/2

4

5 6/10

6 1/4

1 1/2

2.4

3

3 1/2

4 1/2

3

3 1/2

4 1/2

5

8

10

2

2.7

3 2/10

4

5

3 2/10

4

5

6

8

10

3

3.9

5

6

7

5

6

7

9

12

15

5

6.1

8

9

12

8

10

12

15

17 1/2

20

7 1/2

9

12

15

17 1/2

12

15

17 1/2

20

30

-

10

11

15

17 1/2

20

15

17 1/2

20

25

30

-

15

17

20

25

30

20

25

30

-

-

-

20

22

30

35

40

30

35

40

-

-

-

25

27

35

40

50

35

40

50

-

-

-

30

32

40

50

60

40

50

60

-

-

-

40

41

50

60

75

50

60

80

-

-

-

50

52

70

80

100

70

80

100

-

-

-

60

62

75

90

110

80

90

110

-

-

-

75

77

100

125

150

100

125

150

-

-

-

100

99

125

150

175

125

150

175

-

-

-

125

125

175

200

225

175

200

225

-

-

-

150

144

175

225

300

175

225

300

-

-

-

200

192

250

300

350

250

300

350

-

-

-

250

240

300

350

500

300

350

500

-

-

-

289

350

450

600

350

450

600

-

-

-

300
Motor HP

Full Load

Class L A4BT

Current

400

382

--

800

1100

500

472

--

1000

1400

Minimum - This sizing is recommended if motor acceleration times do not exceed 2 seconds. Minimum sizing with RK1, RK5, and Class J fuses will
provide overload relay back up protection but may not coordinate with some NEMA Class 20 overload relays. Minimum sizing is generally not heavy
enough for motors with code letter G or higher.
Typical - Suggested for most applications. Will coordinate with NEMA Class 20 overload relays. Suitable for motor acceleration times up to 5 seconds.
Heavy Load - Maximum fuse size in accordance with Table 2. If this fuse size is not sufficient to start the load, RK1, RK5, and J time delay fuse size
may be increased to a maximum of 225% of full load amperes. Class CC fuses may be increased to 400% of full load amperes. The Heavy Load column
should be used for Design E and high efficiency Design B motor fuse sizing.

P12

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Medium Voltage Motor Protection
Fuse Application Guidelines

The guidelines for applying R-Rated fuses are significantly
different from those applying to low voltage motor fuses.
This is because R-Rated fuses are back-up fuses which are
intended to provide short circuit protection only for medium
voltage starters and motors.

Fuse/Overload Relay Crossover Point

Time

An R-Rated fuse is not designed to protect itself or other
circuit components against long term overloads. This is
why these fuses are given an R rating, and not an ampere
rating. An R-Rated fuse will safely interrupt any current
between its minimum interrupting rating and its maximum
interrupting rating. The minimum interrupting rating is
verified during UL tests for UL component recognition.
R-Rated fuses must be applied in combination with
an overload relay and a contactor. The time current
characteristics of the fuse and overload relay should be
matched so that the contactor interrupts currents below the
fuse’s minimum interrupting rating while the fuse interrupts
fault currents, thus easing duty on the contactor and
extending the interrupting ability of the controller.
A medium voltage starter is usually engineered for a
specific motor and application. For this reason the starter
manufacturer selects the proper fuse R rating and provides
the fuses as part of the starter package. Unless the user
has good reason, no deviation should be made from the R
rating recommended by the starter manufacturer. If the user
has an existing starter which is to be applied to a new or
different motor, the application should be reviewed with the
starter manufacturer. Recalibration of the overload relay(s)
or fuses of a different R rating may be required.
Properly sized R-Rated fuses should provide a service
life approaching that of the contactor. If fuse openings are
experienced with no faults present, the fuses, overload relay
or both may be improperly sized. The table in this section
is offered as a guideline and shows the maximum motor
full load current appropriate for a given R rating. In addition
to this table it is advisable to compare the fuse minimum
melt time-current curve and the nominal time-current
characteristic curve for the overload relay. These curves
should intersect at (B) no less than 120% of motor locked
rotor current (see figure). This will assure that the contactor
will open before the fuse during locked rotor conditions.

Current
Where B ≥ 1.2 x locked rotor amperes

Motor Full Load Currents for R-Rated Fuses*
Max. Motor Full-Load Current For
Full Voltage Start - Amperes

Fuse R Rating

10 sec. start

3 sec. start

2R

28

32

3R

40

45

4R

55

65

5R

65

75

6R

80

95

9R

125

140

12R

165

190

18R

250

280

24R

330

360

36R

500

550

*Note: Always round up to the next larger R rating.

The 10 or 3 Second Start

P

The 10 or 3 second start listed in the table is a start during
which the motor accelerates from standstill to rated speed
in 10 (or 3) seconds or less. For reduced voltage starting,
motor starting current should not exceed 75% of the
fuse minimum melt current for the required motor
acceleration time.
Consult the factory for application assistance for ratings
above 36R.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P13

Transformer Protection
This section summarizes transformer overcurrent protection
as required by the National Electrical Code (NEC) and
Canadian Electric Code.

Secondary Fuses

Transformers - Primary 600 Volts or Less

Selecting fuses for the secondary is simple once rated
secondary current is known. Fuses are sized at 125% of
secondary FLA or the next higher rating; or at maximum 167%
of secondary FLA, see Table 2 for rules. The preferred sizing
is 125% of rated secondary current Isec or next higher fuse
rating. To determine Isec, first determine transformer rating (VA
or kVA), secondary voltage (Vsec) and use formulas below.

Table 1- Primary Fuse Only

1. Single Phase : Isec = Transformer VA	
			
Vsec
	
or
Transformer kVA x 1000	
		
			
Vsec

If secondary fuse protection is not provided, primary fuses
are to be selected according to Table 1. If both primary and
secondary fuses are used, they are to be selected according
to Table 2.

Transformer Primary Amperes

Maximum Primary Fuse % Rating

9 or more

125*

2 to less than 9

167

less than 2

300

Table 2- Primary & Secondary Fuses
Transformer Secondary

Maximum Primary Fuse % Rating

Amperes

Primary Fuse

Secondary Fuse

9 or more

250

125*

less than 9

250

167

* If 125% does not correspond to a standard ampere rating, the next
higher standard rating shall be permitted.

Transformer Magnetizing Inrush Currents
When voltage is switched on to energize a transformer, the
transformer core normally saturates. This results in a large
inrush current which is greatest during the first half cycle
(approximately .01 second) and becomes progressively less
severe over the next several cycles (approximately
1 second) until the transformer reaches its normal
magnetizing current.

To accommodate this inrush current, fuses are often
selected which have time-current withstand values of at
least 12 times transformer primary rated current for .1
second and 25 timess for .01 second. Recommended
primary fuses for popular, low-voltage 3-phase transformers
are shown on the next page. Some small dry-type
transformers may have substantially greater inrush currents.
For these applications, the fuse may have to be selected to
withstand 45 times transformer primary rated current for .01
second.

2. Three Phase : Isec = Transformer VA	
		
1.73 x Vsec
	
		
or
Transformer kVA x 1000	
			
1.73 x Vsec
When Isec is determined, multiply it by 1.25 and choose that
fuse rating or next higher rating. [ Isec x 1.25 = Fuse Rating ]

Transformers - Primary Over 600 Volts

If in unsupervised locations, fuses are to be selected according
to Table 3. Where the required fuse rating does not correspond
to a standard ampere rating, the next higher standard rating
shall be permitted. In supervised locations,fuses are to be
selected according to Table 4.

Table 3- Unsupervised Locations
Transformer
Secondary Amperes
6 or less
More than 6 & not more
then 10

Maximum % Rating
Secondary Fuse

Primary
Fuse

Over 600V

600V or Less

300*

250*

125*

300*

225*

125*

Table 4- Supervised Locations
Maximum % Rating

Transformer
Rated %

Primary

Impedance

Fuse

Over 600V

600V or Less

All

250*

-

-

6 or less

300

250

250

300

225

250

More than 6 & not more
then 10

Secondary Fuse

* Where fuse sizes do not correspond to a standard ampere rating, the next
higher standard rating shall be permitted.

P14

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Primary Fuses For 3-Phase LV Transformers
Recommended Primary Fuses for 240 Volt, Three Phase Transformers
Transformer
Rating kVA

240 Volt Primary
Primary Fuse Rating

Primary Full
Load Amps

TR-R

A2D-R*

A4BT*

A4BY*

A4BQ*

3

7.2

9

15

-

-

-

5

12

15

25

-

-

-

7-1/2

18

25

40

-

-

-

9

22

30

45

-

-

-

15

36

45

60

-

-

-

30

72

90

150

-

-

-

45

108

150

225

-

-

-

75

180

225

400

-

-

-

100

241

300

450

-

-

-

112-1/2

271

350

500

-

-

-

150

361

450

600

-

-

-

225

541

600

-

800

900

1200

300

722

-

-

1200

1200

1600

500

1203

-

-

1800

2000

2500

750

1804

-

-

-

3000

4000

1000

2406

-

-

-

5000

5000

1500

3608

-

-

-

6000

-

Recommended Primary Fuses for 480 & 600 Volt, Three Phase Transformers
480 Volt Primary

Rating kVA

Full
Load

TRS-R

Amps

AJT* or
A6D-R*

Primary Fuse Rating

Primary
Full

A4BT*

A4BY*

A4BQ*

Load

TRS-R

Amps

AJT* or
A6D-R*

A4BT*

A4BY*

A4BQ*

3

3.6

4-1/2

6

-

-

-

2.9

4

5

-

-

-

5

6.0

8

12

-

-

-

4.8

6

10

-

-

-

7-1/2

9.0

12

15

-

-

-

7.2

9

15

-

-

-

9

11

15

25

-

-

-

9.0

12

17-1/2

-

-

-

15

18

25

35

-

-

-

14

20

25

-

-

-

30

36

45

60

-

-

-

29

35

45

-

-

-

45

54

70

100

-

-

-

43

60

80

-

-

-

75

90

125

175

-

-

-

72

90

150

-

-

-

100

120

150

225

-

-

-

96

125

200

-

-

-

112-1/2

135

175

300

-

-

-

108

150

225

-

-

-

150

180

225

400

-

-

-

144

200

300

-

-

-

225

271

350

500

-

-

-

217

300

450

-

-

-

300

361

450

600

-

-

-

289

350

500

-

-

-

500

601

-

-

1000

1000

1200

481

600

-

700

900

1000

750

902

-

-

1400

1600

2000

722

-

-

1200

1400

1600

1000

1203

-

-

1800

2000

2500

962

-

-

1600

1800

2000

1500

1804

-

-

-

3000

4000

1443

-

-

2000

2500

3000

2000

2406

-

-

-

4000

5000

1925

-

-

-

4000

4000

2500

3007

-

-

-

5000

6000

2406

-

-

-

5000

5000

P

Transformer

600 Volt Primary

Primary Fuse Rating

Primary

*When using these fuses, the secondary of the transformer must be fused to comply with the Code.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P15

Secondary Fuses for LV Transformers
TRANSFORMER
RATING

SECONDARY FULL LOAD
(VAC) 3-PHASE

AMPS AT RATED VOLTAGE
FOR 120V

SECONDARY FUSE RATING

FOR 240V

SECONDARY FUSE RATING

FOR 480V

SECONDARY FUSE RATING

FOR 600V

SECONDARY FUSE RATING

*A2DA4BQ

-

-

A4BY

-

-

-

-

A4BT

45

25

15

12

8

5

-

-

-

-

-

-

-

A4BQ

-

-

-

-

-

-

-

A4BY

-

-

-

-

-

-

-

60

35

20

12

9

6

4

A4BT AJT, or

-

-

-

-

-

-

-

-

-

A4BQ

-

-

-

-

-

-

-

-

-

-

-

A4BY

-

-

-

-

-

-

-

-

-

-

-

-

-

A4BT

*A6D-R,

-

-

-

70

90

-

-

-

*A6D-R,

-

-

-

125

-

-

900

R, AJT,

9

-

-

-

-

150

-

-

1200

*A2D-R,

15

-

-

-

200

-

900

2000

1500

1000

750

500

300

225

150

112.5

100

75

45

30

15

9

7.5

5

3

14451

12042

9634

7225

4817

3613

2408

1445

1084

723

542

482

361

217

145

72

43

36

9032

7225

6021

4817

3613

2408

1806

1204

723

542

361

271

241

181

108

72

36

22

4516

3613

3011

2408

1806

1204

903

602

361

271

181

135

120

90

54

36

18

3613

2890

2408

1927

1445

963

723

482

289

217

145

108

96

72

43

29

-

-

-

-

-

-

-

-

-

-

600

450

-

-

-

6000

4500

3000

1800

1350

900

700

-

-

-

-

6000

4500

3000

1800

1350

900

700

-

-

-

2000

1400

900

-

-

-

-

-

-

-

-

-

6000

4500

3000

2200

1500

900

-

6000

4500

3000

2200

1500

-

-

-

-

-

-

6000

5000

4000

3000

4000

*TR-R

2500

18064

-

*TRS-R

-

25

-

-

-

-

300

-

1200

AJT, or

-

30

-

-

-

400

900

-

2000

3000

4817

3750

6021

*TRS-R

-

-

45

-

-

-

-

600

1200

2000

-

or

-

-

90

-

-

-

-

2500

-

A4BT

-

-

150

125

-

-

750

-

2000

3000

-

A4BQ A4BY

-

-

150

-

-

1000

2500

3500

AJT, or

20
-

-

-

-

175

-

750

1500

-

3000

5000

600

30
-

-

-

-

250

-

1000

-

3500

480

3
45
-

-

-

-

-

350

750

1500

-

-

5000

240

4
5
50
-

225

-

-

-

450

1000

2500

-

-

-

120

7
6
7
90

-

-

300

-

-

700

-

1500

3000

-

-

6000

12042

(kVA)

14
12
9
9
200

-

-

350

-

700

900

-

5000

6000

24085

*TR-R

24
18
11
14
300

-

-

700

450

700

900

1500

-

2500

6000

-

5000

*Use A2D(Amp)R, A6D(Amp)R, TR(Amp)R, or TRS(Amp)R.

www.barr-thorp.com

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

P16

Primary Fuses For MV 3-Phase Power Transformers
3 Phase 2400 Volt Typical Primary Fuse Sizing Chart
Transformer

Full Load

2 “ Ferrule mounting

3 “ Ferrule mounting (single and double)

Bolt on

Clip Lock

Rating kVA2

Amperes

9F60 EJ “C”

9F60 EJO “C”

A055F

9F60 EJ “D”

9F60 EJO “D”

A055F

A055B

A055C

9

2.2

9F60CCB005 *

9F60DJB005

A055F1C0R0-5E

-

-

-

-

-

15

3.6

9F60CCB010 *

9F60DJB010

A055F1C0R0-7E

-

-

-

-

-

30

7.2

9F60CCB020 *

9F60DJB020

A055F1C0R0-10E

-

-

A055F1D0R0-10E

A055B1DAR0-10E

A055C1D0R0-10E

45

11

9F60CCB025 *

9F60DJB025

A055F1C0R0-15E

-

-

A055F1D0R0-15E

A055B1DAR0-15E

A055C1D0R0-15E

75

18

-

-

A055F1C0R0-25E

9F60ECB030

9F60FJB030

A055F1D0R0-25E

A055B1DAR0-25E

A055C1D0R0-25E

112.5

27

-

-

A055F1C0R0-40E

9F60ECB050

9F60FJB050

A055F1D0R0-40E

A055B1DAR0-40E

A055C1D0R0-40E

150

36

-

-

A055F1C0R0-50E

9F60ECB065

9F60FJB065

A055F1D0R0-50E

A055B1DAR0-50E

A055C1D0R0-50E

225

54

-

-

-

9F60ECB100

9F60FJB100

A055F1D0R0-80E

A055B1DAR0-80E

A055C1D0R0-80E

300

72

-

-

-

9F60GCB125

9F60HJB125

A055F1D0R0-100E

A055B1DAR0-100E

A055C1D0R0-100E

500

120

-

-

-

9F60GCB200

9F60HJB200

A055F1D0R0-200E

A055B1DAR0-200E

A055C1D0R0-200E

750

181

-

-

-

-

-

A055F2D0R0-250E

A055B2DAR0-250E

A055C1D0R0-250E

1000

241

-

-

-

-

-

A055F2D0R0-400E

A055B2DAR0-400E

A055C1D0R0-400E

1500

361

-

-

-

-

-

-

A055B2D0R0-500E

A055C2D0R0-500E

2000

482

-

-

-

-

-

-

A055B2D0R0-600E

A055C2D0R0-600E

Fuses will carry transformer magnetizing inrush current of 25 times full load amperes for .01 second and 12 times full load current for .1 second
	2
EJO fuses can be used outdoors without an enclosure	
the self cooled rating of the transformer	
	* use CEB in place of CCB for 9” clip center fuses

3 Phase 4160 Volt Typical Primary Fuse Sizing Chart
Transformer
Rating kVA2

Full Load
Amperes

9
15

2 “ Ferrule mounting
9F60 EJO
9F60 EJ “C”
“C”

9F62 EJO
“C”

1.3

9F60CED005

9F60DJD005

2.1

9F60CED007

9F60DJD007

30

4.2

9F60CED015

45

6.3

75

3 “ Ferrule mounting (single and double)
A055F

9F60 EJO
“D”

9F62 EJO
“D”

-

A055F1C0R0-5E

-

-

A055F1C0R0-5E

-

9F60DJD015

-

A055F1C0R0-7E

9F60CED015

9F60DJD015

-

10

9F60CED025

9F60DJD025

112.5

16

-

150

21

225

Bolt on

Clip Lock

A055F

9F62 EJO
“DDDD”

A055B

A055C

-

-

-

-

-

-

-

-

-

-

-

-

A055F1D0R0-10E

-

A055B1DAR0-10E

A055C1D0R0-10E

A055F1C0R0-10E

-

-

A055F1D0R0-10E

-

A055B1DAR0-10E

A055C1D0R0-10E

9F62HCB025

A055F1C0R0-15E

-

-

A055F1D0R0-15E

-

A055B1DAR0-15E

A055C1D0R0-15E

-

9F62HCB030

A055F1C0R0-20E

9F60FJD040

-

A055F1D0R0-20E

-

A055B1DAR0-20E

A055C1D0R0-20E

-

-

9F62HCB040

A055F1C0R0-30E

9F60FJD040

-

A055F1D0R0-30E

-

A055B1DAR0-30E

A055C1D0R0-30E

31

-

-

9F62HCB050

A055F1C0R0-40E

9F60FJD065

-

A055F1D0R0-40E

-

A055B1DAR0-40E

A055C1D0R0-40E

300

42

-

-

-

A055F1C0R0-65E

9F60FJD080

9F62DCB080

A055F1D0R0-65E

-

A055B1DAR0-65E

A055C1D0R0-65E

500

69

-

-

-

-

9F60FJD100

9F62DCB100

A055F1D0R0-100E

-

A055B1DAR0-100E

A055C1D0R0-100E

750

104

-

-

-

-

9F60HJD150

9F62DCB150

A055F1D0R0-150E

-

A055B1DAR0-150E

A055C1D0R0-150E

1000

139

-

-

-

-

9F60HJD200

9F62DCB200

A055F1D0R0-200E

-

A055B1DAR0-200E

A055C1D0R0-200E

1500

208

-

-

-

-

-

9F62FCB300

A055F2D0R0-300E

-

A055B2DAR0-300E

A055C1D0R0-300E

2000

278

-

-

-

-

-

9F62FCB350

A055F2D0R0-400E

-

A055B2DAR0-400E

A055C1D0R0-400E

2500

347

-

-

-

-

-

-

-

9F62KCB500

A055B2D0R0-500E

A055C2D0R0-500E

3000

417

-

-

-

-

-

-

-

9F62KCB600

A055B2D0R0-600E

A055C2D0R0-600E

3750

520

-

-

-

-

-

-

-

9F62KCB700

A055B3D0R0-750E

-

4000

556

-

-

-

-

-

-

-

9F62KCB700

A055B3D0R0-750E

-

4500

625

-

-

-

-

-

-

-

9F62KCB800

A055B3D0R0-900E

-

5000

695

-

-

-

-

-

-

-

9F62KCB900

A055B3D0R0-900E

-

Examples:

1. A new installation has a 300kVA transformer with 4160V
primary. It is not fully loaded. What is the typical primary fuse
recommended?

4160V
Source

Load

A 65 rating (Mersen A055F1DORO-65E or equivalent) is correct.
Lower ratings may open when transformer is energized.

2. W
 hat is the normal fuse size recommended for a 1500kVA
transformer with 12,470V primary?

8320V
Source

P

Fuses will carry transformer magnetizing inrush current of 25 times full load amperes for .01 second and 12 times full load current for .1 second
EJO fuses can be used outdoors without an enclosure		2 the self cooled rating of the transformer

Load

For this application use a 100E rating A155F2DORO-100E
or equivalent which will allow normal overload operations of
transformer up to 133% of rating.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P17

Primary Fuses For MV 3-Phase Power Transformers
3 Phase 4800 Volt Typical Primary Fuse Sizing Chart
Transformer

Full Load

2 “ Ferrule mounting
9F60 EJ

9F60 EJO

9F62 EJO

3 “ Ferrule mounting (single and double)
9F60 EJO

9F62 EJO

Bolt on
9F62 EJO

Clip Lock

Rating kVA

Amperes

“C”

“C”

“C”

“D”

“D”

A055B

A055C

9

1.1

9F60CED005

9F60DJD005

-

-

-

-

-

-

-

-

15

1.8

9F60CED005

9F60DJD005

-

A055F1C0R0-5E

-

-

-

-

-

-

30

3.6

9F60CED010

9F60DJD010

-

A055F1C0R0-7E

-

-

-

-

-

-

45

5.4

9F60CED015

9F60DJD015

-

A055F1C0R0-10E

-

-

A055F1D0R0-10E

-

A055B1DAR0-10E

A055C1D0R0-10E

75

9.0

9F60CED020

9F60DJD020

9F62HCB025

A055F1C0R0-15E

-

-

A055F1D0R0-15E

-

A055B1DAR0-15E

A055C1D0R0-15E

112.5

14

9F60CED030

9F60DJD030

9F62HCB030

A055F1C0R0-20E

-

-

A055F1D0R0-20E

-

A055B1DAR0-20E

A055C1D0R0-20E

150

18

-

-

9F62HCB040

A055F1C0R0-25E

9F60FJD040

-

A055F1D0R0-25E

-

A055B1DAR0-25E

A055C1D0R0-25E

225

27

-

-

9F62HCB050

A055F1C0R0-40E

9F60FJD065

-

A055F1D0R0-40E

-

A055B1DAR0-40E

A055C1D0R0-40E

300

36

-

-

9F62HCB065

A055F1C0R0-50E

9F60FJD065

-

A055F1D0R0-50E

-

A055B1DAR0-50E

A055C1D0R0-50E

500

60

-

-

-

-

9F60FJD100

9F62DCB080

A055F1D0R0-80E

-

A055B1DAR0-80E

A055C1D0R0-80E

750

90

-

-

-

-

9F60HJD125

9F62DCB125

A055F1D0R0-125E

-

A055B1DAR0-125E

A055C1D0R0-125E

1000

120

-

-

-

-

9F60HJD150

9F62DCB150

A055F1D0R0-200E

-

A055B1DAR0-200E

A055C1D0R0-200E

1500

181

-

-

-

-

-

9F62FCB250

A055F2D0R0-250E

-

A055B2DAR0-250E

A055C1D0R0-250E

2000

241

-

-

-

-

-

9F62FCB350

A055F2D0R0-300E

-

A055B2DAR0-400E

A055C1D0R0-400E

2500

301

-

-

-

-

-

9F62FCB400

A055F2D0R0-400E

-

A055B2DAR0-400E

A055C1D0R0-400E

3000

361

-

-

-

-

-

-

-

9F62KCB500

A055B2D0R0-500E

A055C2D0R0-500E

3750

421

-

-

-

-

-

-

-

9F62KCB600

A055B2D0R0-600E

A055C2D0R0-600E

4000

482

-

-

-

-

-

-

-

9F62KCB700

A055B2D0R0-600E

A055C2D0R0-600E

4500

542

-

-

-

-

-

-

-

9F62KCB700

A055B3D0R0-750E

-

5000

602

-

-

-

-

-

-

-

9F62KCB800

A055B3D0R0-900E

-

5500

662

-

-

-

-

-

-

-

9F62KCB900

A055B3D0R0-900E

-

6000

723

-

-

-

-

-

-

-

9F62KCB900

A055B3D0R0-900E

-

2

A055F

A055F

“DDDD”

Fuses will carry transformer magnetizing inrush current of 25 times full load amperes for .01 second and 12 times full load current for .1 second
EJO fuses can be used outdoors without an enclosure		2 the self cooled rating of the transformer
3 Phase 6900 Volt Typical Primary Fuse Sizing Chart
2 “ Ferrule mounting

3 “ Ferrule mounting (single and double)

Bolt on

Transformer

Full Load

Rating kVA2

Amperes

9F60 EJO “C”

9F62 EJO “C”

9F60 EJO “D”

9F62 EJO “D”

A825X

A072B

9

0.75

9F60DJE003

-

-

-

-

-

15

1.3

9F60DJE005

-

-

-

-

-

30

2.5

9F60DJE010

-

-

-

-

-

45

3.8

9F60DJE010

-

-

-

-

-

75

6.3

-

9H62HCC020

9F60FJE020

-

A825X10-1

-

112.5

9.4

-

9H62HCC020

9F60FJE025

-

A825X15-1

-

150

13

-

9H62HCC025

9F60FJE040

-

A825X20-1

-

225

19

-

9H62HCC040

9F60FJE050

-

A825X25-1

-

300

25

-

9H62HCC040

9F60FJE065

-

A825X40-1

-

500

42

-

-

9F60FJE100

9F62DCC065

A825X65-1

-

750

63

-

-

9F60HJE125

9F62DCC080

A825X80-1

-

1000

84

-

-

9F60HJE150

9F62DCC150

A825X125-1

-

1500

126

-

-

-

9F62FCC200

A825X200-1

-

2000

168

-

-

-

9F62FCC250

-

A072B2D0R0-250E

2500

209

-

-

-

-

-

A072B2D0R0-300E

3000

251

-

-

-

-

-

A072B2D0R0-350E

3500

293

-

-

-

-

-

A072B2D0R0-400E

Fuses will carry transformer magnetizing inrush current of 25 times full load amperes for .01 second and 12 times full load current for .1 second
EJO fuses can be used outdoors without an enclosure		2 the self cooled rating of the transformer

Maximum Fuse Size
The Code allows primary fuses to be sized at 250% of transformer primary current rating or next standard fuse rating. Sizing
this large may not provide adequate protection. Maximum fuse size should be determined by making sure the fuse total
clearing curve does not exceed transformer damage curve. The transformer manufacturer should be consulted to determine
transformer overload and short circuit withstand capability.

