15599 Sec.8 12/9/01 11:17 AM Page 256
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Motor Control Explosionproof Circuit Breakers - Disconnect Switches

8B–1

EXPLOSIONPROOF AND DUST-IGNITIONPROOF
CLASS I, GROUPS B, C & D: CLASS II, GROUPS E, F & G;
NEMA 7 & 9
BREAKERS: Circuit breakers are thermal magnetic type and
are available in frame sizes ranging from 15 to 1200
amperes. Also available as non-automatic circuit interrupters,
without automatic overload trip elements for load switching
and isolation. In this application short circuit and overload
protection must be provided by separate protection device.
Breakers also available for magnetic trip only.
The units can be set up for GE, Cutler-Hammer
(Westinghouse), Square-D and ITE (Siemens) brand circuit
breakers. Consult factory for other brands. Holes for CutlerHammer circuit breakers are drilled directly into back wall.
ENCLOSURES: The housings are copper-free cast
aluminum alloy. The enclosures are Adalet XCE series with
precision ground cover and body joints.
The enclosure design offers sufficient space for wire
bending and ease of installation and maintenance. XCBC
and larger units are furnished with hinges, and stainless
steel cover bolts. The covers are removable for clear access
to breakers. For XCBA and XCBB units, hinge and mounting
pan are optional.
The front mounted circuit breaker handle is padlockable in
either “on” or “off” position.

Optional XCBH 2-2 handle shown;
standard handle is XBO.

High interrupting capacity breakers are also available in
comparable size.

Approvals:
Enclosure Certifications

E81696

Compliances:
Class I, Groups B, C, D
Class II, Groups E, F, G
NEMA 4, 7, 9
UL Classified Enclosure

Optional XCBH Style
“Classic”, larger handle.
Special 1" – 11 1/2" NPSM opening
required for installation.
Enclosure

Standard XBO Style
“New”, spring loaded, compact
adjustable design, ease of assembly
and less expensive.
Standard 3/4 – 14 NPSM opening
required for installation.

UL Classified
Enclosure Rating

XCBA, XCBB, XCBC, XCBD, XCBE, XCBF,
XCBG

Class 1, Grps BCD

XCBA N4, XCBB N4, XCBC N4, XCBD N4,
XCBE N4, XCBF N4, XCBGN4

Class 1, Grps CD

256
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 257
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Motor Control Explosionproof Circuit Breakers - Disconnect Switches

Molded Case Circuit Breaker Enclosures (Breaker Included)
Breaker

Frame

Interrupting

Size

Rating

Catalog No.
Volts

14,000

100/150

3 Pole

Rating

Non-Interchangeable

Non-Interchangeable

15

XCBA-N4-15E42*

XCBA-N4-15E43*

20

XCBA-N4-20E42*

XCBA-N4-20E43*

30

XCBA-N4-30E42*

XCBA-N4-30E43*

40

XCBA-N4-40E42*

XCBA-N4-40E43*

50

XCBA-N4-50E42*

XCBA-N4-50E43*

480

60

XCBA-N4-60E42*

XCBA-N4-60E43*

Interrupting

Volt AC

70

XCBA-N4-70E42*

XCBA-N4-70E43*

Capacity

250

80

XCBB-N4-80E42*

XCBB-N4-80E43*

at 480

Volt DC

90

XCBB-N4-90E42*

XCBB-N4-90E43*

100

XCBB-N4-100E42*

XCBB-N4-100E43*

110

XCBB-N4-110E42*

XCBB-N4-110E43*

125

XCBB-N4-125E42*

XCBB-N4-125E43*

150

XCBB-N4-150E42*

XCBB-N4-150E43*

15

XCBA-N4-15E62*

XCBA-N4-15E63*

20

XCBA-N4-20E62*

XCBA-N4-20E63*

30

XCBA-N4-30E62*

XCBA-N4-30E63*

40

XCBA-N4-40E62*

XCBA-N4-40E63*

14,000
Amperes

600

50

XCBA-N4-50E62*

XCBA-N4-50E63*

Interrupting

Volt AC

60

XCBA-N4-60E62*

XCBA-N4-60E63*

Capacity

250

70

XCBA-N4-70E62*

XCBA-N4-70E63*

at 600

Volt DC

Volt AC

18,000

225/250

2 Pole

Amperes

Volt AC

100/150

Catalog No.

Amp

80

XCBB-N4-80E62*

XCBB-N4-80E63*

90

XCBB-N4-90E62*

XCBB-N4-90E63*

100

XCBB-N4-100E62*

XCBB-N4-100E63*

110

XCBB-N4-110E62*

XCBB-N4-110E63*

125

XCBB-N4-125E62*

XCBB-N4-125E63*

150

XCBB-N4-150E62*

XCBB-N4-150E63*

70

XCBC-N4-70JN2*

XCBC-N4-70JN3*

90

XCBC-N4-90JN2*

XCBC-N4-90JN3*

Amperes

600

100

XCBC-N4-100JN2*

XCBC-N4-100JN3*

Interrupting

Volt AC

125

XCBC-N4-125JN2*

XCBC-N4-125JN3*

Capacity

250

150

XCBC-N4-150JN2*

XCBC-N4-150JN3*

at 600

Volt DC

Volt AC

* Circuit breaker brand suffix:
W-Cutler-Hammer (Westinghouse)

175

XCBC-N4-175JN2*

XCBC-N4-175JN3*

200

XCBC-N4-200JN2*

XCBC-N4-200JN3*

225

XCBC-N4-225JN2*

XCBC-N4-225JN3*

250

XCBC-N4-250JN2*

XCBC-N4-250JN3*

G-General Electric

S-Square-D

8B–2

Breaker

T-I.T.E. (Siemens)

257
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 258
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Motor Control Explosionproof Circuit Breakers - Disconnect Switches
Molded Case Circuit Breaker Enclosures (Breaker Included)
Breaker

Breaker

Frame

Interrupting

Catalog No.

Size

Rating

Volts

8B–3

22,000

400

3 Pole

Rating

Non-Interchangeable

Non-Interchangeable

100

XCBD-N4-100KN2*

XCBD-N4-100KN3*

125

XCBD-N4-125KN2*

XCBD-N4-125KN3*

150

XCBD-N4-150KN2*

XCBD-N4-150KN3*

175

XCBD-N4-175KN2*

XCBD-N4-175KN3*

600

Interrupting

Volt AC

200

XCBD-N4-200KN2*

XCBD-N4-200KN3*

Capacity

250

225

XCBD-N4-225KN2*

XCBD-N4-225KN3*

at 600

Volt DC

250

XCBE-N4-250KN2*

XCBE-N4-250KN3*

300

XCBE-N4-300KN2*

XCBE-N4-300KN3*

350

XCBE-N4-350KN2*

XCBE-N4-350KN3*

400

XCBE-N4-400KN2*

XCBE-N4-400KN3*

250

XCBE-N4-250LI2*

XCBE-N4-250LI3*

300

XCBE-N4-300LI2*

XCBE-N4-300LI3*

22,000
Amperes

600

Interrupting

Volt AC

350

XCBE-N4-350LI2*

XCBE-N4-350LI3*

Capacity

250

400

XCBE-N4-400LI2*

XCBE-N4-400LI3*

at 600

Volt DC

500

XCBF-N4-500LI2*

XCBF-N4-500LI3*

600

XCBF-N4-600LI2*

XCBF-N4-600LI3*

Volt AC

800

2 Pole

Amperes

Volt AC

600

Catalog No.

Amp

22,000

600

400

XCBF-N4-400MI2*

XCBF-N4-400MI3*

Amperes

Volt AC

500

XCBF-N4-500MI2*

XCBF-N4-500MI3*

Interrupting

250

600

XCBF-N4-600MI2*

XCBF-N4-600MI3*

Capacity

Volt AC

700

XCBF-N4-700MI2*

XCBF-N4-700MI3*

800

XCBF-N4-800MI2*

XCBF-N4-800MI3*

at 600 Volt AC

Note: For Interchangeable Trip substitute an “I” for “N” in the Catalog Number.
(Example: XCBC-N4-70JI2)

Fusible Disconnect Switches
Horsepower

Horsepower

Rating

Rating

Amp

Catalog No.

at 480 Volts

at 600 Volts

Rating

3 Pole

20

20

30

XCBA-N4-30DF3*

40

50

60

XCBA-N4-60DF3*

75

75

100

XCBB-N4-100DF3*

125

150

200

XCBC-N4-200DF3*

Note: (3) Class “J” fuses are optional in the above catalog numbers.
* Circuit breaker brand suffix:
W-Cutler-Hammer (Westinghouse)

G-General Electric

S-Square-D

T-I.T.E. (Siemens)

258
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 259
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Motor Control Explosionproof Circuit Breakers - Disconnect Switches
Non-Fused Disconnect Switches
Horsepower

Rating

Rating

Amp

at 480 Volts

at 600 Volts

Rating

Catalog No.
3 Pole

20

25

30

XCBA-N4-30DN3

40

60

60

XCBA-N4-60DN3

75

75

100

XCBB-N4-100DN3

125

150

200

XCBC-N4-200DN3

8B–4

Horsepower

Circuit Breaker Enclosure Only
Breaker Frame Size

Trip Range

Catalog Number

100

15-70

XCBA-N4

100/150

80-150

XCBB-N4

225/250

70-250

XCBC-N4

400

100-225

XCBD-N4

400/600

250-400

XCBE-N4

600/800

400-800

XCBF-N4

1200

800-1200

XCBG-N4

CIRCUIT BREAKERS and DISCONNECT OPTIONS
Description

Suffix

Auxiliary Switch 1A and 1B Contacts
Auxiliary Switch 2A and 2B Contacts
Bell Alarm (Specify No. of Contacts)
Breather/Drain - installed in bottom
Breather and Drain installed
High Interrupting Capacity Breaker
Epoxy Coating (External), (Specify Color)
Epoxy Coating (Internal and External), (Specify Color)
Substitute MCP for Breaker
Phenolic Nameplate (Specify Legend)
Shunt Trip (Specify Voltage Rating)
Undervoltage Release (Specify Voltage Rating)
Other / Special

AS1
AS2
BA
E
EE
HI
LI
L2
M
NP
ST
UV
Z

Available On
Circuit
Disconnect
Breaker
Switch

•
•
•
•
•
•
•
•
•
•
•
•
•

Universal
Enclosure
Only

•
•
•
•
•
•
•

•
•
•
•
•

•

Data Dimensions

Enclosure

Width

Nominal Inside

Overall

Mounting

Mounting

Conduit

Dimensions

Dimensions

CL to CL

Bolt

Dimension

Length

Depth

A

B

C

E

F

Size

D

Conduit

Shipping

# of Holes

Weight

G

Size

Top/Bottom

Pounds

XCBA-N4

6

11

5

9 1/4

14 1/4

9

9 1/8

7 1/2

7/16

2 1/2

—

1 1/4

1

28

XCBB-N4

6

13

5

9 1/4

16 1/4

9

9 1/8

9 1/2

3/8

2 1/2

—

2

1

31

XCBC-N4

7

18

5

10 3/8

21 5/8

9

9 3/4

14 1/2

3/8

2 3/4

—

2 1/2

1

47

XCBD-N4

12

20

5

16 1/4

24 1/4

10

15 3/4

14 3/8

1/2

3 1/4

2 1/2

1

108

XCBE-N4

12

24

6

16 1/4

28 1/4

11

15 3/4

18 3/8

1/2

3 5/8

—
2 7/8

3

2

131

XCBF-N4

12

36

8

16 1/4

40 1/4

13 1/2

15 3/4

29

5/8

4 1/2

3 3/8

4

2

237

XCBG-N4

12

46

8

16 1/4

50 1/4

13 3/8

15 3/4

39

5/8

4 1/2

3 3/8

4

2

286

All enclosures have 1/2" NPT top and bottom for breather drain.

259
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 180
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XDF Custom Enclosure Systems For Digital Instrumentation

Applications
Environments requiring explosionproof or dust-tight
enclosures.
Housing for panel mounted instrumentation with or
without external operator functions – can
accommodate standard DIN or other size devices.

Examples
• Flow Meters
• Level Indicators
• Motion Controllers
• Temperature Monitors
• Gas Analyzers

Features
• Space saving rectangular design
• Enclosure dimensions customized to match the
instrument
• A range of rectangular window openings
• Choice of quantity and location of miniature
operators including “key pad” configuration
• Front or rear accessibility for instrument service
• Watertight NEMA 4 gasketing
• Choice of surface finishes
• Recessed Allen Head cover bolts for appearance
and security

4B–1

• Special nameplating and escutcheon available.

Availability & Support
Adalet engineering will review your specific
requirements.
Adalet offers design support, custom dimensional
layout, product prototyping, testing and certification
assistance.
Production scheduling and inventory to match
defined needs.
Custom sizes available, consult factory for details.

Certifications
FM STANDARD 3615
CSA STANDARD C22.2 NO. 30

NEMA 4, 7CD, 9E, F & G
NEC Class I, Division I, Groups C & D
Class II, Groups E, F & G
NEMA 4, 7CD, 9E, F, & G

180
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 241

7C–1

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Factory-Sealed Control Stations
F

B E

C

D
A

Dimensions
Dimensions in Inches
XFSA3223

XFSA3911

XFSA3185
A
4 1/4

Features and Benefits
• Factory-sealed control stations eliminate the need for poured seals
• All control stations have 3/4" feed-through conduit entries
• Factory-sealed contact block rated NEMA A600 and NEMA Q300
• All selector switches have lock-out capabilities
• Bodies and covers are cast from lightweight, corrosion-resistant,
copper-free aluminum
• High-quality legend plates permit easy identification of device function
• Durable cast-on lugs cannot get lost

B
8

C
4 11/16

D
2 5/8

E
7 1/8

F
11/32

Certifications/Compliances
Cover Assembly
Body Assembly
Complete Enclosure Assembly
Class I, Division 1, Groups B* CD
Class I, Division 2, Groups BCD†
Class I, Zone 1, Group IIB
Class I, Zone 2, Group IIB
NEMA 4 Option:
Class I, Division 1, Groups C & D
Class I, Division 2, Groups BCD†
Class I, Zone 1, Group IIB
Class I, Zone 2, Group IIB

• Ground screw is highly visible and accessible
• Strong, durable materials for reliability and safety
• Customization of box entries available – please consult factory
• NEMA 4 option available – please consult factory

Class II, Division 1, Groups E, F & G
Class II, Division 2, Groups E, F & G†

Material/Finish

NEMA 3, 3R, 4, 7CD, 9EFG, 12

Body, Cover: Copper-Free Aluminum
Operator and Pilot Light Bodies: Anodized Aluminum
Operator Shaft: Stainless Steel
Levers: Aluminum

Contact BlockOnly
Class I, Division 1, Groups BCD (recognized)
Class I, Division 2, Groups BCD (listed)
Class I, Zone 1, Group IIB+H2
Class I, Zone 2, Group IIB+H2

Application
A wide variety of control stations may be assembled from Adalet bodies,
devices and covers for use indoor or outdoor where Class I or Class II hazards
are present, such as petroleum refineries, chemical plants and grainprocessing and storage facilities. XFS Control Stations may be used in
conjunction with magnetic starters or contactors for remote control of motors.

Applicable Standard
Underwriters Laboratories:
UL 698, UL 1203
*Group B pending
†Division 2 Compliance

Catalog No.

Control Station Description

XFSA3101

Black momentary pushbutton

XFSA3223

Start-stop momentary pushbuttons

XFSA3911

Maintained emergency stop with mushroom head

XFSA3173

2-position, 2-circuit selector switch with 1NO/1NC contact

XFSA3185

2-position, 4-circuit selector switch with 2NO/2NC contacts

XFSA3178

3-position, 2-circuit selector switch with 1NO/1NC
contact marked HAND-OFF-AUTO

XFSA31208

Green pilot light

XFSA31209

Red pilot light

XFSA32089

One green and one red pilot light

XFSA30925

Red pilot light with start-stop momentary dual pushbutton

241
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 242
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

7C–2

OmniStar Specifications

Features and Benefits
• Factory sealed control station eliminates the need for poured seals
• Factory sealed contact block rated NEMA A600 and NEMA Q300
• Single-station through four-gang vertical or horizontal configurations are available to
accommodate a wide variety of system needs
• Conduit entries available in 1/2", 3/4" and 1" sizes either dead-end or feed through
• Customization possible by using any of a wide variety of devices: pilot lights, miniature
operators, momentary contact pushbuttons, selector switches, key operator selector
switches or rocker arm
• One- through four-hole covers allow up to four NO/NC contact blocks per station
• Bodies and covers are cast from lightweight, corrosion-resistant, copper-free aluminum
• High-quality legend plates permit easy identification of device function
• Durable cast-on lugs cannot get lost
• Ground screw is highly visible and accessible
• Strong, durable materials for reliability and safety
• Customization of box entries available – please consult factory
• NEMA 4 option available – please consult factory

Material/Finish
Body, Cover: Copper-Free Aluminum
Operator and Pilot Light Bodies: Anodized Aluminum
Operator Shaft: Stainless Steel
Knobs: Nylon

Application
A wide variety of control stations may be assembled from Adalet bodies, devices and
covers for use indoor or outdoor where Class I or Class II hazards are present, such as
petroleum refineries, chemical plants and grain processing and storage facilities. XFS
Control Stations may be used in conjunction with magnetic starters or contactors for
remote control of motors.

Certifications/Compliances
XFSC Cover Assembly
XFSB Body Assembly
LISTED
XFSA Complete Enclosure Assembly
Class I, Division 1, Groups CD
Class I, Division 2, Groups B*CD†
Class I, Zone 1, Group IIB
Class I, Zone 2, Group IIB
NEMA 4 Option:
Class I, Division 1, Groups C & D
Class I, Division 2, Groups C & D†
Class I, Zone 1, Group IIB
Class I, Zone 2, Group IIB
Class II, Division 1, Groups E, F & G
Class II, Division 2, Groups E, F & G†
NEMA 3, 3R, 4, 7CD, 9EFG, 12

Contact Block
Only

LISTED

Class I, Division 1, Groups BCD (recognized)
Class I, Division 2, Groups BCD (listed)
Class I, Zone 1, Group IIB+H2
Class I, Zone 2, Group IIB+H2

Applicable Standard
Underwriters Laboratories: UL 698, UL 1203

*Group B Compliance
†Division 2 Compliance

242
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 243

7C–3

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

OmniStar Bodies & Covers

Table A1 Conduit Entry
A

Hole Location Suffix Numbers
Conduit
Entry

Catalog Suffix No.

Top

Bottom

Left

1/2"
3/4"
1"

2
3
4

A
A
A

B
B
B

C
1
C
C

1

Replacement Body
Catalog No.

Right
1

D
1
D
D

C

XFSB2
XFSB3
XFSB4

D

B

1 Catalog suffix number followed by hole location suffix (C&D holes always 1" NPT)
Example – 3ACD would be a body with a 3/4" hole in the top position and two 1" holes on the sides.
Note: When ordering assembled control station, catalog number should begin with XFSA to indicate body
and cover. Refer to page 7D–6 for catalog logic/example.

Table B1 Covers
Style

Catalog Suffix No.

NEMA Type 4
Catalog Suffix No.

Replacement Cover
2
Catalog No.

NEMA Type 4
Replacement Cover
2
Catalog No.

–
1
2
3
4
5
RA

-N4
1-N4
2-N4
3-N4
4-N4
5-N4
RA-N4

XFSC
XFSC-1
XFSC-2
XFSC-3
XFSC-4
XFSC-5

XFSC-N4
XFSC-1-N4
XFSC-2-N4
XFSC-3-N4
XFSC-4-N4
XFSC-5-N4

Blank
One 3/4" NPSM Hole
Two 3/4" NPSM Holes
One 3/4" NPSM Hole and Two 3/8-16” UNC Holes
Four 3/8-16" UNC Holes
Two 3/8-16" UNC Holes
Rocker Arm — See next page

2 Replacement cover catalog numbers should be followed by suffix numbers for Adalet operators.
Example – XFSC-4-N4 would be a NEMA Type 4 cover with four holes.

XFSC-1

XFSC-2

XFSC-4

XFSC-3

XFSC-5

243
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 244
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

7C–4

OmniStar Device Kits – Pushbuttons & Pilot Lights

Table C1 Pushbuttons
Catalog
Suffix Nos.
for 1 NO/1 NC

Kit
Momentary Pushbutton – Black
Momentary Pushbutton – Green
Momentary Pushbutton – Red
Momentary PB w/ Padlock – Black
Momentary PB w/ Padlock – Green
Momentary PB w/ Padlock – Red
Mushrm Hd Momentary PB – Black
Mushrm Hd Momentary PB – Green
Mushrm Hd Momentary PB – Red
Mushrm Hd Maintained
Mushrm Hd Maintained
Lighted Pushbutton – Amber2
Lighted Pushbutton – Blue2
Lighted Pushbutton – Clear2
Lighted Pushbutton – Red2
Lighted Pushbutton – White2
Dual PB Momentary – “Start/Stop”
Dual PB Momentary – Green/Red
Dual PB Momentary – Black/Black
Dual PB w/ Lockout – “Start/Stop”
Dual PB w/ Lockout – Green/Red
Dual PB w/ Lockout – Black/Black
Dual PB Maint – “Start/Stop”
Dual PB Maint – Green/Red
Dual PB Maint – Black/Black
Dual PB Maint w/ Lockout – “Start/Stop”
Dual PB Maint w/ Lockout – Green/Red
Dual PB Maint w/ Lockout – Black/Black
Rocker Arm 2 NO/2 NC1

Use Suffix “0” for 3/4" NPSM plug and Suffix “00” for 3/8" UNC
plug to fill unused spaces. For collars different in color than
pushbutton ordered, consult factory.

Catalog
Suffix Nos.
for 2 NO/2 NC

1F
2F
3F
4F
5F
6F
7F
8F
9F
911F

10F
11F
12F
13F
14F
15F
16F
17F
18F
912F

1F

9F

25F
26F
27F
28F
29F
30F
31F
32F
34F
35F
36F
37F
RA1

23F

25F

20F
21F
22F
23F
24F

1 For Rocker Arm 3 NO/3 NC, use suffix RA2 andfor Rocker Arm 4 NO/4 NC, use suffix RA3.
2 Not for use in NEMA 4 applications

61F

Contact Ratings OmniStar
AC
Volts
Make & Interrupting Capacity
Normal Load Break
Continuous Current
Catalog No.

FSBT

A
A
A

110
60
6
10

220
30
3
10

DC
440
15
1.5
10

550
12
1.2
10

120
.55
.55
2.50

440
.27
.27
2.50

One Normally Open and One Normally Closed.

Table D1 Pilot Lights

Lens Color

Suffix Nos. for
Guarded Pilot Lt.
Candelabra Base

Suffix Nos. for
Guarded Pilot Lt.
Slide Base

Suffix Nos. for
Miniature Pilot
Lights

Amber
Blue
Clear
Green
Red
White

205F
206F
207F
208F
209F
210F

215F
216F
217F
218F
219F
220F

201F

202F
203F

244
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 245

7C–5

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

OmniStar Device Kits – Selector Switches
Table E1 Selector Switches

Selector Switch

Cam

Suffix Nos. for
Mounting Position A
1 NO/1 NC

1
2
3
4
5
6
1
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
2
3
4
5
6
1
2
3
4
5
6

51F
52F
53F
54F
55F
56F
73F
74F
75F
76F
77F
78F
91F
92F
93F
94F
95F
106F
107F
108F
109F
110F
122F
123F
124F
125F
126F
138F
139F
140F
141F
142F
153F
154F
155F
156F
157F
168F
169F
170F
171F
172F
183F
184F
185F
186F
187F
188F

Selector Switch
Selector Switch
Selector Switch
Selector Switch
Selector Switch
Selector Switch
Selector Switch with Padlock
Selector Switch with Padlock
Selector Switch with Padlock
Selector Switch with Padlock
Selector Switch with Padlock
Selector Switch with Padlock
Selector Switch with Spring Return Center Right to Left
Selector Switch with Spring Return Center Right to Left
Selector Switch with Spring Return Center Right to Left
Selector Switch with Spring Return Center Right to Left
Selector Switch with Spring Return Center Right to Left
Selector Switch with Spring Return Center from Right
Selector Switch with Spring Return Center from Right
Selector Switch with Spring Return Center from Right
Selector Switch with Spring Return Center from Right
Selector Switch with Spring Return Center from Right
Selector Switch with Spring Return Center from Left
Selector Switch with Spring Return Center from Left
Selector Switch with Spring Return Center from Left
Selector Switch with Spring Return Center from Left
Selector Switch with Spring Return Center from Left
Key Selector Switch with Spring Return Center Right to Left
Key Selector Switch with Spring Return Center Right to Left
Key Selector Switch with Spring Return Center Right to Left
Key Selector Switch with Spring Return Center Right to Left
Key Selector Switch with Spring Return Center Right to Left
Key Selector Switch with Spring Return Center from Right
Key Selector Switch with Spring Return Center from Right
Key Selector Switch with Spring Return Center from Right
Key Selector Switch with Spring Return Center from Right
Key Selector Switch with Spring Return Center from Right
Key Selector Switch with Spring Return Center from Left
Key Selector Switch with Spring Return Center from Left
Key Selector Switch with Spring Return Center from Left
Key Selector Switch with Spring Return Center from Left
Key Selector Switch with Spring Return Center from Left
Key Selector Switch
Key Selector Switch
Key Selector Switch
Key Selector Switch
Key Selector Switch
Key Selector Switch

Suffix Nos. for
Suffix Nos. for
Mounting Position B Mounting Position AB
1 NO/1 NC
2 NO/2 NC
61F
62F
63F
64F
65F
66F
79F
80F
81F
82F
83F
84F
96F
97F
98F
99F
100F
111F
112F
113F
114F
115F
127F
128F
129F
130F
131F
143F
144F
145F
146F
147F
158F
159F
160F
161F
162F
173F
174F
175F
176F
177F
189F
190F
191F
192F
193F
194F

MOUNTING
POSITION A

Contact Sequence Chart
2-Position
Selector
Switches
Cam 1
Contact
Sequence

O = Contact Open
X = Contact Closed
Circuit of Contact Block

67F
68F
69F
70F
71F
72F
85F
86F
87F
88F
89F
90F
101F
102F
103F
104F
105F
116F
117F
118F
119F
120F
132F
133F
134F
135F
136F
148F
149F
150F
151F
152F
163F
164F
165F
166F
167F
178F
179F
180F
181F
182F
195F
196F
197F
198F
199F
200F

3-Position Selector Switches
Cam 2
Cam 3
Cam 4
Contact
Contact
Contact
Sequence Sequence Sequence

Cam 5
Cam 6
Contact
Contact
Sequence Sequence

Mounting
Position

Normally Closed (NC)
Normally Open (NO)

A

Normally Closed (NC)
Normally Open (NO)

B

Circuit A
Circuit B

XO
OX

XX O
OO X

X XO
OOX

XOX
OXO

OOX
X XO

OOX
OXO

Circuit A
Circuit B

XO
OX

OX O
XO X

OXX
X OO

XOO
OX X

OXX
X OO

XOO
OOX

MOUNTING
POSITION B

VIEWED
FROM BACK

POSITIONS A AND B TO BE
DETERMINED AT INSTALLATION

245
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:15 AM Page 246
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

7C–6

OmniStar Dimensions – Vertical & Horizontal 4-Gang Assembly

L
K
J

R
B

E

Q

F
D
A

F

P
C

B

E

HORIZONTAL 4-GANG ASSEMBLY

C

D
A

VERTICAL 4-GANG ASSEMBLY

Dimensions
Dimensions in Inches

A
4 1/4

B
8

4

C

D

E

F

J

K

11/16

2 5/8

7 1/8

11/32

7 5/16

14 5/8

L
21

15/16

P
9 1/8

Q

R

18 1/4

27 3/8

246
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:15 AM Page 247

7C–7

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

OmniStar Ordering Information

To Order
To order control stations, determine the number of
operators required. Select the control station body and
cover by operator quantity and mounting type from Tables
A1 and B1. Order operators by suffix numbers from
Tables C1, D1 and E1. Add suffix numbers to box/cover
assembly number (replacing the “B” in the box catalog
number with an “A” for “Assembly” followed by a

number to indicate the number of holes in the cover),
separating the assembly number from the suffix
number(s) by dashes. All operator holes must be filled by
an operator or plug. Installation of operators will be made
in the following order: upper left, upper right, lower left,
lower right. See Assembly Catalog Numbers Logic/Example
below. Select legend plates from Table F1 below.

Table F1 Legend Plate Standard Markings
Pushbuttons/Pilot Lights
Blank
Start
Inch
Stop
Run
Forward
Reverse
Fast

Slow
Open
Close
Up
Jog
On
Off
Back

Selector Switches
Reset
In
Out
Left
Right
Low
High
Down
E-Stop

Run-Jog
Hand-Auto
Forward-Reverse
Fast-Slow
Open-Close
Up-Down
Off-On

Open-Off-Close
Fast-Off-Slow
Run-Auto-Jog
Hand-Off-Auto
Forward-Off-Reverse
1-Off-2
Up-Off-Down

Legend Plates are anodized
aluminum with engraved letters on
black background.
Stop has red and start has green
background.
Special engraved legend plates can
be supplied.

Assembly Catalog Numbers Logic/Example

X

F

S

BOX AND COVER
ASSEMBLY

A

2
3
4

A
B
C
D

CONDUIT HOLE SIZE
*HOLE LOCATIONS
IN BOX

1
2
3
4
5
RA

–
SUFFIX NUMBERS
(FILLING HOLES UPPER LEFT,
UPPER RIGHT, LOWER LEFT,
LOWER RIGHT)

XFSA2A1-1F is an
assembled control
station with one 1/2"
hub, and one operator
hole with one
momentary pushbutton
black.

COVER

*C & D holes are always supplied as 1" NPT

247
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:21 AM Page 293
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories

EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES
CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
MULTI-HUB BOXES
Designed for general wiring in hazardous locations. For pulling and splicing
conductors. Serves as mounting outlets with use of appropriate fixture
covers.
Available with dome cover for additional splicing room and mounting of
various devices.

Bodies XJAB, XJAD and XJAX 26 thru 46 have two interior mounting
bosses, which can be blind tapped.
Bodies XJAC, XJAL and XJAT 26 thru 46 have four interior mounting
bosses, which can be blind tapped.
All bodies 570 thru 890 have solid back, can be tapped blind.
Conduit
Size (In.)

Standard Pkg.
Quantity

Standard Pkg.
Weight Lbs.

XJAB-26

1/2

10

9

XJAB-36

3/4

10

10

XJAB-46

1

10

12

XJAB-570

1 1/4

5

25

XJAB-690

1 1/2

4

22

XJAB-890

2

4

23

XJAC-26

1/2

10

9

XJAC-36

3/4

10

10

XJAC-46

1

10

12

XJAC-570

1 1/4

5

26

XJAC-690

1 1/2

4

21

XJAC-890

2

4

23

XJAD-36

3/4

10

9

XJAD-46

1

10

15

XJAL-26

1/2

10

9

XJAL-36

3/4

10

10

XJAL-46

1

10

12

XJAL-570

1 1/4

5

26

XJAL-690

1 1/2

4

21

XJAL-890

2

4

23

10A–1

Catalog
Number

Compliances
• NEC Class I, Groups C, D
Class II, Groups E, F, G

NEMA 4 WATERTIGHT OPTIONAL:
Consult factory for availability and/or
certifications.

