101235 Catalog 1

101235-Catalog- 1 101235-Catalog-_1 101235-Catalog-_1 783936 Batch2_1 unilog cesco-content

2014-05-16

: Pdf 101235-Catalog 1 101235-Catalog_1 783936 Batch2_1 unilog

Open the PDF directly: View PDF PDF.
Page Count: 500 [warning: Documents this large are best viewed by clicking the View PDF Link!]

Electrical Construction
Products For Standard, Harsh
and Hazardous Locations
Hubbell Electrical Systems
A Division of Hubbell, Inc. (Delaware)
Chalmit • Hawke • Killark • Raco/Bell • Wiegmann
KL-CATALOG-2011 © 2 0 1 1 H u b b e l l E l e c t r i c a l S y s t e m s P r i n t e d i n U . S . A .
3940 M. L. King Dr.
St. Louis, MO 63113
TEL: (314) 531-0460 FAX: (314) 531-7164
www.hubbell-killark.com
Hubbell Canada, Inc.
870 Brock Road South
Pickering, Ontario L1W-1Z8
(905) 839-1139
Hubbell De Mexico
Av. Coyoacan 1051
Col. Del Valle
Mexico, D.F. 03100
001-5255-9151-9999
Established in 1913, Killark has become a global provider
of harsh and hazardous location products. The Killark
range encompasses industrial and explosion proof fittings
engineered to withstand the toughest extremes in climate from the dry and arid Middle East, tropical
Asia to frozen Northern Canada.
Safety and reliability has been the cornerstone of our business for almost a century. Killark is
dedicated to meeting customer needs, with engineering solutions, new product development and
on-time delivery in every phase of the project.
This commitment underpins our proven ability to supply lower cost total system solutions and
savings over the entire lifetime of a project.
Enclosures / OEM Solutions / Controls
At Killark we understand that each of our customers have different needs.
Our committed employees work in combination with our clients engineering
staff to ensure our enclosures meet and sur-
pass their expectations.
Our extensive range of bolted and threaded
enclosures are utilized daily for use with
control, monitoring, detection, and automa-
tion products.
The Killark product portfolio of control products come in both metallic and
non-metallic designs. The size and depth of the control product range
enable us to provide the best solutions to your control problems.
Distribution and Control Equipment
Killark offers solutions to your distribution and control applica-
tions to both North American and IEC Standards. From lighting,
trace heating and power distribution applications to complex
PLC control systems, our applications engineers have a com-
petence to take a project from conceptual to finished goods.
The versatility of our product
range allows us to use multiple
enclosure coupling techniques
to cater to all demands of our
clients.
From single point protection to
rack applications, Killark pro-
vides cost effective solutions
with high quality, reliability and
ease-of-maintenance built in.
i1
i2
Lighting
Killark luminaires are suitable for the extreme environments. Available in
copper-free aluminum, fiberglass reinforced polyester, or stainless steel.
Killark lighting fixtures meet and exceed the requirements for corrosive,
vibration, or explosive atmospheres.
Housing styles include floods, wallpacks, linear
fluorescent, and enclosed/gasketed area lighting
with a range of mounting styles and Killark’s exclu-
sive patented swing-barrel nut attachment system.
Killark’s lighting products encompass the latest in
long life energy and labor saving LED, Induction,
and fluorescent technologies in a variety of hous-
ing types for virtually any application - the range of
Killark lamp sources include:
LED - High output solder-less connected field replaceable boards
QL - 55W to 165W
HID - 35W HPS to 1000W Metal Halide
Fluorescent - Linear and Compact
Signaling - LED and Xenon
Ranging from 20 Amp bladed style to 200 Amp pin & sleeve configu-
rations, Killark provides numerous solutions for safely supplying power
to fixed and portable equipment in hostile environments.
Interchangeability with the other manufacturers
configurations provides user flexibility for real
world applications. The range also has exclusive
features such as breech-lock caps with a “3rd
Hand” notch.
Devices include plugs, receptacles, panel recep-
tacles, and connectors to extend the reach of
portable equipment. For personnel safety, ground
fault protected receptacles, both portable and
fixed, are available.
Plugs and Receptacles
A major factor in all harsh and hazardous environments is the ability to provide
reliable cable terminations and conduit connections.
Iron and Aluminum Fittings for rigid and IMC conduit
raceway systems. Third party certified to NEC, CEC,
ATEX and IEC standards which enables equipment and
installations to be suitable for global applications.
Copper-Free Aluminum Connectors are designed to terminate jacketed interlocked cables (MC),
corrugated continuously welded metal clad cables (MC-HL) and non-armored cables (SO, TC).
Connectors and Fittings
www.killark.com
E
DE
About this catalog
This Killark catalog is organized to help you quickly locate product and application
information. Each product section begins with a contents page that lists all the
items in the section. Tabs are located on the edge of each right hand page. The
Table of Contents is listed below.
New Products in this Catalog . . . . . . . . . . . . . . .i4
NumericIndex ......................N0-N16
Hazardous Location Information . . . . . . . .H1-H17
Fittings.............................Fi-F86
Enclosures..........................Ei-E32
Distribution Equipment . . . . . . . . . . . . . .DEi-DE26
Plugs and Receptacles . . . . . . . . . . . . . .PRi-PR27
Controls ...........................Ci-C59
Lighting ...........................Li-L224
F
PR
C
L
i3
Innovative thinking has made Killark an industry leader.
Killark is known for providing individual client solutions to complex
environmental requirements. Reliable and proven technology,
coupled with value added engineering enables lower total installation
costs with a lifetime of savings.
CO Series
Combination
Bodies
F20
B7EP/Q
Compact
Enclosures
E15
KB Series
Flame Arrestors
F64
B7NFD SERIES
Compact
Disconnect
Switches
DE9
EXBLI/PI
IEC Circuit
Breaker
Panelboards
DE22
UGRP Series
Panel Mount
Receptacles
PR25
UGRC Series
Connectors
PR24
Switchrack
Assemblies
DE26
D2C Series
Non-Metallic
Control Stations
C2
B7MS Series
Compact
IEC / NEMA
Stations
C55
NVPI / F Series
Non-Metallic
Non-Glass
Luminaires
L15
VQ1F / 2F
Compact
Fluorescent
Luminaires
L43
VM1/2 Series
Medium Base
HID Luminaires
L58
MBL Series
Compact LED
Luminaires
L17
VM1L Series
Reduced Profile
LED
Luminaires
L36
NWP Series
Surface Mount
Non-Metallic
Luminaires
L206
VEXA400
Exit Accessory
for EBB / VE4Q
L213
NVS Series
LED
Non-Metallic
Signals
L216
EML Series
Explosion Proof
LED LuminaireL
L132
KF Series
Expanded Options
Elevated
Ambients
Floodlights
L189
DE/VE/VE
Q
Battery Backed
Luminaires
L198
i4
NEW Products in this Catalog
INTRODUCTION
NUMERIC INDEX
N0
170 . . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
270 . . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
370 . . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
470 . . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
570 . . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
670 . . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
870 . . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
970 . . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
4041 . . . . . . . . . . . . . .L190 KF SERIES
6038 . . . . . . . . . . . . . . .E24 GR SERIES
6053 . . . . . . . . . . . . . . .E24 GR SERIES
6058 . . . . . . . . . . . . . . .E24 GR SERIES
6064 . . . . . . . . . . . . . . .E24 GR SERIES
6074 . . . . . . . . . . . . . . .E24 GR SERIES
15515 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
15516 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
15517 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
17596 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
17617 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
17618 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
17619 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
17620 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
17621 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
17622 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
17623 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
17624 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
20567 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
22061 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
0460051B . . . . . . . . . . .C27 X/XCS SERIES
0460414B . . . . . . . . . . .C27 X/XCS SERIES
0735015B . . . . . . . . . . .L96 VM SERIES
15722LABB . . . . . . . . .E29 HK/2HK SERIES
15871AABB . . . . . . . . .L12 V SERIES
170C . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
170CSA . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
170SA . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
17505AAAB ................................L212
180F . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
180S . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
1FA . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
1FAC . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
1FB . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
1FBC . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
1FG . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
1FGC . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
1FR . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
1FRC . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
1FT . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
1FTC . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
270C . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
270CSA . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
270SA . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
280F . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
280S . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
2FA . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2FAC . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2FB . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2FBC . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2FD . . . . . . . . . . . . . . . .F38 2FD SERIES
2FD-1 . . . . . . . . . . . . . .F37 2FD SERIES
2FD-1M . . . . . . . . . . . .F37 2FD SERIES
2FD-2 . . . . . . . . . . . . . .F37 2FD SERIES
2FD-2M . . . . . . . . . . . .F37 2FD SERIES
2FDC-1 . . . . . . . . . . . . .F37 2FD SERIES
2FDC-1M . . . . . . . . . . .F37 2FD SERIES
2FDC-2 . . . . . . . . . . . . .F37 2FD SERIES
2FDC-2M . . . . . . . . . . .F37 2FD SERIES
2FDQ . . . . . . . . . . . . . . .F39 FDQ SERIES
2FG . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2FGC . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2FR . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2FRC . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2FS . . . . . . . . . . . . . . . .F38 2FS SERIES
2FS-1 . . . . . . . . . . . . . .F37 2FS SERIES
2FS-1M . . . . . . . . . . . .F37 2FS SERIES
2FS-2 . . . . . . . . . . . . . .F37 2FS SERIES
2FS-2M . . . . . . . . . . . .F37 2FS SERIES
2FS-3 . . . . . . . . . . . . . .F37 2FS SERIES
2FS-3M . . . . . . . . . . . .F37 2FS SERIES
2FSBC . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
2FSBCM . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
2FSC-1 . . . . . . . . . . . . .F37 2FS SERIES
2FSC-1M . . . . . . . . . . .F37 2FS SERIES
2FSC-2 . . . . . . . . . . . . .F37 2FS SERIES
2FSC-2M . . . . . . . . . . .F37 2FS SERIES
2FSD-1 . . . . . . . . . . . . .F37 2FS SERIES
2FSD-1M . . . . . . . . . . .F37 2FS SERIES
2FSD-2 . . . . . . . . . . . . .F37 2FS SERIES
2FSD-2M . . . . . . . . . . .F37 2FS SERIES
2FSQ . . . . . . . . . . . . . . .F39 FSQ SERIES
2FSRG . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2FST . . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
2FT . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2FTA . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2FTAC . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2FTC . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
2GCBB-13Q . . . . . . . .DE24 GCBB SERIES
2GCBB-15Q1 . . . . . . .DE24 GCBB SERIES
2GCBB-15Q13 . . . . . .DE24 GCBB SERIES
2GCBB-15Q2 . . . . . . .DE24 GCBB SERIES
2GCBB-1Q . . . . . . . . .DE24 GCBB SERIES
2GCBB-1Q . . . . . . . . .DE24 GCBB SERIES
2GCBB-20Q1 . . . . . . .DE24 GCBB SERIES
2GCBB-20Q13 . . . . . .DE24 GCBB SERIES
2GCBB-20Q2 . . . . . . .DE24 GCBB SERIES
2GCBB-2Q . . . . . . . . .DE24 GCBB SERIES
2GCBB-30Q1 . . . . . . .DE24 GCBB SERIES
2GCBB-30Q2 . . . . . . .DE24 GCBB SERIES
2GCBB-40Q1 . . . . . . .DE24 GCBB SERIES
2GCBB-40Q2 . . . . . . .DE24 GCBB SERIES
2GOU . . . . . . . . . . . . . .F56 GE SERIES ACC
2GRB . . . . . . . . . . . . . . .E24 GR SERIES
2GRBD . . . . . . . . . . . . .E24 GR SERIES
2HFX-G4 . . . . . . . . . . .L181 HFX SERIES
2HKB . . . . . . . . . . . . . . .E29 HK/2HK SERIES
2HKB-B-2D . . . . . . . . .E29 HK/2HK SERIES
2HKB-B-2GLD . . . . . . .E29 HK/2HK SERIES
2HKB-B-4D . . . . . . . . .E29 HK/2HK SERIES
2HKB-B-B . . . . . . . . . . .E29 HK/2HK SERIES
2HKB-BC-2DC . . . . . . .E29 HK/2HK SERIES
2HKB-BC-2GLDC . . . .E29 HK/2HK SERIES
2HKB-BC-4DC . . . . . . .E29 HK/2HK SERIES
2HKB-BC-BC . . . . . . . .E29 HK/2HK SERIES
2HKB-BC-GLC . . . . . . .E29 HK/2HK SERIES
2HKB-B-GL . . . . . . . . .E29 HK/2HK SERIES
2KRS-215-120 . . . . . .PR19 KR SERIES
2KRS-215-220 . . . . . .PR19 KR SERIES
2KRS-215-320 . . . . . .PR19 KR SERIES
2KRS-218-120 . . . . . .PR19 KR SERIES
2KRS-218-220 . . . . . .PR19 KR SERIES
2KRS-218-320 . . . . . .PR19 KR SERIES
370C . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
370CSA . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
370SA . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
380F . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
380S . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
3FA . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
3FB . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
3FD . . . . . . . . . . . . . . . .F38 3FD SERIES
3FDQ . . . . . . . . . . . . . . .F39 FDQ SERIES
3FS . . . . . . . . . . . . . . . .F38 3FS SERIES
3FSBC . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
3FSQ . . . . . . . . . . . . . . .F39 FSQ SERIES
3FSRG . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
3FST . . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
3FT . . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
3GCBB-15Q1 . . . . . . .DE24 GCBB SERIES
3GCBB-1Q . . . . . . . . .DE24 GCBB SERIES
3GCBB-20Q1 . . . . . . .DE24 GCBB SERIES
3GCBB-30Q1 . . . . . . .DE24 GCBB SERIES
3GCBB-40Q1 . . . . . . .DE24 GCBB SERIES
3GRM . . . . . . . . . . . . . .E24 GR SERIES
3GRMD . . . . . . . . .F56,E24 GR SERIES
3HFX-G4 . . . . . . . . . . .L181 HFX SERIES
470C . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
470CSA . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
470SA . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
480F . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
480S . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
4FDQ . . . . . . . . . . . . . . .F39 FDQ SERIES
4GCBB-15Q1 . . . . . . .DE24 GCBB SERIES
4GCBB-1Q . . . . . . . . .DE24 GCBB SERIES
4GCBB-20Q1 . . . . . . .DE24 GCBB SERIES
4GCBB-30Q1 . . . . . . .DE24 GCBB SERIES
4GCBB-40Q1 . . . . . . .DE24 GCBB SERIES
4GOU . . . . . . . . . . . . . .F56 GE SERIES ACC
4GRB . . . . . . . . . . . . . . .E24 GR SERIES
4GRBD . . . . . . . . . . . . .E24 GR SERIES
4GRH . . . . . . . . . . . . . .E24 GR SERIES
4GRHA . . . . . . . . . . . . .E24 GR SERIES
4GRHC . . . . . . . . . . . . .E24 GR SERIES
4GRHD . . . . . . . . . . . . .E24 GR SERIES
4GRK . . . . . . . . . . . . . . .E24 GR SERIES
4GRKD . . . . . . . . . . . . .E24 GR SERIES
570C . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
570CSA . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
570SA . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
580F . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
580S . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
5GRM . . . . . . . . . . . . . .E24 GR SERIES
5GRMD . . . . . . . . .F56,E24 GR SERIES
6086PAN . . . . . . . . . . . .E24 GR SERIES
6247-10 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6247-14 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6247-18 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6247-8 . . . . . . . . . . . .E3,17 DB MOUNTING PANS
6248-10 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6248-14 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6249-14 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6249-16 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6249-18 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6249-24 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6250-18 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6250-24 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6250-36 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6251-24 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6251-30 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6252-30 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6252-36 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6307-12 . . . . . . . . . . .E3,17 DB MOUNTING PANS
6307-6 . . . . . . . . . . . .E3,17 DB MOUNTING PANS
670C . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
670CSA . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
670SA . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
680F . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
680S . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
7988-1 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
7988-3 . . . . . . . . . . .E16,17 XJB MOUNTING PANS
7988-4 . . . . . . . .E10,16,17 EXB/XJB MTG PANS
7995-1 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
7995-2 . . . . . . . . . . . . .E17 EXB/XJB/DB MTG PANS
7995-5 . . . . . . . . . . .E16,17 XJB MOUNTING PANS
7996-1 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
7996-2 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
7996-4 . . . . . . . . . . .E16,17 XJB MOUNTING PANS
7996-5 . . . . . . . . . . .E16,17 XJB MOUNTING PANS
7996-6 . . . . . . . . . . .E16,17 XJB MOUNTING PANS
7997-1 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
7997-5 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
7997-6 . . . . . . . . . . .E10,17 EXB MOUNTING PANS
7998-4 . . . . . . . . . . .E16,17 XJB MOUNTING PANS
7998-5 . . . . . . . . . . .E16,17 XJB MOUNTING PANS
7999-1 . . . . . . . . . . . . .E17 EXB/XJB/DB MTG PANS
7999-1 . . . . . . . . . . . . .E17 EXB/XJB/DB MTG PANS
7999-2 . . . . . . . . . . .E16,17 XJB MOUNTING PANS
7999-3 . . . . . . . . . . .E16,17 XJB MOUNTING PANS
8000-1 . . . . . . . .E10,16,17 EXB/XJB MTG PANS
870C . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
870CSA . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
870SA . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
880F . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
880S . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
8GRH . . . . . . . . . . . . . .E24 GR SERIES
8GRHA . . . . . . . . . . . . .E24 GR SERIES
8GRHC . . . . . . . . . . . . .E24 GR SERIES
8GRHD . . . . . . . . . . . . .E24 GR SERIES
970C . . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
970CSA . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
970SA . . . . . . . . . . . . . . .F8 DURALOY 7 SERIES
980F . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
980S . . . . . . . . . . . . . . .F14 DURALOY 8 SERIES
AAK . . . . . . . . . . . . . . .L172 DBF SERIES
ABK . . . . . . . . . . . . . . .L172 DBF SERIES
ADUP-01 . . . . . . . . . . .F65 ADUP SERIES
ADUP-12 . . . . . . . . . . .F65 ADUP SERIES
AFK . . . . . . . . . . . . . . .L172 DBF SERIES
AJAC-4 . . . . . . . . . . . .PR21 KR SERIES
AJAC-5 . . . . . . . . . . . .PR21 KR SERIES
AJAC-6 . . . . . . . . . . . .PR21 KR SERIES
AJAT-4 . . . . . . . . . . . .PR21 KR SERIES
AJAT-5 . . . . . . . . . . . .PR21 KR SERIES
AJC-2 . . . . . . . . . . . . .PR19 KR SERIES
AJC-3 . . . . . . . . . . . . .PR19 KR SERIES
AN-1 . . . . . . . . . . . . . . .F63 AN SERIES
AN-10 . . . . . . . . . . . . . .F63 AN SERIES
AN-11 . . . . . . . . . . . . . .F63 AN SERIES
AN-12 . . . . . . . . . . . . . .F63 AN SERIES
AN-2 . . . . . . . . . . . . . . .F63 AN SERIES
AN-3 . . . . . . . . . . . . . . .F63 AN SERIES
AN-4 . . . . . . . . . . . . . . .F63 AN SERIES
AN-5 . . . . . . . . . . . . . . .F63 AN SERIES
AN-6 . . . . . . . . . . . . . . .F63 AN SERIES
AN-7 . . . . . . . . . . . . . . .F63 AN SERIES
AN-8 . . . . . . . . . . . . . . .F63 AN SERIES
AN-9 . . . . . . . . . . . . . . .F63 AN SERIES
B7011 . . . . . . . . . . . . . .C43 B7 SERIES
B7012 . . . . . . . . . . . . . .C43 B7 SERIES
B7013 . . . . . . . . . . . . . .C43 B7 SERIES
B7014 . . . . . . . . . . . . . .C43 B7 SERIES
B7021 . . . . . . . . . . . . . .C45 B7 SERIES
B7022 . . . . . . . . . . . . . .C45 B7 SERIES
B7023 . . . . . . . . . . . . . .C45 B7 SERIES
B7024 . . . . . . . . . . . . . .C45 B7 SERIES
B7025A2 . . . . . . . . . . .C45 B7 SERIES
B7025A4 . . . . . . . . . . .C45 B7 SERIES
B7025C2 . . . . . . . . . . .C45 B7 SERIES
B7025C4 . . . . . . . . . . .C45 B7 SERIES
B7025G2 . . . . . . . . . . .C45 B7 SERIES
B7025G4 . . . . . . . . . . .C45 B7 SERIES
B7025S2 . . . . . . . . . . .C45 B7 SERIES
B7025S4 . . . . . . . . . . .C45 B7 SERIES
B7025W2 . . . . . . . . . . .C45 B7 SERIES
B7025W4 . . . . . . . . . . .C45 B7 SERIES
B72SS . . . . . . . . . . . . .C48 B7 SERIES
B75CAC . . . . . . . . . . . .C48 B7 SERIES
B75SAC . . . . . . . . . . . .C48 B7 SERIES
B7AD021 . . . . . . . . . . .C46 B7 SERIES
B7AD022 . . . . . . . . . . .C46 B7 SERIES
B7AD023 . . . . . . . . . . .C46 B7 SERIES
B7AD024 . . . . . . . . . . .C46 B7 SERIES
B7AD025K . . . . . . . . . .C46 B7 SERIES
B7APL . . . . . . . . . . . . .C48 B7 SERIES
B7BLA1000 . . . . . . . .DE15 B7L/B7P SERIES
B7BLA1015 . . . . . . . .DE15 B7L/B7P SERIES
B7BLA1020 . . . . . . . .DE15 B7L/B7P SERIES
B7BLA1030 . . . . . . . .DE15 B7L/B7P SERIES
B7BLA1040 . . . . . . . .DE15 B7L/B7P SERIES
B7BLA2000 . . . . . . . .DE15 B7L/B7P SERIES
B7BLA2015 . . . . . . . .DE15 B7L/B7P SERIES
B7BLA2020 . . . . . . . .DE15 B7L/B7P SERIES
B7BLA2030 . . . . . . . .DE15 B7L/B7P SERIES
B7BLA2060 . . . . . . . .DE15 B7L/B7P SERIES
B7BLA2100 . . . . . . . .DE15 B7L/B7P SERIES
B7BLB3000 . . . . . . . .DE15 B7L/B7P SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
B7BLB3015 . . . . . . . .DE15 B7L/B7P SERIES
B7BLB3020 . . . . . . . .DE15 B7L/B7P SERIES
B7BLB3030 . . . . . . . .DE15 B7L/B7P SERIES
B7BLB3060 . . . . . . . .DE15 B7L/B7P SERIES
B7BLC1000 . . . . . . . .DE15 B7L/B7P SERIES
B7BLC1015 . . . . . . . .DE15 B7L/B7P SERIES
B7BLC1020 . . . . . . . .DE15 B7L/B7P SERIES
B7BLC1030 . . . . . . . .DE15 B7L/B7P SERIES
B7BLE1000 . . . . . . . .DE15 B7L/B7P SERIES
B7BLE1020 . . . . . . . .DE15 B7L/B7P SERIES
B7BLE1030 . . . . . . . .DE15 B7L/B7P SERIES
B7BLE2020 . . . . . . . .DE15 B7L/B7P SERIES
B7BLE2030 . . . . . . . .DE15 B7L/B7P SERIES
B7BLE2040 . . . . . . . .DE15 B7L/B7P SERIES
B7BLF2020 . . . . . . . .DE15 B7L/B7P SERIES
B7BPK1000 . . . . . . . .DE15 B7L/B7P SERIES
B7BPK1020 . . . . . . . .DE15 B7L/B7P SERIES
B7BPK2000 . . . . . . . .DE15 B7L/B7P SERIES
B7BPK3000 . . . . . . . .DE15 B7L/B7P SERIES
B7BPK3020 . . . . . . . .DE15 B7L/B7P SERIES
B7BPK3100 . . . . . . . .DE15 B7L/B7P SERIES
B7CA . . . . . . . . . . . . . .DE4 B7C SERIES
B7CB . . . . . . . . . . . . . .DE4 B7C SERIES
B7CC . . . . . . . . . . . . . .DE4 B7C SERIES
B7CD . . . . . . . . . . . . . .DE4 B7C SERIES
B7CE . . . . . . . . . . . . . .DE4 B7C SERIES
B7CF . . . . . . . . . . . . . .DE4 B7C SERIES
B7CT100 . . . . . . . . . . .C48 B7 SERIES
B7CT150 . . . . . . . . . . .C48 B7 SERIES
B7CT200 . . . . . . . . . . .C48 B7 SERIES
B7CT250 . . . . . . . . . . .C48 B7 SERIES
B7CT300 . . . . . . . . . . .C48 B7 SERIES
B7CT50 . . . . . . . . . . . .C48 B7 SERIES
B7CT500 . . . . . . . . . . .C48 B7 SERIES
B7CT75 . . . . . . . . . . . .C47 B7 SERIES
B7DBP . . . . . . . . . . . . .C48 B7 SERIES
B7EA . . . . . . . . . . . . . . .E13 B7E SERIES
B7EAPL . . . . . . . . . . . .C48 B7 SERIES
B7EB . . . . . . . . . . . . . . .E13 B7E SERIES
B7EC . . . . . . . . . . . . . . .E13 B7E SERIES
B7ED . . . . . . . . . . . . . . .E13 B7E SERIES
B7EDBP . . . . . . . . . . . .C48 B7 SERIES
B7EE . . . . . . . . . . . . . . .E13 B7E SERIES
B7EF . . . . . . . . . . . . . . .E13 B7E SERIES
B7EG . . . . . . . . . . . . . . .E13 B7E SERIES
B7EGPL . . . . . . . . . . . .C48 B7 SERIES
B7EH . . . . . . . . . . . . . . .E13 B7E SERIES
B7EJ . . . . . . . . . . . . . . .E13 B7E SERIES
B7EK . . . . . . . . . . . . . . .E13 B7E SERIES
B7EL . . . . . . . . . . . . . . .E13 B7E SERIES
B7ELPBA . . . . . . . . . . .C48 B7 SERIES
B7ELPBG . . . . . . . . . . .C48 B7 SERIES
B7ELPBR . . . . . . . . . . .C48 B7 SERIES
B7EM . . . . . . . . . . . . . .E13 B7E SERIES
B7EN . . . . . . . . . . . . . . .E13 B7E SERIES
B7EP . . . . . . . . . . . . . . .E15 B7EP/B7EQ SERIES
B7EQ . . . . . . . . . . . . . . .E15 B7EP/B7EQ SERIES
B7ERPL . . . . . . . . . . . .C48 B7 SERIES
B7ESS . . . . . . . . . . . . .C48 B7 SERIES
B7ESSHOA . . . . . . . . . .C48 B7 SERIES
B7GPL . . . . . . . . . . . . .C48 B7 SERIES
B7HAC . . . . . . . . . . . . .C48 B7 SERIES
B7IPR . . . . . . . . . . . . . .C48 B7 SERIES
B7L SERIES . . . . .DE12-16 B7L/B7P SERIES
B7LPBA . . . . . . . . . . . .C48 B7 SERIES
B7LPBG . . . . . . . . . . . .C48 B7 SERIES
B7LPBR . . . . . . . . . . . .C48 B7 SERIES
B7MS1P . . . . . . . . . . . .C56 B7MS SERIES
B7MS1PRW . . . . . . . . .C56 B7MS SERIES
B7MS1R . . . . . . . . . . . .C56 B7MS SERIES
B7MS1R . . . . . . . . . . . .C56 B7MS SERIES
B7MS2P . . . . . . . . . . . .C56 B7MS SERIES
B7MS2R . . . . . . . . . . . .C56 B7MS SERIES
B7MS2RA . . . . . . . . . .C56 B7MS SERIES
B7MSN2P . . . . . . . . . .C57 B7MS SERIES
B7NFD1 . . . . . . . . . . . .DE9 B7NFD SERIES
B7NFD13A . . . . . . . . . .DE9 B7NFD SERIES
B7NFD2 . . . . . . . . . . . .DE9 B7NFD SERIES
B7NFD21A . . . . . . . . . .DE9 B7NFD SERIES
B7NFD26A . . . . . . . . . .DE9 B7NFD SERIES
B7P SERIES . . . . . . . . . . . . DE12-16
B7PLR220 . . . . . . . .C38,48 GO SERIES
B7PLR440 . . . . . . . .C38,48 GO SERIES
B7PLR550 . . . . . . . .C38,48 GO SERIES
B7RPL . . . . . . . . . . . . .C48 B7 SERIES
B7SAC . . . . . . . . . . . . .C48 B7 SERIES
B7SH251 . . . . . . . . . . .C48 B7 SERIES
B7SH252 . . . . . . . . . . .C48 B7 SERIES
B7SH254 . . . . . . . . . . .C48 B7 SERIES
B7SH501 . . . . . . . . . . .C48 B7 SERIES
B7SH502 . . . . . . . . . . .C48 B7 SERIES
B7SH504 . . . . . . . . . . .C48 B7 SERIES
B7SSHOA . . . . . . . . . . .C48 B7 SERIES
B7TB . . . . . . . . . . . . . . .C48 B7 SERIES
BKF131830 ..................................L3
BKF263230 ..................................L3
BL-90-1 . . . . . . . . . . . .F66 BL SERIES
BL-90-1M . . . . . . . . . . .F66 BL SERIES
BL-90-2 . . . . . . . . . . . .F66 BL SERIES
BL-90-2M . . . . . . . . . . .F66 BL SERIES
BL-90-3 . . . . . . . . . . . .F66 BL SERIES
BL-90-3M . . . . . . . . . . .F66 BL SERIES
C107 . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C107SA . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C17 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C17SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C18 . . . . . . . . . . . . . . . .F10 DURALOY 8 SERIES
C27 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C27SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C28 . . . . . . . . . . . . . . . .F10 DURALOY 8 SERIES
C37 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C37SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C38 . . . . . . . . . . . . . . . .F10 DURALOY 8 SERIES
C448 . . . . . . . . . . . . . . .F10 DURALOY 8 SERIES
C47 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C47SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C57 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C57SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C58 . . . . . . . . . . . . . . . .F10 DURALOY 8 SERIES
C67 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C67SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C68 . . . . . . . . . . . . . . . .F10 DURALOY 8 SERIES
C77 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C77SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C78 . . . . . . . . . . . . . . . .F10 DURALOY 8 SERIES
C87 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C87SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C88 . . . . . . . . . . . . . . . .F10 DURALOY 8 SERIES
C97 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
C97SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
CBH-114 . . . . . . . . . . . .E21 CBH SERIES
CBH-118 . . . . . . . . . . . .E21 CBH SERIES
CBH-120 . . . . . . . . . . . .E21 CBH SERIES
CBH-12S . . . . . . . . . . .E21 CBH SERIES
CBH-1P . . . . . . . . . . . .E21 CBH SERIES
CBH-20S . . . . . . . . . . .E21 CBH SERIES
CBH-213 . . . . . . . . . . . .E21 CBH SERIES
CBH-216 . . . . . . . . . . . .E21 CBH SERIES
CBH-3P . . . . . . . . . . . .E21 CBH SERIES
CBH-6S . . . . . . . . . . . .E21 CBH SERIES
CBH-8S . . . . . . . . . . . .E21 CBH SERIES
CL-1 . . . . . . . . . . . . . . .F29 CL SERIES
CL-2 . . . . . . . . . . . . . . .F29 CL SERIES
CL-3 . . . . . . . . . . . . . . .F29 CL SERIES
CLM-1 . . . . . . . . . . . . .F29 CL SERIES
CLM-2 . . . . . . . . . . . . .F29 CL SERIES
CLM-3 . . . . . . . . . . . . .F29 CL SERIES
CMCAA050 . . . . . . . . .F83 CMCA SERIES
CMCAB075 . . . . . . . . .F83 CMCA SERIES
CMCAC100 . . . . . . . . .F83 CMCA SERIES
CMCAC2125 . . . . . . . .F83 CMCA SERIES
CMCAD150 . . . . . . . . .F83 CMCA SERIES
CMCAD200 . . . . . . . . .F83 CMCA SERIES
CMCAE250 . . . . . . . . . .F83 CMCA SERIES
CMCAF300 . . . . . . . . . .F83 CMCA SERIES
CMCAH350 . . . . . . . . .F83 CMCA SERIES
CMCXAA050 . . . . . . . .F84 CMCXA SERIES
CMCXAB075 . . . . . . . .F84 CMCXA SERIES
CMCXAC100 . . . . . . . .F84 CMCXA SERIES
CMCXAC2125 . . . . . . .F84 CMCXA SERIES
CMCXAD150 . . . . . . . .F84 CMCXA SERIES
CMCXAD200 . . . . . . . .F84 CMCXA SERIES
CMCXAE250 . . . . . . . .F84 CMCXA SERIES
CMCXAF300 . . . . . . . .F84 CMCXA SERIES
CMCXAH350 . . . . . . . .F84 CMCXA SERIES
COC-1CG . . . . . . . . . . .F20 K-PAK SERIES
COC-2CG . . . . . . . . . . .F20 K-PAK SERIES
COC-3CG . . . . . . . . . . .F20 K-PAK SERIES
COC-4CG . . . . . . . . . . .F20 K-PAK SERIES
COC-5CG . . . . . . . . . . .F20 K-PAK SERIES
COC-6CG . . . . . . . . . . .F20 K-PAK SERIES
COLB-1CG . . . . . . . . . .F20 K-PAK SERIES
COLB-2CG . . . . . . . . . .F20 K-PAK SERIES
COLB-3CG . . . . . . . . . .F20 K-PAK SERIES
COLB-4CG . . . . . . . . . .F20 K-PAK SERIES
COLB-5CG . . . . . . . . . .F20 K-PAK SERIES
COLB-6CG . . . . . . . . . .F20 K-PAK SERIES
COLL-1CG . . . . . . . . . .F21 K-PAK SERIES
COLL-2CG . . . . . . . . . .F21 K-PAK SERIES
COLL-3CG . . . . . . . . . .F21 K-PAK SERIES
COLL-4CG . . . . . . . . . .F21 K-PAK SERIES
COLL-5CG . . . . . . . . . .F21 K-PAK SERIES
COLL-6CG . . . . . . . . . .F21 K-PAK SERIES
COLR-1CG . . . . . . . . . .F21 K-PAK SERIES
COLR-2CG . . . . . . . . . .F21 K-PAK SERIES
COLR-3CG . . . . . . . . . .F21 K-PAK SERIES
COLR-4CG . . . . . . . . . .F21 K-PAK SERIES
COLR-5CG . . . . . . . . . .F21 K-PAK SERIES
COLR-6CG . . . . . . . . . .F21 K-PAK SERIES
COT-1CG . . . . . . . . . . .F22 K-PAK SERIES
COT-2CG . . . . . . . . . . .F22 K-PAK SERIES
COT-3CG . . . . . . . . . . .F22 K-PAK SERIES
COT-4CG . . . . . . . . . . .F22 K-PAK SERIES
COT-5CG . . . . . . . . . . .F22 K-PAK SERIES
COT-6CG . . . . . . . . . . .F22 K-PAK SERIES
CSSERIES................................C9-11
CTCAA050L . . . . . . . . .F82 CTCA SERIES
CTCAB075 . . . . . . . . . .F82 CTCA SERIES
CTCAC100 . . . . . . . . . .F82 CTCA SERIES
CTCAC2125 . . . . . . . . .F82 CTCA SERIES
CTCAD150 . . . . . . . . . .F82 CTCA SERIES
CTCAD200 . . . . . . . . . .F82 CTCA SERIES
CTCAE250 . . . . . . . . . .F82 CTCA SERIES
CTCAF300 . . . . . . . . . .F82 CTCA SERIES
CTCAO050 . . . . . . . . . .F82 CTCA SERIES
CTCAS050S . . . . . . . . .F82 CTCA SERIES
CUP-0 . . . . . . . . . . . . . .F63 CUP SERIES
CUP-1 . . . . . . . . . . . . . .F63 CUP SERIES
CUP-2 . . . . . . . . . . . . . .F63 CUP SERIES
CUP-3 . . . . . . . . . . . . . .F63 CUP SERIES
CUP-375 . . . . . . . . . . . .F63 CUP SERIES
CUP-4 . . . . . . . . . . . . . .F63 CUP SERIES
CUP-5 . . . . . . . . . . . . . .F63 CUP SERIES
CUP-6 . . . . . . . . . . . . . .F63 CUP SERIES
CUP-7 . . . . . . . . . . . . . .F63 CUP SERIES
CUP-8 . . . . . . . . . . . . . .F63 CUP SERIES
CUP-9 . . . . . . . . . . . . . .F63 CUP SERIES
CUPX-0 . . . . . . . . . . . .F63 CUPX SERIES
CUPX-1 . . . . . . . . . . . .F63 CUPX SERIES
CUPX-2 . . . . . . . . . . . .F63 CUPX SERIES
CUPX-250 . . . . . . . . . .F63 CUPX SERIES
CUPX-3 . . . . . . . . . . . .F63 CUPX SERIES
CUPX-4 . . . . . . . . . . . .F63 CUPX SERIES
CUPX-5 . . . . . . . . . . . .F63 CUPX SERIES
CUPX-6 . . . . . . . . . . . .F63 CUPX SERIES
CUPX-7 . . . . . . . . . . . .F63 CUPX SERIES
CUPX-8 . . . . . . . . . . . .F63 CUPX SERIES
CUPX-9 . . . . . . . . . . . .F63 CUPX SERIES
D2BLA1000 . . . . . . . .DE20 D2L/D2PC SERIES
D2BLA1015 . . . . . . . .DE20 D2L/D2PC SERIES
D2BLA1020 . . . . . . . .DE20 D2L/D2PC SERIES
D2BLA1030 . . . . . . . .DE20 D2L/D2PC SERIES
D2BLA2000 . . . . . . . .DE20 D2L/D2PC SERIES
D2BLA2015 . . . . . . . .DE20 D2L/D2PC SERIES
D2BLA2020 . . . . . . . .DE20 D2L/D2PC SERIES
D2BLA2030 . . . . . . . .DE20 D2L/D2PC SERIES
D2BLA3000 . . . . . . . .DE20 D2L/D2PC SERIES
D2BLA3015 . . . . . . . .DE20 D2L/D2PC SERIES
D2BLA3020 . . . . . . . .DE20 D2L/D2PC SERIES
D2BLA3030 . . . . . . . .DE20 D2L/D2PC SERIES
D2C SERIES . . . . . . . .C3-7 D2C SERIES
D2L SERIES . . . . .DE18-21 D2L/D2PC SERIES
D2PCSERIES ...........................DE18-21
DAG-100 . . . . . . . . . . . .L14 DV SERIES
DAG-200 . . . . . . . . . . . .L14 DV SERIES
DB-10106 . . . . . . . . . . . .E3 DB SERIES
DB-10148 . . . . . . . . . . . .E3 DB SERIES
DB-12148 . . . . . . . . . . . .E3 DB SERIES
DB-12168 . . . . . . . . . . . .E3 DB SERIES
DB-12188 . . . . . . . . . . . .E3 DB SERIES
DB-12248 . . . . . . . . . . . .E3 DB SERIES
DB-16188 . . . . . . . . . . . .E3 DB SERIES
DB-16248 . . . . . . . . . . . .E3 DB SERIES
DB-16368 . . . . . . . . . . . .E3 DB SERIES
DB-20248 . . . . . . . . . . . .E3 DB SERIES
DB-203010 . . . . . . . . . . .E3 DB SERIES
DB-243010 . . . . . . . . . . .E3 DB SERIES
DB-243610 . . . . . . . . . . .E3 DB SERIES
DB-6126 . . . . . . . . . . . . .E3 DB SERIES
DB-664 . . . . . . . . . . . . . .E3 DB SERIES
DB-8106 . . . . . . . . . . . . .E3 DB SERIES
DB-8146 . . . . . . . . . . . . .E3 DB SERIES
DB-8188 . . . . . . . . . . . . .E3 DB SERIES
DB-884 . . . . . . . . . . . . . .E3 DB SERIES
DB-886 . . . . . . . . . . . . . .E3 DB SERIES
DBF32302 . . . . . . . . .L172 DBF SERIES
DBF32303 . . . . . . . . .L172 DBF SERIES
DBF4012 . . . . . . . . . . .L172 DBF SERIES
DBF4013 . . . . . . . . . . .L172 DBF SERIES
DBF4042 . . . . . . . . . . .L172 DBF SERIES
DBF4043 . . . . . . . . . . .L172 DBF SERIES
DBF6012 . . . . . . . . . . .L172 DBF SERIES
DBF6013 . . . . . . . . . . .L172 DBF SERIES
DBF6042 . . . . . . . . . . .L172 DBF SERIES
DBF6043 . . . . . . . . . . .L172 DBF SERIES
DBF-DL . . . . . . . . . . . .L172 DBF SERIES
DBFESERIES...............................L208
DBF-HUB . . . . . . . . . .L172 DBF SERIES
DCGE-10 . . . . . . . . . . .L14 DV SERIES
DCGE-20 . . . . . . . . . . .L14 DV SERIES
DE3BSERIES...........................L199-204
DE3B0013E10 . . . . . .L202 DE3B SERIES
DE3B0026E10 . . . . . .L202 DE3B SERIES
DE3B1313E01 . . . . . .L202 DE3B SERIES
DE3B2613E01 . . . . . .L202 DE3B SERIES
DE3B2626E01 . . . . . .L202 DE3B SERIES
DE4BSERIES...........................L199-204
DEDS-100 . . . . . . . . . .DE7 DEDS SERIES
DEDS-100A . . . . . . . . .DE7 DEDS SERIES
DEDS-100AA . . . . . . . .DE7 DEDS SERIES
DEDS-30 . . . . . . . . . . .DE7 DEDS SERIES
DEDS-30A . . . . . . . . . .DE7 DEDS SERIES
DEDS-30AA . . . . . . . . .DE7 DEDS SERIES
DEDS-60 . . . . . . . . . . .DE7 DEDS SERIES
DEDS-60A . . . . . . . . . .DE7 DEDS SERIES
DEDS-60AA . . . . . . . . .DE7 DEDS SERIES
DEDS-A . . . . . . . . . . . .DE7 DEDS SERIES
DEDS-B . . . . . . . . . . . .DE7 DEDS SERIES
DMSP101 . . . . . . . . . .L188 DM FLOODLIGHT SER
DS-1 . . . . . . . . . . . . . . .F29 DS SERIES
DS-5 . . . . . . . . . . . . . . .F29 DS SERIES
DVA-110 . . . . . . . . . . . .L14 DV SERIES
DVA-120 . . . . . . . . . . . .L14 DV SERIES
DVA-210 . . . . . . . . . . . .L14 DV SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
INTRODUCTION
NUMERIC INDEX
N1
INTRODUCTION
NUMERIC INDEX
DVA-220 . . . . . . . . . . . .L14 DV SERIES
DVX-110 . . . . . . . . . . . .L14 DV SERIES
DVX-120 . . . . . . . . . . . .L14 DV SERIES
DVX-210 . . . . . . . . . . . .L14 DV SERIES
DVX-220 . . . . . . . . . . . .L14 DV SERIES
E17 . . . . . . . . . . . . . . . . .F5 DRUALOY 7 SERIES
E17SA . . . . . . . . . . . . . . .F5 DRUALOY 7 SERIES
E27 . . . . . . . . . . . . . . . . .F5 DRUALOY 7 SERIES
E27SA . . . . . . . . . . . . . . .F5 DRUALOY 7 SERIES
E37 . . . . . . . . . . . . . . . . .F5 DRUALOY 7 SERIES
E37SA . . . . . . . . . . . . . . .F5 DRUALOY 7 SERIES
EAC . . . . . . . . . . . . . . .L224 EAC SERIES
EACH12 . . . . . . . . . . .L224 EAC SERIES
EACH16 . . . . . . . . . . .L224 EAC SERIES
EBSERIES .............................L137-141
EBBSERIES ............................L212-213
EBB-BC . . . . . . . . . . . .L212 EBB SERIES
EBB-L12 . . . . . . . . . . .L212 EBB SERIES
EBB-PL . . . . . . . . . . . .L212 EBB SERIES
EBB-RB . . . . . . . . . . . .L212 EBB SERIES
EBB-TRANS . . . . . . . .L212 EBB SERIES
EBF131 . . . . . . . . . . . .L140 EB SERIES
EBF134 . . . . . . . . . . . .L140 EB SERIES
EBF261 . . . . . . . . . . . .L140 EB SERIES
EBF264 . . . . . . . . . . . .L140 EB SERIES
EBG-2-200 . . . . . . . . . .L16 E SERIES
EBRS . . . . . . . . . . .L26,141 MB SERIES
ECC050 . . . . . . . . . . . .F86 ECC SERIES
ECC075 . . . . . . . . . . . .F86 ECC SERIES
ECC100 . . . . . . . . . . . .F86 ECC SERIES
ECC125 . . . . . . . . . . . .F86 ECC SERIES
ECC150 . . . . . . . . . . . .F86 ECC SERIES
ECC200 . . . . . . . . . . . .F86 ECC SERIES
ECC250 . . . . . . . . . . . .F86 ECC SERIES
ECC300 . . . . . . . . . . . .F86 ECC SERIES
ECF-110 . . . . . . . . . . . .F67 ECF SERIES
ECF-112 . . . . . . . . . . . .F67 ECF SERIES
ECF-115 . . . . . . . . . . . .F67 ECF SERIES
ECF-118 . . . . . . . . . . . .F67 ECF SERIES
ECF-121 . . . . . . . . . . . .F67 ECF SERIES
ECF-124 . . . . . . . . . . . .F67 ECF SERIES
ECF-130 . . . . . . . . . . . .F67 ECF SERIES
ECF-136 . . . . . . . . . . . .F67 ECF SERIES
ECF-14 . . . . . . . . . . . . .F67 ECF SERIES
ECF-16 . . . . . . . . . . . . .F67 ECF SERIES
ECF-18 . . . . . . . . . . . . .F67 ECF SERIES
ECF-210 . . . . . . . . . . . .F67 ECF SERIES
ECF-212 . . . . . . . . . . . .F67 ECF SERIES
ECF-215 . . . . . . . . . . . .F67 ECF SERIES
ECF-218 . . . . . . . . . . . .F67 ECF SERIES
ECF-221 . . . . . . . . . . . .F67 ECF SERIES
ECF-224 . . . . . . . . . . . .F67 ECF SERIES
ECF-230 . . . . . . . . . . . .F67 ECF SERIES
ECF-236 . . . . . . . . . . . .F67 ECF SERIES
ECF-24 . . . . . . . . . . . . .F67 ECF SERIES
ECF-26 . . . . . . . . . . . . .F67 ECF SERIES
ECF-28 . . . . . . . . . . . . .F67 ECF SERIES
ECF-310 . . . . . . . . . . . .F67 ECF SERIES
ECF-312 . . . . . . . . . . . .F67 ECF SERIES
ECF-315 . . . . . . . . . . . .F67 ECF SERIES
ECF-318 . . . . . . . . . . . .F67 ECF SERIES
ECF-321 . . . . . . . . . . . .F67 ECF SERIES
ECF-324 . . . . . . . . . . . .F67 ECF SERIES
ECF-330 . . . . . . . . . . . .F67 ECF SERIES
ECF-336 . . . . . . . . . . . .F67 ECF SERIES
ECF-36 . . . . . . . . . . . . .F67 ECF SERIES
ECF-38 . . . . . . . . . . . . .F67 ECF SERIES
ECFUF-110 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-112 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-115 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-118 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-121 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-124 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-130 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-136 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-14 . . . . . . . . . . .F68 ECFUF SERIES
ECFUF-16 . . . . . . . . . . .F68 ECFUF SERIES
ECFUF-18 . . . . . . . . . . .F68 ECFUF SERIES
ECFUF-210 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-212 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-215 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-218 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-221 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-224 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-230 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-236 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-24 . . . . . . . . . . .F68 ECFUF SERIES
ECFUF-26 . . . . . . . . . . .F68 ECFUF SERIES
ECFUF-28 . . . . . . . . . . .F68 ECFUF SERIES
ECFUF-310 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-312 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-315 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-318 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-321 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-324 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-330 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-336 . . . . . . . . . .F68 ECFUF SERIES
ECFUF-36 . . . . . . . . . . .F68 ECFUF SERIES
ECFUF-38 . . . . . . . . . . .F68 ECFUF SERIES
EEQSERIES ................................L211
EGSA-200 . . . . . . . . . . .L16 E SERIES
EKJ-110 . . . . . . . . .F67,221 EKJ SERIES
EKJ-112 . . . . . . . . .F67,221 EKJ SERIES
EKJ-115 . . . . . . . . .F67,221 EKJ SERIES
EKJ-118 . . . . . . . . .F67,221 EKJ SERIES
EKJ-14 . . . . . . . . . .F67,221 EKJ SERIES
EKJ-16 . . . . . . . . . .F67,221 EKJ SERIES
EKJ-18 . . . . . . . . . .F67,221 EKJ SERIES
EKJ-210 . . . . . . . . .F67,221 EKJ SERIES
EKJ-212 . . . . . . . . .F67,221 EKJ SERIES
EKJ-215 . . . . . . . . .F67,221 EKJ SERIES
EKJ-218 . . . . . . . . .F67,221 EKJ SERIES
EKJ-24 . . . . . . . . . .F67,221 EKJ SERIES
EKJ-26 . . . . . . . . . .F67,221 EKJ SERIES
EKJ-28 . . . . . . . . . .F67,221 EKJ SERIES
EKJ-310 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-312 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-315 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-318 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-321 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-324 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-330 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-336 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-36 . . . . . . . . . . . . .F67 EKJ SERIES
EKJ-38 . . . . . . . . . . . . .F67 EKJ SERIES
EKJ-412 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-415 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-418 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-421 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-424 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-430 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-436 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-512 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-515 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-518 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-521 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-524 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-530 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-536 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-612 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-615 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-618 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-624 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-630 . . . . . . . . . . . .F67 EKJ SERIES
EKJ-636 . . . . . . . . . . . .F67 EKJ SERIES
EKJS-1012 . . . . . . . . . .F69 EKJS SERIES
EKJS-1015 . . . . . . . . . .F69 EKJS SERIES
EKJS-1018 . . . . . . . . . .F69 EKJS SERIES
EKJS-1021 . . . . . . . . . .F69 EKJS SERIES
EKJS-1024 . . . . . . . . . .F69 EKJS SERIES
EKJS-1027 . . . . . . . . . .F69 EKJS SERIES
EKJS-1030 . . . . . . . . . .F69 EKJS SERIES
EKJS-1036 . . . . . . . . . .F69 EKJS SERIES
EKJS-712 . . . . . . . . . . .F69 EKJS SERIES
EKJS-715 . . . . . . . . . . .F69 EKJS SERIES
EKJS-718 . . . . . . . . . . .F69 EKJS SERIES
EKJS-721 . . . . . . . . . . .F69 EKJS SERIES
EKJS-724 . . . . . . . . . . .F69 EKJS SERIES
EKJS-727 . . . . . . . . . . .F69 EKJS SERIES
EKJS-730 . . . . . . . . . . .F69 EKJS SERIES
EKJS-736 . . . . . . . . . . .F69 EKJS SERIES
EKJS-812 . . . . . . . . . . .F69 EKJS SERIES
EKJS-815 . . . . . . . . . . .F69 EKJS SERIES
EKJS-818 . . . . . . . . . . .F69 EKJS SERIES
EKJS-821 . . . . . . . . . . .F69 EKJS SERIES
EKJS-824 . . . . . . . . . . .F69 EKJS SERIES
EKJS-827 . . . . . . . . . . .F69 EKJS SERIES
EKJS-830 . . . . . . . . . . .F69 EKJS SERIES
EKJS-833 . . . . . . . . . . .F69 EKJS SERIES
EKJS-836 . . . . . . . . . . .F69 EKJS SERIES
EKJUF-412 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-415 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-418 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-421 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-424 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-430 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-436 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-512 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-515 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-518 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-521 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-524 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-530 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-536 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-612 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-615 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-618 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-624 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-630 . . . . . . . . . .F68 EKJUF SERIES
EKJUF-636 . . . . . . . . . .F68 EKJUF SERIES
EMSERIES.............................L137-141
EMG1 . . . . . . . . . . . . .L140 EM/EB/EQ SERIES
EMG2 . . . . . . . . .L134,140 EM/EB/EQ SERIES
EMGS1 . . . . . . . . . . . .L141 EM/EB/EQ SERIES
EMGS2 . . . . . . . .L134,141 EM/EB/EQ SERIES
EMGS3 . . . . . . . .L134,141 EM/EB/EQ SERIES
EMH050 . . . . . . . . . . .L140 EM SERIES
EMH070 . . . . . . . . . . .L140 EM SERIES
EMH100 . . . . . . . . . . .L140 EM SERIES
EMHP071 . . . . . . . . . .L188 EM FLOODLIGHT SERIES
EMI15 . . . . . . . . . . . . .L140 EM SERIES
EMI20 . . . . . . . . . . . . .L140 EM SERIES
EMI30 . . . . . . . . . . . . .L140 EM SERIES
EMIP111 . . . . . . . . . . .L188 EM FLOODLIGHT SERIES
EMLSERIES............................L132-134
EML4530 . . . . . . . . . .L134 EML SERIES
EMLC4530 . . . . . . . . .L134 EML SERIES
EMRS . . . . . . . . . . .L26,141 MB SERIES
EMS050 . . . . . . . . . . .L140 EM SERIES
EMS070 . . . . . . . . . . .L140 EM SERIES
EMS075 . . . . . . . . . . .L140 EM SERIES
EMS100 . . . . . . . . . . .L140 EM SERIES
EMS105 . . . . . . . . . . .L140 EM SERIES
EMS151 . . . . . . . . . . .L140 EM SERIES
EMS351 . . . . . . . . . . .L140 EM SERIES
EMSP151 . . . . . . . . . .L188 EM FLOODLIGHT SERIES
ENY-1 . . . . . . . . . . . . . .F45 ENY SERIES
ENY-1M . . . . . . . . . . . .F45 ENY SERIES
ENY-1-T . . . . . . . . . . . .F45 ENY SERIES
ENY-1TM . . . . . . . . . . .F45 ENY SERIES
ENY-2 . . . . . . . . . . . . . .F45 ENY SERIES
ENY-2M . . . . . . . . . . . .F45 ENY SERIES
ENY-2SET . . . . . . .L26,222 ENY SERIES
ENY-2-T . . . . . . . . . . . .F45 ENY SERIES
ENY-2TM . . . . . . . . . . .F45 ENY SERIES
ENY-3 . . . . . . . . . . . . . .F45 ENY SERIES
ENY-3M . . . . . . . . . . . .F45 ENY SERIES
ENY-3SET . . . . . . .L26,222 ENY SERIES
ENY-3-T . . . . . . . . . . . .F45 ENY SERIES
ENY-3TM . . . . . . . . . . .F45 ENY SERIES
ENY-4 . . . . . . . . . . . . . .F45 ENY SERIES
ENY40-0 . . . . . . . . . . . .F47 ENY40 SERIES
ENY40-0M . . . . . . . . . .F47 ENY40 SERIES
ENY40-1 . . . . . . . . . . . .F47 ENY40 SERIES
ENY40-1M . . . . . . . . . .F47 ENY40 SERIES
ENY40-2 . . . . . . . . . . . .F47 ENY40 SERIES
ENY40-2M . . . . . . . . . .F47 ENY40 SERIES
ENY40-3 . . . . . . . . . . . .F47 ENY40 SERIES
ENY40-3M . . . . . . . . . .F47 ENY40 SERIES
ENY40-4 . . . . . . . . . . . .F47 ENY40 SERIES
ENY40-4M . . . . . . . . . .F47 ENY40 SERIES
ENY40-5 . . . . . . . . . . . .F47 ENY40 SERIES
ENY40-5M . . . . . . . . . .F47 ENY40 SERIES
ENY40-6 . . . . . . . . . . . .F47 ENY40 SERIES
ENY40-6M . . . . . . . . . .F47 ENY40 SERIES
ENY40-7 . . . . . . . . . . . .F47 ENY40 SERIES
ENY40-7M . . . . . . . . . .F47 ENY40 SERIES
ENY40-8 . . . . . . . . . . . .F47 ENY40 SERIES
ENY40-8M . . . . . . . . . .F47 ENY40 SERIES
ENY40-9 . . . . . . . . . . . .F47 ENY40 SERIES
ENY40-9M . . . . . . . . . .F47 ENY40 SERIES
ENY-4M . . . . . . . . . . . .F45 ENY SERIES
ENY-4-T . . . . . . . . . . . .F45 ENY SERIES
ENY-4TM . . . . . . . . . . .F45 ENY SERIES
ENY-5 . . . . . . . . . . . . . .F45 ENY SERIES
ENY-5M . . . . . . . . . . . .F45 ENY SERIES
ENY-5-T . . . . . . . . . . . .F45 ENY SERIES
ENY-5TM . . . . . . . . . . .F45 ENY SERIES
ENY-6 . . . . . . . . . . . . . .F45 ENY SERIES
ENY-6M . . . . . . . . . . . .F45 ENY SERIES
ENY-6-T . . . . . . . . . . . .F45 ENY SERIES
ENY-6TM . . . . . . . . . . .F45 ENY SERIES
EPG-2-200 . . . . . . . . . .L16 E SERIES
EQSERIES .............................L137-141
EQF2630 . . . . . . . . . . .L140 EQ SERIES
EQF3230 . . . . . . . . . . .L140 EQ SERIES
EQF4230 . . . . . . . . . . .L140 EQ SERIES
EQF5230 . . . . . . . . . . .L140 EQ SERIES
EQF6430 . . . . . . . . . . .L140 EQ SERIES
EQF8430 . . . . . . . . . . .L140 EQ SERIES
ERA15 . . . . . . . . . . . . .L140 EM/EB/EQ SERIES
ERA30 . . . . . . . . .L134,140 EM/EB/EQ SERIES
ERSD15 . . . . . . . . . . .L140 EM/EB/EQ SERIES
ERSD30 . . . . . . . .L134,140 EM/EB/EQ SERIES
ESXSERIES ............................L214-215
ESX120PS . . . . . . . . .L214 ESX SERIES
ESX1274PS . . . . . . . .L214 ESX SERIES
ESX240PS . . . . . . . . .L214 ESX SERIES
ESXAL . . . . . . . . . . . . .L214 ESX SERIES
ESXBL . . . . . . . . . . . . .L214 ESX SERIES
ESXCL . . . . . . . . . . . .L214 ESX SERIES
ESXGL . . . . . . . . . . . .L214 ESX SERIES
ESXRL . . . . . . . . . . . . .L214 ESX SERIES
EXB-10106 N34 . . . . . .E10 EXB SERIES
EXB-10108 N34 . . . . . .E10 EXB SERIES
EXB-10146 N34 . . . . . .E10 EXB SERIES
EXB-10148 N34 . . . . . .E10 EXB SERIES
EXB-12126 N34 . . . . . .E10 EXB SERIES
EXB-12128 N34 . . . . . .E10 EXB SERIES
EXB-12186 N34 . . . . . .E10 EXB SERIES
EXB-12188 N34 . . . . . .E10 EXB SERIES
EXB-122412 N34 . . . . .E10 EXB SERIES
EXB-12246 N34 . . . . . .E10 EXB SERIES
EXB-12248 N34 . . . . . .E10 EXB SERIES
EXB-123610 N34 . . . . .E10 EXB SERIES
EXB-12368 N34 . . . . . .E10 EXB SERIES
EXB-14146 N34 . . . . . .E10 EXB SERIES
EXB-14148 N34 . . . . . .E10 EXB SERIES
EXB-16166 N34 . . . . . .E10 EXB SERIES
EXB-16168 N34 . . . . . .E10 EXB SERIES
EXB-162410 N34 . . . . .E10 EXB SERIES
EXB-16248 N34 . . . . . .E10 EXB SERIES
EXB-18186 N34 . . . . . .E10 EXB SERIES
EXB-18188 N34 . . . . . .E10 EXB SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
N2
INTRODUCTION
NUMERIC INDEX
EXB-182410 N34 . . . . .E10 EXB SERIES
EXB-18248 N34 . . . . . .E10 EXB SERIES
EXB-18308 N34 . . . . . .E10 EXB SERIES
EXB-183610 N34 . . . . .E10 EXB SERIES
EXB-18368 N34 . . . . . .E10 EXB SERIES
EXB-203611 N34 . . . . .E10 EXB SERIES
EXB-242410 N34 . . . . .E10 EXB SERIES
EXB-24248 N34 . . . . . .E10 EXB SERIES
EXB-24308 N34 . . . . . .E10 EXB SERIES
EXB-243610 N34 . . . . .E10 EXB SERIES
EXB-24368 N34 . . . . . .E10 EXB SERIES
EXB-6124 N34 . . . . . . .E10 EXB SERIES
EXB-664 N34 . . . . . . . .E10 EXB SERIES
EXB-684 N34 . . . . . . . .E10 EXB SERIES
EXB-8104 N34 . . . . . . .E10 EXB SERIES
EXB-8106 N34 . . . . . . .E10 EXB SERIES
EXB-8126 N34 . . . . . . .E10 EXB SERIES
EXB-8128 N34 . . . . . . .E10 EXB SERIES
EXB-886 N34 . . . . . . . .E10 EXB SERIES
EXB-FDS-0303P . . . .DE10 EXB-NFD/EXB-FDS SER
EXB-FDS-0603P . . . .DE10 EXB-NFD/EXB-FDS SER
EXB-FDS-1003P . . . .DE10 EXB-NFD/EXB-FDS SER
EXB-FDS-2003P . . . .DE10 EXB-NFD/EXB-FDS SER
EXB-FDS-4003P . . . .DE10 EXB-NFD/EXB-FDS SER
EXBLI SERIES . . .DE22-23 EXBLI/EXBPI SER
EXB-NFD-0303P . . . .DE10 EXB-NFD/EXB-FDS SER
EXB-NFD-0303PDT . .DE10 EXB-NFD/EXB-FDS SER
EXB-NFD-0306P . . . .DE10 EXB-NFD/EXB-FDS SER
EXB-NFD-0603P . . . .DE10 EXB-NFD/EXB-FDS SER
EXB-NFD-0603PDT . .DE10 EXB-NFD/EXB-FDS SER
EXB-NFD-0606P . . . .DE10 EXB-NFD/EXB-FDS SER
EXB-NFD-1003P . . . .DE10 EXB-NFD/EXB-FDS SER
EXB-NFD-1003PDT . .DE10 EXB-NFD/EXB-FDS SER
EXB-NFD-1006P . . . .DE10 EXB-NFD/EXB-FDS SER
EXB-NFD-2003P . . . .DE10 EXB-NFD/EXB-FDS SER
EXB-NFD-4003P . . . .DE10 EXB-NFD/EXB-FDS SER
EXBPISERIES ...........................DE22-23
EXG-2-200 . . . . . . . . . .L16 E SERIES
EXH1A10 . . . . . . . . . . .E21 EXH SERIES
EXH1A6 . . . . . . . . . . . .E21 EXH SERIES
EXH1A8 . . . . . . . . . . . .E21 EXH SERIES
EXH1B10 . . . . . . . . . . .E21 EXH SERIES
EXH1B8 . . . . . . . . . . . .E21 EXH SERIES
EXH2C10 . . . . . . . . . . .E21 EXH SERIES
EXH2C8 . . . . . . . . . . . .E21 EXH SERIES
EXH3D10 . . . . . . . . . . .E21 EXH SERIES
EXH3D8 . . . . . . . . . . . .E21 EXH SERIES
EXH3E10 . . . . . . . . . . . .E21 EXH SERIES
EY-0 . . . . . . . . . . . . . . .F46 EY SERIES
EY-0M . . . . . . . . . . . . . .F46 EY SERIES
EY-0-T . . . . . . . . . . . . . .F46 EY SERIES
EY-0TM . . . . . . . . . . . . .F46 EY SERIES
EY-1 . . . . . . . . . . . . . . .F46 EY SERIES
EY-1M . . . . . . . . . . . . . .F46 EY SERIES
EY-1-T . . . . . . . . . . . . . .F46 EY SERIES
EY-1TM . . . . . . . . . . . . .F46 EY SERIES
EY-2 . . . . . . . . . . . . . . .F46 EY SERIES
EY-2M . . . . . . . . . . . . . .F46 EY SERIES
EY-2-T . . . . . . . . . . . . . .F46 EY SERIES
EY-2TM . . . . . . . . . . . . .F46 EY SERIES
EY-3 . . . . . . . . . . . . . . .F46 EY SERIES
EY-3M . . . . . . . . . . . . . .F46 EY SERIES
EY-3-T . . . . . . . . . . . . . .F46 EY SERIES
EY-3TM . . . . . . . . . . . . .F46 EY SERIES
EY-4 . . . . . . . . . . . . . . .F46 EY SERIES
EY-4M . . . . . . . . . . . . . .F46 EY SERIES
EY-4-T . . . . . . . . . . . . . .F46 EY SERIES
EY-4TM . . . . . . . . . . . . .F46 EY SERIES
EY-5 . . . . . . . . . . . . . . .F46 EY SERIES
EY-5M . . . . . . . . . . . . . .F46 EY SERIES
EY-5-T . . . . . . . . . . . . . .F46 EY SERIES
EY-5TM . . . . . . . . . . . . .F46 EY SERIES
EY-6 . . . . . . . . . . . . . . .F46 EY SERIES
EY-6M . . . . . . . . . . . . . .F46 EY SERIES
EY-6-T . . . . . . . . . . . . . .F46 EY SERIES
EY-6TM . . . . . . . . . . . . .F46 EY SERIES
EY-7 . . . . . . . . . . . . . . .F46 EY SERIES
EY-7M . . . . . . . . . . . . . .F46 EY SERIES
EY-7-T . . . . . . . . . . . . . .F46 EY SERIES
EY-7TM . . . . . . . . . . . . .F46 EY SERIES
EY-8 . . . . . . . . . . . . . . .F46 EY SERIES
EY-8M . . . . . . . . . . . . . .F46 EY SERIES
EY-8-T . . . . . . . . . . . . . .F46 EY SERIES
EY-8TM . . . . . . . . . . . . .F46 EY SERIES
EY-9 . . . . . . . . . . . . . . .F46 EY SERIES
EY-9M . . . . . . . . . . . . . .F46 EY SERIES
EY-9-T . . . . . . . . . . . . . .F46 EY SERIES
EY-9TM . . . . . . . . . . . . .F46 EY SERIES
EYD-0 . . . . . . . . . . . . . .F46 EYD SERIES
EYD-0M . . . . . . . . . . . .F46 EYD SERIES
EYD-0-T . . . . . . . . . . . .F46 EYD SERIES
EYD-0TM . . . . . . . . . . .F46 EYD SERIES
EYD-1 . . . . . . . . . . . . . .F46 EYD SERIES
EYD-1M . . . . . . . . . . . .F46 EYD SERIES
EYD-1-T . . . . . . . . . . . .F46 EYD SERIES
EYD-1TM . . . . . . . . . . .F46 EYD SERIES
EYD-2 . . . . . . . . . . . . . .F46 EYD SERIES
EYD-2M . . . . . . . . . . . .F46 EYD SERIES
EYD-2-T . . . . . . . . . . . .F46 EYD SERIES
EYD-2TM . . . . . . . . . . .F46 EYD SERIES
EYD-3 . . . . . . . . . . . . . .F46 EYD SERIES
EYD-3M . . . . . . . . . . . .F46 EYD SERIES
EYD-3-T . . . . . . . . . . . .F46 EYD SERIES
EYD-3TM . . . . . . . . . . .F46 EYD SERIES
EYD-4 . . . . . . . . . . . . . .F46 EYD SERIES
EYD40-0 . . . . . . . . . . . .F47 EYD40 SERIES
EYD40-0M . . . . . . . . . .F47 EYD40 SERIES
EYD40-1 . . . . . . . . . . . .F47 EYD40 SERIES
EYD40-1M . . . . . . . . . .F47 EYD40 SERIES
EYD40-2 . . . . . . . . . . . .F47 EYD40 SERIES
EYD40-2M . . . . . . . . . .F47 EYD40 SERIES
EYD40-3 . . . . . . . . . . . .F47 EYD40 SERIES
EYD40-3M . . . . . . . . . .F47 EYD40 SERIES
EYD40-4 . . . . . . . . . . . .F47 EYD40 SERIES
EYD40-4M . . . . . . . . . .F47 EYD40 SERIES
EYD40-5 . . . . . . . . . . . .F47 EYD40 SERIES
EYD40-5M . . . . . . . . . .F47 EYD40 SERIES
EYD40-6 . . . . . . . . . . . .F47 EYD40 SERIES
EYD40-6M . . . . . . . . . .F47 EYD40 SERIES
EYD40-7 . . . . . . . . . . . .F47 EYD40 SERIES
EYD40-7M . . . . . . . . . .F47 EYD40 SERIES
EYD40-8 . . . . . . . . . . . .F47 EYD40 SERIES
EYD40-8M . . . . . . . . . .F47 EYD40 SERIES
EYD40-9 . . . . . . . . . . . .F47 EYD40 SERIES
EYD40-9M . . . . . . . . . .F47 EYD40 SERIES
EYD-4M . . . . . . . . . . . .F46 EYD SERIES
EYD-4-T . . . . . . . . . . . .F46 EYD SERIES
EYD-4TM . . . . . . . . . . .F46 EYD SERIES
EYD-5 . . . . . . . . . . . . . .F46 EYD SERIES
EYD-5M . . . . . . . . . . . .F46 EYD SERIES
EYD-5-T . . . . . . . . . . . .F46 EYD SERIES
EYD-5TM . . . . . . . . . . .F46 EYD SERIES
EYD-6 . . . . . . . . . . . . . .F46 EYD SERIES
EYD-6M . . . . . . . . . . . .F46 EYD SERIES
EYD-6-T . . . . . . . . . . . .F46 EYD SERIES
EYD-6TM . . . . . . . . . . .F46 EYD SERIES
EYD-7 . . . . . . . . . . . . . .F46 EYD SERIES
EYD-7M . . . . . . . . . . . .F46 EYD SERIES
EYD-7-T . . . . . . . . . . . .F46 EYD SERIES
EYD-7TM . . . . . . . . . . .F46 EYD SERIES
EYD-8 . . . . . . . . . . . . . .F46 EYD SERIES
EYD-8M . . . . . . . . . . . .F46 EYD SERIES
EYD-8-T . . . . . . . . . . . .F46 EYD SERIES
EYD-8TM . . . . . . . . . . .F46 EYD SERIES
EYD-9 . . . . . . . . . . . . . .F46 EYD SERIES
EYD-9M . . . . . . . . . . . .F46 EYD SERIES
EYD-9-T . . . . . . . . . . . .F46 EYD SERIES
EYD-9TM . . . . . . . . . . .F46 EYD SERIES
EYMF-1 . . . . . . . . . . . .F66 EYMF SERIES
EYMF-2 . . . . . . . . . . . .F66 EYMF SERIES
EYS-0 . . . . . . . . . . . . . .F45 EYS SERIES
EYS-0M . . . . . . . . . . . .F45 EYS SERIES
EYS-0-T . . . . . . . . . . . .F45 EYS SERIES
EYS-0TM . . . . . . . . . . .F45 EYS SERIES
EYS-1 . . . . . . . . . . . . . .F45 EYS SERIES
EYS-1-T . . . . . . . . . . . .F45 EYS SERIES
EYS-2 . . . . . . . . . . . . . .F45 EYS SERIES
EYS-2-T . . . . . . . . . . . .F45 EYS SERIES
EYS-3 . . . . . . . . . . . . . .F45 EYS SERIES
EYS-3-T . . . . . . . . . . . .F45 EYS SERIES
EYS-4 . . . . . . . . . . . . . .F45 EYS SERIES
EYS-4-T . . . . . . . . . . . .F45 EYS SERIES
EYS-5 . . . . . . . . . . . . . .F45 EYS SERIES
EYS-5-T . . . . . . . . . . . .F45 EYS SERIES
EYS-6 . . . . . . . . . . . . . .F45 EYS SERIES
EYS-6-T . . . . . . . . . . . .F45 EYS SERIES
EYS-7 . . . . . . . . . . . . . .F45 EYS SERIES
EYS-7M . . . . . . . . . . . .F45 EYS SERIES
EYS-7-T . . . . . . . . . . . .F45 EYS SERIES
EYS-7TM . . . . . . . . . . .F45 EYS SERIES
EYS-8 . . . . . . . . . . . . . .F45 EYS SERIES
EYS-8M . . . . . . . . . . . .F45 EYS SERIES
EYS-8-T . . . . . . . . . . . .F45 EYS SERIES
EYS-8TM . . . . . . . . . . .F45 EYS SERIES
EYS-9 . . . . . . . . . . . . . .F45 EYS SERIES
EYS-9M . . . . . . . . . . . .F45 EYS SERIES
EYS-9-T . . . . . . . . . . . .F45 EYS SERIES
EYS-9TM . . . . . . . . . . .F45 EYS SERIES
EZSERIES .............................L156-161
EZA2 . . . . . . .L134,140,160 EZ SERIES
EZA3 . . . . . . .L134,140,160 EZ SERIES
EZB2 . . . . . . .L134,140,160 EZ SERIES
EZB3 . . . . . . .L134,140,160 EZ SERIES
EZBA12 . . . . . . . . . . . .L224 EZBA SERIES
EZCB . . . . . . . . . .L141,161 EZ SERIES
EZCUP . . . . . . . . .L140,160 EZ SERIES
EZD4 . . . . . . .L134,140,160 EZ SERIES
EZD4A . . . . .L134,140,160 EZ SERIES
EZG1 . . . . . . . . . . . . . .L161 EZ SERIES
EZGS1 . . . . . . . . . . . . .L160 EZ SERIES
EZGS2 . . . . . . . . . . . . .L160 EZ SERIES
EZH070 . . . . . . . . . . . .L162 EZ SERIES
EZH075 . . . . . . . . . . . .L162 EZ SERIES
EZH076 . . . . . . . . . . . .L162 EZ SERIES
EZH078 . . . . . . . . . . . .L162 EZ SERIES
EZH100 . . . . . . . . . . . .L162 EZ SERIES
EZH105 . . . . . . . . . . . .L162 EZ SERIES
EZH106 . . . . . . . . . . . .L162 EZ SERIES
EZH108 . . . . . . . . . . . .L162 EZ SERIES
EZH170 . . . . . . . . . . . .L162 EZ SERIES
EZH175 . . . . . . . . . . . .L162 EZ SERIES
EZH176 . . . . . . . . . . . .L162 EZ SERIES
EZH178 . . . . . . . . . . . .L162 EZ SERIES
EZH250 . . . . . . . . . . . .L162 EZ SERIES
EZH255 . . . . . . . . . . . .L162 EZ SERIES
EZH256 . . . . . . . . . . . .L162 EZ SERIES
EZH258 . . . . . . . . . . . .L162 EZ SERIES
EZH400 . . . . . . . . . . . .L162 EZ SERIES
EZH405 . . . . . . . . . . . .L162 EZ SERIES
EZH406 . . . . . . . . . . . .L162 EZ SERIES
EZH408 . . . . . . . . . . . .L162 EZ SERIES
EZMO . . . . . . . . . . . . .L161 EZ SERIES
EZP150 . . . . . . . . . . . .L162 EZ SERIES
EZP155 . . . . . . . . . . . .L162 EZ SERIES
EZP156 . . . . . . . . . . . .L162 EZ SERIES
EZP158 . . . . . . . . . . . .L162 EZ SERIES
EZP170 . . . . . . . . . . . .L162 EZ SERIES
EZP175 . . . . . . . . . . . .L162 EZ SERIES
EZP176 . . . . . . . . . . . .L162 EZ SERIES
EZP178 . . . . . . . . . . . .L162 EZ SERIES
EZP250 . . . . . . . . . . . .L162 EZ SERIES
EZP255 . . . . . . . . . . . .L162 EZ SERIES
EZP256 . . . . . . . . . . . .L162 EZ SERIES
EZP258 . . . . . . . . . . . .L162 EZ SERIES
EZP320 . . . . . . . . . . . .L162 EZ SERIES
EZP325 . . . . . . . . . . . .L162 EZ SERIES
EZP326 . . . . . . . . . . . .L162 EZ SERIES
EZP328 . . . . . . . . . . . .L162 EZ SERIES
EZP350 . . . . . . . . . . . .L162 EZ SERIES
EZP355 . . . . . . . . . . . .L162 EZ SERIES
EZP356 . . . . . . . . . . . .L162 EZ SERIES
EZP358 . . . . . . . . . . . .L162 EZ SERIES
EZP400 . . . . . . . . . . . .L162 EZ SERIES
EZP405 . . . . . . . . . . . .L162 EZ SERIES
EZP406 . . . . . . . . . . . .L162 EZ SERIES
EZP408 . . . . . . . . . . . .L162 EZ SERIES
EZS050 . . . . . . . . . . . .L162 EZ SERIES
EZS058 . . . . . . . . . . . .L162 EZ SERIES
EZS070 . . . . . . . . . . . .L162 EZ SERIES
EZS075 . . . . . . . . . . . .L162 EZ SERIES
EZS076 . . . . . . . . . . . .L162 EZ SERIES
EZS078 . . . . . . . . . . . .L162 EZ SERIES
EZS100 . . . . . . . . . . . .L162 EZ SERIES
EZS105 . . . . . . . . . . . .L162 EZ SERIES
EZS106 . . . . . . . . . . . .L162 EZ SERIES
EZS108 . . . . . . . . . . . .L162 EZ SERIES
EZS150 . . . . . . . . . . . .L162 EZ SERIES
EZS155 . . . . . . . . . . . .L162 EZ SERIES
EZS156 . . . . . . . . . . . .L162 EZ SERIES
EZS158 . . . . . . . . . . . .L162 EZ SERIES
EZS250 . . . . . . . . . . . .L162 EZ SERIES
EZS255 . . . . . . . . . . . .L162 EZ SERIES
EZS256 . . . . . . . . . . . .L162 EZ SERIES
EZS258 . . . . . . . . . . . .L162 EZ SERIES
EZS400 . . . . . . . . . . . .L162 EZ SERIES
EZS405 . . . . . . . . . . . .L162 EZ SERIES
EZS406 . . . . . . . . . . . .L162 EZ SERIES
EZS408 . . . . . . . . . . . .L162 EZ SERIES
EZ-TSERIES ...........................L196-197
EZTB . . . . . . . . . .L141,161 EZ SERIES
EZX2 . . . . . . .L134,140,160 EZ SERIES
EZX3 . . . . . . .L134,140,160 EZ SERIES
FB-707 . . . . . . . . . . . . .F30 FB SERIES
FB-714 . . . . . . . . . . . . .F30 FB SERIES
FB-724 . . . . . . . . . . . . .F30 FB SERIES
FB-734 . . . . . . . . . . . . .F30 FB SERIES
FB-745 . . . . . . . . . . . . .F30 FB SERIES
FB-765 . . . . . . . . . . . . .F30 FB SERIES
FB-787 . . . . . . . . . . . . .F30 FB SERIES
FCLA . . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
FCLA2 . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
FCLG . . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
FCL-GF . . . . . . . . . .F41,42 FS/FD SER DEV CVRS
FCLM . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
FCLN . . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
FCLR . . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
FCLT . . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
FCL-VG . . . . . . . . . .F41,42 FS/FD SER DEV CVRS
FD-1 . . . . . . . . . . . . . . .F31 FD SERIES
FD-1M . . . . . . . . . . . . .F31 FD SERIES
FD-2 . . . . . . . . . . . . . . .F31 FD SERIES
FD-2M . . . . . . . . . . . . .F31 FD SERIES
FD-3 . . . . . . . . . . . . . . .F31 FD SERIES
FD-3M . . . . . . . . . . . . .F31 FD SERIES
FDA-2 . . . . . . . . . . . . . .F34 FDA SERIES
FDC-1 . . . . . . . . . . . . . .F32 FDC SERIES
FDC-1M . . . . . . . . . . . .F32 FDC SERIES
FDC-2 . . . . . . . . . . . . . .F32 FDC SERIES
FDC-2M . . . . . . . . . . . .F32 FDC SERIES
FDC-3 . . . . . . . . . . . . . .F32 FDC SERIES
FDC-3M . . . . . . . . . . . .F32 FDC SERIES
FDCC-2 . . . . . . . . . . . .F35 FDCC SERIES
FDCC-2M . . . . . . . . . . .F35 FDCC SERIES
FDQ . . . . . . . . . . . . .F38,39 FDQ SERIES
FDS-2 . . . . . . . . . . . . . .F35 FDS SERIES
FDS-2M . . . . . . . . . . . .F35 FDS SERIES
FF-45-1 . . . . . . . . . . . . .F66 FF SERIES
FF-45-1M . . . . . . . . . . .F66 FF SERIES
FF-45-2 . . . . . . . . . . . . .F66 FF SERIES
FF-45-2M . . . . . . . . . . .F66 FF SERIES
FF-45-3 . . . . . . . . . . . . .F66 FF SERIES
FF-45-3M . . . . . . . . . . .F66 FF SERIES
FF-45-6 . . . . . . . . . . . . .F66 FF SERIES
FF-45-6 . . . . . . . . . . . . .F66 FF SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
N3
INTRODUCTION
NUMERIC INDEX
FF-45-8 . . . . . . . . . . . . .F66 FF SERIES
FF-45-8M . . . . . . . . . . .F66 FF SERIES
FF-90-1 . . . . . . . . . . . . .F66 FF SERIES
FF-90-1M . . . . . . . . . . .F66 FF SERIES
FF-90-2 . . . . . . . . . . . . .F66 FF SERIES
FF-90-2M . . . . . . . . . . .F66 FF SERIES
FF-90-3 . . . . . . . . . . . . .F66 FF SERIES
FF-90-3M . . . . . . . . . . .F66 FF SERIES
FH-2 . . . . . . . . . . . . . .L220 FH SERIES
FHC-21 . . . . . . . . . . . .L219 FHC SERIES
FHC-22 . . . . . . . . . . . .L219 FHC SERIES
FHT-21 . . . . . . . . . . . .L219 FHT SERIES
FHT-22 . . . . . . . . . . . .L219 FHT SERIES
FKA-22 . . . . . . . . . . . .L219 FKA SERIES
FS-1 . . . . . . . . . . . . . . .F31 FS SERIES
FS-1M . . . . . . . . . . . . . .F31 FS SERIES
FS-2 . . . . . . . . . . . . . . .F31 FS SERIES
FS-2M . . . . . . . . . . . . . .F31 FS SERIES
FS-3 . . . . . . . . . . . . . . .F31 FS SERIES
FS-3M . . . . . . . . . . . . . .F31 FS SERIES
FSA-1 . . . . . . . . . . . . . .F34 FDA SERIES
FSA-2 . . . . . . . . . . . . . .F34 FDA SERIES
FSBC . . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
FSBCM . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
FSC-1 . . . . . . . . . . . . . .F31 FSC SERIES
FSC-1M . . . . . . . . . . . .F31 FSC SERIES
FSC-2 . . . . . . . . . . . . . .F31 FSC SERIES
FSC-2M . . . . . . . . . . . .F31 FSC SERIES
FSC-3 . . . . . . . . . . . . . .F31 FSC SERIES
FSC-3M . . . . . . . . . . . .F31 FSC SERIES
FSCA-1 . . . . . . . . . . . . .F36 FSCA SERIES
FSCA-1M . . . . . . . . . . .F36 FSCA SERIES
FSCA-2 . . . . . . . . . . . . .F36 FSCA SERIES
FSCA-2M . . . . . . . . . . .F36 FSCA SERIES
FSCC-1 . . . . . . . . . . . . .F35 FSCC SERIES
FSCC-1M . . . . . . . . . . .F35 FSCC SERIES
FSCC-2 . . . . . . . . . . . . .F35 FSCC SERIES
FSCC-2M . . . . . . . . . . .F35 FSCC SERIES
FSCT-1 . . . . . . . . . . . . .F36 FSCT SERIES
FSCT-1M . . . . . . . . . . .F36 FSCT SERIES
FSCT-2 . . . . . . . . . . . . .F36 FSCT SERIES
FSCT-2M . . . . . . . . . . .F36 FSCT SERIES
FSL-1 . . . . . . . . . . . . . .F32 FSL SERIES
FSL-1M . . . . . . . . . . . .F32 FSL SERIES
FSL-2 . . . . . . . . . . . . . .F32 FSL SERIES
FSL-2M . . . . . . . . . . . .F32 FSL SERIES
FSLB-1 . . . . . . . . . . . . .F34 FSLB SERIES
FSLB-2 . . . . . . . . . . . . .F34 FSLB SERIES
FSOC-1 . . . . . . . . . . . . .F32 FSOC SERIES
FSPT . . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
FSQ . . . . . . . . . . . . .F38,39 FSQ SERIES
FSR-1 . . . . . . . . . . . . . .F33 FSR SERIES
FSR-1M . . . . . . . . . . . .F33 FSR SERIES
FSR-2 . . . . . . . . . . . . . .F33 FSR SERIES
FSR-2M . . . . . . . . . . . .F33 FSR SERIES
FSRG . . . . . . . . . . . . . . .F40 FS/FD SER DEV CVRS
FSS-1 . . . . . . . . . . . . . .F35 FSS SERIES
FSS-1M . . . . . . . . . . . .F35 FSS SERIES
FSS-2 . . . . . . . . . . . . . .F35 FSS SERIES
FSS-2M . . . . . . . . . . . .F35 FSS SERIES
FST . . . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
FST-1 . . . . . . . . . . . . . .F33 FST SERIES
FST-1M . . . . . . . . . . . . .F33 FST SERIES
FST-2 . . . . . . . . . . . . . .F33 FST SERIES
FST-2M . . . . . . . . . . . . .F33 FST SERIES
FSTG . . . . . . . . . . . . . . .F41 FS/FD SER DEV CVRS
FSX-1 . . . . . . . . . . . . . .F34 FSX SERIES
FSX-1M . . . . . . . . . . . .F34 FSX SERIES
FSX-2 . . . . . . . . . . . . . .F34 FSX SERIES
FSX-2M . . . . . . . . . . . .F34 FSX SERIES
FXB-1 . . . . . . . . . . . . . .C13 FXB SERIES
FXB-10 . . . . . . . . . . . . .C13 FXB SERIES
FXB-11 . . . . . . . . . . . . .C13 FXB SERIES
FXB-12 . . . . . . . . . . . . .C13 FXB SERIES
FXB-2 . . . . . . . . . . . . . .C13 FXB SERIES
FXB-3 . . . . . . . . . . . . . .C13 FXB SERIES
FXB-4 . . . . . . . . . . . . . .C13 FXB SERIES
FXB-5 . . . . . . . . . . . . . .C13 FXB SERIES
FXB-6 . . . . . . . . . . . . . .C13 FXB SERIES
FXB-7 . . . . . . . . . . . . . .C13 FXB SERIES
FXB-8 . . . . . . . . . . . . . .C13 FXB SERIES
FXB-9 . . . . . . . . . . . . . .C13 FXB SERIES
FXCS -2S3L6G . . . . . .C16 FXCS SERIES
FXCS-0A15 . . . . . . . . .C15 FXCS SERIES
FXCS-0B1 . . . . . . . . . .C14 FXCS SERIES
FXCS-0B13-C . . . . . . .C15 FXCS SERIES
FXCS-0B13-O . . . . . . .C15 FXCS SERIES
FXCS-0B13-U . . . . . . .C15 FXCS SERIES
FXCS-0B2 . . . . . . . . . .C14 FXCS SERIES
FXCS-0B24CL . . . . . . .C14 FXCS SERIES
FXCS-0B24GL . . . . . . .C14 FXCS SERIES
FXCS-0B24RL . . . . . . .C14 FXCS SERIES
FXCS-0B3 . . . . . . . . . .C14 FXCS SERIES
FXCS-0B30CL . . . . . . .C15 FXCS SERIES
FXCS-0B30GL . . . . . . .C15 FXCS SERIES
FXCS-0B30RL . . . . . . .C15 FXCS SERIES
FXCS-0B30RL-GL . . . .C15 FXCS SERIES
FXCS-0B4 . . . . . . . . . .C14 FXCS SERIES
FXCS-0B4U . . . . . . . . .C14 FXCS SERIES
FXCS-0B5 . . . . . . . . . .C14 FXCS SERIES
FXCS-0B7 . . . . . . . . . .C14 FXCS SERIES
FXCS-0K2A1 . . . . . . . .C16 FXCS SERIES
FXCS-0K2A5 . . . . . . . .C16 FXCS SERIES
FXCS-0K2L3F22D . . . .C16 FXCS SERIES
FXCS-0K3C4 . . . . . . . .C16 FXCS SERIES
FXCS-0K3C5 . . . . . . . .C16 FXCS SERIES
FXCS-0K3L6G32D . . .C16 FXCS SERIES
FXCS-0K3M6G32D . . .C16 FXCS SERIES
FXCS-0K3R6G32D . . .C16 FXCS SERIES
FXCS-0S2A1 . . . . . . . .C16 FXCS SERIES
FXCS-0S2A5 . . . . . . . .C16 FXCS SERIES
FXCS-0S2L3F . . . . . . .C16 FXCS SERIES
FXCS-0S3C4 . . . . . . . .C16 FXCS SERIES
FXCS-0S3C5 . . . . . . . .C16 FXCS SERIES
FXCS-0S3L6G . . . . . . .C16 FXCS SERIES
FXCS-0S3M6G . . . . . .C16 FXCS SERIES
FXCS-0S3R6G . . . . . . .C16 FXCS SERIES
FXCS-1A15 . . . . . . . . .C15 FXCS SERIES
FXCS-1B1 . . . . . . . . . .C14 FXCS SERIES
FXCS-1B13-0 . . . . . . .C15 FXCS SERIES
FXCS-1B13-C . . . . . . .C15 FXCS SERIES
FXCS-1B13-U . . . . . . .C15 FXCS SERIES
FXCS-1B2 . . . . . . . . . .C14 FXCS SERIES
FXCS-1B24-CL . . . . . .C14 FXCS SERIES
FXCS-1B24-GL . . . . . .C14 FXCS SERIES
FXCS-1B24-RL . . . . . .C14 FXCS SERIES
FXCS-1B3 . . . . . . . . . .C14 FXCS SERIES
FXCS-1B30-CL . . . . . .C15 FXCS SERIES
FXCS-1B30-GL . . . . . .C15 FXCS SERIES
FXCS-1B30-RL . . . . . .C15 FXCS SERIES
FXCS-1B30RL-GL . . . .C15 FXCS SERIES
FXCS-1B4 . . . . . . . . . .C14 FXCS SERIES
FXCS-1B4-U . . . . . . . .C14 FXCS SERIES
FXCS-1B5 . . . . . . . . . .C14 FXCS SERIES
FXCS-1B7 . . . . . . . . . .C14 FXCS SERIES
FXCS-1K2A1 . . . . . . . .C16 FXCS SERIES
FXCS-1K2A5 . . . . . . . .C16 FXCS SERIES
FXCS-1K2L3F22D . . . .C16 FXCS SERIES
FXCS-1K3C4 . . . . . . . .C16 FXCS SERIES
FXCS-1K3C5 . . . . . . . .C16 FXCS SERIES
FXCS-1K3L6G32D . . .C16 FXCS SERIES
FXCS-1K3M6G32D . . .C16 FXCS SERIES
FXCS-1K3R6G32D . . .C16 FXCS SERIES
FXCS-1S2A1 . . . . . . . .C16 FXCS SERIES
FXCS-1S2A5 . . . . . . . .C16 FXCS SERIES
FXCS-1S2L3F . . . . . . .C16 FXCS SERIES
FXCS-1S3C4 . . . . . . . .C16 FXCS SERIES
FXCS-1S3C5 . . . . . . . .C16 FXCS SERIES
FXCS-1S3L6G . . . . . . .C16 FXCS SERIES
FXCS-1S3M6G . . . . . .C16 FXCS SERIES
FXCS-1S3R6G . . . . . . .C16 FXCS SERIES
FXCS-2A15 . . . . . . . . .C15 FXCS SERIES
FXCS-2B1 . . . . . . . . . .C14 FXCS SERIES
FXCS-2B13-C . . . . . . .C15 FXCS SERIES
FXCS-2B13-O . . . . . . .C15 FXCS SERIES
FXCS-2B13-U . . . . . . .C15 FXCS SERIES
FXCS-2B2 . . . . . . . . . .C14 FXCS SERIES
FXCS-2B24-CL . . . . . .C14 FXCS SERIES
FXCS-2B24-GL . . . . . .C14 FXCS SERIES
FXCS-2B24-RL . . . . . .C14 FXCS SERIES
FXCS-2B3 . . . . . . . . . .C14 FXCS SERIES
FXCS-2B30-CL . . . . . .C15 FXCS SERIES
FXCS-2B30-GL . . . . . .C15 FXCS SERIES
FXCS-2B30-RL . . . . . .C15 FXCS SERIES
FXCS-2B30RL-GL . . . .C15 FXCS SERIES
FXCS-2B4 . . . . . . . . . .C14 FXCS SERIES
FXCS-2B4-U . . . . . . . .C14 FXCS SERIES
FXCS-2B5 . . . . . . . . . .C14 FXCS SERIES
FXCS-2B7 . . . . . . . . . .C14 FXCS SERIES
FXCS-2K2A1 . . . . . . . .C16 FXCS SERIES
FXCS-2K2A5 . . . . . . . .C16 FXCS SERIES
FXCS-2K2L3F22D . . . .C16 FXCS SERIES
FXCS-2K3C4 . . . . . . . .C16 FXCS SERIES
FXCS-2K3C5 . . . . . . . .C16 FXCS SERIES
FXCS-2K3L6G32D . . .C16 FXCS SERIES
FXCS-2K3M6G32D . . .C16 FXCS SERIES
FXCS-2K3R6G32D . . .C16 FXCS SERIES
FXCS-2S2A1 . . . . . . . .C16 FXCS SERIES
FXCS-2S2A5 . . . . . . . .C16 FXCS SERIES
FXCS-2S2L3F . . . . . . .C16 FXCS SERIES
FXCS-2S3C4 . . . . . . . .C16 FXCS SERIES
FXCS-2S3C5 . . . . . . . .C16 FXCS SERIES
FXCS-2S3M6G . . . . . .C16 FXCS SERIES
FXCS-2S3R6G . . . . . . .C16 FXCS SERIES
FXCS-4A15 . . . . . . . . .C15 FXCS SERIES
FXCS-4B1 . . . . . . . . . .C14 FXCS SERIES
FXCS-4B13-C . . . . . . .C15 FXCS SERIES
FXCS-4B13-O . . . . . . .C15 FXCS SERIES
FXCS-4B13-U . . . . . . .C15 FXCS SERIES
FXCS-4B2 . . . . . . . . . .C14 FXCS SERIES
FXCS-4B24-CL . . . . . .C14 FXCS SERIES
FXCS-4B24-GL . . . . . .C14 FXCS SERIES
FXCS-4B24-RL . . . . . .C14 FXCS SERIES
FXCS-4B3 . . . . . . . . . .C14 FXCS SERIES
FXCS-4B30-CL . . . . . .C15 FXCS SERIES
FXCS-4B30-GL . . . . . .C15 FXCS SERIES
FXCS-4B30-RL . . . . . .C15 FXCS SERIES
FXCS-4B30RL-GL . . . .C15 FXCS SERIES
FXCS-4B4 . . . . . . . . . .C14 FXCS SERIES
FXCS-4B4-U . . . . . . . .C14 FXCS SERIES
FXCS-4B5 . . . . . . . . . .C14 FXCS SERIES
FXCS-4B7 . . . . . . . . . .C14 FXCS SERIES
FXCS-4K2A1 . . . . . . . .C16 FXCS SERIES
FXCS-4K2A5 . . . . . . . .C16 FXCS SERIES
FXCS-4K2L3F22D . .C16 FXCS SERIES
FXCS-4K3C4 . . . . . . . .C16 FXCS SERIES
FXCS-4K3C5 . . . . . . . .C16 FXCS SERIES
FXCS-4K3L6G32D . .C16 FXCS SERIES
FXCS-4K3M6G32D . .C16 FXCS SERIES
FXCS-4K3R6G32D . . C16 FXCS SERIES
FXCS-4S2A1 . . . . . . . .C16 FXCS SERIES
FXCS-4S2A5 . . . . . . . .C16 FXCS SERIES
FXCS-4S2L3F . . . . . . .C16 FXCS SERIES
FXCS-4S3C4 . . . . . . . .C16 FXCS SERIES
FXCS-4S3C5 . . . . . . . .C16 FXCS SERIES
FXCS-4S3L6G . . . . . . .C16 FXCS SERIES
FXCS-4S3M6G . . . . . .C16 FXCS SERIES
FXCS-4S3R6G . . . . . . .C16 FXCS SERIES
FXCS-5A15 . . . . . . . . .C15 FXCS SERIES
FXCS-5B1 . . . . . . . . . .C14 FXCS SERIES
FXCS-5B13-C . . . . . . .C15 FXCS SERIES
FXCS-5B13-O . . . . . . .C15 FXCS SERIES
FXCS-5B13-U . . . . . . .C15 FXCS SERIES
FXCS-5B2 . . . . . . . . . .C14 FXCS SERIES
FXCS-5B24-CL . . . . . .C14 FXCS SERIES
FXCS-5B24-GL . . . . . .C14 FXCS SERIES
FXCS-5B24-RL . . . . . .C14 FXCS SERIES
FXCS-5B3 . . . . . . . . . .C14 FXCS SERIES
FXCS-5B30-CL . . . . . .C15 FXCS SERIES
FXCS-5B30-GL . . . . . .C15 FXCS SERIES
FXCS-5B30-RL . . . . . .C15 FXCS SERIES
FXCS-5B30RL-GL . . . .C15 FXCS SERIES
FXCS-5B4 . . . . . . . . . .C14 FXCS SERIES
FXCS-5B4-U . . . . . . . .C14 FXCS SERIES
FXCS-5B5 . . . . . . . . . .C14 FXCS SERIES
FXCS-5B7 . . . . . . . . . .C14 FXCS SERIES
FXCS-5K2A1 . . . . . . . .C16 FXCS SERIES
FXCS-5K2A5 . . . . . . . .C16 FXCS SERIES
FXCS-5K2L3F22D . .C16 FXCS SERIES
FXCS-5K3C4 . . . . . . . .C16 FXCS SERIES
FXCS-5K3C5 . . . . . . . .C16 FXCS SERIES
FXCS-5K3L6G32D .C16 FXCS SERIES
FXCS-5K3M6G32D . C16 FXCS SERIES
FXCS-5K3R6G32D . C16 FXCS SERIES
FXCS-5S2A1 . . . . . . . .C16 FXCS SERIES
FXCS-5S2A5 . . . . . . . .C16 FXCS SERIES
FXCS-5S2L3F . . . . . . .C16 FXCS SERIES
FXCS-5S3C4 . . . . . . . .C16 FXCS SERIES
FXCS-5S3C5 . . . . . . . .C16 FXCS SERIES
FXCS-5S3L6G . . . . . . .C16 FXCS SERIES
FXCS-5S3M6G . . . . . .C16 FXCS SERIES
FXCS-5S3R6G . . . . . . .C16 FXCS SERIES
FXCS-OMMG3 . . . . . .C15 FXCS SERIES
FXCS-OMMK3 . . . . . . .C15 FXCS SERIES
FXCS-OMMR3 . . .C15,27 FXCS SERIES
FXCS-OMMR3-LOM . .C15 FXCS SERIES
FXS-11C . . . . . . . . . . .C17 FXS SERIES
FXS-11D . . . . . . . . . . .C17 FXS SERIES
FXS-12C . . . . . . . . . . .C17 FXS SERIES
FXS-12D . . . . . . . . . . .C17 FXS SERIES
FXS-13C . . . . . . . . . . .C17 FXS SERIES
FXS-15C . . . . . . . . . . .C17 FXS SERIES
FXS-16C . . . . . . . . . . .C17 FXS SERIES
FXS-18C . . . . . . . . . . .C17 FXS SERIES
FXS-1C . . . . . . . . . . . .C17 FXS SERIES
FXS-1D . . . . . . . . . . . .C17 FXS SERIES
FXS-21C . . . . . . . . . . .C17 FXS SERIES
FXS-21D . . . . . . . . . . .C17 FXS SERIES
FXS-22C . . . . . . . . . . .C17 FXS SERIES
FXS-22D . . . . . . . . . . .C17 FXS SERIES
FXS-23C . . . . . . . . . . .C17 FXS SERIES
FXS-25C . . . . . . . . . . .C17 FXS SERIES
FXS-26C . . . . . . . . . . .C17 FXS SERIES
FXS-28C . . . . . . . . . . .C17 FXS SERIES
FXS-2C . . . . . . . . . . . .C17 FXS SERIES
FXS-2D . . . . . . . . . . . .C17 FXS SERIES
FXS-3C . . . . . . . . . . . .C17 FXS SERIES
FXS-41C . . . . . . . . . . .C17 FXS SERIES
FXS-41D . . . . . . . . . . .C17 FXS SERIES
FXS-42C . . . . . . . . . . .C17 FXS SERIES
FXS-42D . . . . . . . . . . .C17 FXS SERIES
FXS-43C . . . . . . . . . . .C17 FXS SERIES
FXS-45C . . . . . . . . . . .C17 FXS SERIES
FXS-46C . . . . . . . . . . .C17 FXS SERIES
FXS-48C . . . . . . . . . . .C17 FXS SERIES
FXS-4C . . . . . . . . . . . .C17 FXS SERIES
FXS-51C . . . . . . . . . . .C17 FXS SERIES
FXS-51D . . . . . . . . . . .C17 FXS SERIES
FXS-52C . . . . . . . . . . .C17 FXS SERIES
FXS-52D . . . . . . . . . . .C17 FXS SERIES
FXS-53C . . . . . . . . . . .C17 FXS SERIES
FXS-55C . . . . . . . . . . .C17 FXS SERIES
FXS-56C . . . . . . . . . . .C17 FXS SERIES
FXS-58C . . . . . . . . . . .C17 FXS SERIES
FXS-5C . . . . . . . . . . . .C17 FXS SERIES
FXS-6C . . . . . . . . . . . .C17 FXS SERIES
FXS-8C . . . . . . . . . . . .C17 FXS SERIES
FXSD01 . . . . . . . . . . . .C53 FXS SERIES
FXSD02 . . . . . . . . . . . .C53 FXS SERIES
FXSD11 . . . . . . . . . . . .C53 FXS SERIES
FXSD12 . . . . . . . . . . . .C53 FXS SERIES
FXSD21 . . . . . . . . . . . .C53 FXS SERIES
FXSD22 . . . . . . . . . . . .C53 FXS SERIES
FXSD41 . . . . . . . . . . . .C53 FXS SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
INTRODUCTION
NUMERIC INDEX
N4
INTRODUCTION
NUMERIC INDEX N5
FXSD42 . . . . . . . . . . . .C53 FXS SERIES
FXSD51 . . . . . . . . . . . .C53 FXS SERIES
FXSD52 . . . . . . . . . . . .C53 FXS SERIES
FXS-GFI-1020 . . . . . . .C17 FXS SERIES
FXS-GFI-1120 . . . . . . .C17 FXS SERIES
FXS-GFI-2020 . . . . . . .C17 FXS SERIES
FXS-GFI-2120 . . . . . . .C17 FXS SERIES
FXS-GFI-3020 . . . . . . .C17 FXS SERIES
FXS-GFI-3120 . . . . . . .C17 FXS SERIES
FXS-GFIO3 . . . . . . . . . .C17 FXS SERIES
FXS-GFIO3PL . . . . . . .C17 FXS SERIES
FXSX02 . . . . . . . . . . . .C53 FXS SERIES
FXSX03 . . . . . . . . . . . .C53 FXS SERIES
FXSX12 . . . . . . . . . . . .C53 FXS SERIES
FXSX13 . . . . . . . . . . . .C53 FXS SERIES
FXSX22 . . . . . . . . . . . .C53 FXS SERIES
FXSX23 . . . . . . . . . . . .C53 FXS SERIES
FXSX42 . . . . . . . . . . . .C53 FXS SERIES
FXSX43 . . . . . . . . . . . .C53 FXS SERIES
FXSX52 . . . . . . . . . . . .C53 FXS SERIES
FXSX53 . . . . . . . . . . . .C53 FXS SERIES
FZ . . . . . . . . . . . . . . . . .F42 FS/FD SER DEV CVRS
FZ8647 . . . . . . . . . .F41,42 FS/FD SER DEV CVRS
FZ8648 . . . . . . . . . .F41,42 FS/FD SER DEV CVRS
G0-567-LOK . . . . . . . .C26 GO SERIES
GASK571 . . . . . . . . . . . .F9 DURALOY 7 SERIES
GASK572 . . . . . . . . . . . .F9 DURALOY 7 SERIES
GASK573 . . . . . . . . . . . .F9 DURALOY 7 SERIES
GASK574 . . . . . . . . . . . .F9 DURALOY 7 SERIES
GASK575 . . . . . . . . . . . .F9 DURALOY 7 SERIES
GASK576 . . . . . . . . . . . .F9 DURALOY 7 SERIES
GASK578 . . . . . . . . . . . .F9 DURALOY 7 SERIES
GASK579 . . . . . . . . . . . .F9 DURALOY 7 SERIES
GASK805N . . . . . . . . . .F14 DURALOY 8 SERIES
GASK806N . . . . . . . . . .F14 DURALOY 8 SERIES
GASK808N . . . . . . . . . .F14 DURALOY 8 SERIES
GASK809N . . . . . . . . . .F14 DURALOY 8 SERIES
GASK851N . . . . . . . . . .F14 DURALOY 8 SERIES
GASK852N . . . . . . . . . .F14 DURALOY 8 SERIES
GASK853N . . . . . . . . . .F14 DURALOY 8 SERIES
GASK854N . . . . . . . . . .F14 DURALOY 8 SERIES
GCBB-15Q1 . . . . . . . .DE24 GCBB SERIES
GCBB-15Q2 . . . . . . . .DE24 GCBB SERIES
GCBB-15Q3 . . . . . . . .DE24 GCBB SERIES
GCBB-1Q . . . . . . . . . .DE24 GCBB SERIES
GCBB-1Q . . . . . . . . . .DE24 GCBB SERIES
GCBB-20Q1 . . . . . . . .DE24 GCBB SERIES
GCBB-20Q2 . . . . . . . .DE24 GCBB SERIES
GCBB-20Q3 . . . . . . . .DE24 GCBB SERIES
GCBB-2Q . . . . . . . . . .DE24 GCBB SERIES
GCBB-2Q . . . . . . . . . .DE24 GCBB SERIES
GCBB-30Q1 . . . . . . . .DE24 GCBB SERIES
GCBB-30Q2 . . . . . . . .DE24 GCBB SERIES
GCBB-30Q3 . . . . . . . .DE24 GCBB SERIES
GCBB-40Q1 . . . . . . . .DE24 GCBB SERIES
GCBB-40Q2 . . . . . . . .DE24 GCBB SERIES
GCBB-40Q3 . . . . . . . .DE24 GCBB SERIES
GCS-13 . . . . . . . . . . . .C37 GCS SERIES
GCS-131 . . . . . . . . . . .C37 GCS SERIES
GCS-14 . . . . . . . . . . . .C37 GCS SERIES
GCS-141 . . . . . . . . . . .C37 GCS SERIES
GCS-15 . . . . . . . . . . . .C37 GCS SERIES
GCS-152 . . . . . . . . . . .C37 GCS SERIES
GCS-16 . . . . . . . . . . . .C37 GCS SERIES
GCS-163 . . . . . . . . . . .C37 GCS SERIES
GCS-83 . . . . . . . . . . . .C37 GCS SERIES
GCS-834 . . . . . . . . . . .C37 GCS SERIES
GCS-835 . . . . . . . . . . .C37 GCS SERIES
GCS-85 . . . . . . . . . . . .C37 GCS SERIES
GEBC-2 . . . . . . . . . . . . .F49 GEB SERIES
GEBC-3 . . . . . . . . . . . . .F49 GEB SERIES
GEBC-4 . . . . . . . . . . . . .F49 GEB SERIES
GEBC-5 . . . . . . . . . . . . .F49 GEB SERIES
GEBL-2 . . . . . . . . . . . . .F49 GEB SERIES
GEBL-3 . . . . . . . . . . . . .F49 GEB SERIES
GEBL-4 . . . . . . . . . . . . .F49 GEB SERIES
GEBL-5 . . . . . . . . . . . . .F49 GEB SERIES
GEBT-2 . . . . . . . . . . . . .F50 GEB SERIES
GEBT-24 . . . . . . . . . . . .F50 GEB SERIES
GEBT-25 . . . . . . . . . . . .F50 GEB SERIES
GEBT-3 . . . . . . . . . . . . .F50 GEB SERIES
GEBT-4 . . . . . . . . . . . . .F50 GEB SERIES
GEBT-5 . . . . . . . . . . . . .F50 GEB SERIES
GEBX-2 . . . . . . . . . . . . .F50 GEB SERIES
GEBX-3 . . . . . . . . . . . . .F50 GEB SERIES
GEBX-4 . . . . . . . . . . . . .F50 GEB SERIES
GEBX-5 . . . . . . . . . . . . .F50 GEB SERIES
GECBC . . . . . . . . . . . . .F56 GE SERIES ACC
GECCAT-1 . . . . . . . . . . .F54 GE SERIES
GECCAT-1M . . . . . . . . .F54 GE SERIES
GECCT-1 . . . . . . . . . . . .F52 GE SERIES
GECCT-1M . . . . . . . . . .F52 GE SERIES
GECCT-2 . . . . . . . . . . . .F52 GE SERIES
GECCT-2-6TB . . . . . . . . .E7 GE SERIES
GECCT-2M . . . . . . . . . .F52 GE SERIES
GECCT-3 . . . . . . . . . . . .F52 GE SERIES
GECCT-3M . . . . . . . . . .F52 GE SERIES
GECEAT-2 . . . . . . . . . . .F54 GE SERIES
GECEAT-2M . . . . . . . . .F54 GE SERIES
GECET-1 . . . . . . . . . . . .F51 GE SERIES
GECET-1M . . . . . . . . . .F51 GE SERIES
GECET-2 . . . . . . . . . . . .F51 GE SERIES
GECET-2M . . . . . . . . . .F51 GE SERIES
GECET-3 . . . . . . . . . . . .F51 GE SERIES
GECET-3M . . . . . . . . . .F51 GE SERIES
GECEY . . . . . . . . . . . . .F56 GE SERIES ACC
GECLBT-1 . . . . . . . . . . .F53 GE SERIES
GECLBT-1M . . . . . . . . .F53 GE SERIES
GECLBT-2 . . . . . . . . . . .F53 GE SERIES
GECLBT-2M . . . . . . . . .F53 GE SERIES
GECLBT-3 . . . . . . . . . . .F53 GE SERIES
GECLBT-3M . . . . . . . . .F53 GE SERIES
GECLT-1 . . . . . . . . . . . .F52 GE SERIES
GECLT-1M . . . . . . . . . .F52 GE SERIES
GECLT-2 . . . . . . . . . . . .F52 GE SERIES
GECLT-2M . . . . . . . . . .F52 GE SERIES
GECLT-3 . . . . . . . . . . . .F52 GE SERIES
GECLT-3M . . . . . . . . . .F52 GE SERIES
GEC-RG . . . . . . .F56,57,58 GE SERIES
GECTAT-2 . . . . . . . . . . .F54 GE SERIES
GECTAT-2M . . . . . . . . .F54 GE SERIES
GECTT-1 . . . . . . . . . . . .F53 GE SERIES
GECTT-1M . . . . . . . . . .F53 GE SERIES
GECTT-2 . . . . . . . . . . . .F53 GE SERIES
GECTT-2-6TB . . . . . . . . .E7 GE SERIES
GECTT-2M . . . . . . . . . .F53 GE SERIES
GECTT-3 . . . . . . . . . . . .F53 GE SERIES
GECTT-3M . . . . . . . . . .F53 GE SERIES
GECUET-2 . . . . . . . . . . .F55 GE SERIES
GECUET-2M . . . . . . . . .F55 GE SERIES
GECUWT-2 . . . . . . . . . .F55 GE SERIES
GECUWT-2M . . . . . . . .F55 GE SERIES
GECXAT-1 . . . . . . . . . . .F54 GE SERIES
GECXAT-1M . . . . . . . . .F54 GE SERIES
GECXAT-2 . . . . . . . . . . .F54 GE SERIES
GECXAT-2M . . . . . . . . .F54 GE SERIES
GECXAT-3 . . . . . . . . . . .F54 GE SERIES
GECXAT-3M . . . . . . . . .F54 GE SERIES
GECXT-1 . . . . . . . . . . . .F53 GE SERIES
GECXT-1M . . . . . . . . . .F53 GE SERIES
GECXT-2 . . . . . . . . . . . .F53 GE SERIES
GECXT-2-6TB . . . . . . . . .E7 GE SERIES
GECXT-2M . . . . . . . . . .F53 GE SERIES
GECXT-3 . . . . . . . . . . . .F53 GE SERIES
GECXT-3M . . . . . . . . . .F53 GE SERIES
GECXTF-1 . . . . . . . . . . .F55 GE SERIES
GECXTF-1M . . . . . . . . .F55 GE SERIES
GECXTF-2 . . . . . . . . . . .F55 GE SERIES
GECXTF-2-6TB . . . . . . . .E7 GE SERIES
GECXTF-2M . . . . . . . . .F55 GE SERIES
GECXTF-3 . . . . . . . . . . .F55 GE SERIES
GECXTF-3M . . . . . . . . .F55 GE SERIES
GEJCT-5 . . . . . . . . . . . .F52 GE SERIES
GEJCT-5M . . . . . . . . . .F52 GE SERIES
GEJCT-6 . . . . . . . . . . . .F52 GE SERIES
GEJCT-6M . . . . . . . . . .F52 GE SERIES
GEJET-5 . . . . . . . . . . . .F51 GE SERIES
GEJET-5M . . . . . . . . . . .F51 GE SERIES
GEJEY . . . . . . . . . . . . . .F56 GE SERIES ACC
GEJLBT-5 . . . . . . . . . . .F53 GE SERIES
GEJLBT-5M . . . . . . . . .F53 GE SERIES
GEJLBT-6 . . . . . . . . . . .F53 GE SERIES
GEJLBT-6M . . . . . . . . .F53 GE SERIES
GEJLT-5 . . . . . . . . . . . .F52 GE SERIES
GEJLT-5M . . . . . . . . . . .F52 GE SERIES
GEJLT-6 . . . . . . . . . . . .F52 GE SERIES
GEJLT-6M . . . . . . . . . . .F52 GE SERIES
GEJTT-5 . . . . . . . . . . . .F53 GE SERIES
GEJTT-5M . . . . . . . . . . .F53 GE SERIES
GEJTT-6 . . . . . . . . . . . .F53 GE SERIES
GEJTT-6M . . . . . . . . . . .F53 GE SERIES
GEJXT-5 . . . . . . . . . . . .F53 GE SERIES
GEJXT-5M . . . . . . . . . .F53 GE SERIES
GEJXT-6 . . . . . . . . . . . .F53 GE SERIES
GEJXT-6M . . . . . . . . . .F53 GE SERIES
GEMBC . . . . . . . . . . . . .F56 GE SERIES ACC
GEMC-1 . . . . . . . . . . . .F52 GE SERIES
GEMC-2 . . . . . . . . . . . .F52 GE SERIES
GEMCA-1 . . . . . . . . . . .F54 GE SERIES
GEMCA-2 . . . . . . . . . . .F54 GE SERIES
GEMEY . . . . . . . . . . . . .F56 GE SERIES ACC
GEML-1 . . . . . . . . . . . .F52 GE SERIES
GEML-2 . . . . . . . . . . . .F52 GE SERIES
GEMLA-1 . . . . . . . . . . .F54 GE SERIES
GEMLA-2 . . . . . . . . . . .F54 GE SERIES
GEMLB-1 . . . . . . . . . . .F53 GE SERIES
GEMLB-2 . . . . . . . . . . .F53 GE SERIES
GEM-RG . . . . . . . . . . . .F56 GE SERIES ACC
GEMT-1 . . . . . . . . . . . .F53 GE SERIES
GEMT-2 . . . . . . . . . . . .F53 GE SERIES
GEMTA-1 . . . . . . . . . . .F54 GE SERIES
GEMTA-2 . . . . . . . . . . .F54 GE SERIES
GEMX-1 . . . . . . . . . . . .F53 GE SERIES
GEMX-2 . . . . . . . . . . . .F53 GE SERIES
GESBC . . . . . . . . . . . . .F56 GE SERIES ACC
GESCAT-4 . . . . . . . . . . .F54 GE SERIES
GESCAT-4M . . . . . . . . .F54 GE SERIES
GESCT-3 . . . . . . . . . . . .F52 GE SERIES
GESCT-3M . . . . . . . . . .F52 GE SERIES
GESCT-4 . . . . . . . . . . . .F52 GE SERIES
GESCT-4M . . . . . . . . . .F52 GE SERIES
GESEY . . . . . . . . . . . . . .F56 GE SERIES ACC
GESLBT-3 . . . . . . . . . . .F53 GE SERIES
GESLBT-3M . . . . . . . . .F53 GE SERIES
GESLBT-4 . . . . . . . . . . .F53 GE SERIES
GESLBT-4M . . . . . . . . .F53 GE SERIES
GESLT-3 . . . . . . . . . . . .F52 GE SERIES
GESLT-3M . . . . . . . . . .F52 GE SERIES
GESLT-4 . . . . . . . . . . . .F52 GE SERIES
GESLT-4M . . . . . . . . . .F52 GE SERIES
GES-RG . . . . . . . . . . . .F56 GE SERIES ACC
GESTT-3 . . . . . . . . . . . .F53 GE SERIES
GESTT-3M . . . . . . . . . .F53 GE SERIES
GESTT-4 . . . . . . . . . . . .F53 GE SERIES
GESTT-4M . . . . . . . . . .F53 GE SERIES
GESXAT-4 . . . . . . . . . . .F54 GE SERIES
GESXAT-4M . . . . . . . . .F54 GE SERIES
GESXT-3 . . . . . . . . . . . .F53 GE SERIES
GESXT-3M . . . . . . . . . .F53 GE SERIES
GESXT-4 . . . . . . . . . . . .F53 GE SERIES
GESXT-4M . . . . . . . . . .F53 GE SERIES
GEUEAT-2 . . . . . . . . . . .F55 GE SERIES
GEUEAT-2M . . . . . . . . .F55 GE SERIES
GFCS05151 . . . . . . . .DE25 GFCS SEREIS
GFCS05152 . . . . . . . .DE25 GFCS SEREIS
GFCS05201 . . . . . . . .DE25 GFCS SEREIS
GFCS05202 . . . . . . . .DE25 GFCS SEREIS
GFCS05301 . . . . . . . .DE25 GFCS SEREIS
GFCS05302 . . . . . . . .DE25 GFCS SEREIS
GFCS30151 . . . . . . . .DE25 GFCS SEREIS
GFCS30152 . . . . . . . .DE25 GFCS SEREIS
GFCS30201 . . . . . . . .DE25 GFCS SEREIS
GFCS30202 . . . . . . . .DE25 GFCS SEREIS
GFCS30301 . . . . . . . .DE25 GFCS SEREIS
GFCS30302 . . . . . . . .DE25 GFCS SEREIS
GL-275 . . . . . . . . . .E18,25 GR SERIES
GL-300 . . . . . . . . . .E18,25 GR SERIES
GL-375 . . . . . . . . . . . . .F56 GR SERIES
GL-537 . . . . . . . . . .E18,25 GR SERIES
GL-600 . . . . . . . . . .E18,25 GR SERIES
GL-775 . . . . . . . . . .E18,25 GR SERIES
GLX-275 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLX-300 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLX-375 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLX-537 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLX-600 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLX-775 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLXR13 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLXR24 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLXR27 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLXR34 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLXR36 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLXR47 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLXR59 . . . . . . . . . . . .E18 ENCLOSURE ACC
GLXR99 . . . . . . . . . . . .E18 ENCLOSURE ACC
GO10-31F N34 . . . . . .C36 GO SERIES
GO10-33F N34 . . . . . .C36 GO SERIES
GO-10502 . . . . . . . . . .C38 GO SERIES
GO113 N34 . . . . . . . . .C36 GO SERIES
GO-11372-093 . . . . . .C36 GO SERIES
GO-11388-078 . . . . . .C36 GO SERIES
GO114 N34 . . . . . . . . .C36 GO SERIES
GO133 . . . . . . . . . . . . .C36 GO SERIES
GO134 . . . . . . . . . . . . .C36 GO SERIES
GO14-0G N34 . . . . . . .C34 GO SERIES
GO14-6G N34 . . . . . . .C34 GO SERIES
GO15-0G N34 . . . . . . .C34 GO SERIES
GO15-6G N34 . . . . . . .C34 GO SERIES
GO15726-A . . . . . . . . .C38 GO SERIES
GO15726-B . . . . . . . . .C38 GO SERIES
GO15726-C . . . . . . . . .C38 GO SERIES
GO15726-F . . . . . . . . .C38 GO SERIES
GO15726-G . . . . . . . . .C38 GO SERIES
GO15726-R . . . . . . . . .C38 GO SERIES
GO16 . . . . . . . . . . . . . .C36 GO SERIES
GO17 . . . . . . . . . . . . . .C36 GO SERIES
GO18 . . . . . . . . . . . . . .C36 GO SERIES
GO19 . . . . . . . . . . . . . .C36 GO SERIES
GO1-GX0C N34 . . . . . .C31 GO SERIES
GO1-GX1B N34 . . . . . .C31 GO SERIES
GO1-GX3C N34 . . . . . .C31 GO SERIES
GO1-KX0C N34 . . . . . .C31 GO SERIES
GO1-KX1C N34 . . . . . .C31 GO SERIES
GO1-KX2C N34 . . . . . .C31 GO SERIES
GO1-KX3C N34 . . . . . .C31 GO SERIES
GO1-RX0C N34 . . . . . .C31 GO SERIES
GO1-RX2B N34 . . . . . .C31 GO SERIES
GO1-RX3C N34 . . . . . .C31 GO SERIES
GO21-GZ0C . . . . . . . . .C31 GO SERIES
GO21-GZ1B . . . . . . . . .C31 GO SERIES
GO21-GZ3C . . . . . . . . .C31 GO SERIES
GO21-KZ0C . . . . . . . . .C31 GO SERIES
GO21-KZ1C . . . . . . . . .C31 GO SERIES
GO21-KZ2C . . . . . . . . .C31 GO SERIES
GO21-KZ3C . . . . . . . . .C31 GO SERIES
GO21-RZ0C . . . . . . . . .C31 GO SERIES
GO21-RZ2B . . . . . . . . .C31 GO SERIES
GO21-RZ3C . . . . . . . . .C31 GO SERIES
GO22-GR00D . . . . . . . .C31 GO SERIES
GO22-GR12D . . . . . . . .C31 GO SERIES
GO22-GR33D . . . . . . . .C31 GO SERIES
GO22-KK00D . . . . . . . .C31 GO SERIES
GO22-KK12D . . . . . . . .C31 GO SERIES
GO22-KK33D . . . . . . . .C31 GO SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
INTRODUCTION
NUMERIC INDEX
N6
GO23-A23C . . . . . . . . .C32 GO SERIES
GO23-B23C . . . . . . . . .C32 GO SERIES
GO23-C23C . . . . . . . . .C32 GO SERIES
GO23-F23C . . . . . . . . .C32 GO SERIES
GO23-G23C . . . . . . . . .C32 GO SERIES
GO23-R23C . . . . . . . . .C32 GO SERIES
GO25-2A0F . . . . . . . . .C34 GO SERIES
GO25-2A3F . . . . . . . . .C34 GO SERIES
GO25-3C0G . . . . . . . . .C34 GO SERIES
GO25-3C3G . . . . . . . . .C34 GO SERIES
GO25-4H0H . . . . . . . . .C34 GO SERIES
GO25-4H8H . . . . . . . . .C34 GO SERIES
GO26-0F . . . . . . . . . . .C34 GO SERIES
GO26-3F . . . . . . . . . . .C34 GO SERIES
GO27-0G . . . . . . . . . . .C34 GO SERIES
GO27-6G . . . . . . . . . . .C34 GO SERIES
GO28-2A0F22D . . . . . .C35 GO SERIES
GO28-2A3F22D . . . . . .C35 GO SERIES
GO28-3C0G32D . . . . .C35 GO SERIES
GO28-3C3G32D . . . . .C35 GO SERIES
GO2-GR00D N34 . . . . .C31 GO SERIES
GO2-GR12D N34 . . . . .C31 GO SERIES
GO2-GR33D N34 . . . . .C31 GO SERIES
GO2-KK00D N34 . . . . .C31 GO SERIES
GO2-KK12D N34 . . . . .C31 GO SERIES
GO2-KK33D N34 . . . . .C31 GO SERIES
GO30-31F . . . . . . . . . .C36 GO SERIES
GO30-33F . . . . . . . . . .C36 GO SERIES
GO34-0G . . . . . . . . . . .C34 GO SERIES
GO34-6G . . . . . . . . . . .C34 GO SERIES
GO35-0G . . . . . . . . . . .C34 GO SERIES
GO35-6G . . . . . . . . . . .C34 GO SERIES
GO36-2L0F22D N34 . .C35 GO SERIES
GO36-2L3F22D N34 . .C35 GO SERIES
GO37-3C0G32D N34 .C35 GO SERIES
GO37-3C6G32D N34 .C35 GO SERIES
GO38-3L0G32D N34 . .C35 GO SERIES
GO38-3L6G32D N34 . .C35 GO SERIES
GO39-3R0G32D N34 . .C35 GO SERIES
GO39-3R6G32D N34 . .C35 GO SERIES
GO40-KX2C . . . . . . . . .C36 GO SERIES
GO50 . . . . . . . . . . . . . .C36 GO SERIES
GO-51 . . . . . . . . . . . . . .C36 GO SERIES
GO5-2A0F N34 . . . . . .C34 GO SERIES
GO5-2A3F N34 . . . . . .C34 GO SERIES
GO5-3C0G N34 . . . . . .C34 GO SERIES
GO5-3C3G N34 . . . . . .C34 GO SERIES
GO5-4H0H N34 . . . . . .C34 GO SERIES
GO5-4H8H N34 . . . . . .C34 GO SERIES
GO56-2L0F22D . . . . . .C35 GO SERIES
GO56-2L3F22D . . . . . .C35 GO SERIES
GO567-LOK . . . . . . . . .C38 GO SERIES
GO57-3C0G32D . . . . .C35 GO SERIES
GO57-3C6G32D . . . . .C35 GO SERIES
GO58-3L0G32D . . . . . .C35 GO SERIES
GO58-3L6G32D . . . . . .C35 GO SERIES
GO59-3R0G32D . . . . . .C35 GO SERIES
GO59-3R6G32D . . . . . .C35 GO SERIES
GO6-0F N34 . . . . . . . . .C34 GO SERIES
GO6-3F N34 . . . . . . . . .C34 GO SERIES
GO7-0G N34 . . . . . . . .C34 GO SERIES
GO7-6G N34 . . . . . . . .C34 GO SERIES
GO-8176-1 . . . . . . . . . .C38 GO SERIES
GO-8176-2 . . . . . . . . . .C38 GO SERIES
GO-8176-3 . . . . . . . . . .C38 GO SERIES
GO-8177 . . . . . . . . . . .C38 GO SERIES
GO-8222 . . . . . . . . . . .C38 GO SERIES
GO8-2A0F22D N34 . . .C35 GO SERIES
GO8-2A3F22D N34 . . .C35 GO SERIES
GO8-3C0G32D N34 . .C35 GO SERIES
GO8-3C3G32D N34 . .C35 GO SERIES
GO-8665 . . . . . . . . . . .C38 GO SERIES
GO-8668-120 . . . . . . . .C39 GO SERIES
GO-8668-24 . . . . . . . . .C39 GO SERIES
GO-8670-32 . . . . . . . . .C38 GO SERIES
GO-8670-34 . . . . . . . . .C38 GO SERIES
GO-8671-42 . . . . . . . . .C38 GO SERIES
GO-8671-44 . . . . . . . . .C38 GO SERIES
GO-8672-BJE . . . . .C27,39 X/XCS SERIES
GO-8672-BJH . . . . .C27,39 X/XCS SERIES
GO-8672-BJJ . . . . .C27,39 X/XCS SERIES
GO-8672-BJK . . . . .C27,39 X/XCS SERIES
GO-8672-PTCC . . . . . .C27 X/XCS SERIES
GO-8672-PTCH . . . . . .C27 X/XCS SERIES
GO-9824 . . . . . . . . . . .C38 GO SERIES
GOB3-A23C N34 . . . . .C32 GO SERIES
GOB3-A23C N34 LED .C32 GO SERIES
GOB3-A23C N34CN . .C33 GO SERIES
GOB3-A23C N34LEDCNC33 GO SERIES
GOB3-B23C N34 . . . . .C32 GO SERIES
GOB3-B23C N34CN . .C33 GO SERIES
GOB3-C23C N34 . . . . .C32 GO SERIES
GOB3-C23C N34CN . .C33 GO SERIES
GOB3-F23C N34 . . . . .C32 GO SERIES
GOB3-F23C N34CN . .C33 GO SERIES
GOB3-G23C N34 . . . . .C32 GO SERIES
GOB3-G23C N34 LED .C32 GO SERIES
GOB3-G23C N34CN . .C33 GO SERIES
GOB3-G23C N34LEDCNC33 GO SERIES
GOB3-R23C N34 . . . . .C32 GO SERIES
GOB3-R23C N34 LED .C32 GO SERIES
GOB3-R23C N34CN . .C33 GO SERIES
GOB3-R23C N34LEDCN .C33 GO SERIES
GOB4-A230C N34 . . . .C32 GO SERIES
GOB4-A230C N34 LED .C32 GO SERIES
GOB4-A230CN34CN . .C33 GO SERIES
GOB4-A230CN34LEDCNC33 GO SERIES
GOB4-A233C N34 . . . .C32 GO SERIES
GOB4-A233C N34 LED .C32 GO SERIES
GOB4-A233CN34CN . .C33 GO SERIES
GOB4-A233CN34LEDCN C33 GO SERIES
GOB4-B230C N34 . . . .C32 GO SERIES
GOB4-B230CN34CN . .C33 GO SERIES
GOB4-B233C N34 . . . .C32 GO SERIES
GOB4-B233CN34CN . .C33 GO SERIES
GOB4-C230C N34 . . . .C32 GO SERIES
GOB4-C230CN34CN . .C33 GO SERIES
GOB4-C233C N34 . . . .C32 GO SERIES
GOB4-C233CN34CN . .C33 GO SERIES
GOB4-F230C N34 . . . .C32 GO SERIES
GOB4-F230CN34CN . .C33 GO SERIES
GOB4-F233C N34 . . . .C32 GO SERIES
GOB4-F233CN34CN . .C33 GO SERIES
GOB4-G230C N34 . . . .C32 GO SERIES
GOB4-G230C N34 LED .C32 GO SERIES
GOB4-G230CN34CN . .C33 GO SERIES
GOB4-G230CN34LEDCN C33 GO SERIES
GOB4-G233C N34 . . . .C32 GO SERIES
GOB4-G233C N34 LED .C32 GO SERIES
GOB4-G233CN34CN . .C33 GO SERIES
GOB4-G233CN34LEDCN C33 GO SERIES
GOB4-R230C N34 . . . .C32 GO SERIES
GOB4-R230C N34 LED C32 GO SERIES
GOB4-R230CN34CN . .C33 GO SERIES
GOB4-R230CN34LEDCN C33 GO SERIES
GOB4-R233C N34 . . . .C32 GO SERIES
GOB4-R233C N34 LED C32 GO SERIES
GOB4-R233CN34CN . .C33 GO SERIES
GOB4-R233CN34LEDCN C33 GO SERIES
GOL113 . . . . . . . . . . . .C36 GO SERIES
GOL114 . . . . . . . . . . . .C36 GO SERIES
GOL14 . . . . . . . . . . . . .C34 GO SERIES
GOL146 . . . . . . . . . . . .C34 GO SERIES
GOL15 . . . . . . . . . . . . .C34 GO SERIES
GOL156 . . . . . . . . . . . .C34 GO SERIES
GOL1G . . . . . . . . . . . . .C31 GO SERIES
GOL1G1 . . . . . . . . . . . .C31 GO SERIES
GOL1G3 . . . . . . . . . . . .C31 GO SERIES
GOL1K . . . . . . . . . . . . .C31 GO SERIES
GOL1K1 . . . . . . . . . . . .C31 GO SERIES
GOL1K2 . . . . . . . . . . . .C31 GO SERIES
GOL1K3 . . . . . . . . . . . .C31 GO SERIES
GOL1R . . . . . . . . . . . . .C31 GO SERIES
GOL1R2 . . . . . . . . . . . .C31 GO SERIES
GOL1R3 . . . . . . . . . . . .C31 GO SERIES
GOL2GR . . . . . . . . . . . .C31 GO SERIES
GOL2GR12 . . . . . . . . . .C31 GO SERIES
GOL2GR33 . . . . . . . . . .C31 GO SERIES
GOL2KK . . . . . . . . . . . .C31 GO SERIES
GOL2KK12 . . . . . . . . . .C31 GO SERIES
GOL2KK33 . . . . . . . . . .C31 GO SERIES
GOL36L022D . . . . . . . .C35 GO SERIES
GOL36L322D . . . . . . . .C35 GO SERIES
GOL37C032D . . . . . . .C35 GO SERIES
GOL37C632D . . . . . . .C35 GO SERIES
GOL38L032D . . . . . . . .C35 GO SERIES
GOL38L632D . . . . . . . .C35 GO SERIES
GOL39R032D . . . . . . . .C35 GO SERIES
GOL39R632D . . . . . . . .C35 GO SERIES
GOL3A . . . . . . . . . . . . .C32 GO SERIES
GOL3A LED . . . . . . . . .C32 GO SERIES
GOL3ACN . . . . . . . . . .C33 GO SERIES
GOL3ALEDCN . . . . . . .C33 GO SERIES
GOL3B . . . . . . . . . . . . .C32 GO SERIES
GOL3BCN . . . . . . . . . .C33 GO SERIES
GOL3C . . . . . . . . . . . . .C32 GO SERIES
GOL3CCN . . . . . . . . . .C33 GO SERIES
GOL3F . . . . . . . . . . . . .C32 GO SERIES
GOL3FCN . . . . . . . . . . .C33 GO SERIES
GOL3G . . . . . . . . . . . . .C32 GO SERIES
GOL3G LED . . . . . . . . .C32 GO SERIES
GOL3GCN . . . . . . . . . .C33 GO SERIES
GOL3GLEDCN . . . . . . .C33 GO SERIES
GOL3R . . . . . . . . . . . . .C32 GO SERIES
GOL3R LED . . . . . . . . .C32 GO SERIES
GOL3RCN . . . . . . . . . .C33 GO SERIES
GOL3RLEDCN . . . . . . .C33 GO SERIES
GOL4A . . . . . . . . . . . . .C32 GO SERIES
GOL4A LED . . . . . . . . .C32 GO SERIES
GOL4A0CN . . . . . . . . .C33 GO SERIES
GOL4A0LEDCN . . . . . .C33 GO SERIES
GOL4A3 . . . . . . . . . . . .C32 GO SERIES
GOL4A3 LED . . . . . . . .C32 GO SERIES
GOL4A3CN . . . . . . . . .C33 GO SERIES
GOL4A3LEDCN . . . . . .C33 GO SERIES
GOL4B . . . . . . . . . . . . .C32 GO SERIES
GOL4B0CN . . . . . . . . .C33 GO SERIES
GOL4B3 . . . . . . . . . . . .C32 GO SERIES
GOL4B3CN . . . . . . . . .C33 GO SERIES
GOL4C . . . . . . . . . . . . .C32 GO SERIES
GOL4C0CN . . . . . . . . .C33 GO SERIES
GOL4C3 . . . . . . . . . . . .C32 GO SERIES
GOL4C3CN . . . . . . . . .C33 GO SERIES
GOL4F . . . . . . . . . . . . .C32 GO SERIES
GOL4F0CN . . . . . . . . . .C33 GO SERIES
GOL4F3 . . . . . . . . . . . .C32 GO SERIES
GOL4F3CN . . . . . . . . . .C33 GO SERIES
GOL4G . . . . . . . . . . . . .C32 GO SERIES
GOL4G LED . . . . . . . . .C32 GO SERIES
GOL4G0CN . . . . . . . . .C33 GO SERIES
GOL4G0LEDCN . . . . . .C33 GO SERIES
GOL4G3 . . . . . . . . . . . .C32 GO SERIES
GOL4G3 LED . . . . . . . .C32 GO SERIES
GOL4G3CN . . . . . . . . .C33 GO SERIES
GOL4G3LEDCN . . . . . .C33 GO SERIES
GOL4R . . . . . . . . . . . . .C32 GO SERIES
GOL4R LED . . . . . . . . .C32 GO SERIES
GOL4R0CN . . . . . . . . .C33 GO SERIES
GOL4R0LEDCN . . . . . .C33 GO SERIES
GOL4R3 . . . . . . . . . . . .C32 GO SERIES
GOL4R3 LED . . . . . . . .C32 GO SERIES
GOL4R3CN . . . . . . . . .C33 GO SERIES
GOL4R3LEDCN . . . . . .C33 GO SERIES
GOL52A . . . . . . . . . . . .C34 GO SERIES
GOL52A3 . . . . . . . . . . .C34 GO SERIES
GOL53C . . . . . . . . . . . .C34 GO SERIES
GOL53C3 . . . . . . . . . . .C34 GO SERIES
GOL54H . . . . . . . . . . . .C34 GO SERIES
GOL54H8 . . . . . . . . . . .C34 GO SERIES
GOL6 . . . . . . . . . . . . . .C34 GO SERIES
GOL63 . . . . . . . . . . . . .C34 GO SERIES
GOL7 . . . . . . . . . . . . . .C34 GO SERIES
GOL76 . . . . . . . . . . . . .C34 GO SERIES
GOL82A022D . . . . . . . .C35 GO SERIES
GOL82A322D . . . . . . . .C35 GO SERIES
GOL83C032D . . . . . . .C35 GO SERIES
GOL83C332D . . . . . . .C35 GO SERIES
GOLED-A110 . . . . .C27,39 X/XCS SERIES
GOLED-A24 . . . . . .C27,39 X/XCS SERIES
GOLED-B110 . . . . . . . .C39 GO SERIES
GOLED-B24 . . . . . . . . .C39 GO SERIES
GOLED-G110 . . .C27,38,39 X/XCS SERIES
GOLED-G24 . . . . . .C27,39 X/XCS SERIES
GOLED-R110 . . .C27,38,39 X/XCS SERIES
GOLED-R110 . . . . . . . .C38 GO SERIES
GOLED-R24 . . . . . .C27,39 X/XCS SERIES
GOLED-W110 . . . . . . .C39 GO SERIES
GOLED-W24 . . . . . . . .C39 GO SERIES
GOLRST . . . . . . . . . . . .C36 GO SERIES
GOM1-GM0C N34 . . .C31 GO SERIES
GOM1-GM3C N34 . . .C31 GO SERIES
GOM1-KM0C N34 . . . .C31 GO SERIES
GOM1-KM3C N34 . . . .C31 GO SERIES
GOM1-RM0C N34 . . . .C31 GO SERIES
GOM1-RM3C N34 . . . .C31 GO SERIES
GOM21-GM0C . . . . . .C31 GO SERIES
GOM21-GM3C . . . . . .C31 GO SERIES
GOM21-KM0C . . . . . . .C31 GO SERIES
GOM21-KM3C . . . . . . .C31 GO SERIES
GOM21-RM0C . . . . . . .C31 GO SERIES
GOM21-RM3C . . . . . . .C31 GO SERIES
GOMJUR . . . . . . . . . . .C39 GO SERIES
GOML1G . . . . . . . . . . .C31 GO SERIES
GOML1G3 . . . . . . . . . .C31 GO SERIES
GOML1K . . . . . . . . . . .C31 GO SERIES
GOML1K3 . . . . . . . . . .C31 GO SERIES
GOML1R . . . . . . . . . . .C31 GO SERIES
GOML1R3 . . . . . . . . . .C31 GO SERIES
GOMLOCK . . . . . . . . . .C39 GO SERIES
GOMSTG . . . . . . . . . . .C39 GO SERIES
GOMSTK . . . . . . . . . . .C39 GO SERIES
GOMSTR . . . . . . . . . . .C39 GO SERIES
GOR11-GR0D N34 . . . .C31 GO SERIES
GOR11-GR6D N34 . . . .C31 GO SERIES
GOR11-GR7D N34 . . . .C31 GO SERIES
GOR11-GR8D N34 . . . .C31 GO SERIES
GO-RL . . . . . . . . . . . . .C38 GO SERIES
GO-RST . . . . . . . . . . . .C36 GO SERIES
GRB . . . . . . . . . . . . . . . .E24 GR SERIES
GRB-275L . . . . . . . . . . .E24 GR SERIES
GRBB . . . . . . . . . . . . . .E24 GR SERIES
GRB-BC . . . . . . . . . . . .E24 GR SERIES
GRB-RG . . . . . . . . . . . .E24 GR SERIES
GRCEX-0 . . . . . . . . .F57,58 GR SERIES
GRE . . . . . . . . . . . . . . . .E24 GR SERIES
GRE-300L . . . . . . . . . . .E24 GR SERIES
GREB . . . . . . . . . . . . . . .E24 GR SERIES
GRE-BC . . . . . . . . . . . .E24 GR SERIES
GRE-RG . . . . . . . . . . . .E24 GR SERIES
GRH . . . . . . . . . . . . . . .E24 GR SERIES
GRH-775L . . . . . . . . . . .E24 GR SERIES
GRH-775L52B . . . . . . .E26 GR SERIES
GRHA . . . . . . . . . . . . . .E24 GR SERIES
GRHA-775L . . . . . . . . .E24 GR SERIES
GRHAB . . . . . . . . . . . . .E24 GR SERIES
GRHB . . . . . . . . . . . . . .E24 GR SERIES
GRH-BC . . . . . . . . . . . .E24 GR SERIES
GRHC . . . . . . . . . . . . . .E24 GR SERIES
GRHC-775L . . . . . . . . .E24 GR SERIES
GRHCB . . . . . . . . . . . . .E24 GR SERIES
GRH-RG . . . . . . . . . . . .E24 GR SERIES
GRK . . . . . . . . . . . . . . . .E24 GR SERIES
GRK-537L . . . . . . . . . . .E24 GR SERIES
GRK-537L52A . . . . . . .E26 GR SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
N7
GRK-537L52B . . . . . . .E26 GR SERIES
GRKB . . . . . . . . . . . . . .E24 GR SERIES
GRK-BC . . . . . . . . . . . .E24 GR SERIES
GRK-RG . . . . . . . . . . . .E24 GR SERIES
GRL . . . . . . . . . . . . . . . .E24 GR SERIES
GRL-600L . . . . . . . . . . .E24 GR SERIES
GRL-600L52B . . . . . . . .E26 GR SERIES
GRL-600L52C . . . . . . .E26 GR SERIES
GRLB . . . . . . . . . . . . . . .E24 GR SERIES
GRL-BC . . . . . . . . . . . .E24 GR SERIES
GRL-RG . . . . . . . . . . . .E24 GR SERIES
GRM . . . . . . . . . . . . . . .E24 GR SERIES
GRM-375L . . . . . . . . . .E24 GR SERIES
GRM-375L52 . . . . . . . .E26 GR SERIES
GRMB . . . . . . . . . . . . . .E24 GR SERIES
GRM-BC . . . . . . . .F56,E24 GR SERIES
GRM-RG . . . . . . . .F56,E24 GR SERIES
GRR-1 . . . . . . . . . . . . . .F57 GR SERIES
GRR-2 . . . . . . . . . . . . . .F57 GR SERIES
GRR-3 . . . . . . . . . . . . . .F57 GR SERIES
GRSA . . . . . . . . . . . . . .F57 GR SERIES
GRSS-1 . . . . . . . . . . . . .F58 GR SERIES
GRSS-1M . . . . . . . . . . .F58 GR SERIES
GRSS-2 . . . . . . . . . . . . .F58 GR SERIES
GRSS-2M . . . . . . . . . . .F58 GR SERIES
GRSS-3 . . . . . . . . . . . . .F58 GR SERIES
GRSS-3M . . . . . . . . . . .F58 GR SERIES
GRSSA-1 . . . . . . . . . . .F58 GR SERIES
GRSSA-2 . . . . . . . . . . .F58 GR SERIES
GUF-0 . . . . . . . . . . . . . .F61 GU SERIES
GUF-1 . . . . . . . . . . . . . .F61 GU SERIES
GUF-2 . . . . . . . . . . . . . .F61 GU SERIES
GUF-3 . . . . . . . . . . . . . .F61 GU SERIES
GUF-4 . . . . . . . . . . . . . .F61 GU SERIES
GUF-5 . . . . . . . . . . . . . .F61 GU SERIES
GUF-6 . . . . . . . . . . . . . .F61 GU SERIES
GUF-7 . . . . . . . . . . . . . .F61 GU SERIES
GUF-8 . . . . . . . . . . . . . .F61 GU SERIES
GUF-9 . . . . . . . . . . . . . .F61 GU SERIES
GUFS-1 . . . . . . . . . . . . .F66 GU SERIES
GUFS-1M . . . . . . . . . . .F66 GUFS SERIES
GUFS-2 . . . . . . . . . . . . .F66 GU SERIES
GUFS-2M . . . . . . . . . . .F66 GUFS SERIES
GUM-0 . . . . . . . . . . . . .F61 GU SERIES
GUM-1 . . . . . . . . . . . . .F61 GU SERIES
GUM-2 . . . . . . . . . . . . .F61 GU SERIES
GUM-3 . . . . . . . . . . . . .F61 GU SERIES
GUM-4 . . . . . . . . . . . . .F61 GU SERIES
GUM-5 . . . . . . . . . . . . .F61 GU SERIES
GUM-6 . . . . . . . . . . . . .F61 GU SERIES
GUM-7 . . . . . . . . . . . . .F61 GU SERIES
GUM-8 . . . . . . . . . . . . .F61 GU SERIES
GUM-9 . . . . . . . . . . . . .F61 GU SERIES
GUMFS-1 . . . . . . . . . . .F66 GU SERIES
GUMFS-1M . . . . . . . . .F66 GUMF SERIES
GUMFS-2 . . . . . . . . . . .F66 GU SERIES
GUMFS-2M . . . . . . . . .F66 GUMF SERIES
GUML-1 . . . . . . . . . . . .F61 GU SERIES
GUML-1M . . . . . . . . . .F61 GU SERIES
GUML-2 . . . . . . . . . . . .F61 GU SERIES
GUML-2M . . . . . . . . . .F61 GU SERIES
HSERIESACC...............................L16
HEXA-100 . . . . . .L141,211 EM/EB/EQ SERIES
HFC . . . . . . . . . . . . . . . .E29 HK/2HK SERIES
HFXSERIES ............................L178-183
HFXESERIES...............................L210
HFX-SC . . . . . . . . . . .L183 HFX SERIES
HG-200 . . . . . . . . . . . . .L16 E SERIES
HIC-SILVER . . . . . . . .L221 HIC SERIES
HINGE-10L . . . . . . .E16,18 ENCLOSURE ACC
HINGE-10R . . . . . . . . . .E18 ENCLOSURE ACC
HINGE-11L . . . . . .E3,16,18 ENCLOSURE ACC
HINGE-11R . . . . . . . . . .E18 ENCLOSURE ACC
HINGE-4 . . . . . . . . . . . . .E3 ENCLOSURE ACC
HINGE-9 . . . . . . . . .E16,18 ENCLOSURE ACC
HINGE-9R . . . . . . . . . . .E18 ENCLOSURE ACC
HK1GLD . . . . . . . . . . . .E29 HK/2HK SERIES
HK2D . . . . . . . . . . . . . .E29 HK/2HK SERIES
HK2GLD . . . . . . . . . . . .E29 HK/2HK SERIES
HK4D . . . . . . . . . . . . . .E29 HK/2HK SERIES
HKB . . . . . . . . . . . . . . . .E29 HK/2HK SERIES
HKB-2D . . . . . . . . . . . .E29 HK/2HK SERIES
HKB-2DC . . . . . . . . . . .E29 HK/2HK SERIES
HKB-2GLD . . . . . . . . . .E29 HK/2HK SERIES
HKB-2GLDC . . . . . . . . .E29 HK/2HK SERIES
HKB-4D . . . . . . . . . . . .E29 HK/2HK SERIES
HKB-4DC . . . . . . . . . . .E29 HK/2HK SERIES
HKB-B . . . . . . . . . . . . . .E29 HK/2HK SERIES
HKB-BC . . . . . . . . . . . .E29 HK/2HK SERIES
HKBD . . . . . . . . . . . . . .E29 HK/2HK SERIES
HKBD-2D . . . . . . . . . . .E29 HK/2HK SERIES
HKBD-2GLD . . . . . . . . .E29 HK/2HK SERIES
HKBD-4D . . . . . . . . . . .E29 HK/2HK SERIES
HKBD-B . . . . . . . . . . . .E29 HK/2HK SERIES
HKBD-GL . . . . . . . . . . .E29 HK/2HK SERIES
HKB-GL . . . . . . . . . . . .E29 HK/2HK SERIES
HKB-GLC . . . . . . . . . . .E29 HK/2HK SERIES
HKGL . . . . . . . . . . . . . .E29 HK/2HK SERIES
HKSB-BC . . . . . . . . . . .E29 HK/2HK SERIES
HKSB-GLC . . . . . . . . . .E29 HK/2HK SERIES
HOOKLOOP ................................L219
HRD400 . . . . . . . . . . . .L95 VM SERIES
HRD400ALZ . . . . . . . . .L95 VM SERIES
HRME . . . . . . . . . . . . . .L16 E SERIES
HXB-11 . . . . . . . . . . . .L221 HXB SERIES
HXB-12 . . . . . . . . . . . .L221 HXB SERIES
HXB-21 . . . . . . . . . . . .L221 HXB SERIES
HXB-22 . . . . . . . . . . . .L221 HXB SERIES
HXBC . . . . . . . . . . . . .L221 HXB SERIES
JABC . . . . . . . . . . . . . . .F60 JL/JAL SERIES
JAH-1 . . . . . . . . . . . . . .F60 JL/JAL SERIES
JAH-2 . . . . . . . . . . . . . .F60 JL/JAL SERIES
JALX-10 . . . . . . . . . . . .F60 JAL SERIES
JALX-11 . . . . . . .F60,L222 JAL SERIES
JALX-12 . . . . . . .F60,L222 JAL SERIES
JALX-20 . . . . . . . . . . . .F60 JAL SERIES
JALX-21 . . . . . . .F60,L222 JAL SERIES
JALX-22 . . . . . . .F60,L222 JAL SERIES
JALX-3 . . . . . . . . . . . .PR21 JAL SERIES
JALX-30 . . . . . . . . . . . .F60 JAL SERIES
JALX-31 . . . . . . .F60,L222 JAL SERIES
JALX-32 . . . . . . .F60,L222 JAL SERIES
JALX-4 . . . . . . . . . . . .PR21 JAL SERIES
JALX-40 . . . . . . . . . . . .F60 JAL SERIES
JCB . . . . . . . . . . . . . . . .F60 JL/JAL SERIES
JH-1 . . . . . . . . . . . . . . .F60 JL/JAL SERIES
JH-2 . . . . . . . . . . . . . . .F60 JL/JAL SERIES
JLC-1 . . . . . . . . . . . . .PR19 KR SERIES
JLC-10 . . . . . . . . . . . . .F60 JL SERIES
JLC-11 . . . . . . . .F60,L222 JL SERIES
JLC-12 . . . . . . . .F60,L222 JL SERIES
JLC-2 . . . . . . . . . . . . .PR19 KR SERIES
JLC-20 . . . . . . . . . . . . .F60 JL SERIES
JLC-21 . . . . . . . .F60,L222 JL SERIES
JLC-22 . . . . . . . .F60,L222 JL SERIES
JLX-1 . . . . . . . . . . . . .PR19 KR SERIES
JLX-10 . . . . . . . . . . . . .F60 JL SERIES
JLX-11 . . . . . . . . .F60,L222 JL SERIES
JLX-12 . . . . . . . . .F60,L222 JL SERIES
JLX-2 . . . . . . . . . . . . .PR19 KR SERIES
JLX-20 . . . . . . . . . . . . .F60 JL SERIES
JLX-21 . . . . . . . . . . . . .F60 JL SERIES
JLX-22 . . . . . . . . .F60,L222 JL SERIES
K038 . . . . . . . . . . . . . . .F70 K SERIES
K0381 . . . . . . . . . . . . . .F70 K SERIES
K0381-G . . . . . . . . . . . .F72 K SERIES
K0384 . . . . . . . . . . . . . .F71 K SERIES
K03841 . . . . . . . . . . . . .F71 K SERIES
K03841-G . . . . . . . . . . .F72 K SERIES
K0389 . . . . . . . . . . . . . .F71 K SERIES
K03891 . . . . . . . . . . . . .F71 K SERIES
K03891-G . . . . . . . . . . .F72 K SERIES
K050 . . . . . . . . . . . . . . .F70 K SERIES
K0501 . . . . . . . . . . . . . .F70 K SERIES
K0501-G . . . . . . . . . . . .F72 K SERIES
K0504 . . . . . . . . . . . . . .F71 K SERIES
K05041 . . . . . . . . . . . . .F71 K SERIES
K05041-G . . . . . . . . . . .F72 K SERIES
K0509 . . . . . . . . . . . . . .F71 K SERIES
K05091 . . . . . . . . . . . . .F71 K SERIES
K05091-G . . . . . . . . . . .F72 K SERIES
K075 . . . . . . . . . . . . . . .F70 K SERIES
K0751 . . . . . . . . . . . . . .F70 K SERIES
K0751-G . . . . . . . . . . . .F72 K SERIES
K0754 . . . . . . . . . . . . . .F71 K SERIES
K07541 . . . . . . . . . . . . .F71 K SERIES
K07541-G . . . . . . . . . . .F72 K SERIES
K0759 . . . . . . . . . . . . . .F71 K SERIES
K07591 . . . . . . . . . . . . .F71 K SERIES
K07591-G . . . . . . . . . . .F72 K SERIES
K100 . . . . . . . . . . . . . . .F70 K SERIES
K1001 . . . . . . . . . . . . . .F70 K SERIES
K1001-G . . . . . . . . . . . .F72 K SERIES
K1004 . . . . . . . . . . . . . .F71 K SERIES
K10041 . . . . . . . . . . . . .F71 K SERIES
K10041-G . . . . . . . . . . .F72 K SERIES
K1009 . . . . . . . . . . . . . .F71 K SERIES
K10091 . . . . . . . . . . . . .F71 K SERIES
K10091-G . . . . . . . . . . .F72 K SERIES
K125 . . . . . . . . . . . . . . .F70 K SERIES
K1251 . . . . . . . . . . . . . .F70 K SERIES
K1251-G . . . . . . . . . . . .F72 K SERIES
K1254 . . . . . . . . . . . . . .F71 K SERIES
K12541 . . . . . . . . . . . . .F71 K SERIES
K12541-G . . . . . . . . . . .F72 K SERIES
K1259 . . . . . . . . . . . . . .F71 K SERIES
K12591 . . . . . . . . . . . . .F71 K SERIES
K12591-G . . . . . . . . . . .F72 K SERIES
K150 . . . . . . . . . . . . . . .F70 K SERIES
K1501 . . . . . . . . . . . . . .F70 K SERIES
K1501-G . . . . . . . . . . . .F72 K SERIES
K1504 . . . . . . . . . . . . . .F71 K SERIES
K15041 . . . . . . . . . . . . .F71 K SERIES
K15041-G . . . . . . . . . . .F72 K SERIES
K1509 . . . . . . . . . . . . . .F71 K SERIES
K15091 . . . . . . . . . . . . .F71 K SERIES
K15091-G . . . . . . . . . . .F72 K SERIES
K200 . . . . . . . . . . . . . . .F70 K SERIES
K2001 . . . . . . . . . . . . . .F70 K SERIES
K2001-G . . . . . . . . . . . .F72 K SERIES
K2004 . . . . . . . . . . . . . .F71 K SERIES
K20041 . . . . . . . . . . . . .F71 K SERIES
K20041-G . . . . . . . . . . .F72 K SERIES
K2009 . . . . . . . . . . . . . .F71 K SERIES
K20091 . . . . . . . . . . . . .F71 K SERIES
K20091-G . . . . . . . . . . .F72 K SERIES
K250 . . . . . . . . . . . . . . .F70 K SERIES
K2501 . . . . . . . . . . . . . .F70 K SERIES
K2501-G . . . . . . . . . . . .F72 K SERIES
K25091 . . . . . . . . . . . . .F71 K SERIES
K25091-G . . . . . . . . . . .F72 K SERIES
K300 . . . . . . . . . . . . . . .F70 K SERIES
K3001 . . . . . . . . . . . . . .F70 K SERIES
K3001-G . . . . . . . . . . . .F72 K SERIES
K3009 . . . . . . . . . . . . . .F71 K SERIES
K30091 . . . . . . . . . . . . .F71 K SERIES
K30091-G . . . . . . . . . . .F72 K SERIES
K350 . . . . . . . . . . . . . . .F70 K SERIES
K3501 . . . . . . . . . . . . . .F70 K SERIES
K3501-G . . . . . . . . . . . .F72 K SERIES
K400 . . . . . . . . . . . . . . .F70 K SERIES
K4001 . . . . . . . . . . . . . .F70 K SERIES
K4001-G . . . . . . . . . . . .F72 K SERIES
K4009 . . . . . . . . . . . . . .F71 K SERIES
K40091 . . . . . . . . . . . . .F71 K SERIES
K40091-G . . . . . . . . . . .F72 K SERIES
K4040 . . . . . . . . . . . . .L190 KF SERIES
K4040G . . . . . . . . . . . .L192 KFSS SERIES
KB1B . . . . . . . . . . .F64,E20 ENCLOSURE ACC
KB1BCEN . . . . . . .F64,E20 ENCLOSURE ACC
KB1D . . . . . . . . . . .F64,E20 ENCLOSURE ACC
KB1DCEN . . . . . . .F64,E20 ENCLOSURE ACC
KB1FA25 . . . . . . . .F64,E20 ENCLOSURE ACC
KB1FAM16 . . . . . .F64,E20 ENCLOSURE ACC
KBM20BCEN . . . . .F64,E20 ENCLOSURE ACC
KBM20DCEN . . . .F64,E20 ENCLOSURE ACC
KBM20FA25 . . . . .F64,E20 ENCLOSURE ACC
KBM20FAM16 . . . .F64,E20 ENCLOSURE ACC
KDB-1 . . . . . . . . . .F64,E20 ENCLOSURE ACC
KDB-250 . . . . . . . .F64,E20 ENCLOSURE ACC
KDB-250CEN . . . .F64,E20 ENCLOSURE ACC
KDB-375 . . . . . . . .F64,E20 ENCLOSURE ACC
KDB-375 . . . . . . . .F64,E20 ENCLOSURE ACC
KDB-M16CEN . . . .F64,E20 ENCLOSURE ACC
KEFHM-75 . . . . . . . . .L183 KEFHM SERIES
KESD-75 . . . . . . . . . . .L183 KESD SERIES
KFSERIES .............................L189-190
KFCB . . . . . . . . . . . . . .L190 KF SERIES
KFCBG . . . . . . . . . . . .L192 KFSS SERIES
KF-DOOR . . . . . . . . . .L190 KF SERIES
KFHS5075 . . . . . . . . .L183 KFHS SERIES
KFS-6 . . . . . . . . . . . . .L190 KF SERIES
KFS-6G . . . . . . . . . . . .L192 KFSS SERIES
KFSSSERIES...............................L192
KFWB . . . . . . . . . . . . .L190 KF SERIES
KILLN1 . . . . .F74,75,78,79 Z SERIES
KILLN2 . . . . .F74,75,78,79 Z SERIES
KILLN3 . . . . .F74,75,78,79 Z SERIES
KILLN375 . . .F74,75,78,79 Z SERIES
KILLN4 . . . . .F74,75,78,79 Z SERIES
KILLN5 . . . . .F74,75,78,79 Z SERIES
KILLN6 . . . . .F74,75,78,79 Z SERIES
KILLN7 . . . . .F74,75,78,79 Z SERIES
KILLN8 . . . . .F74,75,78,79 Z SERIES
KIT-232 . . . . . . . . . . . . .C29 XAL/XAS SERIES
KIT-251 . . . . . . . . . . . . . .E2 ENCLOSURE ACC
KIT-252 . . . . . . . . . . . . . .E2 EXB SERIES
KIT-354 . . . . . . . . . . . . .C38 GO SERIES
KIT-355 . . . . . . . . . . . . .C38 GO SERIES
KIT-356 . . . . . . . . . . . . .C38 GO SERIES
KIT-357 . . . . . . . . . . . . .C38 GO SERIES
KIT-358 . . . . . . . . . . . . .C38 GO SERIES
KIT-359 . . . . . . . . . . . . .C38 GO SERIES
KOR-1 . . . . . .F74,75,78,79 Z SERIES
KOR-2 . . . . . .F74,75,78,79 Z SERIES
KOR-3 . . . . . .F74,75,78,79 Z SERIES
KOR-4 . . . . . .F74,75,78,79 Z SERIES
KOR-5 . . . . . .F74,75,78,79 Z SERIES
KOR-6 . . . . . .F74,75,78,79 Z SERIES
KP-20ABC . . . . . . . . .PR19 KR SERIES
KP-303D23 . . . . . . . .PR20 KR SERIES
KP-303D45 . . . . . . . .PR20 KR SERIES
KP-303E45 . . . . . . . . .PR20 KR SERIES
KP-303E67 . . . . . . . . .PR20 KR SERIES
KP-304D23 . . . . . . . .PR20 KR SERIES
KP-304D45 . . . . . . . .PR20 KR SERIES
KP-304E45 . . . . . . . . .PR20 KR SERIES
KP-304E67 . . . . . . . . .PR20 KR SERIES
KP-603D345 . . . . . . .PR21 KR SERIES
KP-603E45 . . . . . . . . .PR21 KR SERIES
KP-603E67 . . . . . . . . .PR21 KR SERIES
KP-604D345 . . . . . . .PR21 KR SERIES
KP-604E45 . . . . . . . . .PR21 KR SERIES
KP-604E67 . . . . . . . . .PR21 KR SERIES
KP-604F34 . . . . . . . . .PR21 KR SERIES
KP-604F56 . . . . . . . . .PR21 KR SERIES
KRAJAC-4603 . . . . . .PR21 KR SERIES
KRAJAC-4604 . . . . . .PR21 KR SERIES
KRAJAC-5603 . . . . . .PR21 KR SERIES
KRAJAC-5604 . . . . . .PR21 KR SERIES
KRAJAC-6603 . . . . . .PR21 KR SERIES
KRAJAC-6604 . . . . . .PR21 KR SERIES
KRAJAT-4603 . . . . . . .PR21 KR SERIES
KRAJAT-4604 . . . . . . .PR21 KR SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
INTRODUCTION
NUMERIC INDEX
INTRODUCTION
NUMERIC INDEX
N8
KRAJAT-5603 . . . . . . .PR21 KR SERIES
KRAJAT-5604 . . . . . . .PR21 KR SERIES
KRAJC-220 . . . . . . . .PR19 KR SERIES
KRAJC-2303 . . . . . . .PR20 KR SERIES
KRAJC-2304 . . . . . . .PR20 KR SERIES
KRAJC-320 . . . . . . . .PR19 KR SERIES
KRAJC-3303 . . . . . . .PR20 KR SERIES
KRAJC-3304 . . . . . . .PR20 KR SERIES
KRJ-20 . . . . . . . . . . . .PR19 KR SERIES
KRJ-303 . . . . . . . . . . .PR20 KR SERIES
KRJ-304 . . . . . . . . . . .PR20 KR SERIES
KRJ-603 . . . . . . . . . . .PR21 KR SERIES
KRJ-604 . . . . . . . . . . .PR21 KR SERIES
KRJC-120 . . . . . . . . .PR19 KR SERIES
KRJC-1303 . . . . . . . .PR20 KR SERIES
KRJC-1304 . . . . . . . .PR20 KR SERIES
KRJC-220 . . . . . . . . .PR19 KR SERIES
KRJC-2303 . . . . . . . .PR20 KR SERIES
KRJC-2304 . . . . . . . .PR20 KR SERIES
KRJX-120 . . . . . . . . . .PR19 KR SERIES
KRJX-1303 . . . . . . . . .PR20 KR SERIES
KRJX-1304 . . . . . . . . .PR20 KR SERIES
KRJX-220 . . . . . . . . . .PR19 KR SERIES
KRJX-2303 . . . . . . . . .PR20 KR SERIES
KRJX-2304 . . . . . . . . .PR20 KR SERIES
KRJX-3603 . . . . . . . . .PR21 KR SERIES
KRJX-3604 . . . . . . . . .PR21 KR SERIES
KRJX-4603 . . . . . . . . .PR21 KR SERIES
KRJX-4604 . . . . . . . . .PR21 KR SERIES
KRS-20 . . . . . . . . . . . .PR19 KR SERIES
KRS-215-120 . . . . . . .PR19 KR SERIES
KRS-215-1303 . . . . . .PR20 KR SERIES
KRS-215-1304 . . . . . .PR20 KR SERIES
KRS-215-220 . . . . . . .PR19 KR SERIES
KRS-215-2303 . . . . . .PR20 KR SERIES
KRS-215-2304 . . . . . .PR20 KR SERIES
KRS-215-320 . . . . . . .PR19 KR SERIES
KRS-215-3303 . . . . . .PR20 KR SERIES
KRS-215-3304 . . . . . .PR20 KR SERIES
KRS-218-120 . . . . . . .PR19 KR SERIES
KRS-218-1303 . . . . . .PR20 KR SERIES
KRS-218-1304 . . . . . .PR20 KR SERIES
KRS-218-220 . . . . . . .PR19 KR SERIES
KRS-218-2303 . . . . . .PR20 KR SERIES
KRS-218-2304 . . . . . .PR20 KR SERIES
KRS-218-320 . . . . . . .PR19 KR SERIES
KRS-218-3303 . . . . . .PR20 KR SERIES
KRS-218-3304 . . . . . .PR20 KR SERIES
KRS-303 . . . . . . . . . . .PR20 KR SERIES
KRS-304 . . . . . . . . . . .PR20 KR SERIES
KT-100SU41G . . . . . .L141 EM/EB/EQ SERIES
KT-100SU41R . . . . . .L141 EM/EB/EQ SERIES
KWPSERIES ...........................L194-195
KWPLENS . . . . . . . . . .L195 KWP SERIES
L17 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L17SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L27 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L27SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L37 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L37SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L47 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L47SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L57 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L57SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L67 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L67SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L77 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L77SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L87 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
L87SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
LB107 . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB107SA . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB108 . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LB17 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB17SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB18 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LB27 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB27SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB28 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LB37 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB37SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB38 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LB448 . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LB47 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB47SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB57 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB57SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB58 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LB67 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB67SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB68 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LB77 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB77SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB78 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LB87 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB87SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB888 . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LB97 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB97SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LB98 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LL107 . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL107SA . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL17 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL17SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL18 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LL27 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL27SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL28 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LL37 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL37SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL38 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LL448 . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LL47 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL47SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL57 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL57SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL58 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LL67 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL67SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL68 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LL77 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL77SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL78 . . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LL87 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL87SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL888 . . . . . . . . . . . . . .F11 DURALOY 8 SERIES
LL97 . . . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LL97SA . . . . . . . . . . . . . .F7 DURALOY 7 SERIES
LN1CR . . . . . . . .F76,80,81 Z SERIES
LN2CR . . . . . . . .F76,80,81 Z SERIES
LN375CR . . . . . .F76,80,81 Z SERIES
LN3CR . . . . . . . .F76,80,81 Z SERIES
LNZ10-050NPT . . . . . .F85 LNZ SERIES
LNZ10-075NPT . . . . . .F85 LNZ SERIES
LNZ10-100NPT . . . . . .F85 LNZ SERIES
LNZ10-125NPT . . . . . .F85 LNZ SERIES
LNZ10-150NPT . . . . . .F85 LNZ SERIES
LNZ10-200NPT . . . . . .F85 LNZ SERIES
LNZ10-250NPT . . . . . .F85 LNZ SERIES
LNZ10-300NPT . . . . . .F85 LNZ SERIES
LR107 . . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR107SA . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR17 . . . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR17SA . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR18 . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
LR27 . . . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR27SA . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR28 . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
LR37 . . . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR37SA . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR38 . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
LR448 . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
LR47 . . . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR47SA . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR57 . . . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR57SA . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR58 . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
LR67 . . . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR67SA . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR68 . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
LR77 . . . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR77SA . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR78 . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
LR87 . . . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR87SA . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR888 . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
LR97 . . . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LR97SA . . . . . . . . . . . . . .F3 DURALOY 7 SERIES
LUBG-6 . . . . . . . . . . . . .F48 ENY/EYS/EY/EYD SERIES
LUBT-2 . . . . . . . . . . . . .F48 ENY/EYS/EY/EYD SERIES
LZ2NSERIES ...........................L174-176
LZ2N2BAR . . . . . . . . .L160 LZ2N SERIES
LZ2N2LENS . . . . . . . .L160 LZ2N SERIES
LZ2N4BAR . . . . . . . . .L160 LZ2N SERIES
LZ2N4LENS . . . . . . . .L160 LZ2N SERIES
LZ2NESERIES..............................L209
LZ2SSERIES ...............................L173
LZ2SESERIES ..............................L209
LZ2S-LATCH . . . . . . .L160 LZ2S SERIES
LZAB . . . . . . . . . . . . . .L160 LZ2N/LZ2S SERIES
LZCB . . . . . . . . . . . . . .L160 LZ2N/LZ2S SERIES
LZEB . . . . . . . . . . . . . .L160 LZ2N/LZ2S SERIES
LZWB . . . . . . . . . . . . .L160 LZ2N/LZ2S SERIES
MBSERIES ..............................L22-28
MBA-2 . . . . . . . . . . .L19,26 MB SERIES
MBA-3 . . . . . . . . . . .L19,26 MB SERIES
MBAG . . . . . . . . . . .L19,27 MB SERIES
MBB-2 . . . . . . . . . . .L19,26 MB SERIES
MBB-3 . . . . . . . . . . .L19,26 MB SERIES
MBD-4 . . . . . . . . . . .L19,26 MB SERIES
MBD-5 . . . . . . . . . . .L19,26 MB SERIES
MBF131 . . . . . . . . . . . .L24 MB SERIES
MBF131 . . . . . . . . . . . .L26 MB SERIES
MBF261 . . . . . . . . . . . .L24 MB SERIES
MBF261 . . . . . . . . . . . .L26 MB SERIES
MBF391 . . . . . . . . . . . .L24 MB SERIES
MBF391 . . . . . . . . . . . .L26 MB SERIES
MBG . . . . . . . . . . . .L19,27 MB SERIES
MBH100 . . . . . . . . . . . .L24 MB SERIES
MBH100 . . . . . . . . . . . .L26 MB SERIES
MBH500 . . . . . . . . . . . .L24 MB SERIES
MBH500 . . . . . . . . . . . .L26 MB SERIES
MBH700 . . . . . . . . . . . .L24 MB SERIES
MBH700 . . . . . . . . . . . .L26 MB SERIES
MBLSERIES .............................L17-21
MBL101 . . . . . . . . . . . .L24 MB SERIES
MBL101 . . . . . . . . . . . .L26 MB SERIES
MBL151 . . . . . . . . . . . .L24 MB SERIES
MBL151 . . . . . . . . . . . .L26 MB SERIES
MBL2230 . . . . . . . . . . .L19 MB SERIES
MBL4530 . . . . . . . . . . .L19 MB SERIES
MBL501 . . . . . . . . . . . .L24 MB SERIES
MBL501 . . . . . . . . . . . .L26 MB SERIES
MBL701 . . . . . . . . . . . .L24 MB SERIES
MBL701 . . . . . . . . . . . .L26 MB SERIES
MBX-2 . . . . . . . . . . .L19,26 MB SERIES
MBX-3 . . . . . . . . . . .L19,26 MB SERIES
MBX-8 . . . . . . . . . . .L19,26 MB SERIES
MF-45-1 . . . . . . . . . . . .F66 MF SERIES
MF-45-1M . . . . . . . . . .F66 MF SERIES
MF-45-2 . . . . . . . . . . . .F66 MF SERIES
MF-45-2M . . . . . . . . . .F66 MF SERIES
MF-90-1 . . . . . . . . . . . .F66 MF SERIES
MF-90-1M . . . . . . . . . .F66 MF SERIES
MF-90-2 . . . . . . . . . . . .F66 MF SERIES
MF-90-2M . . . . . . . . . .F66 MF SERIES
MLB-12 . . . . . . . . . .F25,27 MLB SERIES
MM-90-1 . . . . . . . . . . .F66 MM SERIES
MM-90-1M . . . . . . . . .F66 MM SERIES
MM-90-2 . . . . . . . . . . .F66 MM SERIES
MM-90-2M . . . . . . . . .F66 MM SERIES
MOC-0 . . . . . . . . . . . . .F23 MO SERIES
MOC-0M . . . . . . . . . . .F23 MO SERIES
MOC-3 . . . . . . . . . . . . .F23 MO SERIES
MOC-3M . . . . . . . . . . .F23 MO SERIES
MOC-4 . . . . . . . . . . . . .F23 MO SERIES
MOC-4M . . . . . . . . . . .F23 MO SERIES
MOC-5 . . . . . . . . . . . . .F23 MO SERIES
MOC-5M . . . . . . . . . . .F23 MO SERIES
MOC-6 . . . . . . . . . . . . .F23 MO SERIES
MOC-6M . . . . . . . . . . .F23 MO SERIES
MOC-7 . . . . . . . . . . . . .F23 MO SERIES
MOC-7M . . . . . . . . . . .F23 MO SERIES
MOC-8 . . . . . . . . . . . . .F23 MO SERIES
MOC-8M . . . . . . . . . . .F23 MO SERIES
MOC-9 . . . . . . . . . . . . .F23 MO SERIES
MOC-9M . . . . . . . . . . .F23 MO SERIES
MOL-450 . . . . . . . . . . .F25 MOL SERIES
MOL-560 . . . . . . . . . . .F25 MOL SERIES
MOL-6CG . . . . . . . . . . .F25 MOL SERIES
MOL-780 . . . . . . . . . . .F25 MOL SERIES
MOL-900 . . . . . . . . . . .F25 MOL SERIES
MOLB-0 . . . . . . . . . . . .F25 MOL SERIES
MOLB-4 . . . . . . . . . . . .F25 MOL SERIES
MOLB-5 . . . . . . . . . . . .F25 MOL SERIES
MOLB-6 . . . . . . . . . . . .F25 MOL SERIES
MOLB-6CG . . . . . . . . . .F25 MOL SERIES
MOLB-7 . . . . . . . . . . . .F25 MOL SERIES
MOLB-8 . . . . . . . . . . . .F25 MOL SERIES
MOLB-9 . . . . . . . . . . . .F25 MOL SERIES
MOLBD-0 . . . . . . . . . . .F23 MO SERIES
MOLBD-0M . . . . . . . . .F23 MO SERIES
MOLBD-1 . . . . . . . . . . .F23 MO SERIES
MOLBD-1M . . . . . . . . .F23 MO SERIES
MOLBD-2 . . . . . . . . . . .F23 MO SERIES
MOLBD-2M . . . . . . . . .F23 MO SERIES
MOLBD-3 . . . . . . . . . . .F23 MO SERIES
MOLBD-3M . . . . . . . . .F23 MO SERIES
MOLBD-4 . . . . . . . . . . .F23 MO SERIES
MOLBD-4M . . . . . . . . .F23 MO SERIES
MOLBD-5 . . . . . . . . . . .F23 MO SERIES
MOLBD-5M . . . . . . . . .F23 MO SERIES
MOLBD-6 . . . . . . . . . . .F23 MO SERIES
MOLBD-6M . . . . . . . . .F23 MO SERIES
MOLBD-7 . . . . . . . . . . .F23 MO SERIES
MOLBD-7M . . . . . . . . .F23 MO SERIES
MOLBD-8 . . . . . . . . . . .F23 MO SERIES
MOLBD-8M . . . . . . . . .F23 MO SERIES
MOLBD-9 . . . . . . . . . . .F23 MO SERIES
MOLBD-9M . . . . . . . . .F23 MO SERIES
MOT-0 . . . . . . . . . . . . . .F24 MO SERIES
MOT-0M . . . . . . . . . . . .F24 MO SERIES
MOT-3 . . . . . . . . . . . . . .F24 MO SERIES
MOT-3M . . . . . . . . . . . .F24 MO SERIES
MOT-4 . . . . . . . . . . . . . .F24 MO SERIES
MOT-4M . . . . . . . . . . . .F24 MO SERIES
MOT-5 . . . . . . . . . . . . . .F24 MO SERIES
MOT-5M . . . . . . . . . . . .F24 MO SERIES
MOT-6 . . . . . . . . . . . . . .F24 MO SERIES
MOT-6M . . . . . . . . . . . .F24 MO SERIES
MOT-7 . . . . . . . . . . . . . .F24 MO SERIES
MOT-7M . . . . . . . . . . . .F24 MO SERIES
MOT-8 . . . . . . . . . . . . . .F24 MO SERIES
MOT-8M . . . . . . . . . . . .F24 MO SERIES
MOT-9 . . . . . . . . . . . . . .F24 MO SERIES
MOT-9M . . . . . . . . . . . .F24 MO SERIES
MOUB-0 . . . . . . . . . . . .F24 MO SERIES
MOUB-0M . . . . . . . . . .F24 MO SERIES
MOUB-3 . . . . . . . . . . . .F24 MO SERIES
MOUB-3M . . . . . . . . . .F24 MO SERIES
MOUB-4 . . . . . . . . . . . .F24 MO SERIES
MOUB-4M . . . . . . . . . .F24 MO SERIES
MOUB-5 . . . . . . . . . . . .F24 MO SERIES
MOUB-5M . . . . . . . . . .F24 MO SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
N9
MOUB-6 . . . . . . . . . . . .F24 MO SERIES
MOUB-6M . . . . . . . . . .F24 MO SERIES
MOUB-7 . . . . . . . . . . . .F24 MO SERIES
MOUB-7M . . . . . . . . . .F24 MO SERIES
MOUB-8 . . . . . . . . . . . .F24 MO SERIES
MOUB-8M . . . . . . . . . .F24 MO SERIES
MOUB-9 . . . . . . . . . . . .F24 MO SERIES
MOUB-9M . . . . . . . . . .F24 MO SERIES
MPL13 .....................................L26
MQL13 ...................................L3,48
MQL18 ...................................L3,48
MQL26 ...................................L3,48
MQL32 ...................................L3,48
MQL42 ...................................L3,48
NECLB-3 . . . . . . . . . . . .F26 NECLB SERIES
NECLB-30 . . . . . . . . . . .F26 NECLB SERIES
NECLB-4 . . . . . . . . . . . .F26 NECLB SERIES
NECLB-40 . . . . . . . . . . .F26 NECLB SERIES
NECLB-5 . . . . . . . . . . . .F26 NECLB SERIES
NECLB-50 . . . . . . . . . . .F26 NECLB SERIES
NECLB-6 . . . . . . . . . . . .F26 NECLB SERIES
NECLB-60 . . . . . . . . . . .F26 NECLB SERIES
NV2AG . . . . . . . . . . . . . .L3 NV2 SERIES
NV2BG . . . . . . . . . . . . . .L3 NV2 SERIES
NV2CC . . . . . . . . . . . . . .L3 NV2 SERIES
NV2CG . . . . . . . . . . . . . .L3 NV2 SERIES
NV2FG13 . . . . . . . . . . . .L3 NV2 SERIES
NV2FG13AHG . . . . . . . . .L2 NV2 SERIES
NV2FG13ASG . . . . . . . . .L2 NV2 SERIES
NV2FG13BHG . . . . . . . . .L2 NV2 SERIES
NV2FG13BSG . . . . . . . . .L2 NV2 SERIES
NV2FG13XHG . . . . . . . . .L2 NV2 SERIES
NV2FG13XSG . . . . . . . . .L2 NV2 SERIES
NV2FG18 . . . . . . . . . . . .L3 NV2 SERIES
NV2FG18AHG . . . . . . . . .L2 NV2 SERIES
NV2FG18ASG . . . . . . . . .L2 NV2 SERIES
NV2FG18BHG . . . . . . . . .L2 NV2 SERIES
NV2FG18BSG . . . . . . . . .L2 NV2 SERIES
NV2FG18XHG . . . . . . . . .L2 NV2 SERIES
NV2FG18XSG . . . . . . . . .L2 NV2 SERIES
NV2FG26 . . . . . . . . . . . .L3 NV2 SERIES
NV2FG26AHG . . . . . . . . .L2 NV2 SERIES
NV2FG26ASG . . . . . . . . .L2 NV2 SERIES
NV2FG26BHG . . . . . . . . .L2 NV2 SERIES
NV2FG26BSG . . . . . . . . .L2 NV2 SERIES
NV2FG26XHG . . . . . . . . .L2 NV2 SERIES
NV2FG26XSG . . . . . . . . .L2 NV2 SERIES
NV2FG32 . . . . . . . . . . . .L3 NV2 SERIES
NV2FG32AHG . . . . . . . . .L2 NV2 SERIES
NV2FG32ASG . . . . . . . . .L2 NV2 SERIES
NV2FG32BHG . . . . . . . . .L2 NV2 SERIES
NV2FG32BSG . . . . . . . . .L2 NV2 SERIES
NV2FG32XHG . . . . . . . . .L2 NV2 SERIES
NV2FG32XSG . . . . . . . . .L2 NV2 SERIES
NV2FG42 . . . . . . . . . . . .L3 NV2 SERIES
NV2FG42AHG . . . . . . . . .L2 NV2 SERIES
NV2FG42ASG . . . . . . . . .L2 NV2 SERIES
NV2FG42BHG . . . . . . . . .L2 NV2 SERIES
NV2FG42BSG . . . . . . . . .L2 NV2 SERIES
NV2FG42XHG . . . . . . . . .L2 NV2 SERIES
NV2FG42XSG . . . . . . . . .L2 NV2 SERIES
NV2GG . . . . . . . . . . . . . .L3 NV2 SERIES
NV2IG15 . . . . . . . . . . . . .L3 NV2 SERIES
NV2IG15AHG . . . . . . . . .L2 NV2 SERIES
NV2IG15ASG . . . . . . . . .L2 NV2 SERIES
NV2IG15BHG . . . . . . . . .L2 NV2 SERIES
NV2IG15BSG . . . . . . . . .L2 NV2 SERIES
NV2IG15XHG . . . . . . . . .L2 NV2 SERIES
NV2IG15XSG . . . . . . . . .L2 NV2 SERIES
NV2MG . . . . . . . . . . . . . .L3 NV2 SERIES
NV2XG . . . . . . . . . . . . . .L3 NV2 SERIES
NVEXTG . . . . . . . . . . . . .L3 NV2 SERIES
NVPFSERIES................................L15
NVPISERIES ................................L15
NVPSD12 . . . . . . . . . . . .L3 NV2 SERIES
NWPSERIES ...........................L206-207
NWP-DECAL01 . . . . .L207 NWP SERIES
NWP-DECAL02 . . . . .L207 NWP SERIES
NWP-DECAL03 . . . . .L207 NWP SERIES
NWP-DECAL04 . . . . .L207 NWP SERIES
NWP-DECAL05 . . . . .L207 NWP SERIES
NWP-DECAL06 . . . . .L207 NWP SERIES
NWP-DECAL07 . . . . .L207 NWP SERIES
NWP-DECAL08 . . . . .L207 NWP SERIES
NWP-DECAL09 . . . . .L207 NWP SERIES
NWP-DECAL10 . . . . .L207 NWP SERIES
NWP-DECAL11 . . . . .L207 NWP SERIES
NWP-DECAL12 . . . . .L207 NWP SERIES
NWP-EXIT-SIGN . . . . .L207 NWP SERIES
NWP-KFBP7 . . . . . . . .L207 NWP SERIES
NWP-LENSONLY . . . .L207 NWP SERIES
OC-0 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-0M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-1 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-1M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-2 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-2M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-3 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-3M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-4 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-4M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-5 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-5M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-6 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-6M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-7 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-7M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-8 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-8M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-9 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OC-9M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OE-1 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OE-1M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OE-2 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OE-2M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OE-3 . . . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OE-3M . . . . . . . . . . . . .F15 O/DURALOY 5 SERIES
OL-10 . . . . . . . . . . .F19,22 O/DURALOY 5 SERIES
OL-10CM . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-10M . . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-20 . . . . . . . . . . .F19,22 O/DURALOY 5 SERIES
OL-20CM . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-20M . . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-30 . . . . . . . . . . .F19,22 O/DURALOY 5 SERIES
OL-30CM . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-30M . . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-450 . . . . . . . . . .F19,22 O/DURALOY 5 SERIES
OL-45CM . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-45M . . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-45-RG . . . . . . . .F19,22 O/DURALOY 5 SERIES
OL-45-VG . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-60 . . . . . . . . . . .F19,22 O/DURALOY 5 SERIES
OL-60CM . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-60M . . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-6-RG . . . . . . . . .F19,22 O/DURALOY 5 SERIES
OL-6-VG . . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-780 . . . . . . . . . .F19,22 O/DURALOY 5 SERIES
OL-78CM . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-78M . . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-78-RG . . . . . . . .F19,22 O/DURALOY 5 SERIES
OL-78-VG . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-900 . . . . . . . . . .F19,22 O/DURALOY 5 SERIES
OL-90CM . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-90M . . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OL-90-RG . . . . . . . .F19,22 O/DURALOY 5 SERIES
OL-90-VG . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OLB-0 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-0M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-1 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-1M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-2 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-2M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-3 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-3M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-4 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-4M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-5 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-5M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-6 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-6M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-7 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-7M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-8 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-8M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-9 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLB-9M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLK-1RG . . . . . . . . .F19,22 O/DURALOY 5 SERIES
OLK-1VG . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OLK-2RG . . . . . . . . .F19,22 O/DURALOY 5 SERIES
OLK-2VG . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OLK-3RG . . . . . . . . .F19,22 O/DURALOY 5 SERIES
OLK-3VG . . . . . . . . . . .F19 O/DURALOY 5 SERIES
OLL-0 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-0M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-1 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-1M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-2 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-2M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-3 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-3M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-4 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-4M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-5 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-5M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-6 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-6M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-7 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-7M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-8 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-8M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-9 . . . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLL-9M . . . . . . . . . . . .F16 O/DURALOY 5 SERIES
OLR-0 . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-0M . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-1 . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-1M . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-2 . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-2M . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-3 . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-3M . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-4 . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-4M . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-5 . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-5M . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-6 . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-6M . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-7 . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-7M . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-8 . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-8M . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-9 . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OLR-9M . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-0 . . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-0M . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-1 . . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-1M . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-2 . . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-2M . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-3 . . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-3M . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-4 . . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-4M . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-5 . . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-5M . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-6 . . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-6M . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-7 . . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-7M . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-8 . . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-8M . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-9 . . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OT-9M . . . . . . . . . . . . . .F17 O/DURALOY 5 SERIES
OTA-1 . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTA-1M . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTA-2 . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTA-2M . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTA-3M . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTB-1 . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTB-1M . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTB-2 . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTB-2M . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTB-3 . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTB-3M . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTB-4 . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTB-4M . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTB-5 . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTB-5M . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTB-6 . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OTB-6M . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OX-1 . . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OX-1M . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OX-2 . . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OX-2M . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OX-3 . . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OX-3M . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OX-4 . . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OX-4M . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OX-5 . . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OX-5M . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OX-6 . . . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
OX-6M . . . . . . . . . . . . .F18 O/DURALOY 5 SERIES
PCC050 . . . . . . . . . . . .F86 PCC SERIES
PCC075 . . . . . . . . . . . .F86 PCC SERIES
PCC100 . . . . . . . . . . . .F86 PCC SERIES
PCC125 . . . . . . . . . . . .F86 PCC SERIES
PCC150 . . . . . . . . . . . .F86 PCC SERIES
PCC200 . . . . . . . . . . . .F86 PCC SERIES
PCC250 . . . . . . . . . . . .F86 PCC SERIES
PCC300 . . . . . . . . . . . .F86 PCC SERIES
PCC350 . . . . . . . . . . . .F86 PCC SERIES
PCC400 . . . . . . . . . . . .F86 PCC SERIES
PF-16 . . . . . . . . . . . . . .F48 ENY/EYS/EY/EYD SERIES
PF-2 . . . . . . . . . . . . . . .F48 ENY/EYS/EY/EYD SERIES
PF-4 . . . . . . . . . . . . . . .F48 ENY/EYS/EY/EYD SERIES
PGPS . . . . . . . . . . . . .L195 KWP SERIES
PGWG . . . . . . . . . . . . .L195 KWP SERIES
PL-7 . . . . . . . . . . . . . . .F42 PL SERIES
PLUG1 . . . . . . . . . . . . .F63 PLUG SERIES
PLUG10 . . . . . . . . . . . .F63 PLUG SERIES
PLUG10-SQ . . . . . . . . .F63 PLUG SERIES
PLUG1-SQ . . . . . . . . . .F63 PLUG SERIES
PLUG2 . . . . . . . . . . . . .F63 PLUG SERIES
PLUG2-SQ . . . . . . . . . .F63 PLUG SERIES
PLUG3 . . . . . . . . . . . . .F63 PLUG SERIES
PLUG375 . . . . . . . . . . .F63 PLUG SERIES
PLUG3-SQ . . . . . . . . . .F63 PLUG SERIES
PLUG4 . . . . . . . . . . . . .F63 PLUG SERIES
PLUG4-SQ . . . . . . . . . .F63 PLUG SERIES
PLUG5 . . . . . . . . . . . . .F63 PLUG SERIES
PLUG5-SQ . . . . . . . . . .F63 PLUG SERIES
PLUG6 . . . . . . . . . . . . .F63 PLUG SERIES
PLUG6-SQ . . . . . . . . . .F63 PLUG SERIES
PLUG7 . . . . . . . . . . . . .F63 PLUG SERIES
PLUG7-SQ . . . . . . . . . .F63 PLUG SERIES
PLUG8 . . . . . . . . . . . . .F63 PLUG SERIES
PLUG8-SQ . . . . . . . . . .F63 PLUG SERIES
PLUG9 . . . . . . . . . . . . .F63 PLUG SERIES
PLUG9-SQ . . . . . . . . . .F63 PLUG SERIES
PVLV . . . . . . . . . . . . . .L195 KWP SERIES
QL-1505K . . . . . . . . . .L186 QL SERIES
QL-1505K-WQ . . . . . .L186 QL SERIES
QL-15G . . . . . . . . . . . .L186 QL SERIES
QL-500K . . . . . . . . . . .L186 QL SERIES
QL-500K-WQ . . . . . . .L186 QL SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
INTRODUCTION
NUMERIC INDEX
INTRODUCTION
NUMERIC INDEX
N10
QL-5G . . . . . . . . . . . . .L186 QL SERIES
QL-TB . . . . . . . . . . . . .L186 QL SERIES
R-10 . . . . . . . . . . . . . . .F65 R SERIES
R-106 . . . . . . . . . . . . . .F65 R SERIES
R-107 . . . . . . . . . . . . . .F65 R SERIES
R-108 . . . . . . . . . . . . . .F65 R SERIES
R-109 . . . . . . . . . . . . . .F65 R SERIES
R-20 . . . . . . . . . . . . . . .F65 R SERIES
R-21 . . . . . . . . . . . . . . .F65 R SERIES
R-30 . . . . . . . . . . . . . . .F65 R SERIES
R-31 . . . . . . . . . . . . . . .F65 R SERIES
R-32 . . . . . . . . . . . . . . .F65 R SERIES
R-41 . . . . . . . . . . . . . . .F65 R SERIES
R-42 . . . . . . . . . . . . . . .F65 R SERIES
R-43 . . . . . . . . . . . . . . .F65 R SERIES
R-51 . . . . . . . . . . . . . . .F65 R SERIES
R-52 . . . . . . . . . . . . . . .F65 R SERIES
R-53 . . . . . . . . . . . . . . .F65 R SERIES
R-54 . . . . . . . . . . . . . . .F65 R SERIES
R-61 . . . . . . . . . . . . . . .F65 R SERIES
R-62 . . . . . . . . . . . . . . .F65 R SERIES
R-63 . . . . . . . . . . . . . . .F65 R SERIES
R-64 . . . . . . . . . . . . . . .F65 R SERIES
R-65 . . . . . . . . . . . . . . .F65 R SERIES
R-73 . . . . . . . . . . . . . . .F65 R SERIES
R-74 . . . . . . . . . . . . . . .F65 R SERIES
R-75 . . . . . . . . . . . . . . .F65 R SERIES
R-76 . . . . . . . . . . . . . . .F65 R SERIES
R-85 . . . . . . . . . . . . . . .F65 R SERIES
R-86 . . . . . . . . . . . . . . .F65 R SERIES
R-87 . . . . . . . . . . . . . . .F65 R SERIES
R-97 . . . . . . . . . . . . . . .F65 R SERIES
R-98 . . . . . . . . . . . . . . .F65 R SERIES
RACC050 . . . . . . . . . . .F86 RACC SERIES
RACC075 . . . . . . . . . . .F86 RACC SERIES
RACC100 . . . . . . . . . . .F86 RACC SERIES
RACC125 . . . . . . . . . . .F86 RACC SERIES
RACC150 . . . . . . . . . . .F86 RACC SERIES
RACC200 . . . . . . . . . . .F86 RACC SERIES
RACC250 . . . . . . . . . . .F86 RACC SERIES
RACC300 . . . . . . . . . . .F86 RACC SERIES
RACC350 . . . . . . . . . . .F86 RACC SERIES
RACC400 . . . . . . . . . . .F86 RACC SERIES
RE20S . . . . . . . . . . . . . .F65 RE SERIES
RE21S . . . . . . . . . . . . . .F65 RE SERIES
RE30S . . . . . . . . . . . . . .F65 RE SERIES
RE31S . . . . . . . . . . . . . .F65 RE SERIES
RE32S . . . . . . . . . . . . . .F65 RE SERIES
RE41S . . . . . . . . . . . . . .F65 RE SERIES
RE42S . . . . . . . . . . . . . .F65 RE SERIES
RE43S . . . . . . . . . . . . . .F65 RE SERIES
RE51S . . . . . . . . . . . . . .F65 RE SERIES
RE52S . . . . . . . . . . . . . .F65 RE SERIES
RE53S . . . . . . . . . . . . . .F65 RE SERIES
RE54S . . . . . . . . . . . . . .F65 RE SERIES
RE61S . . . . . . . . . . . . . .F65 RE SERIES
RE62S . . . . . . . . . . . . . .F65 RE SERIES
RE63S . . . . . . . . . . . . . .F65 RE SERIES
RE64S . . . . . . . . . . . . . .F65 RE SERIES
RE65S . . . . . . . . . . . . . .F65 RE SERIES
SC-1 LB . . . . . . . . . . . .F48 ENY/EYS/EY/EYD SERIES
SC-4 OZ . . . . . . . . . . . .F48 ENY/EYS/EY/EYD SERIES
SC-5 LB . . . . . . . . . . . .F48 ENY/EYS/EY/EYD SERIES
SC-8 OZ . . . . . . . . . . . .F48 ENY/EYS/EY/EYD SERIES
SLB-1 . . . . . . . . . . . . . .F27 SLB SERIES
SLB-2 . . . . . . . . . . . . . .F27 SLB SERIES
SLB-3 . . . . . . . . . . . . . .F27 SLB SERIES
SLB-4 . . . . . . . . . . . . . .F27 SLB SERIES
SLB-5 . . . . . . . . . . . . . .F27 SLB SERIES
SLB-6 . . . . . . . . . . . . . .F27 SLB SERIES
SLB-7 . . . . . . . . . . . . . .F27 SLB SERIES
SLBM-4 . . . . . . . . . . . .F27 SLBM SERIES
SLBM-6 . . . . . . . . . . . .F27 SLBM SERIES
SOLB-0 . . . . . . . . . . . . .F27 SOLB SERIES
SOLB-8 . . . . . . . . . . . . .F27 SOLB SERIES
SOLB-9 . . . . . . . . . . . . .F27 SOLB SERIES
STFB-0 . . . . . . . . . . . . .F30 STFB SERIES
STFB-2 . . . . . . . . . . . . .F30 STFB SERIES
STFB-3 . . . . . . . . . . . . .F30 STFB SERIES
STFB-4 . . . . . . . . . . . . .F30 STFB SERIES
STFB-5 . . . . . . . . . . . . .F30 STFB SERIES
STFB-6 . . . . . . . . . . . . .F30 STFB SERIES
STFB-7 . . . . . . . . . . . . .F30 STFB SERIES
STFB-8 . . . . . . . . . . . . .F30 STFB SERIES
SWB-1 . . . . . . . . . . . . .C19 SWB SERIES
SWB-10 . . . . . . . . . . . .C19 SWB SERIES
SWB-11 . . . . . . . . . . . .C19 SWB SERIES
SWB-12 . . . . . . . . . . . .C19 SWB SERIES
SWB-13 . . . . . . . . .C19,37 SWB SERIES
SWB-14 . . . . . . . . .C19,37 SWB SERIES
SWB-15 . . . . . . . . . . . .C37 SWB SERIES
SWB-16 . . . . . . . . . . . .C37 SWB SERIES
SWB-17 . . . . . . . . . . . .C19 SWB SERIES
SWB-18 . . . . . . . . . . . .C19 SWB SERIES
SWB-19 . . . . . . . . . . . .C19 SWB SERIES
SWB-2 . . . . . . . . . . . . .C19 SWB SERIES
SWB-20 . . . . . . . . . . . .C19 SWB SERIES
SWB-21 . . . . . . . . . . . .C19 SWB SERIES
SWB-3 . . . . . . . . . . . . .C19 SWB SERIES
SWB-32 . . . . . . . . . . . .C19 SWB SERIES
SWB-33 . . . . . . . . . . . .C19 SWB SERIES
SWB-34 . . . . . . . . . . . .C19 SWB SERIES
SWB-38 . . . . . . . . . . . .C19 SWB SERIES
SWB-4 . . . . . . . . . . . . .C19 SWB SERIES
SWB-42 . . . . . . . . . . . .C19 SWB SERIES
SWB-45 . . . . . . . . . . . .C19 SWB SERIES
SWB-48 . . . . . . . . . . . .C19 SWB SERIES
SWB-49 . . . . . . . . . . . .C19 SWB SERIES
SWB-5 . . . . . . . . . . . . .C19 SWB SERIES
SWB-6 . . . . . . . . . . . . .C19 SWB SERIES
SWB-7 . . . . . . . . . . . . .C19 SWB SERIES
SWB-8 . . . . . . . . . . . . .C19 SWB SERIES
SWB-83 . . . . . . . . . . . .C37 SWB SERIES
SWB-9 . . . . . . . . . . . . .C19 SWB SERIES
SWBC-13 . . . . . . . . . . .C37 SWBC SERIES
SWBC-14 . . . . . . . . . . .C37 SWBC SERIES
SWBC-15 . . . . . . . . . . .C37 SWBC SERIES
SWBC-16 . . . . . . . . . . .C37 SWBC SERIES
SWBC-83 . . . . . . . . . . .C37 SWBC SERIES
SWITCHRACK ASSEMBLIES . . . . . . . . . . . . . . . . . .DE26
SWZ60-050NPT . . . . . .F85 SWZ SERIES
SWZ60-075NPT . . . . . .F85 SWZ SERIES
SWZ60-100NPT . . . . . .F85 SWZ SERIES
SWZ60-125NPT . . . . . .F85 SWZ SERIES
SWZ60-150NPT . . . . . .F85 SWZ SERIES
SWZ60-200NPT . . . . . .F85 SWZ SERIES
SWZ60-250NPT . . . . . .F85 SWZ SERIES
SWZ60-300NPT . . . . . .F85 SWZ SERIES
SWZ60-350NPT . . . . . .F85 SWZ SERIES
T107 . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T107SA . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T17 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T17SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T18 . . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
T27 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T27SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T28 . . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
T37 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T37SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T38 . . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
T448 . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
T47 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T47SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T57 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T57SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T58 . . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
T67 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T67SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T68 . . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
T77 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T77SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T78 . . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
T87 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T87SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T88 . . . . . . . . . . . . . . . .F12 DURALOY 8 SERIES
T97 . . . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
T97SA . . . . . . . . . . . . . . .F4 DURALOY 7 SERIES
TA17 . . . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TA17SA . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TA27 . . . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TA27SA . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TA37 . . . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TA37SA . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TA47 . . . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TA47SA . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TA57 . . . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TA57SA . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TA67 . . . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TA67SA . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB17 . . . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB17SA . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB18 . . . . . . . . . . . . . . .F13 DURALOY 8 SERIES
TB27 . . . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB27SA . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB28 . . . . . . . . . . . . . . .F13 DURALOY 8 SERIES
TB37 . . . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB37SA . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB38 . . . . . . . . . . . . . . .F13 DURALOY 8 SERIES
TB448 . . . . . . . . . . . . . .F13 DURALOY 8 SERIES
TB47 . . . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB47SA . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB57 . . . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB57SA . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB58 . . . . . . . . . . . . . . .F13 DURALOY 8 SERIES
TB67 . . . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB67SA . . . . . . . . . . . . . .F5 DURALOY 7 SERIES
TB68 . . . . . . . . . . . . . . .F13 DURALOY 8 SERIES
TBWE-12 . . . . . . . . . . .E22 TBWE SERIES
TBWE-15 . . . . . . . . . . .E22 TBWE SERIES
TBWE-18 . . . . . . . . . . .E22 TBWE SERIES
TBWE-21 . . . . . . . . . . .E22 TBWE SERIES
TBWE-24 . . . . . . . . . . .E22 TBWE SERIES
TBWE-27 . . . . . . . . . . .E22 TBWE SERIES
TBWE-3 . . . . . . . . . . . .E22 TBWE SERIES
TBWE-30 . . . . . . . . . . .E22 TBWE SERIES
TBWE-33 . . . . . . . . . . .E22 TBWE SERIES
TBWE-36 . . . . . . . . . . .E22 TBWE SERIES
TBWE-39 . . . . . . . . . . .E22 TBWE SERIES
TBWE-42 . . . . . . . . . . .E22 TBWE SERIES
TBWE-45 . . . . . . . . . . .E22 TBWE SERIES
TBWE-48 . . . . . . . . . . .E22 TBWE SERIES
TBWE-51 . . . . . . . . . . .E22 TBWE SERIES
TBWE-54 . . . . . . . . . . .E22 TBWE SERIES
TBWE-57 . . . . . . . . . . .E22 TBWE SERIES
TBWE-6 . . . . . . . . . . . .E22 TBWE SERIES
TBWE-60 . . . . . . . . . . .E22 TBWE SERIES
TBWE-9 . . . . . . . . . . . .E22 TBWE SERIES
TEB SERIES . . . . . . . . . .E4 TEF/TEB SERIES
TEF SERIES . . . . . . . . . . .E4 TEF/TEB SERIES
TWCL-1 . . . . . . . . . . . .F29 TWCL SERIES
TWCL-2 . . . . . . . . . . . .F29 TWCL SERIES
TWOC-0CG . . . . . . . . .F20 K-PAK SERIES
TWOC-7CG . . . . . . . . .F20 K-PAK SERIES
TWOC-8CG . . . . . . . . .F20 K-PAK SERIES
TWOC-9CG . . . . . . . . .F20 K-PAK SERIES
TWOLB-0CG . . . . . . . . .F20 K-PAK SERIES
TWOLB-7CG . . . . . . . . .F20 K-PAK SERIES
TWOLB-8CG . . . . . . . . .F20 K-PAK SERIES
TWOLB-9CG . . . . . . . . .F20 K-PAK SERIES
TWOLL-0CG . . . . . . . . .F21 K-PAK SERIES
TWOLL-7CG . . . . . . . . .F21 K-PAK SERIES
TWOLL-8CG . . . . . . . . .F21 K-PAK SERIES
TWOLL-9CG . . . . . . . . .F21 K-PAK SERIES
TWOLR-0CG . . . . . . . . .F21 K-PAK SERIES
TWOLR-7CG . . . . . . . . .F21 K-PAK SERIES
TWOLR-8CG . . . . . . . . .F21 K-PAK SERIES
TWOLR-9CG . . . . . . . . .F21 K-PAK SERIES
TWOT-0CG . . . . . . . . . .F22 K-PAK SERIES
TWOT-7CG . . . . . . . . . .F22 K-PAK SERIES
TWOT-8CG . . . . . . . . . .F22 K-PAK SERIES
TWOT-9CG . . . . . . . . . .F22 K-PAK SERIES
UFGI152C1 . . . . . . . .PR27 UGFI SERIES
UFGI152C2 . . . . . . . .PR27 UGFI SERIES
UFGI152C3 . . . . . . . .PR27 UGFI SERIES
UGFI152AD . . . . . . . .PR27 UGFI SERIES
UGFI15AD . . . . . . . . .PR27 UGFI SERIES
UGFI15C1 . . . . . . . . .PR27 UGFI SERIES
UGFI15C2 . . . . . . . . .PR27 UGFI SERIES
UGFI15C3 . . . . . . . . .PR27 UGFI SERIES
UGFI202AD . . . . . . . .PR27 UGFI SERIES
UGFI202C1 . . . . . . . .PR27 UGFI SERIES
UGFI202C2 . . . . . . . .PR27 UGFI SERIES
UGFI202C3 . . . . . . . .PR27 UGFI SERIES
UGFI20AD . . . . . . . . .PR27 UGFI SERIES
UGFI20C1 . . . . . . . . .PR27 UGFI SERIES
UGFI20C2 . . . . . . . . .PR27 UGFI SERIES
UGFI20C3 . . . . . . . . .PR27 UGFI SERIES
UGMG . . . . . . . . . . . .PR26 UG SERIES
UGP-15231 . . .PR22,24,25 UG SERIES
UGP-15231QW . . . . .PR22 UG SERIES
UGP-15232 . . .PR22,24,25 UG SERIES
UGP-15232QW . . . . .PR22 UG SERIES
UGP-20231 . . .PR22,24,25 UG SERIES
UGP-20231QW . . . . .PR22 UG SERIES
UGP-20232 . . .PR22,24,25 UG SERIES
UGP-20232QW . . . . .PR22 UG SERIES
UGR10-20231 . . . . . .PR23 UG SERIES
UGR10-20232 . . . . . .PR23 UG SERIES
UGR10C-15231 . . . . .PR23 UG SERIES
UGR10C-15232 . . . . .PR23 UG SERIES
UGR11-20231 . . . . . .PR23 UG SERIES
UGR11-20232 . . . . . .PR23 UG SERIES
UGR11C-15231 . . . . .PR23 UG SERIES
UGR11C-15232 . . . . .PR23 UG SERIES
UGR1-20231 . . . . . . .PR23 UG SERIES
UGR1-20232 . . . . . . .PR23 UG SERIES
UGR12-20231 . . . . . .PR23 UG SERIES
UGR12-20232 . . . . . .PR23 UG SERIES
UGR12C-15231 . . . . .PR23 UG SERIES
UGR12C-15232 . . . . .PR23 UG SERIES
UGR1C-15231 . . . . . .PR23 UG SERIES
UGR1C-15232 . . . . . .PR23 UG SERIES
UGR2-20231 . . . . . . .PR23 UG SERIES
UGR2-20232 . . . . . . .PR23 UG SERIES
UGR2C-15231 . . . . . .PR23 UG SERIES
UGR2C-15232 . . . . . .PR23 UG SERIES
UGR3-20231 . . . . . . .PR23 UG SERIES
UGR3-20232 . . . . . . .PR23 UG SERIES
UGR3C-15231 . . . . . .PR23 UG SERIES
UGR3C-15232 . . . . . .PR23 UG SERIES
UGR4-20231 . . . . . . .PR23 UG SERIES
UGR4-20232 . . . . . . .PR23 UG SERIES
UGR4C-15231 . . . . . .PR23 UG SERIES
UGR4C-15232 . . . . . .PR23 UG SERIES
UGR5-20231 . . . . . . .PR23 UG SERIES
UGR5-20232 . . . . . . .PR23 UG SERIES
UGR5C-15231 . . . . . .PR23 UG SERIES
UGR5C-15232 . . . . . .PR23 UG SERIES
UGR6-20231 . . . . . . .PR23 UG SERIES
UGR6-20232 . . . . . . .PR23 UG SERIES
UGR6C-15231 . . . . . .PR23 UG SERIES
UGR6C-15232 . . . . . .PR23 UG SERIES
UGR7-20231 . . . . . . .PR23 UG SERIES
UGR7-20232 . . . . . . .PR23 UG SERIES
UGR7C-15231 . . . . . .PR23 UG SERIES
UGR7C-15232 . . . . . .PR23 UG SERIES
UGR8-20231 . . . . . . .PR23 UG SERIES
UGR8-20232 . . . . . . .PR23 UG SERIES
UGR8C-15231 . . . . . .PR23 UG SERIES
UGR8C-15232 . . . . . .PR23 UG SERIES
UGR9-20231 . . . . . . .PR23 UG SERIES
UGR9-20232 . . . . . . .PR23 UG SERIES
UGR9C-15231 . . . . . .PR23 UG SERIES
UGR9C-15232 . . . . . .PR23 UG SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
INTRODUCTION
NUMERIC INDEX N11
UGRA-20231 . . . . . . .PR26 UG SERIES
UGRA-20232 . . . . . . .PR26 UG SERIES
UGRB1-20231 . . . . . .PR23 UG SERIES
UGRB1-20232 . . . . . .PR23 UG SERIES
UGRB1C-15231 . . . . .PR23 UG SERIES
UGRB1C-15232 . . . . .PR23 UG SERIES
UGRB2-20231 . . . . . .PR23 UG SERIES
UGRB2-20232 . . . . . .PR23 UG SERIES
UGRB2C-15231 . . . . .PR23 UG SERIES
UGRB2C-15232 . . . . .PR23 UG SERIES
UGRB3-20231 . . . . . .PR23 UG SERIES
UGRB3-20232 . . . . . .PR23 UG SERIES
UGRB3C-15231 . . . . .PR23 UG SERIES
UGRB3C-15232 . . . . .PR23 UG SERIES
UGRB4-20231 . . . . . .PR23 UG SERIES
UGRB4-20232 . . . . . .PR23 UG SERIES
UGRB4C-15231 . . . . .PR23 UG SERIES
UGRB4C-15232 . . . . .PR23 UG SERIES
UGRB5-20231 . . . . . .PR23 UG SERIES
UGRB5-20232 . . . . . .PR23 UG SERIES
UGRB5C-15231 . . . . .PR23 UG SERIES
UGRB5C-15232 . . . . .PR23 UG SERIES
UGRB6-20231 . . . . . .PR23 UG SERIES
UGRB6-20232 . . . . . .PR23 UG SERIES
UGRB6C-15231 . . . . .PR23 UG SERIES
UGRB6C-15232 . . . . .PR23 UG SERIES
UGRC-20231B . . . . . . .F24 UG SERIES
UGRC-20231F . . . . . . .F24 UG SERIES
UGRC-20232B . . . . . . .F24 UG SERIES
UGRC-20232F . . . . . . .F24 UG SERIES
UGRGF107 . . . . . . . . .PR26 UGRGF SERIES
UGRGF108 . . . . . . . . .PR26 UGRGF SERIES
UGRGF108-PL . . . . . .PR26 UGRGF SERIES
UGRGF109 . . . . . . . . .PR26 UGRGF SERIES
UGRGF109-PL . . . . . .PR26 UGRGF SERIES
UGRGF110 . . . . . . . . .PR26 UGRGF SERIES
UGRGF110-PL . . . . . .PR26 UGRGF SERIES
UGRGF111 . . . . . . . . .PR26 UGRGF SERIES
UGRGF111-PL . . . . . .PR26 UGRGF SERIES
UGRGF112 . . . . . . . . .PR26 UGRGF SERIES
UGRGF112-PL . . . . . .PR26 UGRGF SERIES
UGRO-20231 . . . . . . .PR23 UG SERIES
UGRO-20232 . . . . . . .PR23 UG SERIES
UGROC-15231 . . . . . .PR23 UG SERIES
UGROC-15232 . . . . . .PR23 UG SERIES
UGRP-20231B . . . . . .PR25 UG SERIES
UGRP-20231F . . . . . .PR25 UG SERIES
UGRP-20232B . . . . . .PR25 UG SERIES
UGRP-20232F . . . . . .PR25 UG SERIES
UNF0 . . . . . . . . . . . . . . .F61 UN SERIES
UNF1 . . . . . . . . . . . . . . .F61 UN SERIES
UNF2 . . . . . . . . . . . . . . .F61 UN SERIES
UNF3 . . . . . . . . . . . . . . .F61 UN SERIES
UNF4 . . . . . . . . . . . . . . .F61 UN SERIES
UNF5 . . . . . . . . . . . . . . .F61 UN SERIES
UNF6 . . . . . . . . . . . . . . .F61 UN SERIES
UNF7 . . . . . . . . . . . . . . .F61 UN SERIES
UNF8 . . . . . . . . . . . . . . .F61 UN SERIES
UNF9 . . . . . . . . . . . . . . .F61 UN SERIES
UNFL1 . . . . . . . . . . . . . .F62 UNF SERIES
UNFL2 . . . . . . . . . . . . . .F62 UNF SERIES
UNFL3 . . . . . . . . . . . . . .F62 UNF SERIES
UNFS1 . . . . . . . . . . . . .F62 UNF SERIES
UNFS2 . . . . . . . . . . . . .F62 UNF SERIES
UNFS3 . . . . . . . . . . . . .F62 UNF SERIES
UNY0 . . . . . . . . . . . . . .F61 UN SERIES
UNY1 . . . . . . . . . . . . . .F61 UN SERIES
UNY2 . . . . . . . . . . . . . .F61 UN SERIES
UNY3 . . . . . . . . . . . . . .F61 UN SERIES
UNY4 . . . . . . . . . . . . . .F61 UN SERIES
UNY5 . . . . . . . . . . . . . .F61 UN SERIES
UNY6 . . . . . . . . . . . . . .F61 UN SERIES
UNY7 . . . . . . . . . . . . . .F61 UN SERIES
UNY8 . . . . . . . . . . . . . .F61 UN SERIES
UNY9 . . . . . . . . . . . . . .F61 UN SERIES
UNYL1 . . . . . . . . . . . . .F62 UNY SERIES
UNYL2 . . . . . . . . . . . . .F62 UNY SERIES
UNYL3 . . . . . . . . . . . . .F62 UNY SERIES
UNYS1 . . . . . . . . . . . . .F62 UNY SERIES
UNYS2 . . . . . . . . . . . . .F62 UNY SERIES
UNYS3 . . . . . . . . . . . . .F62 UNY SERIES
VAG-100 . . . . . . . . . . . .L12 V SERIES
VAG-200 . . . . . . . . . . . .L12 V SERIES
VAMG-100 . . . . . . . . . .L12 V SERIES
VAMG-200 . . . . . . . . . .L12 V SERIES
VAMGP-100 . . . . . . . . .L12 V SERIES
VB-1 . . . . . . . . . . . . . . .L11 V SERIES
VB-2 . . . . . . . . . . . . . . .L11 V SERIES
VBA................L11 VSERIES
VBC-1 . . . . . . . . . . . . . .L11 V SERIES
VBC-2 . . . . . . . . . . . . . .L11 V SERIES
VBG-100 . . . . . . . . . . . .L12 V SERIES
VBGP-100 . . . . . . . . . . .L12 V SERIES
VBNB . . . . . . . . . . . . . .F43 VJ SERIES
VBNB . . . . . . . . . . . . . .L12 V SERIES
VBQ1023CH100 . . . .PR13 VBQ SERIES
VBQ1023CH50 . . . . .PR13 VBQ SERIES
VBQ1023CH70 . . . . .PR13 VBQ SERIES
VBQ1023CH90 . . . . .PR13 VBQ SERIES
VBQ1023CN100 . . . .PR13 VBQ SERIES
VBQ1023CN50 . . . . .PR13 VBQ SERIES
VBQ1023CN70 . . . . .PR13 VBQ SERIES
VBQ1023CN90 . . . . .PR13 VBQ SERIES
VBQ1023SH100 . . . .PR13 VBQ SERIES
VBQ1023SH50 . . . . . .PR13 VBQ SERIES
VBQ1023SH70 . . . . . .PR13 VBQ SERIES
VBQ1023SH90 . . . . . .PR13 VBQ SERIES
VBQ1023SN100 . . . .PR13 VBQ SERIES
VBQ1023SN50 . . . . . .PR13 VBQ SERIES
VBQ1023SN70 . . . . . .PR13 VBQ SERIES
VBQ1023SN90 . . . . . .PR13 VBQ SERIES
VBQ1034CH100 . . . .PR13 VBQ SERIES
VBQ1034CH50 . . . . .PR13 VBQ SERIES
VBQ1034CH70 . . . . .PR13 VBQ SERIES
VBQ1034CH90 . . . . .PR13 VBQ SERIES
VBQ1034CN100 . . . .PR13 VBQ SERIES
VBQ1034CN50 . . . . .PR13 VBQ SERIES
VBQ1034CN70 . . . . .PR13 VBQ SERIES
VBQ1034CN90 . . . . .PR13 VBQ SERIES
VBQ1034SH100 . . . .PR13 VBQ SERIES
VBQ1034SH50 . . . . . .PR13 VBQ SERIES
VBQ1034SH70 . . . . . .PR13 VBQ SERIES
VBQ1034SH90 . . . . . .PR13 VBQ SERIES
VBQ1034SN100 . . . .PR13 VBQ SERIES
VBQ1034SN50 . . . . . .PR13 VBQ SERIES
VBQ1034SN70 . . . . . .PR13 VBQ SERIES
VBQ1034SN90 . . . . . .PR13 VBQ SERIES
VBQ3023SN30 . . . . . .PR13 VBQ SERIES
VBQ3034SH30 . . . . . .PR13 VBQ SERIES
VBQ3034SN30 . . . . . .PR13 VBQ SERIES
VBQ6023CH100 . . . .PR13 VBQ SERIES
VBQ6023CH50 . . . . .PR13 VBQ SERIES
VBQ6023CH60 . . . . .PR13 VBQ SERIES
VBQ6023CH70 . . . . .PR13 VBQ SERIES
VBQ6023CH90 . . . . .PR13 VBQ SERIES
VBQ6023CN100 . . . .PR13 VBQ SERIES
VBQ6023CN50 . . . . .PR13 VBQ SERIES
VBQ6023CN60 . . . . .PR13 VBQ SERIES
VBQ6023CN70 . . . . .PR13 VBQ SERIES
VBQ6023CN90 . . . . .PR13 VBQ SERIES
VBQ6023SH100 . . . .PR13 VBQ SERIES
VBQ6023SH50 . . . . . .PR13 VBQ SERIES
VBQ6023SH60 . . . . . .PR13 VBQ SERIES
VBQ6023SH70 . . . . . .PR13 VBQ SERIES
VBQ6023SH90 . . . . . .PR13 VBQ SERIES
VBQ6023SN100 . . . .PR13 VBQ SERIES
VBQ6023SN50 . . . . . .PR13 VBQ SERIES
VBQ6023SN60 . . . . . .PR13 VBQ SERIES
VBQ6023SN70 . . . . . .PR13 VBQ SERIES
VBQ6023SN90 . . . . . .PR13 VBQ SERIES
VBQ6034CH100 . . . .PR13 VBQ SERIES
VBQ6034CH50 . . . . .PR13 VBQ SERIES
VBQ6034CH60 . . . . .PR13 VBQ SERIES
VBQ6034CH70 . . . . .PR13 VBQ SERIES
VBQ6034CH90 . . . . .PR13 VBQ SERIES
VBQ6034CN100 . . . .PR13 VBQ SERIES
VBQ6034CN50 . . . . .PR13 VBQ SERIES
VBQ6034CN60 . . . . .PR13 VBQ SERIES
VBQ6034CN70 . . . . .PR13 VBQ SERIES
VBQ6034CN90 . . . . .PR13 VBQ SERIES
VBQ6034SH100 . . . .PR13 VBQ SERIES
VBQ6034SH50 . . . . . .PR13 VBQ SERIES
VBQ6034SH60 . . . . . .PR13 VBQ SERIES
VBQ6034SH70 . . . . . .PR13 VBQ SERIES
VBQ6034SH90 . . . . . .PR13 VBQ SERIES
VBQ6034SN100 . . . .PR13 VBQ SERIES
VBQ6034SN50 . . . . . .PR13 VBQ SERIES
VBQ6034SN60 . . . . . .PR13 VBQ SERIES
VBQ6034SN70 . . . . . .PR13 VBQ SERIES
VBQ6034SN90 . . . . . .PR13 VBQ SERIES
VCG-100 . . . . . . . . . .L3,12 NV2 SERIES
VCG-200 . . . . . . . . . . . .L12 V SERIES
VCG-500 . . . . . . . . . . . .L12 V SERIES
VCGP-100 . . . . . . . . .L3,12 NV2 SERIES
VCGP-200 . . . . . . . . . .L12 V SERIES
VCGP-500 . . . . . . . . . .L12 V SERIES
VCGPT-100 . . . . . . . . .L12 V SERIES
VCR16R304 . . . . . . . .PR17 VCR SERIES
VCR16R306 . . . . . . . .PR17 VCR SERIES
VCR16R307 . . . . . . . .PR17 VCR SERIES
VCR16R405 . . . . . . . .PR17 VCR SERIES
VCR16R407 . . . . . . . .PR17 VCR SERIES
VCR16R409 . . . . . . . .PR17 VCR SERIES
VCR16R505 . . . . . . . .PR17 VCR SERIES
VCR16R507 . . . . . . . .PR17 VCR SERIES
VCR16R509 . . . . . . . .PR17 VCR SERIES
VCR32R405 . . . . . . . .PR17 VCR SERIES
VCR32R407 . . . . . . . .PR17 VCR SERIES
VCR32R409 . . . . . . . .PR17 VCR SERIES
VCR32R505 . . . . . . . .PR17 VCR SERIES
VCR32R507 . . . . . . . .PR17 VCR SERIES
VCR32R509 . . . . . . . .PR17 VCR SERIES
VD-4 . . . . . . . . . . . . . . .L11 V SERIES
VD-410G . . . . . . . . . . . . .L8 V SERIES
VD-410GG . . . . . . . . . . .L8 V SERIES
VD-410GGPX . . . . . . . .L10 V SERIES
VD-420G . . . . . . . . . . . . .L8 V SERIES
VD-420GG . . . . . . . . . . .L8 V SERIES
VD-420GGPX . . . . . . . .L10 V SERIES
VE3BSERIES ...........................L199-204
VE3B0013E10 . . . . . .L202 VE3B SERIES
VE3B0026E10 . . . . . .L202 VE3B SERIES
VE3B1313E01 . . . . . .L202 VE3B SERIES
VE3B2613E01 . . . . . .L202 VE3B SERIES
VE3B2626E01 . . . . . .L202 VE3B SERIES
VE3QSERIES...........................L199-204
VE3Q0018E30 . . . . . .L202 VE3Q SERIES
VE3Q0026E30 . . . . . .L202 VE3Q SERIES
VE3Q0032E30 . . . . . .L202 VE3Q SERIES
VE3Q0036E30 . . . . . .L202 VE3Q SERIES
VE3Q0042E30 . . . . . .L202 VE3Q SERIES
VE3Q0052E30 . . . . . .L202 VE3Q SERIES
VE3Q0064E30 . . . . . .L202 VE3Q SERIES
VE3Q0084E30 . . . . . .L202 VE3Q SERIES
VE3Q1818E30 . . . . . .L202 VE3Q SERIES
VE3Q2626E30 . . . . . .L202 VE3Q SERIES
VE3Q3232E30 . . . . . .L202 VE3Q SERIES
VE3Q3618E30 . . . . . .L202 VE3Q SERIES
VE3Q3636E30 . . . . . .L202 VE3Q SERIES
VE3Q4242E30 . . . . . .L202 VE3Q SERIES
VE3Q5226E30 . . . . . .L202 VE3Q SERIES
VE3Q5252E30 . . . . . .L202 VE3Q SERIES
VE3Q6432E30 . . . . . .L202 VE3Q SERIES
VE3Q6464E30 . . . . . .L202 VE3Q SERIES
VE3Q8442E30 . . . . . .L202 VE3Q SERIES
VE3Q8484E30 . . . . . .L202 VE3Q SERIES
VE4BSERIES ...........................L199-204
VE4QSERIES...........................L199-204
VEXA100B . . . . . . . . .L204
VEXA400 . . . . . . . . . . .L204
VFBG-110 . . . . . . . . . . . .L8 V SERIES
VFBG-1-100 . . . . . . . . . .L8 V SERIES
VFBG-120 . . . . . . . . . . . .L8 V SERIES
VFBG-1-200 . . . . . . . . . .L8 V SERIES
VFBG-210 . . . . . . . . . . . .L8 V SERIES
VFBG-2-100 . . . . . . . . . .L8 V SERIES
VFBG-220 . . . . . . . . . . . .L8 V SERIES
VFBG-2-200 . . . . . . . . . .L8 V SERIES
VFBGG-110 . . . . . . . . . .L8 V SERIES
VFBGG-1-100 . . . . . . . . .L8 V SERIES
VFBGG-1-100PX . . . . .L10 V SERIES
VFBGG-120 . . . . . . . . . .L8 V SERIES
VFBGG-1-200 . . . . . . . . .L8 V SERIES
VFBGG-1-200PX . . . . .L10 V SERIES
VFBGG-210 . . . . . . . . . .L8 V SERIES
VFBGG-2-100 . . . . . . . . .L8 V SERIES
VFBGG-2-100PX . . . . .L10 V SERIES
VFBGG-220 . . . . . . . . . .L8 V SERIES
VFBGG-2-200 . . . . . . . . .L8 V SERIES
VFBGG-2-200PX . . . . .L10 V SERIES
VFC-100 . . . . . . . . . . . .L11 V SERIES
VFC-200 . . . . . . . . . . . .L11 V SERIES
VFCA-100 . . . . . . . . . . . .L7 V SERIES
VFCA-200 . . . . . . . . . . . .L7 V SERIES
VFCAG-100 . . . . . . . . . .L7 V SERIES
VFCAG-200 . . . . . . . . . .L7 V SERIES
VFL ................L11 VSERIES
VFPS . . . . . . . . . . . . . . .L11 V SERIES
VG-2 . . . . . . . . . . . . . .L220 FIXTURE HANGERS
VGA-1 . . . . . . . . . .L11,220 V SERIES
VGA-2 . . . . . . . . . .L11,220 V SERIES
VGC-1 . . . . . . . . . .L11,220 V SERIES
VGC-2 . . . . . . . . . .L11,220 V SERIES
VGG-100 . . . . . . . . . . . .L12 V SERIES
VGG-200 . . . . . . . . . . . .L12 V SERIES
VGGP-100 . . . . . . . . . .L12 V SERIES
VGGP-200 . . . . . . . . . .L12 V SERIES
VGH-1 . . . . . . . . . .L11,220 V SERIES
VGH-2 . . . . . . . . . .L11,220 V SERIES
VGX-1 . . . . . . . . . .L11,220 V SERIES
VGX-2 . . . . . . . . . .L11,220 V SERIES
VJ37 . . . . . . . . . . . . . . .PR8 VERSAMATE SERIES
VJ47 . . . . . . . . . . . . . . .PR8 VERSAMATE SERIES
VJ57 . . . . . . . . . . . . . . .PR8 VERSAMATE SERIES
VJ58 . . . . . . . . . . . . . . .PR9 VERSAMATE SERIES
VJ67 . . . . . . . . . . . . . . .PR8 VERSAMATE SERIES
VJ68 . . . . . . . . . . . . . . .PR9 VERSAMATE SERIES
VJ78 . . . . . . . . . . . . . . .PR9 VERSAMATE SERIES
VJA100 . . . . . . . . . . . . .PR8 VERSAMATE SERIES
VJA200 . . . . . . . . . . . . .PR9 VERSAMATE SERIES
VJBC . . . . . . . . . . . . . . .F43 VJ SERIES
VJC37 . . . . . . . . . . . . . .PR8 VERSAMATE SERIES
VJC47 . . . . . . . . . . . . . .PR8 VERSAMATE SERIES
VJC57 . . . . . . . . . . . . . .PR8 VERSAMATE SERIES
VJC67 . . . . . . . . . . . . . .PR8 VERSAMATE SERIES
VJC78 . . . . . . . . . . . . . .PR9 VERSAMATE SERIES
VJH-1 . . . . . . . . . . . . . .F43 VJ SERIES
VJH-2 . . . . . . . . . . . . . .F43 VJ SERIES
VLJDX-2 . . . . . . . . . . . .F43 VJ SERIES
VLJDX-3 . . . . . . . . . . . .F43 VJ SERIES
VLJSX-1 . . . . . . . . . . . .F43 VJ SERIES
VLJSX-2 . . . . . . . . . . . .F43 VJ SERIES
VLJX-1 . . . . . . . . . . . . .F43 VJ SERIES
VLJX-1M . . . . . . . . . . .F43 VJ SERIES
VLJX-2 . . . . . . . . . . . . .F43 VJ SERIES
VLJX-2M . . . . . . . . . . .F43 VJ SERIES
VLJX-3 . . . . . . . . . . . . .F43 VJ SERIES
VLJX-3M . . . . . . . . . . .F43 VJ SERIES
VM & EZ FUES KITS . . . . . . . . . . . . . . . . . . . . .L97-L98
VM1SERIES .............................L58-65
VM1H050 . . . . . . . . . . .L94 VM SERIES
VM1H056 . . . . . . . . . . .L94 VM SERIES
VM1H070 . . . . . . . . . . .L94 VM SERIES
VM1H075 . . . . . . . . . . .L94 VM SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
INTRODUCTION
NUMERIC INDEX
N12
VM1H076 . . . . . . . . . . .L94 VM SERIES
VM1H100 . . . . . . . . . . .L94 VM SERIES
VM1H105 . . . . . . . . . . .L94 VM SERIES
VM1H106 . . . . . . . . . . .L94 VM SERIES
VM1LSERIES ............................L37-40
VM1L4530 . . . . . . . . . .L40 VM1L SERIES
VM1P150 . . . . . . . . . . .L94 VM SERIES
VM1P155 . . . . . . . . . . .L94 VM SERIES
VM1P156 . . . . . . . . . . .L94 VM SERIES
VM1P170 . . . . . . . . . . .L94 VM SERIES
VM1P175 . . . . . . . . . . .L94 VM SERIES
VM1P176 . . . . . . . . . . .L94 VM SERIES
VM1Q051 . . . . . . . .L91-92 VM SERIES
VM1Q0532 . . . . . . .L91-92 VM SERIES
VM1S031 . . . . . . . . . . .L94 VM SERIES
VM1S050 . . . . . . . . . . .L94 VM SERIES
VM1S070 . . . . . . . . . . .L94 VM SERIES
VM1S075 . . . . . . . . . . .L94 VM SERIES
VM1S076 . . . . . . . . . . .L94 VM SERIES
VM1S100 . . . . . . . . . . .L94 VM SERIES
VM1S105 . . . . . . . . . . .L94 VM SERIES
VM1S106 . . . . . . . . . . .L94 VM SERIES
VM1S150 . . . . . . . . . . .L94 VM SERIES
VM1S155 . . . . . . . . . . .L94 VM SERIES
VM1S156 . . . . . . . . . . .L94 VM SERIES
VM2SERIES .............................L58-65
VM2H050 . . . . . . . . . . .L94 VM SERIES
VM2H056 . . . . . . . . . . .L94 VM SERIES
VM2H070 . . . . . . . . . . .L94 VM SERIES
VM2H075 . . . . . . . . . . .L94 VM SERIES
VM2H076 . . . . . . . . . . .L94 VM SERIES
VM2H100 . . . . . . . . . . .L94 VM SERIES
VM2H105 . . . . . . . . . . .L94 VM SERIES
VM2H106 . . . . . . . . . . .L94 VM SERIES
VM2P150 . . . . . . . . . . .L94 VM SERIES
VM2P155 . . . . . . . . . . .L94 VM SERIES
VM2P156 . . . . . . . . . . .L94 VM SERIES
VM2P170 . . . . . . . . . . .L94 VM SERIES
VM2P175 . . . . . . . . . . .L94 VM SERIES
VM2P176 . . . . . . . . . . .L94 VM SERIES
VM2S031 . . . . . . . . . . .L94 VM SERIES
VM2S050 . . . . . . . . . . .L94 VM SERIES
VM2S070 . . . . . . . . . . .L94 VM SERIES
VM2S075 . . . . . . . . . . .L94 VM SERIES
VM2S076 . . . . . . . . . . .L94 VM SERIES
VM2S100 . . . . . . . . . . .L94 VM SERIES
VM2S105 . . . . . . . . . . .L94 VM SERIES
VM2S106 . . . . . . . . . . .L94 VM SERIES
VM2S150 . . . . . . . . . . .L94 VM SERIES
VM2S155 . . . . . . . . . . .L94 VM SERIES
VM2S156 . . . . . . . . . . .L94 VM SERIES
VM3SERIES .............................L66-78
VM3H070 . . . . . . . . . . .L94 VM SERIES
VM3H075 . . . . . . . . . . .L94 VM SERIES
VM3H076 . . . . . . . . . . .L94 VM SERIES
VM3H100 . . . . . . . . . . .L94 VM SERIES
VM3H105 . . . . . . . . . . .L94 VM SERIES
VM3H106 . . . . . . . . . . .L94 VM SERIES
VM3H170 . . . . . . . . . . .L94 VM SERIES
VM3H175 . . . . . . . . . . .L94 VM SERIES
VM3H176 . . . . . . . . . . .L94 VM SERIES
VM3H250 . . . . . . . . . . .L94 VM SERIES
VM3H255 . . . . . . . . . . .L94 VM SERIES
VM3H256 . . . . . . . . . . .L94 VM SERIES
VM3P150 . . . . . . . . . . .L94 VM SERIES
VM3P155 . . . . . . . . . . .L94 VM SERIES
VM3P156 . . . . . . . . . . .L94 VM SERIES
VM3P170 . . . . . . . . . . .L94 VM SERIES
VM3P175 . . . . . . . . . . .L94 VM SERIES
VM3P176 . . . . . . . . . . .L94 VM SERIES
VM3P200 . . . . . . . . . . .L94 VM SERIES
VM3P205 . . . . . . . . . . .L94 VM SERIES
VM3P206 . . . . . . . . . . .L94 VM SERIES
VM3S050 . . . . . . . . . . .L94 VM SERIES
VM3S055 . . . . . . . . . . .L94 VM SERIES
VM3S056 . . . . . . . . . . .L94 VM SERIES
VM3S070 . . . . . . . . . . .L94 VM SERIES
VM3S075 . . . . . . . . . . .L94 VM SERIES
VM3S076 . . . . . . . . . . .L94 VM SERIES
VM3S100 . . . . . . . . . . .L94 VM SERIES
VM3S105 . . . . . . . . . . .L94 VM SERIES
VM3S106 . . . . . . . . . . .L94 VM SERIES
VM3S150 . . . . . . . . . . .L94 VM SERIES
VM3S155 . . . . . . . . . . .L94 VM SERIES
VM3S156 . . . . . . . . . . .L94 VM SERIES
VM4SERIES .............................L66-78
VM4H070 . . . . . . . . . . .L94 VM SERIES
VM4H075 . . . . . . . . . . .L94 VM SERIES
VM4H076 . . . . . . . . . . .L94 VM SERIES
VM4H100 . . . . . . . . . . .L94 VM SERIES
VM4H105 . . . . . . . . . . .L94 VM SERIES
VM4H106 . . . . . . . . . . .L94 VM SERIES
VM4H170 . . . . . . . . . . .L94 VM SERIES
VM4H175 . . . . . . . . . . .L94 VM SERIES
VM4H176 . . . . . . . . . . .L94 VM SERIES
VM4H250 . . . . . . . . . . .L94 VM SERIES
VM4H255 . . . . . . . . . . .L94 VM SERIES
VM4H256 . . . . . . . . . . .L94 VM SERIES
VM4P150 . . . . . . . . . . .L94 VM SERIES
VM4P155 . . . . . . . . . . .L94 VM SERIES
VM4P156 . . . . . . . . . . .L94 VM SERIES
VM4P170 . . . . . . . . . . .L94 VM SERIES
VM4P175 . . . . . . . . . . .L94 VM SERIES
VM4P176 . . . . . . . . . . .L94 VM SERIES
VM4P200 . . . . . . . . . . .L94 VM SERIES
VM4P205 . . . . . . . . . . .L94 VM SERIES
VM4P206 . . . . . . . . . . .L94 VM SERIES
VM4Q081 . . . . . . . .L91-92 VM SERIES
VM4Q0832 . . . . . . .L91-92 VM SERIES
VM4S050 . . . . . . . . . . .L94 VM SERIES
VM4S055 . . . . . . . . . . .L94 VM SERIES
VM4S056 . . . . . . . . . . .L94 VM SERIES
VM4S070 . . . . . . . . . . .L94 VM SERIES
VM4S075 . . . . . . . . . . .L94 VM SERIES
VM4S076 . . . . . . . . . . .L94 VM SERIES
VM4S100 . . . . . . . . . . .L94 VM SERIES
VM4S105 . . . . . . . . . . .L94 VM SERIES
VM4S106 . . . . . . . . . . .L94 VM SERIES
VM4S150 . . . . . . . . . . .L94 VM SERIES
VM4S155 . . . . . . . . . . .L94 VM SERIES
VM4S156 . . . . . . . . . . .L94 VM SERIES
VM5SERIES .............................L79-89
VM5H400 . . . . . . . . . . .L94 VM SERIES
VM5H405 . . . . . . . . . . .L94 VM SERIES
VM5H406 . . . . . . . . . . .L94 VM SERIES
VM5P250 . . . . . . . . . . .L94 VM SERIES
VM5P255 . . . . . . . . . . .L94 VM SERIES
VM5P256 . . . . . . . . . . .L94 VM SERIES
VM5P320 . . . . . . . . . . .L94 VM SERIES
VM5P325 . . . . . . . . . . .L94 VM SERIES
VM5P326 . . . . . . . . . . .L94 VM SERIES
VM5P350 . . . . . . . . . . .L94 VM SERIES
VM5P355 . . . . . . . . . . .L94 VM SERIES
VM5P356 . . . . . . . . . . .L94 VM SERIES
VM5P400 . . . . . . . . . . .L94 VM SERIES
VM5P405 . . . . . . . . . . .L94 VM SERIES
VM5P406 . . . . . . . . . . .L94 VM SERIES
VM5Q161 . . . . . . . .L91-92 VM SERIES
VM5Q1632 . . . . . . .L91-92 VM SERIES
VM5S200 . . . . . . . . . . .L94 VM SERIES
VM5S205 . . . . . . . . . . .L94 VM SERIES
VM5S206 . . . . . . . . . . .L94 VM SERIES
VM5S250 . . . . . . . . . . .L94 VM SERIES
VM5S255 . . . . . . . . . . .L94 VM SERIES
VM5S256 . . . . . . . . . . .L94 VM SERIES
VM5S400 . . . . . . . . . . .L94 VM SERIES
VM5S405 . . . . . . . . . . .L94 VM SERIES
VM5S406 . . . . . . . . . . .L94 VM SERIES
VM5S600 . . . . . . . . . . .L94 VM SERIES
VM5S605 . . . . . . . . . . .L94 VM SERIES
VM5S606 . . . . . . . . . . .L94 VM SERIES
VMA2B . . . . . . . .L40,48,94 VM SERIES
VMA3B . . . . . . . .L40,48,94 VM SERIES
VMAG17 . . . . . . .L40,48,95 VM SERIES
VMAG25S . . . . . . . .L48,95 VM SERIES
VMAG40S . . . . . . .L95,161 VM SERIES
VMAGBC . . . . . . . .L95,161 VM SERIES
VMAGSC . . . . . . . . . . .L96 VM SERIES
VMB2B . . . . . . . .L40,48,94 VM SERIES
VMB3B . . . . . . . .L40,48,94 VM SERIES
VMBNKIT . . . . . . . . . . .L96 VM SERIES
VMC2B . . . . . . . .L40,48,94 VM SERIES
VMC3B . . . . . . . .L40,48,94 VM SERIES
VMCHVM . . . . . . . . . .L223 VM SERIES
VMD4B . . . . . . . .L40,48,94 VM SERIES
VMD5B . . . . . . . .L40,48,94 VM SERIES
VMDARK1 . . . . . . . . . .L96 VM SERIES
VMEP40 . . . . . . . . .L48,95 VM SERIES
VMER40 . . . . . . . . .L48,95 VM SERIES
VMERG . . . . . . . . . .L48,95 VM SERIES
VMEZA . . . . . . . .L40,48,94 VM SERIES
VMFSPC1 ............................L19,40,195
VMFSPC2 ............................L19,40,195
VMFSPC3 ............................L19,40,195
VMG17 . . . . . . . .L40,48,95 VM SERIES
VMG17F . . . . . . . . . . . .L95 VM SERIES
VMG17T . . . . . . .L40,48,95 VM SERIES
VMG25 . . . . . . . . . .L48,95 VM SERIES
VMG25F . . . . . . . . . . . .L95 VM SERIES
VMG25T . . . . . . . . . . . .L95 VM SERIES
VMG40 . . . . . . . . . . . . .L95 VM SERIES
VMG40F . . . . . . . . . . . .L95 VM SERIES
VMG40T . . . . . . . . . . . .L95 VM SERIES
VMHKPC1..........................L134,140,160
VMHKPC2..........................L134,140,160
VMPA-17 . . . . . . . . .L19,27 MB SERIES
VMPA40 . . .L40,48,95,161 VM SERIES
VMPSD-17 . . . . . . .L19,27 MB SERIES
VMPSD40 . .L40,48,95,161 VM SERIES
VMR171 . . . . . . .L40,48,95 VM SERIES
VMR171T . . . . . .L40,48,95 VM SERIES
VMR175 . . . . . . .L40,48,95 VM SERIES
VMR175T . . . . . .L40,48,95 VM SERIES
VMR251 . . . . . . . . .L48,95 VM SERIES
VMR251T . . . . . . . . . . .L95 VM SERIES
VMR253 . . . . . . . . .L48,95 VM SERIES
VMR253T . . . . . . . . . . .L95 VM SERIES
VMR255 . . . . . . . . .L48,95 VM SERIES
VMR255T . . . . . . . . . . .L95 VM SERIES
VMRWG8 . . . . . .L40,48,95 VM SERIES
VMRWG-8 . . . . . . . .L19,27 MB SERIES
VMRWGS . . . . . .L40,48,95 VM SERIES
VMS4B . . . . . . . .L40,48,94 VM SERIES
VMS5B . . . . . . . .L40,48,94 VM SERIES
VMSC10 . . . . . . . . . . . .L96 VM SERIES
VMX2B . . . . . . . .L40,48,94 VM SERIES
VMX3B . . . . . . . .L40,48,94 VM SERIES
VMX6B . . . . . . . .L40,48,94 VM SERIES
VMX7B . . . . . . . .L40,48,94 VM SERIES
VMX8B . . . . . . . .L40,48,94 VM SERIES
VMX9B . . . . . . . .L40,48,94 VM SERIES
VOB-100 . . . . . . . . . . . . .L7 V SERIES
VOB-200 . . . . . . . . . . . . .L7 V SERIES
VOBG-100 . . . . . . . . . . .L7 V SERIES
VOBG-200 . . . . . . . . . . .L7 V SERIES
VOBL-100 . . . . . . . . . . . .L8 V SERIES
VOBL-200 . . . . . . . . . . . .L8 V SERIES
VOBLG-100 . . . . . . . . . .L8 V SERIES
VOBLG-200 . . . . . . . . . .L8 V SERIES
VP10277 . . . . . . . . . . .PR8 VERSAMATE SERIES
VP10377 . . . . . . . . . . .PR8 VERSAMATE SERIES
VP10387 . . . . . . . . . . .PR8 VERSAMATE SERIES
VP10477 . . . . . . . . . . .PR8 VERSAMATE SERIES
VP10487 . . . . . . . . . . .PR8 VERSAMATE SERIES
VP203512 . . . . . . . . . .PR9 VERSAMATE SERIES
VP203612 . . . . . . . . . .PR9 VERSAMATE SERIES
VP204513 . . . . . . . . . .PR9 VERSAMATE SERIES
VP204612 . . . . . . . . . .PR9 VERSAMATE SERIES
VP3275 . . . . . . . . . . . .PR6 VERSAMATE SERIES
VP3375 . . . . . . . . . . . .PR6 VERSAMATE SERIES
VP3385 . . . . . . .PR6,10,11 VERSAMATE SERIES
VP3475 . . . . . . . . . . . .PR6 VERSAMATE SERIES
VP3485 . . . . . . .PR6,10,11 VERSAMATE SERIES
VP6275 . . . . . . . . . . . .PR7 VERSAMATE SERIES
VP6375 . . . . . . . . . . . .PR7 VERSAMATE SERIES
VP6385 . . . . . . .PR7,10,11 VERSAMATE SERIES
VP6475 . . . . . . . . . . . .PR7 VERSAMATE SERIES
VP6485 . . . . . . .PR7,10,11 VERSAMATE SERIES
VPFH-2 . . . . . . . . . . . .L220 FIXTURE HANGERS
VPFHA-12 . . . . . . . . .L220 FIXTURE HANGERS
VPFHA-22 . . . . . . . . .L220 FIXTURE HANGERS
VPFHC-12 . . . . . . . . .L220 FIXTURE HANGERS
VPFHC-22 . . . . . . . . .L220 FIXTURE HANGERS
VPFHH-12 . . . . . . . . .L220 FIXTURE HANGERS
VPFHH-22 . . . . . . . . .L220 FIXTURE HANGERS
VPFHX-12 . . . . . . . . .L220 FIXTURE HANGERS
VPFHX-22 . . . . . . . . .L220 FIXTURE HANGERS
VPLCG-100 . . . . . . . . .L12 V SERIES
VPLCG-200 . . . . . . . . .L12 V SERIES
VPR10257 . . . . . . . . . .PR8 VERSAMATE SERIES
VPR10357 . . . . . . . . . .PR8 VERSAMATE SERIES
VPR10367 . . . . . . . . . .PR8 VERSAMATE SERIES
VPR10457 . . . . . . . . . .PR8 VERSAMATE SERIES
VPR10467 . . . . . . . . . .PR8 VERSAMATE SERIES
VPR203112 . . . . . . . . .PR9 VERSAMATE SERIES
VPR203212 . . . . . . . . .PR9 VERSAMATE SERIES
VPR204113 . . . . . . . . .PR9 VERSAMATE SERIES
VPR204212 . . . . . . . . .PR9 VERSAMATE SERIES
VPR3255 . . . . . . . . . . .PR6 VERSAMATE SERIES
VPR3355 . . . . . . . . . . .PR6 VERSAMATE SERIES
VPR3365 . . . . . . . . . . .PR6 VERSAMATE SERIES
VPR3455 . . . . . . . . . . .PR6 VERSAMATE SERIES
VPR3465 . . . . . . . . . . .PR6 VERSAMATE SERIES
VPR6255 . . . . . . . . . . .PR7 VERSAMATE SERIES
VPR6355 . . . . . . . . . . .PR7 VERSAMATE SERIES
VPR6365 . . . . . . . . . . .PR7 VERSAMATE SERIES
VPR6455 . . . . . . . . . . .PR7 VERSAMATE SERIES
VPR6465 . . . . . . . . . . .PR7 VERSAMATE SERIES
VPRSD-100 . . . . . . . . .L12 V SERIES
VPRSD-200 . . . . . . . . .L12 V SERIES
VQ1FSERIES .............................L45-48
VQ1F1330 . . . . . . . . . . .L48 VQ1F SERIES
VQ1F1830 . . . . . . . . . . .L48 VQ1F SERIES
VQ1F2630 . . . . . . . . . . .L48 VQ1F SERIES
VQ1F26S30 . . . . . . . . .L48 VQ1F SERIES
VQ1F3230 . . . . . . . . . . .L48 VQ1F SERIES
VQ1F3630 . . . . . . . . . . .L48 VQ1F SERIES
VQ1F4230 . . . . . . . . . . .L48 VQ1F SERIES
VQ1F5230 . . . . . . . . . . .L48 VQ1F SERIES
VQ1F6430 . . . . . . . . . . .L48 VQ1F SERIES
VQ1F8430 . . . . . . . . . . .L48 VQ1F SERIES
VQ2FSERIES .............................L45-48
VQ2F1330 . . . . . . . . . . .L48 VQ2F SERIES
VQ2F1830 . . . . . . . . . . .L48 VQ2F SERIES
VQ2F2630 . . . . . . . . . . .L48 VQ2F SERIES
VQ2F26S30 . . . . . . . . .L48 VQ2F SERIES
VQ2F3230 . . . . . . . . . . .L48 VQ2F SERIES
VQ2F3630 . . . . . . . . . . .L48 VQ2F SERIES
VQ2F4230 . . . . . . . . . . .L48 VQ2F SERIES
VQ2F5230 . . . . . . . . . . .L48 VQ2F SERIES
VQ2F6430 . . . . . . . . . . .L48 VQ2F SERIES
VQ2F8430 . . . . . . . . . . .L48 VQ2F SERIES
VR1021 . . . . . . . . . . . .PR8 VERSAMATE SERIES
VR1021C3 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1021C4 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1021C5 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1021C6 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1021E3 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1021E4 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1021E5 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1021E6 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1031 . . . . . . . . . . . .PR8 VERSAMATE SERIES
VR1031C3 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1031C4 . . . . . . . . . .PR8 VERSAMATE SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
INTRODUCTION
NUMERIC INDEX N13
VR1031C5 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1031C6 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1031E3 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1031E4 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1031E5 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1031E6 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1032 . . . . . . . . . . . .PR8 VERSAMATE SERIES
VR1032C3 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1032C4 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1032C5 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1032C6 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1032E3 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1032E4 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1032E5 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1032E6 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1041 . . . . . . . . . . . .PR8 VERSAMATE SERIES
VR1041C3 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1041C4 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1041C5 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1041C6 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1041E3 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1041E4 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1041E5 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1041E6 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1042 . . . . . . . . . . . .PR8 VERSAMATE SERIES
VR1042C3 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1042C4 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1042C5 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1042C6 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1042E3 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1042E4 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1042E5 . . . . . . . . . .PR8 VERSAMATE SERIES
VR1042E6 . . . . . . . . . .PR8 VERSAMATE SERIES
VR20312 . . . . . . . . . . .PR9 VERSAMATE SERIES
VR20312C7 . . . . . . . . .PR9 VERSAMATE SERIES
VR20312E5 . . . . . . . . .PR9 VERSAMATE SERIES
VR20312E6 . . . . . . . . .PR9 VERSAMATE SERIES
VR20312E7 . . . . . . . . .PR9 VERSAMATE SERIES
VR20322 . . . . . . . . . . .PR9 VERSAMATE SERIES
VR20322C7 . . . . . . . . .PR9 VERSAMATE SERIES
VR20322E5 . . . . . . . . .PR9 VERSAMATE SERIES
VR20322E6 . . . . . . . . .PR9 VERSAMATE SERIES
VR20322E7 . . . . . . . . .PR9 VERSAMATE SERIES
VR20412 . . . . . . . . . . .PR9 VERSAMATE SERIES
VR20412C7 . . . . . . . . .PR9 VERSAMATE SERIES
VR20412E5 . . . . . . . . .PR9 VERSAMATE SERIES
VR20412E6 . . . . . . . . .PR9 VERSAMATE SERIES
VR20412E7 . . . . . . . . .PR9 VERSAMATE SERIES
VR20422 . . . . . . . . . . .PR9 VERSAMATE SERIES
VR20422C7 . . . . . . . . .PR9 VERSAMATE SERIES
VR20422E5 . . . . . . . . .PR9 VERSAMATE SERIES
VR20422E6 . . . . . . . . .PR9 VERSAMATE SERIES
VR20422E7 . . . . . . . . .PR9 VERSAMATE SERIES
VR321 . . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VR321C1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR321C2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR321C3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR321D1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR321D2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR321D3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR321E1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR321E2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR321E3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR331 . . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VR331C1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR331C2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR331C3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR331D1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR331D2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR331D3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR331E1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR331E2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR331E3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR332 . . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VR332C1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR332C2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR332C3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR332D1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR332D2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR332D3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR332E1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR332E2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR332E3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR341 . . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VR341C1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR341C2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR341C3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR341D1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR341D2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR341D3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR341E1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR341E2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR341E3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR342 . . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VR342C1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR342C2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR342C3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR342D1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR342D2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR342D3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR342E1 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR342E2 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR342E3 . . . . . . . . . . .PR6 VERSAMATE SERIES
VR621 . . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VR621C3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR621C4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR621C5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR621D3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR621D4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR621D5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR621E3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR621E4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR621E5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR631 . . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VR631C3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR631C4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR631C5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR631D3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR631D4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR631D5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR631E3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR631E4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR631E5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR632 . . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VR632C3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR632C4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR632C5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR632D3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR632D4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR632D5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR632E3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR632E4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR632E5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR641 . . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VR641C3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR641C4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR641C5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR641D3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR641D4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR641D5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR641E3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR641E4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR641E5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR642 . . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VR642C3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR642C4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR642C5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR642D3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR642D4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR642D5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR642E3 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR642E4 . . . . . . . . . . .PR7 VERSAMATE SERIES
VR642E5 . . . . . . . . . . .PR7 VERSAMATE SERIES
VRC13 . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VRC23 . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VRC33 . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VRC36 . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VRC46 . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VRC56 . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VRD13 . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VRD23 . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VRD33 . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VRD36 . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VRD46 . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VRD56 . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VRE13 . . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VRE23 . . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VRE33 . . . . . . . . . . . . . .PR6 VERSAMATE SERIES
VRE36 . . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VRE46 . . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VRE56 . . . . . . . . . . . . . .PR7 VERSAMATE SERIES
VRG-100 . . . . . . . . . . . .L12 V SERIES
VRG-200 . . . . . . . . . . . .L12 V SERIES
VRGP-100 . . . . . . . . . . .L12 V SERIES
VRGP-200 . . . . . . . . . . .L12 V SERIES
VRME . . . . . . . . . . . .L12,14 V SERIES
VRSG-100 . . . . . . . . . . .L12 V SERIES
VSI125801140 . . . . . .PR15 VSI SERIES
VSI125P405 . . . . . . . .PR15 VSI SERIES
VSI125P407 . . . . . . . .PR15 VSI SERIES
VSI125P409 . . . . . . . .PR15 VSI SERIES
VSI125P505 . . . . . . . .PR15 VSI SERIES
VSI125P507 . . . . . . . .PR15 VSI SERIES
VSI125P509 . . . . . . . .PR15 VSI SERIES
VSI125R405 . . . . . . . .PR15 VSI SERIES
VSI125R407 . . . . . . . .PR15 VSI SERIES
VSI125R409 . . . . . . . .PR15 VSI SERIES
VSI125R505 . . . . . . . .PR15 VSI SERIES
VSI125R507 . . . . . . . .PR15 VSI SERIES
VSI125R509 . . . . . . . .PR15 VSI SERIES
VSI20P304 . . . . . .PR14,17 VSI SERIES
VSI20P306 . . . . . .PR14,17 VSI SERIES
VSI20P307 . . . . . .PR14,17 VSI SERIES
VSI20P405 . . . . . .PR14,17 VSI SERIES
VSI20P407 . . . . . .PR14,17 VSI SERIES
VSI20P409 . . . . . .PR14,17 VSI SERIES
VSI20P505 . . . . . .PR14,17 VSI SERIES
VSI20P507 . . . . . .PR14,17 VSI SERIES
VSI20P509 . . . . . .PR14,17 VSI SERIES
VSI20R304 . . . . . . . . .PR14 VSI SERIES
VSI20R306 . . . . . . . . .PR14 VSI SERIES
VSI20R307 . . . . . . . . .PR14 VSI SERIES
VSI20R405 . . . . . . . . .PR14 VSI SERIES
VSI20R407 . . . . . . . . .PR14 VSI SERIES
VSI20R409 . . . . . . . . .PR14 VSI SERIES
VSI20R505 . . . . . . . . .PR14 VSI SERIES
VSI20R507 . . . . . . . . .PR14 VSI SERIES
VSI20R509 . . . . . . . . .PR14 VSI SERIES
VSI30P405 . . . . . .PR14,17 VSI SERIES
VSI30P407 . . . . . .PR14,17 VSI SERIES
VSI30P409 . . . . . .PR14,17 VSI SERIES
VSI30P505 . . . . . .PR14,17 VSI SERIES
VSI30P507 . . . . . .PR14,17 VSI SERIES
VSI30P509 . . . . . .PR14,17 VSI SERIES
VSI30R405 . . . . . . . . .PR14 VSI SERIES
VSI30R407 . . . . . . . . .PR14 VSI SERIES
VSI30R409 . . . . . . . . .PR14 VSI SERIES
VSI30R505 . . . . . . . . .PR14 VSI SERIES
VSI30R507 . . . . . . . . .PR14 VSI SERIES
VSI30R509 . . . . . . . . .PR14 VSI SERIES
VSI63801140 . . . . . . .PR15 VSI SERIES
VSI63P405 . . . . . . . . .PR15 VSI SERIES
VSI63P407 . . . . . . . . .PR15 VSI SERIES
VSI63P409 . . . . . . . . .PR15 VSI SERIES
VSI63P505 . . . . . . . . .PR15 VSI SERIES
VSI63P507 . . . . . . . . .PR15 VSI SERIES
VSI63P509 . . . . . . . . .PR15 VSI SERIES
VSI63R405 . . . . . . . . .PR15 VSI SERIES
VSI63R407 . . . . . . . . .PR15 VSI SERIES
VSI63R409 . . . . . . . . .PR15 VSI SERIES
VSI63R505 . . . . . . . . .PR15 VSI SERIES
VSI63R507 . . . . . . . . .PR15 VSI SERIES
VSI63R509 . . . . . . . . .PR15 VSI SERIES
VSIAUXNC . . . . . . . . .PR14 VSI SERIES
VSIAUXNO . . . . . . . . .PR14 VSI SERIES
VSQ3023 . . . . . . . . . .PR10 VSQ/VWSQ SERIES
VSQ3023FS . . . . . . . .PR11 VSQFS SERIES
VSQ3034 . . . . . . . . . .PR10 VSQ/VWSQ SERIES
VSQ3034FS . . . . . . . .PR11 VSQFS SERIES
VSQ6023 . . . . . . . . . .PR10 VSQ/VWSQ SERIES
VSQ6023FS . . . . . . . .PR11 VSQFS SERIES
VSQ6034 . . . . . . . . . .PR10 VSQ/VWSQ SERIES
VSQ6034FS . . . . . . . .PR11 VSQFS SERIES
VTG................L12 VSERIES
VTGG . . . . . . . . . . . . . .L12 V SERIES
VTGG1-S . . . . . . . . . . .L12 V SERIES
VTGG2-S . . . . . . . . . . .L12 V SERIES
VTG-S . . . . . . . . . . . . . .L12 V SERIES
VUAG-1-100 . . . . . . . . . .L6 V SERIES
VUAG-1-200 . . . . . . . . . .L6 V SERIES
VUAG-2-100 . . . . . . . . . .L6 V SERIES
VUAG-2-200 . . . . . . . . . .L6 V SERIES
VUAGG-1-100 . . . . . . . .L6 V SERIES
VUAGG-1-100PX . . . . .L10 V SERIES
VUAGG-1-200 . . . . . . . .L6 V SERIES
VUAGG-1-200PX . . . . .L10 V SERIES
VUAGG-2-100 . . . . . . . .L6 V SERIES
VUAGG-2-100PX . . . . .L10 V SERIES
VUAGG-2-200 . . . . . . . .L6 V SERIES
VUAGG-2-200PX . . . . .L10 V SERIES
VUCG-1-100 . . . . . . . . .L6 V SERIES
VUCG-1-200 . . . . . . . . .L6 V SERIES
VUCG-2-100 . . . . . . . . .L6 V SERIES
VUCG-2-200 . . . . . . . . .L6 V SERIES
VUCGG-1-100 . . . . . . . .L6 V SERIES
VUCGG-1-200 . . . . . . . .L6 V SERIES
VUCGG-2-100 . . . . . . . .L6 V SERIES
VUCGG-2-200 . . . . . . . .L6 V SERIES
VUHG-1-100 . . . . . . . . .L7 V SERIES
VUHG-1-200 . . . . . . . . .L7 V SERIES
VUHG-2-100 . . . . . . . . .L7 V SERIES
VUHG-2-200 . . . . . . . . .L7 V SERIES
VUHGG-1-100 . . . . . . . .L7 V SERIES
VUHGG-1-200 . . . . . . . .L7 V SERIES
VUHGG-2-100 . . . . . . . .L7 V SERIES
VUHGG-2-200 . . . . . . . .L7 V SERIES
VUXBG-1-100 . . . . . . . .L6 V SERIES
VUXBG-1-200 . . . . . . . .L6 V SERIES
VUXBG-2-100 . . . . . . . .L6 V SERIES
VUXBG-2-200 . . . . . . . .L6 V SERIES
VUXBGG-1-100 . . . . . . .L6 V SERIES
VUXBGG-1-100PX . . . .L10 V SERIES
VUXBGG-1-200 . . . . . . .L6 V SERIES
VUXBGG-1-200PX . . . .L10 V SERIES
VUXBGG-2-100 . . . . . . .L6 V SERIES
VUXBGG-2-100PX . . . .L10 V SERIES
VUXBGG-2-200 . . . . . . .L6 V SERIES
VUXBGG-2-200PX . . . .L10 V SERIES
VUXG-1-100 . . . . . . . . . .L6 V SERIES
VUXG-1-200 . . . . . . . . . .L6 V SERIES
VUXG-2-100 . . . . . . . . . .L6 V SERIES
VUXG-2-200 . . . . . . . . . .L6 V SERIES
VUXGG-1-100 . . . . . . . .L6 V SERIES
VUXGG-1-100PX . . . . .L10 V SERIES
VUXGG-1-200 . . . . . . . .L6 V SERIES
VUXGG-1-200PX . . . . .L10 V SERIES
VUXGG-2-100 . . . . . . . .L6 V SERIES
VUXGG-2-100PX . . . . .L10 V SERIES
VUXGG-2-200 . . . . . . . .L6 V SERIES
VUXGG-2-200PX . . . . .L10 V SERIES
VWSQ3023 . . . . . . . .PR10 VSQ/VWSQ SERIES
VWSQ3034 . . . . . . . .PR10 VSQ/VWSQ SERIES
VWSQ6023 . . . . . . . .PR10 VSQ/VWSQ SERIES
VWSQ6034 . . . . . . . .PR10 VSQ/VWSQ SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
INTRODUCTION
NUMERIC INDEX
N14
VXA-1 . . . . . . . . . . . . . .L11 V SERIES
VXA-2 . . . . . . . . . . . . . .L11 V SERIES
VXAB . . . . . . . . . . . . . . .L11 V SERIES
VXAG-110 . . . . . . . . . . . .L7 V SERIES
VXAG-120 . . . . . . . . . . . .L7 V SERIES
VXAG-210 . . . . . . . . . . . .L7 V SERIES
VXAG-220 . . . . . . . . . . . .L7 V SERIES
VXAGG-110 . . . . . . . . . .L7 V SERIES
VXAGG-120 . . . . . . . . . .L7 V SERIES
VXAGG-210 . . . . . . . . . .L7 V SERIES
VXAGG-220 . . . . . . . . . .L7 V SERIES
VXFC-100 N34 . . . . . . .L11 V SERIES
VXFC-200 N34 . . . . . . .L11 V SERIES
VZRG1550 . . . . .L40,48,95 VM SERIES
VZRG-1550 . . . . . . .L19,27 MB SERIES
VZRG1550T . . . .L40,48,95 VM SERIES
VZRG2520 . . . . . . . .L48,95 VM SERIES
VZRG2520T . . . . . . . . .L95 VM SERIES
VZRG2550 . . . . .L40,48,95 VM SERIES
VZRG2550T . . . .L40,48,95 VM SERIES
VZRG4020 . . . . . . . .L48,95 VM SERIES
VZRG4020T . . . . . . . . .L95 VM SERIES
VZRG4050 . . . . . . . .L48,95 VM SERIES
VZRG4050T . . . . . . . . .L95 VM SERIES
VZRP175 . . . . . . . . .L48,95 VM SERIES
WH-0 . . . . . . . . . . . . . .F28 WH SERIES
WH-1 . . . . . . . . . . . . . .F28 WH SERIES
WH-2 . . . . . . . . . . . . . .F28 WH SERIES
WH-3 . . . . . . . . . . . . . .F28 WH SERIES
WH-4 . . . . . . . . . . . . . .F28 WH SERIES
WH-5 . . . . . . . . . . . . . .F28 WH SERIES
WH-6 . . . . . . . . . . . . . .F28 WH SERIES
WH-7 . . . . . . . . . . . . . .F28 WH SERIES
WH-8 . . . . . . . . . . . . . .F28 WH SERIES
WH-9 . . . . . . . . . . . . . .F28 WH SERIES
X-10 . . . . . . . . . . . .C26,37 XCS SERIES
X-11 . . . . . . . . . . . . . . .C37 GCS/SWBC SERIES
X-12 . . . . . . . . . . . . . . .C37 GCS/SWBC SERIES
X17 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
X17SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
X18 . . . . . . . . . . . . . . . .F13 DURALOY 8 SERIES
X27 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
X27SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
X28 . . . . . . . . . . . . . . . .F13 DURALOY 8 SERIES
X37 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
X37SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
X38 . . . . . . . . . . . . . . . .F13 DURALOY 8 SERIES
X448 . . . . . . . . . . . . . . .F13 DURALOY 8 SERIES
X47 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
X47SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
X57 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
X57SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
X58 . . . . . . . . . . . . . . . .F13 DURALOY 8 SERIES
X-60 . . . . . . . . . . . .C26,37 XCS SERIES
X-61 . . . . . . . . . . . . . . .C37 GCS/SWBC SERIES
X-62 . . . . . . . . . . . . . . .C37 GCS/SWBC SERIES
X-64 . . . . . . . . . . . . . . .C26 XCS SERIES
X67 . . . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
X67SA . . . . . . . . . . . . . . .F6 DURALOY 7 SERIES
X68 . . . . . . . . . . . . . . . .F13 DURALOY 8 SERIES
X-83 . . . . . . . . . . . . . . .C37 GCS/SWBC SERIES
X-84 . . . . . . . . . . . . . . .C37 GCS/SWBC SERIES
X-85 . . . . . . . . . . . . . . .C37 GCS/SWBC SERIES
XAL-458 . . . . . . . . . . . .C29 XAL/XAS SERIES
XAL-53 . . . . . . . . . . . . .C29 XAL/XAS SERIES
XALB-4 . . . . . . . . . . . . .F59 XALB SERIES
XALB-5 . . . . . . . . . . . . .F59 XALB SERIES
XALB-6 . . . . . . . . . . . . .F59 XALB SERIES
XALB-7 . . . . . . . . . . . . .F59 XALB SERIES
XALB-8 . . . . . . . . . . . . .F59 XALB SERIES
XAS-53 . . . . . . . . . . . . .C29 XAL/XAS SERIES
XC-1 . . . . . . . . . . . . . . .F59 X SERIES
XC-2 . . . . . . . . . . . . . . .F59 X SERIES
XC-3 . . . . . . . . . . . . . . .F59 X SERIES
XCS-0A15 . . . . . . . . . .C22 XCS SERIES
XCS-0A8 . . . . . . . . . . .C21 XCS SERIES
XCS-0A9 . . . . . . . . . . .C21 XCS SERIES
XCS-0B1 . . . . . . . . . . .C21 XCS SERIES
XCS-0B13-C . . . . . . . .C22 XCS SERIES
XCS-0B13-O . . . . . . . .C22 XCS SERIES
XCS-0B13-U . . . . . . . .C22 XCS SERIES
XCS-0B2 . . . . . . . . . . .C21 XCS SERIES
XCS-0B24-CL . . . . . . .C22 XCS SERIES
XCS-0B24-GL . . . . . . .C22 XCS SERIES
XCS-0B24-RL . . . . . . .C22 XCS SERIES
XCS-0B3 . . . . . . . . . . .C21 XCS SERIES
XCS-0B30-CL . . . . . . .C22 XCS SERIES
XCS-0B30-GL . . . . . . .C22 XCS SERIES
XCS-0B30-RL . . . . . . .C22 XCS SERIES
XCS-0B30RL-GL . . . . .C22 XCS SERIES
XCS-0B3-PTT . . . . . .L212 XCS SERIES
XCS-0B4 . . . . . . . . . . .C21 XCS SERIES
XCS-0B4-U . . . . . . . . .C21 XCS SERIES
XCS-0B5 . . . . . . . . . . .C21 XCS SERIES
XCS-0B7 . . . . . . . . . . .C21 XCS SERIES
XCS-0K2A1D . . . . . . . .C23 XCS SERIES
XCS-0K2A5D . . . . . . . .C23 XCS SERIES
XCS-0K2L3F22D . . . . .C25 XCS SERIES
XCS-0K3C4D . . . . . . . .C23 XCS SERIES
XCS-0K3C5D . . . . . . . .C23 XCS SERIES
XCS-0K3L6G32D . . . .C25 XCS SERIES
XCS-0K3M6G32D . . . .C25 XCS SERIES
XCS-0K3R6G32D . . . .C25 XCS SERIES
XCS-0MMG3 . . . . . . . .C21 XCS SERIES
XCS-0MMK3 . . . . . . . .C21 XCS SERIES
XCS-0MMR3 . . . . . . . .C21 XCS SERIES
XCS-0S2A1 . . . . . . . . .C23 XCS SERIES
XCS-0S2A5 . . . . . . . . .C23 XCS SERIES
XCS-0S2L3F . . . . . . . .C24 XCS SERIES
XCS-0S3C4 . . . . . . . . .C23 XCS SERIES
XCS-0S3C5 . . . . . . . . .C23 XCS SERIES
XCS-0S3L6G . . . . . . . .C24 XCS SERIES
XCS-0S3M6G . . . . . . .C24 XCS SERIES
XCS-0S3R6G . . . . . . . .C24 XCS SERIES
XCS-1A15 . . . . . . . . . .C22 XCS SERIES
XCS-1A8 . . . . . . . . . . .C21 XCS SERIES
XCS-1A9 . . . . . . . . . . .C21 XCS SERIES
XCS-1B1 . . . . . . . . . . .C21 XCS SERIES
XCS-1B13-C . . . . . . . .C22 XCS SERIES
XCS-1B13-O . . . . . . . .C22 XCS SERIES
XCS-1B13-U . . . . . . . .C22 XCS SERIES
XCS-1B2 . . . . . . . . . . .C21 XCS SERIES
XCS-1B24-CL . . . . . . .C22 XCS SERIES
XCS-1B24-GL . . . . . . .C22 XCS SERIES
XCS-1B24-RL . . . . . . .C22 XCS SERIES
XCS-1B3 . . . . . . . . . . .C21 XCS SERIES
XCS-1B30-CL . . . . . . .C22 XCS SERIES
XCS-1B30-GL . . . . . . .C22 XCS SERIES
XCS-1B30-RL . . . . . . .C22 XCS SERIES
XCS-1B30RL-GL . . . . .C22 XCS SERIES
XCS-1B4 . . . . . . . . . . .C21 XCS SERIES
XCS-1B4-U . . . . . . . . .C21 XCS SERIES
XCS-1B5 . . . . . . . . . . .C21 XCS SERIES
XCS-1B7 . . . . . . . . . . .C21 XCS SERIES
XCS-1K2A1D . . . . . . . .C23 XCS SERIES
XCS-1K3C4D . . . . . . . .C23 XCS SERIES
XCS-1S2A1 . . . . . . . . .C23 XCS SERIES
XCS-1S3C4 . . . . . . . . .C23 XCS SERIES
XCS-2A15 . . . . . . . . . .C22 XCS SERIES
XCS-2A8 . . . . . . . . . . .C21 XCS SERIES
XCS-2A9 . . . . . . . . . . .C21 XCS SERIES
XCS-2B1 . . . . . . . . . . .C21 XCS SERIES
XCS-2B13-C . . . . . . . .C22 XCS SERIES
XCS-2B13-O . . . . . . . .C22 XCS SERIES
XCS-2B13-U . . . . . . . .C22 XCS SERIES
XCS-2B2 . . . . . . . . . . .C21 XCS SERIES
XCS-2B24-CL . . . . . . .C22 XCS SERIES
XCS-2B24-GL . . . . . . .C22 XCS SERIES
XCS-2B24-RL . . . . . . .C22 XCS SERIES
XCS-2B3 . . . . . . . . . . .C21 XCS SERIES
XCS-2B30-CL . . . . . . .C22 XCS SERIES
XCS-2B30-GL . . . . . . .C22 XCS SERIES
XCS-2B30-RL . . . . . . .C22 XCS SERIES
XCS-2B30RL-GL . . . . .C22 XCS SERIES
XCS-2B4 . . . . . . . . . . .C21 XCS SERIES
XCS-2B4-U . . . . . . . . .C21 XCS SERIES
XCS-2B5 . . . . . . . . . . .C21 XCS SERIES
XCS-2B7 . . . . . . . . . . .C21 XCS SERIES
XCS-2K2A1D . . . . . . . .C23 XCS SERIES
XCS-2K3C4D . . . . . . . .C23 XCS SERIES
XCS-2S2A1 . . . . . . . . .C23 XCS SERIES
XCS-2S3C4 . . . . . . . . .C23 XCS SERIES
XCS-42K2A5D . . . . . . .C23 XCS SERIES
XCS-42K2L3F22D . . . .C25 XCS SERIES
XCS-42K3C5D . . . . . . .C23 XCS SERIES
XCS-42K3L6G32D . . .C25 XCS SERIES
XCS-42K3M6G32D . . .C25 XCS SERIES
XCS-42K3R6G32D . . .C25 XCS SERIES
XCS-42S2A5 . . . . . . . .C23 XCS SERIES
XCS-42S2L3F . . . . . . .C24 XCS SERIES
XCS-42S3C5 . . . . . . . .C23 XCS SERIES
XCS-42S3L6G . . . . . . .C24 XCS SERIES
XCS-42S3M6G . . . . . .C24 XCS SERIES
XCS-42S3R6G . . . . . . .C24 XCS SERIES
XCS-45K2A5D . . . . . . .C23 XCS SERIES
XCS-45K2L3F22D . . . .C25 XCS SERIES
XCS-45K3C5D . . . . . . .C23 XCS SERIES
XCS-45K3L6G32D . . .C25 XCS SERIES
XCS-45K3M6G32D . . .C25 XCS SERIES
XCS-45K3R6G32D . . .C25 XCS SERIES
XCS-45S2A5 . . . . . . . .C23 XCS SERIES
XCS-45S2L3F . . . . . . .C24 XCS SERIES
XCS-45S3C5 . . . . . . . .C23 XCS SERIES
XCS-45S3L6G . . . . . . .C24 XCS SERIES
XCS-45S3M6G . . . . . .C24 XCS SERIES
XCS-45S3R6G . . . . . . .C24 XCS SERIES
XCS-4A15 . . . . . . . . . .C22 XCS SERIES
XCS-4A8 . . . . . . . . . . .C21 XCS SERIES
XCS-4A9 . . . . . . . . . . .C21 XCS SERIES
XCS-4B1 . . . . . . . . . . .C21 XCS SERIES
XCS-4B13-C . . . . . . . .C22 XCS SERIES
XCS-4B13-O . . . . . . . .C22 XCS SERIES
XCS-4B13-U . . . . . . . .C22 XCS SERIES
XCS-4B2 . . . . . . . . . . .C21 XCS SERIES
XCS-4B24-CL . . . . . . .C22 XCS SERIES
XCS-4B24-GL . . . . . . .C22 XCS SERIES
XCS-4B24-RL . . . . . . .C22 XCS SERIES
XCS-4B3 . . . . . . . . . . .C21 XCS SERIES
XCS-4B30-CL . . . . . . .C22 XCS SERIES
XCS-4B30-GL . . . . . . .C22 XCS SERIES
XCS-4B30-RL . . . . . . .C22 XCS SERIES
XCS-4B30RL-GL . . . . .C22 XCS SERIES
XCS-4B4 . . . . . . . . . . .C21 XCS SERIES
XCS-4B4-U . . . . . . . . .C21 XCS SERIES
XCS-4B5 . . . . . . . . . . .C21 XCS SERIES
XCS-4B7 . . . . . . . . . . .C21 XCS SERIES
XCS-4K2A1D . . . . . . . .C23 XCS SERIES
XCS-4K3C4D . . . . . . . .C23 XCS SERIES
XCS-4S2A1 . . . . . . . . .C23 XCS SERIES
XCS-4S3C4 . . . . . . . . .C23 XCS SERIES
XCS-5A15 . . . . . . . . . .C22 XCS SERIES
XCS-5A8 . . . . . . . . . . .C21 XCS SERIES
XCS-5A9 . . . . . . . . . . .C21 XCS SERIES
XCS-5B1 . . . . . . . . . . .C21 XCS SERIES
XCS-5B13-C . . . . . . . .C22 XCS SERIES
XCS-5B13-O . . . . . . . .C22 XCS SERIES
XCS-5B13-U . . . . . . . .C22 XCS SERIES
XCS-5B2 . . . . . . . . . . .C21 XCS SERIES
XCS-5B24-CL . . . . . . .C22 XCS SERIES
XCS-5B24-GL . . . . . . .C22 XCS SERIES
XCS-5B24-RL . . . . . . .C22 XCS SERIES
XCS-5B3 . . . . . . . . . . .C21 XCS SERIES
XCS-5B30-CL . . . . . . .C22 XCS SERIES
XCS-5B30-GL . . . . . . .C22 XCS SERIES
XCS-5B30-RL . . . . . . .C22 XCS SERIES
XCS-5B30RL-GL . . . . .C22 XCS SERIES
XCS-5B4 . . . . . . . . . . .C21 XCS SERIES
XCS-5B4-U . . . . . . . . .C21 XCS SERIES
XCS-5B5 . . . . . . . . . . .C21 XCS SERIES
XCS-5B7 . . . . . . . . . . .C21 XCS SERIES
XCS-5K2A1D . . . . . . . .C23 XCS SERIES
XCS-5K3C4D . . . . . . . .C23 XCS SERIES
XCS-5S2A1 . . . . . . . . .C23 XCS SERIES
XCS-5S3C4 . . . . . . . . .C23 XCS SERIES
XCSLED-A110 . . . . . . .C27 X/XCS SERIES
XCSLED-G110 . . . . . . .C27 X/XCS SERIES
XCSLED-R110 . . . . . . .C27 X/XCS SERIES
XCSNPPB . . . . . . . . . .C26 XCS SERIES
XCSNPPBM . . . . . . . . .C26 XCS SERIES
XCSNPPL . . . . . . . . . . .C26 XCS SERIES
XCSNPSS2 . . . . . . . . .C26 XCS SERIES
XCSNPSS3 . . . . . . . . .C26 XCS SERIES
XCS-OMMR3 . . . . . . . .C26 XCS SERIES
XDBB . . . . . . . . . . . . . .C26 XCS SERIES
XDBG . . . . . . . . . . . . . .C26 XCS SERIES
XDBR . . . . . . . . . . . . . .C26 XCS SERIES
XDS000C . . . . . . . . . . .DE8 XEDS/XDS SERIES
XDS-2003AA . . . . . . . .DE8 XEDS/XDS SERIES
XECD-154A1 . . . . . . . .DE2 XEC SERIES
XECD-154A2 . . . . . . . .DE2 XEC SERIES
XECD-204A1 . . . . . . . .DE2 XEC SERIES
XECD-204A2 . . . . . . . .DE2 XEC SERIES
XECD-304A1 . . . . . . . .DE2 XEC SERIES
XECD-304A2 . . . . . . . .DE2 XEC SERIES
XECD-404A1 . . . . . . . .DE2 XEC SERIES
XECD-404A2 . . . . . . . .DE2 XEC SERIES
XECD-4A . . . . . . . . . . .DE2 XEC SERIES
XECE-154A3 . . . . . . . .DE2 XEC SERIES
XECE-156A2 . . . . . . . .DE2 XEC SERIES
XECE-156A3 . . . . . . . .DE2 XEC SERIES
XECE-204A3 . . . . . . . .DE2 XEC SERIES
XECE-206A2 . . . . . . . .DE2 XEC SERIES
XECE-206A3 . . . . . . . .DE2 XEC SERIES
XECE-304A3 . . . . . . . .DE2 XEC SERIES
XECE-306A2 . . . . . . . .DE2 XEC SERIES
XECE-306A3 . . . . . . . .DE2 XEC SERIES
XECE-404A3 . . . . . . . .DE2 XEC SERIES
XECE-406A2 . . . . . . . .DE2 XEC SERIES
XECE-406A3 . . . . . . . .DE2 XEC SERIES
XECE-6A . . . . . . . . . . .DE2 XEC SERIES
XECF-1004A1 . . . . . . .DE2 XEC SERIES
XECF-1004A2 . . . . . . .DE2 XEC SERIES
XECF-1004A3 . . . . . . .DE2 XEC SERIES
XECF-1006A2 . . . . . . .DE2 XEC SERIES
XECF-1006A3 . . . . . . .DE2 XEC SERIES
XECF-504A1 . . . . . . . .DE2 XEC SERIES
XECF-504A2 . . . . . . . .DE2 XEC SERIES
XECF-504A3 . . . . . . . .DE2 XEC SERIES
XECF-506A2 . . . . . . . .DE2 XEC SERIES
XECF-506A3 . . . . . . . .DE2 XEC SERIES
XECF-604A1 . . . . . . . .DE2 XEC SERIES
XECF-604A2 . . . . . . . .DE2 XEC SERIES
XECF-604A3 . . . . . . . .DE2 XEC SERIES
XECF-606A2 . . . . . . . .DE2 XEC SERIES
XECF-606A3 . . . . . . . .DE2 XEC SERIES
XECF-6A . . . . . . . . . . .DE2 XEC SERIES
XECF-704A1 . . . . . . . .DE2 XEC SERIES
XECF-704A2 . . . . . . . .DE2 XEC SERIES
XECF-704A3 . . . . . . . .DE2 XEC SERIES
XECF-706A2 . . . . . . . .DE2 XEC SERIES
XECF-706A3 . . . . . . . .DE2 XEC SERIES
XECF-804A1 . . . . . . . .DE2 XEC SERIES
XECF-804A2 . . . . . . . .DE2 XEC SERIES
XECF-804A3 . . . . . . . .DE2 XEC SERIES
XECF-806A2 . . . . . . . .DE2 XEC SERIES
XECF-806A3 . . . . . . . .DE2 XEC SERIES
XECF-904A1 . . . . . . . .DE2 XEC SERIES
XECF-904A2 . . . . . . . .DE2 XEC SERIES
XECF-904A3 . . . . . . . .DE2 XEC SERIES
XECF-906A2 . . . . . . . .DE2 XEC SERIES
XECF-906A3 . . . . . . . .DE2 XEC SERIES
XEDS-100 . . . . . . . . . .DE8 XEDS/XDS SERIES
XEDS-100A . . . . . . . . .DE8 XEDS/XDS SERIES
XEDS-100AA . . . . . . . .DE8 XEDS/XDS SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
INTRODUCTION
NUMERIC INDEX N15
XEDS-30 . . . . . . . . . . .DE8 XEDS/XDS SERIES
XEDS-30A . . . . . . . . . .DE8 XEDS/XDS SERIES
XEDS-30AA . . . . . . . . .DE8 XEDS/XDS SERIES
XEDS-60 . . . . . . . . . . .DE8 XEDS/XDS SERIES
XEDS-60A . . . . . . . . . .DE8 XEDS/XDS SERIES
XEDS-60AA . . . . . . . . .DE8 XEDS/XDS SERIES
XEDS-A . . . . . . . . . . . .DE8 XEDS/XDS SERIES
XEDS-B . . . . . . . . . . . .DE8 XEDS/XDS SERIES
XFH-21 . . . . . . . . . . . .L221 XFH SERIES
XFH-22 . . . . . . . . . . . .L221 XFH SERIES
XHL-100 . . . . . . .L14,PR26 XHL SERIES
XHLF26 . . . . . . . .L14,PR26 XHLF SERIES
XHLF26-50KP . .L14,PR26 XHLF SERIES
XHLG . . . . . . . . .L14,PR26 XHL SERIES
XHL-GL . . . . . . . .L14,PR26 XHL SERIES
XHLS . . . . . . . . . .L14,PR26 XHL SERIES
XJB-164812 . . . . . . . . .E16 XJB SERIES
XJB-20328 . . . . . . . . . .E16 XJB SERIES
XJB-204010 . . . . . . . . .E16 XJB SERIES
XJB-242416 . . . . . . . . .E16 XJB SERIES
XJB-5106 . . . . . . . . . . .E16 XJB SERIES
XJB-5136 . . . . . . . . . . .E16 XJB SERIES
XJB-8136 . . . . . . . . . . .E16 XJB SERIES
XJB-8156 . . . . . . . . . . .E16 XJB SERIES
XJB-8158 . . . . . . . . . . .E16 XJB SERIES
XJB-8186 . . . . . . . . . . .E16 XJB SERIES
XJB-8188 . . . . . . . . . . .E16 XJB SERIES
XLB-1 . . . . . . . . . . . . . .F59 X SERIES
XLB-2 . . . . . . . . . . . . . .F59 X SERIES
XLB-3 . . . . . . . . . . . . . .F59 X SERIES
XLL-1 . . . . . . . . . . . . . .F59 X SERIES
XLL-2 . . . . . . . . . . . . . .F59 X SERIES
XLL-3 . . . . . . . . . . . . . .F59 X SERIES
XLOA . . . . . . . . . . . . . .C26 XCS SERIES
XLOB . . . . . . . . . . . . . .C26 XCS SERIES
XLR-1 . . . . . . . . . . . . . .F59 X SERIES
XLR-2 . . . . . . . . . . . . . .F59 X SERIES
XLR-3 . . . . . . . . . . . . . .F59 X SERIES
XLRT-21 . . . . . . . . . . . .F59 X SERIES
XLRT-22 . . . . . . . . . . . .F59 X SERIES
XMSW-00T . . . . . . . . .C59 XMSW SERIES
XMSW-0BT . . . . . . . . .C59 XMSW SERIES
XMSW-0CT . . . . . . . . .C59 XMSW SERIES
XMSW-1BT . . . . . . . . .C59 XMSW SERIES
XMSW-1CT . . . . . . . . .C59 XMSW SERIES
XMSW-DBT . . . . . . . . .C59 XMSW SERIES
XNS-1C . . . . . . . . . . . .C28 XS SERIES
XNS-1D . . . . . . . . . . . .C28 XS SERIES
XNS-2C . . . . . . . . . . . .C28 XS SERIES
XNS-2D . . . . . . . . . . . .C28 XS SERIES
XNS-3C . . . . . . . . . . . .C28 XS SERIES
XNS-5C . . . . . . . . . . . .C28 XS SERIES
XNS-6C . . . . . . . . . . . .C28 XS SERIES
XNS-7C . . . . . . . . . . . .C28 XS SERIES
XNS-8C . . . . . . . . . . . .C28 XS SERIES
XO1AG . . . . . . . . . . . . .C26 XCS SERIES
XO1AK . . . . . . . . . . . . .C26 XCS SERIES
XO1AR . . . . . . . . . . . . .C26 XCS SERIES
XO1BG . . . . . . . . . . . . .C26 XCS SERIES
XO1BK . . . . . . . . . . . . .C26 XCS SERIES
XO1BR . . . . . . . . . . . . .C26 XCS SERIES
XO21BA . . . . . . . . . . . .C26 XCS SERIES
XO21BC . . . . . . . . . . . .C26 XCS SERIES
XO21BG . . . . . . . . . . . .C26 XCS SERIES
XO21BR . . . . . . . . . . . .C26 XCS SERIES
XO3AG . . . . . . . . . . . . .C26 XCS SERIES
XO3AK . . . . . . . . . . . . .C26 XCS SERIES
XO3AR . . . . . . . . . . . . .C26 XCS SERIES
XO3BG . . . . . . . . . . . . .C26 XCS SERIES
XO3BK . . . . . . . . . . . . .C26 XCS SERIES
XO3BR . . . . . . . . . . . . .C26 XCS SERIES
XO5BR . . . . . . . . . . . . .C26 XCS SERIES
XOAP . . . . . . . . . . . . . .C26 XCS SERIES
XOBP . . . . . . . . . . . . . .C26 XCS SERIES
XS-11C . . . . . . . . . . . .C28 XS SERIES
XS-11D . . . . . . . . . . . .C28 XS SERIES
XS-12C . . . . . . . . . . . .C28 XS SERIES
XS-12D . . . . . . . . . . . .C28 XS SERIES
XS-13C . . . . . . . . . . . .C28 XS SERIES
XS-15C . . . . . . . . . . . .C28 XS SERIES
XS-16C . . . . . . . . . . . .C28 XS SERIES
XS-17C . . . . . . . . . . . .C28 XS SERIES
XS-18C . . . . . . . . . . . .C28 XS SERIES
XS-1C . . . . . . . . . . . . . .C28 XS SERIES
XS-1D . . . . . . . . . . . . . .C28 XS SERIES
XS-21C . . . . . . . . . . . .C28 XS SERIES
XS-21D . . . . . . . . . . . .C28 XS SERIES
XS-22C . . . . . . . . . . . .C28 XS SERIES
XS-22D . . . . . . . . . . . .C28 XS SERIES
XS-23C . . . . . . . . . . . .C28 XS SERIES
XS-25C . . . . . . . . . . . .C28 XS SERIES
XS-26C . . . . . . . . . . . .C28 XS SERIES
XS-27C . . . . . . . . . . . .C28 XS SERIES
XS-28C . . . . . . . . . . . .C28 XS SERIES
XS-2C . . . . . . . . . . . . . .C28 XS SERIES
XS-2D . . . . . . . . . . . . . .C28 XS SERIES
XS-3C . . . . . . . . . . . . . .C28 XS SERIES
XS-41C . . . . . . . . . . . .C28 XS SERIES
XS-41D . . . . . . . . . . . .C28 XS SERIES
XS-42C . . . . . . . . . . . .C28 XS SERIES
XS-42D . . . . . . . . . . . .C28 XS SERIES
XS-43C . . . . . . . . . . . .C28 XS SERIES
XS-45C . . . . . . . . . . . .C28 XS SERIES
XS-46C . . . . . . . . . . . .C28 XS SERIES
XS-47C . . . . . . . . . . . .C28 XS SERIES
XS-48C . . . . . . . . . . . .C28 XS SERIES
XS-4C . . . . . . . . . . . . . .C28 XS SERIES
XS-51C . . . . . . . . . . . .C28 XS SERIES
XS-51D . . . . . . . . . . . .C28 XS SERIES
XS-52C . . . . . . . . . . . .C28 XS SERIES
XS-52D . . . . . . . . . . . .C28 XS SERIES
XS-53C . . . . . . . . . . . .C28 XS SERIES
XS-55C . . . . . . . . . . . .C28 XS SERIES
XS-56C . . . . . . . . . . . .C28 XS SERIES
XS-57C . . . . . . . . . . . .C28 XS SERIES
XS-58C . . . . . . . . . . . .C28 XS SERIES
XS-5C . . . . . . . . . . . . . .C28 XS SERIES
XS-6C . . . . . . . . . . . . . .C28 XS SERIES
XS-7C . . . . . . . . . . . . . .C28 XS SERIES
XS-8C . . . . . . . . . . . . . .C28 XS SERIES
XSD-01 . . . . . . . . . . . .C53 XS SERIES
XSD-02 . . . . . . . . . . . .C53 XS SERIES
XSD-11 . . . . . . . . . . . .C53 XS SERIES
XSD-12 . . . . . . . . . . . .C53 XS SERIES
XSD-21 . . . . . . . . . . . .C53 XS SERIES
XSD-22 . . . . . . . . . . . .C53 XS SERIES
XSD-41 . . . . . . . . . . . .C53 XS SERIES
XSD-42 . . . . . . . . . . . .C53 XS SERIES
XSD-51 . . . . . . . . . . . .C53 XS SERIES
XSD-52 . . . . . . . . . . . .C53 XS SERIES
XSX-12 . . . . . . . . . . . . .C53 XS SERIES
XSX-13 . . . . . . . . . . . . .C53 XS SERIES
XSX-2 . . . . . . . . . . . . . .C53 XS SERIES
XSX-22 . . . . . . . . . . . . .C53 XS SERIES
XSX-23 . . . . . . . . . . . . .C53 XS SERIES
XSX-3 . . . . . . . . . . . . . .C53 XS SERIES
XSX-42 . . . . . . . . . . . . .C53 XS SERIES
XSX-43 . . . . . . . . . . . . .C53 XS SERIES
XSX-52 . . . . . . . . . . . . .C53 XS SERIES
XSX-53 . . . . . . . . . . . . .C53 XS SERIES
XT-1 . . . . . . . . . . . . . . .F59 X SERIES
XT-2 . . . . . . . . . . . . . . .F59 X SERIES
XT-3 . . . . . . . . . . . . . . .F59 X SERIES
Y-1 ................F66 YSERIES
Y-1M . . . . . . . . . . . . . . .F66 Y SERIES
Y-2 ................F66 YSERIES
Y-2M . . . . . . . . . . . . . . .F66 Y SERIES
Y-3 ................F66 YSERIES
Y-3M . . . . . . . . . . . . . . .F66 Y SERIES
Y-4 ................F66 YSERIES
Y-4M . . . . . . . . . . . . . . .F66 Y SERIES
Y-5 ................F66 YSERIES
Y-5M . . . . . . . . . . . . . . .F66 Y SERIES
Y7000ZH . . . . . . . . . . .C50 Y7 SERIES
Y7000ZS . . . . . . . . . . .C50 Y7 SERIES
Y7001ZH . . . . . . . . . . .C50 Y7 SERIES
Y7001ZS . . . . . . . . . . .C50 Y7 SERIES
Y7002ZH . . . . . . . . . . .C50 Y7 SERIES
Y7002ZS . . . . . . . . . . .C50 Y7 SERIES
Y7010ZH . . . . . . . . . . .C50 Y7 SERIES
Y7010ZS . . . . . . . . . . .C50 Y7 SERIES
Y7011ZH . . . . . . . . . . .C50 Y7 SERIES
Y7011ZS . . . . . . . . . . .C50 Y7 SERIES
Y7012ZH . . . . . . . . . . .C50 Y7 SERIES
Y7012ZS . . . . . . . . . . .C50 Y7 SERIES
YOKK-10285 . . . . . . . .C38 GO SERIES
YOKK-10286 . . . . . . . .C38 GO SERIES
YOKK-10287 . . . . . . . .C38 GO SERIES
YOKK-10291 . . . . . . . .C38 GO SERIES
YOKK15214 . . . . . . . . .C29 XAL/XAS SERIES
YOKK-9484-2 . . . . . . .C38 GO SERIES
YOSD-A.49 . . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A.71 . . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A.78 . . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A.86 . . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A.95 . . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A1.02 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A1.16 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A1.25 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A1.39 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A1.54 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A1.63 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A1.75 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A1.86 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A1.99 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A11.0 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A11.9 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A13.2 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A14.1 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A14.8 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A16.2 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A17.9 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A19.8 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A2.31 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A2.57 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A2.81 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A21.3 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A25.2 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A3.61 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A3.95 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A4.32 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A4.79 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A5.30 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A5.78 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A6.20 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A6.99 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A7.65 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A8.38 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A9.25 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSD-A9.85 . . . . . . . .C54 XSD/XSX/FXSD/FXSX SER
YOSY120MB . . . . . .C27,39 X/XCS SERIES
YOSY24MB . . . . . . .C27,39 X/XCS SERIES
YOWEA200-FH03 . . . .C59 XMSW SERIES
YOWEA200-FH04 . . . .C59 XMSW SERIES
YOWEA200-FH05 . . . .C59 XMSW SERIES
YOWEA200-FH06 . . . .C59 XMSW SERIES
YOWEA200-FH07 . . . .C59 XMSW SERIES
YOWEA200-FH08 . . . .C59 XMSW SERIES
YOWEA200-FH09 . . . .C59 XMSW SERIES
YOWEA200-FH10 . . . .C59 XMSW SERIES
YOWEA200-FH11 . . . .C59 XMSW SERIES
YOWEA200-FH12 . . . .C59 XMSW SERIES
YOWEA200-FH13 . . . .C59 XMSW SERIES
YOWEA200-FH14 . . . .C59 XMSW SERIES
YOWEA200-FH15 . . . .C59 XMSW SERIES
YOWEA200-FH16 . . . .C59 XMSW SERIES
YOWEA200-FH17 . . . .C59 XMSW SERIES
YOWEA200-FH18 . . . .C59 XMSW SERIES
YOWEA200-FH19 . . . .C59 XMSW SERIES
YOWEA200-FH20 . . . .C59 XMSW SERIES
YOWEA200-FH21 . . . .C59 XMSW SERIES
YOWEA200-FH22 . . . .C59 XMSW SERIES
YOWEA200-FH23 . . . .C59 XMSW SERIES
YOWEA200-FH24 . . . .C59 XMSW SERIES
YOWEA200-FH25 . . . .C59 XMSW SERIES
YOWEA200-FH26 . . . .C59 XMSW SERIES
YOWEA200-FH27 . . . .C59 XMSW SERIES
YOWEA200-FH28 . . . .C59 XMSW SERIES
YOWEA200-FH29 . . . .C59 XMSW SERIES
YOWEA200-FH30 . . . .C59 XMSW SERIES
YOWEA200-FH31 . . . .C59 XMSW SERIES
YOWEA200-FH32 . . . .C59 XMSW SERIES
YOWEA200-FH33 . . . .C59 XMSW SERIES
YOWEA200-FH34 . . . .C59 XMSW SERIES
YOWEA200-FH35 . . . .C59 XMSW SERIES
YOWEA200-FH36 . . . .C59 XMSW SERIES
YOWEA200-FH37 . . . .C59 XMSW SERIES
YOWEA200-FH38 . . . .C59 XMSW SERIES
YOWEA200-FH39 . . . .C59 XMSW SERIES
YOWEA200-FH40 . . . .C59 XMSW SERIES
YOWEA200-FH41 . . . .C59 XMSW SERIES
YOWEA200-FH42 . . . .C59 XMSW SERIES
YOWEA200-FH43 . . . .C59 XMSW SERIES
YOWEA200-FH44 . . . .C59 XMSW SERIES
YOWEA200-FH45 . . . .C59 XMSW SERIES
YOWEA200-FH46 . . . .C59 XMSW SERIES
YOWEA200-FH47 . . . .C59 XMSW SERIES
YOWEA200-FH48 . . . .C59 XMSW SERIES
YOWEA200-FH49 . . . .C59 XMSW SERIES
YOWEA200-FH50 . . . .C59 XMSW SERIES
YOWEA200-FH51 . . . .C59 XMSW SERIES
YOWEA200-FH52 . . . .C59 XMSW SERIES
YOWEA200-FH53 . . . .C59 XMSW SERIES
YOWEA200-FH54 . . . .C59 XMSW SERIES
YOWEA200-FH55 . . . .C59 XMSW SERIES
YOWEA200-FH56 . . . .C59 XMSW SERIES
YOWEA200-FH57 . . . .C59 XMSW SERIES
YOWEOT2B . . . . . . . . .C27 X/XCS SERIES
YOWEOT2D . . . . . . . . .C27 X/XCS SERIES
ZHLN-170 . . . . . . . . . . .F85 ZHLN SERIES
ZHLN-270 . . . . . . . . . . .F85 ZHLN SERIES
ZHLN-370 . . . . . . . . . . .F85 ZHLN SERIES
ZHLN-470 . . . . . . . . . . .F85 ZHLN SERIES
ZHLN-570 . . . . . . . . . . .F85 ZHLN SERIES
ZHLN-670 . . . . . . . . . . .F85 ZHLN SERIES
ZHLN-770 . . . . . . . . . . .F85 ZHLN SERIES
ZHLN-870 . . . . . . . . . . .F85 ZHLN SERIES
ZHLN-970 . . . . . . . . . . .F85 ZHLN SERIES
ZN102 . . . . . . . . . . . . . .F74 Z SERIES
ZN102CR . . . . . . . . . . .F76 Z SERIES
ZN102CR-EX . . . . . . . .F80 Z SERIES
ZN102-EX . . . . . . . . . . .F78 Z SERIES
ZN103 . . . . . . . . . . . . . .F74 Z SERIES
ZN103CR . . . . . . . . . . .F76 Z SERIES
ZN103CR-EX . . . . . . . .F80 Z SERIES
ZN103-EX . . . . . . . . . . .F78 Z SERIES
ZN103-EX-MG . . . . . . .F79 Z SERIES
ZN103-MG . . . . . . . . . .F75 Z SERIES
ZN105 . . . . . . . . . . . . . .F74 Z SERIES
ZN105CR . . . . . . . . . . .F76 Z SERIES
ZN105CR-EX . . . . . . . .F80 Z SERIES
ZN105CR-EX-MG . . . .F81 Z SERIES
ZN105-EX . . . . . . . . . . .F78 Z SERIES
ZN105-EX-MG . . . . . . .F79 Z SERIES
ZN105-MG . . . . . . . . . .F75 Z SERIES
ZN108 . . . . . . . . . . . . . .F74 Z SERIES
ZN108CR . . . . . . . . . . .F76 Z SERIES
ZN108CR-EX . . . . . . . .F80 Z SERIES
ZN108CR-EX-MG . . . .F81 Z SERIES
ZN108-EX . . . . . . . . . . .F78 Z SERIES
ZN108-EX-MG . . . . . . .F79 Z SERIES
ZN108-MG . . . . . . . . . .F75 Z SERIES
ZN109 . . . . . . . . . . . . . .F74 Z SERIES
ZN109CR . . . . . . . . . . .F76 Z SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
INTRODUCTION
NUMERIC INDEX
N16
ZN109CR-EX . . . . . . . .F80 Z SERIES
ZN109-EX . . . . . . . . . . .F78 Z SERIES
ZN109-EX-MG . . . . . . .F79 Z SERIES
ZN109-MG . . . . . . . . . .F75 Z SERIES
ZN208 . . . . . . . . . . . . . .F74 Z SERIES
ZN208CR . . . . . . . . . . .F76 Z SERIES
ZN208CR-EX . . . . . . . .F80 Z SERIES
ZN208CR-EX-MG . . . .F81 Z SERIES
ZN208-EX . . . . . . . . . . .F78 Z SERIES
ZN208-EX-MG . . . . . . .F79 Z SERIES
ZN208-MG . . . . . . . . . .F75 Z SERIES
ZN209 . . . . . . . . . . . . . .F74 Z SERIES
ZN209CR . . . . . . . . . . .F76 Z SERIES
ZN209CR-EX . . . . . . . .F80 Z SERIES
ZN209CR-EX-MG . . . .F81 Z SERIES
ZN209-EX . . . . . . . . . . .F78 Z SERIES
ZN209-EX-MG . . . . . . .F79 Z SERIES
ZN209-MG . . . . . . . . . .F75 Z SERIES
ZN210 . . . . . . . . . . . . . .F74 Z SERIES
ZN210CR . . . . . . . . . . .F76 Z SERIES
ZN210CR-EX . . . . . . . .F80 Z SERIES
ZN210CR-EX-MG . . . .F81 Z SERIES
ZN210-EX . . . . . . . . . . .F78 Z SERIES
ZN210-EX-MG . . . . . . .F79 Z SERIES
ZN210-MG . . . . . . . . . .F75 Z SERIES
ZN211 . . . . . . . . . . . . . .F74 Z SERIES
ZN211CR . . . . . . . . . . .F76 Z SERIES
ZN211CR-EX . . . . . . . .F80 Z SERIES
ZN211-EX . . . . . . . . . . .F78 Z SERIES
ZN211-EX-MG . . . . . . .F79 Z SERIES
ZN211-MG . . . . . . . . . .F75 Z SERIES
ZN309 . . . . . . . . . . . . . .F74 Z SERIES
ZN309-EX . . . . . . . . . . .F78 Z SERIES
ZN310 . . . . . . . . . . . . . .F74 Z SERIES
ZN310CR . . . . . . . . . . .F76 Z SERIES
ZN310CR-EX . . . . . . . .F80 Z SERIES
ZN310CR-EX-MG . . . .F81 Z SERIES
ZN310-EX . . . . . . . . . . .F78 Z SERIES
ZN311 . . . . . . . . . . . . . .F74 Z SERIES
ZN311CR . . . . . . . . . . .F76 Z SERIES
ZN311CR-EX . . . . . . . .F80 Z SERIES
ZN311CR-EX-MG . . . .F81 Z SERIES
ZN311-EX . . . . . . . . . . .F78 Z SERIES
ZN312 . . . . . . . . . . . . . .F74 Z SERIES
ZN312CR . . . . . . . . . . .F76 Z SERIES
ZN312CR-EX . . . . . . . .F80 Z SERIES
ZN312-EX . . . . . . . . . . .F78 Z SERIES
ZN313 . . . . . . . . . . . . . .F74 Z SERIES
ZN313-EX . . . . . . . . . . .F78 Z SERIES
ZN412 . . . . . . . . . . . . . .F74 Z SERIES
ZN412-EX . . . . . . . . . . .F78 Z SERIES
ZN413 . . . . . . . . . . . . . .F74 Z SERIES
ZN413-EX . . . . . . . . . . .F78 Z SERIES
ZN414 . . . . . . . . . . . . . .F74 Z SERIES
ZN414-EX . . . . . . . . . . .F78 Z SERIES
ZN415 . . . . . . . . . . . . . .F74 Z SERIES
ZN415-EX . . . . . . . . . . .F78 Z SERIES
ZN513 . . . . . . . . . . . . . .F74 Z SERIES
ZN513-EX . . . . . . . . . . .F78 Z SERIES
ZN515 . . . . . . . . . . . . . .F74 Z SERIES
ZN515-EX . . . . . . . . . . .F78 Z SERIES
ZN616 . . . . . . . . . . . . . .F74 Z SERIES
ZN616-EX . . . . . . . . . . .F78 Z SERIES
ZS001 . . . . . . . . . . . . . .F73 Z SERIES
ZS001-EX . . . . . . . . . . .F77 Z SERIES
ZS002 . . . . . . . . . . . . . .F73 Z SERIES
ZS002CR . . . . . . . . . . .F76 Z SERIES
ZS002CR-EX . . . . . . . .F80 Z SERIES
ZS002-EX . . . . . . . . . . .F77 Z SERIES
ZS003 . . . . . . . . . . . . . .F73 Z SERIES
ZS003CR . . . . . . . . . . .F76 Z SERIES
ZS003CR-EX . . . . . . . .F80 Z SERIES
ZS003CR-EX-MG . . . . .F81 Z SERIES
ZS003-EX . . . . . . . . . . .F77 Z SERIES
ZS004 . . . . . . . . . . . . . .F73 Z SERIES
ZS004CR . . . . . . . . . . .F76 Z SERIES
ZS004CR-EX . . . . . . . .F80 Z SERIES
ZS004CR-EX-MG . . . . .F81 Z SERIES
ZS004-EX . . . . . . . . . . .F77 Z SERIES
ZS004-EX-MG . . . . . . .F79 Z SERIES
ZS004-MG . . . . . . . . . .F75 Z SERIES
ZS006 . . . . . . . . . . . . . .F73 Z SERIES
ZS006CR . . . . . . . . . . .F76 Z SERIES
ZS006CR-EX . . . . . . . .F80 Z SERIES
ZS006CR-EX-MG . . . . .F81 Z SERIES
ZS006-EX . . . . . . . . . . .F77 Z SERIES
ZS006-EX-MG . . . . . . .F79 Z SERIES
ZS006-MG . . . . . . . . . .F75 Z SERIES
ZS007 . . . . . . . . . . . . . .F73 Z SERIES
ZS007CR . . . . . . . . . . .F76 Z SERIES
ZS007CR-EX . . . . . . . .F80 Z SERIES
ZS007-EX . . . . . . . . . . .F77 Z SERIES
ZS007-EX-MG . . . . . . .F79 Z SERIES
ZS007-MG . . . . . . . . . .F75 Z SERIES
ZS101 . . . . . . . . . . . . . .F73 Z SERIES
ZS101CR . . . . . . . . . . .F76 Z SERIES
ZS101CR-EX . . . . . . . .F80 Z SERIES
ZS101-EX . . . . . . . . . . .F77 Z SERIES
ZS102 . . . . . . . . . . . . . .F73 Z SERIES
ZS102CR . . . . . . . . . . .F76 Z SERIES
ZS102CR-EX . . . . . . . .F80 Z SERIES
ZS102-EX . . . . . . . . . . .F77 Z SERIES
ZS103 . . . . . . . . . . . . . .F73 Z SERIES
ZS103CR . . . . . . . . . . .F76 Z SERIES
ZS103CR-EX . . . . . . . .F80 Z SERIES
ZS103CR-EX-MG . . . . .F81 Z SERIES
ZS103-EX . . . . . . . . . . .F77 Z SERIES
ZS103-EX-MG . . . . . . .F79 Z SERIES
ZS103-MG . . . . . . . . . .F75 Z SERIES
ZS105 . . . . . . . . . . . . . .F73 Z SERIES
ZS105CR . . . . . . . . . . .F76 Z SERIES
ZS105CR-EX . . . . . . . .F80 Z SERIES
ZS105CR-EX-MG . . . . .F81 Z SERIES
ZS105-EX . . . . . . . . . . .F77 Z SERIES
ZS105-EX-MG . . . . . . .F79 Z SERIES
ZS105-MG . . . . . . . . . .F75 Z SERIES
ZS108 . . . . . . . . . . . . . .F73 Z SERIES
ZS108CR . . . . . . . . . . .F76 Z SERIES
ZS108CR-EX . . . . . . . .F80 Z SERIES
ZS108CR-EX-MG . . . . .F81 Z SERIES
ZS108-EX . . . . . . . . . . .F77 Z SERIES
ZS108-EX-MG . . . . . . .F79 Z SERIES
ZS108-MG . . . . . . . . . .F75 Z SERIES
ZS109 . . . . . . . . . . . . . .F73 Z SERIES
ZS109CR . . . . . . . . . . .F76 Z SERIES
ZS109CR-EX . . . . . . . .F80 Z SERIES
ZS109-EX . . . . . . . . . . .F77 Z SERIES
ZS109-EX-MG . . . . . . .F79 Z SERIES
ZS109-MG . . . . . . . . . .F75 Z SERIES
ZS110 . . . . . . . . . . . . . .F73 Z SERIES
ZS110-EX . . . . . . . . . . .F77 Z SERIES
ZS110-EX-MG . . . . . . .F79 Z SERIES
ZS110-MG . . . . . . . . . .F75 Z SERIES
ZS111 . . . . . . . . . . . . . .F73 Z SERIES
ZS111-EX . . . . . . . . . . .F77 Z SERIES
ZS111-EX-MG . . . . . . .F79 Z SERIES
ZS111-MG . . . . . . . . . .F75 Z SERIES
ZS201 . . . . . . . . . . . . . .F73 Z SERIES
ZS201-EX . . . . . . . . . . .F77 Z SERIES
ZS202 . . . . . . . . . . . . . .F73 Z SERIES
ZS202-EX . . . . . . . . . . .F77 Z SERIES
ZS203 . . . . . . . . . . . . . .F73 Z SERIES
ZS203-EX . . . . . . . . . . .F77 Z SERIES
ZS203-EX-MG . . . . . . .F79 Z SERIES
ZS203-MG . . . . . . . . . .F75 Z SERIES
ZS205 . . . . . . . . . . . . . .F73 Z SERIES
ZS205-EX . . . . . . . . . . .F77 Z SERIES
ZS205-EX-MG . . . . . . .F79 Z SERIES
ZS205-MG . . . . . . . . . .F75 Z SERIES
ZS208 . . . . . . . . . . . . . .F73 Z SERIES
ZS208CR . . . . . . . . . . .F76 Z SERIES
ZS208CR-EX . . . . . . . .F80 Z SERIES
ZS208CR-EX-MG . . . . .F81 Z SERIES
ZS208-EX . . . . . . . . . . .F77 Z SERIES
ZS208-EX-MG . . . . . . .F79 Z SERIES
ZS208-MG . . . . . . . . . .F75 Z SERIES
ZS209 . . . . . . . . . . . . . .F73 Z SERIES
ZS209CR . . . . . . . . . . .F76 Z SERIES
ZS209CR-EX . . . . . . . .F80 Z SERIES
ZS209CR-EX-MG . . . . .F81 Z SERIES
ZS209-EX . . . . . . . . . . .F77 Z SERIES
ZS209-EX-MG . . . . . . .F79 Z SERIES
ZS209-MG . . . . . . . . . .F75 Z SERIES
ZS210 . . . . . . . . . . . . . .F73 Z SERIES
ZS210CR . . . . . . . . . . .F76 Z SERIES
ZS210CR-EX . . . . . . . .F80 Z SERIES
ZS210CR-EX-MG . . . . .F81 Z SERIES
ZS210-EX . . . . . . . . . . .F77 Z SERIES
ZS210-EX-MG . . . . . . .F79 Z SERIES
ZS210-MG . . . . . . . . . .F75 Z SERIES
ZS211 . . . . . . . . . . . . . .F73 Z SERIES
ZS211CR . . . . . . . . . . .F76 Z SERIES
ZS211CR-EX . . . . . . . .F80 Z SERIES
ZS211-EX . . . . . . . . . . .F77 Z SERIES
ZS211-EX-MG . . . . . . .F79 Z SERIES
ZS211-MG . . . . . . . . . .F75 Z SERIES
ZS308 . . . . . . . . . . . . . .F73 Z SERIES
ZS308CR . . . . . . . . . . .F76 Z SERIES
ZS308CR-EX . . . . . . . .F80 Z SERIES
ZS308-EX . . . . . . . . . . .F77 Z SERIES
ZS308-EX-MG . . . . . . .F79 Z SERIES
ZS308-MG . . . . . . . . . .F75 Z SERIES
ZS309 . . . . . . . . . . . . . .F73 Z SERIES
ZS309CR . . . . . . . . . . .F76 Z SERIES
ZS309CR-EX . . . . . . . .F80 Z SERIES
ZS309CR-EX-MG . . . . .F81 Z SERIES
ZS309-EX . . . . . . . . . . .F77 Z SERIES
ZS309-EX-MG . . . . . . .F79 Z SERIES
ZS309-MG . . . . . . . . . .F75 Z SERIES
ZS310 . . . . . . . . . . . . . .F73 Z SERIES
ZS310CR . . . . . . . . . . .F76 Z SERIES
ZS310CR-EX . . . . . . . .F80 Z SERIES
ZS310CR-EX-MG . . . . .F81 Z SERIES
ZS310-EX . . . . . . . . . . .F77 Z SERIES
ZS310-EX-MG . . . . . . .F79 Z SERIES
ZS310-MG . . . . . . . . . .F75 Z SERIES
ZS311 . . . . . . . . . . . . . .F73 Z SERIES
ZS311CR . . . . . . . . . . .F76 Z SERIES
ZS311CR-EX . . . . . . . .F80 Z SERIES
ZS311CR-EX-MG . . . . .F81 Z SERIES
ZS311-EX . . . . . . . . . . .F77 Z SERIES
ZS311-EX-MG . . . . . . .F79 Z SERIES
ZS311-MG . . . . . . . . . .F75 Z SERIES
ZS312 . . . . . . . . . . . . . .F73 Z SERIES
ZS312CR . . . . . . . . . . .F76 Z SERIES
ZS312CR-EX . . . . . . . .F80 Z SERIES
ZS312CR-EX-MG . . . . .F81 Z SERIES
ZS312-EX . . . . . . . . . . .F77 Z SERIES
ZS312-EX-MG . . . . . . .F79 Z SERIES
ZS312-MG . . . . . . . . . .F75 Z SERIES
ZS313 . . . . . . . . . . . . . .F73 Z SERIES
ZS313CR . . . . . . . . . . .F76 Z SERIES
ZS313CR-EX . . . . . . . .F80 Z SERIES
ZS313-EX . . . . . . . . . . .F77 Z SERIES
ZS313-EX-MG . . . . . . .F79 Z SERIES
ZS313-MG . . . . . . . . . .F75 Z SERIES
ZS314 . . . . . . . . . . . . . .F73 Z SERIES
ZS314-EX . . . . . . . . . . .F77 Z SERIES
ZS315 . . . . . . . . . . . . . .F73 Z SERIES
ZS315-EX . . . . . . . . . . .F77 Z SERIES
ZS411 . . . . . . . . . . . . . .F73 Z SERIES
ZS411-EX . . . . . . . . . . .F77 Z SERIES
ZS412 . . . . . . . . . . . . . .F73 Z SERIES
ZS412-EX . . . . . . . . . . .F77 Z SERIES
ZS413 . . . . . . . . . . . . . .F73 Z SERIES
ZS413-EX . . . . . . . . . . .F77 Z SERIES
ZS414 . . . . . . . . . . . . . .F73 Z SERIES
ZS414-EX . . . . . . . . . . .F77 Z SERIES
ZS415 . . . . . . . . . . . . . .F73 Z SERIES
ZS415-EX . . . . . . . . . . .F77 Z SERIES
ZS511 . . . . . . . . . . . . . .F73 Z SERIES
ZS511-EX . . . . . . . . . . .F77 Z SERIES
ZS512 . . . . . . . . . . . . . .F73 Z SERIES
ZS512-EX . . . . . . . . . . .F77 Z SERIES
ZS513 . . . . . . . . . . . . . .F73 Z SERIES
ZS513-EX . . . . . . . . . . .F77 Z SERIES
ZS514 . . . . . . . . . . . . . .F73 Z SERIES
ZS514-EX . . . . . . . . . . .F77 Z SERIES
ZS515 . . . . . . . . . . . . . .F73 Z SERIES
ZS515-EX . . . . . . . . . . .F77 Z SERIES
ZS516 . . . . . . . . . . . . . .F73 Z SERIES
ZS516-EX . . . . . . . . . . .F77 Z SERIES
ZS517 . . . . . . . . . . . . . .F73 Z SERIES
ZS517-EX . . . . . . . . . . .F77 Z SERIES
ZS518 . . . . . . . . . . . . . .F73 Z SERIES
ZS518-EX . . . . . . . . . . .F77 Z SERIES
ZS520 . . . . . . . . . . . . . .F73 Z SERIES
ZS520-EX . . . . . . . . . . .F77 Z SERIES
ZS615 . . . . . . . . . . . . . .F73 Z SERIES
ZS615-EX . . . . . . . . . . .F77 Z SERIES
ZS616 . . . . . . . . . . . . . .F73 Z SERIES
ZS616-EX . . . . . . . . . . .F77 Z SERIES
ZS617 . . . . . . . . . . . . . .F73 Z SERIES
ZS617-EX . . . . . . . . . . .F77 Z SERIES
ZS618 . . . . . . . . . . . . . .F73 Z SERIES
ZS618-EX . . . . . . . . . . .F77 Z SERIES
ZS619 . . . . . . . . . . . . . .F73 Z SERIES
ZS619-EX . . . . . . . . . . .F77 Z SERIES
ZS620 . . . . . . . . . . . . . .F73 Z SERIES
ZS620-EX . . . . . . . . . . .F77 Z SERIES
ZS621 . . . . . . . . . . . . . .F73 Z SERIES
ZS621-EX . . . . . . . . . . .F77 Z SERIES
ZS622 . . . . . . . . . . . . . .F73 Z SERIES
ZS622-EX . . . . . . . . . . .F77 Z SERIES
ZS623 . . . . . . . . . . . . . .F73 Z SERIES
ZS623-EX . . . . . . . . . . .F77 Z SERIES
ZS624 . . . . . . . . . . . . . .F73 Z SERIES
ZS624-EX . . . . . . . . . . .F77 Z SERIES
ZS719 . . . . . . . . . . . . . .F73 Z SERIES
ZS719-EX . . . . . . . . . . .F77 Z SERIES
ZS721 . . . . . . . . . . . . . .F73 Z SERIES
ZS721-EX . . . . . . . . . . .F77 Z SERIES
ZS722 . . . . . . . . . . . . . .F73 Z SERIES
ZS722-EX . . . . . . . . . . .F77 Z SERIES
ZS723 . . . . . . . . . . . . . .F73 Z SERIES
ZS723-EX . . . . . . . . . . .F77 Z SERIES
ZS724 . . . . . . . . . . . . . .F73 Z SERIES
ZS724-EX . . . . . . . . . . .F77 Z SERIES
ZS725 . . . . . . . . . . . . . .F73 Z SERIES
ZS725-EX . . . . . . . . . . .F77 Z SERIES
ZS819 . . . . . . . . . . . . . .F73 Z SERIES
ZS819-EX . . . . . . . . . . .F77 Z SERIES
ZS822 . . . . . . . . . . . . . .F73 Z SERIES
ZS822-EX . . . . . . . . . . .F77 Z SERIES
ZS823 . . . . . . . . . . . . . .F73 Z SERIES
ZS823-EX . . . . . . . . . . .F77 Z SERIES
ZS824 . . . . . . . . . . . . . .F73 Z SERIES
ZS824-EX . . . . . . . . . . .F77 Z SERIES
ZS825 . . . . . . . . . . . . . .F73 Z SERIES
ZS825-EX . . . . . . . . . . .F77 Z SERIES
ZS826 . . . . . . . . . . . . . .F73 Z SERIES
ZS826-EX . . . . . . . . . . .F77 Z SERIES
ZS827 . . . . . . . . . . . . . .F73 Z SERIES
ZS827-EX . . . . . . . . . . .F77 Z SERIES
ZS828 . . . . . . . . . . . . . .F73 Z SERIES
ZS828-EX . . . . . . . . . . .F77 Z SERIES
ZS829 . . . . . . . . . . . . . .F73 Z SERIES
ZS829-EX . . . . . . . . . . .F77 Z SERIES
PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP. PART # SEC./PG PROD.GRP.