P18

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Primary Fuses For MV 3-Phase Power Transformers
3 Phase 7200 Volt Typical Primary Fuse Sizing Chart
Transformer

Full Load

2 “ Ferrule mounting

Rating kVA2

Amperes

9F60 EJO “C”

9F62 EJO “C”

9F60 EJO “D”

3 “ Ferrule mounting (single and double)
9F62 EJO “D”

A825X

Bolt on
A072B

9

0.72

9F60DJE003

-

-

-

-

-

15

1.2

9F60DJE005

-

-

-

-

-

30

2.4

9F60DJE010

-

-

-

-

-

45

3.6

9F60DJE010

-

-

-

-

-

75

6.0

-

-

9F60FJE020

-

-

-

112.5

9.0

-

9F62HCC020

9F60FJE025

-

-

-

150

12

-

9F62HCC020

9F60FJE040

-

A825X20-1

-

225

18

-

9F62HCC040

9F60FJE050

-

A825X25-1

-

300

24

-

9F62HCC040

9F60FJE065

-

A825X40-1

-

500

40

-

9F62HCC050

9F60FJE100

-

A825X65-1

-

750

60

-

-

9F60HJE125

9F62DCC080

A825X80-1

-

1000

80

-

-

9F60HJE150

9F62DCC125

A825X125-1

-

1500

120

-

-

9F60HJE200

9F62FCC200

A825X200-1

-

2000

161

-

-

-

9F62FCC200

A825X200-1

-

2500

201

-

-

-

9F62FCC250

-

A072B2D0R0-250E

3000

241

-

-

-

-

-

A072B2D0R0-300E

3500

281

-

-

-

-

-

A072B2D0R0-350E

4000

321

-

-

-

-

-

A072B2D0R0-400E

Fuses will carry transformer magnetizing inrush current of 25 times full load amperes for .01 second and 12 times full load current for .1 second
EJO fuses can be used outdoors without an enclosure
2
the self cooled rating of the transformer

3 Phase 12,000 Volt Typical Primary Fuse Sizing Chart
Rating
kVA2

Full Load
Amperes

2 “ Ferrule mounting
9F60 EJ

9F60 EJO

9F62 EJO

“C”

“C”

“C”

3 “ Ferrule mounting (single and double)
A155F

9F60 EJO

9F62 EJO

“D”

“D”

Bolt on
9F62 EJO

A155F

“DDDD”

Clip Lock

A155B

A155C

9

0.43

9F60CJH002

9F60DMH002

-

-

-

-

-

-

-

-

15

0.72

9F60CJH003

9F60DMH003

-

-

-

-

-

-

-

-

30

1.4

9F60CJH005

9F60DMH005

-

-

-

-

-

-

-

-

45

2.2

9F60CJH007

9F60DMH007

-

A155F1C0R0-5E

-

-

-

-

-

-

75

3.6

9F60CJH010

9F60DMH010

-

A155F1C0R0-7E

-

-

-

-

-

-

112.5

5.4

-

-

9F62HDD020

A155F1C0R0-10E

9F60FMH020

-

A155F1D0R0-10E

-

-

A155C1D0R0-10E

150

11

-

-

9F62HDD020

A155F1C0R0-10E

9F60FMH025

-

A155F1D0R0-10E

-

-

A155C1D0R0-10E

225

11

-

-

9F62HDD020

A155F1C0R0-15E

9F60FMH030

-

A155F1D0R0-15E

-

-

A155C1D0R0-15E

300

14

-

-

9F62HDD025

A155F1C0R0-20E

9F60FMH040

-

A155F1D0R0-20E

-

-

A155C1D0R0-20E

500

24

-

-

-

-

9F60HMH065

-

A155F1D0R0-40E

-

-

A155C1D0R0-40E

750

36

-

-

-

-

9F60HMH100

9F62DDD065

A155F1D0R0-50E

-

-

A155C1D0R0-50E

1000

48

-

-

-

-

9F60HMH100

9F62DDD065

A155F1D0R0-65E *

-

-

A155C2D0R0-65E

1500

72

-

-

-

-

-

9F62DDD100

A155F1D0R0-100E *

-

-

A155C2D0R0-100E

2000

96

-

-

-

-

-

9F62FDD150

A155F2D0R0-150E

-

-

A155C3D0R0-150E

2500

120

-

-

-

-

-

9F62FDD175

A155F2D0R0-175E

-

A155B2D0R0-200E

A155C3D0R0-200E

3000

144

-

-

-

-

-

9F62FDD200

A155F2D0R0-200E

-

A155B2D0R0-200E

A155C3D0R0-200E

3500

169

-

-

-

-

-

-

-

-

A155B3D0R0-300E

A155C3D0R0-250E

4000

193

-

-

-

-

-

-

-

-

A155B3D0R0-300E

A155C3D0R0-250E

4500

217

-

-

-

-

-

-

-

9F62KED300

A155B3D0R0-300E

A155C3D0R0-300E

5000

241

-

-

-

-

-

-

-

9F62KED300

A155B3D0R0-300E

A155C3D0R0-300E

Fuses will carry transformer magnetizing inrush current of 25 times full load amperes for .01 second and 12 times full load current for .1 second
EJO fuses can be used outdoors without an enclosure
		2
the self cooled rating of the transformer
		* use F2 in place of F1 for double barrel fuses

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P

Transformer

P19

Primary Fuses For MV 3-Phase Power Transformers
3 Phase 12,470 Volt Typical Primary Fuse Sizing Chart
Transformer

Full Load

Rating kVA

Amperes

2

2 “ Ferrule mounting
9F60 EJ

9F60 EJO

9F62 EJO

“C”

“C”

“C”

3 “ Ferrule mounting (single and double)
A155F

9F60 EJO

9F62 EJO

“D”

“D”

Bolt on
9F62 EJO

A155F

Clip Lock

A155B

“DDDD”

A155C

30

1.4

9F60CJH005

9F60DMH005

-

-

-

-

-

-

-

-

45

2.1

9F60CJH007

9F60DMH007

-

A155F1C0R0-5E

-

-

-

-

-

-

75

3.5

9F60CJH010

9F60DMH010

-

A155F1C0R0-7E

-

-

-

-

-

-

112.5

5.2

-

-

9F62HDD020

A155F1C0R0-10E

9F60FMH020

-

A155F1D0R0-10E

-

-

A155C1D0R0-10E

150

7.0

-

-

9F62HDD020

A155F1C0R0-10E

9F60FMH020

-

A155F1D0R0-10E

-

-

A155C1D0R0-10E

225

10

-

-

9F62HDD020

A155F1C0R0-15E

9F60FMH025

-

A155F1D0R0-15E

-

-

A155C1D0R0-15E

300

14

-

-

9F62HDD025

A155F1C0R0-20E

9F60FMH040

-

A155F1D0R0-20E

-

-

A155C1D0R0-20E

500

23

-

-

9F62HDD030

A155F1C0R0-30E

9F60FMH050

-

A155F1D0R0-30E

-

-

A155C1D0R0-30E

750

35

-

-

-

-

9F60HMH065

9F62DDD065

A155F1D0R0-50E

-

-

A155C1D0R0-50E

1000

46

-

-

-

-

9F60HMH080

9F62DDD065

A155F1D0R0-65E*

-

-

A155C1D0R0-65E

1500

70

-

-

-

-

-

9F62DDD100

A155F1D0R0-100E*

-

-

A155C1D0R0-100E

2000

93

-

-

-

-

-

9F62FDD125

A155F2D0R0-125E

-

-

A155C2D0R0-125E

2500

116

-

-

-

-

-

9F62FDD150

A155F2D0R0-150E

-

A155B2D0R0-200E

A155C3D0R0-200E

3000

139

-

-

-

-

-

9F62FDD175

A155F2D0R0-175E

-

A155B2D0R0-200E

A155C3D0R0-200E

3500

162

-

-

-

-

-

9F62FDD200

A155F2D0R0-200E

-

A155B2D0R0-200E

A155C3D0R0-200E

4000

185

-

-

-

-

-

-

-

-

A155B2D0R0-300E

A155C3D0R0-250E

4500

209

-

-

-

-

-

-

-

-

A155B2D0R0-300E

A155C3D0R0-250E

5000

232

-

-

-

-

-

-

-

9F62KED300

A155B2D0R0-300E

A155C3D0R0-300E

5500

255

-

-

-

-

-

-

-

9F62KED300

A155B2D0R0-300E

A155C3D0R0-300E

Fuses will carry transformer magnetizing inrush current of 25 times full load amperes for .01 second and 12 times full load current for .1 second
EJO fuses can be used outdoors without an enclosure 	
	2
the self cooled rating of the transformer 		
* use F2 in place of F1 for double barrel fuses

3 Phase 13,200 Volt Typical Primary Fuse Sizing Chart
2 “ Ferrule mounting

Transformer Full Load
Rating kVA2 Amperes 9F60 EJ “C”

9F60 EJO

9F62 EJO

“C”

“C”

3 “ Ferrule mounting (single and double)
A155F

9F60 EJO

9F62 EJO

“D”

“D”

A155F

Bolt on
9F62 EJO
“DDDD”

A155B

A155C

9

0.4

9F60CJH002

9F60DMH002

-

-

-

-

-

-

-

-

15

0.7

9F60CJH003

9F60DMH003

-

-

-

-

-

-

-

-

30

1.3

9F60CJH005

9F60DMH005

-

-

-

-

-

-

-

-

45

2.0

9F60CJH007

9F60DMH007

-

A155F1C0R0-5E

-

-

-

-

-

-

75

3.3

9F60CJH010

9F60DMH010

-

A155F1C0R0-7E

-

-

-

-

-

-

112.5

4.9

-

-

-

A155F1C0R0-10E

9F60FMH015

-

A155F1D0R0-10E

-

-

A155C1D0R0-10E

150

6.6

-

-

-

A155F1C0R0-10E

9F60FMH020

-

A155F1D0R0-10E

-

-

A155C1D0R0-10E

225

10

-

-

9F62HDD020

A155F1C0R0-15E

9F60FMH030

-

A155F1D0R0-15E

-

-

A155C1D0R0-15E

300

13

-

-

9F62HDD025

A155F1C0R0-20E

9F60FMH040

-

A155F1D0R0-20E

-

-

A155C1D0R0-20E

500

22

-

-

9F62HDD030

A155F1C0R0-30E

9F60HMH065

-

A155F1D0R0-30E

-

-

A155C1D0R0-30E

750

33

-

-

-

-

9F60HMH080

9F62DDD050

A155F1D0R0-50E

-

-

A155C1D0R0-50E

1000

44

-

-

-

-

9F60HMH100

9F62DDD065

A155F1D0R0-65E*

-

-

A155C1D0R0-65E

1500

66

-

-

-

-

-

9F62DDD100

A155F1D0R0-100E*

-

-

A155C1D0R0-100E

2000

88

-

-

-

-

-

9F62FDD125

A155F2D0R0-125E

-

-

A155C2D0R0-125E

2500

109

-

-

-

-

-

9F62FDD150

A155F2D0R0-150E

-

-

A155C3D0R0-150E

3000

131

-

-

-

-

-

9F62FDD175

A155F2D0R0-200E

-

A155B2D0R0-200E

A155C3D0R0-200E

-

3500

153

-

-

-

-

-

9F62FDD200

A155F2D0R0-200E

4000

175

-

-

-

-

-

-

-

4500

197

-

-

-

-

-

-

-

5000

219

-

-

-

-

-

-

-

5500

241

A155B2D0R0-200E

A155C3D0R0-200E

A155B2D0R0-200E

A155C3D0R0-250E

A155B2D0R0-300E

A155C3D0R0-250E

9F62KED300

A155B2D0R0-300E

A155C3D0R0-300E

9C62KED300

A155B2D0R0-300E

A155C3D0R0-300E

Fuses will carry transformer magnetizing inrush current of 25 times full load amperes for .01 second and 12 times full load current for .1 second
EJO fuses can be used outdoors without an enclosure
2
the self cooled rating of the transformer
* use F2 in place of F1 for double barrel fuses

P20

Clip Lock

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Primary Fuses For MV 3-Phase Power Transformers
3 Phase 13,800 Volt Typical Primary Fuse Sizing Chart
2 “ Ferrule mounting

Transformer Full Load

Rating kVA2 Amperes 9F60 EJ “C” 9F60 EJO “C”

3 “ Ferrule mounting (single and double)

9F62 EJO

A155F

“C”

9F60 EJO

9F62 EJO

“D”

“D”

Bolt on
9F62 EJO

A155F

“DDDD”

Clip Lock

A155B

A155C

30

1

9F60CJH005

9F60DMH005

-

-

-

-

-

-

-

-

45

2

9F60CJH007

9F60DMH007

-

A155F1C0R0-5E

-

-

-

-

-

-

75

3

9F60CJH010

9F60DMH010

-

A155F1C0R0-7E

-

-

-

-

-

-

112.5

5

-

-

-

A155F1C0R0-10E

9F60FMH015

-

A155F1D0R0-10E

-

-

A155C1D0R0-10E

150

6

-

-

-

A155F1C0R0-10E

9F60FMH020

-

A155F1D0R0-10E

-

-

A155C1D0R0-10E

225

9

-

-

9F62HDD020

A155F1C0R0-15E

9F60FMH030

-

A155F1D0R0-15E

-

-

A155C1D0R0-15E

300

13

-

-

9F62HDD025

A155F1C0R0-20E

9F60FMH030

-

A155F1D0R0-20E

-

-

A155C1D0R0-20E

500

21

-

-

9F62HDD030

A155F1C0R0-30E

9F60FMH040

-

A155F1D0R0-30E

-

-

A155C1D0R0-30E

750

31

-

-

-

-

9F60HMH065

9F62DDD050

A155F1D0R0-50E

-

-

A155C1D0R0-50E

1000

42

-

-

-

-

9F60HMH080

9F62DDD065

A155F1D0R0-65E*

-

-

A155C1D0R0-65E

1500

63

-

-

-

-

9F60HMH100

9F62DDD100

A155F1D0R0-100E*

-

-

A155C1D0R0-100E

2000

84

-

-

-

-

-

9F62FDD125

A155F2D0R0-125E

-

-

A155C2D0R0-125E

2500

105

-

-

-

-

-

9F62FDD150

A155F2D0R0-150E

-

-

A155C3D0R0-150E

3000

126

-

-

-

-

-

9F62FDD200

A155F2D0R0-200E

-

A155B2D0R0-200E

A155C3D0R0-200E

3500

147

-

-

-

-

-

9F62FDD200

A155F2D0R0-200E

-

A155B2D0R0-200E

A155C3D0R0-200E

4000

168

-

-

-

-

-

-

-

-

A155B2D0R0-300E

A155C3D0R0-250E

4500

188

-

-

-

-

-

-

-

-

A155B2D0R0-300E

A155C3D0R0-250E

5000

209

-

-

-

-

-

-

-

-

A155B2D0R0-300E

A155C3D0R0-300E

5500

230

-

-

-

-

-

-

-

9F62KED300

A155B2D0R0-300E

A155C3D0R0-300E

6000

251

-

-

-

-

-

-

-

9F62KED300

A155B2D0R0-300E

A155C3D0R0-300E

Fuses will carry transformer magnetizing inrush current of 25 times full load amperes for .01 second and 12 times full load current for .1 second
EJO fuses can be used outdoors without an enclosure
2
the self cooled rating of the transformer
* use F2 in place of F1 for double barrel fuses
3 Phase 14,400 Volt Typical Primary Fuse Sizing Chart
Transformer Full Load

9F60 EJO

3 “ Ferrule mounting (single and double)
9F60 EJO

9F62 EJO

“D”

“D”

Bolt on
9F62 EJO

Clip Lock

A155B

A155C

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

A155F1C0R0-10E

9F60FMH015

-

A155F1D0R0-10E

-

-

A155C1D0R0-10E

-

A155F1C0R0-10E

9F60FMH020

-

A155F1D0R0-10E

-

-

A155C1D0R0-10E

-

9F62HDD020

A155F1C0R0-15E

9F60FMH030

-

A155F1D0R0-15E

-

-

A155C1D0R0-15E

-

-

9F62HDD020

A155F1C0R0-20E

9F60FMH040

-

A155F1D0R0-20E

-

-

A155C1D0R0-20E

20

-

-

9F62HDD030

A155F1C0R0-30E

9F60FMH050

-

A155F1D0R0-30E

-

-

A155C1D0R0-30E

750

30

-

-

-

-

9F60FMH080

9F62DDD050

A155F1D0R0-40E

-

-

A155C1D0R0-50E

1000

40

-

-

-

-

9F60FMH100

9F62DDD065

A155F1D0R0-65E*

-

-

A155C1D0R0-65E

9F62 EJO “C” A155F

A155F

Rating kVA

Amperes 9F60 EJ “C”

9

0.4

9F60DMH002

9F60CJH002

-

-

-

-

-

15

0.6

9F60DMH003

9F60CJH003

-

-

-

-

-

30

1.2

9F60DMH005

9F60CJH005

-

-

-

-

45

1.8

9F60DMH007

9F60CJH007

-

A155F1C0R0-5E

-

75

3.0

9F60DMH010

9F60CJH010

-

A155F1C0R0-7E

112.5

5

-

-

-

150

6

-

-

225

9

-

300

12

500

2

“C”

“DDDD”

1500

60

-

-

-

-

-

9F62DDD080

A155F1D0R0-80E*

-

-

A155C1D0R0-100E

2000

80

-

-

-

-

-

9F62FDD125

A155F2D0R0-125E

-

-

A155C2D0R0-125E

2500

100

-

-

-

-

-

9F62FDD150

A155F2D0R0-150E

-

-

A155C3D0R0-150E

3000

120

-

-

-

-

-

9F62FDD175

A155F2D0R0-175E

-

A155B2D0R0-200E

A155C3D0R0-200E

3500

140

-

-

-

-

-

9F62FDD200

A155F2D0R0-200E

-

A155B2D0R0-200E

A155C3D0R0-200E

4000

161

-

-

-

-

-

-

-

-

A155B2D0R0-200E

A155C3D0R0-250E

4500

181

-

-

-

-

-

-

-

-

A155B2D0R0-300E

A155C3D0R0-250E

5000

201

-

-

-

-

-

-

-

-

A155B2D0R0-300E

A155C3D0R0-300E

5500

221

-

-

-

-

-

-

-

9F62KED300

A155B2D0R0-300E

A155C3D0R0-300E

6000

241

-

-

-

-

-

-

-

9F62KED300

A155B2D0R0-300E

A155C3D0R0-300E

P

2 “ Ferrule mounting

Fuses will carry transformer magnetizing inrush current of 25 times full load amperes for .01 second and 12 times full load current for .1 second
EJO fuses can be used outdoors without an enclosure
2
the self cooled rating of the transformer
* use F2 in place of F1 for double barrel fuses

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P21

Primary Fuses For MV 3-Phase Power Transformers
3 Phase 22,000 Volt Typical Primary Fuse Sizing Chart
Transformer Rating kVA2

Full Load Amperes

30

0.79

2 “ Ferrule mounting

3 “ Ferrule mounting (single and double)

9F60 EJO “C”

9F60 EJO “D”

9F60DNJ003

-

45

1.18

9F60DNJ004

-

75

1.97

9F60DNJ005

-

112.5

2.95

9F60DNJ006

-

150

3.93

9F60DNJ010

-

225

5.9

-

9F60FNJ020

300

7.84

-

9F60FNJ020

500

13.1

-

9F60FNJ030

750

19.7

-

9F60FNJ050

1000

26.2

-

9F60HNJ065

1500

39.4

-

9F60HNJ080

2000

52.4

-

9F60HNJ100

Fuses will carry transformer magnetizing inrush current of 25 times full load amperes for .01 second and 12 times full load current for .1 second
EJO fuses can be used outdoors without an enclosure
2
the self cooled rating of the transformer

3 Phase 33.,000 Volt Typical Primary Fuse Sizing Chart
Transformer Rating kVA2

Full Load Amperes

45
75

3 “ Ferrule mounting (single and double)
9F60 EJO “D” with indicator

9F60 EJO “D” without indicator

0.79

9F60FPK002

9F60FPT002

1.31

9F60FPK005

9F60FPT005

112.5

1.98

9F60FPK005

9F60FPT005

150

2.62

9F60FPK007

9F60FPT007

225

3.96

9F60FPK010

9F60FPT010

300

5.26

9F60FPK015

9F60FPT015

500

8.71

9F60FPK025

9F60FPT025

750

13.1

9F60FPK030

9F60FPT030

1000

17.5

9F60FPK040

9F60FPT040

1500

26.2

9F60HPK065

9F60HPT065

2000

35

9F60HPK065

9F60HPT065

2500

43.7

9F60HPK080

9F60HPT080

Fuses will carry transformer magnetizing inrush current of 25 times full load amperes for .01 second and 12 times full load current for .1 second
EJO fuses can be used outdoors without an enclosure
2
the self cooled rating of the transformer

P22

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Primary Fuses For LV Control Transformers
For example: 300VA Transformer, 600 V primary.

Control circuit transformers used as part of a motor control
circuit are to be protected as outlined in Tables 1 & 2 (p. P14)
with one important exception. Primary fuses may be sized
up to 500% of transformer rated primary current if the rated
primary current is less than 2 amperes.

Ipri = Transformer VA = 300 = 1/2A = FLA
Primary V
600
The fuse time-current curve must lie to the right of the point
40 x (1/2A) = 20A @ .01 sec.

When a control circuit transformer is energized, the typical
magnetizing inrush will be 25-40 times rated primary full load
current (FLA) for the first 1/2 cycle and dissipates to rated
current in a few cycles. Fuses must be sized so they do
not open during this inrush. We recommend that fuses be
selected to withstand 40 x FLA for .01 sec. and to stay within
the NEC guidelines specified above.

Secondary fuses are still sized at 125% of the
secondary FLA.

Recommended Primary Fuses for Single Phase Control Transformers
600 Volt Primary

480 Volt Primary

VA

FLA

ATQR

ATMR

A6D-R+

AJT+

TRS-R

FLA

ATQR

ATMR

A6D-R+

AJT+

TRS-R

25

.042

1/10

2/10

2/10

-

1/10

.052

1/10

1/4

1/4

-

1/10

50

.083

1/4

3/10*

4/10

-

2/10

.104

1/4

1/2*

1/2

-

2/10

75

.125

1/4

1/2*

6/10

-

2/10

.156

3/10

3/4*

6/10

-

2/10

100

.167

3/10

3/4*

8/10

-

3/10

.208

4/10

1

1

1

3/10

130

.22

4/10

1

1

1

4/10

.27

1/2

1

1

1-1/2

4/10

150

.25

1/2

1*

1-1/4

1

4/10

.313

1/2

1-1/2

1-4/10

1-1/2

4/10

200

.33

1/2

1-1/2

1-6/10

1-1/2

6/10

.417

6/10

2

2

2

6/10

250

.42

6/10

2

2

2

6/10

.52

8/10

2

2-1/2

2-1/2

6/10

300

.50

1

2

2-1/2

2

8/10

.62

1-1/2

3

3

3

8/10

350

.583

1-1/4

2

2-8/10

2

1

.73

1-1/2

3-1/2

3-1/2

3-1/2

1

500

.833

1-1/2

4

4

4

1-1/4

1.04

2

5

4

4

1-4/10

750

1.25

2-1/2

6

4

4

1-6/10

l.56

3*

7

5

5

2

1000

1.67

3

8

5

5

2-1/4

2.08

4+

-

5+

5+

3

1500

2.5

5+

-

6+

6+

4

3.125

7+

-

6-1/4+

6-1/4+

4

2000

3.33

8+

-

8+

8+

5

4.17

10+

-

7+

7+

5

3000

5.00

12+

-

12+

12+*

8

6.25

15+*

-

15+*

15+

8

5000

8.33

20+*

-

20+*

20+**

12+

10.4

-

-

25+*

25+*

15+

30+*

30+**

-

35+**

35+**

20+

50+**
120 Volt Primary

50+**

30+

7500

12.5

30+*

-

10000

16.7

-

-

40+*
40+**
240 Volt Primary

17-1/2+

15.6

-

25+

20.8

-

25

.104

2/10

1/2

1/2

-

2/10

.21

4/10

1

1

1

3/10

50

.21

4/10

1

1

1

3/10

.42

6/10

2

2

2

6/10

75

.31

1/2

1-1/2

1-4/10

1-1/2

4/10

.6

1

3

3

3

8/10

100

.42

6/10

2

2

2

6/10

.83

1-1/2

4

4

4

1

130

.54

1

2-1/2

2-1/2

2-1/2

8/10

1.08

2-1/2

5

4

4

1-6/10

150

.625

1

3

3

3

8/10

1.25

2-1/2

6

4

4

1-6/10

200

.83

1-1/2

4

3-1/2

3-1/2

1

1.67

3*

8

5

5

2-1/4

250

1.04

2

5

4

4

1-4/10

2.08

4+

-

5+

5+

2-8/10

300

1.25

2-1/2

6

4

4

1-6/10

2.5

5+

-

6+

6+

3-2/10

350

1.46

3*

7

5

5

2

2.92

7+

-

6+

6+

4

500

2.08

4+

-

5+

5+

2-8/10

4.17

10+

-

10+

6

5-6/10

750

3.13

7+

-

6-1/4+

6-1/4+

4

6.25

15+*

-

15+**

15+

8

-

1000

4.2

10+

1500

6.25

15+

7

7

5-6/10

8.33

20+*

-

20+**

20+*

12+

15+

15+

8

12.5

30+*

-

30+

30+

15

2000

8.3

20+*

-

20+**

20+**

12

16.7

-

-

40+**

40+

25+

3000

12.5

30+*

-

30+**

30+**

15

25

-

-

60+**

60+*

35+

5000

20.8

-

-

50+**

50+*

25

41.7

-

-

100+**

100+**

60+

7500

31.3

-

-

70+**

70+**

40+

62.5

-

-

150+**

150+**

90+

10000

41.7

-

-

100+**

100+**

60+

83.3

-

-

200+**

200+**

125+

P

Trans

The above fuses will withstand 40 x FLA for .01 second except where noted.
+ Secondary fusing required.
* Fuse will withstand 30 x FLA for .01 second. 	
** Fuse will withstand 35 x FLA for .01 second.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P23

Surge-Trap® SPD Application Information
What is the Surge-Trap SPD?
The Surge-Trap is a branded surge protection device (SPD) that utilizes Mersen’s patented thermally protected metal oxide
varistor (TPMOV®) technology. This technology eliminates the need for fuses to be installed in series with the Surge-Trap
SPD, which saves money and panel space. Surge-Trap SPD is typically installed in industrial control panels to protect
sensitive electrical equipment from harmful voltage transients. Nearly 80% of all transients are caused by equipment or power
disturbances within a facility.

What Types of Ratings Do SPDs Have?
Do SPDs have a current rating? This is a trick question! They do not have a continuous current rating however they do have
other important current-based ratings. They are required to have a short circuit current rating (SCCR), which is the maximum
rms current at a specified voltage the SPD can withstand.
The nominal discharge current (In) is new to UL 1449 Third Edition (effective 9/29/09). This is the peak value of the current
(20kA maximum) through the SPD (8/20µs waveform) where the SPD remains functional after 15 surges.
There are two main voltage ratings for an SPD, the first is maximum continuous operating voltage (MCOV) which is the
maximum rms voltage that may be applied to the SPD per each connected mode.
Voltage protection rating (VPR) is determined as the nearest high value (from a list of preferred values) to the measured
limiting voltage determined during the transient-voltage surge suppression test using the combination wave generator at a
setting of 6kV, 3kA.

