100773 Catalog

2014-07-05

: Pdf 100773-Catalog 100773-Catalog 785901 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 8

6-1
© 2012 Schneider Electric
All Rights Reserved
6SURGE PROTECTIVE DEVICES
Table of Contents
Section 6
Surge Protective Devices
EMA/EBA SPDs,
pages 6-2, 6-3, & 6-4
Commercial Applications
Panelboards &
Switchboards, page 6-5
Retrofit,
page 6-5
Residential & Light
Commercial Applications
Whole House SPDs,
page 6-8
QO/HOM SPDs,
page 6-8
Nipple Mounted SPDs,
pages 6-6, 6-7, and 6-8
Externally Mounted Surge Protective Devices
External Modular SPDs—EMA SPDs 6-2
External Modular L-L Enhanced SPDs 6-3
External Brick Assembly SPDs—EBA SPDs 6-3
Replacement Modules 6-4
Internally Mounted Surge Protective Devices—New Construction
Panelboards—Refer to 9-1
Switchboards and Switchgear—Refer to 11-1
Model 6 Motor Control Centers—Refer to 17-1
IPaCS—Refer to 10-1
Busway 12-1
Internally Mounted Surge Protective Devices—Retrofit
Internally Mounted SPD—Retrofit 6-5
OEM/Assembler Kits 6-6
Nipple-Mounted Surge Protective Devices
SDSA3650 SPDs 6-6
HWA SPDs 6-7
SDSA1175 SPDs 6-7
Mounting Brackets and Flush Mount Kits 6-7
XR SPDs 6-8
Residential Surge Protective Devices
Whole House SPDs 6-8
Whole House Accessories 6-8
QO™, NQ, and Homeline™ Loadcenter SPDs 6-8
www.schneider-electric.us
6SURGE PROTECTIVE DEVICES
6-2 © 2012 Schneider Electric
All Rights Reserved
Surge Protective
Devices
Externally Mounted Surge Protective Devices
Class 1310 / Refer to Catalog 6671CT9701
a208Y/120 series also applies to the following voltage 220Y/127.
bCan be used on 4-wire or 3-wire grounded neutral system.
c480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240.
dNot available in stainless steel for 320 and 480 kA
Externally Mounted Surge Protective Devices
Surgelogic™ offers a full range of externally mounted SPDs. These units are designed to provide surge suppression from service entrance panels to
point-of-use equipment.
US and Canadian UL® Listed to UL 1449 3rd Edition and UL 1283 5th Edition. Complies with requirements of NEC® Article 285 and CSA 22.2
No. 8-M1986 as appropriate. Complies with UL 96A 12th Edition Master Label requirements for Lightning Protection Systems.
10 year product warranty
10 modes of protection
200 kA SCCR
EMI/RFI filtering
Audible alarm with enable/disable switch,
dry contacts, and surge counter standard
Indicator LEDs; normal (green) and fault condition (red) for each phase
UL 1449 Type 2 (or Type 1 with optional suffix in catalog number)
External SPD Options:
Sine Wave Tracking Module. Sine Wave Tracking (SWT) circuitry provides enhanced EMI/RFI filtering of -54 dB at 100 kHz and establishes the power surge
clamping window relative to the sine wave voltage to increase performance at distribution and branch panel applications.
Type 1. UL 1449 Type 1 SPDs can be located at any point in the electrical system, on the line or load side of the equipment overcurrent device.
Integral Switch. The integral switch provides a mechanical means to electrically isolate the entire surge suppressor before opening the enclosure door to facilitate
servicing of the unit’s components.
Remote Monitor. This option displays the alarm status of the surge protective device up to 1000 feet from the unit.
Flush Mount Kits. Flush mounting kits can be used on 120–240 kA EMA and EBA series devices. Devices with integral switch require a 20 inch flush mounting collar.
External Modular Assembly (EMA) SPDs
EMA SPD products feature a design based on individual phase modules for a flexible, cost effective way to achieve superior surge suppression at every
level of the electrical distribution system. Modularity results in lower life cycle costs and fast, easy service or replacement.
External Modular SPD
with Integral Switch
External Modular SPD
with Sine Wave Tracking Module
External Modular
High-Resistance Ground SPD
Table 6.1: EMA SPDs
Service Voltage Peak Surge Current
Rating per Phase (kA)
NEMA 3R
Cat. No. $ Price NEMA 4X Stainless
Steel Cat. No. $ Price
120/240 V, 1-phase,
3-wire + ground
120 TVS1EMA12A( ) 4547.00 TVS1EMA12S( ) 5964.00
160 TVS1EMA16A( ) 4997.00 TVS1EMA16S( ) 6414.00
240 TVS1EMA24A( ) 7421.00 TVS1EMA24S( ) 8838.00
320 TVS1EMA32A( ) 9962.00 TVS1EMA32S( ) 11379.00
480 TVS1EMA48A( ) 14798.00 TVS1EMA48S( ) 16215.00
208Y/120 V, 3-phase,
4-wire + ground ab
Wye
