INSTALLATION INSTRUCTIONS
KING Electrical Mfg. Company • 9131 10th Avenue South • Seattle, WA 98108 • Ph: 206.762.0400 • Fax: 206.763.7738 • www.king-electric.com
SAVE THESE INSTRUCTIONS
1. After removing the heater from the carton check to make sure the heater has not been damaged in shipment.
2. Remove the grill by loosening and removing the four screws on the side of the front panel.
3. Detach the interior from the wall can by removing the four screws along each side of the interior. Remove the interior
by tilting it away from the wall can to release the bottom edge.
4. Remove one 7/8" knockout and feed the supply wire into the wall box using an approved electrical fitting to prevent
chafing of the supply wires.
5. Install the wall can a minimum of 6" from vertical side walls or open edge of door and 10" above the floor.
6. Secure the wall box to 2x4 studs using the holes provided in the sides of the box. The face of the wall box should be
flush with the finished wall.
7. Make electrical connections per the wiring diagram. Supply wires L1 and L2 can be connected to the red or black
wires on the heater - the order does not matter. Attach the field groundwire to the green screw or pigtail. When
installing a built-in thermostat red always connects to the supply wires and black to the heater.
8. Install interior by placing the bottom edge in the wall can and tilting it in toward the wall. Be sure to clear the electrical
wires on the side of the interior. Fasten the interior and then the grill with the screws provided.
9. The installation is now complete and the heater is ready to be energized for use.
EFW - Large Fan Wall Heater
SAFETY LIGHT: This heater includes
a visual alarm to warn that parts of the
heater are getting excessively hot. If
the alarm flashes, immediately turn the
heater off and inspect for any objects on
or adjacent to the heater that may cause
high temepratures. Do not operate the
heater with the alarm flashing.
ATTENTION: Before attempting to install your heater verify that the power supply wires are the same voltage as the heater
being installed. 240 and 120 Volt heaters are not interchangeable. Connecting a 240 Volt heater to a 120 Volt circuit will
reduce the wattage 75% and cause the motor to rotate slowly, significantly reducing airflow. Connecting a 120 Volt heater to
a 240 Volt circuit will destroy the heater, void all warranties and could cause fire damage.
WARNING: Turn off power source to the heater before attempting installation, maintenance or repairs. Lock, tape or tag
circuit breaker or fuse so that power cannot be turned on by accident. Falure to do so could result in personal injury.
EFW.indd : 4/08
11½"
FAN-FORCED HEATERS:
Clearances for Safe
Operation
INSTALLATION INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Maintenance & Warranty Information:
The high quality and superior design of this heater will
provide years of trouble-free performance. Each year the
heater should be checked and cleaned for lint and dust
accumulation. We recommend using a soft bristled brush
such as a paint brush to assist in removing contaminants
from the heater.
Limited One Year Warranty:
King Mfg. Co. will repair or replace without charge any King
product found to be defective or malfunctioning
during
the
first year of purchase to the original owner.
Wiring Diagram
Dimension Chart
L2
L1 Red
Black
Red
Blk
Blk
Optional Thermostat
Single Pole
Blk
Blk
Blk
Safety
Light
Terminal
Block
TN1
M2 N2
E4
Fan
Motor
M1
L
E2
E1
E3
Blk
Blk
Blk
Blk
Blk
White
White
Elements
Limit Control
Elements
Ground
SELECTION CHART
CATALOG
NO.VOLTS WATTAGE AMPS
EFW1220
120
2000 16.6
EFW1224 2400 20
EFW1230 3000 25
EFW2020
2420
208
240
2000 9.6
EFW2030
2430
3000 14.4
EFW2040
2440
4000 19.2
KING Electrical Mfg. Company • 9131 10th Avenue South • Seattle, WA 98108 • Ph: 206.762.0400 • Fax: 206.763.7738 • www.king-electric.com