How Do I Select The Correct SPD?
When selecting an SPD you must make sure that the available fault current is less than or equal to the SCCR of the SPD. The
nominal discharge current should be as high as possible because an SPD with a higher In will be able to handle more surges
(at lower currents) then one with a lower In.
Mersen makes it easy to select the correct Surge-Trap SPD. All you need to know is the system voltage, configuration and
short circuit current. All Surge-Trap SPDs have a 100kA SCCR (without fuses), which you need to make sure is not exceeded.
From the selection chart, find your voltage configuration and preferred protections modes. There is no need to worry about the
nominal discharge current as all Surge-Trap SPDs are rated at the UL maximum 20kA.

P24

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Surge-Trap® SPD Application Information
How Is an SPD Installed and How Does It Work?
A Surge-Trap SPD is always installed in parallel with the load. When the circuit has the normal operating voltage the SurgeTrap SPD will not be conducting current. Once the system experiences an overvoltage the Surge-Trap SPD will “turn on” and
begin to conduct the extra voltage to ground, allowing the load to continue running at the correct voltage. This operation is
similar to a pressure relief valve in a steam system.
L+

L2

G

L-

G

G/N

G/N

G

G/N

L1

L

N

N
G

Single Phase
2 Wire + Ground

L2
N

L2
L3
G

L2
G

Split Phase
3 Wire + Ground

L1

L1

3 Phase Delta
3 Wire + Ground

L3
G

3 Phase Wye
4 Wire + Ground

How Do I Retro Fit an Existing Panel?
Providing there is adequate space, retro fitting an existing panel with a Surge-Trap SPD is easy. Typical industrial control
panels will have a main disconnect that feeds a power distribution block (PDB) and then on to the individual loads. The SurgeTrap SPD mounts on standard 35mm DIN-rail typically found inside the panel. It should be installed as close as possible to the
PDB and connected with #6-#14 AWG, the wire should not exceed 20” in length. It is important to make sure the wires are not

P

twisted together nor have any loops, as this will result in higher let-thru voltages.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P25

Surge-Trap® SPD Application Information
Q1: What is SPD?
A: SPD is an abbreviation for “Surge Protective Device.” A SPD is a device that attenuates (reduces in magnitude) random,
high energy, short duration electrical power anomalies caused by utilities, atmospheric phenomena, or inductive loads. Such
anomalies occur in the form of voltage and current spikes with duration of less than half an AC cycle. These high-energy power
spikes can damage sensitive electronic equipment, such as computers, instrumentation, and process controllers.
Q2: How do surge suppressors work?
A: Surge Suppressors are designed to divert high-energy power away from a load by providing a lower impedance path to
common point earth ground. Surge suppressors used most often for panel board protection have metal oxide varistors (MOVs)
connected in parallel.
Q3: What types of components make up a surge suppressor?
A: The device most commonly used in an AC surge suppressor is an MOV comprised of solid-state zinc oxide with multiple
junctions. MOVs provide low impedance when conducting, and are packaged for specific voltages and current handling
capacities. Other devices (more typically found in DC applications) include single junction diodes and gas tubes that ionize at
preset voltages.
Q4: Where are surge suppressors installed?
A: AC surge suppressors are typically installed in these three areas:
•	 At a utility service entrance for protection of an entire facility.
•	 In distribution panel boards and switchboards for protection of sensitive downstream loads;
•	 Connected to a wall outlet for individual protection of a specific piece of equipment, such as a computer or solid-state
controller.
Q5: What is surge current capacity?
A: Surge current capacity, as defined by NEMA standards, is the maximum level of current a surge suppressor can withstand
for a single transient event. This level is used to indicate the protection capacity of a surge suppressor.
Q6: What is clamping voltage?
A: Clamping voltage, also known as suppressed voltage rating (SVR), is the voltage a surge suppressor permits to pass to
the attached load during a transient event. Clamping voltage is a performance measurement of a surge suppressor’s ability
to attenuate a transient. This performance value is confirmed by Underwriters Laboratories (UL) during tests conducted while
evaluating a surge suppressor for listing.
Q7: What features should be considered when selecting a surge suppressor?
A: Two important areas to consider during the selection of a surge suppressor are performance and safety, and include the
following criteria:
Performance: 1) surge current capacity; and 2) Short circuit rating.
Make sure your surge device is not fuse limited. Many manufactures need fusing in front of the device to pass UL testing
conditions.

P26

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Surge-Trap® SPD Application Information
Q8: What is important when specifying a SPD?
A: When specifying SPD, submit a clear, concise specification detailing the required performance and design features. A
minimum specification should include:
• UL surge rating
• Suppression rating
• Short circuit rating
• Peak surge current per mode (L-N, L-G, and N-G)
• Voltage and configuration of electrical service
Q9: What is the difference between UL 1449 Listed and UL 1449 Component Recognized?
A: UL 1449 Component Recognized products are required to pass the same performance tests as UL 1449 Listed products.
The main difference is the listed devices are packaged differently, meaning they are tested and listed in stand-alone
enclosures.
Q: What key changes were made in the UL 1449 3rd Edition?
A: The UL 1449 3rd Edition includes all of the 2nd Edition changes plus the addition of more rigorous safety testing
requirements. The major differences include (1) change in terminology from Transient Voltage Surge Suppressors to Surge
Protective Devices, (2) the UL 3rd Edition is now an American National Standard (ANSI), (3) addition of nominal discharge
current ratings and markings (4) duty cycle test at nominal discharge current, and (5) measured limiting voltage now
performed at 6kV / 3kA.
Q10: What are C62.41 and C62.45?
A: C62.41 and C62.45 are IEEE standards used to describe the characteristics of a transient and how a surge suppressor is
tested to evaluate performance.
C62.41 defines a transient and describes the transient environment at three separate facility locations. These locations are
a service entrance (Category C-the most severe), a distribution panel board or switchboard (Category B), and a wall outlet
(Category A). C62.41 is also a reference document that specifying engineers refer to for application information for defining a
transient environment in a particular facility location. C62.45 describes in detail how a surge suppressor performance test is to
be conducted.
Q11. How is the Surge-Trap SPD more cost efficient than other SPD options?
A: The Surge-Trap SPD is a no-fuse surge suppressor.
1.	 It does not need coordinated fusing or have the expense of the fuses, fuse holder, additional wiring and in meeting the
UL or IEC requirements/standards.
2.	 Surge-Trap’s compact design helps save valuable space in the cabinet.
3.	 Offers modular and pluggable din-rail style with IP20 grade finger-safe protection.

P

4.	 Complies with latest UL 1449 Third Edition and IEC 61643-1 Standards.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P27

Surge-Trap® SPD Glossary & Definitions
The following definitions apply specifically to surge protective devices (SPD). They are provided for further clarification of the
performance specifications in the data sheets.
Crest Value (peak): The maximum value that a wave, surge, or impulse attains. It is generally associated with the front of a
wave.
Clamping Voltage: The peak voltage across the surge protective device (SPD) measured under the conditions of a specified
surge current and waveform. Peak voltage and peak current are not necessarily coincident in time.
Impulse: A wave (surge) of unidirectional polarity. In testing, the rise time and duration of the impulse are specified, e.g., an
8/20µs impulse, a 10/350µs impulse.
Maximum Continuous Operating Voltage (MCOV): The maximum rms value of the power frequency voltage that may be
applied continuously between the terminals of the surge protective device.
Nominal System Voltage: A nominal value assigned to designate a system of a given voltage class, e.g., 120/240 Volt single
phase. Note: see ANSI C84.1-1989
Operating Duty Cycle: One or more operations per unit of time as specified.
Pulse Life: The number of surges of a specified voltage and current amplitude and waveform that may be applied to a
SPD without causing a change of more than 10 percent in the clamping voltage. The time interval between surges must be
specified.
Maximum Single Impulse Current: The maximum amplitude of current which may be applied for a single 8/20µs impulse
without causing device failure.
Power Dissipation: The power dissipated by a protective device while connected to an AC line of the rated voltage and
frequency while no over voltage condition or surge exists. Steady state power dissipation.
Response Time: The time domain response of a surge protective device to the front of a voltage waveform depends on
the rate-of-rise of the incident wave, the impedance of the surge source and connecting wiring, the effects of protective
device reactance, and the response behavior of conducting mechanisms within active suppression elements. In other words,
response to the front of a wave can be affected more by the test circuit conditions, including lead inductance, than by the
response time of the active suppression element.
Surge: A transient wave of current, potential, or power in an electric circuit.
Surge Let-Through: The voltage seen by the protected load, includes the SPD clamp voltage plus the voltage drop in the
connecting wires. The part of the surge impulse that passes through the protective device.
Surge Protective Device (SPD): A device for limiting the surge voltage on equipment by discharging or diverting surge
current. A SPD should be able to repeatedly perform these functions as specified.
Turn-On Time: The time required for a device to make the transition from an “OFF” state to an “ON” state.
Turn-Off Time: The time required for a device to make the transition from an “ON” state to an “OFF” state.
Voltage-Current (V-I) Characteristics: The relationship between the suppressed voltage and the magnitude of the surge
current which induces this voltage.

P28

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Semiconductor Protection
Solid state devices have progressed through several
generations of sophistication since their introduction in the
1940s. Fuse designs have changed to match solid state
protection demands.

Solid state devices have relatively short thermal time
constants. An overcurrent which may not harm an
electromechanical device can cause catastrophic failure of a
solid state device.

The protection task looks simple- choose a fuse of correct
voltage and ampere rating which will protect a solid state
device (diode, silicon-controlled rectifier, triac, etc.) through
a wide range of overcurrents, yet carry normal rated loads
without deterioration through a long life.

Many solid state devices have an overcurrent withstand
rating which is termed “I2t for fusing”. These values are found
in most power semiconductor application handbooks.

Solid state power devices operate at high current densities.
Cooling is a prime consideration. The fuse should be
cooled with the solid state device. Cycling conditions must
be considered. The ability of solid state devices to switch
high currents at high speed subjects fuses to thermal and
mechanical stresses. Proper fuse selection is mandatory for
long-term reliability.

Fuses intended for solid state device protection are rated in
terms of total clearing I2t. Fuses and devices are matched so
that the total clearing I2t of the fuse is less than the withstand
I2t for the device.
The published fuse total clearing I2t values are derived from
short-circuit test oscillograms of the fuse under controlled
conditions. The end application can vary significantly
from the tested conditions. The specifier must take these
differences into account since they will affect fuse clearing I2t.

For application guidelines, request the Mersen publication titled Power Semiconductor Fuse Application Guide, and
the software program titled Select a Fuse for Power Electronics.

AC applications are more common than DC. This is
why fuses are generally designed, tested and rated for
AC. Fuses rated for AC are also capable of DC circuit
interruption. The key question is how much DC voltage
interrupting capability does an AC rated fuse have? There is
no safe rule of thumb that will convert AC voltage rating to a
DC voltage rating. Testing is required to determine the DC
voltage rating of a fuse. This section covers AC fuses that
have been tested for DC applications. Mersen is a leader in
DC protection, offering a line of DC fuses. Contact Technical
Services for further information.

DC Circuit Parameters

The degree of difficulty of interrupting a DC circuit is a
function of the voltage, current and circuit time constant. The
higher the voltage and time constant, the more difficult the
interruption is for the fuse.
Time constant is defined as t = L/R where:
	
t is time constant in seconds
	
L is inductance in henrys
	
R is resistance in ohms
If rated voltage is applied, 63% of rated current will be
reached in one time constant.

DC Short Circuit

Graph A shows the relationship of current as a function of
time during a DC short circuit.

Graph A- Current as a Function of Time
During a DC Short Circuit

Time Constants (n)
Instantaneous Current (I inst) = Isc [I - e-n]
RMS Current (I rms) = Isc 1 + 2e-n - e-2n - 1.5
			
n
2n
n
Where Isc = short circuit current, n = number of time constants

Example

Given:	 Voltage = 600VDC
	
Circuit Resistance (R) = 0.1 ohm
	
Circuit Inductance (L) = 1.0 x 10-3 henry
Isc = 600 Volts = 6000 Amperes
0.1 ohm

P

DC Circuit Protection

t (time constant) = L/R = 1.0 x 10-3 henry = .01 second
			
0.1 ohm
In the example, if a short circuit occurs, the instantaneous
current will rise to .63 x 6000 = 3780 amperes in .01 second
(one time constant). In .05 second (5 time constants) the shortcircuit current will reach its ultimate value of 6000 amperes.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P29

DC Circuit Protection
Typical Time Constants

The time constant of a circuit is a function of the resistance
and inductance of the components in the circuit. Here are
typical time constants associated with the different DC
voltage sources:
Less than 10 milliseconds	
Less than 25 milliseconds	
10 to 40 milliseconds	
1 second*	

Battery supply of capacitor bank
Bridge circuit
Armature circuit of DC motor
Field winding of DC motor

* Where time constants exceed 100 milliseconds, we do not
recommend the use of fuses. A fuse can be used to interrupt
short circuits in these cases, but only under conditions where
the inductance (load) is effectively by-passed.
Maximum parallel conductor inductance can be assumed to be less
than .5 x 10­–6 henry per foot of conductor. Graph B approximates
conductor inductance based on conductor size and spacing.

Conductor End Views

Graph B- Conductor Inductance

Table 1 shows the voltage ratings and time constants
associated with these standards.
Mersen fuses which have been tested and rated for DC by
third party certification agencies are shown in Table 2 and
Table 3. The Mersen Applications Engineering Department
should be contacted for assistance with applications not
served by these products.

Table 1- DC Parameters of UL and MSHA Standards
Standard

Voltage

Time Constant

Test Current

UL248

Up to 600V DC

.01 second

10kA or higher

300 or 600V DC
MSHA & UL198M

.016 second

10kA or higher

.008 second

1kA to 9.99kA

.006 second

100A to 999A

.002 second

Less than 100A

Table 2- DC Rating of General Purpose Mersen Fuses
Fuse Ampere

DC Voltage

DC Interrupting

Listing Or

Rating

Rating

Rating

Approval

A2D-R

15-600

250

100kA

UL248-1

A3T

1-1200

160

50kA

UL248-1

A4BQ

601-2000

500

100kA

UL248-1

A6D-R

0-600

600

100kA

UL248-1

A6T

1-800

300

100kA

UL248-1

AJT

0-600

500

100kA

UL248-1

ATDR

1/4-30

300

100kA

UL248-1

ATM

1/10-30

600

100kA

UL248-1

ATMR

1/10-30

600

100kA

UL248-1

HSJ

15-600

500

100kA

UL248-1

TRS-R

0-12

600

20kA

UL248-1

TRS-R

15-60

300

20kA

UL248-1

TRS-R

70-600

600

100kA

UL248-1

TRS-RDC

35-400

600

20kA

MSHA

Fuse Family

Table 3-DC Voltage Ratings of Component
Recognized Mersen Fuses*

Third Party Approval Listing

Underwriters Laboratories and the Mine Safety and Health
Administration (MSHA) are third party organizations which
test and list or approve fuses for DC application, respectively.
Two UL standards exist for the DC rating of fuses. UL 248,
entitled Low Voltage Fuses which provides for both AC and
DC rating of UL class fuses in accordance with the Code. The
previous standard UL 198L has been absorbed into UL 248.
UL 198M, entitled Mine-Duty Fuses addresses the DC rating
of Class R and Class K fuses intended for the short circuit
protection of trailing cables in mines. UL198M is equivalent
to the requirements of MSHA, which are administered by the
United States Department of Labor. The MSHA requirements
for approval of DC rated fuses are specified in the Code of
Federal Regulations, Title 30, Part 28.

P30

Fuse Family

Fuse Ampere Rating

DC Voltage

DC Interrupting

A15QS

20-4000

150

50kA

A2Y

1-600

500

100kA

A30QS

35-4500

300

100kA

A50P

10-800

450

79kA

A50QS

0-1200

500

100kA

A5Y TYPE 11

3-50

500

100kA

A60Q

5-40

600

100kA

A6Y

1-600

500

100kA

A70P TYPE 4

10-700

650

100kA

A70P TYPE 4

1200-2000

550

100kA

A70Q

35-600

650

100kA

A7OQS

35-800

700

100kA

ACK

1-400

125

10kA

ACL

30-120

125

10kA

ALS

100-500

125

10kA

CNL

35-750

80

2.5kA

CNN

10-800

80

2.5kA

DCT

5-30

1000

50kA

FSM

0.41-15

1000

20kA

PCF

1-30

500

100kA

PCS

5-40

600

100kA

TGL

70-800

170

100kA

TGN

1-600

170

100kA

TGS

1-70

170

100kA

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

*UL Recognized
Components
complying with
UL248 DC
requirements.

Temperature De-Rating
Ampere ratings for fuses are based on specific test conditions. External factors which influence the ampere rating of a fuse
are terminal connections, air flow across the fuse, and ambient temperature.
The following formulas should be used when de-rating a fuse’s ampere rating for use at an increased ambient temperature of
up to 80°C.
80°C Maximum ambient temperature for installations.

Temperature De-Rating for Low Voltage Fuses
A4J; A2D; A6D; A2K; A6K; TR; TRS

125 - TA
I							
= Irated
new
√ 100

Inew = New Ampere Rating

							

Irated = Nameplate Current Rating

							

TA = Ambient Temperature in °C

FORM 101; A2Y; A6Y; A3T; A6T; DCT; ATM; ATMR; ATDR; ATQR; AJT; HSJ; A4BQ; A4BY; A4BT

150 - TA
I							
= Irated
new
√ 125
							

Irated = Nameplate Current Rating

							

TA = Ambient Temperature in °C

Inew = New Ampere Rating

OT; OTS; TRM

110 - TA
I							
= Irated
new
√
8
							

Irated = Nameplate Current Rating

							

TA = Ambient Temperature in °C

P

Inew = New Ampere Rating

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P31

Temperature De-Rating
80°C Maximum ambient temperature for installations.

Temperature De-Rating for UltraSafe™ Fuse Holders
USM; USCC; US3J; US6J; US14; US22
Multiple Poles					

Temperature De-Rating

Number of Poles

Coefficient

Temperature

Coefficient

1-2-3

1

20°C

1

4-5-6

0.8

30°C

0.95

7-8-9

0.7

40°C

0.9

>10

0.6

50°C

0.8

Temperature De-Rating for Medium Voltage Fuses
A055F1C0R0-5E thru 65E; A055C1C0R0-450E,500E,600E; A055F2D0R0-400E,450E; A055B3D0R0-750E,900E;
A155C1D0R0-80E,100E; A155C2D0R0-125E; A155C3D0R0-150E,300E; A155F1C0R0-5E thru 30E; A155F1D0R0-100E;
A155F2D0R0-150E,175E,200E; A480R12R thru 36R; A072B1DAR0-2R thru 12R; A072B2DAR0-18R,24R; A072F1D0R0-2R
thru 12R; A072F2DAR0-18R,24R; 9F60; 9F62

140 - TA
							
Inew = Irated

√

Inew = New Ampere Rating

100
							

Irated = Nameplate Current Rating

							

TA = Ambient Temperature in °C

A240R2R thru 36R; A480R2R thru 9R; A055C1D0R0-10E thru 400E;
A055C3D0R0-500E,600E; A055F1D0R0-10E thru 200E;
A055F2D0R0-250E,300E,350E; A155C1D0R0-10E thru 65E;
A155F1D0R0-10E thru 80E; A155F2D0R0-65E,80E,100E,125E
							

115 - TA
							
I =I

√ 75
							
new

P32

rated

Inew = New Ampere Rating
Irated = Nameplate Current Rating
TA = Ambient Temperature in °C

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Let-Thru Current and l2t
Current limitation is one of the important benefits provided by
modern fuses. Current-limiting fuses are capable of isolating
a faulted circuit before the fault current has sufficient time
to reach its maximum value. This current-limiting action
provides several benefits:
	
- It limits thermal and mechanical stresses created
by the fault currents.
	
- It reduces the magnitude and duration of the
system voltage drop caused by fault currents.
	
- Current-limiting fuses can be precisely and easily
coordinated under even short circuit conditions to
minimize unnecessary service interruption.
Peak let-thru current (lp) and I2t are two measures of the
degree of current limitation provided by a fuse. Maximum
allowable lp and I2t values are specified in UL standards for
all UL listed current-limiting fuses, and are available on all
semiconductor fuses.

Let-Thru Current

Current

Let-thru current is that current passed by a fuse while the
fuse is interrupting a fault within the fuse’s current-limiting
range. Figure 1 illustrates this. Let-thru current is expressed
as a peak instantaneous value (lp).

Figure 3 illustrates the use of the peak let-thru current graph.
Assume that a 200 ampere Class J fuse (#AJT200) is to be
applied where the available fault current is 35,000 amperes
RMS. The graph shows that with 35,000 amperes RMS
available, the peak available current is 80,500 amperes
(35,000 x 2.3) and that the fuse will limit the peak let-thru
current to 12,000 amperes.

Time

Ip data is generally presented in the form of a graph. Let’s
review the key information provided by a peak let-thru graph.
Figure 2 shows the important components.
	
	
(1) 	The X-axis is labeled “Available Fault Current” in
		
RMS symmetrical amperes.
	
	
(2) 	 The Y-axis is labeled as “Instantaneous Peak Let-	
	 Thru Current” in amperes.
	
	
(3) 	 The line labeled “Maximum Peak Current Circuit
	 Can Produce” gives the worst case peak current 	
	 possible with no fuse in the circuit.
	
	
(4) 	 The fuse characteristic line is a plot of the peak let-	
	 thru currents which are passed by a given fuse at 	
	 various available fault currents.

Why is the peak available current 2.3 times greater than the
RMS available current? In theory, the peak available fault
current can be anywhere from 1.414 x (RMS available) to
2.828 x (RMS available) in a circuit where the impedance is
all reactance with no resistance. In reality all circuits include
some resistance and the 2.3 multiplier has been chosen as a
practical limit.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

P

Ip

www.barr-thorp.com

P33

Let-Thru Current and l2t
Ip versus I2t

Ip has a rather limited application usefulness. Two fuses can
have the same Ip but different total clearing times.
See Figure 4.

The fuse that clears in time A will provide better component
protection than will the fuse that clears in time B.
Fuse clearing I t takes into account Ip and total clearing
time. Fuse clearing I2t values are derived from oscillograms
of fuses tested within their current-limiting range and are
calculated as follows:
2

Fuse Let-Thru Tables
Apparent RMS Symmetrical Let-Thru
Current

Although the current-limiting characteristics of currentlimiting fuses are represented in Peak Let-Thru charts, an
increasingly easy to use method of presenting this data
uses Peak Let-Thru tables. The tables are based on Peak
Let-Thru charts and reflect fuse tests at 15% power factor
at rated voltage with prospective fault currents as high as
200,000 amperes. At each prospective fault current, let-thru
data is given in two forms for an individual fuse - lrms and
lp. Where lrms is the “Apparent RMS Symmetrical Current”
and lp is the maximum peak instantaneous current passed
by the fuse, the lp let-thru current is 2.3 times lrms. This
relationship exists between peak current and RMS available
current under worst-case test conditions (i.e. closing angle
of 0o at 15% power factor).
Let-thru tables are easier to read than let-thru charts.
Presenting let-thru data in table versus chart format reduces
the possibility of misreading the information and saves time.
These tables are also helpful when comparing the currentlimiting capability of various fuses.

The “t” in the equation is the total clearing time for the fuse.
To be proper, I2t should be written as (IRMS)2t. It is generally
understood that the “I” in I2t is really IRMS, and the RMS is
dropped for the sake of brevity.

Note, from Figure 4, since clearing time “B” is approximately
twice clearing time “A”, the resultant I2t for that fuse will be
at least twice the I2t for the fuse with clearing time “A” and
its level of protection will be correspondingly lower.
The I2t passed by a given fuse is dependent upon the
characteristics of the fuse and also upon the applied
voltage. The I2t passed by a given fuse will decrease as the
application voltage decreases. Unless stated otherwise,
published I2t values are based on AC testing. The I2t passed
by a fuse in a DC application may be higher or lower than in
an AC application. The voltage, available fault current and
time constant of the DC circuit are the determining factors.
Fuse I2t value can be used to determine the level of
protection provided to circuit components under fault current
conditions. Manufacturers of diodes, thyristors, triacs,
and cable publish I2t withstand ratings for their products.
The fuse chosen to protect these products should have a
clearing I2t that is lower than the withstand I2t of the device
being protected.

