4C

Control Station Covers

4C

Hinged and Open Front

Open Front Cover

Hinged Cover

Applications:

Hinged Covers

Added environmental protection for Eaton's Crouse-Hinds control
stations is now available from a patented "slip on" series of covers.
Easy to install, these enclosures are available in hinged and open
front styles, and are ideal for corrosive and adverse areas where
product endurance is essential.
Secured Access Hinged Cover
• High moisture areas due to weather, steam, or wash down
procedures.
• Areas where dirt, dust, mud, sand, etc. interferes with equipment
operation.
• Prevention of accidental equipment operation.
• Instances requiring equipment lockout/tagout.
Quick Access Open Front Cover
• Areas requiring quick access to control device.
• Areas of high moisture from weather or dripping liquid.
• Prevention of accidental equipment operation.
• Areas with possible damage from bumping or banging.

Single Gang Application
EDS(C) and EFD(C) control stations
EFS(C) control stations
MC(C) control stations
FS(C) back box with cover assembly
FD(C) back box with cover assembly
EGF11 and EGF12 (Ground Fault)
N2S(C) Krydon: 1 & 2 devices
N2D(C) Krydon: 1 & 2 devices
GHG432 control station

Cat. #
NC CH1
NC CH1
NC CH1
NC CH1
NC CH1
NC CH1
NC CH1
NC CH1
NC CH1

Single Gang (Long) Application
EFD(C) (3 device)
N2S(C) Krydon: 3 devices
N2S(C) Krydon: 4 devices

Cat. #
NC CH1 3L
NC CH1 N2S 3L
NC CH1 N2S 4L

Double Gang Application
EDS(C) control stations
EDSCM32: 2 gang tandem
EDSCM33: 3 gang tandem
FS(C) back box with cover
FD(C) back box with cover
EDSC378 - 3 gang tandem assembly

Cat. #
NC CH2
NC CH2L
NC CH3L
NC CH2 FS
NC CH2 FD
NC CH1 MC3

Features and Benefits:
• Clear UV stabilized Lexan polycarbonate plastic allows the enduser to see enclosed controls and is strong enough to withstand
the rough treatment found in the industrial workplace.
• Downtime due to weather or accidental bumping is eliminated and
plant shutdowns caused by inoperable or accidentally operated
pushbutton devices are non-existent.
• Lockout/tagout capabilities conform to OSHA requirements and
provides increased personnel safety.
• Quick and easy slip on installation requires no tools or interruption
of service.
• Hinged cover provides superior sealing through heavy duty
neoprene gaskets.
• Colored covers are available (e.g. red for emergency, yellow for
fire alarm, etc.).
• Specific chemical-resistant covers available (may not be clear) consult factory for minimum order quantity.
• Capability to engineer cover to fit any size device - consult factory.

EFS
MC
FS
FD
EGF 11
N2S
N2D
GHG

Open Front Covers
Single Gang Application
EDS(C) and EFD(C) control stations
EFS(C) control stations
MC(C) control stations
FS(C) back box with cover assembly
FD(C) back box with cover assembly
EGF11 and EGF12 (Ground Fault)
N2S(C) Krydon: 2 device assembly
N2D(C) Krydon: 3 device assembly

Cat. #
NC CH1
NC CH1
NC CH1
NC CH1
NC CH1
NC CH1
NC CH1
NC CH1

Single Gang (Long) Application
EFD(C): 3 device control stations
N2S(C) Krydon: 3 device assembly
N2S(C) Krydon: 4 device assembly

Cat. #
NC CH1 3L QA
NC CH1 N2S 3L QA
NC CH1 N2S 4L QA

Double Gang Application
EDS(C) control stations
EDSCM32: 2 gang tandem
EDSCM 33: 3 gang tandem
FS(C) back box with cover assembly
FD(C) back box with cover assembly

Cat. #
NC CH2 QA
NC CH2L QA
NC CH3L QA
NC CH2 FS QA
NC CH2 FD QA

QA
EFS QA
MC QA
FS QA
FD QA
EGF QA
N2S QA
N2D QA

Custom covers can be supplied but must be accompanied by either a sample of the device to be covered or a copy of a drawing with all
actual measurements of the device to be covered. Covers can also be color-coded. Consult factory.
570

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Author                          : mabe
Create Date                     : 2014:08:21 11:38:25-04:00
Modify Date                     : 2014:08:21 11:38:25-04:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2014:02:06 15:53:04-05:00
Creator Tool                    : PScript5.dll Version 5.2.2
Format                          : application/pdf
Creator                         : mabe
Title                           : nc-control-station-covers.pdf
Document ID                     : uuid:645dd28c-2c47-4019-bf7c-410b3761848d
Instance ID                     : uuid:5e47ac22-8e2a-4f60-9ae6-36e24d8d1ce1
Producer                        : Acrobat Distiller 10.0.0 (Windows)
Page Count                      : 1
EXIF Metadata provided by EXIF.tools

Navigation menu