120 TVS2EMA12A( ) 4760.00 TVS2EMA12S( ) 6177.00
160 TVS2EMA16A( ) 5231.00 TVS2EMA16S( ) 6648.00
240 TVS2EMA24A( ) 7782.00 TVS2EMA24S( ) 9200.00
320 TVS2EMA32A( ) 10431.00 TVS2EMA32S( ) 11849.00
480 TVS2EMA48A( ) 15522.00 TVS2EMA48S( ) 16940.00
240/120 V, 3-phase,
4-wire + ground
High-leg Delta
120 TVS3EMA12A( ) 4760.00 TVS3EMA12S( ) 6177.00
160 TVS3EMA16A( ) 5231.00 TVS3EMA16S( ) 6648.00
240 TVS3EMA24A( ) 7782.00 TVS3EMA24S( ) 9200.00
320 TVS3EMA32A( ) 10431.00 ——
480 TVS3EMA48A( ) 15522.00 ——
240 V, 3-phase,
3-wire + ground
Delta
120 TVS6EMA12A( ) 4760.00 TVS6EMA12S( ) 6177.00
160 TVS6EMA16A( ) 5231.00 TVS6EMA16S( ) 6648.00
240 TVS6EMA24A( ) 7782.00 TVS6EMA24S( ) 9200.00
320 TVS6EMA32A( ) 10431.00 TVS6EMA32S( ) 11849.00
480 TVS6EMA48A( ) 15522.00 TVS6EMA48S( ) 16940.00
480Y/277 V, 3-phase,
4-wire + ground bc
Wye
120 TVS4EMA12A( ) 4973.00 TVS4EMA12S( ) 6390.00
160 TVS4EMA16A( ) 5468.00 TVS4EMA16S( ) 6885.00
240 TVS4EMA24A( ) 8147.00 TVS4EMA24S( ) 9564.00
320 TVS4EMA32A( ) 10904.00 TVS4EMA32S( ) 12321.00
480 TVS4EMA48A( ) 16250.00 TVS4EMA48S( ) 17667.00
480Y/277 V, 3-phase,
3-wire + ground
High-Resistance Ground
120 TVS4HEMA12A( ) 4973.00 TVS4HEMA12S( ) 6390.00
160 TVS4HEMA16A( ) 5468.00 TVS4HEMA16S( ) 6885.00
240 TVS4HEMA24A( ) 8147.00 TVS4HEMA24S( ) 9564.00
320 TVS4HEMA32A( ) 10904.00 TVS4HEMA32S( ) 12321.00
480 TVS4HEMA48A( ) 16250.00 TVS4HEMA48S( ) 17667.00
480 V, 3-phase,
3-wire + ground,
Delta
120 TVS5EMA12A( ) 4973.00 TVS5EMA12S( ) 6390.00
160 TVS5EMA16A( ) 5468.00 TVS5EMA16S( ) 6885.00
240 TVS5EMA24A( ) 8147.00 TVS5EMA24S( ) 9564.00
320 TVS5EMA32A( ) 10904.00 TVS5EMA32S( ) 12321.00
480 TVS5EMA48A( ) 16250.00 TVS5EMA48S( ) 17667.00
600Y/347 V, 3-phase,
4-wire + ground b
Wye
120 TVS8EMA12A( ) 5220.00 TVS8EMA12S( ) 6638.00
160 TVS8EMA16A( ) 5714.00 TVS8EMA16S( ) 7131.00
240 TVS8EMA24A( ) 8528.00 TVS8EMA24S( ) 9945.00
320 TVS8EMA32A( ) 11399.00 TVS8EMA32S( ) 12816.00
480 TVS8EMA48A( ) 17012.00 TVS8EMA48S( ) 18429.00
600Y/347 V, 3-phase,
3-wire + ground
High-Resistance Ground
120 TVS8HEMA12A( ) 5220.00 TVS8HEMA12S( ) 6638.00
160 TVS8HEMA16A( ) 5714.00 TVS8HEMA16S( ) 7131.00
180 TVS8HEMA18A( ) 8528.00 TVS8HEMA18S( ) 9945.00
240 TVS8HEMA24A( ) 11399.00 TVS8HEMA24S( ) 12816.00
320 TVS8HEMA32A( ) 17012.00 TVS8HEMA32S( ) 18429.00
600 V, 3-phase,
3-wire + ground,
Delta
120 TVS9EMA12A( ) 5220.00 TVS9EMA12S( ) 6638.00
160 TVS9EMA16A( ) 5714.00 TVS9EMA16S( ) 7131.00
180 TVS9EMA18A( ) 8528.00 TVS9EMA18S( ) 9945.00
240 TVS9EMA24A( ) 11399.00 TVS9EMA24S( ) 12816.00
320 TVS9EMA32A( ) 17012.00 TVS9EMA32S( ) 18429.00
External Modular Options ( ) $ Price
(1) UL 1449 Type 1 0.00
(I) dIntegral Switch 738.00
(SWT) Sine Wave Tracking Module (not applicable for Delta or HRG) 750.00
(I1) dUL 1449 Type 1 and Integral Switch 738.00
(SWT1) UL 1449 Type 1 and Sine Wave Tracking Module (not applicable for Delta or HRG) 750.00
(ISWT) dIntegral Switch and Sine Wave Tracking Module (not applicable for Delta or HRG) 1488.00
(ISWT1) dUL 1449 Type 1, Integral Switch and Sine Wave Tracking Module (not applicable for Delta or HRG) 1488.00
Accessory Description Cat. No. $ Price
Remote Monitor TVS12RMU 788.00
12-inch Flush Mount Kit TVS12FMK 945.00
20-inch Flush Mount Kit TVS20FMK 1103.00
DE1B Discount
Schedule
www.schneider-electric.us
6SURGE PROTECTIVE DEVICES
© 2012 Schneider Electric
All Rights Reserved 6-3
Surge Protective
Devices
External Surge Protective Device
Refer to Catalog 6671CT9701
External Modular L-L Enhanced SPDs
External modular Line-to-Line (L-L) Enhanced SPDs are parallel systems that provide 10
modes of protection and enhanced, discrete L-L suppression paths.
e208Y/120 series also applies to the following voltage 220Y/127.
f480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240.
External Brick Assembly SPDs
External Brick Assembly (EBA) SPD products consist of a consolidation of phase modules into
one solid brick casting and offered at a competitive price for those who want superior surge
suppression on a limited budget.
a208Y/120 series also applies to the following voltage 220Y/127.
bCan be used on 4-wire or 3-wire grounded neutral system.
c480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240.
External Modular L-L Enhanced SPD
with Sine Wave Tracking Module
Table 6.2: L-L Enhanced SPDs
Service
Vol tage
Peak Surge
Current Rating
per Phase (kA)
NEMA 3R
Cat. No. $ Price
NEMA 4X
Stainless Steel
Cat. No.