INTRODUCTION
HAZARDOUS LOCATION DATA H1
HAZARDOUS (CLASSIFIED) LOCATIONS
Hazardous locations are those locations where fire or explosion
hazards may exist due to flammable gases or vapors, flamma-
ble liquids, combustible dust, or ignitible fibers or flyings.
Although flammable gases and vapors, and combustible dusts,
exist almost everywhere, they are usually present only in minute
quantities, much less than necessary for a fire or explosion haz-
ard to exist. Thus, the presence of a flammable gas or vapor, or
combustible dust, does not in itself define a hazardous location.
These materials must be present in sufficient quantities (con-
centrations) to present a potential explosion hazard.
Locations where there is an explosion hazard because of the
presence of high explosives, such as blasting agents and
munitions, are not classified as hazardous locations. There are
standards covering the handling and use of such materials,
and some of these require electrical equipment suitable for use
in hazardous locations. This is because such equipment pro-
vides a greater degree of safety than ordinary location or gen-
eral purpose equipment, not because such equipment has
been tested for use in the presence of high explosives.
In a like manner, locations made hazardous because of the
presence of pyrophoric materials, such as some phosphorous
compounds and finely divided metal powders are not classified
as hazardous locations. Pyrophoric is defined in the dictionary
as “igniting spontaneously” or “emitting sparks when scratched
or struck, especially with steel”. Where pyrophoric material or
high explosives are present, precautions beyond those in the
electrical codes are necessary.
UNDERSTANDING
“GLOBAL” HAZARDOUS LOCATIONS
The evolution of hazardous location electrical codes and stan-
dards throughout the world has taken two distinct paths. In
North America, a “Class, Division” System has been used for
decades as the basis for area classification of hazardous (clas-
sified) locations. Because the hazards and methods of protect-
ing electrical equipment against these hazards differ for differ-
ent materials, hazardous locations are divided into three
Classes, and two Divisions. The Classes are based on the type
of hazard and the explosive characteristics of the material with
the Divisions being based on the occurance or risk of fire or
explosion that the material presents. While Canada and the
United States have some differences in acceptable wiring
methods and product standards, their systems are very similar.
In other parts of the world, areas containing potentially explo-
sive atmospheres are dealt with using a “Zone System”. Zones
are based predominately on the International Electrotechnical
Commission (IEC) and the European Committee for
Electrotechnical Standardization (CENELEC) standards.
Whereas North America deals with multiple types of hazardous
atmospheres, the Zone system presently addresses only flam-
mable gases and vapors which is the equivalent to North
Americas Class I locations.The most significant difference
between the Zone system is that the level of hazard probability
is divided into three Zones as opposed to two Divisions.
While specific requirements differ, the United States and Canada
have incorporated the Zone System for Class I, hazardous loca-
tions into their recent electrical code updates. Both systems pro-
vide effective solutions for electrical equipment used in haz-
ardous locations and both have excellent safety records.
In North America Hazardous (Classified) Locations are divided
into three Classes based on the explosive characteristics of the
material. The Classes of material are further divided into
“Divisions” or “Zones” based on the risk of fire or explosion that
the material presents. The Zone system has three levels of haz-
ard whereas the Division system has two levels.
The table below provides a comparison between the “Class,
Division” System and the “Zone” System.
1The United States and Canada have adopted Zones for Gases and Vapors.
HAZARDOUS (CLASSIFIED) LOCATIONS
CLASS I LOCATIONS
Class I locations are those in which flammable gases or vapors
are or may be present in the air in quantities sufficient to pro-
duce explosive or ignitible mixtures.
The term “gases or vapors” is used because of common usage
in the English language. The term “gases” is commonly used to
refer to materials that are in a gaseous state under normal
atmospheric conditions, such as hydrogen and methane. The
term “vapors” refers to the gases over a material that is a liquid
under normal atmospheric conditions (such as gasoline) but
which emits gases within the flammable range under these
same atmospheric conditions.
CLASS I, DIVISIONS 1 AND 2
GROUPS A, B, C, AND D LOCATIONS
General
The subdivision of Class I into two divisions identifies the likeli-
hood or risk that an ignitible concentration of gases or vapors
will be in the location. Division 1 identifies locations where the
risk is high or medium. Division 2 identifies locations where
there is a small but still finite risk. If the risk is extremely low,
HAZARDOUS MATERIAL
Gases or Vapors1
CLASS, DIVISION SYSTEM
Class I, Div. 1
Class I, Div. 2
ZONE SYSTEM
Zone 0 & Zone 1
Zone 2
INTRODUCTION
HAZARDOUS LOCATION DATA
H2
FREQUENCY OF
OCCURRENCE
Continuous
Intermittent Periodically
Abnormal Conditions
CLASS, DIVISION SYSTEM
Class I, Div. 1
Class I, Div. 2
ZONE SYSTEM
Zone 0
Zone 1
Zone 2
the location is not considered a hazardous location. Such a
location is typified by a single family home with natural gas or
propane as the energy source for heating. The gas could, and
on extremely rare occasions does leak into the home, and an
explosion occurs. However the risk is so low (because of the
safety systems built into the gas supply and heating equipment)
that such locations are not classified as a hazardous location.
Division 1
Class I, Division 1 locations are those where the explosion haz-
ard exists under normal operating conditions. The area may be
hazardous all or most of the time, or it may only be hazardous
some of the time. Division 1 also includes locations where
breakdown or faulty operation of electrical equipment or
processes might release ignitible concentrations of flammable
gases or vapors, and might also cause simultaneous failure of
electrical equipment in such a way as to directly cause the
electrical equipment to become a source of ignition. An exam-
ple of such a location might be an area where a flammable liq-
uid is stored under cryogenic conditions, and a leak of the
extremely low temperature liquid directly onto electrical equip-
ment could cause failure of the electrical equipment at the
same time the vapors of the evaporating liquid are within the
flammable range.
Division 2
Class I, Division 2 locations are those where ignitible concentra-
tions of flammable gases or vapors are not normally present, but
could be present in the event of a fault, such as a leak at a valve
in a pipeline carrying flammable liquids. Division 2 locations also
often exist around Division 1 locations where there is no barrier
or partition to separate the Division 1 space from a nonhazard-
ous location, or where ventilation failure (an abnormal condition)
might extend the area where flammables exist under normal con-
ditions. Electrical equipment approved for Class I, Division 1
locations is also suitable for use in Division 2 locations.
The frequency of occurance determines the level of hazard
for a location, the longer the material is present, the greater
the risk.
The abnormal conditions of occurrence, or lower risk areas,
Division 2 and Zone 2 are basically identical in the Zone and
Division system. However, in areas where a hazard is expected
to occur during normal operation, Division 1 and Zone 1 and 0,
the Zone system deals with highest risk areas Zone 0 separate-
ly, and risk associated with the remaining location Zone 1, is
considered lower. The Division system tends to be less specific
in its consideration of Division 1. The Division system treats all
areas where a hazard is expected to occur in normal operation
the same.
The following chart illustrates the differences between the
various Zones.
The illustration below compares the Division and Zone systems
in terms of risk assessment.
GRADE OF RELEASE ZONE FLAMMABLE MIXTURE PRESENT
Continuous 0 1000 hours per year or more (10%)
Primary 1 Between 10 and 1000 hours per year
or more ( 0.1% to 10% )
Secondary 2 Less than 10 hours per year
( 0.01% to 0.1% )
Unclassified - Less than 1 hour per year
( Less than 0.01% ) (1)
This is a combination of Tables 2 and 3 from API RP505
(1) The 1-hour per year in API RP505 is considered to be high by some
industry experts.
INTRODUCTION
HAZARDOUS LOCATION DATA H3
CLASS I, GROUPS A, B, C, AND D
Class I locations are divided into groups because different
materials have different explosion and ignition characteristics.
The grouping permits equipment to be tested based on the
type of flammable material in which it is intended to be used.
It also permits area classification to be based on the type of
material anticipated in that location.
The grouping is based on two major factors: the explosion
pressure generated during an explosion; and the maximum
gap between ground flat mating metal surfaces that will prevent
propagation of an explosion through the gap to a flammable
atmosphere of the same flammable material and concentration.
Group A
The highest explosion pressures of the materials grouped are
generated by acetylene, the only material in Group A. Thus,
explosionproof equipment designed for Group A must be very
strong to withstand the explosion anticipated, and must have a
very small gap between joint surfaces. Explosionproof equip-
ment for Group A is the most difficult to design and there is less
explosionproof equipment listed for this group than for any
other group.
Group B
Group B materials produce explosion pressures somewhat less
than acetylene, and the design of explosionproof enclosures for
this group is somewhat less rigorous than for Group A enclo-
sures. However, because of the very high explosion pressures
in both Groups A and B, and, in particular, the very small gap
between mating surfaces needed to prevent propagation of an
explosion, there are no explosionproof motors listed for use in
either Group A or B locations.
Group C
The chemical materials in Group C fall within the range
between Groups B and D in both the explosion pressures
generated and the gap between mating surfaces of explo-
sion proof equipment that will prevent an explosion.
Group D
Group D is the most common group encountered in the field,
and there is more equipment available for this group than for
any other group.
There is no consistent relationship between such properties as
ignition temperature, flash point, and flammable limits, and the
Class I hazardous location group into which the various
materials fall.
General
This method of area classification follows the international
method of area classification as developed by the International
Electrotechnical Commission (IEC) and European Committee
for Electrotechnical Standardization (CENELEC) standards.
Like the subdivisions under Class I locations of Divisions 1 and
2 and for the same reasons, (area classification and equipment
testing) hazardous locations are classified by zones instead of
divisions.
Zone 0
These are locations in which ignitible concentrations of flamma-
ble gases or vapors are present continuously or for long peri-
ods of time. Zone 0 represents the most dangerous part of the
Division 1 classification.
There are situations where flammable liquids are stored in tanks
and the vapor space above the liquid is above the upper flam-
mable limit. If the vapor space is above the upper flammable limit
most of the time, the space is not a Zone 0 location because the
requirements are for “ignitible concentrations” of flammable
gases or vapors (concentrations within the flammable range).
Zone 1
These locations are almost the same as Class I, Division 1
locations in the class, division system except they do not
include those locations defined as Class I, Zone 0, where
ignitible concentrations are present all or most of the time.
Zone 2
These locations are the same as Class I, Division 2 locations in
the class, division system.
CLASS I, GROUPS IIC, IIB, AND IIA
General
In the international system of classification, Group I gas group-
ing is reserved for classification and equipment intended for
use in underground mines. For information on electrical equip-
ment in underground mines, see the Federal Register, regula-
tions of the Mine Safety and Health Administration (MSHA).
TYPICAL GAS
Acetylene
Hydrogen
Ethylene
Propane
Methane
CLASS, DIVISION
GAS GROUPS
A
B
C
D
D
ZONE GAS
GROUPS
IIC
IIC
IIB
IIA
IIA
CLASS I, ZONES 0, 1 AND 2,
GROUPS IIC,IIB, AND IIA, LOCATIONS
INTRODUCTION
HAZARDOUS LOCATION DATA
H4
Group IIC
This group is the equivalent of a combination of Class I, Groups A
and B gases and vapors in the Division system. In the internation-
al system of classification, only the gap between machined flat
mating surfaces, plus the igniting current (directly related to igni-
tion energy), is considered in grouping materials. Explosion pres-
sure is not one of the considerations. Thus, Groups A and B in the
class, division” system of classification can be grouped together
in the international system. Internationally, rigid metal conduit and
similar “pipe” wiring systems are not normally used in hazardous
locations and thus consideration of pressure piling through a
length of conduit (a major problem with acetylene) is unnecessary
in the zone system. The maximum safe gap between machined
flat mating surfaces is the same for Group A, and B materials.
Group IIB
This group is the equivalent to the Class I, Group C gases and
vapors in the Division system.
Group IIA
This group is equivalent to the Class I, Group D gases and
vapors in the Division system.
TEMPERATURE CODES (T-CODES)
Class I
The ignition temperature or auto-ignition temperature (AIT) is
the minimum temperature required to initiate or cause self-sus-
tained combustion in a substance without any apparent source
of ignition. The lowest published ignition temperature should be
the one used to determine the acceptability of equipment. This
is of particular concern when selecting heat producing equip-
ment such as lighting fixtures or motors which may generate
sufficient heat to ignite the surrounding atmosphere.
Class I and Class II, areas use T-Codes or are subject to maxi-
mum temperature limitations as shown in the following chart.
North America and the IEC are consistent in their temperature
or T-Codes. However unlike the IEC, North America includes
incremental values as shown below.
Ambient Temperature
The ambient temperature is the surrounding temperature of the
environment in which a piece of equipment is installed, whether
it is indoors or outdoors. Certain heat producing equipment
such as lighting fixtures list a Temperature Code or T-Code at a
given ambient temperature.
A heat producing product is considered acceptable for the
location, provided the minimum ignition temperature of the haz-
ardous material present and and the ambient temperature of
the location do not exceed the limits set by the manufacturer. If
the ambient temperature is higher than the maximum stated on
the name plate, it might still be acceptable to use the product
under certain conditions, provided the minimum ignition tem-
perature of the hazardous material has not been exceeded. In
all cases, consult the factory for assistance.
Operating Temperature
The rated operating temperature for hazardous (classified)
products is determined by conducting laboratory test in an
ambient temperature of 40° C. Products certified by the various
agencies consider products certified to their standards to be
suitable for different temperature ranges. The range for CSA is
–50° C to +40° C, the range for UL is –25° C to +40° C, and the
range for IEC and CENELEC is –20° C to +40° C.
CLASS II LOCATIONS
Class II locations are those that are hazardous because of the
presence of combustible dust. Note that the dust must be pre-
sent in sufficient quantities for a fire or explosion hazard to
exist. The fact that there is some combustible dust present
does not mean a Class II hazardous location exists. To be con-
sidered a “dust” the combustible material must exist as a finely
divided solid of 420 microns (0.420 mm) or less. Such a dust
will pass through a No. 40 U.S. sieve.
CLASS II, DIVISIONS 1 AND 2
GROUPS E, F, AND G LOCATIONS
General
Just as in Class I, Divisions 1 and 2, the subdivision of Class II
into Divisions 1 and 2 identifies the likelihood that there will be
an explosion hazard.
NORTH AMERICAN
TEMP. CODES US
(NEC-500) & CSA
IEC/CENELEC/US
(NEC 505) TEMP. CODES
MAXIMUM
TEMPERATURE
T1 T1 450 842
T2 T2 300 572
T2A 280 536
T2B 260 500
T2C 230 446
T2D 215 419
T3 T3 200 392
T3A 180 356
T3B 165 329
T3C 160 320
T4 T4 135 275
T4A 120 248
T5 T5 100 212
T6 T6 85 185
°C °F
INTRODUCTION
HAZARDOUS LOCATION DATA H5
Division 1
A Class II, Division 1 location is one where combustible dust is
normally in suspension in the air in sufficient quantities to pro-
duce ignitible mixtures, or where mechanical failure or abnor-
mal operation of equipment or machinery might cause an
explosive or ignitible dust-air mixture to be produced, and
might also provide a source of ignition through simultaneous
failure of electrical equipment. A Class II, Division 1 location
also exists where combustible dusts of an electrically conduc-
tive nature may be present in hazardous quantities (Group E
locations). The term “hazardous quantity” is intended to mean
those locations where the dust may not be in suspension in the
air in sufficient quantity to cause an explosion, but might have
settled on electrical equipment so that the electrically conduc-
tive particles can penetrate the openings in the electrical equip-
ment enclosure and cause an electrical failure, or where the
dust can get into motor bearings and cause excessive temper-
atures because of bearing failure.
Division 2
A Class ll, Division 2 location is one where combustible dust is
not normally in the air in quantities sufficient to produce explosive
or ignitible mixtures, and dust accumulations are not normally
sufficient to interfere with the normal operation of electrical equip-
ment, such as clogging ventilating openings or causing bearing
failure. It includes locations where combustible dust may be in
suspension in the air only as a result of infrequent malfunctioning
of handling or processing equipment, and those locations where
dust accumulation may be on or in the vicinity of the electrical
equipment and may be sufficient to interfere with the safe dissi-
pation of heat from the equipment, or may be ignitible by abnor-
mal operation or failure of the electrical equipment.
Class II, Groups E, F, and G
The division into three groups in Class II locations is for the
same reasons Class I locations are divided into Groups A, B, C,
and D: equipment design and area classification. However, the
three Class II groups are based on different characteristics than
the four Class I groups because the design of dust-ignition
proof equipment for Class II locations is based on different prin-
ciples than the design of explosion proof equipment for Class I
locations. In Class II locations the ignition temperature of the
dust, the electrical conductivity of the dust, and the thermal
blanketing effect the dust can have on heat-producing equip-
ment, such as lighting fixtures and motors are the deciding fac-
tors in determining the Class II group.
Group E
Group E dusts include the metal dusts, such as aluminum and
magnesium. In addition to being highly abrasive, and thus likely
to cause overheating of motor bearings if the dust gets into the
bearing, Group E dusts are electrically conductive. If they are
allowed to enter an enclosure, they can cause electrical failure
of the equipment.
Group F
The Group F dusts are carbonaceous, the primary dust in this
group being coal dust. These dusts have somewhat lower igni-
tion temperatures than the Group E dusts and a layer of a
Group F dust has a higher thermal insulating value than a layer
of a Group E dust, thus requiring more careful control of the
temperature on the surface of the equipment. Such dusts are
semi-conductive but this is not usually a factor for equipment
rated 600 volts and less.
Group G
The Group G dusts include plastic dusts, most chemical dusts,
and food and grain dusts. They are not electrically conductive.
These dusts, in general, have the highest thermal insulating
characteristics and the lowest ignition temperatures. Thus, dust-
ignitionproof equipment for use in Group G atmospheres must
have the lowest surface temperatures to prevent ignition of a
dust layer by the heat generated within the equipment.
Because of the different design characteristics, equipment
suitable for Class I locations is not necessarily suitable for
Class II locations, and equipment suitable for Class II loca-
tions is not necessarily suitable for Class I locations. The
equipment must be approved for each class and group of
location involved.
Much equipment suitable for Class I locations is also suitable
for Class II locations, and is so marked, although when used in
Class II locations there may be restrictions, such as lower maxi-
mum lamp wattage to maintain the lower surface temperature
needed for equipment in dust atmospheres.
In Class II areas all products must operate at temperatures as
shown below based on whether they are heat producing or
subject to overloading or not, and based on the Group which
they fall under. Class III products in all cases must operate
below 165° C.
TYPE OF MATERIAL
Electrically Conductive Dusts
Carbonaceous Dusts
Agricultural Dusts
GROUPS
E
F
G
TYPICAL MATERIALS
Powdered metals such as
aluminum or magnesium
Carbon Black, Coal Dust, Coke Dust
Grain, Flour, Sugars, Spices, Rice, Certain
Polymers
E 200 392 200 392 200 392
F 200 392 150 302 200 392
G 165 329 120 248 165 329
CLASS II
GROUPS °C °F °C °F °C °F
EQUIPMENT
THAT IS NOT
SUBJECT TO
OVERLOADING
EQUIPMENT (SUCH AS MOTORS
OR POWER TRANSFORMERS)
THAT MAY BE OVERLOADED
ABNORMAL
OPERATION
NORMAL
OPERATION
INTRODUCTION
HAZARDOUS LOCATION DATA
H6
Class III locations are those that are hazardous because of the
presence of easily ignitable fibers or flyings, but in which the
fibers or flyings are not likely to be in suspension in the air in
quantities sufficient to produce ignitible mixtures. Easily ignitible
fibers and flyings present a fire but not an explosion hazard. A
typical example of this type of material is the cotton lint that
accumulates in the lint trap of clothes dryers. Listed clothes
dryers are designed so that even if the lint ignites, the fire will
be contained within the dryer enclosure.
CLASS III, DIVISIONS 1 AND 2
Division 1
This is a location where the equipment producing the ignitible
fibers or flyings is located (near textile mill machinery, for exam-
ple) or where the material is handled (for example, where the
material is stuffed into bags).
Division 2
This is a location where the easily ignitible fibers are stored or han-
dled, except in manufacturing processes (which is Division 1).
Class III Groups
There are no groups in Class III locations.
The 2005 NEC introduced a new Article 506 that provides an
alternate zone system to Class II and Class III. This system,
based on the IEC, is for locations that inlcude combustible con-
centrations of combustible dust or ignitible fibers and flyings.
Zone 20. These are Hazardous (Classified) Locations where
areas of combustible dust or ignitible fibers and flyings are
present continuously or for long periods of time in quantities
sufficient to be hazardous, as classified by 506.5(B) (1) of the
2005 NEC.
Zone 21. These are Hazardous (Classified) Locations where
areas of combustible dust or ignitible fibers and flyings are
likely to exist occasionally under normal operation in quanti-
ties sufficient to be hazardous, as classified by 506.(B)(2) of
the 2005 NEC.
Zone 22. These are Hazardous (Classified) Locations where
areas of combustible dust or ignitible fibers and flyings are
not likely to occure under normal operation in quantities sufficient
to be hazardous, as classified by 506.5(B)(3) of the 2005 NEC.
NOTE: Zones 20, 21, and 22 do not apply to combustible metallic dusts.
There are a number of ways of protecting electrical equip-
ment so that it cannot cause an explosion when used in a
surrounding flammable atmosphere, or ignite a layer of dust
or fibers on the equipment. The two most common ways are
explosion- proof equipment in Class I, Division 1 and some
Division 2 locations and dust-ignitionproof equipment in
Class II, Division 1 locations. Flameproof and increased safe-
ty equipment is most common in Class I, Zone 1 locations.
Intrinsically safe equipment is becoming increasingly more
popular in Division 1 and Zone 1 locations. Most Killark
equipment for use in hazardous locations is designed to
meet the requirements for explosion proof and/or dust-igni-
tionproof apparatus.
The Fire Triangle
CLASS III LOCATIONS
EQUIPMENT DESIGN AND CONSTRUCTION
ZONES 20, 21, AND 22 L0CATIONS
In order for a fire or explosion to
occur three conditions must exist.
There must be a fuel (the flammable
gas or vapor, or combustible dust) in
ignitible quantities; there must also be
an ignition source (energy in the form
of heat or a spark) of sufficient energy
to cause ignition; and there must be
oxygen, usually the oxygen in the air.
These three conditions are called the fire triangle as shown.
Remove any one or more of these three and a fire or explo-
sion cannot occur. This is the basis of the various protection
systems for electrical equipment permitted in the electrical
codes for use in hazardous locations. These protection
methods either contain the internal explosion or eliminate
one or more of the fire triangle components necessary for
an explosion to occur.
The most common methods of protection used in North
America are explosion proof equipment for Class I locations,
and dust-ignition proof equipment for Class II locations.
The fuel and oxygen must be in the correct mixture, too little
fuel, or a lean mixture, or too much fuel, a rich mixture cannot
ignite. These explosive limits are defined as “Lower Explosive
Limit” (LEL) and “Upper Explosive Limit” (UEL).
EXPLOSION PROOF OR FLAMEPROOF
TYPE “D” PROTECTION
These protection types are based on containment. The re-
quirements for flameproof are somewhat less severe than the
North American requirements for explosionproof equipment.
Flameproof equipment is not permitted in Class I, Division 1
locations, and explosion proof equipment is not permitted in
Class I, Zone 0 locations.
Since flammable gases and vapors are expected to be
inside the enclosure the equipment design must be capable
of withstanding an explosion caused by a spark at the con-
tacts of switching devices, high temperature, or an electrical
fault. The enclosure is designed so that hot gases generated
during an internal explosion are cooled below the ignition
temperature of the surrounding flammable atmosphere as
they are transmitted through the joints of the enclosure.
In addition, the external surfaces of the enclosure must not
be hot enough to ignite the surrounding atmosphere as a
result of heat energy within the enclosure. This heat energy
may be the result of normal operation of heat-producing
equipment, or it may be the result of an electrical arc to the
enclosure from an arcing ground fault.
Oxygen
TYPES OF PROTECTION
Fuel
Fuel
Combustion
Combustion
Oxygen Ignition
Ignition
MOULDED/ENCAPSULATED TYPE “m” PROTECTION
This type of protection is one in which the parts than can ignite
an explosive atmosphere are enclosed in a resin (plastic) suffi-
ciently resistant to environmental influences in such a way that
this explosive atmosphere cannot be ignited by either sparking
or heating, which may occur within the encapsulation.
INCREASED SAFETY TYPE “e” PROTECTION
This protection system is for equipment that, under normal
operating conditions, does not produce ignition-capable arcs or
sparks or high temperatures. It provides special increased
spacing between live parts and live parts of opposite polarity or
grounded metal parts, special insulating materials to reduce the
likelihood of arc tracking, special terminals to reduce the likeli-
hood of high temperatures or loose connections, and tempera-
ture control on heat producing equipment. It is widely used for
protection of squirrel cage motors, terminal boxes, and the ter-
minals of flame proof components.
INTRINSIC SAFETY OR INTRINSICALLY SAFE TYPE
“ia”, AND “ib” PROTECTION
There are two versions of this protection method in the “Zone
System, “ia” (2 fault) for Zone 0 and less dangerous locations,
and “ib” (1 fault) for Zone 1 and 2 locations only. Additionally in
the “Class, Division” System intrinsically safe equipment listed
for use in Class I, Division 1 locations for the same gas group,
and with a suitable temperature rating is permitted in Class I,
Zone 0, 1 and 2 locations. There is no “i” marking for intrinsical-
ly safe equipment listed in the “Class, Division” System (2 fault
type only).
INTRINSICALLY SAFE SYSTEMS
These are low-energy systems designed to assure safety by
eliminating the ignition source leg of the fire triangle. The ener-
gy in the system is maintained below that needed to ignite the
flammable atmosphere, even under fault conditions. Opening,
grounding, or short-circuiting of field-installed wiring is consid-
ered a condition of normal operation in this protection tech-
nique, rather than a fault condition. The common protective
device used in intrinsically safe circuits is a Zener Diode Barrier.
While this type of device controls the energy going to a circuit,
it does not prevent incorrectly installed products such as
capacitors, which may store energy, from increasing the maxi-
mum current permitted in the system. It is important to under-
stand that intrinsic safety is a “system approach” and that no
single device provides total protection.
NON-SPARKING TYPE “nA” PROTECTION
This is protection suitable for use in Class I, Zone 2 or Division
2 locations only. It is subdivided into three categories, “nA”,
“nC” and “nR”.
A - Non-sparking equipment.
C - Sparking equipment in which the contacts are suitably
protected other than by restricted breathing.
R - Restricted breathing enclosure. This is similar to hermetically
sealed however it also includes other enclosures where the
rate of leaking of a flammable into the enclosure is restricted.
Special leak tests are conducted on the enclosure.
HERMETICALLY SEALED TYPE “nC” PROTECTION
This protection technique is limited to Zone 2 or Division 2 loca-
tions only and works by eliminating the ignition source leg of
the fire triangle. It defines “hermetically sealed” as a fusion
process such as soldering, brazing, welding, or the fusion of
glass to metal. So-called “hermetically sealed” relays that are
sealed by use of gaskets are not included in this definition.
Typical hermetically sealed devices are mercury-tube switches
and reed switches.
NON-INCENDIVE EQUIPMENT TYPE “nC” PROTECTION
This is a method of protection of sparking contacts in Class I,
Zone 2 or Division 2 locations. A non-incendive component is
one having contacts for making or breaking an incendive circuit
where the contact mechanism is constructed so that the com-
ponent is incapable of igniting the specified flammable gas or
vapor-air mixture. The housing of a non-incendive component is
not intended to exclude the flammable atmosphere or contain
an explosion.
OIL IMMERSION TYPE “o” PROTECTION
This protection technique is also limited to equipment in
Division 2 and Zone 1 and 2 locations. It eliminates the ignition
source leg of the fire triangle. It works because the ignition
source is maintained under oil. There are provisions for assur-
ing that there is always enough oil above the contacts to pre-
vent ignition of a flammable atmospheres This technique is
usually used for high-energy contacts, often rated over 600
volts, such as those in circuit breakers, motor controllers and
other industrial control equipment. It can, however, be used for
any switching device.
INTRODUCTION
HAZARDOUS LOCATION DATA H7
MOULDED/ENCAPSULATED TYPE “m” PROTECTION
This type of protection is one in which the parts than can ignite
an explosive atmosphere are enclosed in a resin (plastic) suffi-
ciently resistant to environmental influences in such a way that
this explosive atmosphere cannot be ignited by either sparking
or heating, which may occur within the encapsulation.
INCREASED SAFETY TYPE “e” PROTECTION
This protection system is for equipment that, under normal
operating conditions, does not produce ignition-capable arcs or
sparks or high temperatures. It provides special increased
spacing between live parts and live parts of opposite polarity or
grounded metal parts, special insulating materials to reduce the
likelihood of arc tracking, special terminals to reduce the likeli-
hood of high temperatures or loose connections, and tempera-
ture control on heat producing equipment. It is widely used for
protection of squirrel cage motors, terminal boxes, and the ter-
minals of flame proof components.
INTRINSIC SAFETY OR INTRINSICALLY SAFE TYPE
“ia”, AND “ib” PROTECTION
There are two versions of this protection method in the “Zone
System, “ia” (2 fault) for Zone 0 and less dangerous locations,
and “ib” (1 fault) for Zone 1 and 2 locations only. Additionally in
the “Class, Division” System intrinsically safe equipment listed
for use in Class I, Division 1 locations for the same gas group,
and with a suitable temperature rating is permitted in Class I,
Zone 0, 1 and 2 locations. There is no “i” marking for intrinsical-
ly safe equipment listed in the “Class, Division” System (2 fault
type only).
INTRINSICALLY SAFE SYSTEMS
These are low-energy systems designed to assure safety by
eliminating the ignition source leg of the fire triangle. The ener-
gy in the system is maintained below that needed to ignite the
flammable atmosphere, even under fault conditions. Opening,
grounding, or short-circuiting of field-installed wiring is consid-
ered a condition of normal operation in this protection tech-
nique, rather than a fault condition. The common protective
device used in intrinsically safe circuits is a Zener Diode Barrier.
While this type of device controls the energy going to a circuit,
it does not prevent incorrectly installed products such as
capacitors, which may store energy, from increasing the maxi-
mum current permitted in the system. It is important to under-
stand that intrinsic safety is a “system approach” and that no
single device provides total protection.
NON-SPARKING TYPE “nA” PROTECTION
This is protection suitable for use in Class I, Zone 2 or Division
2 locations only. It is subdivided into three categories, “nA”,
“nC” and “nR”.
A - Non-sparking equipment.
C - Sparking equipment in which the contacts are suitably
protected other than by restricted breathing.
R - Restricted breathing enclosure. This is similar to hermetically
sealed however it also includes other enclosures where the
rate of leaking of a flammable into the enclosure is restricted.
Special leak tests are conducted on the enclosure.
HERMETICALLY SEALED TYPE “nC” PROTECTION
This protection technique is limited to Zone 2 or Division 2 loca-
tions only and works by eliminating the ignition source leg of
the fire triangle. It defines “hermetically sealed” as a fusion
process such as soldering, brazing, welding, or the fusion of
glass to metal. So-called “hermetically sealed” relays that are
sealed by use of gaskets are not included in this definition.
Typical hermetically sealed devices are mercury-tube switches
and reed switches.
NON-INCENDIVE EQUIPMENT TYPE “nC” PROTECTION
This is a method of protection of sparking contacts in Class I,
Zone 2 or Division 2 locations. A non-incendive component is
one having contacts for making or breaking an incendive circuit
where the contact mechanism is constructed so that the com-
ponent is incapable of igniting the specified flammable gas or
vapor-air mixture. The housing of a non-incendive component is
not intended to exclude the flammable atmosphere or contain
an explosion.
OIL IMMERSION TYPE “o” PROTECTION
This protection technique is also limited to equipment in
Division 2 and Zone 1 and 2 locations. It eliminates the ignition
source leg of the fire triangle. It works because the ignition
source is maintained under oil. There are provisions for assur-
ing that there is always enough oil above the contacts to pre-
vent ignition of a flammable atmospheres This technique is
usually used for high-energy contacts, often rated over 600
volts, such as those in circuit breakers, motor controllers and
other industrial control equipment. It can, however, be used for
any switching device.
INTRODUCTION
HAZARDOUS LOCATION DATA
H8
PURGED AND PRESSURIZED TYPE “p” PROTECTION
This is a type of protection which prevents the entry of the sur-
rounding atmosphere into the enclosure of the electrical appa-
ratus by maintaining a positive pressure within the enclosure of
a protective gas (air, inert, or other suitable gas) at a higher
pressure than the surrounding atmosphere.
Purging is the process of supplying an enclosure with a protec-
tive gas at a sufficient flow and positive pressure to reduce the
concentration of any flammable gas or vapor initially present to
an acceptable level. This technique can be used to change a
Class I or Class II, Division 1 location into a nonhazardous loca-
tion or into a Division 2 location, or to change a Class I or II,
Division 2 location into a nonhazardous location. It requires a
noncombustible enclosure (which may be a control room or a
machine room) that is first purged of any combustibles or flam-
mables that may be present, and is then maintained at a posi-
tive pressure sufficient to assure that combustibles or flamma-
bles cannot enter the enclosure and be ignited by electrical
equipment within the enclosure. The purging may be a continu-
ous purge or a single purge with a positive pressure maintained
to make up for leaks. The pressurizing medium may be either
air, commonly used in a control room where people will be
working, or a nonflammable gas. In tanker ships at sea, flue
gas is a common purging and pressurizing medium. In instru-
ment enclosures in locations with corrosive atmospheres, spe-
cially processed and dried air or gas is used to protect the
enclosed equipment against corrosion as well as to provide
protection against ignition of exterior flammable gases and
vapors, or combustible dusts.
POWDER FILLING TYPE “q” PROTECTION
This protection system is permitted in Zone 1 and 2 locations.
There is no equivalent system recognized in the US NEC 500
electrical code. In this type of protection system the enclo-
sure or the electrical apparatus is filled with a material in a
finely divided granulated state so that, in the intended condi-
tions of service, the arc occurring within the enclosure of an
electrical apparatus will not ignite the surrounding atmos-
phere. Further, no ignition can be caused either by flame or
excessive temperature of the surfaces of the enclosure. This
protection system is used for protection of the components in
junction boxes. It is sometimes called “sand filling”.
Dust Ignitionproof. This protection technique is permitted
for equipment in Zones 20, 21, and 22 locations.
Pressurized. This protection technique is permitted for
equipment in Zones 21, and 22 locations.
Intrinsic Safety. This protection technique is permitted for
equipment in Zones 20, 21, and 22 locations.
Dusttight. This protection technique is permitted for equip-
ment in Zone 22 locations.
Nonincendive Circuit. This protection technique is permit-
ted for equipment in Zone 22 locations.
Nonincendive Equipment. This protection technique is
permitted for equipment in Zone 22 locations.
Special Protection
Some countries permit special protection systems consisting of
combinations of other systems or other special systems. UL list-
ed flashlights and lanterns for use in hazardous locations would
be an example of such a special protection system.
DEFINITIONS PERTAINING TO
NONHAZARDOUS LOCATIONS
The term NEMA enclosure is common in the US, although prod-
ucts are normally tested to a UL standard. The following are
environmental protection designations, which are specified in
addition to electrical or hazardous location requirements.
Type 1 Enclosures
Type 1 Enclosures are intended for indoor use primarily to pro-
vide a degree of protection against limited amounts of falling
dirt. This type is not specifically identified in the CSA Standard.
Type 2 Enclosures
Type 2 Enclosures are intended for indoor use primarily to pro-
vide a degree of protection against limited amounts of falling
water and dirt.
Type 3 Enclosures
Type 3 Enclosures are intended for outdoor use primarily to pro-
vide a degree of protection against rain, sleet, windblown dust;
and damage from external ice formation.
Type 3R Enclosures
Type 3R Enclosures are intended for outdoor use primarily to
provide a degree of protection against rain, sleet; and damage
from external ice formation.
Type 3S Enclosures
Type 3S Enclosures are intended for outdoor use primarily to
provide a degree of protection against rain, sleet, windblown
dust; and to provide for operation of external mechanisms when
ice laden.
Type 4 Enclosures
Type 4 Enclosures are intended for indoor or outdoor use pri-
marily to provide a degree of protection against windblown dust
and rain, splashing water, hose directed water; and damage
from external ice formation.
ENVIRONMENTAL PROTECTION
NEMA ENCLOSURE TYPES AND CSA
TYPE
X
Y
Z
EXPLANATION
Changes the area within the unit from Division 1 to nonhazardous
Changes the area within the unit from Division 1 to Division 2
Changes the area within the unit from Division 2 to nonhazardous
INTRODUCTION
HAZARDOUS LOCATION DATA H9
Type 4X Enclosures
Type 4X Enclosures are intended for indoor or outdoor use pri-
marily to provide a degree of protection against corrosion,
windblown dust and rain, splashing water, hose directed water;
and damage from external ice formation.
Type 5 Enclosures
Type 5 Enclosures are intended for indoor use primary to pro-
vide a degree of protection against settling airborne dust,
falling dirt, and dripping noncorrosive liquids.
Type 6 Enclosures
Type 6 Enclosures are intended for indoor or outdoor use pri-
marily to provide a degree of protection against hose directed
water, the entry of water during occasional temporary submer-
sion at a limited depth; and damage from external ice formation.
Type 6P Enclosures
Type 6P Enclosures are intended for indoor or outdoor use pri-
marily to provide a degree of protection against hose-directed
water, the entry of water during prolonged submersion at a limit-
ed depth; and damage from external ice formation.
Type 12 Enclosures
Type 12 Enclosures are intended for indoor use primarily to pro-
vide a degree of protection against circulating dust, falling dirt,
and dripping noncorrosive liquids.
Type 12K Enclosures
Type 12K Enclosures with knockouts are intended for indoor
use primarily to provide a degree of protection against circulat-
ing dust, falling dirt, and dripping noncorrosive liquids.
Type 13 Enclosures
Type 13 Enclosures are intended for indoor use primarily to pro-
vide a degree of protection against dust, spraying of water, oil,
and noncorrosive coolant.
DEFINITIONS PERTAINING TO HAZARDOUS
(CLASSIFIED) LOCATIONS
The following NEMA type enclosures occasionally appear on
specifications and product literature however, they are not used
by CSA. These NEMA types are specific to the US only.
Type 7 Enclosures
Type 7 Enclosures are intended for indoor use in locations clas-
sified as Class I, Groups A, B, C, or D, as defined in the NEC®.
Type 8 Enclosures
Type 8 Enclosures are for indoor or outdoor use in locations
classified as Class I, Groups A, B, C, or D, as defined in the
NEC®
Type 9 Enclosures
Type 9 Enclosures are intended for indoor use in locations clas-
sified as Class II, Groups E, F, and G, as defined in the NEC®
Type 10 Enclosures
Type 10 Enclosures are constructed to meet the applicable
requirements of the Mine Safety and Health Administration
(MSHA).
• Refer to NEMA Standards Publication No. 250 Enclosures for Electrical
Equipment (1000 Volts Maximum) or other third party certification standards
for specific requirements for product construction, testing and performance
such as Underwriters Laboratories Inc.®, Standard UL 50 “Standard for
Enclosures for Electrical Equipment”, and UL 886 “Outlet Boxes and Fittings
for use in Hazardous (Classified) Locations”.
INTRODUCTION
HAZARDOUS LOCATION DATA
H10
PROVIDES A DEGREE OF PROTECTION
AGAINST THE FOLLOWING
ENVIRONMENTAL CONDITIONS
Incidental contact with the enclosed equipment
Falling dirt
Falling liquids and light splashing
Circulating dust, lint, fibers, and flyings**
Settling airborne dust, lint, fibers, and flyings**
Hosedown and splashing water
Oil and coolant seepage
Oil and coolant spraying and splashing
Corrosive agents
Occasional temporary submersion
Occasional prolonged submersion
TYPE OF ENCLOSURE
1*
X
X
2*
X
X
X
4
X
X
X
X
X
X
4X
X
X
X
X
X
X
X
5
X
X
X
X
6
X
X
X
X
X
X
X
6P
X
X
X
X
X
X
X
12
X
X
X
X
X
X
12K
X
X
X
X
X
X
13
X
X
X
X
X
X
X
COMPARISON OF SPECIFIC APPLICATIONS OF ENCLOSURES FOR INDOOR NONHAZARDOUS LOCATIONS
* These enclosures may be ventilated. However, Type 1 may not provide protection against small particles of falling dirt when ventilation is provided in the enclosure top.
** These fibers and flyings are nonhazardous materials and are not considered as Class III type ignitable fibers or combustible flyings. For Class III type ignitable fibers
or combustible flyings see the National Electrical Code®, Article 500.
PROVIDES A DEGREE OF PROTECTION
AGAINST THE FOLLOWING
ENVIRONMENTAL CONDITIONS
Incidental contact with the enclosed equipment
Rain, snow, sleet*
Sleet**
Windblown dust
Hosedown
Corrosive agents
Occasional temporary submersion
Occasional prolonged submersion
TYPE OF ENCLOSURE
3
X
X
X
3R***
X
X
3S
X
X
X
X
4
X
X
X
X
4X
X
X
X
X
X
6
X
X
X
X
X
6P
X
X
X
X
X
X
X
COMPARISON OF SPECIFIC APPLICATIONS OF ENCLOSURES FOR OUTDOOR NONHAZARDOUS LOCATIONS
* External operating mechanisms are not required to operate when the enclosure is ice covered.
** External operating mechanisms are operable when the enclosure is ice covered.
*** These enclosures may be ventilated.
PROVIDES A DEGREE OF PROTECTION AGAINST
ATMOSPHERES TYPICALLY CONTAINING
HAZARDOUS GASES, VAPORS, AND DUSTS***
Acetylene
Hydrogen, manufactured gases
Diethyl ether, ethylene, cyclopropane
Gasoline, hexane, butane, naptha, propane, acetone
Toluene, isoprene
Metal dusts
Carbon black, coal dust, coke dust
Flour, starch, grain dust
Fibers, flyings *
Methane with or without coal dust
TYPE OF ENCLOSURE NEMA 7 & 8, CLASS I GROUPS** TYPE OF ENCLOSURE NEMA 9 & 10,
CLASS II GROUPS**
Class
I
I
I
I
II
II
II
III
MSHA
A
X
B
X
C
X
D
X
E
X
F
X
G
X
X
10
X
COMPARISON OF SPECIFIC APPLICATIONS OF ENCLOSURES FOR INDOOR HAZARDOUS (CLASSIFIED) LOCATIONS
* Due to the characteristics of the gas, vapor, or dust, a product suitable for one Class or Group may not be suitable for another Class or Group unless so
marked on the product.
** For Class III type ignitable fibers or combustible flyings refer to the National Electrical Code®Article 500.
*** For a complete listing of flammable liquids, gases, or vapors refer to NFPA 497 - 1997 (Recommended Practice for the Classification of Flammable
Liquids, Gases, or Vapors and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas and NFPA 325 - 1994 (Fire
Hazard Properties of Flammable Liquids, Gases, and Volatile Solids). Reference also NFPA 499 – 1997 Classifications of Combustible Dusts and of
Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas.
INTRODUCTION
HAZARDOUS LOCATION DATA H11
PROTECTION CLASSES OF ENCLOSURES
(IP CODE)
The IEC uses the term “Ingress Protection” to identify the
environmental protection of an enclosure.
This is defined in IEC Standard 529 and is referenced by the
CEC®. IP Codes are comparable to NEMA Enclosure Types.
The IP classification system designates, by means of a num-
ber, the degree of protection provided by an enclosure and
the electrical equipment against physical contact, foreign
bodies and water ingress.
The protection classes for electrical equipment in respect of:
I. Protection of persons against contact with live or moving
parts. (Physical contact protection)
II. Protection against ingress of solid foreign bodies. (Foreign
body protection)
III. Protection against ingress of water. (Water protection)
Structure and use of the IP Code:
I. If a code digit does not have to be given it should be
replaced with the letter “X”.
II. Additional and/or supplementary letters may be omitted
without substitute letters.
III. If more than one supplementary letter is required,
alphabetical order should be followed.
The numbering system and degree of protection follows:
The additional (optional) letter concerns protection of per-
sons and refers to information about protection against
access to dangerous parts by:
I. Back of the hand letter A
II. Finger letter B
III. Tool letter C
IV. Wire letter O
The supplemental (optional) letter concerns protection of the
equipment and provides supplementary information specially
for:
I. High voltage equipment letter H
II. Water-proofing during operation letter M
III. Water-proofing during standstill letter S
IV. Weather conditions letter W
IP CODE: NUMBERING SYSTEM
IP 5 4 C S
Code letters
First Digit 0 to 6
contact and foreign body protection
Second Digit 0 to 8
water protection
Additional letters A, B, C, O
(optional)
Supplementary letter H, M, S, W
(optional)
Non-protected
Protection against
back of hand contact.
Protection against
finger contact.
Protection against
contact from a wire
or tools.
Protection against
contact with a wire
or strip of thickness
greater than 1.0 mm
(0.039 in.).
Protection against
contact with a wire.
Protected against
contact with a wire.
Non-protected
Protected against
solid objects greater
than 50 mm (1.97 in.).
Protected against
solid objects greater
than 12 mm (0.47 in.).
Protected against
solid objects greater
the 2.5 mm (0.098 in.).
Protected against
solid objects greater
the 1.0 mm (0.039 in.).
Dust-protected pre-
vents ingress of dust
in sufficient quantity to
interfere with operation
of equipment.
Dust-tight no dust
ingress.
Non-protected
Protected against water
dripping vertically.
Protected against vertically
dripping water when tilted
up to 15‚ degrees.
Protected against spraying
water at an angle up to 60°
degrees from the vertical.
Protected from splashing
water from any direction.
Protected against water jets
from any direction.
Protected against heavy
seas or powerful jets of
water and prevents ingress
sufficient to cause harm.
Protected against the
effects of immersion
between a depth of 150 mm
to 1 meter.
Protected against submer-
sion, suitable for continuous
immersion in water under
conditions specified by the
manufacture.
DIGIT
FIRST DIGIT
PHYSICAL
PROTECTION
SECOND DIGIT
WATER PROTECTION
FOREIGN BODY
PROTECTION
0
1
2
3
4
5
6
7
8
Refer to IEC Standards Publication 529 (Classification of Degrees of
Protection Provided by Enclosures) for complete descriptions and test
requirements.
INTRODUCTION
HAZARDOUS LOCATION DATA
H12
EQUIPMENT CERTIFICATION
United States and Canada
In most cases, equipment for use in hazardous locations must
be certified to an appropriate National Standard and marked as
such by an accredited third party testing organization. Follow-up
inspection to ensure conformance is usually part of the program.
Products may carry multiple markings for multiple countries.
The specific requirements for product certification vary from
country to country. While CSA, UL and FM are similar in their
approach, subtle differences still exist. CSA, UL and FM accept
component listing of products. This means that selected prod-
ucts may be offered in modular form, which the customer may
assemble without effecting the listing.
European Countries
The countries belonging to the European Union EU, who devel-
op products based upon the standards of the European
Committee for Electrotechnical Standardization (CENELEC),
have requirements differing in many, but not all respects, from
U.S. requirements established by the NEC®and American
National Standards Institute. These CENELEC standards were
developed based on IEC 60079, and are called Euronorms.
The CENELEC standards for electrical equipment for hazardous
locations are numbered EN60079-1 through EN60079-31.
IEC Ex Scheme. The Scheme is a global conformity assess-
ment program administered by the International Electrotech-
nical Commission (IEC). This certification scheme is based
upon IEC Standards as the basis for participating countries’
certification of electrical equipment for hazardous locations.
The goal of the IEC Ex Scheme is a series of IEC Standards
Acceptable to all participating countries that will be used by
any member Certification Body to issue a certification that will
be acceptable to any member country.
MARKING
Typical North American marking
Class I, Divisions 1 & 2 Groups A, B, C, and D, T6
Class I, Zones 1 & 2 Groups IIC, IIB, IIA, T6
Class II, Divisions 1 & 2 Groups E, F, and G
Class III
NEMA 3, 4, 4X
United States “AEx” marking requires Class and Zone suitability
( Class I, Zone 1, AEx e IIC T5)
NEMA ENCLOSURE TYPE NUMBER
1
2
3
3R
3S
4 and 4X
5
6 and 6P
12 and 12K
13
IEC ENCLOSURE CLASSIFICATION
IP 23
IP 30
IP 64
IP 32
IP 54
IP 66
IP 52
IP 67
IP 55
IP 65
NEMA ENCLOSURE TYPES VS.
IEC CLASSIFICATION DESIGNATION
INTRODUCTION
HAZARDOUS LOCATION DATA H13
ATEX DIRECTIVE
This directive applies to electrical and non-electrical compo-
nents and protective systems intended for use in potentially
explosive atmospheres. Compliance with the requirements of
this new directive will become mandatory on July 1, 2003 when
the old approach directives will be repealed. Certificates of
Conformity issued under the old approach directives will remain
valid until June 30, 2003, after this date all products will need to
comply with the requirements outlined under the “New
Approach” or ATEX Directive (94/9/EC).
The ATEX Directive relates to electrical and mechanical equip-
ment and includes items such as:
• All equipment and protective systems intended for use in
potentially explosive atmospheres within the European Union
are covered and must have the CE marking along with specif-
ic type of explosion protection markings.
• Explosive atmospheres caused by the presence of gas,
vapors and mists.
• Existing, previously certified products must be re-examined to
determine compliance with the new directives.
• Mining (Group I) and surface (Group II) non-mining is
addressed. (Group I) applies to equipment intended for use
in underground parts of mines, and to those parts of surface
installations of such mines, likely to be endangered by
firedamp and/or combustible dusts. (Group II) non-mining
applies to equipment intended for use in other surface indus-
trial and offshore locations likely to be endangered by explo-
sive atmospheres.
• Equipment categories defining the required levels of protec-
tion are introduced. Category 1 covers equipment having a
very high level of protection. Category 2 covers equipment
having a high level of protection, and Category 3 covers
equipment having a normal level of protection.
• Harmonized European standards are no longer listed in the
directive. Instead, a set of electrical health and safety require-
ments is specified. CEN and CENELEC, the European stan-
dards making bodies have been charged with the responsi-
bility of preparing standards in support of these essential
health and safety requirements (EHSR’s).
• Technical requirements for equipment and protective systems
where the risk arises from combustible dusts, gases, vapors
and mist are covered by the Essential Health and Safety
Requirements.
• There is more emphasis placed upon the continued compliance
of certified products. Conformity assessment addresses both
the design and production phases. There is an option to adopt
a quality systems approach to cover the production phase for
some equipment. The quality system will be based on the ISO
9000 series of standards but augmented for this purpose.
• The requirements for surveillance are addressed in more
detail and are not therefore open to differing interpretations of
the requirements.
All manufacturers of products covered by these new directives
must prepare a declaration of conformity containing details
about the product, its intended use and how it complies with
the requirements. In most cases, this will entail the involvement
of a Notified Body in the Conformity Assessment Procedure.
FLAMMABLE GAS ALWAYS
PRESENT >1000 HRS./YEAR
FLAMMABLE GAS NORMALLY
PRESENT 10-1000 HRS./YEAR
FLAMMABLE GAS NOT NORMALLY
PRESENT <10 HRS./YEAR
U.S. — NEC 500
U.S. — NEC 505
CENELEC/IEC
ATEX
Division 1
Zone 0
Zone 0
Category 1G (Gas)
Division 1
Zone 1
Zone 1
Category 2G (Gas)
Division 2
Zone 2
Zone 2
Category 3G (Gas)
DIVISION, ZONE, CATEGORY RISK ASSESSMENT
INTRODUCTION
HAZARDOUS LOCATION DATA
H14
EXPANDED MARKINGS
U.S. (NEC 500)
Permitted Class
Permitted Division
Gas Group
Temperature Class
U. S. (NEC 505)
Permitted Class
Permitted Zone
American National
Standards Institute (ANSI)
Explosion Protected
Method of Protection
Gas Group
Temperature Class
METHOD OF PROTECTION
METHOD OF PROTECTION SYMBOL PERMITTED ZONE
IEC
Flameproof
Enclosed Break
Powder Filled
Increased Safety
Non-Sparking
Intrinsic Safety
Energy Limitation
Pressurized
Encapsulation
Oil Immersion
Restricted Breathing
Special
d
nC
q
e
nA
ia
ib
ic
nL
px
py
pz
ma
mb
o
nR
s (1)
1 & 2
2
1 & 2
1 & 2
2
0, 1 & 2
1 & 2
2
2
1 & 2
1 & 2
2
0, 1 & 2
1 & 2
1 & 2
2
PERMITTED ZONE
US (NEC 505)
1 & 2
2
1 & 2
1 & 2
2
0, 1 & 2
1 & 2
2
1 & 2
1 & 2
2
0, 1 & 2
1 & 2
1 & 2
2
ATEX CATEGORY
2
3
2
2
3
1
2
3
3
2
2
3
1
2
2
3
1
PROTECTION METHODS
(1) Must be marked suitable for Zone 0
Class I Div. 1 Groups A, B, C, D T5
Class I Zone 1 A Ex e IIC T5
IEC Ex MARKING
Explosion Protected
Method of Protection
Equipment Group
Temperature Class
ATEX MARKING
CE MARKING
Marking
Notified Body number
Explosion Protected
Equipment Group
Category
Suitable for Gas
ADDITIONAL MARKING
Explosion Protected
Method of Protection
Equipment Group
Temperature Rating
Ex e IIC T5
Ex ia IIC T4
0000 II 2 G
INTRODUCTION
CERTIFICATION MARKINGS H15
Equipment certified by the various test authorities may require
additional marking information such as the symbol or name of
the test authority, certificate number, year of issue, etc.
European countries issue certificates of conformity, and these
certificates will include special instructions on the installation,
including installation limitations.
With the advent of free trade, the Standards Council of Canada
and OSHA have accredited a number of nationally recognized
testing laboratories (NRTL) to certify equipment to each others
National Standards.
USA Multiple agencies issue product standards
• OSHA accredits testing agencies (Listing to
ANSI Standards)
• Specific, multiple or no marking may be accept-
able to, or required by regulatory agencies.
• Self-certification by a manufacturer is permitted.
Canada CSA is responsible for issuing all product standards.
• Standards Council of Canada accredits testing
agencies (Listing to CSA Standards)
• Specific marking required for approval by reg-
ulatory agencies.
CENELEC Issues Product Standards and Installation
Practices for EU Member Nations
• Testing permitted by multiple member country
agencies.
• Specific marking required for approval by reg-
ulatory agencies.
IEC EX The IEC Ex Scheme has been working on a cer-
tification mark that will be recognized and
accepted by all member countries.
UNITED STATES - THE FOLLOWING
CERTIFICATION MARKS APPLY TO THE U.S.
ONLY
If the CSA Mark appears with the “NRTL” qualifier
only, this indicates that the product is CSA certified for
the U. S. market to the applicable ANSI/UL standards.
This logo was introduced in 1999 to be consistent
in North America.
Listed means the same as certified or approved.
This means a product has been fully investigated
to a specific set of construction standards. In haz-
ardous locations, Zone type products must be
specifically “Listed” for the location.
Classified products are different than listed products.
Products carrying this mark have been evaluated for
specific properties. Although UL has a Canadian
mark, CSA has no equivalent certification process.
ULs Component Recognition Service covers the test-
ing and evaluation of component products that are
incomplete or restricted in performance capabilities.
These components will later be used in complete
products or systems approved by UL. ULs
Component Recognition Service covers components,
such as plastics, wire and printed wiring boards, that
may be used in very specific, or a broad spectrum of
end-products, or components such as motors or
power supplies. These components are not intended
for separate installation in the field, they are intended
for use as components of complete equipment sub-
mitted for investigation to UL.
Factory Mutual Approval is essentially the same as
certified or listed. This means a product has been fully
investigated to a specific set of construction stan-
dards. In hazardous locations, Factory Mutual specifi-
cally approves Zone type products for the location.
Certain manufacturers use the term “complies
with” for selected products. In the U. S., compa-
nies are permitted to “self certify” products to a
standard or set of standards, which may or may
not include ANSI standards. This means no third
party testing agency has actually investigated the
product for safety or performance. The installer
and the authorities having jurisdiction over the
electrical installations are simply accepting the
word or reputation of the manufacturer. This prac-
tice is not acceptable in Canada or EU countries.
CANADA
CANADIAN STANDARDS ASSOCIATION -
The CSA Mark may appear alone or with qualifiers.
If the CSA Mark appears alone, it means that the
product is CSA certified for the Canadian Market,
to the applicable Canadian standards.
If the CSA Mark appears with qualifiers “NRTL/C”,
It means that the product is CSA certified for the
U. S. and Canadian markets.
“Complies
With
INTRODUCTION
CERTIFICATION MARKINGS
H16
A new logo was introduced in 1999 for consistency
in North America.
Underwriters Laboratories of Canada – While it is
affiliated with UL in the U.S., ULC is a separate
agency. The ULC listing is often confused with the
C-UL mark. Underwriters Laboratories of Canada is
limited in its testing of electrical equipment there-
fore the mark is normally used in conjunction with
marking from one or more agencies. ULC deals
with all equipment related to fire alarms in Canada.
Underwriters Laboratories – There are three marks
used by UL to accommodate the Canadian market.
Products with the C-UL Listing mark have been
evaluated to Canadian safety requirements, which
may be somewhat different from U. S. safety
requirements.
The use of the C-UL Classification mark, indicates
that UL has used some or portions of the Canadian
standards to evaluate the product for specific haz-
ards or properties. CSA does not have standards
or certification procedures that allow this type of
certification. Users should check with appropriate
regulatory agency for further information.
The use of the Recognized Component mark, which
indicates that UL has used some or portions of the
Canadian standards to evaluate specific compo-
nents, is rarely seen. This mark is used specifically
on component parts that are part of a larger product
or system. These components may have restrictions
on their performance or may be incomplete in con-
struction. CSA does not have standards or certifica-
tion procedures that allow this type of certification.
Users should check with appropriate regulatory
agency for further information.
These marks indicate products meet the require-
ments of both CSA and ANSI (UL) and are suitable
for both Canada and the United States.
While these marks indicate compliance with both
U.S. and Canadian standards, construction or
certification of this type is not necessarily recog-
nized in Canada.
Others
Products approved by MET can be marked for
acceptance throughout Canada. The MET CSA
Label may indicate the applicable CSA standard
to which the product has been certified.
Intertek Testing Services – products approved by
ETL and Warnock Hersey can be marked for
acceptance throughout Canada.
EUROPE - THE FOLLOWING IS
INTENDED FOR PRODUCTS USED IN
THE EUROPEAN UNION COUNTRIES
The “Hex EX” mark identifies products which are
tested by an accredited EU member test facility to
a harmonized (CENELEC) Standard. The Ex sym-
bol is accompanied by the name of the testing
agency and a report number. All hazardous loca-
tion products used in the EU must have the Ex
mark and may also require CE or ATEX markings.
Marking to show compliance with the European
Unions (EU) approval directive. Use of the CE
mark indicates conformity to the applicable direc-
tives for a particular type of product such as
electromagnetic compatibility (EMC) or electro-
magnetic interference (EMI). This is often self
declared by the manufacturer.
INTRODUCTION
TRADEMARKS H17
CERTIFICATION POLICY
The designs of Killark products are original
and proprietary and in many instances are
covered by patents.
Killark products are designed to be installed
as governed by the National Electric Code.
The products are designed to conform with
suitable Third Party Certifier standards where
such standards exist. Most Killark standard
cataloged products are covered by third
party certification reports and inspection pro-
cedures. These certifications are a matter of
record and are indicated by the product
identification marking and the certifiers logo.
Generally, the marking is required on the
product itself, however, under certain circum-
stances, the marking may be applied to the
carton only.
In general, products are Third Party Certified
as complete assemblies, however, exceptions
do exist. One such exception would be sepa-
rate shipment of control station cover assem-
blies and the splice boxes. In some instances,
components may be covered (i.e., UL
Recognized) for use in other equipment which
will be submitted for certification of the com-
plete assembly. The nature of the agreements
with Third Party Certifiers requires that product
deviations from the originally submitted design
be resubmitted for evaluation prior to applica-
tion of the logo. It is not uncommon for re-sub-
mittals to take a substantial length of time.
Generally, Killark's standard cataloged prod-
ucts are covered by one or more of the follow-
ing Third Party certifiers: Underwriters
Laboratories Inc., Factory Mutual Research
Corporation, Canadian Standards Association,
CENELEC, BASEEFA and PTB. Products
covered are indicated by the Third Party
Certifiers logo and file number on the individ-
ual catalog pages. There may be instances
where not all products on a particular page
containing a logo are listed. When certification
information is required, consult the factory or
refer to the appropriate certifier for listings.
REGISTERED TRADEMARKS
Registered Logotype and Trademark of:
Killark
A Division of Hubbell Incorporated (Delaware)
St. Louis, MO USA
Manufacturer of Electrical Products for
Hazardous and Non-Hazardous Locations:
Fittings, Enclosures, Distribution Equipment,
Plugs and Receptacles, Controls and
Lighting Fixtures.
Is a registered trademark identifying Killark
Shelf packaging.
Electrical Conduit Fittings
CorroSAFE is a trademark identifying a pro-
tective coating used on Killark Aluminum
Electrical Conduit Fittings.
Electrical Conduit Fittings
DURALOY is a trademark identifying a Tri-Coat
protective finish used on Iron Electrical Conduit
Fittings for standard and hazardous locations.
Control Stations
DURATECH is a registered trademark
identifying Killark Non-metallic control sta-
tions for harsh and hazardous locations.
Cable Connectors
CLENCHER is a registered trademark identify-
ing Killark Cable Connectors for standard and
hazardous locations.
Cord and Cable Connectors
Z-SERIES is a trademark identifying Killark
Cord and Cable Connectors for Standard
and certain hazardous locations.
Control Stations
SEAL-X is a registered trademark identifying
Killark Factory Sealed Control Stations for
hazardous locations.
Enclosures for Hazardous & Hostile Locations
QUANTUM is a registered trademark identify-
ing Killark Electrical Junction Boxes and
Enclosures for hazardous & hostile locations.
Enclosures
PRISM is a registered trademark identifying
Killark Enclosures, Motor Controls,
Disconnect Switches and Panelboards.
Plugs and Receptacles
ACCEPTOR is a registered trademark identi-
fying Killark interchangeable Plug and
Receptacle System for hazardous locations.
Plugs & Receptacles
VersaMATE is a registered trademark identify-
ing Killark Pin & Sleeve Plugs and Receptacles
for standard and hazardous locations.
Lighting
CERTILITE is a registered trademark identify-
ing Killark Luminaires for standard and certain
hazardous locations.
Lighting
ENVIRORITE is a registered trademark iden-
tifying Killark Luminaires for standard and
hostile locations.
Lighting
HOSTILELITE is a registered trademark iden-
tifying Killark Luminaires for hazardous and
hostile locations.
Lighting
MARIGARD is a trademark identifying Killark
Stainless Steel Floodlights for Marine and
Hazardous Locations.
Lighting
LINEARLITE is a trademark identifying Killark
Fluorescent Luminaires for hostile and
hazardous locations.
LINEARLITE E is a trademark identifying
Killark Emergency Fluorescent Luminaires for
hostile and hazardous locations.
Control Stations & Panels
ConSpec is a registered trademark identify-
ing Killark Control Stations and Panels for
hazardous locations.
Terminal Enclosures
TECHNeTERM is a registered trademark
identifying Killark Increased Safety Terminal
Enclosures for hazardous locations.
EMERGENCY
Fi
FITTINGS INDEX
Section F
K-PAK®
Shelf Cartons ............................................2
Duraloy®7 Series
Aluminum or Iron Conduit Bodies ........3 - 9
Duraloy®8 Series
Iron Conduit Bodies .........................10 - 14
O Series / Duraloy®5 Series
Aluminum or Malleable Iron
Conduit Bodies .....................................15 - 19
CO & Two Series
Aluminum Conduit Bodies ..................20-22
MO/MOL/NECLB Series
Aluminum or Iron Mogul Conduit Bodies......23-26
SLB/SLBM/SOLB/MLB Series
Service Entrance.....................................27
WH Series
Conduit Hubs..........................................28
CL/CLM/TWCL Series
Pulling Elbow, Duct Seal .........................29
FB/STFB Series
Service Entrance.....................................30
F Series
Cast Device Boxes ..........................31 - 39
Covers, Accessories ........................40 - 42
FSQ/FDQ Series
Custom Drilled & Tapped Device Boxes......39
Covers, Accessories ........................40 - 42
VJ Series
Outlet Boxes ...........................................43
ENY/EY/EYS/EYD Series
Sealing Fittings ................................44 - 46
Sealing Materials ....................................48
ENY40/EYD40 Series
40% Fill Sealing Fittings ..........................47
GEB/GE Series
Aluminum and Iron Outlet Bodies.....49 - 56
GR Series
Outlet Bodies...................................57 - 58
X/XALB Series
Conduit Bodies .......................................59
STANDARD LOCATIONS
HAZARDOUS LOCATIONS
Fii
FITTINGS INDEX
Section F
JL/JAL Series
Outlet Bodies ..........................................60
GU/UN Series
Unions ....................................................61
UNF/UNY Series
Expansion Conduit Unions ......................62
PLUG/CUP/AN Series
Threaded Insert Plugs,
Rigid Conduit Nipples .............................63
KDB/KB Series
Drains and Breathers,
Flame Arrestors.......................................64
R/RE/ADUP Series
Reducing Bushings and Adapters...........65
ELBOWS ................................................66
ECF/EKJ Series
Bronze Flexible Couplings ......................67
ECFUF/EKJUF Series
Bronze Flexible Couplings with Female
Steel Unions.............................................68
EKJ Series
Stainless Steel Flexible Couplings...........69
K Series
Liquidtight Connectors.....................70 - 72
Z Series
Aluminum Cord Connectors .............73 - 75
Increased Safety Cord Connectors .....77 - 79
Z Series
Nylon Cord Connectors...........................76
Increased Safety Cord Connectors .....80 - 81
CTCA Series
Connectors for Tray Cable .....................82
CMCA Series
Metal Clad Cable Connectors .................83
CMCXA Series
Hazardous Location
Metal Clad Cable Connectors .................84
SWZ/LZN Series
Sealing Washers, Locknuts .....................85
ZHLN Series
Increased Safety Locknuts......................85
PCC/ECC/RACC Series
Conduit Clamps ......................................86
HAZARDOUS LOCATIONS
CONNECTORS - STANDARD / HAZARDOUS LOCATIONS
F
O FITTINGS
FS/FD BACK BOXES/COVERS
CATA LOG PKG
NUMBER DESCRIPTION QTY.
1FA-CP Duplex cover 50
1FT-CP Toggle cover 50
FCLA-CP Duplex cover 25
FDC-1-CP 1/2" FDC box 10
FDC-2-CP 3/4" FDC box 10
FD-1-CP 1/2" FD box 10
FD-2-CP 3/4" FD box 10
FSBC-CP Blank cover 50
FSC-1-CP 1/2" FSC box 15
FSC-2-CP 3/4" FSC box 15
FST-CP Cover 25
FS-1-CP 1/2" FS box 20
FS-2-CP 3/4" FS box 20
CATALOG PKG
NUMBER DESCRIPTION QTY.
SLB-1-CP 1/2" Service entrance LB 50
SLB-2-CP 3/4" Service entrance LB 25
SLB-3-CP 1" Service entrance LB 25
SLB FITTINGS
CATALOG PKG
NUMBER DESCRIPTION QTY.
WH-1 1/2" Conduit hub 25
WH-2 3/4" Conduit hub 25
WH-3 1" Conduit hub 25
WH WEATHERPROOF HUBS
K-PAK FITTINGS
K-PAK SHELF CARTONS
F2
K-PAK®packaging enables Killark
distributors to feature fast-moving prod-
ucts in counter display areas.
Killark’s best selling standard location
products have been repackaged into
smaller shelf packs for effective
product family presentation.
The uniformly sized (width and height
are consistent) cartons allow items to
be merchandised on a typical 48” w x
54” H x 18” gondola unit (not supplied
by Killark).
Features/Benefits
Cartons are suitable for counter
merchandising display and/or
warehouse storage.
Open-top bin box displays prod-
ucts for easy customer self-service.
All cartons are bar coded for easy
electronic identification.
Conduit bodies are packaged with
appropriate covers and gaskets.
K-PAK Carton Dimensions
Full depth cartons:
6"W x 81/2"H x 15"D
Half depth cartons:
6"W x 81/2"H x 71/2"D
Display face (width & height) same
for all cartons.
CATALOG PKG
NUMBER DESCRIPTION QTY.
OC-1CG 1/2" C w/cover & gasket 40
OC-2CG 3/4" C w/cover & gasket 25
OC-3CG 1" C w/cover & gasket 20
OC-4CG 1-1/4" C w/cover & gasket 8
OC-5CG 1-1/2" C w/cover & gasket 8
OC-6CG 2" C w/cover & gasket 3
OLB-1CG 1/2" LB w/cover & gasket 40
OLB-2CG 3/4" LB w/cover & gasket 25
OLB-3CG 1" LB w/cover & gasket 15
OLB-4CG 1-1/4" LB w/cover & gasket 8
OLB-5CG 1-1/2" LB w/cover & gasket 5
OLB-6CG 2" LB w/cover & gasket 3
OLB-7CG 2-1/2" LB w/cover & gasket 1
OLB-8CG 3" LB w/cover & gasket 1
OLB-9CG 3-1/2" LB w/cover & gasket 1
OLB-0CG 4" LB w/cover & gasket 1
OLL-1CG 1/2" LL w/cover & gasket 40
OLL-2CG 3/4" LL w/cover & gasket 25
OLL-3CG 1" LL w/cover & gasket 15
OLL-4CG 1-1/4" LL w/cover & gasket 8
OLL-5CG 1-1/2" LL w/cover & gasket 8
OLL-6CG 2" LL w/cover & gasket 3
OLR-1CG 1/2" LR w/cover & gasket 40
OLR-2CG 3/4" LR w/cover & gasket 25
OLR-3CG 1" LR w/cover & gasket 15
OLR-4CG 1-1/4" LR w/cover & gasket 8
OLR-5CG 1-1/2" LR w/cover & gasket 8
OLR-6CG 2" LR w/cover & gasket 3
OT-1CG 1/2" T w/cover & gasket 30
OT-2CG 3/4" T w/cover & gasket 25
OT-3CG 1" T w/cover & gasket 15
OT-4CG 1-1/4" T w/cover & gasket 8
OT-5CG 1-1/2" T w/cover & gasket 8
OT-6CG 2" T w/cover & gasket 2
CATALOG PKG
NUMBER DESCRIPTION QTY.
COC-1CG 1/2" C w/cover & gasket 10
COC-2CG 3/4" C w/cover & gasket 10
COC-3CG 1" C w/cover & gasket 5
COLB-1CG 1/2" LB w/cover & gasket 10
COLB-2CG 3/4" LB w/cover & gasket 10
COLB-3CG 1" LB w/cover & gasket 5
COLL-1CG 1" L w/cover & gasket 10
COLL-2CG 2" L w/cover & gasket 10
COLL-3CG 3" L w/cover & gasket 5
COLR-1CG 1/2" LR w/cover & gasket 10
COLR-2CG 3/4" LR w/cover & gasket 10
COLR-3CG 1" LR w/cover & gasket 5
COT-1CG 1/2" LR w/cover & gasket 10
COT-2CG 3/4" LR w/cover & gasket 10
COT-3CG 1" LR w/cover & gasket 5
CO FITTINGS*
FEATURES-SPECIFICATIONS
*For additional sizes see pages F20 - F22
DURALOY®7 SERIES FITTINGS
ALUMINUM OR IRON CONDUIT BODIES F3
FEATURES-SPECIFICATIONS
F
Applications
To provide access to conductors for
pulling, splicing, and maintenance.
Threaded for rigid conduit and IMC.
Features
Intermateability UL Listed and CSA
Certified interchangeability with
competitive products
Enhanced sealing capabilities
neoprene sealing gaskets provide a
NEMA 3 Seal
High-quality sealing hardware 316
stainless steel cover screws and
washers with neoprene gaskets
Suitable for wet locations
when used with gaskets
Innovative spring clip design for
installation ease and repeat usage
Smooth integral wire bushings
protects cable from damage when
wires are pulled through opening
For use with threaded rigid conduit
steel or aluminum
Ten standard hub configurations
Flat-back design for greater wiring
capacity and mounting stability
LR Type
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b),
Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
LR Type
Material/Finish
Aluminum
Copper-free aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Dimensions
LR17
LR27
LR37
LR47
LR57
LR67
LR77
LR87
LR97
LR107
LR17SA
LR27SA
LR37SA
LR47SA
LR57SA
LR67SA
LR77SA
LR87SA
LR97SA
LR107SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
4-11/16"
(119)
5-3/8"
(137)
6-5/16"
(160)
6-13/16"
(173)
7-1/4"
(184)
8-1/4"
(210)
10-15/16"
(278)
10-15/16"
(278)
13"
(330)
13"
(330)
1-7/16"
(37)
1-11/16"
(43)
1-7/8"
(48)
2-5/16"
(59)
2-9/16"
(65)
3-1/8"
(79)
4-3/8"
(111)
4-3/8"
(111)
5-3/8"
(137)
5-3/8"
(137)
2-5/16"
(59)
2-5/8"
(67)
3-1/16"
(78)
3-1/2"
(89)
3-11/16"
(94)
4-1/4"
(108)
6-3/16"
(157)
6-3/16"
(157)
7-1/4"
(184)
7-1/4"
(184)
1"
(25)
1-1/8"
(29)
1-3/8"
(35)
1-13/16"
(46)
2-1/16"
(52)
2-5/8"
(67)
3-7/8"
(98)
3-7/8"
(98)
4-3/4"
(121)
4-3/4"
(121)
3-3/16"
(81)
3-13/16"
(97)
4-1/2"
(114)
5"
(127)
5-7/16"
(138)
6-3/8"
(162)
8-3/8"
(213)
8-3/8"
(213)
10-1/4"
(260)
10-1/4"
(260)
4-1/16"
(103)
4-5/8"
(117)
5-3/8"
(137)
5-3/4"
(146)
6-1/16"
(154)
6-3/4"
(171)
8-3/4"
(222)
8-3/4"
(222)
10-5/16"
(262)
10-5/16"
(262)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-1/8"
(29)
1-1/4"
(32)
1-1/2"
(38)
2-1/8"
(54)
2-1/8"
(54)
2-5/8"
(67)
2-5/8"
(67)
4.0
7.0
11.0
19.5
26.0
48.0
131.5
131.5
238.0
238.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
LR TYPE CONDUIT BODY*
ABCDEFG
Duraloy Iron
Class 30 gray iron alloy
Superior corrosion protection
tri-coat finish of electrozinc,
chromate sealant and electrostati-
cally applied powder coating.
* For conduit body packaged with cover and gasket, add CG to the catalog number.
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
FEATURES-SPECIFICATIONS
L Type T Type
T Type
L Type
Dimensions
T17
T27
T37
T47
T57
T67
T77
T87
T97
T107
T17SA
T27SA
T37SA
T47SA
T57SA
T67SA
T77SA
T87SA
T97SA
T107SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5-11/16"
(000)
6-5/16"
(000)
7-5/8"
(194)
8"
(203)
8-7/16"
(214)
9-7/16"
(240)
12-3/4"
(324)
12-3/4"
(324)
14-7/8"
(378)
14-7/8"
(378)
1-13/16"
(46)
2-1/16"
(52)
2-1/4"
(57)
2-5/16"
(59)
2-9/16"
(65)
3-1/8"
(79)
4-3/8"
(111)
4-3/8"
(111)
5-3/8"
(137)
5-3/8"
(137)
2-1/2"
(64)
2-3/4"
(67)
3-1/4"
(83)
3-1/2"
(89)
3-11/16"
(94)
4-1/4"
(108)
6-3/16"
(157)
6-3/16"
(157)
7-1/4"
(184)
7-1/4"
(184)
6.2
9.5
11.5
20.0
27.0
50.0
134.0
134.0
238.0
238.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
T TYPE CONDUIT BODY*
ABCDEFG
L17
L27
L37
L47
L57
L67
L77
L87
L17SA
L27SA
L37SA
L47SA
L57SA
L67SA
L77SA
L87SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4-11/16"
(119)
5-3/8"
(137)
6-5/16"
(160)
6-13/16"
(173)
7-1/4"
(184)
8-1/4"
(210)
10-15/16"
(278)
10-15/16"
(278)
1-7/16"
(37)
1-11/16"
(43)
1-7/8"
(48)
2-5/16"
(59)
2-9/16"
(65)
3-1/8"
(79)
4-3/8"
(111)
4-3/8"
(111)
2-5/16"
(59)
2-5/8"
(67)
3-1/16"
(78)
3-1/2"
(89)
3-11/16"
(94)
4-1/4"
(108)
6-3/16"
(157)
6-3/16"
(157)
1"
(25)
1-1/8"
(29)
1-3/8"
(35)
1-13/16"
(46)
2-1/16"
(52)
2-5/8"
(67)
3-7/8"
(98)
3-7/8"
(98)
1"
(25)
1-1/8"
(29)
1-3/8"
(35)
1-13/16"
(46)
2-1/16"
(52)
2-5/8"
(67)
3-7/8"
(98)
3-7/8"
(98)
4-3/4"
(121)
4-3/4"
(121)
3-3/16"
(81)
3-13/16"
(97)
4-1/2"
(114)
5"
(127)
5-7/16"
(138)
6-3/8"
(162)
8-3/8"
(213)
8-3/8"
(213)
3-3/16"
(81)
3-13/16"
(97)
4-1/2"
(114)
5"
(127)
5-7/16"
(138)
6-3/8"
(162)
8-3/8"
(213)
8-3/8"
(213)
10-1/4"
(260)
10-1/4"
(260)
4-1/16"
(103)
4-5/8"
(117)
5-3/8"
(137)
5-3/4"
(146)
6-1/16"
(154)
6-3/4"
(171)
8-3/4"
(222)
8-3/4"
(222)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-1/8"
(29)
1-1/4"
(32)
1-1/2"
(38)
2-1/8"
(54)
2-1/8"
(54)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-1/8"
(29)
1-1/4"
(32)
1-1/2"
(38)
2-1/8"
(54)
2-1/8"
(54)
2-5/8"
(67)
2-5/8"
(67)
4.0
7.0
11.0
19.5
26.0
48.0
131.5
131.5
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
L TYPE1CONDUIT BODY*
ABCDEFG
See page F3 for Standard Materials & Finish
1
1L type is double faced and may be used as LL or LR. Has 2 openings, one of
which is furnished with a blank sheet cover.
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY®7 SERIES FITTINGS
ALUMINUM OR IRON CONDUIT BODIES
F4
DURALOY®7 SERIES FITTINGS
ALUMINUM OR IRON CONDUIT BODIES F5
F
FEATURES-SPECIFICATIONS
E Type
TA Type
TA Type
TB Type
TB Type
E17
E27
E37
E17SA
E27SA
E37SA
1/2"
3/4"
1"
4-11/16"
(119)
5-3/8"
(137)
6-5/16"
(160)
1-7/16"
(37)
1-11/16"
(43)
1-7/8"
(48)
1-1/2"
(38)
1-3/4"
(67)
1-15/16"
(49)
1"
(25)
1-1/8"
(29)
1-3/8"
(35)
3-3/16"
(81)
3-13/16"
(97)
4-1/2"
(114)
5/8"
(16)
3/4"
(19)
7/8"
(22)
4.0
7.0
11.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
E TYPE CONDUIT BODY*
ABCDEF G
TA17
TA27
TA37
TA47
TA57
TA67
TA17SA
TA27SA
TA37SA
TA47SA
TA57SA
TA67SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
5-11/16"
(144)
6-5/16"
(160)
7-5/8"
(194)
8"
(203)
8-7/16"
(214)
9-7/16"
(240)
2-5/8"
(67)
2-7/8"
(73)
3-3/8"
(86)
3-1/2"
(89)
3-3/4"
(95)
4-5/16"
(110)
2-1/2"
(64)
2-3/4"
(67)
3-1/4"
(000)
3-1/2"
(89)
3-11/16"
(94)
4-1/4"
(108)
1"
(25)
1-1/8"
(29)
1-3/8"
(35)
1-13/16"
(46)
2-1/16"
(52)
2-5/8"
(67)
3-3/16"
(81)
3-13/16"
(97)
4-1/2"
(114)
5"
(127)
5-7/16"
(138)
6-3/8"
(162)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-1/8"
(000)
1-1/4"
(32)
1-1/2"
(38)
6.2
9.5
15.5
20.0
27.0
50.0
HUB
SIZE
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
TA TYPE CONDUIT BODY*
ABCDEFG
TB17
TB27
TB37
TB47
TB57
TB67
TB17SA
TB27SA
TB37SA
TB47SA
TB57SA
TB67SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
5-11/16"
(144)
6-5/16"
(160)
7-5/8"
(194)
8"
(203)
8-7/16"
(214)
9-7/16"
(240)
2-5/8"
(67)
2-7/8"
(73)
3-3/8"
(86)
3-1/2"
(89)
3-3/4"
(95)
4-5/16"
(110)
1-11/16"
(43)
1-7/8"
(67)
3-3/8"
(86)
3-1/2"
(89)
3-3/4"
(95)
4-5/16"
(110)
1"
(25)
1-1/8"
(29)
1-3/8"
(35)
1-13/16"
(46)
2-1/16"
(52)
2-5/8"
(67)
3-3/16"
(81)
3-13/16"
(97)
4-1/2"
(114)
5"
(127)
5-7/16"
(138)
6-3/8"
(162)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-1/8"
(29)
1-1/4"
(32)
1-1/2"
(38)
6.2
9.5
15.5
20.0
27.0
50.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
TB TYPE CONDUIT BODY*
ABCDEFG
See page F3 for Standard Materials & Finish
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
E Type
Dimensions
KILLARK
ALUM.
DURALOY
IRON
* For conduit body packaged with cover and gasket, add CG to the catalog number.
X Type
C Type
Dimensions
X Type C Type
X17
X27
X37
X47
X57
X67
X17SA
X27SA
X37SA
X47SA
X57SA
X67SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
5-11/16"
(144)
6-5/16"
(160)
7-5/8"
(194)
8"
(203)
8-7/16"
(214)
9-7/16"
(240)
1-3/8"
(35)
2-1/16"
(52)
2-1/4"
(57)
2-5/16"
(59)
2-9/16"
(65)
3-1/8"
(79)
3-3/8"
(86)
3-9/16"
(67)
4-3/8"
(111)
4-11/16"
(000)
4-7/8"
(124)
5-7/16"
(138)
1"
(25)
1-1/8"
(29)
1-3/8"
(35)
1-13/16"
(46)
2-1/16"
(52)
2-5/8"
(67)
3-3/16"
(81)
3-13/16"
(97)
4-1/2"
(114)
5"
(127)
5-7/16"
(138)
6-3/8"
(162)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-1/8"
(29)
1-1/4"
(32)
1-1/2"
(38)
6.2
9.5
15.5
20.0
27.0
50.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
X TYPE CONDUIT BODY*
ABCDEFG
C17
C27
C37
C47
C57
C67
C77
C87
C97
C107
C17SA
C27SA
C37SA
C47SA
C57SA
C67SA
C77SA
C87SA
C97SA
C107SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5-1/2"
(140)
6-3/16"
(157)
7-7/16"
(189)
8"
(203)
8-7/16"
(214)
9-7/16"
(240)
12-3/4"
(324)
12-3/4"
(324)
14-7/8"
(378)
14-7/8"
(378)
1-7/16"
(37)
1-11/16"
(43)
1-7/8"
(48)
2-5/16"
(59)
2-9/16"
(65)
3-1/8"
(79)
4-3/8"
(111)
4-3/8"
(111)
5-3/8"
(137)
5-3/8"
(137)
1-1/2"
(38)
1-3/4"
(67)
1-15/16"
(49)
2-5/16"
(59)
2-1/2"
(64)
3-1/16"
(78)
4-3/8"
(111)
4-3/8"
(111)
5-3/8"
(137)
5-3/8"
(137)
1"
(25)
1-1/8"
(29)
1-3/8"
(35)
1-13/16"
(46)
2-1/16"
(52)
2-5/8"
(67)
3-7/8"
(98)
3-7/8"
(98)
4-3/4"
(121)
4-3/4"
(121)
3-3/16"
(81)
3-13/16"
(97)
4-1/2"
(114)
5"
(127)
5-7/16"
(138)
6-3/8"
(162)
8-3/8"
(213)
8-3/8"
(213)
10-1/4"
(260)
10-1/4"
(260)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-1/8"
(29)
1-1/4"
(32)
1-1/2"
(38)
2-1/8"
(54)
2-1/8"
(54)
2-5/8"
(67)
2-5/8"
(67)
4.0
7.0
11.0
19.5
26.0
48.0
131.5
131.5
238.0
238.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
C TYPE CONDUIT BODY*
ABCDEFG
See page F3 for Standard Materials & Finish
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
DURALOY®7 SERIES FITTINGS
ALUMINUM OR IRON CONDUIT BODIES
F6
FEATURES-SPECIFICATIONS
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY®7 SERIES FITTINGS
ALUMINUM OR IRON CONDUIT BODIES F7
FEATURES-SPECIFICATIONS
LB Type
LB17
LB27
LB37
LB47
LB57
LB67
LB77
LB87
LB97
LB107
LB17SA
LB27SA
LB37SA
LB47SA
LB57SA
LB67SA
LB77SA
LB87SA
LB97SA
LB107SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
4-11/16"
(119)
5-3/8"
(137)
6-5/16"
(160)
6-13/16"
(173)
7-1/4"
(184)
8-1/4"
(210)
10-15/16"
(278)
10-15/16"
(278)
13"
(330)
13"
(330)
2-1/4"
(57)
2-1/2"
(64)
3"
(76)
3-1/2"
(89)
3-3/4"
(95)
4-5/16"
(109)
6-3/16"
(157)
6-3/16"
(157)
7-1/4"
(184)
7-1/4"
(184)
1-1/2"
(38)
1-3/4"
(67)
1-15/16"
(49)
2-5/16"
(59)
2-1/2"
(64)
3-1/16"
(78)
4-3/8"
(111)
4-3/8"
(111)
5-3/8"
(137)
5-3/8"
(137)
1"
(25)
1-1/8"
(29)
1-3/8"
(35)
1-13/16"
(46)
2-1/16"
(52)
2-5/8"
(67)
3-7/8"
(98)
3-7/8"
(98)
4-3/4"
(121)
4-3/4"
(121)
3-3/16"
(81)
3-13/16"
(97)
4-1/2"
(114)
5"
(127)
5-7/16"
(138)
6-3/8"
(162)
8-3/8"
(213)
8-3/8"
(213)
10-1/4"
(260)
10-1/4"
(260)
4-1/16"
(103)
4-5/8"
(117)
5-3/8"
(137)
5-3/4"
(146)
6-1/16"
(154)
6-3/4"
(171)
8-3/4"
(222)
8-3/4"
(222)
10-5/16"
(262)
10-5/16"
(262)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-1/8"
(29)
1-1/4"
(32)
1-1/2"
(38)
2-1/8"
(54)
2-1/8"
(54)
2-5/8"
(67)
2-5/8"
(67)
4.0
7.0
11.0
19.5
26.0
48.0
131.5
131.5
238.0
238.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
LB TYPE CONDUIT BODY*
ABCDEFG
LL17
LL27
LL37
LL47
LL57
LL67
LL77
LL87
LL97
LL107
LL17SA
LL27SA
LL37SA
LL47SA
LL57SA
LL67SA
LL77SA
LL87SA
LL97SA
LL107SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
1-7/16"
(37)
1-11/16"
(43)
1-7/8"
(48)
2-5/16"
(59)
2-9/16"
(65)
3-1/8"
(79)
4-3/8"
(111)
4-3/8"
(111)
5-3/8"
(137)
5-3/8"
(137)
2-5/16"
(59)
2-5/8"
(67)
3-1/16"
(78)
3-1/2"
(89)
3-11/16"
(94)
4-1/4"
(108)
6-3/16"
(157)
6-3/16"
(157)
7-1/4"
(184)
7-1/4"
(184)
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
LL TYPE CONDUIT BODY*
ABCDEFG
Dimensions
LL Type
LL Type
LB Type
See page F3 for Standard Materials & Finish
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
3-3/16"
(81)
3-13/16"
(97)
4-1/2"
(114)
5"
(127)
5-7/16"
(138)
6-3/8"
(162)
8-3/8"
(213)
8-3/8"
(213)
10-1/4"
(260)
10-1/4"
(260)
4-1/16"
(103)
4-5/8"
(117)
5-3/8"
(137)
5-3/4"
(146)
6-1/16"
(154)
6-3/4"
(171)
8-3/4"
(222)
8-3/4"
(222)
10-5/16"
(262)
10-5/16"
(262)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-1/8"
(29)
1-1/4"
(32)
1-1/2"
(38)
2-1/8"
(54)
2-1/8"
(54)
2-5/8"
(67)
2-5/8"
(67)
4.0
7.0
11.0
19.5
26.0
48.0
131.5
131.5
238.0
238.0
1"
(25)
1-1/8"
(29)
1-3/8"
(35)
1-13/16"
(46)
2-1/16"
(52)
2-5/8"
(67)
3-7/8"
(98)
3-7/8"
(98)
4-3/4"
(121)
4-3/4"
(121)
4-11/16"
(119)
5-3/8"
(137)
6-5/16"
(160)
6-13/16"
(173)
7-1/4"
(184)
8-1/4"
(210)
10-15/16"
(278)
10-15/16"
(278)
13"
(330)
13"
(330)
* For conduit body packaged with cover and gasket, add CG to the catalog number.
F
DURALOY®7 SERIES FITTINGS
ALUMINUM AND STEEL COVERS AND GASKETS
F8
FEATURES-SPECIFICATIONS
Stamped Material/Finish
Aluminum
316 Stainless steel screws
Natural finish
Galvanized Steel
316 Stainless steel screws
Natural finish
STAMPED ALUMINUM AND STAMPED STEEL COVERS
170
270
370
470
570
670
870
870
970
970
170SA
270SA
370SA
470SA
570SA
670SA
870SA
870SA
970SA
970SA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
3-11/16" (94)
4-1/4" (108)
5" (127)
5-1/2" (140)
6" (152)
7" (178)
9" (229)
9" (229)
11" (279)
11" (279)
1-3/8" (35)
1-1/2" (32)
1-3/4" (44)
2-3/16" (56)
2-7/16" (62)
3" (76)
4-1/4" (108)
4-1/4" (108)
5-1/4" (133)
5-1/4" (133)
5/16" (8)
5/16" (8)
5/16" (8)
5/16" (8)
5/16" (8)
5/16" (8)
9/16" (14)
9/16" (14)
9/16" (14)
9/16" (14)
LENGTH WIDTH HEIGHT
Cast Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Duraloy Class 30 Gray Iron Alloy
Tri-coat finish of electrozinc, chro-
mate sealant, and electrostatically
applied powder coating
316 Stainless steel screws
Stamped Covers Cast Covers
HUB SIZE
STAMPED
STEEL
KILLARK
ALUMINUM
CATALOG NUMBER DIMENSIONS
CAST ALUMINUM AND CAST IRON COVERS
170C
270C
370C
470C
570C
670C
870C
870C
970C
970C
170CSA
270CSA
370CSA
470CSA
570CSA
670CSA
870CSA
870CSA
970CSA
970CSA
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
3-11/16" (94)
4-1/4" (108)
5" (127)
5-1/2" (140)
6" (152)
7" (178)
9" (229)
9" (229)
11" (279)
11" (279)
1-3/8" (35)
1-1/2" (32)
1-3/4" (44)
2-3/16" (56)
2-7/16" (62)
3" (76)
4-1/4" (108)
4-1/4" (108)
5-1/4" (133)
5-1/4" (133)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
3/8" (10)
LENGTH WIDTH HEIGHT
HUB SIZE
KILLARK
ALUMINUM
CATALOG NUMBER DIMENSIONS
Dimensions
Stamped Covers
DURALOY
IRO N
Cast Covers
DURALOY®7 SERIES FITTINGS
GASKETS F9
FEATURES-SPECIFICATIONS
F
GASK571
GASK572
GASK573
GASK574
GASK575
GASK576
GASK578
GASK578
GASK579
GASK579
Material
Open cell neoprene
Cover Gaskets
COVER GASKETS (OPEN CELL NEOPRENE)
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
3-11/16" (94)
4-1/4" (108)
5" (127)
5-1/2" (140)
6" (152)
7" (178)
9" (229)
9" (229)
11" (279)
11" (279)
1-3/8" (35)
1-1/2" (38)
1-3/4" (44)
2-3/16" (56)
2-7/16" (62)
3" (76)
4-1/4" (108)
4-1/4" (108)
5-1/4" (133)
5-1/4" (133)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
1/8" (3)
LENGTH WIDTH HEIGHT
HUB SIZE
CATALOG NUMBER DIMENSIONS
Dimensions
DURALOY®8 SERIES FITTINGS
IRON CONDUIT BODIES
F10
FEATURES-SPECIFICATIONS
C Type
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
C TYPE CONDUIT BODY*
Applications
To provide access to conductors
for pulling, splicing, and mainte-
nance. Threaded for rigid conduit
and IMC.
Features
Completely interchangeable with
competative bodies, gaskets,
and covers
Flat back design provides greater
cubic capacity for easier wire
pulling and more room for splicing
Raintight when used with gasketed
covers
Stainless steel screws on
stamped and cast covers
Smooth integral wire bushings
Material/Finish
Duraloy Class 30 Gray Iron Alloy
Tri-coat finish of electrozinc,
chromate sealant, and electrosta-
tically applied powder coating.
C Type
HUB
SIZE
CATALOG
NUMBER
VOLUME
CU. IN.
ABC
DEFG
C18
C28
C38
C448
C58
C68
C78
C88
5-5/16"
(135)
6-9/16"
(167)
7-9/16"
(192)
8-7/16"
(214)
10-3/8"
(264)
12-3/8"
(314)
15-5/8"
(397)
15-5/8"
(397)
1-15/32"
(37)
1-11/16"
(43)
1-31/32"
(50)
2-3/8"
(60)
2-25/32"
(71)
3-9/16"
(90)
4-7/16"
(113)
4-13/16"
(122)
1-15/32"
(37)
1-21/32"
(42)
1-27/32"
(47)
2-5/32"
(55)
2-25/32"
(71)
3-27/32"
(98)
5"
(127)
5"
(127)
1"
(25)
1-3/16"
(30)
1-3/8"
(35)
1-3/4"
(44)
2-3/32"
(53)
3"
(76)
4-1/4"
(108)
4-1/4"
(108)
3-9/32"
(83)
3-15/16"
(100)
4-17/32"
(115)
5-15/16"
(151)
6-1/2"
(165)
8-5/8"
(219)
10-7/8"
(276)
10-7/8"
(276)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-3/32"
(28)
1-3/8"
(35)
1-7/8"
(48)
2-1/2"
(64)
2-1/2"
(64)
5.0
8.0
12.25
23.25
42.50
105.00
200.00
217.00
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
DIMENSIONS
Dimensions
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY®8 SERIES FITTINGS
IRON CONDUIT BODIES F11
FEATURES-SPECIFICATIONS
F
LB Type LL Type
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
LB TYPE CONDUIT BODY*
LL TYPE CONDUIT BODY*
LB Type
LL Type
HUB
SIZE
CATALOG
NUMBER
VOLUME
CU. IN.
ABCDEFG
5-3/32"
(129)
5-3/4"
(146)
6-5/8"
(168)
7-1/2"
(191)
9-1/8"
(232)
11-1/8"
(283)
13-15/16"
(354)
13-15/16"
(354)
16-7/8"
(429)
16-7/8"
(429)
2-9/32"
(58)
2-1/2"
(64)
2-29/32"
(74)
3-5/16"
(84)
4-1/32"
(102)
4-13/16"
(122)
6-1/8"
(156)
6-1/2"
(165)
7-9/16"
(192)
7-13/16"
(198)
1-15/32"
(37)
1-21/32"
(42)
1-27/32"
(47)
2-5/32"
(55)
4-25/32"
(121)
4-13/16"
(122)
6-1/8"
(156)
6-1/2"
(165)
7-9/16"
(192)
7-13/16"
(198)
1"
(25)
1-3/16"
(30)
1-3/8"
(35)
1-3/4"
(44)
2-3/32"
(53)
3"
(76)
4-1/4"
(108)
4-1/4"
(108)
5-7/16"
(138)
5-7/16"
(138)
3-9/32"
(83)
3-15/16"
(100)
4-17/32"
(115)
5-15/16"
(151)
6-1/2"
(165)
8-5/8"
(219)
10-7/8"
(276)
10-7/8"
(276)
13-7/8"
(352)
13-7/8"
(352)
4-3/8"
(111)
4-29/32"
(125)
5-23/32"
(145)
6-13/32"
(163)
7-3/4"
(197)
9-3/16"
(233)
11-7/16"
(291)
11-7/16"
(291)
13-3/4"
(349)
13-3/4"
(349)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-3/32"
(28)
1-3/8"
(35)
1-7/8"
(48)
2-1/2"
(64)
2-1/2"
(64)
3-1/8"
(79)
3-1/8"
(79)
5.0
8.0
13.0
24.0
42.0
105.0
200.0
217.0
380.0
400.0
LB18
LB28
LB38
LB448
LB58
LB68
LB78
LB888
LB98
LB108
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
DIMENSIONS
HUB
SIZE
CATALOG
NUMBER
VOLUME
CU. IN.
ABCDEF G
5-3/32"
(129)
5-3/4"
(146)
6-5/8"
(168)
7-1/2"
(191)
9-1/8"
(232)
11-1/8"
(283)
13-15/16"
(354)
13-15/16"
(354)
2-9/32"
(56)
2-1/2"
(64)
2-29/32"
(74)
3-5/16"
(84)
4-1/32"
(102)
4-13/16"
(122)
6-1/8"
(156)
6-1/2"
(165)
1-15/32"
(37)
1-21/32"
(42)
1-27/32"
(47)
2-5/32"
(55)
4-25/32"
(121)
4-13/16"
(122)
6-1/8"
(156)
6-1/2"
(165)
1"
(25)
1-3/16"
(30)
1-3/8"
(35)
1-3/4"
(44)
2-3/32"
(53)
3"
(76)
4-1/4"
(108)
4-1/4"
(108)
3-9/32"
(83)
3-15/16"
(100)
4-17/32"
(115)
5-15/16"
(151)
6-1/2"
(165)
8-5/8"
(219)
10-7/8"
(276)
10-7/8"
(276)
4-3/8"
(111)
4-29/32"
(125)
5-23/32"
(145)
6-13/32"
(163)
7-3/4"
(197)
9-3/16"
(233)
11-7/16"
(291)
11-7/16"
(291)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-3/32"
(28)
1-3/8"
(35)
1-7/8"
(48)
2-1/2"
(64)
2-1/2"
(64)
5.0
8.0
13.0
24.0
42.0
105.0
200.0
217.0
LL18
LL28
LL38
LL448
LL58
LL68
LL78
LL888
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
DIMENSIONS
See page F10 for Standard Materials & Finish
Dimensions
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY®8 SERIES FITTINGS
IRON CONDUIT BODIES
F12
FEATURES-SPECIFICATIONS
LR Type T Type
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
See page F10 for Standard Materials & Finish
Dimensions
LR TYPE CONDUIT BODY*
HUB
SIZE
CATALOG
NUMBER
VOLUME
CU. IN.
ABCDEF G
5-3/32"
(129)
5-3/4"
(146)
6-5/8"
(168)
7-1/2"
(191)
9-1/8"
(232)
11-1/8"
(283)
13-15/16"
(354)
13-15/16"
(354)
1-15/16"
(49)
1-11/16"
(43)
1-31/32"
(50)
2-3/8"
(60)
2-25/32"
(71)
3-9/16"
(90)
4-7/16"
(113)
4-13/16"
(122)
2-9/32"
(58)
2-1/2"
(64)
2-29/32"
(74)
3-5/16"
(84)
4-1/32"
(102)
4-13/16"
(122)
6-1/8"
(156)
6-1/2"
(165)
1"
(52)
1-3/16"
(30)
1-3/8"
(35)
1-3/4"
(44)
2-3/32"
(53)
3"
(76)
4-1/4"
(108)
4-1/4"
(108)
3-9/32"
(83)
3-15/16"
(84)
4-17/32"
(115)
5-15/16"
(151)
6-1/2"
(165)
8-5/8"
(219)
10-7/8"
(276)
10-7/8"
(276)
4-3/8"
(111)
4-29/32"
(125)
5-23/32"
(145)
6-13/32"
(163)
7-3/4"
(199)
9-3/16"
(233)
11-7/16"
(291)
11-7/16"
(291)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-3/32"
(28)
1-3/8"
(35)
1-7/8"
(48)
2-1/2"
(64)
2-1/2"
(64)
5.0
8.0
13.0
24.0
42.0
105.0
200.0
217.0
LR18
LR28
LR38
LR448
LR58
LR68
LR78
LR888
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
DIMENSIONS
T TYPE CONDUIT BODY*
HUB
SIZE
CATALOG
NUMBER
VOLUME
CU. IN.
ABCDEFG
5-15/16"
(151)
6-9/16"
(167)
7-9/16"
(192)
8-7/16"
(214)
10-3/8"
(264)
12-3/8"
(314)
15-5/8"
(397)
15-5/8"
(397)
1-25/32"
(45)
2"
(51)
2-9/32"
(58)
2-5/8"
(67)
2-25/32"
(71)
3-9/16"
(90)
4-7/16"
(113)
4-13/16"
(122)
2-5/16"
(59)
2-1/2"
(64)
2-25/32"
(71)
3-1/8"
(79)
4-1/32"
(102)
5-1/8"
(130)
6-11/16"
(170)
6-11/16"
(170)
1"
(25)
1-3/16"
(30)
1-3/8"
(35)
1-3/4"
(44)
2-3/32"
(53)
3"
(76)
4-1/4"
(108)
4-1/4"
(108)
3-9/32"
(83)
3-15/16"
(100)
4-17/32"
(115)
5-5/16"
(135)
6-1/2"
(165)
8-5/8"
(219)
10-11/16"
(271)
10-11/16"
(271)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-3/32"
(28)
1-3/8"
(35)
1-7/8"
(48)
2-1/2"
(64)
2-1/2"
(64)
6.0
10.0
15.0
25.0
44.0
105.0
200.0
217.0
T18
T28
T38
T448
T58
T68
T78
T88
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
DIMENSIONS
LR Type
T Type
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY®8 SERIES FITTINGS
IRON CONDUIT BODIES F13
FEATURES-SPECIFICATIONS
F
TB Type X Type
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
TB Type
HUB
SIZE
CATALOG
NUMBER
VOLUME
CU. IN.
TB TYPE CONDUIT BODY*
ABCDEFG
5-15/16"
(151)
6-9/16"
(167)
7-9/16"
(192)
8-7/16"
(214)
10-3/8"
(264)
12-3/8"
(314)
2-15/16"
(75)
2-1/2"
(64)
2-25/32"
(71)
3-1/8"
(79)
4-1/32"
(102)
5-1/8"
(130)
1-15/16"
(49)
1-21/32"
(42)
1-27/32"
(47)
2-3/16"
(55)
2-25/32"
(71)
3-7/8"
(98)
1"
(25)
1-3/16"
(30)
1-3/8"
(35)
1-3/4"
(44)
2-3/32"
(53)
3"
(76)
3-9/32"
(83)
3-15/16"
(100)
4-17/32"
(115)
5-5/16"
(135)
6-1/2"
(165)
8-5/8"
(219)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-3/32"
(26)
1-3/8"
(35)
1-7/8"
(48)
6.0
10.0
15.0
25.0
44.0
105.0
TB18
TB28
TB38
TB448
TB58
TB68
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
DIMENSIONS
See page F10 for Standard Materials & Finish
Dimensions
HUB
SIZE
CATALOG
NUMBER
VOLUME
CU. IN.
X TYPE CONDUIT BODY*
ABCDEFG
5-15/16"
(151)
6-9/16"
(167)
7-9/16"
(192)
8-7/16"
(214)
10-3/8"
(264)
12-3/8"
(314)
1-25/32"
(45)
2"
(51)
2-9/32"
(58)
2-5/8"
(67)
2-25/32"
(71)
3-9/16"
(90)
3-1/8"
(79)
3-15/16"
(100)
3-23/32"
(94)
4-1/16"
(103)
5-9/32"
(134)
6-3/8"
(162)
1"
(25)
1-3/16"
(30)
1-3/8"
(35)
1-3/4"
(44)
2-3/32"
(53)
3"
(76)
3-9/32"
(83)
3-15/16"
(100)
4-17/32"
(115)
5-5/16"
(135)
6-1/2"
(165)
8-5/8"
(219)
5/8"
(16)
3/4"
(19)
7/8"
(22)
1-3/32"
(26)
1-3/8"
(35)
1-7/8"
(48)
6.0
10.0
15.0
25.0
44.0
105.0
X18
X28
X38
X448
X58
X68
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
DIMENSIONS
X Type
* For conduit body packaged with cover and gasket, add CG to the catalog number.
DURALOY®8 SERIES FITTINGS
IRON COVERS AND GASKETS
F14
FEATURES-SPECIFICATIONS
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
See page F10 for Standard Materials & Finish
OVERALL DIMENSIONS
CAST IRON COVERS
180F
280F
380F
480F
580F
680F
880F
880F
980F
980F
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH WIDTH
3/8"(10)
3/8"(10)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
HEIGHT
CATALOG
NUMBER
HUB
SIZE
4-7/32"(107)
4-13/16"(122)
5-19/32"(142)
6-9/16"(167)
7-7/8"(200)
9-3/4"(248)
12-1/4"(311)
12-1/4"(311)
15"(381)
15"(381)
1-15/32"(37)
1-21/32"(42)
1-27/32"(47)
2-3/16"(56)
2-25/32"(71)
3-7/8"(98)
5"(127)
5"(127)
6-1/4"(159)
6-1/4"(159)
OVERALL DIMENSIONS
STAMPED STEEL COVERS
180S
280S
380S
480S
580S
680S
880S
880S
980S
980S
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH WIDTH
5/16"(8)
5/16"(8)
5/16"(8)
5/16"(8)
5/16"(8)
5/16"(8)
9/16"(14)
9/16"(14)
9/16"(14)
9/16"(14)
HEIGHT
CATALOG
NUMBER
HUB
SIZE
4-7/32"(107)
4-13/16"(122)
5-19/32"(142)
6-9/16"(167)
7-7/8"(200)
9-3/4"(248)
12-1/4"(311)
12-1/4"(311)
15"(381)
15"(381)
1-15/32"(37)
1-21/32"(42)
1-27/32"(47)
2-3/16"(56)
2-25/32"(71)
3-7/8"(98)
5"(127)
5"(127)
6-1/4"(159)
6-1/4"(159)
OVERALL DIMENSIONS
COVER GASKETS
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH WIDTH
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
1/8"(3)
HEIGHT
CATALOG
NUMBER
HUB
SIZE
4-7/32"(107)
4-13/16"(122)
5-19/32"(142)
6-9/16"(167)
7-7/8"(200)
9-3/4"(248)
12-1/4"(311)
12-1/4"(311)
15"(381)
15"(381)
1-15/32"(37)
1-21/32"(42)
1-27/32"(47)
2-3/16"(56)
2-25/32"(71)
3-7/8"(98)
5"(127)
5"(127)
6-1/4"(159)
6-1/4"(159)
GASK851N
GASK852N
GASK853N
GASK854N
GASK805N
GASK806N
GASK808N
GASK808N
GASK809N
GASK809N
Cover Gaskets (Neoprene)
Stamped Steel CoversCast Covers
Cast Material/Finish
Duraloy Class 30 Gray Iron Alloy
Tri-coat finish of electrozinc, chro-
mate sealant, and electrostatically
applied powder coating
300 Series stainless steel screws
Galvanized Steel
Natural finish
300 Series stainless steel screws
Material/Finish
Neoprene. Compression molded.
O SERIES / DURALOY®5 S E R I E S FITTINGS
ALUMINUM OR MALLEABLE IRON CONDUIT BODIES F15
FEATURES-SPECIFICATIONS
F
E TypeC Type
Applications
To provide access to conductors for
pulling, splicing, and maintenance.
Threaded for rigid conduit and IMC.
Features
Tapered threaded hubs (NPT)
Raintight when used with gasketed
covers
Malleable iron suitable for use in
concrete
Interchangeable with competitive
products
Stainless steel screws on stamped
and cast covers
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Duraloy Malleable Iron
Tri-coat finish of electrozinc, chro-
mate sealant, and electrostatically
applied powder coating.
C Type
Dimensions
E Type
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5-3/16"
(132)
6-1/8"
(156)
7-1/8"
(181)
9-1/8"
(232)
9-1/4"
(235)
11-7/8"
(302)
15-1/8"
(384)
15-1/8"
(384)
18-3/8"
(467)
18-3/8"
(467)
1-3/8"
(35)
1-5/8"
(41)
2"
(51)
2-5/8"
(67)
2-3/4"
(70)
3-1/2"
(89)
4"
(102)
4-3/4"
(121)
5-1/2"
(140)
5-5/8"
(143)
1-3/8"
(35)
1-5/8"
(67)
1-7/8"
(48)
2-5/8"
(67)
2-5/8"
(67)
3-1/8"
(79)
4-3/8"
(111)
4-3/8"
(111)
5-1/2"
(140)
5-1/2"
(140)
1"
(25)
1-7/32"
(31)
1-15/32"
(37)
2"
(51)
2"
(51)
2-9/16"
(65)
3-11/16"
(94)
3-11/16"
(94)
4-7/8"
(124)
4-7/8"
(124)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
6"
(152)
6"
(152)
8-1/16"
(205)
10-5/8"
(270)
10-5/8"
(270)
13-1/8"
(333)
13-1/8"
(333)
5/8"
(16)
3/4"
(19)
15/16"
(24)
1-3/16"
(30)
1-3/8"
(32)
1-5/8"
(38)
1-13/16"
(54)
2-3/16"
(54)
2-1/2"
(67)
2-3/4"
(67)
4.0
7.0
12.0
32.0
36.0
70.0
153.0
181.0
290.0
320.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
C TYPE CONDUIT BODY*
ABCD EFG
OC-1M
OC-2M
OC-3M
OC-4M
OC-5M
OC-6M
OC-7M
OC-8M
OC-9M
OC-0M
OC-1
OC-2
OC-3
OC-4
OC-5
OC-6
OC-7
OC-8
OC-9
OC-0
OE-1M
OE-2M
OE-3M
OE-1
OE-2
OE-3
1/2"
3/4"
1"
4-5/8"
(117)
5-3/8"
(41)
6-1/4"
(159)
1-3/8"
(35)
1-5/8"
(137)
2"
(51)
1-3/8"
(35)
1-5/8"
(41)
1-7/8"
(48)
1"
(25)
1-7/32"
(29)
1-15/32"
(35)
3-9/32"
(83)
3-15/16"
(100)
4-17/32"
(115)
5/8"
(16)
3/4"
(19)
7/8"
(22)
4.0
7.0
12.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
E TYPE CONDUIT BODY*
ABCDEFG
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
* For conduit body packaged with cover and gasket, add CG to the catalog number.
O SERIES / DURALOY®5 SERIES FITTINGS
ALUMINUM OR MALLEABLE IRON CONDUIT BODIES
F16
FEATURES-SPECIFICATIONS
Dimensions
LB Type
LB Type
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
4-17/32"
(115)
5-3/4"
(146)
6-5/8"
(168)
7-1/2"
(191)
9-1/8"
(232)
10"
(254)
13-15/16"
(354)
13-15/16"
(354)
16-7/8"
(429)
16-7/8"
(429)
2-9/32"
(83)
2-1/2"
(64)
2-29/32"
(74)
3-3/16"
(81)
4"
(102)
4-13/16"
(122)
6-1/8"
(156)
6-1/2"
(165)
7-9/16"
(192)
7-13/16"
(198)
1-3/8"
(35)
1-5/8"
(41)
1-7/8"
(48)
2-5/8"
(67)
2-5/8"
(67)
3-1/8"
(79)
4-3/8"
(111)
4-3/8"
(111)
5-1/2"
(140)
5-1/2"
(140)
1"
(25)
1-7/32"
(31)
1-15/32"
(37)
2"
(51)
2"
(51)
2-9/16"
(65)
3-11/16"
(94)
3-11/16"
(94)
4-7/8"
(124)
4-7/8"
(124)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
6"
(152)
6"
(152)
8-1/16"
(205)
10-5/8"
(270)
10-5/8"
(270)
13-1/8"
(333)
13-1/8"
(333)
5/8"
(16)
3/4"
(19)
15/16"
(24)
1-3/16"
(30)
1-3/8"
(32)
1-5/8"
(38)
2-1/2"
(64)
2-3/16"
(54)
2-1/2"
(67)
2-3/4"
(70)
4.0
7.0
12.0
28.8
36.0
70.0
142.0
173.0
292.0
324.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
LB TYPE CONDUIT BODY*
ABCDEFG
OLB-1M
OLB-2M
OLB-3M
OLB-4M
OLB-5M
OLB-6M
OLB-7M
OLB-8M
OLB-9M
OLB-0M
OLB-1
OLB-2
OLB-3
OLB-4
OLB-5
OLB-6
OLB-7
OLB-8
OLB-9
OLB-0
See page F15 for Standard Materials & Finish
4-3/8"
(111)
4-29/32"
(125)
5-23/32"
(145)
6-13/32"
(162)
17-3/4"
(451)
8-5/32"
(207)
11-7/16"
(291)
11-7/16"
(291)
13-3/4"
(349)
13-3/4"
(349)
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
1"
(25)
1-7/32"
(31)
1-15/32"
(37)
2"
(51)
2"
(51)
2-9/16"
(65)
3-11/16"
(94)
3-11/16"
(94)
4-7/8"
(124)
4-7/8"
(124)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
6"
(152)
6"
(152)
8-1/16"
(205)
10-5/8"
(270)
10-5/8"
(270)
13-1/8"
(333)
13-1/8"
(333)
5/8"
(16)
3/4"
(19)
15/16"
(24)
1-3/16"
(30)
1-3/8"
(32)
1-5/8"
(38)
1-13/16"
(46)
2-3/16"
(54)
2-1/2"
(67)
2-3/4"
(70)
4.0
7.0
12.0
32.0
36.0
70.0
142.0
173.0
292.0
324.0
LL TYPE CONDUIT BODY*
LL Type
LL Type
OLL-1M
OLL-2M
OLL-3M
OLL-4M
OLL-5M
OLL-6M
OLL-7M
OLL-8M
OLL-9M
OLL-0M
OLL-1
OLL-2
OLL-3
OLL-4
OLL-5
OLL-6
OLL-7
OLL-8
OLL-9
OLL-0
4-5/8"
(117)
5-3/8"
(137)
6-1/4"
(159)
8-1/8"
(206)
8-1/8"
(206)
10-9/16"
(268)
13-11/16"
(348)
13-11/16"
(348)
16-1/2"
(419)
16-1/2"
(419)
1-3/8"
(35)
1-5/8"
(41)
2"
(51)
2-5/8"
(67)
2-3/4"
(70)
3-1/2"
(89)
4"
(102)
4-3/4"
(121)
5-1/2"
(140)
5-5/8"
(143)
2"
(51)
2-3/16"
(56)
2-9/16"
(65)
3-1/2"
(89)
3-1/2"
(89)
4-3/16"
(106)
5-3/4"
(146)
5-3/4"
(146)
7-1/8"
(181)
7-1/8"
(181)
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
* For conduit body packaged with cover and gasket, add CG to the catalog number.
O SERIES / DURALOY®5 S E R I E S FITTINGS
ALUMINUM OR MALLEABLE IRON CONDUIT BODIES F17
FEATURES-SPECIFICATIONS
F
See page F15 for Standard Materials & Finish
LR Type T Type
LR Type
T Type
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
4-5/8"
(117)
5-3/8"
(137)
6-1/4"
(159)
8-1/8"
(206)
8-1/8"
(206)
10-9/16"
(268)
13-11/16"
(348)
13-11/16"
(348)
16-1/2"
(419)
16-1/2"
(419)
1-3/8"
(35)
1-5/8"
(41)
2"
(51)
2-5/8"
(67)
2-3/4"
(70)
3-1/2"
(89)
4"
(102)
4-3/4"
(121)
5-1/2"
(140)
5-5/8"
(143)
2"
(35)
2-3/16"
(67)
2-9/16"
(65)
3-1/2"
(89)
3-1/2"
(89)
4-3/16"
(106)
5-3/4"
(146)
5-3/4"
(146)
7-1/8"
(181)
7-1/8"
(181)
1"
(25)
1-7/32"
(31)
1-15/32"
(37)
2"
(51)
2"
(51)
2-9/16"
(65)
3-11/16"
(93)
3-11/16"
(93)
4-7/8"
(124)
4-7/8"
(124)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
6"
(152)
6"
(152)
8-1/16"
(205)
10-5/8"
(270)
10-5/8"
(270)
13-1/8"
(333)
13-1/8"
(333)
4-3/8"
(111)
4-29/32"
(125)
5-23/32"
(145)
6-13/32"
(162)
17-3/4"
(451)
9-5/32"
(233)
11-7/16"
(291)
11-7/16"
(291)
13-3/4"
(349)
13-3/4"
(349)
5/8"
(16)
3/4"
(19)
15/16"
(24)
1-3/16"
(30)
1-3/8"
(32)
1-5/8"
(38)
1-13/16"
(54)
2-3/16"
(54)
2-1/2"
(67)
2-3/4"
(67)
4.0
7.0
12.0
32.0
31.0
70.0
142.0
173.0
292.0
324.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
LR TYPE CONDUIT BODY*
ABCD EFG
Dimensions
OLR-1M
OLR-2M
OLR-3M
OLR-4M
OLR-5M
OLR-6M
OLR-7M
OLR-8M
OLR-9M
OLR-0M
OLR-1
OLR-2
OLR-3
OLR-4
OLR-5
OLR-6
OLR-7
OLR-8
OLR-9
OLR-0
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5-3/8"
(137)
6-1/16"
(154)
7-1/8"
(181)
9-3/16"
(233)
9-3/16"
(233)
11-5/8"
(295)
15-1/8"
(384)
15-1/8"
(384)
18-1/8"
(460)
18-1/8"
(460)
1-3/8"
(35)
1-5/8"
(41)
2"
(51)
2-5/8"
(67)
2-3/4"
(70)
3-1/2"
(89)
4"
(102)
4-3/4"
(121)
5-1/2"
(140)
5-5/8"
(143)
2"
(35)
2-3/16"
(67)
2-9/16"
(65)
3-1/2"
(89)
3-1/2"
(89)
4-3/16"
(106)
5-3/4"
(146)
5-3/4"
(146)
7-1/8"
(181)
7-1/8"
(181)
1"
(25)
1-7/32"
(31)
1-15/32"
(37)
2"
(51)
2"
(51)
2-9/16"
(65)
3-11/16"
(94)
3-11/16"
(94)
4-7/8"
(124)
4-7/8"
(124)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
6"
(152)
6"
(152)
8-1/16"
(205)
10-5/8"
(270)
10-5/8"
(270)
13-1/8"
(333)
13-1/8"
(333)
5/8"
(16)
3/4"
(19)
15/16"
(24)
1-3/16"
(30)
1-3/8"
(32)
1-5/8"
(38)
1-13/16"
(54)
2-3/16"
(54)
2-1/2"
(67)
2-3/4"
(67)
4.0
7.0
12.0
32.0
33.0
70.0
142.0
173.0
292.0
324.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER
DIMENSIONS VOLUME
CU. IN.
T TYPE CONDUIT BODY*
ABCDEFG
OT-1M
OT-2M
OT-3M
OT-4M
OT-5M
OT-6M
OT-7M
OT-8M
OT-9M
OT-0M
OT-1
OT-2
OT-3
OT-4
OT-5
OT-6
OT-7
OT-8
OT-9
OT-0
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
* For conduit body packaged with cover and gasket, add CG to the catalog number.
O SERIES / DURALOY®5 SERIES FITTINGS
ALUMINUM OR MALLEABLE IRON CONDUIT BODIES
F18
FEATURES-SPECIFICATIONS
See page F15 for Standard Materials & Finish
Dimensions
X Type
TB Type
TA Type
TB Type
X Type
OTA-1M
OTA-2M
OTA-3M
OTA-1
OTA-2
1/2"
3/4"
1"
2"
(51)
2-3/16"
(56)
2-9/16"
(65)
5-3/8"
(137)
6-1/16"
(154)
7-1/8"
(181)
1"
(25)
1-7/32"
(29)
1-15/32"
(35)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
5/8"
(16)
3/4"
(19)
15/16"
(24)
4.0
7.0
12.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
TA TYPE CONDUIT BODY*
ABCDEFG
2-1/8"
(54)
2-15/16"
(75)
2-11/16"
(68)
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
5-3/8"
(137)
6-1/16"
(160)
7-1/8"
(181)
9-3/16"
(233)
9-3/16"
(233)
11-5/8"
(295)
2-1/8"
(54)
2-5/16"
(59)
2-11/16"
(68)
3-9/16"
(90)
3-3/4"
(92)
4-5/8"
(117)
1-5/16"
(33)
1-9/16"
(40)
1-13/16"
(46)
2-1/2"
(64)
2-1/2"
(64)
3-1/8"
(79)
1"
(25)
1-7/32"
(31)
1-15/32"
(37)
2"
(51)
2"
(51)
2-9/16"
(65)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
6"
(152)
6"
(152)
8-1/16"
(205)
5/8"
(16)
3/4"
(19)
15/16"
(24)
1-3/16"
(30)
1-3/8"
(35)
1-5/8"
(41)
4.0
7.0
12.0
32.0
36.0
70.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
TB TYPE CONDUIT BODY*
ABCDEFG
OTB-1M
OTB-2M
OTB-3M
OTB-4M
OTB-5M
OTB-6M
OTB-1
OTB-2
OTB-3
OTB-4
OTB-5
OTB-6
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
5-3/8"
(137)
6-1/16"
(160)
7-1/8"
(181)
9-3/16"
(233)
9-3/16"
(233)
11-5/8"
(295)
1-3/4"
(44)
2"
(51)
2-1/4"
(57)
2-9/16"
(65)
2-3/4"
(70)
3-3/8"
(85)
1-11/16"
(43)
2-7/8"
(73)
3-3/8"
(86)
4-1/2"
(114)
4-1/2"
(114)
5-1/4"
(133)
1"
(25)
1-7/32"
(31)
1-15/32"
(37)
2"
(51)
2"
(51)
2-9/16"
(65)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
6"
(152)
6"
(152)
8-1/16"
(205)
5/8"
(16)
3/4"
(19)
15/16"
(24)
1-3/16"
(30)
1-3/8"
(35)
1-5/8"
(41)
4.0
7.0
12.0
32.0
36.0
70.0
HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER DIMENSIONS VOLUME
CU. IN.
X TYPE CONDUIT BODY*
ABCDEF
G
OX-1M
OX-2M
OX-3M
OX-4M
OX-5M
OX-6M
OX-1
OX-2
OX-3
OX-4
OX-5
OX-6
Suitable for wet locations when
used with gasketed covers.
Federal Specification
W-C-586D/A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
TA Type
* For conduit body packaged with cover and gasket, add CG to the catalog number.
O SERIES / DURALOY®5 S E R I E S FITTINGS
COVERS AND GASKETS F19
FEATURES-SPECIFICATIONS
F
Suitable for wet locations when
used with gasketed covers.
Federal Specification W-C-586D /
A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed File No. E3397
Certified File No. LR11852
ALUMINUM AND STEEL STAMPED COVERS
Fiber Gasket
DIMENSIONS
CAST IRON COVERS
OL-10CM
OL-20CM
OL-30CM
OL-45CM
OL-45CM
OL-60CM
OL-78CM
OL-78CM
OL-90CM
OL-90CM
3-15/16"(100)
4-5/8"(117)
5-3/8"(137)
7-3/16"(183)
7-3/16"(183)
9-1/2"(241)
12-1/4"(311)
12-1/4"(311)
14-7/8"(378)
14-7/8"(378)
3-15/16"(100)
4-5/8"(117)
5-3/8"(137)
7-3/16"(183)
7-3/16"(183)
9-1/2"(241)
12-1/4"(311)
12-1/4"(311)
14-7/8"(378)
14-7/8"(378)
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH
1-3/8"(35)
1-5/8"(41)
1-7/8"(48)
2-5/8"(67)
2-5/8"(67)
3-1/8"(79)
4-3/8"(111)
4-3/8"(111)
5-1/2"(140)
5-1/2"(140)
WIDTH
3/8"(10)
3/8"(10)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
1-3/8"(35)
1-5/8"(41)
1-7/8"(48)
2-5/8"(67)
2-5/8"(67)
3-1/8"(79)
4-3/8"(111)
4-3/8"(111)
5-1/2"(140)
5-1/2"(140)
HEIGHT
DIMENSIONS
LENGTH WIDTH HEIGHT
FIBER
HUB
SIZE
OLK-1VG
OLK-2VG
OLK-3VG
OL-45-VG
OL-45-VG
OL-6-VG
OL-78-VG
OL-78-VG
OL-90-VG
OL-90-VG
CATALOG NUMBER
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
Cast Material/Finish
Duraloy Malleable Iron
Tri-coat finish of electrozinc, chro-
mate sealant, and electrostatically
applied powder coating
300 Series stainless steel screws
Stamped Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Natural finish
300 Series stainless steel screws
Galvanized Steel
Natural finish
300 Series stainless steel screws
Material/Finish
Neoprene or fiber
CATALOG
NUMBER
HUB
SIZE
HUB
SIZE
GASKETS
OLK-1RG
OLK-2RG
OLK-3RG
OL-45-RG
OL-45-RG
OL-6-RG
OL-78-RG
OL-78-RG
OL-90-RG
OL-90-RG
3/8"(10)
3/8"(10)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
Cast Iron Covers
NEOPRENE
Neoprene Gasket
CATALOG NUMBER
KILLARK
ALUMINUM STEEL
Aluminum and Steel Stamped Covers
OL-10M
OL-20M
OL-30M
OL-45M
OL-45M
OL-60M
OL-78M
OL-78M
OL-90M
OL-90M
OL-10
OL-20
OL-30
OL-450
OL-450
OL-60
OL-780
OL-780
OL-900
OL-900
C O & T W O S E R I E S FITTINGS
ALUMINUM CONDUIT BODIES
FEATURES-SPECIFICATIONS
Dimensions
Listed File No. E3397
Certified File No. LR11852
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5-3/8"
(137)
6-1/8"
(156)
7-1/8"
(181)
9-1/8"
(232)
9-1/4"
(235)
11-7/8"
(302)
15-1/8"
(384)
15-1/8"
(384)
18-3/8"
(467)
18-3/8"
(467)
1-3/8"
(35)
1-5/8"
(41)
2"
(51)
2-5/8"
(67)
2-3/4"
(70)
3-1/2"
(89)
4"
(102)
4-3/4"
(121)
5-1/2"
(140)
5-5/8"
(143)
1-3/8"
(35)
1-5/8"
(67)
1-7/8"
(48)
2-5/8"
(67)
2-5/8"
(67)
3-1/8"
(79)
4-3/8"
(111)
4-3/8"
(111)
5-1/2"
(140)
5-1/2"
(140)
1"
(25)
1-7/32"
(31)
1-15/32"
(37)
2"
(51)
2"
(51)
2-9/16"
(65)
3-11/16"
(94)
3-11/16"
(94)
4-7/8"
(124)
4-7/8"
(124)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
6"
(152)
6"
(152)
8-1/16"
(205)
10-5/8"
(270)
10-5/8"
(270)
13-1/8"
(333)
13-1/8"
(333)
5/8"
(16)
3/4"
(19)
15/16"
(24)
1-3/16"
(30)
1-3/8"
(32)
1-5/8"
(38)
1-13/16"
(54)
2-3/16"
(54)
2-1/2"
(67)
2-3/4"
(67)
4.0
7.0
12.0
32.0
36.0
70.0
153.0
181.0
290.0
320.0
HUB
SIZE
CATALOG
NUMBER
DIMENSIONS VOLUME
CU. IN.
C TYPE CONDUIT BODY
ABCDEFG
COC-1CG
COC-2CG
COC-3CG
COC-4CG
COC-5CG
COC-6CG
TWOC-7CG
TWOC-8CG
TWOC-9CG
TWOC-0CG
C Type - COC-4,5,6 LB Type - COLB-4,5,6
C Type
LB Type - COLB-1,2,3
Applications
To provide access to conductors for
pulling, splicing, maintenance, and for
future changes or upgrades. Combination
bodies (1/2”- 2”) for use with EMT or
Rigid/IMC conduit. Sizes 2-1/2 and larger
for use with EMT only (not threaded).
Features
Combination bodies have threaded and
set screw hubs
Pre-packaged with body, cover and
gasket.
Covers furnished with stainless steel
screws
Material/Finish
Conduit Bodies - Die cast, copper-free
aluminum (less than 4/10 of 1%) with
electrostatically applied powder coating.
Covers - Stamped Aluminum/Natural Finish
Gaskets - Neoprene
C
O
M
B
O
E
M
T
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
4-17/32"
(115)
5-3/4"
(146)
6-5/8"
(168)
7-1/2"
(191)
9-1/8"
(232)
10"
(254)
13-15/16"
(354)
13-15/16"
(354)
16-7/8"
(429)
16-7/8"
(429)
2-9/32"
(83)
2-1/2"
(64)
2-29/32"
(74)
3-3/16"
(81)
4"
(102)
4-13/16"
(122)
6-1/8"
(156)
6-1/2"
(165)
7-9/16"
(192)
7-13/16"
(198)
1-3/8"
(35)
1-5/8"
(41)
1-7/8"
(48)
2-5/8"
(67)
2-5/8"
(67)
3-1/8"
(79)
4-3/8"
(111)
4-3/8"
(111)
5-1/2"
(140)
5-1/2"
(140)
1"
(25)
1-7/32"
(31)
1-15/32"
(37)
2"
(51)
2"
(51)
2-9/16"
(65)
3-11/16"
(94)
3-11/16"
(94)
4-7/8"
(124)
4-7/8"
(124)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
6"
(152)
6"
(152)
8-1/16"
(205)
10-5/8"
(270)
10-5/8"
(270)
13-1/8"
(333)
13-1/8"
(333)
4-3/8"
(111)
4-29/32"
(125)
5-23/32"
(145)
6-13/32"
(162)
17-3/4"
(451)
8-5/32"
(207)
11-7/16"
(291)
11-7/16"
(291)
13-3/4"
(349)
13-3/4"
(349)
5/8"
(16)
3/4"
(19)
15/16"
(24)
1-3/16"
(30)
1-3/8"
(32)
1-5/8"
(38)
2-1/2"
(64)
2-3/16"
(54)
2-1/2"
(67)
2-3/4"
(70)
4.0
7.0
12.0
28.8
36.0
70.0
142.0
173.0
292.0
324.0
HUB
SIZE
CATALOG
NUMBER
DIMENSIONS VOLUME
CU. IN.
LB TYPE CONDUIT BODY
ABCDEFG
COLB-1CG
COLB-2CG
COLB-3CG
COLB-4CG
COLB-5CG
COLB-6CG
TWOLB-7CG
TWOLB-8CG
TWOLB-9CG
TWOLB-0CG
C
O
M
B
O
E
M
T
LB Type
Unit Packaging
Body/Cover/Gasket
C Type - COC-1,2,3
F20
C O & T W O S E R I E S FITTINGS
ALUMINUM CONDUIT BODIES F21
FEATURES-SPECIFICATIONS
F
Listed File No. E3397
Certified File No. LR11852
LR Type - COLR-4,5,6
See page F20 for Applications, Features
and Standard Materials & Finish
LL Type - COL-1,2,3 LR Type - COLR-1,2,3
LL Type - COL-4,5,6
Dimensions
LL Type
LR Type
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
4-5/8"
(117)
5-3/8"
(137)
6-1/4"
(159)
8-1/8"
(206)
8-1/8"
(206)
10-9/16"
(268)
13-11/16"
(348)
13-11/16"
(348)
16-1/2"
(419)
16-1/2"
(419)
1-3/8"
(35)
1-5/8"
(41)
2"
(51)
2-5/8"
(67)
2-3/4"
(70)
3-1/2"
(89)
4"
(102)
4-3/4"
(121)
5-1/2"
(140)
5-5/8"
(143)
2"
(35)
2-3/16"
(67)
2-9/16"
(65)
3-1/2"
(89)
3-1/2"
(89)
4-3/16"
(106)
5-3/4"
(146)
5-3/4"
(146)
7-1/8"
(181)
7-1/8"
(181)
1"
(25)
1-7/32"
(31)
1-15/32"
(37)
2"
(51)
2"
(51)
2-9/16"
(65)
3-11/16"
(93)
3-11/16"
(93)
4-7/8"
(124)
4-7/8"
(124)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
6"
(152)
6"
(152)
8-1/16"
(205)
10-5/8"
(270)
10-5/8"
(270)
13-1/8"
(333)
13-1/8"
(333)
4-3/8"
(111)
4-29/32"
(125)
5-23/32"
(145)
6-13/32"
(162)
17-3/4"
(451)
9-5/32"
(233)
11-7/16"
(291)
11-7/16"
(291)
13-3/4"
(349)
13-3/4"
(349)
5/8"
(16)
3/4"
(19)
15/16"
(24)
1-3/16"
(30)
1-3/8"
(32)
1-5/8"
(38)
1-13/16"
(54)
2-3/16"
(54)
2-1/2"
(67)
2-3/4"
(67))
4.0
7.0
12.0
32.0
31.0
70.0
142.0
173.0
292.0
324.0
HUB
SIZE
CATALOG
NUMBER
DIMENSIONS VOLUME
CU. IN.
LR TYPE CONDUIT BODY
ABCDEFG
COLR-1CG
COLR-2CG
COLR-3CG
COLR-4CG
COLR-5CG
COLR-6CG
TWOLR-7CG
TWOLR-8CG
TWOLR-9CG
TWOLR-0CG
C
O
M
B
O
E
M
T
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
4-5/8"
(117)
5-3/8"
(137)
6-1/4"
(159)
8-1/8"
(206)
8-1/8"
(206)
10-9/16"
(268)
13-11/16"
(348)
13-11/16"
(348)
16-1/2"
(419)
16-1/2"
(419)
1-3/8"
(35)
1-5/8"
(41)
2"
(51)
2-5/8"
(67)
2-3/4"
(70)
3-1/2"
(89)
4"
(102)
4-3/4"
(121)
5-1/2"
(140)
5-5/8"
(143)
2"
(51)
2-3/16"
(56)
2-9/16"
(65)
3-1/2"
(89)
3-1/2"
(89)
4-3/16"
(106)
5-3/4"
(146)
5-3/4"
(146)
7-1/8"
(181)
7-1/8"
(181)
1"
(25)
1-7/32"
(31)
1-15/32"
(37)
2"
(51)
2"
(51)
2-9/16"
(65)
3-11/16"
(94)
3-11/16"
(94)
4-7/8"
(124)
4-7/8"
(124)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
6"
(152)
6"
(152)
8-1/16"
(205)
10-5/8"
(270)
10-5/8"
(270)
13-1/8"
(333)
13-1/8"
(333)
5/8"
(16)
3/4"
(19)
15/16"
(24)
1-3/16"
(30)
1-3/8"
(32)
1-5/8"
(38)
1-13/16"
(46)
2-3/16"
(54)
2-1/2"
(67)
2-3/4"
(67)
4.0
7.0
12.0
32.0
31.0
70.0
142.0
173.0
292.0
324.0
HUB
SIZE
CATALOG
NUMBER
DIMENSIONS VOLUME
CU. IN.
LL TYPE CONDUIT BODY
ABCDEFG
COLL-1CG
COLL-2CG
COLL-3CG
COLL-4CG
COLL-5CG
COLL-6CG
TWOLL-7CG
TWOLL-8CG
TWOLL-9CG
TWOLL-0CG
C
O
M
B
O
E
M
T
Unit Packaging
Body/Cover/Gasket
C O & T W O S E R I E S FITTINGS
ALUMINUM CONDUIT BODIES
F22
FEATURES-SPECIFICATIONS
Unit Packaging
Body/Cover/Gasket
LISTED - FILE E3397
CERTIFIED - FILE LR11852
See page F20 for Applications, Features
and Standard Materials & Finish
Dimensions
T Type
ALUMINUM STAMPED COVER
T Type - COT-1,2,3 NEOPRENE GASKET
T Type - COT-4,5,6
HUB
SIZE
CATALOG
NUMBER
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
NEOPRENE REPLACEMENT GASKETS
OLK-1RG
OLK-2RG
OLK-3RG
OL-45-RG
OL-45-RG
OL-6-RG
OL-78-RG
OL-78-RG
OL-90-RG
OL-90-RG
DIMENSIONS
ALUMINUM REPLACEMENT COVERS
OL-10
OL-20
OL-30
OL-450
OL-450
OL-60
OL-780
OL-780
OL-900
OL-900
3-15/16"(100)
4-5/8"(117)
5-3/8"(137)
7-3/16"(183)
7-3/16"(183)
9-1/2"(241)
12-1/4"(311)
12-1/4"(311)
14-7/8"(378)
14-7/8"(378)
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH
1-3/8"(35)
1-5/8"(41)
1-7/8"(48)
2-5/8"(67)
2-5/8"(67)
3-1/8"(79)
4-3/8"(111)
4-3/8"(111)
5-1/2"(140)
5-1/2"(140)
WIDTH
3/8"(10)
3/8"(10)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
5/8"(16)
HEIGHT
CATALOG
NUMBER
HUB
SIZE
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5-3/8"
(137)
6-1/16"
(154)
7-1/8"
(181)
9-3/16"
(233)
9-3/16"
(233)
11-5/8"
(295)
15-1/8"
(384)
15-1/8"
(384)
18-1/8"
(460)
18-1/8"
(460)
1-3/8"
(35)
1-5/8"
(41)
2"
(51)
2-5/8"
(67)
2-3/4"
(70)
3-1/2"
(89)
4"
(102)
4-3/4"
(121)
5-1/2"
(140)
5-5/8"
(143)
2"
(35)
2-3/16"
(67)
2-9/16"
(65)
3-1/2"
(89)
3-1/2"
(89)
4-3/16"
(106)
5-3/4"
(146)
5-3/4"
(146)
7-1/8"
(181)
7-1/8"
(181)
1"
(25)
1-7/32"
(31)
1-15/32"
(37)
2"
(51)
2"
(51)
2-9/16"
(65)
3-11/16"
(94)
3-11/16"
(94)
4-7/8"
(124)
4-7/8"
(124)
3-5/32"
(80)
3-25/32"
(96)
4-17/32"
(115)
6"
(152)
6"
(152)
8-1/16"
(205)
10-5/8"
(270)
10-5/8"
(270)
13-1/8"
(333)
13-1/8"
(333)
5/8"
(16)
3/4"
(19)
15/16"
(24)
1-3/16"
(30)
1-3/8"
(32)
1-5/8"
(38)
1-13/16"
(54)
2-3/16"
(54)
2-1/2"
(67)
2-3/4"
(67)
4.0
7.0
12.0
32.0
33.0
70.0
142.0
173.0
292.0
324.0
HUB
SIZE
CATALOG
NUMBER
DIMENSIONS VOLUME
CU. IN.
T TYPE CONDUIT BODY
ABCDEFG
COT-1CG
COT-2CG
COT-3CG
COT-4CG
COT-5CG
COT-6CG
TWOT-7CG
TWOT-8CG
TWOT-9CG
TWOT-0CG
C
O
M
B
O
E
M
T
MO SERIES FITTINGS
IRON AND ALUMINUM MOGUL CONDUIT BODIES F23
FEATURES-SPECIFICATIONS
F
NOTE - For built-in cable rollers (on sizes 1-1/2”and larger), add -WR to cata-
log number. Example: MOLBD-5WR.
NOTE - For built-in cable rollers (on sizes 1-1/2”and larger), add -WR to cata-
log number. Example: MOLBD-5WR.
LB TYPE C TYPE
Suitable for wet locations when
used with gasketed covers.
Federal Specification W-C-586D /
A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10, and 503.10.
Listed
Certified
Applications
Mogul fittings are for use with rigid and IMC
raceways
Use where standard conduit bodies do not pro-
vide adequate access and wiring area for the
pulling of large and heavy conductors
For right angle bends where splices, pulls and
taps are needed in a weather-proof chamber
Features
A raised dome cover permits additional wiring
room
Furnished with captive ss screws and gasket
LBD, C and UB Series available with built-in
cable-pulling rollers on sizes 1-1/2” and larger.
Add -WR to catalog number. Example MOLBD-
5-WR.
Material/Finish
Cast iron moguls are hot dipped galvanized
Aluminum moguls are of copper-free aluminum
(less than 4/10 of 1%) with electrostatically
applied powder coating
HUB
SIZE
CATALOG NUMBER
LB TYPE MOGUL CONDUIT BODY
2-5/16"
(59)
2-5/8"
(67)
3-5/8"
(92)
3-5/8"
(92)
5-5/8"
(143)
5-5/8"
(143)
7-1/2"
(191)
7-1/2"
(191)
9-1/4"
(235)
9-1/4"
(235)
1-5/16"
(33)
1-9/16"
(40)
2-1/2"
(64)
2-1/2"
(64)
3"
(76)
3"
(76)
4-1/2"
(114)
4-1/2"
(414)
5-1/2"
(140)
5-1/2"
(140)
3"
(76)
4-1/2"
(114)
7-1/2"
(191)
7-1/2"
(191)
12"
(305)
12"
(305)
18"
(457)
18"
(457)
24"
(610)
24"
(610)
MOLBD-1M
MOLBD-2M
MOLBD-3M
MOLBD-4M
MOLBD-5M
MOLBD-6M
MOLBD-7M
MOLBD-8M
MOLBD-9M
MOLBD-0M
MOLBD-1
MOLBD-2
MOLBD-3
MOLBD-4
MOLBD-5
MOLBD-6
MOLBD-7
MOLBD-8
MOLBD-9
MOLBD-0
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH ASSEMBLED
HEIGHT
WIDTH 6X LENGTH
KILLARK
ALUM.
KILLARK
IRON
HUB
SIZE
CATALOG NUMBER
C TYPE MOGUL CONDUIT BODY
12"
(305)
12-1/16"
(306)
18-1/8"
(460)
18-1/16"
(459)
27-1/8"
(689)
27-1/4"
(692)
35-3/8"
(899)
35-7/16"
(900)
3"
(76)
3-5/16"
(84)
3-7/8"
(98)
4-7/16"
(113)
5-3/16"
(132)
5-15/16"
(151)
7-3/16"
(183)
7-9/16"
(192)
2-5/8"
(67)
2-5/8"
(67)
3-3/16"
(81)
3-3/16"
(81)
4-11/16"
(119)
4-11/16"
(119)
5-11/16"
(144)
5-11/16"
(144)
10"
(254)
10"
(254)
16"
(406)
16"
(406)
24"
(610)
24"
(610)
32"
(813)
32"
(813)
MOC-3M
MOC-4M
MOC-5M
MOC-6M
MOC-7M
MOC-8M
MOC-9M
MOC-0M
MOC-3
MOC-4
MOC-5
MOC-6
MOC-7
MOC-8
MOC-9
MOC-0
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH ASSEMBLED
HEIGHT
WIDTH 8X LENGTH
KILLARK
ALUM.
KILLARK
IRO N
C Sizes
LB Sizes 2-1/2” thru 4”
LB Sizes 1” thru 2”
NOTE - For built-in cable rollers (on sizes 1-1/2”and larger), add -WR to cata-
log number. Example: MOLBD-5WR.
5"
(127)
6-1/4"
(159)
9-5/8"
(244)
9-5/8"
(244)
14-7/16"
(367)
14-7/16"
(367)
22"
(559)
22"
(559)
28-1/2"
(724)
28-1/2"
(724)
MO SERIES FITTINGS
IRON AND ALUMINUM MOGUL CONDUIT BODIES
F24
FEATURES-SPECIFICATIONS
Suitable for wet locations when
used with gasketed covers.
Federal Specification W-C-586D /
A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Listed
Certified
T TYPE UB TYPE
HUB
SIZE
CATALOG NUMBER
T TYPE
12"
(305)
12-1/16"
(306)
18-1/8"
(460)
18-1/16"
(459)
27-1/8"
(689)
27-1/4"
(692)
35-3/8"
(899)
35-7/16"
(900)
3"
(76)
3-5/16"
(84)
3-7/8"
(98)
4-7/16"
(113)
5-3/16"
(132)
5-15/16"
(151)
7-3/16"
(183)
7-9/16"
(192)
2-5/8"
(67)
2-5/8"
(67)
3-3/16"
(81)
3-3/16"
(81)
4-11/16"
(119)
4-11/16"
(119)
5-11/16"
(144)
5-11/16"
(144)
10"
(254)
10"
(254)
16"
(406)
16"
(406)
24"
(610)
24"
(610)
32"
(813)
32"
(813)
MOT-3M
MOT-4M
MOT-5M
MOT-6M
MOT-7M
MOT-8M
MOT-9M
MOT-0M
MOT-3
MOT-4
MOT-5
MOT-6
MOT-7
MOT-8
MOT-9
MOT-0
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH ASSEMBLED
HEIGHT
WIDTH 8X LENGTH
KILLARK
ALUM.
KILLARK
IRON
HUB
SIZE
CATALOG NUMBER
UB TYPE
10-7/16"
(265)
10-7/16"
(265)
15-9/16"
(395)
15-9/16"
(395)
23-1/16"
(586)
23-5/16"
(668)
30"
(762)
30"
(762)
3-7/8"
(98)
4-3/16"
(106)
5-1/8"
(130)
5-3/4"
(146)
8-1/2"
(216)
8-1/2"
(216)
10-3/8"
(264)
10-3/8"
(264)
2-5/8"
(67)
2-5/8"
(67)
3-3/16"
(81)
3-3/16"
(81)
4-11/16"
(119)
4-11/16"
(119)
5-11/16"
(144)
5-11/16"
(144)
7-1/2"
(191)
7-1/2"
(191)
12"
(305)
12"
(305)
18"
(457)
18"
(457)
24"
(610)
24"
(610)
MOUB-3M
MOUB-4M
MOUB-5M
MOUB-6M
MOUB-7M
MOUB-8M
MOUB-9M
MOUB-0M
MOUB-3
MOUB-4
MOUB-5
MOUB-6
MOUB-7
MOUB-8
MOUB-9
MOUB-0
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
LENGTH ASSEMBLED
HEIGHT
WIDTH 8X LENGTH
KILLARK
ALUM.
KILLARK
IRON
See page F23 for Standard Materials & Finish
Dimensions
T Sizes 2-1/2” thru 4”
UB Sizes 1” thru 2”
UB Sizes 2-1/2” thru 4”
T Sizes 1” thru 2
NOTE - For built-in cable rollers (on sizes 1-1/2”and larger), add -WR to cata-
log number. Example: MOLBD-5WR.
MOL SERIES FITTINGS
MOGUL CONDUIT BODIES F25
FEATURES-SPECIFICATIONS
F
Applications
Mogul fittings are normally used
where the standard “O” Series con-
duit bodies do not offer a sufficient
amount of wiring room
For right angle bends where
splices, pulls and taps are needed
in a weather-proof chamber
Features
A raised dome cover provides
additional wiring room
Furnished with cover and gasket
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
MOL CONDUIT BODIES
MOLB-4* 1-1/4" 5/16" 9-3/4" 2-3/4" 8-1/2" 1" 2-3/8" 9-1/8" 2-3/4"
(8) (248) (70) (445) (25) (60) (232) (70)
MOLB-5 1-1/2" 1-5/16" 13-3/16" 4-3/4" 11-1/2" 2-3/8" 3-1/8" 12-7/8" 3-3/8"
(33) (335) (121) (292) (60) (79) (327) (86)
MOLB-6 2" 1-1/16" 13-3/16" 4-1/4" 11-1/2" 2-1/2" 3-1/8" 12-7/8" 3-3/8"
(27) (335) (108) (292) (64) (79) (327) (86)
MOLB-6CG* 2" 1/16" 14-1/2" 5-3/4" 13" 1-3/8" 3" 14-1/8" 3-5/16"
(2) (368) (146) (330) (35) (76) (359) (84)
MOLB-7 2-1/2" 1-13/16" 22-5/8" 6-1/4" 20" 3-15/16" 4-7/16" 21-13/16" 4-7/16"
(46) (575) (159) (508) (100) (113) (554) (113)
MOLB-8 3" 1-13/16" 22-5/8" 6-1/4" 20" 3-15/16" 4-7/16" 21-13/16" 4-7/16"
(46) (575) (169) (508) (100) (113) (554) (113)
MOLB-9 3-1/2" 1-9/16" 28-11/16" 7-7/8" 25-9/16" 4-3/16" 5-1/2" 28-5/16" 5-1/2"
(40) (729) (200) (649) (106) (140) (719) (140)
MOLB-0 4" 1-9/16" 28-11/16" 7-7/8" 25-7/16" 4-3/16" 5-1/2" 28-5/16" 5-1/2"
(40) (729) (200) (646) (106) (140) (719) (140)
MLB-12* 5" 2-3/8" 43-1/4" 12-1/4" 38-5/8" 6-1/4" 9" 42-1/2" 8-11/16"
(68) (1099) (311) (981) (159) (229) (1080) (221)
CATALOG CONDUIT DIMENSIONS
NUM B E R SIZE ABCDEFG J
Dimensions
MOL BLANK REPLACEMENT COVERS AND GASKETS
MOL-450 1-1/4"
MOL-560 1-1/2" & 2"
MOL-6CG 2"
MOL-780 2-1/2" & 3"
MOL-900 3-1/2" & 4"
MOLB-4
CATALOG NUMBER BODY STYLE
*Split cover design
MOLB-6CG MLB-12
MOLB-5 thru 0
Suitable for wet locations when
used with gasketed covers.
Federal Specification W-C-586D /
A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502-.10 and 503.10.
NECLB SERIES FITTINGS
40% FILL CONDUIT BODIES
F26
FEATURES-SPECIFICATIONS
NECLB-6
Listed - File E3397
See files for details or call Ki l l a r k .
NECLB CONDUIT BODIES
Dimensions
Applications
Specially designed to meet
National Electrical Code Article
370-28(a) (2) for angle pulls where
the distance between the raceway
entry and the opposite wall of the
fitting must be at least six times the
trade diameter of the raceway.
CATALOG REPLACEMENT HUB
NUM B E R COVER AN D GASKET S I Z E ABCDEFG H J K
NECLB-3 NECLB-30 1" 8-1/8" 3-7/16" 2" 11-9/32" 6" 2" 1-1/8" 3-1/8" 7" 1 NPT
NECLB-4 NECLB-40 1-1/4" 9-7/8" 4-1/16" 2-3/8" 11-5/16" 7-1/2" 2-1/2" 1-3/16" 3-11/16" 8-5/8" 1-1/4 NPT
NECLB-5 NECLB-50 1-1/2" 11-17/32" 5-1/16" 2-3/4" 2-3/16" 9" 3-1/2" 1-3/16" 4-11/16" 10-5/8" 1-1/2 NPT
NECLB-6 NECLB-60 2" 14-25/32" 6-3/16" 3" 2-11/16" 12" 4" 1-3/16" 5-3/16" 13-11/16" 2 NPT
A pull box with easy access to
conductors
A chamber with a large opening
for easy access to perform
changes in the conduit system
For 90° bends in a conduit system
Includes cover and gasket
Features
Large cover opening (length of opening
exceeds six times the trade diameter
of the hub size) for easy access to
conductors. Cover and gasket included
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Suitable for wet locations when
used with gasketed covers.
Federal Specification W-C-586D /
A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502-.10 and 503.10.
SLB/SLBM/SOLB/MLB SERIES FITTINGS
SERVICE ENTRANCE STANDARD AND HOSTILE LOCATIONS F27
FEATURES-SPECIFICATIONS
F
Suitable for wet locations when
used with gasketed covers.
Federal Specification W-C-586D /
A-A 50563.
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10 and 503.10.
Features
Designed for easier wire pulling
Includes Cover and Gasket
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Listed - File E22698
Certified - File LR11852
See files for details or call Killark
MLB-12
SOLB-8, 9, 0
CATALOG CONDUIT
NUMBER SIZE ABCDE F
SLB-1 1/2" 2-3/4" 1-1/16" 2-3/8" 3/4" 1-3/8" 1-3/16"
(70) (27) (60) (19) (35) (30)
SLB-2 3/4" 3-1/8" 1-3/8" 2-11/16" 7/8" 1-11/16" 1-3/8"
(79) (35) (68) (22) (43) (35)
SLB-3 1" 3-3/4" 1-5/8" 3-1/4" 15/16" 1-15/16" 1-3/4"
(95) (41) (83) (24) (49) (44)
SLB-4 1-1/4" 5" 2" 4-5/16" 1-1/4" 2-1/2" 2-3/16"
(127) (51) (110) (32) (64) (56)
SLBM-4 1-1/4" 7-1/4" 1-15/16" 6-3/8" 15/16" 2-5/8" 2-1/2"
(184) (49) (162) (24) (67) (64)
SLB-5 1-1/2" 5-3/4" 2-7/16" 4-3/4" 1-1/2" 2-9/16" 2-7/16"
(147) (62) (121) (38) (65) (62)
SLB-6 2" 6-1/4" 2-15/16" 5" 1-5/8" 3-1/8" 2-13/16"
(159) (75) (127) (41) (79) (71)
SLBM-6 2" 9-1/2" 2-11/16" 8-9/16" 11-3/16" 3-7/16" 3-1/8"
(241) (68) (217) (284) (87) (79)
SLB-7 2-1/2" 8" 3-9/16" 6-7/8" 11-5/16" 4" 3-1/2"
(203) (90) (175) (287) (102) (89)
SOLB-8 3" 12-1/4" 4-7/16" 10-7/16" 11-3/16" 6-1/4" 4-7/16"
(311) (113) (265) (284) (159) (113)
SOLB-9 3-1/2" 15" 5" 11-7/8" 3-1/8" 7-1/2" 5-1/2"
(381) (127) (302) (79) (191) (140)
SOLB-0 4" 15" 5" 11-7/8" 3-1/8" 7-1/2" 5-1/2"
(381) (127) (302) (79) (191) (140)
MLB-12 5" 42-1/2" 8-11/16" 38-5/8" 4-5/8" 12-1/4" 9"
(1080) (221) (981) (118) (311) (229)
SERVICE ENTRANCE BODIES
SLB-1 thru 7
SLBM-4
WH SERIES FITTINGS
CONDUIT HUBS
F28
FEATURES-SPECIFICATIONS
A
1.500"
1.510"
1.812"
1.877"
1.920"
1.895"
2.605"
2.615"
2.570"
2.590"
Listed
Certified
WH WEATHERPROOF CONDUIT HUBS
CATALOG NPT
NUMBER HUB SIZE
WH-1 1/2"
WH-2 3/4"
WH-3 1"
WH-4 1-1/4"
WH-5 1-1/2"
WH-6 2"
WH-7 2-1/2"
WH-8 3"
WH-9 3-1/2"
WH-0 4"
DIMENSIONS
WH
Applications
Conduit hubs provide a liquid tight, oil
tight and dust tight termination of elec-
trical conduit through the walls of
sheet metal enclosures. The hubs fit
into standard knock-out dimensions.
Features
Oversized locknut provides for a
strong vibration-proof termination
Captive sealing ring
Serrations on hub body and locknut
provide effective positive ground path
Rugged cast zinc construction
Insulated throat protects conductors
Suitable for use with NEMA type
enclosures 2, 3, 3R, 4, 12 and 13
Material/Finish
Die cast zinc
Natural finish
Sealing ring - Buna-N
A
B
“C”NPSM-2A
Thread
CATA LOG
NUMBER
W H - 1
W H - 2
W H - 3
W H - 4
W H - 5
W H - 6
W H - 7
W H - 8
W H - 9
W H - 0
B
1.437"
1.685"
1.921"
2.370"
2.745"
3.236"
3.708"
4.370"
4.941"
5.450"
C
1/2"-14
3/4"-14
1"-11-1/2
1-1/4"-11-1/2
1-1/2"-11-1/2
2"-11-1/2
2-1/2"-8
3"-8
3-1/2"-8
4"-8
Suitable for use in hazardous loca-
tion applications when installed
according to NEC Articles
501.10(b), Class I, Div. 2, (Suitable
for use in Class I Zone 2 applica-
tions) 502.10, 503.10 and 505-15.
Suitable for use with NEMA type
enclosures 2, 3, 3R, 4, 12 and 13.
CL/CLM/SOLB/TWCL/DS SERIES FITTINGS
PULLING ELBOW & DUCT SEAL STANDARD AND HOSTILE LOCATIONS F29
FEATURES-SPECIFICATIONS
F
Listed - FileE E22699
Certified - File LR11852
See files for details or call Killark.
TWCL-2
CATALOG HUB
NUMBER SIZE TYPE
CL-1 1/2"
CL-2 3/4" CL
CL-3 1"
CLM-1 1/2"
CLM-2 3/4" CLM
CLM-3 1"
PULLING ELBOWS
FOR THREADED CONDUIT
1Raintight/concrete tight
2Set screw in each hub
CATA LOG HUB
NUMBER SIZE
TWCL-1 1/2"
TWCL-2 3/4"
PULLING ELBOWS
FOR THINWALL CONDUIT2
CATALOG
NUMBER SIZE
DS-1 1-lb.
DS-5 5-lb.
Duct Seal is a soft, non-hardening
weather-proof compound, easily
applied in all working temperatures.
It is non-staining, can be painted,
is an excellent moisture barrier for
weather-sealing service entries,
electrical cables, conduit ducts, etc.
Applications
90° pulling elbows are used to
accommodate pulling conductors
through a sharp bend in the con-
duit system
Features
Designed for easier wire pulling
Includes Cover and Gasket
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
CLM-21
CL-31
Duct Seal
SIZE ABC DE
1/2" 1-1/4" (32) 2-9/16" (65) 1-3/8" (35) 1-1/4" (32) 1-7/16" (37)
3/4" 1-3/8" (35) 2-3/4" (70) 1-9/16" (40) 1-3/8" (35) 1-17/32" (39)
1" 1-3/4" (44) 3-1/8" (79) 1-3/4" (44) 1-3/4" (44) 1-23/32" (44)
DIMENSIONS
DUCT SEAL
FB/STFB SERIES FITTINGS
SERVICE ENTRANCE STANDARD AND HOSTILE LOCATIONS
F30
FEATURES-SPECIFICATIONS
Listed - File E22698
See files for details or call Killark.
CATALOG HUB KNOCKOUTS DIMENSIONS
NUMBER SIZE QUANTITY DIAMETER WIDTH HEIGHT
FB-714 1/2" 4 3/8” 3.00" (76) 2.60" (66)
FB-724 3/4" 5 3/8” 2.39" (61) 2.32" (58)
FB-734 1" 5 1/2” 2.62" (67) 3.03" (80)
FB-745 1-1/4" 5 1/2” 2.62" (67) 3.03" (80)
One 1/2”
FB-765 2" 6 Two 3/4” 4.43" (113) 4.45" (113)
Three 1”
FB-787 3" 7 Four 1” 6.40" (163) 8.00" (203)
Three 1-1/4”
FB-707 4" 7 Four 1-3/4” 8.00" (163) 9.00" (229)
Two 1-1/8”
FB SERVICE ENTRANCE
CATALOG HUB KNOCKOUTS DIMENSIONS
NUMBER SIZE QUANTITY DIAMETER WIDTH HEIGHT
STFB-2 3/4" 5 3/8” 2.39" (61) 2.32" (59)
STFB-3 1" 5 1/2” 2.62" (67) 3.03" (77)
STFB-4 1-1/4" 5 1/2” 2.62" (67) 3.03" (77)
One 1/2”
STFB-5 1-1/2" 6 Two 5/8” 3.43" (87) 3.75" (95)
Three 3/4”
One 1/2”
STFB-6 2" 6 Two 3/4” 4.43" (113) 4.45" (113)
Three 1”
STFB-7 2-1/2" 7 Four 1” 6.40" (163) 8.00" (203)
Three 1-1/4”
STFB-8 3" 7 Four 1” 6.40" (163) 8.00" (203)
Three 1-1/4”
STFB-0 4" 7 Four 1-1/4" 8.00" (203) 9.00" (229)
STFB SERVICE ENTRANCE
For rigid or thinwall conduit (EMT)
Applications
For overhead service entrance
For use with EMT or rigid conduit
Features
For use with aluminum or steel
conduit
Mounting clamp provides easy
installation
Insulators included
Three point balance for proper
alignment
Variety of knockout arrangements
Vertical mounting
Sizes 3/4" thru 4" available
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Natural finish
FB STFB
Weather-proof for threaded conduit.
Applications
For overhead service entrance
For use with threaded rigid conduit
Features
For use with aluminum or steel
conduit
Insulators included
Easy installation and assembly
Variety of knockout arrangements
Vertical mounting
Sizes 1/2" thru 4" available
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Natural finish
FS/FD/FSC SERIES FITTINGS
CAST DEVICE BOXES STANDARD AND HOSTILE LOCATIONS F31
FEATURES-SPECIFICATIONS
F
HUB
SIZE
VOLUME
CU. IN.
FS TYPE CAST DEVICE BOX – SHALLOW – DEAD END
7/8"
(22)
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
2-7/8"
(73)
2-1/8"
(54)
2-1/8"
(54)
2-1/8"
(54)
5-3/8"
(136)
18.0
18.0
18.0
1/2"
3/4"
1"
A BCDE FG
DIMENSIONS
VOLUME
CU. IN.
FD TYPE CAST DEVICE BOX – DEEP – DEAD END
7/8"
(22)
7/8"
(22)
7/8"
(22)
2-7/8"
(73)
2-7/8"
(73)
2-7/8"
(73)
11/16"
(17)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
2-7/8"
(73)
2-1/8"
(54)
2-1/8"
(54)
2-1/8"
(54)
28.0
28.0
28.0
FD-1M
FD-2M
FD-3M
FD-1
FD-2
FD-3
1/2"
3/4"
1"
A BCDE FG
DIMENSIONS
Applications
Accommodates wiring devices and
provides opening to splice, tap, or
pull conductors
Provide access to conductors for
maintenance and future system
changes
Features
Tapered threads (NPT with integral
bushings)
Internal grounding screw
Optional mounting feet available
on FS, FD, FSC, and FDC
Available single and two gang
styles
Suitable for use in wet locations
when used with gasket covers
Cast iron is suitable for concrete use
For use with FS-style covers see
pages F40-F42
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Duraloy Iron
Tri-coat finish of electrozinc, chro-
mate sealant, and electrostatically
applied powder coating
FD-1&2
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Listed File No. E 3397
Certified File No. LR11852
FS 1 & 2 with Lugs FD 1 & 2 with lugs
Dimensions
CATALOG NUMBER
KILLARK
ALUM.
DURALOY
IRON
FS-1M
FS-2M
FS-3M
FS-1
FS-2
FS-3
CATALOG NUMBER HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
FS-1&2
FSC 1 & 2 with lugs
VOLUME
CU. IN.
FSC TYPE CAST DEVICE BOX – SHALLOW – FEED THRU
7/8"
(22)
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
2-7/8"
(73)
2-1/8"
(54)
2-1/8"
(54)
2-1/8"
(54)
5-3/8"
(136)
5-3/8"
(136)
5-3/8"
(136)
18.0
18.0
18.0
FSC-1M
FSC-2M
FSC-3M
FSC-1
FSC-2
FSC-3
1/2"
3/4"
1"
A BCDE FG
DIMENSIONS
FSC
CATALOG NUMBER HUB
SIZE
KILLARK
ALUM.
DURALOY
IRO N
FDC/FSOC/FSL SERIES FITTINGS
CAST DEVICE BOXES STANDARD AND HOSTILE LOCATIONS
F32
FEATURES-SPECIFICATIONS
Applications
Accommodates wiring devices and
provides opening to splice, tap, or
pull conductors
Provide access to conductors for
maintenance and future system
changes
Features
Tapered threads (NPT with integral
bushings)
Internal grounding screw
Optional mounting feet available
on FS, FD, FSC, and FDC
Available single and two gang styles
Suitable for use in wet locations
when used with gasket covers
Cast iron is suitable for concrete use
For use with FS-style covers see
pages F40-F42
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Duraloy Iron
Tri-coat finish of electrozinc, chro-
mate sealant, and electrostatically
applied powder coating
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Listed File No. E 3397
Certified File No. LR11852
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FDC TYPE CAST DEVICE BOX – DEEP – FEED THRU
7/8"
(22)
7/8"
(22)
7/8"
(22)
2-7/8"
(73)
2-7/8"
(73)
2-7/8"
(73)
11/16"
(17)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
2-7/8"
(73)
2-1/8"
(54)
2-1/8"
(54)
2-1/8"
(54)
5-3/8"
(136)
5-3/8"
(136)
5-3/8"
(136)
28.5
28.5
28.5
FDC-1M
FDC-2M
FDC-3M
FDC-1
FDC-2
FDC-3
1/2"
3/4"
1"
ABCD E FG
DIMENSIONS
FDC 1 & 2 with lugs FSOC Type
FDC - 1 & 2 FSOC
KILLARK
ALUM.
DURALOY
IRON
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FSL TYPE CAST DEVICE BOX – SHALLOW
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
18.0
18.0
FSL-1M
FSL-2M
FSL-1
FSL-2
1/2"
3/4"
A BCDE FG
DIMENSIONS
FSL
FSL Type
KILLARK
ALUM.
DURALOY
IRON
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FSOC TYPE CAST DEVICE OPEN BOX – SHALLOW – FEED THRU
7/8"
(22)
3"
(76)
1-1/2"
(138)
4-5/8"
(117)
2-7/8"
(73) 29.0
FSOC-1
A BCDE FG
DIMENSIONS
1/2"
KILLARK
ALUMINUM
Dimensions
FRS/FST SERIES FITTINGS
CAST DEVICE BOXES STANDARD AND HOSTILE LOCATIONS F33
FEATURES-SPECIFICATIONS
F
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Listed File No. E 3397
Certified File No. LR11852
Applications
Accommodates wiring devices and
provides opening to splice, tap, or
pull conductors
Provide access to conductors for
maintenance and future system
changes
Features
Tapered threads (NPT with integral
bushings)
Internal grounding screw
Optional mounting feet available
on FS, FD, FSC, and FDC
Available single and two gang styles
Suitable for use in wet locations
when used with gasket covers
Cast iron is suitable for concrete use
For use with FS-style covers see
pages F40-F42
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Duraloy Iron
Tri-coat finish of electrozinc, chro-
mate sealant, and electrostatically
applied powder coating
Dimensions
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FSR TYPE CAST DEVICE BOX – SHALLOW
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
18.0
18.0
FSR-1M
FSR-2M
FSR-1
FSR-2
1/2"
3/4"
ABCD E FG
DIMENSIONS
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FST TYPE CAST DEVICE BOX – SHALLOW
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
18.0
18.0
FST-1
FST-2
FST-1M
FST-2M
1/2"
3/4"
ABCDEF G
DIMENSIONS
FSR FST
FSR Type FST Type
KILLARK
ALUM.
DURALOY
IRO N
KILLARK
ALUM.
DURALOY
IRO N
FSX/FSA/FDA/FSLB SERIES FITTINGS
CAST DEVICE BOXES STANDARD AND HOSTILE LOCATIONS
F34
FEATURES-SPECIFICATIONS
FSX TYPE CAST DEVICE BOX – SHALLOW
CATALOG NUMBER DIMENSIONS
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Listed File No. E 3397
Certified File No. LR11852
FSX FSA FDA FSLB
FSX Type
Applications
Accommodates wiring devices and
provides opening to splice, tap, or
pull conductors
Provide access to conductors for
maintenance and future system
changes
Features
Tapered threads (NPT with integral
bushings)
Internal grounding screw
Optional mounting feet available
on FS, FD, FSC, and FDC
Available single and two gang styles
Suitable for use in wet locations
when used with gasket covers
Cast iron is suitable for concrete use
For use with FS-style covers see
pages F40-F42
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Duraloy Iron
Tri-coat finish of electrozinc, chro-
mate sealant, and electrostatically
applied powder coating
KILLARK
ALUM.
DURALOY
IRON
1/2"
3/4"
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
18.0
18.0
BCD E FG
VOLUME
CU. IN.
HUB
SIZE A
FSX-1M
FSX-2M
FSX-1
FSX-2
Dimensions
FSA/FDA Types FSLB Type
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FSA TYPE CAST DEVICE BOX – SHALLOW – DEAD END
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
18.0
18.0
FSA-1
FSA-2
ABCDEF G
DIMENSIONS
1/2"
3/4"
KILLARK
ALUMINUM
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FDA TYPE CAST DEVICE BOX – DEEP – DEAD END
7/8"
(22)
2-7/8"
(73)
11/16"
(17)
4-5/8"
(117)
2-7/8"
(73) 28.5
FDA-2
A BCDE FG
DIMENSIONS
3/4"
KILLARK
ALUMINUM
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FSLB TYPE CAST DEVICE BOX – SHALLOW – FEED THRU
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
18.0
18.0
FSLB-1
FSLB-2
A BCDE FG
DIMENSIONS
1/2"
3/4"
KILLARK
ALUMINUM
— —
FSS/FSCC/FDCC SERIES FITTINGS
CAST DEVICE BOXES STANDARD AND HOSTILE LOCATIONS F35
FEATURES-SPECIFICATIONS
F
Dimensions
Applications
Accommodates wiring devices and
provides opening to splice, tap, or
pull conductors
Provide access to conductors for
maintenance and future system
changes
Features
Tapered threads (NPT with integral
bushings)
Internal grounding screw
Available single and two gang
styles
Suitable for use in wet locations
when used with gasket covers
Cast iron is suitable for concrete
use
For use with FS-style covers see
pages F40-F42
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Duraloy Iron
Tri-coat finish of electrozinc, chro-
mate sealant, and electrostatically
applied powder coating
FSS/FDS Types FSCC/FDCC Types
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FSS TYPE CAST DEVICE BOX – SHALLOW
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
18.0
18.0
FSS-1M
FSS-2M
FSS-1
FSS-2
1/2"
3/4"
ABCD E FG
DIMENSIONS
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FSCC TYPE CAST DEVICE BOX - SHALLOW
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
18.0
18.0
FSCC-1M
FSCC-2M
FSCC-1
FSCC-2
1/2"
3/4"
A BCDE FG
DIMENSIONS
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FDCC TYPE CAST DEVICE BOX – DEEP
7/8"
(22)
2-7/8"
(73)
11/16"
(17)
4-5/8"
(117)
2-7/8"
(73) 28.5
FDCC-2 FDCC-2M 3/4"
ABCDEFG
DIMENSIONS
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Listed File No. E 3397
Certified File No. LR11852
KILLARK
ALUM.
DURALOY
IRON
KILLARK
ALUM.
DURALOY
IRO N
FSCC FDCC
FSS
KILLARK
ALUM.
DURALOY
IRO N
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FDS TYPE CAST DEVICE BOX
7/8"
(22)
2-7/8"
(73)
11/16"
(17)
4-5/8"
(117)
2-7/8"
(73) 8.5
FDS-2 FDS-2M 3/4"
ABCDEFG
DIMENSIONS
KILLARK
ALUM.
DURALOY
IRON
FSCA/FSCT SERIES FITTINGS
CAST DEVICE BOXES STANDARD AND HOSTILE LOCATIONS
F36
FEATURES-SPECIFICATIONS
Applications
Accommodates wiring devices and
provides opening to splice, tap, or
pull conductors
Provide access to conductors for
maintenance and future system
changes
Features
Tapered threads (NPT with integral
bushings)
Internal grounding screw
Available single and two gang
styles
Suitable for use in wet locations
when used with gasket covers
Cast iron is suitable for concrete
use
For use with FS-style covers see
pages F40-F42
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Duraloy Iron
Tri-coat finish of electrozinc, chro-
mate sealant, and electrostatically
applied powder coating
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FSCA TYPE CAST DEVICE BOX – SHALLOW
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
18.0
18.0
FSCA-1M
FSCA-2M
FSCA-1
FSCA-2
1/2"
3/4"
ABCD E FG
DIMENSIONS
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
FSCT TYPE CAST DEVICE BOX – SHALLOW
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
2-7/8"
(73)
2-7/8"
(73)
18.0
18.0
FSCT-1M
FSCT-2M
FSCT-1
FSCT-2
1/2"
3/4"
A BCDE FG
DIMENSIONS
FSCT TypeFSCA Type
FSCTFSCA
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Listed File No. E 3397
Certified File No. LR11852
KILLARK
ALUM.
DURALOY
IRON
KILLARK
ALUM.
DURALOY
IRON
Dimensions
2FS/2FD SERIES FITTINGS
CAST DEVICE BOXES STANDARD AND HOSTILE LOCATIONS F37
F
FEATURES-SPECIFICATIONS
2FS Type 2FD Type2FSC Type
2FS 2FD 2FDC
2FSC
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
2FS TYPE CAST DEVICE BOX TWO GANG – SHALLOW
7/8"
(22)
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
4-5/8"
(117)
4-11/16"
(119)
4-11/16"
(119)
4-11/16"
(119)
32.0
32.0
32.0
2FS-1M
2FS-2M
2FS-3M
2FS-1
2FS-2
2FS-3
1/2"
3/4"
1"
A BCDE FG
DIMENSIONS
2FD TYPE CAST DEVICE BOX TWO GANG – DEEP
7/8"
(22)
7/8"
(22)
2-15/16"
(75)
2-15/16"
(75)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
4-11/16"
(119)
4-11/16"
(119)
47.0
47.0
2FD-1M
2FD-2M
2FD-1
2FD-2
1/2"
3/4"
2FDC TYPE CAST DEVICE BOX TWO GANG – DEEP
7/8"
(22)
7/8"
(22)
2-15/16"
(75)
2-15/16"
(75)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
4-11/16"
(119)
4-11/16"
(119)
50.0
50.0
2FDC-1M
2FDC-2M
2FDC-1
2FDC-2
1/2"
3/4"
2FSD TYPE CAST DEVICE BOX TWO GANG – SHALLOW
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
4-11/16"
(119)
4-11/16"
(119)
32.0
32.0
2FSD-1M
2FSD-2M
2FSD-1
2FSD-2
1/2"
3/4"
2FSC TYPE CAST DEVICE BOX TWO GANG – SHALLOW
7/8"
(22)
7/8"
(22)
2"
(51)
2"
(51)
11/16"
(17)
11/16"
(17)
4-5/8"
(117)
4-5/8"
(117)
4-11/16"
(119)
4-11/16"
(119)
32.0
32.0
2FSC-1M
2FSC-2M
2FSC-1
2FSC-2
1/2"
3/4"
UL Standard: 514A
CSA Standard: C22.2 No. 18
Fed Spec: W-C-586D
NEMA: FB-1
Listed File No. E 3397
Certified File No. LR11852
Applications
Accommodates wiring devices and
provides opening to splice, tap, or
pull conductors
Provide access to conductors for
maintenance and future system
changes
Features
Tapered threads (NPT with integral
bushings)
Internal grounding screw
Available single and two gang styles
Suitable for use in wet locations
when used with gasket covers
Cast iron is suitable for concrete
use
For use with FS-style covers see
pages F40-F42
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Duraloy Iron
Tri-coat finish of electrozinc, chro-
mate sealant, and electrostatically
applied powder coating
KILLARK
ALUM.
DURALOY
IRON
2FDC Type
Dimensions
2FSD Type
2 & 3 F S / F D S E R I E S FITTINGS
CAST DEVICE BOXES STANDARD AND HOSTILE LOCATIONS
F38
FEATURES-SPECIFICATIONS
FS/FD MULTI GANG BOXES1
Two Gang
2FS 2FD 3FS 3FD
Three Gang
Applications
Accommodates wiring devices and
provides opening to splice, tap, or
pull conductors
Provide access to conductors for
maintenance and future system
changes
Features
Internal grounding screw
Available single and two gang
styles
Suitable for use in wet locations
when used with gasket covers
For use with FS-style covers see
pages F40-F42
Conduit Opening Data
To specify conduit openings select
the letter on these sketches which
indicates the position desired.
Follow this letter with the symbol
indicating the type and size.
Example: 2FS-A2-E2
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
1Union hubs are supplied by using a drilled and tapped opening with GUM Series union on 1/2",
3/4", 1", 1-1/4" and 1-1/2" sizes.
Two Gang Three Gang
Single Gang
1/2" 1 11
3/4" 2 12
1" 3 13
1-1/4" 4 14
1-1/2" 5 15
FOR UNION1
CONDUIT THREADED SYMBOL
SIZE SYMBOL NUMBER NUMBER
FS/FD/FSQ/FDQ CONDUIT OPENING AND SYMBOL IDENTIFICATION
SERIES ABCD EH
FSQ 3-3/4"(95) 3-9/16"(90) 1/4"(6) 4-9/16"(116) 2-13/16"(71) 2"(51)
2FS 6-3/16"(157) 3-3/4"(95) 9/32"(7) 4-7/8"(124) 4-15/16"(125) 2"(51)
3FS 6-3/16"(157) 5-3/4"(146) 9/32"(7) 4-7/8"(124) 6-3/4"(125) 2"(51)
FDQ 3-3/4"(95) 3-9/16"(90) 1/4"(6) 4-9/16"(116) 2-13/16"(71) 2-7/8"(73)
2FD 6-3/16"(157) 3-3/4"(95) 9/32"(7) 4-7/8"(124) 4-15/16"(125) 2-7/8"(73)
3FD 6-3/16"(157) 5-3/4"(146) 9/32"(7) 4-7/8"(124) 6-3/4"(125) 2-7/8"(73)
FSQ/FDQ SERIES FITTINGS
CUSTOM DRILLED & TAPPED DEVICE BOXES
STANDARD AND HOSTILE LOCATIONS
F39
FEATURES-SPECIFICATIONS
F
Listed - File E3397
Certified - File LR11852
See files for details or call Killark.
FDQ 2FDQ
FSQ/FDQ DRILLED AND TAPPED DEVICE BOXES
SERIES ABCD EH
FSQ 3-3/4"(95) 3-9/16"(90) 1/4"(6) 4-9/16"(116) 2-13/16"(71) 2"(51)
2FSQ 5-7/8"(149) 4-1/4"(108) 5/16"(8) 4-7/8"(124) 6-7/16"(164) 2"(51)
3FSQ 6-1/8"(156) 7-1/2"(191) 5/16"(8) 4-15/16"(125) 9-13/16"(249) 2"(51)
FDQ 3-3/4"(95) 3-9/16"(90) 1/4"(6) 4-9/16"(116) 2-13/16"(71) 2-7/8"(73)
2FDQ 6-3/16"(157) 4-7/16"(113) 5/16"(8) 4-7/8"(124) 6-7/16"(164) 2-7/8"(73)
3FDQ 5-7/8"(149) 7-9/16"(192) 5/16"(8) 4-15/16"(125) 9-13/16"(249) 2-7/8"(73)
4FDQ 5-7/8"(149) 10-13/16"(275) 5/16"(8) 4-15/16"(125) 13-1/8"(333) 2-7/8"(73)
To specify conduit opening combi-
nation select the letter on the
sketch which indicates the position
of the opening desired. Follow this
letter with the symbol indicating the
type of opening-threaded, thread-
less or union
Maximum Conduit Opening Size
FS-1/2" thru 1"
FD-1/2" thru 1-1/2"
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Conduit Opening Data
To specify conduit openings selet
the letter on these sketches which
indicates the position desired.
Follow this letter with the symbol
indicating the type and size.
Example: 2FS-A2-E2-J13
All conduit openings will be evenly
spaced. When they are to be more
accurately located, submit a sketch
with spacing dimensions.
Dimensions should be oriented
from centerlines of body and out-
side backof body.
FS and FSQ box will take drilled
and tapped openings thru 1".
FD and FDQ box will take drilled
and tapped openings thru 1-1/2".
1/2" 1 11
3/4" 2 12
1" 3 13
1-1/4" 4 14
1-1/2" 5 15
FOR CONDUIT THREADED UNION1
SIZE SYMBOL NUMBER SYMBOL NUMBER
FS/FD/FSQ/FDQ CONDUIT OPENING AND SYMBOL IDENTIFICATION
1Union hubs are supplied by using a drilled
and tapped opening with GUM Series union on
1/2", 3/4", 1", 1-1/4" and 1-1/2" sizes.
Two Gang Three Gang Four Gang
Single Gang
3FDQ
Three GangTwo GangSingle Gang Four Gang
4FDQ
Applications
Accommodates wiring devices and
provides opening to splice, tap, or
pull conductors
Provide access to conductors for
maintenance and future system
changes
Features
The fittings on this page takes single
gang covers listed on pages F40-F42
FSQ and FDQ series boxes are
made with individual cover openings
so any combination of devices may
be assembled
Any assembly is suitable for wet
and damp locations when it con-
sists of these boxes and a cover
suitable for wet and damp locations
FS/FD SERIES FITTINGS
DEVICE BOX COVERS STANDARD AND HOSTILE LOCATIONS
F40
FEATURES-SPECIFICATIONS
SINGLE GANG
Listed File No. E 3397
Certified File No. LR11852
1FA Type1FB Type 2FT Type
Stamped metallic covers with or without electrostatically applied powder coating
Gaskets to be ordered separately
CATALOG NUMBER
WITH WITHOUT
COATING COATING
Blank for Single Gang
Boxes
1FBC 1FB
1 Toggle Switch
1FTC 1FT
1 Duplex Receptacle
1FAC 1FA
1-13/32" Opening Round
Receptacle
1FRC 1FR
1-5/8" Opening
Round Receptacle
1FGC 1FG
THREE GANG
CATALOG
NUMBER DESCRIPTION
3FB
3FT
3FA
Blank
for 3
Gang Boxes
3 Toggle
Switches
3 Duplex
Receptacles
TWO GANG
CATALOG NUMBER
WITH WITHOUT
COATING COATING
Blank for Two Gang Boxes
2FBC 2FB
2 Toggle Switches
2FTC 2FT
2 Duplex Receptacles
2FAC 2FA
Toggle Switch & Duplex
Receptacle
2FTAC 2FTA
1-13/32" Openings
2 Round Receptacles
2FRC 2FR
1-5/8" Opening Round
2 Round Receptacles
2FGC 2FG
REPLACEMENT GASKETS FOR COVERS
(NEOPRENE RUBBER)
FSRG
2FSRG
3FSRG
CATALOG
NUMBER DESCRIPTION
Neoprene Gaskets
for Single Gang
Boxes
Neoprene Gaskets
for 2 Gang
Boxes
Neoprene Gaskets
for 3 Gang
Boxes
FZ/FCL-GF/FST SERIES FITTINGS
DEVICE BOX COVERS STANDARD AND HOSTILE LOCATIONS F41
FEATURES-SPECIFICATIONS
F
Blank for
2 Gang Boxes
2 Toggle Switches
3 Toggle Switches
Blank for 3
Gang Boxes
FCL-GF Type FST Type
FZ8647
Cast metallic covers with electrostatically applied powder coating
Listed File No. E 3397
Certified File No. LR11852
CAST DEVICE COVERS— SINGLE GANG
(GASKETS INCLUDED)
CATALOG
NUMBER DESCRIPTION
FSBC
FZ8648
FZ8647
FST
FSPT
FSTG
Blank for Single
Gang Boxes
Square Toggle
Lock in ON or OFF
Position
Square Toggle
(Long Throw —
Such as Manual
Starters)
1 Toggle Switch
For Toggle Switch
Toggle Switch
Guarded
CAST DEVICE COVERS— SINGLE GANG
(GASKETS INCLUDED)
CATA LOG
NUMBER DESCRIPTION
FCLA
FCLT
FCLR
FCLG
FCLM
FCLN
FCL-GF
FCL-VG
Duplex
Receptacle
Toggle Switch
Round
Receptacle
1.406" Dia.
Round
Receptacle
1.625" Dia.
Round
Receptacle
1.750" Dia.
Round
Receptacle
2.156" Dia.
Device Cover
for Most
Manufacturers’ GFI
Devices
Includes Gaskets
and Screws
Replacement
Vellumoid
Gasket
CAST DEVICE COVERS—TWO AND
THREE GANG (GASKETS INCLUDED)
CATA LOG
NUMBER DESCRIPTION
2FSBC
2FST
3FST
3FSBC
FSBCM Iron Blank for
Single Gang Boxes 2FSBCM Iron Blank for
2 Gang Boxes
Duplex Wall Plate for horizontal
mounting on FS/FD Boxes. Cast
aluminum, gasketed and self-closing.
Listed for wet locations with cover
open in continuous use.
FCLA2
FCL/FZ/PL SERIES FITTINGS
DEVICE BOX ACCESSORIES STANDARD AND HOSTILE LOCATIONS
F42
FEATURES-SPECIFICATIONS
Applications
Use in dirty, dusty or corrosive areas
lndoor/outdoor applications
Where devices need physical
protection
Features
May be used with several different
manufacturers’ GFI devices
Mounts on all FS, FD, FSQ and
FDQ Series boxes (single opening)
Snap type lid. UL/CSA suitable for
wet locations.
Gaskets included
FCL
Device Covers
(For GFI Receptacles)
Applications
Suitable for NEMA 3 locations
Areas where dust or dirt are a
problem
With standard toggle switches or
manual motor starters
Features
Copper-free aluminum
Gaskets included
Three toggle operator choices
Lock “ON” or “OFF” provision
standard
Stainless steel screws
Mounts on all FS, FD, FSQ and
FDQ Series boxes (single opening)
FZ PL
Applications
Wet and damp locations
Areas where dirt, dust or corrosion
is a problem
Washdown areas such as food
processing plants or dairies
Features
Non corrosive yellow polyethylene
ring
Molded neoprene boot on plug
Listed - File E3397
Certified - File LR11852
Listed - File E3397
Certified - File LR11852
CATALOG ITEM
NUMBER
FCL-GF
Device cover
includes gaskets
and screws
FCL-VG
Replacement
Vellumoid
gasket
CATALOG NEMA CONFIGURATION
NUMBER AND RATING
Cord diameter
PL-7 .375(9)/.625(16)
CATALOG TYPE OF TOGGLE
NUMBER SWITCH HANDLE
FZ8648 Square toggle
Square toggle
FZ8647 (Long throw-such as
manual starters)
FZ Round toggle
FCL-GF FZ-8647 PL
Not CSA approved.
VJ SERIES FITTINGS
OUTLET BOXES STANDARD AND HOSTILE LOCATIONS F43
FEATURES-SPECIFICATIONS
F
Applications
VJ Series round boxes are available
in three depths for use as splice
boxes, for hanging pendant fixtures
by using hub covers; or by using a
VBA plate (see page L11), will take
VFC fixture caps
Cover mounting centers are 3-1/2"
and will accommodate 4" round or
octagonal box covers and devices.
Screw holes are 8-32 size
VJ Series are furnished with four
“X” conduit openings and three
close-up plugs
Gaskets are required for wet and
damp locations
Features
Complies with NEMA 3, 4 and IPx6
(when gasketed)
Supports up to 125 pounds
Material/Finish
Aluminum
BODY Copper-free aluminum
(less than 4/10 of 1%)
FINISH Electrostatically applied
powder coating
COVER (Aluminum)
Copper-free aluminum (less than
4/10 of 1%). Electrostatically
applied powder coating
Iron
BODY Duraloy iron alloy
FINISH Tri-Coat Finish of
Electrozinc, Chromate Sealant,
and electrostatically applied
powder coating
COVER (Aluminum)
Copper-free aluminum (less than
4/10 of 1%). Electrostatically
applied powder coating
Listed - File E30107 and E3397
Certified - File LR11852
See files for details or call Killark.
CATALOG NUMBER
SHALLOW MEDIUM DEEP CONDUIT HUB
1-5/8"(00) 2-1/4"(57) 3-5/8"(92) SIZE ARRANGEMENT
KILLARK DURALOY KILLARK DURALOY KILLARK
ALUM. IRON ALUM. IRON ALUM.
VLJSX-1 VLJSX-1M VLJX-1 VLJX-1M 1/2" x
VLJSX-2 VLJSX-2M VLJX-2 VLJX-2M VLJDX-2 3/4" x
––VLJX-3 VLJX-3M VLJDX-3 1" x
BOXES WITH LUGS
MAXIMUM VOLUME
SERIES CONDUIT SIZE CUBIC INCHES
Shallow 3/4" 17
Medium 1" 25
Deep 1-1/4" 45
BACK CONDUIT OPENINGS
Note: Must be drilled and tapped.
VJBC Blank Cover VJH-1 or VJH-2 Hub Cover VBNB Gasket
COVERS AND GASKETS
Note: Cover and gasket not included.
CATALOG HUB SIZE DEPTH
NUMBER DESCRIPTION
VJBC 1/4" Blank cover furnished with mounting screws. Gasket not included
VJH-1 1/2" 1" Hub cover furnished with mounting screws. Gasket not included
VJH-2 3/4" 1" Hub cover furnished with mounting screws. Gasket not included
VBNB ––Gasket Nitrile Butadiene
VLJSX Shallow VLJX Medium VLJDX Deep
VLJSX VLJX
VLJ Series
VLJDX
VJ Series
EY SERIES FITTINGS
SEALING FITTINGS
F44
FEATURES-SPECIFICATIONS
Application & Installation
Class I, Divisions 1 and 2
The purpose of seals in a Class I
hazardous location is to minimize the
passage of gases and vapors and
prevent the passage of flames from
one electrical installation to another
through the conduit system. Seals are
required to be installed within 18
inches on any conduit run entering
an enclosure which contains devices
that may produce arcs, sparks, or
high temperature. Where two enclosures
are connected by a run of conduit not
over 3 ft. long, a single seal located
at the center of the run is considered
satisfactory. Only explosionproof
unions, couplings, elbows, and con-
duit bodies similar to “L”, “T”, and “X”
type shall be permitted between the
sealing fitting and the enclosure.
Seals shall be located within 18 inches
of the enclosure or fitting on each
conduit run of 2 inch size or larger
entering an enclosure or fitting that
contains terminals, splices, or taps.
Each run of conduit from a hazardous
location to a nonhazardous location
should be sealed to minimize the
amount of gases and vapors commu-
nicated beyond the seal.
Class II, Divisions 1 and 2
Where a raceway provides communi-
cation between an enclosure which is
required to be dust-ignitionproof and
one which is not, suitable means shall
be provided to prevent the entrance
of dust into the dust-ignitionproof
enclosure through the raceway.
Schematic drawings illustrate the appli-
cation of sealing compound, fiber
dams, and installed seal with drain.
Class I, Div. 1 & 2, Groups A,B,C,D
Class I, Zone 1, Groups IIC, IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Considerations for selection seals:
Select the proper sealing fitting for
the hazardous gas/vapor involved;
i.e., Class I Groups A, B, C, or D.
Zone 1, Groups IIC, IIB, IIC
Select a sealing fitting for the proper
use in respect to mounting position.
This is particularly critical when the
conduit runs between hazardous and
nonhazardous areas. Some seals are
designed to be mounted in any posi-
tion; others are restricted to vertical
mounting.
Drains
Where there is a probability that liq-
uid or other condensed vapor may
be trapped within enclosures for
control equipment or at any point in
the raceway system, approved
means — such as installation of
drain seals — shall be provided to
prevent moisture accumulation.
For more complete data or special
applications, consult the code or
your local inspector.
Sealing compounds shall be
approved for the purpose and shall
not be affected by the surrounding
atmosphere or liquids, and shall not
have a melting point of less than
93°C. (200°F.).
In the complete seal, the minimum
thickness of the sealing compound
shall not be less than the trade size
of the conduit, and in no case less
than 5/8 inch.
Note: The amount of Killark sealing
compound and packing fiber
required for any seal is determined
by volume hub size and mounting
position of the seal. Refer to installa-
tion data table on page F49 for
specific amounts required.
Splices and taps shall not be made
in fittings intended only for sealing
with compound, nor shall other fit-
tings in which splices or taps are
made be filled with compound.
Killark sealing fittings are produced
with utmost care to insure a sub-
stantial margin of safety. Threads
are clean, deep, and snug. When
properly installed with Killark sealing
compound (SC Type) and Killark
non-asbestos fiber (PF Type) for the
dams, you can be sure your installa-
tion will provide more than adequate
safety.
EYS EYS with Nipple
(For Vertical or Horizontal Conduit)
EYD EYD with Nipple
(Drain/Seal for Vertical Conduit)
EY EY with Nipple
(For Vertical Conduit)
ENY ENY with Nipple
(For Vertical or Horizontal Conduit) ENY-2
(Fixture Hanger)
(See Page L146)
ENY/EYS SERIES FITTINGS
SEALING FITTINGS F45
FEATURES-SPECIFICATIONS
F
ENY SEALING FITTINGS
AB
TURNING
RADIUS
HUB
SIZE
ENY WITH NIPPLE
ENY Series EYS Series
Dimensions
ENY-3 ENY-3-T with Nipple
(For Vertical or Horizontal Conduit)
EYS-3 EYS-3-T with Nipple
(For Vertical or Horizontal Conduit)
DIMENSIONS
EYS SEALING FITTINGS
AB
TURNING
RADIUS
EYS-7M
EYS-8M
EYS-9M
EYS-0M
3-15/16"(100)
4-1/16"(103)
4-25/32"(121)
5-3/8"(137)
5-11/16"(144)
6-3/8"(162)
7-5/8"(194)
7-5/8"(194)
7-1/8"(181)
7-1/8"(181)
1-13/16"(46)
2-1/16"(52)
2-11/32"(60)
3"(76)
3-1/4"(83)
3-15/16"(100)
4-1/2"(114)
4-1/2"(114)
5-3/16"(132)
5-3/16"(132)
1-3/16"(30)
1-9/32"(33)
1-13/32"(36)
1-25/32"(45)
1-29/32"(48)
2-5/16"(59)
4-1/8"(105)
4-3/8"(111)
4-3/4"(121)
4-3/4"(121)
EYS-7TM
EYS-8TM
EYS-9TM
EYS-0TM
HUB
SIZE
CATALOG NUMBER
EYS WITH NIPPLE
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
EYS-1
EYS-2
EYS-3
EYS-4
EYS-5
EYS-6
EYS-7
EYS-8
EYS-9
EYS-0
DIMENSIONS
CATALOG NUMBER
ENY-1, 2, 3, 4, 5, 6
Class I, Div. 1 & 2, Groups A,B,C,D
Class I, Zone 1, Groups IIC, IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
EYS Series
Class I, Div. 1 & 2, Groups C,D
Class I, Zone 1, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Listed File No. E10514
Certified File No. LR11716
ENY-1-T
ENY-2-T
ENY-3-T
ENY-4-T
ENY-5-T
ENY-6-T
ENY-1M
ENY-2M
ENY-3M
ENY-4M
ENY-5M
ENY-6M
3-15/16"(100)
4-1/16"(103)
4-25/32"(121)
5-3/8"(137)
5-11/16"(144)
6-3/8"(162)
1-13/16"(46)
2-1/16"(52)
2-11/32"(60)
3"(76)
3-1/4"(83)
3-15/16"(100)
1-3/16"(30)
1-9/32"(33)
1-13/32"(36)
1-25/32"(45)
1-29/32"(48)
2-5/16"(59)
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
ENY-1
ENY-2
ENY-3
ENY-4
ENY-5
ENY-6
ENY-1TM
ENY-2TM
ENY-3TM
ENY-4TM
ENY-5TM
ENY-6TM
CATALOG NUMBER
CATALOG NUMBER
EYS-1-T
EYS-2-T
EYS-3-T
EYS-4-T
EYS-5-T
EYS-6-T
EYS-7-T
EYS-8-T
EYS-9-T
EYS-0-T
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Duraloy Iron
Tri-Coat Finish of electrozinc, chro-
mate sealant, and electrostatically
applied powder coating
KILLARK
ALUMINUM
DURALOY
IRON
KILLARK
ALUMINUM
DURALOY
IRON
KILLARK
ALUMINUM
DURALOY
IRON
KILLARK
ALUMINUM
DURALOY
IRON
See files for details or call Killark.