P34

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fuse Let-Thru Current Tables
Table 1- Class L, A4BQ Fuses at 600 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes

Short Circuit
Rms. Sym

601

800

1000

1200

1600

2000

2500

3000

4000

5000

6000

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

10,000

7.4

17

8.7

20

10

23

10

23

10

23

10

23

10

23

10

23

10

23

10

23

10

23

15,000

8.3

19

10

23

12

27

13

30

15

35

15

35

15

35

15

35

15

35

15

35

15

35

20,000

9.1

21

11

25

13

29

14

33

17

39

20

46

20

46

20

46

20

46

20

46

20

46

25,000

9.8

23

12

27

13

31

15

35

18

42

22

50

25

58

25

58

25

58

25

58

25

58

30,000

10

24

13

29

14

33

16

37

20

45

23

53

29

66

30

69

30

69

30

69

30

69

35,000

11

25

13

30

15

35

17

39

20

47

24

56

30

69

35

81

35

81

35

81

35

81

40,000

12

27

14

32

16

37

18

41

21

49

25

58

31

72

36

83

40

92

40

92

40

92

50,000

13

29

15

34

17

40

19

44

23

53

27

63

34

78

39

89

48

111

50

115

50

115

60,000

13

30

16

36

18

42

20

47

25

57

29

67

36

83

41

94

51

118

60

138

60

138

80,000

14

33

17

40

20

46

23

52

27

62

32

73

40

91

45

104

57

130

67

153

77

176

100,000

16

36

19

43

22

50

24

56

29

67

34

79

43

98

49

112

61

140

72

165

83

190

150,000

18

41

21

49

25

57

28

64

33

77

39

90

49

112

56

128

70

160

82

189

94

217

200,000

20

45

24

54

27

63

31

71

37

84

43

100

53

123

61

141

77

176

90

208

104

239

Table 2 - Class L, A4BY Fuses at 600 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes

Short Circuit
Rms. Sym

601

800

1000

1200

1600

2000

2500

3000

4000

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

15,000

11

24

13

29

15

35

15

35

15

35

15

35

15

35

15

35

15

35

20,000

12

26

14

32

16

37

19

43

20

46

20

46

20

46

20

46

20

46

25,000

13

29

15

34

18

40

20

46

24

55

25

58

25

58

25

58

25

58

30,000

13

30

16

36

19

43

21

49

25

58

29

67

30

69

30

69

30

69

35,000

14

32

17

38

20

45

23

52

27

61

30

70

33

76

35

81

35

81

40,000

15

34

17

40

21

47

24

54

28

64

32

73

35

79

37

86

40

92

50,000

16

36

19

43

22

51

25

58

30

68

34

78

37

86

41

95

50

115

60,000

17

38

20

45

24

54

27

62

31

72

37

84

40

91

44

100

53

121

80,000

18

42

22

50

26

59

29

67

35

80

40

92

44

100

48

110

58

133

100,000

20

45

24

54

28

64

32

73

38

87

43

99

47

108

52

119

62

143

150,000

23

52

27

62

32

73

37

84

43

99

49

113

54

123

59

137

73

167

200,000

25

56

29

67

35

80

40

91

48

110

54

123

59

136

65

150

79

181

Table 3 - Class L, A4BT Fuses at 600 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes

Rms. Sym

800

1000

1200

1600

2000

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

15,000

14

33

15

35

15

35

15

35

15

35

20,000

16

36

18

41

20

46

20

46

20

46

25,000

17

39

19

45

22

50

25

58

25

58

30,000

18

41

21

48

23

54

28

63

30

69

35,000

19

43

22

50

25

56

29

67

34

79

40,000

20

45

23

52

26

59

30

70

35

81

50,000

21

49

25

56

28

63

33

75

38

87

60,000

23

52

26

60

29

67

35

80

40

93

80,000

25

57

29

66

32

74

38

88

44

102

100,000

27

62

31

71

35

80

41

95

48

110

150,000

31

70

35

81

40

92

47

109

55

126

200,000

34

78

39

89

44

101

52

120

60

139

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

P

Short Circuit

www.barr-thorp.com

P35

Fuse Let-Thru Current Tables
Apparent RMS Symmetrical Let-Thru Current
Table 4 - Class RK1, A6K Fuses at 600 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes

Short Circuit
30

Rms. Sym

60

100

200

400

600

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

5,000

.63

1.4

1.4

3.2

2.0

4.6

3.2

7.4

4.6

11

5.0

11.5

10,000

.80

1.8

1.7

3.9

2.6

6.0

4.0

9.2

5.8

13

7.5

17

15,000

.91

2.1

2.0

4.6

2.9

6.7

4.6

11

6.7

15

8.6

20

20,000

1.0

2.3

2.2

5.1

3.2

7.4

5.0

12

7.4

17

9.5

22

25,000

1.1

2.5

2.4

5.5

3.5

8.1

5.4

12

7.9

18

10

23

30,000

1.2

2.6

2.5

5.8

3.7

8.5

5.8

13

8.4

19

11

25

35,000

1.2

2.8

2.6

6.0

3.9

9.0

6.1

14

8.9

20

11

26

40,000

1.3

2.9

2.8

6.4

4.1

9.4

6.3

14

9.3

21

12

27

50,000

1.4

3.1

3.0

6.9

4.4

10

6.8

16

10

23

13

30

60,000

1.4

3.3

3.2

7.4

4.7

11

7.3

17

11

24

14

32

80,000

1.6

3.7

3.5

8.1

5.1

12

8.0

18

12

27

15

35

100,000

1.7

3.9

3.7

8.5

5.5

13

8.6

20

13

29

16

37

150,000

2.0

4.5

4.4

9.9

6.3

14

9.9

23

14

33

19

43

200,000

2.2

4.9

4.7

11

7.0

16

11

25

16

37

20

47

Table 5 - Class RK1, A6D Fuses at 600 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes

Short Circuit
30

Rms. Sym

60

100

200

400

600

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

5,000

.80

1.8

1.5

3.5

2.0

4.6

3.5

8.0

5.0

12

-

-

10,000

1.0

2.3

1.9

4.4

2.5

5.8

4.4

10.1

7.1

16.4

10

23

15,000

1.2

2.7

2.2

4.9

2.9

6.6

5.0

11.6

8.2

18.8

12

27

20,000

1.3

2.9

2.4

5.4

3.1

7.1

5.5

12

9.0

20.7

13

29

25,000

1.4

3.2

2.6

5.9

3.4

7.8

6.0

13.8

9.7

22.3

14

32

30,000

1.5

3.4

2.7

6.2

3.6

8.3

6.3

14.6

10.3

23.6

15

33

35,000

1.5

3.5

2.9

6.6

3.8

8.7

6.7

15.4

10.8

24.9

15

35

40,000

1.6

3.7

3.0

6.9

4.0

9.1

7.0

16.5

11.3

26

16

37

50,000

1.7

4.0

3.2

7.4

4.3

9.8

7.5

16.5

12.2

28

17

40

60,000

1.8

4.2

3.4

7.8

4.5

11

8.0

17

13

30

18

42

80,000

2.0

4.7

3.8

8.6

5.0

12

8.8

20.3

13

33

20

46

100,000

2.2

5.0

4.1

9.3

5.4

12

9.5

20

14

35

22

50

150,000

2.5

5.8

4.6

11

6.1

14

10.9

25

16

40

25

57

200,000

2.8

6.3

5.1

12

6.8

16

11

25

19

45

27

63

Table 6 - Class J, A4J Fuses at 600 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes

Short Circuit
30

Rms. Sym

P36

60

100

200

400

600

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

5,000

.85

2.0

1.4

3.2

2.0

4.6

3.1

7.2

4.5

10

5.0

12

10,000

1.1

2.5

1.8

4.4

2.8

6.4

3.6

8.2

5.7

13

8.7

20

15,000

1.2

2.8

2.0

4.6

2.9

6.6

4.1

9.4

6.5

15

9.9

23

20,000

1.4

3.1

2.4

5.1

3.2

7.3

4.5

10

7.1

16

11

25

25,000

1.5

3.4

2.4

5.5

3.8

8.7

5.3

12

7.7

18

12

27

30,000

1.6

3.6

2.5

5.8

4.0

9.2

5.5

13

8.2

19

13

29

35,000

1.6

3.7

2.7

6.2

4.2

9.7

5.9

14

8.6

20

13

30

40,000

1.7

3.9

2.8

6.4

4.5

10

6.0

14

9.0

21

14

32

50,000

1.8

4.2

3.0

6.9

4.7

11

6.1

14

9.7

22

15

34

60,000

2.0

4.5

3.2

7.4

5.0

11

6.5

15

10

23

16

36

80,000

2.2

4.9

3.5

8.1

5.5

12

7.1

16

11

25

17

40

100,000

2.3

5.3

3.8

9.5

6.0

14

7.7

18

12

28

19

43

150,000

2.7

6.1

4.7

10.9

6.8

16

8.8

20

14

32

21

49

200,000

2.9

6.7

4.8

11

7.5

17

9.7

22

15

35

24

54

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fuse Let-Thru Current Tables
Apparent RMS Symmetrical Let-Thru Current
Table 7 - Class J, AJT Fuses at 600 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes

Short Circuit
30

Rms. Sym

60

100

200

400

600

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

5,000

.79

1.8

1.2

2.8

1.8

4.0

3.1

7.0

4.8

11

5.0

12

10,000

1.0

2.3

1.6

3.6

2.2

5.1

3.8

8.8

6.0

14

8.3

19

15,000

1.2

2.6

1.8

4.1

2.5

5.8

4.4

10

6.9

16

9.5

22

20,000

1.3

2.9

2.0

4.5

2.8

6.4

4.8

11

7.6

18

11

24

25,000

1.4

3.1

2.1

4.8

3.0

6.9

5.2

12

8.2

19

11

26

30,000

1.4

3.3

2.2

5.1

3.2

7.4

5.5

13

8.7

20

12

28

35,000

1.5

3.5

2.4

5.4

3.4

7.7

5.8

13

9.1

21

13

29

40,000

1.6

3.7

2.5

5.6

3.5

8.1

6.1

14

9.6

22

13

30

50,000

1.7

3.9

2.7

6.1

3.8

8.7

6.6

15

10.3

24

14

33

60,000

1.8

4.2

2.8

6.4

4.0

9.2

7.0

16

11

25

15

35

80,000

2.0

4.6

3.1

7.1

4.4

10

7.7

18

12

28

17

38

100,000

2.2

4.9

3.3

7.6

4.8

11

8.3

19

13

30

18

41

150,000

2.5

5.7

3.8

8.7

5.4

12

9.5

22

15

34

21

47

200,000

2.7

6.2

4.2

9.7

6.0

14

10.4

24

16

37

23

59

Table 8 - Class T, A6T Fuses at 600 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes

Short Circuit
30

Rms. Sym

60

100

200

400

600

800

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

5,000

.62

1.4

1.2

2.8

1.6

3.8

2.6

6.0

4.2

9.7

5.0

12

5.0

12

10,000

.78

1.8

1.5

3.5

2.1

4.8

3.3

7.5

5.3

12

8.2

19

10

22

15,000

.89

2.1

1.7

4.0

2.4

5.4

3.7

8.6

6.1

14

9.4

22

11

26

20,000

.98

2.3

1.9

4.4

2.6

6.0

4.1

9.5

6.7

15

10

24

12

28

25,000

1.1

2.4

2.0

4.8

2.8

6.5

4.4

10

7.2

17

11

26

13

31

30,000

1.1

2.6

2.2

5.0

3.0

6.9

4.7

11

7.7

18

12

27

14

32

35,000

1.2

2.7

2.3

5.3

3.1

7.2

5.0

11

8.1

19

12

29

15

34

40,000

1.2

2.9

2.4

5.6

3.3

7.5

5.2

12

8.5

19

13

30

16

36

50,000

1.3

3.1

2.6

6.0

3.5

8.1

5.6

13

9.1

21

14

32

17

38

60,000

1.4

3.3

2.8

6.4

3.8

8.6

5.9

14

9.7

22

15

34

18

41

80,000

1.6

3.6

3.0

7.0

4.1

9.5

6.5

15

11

25

16

38

20

45

100,000

1.7

3.9

3.2

7.5

4.5

10

7.0

16

11

26

18

40

21

48

150,000

1.9

4.4

3.8

8.6

5.1

12

8.1

19

13

30

20

46

24

55

200,000

2.1

4.9

4.1

9.5

5.6

13

8.9

20

14

33

22

51

27

61

Table 9 - Class T, A3T Fuses at 300 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes
30

Rms. Sym

60

100

200

400

600

800

1200

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

5,000

.53

1.2

.95

2.2

1.4

3.1

2.0

4.6

3.0

6.9

4.5

10

5.0

12

5.0

12

10,000

.66

1.5

1.2

2.8

1.7

3.9

2.5

5.8

3.8

8.7

5.6

13

7.2

16

9.3

21

15,000

.76

1.7

1.4

3.2

2.0

4.5

2.9

6.6

4.4

10

6.4

15

8.2

19

11

24

20,000

.83

1.9

1.5

3.5

2.1

4.8

3.1

7.1

4.8

11

7.0

16

9.0

21

12

27

25,000

.90

2.1

1.6

3.7

2.3

5.3

3.4

7.8

5.2

12

7.6

17

9.7

22

13

29

30,000

.96

2.2

1.7

3.9

2.5

5.6

3.6

8.3

5.5

13

8.1

19

10

24

13

31

35,000

1.0

2.3

1.8

4.1

2.6

6.0

3.8

8.7

5.8

13

8.5

20

11

25

14

32

40,000

1.1

2.4

1.9

4.4

2.7

6.2

4.0

9.2

6.0

14

8.9

20

11

26

15

34

50,000

1.1

2.6

2.1

4.7

2.9

6.7

4.3

9.9

6.5

15

9.6

22

12

28

16

37

60,000

1.2

2.8

2.2

5.1

3.1

7.1

4.5

10

6.9

16

10

23

13

30

17

39

80,000

1.3

3.1

2.4

5.5

3.4

7.8

5.0

12

7.6

17

11

26

14

33

19

43

100,000

1.4

3.3

2.6

6.0

3.7

8.4

5.4

12

8.2

19

12

28

15

35

20

46

150,000

1.6

3.7

3.0

6.8

4.2

9.7

6.1

14

9.4

22

14

32

18

41

23

53

200,000

1.8

4.1

3.3

7.5

4.6

11

6.8

16

10

24

15

35

19

45

25

58

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P

Short Circuit

P37

Fuse Let-Thru Current Tables
Apparent RMS Symmetrical Let-Thru Current
Table 10- Class RK1, A2K Fuses at 250 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes

Short Circuit
30

Rms. Sym

60

100

200

400

600

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

5,000

.61

1.4

1.4

3.2

1.7

4.0

2.9

6.7

4.4

10

5.0

12

10,000

.77

1.8

1.7

4.0

2.2

5.0

3.7

8.5

5.5

13

7.4

17

15,000

.88

2.0

2.0

4.6

2.5

5.8

4.2

9.7

6.3

14

8.5

19

20,000

.97

2.2

2.2

5.0

2.8

6.3

4.6

11

6.9

16

9.3

21

25,000

1.1

2.4

2.4

5.4

3.0

6.8

5.0

12

7.4

17

10

23

30,000

1.1

2.6

2.5

5.8

3.2

7.3

5.3

12

7.9

18

11

25

35,000

1.2

2.7

2.6

6.0

3.3

7.7

5.6

13

8.3

19

11

26

40,000

1.2

2.8

2.8

6.3

3.5

8.0

5.9

13

8.7

20

12

27

50,000

1.3

3.0

3.0

6.8

3.8

8.6

6.3

14

9.4

22

13

29

60,000

1.4

3.2

3.2

7.2

4.0

9.2

6.7

15

10

23

13

31

80,000

1.5

3.5

3.5

8.0

4.4

10

7.4

17

11

25

15

34

100,000

1.7

3.8

3.7

8.6

4.7

11

7.9

18

12

27

16

37

150,000

1.9

4.4

4.3

9.8

5.4

12

9.1

21

14

31

18

42

200,000

2.1

4.8

4.7

11

6.0

14

10

23

15

34

20

46

Table 11 - Class RK1, A2D Fuses at 250 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes

Short Circuit
30

Rms. Sym

60

100

200

400

600

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

5,000

.77

1.8

1.4

3.2

2.0

4.6

3.2

7.3

5.0

12

5.0

12

10,000

.97

2.2

1.8

4.0

2.5

5.8

4.0

9.2

6.4

15

8.0

18

15,000

1.1

2.6

2.0

4.6

2.9

6.6

4.6

11

7.3

17

9.2

21

20,000

1.2

2.8

2.2

5.1

3.2

7.3

5.0

12

8.1

19

10

23

25,000

1.3

3.0

2.4

5.5

3.4

7.9

5.4

12

8.7

20

11

25

30,000

1.4

3.2

2.5

5.8

3.6

8.3

5.8

13

9.2

21

12

27

35,000

1.5

3.4

2.7

6.1

3.8

8.8

6.1

14

9.7

22

12

28

40,000

1.5

3.5

2.8

5.7

4.0

9.2

6.4

15

10

23

13

29

50,000

1.7

3.8

3.0

6.9

4.3

9.9

6.8

16

11

25

14

32

60,000

1.8

4.0

3.2

7.3

4.6

11

7.3

17

12

27

15

34

80,000

1.9

4.5

3.5

8.1

5.0

12

8.0

18

13

29

16

37

100,000

2.1

4.8

3.8

8.7

5.4

12

8.6

20

14

32

17

40

150,000

2.4

5.5

4.3

9.9

6.2

14

9.9

23

16

36

20

46

200,000

2.6

6.0

4.8

11

6.8

16

11

25

17

40

22

50

Table 12 - Class RK5, TRS Fuses at 600 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes

Short Circuit
30

Rms. Sym

P38

60

100

200

400

600

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

5,000

1.7

3.9

3.2

7.4

3.4

7.8

5.0

12

-

-

-

-

10,000

2.1

4.8

4.0

9.2

4.2

9.7

6.2

14

10

23

10

23

15,000

2.4

5.5

4.6

11

4.8

11

7.1

16

12

27

15

35

20,000

2.7

6.2

5.1

12

5.3

12

7.8

18

13

30

18

42

25,000

2.9

6.7

5.5

13

5.7

13

8.4

19

14

32

20

45

30,000

3.1

7.1

5.8

13

6.1

14

8.9

20

15

35

21

48

35,000

3.3

7.6

6.1

14

6.4

15

9.4

22

16

36

22

50

40,000

3.4

7.8

6.4

15

6.7

15

9.8

23

17

38

23

53

50,000

3.7

8.5

6.9

16

7.2

17

11

24

18

41

25

57

60,000

3.9

9.0

7.3

17

7.7

18

11

26

19

43

26

60

80,000

4.3

9.9

8.1

19

8.5

20

12

29

21

48

29

66

100,000

4.6

11

8.7

20

9.1

21

13

31

22

52

31

72

150,000

5.3

12

9.9

23

10

24

15

35

26

59

36

82

200,000

5.8

13

11

25

12

26

17

39

28

65

39

90

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Fuse Let-Thru Current Tables
Apparent RMS Symmetrical Let-Thru Current
Table 13 - Class RK5, TR Fuses at 250 Volts AC, 15% Power Factor
Fuse Let-Thru Current In Kilo-Amperes

Prospective

By Fuse Rating In Amperes

Short Circuit
30

Rms. Sym

60

100

200

400

600

Amperes

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

irms

lp

5,000

1.4

3.2

3.0

6.9

3.2

7.4

5.0

12

-

-

-

-

10,000

1.8

4.1

3.8

8.7

4.1

9.4

6.6

15

10

23

10

23

15,000

2.1

4.8

4.4

10

4.7

11

7.6

17

13

29

15

35

20,000

2.3

5.3

4.8

11

5.1

12

8.4

19

14

32

19

44

25,000

2.5

5.6

5.2

12

5.5

13

9.0

21

15

34

21

48

30,000

2.6

6.0

5.5

13

5.9

14

9.6

22

16

37

22

50

35,000

2.7

6.2

5.8

13

6.2

14

10

23

17

38

23

53

40,000

2.9

6.7

6.1

14

6.5

15

11

24

18

40

24

56

50,000

3.1

7.1

6.5

15

7.0

16

11

26

19

43

26

60

60,000

3.3

7.6

7.0

16

7.4

17

12

27

20

46

28

63

80,000

3.6

8.3

7.7

18

8.1

19

13

31

22

51

30

70

100,000

3.9

9.0

8.3

19

8.8

20

14

33

24

55

33

75

150,000

4.4

10

9.4

22

10

23

16

38

27

62

38

86

200,000

4.9

11

11

24

11

26

18

41

30

69

41

95

Bus Duct Short-Circuit Protection

The following table shows the potential short-circuit
current ratings for both feeder and plug-in bus duct.
Also shown are the peak instantaneous currents the
bus duct must be capable of withstanding to earn a
given “short-circuit current rating”.
Current-limiting fuses may be used to protect bus duct
from fault currents that exceed the bus duct “shortcircuit current rating”. The fuse will provide short-circuit
protection if fuse peak let-thru current does not exceed
the bus duct peak instantaneous withstand current. In
addition, the fuse total clearing curve must fall to the
left of the bus duct short-circuit current rating at the 3
cycle (.05 sec.) point. The fuse ampere ratings shown
in this table satisfy both of these requirements.

Example:

In a 480V circuit with 100,000A available short-circuit
current, what maximum size fuse can be used to
protect feeder bus duct which has a 42,000 shortcircuit rating?

Answer:

From the table, a Mersen 1600A Class L fuse
A4BQ1600 will protect this bus duct up to 100,000
amperes.

Feeder & Plug-In

Maximum Mersen Fuse for

Fuse Bus Duct

Short Circuit Protection*

Peak Instantaneous
Withstand Current in
Amperes

50,000A

100,000A 200,000A

5000

8500

60A

60A

30A

7500

13,000

100A

100A

100A

10,000

17,000

200A

100A

100A

14,000

28,000

400A

400A

200A

22,000

48,000

800A

600A

400A

25,000

55,000

1000A

600A

600A

30,000

66,000

1200A

800A

600A

35,000

76,000

1600A

1000A

800A

42,000

92,000

2500A

1600A

1000A

50,000

110,000

3000A

2000A

1200A

65,000

142,000

4000A

3000A

2500A

75,000

160,000

5000A

4000A

3000A

85,000

180,000

5000A

5000A

4000A

100,000

220,000

6000A

6000A

5000A

125,000

270,000

6000A

6000A

6000A

150,000

330,000

6000A

6000A

6000A

Short Circuit Current
Rating in Amperes

*	 30A to 600A fuses – 	

Class J (time delay AJT)

		

Class RK1 (A2K/A6K or time delay A2D/A6D)

	 800 to 6000A fuses –	

Class L (A4BQ)

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P

Bus duct listed to the UL 857 standard is labeled with
a “short-circuit current rating”. To earn this rating the
bus duct must be capable of surviving its “short-circuit
current rating” for 3 full cycles (60 Hz basis).

P39

Capacitor Protection
The primary responsibility of a capacitor fuse is to isolate
a shorted capacitor before the capacitor can damage
surrounding equipment or personnel. Typical capacitor
failure occurs when the dielectric in the capacitor is
no longer able to withstand the applied voltage. A low
impedance current path results. The excessive heat
generated builds pressure and can cause violent case
rupture. A fuse will isolate the shorted capacitor before case
rupture occurs.

Fuse Placement

The Code requires that an overcurrent device be placed
in each ungrounded conductor of each capacitor bank
(see Figure 1). The Code further requires that the rating or
setting of the over-current device be as low as practicable. A
separate overcurrent device is not required if the capacitor is
connected on the load side of a motor-running
overcurrent device.
Fusing per the Code provides reasonable protection if the
capacitors are the metallized film self-healing type. If not,
each capacitor should be individually fused as shown in
Figure 2.

For applications over 600V to 5.5kV, we suggest Amp-Trap
A100C to A550C capacitor fuses. These medium voltage
fuses are available in a variety of voltage ratings and
mounting configurations. Refer to pages E36 for specific
data. Medium voltage capacitor fuses are sized at 165% to
200% of the capacitor current rating.
Capacitor fuses are selected for their ability to provide short
circuit protection and to ride through capacitor inrush current.
Inrush current is affected by the closing angle, capacitance,
resistance and inductance of the circuit, and varies from one
application to another. Inrush lasts for less than 1/4 cycle
and is typically less than 25 timess the capacitor’s current
rating.
Steady state capacitor current is proportional to the applied
voltage and frequency. Since voltage and frequency are
fixed in power factor correction applications, the capacitor
is not expected to be subjected to an overload. Therefore,
capacitor fuses are not selected to provide overload
protectors for the capacitor.

Fusing each individual capacitor is especially important in
large banks of parallel capacitors. Should one capacitor
fail, the parallel capacitors will discharge into the faulted
capacitor and violent case rupture of the faulted capacitor
can result. Individual capacitor fusing eliminates this
problem.
If the capacitors are to be placed in banks comprised of both
series and parallel combinations, the capacitor manufacturer
must be consulted for fuse placement recommendations.
The opening of improperly placed fuses can cause
overvoltage and result in damage to other capacitors in the
network.

Ampere Rating

How much overcurrent can a capacitor withstand? What
effects do neighboring capacitors have on the inrush of
a given capacitor? These and other questions influence
fuse selection. Circuit analysis can be very complex. It
is best to consult the capacitor manufacturer for specific
recommendations.
For applications 600V or less in lieu of specific fusing
recommendations from the capacitor manufacturer, we
suggest a Mersen A60C Type 121 or an A6Y Type 2SG
fuse sized at 165% to 200% of the capacitor’s current rating
(contact factory for technical data). If these fuses are not
dimensionally acceptable, then a non-time delay Class J or
Class RK1 fuse could be used and sized at 185% to 220%
of the capacitor’s current rating.

P40

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Capacitor Protection
kVAR vs. AMPS
The capacitor’s current rating can be derived from its kVAR
rating by using the following formula:
kVAR x 1000 = amps
volts			

1 kVAR = 1000VA (Reactive)

Example#1: What fuse would you recommend for a three
phase capacitor rated 100kVAR at 480 volts?
100,000 volt-amps = 208 amps
480 volts

Example#2: What fuse would you recommend for a three
phase capacitor rated 2400kV, 100kVAR?

Calculate Capacitor Current = 100,000 volt-amps = 24A

√ 3 x 2400V
fuse size 24 x 1.65 = 39A
	

24 x 2.00 = 48A

We suggest a 40 or 50 amp fuse rated at least 2400V
A250C50-XX, where XX is the type of mounting needed.

To determine line current, we must divide the 208 amps,
which is the three phase current by √ 3
208 = 120 amps
√3
If an A6OC Type 121 fuse is to be used, size the fuse at
165% to 200% of line current.
120 amps x 1.65 = 198 amps
120 amps x 2.00 = 240 amps
Suggestions: A60C200-121 or A60C200-121TI

If a Class J or a Class RK1 is to be used, size the fuse at
185% to 220% of line current.
120 amps x 1.85 = 222 amps
120 amps x 2.20 = 264 amps

P

Suggestions: A4J225 or A6K225R

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P41

Cable Protection
Using Cable Protectors

Placement of Cable Protectors

Cable Protectors are special purpose limiters which are used
to protect service entrance and distribution cable runs. The
National Electrical Code (NEC) does not require using
cable protectors.

In single phase applications where a single transformer
supplies the service and there are only one or two
conductors per phase, a single Cable Protector per cable
may be used. The Cable Protector should be located at
the supply end of the cable. In all other applications, Cable
Protectors should be placed at both ends of each cable.
This allows a faulted cable to be isolated from the source
end and from a back feed at its load end. Isolation of a
faulted cable is only possible if there are 3 or more parallel
cables per phase.

When unprotected cables are paralleled, a singe conductor
faulting to ground can result in damage to and eventual
loss of all parallel conductors. The resultant cost of cable
replacement, loss of service, and down time can be
significant. This cost can be minimized by the use of
Cable Protectors.
When each phase consists of three or more parallel
conductors, Cable Protectors are installed at each end of
each conductor. Should one cable fault, the Cable Protectors
at each end of the faulted cable will open and isolate the
faulted cable. The unfaulted cables will maintain service.

Terminations
In addition to improving system reliability, Cable Protectors
provide a means of terminating cable, thus eliminating the
need for cable lugs. Cable Protectors are available with the
following configurations:
Aluminum and copper cable require different terminations.
Cable Protectors intended for copper cable must not be
used with aluminum cable. Cable Protectors intended for
aluminum cable include an oxide inhibitor.

Type 1
Type 3
Type 5
Type 6
Type 8

P42

Cable Protector Ampacity
Cable Protectors are not ampere rated. They are not
intended to provide overload protection for the cable. Cable
Protectors are designed to open in case of a short circuit
or after a cable has faulted. Thus total system reliability is
maximized. For these reasons Cable Protectors are rated
in terms of the cable material (aluminum or copper) and the
cable size (250kcmil, 500kcmil, etc.)

Selecting a Cable Protector
The following questions must be answered to choose the
correct Cable Protector:
•	 Is the cable copper or aluminum?
•	 What is the cable size?
•	 What termination type is desired?
•	 Is the Cable Protector to be insulated or protected with a
heat-shrink sleeve or a rubber boot?
Once these questions have been answered, the Cable
Protector catalog number can be chosen from the listings.