• UL Standard 886 - CSA Standard
C22.2 No. 30
293

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:21 AM Page 294
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories

EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES
CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
MULTI-HUB BOXES

XJAL
(No bottom hub)

Catalog
Number

Conduit
Size (In.)

Standard Pkg.
Quantity

Standard Pkg.
Weight Lbs.

XJAT-26

1/2

10

10

XJAT-36

3/4

10

10

XJAT-46

1

10

13

XJAT-570

1 1/4

5

27

XJAT-690

1 1/2

4

21

XJAT-890

2

4

23

XJAX-26

1/2

10

12

XJAX-36

3/4

10

14

XJAX-46

1

10

15

XJAX-570

1 1/4

5

27

XJAX-690

1 1/2

4

21

XJAX890

2

4

23

10A–2
XJAT
(No bottom hub)

XJAX
(No bottom hub)

Compliances
• NEC Class I, Groups C, D
Class II, Groups E, F, G

NEMA 4 WATERTIGHT OPTIONAL:
Consult factory for availability and/or
certifications.

• UL Standard 886 - CSA Standard
C22.2 No. 30

294
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:21 AM Page 295
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories

EXPLOSIONPROOF AND DUST-TIGHT JUNCTION BOXES
CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
MULTI-HUB BOXES
BLANK COVERS
Catalog
Number

Description

St. Pkg.

Std. Pkg.
Weight Lbs.

XJA6

For 1/2" – 3/4" – 1" Bodies

10

5

XJA8

For 1 1/4" – 1 1/2" – 2" Bodies

5

11

SEALING COVERS
XJA6

Catalog
Number

Description

St. Pkg.

Std. Pkg.
Weight Lbs.

XJA6S

For 1/2" – 3/4" – 1" Bodies

10

7

10A–3

Entire body must be filled with sealing compound. NEC
prohibits splices and taps in sealing fittings.
DOME COVERS
Catalog
Number

XJA6S

Description

St. Pkg.

Std. Pkg.
Weight Lbs.

XJADC

For 1/2" – 3/4" – 1" Bodies
Inside Depth 2 3/8"

10

9

XJAD4

For 1 1/4" – 1 1/2" – 2" Bodies
Inside Depth 4 1/8"

1

5

XJAD6

For 1 1/4" – 1 1/2" – 2" Bodies
Inside Depth 6"

1

6

XJAD10

For 1 1/4" – 1 1/2" – 2" Bodies
Inside Depth 10"

1

8 1/2

XJAD13

For 1 1/4" – 1 1/2" – 2" Bodies
Inside Depth 13"

1

9 1/2

XJAO

O-Ring For NEMA 4 watertight
For 1/2" – 3/8" – 1" Bodies

1

—

XJTO

O-Ring for NEMA 4 watertight
For 1 1/4" – 1 1/2" – 2" Bodies

1

—

XJADC

295
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:21 AM Page 296
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT SEALING FITTINGS
CLASS I, GROUPS B*, C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9

Sealing Fittings are required in Hazardous Locations and are used to
isolate arc-producing devices in conduit and wiring systems, and to
prevent the passage of explosive pressures from one area to another.
FOR HORIZONTAL AND VERTICAL MOUNTING - Type XYB and XYBM
are suitable for either horizontal or vertical mounting and are provided
with threaded plugged openings into which fiber and cement can be
placed to form effective seal. XYB has female ends for conduit entrance.
The XYBM has female ends with a removable threaded nipple.
*1/2”, 3/4”, 1” sizes Class I, Group B, C, D, Class II, E, F, G.
XYB-XYBM

1 1/4”, 1 1/2”, 2”, 2 1/2”, 3”, 3 1/2”, 4” sizes Class I, Group C, D
Class II, E, F, G

CSA Certified LR27991
UL Listed E10493

10A–4

Catalog No.
Description

Conduit
Size (In.)

Ounces Req. For
Each Sealing Fitting
Cement
Fiber

Standard
Package
Qty.
Tot. Wt. Lbs.

Female-Female

Catalog No.
Description

Conduit
Size (In.)

Ounces Req. For
Each Sealing Fitting
Cement
Fiber

Standard
Package
Qty.
Tot. Wt. Lbs.

Male-Female

XYB-2

1/2

1

1/8

5

2.1

XYBM-2

1/2

1

1/8

5

XYB-3

3/4

2

1/4

5

2.6

XYBM-3

3/4

2

1/4

5

2.7

XYB-4

1

3

1/4

5

3.7

XYBM-4

1

3

1/4

5

3.8

XYB-5

1-1/4

6

3/8

2

2.5

XYBM-5

1-1/4

6

3/8

2

2.6

XYB-6

1-1/2

9

1/2

2

3.2

XYBM-6

1-1/2

9

1/2

2

3.4

XYB-8

2

18

3/4

2

5.6

XYBM-8

2

18

3/4

2

5.9

XYB-10

2-1/2

23

1-1/2

2

6.2

XYBM-10

2-1/2

23

1-1/2

2

6.8

XYB-12

3

48

3-1/8

1

6.0

XYBM-12

3

48

3-1/8

1

6.3

XYB-14

3-1/2

70

4-1/2

1

6.8

XYBM-14

3-1/2

70

4-1/2

1

7.3

XYB-16

4

90

6

1

8.3

XYBM-16

4

90

6

1

8.8

2.2

Nominal Dimensions (Inches)
Conduit
Size

(XYBM Series Only)
D

C

Turn
Radius R

A

B

1/2

3-19/32

1-13/16

5/8

11/16

1-3/16

3/4

3-25/32

2-1/16

3/4

15/16

1-5/16

1

4-3/8

2-5/16

7/8

15/16

1-7/16

1-1/4

5-5/32

2-13/16

1-1/16

1-1/16

1-3/4

1-1/2

5-11/16

3-3/16

1-3/16

1-3/16

2

2

6-13/16

3-7/8

1-1/2

1-7/16

2-3/8

2-1/2

7-1/2

4-1/2

1-7/8

1-5/8

2-11/16

3

9-9/16

5-1/2

2-3/16

1-7/8

3-5/16

3-1/2

9-1/2

6-1/6

2-3/8

2

3-11/16

4

9-9/16

6-1/2

2-5/8

2-1/8

3-7/8

Compliances
• NEC Class I, Groups B, C, D
Class II, Groups E, F, G
• UL Standard 886 - CSA Standard
C22.2 No. 30

296
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:21 AM Page 297
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT 40% FILL SEALING FITTINGS
CLASS I, GROUPS B*, C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Sealing Fittings are used for the same application as the standard
Adalet sealing fitting but allow up to 40% wire fill in the fitting.
*1/2”, 3/4” sizes Class I, Group B, C, D, Class II, E, F, G.
1”, 1-1/4”, 1-1/2”, 2”, 2-1/2”, 3” sizes Class I, Group C, D,
Class II, E, F, G.

XYB-XYBM

CSA Certified LR27991

Catalog No.
Description

Conduit
Size (In.)

Ounces Req. For
Each Sealing Fitting
Cement
Fiber

Standard
Package
Qty.
Tot. Wt. Lbs.

Catalog No.
Description

Conduit
Size (In.)

Ounces Req. For
Each Sealing Fitting
Cement
Fiber

Standard
Package
Qty.
Tot. Wt. Lbs.

Male-Female

Female-Female
XYB-34

1/2

2

1/4

5

2.6

XYBM-34

1/2

2

1/4

5

2.7

XYB-44

3/4

3

1/4

5

3.7

XYBM-44

3/4

3

1/4

5

3.8

XYB-54

1

6

3/8

2

2.5

XYBM-54

1

6

3/8

2

2.6

XYB-84

1-1/4

18

3/4

2

5.6

XYBM-84

1-1/4

18

3/4

2

5.9

XYB-104

1-1/2

23

1-1/2

2

6.2

XYBM-104

1-1/2

23

1-1/2

2

6.8

XYB-124

2

48

3-1/8

1

6.0

XYBM-124

2

48

3-1/8

1

6.3

XYB-144

2-1/2

70

4-1/2

1

6.8

XYBM-144

2-1/2

70

4-1/2

1

7.3

XYB-164

3

90

6

1

8.3

XYBM-164

3

90

6

1

8.8

Nominal Dimensions (Inches)
Conduit
Size

A

B

C

(XYBM Series Only)
D

Turn
Radius R

1/2

3-25/32

2-1/16

3/4

15/16

1-5/16

3/4

4-3/8

2-5/16

7/8

15/16

1-7/16

1

5-5/32

2-13/16

1-1/16

1-1/16

1-3/4

1-1/4

6-13/16

3-7/8

1-1/2

1-7/16

2-3/8

1-1/2

7-1/2

4-1/2

1-7/8

1-5/8

2-11/16

2

9-9/16

5-1/2

2-3/16

1-7/8

3-5/16

2-1/2

9-1/2

6-1/16

2-3/8

2

3-11/16

3

9-9/16

6-1/2

2-5/8

2-1/8

3-7/8

Compliances
• NEC Class I, Groups B, C, D
Class II, Groups E, F, G
• UL Standard 886 - CSA Standard C22.2 No. 30
297
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

10A–5

UL Listed E10493

15599 Sec.10 12/9/01 11:21 AM Page 298
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT SEALING FITTINGS
CLASS I, GROUP D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Adalet Sealing Fittings are used to isolate arc-producing devices from wiring
systems and to prevent the spread of explosive gases.

XY 2-3-4

XYM 2-3-4

FOR VERTICAL MOUNTING
Types XY and XYM Fittings are for vertical mounting, and are provided with
threaded plugged openings into which the sealing cement is poured. Sizes
1-1/4” x 1-1/2” have large plugged openings in the lower hub to facilitate
packing fiber around the wires to form a dam. Type XYM’s have removable
threaded nipples. The two hubs are tapped simultaneously to assure
alignment of the conduits, especially important to equipment manufacturers
using short runs of conduit.
FOR HORIZONTAL & VERTICAL MOUNTING
Type XYC Fittings are for horizontal mounting only, with the cover opening
in an upright position. XYCS fittings are for vertical or horizontal mounting,
with removable threaded covers which can be turned to the desired
position for pouring in the sealing cement. The covers are interchangeable.
The male-to-female types have removable threaded nipple.

10A–6

Catalog Number

XY 5-6

XYC

XYM 5-6

XYCM

Ounces
Required per Fitting

Standard Package

Female/
Female

Male/
Female

Conduit
Size
(In.)

XY2

XYM2

1/2

1

1/8

25

XY3

XYM3

3/4

1

1/4

25

10

XY4

XYM4

1

2

1/4

25

12-1/2

XY5

XYM5

1-1/4

4

3/8

10

7-1/2

XY6

XYM6

1-1/2

5

1/2

10

10

XYC2

XYC2M

1/2

2

1/8

25

13

XYC3

XYC3M

3/4

2

1/4

25

13

XYC4

XYCM4

1

4-1/2

1/4

25

15

XYC5

XYC5M

1-1/4

8-1/2

3/8

10

10

XYC6

XYC6M

1-1/2

11-1/2

1/2

10

11

Sealing
Cement

Packing
Fiber

Qty

Weight
Lbs.
10

XYC8

XYC8M

2

13-1/2

3/4

10

12

XYC10

XYC10M

2-1/2

15

1-1/2

1

2

XYC12

XYC12M

3

31-1/2

3-1/8

1

3

XYC14

XYC14M

3-1/2

42-1/2

4-1/2

1

4

XYC16

XYC16M

4

51

6

1

5

XYC2S

XYC2SM

1/2

2

1/8

25

13

XYC3S

XYC3SM

3/4

2

1/4

25

13

XYC4S

XYC4SM

1

3

1/4

25

15

XYC5S

XYC5SM

1-1/4

6-1/2

3/8

10

10

XYC6S

XYC6SM

1-1/2

10

1/2

10

11

XYC8S

XYC8SM

2

12-1/2

3/4

10

12

XYC10S

XYC10SM

2-1/2

13-1/2

1-1/2

1

2

XYC12S

XYC12SM

3

29-1/2

3-1/8

1

3

Compliances

XYC14S

XYC14SM

3-1/2

40

4-1/2

1

4

• NEC Class I, Group D Class II, Groups E, F, G
• UL Standard 886 - CSA Standard C22.2 No. 30

XYC16S

XYC16SM

4

48-1/2

6

1

5

XYCS

XYCSM

CSA Certified LR27991
UL Listed E10493

298
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 299
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT 40% FILL SEALING
FITTINGS CLASS I, GROUP D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9

Adalet 40% Fill Sealing Fittings are used
for the same applications as the standard
Adalet Sealing Fittings, but allow up to
40% wire fill in the fitting.

XY 54

XYC 34XYC 164

XYC 34SXYC 164S

XYM 34, 44

Catalog Number

XYM 54

XYC 34MXYC 164M

Ounces
Required per Fitting

Standard Package

Female/
Female

Male/
Female

Conduit
Size
(In.)

XY34

XYM34

1/2

1

1/4

25

10

XY44

XYM44

3/4

2

1/4

25

12-1/2
7-1/2

Sealing
Cement

Packing
Fiber

Qty

Weight
Lbs.

XY54

XYM54

1

4

3/8

10

XYC34

XYC34M

1/2

2

1/4

25

13

XYC44

XYC44M

3/4

4-1/2

1/4

25

15

XYC54

XYC54M

1

8-1/2

3/8

10

10

XYC84

XYC84M

1-1/4

13-1/2

3/4

10

12

XYC104

XYC104M

1-1/2

15

1-1/2

1

2

XYC124

XYC124M

2

31-1/2

3-1/8

1

3

XYC144

XYC144M

2-1/2

42-1/2

4-1/2

1

4

XYC164

XYC164M

3

51

6

1

5

XYC34S

XYC34SM

1/2

2

1/4

25

13

XYC44S

XYC44SM

3/4

3

1/4

25

15

XYC54S

XYC54SM

1

6-1/2

3/8

10

10

XYC84S

XYC84SM

1-1/4

12-1/2

3/4

10

12

XYC104S

XYC104SM

1-1/2

13-1/2

1-1/2

1

2

XYC124S

XYC124SM

2

29-1/2

3-1/8

1

3

XYC144S

XYC144SM

2-1/2

40

4-1/2

1

4

XYC164S

XYC164SM

3

48-1/2

6

1

5

XYC 34SMXYC 164SM

Compliances
• NEC Class I, Group D
Class II, Groups E, F, G
CSA Certified LR27991

• UL Standard 886 - CSA Standard
C22.2 No. 30

UL Listed E10493

299
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

10A–7

XY 34, 44

15599 Sec.10 12/9/01 11:22 AM Page 300
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT SEALING FITTINGS
CLASS I, GROUP D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Dimensions (In.)
Catalog Number

10A–8
CSA Certified LR27991
UL Listed E10493

R = Turning

Nominal Dimensions, (In.)

Radius (Inches)

Female/
Female

Male/
Female

Conduit
Size

A

B

C

D

XY2

XYM2

1/2

3-1/16

2-7/16

3/4

11/16

1-13/16

XY3

XYM3

3/4

3-1/16

2-7/16

3/4

1

1-13/16

XY4

XYM4

1

3-3/4

2-15/16

15/16

15/16

2-1/8

XY5

XYM5

1-1/4

4-15/16

3-3/16

1-3/16

1-1/8

2-1/8

E

Plain
Cover

Sealing
Cover

XY6

XYM6

1-1/2

4-7/8

3-7/16

1-5/16

1-5/16

XYC2

XYC2M

1/2

3-1/16

2-9/16

2-1/6

5/8

13/16

1-7/8

2-11/16

XYC2S

XYC2SM
3/4

3-1/6

2-9/16

2-1/16

15/16

13/16

1-7/8

2-11/16

1

3-11/16

2-11/16

2-3/8

15/16

1

2-1/8

3-1/16

1-1/4

4-1/2

3-3/16

3-3/8

1-1/16

7/8

2-11/16

3-1/16

1-1/2

4-1/2

3-7/16

3-3/8

1-1/8

7/8

2-11/16

3-1/16

2

4-11/16

4

3-3/8

1-3/8

7/8

3

3-5/16

2-1/2

5-5/16

4-5/8

3-3/8

1-5/8

7/8

3-1/4

3-3/4

3

6-7/16

5-7/16

3-15/16

1-3/4

1-3/8

4

4-5/8

3-1/2

6-9/16

6-3/8

4-3/4

1-5/8

1-5/16

4-5/8

5

4

6-15/16

6-13/16

4-3/4

2

1-5/16

4-3/4

5-3/8

XYC3

XYC3M

XYC3S

XYC3SM

XYC4

XYC4M

XYC4

XYC4SM

XYC5

XYC5M

XYC5S

XYC5SM

XYC6

XYC6M

XYC6S

XYC6SM

XYC8

XYC8M

XYC8S

XYC8SM

XYC10

XYC10M

XYC10S

XYC10SM

XYC12

XYC12M

XYC12S

XYC12SM

XYC14

XYC14M

XYC14S

XYC14SM

XYC16

XYC16M

No
Cover

2-1/4

ADACO SEALING CEMENT AND ADACO PACKING FIBER
CLASS I, GROUPS B, C & D; CLASS II,
GROUPS E, F & G; NEMA 7 & NEMA 9

XSC

XAF

Catalog No.

Description

XSC-8

ADACO No. 1

Net Weight
8 oz.

XSC-16

Sealing

16 oz.

XSC-160

Cement

10 lbs.
1-1/2 oz.

XAF-6

ADACO

XAF-24

Packing

6 oz.

XAF-64

Fiber

1 lb.

ADACO SEALING CEMENT is the easiest-to-use sealing cement on the market. The
powder is contained in a polyethylene bag within an outer container. To mix, remove
the bag of powder, fill the outside container with water up to the marked “water line”
and pour in the powder. Simple...no guesswork about how much water to use. The
mixing container is right there...and clean. The largest unit package offered contains
one pound of powder. The XSC-160 (10-pound quantity) consists of 10, one-pound
packages (at the ten-pound price) so that every mix is correct. This cement has been
especially prepared for use in Adalet Sealing Fittings. It is not an insulating compound,
and is not affected by gasoline, alcohol, benzol, oils, acetone or lacquer solvents.
ADACO PACKING FIBER is used with Adaco Sealing Cement for plugging conduit
openings in fittings. Alumina Silica based long fiber non-asbestos for use as a packing
at the hubs of sealing units to prevent the Sealing Cement in the liquid state from
entering the conduit lines. The Fiber is tamped between the wires and the hub before
the Sealing Cement is poured into the fitting.

300
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 301
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT 40% FILL SEALING FITTINGS
CLASS I, GROUP D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9

R = Turning

Nominal Dimensions, (In.)

Radius (Inches)

Female/
Female

Male/
Female

Conduit
Size

A

XY34

XYM34

1/2

3-1/6

2-7/16

3/4

1

XY44

XYM44

3/4

3-3/4

2-15/16

15/16

15/16

3-1/8

XY54

XYM54

1

4-15/16

3-3/16

1-3/16

1-1/8

2-1/8

XYC34

XYC34M

1/2

3-1/6

2-9/16

2-1/16

15/16

13/16

1-7/8

2-11/16

XYC34S

XYC34SM
3/4

3-11/16

2-11/16

2-3/8

15/16

1

2-1/8

3-1/16

1

4-1/2

3-3/16

3-3/8

1-1/16

7/8

2-11/16

3-1/16

1-1/4

4-11/16

4

3-3/8

1-3/8

7/8

3

3-5/16

1-1/2

5-5/16

4-5/8

3-3/8

1-5/8

7/8

3-1/4

3-3/4

2

6-7/16

5-7/16

3-15/16

1-3/4

1-3/8

4

4-5/8

2-1/2

6-9/16

6-3/8

4-3/4

1-5/8

1-5/16

4-5/8

5

3

6-15/16

6-13/16

4-3/4

2

1-5/16

4-3/4

5-3/8

XYC44

XYC44M

XYC4S

XYC44SM

XYC54

XYC54M

XYC54S

XYC54SM

XYC84

XYC84M

XYC84S

XYC84SM

XYC104

XYC104M

XYC104S

XYC104SM

XYC124

XYC124M

XYC124S

XYC124SM

XYC144

XYC144M

XYC144S

XYC144SM

XYC164

XYC164M

XYC164S

XYC164SM

B

C

D

10A–9

Dimensions (In.)
Catalog Number

E

Plain
Cover

Sealing
Cover

No
Cover
1-13/16

301
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 302
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT
SHORT RADIUS PULL ELBOWS
CLASS I, GROUP D; CLASS II, GROUPS E, F & G; NEMA 7 & 9
This versatile and inexpensive explosion-proof fitting with a threaded
cover will easily and compactly handle 90° conduit runs. FL series have
two female entrances. MFL series has one female entrance and one
removable threaded nipple.
Nominal Dimensions Inches

FL

MFL

10A–10

Compliances
• NEC Class I, Group D
Class II, Groups E, F, G

Catalog
Number

Conduit
Size (In.)

FL92
FL93

Standard Package
Weight
Pounds

A

B

C

Quantity

1/2

2-5/8

2-1/8

1-3/8

25

8

3/4

2-13/16

2-1/8

1-1/2

25

10-1/2
11

FL94

1

3-1/4

2-7/16

1-7/8

25

FL95

1-1/4

3-3/4

3-1/2

2-1/4

25

24

*FL96

1-1/2

4-5/8

4-3/16

2-5/8

25

30

MFL92

1/2

2-5/8

2-1/8

1-3/8

25

9

MFL93

3/4

2-13/16

2-1/8

1-1/2

25

12
13

MFL94

1

3-1/4

2-7/16

1-7/8

25

MFL95

1-1/4

3-3/4

3-1/2

2-1/4

25

26

*MFL96

1-1/2

4-5/8

4-3/16

2-5/8

25

34

* Fitting not UL Listed or CSA Certified

• UL Standard 886 - CSA Standard C22.2 No. 30

CSA Certified LR27991
UL Listed E10493

EXPLOSIONPROOF AND DUST-TIGHT REMOVABLE PLUGS
CLASS I, GROUPS A, B, C & D; CLASS II, GROUPS E, F & G;
NEMA 7 & NEMA 9
Tapered thread close-up plugs for explosionproof conduit entrances. Provides
5 full threads of engagement. Made of aluminum alloy, these plugs have
screw-driver slots and fit practically flush when installed.

Standard Package

OX

Weight
Pounds

Standard Package

Catalog
Number

Conduit
Size (In.)

Catalog
Number

Conduit
Size (In.)

Qty

OX2

1/2

250

6-3/4

OX8

2

50

12

OX3

3/4

250

10-1/4

OX10

2-1/2

50

20-1/2
30

Qty

Weight
Pounds

OX4

1

150

9

OX12

3

50

OX5

1-1/4

100

12

OX14

3-1/2

50

40

OX6

1-1/2

100

14-1/2

OX16

4

50

52

302
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 303
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT CONDUIT UNIONS
CLASS I, GROUPS A, B, C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Explosionproof unions for use in conduit piping systems for ease of
installation and removal of fittings, boxes and equipment enclosures in
hazardous atmosphere areas. Parts are steel, cadmium plated for corrosion
protection. Style XU has two female NPT threads. Style XUM has two
female NPT threads and one plated threaded nipple.

Standard Package
Conduit
Size

Qty

Weight
Pounds

XU2

1/2”

XU3

3/4”

Female-Female

50

19

Female-Female

50

XU4

1”

21

Female-Female

25

13-1/2

XUM2
XUM3

1/2”

Female-Male

50

22

3/4”

Female-Male

50

XUM4

26

1”

Female-Male

25

16-1/2

10A–11

XU

Catalog
Number

DIMENSIONS
Conduit
Size

A

B

Series

1/2”

1-3/4”

1-1/2”

XU

3/4”

1-3/4”

1-3/4”

1”

1-15/16”

2”

Series

1/2”

2-9/16”

1-1/2”

XUM

3/4”

2-3/4”

1-3/4”

1”

3”

2”

XUM

Compliance
• NEC Class I, Groups A, B, C, D
Class II, Groups E, F, G
• UL Standard 886 - CSA Standard C22.2 No.30

CSA Certified LR27991
UL Listed E10493

303
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 304
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT FLEXIBLE COUPLINGS
*CLASS I, GROUPS A, B, C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Application: XFC couplings are for use in Hazardous Atmospheres where a flexible connection
is required for motor and equipment installation where movement and vibration are present.
Also for difficult bends and connections.
Material: Brass and bronze end fittings. Bronze wire flexible braid covering over flexible bronze
core with insulating liner. INCLUDES TWO REMOVABLE ZINC CLEAR COATED NIPPLES.
NOTE: For stainless steel in 1/2" and 3/4" sizes add SS suffix (XFCSS-) nipples not included.
Nominal Dimensions (inches)
Catalog
Number

Conduit
Size

Flex
Length

Weight
Pounds

Catalog
Number

Conduit
Size

Flex
Length

Weight
Pounds

10A–12

XFC-24

1/2

4

1-3/4

XFC-410

1

10

2-5/8

XFC-26

1/2

6

2

XFC-412

1

12

2-3/4

XFC-28

1/2

8

2-1/2

XFC-415

1

15

3

XFC-210

1/2

10

2-3/8

XFC-418

1

18

3-1/4

XFC-212

1/2

12

2-1/2

XFC-421

1

21

3-1/2

XFC-215

1/2

15

2-5/8

XFC-424

1

24

3-3/4

XFC-218

1/2

18

3

XFC-427

1

27

4-1/8

XFC-221

1/2

21

3-1/8

XFC-430

1

30

4-1/2

XFC-224

1/2

24

3-1/4

XFC-433

1

33

4-7/8

XFC-227

1/2

27

3-3/8

XFC-436

1

36

5-1/4

XFC-230

1/2

30

3-1/2

XFC-512

1-1/4

12

6-1/2

XFC-233

1/2

33

3-3/4

XFC-515

1/14

15

7

XFC-236

1/2

36

4

XFC-518

1-1/4

18

7-1/2

XFC-34

3/4

4

2

XFC-521

1-1/4

21

8-1/4

XFC-36

3/4

6

2-1/4

XFC-524

1-1/4

24

8-3/4

XFC-38

3/4

8

2-3/8

XFC-527

1-1/4

27

9-1/2

XFC-310

3/4

10

2-1/2

XFC-530

1-1/4

30

10-1/4

XFC-312

3/4

12

2-5/8

XFC-533

1-1/4

33

10-3/4

XFC-315

3/4

15

3

XFC-536

1-1/4

36

11-1/4

XFC-318

3/4

18

3-1/8

XFC-612

1-1/2

12

8-1/4

XFC-321

3/4

21

3-1/4

XFC-615

1-1/2

15

9

XFC-324

3/4

24

3-3/8

XFC-618

1-1/2

18

10

XFC-327

3/4

27

3-1/2

XFC-621

1-1/2

21

11

XFC-330

3/4

30

3-3/4

XFC-624

1-1/2

24

12

XFC-333

3/4

33

4

XFC-627

1-1/2

27

13

XFC-336

3/4

36

4-1/2

XFC-630

1-1/2

30

14

XFC-46

1

6

2-1/4

XFC-633

1-1/2

33

15

XFC-48

1

8

2-1/2

XFC-636

1-1/2

36

16

CSA Certified LR27991

Nominal Dimensions (inches)
Catalog
Number

Series

Conduit
Size

Classification*

A

B

C

Min. Radius
Bend

1/2

Class I & II

1-11/16

2-5/16

1-7/16

12

3/4

Group A, B, C, D, E, F & G

1-3/4

2-5/8

1-7/8

14

1

XFC

Class I & II
Group C, D, E, F & G

2

3

2-5/16

14

1-1/4

Class I & II

2-1/8

3-3/8

2-3/4

16

1-1/2

Group D, E, F & G

2-1/2

3-7/8

3-5/16

16

UL Listed E10493
Compliances
• NEC Class I, Groups A, B, C, D
Class II, Groups E, F, G
• UL Standard 886 - CSA Standard
C22.2 No. 30

304
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 305
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT FLEXIBLE COUPLINGS
*CLASS I, GROUPS A, B, C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Application: XFCU couplings are for use in Hazardous Atmospheres where a flexible
connection is required for motor and equipment installation where movement and vibration
are present. Also for difficult bends and connections.
Material: Brass and bronze end fittings. Bronze wire flexible braid covering over flexible bronze
core with insulating liner. INCLUDES ONE REMOVABLE ZINC CLEAR COATED NIPPLE ON
ONE SIDE AND ONE UNION FITTING ON THE OTHER SIDE.
Nominal Dimensions (inches)

CSA Certified LR27991

Conduit
Size

Flex
Length

Weight
Pounds

Catalog
Number

Conduit
Size

Flex
Length

XFCU-24

1/2

XFCU-26

1/2

Weight
Pounds

4

2

XFCU-410

1

10

3

6

2-1/4

XFCU-412

1

12

3-1/8

XFCU-28

1/2

8

2-1/2

XFCU-415

1

15

3-3/8

XFCU-210

1/2

10

2-5/8

XFCU-418

1

18

3-5/8

XFCU-212

1/2

12

2-3/4

XFCU-421

1

21

3-7/8

XFCU-215

1/2

15

3-1/8

XFCU-424

1

24

4-1/8

XFCU-218

1/2

18

3-1/4

XFCU-427

1

27

4-1/2

XFCU-221

1/2

21

3-3/8

XFCU-430

1

30

4-5/8

XFCU-224

1/2

24

3-1/2

XFCU-433

1

33

5-1/8

XFCU-227

1/2

27

3-5/8

XFCU-436

1

36

5-1/2

XFCU-230

1/2

30

3-3/4

XFCU-233

1/2

33

4

XFCU-236

1/2

36

4-1/4

XFCU-34

3/4

4

2-1/4

XFCU-36

3/4

6

2-1/2

XFCU-38

3/4

8

2-5/8

XFCU-310

3/4

10

2-3/4

XFCU-312

3/4

12

3-1/8

XFCU-315

3/4

15

3-1/4

XFCU-318

3/4

18

3-3/8

XFCU-321

3/4

21

3-1/2

XFCU-324

3/4

24

3-5/8

XFCU-327

3/4

27

3-3/4

XFCU-330

3/4

30

4

XFCU-333

3/4

33

4-1/4

XFCU-336

3/4

36

4-3/4

XFCU-46

1

6

2-5/8

XFCU-48

1

8

2-7/8

10A–13

Catalog
Number

UL Listed E10493
Nominal Dimensions (inches)
Catalog
Number
Series

Conduit
Size

Classification*

A

B

C

D

E

1/2

Class I & II

1-11/16

2-5/16

1-7/16

2-7/16

1-1/2

12

3/4

Group A,B,C,D,E,F & G

1-3/4

2-5/8

1-7/8

2-1/2

1-3/4

14

1

Group C,D,E,F & G

2

3

2-5/16

2-13/16

2

14

XFCU

Min. Radius
Bend

Class I & II

Compliances
• NEC Class I, Groups A, B, C, D
Class II, Groups E, F, G
• UL Standard 886 - CSA
Standard C22.2 No. 30

305
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 306
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF AND DUST-TIGHT
COMBINATION BREATHER/DRAIN
CLASS I, GROUPS C & D;
CLASS II, GROUPS F & G; NEMA 7 & NEMA 9

Stainless steel combination breather drain. Install in top of enclosures as
breather. Install in bottom of enclosure as drain.