EY/EYD SERIES FITTINGS
SEALING FITTING
F46
FEATURES-SPECIFICATIONS
EYD-3 EYD-3-T with Nipple
(Drain/Seal for vertical conduit)
EY & EYD Series
Class I, Div. 1 & 2, Groups C,D
Class I, Zone 1, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Listed File No. E10514
Certified File No. LR11716
DIMENSIONS
EY SEALING FITTINGS
A B
TURNING
RADIUS
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
EY-1M
EY-2M
EY-3M
EY-4M
EY-5M
EY-6M
EY-7M
EY-8M
EY-9M
EY-0M
3-1/16"(78)
3-1/16"(78)
4-9/32"(109)
5-1/8"(130)
5-1/8"(130)
5-1/8"(230)
7"(178)
7"(178)
8-3/4"(222)
8-3/4"(222)
2-3/4"(70)
2-3/4"(70)
3-1/8"(79)
3-7/8"(98)
4-5/8"(117)
5-11/16"(144)
6-5/16"(160)
6-5/16"(160)
7-1/8"(181)
7-1/8"(181)
2-1/4"(57)
2-1/4"(57)
2-3/8"(60)
2-7/8"(73)
3-7/16"(87)
4-1/4"(108)
4-5/8"(117)
4-5/8"(117)
5-3/8"(138)
5-3/8"(138)
EY-1TM
EY-2TM
EY-3TM
EY-4TM
EY-5TM
EY-6TM
EY-7TM
EY-8TM
EY-9TM
EY-0TM
HUB
SIZE
EY WITH NIPPLE
DIMENSIONS
EYD SEALING FITTINGS
AB
TURNING
RADIUS
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
EYD-1M
EYD-2M
EYD-3M
EYD-4M
EYD-5M
EYD-6M
EYD-7M
EYD-8M
EYD-9M
EYD-0M
4-9/32"(109)
4-9/32"(109)
4-9/32"(109)
5-1/8"(130)
5-1/8"(130)
5-1/8"(130)
7"(178)
7"(178)
8-3/4"(122)
8-3/4"(122)
3-1/8"(79)
3-1/8"(79)
3-1/8"(79)
3-7/8"(98)
4-5/8"(117)
5-11/16"(144)
6-5/16"(160)
6-5/16"(160)
7-1/8"(181)
7-1/8"(181)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-7/8"(73)
3-7/16"(87)
4-1/4"(108)
4-5/8"(117)
4-5/8"(117)
5-3/8"(137)
5-3/8"(137)
EYD-1TM
EYD-2TM
EYD-3TM
EYD-4TM
EYD-5TM
EYD-6TM
EYD-7TM
EYD-8TM
EYD-9TM
EYD-0TM
HUB
SIZE
EYD WITH NIPPLE
EY Series EYD Series
Dimensions
EY-3 EY-3-T with Nipple
(For Vertical Conduit)
EYD-1-T
EYD-2-T
EYD-3-T
EYD-4-T
EYD-5-T
EYD-6-T
EYD-7-T
EYD-8-T
EYD-9-T
EYD-0-T
EYD-1
EYD-2
EYD-3
EYD-4
EYD-5
EYD-6
EYD-7
EYD-8
EYD-9
EYD-0
CATALOG NUMBER
CATALOG NUMBER
CATALOG NUMBER CATALOG NUMBER
EY-1
EY-2
EY-3
EY-4
EY-5
EY-6
EY-7
EY-8
EY-9
EY-0
EY-1-T
EY-2-T
EY-3-T
EY-4-T
EY-5-T
EY-6-T
EY-7-T
EY-8-T
EY-9-T
EY-0-T
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Duraloy Iron
Tri-Coat Finish of electrozinc,
chromate sealant, and electro-
statically applied powder coating
KILLARK
ALUMINUM
DURALOY
IRON
KILLARK
ALUMINUM
DURALOY
IRON
KILLARK
ALUMINUM
DURALOY
IRON
KILLARK
ALUMINUM
DURALOY
IRON
See files for details or call Killark.
ENY40/EYD40 SERIES FITTINGS
40% FILL SEALING FITTINGS F47
FEATURES-SPECIFICATIONS
F
ENY40-1, 2, 3, 4, 5
Class I, Div. 1 & 2, Groups B, C, D
Class I, Zone 1, Groups IIB+H2, IIA
Class II, Div. 1 & 2, Groups E, F, G
Class III
ENY40-6, 7, 8, 9, 0
EYD40(1 through 0) -6, 7, 8, 9, 0
Class I, Div. 1 & 2, Groups C, D
Class I, Zone 1, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E, F, G
Class III
Application
To seal Rigid Conduit or IMC
Raceways with up to 40% wire fill.
Features
A 40% wire fill capacity
Large openings with threaded clo-
sures to provide easy access to
conduit hubs for making dams
Integral bushing in conduit hubs
to protect conductor insulation
from damage
NPT threaded hubs to ensure
ground continuity
Minimum turning radius
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied powder
coating
Duraloy Iron
Tri-Coat Finish of electrozinc,
chromate sealant, and electrostati-
cally applied powder coating
ENY40 40% VERTICAL AND/OR HORIZONTAL CONDUIT SEALING FITTINGS
A B
TURNING
RADIUS*
HUB
SIZE
DIMENSIONS
CATALOG NUMBER
ENY40-1M
ENY40-2M
ENY40-3M
ENY40-4M
ENY40-5M
ENY40-6M
ENY40-7M
ENY40-8M
ENY40-9M
ENY40-0M
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
ENY40-1
ENY40-2
ENY40-3
ENY40-4
ENY40-5
ENY40-6
ENY40-7
ENY40-8
ENY40-9
ENY40-0
0.06
0.12
0.26
1.00
2.00
3.00
3.56
6.00
7.00
9.60
2
4
7
13
22
36
61
89
114
202
1-9/32"(33)
1-13/32"(36)
1-25/32"(45)
1-29/32"(48)
2-5/16"(59)
4-1/8"(105)
4-3/8"(111)
4-3/4"(121)
4-3/4"(121)
4-1/4"(108)
2-1/16"(52)
2-11/32"(60)
3"(76)
3-1/4"(83)
3-15/16"(100)
4-1/2"(114)
4-1/2"(114)
5-3/16"(132)
5-3/16"(132)
6-1/2"(165)
4-1/16"(103)
4-25/32"(121)
5-3/8"(137)
5-11/16"(144)
6-3/8"(162)
7-5/8"(194)
7-5/8"(194)
7-1/8"(181)
7-1/8"(181)
11-1/16"(281)
KILLARK
ALUMINUM
DURALOY
IRON
REQUIRED SEALING
COMPOUND &
PACKING FIBER OZ.
PER HUB
(PF)
EYD40 40% VERTICAL CONDUIT DRAIN SEALING FITTINGS
AB
TURNING
RADIUS*
HUB
SIZE
DIMENSIONS
CATALOG NUMBER
EYD40-1M
EYD40-2M
EYD40-3M
EYD40-4M
EYD40-5M
EYD40-6M
EYD40-7M
EYD40-8M
EYD40-9M
EYD40-0M
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1 /2"
3"
3-1 /2"
4"
EYD40-1
EYD40-2
EYD40-3
EYD40-4
EYD40-5
EYD40-6
EYD40-7
EYD40-8
EYD40-9
EYD40-0
0.03
0.06
0.13
0.50
1.00
1.50
1.75
3.00
3.50
4.50
4
6
7
13
22
36
61
89
114
202
2-1/4”(57)
2-1/4”(57)
2-7/8”(73)
3-7/16”(87)
4-1/4”(108)
4-5/8”(117)
4-5/8”(117)
5-3/8”(137)
5-3/8”(137)
4-1/4”(108)
3-1/8"(79)
3-1/8"(79)
3-7/8"(98)
4-5/8"(117)
5-11/16"(144)
6-5/16"(160)
6-5/16"(160)
7-1/8"(181)
7-1/8"(181)
6-1/2"(165)
4-9/32"(109)
4-9/32"(109)
5-1/8"(130)
5-1/8"(130)
5-1/8"(130)
7"(178)
7"(178)
8-3/4"(122)
8-3/4"(122)
11-1/16"(281)
KILLARK
ALUMINUM
DURALOY
IRON
REQUIRED SEALING
COMPOUND &
PACKING FIBER OZ.
PER HUB
(PF)
ENY
ENY40
EYD
A
B
Turning Radius
EYD40
A
B
Turning Radius
* Turning radius with cover plug removed.
ENY/EYS/EY/EYD SERIES FITTINGS
SEALING MATERIALS
F48
FEATURES-SPECIFICATIONS
SEALING COMPOUND
SEALING COMPOUND
THREAD LUBRICANTS
Sealing Compound Packing Fiber Thread Lubricants
Series SC/PF/LUBG
Sealing Materials
Sealing Compound
SC Series Sealing compound is a
cement used extensively for sealing
conduit to prevent the spread of
explosive gases. It is non-shrinking
and a secure seal is formed. SC
Series resists acids, water, oil, etc. It
is UL Listed for use with Killark ENY,
EY, and EYS Series. Also CSA certi-
fied for use with any CSA certified
sealing fitting.
Packing Fiber
Killark’s Packing Fiber is made from
an environmentally safe, non-
asbestos material. It is easy to use
and forms a positive dam to hold
compound (Killark SC Type) in ENY,
EY, and EYS Series fittings.
Thread Lubricants
Two special blends of lubricants
have been developed by Killark for
use with threaded joints. These
lubricants are to be used to prevent
galling of pipe threads when threaded
into a coupling, junction box, etc.
They insure a quick release of
undamaged male and female threads
when parts are disassembled.
LUBG is a general purpose lubricant
to be used in temperatures ranging
from 0° to 125°F.
LUBT is a high-quality lubricant to be
used in temperatures ranging from -
40° to +500°F. It is recommended to
be used on hazardous location light-
ing fixtures.
OUNCES REQUIRED PER FITTING
ENY1
HUB SIZE EYS1EY/EYD
PACKING FIBER
1.5 oz.
2.0 oz.
3.0 oz.
6.5 oz.
8.5 oz.
15.0 oz.
3.0 oz.
3.0 oz.
8.0 oz.
8.5 oz.
17.5 oz.
27.0 oz.
42.0 oz.
47.0 oz.
56.0 oz.
56.0 oz.
1.0 oz.
2.0 oz.
4.5 oz.
7.5 oz.
12.0 oz.
24.0 oz.
44.0 oz.
44.0 oz.
75.0 oz.
75.0 oz.
1/16 oz.
1/8 oz.
1/4 oz.
1/2 oz.
1 oz.
2 oz.
3 oz.
4 oz.
6 oz.
9 oz.
SIZE PACKAGE
CATALOG NUMBER
4 oz.
8 oz.
1 lb.
5 lbs.
SC-4 OZ
SC-8 OZ
SC-1 LB
SC-5 LB
PACKING FIBER
SIZE PACKAGE
CATALOG NUMBER
2 oz.
4 oz.
1 lb.
PF-2
PF-4
PF-16
CONTAINER PACKAGECATALOG NUMBER
2 oz.
6 oz.
LUBT-2
LUBG-6
1/2"
3/4"
1"
1-1/4"
1 1/2"
2"
2-1/2"
3"
3-1/2"
4"
1ENY/EYS suitable for both horizontal or vertical applications.
GEB FITTINGS
ALUMINUM OUTLET BODIES F49
FEATURES-SPECIFICATIONS
F
Listed File No. E 10514
Certified File No. LR11716
ATEX Consult Factory
Class I, Div. 1 & 2, Groups B, C, D*
Class I, Zone I, Groups IIC, IIB, IIA
Class II, Div. 1 & 2, Groups E, F, G
Class III
NEMA 4X
Applications
GEB series conduit boxes are
installed in conduit systems within
hazardous areas to:
Protect conductors in threaded
rigid conduit
Act as pull and splice boxes
Interconnect lengths of conduit
Change conduit direction
Provide access to conductors for
maintenance and future system
changes
Features
Suitable for NEMA 4X applications
Integral mounting lugs
Green ground screw standard
External cover thread on body plus
smooth integral hub bushing pro-
tects conductor insulation when
pulling
4 different hub arrangements
Taper threaded hubs provide
ground continuity
External threaded body for addi-
tional wiring room
Covers and gaskets furnished with
boxes as standard
Material/Finish
Aluminum
BODY & COVER Copper-free
aluminum
(less than 4/10 of 1%)
FINISH Electrostatically applied
powder coating
Size Ranges
Hub — 3/4" to 1-1/2"
Cover opening — 3-1/2
Applicable Third Party Standards
UL Standard: 886
CSA Standard: C22.2 No. 30
* 1-1/2" hub sizes require seal within
24" for Group B applicatons.
C TYPE OUTLET BODY
6-1/2"
(165)
6-1/2"
(165)
6-1/2"
(165)
6-1/2"
(165)
4-5/16"
(110)
4-5/16"
(110)
4-5/16"
(110)
4-5/16"
(110)
3-1/4"
(83)
3-1/4"
(83)
3-1/4"
(83)
3-1/4"
(83)
2-15/16"
(75)
2-15/16"
(75)
2-15/16"
(75)
2-15/16"
(75)
1-3/32"
(28)
1-3/32"
(28)
1-3/32"
(28)
1-3/32"
(28)
1-3/16"
(30)
1-3/16"
(30)
1-3/16"
(30)
1-3/16"
(30)
3-1/2"
(89)
3-1/2"
(89)
3-1/2"
(89)
3-1/2"
(89)
ABCDEF
COVER
OPENING
DIMENSIONS
CATALOG
NUMBER
HUB
SIZE
3/4"
1"
1-1/4"
1-1/2"
GEBC-2
GEBC-3
GEBC-4
GEBC-5
29
29
29
29
VOLUME
CU. IN.
L TYPE OUTLET BODY
5-1/2"
(140)
5-1/2"
(140)
5-1/2"
(140)
5-1/2"
(140)
4-5/16"
(110)
4-5/16"
(110)
4-5/16"
(110)
4-5/16"
(110)
3-1/4"
(83)
3-1/4"
(83)
3-1/4"
(83)
3-1/4"
(83)
2-15/16"
(75)
2-15/16"
(75)
2-15/16"
(75)
2-15/16"
(75)
1-3/32"
(28)
1-3/32"
(28)
1-3/32"
(28)
1-3/32"
(28)
1-3/16"
(30)
1-3/16"
(30)
1-3/16"
(30)
1-3/16"
(30)
3-1/2"
(89)
3-1/2"
(89)
3-1/2"
(89)
3-1/2"
(89)
ABCDEF
COVER
OPENING
DIMENSIONS
CATALOG
NUMBER
HUB
SIZE
3/4"
1"
1-1/4"
1-1/2"
GEBL-2
GEBL-3
GEBL-4
GEBL-5
29
29
29
29
VOLUME
CU. IN.
C Type L Type
C Type L Type
4-13/16
4-13/16
GEB FITTINGS
ALUMINUM OUTLET BODIES
F50
FEATURES-SPECIFICATIONS
Dimensions
Listed File No. E 10514
Certified File No. LR11716
ATEX Consult Factory
Class I, Div. 1 & 2, Groups B, C, D*
Class I, Zone I, Groups IIC, IIB, IIA
Class II, Div. 1 & 2, Groups E, F, G
Class III
NEMA 4X
T Type X Type
T TYPE OUTLET BODY
6-1/2"
(165)
6-1/2"
(165)
6-1/2"
(165)
6-1/2"
(165)
6 -1/2”
(165)
6 -1/2”
(165)
4-5/16"
(110)
4-5/16"
(110)
4-5/16"
(110)
4-5/16"
(110)
4 -5/16”
(110)
4 -5/16”
(110)
3-1/4"
(83)
3-1/4"
(83)
3-1/4"
(83)
3-1/4"
(83)
3 -1/4”
(83)
3 -1/4”
(83)
2-15/16"
(75)
2-15/16"
(75)
2-15/16"
(75)
2-15/16"
(75)
2 -15/16”
(75)
2 -15/16”
(75)
1-3/32"
(28)
1-3/32"
(28)
1-3/32"
(28)
1-3/32"
(28)
1 - 3/32”
(28)
1 - 3/32”
(28)
1-3/16"
(30)
1-3/16"
(30)
1-3/16"
(30)
1-3/16"
(30)
1 - 3/16”
(30)
1 - 3/16”
(30)
3-1/2"
(89)
3-1/2"
(89)
3-1/2"
(89)
3-1/2"
(89)
3 -1/2”
(89)
3 -1/2”
(89)
ABCDE F
COVER
OPENING
DIMENSIONS
CATALOG
NUMBER
HUB
SIZE
3/4"
1"
1-1/4"
1-1/2"
(2) 3/4”
(1) 1-1/4”
(2) 3/4”
(1) 1-1/2”
GEBT-2
GEBT-3
GEBT-4
GEBT-5
GEBT-24
GEBT-25
29
29
29
29
29
29
VOLUME
CU. IN.
X TYPE OUTLET BODY
6-1/2"
(165)
6-1/2"
(165)
6-1/2"
(165)
6-1/2"
(165)
4-5/16"
(110)
4-5/16"
(110)
4-5/16"
(110)
4-5/16"
(110)
3-1/4"
(83)
3-1/4"
(83)
3-1/4"
(83)
3-1/4"
(83)
2-15/16"
(75)
2-15/16"
(75)
2-15/16"
(75)
2-15/16"
(75)
1-3/32"
(28)
1-3/32"
(28)
1-3/32"
(28)
1-3/32"
(28)
1-3/16"
(30)
1-3/16"
(30)
1-3/16"
(30)
1-3/16"
(30)
3-1/2"
(89)
3-1/2"
(89)
3-1/2"
(89)
3-1/2"
(89)
ABCDEF
COVER
OPENING
DIMENSIONS
CATALOG
NUMBER
HUB
SIZE
3/4"
1"
1-1/4"
1-1/2"
GEBX-2
GEBX-3
GEBX-4
GEBX-5
29
29
29
29
VOLUME
CU. IN.
T Type X Type
*1-1/2” hub size requires seal within 24” for group B applications.
See page F49 for Standard Materials & Finish
Outlet Box for in-line
(multiple) stanchion mount fixtures
Typical Applications:
Coal Conveyors,Cat Walks,Platform Hand Rails
GEBT-25 with two 3/4” feed-thru hubs
and one 1-1/2” vertical hub
4-13/16”
4-13/16”
21/64”
GE SERIES FITTINGS
ALUMINUM AND IRON OUTLET BODIES F51
FEATURES-SPECIFICATIONS
F
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
COVER
OPENINGS
E TYPE OUTLET BODY*
3-11/16"
(94)
3-11/16"
(94)
3-11/16"
(94)
6-1/4"
(159)
3-5/8"
(92)
3-5/8"
(92)
3-5/8"
(92)
4-3/8"
(111)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
4-7/8"
(124)
2-3/4"
(70)
2-3/4"
(70)
2-3/4"
(70)
3-9/16"
(90)
1"
(25)
1"
(25)
1"
(25)
1-3/16"
(46)
13/16"
(21)
13/16"
(21)
1-1/8"
(21)
1-3/16"
(46)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
4-7/8"
(124)
18
18
19
75
GECET-1M
GECET-2M
GECET-3M
GEJET-5M
GECET-1
GECET-2
GECET-3
GEJET-5
1/2"
3/4"
1"
1-1/4"
1-1/2"
ABCDEF
DIMENSIONS
Listed File No. E 10514
Certified File No. LR11716
Applications
GE series conduit boxes are
installed in conduit systems within
hazardous areas to:
Protect conductors in threaded
rigid conduit
Act as pull and splice boxes
Interconnect lengths of conduit
Change conduit direction
Provide access to conductors for
maintenance and future system
changes
Features
GE conduit outlet boxes have:
GEM, GEC and GES have water
shedding cover — suitable for wet
locations when mounted in upright
position
External cover threads on body
protecting conductors from dam-
age during pulling
No pinching of conductors during
cover installation
Ten different hub arrangements
Taper threaded hubs to provide
ground continuity
Smooth integral hub bushing to
protect conductor insulation when
pulling
Internally threaded cover openings
for additional wiring room
Covers furnished with boxes
Weather-resistant finish
Green ground screw standard in
all boxes
1/2", 3/4" and 1" Bodies
Class I, Div. 1 & 2, Groups C & D
Class I, Zone 1, Groups IIB, IIA
• 1-1/4", 1-1/2", and 2" Bodies
Class I,Div. 1 & 2, Group D
Class I, Zone 1, Group IIA
• All Bodies
Class II and Class III
For GEJ Series CSA applications
for Class I Group C, seal conduit
within 18 inches
GEC Type
Dimensions
KILLARK
ALUM.
DURALOY
IRON
Material/Finish
Aluminum
BODY Copper-free aluminum
(less than 4/10 of 1%)
FINISH Electrostatically applied
powder coating
COVER (Aluminum)
Copper-free aluminum (less than
4/10 of 1%). Electrostatically
applied powder coating
Iron
BODY Duraloy iron alloy
FINISH Tri-coat finish of electroz-
inc, chromate sealant, and electro-
statically applied powder coating
COVER (Aluminum)
Copper-free aluminum (less than
4/10 of 1%). Electrostatically
applied powder coating
Size Ranges
Hub — 1/2" to 2"
Cover opening — 2-1/16" to
4-7/8" diameter
Applicable Third Party Standards
UL Standard: 886
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
GEJ
E Type
* For GROUP B applications, contact factory.
GEC
E Type
E Type
GE SERIES FITTINGS
ALUMINUM AND IRON OUTLET BODIES
F52
FEATURES-SPECIFICATIONS
Dimensions
VOLUME
CU. IN.
COVER
OPENINGS
C TYPE OUTLET BODY*
2-13/16"
(71)
2-13/16"
(71)
3-11/16"
(94)
3-11/16"
(94)
3-11/16"
(94)
5-1/16"
(128)
5-1/16"
(128)
6-1/4"
(159)
6-1/4"
(159)
3"
(76)
3"
(76)
3-5/8"
(92)
3-5/8"
(92)
3-5/8"
(92)
4-1/8"
(105)
4-1/8"
(105)
4-3/8"
(111)
4-3/8"
(111)
2-1/16"
(52)
2-1/16"
(52)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
3-9/16"
(90)
3-9/16"
(90)
4-7/8"
(124)
4-7/8"
(124)
2-5/16"
(79)
2-5/16"
(79)
2-3/4"
(70)
2-3/4"
(70)
2-3/4"
(70)
3-7/16"
(87)
3-7/16"
(87)
3-9/16"
(90)
3-9/16"
(90)
11/16"
(17)
11/16"
(17)
1"
(25)
1"
(25)
1"
(25)
1-1/16"
(27)
1-1/16"
(27)
1-3/16"
(30)
1-1/2"
(38)
13/16"
(21)
13/16"
(21)
13/16"
(21)
13/16"
(21)
1-1/8"
(28)
1-1/8"
(28)
1-3/16"
(30)
1-3/16"
(30)
1-3/16"
(30)
2-1/16"
(52)
2-1/16"
(52)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
3-9/16"
(90)
3-9/16"
(90)
4-7/8"
(124)
4-7/8"
(124)
8
8
18
18
19
42
42
75
75
GECCT-1M
GECCT-2M
GECCT-3M
GESCT-3M
GESCT-4M
GEJCT-5M
GEJCT-6M
GEMC-1
GEMC-2
GECCT-1
GECCT-2
GECCT-3
GESCT-3
GESCT-4
GEJCT-5
GEJCT-6
1/2"
3/4"
1/2"
3/4"
1"
1"
1-1/4"
1-1/2"
2"
ABCDEF
DIMENSIONS
Listed File No. E 10514
Certified File No. LR11716
1/2", 3/4" and 1" Bodies
Class I, Div. 1 & 2, Groups C,D
Class I, Zone 1, Groups IIB, IIA
• 1-1/4", 1-1/2", and 2" Bodies
Class I, Div. 1 & 2, Group D
Class I, Zone 1, Group IIA
• All Bodies
Class II and Class III
For GEJ Series CSA applications
for Class I Group C, seal conduit
within 18 inches
GES
C Type
GEM
L Type
See page F51 for Standard Materials & Finish
C Type
L Type
Applicable Third Party Standards
UL Standard: 886
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
L TYPE OUTLET BODY*
2-13/16"
(71)
2-13/16"
(71)
3-11/16"
(94)
3-11/16"
(94)
3-11/16"
(94)
5-1/16"
(128)
5-1/16"
(128)
6-1/4"
(159)
6-1/4"
(159)
3"
(76)
3"
(76)
3-5/8"
(92)
3-5/8"
(92)
3-5/8"
(92)
4-1/8"
(105)
4-1/8"
(105)
4-3/8"
(111)
4-3/8"
(111)
2-1/16"
(52)
2-1/16"
(52)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
3-9/16"
(90)
3-9/16"
(90)
4-7/8"
(124)
4-7/8"
(124)
2-5/16"
(79)
2-5/16"
(79)
2-3/4"
(70)
2-3/4"
(70)
2-3/4"
(70)
3-7/16"
(87)
3-7/16"
(87)
3-9/16"
(87)
3-9/16"
(87)
11/16"
(17)
11/16"
(17)
1"
(25)
1"
(25)
1"
(25)
1-1/16"
(27)
1-1/16"
(27)
1-3/16"
(30)
1-1/2"
(38)
13/16"
(21)
13/16"
(21)
13/16"
(21)
13/16"
(21)
13/16"
(28)
1-1/8"
(28)
1-3/16"
(30)
1-3/16"
(30)
1-3/16"
(30)
2-1/16"
(52)
2-1/16"
(52)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
3-9/16"
(90)
3-9/16"
(90)
4-7/8"
(124)
4-7/8"
(124)
8
8
18
18
18
42
42
75
75
GECLT-1M
GECLT-2M
GECLT-3M
GESLT-3M
GESLT-4M
GEJLT-5M
GEJLT-6M
GEML-1
GEML-2
GECLT-1
GECLT-2
GECLT-3
GESLT-3
GESLT-4
GEJLT-5
GEJLT-6
1/2"
3/4"
1/2"
3/4"
1"
1"
1-1/4"
1-1/2"
2"
CATALOG NUMBER HUB
SIZE
KILLARK
ALUM.
DURALOY
IRON
* For GROUP B applications, contact factory.
GE SERIES FITTINGS
ALUMINUM AND IRON OUTLET BODIES F53
F
FEATURES-SPECIFICATIONS
See page F51 for Standard Materials & Finish
Applicable Third Party Standards
UL Standard: 886
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
T Type
X Type
LB Type
GES
X Type
GEJ
LB Type
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
COVER
OPENINGS
T TYPE OUTLET BODY*
2-13/16"
(56)
2-13/16"
(56)
3-11/16"
(93)
3-11/16"
(93)
3-11/16"
(93)
5-1/16"
(129)
5-1/16"
(129)
6-1/4"
(159)
6-1/4"
(159)
3"
(76)
3"
(76)
3-5/8"
(92)
3-5/8"
(92)
3-5/8"
(92)
4-1/8"
(105)
4-1/8"
(105)
4-3/8"
(111)
4-3/8"
(111)
2-1/16"
(52)
2-1/16"
(52)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
3-9/16"
(90)
3-9/16"
(90)
4-7/8"
(124)
4-7/8"
(124)
2-5/16
(59)
2-5/16
(59)
2-3/4"
(70)
2-3/4"
(70)
2-3/4"
(70)
3-7/16"
(87)
3-7/16"
(87)
3-9/16"
(90)
3-9/16"
(90)
11/16"
(17)
11/16"
(17)
1"
(25)
1"
(25)
1"
(25)
1-1/16"
(27)
1-1/16"
(27)
1-3/16"
(30)
1-1/2"
(38)
13/16"
(21)
13/16"
(21)
13/16"
(21)
13/16"
(21)
13/16"
(21)
1-1/8"
(29)
1-1/8"
(29)
1-3/16"
(30)
1-3/16"
(30)
2-1/16"
(52)
2-1/16"
(52)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
3-9/16"
(90)
3-9/16"
(90)
4-7/8"
(124)
4-7/8"
(124)
8
8
19
19
19
42
42
75
75
GECTT-1M
GECTT-2M
GECTT-3M
GESTT-3M
GESTT-4M
GEJTT-5M
GEJTT-6M
GEMT-1
GEMT-2
GECTT-1
GECTT-2
GECTT-3
GESTT-3
GESTT-4
GEJTT-5
GEJTT-6
ABCDEF
DIMENSIONS
X TYPE OUTLET BODY*
2-13/16"
(56)
2-13/16"
(56)
3-11/16"
(93)
3-11/16"
(93)
3-11/16"
(93)
5-1/16"
(129)
5-1/16"
(129)
6-1/4"
(159)
6-1/4"
(159)
3"
(76)
3"
(76)
3-5/8"
(92)
3-5/8"
(92)
3-5/8"
(92)
4-1/8"
(105)
4-1/8"
(105)
4-3/8"
(111)
4-3/8"
(111)
2-1/16"
(52)
2-1/16"
(52)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
3-9/16"
(90)
3-9/16"
(90)
4-7/8"
(124)
4-7/8"
(124)
2-5/16
(59)
2-5/16
(59)
2-3/4"
(70)
2-3/4"
(70)
2-3/4"
(70)
3-7/16"
(87)
3-7/16"
(87)
3-9/16"
(90)
3-9/16"
(90)
11/16"
(17)
11/16"
(17)
1"
(25)
1"
(25)
1"
(25)
1-1/16"
(27)
1-1/16"
(27)
1-1/2"
(38)
1-1/2"
(38)
13/16"
(21)
13/16"
(21)
13/16"
(21)
13/16"
(21)
13/16"
(21)
1-1/8"
(29)
1-1/8"
(29)
1-3/16"
(30)
1-3/16"
(30)
2-1/16"
(52)
2-1/16"
(52)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
3-9/16"
(90)
3-9/16"
(90)
4-7/8"
(124)
4-7/8"
(124)
8
8
19
19
19
42
42
75
75
GECXT-1M
GECXT-2M
GECXT-3M
GESXT-3M
GESXT-4M
GEJXT-5M
GEJXT-6M
GEMX-1
GEMX-2
GECXT-1
GECXT-2
GECXT-3
GESXT-3
GESXT-4
GEJXT-5
GEJXT-6
LB TYPE OUTLET BODY*
2-13/16"
(56)
2-13/16"
(56)
3-11/16"
(93)
3-11/16"
(93)
3-11/16"
(93)
5-1/16"
(129)
5-1/16"
(129)
6-1/4"
(159)
6-1/4"
(159)
3"
(76)
3"
(76)
3-5/8"
(92)
3-5/8"
(92)
3-5/8"
(92)
4-1/8"
(105)
4-1/8"
(105)
4-3/8"
(111)
4-3/8"
(111)
2-1/16"
(52)
2-1/16"
(52)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
3-9/16"
(90)
3-9/16"
(90)
4-7/8"
(124)
4-7/8"
(124)
2-5/16
(59)
2-5/16
(59)
2-3/4"
(70)
2-3/4"
(70)
2-3/4"
(70)
3-7/16"
(87)
3-7/16"
(87)
3-9/16"
(90)
3-9/16"
(90)
11/16"
(17)
11/16"
(17)
1"
(25)
1"
(25)
1"
(25)
1-1/16"
(27)
1-1/16"
(27)
1-1/2"
(38)
1-1/2"
(38)
13/16"
(21)
13/16"
(21)
13/16"
(21)
13/16"
(21)
13/16"
(21)
1-1/8"
(29)
1-1/8"
(29)
1-3/16"
(30)
1-3/16"
(30)
2-1/16"
(52)
2-1/16"
(52)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
3-9/16"
(90)
3-9/16"
(90)
4-7/8"
(124)
4-7/8"
(124)
8
8
19
19
19
42
42
75
75
GECLBT-1M
GECLBT-2M
GECLBT-3M
GESLBT-3M
GESLBT-4M
GEJLBT-5M
GEJLBT-6M
GEMLB-1
GEMLB-2
GECLBT-1
GECLBT-2
GECLBT-3
GESLBT-3
GESLBT-4
GEJLBT-5
GEJLBT-6
Dimensions
Listed File No. E 10514
Certified File No. LR11716
1/2", 3/4" and 1" Bodies
Class I, Div. 1 & 2, Groups C,D
Class I, Zone 1, Groups IIB, IIA
• 1-1/4", 1-1/2", and 2" Bodies
Class I, Div. 1 & 2, Group D
Class I, Zone 1, Group IIA
• All Bodies
Class II and Class III
For GEJ Series CSA applications
for Class I Group C, seal conduit
within 18 inches
1/2"
3/4"
1/2"
3/4"
1"
1"
1-1/4"
1-1/2"
2"
1/2"
3/4"
1/2"
3/4"
1"
1"
1-1/4"
1-1/2"
2"
1/2"
3/4"
1/2"
3/4"
1"
1"
1-1/4"
1-1/2"
2"
KILLARK
ALUM.
DURALOY
IRON
GEC
T Type
* For GROUP B applications, contact factory.
GE SERIES FITTINGS
ALUMINUM AND IRON OUTLET BODIES
F54
FEATURES-SPECIFICATIONS
GEM
TA Type
See page F51 for Standard Materials & Finish
Applicable Third Party Standards
UL Standard: 886
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
Dimensions
TAT Type XAT Type
CAT Type EAT Type
TAT TYPE OUTLET BODY*
2-13/16"
(56)
3"
(76)
2-1/16"
(52)
2-5/16"
(59)
11/16"
(17)
13/16"
(21)
2-1/16"
(52) 8
GECTAT-2M
GEMTA-1
GEMTA-2
GECTAT-2
1/2"
3/4"
3/4"
CAT TYPE OUTLET BODY*
2-13/16"
(56)
2-13/16"
(56)
3"
(76)
3"
(76)
2-1/16"
(52)
2-1/16"
(52)
2-5/16"
(59)
2-5/16"
(59)
11/16"
(17)
11/16"
(17)
13/16"
(21)
1-3/16"
(30)
2-1/16"
(52)
2-1/16"
(52)
8
8
GEMCA-1
GEMCA-2
1/2"
3/4"
1/2"
1-1/4" 5-11/16
(144)
4-1/8"
(105)
3-9/16"
(90)
3-7/16"
(87)
1-1/16"
(27)
1-3/16"
(30)
3-9/16"
(90) 42
GESCAT-4M
GESCAT-4
3-11/16
(94)
3-5/8"
(92)
2-11/16"
(68)
2-3/4"
(70)
1"
(25)
13/16"
(21)
2-11/16"
(68) 19
GECCAT-1M
GECCAT-1
EAT TYPE OUTLET BODY*
3-11/16"
(94)
3-5/8"
(92)
2-11/16"
(68)
2-3/4"
(70)
1"
(25)
13/16"
(21)
2-11/16"
(68) 19
GECEAT-2M
GECEAT-2 3/4"
XAT TYPE OUTLET BODY*
3-11/16"
(94)
3-11/16"
(94)
3-11/16"
(94)
5-1/16"
(128)
3-5/8"
(92)
3-5/8"
(92)
3-5/8"
(92)
4-1/8"
(105)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
3-9/16"
(90)
2-3/4"
(70)
2-3/4"
(70)
2-3/4"
(70)
3-7/16"
(87)
1"
(25)
1"
(25)
1"
(25)
1-1/16"
(27)
13/16"
(21)
13/16"
(21)
13/16"
(21)
1-3/16"
(30)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
3-9/16"
(90)
19
19
19
42
GECXAT-1M
GECXAT-2M
GECXAT-3M
GESXAT-4M
GECXAT-1
GECXAT-2
GECXAT-3
GESXAT-4
1/2"
3/4"
1"
1-1/4"
Listed File No. E 10514
Certified File No. LR11716
1/2", 3/4" and 1" Bodies
Class I, Div. 1 & 2, Groups C,D
Class I, Zone 1, Groups IIB, IIA
1-1/4", 1-1/2", and 2" Bodies —
Class I, Div. 1 & 2, Group D
Class I, Zone 1, Group IIA
All Bodies —
Class II and Class III
For GEJ Series CSA applications
for Class I Group C, seal conduit
within 18 inches
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
COVER
OPENINGS
LA TYPE OUTLET BODY*
2-13/16"
(56)
3"
(76)
2-1/16"
(52)
2-5/16"
(59)
11/16"
(17)
13/16"
(21)
2-1/16"
(52) 8
GEMLA-1 1/2"
2-13/16"
(56)
3"
(76)
2-1/16"
(52)
2-5/16"
(59)
11/16"
(17)
13/16"
(21)
2-1/16"
(52) 8
GEMLA-2 3/4"
ABCDEF
DIMENSIONS
2-13/16"
(56)
3"
(76)
2-1/16"
(52)
2-5/16"
(59)
11/16"
(17)
13/16"
(21)
2-1/16"
(52) 8
3-11/16"
(94)
3-5/8"
(92)
2-11/16"
(68)
2-3/4"
(70)
1"
(25)
13/16"
(21)
2-11/16"
(68) 19
KILLARK
ALUM.
DURALOY
IRON
GEM
CA Type
GESXAT
XA Type
GEM
LA Type
GEC
EAT Type
* For GROUP B applications, contact factory.
GEC SERIES FITTINGS
OUTLET BODIES WITH MOUNTING FLANGE F55
FEATURES-SPECIFICATIONS
F
See page F51 for Standard Materials & Features
Applicable Third Party Standards
UL Standard: 886
CSA Standard: C22.2 No. 30
Fed Spec: W-C-586D
Mil Spec: F-28675
Listed File No. E 10514
Certified File No. LR11716
•1/2", 3/4" and 1" Bodies
Class I, Div. 1 & 2, Groups C,D
Class I, Zone 1, Groups IIB, IIA
Material/Finish
Aluminum
BODY Copper-free aluminum
(less than 4/10 of 1%)
FINISH Electrostatically applied
powder coating
COVER (Aluminum)
Copper-free aluminum (less than
4/10 of 1%). Electrostatically
applied powder coating
Iron
BODY Duraloy iron alloy
FINISH Tri-Coat Finish of
Electrozinc, Chromate Sealant,
and electrostatically applied
powder coating
COVER (Aluminum)
Copper-free aluminum (less than
4/10 of 1%). Electrostatically
applied powder coating
Size Ranges:
Hub — 3/4" standard
optional 1/2 to 1
contact factory
Cover opening — 2-11/16" or
2-1/16”
GECXTF
XTF Type Outlet Body
With Mounting Flange
XTF Type
With Mounting Flange
HUB
SIZE
CATALOG NUMBER VOLUME
CU. IN.
COVER
OPENINGS
XTF TYPE OUTLET BODY*
3-11/16"
(94)
3-11/16"
(94)
3-11/16"
(94)
3-5/8"
(92)
3-5/8"
(92)
3-5/8"
(92)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
2-3/4"
(70)
2-3/4"
(70)
2-3/4"
(70)
1"
(25)
1"
(25)
1"
(25)
13/16"
(21)
13/16"
(21)
13/16"
(21)
2-11/16"
(68)
2-11/16"
(68)
2-11/16"
(68)
19
19
19
GECXTF-1M
GECXTF-2M
GECXTF-3M
GECXTF-1
GECXTF-2
GECXTF-3
1/2"
3/4"
1"
ABCDEF
DIMENSIONS
KILLARK
ALUM.
DURALOY
IRON
GECUET-2
Outlet Body
GEUEAT-2
Outlet Body
GECUWT-2
Outlet Body
GECUET-2
Outlet Body
GEUEAT-2
Outlet Body
GECUWT-2
Outlet Body
GE TYPE OUTLET BODY*
3-11/16"
(94)
2-13/16"
(56)
3-11/16"
(94)
3-5/8"
(92)
3"
(76)
3-5/8"
(92)
2-11/16"
(68)
2-1/16"
(52)
2-11/16"
(68)
2-3/4"
(70)
2-1/8"
(54)
2-3/4"
(70)
1"
(25)
1"
(25)
1"
(25)
13/16"
(21)
13/16"
(21)
13/16"
(21)
2-11/16"
(68)
2-1/16"
(52)
2-11/16"
(68)
19
11
19
GECUET-2M
GEUEAT-2M
GECUWT-2M
GECUET-2
GEUEAT-2
GECUWT-2
3/4"
3/4"
3/4"
4-1/2”
4-7/16”
* For GROUP B applications, contact factory.
GE SERIES FITTINGS
OUTLET BODIES ACCESSORIES
F56
FEATURES-SPECIFICATIONS
SEALING COVER
Sealing cover used to convert body
into sealing fitting
Material/Finish
Copper-free aluminum
(less than 4/10 of 1%)
Electrostatically applied powder
coating
Blank covers are supplied standard
on all GE Series bodies
Dome covers provide additional
wiring room for splicing or accom-
modating components
Rubber gasket fits between cover
and body to make assembly
watertight
Complies with NEMA 4
Clear cover lens for viewing
CATALOG NUMBER SERIES
BLANK COVER
GEMBC
GECBC*
GESBC
GRM-BC
GEM
GEC
GES
GEJ
CATALOG NUMBER SERIES
DOME COVER
2GOU
4GOU
3GRMD
5GRMD
GEC
GEC
GEJ
GEJ
VOLUME CUBIC INCH
13.3
47.0
55.0
80.0
CATALOG NUMBER SERIES
GASKET
GEM-RG
GEC-RG
GES-RG
GRM-RG
GEM
GEC
GES
GEJ
CATALOG NUMBER SERIES
GEMEY1
GECEY1
GESEY1
GEJEY1
GEM
GEC
GES
GEJ
CATALOG NUMBER SERIES
LENS COVER
GL-375 GEJ
GRM-BC
Blank Cover
4GOU
Dome Cover
GEC-RG
Gasket
GL-375
Lens Cover
GECEY
Sealing Cover
1Sealing Covers CSA only.
Since all Series GE boxes are listed with a blank cover, deduct the price of blank cover and add the
price of the desired cover. Outlet bodies listed on preceding page.
* Available also in iron GECBCM
GR SERIES FITTINGS
OUTLET BODIES F57
FEATURES-SPECIFICATIONS
F
Listed - File E10514
Certified - File LR11716
See files for details or call Killark.
GRR
Features
Cast conduit hubs with integral
bushings
Blank cover included
Replacement cover
catalog number GRRBC
Compact size
Supplied with five hubs and three
close-up plugs
Material/Finish
Copper-free aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Class I, Div. 1 & 2, Groups C,D
Class II, Div. 1 & 2, Groups E,F,G
Class III
CATALOG NUMBER HUB SIZE
GRR-1 1/2"
GRR-2 3/4"
GRR-3 1"
Blank Cover-only-GRRBC
GRR W/BLANK COVER
GRSA
Features
Cast conduit hubs with integral
bushings
Cover included
Replacement cover catalog
number GECBC
Five close-up plugs included
Sealing, hub, dome covers and
gaskets available (page F56)
Material/Finish
Copper-free aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
GRSA GRR
Dimensions
GRR 1 & 2 GRR-3
CATALOG
NUMBER HUBS
Furnished with eight 3/4"
GRSA hubs including one 3/4" flush
hub in back center
GRSA W/BLANK COVER
VOLUME
CU. IN.
26.5
VOLUME
CU. IN.
13.0
13.0
14.0
CATALOG NUMBER
GEC-RG
GASKET (RUBBER)
CATALOG NUMBER
GRCEX-0
* Adds 2-7/8" to body
depth and
16.48 cu. in.
EXTENSION*
GR SERIES FITTINGS
OUTLET BODIES
F58
FEATURES-SPECIFICATIONS
Listed - File E10514
Certified - File LR11716
See files for details or call Killark.
Class I, Div. 1 & 2, Groups C,D
Class II, Div. 1 & 2, Groups E,F,G
Class III
GRSSA Dimensions
GRSS Dimensions
GRSSA
GRSS
CLOSE-UP
PLUGS
FURNISHED
VOLUME
CU. IN.
COVER
OPENINGS
GRSS/GRSSA DIMENSIONS
GRSS-1
GRSS-2
GRSS-3
GRSSA-1
GRSSA-2
1/2"
3/4"
1"
1/2"
3/4"
7
7
7
13
13
3-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
3-1/2"
2-3/8"
2-3/8"
2-3/8"
2-3/8"
2-3/8"
2-1/8"
2-1/8"
2-1/8"
2-1/8"
2-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
3-1/8"
29
29
29
20
20
1-3/16"
1-3/16"
1-3/16"
1-3/16"
1-3/16"
4-5/8"
4-5/8"
4-5/8"
4-5/8"
4-5/8"
N/A
N/A
N/A
2-1/8"
2-1/8"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
4
4
4
5
5
ABC DE FG H
DIMENSIONS IN INCHES
CATALOG
NUMBER
NO. OF
OPENINGS
HUB
SIZE
GRSS/GRSSA
Features
Internal hubs
Blank cover included
(Cat. No. GRRBC)
Compact design and multiple hub
configurations
Furnished with internal ground screw
Cast-in brackets on cover for use with
breaker-bar tools
GRSS Type
Furnished with seven internal hubs, two
hubs are on the top and bottom, one
each on the two sides and one hub in
the back. Four close-up plugs supplied.
Series GUM unions can be used.
Note: for mounting lugs on GRSS
series, contact factory.
GRSSA Type
Furnished with 13 hubs, two on each
side and five in back. Five close-up
plugs are supplied.
Material/Finish - Aluminum Body
Copper-free aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Material/Finish - Duraloy Iron Body
Duraloy iron alloy
Tri-Coat finish of Electrozinc,
Chromate Sealant and electrostatical-
ly applied powder coating
Material/Finish - GR Series Cover
Copper-free aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
NUMBER OF
NUMBER CLOSE-UP
KILLARK DURALOY HUB OF PLUGS
ALUM. IRON SIZE OPENINGS FURNISHED
GRSS-1 GRSS-1M 1/2" 74
GRSS-2 GRSS-2M 3/4" 74
GRSS-3 GRSS-3M 1 " 74
GRSSA-1 – 1/2" 13 5
GRSSA-2 – 3/4" 13 5
GRSS/GRSSA
CATALOG NUMBER
CATALOG NUMBER
GEC-RG
GASKET (RUBBER)
CATALOG NUMBER
GRCEX-0
* Adds 2-7/8" to body
depth and 16.48 cu. in.
EXTENSION*
X/XALB SERIES FITTINGS
CONDUIT BODIES F59
FEATURES-SPECIFICATIONS
F
X
Features
Integral bushings
Easy access covers
Six hub styles
Sizes 1/2", 3/4", 1"
Material/Finish
Copper-free aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
Listed - File E10514
Certified - File LR11716
See files for details or call Killark.
X Series
Class I, Div. 1 & 2, Groups C,D
Class II, Div. 1 & 2, Groups E,F,G
Class III
X DIMENSIONS
1X Series 1" hub size suitable for
Class I, Group D
XALB
Applications
Designed to permit straight pulls of
heavy cable.
Features
Integral bushings
Easy access covers
Sizes 1-1/4" thru 3"
CATALOG NUMBER HUB SIZE VOLUME CU.IN.
XALB-4 1-1/4" 27
XALB-5 1-1/2" 27
XALB-6 2" 70
XALB-7 2-1/2" >100
XALB-8 3" >100
XALB Series suitable for Class 1, Group D only.
XALB CONDUIT BODIES
XALB Series
Class I, Div. 1 & 2, Group D
Class II, Div. 1 & 2, Groups E,F,G
Class III
AB
CONDUIT OVERALL LENGTH WIDTH
SIZE DEPTH OF BODY OF BODY
1-1/4" 4-1/16"(103) 7-3/4"(197) 3-15/16"(100)
1-1/2" 4-1/16"(103) 7-3/4"(197) 3-15/16"(100)
2" 5-7/8"(149) 11-1/8"(282) 4-3/4"(121)
2-1/2" 8-1/4"(209) 17-1/2"(444) 6-7/16"(163)
3" 8-1/4"(209) 17-1/2"(444) 6-7/16"(163)
XALB DIMENSIONS
XT-2
XLR-2
XALB
XLRT-21
XLL-2
A
LENGTH
5-9/16"
5-13/16"
6-1/16"
4-5/8"
4-29/32"
5-9/16"
4-5/8"
4-29/32"
5-17/32
4-5/8"
4-29/32"
5-9/16"
5-9/16"
5-13/16"
6-11/16"
5-3/4"
5-3/4"
B
WIDTH
1-17/32"
1-3/4"
2-3/8"
2-7/16"
2-5/8"
3-1/2"
1-17/32"
1-3/4"
2-3/8"
2-7/16"
2-5/8"
3-1/2"
2-7/16"
2-5/8"
3-1/2"
2-21/32"
2-21/32"
C
HEIGHT
2-1/8"
2-1/4"
2-1/2"
2-1/8"
2-1/4"
2-1/2"
2-15/16"
3-1/8"
3-5/8"
2-1/8"
2-1/4"
2-1/2"
2-1/8"
2-1/4"
2-1/2"
2-1/2"
2-1/2"
D
5/8"
11/16"
7/8"
5/8"
11/16"
7/8"
5/8"
11/16"
7/8"
5/8"
11/16"
7/8"
5/8"
11/16"
7/8"
11/16"
11/16"
E
3/4"
7/8"
7/8"
3/4"
11/16"
7/8"
3/4"
7/8"
7/8"
VOLUME
CU. IN.
4.3
6.5
11.5
4.3
6.5
11.5
4.3
6.5
11.5
4.3
6.5
11.5
4.3
6.5
11.5
7
7
CATALOG HUB
NUMBER SIZE
XC-1 1/2"
XC-2 3/4"
XC-3 1"1
XLL-1 1/2"
XLL-2 3/4"
XLL-3 1"1
XLB-1 1/2"
XLB-2 3/4"
XLB-3 1"1
XLR-1 1/2"
XLR-2 3/4"
XLR-3 1"1
XT-1 1/2"
XT-2 3/4"
XT-3 1"1
XLRT-2 1 3/4" Ends
1/2" Side
XLRT-2 2 3/4" End
3/4" Side
Material/Finish
Copper-free aluminum
(less than 4/10 of 1%)
Electrostatically applied
powder coating
AC
B
D
AC
B
D
AC
B
AC
B
D
D
E
AC
B
D
AC
B
D
E
1X Series 1”hub size suitable for Class 1, Group D
JAL OUTLET BODIES WITH COVER
JL OUTLET BODIES WITH COVER
JL/JAL SERIES FITTINGS
OUTLET BODIES
F60
FEATURES-SPECIFICATIONS
Listed - File E10514
Certified - File LR11716
See files for details or call Killark.
Class I, Div. 1 & 2, Groups C,D
Class II, Div. 1 & 2, Groups E,F,G
Class III
REPLACEMENT BLANK COVER
Applications
To provide access to conductors for
pulling, splicing, and maintenance.
May be used as a fixture hanger.
Features
Option of blank or hub covers
Cast mounting lugs
Large wiring area
Furnished with internal ground
screw
Hub covers include set screws for
locking to lighting fixture stems
JL - Cast external hubs with inte-
gral bushings
JAL - Four drilled and tapped con-
duit openings in an “x” configura-
tion (three, close-up plugs included
to allow five variations from one
body)
Option of blank or hub covers
Material/Finish
Copper-free aluminum
(less than 4/10 of 1%)
Natural Finish
1To order box only omit last digit of catalog number.
CATALOG NUMBER
WITH BLANK WITH HUB
COVER COVER
JLC-10 JLC-11
— JLC-12
JLC-20 JLC-21
— JLC-22
JLX-10 JLX-11
— JLX-12
JLX-20 JLX-21
— JLX-22
CONDUIT SIZE
BOX1COVER
1/2" 1/2"
1/2" 3/4"
3/4" 1/2"
3/4" 3/4"
1/2" 1/2"
1/2" 3/4"
3/4" 1/2"
3/4" 3/4"
BOX
TYPE
1To order box only omit last digit of catalog number. 21-1/4" for Class I, Group D.
CATALOG NUMBER
WITH BLANK WITH HUB
COVER COVER
JALX-10 JALX-11
— JALX-12
JALX-20 JALX-21
— JALX-22
JALX-30 JALX-31
— JALX-32
JALX-40 —
CONDUIT SIZE
BOX1COVER
1/2" 1/2"
1/2" 3/4"
3/4" 1/2"
3/4" 3/4"
1" 1/2"
1" 3/4"
1-1/4"21/2"
TYPE
C
C
C
C
X
X
X
X
X
X
X
X
X
X
X
JLC-20 JLX-21
JL 1-2 JAL 1-3 JAL 4
JCB
JAH-2
JALX-22
JALX-20
DIMENSIONS
SER I ES A B C D E F G
JL 1/2", 3/4" 1-15/16" 11/16" 3-1/4" 4-7/32" 2-3/8" 5-1/8"
JAL 1/2", 3/4", 1" 2-3/8" 1-5/32" 4-3/4" 5-1/4" 4-1/8" 5-7/8"
JAL 1-1/4" 3-3/16" 1-17/32" 4-5/8" 5-1/4" 4-1/8" 5-7/8"
BOX ONLY VOL. CU. IN.
12.5
12.5
12.5
12.5
12.5
12.5
12.5
12.5
BOX ONLY VOL. CU. IN.
26.5
26.5
26.5
26.5
26.5
26.5
39
CATALOG
NUMBER
JCB
JABC
SERIES
JL
JAL
SERIES
JL
JL
JAL
JAL
DEPTH
5/8"
1-1/8"
VOLUME
CU. IN.
1.0
7.5
REPLACEMENT HUB COVER
CATALOG
NUMBER
JH-1
JH-2
JAH-1
JAH-2
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
DEPTH
1-3/32"
1-3/32"
1-1/8"
1-1/8"
VOLUME
CU. IN.
1.5
1.5
6.5
6.5
G
3-1/4"
4-3/4"
4-13/16"
GU/UN SERIES FITTINGS
UNIONS F61
FEATURES-SPECIFICATIONS
F
Listed File No. E 10514
Certified File No. LR11716
Female to Female Male to Female 90° Elbow Union
DIMENSIONS
1UL & CSA suitable for Class I, Groups A, B, C, D.
•GUF/GUM/UNF/UNY 1/2", 3/4", & 1"
Class I, Div. 1 & 2, Groups A,B,C,D
Class I, Zone I, IIC, IIB, IIA
Class I, Zone 1, Groups IIC, IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
•GUF/GUM/UNF/UNY 1-1/4" through 4"
Class I, Div. 1 & 2, Groups C,D
Class I, Zone I, IIB, IIA
Class I, Zone 1, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
GUML
UNY UNF
HUB SIZE
CATALOG NUMBER
FEMALE TO FEMALE
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
1/2"
3/4"
1"
1-1/4"
1/2"
2"
2-1/2"
3"
3-1/2"
4"
UNF11
UNF21
UNF31
UNF4
UNF5
UNF6
UNF7
UNF8
UNF9
UNF0
GUF-11
GUF-21
GUF-31
GUF-4
GUF-5
GUF-6
GUF-7
GUF-8
GUF-9
GUF-0
2-3/16"(55)
2-3/8"(60)
2-3/4"(70)
2-15/16"(75)
2-15/16"(75)
3-1/4"(82)
4-9/32"(109)
4-1/4"(108)
4-1/2"(114)
4-1/2"(114)
MALE TO FEMALE
UNY11
UNY21
UNY31
UNY4
UNY5
UNY6
UNY7
UNY8
UNY9
UNY0
DIMENSIONS
HUB SIZE
90° ANGLE UNION
1/2"
3/4"
GUML-1M
GUML-2M
GUML-1
GUML-2
Dimensions
1-1/2"(38)
1-3/4"(44)
2"(51)
2-3/8"(60)
2-5/8"(67)
3-1/4"(82)
4-1/2"(114)
5-3/8"(136)
6-1/4"(159)
6-1/4"(159)
GUM-11
GUM-21
GUM-31
GUM-4
GUM-5
GUM-6
GUM-7
GUM-8
GUM-9
GUM-0
Applications
UNY and UNF unions are used to
connect two pieces of conduit or
attach conduit to junction boxes,
fittings, or devices
Permits removal of equipment with-
out turning or removal of conduit
Features
Threaded for rigid conduit or IMC
Tapered threads (NPT)
Strong and durable construction
Material/Finish
Copper-free Aluminum — 1/2"- 4"
(less than 4/10 of 1%)
Natural Finish
Iron — 1-1/4"- 4"
Steel — 1/2", 3/4", 1"
Zinc electro-plate
Third-Party Standards
UL Standard 886
CSA Standard C22.2 No. 30
GUF GUM
1-1/2"(38)
1-3/4"(44)
2"(51)
2-3/8"(60)
2-5/8"(67)
3-1/4"(82)
4-1/2"(114)
5-3/8"(136)
6-1/4"(159)
6-1/4"(159)
1-7/8"(48)
1-15/16"(49)
2-7/16"(62)
2-1/2"(63)
2-1/2"(63)
2-5/8"(67)
3-3/32"(78)
3-1/16"(78)
3-9/16"(90)
3-9/16"(90)
2-1/2"(64)
2"(51)
1-1/2"(38)
1-1/2"(38)
1-3/4"(44)
1-5/8"(42)
KILLARK
ALUM.
DURALOY
IRON
KILLARK
ALUM.
DURALOY
IRON
CATALOG NUMBER
ABC
A DIAMETER B LENGTH
GUF-8 GUM-2 GUML-2
GUML-2MUNY2UNY4
UNF2
GUF-2
For ATEX and IECEx certified
unions, add suffix - EX to the
catalog number.
Example: GUF-1-EX
File nos. ITS09ATEX16417U
IECExITS09.0024U
II2G
Ex d IIC
UNF/UNY SERIES FITTINGS
EXPANSION CONDUIT UNIONS
F62
FEATURES-SPECIFICATIONS
Listed File No. E 10514
Certified File No. LR11716
DIMENSIONS
A B C
HUB
SIZE
CATALOG
NUMBER
FEMALE – SHORT
1/2"
3/4"
1"
UNFS & UNYS — Standard Length
UNFL & UNYL — Long Length
Application
To provide for slight expansion and
contraction of conduit runs
To retrofit sections of conduit runs
Features
Tapered threaded hubs (NPT) for
rigid conduit and IMC
Telescoping components allows
conduit to be inserted between
fixed threaded hubs
Internal copper alloy grounding
spring assures positive grounding
Close tolerance of mating parts
eliminates passage of flame
Compact diameter allows use
where conduit is closely spaced
Available in standard and long
style, male and female version
Material/Finish
Body/Sleeve — Steel/Zinc
Electroplate
Grounding Spring — Beryllium
Copper/Natural Finish
UNFS Type Female/Female UNFL Type Female/Female
UNYS Type Male/Female UNYL Type Male/Female
MAXIMUM LENGTH MAXIMUM LENGTH DIAMETER
UNFS1
UNFS2
UNFS3
3.34 (85)
3.53 (90)
3.69 (94)
2.84 (72)
2.97 (75)
3.08 (78)
1.19 (30)
1.44 (37)
1.69 (43)
DIMENSIONS
A B C
HUB
SIZE
CATALOG
NUMBER
FEMALE – LONG
1/2"
3/4"
1"
MAXIMUM LENGTH MINIMUM LENGTH DIAMETER
UNFL1
UNFL2
UNFL3
4.34 (110)
4.53 (115)
4.69 (119)
3.34 (85)
3.47 (88)
4.58 (116)
1.19 (30)
1.44 (37)
1.69 (43)
DIMENSIONS
A B C
HUB
SIZE
CATALOG
NUMBER
MALE – SHORT
1/2"
3/4"
1"
MAXIMUM LENGTH MINIMUM LENGTH DIAMETER
UNYS1
UNYS2
UNYS3
3.30 (84)
3.41 (87)
3.57 (91)
2.80 (71)
2.85 (72)
2.97 (75)
1.19 (30)
1.44 (37)
1.69 (43)
DIMENSIONS
A B C
HUB
SIZE
CATALOG
NUMBER
MALE – LONG
1/2"
3/4"
1"
MAXIMUM LENGTH MINIMUM LENGTH DIAMETER
UNYL1
UNYL2
UNYL3
4.30 (109)
4.41 (112)
4.57 (117)
3.30 (84)
3.35 (85)
3.47 (88)
1.19 (30)
1.44 (37)
1.69 (43)
UNFS UNFL UNYS UNYL
Class I, Div. 1 & 2, Groups C,D
Class I, Zone 1, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
UL Standard 886
CSA Standard C22.2 No. 30
Mil Spec: MIL-F28675
Dimensions
CUP/PLUG/AN SERIES FITTINGS
THREADED INSERT PLUGS AND RIGID CONDUIT NIPPLES F63
FEATURES-SPECIFICATIONS
F
CUP-0
Application
To close up a taped hole or hub
Features
Threaded hubs (NPT)
Material/Finish
Copper-free Aluminum — 1/4"- 4"
(less than 4/10 of 1%)
Natural Finish
Steel — 1/2"- 1"
Zinc Plated
Iron — 1-1/4"- 4"
Zinc Plated
HUB
SIZE
RECESSED PLUG
CATALOG NUMBER
CUP/CUPX/PLUG 1, 2, & 3,
PLUG 1, 2, & 3-SQ
Class I Groups A,B,C,D
Class I, Zone 1, Groups IIC, IIB, IA
Class II Groups E,F,G
CUP/CUPX/PLUG 1 1/4" through 4"
Class I, Groups C,D
Class I, Zone 1, Groups IIB, IIA
Class II Groups E,F,G
UL Standard: 886
CSA Standard: C22.2 No. 30
Listed File No. E 10514
Certified File No. LR11716
SQUARE HEAD PLUG
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
1/4"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
CUP-1 to 6
CUP-375
CUP-7 to 9
PLUG375
PLUG1
PLUG2
PLUG3
PLUG4
PLUG5
PLUG6
PLUG7
PLUG8
PLUG9
PLUG10
CUP-375
CUP-1
CUP-2
CUP-3
CUP-4
CUP-5
CUP-6
CUP-7
CUP-8
CUP-9
CUP-0
CUPX-250
CUPX-1
CUPX-2
CUPX-3
CUPX-4
CUPX-5
CUPX-6
CUPX-7
CUPX-8
CUPX-9
CUPX-0
STEEL/IRON
KILLARK
ALUMINUM
HUB
SIZE
CATALOG NUMBER
STEEL/IRON
KILLARK
ALUMINUM
PLUG1-SQ
PLUG2-SQ
PLUG3-SQ
PLUG4-SQ
PLUG5-SQ
PLUG6-SQ
PLUG7-SQ
PLUG8-SQ
PLUG9-SQ
PLUG10-SQ
CUPX-250
Square Head
AN
Applications
To connect threaded on IMC
conduit to cast hubs on drilled and
tapped conduit openings
Features
Tapered threads (NPT)
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
CONDUIT SIZE
RIGID CONDUIT NIPPLES
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
5"
6"
AN- 1
AN- 2
AN- 3
AN- 4
AN- 5
AN- 6
AN- 7
AN- 8
AN- 9
AN-10
AN-11
AN-12
AN-1B
AN-2B
AN-3B
CATALOG NUMBER
CLOSE
1-1/2"
1-37/64"
2"
2-1/64"
2-1/16"
2-1/8"
3-9/64"
3-17/64"
3-23/64"
3-15/32"
3-1/2"
3-1/2"
2"
2"
2"
BODY LENGTH BODY LENGTH2" LONG
AN-1 to 5
AN-3B AN-6 up
Listed File No. E 311892
KDB/KB SERIES FITTINGS
DRAINS/BREATHERS/FLAME ARRESTORS
F64
IEC Ex CSA 10.0007u
Certified - File LR11716
KDB-1 KB1B KB1D
Listed - File E10514
IEC Ex CSA 10.0007u
Certified - File LR11716
Certified File 25215
FM
APPROVED
Class I, Div. 1 & 2, Groups B1,C,D
Class I, Zones 1 & 2, Groups IIB + H21
Class II, Div. 1 & 2, Groups E,F,G
Class III, NEMA Type 3
II 2 G Ex d IIB IIC2T226C Gb IP44
1See chart below for
suitability
2Warning - not for use
in acetylene atmosphere
NEW OPTIONS
NEW LISTINGS
ATEX PENDING
4/2011
TYPICAL INSTALATION
1See chart below for suitability
2Warning - not for use in acetylene
atmospheres
2
2
ATEX PENDING 4/2011
Class I, Div. 1 & 2, Groups B1,C,D
Class I, Zones 1 & 2, Groups IIB + H21
Class II, Div. 1 & 2, Groups E,F,G
Class III, NEMA Type 3, 41
II 2 G Ex d IIB IIC2T3 Gb IP661
7/8”
2.96”
KB SERIES FLAME ARRESTOR
KB/KD SERIES DRAIN &
BREATHERS
Applications
When installed in the top of an enclo-
sure, these fittings act as breathers
which allows air flow through the
Applications
The flame arrestor provides a means
to connect gas analysis equipment
and electro pneumatic devices' pipe
or tubing system through the wall of
an explosion-proof enclosure.
BODY MATERIAL: 6061--T6 series
aluminum provided as standard.
Optional stainless steel or brass for
special orders.
enclosure. Bottom installations permit
water from condensation to drain from
the enclosure continuously. The
drains and breathers are offered in a
variety of hub sizes, 1/4, 3/8 & 1/2
inch NPT and metric M16 & M20.
Body Material
Aluminum with optional stainless steel
or brass available for special orders.
Volume
For use in enclosures with a maximum
internal volume to 9526 cubic inches
or 160 liters.
Specifications
Air flow = 83 + 15 / -25 SCFH at 5PSI
Pressure drop = 1.3 PSI at 100 PSI
Maximum flow pressure = 800 PSI
Volume = For use in enclosures with
a maximum internal volume of 9526
cubic inches or 160 liters.
NEW!
R/RE/ADUP SERIES FITTINGS
REDUCING BUSHINGS AND ADAPTERS F65
FEATURES-SPECIFICATIONS
F
UL Standard: 886
CSA Standard: C22.2 No. 30
Listed File No. E 10514
Certified File No. LR11716
1" – 3/4" 2" – 1-1/2" ADUP
Application
To reduce the trade size of a
taped hole or hub.
Features
Tapered threads (NPT)
Smooth internal bushing protects
conductors
Threaded for Rigid Conduit or IMC
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
(R-10 through R-109)
Natural Finish
Steel/Zinc Plated
(RE21S through RE65S)
HUB SIZE
CATALOG NUMBER DIMENSIONS
REDUCING BUSHINGS
BODY LENGTH
• R-10 through R-65
• RE21S through RE65S
Class I, Div. 1 & 2, Groups A,B,C,D
Class I, Zone 1, Groups IIC, IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
• R-73 through R-109
Class I, Div. 1 & 2, Groups A,B,C,D
Class I, Zone 1, Groups IIC, IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
1/2" — 3/8"
3/4" — 3/8"
3/4" — 1/2"
1" — 3/8"
1" — 1/2"
1" — 3/4"
1-1/4" — 1/2"
1-1/4" — 3/4"
1-1/4" — 1"
1-1/2" — 1/2"
1-1/2" — 3/4"
1-1/2" — 1"
1-1/2" — 1-1/4"
2" — 1/2"
2" — 3/4"
2" — 1"
2" — 1-1/4"
2" — 1-1/2"
2-1/2" — 1"
2-1/2" — 1-1/2"
2-1/2" — 2"
3" — 1-1/2"
3" — 2"
3" — 2-1/2"
3-1/2" — 2-1/2"
3-1/2" — 2-1/2"
3-1/2" — 3"
4" — 2"
4" — 2-1/2"
4" — 3"
4" — 3-1/2"
R-10
R-20
R-21
R-30
R-31
R-32
R-41
R-42
R-43
R-51
R-52
R-53
R-54
R-61
R-62
R-63
R-64
R-65
R-73
R-75
R-76
R-85
R-86
R-87
R-96
R-97
R-98
R-106
R-107
R-108
R-109
RE21S
RE31S
RE32S
RE41S
RE42S
RE43S
RE51S
RE52S
RE53S
RE54S
RE61S
RE62S
RE63S
RE64S
RE65S
KILLARK
ALUM. STEEL
5/8"(16)
7/8"(22)
23/32"(18)
7/8"(22)
23/32"(18)
23/32"(18)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
13/16"(21)
7/8"(22)
7/8"(22)
7/8"(22)
7/8"(22)
7/8"(22)
1"(25)
1"(25)
1"(25)
1-1/4"(32)
1-1/4"(32)
1-1/4"(32)
1-3/8"(35)
1-3/8"(35)
1-3/8"(35)
1-1/2"(38)
1-1/2"(38)
1-1/2"(38)
1-1/2"(38)
ADUP ADAPTERS
CATALOG NUMBER1DESCRIPTION
ADUP-01
ADUP-12
MALE 3/8"
FEMALE 1/2"
MALE 1/2"
FEMALE 3/4"
1Series ADUP suitable for Class I, Groups A,B,C,D
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Natural Finish
FF/MF/MM/BL/GUFS/Y/EYMF SERIES FITTINGS
ELBOWS
F66
FEATURES-SPECIFICATIONS
YEYMF
Class I, Div. 1 & 2, Groups C,D
Class II, Div. 1 & 2, Groups E,F,G
Class III
Listed - File E10514
Certified - File LR11716
File 25215
See files for details or call Killark.
FM
APPROVED
FF
Female/Female
MF
Male/Female
MM
Male/Male
BL
Male/Female
GUFS
ELBOWS
FF-90-11
FF-90-21
FF-90-31
FF-45-11
FF-45-21
FF-45-31
FF-45-61
FF-45-81
MF-90-11
MF-90-21
MF-45-11
MF-45-21
MM-90-11
MM-90-21
BL-90-11
BL-90-21
BL-90-31
FF-90-1M3
FF-90-2M3
FF-90-3M3
FF-45-1M3
FF-45-2M3
FF-45-3M3
FF-45-6M3
FF-45-8M3
MF-90-1M3
MF-90-2M3
MF-45-1M3
MF-45-2M3
MM-90-1M3
MM-90-2M3
BL-90-1M3
BL-90-2M3
BL-90-3M3
CATALOG NUMBER
ALUMINUM
FF 90°
FF 90°
FF 90°
FF 45°
FF 45°
FF 45°
FF 45°
FF 45°
MF 90°
MF 90°
MF 90°
MF 90°
MM 90°
MM 90°
BL 90°
BL 90°
BL 90°
1/2"
3/4"
1"
1/2"
3/4"
1"
2"
3"
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1"
2"
2-1/4"
2-15/16"
2-3/8"
2-11/16"
3-3/8"
4-3/4"
5-1/4”
11/16"
7/8"
2-1/8"
2-3/8"
2-1/16"
2-1/4"
2-1/4"
2-5/8"
2-1/4"
2"
2-1/4"
2-15/16"
2"
2-3/16"
2-11/16"
3-7/8"
5-17/64"
2"
2-7/16"
1-3/4"
1-7/8"
2-1/16"
2-1/4"
2-3/8"
3"
3-7/16"
1-3/8"
1-1/2"
2"
1-1/8"
1-1/4"
1-5/8"
2-1/4"
2-17/64"
1-3/8"
1-1/2"
1-1/8"
1-9/32"
1-3/8"
1-1/2"
1-7/8"
2-1/8"
2-5/8"
1-3/8"
1-1/2"
2"
1-3/8"
1-11/16"
3/4"
3/4"
1-3/8"
1-1/2"
1-3/4"
2-1/4"
2-1/2"
IRON TYPE
HUB
SIZE ABCD
CAPPED ELBOWS
Y- 1M4
Y- 2M4
Y- 3M4
Y- 4M4
Y- 5M4
CATALOG NUMBER
ALUMINUM
90°
90°
90°
90°
90°
1/2"
3/4"
1"
1-1/4"
1-1/2"
2-7/8"
3-1/16"
4"
5-1/16"
5-1/16"
2-3/4"
3-3/4"
3-1/4"
4-1/8"
4-1/4"
1-7/8"
2-1/8"
2-5/8"
3-7/8"
3-7/8"
IRON TYPE
HUB
SIZE ABCD
Y- 11
Y- 21
Y- 31
Y- 41
Y- 51
SWIVEL ELBOWS
CATALOG NUMBER
ALUMINUM
180°
180°
180°
180°
1/2"
3/4"
1/2"
3/4"
4-1/2"
4-1/2"
5-1/8"
5-1/4"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
IRON TYPE
HUB
SIZE ABCD
GUFS-12
GUFS-22
GUMFS-12
GUMFS-2 2
GUFS-1M3
GUFS-2M3
GUMFS-1M3
GUMFS-2M3
90° PLUGGED ELBOWS
CATALOG NUMBER5
ALUMINUM
90°
90°
1/2"
3/4"
2-5/8"
2-3/4"
2-5/8"
2-3/4"
1-3/8"
1-1/2"
1-3/8"
1-1/2"
IRON TYPE
HUB
SIZE ABCD
EYMF-12
EYMF-22
Applications
Elbows: To change direction in
rigid or IMC conduit systems
Capped Elbows: To change direc-
tion 90° in rigid or IMC conduit sys-
tems where space is limited and
access is needed for pulling con-
ductors or maintenance
Swivel Elbows: Allows conduit to
be joined at angles ranging
between 90° to 180°. A screwdriver
is the only tool needed
90° Plugged Elbows: To change
direction 90° in rigid or IMC con-
duit systems where space is limited
and access is needed for pulling
conductors or maintenance
Features
Threaded for rigid conduit or IMC
Smooth integral bushings to pre-
vent damage to wires
Material/Finish
Copper-free Aluminum
(less than 4/10 of 1%)
Electrostatically applied powder
coating
Iron Zinc electro-plate
1Copper-free aluminum - Electrostatically applied powder coating
2Aluminum - Natural finish
3Iron - Zinc electroplate
4Iron - Duraloy finish
5Furnished with 1" close-up plug in top.
For ATEX and IECEx certified
elbows, add suffix - EX to the
catalog number.
Example: FF-90-1-EX
File nos. ITS09ATEX16417U
IECExITS09.0024U
II2G
Ex d IIC IP56
ECF/EKJ SERIES FITTINGS
BRONZE FLEXIBLE COUPLINGS F67
FEATURES-SPECIFICATIONS
F
ECF/EKJ FLEXIBLE COUPLINGS
C
DIA.
2-15/16"
2-15/16"
2-15/16"
2-15/16"
2-15/16"
2-15/16"
2-15/16"
3-21/32"
3-21/32"
3-21/32"
3-21/32"
3-21/32"
3-21/32"
3-21/32"
4-9/64"
4-9/64"
4-9/64"
4-9/64"
4-9/64"
4-9/64"
MINIMUM BEND RADIUS
ECF/EKJ FLEXIBLE COUPLINGS
Applications
For use in hazardous areas where
movement or vibration requires
a flexible connection or a difficult
bend is required in a conduit
system.
Features
Bronze flexible metal construction
An inner liner of asphaltum
impreg-nated jute fibre tubing to
protect conductors
Female ends with zinc plated steel
nipples standard on all couplings
Union type couplings may be
assembled by adding a GUF Series
union to the nipple
Special lengths available-consult
factory
All 1/2", 3/4" & 1" EKJ couplings are
furnished with a setscrew (for use
as a fixture hanging coupling)
SERIES 1/2" 3/4" 1 " 1-1/4" 1-1/2" 2"
ECF 10" 12" 14" –
EKJ 10" 12" 14" 14" 16" 18"
ECF CONDUIT
SERIES SIZE
ECF-14 1/2"
ECF-16 1/2"
ECF-18 1/2"
ECF-110 1/2"
ECF-112 1/2"
ECF-115 1/2"
ECF-118 1/2"
ECF-121 1/2"
ECF-124 1/2"
ECF-130 1/2"
ECF-136 1/2"
ECF-24 3/4"
ECF-26 3/4"
ECF-28 3/4"
ECF-210 3/4"
ECF-212 3/4"
ECF-215 3/4"
ECF-218 3/4"
ECF-221 3/4"
ECF-224 3/4"
ECF-230 3/4"
ECF-236 3/4"
ECF-36 1"
ECF-38 1"
ECF-310 1"
ECF-312 1"
ECF-315 1"
ECF-318 1"
ECF-321 1"
ECF-324 1"
ECF-330 1"
ECF-336 1"
EKJ-14
EKJ-16
EKJ-18
EKJ-110
EKJ-112
EKJ-115
EKJ-118
EKJ-24
EKJ-26
EKJ-28
EKJ-210
EKJ-212
EKJ-215
EKJ-218
EKJ-36
EKJ-38
EKJ-310
EKJ-312
EKJ-315
EKJ-318
EKJ-321
EKJ-324
EKJ-330
EKJ-336
CONDUIT
SIZE
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
2"
2"
2"
2"
2"
2"
B
FLEX.
LENGTH
12"
15"
18"
21"
24"
30"
36"
12"
15"
18"
21"
24"
30"
36"
12"
15"
18"
24"
30"
36"
A
OVERALL
LENGTH
18-5/8"
21-5/8"
24-5/8"
27-5/8"
30-5/8"
36-5/8"
42-5/8"
18-15/16"
21-15/16"
24-15/16"
27-15/16"
30-15/16"
36-15/16"
42-15/16"
19-5/16"
22-5/16"
25-5/16"
31-5/16"
37-5/16"
43-5/16"
EKJ-412
EKJ-415
EKJ-418
EKJ-421
EKJ-424
EKJ-430
EKJ-436
EKJ-512
EKJ-515
EKJ-518
EKJ-521
EKJ-524
EKJ-530
EKJ-536
EKJ-612
EKJ-615
EKJ-618
EKJ-624
EKJ-630
EKJ-636
EKJ
SERIES
EKJ
SERIES
1ECF & EKJ 1/2" and 3/4" couplings
suitable for Class I, Groups A,B,C,D
Class l, Zone 1, Groups llC, llB, llA
EKJ 1" thru 2" and ECF 1" couplings
suitable for Class I, Groups C,D.
Class l, Zone 1, Groups llB, llA
All ECF and EKJ are suitable for
Class II and Ill.
B
FLEX.
LENGTH
4"
6"
8"
10"
12"
15"
18"
21"
24"
30"
36"
4"
6"
8"
10"
12"
15"
18"
21"
24"
30"
36"
6"
8"
10"
12"
15"
18"
21"
24"
30"
36"
A
OVERALL
LENGTH
8-13/16"
10-13/16"
12-13/16"
14-13/16"
16-13/16"
19-13/16"
22-13/16"
25-13/16"
28-13/16"
34-13/16"
40-13/16"
8-3/4"
10-3/4"
12-3/4"
14-3/4"
16-3/4"
19-3/4"
22-3/4"
25-3/4"
28-3/4"
34-3/4"
40-3/4"
11-3/4"
13-3/4"
15-3/4"
17-3/4"
20-3/4"
23-3/4"
26-3/4"
29-3/4"
35-3/4"
41-3/4"
CATALOG NUMBER DESCRIPTION CAT. NO. DESCRIPTION
C
DIA.
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/16"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-5/8"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
1-15/16"
Listed - File E10514
Certified - File LR11716
See files for details or call Killark.
Class I, Div. 1 & 2, Groups A,B,C,D1
Class l, Zone 1, Groups llC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Raintight
ECF
1/2", 3/4", 1"
EKJ
1/2", 3/4", 1"
EKJ
1-1/4", 1-1/2", 2"
F68
FEATURES-SPECIFICATIONS
ECLK SERIES FITTINGS
BRONZE FLEXIBLE COUPLINGS WITH FEMALE STEEL UNION
ECLK FLEXIBLE COUPLINGS
C
DIA.
2-7/8" (73)
2-7/8" (73)
2-7/8" (73)
2-7/8" (73)
2-7/8" (73)
2-7/8" (73)
2-7/8" (73)
3-21/32" (93)
3-21/32" (93)
3-21/32" (93)
3-21/32" (93)
3-21/32" (93)
3-21/32" (93)
3-21/32" (93)
4-9/64" (105)
4-9/64" (105)
4-9/64" (105)
4-9/64" (105)
4-9/64" (105)
4-9/64" (105)
MINIMUM BEND RADIUS
ECLK FLEXIBLE COUPLINGS
Listed - File E10514
Certified - File LR11716
See files for details or call Killark.
Applications
For use in hazardous areas
where movement or vibra-
tion requires a flexible con-
nection or a difficult bend is
required in a
conduit system.
Features
Bronze flexible metal
construction
An inner liner of asphaltum
impreg-nated jute fibre
tubing to protect conduc-
tors
Provided with one zink
plated steel nipple and
one zink plated steel
female union
Special lengths available
-consult factory
SERIES 1/2" 3/4" 1 " 1-1/4" 1-1/2" 2"
ECF 10" 12" 14" –
EKJ 10" 12" 14" 14" 16" 18"
ECLK CONDUIT
SERIES SIZE
ECFUF-14 1/2"
ECFUF-16 1/2"
ECFUF-18 1/2"
ECFUF-110 1/2"
ECFUF-112 1/2"
ECFUF-115 1/2"
ECFUF-118 1/2"
ECFUF-121 1/2"
ECFUF-124 1/2"
ECFUF-130 1/2"
ECFUF-136 1/2"
ECFUF-24 3/4"
ECFUF-26 3/4"
ECFUF-28 3/4"
ECFUF-210 3/4"
ECFUF-212 3¼4"
ECFUF-215 3/4"
ECFUF-218 3/4"
ECFUF-221 3/4"
ECFUF-224 3/4"
ECFUF-230 3/4"
ECFUF-236 3/4"
ECFUF-36 1"
ECFUF-38 1"
ECFUF-310 1"
ECFUF-312 1"
ECFUF-315 1"
ECFUF-318 1"
ECFUF-321 1"
ECFUF-324 1"
ECFUF-330 1"
ECFUF-336 1"
CONDUIT
SIZE
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
2"
2"
2"
2"
2"
2"
B
FLEX.
LENGTH
12" (305)
15" (381)
18" (457)
21" (533)
24" (610)
30" (762)
36" (914)
12" (305)
15" (381)
18" (457)
21" (533)
24" (610)
30" (762)
36" (914)
12" (305)
15" (381)
18" (457)
24" (610)
30" (762)
36" (914)
A
OVERALL
LENGTH
20-1/4" (514)
21-1/4" (591)
24-1/4" (667)
27-1/4" (743)
30-1/4" (819)
36-1/4" (972)
42-1/4" (1124)
21-15/16" (557)
24-15/16" (633)
27-15/16" (710)
30-15/16" (786)
33-15/16" (862)
39-15/16" (1014)
45-15/16" (1167)
21-9/16" (548)
24-9/16" (624)
27-9/16" (700)
33-9/16" (852)
39-9/16" (1005)
45-9/16" (1157)
EKJUF-4 1 2
EKJUF-4 1 5
EKJUF-4 1 8
EKJUF-4 2 1
EKJUF-4 2 4
EKJUF-4 3 0
EKJUF-4 3 6
EKJUF-5 1 2
EKJUF-5 1 5
EKJUF-5 1 8
EKJUF-5 2 1
EKJUF-5 2 4
EKJUF-5 3 0
EKJUF-5 3 6
EKJUF-6 1 2
EKJUF-6 1 5
EKJUF-6 1 8
EKJUF-6 2 4
EKJUF-6 3 0
EKJUF-6 3 6
ECLK
SERIES
Class I, Div. 1 & 2, Groups A,B,C,D1
Class l, Zone 1, Groups llC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Raintight
1/2" and 3/4" couplings
suitable for:
Class I, Groups A,B,C,D
Class l, Zone 1, Groups
llC, llB, llA.
• 1" couplings suitable for:
Class I, Groups C,D.
Class l, Zone 1, Groups
llB, llA
1All ECLK couplings are
suitable for:
Class II and Ill.
B
FLEX.
LENGTH
4" (102)
6" (152)
8" (203)
10" (254)
12" (305)
15" (381)
18" (457)
21" (533)
24" (610)
30" (762)
36" (914)
4" (102)
6" (152)
8" (203)
10" (254)
12" (305)
15" (381)
18" (457)
21" (533)
24" (610)
30" (762)
36" (914)
6" (102)
8" (152)
10" (254)
12" (305)
15" (381)
18" (457)
21" (533)
24" (610)
30" (762)
36" (914)
A
OVERALL
LENGTH
10-1/8" (257)
12-1/8" (310)
14-1/8" (359)
16-1/8" (410)
18-1/8" (460)
21-1/8" (537)
24-1/8" (613)
27-1/8" (689)
30-1/8" (765)
36-1/8" (918)
42-1/8" (1070)
10-1/4" (260)
12-1/4" (311)
14-1/4" (362)
16-1/4" (413)
18-1/4" (464)
21-1/4" (540)
24-1/4" (616)
27-1/4" (692)
30-1/4" (768)
36-1/4" (921)
42-1/4" (1073)
13-3/16" (335)
15-3/16" (386)
17-3/16" (437)
19-3/16" (487)
22-3/16" (564)
25-3/16" (640)
28-3/16" (716)
31-3/16" (792)
37-3/16" (945)
43-3/16" (1097)
CAT. NO. DESCRI P TION CAT. NO. DESCRIPTION
ECFUF
1/2", 3/4", 1"
EKJUF
1-1/4", 1-1/2", 2"
C
DIA.
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-1/2" (38)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
1-3/4" (44)
2" (51)
2" (51)
2" (51)
2" (51)
2" (51)
2" (51)
2" (51)
2" (51)
2" (51)
2" (51)
ECFUF 1/2", 3/4", 1" EKJUF 1-1/4", 1-1/2", 2"
EKJ SERIES FITTINGS
STAINLESS STEEL FLEXIBLE COUPLINGS F69
F
FEATURES-SPECIFICATIONS
Features
Available in custom lengths.
See catalog logic to order
Stainless steel wirebraid
construction
Annular corrugated seamless hose
Cast in ribs for easy installation
1/2" – 2" sizes furnished with two
zinc plated steel nipples
2-1/2" – 4" sizes furnished with two
aluminum nipples
Certified - File LR11716
1See files for details or call Killark.
File JIOE3H1.AE
FM
APPROVED
EKJ 2 12
2410
SS
Series Stainless Steel
Trade Size
1/2" — 1
3 /4" 2
1"—3
1-1 /4" 4
1-1 /2" 5
2" — 6
Braid Length
(Specify in whole inches)
examples 12" — 12
24" — 24
Sizes 1/2" Thru 2"
Trade Size
2-1/2" — 7
3" — 8
4" 10
Braid Length
(Specify in whole inches)
examples 12" — 12
24" — 24
Sizes 2-1/2" Thru 4"
Ordering Example - EKJS-1024
(4" trade size, 24" length)
Ordering Example - EKJ-212 SS
(3/4" trade size, 12" length)
EKJ S
Series
Stainless Steel
Class I, Div. 1 & 2, Groups C, D1
Class I, Zone 1, Groups llB, llA1
Class II, Div. 1 & 2, Groups E, F, G
Class III
For ATEX and IEC Ex certified
flexible couplings, contact factory.
Catalog Number Logic
EKJ
1/2"-2"
EKJ
2-1/2"-4"
K SERIES FITTINGS
LIQUIDTIGHT CONNECTORS
F70
FEATURES-SPECIFICATIONS
LIQUIDTIGHT ®
Applications
Use with metallic and non-metallic
conduit to seal out water, oil and dust
in applications for food processors,
beverage & chemical plants, plastics
fabricators, machine shops, etc.
Liquidtight connectors are also suit-
able for use in hazardous locations
per National Electrical Code (Articles
501-4(b), 502-4(a&b), 503-3(a&b).
Consult these articles for sealing
requirements that may apply.
Liquidtight mesh grips provide a
liquidtight seal and enhanced strain
relief in flexible liquidtight conduit
applications.
Features
Split nylon gland ring – split for
easy installation and greater com-
pression
Digging locknut
Sealing ‘O’-rings included
Reusable
Materials/Finish
Steel/malleable iron
Zinc electro-plated
Mesh Grips
Stainless steel mesh grips are
corrosion resistant and prevent
conduit pull-out in high stress
installations
Listed - File E22699
Certified - File LR70873
See files for details or call Killark.
K2001 K0751-MG
DIMENSIONS
ABC
1-7/16" 19/32" 1-1/16"
1-7/16" 19/32" 1-13/16"
1-9/16" 19/32" 1-3/8"
1-11/16" 21/32" 1-11/16"
2-1/32" 11/16" 2-1/16"
2-7/32" 11/16" 2-3/8"
2-9/32" 23/32" 2-7/8"
3-1/2" 1" 3-5/8"
3-3/4" 1" 4-5/16"
3-3/4" 1" 4-3/4"
3-3/4" 1" 5-5/16"
1-7/16" 21/32" 1-1/16"
1-7/16" 21/32" 1-3/16"
1-5/8" 21/32" 1-3/8"
1-3/4" 23/32" 1-11/16"
2-3/32" 3/4" 2-1/16"
2-9/32" 3/4" 2-3/8"
2-11/32" 25/32" 2-7/8"
3-1/2" 1" 3-5/8"
3-3/4" 1" 4-5/16"
3-3/4" 1" 4-3/4"
3-3/4" 1" 5-5/16"
CATALOG
NUMBER
K038
K050
K075
K100
K125
K150
K200
K250
K300
K350
K400
K0381*
K0501*
K0751*
K1001*
K1251*
K1501*
K2001*
K2501*
K3001*
K3501
K4001*
NPT
SIZE
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
Straight non-insulated
Straight non-insulated
Straight non-insulated
Straight non-insulated
Straight non-insulated
Straight non-insulated
Straight non-insulated
Straight non-insulated
Straight non-insulated
Straight non-insulated
Straight non-insulated
CONNECTOR
STYLE
Straight insulated
Straight insulated
Straight insulated
Straight insulated
Straight insulated
Straight insulated
Straight insulated
Straight insulated
Straight insulated
Straight insulated
Straight insulated
K LIQUIDTIGHT CONNECTORS — STRAIGHT
Dimensions
*For mesh grip, add -MGto Catalog Number. Example K0381-MG.
K SERIES FITTINGS
LIQUIDTIGHT CONNECTORS F71
FEATURES-SPECIFICATIONS
F
K2004
45° Non-Insulated
K20041
45° Insulated
CATALOG
NUMBER
K0389
K0509
K0759
K1009
K1259
K1509
K2009
K2509**
K3009
K4009
K03891*
K05091*
K07591*
K10091*
K12591*
K15091*
K20091*
K25091*
K30091*
K40091*
90° non-insulated
90° non-insulated
90° non-insulated
90° non-insulated
90° non-insulated
90° non-insulated
90° non-insulated
90° non-insulated
90° non-insulated
90° non-insulated
CONNECTOR
STYLE
90° Insulated
90° Insulated
90° Insulated
90° Insulated
90° Insulated
90° Insulated
90° Insulated
90° Insulated
90° Insulated
90° Insulated
K LIQUIDTIGHT CONNECTORS — 90° BEND
K LIQUIDTIGHT CONNECTORS — 45° BEND
DIMENSIONS
DE F G
1-1/2" 5/8" 1" 1-3/4"
1-1/2" 5/8" 1-1/8" 1-3/4"
1-19/32" 5/8" 1-3/8" 1-15/16"
1-3/16" 5/8" 1-5/8" 2-3/16"
2" 11/16" 2-1/16" 2-9/16"
2-3/16" 11/16" 2-3/8" 3"
2-17/32" 23/32" 2-7/8" 3-5/8"
3-3/8" 1" 3-5/8" 4-1/4"
3-11/16" 1" 4-5/16" 4-7/8"
4-3/16" 1" 5-5/16" 5-5/8"
1-9/16" 11/16" 1" 1-3/4"
1-9/16" 11/16" 1-1/8" 1-3/4"
1-21/32" 11/16" 1-3/8" 1-15/16"
1-7/8" 11/16" 1-5/8" 2-3/16"
2-1/16" 3/4" 2-1/16" 2-9/16"
2-1/4" 3/4" 2-3/8" 3"
2-19/32" 25/32" 2-7/8" 3-5/8"
3-3/8" 1" 3-5/8" 4-1/4"
3-11/16" 1" 4-5/16" 4-7/8"
4-3/16" 1" 5-5/16" 5-5/8"
CATALOG
NUMBER
K0384
K0504
K0754
K1004
K1254
K1504
K2004
K03841*
K05041*
K07541*
K10041*
K12541*
K15041*
K20041*
NPT
SIZE
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
45° non-insulated
45° non-insulated
45° non-insulated
45° non-insulated
45° non-insulated
45° non-insulated
45° non-insulated
CONNECTOR
STYLE
45° Insulated
45° Insulated
45° Insulated
45° Insulated
45° Insulated
45° Insulated
45° Insulated
DIMENSIONS
HJK L
1-5/32" 1-9/32" 19/32" 1"
1-5/32" 1-9/32" 19/32" 1-1/8"
1-11/64" 1-7/16" 19/32" 1-3/8"
1-13/32" 1-23/32" 21/32" 1-5/8"
1-27/64" 2-1/32" 5/8" 2-1/16"
1-21/32" 1-15/16" 21/32" 2-3/8"
1-11/16" 2-7/16" 21/32" 2-7/8"
1-7/32" 1-9/32" 21/32" 1"
1-7/32" 1-9/32" 21/32" 1-1/8"
1-15/64" 1-7/16" 21/32" 1-3/8"
1-15/32" 1-23/32" 23/32" 1-5/8"
1-31/64" 2-1/32" 11/16" 2-1/16"
1-23/32" 1-15/16" 23/32" 2-3/8"
1-3/4" 2-7/16" 23/32" 2-7/8"
LIQUIDTIGHT ®
Applications
Use with metallic and non-metallic
conduit to seal out water, oil and dust
in applications for food processors,
beverage & chemical plants, plastics
fabricators, machine shops, etc.
Liquidtight connectors are also suit-
able for use in hazardous locations
per National Electrical Code (Articles
501-4(b), 502-4(a&b), 503-3(a&b).
Consult these articles for sealing
requirements that may apply.
Features
Split nylon gland ring – split for easy
installation and greater compression
Digging locknut
Sealing ‘O’-rings included
Reusable
Materials/Finish
Steel/malleable iron
Zinc electro-plated
Dimensions
K0759
90° Non-Insulated
K07591-MG K20041-MG
K07591
90° Insulated
*For mesh grip, add -MG to Catalog Number. Example K03891-MG.
** Use K25091 insulated.
Listed - File E22699
Certified - File LR70873
See files for details or call Killark.
NPT
SIZE
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
4"
K SERIES FITTINGS
GROUNDED LIQUIDTIGHT CONNECTORS
F72
FEATURES-SPECIFICATIONS
LIQUIDTIGHT ®
K Grounding style
Application & Installation
Liquidtight Connectors with ground-
ing lug are for use where an external,
visible equipment bonding jumper is
desired and where permitted by the
National Electrical Code. The Code
specifies length limitations and that
the bonding jumper must be parallel
to the conduit itself.
Listed - File E152165, E22699
Certified - File LR70873
See files for details or call Killark.
Features
Lay-in grounding lug
Fittings are plated steel for excel-
lent durability
Insulated throat fittings protect con-
ductors from insulation damage
Materials/Finish
Steel/malleable iron
Zinc electro-plated
90°
Straight 45°
CONNECTOR ONLY
NPT
SIZE DESC.
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2
2"
2-1/2”
3
4
3/8"
1/2"
3/4"
1"
1-1/4”
1-1/2"
2
Straight
Insulated
90°
Insulated
45°
Insulated
K LIQUIDTIGHT GROUNDING STYLE & MESH GRIPS
CATALOG NUMBER DIMENSIONS
AB C D E
1-1/16" 19/32" 1-7/16" 25/32"
1-3/16" 19/32" 1-7/16" 25/32"
1-3/8" 19/32" 1-9/16" 25/32"
1-11/16" 21/32" 1-11/16" 25/32"
2-1/16" 5/8" 2-1/32" 25/32"
2-3/8" 5/8" 2-7/32" 25/32"
2-7/8" 21/32" 2-9/32" 25/32"
3-5/8" 1" 3-1/2" 1-11/64" –
4-15/16" 1" 3-3/4" 1-11/64" –
4-3/4" 1" 3-3/4" 1-57/64" –
5-5/16" 1" 3-3/4" 1-57/64" –
1-1/16" 19/32" 1-5/16" 1-7/16" 25/32"
1-3/16" 19/32" 1-5/16" 1-7/16" 25/32"
1-3/8" 19/32" 1-7/16" 1-5/8" 25/32"
1-11/16" 21/32" 1-25/32" 2-3/16" 25/32"
2-1/16" 5/8" 1-31/32" 2-1/2" 25/32"
2-3/8" 5/8" 2-3/16" 2-11/16" 25/32"
2-7/8" 21/32" 2-17/32" 3-1/4" 25/32"
3-5/8" 1" 3-3/8" 4-1/4" 1-11/64"
4-15/16" 1" 3-11/16" 4-7/8" 1-11/64"
5-5/16" 1" 4-3/16" 5-5/8" 1-57/64"
1-1/16" 19/32" 1-3/16" 1-9/32" 25/32"
1-3/16" 19/32" 1-3/16" 1-9/32" 25/32"
1-3/8" 19/32" 1-3/16" 1-7/16" 25/32"
1-11/16" 21/32" 1-3/8" 1-17/32" 25/32"
2-1/16" 5/8" 1-27/64" 1-11/16" 25/32"
2-3/8" 5/8" 1-21/32" 2" 25/32"
2-7/8" 21/32" 1-11/16" 2-1/4" 25/32"
K0381-G
K0501-G
K0751-G
K1001-G
K1251-G
K1501-G
K2001-G
K2501-G
K3001-G
K3501-G
K4001-G
K03891-G
K05091-G
K07591-G
K10091-G
K12591-G
K15091-G
K20091-G
K25091-G
K30091-G
K40091-G
K03841-G
K05041-G
K07541-G
K10041-G
K12541-G
K15041-G
K20041-G
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
GROUNDING STYLE WIRE CAPACITY
3/8" to 2" #14 solid to #4 Stranded
2-1/2" to 3" #14 solid to #1/0 Stranded
3-1/2" to 4" #6 stranded to #250 MCM
Z SERIES FITTINGS
ALUMINUM CORD CONNECTORS F73
FEATURES-SPECIFICATIONS
F
Applications
Use to secure and seal cords or
cables entering enclosures or race-
ways.
Z Series connectors are also suitable
for use in hazardous locations per
National Electrical Code (Articles
501-4(b), 502-4(a&b), 503-3(a&b).
Consult these articles for sealing
requirements that may apply.
Features
Aluminum construction resists
corrosion
Neoprene grommet seals out oil
and moisture
Nylon retention ring ensures superi-
or holding power
Wide range of sizes and configura-
tions
Material/Finish
Copper-free aluminum
(less than 4/10 of 1%)
Natural finish
Listed - File E22698
Certified - File LR73478
See files for details or call Killark.
.062-.125
.125-.187
.187-.250
.250-.312
.312-.375
.375-.437
.062-.125
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.062-.125
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
1.375-1.500
1.500-1.625
1.625-1.750
1.750-1.875
1.250-1.375
1.375-1.500
1.500-1.625
1.625-1.750
1.750-1.875
1.688-1.812
1.812-1.937
1.937-2.062
2.062-2.188
2.188-2.312
1.688-1.812
1.812-1.937
1.937-2.062
2.062-2.188
2.188-2.312
2.312-2.437
1.688-1.812
1.937-2.062
2.062-2.188
2.188-2.312
2.312-2.437
2.437-2.625
2.625-2.812
2.812-3.000
3.000-3.250
.375-.500
.500-.625
.625-.750
.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
Green
Orange
Red
Black
White
Blue
Green
Orange
Red
White
Blue
Brown
Yellow
Purple
Green
Orange
Red
White
Blue
Brown
Yellow
Purple
Blue
Brown
Yellow
Purple
Gray
Pink
ZS001
ZS002
ZS003
ZS004
ZS006
ZS007
ZS101
ZS102
ZS103
ZS105
ZS108
ZS109
ZS110*
ZS111*
ZS201
ZS202
ZS203
ZS205
ZS208
ZS209
ZS210
ZS211*
ZS308
ZS309
ZS310
ZS311
ZS312
ZS313*
ZS314*
ZS315*
ZS411
ZS412
ZS413
ZS414
ZS415*
ZS511
ZS512
ZS513
ZS514
ZS515
ZS516
ZS517*
ZS518*
ZS520*
ZS615
ZS616
ZS617
ZS618
ZS620
ZS619
ZS621
ZS622*
ZS623*
ZS624*
ZS719
ZS721
ZS722
ZS723
ZS724
ZS725*
ZS819
ZS822
ZS823
ZS824
ZS825
ZS826
ZS827
ZS828
ZS829*
.99
.99
.99
.99
.99
.99
1.13
1.13
1.13
1.13
1.13
1.13
1.40
1.40
1.29
1.29
1.29
1.29
1.29
1.29
1.40
1.40
1.81
1.81
1.81
1.81
1.81
2.31
2.31
2.31
2.31
2.31
2.31
2.31
2.31
.425
.425
.425
.425
.425
.425
1.10
1.10
1.10
1.10
1.10
1.10
1.50
1.50
1.10
1.10
1.10
1.10
1.10
1.10
1.50
1.50
1.60
1.60
1.60
1.60
1.60
1.70
1.70
1.70
1.70
1.70
1.70
1.70
1.70
.90
.90
.90
.90
.90
.90
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.71
.71
.71
.71
.71
.66
.66
.66
.74
.74
.74
.74
.74
.453
.453
.453
.453
.453
.453
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.815
.815
1.015
1.015
1.015
1.015
1.015
1.015
1.015
1.015
1.255
1.255
1.255
1.255
1.255
2.31
2.31
2.31
2.31
2.31
3.00
3.00
3.00
3.00
3.25
3.25
3.25
3.25
3.25
4.06
4.06
4.06
4.06
4.06
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.87
4.87
4.87
4.87
1.70
1.70
1.70
1.70
1.70
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
.75
.75
.75
.75
.75
.75
.75
.75
.75
.80
.80
.80
.80
.80
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.30
1.30
1.30
1.30
1.30
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.50
1.50
1.50
1.50
1.92
1.92
1.92
1.92
1.92
1.94
1.94
1.94
1.94
1.94
2.34
2.34
2.34
2.34
2.34
2.34
2.54
2.54
2.54
2.54
2.54
3.00
3.00
3.00
3.00
1"
1"
1"
1"
1"
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
3"
3"
3"
3"
3"
3"
3"
3"
3"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
Z CORD CONNECTORS — STRAIGHT Z CORD CONNECTORS — STRAIGHT
* Cable jacket may have to be stripped to pass
through connector body on all sizes.
CATALOG NPT CORD DIMENSIONS
NUMBER SIZE RANGES ABCD
CATALOG NPT CORD COLOR DIMENSIONS
NUMBER SIZE RANGES CODE ABCD
ZS108
Locknut
(See page F71)
Z SERIES FITTINGS
ALUMINUM CORD CONNECTORS
F74
FEATURES-SPECIFICATIONS
OPTIONAL LOCKNUTS AND
SEALING WASHERS
NPT
SIZES
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
CATALOG NUMBER
STEEL SEALING
LOCKNUTS1WASHERS2
KILLN375 —
KILLN1 KOR-1
KILLN2 KOR-2
KILLN3 KOR-3
KILLN4 KOR-4
KILLN5 KOR-5
KILLN6 KOR-6
KILLN7 —
KILLN8 —
12-1/2" through 3" are malleable, with
hexhead flats.
2Neoprene washers are mounted on steel
reinforcing bands.
* Cable jacket may have to be stripped to
pass through connector body.
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.375-.500
.500-.625
.625-.750
.750-.875
.500-.625
.625-.750
.750-.875
.875-1.000
1.000-1.125
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
1.000-1.125
1.250-1.375
1.375-1.500
Orange
Red
White
Blue
Brown
Blue
Brown
Yellow
Purple
Brown
Yellow
Purple
Gray
Pink
ZN102
ZN103
ZN105
ZN108
ZN109*
ZN208
ZN209
ZN210*
ZN211*
ZN309
ZN310
ZN311
ZN312*
ZN313*
ZN412
ZN413
ZN414*
ZN415*
ZN513
ZN515
ZN616
1.56
1.56
1.56
1.56
1.56
1.79
1.79
1.79
1.79
2.08
2.08
2.08
2.08
2.08
3.18
3.18
3.18
3.18
3.18
3.18
3.50
2.30
2.30
2.30
2.30
2.30
2.80
2.80
2.80
2.80
3.20
3.20
3.20
3.20
3.20
4.30
4.30
4.30
4.30
4.30
4.30
5.50
.50
.50
.50
.50
.50
.562
.562
.562
.562
.703
.703
.703
.703
.703
.73
.73
.73
.73
.75
.75
.80
.546
.546
.546
.546
.546
.765
.765
.765
.765
1.00
1.00
1.00
1.00
1.00
1.26
1.26
1.26
1.26
1.50
1.50
1.92
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
2"
CATALOG NPT CORD COLOR
NUMBER SIZE RANGES CODE
DIMENSIONS
A B C D
Z CORD CONNECTORS — 90º
ZN310
Applications
Use to secure and seal cords or
cables entering enclosures or race-
ways.
Z Series connectors are also suit-
able for use in hazardous locations
per National Electrical Code
(Articles 501-4(b), 502-4(a&b),
503-3(a&b). Consult these articles
for sealing requirements that may
apply.
Features
Aluminum construction resists
corrosion
Neoprene grommet seals out oil
and moisture
Nylon retention ring ensures
superior holding power
Wide range of sizes and configu-
rations
Material/Finish
Copper-free aluminum
(less than 4/10 of 1%)
Natural finish
Locknut
Z SERIES FITTINGS
ALUMINUM CORD CONNECTORS WITH MESH GRIP F75
FEATURES-SPECIFICATIONS
F
Applications
Z Series cord connector grips com-
bine aluminum cord connectors with
stainless steel mesh grips to provide
superior cord pull-out prevention in
indoor and outdoor applications.
These grips provide enclosure termi-
nations where cords are subjected to
moisture or splashing water.
They are also suitable for use in haz-
ardous locations per National
Electrical Code (Articles 501-4(b),
502-4(a&b), 503-3(a&b). Consult
these article for sealing requirements
that may apply.
Features
Aluminum fittings are strong,
durable and corrosion resistant
Internal grommet provides liq-
uidtight seal
Stainless steel mesh grips resist
corrosion, prevent cord pull-out
and control arc-of-bend
Material/Finish
Copper-free aluminum
(less than 4/10 of 1%)
Natural finish
Stainless steel mesh grip
Listed - File E22698
Certified - File LR73478
See files for details or call Killark.
.250-.312
.312-.375
.375-.437
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.375-.500
.500-.625
.625-.750
.750-.875
.875-1.00
1.00-1.125
Black
White
Blue
Red
White
Blue
Brown
Yellow
Purple
Red
White
Blue
Brown
Yellow
Purple
Blue
Brown
Yellow
Purple
Gray
Pink
ZS004-MG
ZS006-MG
ZS007-MG
ZS103-MG
ZS105-MG
ZS108-MG
ZS109-MG
ZS110-MG
ZS111-MG
ZS203-MG
ZS205-MG
ZS208-MG
ZS209-MG
ZS210-MG
ZS211-MG
ZS308-MG
ZS309-MG
ZS310-MG
ZS311-MG
ZS312-MG
ZS313-MG
.99
.99
.99
1.13
1.13
1.13
1.13
1.40
1.40
1.29
1.29
1.29
1.29
1.40
1.40
1.81
1.81
1.81
1.81
1.81
2.31
.90
.90
.90
1.10
1.10
1.10
1.10
1.50
1.50
1.10
1.10
1.10
1.10
1.50
1.50
1.60
1.60
1.60
1.60
1.60
1.70
.425
.425
.425
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.71
.71
.71
.71
.71
.66
.453
.453
.453
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.815
.815
1.015
1.015
1.015
1.015
1.015
1.015
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1"
1"
1"
Z CORD CONNECTORS — STRAIGHT
CATALOG NPT CORD COLOR DIMENSIONS
NUMBER SIZE RANGES CODE ABCD
.187-.250
.250-.375
.375-.500
.500-.625
.375-.500
.500-.625
.625-.750
.750-.875
Red
White
Blue
Brown
Blue
Brown
Yellow
Purple
ZN103-MG
ZN105-MG
ZN108-MG
ZN109-MG
ZN208-MG
ZN209-MG
ZN210-MG
ZN211-MG
1.56
1.56
1.56
1.56
1.79
1.79
1.79
1.79
2.30
2.30
2.30
2.30
2.80
2.80
2.80
2.80
.50
.50
.50
.50
.562
.562
.562
.562
.546
.546
.546
.546
.765
.765
.765
.765
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
CATALOG NPT CORD COLOR
NUMBER SIZE RANGES CODE
DIMENSIONS
A B C D
Z CORD CONNECTORS — 90º
Locknut
ZS310-MG
ZN210-MG
OPTIONAL LOCKNUTS AND
SEALING WASHERS
NPT
SIZES
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
CATALOG NUMBER
STEEL SEALING
LOCKNUTS1WASHERS2
KILLN375 —
KILLN1 KOR-1
KILLN2 KOR-2
KILLN3 KOR-3
KILLN4 KOR-4
KILLN5 KOR-5
KILLN6 KOR-6
KILLN7 —
KILLN8 —
12-1/2" through 3" are malleable, with
hexhead flats.
2Neoprene washers are mounted on steel
reinforcing bands.
Z STRAIGHT DIMENSIONS Z 90° DIMENSIONS
Z SERIES FITTINGS
CORROSION RESISTANT NYLON CORD CONNECTORS
F76
FEATURES-SPECIFICATIONS
OPTIONAL LOCKNUTS
Applications
Durable nylon construction makes
these connectors perfectly suited to
corrosive environments.
Typical applications for nylon cord
connectors include food processing
facilities, chemical and sewage treat-
ment plants and off-shore and dock-
side installations.
Features
Nylon retention ring for increased
holding power
Neoprene bushing seals against
moisture
Nylon connectors obtain approxi-
mately the same cord retention
values with hand tightening that can
be produced only by wrench tight-
ening of metal cord connectors
Material
Nylon
Listed - File E22698
Certified - File LR73478
See files for details or call Killark.
CATALOG NPT
NUMBER SIZE
LN-375CR 3/8"
LN-1CR 1/2"
LN-2CR 3/4"
LN-3CR 1"
Z NYLON CORD CONNECTORS STRAIGHT
.125-.187
.187-.250
.250-.312
.312-.375
.375-.437
.062-.125
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.375-.500
.500-.625
.625-.750
.750-.875
.375-.500
.500-.625
.625-.750
.750-.875
.875-1.000
1.000-1.125
Orange
Red
Black
White
Blue
Green
Orange
Red
White
Blue
Brown
Blue
Brown
Yellow
Purple
Blue
Brown
Yellow
Purple
Gray
Pink
ZS002CR
ZS003CR
ZS004CR
ZS006CR
ZS007CR
ZS101CR
ZS102CR
ZS103CR
ZS105CR
ZS108CR
ZS109CR
ZS208CR
ZS209CR
ZS210CR
ZS211CR*
ZS308CR
ZS309CR
ZS310CR
ZS311CR
ZS312CR
ZS313CR*
3/8"
3/8"
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1"
1"
1"
1"
1"
1"
3/4"
3/4"
3/4"
3/4"
CATALOG NPT CORD COLOR
NUMBER* SIZE RANGES CODE
Z NYLON CORD CONNECTORS — 90°
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.375-.500
.500-.625
.625-.750
.750-.875
.625-.750
.750-.875
.875-1.000
Orange
Red
White
Blue
Brown
Blue
Brown
Yellow
Purple
Yellow
Purple
Gray
ZN102CR
ZN103CR
ZN105CR
ZN108CR
ZN109CR
ZN208CR
ZN209CR
ZN210CR*
ZN211CR*
ZN310CR
ZN311CR
ZN312CR*
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
CATALOG NPT CORD COLOR
NUMBER* SIZE RANGES CODE
ZS210CR ZN210CR
NPT
SIZE
3/8"
1/2"
3/4"
1"
DIMENSIONS
ABC D
63/64" 1-3/32" 7/16" 7/16"
1-1/4" 1-1/2" 17/32" 37/64"
1-31/64" 1-5/8" 35/64" 49/64"
1-27/32" 1-3/4" 11/16" 1-1/16"
NPT
SIZE
1/2"
3/4"
1"
DIMENSIONS
ABCD
1-13/32" 2-1/2" 17/32" 1-1/2"
1-21/32" 2-51/64" 35/64" 49/64"
1-63/64" 3-19/64" 11/16" 1-1/64"
* Cable Jacket may have to be stripped to pass
through connector body.
Z SERIES FITTINGS
INCREASED SAFETY ALUMINUM CORD CONNECTORS F77
FEATURES-SPECIFICATIONS
F
Applications
Use to secure and seal cords or cables
entering enclosures or raceways.
Z Series connectors are also suitable
for use in hazardous locations per
National Electrical Code Articles
501-4(b), 502-4(a&b), 503-3(a&b),
505-15 (c); Canadian Electrical Code
18-106, 18-122, 18-156, 18-218,18-
252, 18-302 and 18-352; International
Electrotechnical Commission (IEC)
60079-7 Increased Safety (Ex e II).
Consult these articles for appropriate
installation requirements.
Features
Aluminum construction resists
corrosion
Neoprene grommet seals out oil
and moisture
Nylon retention ring ensures superi-
or holding power
Wide range of sizes and configura-
tions
Material/Finish
Copper-free aluminum
(less than 4/10 of 1%)
Natural finish
.062-.125
.125-.187
.187-.250
.250-.312
.312-.375
.375-.437
.062-.125
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.062-.125
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
1.375-1.500
1.500-1.625
1.625-1.750
1.750-1.875
1.250-1.375
1.375-1.500
1.500-1.625
1.625-1.750
1.750-1.875
1.688-1.812
1.812-1.937
1.937-2.062
2.062-2.188
2.188-2.312
1.688-1.812
1.812-1.937
1.937-2.062
2.062-2.188
2.188-2.312
2.312-2.437
1.688-1.812
1.937-2.062
2.062-2.188
2.188-2.312
2.312-2.437
2.437-2.625
2.625-2.812
2.812-3.000
3.000-3.250
.375-.500
.500-.625
.625-.750
.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
.750-.875
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
Green
Orange
Red
Black
White
Blue
Green
Orange
Red
White
Blue
Brown
Yellow
Purple
Green
Orange
Red
White
Blue
Brown
Yellow
Purple
Blue
Brown
Yellow
Purple
Gray
Pink
ZS001-EX
ZS002-EX
ZS003-EX
ZS004-EX
ZS006-EX
ZS007-EX
ZS101-EX
ZS102-EX
ZS103-EX
ZS105-EX
ZS108-EX
ZS109-EX
ZS110-EX*
ZS111-EX*
ZS201-EX
ZS202-EX
ZS203-EX
ZS205-EX
ZS208-EX
ZS209-EX
ZS210-EX
ZS211-EX*
ZS308-EX
ZS309-EX
ZS310-EX
ZS311-EX
ZS312-EX
ZS313-EX*
ZS314-EX*
ZS315-EX*
ZS411-EX
ZS412-EX
ZS413-EX
ZS414-EX
ZS415-EX*
ZS511-EX
ZS512-EX
ZS513-EX
ZS514-EX
ZS515-EX
ZS516-EX
ZS517-EX*
ZS518-EX*
ZS520-EX*
ZS615-EX
ZS616-EX
ZS617-EX
ZS618-EX
ZS620-EX
ZS619-EX
ZS621-EX
ZS622-EX*
ZS623-EX*
ZS624-EX*
ZS719-EX
ZS721-EX
ZS722-EX
ZS723-EX
ZS724-EX
ZS725-EX*
ZS819-EX
ZS822-EX
ZS823-EX
ZS824-EX
ZS825-EX
ZS826-EX
ZS827-EX
ZS828-EX
ZS829-EX*
.99
.99
.99
.99
.99
.99
1.13
1.13
1.13
1.13
1.13
1.13
1.40
1.40
1.29
1.29
1.29
1.29
1.29
1.29
1.40
1.40
1.81
1.81
1.81
1.81
1.81
2.31
2.31
2.31
2.31
2.31
2.31
2.31
2.31
.90
.90
.90
.90
.90
.90
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.71
.71
.71
.71
.71
.66
.66
.66
.74
.74
.74
.74
.74
.425
.425
.425
.425
.425
.425
1.10
1.10
1.10
1.10
1.10
1.10
1.50
1.50
1.10
1.10
1.10
1.10
1.10
1.10
1.50
1.50
1.60
1.60
1.60
1.60
1.60
1.70
1.70
1.70
1.70
1.70
1.70
1.70
1.70
.453
.453
.453
.453
.453
.453
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.815
.815
1.015
1.015
1.015
1.015
1.015
1.015
1.015
1.015
1.255
1.255
1.255
1.255
1.255
2.31
2.31
2.31
2.31
2.31
3.00
3.00
3.00
3.00
3.25
3.25
3.25
3.25
3.25
4.06
4.06
4.06
4.06
4.06
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.33
4.87
4.87
4.87
4.87
1.70
1.70
1.70
1.70
1.70
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.20
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
2.70
.75
.75
.75
.75
.75
.75
.75
.75
.75
.80
.80
.80
.80
.80
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.27
1.30
1.30
1.30
1.30
1.30
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.38
1.50
1.50
1.50
1.50
1.92
1.92
1.92
1.92
1.92
1.94
1.94
1.94
1.94
1.94
2.34
2.34
2.34
2.34
2.34
2.34
2.54
2.54
2.54
2.54
2.54
3.00
3.00
3.00
3.00
1"
1"
1"
1"
1"
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
1-1/2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
2-1/2"
3"
3"
3"
3"
3"
3"
3"
3"
3"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
Z CORD CONNECTORS — STRAIGHT Z CORD CONNECTORS — STRAIGHT
* Cable jacket may have to be stripped to pass
through connector body on all sizes.
CATALOG NPT CORD DIMENSIONS
NUMBER SIZE RANGES ABCD
CATALOG NPT CORD COLOR DIMENSIONS
NUMBER SIZE RANGES CODE ABC D
Listed - File E22698
Certified - File LR73478
See files for details or call Killark.
ZS108-EX
Locknut
(See page F79)
† Listed by CSA for Class I, Zone 1 in Canada.
Listed by CSA as a Nationally Recognized
Test Lab (NRTL) for Class l, Div. 2, Class l,
Zone 2 in the United States.
** Type 4 when installed with a proper gasket.
AEx (Class I, Zone 1) Ex e II†
Type 4**
Z SERIES FITTINGS
INCREASED SAFETY ALUMINUM CORD CONNECTORS
F78
FEATURES-SPECIFICATIONS
† Listed by CSA for Class I, Zone 1 in Canada.
Listed by CSA as a Nationally Recognized
Test Lab (NRTL) for Class l, Div. 2, Class l,
Zone 2 in the United States.
** Type 4 when installed with a proper gasket.
OPTIONAL LOCKNUTS AND
SEALING WASHERS
NPT
SIZES
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
CATALOG NUMBER
STEEL SEALING
LOCKNUTS1WASHERS2
KILLN375 —
KILLN1 KOR-1
KILLN2 KOR-2
KILLN3 KOR-3
KILLN4 KOR-4
KILLN5 KOR-5
KILLN6 KOR-6
KILLN7 —
KILLN8 —
12-1/2" through 3" are malleable, with
hexhead flats.
2Neoprene washers are mounted on steel
reinforcing bands.
*Cable jacket may have to be stripped to pass
through connector body.
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.375-.500
.500-.625
.625-.750
.750-.875
.500-.625
.625-.750
.750-.875
.875-1.000
1.000-1.125
.875-1.000
1.000-1.125
1.125-1.250
1.250-1.375
1.000-1.125
1.250-1.375
1.375-1.500
Orange
Red
White
Blue
Brown
Blue
Brown
Yellow
Purple
Brown
Yellow
Purple
Gray
Pink
ZN102-EX
ZN103-EX
ZN105-EX
ZN108-EX
ZN109-EX*
ZN208-EX
ZN209-EX
ZN210-EX*
ZN211-EX*
ZN309-EX
ZN310-EX
ZN311-EX
ZN312-EX*
ZN313-EX*
ZN412-EX
ZN413-EX
ZN414-EX*
ZN415-EX*
ZN513-EX
ZN515-EX
ZN616-EX
1.56
1.56
1.56
1.56
1.56
1.79
1.79
1.79
1.79
2.08
2.08
2.08
2.08
2.08
3.18
3.18
3.18
3.18
3.18
3.18
3.50
2.30
2.30
2.30
2.30
2.30
2.80
2.80
2.80
2.80
3.20
3.20
3.20
3.20
3.20
4.30
4.30
4.30
4.30
4.30
4.30
5.50
.50
.50
.50
.50
.50
.562
.562
.562
.562
.703
.703
.703
.703
.703
.73
.73
.73
.73
.75
.75
.80
.546
.546
.546
.546
.546
.765
.765
.765
.765
1.00
1.00
1.00
1.00
1.00
1.26
1.26
1.26
1.26
1.50
1.50
1.92
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
2"
CATALOG NPT CORD COLOR
NUMBER SIZE RANGES CODE
DIMENSIONS
A B C D
Z CORD CONNECTORS — 90º
Applications
Use to secure and seal cords or
cables entering enclosures or
raceways.
Z Series connectors are also suitable
for use in hazardous locations per
National Electrical Code Articles
501-4(b), 502-4(a&b), 503-3(a&b),
505-15 (c); Canadian Electrical Code
18-106, 18-122, 18-156, 18-218,
18-252, 18-302 and 18-352;
International Electrotechnical
Commission (IEC) 60079-7 Increased
Safety (Ex e II).Consult these articles
for appropriate installation require-
ments.
Features
Aluminum construction resists
corrosion
Neoprene grommet seals out oil
and moisture
Nylon retention ring ensures
superior holding power
Wide range of sizes and config-
urations
Material/Finish
Copper-free aluminum
(less than 4/10 of 1%)
Natural finish
ZN310-EX Locknut
Listed - File E22698
AEx (Class I, Zone 1) Ex e II†
Type 4**
Certified - File LR73478
See files for details or call Killark.
Z SERIES FITTINGS
INCREASED SAFETY ALUMINUM CORD CONNECTOR WITH MESH G RIP F79
FEATURES-SPECIFICATIONS
F
Applications
Z Series cord connector grips com-
bine aluminum cord connectors with
stainless steel mesh grips to provide
superior cord pull-out prevention in
indoor and outdoor applications.
These grips provide enclosure termi-
nations where cords are subjected to
moisture or splashing water.
They are also suitable for use in haz-
ardous locations per National
Electrical Code (Articles 501-4(b),
502-4(a&b), 503-3(a&b), 505-15 (c);
Canadian Electrical Code 18-106,
18-122, 18-156, 18-218, 18-252,
18-302 and 18-352; International
Electrotechnical Commission (IEC)
60079-7 Increased Safety (Ex e II).
Consult these articles for appropriate
installation requirements.
Features
Aluminum fittings are strong,
durable and corrosion resistant
Internal grommet provides liquid-
tight seal
Stainless steel mesh grips resist
corrosion, prevent cord pull-out
and control arc-of-bend
Material/Finish
Copper-free aluminum
(less than 4/10 of 1%)
Natural finish
Stainless steel mesh grip
OPTIONAL LOCKNUTS AND
SEALING WASHERS
NPT
SIZES
3/8"
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
CATALOG NUMBER
STEEL SEALING
LOCKNUTS1WASHERS2
KILLN375 —
KILLN1 KOR-1
KILLN2 KOR-2
KILLN3 KOR-3
KILLN4 KOR-4
KILLN5 KOR-5
KILLN6 KOR-6
KILLN7 —
KILLN8 —
12-1/2" through 3" are malleable, with
hexhead flats.
1Neoprene washers are mounted on steel
reinforcing bands.
.250-.312
.312-.375
.375-.437
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.187-.250
.250-.375
.375-.500
.500-.625
.625-.750
.750-.875
.375-.500
.500-.625
.625-.750
.750-.875
.875-1.00
1.00-1.125
Black
White
Blue
Red
White
Blue
Brown
Yellow
Purple
Red
White
Blue
Brown
Yellow
Purple
Blue
Brown
Yellow
Purple
Gray
Pink
ZS004-EX-MG
ZS006-EX-MG
ZS007-EX-MG
ZS103-EX-MG
ZS105-EX-MG
ZS108-EX-MG
ZS109-EX-MG
ZS110-EX-MG*
ZS111-EX-MG*
ZS203-EX-MG
ZS205-EX-MG
ZS208-EX-MG
ZS209-EX-MG
ZS210-EX-MG
ZS211-EX-MG*
ZS308-EX-MG
ZS309-EX-MG
ZS310-EX-MG
ZS311-EX-MG
ZS312-EX-MG*
ZS313-EX-MG*
.99
.99
.99
1.13
1.13
1.13
1.13
1.40
1.40
1.29
1.29
1.29
1.29
1.40
1.40
1.81
1.81
1.81
1.81
1.81
2.31
.425
.425
.425
1.10
1.10
1.10
1.10
1.50
1.50
1.10
1.10
1.10
1.10
1.50
1.50
1.60
1.60
1.60
1.60
1.60
1.70
.90
.90
.90
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.55
.71
.71
.71
.71
.71
.66
.453
.453
.453
.635
.635
.635
.635
.635
.635
.635
.635
.635
.635
.815
.815
1.015
1.015
1.015
1.015
1.015
1.015
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1"
1"
1"
Z CORD CONNECTORS — STRAIGHT
NPT CORD COLOR DIMENSIONS
SIZE RANGES CODE ABCD
.187-.250
.250-.375
.375-.500
.500-.625
.375-.500
.500-.625
.625-.750
.750-.875
Red
White
Blue
Brown
Blue
Brown
Yellow
Purple
ZN103-EX-MG
ZN105-EX-MG
ZN108-EX-MG
ZN109-EX-MG*
ZN208-EX-MG
ZN209-EX-MG
ZN210-EX-MG*
ZN211-EX-MG*
1.56
1.56
1.56
1.56
1.79
1.79
1.79
1.79
2.30
2.30
2.30
2.30
2.80
2.80
2.80
2.80
.50
.50
.50
.50
.562
.562
.562
.562
.546
.546
.546
.546
.765
.765
.765
.765
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
NPT CORD COLOR
SIZE RANGES CODE
DIMENSIONS
A B C D
Z CORD CONNECTORS — 90º
Listed - File E22698
Certified - File LR73478
See files for details or call Killark.
Locknut
ZS310-EX-MG
ZN210-EX-MG
AEx (Class I, Zone 1) Ex e II†
Type 4**
CATALOG
NUMBER
CATALOG
NUMBER
* Cable jacket may have to be stripped to pass
through connector body on all sizes.
† Listed by CSA for Class I, Zone 1 in Canada.
Listed by CSA as a Nationally Recognized
Test Lab (NRTL) for Class l, Div. 2, Class l,
Zone 2 in the United States.
** Type 4 when installed with a proper gasket.
Z 90° DIMENSIONS
Z SERIES FITTINGS
INCREASED SAFETY CORROSION RESISTANT NYLON CORD CONNECTORS
F80
FEATURES-SPECIFICATIONS
Listed - File E22698
Certified - File LR73478
See files for details or call Killark.
ZS210CR-EX ZN210CR-EX
OPTIONAL LOCKNUTS
Applications
Durable nylon construction makes
these connectors perfectly suited to
corrosive environments.
Typical applications for nylon cord
connectors include food processing
facilities, chemical and sewage treat-
ment plants and off-shore and dock-
side installations.
Features
Nylon retention ring for increased
holding power
Neoprene bushing seals against
moisture
Nylon connectors obtain approxi-
mately the same cord retention val-
ues with hand tightening that can
be produced only by wrench tight-
ening of metal cord connectors
Material
Nylon CATALOG NPT
NUMBER SIZE
LN-375CR 3/8"
LN-1CR 1/2"
LN-2CR 3/4"
LN-3CR 1"
Z NYLON CORD CONNECTORS STRAIGHT
.125-.187
.187-.250
.250-.312
.312-.375
.375-.437
.062-.125
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.375-.500
.500-.625
.625-.750
.750-.875
.375-.500
.500-.625
.625-.750
.750-.875
.875-1.000
1.000-1.125
Orange
Red
Black
White
Blue
Green
Orange
Red
White
Blue
Brown
Blue
Brown
Yellow
Purple
Blue
Brown
Yellow
Purple
Gray
Pink
ZS002CR-EX
ZS003CR-EX
ZS004CR-EX
ZS006CR-EX
ZS007CR-EX
ZS101CR-EX
ZS102CR-EX
ZS103CR-EX
ZS105CR-EX
ZS108CR-EX
ZS109CR-EX
ZS208CR-EX
ZS209CR-EX
ZS210CR-EX
ZS211CR-EX*
ZS308CR-EX
ZS309CR-EX
ZS310CR-EX
ZS311CR-EX
ZS312CR-EX
ZS313CR-EX*
3/8"
3/8"
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1"
1"
1"
1"
1"
1"
3/4"
3/4"
3/4"
3/4"
CATALOG NPT CORD COLOR
NUMBER SIZE RANGES CODE
Z NYLON CORD CONNECTORS — 90°
.125-.187
.187-.250
.250-.375
.375-.500
.500-.625
.375-.500
.500-.625
.625-.750
.750-.875
.625-.750
.750-.875
.875-1.000
Orange
Red
White
Blue
Brown
Blue
Brown
Yellow
Purple
Yellow
Purple
Gray
ZN102CR-EX
ZN103CR-EX
ZN105CR-EX
ZN108CR-EX
ZN109CR-EX
ZN208CR-EX
ZN209CR-EX
ZN210CR-EX*
ZN211CR-EX*
ZN310CR-EX
ZN311CR-EX
ZN312CR-EX*
1/2"
1/2"
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
CATALOG NPT CORD COLOR
NUMBER SIZE RANGES CODE
AEx (Class I, Zone 1) Ex e II†
Type 4**
NPT
SIZE
3/8"
1/2"
3/4"
1"
DIMENSIONS
ABC D
63/64" 1-3/32" 7/16" 7/16"
1-1/4" 1-1/2" 17/32" 37/64"
1-31/64" 1-5/8" 35/64" 49/64"
1-27/32" 1-3/4" 11/16" 1-1/16"
Z STRAIGHT DIMENSIONS
NPT
SIZE
1/2"
3/4"
1"
DIMENSIONS
ABCD
1-13/32" 2-1/2" 17/32" 1-1/2"
1-21/32" 2-51/64" 35/64" 49/64"
1-63/64" 3-19/64" 11/16" 1-1/64"
† Listed by CSA for Class I, Zone 1 in Canada.
Listed by CSA as a Nationally Recognized
Test Lab (NRTL) for Class l, Div. 2, Class l,
Zone 2 in the United States.
** Type 4 when installed with a proper gasket.
* Cable Jacket may have to be stripped to pass
through connector body.
Z SERIES FITTINGS
INCREASED SAFETY CORROSION RESISTANT NYLON CORD CONNECTORS F81
FEATURES-SPECIFICATIONS
F
Listed - File E22698
Certified - File LR73478
See files for details or call Killark.
ZS308CR-EX-MG
OPTIONAL LOCKNUTS
Applications
Durable nylon construction makes
these connectors perfectly suited to
corrosive environments.
Typical applications for nylon cord
connectors include food processing
facilities, chemical and sewage treat-
ment plants and off-shore and dock-
side installations.
Features
Nylon retention ring for increased
holding power
Neoprene bushing seals against
moisture
Nylon connectors obtain approxi-
mately the same cord retention val-
ues with hand tightening that can
be produced only by wrench tight-
ening of metal cord connectors
Material
Nylon
Kevlar mesh grip
CATALOG NPT
NUMBER SIZE
LN-375CR 3/8"
LN-1CR 1/2"
LN-2CR 3/4"
LN-3CR 1"
Z NYLON CORD CONNECTORS STRAIGHT
.187-.250
.250-.312
.312-.375
.187-.250
.250-.375
.375-.500
.375-.500
.500-.625
.625-.750
.500-.625
.625-.750
.750-.875
.875-1.000
Red
Black
White
Red
White
Blue
Blue
Brown
Yellow
Brown
Yellow
Purple
Gray
ZS003CR-EX-MG
ZS004CR-EX-MG
ZS006CR-EX-MG
ZS103CR-EX-MG
ZS105CR-EX-MG
ZS108CR-EX-MG
ZS208CR-EX-MG
ZS209CR-EX-MG
ZS210CR-EX-MG
ZS309CR-EX-MG
ZS310CR-EX-MG
ZS311CR-EX-MG
ZS312CR-EX-MG
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
1"
1"
1"
1"
3/4"
3/4"
3/4"
CATALOG NPT CORD COLOR
NUMBER SIZE RANGES CODE
Z NYLON CORD CONNECTORS — 90°
.250-.375
.375-.500
.375-.500
.500-.625
.625-.750
.625-.750
.750-.875
White
Blue
Blue
Brown
Yellow
Yellow
Purple
ZN105CR-EX-MG
ZN108CR-EX-MG
ZN208CR-EX-MG
ZN209CR-EX-MG
ZN210CR-EX-MG
ZN310CR-EX-MG
ZN311CR-EX-MG
1/2"
1/2"
3/4"
3/4"
3/4"
1"
1"
CATALOG NPT CORD COLOR
NUMBER SIZE RANGES CODE
AEx (Class I, Zone 1) Ex e II†
Type 4**
NPT
SIZE
3/8"
1/2"
3/4"
1"
DIMENSIONS
ABC D
63/64" 1-3/32" 7/16" 7/16"
1-1/4" 1-1/2" 17/32" 37/64"
1-31/64" 1-5/8" 35/64" 49/64"
1-27/32" 1-3/4" 11/16" 1-1/16"
Z STRAIGHT DIMENSIONS
NPT
SIZE
1/2"
3/4"
1"
DIMENSIONS
ABCD
1-13/32" 2-1/2" 17/32" 1-1/2"
1-21/32" 2-51/64" 35/64" 49/64"
1-63/64" 3-19/64" 11/16" 1-1/64"
Z 90° DIMENSIONS
† Listed by CSA for Class I, Zone 1 in Canada.
Listed by CSA as a Nationally Recognized
Test Lab (NRTL) for Class l, Div. 2, Class l,
Zone 2 in the United States.
** Type 4 when installed with a proper gasket.
CTCA SERIES FITTINGS
BARRIER TYPE FOR USE WITH UNARMORED CABLES
F82
FEATURES-SPECIFICATIONS
Applications
Outdoor or Indoor use.
For use with non armored cable,
as permitted by the NEC.
Features
Provides a barrier seal between
the individual insulated conductors
within the cable and prevents
entry of the products of an explo-
sion into the cable.
Assembly of the cable gland
compresses and distributes the
compound evenly to effect a barri-
er seal at the point of entry into the
enclosure.
Class l, Div. 2, Groups A,B,C,D
Class I, Zone 2, AEx d llC
Class l, Zone 2, AEx e ll
Class II, Div. 2, Groups F,G
Class III
IP66
NEMA 4X
CTCA
Max. Length
Entry Thread ‘E’ ‘B’
‘D
Compound
CTCAS050S
CTCAO050
CTCAA050L
CTCAB075
CTCAC100
CTCAC2125
CTCAD200
CTCAE250
CTCAF300
CTCAH350
1/2"
1/2"
1/2"
3/4"
1"
11/4 "
2"
2 1/2"
3"
31/2"
M20
M20
M20
M25
M32
M40
M50
M63
M75
M90
6
6
10
21
42
60
80
100
120
-
0.39"
0.39"
0.64"
0.93"
1.23"
1.59"
1.96"
2.55"
2.98"
3.12"
0.22"
0.37"
0.49"
0.66"
0.87"
1.10"
1.42"
1.81"
2.24"
3.07"
0.35"
0.35"
0.43"
0.64"
0.86"
1.04"
1.46"
1.88"
2.32"
2.79"
0.47"
0.63"
0.81"
1.02"
1.30"
1.61"
2.07"
2.57"
3.07"
3.52"
2.81"
2.81"
2.84"
2.95"
3.11"
3.26"
3.36"
3.56"
3.76"
3.54"
0.94"
0.94"
1.18"
1.42"
1.81"
2.17"
2.56"
3.15"
3.74"
4.18"
1.09"
1.09"
1.36"
1.64"
2.09"
2.50"
2.96"
3.64"
4.31"
4.84"
CATALOG NUMBER
NPT
SIZE METRIC
‘E’
MAX.
INNER
SHEATH
‘D’
MAX.
OVER
CORES MIN. MAX.
‘G’
ACROSS
FLATS
ACROSS
CORNERS
ENTRY THREAD
SIZE
OUTER JACKET ‘B’
HEXAGON
DIMENSIONS
CABLE ACCEPTANCE DETAILS
SIZE
REF.
Os
O
A
B
C
C2
D
E
F
H
Provides an outer deluge seal to
prevent moisture ingress to the
cable armor and enclosure.
Deluge seal is colored red to indi-
cate Hazardous Area product.
Provides a cable retention and low
smoke and fume, zero halogen
seal onto the cables outer sheath.
MAX.
NO. OF
CORES
INNER SHEATH/ CORES
Materials
Copper free aluminum (less than
4/10 of 1%)
Operating Temperature Range
-50°C to +60°C
CMCA SERIES FITTINGS
ALUMINUM CABLE CONNECTORS F83
FEATURES-SPECIFICATIONS
F
Applications
Designed for use with jacketed inter-
locked and continuously welded/
corrugated armor cable where it is
essential to provide positive ground-
ing of cable armor and a NEMA 3, 4,
4X connection. e.g. TEC®or MC type
cable. Use outdoors or indoors.
Features
Provides 360° armor grounding
which is fully inspectable.
Grounding Device remains in con-
tact with cable when disassembed
for inspection.
Provides cable retention and a low
smoke and fume, zero halogen
seal onto the cables outer sheath.
Provides an outer deluge seal to
prevent moisture ingress to the
cable armor and enclosure.
Materials
Copper free aluminum (less than
4/10 of 1%)
Operating Temperature Range
-50°C to +60°C
NEMA 4X
Sealing Backnut
Deluge Seal
Inspectable Armor
Grounding Device
CMCAA050
CMCAB075
CMCAC100
CMCAC2125
CMCAD150
CMCAD200
CMCAE250
CMCAF300
CMCAH350
1/2"
3/4"
1"
11/4"
11/2"
2"
21/2"
3"
31/2 "
M20
M25
M32
M40
M50
M50
M63
M75
M90
0.49"
0.66"
0.87"
1.10"
1.42”
1.42"
1.81"
2.24"
3.18"
0.41"
0.49"
0.85"
1.17"
1.37”
1.37"
1.76"
2.29"
2.92"
0.80"
1.02"
1.29"
1.61"
2.07”
2.07"
2.57"
3.07"
3.52"
3.35"
3.61"
3.90"
4.01"
4.94”
4.94"
5.15"
5.17"
5.17"
1.18"
1.42"
1.81"
2.17"
2.56”
2.56"
3.15"
3.74"
4.18"
1.36"
1.64"
2.09"
2.50"
2.96”
2.96"
3.64"
4.31"
4.84"
CATALOG NUMBER
NPT
SIZE METRIC
MIN. MAX.
ARMOR SHEATH
A’ MIN. MAX.
MAX.
LENGTH
ACROSS
FLATS
ACROSS
CORNERS
ENTRY THREAD
SIZE INNER SHEATH/
CORES OUTER JACKET ‘B’
HEXAGON
DIMENSIONS
CABLE ACCEPTANCE DETAILS
SIZE
REF.
A
B
C
C2
D
D
E
F
H
CMCA
Max. Length
Entry Thread A’ ‘B’
Class I, Div. 2†, Groups A, B, C, D
Class l, Zone 1, AEx e ll
Class II, Div. 1 & 2, Groups E, F, G
Class III
Class I, Zones 1 & 2
Suitable for wet locations
Types 3, 4, 4X
IP66
0.64"
0.93"
1.23"
1.59"
1.96”
1.96"
2.55"
2.98"
3.47"
Cable armor diameter and cable jacket diameter refer to the dimensions across the crest - all dimensions in inches.
† Where explosion proof/flameproof enclosures are being used the CMCA must be installed in conjunction with an approved sealing
fitting. In Division 2 areas the CMCA can be fitted directly to an enclosure which has no source of ignition.
Construction
Details
CMCXA SERIES FITTINGS
ALUMINUM CABLE CONNECTORS
F84
FEATURES-SPECIFICATIONS
CMCXA
Class I, Div. 1 & 2, Groups A, B, C, D
Class l, Zone 1 AEx d llC
Class l, Zone 1 AEx e ll
Class II, Div. 1 & 2, Groups E, F, G
Class III
Suitable for wet locations
Types 3, 4, 4X
IP66
Applications
Designed for use with jacketed inter-
locked and continuously welded/
corrugated armor cable where it is
necessary to provide a complete gas
block/explosion proof seal to the
cable, plus a NEMA 3, 4, 4x connec-
tion. Example: TEC or MC-HL type
cable. Use outdoors or indoors.
Features
Provides 360° armor grounding
which is fully inspectable.
Grounding Device remains in con-
tact with cable when disassembed
for inspection.
Provides a barrier seal between the
individual insulated cores within
the cable and prevents entry of
the products of an explosion into
the cable.
Assembly of the cable gland com-
presses and distributes the compound
evenly to create a barrier seal at the
point of entry into the enclosure.
Provides cable retention and a low
smoke and fume, zero halogen seal
onto the cables outer sheath.
Provides an outer deluge seal to
prevent moisture ingress to the
cable armor and enclosure. Deluge
seal is colored red to indicate
Hazardous Area product.
Materials
Copper free aluminum (less than
4/10 of 1%)
Operating Temperature Range
-50°C to +60°C
NEMA 4X
Sealing Backnut
Deluge Seal
Inspectable Armor
Grounding Device
Construction
Details
Max. Length
Entry Thread ‘E’ ‘B’
‘D
Compound
CMCXAA050
CMCXAB075
CMCXAC100
CMCXAC2125
CMCXAD150
CMCXAD200
CMCXAE250
CMCXAF300
CMCXAH350
1/2"
3/4"
1"
11/4"
11/2"
2"
21/2"
3"
31/2"
M20
M25
M32
M40
M50
M50
M63
M75
M90
0.43"
0.64"
0.86"
1.04"
1.46"
1.46"
1.88"
2.32"
2.79"
10
21
42
60
80
80
100
120
120
0.49"
0.66"
0.87"
1.10"
1.42"
1.42"
1.81"
2.24"
3.18"
0.41"
0.49"
0.85"
1.17"
1.37"
1.37"
1.76"
2.29"
2.92"
0.64"
0.93"
1.23"
1.59"
1.96"
1.96"
2.55"
2.98"
3.47"
0.80"
1.02"
1.29"
1.61"
2.07"
2.07"
2.57"
3.07"
3.52"
2.95"
3.20"
3.54"
3.73"
5.08"
5.08"
5.11"
4.88"
5.02"
1.18"
1.42"
1.81"
2.17"
2.56"
2.56"
3.15"
3.74"
4.18"
1.36"
1.64"
2.09"
2.50"
2.96"
2.96"
3.64"
4.31"
4.84"
CATALOG NUMBER
NPT
SIZE METRIC
MIN. MAX.
ARMOR SHEATH
‘E’
‘D’
MAX.
OVER
CORES
MAX.
NO. OF
CORES
MIN. MAX.
MAX.
LENGTH
ACROSS
FLATS
ACROSS
CORNERS
ENTRY THREAD
SIZE
INNER SHEATH/ CORES OUTER JACKET ‘B’
HEXAGON
DIMENSIONS
CABLE ACCEPTANCE DETAILS
SIZE
REF.
A
B
C
C2
D
D
E
F
H
Sealing chamber
SWZ/LNZ/ZHLN SERIES FITTINGS
SEALING WASHERS AND LOCKNUTS F85
FEATURES-SPECIFICATIONS
F
Increased Safety Locknuts
Used to secure conduit hubs or similiar
products entering an enclosure, these
zink locknuts have an increased safety
terminal for grounding purposes.
ZHLN ZINC LOCKNUTS
SIZE
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
CATALOG NUMBER
ZHLN-170
ZHLN-270
ZHLN-370
ZHLN-470
ZHLN-570
ZHLN-670
ZHLN-770
ZHLN-870
ZHLN-970
NPT DIMENSIONS
DIAMETER
A
1.5"
1.7"
2.0"
2.4"
2.8"
3.3"
3.7"
4.4"
5.0"
HEIGHT
B
11/16"
3/4"
3/4"
53/64"
31/32"
31/32"
1-1/4"
1-1/4"
1-5/16"
LNZ10-050NPT
SWZ60-050NPT ZHLN-170
Sealing (IP) Washers
Sealing washers are commonly
used with cable glands or similar
fittings entering an enclosure.
While these products are not
threaded, they are available with
clearance holes to accommodate a
wide range of threadforms includ-
ing ISO (metric), NPT, PG, BSP,
and ET. Sealing washers are avail-
able in nylon. The most common
combinations are listed. For option-
al combinations, contact Killark.
SWZ NYLON WASHERS
NPT
SIZE CATALOG NUMBER
1/2" SWZ60-050NPT
3/4" SWZ60-075NPT
1" SWZ60-100NPT
1-1/4" SWZ60-125NPT
1-1/2" SWZ60-150NPT
2" SWZ60-200NPT
2-1/2" SWZ60-250NPT
3" SWZ60-300NPT
3-1/2" SWZ60-350NPT
Locknuts
These fittings are commonly used
to secure cable glands or similar
products entering an enclosure.
These products are available in a
wide range of threadforms includ-
ing ISO (metric), NPT, PG,
Imperial, BSPP, BSPT, NPS, ET,
other UK and European, Japanese
and CIS. These products are
available in brass (standard) or
Nylon 6, or can be specially
ordered in 316 stainless steel,
steel and aluminum which can be
plated in nickel, zinc, cadmium
and chromium (Plating not possi-
ble with nylon). The most common
combinations are listed. For
optional combinations, contact
Killark.
LNZ BRASS LOCKNUTS
NPT
SIZE CATALOG
NUMBER
1/2" LNZ10-050NPT
3/4" LNZ10-075NPT
1" LNZ10-100NPT
1-1/4" LNZ10-125NPT
1-1/2" LNZ10-150NPT
2" LNZ10-200NPT
2-1/2" LNZ10-250NPT
3" LNZ10-300NPT
PCC/ECC/RACC SERIES FITTINGS
CONDUIT CLAMPS
F86
FEATURES-SPECIFICATIONS
PARALLEL TYPE EDGE TYPE RIGHT ANGLE TYPE Listed - File E213669
Applications
Designed to secure rigid metal conduit, IMC
or EMT across, parallel or prependicular to
channel, beam and angle supports.
Features
Three styles meet every installation need
Heavy duty U-bolts, hex bolts and hex nuts
Capable of supporting heavy loads
Material/Finish
Malleable iron (hot dipped galvanized) with
steel U-bolts and nuts (mechanically
galvanized).
CATALOG
NUMBER
PCC PARALLEL TYPE CLAMPS
2-7/8"
(73)
3-1/16"
(78)
3-1/4"
(83)
3-5/8"
(92)
3-7/8"
(98)
4-5/8"
(117)
5-1/4"
(133)
5-1/8"
(149)
6-5/16"
(160)
6-13/16"
(173)
1-7/16"
(36)
1-11/16"
(43)
2"
(51)
2-1/8"
(53)
2-3/16"
(56)
2-7/8"
(73)
3-1/4"
(83)
3-1/8"
(98)
4-5/16"
(110)
4-13/16"
(122)
PCC050
PCC075
PCC100
PCC125
PCC150
PCC200
PCC250
PCC300
PCC350
PCC400
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
CONDUIT
SIZE
AB
RACC Type
ECC Type
PCC Type
Dimensions
CATALOG
NUMBER
RACC RIGHT ANGLE TYPE CLAMPS
1"
(25)
1-1/8"
(29)
1-3/8"
(35)
1-3/4"
(44)
2"
(51)
2-1/2"
(64)
2-1/2"
(64)
3-5/8"
(92)
4-1/16"
(103)
4-11/16"
(119)
1-1/4"
(32)
1-3/8"
(35)
1-5/8"
(41)
2"
(51)
2-3/8"
(60)
2-1/2"
(64)
3"
(76)
3-7/8"
(98)
4-9/16"
(116)
5-1/16"
(129)
RACC050
RACC075
RACC100
RACC125
RACC150
RACC200
RACC250
RACC300
RACC350
RACC400
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
CONDUIT
SIZE
AB
2-1/2"
(64)
2-13/16"
(72)
3-1/16"
(78)
3-3/16"
(81)
3-1/2"
(89)
4-1/2"
(114)
3-1/4"
(83)
5-3/8"
(137)
5-7/8"
(149)
6-11/16"
(170)
C
1-13/16"
(46)
1-13/16"
(46)
1-13/16"
(46)
1-13/16"
(46)
1-13/16"
(46)
2-5/8"
(67)
4-7/8"
(124)
2-5/8"
(67)
2-5/8"
(67)
2-5/8"
(67)
D
2-1/16"
(52)
2-1/4"
(57)
2-9/16"
(65)
2-7/8"
(73)
3-1/4"
(83)
4-1/16"
(103)
2-5/8"
(67)
5-1/8"
(130)
5-5/8"
(143)
6-1/8"
(156)
E
CATALOG
NUMBER
ECC EDGE TYPE CLAMPS
2-13/16"
(71)
2-15/16"
(75)
3-1/16"
(78)
3-1/16"
(78)
3-15/16"
(100)
4-1/2"
(114)
5-1/8"
(130)
5-3/4"
(146)
2-1/8"
(54)
2-3/8"
(60)
2-5/8"
(67)
3-1/16"
(78)
3-1/4"
(83)
4-1/16"
(103)
4-5/8"
(117)
5-1/4"
(133)
ECC050
ECC075
ECC100
ECC125
ECC150
ECC200
ECC250
ECC300
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
CONDUIT
SIZE
AB
E
ENCLOSURES INDEX
Section E
DB Series
Junction Boxes ......................................2-3
TE Series
Terminal Enclosures ...............................4-6
GE Series
With Terminal ............................................7
HK Series
ATEX Terminal Boxes ................................8
EXB Series
Junction Boxes ....................................9-12
B7E Series
Junction Boxes ..................................13-14
B7E Series
Junction Boxes .......................................15
XJB Series
Junction Boxes .......................................16
Blank Mounting Pans ............................17
Enclosure Options ...............................18
GL/GLXR Series
Round & Rectangular Lenses ..........18 - 19
KDB/KB Series
Drains and Breathers,
Flame Arrestors.......................................20
CBH Series
Circuit Breaker Handles ..........................21
TWBE Series
Terminal Blocks/Control Operators ..........22
GR Series
Threaded Enclosures .......................23 - 27
HK/2HK Series
Instrument/Device Enclosures..........28 - 31
Conduit Opening Data ..........................32
Ei
DB SERIES ENCLOSURES
JUNCTION BOXES
E2
FEATURES-SPECIFICATIONS
Certified - File LR11716
File 25132
See files for details or call Killark.
FM
APPROVED
Listed - File E10514
Applications
Hazardous locations due to the
presence of combustible dusts or
easily ignitable fibers or flyings
Damp or wet locations (raintight)
Features
Copper-free aluminum (less than
4/10 of 1%)
Surface mounting type box with
raised cover
Mounting lugs included as
standard
Cover screws are stainless steel
Gaskets mechanically fastened to
cover
All DB boxes cast with wall thick-
nesses suitable to drill and tap
conduit openings. Conduit open-
ings may be factory or field
installed.
See chart for conduit size limita-
tions. See page E32 for conduit
opening data
Enclosures are available blank or
with factory modifications, options
and accessories. See catalog
pages E17-22 for additional details
BOX WIDTH “J” DIMENSION
61
8 THRU 20 1-3/8
24 AND LARGER 2
Class II, Dlv. 1 & 2, Groups E,F,G
Class Ill
NEMA 3R, 4, 4X, 9(E,F,G)
MODIFICATIONS
KIT-251 100 Amp ground lug
KIT-252 225 Amp ground lug
CATALOG NUMBER DESCRIPTION
SU2 Hinge installed
SU3 Drain and breather installed
SU8 Pan mounting studs
SUFFIX NUMBER DESCRIPTION
Certified - File LR11716
File 25132
See files for details or call Killark.
E3
FEATURES-SPECIFICATIONS
DB SERIES ENCLOSURES
JUNCTION BOXES
E
FM
APPROVED
Listed - File E10514
Class II, Dlv. 1 & 2, Groups E,F,G
Class Ill
NEMA 3R, 4, 4X, 9(E,F,G)
DB-664
DB-884
DB-886
DB-8106
DB-6126
DB-8146
DB-8188
DB-10106
DB-10148
DB-12148
DB-12168
DB-12188
DB-12248
DB-16188
DB-16248
DB-16368
DB-20248
DB-203010
DB-243010
DB-243610
6"
8"
8"
8"
6"
8"
8"
10"
10"
12"
12"
12"
12"
16"
16"
16"
20"
20"
24"
24"
6"
8"
8"
10"
12"
14"
18"
10"
14"
14"
16"
18"
24"
18"
24"
36"
24"
30"
30"
36"
4"
4"
6"
6"
6"
6"
8"
6"
8"
8"
8"
8"
8"
8"
8"
8"
8"
10"
10"
10"
5-3/8"
7-3/8"
7-3/8"
9-3/8"
11-3/8"
13-3/8"
17-3/8"
9-3/8"
13-3/8"
13-3/8"
15-3/8"
17-3/8"
23-3/8"
17-3/8"
23-3/8"
35-3/8"
23-3/8"
29-3/8"
29-1/8"
35-3/8"
5-3/8"
7-3/8"
7-3/8"
7-3/8"
5-3/8"
7-3/8"
7-3/8"
9-3/8"
9-3/8"
11-3/8"
11-3/8"
11-3/8"
11-3/8"
15-3/8"
15-3/8"
15-3/8"
19-3/8"
19-3/8"
23-1/8"
23-3/8"
4-7/32"
4-5/8"
6-5/8"
6-5/8"
6-7/32"
6-5/8"
8-5/8"
6-1/2"
8-1/2"
8-7/16"
8-9/16"
8-5/8"
8-1/6"
8-9/16"
8-9/16"
8-9/16"
8-9/16"
10-5/8"
10-7/16"
10-7/16"
4-1/4"
5-7/16"
5-7/16"
5-5/16"
4-5/16"
5-5/16"
5-5/16"
7-5/16"
7-5/16"
9-5/16"
9-1/4"
9-5/32"
9-5/16"
13-5/16"
13-5/16"
13-5/16"
17-1/2"
17-1/4"
20"
20"
7-1/4"
9-1/4"
9-1/4"
11-1/4"
13-1/4"
15-1/4"
19-1/4"
11-1/4"
11-1/4"
15-1/4"
14-1/4"
19-1/4"
25-1/4"
19-1/4"
25-1/4"
37-1/4"
25-1/4"
31-1/4"
32"
38"
4-1/4"
5-7/16"
5-7/16"
5-5/16"
4-5/16"
5-5/16"
5-5/16"
7-5/16"
7-5/16"
9-5/16"
9-1/4"
9-5/32"
9-5/16"
13-5/16"
13-5/16"
13-5/16"
17-1/2"
17-1/4"
20"
20"
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
HINGE-4
*HINGE-11L
*HINGE-11L
6307-6
6247-8
6247-8
6247-10
6307-12
6247-14
6247-18
6248-10
6248-14
6249-14
6249-16
6249-18
6249-24
6250-18
6250-24
6250-36
6251-24
6251-30
6252-30
6252-36
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4
4
1rowof1=1
2 rows of 2 = 4
2 rows of 2 = 4
2 rows of 2 = 4
4 rows of 1 = 4
4 rows of 2 = 8
5 rows of 2 = 10
2 rows of 2 = 4
4 rows of 2 = 8
4 rows of 3 = 12
4 rows of 3 = 12
5 rows of 3 = 15
8 rows of 3 = 24
5 rows of 4 = 20
8 rows of 4 = 32
12 rows of 4 = 48
8 rows of 6 = 48
10 rows of 6 = 60
10 rows of 7 = 70
12 rows of 7 = 84
4-1/4"
5-7/16"
5-7/16"
7-9/32"
10-3/16"
11-1/4"
15-1/4"
7-5/16"
11-5/16"
11-5/16"
13-1/4"
15-5/32"
21-5/16"
15-5/16"
21-5/16"
33-5/16"
21-1/2"
27-1/4"
26"
32"
DB ENCLOSURES WITH MOUNTING LUGS
1These limits are necessary to assure 3-1/2 full threads to meet Class II requirements.
2Boxes are not factory machined for a mounting pan. Add suffix SU8 if box is to be supplied with pan mounting studs.
3When pan is ordered without box, it is supplied with studs and hardware for field mounting. Machining of box for pan studs is required.
* 24" wide enclosures are furnished with hinged covers on left side as a standard feature.
Maximum number of “G” series control operators permitted in cover, down + across = total.
Use short style “G” series operators.
MOUNTING
DIMENSIONS
CATALOG
NUMBER
COVER
OPENING
OUTSIDE INSIDE
CATALOG NUMBER MAXIMUM
NUMBER OF
OPERATORS†
MAX SIZE1
CONDUIT OPENING
BACK &
SIDE
ENDS
OPTIONAL
HINGE
TYPE
OPTIONAL
MOUNTING
PAN23
NOMINAL DIMENSIONS
A B C D E F G H X Y
TEF/TEB SERIES TERMINAL ENCLOSURES
FOR POWER AND CONTROL CIRCUITS
E4
FEATURES-SPECIFICATIONS
Applications
Hazardous and corrosive environments
such as refineries, chemical plants,
water treatment and bio gas plants,
and wherever a combustible gas-air
mixture or combustible dust may occur
Used to link electrical wires.Primary
circuit brought into the enclosure is
distributed to field control devices
or sensors
Features
Pre-configured enclosures with DIN rail
mounted terminals installed eliminates
time consuming engineering and
sourcing
Enclosures are available in Fiber-glass
Reinforced Polyester or 316 electro-
polished Stainless Steel
Weidmuller or Phoenix increased safety
600 volt rated DIN rail line-up terminals
Factory installed conduit openings,
cable glands, flange (bonding) plates
and hinges are available upon request.
Dimensions
See page E5 for FRP and page E6 for
steel enclosures.
TEF/TEB ENCLOSURES WITH WEIDMÜLLER TERMINALS
For Phoenix Type UK Terminals—Change Bold “W” to “P”.
1CSA Certified for Class II, Div. 1&2, EFG. UL Listed for Class II, Div. 2, FG.
CATALOG NUMBER
POWER AND CONTROL CIRCUITS
18 22-12 2.5 14
15 22-10 4 14
9 20-8 10 12
24 22-12 2.5 14
21 22-10 4 14
12 20-8 10 12
45 22-12 2.5 14
36 22-10 4 14
24 20-8 10 12
45 22-12 2.5 14
36 22-10 4 14
24 20-8 10 12
18 14-6 16 12
45 22-12 2.5 36
36 22-10 4 36
24 20-8 10 24
18 14-6 16 24
12 12-2 35 24
90 22-12 2.5 72
72 22-10 4 72
48 20-8 10 48
90 22-12 2.5 72
72 22-10 4 72
48 20-8 10 48
36 14-6 16 48
24 12-2 35 48
180 22-12 2.5 144
144 22-10 4 144
96 20-8 10 96
TEF051DW12018 TEB051DW12018
TEF051DW10015 TEB051DW10015
TEF051DW08009 TEB051DW08009
TEF061DW12024 TEB061DW12024
TEF061DW10021 TEB061DW10021
TEF061DW08012 TEB061DW08012
TEF071DW12045 TEB071DW12045
TEF071DW10036 TEB071DW10036
TEF071DW08024 TEB071DW08024
TEF073DW12045 TEB073DW12045
TEF073DW10036 TEB073DW10036
TEF073DW08024 TEB073DW08024
TEF073DW06018 TEB073DW06018
TEF083DW12045 TEB083DW12045
TEF083DW10036 TEB083DW10036
TEF083DW08024 TEB083DW08024
TEF083DW06018 TEB083DW06018
TEF083DW02012 TEB083DW02012
TEF083DW12090 TEB083DW12090
TEF083DW10072 TEB083DW10072
TEF083DW08048 TEB083DW08048
TEF093DW12090 TEB093DW12090
TEF093DW10072 TEB093DW10072
TEF093DW08048 TEB093DW08048
TEF093DW06036 TEB093DW06036
TEF093DW02024 TEB093DW02024
TEF093DW12180 TEB093DW12180
TEF093DW10144 TEB093DW10144
TEF093DW08096 TEB093DW08096
STAINLESS STEEL
FRP
TERMINAL WIRE TERMINAL GROUND
QTY. RANGE SIZE MM2 WIRE
AWG CONNECTIONS
Stainless Steel Enclosure
Size 09
Stainless Steel Enclosure
Size 06
FRP Enclosure
Size 08
Terminal Layout
051 061 071, 073 083
15-45
Terminals
083
48-90
Terminals
093
30-90
Terminals
093
96-180
Terminals
Class I, Div. 2, Groups A,B,C,D
Class I, Zones 1&2, Groups IIC, IIB, IIA
Class II, Dlv. 1 & 2, Groups E,F,G1
Class Ill
NEMA 3, 4, 4X
(A) Ex e II T6 IP66*
Requires factory assembly
* Dependent on cable entry connector types
E5
TEF SERIES TERMINAL ENCLOSURES
FRP DIMENSIONAL DATA
Size 03 Size 04 Size 05
Size 06 Size 07
Size S7
Size 08
Size 09
AVAILABLE ENCLOSURE DEPTHS
DEPTH CODE (h) 1 2* 3 4* 5* 6*
ENCLOSURE 3.6" 5.2" 5.9" 6.7" 7.5" 9"
SIZE (91) (131) (150) (171) (190) (230)
03 x—
04 x—
05 xx
06 xx
07 xxxx
S7 x—x
08 xxxxxx
09 xxxx
*Depth increase due to use of deep style cover
3.6”
(91)
3.6”
(91) h
h
h
h
h
h
E
Size 04 Size 05
Size 06 Size 07
Size 08
AVAILABLE ENCLOSURE DEPTHS
DEPTH CODE (h) 1 3 5 6
ENCLOSURESIZE 3.6"(91) 5.9"(150) 7.5"(190) 9"(230)
04 x—
05 x—
06 xx
07 xx
08 xxxx
09 xxx
TEB SERIES TERMINAL ENCLOSURES
STEEL DIMENSIONAL DATA
E6
h
h
hh
h
Size 09
h
FEATURES-SPECIFICATIONS
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 7(C,D), 9(E,F,G)
Listed - File E10514
Certified - File LR11716
HUB
TYPE
HUB
SIZE ABCDEF
CATALOG
NUMBER
COVER
OPENING
VOLUME
CU. IN.
C
T
X
XTF
3/4"
3/4"
3/4"
3/4"
3-11/16"
(94)
3-5/8"
(92)
2-11/16"
(68)
2-3/4"
(70)
1"
(25)
13/16"
(21)
2-11/16"
(68)
19
GECCT-2-6TB
GECTT-2-6TB
GECXT-2-6TB
GECXTF-2-6TB
GE SERIES OUTLET BOX WITH 6 POINT TERMINAL BLOCK
Applications
GE series conduit boxes with termi-
nals are installed in conduit systems
within hazardous areas to:
Protect conductors in threaded
rigid conduit
Act as pull and splice boxes
Interconnect lengths of conduit
Change conduit direction
Provide access to conductors for
maintenance and future system
changes
Used to link electrical wires.
Primary circuit brought into the
enclosure is distributed to field
control devices or sensors
Features
Water shedding cover-suitable for
wet locations when mounted in
upright position
External cover threads on body
protecting conductors from dam-
age during pulling
No pinching of conductors during
cover installation
Three different hub arrangements
Taper threaded hubs to provide
ground continuity
Smooth integral hub bushing to
protect conductor insulation
when pulling
Weather-resistant finish
Green ground screw standard in
all boxes
Weidmuller 6 point MK3 terminal
block is mounted inside box on
raised pads
GECTT-2-6TB
T Type X Type XTF Type
With Mounting Flange
C Type
Terminal rated 300V max/20
AMP/for wire size #22--12AWG
Hub type XTF furnished with
mounting flange
Material/Finish
Body and cover are copper-free
aluminum (less than 4/10 of 1%)
Finish-Electrostatically applied
powder coating
GE SERIES ENCLOSURES
ALUMINUM OUTLET BODIES WITH TERMINAL BLOCK E7
E
HK SERIES ENCLOSURES
ATEX TERMINAL BOX
E8
ATEX Certified
FEATURES-SPECIFICATIONS
Class I, Div. 1 & 2, Groups A*,B, C,D**
Class l, Zones 1 & 2, Groups llB+H2, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3, 4, 4X
Classified - File E83969
& file E150827
Certified - File LR11716
Ordering Example: HKB-B-T1W102
Description: HKB box with blank cover, with 1/2” NPT (in the side) pad, with qty. ten
2.5mm2Weidmuller terminal blocks.
Dimensions: See pages E30 and E31.
Certified - File 1W1R4-RE
UL DEMKO 06 ATEX 0521635/141023 0539
II2GEExeIIT3-T4
II 2 G EEx d IIC T3 - T4
II 2 D IP66 T110º C - T140º C
UL DEMKO
Increased Safety/Flame Proof
Terminal Enclosure
Applications
Used within hazardous areas to splice
or terminate conductors by means of a
terminal block
Act as pull and splice boxes
Provide access to conductors for main-
tenance and future system changes
Used to link electrical wires. Primary
circuit brought into the enclosure is dis-
tributed to field control devices or sen-
sors
Features
Select from 4 body types and 6 differ-
ent covers
Single port box provided with two 3/4”
NPT standard openings. One addi-
tional 1/2” or 3/4” NPT can be added.
Double port has three 3/4”NPTS as
standard.
Maximum (10) 2.5mm2blocks. Quantity
doubles for 2HKB's.
630 Volts max. and 60 Amps max.
Notes:
* Group A FM only on HK single cover
box. Order with - GA suffix.
** Seal within 18” of enclosure for Group
BCD and within 6” for Group A in
accordance with sections 501-5 and
502-5 of the National Electric Code.
Catalog Number Logic
HK Series ATEX Terminal Box
HKB B *T0W102
Indicates Terminal Block
Wire Size
2 - 2.5 mm2(No. 12 AWG max.)
4-4mm2(No. 10 AWG max.)
6-6mm2(No. 8 AWG max.)
10 - 10 mm2(No. 6 AWG max.)
Indicates Total Number of
Terminal Blocks
2.5 mm2- 10 max.
4 mm2- 8 max.
6 mm2- 6 max.
10 mm2- 4 max.
Type of Manufacturer
W - Weidmuller
Side Alternate Machining
0 - None
1 - 1/2 in. NPT
2 - 3/4 in. NPT
2S - 3/4 in. NPSM
Blank Box Type
HKB - Aluminum
HKBD - Aluminum Deep
HKSB - 316 Stainless Steel
2HKB - Double Port
Cover Assembly
B - Blank Cover
GL - Glass Lens Cover
1GLD - 1 in. Glass Lens Lrg. Cover
2GLD - 2 in. Glass Lens Lrg. Cover
2D - 2 in. high Dome Cover
4D - 4 in. high Dome Cover
Type of Protection
T - ATEX Type d or e
Second Cover Assembly for
2HKB only
B - Blank Cover
GL - Glass Lens Cover
1GLD - 1 in. Glass Lens Lrg. Cover
2GLD - 2 in. Glass Lens Lrg. Cover
2D - 2 in. high Dome Cover
4D - 4 in. high Dome Cover
E9
E
FEATURES-SPECIFICATIONS
Class I, Div. 1 & 2,
Groups B1,C,D
Class I, Zones 1 & 2,
Groups IIB+H2, IIA
Class II, Div. 1 & 2,
Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X2,
7(B,C,D), 9(E,F,G)
CENELEC/ATEX/IEC Ex
Ex d IIB + H2 T5 or T6
Ex tD A21 IP66
Ta< + 60°C
#UL886 - Outlet Boxes and Fittings for use in
Hazardous (Classified) Locations. File #E10514
#UL698 & #UL1203 - Explosion Proof
and Dust Ignition Proof Electrical Equipment.
Files #E83969 & E12379
#C22.2 No. 30-M1986 -Explosion Proof
Enclosure for use in Class I Hazardous
Locations. FILE #LR11716
CENELEC II 2 GD
PTB 07 ATEX 1025U (Empty Housing)
PTB 07 ATEX 1024x (Enclosure with Controls)
IEC Ex 07.0022U
IEC Ex 07.0023
Applications
Locations made hazardous due to
the presence of flammable gases
or vapors, combustible dust, or
easily ignitable fibers and flyings,
and areas which are subject to
corrosion, weather and dampness
Petroleum Refineries, Chemical
and Petrochemical plants with
indoor and outdoor processes
Applications requiring junction,
pull and/or splices boxes
Enclosure to house control sta-
tions, meters, relays, starters, cir-
cuit breakers, terminal blocks and
other equipment or devices
Features
Copper-Free Cast Aluminum
Construction. High strength, lighter
in weight, corrosion resistant
Fewer Cover Bolts. Computer-
aided design lessens the number
of cover bolts by eliminating cor-
ner bolts. Reduces installation and
maintenance time
Gasketed Flange. Nitrile (BUNA-N)
“O” ring gasket is located inside
bolt circle to prevent water seep-
ing into enclosure
Ductile Mounting Lugs. Lugs are
made of ductile aluminum alloy to
adjust to irregular mounting sur-
faces without damaging enclosure.
Enclosure size 8x12x6 and larger
furnished with bi-directional mount-
ing lugs which may be positioned
either vertically or horizontally to
facilitate mounting
Hinges. All enclosure sizes 8x12x6
and larger are supplied as stan-
dard with hinges mounted on the
left side. Smaller enclosures are
drilled for field installation of two
Killark HINGE-9 assemblies or can
be installed at factory by adding
SU2 to catalog number. For hinges
to be located in other positions,
specify when ordering
Recessed Flange Notches.
Flanges are notched to allow for
easier cover opening with prying
instrument without flange damage
Conduit Openings. Enclosures are
cast with wall thickness suitable for
drilling and tapping of conduit
openings in all sides and back of
boxes. Conduit size and location
information is found on dimensional
chart (see page E32). Conduits can
be factory or field installed
Mounting Pan Bosses. Mounting
pan bosses are pre-drilled at factory
for field mounting of optional
mounting pan
Material/Finish
Enclosure: Copper-free aluminum
(less than 4/10 of 1%)
Hinges: Aluminum with stainless
steel hardware
Steel Cover Bolts
Optional Mounting Pans: Sheet
aluminum
Optional Windows: Tempered soda
lime glass
Aluminum Lacquer Paint Finish
Standard
EXB SERIES ENCLOSURES
JUNCTION BOXES
Global applications (ATEX)
Enclosures are available for
global applications with “CEN”
suffix. Assemblies that are
modified to CENELEC/ATEX
standards maintain their North
American certifications.
Enclosures are available blank or
with factory modifications, options
and accessories. See catalog
pages E17-E22 for additional details
ATEX / IEC Ex Certified
1Conduits must be sealed within 18” for
Group B applications.
2NEMA 4X with optional SU-1 modification.
E10
FEATURES-SPECIFICATIONS
CATALOG
NUMBER
NOMINAL ENCLOSURE
INSIDE DIMENSIONS
W'' L'' D''
MAXIMUM
CONDUIT
SIZE
OPTIONAL
MOUNTING
PAN NUMBER
MAXIMUM NUMBER
OF OPERATORS†
EXB-664 N34
EXB-684 N343
EXB-6124 N343
EXB-886 N34
EXB-8104 N34
EXB-8106 N34
EXB-8126 N34
EXB-8128 N34
EXB-10106 N34
EXB-10108 N34
EXB-10146 N34
EXB-10148 N34
EXB-12126 N34
EXB-12128 N34
EXB-12186 N34
EXB-12188 N34
EXB-12246 N34
EXB-12248 N34
EXB-122412 N34
EXB-12368 N34
EXB-123610 N34
EXB-14146 N34
EXB-14148 N34
EXB-16166 N34
EXB-16168 N34
EXB-16248 N34
EXB-162410 N34
EXB-18186 N34
EXB-18188 N34
EXB-18248 N34
EXB-182410 N34
EXB-18308 N3434
EXB-18368 N34
EXB-183610 N34
EXB-203611 N34
EXB-24248 N34
EXB-242410 N34
EXB-24308 N34
EXB-24368 N34
EXB-243610 N34
2"
2"
2"
2"
2"
2"
3"
4"
3"
5"
3"
5"
3"
5"
3"
5"
3"
5"
5"
5"
6"
3"
5"
3"
5"
5"
6"
3"
5"
5"
6"
5
5"
6"
6"
5"
6"
5"
5"
6"
7997-5
7997-1
7997-6
7996-1
7996-2
7996-2
17619
17619
17618
17618
17617
17617
7988-1
7988-1
15515
15515
7988-4
7988-4
7988-4
17620
17620
17621
17621
7995-1
7995-1
17622
17622
17623
17623
15516
15516
22061
15517
15517
17596
8000-1
8000-1
20567
17624
17624
2 rows of 2 = 4
2 rows of 3 = 6
4 rows of 2 = 8
3 rows of 3 = 9
4 rows of 3 = 12
4 rows of 3 = 12
4 rows of 3 = 12
4 rows of 3 = 12
3 rows of 3 = 9
3 rows of 3 = 9
5 rows of 3 = 15
5 rows of 3 = 15
4 rows of 4 = 16
4 rows of 4 = 16
7 rows of 4 = 28
7 rows of 4 = 28
9 rows of 4 = 36
9 rows of 4 = 36
9 rows of 4 = 36
14 rows of 4 = 56
14 rows of 4 = 56
5 rows of 5 = 25
5 rows of 5 = 25
6 rows of 6 = 36
6 rows of 6 = 36
8 rows of 5 = 40
8 rows of 5 = 40
6 rows of 6 = 36
6 rows of 6 = 36
9 rows of 7 = 63
9 rows of 7 = 63
11 rows of 7 =77
13 rows of 7 = 91
13 rows of 7 = 91
13 rows of 7 = 91
9 rows of 9 = 81
9 rows of 9 = 81
9 rows of 7 = 63
11 rows of 7 = 77
11 rows of 7 = 77
Order Mounting pan as separate item and specify if
factory or field installed.
Maximum number of “G” series control operators
permitted in cover, down + across = total. See page
E12 when selecting “G” Series control operators.
Note: For Group B applications all conduit openings
must be sealed within 18" of enclosures.
3Not ATEX approved
4cCSAus only
EXB JUNCTION BOXES AND ENCLOSURES
6x6x4
6x8x4
6x12x4
8x8x6
8x10x4
8x10x6
8x12x6
8x12x8
10x10x6
10x10x8
10x14x6
10x14x8
12x12x6
12x12x8
12x18x6
12x18x8
12x24x6
12x24x8
12x24x12
12x36x8
12x36x10
14x14x6
14x14x8
16x16x6
16x16x8
16x24x8
16x24x10
18x18x6
18x18x8
18x24x8
18x24x10
18x30x8
18x36x8
18x36x10
20x36x11
24x24x8
24x24x10
24x30x8
24x36x8
24x36x10
MODIFICATIONS
DESCRIPTION
100 amp ground lug
225 amp ground lug
Drain & breather
installed (NEMA 7CD)
Drain & breather
installed (NEMA 7BCD)
Drill tap & plug for future
drain and breather
Hinges installed
(6x6, 8x8, 8x10 enclosure)
Special paint finish
Fungus proofing
of enclosure
Do not paint enclosure
Stainless steel external
hardware (NEMA 4X)
SUFFIX NUMBER
KIT-251
KIT-252
SU31
SU3B12
SU94
SU2
SU9
SU14
SU93
SU1
EXB SERIES ENCLOSURES
JUNCTION BOXES
1The installation of a Drain & Breather will void
the NEMA 4-4X ratings of enclosure.
2Not CSA
Hinges
Hinges are provided standard on 6x12x4
EXB boxes and on sizes 8x12x6 and
larger. Smaller size EXB boxes are facto-
ry drilled for field installation of (2)
HINGE-9 on left side.
For replacement hinges use HINGE-
11L for enclosures size 8x12x6
through 16x24x10. HINGE-10L is for
use with box size 18x24x8 and larger.
(See page E18 for hinge information.)
See page E9
for area classification
and certification information
E11
E
Full dimensional details are available on .DFX or .DWG format. See Killark web site.
I
EXB-664 N34
EXB-684 N34
EXB-6124 N34
EXB-886 N34
EXB-8104 N34
EXB-8106 N34
EXB-8126 N34
EXB-8128 N34
EXB-10106 N34
EXB-10108 N34
EXB-10146 N34
EXB-10148 N34
EXB-12126 N34
EXB-12128 N34
EXB-12186 N34
EXB-12188 N34
EXB-12246 N34
EXB-12248 N34
EXB-122412 N34
EXB-12368 N34
EXB-123610 N34
EXB-14146 N34
EXB-14148 N34
EXB-16166 N34
EXB-16168 N34
EXB-16248 N34
EXB-162410 N34
EXB-18186 N34
EXB-18188 N34
EXB-18248 N34
EXB-182410 N34
EXB-18308 N34
EXB-18368 N34
EXB-183610 N34
EXB-203611 N34
EXB-24248 N34
EXB-242410 N34
EXB-24308 N34
EXB-24368 N34
EXB-243610 N34
CATALOG
NUMBER
INTERNAL DIMENSIONS (INCHES)
PAN AVAILABLE FOR DEVICES
A
5
5
5
7
7
7
7
7
9
9
9
9
10.5
10.5
10
10
10.25
10.25
10.25
11
11
13
13
14
14
15
15
17
17
16.38
16.38
16
16
16
18.75
22.25
22.25
23
23
23
B
5
7
11
7
9
9
11
11
9
9
13
13
10.5
10.5
16
16
22.25
22.25
22.25
35
35
13
13
14
14
23
23
17
17
22.13
22.13
29
34
34
34.75
22.25
22.25
29
35
35
C
5.73
5.75
5.75
7.59
7.73
7.59
8
8
10
10
10
10
11.5
11.37
11.5
11.37
11.5
11.37
11.37
12
12
14
14
15.5
15.37
16
16
18
18
17.37
17.23
17.87
17.37
17.23
20.14
23.37
23.23
24
24
24
D
5.73
7.75
11.75
7.59
9.73
9.59
12
12
10
10
14
14
11.5
11.37
17.5
17.37
23.5
23.37
23.37
36
36
14
14
15.5
15.37
24
24
18
18
23.37
23.23
30.8
35.37
35.23
36.14
23.37
23.23
30
36
36
E
4.31
4.18
4.25
6.06
4.06
6.06
6.38
8.38
6.20
8.20
6.20
8.20
6.00
8.00
6.00
8.00
6.00
8.00
12.00
8.12
10.12
6.20
8.20
6.00
8.00
8.12
10.12
6.12
8.12
8.00
10.00
8.00
8.00
10.00
11.13
8.06
10.06
8.12
8.12
10.12
F
10.32
10.25
10.69
12.32
12.32
12.32
13.25
13.25
15.25
15.25
15.25
15.25
16.38
16.38
16.38
16.38
16.38
16.38
16.38
17.25
17.25
19.25
19.25
20.38
20.38
21.25
21.25
23.25
23.25
22.38
22.38
22.37
22.38
22.38
26.44
28.38
28.38
29.25
29.25
29.25
G
10.32
12.25
16.69
12.32
14.32
14.32
17.25
17.25
15.25
15.25
19.25
19.25
16.38
16.38
22.38
22.38
28.38
28.38
28.38
41.25
41.25
19.25
19.25
20.38
20.38
29.25
29.25
23.25
23.25
28.38
28.38
35.37
40.38
40.38
42.44
28.38
28.38
35.25
41.25
41.25
H
6.09
6.12
7.00
8.09
6.32
8.32
8.70
10.70
8.90
10.90
8.90
10.90
8.69
10.69
9.06
11.06
9.32
11.32
15.32
11.40
13.40
9.40
11.40
9.19
11.19
12.00
14.00
10.00
12.00
11.75
13.75
12.37
12.38
14.38
15.56
12.19
14.19
12.40
12.40
14.40
I
N/A
N/A
N/A
N/A
N/A
N/A
3.82
3.82
4.94
4.94
4.94
4.94
6.94
6.94
6.94
6.94
6.94
6.94
6.94
7.00
7.00
9.00
9.00
10.94
10.94
11.38
11.38
13.38
13.38
13.00
13.00
13.25
13.25
13.25
15.75
19.50
19.50
19.56
19.56
19.56
J
4.00
6.00
7.82
6.00
8.00
8.00
7.82
7.82
4.94
4.94
8.94
8.94
6.94
6.94
12.88
12.88
18.88
18.88
18.88
31.00
31.00
9.00
9.00
10.94
10.94
19.38
19.38
13.38
13.38
19.00
19.00
26.5
31.50
31.50
31.75
19.50
19.50
25.56
31.56
31.56
K
7.88
7.88
7.88
9.88
9.88
9.88
10.38
10.38
12.94
12.94
12.94
12.94
14.94
14.94
14.94
14.94
14.94
14.94
14.94
15.00
15.00
17.00
17.00
18.94
18.94
19.38
19.38
21.38
21.38
21.00
21.25
21.00
21.00
21.25
23.75
27.50
27.50
27.56
27.56
27.56
L
N/A
N/A
N/A
N/A
N/A
N/A
14.38
14.38
12.94
12.94
16.94
16.94
14.94
14.94
20.88
20.88
26.88
26.88
26.88
39.00
39.00
17.00
17.00
18.94
18.94
27.38
27.38
21.38
21.38
21.25
21.25
34.50
39.50
39.50
39.75
27.50
27.50
33.56
39.56
39.56
M
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.19
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
EXTERNAL
DIMENSIONS (INCHES)
MOUNTING
DIMENSIONS (INCHES)
EXB DIMENSIONS
EXB SERIES ENCLOSURES
JUNCTION BOXES
* Mounting lug opening 7/16” for boxes up to and including 8128 and 9/16” for boxes 10 x 10 and larger
E12
Full dimensional details are available on .DFX or .DWG format. See KILLARK web-site.
S
2.81
2.81
2.81
4.81
2.81
4.81
3.75
5.75
3.75
5.75
3.75
5.75
3.81
5.81
3.75
5.75
3.81
5.81
9.81
5.75
7.75
3.75
5.75
3.75
5.75
5.75
7.75
3.75
5.75
5.56
8.56
6.06
6.06
8.06
8.47
5.50
7.50
5.75
5.75
7.75
R
2.75
2.75
2.75
3.75
2.75
3.45
3.66
4.66
3.79
4.79
3.79
4.79
4.00
5.00
3.88
4.88
3.94
4.94
6.94
4.97
5.97
3.97
4.97
4.18
5.18
5.22
6.22
4.22
5.22
5.00
6.00
5.18
5.18
6.18
6.88
5.88
6.88
5.35
5.35
6.35
Q
4.88
6.88
10.00
6.88
8.88
8.88
10
10
8
8
12
12
9.88
9.88
15.88
15.88
21.88
21.88
21.88
34
34
12
12
13.88
13.88
22
22
16
16
21.88
21.88
28.88
33.88
33.88
33.97
21.88
21.88
28
34
34
P
2.44
3.44
5.00
3.44
4.44
4.44
5
5
4
4
6
6
4.94
4.94
7.94
7.94
10.94
10.94
10.94
17
17
6
6
6.94
6.94
11
11
8
8
10.94
10.94
14.44
16.94
16.94
16.72
10.88
10.88
14
17
17
O
2.81
2.81
2.81
4.81
2.81
4.18
3.75
5.75
3.75
5.75
3.75
5.75
3.81
5.81
3.13
5.13
3.13
5.13
9.13
5.75
7.75
3.75
5.75
3.75
5.75
5.75
7.75
3.75
5.75
4.88
6.88
4.88
4.88
6.88
8.44
5.50
7.50
5.75
5.75
7.75
N
1.18
1.18
1.18
1.18
1.18
1.18
1.78
1.78
1.91
1.91
1.91
1.91
1.88
1.88
2.06
2.06
2.13
2.13
2.13
2.09
2.09
2.09
2.09
2.06
2.06
2.34
2.34
2.34
2.34
2.32
2.32
2.50
2.50
2.50
2.47
2.88
2.88
2.47
2.47
2.47
OPERATOR AREA
AND SPECS
CATALOG NUMBER
I
EXB CONDUIT & OPERATOR LAYOUT INFORMATION
CONDUIT AREA
EXB SERIES ENCLOSURES
JUNCTION BOXES
* Mounting lug opening 7/16” for boxes up to and including 8128 and 9/16” for boxes 10 x 10 and larger
EXB-664 N34
EXB-684 N34
EXB-6124 N34
EXB-886 N34
EXB-8104 N34
EXB-8106 N34
EXB-8126 N34
EXB-8128 N34
EXB-10106 N34
EXB-10108 N34
EXB-10146 N34
EXB-10148 N34
EXB-12126 N34
EXB-12128 N34
EXB-12186 N34
EXB-12188 N34
EXB-12246 N34
EXB-12248 N34
EXB-122412 N34
EXB-12368 N34
EXB-123610 N34
EXB-14146 N34
EXB-14148 N34
EXB-16166 N34
EXB-16168 N34
EXB-16248 N34
EXB-162410 N34
EXB-18186 N34
EXB-18188 N34
EXB-18248 N34
EXB-182410 N34
EXB-18308 N34
EXB-18368 N34
EXB-183610 N34
EXB-203611 N34
EXB-24248 N34
EXB-242410 N34
EXB-24308 N34
EXB-24368 N34
EXB-243610 N34
V
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
3.0
3.0
3.0
U
4.88
4.88
4.88
6.88
6.88
6.88
6
6
8
8
8
8
9.88
9.88
9.88
9.88
9.88
9.88
9.88
10
10
12
12
13.88
13.88
14
14
16
16
15.88
15.88
15.88
15.88
15.88
17.47
21.88
21.88
22
22
22
T
2.44
2.44
2.44
3.44
3.44
3.44
3
3
4
4
4
4
4.94
4.94
4.94
4.94
4.94
4.94
4.94
5
5
6
6
6.94
6.94
7
7
8
8
7.94
7.94
7.94
7.94
7.94
8.72
10.94
10.94
11
11
11
W
5
5
5
7
9
9
11
11
9
9
13
13
10
10
16
16
22.25
22.25
22.25
35
35
13
13
14
14
22
22
16
16
22
22
29
34
34
34.88
22
22
28
34
34
X
5
7
11
7
7
7
7
7
9
9
9
9
10
10
10
10
10.25
10.25
10.25
11
11
13
13
14
14
14
14
16
16
16
16
16
16
16
18.88
22
22
22
22
22
USE
“LONG
STYLE
G
SERIES
OPERATORS
USE
“EXTENDED”
LENGTH
G
SERIES
OPERATORS
USE
“EXTENDED”
LENGTH
G
SERIES
OPERATORS
USE
“LONG” STYLE
G
SERIES
OPERATORS
DIMENSIONS (SEE PAGE E14) MAXIMUM
CATALOG NOMINAL INSIDE OUTSIDE MOUNTING CONDUIT SIZE
NUMBER WIDTH LENGTH DEPTH WIDTH LENGTH DEPTH WIDTH LENGTH
DRAWING
TOP & SIDES
(A) (B) (C) (D) (E) (F) (G) (H)
FIGURE
BOTTOM
B7EA 6-1/2" 13-1/2" 6-11/16" 11" 18" 9-1/8" 3-5/8" 16-3/8" 1 1-1/2" 1" 4 rows of 2 = 8
B7EB 10" 18-1/2" 6-5/8" 14-1/2" 23" 9-1/8" 7" 21-3/8" 1 1-1/2" 1" 7 rows of 3 = 21
B7EC 8" 15 1/2" 6-11/16" 12-1/2" 20" 9-1/8" 5" 18-3/8" 1 1-1/2" 1" 5 rows of 2 = 10
B7ED 10" 21" 6-11/16" 14-1/2" 25-1/2" 9-1/8" 7" 23-7/8" 1 1-1/2" 1" 8 rows of 3 = 24
B7EE 8" 21-3/4" 8-5/16" 12-1/2" 26-1/4" 10-3/4" 5" 24-5/8" 1 2" 2" 8 rows of 2 = 16
B7EF 13" 22-3/4" 8-3/8" 17-7/8" 27-1/4" 11" 10-3/8" 25-5/8" 1 4" 4" 8 rows of 4 = 32
B7EG 12" 29-3/4" 8-7/8" 16-1/2" 34-1/4" 11-1/2" 9" 32-5/8" 1 5" 4" 8 rows of 3 = 24
B7EH 17" 29-3/4" 8-11/16" 21-1/2" 34-1/4" 11-7/8" 14" 32-5/8" 1 5" 4" 9 rows of 5 = 45
B7EJ 15-1/2" 57-1/2" 9-5/16" 20-1/4" 62-1/4" 15" 18-1/2" 43-1/2" 2 5" 5" 18 rows of 4 = 72
B7EK 13" 20" 6-5/8" 17-1/2" 24-3/4" 9-1/2" 15-1/4" 13" 2 3" 1-1/2" 6 rows of 4 = 24
B7EL 13" 29" 6-5/8" 17-1/2" 33-3/8" 9-1/2" 15-1/4" 21" 2 3" 1-1/2" 9 rows of 4 = 36
B7EM 13" 41" 6-5/8" 17-1/2" 45-3/8" 9-1/2" 15-1/4" 33" 2 3" 1-1/2" 14 rows of 4 = 56
B7EN 13" 50" 6-5/8" 17-1/2" 54-3/8" 9-1/2" 15-1/4" 42" 2 3" 1-1/2" 17 rows of 4 = 68
B7EP33-5/8" 5-13/16" 5-1/16" 5-3/4" 8-1/16" 6-5/16" 3-1/8" 8-1/8" 1 1" 1" 1 row of 2 = 2
B7EQ34-1/4" 9-3/16" 6-5/16" 8-1/8" 13-1/16" 7-13/16" 6-3/8" 7-1/2" 2 1-1/2" 1-1/2" 1 row of 4 = 4
E13
FEATURES-SPECIFICATIONS
E
Class I, Div. 1 & 2,
Groups B,C,D1
Class I, Zone 1 & 2
Groups IIB+H2, IIA
Class II, Div. 1 & 2,
Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D), 9(E,F,G)
#UL1203 - Explosion proof and dust-ignition-proof
electrical equipment for use in hazardous (classified)
locations. Fil e #E8 3 9 6 9
#C22.2 No. 30-M1986-Explosion-proof
Enclosure for use in Class I Hazardous
Locations. FILE #LR11716
Applications
Locations made hazardous due to
the presence of flammable gases
or vapors, combustible dust, or
easily ignitable fibers and flyings,
and areas which are subject to cor-
rosion, weather and dampness
Petroleum Refineries, Chemical
and Petrochemical plants with
indoor and outdoor process
Applications requiring junction, pull
and/or splice boxes
Enclosures to house control sta-
tions, relays, starters, circuit break-
ers, terminal blocks and other
equipment or devices
(Lens viewing windows cannot be added to
the Prism Series Enclosures. Use Killark
Quantum Enclosures where viewing windows
are required.)
Features
Copper-Free Cast Aluminum con-
struction. High strength, lighter in
weight, corrosion resistant
Quick Release, Captivated Cover
Bolts of 316 Grade Stainless Steel.
Triple-lead bolts require only 3-1/2
turns to disengage. Stainless steel
(316 grade) for maximum protec-
tion from corrosion
Gasketed Flange. Nitrile (BUNA-N)
“O” ring gasket is located inside
bolt circle to prevent water seeping
into enclosure
Ductile Mounting Lugs. Lugs are
made of ductile aluminum alloy to
adjust to irregular mounting sur-
faces without damage to enclosure
Hinged Cover is Standard
Recessed Flange Notches. Flanges
are notched to allow for easier
cover opening with prying instru-
ment without flange damage
Conduit Openings. Conduit openings
can be supplied at factory, or can be
field installed. See page E32
Material/Finish
Enclosure: Cast Copper-free
Aluminum (less than 4/10 of 1%)
Hinges: Aluminum with stainless
steel hardware
Cover Bolts: 316 Grade Stainless Steel
Aluminum Lacquer Paint Finish Standard
on all B7E except B7EP and B7EQ
which are powder epoxy as standard
1All Conduits must be sealed within 18" when used in Group B Locations.
2Operator spacing is 2-1/2" to except on B7EG & B7EH spacing is 3" to .
Internal Mounting Pan Thickness is 1/8" except on B7EJ it is 3/16" thick.
B7EJ Enclosure Cover has an Internal Rib Structure. Consult Killark for drawing details before layout of cover devices.
Maximum number of “G” series control operators permitted in cover, down + across = total.
3B7 COMPACT Series - Details on page E15.
B7E JUNCTION BOXES AND ENCLOSURES
MAXIMUM
NUMBER OF
OPERATORS2
B7E SERIES • ENCLOSURES
JUNCTION BOXES
c
Lc
Lc
Lc
L
E14
FEATURES-SPECIFICATIONS
3Internal Mounting Pan Thickness is 1/8"
except on B7EJ it is 3/16" thick.
4B7 COMPACT Series - Details on page E15.
PAN3
CATALOG CATALOG
NUMBER NUMBER
WIDTH LENGTH
(J) (K)
B7EA 19919 5" 11-3/4"
B7EB 19920 8-1/4" 16-3/4"
B7EC 18245 6-1/4" 13-3/4"
B7ED 19921 8-3/8" 19-3/8"
B7EE 19923 6-3/8" 20-3/8"
B7EF 18472 11-5/8" 21-1/4"
B7EG 19924 10" 28"
B7EH 19925 15-3/8" 28-3/8"
B7EJ 18279 13-1/2" 54"
B7EK 19926 11" 18"
B7EL 19927 11" 27"
B7EM 19928 11" 39"
B7EN 19929 11" 47"
B7EP4N/A N/A
B7EQ4N/A N/A
MODIFICATIONS
1 2 The installation of a Drain & Breather will
void the NEMA 4-4X rating of enclosure.
Not CSA.
SUFFIX DESCRIPTION
NUMBER
KIT-251 100 amp ground lug
KIT-252 225 amp ground lug
SU31Drain & breather
installed (NEMA 7CD)
SU3B1 2 Drain & breather
installed (NEMA 7BCD)
SU94 “Drill, tap & plug for future”
drain & breather
SU9 Special paint finish
SU14 Fungus proofing of enclosure
SU93 Do not paint enclosure
Dimensions
(See page E13)
Figure 1 Figure 2
B7E JUNCTION BOXES AND ENCLOSURES
B7E SERIES ENCLOSURES
JUNCTION BOXES
Fixed Lug Position For B7EP
Optional Position For B7EQ
Standard Lug Position For B7EQ
B7EP, B7EQ SERIES • ENCLOSURES
JUNCTION BOXES
FEATURES-SPECIFICATIONS
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+ H2, llA
Class II, Div. 1 & 2, Groups E,F,G1
Class III
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
B7EP B7EQ
Certified - File LR11716
Applications
The PRISM®B7 Series of enclosures are
used in:
Locations made hazardous due to the
presence of flammable gasses or vapors
combustible dust, fibers and flyings, and
areas which are subject to corrosion,
weather and dampness
Petroleum Refineries, Chemical and
Petrochemical plants with indoor and
outdoor processes
Provided as blank enclosures or with fac-
tory modifications such as openings for
“G Series” operators, conduit entries
(NPT and metric), drains and breathers
and terminal blocks.
Features
Compact size enclosures for applica-
tion flexibility
NEMA 4, 4X rated - providing protec-
tion from hose directed water & corrosion
Fewer cover bolts reduce installation
and maintenance time
Removable ductile mounting lugs
adjust to irregular mounting surfaces
See pages C40 - C49 for “G Series”
control operators and accessories
Use ‘long style’ operators
Standard Materials /Finish
Enclosures: Copper-free aluminum
(less than 4/10 of 1% copper content)
Cover Bolts: 316 Stainless Steel
O-ring Gasket: Silicone
Finish: Grey Powder Polyester painted
exterior, electrostatically applied.
KIT-251 100 amp ground lug
SU-2 Hinge-9 Installed
SU3* Drain & Breather installed (NEMA 7CD)
SU3B* Drain & Breather installed (NEMA 7BCD)
SU9 Special paint finish
SU14 Fungus proofing of enclosure
SUFFIX DESCRIPTION
NUMBER
*NOTE: The installation of a Drain & Breather will void the
NEMA 4-4X ratings of enclosure.
MODIFICATIONS
CATALOG OUTSIDE BOX NOMINAL MOUNTING
NUMBER DIMENSIONS INSIDE BOX DIMENSIONS
AB CDE FG H IJ
B7EP 5-3/4 8-1/16 6-5/16 3-5/8 5-13/16 5-1/16 3-1/8 8-1/8 --
B7EQ 8-1/8 13-1/16 7-13/16 4-1/4 9-3/16 6-5/16 2-1/2 11-3/8 6-3/8 7-1/2
DIMENSIONS
CATALOG NUMBER MAX. # CENTER TO CENTER MAX.
ENCLOSURE ONLY OPERATORS SPACING CONDUIT SIZE
B7EP 2 2-1/2 1”
B7EQ 421-1/2”
E15
E
XJB SERIES ENCLOSURES
JUNCTION BOXES
E16
5" 10" 6" 1-1/2" 5-3/4" 7-3/32" 3/8" 13-1/4" 8-1/4" 4" 8" HINGE-9 7998-4
5" 13" 6" 2" 8-1/4" 7-1/4" 3/8" 15-3/4" 8-1/4" 4" 8" HINGE-9 7998-5
XJB JUNCTION BOX ORDERING INFORMATION AND DIMENSIONS
CATALOG
NUMBER
NOMINAL INSIDE
BOX SIZE
WLD
MAXIMUM
CONDUIT
SIZE
MOUNTING
DIMENSIONS
A B C
OUTSIDE BOX
DIMENSIONS
DEGH
4 rows of 2 = 8
5 rows of 2 = 10
4 rows of 3 = 12
5 rows of 3 = 15
5 rows of 3 = 15
6 rows of 3 = 18
6 rows of 3 = 18
18 rows of 6 = 108
12 rows of 7 = 84
12 rows of 7 = 84
15 rows of 7 = 105
9 rows of 9 = 81
Class I, Div. 1 & 2, Groups C,D*
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 7(C,D*) 9(E,F,G)
Listed - File E10514
Certified - File LR11716
See files for details or call Killark.
Contact Killark for current approvals.
FM
APPROVED
Applications
Hazardous locations due to the
presence of flammable gases or
vapors, combustible dusts or easily
ignitable fibers or flyings
Installations at petroleum refineries,
chemical and petrochemical plants,
storage areas and other processing
facilities where hazardous sub-
stances are handled or stored
Use as a junction or pull box or to
enclose control stations, meters,
relays, starters, terminals or other
equipment or devices
Features
Extended cover designed to allow
ease of installation and mainte-
nance of enclosed equipment
Mounting lugs cast as standard
Copper-free cast aluminum alloy
(less than 4/10 of 1%)
Cover bolts or plated steel
Hinges are available and can be
mounted on either right or left side
of box (hinges are mounted on left
side unless specified otherwise)
Mounting pans are 1/8" thick sheet
aluminum
Enclosures are available blank or
with factory modifications, options
and accessories. See catalog
pages E17-E22 for additional details
Conduit Openings
All boxes are cast with wall thickness
suitable for drilling and tapping of
conduit openings which may be fac-
tory or field installed. Drilled and
tapped openings can be provided on
any four sides or back (size limita-
tion of conduit opening shown with
dimensional information). For custom
drilled openings, refer to page E32.
1Conduits must be sealed within 18" in Group C locations.
2Hinges or mounting pans not included as standard.
For ordering information see pages E17 and E18.
* NOTE: Some XJB series enclosures suitable for Group D
only - contact factory.
SUFFIX NUMBER DESCRIPTION
MODIFICATIONS
SU1 Stainless steel cover bolts
SU2 Hinge installed
SU3 Drain and breather installed
KIT-251 100 AMP ground lug
KIT-252 225 AMP ground lug
NUMBER OF
OPERATORS†
CATALOG NUMBER
OPTIONAL
HINGE
TYPE2
OPTIONAL
MOUNTING
PAN2
FEATURES-SPECIFICATIONS
Dimensions
Maximum number of “G” series operators per-
mitted in cover, down + across = total.
Use long style “G” series operators.
8" 13" 6" 2" 8-1/2" 10-9/16" 3/8" 16" 11" 4" 8" HINGE-11L 7996-4
8" 15" 6" 2" 11-1/2" 10-9/16" 3/8" 18-1/2" 11" 4" 8" HINGE-11L 7996-5
8" 15" 8" 4" 11-1/2" 10-9/16" 3/8" 18-1/2" 11" 6-1/8" 10-1/4" HINGE-11L 7996-5
8" 18" 6" 2" 13-1/2" 10-9/16" 3/8" 21" 11" 4" 8" HINGE-11L 7996-6
8" 18" 8" 4" 13-1/2" 10-9/16" 3/8" 21" 11" 6-1/8" 10-1/8" HINGE-11L 7996-6
16" 48" 12" 4" 43-9/16" 18-1/8" 5/8" 51-1/2" 19-1/2" 7-1/4" 14-1/2" HINGE-10L 7995-5
20" 32" 8" 3-1/2” 27-1/2” 21-7/8" 5/8" 35" 23" 6-1/8" 16-1/4" HINGE-10L 7999-2
20" 32" 10" 3-1/2” 27-1/2” 21-7/8" 5/8" 35" 23" 6-1/8" 12-1/4" HINGE-10L 7999-2
20" 40" 10" 3-1/2” 36" 22-3/4" 5/8" 43-1/2" 23-1/2" 6-1/4" 12-1/2" HINGE-10L 7999-3
24" 24" 16" 4" 19-1/2” 26-7/16" 5/8" 27-1/2" 27-1/2" 9-1/4" 18-1/2" HINGE-10L 8000-1
XJB-51061
XJB-5136
XJB-81361
XJB-81561
XJB-81581
XJB-8186
XJB-8188
XJB-1648121
XJB-203281
XJB-2032101
XJB-2040101
XJB-2424161
E17
EXB/XJB/DB SERIES ENCLOSURES
BLANK MOUNTING PANS
E
EXB, XJB MOUNTING PAN
DB MOUNTING PAN
EXB and XJB Series Mounting
Pans Ordering Instructions
Select proper mounting pan based
on inside (length & width) of box.
Order and price as separate item
from junction box catalog number.
EXAMPLE: XJB-164812
7995-5 assemble
EXB and XJB Series boxes have
cast bosses which are drilled and
tapped for direct mounting when
pans are ordered.
Mounting pans are 1/8" or 3-16” thick
sheet aluminum and are sized to pro-
vide the maximum usable surface
area when installed.
All EXB-XJB series boxes have inter-
nal bosses that are factory machined
to accept mounting pans.
}
7998-4 5" 10" 4-1/2" 9" 6-29/32" 3" .125
7998-5 5" 13" 4-1/2" 12" 10" 2" .125
7997-5 6" 6" 5" 5" 3" 3" .125
7997-1 6" 8" 5" 7" 5" 3" .125
7997-6 6" 12" 5" 11" 9" 3" .125
7996-1 8" 8" 7" 7" 5" 5" .125
7996-2 8" 10" 7" 9" 7" 5" .125
17619 8" 12" 7" 11" 9" 5" .125
7996-4 8" 13" 7" 12" 10" 5" .125
7996-5 8" 15" 7" 14-1/2" 12-1/2" 5" .125
7996-6 8" 18" 7" 17" 15-1/8" 5" .125
17617 10" 14" 9" 13" 11" 7" .125
17618 10" 10" 9" 9" 7" 7" .125
7988-1 12" 12" 10-1/2" 10-1/2" 9" 9" .125
15515 12" 18" 10" 16" 15" 9" 7-1/2" .125
7988-4 12" 24" 10-1/4" 22-1/4" 21" 9" .125
17620 12" 36" 11" 35" 33" 9" 17-1/2" .125
17621 14" 14" 13" 13" 11" 11" .125
7995-1 16" 16" 14" 14" 13" 13" .125
7995-2 16" 24" 14-1/2" 23" 21" 13" .125
17622 16" 24" 15" 23" 21" 13" .125
7995-5 16" 48" 14-1/2" 46-1/2" 45" 13" 22-1/2" .190
17623 18" 18" 17" 17" 15" 15" .190
15516 18" 24" 16-3/8" 22-1/8" 21" 15" 10-1/2" .125
15517 18" 36" 34" 16" 33" 15" 16-1/2" .125
7999-1 20" 24" 18-1/2" 22-1/2" 21" 17" .125
7999-2 20" 32" 18-1/2" 30-1/2" 29" 17" 14-1/2" .190
17596 20" 36" 18-3/4" 34-3/4" 32-3/4" 16-3/4" 16-3/8" .190
7999-3 20" 40" 18-1/2" 39" 37" 17" 18-1/2" .190
8000-1 24" 24" 22-1/4" 22-1/4" 21" 21" .125
17624 24" 36" 23" 35" 33" 21" 16-1/2" .190
205767 24" 30" 23" 29" 27" 21" 13-1/2" .190
22061 18" 30" 16" 29" 28" 15" 14" .125
MOUNTING PAN MOUNTING
CATALOG
NOMINAL
DIMENSION HOLE SPACINGS
NUMBER
INSIDE PAN
BOX SIZE A B THICKNESS
WIDTH LENGTH WIDTH LENGTH C D E
6307-6 6" 6"
6307-12 6" 12"
6247-8 8" 8"
6247-10 8" 10"
6247-14 8" 14"
6247-18 8" 18"
6248-10 10" 10"
6248-14 10" 14"
6249-14 12" 14"
6249-16 12" 16"
6249-18 12" 18"
6249-24 12" 24"
6250-18 16" 18"
6250-24 16" 24"
6250-36 16" 36"
6251-24 20" 24"
6251-30 20" 30"
6252-30 24" 30"
6252-36 24" 36"
3" — .125
3" — .125
3-1/4" — .125
3-1/4" — .125
3-1/4" — .125
3-1/4" — .125
5-1/4" — .125
5-1/4" — .125
7-1/4" — .125
7-1/4" — .125
7-1/4" — .125
7-1/4" — .125
11-1/4" — .125
11-1/4" — .125
11-1/4" 15-5/8" .125
15-1/4" — .125
15-1/4" — .125
17" — .125
17" 14-1/2" .190
4" 4" 3"
4" 10" 8-1/2"
5" 5" 3-1/4"
5" 7" 5-1/4"
5" 11" 9-1/4"
5" 15" 13-1/4"
7" 7" 5-1/4"
7" 11" 9-1/4"
9" 11" 9-1/4"
9" 13" 11-1/4"
9" 15" 13-1/4"
9" 21" 19-1/4"
13" 15" 13-1/4"
13" 21" 19-1/4"
13" 33" 31-1/4"
17" 21" 19-1/4"
17" 27" 25-1/4"
18-3/4" 24-3/4" 23"
18-3/4" 30-3/4" 29"
Dimensions
DB Series Mounting Pans
Ordering Instructions
Select proper mounting pan based
on outside (length & width) of box.
Order and price as separate item
from the junction box catalog number.
EXAMPLE: DB-10106 assemble
6248-10
DB Series boxes are provided with
1/2" raised mounting studs threaded
into the back when pans are ordered.
If a mounting pan is not ordered,
mounting studs can still be provided
by adding SU8 to box catalog num-
ber. See price list for SU8 pricing
information.
}
GL/GLX RECOMMENDED MINIMUM SPACING —CENTERLINE TO CENTERLINE
ENCLOSURE OPTIONS ENCLOSURES
HINGES AND GLASS LENS COVERS
E18
FEATURES-SPECIFICATIONS
HINGES
HINGES
Applications
Hinges are installed on flanged enclo-
sures to allow for easier and safer
installation and when performing
maintenance on internal components.
Applications
Use GL Series lens on:
All EXB Boxes
XJB 16" x 48" and XJB 24" x 24"
Use GLX Series lens on:
All DB Boxes
All XJB Boxes except 16" x 48" and
24" x 24"
Refer to recommended minimum spac-
ing table. Series GL and GLX have
identical viewing lens diameter and out-
side diameter. The difference is in the
thread pitch.
GL/GLX ROUND GLASS
LENS COVERS
CATALOG SERIES
NUMBER USED MATERIAL
HINGE-4 DB Stainless steel
HINGE-9 EXB, XJB Stainless steel
HINGE-10L EXB, XJB; Extruded aluminum
HINGE-10R Larger sizes Extruded aluminum
HINGE-11L EXB, Extruded aluminum
HINGE-11R XJB, DB Extruded aluminum
GL/GLX Series
Lens Cover
Round and Rectangular
Lens Covers Must Be
Factory Installed
2-3/4" 4-5/8"
2-61/64" 5-1/4"
3-45/64" 6-1/4"
5-3/8" 7-7/8"
6" 8-7/8"
7-3/4" 10-1/4"
GLASS LENS TYPE GL/GLX-275 GL/GLX-300 GL/GLX-375 GL/GLX-537 GL/GLX-600 GL/GLX-775
GL/GLX-275 7.0 7.5 7.75 8.75 9.0 10.0
GL/GLX-300 7.5 8.0 8.25 9.25 9.5 10.5
GL/GLX-375 7.75 8.25 8.5 9.5 9.75 10.75
GL/GLX-537 8.75 9.25 9.5 10.5 10.75 11.75
GL/GLX-600 9.0 9.5 9.75 10.75 11.0 12.0
GL/GLX-775 10.0 10.5 10.75 11.75 12.0 13.0
VEIWING OUTSIDE
DIAMETER DIAMETER
NOTE: Hinge 4 & 9 are single hinge and two
required per enclosure.
• Hinge 10L-10R-11L-11R include two hinges
• Hinge 10L & 11L are for mounting on left side
of enclosure
• Hinge 10R & 11R are for mounting on right
side of enclosure
• All hinges supplied with stainless steel
mounting screws and pins
Note: For spacing less than minimum in table, (shown in inches) consult factory.
HINGE 4 & 9 Stainless Steel
HINGE-10L and HINGE-10R
HINGE-11L and HINGE-11R
Extruded Aluminum
GLXR RECTANGULAR LENS COVER ASSEMBLIES
GLXR RECTANGULAR
GLASS LENS COVERS
Applications
Rectangular glass lens windows can
be factory installed to enable viewing
of digital read out meters and devices
such as:
Volt meters
Flow meters
Gas analyzers
Process receivers, transmitters
and controllers
Ordering Information
Rectangular lens option must be facto-
ry installed and ordered in conjunction
with appropriate EXB Series enclosure.
See page E19. Submit drawing or
sketch to specify lens location. Consult
factory for multi-lens arrangements.
CATALOG
NUMBER
GLXR13
GLXR24
GLXR27
GLXR34
GLXR36
GLXR47
GLXR59
GLXR99
VIEWING AREA MINIMUM SPACE
A
1"
2"
2"
3.5"
3"
4"
5"
9"
OTHER DIMENSIONS
B
3"
4"
7"
4"
6"
7"
9"
9"
C
4.5"
5.5"
5.5"
7"
6.5"
7.5"
8.5"
12.5"
D
6.5"
7.5"
10.5"
7.5"
9.5"
10.5"
12.5"
12.5"
E
.5"
1"
1"
1.75"
1.5"
2"
2.5"
4.5"
F
1.5"
2"
3.5"
2"
3"
3.5"
4.5"
4.5"
G
2.25"
2.75"
2.75"
3.5"
3.25"
3.75"
4.25"
6.25"
H
3.25"
3.75"
5.25"
3.75"
4.75"
5.25"
6.25"
6.25"
ENCLOSURE OPTIONS ENCLOSURES
GLASS LENS COVERS E19
FEATURES-SPECIFICATIONS
E
GLXR LAYOUT GUIDE
CATALOG NUMBER Z = MAXIMUM CENTER LINE OF COVER TO CENTERLINE OF GLASS LENS
USEABLE COVER AREA
XYGLXR13 GLXR24 GLXR27 GLXR34 GLXR36 GLXR47 GLXR59 GLXR99
EXB-664 N34 5" 5 " NN NNNNN N
EXB-886 N34 7" 7" 1-1/4" 3/4" NN NNN N
EXB-8104 N34 7" 9" 2-1/4" 1-3/4" N 1" NN NN
EXB-8106 N34 7" 9" 2-1/4" 1-3/4" N 1" NN NN
EXB-8126 N34 7" 11" 3-1/4" 2-3/4" R • 2" R • NNN
EXB-8128 N34 7" 11" 3-1/4" 2-3/4" R • 2" R • NNN
EXB-10106 N34 9" 9" 2-1/4" 1-3/4" N 1" NN NN
EXB-10108 N34 9" 9" 2-1/4" 1-3/4" N 1" NN NN
EXB-10146 N34 9" 13" 4-1/4" 3-3/4" R 3" RR R N
EXB-10148 N34 9" 13" 4-1/4" 3-3/4" R 3" RR RN
EXB-12126 N34 10" 10" 2-3/4" 2-1/4" 2-1/4" 1-1/2" 1-3/4" 1-1/4" N N
EXB-12128 N34 10" 10" 2-3/4" 2-1/4" 2-1/4" 1-1/2" 1-3/4" 1-1/4" NN
EXB-12186 N34 10" 16" 5-3/4" 5-1/4" 5-1/4" 4-1/2" 4-3/4" 4-1/4" R N
EXB-12188 N34 10" 16" 5-3/4" 5-1/4" 5-1/4" 4-1/2" 4-3/4" 4-1/4" R N
EXB-12246 N34 10-1/4" 22-1/4" 8-7/8" 8-3/8" 8-3/8" 7-5/8" 7-7/8" 7-3/8" RN
EXB-12248 N34 10-1/4" 22-1/4" 8-7/8" 8-3/8" 8-3/8" 7-5/8" 7-7/8" 7-3/8" RN
EXB-122412 N34 10-1/4" 22-1/4" 8-7/8" 8-3/8" 8-3/8" 7-5/8" 7-7/8" 7-3/8" RN
EXB-12368 N34 11" 35" 15-1/4" 14-3/4" 14-3/4" 14" 14-1/4" 13-3/4" R N
EXB-123610 N34 11" 35" 15-1/4" 14-3/4" 14-3/4" 14" 14-1/4" 13-3/4" R N
EXB-14146 N34 13" 13" 4-1/4" 3-3/4" 3-3/4" 3" 3-1/4" 2-3/4" 2-1/4" *
EXB-14148 N34 13" 13" 4-1/4" 3-3/4" 3-3/4" 3" 3-1/4" 2-3/4" 2-1/4" *
EXB-16166 N34 14" 14" 4-3/4" 4-1/4" 4-1/4" 3-1/2" 3-3/4" 3-1/4" 2-3/4" 3/4"
EXB-16168 N34 14" 14" 4-3/4" 4-1/4" 4-1/4" 3-1/2" 3-3/4" 3-1/4" 2-3/4" 3/4"
EXB-16248 N34 14" 22" 8-3/4" 8-1/4" 8-1/4" 7-1/2" 7-3/4" 7-1/4" 6-3/4" 4-3/4"
EXB-162410 N34 14" 22" 8-3/4" 8-1/4" 8-1/4" 7-1/2" 7-3/4" 7-1/4" 6-3/4" 4-3/4"
EXB-18186 N34 16" 16" 5-3/4" 5-1/4" 5-1/4" 4-1/2" 4-3/4" 4-1/4" 3-3/4" 1-3/4"
EXB-18188 N34 16" 16" 5-3/4" 5-1/4" 5-1/4" 4-1/2" 4-3/4" 4-1/4" 3-3/4" 1-3/4"
EXB-18248 N34 16" 22" 8-3/4" 8-1/4" 8-1/4" 7-1/2" 7-3/4" 7-1/4" 6-3/4" 4-3/4"
EXB-182410 N34 16" 22" 8-3/4" 8-1/4" 8-1/4" 7-1/2" 7-3/4" 7-1/4" 6-3/4" 4-3/4"
EXB-18308 N34 16" 29" 12-1/4" 11-3/4" 11-3/4" 10" 11-1/4" 9-3/4" 9-1/4" 8-1/4"
EXB-18368 N34 16" 34" 14-3/4" 14-1/4" 14-1/4" 12-1/2" 13-3/4" 12-1/4" 11-34" 10-3/4"
EXB-183610 N34 16" 34" 14-3/4" 14-1/4" 14-1/4" 12-1/2" 13-3/4" 12-1/4" 11-34" 10-3/4"
EXB-203611 N34 18-7/8" 34-7/8" 15-3/16" 14-11/16" 14-11/16" 13-15/16" 14-3/16" 13-11/16" 13-3/16" 11-3/16"
EXB-24248 N34 22" 22" 8-3/4" 8-1/4" 8-1/4" 7-1/2" 7-3/4" 7-1/4" 6-3/4" 4-3/4"
EXB-242410 N34 22" 22" 8-3/4" 8-1/4" 8-1/4" 7-1/2" 7-3/4" 7-1/4" 6-3/4" 4-3/4"
EXB-24308 N34 22" 28" 11-3/4" 11-1/4" 11-1/4" 9-1/2" 10-3/4" 9-1/4" 9-3/4" 7-3/4"
EXB-24368 N34 22" 34" 14-3/4" 14-1/4" 14-1/4" 12-1/2" 13-3/4" 12-1/4" 12-3/4" 10-3/4"
EXB-243610 N34 22" 34" 14-3/4" 14-1/4" 14-1/4" 12-1/2" 13-3/4" 12-1/4" 12-3/4" 10-3/4”
Symbols: N = Enclosure will not accommodate this lens size
R = Rotate lens 90°, consult factory for layout assistance
• = Voids UL/CSA/CENELEC certifications
* = Indicates center line
ENCLOSURE OPTIONS ENCLOSURES
DRAINS/BREATHERS/FLAME ARRESTORS
E20
IEC Ex CSA 10.0007u
Certified - File LR11716
KDB-1 KB1B KB1D
Listed - File E10514
IEC Ex CSA 10.0007u
Certified - File LR11716
Certified File 25215
FM
APPROVED
Class I, Div. 1 & 2, Groups B1,C,D
Class I, Zones 1 & 2, Groups IIB + H21
Class II, Div. 1 & 2, Groups E,F,G
Class III, NEMA Type 3
II 2 G Ex d IIB IIC2T226C Gb IP44
1See chart below for
suitability
2Warning - not for use
in acetylene atmosphere
NEW OPTIONS
NEW LISTINGS
ATEX PENDING
4/2011
TYPICAL INSTALATION
1See chart below for suitability
2Warning - not for use in acetylene
atmospheres
2
2
ATEX PENDING 4/2011
Class I, Div. 1 & 2, Groups B1,C,D
Class I, Zones 1 & 2, Groups IIB + H21
Class II, Div. 1 & 2, Groups E,F,G
Class III, NEMA Type 3, 41
II 2 G Ex d IIB IIC2T3 Gb IP661
7/8"
2.96"
KB SERIES FLAME ARRESTOR
KB/KD SERIES DRAIN &
BREATHERS
Applications
When installed in the top of an enclo-
sure, these fittings act as breathers
which allows air flow through the
Applications
The flame arrestor provides a means
to connect gas analysis equipment
and electro pneumatic devices' pipe
or tubing system through the wall of
an explosion-proof enclosure.
BODY MATERIAL: 6061--T6 series alu-
minum provided as standard. Optional
stainless steel or brass for special
orders.
enclosure. Bottom installations permit
water from condensation to drain from
the enclosure continuously. The
drains and breathers are offered in a
variety of hub sizes, 1/4, 3/8 & 1/2
inch NPT and metric M16 & M20.
Body Material
Aluminum with optional stainless steel
or brass available for special orders.
Volume
For use in enclosures with a maximum
internal volume to 9526 cubic inches
or 160 liters.
Specifications
Air flow = 83 + 15 / -25 SCFH at 5PSI
Pressure drop = 1.3 PSI at 100 PSI
Maximum flow pressure = 800 PSI
Volume = For use in enclosures with
a maximum internal volume of 9526
cubic inches or 160 liters.
NEW!
CBH SERIES ENCLOSURES
CIRCUIT BREAKER HANDLES E21
FEATURES-SPECIFICATIONS
E
EXH CIRCUIT BREAKER HANDLE WITH SHAFT AND PAN
CBH CIRCUIT BREAKER HANDLES
For use with enclosure type
B7E-DB-EXB-XJB
Used to activate circuit breakers and
motor circuit protectors from front
cover
Factory or field installed in a 3/4"
NPSM opening for EXH1 & EXH2 and
a 1-1/4" NPSM for EXH3
Has provision for Lock-On and
Lock-Off with up to three padlocks
Consists of an external handle mech-
anism with through-the-enclosure
shaft and internal toggle mechanism
and breaker pan
Submit sketch showing the desired location of
internal breaker for factory location of handle
mechanism.
Order as separate option with enclosure for fac-
tory installation or by Catalog Number for field
installation.
Consult factory for handle mechanism for fused
and non-fused disconnect switches.
Circuit Breaker Handles
BREAKER
MANUFACTURER
CATALOG NUMBER
BREAKER FRAMES
TO OPERATE
MAX.
AMPS
6" DEEP BOX 8" DEEP BOX
CATALOG NUMBER
10" DEEP BOX
GE
ITE/Siemens
Square D
Cutler Hammer
GE
Square D
Cutler Hammer
Cutler Hammer
GE
ITE/Siemens
ITE/Siemens
ITE/Siemens
Square D
Cutler Hammer
GE
ITE/Siemens
ITE/Siemens
Square D
Square D
Cutler Hammer
TEB-TED-THED-TEL
ED2-ED4-ED6-HED4-HED6
FAL-FHL-FCL
EHD-FDB-FD-HFD-FDC-HMCP
TFJ-TFK-THFK-TFL
KAL-KHL-KCL
JDB-JD-HJD-JDC
DK-KDB-KD-HKD-KDC
TJJ-TJK4-TJK6-THJK4-THJK6
FXD6-FD6-HFD6-CFD6
JXD2-JXD6-JD6-HJD6-HHJD6-CJD6
LXD6-LD6-HKD6-HHLD6-CLD6
LAL-LHL
LDB-LD-HLD-LDC
TKM8-THKM8-TKM12-THKM12
MXD6-MD6-HMXD6-HMD6-CMD6
NXD6-ND6-HNXD6-HND6-CND6
LCL
MAL-MHL
ND-HND-NDC
150
125
100
150
225
250
250
400
600
250
400
600
400
600
1200
800
1200
600
1000
1200
EXH1A6
N/A
N/A
N/A
N/A
EXH1A8
EXH1B8
EXH2C8
EXH3D8
N/A
EXH1A10
EXH1B10
EXH2C10
EXH3D10
EXH3E10
Applications
CBH Series circuit breaker handles
are for use with the following Series
of Killark enclosures: XJB, DB.
These devices may be used to acti-
vate circuit breakers, motor circuit
protectors, and nonfusible discon-
nects
Complete handle mechanisms
include external handle and lockout,
internal switching mechanism, and
adjustable shaft
Consult factory for installation data,
and hazardous location suitability
CIRCUIT BREAKER
FRAME TYPE
COMPLETE MOUNTING
ASSEMBLY1PAN2FOR 6" FOR 8" FOR 12" FOR 20"
DEEP BOX DEEP BOX DEEP BOX DEEP BOX
EHD, FDB, FD, HFD,
FDC,HMCP-150
CBH-114 CBH-1P
CBH-118 CBH-1P FAL, FHL
30, 60 Amp
N.F. Switch
CBH-120 CBH-1P
DK, KDB, KD,HKD,
KDC, HMCP-400
CBH-213 CBH-3P
CBH-216 CBH-3P JDB, JD, HJD, JDC,
HMCP-250
CBH-6S CBH-8S CBH-12S CBH-20S
CBH-6S CBH-8S CBH-12S CBH-20S
CBH-6S CBH-8S CBH-12S CBH-20S
CBH-6S CBH-8S CBH-12S CBH-20S
CBH-6S CBH-8S CBH-12S CBH-20S
1CBH-114 thru CBH-120 provided with CBH-6S shaft. CBH-213 thru CBH-216 provided with CBH-8S shaft.
2Breaker mounting pan is not included in complete assembly.
SHAFT
CUTLER HAMMER SQUARE D
EXH
CBH
TBWE SERIES ENCLOSURES
ENCLOSURE OPTIONS
FEATURES-SPECIFICATIONS
600 Volt –#8–#22 CU; #8–#12 AL.
50 Amp Maximum
Applications
Mounting in EXB, XJB, GR, DB Series
junction boxes.
Use in connecting and in arrange-
ment of control wiring for control
panel and switchboard applications
Features
Terminal blocks have clamping screw-
type terminals which accommodate
either aluminum or copper wire. TMS
marking strips are included.
When more than one terminal strip is
required, a mounting pan should be
used for ease of mounting and wiring
C = .625 + (1.3125 x N)
L = 1.250 + (1.3125 x N)
N = NUMBER OF BLOCKS
External Control Operators
Custom control panels possible by
factory or field installation of Killark
“G” series control operators
Select from a wide variety of push
buttons, pilot-lights, selector switches,
potentiometer operators and motor
shaft rotary operators
Refer to catalog pages C31 - C36 for
operator selection
Cutler Hammer TypeTBA Modular Terminal Blocks
600 Volt-#8–#22 CU.; #8-#12 AL.
Clamping Screw Type Terminals, Type TMS Marking Strip Included
TBWE TERMINAL BLOCKS
CATALOG NO. OF DIMENSIONS
NUMBER CIRCUITS ACL
TBWE-3 3 1.25 1-7/8" 2-1/2"
TBWE-6 6 2.50 3-1/8" 3-3/4"
TBWE-9 9 3.75 4-3/8" 5"
TBWE-12 12 5.0 5-5/8" 6-1/4"
TBWE-15 15 6.25 6-7/8" 7-1/2"
TBWE-18 18 7.50 8-1/8" 8-3/4"
TBWE-21 21 8.75 9-3/8" 10"
TBWE-24 24 10.0 10-5/8" 11-1/4"
TBWE-27 27 11.25 11-7/8" 12-1/2"
TBWE-30 30 12.50 13-1/8" 13-3/4"
TBWE-33 33 13.75 14-3/8" 15"
TBWE-36 36 15.0 15-5/8" 16-1/4"
TBWE-39 39 16.25 16-7/8" 17-1/2"
TBWE-42 42 17.5 18-1/8" 18-3/4"
TBWE-45 45 18.75 19-3/8" 20"
TBWE-48 48 20.0 20-5/8" 21-1/4"
TBWE-51 51 21.25 21-7/8" 22-1/2"
TBWE-54 54 22.50 23-1/8" 23-3/4"
TBWE-57 57 23.75 24-3/8" 25"
TBWE-60 60 25.0 25-5/8" 26-1/4"
Terminal Block
External Control Operators
(See Pages C31-C36)
E22
GR SERIES ENCLOSURES
THREADED ENCLOSURES E23
FEATURES-SPECIFICATIONS
E
Applications
Hazardous locations due to the pres-
ence of flammable gases or vapors,
combustible dusts or easily ignitable
fibers or flyings, and areas which are
subject to corrosion, weather and
dampness
Installations at petroleum refineries,
chemical and petrochemical plants,
storage areas, and other processing
facilities where hazardous sub-
stances are handled or stored
Applications requiring junction, pull
and/or splice boxes
Enclosures to house meters, relays,
terminal strips, control transformers,
etc.
#UL886 - Outlet Boxes and Fittings for use in
Hazardous (Classified) Locations. File
#E10514
#UL1203 - Explosion Proof and Dust Ignition
Proof Electrical Equipment.
File #E83969
#C22.2 No. 30-M1986 - Explosion Proof
Enclosure for use in Class I Hazardous
Locations. File #LR11716
CENELEC II 2 G/D
PTB 02 ATEX 1071U (Empty Housing)
PTB 02 ATEX 1072 (Enclosure with Controls)
IEC Ex PTB 05 0029
IEC Ex 50 0028U
FM
APPROVED
#3600 & 3615 File #2Y4A5.AE
Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones 1 & 2, Groups IIB+H2, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D), 9(E,F,G)
CENELEC/ATEX/IEC Ex
Exd IIC T6 or T5
IP66 T80°C or T90°C
Ex d IIC T6 or T5
Ex tD A21 IP66 T80°C or T90°C
Features
Compact square or rectangular
enclosures with threaded screw type
covers provide easy access to interior
Can be shipped in component parts
and still maintain third party UL-CSA-
FM approvals
Available in three different cover types,
flat blank, lens and dome covers
Cast mounting lugs are standard on
all assemblies
Available as blank box or can be
custom drilled and tapped for con-
duit openings which may be factory
or field installed on the four sides or
back wall
Gaskets are standard on all assem-
blies and with covers when compo-
nent part ordering
Internal ground screw supplied on
all boxes
CEN suffix modification for CEN-
ELEC Certification includes an exter-
nal ground screw, cover locking
screw, and nameplate displaying cer-
tification and area classifications.
Feature is only available on complete
assemblies and not available when
component part ordering.
Material/Finish
Enclosures:
Copper-free Aluminum (less than
4/10 of 1%)
Optional Mounting Pans:
Sheet Aluminum
Lens Cover Glass:
Tempered soda lime glass
Cover Gaskets:
GRB, GRE, GRM, GRK, GRL
70 Durometer NITRILE
GRH, GRHA, GRHC
57 63 Durometer BUNA-N
Electrostatically applied gray powder
epoxy/polyester finish on exterior of
box and cover
Global applications* (ATEX)
Enclosures are available for
global applications with “CEN”
suffix. Assemblies that are modi-
fied to CENELEC/ATEX stan-
dards maintain their North
American certifications.
ATEX / IEC Ex Certified
GR COMPONENT PARTS
GR SERIES ENCLOSURES
THREADED ENCLOSURES
E24
FEATURES-SPECIFICATIONS
NOTE: See Page E23 for Third Party Certifications
GR COMPLETE ASSEMBLIES
CATALOG NUMBER OF COMPONENTS
3-29/32"
4-11/32"
5-9/32"
7-1/4"
7-7/8"
9-5/8"
9-5/8"
9-5/8"
GRB-275L
GRE-300L
GRM-375L
GRK-537L
GRL-600L
GRH-775L
GRHC-775L
GRHA-775L
2-3/4"
3"
3-3/4"
5-3/8"
6"
7-3/4"
7-3/4"
7-3/4"
2"
4"
3"
5"
4"
4"
8"
4"
8"
4"
8"
1-1/2"
2"
2"
2-1/2"
2"
4"
4"
4"
4-5/8" 4-5/8" 4-5/32"
6-5/8" 5-1/2" 5-1/4"
6-7/8" 6-7/8" 5-15/16"
9-7/8" 8-3/8" 6-17/32"
10-1/2" 8-7/8" 7-3/16"
12" 11" 7-5/8"
12-3/16" 11" 11"
12" 11" 16-3/16"
COVER
OPENING
DIAMETER BOX WITH
BLANK COVER
BOX WITH
LENS COVER
BOX WITH
DOME COVER
DEPTH OF
DOME
MAXIMUM
CONDUIT SIZE
VIEWING
AREA
CATALOG NUMBER
NOMINAL EXTERNAL BOX
DIMENSIONS WITHOUT
COVER
LWD
2GRB
4GRB
3GRM
5GRM
4GRK
4GRH
8GRH
4GRHC
8GRHC
4GRHA
8GRHA
NOTE: To order above items with CENELEC Modifications and Certifications add suffix CEN to end of catalog number. (Example: GRBCEN)
To order above items with a flat back pan installed add suffix P to catalog number.
NOTES: Covers are supplied with gasket.
For Group B locations all conduits must be sealed within 18" of enclosures.
ENCLOSURE
SERIES
GRB
GRE
GRM
GRK
GRL
GRH
GRHC
GRHA
BOX WITHOUT
COVER
GRBB
GREB
GRMB
GRKB
GRLB
GRHB
GRHCB
GRHAB
BLANK COVER
GRB-BC
GRE-BC
GRM-BC
GRK-BC
GRL-BC
GRH-BC
GRH-BC
GRH-BC
LENS COVER
GL-275
GL-300
GL-375
GL-537
GL-600
GL-775
GL-775
GL-775
DOME COVER
2"- 2GRBD
4"- 4GRBD
3"- 3GRMD
5"- 5GRMD
4"- 4GRKD
4"- 4GRHD
8"- 8GRHD
4"- 4GRHD
8"- 8GRHD
4"- 4GRHD
8"- 8GRHD
GASKET
REPLACEMENT
GRB-RG
GRE-RG
GRM-RG
GRK-RG
GRL-RG
GRH-RG
GRH-RG
GRH-RG
FLAT PAN
6086PAN
6074
6064
6038
6053
6058
6058
6058
CATALOG NUMBER
Box with lens cover
Box with blank cover Box with dome cover
GRB
GRE
GRM
GRK
GRL
GRH
GRHC
GRHA
DIMENSIONS
FOR MTG. PANS
3.5” x 3.5”
4” x 4.5”
5” x 5
5.5” x 7.5”
6” x 8.5”
8” x 9
GR SERIES ENCLOSURES
THREADED ENCLOSURES E25
E
GR ENCLOSURE VOLUMES
GR MODIFICATIONS Drilled & Tapped Conduit Openings
Boxes are furnished blank for field
drilling and tapping of conduit openings.
If factory openings are requested
submit drawing or select from charts
below.
SIZE
1/2"
3/4"
1"
1-1/4"
1-1/2"
2"
2-1/2"
3"
3-1/2"
4"
SYMBOL
1
2
3
4
5
6
7
8
9
10
SYMBOL NUMBER
EXAMPLE: GRB-C3-J2-P1=
GRB enclosure with 1" NPT top center,
3/4" NPT right side center,
1/2" NPT bottom center
DESCRIPTION
Drain and breather
NEMA 3,7CD,9EFG
Drain and breather
NEMA 3,7BCD,9EFG
Internal flat mounting pan
installed
CENELEC modification and
certification (complete box &
cover assembly only)
Drill for pan mounting studs
without pan
Removal of external
mounting lugs
SUFFIX
NUMBER
SU3
SU3B
P
CEN
SU8
SU6
Installation of drain and breather will
void NEMA 4-4x ratings
SU3/SU3B are not CENELEC
approved
SU3B not CSA
Contact Killark for CENELEC drain
and breather requirements
CATALOG VOL.
NUMBER (CU. IN.)
GRB 45
GRE 105
GRM 180
GRK 305
GRL 405
GRH 615
GRH A 1450
GRH C 985
GRB-275L 40
GRE-300L 95
GRM-375L 170
GRK-537L 280
GRL-600L 380
GRH-775L 570
GRHA-775L 1400
GRHC-775L 940
2GRB 60
4GRB 80
3GRM 225
5GRM 250
4GRK 410
4GRH 820
8GRH 1050
4GRHA 1660
8GRHA 1890
4GRHC 1195
8GRHC 1425
GRB 4" 6" 5/16" 4-5/8" 4-5/8" 4-5/32" 3-29/32"
GRE 5-3/4" 6-1/2" 5/16" 6-5/8" 5-1/2" 5-1/4" 4-11/32"
GRM 5-7/8" 8-1/8" 5/16" 6-7/8" 6-7/8" 5-15/16" 5-9/32"
GRK 9-1/8" 9-5/8" 5/16" 9-7/8" 8-3/8" 6-17/32" 7-1/4"
GRL 9-1/2" 10-1/2" 7/16" 10-1/2" 8-7/8" 7-3/16" 7-7/8"
GRH 10-3/4" 12-1/8" 7/16" 12" 11-5/8" 7-5/8" 9-5/8"
GRHA 8-1/4" 12-1/8" 7/16" 12" 11-5/8" 16-3/16" 9-5/8"
GRHC 8-1/4" 12-1/8" 9/16" 12-3/16" 11-5/8" 11" 9-5/8"
CAT.
NO. A B C DEF G* HIJKL+M
4-9/16" 4-17/32" 3-3/4" 3-3/4"
5-3/4" 5-23/32" 4-5/8" 5-3/4"
6-9/16" 6-9/16" 6" 6"
7-9/32" 7-3/16" 7-1/16" 8-5/16"
7-31/32" 7-15/16" 7-5/8" 9-1/8"
8-3/8" 8-5/8" 9-1/2" 10-1/2"
16-15/16" 16-3/16" 9-1/2" 10-1/2"
11-3/4" 12" 9-9/16" 10-5/8"
2-11/16" 2-3/4"
3-9/32" 3"
4-3/16" 3-3/4"
4-1/8" 5-3/8"
4-15/16" 6"
5" 7-3/4"
13-9/16" 7-3/4"
8-7/16" 7-3/4"
NOTE: GRH has four lugs with holes. GRHA & GRHC has four lugs with slots.
* Box Opening
+ Lens Viewing
Dimensions
CATALOG NUMBER
BASIC BOX W/DOME COVER S
2GRB 7"
4GRB 9"
3GRM 10-1/4"
5GRM 12-1/4"
4GRK 11-15/16"
4GRH 13"
8GRH 17"
4GRHA 21-1/2"
8GRHA 25-1/2"
4GRHC 16-5/16"
8GRHC 20-5/16"
GRB
GRE
GRM
Blank Cover Lens Cover Dome Cover
GRK
GRL
GRH
GRHA
GRHC
S
INTERNAL
GR SERIES ENCLOSURES
INSTRUMENT ENCLOSURES
E26
FEATURES-SPECIFICATIONS
GR INSTRUMENT ENCLOSURES (INSTRUMENTS NOT SUPPLIED)
Applications
Use GR Series Instrument Enclosures for
mounting of 3", 3-1/2", 4" or 4-1/2" round
or rectangular instruments such as
ammeters and voltmeters
Two 3/4"-14 NPT drilled and tapped
conduit openings, one top and one
bottom, are standard
Internal mounting pan is attached to
inside back of box with spacers for
mounting meter
#3600 & 3615 File #2Y4A5.AE
FM
APPROVED
Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones 1 & 2, Groups llB+H2, llA
Class ll, Div. 1 & 2, Groups E,F,G
Class Ill, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D), 9(E,F,G)
CATALOG INSTRUMENT
NUMBER MANUFACTURER
MODEL SIZE TYPE
1930 Series 3-1/2" Rectangular
GRM-375L52 Weston 301 Series 3" Rectangular
301 Series 3-1/2" Round
GRM-375L52 General Electric KT w/o reset 3" Rectangular
KT w/o reset 3-1/2" Round
R-351 3" Rectangular
GRM-375L52 Cutler Hammer B-351 w/o reset 3" Rectangular
N-351 3-1/2" Round
27,27T,37,47, 57,77 Series 3" Rectangular
2100 Series 3-1/2" Rectangular
25,25T,35,45,55 Series 3-1/2" Round
GRM-375L52 Simpson 55ET 3-1/2" Round
75 3-1/2" Round
1300 Series 3-1/2" Rectangular
3223 3-1/2" Round
3323 3-1/2" Rectangular
GRM-375L52 Cutler Hammer N-371 Series 4-1/2" Round
GRK-537L52A Cutler Hammer R-371 Series 4" Rectangular
GRK-537L52A Simpson 3224 4-1/2" Round
250,162, 167,251 Series 3-1/2" Rectangular
178 Series 4-1/2" Rectangular
GRK-537L52A General Electric 171 Series 4-1/2" Rectangular
frequency meter
236 w/o Reset 3-1/2" Rectangular
GRK-537L52B Weston 1940 Series 4-1/2" Rectangular
AB/DB-30 4-1/2" Rectangular
GRK-537L52B General Electric AC ammeter
AB/DB-30 4-1/2" Rectangular
AC/DC ammeter
GRL-600L52B General Electric AB/DB-40 4-1/2" Rectangular
AC ammeter
DB-40 4-1/2" Rectangular
DC ammeter
GRK-537L52B General Electric DB-40 4-1/2" Rectangular
DC voltmeter
171,250, 251 Series 4-1/2" Rectangular
GRL-600L52C Simpson 29,29T,39,49,59,
79,1300,2100 Series 4-1/2" Rectangular
GRH-775L52B General Electric AB/DB-40 4-1/2" Rectangular
AC voltmeter
#UL1203 - Explosion Proof and Dust Ignition
Proof Electrical Equipment. File #E83969
#C22.2 No. 30-M1986 -Explosion Proof
Enclosure for use in Class I Hazardous
Locations. File #LR11716
GR SERIES ENCLOSURES
INSTRUMENT ENCLOSURES E27
FEATURES-SPECIFICATIONS
E
GR DIMENSIONS
CATALOG FIG.
NUMBER NO. ABCDE G H I
GRM-375L52 1 5-7/8" 8-1/8" 5/16" 6-7/8" 6-7/8" 3-9/16" 6-13/32" 2-5/8"
GRK-537L52A 1 9-1/8" 9-1/8" 5/16" 9-7/8" 7-7/8" 4-7/8" 6-11/16" 2-1/2"
GRK-537L52B 1 9-1/8" 9-1/8" 5/16" 9-7/8" 7-7/8" 4-7/8" 6-11/16" 2-1/2"
GRL-600L52B 1 9-1/2" 10-1/2" 7/16" 10-1/2" 8-7/8" 5-13/16" 7-17/32" 2-3/4"
GRL-600L52C 1 9-1/2" 10-1/2" 7/16" 10-1/2" 8-7/8" 5-13/16" 7-17/32" 2-3/4"
GRH-775L52B 2 10-3/4" 12-1/8" 7/16" 12" 11" 7-7/16" 8-3/4" 3"
Figure 2Figure 1
Dimensions
G DIA. G DIA.
C DIA.
C DIA.
E28
FEATURES-SPECIFICATIONS
HK/2HK SERIES ENCLOSURES
INSTRUMENT/DEVICE ENCLOSURES
Applications
Instrumentation housed in HK Series
enclosures typically used to measure,
detect, monitor, transmit and control
industrial processes and systems.
HK Series enclosures are suitable for a
broad range of applications, meeting
both domestic and international code
requirements.
Some specific examples of the type of
instruments that can be housed in
these enclosures include:
Flow measurement devices
Temperature monitors
Two-wire transmitters
Gas detectors
Ph analyzers
Pressure gauges
Temperature transmitters
Oxygen/combustible gas sensors
Methane gas monitors
Level detectors
H2S monitors
Transducers
Pressure switches
See pages E30 and E31 for
dimensions.
Certified - File LR11716
File 1W1R4-RE
ATEX Certificate:
DEMCO 01 ATEX 015742U (Enclosure Only)
FM
APPROVED
HK 2HK
Class I, Div. 1 & 2, Groups A*,B,C,D†
Class I, Zones 1 & 2, Groups llB + H2, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
CENELEC/ATEX - Ex d IIC IP66**
Ta< +60OC
Features
Enclosures are explosion proof,
dust/ignition proof, weather proof
and tamper resistant
HK Series boxes covers are cast
from a copper-free aluminum alloy
Cast stainless steel box, flat & lens
cover available (HKSB-BC + HKSB-
GLC)
Neoprene 0-rings are provided with
HK boxes to assure water resis-
tance in NEMA 4/IP66 conditions
Two box styles available: HKB single
cover design and the 2HKB double
cover design. 2HKB enclosure has
two separate chambers for isolation
between power and instrument.
HKB box has offset feed-thru conduit
openings (3/4" NPT) for maximum
use of interior volume
2HKB box has offset feed-thru con-
duit openings (3/4" NPT ) on power
side and one (3/4" NPT) on bottom
instrument side
Interior mounting pad for instru-
ment/device cast into the bottom
of the HKB box is provided in an “X”-
configuration for flexibility
Location of the internal ground screw
boss does not interfere with the
mounting of the instrument or device
Six different cover styles are avail-
able: standard flat cover, standard
glass lens cover,1" dome lens cover,
2" dome cover, 2" glass lens dome
cover and 4" dome cover
All covers have shrouded tamper
resistant set screws as standard
which can help to combat excessive
vibration in rugged settings
Lugs on cover permit easy removal
and tightening
Material/Finish
Boxes and covers — Copper-free
aluminum (less than 4/10 of 1%)
HKSB series is 316 cast stainless
steel
O-ring sealing gasket — Neoprene
rubber
Ground screws — zinc plated steel
with green dye (Stainless steel on
HKSB)
Allen head cover screw — cadmium
plated steel (Stainless steel on
HKSB)
Glass lens — 3/8" thick tempered
glass
Finish — silver powder epoxy paint,
electrostatically applied
Special colors available in quantity
* Group A FM only on HK single cover box.
Order with -GA suffix.
**CENELEC on assembled HK parts only with
suffix “C”.
Seal within 18" of enclosure for Groups BCD and
within 6" for Group A in accordance with sections
501-5 and 502-5 of the National Electrical Code.
Male threaded
box opening
3-1/2" dia.
Optional
external
ground
screw
External
mounting
lugs cast
as standard
O-ring sealing gasket is
included standard with box
Internal ground
screw provision
standard
“X” configured
cast-in
mounting pad
Location
for optional
back hub
Offset, feed thru
conduit openings
3/4" NPT
Access to
power
opening
Power side
male threaded
box opening
3-1/2" dia.
Ground screw standard
for internal use
Two O-ring
sealing gas-
kets included
standard
with box
Power side offset lead-thru conduit
opening 3/4" NPT
2HK Design Features
Cast on side boss for
optional machining Instrument
side male
threaded
box opening
3-1/2" dia.
Location
for optional
external
ground screw
Instrument
side conduit
opening
3/4" NPT
HK Design Features
ATEX Certified
Classified - File E83969
& File E150827
HK/2HK SERIES ENCLOSURES
INSTRUMENT/DEVICE ENCLOSURES E29
FEATURES-SPECIFICATIONS
E
HKSB STAINLESS STEEL ASSEMBLED PARTS23
HK ASSEMBLED PARTS23
NOTE: See page E28 for Third Party
Certification
Factory Modifications
Approvals allow for factory or field
modifications on HKB box for drilling
and tapping conduit openings on side
or back of enclosure without voiding
UL-CSA-FM approvals. Internal mount-
ing pad holes on “X” configured boss
can be factory added by drilling from
inside of box without piercing the bot-
tom of enclosures. Assemblies with
CENELEC approvals must be factory
modified in order to comply with
certifications.
HKB FACTORY MODIFICATIONS
OPTIONAL FACTORY MACHINING (HKB)
CATALOG SUFFIX DESCRIPTION
-01 - 1/2 NPT hub in back
-02 - 3/4 NPT hub in back
-10 - 1/2 NPT hub in side
-20 - 3/4 NPT hub in side
-21 - 3/4 NPT hub in side
1/2 NPT hub in back
-22 - 3/4 NPT hub in side
3/4 NPT hub in back
-02S - 3/4 NPSM hub in back
-22S - 3/4 NPT hub in side
3/4 NPSM hub in back
-2S2S - 3/4 NPSM hub in side
3/4 NPSM hub in back
-2S0 - 3/4 NPSM hub in side
-2S1 - 3/4 NPSM hub in side
1/2 NPT hub in back
-2S2 - 3/4 NPSM hub in side
3/4 NPT hub in back
External ground screw
-GS (Standard on HKB
assembly with
CENELEC approvals)
Group A - FM approval
-GA - (Available only on HKB
box furnished with
covers installed)
-SU93 - Unpainted - Natural finish
Special colors of powder
-SU9 - paint available in quantity.
Consult factory for details
Ordering examples:
Modified box component HKB-20
Modified assembly HKB - B - 20 OR HKB - BC - 20
2HKB Series Boxes
The wall that separates the instrument
side from the power side can be
machined for slots or holes up to a
maximum of two slots 5/16" by 1-1/2".
Submit drawings for machining require-
ments to Killark.
2HKB
HK2GLD Lens HK4D Blank
2HKB-B-B
2HKB-B-2D
2HKB-B-4D
2HKB-B-GL
2HKB-B-2GLD
HKB-B HKB-BC
HKB-2D HKB-2DC
HKB-4D HKB-4DC
HKB-GL HKB-GLC
HKB-2GLD HKB-2GLDC
HKB BOX & COVERS
HKSB BOX & COVERS
CENELEC UL-CSA-FM
APPROVED
HKSB-BC
HKSB-GLC
CATALOG NUMBER (CAST ALUMINUM)
1Assemblies that are CENELEC approved include as standard:
• External ground screw with terminal
• Predrilled nameplate holes and screw on pad for customer installed nameplate.
2See information at right for optional factory machining.
3Product is stocked at component level. Recommend ordering as such for reduced lead time.
42HKB Assemblies include a flat cover on power side, dome and lens covers can be substituted in
place of flat cover, consult factory for ordering details.
5Not ATEX certified
2HKB BOX w / BLANK COVER on POWER SIDE &
OPTIONAL COVER on INSTRUMENT SIDE4
(UL-CSA-FM)
COVER TYPE
Standard flat
Lens
CENELEC
UL-CSA-FM
APPROVED¨
CENELEC UL-CSA-FM
APPROVED1
UL-CSA-FM
APPROVED
UL-CSA-FM
APPROVED
COVER
TYPE
Standard flat
2" Dome
4" Dome
Lens
2" Dome lens
2HKB-BC-BC
2HKB-BC-2DC
2HKB-BC-4DC
2HKB-BC-GLC
2HKB-BC-2GLDC
HKB
HKBD5
Boxes
HK COMPONENT PARTS
HKB
HKBD
2HKB
HFC
HKGL
HK1GLD*
HK2D
HK4D
HK2GLD
15722LABB
CATALOG NUMBER DESCRIPTION
Single cover box only
Single deep box only
Double cover Box only
Flat cover
Lens cover
1" Dome lens cover
2" Dome cover
4" Dome Cover
2" Dome lens cover
Rep. “O” Ring Gasket
Standard Flat Covers
HK2D Blank
Dome Covers 1", 2" and 4"
HKGL Lens
HFC Blank
HKB-BC HKSB-GLC
HK1GLD Lens
HKBD-B
HKBD-2D
HKBD-4D
HKBD-GL
HKBD-2GLD
HKBD BOX & COVERS
E30
FEATURES-SPECIFICATIONS
HK SERIES ENCLOSURES
INSTRUMENT/DEVICE ENCLOSURES
Dimensions
Note: Add 1/2 to all
depth dimensions when
using HKBD Deep Box.
HKBD volume
= 33 cu.in.
HKB Volume: 31 cu. in.
HKB box and blank cover
HKB box and glass lens cover
RAISED MOUNTING PAD FOR INSTALLATION OF
METERS OR DEVICES. MAXIMUM DRILLING DEPTH,
5/16" (7.94MM); MAXIMUM TAP DEPTH, 1/4" (6.35 MM);
MAXIMUM TAP SIZE, #10 NF OR NC OR ISO M 4 X 0.7
Flat Cover
Lens Cover
2" Dome Cover
2" Dome Lens Cover
4" Dome CoverFlat Cover
For HK1GLD (1” Dome
Lens Cover), add 1” to
lens cover verticle height
dimensions
HK 2HK
2HK SERIES ENCLOSURES
INSTRUMENT/DEVICE ENCLOSURES E31
FEATURES-SPECIFICATIONS
E
Dimensions
HKSB - Stainless Steel
E32 B7/DB/EXB/GR/XJB SERIES ENCLOSURES
CONDUIT OPENING DATA
EXB/XJB/DB/GR
MINIMUM CENTERS FOR DRILLED AND TAPPED OPENINGS AND UNION HUBS
EXB/XJB/DB/GR SYMBOL NUMBERS
Instructions
Drilled and tapped conduit openings
will be evenly spaced and located in
the area indicated on the location
chart. Critical conduit opening loca-
tions may be indicated by supplying
a diagram similar to the one shown at
right indicating critical dimensions and
locations. Specific conduit openings
must be located dimensionally from
box centerlines to conduit centerlines
and from outside back surface of box
to conduit centerline.
Ordering Information:
(1) Select the letter on location chart
which indicates conduit opening
position desired.
(2) Select symbol number from chart
which indicates conduit opening
type and size.
SIZE FORM 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 3-1/2" 4" 5" 6"
1/2" 1-3/16" ––––– – ––
1/2" 1-3/8" ––––– – ––
1/2" 1-5/8" ––––– – ––
3/4" 1-3/8" 1-1/2" ––––– – ––
3/4" 1-1/2" 1-5/8" ––––– – ––
3/4" 1-3/4" 1-13/16" ––––– – ––
1" 1-1/2" 1-3/4" 1-13/16" ––– – ––
1" 1-3/4" 1-7/8" 2" ––– – ––
1" 1-7/8" 2" 2-1/8" ––– – ––
1-1/4" 1-11/16" 1-15/16" 2-1/16" 2-5/16" ––– – ––
1-1/4" 1-15/16" 2-1/16" 2-1/4" 2-1/2" ––– – ––
1-1/4" 2-1/16" 2-1/4" 2-5/16" 2-1/2" ––– – ––
1-1/2" 1-15/16" 2-1/16" 2-3/16" 2-1/2" 2-5/8" –– –
1-1/2" 2-1/8" 2-1/4" 2-3/8" 2-5/8" 2-3/4" –– –
1-1/2" 2-3/16" 2-9/32" 2-7/16" 2-5/8" 2-3/4" –– –
2" 2-1/4" 2-3/8" 2-9/16" 2-13/16" 2-15/16" 3-3/16" –– – –
2" 2-3/8" 2-1/2" 2-3/4" 3" 3-1/8" 3-3/8" –– – –
2" 2-1/2" 2-19/32" 2-3/4" 3" 3-1/8" 3-3/8" –– – –
2-1/2" 2-7/16" 2-9/16" 2-3/4" 3" 3-1/8" 3-3/8" 3-5/8" –– –
2-1/2" 2-5/8" 2-3/4" 3" 3-1/4" 3-3/8" 3-5/8" 4" –– –
2-1/2" 3-1/8" 3-7/32" 3-3/8" 3-9/16" 3-11/16" 4" 4-5/8" –– –
3" 2-13/16" 2-15/16" 3-1/16" 3-5/16" 3-7/16" 3-3/4" 4" 4-5/16" ––
3" 3" 3-1/8" 3-3/8" 3-5/8" 3-3/4" 4" 4-3/8" 4-3/4" ––
3" 3-9/16" 3-21/32" 3-13/16" 4" 4-1/8" 4-7/16" 5-1/16" 5-1/2" ––
3-1/2" 3-1/8" 3-1/4" 3-3/8" 3-5/8" 3-3/4" 4-1/i6" 4-5/16" 4-5/8" 4-15/16" ––
3-1/2" 3-3/8" 3-1/2" 3-5/8" 3-7/8" 4" 4-3/8" 4-5/8" 5" 5-3/8" ––
3-1/2" 4" 4-3/32" 4-1/4" 4-7/16" 4-9/16" 4-7/8" 5-1/2" 5-15/16" 6-3/8" ––
4" 3-7/16" 3-9/16" 3-11/16" 3-15/16" 4-1/16" 4-3/8" 4-5/8" 4-15/16" 5-1/4" 5-9/16" ––
4" 3-3/4" 3-7/8" 4" 4-1/4" 4-3/8" 4-3/4" 5" 5-3/4" 5-5/8" 6" ––
4" 4" 4-3/32" 4-1/4" 4-7/16" 4-9/16" 4-7/8" 5-1/2" 5-15/16" 6-3/8" 6-3/8" ––
5" 4-1/8" 4-1/4" 4-3/8" 4-5/8" 4-3/4" 5" 5-1/4" 5-9/16" 5-7/8" 6-3/16" 6-3/16"
5" 4-3/8" 4-1/2" 4-5/8" 4-7/8" 5" 5-3/8" 5-5/8" 6" 6-1/4" 6-5/8" 7-1/4"
6" 4-3/4" 4-7/8" 5" 5-1/4" 5-3/8" 5-5/8" 5-7/8" 6-3/16" 6-1/2" 6-13/16" 7-7/16" 8-1/8"
6" 5" 5-1/8" 5-1/4" 5-1/2" 5-5/8" 6" 6-1/4" 6-5/8" 7" 7-1/4" 8" 8-5/8"
LOCKNUT 1-1/4" 1-1/8" 1-11/16" 2-3/16" 2-7/16" 3" 3-7/16" 4-3/16" 4-13/16" 5-3/8" 6-11/16" 7-15/16"
BUSHING 1" 1-1/4" 1-1/2" 1-7/8" 2-1/8" 2-5/8" 3-3/16" 3-7/8" 4-7/16" 5" 6-1/4" 7-3/8"
CONDUIT 7/8" 1-1/16" 1-3/8" 1-11/16" 1-15/16" 2-3/8" 2-7/8" 3-1/2" 4" 4-1/2" 5-9/16" 6-5/8"
1Minimum spacing required to provide clearance over locknuts and bushings.
2Preferred more liberal spacings between centers of conduits to be used whenever possible.
3GU- spacing required for “GU” Series unions.
4Supplied by using a drilled and tapped conduit opening with “GUM” Series union.
5Note: For metric conduit openings round up to the nearest NPT and use “GU” spacing.
Drawing indicates position as looking into open
face of box with short side (top) up.
CONDUIT CONDUIT OPENINGS UNION4
SIZE DRILLED
AND TAPPED
1/2" 1 11
3/4" 2 12
1" 3 13
1-1/4" 4 14
1-1/2" 5 15
2" 6 16
2-1/2" 7 17
3" 8 18
3-1/2" 9 19
4" 0 10
5" 02 –
6" 04 –
(3) Combine the conduit location letter, size
and type number, and add as a suffix
to junction box catalog
number.