Small Cable Sizes
Class J fuses may be used for cable sizes smaller than
4/0. Since Class J blades are drilled for bolting, they may
be attached directly to bus. Cables must be prepared by
installing lugs before bolting to the fuse. Cable-to-bus or
cable-to-cable terminations are possible. The following
ampere ratings are recommended, or each cable size.
Cable - Size Awg CU or AL

Class J Fuse Catalog No.

#4

A4J125

#3

A4J150

#2

A4J175

#1

A4J200

1/0

A4J250

2/0

A4J300

3/0

A4J400

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Welder Protection
General

Special Applications

Articles 630-12 and 630-32 of the National Electrical Code

UL class fuses sized according to the Code may not

requires that electric welders and their supply conductors

be suitable in some welding applications. High ambient

have overcurrent protection. The Code further requires that

temperatures, high cycle rates and high available fault

each welder have a nameplate which provides information

currents may require the use of Mersen Welder Protectors.

necessary for the selection of the appropriate supply conductors and overcurrent protection devices.

Welder Protectors (A4BX Type 150 or Type 150J) are special
purpose limiters which have been designed specifically for

While either circuit breakers or fuses may be used for over-

welding applications to protect equipment in case of short

current protection, the typically high available fault currents

circuits. They have twice the thermal rating of UL Class fuses

and the need for overall system selective coordination favor

yet provide a low clearing I2t . This combination minimizes

the use of current-limiting fuses.

fuse fatigue and allows effective coordination with upstream
devices. Welder Protectors may be sized closer to welder

Supply Conductor Protection

primary ampere rating than UL Class fuses, hence may allow

For AC transformer, DC rectifier and motor-generator arc

the use of smaller disconnect switches.

welders the supply conductors should be fused at not more
than 200% of the conductor ampere rating. For resistance

Welder Protectors are intended for short circuit protection

welders the Code allows fusing at up to 300% of conductor

and are not intended for overload protection. They should

ampere rating. In both applications a time delay RK5 fuse

never be used as the only protective device on any welder

such as the Tri-onic is generally recommended.

application. Thermal overload protection must be provided in

®

the welder by some other device.

Welder Protection
To comply with the Code, AC transformer, DC rectifier and
motor-generator arc welders should be fused at not more
than 200% of their primary current rating (shown on welder
nameplate). Resistance welders should be fused at not more
than 300% of their primary current rating. As with supply
conductors, RK5 time delay fuses such as the Tri-onic® are
recommended. It should be noted that the Code states that
a separate overcurrent device is not required for the welder
if the supply conductors are protected by an overcurrent
device which will satisfy the welder overcurrent

P

protection requirements.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P43

Motor Starter General Information
Typical Construction Of a Motor Starter
Disconnect Switch
UL 98 - UL489
CSA – C22.2 # 4
CSA – C22.2 # 5
Fuses

SIRCO
Non-Fusible
Disconnect Switch
range

FUSERBLOC
Fusible Disconnect Switch
range

Contactor
Overload relay
UL 508 Manual Motor Controller
“Suitable as Motor Disconnect”
CSA – C22.2 # 14

FSLBS Non-Fusible
Disconnect Switch range

Motor

Essential parts of a motor branch circuit
required by the National Electrical Code:

Motor-controller

•• Disconnect means

motor according to the National Electrical Code article 430.82.

•• Branch-circuit short-circuit protective device

Any switch or device that is normally used to start and stop a

•• Motor-controller

Motor overload protective devices

•• Motor overload protective devices

The National Electrical Code permits fuses to be used as
the sole means of overload protection for motor branch

Disconnect means

circuits. This approach is often practical only with small single

The Disconnect means can be a Manual Disconnect Switch

phase motors. Most integral horsepower 3 phase motors are

according to UL 98.

controlled by a motor starter which includes an overload relay.
Since the overload relay provides overload protection for the

A manual Motor Controller (according to UL 508) ­additio­nally

motor branch circuit, the fuses may be sized for short-

marked “Suitable as Motor Disconnect” is only permitted as

circuit protection.

a disconnecting means where installed between the final
branch-circuit short-circuit and ­ground-fault protective device
and the motor (NEC 2008 Article 430.109).

Branch-circuit short-circuit
protective device
The short-circuit protective device can be either a Fuse or
an Inverse-time Circuit-breaker.

P44

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Product Features

of Non-Fusible & Fusible Disconnect Switches
Door Interlock in On Position

Touch Safe
Our design reduces or

The handles allow opening

­eliminates the danger of

the door in the OFF position

­accidental contact with live,

only. In the ON position the

energized parts. All products

door can not be ­opened.

are supplied standard with
line side shrouding.

This interlocking can be
by-passed by authorized
personnel (defeater option

Positive Opening Operation

on handle) for maintenance,

The positive opening

testing or ­commissioning.

ope­ration feature of our
switches means that all the
main contacts are ensured to

Defeater

be in the open position when
the handle is in the
The defeat function allows

“OFF” position.

qualified ­personnel to
by-pass the door interlock
when the switch is in the ON
­position by means of a tool.

New NFPA 79 Requirements and Solutions
As defined in the NFPA 79

This exclusive design is also

Standard section 5.3.3.1 and

available in a NEMA 4 and

6.2.3.2, our disconnecting

4X rating.

devices fully comply
with all of the following

Padlocking

requirements:
1.	Isolate the electrical equipment from the supply circuit and	
Handles can be padlocked

have one off (open) and one on (closed) position only.

in the OFF position with up

2. Have an external operating means (e.g., handle).

to 3 padlocks. Meets OSHA

3. Be provided with a permanent means permitting it to be

requirement for lockout /

locked in the off (open) position only (e.g., by padlocks)

tagout.

independent of the door position. When so locked, remote
as well as local closing shall be prevented.

can not be opened when the
handle is padlocked.

4. Be operable, by qualified persons, independent of the door
position without the use of accessory tools or devices.
However the closing of the disconnecting means while door 	
is open is not permitted unless an interlock is ­ope­rated by 	

P

For safety reasons, the door

deliberate action.
Flange and side operation:
Our side operated switches used with flange handles meet the
requirements of the NFPA 79 without any additional parts
being added.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P45

Product Features

of Non-Fusible & Fusible Disconnect Switches
Welded Contact Protection

Contact Principle

Positive opening operation

Up to 400A

safeguards users in case

All switches use silver

of welded contacts due to

tipped contacts technology

an overload or short-circuit.

­provi­ding the following

The handle can not reach

advantages:

the “OFF” position unless
the contacts are truly open.

•• best solution for harsh

According to the IEC 947-3

environments (humidity,

standard if the contacts are

sulphide, chloride…),

welded due to an overload

•• high on-load break

or short-circuit, the switch

­characteristics,

will not reach the “OFF”

•• longer mechanical and

­position and can not be

electrical life,

padlocked in this position

•• maintenance free

as long as operating force

switches without grease.

applied to the operating
mechanism is less than

Above 400A

a force three times the

Our switches use a self-

­standard operating force.

­cleaning moving contact

Thus, this unusual opera-

technology allowing high

tion alerts the user that a

short-circuit withstand.

­pro­blem has occurred.

Clear Position Indicator

Tailor-Made Solutions

All switches and handles

•• Multipolar switches

have clear “ON” and “OFF”

(examples: 12-pole 160A

designations.

switch; 18-pole 30A
switch…).
•• Rear connections (top
or/and bottom).
•• Mixed pole (example:

Fast Make and Break Contacts

3-pole 200A + 2-pole

All the Non-Fusible and Fusible Disconnect switches’

Please consult us.

30A switch…).

contacts work independently of the speed and force of the
operator providing better electrical characteristics (making
capacities on short-circuits, highly inductive load operation
possibilities).

P46

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Product Features of Fusible Disconnect Switches
Exceptional 200kA short-circuit protection
with fuses

Practical safeguard

Double break

The Fused Switch line
with class CC, J or L fuses
provides exceptional
high level of short-circuit
protection, up to 200kA.
Fuse

Circuit breaker

The CC and J fuses are
more current limiting than
older classes of fuses or
circuit breakers. In other
words, fuses have higher
breaking capacities than
most of the circuit breakers.
Moreover discrimination
(selectivity) and coordination
are easily achieved
with fuses.
The fuse solution brings the
following advantages: high
performance, reliability,
safety, savings and ease
of use.

Arc broken into 4
1

This feature allows the
switch to operate on highly
inductive loads.
2

Switch with
older fuse classes

Panel

4

Touch safe

Panel space saving

Fusible
­disconnect
switch

3

The modern designed
mecha­nism of our Fusible
Disconnect Switches
disconnects both sides of
the fuses using two double
breaking contacts per pole.
This ensures the complete
isolation of the fuses in the
“OFF” position and allows
the switch to be fed from
either top or bottom side.

This proven switch
techno­logy has the fuses
incorporated on the top
of the switch mechanism
to reduce the footprint of
the product and save you
­valuable real estate in
your panel.

Our design reduces or
­eliminates the danger of
­accidental contact with live,
energized parts.
All switches are supplied
­standard with fuse cover and
line side shrouding.

The space saving can be
as much as 50% from the
switches designed with use
of older fuse classes.

Fast and safe commissioning
P

The TEST feature enables
the testing of the control
circuit auxiliaries without
switching the main contacts
or remo­ving the fuses.
This function provides
a ­serious technical and
commercial alternative to a
separately wired push button.
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P47

Correction Factors

For Non-Fusible & Fusible Disconnect Switches
Correction factors due to ambient air temperature
Method: lthu ≤ lth x Kt
ta: ambient temperature
Ith: thermal switch current
Kt: correction factor due to ambient temperature ta
Ithu: maximum thermal current after correction

Non-Fusible Disconnect Switches

Fusible Disconnect Switches

T (° C)

T (° C)

Ith

40°C < ta ≤ 50°C

50°C < ta ≤ 60°C

60°C < ta ≤ 70°C

Ith

40°C < ta ≤ 50°C

50°C < ta ≤ 60°C

60°C < ta ≤ 70°C

V30 A

1

0.8

0.7

30 A CC CD type

0.9

0.8

0.7

V60 A

1

1

1

30A J CD type

0.9

0.8

0.7

V100 A

1

1

1

30 A CC

1

1

1

V200 A

1

1

0.9

30 A J

1

1

1

V400 A

1

0.9

0.8

60 A J

1

1

1

400 A

1

1

1

100 A J

1

1

1

600 A

1

1

0.9

200 A J

1

1

1

800 A

1

1

1

400 A J

0.9

0.8

0.7

1000 A

1

1

0.9

600 A J

1

1

1

1200 A

1

0.9

0.8

800 A L

1

1

1

Correction factors due to frequency
Method: lthu ≤ lth x Kf
f: rated operating frequency
Ith: thermal switch current
Kf: correction factor due to operating frequency F
Ithu: maximum thermal current after correction

Non-Fusible Disconnect Switches

Fusible Disconnect Switches

f (Hz)
Ith

P48

f (Hz)

100 Hz < f ≤ 2000 Hz

2000 Hz < f ≤ 6000 Hz

6000 Hz < f ≤ 10000 Hz

Ith

100 Hz < f ≤ 2000 Hz 2000 Hz < f ≤ 6000 Hz 6000 Hz < f ≤ 10000 Hz

V30 A

1

0.7

0.6

30 A CC CD type

0.8

0.7

0.6

V60 A

1

1

1

30 A J CD type

0.8

0.7

0.6

V100 A

1

1

1

30 A CC

1

1

1

V200 A

1

1

1

30 A J

1

1

1

V400 A

0.9

0.8

0.7

60 A J

1

1

1

400 A

1

1

1

100 A J

1

1

1

600 A

1

0.9

0.8

200 A J

1

0.9

0.8

800 A

1

1

0.9

400 A J

0.8

0.7

0.6

1000 A

1

0.9

0.8

600 A J

1

1

1

1200 A

1

0.7

0.6

800 A L

1

1

1

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Auxiliary Contacts
Auxiliary Contact Wiring Diagrams

Auxiliary contact rating codes (according to UL508 standard item 139)

Designation

Example
A600

max load
(volt-ampere)

A contactor used at 600VAC - 60 Hz has the following
specifications:
max operating voltage
(volt)

Average consumption: - inrush 60 Hz: 1200VA
- sealed 60 Hz: 120VA

These codes concern the auxiliary contacts and give the
maximum load they can make or break. The numerical suffix
designates the maximum voltage design values, which are
to be 600, 300 and 150 volts for suffixes 600, 300 and 150
respectively. The table below gives some typical
rating codes:

Contact Rating Code

Thus a C600 rated auxiliary device is the minimum
rating required.

Network Type

Making Max Load (VA)

Breaking Max Load (VA)

A600

600

AC

7200

720

B600

600

AC

3600

360

C600

600

AC

1800

180

D300

300

AC

432

72

E150

150

AC

216

36

N600

600

DC

275

275

P600

600

DC

138

138

Q600

600

DC

69

69

R300

300

DC

28

28

P

Max Operating Voltage (V)

Designation

Note: A600 and N600 are the highest categories and may be used to cover all cases.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P49

NEMA Ratings & IP Cross-Reference
This table provides a guide for converting from NEMA Enclosure Type Numbers to IP Ratings. The NEMA Types meet or exceed
the test requirements for the associated European Classifications; for this reason the table should not be used to convert “from IP
Rating to NEMA” and the “NEMA to IP Rating” should be verified by test.
NEMA Type
1
2
3
3R
3S
4
4X
6
6P
12
12K

Intended Use and Description

NEMA Ratings and IP Cross-Reference

Indoor use primarily to provide a degree of protection against contact with the enclosed equipment and against a
limited amount of falling dirt.
Indoor use to provide a degree of protection against a limited amount of falling water and dirt.
Intended for outdoor use primarily to provide a degree of protection against rain, sleet, windblown dust, and
damage from external ice formation.
Intended for outdoor use primarily to provide a degree of protection against rain, sleet, and damage from external
ice formation.
Intended for outdoor use primarily to provide a degree of protection against rain, sleet, windblown dust, and to
provide for operation of external mechanisms when ice laden.
Intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain,
splashing water, hose-directed water, and damage from external ice formation.
Intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and
rain, splashing water, hose-directed water, and damage from ice formation.
Intended for indoor or outdoor use primarily to provide a degree of protection against hose-directed water, the entry
of water during occasional temporary submersion at a limited depth, and damage from external ice formation.
Intended for indoor or outdoor use primarily to provide a degree of protection against hose-directed water, the entry
of water during prolonged submersion at a limited depth, and damage from external ice formation.
Intended for indoor use primarily to provide a degree of protection against circulating dust, falling dirt, and dripping
non-corrosive liquids.
Type 12 with knockouts.

NEMA 1 meets or exceeds IP10
NEMA 2 meets or exceeds IP11
NEMA 3 meets or exceeds IP54
NEMA 3R meets or exceeds IP14
NEMA 3S meets or exceeds IP54
NEMA 4 meets or exceeds IP56
NEMA 4X meets or exceeds IP56
NEMA 6 meets or exceeds IP67
NEMA 6P meets or exceeds IP67
NEMA 12 meets or exceeds IP52
NEMA 12K meets or exceeds IP52

Wire Size Cross Reference

P50

AWG

mm2

kcmil/mcm

mm2

14

2.1

250

127

12

3.3

300

152

10

5.3

350

177

8

8.4

400

203

6

13.3

500

253

4

21.2

600

304

3

26.7

700

355

2

33.6

750

380

1

42.4

800

405

1/0

53.5

900

456

2/0

67.4

1000

507

3/0

85.0

1250

633

4/0

107.2

1500

760

1750

887

2000

1014

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Degrees of Protection

(IP Codes According to IEC 60529 Standard)
The degrees of protection are defined by two numbers and sometimes by an additional letter.
For example: IP 55 or IP xx B (x indicates: any value).
The numbers and additional letters are defined below:

IP

0

First Number

Second Number

Protection Against Solid Body Penetration

Protection Against Liquid Penetration

Tests

IP

No protection

bodies greater than

2

(1)

3

0

4

Protected against water
1

drops falling vertically

Protected against water
2

drops falling up to 15°

12 mm

from the vertical

Protected against solid

Protected against water
3

showers up to 60° from

2.5 mm

the vertical

Protected against solid

Protected against water
4

splashes from any

mm	

direction

Protected against dust

Protected against water

(excluding damaging

5

deposits)

Total protection against

6

No protection

Protected against solid

bodies greater than 1

5

Description

(condensation)

bodies greater than

dust

Protection
Brief

50 mm

bodies greater than

Degree of

Letter(2)

Tests

Protected against solid
1

Additional

Protected against
A

access with back
of hand

B

C

D

Protected against
access with finger

Protected against
access with tool

Protected against
access with wire

jets from any hosed
direction
Protected against water

6

splashes comparable to
heavy seas

7

Protected against total
immersion

Note:

P

(1) This is established by 2 tests:
• non penetration of a sphere with the diameter of 12.5 mm
• non accessibility of a test probe with a diameter of 12 mm.
(2) This additional letter only defines the access to dangerous components
Example: A device has an aperture allowing access with a finger. This will not be classified as IP 2x.However, if the components which are accessible with a finger are not dangerous (electric shock, burns, etc.), the device will be classified as xx B.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P51

IEC 947-1 & IEC 947-3 Standards
Selecting Switches According to IEC 947 -3 Standard
Utilization category

Use

Application

DC20

No-load making and breaking

Disconnector (device without on-load making and breaking capacity

AC21

DC21

Resistive including moderate overloads

AC22

DC22

AC23

DC23

AC

DC

AC20

Switches at installation head or for resistive circuits (heating, lighting, except discharge
lamps, etc.)

Inductive and resistive mixed loads including moderate

Switches in secondary circuits or reactive circuits (capacitor banks, discharge lamps, shunt

overloads

motors, etc.)

Loads made of motor or other highly inductive loads

Switches feeding one or several motors or inductive circuits (electric carriers, brake magnet,
series motor, etc.)

Breaking and Making Capacities

Electrical and Mechanical Endurance

Unlike circuit breakers, where these criteria indicate ­tr­ipping
or short-circuit making characteristics and perhaps requiring
device replacement, switch making and breaking ­capacities
corres­pond to utilization category maximum performance
values. In these uses, the switch must still maintain its
­characteristics, in particular its resistance to leakage current
and temperature rise.

This standard establishes the minimum number of electrical
(full load) and mechanical (no-load) operating cycles that must
be performed by devices. These characteristics also specify
the device’s theoretical lifespan during which it must maintain
its characteristics, particularly resistance to ­le­akage current
and temperature rise.­
This performance is linked to the device’s use and rating.
According to anticipated use, two additional application
categories are offered:
•• Category A: frequent operations (in close proximity to
the load),
•• Category B: infrequent operations (at installation head or
wiring system).

Making

Breaking

N° of operating

Ι/Ie

cos ϕ

Ι/Ie

cos ϕ

cycles

AC 21

1.5

0.95

1.5

0.95

5

AC 22

3

0.65

3

0.65

5

AC 23 I ≤ 100 A

10

0.45

8

0.45

5

AC 23 Ie > 100 A

10

0.35

8

0.35

3

L/R (ms)

L/R (ms)

DC 21

1.5

1

1.5

1

5

DC 22

4

2.5

4

2.5

5

DC 23

4

15

4

15

5

Ie (A)

≤ 100

≤ 315

≤ 630

≤ 2500

> 2500

N° cycles/hour

120

120

60

20

10

without current

8500

7000

4000

2500

1500

with current

1500

1000

1000

500

500

Total

10000

8000

5000

3000

2000

without current

1700

1400

800

500

300

with current

300

200

200

100

100

Total

2000

1600

1000

600

400

N° of operations in cat. A

N° of operations in cat. B

Making and breaking
capacities.

Short Circuit Characteristics
•• Short-time withstand current (Icw): allowable rms current
for 1 second.
•• Short circuit making capacity (Icm): peak current value
which the device can withstand when closed on a shortcircuit.
•• Conditional short circuit current: the rms current the
switch can withstand when associated with a protection
device limiting both the current and short circuit duration.
•• Dynamic withstand: peak current the device can
withstand in a closed position.
The characteristic established by this standard is the shorttime withstand current (Icw) from which minimal dynamic
withstand is deduced. This essential withstand value
corres­ponds to what the switch can stand without welding.

P52

Definitions
Conventional thermal current (Ith): Value of the current the
disconnect switch can withstand with pole in closed position,
in free air for an eight hour duty, without the temperature
rise of its various parts exceeding the limits specified by the
standards.
Rated insulation voltage (Ui): Voltage value which desi­
gnates the unit and to which dielectric tests, clearance and
creepage distances are referred.
Rated impulse withstand voltage (Uimp): Peak value of
an impulse voltage of prescribed form and polarity which the
equipment is capable of withstanding without failure under
specified conditions of test and to which the values of the
clearances are referred.
Rated operating current (Ie): Current value determined
by endurance tests (both mechanical and electrical) and by
making and breaking capacity tests.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Elevator Switch
Why do we offer our Fusible Shunt Trip Switch?
For a few different reasons:
•	

NFPA 13, 8.14.5

•	

NFPA 72 6.15.4.4

•	

ANSI/ASME A17.1

•	

NEC 620.91

We offer our fusible shunt trip switch as an all-in-one solution to meet the many
different code requirements with the protection and safety in elevator shafts.
According to NFPA 13, 8.14.5 sprinkler protection is required at the top and
bottom of elevator shafts. With that being said, NFPA 13 requires the installation
of sprinklers in the elevator machine room. Once a sprinkler system has been
introduced to either the elevator shaft or elevator machine room, you are now
installing these per the State-Adopted Elevator Code ANSI/ASME A17.1.
To summarize ASME A17.1, Safety Code for Elevators and Escalators, Rule 102.2 (c) (3), requires the shutdown of power to
the elevator prior to the application of water in the elevator machine room and or hoistway.
The shutdown of power is accomplished by a shunt trip device in the elevator circuit. This reduces the risk of any potential
electrical shock once the water is released into the system. This will also reduce the risk of any elevator car slippage once
the cables and hoist system become saturated from the release of water. In addition to turning off the power, 2002 NFPA 72
6.15.4.4 (Fire Alarm Code) requires:
“Control circuits to shut down elevator power shall be monitored for the presence of operating voltage. Loss of voltage to the
control circuit for the disconnecting means shall cause a supervisory signal to be indicated at the control unit and required
remote annunciation.”
This is achieved with our Fire Monitoring Relay, (FR Relay) that is standard in our Fusible Shunt Trip Device.
In the event of a power loss at which point a back up power supply is introduced to the system, you are now required to
meet NEC Article 620.91 paragraph (C) emergency or standby power system. This is accomplished with a set of mechanical
interlock auxiliary contacts which comes standard as 1-N/O and 1-N/C contact with our units. This prevents the elevator from
descending down and injuring any workers that could be working in the elevator shaft. This also allows the elevator to move to

P

the next convenient location and open the doors to let any passengers out in the event of an emergency.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P53

Selectivity Between

240, 480, or 600V Main and Branch Fuses
Definition

upstream fuse remains operable under all conditions of
overcurrent. The term “discrimination” is synonymous with
selectivity and is the preferred international term for
this definition.

Coordination (selectivity, discrimination) is desirable and
often times mandatory. A lack of coordination can represent
a hazard to people and equipment. When designing for
coordination, fuses provide distinct advantages over other
types of overcurrent protective devices.

The word all is key. Fuse selectivity cannot be assured by
comparing fuse time current curves alone. These curves stop
at .01 second. Fuse performance under high fault conditions
must also be evaluated. Fuse I2t is the best tool for assuring
coordination under high fault current conditions. If the total
clearing I2t of the downstream fuse is less than the melting I2t
of the main upstream fuse, the fuses will be selective under
high fault conditions.

Coordination is defined as properly localizing a fault
condition to restrict outages to the equipment affected,
accomplished by choice of selective fault protective devices.

To coordinate a circuit breaker protected system, it is
generally necessary to intentionally delay the short circuit
response of upstream breakers. Though coordination
may be achieved, short circuit protection is compromised.
The speed and consistency of response of fuses allows
coordination without compromising component protection.

To simplify presenting weighty I2t data, selectivity information
can simply be found in selectivity ratio tables.
The ratios found in the following tables are conservative and
are appropriate for all overcurrents up to 200,000 amperes
RMS. In some cases smaller ratios than shown may be
used. Consult your Mersen representative for specific
recommendations.

The terms coordination and selectivity are often used
interchangeably. The term coordination should be used to
describe a system as defined above, while two fuses are
said to be selective if the downstream fuse opens while the

Fuse Selectivity Ratios - 600 and 480 Volt Applications
Up to 200,000 RMS Symmetrical Amperes
Ratio (For Fuses Rated 61 – 600a)

Branch
Fuse
A4BQ

Main Fuse
A4BQ

A4BY

A4BT

TRS

A6K

A6D

A4J

AJT

A6T

2:1

2:1

2:1

-

-

-

-

-

-

A4BY

-

2.5:1

2:1

-

-

-

-

-

-

A4BT

2.5:1

2.5:1

2:1

-

-

-

-

-

-

TRS

4:1

4:1

3:1

2:1

4:1

4:1

4:1

3:1

4.5:1

A6K

2:1

2:1

1.5:1

1.5:1

2:1

2:1

3:1

2:1

3.5:1

A6D

2:1

2:1

1.5:1

1.5:1

2:1

2:1

3:1

2:1

3.5:1

A4J

2:1

2:1

1.5:1

1.5:1

2:1

2:1

2:1

2:1

3:1

AJT

2:1**

2:1**

2:1

1.5:1

2:1

2:1

2.5:1

2:1

3.5:1

A6T

3:1

2.5:1

2:1

1.5:1

2:1

2:1

2:1

2:1

2.5:1

Fuse Selectivity Ratios - 240 Volt Applications Up to 200,000 RMS Symmetrical Amperes
Ratio (For Fuses Rated 61 – 600a)
Main Fuse

Branch
Fuse
A4BQ

A4BQ

A4BY

A4BT

TR

A2K

A2D

A4J

AJT

A3T

2:1

2:1

2:1

-

-

-

-

-

-

A4BY

-

2.5:1

2:1

-

-

-

-

-

-

A4BT

2.5:1

2.5:1

2:1

-

-

-

-

-

-

TR

4:1

4:1

4:1

1.5:1

4:1

3:1

4:1

3:1

5:1

A2K

2:1

2:1

1.5:1

1.5:1

2:1

1.5:1

2:1

1.5:1

3:1

A2D

2.5:1

2.5:1

2:1

1.5:1

2:1

1:5:1

2:1

2:1

3:1

A4J

2:1

2:1

1.5:1

1.5:1

2:1

1.5:1

2:1

2:1

3:1

AJT

2:1

2:1

2:1

1.5:1

2.5:1

2:1

2.5:1

2:1

3:1

A3T

1.5:1

1.5:1

1.5:1

1.5:1

1.5:1

1.5:1

1.5:1

1.5:1

2:1

**Exception: For AJT450-600 use 2:1 on 480V only, 2.25:1 on 600V.

P54

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Short Circuit Calculations Quick Three Phase
Short circuit current levels must be known before fuses or
other equipment can be correctly applied. For fuses, unlike
circuit breakers, there are four levels of interest. These
are 10,000, 50,000, 100,000 and 200,000 RMS
symmetrical amperes.
Rigorous determination of short circuit currents requires
accurate reactance and resistance data for each power
component from the utility generating station down to the
point of the fault. It is time-consuming for a plant engineer
to collect all this information and yet he is the one most
affected by short circuit hazards.
There have been several approaches to “easy” short circuit
calculations which have been cumbersome to be of practical
use. The method described here is not new but it is the
simplest of all approaches.
Example 1:
What is the potential short circuit current at various points
in a 480V, 3-phase system fed by a 1000kVA, 5.75%Z
transformer? (Assume primary short circuit power to
be 500MVA.)
In summary, each basic component of the industrial
electrical distribution system is pre-assigned a single factor
based on the impedance it adds to the system. For instance,
a 1000kVA, 480 volt, 5.75%Z transformer has a factor of
4.80 obtained from Table A. This factor corresponds with
25,000 RMS short circuit amperes (directly read on Scale 1,
pg 55). Note: Factors change proportionally with transformer
impedance. If this transformer were 5.00%Z, the factor
would be 5.00/5.75 x 4.80 = 4.17.
Cable and bus factors are based on 100 foot lengths.
Shorter or longer lengths have proportionately smaller or
larger factors (i.e. 50’ length = 1/2 factor; 200’ length = 2
x factor). Basic component factors are listed on following
pages in tables A through D.