$ Price
208Y/120 V, 3-phase,
4-wire + ground e
Wye
120 TVS2MEMA12A( ) 8810.00 TVS2MEMA12S( ) 10010.00
180 TVS2MEMA18A( ) 10790.00 TVS2MEMA18S( ) 12657.00
270 TVS2MEMA27A( ) 13760.00 TVS2MEMA27S( ) 15627.00
360 TVS2MEMA36A( ) 16730.00 TVS2MEMA36S( ) 18597.00
480Y/277 V, 3-phase,
4-wire + ground f
Wye
120 TVS4MEMA12A( ) 9023.00 TVS4MEMA12S( ) 10890.00
180 TVS4MEMA18A( ) 11003.00 TVS4MEMA18S( ) 12870.00
270 TVS4MEMA27A( ) 13973.000 TVS4MEMA27S( ) 15840.00
360 TVS4MEMA36A( ) 16943.00 TVS4MEMA36S( ) 18810.00
External Modular L-L Enhanced Options ( ) $ Price
(1) UL 1449 Type 1 0.00
(SWT) Sine Wave Tracking Module 750.00
(SWT1) UL 1449 Type 1 and Sine Wave Tracking Module 750.00
Accessory Description Cat. No. $ Price
Remote Monitor TVS12RMU 788.00
20-inch Flush Mount Kit TVS20FMK 1103.00
External Brick Assembly SPD
with Integral Switch
Table 6.3: EBA SPDs
Service
Vol tage
Peak Surge
Current Rating
per Phase (kA)
NEMA 3R
Cat. No. $ Price
NEMA 4X
Stainless Steel
Cat. No.
$ Price
120/240 V,1-phase,
3-wire + ground
Wye
120 TVS1EBA12A( ) 3467.00 TVS1EBA12S( ) 4884.00
160 TVS1EBA16A( ) 4208.00 TVS1EBA16S( ) 5625.00
240 TVS1EBA24A( ) 6290.00 TVS1EBA24S( ) 7707.00
208Y/120 V, 3-phase,
4-wire + ground ab
Wye
120 TVS2EBA12A( ) 3588.00 TVS2EBA12S( ) 5006.00
160 TVS2EBA16A( ) 4388.00 TVS2EBA16S( ) 5805.00
240 TVS2EBA24A( ) 6525.00 TVS2EBA24S( ) 7943.00
240/120 V, 3-phase,
4-wire + ground
High-leg Delta
120 TVS3EBA12A( ) 3588.00 TVS3EBA12S( ) 5006.00
160 TVS3EBA16A( ) 4388.00 TVS3EBA16S( ) 5805.00
240 TVS3EBA24A( ) 6525.00 TVS3EBA24S( ) 7943.00
480Y/277 V, 3-phase,
4-wire + ground bc
Wye
120 TVS4EBA12A( ) 3743.00 TVS4EBA12S( ) 5160.00
160 TVS4EBA16A( ) 4581.00 TVS4EBA16S( ) 5999.00
240 TVS4EBA24A( ) 6827.00 TVS4EBA24S( ) 8244.00
600Y/347 V, 3-phase,
4-wire + ground b
Wye
120 TVS8EBA12A( ) 3905.00 TVS8EBA12S( ) 5322.00
160 TVS8EBA16A( ) 4787.00 TVS8EBA16S( ) 6204.00
240 TVS8EBA24A( ) 7143.00 TVS8EBA24S( ) 8561.00
External Brick Assembly Options ( ) $ Price
(1) UL 1449 Type 1 0.00
(I) Integral Switch 738.00
(SWT) Sine Wave Tracking Module (not applicable for Delta) 750.00
(I1) UL 1449 Type 1 and Integral Switch 738.00
(SWT1) UL 1449 Type 1 and Sine Wave Tracking Module (not applicable for Delta) 750.00
(ISWT) Integral Switch and Sine Wave Tracking Module (not applicable for Delta) 1,488.00
(ISWT1) UL 1449 Type 1, Integral Switch and Sine Wave Tracking Module (not applicable for Delta) 1,488.00
Accessory Description Cat. No. $ Price
Remote Monitor TVS12RMU 788.00
12-inch Flush Mount Kit TVS12FMK 945.00
20-inch Flush Mount Kit TVS20FMK 1103.00
PE4 PE7 PE1A Discount
Schedule
www.schneider-electric.us
6SURGE PROTECTIVE DEVICES
6-4 © 2012 Schneider Electric
All Rights Reserved
Surge Protective
Devices
Replacement Modules
Refer to Catalog 6671CT9701
a208Y/120 series also applies to the following voltage 220Y/127.
bHigh-leg delta (Phase B modules are different than Phase A and Phase C modules).
c480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240.
a208Y/120 series also applies to the following voltage 220Y/127.
bHigh-leg delta (Phase B modules are different than Phase A and Phase C modules).
c480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240.
a208Y/120 series also applies to the following voltage 220Y/127.
b480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240.
a208Y/120 series also applies to the following voltage 220Y/127.
b480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240.
Replacement Modules
All modules and brick assemblies are US and
Canadian UL® Recognized to UL 1449 3rd
Edition and UL 1283 5th Edition.
Complies with requirements of NEC® Article 285
and CSA C22.2 No. 8-M1986 as appropriate.
dFor UL 1449 Type 1 Modules, add suffix (1).