Example: EXB-12248 N34-C3-J5-Pl3-AH4
1MIN
2PRE
3GU
1MIN
2PRE
3GU
1MIN
2PRE
3GU
1MIN
2PRE
3GU
1MIN
2PRE
3GU
1MIN
2PRE
3GU
1MIN
2PRE
3GU
1MIN
2PRE
3GU
1MIN
2PRE
3GU
1MIN
2PRE
3GU
1MIN
2PRE
1MIN
2PRE
DEDE
DEi
DISTRIBUTION EQUIPMENT INDEX
Section DE
XEC Series
Circuit Breakers ........................................2
B7C Series
Prism Circuit Breakers ...........................3-6
DEDS Series
Disconnect Switches
3 Pole/Non-Fusible....................................7
XEDS Series
Disconnect Switches
3 Pole/Non-Fusible....................................8
B7NFDSeries
Compact Non-Fused
Disconnect Switches.................................9
EXB-NFD, EXB-FDS Series
Disconnect Switches
3 Pole Non-Fusible & Fusible...........10 - 11
B7L Series
Lighting Panelboards..........12 - 13, 15 - 16
B7P Series
Power Panelboards ..............12, 14, 15 - 16
D2L/D2PC Series
Factory Sealed Panelboards ............17 - 21
EXBLI/EXBPI Series
IEC Circuit Breaker Panelboards......22 - 23
GCBB Series
Circuit Breaker Load Centers ..................24
GFCS Series
Ground Fault Control Station ...................25
SWITCHRACK
ASSEMBLIES .........................................26
08_DEi_DE26.qxd:2010 12/10/10 7:04 PM Page DEi1
XEC SERIES DISTRIBUTION EQUIPMENT
CIRCUIT BREAKER ENCLOSURES
DE2
FEATURES-SPECIFICATIONS
Applications
Hazardous areas due to the pres-
ence of flammable gases or vapors,
combustible dusts, or easily ignitable
fibers or flyings
Installations at petroleum refineries,
chemical and petrochemical plants,
storage areas, and other processing
facilities where hazardous sub-
stances are handled or stored
Provides overcurrent and short circuit
protection of service entrance, feeder
or branch circuits, lighting, heating,
appliance and motor circuits
Features
Rectangular bolted cover design pro-
vides for attractive, compact,
uniform installations
Two cast conduit hubs; one top and
one bottom
Internal circuit breaker handle mech-
anism is a sliding plate type mounted
to the cover
External handle is vault type with
standard provisions for locking in
“OFF” position with up to three
padlocks
Provisions for locking in “ON” posi-
tion available as factory modification
(add suffix SU40 to catalog number)
Circuit breaker is trip free of handle
mechanism
Locking in the “ON” position does not
prevent the circuit breaker from
opening under short circuit or over-
load conditions
Material Specifications
Enclosure and external circuit break-
er handle is cast copper-free alu-
minum alloy (less than 4/10 of 1%)
Cover bolts are stainless steel
SU3 Drain and breather
SU40 Lock “ON”
SUFFIX NUMBER DESCRI PTION
MODIFICATIONS
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 7(C,D) 9(E,F,G)
Listed - File E30962
Certified - File LR18179
See files for details or call Killark.
AMPS AMPS
FRAME VOLTS SYMMETRICAL D.C.
240 VAC 18,000
277 VAC 14,000
480 VAC 14,000
250 VDC 10,000
240 VAC 18,000
480 VAC 14,000
600 VAC 14,000
250 VDC 10,000
EHD
15-100
AMPS
FDB
15-150
AMPS
ELECTRICAL RATINGS INTERRUPTING
CAPACITY
XEC CIRCUIT BREAKERS
XEC DIMENSIONS
CATALOG HUB
NUMBER SIZE ABCDEFGHJ
XECD-4A 1" 8-3/8" 7-7/16" 13/16" 10-1/4" 6" 11-7/8" 1-3/8" 6-7/8" 1-1/2"
(213) (189) (21) (260) (152) (302) (35) (175) (38)
XECE-6A 1-1/4" 8-3/8" 8-3/4" 13/16" 10-1/4" 7-3/8" 11-7/8" 1-3/8" 6-7/8" 2"
(213) (222) (21) (260) (187) (302) (35) (175) (51)
XECF-6A 2" 10-7/8" 9-1/8" 13/16" 13-7/8" 7-3/4" 16" 1-3/4" 7" 2"
(276) (232) (21) (352) (197) (406) (44) (178) (51)
Dimensions
TRIP
AMPS
15
20
30
40
50
60
70
80
90
100
For 40 Amp or less
For 50-100 Amp
CATALOG NUMBER
EHD FRAME FDB FRAME
1-POLE 2-POLE 3-POLE 2-POLE
277 VAC 240/480 VAC 240/480 VAC 600 VAC 3-POLE
125 VDC 250 VDC 250 VDC 600 VAC
XECD-154A1 XECD-154A2 XECE-154A3 XECE-156A2 XECE-156A3
XECD-204A1 XECD-204A2 XECE-204A3 XECE-206A2 XECE-206A3
XECD-304A1 XECD-304A2 XECE-304A3 XECE-306A2 XECE-306A3
XECD-404A1 XECD-404A2 XECE-404A3 XECE-406A2 XECE-406A3
XECF-504A1 XECF-504A2 XECF-504A3 XECF-506A2 XECF-506A3
XECF-604A1 XECF-604A2 XECF-604A3 XECF-606A2 XECF-606A3
XECF-704A1 XECF-704A2 XECF-704A3 XECF-706A2 XECF-706A3
XECF-804A1 XECF-804A2 XECF-804A3 XECF-806A2 XECF-806A3
XECF-904A1 XECF-904A2 XECF-904A3 XECF-906A2 XECF-906A3
XECF-1004A1 XECF-1004A2 XECF-1004A3 XECF-1006A2 XECF-1006A3
XECD-4A XECD-4A XECE-6A XECE-6A XECE-6A
XECF-6A XECF-6A XECF-6A XECF-6A XECF-6A
ENCLOSURE ONLY
NOTE: Space for additional
drill & tap conduit opening
1" for XECD-4A
1-1/4" for XECE-6A
2" for XECF-6A
Also is location for SU3 drain
and breather when requested.
NOTE: A & B dimensions are for mounting.
NOTE: Only Cutler-Hammer Series “C” breakers
fit this series. See B7C series on page
DE3-6 for other brands.
B7C SERIES DISTRIBUTION EQUIPMENT
CIRCUIT BREAKER ENCLOSURES DE3
FEATURES-SPECIFICATIONS
#UL1203-Explosion Proof and
Dust-Ignition-Proof Electrical Equipment
For Use In Hazardous
(Classified) Locations.
File #E83969
#C22.2 NO. 30-M1986-Explosion Proof
Enclosures For Use In Class I Hazardous
Locations.
File #LR11714
Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones 1 & 2, Groups IIB+H2, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4x, 7(B,C,D), 9(E,F,G)
Applications
Locations such as petroleum refiner-
ies, chemical and petroleum plants
with indoor and outdoor processes
Motor control and circuit protection in
locations made hazardous due to the
presence of flammable gases or
vapors, combustible dust, or easily
ignitable fibers and flyings, and areas
which are subject to corrosion,
weather and dampness
To provide overcurrent and short
circuit protection of service entrance,
feeder or branch circuits, lighting,
heating, appliance and motor circuits
To provide line disconnect means
Features
Copper-free, cast aluminum con-
struction (less than 4/10 of 1%)
High strength, lighter in weight,
corrosion resistant
Hinged Cover is standard
More Wiring Room.
Meets the latest NEC/CEC wire
bending requirements for circuit
breaker enclosures
Gasketed Flange.
Nitrile (BUNA-N) “O” ring gasket is
located inside cover bolt circle to pre-
vent water seeping into enclosure
Quick Release, Captivated Cover.
Bolts of 316 Grade Stainless Steel
Triple lead bolts require only 3-1/2
turns to disengage
Material/Finish
Enclosure: Copper-free, cast alu-
minum (less than 4/10 of 1%)
Cover Bolts: 316 grade stainless steel
Mounting Pan: Sheet aluminum
Handle Mechanism: Cast aluminum
with stainless steel shaft and
hardware
Hinges: Aluminum with stainless steel
hardware
Aluminum lacquer paint finish is
standard, with special epoxy finish
available. See page DE6
Ductile Mounting Lugs.
Lugs are made of ductile aluminum
alloy to adjust to irregular mounting
surfaces without damage to enclosure
Universal Mounting Pan.
Sheet aluminum pan is pre-drilled
to facilitate easy field installation of
major circuit breaker brands.
Provisions for grounding supplied
as standard
Conduit Openings Supplied.
Standard conduit openings include
power conduit top and bottom and
a plugged opening suitable for field
installation of drain and breather
Special conduit openings can be
supplied at factory, or can be field
installed
Breaker Handle.
Provisions for lock “ON” or “OFF”
positions with up to three padlocks.
Spring loaded to prevent damage of
breaker toggle and provides positive
handle alignment. “O” ring on shaft to
prevent water seeping into enclosure
Recessed Flange Notches.
Flanges are notched to allow for easi-
er cover opening with prying instru-
ment without flange damage
DE
B7C SERIES DISTRIBUTION EQUIPMENT
CIRCUIT BREAKER ENCLOSURES
DE4
FEATURES-SPECIFICATIONS
B7C CIRCUIT BREAKER ENCLOSURES
ENCLOSURE ONLY
CATALOG NUMBER
B7CA
B7CB
B7CC
B7CD
B7CE
B7CF
MANUFACTURER
CUTLER-HAMMER/WESTINGHOUSE
GENERAL ELECTRIC
ITE - SIEMENS
SQUARE D
CUTLER-HAMMER/WESTINGHOUSE
GENERAL ELECTRIC
ITE - SIEMENS
CUTLER-HAMMER/WESTINGHOUSE
GENERAL ELECTRIC
SQUARE D
CUTLER-HAMMER/WESTINGHOUSE
GENERAL ELECTRIC
ITE - SIEMENS
ITE - SIEMENS
SQUARE D
CUTLER-HAMMER/WESTINGHOUSE
GENERAL ELECTRIC
TE - SIEMENS
SQUARE D
CUTLER-HAMMER/WESTINGHOUSE
GENERAL ELECTRIC
ITE - SIEMENS
ITE - SIEMENS
SQUARE D
F
E150
ED
F
F
E150
ED
J
F225
K
K
J600
FD
JD
L
L
J600
LD
LC
N
K1200
MD
ND
M
EHD, FDB, FD, HFD, FDC
TEB, TED, THED, TEL
ED2, ED4, ED6, HED4, HED6
FAL, FHL, FCL
EHD, FDB, FD, HFD, FDC
TEB, TED, THED, TEL
ED2, ED4, ED6, HED4, HED6
JD, JDB, JDC, HJD
TFJ, TFK, THFK, TFL
KAL, KHL, KCL
DK, KDB, KD, HKD, KDC
TJJ, TJK4, THJK4
FXD6 FD6, HFD6, CFD6
JXD2, JXD6, JD6, HJD6, HHJD6, CJD6
LAL, LHL
LDB, LD, HLD, LDC
TJK6, THJK6
LXD6, LD6, HLD6, HHLD6, CLD6
LCL
ND, HND, NDC
TKM8, THKM8, TKM12, THKM12
MD6, MXD6, HMXD6, HMD6, CMD6
ND6, NXD6, HNXD6, CND6
MAL, MHL
100
100
90
100
150
150
125
250
225
250
400
400
250
400
400
600
600
600
600
1200
1200
800
1200
1000
NOTE: Enclosure includes mounting pan which is pre-drilled to accept circuit breakers illustrated above.
Mounting screw hardware for circuit breaker is not supplied with enclosure and must be furnished by supplier of circuit breaker.
WILL ACCEPT THE FOLLOWING CIRCUIT BREAKERS:
FRAME SIZE CIRCUIT BREAKER TYPE MAX. AMP
B7C ENCLOSURE WITH CIRCUIT BREAKER INSTALLED
B7C SERIES DISTRIBUTION EQUIPMENT
CIRCUIT BREAKER ENCLOSURES DE5
DE
CATALOG NUMBER
MAXIMUM
VOLTAGE
480
600
480
600
480
600
480
600
480
600
480
600
480
600
480
600
480
600
480
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
BREAKER
AMPERAGE
15
15
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
100
100
125
125
150
150
175
200
225
250
250
300
350
400
400
500
600
600
700
800
1000
1200
3 POLE
B7CA-WEHD-43015
B7CA-WFDB-63015
B7CA-WEHD-43020
B7CA-WFDB-63020
B7CA-WEHD-43030
B7CA-WFDB-63030
B7CA-WEHD-43040
B7CA-WFDB-63040
B7CA-WEHD-43050
B7CA-WFDB-63050
B7CA-WEHD-43060
B7CA-WFDB-63060
B7CA-WEHD-43070
B7CA-WFDB-63070
B7CA-WEHD-43080
B7CA-WFDB-63080
B7CA-WEHD-43090
B7CA-WFDB-63090
B7CA-WEHD-43100
B7CA-WFDB-63100
B7CB-WFDB-63125
B7CC-WJDB-63125
B7CB-WFDB-63150
B7CC-WJDB-63150
B7CC-WJDB-63175
B7CC-WJDB-63200
B7CC-WJDB-63225
B7CC-WJDB-63250
B7CD-WKD-63250
B7CD-WKD-63300
B7CD-WKD-63350
B7CD-WKD-63400
B7CE-WLD-63400
B7CE-WLD-63500
B7CE-WLD-63600
B7CF-WND-63600
B7CF-WND-63700
B7CF-WND-63800
B7CF-WND-631000
B7CF-WND-631200
2 POLE
B7CA-WEHD-42015
B7CA-WFDB-62015
B7CA-WEHD-42020
B7CA-WFDB-62020
B7CA-WEHD-42030
B7CA-WFDB-62030
B7CA-WEHD-42040
B7CA-WFDB-62040
B7CA-WEHD-42050
B7CA-WFDB-62050
B7CA-WEHD-42060
B7CA-WFDB-62060
B7CA-WEHD-42070
B7CA-WFDB-62070
B7CA-WEHD-42080
B7CA-WFDB-62080
B7CA-WEHD-42090
B7CA-WFDB-62090
B7CA-WEHD-42100
B7CA-WFDB-62100
B7CB-WFDB-62125
B7CC-WJDB-62125
B7CB-WFDB-62150
B7CC-WJDB-62150
B7CC-WJDB-62175
B7CC-WJDB-62200
B7CC-WJDB-62225
B7CC-WJDB-62250
B7CD-WKD-62250
B7CD-WKD-62300
B7CD-WKD-62350
B7CD-WKD-62400
B7CE-WLD-62400
B7CE-WLD-62500
B7CE-WLD-62600
B7CF-WND-62600
B7CF-WND-62700
B7CF-WND-62800
B7CF-WND-621000
B7CF-WND-621200
FRAME SIZE
EHD
FDB
EHD
FDB
EHD
FDB
EHD
FDB
EHD
FDB
EHD
FDB
EHD
FDB
EHD
FDB
EHD
FDB
EHD
FDB
FDB
JDB
FDB
JDB
JDB
JDB
JDB
JDB
KD
KD
KD
KD
LD
LD
LD
ND
ND
ND
ND
ND
CUTLER-HAMMER/WESTINGHOUSE BREAKERS
CATALOG NUMBER
FRAME SIZE
FAL4
FAL6
FAL4
FAL6
FAL4
FAL6
FAL4
FAL6
FAL4
FAL6
FAL4
FAL6
FAL4
FAL6
FAL4
FAL6
FAL4
FAL6
FAL4
FAL6
KAL
KAL
KAL
KAL
KAL
KAL
LAL
LAL
LAL
LAL
LCL
LCL
MAL
MAL
MAL
MAL
MAL
2 POLE
B7CA-SFAL-42015
B7CA-SFAL-62015
B7CA-SFAL-42020
B7CA-SFAL-62020
B7CA-SFAL-42030
B7CA-SFAL-62030
B7CA-SFAL-42040
B7CA-SFAL-62040
B7CA-SFAL-42050
B7CA-SFAL-62050
B7CA-SFAL-42060
B7CA-SFAL-62060
B7CA-SFAL-42070
B7CA-SFAL-62070
B7CA-SFAL-42080
B7CA-SFAL-62080
B7CA-SFAL-42090
B7CA-SFAL-62090
B7CA-SFAL-42100
B7CA-SFAL-62100
B7CC-SKAL-62125
B7CC-SKAL-62150
B7CC-SKAL-62175
B7CC-SKAL-62200
B7CC-SKAL-62225
B7CC-SKAL-62250
B7CD-SLAL-62250
B7CD-SLAL-62300
B7CD-SLAL-62350
B7CD-SLAL-62400
B7CE-SLCL-62500
B7CE-SLCL-62600
B7CF-SMAL-62600
B7CF-SMAL-62700
B7CF-SMAL-62800
B7CF-SMAL-621000
3 POLE
B7CA-SFAL-43015
B7CA-SFAL-63015
B7CA-SFAL-43020
B7CA-SFAL-63020
B7CA-SFAL-43030
B7CA-SFAL-63030
B7CA-SFAL-43040
B7CA-SFAL-63040
B7CA-SFAL-43050
B7CA-SFAL-63050
B7CA-SFAL-43060
B7CA-SFAL-63060
B7CA-SFAL-43070
B7CA-SFAL-63070
B7CA-SFAL-43080
B7CA-SFAL-63080
B7CA-SFAL-43090
B7CA-SFAL-63090
B7CA-SFAL-43100
B7CA-SFAL-63100
B7CC-SKAL-63125
B7CC-SKAL-63150
B7CC-SKAL-63175
B7CC-SKAL-63200
B7CC-SKAL-63225
B7CC-SKAL-63250
B7CD-SLAL-63250
B7CD-SLAL-63300
B7CD-SLAL-63350
B7CD-SLAL-63400
B7CE-SLCL-63500
B7CE-SLCL-63600
B7CF-SMAL-63600
B7CF-SMAL-63700
B7CF-SMAL-63800
B7CF-SMAL-631000
SQUARE D BREAKERS
NOTE: See page DE6 for dimensional information and circuit breaker interrupting information.
TECHNICAL DATA INTERRUPTING CAPACITY RATINGS (SYMMETRICAL AMPERES)
240
18,000
18,000
65,000
65,000
65,000
65,000
25,000
25,000
42,000
42,000
100,000
42,000
VOLTS AC VOLTS DC
BREAKER FRAME
480
14,000
14,000
25,000
35,000
35,000
50,000
18,000
18,000
25,000
30,000
65,000
30,000
600
14,000
18,000
25,000
25,000
25,000
14,000
22,000
22,000
35,000
22,000
250
10,000
10,000
10,000
10,000
22,000
10,000
10,000
10,000
10,000
14,000
Consult factory for requirements on higher interrupting rated breakers.
*To be ordered as separate item with notation on order for assembly into enclosure.
CUTLER-HAMMER/
WESTINGHOUSE
EHD
FDB
JDB
KD
LD
ND
SQUARE D
FA L 4
FA L 6
KAL
LAL
LCL
MAL
Dimensions
Dimensions
Figure 3
Figure 2
ACCESSORIES / OPTIONS*
CATALOG NUMBER
SU31
SU3B1 2
B7CGRND
B7C-SN1
B7C-SN2
B7C-SN3
B7C-SN4
B7SF
B7SPNPT
DESCRIPTION
Drain & breather NEMA 3, 7CD, 9EFG
Drain & breather NEMA 3, 7BCD, 9EFG
Grounding lug kit
Solid neutral 150 AMP
Solid neutral 250 AMP
Solid neutral 600 AMP
Solid neutral 1200 AMP
Special epoxy finish
Change standard conduit openings
NOTE: Modifications to Internal Circuit Breaker such as Shunt Trip,
Auxiliary Switches, Alarm Switch and Undervoltage Release Mechanism
are available and should be ordered by description.
1Installation of Drain & Breather will void the NEMA 4-4x rating.
2Not CSA
B7C DIMENSIONS
DIMENSIONS (CONTINUED)
CATALOG
NUMBER
B7CA
B7CB
B7CC
B7CD
B7CE
B7CF
USE
FIGURES
1,2
1,2
1,2
1,2
1,3
1,3
CATALOG
NUMBER
B7CA
B7CB
B7CC
B7CD
B7CE
B7CF
USE
FIGURES
1, 2
1, 2
1, 2
1, 2
1, 3
1, 3
DIMENSIONS
A
18"
26-1/4"
34-1/4"
34-1/4"
45-3/8"
62-1/4"
B
11"
12-1/2"
16-1/2"
16-1/2"
17-1/2"
20-1/4"
C
9-1/8"
10-3/4"
11-1/2"
11-1/2"
9-5/8"
15"
D
3-5/8"
5"
9"
9"
N/A
N/A
D*
N/A
N/A
N/A
N/A
15-1/4"
18-1/2"
E
16-3/8"
24-5/8"
32-5/8"
32-5/8"
N/A
N/A
E*
N/A
N/A
N/A
N/A
33"
43-1/2"
F
1-3/4"
1-3/4"
1-3/4"
2-5/8"
2-5/8"
2-5/8"
G
2-15/16"
4-5/16"
4-11/16"
4-11/16"
3-3/16"
5-3/8"
H
3-11/16"
5-3/4"
6-1/4"
6-1/4"
4-1/2"
7-3/8"
I
2-3/8"
2-3/4"
4"
4"
2-3/4"
3-1/2"
J
2-1/8"
2-1/2"
3-3/4"
3-3/4"
2-3/4"
3-1/2"
K
1-1/2"
2"
3"
3"
3"
4"
L
3/4"
1"
1"
1"
1/2"
1/2"
M
1/2"
1/2"
1/2"
1/2"
N/A
N/A
46
80
155
155
215
540
CONDUIT OPENINGS TOP & BTM. (NPT) EST. ENCL.
WT. (LBS.)
Figure 1
B7C SERIES DISTRIBUTION EQUIPMENT
CIRCUIT BREAKER ENCLOSURES
DE6
DEDS SERIES DISTRIBUTION EQUIPMENT
DISCONNECT SWITCHES 3 POLE/NON-FUSIBLE DE7
FEATURES-SPECIFICATIONS
DE
Applications
Hazardous areas due to the pres-
ence of combustible dusts or easily
ignitable fibers or flyings
Use in damp or wet locations. Either
indoor or outdoor installations
Installations such as feedmills, grain
elevators, coal handling facilities,
certain chemical, fertilizer and food
processing industries where either
hazardous or non-hazardous dusts
are handled or stored
Use in accordance with the
NEC/CEC where a horsepower rated
quick make-quick break disconnect
means for a motor and its controller
is permitted
Features
(30-60-100 Amp Housing Styles)
Bolted and gasketed cabinet type
construction insures the exclusion
of conductive or combustible dusts
from entering the assembly.
Enclosure and external handle is
copper-free aluminum alloy (less
than 4/10 of 1%)
Cover bolts are stainless steel
External handle is vault type with
standard provisions for locking in
the “OFF” position with up to three
padlocks
Provisions for locking in “ON” posi-
tion available as factory modification.
(Add suffix SU40 to catalog number)
Cutler-Hammer Type-DS Switches
Two cast conduit hubs; one top and
one bottom
Listed - File E53290
Certified - File LR11714
See files for details or call Killark.
CATALOG NUMBER
ENCLOSURE ENCLOSURE WITH ENCLOSURE WITH ENCLOSURE ONLY
WITH SWITCH AND SWITCH AND TWO (WITHOUT SWITCH OR
SWITCH
SWITCH AUXILIARY CONTACTS AUXILIARY CONTACTS AUXILIARY CONTACTS)
RATING
DEDS-30 DEDS-30A DEDS-30AA DEDS-A 30 AMP
DEDS-60 DEDS-60A DEDS-60AA DEDS-A 60 AMP
DEDS-100 DEDS-100A DEDS-100AA DEDS-B 100 AMP
DEDS DISCONNECT SWITCHES
DEDS ELECTRICAL RATINGS
SWITCH
AMPERES 120 VAC 240 VAC 480 VAC 600 VAC 250 VDC
30 5 10 20 25 7-1¼2
60 10 20 4 0 60 15
100 15 30 75 75 25
MAXIMUM HORSEPOWER–THREE PHASE–3-POLE
Auxiliary Switch Kits are available for separate control circuit applications. Each auxiliary switch has
one normally open and one normally closed contact. Each switch includes three soldered, identified
leads.
Rated 15 amps at 250 volts maximum.
1SU3 voids NEMA 4 ratings
DEDS DIMENSIONS
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3R, 4, 9(E,F,G)
Internal disconnect handle mecha-
nism is a sliding plate mounted to
the cover
SUFFIX NUMBER DESCRIPTION
MODIFICATIONS
SU31Drain and breather
SU17 100 Amp solid neutral
SU40 Lock “on” for handle
KIT-251 100 Amp ground lug
Dimensions
Note: Space for additional drill & top conduit opening. 1-1/4” for DEDS-A.
2” for DEDS-B. Also is location for SU3 drain and breather when required.
ENCLOSURE
CATALOG CONDUIT
NUMBER SIZE ABCDEFGHJ
DEDS-A 1-1/4" 8-3/8" 8-13/16" 7/16" 10-1/4" 7-3/8" 12-1/8" 1-3/8" 6-7/8" 2"
(213) (224) (11) (260) (187) (308) (35) (175) (51)
DEDS-B 2" 10-7/8" 9-1/8" 7/16" 13-7/8" 7-3/4" 15-3/8" 1-3/4" 6-7/8" 2"
(276) (232) (11) (252) (197) (391) (44) (175) (51)
XEDS SERIES DISTRIBUTION EQUIPMENT
DISCONNECT SWITCHES 3 POLE/NON-FUSIBLE
XEDS-30
Listed - File E53290
Certified - File LR1171
See files for details or call Killark.
Applications
Hazardous areas due to the presence
of flammable gases or vapors, com-
bustible dusts or easily ignitable fibers
or flyings
Use in accordance with the NEC/CEC
where a horsepower rated quic make-
quick break disconnect means for a
motor and its controller is permitted
30-60-100 Amp Housing
External handle is vault type with stan-
dard provisions for locking in “OFF”
position with up to three padlocks
Provisions for locking in “ON” position
available as factory modification
(add suffix SU40 to catalog number)
Enclosure and external handle is
cast copper-free aluminum alloy (less
than 4/10 of 1%)
Cover bolts are stainless steel
Cutler-Hammer Type-DS Switches
30-60-100 Amp Housing
Two cast conduit hubs; one top and
one bottom
Internal disconnect handle mechanism
is a sliding plate mounted to the cover
XEDS ELECTRICAL RATINGS
MAXIMUM HORSEPOWER–THREE PHASE–3-POLE
120 VAC
5
10
15
240 VAC
10
20
30
480 VAC
20
40
75
600 VAC
25
60
75
250 VDC
7-1¼2
15
25
SUFFIX NUMBER DESCRIPTION
MODIFICATIONS
ABCDEFGHJ
8-3/8" 8-3/4" 7/16" 10-1/4" 7-3/8" 11-7/8" 1-3/8" 6-7/8" 2"
(213) (222) (11) (260) (187) (302) (35) (175) (51)
10-7/8" 9-1/8" 7/16" 13-7/8" 7-3/4" 16" 1-3/4" 7" 2"
(276) (232) (11) (352) (197) (406) (44) (178) (51)
CATALOG
NUMBER
XEDS-A
XEDS-B
XEDS DIMENSIONS
HUB
SIZE
1-1/4"
2"
Dimensions
CATALOG NUMBER
ENCLOSURE ENCLOSURE WITH ENCLOSURE WITH ENCLOSURE ONLY SWITCH
WITH SWITCH AND SWITCH AND TWO (WITHOUT SWITCH OR RATING
SWITCH AUXILIARY CONTACTS AUXILIARY CONTACTS AUXILIARY CONTACTS)
XEDS DISCONNECT SWITCHES
XEDS-30
XEDS-60
XEDS-1001
XEDS-30A
XEDS-60A
XEDS-100A1
XEDS-30AA
XEDS-60AA
XEDS-100AA1
XEDS-A
XEDS-B
XEDS-B1
30
60
100
Auxiliary switch kits are available for separate con-
trol circuit applications. Each auxiliary switch has
one normally open and one normally closed con-
tact. Each switch includes three soldered, identi-
fied leads. Rated 15 amps at 250 volts maximum.
1Due to wire gutter space, this unit must be
wired with incoming (line) connection through
the top hub and outgoing (load) connection to
the bottom hub.
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 7(C,D) 9(E,F,G)
XEDS
NOTE: Space for additional
drill & tap conduit opening
1-1/4" for XEDS-30
2" for XEDS-60+100
Also is location for SU3 drain
and breather when requested.
SU3 Drain and breather
SU17 100 Amp solid neutral
SU18 225 Amp solid neutral
SU40 Lock “on” for handle
KIT-251 100 Amp ground lug
NOTE: A & B dimensions are for mounting.
SWITCH
AMPERES
30
60
100
FEATURES-SPECIFICATIONS
DE8
Enclosure OUTSIDE BOX NOMINAL MOUNTING
DIMENSIONS INSIDE BOX DIMENSIONS
ABCD EFGH I JK
B7NFD1 5-3/4 8-1/16 6-5/16 3-5/8 5-13/16 5-1/16 3-1/8 8-1/8 --1-1/4
B7NFD2 8-1/8 13-1/16 7-13/16 4-1/4 9-3/16 6-5/16 2-1/2 11-3/8 6-3/8 7-1/2 1-13/16
B7NFD SERIES DISTRIBUTION EQUIPMENT
COMPACT NON-FUSED DISCONNECT SWITCHES
FEATURES-SPECIFICATIONS
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+ H2, llA
Class II, Div. 1 & 2, Groups E,F,G1
Class III
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
B7NFD1 B7NFD2
Certified - File LR11714
Fixed Lug Position For B7NFD1
Optional Position For B7NFD2
Standard Lug Position For B7NFD2
B7NFD1 B7NFD2
Applications
The PRISM®B7 Series of non-fused dis-
connect switches are used:
In locations made hazardous due to the
presence of flammable gasses or vapors
or ignitable dusts, fibers and flyings.
Outdoors or indoors in damp, wet and
dirty locations, or in areas where frequent
washdowns, heavy rain or water spray
routinely occurs.
Use as motor circuit disconnect.
PRISM®enclosures universal design
accomodates the following manufacturers
switches as standard:
Advance Controls 14046 Series
Allen-Bradley 194E Series (B7NFD1 only)
ABB OT Series
Cutler-Hammer C362N Series
Sprecher + Schuh LA7 Series
Ferraz Shawmut LBS Series
Advance Controls © Advance Controls Inc.
Allen-Bradley © Rockwell Automation
ABB © Tne ABB Group
Cutler-Hammer © Eaton Corporation
Sprecher + Schuh © Sprecher + Schuh
Features
Compact size enclosures provide
application flexibility with cost savings
over industry standard sizes
Fewer cover bolts reduces installation
and maintenance time
Gasketed flange with O-ring located in
side bolt circle to seal out moisture
Rotary handle style operating mecha-
nism with lockout provision as standard
Removable ductile mounting lugs
adjust to irregular mounting surfaces
Bodies have top and bottom drilled and
tapped conduit entrances for power con-
nection, with custom openings available
ABB UL98 certified switch supplied for
30-100 Amp units
Standard Materials /Finish
Enclosures: Copper-free aluminum
(less than 4/10 of 1% copper content)
Cover Bolts: 316 Stainless Steel
O-ring Gasket: Silicone
Finish: Grey Powder Polyester painted
exterior, electrostatically applied.
Electrical rating: 600VAC, 30 - 100 Amp
KIT-251 100 amp ground lug
SU-2 Hinge-9 Installed
SU3* Drain & Breather installed (NEMA 7CD)
SU3B* Drain & Breather installed (NEMA 7BCD)
SU9 Special paint finish
A1 NC+1NO Auxiliary
B7SPNPT Change std. conduit size and location
SU14 Fungus proofing of enclosures
SUFFIX DESCRIPTION
NUMBER
*NOTE: The installation of a Drain & Breather
will void the NEMA 4-4X ratings of enclosure.
MODIFICATIONS
** Use MN. 75oC wire
CATALOG NUMBER SWITCH SINGLE PHASE HP THREE PHASE HP DC HP WIRE CONDUIT
ENCLOSURE ONLY W/ABB AMPS / PHASE 120VAC 230VAC 208VAC 230VAC 480VAC 600VAC 230VDC SIZE** SIZES
B7NFD1 B7NFD13A 30 / 3P 2510 10 20 30 1 #14-10 1 NPT
B7NFD2 B7NFD26A 60 / 3P 3 7.5 20 20 40 40 10 #14-4 1-1/2 NPT
B7NFD2 B7NFD21A 100 / 3P 5 15 25 30 50 50 20 #8-1 1-1/2 NPT
DIMENSIONS
ADAPTER KIT
Required for Allen-Bradley and
Sprecher + Schuh disconnects
Order separately
B7KIT - NRW
DE
DE9
EXB-NFD, EXB-FDS SERIES DISTRIBUTION EQUIPMENT
DISCONNECT SWITCHES 3 POLE/NON-FUSIBLE & FUSIBLE
FEATURES-SPECIFICATIONS
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+ H2, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
#UL698& #UL1203 - Explosion Proof and
Dust Ignition Proof Electrical Equipment.
Files #E83969 & E12379
#C22.2 No. 30-M1986 - Explosion Proof
Enclosure for use in Class I Hazardous
Locations. File #LR11716
Applications
EXP-NFD and EXB-FDS Series hinged
cover disconnect switches are used:
In locations made hazardous due to
the presence of flammable gasses
or vapors or ignitable dusts, fibers
and flyings.
Outdoors or indoors in damp, wet
and dirty locations, or in areas where
frequent washdowns, heavy rain or
water spray routinely occurs.
Use as motor circuit disconnect and
to provide short circuit protection
(fused version) of lighting and power
circuits.
Features
Copper-free aluminum construction,
high strength, lighter in weight and
corrosion resistant.
Fewer cover bolts (no corner bolts
required) reduces installation and
maintenance time. Cover bolts are
stainless steel.
Gasketed flange with O-ring located
in side bolt circle to seal
out moisture.
Stainless steel hinges are standard.
Switch operating handle of copper-
free aluminum can be padlocked,
with up to 3 locks, in either the
“ON” or “OFF” position.
Ductile mounting lugs adjust to
irregular mounting surfaces.
Bodies have top and bottom drilled
and tapped conduit entrances for
power and drain/breather.
Switches are used on all 30 to
400 Ampere assemblies.
For Horsepower Ratings and
Dimensions, see page DE11.
Disconnect Switches suitable for type
‘J’ fuses only.
Standard Materials/Finish
Enclosures: Copper-free aluminum
(less than 4/10 of 1% copper content
Hinges and Cover Bolts: Stainless
steel
Aluminum lacquer paint finish
Electrical Rating Ranges
600 VAC
30, 60, 100, 200 and 400 Amp
Consult Factory for special conduit
layouts and ATEX requirements
ABB
EXB-NFD NON FUSED DISCONNECT SWITCHES
CATALOG NUMBER SWITCH RATING TYPE CONDUITS top/bot. WIRE SIZE
EXB-NFD-0303P 30 3 Pole (1) 2” (1) 1/2” #14-4
EXB-NFD-0306P 30 6 Pole (2) 2” (1) 1/2” #14-4
EXB-NFD-0303PDT 30 3P Double Throw (2) 2” (1) 1/2” #14-4
EXB-NFD-0603P 60 3 Pole (1) 2” (1) 1/2” #14-4
EXB-NFD-0606P 60 6 Pole (2) 2” (1) 1/2” #14-4
EXB-NFD-0603PDT 60 3P Double Throw (2) 2” (1) 1/2” #14-4
EXB-NFD-1003P 100 3 Pole (1) 2” (1) 1/2” #8- 1/0
EXB-NFD-1006P 100 6 Pole (2) 2” (1) 1/2” #8-1/0
EXB-NFD-1003PDT 100 3P Double Throw (2) 2” (1) 1/2” #8-1/0
EXB-NFD-2003P 200 3 Pole (1) 3” (1) 1/2” #4-300MCM
EXB-NFD-4003P 400 3 Pole (2) 3” (1) 1/2” #2-600MCM
EXB-FDS FUSED DISCONNECT SWITCHES (Type J Fuses)
CATALOG NUMBER SWITCH RATING TYPE CONDUITS top/bot. WIRE SIZE
EXB-FDS-0303P 30 3 Pole (1) 2” (1) 1/2” #14-4
EXB-FDS-0603P 60 3 Pole (1) 2” (1) 1/2” #14-4
EXB-FDS-1003P 100 3 Pole (1) 2” (1) 1/2” #14-2/0
EXB-FDS-2003P 200 3 Pole (1) 3” (1) 1/2” #4-300MCM
EXB-FDS-4003P 400 3 Pole (2) 3” (1) 1/2” #2-600MCM
MODIFICATIONS
SUFFIX NUMBER DESCRIPTION
KIT-251 100 amp ground lug
KIT-252 225 amp ground lug
SU3* Drain/Breather install NEMA 7CD
SU3B* Drain/Breather install NEMA 7BCD
SU9 Special Paint Finish
4P 4th pole 30, 60, 100A - 3 pole only*
A1 NC+1NO Auxiliary
AA 2 NC+2NO Auxiliary
NOTE: The installation of a Drain & Breather will void the NEMA
4-4X ratings of enclosure.
*non-fused
DE10
SWITCH MAXIMUM HORSEPOWER - THREE PHASE-3 POLE
AMPERES 200-208 VAC 240 VAC 480 VAC 600 VAC 230 VAC
30 10 10 20 30 1
60 20 20 40 40 10
100 25 30 50 50 20
200 60 75 150 200 75
400 100 125 250 350 150
AMP BASIC CONDUIT SIZE
RATING ENCLOSURE AB C DEFGH
30/60 EXB-886 N34 SU1 12-5/16 12-5/16 6 9-7/8 3-13/16 8-1/8 9-7/16 2”
100 EXB-8106 N34 SU1 14-5/16 12-5/16 8 9-7/8 3-7/8 8-5/16 9-5/8 2”
200 EXB-12248 N34 SU1 28-3/8 16-3/8 18-7/8 14-15/16 5-3/8 11-5/16 12-5/8 3”
400 EXB-12368 N34 SU1 41-1/4 17-1/4 31 15 5-3/16 11-3/8 12-11/16 (2) 3”
EXB-NFD, EXB-FDS SERIES DISTRIBUTION EQUIPMENT
DISCONNECT SWITCHES 3 POLE/NON-FUSIBLE & FUSIBLE
FEATURES-SPECIFICATIONS
AMP BASIC CONDUIT SIZE
RATING ENCLOSURE AB C DEFGH
30 EXB-8106 N34 SU1 14-5/16 12-5/16 8 9-7/8 3-7/8 8-15/16 9-5/8 2”
60 EXB-10108 N34 SU1 15-1/4 15-1/4 14-15/16 12-15/16 5-1/16 10-15/16 12-1/4 2”
100 EXB-12188 N34 SU1 22-3/8 16-3/8 12-7/8 14-15/16 5-3/8 11-1/16 12-3/8 2”
200 EXB-12248 N34 SU1 28-3/8 16-3/8 18-7/8 14-15/16 5-3/8 11-15/16 13-3/8 3”
400 EXB-183610 N34 SU1 40-3/8 22-3/8 31-1/2 21-1/4 14-3/8 14-3/8 16-1/2 (2) 3”
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+ H2, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
#UL698& #UL1203 - Explosion Proof and Dust
Ignition Proof Electrical Equipment.
Files #E83969 & E12379
#C22.2 No. 30-M1986 - Explosion Proof Enclosure
for use in Class I Hazardous Locations. File
#LR11716
EXB-NFD ELECTRICAL RATINGS
EXB-FDS ELECTRICAL RATINGS
SWITCH MAXIMUM HORSEPOWER - THREE PHASE-3 POLE
AMPERES 200-208 VAC 240 VAC 480 VAC 600 VAC 230 VDC
30 5.75 7.5 15 20 7.5
60 15 15 30 50 20
100 25 30 50 60 50
200 50 60 125 150 60
400 100/125 125 250 350 150
EXB-NFD DIMENSIONS
EXB-FDS DIMENSIONS
H, (1) TOP & (1) BOTTOM.
ON 400 AMP (2) TOP
& (2) BOTTOM.
1/2-14 NPT, (1)TOP
& (1) BOTTOM FOR
DRAIN BREATHER.
DE
DE11
B7L/B7P SERIES DISTRIBUTION EQUIPMENT
CIRCUIT BREAKER PANELBOARDS
FEATURES-SPECIFICATIONS
Applications
Hazardous locations due to the pres-
ence of flammable gases or vapors,
combustible dust or easily ignitable
fibers and flyings, and areas subject
to corrosion, weather and dampness
Petroleum refineries, chemical and
petrochemical plants with indoor and
outdoor processes
Applications requiring overcurrent
and short circuit protection of light-
ing, appliances, heating and motor
circuits
Features
NEMA 4, 4x rated for protection from
hose directed water and corrosion
Standard electrical components:
B7L-Cutler-Hammer Quicklag
Breakers B7P-Cutler-Hammer Series
C Breakers
B7L and B7P furnished with copper
buss
Main lugs. Mechanical solderless
type, approved for CU or AL
conductors
Solid Neutral standard. Single phase
3 wire. Three phase 4 wire
Copper ground bar standard
Main and branch breaker handles
can be padlocked in “ON” or “OFF”
position
Top feed panel standard with bottom
feed optional
Hinged cover, installed as standard
Quick release, captivated coverbolts
of 316 stainless steel
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+H2, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4x, 7(B,C,D) 9(E,F,G)
Classified — File E83969
See files for details or call Killark.
Standard Materials
Enclosure: Copper-free aluminum
(less than 4/10 of 1%)
Main Breaker Handle: Copper-free
aluminum
Cover bolts: 316 grade stainless steel
Flange Gasket “O” Ring: Buna-N
Nitrile
Branch Breaker Operators: Valox
Thermoplastic Polyester handle
molded onto 316 stainless steel shaft
with neoprene “O” ring
Hinges: Copper-free aluminum with
stainless steel pin and hardware
Mounting Lugs: 1/4" thick aluminum
Panel Selection Factors
Basic information required when speci-
fying panelboards is as follows:
Environment
Service (Voltage/Frequency/Phase)
Interrupting capacity
AMP Rating of Main (Lugs only or
Breaker)
Branch Breaker (Type/Number of
Poles/Amperage)
Ordering Information
Specifying and ordering a complete
panelboard assembly requires the
selection of three components.
(1) Basic Panel (2) Branch Breaker and
(3) Options (if required). This method of
cataloging permits a wide variety and
maximizes circuit flexibility in our pan-
elboard offering. Components supplied
in each of these selections include:
1) Basic Panelboard Enclosures
(page DE12)
Explosion-proof enclosure consisting
of box and cover
Cover predrilled and plugged for
maximum number of branch breaker
handles (handles not supplied)
Box supplied with conduit openings
Main circuit breaker and external
handle (when specified)
Panelboard internal chassis with buss
bars but less branch circuit breakers
2) Branch Circuit Breakers (page DE15)
Internal circuit breaker
External handle mechanism with
internal tripping mechanism
Test pushbutton for GFI (when
ordered)
Lockout shield with on-off-trip-reset
identification
3) Options - Accessories (page DE15)
Ordering Example
Specification is for a 3 phase 120/208
volt panel with 100 Amp main lugs
complete with (4) single pole 20 Amp
(2) double pole 20 Amp and (1) three
pole 30 Amp branch breakers.
Branch Breaker Total =
(4) 1 Pole = 4 Poles Total
(2) 2 Pole = 4 Poles Total
(1) 3 Pole = 3 Poles Total
Total 11 Branch Poles
Specification/Ordering Example
B7L20 - 312 - ML100 (Basic panel-
board enclosure) with:
(4) B7BLA1020 (1 Pole 20 Amp Branch)
(2) B7BLA2020 (2 Pole 20 Amp Branch)
(1) B7BLB3030 (3 Pole 30 Amp Branch)
Catalog Logic
See page DE16 for panelboard catalog
number logic for basic enclosures.
c
Certified-File LR 11713 for B7L
DE12
TYPE NO. OF VOLT AMPERES
POLES SYMMETRICAL
BAB11 120 10,000 AIC
BAB12 120/240 10,000 AIC
BAB13 240 10,000 AIC
BABSWN11 120/240 10,000 AIC
BABSWN12 120/240 10,000 AIC
QBGF 1 120 10,000 AIC
QBGF 2 120/240 10,000 AIC
QBGFEP 1 120 10,000 AIC
QBGFEP 2 120/240 10,000 AIC
BAB*D21 120 10,000 AIC
BAB*D22 120/240 10,000 AIC
B7L SERIES DISTRIBUTION EQUIPMENT
LIGHTING PANELBOARDS
Classified — File E83969
See files for details or call Killark.
CIRCUIT BREAKER RATINGS
1Type BAB also rated for 80V DC at 5,000 AIC.
2Type BAB* D designed for HID lighting
applications.
NOTE: Main breaker panel includes main breaker and its price in basic enclosure part number. Refer to page DE15 for branch breaker ordering information.
ELECTRICAL
RATING
Single phase
3 wire
with solid neutral
120/240 VAC
Three phase
4 wire
with solid neutral
120/208 VAC
12
18
18
24
24
30
30
36
42
12
18
18
24
24
30
30
36
42
B7L PANEL WITHOUT MAIN BREAKER (MAIN LUGS ONLY) LESS BRANCH BREAKERS
100
100
225
100
225
100
225
225
225
100
100
225
100
225
100
225
225
225
MAIN LUG
RATING
NUMBER OF
BRANCH POLES
CATALOG NUMBER
BASIC ENCLOSURE AND CHASSIS
ENCLOSURE
BOX SIZE
MAIN WIRE
RANGE
B7L20 - 112 - ML100
B7L29 - 118 - ML100
B7L29 - 118 - ML225
B7L29 - 124 - ML100
B7L41 - 124 - ML225
B7L41 - 130 - ML100
B7L41 - 130 - ML225
B7L41 - 136 - ML225
B7L41 - 142 - ML225
B7L20 - 312 - ML100
B7L29 - 318 - ML100
B7L29 - 318 - ML225
B7L29 - 324 - ML100
B7L41 - 324 - ML225
B7L41 - 330 - ML100
B7L41 - 330 - ML225
B7L41 - 336 - ML225
B7L41 - 342 - ML225
A
B
B
B
C
C
C
C
C
A
B
B
B
C
C
C
C
C
E
G
F
G
F
G
F
F
F
E
G
F
G
F
G
F
F
F
B7L PANEL WITH BACK FEED MAIN BREAKER LESS BRANCH BREAKERS
Three phase
4 wire
with solid neutral
120/208 VAC
ELECTRICAL
RATING
MAIN BREAKER
FRAME
MAIN BREAKER
AND RATING
NUMBER OF
BRANCH POLES
CATALOG NUMBER
BASIC ENCLOSURE AND CHASSIS
ENCLOSURE
BOX SIZE
MAIN WIRE
RANGE
J
J
J
J
J
J
J
J
B
B
C
C
B
B
C
C
B7L29 - 112 - MBB100
B7L29 - 118 - MBB100
B7L41 - 124 - MBB100
B7L41 - 130 - MBB100
B7L29 - 312 - MBB100
B7L29 - 318 - MBB100
B7L41 - 324 - MBB100
B7L41 - 330 - MBB100
12
18
24
30
12
18
24
30
100
100
100
100
100
100
100
100
BAB
BAB
BAB
BAB
BAB
BAB
BAB
BAB
B7L PANEL WITH MAIN BREAKER LESS BRANCH BREAKERS
CATALOG NUMBER
BASIC ENCLOSURE AND CHASSIS
B7L29 - 112 - MBE100
B7L41 - 118 - MBE100
B7L41 - 124 - MBE100
B7L41 - 124 - MBC225
B7L41 - 130 - MBE100
B7L41 - 130 - MBC225
B7L50 - 136 - MBC225
B7L50 - 142 - MBC225
B7L29 - 312 - MBE100
B7L41 - 318 - MBE100
B7L41 - 324 - MBE100
B7L41 - 324 - MBC225
B7L41 - 330 - MBE100
B7L41 - 330 - MBC225
B7L50 - 336 - MBC225
B7L50 - 342 - MBC225
ENCLOSURE
BOX SIZE
MAIN WIRE
RANGE
NUMBER OF
BRANCH POLES
MAIN BREAKER
AND RATING
MAIN BREAKER
FRAME
ELECTRICAL
RATING
Single phase
3 wire
with solid neutral
120/240 VAC
Three phase
4 wire
with solid neutral
120/208 VAC
EHD
EHD
EHD
ED
EHD
ED
ED
ED
EHD
EHD
EHD
ED
EHD
ED
ED
ED
12
18
24
24
30
30
36
42
12
18
24
24
30
30
36
42
B
C
C
C
C
C
D
D
B
C
C
C
C
C
D
D
H
H
H
I
H
I
I
I
H
H
H
I
H
I
I
I
100
100
100
225
100
225
225
225
100
100
100
225
100
225
225
225
Cutler-Hammer type BA circuit
breaker 1 - 2 or 3 pole.
Catalog numbers on this page are for
the basic panelboard enclosure only
with a panel interior chassis containing
main lugs or main breaker as illustrated.
Internal branch breakers and external
handles are NOT included in the basic
enclosure catalog number and must be
ordered as separate items.
Branch circuit loads
The interior panel chassis supplied in
B7L panel is limited to a maximum of
140 amperes at any one connection
point. Breakers of 50 thru 100 amps
must be installed opposite breakers of
smaller amperage so as not to exceed
the 140 ampere limitation.
c
Single phase
3 wire
with solid neutral
120/240 VAC
Certified-File LR 11713
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+H2, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4x, 7(B,C,D) 9(E,F,G)
DE
DE13
B7P SERIES DISTRIBUTION EQUIPMENT
POWER PANELBOARDS
FEATURES-SPECIFICATIONS
Cutler-Hammer Series “C” Circuit
Breakers 1-2 or 3 pole.
Catalog numbers on this page are for the
basic panelboard enclosure only with a
panel interior chassis containing main
lugs or main breaker as illustrated.
Internal branch breakers and external han-
dles are NOT included in the basic enclo-
sure catalog number and must be ordered
as separate items.
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+H2, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4x, 7(B,C,D) 9(E,F,G)
Classified — File E83969
See files for details or call Killark.
B7P CIRCUIT BREAKER RATINGS
1
2&3
2&3
EHD
EHD
FDB
AC
277
480
600
DC
125
250
250
240AC
18000
18000
277AC
14000
480AC
14000
14000
600AC
14000
125DC
10000
250DC
10000
10000
AMPERES SYMMETRICALMAXIMUM VOLTS
TYPE NUMBER OF POLES
B7P PANEL WITH MAIN BREAKER LESS BRANCH BREAKERS
MAIN BREAKER
MAX. VOLTS AMPS FRAME
480
600
600
480
600
600
480
600
100
100
225
100
100
225
100
100
EHD
FDB
JDB
EHD
FDB
JDB
EHD
FDB
ELECTRICAL
RATING
NUMBER OF
BRANCH POLES
3 Phase
4 Wire
with Solid Neutral
Up to 600 VAC
6
6
12
15
15
18
21
21
CATALOG NUMBER
ENCLOSURE AND CHASSIS
B7P29 - 306 - MBE100
B7P29 - 306 - MBF100
B7P41 - 312 - MBJ225
B7P41 - 315 - MBE100
B7P41 - 315 - MBF100
B7P50 - 318 - MBJ225
B7P50 - 321 - MBE100
B7P50 - 321 - MBF100
ENCLOSURE
BOX SIZE
MAIN WIRE
RANGE
K
K
L
K
K
L
N
N
B
B
C
C
C
D
D
D
PANEL WITH BACK FEED MAIN BREAKER LESS BRANCH BREAKERS
MAIN BREAKER
MAX. VOLTS AMPS FRAME
ELECTRICAL
RATING
NUMBER OF
BRANCH POLES
CATALOG NUMBER
ENCLOSURE AND CHASSIS
ENCLOSURE
BOX SIZE
MAIN WIRE
RANGE
9
9
18
18
24
24
3 Phase
4 Wire
with solid neutral
up to 600 VAC
480
600
480
600
480
600
100
100
100
100
100
100
EHD
FDB
EHD
FDB
EHD
FDB
B7P29 - 309 - MBE100
B7P29 - 309 - MBF100
B7P41 - 318 - MBE100
B7P41 - 318 - MBF100
B7P50 - 324 - MBE100
B7P50 - 324 - MBF100
K
K
K
K
K
K
B
B
C
C
D
D
B7P PANEL WITHOUT MAIN BREAKER (MAIN LUGS ONLY) LESS BRANCH BREAKERS
CATALOG NUMBER
ENCLOSURE AND CHASSIS
ELECTRICAL
RATING
MAIN LUG
RATING
NUMBER OF
BRANCH POLES
ENCLOSURE
BOX SIZE
MAIN WIRE
RANGE
A
B
B
C
C
D
100
100
225
225
100
225
6
12
12
18
21
27
B7P20 - 306 - ML100
B7P29 - 312 - ML100
B7P29 - 312 - ML225
B7P41 - 318 - ML225
B7P41 - 321 - ML100
B7P50 - 327 - ML225
K
K
L
L
K
M
3 Phase
4 Wire
with solid neutral
up to 600 VAC
c
NOTE: Main breaker panel includes main breaker and its price in basic enclosure part number. Refer to page DE15 for branch breaker ordering information.
See page DE16 for enclosure dimensions.
DE14
B7L/B7P DISTRIBUTION EQUIPMENT
BRANCH BREAKERS ACCESSORIES/OPTIONS
Branch Breaker Notes:
1) B7L panels are factory drilled for maximum num-
ber of single pole branch breaker handles and
B7P for maximum number of 3 pole branch
breaker handles as standard.
2) Part numbers illustrated above include external
handle, trip mechanism, locking tab and internal
breaker. Refer to page DE12 for complete order-
ing information and examples.
3) Space = External handle, shaft and trip mecha-
nism installed to allow for future installation of
breaker.
4) Ground Fault & Equipment protection breakers
include external pushbutton for each breaker to
test ground fault sensing circuit and the mechan-
ical operation of breaker.
5) Switch Neutral Breaker note. A two pole breaker
has one pole for breaking from main buss and
one pole that breaks neutral. Three pole breaker
consists of two poles for breaking from main
buss and one pole that breaks neutral.
MODIFICATIONS
SU3 Drain and breather1NEMA 3, 7CD, 9 EFG
SU3B Drain and breather1NEMA 3, 7BCD, 9EFG
KIT-251 Grounding kit, 100 AMP
KIT-252 Grounding kit, 225 AMP
B7SF Special baked epoxy finish
B7EYEBOLT Eye bolts for ease of installation2
B7ML225 Change 100 amp buss to 225 amp B7P series
B7MLBTM Main lugs at bottom
B7SPNPT Change standard conduit size and location
B7GSN Kit to ground neutral bar
* To be ordered as separate item with notation on order for assembly into enclosure.
1Installation of drain and breather will void the NEMA 4-4X Rating of panelboard.
Drain and breather will be installed into a standard conduit opening provided in box.
2Lifting eyebolts are installed in two conduit openings located in top of box
and are to be removed after installation.
DESCRIPTION
CATALOG NUMBER
NUMBER OF
POLES PER
BREAKER
TRIP AMP
RATING
B7L SERIES LIGHTING PANEL
BAB FRAME
STANDARD
BAB FRAME
SWITCH
NEUTRAL
QBGF GROUND
FAULT 5MA
QBGEP
EQUIPMENT
PROTECTION 30MA
EHD FRAME
480 VAC MAX.
FDB FRAME
600 VAC MAX.
B7P SERIES POWER PANEL
B7BLA1000
B7BLA1015
B7BLA1020
B7BLA1030
B7BLA1040
B7BLA1050
B7BLA1060
B7BLA1070
B7BLA1100
B7BLA2000
B7BLA2015
B7BLA2020
B7BLA2030
B7BLA2040
B7BLA2050
B7BLA2060
B7BLA2070
B7BLA2090
B7BLA2100
B7BLB3000
B7BLB3015
B7BLB3020
B7BLB3030
B7BLB3040
B7BLB3050
B7BLB3060
B7BLB3070
B7BLB3090
B7BLB3100
B7BLF2000
B7BLF2015
B7BLF2020
B7BLF2030
B7BLF3000
B7BLF3015
B7BLF3020
B7BLF3030
B7BLC1000
B7BLC1015
B7BLC1020
B7BLC1030
B7BLC1040
B7BLC2000
B7BLC2015
B7BLC2020
B7BLC2030
B7BLC2040
B7BLC2050
B7BLE1000
B7BLE1015
B7BLE1020
B7BLE1030
B7BLE1040
B7BLE2000
B7BLE2015
B7BLE2020
B7BLE2030
B7BLE2040
B7BLE2050
B7BPK1000
B7BPK1015
B7BPK1020
B7BPK1030
B7BPK1040
B7BPK1050
B7BPK1060
B7BPK1070
B7BPK1090
B7BPK1100
B7BPK2000
B7BPK2015
B7BPK2020
B7BPK2030
B7BPK2040
B7BPK2050
B7BPK2060
B7BPK2070
B7BPK2090
B7BPK2100
B7BPK3000
B7BPK3015
B7BPK3020
B7BPK3030
B7BPK3040
B7BPK3050
B7BPK3060
B7BPK3070
B7BPK3090
B7BPK3100
B7BPL2000
B7BPL2015
B7BPL2020
B7BPL2030
B7BPL2040
B7BPL2050
B7BPL2060
B7BPL2070
B7BPL2090
B7BPL2100
B7BPL3000
B7BPL3015
B7BPL3020
B7BPL3030
B7BPL3040
B7BPL3050
B7BPL3060
B7BPL3070
B7BPL3090
B7BPL3100
B7BPL3110
B7BPL3125
B7BPL3150
(1) Single
Phase
120 Volt
(2) Double
Pole
120/240 Volt
(3) Three
Pole
120/240 Volt
SPACE
15
20
30
40
50
60
70
90
100
SPACE
15
20
30
40
50
60
70
90
100
SPACE
15
20
30
40
50
60
70
90
100
110
125
150
BRANCH CIRCUIT BREAKERS
BAB FRAME HID
HIGH INTENSITY
DISCHARGE
B7BLD1000
B7BLD1015
B7BLD1020
B7BLD1030
B7BLD1040
B7BLD1050
B7BLD1060
B7BLD2000
B7BLD2015
B7BLD2020
B7BLD2030
B7BLD2040
B7BLD2050
B7BLD2060
DE
DE15
B7L/B7P DISTRIBUTION EQUIPMENT
CATALOG LOGIC/WIRING/DATA DIMENSIONS
Catalog Logic- for basic Panelboard Enclosures
B7 L 20 - 1 - 12 ML 100
1-Single Phase
3-Three Phase
Nominal Inside Length
of Box 20-29-41-50
L-Lighting
P-Power
Constant For PRISM
Series Enclosures Mains Amp Rating
NOTE: Change if lower amperage main breaker is required,
Example MBB60 for 60 AMP main.
Number Of Branch Poles
Mains ML - Main Lugs Only
MBB Main Breaker BAB
MBC ED
MBE EHD
MBF FDB
MBJ JD
DIMENSIONS
A
B
C
D
MXB-13207
MXB-13297
MXB-13417
MXB-13507
24-3/4"(629)
33-3/8"(848)
45-3/8"(1153)
54-3/8"(1381)
13"(330)
21"(533)
33"(838)
42"(1067)
2"
2-1/2"
3"
3"
1"
1"
1"
1"
6-7/8"(175)
10-7/8"(276)
16-7/8"(429)
21-3/8"(543)
2
2
2
2
3
3
3
3
3
4
5
6
4
5
6
7
ABCD
CONDUIT QUANTITY
CONDUIT SIZE
ENCLOSURE BOX SIZE
BASE BOX NUMBER1
LETTER Z
XYA B,C,D
Main Lug Only
Three Phase 4-Wire
Solid Neutral
120/208 VAC
Main Lug Only
Single Phase 3-Wire
Solid Neutral
120/240 VAC
Back Feed
Main Breaker
Three Phase 4-Wire
Solid Neutral
120/208 VAC
Back Feed
Main Breaker
Single Phase 3-Wire
Solid Neutral
120/240 VAC
Vertical
Main Breaker
Three Phase 4-Wire
Solid Neutral
120/208 VAC
Vertical
Main Breaker
Single Phase 3-Wire
Solid Neutral
120/240 VAC
EFGHIJKLM N
#12-#1 #6-250MCM #12-1/0 #14-1/0 2/0-250MCM #14-#1 #6-2/0 #6-4/0 #2-4/0 #2-2/0
Wiring Diagrams B7L Series
WIRE SIZES
(Note: B7P Series are single column)
Dimensions
1See pages DE13 and DE14 for complete enclosure ordering information.
DE16
D2L/D2PC SERIES DISTRIBUTION EQUIPMENT
FACTORY SEALED CIRCUIT BREAKER PANEL-
FEATURES-SPECIFICATIONS
Class I, Div. 2, Groups B,C,D
Class I, Zone 2, Groups IIB+H2, IIA
Class II, Div. 2, Groups F,G
Class III, Div. 1 & 2
NEMA, CSA Type 3, 4 (4X Optional)
Applications
Hazardous areas due to the potential
of explosive gas atmospheres, com-
bustible dusts or easily ignited fibers
or flyings and areas subjected to cor-
rosive or harsh chemicals, weather or
dampness
Petroleum refineries, chemical or
petrochemical facilities with indoor
or outdoor processes
Applications requiring overcurrent
and short circuit protection of light-
ing, appliances heating or motor
circuits
Features
Factory Seal between breaker enclo-
sure and termination box eliminates
the need for external sealing
Gasketed covers assure NEMA/CSA
Type 4, 4X rated protection for hose-
down and corrosion
Standard Electrical Components:
D2L–Cutler-Hammer QC Breakers
D2CP–Cutler-Hammer GHC & GCH
Breakers
Main distribution block, branch termi-
nal block, neutral and ground bar are
located in termination enclosure
Main Lugs. Mechanical solderless
type, approved for CU or AL
conductors
Solid neutral standard. Single phase,
3 wire or three phase 4 wire
Main and branch circuit breaker han-
dles can be padlocked in “on”
or “off” position
Top or bottom feed panels available
Breaker chamber hinged cover with
quick release – captivated bolts
Termination enclosure has hinged
cover with quick release latch for
easy opening
Termination enclosure supplied with-
out conduit openings for easy field
punching of incoming and outgoing
entries
Line and load side of breakers in
breaker chamber are factory wired to
terminal blocks in termination enclo-
sure and sealed at the factory
Breaker enclosure is drilled and
plugged for maximum number of
circuits to permit field addition of
unused branch spaces
Panel Selection Factors
Basic information required when
specifying panelboards is as follows:
Service Requirements – Voltage,
phases and frequency
Interrupting capacity
Amperage Rating of Main (Lugs only
or Breaker)
Branch Breaker Requirements
Type
Number
Poles
Amperage
GFCI Requirements
Ordering Information
Specifying and ordering a complete
panelboard assembly requires the
selection of three components
1. Basic Panel
2. Branch Breakers
3. Modifications if Required
This method of cataloguing permits a
wide variety and maximizes circuit flexi-
bility in the Killark panelboard series.
Standard Materials
Breaker Enclosure: Copper-free cast
aluminum (less than 4/10 of 1%)
Terminal enclosure: Steel powder
coated. (Optional stainless steel or
fiberglass for 4X ratings)
Cover bolts: Type 316 stainless steel
SUFFIX NUMBER DESCRIPTION
SU3 Drain and breather C&D1
SU3B Drain and breather B,C,D12
D2SF Powder paint on breaker box
D2MLBTM Invert with terminal box
located on bottom
D2STST Substitute with stainless
steel termination box
D2FG Substitute with fiberglass
termination box
B7GSN Kit to ground neutral
bar
D2CA Substitute with cast aluminum
termination box
MODIFICATIONS
1Installation of drain breather will void the
NEMA 4-4x rating of panelboard.
2Not CSA
Classified — File E83969
Certified — File LR11713
DE
DE17
D2L SERIES DISTRIBUTION EQUIPMENT
FACTORY SEALED CIRCUIT BREAKER PANELBOARDS
FEATURES-SPECIFICATIONS
D2L CIRCUIT BREAKER RATINGS
CUTLER-HAMMER TYPE QC CIRCUIT BREAKERS
TYPE POLES VOLTS AMPERES
SYMMETRICAL
1 120
QC 2 120/240 10,000 AIC
3 240
QCSWN 1 120/240 10,000 AIC
2 120/240
QCGF 1 120
2 120/240 10,000 AIC
QCGFEP 1 120
2 120/240 10,000 AIC
QC*D 1 120
QC*D 2 120/240 10,000 AIC
D2L PANELBOARDS WITHOUT MAIN BREAKER (MAIN LUGS ONLY) LESS BRANCH BREAKERS
ELECTRICAL
RATING
NUMBER OF
BRANCH POLES
MAIN LUG
RATING AMPS
CATALOG NUMBER
BASIC ENCLOSURES
MAIN WIRE
RANGE
PANEL
SIZE
Single Phase
3 Wire with
Solid Neutral
120/240 VAC
12
24
36
42
100
225
225
225
D2L-112-ML100
D2L-124-ML225
D2L-136-ML225
D2L-142-ML225
M
N
N
P
A
B
C
D
Three Phase
4 Wire with
Solid Neutral
120/208 VAC
12
24
36
42
100
225
225
225
D2L-312-ML100
D2L-324-ML225
D2L-336-ML225
D2L-342-ML225
M
N
N
P
A
B
C
D
D2L PANELBOARDS WITH MAIN BREAKER LESS BRANCH BREAKERS
ELECTRICAL
RATING
NUMBER
OF BRANCH
POLES AMPS FRAME
CATALOG NUMBER
BASIC ENCLOSURES
MAIN WIRE
RANGE
PANEL
SIZE
Single Phase
3 Wire with
Solid Neutral
120/240 VAC
10
22
34
42
100
100
100
225
D2L-110-MBQ100
D2L-122-MBQ100
D2L-134-MBQ100
D2L-142-MBED225
M
N
N
N
A
B
C
D
Three Phase
4 Wire with
Solid Neutral
120/208 VAC
9
21
33
42
100
100
100
225
D2L-309-MBQ100
D2L-321-MBQ100
D2L-333-MBQ100
D2L-342-MBED225
M
N
N
N
QC
QC
QC
ED
QC
QC
QC
ED
A
B
C
D
NOTE: To substitute a lower amperage main breaker change last three digits of catalog number
to desired amperage.
Example: For a 50 amp main breaker part number = D2L-309-MBQ050
See page DE20 for Branch Breaker Selection
See page DE21 for Dimensions, Wire Range Chart and Wiring Diagrams.
Panels are constructed with Terminal Box on Top for Top Feed.
If Bottom Feed is required order modification D2MLBTM for inverted panel with
Terminal Box on Bottom.
Catalog Numbers on this page are for
the basic Termination Enclosure with
distribution, neutral, ground bar and
terminal blocks plus a Breaker
Enclosure with internal pan. Enclosures
are connected together with factory
poured sealing chambers and mounted
on aluminum frame for wall mounting.
External breaker handles and internal
branch breakers are not included and
must be ordered as separate items for
factory installation. (See page DE20)
MAIN BREAKER
Class I, Div. 2, Groups B,C,D
Class I, Zone 2, Groups IIB+H2, IIA
Class II, Div. 2, Groups F,G
Class III, Div. 1 & 2
NEMA, CSA Type 3, 4 (4X Optional)
Classified — File E83969
Certified — File LR11713
DE18
D2PC SERIES DISTRIBUTION EQUIPMENT
FACTORY SEALED LIGHTING/POWER PANELBOARDS
FEATURES-SPECIFICATIONS
Catalog Numbers on this page are for
the basic Termination Enclosure with
distribution, neutral, ground bar and
terminal blocks plus a Breaker Enclosure
with internal pan. Enclosures are
connected together with factory poured
sealing chambers and mounted on alu-
minum frame for wall mounting.
External breaker handles and internal
branch breakers are not included and
must be ordered as separate items for
factory installation. (See page DE20)
CUTLER-HAMMER CIRCUIT BREAKER RATINGS FOR D2PC PANEL
TYPE
NUMBER
OF
POLES
MAXIMUM
VOLTS
AC DC
AMPERES SYMMETRICAL
277
VAC
347
VAC
277/480
VAC
347/600
VAC
125
VDC
250
VDC
GHC
GCH
1
2&3
277
277/480Y
125
250
14,000
14,000
14,000
14,000
14,000
NOTE: GCH Breakers are CSA only.
PANELBOARDS WITHOUT MAIN BREAKER (MAIN LUGS ONLY) LESS BRANCH BREAKERS
ELECTRICAL
RATING
NUMBER OF
BRANCH POLES
MAIN LUG
RATING AMPS
CATALOG NUMBER
BASIC ENCLOSURES
MAIN WIRE
RANGE
PANEL
SIZE
Three Phase
4 Wire with Solid
Neutral up to
480Y/277 VAC
600Y/347 VAC
12
24
36
42
100
225
225
225
D2PC-312-ML100
D2PC-324-ML225
D2PC-336-ML225
D2PC-342-ML225
M
N
N
P
E
F
G
H
PANELBOARDS WITH MAIN BREAKER LESS BRANCH BREAKERS
ELECTRICAL
RATING
NUMBER
OF BRANCH
POLES
MAIN BREAKER CATALOG NUMBER
BASIC ENCLOSURES
MAIN WIRE
RANGE
PANEL
SIZE
MAX
VOLTS AMPS FRAME
9
9
21
21
33
33
42
100
100
100
100
100
100
225
480Y/277
600Y/347
480Y/277
600Y/347
480Y/277
600Y/347
600Y/347
D2PC-309-MBGH100
D2PC-309-MBGC100
D2PC-321-MBGH100
D2PC-321-MBGC100
D2PC-333-MBGH100
D2PC-333-MBGC100
D2PC-342-MBJ225
M
M
N
N
N
N
N
E
E
F
F
G
G
H
Three Phase
4 Wire with
Solid Neutral
480Y/277 VAC
600Y/347 VAC
GHC
GCH
GHC
GCH
GHC
GCH
JDB
NOTE: To substitute a lower amperage main breaker change last three digits of catalog number
to desired amperage.
Example: For a 50 amp main breaker part number = D2PC-309-MBGH050
See page DE20 for Branch Breaker Selection
See page DE21 for Dimensions, Wire Range Chart and Wiring Diagrams.
Panels are constructed with Terminal Box on Top for Top Feed.
If Bottom Feed is required order modification D2MLBTM for inverted panel with Terminal Box on Bottom.
Note special wiring conditions: GHC 480Y/277 circuit breakers are not suitable for 3 phase Delta (480)
GCH 600Y/347 circuit breakers are not suitable for 3 phase Delta (600)
GCH Rating is for CSA only not UL.
600/480V Factory Sealed Power
Panels available up to 42 circuits
(MLO) as shown. Consult factory
for ordering information.
1
2&3
347
347/600Y
125
250
10,000
10,000
14,000
14,000
Class I, Div. 2, Groups B,C,D
Class I, Zone 2, Groups IIB+H2, IIA
Class II, Div. 2, Groups F,G
Class III, Div. 1 & 2
NEMA, CSA Type 3, 4 (4X Optional)
Classified — File E83969
Certified — File LR11713
DE
DE19
D2L/D2PC SERIES DISTRIBUTION EQUIPMENT
FACTORY SEALED CIRCUIT BREAKER PANELBOARDS
FEATURES-SPECIFICATIONS
BRANCH CIRCUIT BREAKER SELECTION FOR D2L & D2PC FACTORY SEALED PANELBOARDS
NUMBER OF
POLES PER
BREAKER
TRIP AMP
RATING
D2L SERIES LIGHTING PANEL
QC FRAME
STANDARD
QC FRAME
SWITCHED
NEUTRAL
QCFG GROUND
FAULT 5 MA
QCGFEP EQUIPMENT
PROTECTION 30 MA
GHC FRAME
277/480Y
VAC MAX
D2PC SERIES POWER PANEL
GCH FRAME
347/600Y
VAC MAX
(1) Single
Pole
(2) Double
Pole
(3) Three
Pole
Space
15
20
30
40
50
60
70
90
100
Space
15
20
30
40
50
60
70
90
100
Space
15
20
30
40
50
60
70
90
100
D2BLA1000
D2BLA1015
D2BLA1020
D2BLA1030
D2BLA1040
D2BLA1050
D2BLA1060
D2BLA1070
D2BLA1090
D2BLA1100
D2BLA2000
D2BLA2015
D2BLA2020
D2BLA2030
D2BLA2040
D2BLA2050
D2BLA2060
D2BLA2070
D2BLA2090
D2BLA2100
D2BLA3000
D2BLA3015
D2BLA3020
D2BLA3030
D2BLA3040
D2BLA3050
D2BLA3060
D2BLA3070
D2BLA3090
D2BLA3100
D2BLF2000
D2BLF2015
D2BLF2020
D2BLF2030
D2BLF3000
D2BLF3015
D2BLF3020
D2BLF3030
D2BLC1000
D2BLC1015
D2BLC1020
D2BLC1030
D2BLC1040
D2BLC2000
D2BLC2015
D2BLC2020
D2BLC2030
D2BLC2040
D2BLC2050
D2BLE1000
D2BLE1015
D2BLE1020
D2BLE1030
D2BLE1040
D2BLE1050
D2BLE2000
D2BLE2015
D2BLE2020
D2BLE2030
D2BLE2040
D2BLE2050
D2BGHC1000
D2BGHC1015
D2BGHC1020
D2BGHC1030
D2BGHC1040
D2BGHC1050
D2BGHC1060
D2BGHC1070
D2BGHC1090
D2BGHC1100
D2BGHC2000
D2BGHC2015
D2BGHC2020
D2BGHC2030
D2BGHC2040
D2BGHC2050
D2BGHC2060
D2BGHC2070
D2BGHC2090
D2BGHC2100
D2BGHC3000
D2BGHC3015
D2BGHC3020
D2BGHC3030
D2BGHC3040
D2BGHC3050
D2BGHC3060
D2BGHC3070
D2BGHC3090
D2BGHC3100
D2BGCH1000
D2BGCH1015
D2BGCH1020
D2BGCH1030
D2BGCH1040
D2BGCH1050
D2BGCH1060
D2BGCH1070
D2BGCH1090
D2BGCH1100
D2BGCH2000
D2BGCH2015
D2BGCH2020
D2BGCH2030
D2BGCH2040
D2BGCH2050
D2BGCH2060
D2BGCH2070
D2BGCH2080
D2BGCH2100
D2BGCH3000
D2BGCH3015
D2BGCH3020
D2BGCH3030
D2BGCH3040
D2BGCH3050
D2BGCH3060
D2BGCH3070
D2BGCH3090
D2BGCH3100
NOTES: 1) Above part numbers include external handle, trip mechanism, locking tab and internal branch
circuit breaker.
2) Refer to page DE17 for complete ordering information and examples.
3) Refer to pages DE18 and DE19 for maximum voltage and ratings of circuit breakers.
4) Space = External handle, trip mechanism installed to allow for future installations of breakers.
5) Ground Fault and Equipment protection breakers include external button for test purpose.
6) 15 and 20 ampere, 1 pole GHCHID are SWD rated.
CATALOG NUMBER
Class I, Div. 2, Groups B,C,D
Class I, Zone 2, Groups IIB+H2, IIA
Class II, Div. 2, Groups F,G
Class III, Div. 1 & 2
NEMA, CSA Type 3, 4 (4X Optional)
Classified — File E83969
Certified — File LR11713
GHCHID FRAME
277/480Y HIGH
INTENSITY DISCHARGE
D2BGHCD1000
D2BGHCD1015
D2BGHCD1020
QC FRAME HID
HIGH INTENSITY
DISCHARGE
D2BLD1000
D2BLD1015
D2BLD1020
D2BLD1030
D2BLD1040
D2BLD1050
D2BLD1060
D2BLD2000
D2BLD2015
D2BLD2020
D2BLD2030
D2BLD2040
D2BLD2050
D2BLD2060
DE20
D2L/D2PC SERIES DISTRIBUTION EQUIPMENT
FACTORY SEALED CIRCUIT BREAKER PANELBOARDS
FEATURES-SPECIFICATIONS
WIRE RANGE CHART
REFERENCE
LETTER MAIN WIRE RANGE
M2/0-#14AWG
N
P
350MCM-#6AWG
400MCM-#6AWG
Standard Panelboard Wiring Diagram
DIMENSIONS FOR PANELS WITH STANDARD STEEL PAINTED TERMINAL ENCLOSURES
A 12 16" 20-1/8" 11" 8-7/16" 33-27/32" 31-1/2" 16" 15-1/4" 8-15/16" 35-3/8"
B 24 20" 21-1/4” 11-7/32" 10-7/16” 46-31/32" 44-5/8" 24" 20-3/8" 10-15/16" 48-1/2"
C 36 20" 22-1/8" 14-1/16" 10-7/16” 55-27/32" 53-1/2" 24" 29-1/4" 11-3/8" 57-3/8"
D 42 24" 23-3/16" 14-3/8" 10-7/16" 67" 64-5/8" 24" 40-3/8" 13-1/4" 68-17/32"
E 12 16" 23-1/4" 11-21/32" 8-7/16" 35" 32-5/8" 16" 16-3/8" 12-7/8" 36-1/2"
F 24 20" 24-1/8” 12-1/16" 10-7/16” 49-27/32" 47-1/2" 24" 23-1/4" 13-3/8" 51-3/8"
G 36 20" 23-3/16" 13-25/32" 10-7/16” 54-31/32" 52-5/8" 24" 28-3/8" 13" 56-1/2"
H 42 24" 23-3/16" 14-3/8" 10-7/16" 67" 64-5/8" 24" 40-3/8" 13-1/4" 68-17/32"
PANEL
SIZE
MAXIMUM
CIRCUITS AB C D EFG HJL
DIMENSION CHANGE FOR PANELS WITH ALTERNATE TERMINAL ENCLOSURES
A 20 16 24 14
B 20 24 24 24
C 20 24 2 4 24
D 24 24 24 24
E 20 16 24 14
F 20 24 24 24
G 20 24 2 4 24
H 24 24 24 24
PANEL
SIZE
D2 STAINLESS STEEL OPTION D2 FIBERGLASS OPTION
A G AG
Class I, Div. 2, Groups B,C,D
Class I, Zone 2, Groups IIB+H2, IIA
Class II, Div. 2, Groups F,G
Class III, Div. 1 & 2
NEMA, CSA Type 3, 4 (4X Optional)
Classified — File E83969
Certified — File LR11713
DE
DE21
EXBLI/EXBPI SERIES DISTRIBUTION EQUIPMENT
IEC CIRCUIT BREAKER PANELBOARDS
DE22
#C22.2 No. 30-M1986 - Explosion Proof Enclosure for
use in Class I Hazardous Locations. File #LR11716
CENELEC II 2 GD
PTB 07 ATEX 1025U (Empty Housing)
PTB 07 ATEX 1024x (Enclosures w/Controls)
IEC Ex 07.0022U
IEC Ex 07.0023
Class I, Div. 1 & 2, Groups B1,C,D
Class I, Zones 1 & 2, Groups llB+H2,llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X2, 7(B,C,D), 9(E,F,G)
CENELEC/ATEX/IEC - Ex
Ex d IIB + H2 T5 or T6
Ex tD A21 IP66
Ta< +60OC
ATEX Certified
#UL886 - Outlet Boxes and Fittings for use in Hazardous
(Classified) Locations. File E10514
FEATURES-SPECIFICATIONS
Introduction
New from Killark are IEC rated
panelboards with type UL 489 series
miniature circuit breakers (MCB) and
busbar system.
For the world wide market, the
breakers carry UL, CSA, IEC, CE and
many other agency approvals and
certifications.
Available as 6, 12, 18, 24, 36, 54 or 72
circuits with main lug and/or main
breaker.
Consult factory for specific needs.
Applications
Locations made hazardous due to
the presence of flammable gases or
vapors, combustible dust, or easily
ignitable fibers and flyings, and
areas which are subject to corrosion,
weather and dampness
Petroleum Refineries, Chemical and
Petrochemical plants with indoor and
outdoor processes
Global applications (ATEX)
Enclosures are available for global
applications with “CEN” suffix.
Assemblies that are modified to
CENELEC/ATEX standards main-
tain their North American certifica-
tions
Features
Copper-Free Cast Aluminum
Construction. High strength, lighter in
weight, corrosion resistant
Fewer Cover Bolts. Computer-aided
design lessens the number of cover
bolts by eliminating corner bolts.
Reduces installation and mainte-
nance time
Gasketed covers assure NEMA/CSA
Type 4, 4X rated protection for hose-
down and corrosion
Main distribution block, branch ter-
minal block, neutral and ground bar
are located in termination enclosure
Main Lugs. Mechanical solderless
type, approved for CU or AL con-
ductors
Solid neutral standard. Single phase,
3 wire or three phase 4 wire
Main and branch circuit breaker han-
dles can be padlocked in “on” or
“off” position
Panel Selection Factors
Basic information required when
specifying panelboards is as follows:
Service Requirements - Voltage,
phases and frequency
Interrupting capacity
Amperage Rating of Main (Lugs only
or Breaker)
Branch Breaker Requirements
-Type
-Number
-Poles
-Amperage
-RDC Requirements
Catalog Logic
See page DE23 for panelboard catalog
number logic for basic enclosures.
w/o main breaker
w/main breaker
1Conduits must be sealed within 18” for
Group B applications.
2NEMA 4X with optional SU-1 modification
#UL698 & #UL1203 - Explosion Proof and Dust Ignition
Proof Electrical Equipment. Files #E83969 & E12379
EXBLI/EXBPI SERIES DISTRIBUTION EQUIPMENT
IEC CIRCUIT BREAKER PANELBOARDS
DE
DE23
Catalog Logic- for basic IEC Panelboard Enclosures
EXB L I - 3 6 ML 80 1
1-Single Phase
3-Three Phase
IEC Type
L-Lighting 240V
P-Power 480Y/277
Constant For Series Main Breaker Trip Amps
15A to 150A
Number Of Branch Poles
6, 12, 18, 24, 36, 54, or 72
ML - Main Lug (max. 80A)
MB - Main Breaker
Consult factory with
branch breaker requirements
CATALOG # of CIRCUITS
NUMBER CIRCUITS
W/MAIN BREAKER ABCQTY C FGH I JK LM
EXB-10146 N34 6 1-1/2” 1” 3/4” 3 15.25 19.25 8.9 4.94 8.94 12.94 16.94 0.25
EXB-12186 N34 12 1” 1-1/2” 3/4” 6 16.38 22.38 9.06 6.94 12.88 14.94 20 . 8 8 0.25
EXB-12246 N34 18 1” 1-1/2” 3/4” 9 16.38 28.38 9.32 6.94 12.88 14.94 26 . 8 8 0.25
EXB-18186 N34 24 1-1/2” 1” 3/4” 12 23.25 23.25 10 13.38 13.38 2 1 . 3 8 21.38 0 . 25
EXB-18148 N34 36 1-1/2” 1” 3/4” 18 22.38 28.38 11.75 13 19 21 27 0.25
EXB-18368 N34 54 1” 2-1/2” 3/4” 27 22.38 40.38 12.38 13.25 31.5 2 1 3 9 . 5 0.25
EXB-24368 N34 72 1” 2-1/2” 3/4” 36 29.25 41.25 12.4 19.56 31.56 27.56 39.56 0.25
EXB DIMENSIONS
CONDUIT TOP & BOTTOM (NPT) EXTERNAL DIMENSION (NI) MOUNTING DIMENSIONS (INCHES)
GCBB SERIES DISTRIBUTION EQUIPMENT
CIRCUIT BREAKER LOAD CENTERS
DE24
FEATURES-SPECIFICATIONS
Applications
Indoor or outdoor hazardous areas
where flammable gases or vapors,
combustible dusts, or easily ignitable
fibers or flyings may be present
Provides overcurrent and short
circuit protection of branch lighting,
heating and appliance circuits
Features
Compact rectangular enclosure with
threaded cover allows easy access
GCBB/2GCBB provided with two 3/4"-
14 NPT drilled and tapped conduit
openings, one top and one bottom
3GCBB provided with three 3/4" - 14
NPT drilled and tapped conduit
openings, one top and two bottom
4GCBB provided with four 3/4"-14
NPT drilled and tapped conduit
openings, two top and two bottom
Cutler-Hammer Type QC Quicklag
Circuit Breakers (These Assemblies
include the Breakers as indicated)
Push pull handle mechanism oper-
ates circuit breakers
Handle mechanism supplied as stan-
dard with “Lockout” in off position
Enclosures are made from copper-
free cast aluminum alloy (less than
4/10 of 1%)
Special combinations of breaker
amperage are available, consult
factory for details
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+H2, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3R, 7(B,C,D) 9(E,F,G)
SUFFIX NUMBER DESCRIPTION
SU3 Drain and breather
KIT-251 150 amp ground lug
KIT-252 250 amp ground lug
SU17 Solid neutral
MODIFICATIONS
FRAME VOLTAGE AMPS AMPS
SIZE ASYMMETRICAL SYMMETRICAL
QC 120/240 VAC 10,000 10,000
QC 240 VAC 10,000 10,000
QC 24/48 DC 5,000 5,000
QC 62/80 DC 3,800 3,800
INTERRUPTING RATINGS
CATALOG NUMBER
ONE 1-POLE ONE 2-POLE ONE 3-POLE TWO 1-POLE TRIP
120 VOLTS AC 120/240 VOLTS AC 240 VOLTS AC 120/240 VOLTS AC AMPS
GCBB-15Q1 GCBB-15Q2 GCBB-15Q3 2GCBB-15Q1 15
GCBB-20Q1 GCBB-20Q2 GCBB-20Q3 2GCBB-20Q1 20
GCBB-30Q1 GCBB-30Q2 GCBB-30Q3 2GCBB-30Q1 30
GCBB-40Q1 GCBB-40Q2 GCBB-40Q3 2GCBB-40Q1 40
GCBB-1Q GCBB-2Q GCBB-2Q 2GCBB-1Q Enclosure only
GCBB 15/40A TRIP QUICKLAG
Dimensions
Listed - File E83969
See files for details or call Killark.
CATALOG NUMBER
THR E E 1-POLE FO UR 1-POLE T W O 2-POLE ONE 1-POLE ONE 3-POLE TRIP
120 V O LTS A C 120 VOLTS AC 1 2 0/240 VOLTS AC 120/240 VOLTS AC AMPS
3GCBB-15Q1 4GCBB-15Q1 2GCBB-15Q2 2GCBB-15Q13 15
3GCBB-20Q1 4GCBB-20Q1 2GCBB-20Q2 2GCBB-20Q13 20
3GCBB-30Q1 4GCBB-30Q1 2GCBB-30Q2 2GCBB-30Q13 30
3GCBB-40Q1 4GCBB-40Q1 2GCBB-40Q2 2GCBB-40Q13 40
3GCBB-1Q 4GCBB-1Q 2GCBB-2Q 2GCBB-13Q Enclosure only
GCBB 15/40A TRIP QUICKLAG
GCBB/2GCBB 3GCBB/4GCBB
c
GFCS SERIES DISTRIBUTION EQUIPMENT
GROUND FAULT CONTROL STATION (FACTORY SEALED) DE25
FEATURES-SPECIFICATIONS
DE
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+H2, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 7(B,C,D) 9(E,F,G)
NUMBER OF POLES
1
1
1
1
1
1
2
2
2
2
2
2
MILLIAMP TRIP
5
5
5
30
30
30
5
5
5
30
30
30
BREAKER AMPERAGE
15
20
30
15
20
30
15
20
30
15
20
30
CATALOG NUMBER
GFCS05151
GFCS05201
GFCS05301
GFCS30151
GFCS30201
GFCS30301
GFCS05152
GFCS05202
GFCS05302
GFCS30152
GFCS30202
GFCS30302
GFSC GROUND FAULT CONTROL STATION
Listed - File E83969
Certified - File LR061895-2
Applications
GFCS Series of Ground Fault Control
Stations are used for the additional
safety of personnel, and for equipment
protection in remote areas.
Features
Factory Sealed Ground Fault
Chamber. (Assemblies in Group B
areas must be sealed within 6" of
enclosure. Other area classifications
do not require the use of seals)
1" NPT top and bottom conduit
openings
External Push-to-Test Button and Pilot
Light for monitoring
On-Off-Trip-Reset External Handle
can be locked in On-Off positions
5ma Ground Fault Circuit Breaker
for People Protection. 30ma Ground
Fault circuit Breaker for Equipment
Protection and heat tracing circuits
Electrical Rating-120 VAC (single
pole) 120/240 VAC (two pole) (10,000
AIC)
Material/Finish
Enclosure: Copper-free cast
aluminum (less than 4/10 of 1%)
External Hardware: Stainless Steel
Standard Finish: Electrostatically
applied gray powder epoxy polyester
finish
Dimensions
SWITCHRACK ASSEMBLIES
DE26
FEATURES-SPECIFICATIONS
Applications
Totally wired motor control center
Hazardous locations due to the pres-
ence of flammable gases or vapors,
combustible dust or easily ignitable
fibers and flyings, and areas subject
to corrosion, weather and dampness
Petroleum refineries, chemical and
petrochemical plants with indoor and
outdoor processes
Applications requiring overcurrent
and short circuit protection of light-
ing, appliances, heating and motor
circuits
Features
NEMA 3, 4X (optional) rated for pro-
tection from hose directed water and
corrosion
Completely assembled and wired for
customer connections to load side of
starters and breakers
Single sided or double sided assem-
blies per customer specification
Killark components supplied include
series EXB, B7C, B70, D2L, B7L, GR,
HKB, D2P, B7P, EZ, VM, EM, ENY,
EYS and others
Standard Materials
Enclosures: Copper-free aluminum
(less than 4/10 of 1%)
Bus Enclosure (when supplied) is
painted steel or stainless steel
Frame: Steel (Hot Dipped Galvinized)
or Aluminum. All welded construction
Bus Bars: Copper, bare or insulated
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+H2, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4X, 7(B,C,D) 9(E,F,G)
Ordering Information
Supply one line diagram or bill
of material and Killark will do the rest.
Assembly drawing and wiring
diagram will be supplied for
customer approval.
Basic Data Required
Class_____ Div._____GRPS.______
NEMA Ratings for BUS___________
Incoming Voltage________________
Incoming Amperage______________
Wire: 3w/GND_____ 4w/GND______
Framing: Single Side_____________
Double Side____________
Material: Steel HD/galv.___________
Aluminum______________
Canopy: Yes_______ No__________
Optional Components
Circuit breakers
Automatic Transfer Switch
Motor Starters
Contractors
Junction Boxes
Control Stations
Meter/Instrument Enclosures
Ground Detection
Panelboards
Welding and Convenience
Receptacles
Photo Cells
Light Fixtures
Transformers
Space Heaters
Compliances
All wiring is in accordance with cur-
rent NEC requirements
Each enclosure carries at minimum
one of the following
FM
PRi
PLUGS AND RECEPTACLES INDEX
PR
Section PR
Introduction/Features
Applications.........................................2 - 5
VP/VR/VPR Series
30 amp .....................................................6
VP/VR/VPR Series
60 amp .....................................................7
VP/VR/VPR Series
100 amp ...................................................8
VP/VR/VPR Series
200 amp ...................................................9
VSQ (VWSQ Series NEMA 4)
Interlocked Switched Receptacles ..........10
VSQ-FS Series
Factory Sealed Receptacles ...................11
VBQ Series
Interlocked Breaker Protected
Receptacles.....................................12 - 13
VSI Series
Plugs and Switched Receptacles.....14 - 16
VCR Series
Clean Room Receptacles........................17
KR Series
Introduction.............................................18
KR Series
20, 30 and 60 amp ..........................19 - 21
UGP/UGR Series
Plugs and Receptacles....................22 - 23
Adapter, Grips and Handlamps...............26
UGRC Series
Connector ...............................................24
UGRP Series
Panel Mount Receptacle .........................25
UGRGF Series
GFI Protector Receptacle........................26
UGFI Series
Ground Fault Protector............................27
HAZARDOUS LOCATIONS –
BLADE STYLE
NEMA 4X
HAZARDOUS LOCATIONS –
INTERLOCKED
HAZARDOUS LOCATIONS –
DELAYED ACTION
HAZARDOUS LOCATIONS –
INTERLOCKED
I.E.C. CONFIGURED
VERSAMATE®SERIES PLUGS AND RECEPTACLES
NEMA 4X METALLIC
PR2
FEATURES-SPECIFICATIONS
THE FIRST AND ONLY NEMA 4X RATED LINE
OF METALLIC PLUGS & RECEPTACLES.
VersaMate®metallic pin & sleeve plugs & receptacles are
designed for heavy duty industrial use. These devices sup-
ply power to both fixed and portable electrical equipment
including pumps, generators, welders, vacuums, blowers
and similar apparatus.
Suitable for indoor or outdoor use. Applications include the
wet, cold, hosedown, hazardous or corrosive areas in such
industrial applications as:
Pulp & Paper Mills Breweries
Electrical Power Plants Refineries
Petrochemical Plants Chemical Plants
Wastewater Treatment Grain Facilities
Marine, Docks, Ports Textile Manufacturing
Construction Sites Food Processing Facilities
Standard Materials:
Copper-free aluminum construction with electrostatically
applied epoxy/polyester finish. Contacts are brass with a
patented beryllium copper spring tensioner. External screws
are 316 stainless steel.
Features:
The VersaMate product line includes 30, 60, 100 and 200
Amp plugs, receptacles and connectors with a full range of
back boxes. Popular options include reverse service and
polarization. The VersaMate line is FULLY
INTERCHANGEABLE1with UL1686 configured and listed
devices such as Crouse-Hinds®Arktite®or Appleton®
Powertite®. Standard location receptacle bolt hole patterns
match competitive back boxes so users can upgrade to
VersaMate without changing back boxes in instances where
changing the conduit system is difficult.
600 VAC/250VDC; 50-400 Hertz
NEMA 3, 4, 4X
Class I, Div. 1 & 2, Groups B,C,D;
NEMA 7 B,C,D2
Class l, Zones 1 & 2, llB+H2, llA2
Class ll, Div. 1 & 2, Groups F & G;
NEMA 9 F,G2
Class lll2
1VersaMate®components are UL classified and intermateable with other UL
1686-C1 configured devices (when installed in accordance with instructions
furnished with device). Assemblies containing components from other manu-
facturers would have the NEMA type rating of the lowest rated device.
2See product pages for specific ratings.
Arktite®is a registered trademark of Crouse-Hinds®.
Powertite®is a registered trademark of Appleton®.
Plugs:
Octagonal style (Patented) for a firm and sure
grip when connecting or disconnecting is fea-
tured on both plug and cable connector
bodies. Insulators have high mechanical and
dielectric strength and “Low Arc Tracking.”
“Increased Safety” type box terminals with
gripper ribs securely clamp around conductors.
Funneled conductor entry chambers lead all properly stripped
conductors into terminals simultaneously. NEMA 4X rating
when inserted into VersaMate receptacle and locking ring is
tightened.
Receptacles:
Exclusive Patented “Breech-Lock” cap
serves as either flip lid or screw cover.
Receptacle is NEMA 3R with lid snapped
shut or NEMA 4X with lid turned shut or
when VersaMate plug is inserted and locking
ring tightened. Patented notch in cap arm
holds cap open for easy plug insertion or
maintenance. Patented pin design uses slotted spring clip which
avoids excessive wear while providing continuous electrical pin
to sleeve contact. VersaMate®receptacles use the same
“Increased Safety” terminals and funnel design as
VersaMate®plugs.
Cable Clamping Assembly:
Plugs and cable connectors are
supplied with an exclusive neoprene
“Onion Skin” peel-away type grom-
met. The VersaRange®cable clamp
system captures cable with four
grip points using only two tighten-
ing screws. Clamp guide assembly provides a firm fit over a
wide range of cable diameters. Non-removable set screws pre-
vent clamp guide assembly from backing out. Clamps have
smooth contoured shoulder design to prevent snags or damage
when moving equipment.
Back Boxes:
VersaMate back boxes come in a variety of
mounting styles. Exclusive “blind” recepta-
cle mounting holes prevent moisture from
entering box via thread cavities. Boxes
come with a green grounding screw.
VR/VP VSQ VBQ
VERSAMATE®SERIES PLUGS AND RECEPTACLES
FEATURES AND COMPARISONS PR3
FEATURES-SPECIFICATIONS
PR
“Increased Safety” type termi-
nals reduce connection
fatigue. Screws do not contact
or machine conductor and are
under spring tension to reduce
loosening and pullout.
Conventional screw type
terminals. Screws “machine”
(grind or fray) conductor.
Screws are not under tension
and more easily loosen from
heating and cooling cycles
or from vibration. Screws can
fall out (and be lost) during
initial shipment-requires
reassembly.
“Breech-Lock” design serves
as both flip lid or screw cover
style. Special notch in lid arm
holds cover open to ease plug
insertion or maintenance.
Conventional caps: user
must choose between flip
lid's convenience or screw
cover's better sealing capa-
bilities. Broken chains can
mean lost covers.
Exclusive "Onion Skin" style gas-
ket assures a tight seal around
cable. Skin layers are removed
from a single gasket to adjust for
various cable diameters.
Multiple gaskets require
trial & error sizing to
be sure of best fit and
seal.
Versatile range Cable Clamp
system captures cable at four
grip points using only two
screws. Smooth contoured
design avoids snags when
moving equipment.
Standard clamps squeeze
and pinch cable. Protruding
screws snag or scratch
when moving equipment.
Other clamp systems with
multiple screws are difficult
to tighten evenly.
2
1
3
4
*
*Slip pencil or screwdriver into notch.
TERMINALS
CAP
GASKET
CABLE CLAMP
Wet Panel Power Harsh
VERSAMATE®SERIES PLUGS AND RECEPTACLES
F E AT U R E S
PR4
EXCLUSIVE FEATURES:
Patented Exclusive “Breech-Lock” cap
serves as either flip lid or screw cover
NEMA 3R Rating:
When receptacle cap
is snapped shut
NEMA 4X Rating:
When receptacle cap is
turned shut or with
VersaMate®plug inserted
and ring tightened
Patented
Special notch is designed to
hold cap open for easy field
service or plug insertion with
two free hands
Key user needs were identified from “Focus Groups” comprised of Design Engineers, Contractors,
and Maintenance Personnel. Input from these forums resulted in VersaMate’s unique features.
Keyway prevents
incorrect plug
insertion
O-ring seals
Custom pin design
using slotted spring
clip to provide superior
contact and reliability Sleeve
incorporates
contaminate
relief port
Exclusive neoprene “Onion Skin”
peel-away type gasket for the
ultimate in sealing a variety
of cable sizes
VersaRange®Cable clamp system
captures cable with four grip points
using only two tightening screws.
Provides secure grip without
damaging the cable insulation
Smooth shoulder
contour prevents
snags & hang ups
“Increased safety” type
box terminals provide secure
clamping of conductors
(200A Version is Patented)
Funneled wiring
chamber design for
fast and accurate
conductor insertion
to speed assembly.
All wires can be
inserted at one time
Patented
Body style with octagonal
shape for easy grip
P
P
P
Unique VersaMate®Feature
The VersaMate®Line is designed
for the industrial customer based
on engineering and user surveys
O-ring seals
Funneled wiring chamber
design for fast and
accurate conductor
insertion to speed
assembly. All wires can
be inserted simultaneously
Denotes Patented Feature
P
VERSAMATE®SERIES PLUGS AND RECEPTACLES
N E M A 4 X M E TA L L I C PR5
PR
REVERSE SERVICE: S39
Add suffix S39 for
factory Reverse Service
of receptacles, plugs
or connectors.
Receptacles or connec-
tors are assembled with
plug interiors while
plugs are assembled
with receptacle interiors.
For applications where
the plug is energized
(i.e. from a generator) to
feed a non-energized
receptacle. Prevents
easy contact with energized exposed pins. This conversion
can be performed in the field with a complementary plug &
receptacle (30A to 100A devices shown on pages PR6-8).
200A Amp devices shown on page PR9 are a factory-only
option. Reverse Service is not for hazardous locations.
Style I
In a Style I plug, the cable’s ground conductor is bonded
to the plug housing by means of solderless connector. The
receptacle is grounded by being part of a grounded conduit
system. Upon insertion, detent springs in the receptacle
housing contact and ground the plug housing before current
carrying poles. All poles are current carrying.
GROUNDING:
To minimize the danger of electrical shock when utilizing
portable equipment, the National Electrical Code requires
exposed metal parts be grounded if operated at more than
150 volts to ground. The VersaMate®plug & receptacle sys-
tem is available in two grounding styles. Please note Style I
and II devices cannot be intermated.
POLARIZED OPTION: S37
Add suffix S37 for special polarity.
Can prevent connection between mismatched voltages or
frequencies in areas where devices of the same amperage,
poles and grounding style are used. Receptacle or connector
interiors are rotated 22-1/2° to the right; plug is rotated oppo-
site to match. This is a factory only option.
Style II
In a Style II plug, the cable’s ground conductor is bonded
to the extra grounding pole and to the plug housing via a
bonding jumper. The receptacle has a matching grounding
pole connected to the system ground conductor which is
further tied to the grounded conduit system via a bonding
jumper. Upon insertion, detent springs in the receptacle
housing contact and ground the plug housing; then the
extra long ground pole connects before the current
carrying poles engage. The Style II ground pole makes first
and breaks last.
Standard S37 Option
Typical Application
3W4P Illustrated3W3P Illustrated
VERSAMATE®SERIES PLUGS AND RECEPTACLES
30 AMP NEMA 4X METALLIC
PR6
FEATURES-SPECIFICATIONS
*See page PR5 for more information on these options.
3116
2316
314
22332
31332
31332 22332
Plug
Connector
Receptacle Back Box Dimensions
30 Amp 600VAC/250VDC; 50-400 Hertz
NEMA 3, 4, 4X1
• PLUGS ONLY2:
Class I, Div. 1 & 2, Groups B,C,D; NEMA 7 B,C,D
Class l, Zones 1 & 2, llB+H2, llA
Class ll, Div. 1 & 2, Groups F & G; NEMA 9 F,G; Class lll
30 AMP RECEPTACLES & BACK BOXES
GROUND
STYLE
Style I
Style II
2W2P
3W3P
4W4P
2W3P
3W4P
VR321E2
VR331E2
VR341E2
VR332E2
VR342E2
VRE23
VR321C2
VR331C2
VR341C2
VR332C2
VR342C2
VRC23
VR321D2
VR331D2
VR341D2
VR332D2
VR342D2
VRD23
VR321
VR331
VR341
VR332
VR342
CIRCUIT E3
TYPE
C3
TYPE
D3
TYPE
RECEPTACLE
ONLY
Splice box only3
330 Amp Back Boxes are available in 1/2", 3/4" and 1" conduit sizes.
Size listed for 3/4". For other available sizes, change the BOLD “2” in
either the assembly or box only number to: 1=1/2", 2=3/4", 3=1".
Assembly catalog numbers are listed for ease of ordering or specification
and devices are shipped as components.
30 AMP PLUGS & CONNECTORS
Style I
Style II
2W2P
3W3P
4W4P
2W3P
3W4P
.55 - 1.20 IN
.55 - 1.20 IN
.55 - 1.20 IN
.55 - 1.20 IN
.55 - 1.20 IN
VP3275
VP3375
VP3475
VP3385
VP3485
GROUND
STYLE CIRCUIT GROMMET
RANGE PLUG
CATALOG NUMBER
VPR3255
VPR3355
VPR3455
VPR3365
VPR3465
CONNECTOR
VRD
VRC
VRE
1Components are intermateable & UL classified with other UL1686 config
ured devices (when installed in accordance with instructions furnished
with device). Assemblies containing components from other manufactur
ers would have the NEMA type rating of the lowest rated device.
2Plugs are hazardous suitable when mated with properly rated receptacles
configured to use UL1686 type plugs, such as VersaMate VSQ/VBQ.
– Note, 2, 3 & 4 pole device dimensions are the same.
MODIFICATIONS*
Reverse service for receptacles, plugs & connectors
Polarization for receptacles, plugs & connectors
S39
S37
CATALOG NUMBER DESCRIPTION
CATALOG NUMBER CATALOG NUMBER
CDReceptacle
E
Connector
Wire Range
File No. E10757 Certified File No. LR111846
Regular Stranding: #10 - #6
Extra flex: #10 - #8
Plug
VersaRange®clamps provide
a firm fit for one plug (or con-
nector) over a wide range of
cable diameters (competitors
often need two – requiring
additional sizing decisions).
VERSAMATE®SERIES PLUGS AND RECEPTACLES
60 AMP NEMA 4X METALLIC PR7
FEATURES-SPECIFICATIONS
PR
Receptacle
Plug
Connector
Back Box Dimensions
60 Amp 600VAC/250VDC; 50-400 Hertz
NEMA 3, 4, 4X1
PLUGS ONLY2:
Class I, Div. 1 & 2, Groups B,C,D; NEMA 7 B,C,D
Class l, Zones 1 & 2, llB+H2, llA
Class ll, Div. 1 & 2, Groups F & G; NEMA 9 F,G; Class lll
60 AMP PLUGS & CONNECTORS
Style I
Style II
2W2P
3W3P
4W4P
2W3P
3W4P
.65 - 1.50 IN
.65 - 1.50 IN
.65 - 1.50 IN
.65 - 1.50 IN
.65 - 1.50 IN
VP6275
VP6375
VP6475
VP6385
VP6485
GROUND
STYLE CIRCUIT GROMMET
RANGE PLUG
CATALOG NUMBER
VPR6255
VPR6355
VPR6455
VPR6365
VPR6465
CONNECTOR
1Components are intermateable & UL classified with other UL1686 config-
ured devices (when installed in accordance with instructions furnished
with device). Assemblies containing components from other manufacturers
would have the NEMA type rating of the lowest rated device.
2Plugs are hazardous suitable when mated with properly rated receptacles
configured to use UL1686 type plugs, such as VersaMate VSQ/VBQ.
4Dimensions in ( ) are 3 pole devices; balance are 4 pole.
360 Amp Back Boxes are available in 1", 1-1/4" and 1-1/2"
conduit sizes. Size listed above is 1-1/4". For other available sizes,
change the BOLD “4” in either the assembly or box only number as follows:
3=1", 4=1-1/4", 5=1-1/2". Assembly catalog numbers are listed for ease
of ordering or specification and devices are shipped as components.
Note: 60 Amp receptacles also fit 100 Amp mounting boxes –
see Note4on 100 Amp page PR8.
612
31116 21732 3
(338)(214)
VRC
VRE
VRD
CATALOG NUMBER
*See page PR5 for more information on these options.
MODIFICATIONS*
Reverse service for receptacles, plugs & connectors
Polarization for receptacles, plugs & connectors
S39
S37
CATALOG NUMBER DESCRIPTION
60 AMP RECEPTACLES & BACK BOXES
GROUND
STYLE
Style I
Style II
2W2P
3W3P
4W4P
2W3P
3W4P
VR621E4
VR631E4
VR641E4
VR632E4
VR642E4
VRE46
VR621C4
VR631C4
VR641C4
VR632C4
VR642C4
VRC46
VR621D4
VR631D4
VR641D4
VR632D4
VR642D4
VRD46
VR621
VR631
VR641
VR632
VR642
CIRCUIT E3
TYPE
C3
TYPE
D3
TYPE
RECEPTACLE
ONLY
Splice box only3
CATALOG NUMBER
Connector
VersaRange®clamps provide
a firm fit for one plug (or con-
nector) over a wide range of
cable diameters (competitors
often need two – requiring
additional sizing decisions).
Plug
4
CDReceptacle
E
Wire Range
File No. E10757 Certified File No. LR111846
Regular Stranding: #6 - #4
Extra flex: #6 - #4
VERSAMATE®SERIES PLUGS AND RECEPTACLES
100 AMP NEMA 4X METALLIC
PR8
FEATURES-SPECIFICATIONS
Back Box Dimensions
100 AMP RECEPTACLES & BACK BOXES
GROUND
STYLE
Style I
Style II
2W2P
3W3P
4W4P
2W3P
3W4P
VR1021E5
VR1031E5
VR1041E5
VR1032E5
VR1042E5
VJ57
VR1021C5
VR1031C5
VR1041C5
VR1032C5
VR1042C5
VJC57
VR1021
VR1031
VR1041
VR1032
VR1042
Angle adapter
only VJA100
CIRCUIT E3
TYPE
C3
TYPE
RECEPTACLE
ONLY
Splice box only
w/adapter3 4
100 AMP PLUGS & CONNECTORS
Style I
Style II
2W2P
3W3P
4W4P
2W3P
3W4P
.88 - 1.68 IN
.88 - 1.68 IN
.88 - 1.68 IN
.88 - 1.68 IN
.88 - 1.68 IN
VP10277
VP10377
VP10477
VP10387
VP10487
GROUND
STYLE CIRCUIT GROMMET
RANGE PLUG
CATALOG NUMBER
VPR10257
VPR10357
VPR10457
VPR10367
VPR10467
CONNECTOR
1Components are intermateable & UL classified with other UL1686 config-
ured devices (when installed in accordance with instructions furnished with
device). Assemblies containing components from other manufacturers would
have the NEMA type rating of the lowest rated device.
2Plugs hazardous suitable when mated with properly rated receptacles
configured to use UL1686 type plugs, such as VersaMate VBQ.
5Dimensions in ( ) are 3 pole devices; balance are 4 pole.
3100 Amp Back Boxes are available in 1", 1-1/4", 1-1/2" & 2" conduit sizes.
Size listed above is 1-1/2". For other available sizes, change
the BOLD “5” in either the assembly or box only number as follows:
3=1", 4=1-1/4", 5=1-1/2", 6=2". Assembly catalog numbers are listed for
ease of ordering or specification and devices are shipped as components.
4100 Amp Boxes & Adapters also fit 60 Amp receptacles. Adapter only can
be used to attach receptacle at an angle to a standard sheet metal box.
VJC
EC
*See page PR5 for more information on these options.
MODIFICATIONS*
Reverse service for receptacles, plugs & connectors
Polarization for receptacles, plugs & connectors
S39
S37
CATALOG NUMBER DESCRIPTION
CATALOG NUMBER CATALOG NUMBER
Connector
Receptacle
Plug
Connector
5
Feed through style shown
Plug
VersaRange®clamps
provide a firm fit for one
plug (or connector)
over a wide range of
cable diameters (com-
petitors often need two
– requiring additional
sizing decisions).
Receptacle
Wire Range
File No. E10757 Certified File No. LR111846
Regular Stranding: #4 - #2
Extra flex: #4 - #2
100 Amp 600VAC/250VDC; 50-400 Hertz
NEMA 3, 4, 4X1
PLUGS ONLY2:
Class I, Div. 1 & 2, Groups B,C,D; NEMA 7 B,C,D
Class l, Zones 1 & 2, llB+H2, llA
Class ll, Div. 1 & 2, Groups F & G; NEMA 9 F,G; Class lll
VERSAMATE®SERIES PLUGS AND RECEPTACLES
200 AMP NEMA 4X METALLIC PR9
FEATURES-SPECIFICATIONS
PR
Receptacle
Connector
Back Box Dimensions
200 AMP PLUGS & CONNECTORS
Style I
Style II
3W3P
4W4P
2W3P
3W4P
1.0 - 2.5 IN
1.0 - 2.5 IN
1.0 - 2.5 IN
1.0 - 2.5 IN
VP203512
VP204513
VP203612
VP204612
GROUND
STYLE CIRCUIT GROMMET
RANGE PLUG
CATALOG NUMBER
VPR203112
VPR204113
VPR203212
VPR204212
CONNECTOR
1Components are intermateable & UL classified with Appleton®
Powertite®or Crouse-Hinds®Arktite®devices (when installed in
accordance with instructions furnished with device. Assemblies con
taining components from other manufacturers would have the NEMA
type rating of the lowest rated device.
4Dimensions in ( ) are 3 pole devices; balance are 4 pole.
5200A 3W4P Reverse Service configured “W” Series and VersaMate®
are not intermateable. However, the VersaMate VR20422-S39 recepta-
cle ships with instructions to permanently convert for use with existing
PW-6402X SU39 plugs. Factory only configured plugs to fit old RW64C-
SU39 receptacles may be ordered as VP-PW64026 SU39.
200 Amp Back Boxes are available in dead-end sizes 1-1/2",
2" & 2-1/2" conduit sizes. Dead-end box shown is 2". For other available
dead-end box sizes, change the BOLD “6” in either the dead-end assembly
or box only number as follows: 5=1-1/2", 6=2", 7=2-1/2". Feed through boxes
are available in 2-1/2"; use “R” series adapters as required for smaller sizes
(sold separately). Assembly catalog numbers are listed for ease of ordering
or specification and devices are shipped as components.
Adapter only can be used to attach receptacle at an angle to a standard
sheet metal box.
NOTE: 200A VersaMate receptacle lids secure with wingnuts for N4X environ-
ments when not in use. VersaMate plugs secure with wingnuts and/or
lock-ring collar. This exclusive dual method allows retention of competi-
tive plugs that use either wingnuts or a lock-ring collar.
Receptacle
C
E
VJC
*See page PR5 for more information on these options.
MODIFICATIONS*
Reverse service for receptacles, plugs & connectors
Polarization for receptacles, plugs & connectors
S395
S37
CATALOG NUMBER DESCRIPTION
200 AMP RECEPTACLES & BACK BOXES
GROUND
STYLE
Style I
Style II
3W3P
4W4P
2W3P
3W4P
VR20312E6
VR20412E6
VR20322E6
VR20422E6
VJ68
VR20312C7
VR20412C7
VR20322C7
VR20422C7
VJC78
VR20312
VR20412
VR20322
VR20422
Angle adapter
only VJA200
CIRCUIT E2
TYPE
C2
TYPE
RECEPTACLE
ONLY
Splice box only
w/adapter23
CATALOG NUMBER
200 Amp 600VAC/250VDC; 50-400hertz
NEMA 3 4, 4X1
VersaRange®
clamps provide a
firm fit for one plug
(or connector) over
a wide range of
cable diameters
(competitors often
need two – requir-
ing additional sizing
decisions).
Plug
Wire Range
File No. E10757 Certified File No. LR111846
E213215
Regular Stranding: #1 - 250
Extra flex: #1 - 250
(.653 max conductor diameter)
Plug Connector
2
3
4
VERSAMATE®SERIES PLUGS AND RECEPTACLES
VSQ & VWSQ INTERLOCKED SWITCHED RECEPTACLES
PR10
FEATURES-SPECIFICATIONS
VSQ & VWSQ RECEPTACLES
VSQ Hazardous Location Ratings
Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones I & 2, Groups IIB+H2, IIA
Class II, Div. 1 & 2, Groups F & G
Class lll
NEMA 3, 4, 4X, 7 (B,C,D), 9 (F,G)
VersaMate VSQ & VWSQ Receptacles use
VersaMate Style II plugs found on pages PR6 & PR7
and are compatible with appropriately configured
Crouse-Hinds®Arktite®or Appleton®Powertite®
plugs (when installed in accordance with instruc-
tions furnished with device)
Arktite®is a registered trademark of Crouse-Hinds®.
Powertite®is a registered trademark of Appleton®.
Features
N4X with receptacle lid turned shut
or with plug locking ring tightened
Copper-free aluminum construction
with electrostatically applied poly-
ester/epoxy finish. Handle mecha-
nism is chemical resistant Valox®
(TM General Electric).
Compact size and footprint
Plug Interlock Mechanism for Dead-
front construction. Switch cannot be
turned “ON” without fully inserted
plug. Plug cannot be removed with
switch in “ON” position
Plug held in place when switch is
“Off” for convenience. Pull operated
release mechanism. Plug and wiring
do not have to be twisted or held to
operate switch
Factory Wired Receptacle; easy to
wire line side of switch
Easily visible “On-Off” indicator
handle
“Off” position is padlockable for
maintenance safety
Auxiliary Contact (late-make early-break)
contact rated 10 Amp, 1/3 HP at 125/250
VAC. Can be used for operating pilot
lights or starter coils (standard model only)
Feed-through construction
Horsepower Rated
Internal switch horsepower rated as “motor disconnect”
HORSEPOWER 120 240 480 600
RATINGS (VAC)1
1Ø 25 10 15
3Ø 3 7 . 5 15 20
1Ø – 10 15 20
3Ø – 10 25 30
30A
60A
NOTES: VSQ/VWSQ 30 Amp models come standard with 1" drilled and tapped conduit openings
top and bottom plus two 1" x 3/4" reducers and one 3/4" close-up plug for maximum flexibility.
60 amp models come with 1-1/2" openings top and bottom and one 1-1/2" close-up plug.
VSQ & VWSQ Receptacle covers are NOT interchangeable.
1Refers to internal switch only.
VSQ HAZARDOUS VWSQ N4X ONLY VERSAMATE PLUG
30 2W3P VSQ3023 VWSQ3023 VP3385
3W4P VSQ3034 VWSQ3034 VP3485
60 2W3P VSQ6023 VWSQ6023 VP6385
3W4P VSQ6034 VWSQ6034 VP6485
CATALOG NUMBER
AMPS CIRCUIT
*See page PR5 for more information on this option
MODIFICATIONS*
Polarization for
receptacles, plugs
S37
CATALOG NUMBER DESCRIPTION
VSQ & VWSQ RECEPTACLES
File No. E91049
Certified File No. LR14667
VWSQ for Wet & Corrosive Locations
NEMA 3, 4, 4X
Wire Range
30 Amp Regular Stranding Max #10
60 Amp Regular Stranding Max #4
Dimensions shown are in inches for 30 AMP: 60 Amp dimensions in ( ).
NOTES: Devices have adjustable ductile lugs (vertical or side) for attachment to uneven surfaces.
Ordinary twist type wire connectors are used for final connections on 30A,
60A devices have terminal blocks.
Dimensions
VERSAMATE®SERIES PLUGS AND RECEPTACLES
VSQ-FS FACTORY SEALED INTERLOCKED
SWITCHED RECEPTACLE
PR11
FEATURES-SPECIFICATIONS
PR
Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones I & 2, Groups IIB+H2, IIA
Class II, Div. 1 & 2, Groups F & G
Class lll
NEMA 3, 4, 4X, 7 (B,C,D), 9 (F,G)
Dimensions shown are in inches for 30 AMP. 60 AMP Dimensions in ( ).
Features – same as VSQ1plus:
Factory Sealed Construction elimi-
nates need for conduit sealing at
the device
Saves Installation Time & Labor –
facilitates rework
Switch has factory wired line and
load terminals. Load terminals feed
sealed receptacle as in a standard
VSQ. Line wiring is passed from the
sealed compartment into the wiring
chamber
Receptacles may be loosened from
black box and turned 180 degrees to
adjust for top or bottom feed.
Ordinary twist type wire connectors
are used for final connections on
30A. 60A devices have terminal
blocks
NOTES: VSQ-FS 30 Amp models come standard
with one 1" drilled and tapped conduit openings
into the wiring chamber plus one 1" x 3/4"
reducer.
60 amp models come with one 1" opening.
1VSQ-FS models do not have auxiliary contacts.
VSQ-FS VERSAMATE
HAZARDOUS PLUG
30 2W3P VSQ3023FS VP3385
30 3W4P VSQ3034FS VP3485
60 2W3P VSQ6023FS VP6385
60 3W4P VSQ6034FS VP6485
VSQ - FS RECEPTACLES
Dimensions
MTG.
MTG. (21.0)
157/8
(1811/16)
135/16
(213/16)
31/8
(81/8)
53/4
(119/32)
93/8
(41/32)
33/8
*See page PR5 for more information on this option.
MODIFICATIONS*
Polarization for receptacles
& plugs
S37
CATALOG NUMBER DESCRIPTION
CATALOG NUMBER
AMPS CIRCUIT
File No. E91049
Certified File No. LR14667
Wire Range
30 Amp Regular Stranding Max #10
60 Amp Regular Stranding Max #4
VERSAMATE®SERIES PLUGS AND RECEPTACLES
VBQ BREAKER PROTECTED INTERLOCKED RECEPTACLES
600VAC/250VDC
PR12
FEATURES-SPECIFICATIONS
VersaMate VBQ Receptacles use VersaMate
Style II plugs found on 30, 60 and 100 amp pages
and are compatible with appropriately configured
Crouse-Hinds®Arktite®or Appleton®Powertite®
plugs (when installed in accordance with instruc-
tions furnished with device).
Arktite®is a registered trademark of Crouse-Hinds®.
Powertite®is a registered trademark of Appleton®.
Receptacle:
N4X with receptacle lid turned shut or
with plug locking ring tightened
Plug held in place when switch is
“Off” for convenience. Pull button
operated release mechanism. Plug
does not have to be twisted to oper-
ate switch
Dead-front construction when recep-
tacle is off. Switch cannot be turned
“ON” without fully inserted plug. Plug
cannot be removed with switch in
“ON” position
Wire Connections do not bend when
opening and closing door – minimizes
loosening during installation
or maintenance procedures
Features
Dimensions
Enclosure:
Spacious wiring room. Meets the
latest NEC wire bending require-
ments for circuit breaker enclosures
Ductile Mounting Lugs to adjust to
uneven surfaces
Copper-free construction with 316
grade Stainless Steel External
Hardware
Quick Release Cover Bolts with Triple
Leads – only 3-1/2 turns to
disengage
Recessed Flange Notches – Allows
easier cover opening with prying
instrument without flange damage
Aluminum lacquer paint finish for cor-
rosion resistance
Visible “ON” external Breaker Handle
has provisions for locking “ON” or
“OFF” with up to three Padlocks
Internal Lock-Off provision for main-
tenance when no hazardous materi-
als are present
3
3
334
12
File No. E184637
Receptacle assembly
is field replaceable for
maintenance.
Ordering information listed
in the instruction sheets
provided with the product.
Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones I & 2, Groups IIB+H2, IIA
Class II, Div. 1 & 2, Groups F & G
Class lll
NEMA 3, 4, 4X, 7 (B,C,D), 9 (F,G)
Note: The VBQ series is B7EC enclosure
based. See page E-13 for additional
dimensional information.
c
MODIFICATIONS1
Internal Lock-Off
provision for
maintenance when
no hazardous
materials are present
VERSAMATE®SERIES PLUGS AND RECEPTACLES
VBQ BREAKER PROTECTED INTERLOCKED RECEPTACLES
600VAC/250VDC
PR13
FEATURES-SPECIFICATIONS
PR
Circuit Breaker Wire Range
Square D To 30 Amp #14-4 cu.; 35-100 Amp #14-1/0 cu.
Cutler-Hammer To 20 Amp #14-10 cu.; 30-100 Amp #14-1/0 cu.
Consult Breaker Manufacturer literature for Horsepower Ratings.
†DC ratings apply to substantially non-inductive circuits.
*Pending breaker style change.
RECEPTACLE CIRCUIT BREAKER
CATALOG NUMBER
Polarization for receptacles & plugs
Drain
Breather
Drain and Breather (CSA Groups C & D)
S37
SU10
SU11
SU3
CATALOG NUMBER DESCRIPTION
1See page PR5 and price sheet for more information on these options.
VBQ RECEPTACLES
SQUARE D SQUARE D CUTLER-HAMMER CUTLER-HAMMER VERSAMATE
FAL (480 VAC MAX.) FHL (600 VAC MAX.) EHD (480 VAC MAX.) FD (600 VAC MAX.) PLUG
20 VBQ3023SN20 VBQ3023SH20 VBQ3023CN20 VBQ3023CH20 VP3385
30 VBQ3023SN30 VBQ3023SH30 VBQ3023CN30 VBQ3023CH30 VP3385
2W3P 40 VBQ3023SN40 VBQ3023SH40 VBQ3023CN40 VBQ3023CH40 VP3385
30 50 VBQ3023SN50 VBQ3023SH50 VBQ3023CN50 VBQ3023CH50 VP3385
20 VBQ3034SN20 VBQ3034SH20 VBQ3034CN20 VBQ3034CH20 VP3485
30 VBQ3034SN30 VBQ3034SH30 VBQ3034CN30 VBQ3034CH30 VP3485
3W4P 40 VBQ3034SN40 VBQ3034SH40 VBQ3034CN40 VBQ3034CH40 VP3485
50 VBQ3034SN50 VBQ3034SH50 VBQ3034CN50 VBQ3034CH50 VP3485
50 VBQ6023SN50 VBQ6023SH50 VBQ6023CN50 VBQ6023CH50 VP6385
60 VBQ6023SN60 VBQ6023SH60 VBQ6023CN60 VBQ6023CH60 VP6385
2W3P 70 VBQ6023SN70 VBQ6023SH70 VBQ6023CN70 VBQ6023CH70 VP6385
90 VBQ6023SN90 VBQ6023SH90 VBQ6023CN90 VBQ6023CH90 VP6385
100 VBQ6023SN100 VBQ6023SH100 VBQ6023CN100 VBQ6023CH100 VP6385
60
50 VBQ6034SN50 VBQ6034SH50 VBQ6034CN50 VBQ6034CH50 VP6485
60 VBQ6034SN60 VBQ6034SH60 VBQ6034CN60 VBQ6034CH60 VP6485
3W4P 70 VBQ6034SN70 VBQ6034SH70 VBQ6034CN70 VBQ6034CH70 VP6485
90 VBQ6034SN90 VBQ6034SH90 VBQ6034CN90 VBQ6034CH90 VP6485
100 VBQ6034SN100 VBQ6034SH100 VBQ6034CN100 VBQ6034CH100 VP6485
50 VBQ1023SN50 VBQ1023SH50 VBQ1023CN50 VBQ1023CH50 VP10387
70 VBQ1023SN70 VBQ1023SH70 VBQ1023CN70 VBQ1023CH70 VP10387
2W3P 90 VBQ1023SN90 VBQ1023SH90 VBQ1023CN90 VBQ1023CH90 VP10387
100 VBQ1023SN100 VBQ1023SH100 VBQ1023CN100 VBQ1023CH100 VP10387
100
50 VBQ1034SN50 VBQ1034SH50 VBQ1034CN50 VBQ1034CH50 VP10487
70 VBQ1034SN70 VBQ1034SH70 VBQ1034CN70 VBQ1034CH70 VP10487
3W4P 90 VBQ1034SN90 VBQ1034SH90 VBQ1034CN90 VBQ1034CH90 VP10487
100 VBQ1034SN100 VBQ1034SH100 VBQ1034CN100 VBQ1034CH100 VP10487
cFile No. E184637
Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones I & 2, IIB+H2, IIA
Class II, Div. 1 & 2, Groups F & G
Class lll
NEMA 3, 4, 4X, 7 (B,C,D), 9 (F,G)
Circuit Breaker 208/240 480 VAC 600 VAC 250 VDC†
Interrupting Ratings VAC
Square D FAL(HDL*) 25,000 18,000 —— 10,000
Square D FHL(HGL*) 65,000 25,000 18,000 10,000
Cutler-Hammer EHD 18,000 14,000 —— 10,000
Cutler-Hammer FD 65,000 25,000 18,000 10,000
VERSAMATE®SERIES PLUGS AND RECEPTACLES
VSI NON-METALLIC PLUGS AND SWITCHED RECEPTACLES
PR14
FEATURES-SPECIFICATIONS
Class I, Div. 2, Groups A,B,C,D
Class I, Zones 1 & 2, Groups llC, llB, llA
AEx de IIC T6
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3, 4, 4X, IP66
FM
APPROVED
Certified - File LR240743
See files for details or call Killark
File 3014299
CATALOG NUMBER
2 Pole
3 Wire
3 Pole
4 Wire
4 Pole
5 Wire
Applications
For use in hazardous and corrosive
environments such as refineries,
chemical plants, water treatment and
bio gas plants, and wherever a com-
bustible gas-air mixture or com-
bustible dust may occur
Features
Color coding and pin configuration
makes it physically impossible to
mate plugs and receptacles of
different voltages and current ratings
Interlocked switch mechanism
prevents accidental removal of plug
from receptacle under load
Horsepower rated disconnect switch
Dust caps* included with 20A and
30A plugs as standard
No seal required within Class I, Division
2 applications.
Provision for up to two optional auxilliary
contact blocks, useful for signaling cir-
cuits or starter coils.3
Dimensional information - page PR16.
VSI SERIES PLUGS & SWITCHED RECEPTACLES
TECHNICAL DATA
AC VOLTAGE AND
COLOR CODE
125 Yellow
250 Blue
480 Red
3 Ø 250 Blue
3 Ø 480 Red
3 Ø 600 Black
3 ØY 120/208 Blue
3 ØY 277/480 Red
3 ØY 347/600 Black
DESCRIPTION
RECEPTACLE
VSI20R304
VSI20R306
VSI20R307
VSI20R409
VSI20R407
VSI20R405
VSI20R509
VSI20R507
VSI20R505
PLUG
VSI20P304
VSI20P306
VSI20P307
VSI20P409
VSI20P407
VSI20P405
VSI20P509
VSI20P507
VSI20P505
PLUG
VSI30P409
VSI30P407
VSI30P405
VSI30P509
VSI30P507
VSI30P505
RECEPTACLE
VSI30R409
VSI30R407
VSI30R405
VSI30R509
VSI30R507
VSI30R505
30 AMP2
20 AMP1
PARTS AND ACCESSORIES3
Auxiliary Contact Block NC, A6004
Auxiliary Contact Block NO, A6004
PART NUMBER
VSIAUXNC
VSIAUXNO
410A rating for one auxiliary block; 5A if two are
used. Position noted (NC or NO) is when main
switch is off.
Snap into side(s) of terminal block
RECEPTACLE
ENCLOSURE MATERIAL
AMBIENT TEMPERATURE,Ta
TERMINAL CAPACITY
SWITCH RATING (HORSEPOWER)
120 VAC
240 VAC
480 VAC
600 VAC
LINE SUPPLY FUSE
BOTTOM ENTRY
POLYAMIDE
-30°C (-22°F) TO +55°C (131°F)
2 wires, rated 75°C (Ta<45°C) or 90°C (Ta>45°C)
CLASS J - size per NEC/CEC requirement
20 AMP
16-10 AWG
3/4” NPT
30 AMP
14-8 AWG
3-phase
10 HP
20 HP
25 HP
1” NPT
1-phase
1.5 HP
3 HP
5 HP
3-phase
5 HP
10 HP
15 HP
TECHNICAL DATA
PLUG
ENCLOSURE MATERIAL
TERMINAL CAPACITY
CORD OUTER DIA.
POLYAMIDE
1 wire, rated 75°C (Ta<45°C) or 90°C (Ta>45°C)
20 AMP
16-10 AWG
0.3” - 0.8”
30 AMP
14-8 AWG
0.6” - 1.1”
1VSI 20A devices are compatible with prior 16A models. However, the rating of the loweramperage will apply.
2VSI 30A devices are compatible with prior 32A models. Ratings of the lower amperagewill apply.
*Dust caps shall be installed on plugs with receptacle cover closed when the plug is not engaged in the receptacle.
VERSAMATE®SERIES PLUGS AND RECEPTACLES
VSI NON-METALLIC PLUGS AND SWITCHED RECEPTACLES PR15
PR
FEATURES-SPECIFICATIONS
Class I, Div. 2, Groups A,B,C,D
Class I, Zones 1 & 2, Groups llC, llB, llA
AEx de IIC T6
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3, 4, 4X, IP66
FM
APPROVED
Dust cap shall be installed on the plug when
the plug is not engaged in the receptacle.
PLUG DUST CAP
FOR PLUG TYPE CATALOG NUMBER
VSI63P4__ VSI63801140
VSI63P5__ VSI63801140
VSI125P4__ VSI125801140
VSI125P5__ VSI125801140
CATALOG NUMBER
63 AMP 125 AMP
3 Pole
4 Wire
4 Pole
5 Wire
VSI SERIES PLUGS & SWITCHED RECEPTACLES
AC VOLTAGE AND
COLOR CODE
3 Ø 250 Blue
3 Ø 480 Red
3 Ø 600 Black
3 ØY 120/208 Blue
3 ØY 277/480 Red
3 ØY 347/600 Black
DESCRIPTION
PLUG
VSI63P409
VSI63P407
VSI63P405
VSI63P509
VSI63P507
VSI63P505
RECEPTACLE
VSI63R409
VSI63R407
VSI63R405
VSI63R509
VSI63R507
VSI63R505
PLUG
VSI125P409
VSI125P407
VSI125P405
VSI125P509
VSI125P507
VSI125P505
RECEPTACLE
VSI125R409
VSI125R407
VSI125R405
VSI125R509
VSI125R507
VSI125R505
Applications
For use in hazardous and corrosive
environments such as refineries,
chemical plants, water treatment and
bio gas plants, and wherever a com-
bustible gas-air mixture or com-
bustible dust may occur
When VSI Series is installed in Class
II Div. 1 & 2 locations, dust caps for
plugs are required. See ordering
information below
Features
Color coding and pin configuration
makes it physically impossible to
mate plugs and receptacles of
different voltages and current ratings
No seals required within Class I, Div.
2 applications
Interlocked switch mechanism
prevents accidental removal of plug
from receptacle under load
Horsepower rated disconnect switch
includes 1 auxiliary contact (late
make, early break) for signaling cir-
cuits.
63A, 125A models
Dimensional Information
See page PR16
VSI non-metallic devices NOT intermateable with Versamate® NEC metallic series.
TECHNICAL DATA
RECEPTACLE
ENCLOSURE MATERIAL
AMBIENT TEMPERATURE,Ta
TERMINAL CAPACITY
SWITCH RATING (HORSEPOWER)
120 VAC
240 VAC
480 VAC
600 VAC
LINE SUPPLY FUSE
BOTTOM ENTRY
FIBER REINFORCED POLYESTER
-20°C (-4°F) TO +40°C (104°F)
2 wires, 90°C rated
CLASS J - size per NEC/CEC requirement
63 AMP
6-1/0 AWG
3-phase
10 HP
20 HP
40 HP
60 HP
1-1/2” NPT
125 AMP
1/0-3/0 AWG
3-phase
20 HP
40 HP
100 HP
125 HP
2” NPT
TECHNICAL DATA
PLUG
ENCLOSURE MATERIAL
TERMINAL CAPACITY
CORD OUTER DIA.
POLYAMIDE
1 wire, 90°C rated
63 AMP
10-4 AWG
0.94” - 1.4”
125 AMP
6-1/0 AWG
1.2” - 2
Certified - File LR240743
See files for details or call Killark
File 3014299
VSI NON-METALLIC PLUGS AND SWITCHED RECEPTACLES
PR16
13.5”(342 mm)
RECEPTACLE & PLUG 63A
3 POLE - 4 WIRE AND 4 POLE - 5 WIRE RECEPTACLE & PLUG 125A
3 POLE - 4 WIRE AND 4 POLE - 5 WIRE
.35”(9 mm)
.35”
(9 mm)
6”
(152 mm)
7.1”
(180 mm)
.51”
(13 mm)
16”
(407 mm)
8.3”
(211 mm)
19.4”(493 mm)
.43”(11 mm)
.43”
(11 mm)
8.7”
(220 mm)
10.7
(270 mm)
.8”
(20.5 mm)
21.8”
(553 mm)
12.0”
(296 mm)
4.1” (104 mm)
4.9” (125 mm) .24”
(6 mm)
(6 mm)
9.8” (248 mm)
6.25” (159 mm)
.47” (12 mm)
7.12” (181 mm)
4.0” (103 mm)
3.7” (94 mm)
4.52” (115 mm) .24”
(6 mm)
5.9” (150 mm)
.47” (12 mm)
6.6” (168 mm)
.24”
(6 mm)
3.66” (93 mm)
4.13” (105 mm)
9.13” (232 mm)
.24”
O.D. 3” (76 mm)
6.9” (176 mm)
O.D. 2.4”
(60 mm)
RECEPTACLE 20A
2 POLE - 3 WIRE
PLUG 20A RECEPTACLE 20A
3 POLE - 4 WIRE AND 4 - POLE 5 WIRE
4.9” (124 mm)
5.9” (150 mm) .24”
(6 mm)
.47” (12 mm)
8.15” (207 mm)
.24”
(6 mm)
4.8” (123 mm)
5.3” (135 mm)
11.1” (281 mm)
O.D. 3.9 (99 mm) - 4 Wire
O.D. 4” (102 mm) - 5 Wire
8.03” (204 mm)
O.D. 2.8”
(72 mm)
RECEPTACLE 30A
3 POLE - 4 WIRE AND 4 POLE - 5 WIRE PLUG 30A
Dimensions
NOTE: Drawings are not to scale
10.6
(268.5 mm)
4.4”
(112 mm)
2.7”
(69.5 mm)
3.3” (84 mm)
4.9”
(125 mm)
3.2”
(82 mm)
12.2”
(310.5 mm)
3.8” (96 mm)
4.5” (115 mm)
7.4” (188 mm)
VERSAMATE®SERIES PLUGS AND RECEPTACLES
VCR CLEAN ROOM RECEPTACLES PR17
FEATURES-SPECIFICATIONS
PR
Suitable for:
Class I, Div. 2, Groups A,B,C,D
Class I, Zones 1 & 2, Groups IIC, IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3
CENELEC-EEx de IIC T6 IP54
Applications
Designed specifically for hazardous
location clean rooms, such as found
in the pharmaceutical industry,
where equipment must be easy to
clean and free of contaminant hold-
ing cavities. Electrical devices
should also be flush wall mounted,
with concealed wiring, to minimize
contamination.
VSI20P and VSI30P series plugs
include debris caps, which are re-
quired in Class II Div.1 and 2 locations.
Features
Available with single or duplex
receptacles, in 16 or 32 amps with
a variety of voltage and pin
configurations 2
Flush mounting, smooth contours
for easy cleaning
Hazardous locations suitability
Enclosure made of stainless steel
with concealed EPDM gasketing
Cover is hinged on left side.
Provides access with loosening of 2
screws
Color coding and pin configuration is
compliant to IEC 60309-2.
Interlocked switch mechanism pre-
vents accidental removal of plug
from receptacle under load.
Explosion protected disconnect
switch requires protection by Class
“J” fuse (upstream), 20A max. for
16A receptatcle, 40A max. for 32A
receptacle.
CATALOG NUMBER
2 Pole
3 Wire
3 Pole
4 Wire
4 Pole
5 Wire
VCR SERIES CLEANROOM RECEPTACLES
AC VO LTAGE AND
COLOR CODE
125 Yellow
250 Blue
480 Red
3 Ø 250 Blue
3 Ø 480 Red
3 Ø 600 Black
3 ØY 120/208 Blue
3 ØY 277/480 Red
3 ØY 347/600 Black
DESCRIPTION
II 2G EEx ed IIC T5/T6, IP65
PTB No. 01 ATEX 1001
VCR32R409
VCR32R407
VCR32R405
VCR32R509
VCR32R507
VCR32R505
OFF
ON
14.17" (360)
15.75" (400)
16.54" (420)
6.88" (177)
8.44" (217)
9.31" (237)
VSI20P304
VSI20P306
VSI20P307
VSI20P409
VSI20P407
VSI20P405
VSI20P509
VSI20P507
VSI20P505
VCR16R304
VCR16R306
VCR16R307
VCR16R409
VCR16R407
VCR16R405
VCR16R509
VCR16R507
VCR16R505
VSI30P409
VSI30P407
VSI30P405
VSI30P509
VSI30P507
VSI30P505
32 AMP1
16 AMP1
RECEPTACLE PLUG2RECEPTACLE PLUG2
1VCR catalog numbers shown in table are for SINGLE receptacles. For duplex units, add second
receptacle configuration to catalog number.
Example: VCR32R409-16R304
Left Receptacle Position
Right
Receptacle Position
Single/Duplex
Receptacle
Profile
Single
Receptacle
Duplex
Receptacle
Duplex Receptacle
220A plugs fit 16A receptacles; 30A plugs fit 32A receptacles.
VCR non-metallic plugs NOT intermateable with VersaMate®NEC metallic series.
KR SERIES PLUGS AND RECEPTACLES
HAZARDOUS LOCATION - DELAYED ACTION
PR18
FEATURES-SPECIFICATIONS
Listed E23572
Certified LR146671
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, llB,llA
NEMA 7 (C,D)
ELECTRICAL RATINGS
Applications
KR Series plugs and receptacles are
suitable:
In hazardous locations due to the
presence of flammable vapors or
gases
Where a heavy duty plug and recep-
tacle is necessary
Where a connection is required for
portable or movable equipment such
as tools, motors, hand lights, etc.
KP series plugs use solder termina-
tions for sure connection
KR series receptacles use wire leads
for termination
Features
Factory sealed receptacles
Copper free aluminum
Straight or angle type receptacles
Delayed action contacts (See Time
Delay Inset)
Plugs with a wide range of grommet
openings
Extra long grounding pole makes
contact first and breaks contact last
Heavy duty construction to withstand
rough and constant usage
Selection
Refer to page headings for suitability of
specific items. When selecting a Killark
device consider the following:
(A) Installation area (Hazardous or
Weather-Resistant)
(B) Amperage
(C) Voltage
(D) Electrical Rating (see below)
(E) Grounding
(G) Modifications (see right)
(H) Mounting arrangement
(I) Box and hub type
(J) Cord diameter
Details of Safety
Time Delay Feature
The key slot provided in the receptacle
engages the key of the plug permitting
entrance of the plug in the receptacle
in only one position. See steps 1-4.
The contacts are enclosed in long
accurate insulating cavities. It is in
these cavities that the arcs are extin-
guished. All contacts are made through
round tellurium copper tubing which is
extra heavy to withstand arcing as
required on the various ampere ratings.
Both plugs and receptacles are
equipped with an extra long grounding
pole which establishes grounding
before the power contacts are
engaged. These grounding poles are
also the last to break contact. This
assures bonding of the portable device
to the electrical conduit system.
Selection
Modifications are available by adding
the following suffix to the catalog num-
ber. (Note: It must be added to both
the plug and the receptacle so they
will mate.)
TYPE AMPERAGE VOLTAGE VAC CIRCUIT H.P. HERTZ
120 AMP 20 115/230 2W3P 1 60
7 460 2W3P 1/2 60
7 460 3W4P 1 60
30 AMP 30 115/230 2W3P 1-1/2 60
30 115/230 3W4P 3 60
30 460 2W3P 3 60
30 460 3W4P 5 60
60 AMP 60 115/230 2W3P 5 60
60 115/230 3W4P 5 60
Safety Time Delay Feature
MODIFICATIONS
Interior contact assem-
blies are to be rotated 22-
1/2° to the right.
SU37
Interior contact assem-
blies are to be rotated
22-1/2° to the left.
SU38
CATALOG NUMBER DESCRIPTION
Plug then can be moved
completely in and be energized
Receptacle Keyway
Key Plug
Plug can move in only to the
first step of the keyway until...
Align Keyway on plug with receptacle.
1
2
3
4
...key is moved up
1CSA approval on 20 Amp only.
KR SERIES PLUGS AND RECEPTACLES
20 AMP/115/230 V.A.C. • 1Ø 2 WIRE, 3 POLE PR19
FEATURES-SPECIFICATIONS
PR
KRJ RECEPTACLE WITH AJ OR JL BOX
KRS 20A 1Ø 2W RECEPTACLE WITH SWB BOX2
ELECTRICAL RATING
Listed File No. E23572
Certified File No. LR14667
CIRCUIT RATING (60 HERTZ)
1Ø 20 AMPS 115/230 V.A.C. 1 H.P.
2W3P
CATALOG NUMBER
KRS Series KRA
CATALOG NUMBER
AJC JLC JLX
KRJC-120 KRJX-120
KRAJC-220 KRJC-220 KRJX-220
KRAJC-320 ——
HUB
SIZE
1/2"
3/4"
1"
HUB
SIZE
1/2"
3/4"
1"
KP 20 AMP PLUG
CATALOG NO. DESCRIPTION
Plug furnished with
KP-20ABC 3 grommets range .250 - .625
KRS-Series
BACK BOX ONLY
1/2" JLC-1 JLX-1
3/4" AJC-2 JLC-2 JLX-2
1" AJC-3 ——
RECEPTACLE ONLY - CATALOG NUMBER KRJ-20
JL Series boxes shown on page F60. Refer to page headings for suitability of
specific items.
See page PR18 for available polarization options.
Plug
RECEPTACLE ONLY - CATALOG NUMBER KRS-20
1KRS Series receptacles - Class I, Group D.
2SWB Series mounting splice boxes only for receptacles shown above listed on page C19.
See page PR18 for available polarization options.
AJC JLXJLC
KRJ-Series
See page PR18 for available polarization
options.
SINGLE
RECEPTACLE &
DEAD END BOX
BOX
ONLY
SINGLE
RECEPTACLE &
FEED-THRU BOX
BOX
ONLY
KRS-215-120
KRS-215-220
KRS-215-320
SWB-1
SWB-2
SWB-3
SWB-4
SWB-5
SWB-6
KRS-218-120
KRS-218-220
KRS-218-320
DOUBLE
RECEPTACLE &
DEAD END BOX
BOX
ONLY
DOUBLE
RECEPTACLE &
FEED-THRU BOX
2KRS-215-120
2KRS-215-220
2KRS-215-320
SWB-7
SWB-8
SWB-9
BOX
ONLY
SWB-10
SWB-11
SWB-12
2KRS-218-120
2KRS-218-220
2KRS-218-320
Class I, Div. 1 & 2, Groups C,D1
Class l, Zones 1 & 2, llB,llA
NEMA 7 (C,D)
KR SERIES PLUGS AND RECEPTACLES
30 AMP 115/230 V.A.C. 7 AMP 460 V.A.C.
PR20
FEATURES-SPECIFICATIONS
Class I, Div. 1 & 2, Groups C,D1
Class I, Zones 1 & 2, llB, llA
NEMA 7 (C,D)
Listed - File E23572
See files for details or call Killark.
KRS/KRJ SERIES PLUG
KRA SeriesKRS Series Plug
KRJ RECEPTACLE WITH AJ OR JL BOX
KP 30 AMP PLUG
CATALOG NUMBER
1Ø, 2-WIRE, 3Ø, 3-WIRE PLUG GROMMET
3-POLE 4-POLE TYPE RANGE
KP-303D23 KP-304D23 D .375-.625
KP-303D45 KP-304D45 D .625-.875
KP-303E45 KP-304E45 E .875-1.125
KP-303E67 KP-304E67 E 1.125-1.375
ELECTRICAL RATING
CIRCUIT RATING (60 HERTZ)
7 Amps 460 V.A.C. 1¼2 H.P.
– OR –
30 Amps 115/230 V.A.C. 1-1¼2 H.P.
7 Amps 460 V.A.C. 1 H.P.
– OR –
30 Amps 115/230 V.A.C. 3 H.P.
HUB CATALOG NUMBER
SIZE AJC JLC JLX
1/2" KRJC-1303 KRJX-1303
3/4" KRAJC-2303 KRJC-2303 KRJX-2303
1" KRAJC-3303 ——
1/2" KRJC-1304 KRJX-1304
3/4" KRAJC-2304 KRJC-2304 KRJX-2304
1" KRAJC-3304 ——
1/2" JLC-1 JLX-1
3/4" AJC-2 JLC-2 JLX-2
1" AJC-3 ——
1Ø
2-Wire
3-Pole
3Ø
3-Wire
4-Pole
Back
Box
Only
KRS RECEPTACLE WITH SWB BOX2
1 Ø
2-Wire
3-Pole
3 Ø
3-Wire
4-Pole
D Type
CIRCUIT
JL Series boxes shown on page F60. Refer to page headings for suitability of specific items.
See page PR18 for available polarization options.
RECEPTACLE
ONLY
AJC JLXJLC
KRS-Series
E Type
KRJ-Series
RECEPTACLE ONLY- CATALOG NUMBER KRJ-303
RECEPTACLE ONLY- CATALOG NUMBER KRJ-304
See page PR18 for available
polarization options.
1Ø, 2-WIRE,
3-POLE
DEAD END BOX
BOX
ONLY
1Ø, 2-WIRE,
3-POLE
FEED THRU BOX
BOX
ONLY
KRS-215-1303
KRS-215-2303
KRS-215-3303
SWB-1
SWB-2
SWB-3
SWB-4
SWB-5
SWB-6
KRS-218-1303
KRS-218-2303
KRS-218-3303
3Ø, 3-WIRE,
4-POLE
DEAD END BOX
BOX
ONLY
3Ø, 3-WIRE,
4-POLE
FEED THRU BOX
BOX
ONLY
KRS-215-1304
KRS-215-2304
KRS-215-3304
SWB-1
SWB-2
SWB-3
SWB-4
SWB-5
SWB-6
KRS-218-1304
KRS-218-2304
KRS-218-3304
CATALOG NUMBER - SINGLE GANG ONLY
KRS-303 KRS-304
1KRS Series receptacles - Class I, Group D.
2SWB Series mounting splice boxes for receptacles shown above listed on page C19.
Two gang models not available.
See page PR18 for available polarization options.
HUB
SIZE
1/2"
3/4"
1"
KR SERIES PLUGS AND RECEPTACLES
60 AMP/115/230 V.A.C. • 30 AMP/460 V.A.C. PR21
FEATURES-SPECIFICATIONS
PR
Listed File No. E23572
KRJ Series KRA Series Plug
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, llB,llA
NEMA 7 (C,D)
KR RECEPTACLE ASSEMBLIES
JAL TYPE MOUNTING BOXES
CATALOG NUMBER
1Ø, 2-WIRE 3Ø, 3-WIRE SPLICE
3-POLE 4-POLE BOX ONLY
KRJX-3603 KRJX-3604 JALX-3
KRJX-4603 KRJX-4604 JALX-4
—— —
KRAJAC-4603 KRAJAC-4604 AJAC-4
KRAJAC-5603 KRAJAC-5604 AJAC-5
KRAJAC-6603 KRAJAC-6604 AJAC-6
KRAJAT-4603 KRAJAT-4604 AJAT-4
KRAJAT-5603 KRAJAT-5604 AJAT-5
KRJ-603 KRJ-604
HUB
SIZE
1"
1-1/4"
1-1/4"
1-1/2"
2"
1-1/4"
1-1/2"
HUB
STYLE
“X”-3 Close-up
Plugs Supplied
Feed Thru
Top and
Bottom
T Sides and Top
JAL Series
Boxes
AJA Series
Boxes
KP Type Plugs
KRJ-60 Type Receptacles
JAL Type
HUB ABCDEH
1" 2-3/8" 1-5/32" 4-5/8" 5-1/4" 4-1/8" 5/16"
1-1/4" 3-1/8" 1-17/32" 4-5/8" 5-1/4" 4-1/8" 5/16"
Dimensions-Back Boxes
AJAC Types
AJAT Type
KR 60 AMP PLUGS
CATALOG NUMBER
1Ø, 2-WIRE, 3Ø, 3-WIRE GROMMET
3-POLE 4-POLE RANGE
KP-603D345 KP-604D345 .500-.875
KP-603E45 KP-604E45 .875-1.125
KP-603E67 KP-604E67 1.125-1.375
KP-604F34 1.250-1.500
KP-604F56 1.500-1.750
ELECTRICAL RATING
CIRCUIT RATING (60 HERTZ)
30 Amps 460 V.A.C. 3 H.P.
– OR –
60 Amps 115/230 V.A.C. 3 H.P.
30 Amps 460 V.A.C. 5 H.P.
– OR –
60 Amps 115/230 V.A.C. 5 H.P.
1 Ø
2-Wire
3-Pole
3 Ø
3-Wire
4-Pole
RECEPTACLE ONLY
BOX
STYLE
NOTE: For dead end box, use AJAC Series and CUP Series close-up plug.
39/16"
(90)
5"
(127)
715/16"
(202)
71/2"
(191)
45/8"
(117)
47/8"
(124)
See page PR18 for available polarization options.
See page PR18 for available polarization
options.
ACCEPTOR®SERIES PLUGS AND RECEPTACLES
UGR/UGP INTERCHANGEABLE BLADE STYLE
PR22
FEATURES-SPECIFICATIONS
The ACCEPTOR®UGP/UGR Plug and
Receptacle system, with its unique,
patented design, is interchangeable1
with other NEMA bladed type explo-
sion-proof and dust ignition proof
devices. The series has been tested
and classified for use with Crouse-
Hinds®Ark-Gard®2 and Appleton®U-
Line®plugs and receptacles in haz-
ardous locations. Now available in
GFCI version. See page PR26.
How The Acceptor System Works
ACCEPTOR receptacles contain an
integral switch which must be closed to
energize the circuit. The design
permits only an approved plug to be
energized. To actuate the switch, the
plug must be inserted and rotated
clockwise approximately 45o. The plug
will lock into this position preventing
accidental disengagement. To remove,
simply push in then turn the plug coun-
terclockwise and pull straight out.
Plugs and receptacles may be used
where interchangeable bladed devices
are needed in locations made haz-
ardous by the presence of flammable
gases or vapors, combustible dusts or
easily ignitable fibers and flyings.
Plug can serve to provide power
for portable equipment used in both
hazardous and non-hazardous areas.
Applications
Petroleum Refineries
Chemical Plants
Wet/Damp Areas
Corrosive Environments
Petroleum Plants
Grain Elevators/Feed Mills
Flour and Feed Mills
Indoor or Outdoor Locations
Features
All external hardware is 316 stainless steel
to provide low maintenance and long life
Factory sealed chamber in UGR recepta-
cle contains switch's arcing components
No additional external seals are required,
except in Group B
applications
Quick Wiring Plug
Single piece shell for fewer parts
Transparent wiring entrance holes for easy
conductor insertion
Screws tighten from side with “full sized
screwdriver
Class I, Div. 1 & 2, Groups B1,C,D
Class I, Zones 1 & 2, Groups IIB+H2, IIA
Class II, Div. 1 & 2, Groups F,G
Class III
NEMA 3, 7 (B,C,D), 9 (F,G)
Listed File No. E91049 and/or E53660
Certified File No. LR14667
Receptacles are U.L. Listed as
raintight. Proper sealing against
moisture is assured
Spring loaded receptacle cover clos-
es when plug is removed to provide
protection when not in use
Copper-free aluminum (less than
4/10 of 1%) alloy resists corrosion
Electrostatically applied and baked
powder epoxy/polyester finish
PLUG
Plug
ACCEPTOR®plugs conform to NEMA
configurations and can be used with
standard receptacles in non-hazardous
areas to maximize equipment utilization.
The system's “turn to engage” feature
1.51"1.69"
2.55"
2Plugs Rated Group B when used with properly rated &
installed receptacles. See next page.
Plugs with mesh grips (page PR26) are shipped as component
plug and grip.
1Exact models classified for interchangeability are
listed in the information sheet provided with the
products. Ark-Gard®is a registered trademark of
Crouse-Hinds®. U-Line®is a registered trademark
of Appleton Electric Company®.
UGMG
UGP-15231 UGP-15231QW
UGP-15232 UGP-15232QW
NEMA
CONFIGURATION
5-15P
6
G
W
6-15P
G
W
G
G
6-20P
G
W
5-20P
6
G
W
locks in plug and can be used to pre-
vent accidental disengagement of criti-
cal equipment.
Plugs for use with type S, SO, ST or
STO heavy duty cord.
15 AMP PLUG
W/QUICK WIRING
15 AMP
PLUG
CATALOG NUMBER
20 AMP PLUG
W/QUICK WIRING
20 AMP
PLUG
CATALOG NUMBER
UGP-20231 UGP-20231QW
UGP-20232 UGP-20232QW
NEMA
CONFIGURATION
VOLTAGE
125VAC
250VAC
NEW!
QW
Quick Wiring Plug
RECEPTACLES AND ASSEMBLIES4
ACCEPTOR®SERIES PLUGS AND RECEPTACLES
UGR INTERCHANGEABLE BLADE STYLE PR23
PR
1/2"
3/4"
1"
1/2”
3/4"
1"
1/2"
3/4"
1"
1/2”
3/4"
1"
HUB
SIZE
RECEPTACLE ONLY
DEAD END
FEED-THRU
RECEPTACLE ONLY
DEAD END
FEED-THRU
ENCLOSURE
STYLE
NEMA RATING
& CONFIGURATION
1Items in this column are suitable for Class I, Group B in addition to Class I, Groups C, D.
Also suitable for Class I, Zone 1, Groups IIB+H2, IIA.
2Seals must be installed within 6 inches of conduit opening.
3Items in this column may also be used in Class I, Zone 1, Groups IIB, IIA.
Assembly numbers not rated for Group B are shipped as receptacle & back box components.
4Refer to page C19 for additional SWB Series Back Box configurations.
5Canada only configuration
6Canadian Codes now allow “T” combination slots for 15A or 20A plugs. Check breaker and wire feed size for proper application ratings.
NOTE: For replacement receptacle cover and hinge, order KIT-173.
2 POLE
3 WIRE
2 POLE
3 WIRE
1/2"
3/4"
1"
1/2”
3/4"
1"
RECEPTACLE ONLY
DEAD END
FEED-THRU
2 POLE
3 WIRE
1/2"
3/4"
1"
1/2”
3/4"
1"
RECEPTACLE ONLY
DEAD END
FEED-THRU
2 POLE
3 WIRE
20 Amp
125 Volt
20 Amp
250 Volt
15 Amp
250 Volt
15 Amp
125 Volt
5-20R
5-15R
6-15R
6-20R
UGRO-20231
UGR7-20231
UGR8-20231
UGR9-20231
UGR10-20231
UGR11-20231
UGR12-20231
UGROC-15231
UGR7C-15231
UGR8C-15231
UGR9C-15231
UGR10C-15231
UGR11C-15231
UGR12C-15231
UGRO-20232
UGR7-20232
UGR8-20232
UGR9-20232
UGR10-20232
UGR11-20232
UGR12-20232
UGROC-15232
UGR7C-15232
UGR8C-15232
UGR9C-15232
UGR10C-15232
UGR11C-15232
UGR12C-15232
UGRO-20231
UGR1-20231
UGR2-20231
UGR3-20231
UGR4-20231
UGR5-20231
UGR6-20231
UGROC-15231
UGR1C-15231
UGR2C-15231
UGR3C-15231
UGR4C-15231
UGR5C-15231
UGR6C-15231
UGRO-20232
UGR1-20232
UGR2-20232
UGR3-20232
UGR4-20232
UGR5-20232
UGR6-20232
UGROC-15232
UGR1C-15232
UGR2C-15232
UGR3C-15232
UGR4C-15232
UGR5C-15232
UGR6C-15232
UGRB1-20231
UGRB2-20231
UGRB3-20231
UGRB4-20231
UGRB5-20231
UGRB6-20231
UGRB1C-15231
UGRB2C-15231
UGRB3C-15231
UGRB4C-15231
UGRB5C-15231
UGRB6C-15231
UGRB1-20232
UGRB2-20232
UGRB3-20232
UGRB4-20232
UGRB5-20232
UGRB6-20232
UGRB1C-15232
UGRB2C-15232
UGRB3C-15232
UGRB4C-15232
UGRB5C-15232
UGRB6C-15232
SINGLE GANG12
GROUPS B,C,D,F&G
SINGLE GANG34
GROUPS C, D, F, & G
DOUBLE GANG34
GRO UPS C D, F, & G
SWB-1, 2, 3 SWB-4, 5, 6 Single Gang Double Gang
5
6
5
6
PR24
NEMA CONFIGURATION CATALOG NUMBER WEATHER RATING
125V CONNECTOR CAP STYLE
250V CONNECTOR CAP STYLE
20 Amp
125 Volt
2
POLE
20 Amp
250 Volt
2 POLE
3 WIRE
6-20R with T-slots
Breech-Lock with Notch
Flip Type
5-20R with T-slots
Breech-Lock with Notch
Flip Type
Killark 250V Plugs
20 Amp
15 Amp
Killark 125V Plugs
20 Amp
15 Amp
UGRC-20231B
UGRC-20231F
2
UGP-20231
UGP-15231
UGRC-20232B
UGRC-20232F
2
UGP-20232
UGP-15232
N4X*
N3**
N4X*
N3**
ACCEPTOR®SERIES PLUGS AND RECEPTACLES
UGRC CONNECTORS
FEATURES-SPECIFICATIONS
Connector with Breech-Lock Cap “3rd Hand” Plug Operation
Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones 1 & 2, Groups IIB+H2, IIA
Class II, Div. 1 & 2, Groups F,G
Class III
NEMA 3, 4X*
Certified File No. LR14667
UGRC Connector
Breech cap model shown, Flip cap model dimensions
are similar
CONNECTORS
The ACCEPTOR® UGRC Connector com-
plements UGP/UGR Plugs and
Receptacles, as well as Ground Fault
Protected UGFI and UGRGF Models.
Used with Acceptor plugs, connectors can
extend the reach for hazardous location rated
portable equipment such as hand lamps.
Connectors eliminate the need for user cre-
ated corded box mounted receptacles.
UGRC Connectors are interchangeable
and classified for use with other NEMA
bladed type explosion-proof and dust
ignition proof plugs, including Crouse-
Hinds® Ark-Gard®2 and Appleton®
ULine®.
Features
Available with the exclusive Breech-Lock
Cap (see PR3 for more info) - patented
notch provides “3rd hand” plug operation
(holds lid open while one hand operates
plug, and other holds connector).
Factory Sealed Construction
Suitable for 14 or 12 gauge SOOW or
similar cable
Copper-free aluminum (less than 4/10 of
1%) alloy resists corrosion
Electrostatically applied and baked pow-
der epoxy/polyester finish
Dead Front Construction with integral
switch - requires Hazardous Rated NEMA
Bladed plug for operation
Ark-Gard® is a registered trademark of Crouse-Hinds®
U-Line® is a registered trademark of Appleton
Electric Company®
Industrial Applications
Petroleum Refineries
Chemical/Petrochemical Plants
Oil Rigs & Platforms
Wet/Corrosive Environments
Grain Elevators
Dimensions
1
Connector shown with Acceptor UGRP receptacle mounted
in explosion proof Quantum® enclosure
8.25
2.88
3.69
*Breech cap models N4X with lid closed and turned, N3 When Plug inserted Hinge Up
**Flip Lid models N3 with hinge in UP position with or without plug
Replacement Cap and Hinge Kits: Breech KIT-173B, Flip KIT-173
1CSA certified for Cananda and/or other jurisditions accepting CSA.
2Add QW to catalog number for Quick Wiring type plug.
Flip Cap
UGP Plug
PR25
PR
FEATURES-SPECIFICATIONS
ACCEPTOR®S E R I E S PLUGS AND RECEPTACLES
UGRP PANEL MOUNT RECEPTACLES
* UGRP Receptacles are available
“Factory Installed” in the following series:
Enclosures
- Series EXB, B7E
Distribution Equipment
-Series D2L, B7L Lighting Panelboards
* Contact factory for ordering information
Class I, Div. 1 & 2, Groups B,C,D1
Class I, Zones 1 & 2, Groups IIB+H2, IIA
Class II, Div. 1 & 2, Groups F,G
Class III
NEMA 3, 4X*
Certified File No. LR146672
C US
Typical InstallationBreech Cap Model
Typical CLI Div. I
application
Typical CLI Div. 2
application
Breech Caps
Flip Lids
NEMA CONFIGURATION CATALOG NUMBER WEATHER RATING
125V PANEL RECEPTACLE CAP STYLE
250V PANEL RECEPTACLE CAP STYLE
20 Amp
125 Volt
2 POLE
3 WIRE
6-20R with T-slots
Breech-Lock with Notch
Flip Type
5-20R with T-slots
Breech-Lock with Notch
Flip Type
Killark 250V Plugs***
20 Amp
15 Amp
Killark 125V Plugs***
20 Amp
15 Amp
UGRP-20231B
UGRP-20231F
3
UGP-20231
UGP-15231
UGRP-20232B
UGRP-20232F
3
UGP-20232
UGP-15232
N4X*
N3**
N4X*
N3**
*Breech cap models N4X with lid closed and turned, N3 When Plug inserted Hinge Up
**Flip Lid models N3 with hinge in UP position with or without plug
***See PR24 for Plug NEMA Diagram and Dimensions
Replacement Cap and Hinge Kits: Breech KIT-173B, Flip KIT-173
1Class I Div. I B,C,D in enclosures certified to 325 explosive PSI. Class I Div. 2 in standard location enclo-
sures using only non-arcing components.
2cCSAus Certified for United States, Canada, and other jurisdictions accepting the mark.
3Add QW to catalog number for Quick Wiring type plug.
20 Amp
250 Volt
2 POLE
3 WIRE
Flip Cap
Breech Cap model shown.
Flip Cap model dimensions are similar
PANEL RECEPTACLES
The ACCEPTOR® UGRP Panel
Receptacle complements UGP/UGR Plugs
and Receptacles, as well as Ground Fault
Protected UGFI and UGRGF Models.
Used with Acceptor plugs, panel recepta-
cles provide local power for hazardous loca-
tion rated portable equipment such as hand
lamps. Units are suitable for Class I Div. 1
or Class I Div.2 depending on the enclo-
sure type used1.
UGRP Panel Receptacles are inter-
changeable and classified for use with
other NEMA bladed type explosion-proof
and dust ignition proof plugs, including
Crouse-Hinds® Ark-Gard®2 and
Appleton® ULine®.
Features
Available with the exclusive Breech-Lock
Cap (see PR3 for more info) - patented
notch provides “3rd hand” plug opera-
tion (holds lid open while one hand
operates plug, and other holds connector).
Factory Sealed Construction
Copper-free aluminum (less than 4/10 of
1%) alloy resists corrosion
Electrostatically applied and baked
powder epoxy/polyester finish
Dead Front Construction with integral
switch - requires Hazardous Rated
NEMA Bladed plug for operation
Ark-Gard® is a registered trademark of Crouse-Hinds®
U-Line® is a registered trademark of Appleton
Electric Company®
Industrial Applications
Petroleum Refineries
Chemical/Petrochemical Plants
Oil Rigs & Platforms
Wet/Corrosive Environments
Grain Elevators
Dimensions
3.69
4.50
2.94
Breech Lid
XHL INCANDESCENT
ACCEPTOR®SERIES PLUGS AND RECEPTACLES
ADAPTER AND ACCESSORIES
PR26
FEATURES-SPECIFICATIONS
UGRA ADAPTER KIT
OPTIONAL STRAIN RELIEF
GRIP FOR UGP PLUGS
XHL SERIES HAND LAMPS
Stainless steel grips for cable strain
relief or bend control.
UNIVERSAL ADAPTER KIT
ACCEPTOR®receptacles are available
with an adapter kit for mounting to
Crouse-Hinds®EDS Series or Appleton®
EFD Series back boxes.
ACCEPTOR receptacles properly
installed with these adapter kits are
U.L. Listed for use in Class I, Div. 2,
Groups B,C,D hazardous locations and
Zone II, Groups IIB + H2, IIA.
Kit contains one ACCEPTOR®recepta-
cle plus adapter plate and mounting
bolts.
UGRA-20231
UGRA-20232
ADAPTER KIT
CATALOG NUMBER
NEMA RATING
& CONFIGURATION
2 POLE
3 WIRE
2 POLE
3 WIRE
Features
Test and Reset push buttons are
provided on cover assembly, with
optional pilot light available1
Unit should be tested monthly
Includes new GFCI to meet latest
UL943 GFCI standards revisions
Exterior gasket provides NEMA 3
weatherproof protection
Ground boss for grounding in the
splice box
Color coded wiring and stainless steel-
cover bolts
Receptacle used is UGRO-20231.
See page PR23
Listed File No. E97760
XHLF Fluorescent
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB,llA
Class lI, Div. 1 & 2, Groups E,F,G
XHLF26 Fluorescent hand lamp
XHLF26-50KP
Fluorescent hand lamp with
- 50' of 16/3 SOW cord and
15A Acceptor plug
5-20R
20 Amp 125 Volt
6-20R
20 Amp 250 Volt
XHL-100
XHL-GL
XHLG
XHLS
Handlamp
Replacement globe
Replacement guard
Replacement socket
CATALOG NUMBER DESCRIPTION
Listed File No. E91049
XHL Incandescent
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB,llA
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB,llA
Class lI, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3, 7(C,D) 9(E,F,G)
c
Listed File No. E97760
Certified File No. LR10019
CATALOG NUMBER DESCRIPTION
NEMA RATING &
CONFIGURATION
20A, 125V, 2P, 3W
ENCLOSURE
STYLE
Dead End
Dead End
Dead End
Feed Thru
Feed Thru
Feed Thru
UGMG Mesh grip
CATALOG NUMBER DESCRIPTION
A handy accessory to the ACCEPTOR®
Series, these hand lamps can be used
as an illumination source where flam-
mable materials are present, such as
processed finish goods, storage vats,
or handling areas.
See page L14 for detailed
information and features.
UGRA
Certified LR14667
Certified LR11714
See files for details or call Killark.
1For Red LED pilot light indicator of live
circuit, add “-PL” to catalog number.
Example - UGRGF107-PL.
UGMG
XHL XHLF UGRGF
XHLF FLUORESCENT (120VAC)
GFI PROTECTED RECEPTACLE
Utilizes FXS GFI and ACCEPTOR®
receptacle to interrupt a circuit, when a
ground fault is detected on equipment
which may be handled by personnel in
hazardous locations.
Electrical Rating
GFI units are rated at 20A, 120 VAC,
60Hz. Class A.
4-6 miliamp trip setting
Trip Time-UL Curve
HUB
SIZE
1/2”
3/4”
1”
1/2”
3/4”
1”
CATALOG1
NUMBER
UGRGF107
UGRGF108
UGRGF109
UGRGF110
UGRGF111
UGRGF112
GFCI RECEPTACLE ADAPTER (W/CORD SET)
ACCEPTOR®SERIES PLUGS AND RECEPTACLES
ADAPTER AND ACCESSORIES PR27
FEATURES-SPECIFICATIONS
PR
The GFCI protected ACCEPTOR®is the
solution to OSHA's requirements for
GFCI protection when using portable
equipment in hazardous and wet loca-
tions. For use with 120 volt 15 or 20
amp receptacles without GFCI protec-
tion, the Adapter Unit provides GFCI
and circuit protection to connected
apparatus by simply being plugged
into an existing receptacle.
The Hard-Wired Unit provides the
same protection and is used directly
as a GFCI protected device. Units are
feed-through with one close-up plug.
Listed File No. E91049
Certified File No. LR14667
PUSH TO
TEST
O
F
F
O
N
R
E
S
E
T
Typical Application with
XHL Series Hand Lamp
PUSH TO
TEST
O
F
F
O
N
R
E
S
E
T
7 3/8
6
6 1/8
7 7/8
Hard-Wired Unit
• Adapter Unit
Class I, Div. 2, Groups B,C,D
Class I, Zone 2, Groups IIB+H2, IIA
Class II, Div. 1 & 2, Groups F,G
Class III, Div. 1 & 2
• Hard-Wired Unit
Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones 1 & 2, Groups IIB+ H2, IIA
Class II, Div. 1 & 2, Groups F,G
Class III, Div. 1 & 2
NEMA 3 ENCLOSURE TYPE
(Adapter or Hard-Wired units)
Adapter Unit
No need to permanently alter existing
installations; Portable Unit can be
temporarily hung using included strap
near an existing receptacle wherever
protection is required
Factory Sealed Unit
Acceptor®plug and cord set included
with Adapter Unit. Cord is 36"
Hard-Wired Unit
provides GFCI and circuit protection
in new installations, or as an upgrade
or replacement for non-GFCI
receptacles
Factory Sealed, except Group B
Adapter and Hard-Wired Unit
GFCI device also provides circuit
protection, for connected apparatus,
against current overload and short
circuits
Acceptor®receptacles and plugs
are interchangeable with both
Crouse-Hinds®Ark-Gard®2 and
Appleton®U-Line®products®
Amber pilot light provides indication
that the receptacle is energized.
Units can be Padlocked OFF for
maintained safety
Fully gasketed GFCI compartment
prevents moisture from damaging
electronic components
Same high quality materials as the
standard ACCEPTOR®
1Hard-Wired assemblies in Group B areas require
sealing within 6" of enclosure.
2Exact models classified for interchangeability
are listed in the information sheet provided with
the products.
32P 250V units are cCSAus for 2P “hot line”
applications and include 2+ 5mA GFI breakers.
Ark-Gard®is a registered trademark of
Crouse-Hinds®.
U-Line®is a registered trademark of Appleton
Electric Company®.
Adapter Unit
UGFI
GROUND FAULT
PROTECTOR
20A
125V
15A
125V
20A
250V
15A
250V
UGFI20AD
UGFI15AD
UGFI202AD
3
UGFI152AD
3
5-20R
5-15R
6-20R
6-15R
20A
125V
15A
125V
1/2” HUB UGFI20C1
3/4” HUB UGFI20C2
1” HUB UGFI20C3
1/2” HUB UGFI15C1
3/4” HUB UGFI15C2
1” HUB UGFI15C3
5-20R
5-15R
6-20R
6-15R
20A
250V
15A
250V
1/2” HUB UGFI202C1
3/4” HUB UGFI202C2
1” HUB UGFI202C3
1/2” HUB UGFI152C1
3/4” HUB UGFI152C2
1” HUB UGFI152C3
HARD WIRED (PERMANENTLY MOUNTED)
GFCI RECEPTACLE
NEW!
2P 250V GFI
CONTORLS INDEX
Section C
Ci
D2C Series
DuraTech Control Stations ...................2 - 5
D2C Series
Dimensional Data ................................6 - 7
XCS/XS/SWB Series
Control Stations
External Sealing Required................18 - 25
SWB Series
Device Boxes..........................................19
SWB Series
Conduit Opening Data ............................20
XCS Series
Cover Assemblies Control Stations ......21 - 25
XCS Series
Blank Covers...........................................26
FXCS/XCS Series
Accessories, Replacement Parts..........26 - 27
XS Series
Tumbler Switch........................................28
XAL/XAS Series
Fire Alarm Stations..................................29
CS Series
CONSPEC Control Stations...................8 - 10
CS Series
Dimensional Data
Catalog Logic .........................................11
FXCS Series
Seal-X Factory
Sealed Control Stations....................12 - 17
FXB Series
Seal-X Splice Boxes................................13
FXCS Series
Seal-X Factory Sealed
Cover Assemblies ............................14 - 17
C
Cii
CONTORLS INDEX
Section C
G Series
Custom Control Panel Operators
Push Buttons, Pilot Lights,
Selector Switches ............................30 - 35
G Series
Specialty Operators ................................36
G Series
Operator Bodies......................................37
G Series
Accessories/Replacement Parts ......38 - 39
G Series
Operator Ordering System
and Symbols....................................40 - 41
G Series
Dimensions .............................................42
Y7 Series
Motor Starters-Magnetic Line Starters......50
Y7 Series
Combination Motor Starter ......................51
Y7 Series
Motor Starters-Modifications ...................52
XSD/XSX/FXSD/FXSX Series
Manual Motor Starting Switches ..............53
XSD/XSX/FXSD/FXSX Series
Heaters, Dimensions ...............................54
B7MS Series
Compact Manual IEC Starters..........55 - 56
B7MS Series
Compact Manual NEMA Starters..........57 - 58
XMSW Series
Manual Line Starters ...............................59
B7 Series
Prism Magnetic Motor Starters .........43 - 45
B7 Series
Prism Combination Starters.....................46
B7 Series
Dimensions, Accessories,
Catalog Logic ..................................47 - 48
B7 Series
Overload Heaters,
Non-Reversing Data................................49
D2C SERIES CONTROLS
CONTROL STATIONS - NON-METALLIC
C2
FEATURES-SPECIFICATIONS
Class I, Div. 2, Groups A,B,C,D
Class l, Zone 2, Groups IIC, llB, llA
NEMA 3, 4, 4X, 7 (Div.2)
Applications
Hazardous and corrosive environments
such as refineries, chemical plants, water
treatment and bio gas plants, and wher-
ever a combustible gas-air mixture may
occur.
Features
Enclosures of rugged polyester resin
and gasketed for NEMA 4X hose down
protection
Factory sealed contacts rated for heavy
duty NEMA A600/Q300 explo-
sion-protected operation
No external seals required for most
applications
Comprehensive selection of control
operators including:
Push buttons (standard or mushroom
caps) with momentary & maintained
action for multiple functions or
emergency stop
Rotary selector switches for maintained
or momentary operation
Pilot lights (LED as standard) in multiple
voltages and colors
Options for various enclosures entry
types and legend plates
PRODUCT LINE OVERVIEW
ASSEMBLIES
CONTROL DEVICES
One device
ENCLOSURES
ENTRIES AND ACCESSORIES
Two devices Three devices
Push Button
Control Switch
Pilot Light
Size 1 Size 2
Hub with
Grounding locknut
Legend
Plates
Shrouded or mushroom style Maintained push-pull or twist-release button
Multiple position rotary maintained or momentary action
Full voltage, resistor or transformer and multi-voltage LED types
Hole Plug Lockouts
Factory Sealed
Contact Block
1N.O./1N.C.
ONE DEVICE, DEAD END1
Single Push Button (Momentary Contact)
Complete Units (Box & Cover) NPT SIZE DIAGRAM COLOR LEGEND2
D2CG2B1 GREEN START
D2CG2B2 RED STOP
D2CG2B3 BLACK BLANK
Push-Pull Mushroom Button (Maintained Contact)
D2CG2MMR3 RED EMERGENCY STOP
Pilot Light (120V AC Light Emitting Diode Type)
D2CG2B24CL CLEAR BLANK
D2CG2B24GL GREEN BLANK
D2CG2B24RL RED BLANK
D2CG2B24BL BLUE BLANK
D2CG2B24AL AMBER BLANK
D2CG2B24WL WHITE BLANK
2 Position Rotary Selector Switch (Maintained Contact) LEGEND
D2CG2S2A3 3/4” OFF - ON
3 Position Rotary Selector Switch (Maintained Contact)
D2CG2S3C3 3/4” HAND-OFF-AUTO
D2C SERIES CONTROLS
ASSEMBLED CONTROL STATIONS C3
FEATURES-SPECIFICATIONS
C
D2CG2B2 D2CG2MMR3 D2CG2S3C3 D2CG2B7
D2CG8B15
The control stations on this page are the most commonly used configurations, including combinations of push buttons, pilot lights and
selector switches. See the following pages for components to configure custom stations.
3/4”
3/4”
3/4”
DIAGRAM
LEFT CENTER RIGHT
TWO DEVICES, DEAD END1
Two Push Buttons (Both Momentary Contact)
Complete Units (Box & Cover) NPT SIZE DIAGRAM COLOR LEGEND2
D2CG2B4 GREEN - RED START - STOP
D2CG2B7 BLACK - BLACK BLANK
Pilot Light (120V AC Light Emitting Diode Type) and Push Button (Momentary Contact)
D2CG2B13 RED LENS, BLACK BUTTON BLANK
3/4”
3/4”
THREE DEVICES, DEAD END1
Pilot Light (120V AC Light Emitting Diode Type) and two push buttons (Both Momentary Contact)
Complete Units (Box & Cover) NPT SIZE DIAGRAM COLOR LEGEND2
D2CG8B15 RED LENS, GREEN BLANK, START, STOP
& RED BUTTONS
Three Push Buttons (Each Momentary Contact)
D2CG8B9 GREEN, RED START, STOP, BLANK
& BLACK BUTTONS
3/4”
3/4”
1For 3/4” FEED-THRU, change G2 or G8 in catalog number to G5. Example D2CG2B1 becomes D2CG5B1. For other hub sizes, see page C4.
2Specify pilot light lens marking or blank button marking if required.
D2C SERIES CONTROLS
ENCLOSURES, ENTRY FITTINGS, ACCESSORIES, LEGENDS
C4
FEATURES-SPECIFICATIONS
PWBG
SIZE 1
PWCG10
D2CCG12
D2CCG11 PWBG
SIZE 2
PWCG20 D2CCG23 D2CCG24
SIZE 1 BOXES
Catalog Number Description
PWBG0 Blank - No Entries
PWBG1 w/1/2” NPT hub, dead end
PWBG2 w/3/4” NPT hub, dead end
PWBG3 w/1” NPT hub, dead end
PWBG4 w/1/2” NPT hubs, feed thru
PWBG5 w/3/4” NPT hubs, feed thru
PWBG6 w/1” NPT hubs, feed thru
PWBG25 w/clearance hole, 1/2” NPS
PWBG26 w/clearance hole, 3/4” NPS
PWBG27 w/clearance hole, 1” NPS
PWBG37 w/clearance hole, M2O
PWBG38 w/clearance hole, M25
PWBG39 w/clearance hole, M32
SIZE 1 COVERS
PWCG10 Blank-no device openings
D2CCG11 w/1 device opening 30mm
D2CCG12 w/2 device openings 30mm
SIZE 2 BOXES
Catalog Number Description
PWBG00 Blank - No Entries
PWBG7 w/1/2” NPT hub, dead end
PWBG8 w/3/4” NPT hub, dead end
PWBG9 w/1” NPT hub, dead end
PWBG10 w/1/2” NPT hubs, feed thru
PWBG11 w/3/4” NPT hubs, feed thru
PWBG12 w/1” NPT hubs, feed thru
PWBG31 w/clearance hole, 1/2” NPS
PWBG32 w/clearance hole, 3/4” NPS
PWBG33 w/clearance hole, 1” NPS
PWBG43 w/clearance hole, M20
PWBG44 w/clearance hole, M25
PWBG45 w/clearance hole, M32
SIZE 2 COVERS
PWCG20 Blank-no device openings
D2CG23 w/3 device openingS 30mm
D2CG24* w/4 device openings 30mm
ENTRY FITTINGS** & ACCESSORIES
Catalog Number Description
WH-1G Hub w/grounding locknut 1/2” NPT
WH-2G Hub w/grounding locknut 3/4” NPT
WH-3G Hub w/grounding locknut 1” NPT
YOCCHP Hole plug for 30mm operator
YOCCLOAX Lockout for half shroud momentary buttons
YOCCLOAM Lockout for momentary mushroom buttons
YOCCLOAP Lockout for maintained mushroom buttons
YOCCLOAFC Lockout cover (clear) for buttons or switches
** For other entry openings, contact factory.
* Space restrictions may apply for feed thru conduit entries.
LEGEND PLATES***
Blue plate with white lettering - add to end of base catalog
number YOCCLPBE. Example YOCCLPBE02.
Blank plates for engraving - add to end of base catalog
number YOCCLP. Example YOCCLPBE00.
*** contact factory for additional selections.
02 = CLOSE
03 = DOWN
04 = EMERGENCY STOP
07 = FORWARD
14 = OPEN
15 = POWER OFF
16 = POWER ON
17 = PUSH TO TEST
18 = RESET
BE00 = Blue Plate
GN00 =Green Plate
RD00 = Red Plate
19 = REVERSE
20 = RUN
22 = START
23 = STOP
24 = TEST
25 = UP
30 = PUSH TO RESET
56 = OFF - ON
83 = HAND - OFF - AUTO
WE00 = White Plate
YW00 = Yellow Plate
00 = Black Plate
D2C SERIES CONTROLS
CONTROL OPERATORS, CONTACT BLOCKS C5
FEATURES-SPECIFICATIONS
C
* Operators supplied with one universal factory sealed 1 N.O. + 1 N.C. contact block. For
operator provided with two contact blocks, change last digit (3) of catalog number to 8.
For actuator only, change (3) to O.
Push Button - Momentary
Mushroom - Maintained
Rotary Switch
Pilot Light - LED
Factory Sealed
Contact Block
1 N.O./1 N.C.
Momentary Push Button Operators*
Catalog Number Description
D2CO1KX3 Black Push Button Full Shroud
D2CO1GX3 Green Push Button Full Shroud
D2CO1RX3 Red Push Button Full Shroud
D2CO1KH3 Black Push Button Half Shroud
D2CO1GH3 Green Push Button Half Shroud
D2CO1RH3 Red Push Button Half Shroud
D2CO1KM3 Black Push Button Mushroom
D2CO1GM3 Green Push Button Mushroom
D2CO1RM3 Red Push Button Mushroom
Maintained Mushroom Push Button Operators*
D2COM1K3 Black Push-Pull Mushroom
D2COM1G3 Green Push-Pull Mushroom
D2COM1R3 Red Push-Pull Mushroom
D2COT1R3 Red Twist to Release Mushroom
Rotary Selector Switch Operators*
D2CO52A3 Maintained 2-Position
D2CO53C3 Maintained 3-Position
D2CO63 Momentary Right, 2-Position
D2CO73 Maintained Center 3-Position
D2CO143 Maintained Left & Center 3-Position
D2CO153 Maintained Right & Center 3-Position
LED Pilot Light Devices
Add to end of base catalog number D2CO3. Example D2CO3A23.
A23 = Amber 120V AC/DC
A4 = Amber 24V AC/DC
AMV = Amber Multi-voltage 20V-254V AC/DC
B23 = Blue 120V AC/DC
B4 = Blue 24V AC/DC
BMV = Blue Multi-voltage 20V-254V AC/DC
C23 = Clear 120V AC/DC
C4 = Clear 24V AC/DC
CMV = Clear Multi-voltage 20V-254V AC/DC
G23 = Green 120V AC/DC
G4 = Green 24V AC/DC
GMV = Green Multi-voltage 20V-254V AC/DC
R23 = Red 120V AC/DC
R25R = Red 480VAC/DC resistor
R25T = Red 480VAC transformer
R4 = Red 24V AC/DC
RMV = Red multi-voltage 20V-254V AC/DC
W23 = White frosted 120V AC/DC
W4 = White frosted 24V AC/DC
WMV = White frosted Multi-voltage 20V-254V AC/DC
Factory Sealed Contact Block
Catalog Number Description Diagram
D2CU Factory Sealed Contact Block
(add suffix R for rotary 1 Normally Open and
selector switches) 1 Normally closed
Hazardous Rating:
Class I, Division 2, Groups A,B,C,D; Class I, Zone 2, Groups IIB+H2, IIA, T6
Terminal Capacity:
22 thru 12 AWG [0.5-2.5mm2] copper, solid or standed conductors.
Tightening torque 7 in-lbs. (tolerance +3.0/0.0) [~ 0.8Nm]
Contact Electrical Ratings:
NEMA A600- 7200 VA (Make), 720 VA (Break), 10 Amps Cont. @600V AC (Thermal)
NEMA Q300- 69 VA (Make & Break), 2.5 Amps Cont. @250V DC (Thermal)
Design your own DuraTech®configuration from components by completing the following:
Box Size  Hub Size  Dead End Feed Thru
Clearance Hole NPS  Metric 
Cover Size  Number of Devices 
Select Devices From Top (Position 1) to Bottom
Position 1__________________________________________________________________________________________________________________________________________________________________________________________________________
Position 2__________________________________________________________________________________________________________________________________________________________________________________________________________
Position 3__________________________________________________________________________________________________________________________________________________________________________________________________________
Position 4__________________________________________________________________________________________________________________________________________________________________________________________________________
D2C SERIES CONTROLS
CUSTOM STATIONS ORDERING FORM, ENCLOSURE DIMENSIONS
C6
Device Nameplate Options
1 2
1 2 1 2 3 4
1/2 3/4 1
1/2 3/4 1 M20 M25 M32
D2C SERIES CONTROLS
CONTROLS OPERATOR DIMENSIONS C7
C
Operators bought separately are provided with gaskets to accommodate panel thickness for D2C series enclosures.
Full-Shrouded Momentary Push Button Operator
(53) (63)
(11)
(21)
Half-Shrouded Button
Mushroom Push Button Selector Switch Device
Pilot Light Multi-Voltage 20V-240V AC/DC Pilot Light 120V AC (Full Voltage)
Legend Plate
(53) (53) (63)
CS SERIES CONTROLS
CONTROL STATIONS
C8
FEATURES-SPECIFICATIONS
Stainless Steel Enclosure
FRP Enclosure
Class I, Div. 2, Groups A,B,C,D
Class l, Zones 1 & 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G1
Class III
NEMA 3, 4, 4x
(A)Ex de IIC T6 IP66
Applications
Hazardous and corrosive environments
such as refineries, chemical plants,
water treatment and bio gas plants, and
wherever a combustible gas-air mixture
or combustible dust may occur.
Features
Enclosures of Fiberglass Reinforced
Polyester or Stainless Steel.
Durable EPDM gasket on enclosure
is concealed to protect it from
damage or premature aging by UV
light and chemical elements
Snap-on mounting of individual explo-
sion-protected control components to
notched DIN-like rail
Contact element utilizes a parallel
bridge contact with a four point
(H- contact) to ensure the utmost
reliability even with very low control
voltages and currents
Fluorosilicate gasket in standard
pushbutton actuators is suitable for a
wide range of atmospheric conditions
(-50°C to 40°C)
LED Pilot lights (incorporating
advanced voltage-sensing electronics)
operate on any voltage from 20V- 254V,
AC or DC
Control switches in many configura-
tions
Illuminated (Push-To-Test) push but-
tons, ammeters, potentiometers and
other control components available
No external seals required for most
applications
RUN
Two Types of Enclosure Materials
• Fiberglass Reinforced Polyester (FRP)
• 316L Stainless Steel
Pilot Light Bezel
Station I.D. Label
(optional)
Actuator Gasket
Conduit Hub
or Cable
Gland Entry
Ground Plate
With Terminals
Explosion
Protected
Contact Block
Spring Washer
& Retainer Nut
Recessed
EPDM
Gasketing
Integral
Mounting Slots (holes)
Component
Mounting Rail
Stainless Steel Cover Screws
Explosion Protected
LED Pilot Light
“THE” Standard in Hazardous
Location Control
1CSA Certified for Class II, Div. 1&2, EFG. UL LIsted for Class II, Div. 2, FG. Easy Change-out
Components Snap in Place
Dual Push-Button Actuator
CS SERIES CONTROLS
CONTROL STATIONS - STANDARD CONFIGURATIONS
FEATURES-SPECIFICATIONS
C
C9
Start
Push Button
Station
Start/Stop
Push Button
Station
E-Stop
Push Button
Station
Pilot Light
Station
Class I, Div. 2, Groups A,B,C,D
Class l, Zones 1 & 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G1
Class III
NEMA 3, 4, 4X
(A)Ex de IICT6 IP66
CATALOG
NUMBER
CONTACT ARRANGEMENT
IEC NEMA
CONTACT
BLOCKS
BUTTON
COLOR
NAMEPLATE
MARKING
CS MOMENTARY SINGLE PUSH BUTTON
The control stations on this page are
the most commonly used configura-
tions, including combinations of pilot
lights and push buttons.
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
(Standard for IEC/CENELEC)
M25 Compression Gland Top Feed
M25 Compression Gland Bottom Feed
M25 Compression Gland Feed Through
Special
BOXES WITH CONDUIT HUB
BOXES WITH NON-METALLIC CABLE GLAND
BOXES WITH INTERNAL GROUND PLATE
(for MC/TC/TEC Cable Connectors)
1/2" NPT Top Feed
1/2" NPT Bottom Feed
1/2" NPT Feed Through
3/4" NPT Top Feed
3/4" NPT Bottom Feed
3/4" NPT Feed Through
1/2" NPT Top Feed
1/2" NPT Bottom Feed
1/2" NPT Feed Through
3/4" NPT Top Feed
3/4" NPT Bottom Feed
3/4" NPT Feed Through
Wiring Entry Logic
Insert one of the digits below to complete the
control station catalog number.
CSF124UO11
CSS124UO11
CATALOG
NUMBER
CONTACT ARRANGEMENT
IEC NEMA
CONTACT
BLOCKS
BUTTON
COLOR
NAMEPLATE
MARKING
CS MOMENTARY START-STOP PUSH BUTTONS
1 N.O. / 1 N.C.
1 N.O. / 1 N.C.
CATALOG
NUMBER
CONTACT ARRANGEMENT
IEC NEMA
CONTACT
BLOCKS
BUTTON
COLOR
NAMEPLATE
MARKING
CS MAINTAINED EMERGENCY STOP PUSH BUTTON
CATALOG
NUMBER
CONTACT ARRANGEMENT
IEC NEMA VOLT COLOR NAMEPLATE
MARKING
CS SINGLE PILOT LIGHT
Wiring entry: 4=3/4" NPT Bottom Feed. For other entries, see Wiring Entry Logic table at left.
Housing material: (F) FRP, (S) Stainless Steel.
1CSA Certified for Class II, Div. 1&2, EFG.
UL Listed for Class II, Div. 2, FG.
1 N.O. / 1 N.C. Green Start
23 11
24 12
Green
Red
Start
Stop
23 11
24 12
23 11
2412
START STOP
2 N.C. E-Stop
Red Large
I-0 12
11
22
21
CSF124C150
CSS124C150
CSF224UO11UO12
CSS224UO11UO12
20V-254V AC / DC Red LED
CSF124PLRO
CSS124PLRO
X1 X2
CS SERIES CONTROLS
CONTROL STATIONS - STANDARD CONFIGURATIONS
C10
FEATURES-SPECIFICATIONS
Pilot Light and
Selector Switch
Station
Pilot Light &
Start/Stop Push
Button Station
Selector Switch
Station
Pilot Light &
2 Push Button
Station
Class I, Div. 2, Groups A,B,C,D
Class l, Zones 1 & 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G1
Class III
NEMA 3, 4, 4X
(A)Ex de IICT6 IP66
The control stations on this page are
the most commonly used configura-
tions, including combinations of pilot
lights, push buttons and selector
switches.
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
(Standard for IEC/CENELEC)
M25 Compression Gland Top Feed
M25 Compression Gland Bottom Feed
M25 Compression Gland Feed Through
Special
BOXES WITH CONDUIT HUB
BOXES WITH NON-METALLIC CABLE GLAND
BOXES WITH INTERNAL GROUND PLATE
(for MC/TC/TEC Cable Connectors)
1/2" NPT Top Feed
1/2" NPT Bottom Feed
1/2" NPT Feed Through
3/4" NPT Top Feed
3/4" NPT Bottom Feed
3/4" NPT Feed Through
1/2" NPT Top Feed
1/2" NPT Bottom Feed
1/2" NPT Feed Through
3/4" NPT Top Feed
3/4" NPT Bottom Feed
3/4" NPT Feed Through
Wiring Entry Logic
Insert one of the digits below to complete the
control station catalog number.
CONTACT ARRANGEMENT
IEC NEMA
CS PILOT LIGHT (RED LED)/MOMENTARY DOUBLE PUSH BUTTONS
CSF334PLROU011U012
CSS334PLROU011U012
CSF224PLROU231
CSS224PLROU231
CONTACT ARRANGEMENT
IEC NEMA
CS PILOT LIGHT (RED LED)/MOMENTARY START-STOP PUSH BUTTONS
CONTACT ARRANGEMENT
IEC NEMA
CS MAINTAINED 2-POSITION SELECTOR SWITCH
2-Pos./2-Pole Off-On
CONTACT ARRANGEMENT
IEC NEMA
CS PILOT LIGHT/MAINTAINED 2-POSITION SELECTOR SWITCH
Off-On
Wiring entry: 4=3/4" NPT Bottom Feed. For other entries, see Wiring Entry Logic table at left.
Housing material: (F) FRP, (S) Stainless Steel.
CONTACT ARRANGEMENT
IEC NEMA
CS MAINTAINED 3-POSITION SELECTOR SWITCH
3-Pos./2-Pole
45°13 5 °
14
24
13
23
13 23
14 24
°°
°°
OFF ON
45°13 5 °
12
24
11
23
11 23
12 24
°°
°°
90°
OFF AUTO
4HAND
NAMEPLATE
MARKING
Start
Stop
BUTTON
COLOR
VOLT CONTACT
BLOCKS
20V-254V, AC/DC
NAMEPLATE
MARKING
Green
Red
Start
Stop
Green
Red
1 N.O./1 N.C.
BUTTON
COLOR
VOLT CONTACT
BLOCKS
20V-254V, AC/DC
1 N.O. / 1 N.C.
1 N.O. / 1 N.C.
NAMEPLATE
MARKING
COLOR
VOLT CONTACT
BLOCKS
20V-254V, AC/DC 2-Pos./2-Pole Red LED
CATALOG
NUMBER
CATALOG
NUMBER
CATALOG
NUMBER
CATALOG
NUMBER
CATALOG
NUMBER
CONTACT
BLOCKS
BUTTON
COLOR
NAMEPLATE
MARKING
CONTACT
BLOCKS
BUTTON
COLOR
NAMEPLATE
MARKING
X1 X2
23
24
11
12
1CSA Certified for Class II, Div. 1&2, EFG.
UL LIsted for Class II, Div. 2, FG.
START STOP
X1 X2
23 11
24 12
23 11
24 12
START STOP
CSF124NO21
CSS124NO21
H-O-A
CSF124N273
CSS124N273
CSF224PLRON021
CSS224PLRON021
45° 135°
14
24
13
23
13 23
14 24
°°
°°
OFF ON
CS SERIES CONTROLS
CONTROL STATIONS DIMENSIONAL DATA C11
FEATURES-SPECIFICATIONS
C
Stainless Steel Enclosure
FRP Enclosure
FRP Dimensions
Steel Dimensions
AB
0.2"
(5.5)
1.9"
(48)
3.7"
(93)
0.2"
(5.5)
0.3"
(7)
2.8"
(70)
3.1"
(80)
ø 0.2"
(ø 5.5)
AB
0.2"
(5.5)
0.2"
(5.5)
3.7"
(94)
5.5"
(139)
0.3"
(7)
2.8"
(70)
3.1"
(80)
ø 0.2"
ø (5.5)
7.3"
(185)
AB
0.2"
(5.5)
0.2"
(5.5)
5.5"
(140)
0.3"
(7)
2.8"
(70)
3.1"
(80)
ø 0.2"
ø (5.5)
3.78
(97)
.43"
(11)
CSF 11 Compact
CSS 12
CSS 22
CSS 33
CSF12/CSF 22 CSF 33 CSF Deep
for 4 Pole Switches
8.2” (207)
8.9” (226)
C12 FXCS SERIES CONTROLS
FACTORY SEALED CONTROLS
FEATURES-SPECIFICATIONS
Applications
SEAL-X®Series Factory Sealed push
button stations, selector switches, pilot
lights and tumbler switches are used to
prevent the igniting of external haz-
ardous atmospheres by the enclosed
arcing devices in such areas as:
Hazardous locations due to the pres-
ence of flammable gases or vapors,
combustible dusts or easily ignitable
fibers or flyings
Installations at petroleum refineries,
chemical and petrochemical plants
and other processing or storage facil-
ities where similar hazards exist
Use in conjunction with magnetic
starters or contactors for remote con-
trol of motors
Features
Elimination of external sealing
requirements
Lower installation cost
NEMA 3 weatherproof
Color coded wiring-more wiring
space-easier field installation
Stainless steel captive screws for
cover assembly
Ground boss for grounding in the
splice box
Device bodies and covers are cast
copper-free aluminum alloy
Listed - File E53360
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 7(C,D) 9(E,F,G)
Cast conduit hubs 1/2", 3/4" and 1"
either dead end or feed through
standard in both single and two
gang assemblies
Push button, selector switches and
pilot light bodies are copper-free
aluminum
Operating shaft in both push buttons
and selector switches are stainless
steel
Miniature and standard size push
buttons. (Miniature 3/4" overall diam-
eter, standard 1 3/8" overall diameter)
Factory Sealed devices eliminate the
need for external sealing. The differ-
ence is the use of a sealing plate
between the arcing device and the
junction box. The sealing plate con-
fines ignited gases, vapors, flames,
or dust to the arcing device chamber,
preventing them from traveling through
the conduit system. Accurately ground
flanges on both sides of the sealing
plate provide flame-tight joints. Factory
poured seals around the wiring pigtails
insure safe sealing. (FXCS Series)
CURRENT 120 VAC 240 VAC 480 VAC 600 VAC
INRUSH 60 30 15 12
BREAKING 631.5 1.2
CARRYING 10 10 1 0 10
CONTACT BLOCK RATINGS
CURRENT 125 VDC 250 VDC
INRUSH .55 .275
BREAKING .55 .275
CARRYING 2. 5 0 2.50
DC RATINGS (MAX. AMPS)
SUFFIX DESCRIPTION
NUMBER
MODIFICATIONS
AL Pilot light lens-amber
CL Pilot light lens-clear
GL Pilot light lens-green
RL Pilot light lens-red
MR Mushroom head-
Push button (red)
LO Push button LOCKOUT1
LOP Selector switch-padlock
LOCKOUT
1LOCKOUT must be installed at the factory.
LED lamps available. See page C39.
Electrical Rating
Push button stations, selector switches
600 VAC max. heavy duty.
SEAL-X®
C13
C
FXB SERIES CONTROLS
FACTORY SEALED SPLICE BOXES/SEALING METHODS
FEATURES-SPECIFICATIONS
FXB-2
Dead End
FXB-8
Double Gang Dead End
FXB-11
Double Gang Feed Thru
Listed - File E53360
Certified- File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. I & 2, Groups E,F,G
Class Ill
NEMA 3, 7(C,D) 9(E,F,G)
Splice Boxes
The FXB Series of splice boxes are
designed for use with the FXCS and
FXS Series of cover sub-assemblies.
FXB BACK BOX SELECTION AND DIMENSIONS
CATALOG NUMBER DESCRIPTION
FXB-1
FXB-2
FXB-3
FXB-4
FXB-5
FXB-6
FXB-7
FXB-8
FXB-9
FXB-10
FXB-11
FXB-12
Single gang/Dead-end
Single gang/Dead-end
Single gang/Dead-end
Single gang/Feed-thru
Single gang/Feed-thru
Single gang/Feed-thru
Double gang/Dead-end
Double gang/Dead-end
Double gang/Dead-end
Double gang/Feed-thru
Double gang/Feed-thru
Double gang/Feed-thru
MOUNTING
EXTERNAL
HUB
SIZE LENGTH WIDTH DEPTH HORIZONTALVERTICAL
1/2"
3/4"
1"
1/2"
3/4"
1"
1/2"
3/4"
1"
1/2"
3/4"
1"
6-13/16"
6-13/16"
6-13/16"
6-13/16"
6-13/16"
6-13/16"
6-13/16"
6-13/16"
7
6-13/16"
6-13/16"
7
3-11/16"
3-11/16"
3-11/16"
3-11/16"
3-11/16"
3-11/16"
7-17/32"
7-17/32"
7-17/32"
7-17/32"
7-17/32"
7-17/32"
1-3/4"
1-3/4"
1-3/4"
1-3/4"
1-3/4"
1-3/4"
2
2
2
2
2
2
6-3/16"
6-3/16"
6-3/16"
6-3/16"
6-3/16"
6-3/16"
6-3/16"
6-3/16"
6-3/16"
6-3/16"
6-3/16"
6-3/16"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
2-1/4"
FXB-5
Feed Thru
C14 FXCS SERIES CONTROLS
FACTORY SEALED COVER ASSEMBLIES
FEATURES-SPECIFICATIONS
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. I & 2, Groups E,F,G
Class Ill
NEMA 3, 7(C,D) 9(E,F,G)
Listed - File E53360 and/or E12379
Certified - File LR11714
See files for details or call Killark.
Single Push Button Double Push Button Pilot Light
CATALOG NUMBER
NAMEPLATE
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM BUTTON
MARKING1
COVER WITH DEVICE DEAD-END FEED-THRU SIZE COLOR
FXCS-0B1 FXCS-1B1 FXCS-4B1 1/2" Green Start
FXCS-2B1 FXCS-5B1 3/4"
FXCS-0B2 FXCS-1B2 FXCS-4B2 1/2" Red Stop
FXCS-2B2 FXCS-5B2 3/4"
FXCS-0B3 FXCS-1B3 FXCS-4B3 1/2" Black Specify
FXCS-2B3 FXCS-5B3 3/4"
FXCS MOMENTARY CONTACT SINGLE PUSH BUTTON
CATALOG NUMBER
NAMEPLATE
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM BUTTON
MARKING1
COVER WITH DEVICE DEAD-END FEED-THRU SIZE COLOR
FXCS-1B4 FXCS-4B4 1/2" Green/Red Start/Stop
FXCS-0B4 FXCS-2B4 FXCS-5B4 3/4"
FXCS-0B4-U FXCS-1B4U FXCS-4B4-U 1/2" Green/Red Start/Stop
FXCS-2B4U FXCS-5B4-U 3/4"
FXCS-0B5 FXCS-1B5 FXCS-4B5 1/2" Green/Green Start/Stop
FXCS-2B5 FXCS-5B5 3/4"
FXCS-0B7 FXCS-1B7 FXCS-4B7 1/2" Black/Black Specify
FXCS-2B7 FXCS-5B7 3/4"
FXCS MOMENTARY CONTACT DOUBLE PUSH BUTTON
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM VOLT LENS NAMEPLATE
COVER WITH DEVICE DEAD-END FEED-THRU SIZE COLOR2MARKING1
FXCS-0B24CL FXCS-1B24CL FXCS-4B24CL 1/2" 120V Clear Specify
FXCS-2B24CL FXCS-5B24CL 3/4"
FXCS-0B24GL FXCS-1B24GL FXCS-4B24GL 1/2" 120V Green Specify
FXCS-2B24GL FXCS-5B24GL 3/4"
FXCS-0B24RL FXCS-1B24RL FXCS-4B24RL 1/2" 120V Red Specify
FXCS-2B24RL FXCS-5B24RL 3/4"
FXCS PILOT LIGHT
1For other than standard marking, refer to the special feature section of price list.
2Lens colors other than listed may be specified by changing lens color suffix. See modifications page C12.
NOTE: Boxes and covers shipped separately.
*For control stations with 1" conduit openings or for double gang assemblies, order cover with device and box as separate components.
• •
• •
• •
• •
• •
• •
• •
• • • •
• •
• •
• • • •
• •
• •
• •
C15
C
FXCS SERIES CONTROLS
FACTORY SEALED CONTROL STATION COVER ASSEMBLIES
FEATURES-SPECIFICATIONS
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, IlA
Class II, Div. I & 2, Groups E,F,G Class Ill
NEMA 3, 7(C,D) 9(E,F,G)
Listed - File E53360 and /or E12379
Certified - File LR11714
See files for details or call Killark.
Double Pilot Lights
Pilot Light
Push Button
Pilot Light
Two Mini Push Buttons
Maintained
Push Button
1For other than standard marking, refer to the special feature section of price list.
2Lens colors other than listed may be specified by changing lens color suffix. See modifications page C12.
3Three nameplates supplied (Start/Stop, Blank, Emergency Stop) with FXCS maintained push button.
4Operation-when push button is depressed and contacts activated, operator will remain in depressed position until pulled out to
normal position.
NOTE: Boxes and covers shipped separately.
*For control stations with 1" conduit opening or for double gang assemblies, order cover with device and box as separate components.
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM LAMP LENS NAMEPLATE
COVER WITH DEVICE DEAD-END FEED-THRU SIZE VOLTS COLOR2MARKING1
FXCS-0B30CL FXCS-1B30CL FXCS-4B30CL 1/2" 120V Clear Specify
FXCS-2B30CL FXCS-5B30CL 3/4"
FXCS-0B30GL FXCS-1B30GL FXCS-4B30GL 1/2" 120V Green Specify
FXCS-2B30GL FXCS-5B30GL 3/4"
FXCS-0B30RL FXCS-1B30RL FXCS-4B30RL 1/2" 120V Red Specify
FXCS-2B30RL FXCS-5B30RL 3/4"
FXCS-0B30RL-GL FXCS-1B30RL-GL FXCS-4B30RL-GL 1/2"
FXCS-2B30RL-GL FXCS-5B30RL-GL 3/4" 120V Red/Green Specify
FXCS DOUBLE PILOT LIGHTS
CATALOG NUMBER NAMEPLATE
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM BUTTON LENS MARKING1
COVER WITH DEVICE DEAD-END FEED-THRU SIZE COLOR COLOR2BUTTON LENS
FXCS-0B13-C FXCS-1B13-C FXCS-4B13-C 1/2" Red Clear Stop Specify
FXCS-2B13-C FXCS-5B13-C 3/4"
FXCS-0B13-O FXCS-1B13-O FXCS-4B13-O 1/2" Green Green Start Specify
FXCS-2B13-O FXCS-5B13-O 3/4"
FXCS-0B13-U FXCS-1B13-U FXCS-4B13-U 1/2" Black Red Specify Specify
FXCS-2B13-U FXCS-5B13-U 3/4"
FXCS MOMENTARY CONTACT PUSH BUTTON AND PILOT LIGHT
• •
LAMP
VOLTS
120V
120V
120V
CATALOG NUMBER NAMEPLATE
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM BUTTON LENS MARKING1
COVER WITH DEVICE DEAD-END FEED-THRU SIZE COLOR COLOR2BUTTON LENS
FXCS-0A15 FXCS-1A15 FXCS-4A15 1/2"
Red/Green Red
FXCS-2A15 FXCS-5A15 3/4" 120 VAC
FXCS MOMENTARY CONTACT 2 MINI PUSH BUTTON AND 1 PILOT LIGHT
Stop
Start Specify
• •
• •
• •
• •
FXCS MAINTAINED CONTACT - PUSH/PULL MUSHROOM4
BUTTON COLOR
GREEN
RED
BLACK
CONTACT TYPE
1NO/1NC
1NO/1NC
1NO/1NC
COVER ASSEMBLY CAT. #
FXCS-OMMG3
FXCS-OMMR3
FXCS-OMMK3
CATALOG # WITH LOCKOUT #
FXCS-OMMR3-LOM
NAMEPLATE MARKING
3
C16 FXCS SERIES CONTROLS
FACTORY SEALED COVER ASSEMBLIES
FEATURES-SPECIFICATIONS
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, lIA
Class II, Div. 1 & 2, Groups E,F,G Class Ill
NEMA 3, 7(C,D) 9(E,F,G)
Listed - File E53360 and/or E12379
Certified - File LR11714
See files for details or call Killark.
Selector SwitchSelector Switch Key Selector Switch
1Nameplates are double sided.
For other than standard marking, refer to the special feature section of the price list.
STANDARD NAMEPLATE MARKINGS — 2 POSITION — Blank or Off-On — 3 POSITION — Blank or Hand-Off-Auto.
2Key operated selector switches are randomly keyed with keys removable in all positions.
For keyed alike or key removable in other than all positions contact factory.
For control stations with 1" conduit opening or for double gang assemblies, order cover with device and box as separate components.
FXCS TWO POSITION SELECTOR SWITCH – MAINTAINED CONTACT1
STANDARD STANDARD KEYED KEYED
COVER COMPLETE UNITS COVER COMPLETE UNITS2
WITH
HUB
(BOX & COVER) WITH (BOX & COVER)
DEVICE
SIZE
DEAD-END FEED-THRU DEVICE DEAD-END FEED-THRU
FXCS-0S2A1 1/2" FXCS-1S2A1 FXCS-4S2A1 FXCS-0K2A1 FXCS-1K2A1 FXCS-4K2A1
FXCS-0S2A1 3/4" FXCS-2S2A1 FXCS-5S2A1 FXCS-2K2A1 FXCS-5K2A1
FXCS-0S2A5 1/2" FXCS-1S2A5 FXCS-4S2A5 FXCS-0K2A5 FXCS-1K2A5 FXCS-4K2A5
FXCS-0S2A5 3/4" FXCS-2S2A5 FXCS-5S2A5 FXCS-2K2A5 FXCS-5K2A5
LEFT POSITION RIGHT POSITION
LEFT RIGHT LEFT RIGHT
CONTACT CONTACT CONTACT CONTACT
CATALOG NUMBER
FXCS TWO POSITION SELECTOR SWITCH – SPRING RETURNED1
LEFT POSITION RIGHT POSITION
LEFT RIGHT LEFT RIGHT
CONTACT CONTACT CONTACT CONTACT
CATALOG NUMBER
LEFT POSITION CENTER POSITION RIGHT POSITION
LEFT RIGHT LEFT RIGHT LEFT RIGHT
CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT
• •
• • • •
CATALOG NUMBER
TYPE OPERATION — Spring return to left from right — Maintained in left — 1 N.O. Contact — 1 N.C. Contact
STANDARD
STANDARD KEYED
KEYED
• •
• •
• • • •
• •
• •
• • • •
• •
• • • •
• •
• • • • • •
• • • •
• •
• •
••
•• ••
•• ••
•• ••
••
••
••
••
••
FXCS THREE POSITION SELECTOR SWITCH – MAINTAINED CONTACT1
STANDARD KEYED
COVER COMPLETE UNITS COVER COMPLETE UNITS2
WITH
HUB
(BOX & COVER) WITH (BOX & COVER)
DEVICE
SIZE
DEAD-END FEED-THRU DEVICE DEAD-END FEED-THRU
FXCS-0S3C4 1/2" FXCS-1S3C4 FXCS-4S3C4 FXCS-0K3C4 FXCS-1K3C4 FXCS-4K3C4
FXCS-0S3C4 3/4" FXCS-2S3C4 FXCS-5S3C4 FXCS-2K3C4 FXCS-5K3C4
FXCS-0S3C5 1/2" FXCS-1S3C5 FXCS-4S3C5 FXCS-0K3C5 FXCS-1K3C5 FXCS-4K3C5
FXCS-0S3C5 3/4" FXCS-2S3C5 FXCS-5S3C5 FXCS-2K3C5 FXCS-5K3C5
STANDARD KEYED
COVER COMPLETE UNITS COVER COMPLETE UNITS2
WITH
HUB
(BOX & COVER) WITH (BOX & COVER)
DEVICE
SIZE
DEAD-END FEED-THRU DEVICE DEAD-END FEED-THRU
FXCS-0S2L3F 1/2" FXCS-1S2L3F FXCS-4S2L3F FXCS-OK2L3F22D FXCS-1K2L3F22D FXCS-4K2L3F22D
FXCS-0S2L3F 3/4" FXCS-2S2L3F FXCS-5S2L3F FXCS-2K2L3F22D FXCS-5K2L3F22D
FXCS THREE POSITION SELECTOR SWITCH – SPRING RETURNED1
LEFT POSITION CENTER POSITION RIGHT POSITION
LEFT RIGHT LEFT RIGHT LEFT RIGHT
CONTACT CONTACT CONTACT CONTACT CONTACT CONTACT
CATALOG NUMBER
TYPE OPERATION — Spring return to center from left or right — Maintained in center — 2 N.O. Contacts
TYPE OPERATION — Spring return to center from right — Maintained center and left 2 N.O. Contacts
TYPE OPERATION — Spring return to center from left — Maintained center and right 2 N.O. Contacts
STANDARD
COVER WITH
DEVICE
FXCS-0S3M6G
FXCS-0S3M6G
FXCS-0S3L6G
FXCS-0S3L6G
FXCS-0S3R6G
FXCS-0S3R6G
HUB
SIZE
1/2”
3/4”
1/2”
3/4”
1/2”
3/4”
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
STANDARD
COMPLETE UNITS
(BOX & COVER)
DEAD-END FEED-THRU
FXCS-1S3M6G FXCS-4S3M6G
FXCS-2S3M6G FXCS-5S3M6G
FXCS-1S3L6G FXCS-4S3L6G
FXCS -2S3L6G FXCS-5S3L6G
FXCS-1S3R6G FXCS-4S3R6G
FXCS-2S3R6G FXCS-5S3R6G
KEYED
COVER WITH
DEVICE
FXCS-0K3M6G32D
FXCS-0K3L6G32D
FXCS-0K3R6G32D
KEYED
COMPLETE UNITS 2
(BOX & COVER)
DEAD-END FEED-THRU
FXCS-1K3M6G32D FXCS-4K3M6G32D
FXCS-2K3M6G32D FXCS-5K3M6G32D
FXCS-1K3L6G32D FXCS-4K3L6G32D
FXCS-2K3L6G32D FXCS-5K3L6G32D
FXCS-1K3R6G32D FXCS-4K3R6G32D
FXCS-2K3R6G32D FXCS-5K3R6G32D
C17
C
FXS SERIES CONTROLS
FACTORY SEALED TUMBLER SWITCHES AND
GROUND FAULT INTERRUPTER
FEATURES-SPECIFICATIONS
Tumbler Switches Ground Fault Interrupter
Class I, Div. I & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 7(C,D) 9(E,F,G)
For control stations with 1" conduit opening or for double gang assemblies, order cover with device
and box as separate components.
*Boxes and covers shipped separately.
†See page DE25 for additional ground fault control stations.
FXS TUMBLER SWITCHES
1Rated 15 amperes, 240/480 VAC., 3Ø; 3HP-240 VAC., 5 HP-480 VAC.
2Horsepower rated 1 HP at 120 VAC, 2 HP at 240 VAC.
CATALOG NUMBER
FXS GROUND FAULT INTERRUPTER†
Applications
FXS Tumbler Switches are suitable for
applications where making, breaking or
changing connections in an electrical
circuit is required and where conditions
of load do not exceed the switch ratings.
Applications
FXS Ground Fault Interrupters are
designed to interrupt a circuit when a
ground fault is detected on equipment
which may be handled by personnel in
hazardous locations.
Features
Test and Reset push buttons are
provided on cover assembly. Unit
should be tested monthly
Includes new GFI to meet latest
UL943 GFCI standards revisions
Exterior gasket provides NEMA 3
weatherproof protection
Ground boss for grounding in the
splice box
Color coded wiring
Captive cover bolts are made from
stainless steel
COMPLETE UNIT
COVER (BOX, COVER AND SWITCH)
WITH SWITCH DEAD-END FEED-THRU
FXS-11C FXS-41C
FXS-21C FXS-51C
FXS-12C FXS-42C
FXS-22C FXS-52C
FXS-18C FXS-48C
FXS-28C FXS-58C
FXS-13C FXS-43C
FXS-23C FXS-53C
FXS-15C FXS-45C
FXS-25C FXS-55C
FXS-16C FXS-46C
FXS-26C FXS-56C
FXS-11D FXS-41D
FXS-21D FXS-51D
FXS-12D FXS-42D
FXS-22D FXS-52D
——
FXS-1C
FXS-2C
FXS-8C
FXS-3C
FXS-5C
FXS-6C
FXS-1D
FXS-2D
FXS-4C
SWITCH SWITCH RATING
STYLE 120/277 VAC, 1Ø
1-POLE 20 A2
2-POLE 20 A2
3-POLE 1
20 A2
SPDT (Center off) 20 A2
DPDT (No off) 20 A2
1-POLE 30 A2
2-POLE 30 A2
4-WAY 20 A2
3-WAY/
SPDT (No off)
HUB
SIZE
DEAD
END
FEED
THRU
1/2"
3/4"
1"
1/2"
3/4"
1"
CATALOG NUMBER
COMPLETE UNIT COVER ASSEMBLY BACK BOX*
FXS-GFI-1020 FXS-GFIO3 FXB-1
FXS-GFI-2020 FXS-GFIO3 FXB-2
FXS-GFI-3020 FXS-GFIO3 FXB-3
FXS-GFI-1120 FXS-GFIO3 FXB-4
FXS-GFI-2120 FXS-GFIO3 FXB-5
FXS-GFI-3120 FXS-GFIO3 FXB-6
Listed - File E80595
Certified - File LR61895
See files for details or call Killark.
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
Listed - File E53360 and/or Ffile E10501
Certified - File LR11714
See files for details or call Killark.
Electrical Rating
GFI units are rated at 20A, 120 VAC,
60HZ. Class A.
4-6 miliamp trip setting
Trip Time-UL Curve
FXS GROUND FAULT INTERRUPTER WITH LED LAMP
CATALOG NUMBER FOR COVER ASSEMBLY FXS-GFIO3PL
* Order FXB back box as seperate item.
For GFI Protection with
receptacle, See page PR26
C18 XCS/XS/SWB SERIES CONTROLS
CONTROL STATIONS EXTERNAL SEALING REQUIRED
FEATURES-SPECIFICATIONS
Applications
Hazardous locations due to the pres-
ence of flammable gases or vapors,
combustible dusts or easily ignitable
fiber or flyings
Installations at petroleum refineries,
chemical and petrochemical plants
and other processing or storage facili-
ties where similar hazards exist
Use in conjunction with magnetic
starters or contactors for remote control
of motors
Features
Device bodies and covers are cast cop-
perfree Aluminum alloy and provide a
wide assortment for custom assemblies
Cast conduit hubs 1/2", 3/4" and 1"
either dead end or feed thru standard
in both single and two gang, SWB-1
thru SWB-12 device bodies
SWB-13 thru SWB-38 are designed for
custom drilled and tapped conduit
openings on all four sides and the back
Ground flange joint between bolted
cover and box provide required flame
path
Push button, selector switches and pilot
light operator bodies are copper-free
aluminum
Operating shaft in both push buttons
and selector switches are stainless
steel
Open space between gangs for easy
wiring from one cover to another
Listed - File E53360
Certified - File LR11714, LR11712
See files for details or call Killark.
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
Miniature and standard size push but-
tons. (Miniature 3/4" overall diameter,
standard 1-3/8" overall diameter.)
Contact blocks are rated heavy duty,
600 VAC max
Internal ground screw
Electrical Rating
Push button stations, selector switches
heavy duty 600 VAC max.
Pilot lights 120 VAC.
XCS Special Assemblies
To order XCS cover assemblies for use
with multi-gang or 1" hub type SWB Series
splice boxes, simply order as follows:
Example: XCS-0B1 Cover Assembly
SWB-6
Splice box with
1" feed thru hubs
Example: XCS-0B1 Cover Assembly
XCS-0B24RL
Cover Assembly
SWB-12 Double gang
splice box
NOTE: Splice boxes and cover assemblies are
packaged in separate cartons.
CURRENT 125 VAC 250 VAC
INRUSH .55 .275
BREAKING .55 . 2 7 5
CARRYING 2. 5 0 2.50
DC RATINGS (MAX. AMPS)
CURRENT 120 VAC 240 VAC 480 VAC 600 VAC
INRUSH 60 30 15 12
BREAKING 631.5 1.2
CARRYING 10 10 10 10
CONTACT BLOCK RATINGS
CATALOG
SUFFIX DESCRIPTION
MODIFICATIONS
AL Pilot light lens-amber
CL Pilot light lens-clear
GL Pilot light lens-green
RL Pilot light lens-red
T2 1Pilot light transformer —
220/110VAC
T4 1Pilot light transformer —
440/110VAC
MR Mushroom head push button
(red)
LO Push button lockout2
LOP Selector switch
padlock-lockout
SU1 Stainless steel cover screws
1One transformer required for each pilot light.
Deep device bodies required for all
except single pilot light units when
transformers are used.
2Push button lockout must be factory installed.
LED lamps available. See page C39.
C19
C
SWB SERIES CONTROLS
DEVICE FODIES FOR USE WITH XCS/XS/XT COVER ASSEMBLIES
FEATURES-SPECIFICATIONS
2-3/8"(60)
2-3/8"(60)
2-3/8"(60)
2-3/8"(60)
2-3/8"(60)
2-3/8"(60)
2-1/2"(64)
2-1/2"(64)
2-1/2"(64)
2-1/2"(64)
2-1/2"(64)
2-1/2"(64)
2-3/8"(60)
2-3/8"(60)
2-1/8"(54)
5-3/4"(146)
9-3/16"(233)
12-11/16"(322)
16-3/16"(411)
9-3/16"(233)
12-3/4"(324)
16-1/4"(413)
16-1/4"(413)
2-3/8"(60)
2-3/8"(60)
2-3/8"(60)
5-3/8"(137)
5-3/8"(137)
5-3/8"(137)
5-3/8"(137)
5-3/8"(137)
5-3/8"(137)
5-3/8"(137)
5-3/8"(137)
5-3/8"(137)
5-3/8"(137)
5-3/8"(137)
5-3/8"(137)
6-1/8"(156)
6-1/8"(156)
11-3/8"(289)
6"(152)
6"(152)
6"(152)
6"(152)
11-1/8"(283)
11-3/16"(284)
11-5/16"(287)
11-5/16"(287)
6-1/8"(156)
6-1/8"(156)
6-1/8"(156)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/4"(57)
2-1/2"(64)
3-5/16"(84)
2-1/2"(64)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3-5/16"(84)
3"(76)
3"(76)
3"(76)
3"(76)
3"(76)
3"(76)
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
6-1/2"(165)
3-5/8"(92)
3-5/8"(92)
3-5/8"(92)
7-1/8"(181)
10-5/8"(270)
14-1/8"(359)
17-5/8"(448)
10-5/8"(270)
14-1/8"(359)
17-3/4"(451)
17-3/4"(451)
3-5/8" (92)
3-5/8"(92)
3-5/8"(92)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-7/8”(149)
5-7/8"(149)
5-7/8"(149)
5-7/8"(149)
5-1/4"(133)
5-1/4"(133)
10-3/8"(264)
5-1/4"(133)
5-1/4"(133)
5-1/4"(133)
5-1/4"(133)
12"(305)
10-3/8”(264)
12"(305)
17-1/8"(435)
5-1/4"(133)
5-1/4"(133)
5-1/4"(133)
Listed - File E53360
Certified - LR11712
See files for details or call Killark.
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
CATALOG HUB EXTERNAL MOUNTING
NUMBER SIZE LENGTH WIDTH DEPTH VERTICAL HORIZONTAL
SWB-1 1/2"
SWB-2 3/4"
SWB-3 1"
SWB-4 1/2"
SWB-5 3/4"
SWB-6 1"
SWB-7 1/2"
SWB-8 3/4"
SWB-9 1"
SWB-10 1/2"
SWB-11 3/4"
SWB-12 1"
SWB-13 1
SWB-14 2
SWB-17 1
SWB-18 2
SWB-19 2
SWB-20 2
SWB-21 2
SWB-32 2
SWB-33 2
SWB-34 2
SWB-38 2
SWB-42 3/4"
SWB-45 3/4"
SWB-49 3/4"
1Maximum size drilled and tapped opening 1" — Shallow device bodies.
2Maximum size drilled and tapped opening 1-1/2" — Deep device bodies.
3SWB-1 thru SWB-12 Boxes have cast in conduit hubs. Additional conduit openings can not be included.
Use SWB-13-14 or 18 for custom conduit requirements. See following page for custom conduit information.
SWB-13 through SWB-38 boxes are blank
without conduit openings and can be
factory or field installed. See following
page for custom conduit information.
SWB DEVICE BODIES AND DIMENSIONS
SWB-13-14 SWB-18
SWB-19
SWB-20
SWB-17
SWB-33
SWB-34 SWB-38
Dead End
SWB-1-2-3 3
Feed Thru
SWB-4-5-6 3
Dead End
SWB-7-8-9 3
Feed Thru
SWB-10-11-12 3
SWB-32
SWB-42
(3/4" Dead End)
SWB-45
(3/4" Feed Thru)
SWB-48
(Two 1/2"on Bottom)
SWB-49
(Two 3/4"on Bottom)
SWB-21
C20 SWB SERIES CONTROLS
CONDUIT OPENING DATA
FEATURES-SPECIFICATIONS
To specify conduit openings select the
letter on these sketches which indicates
the position desired. All conduit open-
ings will be evenly spaced and located
in the area indicated on the location
chart. When they are to be more accu-
rately located, submit a sketch with
spacing dimensions. Specific conduit
openings must be located dimensional-
ly from box centerlines to conduit cen-
terlines and from outside back surface
of box to conduit centerline.
Ordering Instructions:
(1) Select the letter on location chart
which indicates conduit opening
position desired.
(2) Select symbol number from chart
which indicates conduit opening
type and size.
(3) Combine the conduit location letter,
size and type number, and add as a
suffix to SWB box catalog number.
Example: SWB-18-C1-J1-P1-V1
Conduit Opening Location Charts
11
2
1 2 1 2 3
1 2 3
4 5 6
1 2 3 4
1 2 3 4
5 6 7 8
12345 12345
6 7 8 9 10
12345
6 7 8 9 10
11 12 13 14 15
A BCD E
ABCDE
ABCDE
ABCDE
ABDE
ACE
RPN
ACE
AC E
RPN RPN
RQPON R Q P O N
R Q O N N O P Q R
R QPO N
J
JX
T
X
T
X
T
X
T
X
T
L
G
L
G
L
G
L
G
L
G
V
VJ
J
J
C
P
C
P
J
V
V
VV
SWB-13-14 SWB-17 SWB-18 SWB-19 SWB-20
SWB-21 SWB-32 SWB-33 SWB-34 SWB-38
SIZE FORM 1/2" 3/4" 1" 1-1/4" 1-1/2"
1MIN 1-3/16"(46) ——
2PRE 1-3/8"(35) ——
3GU 1-5/8"(41) ——
1MIN 1-3/8"(35) 1-1/2"(38) ——
2PRE 1-1/2"(38) 1-5/8"(41) ——
3GU 1-3/4"(44) 1-13/16"(46) ——
1MIN 1-1/2"(38) 1-3/4"(44) 1-13/16"(46) ——
2PRE 1-3/4"(44) 1-7/8"(48) 2"(51) ——
3GU 1-7/8"(48) 2"(51) 2-1/8"(54) ——
1MIN 1-11/16"(43) 1-15/16"(49) 2-1/16"(52) 2-5/16"(59)
2PRE 1-15/16"(49) 2-1/16"(52) 2-1/4"(57) 2-1/2"(64)
3GU 2-1/16"(52) 2-1/4"(57) 2-5/16"(59) 2-1/2"(64)
1MIN 1-15/16"(49) 2-1/16"(52) 2-3/16"(56) 2-1/2"(64) 2-5/8"(67)
2PRE 2-1/8"(54) 2-1/4"(57) 2-3/8"(60) 2-5/8"(67) 2-3/4"(70)
3GU 2-3/16"(56) 2-9/32"(58) 7/16"(11) 2-5/8"(67) 2-3/4"(70)
1-1/8"(29) 1-3/8"(35) 1-11/16"(43) 2-3/16"(56) 2-7/16"(62)
1"(25) 1-1/4"(32) 1-1/2"(38) 1-7/8"(48) 2-1/8"(54)
7/8"(22) 1-1/16"(27) 1-3/8"(35) 1-11/16"(43) 1-15/16"(49)
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
1"
1"
1"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/2"
1-1/2"
Locknut Bushing Conduit
Locknut Bushing Conduit
Locknut Bushing Conduit
1Minimum spacing required to provide clearance over locknuts and bushings.
2Preferred—more liberal spacings between centers of conduits to be used whenever possible.
3GU—spacing required for GU Series unions.
4Union hubs are supplied by using a drilled and tapped opening with GUM Series Union.
† Consult factory for special or additional conduit sizes, locations, and combinations
required but not illustrated.
MINIMUM HUB CENTERS FOR DRILLED AND TAPPED AND UNION HUBS
CONDUIT OPENINGS
CONDUIT DRILLED
SIZE AND TAPPED UNION4
1/2" 1 11
3/4" 2 12
1" 3 13
1-1/4" 4 14
1-1/2" 5 15
SYMBOL NUMBERS
C21
C
XCS SERIES CONTROLS
COVER ASSEMBLIES CONTROL STATIONS
FEATURES-SPECIFICATIONS
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM BUTTON NAMEPLATE
COVER WITH DEVICE DEAD-END FEED-THRU SIZE COLOR2MARKING1
XCS-0B1 XCS-1B1 XCS-4B1 1/2" Green Start
XCS-2B1 XCS-5B1 3/4"
XCS-0B2 XCS-1B2 XCS-4B2 1/2" Red Stop
XCS-2B2 XCS-5B2 3/4"
XCS-0B3 XCS-1B3 XCS-4B3 1/2" Black Specify
XCS-2B3 XCS-5B3 3/4"
XCS MOMENTARY CONTACT SINGLE PUSH BUTTON
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM BUTTON NAMEPLATE
COVER WITH DEVICE DEAD-END FEED-THRU SIZE COLOR2MARKING1
XCS-0B4 XCS-1B4 XCS-4B4 1/2" Green-Red Start/Stop
XCS-2B4 XCS-5B4 3/4"
XCS-0B4-U XCS-1B4-U XCS-4B4-U 1/2" Green-Red Start/Stop
XCS-2B4-U XCS-5B4-U 3/4"
XCS-0B5 XCS-1B5 XCS-4B5 1/2" Green-Green Start/Start
XCS-2B5 XCS-5B5 3/4"
XCS-0B7 XCS-1B7 XCS-4B7 1/2" Black-Black Specify
XCS-2B7 XCS-5B7 3/4"
XCS MOMENTARY CONTACT DOUBLE PUSH BUTTON
Listed - File E53360
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
1For other than standard marking, refer to the special feature section of price list.
2Lens colors other than listed may be specified by changing lens color suffix. See modifications page C18.
For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM BUTTON NAMEPLATE
COVER WITH DEVICE DEAD-END FEED-THRU SIZE COLOR2MARKING1
XCS-0A8 XCS-1A8 XCS-4A8 1/2" Green-Red Start/Stop
XCS-2A8 XCS-5A8 3/4" Black Specify
XCS-0A9 XCS-1A9 XCS-4A9 1/2" Black Specify
XCS-2A9 XCS-5A9 3/4"
XCS MOMENTARY CONTACT THREE MINI PUSH BUTTONS
Single
Push Button
Double
Push Button
Three
Mini-Push Button
• •
• •
• •
• •
• • • •
• •
• • • •
• •
• • • •
• •
• • • •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• • • •
CATALOG NUMBER (COVER WITH DEVICE) DIAGRAM BUTTON COLOR NAMEPLATE MARKING
XCS-OMMG3 GREEN
XCS-OMMR3 RED 3
XCS-OMMK3 BLACK
XCS MAINTAINED CONTACT PUSH PULL MUSHROOM PUSH BUTTON4
3Three nameplates supplied (Start/Stop, Blank, Emergency Stop) with XCS maintained push button.
4Operation - when push button is depressed and contact activated, operator will remain in depressed
position until pulled out in normal position.
Push-Pull
Mushroom Maintained
Push Button
• • • •
C22 XCS SERIES CONTROLS
COVER ASSEMBLIES CONTROL STATIONS
FEATURES-SPECIFICATIONS
Listed - File E53360
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
CATALOG NUMBER NAMEPLATE
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM BUTTON LENS MARKING1
COVER WITH DEVICE DEAD-END FEED-THRU SIZE COLOR COLOR BUTTON LENS
XCS-0A15
XCS-1A15 XCS-4A15 1/2" Red
Red
Stop
Specify
XCS-2A15 XCS-5A15 3/4" 120 VAC Green Start
XCS MOMENTARY CONTACT TWO MINI PUSH BUTTONS AND PILOT LIGHT4
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM LAMP LENS NAMEPLATE
COVER WITH DEVICE DEAD-END FEED-THRU SIZE VOLTS COLOR2MARKING1
XCS-0B30CL XCS-1B30CL XCS-4B30CL 1/2" 120V Clear Specify
XCS-2B30CL XCS-5B30CL 3/4"
XCS-0B30GL XCS-1B30GL XCS-4B30GL 1/2" 120V Green Specify
XCS-2B30GL XCS-5B30GL 3/4"
XCS-0B30RL XCS-1B30RL XCS-4B30RL 1/2" 120V Red Specify
XCS-2B30RL XCS-5B30RL 3/4"
XCS-0B30RL-GL XCS-1B30RL-GL XCS-4B30RL-GL 1/2" 120V Red/Green Specify
XCS-2B30RL-GL XCS-5B30RL-GL 3/4"
XCS DOUBLE PILOT LIGHT4
1For other than standard marking, refer to the special feature section of price list.
2Lens color suffix listed in modifications page C18. Unless different lens colors are specified by proper suffix catalog number, red lens will be provided.
3Pilot light transformers also listed in modifications. Add suffix to cover assembly catalog number.
4Pilot light transformers will not fit in these assemblies. When transformer is desired, use SWB-14, indicating conduit openings required from chart on
page C20 of this section. See page C18 for required transformer suffix. One transformer required for each lamp.
For control stations with 1" conduit openings or for multi-gang assemblies, order cover and box as separate components.
CATALOG NUMBER NAMEPLATE
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM BUTTON LENS MARKING1
COVER WITH DEVICE DEAD-END FEED-THRU SIZE COLOR COLOR BUTTON LENS
XCS-0B13-C XCS-1B13-C XCS-4B13-C 1/2" Red Red Stop Specify
XCS-2B13-C XCS-5B13-C 3/4"
XCS-0B13-O XCS-1B13-O XCS-4B13-O 1/2" Green Red Start Specify
XCS-2B13-O XCS-5B13-O 3/4"
XCS-0B13-U XCS-1B13-U XCS-4B13-U 1/2" Black Red Specify Specify
XCS-2B13-U XCS-5B13-U 3/4"
XCS MOMENTARY CONTACT PUSH BUTTON AND PILOT LIGHT4
CATALOG NUMBER
COMPLETE UNITS (BOX & COVER) HUB DIAGRAM LAMP LENS NAMEPLATE
COVER WITH DEVICE DEAD-END FEED-THRU SIZE VOLTS COLOR2MARKING1
XCS-0B24CL XCS-1B24CL XCS-4B24CL 1/2" 120V Clear Specify
XCS-2B24CL XCS-5B24CL 3/4"
XCS-0B24GL XCS-1B24GL XCS-4B24GL 1/2" 120V Green Specify
XCS-2B24GL XCS-5B24GL 3/4"
XCS-0B24RL XCS-1B24RL XCS-4B24RL 1/2" 120V Red Specify
XCS-2B24RL XCS-5B24RL 3/4"
XCS PILOT LIGHT3
Pilot Light
Two Mini Push Buttons
Double
Pilot Light
Pilot Light
Pilot Light
Push Button
• •
• •
• •
• •
• •
2
2
C23
C
XCS SERIES CONTROLS
COVER ASSEMBLIES CONTROL STATIONS
FEATURES-SPECIFICATIONS
Listed - File E53360
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7 (C,D) 9(E,F,G)
CATALOG NUMBER TWO POSITION DIAGRAM
LEFT POSITION RIGHT POSITION
COVER WITH COMPLETE UNITS (BOX & COVER)
HUB
LEFT RIGHT LEFT RIGHT
NAMEPLATE
DEVICE DEAD-END FEED-THRU
SIZE
BLOCKS BLOCKS BLOCKS BLOCKS
MARKING
XCS-0S2A1 XCS-1S2A1 XCS-4S2A1 1/2" OFF/ON
XCS-2S2A1 XCS-5S2A1 3/4"
XCS-0S2A52XCS-42S2A5 XCS-45S2A5 3/4" OFF/ON
XCS TWO POSITION SELECTOR SWITCH (MAINTAINED)*
CATALOG NUMBER THREE POSITION DIAGRAM
LEFT POSITION CENTER POSITION RIGHT POSITION
COVER WITH COMPLETE UNITS (BOX & COVER)
HUB
LEFT RIGHT LEFT RIGHT LEFT RIGHT
NAMEPLATE
DEVICE DEAD-END FEED-THRU
SIZE
BLOCKS BLOCKS BLOCKS BLOCKS BLOCKS BLOCKS
MARKING
XCS-0S3C4 XCS-1S3C4 XCS-4S3C4 1/2" HOA
XCS-2S3C4 XCS-5S3C4 3/4"
XCS-0S3C52XCS-42S3C5 XCS-45S3C5 3/4" HOA
XCS THREE POSITION SELECTOR SWITCH (MAINTAINED)*
• • • • • •
1For other than standard marking, refer to the special feature section of the price list.
2These sub-assemblies require deep style box SWB-14 or SWB-18 through SWB-49.
For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
CATALOG NUMBER TWO POSITION DIAGRAM
LEFT POSITION RIGHT POSITION
COVER WITH COMPLETE UNITS (BOX & COVER)
HUB
LEFT RIGHT LEFT RIGHT
NAMEPLATE
DEVICE DEAD-END FEED-THRU
SIZE
BLOCKS BLOCKS BLOCKS BLOCKS
MARKING
XCS-0K2A1D XCS-1K2A1D XCS-4K2A1D 1/2" OFF/ON
XCS-2K2A1D XCS-5K2A1D 3/4"
XCS-0K2A5D2XCS-42K2A5D XCS-45K2A5D 3/4" OFF/ON
XCS TWO POSITION KEY OPERATED SELECTOR SWITCH (MAINTAINED)*
• •
CATALOG NUMBER THREE POSITION DIAGRAM
LEFT POSITION CENTER POSITION RIGHT POSITION
COVER WITH COMPLETE UNITS (BOX & COVER)
HUB
LEFT RIGHT LEFT RIGHT LEFT RIGHT
NAMEPLATE
DEVICE DEAD-END FEED-THRU
SIZE
BLOCKS BLOCKS BLOCKS BLOCKS BLOCKS BLOCKS
MARKING
XCS-0K3C4D XCS-1K3C4D XCS-4K3C4D 1/2" HOA
XCS-2K3C4D XCS-5K3C4D 3/4"
XCS-0K3C5D2XCS-42K3C5D XCS-45K3C5D 3/4" HOA
XCS THREE POSITION KEY OPERATED SELECTOR SWITCH (MAINTAINED)*
1For other than standard marking, refer to the special feature section of the price list.
2These sub-assemblies require deep style box SWB-14 or SWB-18 through SWB-49.
For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
* Key removal in all positions for 2 & 3 position key operated selectors. Consult factory for variations.
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• • • • • •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
Key Operated
Selector Switch
• •
• •
• •
• •
• •
• •
• • • •
1
1
C24 XCS SERIES CONTROLS
COVER ASSEMBLIES CONTROL STATIONS
FEATURES-SPECIFICATIONS
XCS SPRING RETURN SELECTOR SWITCH
Three Position Spring Return to Center From Left, Maintain in Right
CATALOG NUMBER THREE POSITION DIAGRAM
COMPLETE UNITS (BOX & COVER)
DEAD-END
XCS-0S3R6G XCS-42S3R6G XCS-45S3R6G 3/4"
LEFT POSITION CENTER POSITION RIGHT POSITION
FEED-THRU
COVER WITH
DEVICE1
HUB
SIZE
XCS SPRING RETURN SELECTOR SWITCH
Three Position Spring Return to Center From Right, Maintain in Left
CATALOG NUMBER THREE POSITION DIAGRAM
COMPLETE UNITS (BOX & COVER)
DEAD-END
XCS-0S3L6G XCS-42S3L6G XCS-45S3L6G 3/4"
LEFT POSITION CENTER POSITION RIGHT POSITION
FEED-THRU
COVER WITH
DEVICE1
HUB
SIZE
XCS SPRING RETURN SELECTOR SWITCH
Three Position Spring Return to Center From Right and Left
CATALOG NUMBER THREE POSITION DIAGRAM
COMPLETE UNITS (BOX & COVER)
DEAD-END
XCS-0S3M6G XCS-42S3M6G XCS-45S3M6G 3/4"
LEFT POSITION CENTER POSITION RIGHT POSITION
FEED-THRU
COVER WITH
DEVICE1
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
HUB
SIZE
• • • •
XCS SPRING RETURN SELECTOR SWITCH
Two Position Spring Return to Left
CATALOG NUMBER TWO POSITION DIAGRAM
COMPLETE UNITS (BOX & COVER)
DEAD-END
XCS-0S2L3F XCS-42S2L3F XCS-45S2L3F 3/4"
LEFT POSITION RIGHT POSITION
FEED-THRU
COVER WITH
DEVICE1
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
HUB
SIZE
1All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49.
For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box as separate components.
Selector Switch
• • • •
• • • • • • • • • • • •
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
• • • • • • • • • • • •
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
• • • • • • • • • • • •
Listed - File E53360
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7 (C,D) 9(E,F,G)
C25
C
XCS SERIES CONTROLS
COVER ASSEMBLIES CONTROL STATIONS
FEATURES-SPECIFICATIONS
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH1
Three Position Spring Return to Center From Left, Maintain in Right
CATALOG NUMBER THREE POSITION DIAGRAM
COMPLETE UNITS (BOX & COVER)
DEAD-END
XCS-0K3R6G32D XCS-42K3R6G32D XCS-45K3R6G32D 3/4"
LEFT POSITION CENTER POSITION RIGHT POSITION
FEED-THRU
COVER WITH
DEVICE2
HUB
SIZE
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH1
Three Position Spring Return to Center From Right, Maintain in Left
CATALOG NUMBER THREE POSITION DIAGRAM
COMPLETE UNITS (BOX & COVER)
DEAD-END
XCS-0K3L6G32D XCS-42K3L6G32D XCS-45K3L6G32D 3/4"
LEFT POSITION CENTER POSITION RIGHT POSITION
FEED-THRU
COVER WITH
DEVICE2
HUB
SIZE
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH1
Three Position Spring Return to Center From Right and Left
CATALOG NUMBER THREE POSITION DIAGRAM
COMPLETE UNITS (BOX & COVER)
DEAD-END
XCS-0K3M6G32D XCS-42K3M6G32D XCS-45K3M6G32D 3/4"
LEFT POSITION CENTER POSITION RIGHT POSITION
FEED-THRU
COVER WITH
DEVICE2
HUB
SIZE
XCS KEY OPERATED SPRING RETURN SELECTOR SWITCH1
Two Position Spring Return to Left
CATALOG NUMBER TWO POSITION DIAGRAM
COMPLETE UNITS (BOX & COVER)
DEAD-END
XCS-0K2L3F22D XCS-42K2L3F22D XCS-45K2L3F22D 3/4"
LEFT POSITION RIGHT POSITION
FEED-THRU
COVER WITH
DEVICE2
HUB
SIZE
1All key operators are furnished keyed different.
If keyed alike is required substitute letter “A” for “D” at end of catalog number.
Keys are removable in left position selectors and in center position for 3 position selectors.
For key removable in all positions change “22” in 2 position to “20” and “32” in 3 position to “30”.
2All spring return assemblies must be installed on deep style box SWB-14 or SWB-18 through SWB-49.
For control stations with 1" conduit openings or for multi-gang assemblies, order cover with devices and box
as separate components.
Key Operated
• • • •
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
• • • •
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
• • • • • • • • • • • •
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
• • • • • • • • • • • •
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
LEFT
BLOCK
RIGHT
BLOCK
• • • • • • • • • • • •
Listed - File E53360
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7 (C,D) 9(E,F,G)
C26 SEAL X/XCS SERIES CONTROLS
BLANK ACCESSORIES/REPLACEMENT PARTS
Hole Plug Dust/Weather
Cap
Miniature
Push Button
CAT. NO. DESCRIPTION
X-10 Blank cover
X-60 Cover with (1) 3/4" NPSM Hole1
X-64 Cover with (2) 3/4" NPSM Holes1 2
X BLANK AND SPECIAL COVERS
1For “G” series short operators.
2When X-64 cover is used, one operator
must be a pilot light due to electrical clear-
ances. *1-1/2” diameter
STANDARD PUSH BUTTON ASSEMBLY MINIATURE PUSH BUTTON ASSEMBLY
(1-3/8” DIAMETER) (3/4” DIAMETER)
X-10
Blank Cover
LOCKOUT FOR MAINTAINED
PUSH BUTTON COVERS
XCS-OMMR3
FXCS-OMMR3
CATALOG NUMBER GOMLOCK
CATALOG NUMBER
PUSH BUTTON1SELECTOR HOLE DUST/WEATHER CAP
LOCKOUT LOCKOUT1PLUG1RED GREEN BLACK
DESCRIPTION
XLOB G0-567-LOK XOBP XDBR XDBG XDBB Standard operator
XLOA XOAP ——Miniature operator
ACCESSORIES
CATALOG NUMBER DESCRIPTION
XCSNPPB XCS/FXCS full size (standard) push button
XCSNPPBM XCS/FXCS miniature push button
XCSNPPL XCS/FXCS pilot light
XCSNPSS2 XCS/FXCS 2 position selector switch
XCSNPSS3 XCS/FXCS 3 position selector switch
XCS REPLACEMENT BLANK NAMEPLATES
1Replacement only by qualified person. Operator is staked into position at factory.
Removal may damage operator or cover threads.
Miniature
Lockout
Selector
Lockout
Standard
Lockout GOM Lockout
Standard
Push Button
(Mushroom)
RED
XO1BR
XO3BR
XO5BR
GREEN
XO1BG
XO3BG
BLACK
XO1BK
XO3BK
CATALOG NUMBER
RED
XO1AR
XO3AR
GREEN
XO1AG
XO3AG
BLACK
XO1AK
XO3AK
SHROUD
Full
Half
Mushroom*
XCS PILOT LIGHT OPERATOR ASSEMBLY1
CATALOG NUMBER
RED GREEN CLEAR AMBER
XO21BR XO21BG XO21BC XO21BA Standard
Pilot Light
SHROUD
C27
C
SEAL X/XCS SERIES CONTROLS
ACCESSORIES/REPLACEMENT PARTS
Contact Block
Incandescent
Filament Lamp
LED Lamp
Incandescent
Filament Lamp
LED Lamp
CAT. NO. VOLT COLOR
0460051B 120V AC/DC CLEAR
0460414B 24V AC/DC CLEAR
INCANDESCENT LAMP
CANDELABRA SCREW BASE
CAT. NO. VOLT COLOR
XCSLED-R110 120 VAC RED
XCSLED-G110 120 VAC GREEN
XCSLED-A110 120 VAC AMBER
XCS-FXCS LED LAMPS
CAT. NO. DESCRIPTION
GO-8672-BJK 1 N.O.
GO-8672-BJJ 1 N.O.
GO-8672-BJH 1 N.O. Early Make
GO-8672-BJE 1 N.C. Late Make
STANDARD CONTACT BLOCKS
CAT. NO. DESCRIPTION
YOWE-OT2B 1 N.O.
YOWE-OT2D 1 N.C.
CONTACT BLOCKS FOR XCS SERIES
CATALOG NUMBERS ENDING WITH
B4-U, B7, A8 OR A9
CAT. NO. DESCRIPTION
GO-8672-PTCH (1) N.O. (1) N.C.
CONTACT BLOCK FOR FXCS SERIES
CATALOG NUMBERS ENDING WITH
B-13U
CAT. NO. DESCRIPTION
GO-8672-PTCC (2) N.O. (2) N.C.
CONTACT BLOCK FOR FXCS SERIES
CATALOG NUMBERS ENDING WITH
B4-U, B7, A5, C5
CAT. NO. LAMP TYPE VOLTS AC/DC COLOR
YOSY24MB FILAMENT 24 CLEAR
YOSY120MB FILAMENT 120 CLEAR
GOLED-A110 LED 110 AMBER
GOLED-G110 LED 110 GREEN
GOLED-R110 LED 110 RED
GOLED-A24 LED 24 AMBER
GOLED-G24 LED 24 GREEN
GOLED-R24 LED 24 RED
XCS-FXCS LAMPS
C28
FEATURES-SPECIFICATIONS
XS SERIES CONTROLS
TUMBLER SWITCH
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
Applications
Used where making, breaking, or
changing connections in an electric cir-
cuit are required.
Features
XS Series are front lever rotary operat-
ed switch assemblies with standard
provisions for padlocking in either “ON”
or “OFF” position. The lever is connect-
ed to a threaded stainless steel shaft
which passes through the cover.
XS TUMBLER SWITCH
1Rated 15 amperes, 240/480 VAC., 3Ø: 3HP-240 VAC., 5 HP-480 VAC.
2Horsepower rated 1 HP at 120VAC, 2 HP at 240VAC.
SWITCH SWITCH RATING
STYLE 120/277 VAC, 1Ø
1-POLE 20A2
2-POLE 20A2
3-POLE 1
3-WAY/ 20A2
SPDT No center off
SPDT 20A2
Center off
DPDT 20A2
No center off
DPDT 20A2
Center off
1-POLE 30A2
2-POLE 30A2
4-WAY 20A2
CATALOG NUMBER
COVER COMPLETE UNITS
WITH WITHOUT HUB (BOX, COVER AND SWITCH)
DEVICE DEVICE SIZE DEAD-END FEED-THRU
XS-1C XNS-1C 1/2" XS-11C XS-41C
3/4" XS-21C XS-51C
XS-2C XNS-2C 1/2" XS-12C XS-42C
3/4" XS-22C XS-52C
XS-8C XNS-8C 1/2" XS-18C XS-48C
3/4" XS-28C XS-58C
XS-3C XNS-3C 1/2" XS-13C XS-43C
3/4" XS-23C XS-53C
XS-5C XNS-5C 1/2" XS-15C XS-45C
3/4" XS-25C XS-55C
XS-6C XNS-6C 1/2" XS-16C XS-46C
3/4" XS-26C XS-56C
XS-7C XNS-7C 1/2" XS-17C XS-47C
3/4" XS-27C XS-57C
XS-1D XNS-1D 1/2" XS-11D XS-41D
3/4" XS-21D XS-51D
XS-2D XNS-2D 1/2" XS-12D XS-42D
3/4" XS-22D XS-52D
XS-4C — ——
XS-3C
Certified - File LR11712
See files for details or call Killark.
Listed - FILE E53360
File OP7A5.AE
FM
APPROVED
C29
FEATURES-SPECIFICATIONS
C
XAL/XAS SERIES CONTROLS
FIRE ALARM STATIONS
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
XAS: Breaking glass with hammer pro-
vided activates alarm. Reset by replac-
ing glass.
Replacement glass catalog number
YOKK-15214.
Replacement hammer and chain
KIT-232.
XAS Series:
XAL-53
Dimensions
XAS-53
AC DC
CONTINUOUS CONTINUOUS
VOLTS MAKE VA BREAK VA CARRYING VOLTS MAKE CARRYING
AMPERES AMPERES AMPERES BREAK AMPERES
120 60 7200 6 720 10 125 1.1 2.5
240 30 7200 3 720 10 250 0.55 2.5
480 15 7200 1.5 720 10 600 0.2 2.5
600 12 7200 1.2 720 10 —— —
CONTACT BLOCK RATING
XAL FIRE ALARM STATION
Applications
Hazardous areas due to the pres-
ence of flammable gases or vapors,
combustible dusts or easily ignitable
fibers or flyings
Installation at petroleum refineries,
chemical and petrochemical plants,
storage areas, and other processing
facilities where hazardous sub-
stances are handled or stored
Areas where emergency control of
fire alarm or signal circuits is required
Features
Enclosure is made of copper free alu-
minum alloy
Conduit openings are 3/4" NPT feed
through
Red, textured powder epoxy paint
finish is standard on box and cover
and provides high visibility for alarm
station
XAL-458 has (2) normally open and
(2) normally closed contacts.
Bilingual nameplates included per
CSA requirement
Internal ground screw is standard
Listed - File E50498
Certified - File LR31085
Listed - CE69
Listed - California State Fire Marshall
#7150-1439:100
Operation
XAL: The alarm station is activated by
lifting the front cover and pulling down
ring. This quick, easy to use two-step
process prevents unintentional opera-
tion. Operator is reset by depressing
shaft and returning plate to original
position.
XAL Series:
Listed - File E50498
Certified - File LR31085
See files for details or call Killark.
Note: On XAL-458 the overall depth is 5-9/16”
CATALOG NUMBER OPERATION TYPE CONTACT BLOCKS
XAL-53 Pull ring (1) NO/NC
XAL-458 Pull ring (2) NO/NC
XAS-53 Break glass (1) NO/NC
XAL
Pull Ring
XAS
Break Glass
C30
Short Style
DB/SWB/GCS Enclosures. Assemblies
with wall thickness up to 1/2" thick.
Long Style
All B7E/XJB Enclosures. EXB (see page
E12) enclosures with cover thickness
up to 1-1/2” thick.
Extended Style
EXB larger size enclosures (see page
E12) with cover thickness up to 2-1/2”
thick.
Killark long and extended push but-
tons, selector switches, reset and
G SERIES CONTROLS
CUSTOM CONTROL PANEL OPERATORS INTRODUCTION
FEATURES-SPECIFICATIONS
CURRENT 120 VAC 240 VAC 480 VAC 600 VAC 125 VDC 250 VDC
Inrush 60 30 15 12 .55 .275
Breaking 631.5 1.2 .55 .275
Carrying 10 10 10 10 2.50 2.50
CONTACT BLOCK RATINGS
Note: Contact blocks can be stacked four deep maximum.
AREA CLASSIFICATION CHART FOR OPERATORS
1Class II Div. 1 & 2 Group EFG NEMA 9EFG
2Class I Div. 1 & 2 Group CD, Class II Div. 1 & 2 Group EFG, Class III NEMA 7CD, 9EFG
3Class I Div. 1 & 2 Group BCD, Class II Div. 1 & 2 Group EFG, Class III NEMA 3, 4, 7BCD, 9EFG
4Class I Div. 1 & 2 Group BCD, Class II Div. 1 & 2 Group EFG, Class III NEMA 3, 4, 4X, 7BCD, 9EFG
5Class I Div. 1 & 2 Group CD, Class II Div. 1 & 2 Group EFG, Class III NEMA 3, 4, 7CD, 9EFG
Recommended Operator SelectionApplications
G Series custom control panel opera-
tors are designed for use in hazardous
locations when installed in suitable
enclosures such as B7E EXB, XJB, DB,
SWB and GCS Series boxes and B7,
Y7 Starter Enclosures.
Features
Operators are all aluminum except
for certain movable parts which are
stainless steel, all other parts such as
screws are either stainless steel or
plated steel
Threaded bodies are all 3/4"-14
NPSM thread
Control stations can be grouped into
a single assembly thus reducing
installation time and cost
Junction boxes may be used to
mount operators along with glass
lens for viewing internally mounted
meters. Additional relays, timers, ter-
minal blocks, or other equipment
may also be internally mounted to
provide a single centralized control
unit.
Custom operators other than
standard assemblies listed may be
ordered by proper catalog number
from custom operator ordering
system pages C40 & C41
Electrical Rating
Push button stations, selector switches
Heavy duty 600 VAC max.
Pilot lights 120 VAC.
Dimensions
See Dimensional information for
G Series operators on page C42.
Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
See Area Classification Chart below
potentiometer operators are CEN-
ELEC/ATEX EExd IIB+H2 when installed
in series EXB*CEN and GR*CEN enclo-
sures.
For pilot lights and illuminated push but-
tons in CENELEC/ATEX applications see
page C33.