A

Nominal Dimensions (inches)
Catalog Number

Thread

A

B

XDB2

1/2 NPT

1-5/8

7/8 hex

B

Compliances
• NEC Class I, Groups C, D Class II, Groups E, F, G - Class III

XDB2

• UL Standard 886 - CSA Standard C22.2 No. 30

10A–14

CSA Certified LR27991
UL Listed E10493

EXPLOSIONPROOF AND DUST-TIGHT
COMBINATION BREATHER/DRAIN
CLASS I, GROUPS A, B, C & D;
CLASS II, GROUPS E, F & G; NEMA 7 & NEMA 9
Nominal Dimensions (inches)
C

A

XDBH2

Catalog Number

Thread

A

B

C

XDBH2

1/2 NPT

2-7/16

7/8 HEX

1-1/4

Flow Rate:
.01 CFM air
.5 cc/minute water

Certifications
• Class I, Groups A, B, C and D Class II, Groups E, F & G - Class III
UL and CSA
UL Standard 886 - CSA Standard C22.2 No. 30

CSA Certified LR27991

• CENELEC EExd IIB DEMKO 00E.004127U

UL Listed E10493
306
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 307
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Fittings and Accessories
EXPLOSIONPROOF FLAME ARRESTOR FITTING
CLASS I, GROUPS B*, C & D NEMA 7

APPLICATION: Provides thru-wall connections of tubing systems for
electro/pneumatic and gas analysis devices installed within Adalet’s
explosion proof enclosures.
The flame arrestor fitting is designed to prevent flame propagation thru
tubing systems with minimum flow restrictions of control pressures.
Typical XFA2

MATERIAL: Stainless steel

Catalog Number

Description

Weight

XFA2

1/2” NPT

4 oz.

XFAX2

1/2” NPT

4 oz.

10A–15

Typical XFAX2

Exterior enclosure wall counter boring may be required to maintain 1/2”
enclosure wall thickness for ease of field connections.

XFA2
Approximate Control Restrictions

*XFAX2
Approximate Control Restrictions

* 0.5 PSI drop at 20 CFH airflow
* 1.3 PSI drop at 34 CFH airflow

1 PSI drop at 18 CFH airflow
5 PSI drop at 53 CFH airflow

*
*
*
*

UL and CSA Class I, Groups B, C & D
CENELEC EExd Group IIB
DEMKO 00E.0041270

NEC Class I, Groups C & D
UL Recognized Component
CSA Certified Component
CENELEC EExd Group IIB

CSA Certified LR27991
UL Recognized E10493
307

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 308
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Fittings and Accessories
SALI INSULATING BUSHINGS
(SUPERIOR ADALET LAMINATED INSULATION)
Specifications:
• 11,000 psi tensile
• 17,000 flexural
• 450v/mil dielectric
• Heat resistance - 150° C, continuous
• Moisture absorption - 1/2 of 1%
• Listed by Underwriters Laboratories
for your quality assurance.
• Sali bushings have been repeatedly
proved in a wide variety of
applications over a 25 year period.

Sali bushings are machined from paper
laminated phenolic material and comply with
NEMA-X phenolic material specifications.

TYPE PE-FEMALE-DEEP-THREADED
Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

PE-2

1/2

50

1-1/2

5/8

1-1/8

5/8

PE-3

3/4

50

2

13/16

1-5/16

5/8

I.D.

Nominal Dimensions (Inches)
O.D.
Height

10A–16

E10016
LISTED

Recommended for rigid conduit or
in combination with male type
PEM when maximum thread
engagement is required.

PE-4

1

50

3-1/2

1

1-5/8

25/32

PE-5

1-1/4

25

4-1/2

1-3/8

2

25/32

PE-6

1-1/2

25

5-1/2

1-5/8

2-1/4

25/32

PE-8

2

10

7-1/2

2

2-3/4

25/32

PE-10

2-1/2

5

12

2-7/16

3-1/4

1

PE-12

3

5

16

3

3-7/8

1-1/16

PE-14

3-1/2

5

19

3-1/2

4-3/8

1-1/16

PE-16

4

2

24

4

5

1-1/16

TYPE PES-FEMALE-SHALLOW-THREADED

E10016
LISTED

Designed for general use on rigid
conduit, connectors, and similar
installations where the additional
mechanical strength of the deep
type bushings is not needed.

Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

PES-2

1/2

50

1-1/2

5/8

1-1/8

1/2

PES-3

3/4

50

2

13/16

1-5/16

1/2

I.D.

Nominal Dimensions (Inches)
O.D.
Height

PES-4

1

50

3

1

1-5/8

5/8

PES-5

1-1/4

25

4

1-3/8

2

5/8

PES-6

1-1/2

25

4-1/2

1-5/8

2-1/4

5/8

PES-8

2

10

7

2

2-3/4

5/8

PES-10

21/2

5

11

2-7/16

3-1/4

13/16

PES-12

3

5

14

3

3-7/8

7/8

PES-14

3-1/2

5

16-1/2

3-1/2

4-3/8

7/8

PES-16

4

2

25

4

5

7/8

308
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 309
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Fittings and Accessories
TYPE PET-THREADLESS-FOR RIGID
CONDUIT-FEMALE-SET SCREW THREADLESS

For threadless rigid
conduit on all free conduit
terminals such as
terminating behind or
within switchboards,
switchgear, etc.

Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

PET-2

1/2

50

1-1/2

5/8

1-1/8

5/8

7/8

PET-3

3/4

50

2

13/16

1-5/16

5/8

1-1/16

I.D. 1

Nominal Dimensions (Inches)
O.D.
Height

I.D. 2

PET-4

1

50

3-1/2

1

1-5/8

25/32

1-11/32

PET-5

1-1/4

25

4-1/2

1-3/8

2

25/32

1-11/16

PET-6

1-1/2

25

5-1/2

1-5/8

2-1/4

25/32

1-15/16

PET-8

2

10

7-1/2

2

2-3/4

25/32

2-13/32

PET-10

2-1/2

5

12

2-7/16

3-1/4

1

2-29/32
3-17/32

PET-12

3

5

14

3

3-7/8

1-1/16

PET-14

3-1/2

5

17

3-1/2

4-3/8

1-1/16

4-1/32

PET-16

4

2

25

4

5

1-1/16

4-17/32

E10016
LISTED

E10016
LISTED

For use directly on thin
wall conduit.

Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

SPE-2

1/2

50

1-3/4

5/8

1-1/8

5/8

23/32

SPE-3

3/4

50

2-1/4

13/16

1-5/16

5/8

15/16

I.D. 1

Nominal Dimensions (Inches)
O.D.
Height

I.D. 2

SPE-4

1

50

3-3/4

1

1-5/8

25/32

1-3/16

SPE-5

1-1/4

25

5-1/4

1-3/8

2

25/32

1-17/32

SPE-6

1-1/2

25

6

1-5/8

2-1/4

25/32

1-25/32

SPE-8

2

10

8-1/4

2

2-3/4

25/32

2-7/32

For EMT sizes 2-1/2 thru 4” use type PET.

TYPE PEM

A high strength resilient male
bushing recommended to
protect wires passing through
steel cabinet walls, metal
partitions and similar
applications. For additional
strength it is recommended
this bushing be secured with
type PE deep threaded
female bushing.

Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

PEM-2

1/2

50

1

5/8

1-1/8

5/8

PEM-3

3/4

50

1-1/2

13/16

1-5/16

5/8
25/32

I.D.

Nominal Dimensions (Inches)
O.D.
Height

PEM-4

1

50

2-1/2

1

1-5/8

PEM-5

1-1/4

25

3

1-3/8

2

25/32

PEM-6

1-1/2

25

4

1-5/8

2-1/4

25/32

PEM-8

2

10

6

2

2-3/4

25/32

PEM-10

2-1/2

5

10

2-7/16

3-1/4

1-1/16

PEM-12

3

5

14

3

3-7/8

1-1/16

PEM-14

3-1/2

5

16-1/2

3-1/2

4-3/8

1-1/16

PEM-16

4

2

21

4

5

1-1/16

E10089
309

LISTED

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

10A–17

TYPE SPE-THREADLESS-FOR EMT-FEMALE-SET SCREW

15599 Sec.10 12/9/01 11:22 AM Page 310
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Fittings and Accessories

TYPE PEML WITH LOCKNUT

A high strength resilient male
bushing recommended to protect
wires passing through metal walls,
partitions and similar applications.
Furnished with metallic locknuts.

Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

PEML-2

1/2

50

2-1/2

5/8

1-1/8

5/8

PEML-3

3/4

50

3-1/2

13/16

1-5/16

5/8

I.D.

Nominal Dimensions (Inches)
O.D.
Height

PEML-4

1

50

6

1

1-5/8

25/32

PEML-5

1-1/4

25

6-1/2

1-3/8

2

25/32

PEML-6

1-1/2

25

9

1-5/8

2-1/4

25/32

PEML-8

2

10

11

2

2-3/4

25/32

PEML-10

2-1/2

5

30

2-7/16

3-1/4

1-1/16

PEML-12

3

5

34

3

3-7/8

1-1/16

PEML-14

3-1/2

5

39

3-1/2

4-3/8

1-1/16

PEML-16

4

2

56

4

5

1-1/16

10A–18

Poly PRECISION MOLDED INSULATING BUSHINGS

A rugged, high strength molded
bushing for general use on rigid
conduit connectors and similar
installations.
Listed by Underwriters Laboratories
Inc. for 105° C (221° F). Meets all
requirements of National Electrical
Code for insulating bushings.

Catalog
Number

Conduit
Size
(Inches)

Carton
Qty.

Wt. Per
Hundred
(Lbs.)

I.D.

PM-2

1/2

100

1

19/32

1-1/16

13/32

PM-3

3/4

100

1

25/32

1-5/16

13/32

PM-4

1

50

2

1

1-5/8

1/2

PM-5

1-1/4

25

3

1-5/16

2

1/2

PM-6

1-1/2

25

3

1-17/32

2-7/32

9/16
9/16

Nominal Dimensions (Inches)
O.D.
Height

PM-8

2

10

6

1-31/32

2-21/32

PM-10

2-1/2

5

11

2-5/16

3-5/16

5/8

PM-12

3

5

14

2-7/8

3-15/16

11/16

PM-14

3-1/2

5

22

3-5/16

4-7/16

11/16

PM-16

4

5

23

3-25/32

4-29/32

11/16

PM-20

5

2

40

4-13/16

6-3/16

31/32

PM-24

6

2

50

5-3/4

7-9/32

31/32

E25237
LISTED

310
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 311
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Fittings and Accessories

FIXTURE HANGERS
SWIVEL SELF ALIGNING OUTLET BOX COVERS

Types SA-342 and SA-42
Adalet self-aligning covers provide flexible suspension
assuring plumb alignment of the lighting fixture regardless of
ceiling structure or angle. Fixtures hung from these aligner
covers can be hit or bumped without damage that would be
caused if rigidly mounted.

Unit
Carton
Qty.

Catalog
Number

10A–19

Made of stamped steel, these Aligner Covers are equipped
with ball joint allowing the fixture to swing through an angle
of 20° in any direction of the perpendicular. The SA-342 has
two sets of supporting screw hole centers for 3-1/4” and 4”
octagonal outlet boxes and covers are spotted for 2-3/4”
mounting centers. Type SA-42 has two sets of supporting
screw holes for 4” square outlet boxes and covers are
spotted for 3-1/2” and 2-3/4” centers for 4” and 3-1/2”
octagonal boxes.

Approx
Wt.
Std. Pkg.

Standard
Package

*SA-342

25

100

41

SA-42

25

100

50

Ball tapped for 1/2” stem.

SA-342

SA-42

*

UL Listed E88804
311

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.10 12/9/01 11:22 AM Page 312
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Sky-Tie™ — Bus-Drop Cable Clamps
Supports...
Cable up to 1-1/8" diameter. Uniform “lap” design of each
clamp-half results in support along the entire quarter bend.

Anchors...
Cable for 90° angle transitions using a simple, two-piece
construction of interchangeable clamp-halves.

Loops...
Excess cable for convenient handling and out-of-the-way
storage, via the Sky-Tie™ SHD Duplex Converter. The SHD
reduces the need to cut cable when machines are moved to
new locations. The SHD converter simply fits between the
two halves of the Sky-Tie™ SH cable clamps.

Perfect For:
• Machine Tools
• Portable Tools
• Air Lines
• Other heavy-cable support applications.

10A–20

Sky-Tie™ Springs
Heavy-duty Sky-Tie™ Springs insure tautness of the cable,
while absorbing vibrations and shocks. Each spring slips into
the Sky-Tie™ clamp at its outside bend (or, if using the SHD
Duplex, the converter’s outside bend), and ties back to a
structural member. Three spring models with maximum load
capacities of 60, 70 and 160 pounds.
Sky-Tie™ Springs
Catalog
Number

Max.
Spring
Load

Carton
Approx.
Qty.
Wt.

Std. Pkg.
Approx.
Qty.
Wt.

SHS-50

60 lbs.

10

2.2

50

11

SHS-75

70 lbs.

10

2.7

50

14

SHS-1125 160 lbs.

10

11

10

11

SH
SHD

SHS

Sky-Tie™ Two-In-One Cable Clamps
Catalog
Number

Cable OD
(Inches)

Typical Multi-Conductor
Cable Size

Carton
Approx.
Qty.
Wt.

Std. Pkg.
Approx.
Qty.
Wt.

SH-50

1/2 to 3/4

14/4 thru 8/4

10

3.5

50

18.5

SH-75

3/4 to 1-1/8

8/4 thru 3/4 or (1) 500 MCM

10

7

50

36

SH-1125

1-1/8 to 1-11/16

Special Applications

5

10

25

50

Lugs prevent nuts
from turning.
Keyhole slots permit assembly on cable
without removal of bolts or threading of
cable through fitting.

Sky-Tie™ “Duplex” Component
Catalog
Number

Cable OD
(Inches)

Typical Multi-Conductor
Cable Size

Carton
Approx.
Qty.
Wt.

Std. Pkg.
Approx.
Qty.
Wt.

SHD-50

1/2 to 3/4

14/4 thru 3/4

10

3.25

50

17.25

SHD-75

3/4 to 1-1/2

8/4 thru 3/4 or (1) 500 MCM

10

7

50

36

312
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 195
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XIF/XIFC Explosionproof Internal Flanged Junction Boxes & Control Enclosures
XIF: Junction Boxes
XIFC: Control Enclosures
Optional NEMA 4. Add suffix “N4” to
catalog number.
Use layout sheet for drilling and tapping
specifications.
XIFC Certifications: (N4 Optional)
• Class I, Groups C & D
• Class II, Groups E, F & G
• Class III
• UL 1203 (Classified)

Inside Nominal
Catalog
Number

Mounting Lug

Dimensions

Overall Dimensions

CL to CL

Mounting

Shipping

Bolt

Weight,

W

L

D

A

B

C

E

F

Size

Pounds

4 5/16

3 1/4

5 1/2

5/16

5

XIFC 030303

XIF 030303

3 5/16

3 5/16

3 3/16

4 1/2

4 1/2

XIFC 030603

XIF 030603

3 1/4

5 3/4

3

4 1/2

7 1/16

4 1/4

3 1/4

8

5/16

6 1/2

XIFC 030703

XIF 030703

3 1/4

6 7/8

3

4 1/2

8 1/8

4 5/16

3 5/16

9

5/16

7 1/2

3

4 1/2

10 1/16

4 5/16

3 1/4

11

5/16

9 1/2

3

4 1/2

12

4 5/16

3 1/4

13

5/16

11

XIFC 030903

XIF 030903

XIFC 031103

XIF 031103

3 11/32 8 15/16
3 1/4

10 15/16

XIFC 031303

XIF 031303

3 1/4

12 13/16

3

4 1/2

14 1/16

4 5/16

3 1/4

15

5/16

11 1/2

XIFC 031503

XIF 031503

3 1/4

14 3/4

3 1/16

4 1/2

16

4 5/16

3 1/4

17

5/16

13

XIFC 031803

XIF 031803

3 1/4

17 3/4

3

4 1/2

19

4 1/4

3 1/4

20

5/16

16

XIFC 032403

XIF 032403

3 1/4

23 9/16

3

4 1/2

25 1/16

4 5/16

3 1/4

26

5/16

21

XIFC 033003

XIF 033003

3 1/4

29 1/2

3

4 9/16

31 1/16

4 5/16

3 1/4

32 1/8

5/16

28

XIFC 033603

XIF 033603

3 1/4

35 7/16

3

4 1/2

37

4 3/8

3 1/4

38 1/8

5/16

33

XIFC 040604

XIF 040604

4 1/8

5 7/8

4

5 3/8

7

5 5/16

4 3/8

8 1/4

5/16

8 1/2

XIFC 041204

XIF 041204

4 1/4

11 13/16

4

5 1/2

13 1/8

5 5/16

4 3/8

14 1/4

5/16

15 1/2

XIFC 060606

XIF 060606

5 1/2

5 1/2

6

7

7

7 3/8

5 1/2

8 1/2

3/8

14

XIFC 060608

XIF 060608

5 1/4

5 1/2

8

7

7

9 3/8

5 1/2

8 1/2

3/8

17 1/2

XIFC 061206

XIF 061206

5 1/4

11 1/8

6

7 1/4

13 1/2

7 5/8

5 1/2

15

3/8

28

XIF 061806

6

18

6

7 1/2

19 1/2

7 13/16

5 1/2

21 1/8

3/8

33

XIF 062406

6

24

6

7 1/2

25 1/2

7 3/4

5 1/2

27

3/8

59

XIF 063606

6

36

6

7 1/2

37 1/2

7 13/16

5 1/2

39

3/8

84

XIF 070704

6 7/8

6 7/8

4

5 5/16

6 5/8

9 1/8

3/8

13

XIF 071603

7

16

3 1/2

8 1/2

17 1/2

5 5/16

6 1/2

18 7/8

3/8

36

XIF 083206

8

32

5 7/8

9 1/2

33 1/2

7 7/8

7 1/2

35

3/8

87

XIFC 070704

7 15/16 7 15/16

5B–1

XIF Compliances:
• NEC Class I, Group D
• Class II, Groups E, F & G
• Class III
• UL Standard 886
• CSA Standard C22.2 No. 30
• For XIF consult factory for specific certifications.

Note: All dimensions are in inches and are nominal enclosure size only.
195
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 181
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XCE & XJF Explosionproof Enclosures
XCE EXPLOSIONPROOF CONTROL ENCLOSURES
XJF EXPLOSIONPROOF JUNCTION BOXES FLANGED
Design Options
• CENELEC flameproof optional – designate XCEX when
ordering. Includes external earthing assembly.
• Quad-lead bolt (quick thread bolt) option - designate XCEQ
when ordering. Not available with XCEX.
• NEMA 4 (WATERTIGHT)/IP66:
Features a nitrile O-Ring retained in the cover flange in a
machined groove. When ordering, add N4 to the catalog number.
*This option may affect certifications - consult factory.
• NEMA 6 (SUBMERSIBLE):
Consult factory.
• Cast-on mounting buttons, bosses and pads:
Per customer specifications.
• Captive cover bolts:
Consult factory.
• Hinges:
May be installed for removable or non-removable cover.
Left side standard, other locations optional.
• Windows:
Circular window sizes ranging from 1" to 8" diameter viewing area.
Rectangular window sizes ranging from 3" x 3" to 13" x 13"
viewing area.
• Stainless steel cover bolts. Consult factory for NEMA 4X
rating.
• Mounting Pans:
Available in galvanized steel, aluminum or phenolic.

Applications:
Adalet XCE series and XJF enclosures are used in the
installation of electrical/electronic components for control,
measurement or monitoring applications in hazardous
environments. XCE control enclosures can be modified for
installation of a variety of explosionproof operator devices,
viewing windows and accessories permitting the development
of customized enclosure systems.

• Sidewall auxiliary device installation or machining available on
XCE/XCEQ/XCEX series enclosures – Consult Factory.
• Factory machined metric sidewall threads approved on XCE and
XCEX series for Groups C & D only.
• The Adalet engineering department is available to assist in the
selection of custom explosionproof enclosures for your products.

Features
• Integral, cast-on mounting lugs, slotted for ease of field
installation.

5A–1

• Copper-free aluminum, lightweight and corrosion resistant.

Certifications

• Uniform wall thickness for ease of installation of control
devices, windows and conduit openings.

XCE Series Control Enclosures

• External flange provides maximum accessibility of
components mounted inside.

UL STANDARD 1203
CSA STANDARD C22.2 NO. 30

• Tumblast finish for quality appearance.

EN 5O 018 (XCEX)

XJF Junction Boxes
CSA STANDARD C22.2 NO. 30
UL STANDARD 886

• Premium high strength steel cover bolts, plated and coated
for maximum corrosion resistance (stainless steel optional).
• Enclosures certified drillable for conduit entrances in the
factory or the field.

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIB, (Specify XCEX)
ATEX Certifications available – Consult Factory.
NEMA 4, 7B*CD, 9EFG

• Internal grounding screw standard.
• Covers exceeding approximately 75 lbs. are provided with two
removable eye bolts for ease of handling.

Some sizes and option combinations may not be certified.
Consult Factory for specific certifications and file numbers.

• XCE/XCEQ/XCEX certified drillable for operators at the factory
or in the field.
• IP40 standard on XCEX without gasket.
ADALET Enclosure Systems • Designing Our Products Around Yours

181
SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 182
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XCE & XJF Explosionproof Enclosures
XCE/XJF
Catalog
Number

Inside Nominal
Dimensions
W
L
D

Usable
Inside
Depth

Mtg.
Bolt
Size

Apprx.
Shipping
Weight, lbs.

041604

4

16

4

4 3/4

7 1/4

19 1/4

6

12 1/8

6 3/4

3/8

25

060804

6

8

4

4 5/8

9 1/4

11 1/4

5 15/16

060805

6

8

5

5 5/8

9 1/4

11 1/4

6 15/16

4 1/2

9 1/8

3/8

21

4 1/2

9 1/8

3/8

23

060806

6

8

6

6 5/8

9 1/4

11 1/4

061105

6

11

5

5 7/8

9 1/4

14 1/4

7 15/16

4 1/2

9 1/8

3/8

25

7 3/16

7 1/2

9 1/8

3/8

24

061204

6

12

4

4 3/4

9 1/4

061206

6

12

6

6 3/4

9 1/4

15 1/4

6 1/16

8 1/2

9 1/8

3/8

24

15 1/4

8 1/16

8 1/2

9 1/8

3/8

29

061305

6

13

5

5 7/8

9 1/4

16 1/4

7 3/16

9 1/2

9 1/8

3/8

26

071004

7

10

4

4 3/4

10 3/8

13 3/8

6 3/16

6 1/2

9 3/4

3/8

27

071006

7

10

6 1/8

6 3/4

10 3/8

13 3/8

8 3/16

6 1/2

9 3/4

3/8

31

071805

7

18 1/4

5

5 3/4

10 3/8

21 5/8

7 3/16

14 1/2

9 3/4

3/8

55

080804

8

8

4

4 13/16

11 3/8

11 3/8

6 3/8

4 1/4

11

3/8

24

080806

8

8

6

6 13/16

11 3/8

11 3/8

8 3/8

4 1/4

11

3/8

28

080808

8

8

8

8 13/16

11 3/8

11 3/8

10 3/8

4 1/4

11

3/8

35

081004

8

10

4

4 3/4

11 3/8

13 3/8

6 1/4

6 1/2

10 3/4

3/8

30

081006

8

10

6

6 3/4

11 3/8

13 3/8

8 1/4

6 1/2

10 3/4

3/8

34

Overall Dimension
A
B
C

Mounting Lug
CL to CL
E
F

081008

8

10

8

8 3/4

11 3/8

13 3/8

10 1/4

6 1/2

10 3/4

3/8

39

081204

8

12

4

4 3/4

11 3/8

15 3/8

6 1/4

8 1/2

10 3/4

3/8

34

081206

8

12

6

6 3/4

11 3/8

15 3/8

8 1/4

8 1/2

10 3/4

3/8

42

081208

8

12

8

8 3/4

11 3/8

15 3/8

10 1/4

8 1/2

10 3/4

3/8

48

091105

9

11

5

5 3/4

12 3/8

14 3/8

7 5/16

7 1/2

12

3/8

41

101004

10

10

4

4 3/4

13 3/8

13 3/8

6 5/16

6 1/2

13

3/8

34

• To indicate Quad-Lead bolt
option, add suffix "Q" after XCE.
(Not available on XCEX models.)

101006

10

10

6

6 3/4

13 3/8

13 3/8

8 5/16

6 1/2

13

3/8

44

101008

10

10

8

8 3/4

13 3/8

13 3/8

10 5/16

6 1/2

13

3/8

50

• Operators, windows and hinges
are ordered separately.

101206

10

12

6 1/4

7 1/4

13 3/8

15 3/8

8 7/8

8 1/2

13 1/4

3/8

46

101404

10

14

4

4 3/4

13 3/8

17 3/8

6 7/16

10 5/8

13 1/4

3/8

42

• To indicate EEx d approval
specify XCEX.

101406

10

14

6

6 3/4

13 3/8

17 3/8

8 7/16

10 5/8

13

3/8

49

101408

10

14

8

8 3/4

13 3/8

17 3/8

10 1/2

10 5/8

13

3/8

57

101410

10

14

8

10 13/16 13 3/8

17 3/8

12 7/16

10 5/8

13

3/8

70

121204

12

12

4

5

16 1/4

16 1/4

6 15/16

8 5/8

15 3/4

1/2

60

121206

12

12

6

7

16 1/4

16 1/4

8 15/16

8 5/8

15 3/4

1/2

68

121208

12

12

8

9

16 1/4

16 1/4

10 15/16

8 5/8

15 3/4

1/2

80

121804

12

18

4

4 3/4

16 1/4

22 1/4

6 3/4

14 1/8

15 3/4

1/2

85

121806

12

18

6

6 3/4

16 1/4

22 1/4

8 3/4

14 1/8

15 3/4

1/2

93

121808

12

18

8

8 3/4

16 1/4

22 1/4

10 3/4

14 1/8

15 3/4

1/2

101

122005

12

20

5

5 3/4

16 1/4

24 1/4

8 1/8

14 3/8

15 3/4

1/2

104

122404

12

24

4

4 15/16

16 1/4

28 1/4

7 1/4

18 3/8

15 3/4

1/2

116

122406

12

24

6

6 15/16

16 1/4

28 1/4

9 1/4

18 3/8

15 3/4

1/2

127

• To indicate NEMA 4/IP66 option,
add suffix “N4” after size
(catalog number).

5A–2

Note: All dimensions are in inches
and are nominal enclosure size
only. Inside nominal dimensions
are at flange. Consult factory for
exact dimensions.

*

*Approval Pending – Consult Factory.

182
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 183
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XCE & XJF Explosionproof Enclosures

*
*
*
*

*
*

Inside Nominal
Dimensions
W
L
D

Usable
Inside
Depth

Mounting Lug
CL to CL
E
F

122408

12

24

8

8 15/16

16 1/4

28 1/4

11 1/4

18 3/8

122410

12

24

10 10 15/16 16 1/4

28 1/4

13 1/4

18 3/8

15 3/4

1/2

154

123006

12

30

6

6 11/16

16 3/4

34 1/4

9 5/8

23

15 3/4

1/2

180

123604

12

36

4

4 15/16

16 1/4

40 1/4

7 11/16

29

15 3/4

1/2

192

123606

12

36

6

6 15/16

16 1/4

40 1/4

9 11/16

29

15 3/4

1/2

212

123608

12

36

8

8 15/16

16 1/4

40 1/4

11 11/16

29

15 3/4

1/2

232

124608

12

46

8

8 15/16

16 1/4

50 1/4

11 11/16

39

15 3/4

5/8

280

141404

14

14

4

5

18 1/4

18 1/4

7 1/8

9 3/4

17 3/4

1/2

91

141406

14

14

6

7

18 1/4

18 1/4

9 1/4

9 3/4

17 3/4

1/2

97

141408

14

14

8

9

18 1/4

18 1/4

11 1/8

9 3/4

17 3/4

1/2

103

142210

14

22

10

11 1/4

18 1/4

26 1/4

13 5/8

16 1/2

17 3/4

1/2

181

142213

14

22

10

13

18 1/4

26 1/4

15 1/8

16 1/2

17 3/4

1/2

235

142806

14

28

6

7 13/16

18 1/4

32 1/4

9 9/16

22 1/2

17 3/4

1/2

120

161604

16

16

4

6 5/8

20 7/8

20 7/8

7 15/16

11

19 3/4

5/8

114

161606

16

16

6

7 5/8

20 7/8

20 7/8

9 15/16

11

19 3/4

5/8

135

161608

16

16

8

9 5/8

20 7/8

20 7/8

11 15/16

11

19 3/4

5/8

156

162406

16

24

6

7 13/16

20 7/8

28 7/8

10 3/8

18 3/8

19 3/4

5/8

190

162408

16

24

8

9 13/16

20 7/8

28 7/8

12 3/8

18 5/8

19 3/4

5/8

209

162410

16

24

10 11 13/16 20 7/8

28 7/8

14 3/8

18 3/8

19 3/4

5/8

225

162806

16

28

6

6 13/16

20 1/2

32 11/16

9 1/2

22 1/2

19 3/4

5/8

200

163406

16

34

6

6 15/16

20 1/2

38 1/2

9 1/2

27

19 3/4

5/8

260

163010

16

30

10

11 1/8

20 1/2

34 1/2

13 7/8

27

19 3/4

5/8

320

164610

16

46

10 11 13/16 20 7/8

50 7/8

14 9/16

39

19 3/4

5/8

390

181804

18

18

4

5 13/16

22 7/8

22 7/8

8 1/2

13

21 3/4

5/8

154

181806

18

18

6

7 13/16

22 7/8

22 7/8

10 1/2

13

21 3/4

5/8

177

181808

18

18

8

9 13/16

22 7/8

22 7/8

12 1/2

13

21 3/4

5/8

200

182406

18

24

6

7 7/16

22 7/8

28 7/8

10 13/16

18 3/8

21 3/4

5/8

226

182408

18

24

8

9 7/16

22 7/8

28 7/8

12 13/16

18 3/8

21 3/4

5/8

239

182410

18

24

10

11 7/16

22 7/8

28 7/8

14 13/16

18 3/8

21 3/4

5/8

260

183008

18

30

8

9 3/8

22 7/8

34 7/8

12 13/16

23

21 3/4

5/8

293

183608

18

36

8

9 3/8

22 7/8

40 7/8

12 7/8

29

21 3/4

5/8

318

183610

18

36

10

11 3/8

22 7/8

40 7/8

14 7/8

29

21 3/4

5/8

340

203606

20

36

6

7 1/8

24 7/8

40 7/8

10 7/8

29

24

5/8

340

203612

20

36

6

12

25 5/8

41 5/8

15

29

24

5/8

415

204806

20

48

6

7 1/8

24 7/8

52 7/8

10 7/8

41

24

5/8

430

204812

20

48

6

12

25 5/8

53 5/8

15

41

24

5/8

515

242408

24

24

8

9 7/16

28 7/8

28 7/8

12 7/16

18 3/8

28

5/8

302

242410

24

24

10

11 7/16

28 7/8

28 7/8

14 7/16

18 3/8

28

5/8

330

243008

24

30

8

9 1/4

28 7/8

34 7/8

12 15/16

23

28

5/8

356

243608

24

36

8

9 1/4

28 7/8

40 7/8

12 7/16

29

28

5/8

408

243610

24

36

10

11 1/4

28 7/8

40 7/8

14 7/8

29

28

5/8

433

243612

24

36

10

12

28 7/8

40 7/8

16 1/2

29

28

5/8

545

323612

32

36

6

12

37 3/4

41 3/4

15 1/2

29

36 1/8

5/8

691

Overall Dimension
A
B
C

15 3/4

Mtg.
Bolt
Size

Apprx.
Shipping
Weight, lbs.