Example: MA1IMA121
Table 6.4: EMA Replacement Modules
System
Volt ag e
Peak Surge
Current Rating (kA)
Catalog Numbers
Phase A $ Price Phase B $ Price Phase C $ Price
120/240 V, 1-phase,
3-wire + ground
120 MA1IMA12 906.00 ——MA1IMA12 906.00
160 MA1IMA16 1064.00 ——MA1IMA16 1064.00
240 MA1IMA24 1229.00 ——MA1IMA24 1229.00
208Y/120 V, 3-phase,
4-wire + ground a
Wye
120 MA1IMA12 906.00 MA1IMA12 906.00 MA1IMA12 906.00
160 MA1IMA16 1064.00 MA1IMA16 1064.00 MA1IMA16 1064.00
240 MA1IMA24 1229.00 MA1IMA24 1229.00 MA1IMA24 1229.00
120/240 V, 3-phase,
4-wire + ground b
High-Leg Delta
120 MA1IMA12 906.00 MA3IMA12 906.00 MA1IMA12 906.00
160 MA1IMA16 1064.00 MA3IMA16 1064.00 MA1IMA16 1064.00
240 MA1IMA24 1229.00 MA3IMA24 1229.00 MA1IMA24 1229.00
240 V, 3-phase,
3-wire + ground
Delta
120 MA6IMA12 906.00 MA6IMA12 906.00 MA6IMA12 906.00
160 MA6IMA16 1064.00 MA6IMA16 1064.00 MA6IMA16 1064.00
240 MA6IMA24 1229.00 MA6IMA24 1229.00 MA6IMA24 1229.00
480Y/277 V, 3-phase,
4-wire + ground c
Wye
120 MA4IMA12 906.00 MA4IMA12 906.00 MA4IMA12 906.00
160 MA4IMA16 1064.00 MA4IMA16 1064.00 MA4IMA16 1064.00
240 MA4IMA24 1229.00 MA4IMA24 1229.00 MA4IMA24 1229.00
480Y/277 V, 3-phase,
3-wire + ground c
High-Resistance Ground
120 MA4IMA12H 906.00 MA4IMA12H 906.00 MA4IMA12H 906.00
160 MA4IMA16H 1064.00 MA4IMA16H 1064.00 MA4IMA16H 1064.00
240 MA4IMA24H 1229.00 MA4IMA24H 1229.00 MA4IMA24H 1229.00
480 V, 3-phase,
3-wire + ground
Delta
120 MA5IMA12 906.00 MA5IMA12 906.00 MA5IMA12 906.00
160 MA5IMA16 1064.00 MA5IMA16 1064.00 MA5IMA16 1064.00
240 MA5IMA24 1229.00 MA5IMA24 1229.00 MA5IMA24 1229.00
600Y/347 V, 3-phase,
4-wire + ground
Wye
120 MA8IMA12 906.00 MA8IMA12 906.00 MA8IMA12 906.00
160 MA8IMA16 1064.00 MA8IMA16 1064.00 MA8IMA16 1064.00
240 MA8IMA24 1229.00 MA8IMA24 1229.00 MA8IMA24 1229.00
600Y/347 V, 3-phase,
3-wire + ground
High-Resistance Ground
120 MA8IMA12H 906.00 MA8IMA12H 906.00 MA8IMA12H 906.00
160 MA8IMA16H 1064.00 MA8IMA16H 1064.00 MA8IMA16H 1064.00
180 MA8IMA18H 1229.00 MA8IMA18H 1229.00 MA8IMA18H 1229.00
600 V, 3-phase,
3-wire + ground
Delta
120 MA9IMA12 906.00 MA9IMA12 906.00 MA9IMA12 906.00
160 MA9IMA16 1064.00 MA9IMA16 1064.00 MA9IMA16 1064.00
180 MA9IMA18 1229.00 MA9IMA18 1229.00 MA9IMA18 1229.00
Table 6.5: EBA Replacement Modules
System Voltage Peak Surge
Current Rating (kA) Catalog Numbers $ Price
120/240 V, 1-phase,
3-wire + ground
120 MA1IBA12 2717.00
160 MA1IBA16 3189.00
240 MA1IBA24 3686.00
208Y/120 V, 3-phase,
4-wire + ground a
120 MA2IBA12 2717.00
160 MA2IBA16 3189.00
240 MA2IBA24 3686.00
240/120 V, 3-phase,
4-wire + ground b
High-leg Delta
120 MA3IBA12 2717.00
160 MA3IBA16 3189.00
240 MA3IBA24 3686.00
480Y/277 V, 3-phase,
4-wire + ground c
Wye
120 MA4IBA12 2717.00
160 MA4IBA16 3189.00
240 MA4IBA24 3686.00
600Y/347 V, 3-phase,
4-wire + ground
Wye
120 MA8IBA12 2717.00
160 MA8IBA16 3189.00
240 MA8IBA24 3686.00
Table 6.6: L-L Enhanced MA (L-N, L-G) Replacement Modules
System
Volt ag e
Peak Surge
Current Rating (kA)
Catalog Numbers
Phase A $ Price Phase B $ Price Phase C $ Price
208Y/120 V, 3-phase,
4-wire + ground a
Wye
120 MA1IMA12 906.00 MA1IMA12 906.00 MA1IMA12 906.00
180 MA1IMA16 1064.00 MA1IMA16 1064.00 MA1IMA16 1064.00
270 MA1IMA16 1064.00 MA1IMA16 1064.00 MA1IMA16 1064.00
360 MA1IMA24 1229.00 MA1IMA24 1229.00 MA1IMA24 1229.00
480Y/277 V, 3-phase,
4-wire + ground b
Wye
120 MA4IMA12 906.00 MA4IMA12 906.00 MA4IMA12 906.00
180 MA4IMA16 1064.00 MA4IMA16 1064.00 MA4IMA16 1064.00
270 MA4IMA16 1064.00 MA4IMA16 1064.00 MA4IMA16 1064.00
360 MA4IMA24 1229.00 MA4IMA24 1229.00 MA4IMA24 1229.00
Table 6.7: L-L Enhanced (L-L) Replacement Modules
System
Voltage
Peak Surge
Current Rating (kA)
Catalog Numbers
Phase A $ Price Phase B $ Price Phase C $ Price
208Y/120 V, 3-phase,
4-wire + ground a
Wye
120 MA2IMA40LL 604.00 MA2IMA40LL 604.00 MA2IMA40LL 604.00
180 MA2IMA60LL 709.00 MA2IMA60LL 709.00 MA2IMA60LL 709.00
270 MA2IMA90LL 819.00 MA2IMA90LL 819.00 MA2IMA90LL 819.00
360 MA2IMA12LL 946.00 MA2IMA12LL 946.00 MA2IMA12LL 946.00