GO14
GO24
GO54
GO64
GO74
GO83
GO104
GO144
GO154
GO162
GO172
GO182
GO192
GO212
GO222
GO232
GO252
GO262
GO272
GO282
GO302
GO342
GO352GO363
GO373
GO383
GO393
GO401
GO502
G0512
GO562
GO572
GO582
GO592
GO1133
GO1143
GO1332
GO1342
GOB34
GOB44
GOL14
GOL24
GOL34
GOL44
GOL54
GOL64
GOL74GOL83
GOL144
GOL154
GOL363
GOL374
GOL383
GOL393
GOL1133
GOL1143
GOLRST4
GOM15
GOR114
GORST4
GO113882
GO113722
G SERIES CONTROLS
PUSH BUTTONS C31
FEATURES-SPECIFICATIONS
C
G SINGLE PUSH BUTTON (MOMENTARY CONTACT)
CATALOG NUMBER1COLOR
Green
Black
Red
Black
Green
Red
Black
Green
Red
Black
CONTACT TYPE3
Start or Stop
Reset or Blank
Start or Stop
Reset or Blank
Reset or Blank
Reset or Blank
Reset or Blank
Reset or Blank
Reset or Blank
Reset or Blank
GO1-GX1B N34
GO1-KX1C N34
GO1-RX2B N34
GO1-KX2C N34
GO1-GX3C N34
GO1-RX3C N34
GO1-KX3C N34
GO1-GX0C N34
GO1-RX0C N34
GO1-KX0C N34
GOL1G1
GOL1K1
GOL1R2
GOL1K2
GOL1G3
GOL1R3
GOL1K3
GOL1G
GOL1R
GOL1K
None
GO21-GZ1B
GO21-KZ1C
GO21-RZ2B
GO21-KZ2C
GO21-GZ3C
GO21-RZ3C
GO21-KZ3C
GO21-GZ0C
GO21-RZ0C
GO21-KZ0C
SHORT4LONG EXTENDED NAMEPLATE MARKING2
G DOUBLE PUSH BUTTON (MOMENTARY CONTACT)
Start/Stop or Blank
Start/Stop or Blank
Start/Stop or Blank
Start/Stop or Blank
Start/Stop or Blank
Start/Stop or Blank
GO22-GR12D
GO22-KK12D
GO22-GR33D
GO22-KK33D
GO22-GR00D
GO22-KK00D
G02-GR12D N34
G02-KK12D N34
G02-GR33D N34
G02-KK33D N34
G02-GR00D N34
G02-KK00D N34
GOL2GR12
GOL2KK12
GOL2GR33
GOL2KK33
GOL2GR
GOL2KK
Listed - File E12379
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups B,C,D4
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
See Area Classification Chart
page C40 for Details
G DOUBLE PUSH BUTTON (MAINTAINED CONTACT)5
Start/Stop or Blank
Start/Stop or Blank
Start/Stop or Blank
Start/Stop or Blank
GOR11-GR6D N34
GOR11-GR7D N34
GOR11-GR8D N34
GOR11-GR0D N34
1Refer to catalog page C30 to select proper operator for enclosure, pages C38 & C39 for accessories, page C30 for complete details on
Area Classification of operators, page C42 for Dimensional information.
2Nameplates are double sided.
3Contact Blocks are shown in their normal position.
4Short style operators are suitable for Class l Group C & D, Class ll Group E,F,G only.
5When pressed, the green button will remain in a depressed position. Pressing red button releases green from the depressed position.
• •
• •
• •
• •
Green/Red
Black/Black
Green/Red
Black/Black
Green/Red
Black/Black
• •
• • • •
• •
None
• • • •
None
Green/Red
Green/Red
Green/Red
Green/Red
• • • •
• • • •
• •
• •
• •
• •
Double Push Button
Single Push Button
Long
Single Push Button
Extended
“G” Series Operator
Maintained
G SINGLE PUSH BUTTON (MAINTAINED CONTACT) MUSHROOM HEAD PUSH - PULL OPERATION
Blank
Blank
Blank
Blank
Blank
Blank
GOM21-GM3C
GOM21-RM3C
GOM21-KM3C
GOM21-GM0C
GOM21-RM0C
GOM21-KM0C
GOM1-GM3C N34
GOM1-RM3C N34
GOM1-KM3C N34
GOM1-GM0C N34
GOM1-RM0C N34
GOM1-KM0C N34
GOML1G3
GOML1R3
GOML1K3
GOML1G
GOML1R
GOML1K
Green
Red
Black
Green
Red
Black
• •
• •
None
GS SERIES CONTROLS
PILOT LIGHTS
C32
FEATURES-SPECIFICATIONS
GOL4A3
GOL4B3
GOL4C3
GOL4F3
GOL4G3
GOL4R3
GOL4A
GOL4B
GOL4C
GOL4F
GOL4G
GOL4R
G PILOT LIGHTS
CATALOG NUMBER1
COLOR
Amber
Blue
Clear
Frosted
Green
Red
CONTACT TYPE3
Blank
Blank
Blank
Blank
Blank
Blank
GOL3A
GOL3B
GOL3C
GOL3F
GOL3G
GOL3R
110-120 Volts
Full Volts
GOB3-A23C N34
GOB3-B23C N34
GOB3-C23C N34
GOB3-F23C N34
GOB3-G23C N34
GOB3-R23C N34
SHORT4LONG EXTENDED NAMEPLATE MARKING2
GO23-A23C
GO23-B23C
GO23-C23C
GO23-F23C
GO23-G23C
GO23-R23C
G ILLUMINATED BUTTON OR PUSH TO TEST PILOT LIGHT
Amber
Blue
Clear
Frosted
Green
Red
Amber
Blue
Clear
Frosted
Green
Red
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
110-120 Volts
No Contact
Blocks
GOB4-A233C N34
GOB4-B233C N34
GOB4-C233C N34
GOB4-F233C N34
GOB4-G233C N34
GOB4-R233C N34
GOB4-A230C N34
GOB4-B230C N34
GOB4-C230C N34
GOB4-F230C N34
GOB4-G230C N34
GOB4-R230C N34
1Refer to catalog page C30 to select proper operator for enclosure, pages C38 & C39 for accessories, page C30 for com
plete details on Area Classification of operators, page C42 for Dimensional information.
2Nameplates are double sided.
3Contact Blocks are shown in their normal position.
4Short style operators are suitable for Class l Group C & D, Class ll Group E,F,G only.
Listed - File E12379
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups B,C,D4
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
See Area Classification Chart
page C40 for Details
G ILLUMINATED BUTTON OR PUSH TO TEST PILOT LIGHT WITH LED 110 VOLT LAMPS
Amber
Green
Red
Amber
Green
Red
Blank
Blank
Blank
Blank
Blank
Blank
110-120 Volts (LED)
No Contact Blocks
GOB4-A233C N34 LED
GOB4-G233C N34 LED
GOB4-R233C N34 LED
GOB4-A230C N34 LED
GOB4-G230C N34 LED
GOB4-R230C N34 LED
G PILOT LIGHTS WITH LED 110 VOLT LAMPS
Amber
Green
Red
Blank
Blank
Blank
GOB3-A23C N34 LED
GOB3-G23C N34 LED
GOB3-R23C N34 LED
GOL3A LED
GOL3G LED
GOL3R LED
GOL4A3 LED
GOL4G3 LED
GOL4R3 LED
GOL4A LED
GOL4G LED
GOL4R LED
110-120 Volts
Full Volts (LED)
110-120 Volts
Full Volts
• •
• •
110-120 Volts
Full Volts (LED) • •
• •
Pilot Light Illuminated Button
G SERIES CONTROLS
PILOT LIGHTS FOR ATEX/CENELEC APPLICATIONS C33
FEATURES-SPECIFICATIONS
C
G PILOT LIGHTS
CATALOG NUMBER1COLOR
Amber
Blue
Clear
Frosted
Green
Red
CONTACT TYPE3
Blank
Blank
Blank
Blank
Blank
Blank
GOL3ACN
GOL3BCN
GOL3CCN
GOL3FCN
GOL3GCN
GOL3RCN
110-120 Volts
Full Volts
GOB3-A23C N34CN
GOB3-B23C N34CN
GOB3-C23C N34CN
GOB3-F23C N34CN
GOB3-G23C N34CN
GOB3-R23C N34CN
LONG EXTENDED NAME PLATE MARKING2
G ILLUMINATED PUSH BUTTON OR PUSH TO TEST PILOT LIGHT
Amber
Blue
Clear
Frosted
Green
Red
Amber
Blue
Clear
Frosted
Green
Red
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
110-120 Volts
No Contact
Blocks
GOB4-A233CN34CN
GOB4-B233CN34CN
GOB4-C233CN34CN
GOB4-F233CN34CN
GOB4-G233CN34CN
GOB4-R233CN34CN
GOB4-A230CN34CN
GOB4-B230CN34CN
GOB4-C230CN34CN
GOB4-F230CN34CN
GOB4-G230CN34CN
GOB4-R230CN34CN
1Refer to catalog page C30 to select proper operator for enclosure, pages C38 & C39 for accessories, page C30 for
complete details on Area Classification of operators, page C42 for Dimensional information.
2Nameplates are double sided.
3Contact Blocks are shown in their normal position.
NOTE: British standards BSEN50014 and EN50018 have special marking and relamping
demands that require modifications to the standard Killark Pilot Lights. Pilots lights
and illuminated push buttons on this page must be used for enclosures that are mod-
ified to meet ATEX/CENELEC.
Listed - File E12379
Certified - File LR11714
PTB No. 03ATEX 1203 U
Class I, Div. 1 & 2, Groups B,C,D
Class I, Zones 1 & 2, Groups llB+H2, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
ATEX-EExd IIB + H2
G ILLUMINATED PUSH BUTTON OR PUSH TO TEST PILOT LIGHT WITH LED 110 VOLT LAMPS
Amber
Green
Red
Amber
Green
Red
Blank
Blank
Blank
Blank
Blank
Blank
110-120 Volts (LED)
No Contact Blocks
GOB4-A233CN34LEDCN
GOB4-G233CN34LEDCN
GOB4-R233CN34LEDCN
GOB4-A230CN34LEDCN
GOB4-G230CN34LEDCN
GOB4-R230CN34LEDCN
G PILOT LIGHTS WITH LED 110 VOLT LAMPS
Amber
Green
Red
Blank
Blank
Blank
GOB3-A23C N34LEDCN
GOB3-G23C N34LEDCN
GOB3-R23C N34LEDCN
GOL3ALEDCN
GOL3GLEDCN
GOL3RLEDCN
GOL4A3LEDCN
GOL4G3LEDCN
GOL4R3LEDCN
GOL4A0LEDCN
GOL4G0LEDCN
GOL4R0LEDCN
110-120 Volts
Full Volts (LED)
110-120 Volts
Full Volts
• •
• •
110-120 Volts
Full Volts (LED) • •
• •
Pilot Light ATEX Illuminated Push Button ATEX
GOL4A3CN
GOL4B3CN
GOL4C3CN
GOL4F3CN
GOL4G3CN
GOL4R3CN
GOL4A0CN
GOL4B0CN
GOL4C0CN
GOL4F0CN
GOL4G0CN
GOL4R0CN
G SERIES CONTROLS
SELECTOR SWITCHES
C34
G SELECTOR SWITCH MAINTAINED CONTACT WITHOUT CONTACTS
G025-2A0F
G025-3C0G
G025-4H0H
G0L52A
G0L53C
G0L54H
G05-2A0F N34
G05-3C0G N34
G05-4H0H N34
Two position
Three position
Four position
None
None
None
G SELECTOR SWITCH SPRING RETURN WITHOUT CONTACTS
G026-0F
G027-0G
G034-0G
G035-0G
G0L6
G0L7
G0L14
G0L15
G06-0F N34
G07-0G N34
G014-0G N34
G015-0G N34
Two position spring return to left
Three position spring return to
center from right or left
Three position spring return to
center from right, maintain in left
Three position spring return to
center from left, maintain in right
None
None
None
None
G SELECTOR SWITCH MAINTAINED CONTACT
CATALOG NUMBER1
CONTACT ARRANGEMENT3
SHORT4LONG EXTENDED TYPE OF OPERATION2
Listed - File E12379
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups B,C,D4
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
See Area Classification Chart
page C40 for Details
Two position
Three position
Four position
Left Right
Left RightCenter
• •
G SELECTOR SWITCH SPRING RETURN
G026-3F
G027-6G
G034-6G
G035-6G
G0L63
G0L76
G0L146
G0L156
G06-3F N34
G07-6G N34
G014-6G N34
G015-6G N34
Two position spring return to left
Three position spring return to
center from right or left
Three position spring return to
center from right, maintain in left
Three position spring return to
center from left, maintain in right
• •
• •
1Refer to catalog page C30 to select proper operator for enclosure, C38 & C39 for Accessories, C30 for complete details on
Area Classification of operators, C42 for Dimensional Information, C40 for Special Contact Configurations.
2Nameplates are Double sided. 2 position marked ON-OFF and Blank on other side.
3 position marked HAND-OFF-AUTO and Blank on other side. 4 position is Blank.
3Contact Blocks are shown in their normal position.
4Short style operators are suitable for Class I Group C & D, Class II Group E,F,G only.
• •
• •
• •
• •
• •
• •
• •
• •
• •
Left Right
• •
• •
Selector Switch
Spring Return
Selector Switch
Maintained Contact
• • • •
• •
• •
• •
• • • •
• •
• •
• •
• • • •
• •
• •
• • • •
1 2 3 4
Left Right
Center
• •
• • • •
• •
• •
• •
Left Right
Center
• •
• •
• •
• •
• •
• •
Left
Right
Center
• •
• • • •
• •
• •
• •
G025-2A3F
G025-3C3G
G025-4H8H
G05-2A3F N34
G05-3C3G N34
G05-4H8H N34
G0L52A3
G0L53C3
G0L54H8
FEATURES-SPECIFICATIONS
G SERIES CONTROLS
KEYED SELECTOR SWITCHES C35
FEATURES-SPECIFICATIONS
C
G KEY SELECTOR SWITCH MAINTAINED CONTACT4
CATALOG NUMBER1
CONTACT ARRANGEMENT3
SHORT6LONG EXTENDED TYPE OF OPERATION25
G028-2A3F22D
G028-3C3G32D
G0L82A322D
G0L83C332D
G08-2A3F22D N34
G08-3C3G32D N34
Two position
Three position
Left Right
Left RightCenter
Listed - File E12379
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups B,C,D6
Class 1, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
See Area Classification Chart
page C40 for Details
1Refer to catalog page C30 to select proper operator for enclosure, pages C38 & C39 for Accessories, page C30 for complete
details on Area Classification of operators, page C42 for Dimensional Information, page C40 for Special Contact Configurations.
2Nameplates are Double sided. 2 position marked ON-OFF and Blank on other side. 3 position marked HAND-OFF-AUTO
and Blank on other side. 4 position is Blank.
3Contact Blocks are shown in their normal position.
4All Key Operators are furnished Keyed Different If Keyed Alike is required substitute letter “A” for letter “D” in catalog number.
5Keys are removable in Left position on 2 position selectors and in Center position on 3 position selectors. For key removal
in ALL positions change “22” in 2 position to “20” and “32” in 3 position to “30”.
6Short style operators are suitable for Class I Group C & D, Class II Group E,F,G only.
G KEY SELECTOR SWITCH SPRING RETURN4
G056-2L3F22D
G057-3C6G32D
G058-3L6G32D
G059-3R6G32D
G036-2L3F22D N34
G037-3C6G32D N34
G038-3L6G32D N34
G039-3R6G32D N34
G KEY SELECTOR SWITCH MAINTAINED CONTACT WITHOUT CONTACTS4
G028-2A0F22D
G028-3C0G32D
G0L82A022D
G0L83C032D
G08-2A0F22D N34
G08-3C0G32D N34
Two position
Three position
None
None
• •
• •
• •
• •
• •
• •
• •
• •
• •
• •
G KEY SELECTOR SWITCH SPRING RETURN WITHOUT CONTACTS4
G056-2L0F22D
G057-3C0G32D
G058-3L0G32D
GO59-3R0G32D
G0L36L022D
G0L37C032D
G0L38L032D
G0L39R032D
G036-2L0F22D N34
G037-3C0G32D N34
G038-3LOG32D N34
G039-3R0G32D N34
Two position spring return to left
Three position spring return to
center from right or left
Three position spring return to
center from right, maintain in left
Three position spring return to
center from left, maintain in right
None
None
None
None
Key Operated
Selector Switch
• •
• •
• •
• •
Left Right
• •
• • • •
• •
• •
• •
Left Center Right
• •
• • • •
• •
• •
• •
Left Center Right
• •
• • • •
• •
• •
• •
Left Center Right
Two position spring return to left
Three position spring return to
center from right or left
Three position spring return to
center from right, maintain in left
Three position spring return to
center from left, maintain in right
G0L36L322D
G0L37C632D
G0L38L632D
G0L39R632D
G SERIES CONTROLS
SPECIALTY OPERATORS
C36
FEATURES-SPECIFICATIONS
TYPE
SWITCH
SPST
SPDT
(3-way)
Class I, Div. 1 & 2, Groups B,C,D4
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
See Area Classification Chart
page C40 for Details
See file for details or call Killark.
Certified - File LR11714
RATINGS
125 VAC 2 50 VAC
10 Amp 5 Amp
10 Amp 10 Amp
NAMEPLATE
MARKING2
Off/On
or Blank
Off/On
or Blank
CATALOG NUMBER1
SHORT4
GO30-31F
GO30-33F
LONG
GO10-31F N34
GO10-33F N34
G SNAP SWITCH OPERATOR
(UL File E10501)
CATALOG NUMBER1
SHORT4
GO133
GO134
LONG
GO113 N34
GO114 N34
G POTENTIOMETERS AND RHEOSTATS OPERATOR
(UL File E150827)
TYPE
Single turn
Fifteen turn
EXTENDED
GOL113
GOL114
DESCRIPTION1
Control operator for use
with potentiometers or
rheostats having a 1/4"
diameter by 7/8" long
shaft.
CATALOG
NUMBER1
GO-11388-0785
GO-11372-0935
G CAPILLARY SEALS
TYPE
Accepts
Capillary
With Max.
Bulb Dia.
of 9/16".
CAPILLARY
SIZE
0.078±
.002 Dia.
0.093±
.002 Dia.
DESCRIPTION1
Use where a mechanical
means for passing a thermo-
stat or similar capillary tube
through the wall of a haz-
ardous location enclosure.
CATALOG
NUMBER1
GO-165
GO-185
GO-175
GO-195
GO-50
GO-51
SHAFT
DIAMETER
1/4”
3/8”
1/4”
3/8”
1/2”
1/2”
G ROTARY OR MOTOR SHAFT OPERATOR
GO50 requires 1-1/4" NPSM opening (UL File E150827)
TYPE
Male-Female
Male-Male
DESCRIPTION1
Rotary or motor shaft
operator used to
transfer rotary motion
through wall of explo-
sion proof enclosure.
CATALOG NUMBER1
SHORT3
GO40-KX2C
LONG
GO-RST
G RESET OPERATOR
(UL File E150827)
NAMEPLATE2
Reset
or
Blank
EXTENDED
GOLRST
TYPE OPERATION1
Black plunger type reset
operator, supplied with a
6” long fiber extension
which can be removed or
cut to desired length.
1Refer to catalog page C30 to select proper operator for enclosure, pages
C38 & C39 for Accessories, page C30 for complete details on Area
Classification of operators, page C42 for Dimensional Information.
2Nameplates are double sided.
3GO40 series reset button is suitable for Class II E, F, and G locations only.
4Short style operators are suitable for Class I Group C & D, Class II Group
E,F,G only.
5These devices are not UL or CSA approved.
• •
• •
Snap Switch Reset
Capillary Seal
Rotary or Motor Shaft
Potentiometer and Rheostat
(electrical device not included)
GCS/SWBC SERIES CONTROLS
OPERATOR BODIES C37
FEATURES-SPECIFICATIONS
C
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
SWBC Series:
Listed - File E10514
Certified - File LR11716
See files for details or call Killark.
1All GCS and SWBC Series are cataloged without conduit openings.
Specify conduit size and location when ordering.
2GCS-83, GCS-834, and GCS-85, GCS-835 are provided with four
mounting lugs.
NO. OF
CATALOG OPERATOR CONSISTS OF DIMENSIONS
NUMBER HOLES BOX COVER AB CD EGH I
GCS-13 1 SWB-13 X-60 6-1/8" 2-3/8" 5/16" 5-3/16" 3-5/8" 3-1/2" 2-9/16"
(156) (60) (8) (148) (92) (89) (65)
GCS-14 1 SWB-14 X-60 6-1/8" 2-3/8" 5/16" 5-1/4" 3-5/8" 4-5/16" 3-3/8"
(156) (60) (8) (133) (92) (110) (86)
GCS-15 2 SWB-15 X-61 7-3/8" 3-1/8" 5/16" 6-1/2" 4" 1" 4-1/4" 3-1/4"
(187) (79) (8) (165) (102) (25) (108) (82)
GCS-16 3 SWB-16 X-62 9-3/8" 3-3/16" 5/16" 8-1/2" 4" 2" 4-1/4" 3-1/4"
(238) (81) (8) (216) (108) (51) (105) (82)
GCS-83 4 SWB-832X-84 13" 3-1/4" 3/8" 11-7/8" 4-3/8" 1-1/4" 4-3/16" 3-1/4"
(330) (82) (10) (302) (111) (32) (106) (82)
GCS-85 5 SWB-832X-85 13" 3-1/4" 3/8" 11-7/8" 4-3/8" 2" 4-3/16" 3-3/16"
(330) (82) (10) (302) (111) (51) (106) (81)
GCS STYLE 1 – WITH DRILLED AND TAPPED OPERATOR HOLES IN COVER1
Style 1 - GCS-16 Style 2 - GCS-163
Dimensions
Notes: Use short style operators for cover
devices and long style operators for
back of box mounted devices when
panel mounting.
Style 2 control stations with holes in
back of box are typically used for panel
mounting.
GCS-131 1 SWB-13 X-10 6-1/8" 2-3/8" 5/16" 5-3/16" 3-5/8" 3-1/2" 2-9/16"
(156) (60) (8) (148) (92) (89) (65)
GCS-141 1 SWB-14 X-10 6-1/8" 2-3/8" 5/16" 5-1/4" 3-5/8" 4-5/16" 3-3/8"
(156) (60) (8) (133) (92) (110) (86)
GCS-152 2 SWB-15 X-11 7-3/8" 3-1/8" 5/16" 6-1/2" 4" 1" 4-1/4" 3-1/4"
(187) (79) (8) (165) (102) (25) (108) (82)
GCS-163 3 SWB-16 X-12 9-3/8" 3-3/16" 5/16" 8-1/2" 4" 2" 4-1/4" 3-1/4"
(238) (81) (8) (216) (102) (51) (108) (82)
GCS-834 4 SWB-832X-83 13" 3-1/4" 3/8" 11-7/8" 4-3/8" 1-1/4" 4-3/16" 3-1/4"
(330) (82) (10) (302) (111) (32) (106) (82)
GCS-835 5 SWB-832X-83 13" 3-1/4" 3/8" 11-7/8" 4-3/8" 2" 4-3/16" 3-3/16"
(330) (82) (10) (302) (111) (51) (106) (81)
GCS STYLE 2 – WITH DRILLED AND TAPPED OPERATOR HOLES IN BACK OF BOX1
SWBC-13 None SWB-13 X-10 6-1/8" 2-3/8" 5/16" 5-3/16" 3-5/8" 3-1/2" 2-9/16"
(156) (60) (8) (148) (92) (89) (65)
SWBC-14 None SWB-14 X-10 6-1/8" 2-3/8" 5/16" 5-1/4" 3-5/8" 4-5/16" 3-3/8"
(156) (60) (8) (133) (92) (110) (86)
SWBC-15 None SWB-15 X-11 7-3/8" 3-1/8" 5/16" 6-1/2" 4" 4-1/4" 3-1/4"
(187) (79) (8) (165) (102) (108) (82)
SWBC-16 None SWB-16 X-12 9-3/8" 3-3/16" 5/16" 8-1/2" 4" 4-1/4" 3-1/4"
(238) (81) (8) (216) (111) (108) (82)
SWBC-83 None SWB-832X-83 13" 3-1/4" 3/8" 11-7/8" 4-3/8" 4-3/16" 3-3/16"
(330) (82) (10) (302) (111) (106) (81)
SWB STYLE 3 – BLANK BOX AND COVER - NO OPERATOR HOLES1
Style 3 - SWBC-16
Rubber
Boot
Hole
Plug
Trim Locknut
Spacer
Selector Switch Lockout
CATALOG NUMBER USED ON OPERATOR TYPE DESCRIPTION
GO1, GO21, GOL1
GO1, GO21, GOL1
GO1, GO21, GOL1
3/4” NPSM
1/4” Thick, Used as external spacer.
GO23, GOB3, GOL3
GO23, GOB3, GOL3
GOB4, GOL4
GOB4, GOL4
GO2, GO22, GOL2, GOR11
GO1, GO21, GOL1
GO & GOL5-6-7-14-15-26-27-34-35
For use with GO’s
GO40, GO-RST, GOLRST
GO23, GOB3, GOL3, GOB4, GOL4
GO23, GOB3, GOL3, GOB4. GOL4
GO23, GOB3, GOL3, GOB4, GOL4
GOB3, GOL3, GOB4, GOL4
GOB3, GOL3, GOB4, GOL4
GOB3, GOL3, GOB4, GOL4
GO-8176-1
GO-8176-2
GO-8176-3
GO-8177
GO-8222
GO-8670-32
GO-8670-34
GO-8671-42
GO-8671-44
GO-8665
GO-10502
GO567-LOK
GO-RL
GO-9824
B7PLR220
B7PLR440
B7PLR550
GOLED-R110
GOLED-G110
GOLED-A110
Protective rubber boot (Black)
Protective rubber boot (Red)
Protective rubber boot (Green)
Hole plug
Trim locknut spacer
Transformer 220V-110V
Transformer 440V-110V
Transformer 220V-110V
Transformer 440V-110V
Push button lockout
Push button lockout
Selector switch lockout
Sealing lockout
Reset plate
Resistor kit 220V-110V
Resistor kit 440V-110V
Resistor kit 550V-110V
LED lamps 120V (Red)
LED lamps 120V (Green)
LED lamps 120V (Amber)
ACCESSORIES
REPLACEMENT LENS GUARD ASSEMBLIES
CATALOG NUMBER
GOL3/GOB3/GO23 SERIES GOL4/GOB4 SERIES LENS COLOR
GO15726-A KIT-354 Amber
GO15726-B KIT-355 Blue
GO15726-C KIT-356 Clear
GO15726-F KIT-357 Frosted
GO15726-G KIT-358 Green
GO15726-R KIT-359 Red
Lens Guard
Assembly
CATALOG NUMBER DESCRIPTION
YOKK-9484-2 Push button pilot lights
YOKK-10291 Double push button
YOKK-10286 2 Position selector switch
YOKK-10287 3 Position selector switch
YOKK-10285 4 Position selector switch
REPLACEMENT BLANK NAMEPLATES
Reset Plate
Push Button Lockout
GO-8665
Sealing Locknut
GO-RL
Transformer
GO-8670
Push Button Lockout
GO-10502
G SERIES CONTROLS
ACCESSORIES/REPLACEMENT PARTS
C38
C49
Slide Base
GO23
CATALOG
NUMBER VOLTS WATTS AMPS STYLE
GO-8668-120 120 3 0.025 GO23
GO-8668-24 24 1.7 0.073
YOSY120MB 120 3 0.025 GOB3/GOL3
YOSY24MB 24 1.7 0.073 GOB4/GOL4
PILOT LIGHT LAMPS
Bayonet Base
GOL3/GOL4
GOB3/GOB4
Replacement
Parts
CATALOG NUMBER FOR USE ON OPERATOR TYPE DESCRIPTION
GOM1-GOM21-GOML-GO1-GO21-GOL1
GO1-GO21-GOL1
GO1-GO21-GOL1
GO1-GO21-GOL1
GO1-GO21-GOL1
GOMLOCK
GOMSTG
GOMSTR
GOMSTK
GOMJUR
Lock Out for Standard Size Momentary & Maintained Head
Standard Size Momentary Mushroom Head (Green)
Standard Size Momentary Mushroom Head (Red)
Standard Size Momentary Mushroom Head (Black)
Jumbo Size Momentary Mushroom Head (Red)
ACCESSORIES
Dimensions - Standard Mushroom - 1-1/2” Diameter
Jumbo Mushroom - 2-1/4” Diameter
GOMLOCK Jumbo Mushroom
Momentary
Standard Mushroom
Momentary
Contact Block
CATALOG NUMBER DESCRIPTION
GO-8672-BJK 1 N.O.
GO-8672-BJJ 1 N.C.
GO-8672-BJH 1 N.O. Early make
GO-8672-BJE 1 N.C. Late break
GO STANDARD CONTACT BLOCKS
CATALOG NUMBER VOLTS COLOR
GOLED-A110 110 VAC/DC Amber
GOLED-B110 110 VAC/DC Blue
GOLED-G110 110 VAC/DC Green
GOLED-R110 110 VAC/DC Red
GOLED-W110 110 VAC/DC White
GOLED-A24 24 VAC/DC Amber
GOLED-B24 24 VAC/DC Blue
GOLED-G24 24 VAC/DC Green
GOLED-R24 24 VAC/DC Red
GOLED-W24 24 VAC/DC White
PILOT LIGHT LED LAMPS
LED Lamp for G0B3/G0L3 - G0B4/G0L4
G SERIES CONTROLS
ACCESSORIES/REPLACEMENT PARTS C39
C
G SERIES CONTROLS
CUSTOM OPERATOR ORDERING SYSTEM
C40
FEATURES-SPECIFICATIONS
1. Select operator form and style
(short, long or extended).
2.Using the catalog numbering system
below, insert the proper letter or
number symbol as shown in appro-
priate charts on page C41, write the
complete catalog number.
GO1
FORM
SINGLE PUSH BUTTON
LONG STYLE
RX
COLOR
(RED)
2
CONTACTS
(1 N.C.)
B
NAMEPLATE
(STOP)
N34
CONSTANT
Example:
NOTE: For faster delivery on custom operators order push buttons and selector
switches without contact blocks and order contacts as a separate item.
GO1 & GO21
GOL1
GOM1
GO2 & GO22
GOL2
GOR11
GOB3 & GO23
GOL3
GOB4
GOL4
GO5 & GO25
GOL5
GO6 & GO26
GOL6
GO7 & GO27
GOL7
GO14 & GO34
GOL14
GO15 & GO35
GOL15
GO8 & GO28
GOL8
GO36 & GO56
GOL36
GO37 & GO57
GOL37
GO38 & GO58
GOL38
GO39 & GO59
GOL39
Chart 1
Chart 1
Chart 2
Chart 2
Chart 3
Chart 3
Chart 6
Chart 6
Chart 5
Chart 5
Chart 7
Chart 7
Chart 4
Chart 4
Chart 4
Chart 4
Chart 4
Chart 4
Chart 4
Chart 4
Chart 4
Chart 4
Chart 4
Chart 4
Chart 4
Chart 4
Chart 4
Chart 8
Chart 8
Chart 8
Chart 8
Chart 8
Chart 8
Chart 8
Chart 8
Chart 8
Chart 8
Chart 8
Chart 8
Chart 8
Chart 8
Chart 8
Chart 8
Chart 10
Chart 10
Chart 10
Chart 10
Chart 10
Single push button:
(Momentary contact)
Single push button:
(Maintained contact)
Double push button:
(Momentary contact)
Double push button:
(Maintained contact)
Pilot light
Illuminated push button
Selector switch
(Maintained contact)
Selector switch
(2 Position, spring return to left)
Selector switch
(3 Position, return to center from center)
Selector switch
(3 Position, return to center from right)
Selector switch
(3 Position, return to center from left)
Key selector switch
(Maintained contact)
Key selector switch
(2 Position, spring return to left)
Key selector switch
(3 Position, spring return to center)
Key selector switch
(3 Position, return to center from right)
Key selector switch
(3 Position, return to center from left)
Chart 9
Chart 9
Chart 9
Chart 9
Chart 9
DESCRIPTIONCATALOG SERIES COLOR VOLTAGE POSITION CAM CONTACTS NAMEPLATE KEY LOCK KEY TYPE
3.Spaces in catalog numbering sys-
tem which have symbol already
filled in cannot be changed.
4.Order accessories as separate
item from pages C38 & C39.
5.Add “N34” suffix to the end of all
long style operators with the follow-
ing prefix; G01, G02, G0B3, G0B4,
G05, G06, G07, G08, G010, G011,
G014, G015, G036, G037, G038,
G039.
HAZARDOUS AND HOSTILE LOCATIONS
G SYMBOLS FOR ORDERING CUSTOM OPERATORS C41
C
A
B
C
D
E
G
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
SYMBOL ARRANGEMENT
1One N.O. block
2One N.C. block
One universal
3(One N.O. and one N.C.)
One delayed break
4N.C. block
One early make N.O.
5block
6Two N.O. blocks
7Two N.C. blocks
Two universal
8(Two N.O. and two N.C.)
0Omit contact block
CHART 4 – CONTACT BLOCKS
GO1 GO21
SYMBOL SYMBOL COLOR
KX KZ Black
RX RZ Red
GX GZ Green
SYMBOL COLOR
KK Black/Black
GG Green/Green
RR Red/Red
RG Red/Green
KR Black/Red
KG Black/Green
CHART 1 – SINGLE BUTTON
CHART 2 – DOUBLE BUTTON
GOL1 GOM1
SYMBOL SYMBOL
K KM
R RM
G GM
SYMBOL NO. OF POSITIONS
2Two
3Three
CHART 5 – SELECTOR SWITCHES
CHART 8 – NAMEPLATES1
NAMEPLATE MARKINGS G SERIES FORMS THAT
SYMBOL FRONT BACK NAMEPLATE CAN BE USED ON
A Omit nameplate Omit nameplate All
B Start Stop GO1, 21, 23, 20, 40, GOB3
C Blank Reset GO1, 21, 23, 20, 40, GOB3, GOB4
E Blank On GOR4
F Blank-Blank Off-On GO5, 25, 6, 26, 8, 28, 10, 30, 36, 56
G Blank-Blank-Blank Hand-Off-Auto GO5, 25, 7, 27, 8, 28, 10, 30, 14, 34
H Blank-Blank-Blank-Blank Start-Stop GO5, 25, 10, 30
SYMBOL TYPE
22 2 Position key remove left
20 2 Position key remove both
32 3 Position key remove center
30 3 Position key remove all
CHART 9 – KEY LOCK
1Symbol not required on extended length GOL
part number.
SYMBOL COLOR
AAmber
BBlue
CClear
FFrosted
GGreen
RRed
CHART 3 – PILOT LIGHT LENS
GO23 GOB3/GOB4
SYMBOL SYMBOL VOLTAGE
23 23 120
4424
CHART 6 – PILOT LIGHT LAMPS SYMBOL TYPE
DKeys different
AKeys alike
CHART 10 - KEY STYLE
CAM AND CONTACT SELECTION TABLE FOR 2 AND 3 POSITION SELECTOR OPERATOR
LEFT RIGHT LEFT RIGHT LEFT RIGHT
BLOCKS BLOCKS BLOCKS BLOCKS BLOCKS BLOCKS
XXOO
OO XX
XOXXOX
O X O OXO
X X OOO O
OOOOX X
OOXXO O
OOOOX X
OOXXO O
XXOOO O
X O OXO O
OOOOX X
CONTACTS BLOCKS
SYMBOL
CHART 7A – SELECTOR SWITCH CAMS
Note: Spring return operators are supplied with special fixed cam. Changes cannot be made for cam
substitution.
Left Center Right
position position position
CAM PART NUMBER
A0106775B
B11586ABAB
C11587ABAB
D11588ABAB
E11589ABAB
G11590ABAB
CHART 7B
G SERIES CONTROLS
DIMENSIONS
C42
GO1
GO2
GOB3
GOB4
GO5
GO6,GO7,GO14,GO15
GO8
GO10
GO16,GO18
GO17,GO19
GO21
GO22
GO23
GO25
GO26,GO27,GO34,GO35
GO30
GO36,GO37,GO38,GO39
GO40
GO50
GO51
GO56,GO57,GO58,GO59
GO113,GO114
GO133,GO134
GO-11388-078
GO-11372-093
GOR11
GO-RST
GOM1
EXTENDED LENGTH OPERATORS:
GOL1
GOL2
GOL3
GOL4
GOL5
GOL6,GOL7,GOL14,GOL15
GOL8
GOL36,GOL37,GOL38,GOL
GOL113,GOL114
GOLRST
SERIES FIGURE A
1
3
4
5
9
9
10
11
7
7
1
3
4
9
9
11
10
2
7
7
10
6
6
8
8
3
2
1
1
3
4
5
9
9
10
10
6
2
15/16"(24)
13/16"(21)
1-1/8"(29)
2-3/8"(60)
1-5/16"(33)
1-5/16"(33)
2-9/16"(65)
1-5/16"(33)
1-1/4"(32)
13/16"(21)
15/16"(24)
13/16"(21)
1-1/8"(29)
1-5/16"(33)
1-5/16"(33)
1-5/16"(33)
2-9/16"(65)
15/16"(24)
1-1/2"(38)
2-1/4"(57)
2-9/16"(65)
1"(25)
1"(25)
1-5/16"(33)
1-5/16"(33)
13/16"(21)
15/16"(24)
1-7/8"(48)
15/16"(24)
13/16"(210)
1-1/8"(29)
2-3/8"(60)
1-5/16"(33)
1-5/16"(33)
2-9/16"(65)
2-9/16"(65)
1"(25)
15/16"(24)
B
1-3/4"(44)
2"(51)
2"(51)
2-1/4"(57)
1-3/4"(44)
1-3/4"(44)
1-3/4"(44)
1-3/4"(44)
1"(25)
1"(25)
3/4"(19)
1"(25)
1"(25)
3/4"(19)
3/4"(19)
3/4"(19)
1-3/4"(00)
11/16"(17)
2"(51)
1-5/8"(41)
3/4"(19)
2"(51)
1"(25)
3/4"(19)
3/4"(19)
2"(51)
2-5/16"(59)
1-7/16"(37)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
2-3/4"(70)
3"(76)
2-3/4"(70)
C
3-7/16"(87)
3-3/4"(95)
2-3/4"(70)
4"(101)
3-7/16"(87)
3-13/16"(97)
3-1/2"(89)
4"(101)
13/16"(21)
13/16"(21)
2-7/16"(62)
2-3/4"(70)
1-3/4"(44)
2-7/16"(62)
2-13/16"(71)
3"(76)
3-7/8"(98)
1"(25)
6-5/16"(160)
5-9/16"(141)
2-7/8"(73)
3-5/8"(67)
2-5/8"(67)
N/A
N/A
4-1/8"(105)
2-3/8"(+6")(60)
4"(101)
4-7/16"(113)
4-1/2"(114)
3-3/8"(86)
4-5/8"(117)
4-7/16"(113)
4-13/16"(122)
4-1/2"(114)
4-7/8"(124)
4-5/8"(117)
3"(+6")(76)
D
1-1/4"(32)
1-9/16"(40)
1-13/16"(46)
1-1/4"(32)
1-1/4"(32)
1-1/4"(32)
1-1/4"(32)
1-1/2"(38)
1-1/2"(38)
1-1/4"(32)
1-9/16"(40)
1-1/4"(32)
1-1/4"(32)
1-1/4"(32)
1-1/4"(32)
1-1/4"(32)
2-5/16"(59)
1"(25)
1-1/4"(32)
1-13/16"(46)
1-13/16"(46)
1-1/2"(38)
1-1/2"(38)
1-1/4"(32)
1-5/8"(41)
1-1/4"(32)
1-9/16"(40)
1-13/16"(46)
1-1/4"(32)
1-1/4"(32)
1-1/4"(32)
1-1/4"(32)
1-13/16"(46)
1-1/4"(32)
NOTE: All operators are for installation into a 3/4"-14 NPSM opening except GO50 which is for
1-1/4"-11-1/2 NPSM and GO-11388-078 + GO-11372-093 which are for use in a 3/4"-14 NPT opening.
Push Buttons
Pilot Lights
Special Operators
Selector Switches
FIGURE 1
FIGURE 2
FIGURE 3
FIGURE 4
FIGURE 5
FIGURE 6 FIGURE 7 FIGURE 8
FIGURE 9 FIGURE 10 FIGURE 11
G DIMENSIONS
B7 SERIES CONTROLS
MAGNETIC MOTOR STARTERS C43
FEATURES-SPECIFICATIONS
C
Applications
The PRISM® B7 Series of across-the-
line starter and combination motor con-
trol centers utilize SSNR single-speed,
non-reversing NEMA type starters.
Prism enclosures universal design
accommodates, as standard, the mag-
netic starters made by the following
manufacturers:
Allen-Bradley — 509 Series
Cutler-Hammer — A10 Series
Cutler-Hammer — AN16 Series
Furnas — Class 14 Series
GE — CR306 Series
Square D — 8536 Series
Telemecanique — A20 Series
Westinghouse — A200 Series
In addition, the SSNR combination
starters will house a motor circuit
protector or circuit breakers manufac-
tured by:
Square D — FA, FH, FC Frames
Cutler-Hammer –– HMC, EHD, FDB,
FD, HFD, FDC Frames
General Electric –– TEB-TEC-TED-
THED-Frame
There is sufficient space in the combina-
tion starter enclosure for a control
transformer, if required.
Classified - File E83969
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
Standard Materials
Enclosure – Copper-free aluminum
O-ring Gasket – BUNA-N nitrile
Cover Bolts – 316 grade stainless steel
CB/MCP Handle – Copper-free
aluminum
Reset Operator – Thermoplastic
polyester button molded onto stainless
steel shaft. Aluminum shroud.
Mounting Pan – Sheet aluminum
Hinge – Aluminum with stainless
steel pin
Reset Shroud – Black anodized
Features
Nema 4, 4X rated – providing protec-
tion from hose directed water and
corrosion
Universal mounting pan, pre-drilled
to facilitate easy field installation of
starters. Provision for grounding
supplied as standard.
More wiring room – meets latest NEC
wire bend requirements
Quick release, captivated cover bolts
of 316 grade stainless steel
Flange sealing gasket located to the
inside of cover bolt – preventing
water seepage into enclosure through
bolt holes
Hinged cover provided as standard
for an extra measure of safety and
convenience
Breaker (MCP) handle can be pad-
locked in “ON” or “OFF” position
Provisions provided for drain and
breather plus conduit openings for
power and control
Reset button provided as standard
Two control operator openings provid-
ed plugged as standard. Additional
openings can be factory or field
drilled.
Copper-free (less than 4/10 of 1%
copper) enclosure
Ductile mounting lugs
Catalog Logic
See page C48 for enclosures
with controls.
Line Starter Combination Starter
B7 SERIES CONTROLS
MAGNETIC MOTOR STARTERS
C44
FEATURES-SPECIFICATIONS
B7 MAGNETIC LINE STARTERS
0
0
0
0
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
NEMA
STARTER
SIZE
MOTOR
VOLTS
COIL
VOLTS1MAX. HP
CATALOG NUMBER
CUTLER-HAMMER
SERIES AN16
SQUARE D
SERIES 8536
ENCLOSURE ONLY
NO INTERIORS
120
240
480
600
120
240
480
600
120
240
480
600
120
240
480
600
120
240
480
600
SEP. CONTROL
230
460
575
SEP. CONTROL
230
460
575
SEP. CONTROL
230
460
575
SEP. CONTROL
230
460
575
SEP. CONTROL
230
460
575
3
5
5
7-1/2
10
10
15
25
25
30
50
50
50
100
100
B7011
B7011
B7012
B7013
B7014
B7010HB
B7010HG
B7010HK
B7010HM
B7011HB
B7011HG
B7011HK
B7011HM
B7012HB
B7012HG
B7012HK
B7012HM
B7013HB
B7013HG
B7013HK
B7013HM
B7014HB
B7014HG
B7014HK
B7014HM
B7010SB
B7010SG
B7010SK
B7010SM
B7011SB
B7011SG
B7011SK
B7011SM
B7012SB
B7012SG
B7012SK
B7012SM
B7013SB
B7013SG
B7013SK
B7013SM
B7014SB
B7014SG
B7014SK
B7014SM
Classified - File E83969
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
1See catalog logic page C48 for other standard coil voltages.
2Control transformers for use on Combination Starters Only. Will not fit into B701 Series of Non-
Combination Starters.
3See catalog page C48 for modifications and accessories to enclosure.
Magnetic Line Starters - 3 Pole,
3 Phase, Single Speed Non Revers-
ing 600 VAC Max, 60Hz
Square D or Cutler-Hammer motor
starters available as standard.
Heaters not included. See page
C49 to order.
Line Starter Combination Starter
B7 SERIES CONTROLS
MAGNETIC MOTOR STARTERS C45
C
ENCLOSURE
CAT. NUMBER
B7025A2
B7025A4
B7025C2
B7025C4
B7025G2
B7025G4
B7025S2
B7025S4
B7025W2
B7025W4
STARTER
MANUFACTURER
Allen Bradley
Allen Bradley
Cutler Hammer
Cutler Hammer
General Electric
General Electric
Square D
Square D
Westinghouse
Westinghouse
SIZE 5 COMBINATION MOTOR STARTER ENCLOSURE ONLY
STARTER
TYPE
Series 509
Series 509
Freedom-AN16
Freedom-AN16
Series 306
Series 306
Series 8536
Series 8536
Advantage
Advantage
C-H
J
K
J
K
J
K
J
K
J
K
GE
F-225
J-600
F-225
J-600
F-225
J-600
F-225
J-600
F-225
J-600
SQ-D
K
L
K
L
K
L
K
L
K
L
CIRCUIT BREAKER FRAME
B7 COMBINATION MAGNETIC LINE STARTERS
NEMA
STARTER
SIZE
MOTOR
VOLTS
COIL
VOLTS1MAX. HP ENCLOSURE ONLY
NO INTERIORS
120
120
120
240
240
480
480
480
600
600
600
120
120
240
480
600
120
120
240
240
480
600
120
240
480
600
120
240
480
600
120
120
240
240
480
480
600
600
SEP. CONTROL
SEP, CONTROL
SEP, CONTROL
230
230
460
460
460
575
575
575
SEP, CONTROL
SEP. CONTROL
230
460
575
SEP. CONTROL
SEP, CONTROL
230
230
460
575
SEP, CONTROL
230
460
575
SEP, CONTROL
230
460
575
SEP, CONTROL
SEP, CONTROL
230
230
460
460
575
575
1
3
1
2
5
1
2
5
7-1/2
10
10
15
15
25
25
30
50
50
50
100
100
75
100
150
200
150
200
CATALOG NUMBER
SQUARE D
SERIES 8536
DISCONNECT
TRIP
AMPS
CUTLER-HAMMER
SERIES AN16
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
2
2
2
2
2
2
3
3
3
3
4
4
4
4
5
5
5
5
5
5
5
5
3
7
15
7
15
3
7
15
3
7
15
15
30
30
30
30
50
70
50
70
50
50
100
100
100
100
150
150
150
150
250
400
250
400
250
400
250
400
B7020HBCA
B7020HBCB
B7020HBCC
B7020HGCB
B7020HGCC
B7020HKCA
B7020HKCB
B7020HKCC
B7020HMCA
B7020HMCB
B7020HMCC
B7021HBCC
B7021HBCF
B7021HGCF
B7021HKCF
B7021HMCF
B7022HBCK
B7022HBCM
B7022HGCK
B7022HGCM
B7022HKCK
B7022HMCK
B7023HBCQ
B7023HGCQ
B7023HKCQ
B7023HMCQ
B7024HBCT
B7024HGCT
B7024HKCT
B7024HMCT
B7025CBCMCPJ250
B7025CBCMCPK400
B7025CGCMCPJ250
B7025CGCMCPK400
B7025CKCMCPJ250
B7025CKCMCPK400
B7025CMCMCPJ250
B7025CMCMCPK400
B7020SBAA
B7020SBAB
B7020SBAC
B7020SGAB
B7020SGAC
B7020SKAA
B7020SKAB
B7020SKAC
B7020SMAA
B7020SMAB
B7020SMAC
B7021SBAC
B7021SBAF
B7021SGAF
B7021SKAF
B7021SMAF
B7022SBAK
B7022SBAM
B7022SGAK
B7022SGAM
B7022SKAK
B7022SMAK
B7023SBAQ
B7023SGAQ
B7023SKAQ
B7023SMAQ
B7024SBBT
B7024SGBT
B7024SKBT
B7024SMBT
B7025SBSMAGK250
B7025SBSMAGL400
B7025SGSMAGK250
B7025SGSMAGL400
B7025SKSMAGK250
B7025SKSMAGL400
B7025SMSMAGK250
B7025SMSMAGL400
B7021
B7021
B7022
B7023
B7024
See chart
below
Combination Starters
3-Pole, 3-Phase, Single
Speed Non Reversing
600 VAC Max, 60Hz
Square D or Cutler-
Hammer motor
starters and motor cir-
cuit protector avail-
able. Heaters not
included. See page
C49 to order.
Enclosure sized to
accommodate control
circuit transformer.
1See catalog logic page C48 for other standard coil voltages.
2Combination Starter enclosures provide sufficient space for factory of field mounting a control transformer.
3See catalog page C48 for modifications and accessories to enclosure.
Supplied with Cutler-Hammer
Advantage Starters
Applications
The PRISM® B7 Series of Combination
Starters are used for Motor Control and
Circuit protection of motors in
Hazardous And Hostile locations.
These Hazardous locations are typically
due to the presence of flammable
gases or vapors, combustible dust, or
easily ignitable fibers and flyings, and
areas which are subject to corrosion,
weather and dampness.
Advantage Starter Features
Solid-State Electronic Starter
Brownout Protection
Communications capabilities
Overload Heaters not required
Phase loss and phase unbalance
protection
Selectable automatic/manual reset
Class ll ground-fault protection
Enclosure Features
Nema 4, 4X rated – providing protec-
tion from hose directed water and
corrosion
Universal mounting pan, pre-drilled to
facilitate easy field installation of
starters. Provision for grounding sup-
plied as standard.
More wiring room – meets latest NEC
wire bend requirements
Quick release, captivated cover bolts
of 316 grade stainless steel
Classified - File E83969
Certified - File LR11714
See files for details or call Killark.
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
Flange sealing gasket located to the
inside of cover bolt – preventing
water seepage into enclosure
through bolt holes
Hinged cover provided as standard
for an extra measure of safety and
convenience
Breaker (MCP) handle can be pad-
locked in “ON” or “OFF” position
Provisions provided for drain and
breather plus conduit openings for
power and control
Field replaceable reset button pro-
vided as standard with gold contact
blocks
Two control operator openings
provided plugged as standard.
Additional openings can be factory
or field drilled
Copper-free (less than 4/10 of 1%
copper) enclosure
Ductile mounting lugs
Modifications & Accessories
Select from B7 Modification Chart on
page C48
Minimum Control Transformer
Size 1-2 100VA
Size 3-4 150VA
Size 5 300VA
Advantage Starters Auxiliary Contact
Modules
2NO/2NC = B7ADAC
Standard Materials
Enclosure – Copper-free aluminum
O-ring Gasket – BUNA-N nitrile
Cover Bolts – 316 grade stainless steel
CB/MCP Handle – Copper-free
aluminum
Reset Operator – Thermoplastic poly-
ester button molded onto stainless steel
shaft. Aluminum shroud.
Mounting Pan – Sheet aluminum
Hinge – Aluminum with stainless steel
pin
Reset Shroud – Black anodized
NEMA STARTER
SIZE
MOTOR
VOLTS
MAXIMUM
HP
COIL
VOLTS
FULL LOAD
AMPERAGE RANGE(1)
DISCONNECT
AMP TRIP
B7AD COMBINATION STARTER
1L
1
2
3
4
5
120/60
120/60
120/60
120/60
120/60
120/60
.47-4.14
3.15-27
3.15-45
9.9-90
9.9-133
38.3-270
230
460
575
230
460
575
230
460
575
230
460
575
230
460
575
230
460
575
1
2
2
7-1/2
10
10
15
25
25
30
50
50
50
100
100
100
200
200
3
7
15
30
50
100
150
400
WITH MOTOR PROTECTOR AND STARTER ENCLOSURE ONLY
B7AD02LH6CA
B7AD02LH6CB
B7AD02LH6CC
B7AD021H6CF
B7AD022H6CK
B7AD023H6CQ
B7AD024H6CT
B7AD025H6K400
B7AD021
B7ADO21
B7AD022
B7AD023
B7AD024
B7AD025K
CATALOG NUMBER
Notes: (1) Heaters are not required with the Advantage Starter. The Overload Module has trip current settings via DIP Switch
between the amperage range shown.
(2) All Advantage Starters are wired for separate control and must be controlled at the coil voltage shown. For 50 HZ applica-
tions a 110V 50 Hz coil is available. To order with this 50 Hz coil replace the number “6” in catalog number with “5”.
(3) Enclosures provide sufficient space for factory or field mounting a control transformer.
B7 SERIES CONTROLS
COMBINATION STARTERS
C46
ABC D E FG H I J K L M
62-1/4" 20-1/4" 15" 18-1/2" 43-1/2" 2-5/8" 3-1/8" 5-3/8" 7-3/8" 3-1/2 4" 1/2" 1"
(1581) (514) (381) (470) (1105) (67) (79) (137) (187) (89) (102) (13) (25)
Starter Only
Starter Only
Starter Only
Starter Only
Combination
Starter
Combination
Starter
Combination
Starter
Combination
Starter
B7 DIMENSIONS
11/2" conduit openings may be used for drain and/or breather installation. Smaller conduit openings may be used by utilizing reducing bushings.
Custom conduit sizes and locations are available upon request.
(457) (280) (232) (92) (416) (54) (60) (68) (87)
(508) (317) (232) (127) (467) (63) (63) (68) (81)
(667) (317) (276) (127) (625) (63) (70) (103) (140)
(870) (419) (292) (229) (830) (95) (102) (113) (152)
(584) (368) (232) (178) (543) (54) (64) (68) (87)
(648) (368) (232) (178) (606) (54) (64) (68) (87)
(692) (454) (280) (263) (651) (89) (89) (106) (140)
(870) (546) (302) (356) (829) (121) (127) (116) (157)
DIMENSIONS FOR SIZE 5 COMBINATION STARTER
DIMENSIONS CONDUIT TOP & BTM. (NPT) ENCL. WT.
(LBS.)
540
ABCDEFGH I POWER CONTROL
B7011 0,1 18" 11" 9-1/8" 3-5/8" 16-3/8" 2-1/8" 2-3/8" 2-11/16" 3-7/16" 46 1-1/2" 3/4" 1/2"
B7012 2 20" 12-1/2" 9-1/8" 5" 18-3/8" 2-1/2" 2-1/2" 2-11/16" 3-3/16" 56 1-1/2" 3/4" 1/2"
B7013 3 26-1/4" 12-1/2" 10-3/4" 5" 24-5/8" 2-1/2" 2-3/4" 4-1/16" 5-1/2" 80 2" 1" 1/2"
B7014 4 34-1/4" 16-1/2" 11-1/2" 9" 32-5/8" 3-3/4" 4" 4-7/16" 6" 155 3" 1" 1/2"
B7021 0,1 23" 14-1/2" 9-1/8" 7" 21-3/8" 2-1/8" 2-1/2" 2-11/16" 3-7/16" 78 1-1/2" 3/4" 1/2"
B7022 2 25-1/2" 14-1/2" 9-1/8" 7" 23-7¼8" 2-1/8" 2-1/2" 2-11/16" 3-7/16" 88 1-1/2" 3/4" 1/2"
B7023 3 27-1/4" 17-7/8" 11" 10-3/8" 25-5/8" 3-1/2" 3-1/2" 4-3/16" 5-1/2" 143 2" 1" 1/2"
B7024 4 34-1/4" 21-1/2" 11-7/8" 14" 32-5/8" 4-3/4" 5" 4-9/16" 6-3/16" 235 3" 1" 1/2"
Dimensions B7 Size 0 Thru 4 Dimensions B7 Size 5
B7 SERIES CONTROLS
MOTOR STARTERS DIMENSIONS C47
C
CATALOG
NUMBER
NEMA
SIZE TYPE
CATALOG
NUMBER
EST.
ENCLOLSRE
WEIGH
LBS.
DIMENSIONS CONDUIT OPENINGS
TOP/BOTTOM (IN.)1
TYPE
DRAIN
BREATHER
B7 SERIES CONTROLS
MOTOR STARTERS ACCESSORIES/CATALOG LOGIC
C48
B7
Starter Manufacturer
S—Square D
H—Cutler-Hammer (Freedom)
Starter Size
0
1
2
3
4
Starter Type
01—Non-Combination
(SSNR)
02—Combination
(SSNR)
Series
Constant
Catalog Logic – B7 Enclosures with Controls
Starter Coil Voltage
A—110V-60HZ
B—120/110V-60/50HZ
C—120/240V=60/50HZ
D—208/220V-60HZ
E—208/220/480V-60HZ
F—220V-60HZ
G—240/220V-50/60HZ
H—240/480V-60HZ
J—440/380V-60/50HZ
K—480/440V-60/50HZ
L—550V-60HZ
M—600/550V-60/50HZ
N—600V-50HZ
V—Specify Voltage
Disconnect
Current Rating
A—3 AMP
B—7 AMP
C—15 AMP
D—20 AMP
E—25 AMP
F—30 AMP
G—35 AMP
H—40 AMP
J—45 AMP
K—50 AMP
L—60 AMP
M—70 AMP
N—80 AMP
P—90 AMP
Q—100 AMP
R—110 AMP
S—125 AMP
T—150 AMP
U—175 AMP
V—200 AMP
W—225 AMP
X—250 AMP
Disconnect Means
A—Sq. D. FAL Mag Guard
B—Sq. D. KAL Mag Guard
C—Cutler-Hammer HMCP Motor C.R. Protector
D—Sq. D. FAL Thermal Magnetic
E—Sq. D. FHL Thermal Magnetic
F—Sq. D. FCL Thermal Magnetic
G—Sq. D. KAL Thermal Magnetic
H—Sq. D KHL Thermal Magnetic
J—Sq. D. KCL Thermal Magnetic
K—Cutler-Hammer EHD Thermal Magnetic
L—Cutler-Hammer FDB Thermal Magnetic
M—Cutler-Hammer FD Thermal Magnetic
N—Cutler-Hammer HFD Thermal Magnetic
P—Cutler-Hammer FDC Thermal Magnetic
B7 MODIFICATIONS AND ACCESSORIES
CATALOG NUMBER DESCRIPTION
SIZE 0 THRU 4 SIZE 5
B7DBP B7EDBP Double pushbutton (Start/Stop)
B7RPL B7ERPL Red pilot light 120 Volt
B7GPL B7EGPL Green pilot light 120 Volt
B7APL B7EAPL Amber pilot light 120 Volt
B7LPBR B7ELPBR Illuminated red pushbutton 120 Volt
B7LPBG B7ELPBG Illuminated green pushbutton 120 Volt
B7LPBA B7ELPBA Illuminated amber pushbutton 120 Volt
B7PLR220 B7PLR220 Pilot light resistor 220 Volt to 110 Volt
B7PLR440 B7PLR440 Pilot light resistor 440 Volt to 110 Volt
B7PLR550 B7PLR550 Pilot light resistor 550 Volt to 110 Volt
B72SS B7ESS 2 position selector switch ( On-Off )
B7SSHOA B7ESSHOA 3 position selector switch ( Hand-Off-Auto )
B7HAC B75CAC Cutler Hammer auxiliary contact (1NO/1NC)
B7SAC B75SAC Square D auxiliary contact (1NO/1NC)
B7TB B7TB Terminal block ( 6 Terminals )
B7IPR Interposing relay 120 Volt coil
B7CT50 — Control transformer 50VA (0,1,2)*
B7CT75 — Control transformer 75VA (0,1,2)*
* Control transformers are primary 240/480 - Secondary 120 Volt. Control
transformers for use on Combination Starters Only. Will not fit into
B701 Series of Non-Combination Starters.
* All control transformers include fused primary and secondary circuits.
** Installation of drains and breathers will void the NEMA4-4x ratings - voids Group B for CSA.
B7 MODIFICATIONS AND ACCESSORIES (CONTINUED)
CATALOG NUMBER DESCRIPTION
SIZE 0 THRU 4 SIZE 5
B7CT100 — Control transformer 100VA (0,1,2)*
B7CT150 — Control transformer 150VA (0,1,2)*
B7CT200 — Control transformer 200VA (3,4)*
B7CT250 — Control transformer 250VA (3,4)*
B7CT300 Control transformer 300VA (5)*
B7CT500 Control transformer 500VA (5)*
KB1B KB1B Breather** (not CSA)
KB1D KB1D Drain** (not CSA)
KIT-251 KIT-251 Grounding kit
B7SF B7SF Special finish - Baked epoxy outside
B7DLO B7DLO Delete lock “”ON”” feature for breaker handle
B7SH251 B7SH251 Space heater 25 Watt 120 Volt
B7SH252 B7SH252 Space heater 25 Watt 240 Volt
B7SH254 B7SH254 Space heater 25 Watt 480 Volt
B7SH501 B7SH501 Space heater 50 Watt 120 Volt
B7SH502 B7SH502 Space heater 50 Watt 240 Volt
B7SH504 B7SH504 Space heater 50 Watt 480 Volt
This Catalog Logic Chart is for reference only and is to be used for selection of special voltage and amperage requirements.
Consult Factory since not all assemblies are available with complete list of options displayed.
OVERLOAD HEATERS/NON-REVERSING CONTROLS
3-POLE, 60HZ, 600VAC SINGLE-SPEED C49
C
FOR SIZE 0-1 FOR SIZE 1 FOR SIZE 3 FOR SIZE 4
CATALOG
NUMBER
FULL-LOAD
CURRENT (AMPS)
NOTE: Square D 8536 series starters SSNR ambient compensated 20ÞC to 60ÞC block type overload using 3 heaters.
Three required for each starter.
Overload heaters are not
supplied as part of the
starter assemblies and are
to be ordered as separate
items by catalog number
and priced accordingly.
Heaters should be selected
on the basis of the actual
full-load current and service
factor as shown on the
motor nameplate or in the
manufacturer’s published lit-
erature.
When motor and overload
relay are in the same ambi-
ent and the service factor of
the motor is 1.15 to 1.25,
select heaters from the
heater selection chart. If
the service factor of the
motor is 1.0, or there is no
service factor shown, or a
maximum of 115% protec-
tion is desired, select one
size smaller heater than
indicated.
When motor and overload
relay are in different ambi-
ents, select heaters from the
chart using adjusted motor
currents as follows:
decrease rated motor cur-
rent 1% for each ÞC motor
ambient exceeds controller
ambient; increase rated
motor current 1% for each
ÞC controller ambient
exceeds motor ambient.
CATALOG
NUMBER
FULL-LOAD
CURRENT (AMPS)
CATALOG
NUMBER
FULL-LOAD
CURRENT (AMPS)
CATALOG
NUMBER
FULL-LOAD
CURRENT (AMPS)
CATALOG
NUMBER
MOTOR FULL-LOAD AMPERE RATING
DIAL POSITION
KB044
KB051
KB057
KB063
KB071
KB081
KB092
KB103
KB116
KBI30
KBI45
KB167
KB188
KB210
KB240
KB265
KB330
KB300
KB370
KB415
KB485
KB550
KB625
KB690
KB770
KB820
KB910
KB102
KB115
KB128
KB014
KB155
KB175
KB195
KB022
KB022
KB025
KB280
KB032
KB036
KB040
KB045
KB050
0.28-0.30
0.31-0.34
0.35-0.37
0.38-0.44
0.45-0.53
0.54-0.59
0.60-0.64
0.65-0.72
0.73-0.80
0.81-0.90
0.91-1.03
1.04-1.14
1.15-1.27
1.28-1.43
1.44-1.62
1.63-1.77
1.78-1.97
1.98-2.32
2.33-2.51
2.52-2.99
3.00-3.42
3.43-3.75
3.76-3.98
3.99-4.48
4.49-4.93
4.94-5.21
5.22-5.84
5.85-6.67
6.68-7.54
7.55-8.14
8.15-8.72
8.73-9.66
9.67-10.5
10.6-11.3
11.4-12.0
KB485
KB550
KB625
KB690
KB770
KB820
KB910
KB102
KB115
KB128
KB014
KB155
KB175
KB195
KB022
KB025
KB280
KB032
KB036
KB040
KB045
KB050
KB056
KB062
KB070
KB079
KB088
3.18-3.40
3.41-3.76
3.77-4.00
4.01-4.57
4.58-5.03
5.04-5.32
5.33-5.97
5.98-6.88
6.89-7.82
7.83-8.47
8.48-9.15
9.16-10.1
10.2-11.2
11.3-12.0
12.1-13.6
13.7-15.2
15.3-17.1
17.2-19.0
19.1-21.5
21.6-24.1
24.2-27.0
27.1-28.7
28.8-30.4
30.5-32.2
32.3-35.4
35.5-38.2
38.3-45.0
13.6-14.5
14.6-15.5
15.6-17.4
17.5-18.5
18.6-19.9
20.0-21.5
21.6-22.9
23.0-24.5
24.6-26.3
26.4-28.2
28.3-30.0
30.1-32.3
32.4-34.9
35.0-37.6
37.7-40.0
40.1-42.8
42.9-45.3
45.4-49.1
49.2-53.4
53.5-57.4
57.5-61.3
61.4-63.5.
63.6-66.3
66.4-69.0
69.1-70.9
71.0-73.7
73.8-76.5
76.6-78.4
78.5-86.0
KCC209
KCC228
KCC246
KCC263
KCC288
KCC310
KCC333
KCC364
KCC396
KCC427
KCC466
KCC501
KCC545
KCC594
KCC643
KCC685
KCC749
KCC815
KCC877
KCC940
KCC103
KCC112
KCC121
KCC132
KCC143
KCC156
KCC167
KCC180
KCC196
11.4-12.7
12.8-14.1
14.2-15.9
16.0-17.5
17.6-1 9.7
19.8-21.9
22.0-24.4
24.5-26.0
KH2001B-3
KH2002B-3
KH2003B-3
KH2004B-3
KH2005B-3
KH2006B-3
KH2007B-3
KH2008B-3
KH2009B-3
KH2010B-3
KH2011B-3
KH2012B-3
KH2013B-3
KH2014B-3
.254
.375
.560
.814
1.20
1.79
2.15
3.23
4.55
6.75
9.14
14.0
18.7
23.5
.306
.452
.676
.983
1.45
2.16
2.60
3.90
5.50
8.17
10.8
16.9
22.7
28.5
.359
.530
.791
1.15
1.71
2.53
3.04
4.56
6.45
9.58
12.4
19.9
26.7
33.5
.411
.607
.907
1.32
1.96
2.90
3.49
5.23
7.40
11.0
14.0
22.8
30.7
38.5
ABCD
KCC643
KCC685
KCC746
KCC815
KCC877
KCC940
KCC103
KCC112
KCC121
KCC132
KCC143
KCC156
KCC167
KCC180
KCC196
KCC208
KCC219
41.1-43.5
43.6-46.8
46.9-50.0
50.1-54.9
55.0-57.5
57.6-61.8
61.9-66.2
66.3-72.4
72.5-78.1
78.2-80.7
80.8-86.5
86.6-93.9
94.0-100
101.-112.
113.-117.
118.-123.
124.-133.
KDD112
KDD121
KDD128
KDD140
KDD150
KDD160
KDD185
KDD220
KDD240
KDD250
KDD265
KDD280
KDD300
KDD320
KDD320
82.5-88.2
88.3-95.9
96.0-102.
103.-109.
110.-121.
122.-139.
140.-154.
155.-163.
164.-175.
176.-184.
185.-195.
196.-215.
216.-224.
225.-243.
244.-266.
FOR SIZES 0-1
CATALOG
NUMBER
MOTOR FULL-LOAD AMPERE RATING
DIAL POSITION
KH2015B-3
KH2016B-3
KH2017B-3
29.0
39.6
53.9
34.0
45.5
60.9
39.1
51.5
67.9
44.1
57.4
74.9
KH2018-3
KH2019-3
KH2020-3
KH2021-3
KH2022-3
KH2023-3
KH2024-3
18.0
24.6
33.5
45.7
62.2
84.7
106.0
20.2
27.6
37.5
51.2
69.7
95.0
118.0
22.3
30.5
41.5
56.7
77.1
105.0
131.0
24.5
33.4
45.6
62.1
84.6
115.0
144.0
KH2004B-3
KH2005B-3
KH2006B-3
KH2007B-3
KH2008B-3
49
72
107
129
194
59
87
130
156
234
69
103
152
182
274
79
118
174
209
---
ABCD
FOR SIZE 2
FOR SIZES 3-4
FOR SIZE 5
FOR SIZE 2
FOR SIZE 5
SQUARE D 8536 SERIES STARTERS SSNR NEMA SIZES 0-1 THROUGH 5
CUTLER-HAMMER HEATER (EACH HEATER PACK CONSISTS OF 3 HEATERS)
Y7 SERIES CONTROLS
MOTOR STARTERS-MAGNETIC LINE STARTERS
C50
FEATURES-SPECIFICATIONS
Certified - File LR11714
Contact Killark for FM file numbers.
FM
APPROVED See files for details or call Killark.
Class I, Div. I & 2, Groups C,D
Class 1, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
Y7011ZH
Applications
Hazardous areas due to the pres-
ence of flammable gases or vapors,
combustible dusts or easily ignitable
fibers or flyings
Installations at petroleum refineries,
chemical and petrochemical plants,
storage areas and other processing
facilities where hazardous sub-
stances are handled or stored
Full-voltage, across-the-line starting
and stopping of polyphase AC squir-
rel cage induction motors or as the
primary starter for wound rotor
motors
Provides running and undervoltage
protection of motor
Remote starting and stopping of
motor
Features
Rectangular bolted cover design pro-
vides for attractive, compact, uniform
installations
Ground flange joint between box and
cover provides required flame path
Two drilled and tapped power con-
duit openings, one top and one bot-
tom are standard on all assemblies.
One 3/4"-14 NPT drilled, tapped and
plugged conduit opening is provided
in bottom for remote control
Two 3/4"-14 NPSM drilled, tapped,
and plugged openings in cover are
provided for addition of local control
operator
External reset button and stainless
steel cover bolts are standard
Hinges are either stainless steel or
aluminum and are mounted on the
left side of all assemblies
Enclosure is cast copper-free alu-
minum alloy
Available for Cutler-Hammer AN16
Freedom or Square D 8536 starters
Overload Heaters
Heaters not included. See page C49
for heater selection
Dimensions
See page C52 for dimensional data
Modifications
See page C52
Y7 MAGNETIC LINE STARTER
(ENCLOSURES WITHOUT SPACE FOR CONTROL TRANSFORMER)
Y7 MAGNETIC LINE STARTER
(ENCLOSURES WITH SPACE FOR CONTROL TRANSFORMER)
NEMA
STARTER MOTOR COIL MAXIMUM
SIZE VOLTS VO LTS HP
0 Sep Control 120
0 230 240 3
0 440-460 480 5
1 Sep Control 120
1 230 240 7-1/2
1 440-460 480 10
2 Sep Control 120
2 230 240 15
2 440-460 480 25
0 Enclosure only No interior
1 Enclosure only No interior
2 Enclosure only No interior
CUTLER-HAMMER SQUARE D
SERIES AN16 SERIES 8536
Y7010BH Y7010BS
Y7010DH Y7010DS
Y7010KH Y7010KS
Y7011BH Y7011BS
Y7011DH Y7011DS
Y7011KH Y7011KS
Y7012BH Y7012BS
Y7012DH Y7012DS
Y7012KH Y7012KS
Y7010ZH Y7010ZS
Y7011ZH Y7011ZS
Y7012ZH Y7012ZS
CATALOG NUMBER
NEMA
STARTER MOTOR COIL MAXIMUM
SIZE VOLTS VOLTS HP
0 230//460 120 3//5
1 230//460 120 7 1/2//10
2 230//460 120 15//25
0 Enclosure only No interior
1 Enclosure only No interior
2 Enclosure only No interior
CUTLER-HAMMER SQUARE D
SERIES AN16 SERIES 8536
Y7000BH Y7000BS
Y7001BH Y7001BS
Y7002BH Y7002BS
Y7000ZH Y7000ZS
Y7001ZH Y7001ZS
Y7002ZH Y7002ZS
CATALOG NUMBER
Y7 SERIES CONTROLS
COMBINATION MOTOR STARTERS C51
FEATURES-SPECIFICATIONS
C
Certified - File LR11714
Contact Killark for FM file numbers.
FM
APPROVED
See files for details or call Killark.
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
Y7021ZHAZ
Applications
Hazardous areas due to the
presence of flammable gases or
vapors, combustible dusts or
easily ignitable fibers or flyings
Full-voltage, across-the-line
starting and stopping of
polyphase AC squirrel cage
induction motors or as the pri-
mary starter for wound rotor
motors
Provides running and undervolt-
age protection of motor
Motor branch circuit disconnect
and short circuit protection
Features
Rectangular bolted cover design
provides for attractive, compact,
uniform installations
Two 3/4"-14 NPSM drilled,
tapped, and plugged openings
are provided for addition of local
operators
Two drilled, tapped and plugged
openings, one top and one bot-
tom are supplied for installation
of drain and breather
Hinges are either stainless steel
or aluminum and are mounted
on the left side of all assemblies
Circuit breaker handle mecha-
nism interlocks with circuit
breaker to prevent opening of
enclosure when circuit is in the
“ON” position
External handle is vault type with
standard provisions for locking in the
“OFF” position with up to three pad-
locks
Circuit breaker is trip free of handle
mechanism
Modifications
Modifications are available.
See page C52.
Dimensions
For dimensional data, see page C52.
Overload Heaters
Heaters are not included.
See page C49 for heater selection.
Y7 COMBINATION MAGNETIC LINE STARTER
NEMA DISCONNECT
STARTER MOTOR COIL MAXIMUM TRIP
SIZE VOLTS VOLTS HP AMPS
0 Sep Control 120 -3
0 Sep Control 120 -7
0 Sep Control 120 - 15
0 230 240 17
0 230 2 4 0 3 15
0 460 480 13
0 460 480 57
1 Sep Control 120 - 15
1 Sep Control 120 - 30
1 230 240 7-1/2 30
1 460 480 10 30
2 Sep Control 120 - 50
2 Sep Control 120 - 70
2 230 240 15 50
2 230 240 15 70
2 460 480 25 50
0 Enclosure only. No Interior
1 Enclosure only. No Interior
2 Enclosure only. No Interior
CUTLER-HAMMER SQUARE D
SERIES AN16 SERIES 8536
Y7020BHVV Y7020BSVV
Y7020BHVX Y7020BSVX
Y7020BHVA Y7020BSVA
Y7020DHVX Y7020DSVX
Y7020DHVA Y7020DSVA
Y7020KHVV Y7020KSVV
Y7020KHVX Y7020KSVX
Y7021BHVA Y7021BSVA
Y7021BHVC Y7021BSVC
Y7021DHVC Y7021DSVC
Y7021KHVC Y7021KSVC
Y7022BHVE Y7022BSVE
Y7022BHVG Y7022BSVG
Y7022DHVE Y7022DSVE
Y7022DHVG Y7022DSVG
Y7022KHVE Y7022KSVE
Y7020ZHVZ Y7020ZSVZ
Y7021ZHVZ Y7021ZSVZ
Y7022ZHVZ Y7022ZSVZ
CATALOG NUMBER
Y7 SERIES CONTROLS
MOTOR STARTERS/MODIFICATIONS
C52
FEATURES-SPECIFICATIONS
Combination Starter Modifications
Modifications are available by ordering the
following by catalog number as separate
items and noting on the order that they are
to be assembled into the enclosure.
NEMA CONDUIT SIZE
SIZE AB DEGHJ K
POWER CONTROL
0-117-3/4"(197) 7-1/4"(184) 10"(254) 6"(152) 2"(51) 7-5/8"(194) 1-1/8"(28) 3/4"(19) 1-1/2" 3/4"
219"(228) 7-3/4"(197) 11-1/4"(286) 6-1/2"(165) 2"(51) 7-5/8"(194) 1-1/8"(28) 7/8"(22) 1-1/2" 3/4"
0-128-3/4"(222) 11-1/8"(282) 12-1/2"(317) 10-1/2"(267) 2"(51) 8-1/4"(209) 2-3/8"(60) 2-3/8"(60) 1-1/2" 3/4"
228-3/4"(222) 11-1/8"(282) 12-1/2"(317) 10-1/2"(267) 2"(51) 8-1/4"(209) 2-3/8"(60) 2-3/8"(60) 1-1/2" 3/4"
Y7 MAGNETIC LINE STARTERS DIMENSIONS
Dimensions
NEMA CONDUIT SIZE
SIZE AB DEGHJ POWER CONTROL
0-1 16-1/4"(413) 11-1/8"(282) 20"(508) 10-1/2"(267) 2"(51) 9"(228) 2-3/8"(60) 1-1/2" 3/4"
2 16-1/4"(413) 11-1/8"(282) 20"(508) 10-1/2"(267) 2"(51) 9"(228) 2-3/8"(60) 1-1/2" 3/4"
Y7 COMBINATION STARTERS DIMENSIONS
1Without space for control transformer. 2With space for control transformer.
Y7 MODIFICATIONS AND ACCESSORIES
* Control transformers are primary 240/480 - Secondary 120 Volt.
* All control transformers include fused primary and secondary circuits.
CATALOG NUMBER
GO22-GR12D
GOB3-R23C N34
GOB3-G23C N34
GOB3-A23C N34
B7PLR220
B7PLR440
B7PLR550
GO25-2A3F
GO25-3C3G
B7HAC
B7SAC
B7CT50
B7CT75
B7CT100
KDB-1
KDB-1
KIT-251
DESCRIPTION
Double pushbutton (Start/Stop)
Red pilot light 120 Volt
Green pilot light 120 Volt
Amber pilot light 120 Volt
Pilot light resistor 220 Volt to 120 Volt
Pilot light resistor 440 Volt to 120 Volt
Pilot light resistor 550 Volt to 120 Volt
2 position selector switch (On/Off)
3 position selector switch (Hand/Off/Auto)
Cutler-Hammer auxiliary contact (1NO/1NC)
Square D auxiliary contact (1NO/1NC)
Control transformer 50VA*
Control transformer 75VA*
Control transformer 100VA*
Breather
Drain
Grounding kit
Magnetic Line Starters
Sizes 0, 1, 2
Combination Starters
Sizes 0, 1, 2
XSD/XSX/FXSD/FXSX SERIES CONTROLS
MANUAL MOTOR STARTING SWITCHES C53
FEATURES-SPECIFICATIONS
C
Listed - File E53360 and/or E12379
Certified - File LR11714
FM – File 25219
See files for details or call Killark.
FM
APPROVED
XSD, XSX, Series
Non Factory Sealed
FXSD, FXSX Series
Factory Sealed
Class I, Div. 1 & 2, Groups C,D
Class 1, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 7(C,D) 9(E,F,G)
NEMA 3 (Factory sealed type)
Applications
Provides manual starting and stop-
ping of small AC or DC motors
Motor running protection when over-
load heaters are used
XSX/FXSX Series (without overload
protection) are ideally suited for
across-the-line applications where a
positive disconnect means is
required
Features
FXSX-FXSD Series require no exter-
nal seals (factory sealed) and are
NEMA 3 (raintight) rated
Enclosures are cast copper-free
aluminum alloy
Operating shaft is stainless steel
Multiple gang assemblies available in
combination with pilot lights, push-
buttons and switches on request
Ground flange joint between bolted
cover and box provide required flame
path
Provisions for padlocking switch in
either “ON” or ”OFF” position is stan-
dard
Dimensions
For dimensional data, see page C54.
CATALOG NUMBER
1-POLE 2-POLE HUB HUB
SINGLE SINGLE STYLE SIZE
PHASE PHASE
XSD-11 XSD-12 Dead 1/2"
XSD-21 XSD-22 end 3/4"
XSD-41 XSD-42 Feed 1/2"
XSD-51 XSD-52 thru 3/4"
XSD-01 XSD-02 Cover and Switch assembly
XSD SINGLE GANG2
Non-Factory Sealed:
Square D, Class 2510, Type F
1-Pole, 1HP, 115-230 VAC
2-Pole, 1HP, 115-230 VAC
3/4 HP, 115-230 VDC
Factory Sealed:
Square D, Class 2510, Type F
1-Pole, 1HP, 115-230 VAC
2-Pole, 1HP, 115-230 VAC
3/4 HP, 115-230 VDC
1Order heaters separately on page C54.
2FM and CSA only
1FM and CSA only
XSD/FXSD SERIES WITH OVERLOAD PROTECTION1
Non-Factory Sealed:
Square D, Class 2510, Type K
2-Pole, 2 HP, 115 VAC
2 HP, 200-230 VAC
3 HP, 460-575 VAC
3-Pole, 2 HP, 115 VAC
7-1/2 HP, 200-230 VAC
10 HP, 460-575 VAC
Factory Sealed:
Square D, Class 2510, Type K
2-Pole, 2 HP, 115 VAC
2 HP, 200-230 VAC
3 HP, 460-575 VAC
3-Pole, 2 HP, 115 VAC
3 HP, 200-230 VAC
5 HP, 460-575 VAC
XSX/FXSX SERIES WITHOUT OVERLOAD PROTECTION
CATALOG NUMBER
2-POLE 3-POLE HUB HUB
30A., 250V 30A., 250V STYLE SIZE
20A., 600V 20A., 600V
1-PHASE 3-PHASE
XSX-12 XSX-13 Dead 1/2"
XSX-22 XSX-23 end 3/4"
XSX-42 XSX-43 Feed 1/2"
XSX-52 XSX-53 thru 3/4"
XSX-2 XSX-3 Cover and Switch assembly
XSX SINGLE GANG1
CATALOG NUMBER
2-POLE 3-POLE HUB HUB
30A., 250V 30A., 250V STYLE SIZE
20A., 600V 20A., 600V
1-PHASE 3-PHASE
FXSX12 FXSX13 Dead 1/2"
FXSX22 FXSX23 end 3/4"
FXSX42 FXSX43 Feed 1/2"
FXSX52 FXSX53 thru 3/4"
FXSX02 FXSX03 Cover and Switch assembly
FXSX SINGLE GANG
CATALOG NUMBER
1-POLE 2-POLE HUB HUB
SINGLE SINGLE STYLE SIZE
PHASE PHASE
FXSD11 FXSD12 Dead 1/2"
FXSD21 FXSD22 end 3/4"
FXSD41 FXSD42 Feed 1/2"
FXSD51 FXSD52 thru 3/4"
FXSD01 FXSD02 Cover and Switch assembly
FXSD SINGLE GANG
HEATER TABLE1
1Overload heaters are not supplied as part of the
starter assemblies and need to be ordered as
separate items by catalog number and priced
accordingly.
XSD/XSX NON-FACTORY SEALED DIMENSIONS
SQUARE D
FULL-LOAD HEATERCATALOG MOTOR CATALOGNUMBER CURRENT NUMBER
YOSD-A.49 0.41-0.44 A.49
YOSD-A.54 0.45-0.49 A.54
YOSD-A.59 0.50-0.53 A.59
YOSD-A.65 0.54-0.58 A.65
YOSD-A.71 0.59-0.65 A.71
YOSD-A.78 0.66-0.71 A.78
YOSD-A.86 0.72-0.78 A.86
YOSD-A.95 0.79-0.85 A.95
YOSD-A1.02 0.86-0.96 A1.02
YOSD-A1.16 0.97-1.04 A1.16
YOSD-A1.25 1.05-1.16 A1.25
YOSD-A1.39 1.17-1.29 A1.39
YOSD-A1.54 1.30-1.37 A1.54
YOSD-A1.63 1.38-1.47 A1.63
YOSD-A1.75 1.48-1.56 A1.75
YOSD-A1.86 1.57-1.65 A1.86
YOSD-A1.99 1.66-1.79 A1.99
YOSD-A2.15 1.80-1.95 A2.15
YOSD-A2.31 1.96-2.15 A2.31
YOSD-A2.57 2.16-2.38 A2.57
YOSD-A2.81 2.39-2.75 A2.81
YOSD-A3.61 2.76-2.84 A3.61
YOSD-A3.95 2.85-3.06 A3.95
YOSD-A4.32 3.07-3.45 A4.32
YOSD-A4.79 3.46-3.70 A4.79
YOSD-A5.30 3.71-4.07 A5.30
YOSD-A5.78 4.08-4.32 A5.78
YOSD-A6.20 4.33-4.90 A6.20
YOSD-A6.99 4.91-5.35 A6.99
YOSD-A7.65 5.36-5.85 A7.65
YOSD-A8.38 5.86-6.41 A8.38
YOSD-A9.25 6.42-6.79 A9.25
YOSD-A9.85 6.80-7.57 A9.85
YOSD-A11.0 7.58-8.15 A11.0
YOSD-A11.9 8.16-8.98 A11.9
YOSD-A13.2 8.99-9.67 A13.2
YOSD-A14.1 9.68-9.95 A14.1
YOSD-A14.8 9.96-10.8 A14.8
YOSD-A16.2 10.9-12.1 A16.2
YOSD-A17.9 12.2-13.1 A17.9
YOSD-A19.8 13.2-13.9 A19.8
YOSD-A21.3 14.0-15.0 A21.3
YOSD-A25.2 15.1-16.0 A25.2
BOX STYLE HUB SIZE ABDG
1/2" 5-1/4"(133) 2-1/4"(57) — 11/16"(17)
3/4" 5-1/4"(133) 2-1/4"(57) — 11/16"(17)
1" 5-3/8"(136) 2-3/8"(60) — 7/8"(22)
1/2" 5-1/4"(133) 2-1/4"(57) 6"(152) 11/16"(17)
3/4" 5-1/4"(133) 2-1/4"(57) 6"(152) 11/16"(17)
1" 5-3/8"(136) 2-3/8"(60) 6"(152) 7/8"(22)
FACTORY SEALED (FXSD/FXSX)
Single gang
dead-end
Single gang
feed-thru
XSD/XSX/FXSD/FXSX SERIES CONTROLS
XSD/XSX/FXSD/FXSX HEATERS
C54
FEATURES-SPECIFICATIONS
FEATURES-SPECIFICATIONS
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+H2, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
CCertified - File LR11714
US
Constant for Series
Enclosure Size
1 = B7EP
2 = B7EQ
Operating Device
R = Rotary
P = Push Buttons
Starter Manufacturer
to be supplied
S = Square D
A = ABB
Blank = Enclosure only
Horsepower (FLA) of starter
Accessories
A = Aux. Contacts NO + NC
B7MS 1 R S 1 A
Applications
The PRISM®B7MS Series of non-revers-
ing, manual line voltage starters and
enclosures are suitable for use in applica-
tions requiring manual across-the-line
starting and stopping of small single and
polyphase AC motors, and where over-
load protection is needed. Manual starters
are generally used on small machine
tools, fans and blowers, pumps, compres-
sors, and conveyors as well as many
other types of electrical equipment.
PRISM®enclosures universal design
accommodates, as standard, IEC starter
manufacturers including Square D, Cutler-
Hammer, ABB, Siemens, Moeller,
Sprecher + Schuh, Allen-Bradley,
Advance Controls, and WEG.
Square D © Schneider Electric
Siemens © Siemens AG
Moeller © Moeller Electric Corp.
See catalog pg. DE8A for copyrights of other
brands referenced.
When ordered with starters, ABB or
Square D supplied.
Features
Compact size enclosures provide
application flexibility with cost savings
over industry standard sizes
NEMA 4, 4X rated - providing pro-
tection from hose directed water and
corrosion
Pre-drilled to facilitate easy field
installation of starters
2 operating styles, rotary or push
button, including lock-out provision.
Provisions for drain and breather
Bi-directional ductile mounting lugs
Two NPT conduit openings provided
as standard, with custom openings
on request
Electrical Rating
Starters rated 600V, 3 phase up to 50HP
Standard Materials / Finish
Enclosures: Copper-free aluminum
(less than 4/10 of 1% copper content)
Cover Bolts: 316 Stainless Steel
O-ring Gasket: Silicone
Finish: Grey Powder Polyester painted
exterior, electrostatically applied
KIT-251 100 amp ground lug
AAuxiliary contacts 1 NO + 1 NC
SU-2 Hinge-9 Installed
SU3* Drain & Breather installed (NEMA 7CD)
SU3B* Drain & Breather installed (NEMA 7BCD)
B7SPNPT Change Std. conduit size and location
SU9 Special paint finish
SU14 Fungus proofing of enclosures
SUFFIX DESCRIPTION
NUMBER
*NOTE: The installation of a Drain & Breather will void the
NEMA 4-4X rating of enclosure.
MODIFICATIONS
Enclosure OUTSIDE BOX NOMINAL MOUNTING CONDUIT
DIMENSIONS INSIDE BOX DIMENSIONS SIZE
AB CDEFGHIJK -
B7MS1 5-3/4 8-1/16 6-5/16 3-5/8 5-13/16 5-1/16 3-1/8 8-1/8 --1-1/4 1
B7MS2 8-1/8 13-1/16 7-13/16 4-1/4 9-13/16 6-5/16 2-1/2 11-3/8 6-3/8 7-1/2 1-13/16 1-1/2
Catalog Logic
Fixed Lug Position For B7MS1
Optional Position For B7MS2
Standard Lug Position For B7MS2
DIMENSIONS
B7MS SERIES CONTROLS
COMPACT MANUAL IEC STARTERS C55
C
B7MS1P
Push Button Style
B7MS2R
Rotary Style
C56 B7MS SERIES • CONTROLS
COMPACT MANUAL IEC STARTERS
B7MS1R - For use with ABB
MS116, MS325, MS132
Automation Direct BM3
Cutler-Hammer XTPR
Moeller PKZMO
Seimens 3RV
Sprecher + Schuh KTA7
SQ D Telemecanique GV2P
WEG MPW25
B7MS2R - For use with
Automation Direct BM3
B7MS2RA - For use with ABB
MS450
B7MS1P - For use with
Cutler-Hammer XTPB
Moeller PKZMO1
SQ D Telemecanique GV2ME
WEG MPW25
B7MS2P - For use with
Advance Control MMS25
* B7MS1PRW - (enclosure
without starter) For use with
Allen-Bradley 140
Sorecher + Schuh KT4
B7MS - ROTARY STYLE WITH ABB MS132 & MS450 SERIES
CATALOG ADJUSTMENT SINGLE PHASE HP THREE PHASE HP
NUMBER RANGE FLA 120V 230V 200V-208V 230V 480V 600V
B7MS1RA-1 0.63 - 1.0 0.5 0.5
B7MS1RA-2 1.0 - 1.6 0.1 0.75 0.75
B7MS1RA-3 1.6 - 2.5 0.167 0.5 1 1.5
B7MS1RA-4 2.5 - 4.0 0.125 0.33 123
B7MS1RA-5 4.0 - 6.3 0.25 0.5 1.5 35
B7MS1R B7MS1RA-6 6.3 - 9.0 0.33 1 2.5 5 7.5
B7MS1RA-7 9.0 - 12.5 0.5 237.5 10
B7MS1RA-8 12.5 - 16.0 1 2.5 5 10 10
B7MS1RA-9 16.0 - 20.0 1.5 3510 15
B7MS1RA-10 20.0 - 25.0 23 7.5 15 20
B7MS2RA-12 11 - 16 135510 15
B7MS2RA-13 14 - 20 1.5 357.5 15 20
B7MS2RA-14 18 - 25 257.5 10 20 25
B7MS2RA-15 22 - 32 3510 10 25 30
B7MS2RA-16 28 - 40 3 7.5 15 15 30 40
B7MS2RA-17 36 - 45 5 7.5 15 15 30 40
B7MS2RA-18 40 - 50 5 10 15 20 40 50
B7MS - PUSH BUTTON STYLE SQUARE D GV2 SERIES
CATALOG ADJUSTMENT SINGLE PHASE HP THREE PHASE HP
NUMBER RANGE FLA 120V 230V 200V-208V 230V 480V 600V
B7MS1PS-1 0.63 - 1.0 0.5 0.5
B7MS1PS-2 1.0 - 1.6 0.1 0.75 1
B7MS1PS-3 1.6 - 2.5 0.167 0.5 0.5 1 1.5
B7MS1PS-4 2.5 - 4.0 0.125 0.33 0.75 123
B7MS1PS-5 4.0 - 6.3 0.25 0.5 1.5 1.5 35
B7MS1PS-6 6.0 - 10.0 0.5 1.5 23 57.5
B7MS1PS-7 9.0 - 14.0 0.75 23310 10
B7MS1PS-8 13.0 - 18.0 135510 15
B7MS1PS-9 17.0 - 23.0 1.5 357.5 15 20
B7MS1PS-10 20.0 - 25.0 2357.5 15 20
B7MS1PS-11 24.0 - 32.0 2510 10 20 30
B7MS2PS-12 10.0 - 16.0 123510 10
B7MS2PS-14 16.0 - 25.0 2357.5 15 20
B7MS2PS-16 25.0 - 40.0 3 7.5 10 10 25 30
B7MS2PS-18 40.0 - 63.0 5 10 20 20 40 50
ENCLOSURE
WITHOUT
STARTER
B7MS1R
ENCLOSURE
WITHOUT
STARTER
B7MS2RA
FOR USE
WITH ABB
ONLY
ENCLOSURE
WITHOUT
STARTER
B7MS1P*
ENCLOSURE
WITHOUT
STARTER
B7MS2P
B7MS - ROTARY STYLE WITH SQUARE D GV2 & GV3 SERIES
CATALOG ADJUSTMENT SINGLE PHASE HP THREE PHASE HP
NUMBER RANGE FLA 120V 230V 200V-208V 230V 480V 600V
B7MS1RS-1 0.63 - 1.0 0.5 0.5
B7MS1RS-2 1.0 - 1.6 0.1 0.75 1
B7MS1RS-3 1.6 - 2.5 0.167 0.5 0.5 1 1.5
B7MS1RS-4 2.5 - 4.0 0.125 0.33 0.75 123
B7MS1RS-5 4.0 - 6.3 0.25 0.5 1.5 1.5 35
B7MS1RS-6 6.0 - 10.0 0.5 1.5 23 57.5
B7MS1RS-7 9.0 - 14.0 0.75 23310 10
B7MS1RS-8 13.0 - 18.0 135510 15
B7MS1RS-9 17.0 - 23.0 1.5 357.5 15 20
B7MS1RS-10 20.0 - 25.0 2357.5 15 20
B7MS1RS-11 24.0 - 32.0 2510 10 20 30
ENCLOSURE
WITHOUT
STARTER
B7MS1R
ENCLOSURE
WITHOUT
STARTER
B7MS2R
C57
C
B7MS SERIES • CONTROLS
COMPACT MANUAL NEMA STARTERS
FEATURES-SPECIFICATIONS
Class I, Div. 1 & 2, Groups B,C,D
Class l, Zones 1 & 2, Groups llB+H2, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4, 4X, 7(B,C,D) 9(E,F,G)
B7MSN2P INTERNAL VIEW
CCertified - File LR11714
US
Applications
The PRISM®B7MSN Series of non-
reversing, manual line voltage starters
and enclosures are suitable for use in
applications requiring manual across-the-
line starting and stopping of small single
and polyphase AC motors, and where
overload protection is needed. Manual
starters are generally used on small
machine tools, fans and blowers, pumps,
compressors, and conveyors as well as
many other types of electrical equipment.
PRISM®enclosures universal design
accommodates, as standard, starter
manufacturers including
Allen-Bradley 609 Series
Cutler-Hammer B100M Series
GE CR106 Series
Square D 2510M Series
Allen Bradley © Rockwell Automation
Cutler-Hammer © Eaton Corporation
GE © General Electric Company
Square D © Schneider Electric
Features
Compact size enclosures provide
application flexibility with cost savings
over industry standard sizes
NEMA 4, 4X rated - providing pro-
tection from hose directed water and
corrosion
Pre-drilled to facilitate easy field
installation of starters
Large double green/red start-stop
push buttons
Can be pad locked in “OFF” position
Provisions for drain and breather
Bi-directional ductile mounting lugs
Two 1-1/2” NPT conduit openings pro-
vided as standard, with custom open
ings on request
Electrical Rating
NEMA starter sizes 0, 1, 1-1/2 FVNR;
2 pole single phase = 230 VAC
3 pole three phase = 600 VAC
2 pole VDC = 230 VDC
Overload Heaters
Heaters are not included, see next page.
Standard Materials /Finish
Enclosures: Copper-free aluminum
(less than 4/10 of 1% copper content)
Cover Bolts: 316 Stainless Steel
O-ring Gasket: Silicone
Finish: Grey Powder Polyester painted
exterior, electrostatically applied
** = INCLUDES 380VAC CH = CUTLER-HAMMER ONLY
KIT-251 100 amp ground lug
AO Aux. contact NO only
AC Aux. contact NC only
SU-2 Hinge-9 Installed
SU3* Drain & Breather installed (NEMA 7CD)
SU3B* Drain & Breather installed (NEMA 7BCD)
B7SPNPT Change Std. conduit size and location
SU9 Special paint finish
SU14 Fungus proofing of enclosures
SUFFIX DESCRIPTION
NUMBER
*NOTE: The installation of a Drain & Breather will void the
NEMA 4-4X rating of enclosure.
MODIFICATIONS
CATALOG NUMBER SIZE/PHASE SINGLE PHASE HP THREE PHASE DC HP
ENCLOSURE W/CUTLER-HAMMER W/SQUARE D 120VAC 230VAC 208VAC 230VAC 480VAC** 600VAC 115DC 230VDC
B7MSN2PC0B B7MSN2PS0B M-0 2P 12 1 CH 1.5 CH
B7MSN2PC1B B7MSN2PS1B M-1 2P 23 1.5 CH 2 CH
B7MSN2PSDB M-1P 2P 35
B7MSN2PC0C B7MSN2PS0C M-0 3P 33 5 5
B7MSN2PC1C B7MSN2PS1C M-1 3P 7.5 7.5 10 10
B7MSN2PS0V M-0 2P VDC 1 1.5
B7MSN2PS1V M-1 2P VDC 1.5 2
B7MSN2P
Optional Position
Standard Lug Position For B7MSN2P
Enclosure OUTSIDE BOX NOMINAL MOUNTING
DIMENSIONS INSIDE BOX DIMENSIONS
AB CDEFGHIJK
B7MSN2P 8-1/8 13-1/16 7-13/16 4-1/4 9-13/16 6-5/16 2-1/2 11-3/8 6-3/8 7-1/2 1-13/16
C58 B7MSN SERIES • CONTROLS
HEATERS, CATALOG LOGIC, DIMENSIONS
Catalog Logic
Constant for Series
Enclosure Size
2 = B7EQ
Operating Device
P = Push Buttons
Starter Manufacturer
C = Cutler-Hammer
S = Square D
Blank = Enclosure only
NEMA Size
O = Size Ø 1 = Size 1 D = Size 1-1/2
Number of Poles
B = 2 Pole 1 Ø (Cutler-Hammer, Sq.D only)
C = 3 Pole 3 Ø
V = 2 Pole DC
Accessories
AO = NO Aux. Contact AC = NC Aux. Contact
B7MSN 2 P C 1 B A
CATALOG
NUMBER
SINGLE
PHASE
THREE
PHASE
KB044
KB051
KB057
KB063
KB071
KB081
KB092
KB103
KB116
KB130
KB145
KB167
KB188
KB210
KB240
KB265
KB300
KB330
KB370
KB415
KB485
KB550
KB625
KB690
KB770
KB820
KB910
KB102
KB115
KB128
KB014
KB155
KB175
KB195
KB022
KB025
SIZE 1 & 1P
KB195
KB022
KB025
KB280
KB032
KB036
KB040
KB045
SIZE 1P
KB036
KB040
KB045
KB050
0.33 - 0.36
0.37 - 0.40
0.41 - 0.45
0.46 - 0.52
0.53 - 0.59
0.60 - 0.66
0.67 - 0.73
0.74 - 0.81
0.82 - 0.91
0.92 - 1.02
1.03 - 1.14
1.15 - 1.29
1.20 - 1.42
1.43 - 1.64
1.65 - 1.80
1.81 - 2.10
2.11 - 2.30
2.31 - 2.61
2.62 - 2.99
3.00 - 3.37
3.38 - 3.94
3.95 - 4.24
4.25 - 4.54
4.55 - 5.29
5.30 - 5.73
5.74 - 6.35
6.36 - 7.08
7.09 - 7.83
7.84 - 8.47
8.48 - 9.83
9.84 - 10.5
10.6 - 11.4
11.5 - 12.8
12.9 - 13.9
14.0 - 16.1
16.2 - 18.0
SIZE 1 & 1P
-----
-----
16.2 - 17.6
17.7 - 20.6
20.7 - 23.1
23.2 - 26.0
-----
-----
SIZE 1P
23.2 - 27.1
27.2 - 29.2
29.3 - 33.0
33.1 - 36.0
0.29 - 0.32
0.33 - 0.36
0.37 - 0.39
0.40 - 0.47
0.48 - 0.56
0.57 - 0.63
0.64 - 0.69
0.70 - 0.77
0.78 - 0.86
0.87 - 0.96
0.97 - 1.11
1.12 - 1.23
1.24 - 1.37
1.38 - 1.55
1.56 - 1.75
1.76 - 1.92
1.93 - 2.16
2.17 - 2.50
2.51 - 2.81
2.82 - 3.16
3.17 - 3.40
3.41 - 3.76
3.77 - 4.00
4.01 - 4.68
4.69 - 5.18
5.19 - 5.51
5.52 - 6.19
6.20 - 7.12
7.13 - 8.15
8.16 - 8.60
8.61 - 9.21
9.22 - 10.1
10.2 - 11.2
11.3 - 12.0
-----
-----
SIZE 1 & 1P
11.3 - 12.1
12.2 - 13.6
13.7 - 15.3
15.4 - 17.3
17.4 - 19.1
19.2 - 21.7
21.8 - 24.2
24.3 - 26.0
SIZE 1P
-----
-----
-----
-----
1Select heater element based on motor nameplate listed full load amps.
Trip rating of element is 125% of motor minimum F.L.A. listed for the element
B7MSN Heater Selection1
Square D 2510M Only
Motor Full Load AMPS @40oC
Size 0
B7MSN Heater Selections
CUTLER-HAMMER
XMSW SERIES • CONTROLS
MANUAL LINE STARTERS C59
FEATURES-SPECIFICATIONS
C
HEATER TABLE FOR XMSW SERIES MANUAL LINE STARTERS1
MOTOR FULL-LOAD
AMPS @ 40OCCUTLER
CATALOG SINGLE THREE HAMMER
NUMBER PHASE PHASE
YOWEA200-FH03 .28-.29 .25-.26 FH03
YOWEA200-FH04 .30-.33 .27-.29 FH04
YOWEA200-FH05 .34-.36 .30 .32 FH05
YOWEA200-FH06 .37-.40 .33-.35 FH07
YOWEA200-FH07 .41-.45 .36-.39- FH07
YOWEA200-FH08 .46-.50 .40-.44 FH08
YOWEA200-FH09 .51-.56 .45-.49 FH09
YOWEA200-FH10 .57-.63 .50-.55 FH10
YOWEA200-FH11 .64-.70 .56-.61 FH11
YOWEA200-FH12 .71-.78 .62-.68 FH12
YOWEA200-FH13 .79-.86 .69-.75 FH13
YOWEA200-FH14 .87-.95 .76-.83 FH14
YOWEA200-FH15 .96-1.04 .84-.91 FH15
YOWEA200-FH16 1.05-1.14 .92-1.00 FH16
YOWEA200-FH17 1.15-1.25 1.01-1.10 FH17
YOWEA200-FH18 1.26-1.39 1.11-1.22 FH18
YOWEA200-FH19 1.40-1.54 1.23-1.35 FH19
YOWEA200-FH20 1.55-1.71 1.36-1.50 FH20
YOWEA200-FH21 1.72-1.89 1.51-1.66 FH21
YOWEA200-FH22 1.90-2.10 1.67-1.84 FH22
YOWEA200-FH23 2.11-2.32 1.85-2.03 FH23
YOWEA200-FH24 2.33-2.54 2.04-2.23 FH24
YOWEA200-FH25 2.55-2.79 2.24-2.45 FH25
YOWEA200-FH26 2.80-3.07 2.46-2.69 FH26
YOWEA200-FH27 3.08-3.36 2.70-2.95 FH27
YOWEA200-FH28 3.37-3.68 2.96-3.23 FH28
YOWEA200-FH29 3.69-4.03 3.24-3.53 FH29
MOTOR FULL-LOAD
AMPS @ 40OCCUTLER
CATALOG SINGLE THREE HAMMER
NUMBER PHASE PHASE
YOWEA200-FH30 4.04-4.40 3.54-3.86 FH30
YOWEA200-FH31 4.41-4.81 3.87-4.22 FH31
YOWEA200-FH32 4.82 -5.26 4.23 -4.61 FH32
YOWEA200-FH33 5.27-5.74 4.62-5.03 FH33
YOWEA200-FH34 5.75-6.25 5.04-5.49 FH34
YOWEA200-FH35 6.27-6.83 5.50-5.99 FH35
YOWEA200-FH36 6.84-7.45 6.00-6.53 FH36
YOWEA200-FH37 7.46-8.11 6.54-7.11 FH37
YOWEA200-FH38 8.12 -8.81 7.12 -7.73 FH38
YOWEA200-FH39 8.82-9.58 7.74-8.40 FH39
YOWEA200-FH40 9.59-10.40 8.41-9.12 FH40
YOWEA200-FH41 10.41-11.3 9.13-9.89 FH41
YOWEA200-FH42 11.4-12.2 9.9-10.7 FH42
YOWEA200-FH43 12.3-13.5 10.8-11.8 FH43
YOWEA200-FH44 13.6-14.9 11.9-13.0 FH44
YOWEA200-FH45 15.0-16.0 13.1-14.0 FH45
YOWEA200-FH46 16.1-17.1 14.1-15.0 FH46
YOWEA200-FH47 17.2-18.3 15.1-16.1 FH47
YOWEA200-FH48 18.4-19.7 16.2-17.3 FH48
YOWEA200-FH49 19.8-21.2 17.4-18.6 FH49
YOWEA200-FH50 21.3-22.8 18.7-20.0 FH50
YOWEA200-FH51 22.9-24.5 20.1-21.5 FH51
YOWEA200-FH52 24.6-26.4 21.6-23.2 FH52
YOWEA200-FH53 26.5-28.5 23.2-25.0 FH53
YOWEA200-FH54 28.6-30.8 25.1-26.8 FH54
YOWEA200-FH55 30.9-33.3 — — FH55
YOWEA200-FH56 33.4-36.0 — — FH56
YOWEA200-FH57 36.1-38.9 — — FH57
1Heaters not included. If heaters are required order as separate item by catalog number, three
phase starters require three heaters. Single phase starters require two heaters.
2Three pole starters may be used on two-phase four-wire circuits by running one wire direct to motor.
XMSW MANUAL LINE STARTERS1 2
CUTLER HAMMER/EATON
B100 STARTERS FULL
VOLTAGE, NON-REVERSING
SINGLE AND POLYPHASE
Listed - File E12379
See files for details or call Killark.
Applications
XMSW Series, non-reversing, manual
line voltage starters and enclosures are
suitable for use in applications requiring
manual across-the-line starting and
stopping of small single and polyphase
AC motors, and where overload protec-
tion is needed. Manual starters are
generally used on small machine tools,
fans and blowers, pumps, compressors,
and conveyors as well as many other
types of electrical machinery.
Features
Rectangular bolted cover design
provides for attractive, compact,
uniform installations
Enclosure and external handle are
diecast copper-free (less than 0.4%)
aluminum alloy
Cast “ON,” “OFF,” “TRIPPED” markings
on cover align with external handle and
provide clear indication of enclosed
starter condition
External handle is a vault type with
standard provisions for locking in the
OFF” position with up to three
pad-locks. Provision for locking in
“ON” position is available as factory
modification (add suffix SU-40 to
catalog number).
Two cast 1" NPT conduit hubs with
integral pipe stop, one top and
one bottom, are standard on all
assemblies
Electrical Rating
Starter sizes 0, 1, 11/2
Two pole, single phase; three pole,
polyphase
Maximum 10 HP, 600 Volts AC
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB,
llA
Class II, Div. 1 & 2, Groups E,F,G
Class Ill
NEMA 3R, 7(C,D) 9(E,F,G)
NEMA NUMBER OF MAXIMUM HORSEPOWER
SIZE POLE SIZE 120 VAC 208-240 VAC 480-600 VAC
0 2-POLE; 1Ø, A C 1 2
0 3-POLE; 3Ø, A C 2 3 5
1 2-POLE; 1Ø, A C 2 3
1 3-POLE; 3Ø, A C 3 7-1/2 10
1-1/2 2-POLE; 1Ø, A C 3 5
CATALOG NUMBER
WITH ENCLOSURE
STARTER ONLY
XMSW-0BT
XMSW-0CT
XMSW-1BT XMSW-00T
XMSW-1CT
XMSW-DBT
1Select heater element based on motor
nameplate listed. Full-load amps.
Trip rating of element is125% of motor
minimum F.L.A. listed for the element.
Dimensions
Section L
Li
NV2 Series
Class I, Div.2; NEMA 4X
.........
2-5 XXX X
V Series
Standard Location
.................
6-8 X
Class I, Div. 2; NEMA 4
........
9-10 XXX
Accessories, Dimensions
....
11-13
DV Series
DV Dust Ignition Proof...................14 XX
NVPI Series
Wet Locations
Class II, Div. 2
Non-Metallic/Non-Glass
.............
15 XX X
EMI Series
Hazardous Location
NEMA 4X Groups C,D
60-300 Watt Incandescent
....
137-138 XX X X
E Series/H Series
Hazardous Location
Groups A,B
200-300 Watt Incandescent
....
16
H Series Replacement Parts
.....
16 XXX
XHL Series
Hazardous Location
Handlamps
100 Watt Incandescent
...........
14 X
INCANDESCENT
FIXTURES
COMPACT
FLUORESCENT
Wet / Damp Location (or N3)
NEMA 4 (or 4X, or IP6x)
Class I, Div. 2 / Zone 2
Class I, Zone 2 Ex nR (option)
Class I, Div. 2 / Zone I
Class II / III Div. 1
Class II / III Div. 2
Class I, Div. 1 C,D / Zone I
Class I, Div. 1 A,B,C,D / Zone I
CENELEC Zone 2
CENELEC Zone 1
Wet / Damp Location (or N3)
NEMA 4 (or 4X, or IP6x)
Class I, Div. 2 / Zone 2
Class I, Zone 2 Ex nR (option)
Class I, Div. 2 / Zone I
Class II / III Div. 1
Class II / III Div. 2
Class I, Div. 1 C,D / Zone I
Class I, Div. 1 A,B,C,D / Zone I
CENELEC Zone 2
CENELEC Zone 1
General Suitability —
See catalog pages for details
General Suitability —
See catalog pages for details
PRODUCT PAGE NO. PRODUCT PAGE NO.
NV2F Series
13-42 Watt Quad-Pin...............2-5 XXX X
NVPF Series
13-26 Watt
Class II, Div. 2
Non-Metallic/Non-Glass
..........
15 XX X
MBF Series
13-39 Watt for
Standard & Certain
Hazardous Locations
..........
22-23
Accessories ........................26-27 XXXX X
VQ1F/VQ2F Series
(Replaces VBF/VQF)
13-84 Watt for
Standard & Certain
Hazardous Locations..........43-50 XXX X
EBF/EQF Series
13-84 Watt for
Hazardous Location
........
137-138 XX X X
XHLF Series
Hazardous Location
Handlamps
26 Watt Fluorescent
................
14 XX
NWPFN Series
Surface Mount
Non-Metallic/Non-Glass
13-26 Watt
....................
206-207 XXX X
Section L
L
Lii
HID AND INDUCTION
FIXTURES
LED FIXTURES
Wet / Damp Location (or N3)
NEMA 4 (or 4X, or IP6x)
Class I, Div. 2 / Zone 2
Class I, Zone 2 Ex nR (option)
Class I, Div. 2 / Zone I
Class II / III Div. 1
Class II / III Div. 2
Class I, Div. 1 C,D / Zone I
Class I, Div. 1 A,B,C,D / Zone I
CENELEC Zone 2
CENELEC Zone 1
Wet / Damp Location (or N3)
NEMA 4 (or 4X, or IP6x)
Class I, Div. 2 / Zone 2
Class I, Zone 2 Ex nR (option)
Class I, Div. 2 / Zone I
Class II / III Div. 1
Class II / III Div. 2
Class I, Div. 1 C,D / Zone I
Class I, Div. 1 A,B,C,D / Zone I
CENELEC Zone 2
CENELEC Zone 1
General Suitability —
See catalog pages for details
General Suitability —
See catalog pages for details
PRODUCT PAGE PRODUCT PAGE
®
®
MB Series
Medium Base HID...............22,24-25 XXX X
Accessories......................................26-27
Temperature Data................................28
Photometrics ....................................29-35
Series
Medium Base HID.........................57-65 XXX X
Mogul Base HID .............................66-89 XXX X
Induction System .......................90-92 XX X X
Introduction ....................................51-56
Quick Locator Table ........................52
“3rd Hand” Accessories ...............53
Restricted Breathing.............................54 XXXX X
Food Optics..........................................55
Dark Sky..................................................56
Accessories....................................93-97
Temperature Data .................104-113
Dimensions...............................100-103
Photometrics ............................114-131
Cross Reference VM
to Certilite®V..........................................97
EM Series
Medium Base HID ...............137, 139 XX X X
Accessories .............................140-141
Temperature Data.................144-145
Photometric ..............................146-155
Cenelec Option................................144 XX X X X
EZ Series
Mogul Base HID....................156-159 XX X X
Accessories .............................160-162
Temperature Data
..................
164-165
Photometrics
..............................
166-171
Cenelec Option................................164 XX X X X
MBL Series
Compact LED
Introduction/Logic .. .. . .. . .. . .. .17 XXX X
Selection Grids .................18
Components/Accessories .. . ..19
Dimensions .....................20
Photometrics................20-21
VM1L Series
Reduced Profile LED
Introduction/Logic .. .. . .. . ..36-37 XXX X
Selection Grids . . .. . .. . ... ..38-39
Components/Accessories .. . ..40
Dimensions .....................41
Photometrics ................41-42
EML Series
Explosion-Proof LED
CLI, Div.1, CL II, Div. 1, N4X
Introduction/Logic .. .. . .. . .. . .132 XX X X
Selection Grids . ... ... ... . .. . .133
Components/Accessories .. .134
Dimensions ...................135
Photometrics .. . .. . ... ... .135-136
NVSL Series LED Signals
CLI, Div.2, CL II, Div. 1, N4X
Non-Metallic, Non-Glass . .216-218 XXX X
LED
TECHNOLOGY
Section L
Liii
Wet / Damp Location (or N3)
NEMA 4 (or 4X, or IP6x)
Class I, Div. 2 / Zone 2
Class I, Zone 2 Ex nR (option)
Class I, Div. 2 / Zone I
Class II / III Div. 1
Class II / III Div. 2
Class I, Div. 1 C,D / Zone I
Class I, Div. 1 A,B,C,D / Zone I
CENELEC Zone 2
CENELEC Zone 1
General Suitability —
See catalog pages for details
PRODUCT PAGE NO.
LINEAR FLUORESCENT
DBF Series
Fluorescent
Class l, Div. 2 .................172 XXX X
LZ2S Series
Fluorescent Stainless Steel .. .173 XXX X
LZ2N Series
Fluorescent Non-Metallic
Class I, Div. 2
Class II, Div. I .. . .. . .. . .. . .174-177 XXX X
HFX-T Series
BIAXIAL Fluorescent
Class I, Div. I .. .. . .. . .. . ..178-179 XX X X
HFX Series
Hazardous Location
Paint Spray Suitable .....180-185 XX X X
See L206-207
for emergency
backed models . . . . . . .206-207 XXX X
Wet / Damp Location (or N3)
NEMA 4 (or 4X, or IP6x)
Class I, Div. 2 / Zone 2
Class I, Zone 2 Ex nR (option)
Class I, Div. 2 / Zone I
Class II / III Div. 1
Class II / III Div. 2
Class I, Div. 1 C,D / Zone I
Class I, Div. 1 A,B,C,D / Zone I
CENELEC Zone 2
CENELEC Zone 1
General Suitability —
See catalog pages for details
EMERGENCY SIGNALING
STROBE LIGHTING
ESX
Strobe Class I, Div. 1 ... .214-215 XX X X
NVSL/NVSZ
LED and XENON
Non-Metallic, Non-Glass .216-218 XXX X
PRODUCT PAGE NO.
FLOODLIGHTS &
WALL MOUNT FIXTURES
KWP Series
Wallpack
for Class I, Div. 2 & N4 ..194-195 XXX
QL
Quartz Floods ... ... ... . ..186-187 X
KF Series
Floods Aluminum
Class I, Div. 2 Marine N4
150 to 1000 Watt .. .. . .. .189-191 XXX
KF-SS
MariGard Stainless
Class I, Div. 2 Marine N4
150-400 Watt .. .. . ... ... ..192-193 XXXX
EM/DM
Portable Floods . . .. . .. . .. . ... .188 XX X X
EZ-T Trunnion ...........196-197 XX X
Section L
L
Liv
FITTINGS & ADAPTERS
FKA & FHC ...................219 X
HOOK/LOOP .................219 X
FH HOOK .....................220 X
V Series
Fixture Hangers . ... . .. . .. . .. . .220 X
HXB & XFH ...................221 XXX
EKJ Series
Flexible Couplings . . .. . .. . ...221 XXXX
JL & JAL ......................222 XXX
ENY-2SET
Pendant Seals ................222 XXXX
VMCHVM
Adapter .......................223 XX XX X
EAC
Adapters ......................224 XX X X
Wet / Damp Location (or N3)
NEMA 4 (or 4X, or IP6x)
Class I, Div. 2 / Zone 2
Class I, Zone 2 Ex nR (option)
Class I, Div. 2 / Zone I
Class II / III Div. 1
Class II / III Div. 2
Class I, Div. 1 C,D / Zone I
Class I, Div. 1 A,B,C,D / Zone I
CENELEC Zone 2
CENELEC Zone 1
Wet / Damp Location (or N3)
NEMA 4 (or 4X, or IP6x)
Class I, Div. 2 / Zone 2
Class I, Zone 2 Ex nR (option)
Class I, Div. 2 / Zone I
Class II / III Div. 1
Class II / III Div. 2
Class I, Div. 1 C,D / Zone I
Class I, Div. 1 A,B,C,D / Zone I
CENELEC Zone 2
CENELEC Zone 1
General Suitability —
See catalog pages for details
General Suitability —
See catalog pages for details
PRODUCT PAGE NO.
PRODUCT PAGE NO.
EMERGENCY LIGHTING
BATTERY-BACKED
DE3B/DE4B ..................198
Class II, Div. 1
Exit Accessory .. . ... ... ... . .. 204 XX X
VE3B/VE4B
VE3Q/VE4Q
Class I, Div. 2/N4
Class ll/N4 .....................198 XXX X
Exit Accessory .. . ... ... ... . .. 204
EEQ
Class I, Div. 1 .................211 XXX
Exit Accessory ................211
EBB
Class I, D1/N3
Halogen Lamps ...............212 XXX
BATTERY OPTION
FLUORESCENT
DBFE
Linear Fluorescent
Class I, D2/N4 ................208 XXX X
LZ2NE/LZ2SE (FRP or SS)
Class I, Div. 2
Class II, Div. 2 ................209 XXX X
HFXE
Class I, Div. 1 .................210 XXX X X
T-codes @ 40°C Max; with or without Reflector
Min. supply wire Fluor. 60oC, Incan. 90oC
NV2 SERIES LIGHTING
NON-METALLIC CORROSION RESISTANT HAZARDOUS FIXTURES
L2
FEATURES-SPECIFICATIONS
See page L15 for
NVP Series
with Lexan®Globes
Pendant
Incandescent
Pendant
Fluorescent
Ceiling
Incandescent
Ceiling
Fluorescent
Class I, Div. 2, Groups A,B,C,D
Class l, Zone 2, Groups llC,llB,llA
Class II, Div. 2, Groups F,G
Class lII
Marine
NEMA 3, 4, 4X, IP66
ABS Type Approval
Certified - File LR11713
Applications
Designed specifically for corrosive & wet
NEMA 4X and hazardous environments.
Typical applications include manufactur-
ing plants, chemical and petrochemical
processing facilities, sewage treatment
plants, off-shore and dockside installa-
tions, agricultural, commercial/industrial,
mining and marine facilities.
Features
NV2 Series non-metallic light fixtures
combine an outstanding balance of
strength, stiffness, toughness and
electrical properties
Energy and labor saving fluorescent
or incandescent models
Accessories include polycarbonate
dome reflectors and wall extension
Molded from 30% glass-filled ther-
moset polyester for high strength
Resists corrosive effects of most
chemicals, hydrocarbons and
solvents
Designed for indoor and outdoor,
globe down applications.
to the following standards:
UL 1598 Standard for luminaires
UL 1598A Marine type luminaires
UL 844 Standard for lighting fixtures for
hazardous locations
CSA C22.2 no. 137-M1981 electric lumi-
naires for use in hazardous locations
Enclosed and gasketed
NEMA 3, 4X, IP66
Colored Globe Options**
Example: NV2IG15ASG-R for Ruby Standard Globe
or NV2IG15AHG-R for Ruby Tempered Globe
Suffix and available combinations
Color Standard Globe Tempered Globe
Amber AA
Blue BB
Ruby RR
Green G NA
Purple P NA
Blue- BG BG
Green
**Tempered globes are required for wet locations.
Pendant 3/4" Fixture w/clear Globe & Guard*
Type Standard Globe Tempered Globe
150A Incan.
13 W Fluor.
18 W Fluor.
26 W Fluor.
32 W Fluor.
42 W Fluor.
NV2IG15ASG
NV2FG13ASG
NV2FG18ASG
NV2FG26ASG
NV2FG32ASG
NV2FG42ASG
NV2IG15AHG
NV2FG13AHG
NV2FG18AHG
NV2FG26AHG
NV2FG32AHG
NV2FG42AHG
150A Incan.
13 W Fluor.
18 W Fluor.
26 W Fluor.
32 W Fluor.
42 W Fluor.
150A Incan.
13 W Fluor.
18 W Fluor.
26 W Fluor.
32 W Fluor.
42 W Fluor.
NV2IG15XSG
NV2FG13XSG
NV2FG18XSG
NV2FG26XSG
NV2FG32XSG
NV2FG42XSG
NV2IG15XHG
NV2FG13XHG
NV2FG18XHG
NV2FG26XHG
NV2FG32XHG
NV2FG42XHG
NV2IG15BSG
NV2FG13BSG
NV2FG18BSG
NV2FG26BSG
NV2FG32BSG
NV2FG42BSG
NV2IG15BHG
NV2FG13BHG
NV2FG18BHG
NV2FG26BHG
NV2FG32BHG
NV2FG42BHG
*Notes:
Tempered Globes are required for Wet
Location applications
All assemblies are unit packed with
required components (not assembled)
Fluorescent unit pack models (only) include
the lamp
Reflector is sold separately. For wall mount-
ing with reflector, the NVEXTG extension is
required and sold separately
Fluorescent models use “world voltage”
ballasts for 120VAC through 277VAC
50/60Hz applications
Incandescent models 277VAC max.
For M20 ceiling units change “X” in part #
to “M”. For wall units change “B” to “W”.
M20 Pendant not available.
Ceiling 3/4" Fixture w/clear Globe & Guard*
Type Standard Globe Tempered Globe
75A
100A
150A
13 Fluor
18 Fluor
26 Fluor
32 Fluor
42 Fluor
Class I Div.2 Class II Div.2 Minimum Start
Globe Type Clear Color Clear Color oCoF
Wall 3/4" Fixture w/clear Globe & Guard*
Type Standard Globe Tempered Globe
T2C
T2A
T2B
T3C
T3C
T3B
T3B
T2D
T2B
T2
T2
T3C
T3C
T3A
T3A
T2C
T3C
T3C
-
T4A
T4A
T4A
T4A
T4A
-
-
-
T4A
T4A
T4A
T4A
T4A
-
-
-
-20
-20
-20
-20
-20
-
-
-
-4
-4
-4
-4
-4
Fluorescent Operating Max. Amps
Type 120 VAC 277 VAC
13W Fluor .144 .067
18W Fluor .158 .073
26W Fluor .22 .097
32W Fluor .285 .128
42W Fluor .38 .166
NV2AG Pendant 3/4" NPT Pendant splice box includes a 316 stainless steel set screw at
the conduit connection
NV2XG1Ceiling 3/4" NPT
NV2MG1Box M20
NV2BG Wall Bracket Use with NV2XG or NV2MG for wall mount
1NV2 ceiling (wall) boxes have 4 10-32 brass inserts with 2 ground screws. May be used for wet locations, as
terminal/junction, boxes ,or instruments using ‘clear’ blank cover.
2See page L12 for colored globes; use tempered for wet locations.
NV2 SERIES LIGHTING
NON-METALLIC CORROSION RESISTANT HAZARDOUS FIXTURES L3
COMPONENT PARTS
L
ABS Type Approval
Class I, Div. 2, Groups A,B,C,D
Class l, Zone 2, Groups llC,llB,llA
Class II, Div. 2, Groups F,G
Class lII
Marine
NEMA 3, 4, 4X, IP66
Wall Mount
Incandescent
Pendent
Wall Mount
Fluorescent
Wall Mount with
Extension and Dome
Reflector accessories
Ceiling/Wall
Wall Elbow Ceiling/Wall
(Interior Detail)
Incandescent Fluorescent
Globe Guard
Reflector Extension
Gray Blank Clear
NV2 SPLICE BOXES - INCLUDES SILICONE GASKETS & BRASS SCREWS
CATALOG NUMBER DES C RIPTION
NV2 BODIES
CATALOG NUMBER DESCRIPTIO N
NV2IG15 Incandescent Body with E-26 medium base socket; fixture rated voltage 277VAC max.
NV2FG13 13 W Fluorescent Body World Voltage 120V - 277V 50/60Hz
NV2FG18 18 W Fluorescent Body World Voltage 120V - 277V 50/60Hz
NV2FG26 26 W Fluorescent Body World Voltage 120V - 277V 50/60Hz
NV2FG32 32 W Fluorescent Body World Voltage 120V - 277V 50/60Hz
NV2FG42 42 W Fluorescent Body World Voltage 120V - 277V 50/60Hz
NV2 GLASS GLOBES & GUARDS2
CATALOG NUMBER DESCRIPTIO N
VCG-100 Clear
VCGP-100 Clear, Tempered
NV2GG Guard
Ceiling
Box
150 watt Lamp size A-21 max.
NV2 REFLECTORS AND EXTENSION
CATALOG NUMBER DESCRIPTIO N
NVPSD12 White Polycabonate Reflector (secured by guard)
NVEXTG Extension (for wall mount fixture with reflector)
BLANK COVERS FOR NV2XG CEILING BOXES
CATALOG NUMBER DESCRIPTIO N
NV2CG Gray Cover
NV2CC1Clear Cover
NV2F FLUORESCENT REPLACEMENT LAMPS AND BALLASTS
MQL13 13 W Quad-Pin Lamp 900 Lumens
MQL18 18 W Quad-Pin Lamp 1200 Lumens
MQL26 26 W Quad-Pin Lamp 1800 Lumens
MQL32 32 W Quad-Pin Lamp 2400 Lumens
MQL42 42 W Quad-Pin Lamp 3200 Lumens
Ceiling box vol. 24 cu. inches
BKF131830 13/18 Watt Rep. Ballast
BKF26324230 26/32/42 Watt Rep. Ballast
Certified - File LR11713
NV2IG15 Incandescent
With Globe & Guard
Candlepower - 150 Watt
A-21 lamp 2850 lumens
For 75 Watt multiply by .42
For 100 Watt multiply by .61
NV2XG
5.19
(132)
Volume
24 Cu. In.
њ.33
TYP
(0)
NV2 SERIES LIGHTING
DIMENSIONS, CROSS REFERENCE, PHOTOMETRIC DATA
L4
Pendant
Dimensions* NV To NV2 Cross Reference Photometrics
Ceiling
Wall
Wall mount with optional reflector and with
extension. Extension required only for wall
mount units using reflector.
*NOTE: Dimensional diagrams show incan-
descent models, but include height also for
fluorescent.
11.20
Incandescent
(285)
12.31
Fluorescent
(340)
4.53 DIA.
(115)
11.69 DIA.
(297)
10.84
Incandescent
(275)
11.95
Fluorescent
(304)
4.75
(121)
12.26
Incandescent
(311)
13.37
Fluorescent
(340)
7.30
(185)
12.26 Incandescent
(311)
13.37 Fluorescent
(340)
13.78
(350)
Complete Fixtures
NVA15GG NV2IG15ASG INC 150W PEND STD GLOBE/GRD
NVA15GHG NV2IG15AHG INC 150W PEND TEMPER GLB/GRD
NVX15GG NV2IG15XSG INC 150W CEIL STD GLOBE/GRD
NVX15GHG NV2IG15XHG INC 150W CEIL TEMPER GLB/GRD
NVB15GG NV2IG15BSG INC 150W WALL STD GLOBE/GRD
NVB15GHG NV2IG15BHG INC 150W WALL TEMPER GLB/GRD
NVQA18GG NV2FG18ASG FL18 120-277 PEND STD GLOB/GRD
NVQA18GHG NV2FG18AHG FL18 120-277 PEND TEM GLOB/GRD
NVQX18GG NV2FG18XSG FL18 120-277 CEIL STD GLOB/GRD
NVQX18GHG NV2FG18XHG FL18 120-277 CEIL TEM GLB/GRD
NVQB18GG NV2FG18BSG FL18 120-277 WALL STD GLOB/GRD
NVQB18GHG NV2FG18BHG FL18 120-277 WALL TEM GLOB/GRD
Components
NVA NV2AG 3/4" Pendant
NVX NV2XG 3/4" Ceiling (Wall) Box
NVB NV2BG Elbow, use with Ceiling Box
NVQFC NV2FG18 Fluorescent Body 120-277VAC
50/60Hz
NVQFC184 (1) NV2FG18 Fluorescent Body 120-277VAC
50/60Hz
NVFC NV2IG15 Incandescent Body
NVFC-LT (2) NV2IG15 Incandescent Body
NVG NV2GG Guard
NVQ-18 MQL18 18W Compact Fluor. Lamp
NVBC NV2CG Blank Cover w/Two Gaskets
NVSG NV2CG Use Blank Covers extra gasket
(1) “4” for 277VAC Fluorescent no longer required
(2) Insulated socket incandescent no longer needed for 90c wire
Key New Features:
Certified for Hostile Locations: Class I Div 2;
Class II Div 2; N4X; IP66
ABS Approval
120-277VAC 50/60Hz World Voltage Ballasts on Fluorescents
Four new Fluorescent Wattages: 13, 26, 32, 42
Only 90° C wire for Incandescent suitable for Marine with 150A
New Dome Reflector
Colored “100” Series globes can be ordered in assemblies
M20 Metric ceiling/wall box
Four 10-32 bosses in ceiling box for user applications
Clear Blank covers available for user applications
Backward Compatability:
NVG & NV2GG are interchangeable
Globes are interchangeable
Old NV Incandescent and Fluorescent bodies will fit new
NV2 Boxes and Elbow, but assembly is Wet Location listed only
New NV2IG15 Incandescent will fit old NV Boxes and Elbow
New NV2FGx Fluorescent will fit old NVX box, not pendant
or elbow
Reflectors will fit old bodies for pendant or ceiling applications
OLD NEW# NEW DESCRIPTION
C US
% EFFECTIVE
FLOOR CAVITY
REFLECTANCE
0.20
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .79 .79 .79 .79 .74 .74 .74 .74 .64 .64 .64 .54.54 .54 .45 .45 .45 .41
1 .69 .64 .59 .55 .63 .59 .55 .51 .50 .47 .44 .41 .39 .37 .34 .32.30 .26
2 .61 .53 .47 .42 .56 .49.44 .39 .41 .37 .33 .34.31 .28 .27 .25 .23 .19
3 .55 .46 .39 .33 .50 .42.36 .31 .35 .30 .26 .29.25 .22 .23 .20 .18 .14
4 .49 .40 .33 .27 .45 .37.30 .25 .31 .26 .21 .25.21 .18 .20 .17 .14 .11
5 .45 .35 .28 .23 .41 .23.26 .21 .27 .22 .18 .22.18 .15 .18 .14 .12 .09
6 .41 .31 .24 .19 .38 .29.22 .18 .24 .19 .15 .20.16 .12 .16 .12 .10 .08
7 .38 .28 .21 .16 .35 .26.20 .15 .22 .17 .13 .18 .14 .11 .14 .11 .08 .06
8 .35 .25 .19 .14 .32 .23.17 .13 .20 .15 .11 .16.12 .09 .13 .10 .07 .06
9 .33 .23 .17 .12 .30 .21.15 .12 .18 .13 .10 .15.11 .08 .12 .09 .06 .05
10 .30 .21 .15 .11 .28 .19 .14 .10 .16 .12 .09 .14 .10 .07 .11 .08 .06 .04
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCRW
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING CRITERION = 2.3
TEST NO. 1716
1.15
(29)
5.37
(137)
2.12
(54)
1.15
(29)
1.15
(29)
NV2 SERIES LIGHTING
PHOTOMETRIC DATA L5
L
% EFFECTIVE
FLOOR CAVITY
REFLECTANCE
0.20
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .65 .65 .65 .65 .63 .63.63 .63 .60 .60 .60 .58.58 .58 .55 .55 .55 .54
1 .58 .56 .53 .51 .57 .54 .52 .50 .52 .50 .48 .50 .48 .47 .48 .47.45 .44
2 .53 .48 .43 .40 .51 .47.43 .40 .45 .41 .39 .43.40 .38 .41 .39 .37 .36
3 .47 .41 .36 .32 .46 .40.36 .32 .39 .35 .31 .37.34 .31 .36 .33 .30 .29
4 .43 .36 .31 .27 .42 .35.30 .27 .34 .29 .26 .32.29 .26 .31 .28 .25 .24
5 .39 .32 .26 .23 .38 .31.26 .22 .30 .25 .22 .29.25 .22 .28 .24 .12 .20
6 .36 .28 .23 .19 .35 .28.23 .19 .27 .22 .19 .26.22 .19 .25 .21 .19 .17
7 .33 .25 .20 .17 .32 .25.20 .17 .24 .20 .17 .23.19 .16 .23 .19 .16 .15
8 .31 .23 .18 .15 .30 .23.18 .15 .22 .18 .15 .27.17 .14 .21 .17 .14 .13
9 .29 .21 .16 .13 .28 .21.16 .13 .20 .16 .13 .19.16 .13 .19 .15 .13 .12
10 .27 .19 .15 .12 .26 .19 .15 .12 .18 .14 .12 .18 .14 .12 .17 .14 .12 .11
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCRW
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING CRITERION = 1.5
TEST NO. 1717
*Full cutoff distribution
*
*
Photometrics
NV2FG26 Fluorescent
With Globe & Guard
Candlepower - 26 Watt
CF26 lamp 1800 lumens
For 13 Watt multiply by .50
For 18 Watt multiply by .67
For 32 Watt multiply by 1.33
For 42 Watt multiply by 1.78
% EFFECTIVE
FLOOR CAVITY
REFLECTANCE
0.20
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .86 .86 .86 .86 .80 .80.80 .80 .69 .69 .69 .59.59 .59 .50 .50 .50 .46
1 .73 .68 .63 .58 .68 .63.58 .54 .53 .50 .47 .45.42 .39 .37 .35 .33 .29
2 .65 .57 .50 .44 .60 .52.46 .41 .44 .39 .35 .36.33 .29 .30 .27 .24 .20
3 .58 .48 .41 .34 .53 .44.38 .32 .37 .32 .27 .31.26 .23 .25 .21 .18 .15
4 .52 .42 .34 .28 .48 .38.31 .26 .32 .27 .22 .27.22 .18 .21 .18 .15 .12
5 .48 .37 .29 .23 .44 .34.27 .21 .28 .23 .18 .23.19 .15 .19 .15 .12 .09
6 .44 .32 .25 .19 .40 .30.23 .18 .25 .19 .15 .21.16 .13 .17 .13 .10 .08
7 .40 .29 .22 .16 .37 .27.20 .15 .22 .17 .13 .19 .14 .11 .15 .11 .08 .06
8 .37 .26 .19 .14 .34 .24.18 .13 .20 .15 .11 .17.12 .09 .14 .10 .07 .05
9 .34 .24 .17 .12 .32 .22.16 .11 .18 .13 .10 .15.11 .08 .12 .09 .06 .05
10 .32 .21 .15 .11 .30 .20.14 .10 .17 .12 .09 .14.10 .07 .11 .08 .06 .04
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCRW
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING CRITERION = 3.5
TEST NO. 1720
% EFFECTIVE
FLOOR CAVITY
REFLECTANCE
0.20
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .64 .64 .64 .64 .63 .63.63 .63 .60 .60 .60 .58.58 .58 .55 .55 .55 .54
1 .59 .56 .54 .52 .57 .55.53 .51 .53 .51 .49 .50.49 .48 .48 .47 .46 .45
2 .53 .48 .45 .41 .52 .47.44 .41 .45 .42 .40 .44.41 .39 .42 .40 .38 .37
3 .48 .42 .37 .34 .47 .41.37 .34 .40 .36 .33 .38.35 .32 .37 .34 .32 .31
4 .44 .37 .32 .28 .42 .36.32 .28 .35 .31 .28 .34.30 .27 .32 .29 .27 .26
5 .40 .33 .28 .24 .39 .32.27 .24 .31 .27 .23 .30.26 .23 .29 .26 .23 .22
6 .37 .29 .24 .21 .36 .29.24 .20 .28 .23 .20 .27.23 .20 .26 .23 .20 .19
7 .34 .26 .21 .18 .33 .26.21 .18 .25 .21 .18 .24.20 .18 .23 .20 .17 .16
8 .32 .24 .19 .16 .31 .24.19 .16 .23 .19 .16 .22.18 .16 .21 .18 .15 .14
9 .29 .22 .17 .14 .29 .22.17 .14 .21 .17 .14 .20.17 .14 .20 .16 .14 .13
10 .27 .20 .16 .13 .27 .20.16 .13 .19 .15 .13 .19 .15 .13 .18 .15 .12 .11
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCRW
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING CRITERION = 1.4
TEST NO. 1724
*Full cutoff distribution
NV2FG26 Fluorescent
With Globe, Guard & Reflector
Candlepower - 26 Watt
CF26 lamp 1800 lumens
For 13 Watt multiply by .50
For 18 Watt multiply by .67
For 32 Watt multiply by 1.33
For 42 Watt multiply by 1.78
NV2IG15 Incandescent
With Globe, Guard & Reflector
Candlepower - 150 Watt
A-21 lamp 2850 lumens
For 75 Watt multiply by .42
For 100 Watt multiply by .61
V SERIES WEATHERPROOF
INCANDESCENT COPPER-FREE ALUMINUM FIXTURES
L6
INTRODUCTION AND ORDERING INFORMATION
Listed - File E27731
Certified - File LR11851
Enclosed & Gasketed
CATALOG NUMBER
PENDANT MOUNT WITH VGA SPLICE BOX
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
FIXTURE
TYPE
100
200
LAMP
WATT
150
300
GUARD
(if selected)
VAG-100
VAG-100
VAG-200
VAG-200
FIXTURE
BODY
VFC-100
VFC-100
VFC-200
VFC-200
MOUNTING
BOX
VGA-1
VGA-2
VGA-1
VGA-2
CLEAR
GLOBE*
VCG-100
VCG-100
VCG-200
VCG-200
FIXTURE W/
GLOBE & GUARD
VUAGG-1-100 1
VUAGG-2-100 1
VUAGG-1-200 2
VUAGG-2-200 2
FIXTURE W/
GLOBE
VUAG-1-100 2
VUAG-2-100 2
VUAG-1-200 2
VUAG-2-200 2
CONSISTS OF
CATALOG NUMBER
CEILING MOUNT WITH VGX SPLICE BOX
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
FIXTURE
TYPE
100
200
LAMP
WATT
150
300
GUARD
(if selected)
VAG-100
VAG-100
VAG-200
VAG-200
FIXTURE
BODY
VFC-100
VFC-100
VFC-200
VFC-200
MOUNTING
BOX
VGX-1
VGX-2
VGX-1
VGX-2
CLEAR
GLOBE*
VCG-100
VCG-100
VCG-200
VCG-200
FIXTURE W/
GLOBE & GUARD
VUXGG-1-100 2
VUXGG-2-100 2
VUXGG-1-200 2
VUXGG-2-200 2
FIXTURE W/
GLOBE
VUXG-1-100 2
VUXG-2-100 2
VUXG-1-200 2
VUXG-2-200 2
CONSISTS OF
CATALOG NUMBER
CEILING MOUNT WITH FEET USING VBC SPLICE BOX AND VBA ADAPTER
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
FIXTURE
TYPE
100
200
LAMP
WATT
150
300
GUARD
(if selected)
VAG-100
VAG-100
VAG-200
VAG-200
FIXTURE
BODY
VFC-100
VFC-100
VFC-200
VFC-200
MOUNTING
BOX/ADAPTER
VBC-1+VBA
VBC-2 + VBA
VBC-1+VBA
VBC-2 + VBA
CLEAR
GLOBE*
VCG-100
VCG-100
VCG-200
VCG-200
FIXTURE W/
GLOBE & GUARD
VUXBGG-1-100 1
VUXBGG-2-100 1
VUXBGG-1-200 2
VUXBGG-2-200 2
FIXTURE W/
GLOBE
VUXBG-1-100 1
VUXBG-2-100 1
VUXBG-1-200 2
VUXBG-2-200 2
CONSISTS OF
CATALOG NUMBER
CEILING MOUNT WITH VGC SPLICE BOX - FEED THROUGH
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
FIXTURE
TYPE
100
200
LAMP
WATT
150
300
GUARD
(if selected)
VAG-100
VAG-100
VAG-200
VAG-200
FIXTURE
BODY
VFC-100
VFC-100
VFC-200
VFC-200
MOUNTING
BOX
VGC-1
VGC-2
VGC-1
VGC-2
CLEAR
GLOBE*
VCG-100
VCG-100
VCG-200
VCG-200
FIXTURE W/
GLOBE & GUARD
VUCGG-1-100 1
VUCGG-2-100 2
VUCGG-1-200 2
VUCGG-2-200 2
FIXTURE W/
GLOBE
VUCG-1-100 2
VUCG-2-100 2
VUCG-1-200 2
VUCG-2-200 2
CONSISTS OF
*For other colors, order globes and fixture components separately.
1Fixture supplied as component unit pack when ordered by this catalog number.
2Catalog number for ordering convenience; fixture is shipped as components as listed in catalog
number table.
V Series
Enclosed &
Gasketed
Applications
Locations requiring durable,
protected lighting fixtures
Wet and dirt laden locations
Industrial environments
requiring enclosed and gas-
keted (vapor tight) fixtures
Fixtures intended for base-up
mounting
Heat resistant glass globes
recommended for wet loca-
tions
Features
Electrostatically applied
epoxy/polyester finish
Modular design
Hubs are threaded for
attachment to conduit
Set screws in pendant fix-
tures
Copper-free aluminum (less
than 4/10 of 1%)
Class I, Div. 2, NEMA 4 mod-
els available - see VXFC
Series lighting assemblies
& components, pages L9-
L12. Dimensions page L13.
V SERIES WEATHERPROOF
INCANDESCENT COPPER-FREE ALUMINUM FIXTURES L7
ORDERING INFORMATION
L
Listed - File E27731
Certified - File LR11851
Enclosed & Gasketed
CATALOG NUMBER
CEILING MOUNT WITH VBA ADAPTER FOR ROUND OUTLET BOX
FIXTURE
TYPE
100
200
LAMP
WATT
150
300
HUB
SIZE
1/2"
3/4"
GUARD
(if selected)
VAG-100
VAG-200
FIXTURE
BODY
VFC-100
VFC-200
BOX
ADAPTER
VBA
VBA
CLEAR
GLOBE*
VCG-100
VCG-200
FIXTURE W/
GLOBE & GUARD
VOBG-100 1
VOBG-200 1
FIXTURE W/
GLOBE
VOB-100 1
VOB-200 2
CONSISTS OF
CATALOG NUMBER
CEILING MOUNT WITH VFPS ADAPTER FOR SQUARE OR OCTAGON OUTLET BOX
FIXTURE
TYPE
100
200
LAMP
WATT
150
300
HUB
SIZE
1/2"
3/4"
GUARD
(if selected)
VAG-100
VAG-200
FIXTURE
BODY
VFC-100
VFC-200
BOX
ADAPTER
VFPS
VFPS
CLEAR
GLOBE*
VCG-100
VCG-200
FIXTURE W/
GLOBE & GUARD
VFCAG-100 2
VFCAG-200 2
FIXTURE W/
GLOBE
VFCA-100 1
VFCA-200 2
CONSISTS OF
CATALOG NUMBER
CEILING MOUNT WITH VGH SPLICE BOX - DEAD END
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
FIXTURE
TYPE
100
200
GUARD
(if selected)
VAG-100
VAG-100
VAG-200
VAG-200
FIXTURE
BODY
VFC-100
VFC-100
VFC-200
VFC-200
MOUNTING
BOX
VGH-1
VGH-2
VGH-1
VGH-2
CLEAR
GLOBE*
VCG-100
VCG-100
VCG-200
VCG-200
FIXTURE W/
GLOBE & GUARD
VUHGG-1-100 2
VUHGG-2-100 2
VUHGG-1-200 2
VUHGG-2-200 2
FIXTURE W/
GLOBE
VUHG-1-100 2
VUHG-2-100 2
VUHG-1-200 2
VUHG-2-200 2
CONSISTS OF
CATALOG NUMBER
CEILING MOUNT WITH VXA DEEP 5-HUB SPLICE BOX
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
FIXTURE
TYPE
100
200
GUARD
(if selected)
VAG-100
VAG-100
VAG-200
VAG-200
FIXTURE
BODY
VFC-100
VFC-100
VFC-200
VFC-200
MOUNTING
BOX
VXA-1
VXA-2
VXA-1
VXA-2
CLEAR
GLOBE*
VCG-100
VCG-100
VCG-200
VCG-200
FIXTURE W/
GLOBE & GUARD
VXAGG-110 1
VXAGG-210 2
VXAGG-120 2
VXAGG-220 2
FIXTURE W/
GLOBE
VXAG-110 2
VXAG-210 2
VXAG-120 2
VXAG-220 2
CONSISTS OF
NOTES: Mounts directly to VJ ,VB or steel 3-1/2" or 4" outlet boxes. Supplied with gasket.
NOTES: Mounts directly to steel 4" square and 3-1/2" or 4" octagon outlet box. Supplied with gasket.
*For other colors, order globe and fixture components separately.
1Fixture supplied as component unit pack when ordered by this catalog number.
2Catalog number for ordering convenience; fixture is shipped as components as listed in catalog number table.
LAMP
WATT
150
300
LAMP
WATT
150
300
V SERIES WEATHERPROOF
INCANDESCENT COPPER-FREE ALUMINUM FIXTURES
L8
ORDERING INFORMATION
CATALOG NUMBER
STANCHION MOUNT FOR 1-1/4" THREADED PIPE
FIXTURE
TYPE
100
200
LAMP
WATT
150
300
HUB
SIZE
1-1/4"
1-1/4"
GUARD
(if selected)
VAG-100
VAG-200
FIXTURE
BODY
VFC-100
VFC-200
MOUNTING
ARM
VD-4
VD-4
CLEAR
GLOBE*
VCG-100
VCG-200
FIXTURE W/
GLOBE & GUARD
VD-410GG 1
VD-420GG 2
FIXTURE W/
GLOBE
VD-410G 1
VD-420G 2
CONSISTS OF
CATALOG NUMBER
WALL MOUNT WITH VB ELBOW TO MOUNT TO 4" OUTLET BOX
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
FIXTURE
TYPE
100
200
GUARD
(if selected)
VAG-100
VAG-100
VAG-200
VAG-200
FIXTURE
BODY
VFC-100
VFC-100
VFC-200
VFC-200
MOUNTING
ELBOW
VB-1
VB-2
VB-1
VB-2
CLEAR
GLOBE*
VCG-100
VCG-100
VCG-200
VCG-200
FIXTURE W/
GLOBE & GUARD
VFBGG-110 1
VFBGG-210 1
VFBGG-120 2
VFBGG-220 2
FIXTURE W/
GLOBE
VFBG-110 2
VFBG-210 2
VFBG-120 2
VFBG-220 2
CONSISTS OF
CATALOG NUMBER
WALL MOUNT WITH FEET USING VBC SPLICE BOX AND VB ELBOW
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
FIXTURE
TYPE
100
200
LAMP
WATT
150
300
LAMP
WATT
150
300
GUARD
(if selected)
VAG-100
VAG-100
VAG-200
VAG-200
FIXTURE
BODY
VFC-100
VFC-100
VFC-200
VFC-200
MOUNTING
BOX/ELBOW
VBC-1+VB-1
VBC-2+VB-2
VBC-1+VB-1
VBC-2+VB-2
CLEAR
GLOBE*
VCG-100
VCG-100
VCG-200
VCG-200
FIXTURE W/
GLOBE & GUARD
VFBGG-1-100 1
VFBGG-2-100 1
VFBGG-1-200 2
VFBGG-2-200 2
FIXTURE W/
GLOBE
VFBG-1-100 1
VFBG-2-100 1
VFBG-1-200 2
VFBG-2-200 2
CONSISTS OF
CATALOG NUMBER
WALL MOUNT-WITH VFL ELBOW FOR DIRECT MOUNT TO V SERIES SPLICE BOXES
FIXTURE
TYPE
100
200
LAMP
WATT
150
300
HUB
SIZE
GUARD
(if selected)
VAG-100
VAG-200
FIXTURE
BODY
VFC-100
VFC-200
MOUNTING
ELBOW
VFL
VFL
CLEAR
GLOBE*
VCG-100
VCG-200
FIXTURE W/
GLOBE & GUARD
VOBLG-100 1
VOBLG-200 2
FIXTURE W/
GLOBE
VOBL-100 2
VOBL-200 2
CONSISTS OF
Mounts directly to V Series splice boxes, not to VBC box.
Mounts directly to VJ or VB Series or 4" steel outlet boxes. One hub in back, supplied with gasket.
*For other colors, order globe and fixture components separately.
1Fixture supplied as component unit pack when ordered by this catalog number.
2Catalog number for ordering convenience; fixture is shipped as components as listed in catalog
number table.
Listed - File E27731
Certified - File LR11851
Enclosed & Gasketed
V SERIES LIGHTING
INCANDESCENT NEMA 4 - CLASS I, DIV. 2 ALUMINUM FIXTURES L9
FEATURES-SPECIFICATIONS
L
* Wet location when used with tempered glass.
Listed - File E10514
Certified - File LR11713
UL-1571 Standard for incandescent fixtures
UL-844 Standard for hazardous location fixtures
Class I, Div. 2, Groups A,B,C,D
Class I, Zone 2, Groups IIC,IIB,IIA
NEMA 3, 4*
1Suitability based on base up installation
APPLICATION DATA1
FIXTURE
TYPE
100
100
100
100
100
200
200
200
200
200
LAMP
SIZE
A-19
60W
A-19
70W
A-19
100W
A-21
100W
A-21
150W
A-23
150W
PS-25
150W
A-23
200W
PS-25
200W
PS-25
300W
GLOBE
TYPE
colored &
clear
colored &
clear
colored &
clear
colored &
clear
colored &
clear
colored &
clear
colored &
clear
colored &
clear
colored &
clear
colored &
clear
TEMPERATURE
CODE @ 40°C
T2C
(230°C)
T2D
(215°C)
T2A
(280°C)
T2B
(260°C)
T2
(300°C)
T2A
(280°C)
T2B
(260°C)
T2
(300°C)
T2A
(280°C)
(350°C)
See dimensions page L13.
Applications
Killark “V” Series Vaportight fixtures are
now available Third Party Certified for
use in certain hazardous as well as wet
locations which require durable, pro-
tected lighting fixtures.
Wet and dirt laden industrial environ-
ments such as walkways, tunnels,
loading docks, stairwells, etc. made
hazardous by the presence of flammable
vapors as defined by the NEC.
Fixtures intended for base-up mounting
only.
Heat resistant (tempered) glass globes
recommended for wet locations.
Features
Killark Vaportight assemblies using VXFC
bodies & tempered glass have all the
features & advantages of “V” Enclosed &
Gasketed” models plus:
Heavy-duty silicone gasketing for
NEMA 4 requirements
Third party tested & labeled for use
in C1D2 areas
Modular design permits selection of
splice box, fixture body, globe, guard
and reflector for specific or custom
applications
Existing V Series mounting boxes may
be retrofitted to upgrade to NEMA 4;
C1D2 suitability
Copper-free aluminum construction with
electrostatically applied epoxy/polyester
finish resists corrosion
Pendant
Ceiling
V SERIES LIGHTING
INCANDESCENT NEMA 4 - CLASS I, DIV. 2 ALUMINUM FIXTURES
L10
FEATURES-SPECIFICATIONS
CATALOG NUMBER
PENDANT MOUNT WITH VGA SPLICE BOX
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
FIXTURE
TYPE
100
200
GUARD
VAG-100
VAG-100
VAG-200
VAG-200
FIXTURE
BODY
VXFC-100 N34
VXFC-100 N34
VXFC-200 N34
VXFC-200 N34
MOUNTING
BOX
VGA-1
VGA-2
VGA-1
VGA-2
CLEAR
GLOBE*
VCGP-100
VCGP-100
VCGP-200
VCGP-200
FIXTURE W/
GLOBE & GUARD
VUAGG-1-100PX 1
VUAGG-2-100PX 1
VUAGG-1-200PX 1
VUAGG-2-200PX 1
CONSISTS OF
CATALOG NUMBER
CEILING FIXTURE WITH VGX SPLICE BOX
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
FIXTURE
TYPE
100
200
GUARD
VAG-100
VAG-100
VAG-200
VAG-200
FIXTURE
BODY
VXFC-100 N34
VXFC-100 N34
VXFC-200 N34
VXFC-200 N34
MOUNTING
BOX
VGX-1
VGX-2
VGX-1
VGX-2
CLEAR
GLOBE*
VCGP-100
VCGP-100
VCGP-200
VCGP-200
FIXTURE W/
GLOBE & GUARD
VUXGG-1-100PX 1
VUXGG-2-100PX 1
VUXGG-1-200PX 1
VUXGG-2-200PX 1
CONSISTS OF
CATALOG NUMBER
CEILING FIXTURE WITH MOUNTING FEET USING VBC SPLICE BOX & VBA ADAPTER
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
FIXTURE
TYPE
100
200
FIXTURE
BODY
VXFC-100 N34
VXFC-100 N34
VXFC-200 N34
VXFC-200 N34
MOUNTING
BOX/ADAPTER
VBC-1+VBA
VBC-2+VBA
VBC-1+VBA
VBC-2+VBA
CLEAR
GLOBE*
VCGP-100
VCGP-100
VCGP-200
VCGP-200
FIXTURE W/
GLOBE & GUARD
VUXBGG-1-100PX 1
VUXBGG-2-100PX 1
VUXBGG-1-200PX 1
VUXBGG-2-200PX 1
CONSISTS OF
*For other colors, order globes and mounting components separately.
1Fixture supplied as component unit pack when ordered by this catalog number.
2See page L9 for temperature codes; NEMA 3, 4 when used with tempered glass.
CATALOG NUMBER
WALL FIXTURE WITH MOUNTING FEET USING VBC SPLICE BOX & VB ELBOW
HUB
SIZE
1/2"
3/4"
1/2"
3/4"
FIXTURE
TYPE
100
200
GUARD
VAG-100
VAG-100
VAG-200
VAG-200
FIXTURE
BODY
VXFC-100 N34
VXFC-100 N34
VXFC-200 N34
VXFC-200 N34
MOUNTING
BOX/ELBOW
VBC-1 + VB-1
VBC-2 + VB-2
VBC-1 + VB-1
VBC-2 + VB-2
CLEAR
GLOBE*
VCGP-100
VCGP-100
VCGP-200
VCGP-200
FIXTURE W/
GLOBE & GUARD
VFBGG-1-100PX 1
VFBGG-2-100PX 1
VFBGG-1-200PX 1
VFBGG-2-200PX 1
CONSISTS OF
Listed - File E10514
Certified - File LR11713
UL-1571 Standard for incandescent fixtures
UL-844 Standard for hazardous location fixtures
Class I, Div. 2, Groups A,B,C,D2
Class I, Zone 2, Groups IIC,IIB,IIA
NEMA 3, 4
GUARD
VAG-100
VAG-100
VAG-200
VAG-200
LAMP
WATT
150
300
LAMP
WATT
150
300
LAMP
WATT
150
300
CATALOG NUMBER
STANCHION MOUNT FOR 1-1/4" THREADED PIPE
HUB
SIZE
1-1/4"
1-1/4"
FIXTURE
TYPE
100
200
FIXTURE
BODY
VFC-100 N34
VFC-200 N34
MOUNTING
BOX/ADAPTER
VD-4
VD-4
CLEAR
GLOBE*
VCGP-100
VCGP-200
FIXTURE W/
GLOBE & GUARD
VD-410GGPX 1
VD-420GGPX 1
CONSISTS OF
GUARD
VAG-100
VAG-200
LAMP
WATT
150
300
LAMP
WATT
150
300
V SERIES LIGHTING
COMPONENT PARTS/ACCESSORIES INCANDESCENT FIXTURES L11
L
VFC Fixture Bodies
Fixture bodies contain lamp receptacle
and are threaded to accept globes,
guards and reflectors. These fixture
bodies are designed for metallic boxes
and mount directly to V Series splice
boxes. They may also be mounted to VJ
Series, VB Series or other 4" outlet
boxes with the use of the appropriate
adapter plate. Each fixture body is
supplied with gaskets.
Listed - File E27731
Certified - File LR11851
V Splice Boxes
For use with types 100 and 200
fixture bodies
VFC-100
VXFC-1001
VGA
VGC
VXA
VGX
VB VD
VFL
CATALOG NUMBER HUB SIZE & QTY.
VGA-1 1/2"
VGA-2 3/4"
VGH-1 1/2"
VGH-2 3/4"
VGC-1 1/2"
VGC-2 3/4"
VGX-1 1/2"
VGX-2 3/4"
VXA-1 1/2"
VXA-2 3/4"
VBC-1* 1/2"
VBC-2* 3/4"
VXAB _
V SPLICE BOXES
DESCRIPTION
Pendant mount
Ceiling mount
Ceiling mount
Ceiling mount
Ceiling mount, deep box
Ceiling mount, with 3 close-up plugs (requires VBA Adapter)
Blank close-up plate (less gasket)
CATALOG NUMBER HUB SIZE QTY.
VB-1 1/2"
VB-2 3/4"
VFL
VD-4 1-1/4"
V MOUNTING BRACKETS
DESCRIPTION
Wall mount to VJ or VB boxes
Wall mount to VJ or VB boxes
Wall mount to V boxes directly or to VJ, VB boxes with VBA adapter
Stanchion mount
CATALOG NUMBER
VFC-100
VFC-200
VXFC-100 N34
VXFC-200 N34
V FIXTURE BODIES
DESCRIPTION
150W max. Enclosed & Gasketed Fixture Boby
300W max. Enclosed & Gasketed Fixture Boby
150W max. NEMA 3,4 - Class I, Div. 2 Fixture Body1
300W max. NEMA 3,4 - Class I, Div. 2 Fixture Body1
1Use VXFC body with tempered globe for NEMA 3, 4 - Class I, Div. 2 applications. VXFC body is
Class I, Div. 2 only (not N3, N4) when used with standard globes. Consult temperature table, page
L9 for suitability.
* Volume cu. in. is 18.
VBC
VBA
VFPS
V ADAPTER MOUNTING PLATES
Adapts fixture body to VB, VJ or steel 3-1/2" & 4" splice boxes. Supplied with gasket.
Adapts fixture body to steel 4" square outlet boxes or 3-1/2" or 4" octagon boxes
VBA VFPS
VGH
VFC-200
VXFC-2001
1
1
1
1
2
2
4
4
5
5
4
4
_
1
1
1
CATALOG NUMBER DESCRIPTION
V SERIES LIGHTING
COMPONENT PARTS/ACCESSORIES INCANDESCENT FIXTURES
L12
150 W A-21 LAMP
VCG-100
VCGP-100
VCGPT-100
VAMG-100
VAMGP-100
VGG-100
VGGP-100
VRG-100
VRGP-100
VRSG-100
VPG-100
300 W PS-25 LAMP
VCG-200
VCGP-200
VAMG-200
VGG-200
VGGP-200
VRG-200
VRGP-200
V GLASS GLOBES
CATALOG NUMBER
500 W PS-35 LAMP
75 W A-19 LAMP
VPLCG-100
150 W A-21 LAMP
VPLCG-200
VCG-500
VCGP-500
CATALOG NUMBER
VAG-100
VAG-200
V GUARDS
DESCRIPTION
100 Series Vaportite guard
200 Series Va p o r tite guard
VPRSD-100
VPRSD-200
V REFLECTORS
100 Series Reflector 16 3/8" Dia. 5 5/8" High. White polypropylene for pendant & ceiling
200 Series Reflector applications. Not for use with wall or stanchion models.
V SERIES GASKETS
Fixture body to splice box
Silicone, Fixture body to splice box
Replacement Gaskets for VB-1/VB-2 and VBA
Globe gasket
Silicone, globe gasket
VRME
V LAMP SOCKET
For fixture types 100 and 200
Listed - File E27731
Certified - File LR11851
150 W Max.
Lamp Size A-21
Polycarbonate 500 W Max.
Lamp Size PS-35
Globe Gasket
100 Series Standard - 15871AABB
200 Series Standard - VTGG (pictured)
100 Series Silicone - VTGG1-S
200 Series Silicone - VTGG2-S
300 W Max.
Lamp Size PS-25
VBG-100
VBGP-100 —
1Recommended for use with VXFC fixture basis.
2TM Thomas Manufacturing.
CATALOG NUMBER
CATALOG NUMBER
TYPE DESCRIPTION
DESCRIPTION
100 SERIES 200 SERIES
15871AABB VTGG
VTGG1-S VTG G2-S
VTG
VTG-S
VBNB
CATALOG NUMBER DESCRIPTION
VFC
VXFC
VFC
VFXC
DESCRIPTION
Clear
Clear Tempered. Thermal and shock resistant1
Clear Tempered with Tuffskin®coating2
Amber
Amber Tempered1
Blue Green
Blue Green Tempered1
Blue
Blue Tempered1
Ruby
Ruby Tempered1
Green
Purple
Polycarbonate. Cannot be used with guard or in high ambient
temperature locations (40°C/104°F max.) Not UL Listed.
Clear (for replacement) Formerly DCG-20
Tempered. Thermal and shock resistant (for replacement).
Body To Splice Box
Gasket
100 or 200 Series
VTG Standard
VTG-S Silicone (pictured)
V SERIES LIGHTING
DIMENSIONS L13
L
VGC VGX
V Stanchion
V Fixture
w/o Splice Box
VGH
VGA
VBC-1 & VBC-2
VXA
V Fixture
Globes
VFL
VB
5"
hole
.28"dia.
(11)
DV/XHL/XHLF SERIES LIGHTING
SPECIAL APPLICATION INCANDESCENT FIXTURES AND HAND LAMPS
L14
FEATURES-SPECIFICATIONS
DV DUST-IGNITION PROOF
Dimensions
Applications
For hazardous locations where sus-
pended metal, carbon (coal, etc.)
and grain dusts create explosive or
ignitable mixtures with the air
Features
Cast of corrosion resistant aluminum
alloy with electrostatically applied
epoxy/polyester finish
Ceiling mounted units supplied with
4 hubs.
LAMP HUB
SIZ E PENDANT CEILI NG
100 Watt A-21 1/2" DVA-110 DVX-110
150 Watt A-23 3/4" DVA-210 DVX-210
150 Watt PS-25 1/2" DVA-120 DVX-120
200 Watt PS-25 3/4" DVA-220 DVX-220
DV 100/200
FIXTURE
GLASS WIRE REPLACEMENT
TYPE
GLOBE GUARD SOCKET
100 DCGE-10 DAG-100 VRME
200 DCGE-20 DAG-200 VRME
ACCESSORIES/REPLACEMENT PARTS
MODEL
SIZE
TYPE
100
TYPE
200
Ceiling 100-200
Pendant 100-200
Class II, Div. 1 & 2 Groups E,F,G1
Class III
CATALOG NUMBER
CATALOG NUMBER
Listed - File E12976
Certified - File LR11713
1Temperature code T3B, use supply wire
suitable for 150° C.
DAG Guard
XHL
XHLF
XHL SERIES HAND LAMPS
Features XHLF Fluorescent (120 VAC)
No exposed metal parts
Furnished with 26 watt 1800 Lumen
fluorescent lamp and light shield
Supplied with grommet for use with
16/3 user furnished SO cable
Listed File No. E97760
XHLF Fluorescent
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB,llA
Class lI, Div. 1 & 2, Groups F,G
XHLF26 Fluorescent hand lamp
XHLF26-50KP
Fluorescent hand lamp with
- 50' of 16/3 SOW cord and
15A Acceptor plug
Features XHL Incandescent
Phenolic handle for long service in
rugged conditions
Aluminum guard
Heat and impact resistant globe
Supplied with an A-21 100 Watt
(100A/RS) Rough Service lamp
Supplied with 2 grommets for use
with either 14/3 or 16/3 user fur-
nished SO cable
XHL-100
XHL-GL
XHLG
XHLS
Handlamp
Replacement Globe
Replacement Guard
Replacement Socket
CATALOG NUMBER DESCRIPTION
XHL Incandescent
Class I, Div. 1 & 2, Groups C, D
Class I, Zones 1 & 2, Groups llB,llA
Listed File No. E97760
Certified File No. LR10019
CATALOG NUMBER
XHL Series Hand Lamps are a handy accessory to the ACCEPTOR®Series. Used
as a supplemental illumination source for areas where flammable materials are
present such as processed finished goods, storage vats or handling areas.
c
DESCRIPTION
NVPI/NVPF SERIES LIGHTING
NON-METALLIC/NON-GLASS FIXTURES L15
FEATURES-SPECIFICATIONS
L
Applications
Designed specifically for corrosive &
wet NEMA 4X and hazardous dust
environments.
Typical applications include food pro-
cessing, sewage treatment plants, off-
shore and dockside installations and
agricultural.
Features
NVP Series non-metallic light fixtures
comine an outstanding balance of
strength, stiffness, toughness and
electrical properties
Polycarbonate lens
Energy and labor saving fluorescent
or incandescent models
Molded from 30% glass-filled ther-
moset polyester for high strength
Resists corrosive effects of most
chemicals, hydrocarbons and sol-
vents
Designed for indoor and outdoor
globe down applications
All assemblies are unit packed with
required components (not assembled)
• Fluorescent unit pack models (only)
include the lamp
Fluorescent models use “world volt-
age” ballasts for 120VAC through
277VAC 50/60Hz applications
For M20 ceiling units change “X” in
part # to “M”. For wall units change
“B” to “W”. M20 Pendant not available
Pendant Fluorescent Wall Mount Fluorescent
Class II, Div. 2, Groups F,G
NEMA 3,4,4X
NVPIG75 1
NVPFG13
NVPFG18
NVPFG26
NV2AG
NV2XG
NV2BG
NV2GG
VPLCG100
VPLCG100R
VPLCG100G
Incandescent Body with E26 socket; 75W Max1
13W Fluor Body & 120 - 277VAC 50/60Hz Ballast (less lamp)
18W Fluor Body & 120 - 277VAC 50/60Hz Ballast (less lamp)
26W Fluor Body & 120 - 277VAC 50/60Hz Ballast (less lamp)
3/4" Pendant splice box
3/4" Ceiling splice box
Elbow (used between NV2XG and Fixture Body)
Guard
Clear Poly Globe
Red Poly Globe
Green Poly Globe
COMPONENTS**
Ceiling Incandescent
CATALOG NUMBER DESCRIPTION
Photometrics “similar” to those shown
on L4-L5.
See dimensions on L4
Pendant 3/4" Clear Polycarbonate Globe & Guard*
75A Incan.1
13 W Fluor.
18 W Fluor.
26 W Fluor.
NVPIG75AG
NVPFG13AG
NVPFG18AG
NVPFG26AG
Ceiling 3/4" Clear Polycarbonate Globe & Guard*
75A Incan.1
13 W Fluor.
18 W Fluor.
26 W Fluor.
NVPIG75XG
NVPFG13XG
NVPFG18XG
NVPFG26XG
Wall 3/4" Clear Polycarbonate Globe & Guard*
75A Incan.1
13 W Fluor.
18 W Fluor.
26 W Fluor.
NVPIG75BG
NVPFG13BG
NVPFG18BG
NVPFG26BG
to the following standards:
UL 1598 Standard for luminaires
UL 844 Standard for lighting fixtures for
hazardous locations
CSA C22.2 no. 137-M1981 electric lumi-
naires for use in hazardous locations
Enclosed and gasketed
NEMA 3, 4X
1Incandescent models w/medium base socket
marked for 75W 277V Max or self-ballasted
CFLs to 26W max, lamps F.O.B.
APPLICATION DATA1
75A 1F, G —— —
13 Fluor F, G -20°C -4°F .144 .067
18 Fluor F, G -20°C -4°F .158 .073
26 Fluor F, G -20°C -4°F .220 .097
CLASS II
DIV.2
CLEAR OR
COLOR
MIN. START
C° F°
WATTAGE
& TYPE
CURRENT
FLUOR. VAC
120V 277V
* Reflectors shown on L3 are not recommended - globe taper prevents guard from holding reflector securely.
** For 13-26W Quad Pin Lamps and Replacement Ballasts see page L3.
Polycarbonate Globe Options for ASSEMBLIES: Red or Green
For RED polycarbonate add -R e.g. NVPIG75AG-R
For GREEN polycarbonate add -G e.g. NVPIG75AG-G
Self-ballasted
CFLs for 26W 1
NEW!
NON-GLASS
Certified* - File LR11713
E/H SERIES LIGHTING
INCANDESCENT FIXTURES
L16
E INCANDESCENT
Applications
For hazardous locations including where
Group A or Group B gases are present,
indoors or outdoors.
General, local or supplementary lighting
in areas where Group A or Group B
gases are manufactured, used or han-
dled.
Features
Cast of corrosion resistant aluminum
alloy with electrostatically applied
epoxy/polyester finish
For 200 watt or 300 watt PS-30 medi-
um base lamps. Fixture for
lamp base-up mounting only
Omit “G” in catalog number to omit
guard
CATALOG NUMBER DESCRIPTION
EPG-2-200 Pendant 3/4" hub
EXG-2-200 Ceiling 3/4" hub
EBG-2-200 Bracket 3/4" hub
E INCANDESCENT FIXTURE
CATALOG NUMBER DESCRIPTION
HG-200 Guard
EGSA-200 Globe w/ support assembly
HRME* Replacement socket
ERSD30 Dome reflector
ERA30 Angle reflector
E ACCESSORIES
EXG-2-200
Note: For 200 watt or 300 watt PS-30 lamps.
Fixture for lamp base-up mounting only.
* Also fits discontinued H series
medium base fixtures
EPG-2-200 EBG-2-200 HG-200
200
300
90
150
T4
T3C
A, B, C, D
A, B, C, D
T3C
T3A
EFG
E, F
YES
NO
40
40
E APPLICATION DATA
LAMP
WATTS
CLASS III
SUITABILITY
SUPPLY
WIRE °C
RATED
AMBIENT °C
CLA S S I, DIV. 1 & 2
T-CODE GROUPS
CLASS II, DIV. 1 & 2
T-CODE GROUPS
Class I, Div. 1 & 2, Groups A,B,C,D
Class I, Zones 1 & 2, Groups llC,llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Groups A,B Rated
HP-2 HB-2HX-2
HRD-400
HGSA-500F HRMO
EZG1G
HP-2
HX-2
HB-2
HGSA-500F
EZG1G
HRMO
HRD-400
AVAILABLE REPLACEMENT PARTS
3/4" Pendant Mount
3/4" Ceiling Mount
3/4" Wall Mount
Globe with Support Assembly
Guard
Replacement Mogul Socket
Deep Reflector 21-1/8" dia.
E INCANDESCENT
H INCANDESCENT
CATALOG NUMBER DESCR IPTION
SERIES DISCONTINUEDSERIES DISCONTINUED
500W MOGUL BASE
Listed - File E12976
Certified - File LR11713
L17
FEATURES-SPECIFICATIONS
MBL SERIES LIGHTING
C O M PA C T L E D 2 2 & 4 5 W AT T
L
Class I, Div. 2, Groups A,B,C,D
Class l, Zone 2, Groups llC,llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
Marine
NEMA 3, 4X
Applications
CERTILITE®MBL LED fixtures are
designed for installations where mois-
ture, dirt, dust, corrosion and vibration
may be present, or NEMA 3 and 4X
areas where wind, water, snow or high
ambients can be expected. They can
be used in locations made hazardous
by the presence of flammable vapors
or gases or combustible dusts as
defined by the NEC.
Typical applications include manufac-
turing plants, and certain chemical and
petrochemical processing facilities,
sewage treatment plants, off-shore and
dockside installations, garages and
storage facilities.
Compliances
UL-8750 for LED lighting
UL Marine type lighting fixtures (HID
models) UL-844 Standard for lighting
fixtures for hazardous locations,
Class I, Division 2; Class II, Divisions
1 and 2; Class III
CSA C22.2 no. 137-M1981 electric
luminaries for use in hazardous loca-
tions
Enclosed and gasketed
NEMA 3, 4X
Materials
Ballast tank, splice box and guards
(MBAG, VMAG) corrosion resistant
copper-free aluminum alloy
Baked powder epoxy/polyester finish,
electrostatically applied for complete,
uniform corrosion protection
All external hardware - stainless steel
Reflectors - Polyester reinforced
fiberglass
LED Luminaire Features and Standards
Compact in Size with Traditional Industrial
Appearance and Suitability
Wide variety of optics including globes,
globes with reflectors, all-glass refractors,
and spin-top refractors
Optional Mounting arrangements including
Pendant, Wall, Ceiling, and Stanchion
MBL LED Housings can be retrofitted to
existing MB splice boxes; upgrade from
Fluorescent or HID
Energy Savings - less than 50 Watts of
Power; 25 Watts for MBL2230
Long Life - 50,000 - 60,000 maintenance
free hours to 70% initial lumens
Crisp White Light for Excellent Color Render-
ing - Chromaticity 5000°K (CCT); 70 CRI
Ambient suitability -40°C to 40°C (to
55°C for MBL2230)
Instant on - including after power interruption
World Voltage” 120-277VAC 50/60Hz
Solder-LESS LED Board Connections –
Vibration Resistant
Dual Drivers - Redundant Systems (built-in
backup), or for additional energy savings
half of MBL4530 can be turned off
LM80-08* Measurement of lumen mainte-
nance for LED light sources
LM79-08* Certified "Absolute" Photometry,
including Chromaticity Color for Solid
State Lighting
L70 Values - Industry Nomenclature for
Hours of use to 70% of Initial Lumens
Catalog Number Logic
Housing Series
LED Wattage
22 - 22 Watt
45 - 45 Watt
Guard
N— No Guard
G— Guard
MBL 45 30 A 2 R5 G
Mounting Style
A— Pendant
X— Ceiling
B— Wall
D— Stanchion 25o
Entry
2— 3/4" NPT (A, X, B)
3— 1" NPT (A, X, B)
4— 1-1/4" NPT (D only)
5— 1-1/2" NPT (D only)
8— M20 4 hub (X only)
LED
* LM-xx are Illumination Engineering Society Standards designed to promote uniformity in testing procedures
among test labs and manufacturers. For more information go to www.ies.org
Voltage
30 - 120-277VAC
Options
CP - Component Pack (housing, mount, optic, guard if
selected)
AN - Assembled Fixture (components as selected)
1Teflon® is a registered trademark of DuPont, Inc.
Optic
GL —Globe
R1 —Type 1 Glass Refractor
R5 —Type 5 Glass Refractor
S8 — 8" Spin-top Type V Refractor
S5 12" Spin-top V Refractor
FG —Silicone Coated Globe
T1 Teflo1coated Type 1
Glass Refractor
T5 Teflon® coated Type V
Glass Refractor
T8 8" Teflon® Spin-top V Refractor
TV —12" Teflon® Spin-top V Refractor
LED
TECHNOLOGY
Certified - File LR11713
MBL SERIES LIGHTING
C O M PA C T L E D 2 2 & 4 5 W AT T
L18
ORDERING INFORMATION
1Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. MBL2230A2GLN
2Catalog numbers shown are with 3/4" conduit openings; change “2” to “3” for 1" e.g. MBL2230A3GLG
3120VAC through 277VAC 50/60Hz
4Catalog numbers shown are with 1-1/4" conduit openings; change “4” to “5” for 1-1/2" e.g. MBL2230D5GLG
MBL SERIES PENDANT WITH OPTIC AND GUARD1
WATTS HUB SIZE2VOLTAGE3GLOBE & GUARD TYPE I GLASS TYPE V GLASS 8" SPIN-TOP TYPE V 12" SPIN-TOP TYPE V
REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD
22 3/4" 120-277VAC MBL2230A2GLG MBL2230A2R1G MBL2230A2R5G MBL2230A2S8G MBL2230A2S5G
45 3/4" 120-277VAC MBL4530A2GLG MBL4530A2R1G MBL4530A2R5G MBL4530A2S8G MBL4530A2S5G
MBL SERIES CEILING WITH OPTIC AND GUARD1
WATTS HUB SIZE2VOLTAGE3GLOBE & GUARD TYPE I GLASS TYPE V GLASS 8" SPIN-TOP TYPE V 12" SPIN-TOP TYPE V
REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD
22 3/4" 120-277VAC MBL2230X2GLG MBL2230X2R1G MBL2230X2R5G MBL2230X2S8G MBL2230X2S5G
45 3/4" 120-277VAC MBL4530X2GLG MBL4530X2R1G MBL4530X2R5G MBL4530X2S8G MBL4530X2S5G
MBL SERIES WALL WITH OPTIC AND GUARD1
WATTS HUB SIZE2VOLTAGE3GLOBE & GUARD TYPE I GLASS TYPE V GLASS 8" SPIN-TOP TYPE V 12" SPIN-TOP TYPE V
REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD
22 3/4" 120-277VAC MBL2230B2GLG MBL2230B2R1G MBL2230B2R5G MBL2230B2S8G MBL2230B2S5G
45 3/4" 120-277VAC MBL4530B2GLG MBL4530B2R1G MBL4530B2R5G MBL4530B2S8G MBL4530B2S5G
MBL SERIES 25oSTANCHION WITH OPTIC AND GUARD1
WATTS HUB SIZE4VOLTAGE5GLOBE & GUARD TYPE I GLASS TYPE V GLASS 8" SPIN-TOP TYPE V 12" SPIN-TOP TYPE V
REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD
22 1-1/4" 120-277VAC MBL2230D4GLG MBL2230D4R1G MBL2230D4R5G MBL2230D4S8G MBL2230D4S5G
45 1-1/4" 120-277VAC MBL4530D4GLG MBL4530D4R1G MBL4530D4R5G MBL4530D4S8G MBL4530D4S5G
CEILING
PENDANT WALL
STANCHION
MBL SERIES LIGHTING
COMPONENT PARTS / ELECTRICAL & TEMPERATURE DATA L19
L
Wall
Pendant Ceiling Stanchion
MBG
* MBX-8 furnished with 3 non-metallic plugs
HUB SIZE
3/4"
1"
M20
1-1/4"
1-1/2"
CATALOG NUMBER
PENDANT CEILING WALL STANCHION
MBA-2 MBX-2 MBB-2
MBA-3 MBX-3 MBB-3
MBX-8* ——
—— — MBD-4
—— — MBD-5
MB MOUNTING BRACKETS
VMRWG85
VZRG1550 VZRG2550
VMAG17
VMR175
VMR171
VMRWGS5
VMPA-17
VMPSD-17 VMFSPC1
O
P
T
I
C
S
A
C
C
E
S
S
O
R
I
E
S
MBAG
DESCRIPTION OPTIC LOGIC GUARD
MBL LED OPTICS AND ACCESSORIES
Globe (glass)
Refractor (all glass) Type I
Refractor (all glass) Type V
Refractor (spin top) 8" Type V
Refractor (spin top) 12" Type V
Globe (Silicone coated)
Refractor Teflon®1coated (all glass) Type I
Refractor Teflon®coated (all glass) Type V
Refractor (spin top) 8" Type V
Refractor (spin top) 12" Type V
Reflector for MBG Globe - DOME 2
Reflector for MBG Globe - ANGLE 2
120VAC Photocell with FS Style Cover
208-277VAC Photocell with FS Style Cover
3-sided EXIT Accessory (use without guard)
MBG (GL)
VMR171 (R1)
VMR175 (R5)
VZRG1550 (S8)
VZRG2550 (S5)
MBGT (FG)
VMR171T (T1)
VMR175T (T5)
VZRG1550T (T8)
VZRG2550T (TV)
VMPSD-17
VMPA-17
VMFSPC1
VMFSPC2
VEXA100B
MBAG
VMAG17
VMAG17
VMRWG8
VMRWGS
MBAG
VMAG17
VMAG17
VMRWG8
VMRWGS
NA
NA
NA
NA
NA
1Teflon is a registered trademark of DuPont, Inc.
2Reflectors for use with MBG/MBAG only; VMG17 globe with VMAG17 guard will fit without reflector.
CAT. NO. VOLTAGE 50/60HZ WATTAGE AMPS 120/277 CIL3WEIGHT
MBL LED HOUSINGS WITH DRIVERS AND LEDS - ELECTRICAL RATINGS
MBL2230 120-277VAC 25.8 .215/.093 1980 8 LBS
MBL4530 120-277VAC 48.4 .416/.180 3960 15.5 LBS
CAT. NO. AMBIENT C1D2 C2D1 L70 SUPPLY WIRE
THERMAL PERFORMANCE DATA (ANY OPTIC)
MBL2230 40OC T4A T4 (EFG) 60,000 HRS 75OC
MBL2230 55OC T4 T4(EFG) 50,000 HRS 90OC
MBL4530 40OC T4A T4(EFG) 55,000 HRS 90OC
3CIL = Calculated Initial Lumens of LED component based on mfg. data and driver current INSIDE the optic. This value is provided as a reference only for com-
parison to traditional light sources such as incandescent, HID, or fluorescent which use initial values in “relative” photometry. KILLARK LED luminaires are tested
using the Absolute photometry method (LM79-08), which calculates delivered lumens only. KILLARK’s LED luminaires provide very bright white 5000OK (CCT)
color and can appear brighter than traditional light sources with higher lumen values under both photopic and scotopic conditions.
4Driver THD < 20%, Powerfactor 99% @ 120V; Line Regulation 2%; Load regulation 5%; Protected against Over-voltage and Over-current.
5VMRWG8 Plated Steel, VMRWGS 316 Stainless Steel.
VEXA100B
MBL SERIES LIGHTING
DIMENSIONS / PHOTOMETRIC DATA
L20
MBA Pendant
1.29
9.90
4.63 4.56
9.63 10.95
8.38
2.04 1.69
2.90
10.60
10.84
9.82
4.88
2.90
9.59
10.22
9.90
.89
1.00
2.90
11.15
9.82
4.63
8.16 DIA.
1.00
.94
.94
45o
1.31
13.32
9.31
1.05
.94
MBX Ceiling
MBL Pendant, Globe, Guard
MBL & MBG Globe Only
MBL & 8" Type V Spin-top
MBB Wall Mount
LED 45 Watt Globe Only1
122W model values approx. 50% of 45W
MBD Stanchion
MBL Pendant, Refractor, Guard
MBL & VMR Refractor
MBL & 12" Type V Spin-top
2.90
13.13
4.63
9.32
10.68
2.90
9.82
4.63
9.90
4.56
2.50
13.28
7.32
4.63
3.04
4.96
11.69
2.90
11.85
12.19 DIA.
5.31 DIA.
1.00
1.00
2.25 25o
9.9
MBL SERIES LIGHTING
PHOTOMETRIC DATA L21
L
LED 45Watt Globe & Dome Reflector1LED 45Watt Glass Type V Refractor1LED 45Watt 8" Spin-top Type V Refractor1
122W model values approx. 50% of 45W
MB SERIES LIGHTING
FLUORESCENT BI-PIN/MEDIUM BASE HID
L22
FEATURES-SPECIFICATIONS
Listed - Files E10514 and
E91793 (Marine)
Certified - File LR11713
Class I, Div. 2, Groups A,B,C,D*
Class l, Zone 2, Groups llC,llB,llA
Class II, Div. 1 & 2, Groups E,F,G*
Class III
Suitable for wet locations
Marine
NEMA 3, 4X
Pendant Ceiling Wall Stanchion
Applications
CERTILITE®MB fixtures are designed
for installations where moisture, dirt,
dust, corrosion and vibration may be
present, or NEMA 3 and 4X areas
where wind, water, snow or high ambi-
ents can be expected. They can be
used in locations made hazardous by
the presence of flammable vapors or
gases or combustible dusts as defined
by the NEC.
Typical applications include manufac-
turing plants, and certain chemical and
petrochemical processing facilities,
sewage treatment plants, off-shore and
dockside installations, garages and
storage facilities.
Compliances
UL-1572 Standard for HID lighting
fixtures
UL-1570 Standard for Fluorescent
fixtures
UL Marine type lighting fixtures (HID
models) UL-844 Standard for lighting
fixtures for hazardous locations,
Class I, Division 2; Class II, Divisions
1 and 2; Class III
CSA C22.2 no. 137-M1981 electric
luminaries for use in hazardous
locations
Enclosed and gasketed
NEMA 3, 4X
Features
Ballast tank and splice box —
corrosion resistant copper-free
aluminum alloy
Baked powder epoxy/polyester finish,
electrostatically applied for complete,
uniform corrosion protection
All external hardware — stainless
steel
Guard — copper-free aluminum alloy
Normally shipped as components for
quick delivery
Refractor guard — steel with corro-
sion resistant finish
Reflector — lightweight, corrosion
resistant fiberglass reinforced
polyester
Fluorescent models furnished with
lamps. Energy efficient instant on
white light (2700K). 10,000 hour
lamp life
HID lamp holders are E26 medium
base
Catalog Number Logic
Series Constant
Lamp Type
FFluorescent
L—High Pressure Sodium
H—Metal Halide
K—MV Mercury Vapor
Lamp Wattage
13—(1) 13 Watt PL Lamp
26—(2) 13 Watt PL Lamp
39—(3) 13 Watt PL Lamp
50—50 Watt—HPS/MH
70—70 Watt—HPS/MH
10—100 Watt—HPS/MH
15—150 Watt—HPS Voltage V
0—Quad - 120/208/240/277 Volts 60 Hz (50, 70 HPS/MH)
1—120 Volts 60 Hz (HPS/Fluorescent)
4—277 Volts 60 Hz (13, 26 Watt Fluorescent)
Optic
G—Fluted Glass Globe
GG—Globe and Guard
R5—Glass Refractor Type V
R5G—Glass Refractor & Guard
MB 0 00 0 - 000 00
Consult factory for available lamp and voltage combinations.
* See Hazardous Location Application Data on page L28 for limitations.
Mounting Style
A2—3/4" Pendant
A3—1" Pendant
X2—3/4" Ceiling
X3—1" Ceiling
B2—3/4" Wall Bracket
B3—1" Wall Bracket
D4—1-1/4" Stanchion
D5—1-1/2" Stanchion
Options
SU103—Assembled
w/Lamp
V
L
MB SERIES LIGHTING
COMPACT BI-PIN FLUORESCENT, 13-39 WATT L23
FEATURES-SPECIFICATIONS
Listed - Files E10514 and
E91793
Certified - File LR11713
Class I, Div. 2, Groups A,B,C,D*
Class l, Zone 2, Groups llC,llB,llA
Class II, Div. 1 & 2, Groups E,F,G*
Class III
Suitable for wet locations
NEMA 3, 4X
1Fixtures supplied with Bi-Pin fluorescent lamps. Replacement number MPL13.
2Catalog numbers shown are with 3/4" conduit openings (1-1/4" on stanchion mount) and include
globe and guard. See catalog logic for other possible configurations.
3Catalog numbers are shown with 120V ballasts. 1 & 2 lamp fixtures are available with 277V ballasts
Change 6th character from “1” to “4; e.g. MBF264-GGA2.
* See Hazardous Location Application Data on page L28 for limitations.
CATALOG NUMBER2
GLOBE AND GUARD REFRACTOR AND GUARD
3/4" 120 MBF131-GGA2 MBF131-R5GA2
Bi-Pin 3/4" 120 MBF261-GGA2 MBF261-R5GA2
3/4" 120 MBF391-GGA2 MBF391-R5GA2
PENDANT FLUORESCENT
LAMP LAMP/1HUB
TYPE WATTS SIZE1
CEILING
PENDANT
STANCHION
WALL
CATALOG NUMBER2
GLOBE AND GUARD REFRACTOR AND GUARD
3/4" 120 MBF131-GGX2 MBF131-R5GX2
Bi-Pin 3/4" 120 MBF261-GGX2 MBF261-R5GX2
3/4" 120 MBF391-GGX2 MBF391-R5GX2
CEILING FLUORESCENT
LAMP LAMP/1HUB
TYPE WATTS SIZE2
CATALOG NUMBER2
GLOBE AND GUARD REFRACTOR AND GUARD
3/4" 120 MBF131-GGB2 MBF131-R5GB2
Bi-Pin 3/4" 120 MBF261-GGB2 MBF261-R5GB2
3/4" 120 MBF391-GGB2 MBF391-R5GB2
WALL FLUORESCENT
LAMP LAMP/1HUB
TYPE WATTS SIZE2
CATALOG NUMBER2
GLOBE AND GUARD REFRACTOR AND GUARD
1-1/4" 120 MBF131-GGD4 MBF131-R5GD4
Bi-Pin 1-1/4" 120 MBF261-GGD4 MBF261-R5GD4
1-1/4" 120 MBF391-GGD4 MBF391-R5GD4
STANCHION FLUORESCENT
LAMP LAMP/1HUB
TYPE WATTS SIZE2
13 Watt
(1 x 13)
26 Watt
(2 x 13)
39 Watt
(3 x 13)
13 Watt
(1 x 13)
26 Watt
(2 x 13)
39 Watt
(3 x 13)
13 Watt
(1 x 13)
26 Watt
(2 x 13)
39 Watt
(3 x 13)
13 Watt
(1 x 13)
26 Watt
(2 x 13)
39 Watt
(3 x 13)
VOLTAGE
60 HZ 3
VOLTAGE
60 HZ 3
VOLTAGE
60 HZ 3
VOLTAGE
60 HZ 3
MB SERIES LIGHTING
HIGH PRESSURE SODIUM, 50-150W MEDIUM BASE HID
L24
FEATURES-SPECIFICATIONS
Listed - Files E10514 and
E91793 (Marine)
Certified - File LR11713
Class I, Div. 2, Groups A,B,C,D*
Class l, Zone 2, Groups llC,llB,llA
Class II, Div. 1 & 2, Groups E,F,G*
Class III
Suitable for wet locations
UL Marine
NEMA 3, 4X
1Catalog numbers shown are 120. Consult factory for other available voltages.
2Catalog numbers shown with 3/4" conduit openings (1-1/4" on stanchion mount) and includes globe and
guard or IES type V 8" glass refractor and guard. See catalog logic for other possible configurations.
* See Hazardous Location Application Data on page L28 for limitations.
PENDANT 50-150W HIGH PRESSURE SODIUM
LAMP LAMP HUB
TYP E WATTS/ANSI SIZE2
CEILING 50-150W HIGH PRESSURE SODIUM
LAMP LAMP HUB
TYP E WATTS/ANSI SIZE2
WALL 50-150W HIGH PRESSURE SODIUM
LAMP LAMP HUB
TYP E WATTS/ANSI SIZE2
STANCHION 50-150W HIGH PRESSURE SODIUM
LAMP LAMP HUB
TYP E WATTS/ANSI SIZE2
CEILING
STANCHION
WALL
PENDANT
VOLTAGE
60 HZ 1
VOLTAGE
60 HZ 1
VOLTAGE
60 HZ 1
VOLTAGE
60 HZ 1
CATALOG NUMBER2
GLOBE AND GUARD REFRACTOR AND GUARD
50 (S68) 3/4" 120 MBL501-GGA2 MBL501-R5GA2
HPS 70 (S62) 3/4" 120 MBL701-GGA2 MBL701-R5GA2
100 (S54) 3/4" 120 MBL101-GGA2 MBL101-R5GA2
150 (S55) 3/4" 120 MBL151-GGA2 MBL151-R5GA2
CATALOG NUMBER2
GLOBE AND GUARD REFRACTOR AND GUARD
50 (S68) 3/4" 120 MBL501-GGX2 MBL501-R5GX2
HPS 70 (S62) 3/4" 120 MBL701-GGX2 MBL701-R5GX2
100 (S54) 3/4" 120 MBL101-GGX2 MBL101-R5GX2
150 (S55) 3/4" 120 MBL151-GGX2 MBL151-R5GX2
CATALOG NUMBER2
GLOBE AND GUARD REFRACTOR AND GUARD
50 (S68) 3/4" 120 MBL501-GGB2 MBL501-R5GB2
HPS 70 (S62) 3/4 120 MBL701-GGB2 MBL701-R5GB2
100 (S54) 3/4" 120 MBL101-GGB2 MBL101-R5GB2
150 (S55) 3/4" 120 MBL151-GGB2 MBL151-R5GB2
CATALOG NUMBER2
GLOBE AND GUARD REFRACTOR AND GUARD
50 (S68) 1-1/4" 120 MBL501-GGD4 MBL501-R5GD4
HPS 70 (S62) 1-1/4" 120 MBL701-GGD4 MBL701-R5GD4
100 (S54) 3/4" 120 MBL101-GGD4 MBL101-R5GD4
150 (S55) 1-1/4" 120 MBL151-GGD4 MBL151-R5GD4
150 1-1/4" 120 MBL151-GGD4 MBL151-R5GD4
MB SERIES LIGHTING
METAL HALIDE, 50-100W MEDIUM BASE HID L25
ORDERING INFORMATION
Listed - Files E10514 and
E91793 (Marine)
Certified - File LR11713
Class I, Div. 2, Groups A,B,C,D*
Class l, Zone 2, Groups llC,llB,llA
Class II, Div. 1 & 2, Groups E,F,G*
Class III
Suitable for wet locations
UL Marine
NEMA 3, 4X
PENDANT 50-100W METAL HALIDE
CEILING 50-100W METAL HALIDE
LAMP LAMP HUB
TYP E WATTS/ANSI SIZE2
WALL 50-100W METAL HALIDE
LAMP LAMP HUB
TYP E WATTS/ANSI SIZE2
STANCHION 50-100W METAL HALIDE
CEILING
STANCHION
WALL
PENDANT
1Metal Halide MB fixtures use quad-volt ballasts.
2Catalog numbers shown with 3/4" conduit openings (1-1/4" on stanchion mount) and include globe and
guard or IES type V 8" glass refractor and guard. See catalog logic for other possible configurations.
350,70, 100 MH Ballasts include a separate ignitor and are PULSE circuits.
* See Hazardous Location Application Data on page L28 for limitations.
VOLTAGE
60 HZ 1
VOLTAGE
60 HZ 1
VOLTAGE
60 HZ 1
LAMP LAMP HUB
TYP E WATTS/ANSI SIZE2
CATALOG NUMBER2
GLOBE AND GUARD REFRACTOR AND GUARD
MH
50 (M110) 3/4" 120/208/240/277 MBH500-GGA2 MBH500-R5GA2
70 (M98) 3/4" 120/208/240/277 MBH700-GGA2 MBH700-R5GA2
100 (M90) 3/4" 120/208/240/277 MBH100-GGA2 MBH100-R5GA2
VOLTAGE
60 HZ 1
LAMP LAMP HUB
TYP E WATTS/ANSI SIZE2
CATALOG NUMBER2
GLOBE AND GUARD REFRACTOR AND GUARD
MH
50 (M110) 1-1/4" 120/208/240/277 MBH500-GGD4 MBH500-R5GD4
70 (M98) 1-1/4" 120/208/240/277 MBH700-GGD4 MBH700-R5GD4
100 (M90) 1-1/4" 120/208/240/277 MBH100-GGD4 MBH100-R5GD4
CATALOG NUMBER2
GLOBE AND GUARD REFRACTOR AND GUARD
MH
50 (M110) 3/4" 120/208/240/277 MBH500-GGB2 MBH500-R5GB2
70 (M98) 3/4" 120/208/240/277 MBH700-GGB2 MBH700-R5GB2
100 (M90) 3/4" 120/208/240/277 MBH100-GGB2 MBH100-R5GB2
CATALOG NUMBER2
GLOBE AND GUARD REFRACTOR AND GUARD
MH
50 (M110) 3/4" 120/208/240/277 MBH500-GGX2 MBH500-R5GX2
70 (M98) 3/4" 120/208/240/277 MBH700-GGX2 MBH700-R5GX2
100 (M90) 3/4" 120/208/240/277 MBH100-GGX2 MBH100-R5GX2
L
3
3
3
3
MB SERIES LIGHTING
COMPONENT PARTS/BALLAST DATA
L26
Wall
Pendant Ceiling Stanchion
4Catalog numbers shown are 120 volt (except
Metal Halide). Consult catalog number logic
on page L22 and change sixth character to
indicate other available voltages.
* MBX-8 furnished with 3 non-metallic plugs
LAMP TYPE OPEN INPUT MINIMUM
STARTING OPERATING CIRCUIT WATTS START
LAMP WATTS VOLTS - VAC AMPS AMPS AMPS MAX TEMPERATURE
FL113 120/277 .30/.3 16 0°F -18°C
50 120 .55 .90 60 -40°F -40°C
HPS 70 120 .75 1.30 82 -40°F -40°C
100 120 1.05 1.80 115 -40°F -40°C
150 120 1.50 2.35 170 -40°F -40°C
50 120/208 .6/.35/.3/.25 1.6/.67/.57/.5 67 -20°F -30°C
240/277
MH 70 120/208 .85/.5/.43/.37 1.7/1.04/.87/.78 95 -20°F -30°C
240/277
100 120/208 1.15/.66/.58/.5 2.3/1.4/1.15/1.0 129 -20°F -30°C
240/277
MB BALLAST DATA
1Per lamp, max available lamps @ 120 volt is .3; max @ 277 volt is .2.
2Ballasts are High Power Factor 90%+.
3Lamp watts within ANSI Trapezoid limitations.
HUB SIZE
3/4"
1"
M20
1-1/4"
1-1/2"
CATALOG NUMBER
PENDANT CEILING WALL STANCHION
MBA-2 MBX-2 MBB-2
MBA-3 MBX-3 MBB-3
MBX-8* ——
—— MBD-4
—— — MBD-5
120
120
120
120
120
120
120
120/208/240/277
120/208/240/277
120/208/240/277
MB BALLAST TANK4
CATALOG
NUMBER
MBF131
MBF261
MBF391
MBL501
MBL701
MBL101
MBL151
MBH500
MBH700
MBH100
LAMP
TYPE
FL
HPS
MH
LAMP
WATTAGE
13
26
39
50
70
100
150
50
70
100
MB MOUNTING BRACKETS
ENY-2SET
EMRS
EBRS
.39/.35
.75
.85
1.50
2.20
.87/.51/.47/.39
.8/.5/.43/.39
1.2/.8/.65/.6
BALLAST
CIRCUIT REGULATIONS
±5% Line voltage3
±5% Line voltage3
±5% Line voltage3
±5% Line voltage3
±5% Line voltage3
±12% Lamp watts3
±5% Line voltage3
±12% Lamp watts3
±5% Line voltage3
±12% Lamp watts3
EMRS
EBRS
MPL13
ENY-2SET
ENY-3SET
MB medium base replacement socket (E26)
MB Bi-Pin base replacement socket
Replacement lamp for MBF and EBF series
3/4" ENY seal with set screw for sealed (Ex nR) pendant installations
1" ENY seal with set screw for sealed (Ex nR) pendant installations
MB ACCESSORIES
CATALOG NUMBER DESCRIPTION
VOLTAGE
60 HZ
NPF
HX-HPF2
HX-HPF2
HX-HPF2
HX-HPF2
HX-HPF2
HX-HPF2
HX-HPF2
MB SERIES LIGHTING
ACCESSORIES/DIMENSIONS L27
ORDERING INFORMATION
L
MBG
Globe
VZRG1550
Refractor
MBAG VMRWG8 VMPSD-17 VMPA-17
ReflectorsGuards
Dimensions
MBG
VZRG1550
MBAG
VMRWG8
VMPSD-17
VMPA-17
Heat and impact resistant globe
(I.E.S. Type V) closed bottom 8" glass refractor
Globe guard - Epoxy/polyester painted aluminum
Refractor guard - plated steel
Standard dome reflector (fiberglass reinforced polyester)
Angle reflector (fiberglass reinforced polyester)
MB ACCESSORIES
CATALOG NUMBER DESCRIPTION
CLASS I, DIV. 2, GROUPS A, B, C, D1CLASS II, DIV. 1 & 2, GROUPS E, F, G35
LAMP RATED LAMP TEMPERATURES MAXIMUM SURFACE TEMPERATURES CLASS III, DIV. 1 & 23
AMBIENT
°C WITHOUT4WITH2WITH WITHOUT4WITH2WITH WITHOUT4WITH2WITH
TYPE WATTAGE REFLECTOR REFLECTOR REFRACTOR REFLECTOR REFLECTOR REFRACTOR REFLECTOR REFLECTOR REFRACTOR
50 40 215°C(T2D) 215°C(T2D) 215°C(T2D) 120°C(T4A) 135°C(T4) 120°C(T4A) YES YES YES 75
50 55 230°C(T2C) 230°C(T2C) 230°C(T2C) 135°C(T4) 160°C(T3C) 135°C(T4) YES YES YES 90
50 65 230°C(T2C) 230°C(T2C) 230°C(T2C) 160°C(T3C) 160°C(T3C) 160°C(T3C) YES YES YES 90
HPS 70 40 260°C(T2B) 260°C(T2B) 230°C(T2C) 120°C(T4A) 135°C(T4) 120°C(T4A) YES YES YES 75
100 40 280°C(T2A) 280°C(T2A) 280°C(T2A) 160°C(T3C) 160°C(T3C) 160°C(T3C) YES YES YES 90
150 40 325°C(T1) 325°C(T1) 325°C(T1) ——160°C(T3C) NO NO YES 110
150 40 325°C(T1) 325°C(T1) 325°C(T1) 180°C(T3A) 200°C(T3) NO NO NO 110
50 40 230°C(T2C) 230°C(T2C) 230°C(T2C) 160°C(T3C) 160°C(T3C) 160°C(T3C) YES YES YES 90
MH 70 40 230°C(T2C) 230°C(T2C) 230°C(T2C) 160°C(T3C) 160°C(T3C) 160°C(T3C) YES YES YES 90
100 40 280°C(T2A) 280°C(T2A) 280°C(T2A) 160°C(T3C) 160°C(T3C) 160°C(T3C) YES YES YES 85
MB SERIES LIGHTING
A P P L I C AT I O N D ATA
L28
1Verify temperatures for suitability for intended use.
2Includes both standard dome and angle reflectors.
3Guard required for Class II, Division 1 and Class III applications.
4Based on luminaire with globe and guard only.
5150 watt HPS—Groups E, F only with or without reflector and Groups E, F and G with refractor.
LAMP
TYPE
PL
RATED
AMBIENT°C
40
40
25
CLASS I, DIVISION 2
GROUPS A, B, C, D1
LAMP TEMP, W/GLOBE,
GLOBE & REFLECTOR2
OR 8" GLASS REFRACTOR
CLASS II, DIVISION 1 & 21
MAXIMUM SURFACE
TEMPERATURE W/GLOBE,
GUARD3& REFLECTOR2
OR 8" GLASS REFRACTOR4
CLASS III, DIV. 1 & 21
W/GLOBE, W/GUARD3&
REFLECTOR2
OR 8" GLASS REFRACTOR
UL/CSA
TEMP I.D.
(T3B) 165°C
(T3B) 165°C
(T3A) 180°C
GROUP
E,F&G
E,F&G
E,F&G
UL/CSA
YES
YES
YES
UL/CSA
TEMP I.D.
(T4) 135°C
(T4) 135°C
(T4) 135°C
LAMPS/
WATTS
13
26 (2x13)
39 (3x13)
MBF HAZARDOUS LOCATION DATA
1Verify temperatures for suitability for intended use.
2Includes both standard dome and angle reflectors.
3Guard required for Class II, Division 1 and Class III, Division 1 applications.
4Note: 8 inch glass refractor not CSA certified for Class II, Division 1 and Class III, Divisions 1 installations.
SUPPLY WIRE
SUITABLE
FOR °C
90
90
90
SUPPLY
WIRE
SUITABLE
FOR °C
MB HAZARDOUS LOCATION DATA
MB SERIES LIGHTING
PHOTOMETRIC DATA L29
CANDLEPOWER100 WATT
B-17 Clear Lamp
(9500 Lumens)
For CP of a 70 Watt
Luminaire multiply by .663;
For a 50 Watt Luminaire
multiply by .421
CANDLEPOWER150 WATT
B-17 Clear Lamp
(16000 Lumens)
CANDLEPOWER100 WATT
B-17 Clear Lamp
(9500 Lumens)
For CP of a 70 Watt
Luminaire multiply by .663;
For a 50 Watt Luminaire
multiply by .421
HIGH PRESSURE SODIUM
With Globe Only
50 – 100 Watt Medium Base
HIGH PRESSURE SODIUM
With Globe Only
150 Watt Medium Base
HIGH PRESSURE SODIUM
With Globe and Dome Reflector
50 – 100 Watt Medium Base
Test No. HP-03126 Test No. HP-03128 Test No. HP-03125
L
CANDLEPOWER–150 WATT
B-17 Clear Lamp
(16000 Lumens)
CANDLEPOWER–100 WATT
B-17 Clear Lamp
(9500 Lumens)
For CP of a 70 watt luminaire
multiply by .663;
For a 50 watt luminaire
multiply by .421
CANDLEPOWER150 WATT
B-17 Clear Lamp
(16000 Lumens)
HIGH PRESSURE SODIUM
With Globe and Dome Reflector
150 Watt Medium Base
HIGH PRESSURE SODIUM
With Type V 8" Refractor
50 – 100 Watt Medium Base
HIGH PRESSURE SODIUM
With Type V 8" Refractor
150 Watt Medium Base
Test No. HP-03130 Test No. HP-03127 Test No. HP-03129
MB SERIES LIGHTING
PHOTOMETRIC DATA
L30
HIGH PRESSURE SODIUM
With Globe and 30° Angle Reflector
50 – 100 Watt Medium Base
HIGH PRESSURE SODIUM
With Globe and 30° Angle Reflector
150 Watt Medium Base
METAL HALIDE
With Globe Only
50 – 100 Watt Medium Base
Test No. HP-03124 Test No. HP-03131 Test No. HP-03138
See above for other values
CANDLEPOWER100
B-17 Clear Lamp
(9500 Lumens)
For CP of a 70 Watt Luminaire
multiply by .663;
For a 50 Watt Luminaire
multiply by .421
WATT CANDLEPOWER–150 WATT
B-17 Clear Lamp
(16000 Lumens)
CANDLEPOWER100 WATT MV
B-17 Clear Lamp
(4400 Lumens)
For a 50 Watt MH Luminaire
multiply by .77;
For a 70 Watt MH Luminaire
multiply by 1.36
For a 100 Watt MH Luminaire
multiply by 1.93
MB SERIES LIGHTING
PHOTOMETRIC DATA L31
L
MB SERIES LIGHTING
PHOTOMETRIC DATA
L32
CANDLEPOWER–100 WATT MV
B-17 Clear Lamp
For a 50 Watt MH Luminaire multiply by .77;
For a 70 Watt MH Luminaire
multiply by 1.36
For a 100 Watt MH Luminaire
multiply by 1.93
METAL HALIDE
With Globe and Dome Reflector
50 – 100 Watt Medium Base
METAL HALIDE
With Type V 8" Refractor
50 – 100 Watt Medium Base
METAL HALIDE
With Globe and 30° Angle Reflector
50 – 100 Watt Medium Base
Test No. HP-03139 Test No. HP-03141 Test No. HP-03140
See above for other values See above for other values See above for other values
CANDLEPOWER100 WATT MV
B-17 Clear Lamp
(4400 Lumens)
For a 50 Watt MH Luminaire multiply by .77;
For a 70 Watt MH Luminaire
multiply by 1.36
For a 100 Watt MH Luminaire
multiply by 1.93
CANDLEPOWER100 WATT MV
B-17 Clear Lamp
(4400 Lumens)
For a 50 Watt MH Luminaire multiply by .77;
For a 70 Watt MH Luminaire
multiply by 1.36
For a 100 Watt MH
Luminaire multiply
by 1.93
MBF SERIES LIGHTING
PHOTOMETRIC DATA L33
FLUORESCENT
With Globe Only—13 Watt
CANDLEPOWER
—13 WATT
(900 Lumens
One Lamp)
FLUORESCENT
With Globe Only—26 Watt
CANDLEPOWER
—26 WATT
(1800 Lumens
Two Lamps)
FLUORESCENT
With Globe Only—39 Watt
CANDLEPOWER
—39 WATT
(2700 Lumens
Three Lamps)
Test No. 5659.1 Test No. 5658.0 Test No. 5657.0
Efficiency 92.4% Efficiency 76.7% Efficiency 70.6%
L
MBF SERIES LIGHTING
PHOTOMETRIC DATA
L34
Test No. 5689.0 Test No. 5692.0 Test No. 5691.0
FLUORESCENT
With Globe and Dome
Reflector—26 Watt
CANDLEPOWER
—26 WATT
(1800 Lumens
Two Lamp)
For CP of a 13 Watt
Luminaire Multiply by .50
FLUORESCENT
With Globe and Dome
Reflector—39 Watt
CANDLEPOWER
—39 WATT
(2700 Lumens
Three Lamps)
FLUORESCENT
With Type V “8”
Refractor—26 Watt
CANDLEPOWER
—26 WATT
(1800 Lumens
Two Lamps)
For CP of a 13 Watt
Luminaire multiply by .50
Efficiency 62.8% Efficiency 60.9% Efficiency 58.4%
MBF SERIES LIGHTING
PHOTOMETRIC DATA L35
CANDLEPOWER
–26 WATT
(1800 Lumens
Two Lamps)
For CP of a 13 Watt
Luminaire multiply by .50
Test No. 5694.0 Test No. 5690.0 Test No. 5693.0
FLUORESCENT
With Globe and 30° Angle Reflector
—26 Watt
FLUORESCENT
With Globe and 30° Angle Reflector
—39 Watt
CANDLEPOWER
–39 WATT
(2700 Lumens
Three Lamps)
Efficiency 54.7%
Efficiency 57.2% Efficiency 58.3%
FLUORESCENT
With Type V “8” Refractor39 Watt
CANDLEPOWER
–39 WATT
(2700 Lumens
Three Lamps)
L
VM1L SERIES LIGHTING
REDUCED PROFILE LED 45 WATT
L36
FEATURES-SPECIFICATIONS
Class I, Div. 2, Groups A,B,C,D
Class l, Zone 2, Groups llC,llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
Marine
NEMA 3, 4X
Applications
CERTILITE®V VM1L LED fixtures are
designed for installations where mois-
ture, dirt, dust, corrosion and vibration
may be present, or NEMA 3 and 4X
areas where wind, water, snow or high
ambients can be expected. They can
be used in locations made hazardous
by the presence of flammable vapors
or gases or combustible dusts as
defined by the NEC.
Typical applications include manufac-
turing plants, and certain chemical and
petrochemical processing facilities,
sewage treatment plants, off-shore and
dockside installations, garages and
storage facilities.
Compliances
UL-8750 for LED lighting
UL Marine type lighting fixtures (HID
models) UL-844 Standard for lighting
fixtures for hazardous locations,
Class I, Division 2; Class II, Divisions
1 and 2; Class III
CSA C22.2 no. 137-M1981 electric lumi-
naries for use in hazardous locations
Enclosed and gasketed
NEMA 3, 4X
Materials
Ballast tank, splice box and cast
guards corrosion resistant copper-free
aluminum alloy
Baked powder epoxy/polyester finish,
electrostatically applied for complete,
uniform corrosion protection
All external hardware - stainless steel
Reflectors - Polyester reinforced
fiberglass
LED Luminaire Features and Standards
Reduced profile with Traditional
Industrial Appearance and Suitability
Wide variety of optics including
globes, globes with reflectors, all-glass
refractors, and spin-top refractors
Swing-Barrel Nut patented tank
mounting system
Optional Mounting arrangements
including Pendant, Wall, Ceiling,
Stanchion and others
VM1L LED Housings can be retrofitted
to existing VM splice boxes; upgrade
from HID sources
Energy Savings - less than 50 Watts
of Power
Long Life - 50,000 - 55,000 mainte-
nance free hours to 70% initial lumens
Crisp White Light for Excellent Color Render-
ing - Chromaticity 5000°K (CCT); 70 CRI
Ambient suitability -40°C to 55°C
Instant on - including after power interruption
World Voltage” 120-277VAC 50/60Hz
Solder-LESS LED Board Connections –
Vibration Resistant
Dual Drivers - Redundant Systems (built-in
backup), or for additional energy savings
half of VM1L4530 can be turned off
LM80-08* Measurement of lumen
maintenance for LED light sources
LM79-08* Certified “Absolute” Photometry,
including Chromaticity Color for Solid
State Lighting
L70 Values - Industry Nomenclature for
Hours of use to 70% of Initial Lumens
®
LED
* LM-xx are Illumination Engineering Society Standards designed to promote uniformity in testing
procedures among test labs and manufacturers. For more information go to www.ies.org
Swing-Barrel Nut
123
Hang
Fixture Swing into Place Tighten
Sealed Optic Zone 2
AEx nAR Restricted
Breathing (suffix NR)
No External Seals. Lower T-codes. Suitable for
Class I Div. 2 Classified areas per the NEC®
Earthquake Tab - Built-in
attachment point for safety
cables.
Available as Field or Factory Installed to save
energy when light not required.
Photo controls - Class I
Div. 2 / N4X areas
For easy fixture relocation or repair due to
impact damage.
Safety: Secures fixture to structure in case of
conduit failure.
“EZ” Mount Adapter
HIGH WATTAGE VM4L
AVAILABLE 2011
LED
TECHNOLOGY
Certified - File LR11713
VM1L SERIES LIGHTING
REDUCED PROFILE LED 45 WATT L37
L
Options
F—Single Fuse5
FF—Double Fuse5
TBX—Terminal Blocks
X= Variations
(May be alphanumeric
to indicate terminals)
P1—Photocell 120V6
Factory Installed
P2—Photocell 208-277V6
Factory Installed
QD—QD Wired at Ballast7
CP—Component Pack
(Tank w/mount,
optic, guard - LED’s
included in tank)
AN—Assembled
(Tank w/mount,
optic, guard- LED’s
included in tank)
®
CertiL i t e ®VLED Catalog Number Logic
Housing Series
5-1/2" thread w/driver
and LED’s
Voltage
30—120-277VAC 50/60 Hz
Mounting Type
A—Pendant
X—Ceiling
B—Wall Bracket
C—Cone Top
E—EZ Mount Adapter1
D—Stanchion 25°
S—Stanchion Straight 90°
N—None (mount ordered separately)2
Lamp Wattage
45—approx. VA (wattage)
of driver and LED’s
Guard
G—Guard
(Globes & Glass refractors)
N—No Guard
Optic
GL—Globe
R1—Type I Refractor (all glass)
R5—Type V Refractor (all glass)
S8—Type V 8" Spin-Top Refractor
S5—Type V12" Spin-Top Refractor
TG—Teflon®3Coated Globe
T1—Teflon®3Coated Type I Refractor (all glass)
T5—Teflon®3Coated Type V Refractor (all glass)
T8—Teflon®3Coated Type V 8" Spin-Top Refractor
TV—Teflon®Coated Type V 12" Spin-Top Refractor
Entry (Mounts available)
2—3/4" NPT (A,B,C,X)
3—1" NPT (A,B,C,X)
4—1 1/4" NPT (D,S)
5—1 1/2" NPT (D,S)
6—3/4" NPT 5-Hub (X)
7—1" NPT 5-Hub (X)
8—M20 4-Hub (X)
9—M20 5-Hub (X)
Z—EZ Mount Adapter1
N—None (mount ordered separately)2
VM1L 45 30 0 0 00 0 (NR4) 00
1Completes as “EZ”, conduit mounting boxes ordered separately -
See L39.
2NN mount ordered separately.
3Teflon®is a registered trademark of DuPont, Inc.
4Restricted Breathing - See L39 for more information.
5Fusing not for Marine or Canadian installations.
6Photo cells for Class I, Div. 2 only.
7QD = Quick Disconnect. Allows easy tank removal for maintenance.
Electrician simply unplugs tank from mount for fixture relocation or
repair due to impact damage.
VM1L SERIES LIGHTING
REDUCED PROFILE LED 45 WATT
L38
ORDERING INFORMATION
CEILING
PENDANT WALL CONE
1Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VM1L4530A2GLN
2Catalog numbers shown are with 3/4" conduit openings; change “2” to “3” for 1" e.g. VM1L4530A3GLG
3120VAC through 277VAC 50/60Hz
VM1L SERIES PENDANT WITH OPTIC AND GUARD1
WATTS HUB SIZE2VOLTAGE3GLOBE & GUARD TYPE I GLASS TYPE V GLASS 8" SPIN-TOP TYPE V 12" SPIN-TOP TYPE V
REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD
45 3/4" 120-277VAC VM1L4530A2GLG VM1L4530A2R1G VM1L4530A2R5G VM1L4530A2S8G VM1L4530A2S5G
WATTS HUB SIZE2VOLTAGE3GLOBE & GUARD TYPE I GLASS TYPE V GLASS 8" SPIN-TOP TYPE V 12" SPIN-TOP TYPE V
REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD
45 3/4" 120-277VAC VM1L4530X2GLG VM1L4530X2R1G VM1L4530X2R5G VM1L4530X2S8G VM1L4530X2S5G
VM1L SERIES CEILING WITH OPTIC AND GUARD1
WATTS HUB SIZE2VOLTAGE3GLOBE & GUARD TYPE I GLASS TYPE V GLASS 8" SPIN-TOP TYPE V 12" SPIN-TOP TYPE V
REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD
45 3/4" 120-277VAC VM1L4530B2GLG VM1L4530B2R1G VM1L4530B2R5G VM1L4530B2S8G VM1L4530B2S5G
VM1L SERIES WALL WITH OPTIC AND GUARD1
WATTS HUB SIZE2VOLTAGE3GLOBE & GUARD TYPE I GLASS TYPE V GLASS 8" SPIN-TOP TYPE V 12" SPIN-TOP TYPE V
REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD
45 3/4" 120-277VAC VM1L4530C2GLG VM1L4530C2R1G VM1L4530C2R5G VM1L4530C2S8G VM1L4530C2S5G
VM1L SERIES CONE WITH OPTIC AND GUARD1
VM1L SERIES LIGHTING
REDUCED PROFILE LED 45 WATT L39
ORDERING INFORMATION
L
STANCHION STRAIGHT
STANCHION 25° EZ ADAPTER
1Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VM1L4530D5GLN
2Catalog numbers shown are with 1-1/2" conduit openings; change “5” to “4” for 1-1/4" e.g. VM1L4530D4GLG
3120VAC through 277VAC 50/60Hz
4VMEZA tank adapters UL “classified” as an assembly for use between VM tanks and EZ mounts. Order EZ mounts separately (see below).
VM1L SERIES 25° STANCHION WITH OPTIC AND GUARD1
WATTS HUB SIZE2VOLTAGE3GLOBE & GUARD TYPE I GLASS TYPE V GLASS 8" SPIN-TOP TYPE V 12" SPIN-TOP TYPE V
REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD
45 1-1/2" 120-277VAC VM1L4530D5GLG VM1L4530D5R1G VM1L4530D5R5G VM1L4530D5S8G VM1L4530D5S5G
WATTS HUB SIZE2VOLTAGE3GLOBE & GUARD TYPE I GLASS TYPE V GLASS 8" SPIN-TOP TYPE V 12" SPIN-TOP TYPE V
REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD
45 1-1/2" 120-277VAC VM1L4530S5GLG VM1L4530S5R1G VM1L4530S5R5G VM1L4530S5S8G VM1L4530S5S5G
VM1L SERIES STRAIGHT STANCHION WITH OPTIC AND GUARD1
WATTS HUB SIZE4VOLTAGE3GLOBE & GUARD TYPE I GLASS TYPE V GLASS 8" SPIN-TOP TYPE V 12" SPIN-TOP TYPE V
REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD REFRACTOR & GUARD
45 4120-277VAC VM1L4530EZGLG VM1L4530EZR1G VM1L4530EZR5G VM1L4530EZS8G VM1L4530EZS5G
VM1L SERIES EZ ADAPTER WITH OPTIC AND GUARD1
HUB SIZE
3/4"
1"
1-1/4"/1-1/2"*
CATALOG NUMBER
PENDANT CEILING BRACKET STANCHION
EZA2 EZX2 EZB2
EZA3 EZX3 EZB3
—— — EZD4A*
MOUNTING BOXES FOR EZ ADAPTER
Wall Bracket 25° Stanchion
Pendant Ceiling
*1-1/2" furnished with 1-1/2"-1-1/4" reducer and extension.
VM1L SERIES LIGHTING
COMPONENT PARTS / ELECTRICAL & TEMPERATURE DATA
L40
CERTILITE®VVM MOUNTING SPLICE BOXES
3/4"
1"
1-1/4"
1-1/2"
M-20
HUB SIZE
VMA2B
VMA3B
PENDANT
VMX2B
VMX3B
VMX8B**
CEILING 4 HUB
VMX6B
VMX7B
VMX9B
CEILING 5 HUB
VMB2B
VMB3B
WALL
VMC2B
VMC3B
CONE TOP
VMD4B
VMD5B
25 DEGREE STANCHION
VMS4B
VMS5B
90 DEGREE STANCHION
CATALOG NUMBER
Pendant Ceiling Wall
25° Stanchion
Cone Top
Straight Stanchion EZ Adapter*
VMEZA
*VMEZA is used between a ballast tank and an EZ mount-ordered separately. See L39 for more info.
**VMX8B furnished with 3 non-metallic plugs.
VMG17
VMRWG85
VZRG1550 VZRG2550
VMAG17
VMR175
VMR171
VMRWGS5
VMPA40
VMPSD40 VMFSPC1
O
P
T
I
C
S
A
C
C
E
S
S
O
R
I
E
S
DESCRIPTION OPTIC LOGIC GUARD
VM1L LED OPTICS AND ACCESSORIES
Globe (glass)
Refractor (all glass) Type I
Refractor (all glass) Type V
Refractor (spin top) 8" Type V
Refractor (spin top) 12" Type V
Globe Teflon®1coated
Refractor Teflon®coated (all glass) Type I
Refractor Teflon®coated (all glass) Type V
Refractor (spin top) Teflon®coated 8" Type V
Refractor (spin top) Teflon®coated 12" Type V
DOME REFLECTOR (fiberglass reinforced polyester)
ANGLE REFLECTOR (fiberglass reinforced polyester)
120VAC Photocell with FS Style Cover
208-277VAC Photocell with FS Style Cover
3-sided EXIT Accessory (use without guard)
Tank adapter to Crouse-Hinds®VM Series mounts*
VMG17 (GL)
VMR171 (R1)
VMR175 (R5)
VZRG1550 (S8)
VZRG2550 (S5)
VMG17T
VMR171T (T1)
VMR175T (T5)
VZRG1550T (T8)
VZRG2550T (TV)
VMPSD40
VMPA40
VMFSPC1
VMFSPC2
VEXA100B
VMCHVM
VMAG17
VMAG17
VMAG17
VMRWG8
VMRWGS
VMAG17
VMAG17
VMAG17
VMRWG8
VMRWGS
NA
NA
NA
NA
NA
NA
1Teflon is a registered trademark of DuPont, Inc.
* See page L223 for more information.
CAT. NO. VOLTAGE 50/60HZ WATTAGE AMPS 120/277 CIL3WEIGHT
VM1L LED HOUSINGS WITH DRIVERS AND LEDS - ELECTRICAL RATINGS
VM1L4530 120-277VAC 48.4 .416/.180 3960 15.5 LBS
CAT. NO. AMBIENT C1D2 C1Z2 NR C2D1 L70 SUPPLY WIRE
THERMAL PERFORMANCE DATA (ANY OPTIC)
VM1L4530 40OC T4A T6 T4(EFG) 55,000 HRS 75OC
VM1L4530 55OC T4 T6 T4(EFG) 50,000 HRS 90OC
3CIL = Calculated Initial Lumens of LED component based on mfg. data and driver current INSIDE the optic. This value is provided as a reference only for compari-
son to traditional light sources such as incandescent, HID, or fluorescent which use initial values in “relative” photometry. KILLARK LED luminaires are tested using
the Absolute photometry method (LM79-08), which calculates delivered lumens only. KILLARK’s LED luminaires provide very bright white 5000OK (CCT) color and
can appear brighter than traditional light sources with higher lumen values under both photopic and scotopic conditions.
4Driver THD < 20%, Powerfactor 99% @ 120V; Line Regulation 2%; Load regulation 5%; Protected against Over-voltage and Over-current.
5VMRWG8 Plated Steel, VMRWGS 316 Stainless Steel.
VEXA100B
Tank Adapter
VMAG17
VM1L SERIES LIGHTING
DIMENSIONS / PHOTOMETRIC DATA L41
L
hole dia. .30"
(7.62)
13.55
(344)
13.67
(347)
6.88
(175)
1.70
(43)
2.56
(65)
6.38
(162)
4.33
(110)
12.07
(307)
5.31 DIA.
(135)
1.25
(32)
11.35 DIA.
(299)
6.38
(162)
10.77
(274)
8.21
(208)
7.74
(197)
10.77
(274)
6.75
(171)
13.58
(345)
6.38
(162)
8.21
(208)
7.74
(197)
2.63
(67)
10.78
(274)
10.77
(274) 8.21
(208)
7.74
(197)
5.62
(143)
13.58
(345)
6.38
(162)
13.34
(339)
14.75 DIA
(375)
16.87 DIA.
(428)
hole dia.
.34"
(8.63)
VM1L Tank with 8" Spin-top Refractor
VM1L Tank with 12" Spin-top Refractor
VM1L Tank with Angle Refractor
VM1L Tank Globe & Guard
VM1L Tank with Dome Refractor
VM1L Tank w/Pendant Mount & Globe
LED 45 Watt Globe Only
8.82
(275) 8.25
(210)
12.73
(323)
10.17
(258)
13.58
(345)
6.38
(162)
12.19
(310)
11.87 DIA.
(301)
8.16 DIA.
(207)
VM1L SERIES LIGHTING
PHOTOMETRIC DATA
L42
LED 45 Watt
Globe & Dome Reflector
LED 45 Watt
Globe & Type V Refractor
LED 45 Watt 12" Spin-top
Type V Refractor
VQ1F/VQ2F SERIES LIGHTING
CERTILITE®COMPACT FLUORESCENT FIXTURES 13-84 WATT L43
FEATURES-SPECIFICATIONS
L
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option2
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Applications:
CertiLite®VQ1F/VQ2F Series are designed for installations
where moisture, dirt, dust, corrosion and vibration may be pre-
sent, or NEMA 3 and 4X areas and where wind, water, snow or
high ambients can be expected. They can be used in locations
made hazardous by the presence of flammable vapors and
gases or combustible dusts, as defined by the NEC®. Typical
applications include manufacturing plants and certain chemical
and petrochemical processing facilities, sewage treatment
plants, off-shore and dockside installations, garages and ware-
houses.
Standard Materials:
Ballast tank and splice box – corrosion resistant copper-free alu-
minum alloy with baked powder epoxy/polyester finish, electrosta-
tically applied for complete, uniform corrosion protection.
All external hardware – 316 stainless steel.
Guards – Painted copper-free aluminum alloy or 316SS for 7-3/4"
glass optics and Enclosed Reflectors.
Reflectors – lightweight, corrosion resistant fiberglass reinforced
polyester, or copper-free aluminum.
Features:
“World Voltage” Ballast 120 through 277 VAC 50/60Hz
Six mounting splice box types: Pendant, Ceiling, Wall bracket,
Cone Top, 25° Angle Stanchion, Straight Stanchion – in a variety
of entry sizes, including M20 for the VMX ceiling style.
Elevated ambients to 55°C 13W–64W
Two lamp models have 2 ballasts for separate switching or system
redundancy
Normally shipped as components for fast delivery, or may be
ordered factory assembled.
Options for Fuses and Quick Disconnect
Tank assemblies include quad-pin lamp
Compliances
UL1598 Standard for luminaires
UL1598A Marine type luminaire
UL-844 Standard for lighting fixtures for hazardous locations
CSA C22.2 no. 137-M1981 electric luminaries for use in
hazardous locations
F E AT U R E S BENEFITS
Swing-Barrel Nut
Patented Tank
Mounting System
• Stainless-to-Stainless securement
• Takes load off during installation
• Uses ordinary tools
• Saves time and labor
Sealed Optic Zone 2
AEx nAR Restricted
Breathing (suffix NR)
NO External Seals. Lower T-codes, Suitable
for Class I Div. 2 Classified areas per the
NEC®. See L54 for more info.
All glass refractors Compact (5-1/2" thread size, types I & V)
Standard (7-3/4", thread size,types I, III, V)
Enhances user selection flexibility
“EZ” mount adapter Easier Maintenance, saves labor, move
fixture from the ladder to the workbench
Photo controls -
Class I Div. 2 /
N4X areas
Available as Field or Factory Installed to
save energy when light not required
Earthquake Tab -
Built-in attachment
point for safety cables
Safety: Secures fixture to structure in case
of conduit failure. “3rd hand” acces-
sories for lamp change out. See L53
for more info.
“FULL CUTOFF” &
CUTOFF Optics
For “Dark Sky” Requirements. Helps to
minimize offending light pollution. See L56
for more info.
VMEP40
“Food Optic”
VQ2F
Expanded Offering for Food or Grain
Handling Applications to minimize
contamination. See L55 for more info.
I III V
Certified - File LR11713
VM1/Wall
Globe & Guard
VM1/Pendant
Globe & Guard
VM2/Ceiling
Globe & Guard
VM2/Stanchion 25°
Refractor & Guard
Compliances Continued:
Enclosed and gasketed
NEMA 3, 4X IP66
UL 60079-15 - Electrical apparatus for Explosive Gas
Atmospheres with Type of Protection “n” (Restricted Breathing
and non-sparking).
Note: VQ1F dimensions are the same as VM1 and VQ2F are same as VM2 -
See L100-L103.
Replaces
VBF/VQF
Series
NEW!
VQ1F/VQ2F SERIES LIGHTING
CATALOG ORDERING LOGIC
L44
CertiL i t e ®Catalog Number Logic; 13-84 W Compact Fluorescent Fixtures
Series Constant
Optic Thread Size
1F—5 1/2"
2F—7 3/4"
Voltage
30—120/277VAC
Mounting Type
A—Pendant
X—Ceiling
B—Wall Bracket
C—Cone Top
E—EZ Mount Adapter1
D—Stanchion 25°
S—Stanchion Straight 90°
N—None (mount ordered
separately)2
Lamp Wattage
131 x 13
181 x 18
26S—1 x 26
321 x 32
421 x 42
262 x 13
362 x 18
522 x 26
642 x 32
842 x 42
Options
NR7
F—Single Fuse5
FF—Double Fuse5
TBx—Terminal Blocks5
P1—Photocell 120V6
P2—Photocell 208-277V6
QD—Quick Disconnect9
CP—Component Pack
AN—Assembled–no lamps
Optic
GL—Globe (VQ1F, VQ2F)
R1—Type I Glass Refractor (VQ1F,
VQ2F)
R3—Type III Glass Refractor (VQ2F)
R5—Type V Glass Refractor (VQ1F,
VQ2F)
ER—Enclosed Reflector (VQ2F)
EP—Poylcarbonate Shielded
Enclosed Reflector (VQ2F)8
S2—Type II 12" Spin-Top Refractor
(VQ1F, VQ2F)
S8—Type V 8" Spin-Top Refractor
(VQ1F)
S5—Type V 12" Spin-Top Refractor
(VQ1F, VQ2F)
P5—Type V 12" Plastic Spin-Top
Refractor (VQ1F)
FG—Silicone3Coated Globe
(VQ1F, VQ2F)
TG—Teflon®4Coated Globe (VQ1F,
VQ2F)
T1—Teflon®4Coated Globe Type I
Glass Refractor (VQ1F, VQ2F)
T3—Teflon®4Coated Globe Type III
Glass Refractor (VQ2F)
T5—Teflon®4Coated Globe Type V
Glass Refractor (VQ1F, VQ2F)
T2—Teflon®4Coated Type II 12"
Spin-Top Refractor (VQ1F,
VQ2F)
T8—Teflon®4Coated Type V 8"
Spin-Top Refractor (VQ1F)
TV—Teflon®4Coated Type V 12"
Spin-Top Refractor (VQ1F,
VQ2F)
Entry (Mounts available)
2—3/4" NPT (A,B,C,X)
3—1" NPT (A,B,C,X)
4—1 1/4" NPT (D,S)
5—1 1/2" NPT (D,S)
6—3/4" NPT 5-Hub (X)
7—1" NPT 5-Hub (X)
8—M20 4-Hub (X)
9—M20 5-Hub (X)
Z—EZ Mount Adapter1
N—None (mount ordered
separately)2
VQ 1F 84 30 A 3 R1 G (NR7)
1Completes as “EZ”, conduit mounting boxes ordered separately - See L83.
2NN mount ordered separately.
3Silicone coated globe for additional impact protection.
4Teflon®is a registered trademark of DuPont, Inc.
5Fusing not for Marine or Canadian installations.
6Photo cells for Class I, Div. 2 only
7Restricted Breathing - See L54 for more information.
8Not for use with wall or straight (90°) Stanchion.
9QD = Quick Disconnect. Allows easy tank removal for maintenance.
Electrician simply unplugs de-energized ballast from supply circuit.
Guard
G—With Guard
N—Without Guard
VQ1F/VQ2F SERIES LIGHTING
CERTILITE®COMPACT FLUORESCENT FIXTURES L45
L
VM1 Ceiling
w/5-1/2"
Globe & Guard
VM1 Pendant
w/5-1/2"
Globe & Guard
VM2 Pendant
w/7-3/4"
Globe & Guard
VM2 Ceiling
w/7-3/4"
Globe & Guard
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Certified - File LR11713
VQ1F - VQ2F 13 - 84 WATT COMPACT FLUORESCENT - CEILING
WATTS
DESCRIPTION
LAMPS
INCL.
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE
V REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
13 1X13 3/4" VQ1F1330X2GLG VQ1F1330X2R1G VQ1F1330X2R5G VQ2F1330X2GLG VQ2F1330X2R1G VQ2F1330X2R5G VQ2F1330X2S5G
18 1X18 3/4" VQ1F1830X2GLG VQ1F1830X2R1G VQ1F1830X2R5G VQ2F1830X2GLG VQ2F1830X2R1G VQ2F1830X2R5G VQ2F1830X2S5G
26 1X26 3/4" VQ1F26S30X2GLG VQ1F26S30X2R1G VQ1F26S30X2R5G VQ2F26S30X2GLG VQ2F26S30X2R1G VQ2F26S30X2R5G VQ2F26S30X2S5G
32 1X32 3/4" VQ1F3230X2GLG VQ1F3230X2R1G VQ1F3230X2R5G VQ2F3230X2GLG VQ2F3230X2R1G VQ2F3230X2R5G VQ2F3230X2S5G
42 1X42 3/4" VQ1F4230X2GLG VQ1F4230X2R1G VQ1F4230X2R5G VQ2F4230X2GLG VQ2F4230X2R1G VQ2F4230X2R5G VQ2F4230X2S5G
26 2X13 3/4" VQ1F2630X2GLG VQ1F2630X2R1G VQ1F2630X2R5G VQ2F2630X2GLG VQ2F2630X2R1G VQ2F2630X2R5G VQ2F2630X2S5G
36 2X18 3/4" VQ1F3630X2GLG VQ1F3630X2R1G VQ1F3630X2R5G VQ2F3630X2GLG VQ2F3630X2R1G VQ2F3630X2R5G VQ2F3630X2S5G
52 2X26 3/4" VQ1F5230X2GLG VQ1F5230X2R1G VQ1F5230X2R5G VQ2F5230X2GLG VQ2F5230X2R1G VQ2F5230X2R5G VQ2F5230X2S5G
64 2X32 3/4" VQ1F6430X2GLG VQ1F6430X2R1G VQ1F6430X2R5G VQ2F6430X2GLG VQ2F6430X2R1G VQ2F6430X2R5G VQ2F6430X2S5G
84 2X42 3/4" VQ1F8430X2GLG VQ1F8430X2R1G VQ1F8430X2R5G VQ2F8430X2GLG VQ2F8430X2R1G VQ2F8430X2R5G VQ2F8430X2S5G
120VAC
THROUGH
227VAC
50/60Hz
VQ1F - VQ2F 13 - 84 WATT COMPACT FLUORESCENT - PENDANT
WATTS
DESCRIPTION
LAMPS
INCL.
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE
V REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
13 1X13 3/4" VQ1F1330A2GLG VQ1F1330A2R1G VQ1F1330A2R5G VQ2F1330A2GLG VQ2F1330A2R1G VQ2F1330A2R5G VQ2F1330A2S5G
18 1X18 3/4" VQ1F1830A2GLG VQ1F1830A2R1G VQ1F1830A2R5G VQ2F1830A2GLG VQ2F1830A2R1G VQ2F1830A2R5G VQ2F1830A2S5G
26 1X26 3/4" VQ1F26S30A2GLG VQ1F26S30A2R1G VQ1F26S30A2R5G VQ2F26S30A2GLG VQ2F26S30A2R1G VQ2F26S30A2R5G VQ2F26S30A2S5G
32 1X32 3/4" VQ1F3230A2GLG VQ1F3230A2R1G VQ1F3230A2R5G VQ2F3230A2GLG VQ2F3230A2R1G VQ2F3230A2R5G VQ2F3230A2S5G
42 1X42 3/4" VQ1F4230A2GLG VQ1F4230A2R1G VQ1F4230A2R5G VQ2F4230A2GLG VQ2F4230A2R1G VQ2F4230A2R5G VQ2F4230A2S5G
26 2X13 3/4" VQ1F2630A2GLG VQ1F2630A2R1G VQ1F2630A2R5G VQ2F2630A2GLG VQ2F2630A2R1G VQ2F2630A2R5G VQ2F2630A2S5G
36 2X18 3/4" VQ1F3630A2GLG VQ1F3630A2R1G VQ1F3630A2R5G VQ2F3630A2GLG VQ2F3630A2R1G VQ2F3630A2R5G VQ2F3630A2S5G
52 2X26 3/4" VQ1F5230A2GLG VQ1F5230A2R1G VQ1F5230A2R5G VQ2F5230A2GLG VQ2F5230A2R1G VQ2F5230A2R5G VQ2F5230A2S5G
64 2X32 3/4" VQ1F6430A2GLG VQ1F6430A2R1G VQ1F6430A2R5G VQ2F6430A2GLG VQ2F6430A2R1G VQ2F6430A2R5G VQ2F6430A2S5G
84 2X42 3/4" VQ1F8430A2GLG VQ1F8430A2R1G VQ1F8430A2R5G VQ2F8430A2GLG VQ2F8430A2R1G VQ2F8430A2R5G VQ2F8430A2S5G
120VAC
THROUGH
227VAC
50/60Hz
1See hazardous application data on page L49 for application suitability.
2Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VQ1F1330A2GLN.
3Catalog numbers shown are with 3/4" conduit openings; change “2” to “3” for 1"; e.g. VQ1F1330A3GLG.
4Ballasts are electronic for included Quad-Pin Lamps and 120VAC through 277VAC operation.
5Add suffix NR for AEx nR Restricted Breathing; see page L54 for more information.
VQ1F/VQ2F SERIES LIGHTING
CERTILITE®COMPACT FLUORESCENT FIXTURES
L46
VM1 EZ Adapter
w/5-1/2"
Globe & Guard
VM1 Wall
w/5-1/2"
Globe & Guard
VM2 Wall
w/7-3/4"
Globe & Guard
VM2 EZ Adapter
w/7-3/4"
Globe & Guard
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Certified - File LR11713
VQ1F - VQ2F 13 - 84 WATT COMPACT FLUORESCENT - EZ ADAPTER6
DESCRIPTION
LAMPS
INCL.
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE
V REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
VQ1F - VQ2F 13 - 84 WATT COMPACT FLUORESCENT - WALL
DESCRIPTION
LAMPS
INCL.
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE
V REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
1See hazardous location data on page L49 for application suitability.
2Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VQ1F1330B2GLN.
3Catalog numbers shown are with 3/4" conduit openings; change “2” to “3” for 1"; e.g. VQ1F1330B3GLG.
4Ballasts are electronic for included Quad-Pin Lamps and 120VAC through 277VAC operation.
5Add suffix NR for AEx nR Restricted Breathing; see page L54 for more information.
6VMEZA tank adapters “classified” as an assembly for use between VM type tanks and EZ mounts. Order EZ mounts separately.
WATTS
WATTS
13 1X13 3/4" VQ1F1330B2GLG VQ1F1330B2R1G VQ1F1330B2R5G VQ2F1330B2GLG VQ2F1330B2R1G VQ2F1330B2R5G VQ2F1330B2S5G
18 1X18 3/4" VQ1F1830B2GLG VQ1F1830B2R1G VQ1F1830B2R5G VQ2F1830B2GLG VQ2F1830B2R1G VQ2F1830B2R5G VQ2F1830B2S5G
26 1X26 3/4" VQ1F26S30B2GLG VQ1F26S30B2R1G VQ1F26S30B2R5G VQ2F26S30B2GLG VQ2F26S30B2R1G VQ2F26S30B2R5G VQ2F26S30B2S5G
32 1X32 3/4" VQ1F3230B2GLG VQ1F3230B2R1G VQ1F3230B2R5G VQ2F3230B2GLG VQ2F3230B2R1G VQ2F3230B2R5G VQ2F3230B2S5G
42 1X42 3/4" VQ1F4230B2GLG VQ1F4230B2R1G VQ1F4230B2R5G VQ2F4230B2GLG VQ2F4230B2R1G VQ2F4230B2R5G VQ2F4230B2S5G
26 2X13 3/4" VQ1F2630B2GLG VQ1F2630B2R1G VQ1F2630B2R5G VQ2F2630B2GLG VQ2F2630B2R1G VQ2F2630B2R5G VQ2F2630B2S5G
36 2X18 3/4" VQ1F3630B2GLG VQ1F3630B2R1G VQ1F3630B2R5G VQ2F3630B2GLG VQ2F3630B2R1G VQ2F3630B2R5G VQ2F3630B2S5G
52 2X26 3/4" VQ1F5230B2GLG VQ1F5230B2R1G VQ1F5230B2R5G VQ2F5230B2GLG VQ2F5230B2R1G VQ2F5230B2R5G VQ2F5230B2S5G
64 2X32 3/4" VQ1F6430B2GLG VQ1F6430B2R1G VQ1F6430B2R5G VQ2F6430B2GLG VQ2F6430B2R1G VQ2F6430B2R5G VQ2F6430B2S5G
84 2X42 3/4" VQ1F8430B2GLG VQ1F8430B2R1G VQ1F8430B2R5G VQ2F8430B2GLG VQ2F8430B2R1G VQ2F8430B2R5G VQ2F8430B2S5G
120VAC
THROUGH
227VAC
50/60Hz
VQ1F1330EZGLG VQ1F1330EZR1G VQ1F1330EZR5G VQ2F1330EZGLG VQ2F1330EZR1G VQ2F1330EZR5G VQ2F1330EZS5G
VQ1F1830EZGLG VQ1F1830EZR1G VQ1F1830EZR5G VQ2F1830EZGLG VQ2F1830EZR1G VQ2F1830EZR5G VQ2F1830EZS5G
VQ1F26S30EZGLG VQ1F26S30EZR1G VQ1F26S30EZR5G VQ2F26S30EZGLG VQ2F26S30EZR1G VQ2F26S30EZR5G VQ2F26S30EZS5G
VQ1F3230EZGLG VQ1F3230EZR1G VQ1F3230EZR5G VQ2F3230EZGLG VQ2F3230EZR1G VQ2F3230EZR5G VQ2F3230EZS5G
VQ1F4230EZGLG VQ1F4230EZR1G VQ1F4230EZR5G VQ2F4230EZGLG VQ2F4230EZR1G VQ2F4230EZR5G VQ2F4230EZS5G
VQ1F2630EZGLG VQ1F2630EZR1G VQ1F2630EZR5G VQ2F2630EZGLG VQ2F2630EZR1G VQ2F2630EZR5G VQ2F2630EZS5G
VQ1F3630EZGLG VQ1F3630EZR1G VQ1F3630EZR5G VQ2F3630EZGLG VQ2F3630EZR1G VQ2F3630EZR5G VQ2F3630EZS5G
VQ1F5230EZGLG VQ1F5230EZR1G VQ1F5230EZR5G VQ2F5230EZGLG VQ2F5230EZR1G VQ2F5230EZR5G VQ2F5230EZS5G
VQ1F6430EZGLG VQ1F6430EZR1G VQ1F6430EZR5G VQ2F6430EZGLG VQ2F6430EZR1G VQ2F6430EZR5G VQ2F6430EZS5G
VQ1F8430EZGLG VQ1F8430EZR1G VQ1F8430EZR5G VQ2F8430EZGLG VQ2F8430EZR1G VQ2F8430EZR5G VQ2F8430EZS5G
120VAC
THROUGH
227VAC
50/60Hz
13 1X13 6
18 1X18 6
26 1X26 6
32 1X32 6
42 1X42 6
26 2X13 6
36 2X18 6
52 2X26 6
64 2X32 6
84 2X42 6
VQ1F/VQ2F SERIES LIGHTING
CERTILITE®COMPACT FLUORESCENT FIXTURES L47
L
1See hazardous location data on page L49 for application suitability.
2Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VQ1F1330D5GLN.
3Catalog numbers shown are with 1-1/2" conduit openings; change “5” to “4” for 1-1/4"; e.g. VQ1F1330D4GLG.
4Ballasts are electronic for included Quad-Pin Lamps and 120VAC through 277VAC operation.
5Add suffix NR for AEx nR Restricted Breathing; see page L54 for more information.
VM1 Stanchion 25°
w/5-1/2"
Globe & Guard
VM2 Stanchion 25°
w/7-3/4"
Globe & Guard
VM2 Stanchion
Straight
w/7-3/4"
Globe & Guard
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Certified - File LR11713
VQ1F - VQ2F 13 - 84 WATT COMPACT FLUORESCENT - STANCHION 25° ANGLE
DESCRIPTION
LAMPS
INCL.
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE
V REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
13 1X13 3/4" VQ1F1330D5GLG VQ1F1330D5R1G VQ1F1330D5R5G VQ2F1330D5GLG VQ2F1330D5R1G VQ2F1330D5R5G VQ2F1330D5S5G
18 1X18 3/4" VQ1F1830D5GLG VQ1F1830D5R1G VQ1F1830D5R5G VQ2F1830D5GLG VQ2F1830D5R1G VQ2F1830D5R5G VQ2F1830D5S5G
26 1X26 3/4" VQ1F26S30D5GLG VQ1F26S30D5R1G VQ1F26S30D5R5G VQ2F26S30D5GLG VQ2F26S30D5R1G VQ2F26S30D5R5G VQ2F26S30D5S5G
32 1X32 3/4" VQ1F3230D5GLG VQ1F3230D5R1G VQ1F3230D5R5G VQ2F3230D5GLG VQ2F3230D5R1G VQ2F3230D5R5G V12F3230D5S5G
42 1X42 3/4" VQ1F4230D5GLG VQ1F4230D5R1G VQ1F4230D5R5G VQ2F4230D5GLG VQ2F4230D5R1G VQ2F4230D5R5G VQ2F4230D5S5G
26 2X13 3/4" VQ1F2630D5GLG VQ1F2630D5R1G VQ1F2630D5R5G VQ2F2630D5GLG VQ2F2630D5R1G VQ2F2630D5R5G VQ2F2630D5S5G
36 2X18 3/4" VQ1F3630D5GLG VQ1F3630D5R1G VQ1F3630D5R5G VQ2F3630D5GLG VQ2F3630D5R1G VQ2F3630D5R5G VQ2F3630D5S5G
52 2X26 3/4" VQ1F5230D5GLG VQ1F5230D5R1G VQ1F5230D5R5G VQ2F5230D5GLG VQ2F5230D5R1G VQ2F5230D5R5G VQ2F5230D5S5G
64 2X32 3/4" VQ1F6430D5GLG VQ1F6430D5R1G VQ1F6430D5R5G VQ2F6430D5GLG VQ2F6430D5R1G VQ2F6430D5R5G VQ2F6430D5S5G
84 2X42 3/4" VQ1F8430D5GLG VQ1F8430D5R1G VQ1F8430D5R5G VQ2F8430D5GLG VQ2F8430D5R1G VQ2F8430D5R5G VQ2F8430D5S5G
120VAC
THROUGH
227VAC
50/60Hz
VQ1F - VQ2F 13 - 84 WATT COMPACT FLUORESCENT - STANCHION STRAIGHT
DESCRIPTION
LAMPS
INCL.
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE
V REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
13 1X13 1-1/2" VQ1F1330S5GLG VQ1F1330S5R1G VQ1F1330S5R5G VQ2F1330S5GLG VQ2F1330S5R1G VQ2F1330S5R5G VQ2F1330S5S5G
18 1X18 1-1/2" VQ1F1830S5GLG VQ1F1830S5R1G VQ1F1830S5R5G VQ2F1830S5GLG VQ2F1830S5R1G VQ2F1830S5R5G VQ2F1830S5S5G
26 1X26 1-1/2" VQ1F26S30S5GLG VQ1F26S30S5R1G VQ1F26S30S5R5G VQ2F26S30S5GLG VQ2F26S30S5R1G VQ2F26S30S5R5G VQ2F26S30S5S5G
32 1X32 1-1/2" VQ1F3230S5GLG VQ1F3230S5R1G VQ1F3230S5R5G VQ2F3230S5GLG VQ2F3230S5R1G VQ2F3230S5R5G VQ2F3230S5S5G
42 1X42 1-1/2" VQ1F4230S5GLG VQ1F4230S5R1G VQ1F4230S5R5G VQ2F4230S5GLG VQ2F4230S5R1G VQ2F4230S5R5G VQ2F4230S5S5G
26 2X13 1-1/2" VQ1F2630S5GLG VQ1F2630S5R1G VQ1F2630S5R5G VQ2F2630S5GLG VQ2F2630S5R1G VQ2F2630S5R5G VQ2F2630S5S5G
36 2X18 1-1/2" VQ1F3630S5GLG VQ1F3630S5R1G VQ1F3630S5R5G VQ2F3630S5GLG VQ2F3630S5R1G VQ2F3630S5R5G VQ2F3630S5S5G
52 2X26 1-1/2" VQ1F5230S5GLG VQ1F5230S5R1G VQ1F5230S5R5G VQ2F5230S5GLG VQ2F5230S5R1G VQ2F5230S5R5G VQ2F5230S5S5G
64 2X32 1-1/2" VQ1F6430S5GLG VQ1F6430S5R1G VQ1F6430S5R5G VQ2F6430S5GLG VQ2F6430S5R1G VQ2F6430S5R5G VQ2F6430S5S5G
84 2X42 1-1/2" VQ1F8430S5GLG VQ1F8430S5R1G VQ1F8430S5R5G VQ2F8430S5GLG VQ2F8430S5R1G VQ2F8430S5R5G VQ2F8430S5S5G
VM1 Stanchion
Straight
w/5-1/2"
Globe & Guard
120VAC
THROUGH
227VAC
50/60Hz
VQ1F/VQ2F SERIES LIGHTING
COMPONENTS/TECHNICAL DATA
L48
MOUNTING SPLICE BOXES
3/4"
1"
1-1/4"
1-1/2"
M-20
HUB SIZE
VMA2B
VMA3B
PENDANT
VMX2B
VMX3B
VMX8B**
CEILING 4 HUB
VMX6B
VMX7B
VMX9B
CEILING 5 HUB
VMB2B
VMB3B
WALL
VMC2B
VMC3B
CONE TOP
VMD4B
VMD5B
25 DEGREE STANCHION
VMS4B
VMS5B
90 DEGREE STANCHION
CATALOG NUMBER
*VMEZA is used between a ballast tank and an EZ mount-ordered separately. See L94 for more info.
**VMX8B furnished with 3 non-metallic plugs.
OPTICS AND GUARDS
Globe (glass) VMG17 VMAG17 VMG25 VMAG25S
Refractor (all glass) Type V VMR175 VMAG17 VMR255 VMAG25S
Refractor (all glass) Type I VMR1717VMAG17 VMR251 VMAG25S
Refractor (all glass) Type III ——VMG25 VMAG25S
Refractor (spin top glass) 8" Type V VZRG1550 VMRWG8 ——
Refractor (spin top glass) 12" Type V VZRG2550 VMRWG VZRG4050 VMRWG
Refractor (spin top glass) 12" Type II VZRG2520 VMRWG VZRG4020 VMRWG
Refractor (spin top plastic) 12" Type V VZRP175 VMRWG ——
Enclosed Refractor (glass lens) ——VMER40 VMERG
Enclosed Refractor (plastic lens) ——VMEP40 —
VQ1F LOW WATTAGE VQ2F LOW WATTAGE
5-1/2" OPTIC THREAD SIZE 7-3/4" OPTIC THREAD SIZE
DESCRIPTION OPTICS GUARD OPTICS GUARD
* See L95 for full selection and information.
BALLAST TANKS ONLY 120VAC THROUGH 277VAC 50/60HZ
VQIF1330 VQ2F1330 13 1X13
VQIF1830 VQ2F1830 18 1X18
VQIF26S30 VQ2F26S30 26 1X26
VQIF3230 VQ2F3230 32 1X32
VQIF4230 VQ2F4230 42 1X42
VQIF2630 VQ2F2630 26 2X13
VQIF3630 VQ2F3630 36 2X18
VQIF5230 VQ2F5230 52 2X26
VQIF6430 VQ2F6430 64 2X32
VQIF8430 VQ2F8430 84 2X42
2Order splice box, optic and guard separately.
3See pages L98, L99 for ballast data.
CATALOG NUMBER
5-1/2" OPTIC 7-3/4" OPTIC WATTS LAMPS INCL.
REPLACEMENT LAMPS
MQL13 13W Quad-Pin
MQL18 18W Quad-Pin
MQL26 26W Quad-Pin
MQL32 32W Quad-Pin
MQL42 42W Quad-Pin
CATALOG NUMBER DESC RIPTION
LUMEN OUTPUT
13 Watt (1X13) 900
18 Watt (1X18) 1200
26 Watt (1X26) 1800
32 Watt (1X32) 2400
42 Watt (1X42) 3200
26 Watt (2X13) 1800
36 Watt (2X18) 2400
52 Watt (2X26) 3600
64 Watt (2X32) 4800
84 Watt (2X42) 6400
LAMP SOURCE LUMEN OUTPUT
VBF/VBQ BALLAST DATA
13 Watt (1X13) 120-277 .144 (120)/.067 (277) HPF Electronic 5°F (-20°C)
18 Watt (1X18) .158 (120)/.073 (277) 5°F (-15°C)
26 Watt (1X26) .24 (120)/.11 (277)
32 Watt (1X32) 120-277 .31 (120)/.13 (277) HPF Electronic -4°F (-20°C) Watt
42 Watt (1X42) .38 (120)/.18 (277)
26 Watt (2X13) 120-277 .288 (120)/.134 (277) HPF Electronic
36 Watt (2X18) .316 (120)/.146 (277) 5°F (-15°C)
52 Watt (2X26) .48 (120)/.11 (277)
64 Watt (2X32) 120-277 .62 (120)/.26 (277) HPF Electronic -4°F (-20°C)
84 Watt (2X42) .76 (120)/.36 (277)
LAMP SOURCE LAMP WATTS/TYPE VOLTAGE 60HZ OPERATING (AMPS) BALLAST CIRCUIT REGULATION MIN. START
Quad-Pin
Fluorescent
NOTE: VQ1F dimensions are
the same as VMI; VQ2F dimen-
sions are the same as VM2. See
L100-L102.
T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
351-450 326-350 301-325 281-300 261-280 231-260 216-230 201-215 181-200 166-180 161-165 136-160 121-135 101-120 86-100 <=85
VQ1F/VQ2F SERIES LIGHTING
APPLICATION DATA FOR HAZARDOUS LOCATIONS L49
L
VQ1F/VQ2F SERIES THERMAL PERFORMANCE DATA1
CLASS I DIVISION 2 GROUPS A,B,C,D / ZONE 2 GROUPS IIC, IIB, IIA / CLASS II E,F,G / CLASS III
CATALOG
NUMBER*
LAMP
WATTS
AMBIENT
DEGREES C
VQ1F1330 13 (1X13)
VQ1F1830 18 (1X18)
VQ1F26S30 26 (1X26)
VQ1F3230 32 (1X32)
VQ1F4230 42 (1X42)
VQ1F2630 26 (2X13)
VQ1F3630 36 (2X18)
VQ1F5230 52 (2X26)
VQ1F6430 64 (2X32)
VQ1F8430 84 (2X42)
VQ2F1330 13 (1X13)
VQ2F1830 18 (1X18)
VQ2F26S30 26 (1X26)
VQ2F3230 32 (1X32)
VQ2F4230 42 (1X42)
VQ2F2630 26 (2X13)
VQ2F3630 36 (2X18)
VQ2F5230 52 (2X26)
VQ2F6430 64 (2X32)
VQ1F8430 84 (2X42)
40 T3C T3C T6 T6 T3C (EFG) T3C (EFG) 75
55 T3C T3C T6 T6 T3C (EFG) T3C (EFG) 75
40 T3C T3C T6 T6 T3C (EFG) T3C (EFG) 75
55 T3C T3C T6 T6 T3C (EFG) T3C (EFG) 75
40 T3A T3A T6 T6 T3C (EFG) T3C (EFG) 75
55 T3A T3A T6 T6 T3C (EFG) T3C (EFG) 75
40 T3A T3A T6 T6 T3C (EFG) T3C (EFG) 75
55 T3A T3A T6 T6 T3C (EFG) T3C (EFG) 75
40 T3A T3A T6 T6 T3C (EFG) T3C (EFG) 75
55 T3A T3A T6 T6 T3C (EFG) T3C (EFG) 75
40 T3A T3A T6 T6 T3C (EFG) T3C (EFG) 60
55 T3A T3A T5 T5 T3C (EFG) T3C (EFG) 75
40 T3A T3A T6 T6 T3C (EFG) T3C (EFG) 60
55 T3A T3A T6 T6 T3C (EFG) T3C (EFG) 75
40 T3 T2D T6 T5 T3C (EFG) T3C (EFG) 75
55 T2D T2D T4 T4 T3C (EFG) T3C (EFG) 75
40 T3 T2D T6 T5 T3C (EFG) T3C (EFG) 75
55 T2D T2D T4 T4 T3C (EFG) T3C (EFG) 75
40 T2B T2B T4 T4 T3C (EFG) T3C (EFG) 75
55 XXX XXX XXX XXX XXX XXX XXX
40 T3C T3C T6 T6 T4A (EFG) T4A (EFG) 60
55 T3C T3C T6 T6 T4A (EFG) T4A (EFG) 75
40 T3C T3C T6 T6 T4A (EFG) T4A (EFG) 60
55 T3C T3C T6 T6 T4A (EFG) T4A (EFG) 75
40 T3A T3A T6 T6 T4A (EFG) T4A (EFG) 60
55 T3A T3A T6 T6 T4A (EFG) T4A (EFG) 75
40 T3A T3A T6 T6 T4A (EFG) T4A (EFG) 60
55 T3A T3A T6 T6 T4A (EFG) T4A (EFG) 75
40 T3A T3A T6 T6 T4A (EFG) T4A (EFG) 60
55 T3A T3A T6 T6 T4A (EFG) T4A (EFG) 75
40 T3A T3A T6 T6 T4A (EFG) T4A (EFG) 60
55 T3A T3A T6 T6 T4A (EFG) T4A (EFG) 75
40 T3A T3A T6 T6 T4A (EFG) T4A (EFG) 60
55 T3A T3A T6 T6 T4A (EFG) T4A (EFG) 75
40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 60
55 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 60
55 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
40 T2C T2C T6 T6 T4A (EFG) T4A (EFG) 75
55 XXX XXX XXX XXX XXX XXX XXX-
CLASS I DIVISION 2 CLASS I ZONE 2 NR II CLASS II DIVISION 1 (3)
GLOBE OR
REFRACTOR 1
GLOBE +
REFLECTOR
GLOBE OR
REFRACTOR 1
GLOBE +
REFLECTOR
TEMP.