1/2

140

• To indicate Quad-Lead bolt
option, add suffix "Q" after XCE.
(Not available on XCEX models.)
• Operators, windows and hinges
are ordered separately.
• To indicate EEx d approval
specify XCEX.
• To indicate NEMA 4/IP66 option,
add suffix “N4” after size
(catalog number).
Note: All dimensions are in inches
and are nominal enclosure size
only. Inside nominal dimensions
are at flange. Consult factory for
exact dimensions.
*Approval Pending – Consult Factory.

183
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

5A–3

*
*

XCE/XJF
Catalog
Number

15599 Sec.5 A 12/11/01 6:06 PM Page 184
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Bolt-On Mounting Lugs for XCE & XJF Enclosures
Adjust To Irregular Mounting Surfaces
Without Damaging Enclosures

Adalet Bolt-On Mounting Lugs for XCE and XJF Enclosures
are bi-directional, permitting either vertical or horizontal
mounting orientation. The ductile aluminum alloy lugs adapt
to irregular surfaces so lug bolts can be tightened without
damaging the enclosure.

5A–4
184
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 185
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Bolt-On Mounting Lugs
Catalog
Number

Mounting Dimensions
Optional Mounting
Standard Mounting
J
K
L
M

Mtg. Lug
Size
N

Mtg. Lug
Thickness
T

Catalog
Number

Mounting Dimensions
Optional Mounting
Standard Mounting
J
K
L
M

Mtg. Lug
Size
N

Mtg. Lug
Thickness
T

X

X

7 7/8

4

3/8

1/4

XCE124608M

7

49

15

41

1/2

3/8

XCE060805M

X

X

7 7/8

4

3/8

1/4

XCE141404M

9

17

17

9

1/2

3/8

XCE060806M

X

X

7 7/8

4

3/8

1/4

XCE141406M

9

17

17

9

1/2

3/8

XCE061105M

X

X

7 7/8

9

3/8

1/4

XCE141408M

9

17

17

9

1/2

3/8

XCE061204M

X

X

7 7/8

10

3/8

1/4

XCE142806M

9

31

17

23

1/2

3/8

XCE061206M

X

X

7 7/8

10

3/8

1/4

XCE161604M

11

19

19

10 15/16

1/2

3/8

XCE061305M

X

X

7 7/8

11

3/8

1/4

XCE161606M

11

19

19

10 15/16

1/2

3/8

XCE071004M

X

X

8 7/8

8

3/8

1/4

XCE161608M

11

19

19

10 15/16

1/2

3/8

XCE071006M

X

X

8 7/8

8

3/8

1/4

XCE162406M

11 3/8

27 1/4

19 3/8

19 3/8

1/2

3/8

XCE071805M

X

X

8 7/8

16

3/8

1/4

XCE162408M

11 3/8

27 1/4

19 3/8

19 3/8

1/2

3/8

XCE080804M

X

X

9 7/8

6

3/8

1/4

XCE162410M

11 3/8

27 1/4

19 3/8

19 3/8

1/2

3/8

XCE080806M

X

X

9 7/8

6

3/8

1/4

XCE162806M

11 3/8

31 3/8

19 3/8

23

1/2

3/8

XCE080808M

X

X

9 7/8

6

3/8

1/4

XCE163406M

11 3/8

37 3/8

19 3/8

29 3/8

1/2

3/8

XCE081004M

X

X

9 7/8

8

3/8

1/4

XCE164610M

11 3/8

49 3/8

19 3/8

41 3/8

1/2

3/8

XCE081006M

X

X

9 7/8

8

3/8

1/4

XCE181804M

13 3/8

21 3/8

21 3/8

13 3/8

1/2

3/8

XCE081008M

X

X

9 7/8

8

3/8

1/4

XCE181806M

13 3/8

21 3/8

21 3/8

13 3/8

1/2

3/8

XCE081204M

3 13 /16

14 3/8

10 3/8

7 13/16

1/2

3/8

XCE181808M

13 3/8

21 3/8

21 3/8

13 3/8

1/2

3/8

XCE081206M

3 13 /16

14 3/8

10 3/8

7 13/16

1/2

3/8

XCE182406M

13

27

21

19

1/2

3/8

XCE081208M

3 13 /16

14 3/8

10 3/8

7 13/16

1/2

3/8

XCE182408M

13

27

21

19

1/2

3/8

XCE091105M

4 13/16

13 3/8

11 3/8

9

1/2

3/8

XCE182410M

13

27

21 1/4

19

1/2

3/8

XCE101004M

5

13

13

5

1/2

3/8

XCE183008M

13

31

21

25

1/2

3/8

XCE101006M

5

13

13

5

1/2

3/8

XCE183608M

13 1/4

39 1/2

21

31 1/2

1/2

3/8

XCE101008M

5

13

13

5

1/2

3/8

XCE183610M

13 1/4

39 1/2

21 1/4

31 1/2

1/2

3/8

XCE101206M

5

15

13

6

1/2

3/8

XCE203606M

15 3/4

39 3/4

23 3/4

31 3/4

1/2

3/8

XCE101404M

5

17

13

9

1/2

3/8

XCE204806M

15 3/4

51 3/4

23 3/4

43 3/4

1/2

3/8

XCE101406M

5

17

13

9

1/2

3/8

XCE242408M

19 1/2

27 1/2

27 1/2

19 1/2

1/2

3/8

XCE101408M

5

17

13

9

1/2

3/8

XCE242410M

19 1/2

27 1/2

27 1/2

19 1/2

1/2

3/8

XCE101410M

5

17

13

9

1/2

3/8

XCE243008M

19 9/16

33 9/16

27 9/16

25 9/16

1/2

3/8

XCE121204M

7

15

15

7

1/2

3/8

XCE243608M

19 9/16

39 9/16

27 9/16

31 9/16

1/2

3/8

XCE121206M

7

15

15

7

1/2

3/8

XCE243610M

19 9/16

39 9/16

27 9/16

31 9/16

1/2

3/8

XCE121208M

7

15

15

7

1/2

3/8

XCE121804M

7

20 7/8

15

12 7/8

1/2

3/8

XCE121806M

7

20 7/8

15

12 7/8

1/2

3/8

XCE121808M

7

20 7/8

15

12 7/8

1/2

3/8

XCE122005M

7

22 7/8

15

14 7/8

1/2

3/8

XCE122404M

7

26 7/8

15

18 7/8

1/2

3/8

XCE122406M

7

26 7/8

15

18 7/8

1/2

3/8

XCE122408M

7

26 7/8

15

18 7/8

1/2

3/8

XCE122410M

7

26 7/8

15

18 7/8

1/2

3/8

XCE123006M

7

33

15

24 7/8

1/2

3/8

XCE123604M

7

39

15

31

1/2

3/8

XCE123606M

7

39

15

31

1/2

3/8

XCE123608M

7

39

15

31

1/2

3/8

5A–5

XCE060804M

185
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 186
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XCE Series Recommended Spacing For Operators In Covers

Catalog
Number

Standard Operators
Maximum Maximum
Maximum Number
Number Recommended
Number
Operator
Operators
Spacing
Operators
Rows
Per Row
CL to CL

Miniature Operators
Maximum Maximum
Maximum Number
Number
Number Operator
Operators
Operators
Rows
Per Row

Recommended
Spacing
CL to CL

Cover
Wall
Thickness
(Inches)

XCE041604

5

5

1

2 1/2

13

13

1

1

1/2

XCE060804

2

2

1

2 1/2

8

4

2

1

1/2

XCE060805

2

2

1

2 1/2

8

4

2

1

1/2

XCE060806

2

2

1

2 1/2

8

4

2

1

1/2

XCE061105

3

3

1

2 1/2

14

7

2

1

1/2

XCE061204

4

4

1

2 1/2

16

8

2

1

5/8

XCE061206

4

4

1

2 1/2

16

8

2

1

5/8

XCE061305

4

4

1

2 1-2

18

9

2

1

1/2

XCE071004

6

3

2

2 1/2

18

6

3

1

5/8

XCE071006

6

3

2

2 1/2

18

6

3

1

5/8

XCE071805

12

6

2

2 1/2

45

15

3

1

5/8

XCE080804

4

2

2

2 1/2

16

4

4

1

11/16

XCE080806

4

2

2

2 1/2

16

4

4

1

11/16

XCE080808

4

2

2

2 1/2

16

4

4

1

11/16

XCE081004

6

3

2

2 1/2

24

6

4

1

11/16

XCE081006

6

3

2

2 1/2

24

6

4

1

11/16

XCE081008

6

3

2

2 1/2

24

6

4

1

11/16

XCE081204

8

4

2

2 1/2

32

8

4

1

11/16

XCE081206

8

4

2

2 1/2

32

8

4

1

11/16

XCE081208

8

4

2

2 1/2

32

8

4

1

11/16

XCE091105

6

3

2

2 1/2

35

7

5

1

11/16

XCE101004

9

3

3

2 1/2

36

6

6

1

11/16

XCE101006

9

3

3

2 1/2

36

6

6

1

11/16

5A–6

XCE101008

9

3

3

2 1/2

36

6

6

1

11/16

XCE101206

12

4

3

2 1/2

48

8

6

1

3/4

XCE101404

12

4

3

2 1/2

60

10

6

1

3/4

XCE101406

12

4

3

2 1/2

60

10

6

1

3/4

XCE101408

12

4

3

2 1/2

60

10

6

1

3/4

XCE101410

12

4

3

2 1/2

60

10

6

1

3/4

XCE121204

9

3

3

3

64

8

8

1

7/8

XCE121206

9

3

3

3

64

8

8

1

7/8

XCE121208

9

3

3

3

64

8

8

1

7/8

XCE121804

15

5

3

3

92

14

8

1

15/16

XCE121806

15

5

3

3

92

14

8

1

15/16

XCE121808

15

5

3

3

92

14

8

1

15/16

XCE122005

18

6

3

3

128

16

8

1

1 1/8

XCE122404

21

7

3

3

150

20

8

1

1 1/8

XCE122406

21

7

3

3

150

20

8

1

1 1/8

XCE122408

21

7

3

3

150

20

8

1

1 1/8

Note: Closer spacing other than 21/2 & 3 inches available – Consult factory for special designs.

186
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 187
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Catalog
Number

Standard Operators
Maximum Maximum
Maximum Number
Number Recommended
Number
Operator
Operators
Spacing
Operators
Rows
Per Row
CL to CL
7

3

3

Miniature Operators
Maximum Maximum
Maximum Number
Number
Number Operator
Operators
Operators
Rows
Per Row
150

20

Recommended
Spacing
CL to CL

Cover
Wall
Thickness
(Inches)

1

1 1/8

XCE122410

21

8

XCE123006

27

9

3

3

150

26

8

1

1 3/8

XCE123604

33

11

3

3

150

32

8

1

1 3/16

XCE123606

33

11

3

3

150

32

8

1

1 3/16

XCE123608

33

11

3

3

150

32

8

1

1 3/16

XCE124608

42

14

3

3

150

41

8

1

1 1/4

XCE141404

16

4

4

3

100

10

10

1

7/8

XCE141406

16

4

4

3

100

10

10

1

7/8

XCE141408

16

4

4

3

100

10

10

1

7/8

XCE142210

24

6

4

3

100

18

10

1

1 1/8

XCE142213

24

6

4

3

100

18

10

1

1 1/8

XCE142806

32

8

4

3

150

24

10

1

1 1/8

XCE161604

16

4

4

3 1/2

121

11

11

1

7/8

XCE161606

16

4

4

3 1/2

121

11

11

1

7/8

XCE161608

16

4

4

3 1/2

121

11

11

1

7/8

XCE162406

24

6

4

3 1/2

150

19

11

1

7/8

XCE162408

24

6

4

3 1/2

150

19

11

1

7/8

XCE162410

24

6

4

3 1/2

150

19

11

1

7/8

XCE162806

28

7

4

3 1/2

150

24

11

1

1 1/4

XCE163010

32

8

4

3 1/2

150

26

12

1

1 1/4

XCE163406

32

8

4

3 1/2

150

30

11

1

1 1/4

XCE164610

48

12

4

3 1/2

150

41

11

1

1

XCE181804

16

4

4

3 1/2

150

13

13

1

1

XCE181806

16

4

4

3 1/2

150

13

13

1

1

XCE181808

16

4

4

3 1/2

150

13

13

1

1

XCE182406

24

6

4

3 1/2

150

19

13

1

1 1/2

XCE182408

24

6

4

3 1/2

150

19

13

1

1 1/2

XCE182410

24

6

4

3 1/2

150

19

13

1

1 1/2

XCE183008

32

8

4

3 1/2

150

25

13

1

1 1/2

XCE183608

36

9

4

3 1/2

150

31

13

1

1 7/8

XCE183610

36

9

4

3 1/2

150

31

13

1

1 7/8

XCE203606

45

9

5

3 1/2

150

31

15

1

1 7/8

XCE203612

45

9

5

3 1/2

150

31

15

1

1 3/8

XCE204806

65

13

5

3 1/2

150

43

15

1

1 7/8

XCE204812

65

13

5

3 1/2

150

43

15

1

1 3/8

XCE242408

36

6

6

3 1/2

150

19

19

1

1 1/2

XCE242410

36

6

6

3 1/2

150

19

19

1

1 1/2

XCE243008

42

7

6

3 1/2

150

25

19

1

1 7/8

XCE243608

54

9

6

3 1/2

150

31

19

1

1 7/8

XCE243610

54

9

6

3 1/2

150

31

19

1

1 7/8

XCE243612

54

9

6

3 1/2

150

31

19

1

1 3/8

XCE323612

72

9

8

3 1/2

150

31

27

1

1 3/8

5A–7

XCE Series Recommended Spacing For Operators In Covers

Note: Closer spacing other than 3 & 31/2 inches available – Consult factory for special designs.

187
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 188
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XCE & XJF Explosionproof Enclosures

5A–8
188
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 189
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Conduit Drilling and Tapping Guidelines
When drilling & tapping enclosures for conduit, proper installation requires compliance with the following:
1. Must be tapped with at least 5 full NPT threads (XCEX requires six NPT threads) in enclosure back
or sides only; min. 1/2" conduit size.
2. Tapping depth of NPT holes must be plus 1/2 turn min. to plus 1-1/2 turns max. past standard NPT plug gage notch.
3. Inner end of conduit openings shall be smooth and well-rounded.

TABLE I
Thread Size Of

Minimum wall thickness at conduit entrance excluding XCEX

Conduit, Inches (NPT)

Explosionproof

1/2 - 3/4

3/8 inch

Dust Ignition Proof / Weather Proof
1/4 inch

1-2

7/16 inch

5/16 inch

2 1/2 - 5

5/8 inch

7/16 inch

TABLE II
Conduit size, inches (NPT)

1/2

3/4

1

1 1/4

1 1/2

2

2 1/2

3

3 1/2

4

5

Minimum Distance from conduit CL
to inside corner or back of box

1 5/16

1 7/16

1 9/16

1 3/4

1 7/8

2 1/8

2 3/8

2 11/16

2 15/16

3 1/4

3 7/8

Approximate diameter of union

1 7/8

1 7/8

2 1/16

2 7/8

3 1/4

3 7/8

4 7/8

5 1/2

6

6 1/2

7 1/2

1

3/4

1/2
1 1/2

TABLE III
Minimum spacing between conduit centers thru sidewalls only (inches)
(Double all distances in table for holes located in backwall)
5

4

3 1/2

3

2 1/2

2

1 1/2

1 1/4

1/2

4 1/2

3 5/8

3/4

4 3/4

3 3/4

3 3/8

3

2 5/8

3 1/2

3 1/8

2 3/4

2 3/8

2

1 7/8

1 3/4

1 5/8

2 1/2

2 1/8

2

1 7/8

1 3/4

1

4 7/8

4

3 5/8

3 1/4

3

2 5/8

2 3/8

2 1/4

2

1 1/4

5 1/8

4 1/8

3 7/8

3 1/2

3 1/8

2 7/8

2 1/2

2 3/8

1 1/2

5 1/2

4 1/4

2

5 3/4

4 5/8

4

3 5/8

3 1/4

3

2 5/8

4 1/4

3 7/8

3 5/8

3 1/4

2 1/2

6

4 7/8

4 5/8

4 1/4

3 7/8

3

6 1/4

5 3/8

5

4 5/8

3 1/2
4

6 1/2

5 5/8

5 1/4

6 3/4

5 7/8

5

7 1/4

5A–9

Size

This information is compiled from data which we believe is reliable and is given in good faith. Since the methods of application
and conditions under which our products are used are beyond our control, we are not able to guarantee the application and/or
use of same. The user assumes all risks and liability in connection with the application and use of our products.
Note: All dimensions are in inches.
Metric threads available from factory for Group C & D applications only – Consult Factory.
The Adalet engineering department is available to assist in designing custom explosionproof enclosures for your products.
189
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 190
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Conduit & Auxiliary Device Drilling and Tapping Guidelines
SPACING FOR AUXILIARY DEVICES INSTALLED
IN BOX WALLS OF CONTROL PANEL ENCLOSURES
USED IN HAZARDOUS LOCATIONS.
When using an Auxiliary Device in the box wall of an enclosure used in hazardous locations,
proper installation requires compliance with the following:
1. A minimum of (5) thread engagement, class 2 fit, required for group C & D applications.
A minimum of (7) thread engagement, class 2 fit, required for group B applications.
2. Table I shows minimum box wall thickness for Auxiliary Device threads.

TABLE I
REQUIRED MINIMUM BOX WALL THICKNESS
Thread Size (In.)
1/2 – 3/4 NPSM
1 NPSM

Group C & D Applications
min. (5) thread engagement

Group B Applications
min. (7) thread engagement

Typical Auxiliary Devices
XBO, XHPB, XHSS, Standard Operators

(14 PITCH)

(11 1/2 PITCH)

3/8 NPSM

(18 PITCH)

3/8 – 16 UNC

3/8 Inch

1/2 Inch

7/16 Inch

5/8 Inch

XCBH Large Handle Assembly

9/32 Inch

13/32 Inch

XCBH Small Handle Assembly

5/16 Inch

7/16 Inch

XMOB, XMOSS, Mini Operators

3. If Auxiliary Device contains undercut in engaging threaded section, the minimum wall thickness shown in Table I must increase
to maintain the minimum required thread engagement. (Fig. A)
4. Table II provides the minimum distance an Auxiliary Device center can be placed from inside corner or back of box.
SEE NOTE 3

TABLE II
AUXILIARY DEVICE THREAD SIZE (In.)

3/8-16
UNC

3/8
NPSM

1/2
NPSM

3/4
NPSM

1
NPSM

Minimum distance from Auxiliary Device
CL to inside corner of back of box.

1-1/2

1-5/8

1-3/4

1-7/8

2

Auxiliary
Device

COUNTERSINK/
CHAMFER DEPTH
WALL Y
THICKNESS

5. Table III shows minimum spacing between conduit and Auxiliary Device entrances.

FIG. A

TABLE III
Minimum space between centers of conduits and auxiliary devices in box wall. (Inches)
Conduit Thread Size (NPT)
5

4

3-1/2

3

2-1/2

2

1-1/2

1-1/4

1

3/4

1/2

3/8

4-1/2

3-5/8

3-3/8

3

2-5/8

2-3/8

2

1-7/8

1-3/4

1-5/8

1-1/2

1/2

4-5/8

3-3/4

3-1/2

3-1/8

2-3/4

2-1/2

2-1/4

2-1/8

2

1-7/8

1-3/4

3/4

4-3/4

4

3-5/8

3-1/4

2-7/8

2-5/8

2-3/8

2-1/4

2-1/8

2

1-7/8

1

5

4-1/4

3-7/8

3-1/2

3

2-3/4

2-1/2

2-3/8

2-1/4

2-1/8

2

5A–10

Aux. Device
Thread Size

TABLE IV

6. Table IV shows minimum spacing
between auxiliary device entrances.
NOTE: Increase distance between
devices as required to maintain
minimum through air spacing of
contacts required by electrical
codes.
7. Double all distances in Table III and
IV for holes located in back wall.

Minimum spacing between Auxiliary Device of
varying thread sizes (Inches)
3/8

1/2

3/4

1

3/8

1-1/2

1-1/2

1-1/2

2-1/2

1/2

1-1/2

2

2

2-1/2

3/4

1-1/2

2

2

3

1

2-1/2

2-1/2

3

3-1/2

Consult factory for layout data sheets.

190
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 191
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XCE and XJF Mounting Pans and Hinges

Catalog
Number
(Steel)
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM
XSM

0416
0608
0611
0612
0613
0710
0718
0808
0810
0812
0911
1010
1012
1014
1212
1218
1220
1224
1230
1236
1246
1414
1422
1428
1616
1624
1628
1630
1634
1646
1818
1824
1830
1836
2036
2048
2424
2430
2436
3236

HINGES

Catalog
Number
(Aluminum)

Catalog
Number
(Phenolic)

Pan
Dimensions Nominal
Width
Length

XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA
XSA

XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB
XSB

3
5
5
5
5
6
6

0416
0608
0611
0612
0613
0710
0718
0808
0810
0812
0911
1010
1012
1014
1212
1218
1220
1224
1230
1236
1246
1414
1422
1428
1616
1624
1628
1630
1634
1646
1818
1824
1830
1836
2036
2048
2424
2430
2436
3236

0416
0608
0611
0612
0613
0710
0718
0808
0810
0812
0911
1010
1012
1014
1212
1218
1220
1224
1230
1236
1246
1414
1422
1428
1616
1624
1628
1630
1634
1646
1818
1824
1830
1836
2036
2048
2424
2430
2436
3236

1/4
1/8
1/8
1/8
1/8
1/8
1/8
7
7
6 7/8
8
8 7/8
10 7/8
8 7/8
10 7/8
10 1/2
11
11
10 3/4
10 3/4
10 3/4
12 7/8
12 7/8
12 7/8
14 3/4
14 1/2
26 1/2
14 1/2
32 1/2
14 1/2
16 3/4
16 1/2
16 1/2
16 1/2
34 1/2
46 1/2
22
22
34
29

Enclosure Size
Reference
Inside width x length

15 1/4
7 1/8
10 1/8
11 1/8
12 1/8
9 1/8
17 3/8
7
9 1/8
10 7/8
10
8 7/8
8 7/8
12 7/8
10 7/8
16 1/2
19
23
28 3/4
34 3/4
44 3/4
12 7/8
20 7/8
26 7/8
14 3/4
22 1/2
14 1/2
28 1/2
14 1/2
44 1/2
16 3/4
22 1/2
28 1/2
34 1/2
18 1/2
18 1/2
22
28
22
33

4
6
6
6
6
7
7
8
8
8
9
10
10
10
12
12
12
12
12
12
12
14
14
14
16
16
16
16
16
16
18
18
18
18
20
20
24
24
24
32

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

16
8
11
12
13
10
18
8
10
12
11
10
12
14
12
18
20
24
30
36
46
14
22
28
16
24
28
30
34
46
18
24
30
36
36
48
24
30
36
36

Weight
Each (pounds)
(Steel)

Hinges
Catalog
Number

1 1/2
1
1 1/2
1 3/4
2
1 1/4
2 1/2
1 1/4
1 1/2
2 1/4
2 1/2
2 1/2
3
3 1/2
3 3/4
5 1/2
6 1/2
8
9 3/4
11 3/4
15
5
8
10 3/4
6 3/4
10 1/4
12
12 1/2
14 3/4
20 1/4
8 3/4
11 1/2
14 3/4
18
20
27
15 1/4
19 1/4
23 1/2
28 3/4

XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2
XHB-2

4
6
6
6
6
7
7
8
8
8

XHB-2
XHB-2
XHB-2
XHB-2
XHC-2
XHC-2
XHC-2
XHC-2
XHC-2
XHD-3

9
10
10
10
12
12
12
12
12
12

x
x
x
x
x
x
x
x
x
x

11
10
12
14
12
18
20
24
30
36

XHD-4
XHC-2
XHF-2
XHF-2
XHD-2
XHF-2
XHF-2
XHF-2
XHD-3
XHF-4
XHF-2
XHF-2
XHF-2
XHF-3
XHF-3
XHF-4
XHF-2
XHF-2
XHF-3
XHF-3

12
14
14
14
16
16
16
16
16
16
18
18
18
18
20
20
24
24
24
32

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

46
14
22
28
16
24
28
30
34
46
18
24
30
36
36
48
24
30
36
36

Mounting Pans
MATERIAL — Steel: (XSM)
Galvanized 12 gauge steel plate. The catalog number includes the steel
mounting pan complete with 1/4" high spacers and stainless steel
mounting screws.
MATERIAL — Aluminum: (XSA) Consult factory for availability.
MATERIAL — Phenolic: (XSB)
A special phenolic laminated material that has high mechanical and
dielectric strength. It is excellent for mounting and wiring control
equipment. The catalog number includes the phenolic board, 3/8" thick,
complete with 1/4" high spacers and stainless steel mounting screws.

Enclosure Size
Reference
Inside width x length
x 16
x8
x 11
x 12
x 13
x 10
x 18
x8
x10
x 12

5A–11

MOUNTING PANS

Hinge Set
Description:
Made of extruded aluminum alloy consisting
of two sections, female and male (with stainless
steel pin) and four stainless steel hex head bolts.
Designed to allow right or left hand removable or
non-removable installation.
Unless specified, left hand removable hinge
installation will be furnished by factory when
hinged enclosures are ordered.

Note: Catalog numbers represent complete hinge sets
necessary for enclosure assembly.

Note: No installation charge when customer specifies
factory installation of mounting pan.

191
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 192
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XCE Glass Windows
DIVISION I AND DIVISION II
CLASS I GROUPS B, C, & D; CLASS II GROUPS E, F, & G
NEMA 7, 9, NEMA 4/IP66 (OPTIONAL)

Circular
Window

Window
Viewing Area Diameter

Overall Window
Cover Diameter

Minimum Enclosure
Inside
Width / Length

XGC 10

1 1/8

3

8

XGC 20

1 15/16

4 1/8

9

XGC 30

3

5 3/16

9

XGC 40

4

6 3/8

9

XGC 52

5 1/4

7 7/8

12

XGC 66

6 11/16

10 3/8

16

XGC 80

8

12 1/8

18

All dimensions are in inches.
Glass window catalog number includes XCE cover machining and installation.
For raintight, watertight NEMA 4/IP66 option add suffix “N4”.
To order glass windows for field installations, add suffix SLF to XGC catalog no.
Consult factory for closer spacing requirements, multiple windows or
combinations of operators and windows.

5A–12

Rectangular
Window

Window
Viewing Area Size

Minimum
Enclosure
Inside Width

Minimum
Enclosure
Inside Length

XGW 0303

3X3

8

8

XGW 0305

3X5

8

10

XGW 0307

3X7

8

12

XGW 0505

5X5

10

10

XGW 0509

5X9

10

14

XGW 0707

7X7

12

12

XGW 0713

7 X 13

12

18

XGW 0909

9X9

14

14

XGW 1111

11 X 11

16

16

XGW 1313

13 X 13

18

18

All dimensions are in inches.
Glass window catalog number includes installation.
For raintight, watertight NEMA 4 option add suffix “N4”.
Consult factory for special viewing area requirement, closer spacing and to
combine windows with other window sizes or operators.

192
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 193
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

DJF and WJF External Flanged Junction Boxes

DJF DUST-TIGHT EXTERNAL FLANGED JUNCTION BOXES
CLASS II GROUPS E, F, & G; NEMA 9

DJF/WJF
Catalog
Number

Inside Nominal
Dimensions
W
L
D

Mounting
Bolt
Size

Side
Wall
Thickness

Shipping
Weight,
Pounds

061105

6

11

5

8 3/8

13 1/8

6 13/16

7 1/2

8 5/8

3/8

3/8

16

061305

6

13

5

8 1/8

15 1/8

6 13/16

9 1/2

8 5/8

3/8

3/8

18

071805

7

18

5

9 1/8

20 1/8

6 13/16

14 1/2

9 1/8

3/8

3/8

30

121806

12

18

6

14 1/2

20 1/2

7 15/16

14 3/8

14 3/4

1/2

7/16

42

122005

12

20

5

14 1/4

22 1/4

6 15/16

14 3/8

14 3/4

1/2

7/16

47

122406

12

24

6

141/4

26 1/4

7 15/16

18 3/4

14 3/4

1/2

7/16

52

122408

12

24

8

14 1/4

26 1/4

9 15/16

18 3/4

14 3/4

1/2

7/16

62

123006

12

30

6

14 3/8

32 3/8

8 1/16

22 3/4

15

5/8

1/2

67

123208

12

32

8

15

35

10 3/16

27 1/2

14 1/8

1/2

5/8

80

123608

12

36

8

14 3/8

38 3/8

10 3/16

29

14 3/4

1/2

5/8

110

Overall Dimensions
A
B
C

Mounting Lug
CL to CL
E
F

5A–13

WJF WATERTIGHT EXTERNAL FLANGED JUNCTION BOXES
NEMA 4

193
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 A 12/9/01 11:03 AM Page 194
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

DJF and WJF External Flanged Junction Boxes

5A–14
194
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 196
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XIF/XIFC Explosionproof Internal Flanged Junction Boxes & Control Enclosures

CAT. # XIF(C)________

5B–2
196
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 197
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XIF/XIFC Mounting Pans

MATERIAL — Steel: (XSM)
Galvanized 12 gauge steel plate. The catalog number
includes the steel mounting pan complete with 1/4"
high spacers and stainless steel mounting screws.
MATERIAL — Aluminum: (XSA)
Consult factory for availability.
MATERIAL — Phenolic: (XSB)
A special phenolic laminated material that has high
mechanical and dielectric strength. It is excellent for
mounting and wiring control equipment. The catalog
number includes the phenolic board, 3/8" thick,
complete with 1/4" high spacers and stainless steel
mounting screws.