Answer:
From the Primary MVA correction factor table A1, the factor for
50MVA (at 480V) is 1.74. The new factor at the transformer is
then 4.80 + 1.74 = 6.54 and Isc is reduced to 18,000A (Scale
1). The new factor at the bus duct is 9.21 + 1.74 = 10.95 Isc =
11,000A (Scale 1).

P

To find the short circuit current at any point in the system,
simply add the factors as they appear in the system from
service entrance to fault point and read the available current
on Scale 1.

Example 2:
If the primary short circuit power were 50MVA (instead of
500MVA) in this same system, what would Isc be at the
transformer? At the end of the bus duct run?

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P55

Short Circuit Calculations Quick Three Phase
Component factor tables- transformers

A1- Transformer Correction Factors

The transformer factors are based on available primary
short circuit power of 500MVA and listed in Table A. For

Primary

systems with other than 500MVA primary short circuit

MVA

power, add the appropriate correction factors from Table A1

15

to the transformer factor found in Table A.

A- Three Phase Transformer Factors
Factor

Transformer

Factor
3 Phase Voltage

3 Phase Voltage

208

240

480

600

2.82

3.24

6.43

8.05

25

1.65

1.90

3.78

4.73

50

.78

.90

1.74

2.24

100

.34

.40

.80

1.00

150

.20

.23

.46

.58

250

.08

.10

.20

.25

Infinite

-.08

-.10

-.20

-.25

kVA

%Z

208

240

480

600

75

1.60

9.00

10.00

20.00

24.00

100

1.70

7.00

8.00

16.00

20.00

112.5

2.00

7.40

8.50

17.00

21.00

150

2.00

5.40

6.00

12.00

15.00

225

2.00

3.70

4.00

8.00

10.00

300

2.00

2.70

3.00

6.00

7.50

500

2.50

2.15

2.25

4.50

5.60

750

5.75

2.78

3.25

6.50

8.00

1000

5.75

2.24

2.40

4.80

6.00

transformer.

1500

5.75

1.48

1.60

3.20

4.00

Example:

2000

5.75

NA

1.20

2.40

3.00

For 208V, factor changes to (208 ÷ 480) x 3.00 = 1.30

2500

5.75

NA

.95

1.91

2.40

Notes: 208 volt 3φ transformer factors are calculated for 50%
motor load. 240, 480 and 600 volt 3φ transformer factors are
calculated for 100% motor load. A phase-to-phase fault is .866
times the calculated 3-phase value.

A2- Factor for Second Three Phase
Transformer in System
1. Determine system factor at the second transformer primary.
Example:
Isc @ 480V = 40,000A. Factor is 3.00 (from Scale 1).
2. Adjust factor in proportion to voltage ratio of second

3. Add factor for second 3φ transformer.
Example:
Factor for 100kVA, 208V, 1.70%Z transformer is 7.00.
	

Total Factor = 7.00 + 1.30 = 8.30

	

(Isc = 14,500A)

	
	
		

480V		
40,000A		

			

P56

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

208V
14,500A

100kVA

www.barr-thorp.com

Short Circuit Calculations Quick Three Phase
A3- Factors for Single Phase Transformer
in Three Phase System

A3- Single Phase Transformer Factors
Factor

Transformer connections must be known before factor can

1 Phase Voltage

Transformer

be determined. See Figures A and B (bottom right).

120V

240V

120V

kVA

%Z

FIG. A

FIG. A

FIG. B

1. Determine system factor at 1 transformer primary, with

15

2.5

34.6

48.0

24.0

480V pri., 120/240V sec. (Figure A)

25

2.5

20.7

28.8

14.4

Example:

37.5

2.8

16.6

23.0

11.5

50

3.0

12.5

17.3

8.65

75

3.0

8.28

11.5

5.75

100

3.0

6.22

8.64

4.32

150

2.5

3.46

4.80

2.40

167

2.5

3.10

4.31

2.16

225

2.5

2.30

3.20

1.60

300

3.0

2.07

2.88

1.44

500

4.5

1.86

2.59

1.30

Isc @480V = 40,000A, 3

Factor is 3.00 (from Scale 1).

		1 factor = 3 factor = 3.00 = 3.46
	
	
.866
.866
2. Adjust factor in proportion to voltage ratio of 480/240V
transformer.
Example:
For 240V, 1 factor is (240

480) 3.46 = 1.73

Note: Factor varies with %Z.
Example: 50kVA, 240V secondary with a 1.5%Z has a factor of
	
(1.5%Z ÷ 3.0%Z) x 17.3 = 8.65

3. Add factor for 1 transformer with Figure A connection.
Example:
Factor for 100kVA, 120/240V, 3%Z transformer is:
a. 120V--total factor = 6.22 + 1.73 = 7.95

		
	

(Isc = 15,000A)

b. 240V--total factor = 8.64 + 1.73 = 10.37

		

(Isc = 11,600A)

P

	

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P57

Short Circuit Calculations Quick Three Phase
Component Factor Tables - Cables in Duct
B/B1- Copper Cables in Duct (Per 100’)
B–Magnetic Duct

Cable
Size

B1–Non-Magnetic Duct

3 Phase Voltage

3 Phase Voltage

208

240

480

600

208

240

480

600

#8

79.00

68.00

34.00

27.00

78.00

67.60

33.80

27.10

6

50.00

43.00

22.00

17.50

47.90

41.50

20.70

16.60

4

32.00

28.00

14.00

11.15

30.70

26.70

13.30

10.70

2

21.00

18.00

9.00

7.23

19.90

17.20

8.61

6.89

1

17.50

15.00

7.40

5.91

16.20

14.00

7.07

5.60

1/0

14.00

12.20

6.10

4.85

13.20

11.40

5.70

4.57

2/0

11.80

10.20

5.10

4.05

10.60

9.21

4.60

3.68

3/0

9.80

8.50

4.27

3.43

8.87

7.59

3.85

3.08

4/0

8.40

7.30

3.67

2.94

7.57

6.55

3.28

2.62

250kcmil

7.70

6.70

3.37

2.70

6.86

5.95

2.97

2.38

300

7.00

6.10

3.04

2.44

5.75

4.98

2.49

1.98

350

6.60

5.70

2.85

2.28

5.36

4.64

2.32

1.86

400

6.20

5.40

2.70

2.16

5.09

4.41

2.20

1.75

500

5.80

5.00

2.49

2.00

4.66

4.04

2.02

1.62

600

5.50

4.80

2.40

1.91

4.29

3.72

1.86

1.49

750

5.20

4.50

2.26

1.80

4.05

3.51

1.76

1.41

C/C1- Aluminum Cables in Duct (Per 100’)
C–Magnetic Duct

Cable
Size

C1–Non-Magnetic Duct	

3 Phase Voltage
208

240

480

#8

129.00

112.00

56.00

6

83.00

72.00

4

53.00

2

35.00

1

3 Phase Voltage
600

208

240

45.00

129.75

112.45

56.20

480

45.00

600

36.00

29.00

80.00

69.10

34.60

27.70

46.00

23.00

18.50

51.10

44.20

22.10

17.70

30.00

15.00

12.00

33.00

25.70

14.30

11.40

28.00

24.00

12.00

9.50

26.30

22.80

11.40

9.12

1/0

21.50

18.50

9.70

7.70

21.20

18.40

9.20

7.36

2/0

18.50

16.00

8.00

6.40

17.00

14.70

7.34

5.87

3/0

15.00

13.00

6.50

5.20

13.80

12.00

6.02

4.79

4/0

12.50

11.00

5.50

4.40

11.50

9.95

4.98

3.99

250kcmil

11.10

9.60

4.80

3.85

10.10

8.72

4.36

3.49

300

9.90

8.60

4.30

3.42

8.13

7.04

3.52

2.81

350

8.60

7.40

3.70

3.00

7.49

6.50

3.07

2.45

400

8.30

7.20

3.60

2.90

6.87

5.95

2.98

2.38

500

7.40

6.40

3.20

2.60

6.12

5.31

2.66

2.13

600

7.20

6.20

3.10

2.44

5.30

4.59

2.29

1.83

750

6.50

5.60

2.80

2.22

4.85

4.20

2.10

1.69

Note: For parallel runs divide factor by number of conductors per phase.
Example: If factor for a single 500kcmil conductor is 2.49 then the factor for a run having 3-500kcmil per phase
is 2.49 ÷ 3 = .83 (Example from Table B, 480 volts)

P58

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Short Circuit Calculations Quick Three Phase
Component Factor Tables - Bus Duct

Isc = 120,000
Total Factor

D- Factors for Feeder* Bus Duct (Per 100’)

TOTAL FACTOR

3 Phase Voltage
Copper

Aluminum

.6

.7
.8
.9

Isc - RMS AMPERES
200,000

208

240

480

600

208

240

480

600

600

2.85

2.48

1.24

.99

2.54

2.19

1.10

.88

800

1.61

1.40

.70

.56

2.54

2.19

1.10

.88

1000

1.61

1.40

.70

.56

1.90

1.65

.82

.66

120,000
110,000
100,000

1200

1.21

1.06

.53

.42

1.60

1.36

.66

.54

90,000

1350

1.17

1.01

.51

.40

1.32

1.14

.57

.46

1600

1.03

.89

.45

.36

1.19

1.03

.52

.41

2000

.90

.78

.39

.31

.90

.77

.39

.31

2500

.63

.54

.27

.22

.70

.60

.30

.24

3000

.51

.44

.22

.18

.60

.52

.26

.21

4000

.37

.32

.16

.13

.43

.38

.19

.15

5000

.30

.26

.13

.10

--

--

--

--

* These factors may be used with feeder duct manufactured by I-T-E, GE, Square D and
Westinghouse.

1

1.5

80,000
75,000
70,000

65,000
2

60,000
55,000
50,000

2.5

D1- Factors for Plug-In** Bus Duct (Per 100’)

Copper

Aluminum

208

240

480

600

208

240

480

600

400

2.53

2.18

1.09

.89

3.88

3.34

1.67

1.36

600

2.53

2.18

1.09

.89

2.41

2.07

1.04

.84

800

1.87

1.61

.81

.66

2.41

2.07

1.04

.84

1000

1.87

1.61

.81

.66

1.69

1.45

.73

.59

1200

1.47

1.26

.63

.51

1.43

1.22

.61

.50

1350

1.26

1.08

.54

.44

1.30

1.12

.56

.45

1600

.91

.78

.39

.32

1.09

.94

.47

.38

2000

.79

.68

.34

.28

.89

.77

.38

.31

2500

.61

.52

.26

.21

.66

.57

.28

.23

3000

.48

.42

.21

.17

.59

.51

.25

.21

4000

.43

.37

.18

.15

.46

.40

.20

.16

5000

.38

.33

.16

40,000

3

3 Phase Voltage

Ampere
Rating

45,000

Factor

Duct

.13

.35

.30

150,000

.15

.12

** These factors may be used with plug-in duct manufactured by GE, Square D and
Westinghouse.

35,000
4

30,000
25,000

5
6
7
8
9
10
11

12

14
16
18
20
22

24

40
60
80
100

20,000
15,000

10,000
9,000
8,000
7,000
6,000
5,000
3,000
2,000

P

Ampere
Rating

Short Circuit Current

Factor

Duct

1,500
1,000

120

SCALE 1

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P59

Short Circuit Calculations Quick Three Phase
How Many Fuses Will Open On a Short Circuit?
In a three phase system typically only two fuses will open on a lineto-line short circuit. Since all three line currents are offset from each
other (see chart to the right), each fuse will see the full fault at different
times. Therefore the fuses will open at different times, once the first
two fuses open, the circuit is disconnected and the third one typically
never sees the full fault current. The third line can only conduct current
directly to ground.
How many fuses will open on an overload?
Similar to a short circuit typically two fuses will open on an overload.
Typically, one fuse opening will not be adequate to disconnect all three
phases so the two remaining phases will conduct the overcurrent
until one of them opens. At this point, the last fuse will only be able to
conduct current directly to ground so it most likely will not open.
Is it ok to replace only the open fuses?
It is always recommended to replace all three fuses. In both short
circuit and overload conditions the third fuse might not open but
there is no way to tell how much of the element may have melted
due to the overcurrent. Not replacing the third fuse can lead to
issues in the future such as nuisance openings which can result in
costly downtime.
Is there a life expectancy on my fuse?
A fuse does not have a “mean time between failures” because
theoretically a fuse only needs to be replaced once it opens on
an overcurrent. Fuses are 100% tested before leaving the factory
to ensure that they will perform as intended. In the real world,

Fuses are 100%
tested before
leaving the
factory to ensure
they will perform
as intended.

factors such as temperature and humidity can cause a fuse to need
replacement. Mersen suggests using ten years as a guideline for
replacing both fuses installed and in inventory.

P60

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Properties of Materials*
Fuse Blocks, Fuse Holders, Power Distribution Blocks, Fuses & Accessories
Property
Specific Gravity

Units
-

Astm
Test
D792

Phenolic

Glass Filled
Polycarbonate

1.4

1.21

Polyamide
1.36

Polyethelene

Polysulfone

Terphthalate

Copolymer

1.67

1.52

Polyphtalamide

Nylon

1.71

1.16
0.63

IZOD

ft-lb/in

D256

0.29

4-6

3.2

1.7

1.8

1.5

Flexural Strength

psi

D790

11,000

13,200

38,000

29,000

26,900

37,300

18,500

Flexural Modulus

psi

D790

1.1 x 106

325,000

1.25 x 106

1.5 x 106

1.4 x 106

1.9 x 106

4.3 x 105

Tensile Strength

psi

D638

7,000

9,000

25,000

20,000

17,600

26,000

12,000

Compressive Strength

psi

D695

28,800

12,500

34,000

29,000

-

-

-

Water Absorption

24 hrs %

D570

0.45

0.15

1.3

0.05

0.1

0.18

1.5

Hardness

Rockwell

D785

M-110

M-85

R-105

R-120

-

-

-

Dielectric Strength
60 hertz, 25ºC, s/t

vpm

-

300

425

435

460

500

460

432

60 hertz, 25ºC, s/s

vpm

-

250

425

-

355

-

-

-

Dielectric Constant
60 hertz–dry

-

D150

5.96

3.01

-

3.8

-

-

1 Mhertz–dry

-

D150

4.9

2.96

3.6

3.7

3.8

4.9

3.6

Volume Resistivity

ohm-cm

D257

50 x 106

>1016

1016

>1015

>1016

3 x 1016

>1016

Heat Deflection

ºF

D648

320

270

410

435

330

523

167

-

-

94 V-0

94 V-0

94 V-0

94 V-0

94 V-0

94 V-0

94 V-0

ºC

-

150

125

150

155

150

140

140

ºC

-

150

125

140

155

150

130

110

AOS

FSPDB

(ºF @ 264 psi)
Flammability
(UL 94)
Relative Thermal Index
(RTI)
(UL746B)
Mechanical without
impact

*Note: Above data represents
approximate values and are for
reference only.

Product Types & Families
61XXXX

PDB

USM

GPM

62XXXX

DRM

USCC

FEB

SHR

64XXXX

DFC

US3J

FEX

22XXXX

603XXX

US6J

IL

24XXXX

203XXX

US14

TPMOV

26XX

206XXX

US22

Surge Trap

P266

303XXX

CC

1SC

P243

306XXX

MSC

1MSC

P243X

NH

PS2OX127

703XX

FHXXX

U705XX

EI

U710XX
21XXXX
61XXXSJ

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

P

Electrical

www.barr-thorp.com

P61

Application Information
Comparative Data of
Stranded Copper and
Aluminum Cables
Size

P62

Area

Recommended
Tightening Torque
for Bolt-On and Stud
Mounted Fuses

Awg

Circular

Square

Kcmil

Mils

Millimeters

30

100.5

0.051

28

159.8

0.081

26

254.1

0.123

24

404.0

0.205

22

642.4

0.326

20

1022

0.518

18

1620

0.823

16

2580

1.31

14

4110

2.08

12

6530

3.31

10

10380

5.26

8

16510

8.37

6

26240

13.3

4

41740

21.2

Thread

3

52620

26.7

Size

2

66360

33.6

1

83690

42.4

1/0

105600

53.5

2/0

133100

67.4

3/0

167800

85.0

4/0

211600

107

250

-

300

English Sizes
Tightening Torque

Thread
Size

ft-lbs

in-lbs

1/4-20

4

50

5/16-18

7.5

90

3/8-16

13

160

3/8-24

15

180

1/2-13

30

360

1/2-20

31

375

Metric Sizes
Tightening Torque

Small Ampere Rating
Equivalents
Fraction

Decimal

Milliamps

1/100

0.0100

10

1/64

0.0156

15

1/32

0.03125

32

4/100

0.0400

40

5/100(1/20)

0.0500

50

1/16

0.0625

63

8/100

0.0800

80

1/10

0.10

100

1/8

0.1250

125

15/100

0.150

150

16/100

0.160

160

175/1000

0.1750

175

3/16

0.1875

188

2/10

0.20000

200

1/4

0.2500

250

3/10

0.3000

300

315/1000

0.3150

315

3/8

0.3750

375

4/10

0.4000

400

1/2

0.5000

500

6/10

0.6000

600

630/1000

0.6300

630

7/10

0.7000

700

127

3/4

0.7500

750

-

152

8/10

0.8000

800

350

-

177

9/10

0.9000

900

400

-

203

1

1.000

1000

500

-

253

600

-

304

700

-

355

750

-

380

800

-

405

900

-

456

1000

-

507

1250

-

634

1500

-

760

1750

-

887

2000

-

1014

newton-meters

in-lbs

M6

6

53

M8

13

115

M10

26

230

M12

45

398

M16

84

740

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Application Information
Short Circuit Rating (SCCR)

The National Electric Code (2008) defines Short-Circuit
Current Rating (article 100) as “the prospective symmetrical
fault current at a normal voltage to which an apparatus or
system is able to be connected without sustaining damage
exceeding defined acceptance criteria.” SCCR is important
to provide for safety of people and equipment during shortcircuit conditions.
Article 409.110 (3) states that industrial control panels shall
be marked with “short-circuit current rating of the industrial
control panel based on one of the following: (a) shortcircuit current rating of a listed and labeled assembly (b)
short-circuit current rating established utilizing an approved
method.” The fine print note refers to UL 508A, supplement
SB as an example of an approved method. 430.8 require
motor controllers to be marked with an SCCR.

Long Life

The speed of response of a fuse will not change or slow 	
down as the fuse ages. In other words, the fuse’s ability to
provide protection is not adversely affected by the passage
of time.

Minimal Maintenance

Fuses do not require periodic recalibration as do
electromechanical overcurrent protective devices.

Component Protection

The current limiting action of a fuse minimizes or eliminates
component damage.

North American Standards

Tri-national Standards specify fuse performance and
maximum allowable fuse Ip and I2t let-thru values.

Supplement SB in UL 508A uses a four step process to
determine what a short circuit current rating for a panel
should be. This process identifies the components with the
lowest individual SCCR in the circuit. If there is no feeder
over-current protective device (OCPD) this component is the
weakest link and would determine the overall SCCR of the
panel. Typically the feeder circuit will have an OCPD and we
must consider its current-limiting effects on the circuit.

Selectivity

The feeder OCPD may limit fault currents enough so that the
weakest link components are protected and the panel can
have a higher overall SCCR. For more information please
contact Mersen Technical Services at 978-462-6662 or
technicalservices.nby@mersen.com.

Cost Effective

Fuses may be easily coordinated to provide selectivity under
both overload and short circuit conditions.

High Interrupting Rating

You don’t pay a premium for high interrupting capacity.
Most low voltage current limiting fuses have a 200,000
ampere interrupting rating.
Fuses are generally the most cost effective means of
providing overcurrent protection. This is especially true
where high fault currents exist or where small components
need protection.

Extended Protection
11 Reasons For Using
Current-Limiting Fuses:
Arc Flash Reduction

Devices with low interrupting ratings are often rendered
obsolete by service upgrades or increases in available fault
current. Non-fused systems may need expensive system
upgrades to maintain system safety.

Current limiting fuses, when applied within their current
limiting range, reduce personnel exposure to incident
arc flash energy. Non fused systems may need extensive
re-engineering to reduce arc flash hazards, and improve
personnel safety.

Safety

P

Overcurrent protective devices which operate are often reset 	
without first investigating to find the cause of opening.
Electromechanical devices which have opened high level
faults may not have the reserve capacity to open a 2nd or
3rd fault safely. When a fuse opens it is replaced with a new
fuse, thus protection is not degraded by previous faults.

Reliability

No moving parts to wear or become contaminated by dust,
oil or corrosion.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P63

Application Information
Three Clues for Detecting When is a Fuse Too Old for Storeroom Inventory?
Storeroom managers often have the responsibility for identifying obsolete inventory. There are advantages to having the right
inventory for needs, without the clutter of fuses that should never be used. Obsolete fuses can mask stock-out of important
spare fuses resulting in needless emergencies. Sometimes, an electrician will mistakenly use an obsolete fuse and create a
dangerous safety condition.
What conditions would make a fuse obsolete? There is functional obsolescence, concealed damage obsolescence, and age
obsolescence. Any of these conditions justify discarding a fuse. The electrical safety experts at Mersen offer the following
three clues for determining when a fuse should be removed from storeroom inventory:
1. Functional Obsolescence
Functional obsolescence occurs when the fuse can’t protect the equipment due to changes in the electrical system, or when
the end-use equipment needing this particular fuse has been abandoned. Either way, the fuse will not help in restoring the
equipment to service. If it’s accidently used by an electrician, it could create a hazardous situation.
An example of a functionally obsolete fuse is a One-Time with a safety rating of only 10kA IR. When the fuse was originally
purchased, it could have had an adequate safety rating. Now the electrical system has changed and requires a safety rating of
more than 10kA. If the fuse is installed without adequate IR as required by OSHA, it could explode or cause personal injury.
2. Concealed Damage
Obsolescence can be caused by concealed damaged. An electrician normally only checks for fuse continuity to determine its
suitability for continued service. But other concealed damage can occur in storage. The biggest threat to fuses in storage is
moisture.
Once fuses absorb too much moisture, they lose their interrupting (safety) capacity. Even if they are dried out after the
exposure, they are permanently damaged. In normal use they generate enough heat to keep themselves safe from absorbing
moisture, but not in storage. The absorption of moisture permanently changes the structure of the filler packing around the
fuse link and consequently decreases the safety capacity.
A common check for water damage is to check for wrinkling on the fuse’s paper label. If the paper label is wrinkled, it indicates
excessive moisture during storage. Also, any water stains on the fuse body or corrosion on the ends can indicate moisture
damage.
Other concealed damage can occur when a fuse is used and returned to the storeroom. Any fuse that show scratches on the
blades or ferrules was probably inserted into fuse clips and returned to inventory.
3. Fuses Over 10 Years Old
When fuses are more than 10 years old, the history of these fuses is uncertain. More than likely, they were exposed to
moisture or damaging conditions sometime during the 10 years of storage. This would make them unsafe and unreliable for
maintenance. Most manufacturers mark a date code on their fuses.
Summary
If storeroom fuses exhibit functional obsolescence, signs of moisture damage, or are more than 10 years old, they should be
replaced. For a free fuse audit and inventory analysis, visit call 978-462-6662.

P64

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Application Information
Class 1 Division 2 Locations
List of Mersen products that meet the description of “non-indicating, filled, current-limiting” as referenced in Section 501.115(B)
(3) of the 2008 National Electrical Code, allowing them to be used in standard enclosures.
Cat. No.

U.L. Class

U.L. Standard

Guide

File

A2D(1/10- 7)R*

RK1

248-12

JDDZ

E2137

A2K(1- 600)R

RK1

248-12

JDDZ

E2137

A3T(1- 1200)

T

248-15

JDDZ

E2137

A4BT(601- 6000)*

L

248-10

JDDZ

E2137

A4BQ(601- 6000)*

L

248-10

JDDZ

E2137

A4BY(601- 6000)

L

248-10

JDDZ

E2137

A4J(1- 600)

J

248-8

JDDZ

E2137

A6D(1/10- 7)R*

RK1

248-12

JDDZ

E2137

A6K(1- 600)R

RK1

248-12

JDDZ

E2137

A6T(1- 800)

T

248-15

JDDZ

E2137

AG(3- 60)*

G

248-5

JDDZ

E2137

AJT(1- 7)*

J

248-8

JDDZ

E2137

ATDR(1/4- 30)*

CC

248-4

JDDZ

E2137

ATMR(2-1/2 - 30)

CC

248-4

JDDZ

E2137

ATQR(2- 30)*

CC

248-4

JDDZ

E2137

HSJ(1- 600)

J

248-8

JDDZ

E2137

HSRK(70- 600)R

RK1

248-12

JDDZ

E2137

TR(1/10- 600)R* +

RK5

248-12

JDDZ

E2137

TRS(1/10- 600)R* +

RK5

248-12

JDDZ

E2137

*A Time Delay Fuse
+ Blue Label Fuses Only

Since all of the above fuses meet the “non-indicating, filled, current-limiting” specifications, they are suitable for use in

P

standard enclosures for Class 1 Division 2 applications.