MIN. °C
SUPPLY WIRE
GLOBE OR
REFRACTOR 2
GLOBE +
REFLECTOR
T-CODE & TEMPERATURE RANGE CONVERSION TABLE ˚C
1C1D2 & T-codes for Refractors include VMR “All Glass” and VZ Spin-Top Types. Also applies for VMER40 and
VMEP40 in VQ2F models.
2T-codes for Ex nR Refractors are for VMR “All Glass” Types. Also applies for VMER40 and VMEP40 in VQ2F models.
3Models suitable for Class II Div. 1 are also suitable for Class III.
* VQ1F models use 5-1/2" CertiLite®V VM optics; VQ2F models use 7-3/4" VM optics.
VQ1F/VQ2F SERIES LIGHTING
PHOTOMETRIC DATA
L50
VQ1F 64Watt
Globe Only
VQ1F 64Watt
Globe & Dome Reflector
VQ1F 64Watt
Type V Glass Refractor
Certified Report LSI25349 Certified Report LSI25351 Certified Report LSI25357
C E R T I L I T E®V SERIES HID & INDUCTION LIGHTING
INTRODUCTION L51
L
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option2
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
VM3 VM4
KILLARK®CertiLite®VSeries sets a new standard for industrial
grade HID luminaires. Designed for installations where moisture,
dirt, dust, corrosion and vibration may be present, these fixtures
are suitable for NEMA 3 and 4X areas and where wind, water,
snow or high ambients can be expected. They also can be
used in locations made hazardous by the presence of flamma-
ble vapors and gases or combustible dusts, as defined by the
NEC®. Typical applications include manufacturing sites, chemi-
cal and petrochemical processing facilities, sewage treatment
plants, off-shore and dockside installations, garages and ware-
houses.
Standard Materials:
Ballast tank and splice box – corrosion resistant copper-free alu-
minum alloy with baked powder epoxy/polyester finish, electrosta-
tically applied for complete, uniform corrosion protection.
All external hardware – 316 stainless steel.
Guards – Painted copper-free aluminum alloy or 316SS for 7-3/4"
glass optics and Enclosed Reflectors.
Spin-top Refractor Guards are Plated Steel.
Reflectors – lightweight, corrosion resistant fiberglass reinforced
polyester, or copper-free aluminum.
Additional Features:
Seven mounting splice box types; Pendant, Flex Pendant, Ceiling,
Wall bracket, Cone Top, 25° Angle Stanchion, Straight Stanchion
– in a variety of entry sizes, including M20 for the VMX ceiling style.
Quartz auxiliary, HPS instant restart, Ballast Protectors
Minimum starting temperature: HPS – 40°C; MV, MH & MHP – 30°C
Normally shipped as components for fast delivery, or may be
ordered factory assembled with or without lamps.
Options for fuses and Quick Disconnect
Compliances
UL1598 Standard for luminaires
UL1598A Marine type luminaire
UL-844 Standard for lighting fixtures for hazardous locations
CSA C22.2 no. 137-M1981 electric luminaries for use in haz-
ardous locations
Enclosed and gasketed
NEMA 3, 4X IP66
UL 60079-15 - Electrical apparatus for Explosive Gas
Atmospheres with Type of Protection “n” (Restricted Breathing and
non-sparking).
FEATURES BENEFITS
Swing-Barrel Nut
Patented Tank
Mounting System
• Stainless-to-Stainless securement
• Takes load off during installation
• Uses ordinary tools
• Saves time and labor
Cover a wider range of wattage sizes and
socket types (will include five total) for
maximum user selection flexibility
Sealed Optic Zone 2
AEx nAR Restricted
Breathing (suffix NR)
NO External Seals. Lower T-codes, Suitable
for Class I Div. 2 Classified areas per the
NEC®
All glass refractors Compact (5-1/2" thread size, types I & V)
Standard (7-3/4", thread size,types I, III, V)
Enhances user selection flexibility
New “EZ” mount
adapter
Easier Maintenance, saves labor, move
fixture from the ladder to the workbench
Photo controls -
Class I Div. 2 /
N4X areas
Available as Field or Factory Installed to
save energy when light not required
Earthquake Tab -
Built-in attachment
point for safety cables
Safety: Secures fixture to structure in case
of conduit failure. “3rd hand” acces-
sories for lamp change out
“FULL CUTOFF” &
CUTOFF Optics
For “Dark Sky” Requirements. Helps to min-
imize offending light pollution
VMEP40
“Food Optic”
Expanded Offering
for Food or Grain Handling
Applications to minimize contamination
NEMA Decals Easier Maintenance, Saves labor
“Have the right lamp in hand
before going up the ladder”.
Expanded lamp
types and wattages
Philips®QL Induction type and 600Watt HPS
available for long life or high lumen require-
ments
CertiLite
Software
U
sed to determine number of fixtures
required and their proper layout for various
tasks and applications.
Listed - File E10514 (Hazardous & Marine)
15 17 17P
I III V
VM5
®
Philips®is a registered trademark of Koninklijke Philips Electronics N.V.
12 See Thermal Performance Tables beginning L104.
New ballast tank sizes
Certified - File LR11713
FEATURES-SPECIFICATIONS
VM1 VM2
VM3
5 1/2" Optic
Low Wattage
Mogul Base
CERTILITE®V SERIES LIGHTING
INTRODUCTION
SWING-BARREL NUT
®
VM1
5 1/2" Optic
Reduced Profile
Medium Base
VM2
7 3/4" Optic
Reduced Profile
Medium Base
VM4
7 3/4" Optic
Low Wattage
Mogul Base
VM5
7 3/4" Optic
High Wattage
Mogul Base
The CertiLite®VSwing-Barrel Nut System provides a
Stainless-to-Stainless securement between tank and mounting
box. No more Stainless-to-Aluminum connections or need for
Stainless inserts.
Users can easily lift the tank into place and “take the load off”,
then tighten. Saves time and labor.
Only the patented Swing-Barrel Nut Stainless System can be
tightened with a common screwdriver or nut driver; others are
either stainless-to-aluminum, or require a wrench or special
deep socket.
NOTE: CertiLite®Vseries tanks are backwardly compatible with older CertiLite®
mounts. Simply remove Barrel Nut and thread into old mount.
Or turn the page for more features/comparisons
123
QUICK LOCATOR TABLE
Hang
Fixture Swing into Place Tighten
HPS
MH
MHP
QL
35-150
50-100
200-600
50-100
70-250
400
125-175
125-200
250-400
55
85
165
VM1 & VM2
VM3 & VM4
VM5
VM1 & VM2
VM3 & VM4
VM5
VM1 & VM2
VM3 & VM4
VM5
VM1
VM4
VM5
L58
L67
L80
L62
L71
L84
L62
L75
L86
L91
L91
L91
L93
L100
L104
L114
L57
L66
L79
L90
L97
Lamp Type Wattage Range Luminaire Tank Begins on Page
Accessories
Dimensional Information
Temperature Data
Photometrics
VM1 & VM2 Logic Tree
VM3 & VM4 Logic Tree
VM5 Logic Tree
QL Logic Tree
Cross-reference guide CertiLite®to CertiLite®V
L52
Maintenance personnel are often in
awkward positions when relamping: trying to
simultaneously hold on to a ladder, a globe
and the lamp. Available “3rd Hand” suspen-
sion cables support 5-1/2" VMG17/VMR17x
optics, utilizing the VMAG17 guard. 7-3/4"
VMG25/VMR25x/VMG40 optics utilize the
VMAGxxS guard and VMAGBC bottom clo-
sure. Cables attach to a special “Earthquake
Tab built into the ballast tank housing. See
Suspension Accessories page L96.
CertiLite®Vtanks as standard have a built-in
“Earthquake Tab. The tab is used to hold optic
suspension devices, and can simultaneously
be used to add a safety cable linked to the
building superstructure.
To enable easy and safe removal of CertiLite®Vfixtures for maintenance, install with the
new VMEZA ballast tank to EZ mount adapter.
The complete assembly is removed for maintenance at the workbench.
Large facilities often keep spares so that a “new” fixture is put in at the time one needs
maintenance – thus eliminating the need to set up access equipment multiple times.
®
HAVE THE RIGHT LAMP IN HAND
BEFORE GOING UP THE LADDER.
For Personnel Safety
15 17
YELLOW
150W HPS
RED
175W MH
RED
175W MHP
15
3"
3"
NEMA Decals
for Lamp Type
& Wattage
* “P designates newer Pulse Start Metal Halide lamps:
150, 175, 200, 250, 320, 350 and 400 watt models.
*
17P
Attach to
Building
Structure.
Need a Hand?
CERTILITE®V SERIES LIGHTING
INTRODUCTION L53
EZ MOUNT & LAMP INDENTIFICATION
L
CERTILITE®V SERIES LIGHTING
INTRODUCTION
®
NEW Sealed Optic” construction, option NR. Rated for
Class I, Zone 2 AEx nAnR/Ex nR II Restricted Breathing.
Sealed Entry is no longer required to obtain significantly lower T-codes.
CertiLite®Vluminaires with the NR option
are factory sealed to save installation
time and labor costs.
AEx nAnR/Ex nR II is covered under
NEC®Article 505, and indicates Non-
Arcing and Non-Breathing.
North American Class I Division 2 desig-
nated locations may use properly
marked Zone 2 rated equipment per
NEC Article 501.5.
The CertiLite®VNR option is available
for VMG, VMR, and VMER40 optics, but
not VZRG Type “Spin-top” Refractors.
Permits the use of fewer higher wattage
luminaires for a given application.
No labor intensive conduit seals
or sealed cable glands required
for installation
Factory seal above lamp
chamber restricts air flow,
preventing hazardous vapors
from reaching the lamp. This
allows temperature code
measurement at the globe vs.
the lamp, allowing lower
T-codes for a given lamp size
and type.
150 HPS
400 HPS
175 MH
400 MH
VM3 w/VMG or VMR
VM4 w/VMG or VMR
VM5 w/VMG
VM5 w/VMER40
VM3 w/VMG or VMR
VM4 w/VMG or VMR
VM5 w/VMG40
VM5 w/VMER40
T2B (260°C)
T2B (260°C)
350° C
350° C
T2A (280°C)
T2B (260°C)
325° (300°C)
T2 (300°C)
T4 (135°C)
T4 (135°C)
T3 (200°C)
T3 (200°C)
T3 (200°C)
T4 (135°C)
T3 (200°C)
T3 (200°C)
-125°C
-125°C
-150°C
-150°C
-80°C
-125°C
-100°C
-100°C
Lamp Type
and
Wattage
Examples at 40c ambient.
See thermal performance
charts beginning L84 for
more information
Class I Div. 2/
Zone 2
Globe only
1
Class I Zone 2
AEX nAnR II
2
Reduction
in Applied
T-Code
For Lower T-Codes
See the Benefit!
1Based on Lamp temperature data
2Based on Globe temperature data
L54
CERTILITE®V SERIES LIGHTING
INTRODUCTION L55
CertiLite®VVM4 or VM5 series luminaires with the new
VMEP40 Optic have a strong non-glass polycarbonate
shield protecting food from potential broken glass contam-
ination, as could be the case even with heat-resistant
heavy duty globes.
Unique design incorporates internal glass lens to seal out
dust and vapors from the lamp, with a polycarbonate
shield banded tightly at the bottom.
Copper-free aluminum reflector has anodized finish
for easy cleaning; threaded portion at top is natural
aluminum to prevent paint dust contamination during
maintenance (from attaching/detaching).
Polycarbonate shield is replaceable and must always
be used to maintain ratings. Order part number
VMEP40-LENS.
CertiLite®Vnow offers additional all-glass threaded
refractors, and many are available with a Teflon coating.
Teflon®coating helps to reduce the likelihood of glass
breakage, and if broken, reduces the area of contamination.
Also enhances cleanability.
Teflon®is a registered trademark of Dupont, Inc.
EXPANDED TEFLON®COATED OPTICS
VMG17T
®
Listed and Certified
Class I Div. 2; Class II Div. 1;
N4X
Grain Area
Food Area
VMEP40 Optic
For Food & Grain Safety
and Low Bay Applications
SAFETY COATING
L
CERTILITE®V SERIES LIGHTING
INTRODUCTION
L56
®
For Dark Sky Needs
CertiLiteV
®
KILLARK vs. COMPETITION
Swing-barrel nut (patented)
Stainless-to-Stainless securement
between tank and mounting box.
Can be tightened with a common
screwdriver or nut driver.
Either not stainless, or
require a wrench or
special deep socket.
Earthquake tab
Built in securement location for
safety cables, optic “3rd Hand”
or to building structure.
Maintenance Safety Optic
suspension systems
Suspension safety cable to
building superstructure
“Sealed Optic”
Instead of more costly “Sealed Entry”
Meets AEx nAR Requirements
VMEP40
Food Area Suitable Optic
Dark Sky
Optics Available
316 Stainless Guards
For 7 3/4" All Glass Optics.
Optional Bottom Closure.
Not
Available
Not
Available
Not
Available
Only Glass
Optics Offered
“Sealed Entry” requires extra parts
(conduit seals) and labor to
install, and block pulling of
replacement wiring.
Limited, if any, solutions for light
pollution, a problem in many areas.
“Ordinary” stainless & open bottom type
only. Provides less protection
from bottom impact or corrosion.
COMPETITIVE COMPARISONS
The CertiLite®VVMER40 Enclosed Reflector meets the Full Cuttoff
photometric requirement in many areas, such as observatories, to
minimize offending light pollution. Fits VM4 and VM5 Series tanks.
Use VMDARK1 gasket kit to enable the deep HRD Series Reflectors
to meet the “Full Cutoff requirement over globes on the VM4, or
Cutoff on VM5 Series tanks. See L96 for more information.
L57
CertiL i t e ®VCatalog Number Logic; 35-175 Low Wattage (Medium Base) HID Fixtures
Series Constant
Optic Thread Size
1—5 1/2"
2—7 3/4"
Lamp Type
S—HPS (35, 50, 70, 100, 150)
H—MH (50, 70, 100)
P—MHP (1251, 150, 175)
Voltage @ 60 Hertz
1—120V
0—Quadri-Volt (120, 208, 240, 277)
5—480V
6—Tri - 120, 277, 347 (Canada)
7—220V
8—220/240 50 Hz
Mounting Type
A—Pendant
F—Flexible Pendant
X—Ceiling
B—Wall Bracket
C—Cone Top
E—EZ Mount Adapter2
D—Stanchion 25°
S—Stanchion Straight 90°
N—None (mount ordered
separately)3
Lamp Wattage
03—35W, (HPS)
05—50W, (HPS, MH)
07—70W, (HPS, MH)
10—100W, (HPS, MH)
12—125W, (MHP1)
15—150W, (HPS, MHP)
17—175W, (MHP)
Guard
G—Guard (Globes & Glass
refractors)
N—No Guard8
Options
IR—Instant Restrike - 50-150
HPS
QA—Quartz Auxiliary9
BP—Ballast Protector -
70-150 HPS
F1—Fusing 120V
F2—Fusing 208V
F3—Fusing 240V
F4—Fusing 277V
F5—Fusing 480V
F6—Fusing 347V
F7—Fusing 220V
F8—Fusing 240V 50 Hz
P1—Photocell 120V
P2—Photocell 208-277V
P3—Photocell 347V
Q1—QD Wired to 120V
Q2—QD Wired to 208V
Q3—QD Wired to 240V
Q4—QD Wired to 277V
Q5—QD Wired to 480V
Q6—QD Wired to 347V
Q7—QD 220V
Q8—QD 240V (50Hz)
TBx—Terminal Blocks
x= Voltage Code
AS—Assembled Fixture with
Standard Lamp
AD—Assembled Fixture with
Dual Arc Tube Lamp 70,
100, 150 HPS only
AN—Assembled, no lamp
CP—Component Pack-No
Lamp
CS—Component Pack with
Standard Lamp
Optic
GL—Globe (VM1, VM2)
R1—Type I Glass Refractor (VM1,
VM2)
R3—Type III Glass Refractor (VM2)
R5—Type V Glass Refractor (VM1,
VM2)
ER—Enclosed Reflector (VM2)
EP—Poylcarbonate Shielded
Enclosed Reflector (VM2)
S2—Type II 12" Spin-Top Refractor
(VM14, VM2)
S8—Type V 8" Spin-Top Refractor
(VM1)
S5—Type V 12" Spin-Top Refractor
(VM14, VM2)
P5—Type V 12" Plastic Spin-Top
Refractor (VM1-175W Max.)
FG—Silicone5Coated Globe (VM1,
VM2)
TG—Teflon®6Coated Globe (VM1,
VM2)
T1—Teflon®6Coated Globe Type I
Glass Refractor (VM1, VM2)
T3—Teflon®6Coated Globe Type III
Glass Refractor (VM2)
T5—Teflon®6Coated Globe Type V
Glass Refractor (VM1, VM2)
T2—Teflon®6Coated Type II 12"
Spin-Top Refractor (VM14,
VM2)
T8—Teflon®6Coated Type V 8"
Spin-Top Refractor (VM1)
TV—Teflon®6Coated Type V 12"
Spin-Top Refractor (VM14,
VM2)
Entry (Mounts available)
2—3/4" NPT (A,B,C,X)
3—1" NPT (A,B,C,X)
4—1 1/4" NPT (D,S)
5—1 1/2" NPT (D,S)
6—3/4" NPT 5-Hub (X)
7—1" NPT 5-Hub (X)
8—M20 4-Hub (X)
9—M20 5-Hub (X)
Z—EZ Mount Adapter2
N—None (mount ordered
separately)3
VM 0 0 00 0 0 0 00 0 (NR7) 00
1Special order lamp type/wattage not shown in grids, minimums apply.
2Completes as “EZ”, conduit mounting boxes ordered separately - See L83.
3NN mount ordered separately.
412" Spintops for use with VM3 tanks ship with a Mogul to Mogul socket
extender for enhanced photometrics vs. 7 3/4", which are used on VM5,
but will fit VM4.
5Silicone coated globe for additional impact protection.
6Teflon®is a registered trademark of DuPont, Inc.
Consult factory for available lamp and voltage combinations.
7Restricted Breathing - See L54 for more information.
8Order Guards for Spin-Tops & VMER40 separately.
9QA not suitable for Class I, Div. 2/Zone 2 applications; consult factory
for other hazardous applications.
Fusing not for Marine or Canadian installations.
Photo cells for Class I, Div. 2 only, or C1Z2 nR , not Class II.
Field connection to proper tap in case of Multitap Ballasts.
Not for use with wall or straight (90°) Stanchion.
QD = Quick Disconnect. Allows easy tank removal for maintenance.
Electrician simply unplugs de-energized ballast from supply circuit.
220V 60Hz or 230V 50Hz used with QA-requires VM5 tank.
IR and BP cannot be ordered together.
®
11
12
13
13
14
15
16
11 12
11 12
11 12
14
16
16
14
14
14
14
14
14
V
V
CERTILITE®V SERIES LIGHTING
VM1/VM2 CATALOG ORDERING LOGIC
L
1See hazardous location data pages L104-107 for application suitability
2Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VM1S050A2GLN
3Catalog numbers shown are with 3/4" conduit openings; change “2” to “3” for 1" e.g. VM1S050A3GLG
4Consult catalog logic for other available voltage & lamp combinations
5Add suffix NR for AEx nR Restricted Breathing; see page L54 for more information
CERTILITE®V SERIES LIGHTING
HIGH PRESSURE SODIUM, 35-150W MEDIUM BASE HID
L58
VM 35-150 HIGH PRESSURE SODIUM-PENDANT
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
35 S76 3/4" 120V VM1S031A2GLG VM1S031A2R1G VM1S031A2R5G VM2S031A2GLG VM2S031A2R1G VM2S031A2R5G VM2S031A2S5G
50 S68 3/4" Quad VM1S050A2GLG VM1S050A2R1G VM1S050A2R5G VM2S050A2GLG VM2S050A2R1G VM2S050A2R5G VM2S050A2S5G
Quad VM1S070A2GLG VM1S070A2R1G VM1S070A2R5G VM2S070A2GLG VM2S070A2R1G VM2S070A2R5G VM2S070A2S5G
70 S62 3/4" Tri VM1S076A2GLG VM1S076A2R1G VM1S076A2R5G VM2S076A2GLG VM2S076A2R1G VM2S076A2R5G VM2S076A2S5G
480 VM1S075A2GLG VM1S075A2R1G VM1S075A2R5G VM2S075A2GLG VM2S075A2R1G VM2S075A2R5G VM2S075A2S5G
Quad VM1S100A2GLG VM1S100A2R1G VM1S100A2R5G VM2S100A2GLG VM2S100A2R1G VM2S100A2R5G VM2S100A2S5G
100 S54 3/4" Tri VM1S106A2GLG VM1S106A2R1G VM1S106A2R5G VM2S106A2GLG VM2S106A2R1G VM2S106A2R5G VM2S106A2S5G
480 VM1S105A2GLG VM1S105A2R1G VM1S105A2R5G VM2S105A2GLG VM2S105A2R1G VM2S105A2R5G VM2S105A2S5G
Quad VM1S150A2GLG VM1S150A2R1G VM1S150A2R5G VM2S150A2GLG VM2S150A2R1G VM2S150A2R5G VM2S150A2S5G
150 S55 3/4" Tri VM1S156A2GLG VM1S156A2R1G VM1S156A2R5G VM2S156A2GLG VM2S156A2R1G VM2S156A2R5G VM2S156A2S5G
480 VM1S155A2GLG VM1S155A2R1G VM1S155A2R5G VM2S155A2GLG VM2S155A2R1G VM2S155A2R5G VM2S155A2S5G
VM1
Flexible Pendant
w/5-1/2"
Refractor & Guard
VM1 Pendant
w/5-1/2"
Globe & Guard
VM2 Pendant
w/7-3/4"
Globe & Guard
VM2
Flexible Pendant
w/7-3/4"
Refractor & Guard
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
VM 35-150 HIGH PRESSURE SODIUM-FLEX PENDANT
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
35 S76 3/4" 120V VM1S031F2GLG VM1S031F2R1G VM1S031F2R5G VM2S031F2GLG VM2S031F2R1G VM2S031F2R5G VM2S031F2S5G
50 S68 3/4" Quad VM1S050F2GLG VM1S050F2R1G VM1S050F2R5G VM2S050F2GLG VM2S050F2R1G VM2S050F2R5G VM2S050F2S5G
Quad VM1S070F2GLG VM1S070F2R1G VM1S070F2R5G VM2S070F2GLG VM2S070F2R1G VM2S070F2R5G VM2S070F2S5G
70 S62 3/4" Tri VM1S076F2GLG VM1S076F2R1G VM1S076F2R5G VM2S076F2GLG VM2S076F2R1G VM2S076F2R5G VM2S076F2S5G
480 VM1S075F2GLG VM1S075F2R1G VM1S075F2R5G VM2S075F2GLG VM2S075F2R1G VM2S075F2R5G VM2S075F2S5G
Quad VM1S100F2GLG VM1S100F2R1G VM1S100F2R5G VM2S100F2GLG VM2S100F2R1G VM2S100F2R5G VM2S100F2S5G
100 S54 3/4" Tri VM1S106F2GLG VM1S106F2R1G VM1S106F2R5G VM2S106F2GLG VM2S106F2R1G VM2S106F2R5G VM2S106F2S5G
480 VM1S105F2GLG VM1S105F2R1G VM1S105F2R5G VM2S105F2GLG VM2S105F2R1G VM2S105F2R5G VM2S105F2S5G
Quad VM1S150F2GLG VM1S150F2R1G VM1S150F2R5G VM2S150F2GLG VM2S150F2R1G VM2S150F2R5G VM2S150F2S5G
150 S55 3/4" Tri VM1S156F2GLG VM1S156F2R1G VM1S156F2R5G VM2S156F2GLG VM2S156F2R1G VM2S156F2R5G VM2S156F2S5G
480 VM1S155F2GLG VM1S155F2R1G VM1S155F2R5G VM2S155F2GLG VM2S155F2R1G VM2S155F2R5G VM2S155F2S5G
1See hazardous location data pages L104-107 for application suitability
2Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VM1S050X2GLN
3Catalog numbers shown are with 3/4" conduit openings; change “2” to “3” for 1" e.g. VM1S050X3GLG
4Consult catalog logic for other available voltage & lamp combinations
5Add suffix NR for AEx nR Restricted Breathing; see page L54 for more information
CERTILITE®V SERIES LIGHTING
HIGH PRESSURE SODIUM, 35-150W MEDIUM BASE HID L59
L
VM 35-150 HIGH PRESSURE SODIUM-CEILING
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
35 S76 3/4" 120V VM1S031X2GLG VM1S031X2R1G VM1S031X2R5G VM2S031X2GLG VM2S031X2R1G VM2S031X2R5G VM2S031X2S5G
50 S68 3/4" Quad VM1S050X2GLG VM1S050X2R1G VM1S050X2R5G VM2S050X2GLG VM2S050X2R1G VM2S050X2R5G VM2S050X2S5G
Quad VM1S070X2GLG VM1S070X2R1G VM1S070X2R5G VM2S070X2GLG VM2S070X2R1G VM2S070X2R5G VM2S070X2S5G
70 S62 3/4" Tri VM1S076X2GLG VM1S076X2R1G VM1S076X2R5G VM2S076X2GLG VM2S076X2R1G VM2S076X2R5G VM2S076X2S5G
480 VM1S075X2GLG VM1S075X2R1G VM1S075X2R5G VM2S075X2GLG VM2S075X2R1G VM2S075X2R5G VM2S075X2S5G
Quad VM1S100X2GLG VM1S100X2R1G VM1S100X2R5G VM2S100X2GLG VM2S100X2R1G VM2S100X2R5G VM2S100X2S5G
100 S54 3/4" Tri VM1S106X2GLG VM1S106X2R1G VM1S106X2R5G VM2S106X2GLG VM2S106X2R1G VM2S106X2R5G VM2S106X2S5G
480 VM1S105X2GLG VM1S105X2R1G VM1S105X2R5G VM2S105X2GLG VM2S105X2R1G VM2S105X2R5G VM2S105X2S5G
Quad VM1S150X2GLG VM1S150X2R1G VM1S150X2R5G VM2S150X2GLG VM2S150X2R1G VM2S150X2R5G VM2S150X2S5G
150 S55 3/4" Tri VM1S156X2GLG VM1S156X2R1G VM1S156X2R5G VM2S156X2GLG VM2S156X2R1G VM2S156X2R5G VM2S156X2S5G
480 VM1S155X2GLG VM1S155X2R1G VM1S155X2R5G VM2S155X2GLG VM2S155X2R1G VM2S155X2R5G VM2S155X2S5G
VM1 Wall
w/5-1/2"
Refractor & Guard
VM1 Ceiling
w/5-1/2"
Globe & Guard
VM2 Ceiling
w/7-3/4"
Globe & Guard
VM2 Wall
w/7-3/4"
Refractor & Guard
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
VM 35-150 HIGH PRESSURE SODIUM-WALL
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
35 S76 3/4" 120V VM1S031B2GLG VM1S031B2R1G VM1S031B2R5G VM2S031B2GLG VM2S031B2R1G VM2S031B2R5G VM2S031B2S5G
50 S68 3/4" Quad VM1S050B2GLG VM1S050B2R1G VM1S050B2R5G VM2S050B2GLG VM2S050B2R1G VM2S050B2R5G VM2S050B2S5G
Quad VM1S070B2GLG VM1S070B2R1G VM1S070B2R5G VM2S070B2GLG VM2S070B2R1G VM2S070B2R5G VM2S070B2S5G
70 S62 3/4" Tri VM1S076B2GLG VM1S076B2R1G VM1S076B2R5G VM2S076B2GLG VM2S076B2R1G VM2S076B2R5G VM2S076B2S5G
480 VM1S075B2GLG VM1S075B2R1G VM1S075B2R5G VM2S075B2GLG VM2S075B2R1G VM2S075B2R5G VM2S075B2S5G
Quad VM1S100B2GLG VM1S100B2R1G VM1S100B2R5G VM2S100B2GLG VM2S100B2R1G VM2S100B2R5G VM2S100B2S5G
100 S54 3/4" Tri VM1S106B2GLG VM1S106B2R1G VM1S106B2R5G VM2S106B2GLG VM2S106B2R1G VM2S106B2R5G VM2S106B2S5G
480 VM1S105B2GLG VM1S105B2R1G VM1S105B2R5G VM2S105B2GLG VM2S105B2R1G VM2S105B2R5G VM2S105B2S5G
Quad VM1S150B2GLG VM1S150B2R1G VM1S150B2R5G VM2S150B2GLG VM2S150B2R1G VM2S150B2R5G VM2S150B2S5G
150 S55 3/4" Tri VM1S156B2GLG VM1S156B2R1G VM1S156B2R5G VM2S156B2GLG VM2S156B2R1G VM2S156B2R5G VM2S156B2S5G
480 VM1S155B2GLG VM1S155B2R1G VM1S155B2R5G VM2S155B2GLG VM2S155B2R1G VM2S155B2R5G VM2S155B2S5G
1See hazardous location data pages L104-107 for application suitability.
2Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VM1S050C2GLN.
3Catalog numbers shown are with 3/4" conduit openings; change “2” to “3” for 1" e.g. VM1S050C3GLG.
4Consult catalog logic for other available voltage & lamp combinations.
5Add suffix NR for AEx nR Restricted Breathing; see page L54 for more information.
6VMEZA tank adapters UL “classified” as an assembly for use between VM tanks and EZ mounts. Order EZ mounts separately. See page L83.
CERTILITE®V SERIES LIGHTING
HIGH PRESSURE SODIUM, 35-150W MEDIUM BASE HID
L60
VM1 EZ Adapter
w/5-1/2"
Refractor & Guard
VM1 Cone
w/5-1/2"
Globe & Guard
VM2 Cone
w/7-3/4"
Globe & Guard
VM2 EZ Adapter
w/7-3/4"
Refractor & Guard
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
VM 35-150 HIGH PRESSURE SODIUM-CONE
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
35 S76 3/4" 120V VM1S031C2GLG VM1S031C2R1G VM1S031C2R5G VM2S031C2GLG VM2S031C2R1G VM2S031C2R5G VM2S031C2S5G
50 S68 3/4" Quad VM1S050C2GLG VM1S050C2R1G VM1S050C2R5G VM2S050C2GLG VM2S050C2R1G VM2S050C2R5G VM2S050C2S5G
Quad VM1S070C2GLG VM1S070C2R1G VM1S070C2R5G VM2S070C2GLG VM2S070C2R1G VM2S070C2R5G VM2S070C2S5G
70 S62 3/4" Tri VM1S076C2GLG VM1S076C2R1G VM1S076C2R5G VM2S076C2GLG VM2S076C2R1G VM2S076C2R5G VM2S076C2S5G
480 VM1S075C2GLG VM1S075C2R1G VM1S075C2R5G VM2S075C2GLG VM2S075C2R1G VM2S075C2R5G VM2S075C2S5G
Quad VM1S100C2GLG VM1S100C2R1G VM1S100C2R5G VM2S100C2GLG VM2S100C2R1G VM2S100C2R5G VM2S100C2S5G
100 S54 3/4" Tri VM1S106C2GLG VM1S106C2R1G VM1S106C2R5G VM2S106C2GLG VM2S106C2R1G VM2S106C2R5G VM2S106C2S5G
480 VM1S105C2GLG VM1S105C2R1G VM1S105C2R5G VM2S105C2GLG VM2S105C2R1G VM2S105C2R5G VM2S105C2S5G
Quad VM1S150C2GLG VM1S150C2R1G VM1S150C2R5G VM2S150C2GLG VM2S150C2R1G VM2S150C2R5G VM2S150C2S5G
150 S55 3/4" Tri VM1S156C2GLG VM1S156C2R1G VM1S156C2R5G VM2S156C2GLG VM2S156C2R1G VM2S156C2R5G VM2S156C2S5G
480 VM1S155C2GLG VM1S155C2R1G VM1S155C2R5G VM2S155C2GLG VM2S155C2R1G VM2S155C2R5G VM2S155C2S5G
VM 35-150 HIGH PRESSURE SODIUM-EZ ADAPTER6
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
35 S76 6120V VM1S031EZGLG VM1S031EZR1G VM1S031EZR5G VM2S031EZGLG VM2S031EZR1G VM2S031EZR5G VM2S031EZS5G
50 S68 6Quad VM1S050EZGLG VM1S050EZR1G VM1S050EZR5G VM2S050EZGLG VM2S050EZR1G VM2S050EZR5G VM2S050EZS5G
Quad VM1S070EZGLG VM1S070EZR1G VM1S070EZR5G VM2S070EZGLG VM2S070EZR1G VM2S070EZR5G VM2S070EZS5G
70 S62 6Tri VM1S076EZGLG VM1S076EZR1G VM1S076EZR5G VM2S076EZGLG VM2S076EZR1G VM2S076EZR5G VM2S076EZS5G
480 VM1S075EZGLG VM1S075EZR1G VM1S075EZR5G VM2S075EZGLG VM2S075EZR1G VM2S075EZR5G VM2S075EZS5G
Quad VM1S100EZGLG VM1S100EZR1G VM1S100EZR5G VM2S100EZGLG VM2S100EZR1G VM2S100EZR5G VM2S100EZS5G
100 S54 6Tri VM1S106EZGLG VM1S106EZR1G VM1S106EZR5G VM2S106EZGLG VM2S106EZR1G VM2S106EZR5G VM2S106EZS5G
480 VM1S105EZGLG VM1S105EZR1G VM1S105EZR5G VM2S105EZGLG VM2S105EZR1G VM2S105EZR5G VM2S105EZS5G
Quad VM1S150EZGLG VM1S150EZR1G VM1S150EZR5G VM2S150EZGLG VM2S150EZR1G VM2S150EZR5G VM2S150EZS5G
150 S55 6Tri VM1S156EZGLG VM1S156EZR1G VM1S156EZR5G VM2S156EZGLG VM2S156EZR1G VM2S156EZR5G VM2S156EZS5G
480 VM1S155EZGLG VM1S155EZR1G VM1S155EZR5G VM2S155EZGLG VM2S155EZR1G VM2S155EZR5G VM2S155EZS5G
1See hazardous location data pages L104-107 for application suitability.
2Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VM1S050D5GLN.
3Catalog numbers shown are with 1-1/2" conduit openings; change “5” to “4” for 1-1/4" e.g. VM1S050D4GLG.
4Consult catalog logic for other available voltage & lamp combinations.
5Add suffix NR for AEx nR Restricted Breathing; see page L54 for more information.
CERTILITE®V SERIES LIGHTING
HIGH PRESSURE SODIUM, 35-150W MEDIUM BASE HID L61
L
VM1 Stanchion
Straight
w/5-1/2"
Refractor & Guard
VM1 Stanchion 25°
w/5-1/2"
Globe & Guard
VM2 Stanchion 25°
w/7-3/4"
Globe & Guard
VM2 Stanchion
Straight
w/7-3/4"
Refractor & Guard
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
VM 35-150 HIGH PRESSURE SODIUM - STANCHION 25° ANGLE
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
35 S76 1-1/2" 120V VM1S031D5GLG VM1S031D5R1G VM1S031D5R5G VM2S031D5GLG VM2S031D5R1G VM2S031D5R5G VM2S031D5S5G
50 S68 1-1/2" Quad VM1S050D5GLG VM1S050D5R1G VM1S050D5R5G VM2S050D5GLG VM2S050D5R1G VM2S050D5R5G VM2S050D5S5G
Quad VM1S070D5GLG VM1S070D5R1G VM1S070D5R5G VM2S070D5GLG VM2S070D5R1G VM2S070D5R5G VM2S070D5S5G
70 S62 1-1/2" Tri VM1S076D5GLG VM1S076D5R1G VM1S076D5R5G VM2S076D5GLG VM2S076D5R1G VM2S076D5R5G VM2S076D5S5G
480 VM1S075D5GLG VM1S075D5R1G VM1S075D5R5G VM2S075D5GLG VM2S075D5R1G VM2S075D5R5G VM2S075D5S5G
Quad VM1S100D5GLG VM1S100D5R1G VM1S100D5R5G VM2S100D5GLG VM2S100D5R1G VM2S100D5R5G VM2S100D5S5G
100 S54 1-1/2" Tri VM1S106D5GLG VM1S106D5R1G VM1S106D5R5G VM2S106D5GLG VM2S106D5R1G VM2S106D5R5G VM2S106D5S5G
480 VM1S105D5GLG VM1S105D5R1G VM1S105D5R5G VM2S105D5GLG VM2S105D5R1G VM2S105D5R5G VM2S105D5S5G
Quad VM1S150D5GLG VM1S150D5R1G VM1S150D5R5G VM2S150D5GLG VM2S150D5R1G VM2S150D5R5G VM2S150D5S5G
150 S55 1-1/2" Tri VM1S156D5GLG VM1S156D5R1G VM1S156D5R5G VM2S156D5GLG VM2S156D5R1G VM2S156D5R5G VM2S156D5S5G
480 VM1S155D5GLG VM1S155D5R1G VM1S155D5R5G VM2S155D5GLG VM2S155D5R1G VM2S155D5R5G VM2S155D5S5G
VM 35-150 HIGH PRESSURE SODIUM - STANCHION STRAIGHT
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
35 S76 1-1/2" 120V VM1S031S5GLG VM1S031S5R1G VM1S031S5R5G VM2S031S5GLG VM2S031S5R1G VM2S031S5R5G VM2S031S5S5G
50 S68 1-1/2" Quad VM1S050S5GLG VM1S050S5R1G VM1S050S5R5G VM2S050S5GLG VM2S050S5R1G VM2S050S5R5G VM2S050S5S5G
Quad VM1S070S5GLG VM1S070S5R1G VM1S070S5R5G VM2S070S5GLG VM2S070S5R1G VM2S070S5R5G VM2S070S5S5G
70 S62 1-1/2" Tri VM1S076S5GLG VM1S076S5R1G VM1S076S5R5G VM2S076S5GLG VM2S076S5R1G VM2S076S5R5G VM2S076S5S5G
480 VM1S075S5GLG VM1S075S5R1G VM1S075S5R5G VM2S075S5GLG VM2S075S5R1G VM2S075S5R5G VM2S075S5S5G
Quad VM1S100S5GLG VM1S100S5R1G VM1S100S5R5G VM2S100S5GLG VM2S100S5R1G VM2S100S5R5G VM2S100S5S5G
100 S54 1-1/2" Tri VM1S106S5GLG VM1S106S5R1G VM1S106S5R5G VM2S106S5GLG VM2S106S5R1G VM2S106S5R5G VM2S106S5S5G
480 VM1S105S5GLG VM1S105S5R1G VM1S105S5R5G VM2S105S5GLG VM2S105S5R1G VM2S105S5R5G VM2S105S5S5G
Quad VM1S150S5GLG VM1S150S5R1G VM1S150S5R5G VM2S150S5GLG VM2S150S5R1G VM2S150S5R5G VM2S150S5S5G
150 S55 1-1/2" Tri VM1S156S5GLG VM1S156S5R1G VM1S156S5R5G VM2S156S5GLG VM2S156S5R1G VM2S156S5R5G VM2S156S5S5G
480 VM1S155S5GLG VM1S155S5R1G VM1S155S5R5G VM2S155S5GLG VM2S155S5R1G VM2S155S5R5G VM2S155S5S5G
1See hazardous location data pages L104-107 for application suitability.
2Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VM1H050A2GLN.
3Catalog numbers shown are with 3/4" conduit openings; change “2” to “3” for 1" e.g. VM1H050A3GLG.
4Consult catalog logic for other available voltage & lamp combinations.
5Add suffix NR for AEx nR Restricted Breathing; see page L54 for more information.
** 50, 70, & 100 Watt “Traditional Metal Hallide” ballasts include a Pulse Ignitor, as do 150 & 175W Metal Halide Pulse models.
CERTILITE®V SERIES LIGHTING
METAL HALIDE/METAL HALIDE PULSE, 50-175W MEDIUM BASE HID
L62
VM1 Flexible Pendant
w/5-1/2"
Refractor & Guard
VM1 Pendant
w/5-1/2"
Globe & Guard
VM2 Pendant
w/7-3/4"
Globe & Guard
VM2 Flexible Pendant
w/7-3/4"
Refractor & Guard
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
VM 50-175 METAL HALIDE (PULSE**) - PENDANT
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
50 M110 3/4" Quad VM1H050A2GLG VM1H050A2R1G VM1H050A2R5G VM2H050A2GLG VM2H050A2R1G VM2H050A2R5G VM2H050A2S5G
Tri VM1H056A2GLG VM1H056A2R1G VM1H056A2R5G VM2H056A2GLG VM2H056A2R1G VM2H056A2R5G VM2H056A2S5G
Quad VM1H070A2GLG VM1H070A2R1G VM1H070A2R5G VM2H070A2GLG VM2H070A2R1G VM2H070A2R5G VM2H070A2S5G
70 M98 3/4" Tri VM1H076A2GLG VM1H076A2R1G VM1H076A2R5G VM2H076A2GLG VM2H076A2R1G VM2H076A2R5G VM2H076A2S5G
480 VM1H075A2GLG VM1H075A2R1G VM1H075A2R5G VM2H075A2GLG VM2H075A2R1G VM2H075A2R5G VM2H075A2S5G
Quad VM1H100A2GLG VM1H100A2R1G VM1H100A2R5G VM2H100A2GLG VM2H100A2R1G VM2H100A2R5G VM2H100A2S5G
100 M90 3/4" Tri VM1H106A2GLG VM1H106A2R1G VM1H106A2R5G VM2H106A2GLG VM2H106A2R1G VM2H106A2R5G VM2H106A2S5G
480 VM1H105A2GLG VM1H105A2R1G VM1H105A2R5G VM2H105A2GLG VM2H105A2R1G VM2H105A2R5G VM2H105A2S5G
M102 Quad VM1P150A2GLG VM1P150A2R1G VM1P150A2R5G VM2P150A2GLG VM2P150A2R1G VM2P150A2R5G VM2P150A2S5G
150 3/4" Tri VM1P156A2GLG VM1P156A2R1G VM1P156A2R5G VM2P156A2GLG VM2P156A2R1G VM2P156A2R5G VM2P156A2S5G
M142 480 VM1P155A2GLG VM1P155A2R1G VM1P155A2R5G VM2P155A2GLG VM2P155A2R1G VM2P155A2R5G VM2P155A2S5G
M137 Quad VM1P170A2GLG VM1P170A2R1G VM1P170A2R5G VM2P170A2GLG VM2P170A2R1G VM2P170A2R5G VM2P170A2S5G
175 3/4" Tri VM1P176A2GLG VM1P176A2R1G VM1P176A2R5G VM2P176A2GLG VM2P176A2R1G VM2P176A2R5G VM2P176A2S5G
M152 480 VM1P175A2GLG VM1P175A2R1G VM1P175A2R5G VM2P175A2GLG VM2P175A2R1G VM2P175A2R5G VM2P175A2S5G
VM 50-175 METAL HALIDE (PULSE**) - FLEX PENDANT
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
50 M110 3/4" Quad VM1H050F2GLG VM1H050F2R1G VM1H050F2R5G VM2H050F2GLG VM2H050F2R1G VM2H050F2R5G VM2H050F2S5G
Tri VM1H056F2GLG VM1H056F2R1G VM1H056F2R5G VM2H056F2GLG VM2H056F2R1G VM2H056F2R5G VM2H056F2S5G
Quad VM1H070F2GLG VM1H070F2R1G VM1H070F2R5G VM2H070F2GLG VM2H070F2R1G VM2H070F2R5G VM2H070F2S5G
70 M98 3/4" Tri VM1H076F2GLG VM1H076F2R1G VM1H076F2R5G VM2H076F2GLG VM2H076F2R1G VM2H076F2R5G VM2H076F2S5G
480 VM1H075F2GLG VM1H075F2R1G VM1H075F2R5G VM2H075F2GLG VM2H075F2R1G VM2H075F2R5G VM2H075F2S5G
Quad VM1H100F2GLG VM1H100F2R1G VM1H100F2R5G VM2H100F2GLG VM2H100F2R1G VM2H100F2R5G VM2H100F2S5G
100 M90 3/4" Tri VM1H106F2GLG VM1H106F2R1G VM1H106F2R5G VM2H106F2GLG VM2H106F2R1G VM2H106F2R5G VM2H106F2S5G
480 VM1H105F2GLG VM1H105F2R1G VM1H105F2R5G VM2H105F2GLG VM2H105F2R1G VM2H105F2R5G VM2H105F2S5G
M102 Quad VM1P150F2GLG VM1P150F2R1G VM1P150F2R5G VM2P150F2GLG VM2P150F2R1G VM2P150F2R5G VM2P150F2S5G
150 3/4" Tri VM1P156F2GLG VM1P156F2R1G VM1P156F2R5G VM2P156F2GLG VM2P156F2R1G VM2P156F2R5G VM2P156F2S5G
M142 480 VM1P155F2GLG VM1P155F2R1G VM1P155F2R5G VM2P155F2GLG VM2P155F2R1G VM2P155F2R5G VM2P155F2S5G
M137 Quad VM1P170F2GLG VM1P170F2R1G VM1P170F2R5G VM2P170F2GLG VM2P170F2R1G VM2P170F2R5G VM2P170F2S5G
175 3/4" Tri VM1P176F2GLG VM1P176F2R1G VM1P176F2R5G VM2P176F2GLG VM2P176F2R1G VM2P176F2R5G VM2P176F2S5G
M152 480 VM1P175F2GLG VM1P175F2R1G VM1P175F2R5G VM2P175F2GLG VM2P175F2R1G VM2P175F2R5G VM2P175F2S5G
CERTILITE®V SERIES LIGHTING
METAL HALIDE/METAL HALIDE PULSE, 50-175W MEDIUM BASE HID L63
L
1See hazardous location data pages L104-107 for application suitability.
2Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VM1H050X2GLN.
3Catalog numbers shown are with 3/4" conduit openings; change “2” to “3” for 1" e.g. VM1H050X3GLG.
4Consult catalog logic for other available voltage & lamp combinations.
5Add suffix NR for AEx nR Restricted Breathing; see page L54 for more information.
** 50, 70, & 100 Watt “Traditional Metal Hallide” ballasts include a Pulse Ignitor, as do 150 & 175W Metal Halide Pulse models.
VM1 Wall
w/5-1/2"
Refractor & Guard
VM1 Ceiling
w/5-1/2"
Globe & Guard
VM2 Ceiling
w/7-3/4"
Globe & Guard
VM2 Wall
w/7-3/4"
Refractor & Guard
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
VM 50-175 METAL HALIDE (PULSE**) - CEILING
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
50 M110 3/4" Quad VM1H050X2GLG VM1H050X2R1G VM1H050X2R5G VM2H050X2GLG VM2H050X2R1G VM2H050X2R5G VM2H050X2S5G
Tri VM1H056X2GLG VM1H056X2R1G VM1H056X2R5G VM2H056X2GLG VM2H056X2R1G VM2H056X2R5G VM2H056X2S5G
Quad VM1H070X2GLG VM1H070X2R1G VM1H070X2R5G VM2H070X2GLG VM2H070X2R1G VM2H070X2R5G VM2H070X2S5G
70 M98 3/4" Tri VM1H076X2GLG VM1H076X2R1G VM1H076X2R5G VM2H076X2GLG VM2H076X2R1G VM2H076X2R5G VM2H076X2S5G
480 VM1H075X2GLG VM1H075X2R1G VM1H075X2R5G VM2H075X2GLG VM2H075X2R1G VM2H075X2R5G VM2H075X2S5G
Quad VM1H100X2GLG VM1H100X2R1G VM1H100X2R5G VM2H100X2GLG VM2H100X2R1G VM2H100X2R5G VM2H100X2S5G
100 M90 3/4" Tri VM1H106X2GLG VM1H106X2R1G VM1H106X2R5G VM2H106X2GLG VM2H106X2R1G VM2H106X2R5G VM2H106X2S5G
480 VM1H105X2GLG VM1H105X2R1G VM1H105X2R5G VM2H105X2GLG VM2H105X2R1G VM2H105X2R5G VM2H105X2S5G
M102 Quad VM1P150X2GLG VM1P150X2R1G VM1P150X2R5G VM2P150X2GLG VM2P150X2R1G VM2P150X2R5G VM2P150X2S5G
150 3/4" Tri VM1P156X2GLG VM1P156X2R1G VM1P156X2R5G VM2P156X2GLG VM2P156X2R1G VM2P156X2R5G VM2P156X2S5G
M142 480 VM1P155X2GLG VM1P155X2R1G VM1P155X2R5G VM2P155X2GLG VM2P155X2R1G VM2P155X2R5G VM2P155X2S5G
M137 Quad VM1P170X2GLG VM1P170X2R1G VM1P170X2R5G VM2P170X2GLG VM2P170X2R1G VM2P170X2R5G VM2P170X2S5G
175 3/4" Tri VM1P176X2GLG VM1P176X2R1G VM1P176X2R5G VM2P176X2GLG VM2P176X2R1G VM2P176X2R5G VM2P176X2S5G
M152 480 VM1P175X2GLG VM1P175X2R1G VM1P175X2R5G VM2P175X2GLG VM2P175X2R1G VM2P175X2R5G VM2P175X2S5G
VM 50-175 METAL HALIDE (PULSE**) - WALL
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
50 M110 3/4" Quad VM1H050B2GLG VM1H050B2R1G VM1H050B2R5G VM2H050B2GLG VM2H050B2R1G VM2H050B2R5G VM2H050B2S5G
Tri VM1H056B2GLG VM1H056B2R1G VM1H056B2R5G VM2H056B2GLG VM2H056B2R1G VM2H056B2R5G VM2H056B2S5G
Quad VM1H070B2GLG VM1H070B2R1G VM1H070B2R5G VM2H070B2GLG VM2H070B2R1G VM2H070B2R5G VM2H070B2S5G
70 M98 3/4" Tri VM1H076B2GLG VM1H076B2R1G VM1H076B2R5G VM2H076B2GLG VM2H076B2R1G VM2H076B2R5G VM2H076B2S5G
480 VM1H075B2GLG VM1H075B2R1G VM1H075B2R5G VM2H075B2GLG VM2H075B2R1G VM2H075B2R5G VM2H075B2S5G
Quad VM1H100B2GLG VM1H100B2R1G VM1H100B2R5G VM2H100B2GLG VM2H100B2R1G VM2H100B2R5G VM2H100B2S5G
100 M90 3/4" Tri VM1H106B2GLG VM1H106B2R1G VM1H106B2R5G VM2H106B2GLG VM2H106B2R1G VM2H106B2R5G VM2H106B2S5G
480 VM1H105B2GLG VM1H105B2R1G VM1H105B2R5G VM2H105B2GLG VM2H105B2R1G VM2H105B2R5G VM2H105B2S5G
M102 Quad VM1P150B2GLG VM1P150B2R1G VM1P150B2R5G VM2P150B2GLG VM2P150B2R1G VM2P150B2R5G VM2P150B2S5G
150 3/4" Tri VM1P156B2GLG VM1P156B2R1G VM1P156B2R5G VM2P156B2GLG VM2P156B2R1G VM2P156B2R5G VM2P156B2S5G
M142 480 VM1P155B2GLG VM1P155B2R1G VM1P155B2R5G VM2P155B2GLG VM2P155B2R1G VM2P155B2R5G VM2P155B2S5G
M137 Quad VM1P170B2GLG VM1P170B2R1G VM1P170B2R5G VM2P170B2GLG VM2P170B2R1G VM2P170B2R5G VM2P170B2S5G
175 3/4" Tri VM1P176B2GLG VM1P176B2R1G VM1P176B2R5G VM2P176B2GLG VM2P176B2R1G VM2P176B2R5G VM2P176B2S5G
M152 480 VM1P175B2GLG VM1P175B2R1G VM1P175B2R5G VM2P175B2GLG VM2P175B2R1G VM2P175B2R5G VM2P175B2S5G
CERTILITE®V SERIES LIGHTING
METAL HALIDE/METAL HALIDE PULSE, 50-175W MEDIUM BASE HID
L64
1See hazardous location data pages L104-107 for application suitability.
2Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VM1H050C2GLN.
3Catalog numbers shown are with 3/4" conduit openings; change “2” to “3” for 1" e.g. VM1H050C3GLG.
4Consult catalog logic for other available voltage & lamp combinations.
5Add suffix NR for AEx nR Restricted Breathing; see page L54 for more information.
** 50, 70, & 100 Watt “Traditional Metal Hallide” ballasts include a Pulse Ignitor, as do 150 & 175W Metal Halide Pulse models.
VM1 EZ Adapter
w/5-1/2"
Refractor & Guard
VM1 Cone
w/5-1/2"
Globe & Guard
VM2 Cone
w/7-3/4"
Globe & Guard
VM2 EZ Adapter
w/7-3/4"
Refractor & Guard
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
VM 50-175 METAL HALIDE (PULSE**) - CONE
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
50 M110 3/4" Quad VM1H050C2GLG VM1H050C2R1G VM1H050C2R5G VM2H050C2GLG VM2H050C2R1G VM2H050C2R5G VM2H050C2S5G
Tri VM1H056C2GLG VM1H056C2R1G VM1H056C2R5G VM2H056C2GLG VM2H056C2R1G VM2H056C2R5G VM2H056C2S5G
Quad VM1H070C2GLG VM1H070C2R1G VM1H070C2R5G VM2H070C2GLG VM2H070C2R1G VM2H070C2R5G VM2H070C2S5G
70 M98 3/4" Tri VM1H076C2GLG VM1H076C2R1G VM1H076C2R5G VM2H076C2GLG VM2H076C2R1G VM2H076C2R5G VM2H076C2S5G
480 VM1H075C2GLG VM1H075C2R1G VM1H075C2R5G VM2H075C2GLG VM2H075C2R1G VM2H075C2R5G VM2H075C2S5G
Quad VM1H100C2GLG VM1H100C2R1G VM1H100C2R5G VM2H100C2GLG VM2H100C2R1G VM2H100C2R5G VM2H100C2S5G
100 M90 3/4" Tri VM1H106C2GLG VM1H106C2R1G VM1H106C2R5G VM2H106C2GLG VM2H106C2R1G VM2H106C2R5G VM2H106C2S5G
480 VM1H105C2GLG VM1H105C2R1G VM1H105C2R5G VM2H105C2GLG VM2H105C2R1G VM2H105C2R5G VM2H105C2S5G
M102 Quad VM1P150C2GLG VM1P150C2R1G VM1P150C2R5G VM2P150C2GLG VM2P150C2R1G VM2P150C2R5G VM2P150C2S5G
150 3/4" Tri VM1P156C2GLG VM1P156C2R1G VM1P156C2R5G VM2P156C2GLG VM2P156C2R1G VM2P156C2R5G VM2P156C2S5G
M142 480 VM1P155C2GLG VM1P155C2R1G VM1P155C2R5G VM2P155C2GLG VM2P155C2R1G VM2P155C2R5G VM2P155C2S5G
M137 Quad VM1P170C2GLG VM1P170C2R1G VM1P170C2R5G VM2P170C2GLG VM2P170C2R1G VM2P170C2R5G VM2P170C2S5G
175 3/4" Tri VM1P176C2GLG VM1P176C2R1G VM1P176C2R5G VM2P176C2GLG VM2P176C2R1G VM2P176C2R5G VM2P176C2S5G
M152 480 VM1P175C2GLG VM1P175C2R1G VM1P175C2R5G VM2P175C2GLG VM2P175C2R1G VM2P175C2R5G VM2P175C2S5G
VM 50-175 METAL HALIDE (PULSE**) - EZ ADAPTER6
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
50 M110 6Quad VM1H050EZGLG VM1H050EZR1G VM1H050EZR5G VM2H050EZGLG VM2H050EZR1G VM2H050EZR5G VM2H050EZS5G
Tri VM1H056EZGLG VM1H056EZR1G VM1H056EZR5G VM2H056EZGLG VM2H056EZR1G VM2H056EZR5G VM2H056EZS5G
Quad VM1H070EZGLG VM1H070EZR1G VM1H070EZR5G VM2H070EZGLG VM2H070EZR1G VM2H070EZR5G VM2H070EZS5G
70 M98 6Tri VM1H076EZGLG VM1H076EZR1G VM1H076EZR5G VM2H076EZGLG VM2H076EZR1G VM2H076EZR5G VM2H076EZS5G
480 VM1H075EZGLG VM1H075EZR1G VM1H075EZR5G VM2H075EZGLG VM2H075EZR1G VM2H075EZR5G VM2H075EZS5G
Quad VM1H100EZGLG VM1H100EZR1G VM1H100EZR5G VM2H100EZGLG VM2H100EZR1G VM2H100EZR5G VM2H100EZS5G
100 M90 6Tri VM1H106EZGLG VM1H106EZR1G VM1H106EZR5G VM2H106EZGLG VM2H106EZR1G VM2H106EZR5G VM2H106EZS5G
480 VM1H105EZGLG VM1H105EZR1G VM1H105EZR5G VM2H105EZGLG VM2H105EZR1G VM2H105EZR5G VM2H105EZS5G
M102 Quad VM1P150EZGLG VM1P150EZR1G VM1P150EZR5G VM2P150EZGLG VM2P150EZR1G VM2P150EZR5G VM2P150EZS5G
150 6Tri VM1P156EZGLG VM1P156EZR1G VM1P156EZR5G VM2P156EZGLG VM2P156EZR1G VM2P156EZR5G VM2P156EZS5G
M142 480 VM1P155EZGLG VM1P155EZR1G VM1P155EZR5G VM2P155EZGLG VM2P155EZR1G VM2P155EZR5G VM2P155EZS5G
M137 Quad VM1P170EZGLG VM1P170EZR1G VM1P170EZR5G VM2P170EZGLG VM2P170EZR1G VM2P170EZR5G VM2P170EZS5G
175 6Tri VM1P176EZGLG VM1P176EZR1G VM1P176EZR5G VM2P176EZGLG VM2P176EZR1G VM2P176EZR5G VM2P176EZS5G
M152 480 VM1P175EZGLG VM1P175EZR1G VM1P175EZR5G VM2P175EZGLG VM2P175EZR1G VM2P175EZR5G VM2P175EZS5G
CERTILITE®V SERIES LIGHTING
METAL HALIDE/METAL HALIDE PULSE, 50-175W MEDIUM BASE HID L65
L
1See hazardous location data pages L104-107 for application suitability.
2Catalog numbers shown are with Guard; to omit guard change ending G to N; e.g. VM1H050D4GLN.
3Catalog numbers shown are with 1-1/2" conduit openings; change “5” to “4” for 1-1/4" e.g. VM1H050D4GLG.
4Consult catalog logic for other available voltage & lamp combinations.
5Add suffix NR for AEx nR Restricted Breathing; see page L54 for more information.
** 50, 70, & 100 Watt “Traditional Metal Hallide” ballasts include a Pulse Ignitor, as do 150 & 175W Metal Halide Pulse models.
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
VM 50-175 METAL HALIDE (PULSE**) - STANCHION 25° ANGLE
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
50 M110 1-1/2" Quad VM1H050D5GLG VM1H050D5R1G VM1H050D5R5G VM2H050D5GLG VM2H050D5R1G VM2H050D5R5G VM2H050D5S5G
Tri VM1H056D5GLG VM1H056D5R1G VM1H056D5R5G VM2H056D5GLG VM2H056D5R1G VM2H056D5R5G VM2H056D5S5G
Quad VM1H070D5GLG VM1H070D5R1G VM1H070D5R5G VM2H070D5GLG VM2H070D5R1G VM2H070D5R5G VM2H070D5S5G
70 M98 1-1/2" Tri VM1H076D5GLG VM1H076D5R1G VM1H076D5R5G VM2H076D5GLG VM2H076D5R1G VM2H076D5R5G VM2H076D5S5G
480 VM1H075D5GLG VM1H075D5R1G VM1H075D5R5G VM2H075D5GLG VM2H075D5R1G VM2H075D5R5G VM2H075D5S5G
Quad VM1H100D5GLG VM1H100D5R1G VM1H100D5R5G VM2H100D5GLG VM2H100D5R1G VM2H100D5R5G VM2H100D5S5G
100 M90 1-1/2" Tri VM1H106D5GLG VM1H106D5R1G VM1H106D5R5G VM2H106D5GLG VM2H106D5R1G VM2H106D5R5G VM2H106D5S5G
480 VM1H105D5GLG VM1H105D5R1G VM1H105D5R5G VM2H105D5GLG VM2H105D5R1G VM2H105D5R5G VM2H105D5S5G
M102 Quad VM1P150D5GLG VM1P150D5R1G VM1P150D5R5G VM2P150D5GLG VM2P150D5R1G VM2P150D5R5G VM2P150D5S5G
150 1-1/2" Tri VM1P156D5GLG VM1P156D5R1G VM1P156D5R5G VM2P156D5GLG VM2P156D5R1G VM2P156D5R5G VM2P156D5S5G
M142 480 VM1P155D5GLG VM1P155D5R1G VM1P155D5R5G VM2P155D5GLG VM2P155D5R1G VM2P155D5R5G VM2P155D5S5G
M137 Quad VM1P170D5GLG VM1P170D5R1G VM1P170D5R5G VM2P170D5GLG VM2P170D5R1G VM2P170D5R5G VM2P170D5S5G
175 1-1/2" Tri VM1P176D5GLG VM1P176D5R1G VM1P176D5R5G VM2P176D5GLG VM2P176D5R1G VM2P176D5R5G VM2P176D5S5G
M152 480 VM1P175D5GLG VM1P175D5R1G VM1P175D5R5G VM2P175D5GLG VM2P175D5R1G VM2P175D5R5G VM2P175D5S5G
VM 50-175 METAL HALIDE (PULSE**) - STANCHION STRAIGHT
DESCRIPTION
ANSI
HUB
SIZE3VOLTAGE4
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE I GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE V
REFRACTOR
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
50 M110 1-1/2" Quad VM1H050S5GLG VM1H050S5R1G VM1H050S5R5G VM2H050S5GLG VM2H050S5R1G VM2H050S5R5G VM2H050S5S5G
Tri VM1H056S5GLG VM1H056S5R1G VM1H056S5R5G VM2H056S5GLG VM2H056S5R1G VM2H056S5R5G VM2H056S5S5G
Quad VM1H070S5GLG VM1H070S5R1G VM1H070S5R5G VM2H070S5GLG VM2H070S5R1G VM2H070S5R5G VM2H070S5S5G
70 M98 1-1/2" Tri VM1H076S5GLG VM1H076S5R1G VM1H076S5R5G VM2H076S5GLG VM2H076S5R1G VM2H076S5R5G VM2H076S5S5G
480 VM1H075S5GLG VM1H075S5R1G VM1H075S5R5G VM2H075S5GLG VM2H075S5R1G VM2H075S5R5G VM2H075S5S5G
Quad VM1H100S5GLG VM1H100S5R1G VM1H100S5R5G VM2H100S5GLG VM2H100S5R1G VM2H100S5R5G VM2H100S5S5G
100 M90 1-1/2" Tri VM1H106S5GLG VM1H106S5R1G VM1H106S5R5G VM2H106S5GLG VM2H106S5R1G VM2H106S5R5G VM2H106S5S5G
480 VM1H105S5GLG VM1H105S5R1G VM1H105S5R5G VM2H105S5GLG VM2H105S5R1G VM2H105S5R5G VM2H105S5S5G
M102 Quad VM1P150S5GLG VM1P150S5R1G VM1P150S5R5G VM2P150S5GLG VM2P150S5R1G VM2P150S5R5G VM2P150S5S5G
150 1-1/2" Tri VM1P156S5GLG VM1P156S5R1G VM1P156S5R5G VM2P156S5GLG VM2P156S5R1G VM2P156S5R5G VM2P156S5S5G
M142 480 VM1P155S5GLG VM1P155S5R1G VM1P155S5R5G VM2P155S5GLG VM2P155S5R1G VM2P155S5R5G VM2P155S5S5G
M137 Quad VM1P170S5GLG VM1P170S5R1G VM1P170S5R5G VM2P170S5GLG VM2P170S5R1G VM2P170S5R5G VM2P170S5S5G
175 1-1/2" Tri VM1P176S5GLG VM1P176S5R1G VM1P176S5R5G VM2P176S5GLG VM2P176S5R1G VM2P176S5R5G VM2P176S5S5G
M152 480 VM1P175S5GLG VM1P175S5R1G VM1P175S5R5G VM2P175S5GLG VM2P175S5R1G VM2P175S5R5G VM2P175S5S5G
VM1 Stanchion
Straight
w/5-1/2"
Refractor & Guard
VM1 Stanchion 25°
w/5-1/2"
Globe & Guard
VM2 Stanchion 25°
w/7-3/4"
Globe & Guard
VM2 Stanchion
Straight
w/7-3/4"
Refractor & Guard
CERTILITE®V SERIES LIGHTING
VM3/VM4 CATALOG ORDERING LOGIC
L66
CertiLite®VCatalog Number Logic; 50-250 Low Wattage (Mogul Base) HID Fixtures
Series Constant
Optic Thread Size
3—5 1/2"
4—7 3/4"
Lamp Type
S—HPS (50, 70, 100, 150)
H—MH (70, 100, 175, 250)
P—MHP (1251, 150, 175, 200)
Voltage @ 60 Hertz
0—Quadri-Volt (120, 208, 240, 277)
5—480V
6—Tri - 120, 277, 347 (Canada)
7—220V
8—220/240 50 Hz
Mounting Type
A—Pendant
F—Flexible Pendant
X—Ceiling
B—Wall Bracket
C—Cone Top
E—EZ Mount Adapter2
D—Stanchion 25°
S—Stanchion Straight 90°
N—None (mount ordered
separately)3
Lamp Wattage
05—50W, (HPS)
07—70W, (HPS, MH)
10—100W, (HPS, MH)
12—125W, (MHP1)
15—150W, (HPS, MHP)
17—175W, (MH, MHP)
20—200W, (MHP)
25—250W, (MH)
Guard
G—Guard (Globes & Glass
refractors)
N—No Guard8
Options
IR—Instant Restrike - 50-150
HPS
QA—Quartz Auxiliary9
BP—Ballast Protector -
70-150 HPS
F1—Fusing 120V
F2—Fusing 208V
F3—Fusing 240V
F4—Fusing 277V
F5—Fusing 480V
F6—Fusing 347V
F7—Fusing 220V
F8—Fusing 240V 50 Hz
P1—Photocell 120V
P2—Photocell 208-277V
P3—Photocell 347V
Q1—QD Wired to 120V
Q2—QD Wired to 208V
Q3—QD Wired to 240V
Q4—QD Wired to 277V
Q5—QD Wired to 480V
Q6—QD Wired to 347V
Q7—QD 220V
Q8—QD 240V (50Hz)
TBx—Terminal Blocks
x= Voltage Code
AS—Assembled Fixture with
Standard Lamp
AD—Assembled Fixture with
Dual Arc Tube Lamp 70,
100, 150 HPS only
AN—Assembled, no lamp
CP—Component Pack-No
Lamp
CS—Component Pack with
Standard Lamp
Optic
GL—Globe (VM3, VM4)
R1—Type I Glass Refractor (VM3,
VM4)
R3—Type III Glass Refractor (VM4)
R5—Type V Glass Refractor (VM3,
VM4)
ER—Enclosed Reflector (VM4)
EP—Poylcarbonate Shielded
Enclosed Reflector (VM4)
S2—Type II 12" Spin-Top Refractor
(VM34, VM4)
S8—Type V 8" Spin-Top Refractor
(VM3)
S5—Type V 12" Spin-Top Refractor
(VM34, VM4)
P5—Type V 12" Plastic Spin-Top
Refractor (VM3-175W Max.)
FG—Silicone5Coated Globe (VM3,
VM4)
TG—Teflon®6Coated Globe (VM3,
VM4)
T1—Teflon®6Coated Globe Type I
Glass Refractor (VM3, VM4)
T3—Teflon®6Coated Globe Type III
Glass Refractor (VM4)
T5—Teflon®6Coated Globe Type V
Glass Refractor (VM3, VM4)
T2—Teflon®6Coated Type II 12"
Spin-Top Refractor (VM34,
VM4)
T8—Teflon®6Coated Type V 8"
Spin-Top Refractor (VM3)
TV—Teflon®6Coated Type V 12"
Spin-Top Refractor (VM34,
VM4)
Entry (Mounts available)
2—3/4" NPT (A,B,C,X)
3—1" NPT (A,B,C,X)
4—1 1/4" NPT (D,S)
5—1 1/2" NPT (D,S)
6—3/4" NPT 5-Hub (X)
7—1" NPT 5-Hub (X)
8—M20 4-Hub (X)
9—M20 5-Hub (X)
Z—EZ Mount Adapter2
N—None (mount ordered
separately)3
VM 0 0 00 0 0 0 00 0 (NR7) 00
1Special order lamp type/wattage not shown in grids, minimums apply.
2Completes as “EZ”, conduit mounting boxes ordered separately - See L83.
3NN mount ordered separately.
412" Spintops for use with VM3 tanks ship with a Mogul to Mogul socket
extender for enhanced photometrics vs. 7 3/4", which are used on VM5,
but will fit VM4.
5Silicone coated globe for additional impact protection.
6Teflon®is a registered trademark of DuPont, Inc.
Consult factory for available lamp and voltage combinations.
7Restricted Breathing - See L54 for more information.
8Order Guards for Spin-Tops & VMER40 separately.
9QA not suitable for Class I, Div. 2/Zone 2 applications; consult factory
for other hazardous applications.
Fusing not for Marine or Canadian installations.
Photo cells for Class I, Div. 2 only, or C1Z2 nR , - not Class II.
Field connection to proper tap in case of Multitap Ballasts.
Not for use with wall or straight (90°) Stanchion.
QD = Quick Disconnect. Allows easy tank removal for maintenance.
Electrician simply unplugs de-energized ballast from supply circuit.
220V 60Hz or 230V 50Hz used with QA-requires VM5 tank.
IR and BP cannot be ordered together.
®
11
12
13
13
14
15
15
16
11 12
11 12
11 12
14
16
16
14
14
14
14
14
14
V
V
175-250W
Old Style
MH are
Export only
EISA LAW
CERTILITE®V SERIES LIGHTING
HIGH PRESSURE SODIUM, 50-150W MOGUL BASE HID L67
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
Pendant
w/ Enclosed Reflector
Pendant
w/ 5-1/2"
Globe & Guard
Pendant
w/ 7-3/4"
Globe & Guard
Flexible Pendant
w/ 5-1/2"
Refractor & Guard
Flexible Pendant
w/ 7-3/4"
Refractor & Guard
VM 50-150 WATT HIGH PRESSURE SODIUM PENDANT
WATTS
50
70
100
150
DESCRIPTION
ANSI
S68
S62
S54
S55
HUB
SIZE3
3/4"
3/4"
3/4"
3/4"
VOLTAGE4
Quad
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3S050A2GLG
VM3S070A2GLG
VM3S076A2GLG
VM3S075A2GLG
VM3S100A2GLG
VM3S106A2GLG
VM3S105A2GLG
VM3S150A2GLG
VM3S156A2GLG
VM3S155A2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3S050A2R1G
VM3S070A2R1G
VM3S076A2R1G
VM3S075A2R1G
VM3S100A2R1G
VM3S106A2R1G
VM3S105A2R1G
VM3S150A2R1G
VM3S156A2R1G
VM3S155A2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3S050A2R5G
VM3S070A2R5G
VM3S076A2R5G
VM3S075A2R5G
VM3S100A2R5G
VM3S106A2R5G
VM3S105A2R5G
VM3S150A2R5G
VM3S156A2R5G
VM3S155A2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4S050A2GLG
VM4S070A2GLG
VM4S076A2GLG
VM4S075A2GLG
VM4S100A2GLG
VM4S106A2GLG
VM4S105A2GLG
VM4S150A2GLG
VM4S156A2GLG
VM4S155A2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4S050A2R1G
VM4S070A2R1G
VM4S076A2R1G
VM4S075A2R1G
VM4S100A2R1G
VM4S106A2R1G
VM4S105A2R1G
VM4S150A2R1G
VM4S156A2R1G
VM4S155A2R1G
ENCLOSED
REFLECTOR
VM4S050A2ERN
VM4S070A2ERN
VM4S076A2ERN
VM4S075A2ERN
VM4S100A2ERN
VM4S106A2ERN
VM4S105A2ERN
VM4S150A2ERN
VM4S156A2ERN
VM4S155A2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4S050A2R5G
VM4S070A2R5G
VM4S076A2R5G
VM4S075A2R5G
VM4S100A2R5G
VM4S106A2R5G
VM4S105A2R5G
VM4S150A2R5G
VM4S156A2R5G
VM4S155A2R5G
VM 50-150 WATT HIGH PRESSURE SODIUM FLEXIBLE PENDANT
WATTS
50
70
100
150
DESCRIPTION
ANSI
S68
S62
S54
S55
HUB
SIZE 3
3/4"
3/4"
3/4"
3/4"
VOLTAG4
Quad
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3S050F2GLG
VM3S070F2GLG
VM3S076F2GLG
VM3S075F2GLG
VM3S100F2GLG
VM3S106F2GLG
VM3S105F2GLG
VM3S150F2GLG
VM3S156F2GLG
VM3S155F2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3S050F2R1G
VM3S070F2R1G
VM3S076F2R1G
VM3S075F2R1G
VM3S100F2R1G
VM3S106F2R1G
VM3S105F2R1G
VM3S150F2R1G
VM3S156F2R1G
VM3S155F2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3S050F2R5G
VM3S070F2R5G
VM3S076F2R5G
VM3S075F2R5G
VM3S100F2R5G
VM3S106F2R5G
VM3S105F2R5G
VM3S150F2R5G
VM3S156F2R5G
VM3S155F2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4S050F2GLG
VM4S070F2GLG
VM4S076F2GLG
VM4S075F2GLG
VM4S100F2GLG
VM4S106F2GLG
VM4S105F2GLG
VM4S150F2GLG
VM4S156F2GLG
VM4S155F2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4S050F2R1G
VM4S070F2R1G
VM4S076F2R1G
VM4S075F2R1G
VM4S100F2R1G
VM4S106F2R1G
VM4S105F2R1G
VM4S150F2R1G
VM4S156F2R1G
VM4S155F2R1G
ENCLOSED
REFLECTOR
VM4S050F2ERN
VM4S070F2ERN
VM4S076F2ERN
VM4S075F2ERN
VM4S100F2ERN
VM4S106F2ERN
VM4S105F2ERN
VM4S150F2ERN
VM4S156F2ERN
VM4S155F2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4S050F2R5G
VM4S070F2R5G
VM4S076F2R5G
VM4S075F2R5G
VM4S100F2R5G
VM4S106F2R5G
VM4S105F2R5G
VM4S150F2R5G
VM4S156F2R5G
VM4S155F2R5G
1See hazardous application data on pages L108-L111 for limitations.
2Catalog numbers shown are with guard (except enclosed reflector); to omit guard change ending G to N; e.g. VM3S050A2GLN
3Catalog numbers shown are with 3/4" conduit openings; change 2 to 3 for 1"; e.g. VM3S050A3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
L
CERTILITE®V SERIES LIGHTING
HIGH PRESSURE SODIUM, 50-150W MOGUL BASE HID
L68
Ceiling
w/ 5-1/2"
Globe & Guard
Ceiling
w/ 7-3/4"
Globe & Guard
Wall
w/ 5-1/2"
Refractor & Guard
Wall
w/ 7-3/4"
Refractor & Guard
Ceiling
w/ Enclosed Reflector
VM 50-150 WATT HIGH PRESSURE SODIUM CEILING
WATTS
50
70
100
150
DESCRIPTION
ANSI
S68
S62
S54
S55
HUB
SIZE3
3/4"
3/4"
3/4"
3/4"
VOLTAGE3
Quad
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3S050X2GLG
VM3S070X2GLG
VM3S076X2GLG
VM3S075X2GLG
VM3S100X2GLG
VM3S106X2GLG
VM3S105X2GLG
VM3S150X2GLG
VM3S156X2GLG
VM3S155X2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3S050X2R1G
VM3S070X2R1G
VM3S076X2R1G
VM3S075X2R1G
VM3S100X2R1G
VM3S106X2R1G
VM3S105X2R1G
VM3S150X2R1G
VM3S156X2R1G
VM3S155X2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3S050X2R5G
VM3S070X2R5G
VM3S076X2R5G
VM3S075X2R5G
VM3S100X2R5G
VM3S106X2R5G
VM3S105X2R5G
VM3S150X2R5G
VM3S156X2R5G
VM3S155X2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4S050X2GLG
VM4S070X2GLG
VM4S076X2GLG
VM4S075X2GLG
VM4S100X2GLG
VM4S106X2GLG
VM4S105X2GLG
VM4S150X2GLG
VM4S156X2GLG
VM4S155X2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4S050X2R1G
VM4S070X2R1G
VM4S076X2R1G
VM4S075X2R1G
VM4S100X2R1G
VM4S106X2R1G
VM4S105X2R1G
VM4S150X2R1G
VM4S156X2R1G
VM4S155X2R1G
ENCLOSED
REFLECTOR
VM4S050X2ERN
VM4S070X2ERN
VM4S076X2ERN
VM4S075X2ERN
VM4S100X2ERN
VM4S106X2ERN
VM4S105X2ERN
VM4S150X2ERN
VM4S156X2ERN
VM4S155X2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4S050X2R5G
VM4S070X2R5G
VM4S076X2R5G
VM4S075X2R5G
VM4S100X2R5G
VM4S106X2R5G
VM4S105X2R5G
VM4S150X2R5G
VM4S156X2R5G
VM4S155X2R5G
VM 50-150 WATT HIGH PRESSURE SODIUM WALL
WATTS
50
70
100
150
DESCRIPTION
ANSI
S68
S62
S54
S55
HUB
SIZE3
3/4"
3/4"
3/4"
3/4"
VOLTAGE4
Quad
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3S050B2GLG
VM3S070B2GLG
VM3S076B2GLG
VM3S075B2GLG
VM3S100B2GLG
VM3S106B2GLG
VM3S105B2GLG
VM3S150B2GLG
VM3S156B2GLG
VM3S155B2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3S050B2R1G
VM3S070B2R1G
VM3S076B2R1G
VM3S075B2R1G
VM3S100B2R1G
VM3S106B2R1G
VM3S105B2R1G
VM3S150B2R1G
VM3S156B2R1G
VM3S155B2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3S050B2R5G
VM3S070B2R5G
VM3S076B2R5G
VM3S075B2R5G
VM3S100B2R5G
VM3S106B2R5G
VM3S105B2R5G
VM3S150B2R5G
VM3S156B2R5G
VM3S155B2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4S050B2GLG
VM4S070B2GLG
VM4S076B2GLG
VM4S075B2GLG
VM4S100B2GLG
VM4S106B2GLG
VM4S105B2GLG
VM4S150B2GLG
VM4S156B2GLG
VM4S155B2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4S050B2R1G
VM4S070B2R1G
VM4S076B2R1G
VM4S075B2R1G
VM4S100B2R1G
VM4S106B2R1G
VM4S105B2R1G
VM4S150B2R1G
VM4S156B2R1G
VM4S155B2R1G
ENCLOSED
REFLECTOR
VM4S050B2ERN
VM4S070B2ERN
VM4S076B2ERN
VM4S075B2ERN
VM4S100B2ERN
VM4S106B2ERN
VM4S105B2ERN
VM4S150B2ERN
VM4S156B2ERN
VM4S155B2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4S050B2R5G
VM4S070B2R5G
VM4S076B2R5G
VM4S075B2R5G
VM4S100B2R5G
VM4S106B2R5G
VM4S105B2R5G
VM4S150B2R5G
VM4S156B2R5G
VM4S155B2R5G
1See hazardous application data on pages L108-L111 for limitations.
2Catalog numbers shown are with guard, to omit guard (except enclosed reflector); change ending G to N; e.g. VM3S050X2GLN
3Catalog numbers shown are with 3/4" conduit openings, change 2 to 3 for 1"; e.g. VM3S050X3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
CERTILITE®V SERIES LIGHTING
HIGH PRESSURE SODIUM, 50-150W MOGUL BASE HID L69
L
Cone
w/ 5-1/2"
Globe & Guard
Cone
w/ 7-3/4"
Globe & Guard
EZ Adapter
w/ 5-1/2"
Refractor & Guard
EZ Adapter
w/ 7-3/4"
Refractor & Guard
Cone
w/ Enclosed Reflector
VM 50-150 WATT HIGH PRESSURE SODIUM CONE
WATTS
50
70
100
150
DESCRIPTION
ANSI
S68
S62
S54
S55
HUB
SIZE3
3/4"
3/4"
3/4"
3/4"
VOLTAGE4
Quad
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3S050C2GLG
VM3S070C2GLG
VM3S076C2GLG
VM3S075C2GLG
VM3S100C2GLG
VM3S106C2GLG
VM3S105C2GLG
VM3S150C2GLG
VM3S156C2GLG
VM3S155C2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3S050C2R1G
VM3S070C2R1G
VM3S076C2R1G
VM3S075C2R1G
VM3S100C2R1G
VM3S106C2R1G
VM3S105C2R1G
VM3S150C2R1G
VM3S156C2R1G
VM3S155C2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3S050C2R5G
VM3S070C2R5G
VM3S076C2R5G
VM3S075C2R5G
VM3S100C2R5G
VM3S106C2R5G
VM3S105C2R5G
VM3S150C2R5G
VM3S156C2R5G
VM3S155C2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4S050C2GLG
VM4S070C2GLG
VM4S076C2GLG
VM4S075C2GLG
VM4S100C2GLG
VM4S106C2GLG
VM4S105C2GLG
VM4S150C2GLG
VM4S156C2GLG
VM4S155C2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4S050C2R1G
VM4S070C2R1G
VM4S076C2R1G
VM4S075C2R1G
VM4S100C2R1G
VM4S106C2R1G
VM4S105C2R1G
VM4S150C2R1G
VM4S156C2R1G
VM4S155C2R1G
ENCLOSED
REFLECTOR
VM4S050C2ERN
VM4S070C2ERN
VM4S076C2ERN
VM4S075C2ERN
VM4S100C2ERN
VM4S106C2ERN
VM4S105C2ERN
VM4S150C2ERN
VM4S156C2ERN
VM4S155C2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4S050C2R5G
VM4S070C2R5G
VM4S076C2R5G
VM4S075C2R5G
VM4S100C2R5G
VM4S106C2R5G
VM4S105C2R5G
VM4S150C2R5G
VM4S156C2R5G
VM4S155C2R5G
WATTS
50
70
100
150
DESCRIPTION
ANSI
S68
S62
S54
S55
HUB
SIZE6
6
6
6
6
VOLTAGE4
Quad
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3S050EZGLG
VM3S070EZGLG
VM3S076EZGLG
VM3S075EZGLG
VM3S100EZGLG
VM3S106EZGLG
VM3S105EZGLG
VM3S150EZGLG
VM3S156EZGLG
VM3S155EZGLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3S050EZR1G
VM3S070EZR1G
VM3S076EZR1G
VM3S075EZR1G
VM3S100EZR1G
VM3S106EZR1G
VM3S105EZR1G
VM3S150EZR1G
VM3S156EZR1G
VM3S155EZR1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3S050EZR5G
VM3S070EZR5G
VM3S076EZR5G
VM3S075EZR5G
VM3S100EZR5G
VM3S106EZR5G
VM3S105EZR5G
VM3S150EZR5G
VM3S156EZR5G
VM3S155EZR5G
7-3/4" OPTIC THREAD SIZE 3
GLOBE
& GUARD
VM4S050EZGLG
VM4S070EZGLG
VM4S076EZGLG
VM4S075EZGLG
VM4S100EZGLG
VM4S106EZGLG
VM4S105EZGLG
VM4S150EZGLG
VM4S156EZGLG
VM4S155EZGLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4S050EZR1G
VM4S070EZR1G
VM4S076EZR1G
VM4S075EZR1G
VM4S100EZR1G
VM4S106EZR1G
VM4S105EZR1G
VM4S150EZR1G
VM4S156EZR1G
VM4S155EZR1G
ENCLOSED
REFLECTOR
VM4S050EZERN
VM4S070EZERN
VM4S076EZERN
VM4S075EZERN
VM4S100EZERN
VM4S106EZERN
VM4S105EZERN
VM4S150EZERN
VM4S156EZERN
VM4S155EZERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4S050EZR5G
VM4S070EZR5G
VM4S076EZR5G
VM4S075EZR5G
VM4S100EZR5G
VM4S106EZR5G
VM4S105EZR5G
VM4S150EZR5G
VM4S156EZR5G
VM4S155EZR5G
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
VM 50-150 WATT HIGH PRESSURE SODIUM EZ ADAPTER6
1See hazardous application data on pages L108-L111 for limitations.
2Catalog numbers shown are with guard (except enclosed reflector); to omit guard change ending G to N; e.g. VM3S050C2GLN
3Cone top catalog numbers shown are with 3/4" conduit openings, change 2 to 3 for 1"; e.g. VM3S050C3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
6VMEZA tank adapters UL “classified” as an assembly for use between VM tanks and EZ mounts. Order EZ mounts separately. See page L83.
CERTILITE®V SERIES LIGHTING
HIGH PRESSURE SODIUM, 50-150W MOGUL BASE HID
L70
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
Stanchion 25°
w/ 5-1/2"
Globe & Guard
Stanchion 25°
w/ 7-3/4"
Globe & Guard
Stanchion Straight
w/ 5-1/2"
Refractor & Guard
Stanchion Straight
w/ 7-3/4"
Refractor & Guard
Stanchion 25°
w/ Enclosed Reflector
VM 50-150 WATT HIGH PRESSURE SODIUM STANCHION 25° ANGLE
WATTS
50
70
100
150
DESCRIPTION
ANSI
S68
S62
S54
S55
HUB
SIZE3
1-1/2"
1-1/2"
1-1/2"
1-1/2"
VOLTAGE4
Quad
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3S050D5GLG
VM3S070D5GLG
VM3S076D5GLG
VM3S075D5GLG
VM3S100D5GLG
VM3S106D5GLG
VM3S105D5GLG
VM3S150D5GLG
VM3S156D5GLG
VM3S155D5GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3S050D5R1G
VM3S070D5R1G
VM3S076D5R1G
VM3S075D5R1G
VM3S100D5R1G
VM3S106D5R1G
VM3S105D5R1G
VM3S150D5R1G
VM3S156D5R1G
VM3S155D5R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3S050D5R5G
VM3S070D5R5G
VM3S076D5R5G
VM3S075D5R5G
VM3S100D5R5G
VM3S106D5R5G
VM3S105D5R5G
VM3S150D5R5G
VM3S156D5R5G
VM3S155D5R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4S050D5GLG
VM4S070D5GLG
VM4S076D5GLG
VM4S075D5GLG
VM4S100D5GLG
VM4S106D5GLG
VM4S105D5GLG
VM4S150D5GLG
VM4S156D5GLG
VM4S155D5GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4S050D5R1G
VM4S070D5R1G
VM4S076D5R1G
VM4S075D5R1G
VM4S100D5R1G
VM4S106D5R1G
VM4S105D5R1G
VM4S150D5R1G
VM4S156D5R1G
VM4S155D5R1G
ENCLOSED
REFLECTOR
VM4S050D5ERN
VM4S070D5ERN
VM4S076D5ERN
VM4S075D5ERN
VM4S100D5ERN
VM4S106D5ERN
VM4S105D5ERN
VM4S150D5ERN
VM4S156D5ERN
VM4S155D5ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4S050D5R5G
VM4S070D5R5G
VM4S076D5R5G
VM4S075D5R5G
VM4S100D5R5G
VM4S106D5R5G
VM4S105D5R5G
VM4S150D5R5G
VM4S156D5R5G
VM4S155D5R5G
VM 50-150 WATT HIGH PRESSURE SODIUM STANCHION STRAIGHT
WATTS
50
70
100
150
DESCRIPTION
ANSI
S68
S62
S54
S55
HUB
SIZE3
1-1/2"
1-1/2"
1-1/2"
1-1/2"
VOLTAGE4
Quad
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3S050S5GLG
VM3S070S5GLG
VM3S076S5GLG
VM3S075S5GLG
VM3S100S5GLG
VM3S106S5GLG
VM3S105S5GLG
VM3S150S5GLG
VM3S156S5GLG
VM3S155S5GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3S050S5R1G
VM3S070S5R1G
VM3S076S5R1G
VM3S075S5R1G
VM3S100S5R1G
VM3S106S5R1G
VM3S105S5R1G
VM3S150S5R1G
VM3S156S5R1G
VM3S155S5R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3S050S5R5G
VM3S070S5R5G
VM3S076S5R5G
VM3S075S5R5G
VM3S100S5R5G
VM3S106S5R5G
VM3S105S5R5G
VM3S150S5R5G
VM3S156S5R5G
VM3S155S5R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4S050S5GLG
VM4S070S5GLG
VM4S076S5GLG
VM4S075S5GLG
VM4S100S5GLG
VM4S106S5GLG
VM4S105S5GLG
VM4S150S5GLG
VM4S156S5GLG
VM4S155S5GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4S050S5R1G
VM4S070S5R1G
VM4S076S5R1G
VM4S075S5R1G
VM4S100S5R1G
VM4S106S5R1G
VM4S105S5R1G
VM4S150S5R1G
VM4S156S5R1G
VM4S155S5R1G
ENCLOSED
REFLECTOR
VM4S050S5ERN
VM4S070S5ERN
VM4S076S5ERN
VM4S075S5ERN
VM4S100S5ERN
VM4S106S5ERN
VM4S105S5ERN
VM4S150S5ERN
VM4S156S5ERN
VM4S155S5ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4S050S5R5G
VM4S070S5R5G
VM4S076S5R5G
VM4S075S5R5G
VM4S100S5R5G
VM4S106S5R5G
VM4S105S5R5G
VM4S150S5R5G
VM4S156S5R5G
VM4S155S5R5G
1See hazardous application data on pages L108-L111 for limitations.
2Catalog numbers shown are with guard (except enclosed reflector); to omit guard change ending G to N; e.g. VM3S050D5GLN
3Catalog numbers shown are with 1-1/2" conduit openings, change 5 to 4 for 1-1/4"; e.g. VM3S050D4GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
VM 70-250 WATT METAL HALIDE FLEXIBLE PENDANT
WATTS
70
100
175
6
250
6
DESCRIPTION
ANSI
M98
M143
M90
M140
M57
M58
HUB
SIZE3
3/4"
3/4"
3/4"
3/4"
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3H070F2GLG
VM3H076F2GLG
VM3H075F2GLG
VM3H100F2GLG
VM3H106F2GLG
VM3H105F2GLG
VM3H170F2GLG
VM3H176F2GLG
VM3H175F2GLG
VM3H250F2GLG
VM3H256F2GLG
VM3H255F2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3H070F2R1G
VM3H076F2R1G
VM3H075F2R1G
VM3H100F2R1G
VM3H106F2R1G
VM3H105F2R1G
VM3H170F2R1G
VM3H176F2R1G
VM3H175F2R1G
VM3H250F2R1G
VM3H256F2R1G
VM3H255F2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3H070F2R5G
VM3H076F2R5G
VM3H075F2R5G
VM3H100F2R5G
VM3H106F2R5G
VM3H105F2R5G
VM3H170F2R5G
VM3H176F2R5G
VM3H175F2R5G
VM3H250F2R5G
VM3H256F2R5G
VM3H255F2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4H070F2GLG
VM4H076F2GLG
VM4H075F2GLG
VM4H100F2GLG
VM4H106F2GLG
VM4H105F2GLG
VM4H170F2GLG
VM4H176F2GLG
VM4H175F2GLG
VM4H250F2GLG
VM4H256F2GLG
VM4H255F2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4H070F2R1G
VM4H076F2R1G
VM4H075F2R1G
VM4H100F2R1G
VM4H106F2R1G
VM4H105F2R1G
VM4H170F2R1G
VM4H176F2R1G
VM4H175F2R1G
VM4H250F2R1G
VM4H256F2R1G
VM4H255F2R1G
ENCLOSED
REFLECTOR
VM4H070F2ERN
VM4H076F2ERN
VM4H075F2ERN
VM4H100F2ERN
VM4H106F2ERN
VM4H105F2ERN
VM4H170F2ERN
VM4H176F2ERN
VM4H175F2ERN
VM4H250F2ERN
VM4H256F2ERN
VM4H255F2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4H070F2R5G
VM4H076F2R5G
VM4H075F2R5G
VM4H100F2R5G
VM4H106F2R5G
VM4H105F2R5G
VM4H170F2R5G
VM4H176F2R5G
VM4H175F2R5G
VM4H250F2R5G
VM4H256F2R5G
VM4H255F2R5G
CERTILITE®V SERIES LIGHTING
METAL HALIDE, 70-250W MOGUL BASE HID L71
L
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
WATTS
70
100
175
6
250
6
DESCRIPTION
ANSI
M98
M143
M90
M140
M57
M58
HUB
SIZE3
3/4"
3/4"
3/4"
3/4"
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3H070A2GLG
VM3H076A2GLG
VM3H075A2GLG
VM3H100A2GLG
VM3H106A2GLG
VM3H105A2GLG
VM3H170A2GLG
VM3H176A2GLG
VM3H175A2GLG
VM3H250A2GLG
VM3H256A2GLG
VM3H255A2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3H070A2R1G
VM3H076A2R1G
VM3H075A2R1G
VM3H100A2R1G
VM3H106A2R1G
VM3H105A2R1G
VM3H170A2R1G
VM3H176A2R1G
VM3H175A2R1G
VM3H250A2R1G
VM3H256A2R1G
VM3H255A2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3H070A2R5G
VM3H076A2R5G
VM3H075A2R5G
VM3H100A2R5G
VM3H106A2R5G
VM3H105A2R5G
VM3H170A2R5G
VM3H176A2R5G
VM3H175A2R5G
VM3H250A2R5G
VM3H256A2R5G
VM3H255A2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4H070A2GLG
VM4H076A2GLG
VM4H075A2GLG
VM4H100A2GLG
VM4H106A2GLG
VM4H105A2GLG
VM4H170A2GLG
VM4H176A2GLG
VM4H175A2GLG
VM4H250A2GLG
VM4H256A2GLG
VM4H255A2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4H070A2R1G
VM4H076A2R1G
VM4H075A2R1G
VM4H100A2R1G
VM4H106A2R1G
VM4H105A2R1G
VM4H170A2R1G
VM4H176A2R1G
VM4H175A2R1G
VM4H250A2R1G
VM4H256A2R1G
VM4H255A2R1G
ENCLOSED
REFLECTOR
VM4H070A2ERN
VM4H076A2ERN
VM4H075A2ERN
VM4H100A2ERN
VM4H106A2ERN
VM4H105A2ERN
VM4H170A2ERN
VM4H176A2ERN
VM4H175A2ERN
VM4H250A2ERN
VM4H256A2ERN
VM4H255A2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4H070A2R5G
VM4H076A2R5G
VM4H075A2R5G
VM4H100A2R5G
VM4H106A2R5G
VM4H105A2R5G
VM4H170A2R5G
VM4H176A2R5G
VM4H175A2R5G
VM4H250A2R5G
VM4H256A2R5G
VM4H255A2R5G
1See hazardous application data on pages L108-L111 for limitations.
2Catalog numbers shown are with guard (except enclosed reflector); to omit guard change ending G to N; e.g. VM3H070A2GLN
3Catalog numbers shown are with 3/4" conduit openings, change 2 to 3 for 1"; e.g. VM3H070A3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
6175W M57 & 250W M58 Fixtures are EXPORT ONLY (EISA LAW).
Pendant
w/ Enclosed Reflector
Pendant
w/ 5-1/2"
Globe & Guard
Pendant
w/ 7-3/4"
Globe & Guard
Flexible Pendant
w/ 5-1/2"
Refractor & Guard
Flexible Pendant
w/ 7-3/4"
Refractor & Guard
VM 70-250 WATT METAL HALIDE PENDANT
CERTILITE®V SERIES LIGHTING
METAL HALIDE, 70-250W MOGUL BASE HID
L72
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
WATTS
70
100
175
6
250
6
DESCRIPTION
ANSI
M98
M143
M90
M140
M57
M58
HUB
SIZE3
3/4"
3/4"
3/4"
3/4"
VOLTAGE3
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3H070X2GLG
VM3H076X2GLG
VM3H075X2GLG
VM3H100X2GLG
VM3H106X2GLG
VM3H105X2GLG
VM3H170X2GLG
VM3H176X2GLG
VM3H175X2GLG
VM3H250X2GLG
VM3H256X2GLG
VM3H255X2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3H070X2R1G
VM3H076X2R1G
VM3H075X2R1G
VM3H100X2R1G
VM3H106X2R1G
VM3H105X2R1G
VM3H170X2R1G
VM3H176X2R1G
VM3H175X2R1G
VM3H250X2R1G
VM3H256X2R1G
VM3H255X2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3H070X2R5G
VM3H076X2R5G
VM3H075X2R5G
VM3H100X2R5G
VM3H106X2R5G
VM3H105X2R5G
VM3H170X2R5G
VM3H176X2R5G
VM3H175X2R5G
VM3H250X2R5G
VM3H256X2R5G
VM3H255X2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4H070X2GLG
VM4H076X2GLG
VM4H075X2GLG
VM4H100X2GLG
VM4H106X2GLG
VM4H105X2GLG
VM4H170X2GLG
VM4H176X2GLG
VM4H175X2GLG
VM4H250X2GLG
VM4H256X2GLG
VM4H255X2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4H070X2R1G
VM4H076X2R1G
VM4H075X2R1G
VM4H100X2R1G
VM4H106X2R1G
VM4H105X2R1G
VM4H170X2R1G
VM4H176X2R1G
VM4H175X2R1G
VM4H250X2R1G
VM4H256X2R1G
VM4H255X2R1G
ENCLOSED
REFLECTOR
VM4H070X2ERN
VM4H076X2ERN
VM4H075X2ERN
VM4H100X2ERN
VM4H106X2ERN
VM4H105X2ERN
VM4H170X2ERN
VM4H176X2ERN
VM4H175X2ERN
VM4H250X2ERN
VM4H256X2ERN
VM4H255X2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4H070X2R5G
VM4H076X2R5G
VM4H075X2R5G
VM4H100X2R5G
VM4H106X2R5G
VM4H105X2R5G
VM4H170X2R5G
VM4H176X2R5G
VM4H175X2R5G
VM4H250X2R5G
VM4H256X2R5G
VM4H255X2R5G
1See hazardous application data on pages L108-L111 for limitations.
2Catalog numbers shown are with guard (except enclosed reflector); to omit guard change ending G to N; e.g. VM3H070X2GLN
3Catalog numbers shown are with 3/4" conduit openings, change 2 to 3 for 1"; e.g. VM3H070X3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
6175W M57 & 250W M58 Fixtures are EXPORT ONLY (EISA LAW).
VM 70-250 WATT METAL HALIDE WALL
WATTS
70
100
175
6
250
6
DESCRIPTION
ANSI
M98
M143
M90
M140
M57
M58
HUB
SIZE3
3/4"
3/4"
3/4"
3/4"
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3H070B2GLG
VM3H076B2GLG
VM3H075B2GLG
VM3H100B2GLG
VM3H106B2GLG
VM3H105B2GLG
VM3H170B2GLG
VM3H176B2GLG
VM3H175B2GLG
VM3H250B2GLG
VM3H256B2GLG
VM3H255B2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3H070B2R1G
VM3H076B2R1G
VM3H075B2R1G
VM3H100B2R1G
VM3H106B2R1G
VM3H105B2R1G
VM3H170B2R1G
VM3H176B2R1G
VM3H175B2R1G
VM3H250B2R1G
VM3H256B2R1G
VM3H255B2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3H070B2R5G
VM3H076B2R5G
VM3H075B2R5G
VM3H100B2R5G
VM3H106B2R5G
VM3H105B2R5G
VM3H170B2R5G
VM3H176B2R5G
VM3H175B2R5G
VM3H250B2R5G
VM3H256B2R5G
VM3H255B2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4H070B2GLG
VM4H076B2GLG
VM4H075B2GLG
VM4H100B2GLG
VM4H106B2GLG
VM4H105B2GLG
VM4H170B2GLG
VM4H176B2GLG
VM4H175B2GLG
VM4H250B2GLG
VM4H256B2GLG
VM4H255B2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4H070B2R1G
VM4H076B2R1G
VM4H075B2R1G
VM4H100B2R1G
VM4H106B2R1G
VM4H105B2R1G
VM4H170B2R1G
VM4H176B2R1G
VM4H175B2R1G
VM4H250B2R1G
VM4H256B2R1G
VM4H255B2R1G
ENCLOSED
REFLECTOR
VM4H070B2ERN
VM4H076B2ERN
VM4H075B2ERN
VM4H100B2ERN
VM4H106B2ERN
VM4H105B2ERN
VM4H170B2ERN
VM4H176B2ERN
VM4H175B2ERN
VM4H250B2ERN
VM4H256B2ERN
VM4H255B2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4H070B2R5G
VM4H076B2R5G
VM4H075B2R5G
VM4H100B2R5G
VM4H106B2R5G
VM4H105B2R5G
VM4H170B2R5G
VM4H176B2R5G
VM4H175B2R5G
VM4H250B2R5G
VM4H256B2R5G
VM4H255B2R5G
Ceiling
w/ 5-1/2"
Globe & Guard
Ceiling
w/ 7-3/4"
Globe & Guard
Wall
w/ 5-1/2"
Refractor & Guard
Wall
w/ 7-3/4"
Refractor & Guard
Ceiling
w/ Enclosed Reflector
VM 70-250 WATT METAL HALIDE CEILING
CERTILITE®V SERIES LIGHTING
METAL HALIDE, 70-250W MOGUL BASE HID L73
L
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
WATTS
70
100
175
6
250
6
DESCRIPTION
ANSI
M98
M143
M90
M140
M57
M58
HUB
SIZE3
3/4"
3/4"
3/4"
3/4"
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3H070C2GLG
VM3H076C2GLG
VM3H075C2GLG
VM3H100C2GLG
VM3H106C2GLG
VM3H105C2GLG
VM3H170C2GLG
VM3H176C2GLG
VM3H175C2GLG
VM3H250C2GLG
VM3H256C2GLG
VM3H255C2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3H070C2R1G
VM3H076C2R1G
VM3H075C2R1G
VM3H100C2R1G
VM3H106C2R1G
VM3H105C2R1G
VM3H170C2R1G
VM3H176C2R1G
VM3H175C2R1G
VM3H250C2R1G
VM3H256C2R1G
VM3H255C2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3H070C2R5G
VM3H076C2R5G
VM3H075C2R5G
VM3H100C2R5G
VM3H106C2R5G
VM3H105C2R5G
VM3H170C2R5G
VM3H176C2R5G
VM3H175C2R5G
VM3H250C2R5G
VM3H256C2R5G
VM3H255C2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4H070C2GLG
VM4H076C2GLG
VM4H075C2GLG
VM4H100C2GLG
VM4H106C2GLG
VM4H105C2GLG
VM4H170C2GLG
VM4H176C2GLG
VM4H175C2GLG
VM4H250C2GLG
VM4H256C2GLG
VM4H255C2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4H070C2R1G
VM4H076C2R1G
VM4H075C2R1G
VM4H100C2R1G
VM4H106C2R1G
VM4H105C2R1G
VM4H170C2R1G
VM4H176C2R1G
VM4H175C2R1G
VM4H250C2R1G
VM4H256C2R1G
VM4H255C2R1G
ENCLOSED
REFLECTOR
VM4H070C2ERN
VM4H076C2ERN
VM4H075C2ERN
VM4H100C2ERN
VM4H106C2ERN
VM4H105C2ERN
VM4H170C2ERN
VM4H176C2ERN
VM4H175C2ERN
VM4H250C2ERN
VM4H256C2ERN
VM4H255C2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4H070C2R5G
VM4H076C2R5G
VM4H075C2R5G
VM4H100C2R5G
VM4H106C2R5G
VM4H105C2R5G
VM4H170C2R5G
VM4H176C2R5G
VM4H175C2R5G
VM4H250C2R5G
VM4H256C2R5G
VM4H255C2R5G
1See hazardous application data on pages L108-L111 for limitations.
2Catalog numbers shown are with guard (except enclosed reflector); to omit guard change ending G to N; e.g. VM3H070C2GLN
3Catalog numbers shown are with 3/4" conduit openings, change 2 to 3 for 1"; e.g. VM3H070C3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
6175W M57 & 250W M58 Fixtures are EXPORT ONLY (EISA LAW).
7VMEZA tank adapters UL “classified” as an assembly for use between VM tanks and EZ mounts. Order EZ mounts separately.
See page L83.
VM 70-250 WATT METAL HALIDE EZ ADAPTER
WATTS
70
100
175
6
250
6
DESCRIPTION
ANSI
M98
M143
M90
M140
M57
M58
HUB
SIZE6
7
7
7
7
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3H070EZGLG
VM3H076EZGLG
VM3H075EZGLG
VM3H100EZGLG
VM3H106EZGLG
VM3H105EZGLG
VM3H170EZGLG
VM3H176EZGLG
VM3H175EZGLG
VM3H250EZGLG
VM3H256EZGLG
VM3H255EZGLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3H070EZR1G
VM3H076EZR1G
VM3H075EZR1G
VM3H100EZR1G
VM3H106EZR1G
VM3H105EZR1G
VM3H170EZR1G
VM3H176EZR1G
VM3H175EZR1G
VM3H250EZR1G
VM3H256EZR1G
VM3H255EZR1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3H070EZR5G
VM3H076EZR5G
VM3H075EZR5G
VM3H100EZR5G
VM3H106EZR5G
VM3H105EZR5G
VM3H170EZR5G
VM3H176EZR5G
VM3H175EZR5G
VM3H250EZR5G
VM3H256EZR5G
VM3H255EZR5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4H070EZGLG
VM4H076EZGLG
VM4H075EZGLG
VM4H100EZGLG
VM4H106EZGLG
VM4H105EZGLG
VM4H170EZGLG
VM4H176EZGLG
VM4H175EZGLG
VM4H250EZGLG
VM4H256EZGLG
VM4H255EZGLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4H070EZR1G
VM4H076EZR1G
VM4H075EZR1G
VM4H100EZR1G
VM4H106EZR1G
VM4H105EZR1G
VM4H170EZR1G
VM4H176EZR1G
VM4H175EZR1G
VM4H250EZR1G
VM4H256EZR1G
VM4H255EZR1G
ENCLOSED
REFLECTOR
VM4H070EZERN
VM4H076EZERN
VM4H075EZERN
VM4H100EZERN
VM4H106EZERN
VM4H105EZERN
VM4H170EZERN
VM4H176EZERN
VM4H175EZERN
VM4H250EZERN
VM4H256EZERN
VM4H255EZERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4H070EZR5G
VM4H076EZR5G
VM4H075EZR5G
VM4H100EZR5G
VM4H106EZR5G
VM4H105EZR5G
VM4H170EZR5G
VM4H176EZR5G
VM4H175EZR5G
VM4H250EZR5G
VM4H256EZR5G
VM4H255EZR5G
Cone
w/ 5-1/2"
Globe & Guard
Cone
w/ 7-3/4"
Globe & Guard
EZ Adapter
w/ 5-1/2"
Refractor & Guard
EZ Adapter
w/ 7-3/4"
Refractor & Guard
Cone
w/ Enclosed Reflector
VM 70-250 WATT METAL HALIDE CONE
CERTILITE®V SERIES LIGHTING
METAL HALIDE, 70-250W MOGUL BASE HID
L74
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
WATTS
70
100
175
6
250
6
DESCRIPTION
ANSI
M98
M143
M90
M140
M57
M58
HUB
SIZE3
1-1/2"
1-1/2"
1-1/2"
1-1/2"
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3H070D5GLG
VM3H076D5GLG
VM3H075D5GLG
VM3H100D5GLG
VM3H106D5GLG
VM3H105D5GLG
VM3H170D5GLG
VM3H176D5GLG
VM3H175D5GLG
VM3H250D5GLG
VM3H256D5GLG
VM3H255D5GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3H070D5R1G
VM3H076D5R1G
VM3H075D5R1G
VM3H100D5R1G
VM3H106D5R1G
VM3H105D5R1G
VM3H170D5R1G
VM3H176D5R1G
VM3H175D5R1G
VM3H250D5R1G
VM3H256D5R1G
VM3H255D5R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3H070D5R5G
VM3H076D5R5G
VM3H075D5R5G
VM3H100D5R5G
VM3H106D5R5G
VM3H105D5R5G
VM3H170D5R5G
VM3H176D5R5G
VM3H175D5R5G
VM3H250D5R5G
VM3H256D5R5G
VM3H255D5R5G
GLOBE
& GUARD
VM4H070D5GLG
VM4H076D5GLG
VM4H075D5GLG
VM4H100D5GLG
VM4H106D5GLG
VM4H105D5GLG
VM4H170D5GLG
VM4H176D5GLG
VM4H175D5GLG
VM4H250D5GLG
VM4H256D5GLG
VM4H255D5GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4H070D5R1G
VM4H076D5R1G
VM4H075D5R1G
VM4H100D5R1G
VM4H106D5R1G
VM4H105D5R1G
VM4H170D5R1G
VM4H176D5R1G
VM4H175D5R1G
VM4H250D5R1G
VM4H256D5R1G
VM4H255D5R1G
ENCLOSED
REFLECTOR
VM4H070D5ERN
VM4H076D5ERN
VM4H075D5ERN
VM4H100D5ERN
VM4H106D5ERN
VM4H105D5ERN
VM4H170D5ERN
VM4H176D5ERN
VM4H175D5ERN
VM4H250D5ERN
VM4H256D5ERN
VM4H255D5ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4H070D5R5G
VM4H076D5R5G
VM4H075D5R5G
VM4H100D5R5G
VM4H106D5R5G
VM4H105D5R5G
VM4H170D5R5G
VM4H176D5R5G
VM4H175D5R5G
VM4H250D5R5G
VM4H256D5R5G
VM4H255D5R5G
1See hazardous application data on pages L108-L111 for limitations.
2Catalog numbers shown are with guard (except enclosed reflector); to omit guard change ending G to N; e.g. VM3H070D5GLN
3Catalog numbers shown are with 3/4" conduit openings, change 5 to 4 for 1-1/4"; e.g. VM3H070D4GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
6175W M57 & 250W M58 Fixtures are EXPORT ONLY (EISA LAW).
VM 70-250 WATT METAL HALIDE STANCHION STRAIGHT
WATTS
70
100
175
6
250
6
DESCRIPTION
ANSI
M98
M143
M90
M140
M57
M58
HUB
SIZE3
1-1/2"
1-1/2"
1-1/2"
1-1/2"
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3H070S5GLG
VM3H076S5GLG
VM3H075S5GLG
VM3H100S5GLG
VM3H106S5GLG
VM3H105S5GLG
VM3H170S5GLG
VM3H176S5GLG
VM3H175S5GLG
VM3H250S5GLG
VM3H256S5GLG
VM3H255S5GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3H070S5R1G
VM3H076S5R1G
VM3H075S5R1G
VM3H100S5R1G
VM3H106S5R1G
VM3H105S5R1G
VM3H170S5R1G
VM3H176S5R1G
VM3H175S5R1G
VM3H250S5R1G
VM3H256S5R1G
VM3H255S5R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3H070S5R5G
VM3H076S5R5G
VM3H075S5R5G
VM3H100S5R5G
VM3H106S5R5G
VM3H105S5R5G
VM3H170S5R5G
VM3H176S5R5G
VM3H175S5R5G
VM3H250S5R5G
VM3H256S5R5G
VM3H255S5R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4H070S5GLG
VM4H076S5GLG
VM4H075S5GLG
VM4H100S5GLG
VM4H106S5GLG
VM4H105S5GLG
VM4H170S5GLG
VM4H176S5GLG
VM4H175S5GLG
VM4H250S5GLG
VM4H256S5GLG
VM4H255S5GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4H070S5R1G
VM4H076S5R1G
VM4H075S5R1G
VM4H100S5R1G
VM4H106S5R1G
VM4H105S5R1G
VM4H170S5R1G
VM4H176S5R1G
VM4H175S5R1G
VM4H250S5R1G
VM4H256S5R1G
VM4H255S5R1G
ENCLOSED
REFLECTOR
VM4H070S5ERN
VM4H076S5ERN
VM4H075S5ERN
VM4H100S5ERN
VM4H106S5ERN
VM4H105S5ERN
VM4H170S5ERN
VM4H176S5ERN
VM4H175S5ERN
VM4H250S5ERN
VM4H256S5ERN
VM4H255S5ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4H070S5R5G
VM4H076S5R5G
VM4H075S5R5G
VM4H100S5R5G
VM4H106S5R5G
VM4H105S5R5G
VM4H170S5R5G
VM4H176S5R5G
VM4H175S5R5G
VM4H250S5R5G
VM4H256S5R5G
VM4H255S5R5G
Stanchion 25°
w/ 5-1/2"
Globe & Guard
Stanchion 25°
w/ 7-3/4"
Globe & Guard
Stanchion Straight
w/ 5-1/2"
Refractor & Guard
Stanchion Straight
w/ 7-3/4"
Refractor & Guard
Stanchion 25°
w/ Enclosed Reflector
VM 70-250 WATT METAL HALIDE STANCHION 25° ANGLE
7-3/4" OPTIC THREAD SIZE 2
CERTILITE®V SERIES LIGHTING
METAL HALIDE PULSE, 150-200W MOGUL BASE HID L75
L
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
Pendant
w/ Enclosed Reflector
Flexible Pendant
w/ 7-3/4"
Refractor & Guard
Pendant
w/ 7-3/4"
Globe & Guard
VM 150-200 WATT METAL HALIDE PULSE PENDANT
WATTS
150
175
200
DESCRIPTION
ANSI
M102
M142
M137
M152
M136
HUB
SIZE3
3/4"
3/4"
3/4"
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3P150A2GLG
VM3P156A2GLG
VM3P155A2GLG
VM3P170A2GLG
VM3P176A2GLG
VM3P175A2GLG
VM3P200A2GLG
VM3P206A2GLG
VM3P205A2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3P150A2R1G
VM3P156A2R1G
VM3P155A2R1G
VM3P170A2R1G
VM3P176A2R1G
VM3P175A2R1G
VM3P200A2R1G
VM3P206A2R1G
VM3P205A2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3P150A2R5G
VM3P156A2R5G
VM3P155A2R5G
VM3P170A2R5G
VM3P176A2R5G
VM3P175A2R5G
VM3P200A2R5G
VM3P206A2R5G
VM3P205A2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4P150A2GLG
VM4P156A2GLG
VM4P155A2GLG
VM4P170A2GLG
VM4P176A2GLG
VM4P175A2GLG
VM4P200A2GLG
VM4P206A2GLG
VM4P205A2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4P150A2R1G
VM4P156A2R1G
VM4P155A2R1G
VM4P170A2R1G
VM4P176A2R1G
VM4P175A2R1G
VM4P200A2R1G
VM4P206A2R1G
VM4P205A2R1G
ENCLOSED
REFLECTOR
VM4P156A2ERN
VM4P155A2ERN
VM4P170A2ERN
VM4P170A2ERN
VM4P176A2ERN
VM4P175A2ERN
VM4P200A2ERN
VM4P206A2ERN
VM4P205A2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4P150A2R5G
VM4P156A2R5G
VM4P155A2R5G
VM4P170A2R5G
VM4P176A2R5G
VM4P175A2R5G
VM4P200A2R5G
VM4P206A2R5G
VM4P205A2R5G
VM 150-200 WATT METAL HALIDE PULSE FLEXIBLE PENDANT
WATTS
150
175
200
DESCRIPTION
ANSI
M102
M142
M137
M152
M136
HUB
SIZE3
3/4"
3/4"
3/4"
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3P150F2GLG
VM3P156F2GLG
VM3P155F2GLG
VM3P170F2GLG
VM3P176F2GLG
VM3P175F2GLG
VM3P200F2GLG
VM3P206F2GLG
VM3P205F2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3P150F2R1G
VM3P156F2R1G
VM3P155F2R1G
VM3P170F2R1G
VM3P176F2R1G
VM3P175F2R1G
VM3P200F2R1G
VM3P206F2R1G
VM3P205F2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3P150F2R5G
VM3P156F2R5G
VM3P155F2R5G
VM3P170F2R5G
VM3P176F2R5G
VM3P175F2R5G
VM3P200F2R5G
VM3P206F2R5G
VM3P205F2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4P150F2GLG
VM4P156F2GLG
VM4P155F2GLG
VM4P170F2GLG
VM4P176F2GLG
VM4P175F2GLG
VM4P200F2GLG
VM4P206F2GLG
VM4P205F2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4P150F2R1G
VM4P156F2R1G
VM4P155F2R1G
VM4P170F2R1G
VM4P176F2R1G
VM4P175F2R1G
VM4P200F2R1G
VM4P206F2R1G
VM4P205F2R1G
ENCLOSED
REFLECTOR
VM4P156F2ERN
VM4P155F2ERN
VM4P170F2ERN
VM4P170F2ERN
VM4P176F2ERN
VM4P175F2ERN
VM4P200F2ERN
VM4P206F2ERN
VM4P205F2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4P150F2R5G
VM4P156F2R5G
VM4P155F2R5G
VM4P170F2R5G
VM4P176F2R5G
VM4P175F2R5G
VM4P200F2R5G
VM4P206F2R5G
VM4P205F2R5G
1See hazardous application data on pages L108-L111 for limitations.
2Catalog numbers shown are with guard (except enclosed reflector); to omit guard change ending G to N; e.g. VM3P150A2GLN
3Catalog numbers shown are with 3/4" conduit openings; change 2 to 3 for 1"; e.g. VM3P150A3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
Pendant
w/ 5-1/2"
Globe & Guard
Flexible Pendant
w/ 5-1/2"
Refractor & Guard
CERTILITE®V SERIES LIGHTING
METAL HALIDE PULSE, 150-200W MOGUL BASE HID
L76
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
Ceiling
w/ 5-1/2"
Globe & Guard
Ceiling
w/ 7-3/4"
Globe & Guard
Wall
w/ 5-1/2"
Refractor & Guard
Wall
w/ 7-3/4"
Refractor & Guard
Ceiling
w/ Enclosed Reflector
VM 150-200 WATT METAL HALIDE PULSE CEILING
WATTS
150
175
200
DESCRIPTION
ANSI
M102
M142
M137
M152
M136
HUB
SIZE3
3/4"
3/4"
3/4"
VOLTAGE3
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3P150X2GLG
VM3P156X2GLG
VM3P155X2GLG
VM3P170X2GLG
VM3P176X2GLG
VM3P175X2GLG
VM3P200X2GLG
VM3P206X2GLG
VM3P205X2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3P150X2R1G
VM3P156X2R1G
VM3P155X2R1G
VM3P170X2R1G
VM3P176X2R1G
VM3P175X2R1G
VM3P200X2R1G
VM3P206X2R1G
VM3P205X2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3P150X2R5G
VM3P156X2R5G
VM3P155X2R5G
VM3P170X2R5G
VM3P176X2R5G
VM3P175X2R5G
VM3P200X2R5G
VM3P206X2R5G
VM3P205X2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4P150X2GLG
VM4P156X2GLG
VM4P155X2GLG
VM4P170X2GLG
VM4P176X2GLG
VM4P175X2GLG
VM4P200X2GLG
VM4P206X2GLG
VM4P205X2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4P150X2R1G
VM4P156X2R1G
VM4P155X2R1G
VM4P170X2R1G
VM4P176X2R1G
VM4P175X2R1G
VM4P200X2R1G
VM4P206X2R1G
VM4P205X2R1G
ENCLOSED
REFLECTOR
VM4P150X2ERN
VM4P156X2ERN
VM4P155X2ERN
VM4P170X2ERN
VM4P176X2ERN
VM4P175X2ERN
VM4P200X2ERN
VM4P206X2ERN
VM4P205X2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4P150X2R5G
VM4P156X2R5G
VM4P155X2R5G
VM4P170X2R5G
VM4P176X2R5G
VM4P175X2R5G
VM4P200X2R5G
VM4P206X2R5G
VM4P205X2R5G
VM 150-200 WATT METAL HALIDE PULSE WALL
WATTS
150
175
200
DESCRIPTION
ANSI
M102
M142
M137
M152
M136
HUB
SIZE3
3/4"
3/4"
3/4"
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
GLOBE
& GUARD
VM3P150B2GLG
VM3P156B2GLG
VM3P155B2GLG
VM3P170B2GLG
VM3P176B2GLG
VM3P175B2GLG
VM3P200B2GLG
VM3P206B2GLG
VM3P205B2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3P150B2R1G
VM3P156B2R1G
VM3P155B2R1G
VM3P170B2R1G
VM3P176B2R1G
VM3P175B2R1G
VM3P200B2R1G
VM3P206B2R1G
VM3P205B2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3P150B2R5G
VM3P156B2R5G
VM3P155B2R5G
VM3P170B2R5G
VM3P176B2R5G
VM3P175B2R5G
VM3P200B2R5G
VM3P206B2R5G
VM3P205B2R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4P150B2GLG
VM4P156B2GLG
VM4P155B2GLG
VM4P170B2GLG
VM4P176B2GLG
VM4P175B2GLG
VM4P200B2GLG
VM4P206B2GLG
VM4P205B2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4P150B2R1G
VM4P156B2R1G
VM4P155B2R1G
VM4P170B2R1G
VM4P176B2R1G
VM4P175B2R1G
VM4P200B2R1G
VM4P206B2R1G
VM4P205B2R1G
ENCLOSED
REFLECTOR
VM4P150B2ERN
VM4P156B2ERN
VM4P155B2ERN
VM4P170B2ERN
VM4P176B2ERN
VM4P175B2ERN
VM4P200B2ERN
VM4P206B2ERN
VM4P205B2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4P150B2R5G
VM4P156B2R5G
VM4P155B2R5G
VM4P170B2R5G
VM4P176B2R5G
VM4P175B2R5G
VM4P200B2R5G
VM4P206B2R5G
VM4P205B2R5G
1See hazardous application data on pages L108-L111 for limitations.
2Catalog numbers shown are with guard (except enclosed reflectors); to omit guard, change ending G to N; e.g. VM3P050X2GLN
3Catalog numbers shown are with 3/4" conduit openings, change 2 to 3 for 1"; e.g. VM3P150X3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
5-1/2" OPTIC THREAD SIZE 2
CERTILITE®V SERIES LIGHTING
METAL HALIDE PULSE, 150-200W MOGUL BASE HID L77
L
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
Cone
w/ 5-1/2"
Globe & Guard
Cone
w/ 7-3/4"
Globe & Guard
EZ Adapter
w/ 5-1/2"
Refractor & Guard
EZ Adapter
w/ 7-3/4"
Refractor & Guard
Cone
w/ Enclosed Reflector
WATTS
150
175
200
DESCRIPTION
ANSI
M102
M142
M137
M152
M136
HUB
SIZE3
3/4"
3/4"
3/4"
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3P150C2GLG
VM3P156C2GLG
VM3P155C2GLG
VM3P170C2GLG
VM3P176C2GLG
VM3P175C2GLG
VM3P200C2GLG
VM3P206C2GLG
VM3P205C2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3P150C2R1G
VM3P156C2R1G
VM3P155C2R1G
VM3P170C2R1G
VM3P176C2R1G
VM3P175C2R1G
VM3P200C2R1G
VM3P206C2R1G
VM3P205C2R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3P150C2R5G
VM3P156C2R5G
VM3P155C2R5G
VM3P170C2R5G
VM3P176C2R5G
VM3P175C2R5G
VM3P200C2R5G
VM3P206C2R5G
VM3P205C2R5G
GLOBE
& GUARD
VM4P150C2GLG
VM4P156C2GLG
VM4P155C2GLG
VM4P170C2GLG
VM4P176C2GLG
VM4P175C2GLG
VM4P200C2GLG
VM4P206C2GLG
VM4P205C2GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4P150C2R1G
VM4P156C2R1G
VM4P155C2R1G
VM4P170C2R1G
VM4P176C2R1G
VM4P175C2R1G
VM4P200C2R1G
VM4P206C2R1G
VM4P205C2R1G
ENCLOSED
REFLECTOR
VM4P150C2ERN
VM4P156C2ERN
VM4P155C2ERN
VM4P170C2ERN
VM4P176C2ERN
VM4P175C2ERN
VM4P200C2ERN
VM4P206C2ERN
VM4P205C2ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4P150C2R5G
VM4P156C2R5G
VM4P155C2R5G
VM4P170C2R5G
VM4P176C2R5G
VM4P175C2R5G
VM4P200C2R5G
VM4P206C2R5G
VM4P205C2R5G
VM 150-200 WATT METAL HALIDE PULSE EZ ADAPTER
WATTS
150
175
200
DESCRIPTION
ANSI
M102
M142
M137
M152
M136
HUB
SIZE6
6
6
6
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3P150EZGLG
VM3P156EZGLG
VM3P155EZGLG
VM3P170EZGLG
VM3P176EZGLG
VM3P175EZGLG
VM3P200EZGLG
VM3P206EZGLG
VM3P205EZGLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3P150EZR1G
VM3P156EZR1G
VM3P155EZR1G
VM3P170EZR1G
VM3P176EZR1G
VM3P175EZR1G
VM3P200EZR1G
VM3P206EZR1G
VM3P205EZR1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3P150EZR5G
VM3P156EZR5G
VM3P155EZR5G
VM3P170EZR5G
VM3P176EZR5G
VM3P175EZR5G
VM3P200EZR5G
VM3P206EZR5G
VM3P205EZR5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4P150EZGLG
VM4P156EZGLG
VM4P155EZGLG
VM4P170EZGLG
VM4P176EZGLG
VM4P175EZGLG
VM4P200EZGLG
VM4P206EZGLG
VM4P205EZGLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4P150EZR1G
VM4P156EZR1G
VM4P155EZR1G
VM4P170EZR1G
VM4P176EZR1G
VM4P175EZR1G
VM4P200EZR1G
VM4P206EZR1G
VM4P205EZR1G
ENCLOSED
REFLECTOR
VM4P150EZERN
VM4P156EZERN
VM4P155EZERN
VM4P170EZERN
VM4P176EZERN
VM4P175EZERN
VM4P200EZERN
VM4P206EZERN
VM4P205EZERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4P150EZR5G
VM4P156EZR5G
VM4P155EZR5G
VM4P170EZR5G
VM4P176EZR5G
VM4P175EZR5G
VM4P200EZR5G
VM4P206EZR5G
VM4P205EZR5G
1See hazardous application data on pages L108-L111 for limitations.
2Catalog numbers shown are with guard (except enclosed reflector); to omit guard change ending G to N; e.g. VM3P150C2GLN
3Catalog numbers shown are with 3/4" conduit openings; change 2 to 3 for 1"; e.g. VM3P150C3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
6VMEZA tank adapters UL “Classified” as an assembly for use between VM Tanks and EZ mounts. Order EZ mounts separately, see page L83.
VM 150-200 WATT METAL HALIDE PULSE CONE
7-3/4" OPTIC THREAD SIZE 2
CERTILITE®V SERIES LIGHTING
METAL HALIDE PULSE, 150-200W MOGUL BASE HID
L78
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
Stanchion 25°
w/ 5-1/2"
Globe & Guard
Stanchion 25°
w/ 7-3/4"
Globe & Guard
Stanchion Straight
w/ 5-1/2"
Refractor & Guard
Stanchion Straight
w/ 7-3/4"
Refractor & Guard
Stanchion 25°
w/ Enclosed Reflector
WATTS
150
175
200
DESCRIPTION
ANSI
M102
M142
M137
M152
M136
HUB
SIZE3
1-1/2"
1-1/2"
1-1/2"
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3P150D5GLG
VM3P156D5GLG
VM3P155D5GLG
VM3P170D5GLG
VM3P176D5GLG
VM3P175D5GLG
VM3P200D5GLG
VM3P206D5GLG
VM3P205D5GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3P150D5R1G
VM3P156D5R1G
VM3P155D5R1G
VM3P170D5R1G
VM3P176D5R1G
VM3P175D5R1G
VM3P200D5R1G
VM3P206D5R1G
VM3P205D5R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3P150D5R5G
VM3P156D5R5G
VM3P155D5R5G
VM3P170D5R5G
VM3P176D5R5G
VM3P175D5R5G
VM3P200D5R5G
VM3P206D5R5G
VM3P205D5R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4P150D5GLG
VM4P156D5GLG
VM4P155D5GLG
VM4P170D5GLG
VM4P176D5GLG
VM4P175D5GLG
VM4P200D5GLG
VM4P206D5GLG
VM4P205D5GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4P150D5R1G
VM4P156D5R1G
VM4P155D5R1G
VM4P170D5R1G
VM4P176D5R1G
VM4P175D5R1G
VM4P200D5R1G
VM4P206D5R1G
VM4P205D5R1G
ENCLOSED
REFLECTOR
VM4P150D5ERN
VM4P156D5ERN
VM4P155D5ERN
VM4P170D5ERN
VM4P176D5ERN
VM4P175D5ERN
VM4P200D5ERN
VM4P206D5ERN
VM4P205D5ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4P150D5R5G
VM4P156D5R5G
VM4P155D5R5G
VM4P170D5R5G
VM4P176D5R5G
VM4P175D5R5G
VM4P200D5R5G
VM4P206D5R5G
VM4P205D5R5G
VM 150-200 WATT METAL HALIDE PULSE STANCHION STRAIGHT
WATTS
150
175
200
DESCRIPTION
ANSI
M102
M142
M137
M152
M136
HUB
SIZE3
1-1/2"
1-1/2"
1-1/2"
VOLTAGE4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM3P150S5GLG
VM3P156S5GLG
VM3P155S5GLG
VM3P170S5GLG
VM3P176S5GLG
VM3P175S5GLG
VM3P200S5GLG
VM3P206S5GLG
VM3P205S5GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM3P150S5R1G
VM3P156S5R1G
VM3P155S5R1G
VM3P170S5R1G
VM3P176S5R1G
VM3P175S5R1G
VM3P200S5R1G
VM3P206S5R1G
VM3P205S5R1G
TYPE V GLASS
REFRACTOR
& GUARD
VM3P150S5R5G
VM3P156S5R5G
VM3P155S5R5G
VM3P170S5R5G
VM3P176S5R5G
VM3P175S5R5G
VM3P200S5R5G
VM3P206S5R5G
VM3P205S5R5G
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
VM4P150S5GLG
VM4P156S5GLG
VM4P155S5GLG
VM4P170S5GLG
VM4P176S5GLG
VM4P175S5GLG
VM4P200S5GLG
VM4P206S5GLG
VM4P205S5GLG
TYPE I GLASS
REFRACTOR
& GUARD
VM4P150S5R1G
VM4P156S5R1G
VM4P155S5R1G
VM4P170S5R1G
VM4P176S5R1G
VM4P175S5R1G
VM4P200S5R1G
VM4P206S5R1G
VM4P205S5R1G
ENCLOSED
REFLECTOR
VM4P150S5ERN
VM4P156S5ERN
VM4P155S5ERN
VM4P170S5ERN
VM4P176S5ERN
VM4P175S5ERN
VM4P200S5ERN
VM4P206S5ERN
VM4P205S5ERN
TYPE V GLASS
REFRACTOR
& GUARD
VM4P150S5R5G
VM4P156S5R5G
VM4P155S5R5G
VM4P170S5R5G
VM4P176S5R5G
VM4P175S5R5G
VM4P200S5R5G
VM4P206S5R5G
VM4P205S5R5G
1See hazardous application data on pages L108-L111 for limitations.
2Catalog numbers shown are with guard (except enclosed reflectors); to omit guard change ending G to N; e.g. VM3P150D5GLN
3Catalog numbers shown are with 1-1/2" conduit openings, change 5 to 4 for 1-1/4"; e.g. VM3P150D4GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
VM 150-200 WATT METAL HALIDE PULSE STANCHION 25° ANGLE
CERTILITE®V SERIES LIGHTING
VM5 CATALOG ORDERING LOGIC L79
L
CertiL i t e ®VCatalog Number Logic; 200-400 High Wattage (Mogul Base) HID Fixtures
Series Constant
Optic Thread Size
5—7 3/4"
Lamp Type
S—HPS (200, 250, 400, 600)
H—MH (250, 400)
P—MHP (Pulse Start 250, 320,
350, 400)
Voltage @ 60 Hertz
0—Quadri-Volt (120, 208, 240, 277)
5—480V
6—Tri - 120, 277, 347 (Canada)
7—220V
8—220/240 50 Hz
Mounting Type
A—Pendant
X—Ceiling
B—Wall Bracket
C—Cone Top
D—Stanchion 25°
S—Stanchion Straight 90°
E—EZ Mount Adapter1
N—None (mount ordered
separately)2
Lamp Wattage
20—200 (HPS)
25—250 (HPS, MHP)
32—320 (MHP)
35—350 (MHP)
40—400 (HPS, MH , MHP)
60—600 (HPS)
Guard
G—Globe Guard
N—No Guard6
Options
QA—Quartz Auxiliary7
BP—Ballast Protector 250-
400W HPS only
F1—Fusing 120V8
F2—Fusing 208V8
F3—Fusing 240V8
F4—Fusing 277V8
F5—Fusing 480V8
F6—Fusing 347V8
F7—Fusing 220V8
F8—Fusing 240V 50 Hz8
P1—Photocell 120V9
P2—Photocell 208-277V9
P3—Photocell 347V9
Q1—QD Wired to 120V
Q2—QD Wired to 208V
Q3—QD Wired to 240V
Q4—QD Wired to 277V
Q5—QD Wired to 480V
Q6—QD Wired to 347V
Q7—QD 220V
Q8—QD 240V (50Hz)
TBx—Terminal Blocks
x= Voltage Code
AS—Assembled Fixture with
Standard Lamp
AD—Assembled Fixture with
Dual-Arc-Tube Lamp 250,
400 HPS only
AN—Assembled, no lamp
CS—Component Pack with
Standard Lamp
CP—Component Pack-No
Lamp
Optic
GL—Globe
ER—Enclosed Reflector
EP—Poylcarbonate Shielded
Enclosed Reflector
S2—Type II Spin-Top Refractor
S5—Type V Spin-Top Refractor
FG—Silicone3Coated Globe
TG—Teflon®4Coated Globe
T2—Teflon®4Coated Type II
12" Spin-Top Refractor
TV—Teflon®4Coated Type V
12" Spin-Top Refractor
Entry (Mounts available)
2—3/4" NPT (A,B,C,X)
3—1" NPT (A,B,C,X)
4—1 1/4" NPT (D,S)
5—1 1/2" NPT (D,S)
6—3/4" NPT 5-Hub (X)
7—1" NPT 5-Hub (X)
8—M20 4-Hub (X)
9—M20 5-Hub (X)
Z—EZ Mount Adapter1
N—None (mount ordered
separately)2
VM 0 0 00 0 0 0 00 0 (NR5) 00
1Completes as “EZ”, conduit mounting boxes ordered separately -
See L83.
2NN mount ordered separately.
3Silicone coated globe for additional impact protection.
4Teflon®is a registered trademark of DuPont, Inc.
5Restricted Breathing - See L54 for more information.
6Order Guards for Spin-Tops & VMER40 separately.
Consult factory for available lamp and voltage combinations.
7QA not suitable for Class I, Div. 2/Zone 2 applications; consult factory
for other hazardous applications.
8Fusing not for Marine or Canadian installations.
9Photo cells for Class I, Div. 2 only, or C1Z2 nR , not Class II.
Field connection to proper tap in case of Multitap Ballasts.
Not for use with wall or straight (90°) Stanchion.
QD = Quick Disconnect. Allows easy tank removal for maintenance.
Electrician simply unplugs de-energized ballast from supply circuit.
400W M59 fixtures and EXPORT ONLY (EISA LAW).
®
11
11
12
13
V
12
12
13
CERTILITE®V SERIES LIGHTING
HIGH PRESSURE SODIUM, 200-600W MOGUL BASE HID
L80
Pendant
w/ Globe &
Guard
Pendant
w/ Spin-Top
Refractor
Ceiling
w/ Enclosed
Reflector
VM 200-600 WATT HIGH PRESSURE SODIUM PENDANT
WATTS
200
250
400
600
DESCRIPTION
ANSI
S66
S50
S51
S106
HUB
SIZE 3
3/4"
3/4"
3/4"
3/4"
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5S200A2GLG
VM5S206A2GLG
VM5S205A2GLG
VM5S250A2GLG
VM5S256A2GLG
VM5S255A2GLG
VM5S400A2GLG
VM5S406A2GLG
VM5S405A2GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5S200A2S5N
VM5S206A2S5N
VM5S205A2S5N
VM5S250A2S5N
VM5S256A2S5N
VM5S255A2S5N
VM5S400A2S5N
VM5S406A2S5N
VM5S405A2S5N
ENCLOSED
REFLECTOR
VM5S200A2ERN
VM5S206A2ERN
VM5S205A2ERN
VM5S250A2ERN
VM5S256A2ERN
VM5S255A2ERN
VM5S400A2ERN
VM5S406A2ERN
VM5S405A2ERN
VM5S600A2ERN
VM5S606A2ERN
VM5S605A2ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
VM5S200A2EPN
VM5S206A2EPN
VM5S205A2EPN
VM5S250A2EPN
VM5S256A2EPN
VM5S255A2EPN
VM5S400A2EPN
VM5S406A2EPN
VM5S405A2EPN
1See hazardous application data on pages L112-L113 for limitations.
2Globe catalog number shown with guard. To omit guard, change G to N; e.g. VM5S200A2GLN. Order spin top and enclosed reflec-
tor guards separately.
3Catalog numbers shown are with 3/4" conduit openings, change 2 to 3 for 1"; e.g. VM5S200A3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
VM 200-600 WATT HIGH PRESSURE SODIUM CEILING
WATTS
200
250
400
600
DESCRIPTION
ANSI
S66
S50
S51
S106
HUB
SIZE 3
3/4"
3/4"
3/4"
3/4"
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5S200X2GLG
VM5S206X2GLG
VM5S205X2GLG
VM5S250X2GLG
VM5S256X2GLG
VM5S255X2GLG
VM5S400X2GLG
VM5S406X2GLG
VM5S405X2GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5S200X2S5N
VM5S206X2S5N
VM5S205X2S5N
VM5S250X2S5N
VM5S256X2S5N
VM5S255X2S5N
VM5S400X2S5N
VM5S406X2S5N
VM5S405X2S5N
ENCLOSED
REFLECTOR
VM5S200X2ERN
VM5S206X2ERN
VM5S205X2ERN
VM5S250X2ERN
VM5S256X2ERN
VM5S255X2ERN
VM5S400X2ERN
VM5S406X2ERN
VM5S405X2ERN
VM5S600X2ERN
VM5S606X2ERN
VM5S605X2ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
VM5S200X2EPN
VM5S206X2EPN
VM5S205X2EPN
VM5S250X2EPN
VM5S256X2EPN
VM5S255X2EPN
VM5S400X2EPN
VM5S406X2EPN
VM5S405X2EPN
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
CERTILITE®V SERIES LIGHTING
HIGH PRESSURE SODIUM, 200-600W MOGUL BASE HID L81
L
Wall
w/ Globe &
Guard
Wall
w/ Spin-Top
Refractor
Cone
w/ Enclosed
Reflector
VM 200-600 WATT HIGH PRESSURE SODIUM WALL
WATTS
200
250
400
600
DESCRIPTION
ANSI
S66
S50
S51
S106
HUB
SIZE 3
3/4"
3/4"
3/4"
3/4"
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5S200B2GLG
VM5S206B2GLG
VM5S205B2GLG
VM5S250B2GLG
VM5S256B2GLG
VM5S255B2GLG
VM5S400B2GLG
VM5S406B2GLG
VM5S405B2GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5S200B2S5N
VM5S206B2S5N
VM5S205B2S5N
VM5S250B2S5N
VM5S256B2S5N
VM5S255B2S5N
VM5S400B2S5N
VM5S406B2S5N
VM5S405B2S5N
ENCLOSED
REFLECTOR
VM5S200B2ERN
VM5S206B2ERN
VM5S205B2ERN
VM5S250B2ERN
VM5S256B2ERN
VM5S255B2ERN
VM5S400B2ERN
VM5S406B2ERN
VM5S405B2ERN
VM5S600B2ERN
VM5S606B2ERN
VM5S605B2ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
1See hazardous application data on pages L112-L113 for limitations.
2Globe catalog number shown with guard. To omit guard, change G to N; e.g. VM5S200B2GLN. Order spin top and enclosed
reflector guards separately.
3Catalog numbers shown are with 3/4" conduit openings, change 2 to 3 for 1"; e.g. VM5S200B3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
VM 200-600 WATT HIGH PRESSURE SODIUM CONE
WATTS
200
250
400
600
DESCRIPTION
ANSI
S66
S50
S51
S106
HUB
SIZE 3
3/4"
3/4"
3/4"
3/4"
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5S200C2GLG
VM5S206C2GLG
VM5S205C2GLG
VM5S250C2GLG
VM5S256C2GLG
VM5S255C2GLG
VM5S400C2GLG
VM5S406C2GLG
VM5S405C2GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5S200C2S5N
VM5S206C2S5N
VM5S205C2S5N
VM5S250C2S5N
VM5S256C2S5N
VM5S255C2S5N
VM5S400C2S5N
VM5S406C2S5N
VM5S405C2S5N
ENCLOSED
REFLECTOR
VM5S200C2ERN
VM5S206C2ERN
VM5S205C2ERN
VM5S250C2ERN
VM5S256C2ERN
VM5S255C2ERN
VM5S400C2ERN
VM5S406C2ERN
VM5S405C2ERN
VM5S600C2ERN
VM5S606C2ERN
VM5S605C2ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
VM5S200C2EPN
VM5S206C2EPN
VM5S205C2EPN
VM5S250C2EPN
VM5S256C2EPN
VM5S255C2EPN
VM5S400C2EPN
VM5S406C2EPN
VM5S405C2EPN
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
CERTILITE®V SERIES LIGHTING
HIGH PRESSURE SODIUM, 200-600W MOGUL BASE HID
L82
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
Stanchion 25°
w/ Globe &
Guard
Stanchion 25°
w/ Spin-Top
Refractor
Stanchion Straight
w/ Enclosed
Reflector
VM 200-600 WATT HIGH PRESSURE SODIUM STANCHION 25° ANGLE
WATTS
200
250
400
600
DESCRIPTION
ANSI
S66
S50
S51
S106
HUB
SIZE 3
1-1/2"
1-1/2"
1-1/2"
1-1/2"
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5S200D5GLG
VM5S206D5GLG
VM5S205D5GLG
VM5S250D5GLG
VM5S256D5GLG
VM5S255D5GLG
VM5S400D5GLG
VM5S406D5GLG
VM5S405D5GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5S200D5S5N
VM5S206D5S5N
VM5S205D5S5N
VM5S250D5S5N
VM5S256D5S5N
VM5S255D5S5N
VM5S400D5S5N
VM5S406D5S5N
VM5S405D5S5N
ENCLOSED
REFLECTOR
VM5S200D5ERN
VM5S206D5ERN
VM5S205D5ERN
VM5S250D5ERN
VM5S256D5ERN
VM5S255D5ERN
VM5S400D5ERN
VM5S406D5ERN
VM5S405D5ERN
VM5S600D5ERN
VM5S606D5ERN
VM5S605D5ERN
1See hazardous application data on pages L112-L113 for limitations.
2Globe catalog number shown with guard. To omit guard, change G to N; e.g. VM5S200D5GLN. Order
spin top and enclosed reflector guards separately.
3Catalog numbers shown are with 1-1/2" conduit openings, change 5 to 4 for 1-1/4"; e.g. VM5S200D4GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
VM 200-600 WATT HIGH PRESSURE SODIUM STANCHION STRAIGHT
WATTS
200
250
400
600
DESCRIPTION
ANSI
S66
S50
S51
S106
HUB
SIZE3
1-1/2"
1-1/2"
1-1/2"
1-1/2"
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5S200S5GLG
VM5S206S5GLG
VM5S205S5GLG
VM5S250S5GLG
VM5S256S5GLG
VM5S255S5GLG
VM5S400S5GLG
VM5S406S5GLG
VM5S405S5GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5S200S5S5N
VM5S206S5S5N
VM5S205S5S5N
VM5S250S5S5N
VM5S256S5S5N
VM5S255S5S5N
VM5S400S5S5N
VM5S406S5S5N
VM5S405S5S5N
ENCLOSED
REFLECTOR
VM5S200S5ERN
VM5S206S5ERN
VM5S205S5ERN
VM5S250S5ERN
VM5S256S5ERN
VM5S255S5ERN
VM5S400S5ERN
VM5S406S5ERN
VM5S405S5ERN
VM5S600S5ERN
VM5S606S5ERN
VM5S605S5ERN
CERTILITE®V SERIES LIGHTING
HIGH PRESSURE SODIUM, 200-600W MOGUL BASE HID L83
L
EZ Adapter
w/ Globe &
Guard
EZ Adapter
w/ Spin-Top
Refractor
EZ Adapter
w/ Enclosed
Reflector
VM 200-600 WATT HIGH PRESSURE SODIUM EZ ADAPTER
WATTS
200
250
400
600
DESCRIPTION
ANSI
S66
S50
S51
S106
HUB
SIZE 3
3
3
3
3
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5S200EZGLG
VM5S206EZGLG
VM5S205EZGLG
VM5S250EZGLG
VM5S256EZGLG
VM5S255EZGLG
VM5S400EZGLG
VM5S406EZGLG
VM5S405EZGLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5S200EZS5N
VM5S206EZS5N
VM5S205EZS5N
VM5S250EZS5N
VM5S256EZS5N
VM5S255EZS5N
VM5S400EZS5N
VM5S406EZS5N
VM5S405EZS5N
ENCLOSED
REFLECTOR
VM5S200EZERN
VM5S206EZERN
VM5S205EZERN
VM5S250EZERN
VM5S256EZERN
VM5S255EZERN
VM5S400EZERN
VM5S406EZERN
VM5S405EZERN
VM5S600EZERN
VM5S606EZERN
VM5S605EZERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR6
VM5S200EZEPN
VM5S206EZEPN
VM5S205EZEPN
VM5S250EZEPN
VM5S256EZEPN
VM5S255EZEPN
VM5S400EZEPN
VM5S406EZEPN
VM5S405EZEPN
1See hazardous application data on pages L112-L113 for limitations.
2Globe catalog number shown with guard. To omit guard, change G to N; e.g. VM5S200EZGLN. Order spin top and enclosed
reflector guards separately.
3VMEZA tank adapters UL “classified” as an assembly for use between VM tanks and EZ mounts. See above for separate
ordering information
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
6VMEP40 not for use with EZ wall bracket.
HUB SIZE
3/4"
1"
1-1/4"/1-1/2"*
CATALOG NUMBER
PENDANT CEILING BRACKET STANCHION
EZA2 EZX2 EZB2
EZA3 EZX3 EZB3
—— — EZD4A*
MOUNTING BOXES
Wall Bracket 25° Stanchion
Pendant Ceiling
*1-1/2" furnished with 1-1/2"-1-1/4" reducer and extension. Extension only part number EZDVMA.
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
CERTILITE®V SERIES LIGHTING
METAL HALIDE PULSE, 400W MOGUL BASE HID
L84
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
Pendant
w/ Globe &
Guard
Ceiling
w/ Globe &
Guard
Wall
w/ Spin-Top
Refractor
VM 400 WATT METAL HALIDE PENDANT
WATTS
400
6
DESCRIPTION
ANSI
M59
HUB
SIZE 3
3/4"
VOLTAGE 4
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5H400A2GLG
VM5H406A2GLG
VM5H405A2GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5H400A2S5N
VM5H406A2S5N
VM5H405A2S5N
ENCLOSED
REFLECTOR
VM5H400A2ERN
VM5H406A2ERN
VM5H405A2ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
VM5H400A2EPN
VM5H406A2EPN
VM5H405A2EPN
1See hazardous application data on pages L112-L113 for limitations.
2Globe catalog number shown with guard. To omit guard, change G to N; e.g. VM5H400A2GLN. Order spin top and enclosed
reflector guards separately.
3Catalog numbers shown are with 3/4" conduit openings, change 2 to 3 for 1"; e.g. VM5H400A3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
6400W M59 Fixtures are EXPORT ONLY (EISA LAW).
Cone
w/ Enclosed
Reflector
VM 400 WATT METAL HALIDE CEILING
WATTS
400
6
DESCRIPTION
ANSI
M59
HUB
SIZE 3
3/4"
VOLTAGE 4
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5H400X2GLG
VM5H406X2GLG
VM5H405X2GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5H400X2S5N
VM5H406X2S5N
VM5H405X2S5N
ENCLOSED
REFLECTOR
VM5H400X2ERN
VM5H406X2ERN
VM5H405X2ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
VM5H400X2EPN
VM5H406X2EPN
VM5H405X2EPN
V M 4 0 0 W AT T M E T A L H A L I D E W A L L
WATTS
400
6
DESCRIPTION
ANSI
M59
HUB
SIZE 3
3/4"
VOLTAGE4
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5H400B2GLG
VM5H406B2GLG
VM5H405B2GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5H400B2S5N
VM5H406B2S5N
VM5H405B2S5N
ENCLOSED
REFLECTOR
VM5H400B2ERN
VM5H406B2ERN
VM5H405B2ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
VM 400 WATT METAL HALIDE CONE
WATTS
400
6
DESCRIPTION
ANSI
M59
HUB
SIZE 3
3/4"
VOLTAGE 4
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5H400C2GLG
VM5H406C2GLG
VM5H405C2GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5H400C2S5N
VM5H406C2S5N
VM5H405C2S5N
ENCLOSED
REFLECTOR
VM5H400C2ERN
VM5H406C2ERN
VM5H405C2ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
VM5H400C2EPN
VM5H406C2EPN
VM5H405C2EPN
1See hazardous application data on pages L112-L113 for limitations.
2Globe catalog number shown with guard. To omit guard, change G to N; e.g. VM5H400D5GLN. Order spin top and enclosed
reflector guards separately.
3Catalog numbers shown with 1-1/2" conduit openings; change 5 to 4 for 1-1/4"; e.g. VM5H400D4GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
6400W M59 Fixtures are EXPORT ONLY (EISA LAW).
7VMEZA tank adapters UL “classified” as an assembly for use between VM tanks and EZ mounts. Order EZ mounts separately.
See page L83.
8VMEP40 not for use with EZ wall bracket.
CERTILITE®V SERIES LIGHTING
METAL HALIDE PULSE, 400W MOGUL BASE HID L85
L
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
Stanchion 25°
w/ Globe &
Guard
Stanchion 90°
w/ Spin-Top
Refractor
VM 400 WATT METAL HALIDE STANCHION 25° ANGLE
WATTS
400
6
DESCRIPTION
ANSI
M59
HUB
SIZE 3
1-1/2"
VOLTAGE 4
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5H400D5GLG
VM5H406D5GLG
VM5H405D5GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5H400D5S5N
VM5H406D5S5N
VM5H405D5S5N
ENCLOSED
REFLECTOR
VM5H400D5ERN
VM5H406D5ERN
VM5H405D5ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
EZ Adapter
w/ Enclosed
Reflector
VM 400 WATT METAL HALIDE STANCHION STRAIGHT
WATTS
400
6
DESCRIPTION
ANSI
M59
HUB
SIZE 3
1-1/2"
VOLTAGE 4
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5H400S5GLG
VM5H406S5GLG
VM5H405S5GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5H400S5S5N
VM5H406S5S5N
VM5H405S5S5N
ENCLOSED
REFLECTOR
VM5H400S5ERN
VM5H406S5ERN
VM5H405S5ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
VM 400 WATT METAL HALIDE EZ ADAPTER
WATTS
400
6
DESCRIPTION
ANSI
M59
HUB
SIZE 7
7
VOLTAGE 4
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5H400EZGLG
VM5H406EZGLG
VM5H405EZGLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5H400EZS5N
VM5H406EZS5N
VM5H405EZS5N
ENCLOSED
REFLECTOR
VM5H400EZERN
VM5H406EZERN
VM5H405EZERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR8
VM5H400EZEPN
VM5H406EZEPN
VM5H405EZEPN
L86 CERTILITE®V SERIES LIGHTING
METAL HALIDE PULSE, 400W MOGUL BASE HID
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
VM 250-400 WATT METAL HALIDE PULSE PENDANT
WATTS
250
320
350
400
DESCRIPTION
ANSI
M138
M153
M132
M154
M131
M135
M155
HUB
SIZE 3
3/4"
3/4"
3/4"
3/4"
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5P250A2GLG
VM5P256A2GLG
VM5P255A2GLG
VM5P320A2GLG
VM5P326A2GLG
VM5P325A2GLG
VM5P350A2GLG
VM5P356A2GLG
VM5P355A2GLG
VM5P400A2GLG
VM5P406A2GLG
VM5P405A2GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5P250A2S5N
VM5P256A2S5N
VM5P255A2S5N
VM5P320A2S5N
VM5P326A2S5N
VM5P325A2S5N
VM5P350A2S5N
VM5P356A2S5N
VM5P355A2S5N
VM5P400A2S5N
VM5P406A2S5N
VM5P405A2S5N
ENCLOSED
REFLECTOR
VM5P250A2ERN
VM5P256A2ERN
VM5P255A2ERN
VM5P320A2ERN
VM5P326A2ERN
VM5P325A2ERN
VM5P350A2ERN
VM5P356A2ERN
VM5P355A2ERN
VM5P400A2ERN
VM5P406A2ERN
VM5P405A2ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
VM5P250A2EPN
VM5P256A2EPN
VM5P255A2EPN
VM5P320A2EPN
VM5P326A2EPN
VM5P325A2EPN
VM5P350A2EPN
VM5P356A2EPN
VM5P355A2EPN
VM5P400A2EPN
VM5P406A2EPN
VM5P405A2EPN
VM 250-400 WATT METAL HALIDE PULSE CEILING
WATTS
250
320
350
400
DESCRIPTION
ANSI
M138
M153
M132
M154
M131
M135
M155
HUB
SIZE 3
3/4"
3/4"
3/4"
3/4"
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5P250X2GLG
VM5P256X2GLG
VM5P255X2GLG
VM5P320X2GLG
VM5P326X2GLG
VM5P325X2GLG
VM5P350X2GLG
VM5P356X2GLG
VM5P355X2GLG
VM5P400X2GLG
VM5P406X2GLG
VM5P405X2GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5P250X2S5N
VM5P256X2S5N
VM5P255X2S5N
VM5P320X2S5N
VM5P326X2S5N
VM5P325X2S5N
VM5P350X2S5N
VM5P356X2S5N
VM5P355X2S5N
VM5P400X2S5N
VM5P406X2S5N
VM5P405X2S5N
ENCLOSED
REFLECTOR
VM5P250X2ERN
VM5P256X2ERN
VM5P255X2ERN
VM5P320X2ERN
VM5P326X2ERN
VM5P325X2ERN
VM5P350X2ERN
VM5P356X2ERN
VM5P355X2ERN
VM5P400X2ERN
VM5P406X2ERN
VM5P405X2ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
VM5P250X2EPN
VM5P256X2EPN
VM5P255X2EPN
VM5P320X2EPN
VM5P326X2EPN
VM5P325X2EPN
VM5P350X2EPN
VM5P356X2EPN
VM5P355X2EPN
VM5P400X2EPN
VM5P406X2EPN
VM5P405X2EPN
1See hazardous application data on pages L112-L113 for limitations.
2Globe catalog number shown with guard. To omit guard, change G to N; e.g. VM5P250A2GLN. Order spin top and enclosed
reflector guards separately.
3Catalog numbers shown are with 3/4" conduit openings, change 2 to 3 for 1"; e.g. VM5P250A3GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
Pendant
w/ Globe &
Guard
Pendant
w/ Spin-Top
Refractor
Ceiling
w/ Enclosed
Reflector
L87
CERTILITE®V SERIES LIGHTING
METAL HALIDE PULSE, 400W MOGUL BASE HID
L
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
VM 250-400 WATT METAL HALIDE PULSE WALL
WATTS
250
320
350
400
DESCRIPTION
ANSI
M138
M153
M132
M154
M131
M135
M155
HUB
SIZE 3
3/4"
3/4"
3/4"
3/4"
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5P250B2GLG
VM5P256B2GLG
VM5P255B2GLG
VM5P320B2GLG
VM5P326B2GLG
VM5P325B2GLG
VM5P350B2GLG
VM5P356B2GLG
VM5P355B2GLG
VM5P400B2GLG
VM5P406B2GLG
VM5P405B2GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5P250B2S5N
VM5P256B2S5N
VM5P255B2S5N
VM5P320B2S5N
VM5P326B2S5N
VM5P325B2S5N
VM5P350B2S5N
VM5P356B2S5N
VM5P355B2S5N
VM5P400B2S5N
VM5P406B2S5N
VM5P405B2S5N
ENCLOSED
REFLECTOR
VM5P250B2ERN
VM5P256B2ERN
VM5P255B2ERN
VM5P320B2ERN
VM5P326B2ERN
VM5P325B2ERN
VM5P350B2ERN
VM5P356B2ERN
VM5P355B2ERN
VM5P400B2ERN
VM5P406B2ERN
VM5P405B2ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
VM 250-400 WATT METAL HALIDE PULSE CONE
WATTS
250
320
350
400
DESCRIPTION
ANSI
M138
M153
M132
M154
M131
M135
M155
HUB
SIZE 3
3/4"
3/4"
3/4"
3/4"
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5P250C2GLG
VM5P256C2GLG
VM5P255C2GLG
VM5P320C2GLG
VM5P326C2GLG
VM5P325C2GLG
VM5P350C2GLG
VM5P356C2GLG
VM5P355C2GLG
VM5P400C2GLG
VM5P406C2GLG
VM5P405C2GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5P250C2S5N
VM5P256C2S5N
VM5P255C2S5N
VM5P320C2S5N
VM5P326C2S5N
VM5P325C2S5N
VM5P350C2S5N
VM5P356C2S5N
VM5P355C2S5N
VM5P400C2S5N
VM5P406C2S5N
VM5P405C2S5N
ENCLOSED
REFLECTOR
VM5P250C2ERN
VM5P256C2ERN
VM5P255C2ERN
VM5P320C2ERN
VM5P326C2ERN
VM5P325C2ERN
VM5P350C2ERN
VM5P356C2ERN
VM5P355C2ERN
VM5P400C2ERN
VM5P406C2ERN
VM5P405C2ERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR
VM5P250C2EPN
VM5P256C2EPN
VM5P255C2EPN
VM5P320C2EPN
VM5P326C2EPN
VM5P325C2EPN
VM5P350C2EPN
VM5P356C2EPN
VM5P355C2EPN
VM5P400C2EPN
VM5P406C2EPN
VM5P405C2EPN
1See hazardous application data on pages L112-L113 for limitations.
2Globe catalog number shown with guard. To omit guard, change G to N; e.g. VM5P250B2GLN. Order spin top and enclosed
reflector guards separately.
3Catalog numbers shown are with 3/4" conduit openings, change 2 to 3 for 1"; e.g. VM5P250B3GLG.
4Consult catalog logic for other available voltages.
4Add suffix NR for restricted breathing; see page L54 for more information.
Wall
w/ Globe &
Guard
Wall
w/ Spin-Top
Refractor
Cone
w/ Enclosed
Reflector
CERTILITE®V SERIES LIGHTING
METAL HALIDE PULSE, 250-400W MOGUL BASE HID
L88
VM 250-400 WATT METAL HALIDE PULSE STANCHION 25° ANGLE
WATTS
250
320
350
400
DESCRIPTION
ANSI
M138
M153
M132
M154
M131
M135
M155
HUB
SIZE 3
1-1/2"
1-1/2"
1-1/2"
1-1/2"
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5P250D5GLG
VM5P256D5GLG
VM5P255D5GLG
VM5P320D5GLG
VM5P326D5GLG
VM5P325D5GLG
VM5P350D5GLG
VM5P356D5GLG
VM5P355D5GLG
VM5P400D5GLG
VM5P406D5GLG
VM5P405D5GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5P250D5S5N
VM5P256D5S5N
VM5P255D5S5N
VM5P320D5S5N
VM5P326D5S5N
VM5P325D5S5N
VM5P350D5S5N
VM5P356D5S5N
VM5P355D5S5N
VM5P400D5S5N
VM5P406D5S5N
VM5P405D5S5N
ENCLOSED
REFLECTOR
VM5P250D5ERN
VM5P256D5ERN
VM5P255D5ERN
VM5P320D5ERN
VM5P326D5ERN
VM5P325D5ERN
VM5P350D5ERN
VM5P356D5ERN
VM5P355D5ERN
VM5P400D5ERN
VM5P406D5ERN
VM5P405D5ERN
VM 250-400 WATT METAL HALIDE PULSE STANCHION STRAIGHT
WATTS
250
320
350
400
DESCRIPTION
ANSI
M138
M153
M132
M154
M131
M135
M155
HUB
SIZE 3
1-1/2"
1-1/2"
1-1/2"
1-1/2"
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5P250S5GLG
VM5P256S5GLG
VM5P255S5GLG
VM5P320S5GLG
VM5P326S5GLG
VM5P325S5GLG
VM5P350S5GLG
VM5P356S5GLG
VM5P355S5GLG
VM5P400S5GLG
VM5P406S5GLG
VM5P405S5GLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5P250S5S5N
VM5P256S5S5N
VM5P255S5S5N
VM5P320S5S5N
VM5P326S5S5N
VM5P325S5S5N
VM5P350S5S5N
VM5P356S5S5N
VM5P355S5S5N
VM5P400S5S5N
VM5P406S5S5N
VM5P405S5S5N
ENCLOSED
REFLECTOR
VM5P250S5ERN
VM5P256S5ERN
VM5P255S5ERN
VM5P320S5ERN
VM5P326S5ERN
VM5P325S5ERN
VM5P350S5ERN
VM5P356S5ERN
VM5P355S5ERN
VM5P400S5ERN
VM5P406S5ERN
VM5P405S5ERN
1See hazardous application data on pages L112-L113 for limitations.
2Globe catalog number shown with guard. To omit guard, change G to N; e.g. VM5P250D5GLN. Order spin
top and enclosed reflector guards separately.
3Catalog numbers shown with 1-1/2" conduit openings; change 5 to 4 for 1-1/4"; e.g. VM5P250D4GLG.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
Stanchion 25°
w/ Globe &
Guard
Stanchion 25°
w/ Spin-Top
Refractor
Stanchion Straight
w/ Enclosed
Reflector
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
CERTILITE®V SERIES LIGHTING
METAL HALIDE PULSE, 250-400W MOGUL BASE HID L89
L
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4X; IP66
NR Restricted Breathing Option5
Class I, Zone 2 AEx nAnR
Class I, Zone 2 Ex nR
Listed - File E10514 (Hazardous & Marine)
Certified - File LR11713
VM 250-400 WATT METAL HALIDE PULSE EZ ADAPTER
WATTS
250
320
350
400
DESCRIPTION
ANSI
M138
M153
M132
M154
M131
M135
M155
HUB
SIZE 3
3
3
3
3
VOLTAGE 4
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
Quad
Tri
480
7-3/4" OPTIC THREAD SIZE2
GLOBE
& GUARD
VM5P250EZGLG
VM5P256EZGLG
VM5P255EZGLG
VM5P320EZGLG
VM5P326EZGLG
VM5P325EZGLG
VM5P350EZGLG
VM5P356EZGLG
VM5P355EZGLG
VM5P400EZGLG
VM5P406EZGLG
VM5P405EZGLG
TYPE V
SPIN-TOP GLASS
REFRACTOR
VM5P250EZS5N
VM5P256EZS5N
VM5P255EZS5N
VM5P320EZS5N
VM5P326EZS5N
VM5P325EZS5N
VM5P350EZS5N
VM5P356EZS5N
VM5P355EZS5N
VM5P400EZS5N
VM5P406EZS5N
VM5P405EZS5N
ENCLOSED
REFLECTOR
VM5P250EZERN
VM5P256EZERN
VM5P255EZERN
VM5P320EZERN
VM5P326EZERN
VM5P325EZERN
VM5P350EZERN
VM5P356EZERN
VM5P355EZERN
VM5P400EZERN
VM5P406EZERN
VM5P405EZERN
POLYCARBONATE
SHIELDED
ENCLOSED REFLECTOR6
VM5P250EZEPN
VM5P256EZEPN
VM5P255EZEPN
VM5P320EZEPN
VM5P326EZEPN
VM5P325EZEPN
VM5P350EZEPN
VM5P356EZEPN
VM5P355EZEPN
VM5P400EZEPN
VM5P406EZEPN
VM5P405EZEPN
1See hazardous application data on pages L112-L113 for limitations.
2Globe catalog number shown with guard. To omit guard, change G to N; e.g. VM5P250EZGLN.
Order spin top and enclosed reflector guards separately.
3VMEZA tank adapters UL “classified” as an assembly for use between VM tanks and EZ mounts.
See above for separate ordering information.
4Consult catalog logic for other available voltages.
5Add suffix NR for restricted breathing; see page L54 for more information.
6VMEP40 not for use with EZ wall bracket.
HUB SIZE
3/4"
1"
1-1/4"/1-1/2"*
CATALOG NUMBER
PENDANT CEILING BRACKET STANCHION
EZA2 EZX2 EZB2
EZA3 EZX3 EZB3
—— — EZD4A*
MOUNTING BOXES
Wall Bracket 25° Stanchion
Pendant Ceiling
*1-1/2" furnished with 1-1/2"-1-1/4" reducer and extension. Extension only part number EZDVMA.
EZ Adapter
w/ Globe &
Guard
EZ Adapter
w/ Spin-Top
Refractor
EZ Adapter
w/ Enclosed
Reflector
CERTILITE®V SERIES LIGHTING
QL INDUCTION, 55/85/165W
L90
CERTILITE®V LUMINAIRE WITH INDUCTION LIGHTING SYSTEM
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4x
A = Lamp
B = Power Coupler
C = HF generator
A
C
B
Listed - File LR11713
CertiL i t e ®VCatalog Number Logic; 85-165W QL Induction Fixtures
Series Constant
Optic Thread Size
1—5 1/2" Reduced Profile 55W
4—7 3/4" Medium Tank 85W
5—7 3/4" Large Tank 165W
Lamp Type
Q—QL Induction
Voltage @ 60 Hertz
1—120V (60 HZ)
32—200-277V (50/60 HZ)
Mounting Type
A—Pendant
X—Ceiling
B—Wall Bracket
C—Cone Top
D—Stanchion 25°
S—Stanchion 90°
E—EZ Mount Adapter4
N—None (mount ordered
separately)5
Lamp Wattage
05—55W (VM1)
08—85W (VM4)
16—165W (VM5)9
Guard
G—Guard (Globes & Glass
refractors)
N—No Guard3
Options
P1—Photocell 120V
P2—Photocell 208-277V
Optic
GL—Globe9
R1—Type I Glass Refractor
R3—Type III Glass Refractor
R5—Type V Glass Refractor
S2—Type II 12" Spin-Top Refractor
S5—Type V 12" Spin-Top Refractor
ER—Enclosed Reflector
EP—Poylcarbonate Shielded
Enclosed Reflector6
Entry (Mounts available)
2—3/4" NPT (A,B,C,X)
3—1" NPT (A,B,C,X)
4—1 1/4" NPT (D,S)
5—1 1/2" NPT (D,S)
6—3/4" NPT 5-Hub (X)
7—1" NPT 5-Hub (X)
8—M20 4-Hub (X)
9—M20 5-Hub (X)
Z—EZ Mount Adapter4
N—None (mount ordered
separately)5
VM 0 0 00 0 0 0 00 0 00
1See hazardous application data on pages L108-L111 for limitations.
2Must not exceed 40OC ambient.
3Order Guards for Spin-Tops & VMER40 separately.
4Completes as “EZ”, conduit mounts ordered separately - See L83.
5NN mount ordered separately.
6Not for use with wall or straight (90°) stanchion.
7At 100 hours; up to 75% of nominal value maintained at 60,000 hours.
8Lumens per watt.
9165W uses VMG25 in VM5 tank (or VMR25x all glass refractors).
APPLICATIONS
Where long life lamp sources (up to 100,000 hours) 2are need-
ed.
In areas that require “instant on” illumination.
Where cool globe temperatures are required.
In dificult-to-reach installations.
In cold environment applications.
Philips®is a registered trademark of Koninklijke Philips Electronics N.V.
F E AT U R E S
Almost maintenance-free Philips®QL Induction Lamp system.
Includes lamp.
Up to 100,000 hour life minimizes maintenance costs.
Instant start and restart in low temperatures down to -40°C.
White light with 80+ CRI (Color rendering Index).
High lumen output & efficacy.
Less than 10% THD (Total Hamonic Distortion) will not add
electrical noise to circuits.
QL SIZE INITIAL LUMENS NOMINAL LUMENS7EFFICACY8
55 WATT 3800 3500 63.5
85 WATT 6500 6000 70
165 WATT 12500 12000 72.5
CERTILITE®V SERIES LIGHTING
QL INDUCTION, 55/85/165W L91
L
1See hazardous application data on pages L108-L111 for limitations.
2Globe catalog number shown with guard. To omit guard, change G to N; e.g. VM4Q081A2GLN. Order spin top and enclosed
reflector guards separately.
3Catalog numbers shown are with 3/4" conduit openings, change 2 to 3 for 1"; e.g. VM4Q081A3GLG.
Pendant
w/ Globe &
Guard
Ceiling
w/ Globe &
Guard
Wall
w/ Spin-Top
Refractor
Cone
w/ Enclosed
Reflector
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4x
Listed - File LR11713
VM 55-165W QL INDUCTION PENDANT2(INCLUDES LAMP)
DESCRIPTION
HUB
SIZE3
TANK
STYLEVOLTAGE
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
ENCLOSED
REFRACTOR
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
55 3/4" 120 VM1 VM1Q051A2GLG VM1Q051A2R5G ——
200-277 VM1Q0532A2GLG VM1Q0532A2R5G ——
85 3/4" 120 VM4 ——VM4Q081A2GLG VM4Q081A2R5G VM4Q081A2ERN
200-277 ——VM4Q0832A2GLG VM4Q0832A2R5G VM4Q0832A2ERN
165 3/4" 120 VM5 VM5Q161A2GLG VM5Q161A2R5G VM5Q161A2ERN
200-277 ——VM5Q1632A2GLG VM5Q1632B2R5G VM5Q1632A2ERN
VM 55-165W QL INDUCTION CEILING2(INCLUDES LAMP)
DESCRIPTION
HUB
SIZE3
TANK
STYLEVOLTAGE
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
ENCLOSED
REFRACTOR
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
55 3/4" 120 VM1 VM1Q051X2GLG VM1Q051X2R5G ——
200-277 VM1Q0532X2GLG VM1Q0532X2R5G ——
85 3/4" 120 VM4 ——VM4Q081X2GLG VM4Q081X2R5G VM4Q081X2ERN
200-277 ——VM4Q0832X2GLG VM4Q0832X2R5G VM4Q0832X2ERN
165 3/4" 120 VM5 ——VM5Q161X2GLG VM5Q161X2R5G VM5Q161X2ERN
200-277 ——VM5Q1632X2GLG VM5Q1632X2R5G VM5Q1632X2ERN
VM 55-165W QL INDUCTION WALL2(INCLUDES LAMP)
DESCRIPTION
HUB
SIZE3
TANK
STYLEVOLTAGE
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
ENCLOSED
REFRACTOR
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
55 3/4" 120 VM1 VM1Q051B2GLG VM1Q051B2R5G ——
200-277 VM1Q0532B2GLG VM1Q0532B2R5G ——
85 3/4" 120 VM4 ——VM4Q081B2GLG VM4Q081B2R5G VM4Q081B2ERN
200-277 ——VM4Q0832B2GLG VM4Q0832B2R5G VM4Q0832B2ERN
165 3/4" 120 VM5 ——VM5Q161B2GLG VM5Q161B2R5G VM5Q161B2ERN
200-277 ——VM5Q1632B2GLG VM5Q1632B2R5G VM5Q1632B2ERN
VM 55-165W QL INDUCTION CONE2(INCLUDES LAMP)
DESCRIPTION
HUB
SIZE3
TANK
STYLEVOLTAGE
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
ENCLOSED
REFRACTOR
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
55 3/4" 120 VM1 VM1Q051C2GLG VM1Q051C2R5G ——
200-277 VM1Q0532C2GLG VM1Q0532C2R5G ——
85 3/4" 120 VM4 ——VM4Q081C2GLG VM4Q081C2R5G VM4Q081C2ERN
200-277 ——VM4Q0832C2GLG VM4Q0832C2R5G VM4Q0832C2ERN
165 3/4" 120 VM5 ——VM5Q161C2GLG VM5Q161C2R5G VM5Q161C2ERN
200-277 ——VM5Q1632C2GLG VM5Q1632C2R5G VM5Q1632C2ERN
CERTILITE®V SERIES LIGHTING
QL INDUCTION, 55/85/165W
L92
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Suitable for wet locations
NEMA 3, 4, 4x
Listed - File LR11713
1See hazardous application data on pages L108-L111 for limitations.
2Globe catalog number shown with guard. To omit guard, change G to N; e.g. VM4Q081D5GLN. Order spin top and enclosed
reflector guards separately.
3Stanchion catalog numbers shown are with 1-1/2" conduit openings, change “5” to “4” for 1-1/4"; e.g. VM4Q081D4GLG.
4VMEZA tank adapters are UL “classified” as an assembly for use between VM tanks and EZ mounts. Order EZ mounts separately.
See page L83.
Stanchion 25°
w/ Globe &
Guard
Stanchion 90°
w/ Spin-Top
Refractor
EZ Adapter
w/ Enclosed
Reflector
VM 55-165W QL INDUCTION 25° STANCHION2(INCLUDES LAMP)
DESCRIPTION
HUB
SIZE3
TANK
STYLEVOLTAGE
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
ENCLOSED
REFRACTOR
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
55 1-1/2" 120 VM1 VM1Q051D5GLG VM1Q051D5R5G ——
200-277 VM1Q0532D5GLG VM1Q0532D5R5G ——
85 1-1/2" 120 VM4 ——VM4Q081D5GLG VM4Q081D5R5G VM4Q081D5ERN
200-277 ——VM4Q0832D5GLG VM4Q0832D5R5G VM4Q0832D5ERN
165 1-1/2" 120 VM5 VM5Q161D5GLG VM5Q161D5R5G VM5Q161D5ERN
200-277 ——VM5Q1632D5GLG VM5Q1632D5R5G VM5Q1632D5ERN
VM 55-165W QL INDUCTION STRAIGHT STANCHION2(INCLUDES LAMP)
DESCRIPTION
HUB
SIZE3
TANK
STYLEVOLTAGE
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
ENCLOSED
REFRACTOR
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
55 1-1/2" 120 VM1 VM1Q051S5GLG VM1Q051S5R5G ——
200-277 VM1Q0532S5GLG VM1Q0532S5R5G ——
85 1-1/2" 120 VM4 ——VM4Q081S5GLG VM4Q081S5R5G VM4Q081S5ERN
200-277 ——VM4Q0832S5GLG VM4Q0832S5R5G VM4Q0832S5ERN
165 1-1/2" 120 VM5 ——VM5Q161S5GLG VM5Q161S5R5G VM5Q161S5ERN
200-277 ——VM5Q1632S5GLG VM5Q1632S5R5G VM5Q1632S5ERN
VM 55-165W QL INDUCTION EZ ADAPTER2(INCLUDES LAMP)
DESCRIPTION
HUB
SIZE3
TANK
STYLEVOLTAGE
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
ENCLOSED
REFRACTOR
TYPE V GLASS
REFRACTOR
& GUARD
WATTS
55 4120 VM1 VM1Q051EZGLG VM1Q051EZR5G ——
200-277 VM1Q0532EZGLG VM1Q0532EZR5G ——
85 4120 VM4 ——VM4Q081EZGLG VM4Q081EZR5G VM4Q081EZERN
200-277 ——VM4Q0832EZGLG VM4Q0832EZR5G VM4Q0832EZERN
165 4120 VM5 ——VM5Q161EZGLG VM5Q161EZR5G VM5Q161EZERN
200-277 ——VM5Q1632EZGLG VM5Q1632EZR5G VM5Q1632EZERN
CERTILITE®V SERIES LIGHTING
ACCESSORIES/OPTIONS L93
PHOTO CONTROL FOR STANDARD AND HAZARDOUS CLASS I DIVISION 2 AREAS2
HUB2PC120
HUB2PC2273
HUB2PC347
CATALOG NUMBER
120VAC
208-277VAC3
347VAC
VOLTS
50/60Hz
50/60Hz
50/60Hz
FREQUENCY
400
400
440
WATTS
Photo Control
(Field Installed
in Splice cap)
Photo Control1
(Factory Installed
in ballast tank)
Photo Control
Component
(Patented)
Photo Control
Component
UL/CSA
C1, DIV.2 & N4X
FACTORY SEALED
FACTORY SEALED
1Must be factory installed. Add P1 (for 120V), P2 (for 208-277V) or P3 (for 347V) suffixes are also for use
with KFxxx - 76 Floods and KWP Series Wallpack Luminaires.
2Photo control cells for Class 1 Division 2 only.
3Marked 220-277V, suitable for 208V.
140˚C ambient T3 Rated.
* Includes photo cell and factory drilled
cover and gasket.
1Order single gang FS box seperately.
240˚C ambient max. T3 to 400W max.
PHOTO CELL FIELD KITS*
HUB2PC120FK
HUB2PC277FK
HUB2PC347FK
CATALOG NUMBER1
120VAC
208-277VAC
347VAC
VOLTS
50/60Hz
50/60Hz
50/60Hz
FREQUENCY
HKB-GL PHOTO CELLS
VMHKPC1
VMHKPC2
VMHKPC3
CATALOG NUMBER1
120VAC
208-277VAC
347VAC
VOLTS
FS COVER MOUNTED PHOTO CELLS*
VMFSPC1
VMFSPC2
VMFSPC3
CATALOG NUMBER12
120VAC
208-277VAC
347VAC
VOLTS
Class I, DIV. 1 BCD
Class II, DIV. 1&2 EFG
CLASS III
NEMA 3, 4X IP66
CERTILITE®V PHOTO CELL ACCESSORY
Auxiliary Lighting
Momentary voltage outages or dips can tem-
porarily extinguish HID lamps which may
require up to ten (10) minutes to restrike. To
provide illumination during this period, about
10% of the fixtures should be specified with
auxiliary lighting.
Quartz Auxiliary
Quartz auxiliary is available for all Certilite®V
Series fixtures (except those with plastic
refractors) by adding the suffix QAto the
fixture catalog number. Example:
VM3S050A2GLG-QA.
Low wattage fixtures with this option use 100
or 150 watt quartz lamps. High wattage fix-
tures can use up to 250 watt quartz lamps.
Quartz lamps are not supplied with the fixture.
Use quartz lamp type Q100 CL/DC (100W) or
Q150 CL/DC (150W) DC Bayonet T-4 Base.
Due to the quartz envelope surface tempera-
ture (exceeding 60C), fixtures with this option
are not suitable for Class I, Division 2, Class l,
Zone 2, some Class l, Zone 2 Ex nR, Class II
and Class Ill hazardous locations. Contact the
factory for specific fixture suitabilities.
Instant Restrike
Available for low wattage High Pressure
Sodium Fixtures by adding Suffix IRto cata-
log number Example: VM3S050A2GLG-IR.
Additional instant restrike interior circuitry may
decrease High Pressure Sodium lamp life.
Feature will not affect fixture suitability in
hazardous location applications.
Ballast Protection Circuit
Optional factory installed special ballast pro-
tector replaces the standard HPS ignitor and
applies starting pulse to the lamp for 10 to 15
seconds each time voltage is supplied to the
ballast. If the lamp has not ignited by the end
of the time period, the starter will cease puls-
ing. Used to eliminate the continuous high
voltage pulsing of the ignitor when end of life,
lamp cycling, or missing lamp conditions
exist. Available for HPS fixtures. Add suffix
“BPto fixture catalog number.
Notes: BP and IR cannot be used together.
QTZ and IR cannot beused together.
L
* Includes instructions for KF/KWP Series.
140˚C ambient max. C1 D2 (T3) to 400W max.
CERTILITE®V SERIES LIGHTING
COMPONENTS
L94
CERTILITE®VVM MOUNTING SPLICE BOXES
3/4"
1"
1-1/4"
1-1/2"
M-20
HUB SIZE
VMA2B
VMA3B
PENDANT
VMF2B
VMF3B
FLEXIBLE PENDANT
VMX2B
VMX3B
VMX8B**
CEILING 4 HUB
VMX6B
VMX7B
VMX9B
CEILING 5 HUB
VMB2B
VMB3B
WALL
VMC2B
VMC3B
CONE TOP
VMD4B
VMD5B
25 DEGREE STANCHION
VMS4B
VMS5B
90 DEGREE STANCHION
CATALOG NUMBER
Pendant Ceiling Wall
Flexible Pendant
25° StanchionCone Top Straight Stanchion EZ Adapter*
VMEZA
VM3 Low Wattage
5-1/2" Optic Thread Size
VM2 Low Wattage
7-3/4" Optic Thread Size
VM1 Low Wattage
5-1/2" Optic Thread Size
VM4 Low Wattage
7-3/4" Optic Thread Size
VM5 High Wattage
7-3/4" Optic Thread Size
*VMEZA is used between a ballast tank and an EZ mount-ordered separately. See L83 for more information.
**VMX8B furnished with 3 non-metallic plugs.
CERTILITE®VVM 35-600W BALLAST TANK ASSEMBLIES CATALOG NUMBERS
WATTS
VOLTAGE
@ 60 Hz
MEDIUM BASE E26 MOGUL BASE E39 SOCKET
HPS MH-MHP HPS
5-1/2" 7-3/4"
MH -MHP
7-3/4"
MH PULSE
HIGH WATTAGE
LOW WATTAGE
5-1/2" 7-3/4" 7-3/4"
HIGH WATTAGE
LOW WATTAGE
5-1/2" 7-3/4" 7-3/4"
HIGH WATTAGE
LOW WATTAGE
5-1/2" 7-3/4"5-1/2" 7-3/4"
LOW WATTAGELOW WATTAGE
35 120 VM1S031 VM2S031 —— —— ——
Quad VM1S050 VM2S050 VM1H050 VM2H050 VM3S050 VM4S050 ———————
50 Tri ——VM1H056 VM2H056 VM3S056 VM4S056 ——————
480 ———VM3S055 VM4S055 ———————
Quad VM1S070 VM2S070 VM1H070 VM2H070 VM3S070 VM4S070 VM3H070 VM4H070 ————
70 Tri VM1S076 VM2S076 VM1H076 VM2H076 VM3S076 VM4S076 VM3H076 VM4H076 ————
480 VM1S075 VM2S075 VM1H075 VM2H075 VM3S075 VM4S075 VM3H075 VM4H075 ————
Quad VM1S100 VM2S100 VM1H100 VM2H100 VM3S100 VM4S100 VM3H100 VM4H100 ————
100 Tri VM1S106 VM2S106 VM1H106 VM2H106 VM3S106 VM4S106 VM3H106 VM4H106 ————
480 VM1S105 VM2S105 VM1H105 VM2H105 VM3S105 VM4S105 VM3H105 VM4H105 ————
Quad VM1S150 VM2S150 VM1P150 VM2P150 VM3S150 VM4S150 ————VM3P150 VM4P150
150 Tri VM1S156 VM2S156 VM1P156 VM2P156 VM3S156 VM4S156 ————VM3P156 VM4P156
480 VM1S155 VM2S155 VM1P155 VM2P155 VM3S155 VM4S155 ————VM3P155 VM4P155
Quad ——VM1P170 VM2P170 —— —VM3H170 VM4H170 VM3P150 VM4P150
175 Tri ——VM1P176 VM2P176 —— —VM3H176 VM4H176 VM3P156 VM4P156
480 ——VM1P175 VM2P175 —— —VM3H175 VM4H175 — VM3P155 VM4P155 —
Quad ——— VM5S200 —— —VM3P200 VM4P200
200 Tri ———VM5S206 —— —VM3P206 VM4P206
480 ——— VM5S205 —— —VM3P205 VM4P205
Quad ——— VM5S250 VM3H250 VM4H250 ——VM5P250
250 Tri ———VM5S256 VM3H256 VM4H256 ——VM5P256
480 ——— VM5S255 VM3H255 VM4H255 ——VM5P255
Quad —— —— ——VM5P320
320 Tri —— —— ——VM5P326
480 —— —— ——VM5P325
Quad —— —— ——VM5P350
350 Tri —— —— ——VM5P356
480 —— —— ——VM5P355
Quad ——— VM5S400 ——VM5H400 ——VM5P400
400 Tri ———VM5S406 ——VM5H406 ——VM5P406
480 ——— VM5S405 ——VM5H405 ——VM5P405
Quad ——— VM5S600 —— — —— —
600 Tri ———VM5S606 —— — —— —
480 ——— VM5S605 —— — —— —
CERTILITE®V SERIES LIGHTING
COMPONENTS L95
L
CERTILITE®VREFLECTORS
VMAG172VMRWG84
VMER40
VMG40
VMG25
VMAG25S3VMAG40S3
VMR255
VMR253
VMR251
VZRG1550 VZRG2550
VZRG2520
VZRP1756
VMEP408
CERTILITE®VOPTICS & GUARDS
DESCRIPTION
Globe (glass)
Refractor (all glass) Type V
Refractor (all glass) Type I
Refractor (all glass) Type III
Refractor (spin top glass) 8" Type V
Refractor (spin top glass) 12" Type V
Refractor (spin top glass) 12" Type II
Refractor (spin top plastic) 12" Type V
Enclosed Reflector (glass lens)
Enclosed Reflector (plastic lens)
Globe (Tuffskin®coated)5
Globe (Teflon®coated)5
Refractor (Teflon coated) Type V
Refractor (Teflon coated) Type I
Refractor (Teflon coated) Type III
Refractor (Spin Top Teflon coated) 8" Type V
Refractor (Spin Top Teflon coated) 12" Type V
Refractor (Spin Top Teflon coated) 12" Type II
OPTICS
VMG17
VMR175
VMR1717
VZRG1550
VZRG2550
VZRG2520
VZRP175
VMG17F
VMG17T
VMR175T
VMR171T
VZRG2550T
VZRG2520T
GUARD
VMAG17
VMAG17
VMAG17
VMRWG8
VMRWG
VMRWG
VMRWG
VMAG17
VMAG17
VMAG17
VMAG17
VMRWG8
VMRWG
VMRWG
OPTICS
VMG25
VMR255
VMR2517
VMR2537
VZRG40501
VZRG40201
VMER40
VMEP40
VMG25F
VMG25T
VMR255T
VMR251T
VMR253T
VZRG4050T1
VZRG4020T1
GUARD
VMAG25S
VMAG25S
VMAG25S
VMAG25S
VMRWG
VMRWG
VMERG
VMAG25S
VMAG25S
VMAG25S
VMAG25S
VMAG25S
VMRWG
VMRWG
OPTICS
VMG40
VZRG4050
VZRG4020
VMER40
VMEP40
VMG40F
VMG40T
VZRG4050T
VZRG4020T
GUARD
VMAG40S
VMRWG
VMRWG
VMERG
VMAG40S
VMAG40S
VMRWG
VMRWG
1For reference VM5 Spin Top optics fit VM4 tanks, but VM3 tanks and optics
are recommended for low wattage Spin Top applications. VM3 12" Spin Tops
ship with a mogul-to-mogul extender for improved photometrics.
2Standard material, copper-free aluminum painted.
3Standard material, 316 stainless steel.
4Standard material, plated steel.
5Tuffskin®is a registered trademark of Thomas Manufacturing, Co. Teflon®is a
registered trademark of DuPont, Inc. Alzak is a registered trademark of Alcoa.
6175W max; not hazloc listed
7Type I (III) all-glass refractors align with fixture hinge. Ceiling mount unit utiliz-
ing these optics must have offset conduit feed.
8For wall applications, mount must be spaced out.
HRD400
VMPSD40 VMPA40 HRD400ALZ
Standard Dome
Fiberglass White Reflector
Dia: 16"
30OAngle
Fiberglass White
Reflector Dia: 16"
Deep Aluminum
White Reflector
Dia: 21"
Deep Aluminum
Anodized Reflector
Dia: 21"
VMAG172
VMR175
VMR171
VMG17
VMRWGS3VMAG25S3VMERG3
VZRG4050
VZRG4020
VMRWG83
O
P
T
I
C
S
G
U
A
R
D
S
VM5 High Wattage
7-3/4" Optic Thread Size
VM2/VM4/VM5QL Low Wattage
7-3/4" Optic Thread Size
VM1/VM3 Low Wattage
5-1/2" Optic Thread Size
VMAGBC
Bottom Closure for
VMAG25S/VMAG40S
Attach to
Building
Structure.
Need a Hand?
CERTILITE®V SERIES LIGHTING
ACCESSORIES/REPLACEMENT PARTS
L96
VMCHVM adapter for
upgrading existing
Crouse-Hinds®to Killark,
see page L223 for more
information.
See page
L56 for more
information.
SOCKET REPLACEMENTS
0735015B
VMBNKIT
Mogul Socket VM3, VM4, VM5
Barrel nut and long bolt adapts older CertiLite
tanks to newer CertiLiteV®mo unts.
Crouse-Hinds is a registered trademark of Cooper Crouse-Hinds, LLC,
SUSPENSION DEVICES4
DESCRIPTION
“3rd hand” safety kits. 24" stainless cable holds globe using guard for lamp
change out. Attaches to tank’s built-in “Earthquake Tab”.
10' Stainless Steel Safety Cable with loop grip. Drop limit 1'. Attaches to
“Earthquake Tab” (L41) and to building structure (e.g. I-beam).
CATALOG NUMBER
See catalog logic for factory installed fuses, or page L98-99 for field installation kits.
TA NK
VM GLOBE &
GUARD UNITS
VM
(ALL TANKS)
DARK SKY KITS
VMDARK1 Gasket Kit
VMER40 Enclosed Reflector
On VM2/VM4 “Full Cutoff” when used with HRD400 or HRD400ALZ
On VM5 “Cutoff” when used with HRD400 or HRD400ALZ
Enclosed Reflector “Full Cutoff” on VM2/VM4/VM5 as standard
4VM2,VM4 and VM5 units require VMAGBC bottom closure, sold separately, in addition to guard.
FUSE KITS
VMAGSC4
VMSC10
Note: CertiLite®Vluminaires may be configured for “Full Cutoff”, or Semi-Cutoff photometric distribution.
See page L56 for more information.
POWERFUL
Luminaire Layout
and Calculation
Software
Software is used to determine
number of fixtures required and
their proper layout for various
tasks and applications.
Contact you local Killark sales
representative for availability.
DESIGNDESIGN
LIGHTING DESIGN SOFTWARE
Existing box
VMCHVM adapter
shown in red
for illustration
New Killark VM
series fixture
VM SERIES LIGHTING
CERTILITE®TO CERTILITE®VL97
L
GENERAL CROSS-REFERENCE FOR CERTILITE®TO CERTILITE®V***
WATTS
50
70
100
150
250
400
70
100
175
250
400
175
250
320
350
400
100
175
250
400
ANSI
LAMP TYPE
S68
S62
S54
S55
S50
S51
M98
M90
M57
M58
M59
M137
M138
M132
M131
M135
H38
H39
H37
H33
GLOBE
& GUARD
VML1-1-13GG
VM3S05211GLG
VML1-1-42GG
VM3S07211GLG
VML1-1-52GG
VM3S10211GLG
VML1-1-92GG
VM3S15211GLG
VMV1-1-72GG
VM5S25211GLG
VMV1-1-82GG
VM5S40211GLG
VMM1-1-42GG
VM3H07211GLG
VMM1-1-52GG
VM3H10211GLG
VMM1-1-62GG
VM3H17211GLG
VMM1-1-72GG
VM3H25211GLG
VMF1-1-82GG
VM5H40211GLG
VMU1-1-62GG
VM3P17211GLG
VMP1-1-72GG
VM5P25211GLG
VMP1-1-322GG
VM5P32211GLG
VMP1-1-352GG
VM5P35211GLG
VMP1-1-82GG
VM5P40211GLG
VMK1-1-52GG
VM3M10211GLG
VMK1-1-62GG
VM3M17211GLG
VMK1-1-72GG
VM3M25211GLG
VME1-1-82GG
VM5M40211GLG
HPS
MH
MHP
MV
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
Certilite®
Certilite®V
SPIN-TOP
REFRACTOR
VML1-1-12G58
VM3S05211S8N
VML1-1-42G58
VM3S07211S8N
VML1-1-52G58
VM3S10211S8N
VML1-1-92G58
VM3S15211S8N
VMV1-1-72G5
VM5S25211S5N
VMV1-1-82G5
VM5S40211S5N
VMM1-1-42G58
VM3H07211S8N
VMM1-1-52G58
VM3H10211S8N
VMM1-1-62G58
VM3H17211S5N
VMM1-1-72G58
VM3H25211S5N
VMF1-1-82G5
VM5H40211S5N
VMU1-1-62G58
VM3P17211S8N
VMP1-1-72G5
VM5P25211S5N
VMP1-1-322G5
VM5P32211S5N
VMP1-1-352G5
VM5P35211S5N
VMP1-1-82G5
VM5P40211S5N
VMK1-1-52G58
VM3M10211S8N
VMK1-1-62G58
VM3M17211S8N
VMK1-1-72G58
VM3M25211S8N
VME1-1-82G5
VM5M40211S5N
ENCLOSED
REFLECTOR
VMV1-1-72ER
VM5S25211ERN
VMV1-1-82ER
VM5S40211ERN
VMF1-1-82ER
VM5H40211ERN
VMP1-1-72ER
VM5P25211ERN
VMP1-1-322ER
VM5P32211ERN
VMP1-1-352ER
VM5P35211ERN
VMP1-1-82ER
VM5P40211ERN
VME1-1-82ER
VM5M40211ERN
TANK ONLY
VMLO-0-120
VM3S052
VMLO-0-420
VM3S072
VMLO-0-520
VM3S102
VMLO-0-920
VM3S152
VMVO-0-720
VM5S252
VMVO-0-820
VM5S402
VMMO-0-420
VM3H072
VMMO-0-520
VM3H102
VMMO-0-620
VM3H172
VMMO-0-720
VM3H252
VMFO-0-820
VM5H402
VMUO-0-620
VM3P172
VMPO-0-720
VM5P252
VMPO-0-3220
VM5P322
VMPO-0-3520
VM5P352
VMPO-0-820
VM5P402
VMKO-0-520
VM3M102
VMKO-0-620
VM3M172
VMKO-0-720
VM3M252
VMEO-0-820
VM5M402
*** See catalog logic for more information regarding additional conduit sizing and fixture options and accessories.
4175-400W MH Fixtures are EXPORT ONLY (EISA LAW).
MOUNT CODES 1 1
Certilite®
1-1
A-2
A-3
B-2
B-3
C-2
D-4
D-5
S-5
X-2
X-3
Certilite®V
11
A2
A3
B2
B3
C2
D4
D5
S5
X2
X3
DESCRIPTION
3/4" Pendant
1" Pendant
3/4" Wall Bracket
1" Wall Bracket
3/4" Cone Top
1-1/4" 25° Stanchion
1-1/2" 25° Stanchion
1-1/2" 90° Stanchion
3/4" Ceiling
1" Ceiling
VOLTAGE CODES 2
Certilite®
0
6
5
7
8
Certilite®V
0
6
5
7
8
DESCRIPTION
Quad-Tap 120, 208, 240, 277V 60Hz
Tri-Tap 120, 277, 347V 60Hz
480V 60Hz
220V 60Hz
240V 50Hz
OPTIONS
Certilite®
QTZ
IR
BP
NR
SU103
Certilite®V
QA
IR
BP
NR
AS
DESCRIPTION
Quartz Auxiliary
Instant Restart
Ballast Protector
Restricted Breathing
Assembled w/Standard Lamp
COMPONENTS
CertiLite®
VMA-2
VMA-3
VMB-2
VMB-3
VMC-2
VMD-4
VMD-5
VMDS-5
VMX-2
VMX-3
VMG-17
VMGT-17
VMGTC-17
VMG-40
VZRG-1550
VZRG-2550
VZRG-2510
VZRP-175
VZRG-4050
VZRG-4020
VMER40
VMAG-17
VMAG-40
VMRWG-8
VMRWG
VMPSD-17
VMPA-17
VMPSD-40
VMPA-40
HRD-400
HRD-400ALZ
CertiLite®V
VMA2B
VMA3B
VMB2B
VMB3B
VMC2B
VMD4B
VMD5B
VMS5B
VMX2B
VMX3B
VMG17
VMG17F
VMG17T
VMG40
VZRG1550
VZRG2550
VZRG2520
VZRP175
VZRG4050
VZRG4020
VMER40
VMAG17
VMAG40S
VMRWG8
VMRWG
VMPSD40
VMPA40
VMPSD40
VMPA40
HRD400
HRD400ALZ
DESCRIPTION
3/4" Pendant
1" Pendant
3/4" Wall Bracket
1" Wall Bracket
3/4" Cone Top
1-1/4" 25° Stanchion
1-1/2" 25° Stanchion
1-1/2" 90° Stanchion
3/4" Ceiling
1" Ceiling
5-1/2" GLOBE
TUFFSKIN GLOBE
TELFON GLOBE
7-3/4" HIGH WATT GLOBE
8" SPIN-TOP V REFRACTOR
12" SPIN-TOP V REFRACTOR
12" SPIN-TOP II REFRACTOR
12" POLY REFRACTOR
12" SPIN-TOP V REFRACTOR
12" SPIN-TOP II REFRACTOR
ENCLOSED REFLECTOR
5-1/2" GLOBE GUARD
HIGH WATT GLOBE GUARD
8" SPIN-TOP GUARD
12" SPIN-TOP GUARD
WHITE REFLECTOR3
WHITE ANGLE REFLECTOR3
WHITE REFLECTOR
WHITE ANGLE REFLECTOR
DEEP WHITE REFLECTOR
DEEP ALZAK REFLECTOR
M
O
U
N
T
S
O
P
T
I
C
S
G
U
A
R
D
S
R
E
F
L
E
C
T
O
R
S
3All Certilite®V tanks use “40” reflectors.
CertiLite®
VM Fixture
CertiLite®V
Fixture
4
VM & EZ SERIES • LIGHTING
HID FIXTURES • BALLAST/FUSE KIT DATA
L98
LAMP LAMP CURRENT (AMPS) INPUT BALLAST MIN.
SOURCE WATTS/TYPE VOLTAGE START OPERATING OPEN WATTS CIRCUIT2REGULATION START
HID BALLAST DATA & FUSE KITS1
1Fuse kits, for field installation, must be used within guidelines of governing Electric Codes. Fuses not permitted by
CSA C22.2 no. 137 for Canada.
2All ballasts circuits are High Power Factor 90%+.
* Lamp watts: within ANSI trapezoid limitations.
Consult major lamp & ballast manufacturer catalogs if more detailed data is needed.
EZ FUSE KIT
HPS 35 120 .78 .38 .65 46 R/HPF ±5% VOLTAGE* -40C
S-76 ±5% WATTAGE -40F
120 .58 .58 1.24
HPS 50 208 .35 .33 .59 66 HX/HPF ±5% VOLTAGE* -40C
S-68 240 .30 .29 .50 ±12% WATTAGE -40F
277 .24 .25 .44
220-240/50 .32 .32 .55 66 HX/HPF ±10% VOLTAGE* -40C
±10% WATTAGE -40F
120 .75 .81 1.45
208 .45 .47 .85
240 .35 .40 .75 93 HX/HPF ±5% VOLTAGE* -40C
HPS 70 277 .37 .35 .65 ±12% WATTAGE -40F
S-62 480 .21 .21 .36
347 .28 .30 0.52
220-240/50 .45 .46 .75 94 HX/HPF ±5% VOLTAGE* -40C
±5% WATTAGE -40F
120 1.30 1.15 2.20
208 .76 .67 1.27
240 .66 .58 1.10
HPS 100 277 .60 .50 .85 130 HX/HPF ±5% VOLTAGE* -40C
S-54 480 0.35 0.29 .55 ±12% WATTAGE -40F
347 .44 .39 .70
220-240/50 .56/.51 .67/.62 1.28/1.17
120 2.00 1.65 2.80
208 1.15 .95 1.60
150 240 1.00 .83 1.40
HPS (55 VOLT LAMP) 277 .85 .72 1.25 188 HX/HPF ±5% VOLTAGE* -40C
S-55 480 .50 .42 .70 ±12% WATTAGE -40F
347 .52 .59 .92
220-240/50 1.27/1.16 .91/.83 1.52/1.40
120 1.50 2.2 1.3
208 .90 1.28 .75
HPS 200 240 .75 1.11 .65
S-66 277 .65 .96 .60 240 CWA ±10% VOLTAGE* -40C
480 .35 .58 .58 ±8% WATTAGE -40F
120 1.80 2.75 1.50
208 1.00 1.60 .87
240 .90 1.38 .75
HPS 250 277 .78 1.20 .65 295 CWA ±10% VOLTAGE* -40C
S-50 480 .38 .69 .37 ±5% WATTAGE -40F
347 .56 .93 .75
220-240/50 1.00/.90 .91/.83 .90/.80
120 2.82 4.30 1.83
208 1.56 2.48 1.15
240 1.36 2.15 .84 ±10% VOLTAGE* -40C
HPS 400 277 1.18 1.86 .71 464 CWA ±5% WATTAGE -40F
S-51 480 .60 1.00 .75
347 1.05 1.40 .75
220-240/50 1.65/1.50 2.30/2.10 1.20/1.10
120 5.25 5.50 3.0
208 3.00 3.25 1.75
600 240 2.60 2.85 1.80 ±10% VOLTAGE* -40C
HPS S-106 277 2.15 2.50 1.40 685 CWA ±10% WATTAGE -40F
480 1.2 1.43 .75
347 1.7 2.00 1.10
120 .46 .58 1.2
208 .27 .33 .68
MH 50 240 .17 .21 .59 67 HX-HPF ±5% VOLTAGE -30C
M-110 277 .20 .25 .51 ±10% WATTAGE -20F
347 .21 .24 .48
120 .80 .85 1.70
208 .50 .50 1.04
MH 70 240 .43 .43 .87 90 HX-HPF ±5% VOLTAGE -30C
M-98 277 .39 .39 .78 ±12% WATTAGE -20F
480 0.19 0.23 .50
347 .30 .30 .60
120 1.20 1.15 2.3
208 .70 1.50 .60
100 240 .61 1.30 .55 ±5% VOLTAGE -30C
MH M-90 277 .55 1.15 .45 129 HX-HPF ±12% WATTAGE -20F
480 0.30 0.30 0.55
347 .40 .90 .40
220-240/50 .45/.41 52/.51 .60/.85
120 .80 1.80 1.80
208 .42 1.04 1.04
240 .42 .90 .90
MH 175 277 .35 .78 .78 210 CWA ±10% VOLTAGE -30C
M-57 480 .22 .45 .45 ±5% WATTAGE -20F
347 .42 .62 .62
220-240/50 .60/.55 .98/.90 97/.89
120 1.25 2.60 2.50
208 .65 1.50 1.58
250 240 .60 1.30 1.25 ±10% VOLTAGE -30C
MH M-58 277 .50 1.12 1.10 295 CWA
480 .25 .65 .65 ±5% WATTAGE -20F
347 .90 .95 .65
220-240/50 .94/.86 1.35/1.24 1.20/1.10
120 1.10 4.00 3.80
208 .70 2.30 2.20
400 240 .52 2.00 1.90 ±10% VOLTAGE -30C
MH M-59 277 .45 1.75 1.65 458 CWA
480 .38 1.00 1.00 ±5% WATTAGE -20F
347 1.20 1.40 1.35
220-240/50 1.30/1.19 2.20/2.00 2.10/1.93
1VM-2
1VM-5
2VM-3
2VM-3
1VM-2
1VM-2
1VM-5
2VM-3
2VM-2
1VM-2
2VM-2
1VM-2
1VM-2
1VM-7
2VM-5
2VM-3
1VM-3
2VM-3
1VM-3
1VM-4
1VM-10
2VM-5
2VM-5
1VM-4
2VM-2
1VM-3
1VM-5
1VM-6
2VM-4
2VM-3
1VM-3
2VM-2
1VM-7
2VM-4
2VM-4
1VM-3
2VM-2
1VM-2
1VM-4
1VM-10
2VM-8
2VM-5
1VM-5
2VM-3
1VM-5
1VM-6
1VM-20
2VM-15
2VM-10
1VM-10
2VM-4
1VM-5
1VM-3
2VM-2
2VM-2
1VM-2
1VM-2
1VM-4
2VM-3
2VM-2
1VM-2
2VM-1
1VM-2
1VM-6
2VM-4
2VM-3
1VM-3
2VM-2
1VM-2
1VM-4
1VM-5
2VM-3
2VM-3
1VM-2
2VM-2
1VM-2
1VM-3
1VM-8
2VM-5
2VM-5
1VM-3
2VM-2
1VM-3
1VM-4
1VM-10
2VM-7
2VM-5
1VM-5
2VM-4
1VM-4
1VM-6
1FK-5
2FK-3
2FK-3
1FK-2
1FK-2
1FK-5
2FK-3
2FK-2
1FK-2
2FK-2
1FK-2
1FK-2
1FK-7
2FK-5
2FK-3
1FK-3
2FK-3
1FK-3
1FK-4
1FK-10
2FK-5
2FK-5
1FK-4
2FK-2
1FK-3
1FK-5
1FK-7
2FK-4
2FK-4
1FK-3
2FK-2
1FK-2
1FK-4
1FK-10
2FK-8
2FK-5
1FK-5
2FK-3
1FK-5
1FK-6
1FK-3
2FK-2
2FK-2
1FK-2
1FK-2
1FK-4
2FK-3
2FK-2
1FK-2
2FK-1
1FK-2
1FK-6
2FK-4
2FK-3
1FK-3
2FK-2
1FK-2
1FK-4
1FK-5
2FK-3
2FK-3
1FK-2
2FK-2
1FK-2
1FK-3
1FK-8
2FK-5
2FK-5
1FK-3
2FK-2
1FK-3
1FK-4
1FK-10
2FK-7
2FK-5
1FK-5
2FK-4
2FK-4
2FK-6
VM FUSE KIT
VM & EZ SERIES LIGHTING
HID AND INDUCTION FIXTURES BALLAST/FUSE KIT DATA L99
L
LAMP LAMP CURRENT (AMPS) INPUT BALLAST MIN.
SOURCE WATTS/TYPE VOLTAGE START OPERATING OPEN WATTS CIRCUIT2REGULATION START
120 0.85 1.40 0.90
208 0.50 0.80 0.55
125 240 0.40 0.70 0.45
MHP M-150 277 0.35 0.60 0.40 155 C WA
480 0.20 0.35 0.25
347 0.30 0.45 0.25
120 1.75 1.60 3.65
208 1.30 1.00 2.10
150 240 0.85 0.80 1.80
MHP M-102 277 0.77 0.70 1.58 185 HX-HPF
480 0.45 0.42 0.81
347 0.30 0.62 0.98
120 0.95 1.80 1.80
208 0.55 1.05 1.05
MHP 175 240 0.45 0.90 0.90 208 CWA ±10% VOLTAGE
M-137 277 0.40 0.80 0.80 ±10% WATTAGE
480 0.25 0.50 0.45
347 0.40 0.70 0.60
120 2.30 2.50 1.40
208 1.30 1.45 0.80
250 240 1.15 1.25 0.70 2 91 CWA ±10% VOLTAGE
MHP M-138 277 1.00 1.10 0.60 ±10% WATTAGE
480 0.21 0.57 0.48
347 0.45 0.95 0.75
120 1.80 3.25 2.30
208 1.05 1.90 1.35
320 240 0.30 1.65 1.15
MHP M-132 277 0.80 1.40 1.00 3 68 CWA
480 0.45 0.80 0.60
347 0.70 1.10 0.80
120 2.20 3.40 2.20
208 1.30 2.00 1.30
350 240 1.10 1.70 1.10
MHP M-131 277 1.00 1.50 1.00 4 00 CWA
480 0.60 0.85 0.60
347 0.85 1.20 0.80
120 2.85 3.80 2.20
208 1.65 2.20 1.50
400 240 1.45 1.90 1.10
MHP M-135 277 1.25 1.65 0.95 4 52 CWA
480 0.75 1.00 0.60
347 1.10 1.35 0.75
HID BALLAST DATA & FUSE KIT1
VM FUSE KIT
1VM-4
2VM-3
2VM-2
1VM-2
2VM-1
1VM-1
1VM-10
2VM-5
2VM-5
1VM-4
2VM-3
1VM-3
1VM-5
2VM-3
2VM-3
1VM-2
2VM-2
1VM-2
1VM-8
2VM-5
2VM-5
1VM-3
2VM-2
1VM-3
1VM-8
2VM-6
2VM-5
1VM-3
2VM-5
1VM-3
1VM-10
2VM-7
2VM-5
1VM-5
2VM-3
1VM-3
1VM-10
2VM-7
2VM-5
1VM-5
2VM-3
1VM-4
EZ FUSE KIT
1FK-4
2FK-3
2FK-2
1FK-2
2FK-1
2FK-2
1FK-10
2FK-5
2FK-5
1FK-4
2FK-3
1FK-3
1FK-5
2FK-3
2FK-3
1FK-2
2FK-2
1FK-2
1FK-8
2FK-5
2FK-5
1FK-3
2FK-2
1FK-3
1FK-8
2FK-6
2FK-5
1FK-3
2FK-5
1FK-3
1FK-10
2FK-7
2FK-5
1FK-5
2FK-3
1FK-3
1FK-10
2FK-7
2FK-5
1FK-5
2FK-3
1FK-4
-30C
-20F
-30C
-20F
-30C
-20F
-30C
-20F
±10% VOLTAGE
±10% WATTAGE
±5% VOLTAGE
±12% WATTAGE
±10% VOLTAGE
±10% WATTAGE
±10% VOLTAGE
±10% WATTAGE
-30C
-20F
-30C
-20F
±10% VOLTAGE
±10% WATTAGE
1Fuse kits, for field installation, must be used within guidelines of governing Electric Codes. Fuses not permitted by CSA C22.2 no.137 for Canada.
2All ballasts circuits are High Power Factor 90%+.
3Nominal voltages measured at 115V or 230V.
* Lamp watts: within ANSI trapezoid limitations .
Consult major lamp & ballast manufacturer catalogs if more detailed data is needed.
-30C
-20F
LAMP LAMP VOLTAGE INRUSH CURRENT NOMINAL
SOURCE WATTS/TYPE .005 SEC OPERATING CURRENT THD REGULATION MIN. START
120
120 16A
16A .46A
.46A
< 1 0 %
<10% ± 2 0 V, ± 2 % W
±20V, ± 2 % W
Induction
Induct i o n 5 5
5 5
200-277
200-277 12A
12A .26A
.26A
1 2 0
120 16A
16A .73A
.73A
<10%
<10% ± 2 0 V, ± 2 % W
±20V, ± 2 % W
Induction
Induct i o n 8 5
8 5
200-277
200-277 12A
12A .40A
.40A
1 2 0
120 28A
28A 1.42A
1.42A
< 1 0 %
<10% ± 2 0 V, ± 2 % W
±20V, ± 2 % W
Induction
Induct i o n 165
165
200-277
200-277 24A
24A .74A
.74A
QL INDUCTION BALLAST DATA
-40C
-40F
-40C
-40F
-40C
-40F
CERTILITE®V SERIES MOUNTING BOX AND FIXTURE
DIMENSIONS
L100
hole dia.
.30"
(7.62)
hole dia.
.34"
(8.63)
For VM1 & VM2 height,
deduct 1.56" (40mm) from
the VM3 or VM4 tank
respectively, or overall
dimensions with same
mount and optic. All other
dimensions are the same.
CERTILITE®V SERIES FIXTURE
DIMENSIONS L101
L
For VM1 & VM2 height,
deduct 1.56" (40mm) from
the VM3 or VM4 tank
respectively, or overall
dimensions with same
mount and optic. All other
dimensions are the same.
CERTILITE®V SERIES FIXTURE
DIMENSIONS
L102
For VM1 & VM2 height,
deduct 1.56" (40mm) from
the VM3 or VM4 tank
respectively, or overall
dimensions with same
mount and optic. All other
dimensions are the same.
CERTILITE®V SERIES FIXTURE
DIMENSIONS L103
L
A
B
A
B
QL 165W uses VM5 tank
and VMG25 series optics,
VMAG25S guard
16.59 (421)
16.11 (409)
CERTILITE®V SERIES LIGHTING
APPLICATION DATA FOR HAZARDOUS LOCATIONS
L104
VM1/VM2 SERIES THERMAL PERFORMANCE DATA1
CLASS I DIVISION 2 GROUPS A,B,C,D / ZONE 2 GROUPS IIC, IIB, IIA
LAMP
TYPE
HPS
HPS
HPS
HPS
HPS
MH
MH
MH
MHP
MHP
QL
DESCRIPTION
LAMP
WATTAGE
35
50
70
100
150
50
70
100
150/125
175
55
AMBIENT
°C
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
VM1 SERIES**
GLOBE
ONLY
T3C
T3B
T3A
T3
T3
T3
T2C
T2C
T2B
T2B
T2C
325°C
325°C
T3
T3
T2D
T2C
T2C
T2B
T2B
T2A
T2A
350°C
350°C
450°C
T3C
GLOBE
W/ REFLECTOR
T3C
T3B
T3A
T3
T3
T3
T2C
T2C
T2B
T2B
T2B
325°C
325°C
T3
T3
T2D
T2C
T2B
T2B
T2B
T2A
T2A
350°C
350°C
450°C
T3C
VM2 SERIES**
VMR
T3C
T3B
T3A
T3
T3
T3
T2C
T2C
T2B
T2B
T2B
325°C
325°C
T3
T3
T2D
T2C
T2C
T2B
T2B
T2A
T2A
350°C
350°C
450°C
T3C
REFRACTORS
VZRG 8"
T3C
T3B
T3A
T3
T3
T3
T2C
T2C
T2B
T2B
T2B
325°C
325°C
T3
T3
T2D
T2C
T2C
T2B
T2B
T2A
T2A
350°C
350°C
450°C
T3C
VZRG 12"
T3C
T3B
T3A
T3
T3
T3
T2C
T2C
T2B
T2B
T2B
325°C
325°C
T3
T3
T2D
T2C
T2C
T2B
T2B
T2A
T2A
350°C
350°C
450°C
T3C
GLOBE
ONLY
T3C
T3B
T3A
T3
T3
T3
T2C
T2C
T2B
T2B
T2B
325°C
325°C
T3
T2D
T2D
T2C
T2C
T2B
T2A
T2A
T2A
325°C
325°C
450°C
450°C
GLOBE
W/ REFLECTOR
T3C
T3B
T3A
T3
T3
T3
T2C
T2B
T2B
T2B
T2B
325°C
325°C
T3
T2D
T2D
T2C
T2C
T2B
T2A
T2A
T2A
325°C
325°C
450°C
450°C
SUPPLY
WIRE °C
60
75
75
60
75
90
75
90
90
75
90
90
90
60
75
90
750
75
90
75
90
105
90
90
90
105
-75
ENCLOSED REFLECTORS
VMER40
T3C
T3B
T3A
T3
T3
T3
T2C
T2C
T2B
T2B
T2B
325°C
325°C
T3
T2D
T2D
T2C
T2C
T2B
T2B
T2A
T2A
325°C
325°C
450°C
450°C
VMEP40
T3C
T3B
T3A
T3
T3
T3
T2C
T2C
T2B
T2B
T2B
325°C
325°C
T3
T2D
T2D
T2C
T2C
T2B
T2B
T2A
T2A
325°C
325°C
450°C
450°C
REFRACTOR
VMR
T3C
T3B
T3A
T3
T3
T3
T2C
T2C
T2B
T2B
T2B
325°C
325°C
T3
T2D
T2D
T2C
T2C
T2B
T2B
T2A
T2A
325°C
325°C
450°C
450°C
T-CODE & TEMPERATURE RANGE CONVERSION TABLE °C
T1
351-450
350
326-350
325
301-325
T2
281-300
T2A
261-280
T2B
231-260
T2C
216-230
T2D
201-215
T3
181-200
T3A
166-180
T3B
161-165
T3C
136-160
T4
121-135
T4A
101-120
T5
86-100
T6
<=85
1Data does not apply to luminaries with auxiliary quartz lighting; consult factory with requirements.
The suitability of these fixtures for Class I Division 2 / Zone 2 locations must be determined for each
application based on NEC® Articles 501.125(B) or 505.
** VM1 Series accepts 5-1/2" threaded optics; VM2 accepts 7-3/4" optics.
— Not available.
CERTILITE®V SERIES LIGHTING
APPLICATION DATA FOR HAZARDOUS LOCATIONS L105
L
VM1/VM2 SERIES THERMAL PERFORMANCE DATA1
CLASS I ZONE 2 RESTRICTED BREATHING
LAMP
TYPE
HPS
HPS
HPS
HPS
MH
MH
MH
MHP
MHP
HPS
DESCRIPTION
LAMP
WATTAGE
50
70
100
150
50
70
100
150/125
175
35
AMBIENT
°C
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
VM1 SERIES**
GLOBE
ONLY
T5
T4
T4
T4
T4
T4
T3
T3
T3
T3
T6
T4
T4
T5
T4
T4
T4
T3
T3
T3
T3
T3
T6
T5
T5
GLOBE
W/ REFLECTOR
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T5
T4
T4
T5
T4
T4
T4
T3
T3
T3
T3
T3
T6
T5
T5
VM2 SERIES**
REFRACTOR
VMR
T5
T4
T4
T4
T4
T4
T3
T3
T3
T3
T6
T4
T4
T5
T4
T4
T4
T3
T3
T3
T3
T3
T6
T5
T5
GLOBE
ONLY
T5
T4
T4
T4
T4
T4
T3
T3
T3
T3
T5
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T3
T6
T5
T5
GLOBE
W/ REFLECTOR
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T5
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T3
T6
T5
T5
SUPPLY
WIRE °C
60
75
90
75
90
90
90
90
90
90
60
75
90
75
75
90
75
90
105
90
90
90
105
60
75
90
ENCLOSED REFLECTORS
VMER40
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T5
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T3
T6
T5
T5
VMEP40
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T5
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T3
T6
T5
T5
REFRACTOR
VMR
T5
T4
T4
T4
T4
T4
T3
T3
T3
T3
T5
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T3
T6
T5
T5
T-CODE & TEMPERATURE RANGE CONVERSION TABLE °C
T1
351-450
350
326-350
325
301-325
T2
281-300
T2A
261-280
T2B
231-260
T2C
216-230
T2D
201-215
T3
181-200
T3A
166-180
T3B
161-165
T3C
136-160
T4
121-135
T4A
101-120
T5
86-100
T6
<=85
1Data does not apply to luminaries with auxiliary quartz lighting; consult factory with requirements.
The suitability of these fixtures for Class I Zone 2 AEx nAR II locations must be determined for each
application based on NEC® Article 505.
** VM1 Series accepts 5-1/2" threaded optics; VM2 accepts 7-3/4" optics.
— Not available.
CERTILITE®V SERIES LIGHTING
APPLICATION DATA FOR HAZARDOUS LOCATIONS
L106
VM1/VM2 SERIES THERMAL PERFORMANCE DATA1
CLASS II DIVISIONS 1 & 2 GROUPS E,F,G & CLASS III*
LAMP
TYPE
HPS
HPS
HPS
HPS
HPS
MH
MH
MH
MHP
MHP
QL
DESCRIPTION
LAMP
WATTAGE
35
50
70
100
150
50
70
100
150/125
175
55
AMBIENT
°C
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
VM1 SERIES**
GLOBE
ONLY
T4A
T4
T4
T4A
T4
T4
T4A
T4
T4
T3C
T3C
T3C
T4A
T4
T3C
T4A
T4
T3C
T4
T3C
T3C
T3C
T3A
EFG
GLOBE
W/ REFLECTOR
T4A
T4
T4
T4A
T4
T4
T4A
T4
T4
T3C
T3C
T3C
T4A
T4
T3C
T4A
T4
T3C
T4
T3C
T3C
T3C
T3A
EFG
VM2 SERIES**
VMR
T4A
T4
T4
T4A
T4
T4
T4A
T4
T4
T3C
T3C
T3C
T4A
T4
T3C
T4A
T4
T3C
T4
T3C
T3C
T3C
T3A
EFG
REFRACTORS
VZRG 8"
T4A
T4
T4
T4A
T4
T4
T4A
T4
T4
T3C
T3C
T3C
T4A
T4
T3C
T4A
T4
T3C
T4
T3C
T3C
T3C
T3A
EFG
VZRG 12"
T4A
T4
T4
T4A
T4
T4
T4A
T4
T4
T3C
T3C
T3C
T4A
T4
T3C
T4A
T4
T3C
T4
T3C
T3C
T3C
T3A
EFG
GLOBE
ONLY
T6
T5
T4A
T6
T5
T5
T5
T4A
T4A
T4A
T4
T4
T3C
T5
T4A
T4A
T5
T4A
T4A
T4A
T4
T4
T4
T3C
T3C
T3C
GLOBE
W/ REFLECTOR
T6
T5
T4A
T6
T5
T4A
T5
T4A
T4A
T4A
T4
T4
T3C
T5
T4A
T4A
T5
T4A
T4A
T4A
T4
T4
T4
T3C
T3C
T3C
SUPPLY
WIRE °C
60
75
75
60
75
90
75
75
90
90
90
90
90
60
75
90
75
75
90
75
90
105
90
90
90
105
75
ENCLOSED REFLECTORS
VMER40
T6
T5
T4A
T6
T5
T4A
T5
T4A
T4A
T4A
T4
T4
T3C
T5
T4A
T4A
T5
T4A
T4A
T4A
T4
T4
T4
T3C
T3C
T3C
VMEP40
T6
T5
T4A
T6
T5
T4A
T5
T4A
T4A
T4A
T4
T4
T3C
T5
T4A
T4A
T5
T4A
T4A
T4A
T4
T4
T4
T3C
T3C
T3C
REFRACTOR
VMR
T6
T5
T4A
T6
T5
T4A
T5
T4A
T4A
T4A
T4
T4
T3C
T5
T4A
T4A
T5
T4A
T4A
T4A
T4
T4
T4
T3C
T3C
T3C
T-CODE & TEMPERATURE RANGE CONVERSION TABLE °C
T1
351-450
350
326-350
325
301-325
T2
281-300
T2A
261-280
T2B
231-260
T2C
216-230
T2D
201-215
T3
181-200
T3A
166-180
T3B
161-165
T3C
136-160
T4
121-135
T4A
101-120
T5
86-100
T6
<=85
1Data does not apply to luminaries with auxiliary quartz lighting; consult factory with requirements.
2Limit for E & F.
3Limit for G & Class III.
* Luminaries rated for Group G (=<165°C), T3B are also suitable for Class III applications; Luminaries rated for E & F ≤ 200°C (T3).
** VM1 Series accepts 5-1/2" threaded optics; VM2 accepts 7-3/4" optics.
— Not available.
23
CERTILITE®V SERIES LIGHTING
APPLICATION DATA FOR HAZARDOUS LOCATIONS L107
L
VM1/VM2 SERIES THERMAL PERFORMANCE DATA1 2
“SIMULTANEOUS PRESENCE" CLASS I DIVISION 2 (LAMP TEMPERATURE IN DUST CONDITIONS) & CLASS II DIVISION I
LAMP
TYPE
HPS
HPS
HPS
HPS
HPS
MH
MH
MH
MHP
MHP
DESCRIPTION
LAMP
WATTAGE
35
50
70
100
150
50
70
100
150/125
175
AMBIENT
°C
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
VM1 SERIES**
GLOBE
ONLY
T3A
T2C
T2B
T2A
325°C
T2B
T2B
T2
350°C
GLOBE
W/ REFLECTOR
T3A
T2C
T2B
T2A
325°C
T2B
T2B
T2
350°C
VM2 SERIES**
VMR
T3A
T2C
T2B
T2A
325°C
T2B
T2B
T2
350°C
REFRACTORS
VZRG 8"
T3A
T2C
T2B
T2A
325°C
T2B
T2B
T2
350°C
VZRG 12"
T3A
T2C
T2B
T2A
325°C
T2B
T2B
T2
350°C
GLOBE
ONLY
T2D
T2D
T2B
T2B
325°C
T2C
T2C
T2A
350°C
450°C
GLOBE
W/ REFLECTOR
T2D
T2D
T2B
T2B
325°C
T3C
T2C
T2A
350°C
450°C
SUPPLY
WIRE °C
60
60
75
75
90
75
75
90
90
90
ENCLOSED REFLECTORS
VMER40
T2D
T2D
T2B
T2B
325°C
T3C
T2C
T2A
350°C
450°C
VMEP40
T2D
T2D
T2B
T2B
325°C
T3C
T2C
T2A
350°C
450°C
REFRACTOR
VMR
T2D
T2D
T2B
T2B
325°C
T3C
T2C
T2A
350°C
450°C
T-CODE & TEMPERATURE RANGE CONVERSION TABLE °C
T1
351-450
350
326-350
325
301-325
T2
281-300
T2A
261-280
T2B
231-260
T2C
216-230
T2D
201-215
T3
181-200
T3A
166-180
T3B
161-165
T3C
136-160
T4
121-135
T4A
101-120
T5
86-100
T6
<=85
1Data does not apply to luminaries with auxiliary quartz lighting; consult factory with requirements.
2Table shows lamp temperature inside dust covered optic - see Class II table for Groups E, F, G and Class III data.
** VM1 Series accepts 5-1/2" threaded optics; VM2 accepts 7-3/4" optics.
— Not available.
CERTILITE®V SERIES LIGHTING
APPLICATION DATA FOR HAZARDOUS LOCATIONS
L108
VM3/VM4 SERIES THERMAL PERFORMANCE DATA1
CLASS I DIVISION 2 GROUPS A,B,C,D / ZONE 2 GROUPS IIC, IIB, IIA
LAMP
TYPE
HPS
HPS
HPS
HPS
MH
MH
MH
MH
MHP
MHP
QL
DESCRIPTION
LAMP
WATTAGE
50
70
100
150
70
100
175
250
125/150/175
200
85
AMBIENT
°C
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
VM3 SERIES**
GLOBE
ONLY
T3B
T3A
T3
T3
T3
T3
T2D
T2C
T2C
T2B
T2B
T3B
T3
T2D
T3
T3
T2D
T2A
T2
325°C
T2A
T2A
T2A
T2
GLOBE
W/ REFLECTOR
T3B
T3A
T3
T3
T3
T3
T2D
T2C
T2C
T2B
T2B
T3A
T3
T2D
T3
T3
T2D
T2A
T2
325°C
T2A
T2A
T2A
T2
VM4 SERIES**
VMR
T3B
T3A
T3
T3
T3
T3
T2D
T2C
T2C
T2B
T2B
T3B
T3
T2D
T3
T3
T2D
T2A
T2
325°C
T2A
T2A
T2A
T2
REFRACTORS
VZRG 8"
T3B
T3A
T3
T3
T3
T3
T2D
T2C
T2C
T2B
T2B
T3A
T3
T3
T3
T3
T2D
T2B
T2
T2
T2B
T2A
T2B
T2
VZRG 12"
T3B
T3A
T3
T3A
T3
T3
T3
T2C
T2C
T2B
T2B
T3C
T3
T3
T3A
T2D
T2D
T2B
T2
T2
T2B
T2A
T2B
T2
GLOBE
ONLY
T3C
T3B
T3
T3A
T3
T3
T3
T2D
T2C
T2B
T2B
T3C
T3C
T3A
T3A
T3
T3
T2B
T2A
T2
T2B
T2A
T2A
T2B
T2A
T3
GLOBE
W/ REFLECTOR
T3C
T3B
T3
T3A
T3A
T3
T3
T2D
T2C
T2B
T2B
T3C
T3B
T3A
T3
T3
T3
T2B
T2A
T2
T2B
T2A
T2A
T2B
T2A
T3
SUPPLY
WIRE °C
90
90
90
90
90
90
90
90
110
90
90
90
90
90
90
90
90
90
110
90
90
110
110
90
110
75
ENCLOSED REFLECTORS
VMER40
T3C
T3B
T3
T3A
T3
T3
T3
T2D
T2C
T2B
T2B
T3C
T3C
T3A
T3A
T3
T3
T2B
T2A
T2
T2B
T2A
T2A
T2B
T2A
T3
VMEP40
T3C
T3B
T3
T3A
T3
T3
T3
T2D
T2C
T2B
T2B
T3C
T3C
T3A
T3A
T3
T3
T2B
T2A
T2
T2B
T2A
T2A
T2B
T2A
T3
REFRACTOR
VMR
T3C
T3B
T3
T3A
T3
T3
T3
T2D
T2C
T2B
T2B
T3C
T3C
T3A
T3A
T3
T3
T2B
T2A
T2
T2B
T2A
T2A
T2B
T2A
T3
T-CODE & TEMPERATURE RANGE CONVERSION TABLE °C
T1
351-450
350
326-350
325
301-325
T2
281-300
T2A
261-280
T2B
231-260
T2C
216-230
T2D
201-215
T3
181-200
T3A
166-180
T3B
161-165
T3C
136-160
T4
121-135
T4A
101-120
T5
86-100
T6
<=85
1Data does not apply to luminaries with auxiliary quartz lighting; consult factory with requirements. The
suitability of these fixtures for Class I Division 2 / Zone 2 locations must be determined for each applica-
tion based on NEC® Articles 501.125(B) or 505.
** VM3 Series accepts 5-1/2" threaded optics; VM4 accepts 7-3/4" threaded optics.
— Not available.
CERTILITE®V SERIES LIGHTING
APPLICATION DATA FOR HAZARDOUS LOCATIONS
L
L109
VM3/VM4 SERIES THERMAL PERFORMANCE DATA1
CLASS I ZONE 2 RESTRICTED BREATHING
LAMP
TYPE
HPS
HPS
HPS
HPS
MH
MH
MH
MH
MHP
MHP
DESCRIPTION
LAMP
WATTAGE
50
70
100
150
70
100
175
250
150/175
200
AMBIENT
°C
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
VM3 SERIES**
GLOBE
ONLY
T6
T5
T4
T5
T5
T4
T5
T4
T4
T4
T3
T5
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T3
T3
GLOBE
W/ REFLECTOR
T6
T5
T4
T5
T5
T4
T5
T4
T4
T4
T3
T5
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T3
T3
VM4 SERIES**
REFRACTOR
VMR
T6
T5
T4
T5
T5
T4
T5
T4
T4
T4
T3
T5
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T3
T3
GLOBE
ONLY
T6
T6
T5
T6
T5
T5
T5
T5
T4
T4
T4
T5
T5
T4
T5
T5
T4
T4
T4
T3
T4
T4
T3
T4
T3
GLOBE
W/ REFLECTOR
T6
T6
T5
T6
T5
T5
T5
T5
T4
T4
T4
T6
T5
T4
T5
T4
T4
T4
T4
T3
T4
T4
T3
T4
T3
SUPPLY
WIRE °C
90
90
90
90
90
90
90
90
110
90
90
90
90
90
90
90
90
90
110
90
90
90
110
90
110
ENCLOSED REFLECTORS
VMER40
T6
T6
T5
T6
T5
T5
T5
T5
T4
T4
T4
T6
T5
T4
T5
T4
T4
T4
T4
T3
T4
T4
T3
T4
T3
VMEP40
T6
T6
T5
T6
T5
T5
T5
T5
T4
T4
T4
T6
T5
T4
T5
T4
T4
T4
T4
T3
T4
T4
T3
T4
T3
REFRACTOR
VMR
T6
T6
T5
T6
T5
T5
T5
T5
T4
T4
T4
T6
T5
T4
T5
T4
T4
T4
T4
T3
T4
T4
T3
T4
T3
T-CODE & TEMPERATURE RANGE CONVERSION TABLE °C
T1
351-450
350
326-350
325
301-325
T2
281-300
T2A
261-280
T2B
231-260
T2C
216-230
T2D
201-215
T3
181-200
T3A
166-180
T3B
161-165
T3C
136-160
T4
121-135
T4A
101-120
T5
86-100
T6
<=85
1Data does not apply to luminaries with auxiliary quartz lighting; consult factory with requirements.
The suitability of these fixtures for Class I Zone 2 AEx nAR II locations must be determined for each
application based on NEC® Article 505. Restricted breathing fixture with photo cell T3 only.
** VM3 Series accepts 5-1/2" threaded optics; VM4 accepts 7-3/4" threaded optics.
— Not available.
CERTILITE®V SERIES LIGHTING
APPLICATION DATA FOR HAZARDOUS LOCATIONS
L110
VM3/VM4 SERIES THERMAL PERFORMANCE DATA1
CLASS II DIVISIONS 1 & 2 GROUPS E,F,G & CLASS III*
LAMP
TYPE
HPS
HPS
HPS
HPS
MH
MH
MH
MH
MHP
MHP
QL
DESCRIPTION
LAMP
WATTAGE
50
70
100
150
70
100
175
250
150/175
200
85
AMBIENT
°C
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
VM3 SERIES**
GLOBE
ONLY
T3C
T3C
T3C
T3C
T3C
T3C
GLOBE
W/ REFLECTOR
T3C
T3C
T3C
T3C
T3C
T3C
VM4 SERIES**
VMR
T3C
T3C
T3C
T3C
T3C
T3C
REFRACTORS
VZRG 8"
T3C
T3C
T3C
T3C
T3C
T3C
VZRG 12"
T3C
T3C
T3C
T3C
T3C
T3C
GLOBE
ONLY
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
GLOBE
W/ REFLECTOR
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
SUPPLY
WIRE °C
90
90
90
90
90
90
90
90
90
90
75
ENCLOSED REFLECTORS
VMER40
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T4
VMEP40
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T4
REFRACTOR
VMR
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T3B
T-CODE & TEMPERATURE RANGE CONVERSION TABLE °C
T1
351-450
350
326-350
325
301-325
T2
281-300
T2A
261-280
T2B
231-260
T2C
216-230
T2D
201-215
T3
181-200
T3A
166-180
T3B
161-165
T3C
136-160
T4
121-135
T4A
101-120
T5
86-100
T6
<=85
1Data does not apply to luminaries with auxiliary quartz lighting; consult factory with requirements.
2Limit for E & F.
3Limit for G & Class III.
* Luminaries rated for Group G (=<165°C), T3B are also suitable for Class III applications; Luminaries
rated for E & F ≤ 200°C (T3).
** VM3 Series accepts 5-1/2" threaded optics; VM4 accepts 7-3/4" optics.
— Not available.
23
CERTILITE®V SERIES LIGHTING
APPLICATION DATA FOR HAZARDOUS LOCATIONS L111
L
VM3/VM4 SERIES THERMAL PERFORMANCE DATA1 2
“SIMULTANEOUS PRESENCE” CLASS I DIVISION 2 (LAMP TEMPERATURE IN DUST CONDITIONS) & CLASS II DIVISION I
LAMP
TYPE
HPS
HPS
HPS
HPS
MH
MH
MH
MH
MHP
MHP
DESCRIPTION
LAMP
WATTAGE
50
70
100
150
70
100
175
250
150/175
200
AMBIENT
°C
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
VM3 SERIES**
GLOBE
ONLY
T3
T3
T2C
T2A
T3A
T2D
GLOBE
W/ REFLECTOR
T2D
T2D
T2C
T2A
T3A
T2D
VM4 SERIES**
VMR
T3
T3
T2C
T2A
T3A
T2D
REFRACTORS
VZRG 8"
T3
T3
T2C
T2A
T3A
T2D
VZRG 12"
T3
T3
T2C
T2A
T3A
T2D
GLOBE
ONLY
T3B
T3
T2D
T2B
T3C
T3
T2A
325°C
T2A
T2A
GLOBE
W/ REFLECTOR
T3A
T3
T2D
T2B
T3B
T3
T2A
325°C
T2A
T2A
SUPPLY
WIRE °C
90
90
90
90
90
90
90
90
90
90
ENCLOSED REFLECTORS
VMER40
T3A
T3
T2D
T2B
T3C
T3
T2A
325°C
T2A
T2A
VMEP40
T3A
T3A
T3
T2B
T3C
T3
T2A
325°C
T2A
T2A
REFRACTOR
VMR
T3B
T3
T2D
T2B
T3C
T3
T2A
325°C
T2A
T2A
T-CODE & TEMPERATURE RANGE CONVERSION TABLE °C
T1
351-450
350
326-350
325
301-325
T2
281-300
T2A
261-280
T2B
231-260
T2C
216-230
T2D
201-215
T3
181-200
T3A
166-180
T3B
161-165
T3C
136-160
T4
121-135
T4A
101-120
T5
86-100
T6
<=85
1Data does not apply to luminaries with auxiliary quartz lighting; consult factory with requirements.
2Table shows lamp temperature inside dust covered optic - see Class II table for Groups E, F, G and
Class III data.
** VM3 Series accepts 5-1/2" threaded optics; VM4 accepts 7-3/4" optics.
— Not available.
CERTILITE®V SERIES LIGHTING
APPLICATION DATA FOR HAZARDOUS LOCATIONS
L112
VM5 SERIES THERMAL PERFORMANCE DATA1
LAMP
TYPE
HPS
HPS
HPS
HPS
MH
MH
MHP
MHP
MHP
MHP
QL
DESCRIPTION
LAMP
WATTAGE
200
250
400
600
250
400
250
320
350
400
165
3
AMBIENT
°C
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
CLASS I DIVISION 2 GROUPS A, B, C, D / ZONE 2 GROUPS IIC, IIB, IIA
GLOBE
ONLY
325°C
350°C
325°C
350°C
350°C
350°C
450°C
T2
T2
T2B
T2A
T2B
T2A
T2A
T2A
T2
T2A
T2
T3
GLOBE
W/ REFLECTOR
325°C
350°C
325°C
350°C
350°C
450°C
325°C
325°C
T2B
T2A
T2B
T2A
T2A
T2
T2A
T2
T3
CLASS I ZONE 2, “RESTRICTED BREATHING”2
REFRACTOR
VZRG 12"
325°C
350°C
325°C
350°C
350°C
350°C
450°C
T2
T2
T2B
T2A
T2B
T2A
T2A
T2A
T2A
T2A
T2A
T3
ENCLOSED REFLECTORS
VMER40
T2
325°C
T2
325°C
325°C
350°C
450°C
450°C
450°C
T2
T2
T2B
T2B
T2B
T2B
T2A
T2B
T2A
T2B
T2A
T3A
VMEP40
T2
325°C
T2
325°C
325°C
350°C
450°C
450°C
450°C
T2
T2
T2B
T2B
T2B
T2B
T2A
T2B
T2A
T2B
T2A
T3A
GLOBE
ONLY
T3
T3
T3
T3
T3
T3
T3
T3
T3
T4
T3
T4
T3
T3
T3
T3
T3
T3
T6
GLOBE
W/ REFLECTOR
T3
T3
T3
T3
T3
T3
T3
T3
T4
T3
T4
T3
T3
T3
T3
T3
T5
SUPPLY
WIRE °C
90
125
90
125
125
90
125
90
125
90
90
90
90
90
90
125
90
125
90
125
75
ENCLOSED REFLECTORS
VMER40
T4
T3
T4
T3
T4
T3
T3
T3
T3
T3
T3
T4
T3
T4
T3
T3
T4
T3
T4
T3
T6
VMEP40
T4
T3
T4
T3
T4
T3
T3
T3
T3
T3
T3
T4
T3
T4
T3
T3
T4
T3
T4
T3
T6
T-CODE & TEMPERATURE RANGE CONVERSION TABLE °C
T1
351-450
350
326-350
325
301-325
T2
281-300
T2A
261-280
T2B
231-260
T2C
216-230
T2D
201-215
T3
181-200
T3A
166-180
T3B
161-165
T3C
136-160
T4
121-135
T4A
101-120
T5
86-100
T6
<=85
1Data does not apply to luminaries with auxiliary quartz lighting; consult factory with requirements.
The suitability of these fixtures for Class I Zone 2 AEx nAR II locations must be determined for each application
based on NEC®Article 505. Restricted breathing fixture with photo cell T3 only.
2See L50 for Restricted Breathing Information.
3VM5Q uses VM4 optics including VMG25 and VMR25x all glass refractors.
— Not available
CERTILITE®V SERIES LIGHTING
APPLICATION DATA FOR HAZARDOUS LOCATIONS L113
L
VM5 SERIES THERMAL PERFORMANCE DATA1 2
LAMP
TYPE
HPS
HPS
HPS
MH
MH
MHP
MHP
MHP
MHP
QL
DESCRIPTION
LAMP
WATTAGE
200
250
400
250
400
250
320
350
400
165
5
AMBIENT
°C
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
CLASS II DIVISION 1 & 2 GROUPS E,F,G & CLASS III*
GLOBE
ONLY
T3C
T3C
T3B
T3C
GLOBE
W/ REFLECTOR
T3C
T3C
T3B
T3C
SIMULTANEOUS PRESENCE2LAMP TEMP. IN DUST CONDITIONS
REFRACTOR
VZRG 12"
T4A
T4
T4A
T4
T4
T4
T3C
T4
T4
T4
T4
T4
T3C
T4
T3C
T4
T3C
T3C
ENCLOSED REFLECTORS
VMER40
T4
T3C
T4
T3C
T3C
T4
T3B
T4
T4
T4
T4
T4
T3C
T4
T3C
T4
T3C
T3C
VMEP40
T4
T3C
T4
T3C
T3C
T4
T3B
T4
T4
T4
T4
T4
T3C
T4
T3C
T4
T3C
T3C
GLOBE
ONLY
350°C
350°C
T1
GLOBE
W/ REFLECTOR
350°C
350°C
T1
SUPPLY
WIRE °C
90
125
90
125
125
90
125
90
90
90
90
90
90
90
125
90
125
75
ENCLOSED REFLECTORS
VMER40
325°C
350°C
325°C
350°C
350°C
350°C
T1
325°C
325°C
T2B
T2A
T2B
T2A
T2A
T2
T2A
T2
VMEP40
325°C
350°C
325°C
350°C
350°C
350°C
T1
325°C
325°C
T2B
T2A
T2B
T2A
T2A
T2
T2A
T2
REFRACTOR
VZRG 12"
325°C
350°C
325°C
350°C
350°C
350°C
T1
325°C
325°C
T2B
T2A
T2B
T2A
T2A
T2
T2A
T2
T-CODE & TEMPERATURE RANGE CONVERSION TABLE °C
T1
351-450
350
326-350
325
301-325
T2
281-300
T2A
261-280
T2B
231-260
T2C
216-230
T2D
201-215
T3
181-200
T3A
166-180
T3B
161-165
T3C
136-160
T4
121-135
T4A
101-120
T5
86-100
T6
<=85
*** Table shows lamp temperature inside optic dust conditions, see Class II table for Groups E, F, G data.
1Data does not apply to luminaries with auxiliary quartz lighting; consult factory with requirements.
2Table shows lamp temperature inside dust covered optic - see Class II table for Groups E, F, G and Class III data.
3Limit for E & F.
4Limit for G & Class III.
5VM5Q uses VM4 optics including VMG25 and VMR25x all glass refractors.
* Luminares rated for Group G (=<165°C), T3B are also suitable for Class III applications; Luminaries rated for E & F ≤ 200°C (T3).
— Not available.
34
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA
L114
Test No. HPK09950
HIGH PRESSURE SODIUM-VM1, VM3
With Globe Only
35-150 Watt
Mogul Base
CANDLEPOWER 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 84.0%
ANGLE CP ANGLE CP
0227. 95.0 974.
5.0 175. 100.0 946.
10.0 152. 105.0 925.
15.0 255. 110.0 880.
20.0 391. 115.0 803.
25.0 284. 120.0 706.
30.0 390. 125.0 273.
35.0 542. 130.0 22.
40.0 662. 135.0 12.
45.0 687. 140.0 9.
50.0 744. 145.0 7.
55.0 788. 150.0 5.
60.0 843. 155.0 2.
65.0 887. 160.0 1.
70.0 941. 165.0 1.
75.0 968. 170.0 0.
80.0 994. 175.0 0.
85.0 1001. 180.0 0.
90.0 990.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .91 .91 .91 .91 .85 .85.85 .85 .74 .74 .74 .64.64 .64 .55 .55 .55 .50
1 .77 .71 .66 .61 .72 .66.61 .57 .56 .52 .49 .47.44 .42 .39 .37 .35 .30
2 .68 .59 .52 .45 .63 .55.48 .42 .46 .41 .36 .39.34 .31 .31 .28 .25 .21
3 .61 .50 .42 .35 .56 .46.39 .33 .39 .33 .28 .32.28 .23 .26 .22 .19 .16
4 .55 .43 .35 .28 .50 .40.32 .26 .33 .27 .22 .28.22 .18 .22 .18 .15 .11
5 .50 .37 .29 .23 .45 .35.27 .21 .29 .23 .18 .24.19 .15 .19 .15 .12 .09
6 .45 .33 .25 .19 .41 .30.23 .17 .26 .19 .15 .21.16 .12 .17 .13 .09 .07
7 .41 .29 .21 .16 .38 .27.20 .14 .23 .17 .12 .19.14 .10 .15 .11 .08 .05
8 .38 .26 .18 .13 .35 .24.17 .12 .20 .14 .10 .17.12 .08 .13 .09 .06 .04
9 .35 .23 .16 .11 .32 .22.15 .10 .18 .12 .08 .15 .10 .07 .12 .08 .05 .03
10 .32 .21 .14 .09 .30 .19.13 .08 .16 .11 .07 .13.09 .05 .11 .07 .04 .02
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 3.3
Test No. HPK09951
HIGH PRESSURE SODIUM-VM1, VM3
With Globe & Dome Reflector
35-150 Watt
Mogul Base
CANDLEPOWER – 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 66.7%
ANGLE CP ANGLE CP
01126. 95.0 25.
5.0 1067. 100.0 23.
10.0 1025. 105.0 43.
15.0 1127. 110.0 138.
20.0 1241. 115.0 132.
25.0 1113. 120.0 31.
30.0 1178. 125.0 11.
35.0 1286. 130.0 10.
40.0 1357. 135.0 9.
45.0 1334. 140.0 9.
50.0 1347. 145.0 8.
55.0 1331. 150.0 7.
60.0 1325. 155.0 6.
65.0 1295. 160.0 6.
70.0 1233. 165.0 5.
75.0 647. 170.0 5.
80.0 228. 175.0 5.
85.0 105. 180.0 5.
90.0 21.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .78 .78 .78 .78 .76 .76.76 .76 .72 .72 .72 .69.69 .69 .65 .65 .65 .64
1 .70 .67 .64 .61 .68 .65.62 .60 .62 .59 .57 .59.57 .55 .56 .54 .53 .51
2 .63 .57 .52 .48 .61 .56.51 .47 .53 .49 .46 .51.47 .45 .48 .46 .43 .42
3 .57 .49 .44 .39 .55 .48.43 .38 .46 .41 .37 .44.40 .36 .42 .38 .35 .34
4 .51 .43 .36 .31 .50 .41.36 .31 .39 .34 .30 .38.33 .29 .36 .32 .29 .27
5 .46 .37 .30 .26 .45 .36.30 .25 .34 .29 .25 .33.28 .24 .31 .27 .24 .22
6 .42 .33 .26 .22 .41 .32.26 .21 .30 .25 .21 .29.24 .21 .28 .24 .20 .19
7 .39 .29 .23 .18 .37 .28.22 .18 .27 .22 .18 .26.21 .17 .25 .20 .17 .16
8 .36 .26 .20 .15 .34 .25.19 .15 .24 .19 .15 .23.18 .15 .22 .18 .14 .13
9 .33 .23 .17 .13 .32 .23.17 .13 .22 .16 .13 .21.16 .13 .20 .16 .12 .11
10 .30 .20 .14 .11 .29 .20.14 .11 .19 .14 .10 .18.13 .10 .17 .13 .10 .09
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.8
Test No. HPK09952
HIGH PRESSURE SODIUM-VM1, VM3
With Globe & Angle Reflector
35-150 Watt
Mogul Base
CANDLEPOWER – 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 64.9%
Front Side
ANGLE CP ANGLE CP
01026. 01026.
5.0 985. 5.0 981.
15.0 1191. 15.0 995.
25.0 1210. 25.0 1019.
35.0 1503. 35.0 1200.
45.0 1585. 45.0 1296.
45.0 1719. 45.0 1337.
65.0 1681. 65.0 1219.
75.0 1626. 75.0 276.
85.0 1484. 85.0 61.
90.0 1377. 145.0 17.
95.0 1011. 95.0 13.
105.0 163. 105.0 10.
115.0 46. 115.0 10.
125.0 13. 125.0 9.
135.0 5. 135.0 8.
145.0 5. 145.0 7.
155.0 5. 155.0 5.
165.0 4. 165.0 4.
175.0 3. 175.0 3.
180.0 3. 180.0 3.
F ront
Side
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .76 .76 .76 .76. .74 .74 .74 .74 .69 .69 .69 .66.66 .66 .62 .62.62 .60
1 .67 .63 .59 .56 .65 .61.57 .54 .57 .54 .52 .54.51 .49 .51 .49.47 .45
2 .60 .54 .48 .44 .58 .52.47 .43 .49 .45 .41 .46.43 .40 .43 .41.38 .36
3 .54 .46 .40 .36 .52 .45.39 .35 .42 .38 .34 .40.36 .33 .38 .34.31 .30
4 .49 .40 .34 .29 .47 .39.33 .29 .37 .32 .28 .35.30 .27 .33 .29.26 .24
5 .45 .35 .29 .24 .43 .34.28 .24 .32 .27 .23 .31.26 .22 .29 .25.22 .20
6 .41 .31 .25 .21 .39 .31.25 .20 .29 .24 .20 .27.23 .19 .26 .22.19 .17
7 .38 .28 .22 .17 .36 .27 .21 .17 .26 .20 .17 .24.20 .16 .23 .19 .16 .14
8 .34 .25 .19 .15 .33.24.19 .15 .23 .18 .14 .22.17 .14 .21 .17 .13 .12
9 .32 .22 .17 .13 .31.22.16 .13 .21 .16 .12 .20.15 .12 .19 .15 .12 .10
10 .29 .20 .14 .10 .28.19 .14 .10 .18 .13 .10 .17.13 .10 .16 .12.09 .08
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.7
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA L115
L
Test No. HPK09954
HIGH PRESSURE SODIUM-VM1, VM3
With Type I All Glass Refractor
35-150 Watt
Mogul Base
CANDLEPOWER 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 86.2%
2683
1342
4025
5366
90˚
80˚
70˚
60˚
50˚
40˚30˚20˚10˚
180˚ 160˚ 150˚ 140˚ 130˚ 120˚
110˚
100˚
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .99 .99 .99 .99 .95 .95.95 .95 .87 .87 .87 .81.81 .81 .74 .74 .74 .71
1 .83 .76 .70 .64 .79 .72.67 .61 .66 .61 .57 .60.56 .52 .54 .51 .48 .45
2 .72 .61 .52 .44 .68 .58.49 .42 .52 .45 .39 .46.41 .36 .42 .37 .33 .30
3 .63 .50 .40 .32 .59 .47.38 .31 .42 .34 .28 .38.31 .26 .33 .28 .23 .20
4 .56 .42 .32 .24 .52 .40.30 .23 .35 .27 .21 .31.24 .19 .28 .22 .17 .14
5 .50 .36 .26 .19 .47 .34.25 .18 .30 .22 .16 .27.20 .14 .23 .18 .13 .10
6 .46 .31 .22 .15 .43 .30.21 .14 .26 .19 .13 .23.17 .11 .21 .15 .10 .08
7 .42 .28 .19 .12 .39 .26.18 .12 .23 .16 .10 .21.14 .09 .18 .13 .08 .06
8 .39 .25 .16 .10 .36 .24.15 .10 .21 .14 .09 .19.12 .08 .17 .11 .07 .05
9 .36 .23 .14 .09 .34 .21.14 .08 .19 .12 .07 .17.11 .07 .15 .10 .06 .04
10 .34 .21 .13 .08 .32 .20.12 .07 .18 .11 .06 .16.10 .06 .14 .09 .05 .03
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 6.76 90-270°
Test No. HPK09953
HIGH PRESSURE SODIUM-VM1, VM3
With Type V All Glass Refractor
35-150 Watt
Mogul Base
CANDLEPOWER – 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 81.7%
ANGLE CP ANGLE CP
0519. 95.0 550.
5.0 354. 100.0 418.
10.0 307. 105.0 349.
15.0 358. 110.0 312.
20.0 467. 115.0 279.
25.0 446. 120.0 247.
30.0 370. 125.0 168.
35.0 340. 130.0 117.
40.0 343. 135.0 75.
45.0 450. 140.0 45.
50.0 676. 145.0 25.
55.0 1092. 150.0 7.
60.0 1760. 155.0 2.
65.0 1958. 160.0 1.
70.0 1857. 165.0 1.
75.0 1377. 170.0 0.
80.0 995. 175.0 0.
85.0 858. 180.0 0.
90.0 711.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .93 .93 .93 .93 .89 .89.89 .89 .81 .81 .81 .75.75 .75 .68 .68 .68 .65
1 .78 .72 .66 .61 .74 .68.63 .58 .62 .58 .54 .56.52 .49 .50 .48 .45 .42
2 .68 .58 .50 .43 .64 .55.48 .41 .49 .43 .38 .44.39 .35 .39 .35 .32 .29
3 .60 .48 .39 .32 .56 .45.37 .30 .40 .33 .28 .36.30 .25 .32 .27 .23 .20
4 .53 .40 .30 .23 .49 .38.29 .22 .33 .26 .20 .29.23 .19 .26 .21 .16 .13
5 .47 .34 .25 .18 .44 .32.23 .17 .28 .21 .15 .25.19 .14 .22 .16 .12 .09
6 .43 .30 .21.14 .40 .28.20 .14 .25 .18 .12 .22.16 .11 .19 .14 .10 .07
7 .40 .26 .18 .12 .37 .25.17 .11 .22 .15 .10 .20.13 .09 .17 .12 .08 .06
8 .36 .24 .16 .10 .34 .22.15 .09 .20 .13 .08 .18 .12 .07 .15 .10 .06 .04
9 .34 .22 .14 .09 .32 .20.13 .08 .18 .12 .07 .16.11 .07 .14 .09 .06 .04
10 .32 .20 .12 .07 .30 .19 .12 .07 .17 .11 .06 .15.09 .06 .13 .08 .05 .03
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.1
Test No. HPK09483
HIGH PRESSURE SODIUM-VM1, VM3
With Type II 12" Spin-Top Refractor
35-150 Watt
Mogul Base
CANDLEPOWER 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 64.9%
Front Side
ANGLE CP ANGLE CP
01504. 85.0
707
.
5.0
1329
.90.0
643
.
15.0
1094
.95.0
572
.
25.0
1057
.105.0
369
.
35.0
1306
.115.0
349
.
45.0
2230
.125.0
400
.
55.0
2482
.135.0
342
.
60.0
2089
.145.0
273
.
65.0
1477
.155.0
182
.
70.0
1148
.165.0
64
.
75.0
925
.175.0
0.
80.0
798
.180.0
0.
1241
1862
2482
90˚
80˚
70˚
60˚
50˚
40˚30˚20˚10˚
180˚ 160˚ 150˚ 140˚ 130˚ 120˚
110˚
100˚
621
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .84 .84 .84 .84 .80 .80.80 .80 .73 .73 .73 .66.66 .66 .60 .60 .60 .57
1 .75 .70 .66 .62 .71 .67.63 .60 .60 .57 .55 .54.52 .50 .49 .47 .45 .42
2 .67 .59 .53 .48 .63 .56.51 .46 .51 .46 .43 .46.42 .39 .41 .38 .36 .33
3 .60 .51 .44 .39 .56 .48.42 .37 .43 .38 .34 .39.35 .31 .35 .31 .29 .26
4 .54 .44 .37 .31 .51 .42.35 .30 .38 .32 .28 .34.29 .25 .30 .26 .23 .21
5 .49 .39 .31 .26 .46 .37.30 .25 .33 .27 .23 .30.25 .21 .26 .22 .19 .17
6 .45 .34 .27 .22 .42 .32.26 .21 .29 .23 .19 .26.21 .18 .23 .19 .16 .14
7 .41 .30 .23 .18 .39 .29.22 .18 .26 .20 .16 .23.19 .15 .21 .17 .14 .12
8 .38 .27 .20 .16 .36 .26.20 .15 .23 .18 .14 .21.16 .13 .19 .15 .12 .10
9 .35 .25 .18 .14 .33 .23.17 .13 .21 .16 .12 .19 .15 .11 .17 .13 .10 .09
10 .33 .22 .16 .12 .31 .21.16 .12 .19 .14 .11 .18.13 .10 .16 .12 .09 .08
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.36 0 -180°
ANGLE CP ANGLE CP
0213.