480Y/277 V, 3-phase,
4-wire + ground b
Wye
120 MA4IMA40LL 604.00 MA4IMA40LL 604.00 MA4IMA40LL 604.00
180 MA4IMA60LL 709.00 MA4IMA60LL 709.00 MA4IMA60LL 709.00
270 MA4IMA90LL 819.00 MA4IMA90LL 819.00 MA4IMA90LL 819.00
360 MA4IMA12LL 946.00 MA4IMA12LL 946.00 MA4IMA12LL 946.00
HRG Replacement
Module
Delta Replacement
Module
MA Replacement
Module
MA Replacement
Module
L-L Enhanced
Replacement Module
PE4 PE7 PE1A Discount
Schedule
www.schneider-electric.us
6SURGE PROTECTIVE DEVICES
© 2012 Schneider Electric
All Rights Reserved 6-5
Surge Protective
Devices
Internally Mounted Surge Protective Devices
Refer to Catalog 6671CT9701
Internally Mounted—Retrofit
To ensure high-performance surge suppression at critical power locations, a variety of Surgelogic™ products have
been designed specifically for retrofitting into commonly used Square D™ systems. The QMB fusible switch, 6 in. MCC
bucket, I-Line and Busway plug-on units come with the SPD factory-installed. Retrofitting SPD units into I-Line, QMB,
MCC, and Busway applications is simple.
Audible alarm with enable/disable switch, dry contacts, and surge counter standard.
200 kA SCCR
Indicator LEDs
EMI/RFI filtering
Internally Mounted Surge Protective Devices
Internally mounted surge protective devices are installed integrally to systems for service entrance and branch panel surge suppression. Internally
mounted SPDs installed next to supply busses provide maximum performance inside Square D™ systems. Built-in performance is the best way to
ensure cost effective power quality (especially important for critical power facilities).
US and Canadian UL® Recognized as a Type 2 (or 1 with optional suffix in catalog number) SPD Component Assembly to UL 1449 3rd Edition
and UL 1283 5th Edition. Complies with requirements of NEC® Article 285 and CSA C22.2 No. 8-M1986 as appropriate. Complies with UL 96A
12th Edition Master Label requirements for Lightning Protection Systems.
Internally Mounted—New Construction
Factory installed integral/internal Surgelogic™ SPD products make adding surge suppression to new construction projects easy. Refer to the
sections listed below to identify the correct product for your application or contact Surgelogic™ TAG at 1-800-577-7353 for assistance.
NF NQ PZ4 QED MCC IPAC2
Panelboards
Refer to Section 9
Switchboards and Switchgear
Refer to Section 11
Motor Control
Centers
Refer to Section 17
Integrated Power and
Control Centers
Refer to Section 10
Busway—Refer to Section 12
Table 6.8: Internally Mounted—Retrofit
Vol tage
Surge
Current
Rating
I-Line Branch Units aQMB Branch Units bBusway Units Model 6 MCC Units c
Cat. No. $ Price Cat. No. $ Price Cat. No. $ Price Cat. No. $ PriceeCat. No. $ Priced
120/240 V, 1-phase,
3-wire + ground
120 kA HL1IMA12C( ) 9518.00 FI1IMA12C( ) 10185.00 QMB1IMA12 6663.00 ——— —
160 kA HL1IMA16C( ) 10455.00 FI1IMA16C( ) 11199.00 QMB1IMA16 7340.00 ——— —
240 kA HL1IMA24C( ) 14100.00 FI1IMA24C( ) 15525.00 QMB1IMA24 10055.00 ——— —
208Y/120 V, 3-phase,
4-wire + ground fg
Wye
120 kA HL2IMA12C( ) 9893.00 FI2IMA12C( ) 10562.00 QMB2IMA12 6899.00 ——MCC2IMA12 6700.00
160 kA HL2IMA16C( ) 10872.00 FI2IMA16C( ) 11616.00 QMB2IMA16 7602.00 PIU2IMA16 4472.00 MCC2IMA16 8700.00
240 kA HL2IMA24C( ) 15423.00 FI2IMA24C( ) 16170.00 QMB2IMA24 10460.00 PIU2IMA24 6407.00 MCC2IMA24 12200.00
240/120 V, 3-phase,
4-wire + ground
High-leg Delta
120 kA HL3IMA12C( ) 9893.00 FI3IMA12C( ) 10562.00 QMB3IMA12 6899.00 ——MCC3IMA12 6700.00
160 kA HL3IMA16C( ) 10872.00 FI3IMA16C( ) 11616.00 QMB3IMA16 7602.00 PIU3IMA16 4472.00 MCC3IMA16 8700.00
240 kA HL3IMA24C( ) 15423.00 FI3IMA24C( ) 16170.00 QMB3IMA24 10460.00 PIU3IMA24 6407.00 MCC3IMA24 12200.00
240 V, 3-phase,
3-wire + ground,
Delta
120 kA HL6IMA12C( ) 9893.00 FI6IMA12C( ) 10562.00 ——— —
160 kA HL6IMA16C( ) 10872.00 FI6IMA16C( ) 11616.00 ——— —
240 kA HL6IMA24C( ) 15423.00 FI6IMA24C( ) 16170.00 ——— —
480Y/277 V, 3-phase,
4-wire + ground fh
Wye
120 kA HL4IMA12C( ) 10271.00 FI4IMA12C( ) 10944.00 QMB4IMA12 7137.00 ——MCC4IMA12 7200.00