Catalog
Number
(Steel)

Catalog
Number
(Aluminum)

Catalog
Number
(Phenolic)

Pan
Dimensions
Width
Length

Enclosure Size
Reference
Inside Width x Length

Weight
Each (pounds)
(Steel)

XSM 0303

XSA 0303

XSB 0303

3

XSM 0306

XSA 0306

XSB 0306

3

3

3x3

1/4

5 1/2

3x6

XSM 0307

XSA 0307

XSB 0307

3

6 1/2

1/2

3x7

1/2

XSM 0309

XSA 0309

XSB 0309

3

XSM 0311

XSA 0311

XSB 0311

3

8 1/2

3x9

3/4

10 1/2

3 x 11

XSM 0313

XSA 0313

XSB 0313

3

1

12 1/2

3 x 13

1 1/4

XSM 0315

XSA 0315

XSB 0315

3

14 1/2

3 x 15

1 1/2

XSM 0318

XSA 0318

XSM 0324

XSA 0324

XSB 0318

3

17 1/2

3 x 18

1 3/4

XSB 0324

3

23 1/2

3 x 24

XSM 0330

2 1/4

XSA 0330

XSB 0330

3

29

3 x 30

2 3/4

XSM 0336

XSA 0336

XSB 0336

3

35

3 x 36

3 1/4

XSM 0406

XSA 0406

XSB 0406

3 7/8

5 1/2

4x6

3/4

XSM 0412

XSA 0412

XSB 0412

3 7/8

11 1/2

4 x 12

1 1/2

XSM 0606

XSA 0606

XSB 0606

51/2

51/2

6x6

1

XSM 0612

XSA 0612

XSB 0612

5 1/2

11 1/2

6 x 12

2

XSM 0618

XSA 0618

XSB 0618

5 5/8

16 7/8

6 x 18

3

XSM 0624

XSA 0624

XSB 0624

5 5/8

22 7/8

6 x 24

4

XSM 0636

XSA 0636

XSB 0636

5 5/8

34 7/8

6 x 36

6

XSM 0707

XSA 0707

XSB 0707

6 1/2

6 1/2

7x7

1 1/2

XSM 0716

XSA 0716

XSB 0716

6 1/2

15 1/2

7 x 16

3

XSM 0832

XSA 0832

XSB 0832

7 1/2

31 1/2

8 x 32

7 1/2

5B–3

Note: No installation charge when customer specifies
factory installation of mounting pan.

When ordering separately, be sure to designate that mounting pan is for XIF series
enclosure and specify size of box.

197
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.5 BCD 12/9/01 11:05 AM Page 198
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

DIF and WIF Junction Boxes

DIF DUST-TIGHT INTERNAL FLANGED JUNCTION BOXES
CLASS II GROUPS E, F, & G; NEMA 9
WIF WATERTIGHT INTERNAL FLANGED JUNCTION BOXES
NEMA 3, 4

5B–4

DIF/WIF
Catalog
Number

Inside Nominal
Dimensions
W
L
D

Mounting
Bolt
Size

Side
Wall
Thickness

Shipping
Weight,
Pounds

101406

10

14

6

10 3/4

14 3/4

7 5/16

12 3/8

10 3/4

3/8

3/8

28

164810

16

48

10

17

49

11 5/8

19

41 1/16

5/8

1/2

150

202408

20

24

8

21

25

9 9/16

22 3/8

17 1/2

1/2

1/2

90

202412

20

24

12

21

25

13 9/16

22 1/2

17 1/2

1/2

1/2

106

243608

24

36

8

25

37

9 5/8

27 1/4

28

5/8

1/2

146

364808

36

48

8

37

49

9 3/8

39 1/4

41

5/8

1/2

242

242414

24

24

14

25

25

15 9/16

26 1/2

17 1/2

1/2

1/2

120

Overall Dimensions
A
B
C

Mounting Lug
CL to CL
E
F

Note: WIF Series includes a one piece neoprene gasket. Mounting lugs optional.
DIF Series does not include mounting lugs or gasket.

198
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 266
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures & Components - IEC Motor Control

8D–1

Explosionproof enclosures suitable for housing IEC
(International Electrotechnical Commission) style motor
starters and combination starters. Sizes from 8” x 8” x 4”
up to 12” x 18” x 6”. Design options include: pushbutton
and switch operators, pilot lights, push-to-test lights,
breather/drains, auxiliary contacts, Lamacold™ nameplates,
and control transformers with fuse blocks.
Enclosures are classified by UL/cUL as to explosion
and fire hazards.
Compliances:
Class I, Groups C, D
Class II, Groups E, F, G
Type 4
IEC Motor Starters - Starters Included

IEC Combination Motor Starters - Components Included

For ABB Components

For ABB Components

Catalog
Number

Enclosure
Size

Amp
Rating

HP at
480 Volts

Catalog
Number

Enclosure
Size

Amp
Rating

HP at
480 Volts

XSIAA9
XSIAA11
XDIAA17
XSIAA25
XSICA28
XSICA32
XSICA41
XSICA54
XSIDA65
XSIDA80
XSIEA110

XCE 080804
XCE 080804
XCE 080804
XCE 080806
XCE 101006
XCE 101006
XCE 101006
XCE 101006
XCE 101206
XCE 101206
XCE 1014D6

9
11
17
25
28
32
41
54
65
80
110

5
7.5
10
15
20
25
30
40
50
60
75

XCIAA9
XCIAA11
XCIAA17
XCIAA25
XCIAA28
XCIAA32
XCIAA41
XCIAA54
XCIAA65
XCIBB80
XCIBB110

XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 121806
XCE 121806

9
11
17
25
28
32
41
54
65
80
110

5
7.5
10
15
20
25
30
40
50
60
75

For Cutler-Hammer Components
XSIAH10
XSIAH12
XSIAH18
XSIAH25
XSICH32
XSICH37
XSICH44
XSICH60
XSIDH73

XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE

080804
080804
080804
080804
101006
101006
101006
101006
101206

For Cutler-Hammer Components

9
12
18
25
32
37
44
60
73

5
7.5
10
15
20
25
30
40
50

9
12
17
25
28
32
40
50
65
80
95

5
7.5
10
15
20
25
30
40
50
60
75

9
12
18
25
32
37
40
50
65
80

5
7.5
10
15
20
25
30
40
50
60

XCIAH10
XCIAH12
XCIAH18
XCIAH25
XCIAH32
XCIAH37
XCIAH44
XCIAH60
XCIAH73

For Siemens Components
XSIAS9
XSIAS12
XSIAS17
XSIAS25
XSICS28
XSICS32
XSICS40
XSICS50
XSIDS65
XSIDS80
XSIDS95

XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE

080804
080804
080804
080804
101006
101006
101006
101006
101206
101206
101206

266

XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE

080804
080804
080804
080806
080806
101006
101006
101006
101206
101206

1014D6
1014D6
1014D6
1014D6
1014D6
1014D6
1014D6
1014D6
1014D6

10
12
18
25
32
37
44
50
73

5
7.5
10
15
20
25
30
40
50

9
12
17
25
28
32
40
50
65
80
95

5
7.5
10
15
20
25
30
40
50
60
75

9
12
18
25
32
37
40
50
65
80

5
7.5
10
15
20
25
30
40
50
60

For Siemens Components
XCIAS9
XCIAS12
XCIAS17
XCIAS25
XCIAS28
XCIAS32
XCIAS40
XCIAS50
XCIBS65
XCIBS80
XCIBS95

For Square D Components
XSIAD9
XSIAD12
XSIAD18
XSIBD25
XSIBD32
XSICD37
XSICD40
XSICD50
XSIDD65
XSIDD80

XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE
XCE

XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 121806
XCE 121806
XCE 121806

For Square D Components
XCIAD9
XCIAD12
XCIAD18
XCIAD25
XCIAD32
XCIAD37
XCIAD40
XCIAD50
XCIAD65
XCIBD80

XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 1014D6
XCE 121806

For Group B applications, consult factory

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 267
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures & Components - IEC Motor Control
IEC Motor Starters
Enclosures only

IEC Combination Motor Starters
Enclosures only

Catalog
Number

Enclosure
Size

For ABB Components
Amp
Rating

HP at
480 Volts

Catalog
Number

Enclosure
Size

Amp
Rating

HP at
480 Volts

XSIAA
XSIAA
XSIAA
XSIAA

XCE
XCE
XCE
XCE

080804
080804
080804
080804

9
11
17
25

5
7.5
10
15

XCIAA
XCIAA
XCIAA
XCIAA

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

9
11
17
25

5
7.5
10
15

XSICA
XSICA
XSICA
XSICA

XCE
XCE
XCE
XCE

101006
101006
101006
101006

28
32
41
54

20
25
30
40

XCIAA
XCIAA
XCIAA
XCIAA

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

28
32
41
54

20
25
30
40

XSIDA
XSIDA
XSIEA

XCE 101206
XCE 101206
XCE 1014D6

65
80
110

50
60
75

XCIAA
XCIBB
XCIBB

XCE 1014D6
XCE 121806
XCE 121806

65
80
110

50
60
75

For Cutler-Hammer Components

8D–2

For ABB Components

For Cutler-Hammer Components

XSIAH
XSIAH
XSIAH
XSIAH

XCE
XCE
XCE
XCE

080804
080804
080804
080804

10
12
18
25

5
7.5
10
15

XCIAH
XCIAH
XCIAH
XCIAH

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

10
12
18
25

5
7.5
10
15

XSICH
XSICH
XSICH
XSICH
XSIDH

XCE
XCE
XCE
XCE
XCE

101006
101006
101006
101006
101206

32
37
44
60
73

20
25
30
40
50

XCIAH
XCIAH
XCIAH
XCIAH
XCIAH

XCE
XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6
1014D6

32
37
44
60
73

20
25
30
40
50

For Siemens Components

For Siemens Components

XSIAS
XSIAS
XSIAS
XSIAS

XCE
XCE
XCE
XCE

080804
080804
080804
080804

9
12
17
25

5
7.5
10
15

XCIAS
XCIAS
XCIAS
XCIAS

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

9
12
17
25

5
7.5
10
15

XSICS
XSICS
XSICS
XSICS

XCE
XCE
XCE
XCE

101006
101006
101006
101006

28
32
40
50

20
25
30
40

XCIAS
XCIAS
XCIAS
XCIAS

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

28
32
40
50

20
25
30
40

XSIDS
XSIDS
XSIDS

XCE 101206
XCE 101206
XCE 101206

65
80
95

50
60
75

XCIBS
XCIBS
XCIBS

XCE 121806
XCE 121806
XCE 121806

65
80
95

50
60
75

For Square D Components

For Square D Components

XSIAD
XSIAD
XSIAD
XSIBD

XCE
XCE
XCE
XCE

080804
080804
080804
080806

9
12
18
25

5
7.5
10
15

XCIAD
XCIAD
XCIAD
XCIAD

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

9
12
18
25

5
7.5
10
15

XSIBD
XSICD
XSICD
XSICD

XCE
XCE
XCE
XCE

080806
101006
101006
101006

32
37
40
50

20
25
30
40

XCIAD
XCIAD
XCIAD
XCIAD

XCE
XCE
XCE
XCE

1014D6
1014D6
1014D6
1014D6

32
37
40
50

20
25
30
40

XSIDD
XSIDD

XCE 101206
XCE 101206

65
80

50
60

XCIAD
XCIBD

XCE 1014D6
XCE 121806

65
80

50
60

267
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 268
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures & Components - IEC Motor Control
Diagram Specifications
Starters Diagram

Catalog
No.

Base
Enclosure
XCE

A

Overall
B

C

MTG
E

MTG
F

MTG
BOLT

080804
080806
101006
101206
1014D6

11.38
11.38
13.38
13.38
13.38

11.38
11.38
13.38
15.38
17.38

7.75
9.75
9.62
10.25
9.75

4.25
4.25
6.5
8.5
10.62

11
11
13
13.25
13.25

3/8
3/8
3/8
3/8
3/8

2.81
3.81
3.88
4.13
2.88

2.25
2.25
2.50
2.5
2.5

1-1/2
1-1/2
2
2
2

26
30
46
48
51

13.38
16.25

17.38
22.25

9.75
10.12

10.62
14.12

13.25
15.75

3/8
1/2

2.88
4.00

3.0
3.0

1-1/2
2

51
95

Conduit Location Conduit
D
G
Size

Weight

Starters

8D–3

XSIA
XSIB
XSIC
XSID
XSIE

Combinations
XCIA
XCIB

1014D6
121806

Options
Suffix

Combination
Starter

Available On
Non-Combination
Starter

Start/Stop Dual Pushbutton
(1NO Start, 1NC Stop)

A

•

•

•

Green Start Pushbutton (1NO)

A1

•

•

•

Red Stop Pushbutton (1NC)

A2

•

•

•

Red Stop Pushbutton,
Mushroom Head (1NC)

A3

•

•

•

Black Pushbutton (1NO, 1NC)

A4

•

•

•

Hand-Off-Auto Selector Switch

B

•

•

•

Selector Switch (2-Position)
(1NO, 1NC)

B1

•

•

•

Pilot Light 120 Volt AC
(*See Color Table)

C1*

•

•

•

Pilot Light with Guard 120 Volt AC
(*See Color Table)

CG1*

•

•

•

Push-to-Test Light 120 Volt AC
(1NO, 1NC) (*See Color Table)

CP1*†

•

•

•

E

•

•

•

EE

•

•

•

G(+ -)

•

•

Lamacold Nameplate (Specify Legend) NP

•

•

50 VA Control Transformer 480V Pri,
120V Sec. W/Fuse Block

T1F

•

•

100 VA Control Transformer 480V Pri,
120V Sec. W/Fuse Block

T2F

•

•

150 VA Control Transformer 480V Pri,
120 V Sec. W/Fuse Block

T3F

•

•

200 VA Control Transformer 480V Pri,
120V Sec. W/Fuse Block

T4F

•

•

Description

Combination Diagram

Breather/Drain Installed in Bottom
Breather and Drain Installed
Auxiliary Contacts on Starter
(+NO,-NC) (Specify No. of Contacts)

Universal
Enclosure Only

•

*Color Table R-Red G-Green A-Amber B-Blue C-Clear W-White
†Not available in Group B applications

268
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 171
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XIH Explosionproof Instrument Housing

4A–1

Largest
Product Line
Available
Anywhere!

!
NEW
XIHMK 316SS & Aluminum 39/16" ID

XIHL & XDHL 4" ID Aluminum
XIHM 39/16" & 35/8" ID Aluminum
XDHM 35/8" ID Aluminum
XIH & XDH 33/16" ID Aluminum
XIHS 25/8" ID Aluminum
XDF Custom Digital Enclosure
(ATEX available on some models)

171
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 172
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XIHMK Explosionproof Instrument Housing (316 Stainless or Aluminum)
3 9/16" ID Enclosure
Solid Cover Arrangements

Glass Cover Arrangements

4 1⁄4"

4 3⁄4"

3 9⁄16"
3 9⁄16"

3 5⁄16"

3 1⁄16"

Catalog
Number

Description

XIHMKFCX

Flat Cover 3⁄4" NPT Hubs

Catalog
Number

Description

XIHMKFGCX Flat Glass Cover 3⁄4" NPT Hubs

Standard Features
XIHMK housings accommodate large diameter assemblies,
multi-level circuit boards or wide angle readouts and displays.
The 3-9 ⁄ 16" ID provides maximum clearance to facilitate
instrument mounting, calibration or service. Precision
machined from sand-cast, copper-free aluminum.
XIHMK housings feature:

5"

5 5⁄32"

• 3⁄4" NPT conduit feed-through hubs offset
for maximum clearance and capacity
• 7⁄16" thick base for blind tapped instrument mounting holes
in any location

4A–2

• Glass cover models have a large 2-1/2" diameter, tempered
glass window for local read out
• 45° chamfer on window opening provides enhanced viewing
angle

51⁄ 2"

• Buna-N rubber gasket for NEMA 4X watertight applications

Certifications

• Front boss for use as additional conduit or sensor entry
• Corrosion resistant, “safety blue” polyester powder coating
(other colors available)

FM STANDARD 3615
CSA STANDARD C22.2 NO. 30

• Internal and external ground screws and tamper resistant
cover set screw for extra safety

UL STANDARD 1203

• Stainless steel hardware

DEMKO CENELEC STANDARD EN 50014, 50018

Design Options
• Mounting lugs with 5⁄16" holes
• Additional small hole drilling and tapping in the backwall for
mounting of instrumentation

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIC, IP66
NEMA 4X, 7BCD, 9EFG

• 1⁄2" NPT or 3⁄4" NPT opening into back wall for conduit,
sensor or probe
• Front Boss Modifications: 1⁄2", 3⁄4" or 1" NPT; 1⁄2", 3⁄4" or 1"
NPSM; or 20mm or 25mm for sensor, probe or conduit
entry
• 1⁄2" NPT reducers are available – add suffix “2” to
catalog number

172
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 173
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XIHL (Explosionproof Instrument Housing — Large)
4" ID Enclosure

Solid Cover Arrangements

Glass Cover Arrangements

5 1⁄8"

5 5⁄8"

4"

4"

3 3⁄4"

4"

Standard Features
Catalog
Number

Description

XIHLFCX

Flat Cover 3⁄4" NPT Hubs

Catalog
Number

XIHL housings accommodate large diameter
assemblies, multi-level circuit boards or wide
angle readouts and displays. The 4" ID provides
maximum clearance to facilitate instrument
mounting, calibration or service. Precision
machined from sand-cast copper-free aluminum.

Description

XIHLFGCX Flat Glass Cover 3⁄4" NPT Hubs

XIHL housings feature:
6"

7 1⁄8"

5 3⁄4"

7 5⁄8"

• 3⁄4" NPT conduit feed-through hubs offset
for maximum clearance and capacity
• 1⁄ 2" thick base for blind tapped instrument
mounting holes in any location

4"

• Glass cover models have a large 3 5⁄16"
diameter, tempered glass window for local
read out

4"

• Buna-N rubber gasket for NEMA 4X watertight
applications

Catalog
Number

Description

Catalog
Number

XIHLDCX

Dome Cover 3⁄4" NPT Hubs

XIHLDGCX

Description
Dome Glass Cover 3⁄4" NPT Hubs

4A–3

• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)
• Internal and external ground screws and
tamper resistant cover set screw for
extra safety
• Stainless steel hardware

5 7⁄16"

Design Options
• Four 1⁄4–20 UNC holes in front boss for bracket
mounting
5"

5 5⁄8"

• Front Boss Modifications: 1⁄ 2" to 1" NPT, 1⁄ 2" to
3⁄4" NPSM or 20 mm for sensor, probe or
conduit entry. Consult factory for other sizes.
• 1⁄ 2" NPT reducers are available – add suffix “2”
to catalog number

Certifications

4 1⁄16"
5⁄16"

Diameter Mounting Lugs
FM STANDARD 3615
CSA STANDARD C22.2 NO. 30
UL STANDARD 1203

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIC, IP66
NEMA 4X, 7BCD, 9EFG

KEMA CENELEC STANDARD EN 50014, 50018

173
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 174
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XDHL (Explosionproof Double-Ended Housing — Large)
4" ID Enclosure

Solid Cover Arrangements

4"

4"

5"
4"

13⁄16"

Standard Features

2 1⁄8"

XDHL housings are designed to isolate incoming
power connections from instrumentation. The 4"
ID provides maximum clearance to facilitate
instrument mounting, calibration or service, with
back-to-back chambers separated by a solid, 1⁄ 2"
thick wall. Precision machined from sand-cast,
copper-free aluminum.

Glass Cover Arrangements

Catalog
Number

Description

XDHLFCX

Flat Cover 3⁄4" NPT Hubs

5 1⁄2"
3 3⁄4"

13⁄16"

2 1⁄8"

2 5⁄8"

Catalog
Number

2 5⁄8"

Description

XDHLFGCX Flat Glass Cover 3⁄4" NPT Hubs

XDHL housings feature:
• 3⁄4" NPT conduit feed-through hubs, offset into
power side for maximum clearance and capacity
• Front boss with 3⁄4" NPT opening into
instrument side for conduit, sensor or probe
(see design options for other sizes)

7"
71⁄2"
4"

4"

• Internal and external ground screws and tamper
resistant cover set screws for extra safety

6"

13⁄16"

• A choice of solid covers or 3 5⁄16" diameter
tempered glass window for local read out
and display

4A–4

2 1⁄8"

• Buna-N rubber gasket for NEMA 4X
watertight applications
• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)

Catalog
Number

• Stainless steel hardware

13⁄16"

Catalog
Number

XDHLDCX Dome Cover 3⁄4" NPT Hubs

Design Options

2 1⁄8"

2 5⁄8"

Description

5 3⁄4"

Description

XDHLDGCX Dome Glass Cover 3⁄4" NPT Hubs

53⁄8"

• 2- to 12-point, power side terminal strip with
sealed pass-through to instrument (add suffix
“2T”, “4T”, “6T”, “8T”, “10T” or “12T” to
catalog number)

1 5⁄ 16"

• Internal wall can be modified (Drilled &
Tapped) to suit design needs – please consult
factory
• Power side cover options:
Flat Solid
Dome Glass
Flat Glass
Dome Solid

—
—
—
—

5 5⁄8"

Standard
Add Suffix “A”
Add Suffix “B”
Add Suffix “C”

• Front Boss Modifications: 1⁄ 2", 3 ⁄4" or 1" NPT;
1⁄ 2", 3 ⁄4" or 1" NPSM; or 20mm, 25mm or
30mm for sensor, probe or conduit entry

2 5⁄8"

2 1⁄4"

Certifications
FM STANDARD 3615

• 1⁄ 2" NPT reducers are available – add suffix “2”
to catalog number

CSA STANDARD C22.2 NO. 30

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIB+H2, IP66
NEMA 4X, 7BCD, 9EFG

UL STANDARD 1203

• Four 1⁄4–20 UNC holes in front boss for bracket
mounting. (Consult factory for other sizes)

KEMA CENELEC STANDARD EN 50014,50018

174
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 175
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XIHM (Explosionproof Instrument Housing — Medium)
3 9/16" ID Enclosure (Standard)
3 5/8" ID Enclosure (Available - see note)
Solid Cover Arrangements

4 1⁄4"

Glass Cover Arrangements

*

4 3⁄4"

3 9⁄16"
3 9⁄16"

*

Standard Features

3 1⁄16"

XIHM housings accommodate large diameter
assemblies, multi-level circuit boards or wide
angle readouts and displays. The 3 9⁄16" ID
provides maximum clearance to facilitate
instrument mounting, calibration or service.
Precision machined from sand-cast, copper-free
aluminum.
XIHM housings feature:

* Midsize solid cover available –
add 11/16" to above dimensions.

*

Catalog
Number

Description

XIHMFCX

Flat Cover 3⁄4" NPT Hubs

XIHMMCX

Mid Size Cover
3/4" NPT Hubs

Catalog
Number

Description

XIHMFGCX Flat Glass Cover 3⁄4" NPT Hubs

6 3⁄8"
4 3⁄4"
6 11⁄16"
7 5⁄8"

3 9⁄16"

3 9⁄16"

Catalog
Number
Catalog
Number

Description

XIHMDCX

Dome Cover 3⁄4" NPT Hubs

Description

XIHMDGCX Dome Glass Cover 3⁄4" NPT Hubs

Design Options

5"

5 1⁄4"
4 5⁄8"

3 7⁄ 8"

Certifications
FM STANDARD 3615
CSA STANDARD C22.2 NO. 30

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIC, IP66
NEMA 4X, 7BCD, 9EFG

• 3⁄4" NPT conduit feed-through hubs offset
for maximum clearance and capacity
• 7⁄ 16" thick base for blind tapped instrument
mounting holes in any location
• Glass cover models have a large 2 5⁄8" diameter,
tempered glass window for local read out
• 60° chamfer on window opening provides
enhanced viewing angle
• Buna-N rubber gasket for NEMA 4X watertight
applications
• Front boss for bracket mounting or for use as
additional conduit or sensor entry
• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)
• Internal and external ground screws and tamper
resistant cover set screw for extra safety
• Stainless steel hardware

4A–5

3 5⁄16"

UL STANDARD 1203
DEMKO CENELEC STANDARD EN 50014, 50018

• Mounting lugs with 5⁄16" holes (add suffix “L”
to catalog number)
• Additional small hole drilling and tapping in the
backwall for mounting of instrumentation
• 1⁄2" NPT or 3⁄4" NPT opening into back wall for
conduit, sensor or probe
• Front Boss Modifications: 1⁄2", 3⁄4" or 1" NPT;
1⁄2", 3⁄4" or 1" NPSM; or 20mm or 25mm for
sensor, probe or conduit entry
• Throat diameter can be increased to 3 5⁄8" –
please consult factory
• Glass window covers designed for Groups C
and D only (CENELEC: EExd IIB) are also
available – please consult factory for pricing
• 1⁄ 2" NPT reducers are available – add suffix “2”
to catalog number
• Four 1⁄4–20 UNC holes in front boss for bracket
mounting. (Consult factory for other sizes.)

175
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 176
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XDHM (Explosionproof Double-Ended Housing — Medium)
3 5/8" ID Enclosure

Solid Cover Arrangements

3 5⁄8"

4 5⁄16"

Glass Cover Arrangements

*

* 3 5⁄16"

13⁄16"

4 13⁄16"

3 5⁄8"
3 1⁄16"

13⁄16"

Standard Features
XDHM housings are designed to isolate incoming
power connections from instrumentation. The 3 5⁄8"
ID provides maximum clearance to facilitate
instrument mounting, calibration or service, with
back-to-back chambers separated by a solid, 1⁄2"
thick wall. Precision machined from sand-cast,
copper-free aluminum.
XDHM housings feature:

4A–6

• 3⁄4" NPT conduit feed-through hubs, offset into
power side for maximum clearance and capacity
• Front boss with 3⁄4" NPT opening into
instrument side for conduit, sensor or probe
(see design options for other sizes)
• Internal and external ground screws and tamper
resistant cover set screws for extra safety
• A choice of solid covers or 2 5⁄8" diameter
tempered glass window for local read out
and display
• 60° chamfer on window opening provides
enhanced viewing angle
• Buna-N rubber gasket for NEMA 4X
watertight applications
• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)
• Stainless steel hardware

* 1 7⁄16"

*

• 2- to 8-point, power side terminal strip with
sealed pass-through to instrument (add suffix
“2T”, “4T”, “6T” or “8T” to catalog number)
• Internal wall can be modified (drilled & tapped) to
suit design needs - please consult factory
• Power side cover options:
—
—
—
—
—

Description

XDHMFCX

Flat Cover 3⁄4" NPT Hubs

XDHMMCX

Mid Size Cover
3/4" NPT Hubs

115⁄16"

Catalog
Number

Description

XDHMFGCX

Flat Glass Cover 3⁄4" NPT Hubs

*

6 7⁄16"
7 11⁄16"
3 5⁄8"
3 5⁄8"
13⁄16"

4 3⁄4"

6 11⁄16"

13⁄16"

*1 7⁄16"
*

1 7⁄16"

115⁄16"

Catalog
Number

Description

XDHMDCX

Dome Cover 3⁄4" NPT Hubs

115⁄16"

*

*
Catalog
Number

Description

XDHMDGCX Dome Glass Cover 3⁄4" NPT Hubs

5"

Standard
Add Suffix “A”
Add Suffix “B”
Add Suffix “C”
Add Suffix “D”

• Front Boss Modifications: 1⁄2", 3⁄4" or 1" NPT;
1⁄2", 3⁄4" or 1" NPSM; or 20mm or 25mm
opening modify for sensor, probe or conduit
entry
• Glass window covers designed for Groups C
and D only (CENELEC: EExd IIB) are also
available – please consult factory for pricing
•

Catalog
Number

* 1 7⁄16"

*

* Midsize solid cover available –
add 11/16" to above dimensions.

Design Options

Flat Solid
Dome Glass
Flat Glass
Dome Solid
Midsize Solid

115⁄16"

5 1⁄4"

1 1⁄ 8"

2 1⁄4"

Certifications

1⁄ 2"

NPT reducers are available – add suffix “2”
to catalog number

FM STANDARD 3615

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIC, IP66
NEMA 4X, 7BCD, 9EFG

CSA STANDARD C22.2 NO. 30

• Four 1⁄4–20 UNC holes in front boss for bracket
mounting. (Consult factory for other sizes.)

UL STANDARD 1203
DEMKO CENELEC STANDARD EN 50014, 50018

176
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 177
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XIH (Explosionproof Instrument Housing)
3 3/16" ID Enclosure

Solid Cover Arrangements

Glass Cover Arrangements

3 7⁄16"

3 3⁄16"

3 13⁄16"

3 3⁄16"

2 9⁄16"

Catalog
Number
XIHFCX2
XIHFCX3

2 3⁄16"

Catalog
Number

Description
Flat Cover 1⁄2" NPT Hubs
Flat Cover 3⁄4" NPT Hubs

4 15⁄16"

XIHFGCX2
XIHFGCX3

Description
Flat Glass Cover
Flat Glass Cover

5 13⁄16"

4 7⁄16"

3 3⁄16"

Standard Features

1⁄2" NPT Hubs
3⁄4" NPT Hubs

XIH housings are designed for small to medium
size electronic assemblies. The 3 3 ⁄16" ID
provides ample clearance to accommodate a
wide variety of measurement and control
devices. Precision machined from sand-cast
copper-free aluminum.
XIH housings feature:
6"

• Four interior mounting bosses at 45°
orientation accommodate blind tapped holes
on a 2 1⁄2" bolt circle
• 1⁄2" or 3 ⁄4" NPT conduit feed-through hubs,
offset for maximum clearance and capacity

3 3 ⁄16"

• Internal and external ground screws and
tamper resistant cover set screw for extra
safety

XIHDCX2
XIHDCX3

Catalog
Number

Description
Dome Cover
Dome Cover

1⁄2" NPT Hubs
3⁄4" NPT Hubs

XIHDGCX2
XIHDGCX3

• Glass cover models have a 2 5 ⁄8" diameter,
tempered glass window for local read out

Description
Dome Glass Cover 1⁄2" NPT Hubs
Dome Glass Cover 3⁄4" NPT Hubs

4A–7

Catalog
Number

• Buna-N rubber gasket for NEMA 4X watertight
applications
• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)
• Stainless steel hardware

4 1⁄2"

Design Options
• Four 1⁄4-20 UNC holes in front boss for bracket
mounting. Consult factory for other sizes.