5250.
15 533.
25 506.
35 457.
45 839.
55 2742.
60 4365.
65 5265.
70 5304.
75 4269.
80 3162.
85 2652.
90 1969.
95 1301.
105 763.
115 602.
125 294.
135 107.
145 32.
155 3.
165 1.
175 0.
180 0.
Angle Vertical
CP 90° Horizontal
Angle Vertical
CP 75° Horizontal
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA
L116
Test No. HPK09472
HIGH PRESSURE SODIUM-VM1, VM3
With Type V 8" Spin-Top Refractor
35-150 Watt
Mogul Base
CANDLEPOWER 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 69.1%
ANGLE CP ANGLE CP
01160. 95.0 312.
5.0 986. 100.0 258.
10.0 827. 105.0 204.
15.0 761. 110.0 169.
20.0 739. 115.0 149.
25.0 731. 120.0 136.
30.0 739. 125.0 135.
35.0 753. 130.0 133.
40.0 821. 135.0 123.
45.0 950. 140.0 109.
50.0 1366. 145.0 86.
55.0 1684. 150.0 59.
60.0 1595. 155.0 31.
65.0 1067. 160.0 5.
70.0 696. 165.0 1.
75.0 597. 170.0 0.
80.0 527. 175.0 0.
85.0 447. 180.0 0.
90.0 372.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .79 .79 .79 .79 .76 .76.76 .76 .71 .71 .71 .65.65 .65 .61 .61 .61 .58
1 .70 .66 .62 .59 .67 .63 .60 .57 .58 .56 .53 .54.52 .50 .50 .48 .46 .44
2 .63 .56 .50 .46 .60 .54 .48 .44 .49 .45 .42 .45.42 .39 .42 .39 .37 .34
3 .56 .48 .41 .36 .53 .46 .40 .35 .42 .37 .33 .39.34 .31 .36 .32 .29 .27
4 .51 .41 .34 .29 .48 .39 .33 .28 .36 .31 .27 .33.29 .25 .31 .27 .24 .22
5 .46 .35 .28 .23 .43 .34 .28 .23 .31 .26 .21 .29.24 .20 .26 .22 .19 .17
6 .41 .31 .24 .19 .39 .29.23 .18 .27 .21 .17 .25.20 .16 .23 .19 .15 .14
7 .37 .27 .20 .15 .35 .26.19 .15 .23 .18 .14 .22.17 .13 .20 .15 .12 .10
8 .34 .24 .17 .13 .32 .23 .17 .12 .21 .16 .12 .19.15 .11 .18 .14 .10 .09
9 .32 .21 .15 .11 .30 .21.15 .11 .19 .14 .10 .17 .13 .09 .16 .12 .09 .07
10 .29 .19 .13 .09 .28 .19 .13 .09 .17 .12 .09 .16.11 .08 .15 .11 .08 .06
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 0.8
Test No. HPK09479
HIGH PRESSURE SODIUM-VM1, VM3
With Type V 12" Spin-Top Refractor
35-150 Watt
Mogul Base
CANDLEPOWER – 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 78.4%
ANGLE CP ANGLE CP
01555. 95.0 316.
5.0 1437. 100.0 258.
10.0 1254. 105.0 214.
15.0 1106. 110.0 213.
20.0 1045. 115.0 254.
25.0 1005. 120.0 268.
30.0 1212. 125.0 226.
35.0 1108. 130.0 179.
40.0 1291. 135.0 155.
45.0 1346. 140.0 133.
50.0 1449. 145.0 109.
55.0 1474. 150.0 80.
60.0 1414. 155.0 53.
65.0 1189. 160.0 27.
70.0 827. 165.0 9.
75.0 576. 170.0 0.
80.0 464. 175.0 0.
85.0 398. 180.0 0.
90.0 357.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .90 .90 .90 .90 .87 .87.87 .87 .80 .80 .80 .74 .74 .74 .68 .68 .68 .65
1 .80 .76 .72 .68 .77 .73.69 .66 .67 .64 .61 .62.59 .57 .57 .55 .53 .50
2 .72 .65 .59 .54 .69 .62.57 .52 .57 .53 .49 .53.49 .46 .49 .46 .43 .41
3 .65 .56 .49 .44 .62 .54.48 .42 .50 .44 .40 .46.41 .38 .42 .30 .35 .33
4 .59 .49 .41 .35 .56 .47.40 .34 .43 .37 .33 .40.35 .31 .36 .32 .29 .27
5 .53 .42 .35 .29 .51 .41.34 .28 .38 .31 .27 .35.29 .25 .32 .27 .24 .22
6 .49 .37 .30 .25 .46 .36.29 .24 .33 .27 .23 .31.25 .21 .28 .24 .20 .18
7 .45 .33 .26 .21 .42 .32.25 .20 .29 .23 .19 .27.22 .18 .25 .20 .17 .15
8 .41 .29 .22 .17 .39 .28 .22 .17 .26 .20 .16 .24.19 .15 .22 .18 .14 .13
9 .38 .27 .20 .15 .36 .26 .19 .15 .24 .18 .14 .22.17 .13 .20 .16 .12 .11
10 .35 .23 .27 .12 .33 .23.16 .12 .21 .15 .11 .19.14 .11 .18 .13 .10 .09
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 0.9
Test No. HPK09478
HIGH PRESSURE SODIUM-VM1, VM3
With Type V 12" Spin-Top Poly
Refractor
35-150 Watt
Mogul Base
CANDLEPOWER 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 70.6%
ANGLE CP ANGLE CP
0829. 95.0 267.
5.0 810. 100.0 239.
10.0 874. 105.0 202.
15.0 901. 110.0 181.
20.0 887. 115.0 165.
25.0 864. 120.0 145.
30.0 815. 125.0 123.
35.0 863. 130.0 102.
40.0 956. 135.0 84.
45.0 1370. 140.0 68.
50.0 2123. 145.0 51.
55.0 2162. 150.0 34.
60.0 1438. 155.0 19.
65.0 823. 160.0 6.
70.0 .556 165.0 1.
75.0 407. 170.0 0.
80.0 319. 175.0 0.
85.0 275. 180.0 0.
90.0 265.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .82 .82 .82 .82 .79.79.79 .79 .73 .73 .73 .68.68 .68 .63 .63 .63 .61
1 .73 .70 .66 .63 .70.67.64 .61 .62 .60 .57 .58.56 .54 .54 .52 .51 .49
2 .66 .60 .55 .50 .63.58.53 .49 .54 .50 .46 .50.47 .44 .47 .44 .42 .40
3 .60 .52 .46 .41 .57.50.44 .40 .47 .42 .38 .43.39 .36 .40 .37 .34 .32
4 .54 .45 .38 .33 .51.43.37 .32 .40 .35 .31 .37.33 .29 .35 .31 .28 .26
5 .49 .39 .32 .27 .46.37.31 .26 .35 .29 .25 .32.28 .24 .30 .26 .23 .21
6 .44 .34 .27 .22 .42.32.26 .21 .30 .25 .20 .28.23 .19 .26 .22 .19 .17
7 .40 .29 .22 .18 .38.28.22 .17 .26 .20 .16 .24.19 .16 .22 .18 .15 .13
8 .36 .25 .19 .14 .34.25.18 .14 .23 .17 .13 .21.16 .13 .20 .15 .12 .10
9 .33 .23 .17 .12 .32.22.16 .12 .21 .15 .11 .19 .14 .11 .18 .13 .10 .09
10 .30 .20 .14 .10 .29.19.14 .10 .18 .13 .09 .17.12 .09 .15 .11 .08 .07
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 2.8
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA L117
L
Test No. HPK10116
HIGH PRESSURE SODIUM-VM1, VM3
With Globe & Full Cutoff Deep White Reflector*
35-150 Watt
Mogul Base
CANDLEPOWER 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 65.2%
ANGLE CP ANGLE CP
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .75 .75 .75 .75 .74 .74 .74 .74 .70 .70 .70 .67 .67 .67 .65.65 .65 .63
1 .70 .67 .64 .62 .68 .65.63 .61 .63 .61 .59 60 .59 .57 .58 .57 .56 .54
2 .64 .60 .56 .53 .63 .58 .55 .52 .56 .53 .51 .54 .52 .50 .52.50 .49 .47
3 .59 .53 .49 .45 .58 .52 .48 .45 .51 .47 .44 .49 .46 .43 .47.45 .43 .41
4 .54 .48 .42 .39 .53 .47 .42 .38 .45 .41 .38 .44 .40 .37 .42.39 .37 .36
5 .50 .43 .37 .33 .49 .42 .37 .33 .41 .36 .33 .39 .36 .33 .38.35 .32 .31
6 .46 .38 .33 .29 .45 .38 .33 .29 .37 .32 .29 .36 .32 .29 .35.31 .28 .27
7 .43 .34 .29 .25 .42 .34 .29 .25 .33 .28 .25 .32 .28 .25 .31.28 .25 .24
8 .39 .31 .26 .22 .38 .31 .26 .22 .30 .25 .22 .29 .25 .22 .28.24 .22 .20
9 .36 .28 .23 .19 .35 .28.23 .19 .27 .22 .19 .26 .22 .19 .26.22 .19 .18
10 .33 .24 .19 .16 .32 .24.19 .16 .23 .19 .16 .23 .18 .16 .22 .18 .15 .14
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.5
*Values using Spacer Kit
Test No. HPK09935
Efficiency 81.0%
ANGLE CP ANGLE CP
0348. 95.0 1337.
5.0 297. 100.0 1306.
10.0 277. 105.0 1286.
15.0 411. 110.0 1269.
20.0 501. 115.0 1226.
25.0 430. 120.0 1128.
30.0 598. 125.0 616.
35.0 807. 130.0 56.
40.0 923. 135.0 20.
45.0 1007. 140.0 13.
50.0 1070. 145.0 10.
55.0 1120. 150.0 7.
60.0 1173. 155.0 3.
65.0 1235. 160.0 2.
70.0 1290. 165.0 2.
75.0 1327. 170.0 0.
80.0 1326. 175.0 0.
85.0 1328. 180.0 0.
90.0 1347.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .88 .88 .88 .88 .83 .83.83 .83 .72 .72 .72 .62.62 .62 .52 .52 .52 .48
1 .76 .70 .64 .60 .70 .65.60 .56 .55 .51 .48 .46.43 .41 .38 .36 .34 .30
2 .67 .58 .51 .45 .61 .54.47 .42 .45 .40 .36 .38.34 .30 .30 .27 .25 .21
3 .60 .49 .41 .35 .55 .46.38 .33 .38 .33 .28 .32.27 .23 .25 .22 .19 .15
4 .54 .42 .34 .28 .49 .39.32 .26 .33 .27 .22 .27.22 .18 .22 .18 .15 .11
5 .49 .37 .29 .23 .44 .34.27 .21 .29 .22 .18 .23.18 .15 .19 .15 .11 .09
6 .44 .33 .25 .19 .41 .30.23 .17 .25 .19 .15 .21.16 .12 .16 .12 .09 .07
7 .41 .29 .21 .16 .37 .27.20 .15 .22 .16 .12 .18.13 .10 .14 .11 .08 .05
8 .37 .26 .18 .13 .34 .24.17 .12 .20 .14 .10 .16.12 .08 .13 .09 .06 .04
9 .35 .23 .16 .11 .32 .21.15 .10 .18 .12 .09 .15.10 .07 .12 .08 .05 .03
10 .32 .21 .14 .09 .29 .19.13 .09 .16 .11 .05 .13.09 .05 .10 .07 .04 .02
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 3.0
Test No. HPK09936
Efficiency 63.7%
ANGLE CP ANGLE CP
01624. 95.0 37.
5.0 1566. 100.0 35.
10.0 1536. 105.0 47.
15.0 1652. 110.0 148.
20.0 1719. 115.0 212.
25.0 1606. 120.0 63.
30.0 1717. 125.0 15.
35.0 1856. 130.0 13.
40.0 1906. 135.0 12.
45.0 1920. 140.0 11.
50.0 1902. 145.0 11.
55.0 1879. 150.0 9.
60.0 1837. 155.0 8.
65.0 1783. 160.0 7.
70.0 1677. 165.0 7.
75.0 885. 170.0 6.
80.0 324. 175.0 6.
85.0 137. 180.0 7.
90.0 35.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .75 .75 .75.75 .73.73.73 .73 .69.69 .69 .66.66.66 .63 .63 .63 .61
1 .68 .64 .61.59 .66.63.60 .57 .59.57 .55 .57.55.53 .54 .52 .51 .49
2 . 61 .55 .51.47 .59.54 .50 .46 .51 .48 .44 .49.46.43 .46 .44 .42 .40
3 .55 .48 .42.38 .53.47.41 .37 .44.40 .36 .42.38.35 .40 .37 .34 .33
4 .50 .41 .35.30 .48.40.34 .30 .38.33 .29 .36.32.29 .35 .31 .28 .26
5 .45 .36 .30.25 .43.35.29 .25 .33.28 .24 .32.27.24 .30 .26 .23 .22
6 .41 .32 .26.21 .40.31.25 .21 .30.24 .21 .28.24.20 .27 .23 .20 .18
7 .37 .28 .22 .18 .36.27 .22 .18 .26.21 .17 .25.20 .17 .24 .20 .17 .15
8 .34 .25 .19 .15 .33.24.19 .15 .23.18 .15 .22.18.14 .21 .17 .14 .13
9 .32 .22 .17 .13 .31.22.17 .13 .21.16 .13 .20.16.12 .19 .15 .12 .11
10 .29 .20 .14 .10 .28.19 .14 .10 .18 .14 .10 .18 .13 .10 .17 .13 .10 .09
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.8
METAL HALIDE, METAL HALIDE
PULSE-VM1, VM3
With Globe and Dome Reflector
50-250 Watt
Mogul Base
CANDLEPOWER 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH watt multiply by 0.64
For 250 MH watt multiply by 1.46
For 150 MHP watt multiply by 1.00
For 175 MHP watt multiply by 1.25
For 200 MHP watt multiply by 1.50
METAL HALIDE, METAL HALIDE
PULSE-VM1, VM3
With Globe
50-250 Watt
Mogul Base
CANDLEPOWER – 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH watt multiply by 0.64
For 250 MH watt multiply by 1.46
For 150 MHP watt multiply by 1.00
For 175 MHP watt multiply by 1.25
For 200 MHP watt multiply by 1.50
01918.
5.0 1906.
10.0 1911.
15.0 1903.
20.0 1976.
25.0 1778.
30.0 1742.
35.0 1849.
40.0 1986.
45.0 1807.
50.0 1701.
55.0 1023.
60.0 757.
65.0 588.
70.0 438.
75.0 303.
80.0 181.
85.0 77.
90.0 0.
95.0 0.
100.0 0.
105.0 0.
110.0 0.
115.0 0.
120.0 0.
125.0 0.
130.0 0.
135.0 0.
140.0 0.
145.0 0.
150.0 0.
155.0 0.
160.0 0.
165.0 0.
170.0 0.
175.0 0.
180.0 0.
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA
L118
Test No. HPK09937 Test No. HPK09980 Test No. HPK09946
METAL HALIDE, METAL HALIDE
PULSE-VM1, VM3
With Globe and
Angle Reflector
50-250 Watt
Mogul Base
CANDLEPOWER 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH watt multiply by 0.64
For 250 MH watt multiply by 1.46
For 150 MHP watt multiply by 1.00
For 175 MHP watt multiply by 1.25
For 200 MHP watt multiply by 1.50
Efficiency 62.4%
Front Side
ANGLE CP ANGLE CP
0.0 1506. 0.0 1506.
5.0 1478. 5.0 1486.
15.0 1676. 15.0 1548.
25.0 1770. 25.0 1467.
35.0 2281. 35.0 1684.
45.0 2429. 45.0 1750.
55.0 2520. 55.0 1698.
65.0 2507. 65.0 1579.
75.0 2396. 75.0 409.
85.0 2149. 85.0 87.
90.0 1964. 90.0 24.
95.0 1523. 95.0 20.
105.0 240. 105.0 14.
115.0 64. 115.0 14.
125.0 18. 125.0 13.
135.0 6. 135.0 10.
145.0 6. 145.0 9.
155.0 6. 155.0 7.
165.0 5. 165.0 5.
175.0 4. 175.0 4.
180.0 4. 165.0 4.
1518
4554
6072
90˚
80˚
70˚
60˚
50˚
40˚30˚20˚10˚
180˚ 160˚ 150˚ 140˚ 130˚ 120˚
110˚
100˚
3036
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .73 .73 .73.73 .71.71.71 .71 .67.67 .67 .63.63.63 .60 .60 .60 .58
1 .65 .61 .57.54 .63.59.56 .53 .55.53 .50 .52.50.48 .49 .47 .46 .44
2 .58 .52 .47.43 .56.50.46 .42 .47.44 .40 .45.41.39 .42 .39 .37 .35
3 .53 .45 .39.35 .51.44.39 .34 .41.37 .33 .39.35.32 .37 .33 .31 .29
4 .48 .39 .33.29 .46.38.32 .28 .36.31 .27 .34.30.26 .32 .28 .25 .24
5 .44 .35 .28.24 .42.34.28 .23 .32.27 .23 .30.26.22 .28 .24 .21 .20
6 .40 .31 .25.20 .38 .30 .24 .20 .28.23 .19 .27.22 .19 .25 .21 .18 .17
7 .37 .27 .21.17 .35 .27.21 .17 .25 .20 .17 .24.19 .16 .23 .19 .16 .14
8 .34 .24 .19.15 .32 .24.18 .14 .22.18 .14 .21.17 .14 .20 .16 .13 .12
9 .31 .22 .16.13 .30 .21.16 .12 .20.15 .12 .19.15 .12 .18 .14 .12 .10
10 .28 .19 .14 .10 .27.19.14 .10 .18 .13 .10 .17.13 .10 .16 .12 .09 .08
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.7
METAL HALIDE, METAL HALIDE
PULSE-VM1, VM3
With Type I All
Glass Refractor
50-250 Watt
Mogul Base
CANDLEPOWER – 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH watt multiply by 0.64
For 250 MH watt multiply by 1.46
For 150 MHP watt multiply by 1.00
For 175 MHP watt multiply by 1.25
For 200 MHP watt multiply by 1.50
Efficiency 86.8%
ANGLE CP ANGLE CP
0433. 85.0 3813.
5.0 447. 90.0 3154.
15.0 703. 95.0 2185.
25.0 642. 105.0 1047.
35.0 598. 115.0 794.
45.0 1049. 125.0 389.
55.0 3738. 135.0 137.
60.0 5513. 145.0 40.
65.0 5774. 155.0 4.
70.0 6031. 165.0 2.
75.0 4991. 175.0 0.
80.0 4211. 180.0 0.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .99 .99 .99 .99 .95 .95.95 .95 .87 .87 .87 .80.80 .80 .73 .73 .73 .70
1 .83 .76 .69 .63 .79 .72.66 .61 .65 .60 .56 .58.54 .51 .52 .49 .46 .43
2 .72 .61 .52 .44 .67 .58.49 .42 .51 .44 .39 .46.40 .35 .40 .36 .32 .28
3 .63 .50 .40 .32 .59 .47.38 .31 .42 .34 .28 .37.31 .25 .32 .27 .22 .19
4 .56 .42 .32 .24 .52 .40.30 .23 .35 .27 .21 .31.24 .19 .27 .21 .17 .14
5 .51 .36 .26 .19 .47 .34 .25 .18 .30 .22 .16 .27.20 .14 .23 .17 .13 .10
6 .46 .32 .22 .15 .43 .30 .21 .15 .26 .19 .13 .23.17 .11 .20 .14 .10 .07
7 .42 .28 .19 .13 .39 .27.18 .12 .24 .16 .11 .21.14 .09 .18 .12 .08 .06
8 .39 .25 .17 .11 .37 .24.16 .10 .21 .14 .09 .19 .12 .08 .16 .11 .07 .05
9 .36 .23 .15 .09 .34 .22.14 .09 .19 .12 .08 .17.11 .07 .15 .10 .06 .04
10 .34 .21 .13 .08 .32 .20.12 .07 .18 .11 .07 .16 .10 .06 .14 .09 .05 .03
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 5.7 90-270°
METAL HALIDE, METAL HALIDE
PULSE-VM1, VM3
with Type V All
Glass Refractor
50-250 Watt
Mogul Base
CANDLEPOWER – 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH watt multiply by 0.64
For 250 MH watt multiply by 1.46
For 150 MHP watt multiply by 1.00
For 175 MHP watt multiply by 1.25
For 200 MHP watt multiply by 1.50
Efficiency 79.7%
ANGLE CP ANGLE CP
0731. 95.0 927.
5.0 562. 100.0 673.
10.0 489. 105.0 542.
15.0 542. 110.0 475.
20.0 640. 115.0 420.
25.0 592. 120.0 370.
30.0 519. 125.0 256.
35.0 498. 130.0 171.
40.0 491. 135.0 106.
45.0 641. 140.0 65.
50.0 921. 145.0 35.
55.0 1545. 150.0 9.
60.0 2543. 155.0 3.
65.0 2730. 160.0 1.
70.0 2320. 165.0 1.
75.0 1789. 170.0 0.
80.0 1509. 175.0 0.
85.0 1367. 180.0 0.
90.0 1186.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .90 .90 .90 .90 .86.86.86 .86 .79.79 .79 .72 .72.72 .66.66 .66 .63
1 .76 .70 .64 .59 .72 .66.61 .57 .60.56 .52 .54 .50 .47 .48.45 .43 .40
2 .66 .57 .49 .42 .62.54.46 .40 .48.42 .37 .43 .38.33 .38.34 .30 .27
3 .58 .47 .38 .31 .55.44.36 .30 .39.33 .27 .35 .29.24 .30.26 .22 .19
4 .52 .39 .30 .23 .48.37.29 .22 .33.25 .20 .29 .23 .18 .25.20 .16 .13
5 .46 .33 .24 .18 .43.31.23 .17 .28.20 .15 .24 .18 .13 .21.16 .12 .09
6 .42 .29 .21 .14 .39.28.20 .14 .24.17 .12 .21 .15 .11 .18 .13 .09 .07
7 .39 .26 .18 .12 .36.25.17 .11 .22.15 .10 .19 .13 .09 .16.11 .08 .05
8 .36 .23 .15 .10 .33.22 .15 .09 .19.13 .08 .17 .11 .07 .15 .10 .06 .04
9 .33 .21 .14 .09 .31.20.13 .08 .18.12 .07 .16 .10 .06 .14.09 .06 .04
10 .31 .19 .12 .08 .29.18 .12 .07 .16 .10 .06 .14 .09 .05 .13 .08 .05 .03
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.1
Angle Vertical
CP 90° Horizontal
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA L119
L
Test No. HPK09482 Test No. HPK09473 Test No. HPK09475
METAL HALIDE, METAL HALIDE
PULSE-VM1, VM3
With Type II 12" Spin-Top
Refractor
50-250 Watt
Mogul Base
CANDLEPOWER 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH watt multiply by 0.64
For 250 MH watt multiply by 1.46
For 150 MHP watt multiply by 1.00
For 175 MHP watt multiply by 1.25
For 200 MHP watt multiply by 1.50
Efficiency 75.1%
ANGLE CP ANGLE CP
1000
3000
4000
90˚
80˚
70˚
60˚
50˚
40˚30˚20˚10˚
180˚ 160˚ 150˚ 140˚ 130˚ 120˚
110˚
100˚
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .85 85 .85 .85 .81 .81.81 .81 .74 .74 .74 .67.67.67 .60 .60 .60 .57
1 .75 .71 .67.63 .71 .67.63 .60 .61.58 .55 .55.52.50 .49.47 .46 .43
2 .67 .60 .54.49 .63 .57.51 .47 .51.47 .43 .46.42.39 .41.38 .36 .33
3 .60 .51 .44.39 .57 .49.42 .37 .44.39 .34 .39.35.31 .35.32 .29 .26
4 .54 .44 .37.31 .51 .42.35 .30 .38.32 .28 .34.29.26 .30.27 .23 .21
5 .49 .39 .31 .26 .46 .37 .30 .25 .33.27 .23 .30 .25.21 .27 .23 .19 .17
6 .45 .34 .27 .22 .42 .33 .26 .21 .29.24 .19 .26 .22.18 .24 .19 .16 .14
7 .41 .31 .23 .19 .39 .29 .23 .18 .26.21 .16 .24 .19 .15 .21 .17 .14 .12
8 .38 .27 .21 .16 .36 .26 .20 .15 .24.18 .14 .21 .17 .13 .19 .15 .12 .10
9 .35 .25 .18 .14 .33 .24 .18 .13 .21.16 .12 .19 .15.11 .17 .13 .10 .09
10 .33 .23 .16 .12 .31 .22.16 .12 .20.14 .11 .18 .13.10 .16 .12 .09 .08
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.48 0 -180°
0.0 2111.
5.0 1908.
15.0 1598.
25.0 1521.
35.0 1810.
45.0 3016.
55.0 3608.
60.0 3065.
65.0 2257.
70.0 1712.
75.0 1367.
80.0 1182.
85.0 1076.
90.0 989.
95.0 888.
105.0 569.
115.0 522.
125.0 588.
135.0 498.
145.0 380.
155.0 239.
165.0 84.
175.0 0.
180.0 0.
METAL HALIDE, METAL HALIDE
PULSE-VM1, VM3
With Type V 8" Spin-Top
Refractor
50-250 Watt
Mogul Base
CANDLEPOWER – 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH watt multiply by 0.64
For 250 MH watt multiply by 1.46
For 150 MHP watt multiply by 1.00
For 175 MHP watt multiply by 1.25
For 200 MHP watt multiply by 1.50
Efficiency 70.2%
ANGLE CP ANGLE CP
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .81 .81 .81 .81 .78 .78.78 .78 .72 .72 .72 .66 .66 .66 .62.62 .62 .59
1 .71 .67 .63 .59 .68 .64 .61 .57 .59 .56 .54 .54 .52 .50 .50.48 .47 .44
2 .64 .57 .51 .46 .61 .54 .49 .45 .50 .46 .42 .46 .43 .40 .42.40 .37 .35
3 .57 .49 .42 .37 .54 .47 .41 .36 .43 .38 .34 .40 .35 .32 .36.33 .30 .28
4 .51 .42 .35 .29 .49 .40 .34 .29 .37 .31 .27 .34 .29 .25 .31.27 .24 .22
5 .46 .36 .29 .24 .44 .35.28 .23 .32 .26 .22 .29 .24 .21 .27.23 .19 .17
6 .42 .32 .25 .20 .40 .30.24 .19 .28 .22 .18 .26 .21 .17 .24.19 .16 .14
7 .38 .28 .21 .16 .36 .27.20.16 .24 .19 .15 .22 .17 .14 .21.16 .13 .11
8 .35 .24 .18 .13 .33 .23.17 .13 .22 .16 .12 .20 .15 .11 .18 .14 .11 .09
9 .32 .22 .16 .11 .31 .21 .15.11 .20 .14 .11 .18 .13 .10 .17.12 .09 .08
10 .30 .20 .14 .09 .28 .19 .13 .09 .17 .12 .09 .16 .11 .08 .15.11 .08 .06
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.0
0.0 1574.
5.0 1427.
10.0 1229.
15.0 1147.
20.0 1116.
25.0 1109.
30.0 1125.
35.0 1151.
40.0 1243.
45.0 1455.
50.0 2116.
55.0 2565.
60.0 2223.
65.0 1469.
70.0 1089.
75.0 930.
80.0 809.
85.0 672.
90.0 560.
95.0 475.
100.0 396.
105.0 313.
110.0 257.
115.0 226.
120.0 203.
125.0 200.
130.0 194.
135.0 179.
140.0 159.
145.0 127.
150.0 88.
155.0 46.
160.0 7.
165.0 2.
170.0 0.
175.0 0.
180.0 0.
METAL HALIDE, METAL HALIDE
PULSE-VM1, VM3
With Type V 12"
Spin-Top Refractor
50-250 Watt
Mogul Base
CANDLEPOWER – 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH watt multiply by 0.64
For 250 MH watt multiply by 1.46
For 150 MHP watt multiply by 1.00
For 175 MHP watt multiply by 1.25
For 200 MHP watt multiply by 1.50
Efficiency 78.8%
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .91 .91 .91 .91 .87 .87.87 .87 .81 .81 .81 .74 .74 .74 .69 .69 .69 .66
1 .81 .76 .72 .69 .77 .73.70 .66 .68 .65 .62 .62.60 .58 .57 .55 .54 .51
2 .73 .66 .59 .54 .70 .63.57 .53 .58 .53 .50 .53.50 .47 .49 .46 .44 .41
3 .66 .57 .50 .44 .63 .54.48 .43 .50 .45 .40 .46.42 .38 .43 .39 .36 .34
4 .59 .49 .41 .36 .56 .47.40 .35 .43 .38 .33 .40.35 .31 .37 .33 .29 .27
5 .54 .43 .35 .29 .51 .41.34 .29 .38 .32 .27 .35.30 .26 .32 .28 .24 .22
6 .49 .38 .30 .25 .47 .36.29 .24 .34 .27 .23 .31.26 .22 .29 .24 .20 .18
7 .45 .33 .26 .21 .43 .32.25 .20 .30 .24 .19 .27.22 .18 .25 .21 .17 .15
8 .41 .30 .22 .18 .39 .29.22 .17 .26 .20 .16 .24.19 .15 .23 .18 .15 .13
9 .38 .27 .20 .15 .36 .26.19 .15 .24 .18 .14 .22.17 .13 .20 .16 .13 .11
10 .35 .24 .17 .13 .33 .23.16 .12 .21 .15 .12 .20.14 .11 .18 .14 .10 .09
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - .9
ANGLE CP ANGLE CP
0.0 2261.
5.0 2146.
10.0 1868.
15.0 1657.
20.0 1555.
25.0 1502.
30.0 1534.
35.0 1664.
40.0 1857.
45.0 1970.
50.0 2168.
55.0 2205.
60.0 2104.
65.0 1809.
70.0 1176.
75.0 845.
80.0 696.
85.0 604.
90.0 517.
95.0 451.
100.0 380.
105.0 314.
110.0 305.
115.0 368.
120.0 391.
125.0 321.
130.0 260.
135.0 222.
140.0 191.
145.0 155.
150.0 115.
155.0 80.
160.0 41.
165.0 12.
170.0 0.
175.0 0.
180.0 0.
Angle Vertical
CP 75° Horizontal
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA
L120
Test No. HPK09477
METAL HALIDE, METAL HALIDE
PULSE-VM1, VM3
With Type V 12" Spin-
Top Poly Refractor
50-250 Watt
Mogul Base
CANDLEPOWER –
175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH watt multiply by 0.64
For 150 MHP watt multiply by 1.00
For 175 MHP watt multiply by 1.25
Efficiency 71.9%
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .83 .83 .83 .83 .80 .80.80 .80 .74 .74 .74 .69.69 .69 .64 .64 .64 .62
1 .74 .70 .67 .64 .71 .68.65 .62 .63 .60 .58 .58.56 .54 .54 .53 .51 .49
2 .67 .61 .55 .51 .64 .58.54 .49 .54 .50 .47 .50.47 .44 .47 .44 .42 .40
3 .61 .52 .46 .41 .58 .51.45 .40 .47 .42 .38 .44.40 .36 .41 .37 .35 .33
4 .54 .45 .38 .33 .52 .44.37 .32 .41 .35 .31 .38.33 .30 .35 .31 .28 .26
5 .49 .39 .32 .27 .47 .38.31 .26 .35 .30 .25 .33.28 .24 .30 .26 .23 .21
6 .45 .34 .27 .22 .42 .33.26 .22 .31 .25 .21 .28.24 .20 .26 .22 .19 .17
7 .40 .30 .23 .18 .38 .29.22 .18 .27 .21 .17 .25.20 .16 .23 .19 .15 .13
8 .37 .26 .19 .15 .35 .25.19 .14 .23 .18 .14 .22.17 .13 .20 .16 .12 .11
9 .34 .23 .17 .13 .32 .23.16 .12 .21 .16 .12 .19 .15 .11 .18 .14 .11 .09
10 .31 .21 .14 .10 .29 .20.14 .10 .18 .13 .09 .17.12 .09 .16 .12 .09 .07
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 2.6
Test No. HPK10118
METAL HALIDE, METAL HALIDE
PULSE-VM1, VM3
with Globe and Full
Cutoff Deep White
Reflector*
50-250 Watt
Mogul Base
CANDLEPOWER –
175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH watt multiply by 0.64
For 250 MH watt multiply by 1.46
For 150 MHP watt multiply by 1.00
For 175 MHP watt multiply by 1.25
For 200 MHP watt multiply by 1.50
Efficiency 65.5%
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .76 .76 .76 .76 .74 .74 .74 .74 .71 .71 .71 .68.68 .68 .65 .65 .65 .64
1 .70 .67 .65 .63 .68 .66.64 .62 .63 .61 .60 .61.59 .58 .58 .57 .56 .55
2 .65 .60 .56 .53 .63 .59.55 .52 .57 .54 .51 .55.52 .50 .53 .51 .49 .48
3 .60 .54 .49 .46 .58 .53.49 .45 .51 .48 .45 .49.46 .44 .48 .45 .43 .42
4 .55 .48 .43 .39 .54 .47.43 .39 .46 .42 .38 .44.41 .38 .43 .40 .37 .36
5 .51 .43 .38 .34 .49 .43.38 .34 .41 .37 .34 .40.36 .33 .39 .36 .33 .32
6 .47 .39 .34 .30 .46 .38.33 .30 .37 .33 .29 .36.32 .29 .35 .32 .29 .28
7 .43 .35 .30 .26 .42 .35.30 .26 .34 .29 .26 .33.29 .26 .32 .28 .25 .24
8 .40 .32 .26 .23 .39 .31.26 .23 .30 .26 .22 .29.25 .22 .29 .25 .22 .21
9 .37 .28 .23 .20 .36 .28.23 .20 .27 .23 .20 .27.23 .20 .26 .22 .19 .18
10 .33 .25 .20 .16 .32 .24.19 .16 .24 .19 .16 .23.19 .16 .23 .19 .16 .15
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.5
*Values using Dark Sky gasket kit
0.0 2879.
5.0 2911.
10.0 2938.
15.0 2913.
20.0 2914.
25.0 2678.
30.0 2648.
35.0 2810.
40.0 2926.
45.0 2682.
50.0 2492.
55.0 1443.
60.0 1107.
65.0 849.
70.0 637.
75.0 442.
80.0 265.
85.0 110.
90.0 0.
95.0 0.
100.0 0.
105.0 0.
110.0 0.
115.0 0.
120.0 0.
125.0 0.
130.0 0.
135.0 0.
140.0 0.
145.0 0.
150.0 0.
155.0 0.
160.0 0.
165.0 0.
170.0 0.
175.0 0.
180.0 0.
Test No. HPK09955
HIGH PRESSURE SODIUM-VM2,
VM4
With Globe
35-150 Watt
Mogul Base
CANDLEPOWER 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 84.6%
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .94 .94 .94 .94 .88 .88.88 .88 .78 .78 .78 .68.68 .68 .59 .59 .59 .55
1 .80 .74 .68 .63 .74 .69.64 .59 .59 .55 .52 .51.47 .45 .43 .40 .38 .34
2 .71 .61 .54 .47 .65 .57.50 .44 .49 .43 .38 .41.37 .33 .34 .31 .28 .24
3 .63 .52 .44 .37 .58 .48.41 .35 .41 .35 .30 .35.30 .26 .29 .25 .21 .18
4 .57 .45 .36 .29 .52 .42.34 .27 .36 .29 .24 .30.25 .20 .25 .20 .17 .14
5 .52 .39 .30 .24 .47 .36.28 .22 .31 .24 .19 .26.21 .16 .21 .17 .13 .11
6 .47 .34 .26 .20 .43 .32.24 .19 .27 .21 .16 .23.18 .13 .19 .14 .11 .08
7 .43 .30 .22 .17 .40 .28.21 .15 .24 .18 .13 .20.15 .11 .17 .12 .09 .07
8 .40 .27 .19 .14 .36 .25.18 .13 .22 .15 .11 .18.13 .09 .15 .11 .07 .05
9 .37 .24 .17 .12 .34 .23.16 .11 .19 .14 .09 .16 .11 .08 .13 .09 .06 .04
10 .34 .22 .15 .10 .31 .20.14 .09 .17 .12 .08 .14.10 .06 .12 .08 .05 .03
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.9
1346.
1290.
1380.
1389.
1365.
1319.
1264.
1342.
1436.
1961.
3177.
3107.
2035.
1273.
892.
643.
501.
430.
394.
398.
361.
306.
268.
247.
217.
182.
151.
124.
101.
77.
51.
29.
9.
2.
0.
0.
0.
614.
331.
265.
267.
325.
486.
501.
523.
599.
852.
903.
872.
849.
907.
970.
1006.
1026.
1036.
1035.
1007.
1004.
1035.
963.
649.
177.
37.
22.
15.
10.
8.
6.
4.
2
1.
0.
0.
0.
ANGLE CP ANGLE CP ANGLE CP ANGLE CP ANGLE CP ANGLE CP
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0 .
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA L121
L
Test No. HPK09956
HIGH PRESSURE SODIUM-VM2,
VM4
With Globe and
Dome Reflector
35-150 Watt
Mogul Base
CANDLEPOWER 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 66.5%
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .79 .79 .79 .79 .77 .77.77 .77 .73 .73 .73 .69.69 .69 .66 .66 .66 .64
1 .71 .68 .64 .61 .69 .66.63 .60 .62 .60 .58 .59.57 .56 .57 .55 .54 .52
2 .64 .58 .53 .49 .62 .57.52 .48 .54 .50 .47 .51.48 .45 .49 .46 .44 .42
3 .58 .50 .44 .39 .56 .49.43 .39 .46 .42 .38 .44.40 .37 .42 .39 .36 .34
4 .52 .43 .37 .32 .50 .42.36 .31 .40 .35 .31 .38.34 .30 .36 .33 .29 .28
5 .47 .38 .31 .26 .45 .37.31 .26 .35 .30 .25 .33.29 .25 .32 .28 .24 .23
6 .43 .33 .27 .22 .41 .32.26 .22 .31 .26 .21 .30.25 .21 .28 .24 .21 .19
7 .39 .29 .23 .19 .38 .29.23 .18 .27 .22 .18 .26.21 .18 .25 .21 .17 .16
8 .36 .26 .20 .16 .35 .26.20 .16 .24 .19 .15 .23.19 .15 .22 .18 .15 .13
9 .33 .23 .18 .13 .32 .23.17 .13 .22 .17 .13 .21.16 .13 .20 .16 .13 .11
10 .30 .20 .15 .11 .29 .20.14 .11 .19 .14 .11 .18.14 .10 .18 .13 .10 .09
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.3
1399.
1123.
1052.
1049.
1100.
1227.
1205.
1197.
1235.
1452.
1441.
1358.
1268.
1248.
1217.
643.
232.
110.
32.
33.
32.
52.
138.
119.
2.
21.
10.
9.
8.
8.
8.
7.
6.
5.
5.
5.
5.
Test No. HPK09957
HIGH PRESSURE SODIUM-VM2,
VM4
With Globe and
Angle Reflector
35-150 Watt
Mogul Base
CANDLEPOWER
100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 65.7%
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .78 .78 .78 .78 .76 .76.76 .76 .71 .71 .71 .67.67 .67 .63 .63 .63 .62
1 .69 .64 .61 .57 .66 .62.59 .56 .59 .56 .53 .55.53 .51 .52 .50 .48 .47
2 .62 .55 .50 .45 .59 .53.48 .44 .50 .46 .42 .47.44 .41 .45 .42 .39 .37
3 .56 .48 .42 .37 .54 .46.41 .36 .44 .39 .35 .41.37 .34 .39 .35 .32 .31
4 .50 .42 .35 .30 .49 .40.34 .30 .38 .33 .29 .36.31 .28 .34 .30 .27 .25
5 .46 .37 .30 .25 .44 .35.29 .25 .34 .28 .24 .32.27 .23 .30 .26 .23 .21
6 .42 .32 .26 .21 .41 .32.25 .21 .30 .25 .20 .28.24 .20 .27 .23 .19 .18
7 .39 .29 .23 .18 .37 .28.22 .18 .27 .21 .17 .25.20 .17 .24 .20 .16 .15
8 .35 .26 .20 .15 .34 .25.19 .15 .24 .19 .15 .23.18 .14 .21 .17 .14 .13
9 .33 .23 .17 .13 .32 .23.17 .13 .21 .16 .13 .20.16 .12 .19 .15 .12 .11
10 .30 .20 .14 .11 .29 .20.14 .10 .19 .14 .10 .18.13 .10 .17 .13 .10 .08
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.3
Front Side
ANGLE CP ANGLE CP
0.0 1312. 0.0 1312.
5.0 1131. 5.0 1060.
15.0 1124. 15.0 956.
25.0 1366. 25.0 1143.
35.0 1464. 35.0 1155.
45.0 1671. 45.0 1440.
55.0 1892. 55.0 1320.
65.0 2017. 65.0 1143.
75.0 1700. 75.0 339.
85.0 1372. 85.0 81.
90.0 1243. 90.0 30.
95.0 895. 95.0 20.
105.0 161. 105.0 12.
115.0 52. 115.0 10.
125.0 16. 125.0 10.
135.0 7. 135.0 8.
145.0 5. 145.0 6.
155.0 4. 155.0 5.
165.0 4. 165.0 4.
175.0 3. 175.0 3.
180.0 3. 165.0 3.
ANGLE CP ANGLE CP
Test No. HPK09960
HIGH PRESSURE SODIUM-VM2,
VM4
With Type I All
Glass Refractor
35-150 Watt
Mogul Base
CANDLEPOWER – 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 82.1%
2000
5000
8000
90˚
80˚
70˚
60˚
50˚
40˚30˚20˚10˚
180˚ 160˚ 150˚ 140˚ 130˚ 120˚
110˚
100˚
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .95 .95 .95 .95 .91 .91 .91 .91 .85 .85 .85 .79 .79 .79 .73 .73 .73 .71
1 .81 .74 .69 .63 .77 .71 .66 .61 .65 .61 .57 .60 .56 .53 .55 .52 .50 .47
2 .70 .60 .51 .44 .66 .57 .49 .43 .52 .45 .40 .47 .42 .37 .43 .38 .35 .32
3 .61 .49 .40 .32 .58 .47 .38 .31 .42 .35 .29 .38 .32 .27 .34 .29 .25 .22
4 .54 .41 .32 .24 .51 .39 .30 .23 .35 .28 .22 .32 .25 .20 .29 .23 .18 .16
5 .49 .35 .26 .19 .46 .34 .25 .18 .30 .23 .17 .27 .21 .15 .24 .19 .14 .12
6 .44 .31 .22 .15 .42 .29 .21 .15 .26 .19 .13 .24 .17 .12 .21 .16 .11 .09
7 .41 .27 .19 .12 .38 .26 .18 .12 .23 .16 .11 .21 .15 .10 .19 .13 .09 .07
8 .38 .24 .16 .10 .35 .23 .15 .10 .21 .14 .09 .19 .13 .08 .17 .12 .08 .06
9 .35 .22 .14 .09 .33 .21 .14 .09 .19 .13 .08 .17 .11 .07 .16 .10 .07 .05
10 .33 .20 .13 .08 .31 .19 .12 .07 .18 .11 .07 .16 .10 .06 .14 .09 .06 .04
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.64 90 -270°
ANGLE CP ANGLE CP
0806. 85.0 2161.
5.0 561. 90.0 1446.
15.0 517. 95.0 1037.
25.0 669. 105.0 592.
35.0 921. 115.0 399.
45.0 777. 125.0 192.
55.0 2076. 135.0 105.
60.0 4845. 145.0 89.
65.0 6434. 155.0 34.
70.0 6638. 165.0 1.
75.0 4655. 175.0 0.
80.0 2893. 180.0 0.
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0
Angle Vertical
CP 90° Horizontal
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA
L122
Test No. HPK09962
HIGH PRESSURE SODIUM-VM2, VM4
With Type III All Glass Refractor
35-150 Watt
Mogul Base
CANDLEPOWER 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 79.2%
1555
4665
6220
90˚
80˚
70˚
60˚
50˚
40˚30˚20˚10˚
180˚ 160˚ 150˚ 140˚ 130˚ 120˚
110˚
100˚
3110
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .91 .91 .91 .91 .88 .88.88 .88 .81 .81 .81 .75.75 .75 .70 .70 .70 .67
1 .78 .71 .66 .61 .74 .68.63 .59 .63 .58 .55 .57.54 .51 .52 .50 .47 .44
2 .67 .57 .49 .43 .63 .55.47 .41 .50 .43 .38 .45.40 .35 .41 .37 .33 .30
3 .59 .47 .38 .31 .55 .45.36 .30 .40 .33 .28 .36.31 .26 .33 .28 .24 .21
4 .52 .40 .30 .23 .49 .38.29 .22 .34 .27 .21 .30.24 .19 .27 .22 .17 .15
5 .47 .34 .25 .18 .44 .32.24 .18 .29 .22 .16 .26.20 .15 .23 .18 .13 .11
6 .43 .30 .21 .15 .40 .28.20 .14 .25 .18 .13 .23.17 .12 .20 .15 .11 .08
7 .39 .26 .18 .12 .37 .25.17 .12 .23 .16 .11 .20.14 .10 .18 .13 .09 .07
8 .36 .24 .16 .10 .34 .22.15 .10 .20 .14 .09 .18.12 .08 .16 .11 .07 .05
9 .34 .21 .14 .09 .32 .20.13 .08 .19 .12 .08 .17.11 .07 .15 .10 .06 .05
10 .31 .20 .12 .08 .30 .19.12 .07 .17 .11 .07 .15.10 .06 .14 .09 .06 .04
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 0.16 0-180°
ANGLE CP ANGLE CP
01341. 85.0 1905.
5.0 515. 90.0 1369.
15.0 670. 95.0 1002.
25.0 721. 105.0 610.
35.0 885. 115.0 507.
45.0 764. 125.0 235.
55.0 2033. 135.0 151.
60.0 4230. 145.0 123.
65.0 5791. 155.0 36.
70.0 6081. 165.0 1.
75.0 3906. 175.0 0.
80.0 2425. 180.0 0.
Test No. HPK09959
HIGH PRESSURE SODIUM-VM2, VM4
With Type V All Glass Refractor
35-150 Watt
Mogul Base
CANDLEPOWER – 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 77.1%
ANGLE CP ANGLE CP
0556. 95.0 338.
5.0 433. 100.0 262.
10.0 393. 105.0 196.
15.0 419. 110.0 184.
20.0 510. 115.0 174.
25.0 640. 120.0 152.
30.0 566. 125.0 134.
35.0 468. 130.0 113.
40.0 449. 135.0 101.
45.0 484. 140.0 86.
50.0 737. 145.0 75.
55.0 1105. 150.0 50.
60.0 2025. 155.0 18.
65.0 2255. 160.0 4.
70.0 1822. 165.0 1.
75.0 1107. 170.0 0.
80.0 767. 175.0 0.
85.0 612. 180.0 0.
90.0 458.
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .88 .88 .88 .88 .84 .84.84 .84 .78 .78 .78 .73.73 .73 .68 .68 .68 .65
1 .75 .70 .65 .60 .72 .67.62 .58 .61 .58 .54 .56.53 .51 .52 .49 .47 .45
2 .66 .57 .49 .43 .62 .54.48 .42 .50 .44 .39 .45.41 .37 .41 .38 .34 .32
3 .58 .47 .38 .32 .54 .45.37 .31 .41 .34 .29 .37.31 .27 .34 .29 .25 .23
4 .51 .39 .30 .23 .48 .37.29 .23 .34 .27 .21 .30.24 .20 .27 .22 .18 .16
5 .45 .33 .24 .18 .43 .31.23 .17 .28 .21 .16 .25.19 .15 .23 .18 .13 .11
6 .41 .29 .20 .14 .39 .27.20 .14 .25 .18 .13 .22.16 .12 .20 .15 .11 .09
7 .38 .26 .18 .12 .36 .24.17 .12 .22 .16 .11 .20.14 .10 .18 .13 .09 .07
8 .35 .23 .15 .10 .33 .22.15 .10 .20 .14 .09 .18.12 .08 .16 .11 .08 .06
9 .33 .21 .14 .09 .31 .20.13 .09 .18 .12 .08 .17.11 .07 .15 .10 .07 .05
10 .30 .19 .12 .08 .29 .18.12 .07 .17 .11 .07 .15.10 .06 .14 .09 .06 .04
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.4
Test No. HPK09958
HIGH PRESSURE SODIUM-VM2, VM4
With Enclosed Reflector
35-150 Watt
Mogul Base
CANDLEPOWER 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 66.1%
ANGLE CP ANGLE CP
04742. 95.0 0.
5.0 4454. 100.0 0.
10.0 5878. 105.0 0.
15.0 8942. 110.0 0.
20.0 8200. 115.0 0.
25.0 4433. 120.0 0.
30.0 1992. 125.0 0.
35.0 1141. 130.0 0.
40.0 881. 135.0 0.
45.0 769. 140.0 0.
50.0 156. 145.0 0.
55.0 49. 150.0 0.
60.0 27. 155.0 0.
65.0 16. 160.0 0.
70.0 10. 165.0 0.
75.0 6. 170.0 0.
80.0 4. 175.0 0.
85.0 2. 180.0 0.
90.0 0.
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .80 .80 .80 .80 .78 .78.78 .78 .75 .75 .75 .72.72 .72 .69 .69 .69 .67
1 .77 .76 .75 .74 .76 .75.73 .72 .72 .71 .70 .69.69 .68 .67 .67 .66 .65
2 .75 .73 .71 .69 .74 .72.70 .68 .70 .68 .67 .68.67 .66 .66 .65 .64 .63
3 .73 .70 .68 .66 .72 .69.67 .65 .68 .66 .64 .66.65 .63 .65 .63 .62 .62
4 .71 .67 .65 .63 .70 .67.64 .62 .65 .63 .62 .64.62 .61 .63 .62 .60 .60
5 .69 .65 .62 .60 .68 .64.62 .60 .63 .61 .59 .62.60 .59 .61 .60 .59 .58
6 .67 .63 .60 .58 .66 .62.60 .58 .61 .59 .58 .61.59 .57 .60 .58 .57 .56
7 .65 .61 .58 .56 .64 .60.58 .56 .60 .57 .56 .59.57 .55 .58 .56 .55 .54
8 .63 .59 .56 .54 .62 .58.56 .54 .58 .55 .54 .57.55 .53 .56 .55 .53 .53
9 .61 .56 .54 .52 .60 .56.53 .52 .56 .53 .52 .55.53 .51 .55 .53 .51 .51
10 .57 .52 .49 .47 .57 .52.49 .47 .52 .49 .47 .51.49 .47 .51 .49 .47 .46
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.0
Angle Vertical
CP 75° Horizontal
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA L123
L
Test No. HPK10125
HIGH PRESSURE SODIUM-VM2, VM4
With Globe & full Cutoff
Deep White Reflector*
35-150 Watt
Mogul Base
CANDLEPOWER 100 WATT
9500 lumens
For 35 watt multiply by 0.236
For 50 watt multiply by 0.42
For 70 watt multiply by 0.68
For 150 watt multiply by 1.68
Efficiency 64.4%
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .76 .76 .76 .76 .74 .74 .74 .74 .71 .71 .71 .68.68 .68 .65 .65 .65 .64
1 .70 .67 .65 .62 .68 .66.63 .61 .63 .61 .59 .61.59 .58 .58 .57 .56 .55
2 .65 .60 .56 .53 .63 .59.55 .52 .57 .54 .51 .54.52 .50 .53 .51 .49 .47
3 .60 .54 .49 .45 .58 .53.48 .45 .51 .47 .44 .49.46 .43 .48 .45 .43 .41
4 .55 .48 .43 .39 .53 .47.42 .39 .45 .41 .38 .44.40 .38 .43 .40 .37 .36
5 .50 .43 .38 .34 .49 .42.37 .33 .41 .36 .33 .40.36 .33 .38 .35 .32 .31
6 .47 .39 .33 .29 .45 .38.33 .29 .37 .32 .29 .36.32 .29 .35 .31 .29 .27
7 .43 .35 .29 .26 .42 .34.29 .25 .33 .29 .25 .32.28 .25 .31 .28 .25 .24
8 .40 .31 .26 .22 .39 .31.26 .22 .30 .25 .22 .29.25 .22 .28 .25 .22 .21
9 .36 .28 .23 .19 .36 .28.23 .19 .27 .22 .19 .26.22 .19 .26 .22 .19 .18
10 .33 .24 .19 .16 .32 .24.19 .16 .23 .19 .16 .23.18 .16 .22 .18 .15 .14
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.3
*Values using Dark Sky gasket kit
Test No. HPK09919
METAL HALIDE, METAL HALIDE PULSE-
VM2, VM4
With Globe
50-250 Watt
Mogul Base
CANDLEPOWER – 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH multiply by 0.64
For 250 MH multiply by 1.46
For 150 MHP multiply by 1.00
For 175 MHP multiply by 1.25
For 200 MHP multiply by 1.50
Efficiency 85.8%
ANGLE CP ANGLE CP
0741. 95.0 1439.
5.0 566. 100.0 1436.
10.0 466. 105.0 1501.
15.0 459. 110.0 1567.
20.0 521. 115.0 1273.
25.0 717. 120.0 435.
30.0 681. 125.0 87.
35.0 824. 130.0 39.
40.0 936. 135.0 27.
45.0 1289. 140.0 17.
50.0 1304. 145.0 13.
55.0 1231. 150.0 10.
60.0 1287. 155.0 7.
65.0 1359. 160.0 3.
70.0 1423. 165.0 2.
75.0 1457. 170.0 0.
80.0 1436. 175.0 0.
85.0 1423. 180.0 0.
90.0 1459.
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .95 .95 .95 .95 .89 .89.89 .89 .78 .78 .78 .68.68 .68 .59 .59 .59 .54
1 .81 .75 .70 .65 .75 .70.65 .60 .60 .56 .53 .51.48 .45 .43 .41 .38 .34
2 .72 .63 .55 .49 .66 .58.51 .45 .50 .44 .39 .42.38 .34 .35 .31 .28 .24
3 .65 .53 .45 .38 .59 .50.42 .36 .42 .36 .31 .35.30 .26 .29 .25 .22 .18
4 .58 .46 .37 .30 .53 .43.35 .28 .36 .30 .25 .30.25 .21 .25 .21 .17 .14
5 .53 .40 .31 .25 .48 .37.29 .23 .32 .25 .20 .26.21 .17 .22 .17 .14 .11
6 .48 .35 .27 .21 .44 .33.25 .19 .28 .21 .17 .23.18 .14 .19 .15 .11 .09
7 .44 .31 .23 .17 .40 .29.22 .16 .25 .18 .14 .21.15 .12 .17 .13 .09 .07
8 .40 .28 .20 .15 .37 .26.19 .14 .22 .16 .12 .18.13 .10 .15 .11 .08 .05
9 .37 .25 .18 .12 .34 .23.16 .12 .20 .14 .10 .17.12 .08 .14 .09 .06 .04
10 .34 .22 .15 .10 .32 .21.14 .10 .18 .12 .08 .15.10 .07 .12 .08 .05 .03
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 2.3
Test No. HPK09920
METAL HALIDE, METAL HALIDE PULSE-
VM2, VM4
With Globe &
Dome Reflector
50-250 Watt
Mogul Base
CANDLEPOWER 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH multiply by 0.64
For 250 MH multiply by 1.46
For 150 MHP multiply by 1.00
For 175 MHP multiply by 1.25
For 200 MHP multiply by 1.50
Efficiency 67.1%
ANGLE CP ANGLE CP
01925. 95.0 49.
5.0 1750. 100.0 46.
10.0 1644. 105.0 64.
15.0 1626. 110.0 199.
20.0 1667. 115.0 225.
25.0 1816. 120.0 38.
30.0 1725. 125.0 17.
35.0 1811. 130.0 14.
40.0 1877. 135.0 13.
45.0 2180. 140.0 11.
50.0 2115. 145.0 11.
55.0 1952. 150.0 10.
60.0 1893. 155.0 9.
65.0 1839. 160.0 8.
70.0 1753. 165.0 7.
75.0 950. 170.0 7.
80.0 348. 175.0 6.
85.0 153. 180.0 7.
90.0 52.
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .80 .80 .80 .80 .77 .77.77 .77 .73 .73 .73 .70.70 .70 .66 .66 .66 .65
1 .72 .68 .65 .62 .70 .66.63 .61 .63 .61 .58 .60.58 .56 .57 .55 .54 .52
2 .65 .59 .54 .49 .63 .57.52 .49 .54 .50 .47 .52.48 .46 .49 .46 .44 .42
3 .58 .51 .45 .40 .56 .49.44 .39 .47 .42 .38 .45.41 .37 .43 .39 .36 .35
4 .53 .44 .37 .32 .51 .43.37 .32 .41 .35 .31 .39.34 .30 .37 .33 .30 .28
5 .48 .38 .32 .27 .46 .37.31 .26 .35 .30 .26 .34.29 .25 .32 .28 .25 .23
6 .44 .34 .27 .23 .42 .33.27 .22 .31 .26 .22 .30.25 .21 .29 .24 .21 .19
7 .40 .30 .23 .19 .38 .29.23 .19 .28 .22 .18 .27.22 .18 .25 .21 .18 .16
8 .36 .24 .18 .14 .35 .26.20 .16 .25 .19 .16 .24.19 .15 .23 .18 .15 .14
9 .34 .24 .18 .14 .33 .23.18 .14 .22 .17 .13 .21.17 .13 .20 .16 .13 .12
10 .31 .21 .15 .11 .30 .20.15 .11 .19 .14 .11 .19 .14 .11 .18 .14 .10 .09
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.5
ANGLE CP ANGLE CP
02081.
5.0 863.
10.0 784.
15.0 1807.
20.0 1826.
25.0 1884.
30.0 1825.
35.0 1772.
40.0 1817.
45.0 1862.
50.0 1759.
55.0 1060.
60.0 736.
65.0 577
70.0 430.
75.0 298.
80.0 177.
85.0 75.
90.0 0.
95.0 0.
100.0 0.
105.0 0.
110.0 0.
115.0 0.
120.0 0.
125.0 0.
130.0 0.
135.0 0.
140.0 0.
145.0 0.
150.0 0.
155.0 0.
160.0 0.
165.0 0.
170.0 0.
175.0 0.
180.0 0.
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA
L124
Test No. HPK09921
METAL HALIDE, METAL HALIDE PULSE-
VM2, VM4
With Globe &
Angle Reflector
50-250 Watt
Mogul Base
CANDLEPOWER 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH multiply by 0.64
For 250 MH multiply by 1.46
For 150 MHP multiply by 1.00
For 175 MHP multiply by 1.25
For 200 MHP multiply by 1.50
Efficiency 65.0%
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .77 .77 .77 .77 .75 .75.75 .75 .70 .70 .70 .66.66 .66 .63 .63 .63 .61
1 .68 .64 .60 .57 .66 .62.59 .55 .58 .55 .53 .55.52 .50 .51 .50 .48 .46
2 .61 .55 .49 .45 .59 .53.48 .44 .50 .46 .42 .47.44 .41 .44 .41 .39 .37
3 .56 .48 .42 .37 .53 .46.41 .36 .43 .39 .35 .41.37 .34 .39 .35 .32 .31
4 .50 .42 .35 .30 .48 .40.34 .30 .38 .33 .29 .36.31 .28 .34 .30 .27 .25
5 .46 .37 .30 .25 .44 .36.29 .25 .34 .28 .24 .32.27 .23 .30 .26 .23 .21
6 .42 .33 .26 .22 .40 .32.26 .21 .30 .25 .21 .28.24 .20 .27 .23 .20 .18
7 .39 .29 .23 .18 .37 .28.22 .18 .27 .21 .18 .25.21 .17 .24 .20 .17 .15
8 .35 .26 .20 .16 .34 .25.19 .15 .24 .19 .15 .23.18 .15 .21 .17 .14 .13
9 .33 .23 .17 .13 .31 .23.17 .13 .21 .16 .13 .20.16 .13 .19 .15 .12 .11
10 .30 .20 .15 .11 .29 .20.14 .11 .19 .14 .10 .18.13 .10 .17 .13 .10 .09
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.6
Front Side
ANGLE CP ANGL CP
0.0 1795. 0.0 1795.
5.0 1573. 5.0 1595.
15.0 1676. 15.0 1484.
25.0 1997. 25.0 1649.
35.0 2244. 35.0 1694.
45.0 2722. 45.0 1980.
55.0 2726. 55.0 1764.
65.0 2660. 65.0 1451.
75.0 2656. 75.0 452.
85.0 2293. 85.0 109.
90.0 2050. 90.0 42.
95.0 1598. 95.0 28.
105.0 243. 100.0 16.
115.0 75. 115.0 14.
125.0 24. 125.0 13.
135.0 10. 135.0 11.
145.0 6. 145.0 8.
155.0 6. 155.0 6.
165.0 5. 165.0 5.
175.0 4. 175.0 4.
180.0 4. 180.0 4.
Test No. HPK09934
METAL HALIDE, METAL HALIDE PULSE-
VM2, VM4
With Type I All
Glass Refractor
50-250 Watt
Mogul Base
CANDLEPOWER – 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH multiply by 0.64
For 250 MH multiply by 1.46
For 150 MHP multiply by 1.00
For 175 MHP multiply by 1.25
For 200 MHP multiply by 1.50
Efficiency 80.1%
ANGLE CP ANGLE CP
0931. 85.0 2901.
5.0 822. 90.0 1775.
15.0 765. 95.0 1272.
25.0 904. 105.0 746.
35.0 1163. 115.0 514.
45.0 1137. 125.0 267.
55.0 2712. 135.0 153
60.0 7019. 145.0 130.
65.0 9087. 155.0 48.
70.0 7767. 165.0 2.
75.0 5367. 175.0 0.
80.0 3839. 180.0 0.
2000
5000
8000
10,000
90˚
80˚
70˚
60˚
50˚
40˚30˚20˚10˚
180˚ 160˚ 150˚ 140˚ 130˚ 120˚
110˚
100˚
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .93 .93 .93 .93 .89 .89.89 .89 .83 .83 .83 .77.77 .77 .71 .71 .71 .68
1 .78 .72 .66 .61 .75 .69.64 .59 .63 .59 .55 .58.54 .51 .53 .50 .48 .45
2 .68 .58 .50 .43 .64 .55.48 .41 .50 .44 .38 .45.40 .36 .41 .37 .33 .30
3 .59 .47 .38 .31 .56 .45.37 .30 .41 .34 .28 .37.31 .26 .33 .28 .24 .21
4 .53 .40 .30 .23 .50 .38.29 .22 .34 .27 .21 .31.24 .19 .27 .22 .18 .15
5 .47 .34 .25 .18 .45 .33.24 .17 .29 .22 .16 .26.20 .15 .23 .18 .14 .11
6 .43 .30 .21 .15 .41 .28.20 .14 .26 .18 .13 .23.17 .12 .21 .15 .11 .08
7 .40 .26 .18 .12 .37 .25.17 .12 .23 .16 .11 .20.14 .10 .18 .13 .09 .07
8 .36 .24 .16 .10 .34 .23.15 .10 .20 .14 .09 .18.12 .08 .17 .11 .07 .05
9 .34 .21 .14 .09 .32 .20.13 .08 .19 .12 .08 .17.11 .07 .15 .10 .06 .04
10 .32 .20 .12 .08 .30 .19.12 .07 .17 .11 .07 .15.10 .06 .14 .09 .05 .04
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.82 90 -270°
Test No. HPK09930
METAL HALIDE, METAL HALIDE PULSE-
VM2, VM4
With Type III All
Glass Refractor
50-250 Watt
Mogul Base
CANDLEPOWER – 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH multiply by 0.64
For 250 MH multiply by 1.46
For 150 MHP multiply by 1.00
For 175 MHP multiply by 1.25
For 200 MHP multiply by 1.50
Efficiency 79.6%
ANGLE CP ANGLE CP
01124. 85.0 3401.
5.0 892. 90.0 2106.
15.0 933. 95.0 1538.
25.0 999. 105.0 950.
35.0 1321. 115.0 775.
45.0 1435. 125.0 388.
55.0 4091. 135.0 234.
60.0 9397. 145.0 191.
65.0 10450. 155.0 52.
70.0 8609. 165.0 2.
75.0 5577. 175.0 0.
80.0 4262. 180.0 0.
2613
5225
8000
7838
10450
12,000
90˚
80˚
70˚
60˚
50˚
40˚30˚20˚10˚
180˚ 160˚ 150˚ 140˚ 130˚ 120˚
110˚
100˚
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .92 .92 .92 .92 .88 .88.88 .88 .82 .82 .82 .76 .76 .76 .70 .70 .70 .67
1 .78 .72 .66 .61 .74 .68.63 .59 .63 .58 .55 .57.54 .51 .52 .50 .47 .44
2 .67 .57 .49 .43 .64 .55.47 .41 .50 .44 .38 .45.40 .35 .41 .36 .33 .30
3 .59 .47 .38 .31 .56 .45.37 .30 .41 .33 .28 .36.31 .26 .33 .28 .24 .21
4 .52 .40 .30 .23 .49 .38.29 .23 .34 .27 .21 .30.24 .19 .27 .22 .17 .15
5 .47 .34 .25 .18 .44 .32.24 .18 .29 .22 .16 .26.20 .15 .23 .18 .13 .11
6 .43 .30 .21 .15 .40 .28.20 .14 .25 .18 .13 .23.17 .12 .20 .15 .11 .08
7 .39 .26 .18 .12 .37 .25.17 .12 .23 .16 .11 .20.14 .10 .18 .13 .09 .07
8 .36 .24 .16 .10 .34 .23.15 .10 .20 .14 .09 .18.12 .08 .16 .11 .07 .05
9 .34 .21 .14 .09 .32 .20.13 .08 .19 .12 .08 .17.11 .07 .15 .10 .06 .04
10 .32 .20 .12 .08 .30 .19.12 .07 .17 .11 .07 .15.10 .06 .14 .09 .05 .04
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - .74 0-180°
Angle Vertical
CP 90° Horizontal
Angle Vertical
CP 75° Horizontal
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA L125
L
Test No. HPK09929
METAL HALIDE, METAL HALIDE PULSE-
VM2, VM4
With Type V All
Glass Refractor
50-250 Watt
Mogul Base
CANDLEPOWER 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH multiply by 0.68
For 250 MH multiply by 1.46
For 150 MHP multiply by 1.00
For 175 MHP multiply by 1.25
For 200 MHP multiply by 1.50
Efficiency 81.2%
ANGLE CP ANGLE CP
0770. 95.0 565.
5.0 690. 100.0 429.
10.0 645. 105.0 325.
15.0 677. 110.0 291.
20.0 797. 115.0 272.
25.0 927. 120.0 234.
30.0 801. 125.0 203.
35.0 715. 130.0 171.
40.0 687. 135.0 150.
45.0 737. 140.0 129.
50.0 1105. 145.0 114.
55.0 1498. 150.0 75.
60.0 3262. 155.0 27.
65.0 3523. 160.0 6.
70.0 2597. 165.0 2.
75.0 1739. 170.0 0.
80.0 1325. 175.0 0.
85.0 1064. 180.0 0.
90.0 765.
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .92 .92 .92 .92 .89 .89.89 .89 .82 .82 .82 .76 .76 .76 .71 .71 .71 .68
1 .79 .73 .67 .62 .75 .70.65 .60 .64 .60 .56 .59.55 .52 .54 .51 .49 .46
2 .69 .59 .51 .45 .65 .56.49 .43 .51 .46 .40 .47.42 .38 .43 .39 .35 .32
3 .60 .49 .40 .33 .57 .46.38 .32 .42 .35 .30 .38.32 .27 .34 .30 .25 .23
4 .53 .40 .31 .24 .50 .38.30 .23 .35 .27 .22 .31.25 .20 .28 .23 .18 .16
5 .47 .34 .25 .18 .45 .32.24 .18 .29 .22 .16 .26.20 .15 .24 .18 .14 .11
6 .43 .30 .21 .15 .41 .29.20 .14 .26 .19 .13 .23.17 .12 .21 .15 .11 .09
7 .40 .27 .18 .13 .37 .26.18 .12 .23 .16 .11 .21.15 .10 .19 .13 .09 .07
8 .37 .24 .16 .11 .35 .23.15 .10 .21 .14 .09 .19.13 .09 .17 .12 .08 .06
9 .34 .22 .14 .09 .32 .21.14 .09 .19 .13 .08 .17.12 .08 .16 .11 .07 .05
10 .32 .20 .13 .08 .30 .19.12 .08 .17 .11 .07 .16.10 .06 .14 .09 .06 .04
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.4
Test No. HPK09922
METAL HALIDE, METAL HALIDE PULSE-
VM2, VM4
With Enclosed Reflector
50-250 Watt
Mogul Base
CANDLEPOWER 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH multiply by 0.68
For 250 MH multiply by 1.46
For 150 MHP multiply by 1.00
For 175 MHP multiply by 1.25
For 200 MHP multiply by 1.50
Efficiency 66.0%
ANGLE CP ANGLE CP
07782. 95.0 0.
5.0 7098. 100.0 0.
10.0 8370. 105.0 0.
15.0 12328. 110.0 0.
20.0 11704. 115.0 0.
25.0 6692. 120.0 0.
30.0 3144. 125.0 0.
35.0 1799. 130.0 0.
40.0 1352. 135.0 0.
45.0 1136. 140.0 0.
50.0 253. 145.0 0.
55.0 86. 150.0 0.
60.0 47. 155.0 0.
65.0 29. 160.0 0.
70.0 19. 165.0 0.
75.0 12. 170.0 0.
80.0 7. 175.0 0.
85.0 4. 180.0 0.
90.0 0.
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .80 .80 .80 .80 .78 .78.78 .78 .75 .75 .75 .71.71 .71 .69 .69 .69 .67
1 .77 .76 .75 .73 .76 .74 .73 .72 .72 .71 .70 .69.69 .68 .67 .66 .66 .65
2 .75 .73 .71 .69 .74 .71.70 .68 .69 .68 .67 .67.66 .65 .66 .65 .64 .63
3 .73 .70 .67 .65 .71 .69.67 .65 .67 .65 .64 .66.64 .63 .64 .63 .62 .61
4 .70 .67 .64 .62 .69 .66.64 .62 .65 .63 .61 .64.62 .61 .62 .61 .60 .59
5 .68 .64 .62 .60 .67 .64.61 .59 .63 .61 .59 .62.60 .58 .61 .59 .58 .57
6 .66 .62 .59 .57 .66 .62.59 .57 .61 .59 .57 .60.58 .57 .59 .58 .56 .56
7 .64 .60 .57 .55 .64 .60.57 .55 .59 .57 .55 .58.56 .55 .58 .56 .54 .54
8 .62 .58 .55 .53 .62 .58.55 .53 .57 .55 .53 .56.54 .53 .56 .54 .52 .52
9 .60 .56 .53 .51 .60 .55.53 .51 .55 .52 .51 .54.52 .51 .54 .52 .50 .50
10 .56 .51 .48 .46 .56 .51.48 .46 .51 .48 .46 .50.48 .46 .50 .48 .46 .45
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.0
Test No. HPK10129
METAL HALIDE, METAL HALIDE PULSE-
VM2, VM4
With Globe & Full Cutoff
50-250 Watt
Mogul Base
CANDLEPOWER – 175 WATT
14000 lumens
For 50 MH watt multiply by 0.29
For 70 MH watt multiply by 0.40
For 100 MH multiply by 0.68
For 250 MH multiply by 1.46
For 150 MHP multiply by 1.00
For 175 MHP multiply by 1.25
For 200 MHP multiply by 1.50
Efficiency 69.1%
ANGLE CP ANGLE CP
03208. 95.0 0.
5.0 3031. 100.0 0.
10.0 2916. 105.0 0.
15.0 2924. 110.0 0.
20.0 2947. 115.0 0.
25.0 2989. 120.0 0.
30.0 2841. 125.0 0.
35.0 2855. 130.0 0.
40.0 2923. 135.0 0.
45.0 3017. 140.0 0.
50.0 2745. 145.0 0.
55.0 1591. 150.0 0.
60.0 1147. 155.0 0.
65.0 889. 160.0 0.
70.0 665. 165.0 0.
75.0 464. 170.0 0.
80.0 278. 175.0 0.
85.0 116. 180.0 0.
90.0 0.
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .81 .81 .81 .81 .79 .79.79 .79 .76 .76 .76 .73.73 .73 .70 .70 .70 .68
1 .75 .72 .70 .67 .73 .71.68 .66 .68 .66 .64 .65.64 .62 .63 .61 .60 .59
2 .69 .64 .60 .57 .68 .63.59 .56 .61 .58 .55 .59.56 .54 .57 .55 .53 .51
3 .64 .58 .53 .49 .63 .57.52 .49 .55 .51 .48 .53.50 .47 .51 .49 .46 .45
4 .59 .52 .46 .42 .57 .51.46 .42 .49 .45 .41 .48.44 .41 .46 .43 .40 .39
5 .54 .46 .41 .36 .53 .46.40 .36 .44 .39 .36 .43.39 .36 .42 .38 .35 .34
6 .50 .42 .36 .32 .49 .41.36 .32 .40 .35 .32 .39.35 .31 .38 .34 .31 .30
7 .46 .37 .32 .28 .45 .37.32 .28 .36 .31 .27 .35.31 .27 .34 .30 .27 .26
8 .43 .34 .28 .24 .42 .33.28 .24 .32 .27 .24 .31.27 .24 .31 .27 .24 .22
9 .39 .30 .25 .21 .38 .30.25 .21 .29 .24 .21 .28.24 .21 .28 .24 .21 .19
10 .35 .26 .21 .17 .35 .26.21 .17 .25 .20 .17 .25.20 .17 .24 .20 .17 .16
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.4
*Values using Dark Sky gasket kit
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA
L126
Test No. HPK09924
HIGH PRESSURE SODIUM-VM5
With Globe
200-400 Watt
Mogul Base
CANDLEPOWER – 400 WATT
51000 lumens
For 200 watt multiply by 0.43
For 250 watt multiply by 0.53
Efficiency 89.6%
ANGLE CP ANGLE CP
0563. 95.0 5076.
5.0 518. 100.0 4976.
10.0 801. 105.0 4846.
15.0 1271. 110.0 4658.
20.0 1697. 115.0 4383.
25.0 1751. 120.0 4013.
30.0 2066. 125.0 3556.
35.0 2723. 130.0 3050.
40.0 3176. 135.0 2237.
45.0 3744. 140.0 1388.
50.0 4122. 145.0 653.
55.0 4341. 150.0 113.
60.0 4639. 155.0 32.
65.0 4708. 160.0 19.
70.0 4877. 165.0 9.
75.0 5015. 170.0 0.
80.0 5086. 175.0 0.
85.0 5124. 180.0 0.
90.0 5136.
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .97 .97 .97 .97 .90 .90.90 .90 .77 .77 .77 .66.66 .66 .55 .55 .55 .50
1 .83 .77 .71 .66 .76 .71.66 .61 .59 .56 .52 .49.46 .43 .40 .37 .35 .30
2 .73 .64 .56 .50 .67 .59.52 .46 .49 .44 .39 .40.36 .32 .32 .28 .26 .21
3 .66 .55 .46 .39 .60 .50.42 .36 .42 .35 .30 .34.29 .25 .26 .23 .19 .16
4 .59 .47 .38 .31 .54 .43.35 .29 .36 .29 .24 .29.24 .19 .22 .18 .15 .12
5 .54 .41 .32 .25 .49 .37.29 .23 .31 .24 .19 .25.20 .16 .19 .15 .12 .09
6 .49 .36 .27 .21 .45 .33.25 .19 .27 .21 .16 .22.17 .13 .17 .13 .10 .07
7 .45 .32 .23 .18 .41 .29.22 .16 .24 .18 .13 .19.14 .10 .15 .11 .08 .05
8 .41 .28 .20 .15 .37 .26.19 .13 .21 .15 .11 .17.12 .09 .13 .09 .06 .04
9 .38 .25 .18 .13 .35 .23.16 .12 .19 .13 .09 .16.11 .07 .12 .08 .05 .03
10 .35 .23 .15 .11 .32 .21.14 .10 .17 .12 .08 .14 .09 .06 .11 .07 .04 .02
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 4.3
Test No. HPK09928
HIGH PRESSURE SODIUM-VM5
With Globe & Angle Reflector
200-400 Watt
Mogul Base
CANDLEPOWER 400 WATT
51000 lumens
For 200 watt multiply by 0.43
For 250 watt multiply by 0.53
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .83 .83 .83 .83 .80 .80.80 .80 .74 .74 .74 .69.69 .69 .64 .64 .64 .61
1 .72 .67 .63 .59 .69 .64.60 .57 .59 .56 .53 .55.52 .50 .50 .48 .46 .44
2 .64 .57 .50 .45 .61 .54.49 .44 .50 .45 .41 .46.42 .39 .42 .39 .36 .34
3 .58 .49 .42 .36 .55 .47.40 .35 .43 .38 .33 .40.35 .31 .36 .33 .29 .27
4 .52 .42 .35 .29 .49 .40.34 .28 .37 .31 .27 .34.29 .25 .31 .27 .24 .22
5 .47 .37 .29 .24 .45 .35.28 .23 .32 .27 .22 .30.25 .21 .27 .23 .20 .18
6 .43 .32 .25 .20 .41 .31.24 .20 .29 .23 .19 .26.21 .18 .24 .20 .17 .15
7 .39 .29 .22 .17 .37 .27.21 .16 .25 .20 .15 .23.18 .15 .22 .17 .14 .12
8 .36 .25 .19 .14 .34 .24.18 .14 .23 .17 .13 .21.16 .12 .19 .15 .12 .10
9 .33 .23 .16 .12 .32 .22.16 .12 .20 .15 .11 .19.14 .11 .17 .13 .10 .08
10 .30 .20 .14 .10 .29 .19 .13 .09 .18 .13 .09 .17 .12 .08 .15 .11 .08 .06
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 2.2
Front Side
ANGLE CP ANGL CP
0.0 3671.0.0 3671.
5.0 3848.5.0 3650.
15.0 4977.15.0 4318.
25.0 5665.25.0 4556.
35.0 6622.35.0 5230.
45.0 7632.45.0 5923.
55.0 8016.55.0 6362.
65.0 8138.65.0 6188.
75.0 7962.75.0 5540.
85.0 7360.85.0 2953.
90.0 6987.90.0 1639.
95.0 6468.95.0 566.
105.0 4805.100.0 97.
115.0 2021.115.0 80.
125.0 166.125.0 62.
135.0 60.135.0 48.
140.0 42.140.0 41.
145.0 30.145.0 45.
155.0 20.155.0 28.
165.0 15.165.0 18.
175.0 12.175.0 12.
180.0 0.180.0 0.
Test No. HPK09927
HIGH PRESSURE SODIUM-VM5
With Globe & Reflector
200-400 Watt
Mogul Base
CANDLEPOWER – 400 WATT
51000 lumens
For 200 watt multiply by 0.43
For 250 watt multiply by 0.53
Efficiency 75.3%
ANGLE CP ANGLE CP
03828. 95.0 1835.
5.0 3788. 100.0 692.
10.0 4046. 105.0 137.
15.0 4430. 110.0 135.
20.0 4752. 115.0 120.
25.0 4674. 120.0 246.
30.0 4837. 125.0 314.
35.0 5337. 130.0 302.
40.0 5676. 135.0 271.
45.0 6115. 140.0 93.
50.0 6352. 145.0 38.
55.0 6439. 150.0 37.
60.0 6562. 155.0 31.
65.0 6474. 160.0 25.
70.0 6419. 165.0 23.
75.0 6211. 170.0 20.
80.0 5784. 175.0 17.
85.0 4480. 180.0 0.
90.0 3031.
% EFFECTIVE
CEILINGCAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .88 .88 .88 .88 .85 .85.85 .85 .80 .80 .80 .76 .76 .76 .72 .72 .72 .70
1 .76 .70 .65 .60 .73 .68.63 .59 .63 .59 .56 .59.56 .53 .55 .53 .50 .48
2 .67 .58 .51 .45 .64 .56.50 .44 .52 .47 .42 .49.44 .40 .46 .42 .38 .36
3 .60 .49 .42 .35 .57 .48.40 .34 .44 .38 .33 .41.36 .32 .39 .34 .30 .28
4 .54 .42 .34 .28 .51 .41.33 .27 .38 .32 .26 .36.30 .25 .33 .28 .24 .22
5 .49 .37 .29 .23 .46 .36.28 .22 .33 .27 .21 .31.25 .21 .29 .24 .20 .18
6 .44 .33 .25 .19 .42 .31.24 .19 .29 .23 .18 .28.22 .17 .26 .21 .17 .15
7 .41 .29 .21 .16 .39 .28.21 .16 .26 .20 .15 .24.19 .14 .23 .18 .14 .12
8 .37 .26 .18 .13 .36 .25.18 .13 .23 .17 .13 .22.16 .12 .20 .15 .12 .10
9 .35 .23 .16 .11 .33 .22.16 .11 .21 .15 .11 .20.14 .10 .19 .14 .10 .08
10 .32 .20 .14 .09 .30 .20.13 .09 .19 .13 .09 .17.12 .08 .16 .12 .08 .07
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 2.2
Efficiency 71.6%
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA L127
L
Test No. HPK09932
HIGH PRESSURE SODIUM-VM5
With Type II 12" Spintop Refractor
200-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
51000 lumens
For 200 watt multiply by 0.43
For 250 watt multiply by 0.53
Efficiency 78.7%
ANGLE CP ANGLE CP
05783. 85.0 8444.
5.0 5146. 90.0 5658.
15.0 4341. 95.0 4295.
25.0 4133. 105.0 2609.
35.0 4569. 115.0 1903.
45.0 7301. 125.0 2030.
55.0 10633. 135.0 1964.
60.0 11449. 145.0 1415.
65.0 11950. 155.0 764.
70.0 11914. 165.0 200.
75.0 11449. 175.0 0.
80.0 10538. 180.0 0.
2000
5000
10000
14000
90˚
80˚
70˚
60˚
50˚
40˚30˚20˚10˚
180˚ 160˚ 150˚ 140˚ 130˚ 120˚
110˚
100˚
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .89 .89 .89 .89 .85 .85.85 .85 .78 .78 .78 .71.71 .71 .64 .64 .64 .61
1 .77 .72 .67 .63 .73 .68.64 .60 .62 .58 .55 .55.53 .50 .50 .48 .45 .42
2 .68 .60 .53 .47 .64 .56.50 .45 .51 .45 .41 .45.41 .37 .40 .37 .34 .31
3 .61 .50 .42 .36 .57 .48.40 .34 .43 .37 .32 .38.33 .29 .34 .30 .26 .23
4 .54 .43 .35 .28 .51 .41.33 .27 .36 .30 .25 .32.27 .23 .29 .24 .21 .18
5 .49 .37 .29 .23 .46 .35.28 .22 .32 .25 .20 .28.23 .18 .25 .20 .17 .14
6 .45 .33 .25 .19 .42 .31.24 .18 .28 .21 .17 .25.19 .15 .22 .17 .14 .11
7 .41 .29 .21 .16 .39 .28.20 .15 .25 .19 .14 .22.17 .13 .20 .15 .11 .09
8 .38 .26 .19 .14 .36 .25.18 .13 .22 .16 .12 .20.15 .11 .18 .13 .10 .08
9 .35 .24 .17 .12 .33 .23.16 .11 .20 .14 .10 .18.13 .09 .16 .12 .08 .07
10 .33 .22 .15 .10 .31 .21.14 .10 .19 .13 .09 .17.12 .08 .15 .10 .07 .06
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.38 0-180°
Test No. HPK09931
HIGH PRESSURE SODIUM-VM5
With Type V 12" Spintop Reflector
200-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
51000 lumens
For 200 watt multiply by 0.43
For 250 watt multiply by 0.53
Efficiency 83.6%
ANGLE CP ANGLE CP
06501. 95.0 2033.
5.0 6106. 100.0 1561.
10.0 5125. 105.0 1178.
15.0 4402. 110.0 1065.
20.0 4098. 115.0 1121.
25.0 3941. 120.0 1099.
30.0 4003. 125.0 955.
35.0 4315. 130.0 818.
40.0 4900. 135.0 688.
45.0 5411. 140.0 566.
50.0 5865. 145.0 433.
55.0 6247. 150.0 326.
60.0 6844. 155.0 237.
65.0 7429. 160.0 118.
70.0 7453. 165.0 32.
75.0 7142. 170.0 0.
80.0 6432. 175.0 0.
85.0 4703. 180.0 0.
90.0 2943.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .96 .96 .96 .96 .93 .93.93 .93 .86 .86 .86 .80.80 .80 .74 .74 .74 .71
1 .83 .77 .71 .67 .79 .74 .69 .64 .68 .64 .60 .62.59 .56 .57 .54 .52 .49
2 .73 .63 .55 .49 .69 .60.53 .47 .55 .49 .44 .50.45 .41 .46 .42 .38 .35
3 .64 .53 .44 .37 .61 .51.42 .36 .46 .39 .34 .42.36 .31 .38 .33 .29 .26
4 .58 .46 .37 .30 .55 .44.35 .29 .40 .33 .27 .36.30 .25 .33 .28 .24 .21
5 .53 .40 .31 .24 .50 .38.30 .23 .35 .27 .22 .32.25 .20 .29 .23 .19 .17
6 .48 .35 .26 .20 .45 .33.25 .19 .30 .23 .18 .28.22 .17 .25 .20 .16 .13
7 .44 .31 .22 .16 .41 .29.22 .16 .27 .20 .15 .25.18 .14 .22 .17 .13 .11
8 .41 .28 .20 .14 .38 .27.19 .14 .24 .18 .13 .22.16 .12 .20 .15 .11 .09
9 .38 .25 .17 .12 .36 .24.17 .12 .22 .16 .11 .20.14 .10 .18 .13 .10 .08
10 .35 .23 .15 .11 .33 .22.15 .10 .20 .14 .10 .18.13 .09 .17 .12 .08 .07
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - .8
Test No. HPK09933
HIGH PRESSURE SODIUM-VM5
With Enclosed Reflector
200-600 Watt
Mogul Base
CANDLEPOWER –
400 WATT
51000 lumens
For 200 watt multiply by 0.43
For 250 watt multiply by 0.53
For 600 watt multiply by 1.76
Efficiency 71.1%
ANGLE CP ANGLE CP
06143. 95.0 0.
5.0 5212. 100.0 0.
10.0 5113. 105.0 0.
15.0 5867. 110.0 0.
20.0 8229. 115.0 0.
25.0 13084. 120.0 0.
30.0 16492. 125.0 0.
35.0 17256. 130.0 0.
40.0 16279. 135.0 0.
45.0 13771. 140.0 0.
50.0 10012. 145.0 0.
55.0 5931. 150.0 0.
60.0 2913. 155.0 0.
65.0 1160. 160.0 0.
70.0 263. 165.0 0.
75.0 128. 170.0 0.
80.0 60. 175.0 0.
85.0 27. 180.0 0.
90.0 0.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .85 .85 .85 .85 .83 .83.83 .83 .79 .79 .79 .76 .76 .76 .73 .73 .73 .71
1 .79 .77 .75 .72 .78 .75.73 .71 .72 .71 .69 .70.68 .67 .67 .66 .65 .64
2 .74 .70 .66 .63 .73 .68.65 .62 .66 .63 .61 .64.62 .59 .62 .60 .58 .57
3 .69 .63 .59 .55 .68 .62.58 .54 .60 .57 .54 .58.55 .53 .57 .54 .52 .51
4 .64 .56 .51 .47 .62 .56.51 .47 .54 .50 .46 .52.49 .46 .51 .48 .45 .44
5 .58 .51 .45 .41 .57 .50.45 .41 .48 .44 .40 .47.43 .40 .46 .42 .39 .38
6 .54 .45 .39 .35 .52 .44.39 .35 .43 .38 .35 .42.38 .34 .41 .37 .34 .33
7 .49 .40 .34 .30 .48 .39.34 .30 .38 .33 .29 .37.33 .29 .36 .32 .29 .28
8 .44 .35 .29 .25 .43 .34.29 .25 .34 .28 .25 .33.28 .25 .32 .28 .24 .23
9 .40 .31 .25 .21 .39 .30.25 .21 .29 .24 .21 .29.24 .20 .28 .24 .20 .19
10 .35 .25 .19 .15 .34 .25.19 .15 .24 .19 .15 .23.19 .15 .23 .18 .15 .14
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 2.3
Angle Vertical, CP 75° Horizontal
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA
L128
Test No. HPK09925
HIGH PRESSURE SODIUM-VM5
With Globe & Deep White Reflector
200-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
51000 lumens
For 200 watt multiply by 0.43
For 250 watt multiply by 0.53
Efficiency 70.4%
ANGLE CP ANGLE CP
08039. 95.0 29.
5.0 7957. 100.0 36.
10.0 8160. 105.0 43.
15.0 8458. 110.0 49.
20.0 8642. 115.0 54.
25.0 8404. 120.0 59.
30.0 8416. 125.0 63.
35.0 8850. 130.0 64.
40.0 9018. 135.0 55.
45.0 9370. 140.0 43.
50.0 9428. 145.0 108.
55.0 9050. 150.0 88.
60.0 7641. 155.0 26.
65.0 5305. 160.0 15.
70.0 3143. 165.0 11.
75.0 1895. 170.0 0.
80.0 1073. 175.0 0.
85.0 448. 180.0 0.
90.0 30.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .84 .84 .84 .84 .82 .82.82 .82 .78 .78 .78 .75.75 .75 .72 .72 .72 .70
1 .77 .74 .71 .68 .75 .72.69 .67 .69 .67 .65 .66.64 .62 .63 .62 .60 .59
2 .70 .65 .60 .56 .68 .63.59 .55 .61 .57 .54 .58.55 .53 .56 .54 .51 .50
3 .64 .57 .51 .47 .62 .56.51 .46 .54 .49 .45 .52.48 .45 .50 .46 .44 .42
4 .58 .50 .43 .39 .57 .49.43 .38 .47 .42 .38 .45.41 .37 .44 .40 .37 .35
5 .53 .44 .37 .32 .51 .43.37 .32 .41 .36 .32 .40.35 .31 .38 .34 .31 .29
6 .48 .39 .32 .28 .47 .38.32 .28 .37 .31 .27 .35.31 .27 .34 .30 .27 .25
7 .44 .34 .28 .23 .43 .34.28 .23 .33 .27 .23 .31.26 .23 .30 .26 .23 .21
8 .41 .30 .24 .20 .39 .30.24 .20 .29 .23 .20 .28.23 .19 .27 .23 .19 .18
9 .37 .27 .21 .17 .36 .27.21 .17 .26 .21 .17 .25.20 .17 .24 .20 .17 .15
10 .34 .24 .18 .14 .33 .23.18 .14 .23 .17 .14 .22.17 .14 .21 .17 .13 .12
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.7
Test No. HPK09926
HIGH PRESSURE SODIUM-VM5
With Globe & Deep Alzak Reflector
200-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
51000 lumens
For 200 watt multiply by 0.43
For 250 watt multiply by 0.53
Efficiency 69.2%
ANGLE CP ANGLE CP
05167. 95.0 14.
5.0 5283. 100.0 14.
10.0 6074. 105.0 14.
15.0 6962. 110.0 15.
20.0 7637. 115.0 14.
25.0 7876. 120.0 14.
30.0 8220. 125.0 13.
35.0 9004. 130.0 12.
40.0 9663. 135.0 11.
45.0 10471. 140.0 13.
50.0 10790. 145.0 86.
55.0 10201. 150.0 74.
60.0 8174. 155.0 19.
65.0 5041. 160.0 15.
70.0 2326. 165.0 10.
75.0 1015. 170.0 0.
80.0 426. 175.0 0.
85.0 153. 180.0 0.
90.0 21.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .83 .83 .83 .83 .81 .81.81 .81 .77 .77 .77 .74 .74 .74 .71 .71 .71 .69
1 .76 .73 .70 .68 .74 .71.69 .67 .68 .66 .64 .66.64 .62 .63 .62 .60 .59
2 .70 .64 .60 .56 .68 .63.59 .55 .60 .57 .54 .58.55 .53 .56 .54 .52 .50
3 .64 .57 .51 .47 .62 .55.50 .46 .53 .49 .46 .51.48 .45 .50 .47 .44 .42
4 .57 .49 .43 .38 .56 .48.43 .38 .46 .42 .38 .45.41 .37 .43 .40 .37 .35
5 .52 .43 .37 .32 .51 .42.36 .32 .41 .35 .31 .39.35 .31 .38 .34 .31 .29
6 .47 .38 .31 .27 .46 .37.31 .27 .36 .30 .26 .35.30 .26 .33 .29 .26 .24
7 .43 .33 .27 .22 .42 .32.26 .22 .31 .26 .22 .30.25 .22 .29 .25 .21 .20
8 .39 .29 .23 .18 .38 .28.22 .18 .27 .22 .18 .27.22 .18 .26 .21 .18 .16
9 .36 .26 .20 .16 .35 .25.19 .15 .25 .19 .15 .24.19 .15 .23 .18 .15 .14
10 .32 .22 .16 .12 .31 .22.16 .12 .21 .16 .12 .20.15 .12 .20 .15 .12 .10
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 2.5
Test No. HPK09911
METAL HALIDE, METAL HALIDE PULSE-
VM5
With Globe
250-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
36000 lumens
For 250 MH multiply by 0.61
For 250 MHP multiply by 0.66
For 320 MHP multiply by 0.92
For 350 MHP multiply by 1.00
For 400 MHP multiply by 1.22
Efficiency 92.4%
ANGLE CP ANGLE CP
0529. 95.0 3527.
5.0 538. 100.0 3475.
10.0 690. 105.0 3403.
15.0 896. 110.0 3325.
20.0 1223. 115.0 3203.
25.0 1288. 120.0 3026.
30.0 1074. 125.0 2854.
35.0 2101. 130.0 2667.
40.0 2807. 135.0 2379.
45.0 2718. 140.0 1779.
50.0 2770. 145.0 508.
55.0 2942. 150.0 55.
60.0 3133. 155.0 26.
65.0 3353. 160.0 15.
70.0 3493. 165.0 8.
75.0 3530. 170.0 0.
80.0 3489. 175.0 0.
85.0 3497. 180.0 0.
90.0 3523.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .100 .100.100 .100.92 .92.92 .92 .79 .79 .79 .66.66 .66 .55 .55 .55 .50
1 .86 .79 .73 .68 .78 .73.68 .63 .61 .57 .53 .50.47 .44 .40 .38 .36 .31
2 .76 .66 .58 .52 .69 .61.54 .48 .50 .45 .40 .41.37 .33 .32 .29 .26 .22
3 .68 .57 .48 .41 .62 .52.44 .38 .43 .37 .31 .35.30 .26 .27 .23 .20 .16
4 .61 .49 .40 .33 .56 .45.36 .30 .37 .30 .25 .29.24 .20 .23 .19 .15 .12
5 .55 .42 .33 .27 .50 .39.31 .24 .32 .25 .20 .26.20 .16 .20 .16 .12 .09
6 .51 .37 .28 .22 .46 .34.26 .20 .28 .22 .17 .23.17 .13 .17 .13 .10 .07
7 .46 .33 .25 .18 .42 .30.22 .17 .25 .19 .14 .20.15 .11 .15 .11 .08 .05
8 .43 .29 .21 .16 .39 .27.19 .14 .22 .16 .12 .18.13 .09 .14 .10 .07 .04
9 .39 .26 .19 .13 .36 .24.17 .12 .20 .14 .10 .16.11 .08 .12 .08 .05 .03
10 .36 .24 .16 .11 .33 .22.15 .10 .18 .12 .08 .14 .10 .06 .11 .07 .04 .02
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 3.6
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA L129
L
Test No. HPK09912
METAL HALIDE, METAL HALIDE PULSE -
VM5
With Globe & Guard
250-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
36000 lumens
For 250 MH multiply by 0.61
For 250 MHP multiply by 0.66
For 320 MHP multiply by 0.92
For 350 MHP multiply by 1.00
For 400 MHP multiply by 1.22
Efficiency 88.7%
ANGLE CP ANGLE CP
0844. 95.0 3523.
5.0 804. 100.0 3454.
10.0 877. 105.0 3290.
15.0 998. 110.0 3030.
20.0 1266. 115.0 2863.
25.0 1240. 120.0 2764.
30.0 1071. 125.0 2832.
35.0 1830. 130.0 2643.
40.0 2625. 135.0 2324.
45.0 2730. 140.0 1482.
50.0 2787. 145.0 191.
55.0 2934. 150.0 107.
60.0 2932. 155.0 106.
65.0 3052. 160.0 109.
70.0 3155. 165.0 110.
75.0 3309. 170.0 0.
80.0 3433. 175.0 0.
85.0 3465. 180.0 0.
90.0 3496.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .96 .96 .96 .96 .89 .89.89 .89 .76 .76 .76 .64.64 .64 .53 .53 .53 .48
1 .82 .76 .70 .65 .75 .70.65 .61 .58 .55 .51 .48.45 .42 .38 .36 .34 .29
2 .73 .64 .56 .50 .66 .58.52 .46 .48 .43 .39 .39.35 .32 .31 .28 .25 .21
3 .65 .54 .46 .39 .59 .50.42 .36 .41 .35 .30 .33.29 .25 .26 .22 .19 .15
4 .59 .47 .38 .31 .53 .43.35 .29 .35 .29 .24 .28.23 .19 .22 .18 .15 .12
5 .53 .41 .32 .26 .48 .37.29 .24 .31 .24 .20 .25.20 .16 .19 .15 .12 .09
6 .49 .36 .27 .21 .44 .33.25 .20 .27 .21 .16 .22.17 .13 .17 .13 .10 .07
7 .45 .32 .24 .18 .40 .29.22 .16 .24 .18 .14 .19 .14 .11 .15 .11 .08 .05
8 .41 .28 .20 .15 .37 .26.19 .14 .21 .16 .11 .17.12 .09 .13 .09 .06 .04
9 .38 .26 .18 .13 .34 .23.17 .12 .19 .14 .10 .15 .11 .07 .12 .08 .05 .03
10 .35 .23 .16 .11 .32 .21.14 .10 .17 .12 .08 .14 .09 .06 .11 .07 .04 .02
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 3.2
Test No. HPK09918
METAL HALIDE, METAL HALIDE PULSE -
VM5
With Globe &
Dome Reflector
250-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
36000 lumens
For 250 MH multiply by 0.61
For 250 MHP multiply by 0.66
For 320 MHP multiply by 0.92
For 350 MHP multiply by 1.00
For 400 MHP multiply by 1.22
Efficiency 76.1%
ANGLE CP ANGLE CP
03088. 95.0 551.
5.0 3105. 100.0 125.
10.0 3239. 105.0 106.
15.0 3370. 110.0 95.
20.0 3603. 115.0 83.
25.0 3544. 120.0 70.
30.0 3218. 125.0 171.
35.0 4119. 130.0 441.
40.0 4720. 135.0 257.
45.0 4510. 140.0 35.
50.0 4417. 145.0 36.
55.0 4478. 150.0 25.
60.0 4526. 155.0 21.
65.0 4629. 160.0 18.
70.0 4602. 165.0 15.
75.0 4381. 170.0 14.
80.0 4047. 175.0 12.
85.0 3613. 180.0 11.
90.0 2234.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .90 .90 .90 .90 .87 .87.87 .87 .83 .83 .83 .78.78 .78 .74 .74 .74 .73
1 .76 .71 .65 .61 .74 .68.64 .59 .64 .60 .57 .61.57 .54 .57 .54 .52 .50
2 .68 .59 .51 .45 .65 .57.50 .44 .53 .48 .43 .50.45 .41 .47 .43 .40 .38
3 .61 .50 .42 .36 .58 .48.41 .35 .46 .39 .34 .43.37 .33 .40 .36 .32 .29
4 .54 .43 .35 .28 .52 .42.34 .28 .39 .32 .27 .37.31 .26 .35 .30 .25 .23
5 .49 .37 .29 .23 .47 .36.29 .23 .34 .27 .22 .32.26 .21 .30 .25 .21 .19
6 .45 .33 .25 .19 .43 .32.25 .19 .30 .24 .19 .29.23 .18 .27 .22 .18 .16
7 .41 .29 .22 .16 .40 .29.21 .16 .27 .20 .16 .25.20 .15 .24 .19 .15 .13
8 .38 .26 .19 .14 .36 .25.18 .13 .24 .18 .13 .23.17 .13 .22 .16 .12 .11
9 .35 .24 .16 .12 .34 .23.16 .12 .22 .16 .11 .21.15 .11 .20 .14 .11 .09
10 .32 .21 .14 .09 .31 .20.14 .09 .19 .13 .09 .18.13 .09 .17 .12 .09 .07
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 2.0
Test No. HPK09917
METAL HALIDE, METAL HALIDE PULSE -
VM5
With Globe & Angle Reflector
250-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
36000 lumens
For 250 MH multiply by 0.61
For 250 MHP multiply by 0.66
For 320 MHP multiply by 0.92
For 350 MHP multiply by 1.00
For 400 MHP multiply by 1.22
Efficiency 73.3%
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .85 .85 .85 .85 .82 .82.82 .82 .76 .76 .76 .70.70 .70 .65 .65 .65 .63
1 .74 .69 .65 .61 .71 .66.62 .59 .61 .58 .55 .56.54 .51 .52 .50 .48 .46
2 .66 .59 .52 .47 .63 .56.50 .46 .52 .47 .43 .48.44 .40 .44 .41 .38 .36
3 .60 .50 .43 .38 .57 .48.42 .37 .45 .39 .35 .41.37 .33 .38 .34 .31 .29
4 .54 .44 .36 .30 .51 .42.35 .30 .39 .33 .28 .36.31 .27 .33 .29 .25 .23
5 .49 .38 .31 .25 .46 .37.30 .24 .34 .28 .23 .31.26 .22 .29 .24 .21 .19
6 .45 .34 .26 .21 .42 .32.26 .21 .30 .24 .20 .28.22 .19 .26 .21 .18 .16
7 .41 .30 .23 .18 .39 .29.22 .17 .27 .21 .16 .25.19 .16 .23 .18 .15 .13
8 .37 .26 .20 .15 .36 .25.19 .15 .24 .18 .14 .22.17 .13 .20 .16 .12 .11
9 .35 .24 .17 .13 .33 .23.17 .12 .21 .16 .12 .20.15 .11 .18 .14 .11 .09
10 .32 .21 .15 .10 .30 .20.14 .10 .19 .13 .10 .17.12 .09 .16 .12 .08 .07
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 2.2
Front Side
ANGLE CP ANGL CP
0.0 2962. 0.0 2962.
5.0 3212. 5.0 2991.
15.0 3923. 15.0 3278.
25.0 4545. 25.0 3440.
35.0 5416. 35.0 3975.
45.0 5946. 45.0 4381.
55.0 6169. 55.0 4289.
65.0 6365. 65.0 4443.
75.0 6074. 75.0 4137.
85.0 5553. 85.0 1868.
90.0 5239. 90.0 502.
95.0 4849. 95.0 145.
105.0 3991. 100.0 76.
115.0 1680. 115.0 57.
125.0 83. 125.0 46.
135.0 41. 135.0 35.
145.0 33. 145.0 31.
155.0 13. 155.0 19.
165.0 10. 165.0 13.
175.0 8. 175.0 8.
180.0 6. 180.0 6.
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA
L130
Test No. HPK10081
METAL HALIDE, METAL HALIDE PULSE-
VM5
With Type II 12" Spintop Refractor
250-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
36000 lumens
For 250 MH multiply by 0.61
For 250 MHP multiply by 0.66
For 320 MHP multiply by 0.92
For 350 MHP multiply by 1.00
For 400 MHP multiply by 1.22
Efficiency 78.8%
ANGLE CP ANGLE CP
03548. 85.0 3897.
5.0 3303. 90.0 3203.
15.0 2932. 95.0 2829.
25.0 2791. 105.0 1774.
35.0 3115. 115.0 1293.
45.0 5458. 125.0 1303.
55.0 8761. 135.0 1335.
60.0 10352. 145.0 1046.
65.0 10896. 155.0 621.
70.0 10085. 165.0 178.
75.0 8039. 175.0 0.
80.0 5379. 180.0 0.
2724
5448
8172
10896
90˚
80˚
70˚
60˚
50˚
40˚30˚20˚10˚
180˚ 160˚ 150˚ 140˚ 130˚ 120˚
110˚
100˚
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .89 .89 .89 .89 .85 .85.85 .85 .77 .77 .77 .70.70 .70 .64 .64 .64 .61
1 .78 .73 .68 .64 .74 .69.65 .61 .62 .59 .56 .56.53 .51 .50 .48 .46 .43
2 .69 .60 .53 .48 .65 .57.51 .46 .51 .46 .42 .46.42 .38 .41 .38 .35 .32
3 .61 .51 .43 .37 .57 .48.41 .35 .43 .37 .32 .38.33 .29 .34 .30 .27 .24
4 .55 .44 .35 .29 .51 .41.34 .28 .37 .30 .25 .33.27 .23 .29 .25 .21 .18
5 .50 .38 .30 .23 .46 .36.28 .22 .32 .25 .21 .28.23 .19 .25 .20 .17 .14
6 .45 .33 .25 .19 .42 .31.24 .19 .28 .22 .17 .25.19 .15 .22 .17 .14 .12
7 .41 .29 .22 .16 .39 .28.21 .16 .25 .19 .14 .22.17 .13 .20 .15 .11 .09
8 .38 .26 .19 .14 .36 .25.18 .13 .22 .16 .12 .20.15 .11 .18 .13 .10 .08
9 .35 .24 .17 .12 .33 .23.16 .11 .20 .14 .10 .18.13 .09 .16 .12 .08 .07
10 .33 .22 .15 .10 .31 .20.14 .10 .18 .13 .09 .16.12 .08 .15 .10 .07 .06
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.88 0-180°
Test No. HPK10078
METAL HALIDE, METAL HALIDE PULSE-
VM5
With Type V 12" Spintop Refractor
250-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
36000 lumens
For 250 MH multiply by 0.61
For 250 MHP multiply by 0.66
For 320 MHP multiply by 0.92
For 350 MHP multiply by 1.00
For 400 MHP multiply by 1.22
Efficiency 82.3%
ANGLE CP ANGLE CP
04106. 95.0 1359.
5.0 3914. 100.0 1093.
10.0 3394. 105.0 856.
15.0 3010. 110.0 786.
20.0 2887. 115.0 823.
25.0 2709. 120.0 748.
30.0 2679. 125.0 621.
35.0 2886. 130.0 559.
40.0 3317. 135.0 511.
45.0 3681. 140.0 424.
50.0 3856. 145.0 316.
55.0 4557. 150.0 226.
60.0 5736. 155.0 161.
65.0 6936. 160.0 85.
70.0 6547. 165.0 26.
75.0 4564. 170.0 0.
80.0 3005. 175.0 0.
85.0 2015. 180.0 0.
90.0 1593.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .95 .95 .95 .95 .91 .91.91 .91 .84 .84 .84 .78.78 .78 .73 .73 .73 .70
1 .82 .77 .72 .67 .79 .74 .69 .65 .68 .64 .61 .62.59 .56 .57 .55 .53 .50
2 .73 .64 .56 .50 .69 .61.54 .48 .56 .50 .45 .51.46 .42 .47 .43 .40 .37
3 .64 .53 .45 .38 .61 .51.43 .37 .47 .40 .35 .43.37 .33 .39 .34 .30 .28
4 .57 .45 .36 .30 .54 .43.35 .29 .39 .32 .27 .36.30 .25 .33 .28 .23 .21
5 .52 .39 .30 .23 .49 .37.29 .23 .34 .27 .21 .31.25 .20 .28 .23 .18 .16
6 .47 .34 .26 .20 .45 .33.25 .19 .30 .23 .18 .27.21 .17 .25 .20 .15 .13
7 .43 .30 .22 .16 .41 .29.21 .16 .27 .20 .15 .24.18 .14 .22 .17 .13 .11
8 .40 .27 .19 .14 .38 .26.19 .13 .24 .17 .13 .22.16 .12 .20 .15 .11 .09
9 .37 .25 .17 .12 .35 .24.17 .12 .22 .15 .11 .20.14 .10 .18 .13 .09 .08
10 .34 .22 .15 .10 .32 .21.14 .10 .19 .13 .09 .18 .12 .08 .16 .11 .08 .06
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - .9
Angle Vertical
CP 75° Horizontal
Test No. HPK10077
METAL HALIDE, METAL HALIDE PULSE-
VM5
With Enclosed Reflector
250-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
36000 lumens
For 250 MH multiply by 0.61
For 250 MHP multiply by 0.66
For 320 MHP multiply by 0.92
For 350 MHP multiply by 1.00
For 400 MHP multiply by 1.22
Efficiency 71.5%
ANGLE CP ANGLE CP
05576. 95.0 0.
5.0 5010. 100.0 0.
10.0 4513. 105.0 0.
15.0 4291. 110.0 0.
20.0 4758. 115.0 0.
25.0 6978. 120.0 0.
30.0 11554. 125.0 0.
35.0 15300. 130.0 0.
40.0 14033. 135.0 0.
45.0 9613. 140.0 0.
50.0 5974. 145.0 0.
55.0 3716. 150.0 0.
60.0 1324. 155.0 0.
65.0 521. 160.0 0.
70.0 295. 165.0 0.
75.0 143. 170.0 0.
80.0 60. 175.0 0.
85.0 21. 180.0 0.
90.0 0.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .86 .86 .86 .86 .84 .84.84 .84 .80 .80 .80 .77.77 .77 .74 .74 .74 .72
1 .81 .78 .76 .73 .79 .76.74 .72 .73 .72 .70 .71.69 .68 .68 .67 .66 .65
2 .75 .71 .67 .64 .73 .69.66 .63 .67 .64 .62 .65.62 .60 .63 .61 .59 .58
3 .70 .64 .59 .56 .68 .63.59 .55 .61 .57 .54 .59.56 .53 .57 .55 .52 .51
4 .64 .57 .52 .48 .63 .56.51 .47 .54 .50 .47 .53.49 .46 .51 .48 .46 .44
5 .59 .51 .45 .41 .58 .50.45 .41 .49 .44 .40 .47.43 .40 .46 .43 .40 .38
6 .54 .45 .39 .35 .53 .44.39 .35 .43 .38 .35 .42.38 .34 .41 .37 .34 .33
7 .49 .40 .34 .29 .48 .39.33 .29 .38 .33 .29 .37.32 .29 .36 .32 .29 .27
8 .44 .35 .28 .24 .43 .34.28 .24 .33 .28 .24 .32.27 .24 .31 .27 .24 .22
9 .40 .30 .24 .20 .39 .29.24 .20 .29 .23 .20 .28.23 .19 .27 .23 .19 .18
10 .35 .25 .18 .14 .34 .24.18 .14 .23 .18 .14 .23.18 .14 .22 .17 .14 .13
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 2.1
CERTILITE®V SERIES LIGHTING
PHOTOMETRIC DATA L131
L
Test No. HPK09915
METAL HALIDE, METAL HALIDE PULSE-
VM5
With Globe & Deep White Reflector
250-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
36000 lumens
For 250 MH multiply by 0.61
For 250 MHP multiply by 0.66
For 320 MHP multiply by 0.92
For 350 MHP multiply by 1.00
For 400 MHP multiply by 1.22
Efficiency 71.6%
ANGLE CP ANGLE CP
06298. 95.0 21.
5.0 6273. 100.0 26.
10.0 6354. 105.0 30.
15.0 6408. 110.0 35.
20.0 6542. 115.0 39.
25.0 6352. 120.0 42.
30.0 5943. 125.0 44.
35.0 6787. 130.0 45.
40.0 7215. 135.0 37.
45.0 6823. 140.0 33.
50.0 6732. 145.0 183.
55.0 6471. 150.0 35.
60.0 5358. 155.0 20.
65.0 2951. 160.0 12.
70.0 2049. 165.0 8.
75.0 1303. 170.0 0.
80.0 706. 175.0 0.
85.0 272. 180.0 0.
90.0 18.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .84 .84 .84 .84 .82 .82.82 .82 .79 .79 .79 .75.75 .75 .72 .72 .72 .70
1 .78 .74 .71 .69 .76 .73.70 .68 .70 .67 .65 .67.65 .63 .64 .63 .61 .60
2 .71 .66 .61 .57 .69 .64.60 .57 .62 .58 .55 .59.56 .54 .57 .55 .52 .51
3 .65 .58 .53 .48 .63 .57.52 .48 .55 .50 .47 .53.49 .46 .51 .48 .45 .44
4 .59 .51 .45 .40 .58 .50.44 .40 .48 .43 .39 .47.42 .39 .45 .41 .38 .37
5 .54 .45 .39 .34 .53 .44.38 .34 .43 .38 .34 .41.37 .33 .40 .36 .33 .31
6 .50 .40 .34 .29 .48 .40.34 .29 .38 .33 .29 .37.32 .28 .36 .31 .28 .27
7 .45 .36 .29 .25 .44 .35.29 .25 .34 .28 .24 .33.28 .24 .32 .27 .24 .23
8 .42 .32 .25 .21 .40 .31.25 .21 .30 .25 .21 .29.24 .21 .28 .24 .20 .19
9 .38 .28 .22 .18 .37 .28.22 .18 .27 .22 .18 .26.21 .18 .25 .21 .18 .16
10 .35 .25 .19 .15 .34 .24.19 .15 .24 .18 .15 .23.18 .15 .22 .18 .14 .13
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.6
Test No. HPK09914
METAL HALIDE, METAL HALIDE PULSE-
VM5
With Globe & Deep Alzak Reflector
250-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
36000 lumens
For 250 MH multiply by 0.61
For 250 MHP multiply by 0.66
For 320 MHP multiply by 0.92
For 350 MHP multiply by 1.00
For 400 MHP multiply by 1.22
Efficiency 70.8%
ANGLE CP ANGLE CP
03982. 95.0 9.
5.0 4067. 100.0 10.
10.0 4471. 105.0 10.
15.0 4949. 110.0 11.
20.0 5584. 115.0 10.
25.0 5932. 120.0 10.
30.0 5933. 125.0 10.
35.0 7123. 130.0 9.
40.0 7950. 135.0 8.
45.0 8017. 140.0 14.
50.0 8145. 145.0 173.
55.0 7441. 150.0 25.
60.0 5491. 155.0 16.
65.0 2411. 160.0 12.
70.0 1327. 165.0 7.
75.0 651. 170.0 0.
80.0 268. 175.0 0.
85.0 90. 180.0 0.
90.0 10.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .83 .83 .83 .83 .81 .81.81 .81 .78 .78 .78 .74 .74 .74 .71 .71 .71 .70
1 .77 .74 .71 .69 .75 .72.70 .68 .69 .67 .65 .67.65 .63 .64 .63 .61 .60
2 .71 .66 .61 .58 .69 .64.60 .57 .62 .58 .56 .59.57 .54 .57 .55 .53 .52
3 .65 .58 .53 .49 .63 .57.52 .48 .55 .51 .47 .53.49 .46 .51 .48 .46 .44
4 .59 .51 .45 .40 .57 .50.44 .40 .48 .43 .40 .47.42 .39 .45 .41 .38 .37
5 .54 .45 .39 .34 .52 .44.38 .34 .42 .37 .33 .41.36 .33 .40 .36 .32 .31
6 .49 .39 .33 .28 .47 .39.33 .28 .37 .32 .28 .36.31 .28 .35 .31 .27 .26
7 .44 .34 .28 .23 .43 .34.28 .23 .33 .27 .23 .31.27 .23 .30 .26 .23 .21
8 .40 .30 .24 .19 .39 .30.24 .19 .29 .23 .19 .28.23 .19 .27 .22 .19 .17
9 .37 .27 .21 .16 .36 .26.20 .16 .25 .20 .16 .25.20 .16 .24 .19 .16 .15
10 .33 .23 .17 .13 .32 .22.17 .13 .22 .16 .13 .21.16 .12 .20 .16 .12 .11
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 2.5
Test No. HPK09904
METAL HALIDE, METAL HALIDE PULSE-
VM5
With Enclosed Poly Shielded Reflector
250-400 Watt
Mogul Base
CANDLEPOWER –
400 WATT
36000 lumens
For 250 MH multiply by 0.61
For 250 MHP multiply by 0.66
For 320 MHP multiply by 0.92
For 350 MHP multiply by 1.00
For 400 MHP multiply by 1.22
Efficiency 63.4%
ANGLE CP ANGLE CP
07528. 95.0 542.
5.0 7607. 100.0 498.
10.0 7813. 105.0 463.
15.0 8263. 110.0 429.
20.0 8750. 115.0 365.
25.0 8768. 120.0 277.
30.0 7997. 125.0 174.
35.0 7518. 130.0 75.
40.0 7245. 135.0 12.
45.0 6107. 140.0 0.
50.0 4565. 145.0 0.
55.0 3680. 150.0 0.
60.0 2976. 155.0 0.
65.0 2334. 160.0 0.
70.0 1816. 165.0 0.
75.0 1408. 170.0 0.
80.0 1073. 175.0 0.
85.0 800. 180.0 .
90.0 614.
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .75 .75 .75 .75 .72 .72.72 .72 .68 .68 .68 .65.65 .65 .61 .61 .61 .59
1 .69 .66 .63 .61 .66 .64.61 .59 .60 .58 .57 .57.56 .54 .54 .53 .52 .50
2 .63 .59 .55 .51 .61 .57.54 .50 .54 .51 .49 .52.49 .47 .49 .47 .45 .44
3 .59 .53 .48 .44 .57 .51.47 .44 .49 .45 .43 .47.44 .41 .45 .42 .40 .39
4 .54 .47 .42 .38 .52 .46.41 .38 .44 .40 .37 .42.39 .36 .40 .37 .35 .34
5 .50 .43 .37 .34 .48 .42.37 .33 .40 .36 .33 .38.35 .32 .37 .34 .31 .30
6 .46 .39 .33 .30 .45 .38.33 .29 .36 .32 .29 .35.31 .28 .34 .30 .28 .27
7 .43 .35 .30 .26 .42 .34.29 .26 .33 .29 .26 .32.28 .25 .31 .27 .25 .23
8 .40 .32 .27 .23 .39 .31.26 .23 .30 .26 .23 .29.25 .22 .28 .24 .22 .21
9 .37 .29 .24 .21 .36 .28.24 .20 .27 .23 .20 .26.23 .20 .26 .22 .20 .18
10 .34 .25 .20 .17 .33 .25.20 .17 .24 .20 .17 .23.19 .16 .22 .19 .16 .15
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.5
E M L S E R I E S LIGHTING
EXPLOSION-PROOF LED 45 WATT
L132
FEATURES-SPECIFICATIONS
Certified - File LR11713
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
Suitable for wet locations
Marine
NEMA 3, 4, 4X
Factory Sealed
LED
Technology
Catalog Number Logic
Tank & Globe with
Driver and LEDs
EMLC — Tank w/Clear Globe
EML — Tank w/Fluted Globe
Wattage
45
Voltage
30 — 120-277VAC 50/60Hz
Mounting Type
A2 — 3/4" Pendant
A3 — 1" Pendant
X2 — 3/4" Ceiling
X3 — 1" Ceiling
B2 — 3/4" Bracket
B3 — 1" Bracket
D4 — 1-1/4" / 1-1/2"
Stanchion
Guard
G= Guard
EMLC 45 30 A2 G AN - ASSEMBLED
Applications
HOSTILELITE®EML LED Series fix-
tures are designed for installations
where moisture, dirt, dust, corrosion
and vibration may be present, or
NEMA 3 and 4x areas where wind,
water, snow or high ambients can be
expected. They can be used in loca-
tions made hazardous due to the pres-
ence of flammable or explosive gases,
vapors and combustible dusts as
defined by the NEC.
Applications include classified areas
such as paint manufacturing plants,
ammunition facilities, oil and gas pro-
ducing and refining plants, off-shore
and dockside installations, tank farms,
pipeline pumping stations and marine
loading and fuel transfer terminals.
Compliances
UL-8750 for LED lighting
UL-844 Electric Lighting Fixtures for
use in Hazardous Locations
UL Marine Type Electric Lighting
Fixtures
CSA C22.2 no. 137-M1981 Electric
Luminaires for use in Hazardous
Locations
NEMA 3, 4, 4X, 7CD, 9EFG
Materials
Ballast tank, splice box and guards
corrosion resistant copper-free alu-
minum alloy
Baked powder epoxy/polyester finish,
electrostatically applied for complete,
uniform corrosion protection
All external hardware - Stainless Steel
Reflectors are aluminum with white
finish
LED Luminaire Features and Standards
Compact Explosion-proof with Traditional
Industrial Appearance and Suitability
Fluted or Exclusive Clear Globe; Dome or
Angle Reflectors
Optional Mounting arrangements includ-
ing Pendant, Wall, Ceiling, and Stanchion
EML LED Housings can be retrofitted to
existing EZ splice boxes; upgrade from
Incandescent, Fluorescent or HID
Energy Savings - less than 50 Watts of
Power
Long Life - 50,000 - 55,000 Maintenance
Free Hours to 70% Initial Lumens
Crisp White Light for Excellent Color
Rendering - Chromaticity Avg. 495K
(CCT); 69 CRI
Ambient suitability -40°C to 5C
Instant on - including after power
interruption
World Voltage” 120-277VAC 50/60Hz
• Solder-LESS LED Board Connections –
Vibration Resistant
• Dual Drivers - Redundant Systems (built-
in backup)
LM80-08* Measurement of lumen mainte-
nance for LED light sources
LM79-08* Certified "Absolute" Photometry,
including Chromaticity Color for Solid
State Lighting
L70 Values - Industry Nomenclature for
Hours of use to 70% of Initial Lumens
Factory Sealed Construction - no external
seal required, simply wire mounting cap
and thread-in fixture to install
Accessories (sold separately)
ERSD30 — Dome Reflector
ERA30 — Angle Reflector
* LM-xx are Illumination Engineering Society Standards designed to promote uniformity in testing procedures among test
labs and manufacturers. For more information go to www.ies.org
LED
E M L S E R I E S LIGHTING
EXPLOSION - PROOF LED 45 WATT L133
ORDERING INFORMATION
L
Certified - File LR11713
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
Suitable for wet locations
Marine
NEMA 3, 4, 4X
Factory Sealed
Pendant Ceiling Wall Stanchion
EML SERIES PENDANT WITH OPTIC AND GUARD1
WATTS HUB SIZE2VOLTAGE4FLUTED GLOBE & GUARD CLEAR GLOBE & GUARD*
45 3/4" 120-277VAC EML4530A2G EMLC4530A2G
EML SERIES CEILING WITH OPTIC AND GUARD1
WATTS HUB SIZE2VOLTAGE4FLUTED GLOBE & GUARD CLEAR GLOBE & GUARD*
45 3/4" 120-277VAC EML4530X2G EMLC4530X2G
EML SERIES WALL WITH OPTIC AND GUARD1
WATTS HUB SIZE2VOLTAGE4FLUTED GLOBE & GUARD CLEAR GLOBE & GUARD*
45 3/4" 120-277VAC EML4530B2G EMLC4530B2G
EML SERIES 25OSTANCHION WITH OPTIC AND GUARD1
WATTS HUB SIZE3VOLTAGE4FLUTED GLOBE & GUARD CLEAR GLOBE & GUARD*
45 1-1/4"/1-1/2" 120-277VAC EML4530D4G EMLC4530D4G
1Catalog numbers shown are with Guard; Omit G if guard not required e.g. EML4530A2.
2Catalog numbers shown are with 3/4" conduit openings; change “2” to “3” for 1" e.g. EML4530A3G.
3Stanchion conduit hub size supplied is 1-1/2" with 1-1/2" to 1-1/4" reducer for 1-1/4" mounting (refer to catalog logic).
4120VAC through 277VAC 50/60Hz.
* Exclusive from KILLARK; clear globe for maximum brightness.
E M L S E R I E S LIGHTING
COMPONENT PARTS / ELECTRICAL & TEMPERATURE DATA
L134
Wall Bracket
Pendant Ceiling 25oStanchion
* 1-1/2" furnished with 1-1/2" - 1-1/4" reducer
HUB SIZE
3/4"
1"
1-1/4" / 1-1/2"*
CATALOG NUMBER
PENDANT CEILING WALL STANCHION
EZA2 EZX2 EZB2
EZA3 EZX3 EZB3
—— — EZD4*
EZ MOUNTING BRACKETS
EMG2
ERA30 Angle Dome
ERSD30 Standard Dome
DESCRIPTION
EML - EMLC LED ACCESSORIES
Guard1EMG2
Dome Reflector2ERSD30
Angle Reflector2ERA30
CIDI C2D1 N4X Photocell 120VAC VMHKPC1
CIDI C2D1 N4X Photocell 208-277VAC VMHKPC2
Replacement Fluted Globe & Support EMGS3
Replacement Clear Globe & Support EMGS2
Adapter to old Killark “H” Series or Crouse Hinds®EAC/EACH3
1Guards are cast of copper-free aluminum with electrostatically applied epoxy/polyester.
2Reflectors are aluminum with white finish.
3Adapters for discontinued Killark “H” Series and Crouse Hinds®available. See page L200 for more
information.
CAT. NO. VOLTAGE 50/60HZ WATTAGE AMPS 120/277 CIL4WEIGHT
EML(C) LED HOUSINGS & GLOBE, DRIVERS AND LEDS - ELECTRICAL RATINGS
EML(C)4530 120-277VAC 49.4 .412/.178 3960 26 LBS
CAT. NO. AMBIENT C1D1/C1Z1 C2D1 L70 SUPPLY WIRE
THERMAL PERFORMANCE DATA
EML(C)4530 40OC T6 T4A (EFG) 55,000 HRS 75OC
EML(C)4530 55OC T5 T4 (EFG) 50,000 HRS 90OC
4CIL = Calculated Initial Lumens of LED component based on mfg. data and driver current
INSIDE the optic. This value is provided as a reference only for comparison to traditional
light sources such as incandescent, HID, or fluorescent which use initial values in “relative”
photometry. KILLARK LED luminaires are tested using the Absolute photometry method
(LM79-08), which calculates delivered lumens only. KILLARK’s LED luminaires provide very
bright white 5000O K (CCT) color and can appear brighter than traditional light sources
with higher lumen values under both photopic and scotopic conditions.
EML4530
EMLC4530
Factory Sealed
Photocell VMHKPC1
EMGS3
EMGS2
EAC/EACH
CATALOG NUMBER
E M L S E R I E S LIGHTING
DIMENSIONS / PHOTOMETRIC DATA L135
L
Pendant Ceiling LED 45 Watt Fluted Globe Only
Wall
25° Stanchion
.31"
(8)
4.25"
(107)
4.75"
(120)
7.00"
(177)
5.25"
(133)
45°
TYPE ABCD
EML(C) DIMENSIONS1
1See L143 for reflector dimensions.
Pendant 15-15/16" 15-1/16" 8-13/16" 11-15/16"
(404) (382) (224) (303)
Ceiling 15-15/16" 15-1/16" 8-13/16" 11-15/16"
(404) (382) (224) (303)
Wall 16-13/16" 15-15/16" 15" 11-15/16"
(426) (404) (379) (303)
Stanchion 15-1/8" 14" 13-1/2"
(384) (356) (343)
E M L S E R I E S LIGHTING
PHOTOMETRIC DATA
L136
LED 45 Watt Fluted
Globe & Dome Reflector
LED 45 Watt Fluted
Globe & Angle Reflector
LED 45 Watt Clear
Globe & Dome Reflector
EM/EB/EQ SERIES LIGHTING
INCANDESCENT/COMPACT FLUORESCENT/MEDIUM BASE HID L137
FEATURES-SPECIFICATIONS
L
Listed - Files E10514 and
E91793 (Marine)
Certified - File LR11713
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
Suitable for wet locations
Marine
NEMA 3, 4, 4X
Factory Sealed
Catalog Number Logic
Series Constant
Lamp Base
M—Medium Base
B—Bi-Pin Base
Q—Quad-Pin Base
Lamp Type
I—Incandescent
F—Fluorescent (lamp included)
S—HPS
H—MH
Voltage @ 60 Hertz
0—Quadri-Volt
(120, 208, 240, 277)
1—120
4—277
5—480
6—347 Canada (70,100MH/HPS)
30—120-277 50/60 Hz
EQF Series Only
Mounting Type
A2—3/4" Pendant
A3—1" Pendant
X2—3/4" Ceiling
X3—1" Ceiling
B2—3/4" Bracket
B3—1" Bracket
D4—1-1/4"/1-1/2" Stanchion
Lamp Wattage
15—150W, A-21, INC
20—300W, PS-25, INC
30—300W, PS-30, INC
13—(1) 13W, Bi-Pin FLUOR
26—(2) 13W Bi-Pin EBF or (1) Quad-Pin
EQF 26 Watt FLUOR
32—Quad-Pin FLUOR
42—Quad-Pin FLUOR
52—Quad-Pin FLUOR (2 X 26)
64—Quad-Pin FLUOR (2 X 32)
84—Quad-Pin FLUOR (2 X 42)
35—35W, HPS
05—50W, HPS, MH
07—70W, HPS, MH
10—100W, HPS, MH
15—150W, HPS
Guard
G—Omit G if guard is not
required
Options
ML—UL Marine Listing for
EMI. Standard on EMS,
EMM and EMH.
Not available on
EBF, EQF
SU103—Assembled w/Lamp
E 0 0 00 0 00 0 - 00 (CEN)*
Applications
HOSTILELITE®EM, EB, & EQ Series
fixtures are designed for installations
where moisture, dirt, dust, corrosion
and vibration may be present, or
NEMA 3 and 4x areas where wind,
water, snow or high ambients can be
expected. They can be used in loca-
tions made hazardous due to the
presence of flammable or explosive
gases, vapors and combustible dusts
as defined by the NEC.
Applications include classified areas
such as paint manufacturing plants,
ammunition facilities, oil and gas pro-
ducing and refining plants, off-shore
and dockside installations, tank farms,
pipeline pumping stations and marine
loading and fuel transfer terminals.
Features:
Four light sources—Incandescent,
compact fluorescent, high pressure
sodium and metal halide
Mounting choice—Pendant, ceiling,
25˚ stanchion or 90˚ wall mount, all
with “wireless” design that allows
fast, easy fixture installation
Factory sealed—No external seal
needed. Simply wire mounting cap
and thread on fixture to install
Compact size—Medium base
incandescent and HID lamps, plus
PL fluorescent lamps allow smaller
fixture design
Corrosion resistant—Copper-free
aluminum die-cast construction.
Baked powder epoxy finish, electro-
statically applied. Exposed hardware
is 316 grade stainless steel
Accessories
Available with or without guard, stan-
dard dome or 25˚ angle reflector, exit
sign and inner colored globes
Compliances
UL-844 Electric Lighting Fixtures for
use in Hazardous Locations
UL Marine Type Electric Lighting
Fixtures
UL-1598 Standard for Fluorescent,
Incandescent and HID fixtures
CSA C22.2 no. 137-M1981 Electric
Luminaires for use in Hazardous
Locations
NEMA 3, 4, 4X, 7CD, 9EFG
*CEN (CENELEC) approval option available on certain models. See page L144 for more information.
Consult factory for available lamp and voltage combinations.
V
V
L138
FEATURES-SPECIFICATIONS
Listed - Files E10514 and
E91793 (Marine)
Certified - File LR11713
EM 60–300W MEDIUM BASE INCANDESCENT1
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
Suitable for wet locations
Marine
NEMA 3, 4, 4X
Factory Sealed
LAMP LAMP/WATTS LAMP SIZE CATALOG NUMBER4
TYPE PENDANT 3/4"2CEILING 3/4"2WALL 3/4"2STANCHION 1-1/4"3
EMI15A2G
EMI20A2G
EMI30A2G
EMI15X2G
EMI20X2G
EMI30X2G
EMI15B2G
EMI20B2G
EMI30B2G
EMI15D4G
EMI20D4G
EMI30D4G
60, 75, 100, 150 A-19, A-21
INC 100, 150, 200, 300 A-23, PS-25
200, 300 PS-25, PS-30
EQF 26-42W WORLD VOLTAGE QUAD-PIN COMPACT FLUORESCENT1
Quad-Pin FLUORESCENT CATALOG NUMBER4
LAMP INCLUDED LINE VOLTAGE PENDANT 3/4"2CEILING 3/4"2WALL 3/4"2STANCHION 1-1/4"3
EQF2630A2G
EQF3230A2G
EQF4230A2G
EQF5230A2G
EQF6430A2G
EQF8430A2G
EQF2630X2G
EQF3230X2G
EQF4230X2G
EQF5230X2G
EQF6430X2G
EQF8430X2G
EQF2630B2G
EQF3230B2G
EQF4230B2G
EQF5230B2G
EQF6430B2G
EQF8430B2G
EQF2630D4G
EQF3230D4G
EQF4230D4G
EQF5230D4G
EQF6430D4G
EQF8430D4G
26 Watt5120-277VAC 50-60Hz
32 Watt 5120-277VAC 50-60Hz
42 Watt 5120-277VAC 50-60Hz
52 Watt (2 X 26) 120-277VAC 50-60Hz
64 Watt (2 X 32) 120-277VAC 50-60Hz
84 Watt (2 X 42) 120-277VAC 50-60Hz
EBF 13-26W Bi-Pin COMPACT FLUORESCENT1
LAMP Bi-Pin FLUORESCENT CATALOG NUMBER4
TYPE LAMP INCLUDED LINE VOLTAGE @60Hz PENDANT 3/4"2CEILING 3/4"2WALL 3/4"2STANCHION 1-1/4"3
120
13 (1 X 13) 277
26 (2 X 13) 120
277
EBF131A2G
EBF134A2G
EBF261A2G
EBF264A2G
EBF131X2G
EBF134X2G
EBF261X2G
EBF264X2G
EBF131B2G
EBF134B2G
EBF261B2G
EBF264B2G
EBF131D4G
EBF134D4G
EBF261D4G
EBF264D4G
1See Hazardous Location Application Data on pages L144-145 for specific suitabilities.
2For 1" pendant, ceiling and wall hubs, substitute “3” for “2” in catalog number; example: EBF131A3G.
3Stanchion conduit hub size supplied is 1-1/2" with 1-1/2" to 1-1/4" reducer for 1-1/4" mounting. (refer to catalog logic).
4Luminaire catalog numbers include guards. To order luminaire without guard, omit last letter “G” from catalog number.
5EQF 26-42 Watt fixtures use a tank extension ring and are 2.5" taller than EBF fixtures.
NOTE: Reflectors must be ordered separately (see page L140). All luminaires are designed for mounting with lamp in
base up position.
Pendant Ceiling Wall Stanchion
COMPACT
FLUOR.
COMPACT
FLUOR.
LAMP
TYPE
EM/EB/EQ SERIES L I G H T I N G
INCANDESCENT, 60-300W MEDIUM BASE; COMPACT FLUORESCENT, 13-84W
EM/EB/EQ SERIES LIGHTING
HID, 35-150W MEDIUM BASE L139
FEATURES-SPECIFICATIONS
Listed - Files E10514 and
E91793 (Marine)
Certified - File LR11713
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
Suitable for wet locations
Marine
NEMA 3, 4, 4X
Factory Sealed
Pendant Ceiling Wall Stanchion
1See Hazardous Location Application Data on page L144-145 for specific suitabilities.
2For 1" pendant, ceiling and wall hubs, substitute “3” for “2” in catalog number; example: EMS351A3G.
3Stanchion conduit hub size supplied is 1-1/2" with 1-1/2" to 1-1/4" reducer for 1-1/4" mounting. (refer to catalog logic).
4Luminaire catalog numbers include guards. To order luminaire without guard, omit last letter “G” from catalog number.
NOTE: Reflectors must be ordered separately (see page L140). All luminaires are designed for mounting with lamp in base
up position.
EMS351A2G
EMS050A2G
EMS070A2G
EMS075A2G
EMS100A2G
EMS105A2G
EMS151A2G
EMH050A2G
EMH070A2G
EMH100A2G
EMH050X2G
EMH070X2G
EMH100X2G
EMH050B2G
EMH070B2G
EMH100B2G
EMH050D4G
EMH070D4G
EMH100D4G
EMS351X2G
EMS050X2G
EMS070X2G
EMS075X2G
EMS100X2G
EMS105X2G
EMS151X2G
EMS351B2G
EMS050B2G
EMS070B2G
EMS075B2G
EMS100B2G
EMS105B2G
EMS151B2G
EMS351D4G
EMS050D4G
EMS070D4G
EMS075D4G
EMS100D4G
EMS105D4G
EMS151D4G
35 S-76 120
50 S-68 120, 208, 240, 277
70 S-62 120, 208, 240, 277
HPS 70 S-62 480
100 S-54 120, 208, 240, 277
100 S-54 480
150 S-55 120
EM 35-150W MEDIUM BASE HIGH PRESSURE SODIUM1 4
LAMP LAMP ANSI VOLTAGE CATALOG NUMBER4
TYPE WATTS LAMP TYPE @60 HERTZ PENDANT 3/4"2CEILING 3/4"2WALL 3/4"2STANCHION 1-1/4"3
50 M-110 120, 208, 240, 277
MH 70 M-98 120, 208, 240, 277
100 M-90 120, 208, 240, 277
EM 50-100W MEDIUM BASE METAL HALIDE1 4
LAMP LAMP ANSI VOLTAGE CATALOG NUMBER4
TYPE WATTS LAMP TYPE @60 HERTZ PENDANT 3/4"2CEILING 3/4"2WALL 3/4"2STANCHION 1-1/4"3
L
EM/EB/EQ SERIES LIGHTING
COMPONENT PARTS/ACCESSORIES
L140
Housing, Globe and
Globe Support Assemblies1
Angle DomeStandard Dome
SERIES LAMP TYPE
EMI15 INC
EMI20 INC
EBF Bi-Pin
EQF (26, 32, 42) Quad-Pin
EMI30 INC
EMS HPS
EMH MH
ESX Strobe
EQF (52, 64, 84) Quad-Pin
CATALOG
NUMBER
EMG1
EMG2
GUARDS
Guards are cast of copper-free aluminum with
electrostatically applied epoxy/polyester finish.
1Assemblies may be ordered with the
CEN (CENELEC) suffix. See page L144 for
more information.
2Adapters for discontinued Killark “H” Series
and Crouse Hinds®available. See page L224
for more information.
3UL fixture rating; socket rated 600V.
* Consult factory for 52, 64 and 84 Watt
availability.
HUB SIZE
3/4"
1"
1-1/4"/1-1/2"*
CATALOG NUMBER
PENDANT CEILING BRACKET STANCHION
EZA2 EZX2 EZB2
EZA3 EZX3 EZB3
—— — EZD4*
MOUNTING BOXES
Wall Bracket 25° Stanchion
SERIES
EMI15/EMI20
EBF
EQF
EMI30
EMS
EMH
EQF (52, 64, 84)
CATALOG NUMBER
STANDARD DOME ANGLE
ERSD15 ERA15
ERSD30 ERA30
REFLECTORS
VOLTS3
250 MAX.
VAC
250 MAX.
VAC
250 MAX.
VAC
INCANDESCENT
CATALOG
NUMBER
EMI15
EMI20
EMI30
LAMP TYPE
A-19
A-19, A-21
A-21
A-23, PS-25
A-23, PS-25
PS-25
PS-25
PS-30
WATTS
60, 75
100
150
150
200
300
200
300
HPS
CATALOG
NUMBER
EMS351
EMS050
EMS070
EMS075
EMS100
EMS105
EMS151
WATTS
35
50
70
100
150
VOLTS
120VAC
277VAC
120VAC
277VAC
120-277
VAC
50-60Hz
VOLTS
@60HZ.
120
Quadri-Volt
Quadri-Volt
480
Quadri-Volt
480
120
FLUORESCENT with lamp(s)*
CATALOG
NUMBER
EBF131
EBF134
EBF261
EBF264
EQF2630
EQF3230
EQF4230
EQF5230
EQF6430
EQF8430
ANSI
LAMP TYPE
S-76
S-68
S-62
S-54
S-55
ANSI
LAMP TYPE
Bi-Pin
Fluorescent
Bi-Pin
Fluorescent
Quad Pin
Fluorescent
WATTS
13
26 (2x13)
26
32
42
52 (2X26)
64 (2X32)
84 (2X42)
VOLTS
@60HZ.
Quadri-Volt
Quadri-Volt
Quadri-Volt
METAL HALIDE
CATALOG
NUMBER
EMH050
EMH070
EMH100
ANSI
LAMP TYPE
M-110
M-98
M-90
WATTS
50
70
100
Pendant Ceiling
EMG1 EMG2 EAC2
Listed - Files E10514 and
E91793 (Marine)
Certified - File LR11713
EMI15/20/EBF EMI30 & HID
Reflectors are aluminum with white finish.
*1-1/2" furnished with 1-1/2"-1-1/4" reducer
EZCUP
Close up plug for
EZ mounting
boxes. Used for
maintenance when
fixture is removed
for service.
HIC-BEIGE
replacement
wiring plug
for EZBx
Wall Bracket
FACTORY SEALED
PHOTO CELL FIELD KITS
WITH HKB-GL BOX AND COVER
VMHKPC1
VMHKPC2
VMHKPC3
CATALOG NUMBER
120VAC
208-277VAC
347VAC
VOLTS
Class I, DIV. 1 BCD
Class II, DIV. 1&2 EFG
CLASS III
NEMA 3, 4X IP66
*40˚C ambient T3 Rated
EM/EB/EQ SERIES LIGHTING
REPLACEMENT PARTS/ACCESSORIES L141
L
Hazardous Locations Exit Sign
Applications
For use in hazardous areas to mark
exits over doorways and in hallways.
Features
Three sided illuminated sign visible
from all three sides
EXIT printed in 6" high red letters
with 3/4" strokes as required by
OSHA. Sign has open bottom
providing light on exit area while
illuminating the panel
Replacement Globe & Support Assemblies
Exit Sign Accessory
KIT NO. GLOBE COLOR
KT-100SU41R RED
KT-100SU41G GREEN
Used to modify EMI20 Series only fixtures to accept a colored inner
globe. The kit includes the globe plus an adapter assembly and
mounting instructions.
2Maximum lamp size A-21 150 Watt.
COLORED GLOBE KITS FOR HAZARDOUS LOCATIONS2
EM Series EB Series
SERIES LAMP TYPE MAX. WATTAGE
EMI15 INC 150
EMI20 INC 300
EBF13/26 PL Bi-Pin Fluorescent 26
EQF PL Quad-Pin Fluorescent 26, 32, 42
EMI30 INC 300
EMS HPS 150
EMH MH 100
EQF PL Quad-Pin Fluorescent 52, 62, 84
CATALOG NUMBER1
EMGS1
EMGS22
EMGS3
REPLACEMENT GLOBE AND GLOBE SUPPORTS
REPLACEMENT CONNECTION BLOCKS
CATALOG NUMBER
EZTB
EZCB
DESCRIPTION
Female
Male
REPLACEMENT SOCKETS
CATALOG NUMBER
EMRS
EBRS
DESCRIPTION
EM Series E-26 Medium Base
EB Series
EXIT SIGN
CATALOG NUMBER
HEXA-100
DESCRIPTION
Fits EMI15, EMI20, EBF/EQF/EEQ
Series without guard *
(Fixture not included)
1EMGS1, EMGS3 are internally fluted glass.
2EMGS2 is smooth clear glass used for ESX strobe.
MPL13 13W Bi-Pin
MQL26 26W Quad-Pin
MQL32 32W Quad-Pin
MQL42 42W Quad-Pin
REPLACEMENT FLUORESCENT LAMPS
CATALOG NUMBER SIZE & TYPE
* EQF to 42W
Male
EZCB
Female
EZTB
EM/EB/EQ SERIES LIGHTING
BALLAST DATA
L142
LAMP LAMP OPERATING OPEN
SOURCE WATTS/TYPE (AMPS) (AMPS) BALLAST CIRCUIT REGULATION MIN, START
(1) Bi-Pin .39
Fluorescent 13W (1 X 13) .35 .30 NPF 32°F (0°C)
(2) Bi-Pin .78
Fluorescent 26W (2 X 13) .70 .60 NPF 32°F (0°C)
0°F (-18°C)
0°F (-18°C)
HPS 35W S-76 .55 .40 .65 R-HPF1±5% Line Voltage* 0°F (-40°C)
.58 .58 1.24
HPS 50W S-68 .35 .33 .59
.30 .29 .50 HX-HPF1±5% Line Voltage* 0°F ( -40°C)
.24 .25 .44
.75 .81 1.45
.45 .47 .85
HPS 70W S-62 .37 .40 .75 HX-HPF1±5% Line Voltage* 0°F (-40°C)
.35 .35 .65
.21 .21 .36
1.30 1.15 2.20
.76 .66 1.27
.66 .57 1.10 HX-HPF1±5% Line Voltage* 0 ° F (- 4 0 ° C)
HPS 100W S-54 .60 .49 .85
.33 .28 .57
HPS 150W S-55 2.20 1.50 2.35 HX-HPF1±5% Line Voltage* 0°F (-40°C)
.87 .60 1.16
MH 50W M-110 .51 .35 .67 HX-HPF1±5% Line Voltage -20°F (-30°C)
.47 .30 .5 7 ±12% Lamp Watts
.39 .25 .50
.80 .85 1.70
MH 70W M-98 .50 .50 1.04 HX-HPF1±5% Line Voltage -20°F (-30°C)
.43 .43 .8 7 ±12% Lamp Watts
.39 .37 .78
1.20 1.15 2.30
MH 100W M-90 .70 .60 1.30 HX-HPF1±5% Line Voltage -20°F (-30°C)
.61 .55 1.10 ±12% Lamp Watts
.55 .45 .95
EM/EB BALLAST DATA
* Lamp watts within ANSI Trapezoid limitations.
1Ballast circuits are High Power Factor 90%+.
START
(AMPS)
Quad-Pin
Fluorescent
26W
32W
42W
120-277
Quad-Pin
Fluorescent
52W (2X26)
64W (2X36)
84W (2X42)
120-277
.24(120)/.11(277)
.31(120)/.13(277)
.38(120)/.18(277)
HPF
.48(120)/.22(277)
.62(120)/.26(277)
.76(120)/.36(277)
— —
ELECTRONIC
ELECTRONIC
HPF
VOLTAGE @
60 HERTZ
120
277
120
277
120
120
208
240
277
120
208
240
277
480
120
208
240
277
480
120
120
208
240
277
120
208
240
277
120
208
240
277
EM/EB/EQ/ESX/EEQ SERIES LIGHTING
DIMENSIONS L143
FEATURES-SPECIFICATIONS
L
Pendant Ceiling Wall Stanchion
Pendant Ceiling Wall 25° Stanchion
PENDANT CEILING WALL STANCHION
SERIES A B C D A B C D A B C D A B C
EMI15
EMI20 14-5/16" 13-11/16" 7-7/16" 10-5/16" 14-5/16" 13-11/16" 7-7/16" 10-5/16" 15-13/16" 14-7/16" 14-1/2" 10-5/16" 14" 13-1/4" 13"
EBF13 (363) (346) (188) (261) (363) (347) (188) (261) (385) (366) (369) (26) (256) (337) (330)
EBF26
16-13/16" 16-3/16" 7-7/16" 12-5/8" 16-13/16" 16-3/16" 7-7/16" 12-5/8" 18-5/16" 16-15/16" 14-1/2" 12-5/8" 16-1/4" 15-3/4" 15-1/4"
(427) (411) (188) (321) (427) (411) (188) (321) (465) (430) (368) (321) (413) (400) (387)
EMI30
EMH 15-15/16" 15-1/16" 8-13/16" 11-15/16" 15-15/16" 15-1/16" 8-13/16" 11-15/16" 16-13/16" 15-13/16" 15" 11-15/16" 15-1/8" 14" 13-1/2"
EMS (404) (382) (224) (303) (404) (382) (224) (303) (426) (404) (379) (303) (384) (356) ( 343)
ESX
EQF 52, 64, 84
EM/EMB/ESX DIMENSIONS
Standard Dome
Angle
STANDARD DOME ANGLE
SERIES AB CABCD
7-3/8" 14" 3-3/4" 7" 11-1/2" 7-3/4" 1"
(187) (356) (95) (178) (292) (197) (25)
8-3/4" 16-1/8" 3-15/16" 8-3/4" 14-3/16" 7-3/4" 1"
(222) (409) (100) (222) (360) (197) (25)
REFLECTOR DIMENSIONS
.31"
(8)
4.25"
(107)
4.75"
(120)
7.00"
(177)
45°
EMI15/EMI20
EBF/EQF to 42W
EMI30/EMS
EMH
EQF 52, 64, 84
EQF to 42W
EEQ
5.25"
(133)
EM/EB/EQ SERIES LIGHTING
A P P L I C AT I O N D ATA
L144
EM/EB/EQ HAZARDOUS LOCATION DATA–CLASS I, DIV. 1 & 21 2
SUPPLY CLASS I, DIVISIONS 1 & 2
WIRE MAXIMUM SURFACE TEMPERATURE °CLAMP RATED
SUITABLE UL/CSA
FIXTURE TYPE/SIZE LAMP AMBIENT
FOR °C WITH OR WITHOUT REFLECTOR
SERIES MAX. WATTS °C
MIN. TEMP. I.D. ACTUAL TEMP. UL/CSA GROUPS
40 75 T6 79 C,D
EMI15 INC A-19 60 55 75 T6 C,D
65 75 T4A C,D
40 75 T4A 103 C,D
EMI15 INC A-19 75 55 90 T4A C,D
65 90 T4 C,D
40 75 T4A 103 C,D
EMI15 INC A-19 100 55 90 T4A C,D
65 90 T4 C,D
40 75 T4A 101 C,D
EMI15 INC A-21 100 55 90 T4A C,D
65 90 T4 C,D
40 75 T4 123 C,D
EMI15 INC A-21 150 55 90 T3C C,D
65 90 T3C C,D
40 90 T4A 107 C,D
EMI20 INC A-23 100 55 90 T4 C,D
65 90 T4 C,D
40 90 T4 132 C,D
EMI20 INC A-23 150 55 90 T3C C,D
65 111 T3C C,D
40 90 T4 126 C,D
EMI20 INC PS-25 150 55 110 T3C C,D
65 110 T3C C,D
40 90 T3C 146 C,D
EMI20 INC A-23 200 55 90 T3B C,D
65 110 T3A C,D
40 90 T3C 154 C,D
EMI20 INC PS-25 200 55 90 T3A C,D
65 110 T3A C,D
40 90 T3 190 C,D
EMI20 INC PS-25 300 55 110 T2D C,D
65 C,D
40 110 T3C 146 C,D
EMI30 INC PS-25 200 55 110 T3B C,D
65 125 T3A C,D
40 110 T3C 143 C,D
EMI30 INC PS-25 300 55 110 T3B C,D
65 125 T3A C,D
40 110 T3C 146 C,D
EMI30 INC PS-30 200 55 110 T3B C,D
65 125 T3A C,D
40 110 T3C 146 C,D
EMI30 INC PS-30 300 55 110 T3B C,D
65 125 T3A C,D
40 75 T6 62 C,D
EBF13 1 13W Bi-Pin 13 55 9 0 T6 C, D
65 90 T5 C,D
40 75 T6 62 C,D
EBF26 2 13W Bi-Pin 26 55 9 0 T6 C, D
65 90 T5 C,D
EQF26 1 26W Quad-Pin 26 4 0 75 T6 75 C,D
EQF32 1 32W Quad-Pin 32 4 0 75 T6 75 C,D
EQF42 1 42W Quad-Pin 42 4 0 75 T6 75 C,D
EQF52 2 26W Quad-Pin 52 4 0 75 T6 85 C,D
EQF64 2 32W Quad-Pin 64 40 75 T6 85 C,D
EQF84 2 42W Quad-Pin 84 4 0 75 T6 85 C,D
40 75 T6 65 C,D
EMS35 HPS S-70 35 55 90 T5 C,D
65 90 T4A C,D
40 75 T6 68 C,D
EMS05 HPS S-68 50 55 75 T6 C,D
65 90 T5 C,D
40 75 T6 83 C,D
EMS07 HPS S-62 70 55 90 T5 C,D
65 90 T4A C,D
40 75 T5 99 C,D
EMS100 HPS S-54 100 55 90 T4A C,D
65 110 T4A C,D
40 75 T4A 119 C,D
EMS151 HPS S-55 150 55 90 T4 C,D
65 110 T3C C,D
40 75 T6 78 C,D
EMH05 MH M-110 50 55 90 T5 C,D
65 110 T4A C,D
40 75 T5 95 C,D
EMH07 MH M-98 75 55 90 T4A C,D
65 110 T4A C,D
40 75 T4A 101 C,D
EMH100 MH M-90 100 55 90 T4 C,D
65 110 T3C C,D
1Do not install where marked operating temperature exceeds
ignition temperature of hazardous atmosphere.
2See Class II table for simultaneous presence ratings.
CEN Option
Applications
Killark EM/EB/ESX series fixtures are
available with a European “Certificate of
Conformity” from PTB (Physikalisch-
Technische Bundesanstalt), the approval
agency based in Germany. Fixtures with
this rating will be useful for Original
Equipment Manufacturers and others
who build and ship apparatus into
European markets.
This approval is granted by PTB with the
use of a special ground lug and label.
Fixtures carrying an EEx d llB approval
are automatically granted an IP54
(ingress protection) rating. See
Temperature Code chart below for PTB
certified ratings. Killark EM/EB/ESX
fixtures with the PTB rating and labels
still carry all UL & CSA ratings.
Fixture housing/globe/globe support
assemblies (e.g. EM120 CEN) may be
ordered with the CEN suffix. Complete
fixture numbers, with the CEN suffix, will
be shipped with the mounting boxes,
guards and accessories as component
parts. Reflectors and other accessory
parts, as listed on pages L123-124, may
be used. Killark fixtures are NPT tapped
and plugged with at least one conduit
hole open.
Compliances
EN 50014:1992
EN 50018:1994
EEx d IIB T6 (or T5-T2)
PTB No. Ex-98.E.1076
MAXIMUM AMBIENT TEMPERATURE RANGE -20°C TO 40°C
TYPE OF
LUMINAIRE
EMI15
EMI20
EMI30
EMH05
EMH07
EMH10
EMS35
EMS05
EMS07
EMS10
EMS15
EBF13
EBF26
ESX( )120
ESX( )240
ESX( )1274
TYPE OF
ENCLOSURE
EMO20
EMO20
EMO30
EMO30
EMO30
EMO30
EMO30
EMO30
EMO30
EMO30
EMO30
EMO20
EMO20
EMO30
EMO30
EMO30
FORM OF
THE LAMP
A-19/A-21
A-23/PS-25
PS-25/PS-30
BD17/M-110
BD17/M-98
BD17/M-90
ED17/S-76
ED17/S-68
ED17/S-62
ED17/S-54
ED17/S-55
PL13
PL13
120V AC
240V AC
12 TO 74 V DC
MAXIMUM
WATTAGE
150W
300W
300W
50W
70W
100W
35W
50W
70W
100W
150W
13W
26W
0.17 A
0.12 A
1.25 TI 0.2 A
TEMPERATURE
CLASS
T4
T3
T2
T6
T5
T4
T6
T6
T5
T5
T4
T6
T6
T6
T6
T6
EM/EB/EQ SERIES LIGHTING
A P P L I C AT I O N D ATA L145
L
CLASS II, DIV. 1 & 2
SUPPLY MAXIMUM SURFACE TEMPERATURE °C
FIXTURE LAMP LAMP RATED WIRE UL/CSA UL/CSA UL/CSA
CLASS III UL/CSA UL/CSA
SERIES TYPE/SIZE WATTS AMBIENT SUITABLE WITHOUT REFLECTOR WITH REFLECTOR GROUPS
DIV. 1 & 2 UL U.L. PAINT TYPE 3 TYPE 4
MAX. °C FOR °C ACTUAL ACTUAL
UL/CSA MARINE SPRAY (RAIN- (HOSE-
MIN. TEMP. I.D. TEMP. °C TEMP. I.D. TEMP. °C
SUITABILITY LISTEDSUITABILITY TIGHT) DOWN)3
40 75 T3C 132 T3C 132 E,F,G YES YES NO YES YES
EMI15 INC A-19 60 55 75 T3A E,F NO YES NO YES YES
65 75 T3A E,F NO
40 75 T3A 163 T3A 162 E,F NO YES NO YES YES
EMI15 INC A-19 75 55 90 T3A T3A E,F NO YES NO YES YES
65 90 T3A T3A E,F NO YES NO YES YES
40 75 T3A 163 T3A 162 E,F NO YES NO YES YES
EMI15 INC A-19 100 55 90 T3A T3A E,F NO YES NO YES YES
65 90 T3A T3 E,F NO YES NO YES YES
40 75 T3A 172 T3A 172 E,F NO YES NO YES YES
EMI15 INC A-21 100 55 90 T3 E,F NO YES NO YES YES
65 90 T3 E,F NO YES NO YES YES
40 75 N/A 192 T3 192 E,F NO YES NO YES YES
EMI15 INC A-21 150 55 N/A
65 N/A
40 90 T3A 166 T3A 166 E,F NO YES NO YES YES
EMI20 INC A-23 100 55 90 T3 E,F NO YES NO YES YES
65 N/A
40 90 T3 196 T3A 178 E,F NO YES NO YES YES
EMI20 INC A-23 150 55 90 T3 E,F NO YES NO YES YES
65 N/A
40 90 N/A N/A N/A N/A NO NO YES NO YES YES
EMI20 INC PS-25 150 55 N/A
65 N/A
40 90 N/A N/A N/A N/A NO NO YES NO YES YES
EMI20 INC A-23 200 55 N/A
65 N/A
40 90 N/A N/A N/A N/A NO NO YES NO YES YES
EMI20 INC PS-25 200 55 N/A
65 N/A
40 90 N/A N/A N/A N/A NO NO YES NO YES YES
EMI20 INC PS-25 300 55 N/A
65 N/A
40 110 N/A N/A N/A N/A NO NO YES NO YES YES
EMI30 INC PS-25 200 55 N/A
65 N/A
40 110 N/A N/A N/A N/A NO NO YES NO YES YES
EMI30 INC PS-25 300 55 N/A
65 N/A
40 110 N/A N/A N/A N/A NO NO YES NO YES YES
EMI30 INC PS-30 200 55 N/A
65 N/A
40 110 N/A N/A N/A N/A NO NO YES NO YES YES
EMI30 INC PS-30 300 55 N/A
65 N/A
40 75 T6 69 T6 66 E,F,G YES NO YES YES YES
EBF13 1 13W Bi-Pin 13 55 90 T6 T6 E,F,G YES NO YES YES YES
65 90 T5 T5 E,F,G YES NO YES YES YES
40 75 T6 69 T6 66 E,F,G YES NO YES YES YES
EBF26 2 13W Bi-Pin 26 55 90 T6 T6 E,F,G YES NO YES YES YES
65 90 T5 T5 E,F,G YES NO YES YES YES
EQF26 1 26W Quad-Pin 26 40 75 T4 135 T4 135 E,F,G YES NO YES YES YES
EQF32 1 32W Quad-Pin 32 40 75 T4 135 T4 135 E,F,G YES NO YES YES YES
EQF42 1 42W Quad-Pin 42 40 75 T4 135 T4 135 E,F,G YES NO YES YES YES
EQF52 2 26W Quad-Pin 52 40 75 T4 135 T4 135 E,F,G YES NO YES YES YES
EQF64 2 32W Quad-Pin 64 40 75 T4 135 T4 135 E,F,G YES NO YES YES YES
EQF84 2 42W Quad-Pin 84 40 75 T4 135 T4 135 E,F,G YES NO YES YES YES
40 75 T4A 116 T4A 116 E,F,G YES YES YES YES YES
EMS35 HPS S-70 35 55 N/A
65 N/A
40 75 T4A 116 T4A 116 E,F,G YES YES YES YES YES
EMS05 HPS S-68 50 55 75 T4 E,F,G
65 90 T3C E,F,G
40 75 T4A 116 T4A 116 E,F,G YES YES YES YES YES
EMS07 HPS S-62 70 55 90 T4 E,F,G YES YES YES YES YES
65 90 T3C E,F,G YES YES YES YES YES
40 75 T3B 161 T3B 161 E,F,G YES YES NO YES YES
EMS100 HPS S-54 100 55 N/A
65 N/A
40 75 T3A 180 T3B 180 E,F NO YES NO YES YES
EMS150 HPS S-55 150 55 90 T3 T3A E,F NO YES NO YES YES
65 N/A
40 75 T4 121 T4 121 E,F,G YES YES YES YES YES
EMH05 MH M-110 50 55 90 T3C T3A E,F NO YES YES YES YES
65 110 T3B T3A E,F,G NO YES YES YES YES
40 75 T4 121 T4 121 E,F,G YES YES YES YES YES
EMH07 MH M-98 70 55 90 T3C T3C E,F,G YES YES YES YES YES
65 110 T3B T3C E,F,G YES YES YES YES YES
40 75 T3C 153 T3C 153 E,F,G YES YES NO YES YES
EMH100 MH M-90 100 55 90 T3A NO YES YES NO YES YES
65 N/A
1Do not install where marked operating temperature exceeds ignition temperature of hazardous atmosphere.
2Fixtures rated for simultaneous presence as shown in Class II table (unless marked with N/A).
3For UL-Marine and UL/CSA Type 4 listing add suffix “ML” to “EMI” Series fixture catalog number;
standard on “EMS” and “EMH” series. Not available on “EBF”, or “EQF” series.
EM/EB/EQ HAZARDOUS LOCATION DATA–CLASS II, III, DIVISIONS 1 & 2 1 2
EM/EB/EQ SERIES LIGHTING
PHOTOMETRIC DATA
L146
Illumination on Horizontal Surface
0
ANGLE CP ANGLE CP
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
72.
74.
86.
100.
109.
123.
148.
160.
155.
149.
146.
143.
130.
65.
9.
0.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.79
.68
.60
.53
.48
.44
.40
.36
.34
.31
.29
.79
.63
.52
.44
.38
.33
.29
.26
.23
.21
.19
.79
.58
.46
.37
.31
.26
.22
.19
.17
.15
.13
.74
.63
.56
.49
.45
.40
.37
.34
.31
.29
.27
.74
.59
.49
.41
.36
.31
.27
.24
.22
.20
.18
.74
.55
.43
.35
.29
.25
.21
.18
.16
.14
.12
.74
.51
.38
.30
.24
.20
.16
.13
.12
.10
.09
.79
.54
.40
.31
.25
.21
.17
.14
.12
.10
.09
.66
.52
.43
.36
.31
.27
.24
.21
.19
.17
.16
.66
.49
.38
.31
.26
.22
.18
.16
.14
.12
.11
.66
.46
.34
.26
.21
.17
.14
.12
.10
.09
.08
.59
.45
.37
.31
.27
.24
.21
.18
.17
.15
.14
.59
.43
.33
.27
.23
.19
.16
.14
.12
.11
.09
.59
.40
.30
.23
.19
.15
.13
.10
.09
.08
.07
.52
.40
.32
.27
.23
.20
.18
.16
.14
.13
.12
.52
.38
.29
.23
.20
.16
.14
.12
.10
.09
.08
.52
.36
.26
.20
.16
.13
.11
.09
.08
.06
.06
.49
.33
.23
.18
.14
.11
.09
.07
.06
.05
.04
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 2.4
Test No. LTL-00676
50
100
150
200
250
130
120
110
100
90
80
70
60
50
0 10 20 30 40
200
150
100
50
190 180 170 160 150 140
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
1.12
.72
.50
.36
.28
.22
1.02
.71
.51
.39
.30
.23
.55
.43
.36
.29
.25
.21
.39
.35
.30
.27
.21
.19
.23
.29
.25
.22
.19
.16
.22
.22
.21
.18
.16
.14
.16
.18
.17
.15
.14
.13
.12
.14
.14
.14
.12
.12
.07
.08
.09
.09
.09
.09
.04
.05
.05
.06
.06
.06
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.70
.64
.58
.52
.48
.43
.39
.36
.33
.31
.29
.70
.61
.53
.46
.40
.35
.31
.28
.25
.22
.20
.70
.58
.49
.41
.35
.30
.26
.22
.20
.17
.15
.68
.62
.56
.51
.46
.42
.38
.35
.32
.30
.28
.68
.59
.52
.45
.40
.35
.31
.27
.24
.22
.20
.68
.57
.48
.40
.35
.29
.25
.22
.19
.17
.15
.68
.55
.45
.37
.31
.26
.22
.18
.16
.14
.12
.70
.56
.45
.37
.31
.26
.22
.18
.16
.14
.12
.65
.57
.50
.43
.38
.33
.30
.26
.24
.21
.19
.65
.55
.46
.39
.34
.29
.25
.22
.19
.17
.15
.65
.53
.44
.36
.30
.25
.21
.18
.16
.14
.12
.62
.55
.48
.42
.37
.32
.29
.25
.23
.21
.19
.62
.53
.45
.38
.33
.28
.24
.21
.19
.17
.15
.62
.52
.43
.35
.30
.25
.21
.18
.16
.14
.12
.60
.53
.46
.40
.35
.31
.28
.24
.22
.20
.18
.60
.51
.44
.37
.32
.28
.24
.21
.18
.16
.15
.60
.50
.42
.35
.29
.25
.21
.18
.16
.14
.12
.58
.49
.41
.33
.28
.23
.20
.17
.14
.12
.11
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 1.4
Test No. LTL-00677
ANGLE CP ANGLE CP
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
261.
260.
254.
252.
236.
220.
221.
203.
72.
10.
2.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
50
100
150
200
250
120
110
100
90
80
70
60
50
40
0 10 20 30
150
100
50
180 170 160 150 140 130
Illumination on Horizontal Surface
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
4.07
2.61
1.81
1.33
1.01
.80
2.28
1.80
1.38
1.07
.86
.70
.83
.77
.71
.64
.57
.50
.58
.57
.54
.50
.46
.42
.40
.43
.42
.39
.37
.35
.28
.32
.33
.32
.30
.29
.21
.24
.26
.26
.25
.24
.13
.18
.20
.21
.21
.20
.04
.08
.11
.12
.13
.13
.02
.03
.05
.07
.08
.09
8
Illumination on Horizontal Surface
0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
209.
216.
241.
281.
291.
292.
304.
314.
296.
264.
238.
185.
63.
28.
7.
0.
0.
0.
0.
0.
0.
209.
213.
222.
227.
206.
190.
149.
55.
25.
6.
2.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.63
.56
.50
.45
.41
.38
.35
.32
.30
.27
.26
.63
.52
.45
.39
.34
.31
.27
.24
.22
.20
.18
.63
.49
.41
.34
.29
.25
.22
.19
.17
.15
.14
.61
.54
.48
.44
.40
.36
.33
.31
.29
.26
.25
.61
.51
.44
.38
.34
.30
.26
.24
.21
.19
.18
.61
.48
.40
.33
.29
.25
.22
.19
.17
.15
.14
.61
.46
.36
.30
.25
.21
.18
.16
.14
.12
.11
.63
.47
.37
.30
.26
.22
.19
.16
.14
.12
.11
.57
.48
.41
.36
.32
.28
.25
.22
.20
.19
.17
.57
.46
.38
.32
.28
.24
.21
.18
.16
.15
.13
.57
.44
.35
.29
.24
.21
.18
.15
.13
.12
.11
.54
.45
.39
.34
.30
.27
.24
.21
.19
.18
.16
.54
.43
.36
.30
.27
.23
.20
.18
.16
.14
.13
.54
.42
.34
.28
.24
.20
.17
.15
.13
.12
.10
.51
.42
.36
.32
.28
.25
.23
.20
.19
.17
.16
.51
.41
.34
.29
.25
.22
.19
.17
.15
.14
.12
.51
.40
.32
.27
.23
.20
.17
.15
.13
.11
.10
.50
.38
.31
.25
.22
.18
.16
.13
.12
.10
.09
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
0-DEG / 90-DEG
Spacing Criterion -- SC = 2.0 / 1.5
Test No. LTL-00678
50
100
150
200
250
120
110
100
90
80
70
60
50
0 10 20 30 40
200
150
100
50
180 170 160 150 140 130
A
FC = (Candlepower) (COS Ø)
DISTANCE2
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
3.26
2.09
1.45
1.06
.81
.64
2.74
2.01
1.46
1.09
.80
.66
1.13
1.03
.91
.80
.68
.58
.81
.78
.71
.64
.58
.51
.59
.59
.56
.52
.48
.44
.43
.45
.45
.43
.40
.37
.32
.35
.36
.35
.33
.31
.24
.27
.29
.29
.28
.27
.13
.15
.17
.18
.18
.18
.08
.09
.10
.12
.12
.12
8'
10'
12'
14'
16'
18'
3.26
2.09
1.45
1.06
.81
.64
2.09
1.62
1.23
.96
.76
.61
.64
.67
.62
.57
.52
.45
.37
.45
.44
.44
.41
.36
.19
.28
.33
.34
.33
.30
.10
.19
.24
.25
.26
.25
.05
.11
.17
.19
.20
.21
.03
.07
.09
.14
.16
.16
.02
.02
.03
.06
.08
.09
.01
.01
.02
.02
.04
.04
90˚
SIDE
FRONT
(FRONT)
ANGLE CP
90˚
(SIDE)
ANGLE CP
FOOTCANDLE CHART (Initial) 100 WATT INCANDESCENT FOOTCANDLE CHART (Initial) 100 WATT INCANDESCENT
FOOTCANDLE CHART (Initial) 100 WATT INCANDESCENT
EMI15 INCANDESCENT
With Globe Only
60 – 100 Watt Medium Base
CANDLEPOWER 100 WATT
A-19 lamp 1740 lumens
For 60 watt multiply by .494
For 75 watt multiply by .678
EMI15 INCANDESCENT
With Globe and Angle Reflector
60 – 100 Watt Medium Base
CANDLEPOWER – 100 WATT
A-19 lamp 1740 lumens
For 60 watt multiply by .494
For 75 watt multiply by .678
EMI15 INCANDESCENT
With Globe and Standard Dome Reflector
60 – 100 Watt Medium Base
CANDLEPOWER – 100 WATT
A-19 lamp 1740 lumens
For 60 watt multiply by .494
For 75 watt multiply by .678
EM/EB/EQ SERIES LIGHTING
PHOTOMETRIC DATA L147
L
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.87
.75
.67
.60
.55
.50
.45
.42
.38
.36
.33
.87
.70
.59
.50
.44
.39
.34
.30
.27
.25
.22
.87
.65
.52
.43
.36
.31
.26
.23
.20
.18
.16
.82
.70
.62
.56
.51
.46
.42
.38
.36
.33
.31
.82
.66
.55
.47
.41
.36
.32
.28
.26
.23
.21
.82
.61
.49
.40
.34
.29
.25
.22
.19
.17
.15
.82
.58
.44
.35
.29
.24
.20
.17
.15
.13
.11
.87
.61
.46
.37
.30
.25
.21
.18
.15
.13
.12
.72
.57
.48
.41
.36
.31
.28
.25
.22
.20
.18
.72
.54
.43
.35
.30
.26
.22
.19
.17
.15
.13
.72
.51
.39
.31
.25
.21
.18
.15
.13
.11
.10
.64
.50
.41
.35
.31
.27
.24
.21
.19
.17
.16
.64
.47
.37
.31
.26
.22
.19
.17
.15
.13
.12
.64
.45
.34
.27
.22
.18
.15
.13
.11
.10
.08
.56
.43
.35
.30
.26
.23
.20
.18
.16
.15
.14
.56
.41
.32
.26
.22
.19
.16
.14
.13
.11
.10
.56
.39
.29
.23
.19
.16
.13
.11
.10
.08
.07
.52
.35
.26
.20
.16
.13
.11
.09
.08
.07
.06
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 1.6
Test No. LTL-00679
ANGLE CP ANGLE CP
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
214.
215.
214.
213.
218.
230.
242.
249.
251.
246.
242.
235.
212.
171.
100.
27.
1.
0.
0.
0.
0.
50
100
150
200
250
120
110
100
90
80
70
60
50
0 10 20 30 40
150
100
50
180 170 160 150 140 130
Illumination on Horizontal Surface
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
3.34
2.14
1.48
1.09
.83
.66
2.05
1.65
1.17
.91
.73
.59
.90
.81
.70
.60
.51
.44
.65
.62
.56
.50
.44
.38
.47
.47
.45
.41
.37
.33
.34
.36
.36
.34
.32
.29
.26
.28
.29
.28
.27
.25
.20
.22
.23
.23
.23
.22
.11
.13
.14
.15
.15
.15
.07
.08
.09
.10
.10
.10
Illumination on Horizontal Surface
0
ANGLE CP ANGLE CP
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
571.
559.
505.
455.
431.
405.
372.
327.
206.
35.
4.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.79
.72
.65
.58
.53
.49
.45
.41
.38
.35
.32
.79
.68
.59
.51
.45
.40
.35
.31
.28
.26
.23
.79
.65
.54
.45
.39
.33
.29
.25
.22
.20
.18
.77
.70
.63
.57
.52
.47
.43
.40
.37
.34
.32
.77
.67
.58
.50
.44
.39
.35
.31
.28
.25
.23
.77
.64
.53
.45
.38
.33
.29
.25
.22
.20
.18
.77
.61
.49
.40
.34
.29
.24
.21
.18
.16
.14
.79
.62
.50
.41
.34
.29
.24
.21
.18
.16
.14
.74
.64
.55
.48
.42
.37
.33
.30
.27
.24
.22
.74
.62
.51
.43
.37
.32
.28
.24
.22
.19
.17
.74
.59
.48
.40
.34
.28
.24
.21
.18
.16
.14
.70
.61
.53
.46
.41
.36
.32
.29
.26
.24
.22
.70
.59
.50
.42
.37
.32
.27
.24
.21
.19
.17
.70
.58
.47
.39
.33
.28
.24
.20
.18
.16
.14
.67
.59
.51
.44
.39
.35
.31
.28
.25
.23
.21
.67
.57
.48
.41
.36
.31
.27
.23
.21
.19
.17
.67
.56
.46
.38
.33
.28
.24
.20
.18
.16
.14
.66
.54
.45
.37
.31
.26
.22
.19
.16
.14
.13
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 1.2
Test No. LTL-00680
100
200
300
400
500
600
120
110
100
90
80
70
60
50
40
0 10 20 30
200
100
180 170 160 150 140 130 0
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
8.92
5.71
3.96
2.91
2.23
1.76
4.17
3.17
2.57
2.05
1.68
1.39
1.47
1.43
1.32
1.18
1.04
.91
.98
1.02
.99
.93
.86
.76
.67
.72
.75
.73
.69
.65
.48
.51
.57
.57
.56
.54
.33
.40
.44
.46
.45
.44
.23
.30
.33
.36
.37
.36
.11
.14
.19
.21
.22
.23
.06
.08
.10
.13
.14
.15
F
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.70
.63
.56
.51
.47
.43
.40
.36
.34
.31
.29
.70
.59
.51
.44
.39
.35
.31
.28
.25
.23
.21
.70
.56
.46
.39
.34
.29
.26
.23
.20
.18
.16
.68
.60
.54
.49
.45
.41
.38
.35
.33
.30
.28
.68
.57
.49
.43
.38
.34
.30
.27
.25
.22
.20
.68
.54
.45
.38
.33
.29
.25
.22
.20
.18
.16
.68
.52
.41
.34
.29
.25
.21
.18
.16
.14
.13
.70
.53
.42
.35
.30
.25
.22
.19
.16
.14
.13
.64
.54
.46
.40
.36
.32
.29
.26
.23
.21
.20
.64
.51
.43
.36
.32
.28
.24
.21
.19
.17
.15
.64
.49
.40
.33
.28
.24
.21
.18
.16
.14
.12
.60
.50
.43
.38
.34
.30
.27
.24
.22
.20
.19
.60
.48
.41
.35
.30
.26
.23
.20
.18
.16
.15
.60
.47
.38
.32
.27
.23
.20
.17
.15
.14
.12
.57
.47
.41
.36
.32
.29
.26
.23
.21
.19
.18
.57
.46
.38
.33
.29
.25
.22
.20
.18
.16
.14
.57
.44
.36
.30
.26
.23
.20
.17
.15
.13
.12
.55
.43
.35
.29
.25
.21
.18
.16
.14
.12
.11
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
0-DEG / 90-DEG
Spacing Criterion -- SC = 1.8 / 1.4
Test No. LTL-00681
(FRONT)
ANGLE CP
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
435.
451.
486.
504.
520.
525.
518.
502.
479.
438.
401.
348.
204.
72.
14.
0.
0.
0.
0.
0.
0.
435.
437.
428.
416.
399.
372.
291.
157.
52.
10.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
150
250
350
450
550
120
110
100
90
80
70
60
50
40
0 10 20 30
350
250
150
180 170 160 150 140 130
F
Illumination on Horizontal Surface
FC = (Candlepower) (COS Ø)
DISTANCE2
90˚
(SIDE)
ANGLE CP
8
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
6.79
4.35
3.02
2.21
1.69
1.34
4.90
3.61
2.73
2.11
1.66
1.34
1.99
1.86
1.64
1.43
1.23
1.06
1.38
1.37
1.29
1.17
1.04
.92
.97
1.02
1.00
.95
.87
.79
.70
.77
.77
.76
.73
.67
.53
.58
.61
.62
.60
.57
.40
.45
.48
.50
.50
.48
.22
.25
.28
.30
.32
.28
.13
.15
.18
.19
.21
.21
8'
10'
12'
14'
16'
18'
6.79
4.35
3.02
2.22
1.70
1.34
3.86
2.98
2.29
1.80
1.45
1.18
1.26
1.32
1.21
1.10
.96
.84
.78
.87
.91
.86
.80
.70
.43
.57
.64
.67
.64
.60
.28
.39
.46
.51
.51
.50
.16
.26
.34
.41
.36
.41
.09
.16
.21
.28
.32
.29
.04
.06
.08
.13
.16
.18
.01
.03
.04
.06
.09
.09
90˚
SIDE
FRONT
FOOTCANDLE CHART (Initial) 150 WATT INCANDESCENT FOOTCANDLE CHART (Initial) 150 WATT INCANDESCENT FOOTCANDLE CHART (Initial) 150 WATT INCANDESCENT
EMI15 INCANDESCENT
With Globe Only
100 – 150 Watt Medium Base
CANDLEPOWER 150 WATT
A-21 lamp 2880 lumens
For 100 watt multiply by .587
EMI15 INCANDESCENT
With Globe and Angle Reflector
100 – 150 Watt Medium Base
CANDLEPOWER – 150 WATT
A-21 lamp 2880 lumens
For 100 watt multiply by .587
EMI15 INCANDESCENT
With Globe and Standard Dome Reflector
100 – 150 Watt Medium Base
CANDLEPOWER 150 WATT
A-21 lamp 2880 lumens
For 100 watt multiply by .587
EM/EB/EQ SERIES LIGHTING
PHOTOMETRIC DATA
L148
Illumination on Horizontal Surface
0
ANGLE CP ANGLE CP
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
127.
132.
177.
209.
235.
296.
370.
369.
351.
339.
332.
322.
241.
87.
11.
1.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.76
.65
.57
.51
.46
.41
.38
.34
.32
.29
.27
.76
.60
.50
.42
.36
.31
.27
.24
.22
.19
.18
.76
.55
.43
.35
.29
.24
.21
.18
.15
.13
.12
.72
.61
.53
.47
.43
.39
.35
.32
.30
.27
.25
.72
.57
.47
.39
.34
.30
.26
.23
.20
.18
.17
.72
.53
.41
.33
.28
.23
.20
.17
.15
.13
.11
.72
.49
.36
.28
.23
.18
.15
.12
.10
.09
.08
.76
.51
.38
.29
.24
.19
.16
.13
.11
.09
.08
.65
.50
.41
.35
.30
.26
.23
.20
.18
.16
.15
.65
.47
.37
.30
.25
.21
.17
.15
.13
.11
.10
.65
.44
.33
.25
.20
.16
.13
.11
.09
.08
.07
.58
.45
.36
.30
.26
.23
.20
.18
.16
.14
.13
.58
.42
.33
.26
.22
.18
.15
.13
.11
.10
.09
.58
.40
.29
.23
.18
.15
.12
.10
.08
.07
.06
.52
.39
.32
.26
.23
.20
.17
.15
.14
.12
.11
.52
.37
.29
.23
.19
.16
.13
.11
.10
.09
.08
.52
.35
.26
.20
.16
.13
.10
.08
.07
.06
.05
.49
.33
.23
.17
.14
.11
.08
.07
.05
.04
.04
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 3.0
Test No. LTL-00670
50
100
150
200
250
120
110
100
90
80
70
60
50
0 10 20 30 40
200
150
100
50
180 170 160 150 140 130
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
1.98
1.27
.88
.64
.49
.39
2.16
1.50
1.09
.82
.62
.49
1.30
1.05
.83
.65
.54
.46
.99
.87
.73
.59
.47
.40
.71
.73
.64
.53
.44
.37
.52
.55
.52
.46
.41
.34
.39
.42
.44
.41
.40
.32
.28
.33
.35
.36
.32
.29
.16
.19
.21
.22
.23
.23
.09
.11
.13
.14
.15
.16
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.66
.61
.55
.50
.46
.41
.38
.34
.32
.29
.27
.66
.58
.51
.44
.39
.34
.30
.26
.24
.21
.19
.66
.56
.47
.40
.34
.29
.25
.21
.19
.16
.15
.65
.59
.54
.49
.44
.40
.37
.33
.31
.28
.26
.65
.55
.46
.39
.33
.28
.24
.21
.18
.16
.14
.65
.53
.43
.36
.30
.25
.21
.17
.15
.13
.11
.66
.54
.44
.36
.30
.25
.21
.17
.15
.13
.11
.62
.55
.48
.42
.37
.32
.28
.25
.22
.20
.18
.62
.53
.45
.38
.33
.28
.24
.20
.18
.16
.14
.62
.51
.42
.35
.29
.24
.21
.17
.15
.13
.11
.59
.52
.46
.40
.35
.31
.27
.24
.22
.20
.18
.59
.51
.44
.37
.32
.27
.23
.20
.18
.16
.14
.59
.50
.41
.34
.29
.24
.20
.17
.15
.13
.11
.57
.50
.44
.39
.34
.30
.26
.23
.21
.19
.17
.57
.49
.42
.36
.31
.27
.23
.20
.17
.15
.14
.57
.48
.40
.34
.29
.24
.20
.17
.15
.13
.11
.56
.47
.39
.33
.27
.23
.19
.16
.14
.12
.10
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 1.5
Test No. LTL-00671
100
200
300
400
500
120
110
100
90
80
70
60
50
0 10 20 30 40
300
200
100
180 170 160 150 140 130
F
Illumination on Horizontal Surface
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
ANGLE CP ANGLE CP
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
517.
529.
534.
556.
519.
503.
531.
451.
108.
20.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
.65
.57
.50
.43
.38
.33
.29
.26
.23
.21
.19
88'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
8.08
5.17
3.59
2.64
2.02
1.60
5.06
3.98
3.00
2.32
1.83
1.47
1.97
1.78
1.61
1.43
1.26
1.11
1.42
1.36
1.24
1.14
1.04
.94
.94
1.04
.99
.91
.85
.78
.61
.77
.78
.74
.69
.66
.47
.56
.63
.62
.59
.55
.28
.42
.46
.51
.49
.47
.09
.18
.25
.29
.32
.33
.03
.09
.12
.17
.20
.21
Illumination on Horizontal Surface
0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
448.
473.
544.
590.
613.
641.
716.
700.
643.
563.
460.
316.
120.
58.
14.
0.
0.
0.
0.
0.
0.
448.
457.
486.
497.
460.
462.
353.
129.
59.
14.
5.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.60
.53
.48
.43
.40
.36
.33
.30
.28
.26
.24
.60
.50
.43
.37
.33
.29
.26
.23
.21
.19
.17
.60
.48
.39
.33
.28
.24
.21
.18
.16
.15
.13
.58
.51
.46
.42
.38
.35
.32
.29
.27
.25
.23
.58
.49
.42
.36
.32
.28
.25
.23
.20
.18
.17
.58
.46
.38
.32
.28
.24
.21
.18
.16
.14
.13
.58
.44
.35
.29
.24
.20
.17
.15
.13
.11
.10
.60
.45
.36
.29
.25
.21
.18
.15
.13
.12
.10
.55
.46
.40
.34
.31
.27
.24
.21
.19
.18
.16
.55
.44
.36
.31
.27
.23
.20
.17
.16
.14
.12
.55
.42
.34
.28
.24
.20
.17
.15
.13
.11
.10
.52
.43
.37
.33
.29
.26
.23
.20
.19
.17
.15
.52
.42
.35
.29
.26
.22
.19
.17
.15
.13
.12
.52
.40
.33
.27
.23
.19
.17
.14
.13
.11
.10
.49
.41
.35
.31
.27
.24
.22
.20
.18
.16
.15
.49
.40
.33
.28
.25
.21
.19
.16
.15
.13
.12
.49
.39
.31
.26
.22
.19
.16
.14
.12
.11
.10
.48
.37
.30
.25
.21
.18
.15
.13
.11
.10
.09
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
0-DEG / 90-DEG
Spacing Criterion -- SC = 2.0 / 1.6
Test No. LTL-00672
100
200
300
400
500
600
120
110
100
90
80
70
60
50
0 10 20 30 40
500
400
300
200
100
180 170 160 150 140 130
7
FC = (Candlepower) (COS Ø)
DISTANCE2
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
7.00
4.48
3.11
2.28
1.75
1.38
5.77
4.22
3.04
1.98
1.88
1.50
2.58
2.27
1.97
1.69
1.44
1.24
1.91
1.78
1.57
1.40
1.23
1.08
1.35
1.41
1.30
1.16
1.04
.94
.98
1.06
1.05
.97
.89
.81
.73
.81
.85
.82
.74
.70
.55
.63
.65
.69
.65
.61
.29
.34
.39
.42
.44
.44
.17
.21
.23
.27
.29
.30
8'
10'
12'
14'
16'
18'
7.00
4.48
3.11
2.28
1.75
1.38
4.50
3.56
2.69
2.09
1.67
1.26
1.55
1.63
1.45
1.26
1.12
.99
.94
1.07
1.13
1.03
.92
.83
.46
.69
.78
.83
.77
.70
.24
.46
.56
.63
.64
.59
.14
.27
.42
.44
.49
.50
.09
.15
.23
.34
.39
.40
.04
.06
.07
.14
.19
.22
.02
.03
.04
.05
.10
.10
90˚
(FRONT)
ANGLE CP
90˚
(SIDE)
ANGLE CP
SIDE
FRONT
FOOTCANDLE CHART (Initial) 200 WATT INCANDESCENT FOOTCANDLE CHART (Initial) 200 WATT INCANDESCENT FOOTCANDLE CHART (Initial) 200 WATT INCANDESCENT
EMI20 INCANDESCENT
With Globe Only
150 – 200 Watt Medium Base
CANDLEPOWER 200 WATT
A-23 lamp 4000 lumens
For 150 watt multiply by .695
EMI20 INCANDESCENT
With Globe and Angle Reflector
150 – 200 Watt Medium Base
CANDLEPOWER – 200 WATT
A-23 lamp 4000 lumens
For 150 watt multiply by .695
EMI20 INCANDESCENT
With Globe and Standard Dome Reflector
150 – 200 Watt Medium Base
CANDLEPOWER – 200 WATT
A-23 lamp 4000 lumens
For 150 watt multiply by .695
EM/EB/EQ SERIES LIGHTING
PHOTOMETRIC DATA L149
L
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.58
.50
.44
.40
.36
.32
.30
.27
.25
.23
.21
.58
.46
.39
.33
.28
.25
.22
.19
.17
.16
.14
.58
.43
.34
.28
.23
.19
.17
.14
.12
.11
.10
.55
.47
.41
.37
.33
.30
.27
.25
.23
.21
.20
.55
.41
.32
.26
.22
.18
.16
.13
.12
.10
.09
.55
.38
.28
.22
.18
.15
.12
.10
.09
.07
.06
.58
.40
.30
.23
.19
.16
.13
.11
.09
.08
.07
.49
.38
.31
.27
.23
.20
.18
.16
.14
.13
.11
.49
.36
.28
.23
.19
.16
.14
.12
.10
.09
.08
.49
.34
.25
.19
.16
.13
.11
.09
.08
.06
.06
.43
.33
.27
.23
.20
.17
.15
.13
.12
.11
.10
.43
.31
.24
.20
.16
.14
.12
.10
.09
.08
.07
.43
.29
.22
.17
.14
.11
.09
.08
.06
.06
.05
.38
.28
.23
.19
.17
.15
.13
.11
.10
.09
.08
.38
.27
.21
.17
.14
.12
.10
.08
.07
.07
.06
.38
.26
.19
.15
.12
.10
.08
.06
.05
.05
.04
.35
.23
.17
.13
.10
.08
.06
.05
.04
.03
.03
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 2.6
Test No. LTL-00673
75
125
200
275
325
400
120
110
100
90
80
70
60
50
0 10 20 30 40
200
125
75
180 170 160 150 140 130
Illumination on Horizontal Surface
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
165.
169.
206.
257.
298.
332.
380.
409.
405.
396.
388.
379.
348.
238.
66.
6.
0.
0.
0.
0.
0.
.55
.44
.36
.31
.27
.23
.20
.18
.16
.15
.13
ANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
2.58
1.65
1.15
.84
.64
.51
2.24
1.84
1.32
.98
.73
.57
1.36
1.17
.99
.82
.68
.57
1.01
.93
.82
.70
.60
.52
.75
.75
.68
.60
.52
.46
.56
.57
.56
.50
.46
.41
.43
.45
.45
.43
.40
.36
.33
.36
.37
.37
.34
.32
.18
.21
.23
.24
.24
.23
.11
.13
.14
.16
.16
.17
Illumination on Horizontal Surface
0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
725.
722.
675.
657.
646.
605.
580.
542.
255.
26.
2.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.52
.48
.43
.39
.35
.32
.29
.27
.25
.23
.21
.52
.45
.39
.34
.30
.26
.23
.20
.18
.17
.15
.52
.44
.36
.30
.26
.22
.19
.16
.14
.13
.11
.51
.46
.42
.38
.34
.31
.28
.26
.24
.22
.21
.51
.44
.38
.33
.29
.26
.23
.20
.18
.16
.15
.51
.43
.36
.30
.26
.22
.19
.16
.14
.13
.11
.51
.41
.33
.27
.23
.19
.16
.13
.12
.10
.09
.52
.42
.34
.27
.23
.19
.16
.13
.12
.10
.09
.49
.43
.37
.32
.28
.25
.22
.19
.18
.16
.14
.49
.41
.35
.29
.25
.21
.18
.16
.14
.12
.11
.49
.40
.32
.27
.22
.19
.16
.13
.12
.10
.09
.47
.41
.35
.31
.27
.24
.21
.19
.17
.15
.14
.47
.40
.33
.28
.24
.21
.18
.16
.14
.12
.11
.47
.39
.32
.26
.22
.18
.16
.13
.12
.10
.09
.45
.39
.34
.30
.26
.23
.20
.18
.16
.15
.14
.45
.38
.32
.27
.24
.20
.18
.15
.14
.12
.11
.45
.37
.31
.26
.22
.18
.15
.13
.11
.10
.09
.44
.37
.30
.25
.21
.17
.14
.12
.11
.09
.08
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 1.4
Test No. LTL-00674
100
200
300
400
500
600
700
110
90
80
70
60
50
40
0 10 20 30
100
180 160 140 130 120
5
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
ANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
11.32
7.25
5.03
3.70
2.83
2.24
6.23
4.70
3.60
2.83
2.26
1.86
2.16
2.14
1.97
1.78
1.55
1.34
1.55
1.49
1.48
1.40
1.29
1.15
1.07
1.14
1.09
1.09
1.04
.97
.78
.85
.88
.83
.84
.81
.57
.64
.69
.66
.65
.66
.36
.49
.53
.56
.54
.53
.15
.23
.31
.33
.35
.36
.07
.13
.16
.21
.23
.24
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.47
.41
.37
.34
.31
.28
.26
.24
.22
.20
.19
.47
.39
.33
.29
.26
.23
.20
.18
.16
.15
.13
.47
.37
.30
.25
.22
.19
.16
.14
.13
.11
.10
.45
.40
.36
.32
.30
.27
.25
.23
.21
.20
.18
.45
.36
.30
.25
.21
.19
.16
.14
.13
.11
.10
.45
.34
.27
.22
.19
.16
.14
.12
.10
.09
.08
.47
.35
.28
.23
.19
.16
.14
.12
.10
.09
.08
.43
.36
.31
.27
.24
.21
.19
.17
.15
.14
.13
.43
.34
.28
.24
.21
.18
.16
.14
.12
.11
.10
.43
.33
.26
.21
.18
.15
.13
.11
.10
.09
.08
.40
.34
.29
.25
.22
.20
.18
.16
.14
.13
.12
.40
.32
.27
.23
.20
.17
.15
.13
.12
.10
.09
.40
.31
.25
.21
.18
.15
.13
.11
.10
.08
.07
.38
.32
.27
.24
.21
.19
.17
.15
.14
.12
.11
.38
.31
.26
.22
.19
.16
.14
.13
.11
.10
.09
.38
.30
.24
.20
.17
.15
.13
.11
.09
.08
.07
.37
.29
.23
.19
.16
.14
.12
.10
.09
.07
.07
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
0-DEG / 90-DEG
Spacing Criterion -- SC = 2.1 / 1.6
Test No. LTL-00675
50
100
150
200
250
120
110
100
90
80
70
60
50
40
0 10 20 30
150
100
50
180 170 160 150 140 130
F
Illumination on Horizontal Surface
FC = (Candlepower) (COS Ø)
DISTANCE2
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
536.
558.
633.
750.
795.
797.
808.
813.
778.
696.
625.
501.
195.
68.
15.
0.
0.
0.
0.
0.
0.
536.
544.
572.
602.
585.
541.
432.
208.
73.
22.
10.
2.
0.
0.
0.
0.
0.
0.
0.
0.
0.
.45
.38
.32
.28
.25
.22
.20
.18
.16
.14
.13
A
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
8.38
5.36
3.72
2.73
2.09
1.65
7.44
5.37
3.90
2.94
2.27
1.75
3.05
2.82
2.51
2.19
1.86
1.59
2.15
2.10
1.96
1.78
1.59
1.40
1.55
1.59
1.54
1.44
1.33
1.21
1.13
1.20
1.21
1.17
1.10
1.03
.85
.93
.96
.95
.92
.87
.64
.73
.77
.78
.76
.74
.35
.41
.46
.48
.50
.50
.21
.25
.29
.31
.33
.34
8'
10'
12'
14'
16'
18'
8.38
5.36
3.72
2.73
2.09
1.65
5.63
4.31
3.24
2.50
1.96
1.58
1.86
1.91
1.77
1.61
1.41
1.22
1.15
1.28
1.33
1.26
1.17
1.05
.61
.85
.93
.98
.94
.87
.29
.54
.62
.74
.75
.72
.22
.37
.51
.55
.58
.59
.13
.19
.30
.42
.46
.47
.05
.09
.12
.19
.25
.27
.02
.04
.06
.08
.13
.13
90˚
(FRONT)
ANGLE CP
90˚
(SIDE)
ANGLE CP
SIDE
FRONT
FOOTCANDLE CHART (Initial) 300 WATT INCANDESCENT FOOTCANDLE CHART (Initial) 300 WATT INCANDESCENT FOOTCANDLE CHART (Initial) 300 WATT INCANDESCENT
EMI20 INCANDESCENT
With Globe Only Reflector
150, 200 and 300 Watt Medium Base
CANDLEPOWER 300 WATT
PS-25 lamp 6360 lumens
For 150 watt multiply by .421
For 200 watt multiply by .506
EMI20 INCANDESCENT
With Globe and Angle Reflector
150, 200 and 300 Watt Medium Base
CANDLEPOWER 300 WATT
PS-25 lamp 6360 lumens
For 150 watt multiply by .421
For 200 watt multiply by .506
EMI20 INCANDESCENT
With Globe and Standard Dome Reflector
150, 200 and 300 Watt Medium Base
CANDLEPOWER – 300 WATT
PS-25 lamp 6360 lumens
For 150 watt multiply by .421
For 200 watt multiply by .506
EM/EB/EQ SERIES LIGHTING
PHOTOMETRIC DATA
L150
Illumination on Horizontal Surface
0
.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
.135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0
139.
184.
213.
268.
364.
371.
381.
410.
402.
434.
488.
586.
573.
604.
585.
567.
566.
549.
515.
485.
389.
234.
80.
15.
11.
7.
3.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.72
.61
.54
.48
.43
.39
.35
.32
.30
.27
.25
.72
.57
.46
.39
.34
.29
.25
.23
.20
.18
.16
.72
.52
.40
.33
.27
.22
.19
.16
.14
.12
.11
.68
.58
.51
.45
.41
.36
.33
.30
.28
.26
.24
.68
.54
.44
.37
.32
.28
.24
.21
.19
.17
.16
.68
.50
.39
.31
.26
.21
.18
.16
.13
.12
.10
.68
.47
.34
.26
.21
.17
.14
.11
.10
.08
.07
.72
.49
.35
.28
.22
.17
.14
.12
.10
.08
.07
.63
.49
.40
.34
.29
.25
.22
.19
.17
.15
.14
.63
.46
.35
.29
.24
.19
.16
.14
.12
.11
.09
.63
.43
.31
.24
.19
.15
.13
.10
.09
.07
.06
.57
.44
.36
.30
.26
.22
.19
.17
.15
.14
.13
.57
.42
.32
.26
.21
.18
.15
.13
.11
.10
.08
.57
.39
.29
.22
.18
.14
.11
.09
.08
.07
.06
.52
.40
.32
.27
.23
.20
.17
.15
.14
.12
.11
.52
.38
.29
.23
.19
.16
.13
.11
.10
.08
.08
.52
.36
.26
.20
.16
.13
.10
.08
.07
.06
.05
.50
.33
.24
.18
.14
.11
.09
.07
.06
.04
.04
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 3.5
Test No. BALL-6769.1
100
200
300
400
500
120
110
100
90
80
70
60
50
0 10 20 30 40
400
300
200
100
180 170 160 150 140 130
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
ANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
2.17
1.39
.96
.71
.54
.43
3.67
2.65
1.97
1.55
1.01
.74
1.86
1.53
1.26
1.13
.92
.79
1.56
1.28
1.06
.90
.82
.67
1.09
1.15
.93
.78
.67
.62
.84
.85
.80
.69
.60
.52
.63
.66
.69
.66
.54
.47
.47
.54
.54
.56
.46
.43
.26
.30
.34
.34
.35
.36
.15
.19
.21
.23
.23
.24
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.61
.56
.51
.46
.42
.37
.34
.31
.28
.26
.24
.61
.53
.46
.41
.35
.30
.27
.24
.21
.19
.17
.61
.51
.43
.36
.31
.25
.22
.19
.16
.14
.13
.59
.54
.49
.45
.40
.36
.33
.30
.28
.25
.23
.59
.50
.42
.36
.30
.25
.22
.19
.16
.14
.12
.59
.49
.40
.33
.27
.22
.18
.15
.13
.11
.10
.61
.49
.40
.33
.27
.22
.18
.15
.13
.11
.10
.57
.50
.44
.38
.33
.29
.25
.22
.20
.18
.16
.57
.49
.41
.35
.30
.25
.21
.18
.16
.14
.12
.57
.47
.39
.32
.27
.21
.18
.15
.13
.11
.10
.54
.48
.42
.37
.32
.28
.24
.22
.19
.17
.16
.54
.47
.40
.34
.29
.24
.21
.18
.16
.13
.12
.54
.46
.38
.31
.26
.21
.18
.15
.13
.11
.09
.52
.46
.40
.35
.31
.27
.23
.21
.19
.17
.15
.52
.45
.39
.33
.28
.23
.20
.18
.15
.13
.12
.52
.44
.37
.31
.26
.21
.18
.15
.13
.11
.09
.51
.43
.36
.30
.25
.20
.17
.14
.12
.10
.08
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 1.7
Test No. BALL-6770.1
150
300
450
600
750
900
120
110
100
90
80
70
60
50
0 10 20 30 40
450
300
150
180 170 160 150 140 130
F
Illumination on Horizontal Surface
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0
649.
647.
684.
747.
825.
842.
768.
754.
738.
693.
705.
749.
774.
735.
458.
132.
82.
32.
3.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
1.
0.
1.
.59
.52
.46
.40
.35
.30
.26
.23
.21
.18
.17
AANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
10.14
6.49
4.51
3.31
2.53
2.00
7.26
6.02
4.57
3.51
2.63
2.06
2.68
2.45
2.32
2.07
1.81
1.58
2.00
1.85
1.70
1.65
1.51
1.36
1.48
1.47
1.35
1.25
1.23
1.14
1.06
1.13
1.03
1.02
.96
.95
.77
.89
.89
.86
.80
.76
.42
.67
.73
.72
.67
.64
.16
.27
.41
.46
.47
.46
.03
.14
.18
.28
.32
.32
Illumination on Horizontal Surface
0
%Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.52
.46
.41
.37
.34
.31
.28
.26
.24
.22
.20
.52
.43
.37
.32
.28
.24
.22
.19
.17
.16
.14
.52
.41
.33
.28
.23
.20
.17
.15
.13
.12
.10
.51
.45
.40
.36
.32
.29
.27
.25
.23
.21
.20
.51
.42
.36
.31
.27
.24
.21
.19
.17
.15
.14
.51
.40
.32
.27
.23
.19
.17
.15
.13
.11
.10
.51
.38
.29
.24
.20
.16
.14
.12
.10
.09
.08
.52
.39
.30
.24
.20
.16
.14
.12
.10
.09
.08
.48
.40
.33
.29
.25
.22
.20
.18
.16
.14
.13
.48
.38
.31
.26
.22
.19
.16
.14
.12
.11
.10
.48
.36
.28
.23
.19
.16
.13
.12
.10
.09
.08
.45
.37
.31
.27
.24
.21
.19
.17
.15
.14
.12
.45
.36
.29
.25
.21
.18
.15
.14
.12
.11
.09
.45
.34
.27
.22
.19
.15
.13
.11
.10
.08
.07
.42
.35
.30
.26
.23
.20
.18
.16
.14
.13
.12
.42
.34
.28
.23
.20
.17
.15
.13
.11
.10
.09
.42
.33
.26
.21
.18
.15
.13
.11
.09
.08
.07
.41
.32
.25
.20
.17
.14
.12
.10
.08
.07
.06
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
0-DEG / 90-DEG
Spacing Criterion -- SC =2.14 / 1.5
Test No. BALL-6771.1
200
400
600
800
1000
1200
120
110
100
90
80
70
60
50
0 10 20 30 40
800
600
400
200
180 170 160 150 140 130
FC = (Candlepower) (COS Ø)
DISTANCE2
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
8.80
5.63
3.91
2.87
2.20
1.74
8.18
6.63
5.01
3.90
3.03
2.45
3.43
3.09
2.77
2.34
2.04
1.77
2.53
2.37
2.15
1.96
1.71
1.52
1.87
1.86
1.73
1.58
1.46
1.30
1.39
1.42
1.41
1.44
1.21
1.13
1.04
1.12
1.13
1.08
1.03
.95
.79
.89
.93
.91
.86
.83
.43
.50
.56
.58
.58
.58
.24
.31
.35
.38
.40
.41
8'
10'
12'
14'
16'
18'
8.80
5.63
3.91
2.87
2.20
1.74
5.18
4.16
3.30
2.56
2.06
1.68
2.17
1.90
1.73
1.53
1.29
1.11
1.58
1.49
1.32
1.23
1.12
.99
.59
1.16
1.09
.97
.91
.84
.25
.80
.88
.82
.74
.71
.16
.36
.70
.68
.64
.59
.09
.16
.29
.57
.54
.52
.04
.04
.08
.18
.36
.36
.02
.03
.03
.06
.13
.13
90˚
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
563.
714.
888.
927.
853.
875.
950.
998.
890.
807.
561.
179.
96.
33.
0.
0.
0.
0.
0.
0.
0.
563.
499.
608.
582.
558.
538.
592.
150.
68.
15.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
(FRONT)
ANGLE CP
90˚
(SIDE)
ANGLE CP
SIDE
FRONT
FOOTCANDLE CHART (Initial) 300 WATT INCANDESCENT FOOTCANDLE CHART (Initial) 300 WATT INCANDESCENT FOOTCANDLE CHART (Initial) 300 WATT INCANDESCENT
EMI30 INCANDESCENT
With Globe Only
200 – 300 Watt Medium Base
CANDLEPOWER 300 WATT
PS-25 lamp 6360 lumens
For 200 watt multiply by .597
EMI30 INCANDESCENT
With Globe and Angle Reflector
200 – 300 Watt Medium Base
CANDLEPOWER – 300 WATT
PS-25 lamp 6360 lumens
For 200 watt multiply by .597
EMI30 INCANDESCENT
With Globe and Standard Dome Reflector
200 – 300 Watt Medium Base
CANDLEPOWER – 300 WATT
PS-25 lamp 6360 lumens
For 200 watt multiply by .597
EM/EB/EQ SERIES LIGHTING
PHOTOMETRIC DATA L151
L
Illumination on Horizontal Surface
0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
13.
14.
21.
31.
48.
60.
66.
66.
63.
57.
52.
48.
37.
24.
13.
2.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.60
.52
.45
.40
.37
.33
.30
.27
.25
.23
.21
.60
.48
.40
.33
.29
.25
.22
.19
.17
.15
.14
.60
.44
.35
.28
.23
.19
.16
.14
.12
.10
.09
.57
.49
.43
.38
.34
.31
.28
.25
.23
.22
.20
.57
.45
.37
.31
.27
.23
.20
.18
.16
.14
.13
.57
.42
.33
.26
.22
.18
.15
.13
.11
.10
.09
.57
.39
.29
.22
.18
.14
.12
.10
.08
.07
.06
.60
.41
.31
.24
.19
.15
.12
.10
.08
.07
.06
.51
.40
.33
.28
.24
.21
.18
.16
.14
.13
.11
.51
.38
.29
.24
.20
.16
.14
.12
.10
.09
.08
.51
.35
.26
.20
.16
.13
.10
.08
.07
.06
.05
.46
.36
.29
.24
.21
.18
.16
.14
.12
.11
.10
.46
.34
.26
.21
.17
.14
.12
.10
.09
.08
.07
.46
.32
.24
.18
.14
.11
.09
.07
.06
.05
.04
.41
.31
.25
.21
.18
.16
.13
.12
.11
.09
.08
.41
.30
.23
.18
.15
.12
.10
.09
.08
.06
.06
.41
.28
.21
.16
.13
.10
.08
.06
.05
.04
.04
.39
.26
.19
.14
.11
.08
.06
.05
.04
.03
.02
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 3.8
Test No. LTL 00667
10
20
30
40
50
60
120
110
100
90
80
70
60
50
0 10 20 30 40
50
40
30
20
10
180 170 160 150 140 130
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
ANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
.20
.13
.09
.07
.05
.04
.40
.22
.15
.11
.08
.06
.24
.21
.17
.13
.10
.08
.18
.16
.15
.12
.10
.07
.12
.13
.12
.11
.09
.07
.09
.10
.10
.09
.08
.07
.07
.07
.07
.07
.07
.06
.05
.06
.06
.06
.06
.06
.03
.03
.04
.04
.04
.04
.02
.02
.02
.02
.03
.03
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.52
.48
.43
.39
.35
.32
.29
.27
.25
.23
.21
.52
.45
.39
.34
.30
.26
.23
.20
.18
.16
.15
.52
.43
.36
.30
.26
.22
.19
.16
.14
.12
.11
.51
.46
.42
.38
.34
.31
.28
.26
.24
.22
.20
.51
.43
.36
.30
.26
.22
.19
.16
.14
.12
.11
.51
.41
.33
.27
.23
.19
.16
.13
.11
.10
.08
.52
.42
.33
.27
.23
.19
.16
.13
.11
.10
.08
.49
.42
.37
.32
.28
.25
.22
.19
.17
.15
.14
.49
.41
.34
.29
.25
.21
.18
.16
.14
.12
.11
.49
.40
.32
.26
.22
.19
.16
.13
.11
.10
.08
.47
.41
.35
.31
.27
.24
.21
.19
.17
.15
.13
.47
.39
.33
.28
.24
.21
.18
.15
.13
.12
.10
.47
.38
.32
.26
.22
.18
.15
.13
.11
.10
.08
.45
.39
.34
.30
.26
.23
.20
.18
.16
.14
.13
.45
.38
.32
.27
.24
.20
.18
.15
.13
.12
.10
.45
.37
.31
.26
.22
.18
.15
.13
.11
.09
.08
.44
.36
.30
.25
.21
.17
.14
.12
.10
.09
.07
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 1.6
Test No. LTL 00668
15
30
45
60
75
90
110
100
90
80
70
60
50
40
0 10 20 30
30
15
180 160 150 130 120
Illumination on Horizontal Surface
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
92.
93.
86.
86.
95.
97.
88.
64.
35.
7.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
.51
.44
.38
.33
.29
.26
.23
.20
.18
.16
.14
ANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
1.44
.92
.64
.47
.36
.28
.88
.61
.47
.37
.29
.24
.35
.34
.30
.26
.22
.18
.22
.24
.24
.21
.19
.16
.14
.17
.18
.17
.16
.14
.10
.12
.14
.14
.13
.12
.07
.07
.10
.11
.11
.10
.05
.06
.07
.08
.09
.09
.02
.03
.04
.04
.05
.05
.00
.01
.02
.02
.03
.03
Test No. LTL 00669
8
Illumination on Horizontal Surface
0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
36.
27.
35.
53.
81.
106.
121.
126.
123.
113.
106.
97.
77.
54.
32.
12.
1.
0.
0.
0.
0.
36.
37.
46.
58.
70.
81.
81.
68.
60.
52.
46.
41.
30.
19.
8.
0.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.50
.44
.39
.35
.31
.28
.26
.24
.22
.20
.19
.50
.41
.34
.29
.25
.22
.19
.17
.15
.14
.13
.50
.38
.30
.25
.21
.18
.15
.13
.11
.10
.09
.48
.41
.37
.33
.30
.27
.24
.22
.21
.19
.18
.48
.39
.32
.28
.24
.21
.18
.16
.15
.13
.12
.48
.36
.29
.24
.20
.17
.14
.12
.11
.10
.08
.48
.34
.26
.20
.17
.14
.11
.10
.08
.07
.06
.50
.36
.27
.21
.17
.14
.12
.10
.08
.07
.06
.44
.35
.29
.25
.22
.19
.17
.15
.13
.12
.11
.44
.33
.26
.22
.18
.15
.13
.11
.10
.09
.08
.44
.31
.24
.19
.15
.13
.11
.09
.08
.06
.06
.40
.32
.26
.22
.19
.17
.15
.13
.12
.11
.10
.40
.30
.24
.20
.17
.14
.12
.10
.09
.08
.07
.40
.29
.22
.17
.14
.12
.10
.08
.07
.06
.05
.36
.28
.23
.20
.17
.15
.13
.12
.11
.10
.09
.36
.27
.22
.18
.15
.13
.11
.09
.08
.07
.06
.36
.26
.20
.16
.13
.11
.09
.07
.06
.05
.05
.35
.24
.18
.14
.12
.09
.08
.06
.05
.04
.04
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
0-DEG / 90-DEG
Spacing Criterion -- SC = 3.2 / 2.7
0
25
50
75
100
120
110
100
90
80
70
60
50
0 10 20 30 40
75
50
25
0
180 170 160 150 140 130
FC = (Candlepower) (COS Ø)
DISTANCE2
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
.56
.36
.25
.18
.14
.11
.69
.38
.26
.19
.13
.10
.43
.37
.29
.22
.17
.14
.32
.30
.26
.21
.16
.13
.24
.24
.22
.19
.15
.13
.17
.18
.18
.16
.15
.12
.13
.14
.14
.14
.13
.11
.10
.11
.12
.12
.11
.10
.05
.06
.07
.07
.07
.07
.03
.04
.04
.05
.05
.04
8'
10'
12'
14'
16'
18'
.56
.36
.25
.18
.14
.11
.63
.41
.29
.22
.17
.13
.31
.29
.24
.19
.16
.13
.22
.21
.20
.17
.14
.12
.14
.16
.15
.15
.12
.11
.10
.12
.12
.12
.11
.10
.07
.08
.10
.09
.09
.09
.05
.06
.07
.08
.08
.07
.03
.03
.04
.04
.05
.05
.02
.02
.02
.03
.03
.03
90˚
(FRONT)
ANGLE CP
90˚
(SIDE)
ANGLE CP
SIDE
FRONT
FOOTCANDLE CHART (Initial) (1) 13 WATT FLUORESCENT FOOTCANDLE CHART (Initial) (1) 13 WATT FLUORESCENT FOOTCANDLE CHART (Initial) (1) 13 WATT FLUORESCENT
EBF13/EQF SERIES FLUORESCENT
With Globe Only
One 13 Watt Bi-Pin Base
or one 26/32/42 Quad-Pin
CANDLEPOWER – (1) 13 WATT
PL lamp 900 lumens
For 26 watt quad-pin
multiply by 2.0
For 32 watt quad-pin
multiply by 2.66
For 42 watt quad-pin
multiply by 3.55
EBF13/EQF SERIES FLUORESCENT
With Globe and Angle Reflector
One 13 Watt Bi-Pin Base
or one 26/32/42 Quad-Pin
CANDLEPOWER – (1) 13 WATT
PL lamp 900 lumens
For 26 watt quad-pin
multiply by 2.0
For 32 watt quad-pin
multiply by 2.66
For 42 watt quad-pin
multiply by 3.55
EBF13/EQF SERIES FLUORESCENT
With Globe and Standard Dome Reflector
One 13 Watt Bi-Pin Base
or one 26/32/42 Quad-Pin
CANDLEPOWER – (1) 13 WATT
PL lamp 900 lumens
For 26 watt quad-pin
multiply by 2.0
For 32 watt quad-pin
multiply by 2.66
For 42 watt quad-pin
multiply by 3.55
EM/EB/EQ SERIES LIGHTING
PHOTOMETRIC DATA
L152
Test No. LTL 00682
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.52
.44
.39
.35
.31
.28
.26
.23
.22
.20
.18
.52
.41
.34
.29
.25
.22
.19
.17
.15
.13
.12
.52
.38
.30
.24
.20
.17
.14
.12
.10
.09
.08
.49
.42
.37
.32
.29
.26
.24
.22
.20
.19
.17
.49
.36
.28
.23
.19
.16
.13
.11
.10
.09
.08
.49
.34
.25
.19
.16
.13
.10
.08
.07
.06
.05
.52
.36
.26
.20
.16
.13
.11
.09
.07
.06
.05
.44
.34
.28
.24
.21
.18
.16
.14
.12
.11
.10
.44
.32
.25
.20
.17
.14
.12
.10
.09
.08
.07
.44
.30
.23
.17
.14
.11
.09
.07
.06
.05
.04
.39
.30
.25
.21
.18
.16
.14
.12
.11
.10
.09
.39
.29
.22
.18
.15
.12
.10
.09
.08
.07
.06
.39
.27
.20
.15
.13
.10
.08
.07
.05
.05
.04
.35
.27
.22
.18
.16
.13
.12
.10
.09
.08
.07
.35
.25
.20
.16
.13
.11
.09
.08
.07
.06
.05
.35
.24
.18
.14
.11
.09
.07
.06
.05
.04
.03
.33
.22
.16
.12
.09
.07
.06
.04
.04
.03
.02
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 3.5
0
25
50
75
100
120
110
100
90
80
70
60
50
0 10 20 30 40
50
25
0
180 170 160 150 140 130
Illumination on Horizontal Surface
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
28.
29.
40.
58.
82.
100.
110.
111.
106.
96.
90.
82.
63.
44.
24.
7.
1.
0.
0.
0.
0.
.49
.39
.32
.27
.23
.20
.18
.16
.14
.12
.11
ANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
.44
.28
.19
.14
.11
.09
.71
.41
.28
.21
.15
.11
.40
.35
.29
.22
.17
.14
.29
.27
.24
.20
.16
.13
.21
.22
.20
.18
.15
.13
.15
.16
.16
.15
.14
.12
.12
.13
.13
.13
.12
.11
.09
.10
.10
.10
.10
.09
.05
.06
.06
.06
.07
.07
.03
.03
.04
.04
.04
.05
Test No. LTL 00683
Illumination on Horizontal Surface
0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
189.
193.
191.
190.
204.
205.
188.
136.
74.
15.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.56
.51
.46
.42
.38
.35
.31
.29
.26
.24
.22
.56
.49
.42
.36
.32
.28
.25
.22
.20
.17
.16
.56
.46
.39
.32
.28
.24
.20
.17
.15
.13
.12
.55
.50
.45
.40
.37
.33
.30
.28
.26
.24
.22
.55
.47
.41
.36
.31
.28
.24
.21
.19
.17
.16
.55
.46
.38
.32
.27
.23
.20
.17
.15
.13
.12
.55
.44
.36
.29
.24
.20
.17
.14
.12
.11
.09
.56
.45
.36
.39
.35
.20
.17
.14
.12
.11
.09
.52
.45
.39
.34
.30
.27
.23
.21
.19
.17
.15
.52
.44
.37
.31
.27
.23
.20
.17
.15
.13
.11
.52
.42
.35
.28
.24
.20
.17
.14
.12
.10
.09
.50
.44
.38
.33
.29
.26
.23
.20
.18
.16
.15
.50
.42
.36
.30
.26
.22
.19
.17
.15
.13
.11
.50
.41
.34
.28
.24
.20
.17
.14
.12
.10
.09
.48
.42
.36
.32
.28
.25
.22
.19
.17
.16
.14
.48
.41
.35
.29
.25
.22
.19
.16
.14
.13
.11
.48
.40
.33
.27
.23
.20
.17
.14
.12
.10
.09
.47
.39
.32
.26
.22
.19
.16
.13
.11
.09
.08
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 1.6
25
50
75
100
125
150
175
200
110
100
90
80
70
50
40
0 10 20 30
50
25
180 160 140 130 120
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
ANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
2.95
1.89
1.31
.96
.73
.58
1.85
1.36
1.04
.81
.65
.53
.75
.72
.64
.56
.46
.41
.50
.52
.50
.45
.41
.34
.31
.37
.38
.37
.34
.31
.21
.28
.29
.29
.28
.26
.14
.18
.22
.23
.23
.22
.09
.13
.15
.18
.19
.18
.04
.06
.08
.10
.12
.11
.02
.03
.04
.05
.06
.07
Test No. LTL 00684
I
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.49
.44
.40
.36
.33
.30
.27
.25
.23
.21
.20
.49
.41
.36
.31
.27
.24
.21
.19
.17
.15
.14
.49
.39
.32
.27
.23
.20
.17
.15
.13
.12
.10
.48
.42
.38
.34
.31
.29
.26
.24
.22
.21
.19
.48
.38
.32
.27
.23
.20
.17
.15
.13
.12
.10
.48
.36
.29
.24
.20
.17
.14
.12
.11
.09
.08
.49
.37
.30
.24
.20
.17
.15
.12
.11
.09
.08
.45
.38
.32
.28
.25
.22
.20
.18
.16
.14
.13
.45
.36
.30
.25
.22
.19
.16
.14
.13
.11
.10
.45
.35
.28
.23
.19
.16
.14
.12
.10
.09
.08
.42
.36
.31
.27
.24
.21
.19
.17
.15
.14
.12
.42
.34
.29
.24
.21
.18
.16
.14
.12
.11
.10
.42
.33
.27
.22
.19
.16
.14
.12
.10
.09
.08
.40
.33
.29
.25
.22
.20
.18
.16
.14
.13
.12
.40
.32
.27
.23
.20
.17
.15
.13
.12
.10
.09
.40
.31
.26
.21
.18
.15
.13
.11
.10
.09
.07
.39
.30
.25
.20
.17
.14
.12
.10
.09
.08
.07
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
0-DEG / 90-DEG
Spacing Criterion -- SC = 2.3 / 1.8
50
100
150
200
250
120
110
100
90
80
70
60
50
40
0 10 20 30
150
100
50
180 170 160 150 140 130
Illumination on Horizontal Surface
FC = (Candlepower) (COS Ø)
DISTANCE2
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
155.
166.
190.
211.
242.
264.
274.
269.
238.
189.
161.
132.
75.
27.
4.
0.
0.
0.
0.
0.
0.
155.
155.
160.
171.
188.
174.
130.
78.
35.
10.
4.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
.48
.40
.35
.30
.27
.23
.21
.19
.17
.15
.14
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
2.42
1.55
1.08
.79
.60
.48
3.53
1.51
1.11
.85
.66
.30
1.02
.93
.80
.66
.55
.46
.73
.70
.65
.56
.48
.34
.52
.54
.51
.48
.42
.37
.38
.41
.41
.39
.36
.33
.28
.28
.32
.32
.30
.29
.21
.24
.26
.26
.26
.25
.11
.13
.15
.16
.17
.17
.06
.08
.09
.10
.11
.11
8'
10'
12'
14'
16'
18'
2.42
1.55
1.08
.79
.60
.48
1.73
1.22
.91
.70
.55
.44
.58
.61
.57
.52
.43
.37
.35
.40
.43
.40
.38
.32
.20
.25
.29
.31
.30
.29
.13
.18
.21
.23
.24
.23
.08
.12
.15
.17
.18
.19
.05
.05
.10
.12
.14
.15
.02
.03
.04
.06
.07
.08
.00
.02
.02
.03
.04
.04
90˚
(FRONT)
ANGLE CP
90˚
(SIDE)
ANGLE CP
SIDE
FRONT
FOOTCANDLE CHART (Initial) (2) 13 WATT FLUORESCENT FOOTCANDLE CHART (Initial) (2) 13 WATT FLUORESCENT
FOOTCANDLE CHART (Initial) (2) 13 WATT FLUORESCENT
EBF26 FLUORESCENT
With Globe Only
Two 13 Watt Bi-Pin Base
CANDLEPOWER – (2) 13 WATT
PL lamps
900 lumens per lamp
EBF26 FLUORESCENT
With Globe and Angle Reflector
Two 13 Watt Bi-Pin Base
CANDLEPOWER – (2) 13 WATT
PL lamps
900 lumens per lamp
EBF26 FLUORESCENT
With Globe and Standard Dome Reflector
Two 13 Watt Bi-Pin Base
CANDLEPOWER – (2) 13 WATT
PL lamps
900 lumens per lamp
EM/EB/EQ SERIES LIGHTING
PHOTOMETRIC DATA L153
L
Illumination on Horizontal Surface
0
.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0
80.
84.
108.
148.
202.
262.
298.
321.
352.
397.
444.
467.
471.
540.
562.
603.
618.
633.
644.
651.
635.
624.
581.
505.
250.
23.
8.
3.
3.
1.
0.
0.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.85
.72
.64
.57
.51
.46
.42
.39
.36
.33
.31
.85
.67
.55
.47
.41
.35
.31
.27
.25
.22
.20
.85
.62
.48
.39
.33
.27
.23
.20
.18
.15
.14
.79
.67
.58
.52
.47
.42
.39
.36
.33
.30
.28
.79
.62
.51
.43
.37
.32
.28
.25
.23
.20
.19
.79
.58
.45
.36
.30
.25
.21
.19
.16
.14
.13
.79
.54
.39
.31
.25
.20
.16
.14
.12
.10
.09
.85
.57
.42
.33
.27
.21
.18
.15
.13
.11
.10
.69
.53
.43
.37
.32
.27
.24
.21
.19
.17
.16
.69
.50
.38
.31
.26
.21
.18
.16
.14
.12
.11
.69
.46
.34
.26
.21
.17
.14
.12
.10
.08
.07
.60
.45
.36
.30
.26
.22
.20
.18
.16
.14
.13
.60
.42
.32
.26
.21
.18
.15
.13
.11
.10
.09
.60
.40
.29
.22
.18
.14
.11
.09
.08
.07
.06
.51
.37
.30
.25
.21
.18
.16
.14
.13
.11
.10
.51
.35
.26
.21
.17
.14
.12
.10
.09
.08
.07
.51
.33
.24
.18
.14
.11
.09
.07
.06
.05
.04
.47
.29
.20
.15
.11
.08
.07
.05
.04
.03
.03
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 4.3
Test No. BALL 6686.0
100
200
300
400
500
600
120
110
100
90
80
70
60
50
0 10 20 30 40
500
400
300
200
100
180 170 160 150 140 130
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
ANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
1.25
.80
.55
.41
.31
.25
2.94
1.87
1.21
.86
.57
.41
1.69
1.40
1.11
.88
.74
.61
1.24
1.16
.97
.77
.64
.55
.90
.92
.85
.71
.59
.50
.73
.70
.69
.62
.55
.45
.56
.54
.55
.54
.48
.43
.43
.47
.44
.45
.42
.39
.25
.28
.30
.28
.29
.29
.16
.18
.19
.21
.19
.20
Illumination on Horizontal Surface
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.66
.58
.52
.47
.42
.38
.35
.32
.30
.27
.25
.66
.54
.46
.39
.34
.30
.27
.24
.21
.19
.17
.66
.51
.41
.34
.29
.24
.21
.18
.16
.14
.12
.64
.55
.49
.44
.40
.36
.33
.31
.28
.26
.24
.64
.52
.44
.38
.33
.29
.26
.23
.20
.18
.17
.64
.49
.39
.33
.28
.23
.20
.18
.16
.14
.12
.64
.46
.35
.29
.24
.19
.16
.14
.12
.10
.09
.66
.48
.36
.29
.24
.20
.17
.14
.12
.11
.09
.59
.48
.40
.35
.31
.27
.24
.21
.19
.17
.16
.59
.46
.37
.31
.26
.22
.19
.17
.15
.13
.11
.59
.43
.33
.27
.22
.18
.16
.13
.12
.10
.09
.55
.44
.37
.32
.28
.25
.22
.20
.18
.16
.14
.55
.42
.34
.29
.24
.21
.18
.16
.14
.12
.11
.55
.40
.31
.26
.21
.18
.15
.13
.11
.09
.08
.51
.41
.34
.30
.26
.23
.20
.18
.16
.15
.13
.51
.39
.32
.27
.23
.19
.17
.15
.13
.11
.10
.51
.38
.30
.24
.20
.17
.14
.12
.10
.09
.08
.50
.36
.28
.22
.19
.15
.13
.11
.09
.08
.07
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
0-DEG / 90-DEG
Spacing Criterion -- SC = 2.53 / 1.87
Test No. BALL 6688.0
150
300
450
600
750
120
110
100
90
80
70
60
50
0 10 20 30 40
600
450
300
150
180 170 160 150 140 130
FC = (Candlepower) (COS Ø)
DISTANCE2
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
7.33
4.69
3.26
2.39
1.83
1.45
9.07
6.05
4.11
3.11
2.31
1.81
3.67
3.44
3.04
2.57
2.27
1.97
2.69
2.53
2.39
2.16
1.87
1.69
1.89
1.98
1.85
1.76
1.61
1.43
1.39
1.50
1.46
1.40
1.34
1.25
1.04
1.13
1.20
1.15
1.10
1.03
.79
.89
.94
.97
.92
.89
.44
.51
.56
.59
.65
.62
.26
.31
.35
.38
.40
.42
8'
10'
12'
14'
16'
18'
7.33
4.69
3.26
2.39
1.83
1.45
6.88
5.27
3.59
2.72
1.91
1.50
2.45
2.39
2.06
1.96
1.74
1.52
1.64
1.69
1.66
1.46
1.43
1.30
1.12
1.20
1.23
1.22
1.09
1.06
.81
.90
.93
.95
.93
.84
.60
.67
.73
.75
.74
.74
.34
.52
.55
.59
.61
.59
.15
.17
.32
.35
.37
.38
.02
.12
.13
.22
.24
.25
90˚
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
469.
520.
655.
846.
937.
974.
1011.
993.
994.
955.
915.
786.
120.
39.
0.
0.
0.
0.
0.
0.
0.
469.
479.
543.
736.
713.
677.
614.
578.
84.
21.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
(FRONT)
ANGLE CP
90˚
(SIDE)
ANGLE CP
SIDE
FRONT
FOOTCANDLE CHART (Initial) 70 WATT H.P.S. FOOTCANDLE CHART (Initial) 70 WATT H.P.S.
EMS HIGH PRESSURE SODIUM
With Globe Only
35 – 100 Watt Medium Base
CANDLEPOWER – 70 WATT
B-17 clear lamp 6300 lumens
For 35 watt multiply by .357
For 50 watt multiply by .635
For 100 watt multiply by 1.508
EMS HIGH PRESSURE SODIUM
With Globe and Angle Reflector
35 – 100 Watt Medium Base
CANDLEPOWER – 70 WATT
B-17 clear lamp 6300 lumens
For 35 watt multiply by .357
For 50 watt multiply by .635
For 100 watt multiply by 1.508
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.76
.69
.61
.55
.50
.45
.41
.38
.34
.32
.29
.76
.65
.55
.47
.41
.36
.31
.28
.25
.22
.20
.76
.62
.50
.41
.35
.29
.25
.22
.19
.16
.15
.74
.67
.59
.53
.48
.43
.40
.36
.33
.31
.29
.74
.61
.49
.41
.34
.29
.25
.22
.19
.16
.15
.74
.59
.45
.36
.30
.24
.20
.17
.15
.13
.11
.76
.60
.46
.37
.30
.24
.20
.17
.15
.13
.11
.71
.61
.52
.44
.39
.33
.30
.26
.24
.21
.19
.71
.59
.48
.40
.33
.28
.24
.21
.18
.16
.14
.71
.57
.44
.36
.29
.24
.20
.17
.15
.12
.11
.68
.59
.49
.42
.37
.32
.28
.25
.23
.20
.18
.68
.57
.46
.38
.33
.27
.24
.21
.18
.16
.14
.68
.55
.43
.35
.29
.24
.20
.17
.14
.12
.11
.65
.56
.47
.41
.36
.31
.27
.24
.22
.20
.18
.65
.55
.45
.37
.32
.27
.23
.20
.18
.15
.14
.65
.53
.42
.34
.28
.23
.20
.17
.14
.12
.11
.64
.52
.41
.33
.27
.22
.18
.15
.13
.11
.10
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 1.3
Test No. BALL 6687.0
150
300
450
600
750
900
1150
110
100
90
80
70
60
50
40
0 10 20 30
300
150
180 160 140 130 120
Illumination on Horizontal Surface
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0
960.
933.
957.
902.
856.
808.
805.
789.
786.
812.
804.
766.
722.
740.
724.
689.
170.
31.
3.
1.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
.74
.64
.54
.46
.40
.35
.31
.27
.24
.22
.20
ANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
15.00
9.60
6.67
4.89
3.75
2.96
7.63
5.78
4.54
3.65
2.97
2.49
3.06
2.87
2.47
2.17
2.14
1.66
2.04
2.11
1.99
1.75
1.58
1.41
1.38
1.50
1.54
1.46
1.31
1.19
1.02
1.11
1.18
1.18
1.12
1.01
.77
.83
.91
.92
.92
.89
.58
.65
.68
.74
.76
.75
.31
.38
.42
.43
.45
.47
.18
.23
.26
.28
.29
.30
F
FOOTCANDLE CHART (Initial) 70 WATT H.P.S.
EMS HIGH PRESSURE SODIUM
With Globe and Standard Dome Reflector
35 – 100 Watt Medium Base
CANDLEPOWER – 70 WATT
B-17 clear lamp 6300 lumens
For 35 watt multiply by .357
For 50 watt multiply by .635
For 100 watt multiply by 1.508
EM/EB/EQ SERIES LIGHTING
PHOTOMETRIC DATA
L154
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.82
.70
.61
.55
.49
.45
.41
.37
.34
.32
.30
.82
.64
.53
.45
.39
.34
.30
.26
.24
.21
.19
.82
.60
.46
.38
.31
.26
.22
.19
.17
.15
.13
.76
.65
.56
.50
.45
.41
.37
.34
.32
.29
.27
.76
.56
.43
.35
.29
.24
.21
.18
.16
.14
.12
.76
.52
.38
.29
.24
.19
.16
.13
.11
.10
.08
.82
.55
.40
.32
.25
.20
.17
.14
.12
.10
.09
.66
.51
.42
.35
.30
.26
.23
.21
.18
.17
.15
.66
.48
.37
.30
.25
.20
.17
.15
.13
.12
.10
.66
.45
.32
.25
.20
.16
.13
.11
.09
.08
.07
.57
.43
.35
.29
.25
.22
.19
.17
.15
.14
.12
.57
.41
.31
.25
.21
.17
.14
.12
.11
.09
.08
.57
.38
.27
.21
.17
.13
.11
.09
.08
.06
.05
.49
.36
.28
.24
.20
.17
.15
.13
.12
.11
.10
.49
.34
.25
.20
.17
.13
.11
.10
.08
.07
.06
.49
.32
.22
.17
.14
.10
.08
.07
.06
.05
.04
.45
.28
.19
.14
.11
.08
.06
.05
.04
.03
.02
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 4.3
Test No. BALL 6683.0
250
500
750
1000
1250
1500
1750
120
110
100
90
80
70
60
50
0 10 20 30 40
1000
750
500
250
180 170 160 150 140 130
Illumination on Horizontal Surface
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0
195.
212.
267.
362.
480.
611.
701.
763.
864.
960.
1048.
1117.
1264.
1304.
1374.
1505.
1555.
1568.
1546.
1576.
1596.
1514.
1386.
1150.
685.
245.
25.
10.
3.
2.
0.
0.
0.
0.
0.
0.
0.
.76
.60
.49
.42
.36
.31
.27
.24
.22
.20
.18
ANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
3.05
1.95
1.35
.99
.76
.60
7.35
4.37
2.76
2.04
1.31
1.00
3.99
3.39
2.72
2.10
1.70
1.44
2.98
2.75
2.36
1.93
1.53
1.27
2.41
2.19
2.01
1.73
1.44
1.19
1.78
1.71
1.65
1.50
1.32
1.11
1.36
1.45
1.32
1.25
1.18
1.05
1.09
1.14
1.19
1.07
1.00
.95
.62
.67
.73
.75
.70
.69
.40
.43
.48
.50
.51
.53
Illumination on Horizontal Surface
0
.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0
2289.
2296.
2282.
2117.
1981.
1921.
1911.
1888.
1898.
1940.
1959.
1898.
1869.
1851.
1763.
1469.
601.
93.
7.
3.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.71
.65
.58
.52
.47
.42
.38
.35
.32
.30
.28
.71
.61
.52
.45
.39
.34
.30
.26
.23
.21
.19
.71
.59
.47
.39
.33
.27
.24
.20
.18
.15
.14
.70
.63
.56
.50
.45
.41
.37
.34
.31
.29
.27
.70
.60
.51
.44
.38
.33
.29
.26
.23
.20
.19
.70
.57
.47
.39
.32
.27
.23
.20
.18
.15
.14
.70
.55
.43
.34
.28
.23
.19
.16
.14
.12
.10
.71
.56
.43
.35
.28
.23
.19
.16
.14
.12
.10
.67
.57
.49
.42
.36
.31
.28
.25
.22
.20
.18
.67
.55
.45
.37
.32
.26
.23
.20
.17
.15
.13
.67
.53
.42
.34
.28
.23
.19
.16
.14
.12
.10
.64
.55
.47
.40
.35
.30
.27
.24
.21
.19
.17
.64
.53
.44
.36
.31
.26
.22
.19
.17
.15
.13
.64
.52
.41
.33
.27
.22
.19
.16
.14
.12
.10
.61
.53
.45
.39
.34
.29
.26
.23
.21
.18
.17
.61
.52
.42
.35
.30
.25
.22
.19
.17
.14
.13
.61
.50
.40
.33
.27
.22
.19
.16
.14
.11
.10
.60
.49
.39
.31
.26
.21
.17
.15
.12
.10
.09
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 1.3
Test No. BALL 6684.0
300
600
900
1200
1500
1800
2100
2400
100
90
80
70
60
50
40
0 10 20 30
300
180 160 140 120
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
ANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
35.76
22.89
15.89
11.68
8.94
7.06
18.03
13.74
10.75
8.44
7.10
5.84
7.46
6.86
5.97
5.19
4.54
3.94
5.06
5.14
4.76
4.24
3.78
3.36
3.57
3.73
3.75
3.50
3.16
2.88
2.57
2.82
2.87
2.85
2.68
2.44
1.94
2.14
2.25
2.33
2.24
2.12
1.42
1.66
1.77
1.83
1.86
1.81
.75
.91
1.04
1.11
1.16
1.17
.39
.56
.63
.71
.76
.78
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.64
.56
.50
.45
.41
.37
.34
.31
.29
.26
.25
.64
.52
.44
.38
.33
.29
.26
.23
.21
.18
.17
.64
.49
.39
.33
.28
.23
.20
.18
.15
.13
.12
.62
.54
.47
.43
.39
.35
.32
.30
.27
.25
.23
.62
.47
.38
.32
.27
.23
.20
.17
.15
.13
.12
.62
.44
.34
.28
.23
.19
.16
.14
.12
.10
.09
.64
.46
.35
.28
.23
.19
.16
.14
.12
.10
.09
.57
.46
.39
.34
.29
.26
.23
.20
.18
.16
.15
.57
.44
.35
.29
.25
.21
.18
.16
.14
.12
.11
.57
.42
.32
.26
.22
.18
.15
.13
.11
.09
.08
.53
.43
.36
.31
.27
.24
.21
.19
.17
.15
.14
.53
.41
.33
.28
.23
.20
.17
.15
.13
.12
.10
.53
.39
.30
.25
.20
.17
.14
.12
.10
.09
.08
.50
.40
.33
.29
.25
.22
.20
.18
.16
.14
.13
.50
.38
.31
.26
.22
.19
.16
.14
.12
.11
.10
.50
.36
.28
.23
.19
.16
.14
.12
.10
.08
.07
.48
.35
.27
.21
.18
.14
.12
.10
.09
.07
.06
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
0-DEG / 90-DEG
Spacing Criterion -- SC = 2.53 / 1.87
Test No. BALL 6685.0
500
1000
1500
2000
2500
120
110
100
90
80
70
60
50
0 10 20 30 40
1500
1000
500
180 170 160 150 140 130
Illumination on Horizontal Surface
FC = (Candlepower) (COS Ø)
DISTANCE2
.62
.50
.42
.37
.32
.28
.25
.22
.20
.18
.16
I
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
18.17
11.63
8.08
5.93
4.54
3.59
21.86
15.18
10.34
7.82
5.63
4.39
9.74
8.76
7.24
6.34
5.46
4.72
6.62
6.71
6.08
5.13
4.62
4.08
4.80
4.87
4.90
4.47
3.85
3.49
3.50
3.70
3.74
3.71
3.42
2.96
2.62
2.88
2.94
3.00
2.89
2.70
1.96
2.24
2.38
2.39
2.43
2.35
1.08
1.26
1.41
1.50
1.52
1.53
.68
.78
.88
.97
1.02
1.06
8'
10'
12'
14'
16'
18'
18.17
11.63
8.08
5.93
4.54
3.59
16.06
11.99
8.62
6.63
4.63
3.63
5.59
5.38
4.76
4.49
4.02
3.50
3.92
3.85
3.74
3.37
3.27
2.93
2.78
2.88
2.81
2.75
2.51
2.44
1.91
2.18
2.20
2.15
2.10
1.95
1.40
1.67
1.74
1.73
1.67
1.66
.74
1.22
1.38
1.41
1.40
1.37
.31
.47
.75
.86
.90
.90
.07
.26
.33
.52
.59
.61
90˚
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
1163.
1259.
1590.
2122.
2308.
2478.
2481.
2506.
2540.
2431.
2307.
1868.
584.
104.
3.
2.
0.
0.
0.
0.
0.
1163.
1170.
1315.
1676.
1635.
1523.
1469.
1341.
256.
32.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
(FRONT)
ANGLE CP
90˚ (SIDE)
ANGLE CP
SIDE
FRONT
FOOTCANDLE CHART (Initial) 150 WATT H.P.S. FOOTCANDLE CHART (Initial) 150 WATT H.P.S. FOOTCANDLE CHART (Initial) 150 WATT H.P.S.
EMS HIGH PRESSURE SODIUM
With Globe Only Reflector
150 Watt Medium Base
CANDLEPOWER – 150 WATT
B-17 clear lamp
16000 lumens
EMS HIGH PRESSURE SODIUM
With Globe and Angle Reflector
150 Watt Medium Base
CANDLEPOWER – 150 WATT
B-17 clear lamp
16000 lumens
EMS HIGH PRESSURE SODIUM
With Globe and Standard Dome Reflector
150 Watt Medium Base
CANDLEPOWER – 150 WATT
B-17 clear lamp
16000 lumens
EM/EB/EQ SERIES LIGHTING
PHOTOMETRIC DATA L155
L
Illumination on Horizontal Surface
0
.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
55.0
50.0
65.0
60.0
75.0
70.0
80.0
85.0
90.0
95.0
100.0
105.0
110.0
115.0
120.0
125.0
130.0
135.0
140.0
145.0
150.0
155.0
160.0
165.0
170.0
175.0
180.0
173.
206.
188.
225.
290.
361.
403.
452.
492.
552.
610.
618.
658.
731.
796.
776.
787.
863.
874.
847.
846.
832.
750.
641.
440.
88.
14.
5.
2.
1.
0.
0.
0.
0.
0.
0.
0.
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.84
.72
.63
.57
.51
.46
.42
.39
.36
.33
.31
.84
.67
.55
.47
.41
.35
.31
.28
.25
.22
.20
.84
.62
.48
.39
.33
.27
.23
.20
.18
.16
.14
.79
.67
.58
.52
.47
.42
.39
.36
.33
.30
.28
.79
.62
.51
.43
.38
.32
.29
.25
.23
.21
.19
.79
.58
.45
.36
.30
.25
.22
.19
.16
.14
.13
.79
.53
.39
.31
.25
.20
.17
.14
.12
.10
.09
.84
.57
.42
.33
.27
.22
.18
.15
.13
.11
.10
.69
.53
.43
.37
.32
.27
.24
.21
.19
.17
.16
.69
.50
.38
.31
.26
.22
.18
.16
.14
.12
.11
.69
.46
.34
.27
.21
.17
.14
.12
.10
.09
.07
.60
.45
.36
.31
.26
.23
.20
.18
.16
.14
.13
.60
.42
.32
.26
.22
.18
.15
.13
.11
.10
.09
.60
.40
.29
.22
.18
.14
.12
.10
.08
.07
.06
.51
.38
.30
.25
.21
.18
.16
.14
.13
.11
.10
.51
.35
.27
.21
.18
.14
.12
.11
.09
.08
.07
.51
.33
.24
.18
.15
.11
.09
.08
.06
.05
.04
.47
.30
.20
.15
.12
.09
.07
.05
.04
.03
.03
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
Spacing Criterion -- SC = 3.4
Test No. BALL 6689.0
150
300
450
600
750
120
110
100
90
80
70
60
50
0 10 20 30 40
600
450
300
150
180 170 160 150 140 130
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
FC = (Candlepower) (COS Ø)
DISTANCE2
ANGLE CP ANGLE CP
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
2.70
1.73
1.20
.88
.67
.53
3.93
2.58
1.66
1.23
.80
.62
2.32
1.95
1.55
1.24
.98
.83
1.65
1.60
1.35
1.10
.90
.73
1.25
1.21
1.17
.99
.82
.70
1.00
.93
.92
.87
.76
.63
.76
.75
.73
.72
.68
.60
.59
.64
.62
.59
.58
.55
.35
.38
.41
.39
.38
.38
.21
.25
.26
.28
.27
.27
Illumination on Horizontal Surface
0
% Effective
Ceiling Cavity
Reflectance 1cc
% Wall
Reflectance 1w
Room Cavity
Ratio RCR
.61
.54
.48
.43
.39
.36
.33
.30
.28
.25
.24
.61
.50
.42
.37
.32
.28
.25
.22
.20
.18
.16
.61
.47
.38
.32
.27
.23
.20
.17
.15
.13
.12
.59
.51
.46
.41
.37
.34
.31
.28
.26
.24
.23
.59
.48
.41
.35
.31
.27
.24
.21
.19
.17
.16
.59
.46
.37
.31
.26
.22
.19
.17
.15
.13
.11
.59
.43
.33
.27
.22
.18
.15
.13
.11
.10
.08
.61
.44
.34
.27
.23
.19
.16
.14
.12
.10
.09
.55
.45
.38
.33
.29
.25
.22
.20
.18
.16
.15
.55
.42
.34
.29
.24
.21
.18
.16
.14
.12
.11
.55
.40
.31
.25
.21
.17
.15
.13
.11
.09
.08
.51
.41
.35
.30
.26
.23
.21
.18
.17
.15
.14
.51
.40
.32
.27
.23
.19
.17
.15
.13
.11
.10
.51
.38
.29
.24
.20
.16
.14
.12
.10
.09
.08
.48
.38
.32
.28
.24
.21
.19
.17
.15
.14
.13
.48
.37
.30
.25
.21
.18
.16
.14
.12
.11
.10
.48
.35
.28
.23
.19
.16
.13
.11
.10
.08
.07
.46
.34
.26
.21
.17
.14
.12
.10
.09
.07
.06
0
1
2
3
4
5
6
7
8
9
10
20% Effective Floor Cavity Reflectance
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10
80 70 50 30 10 0
Coefficients of Utilization -- Zonal Cavity Method
0-DEG / 90-DEG
Spacing Criterion -- SC = 2.25 / 1.58
Test No. BALL 6703.0
150
300
450
600
750
1000
120
110
100
90
80
70
60
50
0 10 20 30 40
450
300
150
180 160 150 140 130
FC = (Candlepower) (COS Ø)
DISTANCE2
FOOTCANDLE CHART (Inital) 100 WATT H.P.S
Horizontal Distance From Source in Feet
Mounting Height in Feet
8'
10'
12'
14'
16'
18'
0' 5' 10' 12' 14' 16' 18' 20' 25' 30'
11.58
7.41
5.14
3.78
2.89
2.29
11.82
7.86
5.61
4.31
3.21
2.56
4.86
4.38
3.81
3.43
2.96
2.55
3.48
3.35
3.04
2.70
2.50
2.22
2.39
2.56
2.44
2.23
2.02
1.88
1.75
1.93
1.95
1.85
1.71
1.56
1.32
1.43
1.55
1.52
1.45
1.35
1.01
1.12
1.18
1.26
1.22
1.17
.55
.64
.71
.74
.80
.80
.32
.40
.45
.48
.51
.52
8'
10'
12'
14'
16'
18'
11.58
7.41
5.14
3.78
2.89
2.29
7.52
6.40
4.54
3.47
2.57
2.05
2.73
2.74
2.38
2.13
1.88
1.62
2.04
1.88
1.90
1.69
1.55
1.40
1.32
1.50
1.37
1.40
1.26
1.17
.62
1.12
1.13
1.03
1.07
.97
.47
.79
.90
.86
.84
.85
.16
.40
.65
.73
.68
.67
.04
.11
.25
.41
.46
.47
.02
.04
.07
.17
.28
.29
90˚
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
.0
5.0
15.0
25.0
35.0
45.0
55.0
65.0
75.0
85.0
90.0
95.0
105.0
115.0
125.0
135.0
145.0
155.0
165.0
175.0
180.0
741.
775.
928.
1099.
1249.
1239.
1305.
1258.
1218.
1262.
1119.
938.
163.
54.
0.
0.
0.
0.
0.
0.
0.
741.
692.
744.
895.
776.
776.
764.
454.
70.
2.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
5
(FRONT)
ANGLE CP
90˚ (SIDE)
ANGLE CP
SIDE
FRONT
FOOTCANDLE CHART (Initial) 100 WATT METAL HALIDE
FOOTCANDLE CHART (Initial) 100 WATT METAL HALIDE
EMH (MH)
With Globe Only
50 – 100 Watt Medium Base
CANDLEPOWER – 100 WATT MH
B-17 clear lamp 8500 lumens
For 70 watt M.H. multiply by .647
For 50 watt M.H. multiply by .447
EMH (MH)
With Globe and Angle Reflector
50 – 100 Watt Medium Base
CANDLEPOWER – 100 WATT MH
B-17 clear lamp 8500 lumens
For 70 watt M.H. multiply by .647
For 50 watt M.H. multiply by .447
Test No. BAL 6702
Test No. BAL 6689.0
EMH (MH)
With Globe and Standard Dome
Reflector 50 – 100 Watt Medium Base
CANDLEPOWER – 100 WATT MH
B-17 clear lamp 8500 lumens
For 70 watt M.H. multiply by .647
For 50 watt M.H. multiply by .447
Efficiency 60.6%
694
1041
1388
90˚
80˚
70˚
60˚
50˚
40˚30˚20˚10˚
180˚ 160˚ 150˚ 140˚ 130˚ 120˚
110˚
100˚
347
% EFFECTIVE
CEILING CAVITY
REFLECTANCE
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .72 .72 .72 .72 .70 .70.70 .70 .67 .67 .67 .64.64 .64 .62 .62 .62 .61
1 .65 .61 .58 .55 .63 .60.57 .54 .57 .55 .53 .55.53 .51 .52 .51 .49 .48
2 .58 .52 .47 .43 .56 .50.46 .42 .48 .44 .41 .46.43 .40 .44 .41 .39 .38
3 .52 .44 .38 .34 .50 .43.38 .33 .41 .37 .33 .39.36 .32 .38 .34 .32 .30
4 .47 .38 .32 .28 .45 .37.32 .27 .36 .31 .27 .34.30 .27 .33 .29 .26 .25
5 .42 .34 .28 .23 .41 .33.27 .23 .32 .27 .23 .30.26 .22 .29 .25 .22 .21
6 .39 .30 .24 .20 .38 .29.24 .20 .28 .23 .19 .27.23 .19 .26 .22 .19 .18
7 .36 .27 .21 .17 .35 .26.21 .17 .25 .20 .17 .25.20 .17 .24 .20 .17 .15
8 .33 .24 .19 .15 .32 .24.19 .15 .23 .18 .15 .22.18 .15 .22 .18 .15 .13
9 .31 .22 .17 .13 .30 .22.17 .13 .21 .17 .13 .21.16 .13 .20 .16 .13 .12
10 .29 .21 .15 .12 .28 .20.15 .12 .20 .15 .12 .19.15 .12 .18 .15 .12 .11
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
SPACING TO MOUNTING HEIGHT RATIO - 1.12
ANGLE CP ANGLE CP
01388. 95.0 2.
5.0 1323. 100.0 1.
10.0 1257. 105.0 0.
15.0 1225. 110.0 0.
20.0 1102. 115.0 0.
25.0 1032. 120.0 0.
30.0 1033. 125.0 0.
35.0 1037. 130.0 0.
40.0 1048. 135.0 0.
45.0 1075. 140.0 0.
50.0 1073. 145.0 0.
55.0 1006. 150.0 0.
60.0 982. 155.0 0.
65.0 999. 160.0 0.
70.0 992. 165.0 0.
75.0 792. 170.0 0.
80.0 210. 175.0 0.
85.0 48. 180.0 0.
90.0 7.
EZ SERIES LIGHTING
MOGUL BASE HID FIXTURES
L156
FEATURES-SPECIFICATIONS
Applications
HOSTILELITE®EZ Series mogul base
fixtures are designed for installations
where moisture, dirt, dust, corrosion
and vibration may be present, or NEMA
3 and 4x areas where wind, water,
snow or high ambients can be ex-
pected. They can be used in locations
made hazardous due to the presence
of flammable or explosive gases,
vapors and combustible dusts as
defined by the NEC.
Typical applications include classified
areas such as paint manufacturing
plants, ammunition facilities, oil and
gas producing and refining plants,
off-shore and dockside installations,
tank farms, pipeline pumping stations
and marine loading and fuel transfer
terminals.
Features
Three light sources—High Pressure
Sodium (50-400W), Metal Halide
(70-400W) and Pulse Start Metal
Halide (175-400W)
HOSTILELITE®EZ fixtures are now
available with Pulse Start Metal
Halide ballasts
Mounting choice—Pendant, ceiling,
25˚ stanchion or 90˚ wall mount, all
with “wireless” design that allows fast,
easy fixture installation or removal for
maintenance. See pages L196-197 for
trunnion mounted fixtures
Factory sealed—No external seal
needed. Simply wire mounting cap
and thread on fixture to install
Corrosion resistant—Copper-free alu-
minum die cast construction. Baked
powder epoxy finish, electrostatically
applied. Exposed hardware is 316
grade stainless steel
Accessories—Available with or with-
out guard, standard dome or angle
reflector
Options—EZ Series fixtures can be
specified with instant restart for HPS
lamps, auxiliary quartz circuit, ballast
Catalog Number Logic
Series Constant
Lamp Type
S—High Pressure Sodium
H—Metal Halide
P—Pulse Start Metal Halide
Lamp Wattage
05—50 Watt HPS
07—70 Watt HPS/MH
10—100 Watt HPS/MH
15—150 Watt HPS/MHP
17—175 Watt MH/MHP2
20—200 Watt HPS/MHP
25—250 Watt HPS/MH/MHP2
32—320 Watt MHP
35—350 Watt MHP
40—400 Watt HPS/MH/MHP2
Voltage
0—Quadri-Volt, 60 Hz. (120, 208, 240, 277)
5—480 Volts, 60 Hz.
6—TriTap Canada (120, 277, 347), 60 Hz.
7—220V, 60Hz
8—220/240 Volt, 50 Hz.
9—Special (Specify)
Options
Q—Auxiliary Quartz
Standby
R—Instant Restrike
(150W HPS Max)
BP—Ballast Protector
PS—Paint Spray
(50, 70, 100W HPS,
100W MV, 70, 100, MH)
EB—Eyebolts1
SU103—Assembled w/Lamp
Guard
G—Omit G if guard
is not required
Mounting Type
A2—3/4" Pendant
A3—1" Pendant
X2—3/4" Ceiling
X3—1" Ceiling
B2—3/4" Bracket
B3—1" Bracket
D4—1-1/4"/1-1/2" Stanchion
EZ 0 00 0 00 0 - 00 (CEN*)
protector, and fuse kits.
(See page L160 for details)
Compliances
UL-844 Electric Lighting Fixtures for
use in Hazardous Locations
UL Marine Type Electric Lighting
Fixtures
UL-1598 Standard for HID Lighting
Fixtures
CSA C22.2 no. 137-M1981 Electric
Luminaires for use in Hazardous
Locations
CSA C22.2 no. 94-1976 Special
purpose enclosure
NEMA 3, 4, 4x, 7CD, 9EFG
*CEN (CENELEC) Approved option available on some models. See page L164 for more information.
1Two eyebolts plus 12" of connecting chain included. 2175,250 and 400W MH EXPORT ONLY (EISA LAW).
Consult factory for available lamp and voltage combinations.
HOSTILELITE®EZ fixtures are now
available with Pulse Start Metal Halide
ballasts. Pulse Start systems provide
higher and better maintained light out-
put with longer life compared standard
metal halide systems. Pulse start and
standard Metal Halide lamps and
ballasts are not interchangeable.
V
V
Listed - File E10514 and E91793
Certified - File LR11713
Class I, Div. 1 & 2 Groups C,D
Class l, Zone 1 & 2, Groups llB,llA
Class l, Zone 1, AEx d IIB
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
Suitable for wet locations
Marine
NEMA 3, 4, 4X
Factory Sealed
EZ SERIES LIGHTING
HIGH PRESSURE SODIUM 50-400W MOGUL BASE HID L157
L
120, 208, 240, 277 EZS050A2G EZS050X2G EZS050B2G EZS050D4G
50 120, 277, 347 ——
480 ——
120, 208, 240, 277 EZS070A2G EZS070X2G EZS070B2G EZS070D4G
70 120, 277, 347 EZS076A2G EZS076X2G EZS076B2G EZS076D4G
480 EZS075A2G EZS075X2G EZS075B2G EZS075D4G
120, 208, 240, 277 EZS100A2G EZS100X2G EZS100B2G EZS100D4G
100 120, 277, 347 EZS106A2G EZS106X2G EZS106B2G EZS106D4G
480 EZS105A2G EZS105X2G EZS105B2G EZS105D4G
120, 208, 240, 277 EZS150A2G EZS150X2G EZS150B2G EZS150D4G
150 120, 277, 347 EZS156A2G EZS156X2G EZS156B2G EZS156D4G
480 EZS155A2G EZS155X2G EZS155B2G EZS155D4G
120, 208, 240, 277 EZS250A2G EZS250X2G EZS250B2G EZS250D4G
250 120, 277, 347 EZS256A2G EZS256X2G EZS256B2G EZS256D4G
480 EZS255A2G EZS255X2G EZS255B2G EZS255D4G
120, 208, 240, 277 EZS400A2G EZS400X2G EZS400B2G EZS400D4G
400 120, 277, 347 EZS406A2G EZS406X2G EZS406B2G EZS406D4G
480 EZS405A2G EZS405X2G EZS405B2G EZS405D4G
ANSI
LAMP
S-68
S-62
S-54
S-55
S-50
S-51
EZ 50-400 WATT, HIGH PRESSURE SODIUM 1 4
CATALOG NUMBER
PENDANT 3/4"2CEILING 3/4"2WALL 3/4"2STANCHION 1-1/4"3
WATTS VOLTAGE @ 60Hz
1See Hazardous Location Application Data on pages L164-165 for specific suitabilities.
2For 1 inch pendant, ceiling and wall hubs, substitute “3” for “2” in catalog number; example: EZS070A3G.
3Stanchion conduit hub size supplied is 1-1/2" with 1-1/2" to 1-1/4" reducer for 1-1/4" mounting. (Refer to catalog logic).
4Luminaire catalog numbers include guards. To order luminaire without guard, omit last letter “G” from catalog number.
NOTE: Reflectors must be ordered separately (see page L161).
All luminaires are designed for mounting with lamp in base up position.