160 kA HL4IMA16C( ) 11292.00 FI4IMA16C( ) 12039.00 QMB4IMA16 7868.00 PIU4IMA16 4740.00 MCC4IMA16 9200.00
240 kA HL4IMA24C( ) 16070.00 FI4IMA24C( ) 16818.00 QMB4IMA24 10868.00 PIU4IMA24 6792.00 MCC4IMA24 13200.00
480Y/277 V, 3-phase,
3-wire + ground h
High-Resistance Ground
120 kA HL4HIMA12C( ) 10271.00 FI4HIMA12C( ) 10944.00 ——— —
160 kA HL4HIMA16C( ) 11292.00 FI4HIMA16C( ) 12039.00 ——— —
240 kA HL4HIMA24C( ) 16070.00 FI4HIMA24C( ) 16818.00 ——— —
480 V, 3-phase,
3-wire + ground,
Delta
120 kA HL5IMA12C( ) 10271.00 FI5IMA12C( ) 10944.00 ——— —
160 kA HL5IMA16C( ) 11292.00 FI5IMA16C( ) 12039.00 ——— —
240 kA HL5IMA24C( ) 16070.00 FI5IMA24C( ) 16818.00 ——— —
600Y/347 V, 3-phase,
4-wire + ground f
Wye
120 kA FI8IMA12C( ) 11342.00 QMB8IMA12 7388.00 ——MCC8IMA12 7700.00
160 kA FI8IMA16C( ) 12482.00 QMB8IMA16 8145.00 PIU8IMA16 4919.00 MCC8IMA16 9700.00
240 kA FI8IMA24C( ) 16692.00 QMB8IMA24 11295.00 PIU8IMA24 7048.00 MCC8IMA24 14200.00
600Y/347 V, 3-phase,
3-wire + ground,
High-Resistance Ground
120 kA FI8HIMA12C( ) 11342.00 ——— —
160 kA FI8HIMA16C( ) 12482.00 ——— —
180 kA FI8HIMA18C( ) 16692.00 ——— —
600V, 3-phase,
3-wire + ground,
Delta
120 kA FI9IMA12C( ) 11342.00 ——— —
160 kA FI9IMA16C( ) 12482.00 ——— —
180 kA FI9IMA18C( ) 16692.00 ——— —
aRequires 13.5-inch mounting height.
bRequires 9-inch mounting height.
cRequires 6-inch mounting height.
dPE4 Discount Schedule.
ePE7 Discount Schedule.
fCan be used on 4-wire or 3-wire grounded
neutral system.
g208Y/120 series also applies to the following
voltage 220Y/127.
h480Y/277 series applies to the following voltages
380Y/220, 400Y/230, and 415Y/240.
( ) For a Type 1 SPD, add a “1” suffix to the catalog number.
I-Line™ Surgelogic™
SPD Unit
QMB Surgelogic™
SPD Unit
MCC Surgelogic™
SPD Unit
Busway Surgelogic™
SPD Unit
PE4 PE7 PE1A Discount
Schedule
www.schneider-electric.us
6-6 © 2012 Schneider Electric
All Rights Reserved
6SURGE PROTECTIVE DEVICES
Surge Protective
Devices
Surgelogic™ Surge Protective Devices
Refer to Catalog 6671CT9701
OEM/Assembler Kits
Surgelogic™ OEM/assembler kits allow manufacturers to add industry-leading surge
suppression directly to customized equipment. Manufacturers benefit from shorter wire
lengths that optimize the clamping voltage of the SPD. Products come with a backplane-
mounted SPD, mounting hardware and diagnostic display with 36-inch cables. Audible
alarm, silence switch, remote monitoring contacts, and surge counter are standard.
Available as UL 1449 Type 2 (or 1 with optional suffix in catalog number).
US and Canadian UL® Recognized to UL 1449 3rd Edition and UL 1283 5th Edition.
Complies with requirements of NEC® Article 285 and CSA 22.2 No. 8-M1986 as
appropriate. Complies with UL 96A 12th Edition Master Label requirements for Lightning
Protection Systems.
( ) For a Type 1 SPD, add a “1” suffix to the catalog number.
aNote the last character of the catalog number is the letter “O”, not a zero.
bCan be used on 4-wire or 3-wire grounded neutral system.
c208Y/120 series also applies to the following voltage 220Y/127.
d480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240.
SDSA3650 Surge Protective Devices
SDSA3650 SPDs are designed and listed for indoor or outdoor installation and surge
suppression for three-phase grounded electrical services up to 600 Vac, including delta
services (SDSA3650D). The SDSA3650 series is used extensively in service entrance
panels to provide an efficient and economical means of surge suppression.
US and Canadian UL® Listed as a Type 1 SPD to UL 1449 3rd Edition. Complies with
requirements of NEC® Article 285, CSA 233.1-87, and CSA C22.2 No. 8-M1986 as
appropriate.
LEDs indicate operational status
Short circuit current rating 200 kA
Suitable for indoor and outdoor applications (NEMA Type 4X rated)
Convenient back-nipple mounting
eDo not use on ungrounded systems. Systems must be solidly grounded.
fSee Table 6.13 for QOSAMK mounting kit for installation in QO™ load centers.