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P65

Application Information
Suggested Fuse Specifications
1.0 General
The electrical contractor shall furnish and install a complete
set of fuses for all fusible equipment on the job as specified
by the electrical drawings. Final tests and inspections
shall be made prior to energizing the equipment. This shall
include tightening all electrical connections and inspecting
all ground conductors. Fuses shall be as follows:
2.0 Mains, Feeders and Branch Circuits
A. Circuits 601 to 6000 amperes shall be protected by
current-limiting Mersen Amp-Trap 2000® Class L time-delay
A4BQ fuses. Fuses shall be time-delay and shall hold
500% of rated current for a minimum of 4 seconds, clear 20
times rated current in .01 second or less and be UL Listed
and CSA Certified with an interrupting rating of 200,000
amperes rms symmetrical.
B. Circuits 600 amperes or less shall be protected by
current-limiting Mersen Amp-Trap 2000® Class RK1 timedelay A2D (250V) or A6D (600V) or Class J time-delay
AJT fuses. Fuses shall hold 500% of rated current for a
minimum of 10 seconds (30A, 250V Class RK1 case size
shall be a minimum of 8 seconds) and shall be UL Listed
and CSA Certified with an interrupting rating of 200,000
amperes rms symmetrical.
C. Motor Protection
All individual motor circuits shall be protected by Mersen
Amp-Trap 2000® Class RK1, Class J or Class L time-delay
fuses as follows:
Circuits up to 480A:	
			
			

Class RK1 - A2D (250V) or 	
A6D(600V)
Class J - AJT

Circuits over 480A:	

Class L - A4BQ

E. Circuit breakers and circuit breaker panels shall be
protected by Mersen Amp-Trap 2000® fuses Class RK1
(A2D or A6D), Class J (AJT) or Class L (A4BQ) chosen in
accordance with tested UL Series-connected combinations
published in the current yellow UL Recognized
Component Director.
F. Supplementary lighting and control circuits in the
connected combinations shown up to 600VAC and 24 amps
shall be protected by Mersen Amp-Trap 2000® Class CC
time-delay ATQR or ATDR fuses, sized according to the
fixture manufacturers recommendations.
3.0 Spares
Spare fuses amounting to 10% (minimum three) of each
type and rating shall be supplied by the electrical contractor.
These shall be turned over to the owner upon project
completion. Fuses shall be contained and cataloged within
the appropriate number of spare fuse cabinets (no less than
one). Spare fuse cabinets shall be equipped with a key lock
handle, be dedicated for storage of spare fuses and shall
be GSFC, as supplied by Mersen.
4.0 Execution
A. Fuses shall not be installed until equipment is to be
energized. All fuses shall be of the same manufacturer
to assure selective coordination.
B. As-installed drawings shall be submitted to the engineer
after completion of the job.
C. All fusible equipment rated 600 amperes or less shall
be equipped with fuse clips to accept Class RK1 or Class J
fuses as noted in the specifications.
5.0 Substitution
Fuse sizes and types indicated on drawings are based on
Mersen Amp-Trap 2000® fuse current-limiting performance
and selectivity ratios. Alternative submittals to furnish
materials other than those specified, shall be submitted to
the engineer in writing two weeks prior to bid date, along
with a short circuit and selective coordination study.

Fuse sizes for motor protection shall be chosen from tables
published by Mersen for the appropriate motor rating.
Heavy load and maximum fuse ratings are also shown for
applications where typical ratings are not sufficient for the
starting current of the motor.
D. Motor Controllers
Motor controllers shall be protected from short circuits
by Mersen Amp-Trap 2000® time-delay fuses. For Type 2
protection of motor controllers, fuses shall be chosen in
accordance with motor control manufacturers’ published
recommendations, based on Type 2 test results. The fuses
shall be Class RK1 A2D (250V) or A6D (600V) or Class J
AJT or Class CC ATDR (600V).

P66

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P

Application Notes

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

P67

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Advisor
Part Number		

Description		

INDEX

Page

Index

Part Number		

Description		

Page

08530

Power Distribution Block Covers

I5

2A391

NH Dimension Knife-Blade Fuse-Links, aM

F19

08570

Power Distribution Block Covers

I7

2B389

NH Dimension Knife-Blade Fuse-Links, aM

F19

08590

Power Distribution Block Covers

I9

2C163 - 2C175

NH Dimension Knife-Blade Fuse-Links, aM

F19

1021 CP URB 27x60

Semicond. French. Cyl. Fuse, 690V - 1000V

D68

2C245 - 2C375

NH Dimension Knife-Blade Fuse-Links, aM

F19

11 URD

PSC Semicond. Fuse 1250/1300V

D55

2C377 - 2CC387

NH Dimension Knife-Blade Fuse-Links, aM

F19

12,5URD

PSC Semicond. Fuse 1250/1300V

D55

2C023 - 2C069

NH Dimension Knife-Blade Fuse-Links, aM

F18

NH Dimension Knife-Blade Fuse-Links, aM

F18

12 URD

PSC Semicond. Fuse 1250/1300V

D55

2C135 - 2C159

132, 162, 166

Fuse Reducers, Class H&K

J3

2C613 - 2C765

NH Dimension Knife-Blade Fuse-Links, aM

F18

F3

2CL

Special Purpose Cable Protectors, 250V

G10

300V Class T Fuse Blocks

H26

15009-G - 18065-G

French Ferrule Fuse, gl-gG

15511-G - 18565-G

French Ferrule Fuse, aM

F5

30305T - 30659T

1652., 1653.

Diazed D Gauge Rings

F13

30310 - 30354

600V Midget and Class CC Fuse Blocks

H17

1655.

Diazed D Gauge Pieces

F13

30310R-30354R

600V Midget and Class CC Fuse Blocks

H17

F13

31001T - 36051T

300V Class T Fuse Blocks

H27

Neozed DO Fuse Links

F7

32-001G - 34-016G

Fuse Pullers, Clip Clamps

J4

1705., 1706., 1701.

Neozed DO Gauge Rings

F8

40002-G - 45214-G

Bases, Shields, etc., for NH Fuse Links

H50

1707-L

Neozed DO Accessories (Spacer)

F10

40110G - 40658G

Fuse Blocks for Class G Fuses

H31

F10

41002-G - 42119-G

Fuse Bases for NH Fuse Links

H52

Fuse Bases for NH Fuse Links

H53

1657., 1658.
1700., 1701., 1702.

1708-L

Diazed D Screw Gauge Pieces

Neozed DO Accessories (Gauge Ring Key)

1709-L, 1713-L

Neozed DO Accessories (Special Holding Spring)

F10

41202-G - 42619-G

1710., 1711., 1712.

Neozed DO Screw Caps (Porcelain)

F8

44502-G - 45437-G

Bases, Shields, etc., for NH Fuse Links

H54

F8

412, 422

Fuse Reducers, Class H&K

J3

45DB

IEC Back-Up Fuse Links

E50

1714., 11714., 11715.,
1715-

Neozed DO Screw Caps (Plastic)

1716.333-L, 1716-L

Neozed DO Accessories (Screw Cap Remover)

F10

5,5 URD

PSC Semicond. Fuse 690/700V

D44

1718., 1721.03-L,
1728., 1732.

Neozed DO Insulating Covers

F8

581-L

Diazed D Adapter Fittings

F14

1720., 1721., 1722.,
1730., 1731

Neozed DO Fuse Bases

F9

589-, 592-, 690-,
691- (-L)

Diazed D Screw Caps

F13

17413-G - 18465-G

Cylindrical Fuse-Links, gl-gG

F4

594., 595., 596., 597.,
598.,

Diazed D Fuse Link 500VAC

F12

17911-G - 18965-G

Cylindrical Fuse-Links, aM

F6

5 URB 000 BS88

Protistor Semicond. BS88 Fuse, 500-660V

D31

181.9-L, 182.9-L

Diazed D Touch Protection Rings

F14

5URB 000

Protistor Semicond. Fuse, 690V

D28

1B173 - 1B175

NH Dimension Knife-Blade Fuse-Links, gL, gG, 690V

F16

5X20QC1

Fuse Blocks for 5mmx20mm Fuses

H32

1C023 - 1C069

NH Dimension Knife-Blade Fuse-Links, gL, gG, 690V

F16

60300 - 60658

600V Class H, K, and R Fuse Blocks

H22

1C135 - 1C171

NH Dimension Knife-Blade Fuse-Links, gL, gG, 690V

F16

60305R - 60658R

600V Class H, K, and R Fuse Blocks

H22

1C243 - 1C281

NH Dimension Knife-Blade Fuse-Links, gL, gG, 690V

F17

60300J - 60658J

600V Class J Fuse Blocks

H13

1C375 - 1C387

NH Dimension Knife-Blade Fuse-Links, gL, gG, 690V

F17

60305T - 60658T

600V Class T Fuse Blocks

H28

1C613 - 1C659

NH Dimension Knife-Blade Fuse-Links, gL, gG, 690V

F16

61005SJ - 61008J

600V Class J Fuse Blocks

H14

1C743 - 1C765

NH Dimension Knife-Blade Fuse-Links, gL, gG, 690V

F16

61031T - 66051T

600V Class T Fuse Blocks

H29

1SC, 1MSC

Semiconductor Fuse Blocks

H45

61035 - 62053

600V Class H, K, and R Fuse Blocks

H23

20300 - 20658

250V Class H, K, and R Fuse Blocks

H19

61035R - 62053R

600V Class H, K, and R Fuse Blocks

H23

20305R - 20658R

250V Class H, K, and R Fuse Blocks

H19

62001J - 6663J

600V Class J Fuse Blocks

H15

2071.8., 2072.8- (-L)

Diazed D Locking Caps

F14

64001 - 6663

600V Class H, K, and R Fuse Blocks

H24

21035 - 22053

250V Class H, K, and R Fuse Blocks

H20

6,6 URD

PSC Semicond. Fuse 690/700V

D44

212, 262, 266

Fuse Reducers, Class H&K

J3

685., 686.

Diazed D Fuse Link

F11

21035R - 22053R

250V Class H, K, and R Fuse Blocks

H20

6,9 URE 10

Protistor Semicond. British Stnd. Fuse, 690V

D39

228-700-520

Fuse Clips, Medium Voltage

E17

6,9 URS 17

Protistor Semicond. British Stnd. Fuse, 690V

D39

24001 - 2663

250V Class H, K, and R Fuse Blocks

H21

6,9 URT 217

Protistor Semicond. British Stnd. Fuse, 690V

D39

24001R - 2663R

250V Class H, K, and R Fuse Blocks

H21

690., 691.

Diazed D Screw Caps

F13

2.5 URE 10

Protistor Semicond. British Stnd. Fuse, 250V

D35

6.900 CP URC 14x51

Protistor Semicond. French. Cyl. Fuse, 690V

D65

2.5 URGG 36

Protistor Semicond. British Stnd. Fuse, 250V

D37

6.900 CP URD 22x58

Protistor Semicond. French. Cyl. Fuse, 690V

D65

2.5 URGH 236

Protistor Semicond. British Stnd. Fuse, 250V

D37

6.921 CP URC 14x51

Protistor Semicond. French. Cyl. Fuse, 690V

D65

2.5 URGS 17

Protistor Semicond. British Stnd. Fuse, 250V

D35

6.921 CP URD 14x51

Protistor Semicond. French. Cyl. Fuse, 690V

D65

2.5 URZ 17

Protistor Semicond. British Stnd. Fuse, 250V

D35

6.921 CP URD 22x58

Protistor Semicond. French. Cyl. Fuse, 690V

D65

2631-2663R

250V Class H, K, and R Fuse Blocks

H21

6,921 CP URGD 27x60

Protistor Semicond. French. Cyl. Fuse, 600V - 690V

D67

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

INDEX 1

Advisor
Part Number		

Description		

INDEX

Page

Index

Part Number		

Description		

Page

6,921 CP URQ 27x60

Semicond. French. Cyl. Fuse, 690V - 1000V

D68

9F60FJB

2.75kV E-Rated Power Distribution Fuse

E4

6,9gRB 000

Semicond. Fuse, German Stnd. 500V - 690V

D28

9F60FJD

5.5kV E-Rated Power Distribution Fuse

E6

6,9URB 000

Semicond. Fuse, German Stnd. 500V - 690V

D28

9F60FJE

8.25kV E-Rated Power Distribution Fuse

E7

6,9 URD

PSC Semicond. Fuse 690/700V

D44

9F60FMH

15.5kV E-Rated Power Distribution Fuse

E8

6,9 URD 00

Protistor Semicond. Fuse, 690V

D33

9F60FNJ

25.8kV E-Rated Power Distribution Fuse

E10

6,9gRB 00

Protistor Semicond. Fuse, 690V

D33

9F60FPK

38kV E-Rated Power Distribution Fuse

E11

6,9gRB 000

Protistor Semicond. Fuse, 690V

D28

9F60FPT

38kV E-Rated Power Distribution Fuse

E11

6,9gRB 000 BS88

Protistor Semicond. BS88 Fuse, 500-690V

D31

9F60GCB

2.75kV E-Rated Power Distribution Fuse

E4

6,9gRB 17x49

Protistor Semicond. Fuse, 690V

D26

9F60HJB

2.75kV E-Rated Power Distribution Fuse

E4

6,9URB 00

Protistor Semicond. Fuse, 690V

D33

9F60HJD

5.5kV E-Rated Power Distribution Fuse

E6

6,9URB 000

Protistor Semicond. Fuse, 690V

D28

9F60HJE

8.25kV E-Rated Power Distribution Fuse

E7

6,9URB 17x49

Protistor Semicond. Fuse, 690V

D26

9F60HMH

15.5kV E-Rated Power Distribution Fuse

E8

6,9 URGL 36

Protistor Semicond. British Stnd. Fuse, 690V

D41

9F60HNJ

25.8kV E-Rated Power Distribution Fuse

E10

6,9 URGM 236

Protistor Semicond. British Stnd. Fuse, 690V

D41

9F60HPK

38kV E-Rated Power Distribution Fuse

E11

6,9 URR 36

Protistor Semicond. British Stnd. Fuse, 690V

D41

9F60HPT

38kV E-Rated Power Distribution Fuse

E11

6,9 URU 236

Protistor Semicond. British Stnd. Fuse, 690V

D41

9F60KLH

15.0kV E-Rated Power Distribution Fuse

E8

64001R - 6663R

600V Class H, K, and R Fuse Blocks

H24

9F60LCB

2.4kV R-Rated EJ-2 Series

E23

60305SJ-60358SJ

Fuse Blocks for Class SJ Fuse

H13

9F60LCL

2.4kV R-Rated EJ-2 Series

E23

612, 622, 632, 636, 642

Fuse Reducers, Class H&K

J3

9F60LJD

5.08kV R-Rated EJ-2 Series

E25

62000 - 63000

Power Distribution Blocks - Mini 62000 and 63000 Series

I5

9F60LJN

5.08kV R-Rated EJ-2 Series

E25

66000 - 67000

Power Distribution Blocks Intermediate 66000 - 67000
Series

I6

9F60MCB

2.4kV R-Rated EJ-2 Series

E23

9F60MCL

2.4kV R-Rated EJ-2 Series

E23

68000 - 69000

Power Distribution Blocks 68000 - 69000 Large Series

I8

9F60MJD

5.08kV R-Rated EJ-2 Series

E25

6URD

PSC Semiconductor Fuse 690/700V

D44

9J60MJN

5.08kV R-Rated EJ-2 Series

E25

6X32QC1

Fuse Blocks for 1/4”x1-1/4” Fuses

H32

9F60NLD

5.08kV R-Rated EJ-2 Series

E25

703, U705, U710

Semiconductor Fuse Blocks - “Open-Block”

H46

9F60RJD

5.5kV 9F60 Series Capacitor Fuse

E43

8004., 8014

NH Dimension Knife-Blade Fuse-Links, gL, gG, 690V

F17

9F60RJF

9.52kV 9F60 Series Capacitor Fuse

E43

81., 72.

Diazed D Fuse Link

F11

9F61

E53

821 CP GRB 27x60

Semicond. French. Cyl. Fuse, 800V

D70

Type EK 9F61 Series Fuse Supports, Disconnect Switches,
Accessories

9F59UBC

8.3kV Sure Guard ETP Fuse

E45

9F62DCB

5.5kV E-Rated General Purpose Fuse

E6

9F59UBD

15.5kV Sure Guard ETP Fuse

E46

9F62DCC

8.3kV General Purpose Fuse

E7

9F59UBE

23.0kV Sure Guard ETP Fuse

E47

9F62DDD

15.5kV General Purpose Fuse

E9

9F60AAA

.625kV 9F60 Series Potential Transformer Fuse

E33

9F62FCB

5.5kV E-Rated General Purpose Fuse

E6

9F60AAB

2.75kV 9F60 Series Potential Transformer Fuse

E33

9F62FCC

8.3kV General Purpose Fuse

E7

9F60BBB

2.75kV 9F60 Series Potential Transformer Fuse

E33

9F62FDD

15.5kV General Purpose Fuse

E9

9F60BBD

5.5kV 9F60 Series Potential Transformer Fuse

E34

9F62HCB

5.5kV E-Rated General Purpose Fuse

E6

9F60BBN

5.5kV 9F60 Series Potential Transformer Fuse

E34

9F62HCC

8.3kV General Purpose Fuse

E7

9F60BDB

2.75kV 9F60 Series Potential Transformer Fuse

E33

9F62HDD

15.5kV General Purpose Fuse

E9

9F60BDD

5.5kV 9F60 Series Potential Transformer Fuse

E34

9F62KCB

5.5kV General Purpose Fuse

E14

9F60BDE

8.25kV 9F60 Series Potential Transformer Fuse

E35

9F62KED

15.5kV General Purpose Fuse

E15

9F60BHH

15.5kV 9F60 Series Potential Transformer Fuse

E35

A033D1

3.3kV R-Rated Medium Voltage DIN Style

E31

9F60CCB

2.75kV E-Rated Power Distribution Fuse

E4

A050 URB T13

Protistor Semicond. French. Cyl. Fuse, 10x38, 500/600V

D63

9F60CEB

2.75kV E-Rated Power Distribution Fuse

E4

A050 URD T13

Protistor Semicond. French. Cyl. Fuse, 10x38, 500/600V

D63

9F60CED

5.5kV E-Rated Power Distribution Fuse

E5

A050 URL T13

Protistor Semicond. French. Cyl. Fuse, 10x38, 500/600V

D63

9F60CJH

15.5kV E-Rated Power Distribution Fuse

E8

A050B

5.0kV Bolt-In Medium Voltage Fuse

E13

9F60CMJ

25.8kV E-Rated Power Distribution Fuse

E10

A050URD

PSC Semicond. Fuse 690/700V

D44

9F60DJB

2.75kV E-Rated Power Distribution Fuse

E4

A051B

5.08kV R-Rated Bolt-in Medium Voltage Fuse

E28

9F60DJD

5.5kV E-Rated Power Distribution Fuse

E6

A055B

5.5kV E-Rated Bolt-In Medium Voltage Fuse

E13

9F60DJE

8.25kV E-Rated Power Distribution Fuse

E7

A055C

5.5kV E-Rated CL-14 Medium Voltage Fuse

E18

9F60DMH

15.5kV E-Rated Power Distribution Fuse

E8

A055D1

5.5kV R-Rated Medium Voltage DIN Style

E31

9F60DNJ

25.8kV E-Rated Power Distribution Fuse

E10

A055F

5.5kV E-Rated CS-3 Medium Voltage Fuse

E5

9F60ECB

2.75kV E-Rated Power Distribution Fuse

E4

A055URD

PSC Semicond. Fuse 690/700V

D44

INDEX 2

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Advisor
Part Number		

Description		

INDEX

Page

Index

Part Number		

Description		

Page

A060 URD T13

Protistor Semicond. French. Cyl. Fuse, 10x38, 500/600V

D63

A70QS-14F

Amp-Trap Semicond. French. Cyl. Fuse, 700V

D14

A060URD

PSC Semicond. Fuse 690/700V

D44

A70QS-22F

Amp-Trap Semicond. French. Cyl. Fuse, 700V

D14

A065URD

PSC Semicond. Fuse 690/700V

D44

A70QS-4

Amp-Trap Form 101 Semicond. Fuse, 700V

D16

A070gRB

Protistor Semicond. Fuse, 550V

D13

A720T

7.2kV Potential Transformer Fuse

E35

A070URD

PSC Semicond. Fuse 690/700V

D44

A825X

8.25kV E-Rated CS-3 Medium Voltage Fuse

E7

A072B

7.2kV E-Rated Bolt-In Medium Voltage Fuse

E15

AC3, AC4, AC5, AC6

K19

A072B

7.2kV R-Rated Bolt-In Medium Voltage Fuse

E29

Aux.Contact Block Holder for FB Series Fusible Disconnect
Switches 30 to 60A

A072D1

7.2kV R-Rated Medium Voltage DIN Style

E31

AC3, AC4, AC5, AC6

K20

A072F

7.2kV R-Rated Medium Voltage Fuse

E26

Aux.Contact Block Holder for FB Series Fusible Disconnect
Switches 100 to 800A

A083B

8.25kV E-Rated Bolt-In Medium Voltage Fuse

E15

AC5, AC6

K21

A083C

8.25kV E-Rated CL-14 Medium Voltage Fuse

E19

Aux.Contact Block Holder for FB Series Fusible Disconnect
Switches 30 to 400A

A100C

1000V Medium Voltage Capacitor Fuse

E38

ACHCD

Auxiliary Contact Block Holder for FB Series Fusible
Disconnect Switches

K19

A100P

Amp-Trap Form 101 Semicond. Fuse, 1000V

D22

ACK

Fork Lift Truck Fuse 1-400A, 125VAC

G18

A120X

Amp-Trap Form 101 Semicond. Fuse, 1200V

D24

ACL

Fork Lift Truck Fuse 30-120A, 125VAC

G18

A130URD

PSC Semicond. Fuse 1250/1300V

D55

AF

Automotive Plastic Body/Silver-Plated Terminal Fuse

C26

A150C

1500V Medium Voltage Capacitor Fuse

E37

AF2

Automotive Plastic Body/Silver-Plated Terminal Fuse

C26

A150X

Amp-Trap Form 101 Semicond. Fuse, 1500V

D25

AF2H

Automotive Fuse Holders

C28

A155B

15.5kV E-Rated Bolt-In Medium Voltage Fuse

E15

AF3

Automotive Plastic Body/Silver-Plated Terminal Fuse

C26

A155B

15.5kV R-Rated Bolt-in Medium Voltage Fuse

E29

AF3H

Automotive Fuse Holders

C28

A155C

15.5kV E-Rated CL-14 Medium Voltage Fuse

E20

AFH20

In-Line Fuse Holders for Blade-Type

C27

A155F

15.5kV E-Rated CS-3 Medium Voltage Fuse

E9

A15QS

Amp-Trap Form 101 Semicond. Fuse, 150V

D2

A240R

2.4kV R-Rated Medium Voltage Fuse

E22

A240T

2.4kV Potential Transformer Fuse

E33

AG

Amp-Trap Class G Fuse, 480V

B18

A250C

2500V Medium Voltage Capacitor Fuse

E39

AJT

Amp-Trap 2000 Class J T-D Fuse,600V

A2

A2D

Amp-Trap 2000 Class RK1 T-D Fuse, 250V

A6

ALS

Fork Lift Truck Fuse 100-500A, 125VAC

G19

A2K

Amp-Trap Class RK1 Fuse, 250V

B16

AOS-S, AOS-Q

Blown Fuse Indicators

J6

A2Y

Amp-Trap Form 600 Fuse, 250V

G13

Application Info.

Circuit Protection Application Info & Glossary

P2

A300C

3000V Medium Voltage Capacitor Fuse

E40

Aquasink Heatsinks

Liquid Cooled Heatsinks

M17

A30QS

Amp-Trap Form 101 Semicond. Fuse, 300V

D4

Liquid Cooled Heatsinks

M19

A3T

Amp-Trap Class T Fuse, 300V

B14

Aquamax Copper
Heatsinks

A430C

4300V Medium Voltage Capacitor Fuse

E41

Liquid Cooled Heatsinks

M21

A480R

4.8kV R-Rated Medium Voltage Fuse

E24

Aquamax Aluminum
Heatsinks

A480T

4.8kV Potential Transformer Fuse

E34

Aquasurf Heatsinks

Liquid Cooled Heatsinks

M20

A4BQ

Amp-Trap 2000 Class L T-D Fuse,600V

A4

Arc Flash Info Center

Arc Flash Info Center (information and resources)

O2

A4BT

Amp-Trap Class L Fuse, 600V

B12

ATDR

Amp-Trap 2000 Class CC T-D Fuse, 600V

A8

A4BX

Welder Protector, 600V

G12

ATM

Amp-Trap Midget Fuse, 600V

C3

A4BY

Amp-Trap Class L Fuse, 600V

B10

ATMR

Amp-Trap Class CC Fuse, 600V

B19

A4J

Amp-Trap Class J Fuse, 600V

B8

ATQ

Amp-Trap Midget Time Delay Fuse, 600V

C2

A500T

5.0kV Potential Transformer Fuse

E34

ATQR

Amp-Trap 2000 Class CC T-D Fuse, 600V

A10

A50P

Amp-Trap Form 101 Semicond. Fuse, 500V

D8

C & CNS

Class CA & CB Canadian Fuse

F22

A50QS

Amp-Trap Form 101 Semicond. Fuse, 500V

D6

C08915P-C08919P

Fuse Clips for Ferrule type Fuses

H58

A550C

5.5kV Medium Voltage Capacitor Fuse

E42

CBC Modular Bar Contactor (80 - 6200A)

L12

A60C

Low Voltage Capacitor Fuse 600V

G11

CBC Modular Bar
Contactors

A60Q

Amp-Trap Form 101 Semicond. Fuse, 600V

D10

CC 1051 CP

gRB 20x127 1000V DC Rated Special Purpose Round
Body Fuse

G22

A60X

Amp-Trap Form 101 Semicond. Fuse, 600V

D11

CC 1051 CP

Amp-Trap 2000 Class RK1 T-D Fuse, 600V

A6

gRB 36x127 1000V DC Rated Special Purpose Round
Body Fuse

G23

A6D
A6K

Amp-Trap Class RK1 Fuse, 600V

B16

CC 12 SRG 72 QF

1200V DC Rated Special Purpose Square Body Fuse

G34

A6T

Amp-Trap Class T Fuse, 600V

B14

CC 1500 CP

Amp-Trap Form 600 Fuse, 600V

G13

1500V gRC 20x190 DC Rated Special Purpose Round
Body Fuse

G25

A6Y
A70P

Amp-Trap Form 101 Semicond. Fuse, 700V

D18

CC 1500 CP

G26

A70Q

Amp-Trap Form 101 Semicond. Fuse, 700V

D20

1500V gRC 36x190 DC Rated Special Purpose Round
Body Fuse

Automobile Fuse
AFH30

In-Line Fuse Holders for Blade-Type

C27

Automobile Fuse

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

INDEX 3

Advisor
Part Number		

Description		

Index

INDEX

Page

Part Number		

Description		

Page

CC 1500 CP gRB

1500V gRB 20x127 DC Rated Special Purpose Round
Body Fuse

G24

Dual Base Plate
Heatsinks

Air Cooled Heatsinks

M13

CC 1500 CP gRD

1500V gRD 20x127 DC Rated Special Purpose Round
Body Fuse

G24

EAFB..

Enclosed Disconnect Switch

K33

EAFC..

Enclosed Disconnect Switch

K33

1500V gRD 36x190 DC Rated Special Purpose Round
Body Fuse

G26

EAFS..

Enclosed Disconnect Switch

K33

1000V gRB 20x127 DC Rated Special Purpose Round
Body Fuse

G24

EASC..