4 1⁄8"
4 13⁄16"

• Front Boss Modifications: 1⁄2" or 3 ⁄4" NPT for
sensor, probe or conduit entry
• Mounting lugs with 5⁄16" holes (add suffix “L”
to catalog number)
• Other interior mounting bosses available –
please consult factory

3 1⁄4"

Certifications
FM STANDARD 3615
CSA STANDARD C22.2 NO. 30

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIC, IP66
NEMA 4X, 7BCD, 9EFG

UL STANDARD 1203 (Consult factory for availability)
ISSEP CENELEC STANDARD EN 50014, 50018

177
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 178
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XDH (Explosionproof Double-Ended Housing)
3 3/16" ID Enclosure

Solid Cover Arrangements

3 3⁄16"
2 11⁄16"
3⁄4"

3⁄4"

1 5⁄16"

3 7⁄8"

3 3⁄16"

3 1⁄2"

2 5⁄16"

1 5⁄16"

17⁄8"

Standard Features
XDH housings are designed to isolate incoming
power connections from instrumentation. The
3 3⁄16" ID provides ample clearance to accommodate a wide variety of measurement and control
devices, with back-to-back chambers separated
by a solid, 3⁄8" thick wall. Precision machined from
sand-cast copper-free aluminum.
XDH housings feature:

Glass Cover Arrangements

17⁄8"

Catalog
Number

Description

Catalog
Number

Description

XDHFCX

Flat Cover 3⁄4" NPT Hubs

XDHFGCX

Flat Glass Cover 3⁄4" NPT Hubs

• 3⁄4" NPT conduit feed-through hubs, offset into
power side for maximum clearance and capacity

5 7⁄8"

• Front boss with 3⁄4" NPT opening into
instrument side for conduit, sensor or probe
(see design options for other sizes)

6 1⁄16"
3 3⁄16"

3 3⁄16"
3⁄4"

• Internal and external ground screws and tamper
resistant cover set screws for extra safety

5 1⁄16"

3⁄4"

1 5⁄16"

4A–8

• Buna-N rubber gasket for NEMA 4X watertight
applications
• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)
• Stainless steel hardware

1 5 ⁄16"

17⁄8"

• A choice of solid covers or 2 5⁄8" diameter
tempered glass window for local read out
and display

4 9⁄16"

17⁄8"

Catalog
Number

Description

Catalog
Number

Description

XDHDCX

Dome Cover 3⁄4" NPT Hubs

XDHDGCX

Dome Glass Cover 3⁄4" NPT Hubs

4 1⁄2"

Design Options
• 2- or 4-point, power side terminal strip with
sealed pass-through to instrument (add suffix
“2T” or “4T” to catalog number)

13⁄ 16"

4 11 ⁄16"

• Power side cover options:
Flat Solid
— Standard
Dome Glass — Add Suffix “A”
Flat Glass
— Add Suffix “B”
Dome Solid — Add Suffix “C”

2 1⁄4"

• Four 1⁄4–20 UNC holes in front boss for bracket
mounting. (Consult factory for other sizes.)
• Front Boss Modifications: 1⁄ 2" or 3⁄ 4" for sensor,
probe or conduit entry
• 1⁄ 2" NPT conduit entries are available – add
suffix “2” to catalog number.

Certifications

Class I, Groups B,C,D
Class II, Groups E,F,G
Class III
CENELEC: EExd IIC, IP66
NEMA 4X, 7BCD, 9EFG

FM STANDARD 3615
CSA STANDARD C22.2 NO. 30
ISSEP CENELEC STANDARD EN 50014, 50018

178
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.4 12/9/01 10:59 AM Page 179
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

XIHS (Explosionproof Instrument Housing — Small)
2 5/8" ID Enclosure
Cover
Arrangements
4"

3⁄16"

3 1 ⁄2"

3 1 ⁄2"

3 1 ⁄2"

Flat
Cover

Dome
Cover

Dome
Glass Cover

Catalog
Number

Base Styles

Conduit
Size
1⁄2"

“B”

XIHSBFC2
XIHSBFC3
XIHSBFC4
XIHSCFC2
XIHSCFC3
XIHSCFC4

1⁄2"

“C”

“D”

XIHSDFC3
XIHSDFC4

3⁄4"

XIHSLFC2
XIHSLFC3
XIHSLFC4

1⁄2"

“L”

“T”

XIHSTFC2
XIHSTFC3
XIHSTFC4

1⁄2"

XIHSXFC2
XIHSXFC3
XIHSXFC4

1⁄2"

“X”

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

NPT
1" NPT
NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

XIHSYFC23 ONE 1⁄2" NPT
ONE 3⁄4" NPT

“Y”

2 5⁄8"

2 5⁄8"

2 5⁄8"

5 3⁄4"

Catalog
Number

Conduit
Size

Catalog
Number

Conduit
Size

XIHSBDC2
XIHSBDC3
XIHSBDC4

1⁄2"

XIHSBDGC2
XIHSBDGC3
XIHSBDGC4

1⁄2"

XIHSCDC2
XIHSCDC3
XIHSCDC4

1⁄2"

XIHSCDGC2
XIHSCDGC3
XIHSCDGC4

1⁄2"

XIHSDDC3
XIHSDDC4

3⁄4"

XIHSDDGC3
XIHSDDGC4

3⁄4"

XIHSLDC2
XIHSLDC3
XIHSLDC4

1⁄2"

XIHSLDGC2
XIHSLDGC3
XIHSLDGC4

1⁄2"

XIHSTDC2
XIHSTDC3
XIHSTDC4

1⁄2"

XIHSTDGC2
XIHSTDGC3
XIHSTDGC4

1⁄2"

XIHSXDC2
XIHSXDC3
XIHSXDC4

1⁄2"

XIHSXDGC2
XIHSXDGC3
XIHSXDGC4

1⁄2"

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

NPT
1" NPT
NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

XIHSYDC23 ONE 1⁄2" NPT
ONE 3⁄4" NPT

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

NPT
1" NPT
NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

3⁄4"

NPT
NPT
1" NPT

Standard Features
XIHS housings are designed to accommodate
small instruments or devices. The 2 5⁄8" ID
enclosure is offered in six different conduit
configurations and a choice of cover arrangements.
Precision machined from sand-cast, copper-free
aluminum.
XIHS housings feature:
•
•
•

•
•

3⁄4"

XIHSYDGC23 ONE 1⁄2" NPT
ONE 3⁄4" NPT

•

1⁄2", 3⁄4" or 1" NPT conduit feed-through hubs for
power
Internal ground screw
Interior instrument mounting bosses that
accommodate blind tapped holes on a
2" bolt circle
Glass cover arrangements with a 1 1⁄8" diameter tempered glass window for local read out
Buna-N rubber gasket for NEMA 4X watertight
applications
Tumblast, natural aluminum finish

Design Options
• Corrosion resistant, “safety blue” polyester
powder coating (other colors available)

Certifications

Note: Above dimensions are for 1/2" and 3/4" NPT. For 1" NPT
housings, add 5/16" to height dimensions.

FM STANDARD 3615
CSA STANDARD C22.2 NO. 30

Class I, Groups B, C and D
Class II, Groups E,F,G
Class III
NEMA 4X, 7BCD, 9EFG

UL STANDARD 1203

E

A

C

E

E

A

C
D

D

B
F
“D”

“B”
CONDUIT
SIZE

A

B

C

D

E

F

1/2

3 1/2

2 1/16

2 5/8

1

11/16

7/8

7/8

3/4

3 1/2

2 1/16

2 5/8

1

11/16

7/8

7/8

1

3 1/2

2 3/8

2 5/8

1

1

2

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

179

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

4A–9

2 5⁄8"
1 11⁄16"

4 1⁄16"

5 1⁄16"

15599 Sec.8 12/9/01 11:17 AM Page 269
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Motor Control Explosionproof Motor Starters
MANUAL MOTOR STARTERS

Catalog
Number

Number
of Hubs

Conduit
Size

Poles

Mfg. Bolt
Size

Weight
(lbs.)

XLSC21 †*

2

1/2

1

1/4"

2 3/4

XLSC22 †*

2

1/2

2

1/4"

2 3/4

XLSC31 †*

2

3/4

1

1/4"

2 3/4

XLSC32 †*

2

3/4

2

1/4"

2 3/4

XLSC2 **

2

1/2

-

1/4"

2 3/4

XLSC3 **

2

3/4

-

1/4"

2 3/4

8E–1

Type XLS Manual Motor Starting Switches are furnished complete
with switch and interchangeable heaters. The XLS housings are
cast aluminum alloy and have a trouble free operating lever
threaded through the cover.

† = HP Rating
* = Heater Table

MAXIMUM HORSEPOWER RATINGS
†Adalet
Symbol
1B
2B
1C
2C

Make & Catalog No.
Westinghouse MST01
Westinghouse MST02
GE CR101Y
GE CR101H

Poles
1
2
1
2

115-230
Volts AC
1 H.P.
1 H.P.
1 H.P.
1 H.P.

32
Volts DC
1/4 H.P.
1/4 H.P.

115
Volts DC
1/4 H.P.
1 H.P.
1 H.P.
1 H.P.

230
Volts DC
1/4 H.P.
1 H.P.
1/4 H.P
1 H.P.

The following tables list interchangeable Heater elements for each
manufacturer. The elements are not interchangeable between manufacturers. The heater elements listed are for motors rated 40°C
continuous. For motors rated 50°C or 55°C, multiply by 0.9 and
use this value to select heaters.

WESTINGHOUSE
*Adalet
Symbol
1
2
3
4
5
6
7
8
9
10
11
12
13

Motor
Full Load
Current
.40 - .43
.44- -.48
.49 - .53
.54 - .58
.59 - .64
.65 - .71
.72 - .78
.79 - .87
.88 - .95
.96 – 1.03
1.04 – 1.15
1.16 – 1.27
1.28 – 1.35

*Adalet
Symbol
14
15
16
17
18
19
20
21
22
23
24
25
26

1
2
3
4
5
6
7
8
9
10
11
12
13
14

.48
.53
.58
.65
.71
.78
.86
.95
1.04
1.14
1.25
1.37
1.49
1.63

15
16
17
18
19
20
21
22
23
24
25
26
27
28

Motor
Full Load
Current
1.36 – 1.51
1.52 – 1.67
1.68 – 1.83
1.84 – 1.99
2.00 – 2.23
2.24 – 2.47
2.48 – 2.71
2.72 – 2.95
2.96 – 3.27
3.28 – 3.59
3.60 – 3.99
4.00 – 4.39
4.40 – 4.79

*Adalet
Symbol
27
28
29
30
31
32
33
34
35
36
37
38
39

Motor
Full Load
Current
4.80 – 5.26
5.27 – 5.83
5.84 – 6.39
6.40 – 7.03
7.04 – 7.74
7.75 – 8.46
8.47 – 9.35
9.36 – 10.30
10.31 – 11.35
11.36 – 12.47
12.48 – 13.67
13.68 – 15.12
15.13 – 16.00

29
30
31
32
33
34
35
36
37
38
39
40
41

5.90
6.41
6.98
7.60
8.25
8.95
9.75
10.60
11.40
12.50
13.60
14.80
16.00

How To Order: To determine the
complete catalog number, select the unit
wanted and add the Adalet symbol
numbers for the make of starter wanted
and the heaters required. Select heaters
from charts.
** Enclosure less switch - for CSA certified
switches rated 600V max, 30 amp max,
15HP max.

GE
1.78
1.95
2.13
2.32
2.53
2.76
3.01
3.27
3.56
3.88
4.22
4.60
5.00
5.43

Certifications
Class I, Groups C & D
Class II, Groups E, F & G

LR36172
269

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 270
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Motor Control Explosionproof Motor Starter/Protector

8E–2
Compliances:
• NEC: Class I, Groups C, D
Class II, Groups E, F, G
• UL Standard 1203
Hazardous (Classified) Locations
• CSA Standard 22.2
• NEMA: 7CD, 9EFG
Approvals:
• UL Classified
Class I, Groups C, D
Class II, Groups E, F, G
• CSA Certified
Class I, Groups C, D
Class II, Groups E, F, G
270
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 260
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Motor Control Explosionproof Motor Starters

Features:

8C–1

• Lightweight, corrosion resistant, copper-free aluminum
alloy (0.3% max. copper content).
• Uniform wall thickness (not ribbed) for versatility of
conduit openings assuring 5 full thread engagement and
maximum available area for conduit drilling and tapping.
• Captive stainless steel cover bolts resist corrosion and
cannot get lost.
• Ground lug is highly visible and accessible.
• Bolted flange design provides clear access to internal
components.
• Rugged cast aluminum handle allows locking in “on” or
“off” position with as many as three padlocks.
• Clevis assembly allows closing of door with breaker
handle assembly in any position without damage to
breaker and without internal mounting hardware.
• All operating shafts are stainless steel for corrosion
resistance.
• Durable cast-on lugs cannot get lost.
• Backpan accommodates most popular brands of circuit
breaker and motor circuit protectors and motor starters.
• Two predrilled and tapped operator holes furnished with
explosionproof plugs for field installation of pilot devices.
• Two additional optional holes available.
• Aluminum hinges with stainless steel hinge pins are “liftoff” so the cover can be easily removed.

XCBSLQN4

• Easily adjustable reset button allows for starter changes in
the field.
• N4 gasket furnished as standard on combination starters.
• Narrow design on combination starter through size 2
allows closer spacing on switchracks while providing
ample room to mount control transformer on the backpan.
• XCBSAQ and XCBSBQ provided with XBO breaker handle
as standard.

Compliances:
• NEC: Class I, Groups B, C, D
Class II, Groups E, F, G
Class III

Certifications

• UL Standard 1203
Hazardous (Classified) Locations

C

CLASSIFIED E81696
CERTIFIED LR 36172

• CSA Standard C22.2 No. 30
• NEMA: 3, 3R, 4, 7BCD, 9EFG, 12

Note: Consult Factory for approvals and certifications on
specific enclosures.
260
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 261
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Motor Control Explosionproof Motor Starters

8C–2

Universal Enclosures Only
(does not include breaker or starter)
Class I, Groups C and D; Class II, Groups E, F & G;
Class III, Type 3, 3R, 4,7CD, 9EFG, 12

Class I, Groups C and D; Class II, Groups E, F & G;
Class III, Type 7CD, 9EFG Type 4

For two-speed, Y-Delta, reduced voltage, or multiple starter packages consult factory for availability.
261
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 262
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Motor Control Explosionproof Motor Starters
Combination Starter Enclosures (includes breaker and
starter) Full voltage non-reversing
8C–3
262
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 263
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Motor Control Explosionproof Motor Starters

8C–4

Combination Starter Enclosures (includes breaker and
starter) Full voltage reversing

Magnetic Full Voltage Starter Enclosures (includes starter)

263
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 264
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Motor Control Explosionproof Motor Starters
Options, Dimensions and Ordering Instructions

8C–5

Description

Suffix

Combination
Starter

Start/Stop Dual Pushbutton (1NO Start, 1NC Stop)

A

Green Start Pushbutton (1NO)

A1

Red Stop Pushbutton (1NC)

A2

Red Stop Pushbutton, Mushroom Head (1NC)

A3

Black Pushbutton (1NO, 1NC)

A4

•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

Auxiliary Switch on Breaker (1A and 1B Contacts)

AS1

Auxiliary Switch on Breaker (2A and 2B Contacts)

AS2

Hand-Off-Auto Selector Switch

B

Selector Switch (2-Position) (1NO, 1NC)

B1

Bell Alarm Switch on Breaker (Specify No. of Contacts)

BA

Pilot Light 120 Volt AC (•See Color Table)

C1*

Pilot Light with Guard 120 Volt AC (•See Color Table)

CG1*

Push-to-Test Light 120 Volt AC (1NO, 1NC) (•See Color Table)

CP1*†

Breather/Drain Installed in Bottom

E$

Breather and Drain Installed

EE$

Auxiliary Contacts on Starter (+NO, -NC) (Specify No. of Contacts)

G (+ -)

Time Delay Relay-On Delay (Specify Range)

H1

Time Delay Relay-Off Delay (Specify Range)

H2

8-Point Terminal Strip

K

Epoxy Coating External Only (Specify Color)

L1

Epoxy Coating External and Internal (Specify Color)

L2

Lamacoid Nameplate (Specify Legend)

NP

Overload Heaters (Specify Full Load Amps)

OL

Control Relay (Description Required)

R

Space Heater (Specify Wattage)

S

Shunt Trip on Breaker (Specify Voltage)

ST

50 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block††

T1F

100 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block††

T2F

150 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block††

T3F

200 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block††

T4F

250 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block††

T5F

300 VA Control Transformer 480V Pri, 120V Sec. W/Fuse Block††

T6F

Other Control Transformer (Specify VA, Pri. And Sec.)

T7

Undervoltage Release on Breaker (Specify Voltage Rating)

UV

Internal Control Wiring

W

Other (Specify)

Z

*Color Table

R-Red

G-Green

A-Amber

B-Blue

Available On
Non-Combination
Starter

Universal
Enclosure Only

•
•
•
•
•

•
•
•
•
•

•
•

•
•

•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

•
•
•
•
•

•
•
•

•
•
•
•
•
•
•
•
•
C-Clear

•
W-White

† Not available in Group B applications
†† Fuses Included
$ for Group B applications add H to the suffix

264
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 265
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Motor Control Explosionproof Motor Starters

DIMENSIONS
Nominal Dimensions In Inches
F

G

Ship.
Wt.

Cond.
Size

9 11/16

2 1/2

3&5

61

1 1/2

10 1/2

2 13/16

3&5

87

1 1/2

A

B

C

D

E

$ *XCBSAQ-N4 062305

4 1/8

25 1/2

11 1/8

26 15/16

$ *XCBSBQ-N4 072706

4 3/4

29 7/8 11 13/16

31 1/8

18 3/8 16 15/16

XCBSLQ-N4

122408

15 3/4

XCBSMQ-N4

123608

15 3/4

29

16 15/16

Est.

28 1/4

12 15/16

3

3&5

160

2

40 1/4

13 3/8

3 5/8

3&5

260

2 1/2

XCBSN-N4

164610

19 3/4

39

21 3/4

50 7/8

16 7/16

4 7/8

3&5

420

4

XCMRSG-N4

121808

15 3/4

14 1/8

17

22 1/4

12 5/8

2 13/16

3&6

100

1 1/4

XCMRSK-N4

122406

15 3/4

18 3/8

17

28 1/4

10 15/16

3 5/16

3&5

130

2

XCMRSP-N4

183608

21 3/4

29

23 3/4

40 7/8

14 3/4

4 1/8

3&5

395

2

†XMSB

081006

10 3/4

6 1/2

12

13 3/8

8 1/4

2 3/8

3&6

36

1

†XMSD

101406

13

10 5/8

14

17 3/8

8 3/8

2 3/4

3&6

55

1 1/2

†XMSH

121808

15 3/4

14 1/8

17

22 1/4

10 3/4

3 1/2

3&6

105

2 1/2

†XMSQ

183610

21 3/4

29

23 3/4

40 7/8

14 7/8

4 5/16

3&6

380

3

$ *† XMRSC

101406

10 5/8

13

18

13 3/8

8 3/8

2 1/4

3&5

55

1

$ *† XMRSF

121206

8 5/8

15 3/4

17

16 1/4

8 15/16

3

3&6

85

1 1/2

$ *† XMRSO

181808

13

21 3/4

23 3/4

22 7/16

12 7/16

3 7/8

3&6

190

2 1/2

Standard conduit openings at locations 1 and 2, control circuit opening 3/4” NPT at locations shown in
column “G”. Each housing has one 1/2” NPT top & bottom for breather and drain.
*

Mounting feet on top and bottom.

†

No breaker handle furnished.

$

Use view “B” for mounting dimensions.

265
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

8C–6

Enclosure

Nom.
Inside
Dim.

15599 Sec.7 12/9/01 11:14 AM Page 229

7A–1

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

FS Control3 Specifications

FS Control3
We named this line of control stations FS Control3
because we offer it in three different material types –
carbon steel, stainless steel and fiberglass – to meet
your control station needs. Each material type has certain

properties and characteristics that make it well-suited for
certain applications. If you would like assistance in
determining which enclosure type best fits your
application, please consult our engineering department.

Features and Benefits

Compliances

• The normally open/normally closed factory sealed contact
block is rated both NEMA A600 and NEMA Q300

X2CS, X2SS, and X2FG Series:
UL Standard 698, 1604 and 2279
Canadian Standards Association C22.2 No. 213-M1987
NEC Class I, Division 2, Groups ABCD; Class II, Division 2,
Groups FG; Class III
NEC Class I, Zone 2, Group IIC

• Electrical ratings for pilot lights range between 6 volts
and 480 volts
• Carbon steel, stainless steel and fiberglass control station
enclosure types available in one- through four-hole
arrangements to accommodate a wide variety of system
needs. Other configurations are available - consult factory

X2CS Series:
NEMA Type 3, 3R, 7ABCD (Division 2), 12 and 13, 4

• Conduit hub entries available in 1/2", 3/4" and 1" sizes
either dead-end or feed through

X2FG and X2SS Series:
NEMA Type 3, 3R, 4, 4X, 7ABCD (Division 2), 12, 13

• Broad new line of 30mm industrial pilot lights,
pushbuttons and selector switches allows thousands of
possible control station configurations

Factory Sealed Contact Block:
Underwriters Laboratories – UL698, UL 1203, UL1604 and
UL2279
Class I, Division 1, Groups ABCD
Class I, Zone 1, Group IIC
Class I, Division 2, Groups ABCD
Class I, Zone 2, Group IIC
Canadian Standards Association C22.2 No. 213-M1987
Class I, Div. 2, Groups BCD

• High-quality legend plates permit easy identification of
device function

Material/Finish
• Enclosures:
X2CS – Made from 14 ga. cold-rolled steel with
continuously welded seams ground to a smooth finish.
Each X2CS enclosure comes complete with a grounding
stud and wall mounting back brackets welded to the
outside top and bottom. Phosphatized and finished inside
and out with ANSI/ASA 61 gray polyester powder coating.

Pilot Lights:
Listed Underwriters Laboratories:
Class I, Division 2, Groups ABCD

X2SS – Made from 14 ga. Type 304 stainless steel with
continuously welded seams ground to a smooth finish.
Each X2SS comes complete with a grounding stud and
wall mounting brackets welded to the outside top and
bottom. Finished with #4 brush.
X2FG – Made from compression-molded, fiberglassreinforced polyester. Each X2FG comes complete with a
grounding strap and optional mounting brackets can be
provided. Molded standard machine tool gray.

Certifications
LISTED

X2CS Series:
Type 12, 4

• Industrial Pilot Device Bodies: PBT Polyester
• Industrial Pilot Device Caps: PBT Polyester

X2FG and X2SS Series:
Type 3, 4X, 12 and 13

• Industrial Pilot Device Clamp Rings: Polyester (standard)
or aluminum

Application
• For installation in Division 2 areas of chemical and petrochemical plants, refineries and other process industries
where flammable vapors, gases or combustible dust may
be present due to accidental or abnormal operation

LISTED

• For use with Adalet 30mm pushbuttons, selector
switches and pilot lights to provide circuit/motor control
and/or electrical status indication
LISTED

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

X2CS, X2SS, and X2FG Series:
Listed Underwriters Laboratories:
Class I, Division 2, Groups BCD; Class I, Zone 2, Group IIB+H2;
Class II, Division 2, Groups FG;

Factory Sealed Contact Block:
Listed Underwriters Laboratories:
Class I, Division 2, Groups BCD
Class I, Zone 2, Group IIB+H2
Certified Canadian Standards Association Class I, Div. 2,
Groups BCD
Pilot Lights:
Listed Underwriters Laboratories:
Class I, Division 2, Groups ABCD

229

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 230
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

7A–2

Pushbutton Operators for Use with FS Control3
Pushbutton Operators with Polyester Clamp Ring
Cap Color
Green
Black
Red

Flush Cap

Suffix

Extended Cap

Suffix

Mushroom Cap

Suffix

PBO-FCGN-FS
PBO-FCBK-FS
PBO-FCRD-FS

1TS
2TS
3TS

PBO-XCGN-FS
PBO-XCBK-FS
PBO-XCRD-FS

4TS
5TS
6TS

PBO-MCGN-FS
PBO-MCBK-FS
PBO-MCRD-FS

7TS
8TS
9TS

For additional NO/NC contact block add “/FS” to end of catalog number
For aluminum clamp ring, add “A” after first dash in catalog number.
Example – PBO-AXCRD-FS is red extended cap pushbutton with aluminum clamp ring.
Note: Caps and operating heads are available in a variety of styles and colors –
please consult factory

Maximum Ampere Rating Control Circuit Contacts Type FSBT
AC (A600) 600 VAC max

DC (Q300)

Volts

110

220

440

550

120

240

Make & Interrupting Capacity
Normal Load Break
Continuous Current

60
6
10

30
3
10

15
1.5
10

12
1.2
10

.55
.55
2.5

.27
.27
2.5

Catalog No.

FSBT

One Normally Open and One Normally Closed.

Illuminated Pushbuttons Unit Complete Less Cap1
Type

Volts

Transformer 50/60 Hz

Full Voltage Type

Neon Type

2

Incandescent

LED Resistor Type

4

Dual Input Remote Test

Catalog Number

Suffix

AC
AC
AC
AC 3

TFLU120FS
TFLU240FS
TFLU480FS
TFLU277FS

10TS
11TS
12TS
13TS

6 AC/DC
12 AC/DC
24 AC/DC
120 AC/DC

FVLU6FS
FVLU12FS
FVLU24FS
FVLU120FS

14TS
15TS
16TS
17TS

120 AC/DC
240 AC/DC
480 AC/DC

FVLU120NFS
FVLU240NFS
FVLU480NFS

18TS
19TS
20TS

120 AC/DC
240 AC/DC

RLU120IFS
RLU240IFS

21TS
22TS

120 AC/DC
240 AC/DC

RLU120LFS
RLU240LFS

23TS
24TS

6 AC/DC
12 AC/DC
24 AC/DC
120 AC/DC
240 AC/DC

RTLU6FS
RTLU12FS
RTLU24FS
RTLU120FS
RTLU240FS

25TS
26TS
27TS
28TS
29TS

120
240
480
277

Color Caps for Illuminated
Pushbuttons 5
Color Cap with Polyester Clamp Ring
Color
Amber
Blue
Clear
Green
Red
White

Catalog Number

Suffix

IPBCAR
IPBCBE
IPBCCR
IPBCGN
IPBCRD
IPBCWE

30TS
31TS
32TS
33TS
34TS
35TS

For aluminum clamp ring, add “A” prefix to
color cap catalog number. Example – AIPBCBE
is blue color cap for illuminated pushbutton
with aluminum clamp ring.

Footnotes
1 To order as an assembled illuminated
pushbutton with color cap, add color cap
catalog number to the end of illuminated
pushbutton catalog number.
Example – TFLU120FS-IPBCRD would be
complete illuminated pushbutton with red cap.

2 Neon lights are available with red or green
lamps. Add suffix letter “R” or “G”
respectively to designate color. Use amber,
clear or red cap only for red neon lights; green
or clear cap only for green neon lights.

3 120 Volt incandescent lamps are not
recommended when the unit is subjected to
shock and/or vibration. A transformer, resistor,
neon or LED unit will provide longer lamp life.

4 Specify LED lamp color. Add suffix letter “R”
for red, “G” for green and “Y” for yellow
(amber). Use amber, clear or red cap only for
red lights; green or clear cap only for green
lights; red, clear or amber for yellow lights.

5 Catalog numbers are for extended color caps.
For flush guarded color caps, add suffix
“EECR” to the catalog number.

230
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 231

7A–3

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Push-Twist/Push-Pull Operators for Use with FS Control3

2 Position Push-Twist Release
Maintained Operators Non-Illuminated

2 Position Push-Pull
Maintained Operators Non-Illuminated

Maintained In/Maintained Out
Color
Black
Red
Green
Yellow

Maintained In/Maintained Out

Catalog Number

Suffix

Color

PTR-TMCBK-FS
PTR-TMCRD-FS
PTR-TMCGN-FS
PTR-TMCYW-FS

36TS
37TS
38TS
39TS

Black
Red
Green
Yellow

Catalog Number

Suffix

PBO-PPMCBK-FS
PBO-PPMCRD-FS
PBO-PPMCGN-FS
PBO-PPMCYW-FS

40TS
41TS
42TS
43TS

For aluminum clamp ring, add “A” after first dash in catalog number.
Example – PTR-ATMCGN-FS is 2 position push-twist release operator with
green cap and aluminum clamp ring.

For aluminum clamp ring, add “A” after first dash in catalog number.
Example – PBO-APPMCYW-FS is 2 position push-pull operator with yellow
cap and aluminum clamp ring.

Note: For additional NO/NC contact block add “/FS” to end of
catalog number.

Note: For additional NO/NC contact block add “/FS” to end of
catalog number.

2 Position Push-Pull Release
Maintained Operators Illuminated
Maintained In/Maintained Out
Type
Transformer 60/50 Hz

Full Voltage

Incandescent Resistor

Volts

Catalog Number

Suffix

TFPPM120-IMCRD-FS
TFPPM240-IMCRD-FS
TFPPM480-IMCRD-FS
TFPPM600-IMCRD-FS

44TS
45TS
46TS
47TS

6 AC/DC
12 AC/DC
24 AC/DC
120 AC/DC
120 AC/DC Neon

FVPPM6-IMCRD-FS
FVPPM12-IMCRD-FS
FVPPM24-IMCRD-FS
FVPPM120-IMCRD-FS
FVPPM120NR-IMCRD-FS

48TS
49TS
50TS
51TS
52TS

120 AC/DC
240 AC/DC

RLPPM120-IMCRD-FS
RLPPM240-IMCRD-FS

53TS
54TS

120
240
480
600

AC
AC
AC
AC

For aluminum clamp ring, add “A” after first dash in catalog number.
Example – FVPPM6-AIMCRD-FS is full voltage 2 position push-pull release illuminated operator
with aluminum clamp ring.
Note: Standard color cap on 2 position push-pull illuminated operator is red. Additional
color caps are available – please consult factory.

231
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 232
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

7A–4

Selector Switch Units for Use with FS Control3
(STANDARD)
MOUNTING
POSITION A

MOUNTING
POSITION B
CONTACT BLOCK SHOWN
MOUNTED IN POSITION B

VIEWED FROM BACK

2 Position Selector Switch Units Assembled with Polyester Clamp Ring (partial listing)1
Mounting
Position

Contact
Symbol

A &B

Handle Position
Left / Right
O=Open, X=Closed

O X
X O

Type of Operator

Maintained Position

Suffix

Spring Return –
Right to Left

Suffix

Spring Return –
2
Left to Right

Suffix

Standard

SS02-SHWE-FS

55TS

SRORL-SHWE-FS

60TS

SROLR-SHWE-FS

63TS

Lever

SS02-SLWE-FS

56TS

SRORL-SLWE-FS

61TS

SROLR-SLWE-FS

64TS

Key Locking Pos
Left
Right
Both

K0SS2-KL-FS
K0SS2-KR-FS
K0SS2-KLR-FS

57TS
58TS
59TS

KOSRRL-KLFS
—
—

62TS

—
—
—

For aluminum clamp ring on standard or lever, add “A” after first dash in catalog number. Example – SS02-ASHWE-FS is standard 2 position selector switch unit
maintained position with aluminum clamp ring. For aluminum clamp ring on key, add “A” to beginning of catalog number. Example – AKOSS2-KL-FS is 2 position
key selector switch key locking left with aluminum clamp ring. Optional contact sequences available upon request. Contact block mounted standard in “A”
position. To order additional contact block for “B” mounting position, add “/FS” to the end of the catalog number.