OEM Kit
Table 6.9: OEM/Assembler Kits
Service
Volt ag e
Peak Surge Current Rating
per Phase (kA) Cat. No. a$ Price
120/240 V, 1-phase,
3-wire + ground
120 TVS1IMA12O( ) 4137.00
160 TVS1IMA16O( ) 4547.00
240 TVS1IMA24O( ) 6753.00
208Y/120 V, 3-phase,
4-wire + ground bc
Wye
120 TVS2IMA12O( ) 4331.00
160 TVS2IMA16O( ) 4760.00
240 TVS2IMA24O( ) 7082.00
240/120 V, 3-phase,
4-wire + ground
High-leg Delta
120 TVS3IMA12O( ) 4331.00
160 TVS3IMA16O( ) 4760.00
240 TVS3IMA24O( ) 7082.00
240 V, 3-phase,
3-wire + ground bd
Delta
120 TVS6IMA12O( ) 4331.00
160 TVS6IMA16O( ) 4760.00
240 TVS6IMA24O( ) 7082.00
480Y/277 V, 3-phase,
4-wire + ground bd
Wye
120 TVS4IMA12O( ) 4526.00
160 TVS4IMA16O( ) 4976.00
240 TVS4IMA24O( ) 7413.00
480Y/277 V, 3-phase,
3-wire + ground bd
High-Resistance Ground
120 TVS4HIMA12O( ) 4526.00
160 TVS4HIMA16O( ) 4976.00
240 TVS4HIMA24O( ) 7413.00
480 V, 3-phase,
3-wire + ground
Delta
120 TVS5IMA12O( ) 4526.00
160 TVS5IMA16O( ) 4976.00
240 TVS5IMA24O( ) 7413.00
600Y/347 V, 3-phase,
4-wire + ground b
Wye
120 TVS8IMA12O( ) 4751.00
160 TVS8IMA16O( ) 5199.00
240 TVS8IMA24O( ) 7760.00
600Y/347 V, 3-phase,
3-wire + ground b
High Resistance Ground
120 TVS8HIMA12O( ) 4751.00
160 TVS8HIMA16O( ) 5199.00
180 TVS8HIMA18O( ) 7760.00
600 V, 3-phase,
3-wire + ground
Delta
120 TVS9IMA12O( ) 4751.00
160 TVS9IMA16O( ) 5199.00
180 TVS9IMA18O( ) 7760.00
Nipple-Mounted Surge Protective Devices
Table 6.10: SDSA3650 Surge Protective Devices
Description Peak Surge Current Rating
per Phase (kA) Cat. No. $ Price
600 Vac Maximum,
3-phase, 4-wiree40 SDSA3650 f248.00
600 Vac Maximum,
3-phase, 3-wire
Delta
40 SDSA3650D f248.00
SDSA3650
SDSA3650D
OE1A Discount
Schedule
www.schneider-electric.us
6SURGE PROTECTIVE DEVICES
© 2012 Schneider Electric
All Rights Reserved 6-7
Surge Protective
Devices
Nipple Mounted SPDs
Class 6671 / Refer to Catalog 6671CT9701
HWA Surge Protective Devices
Surgelogic™ HWA surge protective devices are compact, nipple-mounted parallel-connected
surge suppressors that come in a variety of voltage configurations, including Delta. A surge
suppression path is provided for each mode, and the product is rated NEMA Type 4X. Internal
diagnostics continuously monitor the device status.
US and Canadian UL® Listed as a Type 2 SPD to UL 1449 3rd Edition and UL 1283 5th
Edition. Complies with requirements of NEC® Article 285 and CSA C22.2 No. 8-M1986 as
appropriate. Complies with UL 96A 12th Edition Master Label requirements for Lightning
Protection Systems.
aCan be used on 4-wire or 3-wire grounded neutral system.
b208Y/120 series also applies to the following voltage 220Y/127.
c480Y/277 series applies to the following voltages 380Y/220, 400Y/230, and 415Y/240.
SDSA1175 Surge Protective Devices
SDSA1175 SPDs are designed and listed for indoor or outdoor installation and surge
suppression for single-phase three-wire 120/240 Vac or two-wire 120 Vac 60 Hz electrical
services. This product is ideal for panel builders as well as manufacturers and integrators of
instrumentation cabinets for industrial, commercial, and residential applications for single-
phase power systems. Two SDSA1175 surge protection devices can be installed to provide
suppression for 208Y/120 Vac three-phase four-wire services.
US and Canadian UL® Listed as Type 1 SPD to UL 1449 3rd Edition. Complies with requirements
of NEC® Article 285, CSA 233.1-87, and CSA C22.2 No. 8-M1986 as appropriate.
LED indicates operational status
Short circuit current rating 25 kA
Suitable for indoor and outdoor applications (NEMA Type 4X rated)
Convenient back-nipple mounting
aSee Table 6.13 for QOSAMK mounting kit for installation in QO™ load centers.
Mounting Brackets and Flush Mount Kits
The nipple products shown in this catalog provide a convenient means of incorporating surge
suppression within a new or existing cabinet. The mounting bracket and flush-mount kits are
designed for easy mounting of nipple products.