Enclosed Disconnect Switch

K33

EBFB..

Enclosed Disconnect Switch

K33

CC 1591 CP

1500V gRC 20x190 DC Rated Special Purpose Round
Body Fuse

G25

EBFC..

Enclosed Disconnect Switch

K33

EBFS..

Enclosed Disconnect Switch

K33

CC 1591 CP

1500V gRC 36x190 DC Rated Special Purpose Round
Body Fuse

G26

EBSC..

Enclosed Disconnect Switch

K33

ECFB..

Enclosed Disconnect Switch

K33

CC 20 SRC 120 QF

2000V DC Rated Special Purpose Square Body Fuse

G35

ECFC..

Enclosed Disconnect Switch

K33

CC 20 SRD 122 QF

1800V, 2000V DC Rated Special Purpose Square Body
Fuse

G36

ECFS..

Enclosed Disconnect Switch

K33

CC 35 gRB 600 QF

3500V DC Rated Special Purpose Square Body Fuse

G37

ECSC..

Enclosed Disconnect Switch

K33

CC 4.421 CP gLB

DC Rated, special purpose round body fuse, 440V

G20

EDFS..

Enclosed Disconnect Switch

K33

CC 40 gRB 600 QF

4000V DC Rated Special Purpose Square Body Fuse

G37

EFFB..

Enclosed Disconnect Switch

K33

CC 40 gRD 600 QF

4000V DC Rated Special Purpose Square Body Fuse

G37

EFFC..

Enclosed Disconnect Switch

K33

CC 4000 CP gRC

4000V gRC 36x400 DC Rated Special Purpose Round
Body Fuse

G27

EFFS..

Enclosed Disconnect Switch

K33

EFSC..

Enclosed Disconnect Switch

K33

CC 6,621 CP gRB

660V DC Rated, Special Purpose Round Body Fuse

G21

EGFB..

Enclosed Disconnect Switch

K33

CC 6.6 gRB 123

660V DC Rated Special Purpose Square Body Fuse

G31

EGFC..

Enclosed Disconnect Switch

K33

CC 6.6 gRB 2123

660V DC Rated Special Purpose Square Body Fuse

G33

EGFS..

Enclosed Disconnect Switch

K33

CC 7,5 gRB 123

750V DC Rated Special Purpose Square Body Fuse

G31

EGSC..

Enclosed Disconnect Switch

K33

CC 7,5 gRB 2123

750V DC Rated Special Purpose Square Body Fuse

G33

EHFB..

Enclosed Disconnect Switch

K33

CC 7,5 gRC 120

750V, 900V DC Rated Special Purpose Square Body Fuse

G28

EHFC..

Enclosed Disconnect Switch

K33

CC 7,5 gRC 121

750V, 900V DC Rated Special Purpose Square Body Fuse

G29

EHFS..

Enclosed Disconnect Switch

K33

CC 7,5 gRC 122

750V, 900V DC Rated Special Purpose Square Body Fuse

G30

EHSC..

Enclosed Disconnect Switch

K.33

CC 7,5 gRC 123

750V, 900V DC Rated Special Purpose Square Body Fuse

G31

EJFS..

Enclosed Disconnect Switch

K33

CC 7,5 gRC 2122

700V, 900V DC Rated Special Purpose Square Body Fuse

G32

Electrical Services

Electrical Services (Consulting, Training, Resources)

O3

CC 7,5 gRC 2123

750V, 900V DC Rated Special Purpose Square Body Fuse

G33

Embedded Heatpipes

Air Cooled Heatpipes

M16

CC 7,5 gRD 122

750V, 900V DC Rated Special Purpose Square Body Fuse

G30

ES Series

Fusible Shunt Trip Engineered Disconnect Switch

K37

CC 7,5 gRD 123

750V DC Rated Special Purpose Square Body Fuse

G31

Extrusion Heatsinks

Air Cooled Heatsinks

M14

CC 7,5 gRD 2122

700V, 900V DC Rated Special Purpose Square Body Fuse

G32

Fabfin Heatsinks

Air Cooled Heatsinks

M2

CCNL

Shorting Links Kit for FB Series Fusible Disconnect
Switches

K19

FBCC, FBJ Series

Fusible Disconnect Switch 30 to 60A

K19

FBJ, FBL Series

Fusible Disconnect Switch 100 to 800A

K20

CEX

CEX Field Excitation Contactors (80 - 5000A)

L13

FBJ Series

Fusible Disconnect Switch 30 to 400A

K21

CNL

Fork Lift Truck Fuse 35-500A, 32V AC/DC

G18

600V In-Line Breakaway Fuse Holders

H33

CNN

Fork Lift Truck Fuse 10-800A

G18

FEB, FEC, FEX, FEY,
FEBN

Colomix 71

Colomix 71 (Blow Out Cage)

L14

FES

Canadian Class C Fuse

F20

Cooling Systems

Thermal Management Cooling Systems

M23

FESC

Canadian Class C Fuse

F20

Copper Heatsinks

Air Cooled Heatsinks

M12

FESF

Canadian Class C Fuse

F20

COU,COW,COX,COY

Box Cover Units

J2

FH..

Semiconductor Fuse Blocks

H44

COY-B, CSY-L, CSY-RL

Box Cover Units

J2

FSB1, FSB2

In-Line Fuse Holder Boot

H34

CP…A

Amp-Trap Cable Protectors, 600V, Al Cable

G2

FSFE

Automotive SFE fuse

C23

CP…C

Amp-Trap Cable Protectors, 600V, Cu Cable

G2

FSLBS Series

Load Break Disconnect Switch

K2

CRN & CRS

Class H Canadian Fuse

F25

FSM

Multi-Meter Fuse, 1000V

C7

CRU,CRW,CRX,CRY

Box Cover Units

J2

FS-POP

Free Standing Floor Display

J12

CSU,CSW,CSX,CSY

Box Cover Units

J2

FSPDB

Finger-Safe Power Distribution Blocks

I2

CTY, CCY, CKA

Box Cover Units

J2

FSSC

Non-Fused Load Break Disconnect Switch

K6

DCT

1000V DC Ferrule Fuse

C6

Fuse Control Program

Get Control of Your Inventory

O5

DFC-1...DFC-12I

Dead Front Fuse Covers

H55

G

Standard Plug Fuse-Non T-D CSA

B24

DFC3M, DFC3LP, DRM

Dead Front Safety Pullers

H57

GAB

1/4” x 1” Ceramic Body Fuse

C20

CC 1500 CP gRD
CC 1551 CP gRB

INDEX 4

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Advisor
Part Number		

Description		

INDEX

Page

Index

Part Number		

Description		

Page

GDG

5 mm x 20 mm Glass Body Fuse

C18

Hollowfin Heatsinks

Air Cooled Heatsinks

M9

GDG-V

5 mm x 20 mm Glass Body Fuse

C18

HP6J

600V DC Photovoltaic Protection Fuse

G40

GDL

1/4”x1-1/4” Glass Body Time Delay Fuse

C15

HP6M

600V DC Photovoltaic Protection Fuse

G38

GDL-V

1/4”x1-1/4” Glass Body Time Delay Fuse

C15

HP10M

1000V DC Photovoltaic Protection Fuse

G39

GFN

Midget Indicating Fuse

C9

HSE - HSD

Electrolytic Cell DC Disconnect Switch (Hundt and Weber)

L11

GGA

5 mm x 20 mm Glass Body Fuse

C17

HSJ

High Speed / Class J

B6

GGA-V

5 mm x 20 mm Glass Body Fuse

C17

HSP Series

1/4”x1-1/4” Glass Body Time Delay Fuse

C16

Selector Handles for FB Series Fusible Disconnect
Switches 30 to 60A

K19

GGC
GGC-V

1/4”x1-1/4” Glass Body Time Delay Fuse

C16

HSP Series

K20

GGM

5 mm x 20 mm Glass Body Fuse

C16

Selector Handles for FB Series Fusible Disconnect
Switches 100 to 800A

GGM-V

5 mm x 20 mm Glass Body Fuse

C16

Midget Glass/Ceramic Body Fuse

C8

3.6kV AC / DC MV Changeover Disconnect (HUVS Range
- Berg)

L3

GGU

HUVS Range Berg
3.6kV AC / DC

GGX

1/4” x 1” Glass Body Fuse

C20

IL Indicator

Blown Fuse Indicators

J6

GMS

Alarm Indicating Telecommunications Fuse

G17

Integrated Heatsinks

Air Cooled Heatsinks

M11

GP

Standard Plug Fuse “P” Type Non T-D CSA

B24

J136-J646

Class J Fuse Reducers

J3

GPM

Panel Mount Fuse Holders

H37

MC2R3E..

Protistor Microswitches

J10

GSA

1/4”x1-1/4” Ceramic Body Time Delay Fuse

C15

MC3E..

Protistor Microswitch

J10

GSA-V

1/4”x1-1/4” Ceramic Body Time Delay Fuse

C15

MCR3E..

Protistor Microswitch

J10

GSB

5 mm x 20 mm Glass Body Fuse

C18

MC 36

PSC Microswitch

J7

GSB-V

5 mm x 20 mm Glass Body Fuse

C18

MC 6,3

PSC Microswitch

J7

GSC

5 mm x 20 mm Glass/Ceramic Body Fuse

C17

MFD, MFD300

Miniature Fuse Display

J12

GSC-V

5 mm x 20 mm Glass/Ceramic Body Fuse

C17

Mixed Metals Heatsinks

Air Cooled Heatsinks

M10

GSD

5 mm x 20 mm Ceramic Body Fuse

C19

MRF, MRT

Radial Lead Micro Fuse

C22

GSD-V

5 mm x 20 mm Ceramic Body Fuse

C19

MS 4L..

PSC Microswitch

J7

GSF

5 mm x 20 mm Ceramic Body Fuse

C19

MS PA..

PSC Microswitch

J7

GSF-V

5 mm x 20 mm Ceramic Body Fuse

C19

MS 3V..

PSC Microswitch

J7

GSFC, GSFC-M

Spare Fuse Cabinets

J12

MS 7V..

PSC Microswitch

J7

GSGFD

Glass Fuse Display Rack

J12

NIT & NS

HRCII Canadian Fuse BS88

F23

GSL

Standard Plug Fuse Rejection T-D UL

B24

NORD DC Disconnect
Switch

1500V DC Disconnect Switch (Fouilleret NORD)

L7

GSMR

Midget and Class CC Fuse Display Rack

J12

NRN & NRS

Class H Canadian Fuse

F24

GSR-V

7.1mm Plastic Body Fuse

C20

Open Style PDBs

Open Style PDBs 62000-69000

I4

GT

Standard Plug Fuse Low Temp T-D UL

B24

OT

One-Time Fuse, Class K-5, 250V

B20

GTL

Standard Plug Fuse T-D UL

B24

OTM

One-Time Midget Fuse, 250V

C5

GW

Standard Plug Fuse-Non T-D UL

B24

OTN

O-T Fuse, Class K-5, (Canadian “P”) 250V

B20

HA Range Berg 1500V

1500V DC LV Disconnect Switch (HA Range - Berg)

L2

OTS

One-Time Fuse,Class K-5, 600V

B20

HADB1, HADB2

Direct Front Operation Handle for FB Series Fusible
Disconnect Switches

K19

P243, P266, P292

Semiconductor Fuse Blocks

H44

HADB4

Pistol Handle for FB Series Fusible Disconnect Switches

K21

PCF

PC Mount Fast-Acting Fuse

C11

HADB6

NFPA79 Front Operation Kit for FB Series Fusible
Disconnect Switches

K19

PCS

PC Mount Semiconductor Protection Fuse

C12

PCT

PC Mount Time Delay Fuse

C13

HADSS200

Direct mount black handle

N18

PIQ Quiz

Circuit Protection Quizzes & Downloads

O7

HAF-..

Cable Flange Operated Handle for FB Series Fusible
Disconnect Switches

K21

Power Electronics

Power Electronics Solutions

O10

Press Pack Coolers

Press Pack Coolers

M22

HAS Range Berg 12kV

12kV AC MV Disconnect Switch (HAS Range - Berg)

L4

PS 20x127

Fuse Holders & no-load disconnectors

H48

L5

R-Tools

3D Heatsink Thermal Modeling

M26

L6

R132 - R642

Fuse Reducers Class RK1& RK5

J3

Renewable Fuse, 250V

B22

HAS Range Berg 24kV
HAS Range Berg 36kV

24kV AC MV Disconnect Switch (HAS Range - Berg)
36kV AC MV Disconnect Switch (HAS Range - Berg)

Heatpipes

Air Cooled Heatpipes

M15

RF

Heatsinks. Air Cooled

Air Cooled Heatsinks

M2

RFS

Renewable Fuse, 600V

B22

M17

RL

Renewable Links, 250V, for RF Fuse

B22

RLS

Renewable Links, 600V, for RFS Fuse

B22

Heatsinks, Liquid
Cooled

Liquid Cooled Heatsinks

HGPB, HGPR

External handle for Surge Switch

N18

SBS

1-3/8”x13/32” Fuse, 600V

C10

HGPB4, HGPR4

External handle for Surge Switch

N18

SC

Non-Fused Load Break Disconnect Switch

K9

High Power Test Lab

HIgh Power Test Lab Overview & Contacts

O6

SE

IEC Back-Up Fuse Links

E49

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

INDEX 5

Advisor
Part Number		

Description		

Page

Select-A-Fuse

Select-A-Fuse Software

O9

SFRB

In-Line Fuse Holder for FSFE fuse

C23

SFRG

In-Line Fuse Holder for FSFE/2AG fuse

SFRT
SFRU

In-Line Fuse Holder for FSFE fuse
In-Line Fuse Holder for FSFE fuse

INDEX

Index

Part Number		

Description		

Page

TS..

Terminal Shroud Kits for Fusible Disconnect Switches 100
to 800A

K20

C23

TS200SS, TS2004SS

Terminal Shields for 200kA Surge Switch

N18

C23

U09311

Polycarbonate End Barriers for PDB Adder Blocks

I5

C23

U09705

Polycarbonate End Barriers for PDB Adder Blocks

I7

U09911

Polycarbonate End Barriers for PDB Adder Blocks

I9

SG200-10, SG320-10,
SG400-10

Shafts for 200kA Surge Switch

N18

US12PJMP

12 Pole Jumper Bar

H3

SHR

In-Line Fluorescent Light Fuse Holder for SLR/SMF

C24

US14, US22

UltraSafe Fuse Holders for 14x51 & 22x58 Fuses

H9

SI

IEC Back-Up Fuse Links

E49

US3J

UltraSafe Fuse Holders for Class J 30A

H7

SL

Shorting Links Kit for FB Series Fusible Disconnect
Switches 30 to 60A

K19

US3JN, US6JN

Ultrasafe Fuse Holder 1-Pole Neutral for Class J Fuses

H7

US3JPAK, US6JPAK

Pin-Tie Assembly Kits for use with US3J, US6J

H7

Shorting Links Kit for FB Series Fusible Disconnect
Switches 100 to 800A

K20

US6J

UltraSafe Fuse Holders for Class J 60A

H7

SLR

In-Line Fluorescent Light Fuse 1/2-15A

C24

USCC

UltraSafe Fuse Holders for Class CC Fuses

H3

SMF

In-Line Fluorescent Light Fuse 3/10-10A

C24

USCC-DC

UltraSafe Fuse Holders for Class CC Fuses DC Rated

H3

SMG

4 1/2”x14 1/2”mm Glass Body Fuse

C21

USFM

UltraSafe Fuse Module Compact 45mm width

H5

SMG-V

4 1/2”x14 1/2”mm Glass Body Fuse

C21

USM

UltraSafe Fuse Holders for Midget Fuses

H3

Solar Power Solutions

Solar Power Circuit Protection Solutions

O11

USM-DC

UltraSafe Fuse Holders for Midget Fuses DC Rated

H3

Soule PBD DC
Disconnect Switch

2000V DC Disconnect Switch (Soule PBD)

L9

USN

UltraSafe Fuse Holder Neutral Link Accessory

H3

USPTH

UltraSafe Fuse Holder Pin Tie Accessory

H3

SS200-5 - SS500-10

Shafts for FB Series Fusible Disconnect Switches 30 to
60A

K19

VSP

Surge Suppression Fuse

N16

Wind Power Solutions

Wind Power Circuit Protection Solutions

O12

SS200-10 - SS500-12

Shafts for FB Series Fusible Disconnect Switches 100 to
800A

K20

SS, SS200-4

Surge Switch, 200kA

N18

ST

Surge-Trap Modular SPD

N3

STG

4 1/2”x14 1/2”mm Glass Body Fuse

C21

STG-V

4 1/2”x14 1/2”mm Glass Body Fuse

C21

STP

Surge-Trap Pluggable SPD

N5

STT

Surge-Trap Type 1 SPD

N7

STXP

Surge-Trap Type 1 XP Series SPD

N11

STXR

Surge-Trap Type 1 XR Series SPD

N9

STXT

Surge-Trap Type 1 XT Series SPD

N13

SX

Non-Fused Load Break Disconnect Switch

K7

SXDC

Non-Fused Load Break Disconnect Switch

K8

TA

Blown Fuse Indicators

J5

TBB

1-Phase input Power Terminal

H3

TD

Standard Plug Fuse “D” Type Non T-D CSA

B24

SL

Technical Services

Technical Services Support (Contacts and Resources)

O13

TGL

Telecommunication Fuse 70-800A, 170VDC

G15

TGN

Telecommunication Fuse 1-600A, 170VDC

G15

TGS

Telecommunication Fuse 1-70A, 170VDC

G15

Thermal Management

Product & Materials

M24

TI

Blown Fuse Indicators

J5

TL..

Terminal Lugs Kit for Fusible Disconnect Switches 100 to
800A

K20

TL..

Terminal Lugs Kit for Fusible Disconnect Switches 30 to
400A

K21

TPMOV

Thermal Protective Metal Oxide Varistor

N14

TR

Tri-onic Class RK5 Time Delay Fuse,250V

B2

TRM

Tri-onic Midget Time Delay Fuse, 250V

C4

TRS

Tri-onic Class RK5 Time Delay Fuse,600V

B2

TRS-RDC

Tri-onic DC Time Delay Fuse, 600V

B4

INDEX 6

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

Main production sites
Industrial or commercial branch

A World Leader
in the field of
electrical protection

A Global Player
Since its foundation in 1892,
MERSEN has built an international
reputation by creating subsidiaries
on all continents. Today with
industrial and commercial plants
scattered in more than 30
countries, agencies

Mersen USA
374 Merrimac Street
Newburyport, MA 01950
U.S.A.
T : 978 462 6662
F : 978 462 0181

Mersen FRANCE
1, rue Jean Noel
F-69100 Villeurbanne
France
T : +33 (0)4 72 22 66 11
F : +33 (0)4 72 22 67 13

and representatives in more than
70 countries and 250 commercial
contacts throughout the world,
MERSEN offers its customers
everywhere reliable, high
technology products and services
backed by its expert technicians.

Mersen TORONTO
88 Horner Avenue
Toronto, Ontario
Canada M8Z 5Y3
T : 416 252 9371
F : 416 252 6572

Mersen MISSISSAUGA
6220 Kestrel Roas
Mississauga, Ontario,
Canada L5T 1Y9
T : 905 795 0077
F : 905 795 2508

us-ferrazshawmut.mersen.com
This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com

This document provided by Barr-Thorp Electric Co., Inc. 800-473-9123

www.barr-thorp.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2010:10:05 15:14:10-04:00
Creator                         : Adobe InDesign CS5 (7.0.2)
Modify Date                     : 2011:01:25 17:51:32-05:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Instance ID                     : uuid:c14eb0e0-568f-4912-a454-f778bbaa1ded
Document ID                     : xmp.did:8F7BD21584C2DF11B37CB09C41B547DA
Original Document ID            : adobe:docid:indd:a0cef98b-6445-11df-8f8a-9be765480219
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:DF0DBD1584C2DF11B37CB09C41B547DA
Derived From Document ID        : xmp.did:D4A0528801C1DF1199FEA660E7ED6598
Derived From Original Document ID: adobe:docid:indd:a0cef98b-6445-11df-8f8a-9be765480219
Derived From Rendition Class    : default
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:C301D4C6BF89DF119E28E94B53AEBAEC, xmp.iid:C401D4C6BF89DF119E28E94B53AEBAEC, xmp.iid:C501D4C6BF89DF119E28E94B53AEBAEC, xmp.iid:C601D4C6BF89DF119E28E94B53AEBAEC, xmp.iid:2B422DA3D9C0DF1199FEA660E7ED6598, xmp.iid:2C422DA3D9C0DF1199FEA660E7ED6598, xmp.iid:82B43231E4C0DF1199FEA660E7ED6598, xmp.iid:8CD8B4AEEAC0DF1199FEA660E7ED6598, xmp.iid:689AF375F0C0DF1199FEA660E7ED6598, xmp.iid:87B77213F1C0DF1199FEA660E7ED6598, xmp.iid:7131A35BF9C0DF1199FEA660E7ED6598, xmp.iid:E85EF5D5FBC0DF1199FEA660E7ED6598, xmp.iid:843E876000C1DF1199FEA660E7ED6598, xmp.iid:2D4750B000C1DF1199FEA660E7ED6598, xmp.iid:FC24B0C700C1DF1199FEA660E7ED6598, xmp.iid:E61F6DD500C1DF1199FEA660E7ED6598, xmp.iid:8DD4B14301C1DF1199FEA660E7ED6598, xmp.iid:8ED4B14301C1DF1199FEA660E7ED6598, xmp.iid:D4A0528801C1DF1199FEA660E7ED6598, xmp.iid:6BE5E61904C1DF11A1DDBA74D50F4AFA, xmp.iid:6CE5E61904C1DF11A1DDBA74D50F4AFA, xmp.iid:6DE5E61904C1DF11A1DDBA74D50F4AFA, xmp.iid:C8988E7F04C1DF11A1DDBA74D50F4AFA, xmp.iid:B4C6AD8C06C1DF11A1DDBA74D50F4AFA, xmp.iid:87B07BB606C1DF11A1DDBA74D50F4AFA, xmp.iid:88B07BB606C1DF11A1DDBA74D50F4AFA, xmp.iid:D621812C07C1DF11A1DDBA74D50F4AFA, xmp.iid:1BFE02C208C1DF11A1DDBA74D50F4AFA, xmp.iid:1CFE02C208C1DF11A1DDBA74D50F4AFA, xmp.iid:D676503A09C1DF11A1DDBA74D50F4AFA, xmp.iid:DF784C87C9C1DF119639C32D3D0929EF, xmp.iid:03E4AA4FCAC1DF119639C32D3D0929EF, xmp.iid:92C094E6D3C1DF119CBAC10B2A8992B9, xmp.iid:9769493FD4C1DF119CBAC10B2A8992B9, xmp.iid:33396B45D4C1DF119CBAC10B2A8992B9, xmp.iid:34396B45D4C1DF119CBAC10B2A8992B9, xmp.iid:DF4984FE70C2DF11A2DC9D3FF8956162, xmp.iid:3E69EF6D71C2DF11A2DC9D3FF8956162, xmp.iid:F809F57971C2DF11A2DC9D3FF8956162, xmp.iid:7CD5859471C2DF11A2DC9D3FF8956162, xmp.iid:37A782AA71C2DF11A2DC9D3FF8956162, xmp.iid:EEF0B48083C2DF11B37CB09C41B547DA, xmp.iid:34DAA30184C2DF11B37CB09C41B547DA, xmp.iid:DF0DBD1584C2DF11B37CB09C41B547DA, xmp.iid:8F7BD21584C2DF11B37CB09C41B547DA, xmp.iid:0B44868E84C2DF11B37CB09C41B547DA, xmp.iid:2BB8A8FDB7C5DF11B093FE2268D4075A, xmp.iid:E54E4332B8C5DF11B093FE2268D4075A, xmp.iid:2EDCE4858CC6DF11A7D4FAC589F88948, xmp.iid:E150C69F8CC6DF11A7D4FAC589F88948, xmp.iid:BFD551C3B3CCDF11A7D2A0F9E83D0301, xmp.iid:04DE95D4B3CCDF11A7D2A0F9E83D0301, xmp.iid:4E6E8381B4D0DF11BFA386C45DB9CC6F, xmp.iid:07A9C5ABB4D0DF11BFA386C45DB9CC6F
History When                    : 2010:07:07 08:18:58-04:00, 2010:07:07 08:18:58-04:00, 2010:07:07 08:19:13-04:00, 2010:07:07 08:19:13-04:00, 2010:09:15 10:58:02-04:00, 2010:09:15 10:58:02-04:00, 2010:09:15 12:13:35-04:00, 2010:09:15 13:00:03-04:00, 2010:09:15 13:41:24-04:00, 2010:09:15 13:45:49-04:00, 2010:09:15 14:45:06-04:00, 2010:09:15 15:02:50-04:00, 2010:09:15 15:35:20-04:00, 2010:09:15 15:37:34-04:00, 2010:09:15 15:38:13-04:00, 2010:09:15 15:38:36-04:00, 2010:09:15 15:41:41-04:00, 2010:09:15 15:43:36-04:00, 2010:09:15 15:43:37-04:00, 2010:09:15 16:02-04:00, 2010:09:15 16:02:57-04:00, 2010:09:15 16:03:24-04:00, 2010:09:15 16:04:50-04:00, 2010:09:15 16:19:31-04:00, 2010:09:15 16:20:41-04:00, 2010:09:15 16:22:15-04:00, 2010:09:15 16:23:59-04:00, 2010:09:15 16:35:20-04:00, 2010:09:15 16:38:09-04:00, 2010:09:15 16:38:42-04:00, 2010:09:16 15:35:14-04:00, 2010:09:16 15:40:50-04:00, 2010:09:16 16:49:29-04:00, 2010:09:16 16:51:58-04:00, 2010:09:16 16:52:08-04:00, 2010:09:16 17:26:57-04:00, 2010:09:17 11:34-04:00, 2010:09:17 11:37:07-04:00, 2010:09:17 11:37:27-04:00, 2010:09:17 11:38:12-04:00, 2010:09:17 11:38:49-04:00, 2010:09:17 13:46:30-04:00, 2010:09:17 13:50:06-04:00, 2010:09:17 13:50:40-04:00, 2010:09:17 13:50:40-04:00, 2010:09:17 13:54:02-04:00, 2010:09:21 15:39:46-04:00, 2010:09:21 15:41:15-04:00, 2010:09:22 17:01:08-04:00, 2010:09:22 17:01:52-04:00, 2010:09:30 12:57:09-04:00, 2010:09:30 12:57:38-04:00, 2010:10:05 15:12:33-04:00, 2010:10:05 15:13:43-04:00
History Software Agent          : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0
History Changed                 : /, /metadata, /metadata, /, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata
Metadata Date                   : 2011:04:07 12:20:43-06:00
Creator Tool                    : Adobe InDesign CS5 (7.0.2)
Doc Change Count                : 7956
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Layout                     : SinglePage
Page Mode                       : UseOutlines
Page Count                      : 548
EXIF Metadata provided by EXIF.tools

Navigation menu