3 Position Selector Switch Units Assembled with Polyester Clamp Ring (partial listing)1
Mounting
Position

Contact
Symbol

Handle Position
Left /Center/Right
O=Open, X=Closed

X O O
O X O

A

O O X
O X O

B

Spring Return –
Left to Center

Suffix

Spring Return –
Right to Center

Maintained Position

Suffix

Standard

SSO3-SHWE-FS

65TS

SRORLC-SHWE-FS 73TS

SRORC-SHWE-FS 81TS SROLRC-SHWE-FS

89TS

Lever

SS03-SLWE-FS

66TS

SRORLC-SLWE-FS 74TS

SRORC-SLWE-FS 82TS SROLRC-SLWE-FS

90TS

Key Locking Pos
Left
Right
Both

K0SS3-KL-FS
K0SS3-KR-FS
K0SS3-KC-FS

67TS
68TS
69TS

KOSRLC-KL-FS
KOSRLC-KR-FS
KOSRLC-KC-FS

75TS
76TS
77TS

Key Locking Pos
Left & Right
Left & Center
Right & Center

KOSS3-KLR-FS
KOSS3-KLC-FS
KOSS3-KRC-FS

70TS
71TS
72TS

KOSRLC-KLR-FS
KOSRLC-KLC-FS
KOSRLC-KRC-FS

78TS
79TS
80TS

KOSRRC-KL-FS
KOSRRC-KR-FS
KOSRRC-KC-FS

Suffix

Spring Return –
Either to Center

Type of Operator

83TS
84TS
85TS

KOSRLRC-KL-FS
KOSRLRC-KR-FS
KOSRLRC-KC-FS

KOSRRC-KLR-FS 86TS KOSRLRC-KLR-FS
KOSRRC-KLC-FS 87TS KOSRLRC-KLC-FS
KOSRRC-KRC-FS 88TS KOSRLRC-KRC-FS

Suffix

91TS
92TS
93TS

94TS
95TS
96TS

For aluminum clamp ring on standard or lever, add “A” after first dash in catalog number. Example – SSO3-ASLWE-FS is lever 3 position selector switch unit
maintained position with aluminum clamp ring. For aluminum clamp ring on key, add “A” to beginning of catalog number. Example – AKOSS3-KLR-FS is 3
position key selector switch key locking left and right with aluminum clamp ring. Optional contact sequences available upon request. Specific key removable
positions are available – consult factory. Contact block mounted standard in “A” position. To order additional contact block for “B” mounting position, add “/FS”
to the end of the catalog number.

Footnotes
1 Catalog numbers for standard and lever
operators identify black operators with white
color insert. Consult factory for other available
colors.

2 Spring Return Left to Right uses a reverse cam
and the contact block selection is the opposite
as shown as standard.

232
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 233

7A–5

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Pilot Lights for Use with FS Control3

Standard Pilot Lights Unit Complete Less Cap
Type

Volts

Catalog Number

Suffix

TFLU120
TFLU240
TFLU480
TFLU277

97TS
98TS
99TS
100TS

FVLU6
FVLU12
FVLU24
FVLU120

101TS
102TS
103TS
104TS

120 AC/DC
240 AC/DC
480 AC/DC

FVLU120N
FVLU240N
FVLU480N

105TS
106TS
107TS

120 AC/DC
240 AC/DC

RLU120I
RLU240I

108TS
109TS

120 AC/DC
240 AC/DC

RLU120L
RLU240L

110TS
111TS

120 AC/DC
240 AC/DC

RTLU120
RTLU240

112TS
113TS

Transformer 50/60 Hz

Full Voltage Type

Neon Type

AC
AC
AC
AC

6 AC/DC
12 AC/DC
24 AC/DC
120 AC/DC 2

1

Incandescent

LED Resistor Type

120
240
480
277

3

Dual Input Remote Test

Footnotes

Color Cap with Polyester Clamp Ring
Color

Catalog Number

Suffix

PLLAR
PLLBE
PLLCR
PLLGN
PLLRD
PLLWE

126TS
127TS
128TS
129TS
130TS
131TS

Amber
Blue
Clear
Green
Red
White

For aluminum clamp ring, add “A” prefix to
color cap catalog number. Example – APLLBE
is blue color cap for standard pilot light with
aluminum clamp ring.

LED Lamps

1 Neon lights are available with red or green

shock and/or vibration. A transformer, resistor,
neon or LED unit will provide longer lamp life.

lamps. Add suffix letter “R” or “G”
respectively to designate color. Use amber,
clear or red cap only for red neon lights; green
or clear cap only for green neon lights.

3 Specify LED lamp color. Add suffix letter “R”
for red, “G” for green and “Y” for yellow
(amber). Use amber, clear or red cap only for
red lights; green or clear cap only for green
lights; red, clear or amber for yellow lights.

2 120 Volt incandescent lamps are not
recommended when the unit is subjected to

Push-to-Test Pilot Lights Unit Complete Less Cap
Type
Transformer 50/60 Hz

Full Voltage Type

Neon Type

Color Caps
for Standard Pilot Lights

1

Incandescent Resistor Type
LED Resistor Type

3

Volts

Catalog Number

Suffix

120 AC
240 AC
480 AC

TFPTT120FS
TFPTT240FS
TFPTT480FS

114TS
115TS
116TS

6 AC/DC
12 AC/DC
24 AC/DC
2
120 AC/DC

FVPTT6FS
FVPTT12FS
FVPTT24FS
FVPTT120FS

117TS
118TS
119TS
120TS

120 AC/DC
240 AC/DC
480 AC/DC

FVPTT120NFS
FVPTT240NFS
FVPTT480NFS

121TS
122TS
123TS

120 AC/DC

RLPTT120FS

124TS

120 AC/DC

RLPTT120LFS

125TS

Footnotes
1 Neon lights are available with red or green
lamps. Add suffix letter “R” or “G”
respectively to designate color. Use amber,
clear or red cap only for red neon lights; green
or clear cap only for green neon lights.

2 120 Volt incandescent lamps are not
recommended when the unit is subjected to
shock and/or vibration. A transformer, resistor,
neon or LED unit will provide longer lamp life.

3 Specify LED lamp color. Add suffix letter “R”
for red, “G” for green and “Y” for yellow
(amber). Use amber, clear or red cap only for
red lights; green or clear cap only for green
lights; red, clear or amber for yellow lights.

4 Catalog numbers are for extended color caps.
For flush guarded color caps, add suffix
“EECR” to the catalog number.

Transformer lights and full voltage 6, 12 and
24 volt lights can be provided with solid state
long life LED lamps in place of the standard
incandescent lamps. Adalet’s LED lamps are
in a miniature bayonet base for direct
interchangeability and feature an ultra bright
4 LED cluster with light output comparable to
a standard type 755 incandescent lamp. The
4 LEDs are built into two circuits for
redundancy and include internal current
limiting resistors. Lamps are available in red,
green, and yellow.

How to Order
Add the letter “L” plus the first letter of the
color to the light catalog number.

Example: Catalog number TFLU120LR
would be a transformer light with red LED
lamp.

Color Caps
for Push-to-Test Pilot Lights

4

Color Cap with Polyester Clamp Ring
Color
Amber
Blue
Clear
Green
Red
White

Catalog Number Suffix
IPBCAR
IPBCBE
IPBCCR
IPBCGN
IPBCRD
IPBCWE

30TS
31TS
32TS
33TS
34TS
35TS

For aluminum clamp ring, add “A” prefix to
color cap catalog number. Example – AIPBCBE
is blue color cap for push-to-test pilot light with
aluminum clamp ring.

233
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 234
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

7A–6

Legend Plates for Use with FS Control3

Standard Legend Plates
Description

Catalog Number
Prefix

Standard
Narrow
Short

LP
LPN
LPS

Height (inches)

Width (inches)

Characters
Per Line

Number of Lines

2
2

2
1 3/4
2

16
16
16

2
2
2

1 3/4

Legend plates are available in the three styles listed above plus the IEC standard emergency
legend plate shown to the right. Standard is black background with white letters except -05
and -28 which are red background with white letters. Other colors are available – consult
factory. Plates with special legends are available – consult factory.

Standard Legends
Pushbuttons and Lights

2 Position Selector

3 Position Selector

Catalog No.
Suffix

Legend Left

Legend Right

Catalog No.
Suffix

Legend Left

Legend Center

Legend Right

Catalog No.
Suffix

01
02
03
04

Auto
Auto
Down
Fast

Hand
Manual
Up
Slow

50
68
51
63

Down
Fwd
Fwd
Hand

Off
Auto
Off
Off

Up
Rev
Rev
Auto

80
81
82
83

05

Fwd

Rev

52

Manual

Off

Auto

84

Fast
Forward
Hand
Inch
Jog

06
07
08
09
10

Hand
Inch
Manual
Off
On

Auto
Run
Auto
On
Off

53
54
55
56
57

Off
Off
Off
1
1

Run
Start
1
Off
2

Start
Run
2
2
3

89
85
86
87
88

Manual
Motor Run
Off
On
Overload

11
26
12
13
27

Open
Push On
Pull Start
Push Off
Push to Stop

Close
Push Off
Push Stop
Pull On
Pull to Start

58
64
65
66
67

Open
Power Off
Power On
Push-to-Reset
Push-to-Test

14
15
16
30
17

Rev
Run
Slow
Start
Stop

Fwd
Jog
Fast
Stop
Start

59
60
69
61
62

Reset
Reverse
Run
Slow
Start

18
19
20
21
22

Stop
Stop (red)
Test
Trip
Up

23
28
24
29
25

Legend
Auto
Close
Down
Emergency
Stop
Emergency
Stop (red)

Options
• Laser engraving on legend plates
• Legend plates available in white, red and aluminum in addition to standard black
• Round, yellow legend plates.

234
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 235

7A–7

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

FS Control3 Dimensions

7/32 DIA.
MTG.
HOLES

4 7/8
4 5/16
C

6 1/16
5 1/2

B

C
F

B

.201 DIA.
MTG. HOLES

K

K

G
A

G

A

6 1/8
6 7/16

J

5
5 5/16

J

STAINLESS STEEL & CARBON STEEL

F

FIBERGLASS

Dimensions Stainless Steel (X2SS) & Carbon Steel (X2CS)
Body
Style

Outside
Dimensions

Mounting
Dimensions

1/2" Hubs

3/4" Hubs

1" Hubs

A

B

C

F

G

J

K

J

K

J

K

1 Hole

4 5/16

4 5/16

5

3 1/8

4 1/2

13/16

1 1/2

7/8

1 1/2

1

1 1/2

2 Holes

6 5/16

4 5/16

5

3 1/8

6 1/2

13/16

1 1/2

7/8

1 1/2

1

1 1/2

3 Holes

8 5/16

4 5/16

5

3 1/8

8 1/2

13/16

1 1/2

7/8

1 1/2

1

1 1/2

4 Holes

10 5/16

4 5/16

5

3 1/8

10 1/2

13/16

1 1/2

7/8

1 1/2

1

1 1/2

Dimensions Fiberglass (X2FG)
Body
Style

Outside
Dimensions

Mounting
Dimensions

1/2" Hubs

3/4" Hubs

1" Hubs

A

B

C

F

G

J

K

J

K

J

K

1 Hole

6 5/8

3 13/16

3 7/8

2 15/16

4 7/8

13/16

1 1/2

7/8

1 1/2

1

1 1/2

2 Holes

6 5/8

3 13/16

3 7/8

2 15/16

4 7/8

13/16

1 1/2

7/8

1 1/2

1

1 1/2

3 Holes

8 7/8

3 13/16

3 7/8

2 15/16

7 1/8

13/16

1 1/2

7/8

1 1/2

1

1 1/2

4 Holes

11 1/8

3 13/16

3 7/8

2 15/16

9 3/8

13/16

1 1/2

7/8

1 1/2

1

1 1/2

235
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 236
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

7A–8

FS Control3 Catalog Logic

Catalog Logic/Example

Enclosure Type

Cover
Holes Entry Hub Size

Industrial
Industrial Pilot
Pilot Devices
Devies

TOP

BOTTOM

X2CS - Carbon Steel
X2SS - Stainless Steel
X2FG - Fiberglass
1234-

1 Hole
2 Holes
3 Holes
4 Holes

T - Top Feed
B - Bottom Feed
F - Feed Through

Order pilot devices utilizing the suffix number from
the tables on pages 7A–2 to 7A–5. (Also, remember
to select legend plates from page 7A–6.)

2 - 1/2" Hub
3 - 3/4" Hub
4 - 1" Hub

The above example is a carbon steel control station, 4 holes, with feed through and 1/2" hub.
Hubs included.

236
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 249
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Circuit Breaker Lighting & Power Distribution Panel Boards
Explosionproof and Dust-Ignitionproof

8A–1

ENCLOSURES: The housings are copper-free cast aluminum
alloy. The housings are Adalet XCE series and have precision
ground cover and body joints.
The design offers sufficient gutter space on sides to allow
through wiring and easy lug connection. All enclosures are
furnished with hinges, stainless steel cover bolts and are
provided with Nema 4 gasketing. All covers are removable for
clear access to breakers and gutter space. The compact design
of rectangular housings permits close grouping on switch racks
and other structures. No additional space is required for cover
removal except from the front.
MECHANICAL FEATURES: The front mounted power panel
and lighting panel branch breaker handles can be padlocked
either in “off” or “on” position. All breaker handles are spring
loaded allowing closing of the cover with breaker toggle in any
position. Operating handle shafts have “V” ring gaskets for
watertight application.
ELECTRICAL FEATURES: Breaker panel chassis, featuring
bolt-on circuit breakers, are made by Cutler-Hammer. Chassis for
the power distribution XPB2 series provides 480V/277 volt
connections. The circuit breakers are rated for 480 volt max.
The Adalet lighting panel board XPB1 series offers 15 through
60 amps, 120, 240 volt bolt on circuit breakers with ground and
insulated neutral bars as standard features. The Cutler-Hammer
Industrial Ground Fault Circuit Protectors (GFCI 5mA, GFEPD
30mA) and switching neutral breakers are available as optional
features.

Compliances:

Approvals:

UL, cUL Classified Enclosure
UL Standard 1203
CSA Standard C22.2 No. 30

Enclosure Certifications

Class I, Groups B, C, D
Class II, Groups E, F, G
Class III
NEMA 4, 7, 9

E81696

249
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 250
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Circuit Breaker Lighting Panel Boards
Explosionproof and Dust-Ignitionproof
CLASS I, GROUP B, C, D; CLASS II, GROUPS E, F & G;
CLASS III, NEMA 4, 7 & 9
8A–2

Explosionproof circuit breaker lighting panelboards use cast aluminum alloy housings with hinged cover. External operating handles
can be padlocked in “on” or “off” position. Incorporates Cutler-Hammer bolt-on breakers @ 240 volt max. Top feed standard.

BACK FED MAIN BREAKER PANELBOARDS
120/240 VOLT, 1 PHASE 3 WIRE, SOLID NEUTRAL
CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES
10,000 AMPERE INTERRUPTING CAPACITY (SYM.)
Number of
Avail. Breakers

MLO / BFD

Catalog
Number

Main Breaker
Amperes

Box
Size

10

BFD

XPB1-121 B1

100

A

16

BFD

XPB1-181 B1

100

A

22

BFD

XPB1-241 B1

100

B

BACK FED MAIN BREAKER PANELBOARDS
120/208 VOLT, 3 PHASE 4 WIRE, SOLID NEUTRAL
CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES
10,000 AMPERE INTERRUPTING CAPACITY (SYM.)
Number of
Avail. Breakers

Catalog
Number

MLO / BFD

Main Breaker
Amperes

Box
Size

9

BFD

XPB1-123 B1

100

A

15

BFD

XPB1-183 B1

100

A

21

BFD

XPB1-243 B1

100

B

250
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 251
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Circuit Breaker Lighting Panel Boards
Explosionproof and Dust-Ignitionproof

8A–3

MAIN LUG ONLY PANELBOARDS
1 PHASE 3 WIRE 120/240 VOLT TOP FEED MAIN LUG ONLY
CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES
10,000 AMPERE INTERRUPTING CAPACITY (SYM)
Number of
Breakers

Catalog
Number

Main Lug
Amperes

Box
Size

12

XPB1-121L1

100

A

18

XPB1-181L1

100

A

24

XPB1-241L1

100

B

24

XPB1-241L2

225

B

30

XPB1-301L2

225

D

36

XPB1-361L2

225

D

MAIN LUG ONLY PANELBOARDS
3 PHASE 4 WIRE 120/208 VOLT TOP FEED MAIN LUG ONLY
CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES
10,000 AMPERE INTERRUPTING CAPACITY (SYM)
Number of
Breakers

Catalog
Number

Main Lug
Amperes

Box
Size

12

XPB1-123L1

100

A

18

XPB1-183L1

100

A

24

XPB1-243L1

100

B

24

XPB1-243L2

225

B

30

XPB1-303L2

225

D

36

XPB1-363L2

225

D

How to order:
A) Specify catalog number and voltage
B) Number of operator handles, single pole, two pole and
three pole as required.
C) Circuit breakers, number of poles and ampere rating.
Unused spaces will be plugged. Top feed standard.

251
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 252
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Circuit Breaker Lighting Panel Boards
Explosionproof and Dust-Ignitionproof
MODIFICATIONS AND OPTIONS
8A–4

Branch Breakers – Operating Handles – Components
CIRCUIT BREAKER OPERATOR HANDLES INSTALLED IN XPB1 PANEL BOARDS
Catalog
Number

Weight
Each

Description

XPB1-H1

For single pole BAB breakers

1/4 lb.

XPB1-H2

For two pole BAB breakers

1/4 lb.

XPB1-H3

For three pole BAB breakers

1/4 lb.

XPB1-GL

For single pole GFI ground

1/4 lb.

XPB1-GR

Fault breakers (specify left or right side)

1/4 lb.

BRANCH CIRCUIT BREAKERS INSTALLED IN XPB1 PANEL BOARDS:
BOLT-ON THERMAL MAGNETIC BREAKERS 120/240 VOLT 10,000 AMPERE I.C.
Catalog No.

Description

XPB1-1*

1 pole breaker (available in 10-70 amp)

XPB1-2*

2 pole breaker (available in 10-100 amp)

XPB1-3*

3 pole breaker (available in 10-100 amp)

*Add ampere rating of the branch breaker when ordering.
GROUND FAULT CIRCUIT PROTECTORS
BOLT-ON SWITCHING NEUTRAL BREAKERS
120/240 VOLT 10,000 AMPERE I.C.

120/240 VOLT 10,000 AMPERE I.C. STD.
22,000 AMPERE I.C. OPTIONAL
Catalog No.

Description

Catalog No.

Description

XPB1-1GFCI*

1 pole GFCI Breaker 5 MA Sensitivity

XPB1-N1*

1 pole switching to neutral
Requires two spaces (available in 15-30 amp)
2 pole switching to neutral
Requires three spaces (available in 15-30 amp)

XPB1-2GFCI*

2 pole GFCI Breaker 5 MA Sensitivity

XPB1-1GFEPD*

1 pole GFCI Breaker 30 MA Sensitivity

XPB1-2GFEPD*

2 pole GFCI Breaker 30 MA Sensitivity

XPB1-N2*

*Add ampere rating of the branch breaker when ordering

Above Available with special application Bell Alarm or Auxiliary Switch.

*Add ampere rating of the branch breaker when ordering

OPTIONAL FEATURES
MODIFICATIONS:
Suffix
Letter
E
EE
L1
L2
NP
CU
Q

Description
Breather Drain (not type 4)
Breather and drain (not type 4)
Epoxy Coating Outside
Epoxy Coating Inside/Outside
Lamacoid Nameplate
Copper Bus Bar
Quad-Lead Bolts

252
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 253
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Circuit Breaker Power Distribution Panel Boards
Explosionproof and Dust-Ignitionproof

Explosionproof circuit breaker power panelboards use cast aluminum alloy housings with hinged cover. External operating handles
can be padlocked in “on” or “off” positions. Incorporates Cutler-Hammer bolt-on breakers @ 480 volt max. Top feed standard.

BACK FED MAIN BREAKER PANELBOARDS
277/480 VOLT, 3 PHASE 4 WIRE, SOLID NEUTRAL
CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES
14,000 AMPERE INTERRUPTING CAPACITY (SYM.)
Number of
Avail. Breakers

Catalog
Number

MLO / BFD

Main Breaker
Amperes

Box
Size

9

BFD

XPB2-123B1

100

A

15

BFD

XPB2-183B1

100

A

21

BFD

XPB2-243B1

100

B

100 ampere main lugs conductor size #12 -1/0 CU/AL.
225 ampere main lugs conductor size #6-300 MCM CU/AL.
How to order:
A) Specify catalog number and voltage
B) Number of operator handles, single pole, two pole and three pole as
required.
C) Circuit breakers, number of poles and ampere rating
Unused spaces will be plugged. Top feed standard.

MAIN LUG ONLY PANELBOARDS
277/480 VOLT, 3 PHASE 4 WIRE
CHASSIS WITHOUT BRANCH BREAKERS OR OPERATING HANDLES
14,000 AMPERES INTERRUPTING CAPACITY (SYM)

Compliances:
UL, cUL Classified Enclosure
UL Standard 1203
CSA Standard C22.2 No. 30
Class I, Groups B, C, D
Class II, Groups E, F, G
NEMA 4, 7, 9

Number of
Breakers

Catalog
Number

Main Lug
Amperes

Box
Size

12

XPB2-123L1

100

A

18

XPB2-183L1

100

A

24

XPB2-243L1

100

B

24

XPB2-243L2

225

B

Approvals:

30

XPB2-303L2

225

D

Enclosure Certifications

36

XPB2-363L2

225

D

How to order: Specify catalog number, operator handles and
circuit breakers as separate items. Single pole breakers use 1
handle space, 1 handle. 2 pole, 2 spaces, 1 handle. 3 pole, 3
spaces, 1 handle. Unused spaces will be plugged. Top feed
standard.

E81696

253
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

8A–5

CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; CLASS II, NEMA 4, 7 & 9

15599 Sec.8 12/9/01 11:17 AM Page 254
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Circuit Breaker Power Distribution Panel Boards
Explosionproof and Dust-Ignitionproof
MODIFICATIONS AND OPTIONS
8A–6

Branch Breakers – Operating Handles – Components
BREAKER OPERATOR HANDLES INSTALLED IN XPB2 PANEL BOARDS
Catalog
Number
XPB2-H1

Description

Weight
Each

For 1, 2 or 3-pole GHB breaker

1/4 lb.

BRANCH CIRCUIT BREAKERS INSTALLED IN XPB2 PANEL BOARDS:
BOLT-ON THERMAL MAGNETIC BREAKERS
Catalog No.
XPB2-1*

Description
1 pole GHB breaker (available in 15-100 amp)
277 volt A.C.
2 pole GHB breaker (available in 15-100 amp)
480 volt A.C.
3 pole GHB breaker (available in 15-100 amp)
480 volt A.C.

XPB2-2*
XPB2-3*

*Add ampere rating of the branch breaker when ordering.

OPTIONAL FEATURES
MODIFICATIONS:
Suffix
Letter
E
EE
L1
L2
NP
CU
Q

Description
Breather Drain (not type 4)
Breather and drain (not type 4)
Epoxy Coating Outside
Epoxy Coating Inside/Outside
Lamacoid Nameplate
Copper Bus Bar
Quad-Lead Bolts

254
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.8 12/9/01 11:17 AM Page 255
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Circuit Breaker Lighting and Distribution Panel Boards
Explosionproof and Dust-Ignitionproof
ENCLOSURE DIMENSIONS & DATA SHEET

A

B

1/2" NPT

Top

(1)

—

(1)

—

Side

—

(2)

—

Bottom

(1)

(8)

—

—
—

Top

(1)

—

(1)

—

—

(2)

—

—

Bottom

(1)

(8)

—

—

Top

(1)

—

—

(1)
—

Side

—

(2)

—

Bottom

(1)

(10)

—

—

Top

(1)

—

—

(1)

Side

—

(2)

—

—

Bottom

(1)

(10)

—

—

D

Internal
Dimensions

(A) Mtg
Width

(B) Mtg
Height

(C) Overall
Width

3" NPT

Side

C

Box
Size

Conduit Entries
1" NPT
2" NPT

(D) Overall
Height

(E) Overall
Depth

8A–7

CONDUIT ENTRIES
Enclosure
Size

Mtg. Bolt
Size

A

161606

19 3/4

11

20 7/8

20 7/8

11

5/8

B

162406

19 3/4

18 3/8

20 7/8

28 7/8

11 1/2

5/8

C

162806

19 3/4

22 1/2

20 1/2

32 1/2

10 3/4

5/8

D

163406

19 3/4

27

20 1/2

38 1/2

10 3/4

5/8

Box Size

F

G

H

J

K

L

M

N

A

1 1/4

3 3/4

4 3/4

2 3/8

3 5/8

1

3 1/2

2 1/2

Weight lbs.
160

B

1 1/4

3 3/4

4 3/4

2 3/8

3 5/8

3

5

2 1/2

220

C

2

4

4 15/16

2 15/16

4 3/16

5

7

2 1/2

235

D

2

4

4 15/16

2 15/16

4 3/16

8

11

2 1/2

285

255
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 271
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Pilot Devices

CLASS I, GROUPS B, C & D; CLASS II, GROUPS E, F & G

APPLICATIONS

9A–1

Adalet operators are for use in control circuits functioning in
environments containing hazardous gases, vapors or dusts.
These heavy duty pilot lights, pushbuttons and selector
switches are suitable for use in Class I, Groups B, C & D
hazardous gas; Class II, Groups E, F & G dust atmospheres.
Most are suitable for weather-tight (N4) applications.

FEATURES:
• Most operators are suitable for NEMA 3, 4, NEMA 7, 9, raintight, water-tight in hazardous environments.
• Two lengths available for either surface or panel mount.
• Knurled caps are standard with black anodized finish.
• Optional: specify color-coding of operator caps (no additional
cost).
• Pilot light transformers available for 240 volts.
• Special length pilot light wiring leads available.
• Screw terminals available suffix T.
• Coated to minimize corrosion and provide for ease of
installation.
• Operators are 3/4” NPSM standard.
• Stainless steel shafts are standard (except pilot light
pushbutton operator).
Consult factory for UL/CSA certification availability.
Compliances: NEC Class I, Groups B, C & D - Class II, Groups
E, F, G
UL Standard 698 - Standard C22.2 No. 30

Notes:
Where reference is made to Class I and Class II hazardous locations, the
equipment is suitable for use in both Division 1 and Division 2 hazardous
locations.

The Adalet engineering department is available to assist in the selection of custom explosionproof housings for your products.
271
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 272
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Pilot Lights

CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Explosionproof pilot lights are suitable for panel or surface mount
applications. All pilot lights are of sealed construction and can be relamped
from the front by removal of lens cap.
All pilot lights are made with 3/4” NPSM threads. All pilot lights have 8”
flexible leads, other lengths on special order, or screw terminals.
All lens caps are black anodized aluminum finish. For color coding we will
furnish at no additional charge the following color combinations: lens ambercap gold, lens blue-cap blue, lens clear-cap natural aluminum, lens green-cap
green, lens red-cap red, lens white-cap natural aluminum. Specify on orders.

9A–2

Maximum installation thickness 1 15/16” on Long Series, 3/4” on Short
Series.
This standard series of pilot lights is equipped with candelabra base
receptacles and 6 watt 120 volt 6S6 clear 1500 hr. avg. lamps. Also available
with 6, 12, 24, 30, 50, 75 and 135 volt lamps. Specify voltage desired.
Catalog
Number
Long Series

Catalog
Number
Short Series

Weight
Each
Pounds

Description

XLA

XLSA

Amber Lens

1/2

XLB

XLSB

Blue Lens

1/2
1/2

XLC

XLSC

Clear Lens

XLG

XLSG

Green Lens

1/2

XLR

XLSR

Red Lens

1/2

XLW

XLSW

White Lens

1/2

*Add suffix T to P/N for screw terminal

This special series of pilot lights is equipped with slide base receptacles
and 120 volt 5000 hr. avg. lamps with slide base. Also available with 6, 12,
24, 48 and 60 volt lamps. Specify voltage desired.

Legend Plates, see page 9A–18

Catalog
Number
Long Series

Catalog
Number
Short Series

Weight
Each
Pounds

Description

XLAS

XLSAS

Amber Lens

1/2

XLBS

XLSBS

Blue Lens

1/2
1/2

XLCS

XLSCS

Clear Lens

XLGS

XLSGS

Green Lens

1/2

XLRS

XLSRS

Red Lens

1/2

XLSWS

White Lens

1/2

XLWS

*Add suffix T to P/N for screw terminal

2 5/16

Pilot Light Transformers
Catalog
Number

Description

Weight Each
Pounds

XLT 240

240 to 120 volt, 6VA

1

One transformer required for each pilot light. Adapter furnished for
mounting on threaded pilot light stem, or can be mounted to housing as
space requires.
272
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 273
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Pilot Lights
CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Guarded Pilot Lights

Maximum installation thickness 1 15/16” on Long Series (Panel Mount),
3/4” on Short Series (Surface Mount).
This standard series of pilot lights is equipped with candelabra base receptacles
and 6 watt 120 volt 6S6 clear 1500 hr. avg. lamps. Also available with 6, 12, 24,
30, 50, 75 and 135 volt lamps. Specify voltage desired.
Catalog No.
Panel Mount
(Long Series)

Catalog No.
Surface Mount
(Short Series)

Weight
Each
Pounds

Description

XLA-G

XLSA-G

Amber Lens

1/2

XLB-G

XLSB-G

Blue Lens

1/2

XLC-G

XLSC-G

Clear Lens

1/2

XLG-G

XLSG-G

Green Lens

1/2

XLR-G

XLSR-G

Red Lens

1/2

XLW-G

XLSW-G

White Lens

1/2

*Add suffix T to P/N for screw terminal

This special series of pilot lights is equipped with slide base receptacles
and 120 volt 5000 hr. avg. lamps with slide base. Also available with 6, 12,
24, 48 and 60 volt lamps. Specify voltage desired.
Catalog No.
Panel Mount
(Long Series)

Catalog No.
Surface Mount
(Short Series)

Weight
Each
Pounds

Description

XLAS-G

XLSAS-G

Amber Lens

1/2

XLBS-G

XLSBS-G

Blue Lens

1/2

XLCS-G

XLSCS-G

Clear Lens

1/2

XLGS-G

XLSGS-G

Green Lens

1/2

XLRS-G

XLSRS-G

Red Lens

1/2

XLWS-G

XLSWS-G

White Lens

1/2

*Add suffix T to P/N for screw terminal

Replacement Guarded Lens Cap Assembly
Catalog
Number

Description

XLA-GC

Amber Lens

1/8

XLB-GC

Blue Lens

1/8

XLC-GC

Clear Lens

1/8

XLG-GC

Green Lens

1/8

XLR-GC

Red Lens

1/8

XLW-GC

White Lens

1/8

Legend Plates, see page 9A-19.
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

Weight Each
Pounds

273

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

9A–3

Explosionproof pilot lights are suitable for panel or surface mount applications. All
pilot lights are of sealed construction and can be relamped from the front by
removal of lens cap.
All pilot lights are made with 3/4” NPSM threads. All pilot lights have 8” flexible
leads, other lengths on special order, or screw terminals.
All lens caps are black anodized aluminum finish.