LEDs indicate operational status
Short circuit current rating 200 kA
Suitable for indoor and outdoor applications
(NEMA Type 4X rated)
Convenient side-nipple mounting
Compact design provides easy mounting inside
or outside the equipment cabinets
-54 dB EMI/RFI filtering
Sine wave tracking
Audible alarm indicates loss of suppression
(does not contain alarm enable/disable switch)
Dry contacts
Optional flush-mount kit TVSHWAFMK
Table 6.11: HWA Surge Protective Devices
Service
Voltag e
Peak Surge Current Rating
per Phase (kA)
NEMA 4X
Cat. No. $ Price
120/240 V, 1-phase,
3-wire + ground
50 TVS1HWA50X 2385.00
80 TVS1HWA80X 2660.00
100 TVS1HWA10X 3401.00
208Y/120 V, 3-phase,
4-wire + ground ab
50 TVS2HWA50X 2544.00
80 TVS2HWA80X 2810.00
100 TVS2HWA10X 3611.00
240/120 V, 3-phase,
4-wire + ground
High-leg Delta
50 TVS3HWA50X 2544.00
80 TVS3HWA80X 2810.00
100 TVS3HWA10X 3611.00
240 V, 3-phase,
3-wire + ground
Delta
50 TVS6HWA50X 2583.00
80 TVS6HWA80X 2924.00
100 TVS6HWA10X 3606.00
480Y/277 V, 3-phase,
4-wire + ground ac
50 TVS4HWA50X 2640.00
80 TVS4HWA80X 2907.00
100 TVS4HWA10X 3853.00
480 V, 3-phase,
3-wire + ground
Delta
50 TVS5HWA50X 3052.00
80 TVS5HWA80X 3393.00
100 TVS5HWA10X 4075.00
600Y/347 V, 3-phase,
4-wire + ground
50 TVS8HWA50X 2915.00
80 TVS8HWA80X 3171.00
100 TVS8HWA10X 3853.00
600 V, 3-phase,
3-wire + ground
Delta
50 TVS9HWA50X 3052.00
80 TVS9HWA80X 3393.00
100 TVS9HWA10X 4075.00
Table 6.12: SDSA1175 Surge Protective Devices
System Voltage Peak Surge Current Rating
per Phase (kA) Cat. No. $ Price
120/240 V, 1-phase, 3-wire 36 SDSA1175 a92.00
120 V, 1-phase, 2-wire 36 SDSA1175T a92.00
Table 6.13: Mounting Bracket for Enclosures
Description Cat. No. $ Price
Mounting bracket for QO™ and Homeline™ load centers and other enclosures QOSAMK 11.40
Flush-mount kit for XR SPDs TVSXRFMK 58.00
Flush-mount kif for HWA SPDs TVSHWAFMK 180.00
HWA Series
SDSA1175
QOSAMK
DE1B Discount
Schedule
www.schneider-electric.us
6SURGE PROTECTIVE DEVICES
6-8 © 2012 Schneider Electric
All Rights Reserved
Surge Protective
Devices
Residential SPDs
Class 6671 Refer to Catalog 6671CT9701
XR Surge Protective Devices
The XR SPD provides high-quality surge suppression in a compact and versatile package.
This product is ideal for panel builders as well as manufacturers and integrators of
instrumentation cabinets for industrial, commercial, and residential applications for single-
phase power systems.
US and Canadian UL® Listed as Type 1 SPD to UL 1449 3rd Edition. Complies with
requirements of NEC® Article 285, CSA 233.1-87, and CSA C22.2 No. 8-M1986 as
appropriate.
Whole House Surge Protective Devices
Whole House devices are designed to deliver surge suppression that addresses the entire
home. AC modules are connected to the circuit breaker load center and provide
suppression for all equipment connected to the power system. Whole House systems
incorporate AC modules as well as modules for other metallic lines coming into the home
including telephone/DSL and coaxial video/data.
US and Canadian UL® Listed as Type 2 SPD to UL 1449 3rd Edition. Complies with
requirements of NEC® Article 285, CSA 233.1-87, and CSA C22.2 No. 8-M1986 as appropriate.
Telephone and coaxial video modules US and Canadian UL® Recognized to UL 497A 4th
Edition and UL 497B 4th Edition.
120/240 Vac, 80 kA/phase AC surge suppression
LED status indicators for AC surge suppression
Telephone surge suppression module supports four lines with tool-less Insulation Displacement
Connectors (IDC)
Coaxial surge suppression module supports one line of video/data
Whole House Accessories
Add additional surge suppression or replace existing modules in Whole House products.
Coaxial and telephone modules: US and Canadian UL® Recognized to UL 497A 4th
Edition and UL 497B 4th Edition.
AC Module: US and Canadian UL® Listed as Type 1 SPD to UL 1449 3rd Edition. Complies
with requirements of NEC® Article 285, CSA 233.1-87, and CSA C22.2 No. 8-M1986 as
appropriate.
QO™, NQ, and Homeline™ Load Center Surge Protective Devices
Square D™ load center surge protective devices are easy to install plug-in units that install
as quickly as a standard circuit breaker. The surge suppressors use two pole spaces in a
QO™ or Homeline™ load center, or NQ panelboard.
US and Canadian UL® Listed as Type 2 SPD to UL 1449 3rd Edition. Complies with
requirements of NEC® Article 285, CSA 233.1-87, and CSA C22.2 No. 8-M1986 as appropriate.
LEDs indicate operational status
Short circuit current rating 25 kA
Convenient side nipple mounting
Suitable for indoor and outdoor applications
(NEMA Type 4X rated)
Optional flush mount kit TVSXRFMK
Table 6.14: XR Nipple-Mounted Surge Protective Devices
System Voltage Peak Surge Current Rating
per Phase (kA) Cat. No. $ Price
120/240 V, 1-phase,
3-wire + ground
50 TVS120XR50S 315.00
80 TVS120XR80S 515.00
XR Series
Residential Surge Protective Devices
Table 6.15: Whole House Surge Protective Devices
Description Included Modules Cat. No. $ Price
Whole House NEMA 1 Basic AC SDSB1175CB 439.00
Whole House NEMA 1 AC, Telephone, Coax (1) SDSB1175C 630.00
Whole House NEMA 3R Basic AC SDSB1175RB 546.00
Whole House NEMA 3R AC, Telephone, Coax (1) SDSB1175R 737.00
Home Electronics Protective Device AC HEPD80 185.00
Table 6.16: Accessories
Description Cat. No. $ Price
4-Line telephone surge suppressor with tool-less IDC terminations SDSA4P 101.00
Coaxial video surge suppressor SDSA2V 90.00
Whole House AC Module (HEPD80) replacement kit HEPD80RK 204.00
QO2175SB for QO™ load centers,
combination devices, and NQ panelboards
HOM2175SB for Homeline™ load centers and
combination devices
Plug-on design requires two pole spaces
LED indicates operational status
22.5 kA per phase
Table 6.17: QO™, NQ, and Homeline™ Panelboard Surge Arresters
Description Cat. No. $ Price
QO™ Surgebreaker for QO and NQ QO2175SB 159.00
Homeline™ Surgebreaker HOM2175SB 159.00
SDSB1175C SDSB1175R
HEPD80
SDSA4P
SDSA2V HEPD80RK
QO2175SB HOM2175SB
DE1B Discount
Schedule

Navigation menu