Pendant Ceiling Wall Stanchion
Listed - File E10514 and E91793 (Marine)
Certified - File LR11713
Class I, Div. 1 & 2 Groups C,D
Class l, Zone 1 & 2, Groups llB,llA
Class l, Zone 1, AEx d IIB
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
Suitable for wet locations
Marine
NEMA 3, 4, 4X
Factory Sealed
FEATURES-SPECIFICATIONS
EZ SERIES LIGHTING
METAL HALIDE 70-400W MOGUL BASE HID
158
ORDERING INFORMATION
Listed - File E10514 and E91793 (Marine)
Certified - File LR11713
Class I, Div. 1 & 2 Groups C,D
Class l, Zone 1 & 2, Groups llB,llA
Class l, Zone 1, AEx d IIB
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
Suitable for wet locations
Marine
NEMA 3, 4, 4X
Factory Sealed
120, 208, 240, 277 EZH070A2G EZH070X2G EZH070B2G EZH070D4G
70 120, 277, 3 4 7 EZH076A2G EZH076X2G EZH076B2G EZH076D4G
480 EZH075A2G EZH075X2G EZH075B2G EZH075D4G
120, 208, 240, 277 EZH100A2G EZH100X2G EZH100B2G EZH100D4G
100 120, 277,347 EZH106A2G EZH106X2G EZH106B2G EZH106D4G
480 EZH105A2G EZH105X2G EZH105B2G EZH105D4G
120, 208, 240, 277 EZH170A2G EZH170X2G EZH170B2G EZH170D4G
175 120, 277,347 EZH176A2G EZH176X2G EZH176B2G EZH176D4G
480 EZH175A2G EZH175X2G EZH175B2G EZH175D4G
120, 208, 240, 277 EZH250A2G EZH250X2G EZH250B2G EZH250D4G
250 120, 277,347 EZH256A2G EZH256X2G EZH256B2G EZH256D4G
480 EZH255A2G EZH255X2G EZH255B2G EZH255D4G
120, 208, 240, 277 EZH400A2G EZH400X2G EZH400B2G EZH400D4G
400 120, 277,347 EZH406A2G EZH406X2G EZH406B2G EZH406D4G
480 EZH405A2G EZH405X2G EZH405B2G EZH405D4G
ANSI
LAMP
M-98
M-90
M-575
M-58
M-59
EZ 70-400 WATT, METAL HALIDE 146
CATALOG NUMBER
PENDANT 3/4"2CEILING 3/4"2WALL 3/4"2STANCHION 1-1/4"3
WATTS VOLTAGE @ 60HZ
1See Hazardous Location Application Data on pages L164-165 for specific suitabilities.
2For 1 inch pendant, ceiling and wall hubs, substitute “3” for “2” in catalog number; example: EZH070A3G.
3Stanchion conduit hub size supplied is 1-1/2" with 1-1/2" to 1-1/4" reducer for 1-1/4" mounting. (Refer to catalog logic).
4Luminaire catalog numbers include guards. To order luminaire without guard, omit last letter “G” from catalog number.
5Will also operate 150W M107 Metal Halide Lamps.
6175, 250, 400W MH EXPORT ONLY (EISA LAW).
NOTE: Reflectors must be ordered separately (see page L161).
All luminaires are designed for mounting with lamp in base up position.
Pendant Ceiling Wall Stanchion
EZ SERIES LIGHTING
PULSE START METAL HALIDE 175-400W MOGUL BASE HID L159
ORDERING INFORMATION
L
Listed - File E10514 and E91793 (Marine)
Certified - File LR11713
Class I, Div. 1 & 2 Groups C,D
Class l, Zone 1 & 2, Groups llB,llA
Class l, Zone 1, AEx d IIB
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
Suitable for wet locations
Marine
NEMA 3, 4, 4X
Factory Sealed
120, 208, 240, 277 EZP150A2G EZP150X2G EZP150B2G EZP150D4G
150 120,277,347 EZP156A2G EZP156X2G EZP156B2G EZP156D4G
480 EZP155A2G EZP155X2G EZP155B2G EZP155D4G
120, 208, 240, 277 EZP170A2G EZP170X2G EZP170B2G EZP170D4G
175 120,277,347 EZP176A2G EZP176X2G EZP176B2G EZP176D4G
480 EZP175A2G EZP175X2G EZP175B2G EZP175D4G
120, 208, 240, 277 EZP250A2G EZP250X2G EZP250B2G EZP250D4G
250 120,277,347 EZP256A2G EZP256X2G EZP256B2G EZP256D4G
480 EZP255A2G EZP255X2G EZP255B2G EZP255D4G
120, 208, 240, 277 EZP320A2G EZP320X2G EZP320B2G EZP320D4G
320 120,277,347 EZP326A2G EZP326X2G EZP326B2G EZP326D4G
480 EZP325A2G EZP325X2G EZP325B2G EZP325D4G
120, 208, 240, 277 EZP350A2G EZP350X2G EZP350B2G EZP350D4G
350 120,277,347 EZP356A2G EZP356X2G EZP356B2G EZP356D4G
480 EZP355A2G EZP355X2G EZP355B2G EZP355D4G
120, 208, 240, 277 EZP400A2G EZP400X2G EZP400B2G EZP400D4G
400 120,277,347 EZP406A2G EZP406X2G EZP406B2G EZP406D4G
480 EZP405A2G EZP405X2G EZP405B2G EZP405D4G
EZ 175-400 WATT, PULSE START METAL HALIDE 1 4
ANSI
LAMP
CATALOG NUMBER
VOLTAGE @ 60Hz PENDA NT 3/4"2CEILING 3/4"2WALL 3/4"2STANCHION 1-1/4"3
1See Hazardous Location Application Data on pages L164-165 for specific suitabilities.
2For 1 inch pendant, ceiling and wall hubs, substitute “3” for “2” in catalog number; example: EZP170A3G.
3Stanchion conduit hub size supplied is 1-1/2" with 1-1/2" to 1-1/4" reducer for 1-1/4" mounting. (Refer to catalog logic).
4Luminaire catalog numbers include guards. To order luminaire without guard, omit last letter “G” from catalog number.
NOTE: Reflectors must be ordered separately (see page L161).
All luminaires are designed for mounting with lamp in base up position.
Pendant Ceiling Wall Stanchion
WATTS
M-102
M-142
M-137
M-138
M-132
M-131
M-135
EZ SERIES LIGHTING
COMPONENT PARTS/ACCESSORIES/OPTIONS HID FIXTURES
L160
EZ Options
Instant Restart Option
Factory installed special ignitor provides hot lamp instant
restart of HPS lamps after power interruption of up to
1 minute. Available for 50, 70, 100 and 150 watt HPS lamps
only. Add suffix “R” to fixture catalog number (50/60 Hz).
Quartz Emergency Lamp
Factory installed special auxiliary quartz relay and D.C. bayo-
net base socket installed to accept 100 watt, 120 volt quartz
(100Q/DC) lamps only. Lamps not supplied. Refer to
Hazardous Location Application Data chart to verify suitability.
Add suffix “Q” to fixture catalog number.
Ballast Protection Cutout
Optional factory installed special ballast protector replaces
the standard HPS ignitor and applies starting pulse to the
lamp for 10 to 15 seconds each time voltage is supplied to
the ballast. If the lamp has not ignited by the end of the time
period, the starter will cease pulsing. Used to eliminate the
continuous high voltage pulsing of the ignitor when end of
life, lamp cycling, or missing lamp conditions exist. Available
for 70, 100, 150, 250 and 400 watt HPS fixtures. Add suffix
BP” to fixture catalog number.
CATALOG NUMBER
EZGS1
EZGS2
LAMP TYPE
HPS
MH
MHP
HPS
MH
MHP
SERIES
EZS
EZH
EZP
EZS
EZH
EZP
WATTAGE
50-150
70-250
150, 175, 250
250, 400
400
320-400
REPLACEMENT GLOBE & GLOBE SUPPORT ASSEMBLY
CATALOG NUMBER
PENDANT CEILING BRACKET STANCHION
EZA2 EZX2** EZB2
EZA3 EZX3 EZB3
—— —EZD4*
HUB SIZE
3/4"
1"
1-1/4"/1-1/2"
MOUNTING BOXES
25° Stanchion
Replacement Globe
& Support Assemblies
Wall Bracket
Mounting Boxes
EAC1
Pendant Ceiling
Notes:
BP & R cannot be used together.
Q & R cannot be used together.
* Supplied as 1-1/2" NPT with 1-1/2" x 1-1/4" reducer
** 25 cu. in. below EZTB tangs.
FACTORY SEALED
PHOTO CELL FIELD KITS
WITH HKB-GL BOX AND COVER
VMHKPC1
VMHKPC2
VMHKPC3
CATALOG NUMBER
120VAC
208-277VAC
347VAC
VOLTS
Class I, DIV. 1 BCD
Class II, DIV. 1&2 EFG
CLASS III
NEMA 3, 4X IP66
*40˚C ambient T3 Rated
EZCUP
Close up plug for EZ mounting boxes.
Used for maintenance when fixture is
removed for service.
HIC-BEIGE
replacement wiring
plug for EZBx
Wall Bracket
EZ SERIES LIGHTING
COMPONENT PARTS/ACCESSORIES L161
L
CATALOG NUMBER DESCRIPTION
EZTB Female (goes in splice box)
EZCB Male (goes in top of fixture body)
EZMO Replacement lamp socket with gasket
REPLACEMENT CONNECTION BLOCKS AND LAMP SOCKET
CATALOG NUMBER DESCRIPTION
VMPSD40 Standard dome. fiberglass reinforced polyester
VMPA40 30°Angle fiberglass reinforced polyester
HRD400 Deep dome. Aluminum with white finish2
HRD400ALZ Deep dome with specular anaodized finish2
REFLECTORS
CATALOG NUMBER SERIES LAMP TYPE WATTAGE DESCRIPTION
EZS HPS 50-150
EZG1 EZH M H 7 0 - 2 50 Painted cast aluminum
EZP MHP 150, 175, 250
EZH MH 400 Cadmium plated steelVMAG40S EZP MHP 320-400
GUARDS
VMPSD-40
VMPA-40 HRD-400 (pictured)
HRD-400ALZ
EZTB
EZCB EZMO
EZG1 VMAG40S
2For clearance, wall mount models require standoff of 1/2" if not bottom feed;
1-1/2" if bottom feed.
1For VMAG40S with bottom
closure order part number
VMAG40SBC.
VMAGBC
Bottom Closure for
VMAG25S or VMAG40S1
EZ SERIES LIGHTING
BALLAST HOUSING WITH GLOBE SUPPORT ASSEMBLY
L162
FEATURES-SPECIFICATIONS
CATALOG
NUMBER
EZS050
EZS058
EZS070
EZS075
EZS076
EZS078
EZS100
EZS105
EZS106
EZS108
EZS150
EZS155
EZS156
EZS158
EZS250
EZS255
EZS256
EZS258
EZS400
EZS405
EZS406
EZS408
VOLTAGE
120, 208, 240, 277/60Hz
220, 240V/50Hz
120, 208, 240, 277/60Hz
480 60Hz
120, 277, 347/60Hz
220, 240V/50Hz
120, 208, 240, 277/60Hz
480 60Hz
120, 277, 347/60Hz
220, 240V/50Hz
120, 208, 240, 277/60Hz
480 60Hz
120, 277, 347/60Hz
220, 240V/50Hz
120, 208, 240, 277/60Hz
480 60Hz
120, 277, 347/60Hz
220, 240V/50Hz
120, 208, 240, 277/60Hz
480 60Hz
120, 277, 347/60Hz
220, 240V/50Hz
WATTS
50
70
100
150
250
400
ANSI LAMP
TYPE
S-68/HPS
S-62/HPS
S-54/HPS
S-55/HPS
S-50/HPS
S-51/HPS
HPS HOUSING GLOBE & GLOBE SUPPORT ASSEMBLIES1
CATALOG
NUMBER
EZH070
EZH076
EZH075
EZH078
EZH100
EZH106
EZH108
EZH105
EZH170
EZH175
EZH176
EZH178
EZH250
EZH255
EZH256
EZH258
EZH400
EZH405
EZH406
EZH408
METAL HALIDE HOUSING GLOBE & GLOBE SUPPORT ASSEMBLIES1
Housing Globe & Globe Support
Assemblies
NOTE: See pages L98-99 for
ballast data & fuse kit information.
VOLTAGE
120, 208, 240, 277/60Hz
120, 277, 347V/60Hz
480 60 H z
220/240V/50Hz
120, 208, 240, 277/60Hz
120, 347V/60Hz
120, 220, 240V/50Hz
480 60 H z
120, 208, 240, 277/60Hz
480 60Hz
120, 277, 347V/60Hz
220, 240V/50Hz
120, 208, 240, 277/60Hz
480 60Hz
120, 277, 347V/60Hz
220, 240V/50Hz
120, 208, 240, 277/60Hz
480 60Hz
120, 277, 347V/60Hz
220, 240V/50Hz
WATTS
70
100
175
250
400
ANSI LAMP
TYPE
M-98/MH
M-90/MH
M-57/MH
M-58/MH
M-59/MH
CATALOG
NUMBER
EZP170
EZP175
EZP176
EZP178
EZP250
EZP255
EZP256
EZP258
EZP320
EZP325
EZP326
EZP328
EZP350
EZP355
EZP356
EZP358
EZP400
EZP405
EZP406
EZP408
VOLTAGE
120, 208, 240, 277/60Hz
480
120, 277, 347V/60Hz
220, 240V/50 Hz
120, 208, 240, 277/60Hz
480
120, 277, 347V/60Hz
220, 240V/50Hz
120, 208, 240, 277/60Hz
480
120, 277, 347V/60Hz
220, 240V/50Hz
120, 208, 240, 277/60Hz
480
120, 277, 347V/60Hz
220, 240V/50Hz
120, 208, 240, 277/60Hz
480
120, 277, 347V/60Hz
220, 240V/50Hz
WATTS
1752
250
320
350
400
ANSI LAMP
TYPE
M137/MHP
M138/MHP
M132/MHP
M131/MHP
M135/MHP
PULSE START HOUSING GLOBE & GLOBE SUPPORT ASSEMBLIES
1HPS and MH assemblies may be ordered with the CEN (CENELEC) suffix;
see page L164 for more information.
2For 150 Watt, change “7” to “5” in catalog number.
Example EZP150.
EZ SERIES LIGHTING
DIMENSIONS L163
L
PENDANT CEILING BRACKET STANCHION
ABC DABCDABCDABC
50-250W* 22" 21-1/4" 11-1/4" 18" 22" 21-1/4" 11-1/4" 18" 22-7/8" 22-1/8" 16-3/4" 18" 24-7/8" 24" 19-13/16"
(558) (539) (285) (457) (558) (539) (285) (457) (580) (561) (425) (457) (631) (609) (503)
250-400W** 26-1/4" 24-1/4" 11-1/4" 22-1/4" 26-1/4" 24-1/4" 11-1/4" 22-1/4" 26-7/8" 24-7/8" 16-3/4" 22-1/4" 28-1/2" 26-11/16" 21-1/2"
(666) (615) (285) (565) (666) (615) (285) (565) (682) (631) (425) (565) (724) (678) (546)
MOUNTING DIMENSIONS
Pendant Ceiling Wall Bracket 25° Stanchion
Standard Dome Angle Deep Dome
Reflector Dimensions
* 50, 70, 100, and 150W HPS; 70, 100, 175 and 250W MH; 150, 175, 250W MHP.
** 250 and 400W HPS, 400W MH; 320, 350, 400W MHP.
.31"
(8) 5.25"
EZ SERIES LIGHTING
CLASS I APPLICATION DATA FOR HAZARDOUS LOCATIONS
L164
SUPPLY CLASS I, DIVISIONS 1 & 2
LAMP RATED WIRE MAXIMUM SURFACE TEMPERATURE
AMBIENT SUITABLE UL/CSA
SERIES TYPE WATTS °C FOR °C TEMP. I.D. TEMP. I.D. UL/CSA
MIN. W/O QTZ. W/QTZ.3GROUPS
40 85 T5 T4 C,D
50 55 85 T5 N/A C,D
65 85 T4A N/A C,D
40 85 T5 T4 C,D
70 55 85 T5 N/A C,D
65 85 T4A N/A C,D
EZS HPS 40 85 T5 T4 C,D
100 55 85 T5 N/A C,D
65 85 T4A N/A C,D
40 85 T4A T4 C,D
150 55 85 T4A N/A C,D
65 85 T4 N/A C,D
250 40 85 T3C T3C C,D
55 85 T3C N/A C,D
400 40 85 T3C T3C C,D
40 85 T4A N/A C,D
70 55 85 T4A N/A C,D
65 85 T4A N/A C,D
40 85 T4A N/A C,D
100 55 85 T4A N/A C,D
EZH MH 65 85 T4A N/A C,D
40 85 T4 T3C C,D
175 55 85 T4 N/A C,D
40 85 T3C T3C C,D
250 55 85 T3C N/A C,D
400 40 85 T3A T3A C,D
40 85 T4 T3C C,D
55 85 T4 N/A C,D
40 85 T3C T3C C,D
EZP MHP 250 55 25 T3C N/A C,D
320 40 85 T3A T3A C,D
350 40 85 T3A T3A C,D
400 40 85 T3A T3A C,D
EZ HAZARDOUS LOCATION DATA—CLASS I, DIVISIONS 1 & 2124
See page L165 for Class II, III tables.
CEN Option
Applications
Killark EZ series fixtures are available with a
European “Certificate of Conformity” from
PTB (Physikalisch-Technische
Bundesanstalt), the approval agency
based in Germany. Fixtures with this rating
will be useful for Original Equipment
Manufacturers and others who build and
ship apparatus into European markets.
This approval is granted by PTB with the
use of a special ground lug and label.
Fixtures carrying an EEx d llB approval are
automatically granted an IP54 (ingress pro-
tection) rating. See Temperature Code
chart below for PTB certified ratings. Killark
EZ fixtures with the PTB rating and labels
still carry all UL & CSA ratings.
Fixture housing/globe/globe support
assemblies (e.g. EMS050 CEN) may be
ordered with the CEN suffix. Complete fix-
ture numbers, with the CEN suffix, will be
shipped with the mounting boxes, guards
and accessories as component parts.
Reflectors and other accessory parts, as
listed on pages L144-145, may be used.
Killark fixtures are NPT tapped and
plugged with at least one conduit
hole open.
Compliances
EN 50014:1992
EN 50018:1994
EEx d IIB T6 (or T5-T2)
PTB No. Ex-98.E.1076
Notes for Class I, II, III Application Data Tables.
1Instant restrike limited to 55°C ambient maximum.
2Temperature code ID marked with an asterisk on Class ll table are listed for simultaneous
use in Class I, Groups C, D, and Class II, Groups E, F, G or Groups E, F.
3Fixtures marked “N/A” not suitable for Class ll applications when supplied with auxiliary
quartz.
4See Class II table for fixtures suitable for locations having deposits of readily combustible
paint residue (paint spray booths).
Do not install where marked operating temperature exceeds ignition temperature of haz-
ardous atmosphere.
MAXIMUM AMBIENT TEMPERATURE RANGE -20°C TO 40°C
TYPE OF
LUMINAIRE
EZH50
EZH70
EZH10
EZH15
EZH17
EZH25
EZH40
EZS50
EZS70
EZS10
EZS15
EZS25
EZS40
TYPE OF
ENCLOSURE
EZO25
EZO25
EZO25
EZO25
EZO25
EZO25
EZO40
EZO25
EZO25
EZO25
EZO25
EZO40
EZO40
FORM OF
THE LAMP
ED28/M-110
ED28/M-98
ED28/M-90
ED28/M-102
ED28/M-57
ED28/M-58
ED37/M-59
ED23-1/2/S-68
ED23-1/2/S-62
ED23-1/2/S-54
ED23-1/2/S-55
ED18/S-50
ED18/S-51
MAXIMUM
WATTAGE
50W
70W
100W
150W
175W
250W
400W
50W
70W
100W
150W
250W
400W
TEMPERATURE
CLASS
T4
T4
T4
T4
T4
T3
T3
T4
T4
T4
T4
T3
T3
150 or 175
*
EZ SERIES LIGHTING
CLASS II/III APPLICATION DATA FOR HAZARDOUS LOCATIONS L165
L
Notes for Class I, II, III Application Data Tables.
1Instant restrike limited to 55°C ambient maximum.
2Temperature code ID marked with an asterisk on Class ll table are listed for simultaneous use in Class I, Groups C, D, and Class II, Groups E, F, G or Groups E, F.
3Fixtures marked “NO” or “N/A” are not suitable for Class ll or II applications when supplied with auxiliary quartz.
4Suitability for locations having deposits of readily combustible paint residue (paint spray booths).
Do not install where marked operating temperature exceeds ignition temperature of hazardous atmosphere.
EZ HAZARDOUS LOCATION DATA1–CLASS II & III, DIVISIONS 1 & 21 2
E,F,G
N/A
N/A
E,F,G
N/A
N/A
E,F,G
N/A
N/A
E,F,G
N/A
N/A
E,F
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
EF
N/A
N/A
N/A
N/A
SUPPLY
WIRE
SUITABLE
FOR C°
See page L164 for Class l data.
CLASS III, DIV. 1 & 2
UL/CSA SUITABILITY
W/O QTZ. WITH QTZ.3
YES YES YES YES YES
YES NO YES NO YES
YES NO YES NO YES
YES NO YES YES YES
YES NO YES NO YES
YES YES YES NO YES
YES NO YES YES YES
YES NO YES NO YES
YES YES YES NO YES
YES YES YES NO YES
YES YES YES NO YES
YES YES YES NO YES
NO NO YES NO YES
NO NO YES NO YES
YES NO YES YES YES
YES NO YES NO YES
YES NO YES NO YES
YES NO YES YES YES
YES NO YES NO YES
YES NO YES NO YES
YES NO YES NO YES
YES NO YES NO YES
NO NO YES NO YES
NO NO YES NO YES
YES NO YES NO YES
YES NO YES NO YES
NO NO YES NO YES
NO NO YES NO YES
NO NO YES NO YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
TEMP. I.D.
W/O QTZ. W/O QTZ.
TEMP. I.D.
WITH QTZ
3
WITH QTZ
3
CLASS II, DIV. 1 & 2, MAX. SURFACE
TEMP. UL/CSA SUITABILITY
GROUPS
I.D.
NUMBER
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6
TABLE N.E.C. 500-5 (d)
DEGREES C
450
300
280
260
230
215
200
180
165
160
135
120
100
85
DEGREES F
842
572
536
500
446
419
392
356
329
320
275
248
212
185
*
LAMP
LAMP
RATED
AMBIENT
°C
40 85 T3C* T3B* E,F
EZS HPS 50 55 85 T3C* N/A E,F,G
85 T3B* N/A E,F,G
85 T3C* T3B* E,F,G
EZS HPS 70 55 85 T3C* N/A E,F,G
65 85 T3B* N/A E,F,G
40 85 T3C* T3B* E,F,G
EZS HPS 100 55 85 T3C* N/A E,F,G
65 85 T3B N/A E,F,G
40 85 T3C* T3B* E,F,G
EZS HPS 150 55 85 T3C* N/A E,F,
65 85 T3B* N/A E,F,G
EZS HPS 250 40 85 T3 T3 E,F
EZS HPS 400 40 85 N/A N/A N/A
40 85 T4A N/A E,F,
EZH MH 70 55 85 T4 N/A E,F,G
65 85 T3C N/A E,F,
40 85 T4A N/A E,F,G
EZH MH 100 55 85 T4 N/A E,F,G
65 85 T3C N/A E,F,G
EZH MH 175 40 85 T3C* T3A* E,F,G
55 85 T3C* N/A E,F,G
EZH MH 250 40 85 N/A N/A N/A
EZH MH 400 40 85 N/A N/A N/A
EZP MHP 150 or 40 85 T3C* T3A* E,F,G
175 55 85 T3C* N/A E,F,G
EZP MHP 250 40 85 N/A N/A N/A
EZP MHP 320, 350 40 85 N/A N/A N/A
EZP MHP 400 40 85 N/A N/A N/A
UL-595
MARINE
UL/CSA
TYPE 3
(RAINTIGHT)
UL/CSA
TYPE 4
(HOSEDOWN)
U.L. PAINT
SPRAY
SUITABILITY4
EZ SERIES • LIGHTING
PHOTOMETRIC DATA • HID FIXTURES
L166
Test No. LSI-9182
HIGH PRESSURE SODIUM
With Globe Only
50 – 150 Watt Mogul Base
CANDLEPOWER – 100 WATT
E-2312clear lamp
9500 lumens
For 50 watt multiply by .42
For 70 watt multiply by .67
For 150 watt multiply by 1.68
HIGH PRESSURE SODIUM
With Globe and Standard Dome Reflector
50 – 150 Watt Mogul Base
CANDLEPOWER – 100 WATT
E-2312clear lamp
9500 lumens
For 50 watt multiply by .42
For 70 watt multiply by .67
For 150 watt multiply by 1.68
Test No. LSI-9228 Test No. LSI-9230
HIGH PRESSURE SODIUM
With Globe and Deep Dome HRD-400 Reflector
50 – 150 Watt Mogul Base
CANDLEPOWER – 100 WATT
E-2312clear lamp
9500 lumens
For 50 watt multiply by .42
For 70 watt multiply by .67
For 150 watt multiply by 1.68
EZ SERIES • LIGHTING
PHOTOMETRIC DATA • HID FIXTURES
HIGH PRESSURE SODIUM
With Globe and Angle Reflector
50 – 150 Watt Mogul Base
CANDLEPOWER – 100 WATT
E-2312clear lamp
9500 lumens
For 50 watt multiply by .42
For 70 watt multiply by .67
For 150 watt multiply by 1.68
HIGH PRESSURE SODIUM
With Globe Only
250 – 400 Watt Mogul Base
CANDLEPOWER – 400 WATT
E-18 clear lamp
50000 lumens
For 250 watt multiply by .60
HIGH PRESSURE SODIUM
With Globe and Standard Dome Reflector
250 – 400 Watt Mogul Base
CANDLEPOWER – 400 WATT
E-18 clear lamp
50000 lumens
For 250 watt multiply by .60
Test No. LSI-9229
Test No. LSI-9055 Test No. LSI-9056
L167
L
L
EZ SERIES • LIGHTING
PHOTOMETRIC DATA • HID FIXTURES
L168
L168
HIGH PRESSURE SODIUM
With Globe and Deep Dome HRD-400 Reflector
250 and 400 Watt Mogul Base
CANDLEPOWER – 400 WATT
E-18 clear lamp
50000 lumens
For 250 watt multiply by .60
HIGH PRESSURE SODIUM
With Globe and Angle Reflector
250 – 400 Watt Mogul Base
CANDLEPOWER – 400 WATT
E-18 clear lamp
50000 lumens
For 250 watt multiply by .60
Test No. LSI-9058 Test No. LSI-9057 Test No. LSI-9183
METAL HALIDE,
PULSE START METAL HALIDE
With Globe and Standard Dome Reflector
70 – 250 Watt Mogul Base
CANDLEPOWER – 175 WATT MH
E-28 coated MH (14000 lumens)
For CP of 70W MH multiply by .40
For CP of 100W MH multiply by .56
For CP of 150W MH multiply by .96
For CP of 250W MH multiply by 1.46
For CP of 175W MHP multiply by 1.14
For CP of 250W MHP multiply by 1.69
EZ SERIES • LIGHTING
PHOTOMETRIC DATA • HID FIXTURES L169
L169
L
Test No. LSI-9231 Test No. LSI-9233 Test No. LSI-9232
METAL HALIDE,
PULSE START METAL HALIDE
With Globe and Standard Dome Reflector
70 – 250 Watt Mogul Base
CANDLEPOWER – 175 WATT MH
E-28 coated MH (14000 lumens)
For CP of 70W MH multiply by .40
For CP of 100W MH multiply by .56
For CP of 150W MH multiply by .96
For CP of 250W MH multiply by 1.46
For CP of 175W MHP multiply by 1.14
For CP of 250W MHP multiply by 1.69
METAL HALIDE,
PULSE START METAL HALIDE
With Globe and Deep Dome HRD-400 Reflector
70 – 250 Watt Mogul Base
CANDLEPOWER – 175 WATT MH
E-28 coated MH (14000 lumens)
For CP of 70W MH multiply by .40
For CP of 100W MH multiply by .56
For CP of 150W MH multiply by .96
For CP of 250W MH multiply by 1.46
For CP of 175W MHP multiply by 1.14
For CP of 250W MHP multiply by 1.69
METAL HALIDE,
PULSE START METAL HALIDE
With Globe and Angle Reflector
70 – 250 Watt Mogul Base
CANDLEPOWER – 175 WATT MH
E-28 coated MH (14000 lumens)
For CP of 70W MH multiply by .40
For CP of 100W MH multiply by .56
For CP of 150W MH multiply by .96
For CP of 250W MH multiply by 1.46
For CP of 175W MHP multiply by 1.14
For CP of 250W MHP multiply by 1.69
EZ SERIES • LIGHTING
PHOTOMETRIC DATA • HID FIXTURES
L170
L170
Test No. LSI-9051 Test No. LSI-9052 Test No. LSI-9054
METAL HALIDE,
PULSE START METAL HALIDE
With Globe Only
320 - 400 Watt Mogul Base
CANDLEPOWER – 400 WATT MH
E-37 coated MH
36000 lumens
For CP of MHP320 multiply by .87
For CP of MHP350 multiply by 1.05
For CP of MHP400 multiply by 1.22
METAL HALIDE,
PULSE START METAL HALIDE
With Globe and Standard Dome Reflector
320 - 400 Watt Mogul Base
CANDLEPOWER – 400 WATT MH
E-37 coated MH
36000 lumens
For CP of MHP320 multiply by .87
For CP of MHP350 multiply by 1.05
For CP of MHP400 multiply by 1.22
METAL HALIDE,
PULSE START METAL HALIDE
With Globe and Deep Dome Reflector
320 - 400 Watt Mogul Base
CANDLEPOWER – 400 WATT MH
E-37 coated MH
36000 lumens
For CP of MHP320 multiply by .87
For CP of MHP350 multiply by 1.05
For CP of MHP400 multiply by 1.22
EZ SERIES • LIGHTING
PHOTOMETRIC DATA • HID FIXTURES L171
L171
L
Test No. LSI-9053
METAL HALIDE,
PULSE START METAL HALIDE
With Globe and Angle Reflector
320 - 400 Watt Mogul Base
CANDLEPOWER – 400 WATT MH
E-37 coated MH
36000 lumens
For CP of MHP320 multiply by .87
For CP of MHP350 multiply by 1.05
For CP of MHP400 multiply by 1.22 POWERFUL
Luminaire Layout
and Calculation
Software
Software is used to determine number of fixtures required and their
proper layout for various tasks and applications.
Contact you local Killark sales representative for availability.
DESIGNDESIGN
LIGHTING DESIGN SOFTWARE
DBF SERIES • LIGHTING
FLUORESCENT FIXTURES
L172
L172
FEATURES-SPECIFICATIONS
Listed - File E12976
Certified - File LR11713
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups llC,llB,llA
Class II, Div. 1 & 2, Groups E,F,G5
Class III, Div. 1 & 2
Suitable for wet locations
NEMA 3, 4
Applications
LINEARLITE DBF fluorescent fixtures
are designed for general and task light-
ing of areas where flammable gases or
vapors or combustible dusts may exist
due to abnormal conditions resulting in
the creation of a Class I, Division 2 or
Class II or III, Div. 1 or 2, hazardous
location as defined in the NEC. Also
for lighting non-hazardous wet loca-
tions indoors and outdoors.
Features
Sheet steel 20 ga. housing with con-
tinuous weld prevents foreign matter
from entering enclosure
Lens frame assembly has silicon
rubber gasketing and heat tempered
glass lens
Electrostatically applied
polyester finish
CATALOG CONDUIT NUMBER LINE
NUMBER SIZE3OF LAMPS VOLTAGE DESCRIPTION
DBF32302 120-277V 50/60 Hz 32W T8 electronic ballast 265 MA 0°F start
DBF40124120V 60 Hz
DBF4042 3/4" 2 277V 60 Hz 40W rapid start electronic F40T12 medium bi-pin 430MA
DBF60124120V 60 Hz 60W rapid start high output F48T12/HO recessed
DBF6042 277V 60 Hz double contact 800MA
DBF32303 120-277V 50/60 Hz 32W T8 electronic ballast 265 MA 0°F start
DBF4013
3/4" 3
120V 60 Hz 40W rapid start electronic F40T12 medium bi-pin 430MA
DBF4043 277V 60 Hz
DBF6013 120V 60 Hz 60W rapid start high output F48T12/HO recessed
DBF6043 277V 60 Hz double contact 800MA
DBF FLUORESCENT FIXTURES
CATALOG NUMBER DESCRIPTION
ABK Angle bar chain bracket
AFK 45° fixed angle bracket
AAK 45° adjustable angle bracket
DBF-HUB Replacement hub
DBF-DL Door & Lens
MOUNTING HARDWARE2
SUPPLY CLASS I, DIV. 2, CLASS II, DIV. 1 & 2,
NUMBER LAMP RATED WIRE GROUPS A, B, C, D GROUPS E, F, G CLASS III NEMA NEMA
OF AMBIENT MAX. LAMP MAX. SURFACE DIV. 1 & 2 TYPE 3 TYPE 4
LAMPS WATTS °C SUITABLE TEMP.°C TEMP. °CSUITABILITY UL/CSA (RAINTIGHT) (HOSEDOWN)
FOR °C MIN. UL/CSA TEMP/I.D. UL/CSA TEMP/I.D.
2 32/40 40 90 T6 (85°C/185°F) T6 (85°C/185°F) YES YES YES
3 32/40 40 90 T5 (100°C/212°F) T6 (85°C/185°F) YES YES YES
2 60 40 90 T4A (120°C/248°F) T6 (85°C/185°F) YES YES YES
3 60 40 90 T4 (138°C/275°F) T6 (85°C/185°F) YES YES YES
DBF HAZARDOUS LOCATION APPLICATION DATA15
Standard ballast starting temperature for 40 watt is 50°F.
Ballasts are Class P Type with internal, automatic, thermally-activated protective device.
Optional external ballast fusing availability by adding suffix FB.
For other voltages consult factory.
60 watt high output ballasts are standard -20°F start.
Fixtures are supplied without lamps. To order with lamps installed add suffix WL.
1UL/CSA Class I, Div. 2
3Hubs can be relocated in field to fixture end for feed-thru wiring.
4Change 1 to 8 for 230V 50 Hz.
5CSA Class II, Div. I
2Must be ordered separately. Brackets sold as sets.
AFK AAK
ABK
SEE PAGE L208
FOR DBFE
EMERGENCY MODELS
LZ2S SERIES • LIGHTING
316 STAINLESS FLUORESCENT FIXTURES L173
L173
L
Certified - File LR11713
Class I, Div. 2, Groups A,B,C,D
Class l, Zone 2, Groups llC, llB, llA
Class II, Div. 1 & 2, Group E,F,G
AEx nAII, Ex nAII
Wet Locations
NEMA 4X, IP66
Type Approval
ABS
LZ2S STAINLESS
Applications
LINEARLITE®rugged 316 stainless fluo-
rescent fixtures are suitable for wet, harsh,
corrosive and hazardous locations. The
LZ2S Series can be used in Class I, Divi-
sion 2 and Zone 2 hazardous vapors and
in Class II combustible dust areas typically
found in refineries, chemical plants, waste
water & sewage treatment facilities, as
well as in tunnels, food processing and
coastal areas.
ABS (American Bureau of Shipping) type
approval for use on decks, vessels, plat-
forms, barges, ships and boats. Also
suitable for docks and marinas.
Features
NEMA 4X & IP66 rated stainless enclo-
sure with Lexan®impact resistant poly-
carbonate lens.
Two 3/4" NPT stainless hubs - one at
each end (includes aluminum 3/4" close-
up plug and two 3/4" x 1/2" reducers for
maximum user flexibility).
Two 1/4" - 20 stainless bushings furnished
in top of fixture for threaded rod.
Lexan®is a registered trademark of General Electric
Additional Data
L209 - Emergency models
L175 - Ballast data
L176 - Mounting accessories/
Replacement parts
L176 - L177 - Photometrics
150 Hz ballast is magnetic.
2Add suffix 55C for 2X 32W 120V-277V # L32S32230-55C.
3L32SE, 40°C max. battery models.
4T-code measured at 40°C.
NUMBER OF
LAMPS/WATTS
1-40W
1-55W
2-40W
4-40W
2-17W
3-17W
2-28W
3-28W
2-32W2
3-32W
2-40W
2-44W
2-54W
3-54W
2-60W
BIAXIAL LAMP TYPE FIXTURES
VOLTAGE
AC 60 Hz
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
50-60 Hz
120-277V
50-60 Hz
120-277V
347 V
120-277V
347 V
120 V
277 V
230 V 50 Hz1
120 V
277 V
120-277V
120-277V
DOUBLE-ENDED LAMP TYPE FIXTURES
DESCRIPTION
2' 1-Lamp Biaxial Electronic 50/60 Hz, 0°F Start 4-Pin
2' 1-Lamp Biaxial Electronic 50/60 Hz, 0°F Start 4-Pin
2' 2-Lamp Biaxial Electronic 50/60 Hz, 0°F Start 4-Pin
4' 4-Lamp Biaxial Electronic 50/60 Hz, 0°F Start 4-Pin
2' 2-Lamp T-8 Electronic 50/60 Hz, 0°F Start Medium Bi-Pin
2' 3-Lamp T-8 Electronic 50/60 Hz, 0°F Start Medium Bi-Pin
4' 2-Lamp T-5 Electronic 0°F Start Miniature Bi-Pin
4' 3-Lamp T-5 Electronic 0°F Start Miniature Bi-Pin
4' 2-Lamp T-8 Electronic 50/60 Hz 0°F Start Medium Bi-Pin
4' 3-Lamp T-8 Electronic 50/60 Hz 0°F Start Medium Bi-Pin
4' 2-Lamp T-12 Electronic Medium Bi-Pin Start 50°F 40W/60°F 34W
4' 2-Lamp T-8 Electronic -20°F Start High Output
Recessed Double Contact
4' 2-Lamp T5 Electronic 50/60 Hz, -20°F Start Miniature Bi-Pin
4' 2-Lamp T-12 Electronic -20°F Start High Output
Recessed Double Contact
NUMBER OF RATED SUITABLE CLASS I, DIV, 2 CLASS II, DIV. 1 & 2 CLASS III
AMBIENT FOR °C MAX. SURFACE TEMP. MAX. SURFACE TEMP. DIV. 1 & 2
LAMPS/WATTS °C SUPPLY WIRE TEMP. T-CODE GROUPS TEMP. T-CODE GROUPS SUITABILITY
1 X 40W BIAXIAL 4 75 160°C T3C A, B, C, D 100°C T5 E, F, G Yes
1 X 55W BIAXIAL 4 60 16C T3C A, B, C, D 100°C T5 E, F, G Yes
2 X 40W BIAXIAL 40° 75 160°C T3C A, B, C, D 100°C T5 E, F, G Yes
4 X 40W BIAXIAL 40° 75 160°C T3C A, B, C, D 100°C T5 E, F, G Yes
2 X 17W 40° 60 8C T5 A, B, C, D 100°C T5 E, F, G Yes
3 X 17W 40° 60 8C T5 A, B, C, D 100°C T5 E, F, G Yes
2 X 28W 40° 60 120°C T4A A, B, C, D 10C T5 E, F, G Yes
3 X 28W 40° 60 120°C T4A A, B, C, D 10C T5 E, F, G Yes
2 X 32W 40° 60 85°C T6 A, B, C, D 100°C T5 E, F, G Yes
2 X 32W 5390 100°C T5 A, B, C, D N/A N/A N/A Yes
3 X 32W 40° 60 85°C T6 A, B, C, D 100°C T5 E, F, G Yes
2 X 40W 40° 60 120°C T4A A, B, C, D 10C T5 E, F, G Yes
2 X 44W 40° 60 120°C T4A A, B, C, D 10C T5 E, F, G Yes
2 X 54W 40° 75 160°C T3C A, B, C, D 10C T5 E, F, G Yes
3 X 54W 35°475 180°C T3A A, B, C, D N/A N/A N/A Yes
2 X 60W 40° 75 135°C T4 A, B, C, D 100°C T5 E, F, G Yes
LZ2S, LZ2SE HAZARDOUS LOCATION APPLICATION DATA
LZ2S
LZ2S40130
LZ2S55130
LZ2S40230
LZ2S40430
LZ2S17230
LZ2S17330
LZ2S28230
LZ2S28330
LZ2S32230
2
LZ2S32215
LZ2S32330
LZ2S32315
LZ2S40201
LZ2S40204
LZ2S40208
LZ2S44230
LZ2S54230
LZ2S54330
LZ2S60230
See LZ2N
Logic for
Options
LZ2N SERIES LIGHTING
NON-METALLIC FLUORESCENT FIXTURES
L174
L174
FEATURES-SPECIFICATIONS
Certified - File LR11713
Class I, Div. 2 Groups A,B,C,D
Class l, Zones 2, Groups IIC,llB,llA
Class II, Div. 1 & 2, Groups F,G
AEx nAII, Ex nAII
Wet Locations
NEMA 4X, IP66
4’ Nominal Style
2’ Nominal Style
Type Approval
ABS
Food Handling
NSF
Quick release diffuser clamp and hinged cover
requires no special tools.
Applications
LINEARLITE ®rugged Non-Metallic fluo-
rescent fixtures are suitable for wet, harsh
and hazardous locations. Use where
enclosed and gasketed fixtures are
required to withstand exposure to mois-
ture, dust and corrosives. The LZ2N
Series can also be used in Class I,
Division 2 and Zone 2 hazarous vapors
and in Class II areas where combustible
dusts may exist. Typical areas used are in
refineries, chemical plants, waste water &
sewage treatment facilities, as well as in
tunnels, food processing and coastal
areas.
ABS (American Bureau of Shipping) type
approval for use on decks, vessels, plat-
forms, barges, ships and boats. Also suit-
able for docks and marinas.
NSF (National Sanitation Foundation)
approved for “Food Handling” areas, typi-
cally requiring non-glass lighting.
Features
Housing-one piece fiberglass reinforced
polyester, NEMA 4X & IP66 rated.
Lexan®Clear Lens, impact resistant
polycarbonate
Two 3/4" NTP aluminum hubs - one at
each end (includes one 3/4" close-up
plug and two 3/4" x 1/2" reducers for
maximum user flexibility)
Two 1/4"-20 aluminum bushings fur-
nished in top of fixture for threaded rod
2’ and 4’ luminaries
Lamp types-
Linear 17, 28, 32, 40, 44, 54, 60W
Long compact 40, 55W (single ended)
Electronic ballast standard
World voltage (most models) 120 thru
277V, 50/60 Hz
Lexan®is a registered trademark of General Electric
Catalog Number Logic
Constant for LZ2N Series
1Emergency (Battery backed)
E1—40W BIAXIAL, 44W, 60W
E2—32W, 40W
Lamp Wattage
17
28
32
40-Linear & BIAXIAL
44
54
55
60
Voltage
30—120-277V 50/60 Hz
40, 55 - BIAXIAL
17, 28, 32, 44, 54W
01—120V 60 Hz
40W, 60W
04—277V 60 Hz
40W, 60W
08—230V 50 Hz
40W
15—347V 60 Hz
32W
LZ2N - (E0-) - 00 - 0 - 00 - F2
NUMBER OF RATED SUITABLE CLASS I, DIV, 2 CLASS II, DIV, 1 & 2 CLASS III NEMA 4X
AMBIENT FOR °C MAX. SURFACE TEMP. MAX. SURFACE TEMP. DIV. 1 & 2
LAMPS/WATTS °C SUPPLY WIRE TEMP. T-CODE GROUPS TEMP. T-CODE GROUPS SUITABILITY IP66
2 X 17W 40° 60 85°C T5 A, B, C, D 100°C T5 F, G Yes Yes
3 X 17W 40° 60 85°C T5 A, B, C, D 100°C T5 F, G Yes Yes
1 X 40W BIAXIAL 40° 60 100°C T5 A, B, C, D 100°C T5 F, G Yes Yes
1 X 55W BIAXIAL 40° 60 160°C T3C A, B, C, D 100°C T5 F, G Yes Yes
2 X 40W BIAXIAL 40° 60 100°C T5 A, B, C, D 100°C T5 F, G Yes Yes
4 X 40W BIAXIAL 40° 60 120°C T4A A, B, C, D 10C T5 F, G Yes Yes
2 X 28W 40° 60 120°C T4A A, B, C, D 10C T5 F, G Yes Yes
3 X 28W 4 60 120°C T4A A, B, C, D 100°C T5 F, G Yes Yes
2 X 32W 40° 75 85°C T6 A, B, C, D 100°C T5 F, G Yes Yes
2 X 32W 5190 100°C T5 A, B, C, D N/A N/A N/A Yes Yes
3 X 32W 4 75 85°C T6 A, B, C, D 100°C T5 F, G Yes Yes
3 X 32W 55°190 100°C T5 A, B, C, D N/A N/A N/A Yes Yes
2 X 40W 4 60 120°C T4A A, B, C, D 100°C T5 F, G Yes Yes
2 X 44W 40° 60 100°C T5 A, B, C, D 100°C T5 F, G Yes Yes
2 X 54W T5 40° 75 160°C T3C A, B, C, D 10C T5 F, G Yes Yes
3 X 54W T5 40° 75 180°C T3A A, B, C, D 120°C T4A F, G Yes Yes
2 X 60W 40° 75 135°C T4 A, B, C, D 100°C T5 F, G Yes Yes
LZ2N, LZ2NE HAZARDOUS LOCATION APPLICATION DATA
1 lamp
2 lamps
3 lamps
4 lamps
F—single fuse2
FF—double fuse2
QD—Quick Disconnect
55C3
1See page L209 for complete catalog grid listing.
2Fuses not for marine or Canadian use.
355°C ambient suitability 2 or 3 lamp 32W C1D2 120V-277V only.
1LZ2NE, 40°C max. battery models.
LZ2N/LZ2S luminaires contain no exposed
glass and carry Class II, “G” ratings required
for many food proccessing areas.
LZ2N SERIES LIGHTING
NON-METALLIC FLUORESCENT FIXTURES L175
L175
L
LZ2NAND LZ2S BALLAST DATA1
LZ2N NON-METALLIC
NUMBER OF
LAMPS/WATTS
1-40W
1-55W
2-40W
4-40W
2-17W
3-17W
2-28W
3-28W
2-32W
3-32W
2-40W
2-44W
2-54W
3-54W
2-60W
BIAXIAL LAMP TYPE FIXTURES
VOLTAGE
A C 6 0 H z
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
347V
120-277V
347V
120V
277V
230V 50 Hz2
120-277V
120-277V
120-277V
120-277V
DOUBLE-ENDED LAMP TYPE FIXTURES
DESCRIPTION
2' 1-Lamp Biaxial Electronic 50/60 Hz
0°F Start 4-Pin
2' 1-Lamp Biaxial Electronic 50/60 Hz
0°F Start 4-Pin
2' 2-Lamp Biaxial Electronic 50/60 Hz
0°F Start 4-Pin
4' 4-Lamp Biaxial Electronic 50/60 Hz
0°F Start 4-Pin
2' 2-Lamp T8 Electronic 50/60 Hz
0°F Start Medium Bi-Pin
2' 3-Lamp T8 Electronic 50/60 Hz
0°F Start Medium Bi-Pin
4' 2-Lamp T-5 Electronic 50/60 Hz
0°F Start Miniature Bi-Pin
4' 3-Lamp T-5 Electronic 50/60 Hz
0°F Start Miniature Bi-Pin
4' 2-Lamp T-8 Electronic 50/60 Hz
0°F Start Medium Bi-Pin
4' 3-Lamp T-8 Electronic 50/60 Hz
0°F Start Medium Bi-Pin
4' 2-Lamp T-12 Electronic, Medium Bi-Pin
Start 50°F 40W/60°F 34W
4' 2-Lamp T-8 Electronic -20°F Start High Output 50/60 Hz
Recessed Double Contact
4' 2-Lamp T-5 Electronic 50/60 Hz
-20°F Start Miniature Bi-Pin
4' 2-Lamp T-5 Electronic 50/60 Hz
-20°F Start Miniature Bi-Pin
4' 2-Lamp T-12 Electronic -20°F Start High Output 50/60 Hz
Recessed Double Contact
LZ2N
LZ2N40130
LZ2N55130
LZ2N40230
LZ2N40430
LZ2N17230
LZ2N17330
LZ2N28230
LZ2N28330
LZ2N322304
LZ2N32215
LZ2N323304
LZ2N32315
LZ2N40201
LZ2N40204
LZ2N40208
LZ2N44230
LZ2N54230
LZ2N54330
LZ2N60230
1Includes normal powered LZ2NE and LZ2SE models, lamps not included.
2Magnetic ballast.
350°C 34T12; 60°F 40T12.
4See LOGIC for 55°C ambient suitability.
NUMBER OF
LAMPS/WATTS
1 X 40W BIAXIAL
1 X 55W BIAXIAL
2 X 40W BIAXIAL
4 X 40W BIAXIAL
2 X 1 7 W
3 X 1 7 W
2 X 2 8 W
3 X 2 8 W
2 X 3 2 W
3 X 3 2 W
2 X 4 0 W
2 X 4 4 W
2 X 5 4 W
3 X 5 4 W
2 X 6 0 W
VOLTAGE
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
.35 (120V)
.49 (120V)
.60 (120V)
1.32 (120V)
.32 (120V)
.39 (120V)
.55 (120V)
.83 (120V)
.54 (120V)
.71 (120V)
.62 (120V)
.84 (120V)
1.00 (120V)
1.52 (120V)
1.13 (120V)
.15 (277V)
.22 (277V)
.28 (277V)
.56 (277V)
.14 (277V)
.17 (277V)
.23 (277V)
.35 (277V)
.24 (277V)
.31 (277V)
.24 (277V)
.36 (277V)
.43 (277V)
.66 (277V)
.48 (277V)
LINE CURRENT AMPS
INPUT
W AT T S
3 9
5 8
7 8
156
3 8
4 8
6 6
9 9
6 5
8 5
7 1
9 9
120
182
125
STARTING
TEMPERATURE
0°F (-18°C)
0°F (-18°C)
0°F (-18°C)
0°F (-18°C)
0°F (-18°C)
0°F (-18°C)
0°F (-18°C)
0°F (-18°C)
0°F (-18°C)
0°F (-18°C)
50°F (10°C)3
-20°F (-29°C)
-20°F (-29°C)
-20°F (-29°C)
-20°F (-29°C)
See page L209
for LZ2NE
Non-metallic
and LZ2SE
316 Stainless
Emergency
Models
LZ2N, LZ2S, LZ2NE, LZ2SE SERIES LIGHTING
DIMENSIONS, ACCESSORIES, PHOTOMETRIC
L176
Test No. BAL12356
FLUORESCENT FIXTURE- LZ2N(S)40230
2’ – 2 40 Watt Biaxial
Lamp Type F40/2G11/835/RS
Lumens 3150 each
Total Bare Lamp
Lumens 6300
All data provided is for
F40/2G11/835/RS lamps
For LZ2N40130 1-lamp
models multiply x .50
For LZ2N55130
1-lamp models
multiply x .76
For LZ2N17230
multiply x .44
For LZ2N17330
multiply x .66
Efficiency 78.5%
90˚
80˚
70˚
60˚
50˚
40˚
30˚20˚10˚
180˚ 140˚ 120˚ 110˚
100˚
307
613
920
1226
90°
SPACING TO MOUNTING HEIGHT RATIO - 1.28 0-180°
SPACING TO MOUNTING HEIGHT RATIO - 1.88 90-270°
SPACING TO MOUNTING HEIGHT RATIO - 1.28 0-180°
SPACING TO MOUNTING HEIGHT RATIO - 1.88 90-270°
ZONAL LUMENS
ZONE LUMENS
0-30 826
0-40 1447
0-60 2977
0-90 4638
% EFFECTIVE
CEILING CAVITY
REFLECTAN
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .92 .92 .92 .92 .90 .90.90 .90 .84 .84 .84 .80.80 .80 .76 .76 .76 .74
1 .81 .76 .72 .68 .79 .74 .70 .66 .70 .66 .63 .66.63 .61 .62 .60 .58 .56
2 .73 .65 .58 .53 .70 .63.57 .52 .59 .54 .50 .56.52 .48 .53 .49 .46 .44
3 .65 .56 .48 .42 .63 .54.47 .42 .51 .45 .40 .48.43 .39 .45 .41 .37 .35
4 .59 .49 .41 .35 .57 .47.40 .34 .45 .38 .33 .42.37 .32 .40 .35 .31 .29
5 .54 .43 .35 .29 .52 .42.34 .29 .39 .33 .28 .37.32 .27 .35 .30 .26 .24
6 .50 .38 .30 .25 .48 .37.30 .25 .35 .29 .24 .33.28 .23 .32 .27 .23 .21
7 .46 .34 .27 .22 .44 .33.26 .21 .32 .25 .21 .30.25 .20 .29 .24 .20 .18
8 .43 .31 .24 .19 .41 .30 .24 .19 .29 .23 .18 .27.22 .18 .26 .21 .17 .16
9 .40 .28 .21 .17 .38 .28.21 .17 .26 .20 .16 .25.20 .16 .24 .19 .16 .14
10 .37 .26 .19 .15 .36 .25.19 .15 .24 .19 .15 .23.18 .14 .22 .17 .14 .12
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
VERT. ZONAL
ANGLE 0 22.5 45 67.5 90 LUMENS
0.0 948. 948. 948. 948. 948.
5.0 948. 951. 959. 958. 954. 91.20
10.0 937. 950. 977. 989. 989.
15.0 917. 944. 989. 1017. 1023. 277.80
20.0 889. 931. 1000. 1041. 1051.
25.0 855. 912. 1003. 1065. 1079. 456.80
30.0 809. 886. 1004. 1103. 1143.
35.0 757. 852. 1006. 1137. 1176. 622.10
40.0 698. 809. 1012. 1149. 1198.
45.0 635. 760. 1000. 1155. 1226. 744.40
50.0 559. 711. 981. 1175. 1206.
55.0 478. 667. 967. 1094. 1118. 791.00
60.0 395. 617. 896. 1002. 1069.
65.0 307. 552. 784. 928. 930. 715.20
70.0 224. 481. 707. 804. 834.
75.0 147. 383. 597. 712. 765. 568.30
80.0 88. 308. 520. 632. 670.
85.0 50. 236. 402. 472. 515. 379.80
90.0 19. 134. 244. 315. 341.
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
approx. 1-3/4“
(44.4)
1/4“ (20)
1/2“ (12)
1
*
*
*Mounting Centers are 1/4-20" tapped for
user all thread rod or below accessories.
1Dimensions in ( ) are millimeters.
2Product accessories have hardware for attachment
to fixture; hardware to attach to wall/ceiling F.B.O.
NOTE: Eyebolts are 316 Series, brackets are 300
Series Stainless Steel.
DIMENSIONS LZ2N, LZ2NE SERIES
Replacement Parts:
LZ2N4LENS 4' Lens only LZ2N/LZ2S
LZ2N2LENS 2' Lens only LZ2N/LZ2S
LZ2N4BAR 4' Locking Bar only LZ2N
LZ2N2BAR 2' Locking Bar only LZ2N
LZ2S-LATCH Latch and Spring
Mounting Accessories
For All LZ2N, LZ2S Series
Wall Bracket Set2
Part Number LZWB
Stainless Steel
(natural finish)
Adjustable
Wall Bracket Set2
Part Number LZAB
Stainless Steel bracket with ceramic
coated pivot bolt
Ceiling Bracket Set2
Part Number LZCB
Stainless Steel
(natural finish)
Eyebolt Set
Part Number LZEB
Stainless Steel bolt with lockwasher & nut
(natural finish)
Suspension Chains (2 required)
Part Number HFX-SC
36" length plated steel chain with snap link ends
For use with LZEB
LZ2N, LZ2S SERIES LIGHTING
PHOTOMETRIC DATA L177
L177
L
Test No. BAL 12357
FLUORESCENT FIXTURE- LZ2N(S)40430
4' – 4 40 Watt BIAXIAL Lumens 3150 each
Lamp Type F40/2G11/835/RS
Total Bare Lamp Lumens 12600
All data provided is for F40/2G11/835/RS lamps
Efficiency 76%
90˚
80˚
70˚
60˚
50˚
40˚
30˚20˚10˚
180˚ 140˚ 120˚ 110˚
100˚
631
1261
1892
2522
90°
SPACING TO MOUNTING HEIGHT RATIO - 1.28 0-180°
SPACING TO MOUNTING HEIGHT RATIO - 1.94 90-270°
ZONAL LUMENS
ZONE LUMENS
0-30 1649
0-40 2863
0-60 5876
0-90 8993
% EFFECTIVE
CEILING CAVITY
REFLECTAN
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .89 .89 .89 .89 .87 .87.87 .87 .82 .82 .82 .77.77 .77 .73 .73 .73 .71
1 .79 .74 .70 .66 .76 .72.68 .65 .68 .65 .62 .64.61 .59 .61 .58 .57 .54
2 .71 .63 .57 .52 .68 .61.56 .51 .58 .53 .49 .54.50 .47 .51 .48 .45 .43
3 .64 .54 .47 .41 .61 .53.46 .41 .50 .44 .39 .47.42 .38 .44 .40 .37 .35
4 .58 .47 .40 .34 .56 .46.39 .34 .44 .37 .33 .41.36 .32 .39 .34 .31 .29
5 .53 .42 .34 .29 .51 .41.34 .28 .39 .32 .28 .36.31 .27 .35 .30 .26 .24
6 .48 .37 .30 .25 .47 .36.29 .24 .34 .28 .24 .33.27 .23 .31 .26 .22 .21
7 .45 .34 .26 .21 .43 .33.26 .21 .31 .25 .21 .30.24 .20 .28 .23 .20 .18
8 .41 .30 .23 .19 .40 .30.23 .19 .28 .22 .18 .27.22 .18 .26 .21 .17 .16
9 .39 .28 .21 .17 .37 .27.21 .16 .26 .20 .16 .25.19 .16 .24 .19 .15 .14
10 .36 .25 .19 .15 .35 .25.19 .15 .24 .18 .14 .23.18 .14 .22 .17 .14 .12
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
VERT. ZONAL
ANGLE 0 22.5 45 67.5 90 LUMENS
0.0 1852. 1852. 1852. 1852. 1852.
5.0 1852. 1852. 1860. 1870. 1876. 177.7
10.0 1876. 1889. 1932. 1971. 1987.
15.0 1840. 1873. 1957. 2032. 2061. 553.6
20.0 1808. 1874. 2022. 2143. 2196.
25.0 1693. 1790. 1978. 2145. 2193. 909.1
30.0 1588. 1730. 1991. 2172. 2269.
35.0 1475. 1650. 1943. 2229. 2340. 1213.9
40.0 1350. 1571. 1959. 2256. 2345.
45.0 1267. 1564. 2083. 2385. 2522. 1534.8
50.0 1073. 1394. 1895. 2288. 2380.
55.0 912. 1280. 1854. 2176. 2247. 1545.2
60.0 730. 1149. 1673. 1938. 2013.
65.0 571. 1038. 1541. 1785. 1833. 1381.1
70.0 400. 885. 1342. 1549. 1558.
75.0 250. 698. 1075. 1321. 1433. 1040.9
80.0 132. 533. 968. 1208. 1262.
85.0 56. 397. 726. 921. 983. 699.6
90.0 28. 212. 464. 619. 665.
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
Test No. BAL 12359
FLUORESCENT FIXTURE- LZ2N(S)32330
4' – 3 32W F32WT8/835/RS LAMPS
2950 Lumens Each
Total Bare Lamp Lumens 8850
For 28 Watt T5 Multiply By .98
For 54 Watt T5 HO Multiply By 1.69
Efficiency 77.5%
90˚
80˚
70˚
60˚
50˚
40˚
30˚20˚10˚
180˚ 140˚ 120˚ 110˚
100˚
475
950
1899
90°
1424
SPACING TO MOUNTING HEIGHT RATIO - 1.26 0-180°
SPACING TO MOUNTING HEIGHT RATIO - 1.48 90-270°
ZONAL LUMENS
ZONE LUMENS
0-30 1482
0-40 2470
0-60 4651
0-90 6562
% EFFECTIVE
CEILING CAVITY
REFLECTAN
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .91 .91 .91 .91 .89 .89.89 .89 .84 .84 .84 .80.80 .80 .76 .76 .76 .74
1 .82 .78 .74 .70 .79 .75.72 .69 .71 .68 .66 .68.65 .63 .64 .62 .61 .59
2 .74 .67 .61 .56 .71 .65.59 .55 .61 .57 .53 .58.55 .51 .55 .52 .50 .48
3 .67 .58 .51 .45 .64 .56.50 .45 .53 .48 .44 .51.46 .42 .48 .44 .41 .39
4 .61 .51 .44 .38 .59 .50.43 .37 .47 .41 .37 .45.40 .36 .43 .38 .35 .33
5 .56 .45 .38 .32 .54 .44.37 .32 .42 .36 .31 .40.35 .31 .38 .34 .30 .28
6 .51 .40 .33 .28 .50 .40.33 .28 .38 .32 .27 .36.31 .27 .35 .30 .26 .24
7 .47 .37 .29 .24 .46 .36.29 .24 .34 .28 .24 .33.27 .23 .31 .27 .23 .21
8 .44 .33 .26 .22 .43 .33.26 .21 .31 .25 .21 .30.25 .21 .29 .24 .20 .19
9 .41 .30 .24 .19 .40 .30.23 .19 .29 .23 .19 .28.22 .19 .27 .22 .18 .17
10 .39 .28 .22 .17 .37 .27.21 .17 .26 .21 .17 .25.20 .17 .25 .20 .17 .15
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
VERT. ZONAL
ANGLE 0 22.5 45 67.5 90 LUMENS
0.0 1786. 1786. 1786. 1786. 1786.
5.0 1774. 1774. 1778. 1781. 1781. 169.6
10.0 1800. 183. 1819. 1834. 1840.
15.0 1751. 1761. 1794. 1822. 1834. 508.1
20.0 1745. 1771. 1827. 1879. 1899.
25.0 1609. 1644. 1724. 1790. 1814. 794.9
30.0 1517. 1571. 1679. 1748. 1784.
35.0 1391. 1458. 1590. 1684. 1714. 986.9
40.0 1272. 1364. 1520. 1632. 1674.
45.0 1194. 1315. 1507. 1643. 1687. 1143.4
50.0 1010. 1150. 1353. 1491. 1551.
55.0 856. 1014. 1248. 1402. 1420. 1077.2
60.0 685. 857. 1124. 1215. 1245.
65.0 534. 741. 978. 1092. 1121. 902.9
70.0 372. 610. 830. 956. 990.
75.0 229. 452. 671. 779. 824. 642.3
80.0 116. 340. 531. 617. 650.
85.0 53. 213. 356. 453. 489. 352.6
90.0 16. 108. 245. 342. 378.
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
Test No. BAL 12358
FLUORESCENT FIXTURE- LZ2N(S)32230
4' – 2 32W F32WT8/835/RS LAMPS
2950 Lumens Each
Total Bare Lamp Lumens 5900
For 28 Watt T5 Multiply By .98
For 34/40 Watt T12 Multiply By 1.07
For 44 Watt T8 Multiply By 1.36
For 54 Watt T5 Multiply By 1.69
For 60 Watt T12 Multiply By 1.46
Efficiency 80.9%
90˚
80˚
70˚
60˚
50˚
40˚
30˚20˚10˚
180˚ 140˚ 120˚ 110˚
100˚
306
611
1222
90°
917
SPACING TO MOUNTING HEIGHT RATIO - 1.26 0-180°
SPACING TO MOUNTING HEIGHT RATIO - 1.56 90-270°
ZONAL LUMENS
ZONE LUMENS
0-30 957
0-40 1608
0-60 3077
0-90 4521
% EFFECTIVE
CEILING CAVITY
REFLECTAN
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .95 .95 .95 .95 .93 .93.93 .93 .88 .88 .88 .83.83 .83 .79 .79 .79 .77
1 .85 .80 .76 .72 .82 .78.74 .70 .73 .70 .67 .69.67 .64 .66 .64 .62 .60
2 .76 .68 .62 .57 .73 .66.61 .56 .63 .58 .54 .59.55 .52 .56 .53 .50 .48
3 .69 .59 .52 .46 .66 .58.51 .45 .54 .49 .44 .52.47 .42 .49 .45 .41 .39
4 .63 .52 .44 .38 .60 .51.43 .38 .48 .42 .37 .45.40 .36 .43 .39 .35 .33
5 .57 .46 .38 .32 .55 .45.37 .32 .43 .36 .31 .40.35 .30 .39 .34 .30 .28
6 .53 .41 .33 .28 .51 .40.33 .28 .38 .32 .27 .36.31 .26 .35 .30 .26 .24
7 .49 .37 .30 .24 .47 .36.29 .24 .35 .28 .24 .33.27 .23 .32 .27 .23 .21
8 .45 .34 .27 .22 .44 .33.26 .21 .32 .25 .21 .30.25 .21 .29 .24 .20 .18
9 .42 .31 .24 .19 .41 .30.24 .19 .29 .23 .19 .28.22 .18 .27 .22 .18 .16
10 .40 .28 .22 .17 .38 .28.21 .17 .27 .21 .17 .26.20 .17 .25 .20 .16 .15
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
VERT. ZONAL
ANGLE 0 22.5 45 67.5 90 LUMENS
0.0 1145. 1145. 1145. 1145. 1145.
5.0 1143. 1143. 1141. 1143. 1144. 109.1
10.0 1154. 1154. 1163. 1176. 1182.
15.0 1141. 1143. 1169. 1192. 1204. 331.4
20.0 1104. 1116. 1162. 1206. 1222.
25.0 1035. 1057. 1122. 1175. 1190. 516.8
30.0 971. 1008. 1096. 1146. 1182.
35.0 900. 949. 1035. 1134. 1166. 651.9
40.0 812. 881. 1005. 1100. 1138.
45.0 755. 849. 1003. 1109. 1150. 757.7
50.0 636. 739. 909. 1037. 1097.
55.0 538. 650. 845. 994. 1033. 734.4
60.0 432. 573. 771. 878. 928.
65.0 333. 488. 686. 792. 846. 634.2
70.0 230. 397. 595. 771. 817.
75.0 140. 302. 544. 638. 683. 501.3
80.0 71. 233. 437. 523. 557.
85.0 32. 170. 303. 397. 434. 300.9
90.0 11. 88. 205. 294. 330.
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
HFX-T SERIES LIGHTING
BIAXIAL (LONG TWIN TUBE)
L178
L178
FEATURES-SPECIFICATIONS
Listed - File E12976 and E89665 (Marine)
Certified - File LR11713
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4X, 7(C,D) 9(E,F,G)
Suitable for wet locations
Suitable for paint spray booths
2’ Nominal
Style
4’ Nominal
Style
Applications
Biaxial single ended lamp type HFX-T fix-
tures provide greater efficiency and
lumen output than standard models.
Designed for installations where moisture,
dirt, dust, corrosion and vibration may be
present, or NEMA 3 and 4X areas where
wind, water and snow can be expected.
They can also be used in locations made
hazardous due to the presence of flam-
mable or explosive gases, vapors and
combustible ducts as defined by the
NEC.
Typical applications include classified
areas such as inside paint spray booths,
paint manufacturing plants, ammunition
facilities, oil and gas producing and
refining plants, off-shore and dockside
installations, tank farms, pipeline pump-
ing stations and marine loading and fuel
transfer terminals.
Features
UL Listed and labeled for use inside
paint spray booths and rooms
2’ nominal compact models facilitate
use in areas too small for nominal 4’
models, or where the light must be
confined
Standard ballast is 120-277V
at 50/60 Hz1
0°F starting temperature
Construction is strong lightweight corro-
sion resistant copper-free aluminum alloy,
less than 4/10 of 1%
All external hardware is corrosion resis-
tant 316 stainless steel
UL Listed externally fused ballast option;
protects fixture on line side of ballast,
prevents ballast burnout
Suitable for use in both indoor and
outdoor wet locations
Relamping easily accomplished by
removing screw in cap and socket
Factory sealed construction
Extruded aluminum reflectors are easily
removable for cleaning. White baked
enamel finish
Compliances
UL-1570, Standard for Fluorescent
Lighting Fixtures
UL Marine Type Lighting Fixtures
UL-844, Standard for Lighting Fixtures
for Hazardous Locations
CSA C22.2 137-M1981
Meets requirements of NFPA 70-1987
Article 516 and NFPA standard 33
Catalog Number Logic
Constant for HFX Series
Lamp Wattage
40—40 Watt BIAXIAL Type
55—55 Watt BIAXIAL Type
2 lamps (2’ Nominal)
4 lamps (4’ Nominal)
Voltage
30—120-277V 50/60 Hz.
HFX - 00 T - 00 - 0 - F
F1 Fuse 120V
F2 Fuse 277V
RATE D SUITABLE CLASS I, DIV, 1 & 2 CLASS II, DIV, 1 & 2 CLASS III UL PAINT NEMA
DESCRIPTION AMBIENT FOR °C MAX. SURFACE TEMP. MAX. SURFACE TEMP. DIV. 1 & 2 S PRAY
°C SUPPLY WIRE TEMP. T-CODE GROUPS TEMP. T-CODE GROUPS SUITABILITY MARINE SUITABLE 3 & 4 X
HFX-T 40W 2 LAMP 40 60 85°C T6 C, D 12C T4A E, F, G Yes Yes Yes Yes
HFX-T 55W 2 LAMP 40 60 85°C T6 C, D 12C T4A E, F, G Yes Yes Yes Yes
HFX-T 40W 4 LAMP 40 60 85°C T6 C, D 12C T4A E, F, G Yes Yes Yes Yes
HFX-T 55W 4 LAMP 40 60 85°C T6 C, D 12C T4A E, F, G Yes Yes Yes Yes
HFX-T, HFXE-T HAZARDOUS LOCATION APPLICATION DATA
CONDUIT LINE VOLTAGE DESCRIPTION PROFILE
SIZE
HFX-40T-302 2’ 2 Lamp 40W BIAXIAL T5
HFX-55T-302 3⁄4" 120V-277V 2’ 2 Lamp 55W BIAXIAL T5
HFX-40T-304 50/60 Hz 4’ 4 Lamp 40W BIAXIAL T5
HFX-55T-304 4’ 4 Lamp 55W BIAXIAL T5
HFX-T BIAXIAL TYPE LIGHT FIXTURES12
Two Glass Tubes
2’ or 4’ Nominal
1See page L182 for ballast current information.
2Consult HFX page L183 for dimensions and accessories. Photometrics on following page.
CATALOG
NUMBER
SEE PAGE L210
FOR HFXE
EMERGENCY MODELS
HFX-T SERIES LIGHTING
BIAXIAL LONG TWIN TUBE ACCESSORIES, PHOTOMETRIC DATA L179
L179
L
Test No. BAL12360
FLUORESCENT FIXTURE-
HFX-40T-302
Lamp Type F40/2G11/835/RS
2' – 2 40 Watt Biaxial 3150 Lumens each.
Total Bare Lamp Lumens 6300
For 55W Biaxial multiply by 1.52.
Efficiency 83.2%
90˚
80˚
70˚
60˚
50˚
40˚
30˚20˚10˚
180˚ 140˚ 120˚ 110˚
100˚
90˚
386
772
1158
1544
SPACING TO MOUNTING HEIGHT RATIO - 1.28 0-180°
SPACING TO MOUNTING HEIGHT RATIO - 1.50 90-270°
Test No. BAL12361
ZONAL LUMENS
ZONE LUMENS
0-30 1246
0-40 2102
0-60 3989
0-90 5237
% EFFECTIVE
CEILING CAVITY
REFLECTAN
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .99 .99 .99 .99 .97 .97.97 .97 .92 .92 .92 .88.88 .88 .85 .85 .85 .83
1 .90 .86 .82 .79 .88 .84.81 .78 .80 .78 .75 .77.75 .73 .74 .72 .71 .69
2 .81 .74 .68 .63 .79 .73.67 .63 .70 .65 .61 .67.63 .60 .64 .61 .58 .56
3 .74 .65 .58 .52 .72 .63.57 .51 .61 .55 .50 .58.54 .50 .56 .52 .49 .47
4 .67 .57 .49 .43 .65 .56.49 .43 .54 .47 .42 .52.46 .42 .50 .45 .41 .39
5 .62 .50 .43 .37 .60 .50.42 .37 .48 .41 .36 .46.40 .36 .44 .39 .35 .34
6 .57 .45 .37 .32 .55 .44.37 .32 .43 .36 .31 .41.36 .31 .40 .35 .31 .29
7 .52 .41 .33 .28 .51 .40.33 .28 .39 .32 .28 .38.32 .27 .36 .31 .27 .25
8 .49 .37 .30 .25 .47 .36.30 .25 .35 .29 .24 .34.29 .24 .33 .28 .24 .23
9 .45 .34 .27 .22 .44 .33.27 .22 .32 .26 .22 .32.26 .22 .31 .25 .22 .20
10 .43 .31 .24 .20 .41 .31.24 .20 .30 .24 .20 .29.24 .20 .28 .23 .20 .18
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
VERT. ZONAL
ANGLE 0 22.5 45 67.5 90 LUMENS
01530. 1530. 1530. 1530. 1530.
5.0 1533. 1524. 1520. 1533. 1531. 145.8
10.0 1515. 1509. 1515. 1527. 1536.
15.0 1484. 1486. 1508. 1531. 1544. 428.0
20.0 1435. 1453. 1492. 1526. 1543.
25.0 1379. 1410. 1464. 1511. 1540. 676.4
30.0 1310. 1355. 1427. 1485. 1530.
35.0 1227. 1286. 1377. 1448. 1490. 858.9
40.0 1132. 1209. 1313. 1403. 1440.
45.0 1026. 1123. 1242. 1354. 1389. 953.7
50.0 913. 1024. 1168. 1287. 1326.
55.0 783. 902. 1083. 1205. 1236. 941.8
60.0 649. 781. 982. 1094. 1090.
65.0 507. 667. 862. 875. 857. 765.8
70.0 346. 543. 641. 601. 600.
75.0 197. 396. 408. 425. 428. 407.7
80.0 72. 218. 224. 242. 240.
85.0 14. 74. 56. 52. 51. 58.8
90.0 1. 10. 6. 7. 8.
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
FLUORESCENT FIXTURE-
HFX-40T-304
Lamp Type F40/2G11/835/RS
4' – 4 40 Watt Biaxial 3150 Lumens each.
Total Bare Lamp Lumens 12600
For 55W Biaxial multiply by 1.52.
Efficiency 76%
90˚
80˚
70˚
60˚
50˚
40˚
30˚20˚10˚
180˚ 140˚ 120˚ 110˚
100˚
90˚
698
1397
2095
2793
SPACING TO MOUNTING HEIGHT RATIO - 1.28 0-180°
SPACING TO MOUNTING HEIGHT RATIO - 1.52 90-270°
ZONAL LUMENS
ZONE LUMENS
0-30 2197
0-40 3685
0-60 7050
0-90 9559
% EFFECTIVE
CEILING CAVITY
REFLECTAN
1cc
80 70 50 30 10 0
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
20% Effective Floor Cavity Reflectance
0 .90 .90 .90 .90 .88 .88.88 .88 .84 .84 .84 .81.81 .81 .77 .77 .77 .76
1 .82 .78 .74 .71 .80 .76 .73 .70 .73 .70 .68 .70.68 .65 .67 .65 .63 .62
2 .74 .67 .61 .57 .72 .66.60 .56 .63 .58 .55 .60.56 .53 .58 .55 .52 .50
3 .67 .58 .52 .46 .65 .57.51 .46 .55 .49 .45 .52.48 .44 .50 .47 .43 .42
4 .61 .51 .44 .39 .59 .50.43 .38 .48 .42 .38 .46.41 .37 .45 .40 .37 .35
5 .56 .45 .38 .33 .54 .44.38 .33 .43 .37 .32 .41.36 .32 .40 .35 .31 .30
6 .51 .41 .33 .28 .50 .40.33 .28 .38 .32 .28 .37.32 .28 .36 .31 .27 .26
7 .47 .37 .30 .25 .46 .36.29 .25 .35 .29 .24 .34.28 .24 .33 .28 .24 .22
8 .44 .33 .27 .22 .43 .33.26 .22 .32 .26 .22 .31.25 .22 .30 .25 .21 .20
9 .41 .30 .24 .20 .40 .30.24 .20 .29 .23 .19 .28.23 .19 .27 .23 .19 .18
10 .38 .28 .22 .18 .37 .28.22 .18 .27 .21 .17 .26.21 .17 .25 .21 .17 .16
% WALL
REFLECTANCE
1w
ROOM CAVITY
RATIO
RCR
VERT. ZONAL
ANGLE 0 22.5 45 67.5 90 LUMENS
0.0 2625 2625 2625 2625 2625
5.0 2606 2607 2611 2617 2620 249.3
10.0 2661 2669 2692 2716 2726
15.0 2621 2641 2693 2738 2756 762.6
20.0 2559 2597 2692 2766 2793
25.0 2393 2450 2564 2653 2685 1181.0
30.0 2254 2335 2477 2590 2635
35.0 2102 2207 2381 2528 2587 1485.7
40.0 1959 2094 2306 2502 2571
45.0 1778 1951 2236 2473 2544 1707.9
50.0 1609 1793 2106 2325 2387
55.0 1404 1612 1966 2169 2234 1697.1
60.0 1140 1369 1701 1890 1942
65.0 928 1202 1542 1680 1698 1423.7
70.0 676 984 1268 1290 1277
75.0 425 735 871 860 889 825.8
80.0 204 473 548 623 643
85.0 58 202 256 248 251 234.9
90.0 15 36 44 53 60
COEFFICIENTS OF UTILIZATION ---ZONAL CAVITY METHOD
CATALOG
NUMBER DESCRIPTION
2HFX-G2 302 HFX-T Models
2HFX-G4 304 HFX-T Models
WIRE GUARD1
1316 Stainless Steel
Consult page L183 for dimensions
and accessories.
SEE PAGE L210
FOR HFXE
EMERGENCY MODELS
2’ Nominal
Style
4’ Nominal
Style
HFX SERIES LIGHTING
FLUORESCENT FIXTURES
L180
L180
FEATURES-SPECIFICATIONS
Listed - File E12976 and E89665 (Marine)
Class I, Div. 1 & 2 Groups C,D
Class l, Zones 1 & 2, Groups llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4X, 7(C,D) 9(E,F,G)
Suitable for wet locations
Suitable for paint spray booths
Certified - File LR11713
Applications
HFX Series fluorescent fixtures are
designed for installations where moisture,
dirt, dust, corrosion and vibration may be
present, or NEMA 3 and 4X areas where
wind, water and snow can be expected.
They can also be used in locations made
hazardous due to the presence of flam-
mable or explosive gases, vapors and
combustible ducts as defined by the NEC.
Typical applications include classified
areas such as inside paint spray booths,
paint manufacturing plants, ammunition
facilities, oil and gas producing and
refining plants, off-shore and dockside
installations, tank farms, pipeline pump-
ing stations and marine loading and fuel
transfer terminals.
Features
UL Listed and labeled for use inside
paint spray booths and rooms
Construction is strong lightweight corro-
sion resistant copper-free aluminum
alloy, less than 4/10 of 1%
Class P ballast(s) with internal automat-
ic thermally activated protective device
All external hardware is corrosion
resistant 316 stainless steel to provide
maintenance free long life
UL factory sealed construction (no
external seals required). Saves installa-
tion time and cost
Electronic energy efficient ballasts
are standard on 430 MA fixtures and
meet the requirements of many states
Extruded aluminum reflectors are easily
removable for cleaning. White baked
enamel finish
Optional 316 stainless steel wire guard for
added protection
Threaded O-Ring gasketed covers
provide easy access to lamp chambers,
ballast and wiring compartment
UL Listed externally fused ballast option;
protects fixture on line side of ballast,
prevents ballast burnout
Suitable for use in both indoor and
outdoor wet locations
Relamping from either end permits easy
access, speed and flexibility in relamping
Catalog Number Logic
Constant for HFX Series
Lamp Current
265—265 MA, 32W T8 (0°F Starting,
Electronic)
430—430 MA, 40W RS (50°F Starting
Electronic)2
800—800 MA, 60W RS HO
(-20°F Starting)
1500—1500 MA, 110W RS VHO
(-20°F Starting)
Voltage
1—120V, 60 Hz.
4—277, 60 Hz.
7—220V, 60 Hz. 430 MA
8—220/240V, 50 Hz., 430 MA
(2 and 4 lamp models only)
30—120-277V 50/60 Hz 265 MA only.
Options
FB—Individually in-line fused
ballast (not Marine or CSA)
WL—With lamps supplied
Number of Lamps
2—2 lamps
3—3 lamps
4—4 lamps
HFX - 000 - 00 - 00
Spring loaded sockets on both lamp
ends provide positive electrical contact
and improved vibration resistance
Compliances
UL-1570, Standard for Fluorescent
Lighting Fixtures
UL Marine Type Lighting Fixtures
UL-844, Standard for Lighting Fixtures
for Hazardous Locations
CSA C22.2 137-M1981
Meets requirements of NFPA 70-1987
Article 516 and NFPA standard 33
FIXTURE LAMP RATED SUITABLE CLASS I, DIV, 1 & 2 CLASS II, DIV, 1 & 2 CLASS III UL PAINT NEMA
AMBIENT FOR °C MAX. SURFACE TEMP. MAX. SURFACE TEMP. DIV. 1 & 2 S PRAY
SERIES WATTS °C SUPPLY WIRE TEMP. T-CODE GROUPS TEMP. T-CODE GROUPS SUITABILITY MARINE SUITABLE 3&4
HFX 32 40 90 100°C T5 C, D 12C T4A E, F, G Yes Yes Yes Yes
HFX 40 40 90 100°C T5 C, D 12C T4A E, F, G Yes Yes Yes Yes
HFX 60 40 90 100°C T5 C, D 12C T4A E, F, G Yes Yes Yes Yes
HFX 110 40 90 10C T5 C, D 120°C T4A E, F, G Yes Yes Yes Yes
HFX, HFXE HAZARDOUS LOCATION APPLICATION DATA1
1Ratings apply to all 2, 3, and 4 lamp models.
2430 MA ballasts 6F start with 34 watt lamps.
SEE PAGE L210
FOR HFXE
EMERGENCY MODELS
HFX SERIES LIGHTING
FLUORESCENT FIXTURES L181
L181
FEATURES-SPECIFICATIONS
L
Listed - File E12976 and E89665 (Marine)
Certified - File LR11713
Class I, Div. 1 & 2 Groups C,D
Class l, Zones 1 & 2, Groups llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4X, 7(C,D) 9(E,F,G)
Suitable for wet locations
Suitable for paint spray booths
CONDUIT LINE VOLTAGE DESCRIPTION NUMBER
SIZE @60 HERTZ OF LAMPS
HFX-265-302 120V-277V 50/60 Hz 32W T8 electronic ballast 265MA
HFX-430-12 120V 40W rapid start electronic F40T12
HFX-430-42 3/4" 277V medium Bi-Pin 430MA
HFX-800-12 120V 60W rapid start high output F48T12/HO
HFX-800-42 277V recessed double contact 800MA
HFX-1500-12 120V 110W rapid start VHO F48T12/VHO
HFX-1500-42 277V recessed double contact 1500MA
HFX-265-303 120V-277V 50/60 Hz 32W T8 electronic ballast 265MA
HFX-430-13 120V 40W rapid start electronic F40T12
HFX-430-43 277V medium Bi-Pin 430MA
HFX-800-13 3/4" 120V 60W rapid start high output F48T12/HO
HFX-800-43 277V recessed double contact 800MA
HFX-1500-13 120V 110w rapid start VHO F48T12/VHO
HFX-1500-43 277V recessed double contact 1500MA
HFX-265-304 120V-277V 50/60 Hz 32W T8 electronic ballast 265MA
HFX-430-14 120V 40W rapid start electronic F40T12
HFX-430-44 277V medium Bi-Pin 430MA
HFX-800-14 3/4" 120V 60W rapid start high output F48T12/HO
HFX-800-44 277V recessed double contact 800MA
HFX-1500-14 120V 110W rapid start VHO F48T12/VHO
HFX-1500-44 277V recessed double contact 1500MA
HFX FLUORESCENT LIGHT FIXTURES
Two Glass Tubes
4’ Nominal
Three Glass Tubes
4’ Nominal
1Standard ballasts starting temperatures:
32 Watt (265MA) Electronic 0°F
40 Watt (430MA) Electronic 50°F, 60°F with 34 Watt lamps
60 Watt (800MA) Electronic -20°F
110 Watt (1500MA) Electronic -20°F
Optional cold weather electromagnetic ballast (0°F starting 40 Watt 430MA) add suffix CW to catalog number.
2Optional UL listed in-line ballast fusing is available by adding suffix FB to catalog number (UL only).
3Safety chain accessory catalog number HFX-SC available, supplied standard with 4 lamp fixtures.
Four Glass Tubes
4’ Nominal
3
CATALOG NUMBER1 2
CATALOG DESCRIPTION
NUMBER
2HFX-G4 2-Lamp 316 grade stainless steel
3HFX-G4 3-Lamp 316 grade stainless steel
WIRE GUARD
4 lamp fixture requires two 2HFX-G4 guards.
SEE PAGE L210
FOR HFXE
EMERGENCY MODELS
HFX(T) SERIES LIGHTING
BALLAST DATA
L182
L182
FEATURES-SPECIFICATIONS
Listed - File E12976 and E89665 (Marine)
Certified - File LR11713
Class I, Div. 1 & 2 Groups C,D
Class l, Zones 1 & 2, Groups llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 4X, 7(C,D) 9(E,F,G)
Suitable for wet locations
Suitable for paint spray booths
CATALOG NO. OF LINE CURRENT INPUT STARTING
NUMBER LAMPS VOLTAGE AMPS WATTS TEMPERATURE
32 WATT T-8 ELECTRONIC 48" 265MA
HFX-265-302 2 120-277 .54 (120V) 71 0°F (-18°C)
.24 (277V)
HFX-265-30313 120-277 .71 (120V) 88 0°F (-18°C)
.31 (277V)
HFX-265-304 4 120-277 1.10 (120V) 142 0°F (-18°C)
.48 (277V)
40 WATT RAPID START ELECTRONIC T-12 MEDIUM BI-PIN 48" 430MA
HFX-430-12 2 120 .51260 60°F (16°C)
HFX-430-42 2 277 .22260 60°F (16°C)
HFX-430-1313 120 .69291 60°F (16°C)
HFX-430-4313 277 .30291 60°F (16°C)
HFX-430-14 4 120 1.022120 60°F (16°C)
HFX-430-44 4 277 .442120 60°F (16°C)
40 WATT BIAXIAL TYPE
HFX-40T-302 2120-277 .63 (120V) 76 0°F (-18°C)
50/60 Hz .27 (277V)
HFX-40T-304 4120-277 1.32 (120V) 156 0°F (-18°C)
50/60 Hz .54 (277V)
55 WATT BIAXIAL TYPE
HFX-55T-302 2120-277 .94 (120V) 112 -20°F (-29°C)
50/60 Hz .41 (277V)
HFX-55T-304 4120-277 1.97 (120V) 232 -20°F (-29°C)
50/60 Hz .84 (277V)
60 WATT RAPID START HIGH OUTPUT T-12 RECESSED DOUBLE CONTACT 48" 800MA
HFX-800-12 2 120 1.40 135 -20°F (-29°C)
HFX-800-42 2 277 .61 145 -20°F (-29°C)
HFX-800-13 3 120 2.40 260 -20°F (-29°C)
HFX-800-43 3 277 1.03 235 -20°F (-29°C)
HFX-800-14 4 120 2.80 270 -20°F (-29°C)
HFX-800-44 4 277 1.22 290 -20°F (-29°C)
110 WATT RAPID START VERY HIGH OUTPUT T-12 RECESSED DOUBLE CONTACT 48" 1500MA
HFX-1500-12 2 120 2.10 242 -20°F (-29°C)
HFX-1500-42 2 277 .92 242 -20°F (-29°C)
HFX-1500-13 3 120 3.38 376 -20°F (-29°C)
HFX-1500-43 3 277 1.48 377 -20°F (-29°C)
HFX-1500-14 4 120 4.20 484 -20°F (-29°C)
HFX-1500-44 4 277 1.84 484 -20°F (-29°C)
HFX BALLAST DATA
13 lamp 265MA and 430MA fixtures use a single ballast.
2Line current and 60°F start using 34 Watt lamps. Start temperature for
40 Watt lamps is 50°F (10°C). 40 Watt lamps current approximately
24% higher.
HFX(T) SERIES LIGHTING
BALLAST DATA L183
L183
L
Typical installation using conduit hardware.
Dummy (non-powered) end lowers for
relamping clearance, which is required
when fixtures are mounted in close
proximity. Flexible mounting provides
free swing and impact protection.
1. Splice Box/Fixture Hanger (HXB)
2. Flexible Pendant Hanger (EKJ)
3. Union (GUM)
4. Rigid Support Saddle Bracket (KFHS)
5. Support Hook (KEFHM)
Note: Leave extra links to support
fixture in relamping position. Chain
furnished by others.
Dummy (non-powered) end lowers for
relamping clearance, which is required
when fixtures are mounted in close
proximity.
1. Splice Box/Fixture Hanger (XFH)
2. Swivel Hanger (KESD)
3. Union (GUM)
4. Rigid Support Saddle Bracket (KFHS)
5. Support Hook (KEFHM)
6. 3/4" Rigid Threaded Nipple
Note: Leave extra links to support
fixture in relamping position. Chain
furnished by others.
Rigid mounted—for installations where
relamping can be accomplished without
lowering dummy end.
1. Splice Box/Fixture Hanger (HXB)
2. Union (GUM)
3. Rigid Support Saddle Bracket (KFHS)
For wall mounting, use securely fas-
tened 3/4" pipe 6" or less in length.
Floor flange (furnished by others)
recommended for dummy end as well
as chain or cable providing vertical
strain relief from above fixture. Chain
furnished by others.
CATALOG
NUMBER HUB SIZE DESCRIPTION
XFH-22 3/4" XFH SERIES
Splice box/fixture hanger
KESD SERIES
KESD-75 3/4" Swivel Hanger
15° swivel drop from center and full 360° free swing
KFHS SERIES
KFHS-5075 3/4" Rigid support saddle bracket for fluorescent fixtures (dummy end)
Will support 350 lbs. and straddle Max. 1-1⁄4" conduit
KEFHM SERIES
KEFHM-75 3/4" Safety support hook with 3/4" male end For dummy end of fixture
Will support 200 lbs. screw closed 3/8" jaw opening
HFX-SC HFX SERIES
Safety chain (36" length plated steel), standard on 4-tube fixture
MOUNTING HARDWARE
CATALOG HUB
NUMBER SIZE LENGTH DESCRIPTION
HXB-12 1/2" —
HXB-22 3/4" —
EKJ-24 3/4" 4
EKJ-26 3/4" 6
EKJ-28 3/4" 8
EKJ-210 3/4" 10
EKJ-212 3/4" 12
EKJ-215 3/4" 15
EKJ-218 3/4" 18
GUM-2 3/4"
MOUNTING HARDWARE
EKJ SERIES
Flexible
Pendant
Hanger
GU SERIES
Male Union
HXB SERIES
Splice Box/
3/4" Fixture
Hanger
HFX MODEL CONDUIT DIMENSIONS NET
SIZE ABCDE
WEIGHT
Nominal 2’ 2 Tubes 3/4-14 NPT 28-15/16" (735) 24-3/8" (619) 9-3/32" (231) 9-3/32" (231) 11" (279) 36.0 Lbs.
Nominal 4’ 2 Tubes 3/4-14 NPT 52-13/16" (1367) 48-3/8" (1229) 9-3/32" (231) 9-3/32" (231) 11" (279) 47.7 Lbs.
Nominal 4’ 3 Tubes 3/4-14 NPT 52-13/16" (1367) 48-3/8" (1229) 9-3/32" (231) 9-3/32" (231) 15-5/8" (397) 63.0 Lbs.
Nominal 4’ 4 Tubes 3/4-14 NPT 52-13/16" (1367) 48-3/8" (1229) 9-3/32" (231) 10-1/8" (257) 23" (584) 99.9 Lbs.
HFX DIMENSIONS
HFX SERIES LIGHTING
PHOTOMETRIC DATA/CANDLEPOWER DISTRIBUTION
L184
L184
VERTICAL HORIZONTAL ANGLE
ANGLE 0 22.5 45 67.5 90 ZONAL LUMENS
0.0 1325. 1325. 1325. 1325. 1325.
5.0 1359. 1366. 1366. 1369. 1365. 130
10.0 1313. 1321. 1328. 1338. 1325.
15.0 1309. 1315. 1323. 1333. 1333. 375
20.0 1288. 1302. 1318. 1331. 1333.
25.0 1196. 1213. 1238. 1252. 1259. 571
30.0 1147. 1169. 1198. 1229. 1236.
35.0 1037. 1065. 1104. 1145. 1160. 693
40.0 961. 1000. 1047. 1105. 1126.
45.0 819. 857. 921. 990. 1019. 714
50.0 737. 784. 867. 950. 982.
55.0 634. 690. 796. 899. 937. 711
60.0 518. 584. 711. 821. 836.
65.0 412. 498. 645. 693. 699. 594
70.0 263. 363. 465. 485. 487.
75.0 172. 281. 326. 339. 343. 318
80.0 80. 168. 189. 215. 223.
85.0 25. 75. 89. 89. 84. 84
90.0 6. 11. 14. 20. 22.
CANDLEPOWER 2-40/T12 RAPID START
VERTICAL HORIZONTAL ANGLE
ANGLE 0 22.5 45 67.5 90 ZONAL LUMENS
0.0 1971. 1971. 1971. 1971. 1971.
5.0 1988. 1985. 1987. 1994. 1990. 190
10.0 1946. 1949. 1953. 1960. 1962.
15.0 1929. 1934. 1944. 1959. 1963. 552
20.0 1897. 1907. 1926. 1947. 1961.
25.0 1773. 1788. 1817. 1850. 1866. 842
30.0 1688. 1713. 1758. 1802. 1819.
35.0 1551. 1580. 1640. 1701. 1722. 1030
40.0 1427. 1467. 1545. 1626. 1661.
45.0 1232. 1281. 1376. 1487. 1528. 1070
50.0 1101. 1159. 1284. 1417. 1463.
55.0 952. 1027. 1188. 1340. 1395. 1061
60.0 780. 871. 1068. 1233. 1254.
65.0 620. 735. 961. 1042. 1049. 887
70.0 403. 540. 706. 739. 742.
75.0 247. 414. 486. 512. 520. 475
80.0 120. 253. 290. 323. 323.
85.0 30. 93. 92. 84. 81. 89
90.0 3. 9. 12. 19. 19.
CANDLEPOWER 3-40/T12 RAPID START
VERTICAL HORIZONTAL ANGLE
ANGLE 0 22.5 45 67.5 90 ZONAL LUMENS
0.0 2650. 2650. 2650. 2650. 2650.
5.0 2718. 2733. 2733. 2738. 2730. 261
10.0 2627. 2641. 2656. 2677. 2650.
15.0 2617. 2630. 2646. 2665. 2665. 750
20.0 2577. 2604. 2635. 2663. 2666.
25.0 2393. 2427. 2476. 2504. 2518. 1141
30.0 2294. 2338. 2396. 2458. 2472.
35.0 2074. 2131. 2207. 2290. 2321. 1386
40.0 1922. 2000. 2095. 2209. 2252.
45.0 1637. 1713. 1843. 1980. 2037. 1427
50.0 1474. 1567. 1734. 1901. 1963.
55.0 1269. 1381. 1592. 1798. 1874. 1422
60.0 1035. 1168. 1422. 1643. 1672.
65.0 823. 997. 1291. 1386. 1398. 1187
70.0 526. 726. 929. 970. 973.
75.0 343. 562. 652. 678. 686. 636
80.0 159. 336. 378. 431. 446.
85.0 50. 149. 177. 177. 168. 167
90.0 13. 22. 28. 41. 44.
CANDLEPOWER 4-40/T12 RAPID START
Total Bare Lamp
Lumens 6400
All data provided is for
F40T12RS/WW lamps 40W
rapid start warm white. For
Candlepower/Lumen multipliers
of other lamps use the follow-
ing:
32W T8 (2850 lumen lamp) .89
34W T12 (2700 lumen lamp) .84
60W F48T12/WW/HO Warm
White High Output 1.35
110W F48T12/WW/VHO Warm
White Very High Output 1.97
ZONAL LUMENS
ZONE LUMENS
0-30 1076
0-40 1769
0-60 3194
0-90 4189
Total Bare Lamp
Lumens 9600
All data provided is for
F40T12RS/WW lamps 40W
rapid start warm white. For
Candlepower/Lumen multipliers
of other lamps use the follow-
ing:
32W T8 (2850 lumen lamp) .89
34W T12 (2700 lumen lamp) .84
60W F48T12/WW/HO Warm
White High Output 1.35
110W F48T12/WW/VHO Warm
White Very High Output 1.97
ZONAL LUMENS
ZONE LUMENS
0-30 1583
0-40 2613
0-60 4743
0-90 6194
Total Bare Lamp
Lumens 12800
All data provided is for
F40T12RS/WW lamps 40W
rapid start warm white. For
Candlepower/Lumen multipliers
of other lamps use the follow-
ing:
32W T8 (2850 lumen lamp) .89
34W T12 (2700 lumen lamp) .84
60W F48T12/WW/HO Warm
White High Output 1.35
110W F48T12/WW/VHO Warm
White Very High Output 1.97
ZONAL LUMENS
ZONE LUMENS
0-30 2152
0-40 3538
0-60 6388
0-90 8379
HFX SERIES LIGHTING
PHOTOMETRIC DATA/COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD FLUORESCENT FIXTURES
L185
L185
L
% EFFECTIVE CEILING 20% EFFECTIVE FLOOR CAVITY REFLECTANCE
CAVITY REFLECTANCE rcc .80 .70 .50 .30 .10 .00
% WALL REFLECTANCE rw .70 .50 .30 .10 .70 .50 .30 .10 .50 .30 .10 .50 .30 .10 .50 .30 .10 .00
0 .77 .77 .77 .77 .75 .75 .75 .75 .72 .72 .72 .69 .69 .69 .66 .66 .66 .65
1 .71 .68 .65 .63 .69 .66 .64 .62 .63 .61 .60 .61 .59 .58 .59 .57 .56 .55
2 .64 .59 .55 .51 .63 .58 .54 .51 .56 .52 .49 .54 .51 .48 .52 .49 .47 .46
3 .59 .52 .47 .43 .57 .51 .46 .43 .49 .45 .42 .47 .44 .41 .46 .43 .40 .39
4 .54 .46 .41 .36 .52 .45 .40 .36 .44 .39 .36 .42 .38 .35 .41 .37 .35 .33
5 .49 .41 .35 .30 .47 .40 .34 .30 .38 .34 .30 .37 .33 .30 .36 .32 .29 .28
6 .45 .36 .30 .26 .44 .36 .30 .26 .34 .29 .26 .33 .29 .26 .32 .28 .25 .24
7 .41 .32 .27 .23 .40 .32 .26 .23 .31 .26 .22 .30 .25 .22 .29 .25 .22 .21
8 .38 .29 .23 .19 .37 .28 .23 .19 .28 .23 .19 .27 .22 .19 .26 .22 .19 .18
9 .35 .26 .20 .17 .34 .26 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .16 .15
10 .32 .24 .18 .15 .32 .23 .18 .15 .23 .18 .15 .22 .18 .15 .21 .17 .14 .13
3 LAMP
ROOM CAVITY RATIOS
Spacing Criteria: End = 1.3 Diagonal = 1.3 Cross = 1.4
% EFFECTIVE CEILING 20% EFFECTIVE FLOOR CAVITY REFLECTANCE
CAVITY REFLECTANCE rcc .80 .70 .50 .30 .10 .00
% WALL REFLECTANCE rw .70 .50 .30 .10 .70 .50 .30 .10 .50 .30 .10 .50 .30 .10 .50 .30 .10 .00
0 .78 .78 .78 .78 .76 .76 .76 .76 .73 .73 .73 .70 .70 .70 .67 .67 .67 .65
1 .71 .68 .66 .63 .70 .67 .64 .62 .64 .62 .60 .62 .60 .58 .59 .58 .57 .55
2 .65 .60 .56 .52 .63 .59 .55 .51 .56 .53 .50 .54 .51 .49 .52 .50 .48 .46
3 .60 .53 .48 .43 .58 .52 .47 .43 .50 .46 .42 .48 .45 .42 .46 .43 .41 .39
4 .54 .47 .41 .37 .53 .46 .41 .36 .44 .40 .36 .43 .39 .35 .41 .38 .35 .34
5 .50 .41 .35 .31 .48 .40 .35 .31 .39 .34 .30 .38 .33 .30 .36 .33 .30 .28
6 .45 .37 .31 .26 .44 .36 .30 .26 .35 .30 .26 .34 .29 .26 .33 .29 .26 .24
7 .42 .33 .27 .23 .41 .32 .27 .23 .31 .26 .23 .30 .26 .22 .29 .25 .22 .21
8 .38 .29 .24 .20 .37 .29 .33 .20 .28 .23 .20 .27 .23 .19 .26 .22 .19 .18
9 .35 .26 .21 .17 .34 .26 .21 .21 .17 .25 .20 .17 .24 .20 .17 .24 .20 .17
10 .33 .24 .19 .15 .32 .24 .18 .15 .23 .18 .15 .22 .18 .15 .22 .18 .15 .14
2 LAMP
ROOM CAVITY RATIOS
Spacing Criteria: End = 1.3 Diagonal = 1.3 Cross = 1.4
% EFFECTIVE CEILING 20% EFFECTIVE FLOOR CAVITY REFLECTANCE
CAVITY REFLECTANCE rcc .80 .70 .50 .30 .10 .00
% WALL REFLECTANCE rw .70 .50 .30 .10 .70 .50 .30 .10 .50 .30 .10 .50 .30 .10 .50 .30 .10 .00
0 .78 .78 .78 .78 .76 .76 .76 .76 .73 .73 .73 .70 .70 .70 .67 .67 .67 .65
1 .71 .68 .66 .63 .70 .67 .64 .62 .64 .62 .60 .62 .60 .58 .59 .58 .57 .55
2 .65 .60 .56 .52 .63 .59 .55 .51 .56 .53 .50 .54 .51 .49 .52 .50 .48 .46
3 .60 .53 .48 .43 .58 .52 .47 .43 .50 .46 .42 .48 .45 .42 .46 .43 .41 .39
4 .54 .47 .41 .37 .53 .46 .41 .36 .44 .40 .36 .43 .39 .35 .41 .38 .35 .34
5 .50 .41 .35 .31 .48 .40 .35 .31 .39 .34 .30 .38 .33 .30 .36 .33 .30 .28
6 .45 .37 .31 .26 .44 .36 .30 .26 .35 .30 .26 .34 .29 .26 .33 .29 .26 .24
7 .42 .33 .27 .23 .41 .32 .27 .23 .31 .26 .23 .30 .26 .22 .29 .25 .22 .21
8 .38 .29 .24 .20 .37 .29 .23 .20 .28 .23 .20 .27 .23 .19 ..26 .22 .19 .18
9 .35 .26 .21 .17 .34 .26 .21 .17 .25 .20 .17 .24 .20 .17 .24 .20 .17 .15
10 .33 .24 .19 .15 .32 .24 .18 .15 .23 .18 .15 .22 .18 .15 .22 .18 .15 .14
4 LAMP
ROOM CAVITY RATIOS
Spacing Criteria: End = 1.3 Diagonal = 1.3 Cross = 1.4
HFX-430-12
Lamp Type F40T12RS/WW
2 – 48" 40 Watt 3200 Lumen
Warm White Lamps
HFX-430-13
Lamp Type F40T12RS/WW
3 – 48" 40 Watt 3200 Lumen
Warm White Lamps
HFX-430-14
Lamp Type F40T12RS/WW
4 – 48" 40 Watt 3200 Lumen
Warm White Lamps
QL SERIES LIGHTING
QUARTZ FLOODLIGHTS
L186
L186
FEATURES-SPECIFICATIONS
QL-1505KQL-500K Certified
Applications
Provides maximum light output with low
initial cost. Designed for instant turn-on
and high illumination levels where H.I.D.
costs are prohibitive. Used to illuminate
construction sites, security areas, sports
areas, sign lighting and other applica-
tions.
QL Series Features
Tempered Glass Lens Assembly—
Thermal shock-and impact-resistant
glass lens mounted in a die cast
aluminum door frame
Cast Aluminum Housing—The cast
aluminum body is designed with a
specialized heat dissipating fin system
for cooler operation
Versatile Mounting—The standard unit
has a 1⁄2 inch swivel knuckle with cast
construction for strength and durability
High Temperature Gasketing—A weath-
ertight seal is provided by a high tem-
perature silicone door gasket
Exclusive Socket System—This two-
piece, high temperature socket allows
easy relamping and prevents socket
from binding
Reflector—Linear parabolic reflector
system provides maximum light output
and control
High Temperature Gasketing—A weath-
ertight seal is provided by a high tem-
perature silicone gasket attached to the
housing. Four lens clips positively seal
the lens to the gasket with consistent
pressure to assure a weathertight seal
CATALOG NUMBER LAMP AND WATTAGE BEAM SPREAD WEIGHT E.P.A. SQ. FT.
QL-500K1300/500 Wide 4 Lbs. (1.8) .53
QL-500K-WQ2300/500 Wide 4 Lbs. (1.8) .53
QL-1505K31000/1500 Wide 6 Lbs. (2.7) .86
QL-1505K-WQ2 3 1000/1500 Wide 6 Lbs. (2.7) .86
QL QUARTZ FLOODLIGHTS
Versatile Mounting—The standard unit
has a 1⁄2 inch swivel knuckle with cast
construction for strength and universal
aiming
See photometric data for QL Series
fixtures on page L187.
DESCRIPTION QL-500K QL-1505K
Guard QL-5G QL-15G
Trunnion Box QL-TB
Lens ONLY 0461330B 0461331B
Socket (2 Required) K800-2166-0108 0732016B
1/2" Knuckle K20750110214
Lens Gasket K265-0481-0307
ACCESSORIES/REPLACEMENT PARTS
Guard Trunnion Box
1Lamps not included.
2Lamps supplied-shipped separately. 500W 120V, 1500 240V.
31500W models must be aimed 10° or more below horizontal.
QL-1500 Watt QL-500 Watt QL-1500 and QL-500 Watt
Dimensions
QL/EM/DM SERIES LIGHTING
FLOODLIGHT PHOTOMETRICS L187
L187
L
EM/DM SERIES
QL SERIES
500 Watt Tungsten Halogen
Footcandle Array Based on:
15' Mounting Height
Aimed at 30° below horizontal
Not to scale. All values are initial footcandles.
Data calculated from Test No. HP-02305.
QL SERIES
QL-500K
Test No: HP-00930 IES/NEMA Type: 5H X 5V
Source: Incandescent Beam Spread Horiz: 88°
Lamp: Q500T3/CL Beam Spread Vert: 82°
Watts: 500 Beam Efficiency: 65%
LCL: Beam Lumens: 7060
Lumens: 10950 Max. Beam Candle: 9265
Avg. Max. Candle: 8356
QL-1505K
Test No: HP-00854 IES/NEMA Type: 6H X 5V
Source: Incandescent Beam Spread Horiz: 115°
Lamp: Q1500T3/CL Beam Spread Vert: 78°
Watts: 1500 Beam Efficiency: 68%
LCL: Beam Lumens: 24306
Lumens: 35800 Max. Beam Candle: 33219
Avg. Max. Candle: 28374
See page L188 for catalog data.
Listed - File E89665 and E97760
Certified - File LR11713
Class I, Div. 1 & 2 Groups C,D
Class I, Zones 1 & 2 Groups llB,llA
Class II, Div. 1 & 2, Groups F,G
Class III, Div. 1 & 2
NEMA 3, 4X, 7(C,D) 9(F,G)
Suitable for wet locations
EMHPO71
EM/DM SERIES LIGHTING
HID PORTABLE FLOODLIGHTS
L188
L188
FEATURES-SPECIFICATIONS
Applications
EM & DM Series portable floodlights
provide emergency or maintenance light-
ing in wet locations or areas made haz-
ardous due to the presence of flammable
gases or vapors and combustible dusts
as defined by the NEC.
Typical uses are in manufacturing plants,
chemical, petrochemical and other indus-
trial process facilities, oil refineries, grain
storage sights, aircraft maintenance and
refueling areas, tank farms and pipeline
pumping stations.
Features
Factory sealed 100 foot 16/3 SOW cord
supplied as standard. See catalog
section PR for Acceptor®plugs and
receptacles
Corrosion resistant, rain tight, copper-
free cast aluminum housing helps
assure safe, reliable operation
Light weight, strong spun aluminum
base provides stability, permits hanging
fixture temporarily on wall or lowering it
inverted
Aluminum specular reflector directs light
beam for concentrated illumination
Tempered glass lens resists heat and
shock
Nitrile rubber O-ring gasketing provides
an excellent seal for use in wet locations
EM/DM HPS PORTABLE FLOODLIGHTS
RATED CLA SS I, DIV. 1 & 2 C LASS II, DIV. 1 & 2 CLASS III, DIV. 1 & 2
SERIES LAMP LAMP AMBIENT MAX. SURFACE T EMP. MAX. SURFACE TE MP. MAX. SURFACE TEMP.
TYPE WATTS DEGREES UL/CSA UL/CSA UL/CSA UL/CSA UL/CSA
°F/°C TEMP. I.D. °F/°C GROUPS TEMP. I.D. °F/°C GROUPS TEMP. I.D. °F/°C
EMS HPS 150 77°/25° T3C (320°/160°) CD —— —
DMS HPS 100 104°/40° T4A (248°/120°) CD T3C (320°-160°) FG T3C (320°-160°)
EMH MH 70 104°/40° T4 (275°/135°) CD T3 (392°-200°) F—
EMI INC 110 104°/40° T3A (356°/180°) CD T3 (392°-200°) F—
EMI INC 150 104°/40° T3A (356°/180°) CD —— —
EM INCANDESCENT1
1Refer to hazardous location application data below for specific T codes and temperatures.
2EMIP111 can be used with PAR 38 150 Watt incandescent lamp. See hazardous location application
data.
* DMS series units have a limiting device to prevent positioning of the fixture head in an orientation where
dust could build up on the lens. Any attempt to defeat its purpose can be dangerous.
CATALOG LAMP VOLTAGE
NUMBER WATTS @60 HERTZ DESCRIPTION1
EMSP151 150 120 Class I, Div. 1 & 2, Groups C & D
DMSP101* 100 120 Class I, Div. 1 & 2, Groups C & D; Class II, Div. 1 & 2,
Groups F & G; Class III
E M M H
EM INCANDESCENT
EMIP111 110 120 Class I, Div. 1 & 2, Groups C & D; Class II, Div. 1 & 2, Group F
EMHP071 70 120 Class I, Div. 1 & 2, Groups C & D; Class II, Div. 1 & 2, Group F
1Do not install where marked operating temperature exceeds ignition temperature of Hazardous Atmosphere.
Photometric data—see page L187
Lamps included on all models
Compliances
UL-844 portable electric lighting units
for use in hazardous locations
UL-1598 standard for incandescent or
HID lighting fixtures
UL Marine type electric lighting fixtures
CSA-C22.2 nos. 12 & 137
NEMA 3, 4
Dimensions
KF SERIES LIGHTING
FLOODLIGHTS, 150-1000W HID L189
L189
FEATURES-SPECIFICATIONS
L
Suitable for wet locations
NEMA 4X, IP66
Type Approval
Type approval for shipboard use1
Class I, Div. 2 Groups A,B,C,D8
Class I, Zone 2, Groups llC,llB,llA (nR7)
ABS
NEW!
Applications
KF series floodlights can be used in
industrial installations where flammable
gases or vapors may exist due to
abnormal conditions resulting in the
creation of a Class I, Div. 2 hazardous
location as defined by the NEC. Also
can be used where general corrosive
atmospheric conditions exist such as
ocean piers, marinas and costal areas.
Designed for heavy duty applications
where long life and maintenance-free
service are essential.
Features
Rugged weathertight housing of
copper-free aluminum with corrosion
resistant bronze finish
Wide beam distribution
Thermal shock, impact-resistant lens
Continuous silicone gasketing
All external hardware is corrosion
resistant including HubbellGard®
ceramic coated screws
Trunnion mounting-heavy gauge, hot
dip galvanized steel mounting with
stainless steel hardware
Photometric data & accessories—see
page L191
3/4" NPT entry on back lower left
Front
Side
Trunnion Mounting Detail
25"
(647)
1Not suitable for submersion or wave impact.
2MH175,250,400 are EXPORT ONLY (EISA
LAW).
3Consult factory for other available voltage/
lamp combinations.
41000 Watt fixture aiming angle limited to 45°-
135° (no straight up or down) 1000 Watt fix-
tures are rated and listed for 40° ambient.
5Use Phillips C1000S52/ED37 11-1/2" lamp for
1000 HPS.
Elevated Ambients to 55°C —
Consult T-Code Chart
for suitability.
CATALOG LOGIC
KF P 40 0 -76 NR F1 P1 AS
12 345 6
1KF - Series Constant (aluminum flood)
2Lamp Type
S = High Pressure Sodium
H = Metal Halide
P = Pulse Start Metal Halide
3Wattage
07 = 70 Watt (HPS)
10 = 100 Watt (HPS)
15 = 150 Watt (MHP, HPS)
17 = 175 Watt (MH, MHP)2
20 = 200 Watt (MHP)
25 = 250 Watt (MH, MHP, HPS)2
32 = 320 Watt (MHP)
35 = 350 Watt (MHP)
40 = 400 Watt (MH, MHP, HPS)2
100 = 1000 Watt (MH, HPS)456
4Voltage*3
0 = Quad - 120, 208, 240, 277V - 60Hz
5 = 480V
6 = Tri - 120, 277, 347V (for Canada only)
7 = 220V 60Hz
8 = 220/240V 50 Hz
5- 76 Series Constant (7 x 6 optic pattern)
6Options
• NR - Ex nR Restricted Breathing (Ex nR II)
• IR - Instant Restrike 150W HPS**
• BP - 150 - 400 HPS**
• Fuse option 400W max. (not for Marine or CSA)
F1 single 120V F5 double 480V
F2 double 208V F6 single 347V
F3 double 240V F7 double 220V
F4 single 277V F8 single 230V 50Hz
• Photocell option (400W max.)
P1 120V P1 208-277V P1 347V
• Terminal Blocks
TBx x=1-8 x = voltage code
TBLx Lx=1-8 looping x = voltage code
• Lamps
AS = Assembled Standard Lamp
AD = Assembled Dual-Arc-Tube Lamp;
150, 250, 400HPS only
6Use 11-1/2" BT37 lamp available from GE,
Venture or Phillips (MH).
7NR suffix Restricted Breathing models provide
lower T-codes - Requires sealed entry.
8Consult T-code chart for suitability.
T-Codes=>306 are suitable for
Groups B,C,D only.
**IR & BP cannot be ordered together.
KF SERIES • LIGHTING
ORDERING INFORMATION • ACCESSORIES
L190
L190
KFS-6 KFWB K4040 4041
KFCB
ORDERING INFORMATION
CATALOG NUMBER DESCRIPTION
KFS-6 Steel slipfitter for 2" pipe (2-3/8" o.d.) tenon. Slips 3.75" over pipe.
KFCB Heavy duty cast-iron crossarm fitting for horizontal trunnion
KFWB Heavy duty wall mount and/or pipe clamp fitting
Clamps 2" pipe (2-3/8" o.d.) thru 2-1/2" pipe (2-7/8" o.d.)
K4040 Heavy duty steel wall bracket. (Must use with KFCB crossarm fitting)
4041 Heavy duty steel wall bracket 2" pipe (2-3/8" o.d.) tenon fitting
KF-Door Replacement Door & Lens assembly
KF MOUNTING ACCESSORIES1
1Fittings available to adapt trunnion mount floodlights to crossarms, poles and walls.
Must be ordered separately.
* Consult T-Code Chart for hazardous location suitability.
4Consult factory for other available voltages.
51000 watt fixture aiming angle limited to 45°-135° (no straight up or
down) 1000 watt fixtures are rated and listed for 40° ambient.
6Use Philips C1000S52/ED37 11-1/2" lamp.
CATALOG LAMP AND VOLTS BEAM SPREAD
NUMBER WATTAGE 4H° X V°
KFP150-76 150 MHP QUAD 7 (145°) X 6 (114°)
KFP155-76 M-102/142 480
KFP170-76 175 MH QUAD 7 (1450) x 6 (1140)
KFP175-76 M-137/152 480
KFP200-76 200 MH QUAD 7 (1450) x 6 (1140)
KFP205-76 M-136 480
KFP250-76 250 MHP QUAD 7 (1450) x 6 (1140)
KFP255-76 M-138 480
KFP320-76 320 MHP QUAD 7 (1460) x 6 (1190)
KFP325-76 M-132 480
KFP350-76 350 MHP QUAD 7 (1460) x 6 (1190)
KFP355-76 M-131 480
KFP400-76 400 MHP QUAD 7 (1460) x 6 (1190)
KFP405-76 M-135 480
MH, PULSE START ORDERING INFORMATION*
CATALOG LAMP AND VOLTS BEAM SPREAD
NUMBER WATTAGE 4H° X V°
KFS070-76 70 HPS QUAD 7 (144°) X 6 (113°)
KFS075-76 M-102/142 480
KFS100-76 100 HPS QUAD 7 (145°) x 6 (114°)
KFS105-76 M-137/152 480
KFS150-76 150 HPS QUAD 7 (144°) x 6 (113°)
KFS155-76 S-55 480
KFS250-76 250 HPS QUAD 7 (144°) x 6 (113°)
KFS255-76 S-50 480
KFS400-76 400 HPS QUAD 7 (144°) x 6 (113°)
KFS405-76 S-51 480
KFS1000-76 1000 HPS QUAD 7 (130°) x 6 (114°)
KFS1005-76 S-52 45 480
KFH170-76 170 MH QUAD 7 (145°) x 6 (114°)
KFH175-76 M-57 480
KFH250-76 250 MH QUAD 7 (145°) x 6 (114°)
KFH255-76 M-58 480
KFH400-76 400 MH QUAD 7 (146°) x 6 (119°)
KFH405-76 M-59 480
KFH1000-76 1000 MH QUAD 7 (145°) x 6 (114°)
KFH1005-76 M-47 46 480
HPS, MH, START ORDERING INFORMATION*
E
X
P
O
R
T
O
N
L
Y
KF SERIES • LIGHTING
APPLICATION DATA • PHOTOMETRICS L191
L191
L
LUMINAIRE C1D2 C1Z2NR SUPPLY AIMING RANGE &
WATTAGE AMBIEN T T-CODE1T-CODE2WIRE C° DIAGRAM3
HAZARDOUS LOCATION APPLICATION DATA
70W HPS 40C T2B T4 75 180° - 0° A
55C T2B T4 75 180° - 0° A
65C T2B T4 90 180° - 0° A
100W HPS 40C T2B T4 75 180° - 0° A
55C T2B T4 75 180° - 0° A
65C T2B T4 90 180° - 0° A
150W HPS 40C T2B T4 75 180° - 0° A
55C T2B T4 90 180° - 0° A
65C T2B T4 105 180° - 0° A
250W HPS 40C 325C T4 90 180° - 0° A
55C 325C T3 105 180° - 0° A
65C 325C T3 105 135° - 0° B
400W HPS 40C 357C T3 90 180° - 0° A
55C 363C T3 110 135° - 0° B
65C XXX XXX NA XXX NA
1000W HPS 40C T1 T2 110 135°-45° C
55C XXX XXX NA XXX NA
65C XXX XXX NA XXX NA
175MH 40C 350C T4 90 180° - 0° A
55C 350C T3 105 180° - 0° A
65C 325C T4 105 135° - 45° C
250W MH 40C 350C T4 90 180° - 0° A
55C 350C T3 105 180° - 0° A
65C 325C T4 105 135° - 45° C
400W MH 40C 325C T3 105 135° - 0° B
50C 301C T3 105 90° - 45° D
65C XXX XXX NA XXX NA
1000W MH 40C 442C T2 110 135°-45° C
55C XXX XXX NA XXX NA
65C XXX XXX NA XXX NA
150W MHP 40C 325C T4 90 180° - 0° A
55C 325C T3 90 180° - 0° A
65C 325C T3 105 180° - 0° A
175W MHP 40C 325C T4 90 180° - 0° A
55C 325C T3 90 180° - 0° A
65C 325C T3 105 180° - 0° A
200W MHP 40C 325C T4 90 180° - 0° A
55C 325C T3 90 180° - 0° A
65C 325C T3 105 180° - 0° A
250W MHP 40C 350C T3 90 180° - 0° A
55C 350C T3 105 180° - 0° A
65C XXX XXX NA XXX NA
320W MHP 40C 366C T3 90 180° - 0° A
55C 366C T3 105 180° - 0° A
65C XXX XXX NA XXX NA
350W MHP 40C 350C T3 90 180° - 0° A
55C 350C T3 110 135° - 45° C
65C XXX XXX NA XXX XXX
400W MHP 40C 350C T3 90 180° - 0° A
55C 325C T3 110 135° - 45° C
65C XXX XXX NA XXX XXX
Aiming Figures Based on Ambient & Lamp3
PHOTOMETRIC DATA
KF SERIES
1In converting to a different mounting height,
multiply all footcandle values by the correc-
tion factor and convert the grid size to the
mounting height selected. Example: to
convert 25 foot to 30 foot mounting height,
multiply all footcandle values by .69. (Grid
now becomes 30 replacing 25). To convert
footcandles to Lux, multiply values by 10.76.
To convert feet to meters, divide values
by 3.281.
1Temperatures equal or higher than 306˚C are suitable for Groups
B,C,D only.
2C1D2 NR Restricted Breathing requires Sealed Entry.
3Aiming angle limited by ambient temperature and lamp type - See
Diagrams.
KFH-XXX-76
IES Type—7H x 6V (146° x 119°)
Source—Metal Halide (Clear) 34000 Lumens
Wattage—400 (ANSI M59)
For 250W MH multiply by .6
For 1000W MH multiply by 3.1
Mounting Height (Grid Value)—25 feet
Aliming Angle—45°
Test Number–HP-00738
KFS-XXX-76
IES Type—7H x 6V (144° x 117°)
Source—High Pressure Sodium (Clear) 50000 Lumens
Wattage—400 (ANSI S51)
For 150W HPS multiply by .32
For 250W HPS multiply by .6
For 1000W HPS multiply by 2.5
Mounting Height (Grid Value)—25 feet
Aliming Angle—45°
Test Number–HP-00740
CONVERSION CHART
MOUNTING HEIGHT (FEET) 23 25 30 35 40
CORRECTION FACTOR 1.18 1.00 .69 .51 .39
CONVERSION CHART
MOUNTING HEIGHT (FEET) 20 25 28 30 35
CORRECTION FACTOR 1.56 1.00 .80 .69 .51
BCDA
KFSS SERIES LIGHTING
MARINE FLOODLIGHTS, 150-400W HID
L192
L192
FEATURES-SPECIFICATIONS
Class I Div. 2, Groups A,B,C,D*
AEx nR/Ex nR**
Class I Zone 2, IIC, IIB, IIA*
UL 1598 HID Marine for Wet Locations
UL 844 Hazardous Locations
CSA C22.2 9.9-9.6 General Requirements
CSA C22.2 137-M1981 Hazardous
Locations
CSA Enclosure type IP66/67
ABS Type Approval for Shipboard Use
* Consult temperature data table on next page to
determine application suitability.
KFS-6G
Steel Slipfitter
(includes bolts)
K4040G
Steel Wall/Pole Bracket
KFCBG
Cross Arm Fitting
KF 0 00 0 SS (NR)**
Catalog Number Logic
Series Constant Series Constant
Lamp Type
S—High Pressure Sodium
H—Metal Halide
P—Pulse Start Metal Halide
Lamp Wattage
15—150 Watt, HPS
25—250 Watt, HPS, MH, MHP
40—400 Watt, HPS, MH, MHP
Voltage
0—Quad; 120/208/240/277 60 Hz.
5—480 60 Hz.
6—Tritap 120/277/347 60 Hz. (Canada)
7—220 60 Hz. (S. America),
MHP250 & MHP 400 N/A
8—220/240 50 Hz.
(Europe & S. America),
MHP250 N/A
Applications
Offshore production platforms
Refineries
Offshore drilling rigs and barges
Ocean-going vessels
Commercial fishing vessels
Ports, wharfs and jetties
Waste water and sewage treatment
facilities
Any type of washdown, corrosive,
abrasive, or dirty environment
Features and Benefits
Type 316 Stainless Steel Housing.
16-gauge housing ensures low
corrosion and long life, reducing
maintenance costs
Rugged quick-release 316 SS Lens
Latches. No hardware seizing on
disassembly saves maintenance
time and money. Only tool needed
is a screwdriver
316 SS Safety Lens Door Chains.
Enables hands-free safe re-lamping
316 SS Mounting Yoke Reliable and
safe installation
Highly efficient photometrics and
excellent asymmetrical distribution.
Photometrics above 85%. Minimizes
the number of required fixtures to
deliver desired light levels. Saves in
energy costs
Hot-dipped Galvanized Steel
Mounting Accessories. Corrosion
resistant in marine and corrosive
environments, assuring reliable
installation
316 SS 3/4" Conduit Hub. Maintains
grounding continuity. Watertight
seal. Corrosion resistant
Silicone Gasketed Lens Door Frame.
Provides watertight seal, protecting
interior from moisture and corrosives
KFSS STAINLESS STEEL FLOOD LIGHTS
KFSS ACCESSORIES
KFS150SS
KFS156SS
KFS250SS
KFS256SS
KFS400SS
KFS406SS
KFH250SS
KFH256SS
KFP250SS
KFP256SS
KFH400SS
KFH406SS
KFP400SS
KFP406SS
150 HPS
S-55
250 HPS
S-50
400 HPS
S-51
250 MH2
M-58
250 MHP3
M-138
400 MH2
M-59
400 MHP3
M-135
CATALOG
NUMBER
CATALOG NUMBER DESCRIPTION
LAMP TYPE
AND CIRCUIT VOLTAGE1VBEAM SPREAD
H° X V°
6 (118) x 6 (118)
6 (118) x 6 (118)
6 (118) x 6 (118)
6 (118) x 6 (118)
6 (118) x 6 (118)
6 (118) x 6 (118)
6 (118) x 6 (118)
120/208/240/277 @60Hz
120/277/347 @60 Hz
120/208/240/277 @60Hz
120/277/347 @60 Hz
120/208/240/277 @60Hz
120/277/347 @60 Hz
120/208/240/277 @60Hz
120/277/347 @60 Hz
120/208/240/277 @60Hz
120/277/347 @60 Hz
120/208/240/277 @60Hz
120/277/347 @60 Hz
120/208/240/277 @60Hz
120/277/347 @60 Hz
KFS-6G
K4040G
KFCBG
Steel slipfitter for 2" pipe (2-3/8" O.D.) tenon. Hot-dipped galvanized (bolts included)
Steel wall/pole bracket. Hot-dipped galvanized (bolts included)
Cross arm fitting for horizontal trunnion. Hot-dipped galvanized (bolts included)
1Voltage: 6th character in the catalog number denotes voltage. See “Catalog Number Logic” for details; e.g.
KFS155SS = 480 Volt 60Hz.; KFH408SS=240V 50HZ.
2Mercury Vapor Lamps of the same wattage may be used if desired.
3Use a Pulse Start Metal Halide Lamp rated for Horizontal Position.
VConsult factory for available lamp and voltage combinations.
**Restricted Breathing option-see next page.
KFSS SERIES LIGHTING
MARINE FLOODLIGHTS L193
L193
L
MARIGARD TEMPERATURE CODES
ANGLE FROM BEAM AXIS (DEGREES HORIZONTAL)
HPS
HPS
HPS
HPS
HPS
HPS
MH-MHP-MV
MH-MHP-MV
MH-MHP-MV
Test Number: HP-07477
Source: HPS
Lamp: ED-18
Lamp Watts: 400
LCL: 5.75"
Lumens: 50,000
IES/NEMA Type: 6H x 6V
Maximum Beam Candlepower: 36,447
Average Maximum Candlepower: 32,045
Total Efficiency: 85.41%
RATED
AMBIENT C°
TYPE
LAMP
HORIZONTALLY VERTICALLY LUMENS
BEAM
FIELD
EFFICIENCY
WATTAGE
CLASS 1 DIV. 2
TEMP. (CODE)
270°C (T2A)
285°C (T2)
295°C (T2)
380°C (T1)
395°C (T1)
380°C (T1)
365°C (T1)
380°C (T1)
365°C (T1)
CLASS 1 ZONE 2
TEMP. (CODE)
270°C (T2)
285°C (T2)
295°C (T2)
380°C (T1)
395°C (T1)
380°C (T1)
365°C (T1)
380°C (T1)
365°C (T1)
T4
T4
T3
T3
T3
T3
T3
T2
T3
150
150
150
250
250
400
250
250
400
40
55
65
40
55
40
40
55
40
81.8
118.4
41.0
118.6
44.39%
81.18%
22,196
40,591
90°C
90°C
110°C
90°C
110°C
110°C
110°C
110°C
110°C
Dimensions
17.95"
(456mm)
SUPPLY
WIRE C°
Ex nR
1
1Ex nR with NR adder. Allows lower T-CODE approvals through the use of sealed
cable entrance fittings. See fittings section or select other gland/connector as
appropriate for type of cable used.
ANGLE FROM BEAM AXIS (DEGREES VERTICAL)
AVERAGE OF RIGHT-LEFT SIDES
ISO CANDELA CURVES LUMEN DISTRIBUTION
ANGLE FROM BEAM AXIS (DEGREE HORIZONTAL)
VERTICAL TOTALS
HORIZONTAL TOTALS
AXIAL CANDELA TRACES
LUMINOUS INTENSITY - CANDELA
LEFT/DOWN DEGREES UP/RIGHT
VERTICAL - HEAVY LINE HORIZONTAL - THIN LINE
MARINE FLOODLIGHTS
Rugged yet easy-to-open 316
SS Latches require no special
tools!
Two 316 SS Lens Chains
allow for hands-free mainte-
nance!
KWP SERIES LIGHTING
WALLPACK, 70-175W HID
L194
L194
FEATURES-SPECIFICATIONS
Class I, Div. 2, Groups A,B,C,D
Class I, Zone 2, Groups IIC, IIB, IIA
NEMA 4X
Certified
Applications
KWP Wall Luminaires are ideally suited
for applications requiring a pleasing
aesthetic appearance or hazardous
location suitability in a compact energy
saving fixture. Units are of copper-free
aluminum construction for cool opera-
tion with a bronze electrostatically
applied powder-coat finish. Suitable for
locations such as perimeter security
lighting, parking areas, factories and
parking garages.
Features
Aluminum with Bronze finish 1/2" hub
on either side for conduit entry
Mogul Porcelain Socket
Reflector is specular aluminum preci-
sion formed for optimal performance
Suitability for 40°C ambient, 90°C
supply wire required
Lens thermal shock and impact
resistant prismatic borosilicate glass
Full front access available for lamp or
ballast service by hinging front door
Two Hubbell Guard®Corrosion
resistant hex head fasteners provide
water-tight seal for door gasket
Options include:
factory installed photo cells, fusing,
instant restrike, ballast protector
and lamps
Compliances
UL 1598 Standard for Luminaires
UL 844 Standard for lighting fixtures
for hazardous locations
CSA C22 no. 137-M1981
electric luminaires for use in
hazardous locations
Enclosed and gasketed
NEMA 3, 4X
Wall Pack Luminaires
Catalog Logic
KWP P 15 0 P1
12345
1KWP - Series Constant (Wallpack)
2Lamp Type
S = High Pressure Sodium
H = Metal Halide
P = Metal Halide Pulse
3Wattage
05 = 50 Watt HPS
07 = 70 Watt (HPS, MH)
10 = 100 Watt (HPS, MH)
15 = 150 Watt (HPS, MHP)
17 = 175 Watt (MH, MHP)
4Voltage
0 = 120, 208, 240, 277V @ 60Hz (QUAD)
5 = 480 @60Hz
6 = 120, 277, 347 @ 60Hz (for Canada)
7 = 220 @ 60Hz
8 = 220/240V @ 50Hz
5Options
FUSING - (Not for Canada or Marine applications)
F1 single 120V 60Hz F5 double 480V 60Hz
F2 double 208V 60Hz F6 single 347V 60Hz
F3 double 240V 60Hz F7 double 220V 60Hz
F4 single 277V 60Hz F8 single 230V 50Hz
Photocells (Factory installed)
P1 120V
P2 208-277V (field connection to correct ballast tap)
P3 347V
Other Options
IR Instant Restrike HPS to 150w - not available with BP
BP Ballast Protector HPS - Not available with IR
Terminal Blocks Assembly with Lamps
TBx x=1-8 AS Standard lamp
TBLx x=1-8 looping AD Dual-Arc-Tube (70-150 HPS)
KWP SERIES LIGHTING
WALLPACK, 70-175W HID L195
L195
ORDERING INFORMATION
L
Photo Cell Field Kits for Harsh
NEMA 4X and Class I, Div. 2 Locations*
Clear Shield Wire Guard
Glare Shield
CATALOG LAMP VOLTAGE1T-COD E AT
NUMBER TYPE 400 C
KWPS050 50 HPS QUAD 215OC (T2D)
KWPS055 S-68 480
KWPS070 70 HPS QUAD 215OC (T2D)
KWPS075 S-62 480
KWPS100 100 HPS QUAD 215OC (T2D)
KWPS105 S-54 480
KWPS150 150 HPS QUAD 260OC (T2B)
KWPS155 S-55 480
KWPH070 70 MH QUAD 200OC (T3)
KWPH075 M-98 480
KWPH100 100 MH QUAD 200OC (T3)
KWPH105 M-90 480
KWPH170 175 MH QUAD 260OC (T2B)
KWPH175 M-57 480
KWPP150 150 MHP QUAD 260OC (T2B)
KWPP155 M102/142 480
KWPP170 175 MHP QUAD 260OC (T2B)
KWPP175 M137/152 480
HPS, MH, MHP ORDERING INFORMATION*
1
For other voltages, see logic.
E
I
S
A
O
N
L
Y
1/2” feed through surface hub conduit
E
X
P
O
R
T
FACTORY
SEALED
Order single gang FS back box seperately.
Can be used to control several luminaires.
* 40˚C ambient max. T3 to 400W max.
1Includes factory drilled FSBC cover
and gasket.
PHOTO CELL FIELD KITS1
VMFSPC1
VMFSPC2
VMFSPC3
CATALOG NUMBER
120VAC
208-277VAC
347VAC
VOLTS
KWP ACCESSORIES
CATALOG NUMBER DESCRIPTION
PGPS
PGWG
PVLV
KWPLENS
Clear Shield (Polycarbonate) for Protecting Lens
Wire Guard, Cadnium Plated Steel
Glare Shield Full Cutoff Visor - Formed Bronze Aluminum
Forces light to Walkway
Replacement Door and Lens
EZ SERIES LIGHTING
HID FLOODLIGHT FIXTURES
L196
L196
FEATURES-SPECIFICATIONS
Listed - file E10514
CSA LR11713
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB,llA
NEMA 3, 4, 4X, 7(C,D)
Factory Sealed
Shown with optional
VMPSD40 reflector
Applications
HOSTILELITE®EZ series trunnion
mount luminaires provide directional
lighting in both vertical and horizontal
planes when used with floodlight
mounting hardware.
Typical applications include refineries,
drilling rigs and platforms, loading
docks, bulk fuel loading terminals,
and pipeline pumping stations.
Features
Three light sources
– High Pressure Sodium (50-400W)
– Metal Halide (70-400)
– Metal Halide Pulse (175-400)
Trunnion mounted–Trunnion yoke of
316 grade stainless steel attaches via
mounting blocks to fixture ballast
housing
Factory sealed–No external seal
needed
Corrosion resistant–Fixture of copper-
free aluminum die cast construction.
Baked powder epoxy finish, electro-
statically applied. Exposed hardware
of 316 grade stainless steel
Accessories–Guards, reflectors and
mounting hardware available. Must be
ordered separately, see illustration
Mounting method–See page L197 for
typical installation using mounting
accessories
Compliances
UL-844 Electric Lighting Fixtures for
use in Hazardous Locations
UL-1598 Standard for HID Lighting
Fixtures
CSA C22.2 no. 137-M1981 Electric
Luminaires for use in Hazardous
Locations
NEMA 3, 4, 4X, 7CD
CLA S S I, DIV. 1 & 21
FIXTURE LAMP LAMP SUITABLE SUPPLY MAX. SURFACE TEMP. TYPE 3 TYPE 4 TYPE 4X
SERIES TYPE WATTS AMBIENT °C WIRE TEMP. I.D. (RAINTIGHT) (HOSEDOWN) (CORROSION
MIN. °C (ACTUAL TEMP.) GROUPS RESISTANT)
EZS HPS 50 40 85 T4 (135°C) C,D YES YES YES
EZS HPS 70 40 85 T4 (135°C) C,D YES YES YES
EZS HPS 100 40 85 T4 (135°C) C,D YES YES YES
EZS HPS 150 40 85 T4 (135°C) C,D YES YES YES
EZS HPS 250 40 85 T3C (160°C) C,D YES YES YES
EZS HPS 400 40 85 T3 (200°C) C,D YES YES YES
EZH MH 70 40 85 T4A (120°C) C,D YES YES YES
EZH MH 100 40 85 T4A (120°C) C,D YES YES YES
EZH MH 175240 85 T3B (165°C) C,D YES YES YES
EZH MH 250240 85 T3A (180°C) C,D YES YES YES
EZH MH 400240 85 T2D (215°C) C,D YES YES YES
EZP MHP 175/200 40 85 T3C (160°C) C,D YES YES YES
EZP MHP 250/320 40 85 T3 (200°C) C,D YES YES YES
EZP MHP 350/400 40 85 T2D (215°C) C,D YES YES YES
EZ HAZARDOUS LOCATION APPLICATION DATA
1T-Code with or without reflector.
2EXPORT ONLY (EISA LAW).
EZ SERIES LIGHTING
HID FLOODLIGHT FIXTURES L197
L197
FEATURES-SPECIFICATIONS
L
Listed - E10514
LR 11713
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups llB,llA
NEMA 3, 4, 4X, 7(C,D)
Factory Sealed
Shown with optional
VMPSD40 reflector3
WATTS ANSI LAMP VOLTAGE HUB CATALOG
TYPE @60 HERTZ SIZE NUMBER
50 HPS S-68 120, 208, 240, 277 EZS050A2-T
70 HPS S-62 120, 208, 240, 277 EZS070A2T
100 HPS S-54 120, 208, 240, 277 3/4"1EZS100A2-T
150 HPS S-55 120, 208, 240, 277 EZS150A2-T
250 HPS S-50 120, 208, 240, 277 EZS250A2-T
400 HPS S-51 120, 208, 240, 277 EZS400A2-T
EZ 50–400W HPS FLOODLIGHTS123
CATALOG
NUMBER DESCRIPTION
HPS 50-150
EZG1 MH 175-250
MV 100-250 Guard
VMAG40S5HPS 250-400
MH, MV 400
VMPSD40 Standard dome
HRD400 Deep dome white Reflector
HRD400ALZ Deep dome*
EZ ACCESSORIES3
1Luminaire catalog numbers provide for a single
3⁄4" NPT flexible conduit connection only.
For 1" NPT conduit connection, substitute
3” for “2” in catalog number; example:
EZS050A3-T.
2Consult page L156 for other available voltage.
3Accessories may be ordered with fixture as a
single catalog number with the following logic.
Components shipped separately.
4Optional Accessory.
5See options page L161.
6EXPORT ONLY (EISA LAW).
A. Flexible coupling. See page L221
for EKJ series
B. Splice box. See page L222 for
JL/JAL series
C. Trunnion yoke supplied with EZ-T
series floodlight fixture
D. Mounting accessory wall mount
(KFWB) shown. See page L190 for
this and other fittings available to
adapt trunnion mount floodlights to
crossarms, poles or walls
A
B
C
D
Installation Method
Typical EZ Series trunnion mounted
luminaire using conduit hardware.
EZH400A2G-TS
S-Standard Dome
Cat. No. VMPSD-40
D-Deep Dome
Cat. No. HRD-400
Z-Deep Dome
Cat. No. HRD-400ALZ
Trunnion
Guard
Base Catalog
Number (INC/“T”)
4
4
70 MH M-98 120, 208, 240, 277 EZH070A2-T
100 MH M-90 120, 208, 240, 277 EZH100A2-T
175 MH6M-57 120, 208, 240, 277 3/4"1EZH170A2-T
250 MH6M-58 120, 208, 240, 277 EZH250A2-T
400 MH6M-59 120, 208, 240, 277 EZH400A2-T
EZ 70–400W MH FLOODLIGHTS123
175 MHP M-137/M-152 120, 208, 240, 277 EZP170A2-T
200 MHP M-136 120, 208, 240, 277 EZP200A2-T
250 MHP M-138/M153 120, 208, 240, 277 3/4"1EZP250A2-T
320 MHP M-132/M154 120, 208, 240, 277 EZP320A2-T
350 MHP M-131 120, 208, 240, 277 EZP350A2-T
400 MHP M-135/M155 120, 208, 240, 277 EZP400A2-T
EZ 175–400W MH PULSE FLOODLIGHTS123
* Specular anodized finish.
D E 3 B | V E 3 B | V E 3 Q
DE4B | VE4B | VE4Q SERIES LIGHTING
COMPACT FLUORESCENT EMERGENCY FIXTURES
L198
L198
FEATURES-SPECIFICATIONS
Applications
CERTILITE®VEB and VEQ Emergency Lighting fixtures provide con-
tinuous illumination under normal power and switch to emergency
battery backup during power outages. Emergency Units ONLY are
available that operate only when normal power fails.
Units contain battery unit(s) that provides the OSHA required 90 min-
utes of illumination for egress.
DExx units are designed for general and task lighting in indoor or out-
door wet locations or where combustible dusts may exist and create a
hazardous location, as defined by the NEC.
VExx units are designed for general and task lighting in indoors or
outdoors where flammable gases or vapors, combustible dusts, or
simultaneous presence may exist and create a hazardous location, as
defined by the NEC.
Use Push-To-Test station suitable for area of use for testing purposes.
Features
Bi-Pin Twin D(V)ExB or Quad-Pin triple-tube (VExQ) long-life com-
pact fluorescent lamps included
World Voltage on Quad-Pin VExQ Series: 120 through 277VAC; 50
through 60 Hz
LED charging indicator light visible through lens
Pre-wired terminal block for easy power connection
Two lamp models include two independent redundant systems
Six mounting splice box types - Pendant, Ceiling, Wall bracket,
Cone Top, 25° Angle Stanchion, Straight Stanchion.
Normally shipped as components for fast delivery, or may be
ordered factory assembled.
Options for Fuses and Quick Disconnect
FEATURES BENEFITS
Swing-Barrel Nut
Patented Tank
Mounting System
• Stainless-to-Stainless securement
• Takes load off during installation
• Uses ordinary tools
• Saves time and labor
Sealed Optic Zone 2
AEx nAR Restricted
Breathing (suffix NR)
NO External Seals. Lower T-codes, Suitable
for Class I Div. 2 Classified areas per the
NEC®. See L54 for more information.
All glass refractors Compact (5-1/2" thread size, types I & V)
Standard (7-3/4", thread size,types I, III, V)
Enhances user selection flexibility
“EZ” mount adapter Easier Maintenance, saves labor, move
fixture from the ladder to the workbench
Photo controls -Class
I Div. 2 / N4X areas
(VExx) tanks only
Available as Field or Factory Installed
to save energy when light not required.
For AC ballast only.
Earthquake Tab -
Built-in attachment
point for safety cables
Safety: Secures fixture to structure in case
of conduit failure. “3rd hand” acces-
sories for lamp change out. See L53
for more information.
VMEP40
“Food Optic”
VQ2F
Expanded Offering
for Food or Grain Handling Applications to
minimize contamination. See L53 for more
information.
I III V
DE3B/DE4B
Class II, Div. 1 & 2, Groups E,F,G1
Class III
NEMA 3, 4, 4X; IP66
VE4B/VF4B/VE3Q/VE4Q
Class I, Div. 2, Groups A,B,C,D1
Class l, Zone 2, Groups IIC, llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3, 4, 4X; IP66
Class I, Zone 2 AEx nAnR2
Class I, Zone 2 Ex nR2
NEW!
TWO BATTERY
MODELS
Standard Materials
Ballast tank and splice box – copper-free
aluminum alloy with baked powder
epoxy/polyester finish, electrostatically
applied. External hardware – 316 SS.
Compliances
UL1598 Standard for luminaires
UL1598A Marine type luminaire
UL-844 Standard for lighting fixtures for
hazardous locations
CSA C22.2 no. 137-M1981 electric lumi-
naries for use in hazardous locations
Replaces
DEB/VEB/VEQ
Series
Options
RD - Red paint housing, mount, guard
(VMAG17, VMAG25S)
F, FF - Factory fused; F = Single fuse for
120V, 230V 50 Hz (VExQ); FF = Double
fuse for 208V, 220V 60 Hz, 240V
UL-924 Emergency Lighting
Enclosed and gasketed
NEMA 3, 4X IP66
UL 60079-15 - Electrical apparatus for
Explosive Gas Atmospheres with Type of
Protection “n” (Restricted Breathing and
non-sparking).
Accessories
VEXA—100B 3–sided Exit sign: (Use w/o
guard)
VEXA—400 4–sided Exit sign: (Use w/o
guard)
VMPSD—40 Dome and VMPA—40 Angle
Reflectors (see page L118)
XCS-OB3-PTT “Push-To-Test” n.c
Stantion (order SWB box separately)
1See Hazardous Application Data page L205 for limitations.
2NR Restricted breathing (VExx) for lower T-Codes. See page L54.
Note: xE3x dimensions are the same as VM3
xE4x dimensions are the same as VM4
See L___ for more information
Photometrics similar to VQ1F Series.
See page L150.
D E 3 B | V E 3 B | V E 3 Q
DE4B | VE4B | VE4Q SERIES LIGHTING
CATALOG ORDERING LOGIC
L199
L199
L
CertiLite®ECatalog Number Logic; 13-84W Battery Backed (Compact Fluorscent) Fixtures
DE3B 5-1/2" Emerg. Bi-Pin C2D1
DE4B 7-3/4"
VE3B 5-1/2" Emerg. Bi-Pin C1D2, C2D1
VE4B 7-3/4"
VE3Q 5-1/2" Emerg. Quad-Pin C1D2, C2D1
VE4Q 7-3/4"
AC Lamps Powered
00 - Emergency Only
13 - 1 x 13 Bi-Pin
18 - 1 x 18 Quad-Pin
26 - 1 x 26 Quad-Pin
32 - 1 x 32 Quad-Pin
42 - 1 x 42 Quad-Pin
26 - 2 x 13 Bi-Pin
36 - 2 x 18 Quad-Pin
52 - 2 x 26 Quad-Pin
64 - 2 x 32 Quad-Pin
84 - 2 x 42 Quad-Pin
DC Lamps Powered
(also = # of batteries)
13 - 1 x 13 Bi-Pin
18 - 1 x 18 Quad-Pin
26 - 1 x 26 Quad-Pin
32 - 1 x 32 Quad-Pin
42 - 1 x 42 Quad-Pin
26 - 2 x 13 Bi-Pin
36 - 2 x 18 Quad-Pin
52 - 2 x 26 Quad-Pin
64 - 2 x 32 Quad-Pin
84 - 2 x 42 Quad-Pin
Voltage
1—120V
E30—120-277VAC Quad-Pin Normal &
Emergency or Emergency Only
E01—120V Bi-Pin Normal & Emergency
E04—277V Bi-Pin Normal & Emergency
E10—120/277V Bi-Pin Emergency Only
Guard
G—Guard
N—Without Guard
Options
RD—Red Tank/Mount/Guard
NR—Ex nA nR Restricted
Breathing7
F—Single fuse5
FF—Double fuse5
TBx—Terminal Blocks
P1—Photo Cell Factory 120V6
P2—Photo Cell Factory 208-
277V6
QD—Quick Disconnect9
CP—Component Pack
AS—Assembled fixture
AN—Assembled no lamps
Optic
GL—Globe (VQ1F, VQ2F)
R1—Type I Glass Refractor
R3—Type III Glass Refractor (Tank
4)
R5—Type V Glass Refractor
ER—Enclosed Reflector (Tank 4)
EP—Poylcarbonate Shielded
Enclosed Reflector (VQ2F)8
S2—Type II 12" Spin-Top Refractor
S8—Type V 8" Spin-Top Refractor
(Tank 3)
S5—Type V 12" Spin-Top Refractor
P5—Type V 12" Plastic Spin-Top
Refractor (Tank 3)
FG—Silicone3Coated Globe
TG—Teflon®4Coated Globe
T1—Teflon®4Coated Globe Type I
Glass Refractor
T3—Teflon®4Coated Globe Type III
Glass Refractor (Tank 4)
T5—Teflon®4Coated Globe Type V
Glass Refractor
T2—Teflon®4Coated Type II 12"
Spin-Top Refractor
T8—Teflon®4Coated Type V 8"
Spin-Top Refractor (Tank 3)
TV—Teflon®4Coated Type V 12"
Spin-Top Refractor
Entry (Mounts available)
2—3/4" NPT (A,B,C,X)
3—1" NPT (A,B,C,X)
4—1 1/4" NPT (D,S)
5—1 1/2" NPT (D,S)
6—3/4" NPT 5-Hub (X)
7—1" NPT 5-Hub (X)
8—M20 4-Hub (X)
9—M20 5-Hub (X)
Z—EZ Mount Adapter1
N—None (mount ordered
separately)2
VE4Q 84 84 E30 A 3 R1 G (NR7)
1Completes as “EZ”, conduit mounting boxes ordered separately - See L83.
2NN mount ordered separately.
3Silicone coated globe for additional impact protection.
4Teflon®is a registered trademark of DuPont, Inc.
5Fusing not for Marine or Canadian installations
6Photo cells for Class I, Div. 2 only. VExx Models
7Restricted Breathing - See L54 for more information.
8Not for use with wall or straight (90°) Stanchion.
9QD = Quick Disconnect. Allows easy tank removal for maintenance.
Electrician simply unplugs de-energized tank from supply circuit.
Bi-Pin & Quad-Pin cannot be mixed. Wattages cannot be mixed
e.g. 4232 or 6484.
Mounting Type
A—Pendant
X—Ceiling
B—Wall Bracket
C—Cone Top
E—EZ Mount Adapter1
D—Stanchion 25°
S—Stanchion Straight 90°
N—None (mount ordered
separately)2
D E 3 B | V E 3 B | V E 3 Q
DE4B | VE4B | VE4Q SERIES LIGHTING
COMPACT FLUORESCENT EMERGENCY FIXTURES
L200
13 - 84 WATT EMERGENCY FIXTURES - 3/4" PENDANT (** CEILING - WALL - CONE) COMPACT FLUORESCENT
DESCRIPTION
VOLTAGE
WATTS/ TYPE
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
8" SPIN-TOP TYPE
V REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE
V REFRACTOR
& GUARD
13W (1x13) Emer Only 120V or 277 VAC DE3B0013E10A2GLG DE3B0013E10A2R5G DE3B0013E10A2S8G DE4B0013E10A2GLG DE4B0013E10A2R5G DE4B0013E10A2S5G
26W (2x13) Emer Only DE3B0026E10A2GLG DE3B0026E10A2R5G DE3B0026E10A2S8G DE4B0026E10A2GLG DE4B0026E10A2R5G DE4B0026E10A2S5G
13W (1x13) Normal 120VAC 60Hz DE3B1313E01A2GLG DE3B1313E01A2R5G DE3B1313E01A2S8G DE4B1313E01A2GLG DE4B1313E01A2R5G DE4B1313E01A2S5G
13W (1x13) Emergency 277VAC 60Hz DE3B1313E04A2GLG DE3B1313E04A2R5G DE3B1313E04A2S8G DE4B1313E04A2GLG DE4B1313E04A2R5G DE4B1313E04A2S5G
26W (2x13) Normal 120VAC 60Hz DE3B2613E01A2GLG DE3B2613E01A2R5G DE3B2613E01A2S8G DE4B2613E01A2GLG DE4B2613E01A2R5G DE4B2613E01A2S5G
13W (1x13) Emergency 277VAC 60Hz DE3B2613E04A2GLG DE3B2613E04A2R5G DE3B2613E04A2S8G DE4B2613E04A2GLG DE4B2613E04A2R5G DE4B2613E04A2S5G
26W (2x13) Normal 120VAC 60Hz DE3B2626E01A2GLG DE3B2626E01A2R5G DE3B2626E01A2S8G DE4B2626E01A2GLG DE4B2626E01A2R5G DE4B2626E01A2S5G
26W (2x13) Emergency 277VAC 60Hz DE3B2626E04A2GLG DE3B2626E04A2R5G DE3B2626E04A2S8G DE4B2626E04A2GLG DE4B2626E04A2R5G DE4B2626E04A2S5G
13W (1x13) Emer Only 120V or 277VAC VE3B0013E10A2GLG VE3B0013E10A2R5G VE3B0013E10A2S8G VE4B0013E10A2GLG VE4B0013E10A2R5G VE4B0013E10A2S5G
26W (2x13) Emer Only VE3B0026E10A2GLG VE3B0026E10A2R5G VE3B0026E10A2S8G VE4B0026E10A2GLG VE4B0026E10A2R5G VE4B0026E10A2S5G
13W (1x13) Normal 120VAC 60Hz VE3B1313E01A2GLG VE3B1313E01A2R5G VE3B1313E01A2S8G VE4B1313E01A2GLG VE4B1313E01A2R5G VE4B1313E01A2S5G
13W (1x13) Emergency 277VAC 60Hz VE3B1313E04A2GLG VE3B1313E04A2R5G VE3B1313E04A2S8G VE4B1313E04A2GLG VE4B1313E04A2R5G VE4B1313E04A2S5G
26W (2x13) Normal 120VAC 60Hz VE3B2613E01A2GLG VE3B2613E01A2R5G VE3B2613E01A2S8G VE4B2613E01A2GLG VE4B2613E01A2R5G VE4B2613E01A2S5G
13W (1x13) Emergency 277VAC 60Hz VE3B2613E04A2GLG VE3B2613E04A2R5G VE3B2613E04A2S8G VE4B2613E04A2GLG VE4B2613E04A2R5G VE4B2613E04A2S5G
26W (2x13) Normal 120VAC 60Hz VE3B2626E01A2GLG VE3B2626E01A2R5G VE3B2626E01A2S8G VE4B2626E01A2GLG VE4B2626E01A2R5G VE4B2626E01A2S5G
26W (2x13) Emergency 277VAC 60Hz VE3B2626E04A2GLG VE3B2626E04A2R5G VE3B2626E04A2S8G VE4B2626E04A2GLG VE4B2626E04A2R5G VE4B2626E04A2S5G
18W (1x18) Emer Only 120 to 277 50-60Hz VE3Q0018E30A2GLG VE3Q0018E30A2R5G VE3Q0018E30A2S8G VE4Q0018E30A2GLG VE4Q0018E30A2R5G VE4Q0018E30A2S5G
36W (2x18) Emer Only 120 to 277 50-60Hz VE3Q0036E30A2GLG VE3Q0036E30A2R5G VE3Q0036E30A2S8G VE4Q0036E30A2GLG VE4Q0036E30A2R5G VE4Q0036E30A2S5G
18W (1x18) Normal/Emer 120 to 277 50-60Hz VE3Q1818E30A2GLG VE3Q1818E30A2R5G VE3Q1818E30A2S8G VE4Q1818E30A2GLG VE4Q1818E30A2R5G VE4Q1818E30A2S5G
36W (2x18) Normal 120 to 277 50-60Hz VE3Q3618E30A2GLG VE3Q3618E30A2R5G VE3Q3618E30A2S8G VE4Q3618E30A2GLG VE4Q3618E30A2R5G VE4Q3618E30A2S5G
18W (1x18) Emergency
36W (2x18) Normal/Emer 120 to 277 50-60Hz VE3Q3636E30A2GLG VE3Q3636E30A2R5G VE3Q3636E30A2S8G VE4Q3636E30A2GLG VE4Q3636E30A2R5G VE4Q3636E30A2S5G
26W (1x26) Emer Only 120 to 277 50-60Hz VE3Q0026E30A2GLG VE3Q0026E30A2R5G VE3Q0026E30A2S8G VE4Q0026E30A2GLG VE4Q0026E30A2R5G VE4Q0026E30A2S5G
52W (2x26) Emer Only 120 to 277 50-60Hz VE3Q0052E30A2GLG VE3Q0052E30A2R5G VE3Q0052E30A2S8G VE4Q0052E30A2GLG VE4Q0052E30A2R5G VE4Q0052E30A2S5G
26W (1x26) Normal/Emer 120 to 277 50-60Hz VE3Q2626E30A2GLG VE3Q2626E30A2R5G VE3Q2626E30A2S8G VE4Q2626E30A2GLG VE4Q2626E30A2R5G VE4Q2626E30A2S5G
52W (2x26) Normal 120 to 277 50-60Hz VE3Q5226E30A2GLG VE3Q5226E30A2R5G VE3Q5226E30A2S8G VE4Q5226E30A2GLG VE4Q5226E30A2R5G VE4Q5226E30A2S5G
26W (1x26) Emergency
52W (2x26) Normal/Emer 120 to 277 50-60Hz VE3Q5252E30A2GLG VE3Q5252E30A2R5G VE3Q5252E30A2S8G VE4Q5252E30A2GLG VE4Q5252E30A2R5G VE4Q5252E30A2S5G
32W (1x32) Emer Only 120 to 277 50-60Hz VE3Q0032E30A2GLG VE3Q0032E30A2R5G VE3Q0032E30A2S8G VE4Q0032E30A2GLG VE4Q0032E30A2R5G VE4Q0032E30A2S5G
64W (2x32) Emer Only 120 to 277 50-60Hz VE3Q0064E30A2GLG VE3Q0064E30A2R5G VE3Q0064E30A2S8G VE4Q0064E30A2GLG VE4Q0064E30A2R5G VE4Q0064E30A2S5G
32W (1x32) Normal/Emer 120 to 277 50-60Hz VE3Q3232E30A2GLG VE3Q3232E30A2R5G VE3Q3232E30A2S8G VE4Q3232E30A2GLG VE4Q3232E30A2R5G VE4Q3232E30A2S5G
64W (2x32) Normal 120 to 277 50-60Hz VE3Q6432E30A2GLG VE3Q6432E30A2R5G VE3Q6432E30A2S8G VE4Q6432E30A2GLG VE4Q6432E30A2R5G VE4Q6432E30A2S5G
32W (1x32) Emergency
64W (2x32) Normal/Emer 120 to 277 50-60Hz VE3Q6464E30A2GLG VE3Q6464E30A2R5G VE3Q6464E30A2S8G VE4Q6464E30A2GLG VE4Q6464E30A2R5G VE4Q6464E30A2S5G
42W (1x42) Emer Only 120 to 277 50-60Hz VE3Q0042E30A2GLG VE3Q0042E30A2R5G VE3Q0042E30A2S8G VE4Q0042E30A2GLG VE4Q0042E30A2R5G VE4Q0042E30A2S5G
84W (2x42) Emer Only 120 to 277 50-60Hz VE3Q0084E30A2GLG VE3Q0084E30A2R5G VE3Q0084E30A2S8G VE4Q0084E30A2GLG VE4Q0084E30A2R5G VE4Q0084E30A2S5G
42W (1x42) Normal/Emer 120 to 277 50-60Hz VE3Q4242E30A2GLG VE3Q4242E30A2R5G VE3Q4242E30A2S8G VE4Q4242E30A2GLG VE4Q4242E30A2R5G VE4Q4242E30A2S5G
84W (2x42) Normal 120 to 277 50-60Hz VE3Q8442E30A2GLG VE3Q8442E30A2R5G VE3Q8442E30A2S8G VE4Q8442E30A2GLG VE4Q8442E30A2R5G VE4Q8442E30A2S5G
42W (1x42) Emergency
84W (2x42) Normal/Emer 120 to 277 50-60Hz VE3Q8484E30A2GLG VE3Q8484E30A2R5G VE3Q8484E30A2S8G VE4Q8484E30A2GLG VE4Q8484E30A2R5G VE4Q8484E30A2S5G
1See hazardous location data pages L204 - L205 for application suitability
2xE3x models use 5-1/2" CertiLite®V VM optics accessories; xE4x models use 7-3/4" VM optics accessories.
** Grid is populated with 3/4" Pendant models with Optic Guards, to omit guard change last G to N e.g. DE3B0013E10A2GLN
- 3/4" Ceiling models change A2 to X2 - 3/4" Wall Bracket models change A2 to B2
- 3/4" Cone-top models change A2 to C2 - For 1" change to A3, X3, B3, or C3
Class II Div 1, N4X, IP66 1
See Page L198 for Suitabilities1
Tank 3 Pendant
w/ 5-1/2"
Globe & Guard
Tank 4 Ceiling
w/ 7-3/4"
Globe & Guard
Tank 3 Wall
w/ 5-1/2"
Refractor & Guard
Tank 4 Cone
w/ 7-3/4"
Globe & Guard
Class I Div 2, Class II Div 1, N4X, IP66 1
D E 3 B | V E 3 B | V E 3 Q
DE4B | VE4B | VE4Q SERIES LIGHTING
COMPACT FLUORESCENT EMERGENCY FIXTURES
L201
L201
L
13 - 84 WATT EMERGENCY FIXTURES - 25° STANCHION (** STRAIGHT STANCHION, EZ ADAPTER) COMPACT FLUORESCENT
DESCRIPTION
VOLTAGE
WATTS/ TYPE
5-1/2" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
8" SPIN-TOP TYPE
V REFRACTOR
& GUARD
7-3/4" OPTIC THREAD SIZE 2
GLOBE
& GUARD
TYPE V GLASS
REFRACTOR
& GUARD
12" SPIN-TOP TYPE
V REFRACTOR
& GUARD
13W (1x13) Emer Only 120V or 277VAC DE3B0013E10D5GLG DE3B0013E10D5R5G DE3B0013E10D5S8G DE4B0013E10D5GLG DE4B0013E10D5R5G DE4B0013E10D5S5G
26W (2x13) Emer Only DE3B0026E10D5GLG DE3B0026E10D5R5G DE3B0026E10D5S8G DE4B0026E10D5GLG DE4B0026E10D5R5G DE4B0026E10D5S5G
13W (1x13) Normal 120VAC 60Hz DE3B1313E01D5GLG DE3B1313E01D5R5G DE3B1313E01D5S8G DE4B1313E01D5GLG DE4B1313E01D5R5G DE4B1313E01D5S5G
13W (1x13) Emergency 277VAC 60Hz DE3B1313E04D5GLG DE3B1313E04D5R5G DE3B1313E04D5S8G DE4B1313E04D5GLG DE4B1313E04D5R5G DE4B1313E04D5S5G
26W (2x13) Normal 120VAC 60Hz DE3B2613E01D5GLG DE3B2613E01D5R5G DE3B2613E01D5S8G DE4B2613E01D5GLG DE4B2613E01D5R5G DE4B2613E01D5S5G
13W (1x13) Emergency 277VAC 60Hz DE3B2613E04D5GLG DE3B2613E04D5R5G DE3B2613E04D5S8G DE4B2613E04D5GLG DE4B2613E04D5R5G DE4B2613E04D5S5G
26W (2x13) Normal 120VAC 60Hz DE3B2626E01D5GLG DE3B2626E01D5R5G DE3B2626E01D5S8G DE4B2626E01D5GLG DE4B2626E01D5R5G DE4B2626E01D5S5G
26W (2x13) Emergency 277VAC 60Hz DE3B2626E04D5GLG DE3B2626E04D5R5G DE3B2626E04D5S8G DE4B2626E04D5GLG DE4B2626E04D5R5G DE4B2626E04D5S5G
13W (1x13) Emer Only 120V or 277VAC VE3B0013E10D5GLG VE3B0013E10D5R5G VE3B0013E10D5S8G VE4B0013E10D5GLG VE4B0013E10D5R5G VE4B0013E10D5S5G
26W (2x13) Emer Only VE3B0026E10D5GLG VE3B0026E10D5R5G VE3B0026E10D5S8G VE4B0026E10D5GLG VE4B0026E10D5R5G VE4B0026E10D5S5G
13W (1x13) Normal 120VAC 60Hz VE3B1313E01D5GLG VE3B1313E01D5R5G VE3B1313E01D5S8G VE4B1313E01D5GLG VE4B1313E01D5R5G VE4B1313E01D5S5G
13W (1x13) Emergency 277VAC 60Hz VE3B1313E04D5GLG VE3B1313E04D5R5G VE3B1313E04D5S8G VE4B1313E04D5GLG VE4B1313E04D5R5G VE4B1313E04D5S5G
26W (2x13) Normal 120VAC 60Hz VE3B2613E01D5GLG VE3B2613E01D5R5G VE3B2613E01D5S8G VE4B2613E01D5GLG VE4B2613E01D5R5G VE4B2613E01D5S5G
13W (1x13) Emergency 277VAC 60Hz VE3B2613E04D5GLG VE3B2613E04D5R5G VE3B2613E04D5S8G VE4B2613E04D5GLG VE4B2613E04D5R5G VE4B2613E04D5S5G
26W (2x13) Normal 120VAC 60Hz VE3B2626E01D5GLG VE3B2626E01D5R5G VE3B2626E01D5S8G VE4B2626E01D5GLG VE4B2626E01D5R5G VE4B2626E01D5S5G
26W (2x13) Emergency 277VAC 60Hz VE3B2626E04D5GLG VE3B2626E04D5R5G VE3B2626E04D5S8G VE4B2626E04D5GLG VE4B2626E04D5R5G VE4B2626E04D5S5G
18W (1x18) Emer Only 120 to 277 50-60Hz VE3Q0018E30D5GLG VE3Q0018E30D5R5G VE3Q0018E30D5S8G VE4Q0018E30D5GLG VE4Q0018E30D5R5G VE4Q0018E30D5S5G
36W (2x18) Emer Only 120 to 277 50-60Hz VE3Q0036E30D5GLG VE3Q0036E30D5R5G VE3Q0036E30D5S8G VE4Q0036E30D5GLG VE4Q0036E30D5R5G VE4Q0036E30D5S5G
18W (1x18) Normal/Emer 120 to 277 50-60Hz VE3Q1818E30D5GLG VE3Q1818E30D5R5G VE3Q1818E30D5S8G VE4Q1818E30D5GLG VE4Q1818E30D5R5G VE4Q1818E30D5S5G
36W (2x18) Normal 120 to 277 50-60Hz VE3Q3618E30D5GLG VE3Q3618E30D5R5G VE3Q3618E30D5S8G VE4Q3618E30D5GLG VE4Q3618E30D5R5G VE4Q3618E30D5S5G
18W (1x18) Emergency
36W (2x18) Normal/Emer 120 to 277 50-60Hz VE3Q3636E30D5GLG VE3Q3636E30D5R5G VE3Q3636E30D5S8G VE4Q3636E30D5GLG VE4Q3636E30D5R5G VE4Q3636E30D5S5G
26W (1x26) Emer Only 120 to 277 50-60Hz VE3Q0026E30D5GLG VE3Q0026E30D5R5G VE3Q0026E30D5S8G VE4Q0026E30D5GLG VE4Q0026E30D5R5G VE4Q0026E30D5S5G
52W (2x26) Emer Only 120 to 277 50-60Hz VE3Q0052E30D5GLG VE3Q0052E30D5R5G VE3Q0052E30D5S8G VE4Q0052E30D5GLG VE4Q0052E30D5R5G VE4Q0052E30D5S5G
26W (1x26) Normal/Emer 120 to 277 50-60Hz VE3Q2626E30D5GLG VE3Q2626E30D5R5G VE3Q2626E30D5S8G VE4Q2626E30D5GLG VE4Q2626E30D5R5G VE4Q2626E30D5S5G
52W (2x26) Normal 120 to 277 50-60Hz VE3Q5226E30D5GLG VE3Q5226E30D5R5G VE3Q5226E30D5S8G VE4Q5226E30D5GLG VE4Q5226E30D5R5G VE4Q5226E30D5S5G
26W (1x26) Emergency
52W (2x26) Normal/Emer 120 to 277 50-60Hz VE3Q5252E30D5GLG VE3Q5252E30D5R5G VE3Q5252E30D5S8G VE4Q5252E30D5GLG VE4Q5252E30D5R5G VE4Q5252E30D5S5G
32W (1x32) Emer Only 120 to 277 50-60Hz VE3Q0032E30D5GLG VE3Q0032E30D5R5G VE3Q0032E30D5S8G VE4Q0032E30D5GLG VE4Q0032E30D5R5G VE4Q0032E30D5S5G
64W (2x32) Emer Only 120 to 277 50-60Hz VE3Q0064E30D5GLG VE3Q0064E30D5R5G VE3Q0064E30D5S8G VE4Q0064E30D5GLG VE4Q0064E30D5R5G VE4Q0064E30D5S5G
32W (1x32) Normal/Emer 120 to 277 50-60Hz VE3Q3232E30D5GLG VE3Q3232E30D5R5G VE3Q3232E30D5S8G VE4Q3232E30D5GLG VE4Q3232E30D5R5G VE4Q3232E30D5S5G
64W (2x32) Normal 120 to 277 50-60Hz VE3Q6432E30D5GLG VE3Q6432E30D5R5G VE3Q6432E30D5S8G VE4Q6432E30D5GLG VE4Q6432E30D5R5G VE4Q6432E30D5S5G
32W (1x32) Emergency
64W (2x32) Normal/Emer 120 to 277 50-60Hz VE3Q6464E30D5GLG VE3Q6464E30D5R5G VE3Q6464E30D5S8G VE4Q6464E30D5GLG VE4Q6464E30D5R5G VE4Q6464E30D5S5G
42W (1x42) Emer Only 120 to 277 50-60Hz VE3Q0042E30D5GLG VE3Q0042E30D5R5G VE3Q0042E30D5S8G VE4Q0042E30D5GLG VE4Q0042E30D5R5G VE4Q0042E30D5S5G
84W (2x42) Emer Only 120 to 277 50-60Hz VE3Q0084E30D5GLG VE3Q0084E30D5R5G VE3Q0084E30D5S8G VE4Q0084E30D5GLG VE4Q0084E30D5R5G VE4Q0084E30D5S5G
42W (1x42) Normal/Emer 120 to 277 50-60Hz VE3Q4242E30D5GLG VE3Q4242E30D5R5G VE3Q4242E30D5S8G VE4Q4242E30D5GLG VE4Q4242E30D5R5G VE4Q4242E30D5S5G
84W (2x42) Normal 120 to 277 50-60Hz VE3Q8442E30D5GLG VE3Q8442E30D5R5G VE3Q8442E30D5S8G VE4Q8442E30D5GLG VE4Q8442E30D5R5G VE4Q8442E30D5S5G
42W (1x42) Emergency
84W (2x42) Normal/Emer 120 to 277 50-60Hz VE3Q8484E30D5GLG VE3Q8484E30D5R5G VE3Q8484E30D5S8G VE4Q8484E30D5GLG VE4Q8484E30D5R5G VE4Q8484E30D5S5G
1See hazardous location data pages L204 - L205 for application suitability
2xE3x models use 5-1/2" CertiLite®V VM optics accessories; xE4x models use 7-3/4" VM optics accessories.
** Grid is populated with 1-1/2" 25° Stanchion models with Optic Guards, to omit guard change last G to N e.g. DE3B0013E10A2GLN
- 1-1/2" Straight models change D5 to S5 - 1-1/4" Stanchions change “5” to “4” e.g. D4 or S4
- EZ adapter models require EZ Mounts to energize, see L83 for more information
Class II Div 1, N4X, IP66 1Class I Div 2, Class II Div 1, N4X, IP66 1
See Page L198 for Suitabilities1
Tank 4 Stanchion Straight
w/ 7-3/4"
Refractor & Guard
Tank 3 EZ Adapter
w/ 5-1/2"
Refractor & Guard
Tank 1 Stanchion 25°
w/5-1/2"
Globe & Guard
D E 3 B | V E 3 B | V E 3 Q
DE4B | VE4B | VE4Q SERIES LIGHTING
COMPONENTS
L202
L202
BALLAST-BATTERY TANKS WITH LAMPS
DESCRIPTION
VOLTAGE
WATTS/ TYPE 5-1/2" OPTIC THREAD SIZE 27-3/4" OPTIC THREAD SIZE 3
INITIAL LUMENS
NORMAL AC EMER. BATTERY
13W (1 x 13) Emer Only 120V or 277VAC DE3B0013E10 DE4B0013E10 — 625
26W (2 x 13) Emer Only DE3B0026E10 DE4B0026E10 1250
13W (1x13) Normal 120VAC 60Hz DE3B1313E01 DE4B1313E01 825 625
13W (1x13) Emergency 277VAC 60Hz DE3B1313E04 DE4B1313E04 825 625
26W (2x13) Normal 120VAC 60Hz DE3B2613E01 DE4B2613E01 1650 625
13W (1x13) Emergency 277VAC 60Hz DE3B2613E04 DE4B2613E04 1650 625
26W (2x13) Normal 120VAC 60Hz DE3B2626E01 DE4B2626E01 1650 1250
26W (2x13) Emergency 277VAC 60Hz DE3B2626E04 DE4B2626E04 1650 1250
13W (1 x 13) Emer Only 120V or 277VAC VE3B0013E10 VE4B0013E10 — 625
26W (2 x 13) Emer Only VE3B0026E10 VE4B0026E10 1250
13W (1x13) Normal 120VAC 60Hz VE3B1313E01 VE4B1313E01 825 625
13W (1x13) Emergency 277VAC 60Hz VE3B1313E04 VE4B1313E04 825 625
26W (2x13) Normal 120VAC 60Hz VE3B2613E01 VE4B2613E01 1650 625
13W (1x13) Emergency 277VAC 60Hz VE3B2613E04 VE4B2613E04 1650 625
26W (2x13) Normal 120VAC 60Hz VE3B2626E01 VE4B2626E01 1650 1250
26W (2x13) Emergency 277VAC 60Hz VE3B2626E04 VE4B2626E04 1650 1250
18W (1 x 18) Emer Only 120 to 277 50-60Hz VE3Q0018E30 VE4Q0018E30 400
36W (2 x 18) Emer Only 120 to 277 50-60Hz VE3Q0036E30 VE4Q0036E30 800
18W (1x18) Normal/Emer 120 to 277 50-60Hz VE3Q1818E30 VE4Q1818E30 1200 400
36W (2x18) Normal 120 to 277 50-60Hz VE3Q3618E30 VE4Q3618E30 2400 400
18W (1x18) Emergency
36W (2x18) Normal/Emer 120 to 277 50-60Hz VE3Q3636E30 VE4Q3636E30 2400 800
26W 1 x 26 Emer Only 120 to 277 50-60Hz VE3Q0026E30 VE4Q0026E30 425
52W 2 x 26 Emer Only 120 to 277 50-60Hz VE3Q0052E30 VE4Q0052E30 850
26W (1x26) Normal/Emer 120 to 277 50-60Hz VE3Q2626E30 VE4Q2626E30 1800 425
52W (2x26) Normal 120 to 277 50-60Hz VE3Q5226E30 VE4Q5226E30 3600 425
26W (1x26) Emergency
52W (2x26) Normal/Emer 120 to 277 50-60Hz VE3Q5252E30 VE4Q5252E30 3600 850
32W (1 x 32) Emer Only 120 to 277 50-60Hz VE3Q0032E30 VE4Q0032E30 525
64W (2 x 32) Emer Only 120 to 277 50-60Hz VE3Q0064E30 VE4Q0064E30 1050
32W (1x32) Normal/Emer 120 to 277 50-60Hz VE3Q3232E30 VE4Q3232E30 2400 525
64W (2x32) Normal 120 to 277 50-60Hz VE3Q6432E30 VE4Q6432E30 4800 525
32W (1x32) Emergency
64W (2x32) Normal/Emer 120 to 277 50-60Hz VE3Q6464E30 VE4Q6464E30 4800 1050
42W (1 x 42) Emer Only 120 to 277 50-60Hz VE3Q0042E30 VE4Q0042E30 700
84W (2 x 42) Emer Only 120 to 277 50-60Hz VE3Q0084E30 VE4Q0084E30 1400
42W (1x42) Normal/Emer 120 to 277 50-60Hz VE3Q4242E30 VE4Q4242E30 3200 700
84W (2x42) Normal 120 to 277 50-60Hz VE3Q8442E30 VE4Q8442E30 6400 700
42W (1x42) Emergency
84W (2x42) Normal/Emer 120 to 277 50-60Hz VE3Q8484E30 VE4Q8484E30 6400 1400
1See hazardous location data pages L204 - L205 for application suitability
2See VM3 5-1/2" Optics Page L95; xE3x series use VM mounts and accessories
3See VM4 7-3/4" Optics Page L95; xE4x series use VM mounts and accessories
Class II Div 1, N4X, IP66 1Class I Div 2, Class II Div 1, N4X, IP66 1
See Page L198 for Suitabilities1
Tank 3
5-1/2" Optic Thread Size
Tank 4
7-3/4" Optic Thread Size
D E 3 B | V E 3 B | V E 3 Q
DE4B | VE4B | VE4Q SERIES LIGHTING
COMPONENTS
L203
L
MOUNTING SPLICE BOXES
3/4"
1"
1-1/4"
1-1/2"
M-20
HUB SIZE
VMA2B
VMA3B
PENDANT
VMF2B
VMF3B
FLEXIBLE PENDANT
VMX2B
VMX3B
VMX8B**
CEILING 4 HUB
VMX6B
VMX7B
VMX9B
CEILING 5 HUB
VMB2B
VMB3B
WALL
VMC2B
VMC3B
CONE TOP
VMD4B
VMD5B
25 DEGREE STANCHION
VMS4B
VMS5B
90 DEGREE STANCHION
CATALOG NUMBER
Pendant Ceiling
Flexible Pendant
25° Stanchion
Cone Top
Straight Stanchion EZ Adapter* VMEZA
*VMEZA is used between a ballast tank and an EZ mount-ordered separately. See L94 for more information.
**VMX8B furnished with 3 non-metallic plugs.
VMAG17 VMRWG8
VMER40
VMG40
VMG25
VMAG25S VMAG40S
VMR255
VMR253
VMR251
VZRG1550 VZRG2550
VZRG2520
VZRP175
VMEP40
VMAG17
VMR175
VMR171
VMG17
VMRWGS VMAG25S VMERG
VZRG4050
VZRG4020
VMRWG8
O
P
T
I
C
S
G
U
A
R
D
S
VMAGBC
Bottom Closure for
VMAG25S/VMAG40S
REFLECTORS
HRD400
VMPSD40 VMPA40 HRD400ALZ
Standard Dome
Fiberglass White
Reflector Dia: 16"
30OAngle
Fiberglass White
Reflector Dia: 16"
Deep Aluminum
White Reflector
Dia: 21"
Deep Aluminum
Anodized Reflector
Dia: 21"
OPTICS & GUARDS
DESCRIPTION
Globe (glass)
Refractor (all glass) Type V
Refractor (all glass) Type I
Refractor (all glass) Type III
Refractor (spin top glass) 8" Type V
Refractor (spin top glass) 12" Type V
Refractor (spin top glass) 12" Type II
Refractor (spin top plastic) 12" Type V
Enclosed Reflector (glass lens)
Enclosed Reflector (plastic lens)
OPTICS
VMG17
VMR175
VMR171
VZRG1550
VZRG2550
VZRG2520
VZRP175
GUARD
VMAG17
VMAG17
VMAG17
VMRWG8
VMRWG
VMRWG
VMRWG
OPTICS
VMG25
VMR255
VMR251
VMR253
VZRG4050
VZRG4020
VMER40
VMEP40
GUARD
VMAG25S
VMAG25S
VMAG25S
VMAG25S
VMRWG
VMRWG
VMERG
7-3/4" Optic Thread Size
5-1/2" Optic Thread Size
DE4B/VE4B/VE4Q
7-3/4" Optic
DE3B/VE3B/VE3Q
5-1/2" Optic
See Ordering
Information on
Page L83 for EZ
Mounting Boxes
D E 3 B | V E 3 B | V E 3 Q
DE4B | VE4B | VE4Q SERIES LIGHTING
COMPONENTS/APPLICATION DATA
L204
L204
FEATURES-SPECIFICATIONS
VEXA400 4-Sided EXIT for all Models
Letters are 3/4" x 8" Red on white
Unit includes 3 EXIT Faces and
2 Blank for Maximum Flexibility
Dimensions: 14.56" x 9.22"
VEXA100B 3-Sided EXIT Accessory for
xE3x models
Letters are 3/4" x 6" Red on White
14.2"
8.1"
14.2"
9.25" 6"
EXIT
VEXA100B Exit Accessory Dimensions
See pages L94-L96 for VM mounts,
optics and accessories including
reflectors and suspension devices.
REPLACEMENT BATTERY UNITS
13W BI-PIN KFBP6 FOR DEXB
13W BI-PIN KFBP5 FOR VEXB
18/26/32/42W QUAD-PIN KFBP7
CATALOG NUMBER
WATTAGE/TYPE
BALLAST DATA *
26WATT (1X13) 120 / 277 0.39/.35 0.3 16 NPF
26WATT (2X13) 120 / 277 0.78/.70 0.6 32 NPF
18 WATT (1X18) 120 THROUGH 277 .16@120V /.07 @277V 19 HPF
26WATT (1X26) 120 THROUGH 277 .27@120V /.13 @277V 29 HPF ELECTRONIC
32WATT (1X32) 120 THROUGH 277 .31@120V /.15 @277V 36 HPF ELECTRONIC
42WATT (1X42) 120 THROUGH 277 .37@120V /.17 @277V 46 HPF ELECTRONIC
36 WATT (2X18) 120 THROUGH 277 .32@120V /.14 @277V 38 HPF
52WATT (2X26) 120 THROUGH 277 .54@120V /.26 @277V 58 HPF ELECTRONIC
64WATT (2X32) 120 THROUGH 277 .62@120V /.30 @277V 72 HPF ELECTRONIC
84WATT (2X42) 120 THROUGH 277 .74@120V /.34 @277V 92 HPF ELECTRONIC
LAMP WATTS VOLTAGE AC START OPERATING INPUT WATTS BALLAST CIRCUIT REGULATION
REPLACEMENT LAMPS
13W BI-PIN MPL-13
26W QUAD-PIN MQL18
26W QUAD-PIN MQL26
32W QUAD-PIN MQL32
42W QUAD-PIN MQL42
CATALOG NUMBER
WATTAGE/TYPE
* Add per battery prox .6 amp for charging current. Prox 24 hours to full recharge after full discharge.
APPLICATION DATA
DE3B0013 1 X 13 40 T3B (EFG) T3B (EFG) 60
DE3B0026 2 X 13 40 T3B (EFG) T3C (EFG) 60
DE3B1313 1 X 13 40 T3B (EFG) T3C (EFG) 60
DE3B2613 2 X 13 40 T3B (EFG) T3C (EFG) 60
DE3B2626 2 X 13 40 T3B (EFG) T3C (EFG) 60
DE4B0013 1 X 13 40 T4A (EFG) T4A (EFG) 60
DE4B0026 2 X 13 40 T4A (EFG) T4A (EFG) 60
DE4B1313 1 X 13 40 T4A (EFG) T4A (EFG) 60
DE4B2613 2 X 13 40 T4A (EFG) T4A (EFG) 60
DE4B2626 2 X 13 40 T4A (EFG) T4A (EFG) 60
1T-codes for Refractors include VMR “All Glass” and VZ Spin-Top Types. Also applies for VMER40 and VMEP40 in DE4B models.
2Models suitable for Class II Div. 1 are also suitable for Class III.
* DE3B models use 5-1/2" CertiLite®V VM optics; DE4B models use 7-3/4" VM optics.
CLASS II DIVISION 12
CATALOG SERIES* LAMP AMBIENT GLOBE OR GLOBE + SUPPLY WIRE
WATTS DEG. C REFRACTOR1REFLECTOR TEMP. MIN. °C
VE3B0013 1 X 13 40 T3 T3 T6 T6 T3B (EFG) T3B (EFG) 60
VE3B0026 2 X 13 40 T3 T3 T6 T6 T3B (EFG) T3C (EFG) 60
VE3B1313 1 X 13 40 T3A T3A T6 T6 T3B (EFG) T3C (EFG) 60
VE3B2613 2 X 13 40 T3 T3 T6 T6 T3B (EFG) T3C (EFG) 60
VE3B2626 2 X 13 40 T3 T3 T6 T6 T3B (EFG) T3C (EFG) 60
VE3Q0018 1 X 18 40 T6 T6 T6 T6 T3B (EFG) T3C (EFG) 60
VE3Q0036 2 X 18 40 T3C T3C T6 T6 T3B (EFG) T3C (EFG) 60
VE3Q1818 1 X 18 40 T3A T3A T6 T6 T3B (EFG) T3C (EFG) 60
VE3Q3618 2 X 18 40 T3C T3C T6 T6 T3B (EFG) T3C (EFG) 60
VE3Q3636 2 X 18 40 T3C T3C T6 T6 T3B (EFG) T3C (EFG) 60
VE3Q0026 1 X 26 40 T6 T6C T6 T6 T3B (EFG) T3C (EFG) 75
VE3Q0052 2 X 26 40 T2D T2D T6 T6 T3B (EFG) T3C (EFG) 75
VE3Q2626 1 X 26 40 T3A T3A T6 T6 T3B (EFG) T3C (EFG) 60
VE3Q5226 2 X 26 40 T2D T2D T5 T5 T3B (EFG) T3C (EFG) 75
VE3Q5252 2 X 26 40 T2D T2D T5 T5 T3B (EFG) T3C (EFG) 75
VE3Q0032 1 X 32 40 T6 T6 T6 T6 T3B (EFG) T3C (EFG) 75
VE3Q0064 2 X 32 40 T2D T2D T6 T6 T3B (EFG) T3C (EFG) 75
VE3Q3232 1 X 32 40 T3A T3A T6 T6 T3B (EFG) T3C (EFG) 60
VE3Q6432 2 X 32 40 T2D T2D T5 T5 T3B (EFG) T3C (EFG) 75
VE3Q6464 2 X 32 40 T2D T2D T5 T5 T3B (EFG) T3C (EFG) 75
VE3Q0042 1 X 42 40 T6 T6 T6 T6 T3B (EFG) T3C (EFG) 75
VE3Q0084 2 X 42 40 T2B T2B T6 T6 T3B (EFG) T3C (EFG) 75
VE3Q4242 1 X 42 40 T3A T3A T6 T6 T3B (EFG) T3C (EFG) 60
VE3Q8442 2 X 42 40 T2B T2B T4 T4 T3B (EFG) T3C (EFG) 75
VE3Q8484 2 X 42 40 T2B T2B T4 T4 T3B (EFG) T3C (EFG) 75
VE4B0013 1 X 13 40 T3 T3 T6 T6 T3B (EFG) T3C (EFG) 60
VE4B0026 2 X 13 40 T3 T3 T6 T6 T3B (EFG) T3C (EFG) 60
VE4B1313 1 X 13 40 T3A T3A T6 T6 T3B (EFG) T3C (EFG) 60
VE4B2613 2 X 13 40 T3 T3 T6 T6 T3B (EFG) T3C (EFG) 60
VE4B2626 2 X 13 40 T3 T3 T6 T6 T3B (EFG) T3C (EFG) 60
VE4Q0018 1 X 18 40 T3C T3C T6 T6 T4A (EFG) T4A (EFG) 60
VE4Q0036 2 X 18 40 T3C T3C T6 T6 T4A (EFG) T4A (EFG) 60
VE4Q1818 1 X 18 40 T3C T3C T6 T6 T4A (EFG) T4A (EFG) 60
VE4Q3618 2 X 18 40 T3C T3C T6 T6 T4A (EFG) T4A (EFG) 60
VE4Q3636 2 X 18 40 T3C T3C T6 T6 T4A (EFG) T4A (EFG) 60
VE4Q0026 1 X 26 40 T3C T3C T6 T6 T4A (EFG) T4A (EFG) 60
VE4Q0052 2 X 26 40 T3C T3C T6 T6 T4A (EFG) T4A (EFG) 60
VE4Q2626 1 X 26 40 T3C T3C T6 T6 T4A (EFG) T4A (EFG) 60
VE4Q5226 2 X 26 40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
VE4Q5252 2 X 26 40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
VE4Q0032 1 X 32 40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
VE4Q0064 2 X 32 40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
VE4Q3232 1 X 32 40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
VE4Q6432 2 X 32 40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
VE4Q6464 2 X 32 40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
VE4Q0042 1 X 42 40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
VE4Q0084 2 X 42 40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
VE4Q4242 1 X 42 40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
VE4Q8442 2 X 42 40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
VE4Q8484 2 X 42 40 T3 T3 T6 T6 T4A (EFG) T4A (EFG) 75
D E 3 B | V E 3 B | V E 3 Q
DE4B | VE4B | VE4Q SERIES LIGHTING
COMPONENTS/APPLICATION DATA
L205
L205
L
1T-codes for Refractors include VMR “All Glass” and VZ Spin-Top Types. Also applies for VMER40 and VMEP40 in DE4B models.
2Models suitable for Class II Div. 1 are also suitable for Class III.
* DE3B models use 5-1/2" CertiLite®V VM optics; DE4B models use 7-3/4" VM optics.
APPLICATION DATA
CLASS I DIVISION 2 CLASS I ZONE 2 nR II CLASS II DIVISION 13
CATALOG SERIES* LAMP AMBIENT GLOBE OR GLOBE + GLOBE OR GLOBE + GLOBE OR GLOBE + SUPPLY WIRE
WATTS DEG. C REFRACTOR1REFLECTOR REFRACTOR2REFLECTOR REFRACTOR1REFLECTOR TEMP. MIN. °C
NWP SERIES LIGHTING
NON-METALLIC EMERGENCY OPTION SURFACE MOUNT LUMINAIRES
L
L206
LAMP VOLTAGE DESCRIPTION CAT. NUMBER1MAX.AMBIENT MIN
SUITIBILITY3START
NORMAL POWER MODELS - AMBIENT SUITABILITY 40°C MAX.
1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFN1330A 40°C 15°C
1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFN1830A 40°C 15°C
1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFN2630A 40°C 15°C
1-26W 120V DCK 26W WALL OR CEILING NWPFN26DC120A 40°C 15°C
NORMAL AND EMERGENCY MODELS
1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFE131330A 35°C 15°C
1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFE181830A 30°C 15°C
EMERGENCY ONLY MODELS - AMBIENT SUITABILITY 40°C MAX.
1-13W 120-277V 50/60HZ 13W WALL OR CEILING NWPFEOO1330A 40°C 0°C
1-18W 120-277V 50/60HZ 18W WALL OR CEILING NWPFEOO1830A 40°C 0°C
1-26W 120-277V 50/60HZ 26W WALL OR CEILING NWPFE002630A 40°C 0°C
1-26W 120V DC226W WALL OR CEILING NWPFE0026DC120A 40°C 0°C
L206
FEATURES-SPECIFICATIONS
Class I, Div. 2, Groups A,B,C,D
Class I, Zone 2, Groups IIC, IIB, IIA
Class II, Div. I, Groups F,G
Class III
Marine
NEMA 3, 4, 4X, IP66
Certified - File LR11713
Applications
Killark's NWP Series of fluorescent luminaires
are designed for task lighting of wet & corrosive
NEMA 4X environments and hazardous locations.
Typical uses include manufacturing plants,
chemical and petrochemical processing facili-
ties, sewage treatment plants, off-shore and
dockside installations, agricultural, commercial,
industrial, and mining facilities.
NWP surface mount luminaires contain no
exposed glass and carry Class II, F&G ratings
required for many food proccessing areas.
Features
Non-metallic housing has a lightweight yet
robust low profile construction
Can be wall mounted or ceiling mounted in
horizontal or vertical position
Energy and labor saving fluorescent
Emergency and normal power models available.
Emergency version has internal battery which
provides 90 minutes of illumination in the
event of a power failure
Resists corrosive effects of most chemicals,
hydrocarbons and solvents
Designed for indoor and outdoor applications
Includes fluorescent lamp
'World Voltage' ballasts for 120VAC through
277VAC 50/60Hz installations
Wiring terminals are included as standard
Materials
Enclosure - High strength polycarbonate
Gasket - Silicone
External Hardware - Stainless steel
Lens - Lexan®
Entry - One ¾" NPT copper-free aluminum
hub with ¾ x ½" reducer is standard. A second
hub may be purchased separately.
Lexan®is a registered trademark of General Electric
Ceiling Mounted
Wall Mounted
Exit Sign
Surface Mount Luminaires
13-26W Fluorescent
Catalog Number Logic
NWP WALLPACK 13-26W FLUORESCENT WLONE 3/4" ALUMINUM HUB
1Provlded with one 3/4 aluminum hub as standard.
2NWPFN120V DC model is cCSAus, NWPFE 120V DC emergency-only model is Killark self-certified.
3T-code measurements taken in 40°C ambient; operating ambient reduced for normal and
emergency models to maintain battery performance.
NWP SERIES LIGHTING
NON-METALLIC EMERGENCY OPTION SURFACE MOUNT LUMINAIRES L207
L207
L
Class I
Div. 2
T3
T3
T3
T6
T3
T3
NWP-DECAL06
NWP-DECAL05
EXIT
NWPFN2630x
Candlepower - 26 Watt
CFL26 lamp 1800 lumens
For 13 Watt multiply by .50
For 18 Watt multiply by .67
Zonal Lumen Summary
Zone Lumens %Lamp %Fixt
0-30 275 15.3% 20.3%
0-40 463 25.7% 34.2%
0-60 886 49.2% 65.5%
0-90 1301 72.3% 96.1%
90-120 52 2.9% 3.9%
90-130 52 2.9% 3.9%
90-150 52 2.9% 3.9%
90-180 52 2.9% 3.9%
0-180 1353 75.2% 100
Total Luminaire Efficiency = 75.2%
Space to Mt. Ht. Ratio: End 1.3; Side 1.4
Certified Report BAL 15312.0
NWP-DECAL01
FIELD HUB KITS
Catalog # Description
NWP-HUBA Aluminum hub, gasket, locknut
NWP-HUBP Precoated zinc hub, gasket, locknut
NWP-HUBS Stainless steel hub, gasket, locknut
NWP-HUBM M20 Plated Brass
Keyhole Slots Provided for Ease in Mounting
ACCESSORIES
BOLT ON EXIT SIGN
PHOTOMETRICS
TECHNICAL DATA
NWP-DECAL07
NWP-DECAL02
Optional decal styles available upon request - Minimums apply.
Factory installed decals, order as FAD_ _. Example FAD01.
Use .1 Amp for ‘Emergency Only’ units, or as an adder for
Normal & Emergency models.
1Normal power or normal + emergency
2Emergency only models
3See catalog grids for ambient suitability
NWP-DECAL08
NWP-DECAL03
NWP-DECAL09
NWP-DECAL04
NWP-DECAL10 NWP-DECAL11 NWP-DECAL12
EXITEXITEXIT
SALIDA
EXIT
SALIDA SALIDA
SELF ADHESIVE DECALS
T-Codes @ 40c 3
1 2
WATTS
13W
18W
26W
Class II Minimum
Div. 2 Start
C0F0
F,G -15 4
F,G -15 4
F,G -15 4
Fluorescent Operating Max. Amps
120VAC
.144
.158
.22
TYPE
13W Fluorescent
18W Fluorescent
26W Fluorescent
277VAC
.067
.073
.097
0.26 TYP 4 PLACES
7.09
1.20
0.39
2.59 5.75
11.16
7.13
4.47
1.43
Catalog Number NWP-EXIT-SIGN
DESCRIPTION
Bolt-on Exit Sign accessory includes hardware
to mount to fixture and ability to make arrows
left, right or none. Construction white painted
steel and nonglass red diffuser, with bottom
opening for downlight.
7.87
DBFE SERIES LIGHTING
LINEAR FLUORESCENT EMERGENCY LIGHTING
L208
FEATURES-SPECIFICATIONS
Class I, Div. 2, Groups A,B,C,D
Class I, Zone 2, Groups IIC, IIB, IIA
Class ll, Div. 2 Groups F,G
NEMA 3, 4
UL Listed
Compliances: UL 44; UL 81570, UL924
UL Wet Location Listed (Indoor & Outdoor)
Applications
LINEARLITE DBFE Emergency Lighting
fixtures provide continuous illumination
under normal power and switch to
emergency battery backup during
power outages. Units contain
a battery unit that provides the OSHA
required 90 minutes of illumination for
egress.
Units are designed for general and task
lighting in areas where flammable
gases or vapors or combustible dusts
may exist due to abnormal conditions,
and create a Division 2 hazardous
location, as defined by the NEC.
Features
Sheet steel 20 ga. housing with con-
tinuous weld prevents foreign matter
from entering enclosure
Lens frame assembly has silicon rub-
ber gasketing and heat tempered
glass lens
Electrostatically applied polyester
finish
NEMA 4 construction for wet locations
LED charging indicator light visible
through lens
Push-To-Test Button mounted on
sloping side of fixture - allows
end-to-end mounting of fixtures
EMERGENCY LUMEN CHART
LAMPS INITIAL AFTER
LUMENS 90 MINUTES
2 32W Lamps 625 455
2 40W Lamps 610 420
1 60W Lamp 780 460
Notes: Emergency unit will start lamps at 0ºF
32W T8 Electronic ballast minimum start is 0ºF;
40W ballast is electronic with 50ºF start (add CW for electromagnetic 0ºF);
60W electromagnetic ballast start -20ºF
32W & 40W units operate 2 Lamps in emergency mode for maximum illumination
60W units operate a single lamp. 3 Lamp 60W emergency units not available.
For dimensional data and mounting accessories, see DBF series page L172.
Digit after E is number of lamps energized during power loss.
CATALOG CONDUIT NUMBER LINE DESCRIPTION
NUMBER SIZE OF LAMPS VOLTAGE
DBFE232302 120-277V 50/60 Hz 32W T8 electronic ballast OºF start
Medium bi-pin base
DBFE24012 3/4" 120V 60 Hz 40W T12 bi-pin 50ºF start electronic
DBFE24042 2277V 60 Hz Medium bi-pin base
DBFE16012 120V 60 Hz 60W rapid start high output F48T12/HO
DBFE16042 277V 60 Hz Recessed double contact 800MA
DBFE232303 120-277V 50/60 Hz 32W T8 electronic ballast OºF start
3/4" 3 Medium bi-pin base
DBFE24013 120V 60 Hz 40W T12 bi-pin 50ºF start electronic
DBFE24043 277V 60 Hz Medium bi-pin base
KFBP7 (32/40 or 60 Watt) Replacement battery unit
DBFE FLUORESCENT EMERGENCY LIGHTING
DBFE HAZARDOUS LOCATION APPLICATION DATA
NO.
OF
LAMPS
LAMP
WATTS
RATED
AMBIENT
°C
NEMA
TYPE 3
(RAINTIGHT)
NEMA
TYPE 4
(HOSEDOWN)
SUPPLY WIRE
SUITABLE
FOR °C MIN.
CLASS I, DIV. 2,
GROUPS A,B,C,D
MAX. LAMP TEMP.°C
UL/CSA TEMP./I.D.
CLASS II, DIV. 2,
GROUPS E.F,G
MAX. SURF. TEMP.°C
UL/CSA TEMP./I.D.
2
3
2
32/40
32/40
60
YES
YES
YES
YES
YES
YES
40
40
40
90
90
90
T6 (85°C/185°F)
T5 (100°C/212°F)
T4A (120°C/248°F)
T6 (85°C/185°F)
T6 (85°C/185°F)
T6 (85°C/185°F)
5KFBP7 6KFBP7H
O
LZ2NE/LZ2NSE SERIES EMERGENCY FLUORESCENT L209
FEATURES-SPECIFICATIONS
L
EMERGENCY LUMEN CHART
Certified - File LR11713
Class I, Div. 2 Groups A,B,C,D
Class l, Zones 2, Groups IIC,llB,llA
Class II, Div. 1 & 2, Groups E3, F,G
AEx nAII, Ex nAII
Wet Locations
NEMA 4X, IP66
LZ2SE 4’ Stainless
LZ2NE 2’ Non-metallic
Type Approval
ABS
Food Handling4
NSF
1Digit after E is number of lamps energized during
power loss. For optional fused ballasts, add to catalog
number F1 for 120V, F4 for 277V, F8 for 230V. Fusing no
for marine or Canadian use. Lamps not included.
2Magnetic ballast
LAMPS
2 X 1 7 T 8
1 X 40 BIAXIAL
1 X 55 BIAXIAL
1 X 2 8 T 5
1 X 3 2 T 8 ( E 1 )
2 X 3 2 T 8 ( E 2 )
2 X 4 0 T 1 2
1 X 4 4 T 8
1 X 5 4 T 5
1 X 6 0 T 1 2
INITIAL LUMENS
550
900
950
1175
925
625
610
950
1200
780
Applications
LINEARLITE Emergency Lighting
fixtures provide continuous illumi-
nation under normal power and
switch to emergency battery back-
up during power outages. Units
contain a battery unit that provides
the OSHA required 90 minutes of
illumination for egress.
Units are available in non-metallic
or 316 Stainless construction and
designed for wet, harsh and corro-
sive environments. The LZ2NE and
LZ2SE Series can also be used in
Class I, Division 2 and Zone 2 haz-
ardous vapors and in Class II areas
where combustible dusts may
exist. Typical areas used are in
refineries, chemical plants, waste
water & sewage treatment facilities,
as well as in tunnels, food process-
ing and coastal areas.
ABS (American Bureau of
Shipping) type approval for use on
decks, vessels, platforms, garages,
ships and boats. Also suitable for
docks and marinas.
3LZ2SE only for Group E
4LZ2NE is NSF approved
Additional Data
L173 or L174 - Features
L175 - Ballast Data
L176 - Mounting Accessories
L176 - L177 - Photometrics
Features
NEMA 4 & IP66 rated enclosure
Housing-one piece fiberglass reinforced poly-
ester or 316 Stainless Steel
Clear Lexan®impact resistant polycarbonate
lens (Lexan is a registered trademark of
General Electric)
Two 3/4" NTP hubs - one at each end
(includes one 3/4" close-up plug and two 3/4"
X 1/2" reducers for maximum user flexibility
Two 1/4"- 20 bushings furnished in top of fix-
ture for threaded rod
LZ2NE/LZ2SE BATTERY-BACKED
NUMBER OF
LAMPS/WATTS
1-40W6
1-55W6
2-40W6
4-40W6
2-17W5
3-17W5
2-28W6
3-28W6
2-32W6
2-32W5
3-32W6
3-32W5
2-40W5
2-44W6
2-54W6
2-60W5
BIAXIAL LAMP TYPE FIXTURES
VOLTAGE
A C 6 0 H z
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
120-277V
347V
120-277V
120-277V
347V
120V
277V
230V 50 Hz2
120-277V
120-277V
120-277V
DOUBLE-ENDED LAMP TYPE FIXTURES
DESCRIPTION
2' 1-Lamp Biaxial Electronic 50/60 Hz
0°F Start 4-Pin
2' 1-Lamp Biaxial Electronic 50/60 Hz
0°F Start 4-Pin
2' 2-Lamp Biaxial Electronic 50/60 Hz
0°F Start 4-Pin
4' 4-Lamp Biaxial Electronic 50/60 Hz
0°F Start 4-Pin
2' 2-Lamp T-8 Electronic 50/60 Hz
0°F Start Medium Bi-Pin
2' 3-Lamp T-8 Electronic 50/60 Hz
0°F Start Medium Bi-Pin
4' 2-Lamp T-5 Electronic 50/60 Hz
0°F Start Miniature Bi-Pin
4' 3-Lamp T-8 Electronic 50/60 Hz
0°F Start Miniature Bi-Pin
4' 2-Lamp T-8 Electronic 50/60 Hz
0°F Start Medium Bi-Pin
4' 3-Lamp T-8 Electronic 50/60 Hz
0°F Start Medium Bi-Pin
4' 2-Lamp T-12 Electronic Medium Bi-Pin
Start 50°F 40W/60°F 34W
4' 2-Lamp T-8 Electronic -20°F Start
High Output Recessed Double Contact
4' 2-Lamp T-5 Electronic 50/60 Hz
-20°F Start Miniature Bi-Pin
4' 2-Lamp T-12 Electronic -20°F Start
High Output Recessed Double Contact
LZ2NE1
LZ2NE1-40130
LZ2NE1-55130
LZ2NE1-40230
LZ2NE1-40430
LZ2NE2-17230
LZ2NE2-17330
LZ2NE1-28230
LZ2NE1-28330
LZ2NE1-32230
LZ2NE2-32230
LZ2NE2-32215
LZ2NE1-32330
LZ2NE2-32330
LZ2NE2-32315
LZ2NE2-40201
LZ2NE2-40204
LZ2NE2-40208
LZ2NE1-44230
LZ2NE1-54230
LZ2NE1-60201
LZ2SE1
LZ2SE1-40130
LZ2SE1-55130
LZ2SE1-40230
LZ2SE1-40430
LZ2SE2-17230
LZ2SE2-17330
LZ2SE1-28230
LZ2SE1-28330
LZ2SE1-32230
LZ2SE2-32230
LZ2SE2-32215
LZ2SE1-32330
LZ2SE2-32330
LZ2SE2-32315
LZ2SE2-40201
LZ2SE2-40204
LZ2SE2-40208
LZ2SE1-44230
LZ2SE1-54230
LZ2SE1-60230
REPLACEMENT BATTERY UNIT
HFXE SERIES LIGHTING
LINEAR FLUORESCENT EMERGENCY LIGHTING
L210
FEATURES-SPECIFICATIONS
Listed - File E12976 and E89665 (Marine)3
UL 924, UL 844
Certified - File LR11713
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
NEMA 3, 7(C,D) 9(E,F,G)
Suitable for wet locations
2’ Nominal
Style
4’ Nominal
Style
Applications
HFXE Series Emergency Lighting fix-
tures provide continuous illumination
under normal power and switch to
emergency battery backup during
power outages. Units contain
a battery unit that provides the OSHA
required 90 minutes of illumination for
egress.
Units are designed for installations
where moisture, dirt, dust, corrosion
and vibration may be present, or wet
locations where wind, water and snow
can be expected. They can also be
used in locations made hazardous due
to the presence of flammable or explo-
sive gases, vapors and combustible
ducts as defined by the NEC.
Features
Construction is strong lightweight
corrosion resistant copper-free alu-
minum alloy, less than 4/10 of 1%
All external hardware is corrosion
resistant 316 stainless steel to pro-
vide maintenance free long life
World voltage ballasts standard on
32W and BIAXIAL models (120-277V
50/60 Hz)
LED charging indicator light on bal-
last enclosure.
CONDUIT LINE VOLTAGE DESCRIPTION PROFILE
SIZE
HFXE2-265-302 120-277V 50/60 Hz 32W T8 electronic ballast 265MA
HFXE2-430-12 120V 60 Hz 40W T12 electronic ballast 430MA
HFXE2-430-42 3/4" 277V 60 Hz 40W T12 electronic ballast 430MA
HFXE1-800-12 120V 60 Hz 60W T12 electronic ballast 800MA
HFXE1-800-42 277V 60 Hz 60W T12 electronic ballast 800MA
HFXE2-265-303 120-277V 50/60 Hz 32W T8 electronic ballast 265MA
HFXE2-430-13 120V 60 Hz 40W T12 electronic ballast 430MA
HFXE2-430-43 3/4" 277V 60 Hz 40W T12 electronic ballast 430MA
HFXE1-800-13 120V 60 Hz 60W T12 electronic ballast 800MA
HFXE2-265-304 120-277V 50/60 Hz 32W T8 electronic ballast 265MA
HFXE2-430-14 120V 60 Hz 40W T12 electronic ballast 430MA
HFXE2-430-44 277V 60 Hz 40W T12 electronic ballast 430MA
HFXE1-800-14
3/4"
120V 60 Hz 60W T12 electronic ballast 800MA
HFXE1-800-44 277V 60 Hz 60W T12 electronic ballast 800MA
BIAXIAL SERIES
HFXE1-40T-302 2’ 2 Lamp 40W BIAXIAL
HFXE1-55T-302 2’ 2 Lamp 55W BIAXIAL
HFXE1-40T-304 3/4" 120-277V 50/60 HZ 4’ 4 Lamp 40W BIAXIAL
HFXE1-55T-304 4’ 4 Lamp 55W BIAXIAL
HFXE FLUORESCENT EMERGENCY LIGHTING
Two Glass Tubes
4’ Nominal
Three Glass Tubes
4’ Nominal
1Digit after “E” in catalog logic indicates number of lamps energized in emergency mode.
2Consult non-emergency HFX pages L164-169 for thermal, dimensional and other data, plus for avail-
able accessories. 40W & 60W are not available with universal voltage or 240V 50Hz ballasts.
31,2 and 3 tube models are third party certified. 4 tube models are self-certified.
NOTES: For fusing, add suffix F1 for 120V; F4 for 277V.
Emergency unit will start lamps at 0°F
32W T8 electronic ballast minimum start is 0°F
40W ballast is electronic with 50°F start (add CW for electromagnetic 0°F)
60W elecromagnetic ballast start at -20°F
32W & 40W units operate 2 lamps in emergency mode for a maximum illumination
60W and BIAXIAL units operate a single lamp. 3 lamp 277V 60W emergency units not available.
Replacement Battery Pack #KFBP10
Four Glass Tubes
4’ Nominal
CATALOG
NUMBER1 2
Two Glass Tubes
4’ Nominal
EMERGENCY LUMEN CHART
LAMPS INITIAL LUMENS AFTER 90 MINUTES
2 32W lamps 1350 900
2 40W lamps 1100 640
1 60W lamp 1200 810
1 40W BIAXIAL 900 540
1 55W BIAXIAL 900 465
SEE PAGES L180 TO L185 FOR DIMENSIONS,
ACCESSORIES AND PHOTOMETRICS
3
EEQ SERIES LIGHTING
COMPACT FLUORESCENT EMERGENCY LIGHTING L211
FEATURES-SPECIFICATIONS
L
See Page L212 for available Push-
To-Test hazardous location control
stations.
Features
Quad-Pin long-life triple-tube com-
pact fluorescent lamps included
Choice of Pendant, Ceiling, Wall or
Stanchion mount
Factory Sealed - No external seal
required
Corrosion resistant-Copper-free
aluminum (less than 4/10 of 1%)
die-cast construction w/Baked-on
epoxy/polyester powder finish
Exposed hardware is 316 grade
stainless steel
LED charging indicator light visible
through lens
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3
Compliances: UL 844; UL 1570, UL924 (File E162407)
UL Wet Location Listed (Indoor & Outdoor)
Rated for 40Cº ambient. Minimum start 0º C
Temperature codes:
Class I C,D T6;
Class II E,F,G T4;
Suitable for Class III
Certified File LR11713
EEQ 26, 32 & 42WATT NORMAL & EMERGENCY MODE FIXTURES
QUAD-PIN FLUOR. LINE VOLTAGE CATALOG NUMBER 346
LAMP INCLUDED @ 60 HZ PENDANT 3/4" 1CEILING 3/4" 1BRACKET 3/4" 1STANCHION 1-1/4" 2
26Watt 120 or 277VAC5EEQ2626E10A2GG EEQ2626E10X2GG EEQ2626E10B2GG EEQ2626E10D4GG
32Watt 120 or 277VAC5EEQ3232E10A2GG EEQ3232E10X2GG EEQ3232E10B2GG EEQ3232E10D4GG
42Watt 120 or 277VAC5EEQ4242E10A2GG EEQ4242E10X2GG EEQ4242E10B2GG EEQ4242E10D4GG
Applications
HOSTILELITE®EEQ Emergency
Lighting fixtures provide continuous illu-
mination under normal power and
switch to emergency battery backup
during power outages. Emergency
Units ONLY are available that operate
only when normal power fails.
Units contain battery unit that provides
the OSHA required 90 minutes of illumi-
nation (same lamp) for egress.
Units are designed for general and task
lighting indoors or outdoors where flam-
mable gases or vapors or combustible
dusts exist and create a hazardous
location, as defined by the NEC.
Accessories
Exit sign: Model HEXA-100 (note omit
2nd “G” in catalog number for globe-only
fixture) see page L144.
Reflectors: Use standard dome ERSD15
or angle model ERA15 (see page L146).
EEQ 26, 32 & 42WATT EMERGENCY-ONLY MODE FIXTURES
QUAD-PIN FLUOR. LINE VOLTAGE CATALOG NUMBER 346
LAMP INCLUDED @ 60 HZ PENDANT 3/4" 1CEILING 3/4" 1BRACKET 3/4" 1STANCHION 1-1/4" 2
26Watt 120 or 277VAC5EEQ0026E10A2GG EEQ0026E10X2GG EEQ0026E10B2GG EEQ0026E10D4GG
32Watt 120 or 277VAC5EEQ0032E10A2GG EEQ0032E10X2GG EEQ0032E10B2GG EEQ0032E10D4GG
42Watt 120 or 277VAC5EEQ0042E10A2GG EEQ0042E10X2GG EEQ0042E10B2GG EEQ0042E10D4GG
LUMEN OUTPUT7
LAMP SOURCE NORMAL POWER EMERG. POWER
26Watt 1800 450
32Watt 2400 575
42Watt 3200 750
BALLAST DATA
LAMP WATTS VOLTAGE OPERATING AMPS INPUT WATTS BALLAST CIRCUIT REGULATION
26Watt (1x26) 120 / 277 VAC .24@120V /.11 @277V 29 HPF Electronic
32Watt (1X32) 120 / 277 VAC .31@120V /.13 @277V 36 HPF Electronic
42Watt (1x42) 122 / 277 VAC .38@120V /.17 @277V 46 HPF Electronic
1Pendant, Ceiling & Bracket models may be
changed to 1" hubs by changing the 12th character
from 2to 3; e.g. EEQ2626E10A3GG.
2Stanchion fixtures are 1-1/2" with a 1-1/2 to 1-1/4"
reducer.
3Omit 2nd “G” for globe-only fixture for use with
HEXA-100 Exit Accessory.
4Standard color for fixtures is Killark beige. Add -R
for RED adder..
5All EEQ fixtures are factory set to 120V and can be
changed to 277V in field by following included
instructions. Replacement battery pack kit KFBP9.
6EEQ fixtures use a tank extension ring and are 2-
1/2" taller than EBF fixtures (see page L143).
7Photometric characteristics similar to EBF26 page
L152, except adjusted for lumen output.
EBB SERIES LIGHTING
HALOGEN LAMP EMERGENCY LIGHTING
L212
FEATURES-SPECIFICATIONS
Remote test station (included) allows “Push-To-
Test” at a location convenient to the user. 2
Applications
Where required by NEC, Life Safety
Code, etc., to provide illumination dur-
ing interruption of normal power to
lighting system.
Hazardous Locations (gas, vapor,
dust), include such areas as: Oil & Gas
Refining, Production & Storage, Grain
Processing, Paint Manufacture.
Features
Patented design three high intensity
lamps can be independently adjust-
ed to provide custom emergency
lighting to a specific area
Three 20 watt MR16 lamps included
Pendant, bracket and ceiling mount-
ing styles for a mounting arrange-
ment that suits any lighting layout
Remote hazardous location test sta-
tion (included) allows testing of fixture
at a convenient ground level location
Factory wired for 120V; can be field
changed to 208/240/277V.
Four tough, long life lead-acid batter-
ies require no maintenance and have
a 12 VDC output of 60 watts for 90
minutes
Safety disconnect feature automati-
cally disconnects lamps from battery
if globe is removed
Solid state battery charger has a low
voltage disconnect feature
Red pilot light, easily visible inside
globe, indicates AC power is being
supplied to batter charger
Fixture housings are factory sealed
by the electro-mechanical connection
block
The only wiring required is attaching
supply wires to the integral female
connection block in the mounting
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class ll, Div. 1 & 2 Groups E,F,G
Class lll, Div. 1 & 2
NEMA 7CD, 9EFG
Listed File E162407
UL-844 Electric Lighting Fixtures for use in
Hazardous Locations
UL-924 Emergency Lighting & Power Equipment
Certified File LR11713
cap. Threading fixture onto mounting
cap makes the electrical connection
Electrical continuity is not made dur-
ing assembly or disassembly without
five or more threads secured to
insure a flame path
Suitable in ambients 0°C to 40°C
1Suitable for 220V/50Hz.
HAZARDOUS LOCATION APPLICATION DATA
LAMP TYPE LAMP WATTS RATED AMBIENT DEGREES MAX SURFACE TEMPERATURE
CLASS I CLASS II SIMULTANEOUS CLASS I & II
MR16 Halogen 60W Total 40°C T6 (85°C) T5 (100°C) T5 (100°C)
ANSI LAMP TYPE WATTS VOLTAGE1HUB SIZE PENDANT WALL CEILING
MR16 3x20W 120, 208, 240, 277V 3/4" EBB32010A2 EBB32010B2
EBB32010A3 EBB32010B3 EBB32010X3
EBB ACCESSORIES
CATALOG NUMBER DESCRIPTION
EZG1
VMPSD40
EBB-L12
17505AAAB
EBB-RB
EBB-BC
EBB-TRANS*
EBB-PL
Guard (die cast aluminum)
Reflector (standard dome)
MR16 12 volt lamp
MR16 lamp socket
Rechargeable battery (4 used per unit)
Battery charger (circuit board)
Transformer Kit 120, 208, 240, 277V
LED pilot light
EBB HALOGEN EMERGENCY LIGHTING
CATALOG NUMBER
1"
Note: EBB Series fixtures should not be stored for extended periods before energizing.
2Furnished with 3/4" feed thru mounting box. For Push-To-Test N.C. momentary cover only. Use also
with HFXE, DE3B, VE3Q, EEQ, and LZ2NE. Cover only XCS-0B2-PTT. Order SWB back box separately.
* Replaces #17506AAAB.
EBB SERIES LIGHTING
HALOGEN LAMP EMERGENCY LIGHTING L213
FEATURES-SPECIFICATIONS
L
Photometrics
Typical vertical
ISO foot candle
distribution.
One 20 watt lamp
aimed at 20° below
horizontal.
Note: Some minor vari-
ations in light spread
will occur as each
lamp is rotated
up/down within the
glass globe.
Pendant Ceiling Wall Mount
Lamps adjustable on 2 axis for
maximum aiming flexibility.
Factory sealed; external seals not
required
Cast of copper-free Aluminum
(Less than 0.4% copper)
Electrostatically applied epoxy polyester
finish is baked on for high density
corrosion protection
Four lead-acid batteries are mainte-
nance free and provide 60 watts to the
lamps for 90 minutes*
Red pilot light indicates AC power flow
to battery charger
Lamps automatically disconnect from
battery if globe is disengaged
Glass globe prestressed for heat and
impact resistance - Globe is internally
fluted on sides and prismatic on bottom
* EBB Series fixtures should not be
stored for extended periods before
energizing.
Wireless assembly of fixture tank to
mounting cap — Electro-mechani-
cal male/female block allows fast,
easy installation and bench top ser-
vicing without disconnecting supply
wires
Nameplate displays Third Party
Certifications and ratings in English
and French (large red plate identi-
fies it as an emergency fixture)
Acme double lead threads assure
quick and trouble free assembly
Class I, Div. 1 & 2, Groups C,D
Class I, Zones 1 & 2, Groups IIB, IIA
Class ll, Div. 1 & 2 Groups E,F,G
Class lll, Div. 1 & 2
NEMA 7CD, 9EFG
Listed File E162407
UL-844 Electric Lighting Fixtures for use in
Hazardous Locations
UL-924 Emergency Lighting & Power Equipment
Certified File LR11713
Dimensions: See EZ 50-250 Watt dimensions on page L147
VEXA400 Exit Accessory
White painted steel frame
8" Red Letters
5 Panes: 3 Exit and 2 Blank
Fits EBB and VE4Q with
globe only
Dimensions: 14.57" x 9.22"
ESX SERIES LIGHTING
STROBE SIGNAL LIGHT
L214
FEATURES-SPECIFICATIONS
Listed - File E84609
Certified - File LR11713
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
Suitable for wet locations
UL Marine
NEMA 3, 4X
Factory sealed
ES X 0 0000 00 0 (CEN)*
Catalog Number Logic
Series Constant
Signal Type
X—Strobe
Lens Color
A—Amber
B—Blue
C—Clear
G—Green
R—Red
Voltage
120A—120 VAC 50/60 Hz.
240A—240 VAC 50/60 Hz.
1274—12 through 74 VDC
Mounting Style
A2—3/4" Pendant
A3—1" Pendant
X2—3/4" Ceiling
X3—1" Ceiling
B2—3/4" Bracket
B3—1" Bracket
D4—1-1/4"/1-1/2"
Stanchion
Guard
G—Guard
Add letter “G
to end of catalog
number if guard
is required.
CATALOG NUMBER VOLTAGE
ESX120PS 120VAC, 50/60 HZ.
ESX240PS 220/240VAC, 50/60 HZ.
ESX1274PS 12-74 VDC
REPLACEMENT POWER SUPPLY
CATALOG NUMBER DESCRIPTION
ESXAL Amber
ESXBL Blue
ESXCL Clear
ESXGL Green
ESXRL Red
EMGS2 Rep globe support assembly
REPLACEMENT LENS & LAMP ASSEMBLY
Applications
HOSTILELITE®ESX Series strobe fixtures
can be an excellent warning device in
hazardous, hostile or wet locations
where hearing is impaired due to high
ambient noise conditions.
Compliances
UL-1203 explosion-proof and dust igni-
tion-proof electrical equipment for use
in hazardous (classified) locations
UL-1638 visual signaling appliances
UL Marine-type electric lighting fixtures
NEMA 3, 4, 4X, 7CD, 9EFG
Specifications
Electronic component temperature
range –40˚C to +55˚C
NEC temperature code, T6 (<85°C)
Flash rate–85 flashes per minute
Xenon type lamp
*CEN (CENELEC) approved option available. See pages L144 for more information. ESX Series
strobes with CENELEC labeling are rated T6 by PTB.
Voltage and amperage:
12-74 VDC:
Draws 1.25A avg. @ 12 VDC
tapering to 0.2A avg. @ 74 VDC,
.75A avg. @ 24 VDC
120 VAC (50/60 HZ):
Draws 0.30A avg.
240 VAC (50/60 HZ):
Draws 0.17A avg.
Power supply output:
13 watts standard
11 watts for 12-74 VDC
Intensity:
Clear 200 candela effective
Amber 170 candela effective
Blue 90 candela effective
Red 40 candela effective
Green 70 candela effective
ESX SERIES LIGHTING
STROBE SIGNAL LIGHT L215
FEATURES-SPECIFICATIONS
L
Listed - File E84609
Certified - File LR11713
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB, llA
Class II, Div. 1 & 2, Groups E,F,G
Class III, Div. 1 & 2
Suitable for wet locations
Marine
NEMA 3, 4X
Factory sealed
1Catalog numbers do not include guards. To order add letter “G to end of catalog number
or order EMG2 separately.
2Catalog numbers include Red lens. To specify different colored lens, change fourth character in
catalog number to one of the following: “B”=Blue, “C”=Clear, “A”=Amber, “G”=Green.
3Standard hub size is 3⁄4" NPT. To order 1" NPT, change last character of catalog number from “2” to “3”.
4Stanchion mount is standard with 1-1⁄2" NPT and a 1-1⁄2" NPT to 1-1⁄4" NPT reducer installed.
NOTE: See EM series for dimensions, page L143.
120 VAC, 50/60 HZ. ESXR120AA2
STROBE 3/4" 240 VAC, 50/60 HZ. ESXR240AA2
12-74 VDC ESXR1274A2
PENDANT ESX STROBE SIGNAL LIGHT1 2
LAMP HUB SIZE3VOLTAGE @60 HERTZ CATALOG NUMBER
TYPE GLOBE AND MOUNT1
CEILING
STANCHION
WALL
PENDANT
120 VAC, 50/60 HZ. ESXR120AX2
STROBE 3/4" 240 VAC, 50/60 HZ. ESXR240AX2
12-74 VDC ESXR1274X2
CEILING ESX STROBE SIGNAL LIGHT1 2
LAMP HUB SIZE3VOLTAGE @60 HERTZ CATALOG NUMBER
TYPE GLOBE AND MOUNT1
120 VAC, 50/60 HZ. ESXR120AB2
STROBE 3/4" 240 VAC, 50/60 HZ. ESXR240AB2
12-74 VDC ESXR1274B2
WALL ESX STROBE SIGNAL LIGHT1 2
LAMP HUB SIZE3VOLTAGE @60 HERTZ CATALOG NUMBER
TYPE GLOBE AND MOUNT1
120 VAC, 50/60 HZ. ESXR120AD4
STROBE 1-1/4" 240 VAC, 50/60 HZ. ESXR240AD4
12-74 VDC ESXR1274D4
STANCHION ESX STROBE SIGNAL LIGHT1 2
LAMP HUB SIZE4VOLTAGE @60 HERTZ CATALOG NUMBER
TYPE GLOBE AND MOUNT1
NVS SERIES LIGHTING
NON-METALLIC CORROSION RESISTANT SIGNALS
L216
4.3/7.4* 11.3
5.9/10.1* 15.4
4.5/7.8* 11.8
2.5/4.3* 6.6
4.8/8.2* 12.5
40 -
10 -
20 -
20 -
50 -
FEATURES-SPECIFICATIONS
Applications
These new signal luminaires can be
excellent warning devices in corrosive,
wet NEMA 4X harsh environments, and
in hazardous locations.
NVS signals contain no exposed glass
and carry Class II, F&G ratings required
for many food processing areas.
Features
NVSL Series LED with very compact
profile and 50,000 hours expected life;
steady - on or flashing.
NVSZ Series Xenon with 10,000 hours
expected life; flashing only.
LED utilizes inverted cone design to
provide full 360 degree coverage for
more light projection.
LED and Xenon available in five colors
colors - red, green, amber, blue
and clear.
Flash rate for LED is 7 micro flashes
approximately every second for
increased visual perception.
Xenon flash rate 60 to 80 per minute
Can be mounted in any orientation in-
cluding lens in the UP or SIDE positions.
Materials: High strength 30% glass-filled
thermoset polyester body with
Lexan®* lens.
Resists corrosive effects of most
chemicals, hydrocarbons and solvents
Designed for indoor and outdoor
applications
Class l, Div. 2, Groups A,B,C,D
Class l, Zone 2, Groups IIC, IIB, IIA
Class Il, Div. 1&2, Group F,G;
Class III
CSA Enclosure Type 4X, IP66
NEMA 4X, Marine Rated
to the following standards:
• UL 1598 Standard for luminaires
• UL 1598A Marine type luminaires
• UL 844 Standard for lighting fixtures for
hazardous locations
• UL 1638 Standard for visual signalling applications
• CSA C22.2 no. 137-M1981 electric luminaires for
use in hazardous locations
• Enclosed and gasketed, NEMA 3, 4X IP66
* Lexan®is a registered trademark of General Electric.
Certified - File LR11713
Catalog Numeric Logic
NVS L C F G 01 A A G
1 2345 6 789
1 NVS - Series Constant
Non-Metallic Signal
2 Source
L = LED
Z = Xenon
3 Fixture Size
C = Compact LED
M = Medium Xenon
4 Flash State
F = Flashing LED or Xenon
S = Steady LED
5 Color (Body, Mount, Guard)
G = Gray
6 Voltage
01 - 120VAC 50/60Hz Xenon model
08 - 240VAC 50/60Hz Xenon model
25 - 120-240VAC 50/60Hz LED model
26 - 12-80VDC (24VAC) LED or Xenon
7 Color of Strobe
A = Amber, R = Red, G = Green, B = Blue,
C = Clear
8 Mount Type
A = 3/4" pendant
X = 3/4" Ceiling
B = 3/4" Wall Bracket (consists of ceiling
box and elbow to support body)
M = M20 Ceiling
W = M20 Wall Mount
9 Guard
G = Guard
N = No Guard
Example: NVSLCFG25AAG
LED Gray Body Flashing Amber
Pendant w/Guard 120-240VAC
PENDANT LED CEILING LED WALL XENON
CL1 CL2
Div.2 Div.1
Operating Groups
Temp. Code
T6 F,G
T2C F,G
HAZARDOUS LOCATION SUITABILITY
Source Series
LED NVSLC
Xenon NVSZM
Ambient
Range
Intensity in Candellas Flashing Steady
Amber
Red
Green
Blue
Clear
Amber
Red
Green
Blue
Clear
LED
Xenon
040mA Flash
020mA Flash
400mA
60mA
198mA Flash
.04 Avg.
.02 Avg.
.40 Avg.
.05 Avg.
.35 Avg.
Electrical Ratings Max.
120VAC
240VAC
12VDC
80VDC
24VAC
120VAC
240VAC
12VDC
80VDC
24VAC
LED
Xenon
Signal Luminaires
-40oC to +40oC
-40oC to +40oC
*CD-S/CD-Effective
LED
TECHNOLOGY
NVS SERIES LIGHTING
NON-METALLIC CORROSION RESISTANT SIGNALS L217
FEATURES-SPECIFICATIONS
L
LED
Down & side orientation Up & side orientation
3/4" Pendant Amber Red Green Blue Clear
NVS SERIES DESCRIPTION/CATALOG ORDERING INFORMATION
Class l, Div. 2, Groups A,B,C,D
Class l, Zone 2, Groups IIC, IIB, IIA
Class Il, Div. 1&2, Group F,G;
Class III
CSA Enclosure Type 4X, IP66
NEMA 4X, Marine Rated
Certified - File LR11713
XENON
LED
XENON
LED
XENON
NVSLCFG25AAG
NVSLCFG26AAG
NVSLCSG25AAG
NVSLCSG26AAG
NVSZMFG01AAG
NVSZMFG26AAG
NVSZMFG08AAG
NVSLCFG25AXG
NVSLCFG26AXG
NVSLCSG25AXG
NVSLCSG26AXG
NVSZMFG01AXG
NVSZMFG26AXG
NVSZMFG08AXG
NVSLCFG25ABG
NVSLCFG26ABG
NVSLCSG25ABG
NVSLCSG26ABG
NVSZMFG01ABG
NVSZMFG26ABG
NVSZMFG08ABG
Flashing 120-240VAC
Flashing 12-80VDC; 24VAC
Steady 120-240VAC
Steady 12-80VDC; 24VAC
Flashing 120VAC
Flashing 12-80VDC; 24VAC
Flashing 240VAC
Flashing 120-240VAC
Flashing 12-80VDC; 24VAC
Steady 120-240VAC
Steady 12-80VDC; 24VAC
Flashing 120VAC
Flashing 12-80VDC; 24VAC
Flashing 240VAC
Flashing 120-240VAC
Flashing 12-80VDC; 24VAC
Steady 120-240VAC
Steady 12-80VDC; 24VAC
Flashing 120VAC
Flashing 12-80VDC; 24VAC
Flashing 240VAC
NVSLCFG25RAG
NVSLCFG26RAG
NVSLCSG25RAG
NVSLCSG26RAG
NVSZMFG01RAG
NVSZMFG26RAG
NVSZMFG08RAG
NVSLCFG25RXG
NVSLCFG26RXG
NVSLCSG25RXG
NVSLCSG26RXG
NVSZMFG01RXG
NVSZMFG26RXG
NVSZMFG08RXG
NVSLCFG25RBG
NVSLCFG26RBG
NVSLCSG25RBG
NVSLCSG26RBG
NVSZMFG01RBG
NVSZMFG26RBG
NVSZMFG08RBG
NVSLCFG25GAG
NVSLCFG26GAG
NVSLCSG25GAG
NVSLCSG26GAG
NVSZMFG01GAG
NVSZMFG26GAG
NVSZMFG08GAG
NVSLCFG25GXG
NVSLCFG26GXG
NVSLCSG25GXG
NVSLCSG26GXG
NVSZMFG01GXG
NVSZMFG26GXG
NVSZMFG08GXG
NVSLCFG25GBG
NVSLCFG26GBG
NVSLCSG25GBG
NVSLCSG26GBG
NVSZMFG01GBG
NVSZMFG26GBG
NVSZMFG08GBG
NVSLCFG25BAG
NVSLCFG26BAG
NVSLCSG25BAG
NVSLCSG26BAG
NVSZMFG01BAG
NVSZMFG26BAG
NVSZMFG08BAG
NVSLCFG25BXG
NVSLCFG26BXG
NVSLCSG25BXG
NVSLCSG26BXG
NVSZMFG01BXG
NVSZMFG26BXG
NVSZMFG08BXG
NVSLCFG25BBG
NVSLCFG26BBG
NVSLCSG25BBG
NVSLCSG26BBG
NVSZMFG01BBG
NVSZMFG26BBG
NVSZMFG08BBG
NVSLCFG25CAG
NVSLCFG26CAG
NVSLCSG25CAG
NVSLCSG26CAG
NVSZMFG01CAG
NVSZMFG26CAG
NVSZMFG08CAG
NVSLCFG25CXG
NVSLCFG26CXG
NVSLCSG25CXG
NVSLCSG26CXG
NVSZMFG01CXG
NVSZMFG26CXG
NVSZMFG08CXG
NVSLCFG25CBG
NVSLCFG26CBG
NVSLCSG25CBG
NVSLCSG26CBG
NVSZMFG01CBG
NVSZMFG26CBG
NVSZMFG08CBG
3/4" Ceiling Amber Red Green Blue Clear
3/4" Wall Amber Red Green Blue Clear
NVS SERIES LIGHTING
L218
DIMENSIONS
CATALOG NO. DESCRIPTION
NVSLC LED SERIES1
COMPONENT/REPLACEMENT PARTS
NVSLCFG25A
NVSLCFG25R
NVSLCFG25G
NVSLCFG25B
NVSLCFG25C
NVSLCSG25A
NVSLCSG25R
NVSLCSG25G
NVSLCSG25B
NVSLCSG25C
NVSLCFG26A
NVSLCFG26R
NVSLCFG26G
NVSLCFG26B
NVSLCFG26C
NVSLCSG26A
NVSLCSG26R
NVSLCSG26G
NVSLCSG26B
NVSLCSG26C
NV2GG-S
NVSZMFG01
NVSZMFG08
NVSZMFG26
NVSZ-LAMP
NVSMA
NVSMR
NVSMG
NVSMB
NVSMC
NV2GG
NV2XG
NV2AG
NV2BG
NV2MG
LED BODY AMBR FLASH 120-240VAC
LED BODY RED FLASH 120-240VAC
LED BODY GRN FLASH 120-240VAC
LED BODY BLUE FLASH 120-240VAC
LED BODY CLR FLASH 120-240VAC
LED BODY AMBR STEADY 120-240VAC
LED BODY RED STEADY 120-240VAC
LED BODY GRN STEADY 120-240VAC
LED BODY BLUE STEADY 120-240VAC
LED BODY CLR STEADY 120-240VAC
LED BODY AMBR FLASH 12-80VDC: 24VAC
LED BODY RED FLASH 12-80VDC: 24VAC
LED BODY GRN FLASH 12-80VDC: 24VAC
LED BODY BLUE FLASH 12-80VDC: 24VAC
LED BODY CLR FLASH 12-80VDC: 24VAC
LED BODY AMBR STEADY 12-80VDC: 24VAC
LED BODY RED STEADY 12-80VDC: 24VAC
LED BODY GRN STEADY 12-80VDC: 24VAC
LED BODY BLUE STEADY 12-80VDC: 24VAC
LED BODY CLR STEADY 12-80VDC: 24VAC
NVSLC COMPACT LED GUARD
NVS XENON BODY WITH LAMP 120VAC
NVS XENON BODY WITH LAMP 240VAC
NVS XENON BODY WITH LAMP 12-80VDC; 24VAC
NVS XENON REPLACEMENT LAMP
NVS AMBER LENS & GASKET
NVS RED LENS & GASKET
NVS GREEN LENS & GASKET
NVS BLUE LENS & GASKET
NVS CLEAR LENS & GASKET
NVSZM MEDIUM XENON GUARD
NVS Ceiling/Wall Mtg Box
NVS Pendant Box
NVS Wall Elbow (use with NV2XG/NV2MG Box)
NVS M20 Ceiling/Wall Mtg Box
1BODY AND LENS W/O MOUNTING BOX OR GUARD
NVS MOUNTING BOXES3
3See NV2 series page L3 for additional information.
Pendant
NVSZ Xenon
NV2GG-S
Compact
Guard
NV2GG
Medium
Guard
Pendant
NVSL LED
Ceiling/Wall
NVSL LED
Wall
NVSL LED
Wall
NVSZ Xenon
Ceiling/Wall
NVSZ Xenon
3/4" NPT
3/4" NPT
TYPE 4
PLACES
3/4" NPT
TYPE 4
PLACES
.87
(22)
2.48
(63)
6.90
(175)
6.55
(166)
4.22 (107)
4.53 DIA (115) .33
(8) #8-32
Set Screw
2.48
(63)
11.55
(293)
9.26
(235)
3.00 DIA
(76)
7.26 (184)
7.26 (184)
1.15
(29)
1.15
(29)
4.38 DIA (262)
3.00 DIA (76)
4.38 DIA (262)
4.54 DIA (115)
12.6
(320)
10.32
(262)
7.96
(202)
7.60
(193)
2.12
(54)
1.15
(29)
4.53 DIA
(115)
5.94 (151)
5.19 (132)
45o
4.75
(121)
2.12
(54)
1.15
(29) 2.12
(54)
8.90
(226)
11.19
(284)
4.22 (107)
4.54 (115)
1.15
(29)
6.18
(157)
6.34
(166)
.33
(8) #8-32
Set Screw
3/4" NPT
(4) PLACES
90oAPART
3/4" NPT
TYPE 4
PLACES
NVSZM XENON SERIES2
2BODY AND POWER SUPPLY W/LAMP
4.38 (111)
3.00 DIA (76)
FKA/FM HOOK/LOOP LIGHTING
FIXTURE HANGERS L219
FEATURES-SPECIFICATIONS
L
FKA FH HOOKLOOP
FKA
Features
Ball joint permits fixture to hang
plumb. Fixture may swing up to 20°
from vertical in any direction
Cast of aluminum alloy (copper-free
aluminum; less than 4/10 of 1%)
Set screw locks fixture stem in place.
Cannot accidently loosen – intended
for use with threaded
metal conduit
Joint cannot twist conductor
Suitable for fixtures up to
125 pounds
FH
Features
Combination splice box and flexible
fixture hanger
Ball joint permits fixture to hang
plumb. Fixture may swing up to 20°
from vertical
Cast of aluminum alloy (copper-free
aluminum; less than 4/10 of 1%)
Set screw locks fixture stem in place –
intended for use with threaded
metal conduit
Joint cannot twist conductors
Cover may be removed for easy
wiring– 11 cu. inches
Mounts directly to metal conduit
Suitable for fixtures up to
125 pounds
HOOKLOOP
Features
Pendant fixture hanger consists of a
“HOOK” and safety bar which allows
conversion to a “LOOP” configuration
as necessary
3/4" male thread
Maximum load 125 pounds
CATALOG MALE FIXTURE
NUMBER THREAD STEM SIZE
FKA-22 3/4" 3/4"
FKA
CATALOG NUMBER
HOOKLOOP
HOOKLOOP
TWO HUBS THREE HUBS
FEED CONDUIT FIXTURE
THRU T SIZE STEM SIZE
FHC-21 FHT-21 3/4" 1/2"
FHC-22 FHT-22 3/4" 3/4"
F H
Listed - File E27731
Certified - File LR11851
See files for details or call Killark.
For replacement ball only
catalog number 00890545
Listed - File E27731
For replacement ball only
catalog number 00890545
Listed - File E27731
Certified - File LR11851
See files for details or call Killark.
FH/VX SERIES LIGHTING
FIXTURE HANGERS
L220
FEATURES-SPECIFICATIONS
Hook
VGA VGC
VGH VGX
Hub Covers
(for Rigid Mounting)
Flexible Hanger Covers
FH V Hanger Boxes Covers
FH HOOK
Features
Economical hanger for pendant
fixtures
Fixtures may absorb minor bumps
and vibration through free swinging
action
Hub provided with a set screw to pre-
vent accidental loosening of
fixture stem
A 1/2 inch hole in body is for flexible
cable. Cord may be assembled with
plug for quick removal of fixtures
Cast of aluminum alloy (copper-free—
less than 4/10 of 1%)
FH supports up to 125 pounds
V SERIES
Features
Flexible fixture hanger for threaded
fixture stem
Enclosed and gasketed, suitable for
wet locations
Permits angular displacement of
fixture without twisting wires
Cushioned—absorbs shock and
vibration. Internal strap assures
ground continuity
CATALOG NUMBER
HANGER W/SPLICE BOX SPLICE BOX ONLY HUB SIZE FIXTURE STEM SIZE
VPFHA-12 VGA-1 1/2" 3/4"
VPFHA-22 VGA-2 3/4" 3/4"
VPFHC-12 VGC-1 1/2" 3/4"
VPFHC-22 VGC-2 3/4" 3/4"
VPFHH-12 VGH-1 1/2" 3/4"
VPFHH-22 VGH-2 3/4" 3/4"
VPFHX-12 VGX-1 1/2" 3/4"
VPFHX-22 VGX-2 3/4" 3/4"
FLEXIBLE HANGERS, V SERIES ENCLOSED AND GASKETED
CATALOG FIXTURE
NUMBER DESCRIPTION STEM SIZE
FH-2 Hook 3/4"
FH HOOK, LOOP
CATALOG FIXTURE
NUMBER DESCRIPTION STEM SIZE
VPFH-2 Flexible hanger cover, 3/4"
maximum load 125 Lbs.
VG-2 Hub cover 3/4"
for rigid mounting
FIXTURE HANGERS ONLY
Listed - File E27731 or E3397
See files for details or call Killark.
Listed - File E27731 or E3397
Combines splice box and hanger in one
unit. Splice box available in four config-
urations
Cast of corrosion resistant aluminum
alloy (copper-free—less than 4/10 of
1%)
Supports up to 125 pounds
See page L11 for other box configurations.
Flexible cover with box, dotted line is VGA pen-
dant.
HXB/XFH/EKJ SERIES LIGHTING
FIXTURE HANGERS L221
FEATURES-SPECIFICATIONS
L
HXB XFH EKJ
HXB
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Features
Fixture hanger for hazardous locations
combining splice box and hanger
Set screws in female hub prevents
accidental loosening of fixture stem;
set screws in hub cover lock cover to
the splice box
Four hubs in “X” configuration up
to 3⁄4"
Flange mounting ring cast as integral
part of box
Splice box wiring hole with cover for
access to box interior
Cast of corrosion resistant aluminum
alloy (copper-free aluminum; less than
4/10 of 1%)
Supports to 125 pounds; vol. 16 cu.”
EKJ
Class I, Div. 1 & 2, Groups A,B,C,D
Class l, Zones 1 & 2, Groups
llC,llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Features
Fixture pendant hanger for
hazardous locations
Permits free swing and plumb hang
Set screws in each hub prevents acci-
dental loosening of fixture
Constructed of seamless bronze hose
with brass outer braid. Asphaltum
impregnated jute inner insulates and
protects wire from abrasion. Brass
female end fittings are supplied with
short nipples
Electrical ground continuity without
bonding jumper
Suitable for wet locations as well as
hazardous locations
Flexible lengths 4 to 18 inches
Supports to 125 pounds
XFH
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Features
Fixture hanger for hazardous locations
combining splice box and hanger
Set screws in female hub prevents
accidental loosening of fixture
Straight through conduit hubs for
through feed
Mounting lugs are standard
Cast of corrosion resistant aluminum
alloy (copper-free aluminum; less than
4/10 of 1%)
Supports to 125 pounds
Listed - File E10514
Certified - File LR11716
Listed - File E10514
Certified - File LR11716
Listed - File E10514
Certified - File LR11716
CATALOG CONDUIT FIXTURE
NUMBER HUB SIZE STEM SIZE
HXB-11 1/2" 1/2"
HXB-12 1/2" 3/4"
HXB-21 3/4" 1/2"
HXB-22 3/4" 3/4"
HXBC Blank Cover
HIC-SILVER Replacement Wiring Plug
HXB SPLICE BOX AND HANGER
CATALOG CONDUIT FIXTURE
NUMBER HUB SIZE STEM SIZE
XFH-21 3/4" 1/2"
XFH-22 3/4" 3/4"
XFH SPLICE BOX AND HANGER
CATALOG CONDUIT FIXTURE
NUMBER HUB SIZE STEM SIZE
EKJ-14 1/2" 4"
EKJ-24 3/4"
EKJ-16 1/2" 6"
EKJ-26 3/4"
EKJ-18 1/2" 8"
EKJ-28 3/4"
EKJ-110 1/2" 10"
EKJ-210 3/4"
EKJ-112 1/2" 12"
EKJ-212 3/4"
EKJ-115 1/2" 15"
EKJ-215 3/4"
EKJ-118 1/2" 18"
EKJ-218 3/4"
EKJ FLEXIBLE PENDANT HANGER*
*See page F67 for EKJ 1" sizes
JL/JAL/ENY SERIES LIGHTING
FIXTURE HANGERS
L222
FEATURES-SPECIFICATIONS
JL JAL ENY Pendant Seal
JL/JAL
Class I, Div. 1 & 2, Groups C,D
Class l, Zones 1 & 2, Groups llC,llB
Class II, Div. 1 & 2, Groups E,F,G
Class III
Features
Splice box and hub cover for mount-
ing pendant fixtures in hazardous
locations
Conduit openings in two configura-
tions
Flange type cover. Set screw in hub
prevents accidental loosenings of
fixture stem
Integral lugs for mounting box to ceiling
Cast of corrosion resistant aluminum
alloy (copper-free aluminum; less than
4/10 of 1%)
Supports up to 125 pounds
ENY PENDANT SEALS
Class I, Div. 1 & 2, Groups A,B,C,D
Class l, Zones 1 & 2, Groups llC,llB,llA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Features
ENY Pendant Seals are designed for
hazardous locations and meet code
requirements for a safety set-screw
when hanging fixtures. Common appli-
cations are for Class l Division l Group
B or Class l Zone 2 Ex nR restricted
breathing fixtures
Cast of corrosion resistant aluminum
alloy (copper-free aluminum; less than
4/10 of 1%)
Supports up to 125 pounds
See page F48 for sealing compound and
packing fiber
Listed - File E10514
Certified - File LR11716
CATALOG NUMBER
JL SERIES JAL SERIES CONDUIT BOX COVER TYPE
W/HUB COVER W/HUB COVER
JLC-11 1/2" 1/2"
JLC-12 1/2" 3/4"
JLC-21 3/4" 1/2"
JLC-22 3/4" 3/4"
JLX-11 JALX-11 1/2" 1/2"
JLX-12 JALX-12 1/2" 3/4"
JLX-21 JALX-21 3/4" 1/2"
JLX-22 JALX-22 3/4" 3/4"
JALX-31 1" 1/2"
JALX-32 1" 3/4"
JL/JAL SPLICE BOX AND HUB COVER FIXTURE HANGER
C
Straight
Through
X
Four
Hubs
SERIES ABCD EH
JL 1-15/16" 11/16" 3-1/4" 4-7/32" 2-3/8" 5/16"
(49) (17) (95) (107) (60) (8)
JAL 2-3/8" 15/32" 4-5/8" 5-1/4" 4-1/8" 5/16"
(60) (12) (117) (133) (105) (8)
JL/JAL DIMENSIONS
CATALOG NUMBER SIZE
ENY-2SET 3/4"
ENY-3SET 1"
VM SERIES LIGHTING
COMPETITIVE ADAPTER L223
FEATURES-SPECIFICATIONS
L
Class I, Div. 2, Groups A,B,C,D
Class I, Zone 2, Groups IIC, IIB, IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
NEMA 3, 4, 4X
Certified
Applications
VMCHVM adapters are designed to
ease upgrading of existing Crouse-
Hinds®VM,LM,DM” series fixtures to
Killark “VM” CERTILITE®fixtures. Units
are primarily designed to aid replace-
ment of old ceiling or wall mount units
where removal of the existing mounting
box and conduit would be difficult or
time consuming. Adapter & Killark fix-
tures rated NEMA 4.
Adapters allow the upgrade of older
Mercury Vapor fixtures to newer HID
lamp sources, Compact Fluorescent
Lamps, LED Induction or to Emergency
Lighting.
Series included are VQ1F, VQ2F, VE3Q,
VE3V, VE4Q and VM1L.
Note: Adapters are used with Fixture
Ballast Tanks (plus globes & guards),
e.g. VM3S150, VMG17, VMAG17.
Complete fixture with mounting splice
box is not required. Adapters are paint-
ed to match Killark beige fixture finish.
Features
Allows use of CertiLite®V’s patented
Swing-Barrel nut for ease of mainte-
nence. Attaches to Crouse-Hinds®
mount with hinge and set screw.
Temperature codes:
See Certilite®V or VM series product
pages or as listed with other desired
product series.
CATALOG DESCRIPTION EXAMPLE OF MODEL
NUMBER UTILIZED OR REPLACED
Crouse ceiling mount or wall mount splice box.
VMCHXM Adapter allows simple attachment of Killark ballast tank Ceiling mounts CM2, CM3
to existing mount. Wall mounts TWM2, TWM3
Existing mount
Adapter
Existing box
VMCHVM adapter shown
in red for illustration
New Killark VM series
fixture
VM COMPETITIVE ADAPTER
2.59"
Note - To use the adaptor ring
in assemblies using CertiLite®V
housings, substitute RC for
the MOUNT code.
Example: VM3S150X2GLG
Becomes VM3S150RCGLG
EAC/EACH/EZBA SERIES LIGHTING
FIXTURE ADAPTERS
L224
FEATURES-SPECIFICATIONS
EAC/EACH EZBA12
Class I, Div. 1 & 2, Group D
Class I, Zones 1 & 2, Groups IIA
Class II, Div. 1 & 2, Groups E,F,G
Class III
Applications
EAC Series adapters are designed to
ease upgrading of existing Crouse-
Hinds®“EV” series or existing Killark “H”
series to Killark HOSTILELITE®EM or EZ
series. Units are primarily designed to
aid replacement of old ceiling or wall
mount units where removal of the exist-
ing mounting box and conduit would be
difficult or time consuming. Adapter &
Killark fixtures rated NEMA 4.
Adapters allow the upgrade of older
incandescent fixtures to newer
Fluorescent or HID lamp sources, or
to Emergency Lighting including ESX
strobes or EEQ emergency series.
Note: Adapters are used with Fixture
Housing, Globe, Globe Support assem-
blies, e.g. EBF261 & EMG1; EMS151 &
EMG2; or EZH100 & EZG1. Complete
fixture with mounting box is not required.
Adapters are painted to match Killark
beige fixture finish.
Features
Setscrews permit secure adapter
attachment into old mounting box and
to new fixture
Converted fixtures may be easily
removed for service using the Killark
EZ mounting system. Wire terminals
are included in the adapter (EZTB
Terminal Block)
Temperature codes:
See EM/EB/EQ series pages L144 to
L145
EZ series pages L164 to L165
ESX series pages L214 to L215
EEQ series page L211
CATALOG DESCRIPTION EXAMPLE OF MODEL
NUMBER UTILIZED OR REPLACED
EAC Killark “H” series Ceiling or Wall HXG-2-125 Fixture
EACH12 Crouse old style Ceiling Mount with lamp socket in
adapter ring between fixture body and a GUF 12 pitch box “GUF” box w/Set Screw
Crouse old style Wall Mount, old style Arm with integral
EZBA12 lamp socket (socket in fixture in newer models) attached “GUF” box w/Set Screw
to GUF 12 pitch mounting box. EZBA12 includes arm
Crouse newer style ceiling or wall fixtures w/lamp socket in
EACH16 fixture body; mounted to EV series 16 pitch threaded box; EVA26/EV22 Box; EVBX240
adapter fits in ceiling box or existing arm attached to wall fixture
2.31" 2.38"
3.30"
7.38"
11.91"
11.11"
Existing
mount
Existing
mount
Existing box & conduit
Fixture
body
Supply
leads
EACH12 or
EACH16 adapter
EACH12 or EACH16 adapter
shown in red for illustration
New Killark EM or EZ series
fixture
EZTB terminal
block (typical)
EAC/EZBA FIXTURE ADAPTERS
Certified
See Hubbell Website
For More Listings:
www.hubbell.com
HUBBELL INC. Corporate Headquarters 584 Derby Milford Rd. Orange, CT 06477
Our brands are all long established and well respected businesses within each of their industries,. To find out more about a specific brand visit
the websites listed.
H U B B E L L E L E C T R I C A L S Y S T E M S
Austdac Bryant Electric Burndy LLC Chalmit Lighting
Ph: +61(2)8851 5000 Ph: 800-323-2792 Ph: 603-647-5000 Ph: +44(0)141 882 5555
www.austdac.com.au www.hubbell-bryant.com www.burndy.com www.chalmit.com
GAI-Tronics- United Kingdom GAI-Tronics - USA Gleason Reel Corporation Haefely Test AG
Tel: +44(0)1283 500500 Ph: 800-492-1212 Ph: 920-387-4120 Ph: +41 61 373 41 11
www.gai-tronics.org.uk www.gai-tronics.com www.hubbell-gleason.com www.haefely.com
Haefely Test EMC AG Hawke International Hawke International-USA Hipotronics
Ph: +41 61 373 41 11 Ph: +44 0161 308 3611 Ph: 800-354 9189 Ph: 845-279-8091
www.haefelyemc.com www.ehawke.com www.ehawke.com www.hipotronics.com
Hubbell Industrial Controls, Inc. Hubbell Marine Electrical Products Hubbell Premise Wiring Hubbell Wiring Device-Kellems
Ph: 336-434-2800 Ph: 203-882-4900 Ph: 800-626-0005 Ph: 203-882-4800
www.hubbell-icd.com www.hubbell-wiring.com www.hubbell-premise.com www.hubbell-wiring.com
Killark Pulsecom RACO BELL Tettex Instruments
Ph: 314-531-0460 Ph: 800-381-1997 Ph: 800-722-6437 Ph: +41 61 373 4422
www.hubbell-killark.com www.pulse.com www.hubbell-raco.com www.tettex.com
Transtar Victor Lighting Wiegmann Wirecon
Ph: 0141 810 9666 Ph: +44 (0) 141 810 9644 Ph: 618-539-3193 Ph: (800) 323-2792
www.transtargear.co.uk www.victor-lighting.com www.hubbell-wiegmann.com www.bryant-electric.com/Wirecon.aspx
HUBBELL LIGHTING
Alera Lighting Architectural Area Lighting Beacon Products Columbia Lighting
Ph: 864-678-1000 Ph: 714-994-2700 Ph: 800-345-4928 Ph: 864-678-1000
www.aleralighting.com www.aal.net www.beaconproducts.com www.columbialighting.com
Compass Products Devine Lighting Dual-Lite HomeStyle Lighting
Ph: (864)-678-1000 Ph: 864-678-1000 Ph: (864)-678-1000 Ph: 864-678-1000
www.compasslightingproducts.com www.devine-ltg.com/index.php www.dual-lite.com www.homestyle-ltg.com
Hubbell Building Automation Hubbell Industrial Lighting Hubbell Outdoor Lighting Kim Lighting
Ph: 888-698-3242 Ph: 864-678-1000 Ph: 864-678-1000 Ph: 626-968-5666
www.hubbellautomation.com www.hubbellindustrial.com www.hubbelloutdoor.com www.kimlighting.com
Kurt Versen Precision-Paragon [P2] Prescolite Progress Lighting
Ph: 201-664-8200 Ph: (714) 386-5550 Ph: (864)-678-1000 Ph: 864-678-1000
www.kurtversen.com www.p-2.com www.prescolite.com www.progresslighting.com
Security Lighting Systems Spaulding Lighting Sportsliter Solutions (SLS) Sterner Lighting Systems Whiteway
Ph: 800-544-4848 Ph: (864)-678-1000 Ph: 864-678-1000 Ph: (864)-678-1000 Ph: 800-544-4848
www.securitylightingsystems.com www.spauldinglighting.com www.sportslighting.com www.sternerlighting.com www.whiteway-ltg.com
H U B B E L L P O W E R S Y S T E M S
Anderson Atlas CDR Chance
Ph: 573-682-5521 Ph: 573-682-8414 Ph: 386-615-9510 Ph: 573-682-5521
www.hubbellpowersystems.com/about/anderson
www.abchance.com/about/atlas.asp www.cdrsystems.com
www.hubbellpowersystems.com/about/chance-civil
Electro Composites Fargo Mfg. Company, Inc. Hubbell Cable Accessories Hubbell Power Systems
Ph: 450-430-1181 Ph: 573-682-5521 Ph: 573-682-5521 Ph: 573-682-5521
www.eci-co.com/energy-products/apparatus-bushings.aspx www.hubbellpowersystems.com/about/fargo www.hubbellpowersystems.com/about/cable-accessories
www.hubbellpowersystems.com
Ohio Brass PCORE Electric Polycast Quazite USCO
Ph: 573-682-5521 Ph: (585) 768-1200 Ph: 800-346-3061 Ph: 800-346-3062 Ph: (205) 699-0840
www.hubbellpowersystems.com/about/ohio-brass
www.pcoreelectric.com
www.polycastdrain.com www.quazite.com
www.uscopower.com
INTERNATIONAL
Hubbell Canada Hubbell de Mexico UK Hubbell Products
Ph: 905-839-1138 Ph: (01 52) 559-151-9999 Ph: +44 (0) 1283 500500
www.hubbell-canada.com www.hubbell.com.mx www.hubbell.co.uk
Electrical Construction
Products For Standard, Harsh
and Hazardous Locations
Hubbell Electrical Systems
A Division of Hubbell, Inc. (Delaware)
Chalmit • Hawke • Killark • Raco/Bell • Wiegmann
KL-CATALOG-2011 © 2 0 1 1 H u b b e l l E l e c t r i c a l S y s t e m s P r i n t e d i n U . S . A .
3940 M. L. King Dr.
St. Louis, MO 63113
TEL: (314) 531-0460 FAX: (314) 531-7164
www.hubbell-killark.com
Hubbell Canada, Inc.
870 Brock Road South
Pickering, Ontario L1W-1Z8
(905) 839-1139
Hubbell De Mexico
Av. Coyoacan 1051
Col. Del Valle
Mexico, D.F. 03100
001-5255-9151-9999