15599 Sec.9 12/9/01 11:19 AM Page 274
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Pilot Lights

CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Guarded Pilot LED Lights
LED Advantages:
• 10 Year/100,000 hour service life under normal ambient conditions.
• 1x to 4x more energy efficient.
• Improved resistance to shock and vibration.
• LEDs operate significantly cooler than traditional lamps.
• Ultra bright cluster LED’s

9A–4

Explosionproof pilot LED lights are suitable for panel or surface mount
applications. All candelabra base LED lights can be relamped from the front
by removal of the lens cap.
All pilot LED lights are made with 3/4” NPSM threads. All pilot LED lights
have 8” flexible leads, other lengths on special order, or screw terminal.
Screw terminal available suffix T.
All lens caps are black anodized aluminum finish with clear glass lens.
Maximum installation thickness: 1-15/16” on Panel Mount (Long
Series), 3/4” on Surface Mount (Short Series).
Consult Adalet for the availability of other voltages.

Catalog No.
Panel Mount
(Long Series)

Catalog No.
Surface Mount
(Short Series)

Description

Weight
Each
Pounds

XLRL-G

XLSRL-G

Red

1/2

XLAL-G

XLSAL-G

Amber

1/2

XLGL-G

XLSGL-G

Green

1/2

XLWL-G

XLSWL-G

White

1/2

XLBL-G

XLSBL-G

Blue

1/2

*Add suffix T to P/N for screw terminal

274
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 275
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Pilot Light Push Buttons
CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 7, 9
Indicator Light/Push Button
Push-To-Test Operators

For use with
series BT
contact blocks

Description of operators only

9A–5

All operators are die cast aluminum alloy. The barrels are all 3/4”
NPSM thread. Maximum installation thickness 1 15/16” panel mount,
3/4” surface mount.
Furnished standard with 120 volt slide base lamp. Also available for 6,
12, 24, 28, 48 and 60 volts. Specify when ordering.
For use with BT contact blocks. Contact blocks can be stacked for
multiple circuits. Contact blocks are not included with the operators.
Order from page 9A–20. For NEMA 4 application, add boot and special
legend plate, see page 9A–19.

Weight
Each
Pounds

For Panel Mounting
XLPA

Amber Lens

3/4

XLPB

Blue Lens

3/4

XLPC

Clear Lens

3/4

XLPG

Green Lens

3/4

XLPR

Red Lens

3/4

XLPW

White Lens

3/4

For Surface Mounting
XLPAS

Amber Lens

1/2

XLPBS

Blue Lens

1/2

XLPCS

Clear Lens

1/2

XLPGS

Green Lens

1/2

XLPRS

Red Lens

1/2

XLPWS

White Lens

1/2

Legend Plates, see page 9A–19.

275
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 276
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Push Buttons
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Push Button Operators

9A–6

All operators are die cast aluminum alloy. The barrels are all 3/4”
NPSM thread. Maximum installation thickness 1 3/4” panel mount,
3/4” surface mount.
All operators have black molded nylon buttons. The exposed metal
parts are black anodized aluminum. For color coding we will furnish at
no additional cost the following color combinations: Red buttons with
red metal caps and green buttons with green metal caps. Metal caps
are also available in blue, gold or clear with black buttons. Specify
colors required.
Red Mushroom head buttons are 1 3/4” diameter anodized aluminum.
Also available in black or green.
XHPBPL has padlock attachment on top of cap allowing operator to be
locked with the push button depressed.
For use with BT contact blocks. Contact blocks can be stacked for
multiple circuits. Contact blocks are not included with the operators.
Order from page 9A–20.
XHPPM/XHPPMS require 2" minimum spacing.
For use with
series BT
contact blocks

Description of operators only

Weight
Each
Pounds

XHPB

Panel Mount

1/2

XHPBS

Surface Mount

1/2

XHPBM

Red Mushroom Head, Panel Mount

1/2

XHPBMS

Red Mushroom Head, Surface Mount

1/2

XHPBPL

W/Padlock devices, Panel Mount

3/4

XHPBSPL

W/Padlock devices, Surface Mount

3/4

XHPPM*

Push/Pull switches, Panel Mount

3/4

XHPPMS*

Push/Pull switches, Surface Mount

3/4

Legend Plates, see page 9A–19.
*Type BT1 contact blocks are included
For extremely wet-dirty location applications, XHPB and XHPBS series
are available to be used with protective boots, see page 9A–19.

276
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 277
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Push Buttons
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Push Button Operators
1

1 —4
5
1—
16

1

1

4 —2

3 —4

3

1 —4
3

1 —4

13

1

3—
16

5—
16

Cost effective modular operator body. The barrels are all 3/4” NPSM
thread aluminum. Maximum installation thickness 1 3/4” panel mount,
3/4” surface mount.
All operators have black molded nylon buttons. The exposed metal
parts are black anodized aluminum. For color coding we will furnish at
no additional cost the following color combinations: Red buttons with
red metal caps and green buttons with green metal caps. Metal caps
are also available in blue, gold or clear with black buttons. Specify
colors required.
Red Mushroom head buttons are 1 3/4” diameter anodized aluminum.
Also available in black or green.
XVHPBPL has padlock attachment on top of cap allowing operator to
be locked with the push button depressed.
For use with BT contact blocks. Contact blocks can be stacked for
multiple circuits. Contact blocks are not included with the operators.
Order from page 9A–20.
XVHPPM/XVHPPMS require 2" minimum spacing.

For use with
series BT
contact blocks
3

1 —4
3

1 —4

3

7 EXT.

5 —4

EXT.

Description of operators only

9A–7

1

1 —4

Weight
Each
Pounds

XVHPB

Panel Mount

1/2

XVHPBS

Surface Mount

1/2

XVHPBM

Red Mushroom Head, Panel Mount

1/2

XVHPBMS

Red Mushroom Head, Surface Mount

1/2

XVHPBPL

W/Padlock devices, Panel Mount

3/4

XVHPBSPL

W/Padlock devices, Surface Mount

3/4

XVHPPM*

Push/Pull switches, Panel Mount

3/4

XVHPPMS*

Push/Pull switches, Surface Mount

3/4

Legend Plates, see page 9A–19.
*Type BT1 contact blocks are included
5

1 —8
5

1 —8

1

5—
16

For extremely wet-dirty location applications, XVHPB and XVHPBS
series are available to be used with protective boots, see page 9A–19.
13

3—
16

277
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 278
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Push Buttons
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Dual Push Button Operator or
Maintained Contact Unit
All operators are die cast aluminum alloy. The barrels are all 3/4”
NPSM thread. Maximum installation thickness 1 15/16” panel mount,
3/4” surface mount.
For use with BT contact blocks. Contact blocks can be stacked for
multiple circuits. Contact blocks are not included with XHD operators.
Order from page 9A–20.
5

9A–8

1 —8

1

1 —4

5

1 —8

For use with
series BT
contact blocks

1

1 —4

1
1 —4
1

1 —4
3

3

4—
16

Description of operators only

Weight
Each
Pounds

XHDPB

Panel Mount - momentary*

1/2

XHDPBS

Surface Mount - momentary*

1/2

XHDMC

Maintained Contact, Panel Mount

1/2

XHDMCS

Maintained Contact, Surface Mount

1/2

*Two contacts in the BT contact block are actuated independently

Furnished with
one
contact block
XHMCD

Description of operators only

Weight
Each
Pounds

Maintained Contact Unit

1

Two Push Buttons, Panel Mount
1

1 —4

1

3

1 —4

1

1 —4

1 —4

1

1 —4

XHMCSD

1

3
1 —4

1 —4

Maintained Contact Unit

1

Two Push Buttons, Surface Mount

1

1 —4

XHMCMD

Maintained Contact Unit

1

Two Push Buttons, Panel Mount
With one mushroom and one
standard button
XHMCMSD

Maintained Contact Unit

1

Two Push Buttons, Surface Mount
With one mushroom and one
standard button

Group CD Only
The XHMCD and XHMCSD maintained contact units require only one
contact block. These units consist of two operators and require two
mounting positions.
Legend Plates, see page 9A–19.

278
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 279
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Selector Switches
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Selector Switch Operators

For use with
series BT
contact blocks

Description of operators only

9A–9

All operators are die cast aluminum alloy. The barrels are all 3/4”
NPSM thread. Maximum installation thickness: 1 15/16” panel
mount, 3/4” surface mount. Selector switch operators can be used
as 2 position or 3 position by removal of knob and rotating knob
180°. The actuator cam which operates the plungers on the contact
blocks can be readily changed for various contact sequences. FOR 3
POSITION, ORDERS MUST STATE CAM NUMBER. Contact blocks
are not included with XHSS operators. Select contact block and
sequence operating cam from contact block page 9A–20.
All operators have black molded nylon knobs. The exposed metal
parts are black anodized aluminum. Metal caps are also available in
blue, gold, clear, red or green with black knobs. Specify colors
required.
Weight
Each
Pounds

XHSS

Panel Mount

1/2

XHSSS

Surface Mount

1/2

XHSC

Spring Return to Center

1/2

from Right and Left
Panel Mount
XHSSC

Spring Return to Center

1/2

XHSR

XHSSR

3 POSITION ONLY

from Right and Left
Surface Mount
Spring Return to Center

1/2

from Right, Maintain Left
Panel Mount
Spring Return to Center

1/2

from Right, Maintain Left
Surface Mount

XHSL

Spring Return to Center

1/2

from Left, Maintain Right
Panel Mount
XHSSL

Spring Return to Center

1/2

from Left, Maintain Right
Surface Mount
XHSSPL

W/padlock device Panel Mount

3/4

XHSSSPL

W/padlock device Surface Mount

3/4

XSSL-4P

Panel Mount, Four Position

3/4

Selector Switch
XSSL-5P

Switch Included

Panel Mount, Five Position

3/4

Selector Switch
XSSS-4P

Surface Mount, Four Position

3/4

Selector Switch
XSSS-5P

Surface Mount, Five Position

3/4

Selector Switch

For extremely wet-dirty location applications, use Protective
Boots Page 9A–19. EXCLUDES PADLOCK DEVICES.

Legend Plates, see page 9A–19.
279

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 280
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Selector Switches
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Selector Switch Operators

9A–10

Cost effective modular operator body. The barrels are all 3/4” NPSM
thread aluminum. Maximum installation thickness: 1 15/16” panel
mount, 3/4” surface mount. Selector switch operators can be used as
2 position or 3 position by removal and rotation of the cam actuator.
The cam which operates the plungers on the contact blocks can be
changed for various contact sequences. FOR 3 POSITION, ORDERS
MUST STATE CAM NUMBER. Contact blocks are not included with
XVHSS operators. Select contact block and sequence operating cam
from contact block page 9A–20.
All operators have black molded nylon knobs. The exposed metal parts
are black anodized aluminum. Metal caps are also available in blue,
gold, clear, red or green with black knobs. Specify colors required.

For use with
series BT
contact blocks

Description of operators only

Weight
Each
Pounds

XVHSS

Panel Mount

1/2

XVHSSS

Surface Mount

1/2

XVHSSPL

W/padlock device Panel Mount

3/4

XVHSSSPL

W/padlock device Surface Mount

3/4

Legend Plates, see page 9A–19.

For extremely wet-dirty location applications, use Protective
Boots Page 9A–19. EXCLUDES PADLOCK DEVICES.

The selector switch for Series BT blocks have a sequence actuating
cam as an integral part of the operator. THE CAM NUMBER MUST
BE INCLUDED IN THE OPERATOR DESCRIPTION WHEN
ORDERING. THE CAM NUMBERS ARE SHOWN IN THE CIRCUIT
ARRANGEMENT CHARTS, SEE PAGE 9A–20.
280
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 281
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Selector Switches
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Keylock Selector Switch Operators

Key removable one position only

For use with
series BT
contact blocks

Description of operators only

Weight
Each
Pounds

XHKSS

Key Lock Operation

1/2

9A–11

All operators are die cast aluminum alloy. The barrels are all 3/4”
NPSM thread. Maximum installation thickness: 1 15/16” panel
mount, 3/4” surface mount. Selector switch operators can be used
as 2 position or 3 position by removal of knob and rotating knob
180°. The actuator cam which operates the plungers on the contact
blocks can be readily changed for various contact sequences. FOR 3
POSITION, ORDERS MUST STATE CAM NUMBER. Contact blocks
are not included with operators. Select contact block and sequence
operating cam from contact block page 9A–20.
The exposed metal parts are black anodized aluminum.

specify right, center or left
Panel Mount
XHKSSS

Key Lock Operation

1/2

Surface Mount
XHKSC

Spring Return to Center

1/2

from Right and Left
Panel Mount
XHKSSC

Spring Return to Center

1/2

from Right and Left

XHKSSR

3 POSITION ONLY

Surface Mount
XHKSR

Spring Return to Center

1/2

from Right, Maintain Left
Panel Mount
Spring Return to Center

1/2

from Right, Maintain Left
Surface Mount

XHKSL

Spring Return to Center

1/2

from Left, Maintain Right
Panel Mount
XHKSSL

Spring Return to Center

1/2

from Left, Maintain Right
Surface Mount

Legend Plates, see page 9A–19.

The selector switch for Series BT blocks have a sequence actuating
cam as an integral part of the operator. THE CAM NUMBER MUST
BE INCLUDED IN THE OPERATOR DESCRIPTION WHEN
ORDERING. THE CAM NUMBERS ARE SHOWN IN THE CIRCUIT
ARRANGEMENT CHARTS, SEE PAGE 9A–20.
281
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 282
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Selector Switches
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Keylock Selector Switch Operators

9A–12

Cost effective modular operator body. The barrels are all 3/4” NPSM
thread aluminum. Maximum installation thickness: 1 15/16” panel
mount, 3/4” surface mount. Selector switch operators can be used as
2 position or 3 position by removal and rotation of the cam actuator.
The cam which operates the plungers on the contact blocks can be
changed for various contact sequences. FOR 3 POSITION, ORDERS
MUST STATE CAM NUMBER. Contact blocks are not included with
operators. Select contact block and sequence operating cam from
contact block page 9A–20.
The exposed metal parts are black anodized aluminum.

XVHKSS

XVHKSSS

Key removable one position only

For use with
series BT
contact blocks

Description of operators only

Weight
Each
Pounds

XVHKSS

Key Lock Operation,

1/2

Panel Mount

specify right, center or left
XVHKSSS

Key Lock Operation,

1/2

Surface Mount

Legend Plates, see page 9A–19.

The selector switch for Series BT blocks have a sequence actuating
cam as an integral part of the operator. THE CAM NUMBER MUST
BE INCLUDED IN THE OPERATOR DESCRIPTION WHEN
ORDERING. THE CAM NUMBERS ARE SHOWN IN THE CIRCUIT
ARRANGEMENT CHARTS, SEE PAGE 9A–20.
282
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 283
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Potentiometer and Switch Operators
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Potentiometer and Switch Operators
Operators are die cast aluminum alloy. The barrels are all 3/4” NPSM
thread. 1/4” diameter shafts. Maximum installation thickness:
1 15/16” panel mount, 3/4” surface mount. XPO-XPOS have knob
and dial marked 1 to 100. Two dial sizes are available. XPOC-XPOCS
have 15 turn counting dial. Operators include 3 pc. coupling and
device mounting bracket.
Weight
Each
Pounds

Description

XPO

Plain Dial, Panel Mount

1/2

XPOS

Plain Dial, Surface Mount

1/2
1/2

XPOL

Plain Dial, Large Size, Panel Mount

XPOSL

Plain Dial, Large Size, Surface Mount

1/2

XPOC

Counting Dial, Panel Mount

3/4

XPOCS

Counting Dial, Surface Mount

3/4

9A–13

Catalog No.

POTENTIOMETER NOT FURNISHED — Consult Factory.

CLASS I, GROUPS C & D;
CLASS II, GROUPS E, F & G; NEMA 7, 9
Manual and Motor Operated Rotating Shafts
XCS manual operated shafts suitable for potentiometers, rheostats
and other devices requiring external adjustment. Includes 3 piece
coupling to compensate for misalignment.
XCF motor operated shafts suitable for tachometers and rotating
equipment with speeds to 5000 rpm. Shaft is ball bearing mounted.
Includes flexible coupling to compensate for misalignment.
Dimension in Inches
Cat. No.

Shaft Dia.

A

B

C

D

E (NPSM)

XCS-1

1/8

6

2 1/2

1

2 1/2

3/4-14

XCS-2

1/4

6

2 1/2

1

2 1/2

3/4-14

XCS-3

5/16

6

2 1/2

1

2 1/2

3/4-14

XCS-4

3/8

6

2 1/2

1

2 1/2

3/4-14

XCS-5

1/2

6

2 1/2

1

2 1/2

3/4-14

XCF-1

1/8

6

2 3/16

1 5/8

2 3/16

1/2-14

XCF-2

1/4

6

2 1/8

1 3/4

2 1/8

3/4-14

XCF-3

5/16

6

2

2

2

1-11 1/2

XCF-4

3/8

6

2

2

2

1-11 1/2

XCF-5

1/2

6

2

2

2

1 1/4-11 1/2

NOTE: NEMA 3, 4 Features Available for XCF Only
283
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 284
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Potentiometer and Switch Operators

CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Potentiometer Operators
Cost effective modular operator body. The barrels are all 3/4” NPSM
thread aluminum. 1/4” diameter shafts. Maximum installation
thickness: 1 15/16” panel mount, 3/4” surface mount. XVPO-XVPOS
have knob and dial marked 1 to 100. Two dial sizes are available.
XVPOC-XVPOCS have 15 turn counting dial. Operators include 3 pc.
coupling and device mounting bracket.

9A–14

Catalog No.

Description

Weight
Each
Pounds

XVPO

Plain Dial, Panel Mount

1/2

XVPOS

Plain Dial, Surface Mount

1/2

XVPOL

Plain Dial, Large Size, Panel Mount

1/2

XVPOSL

Plain Dial, Large Size, Surface Mount

1/2

XVPOC

Counting Dial, Panel Mount

3/4

XVPOCS

Counting Dial, Surface Mount

3/4

POTENTIOMETER NOT FURNISHED — Consult Factory.

284
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 285
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Pilot Lights
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9

Explosionproof pilot lights are suitable for panel or surface mount applications. All pilot
lights are of sealed construction and can be relamped from the front by removal of
lens cap.
All pilot lights are made with 3/4” NPSM threads. All pilot lights have 8” flexible leads,
other lengths on special order, or screw terminal (suffix T).
All lens caps are black anodized aluminum finish.
Maximum installation thickness: 1 15/16” on Long Series, 5/8” on Short Series.
This standard series of pilot lights is equipped with candelabra base receptacles and 6
watt 120 volt 6S6 clear 1500 hr. avg. lamps. Also available with 6, 12, 24, 30, 50, 75
and 135 volt lamps. Specify voltage desired.
Weight
Each
Pounds

Catalog No.
Panel Mount

Catalog No.
Surface Mount

Description

XLA-GH

XLSA-GH

Amber Lens

1/2

XLB-GH

XLSB-GH

Blue Lens

1/2

XLC-GH

XLSC-GH

Clear Lens

1/2

XLG-GH

XLSG-GH

Green Lens

1/2

XLR-GH

XLSR-GH

Red Lens

1/2

XLW-GH

XLSW-GH

White Lens

1/2

*Add suffix T to P/N for screw terminal

This special series of pilot lights is equipped with slide base receptacles and 120 volt
5000 hr. avg. lamps with slide base. Also available with 6, 12, 24, 48 and 60 volt
lamps. Specify voltage desired.

Catalog No.
Panel Mount

Catalog No.
Surface Mount

Description

Weight
Each
Pounds

XLAS-GH

XLSAS-GH

Amber Lens

1/2

XLBS-GH

XLSBS-GH

Blue Lens

1/2

XLCS-GH

XLSCS-GH

Clear Lens

1/2

XLGS-GH

XLSGS-GH

Green Lens

1/2

XLRS-GH

XLSRS-GH

Red Lens

1/2

XLWS-GH

XLSWS-GH

White Lens

1/2

*Add suffix T to P/N for screw terminal

Replacement Guarded Lens Cap Assembly
Catalog No.

Description

Weight
Each
Pounds

XLA-GCH

Amber Lens

1/8

XLB-GCH

Blue Lens

1/8

XLC-GCH

Clear Lens

1/8

XLG-GCH

Green Lens

1/8

XLR-GCH

Red Lens

1/8

XLW-GCH

White Lens

1/8

285
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

9A–15

Guarded Pilot Lights for Group B Application

15599 Sec.9 12/9/01 11:19 AM Page 286
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Pilot Lights
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9
Guarded Pilot LED Lights
for Group B Application
LED Advantages:
• 10 Year/100,000 hour service life under normal ambient conditions.
• 1x to 4x more energy efficient.
• Improved resistance to shock and vibration.
• LEDs operate significantly cooler than traditional lamps.

9A–16

• Ultra bright cluster LED’s.
Explosionproof pilot LED lights are suitable for panel or surface mount
applications. All candelabra base LED lights and can be relamped from
the front by removal of the lens cap.
All pilot LED lights are made with 3/4” NPSM threads. All pilot LED
lights have 8” flexible leads, other lengths on special order, or
screw terminal.
Add suffix T to P/N for screw terminal.
All lens caps are black anodized aluminum finish with clear glass lens.
Maximum installation thickness: 1-15/16” on Panel Mount (Long
Series), 5/8” on Surface Mount (Short Series).
Consult Adalet for the availability of other voltages.
Catalog No.
Panel Mount
(Long Series)

Catalog No.
Surface Mount
(Short Series)

Description

Weight
Each
Pounds

XLRL-GH
XLAL-GH
XLGL-GH
XCWL-GH
XLBL-GH

XLSRL-GH
XLSAL-GH
XLSGL-GH
XLSWL-GH
XLSBL-GH

Red
Amber
Green
White
Blue

1/2
1/2
1/2
1/2
1/2

*Add suffix T to P/N for screw terminal.

286
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 287
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Special Operators and Accessories
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 3, 4, 7, 9

Reset Button Operators
Description of operations only

Weight
Each
Pounds

XRB

Reset Button - Short

1/2

XRBL

Reset Button - Long

1/2

Used for resetting contactors, relays, etc. in explosionproof and weather-proof
enclosures. Made with 3/4” NPSM threaded stem. Standard operating shaft
length 6” can be cut to length. Special lengths are also available. Use XRBL for
wall thickness greater than 3/4”.

9A–17

XRB / XRBL

Catalog No.

Close-Up Plugs
For Unused Operator Openings
Catalog No.

Description of operations only

Net
Weight

XPP

3/4” NPSM

3/4 oz.

XPP-N4

3/4” NPSM Type 4

3/4 oz.

287
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 288
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-Tight Pilot Lights
CLASS I, GROUPS C & D
Non-Guarded Lens Caps

Catalog No.

Description

All lens caps are black anodized aluminum finish. For color
coding, Adalet will furnish at no additional charge the
following color combinations:

XLA-C

Amber Lens

Black

1/2

XLB-C

Blue Lens

Black

1/2

XLC-C

Clear Lens

Black

1/2

• Black Cap

XLG-C

Green Lens

Black

1/2

• Clear Cap

XLR-C

Red Lens

Black

1/2

XLW-C

White Lens

Black

1/2

1/2

• Amber Cap
• Green Cap

Cap Color

Weight
Each lbs.

9A–18

XLAC-C

Amber Lens

Clear

• Blue Cap

XLBC-C

Blue Lens

Clear

1/2

• Red Cap

XLCC-C

Clear Lens

Clear

1/2

XLGC-C

Green Lens

Clear

1/2

XLRC-C

Red Lens

Clear

1/2

XLWC-C

White Lens

Clear

1/2

XLAA-C

Amber Lens

Amber

1/2

XLBA-C

Blue Lens

Amber

1/2
1/2

XLCA-C

Clear Lens

Amber

XLGA-C

Green Lens

Amber

1/2

XLRA-C

Red Lens

Amber

1/2

XLWA-C

White Lens

Amber

1/2

XLAG-C

Amber Lens

Green

XLBG-C

Blue Lens

Green

1/2

XLCG-C

Clear Lens

Green

1/2

XLGG-C

Green Lens

Green

1/2

XLRG-C

Red Lens

Green

1/2

XLWG-C

White Lens

Green

1/2

XLAB-C

Amber Lens

Blue

1/2

XLBB-C

Blue Lens

Blue

1/2

XLCB-C

Clear Lens

Blue

1/2

XLGB-C

Green Lens

Blue

1/2

XLRB-C

Red Lens

Blue

1/2

XLWB-C

White Lens

Blue

1/2

XLAR-C

Amber Lens

Red

1/2

XLBR-C

Blue Lens

Red

1/2

XLCR-C

Clear Lens

Red

1/2

XLGR-C

Green Lens

Red

1/2

XLRR-C

Red Lens

Red

1/2

XLWR-C

White Lens

Red

1/2

288
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 289
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Operator Boots and Hardware

Operator Protective Boots
Molded silicone rubber, protective boots for use with explosion
proof operators in extremely wet-dirty locations. Makes
operators suitable for NEMA 3, 4, 4X, 5, 7, 9, 12, 13
application. Boot and metal collar are an integral assembly
available as a factory adder or a field replacement.
Simple installation requires removal of existing cap and
threading on the replacement.

XBPC

XNP

Catalog No.

XHDPL
XMB

Description

Weight
Each

XBB

Black Push Button Cap

1 oz.

XBG

Green Push Button Cap

1 oz.

XBR

Red Push Button Cap

1 oz.

XBSB

Black Selector Switch Cap

1 oz.

XBSG

Green Selector Switch Cap

1 oz.

XBSR

Red Selector Switch Cap

1 oz.

XBPC

Clear Pilot Light Push Button Cap

1 oz.

9A–19

XBB

XBSB

To order as complete operator add part number as suffix.
XMC

XHPL

XMT

Catalog No.

Description

Weight
Each

XNPWB

Black Blank Legend Plate

1/16

XNPWG

Green Blank Legend Plate

1/16

XNPWR

Red Blank Legend Plate

1/16

Legend plate has foam gasket backing for use with protective
boots for sealing. Engraving 1 line only see Price List.

XHSPL

Push Button and Selector Switch
Components
Operator locking caps and actuator devices can be adapted to
existing explosion proof operators. Simple installation requires
removal of top cap and threading on the replacement unit.

Legend Plates Standard Marking
For Push Button

For Selector switches

(BLANK)

SLOW

RESET

RUN-JOG

OPEN-OFF-CLOSE

START

OPEN

IN

HAND-AUTO

FAST-OFF-SLOW

INCH

CLOSE

OUT

FWD-REV

RUN-AUTO-JOG

STOP

UP

LEFT

FAST-SLOW

RUN

JOG

RIGHT

OPEN-CLOSE FWD-OFF-REV

HAND-OFF-AUTO

FORWARD ON

LOW

UP-DOWN

1-OFF-2

REVERSE

HIGH

OFF-ON

UP-OFF-DOWN

FAST

OFF
BACK

DOWN

Catalog No.

Padlock Device for Dual Push Button

1/4

XHPL

Padlock Device to activate Push Button

1/4

XHSPL

Padlock Device for Selector Switch

1/4

XMB

Red Mushroom Head 2 1/4” Button

1/4

XMC

Maintained Contact Lever for

1/4

Push Buttons

EMERGENCY STOP

XNP

Description
Specify legend

Weight
Each

XHDPL

XMT

Catalog No.

Description

Wobble Stick 2 1/2” Long for NC

1/4

Push Button

Weight
Each

XHPLG

Padlockable Push Button Cover

1/4

(Not Shown)

1/16

Legend plates are anodized aluminum with engraved letters on
black background. Stop has red and start has green
background. Special engraved legend plates can be supplied.

Mushroom button and wobble stick recommended only for
operators with normally closed contact blocks.

289
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 290
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Push Button and Selector Switch Components

600 Volts AC Maximum Contact Blocks
for Push Buttons and Selector Switches
Series BT
Catalog

Contact Block

Push Button

BT1A

One Open and

1 N.O.

One Closed

1 N.C.

BT1B

Selector Switch

Weight Ea.
1/10

One Closed and One Open

See
Chart

9A–20

(this is BT1A block

1 N.C.

rotated 180 degrees

1 N.O.

1/10

1 N.O.

1/10

when assembled to
operator)
BT2

Two open

1 N.O.
1 N.C.
BT3

Two closed

1 N.C.

BT4

One open

1 N.O.

BT5

One closed

1 N.C.

BT44

Two open

1 N.C.

Two closed

1 N.O.

1/10
Specify
Cam
and
Contact
Block

1/10
1/10
1/10

1 N.O.

1 N.C.

Contact Sequence Chart
2-Position
Selector
Switches
Cam 1
Contact
Sequence

O = Contact Open
X = Contact Closed
Circuit of Contact Block

Contact
Block
Number

3-Position Selector Switches
Cam 2
Cam 3
Cam 4
Contact
Contact
Contact
Sequence Sequence Sequence

Cam 5
Cam 6
Contact
Contact
Sequence Sequence

Normally Closed (NC)
Normally Open (NO)

BT1A

Circuit A
Circuit B

XO
OX

OX O
OO X

OXX
OOX

XOO
OXO

OXX
X XO

XOO
OXO

Normally Closed (NC)
Normally Open (NO)

BT1B*

Circuit B
Circuit A

XO
OX

XX O
XO X

X XO
X OO

XOX
OX X

OOX
X OO

OOX
OOX

Normally Open(NO)
Normally Open (NO)

BT2

Circuit A
Circuit B

OX
OX

XO X
OO X

X OO
OOX

OX X
OXO

X OO
X XO

OOX
OXO

Normally Closed (NC)
Normally Closed (NC)

BT3

Circuit A
Circuit B

XO
XO

OX O
XX O

OXX
X XO

XOO
XOX

OXX
OOX

XOO
OOX

* This contact block is same as BT1A one N.C. and one N.O. except rotated 180° when
assembled to operator.

Maximum Ampere Rating Control Circuit Contacts Type BT
AC
Volts
Make & Emergency Interrupting Capacity
Normal Load Break
Continuous Current

110
60.
6.
10.

220
30.
3.
10.

440
15.
1.5
10.

550
12.
1.2
10.

120
1.1
1.1
10.

DC
240
0.5
0.5
10.

600
0.2
0.2
10.

290
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:19 AM Page 291
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Miniature Operators

CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 4, 7 & 9
Features
• Reduce size of control enclosure requirements in hazardous environments.
• Mount on 1” centers vs. standard operators requiring 2 1/2” centers.
• No special enclosures required; can be installed in most Adalet standard
explosionproof enclosures.

Push Button / Selector Switch Description

9A–21

• 3/8”-16 UNC thread size body.
• Black anodized body, cap, button or knob
• Two lengths available: Long Series
Accommodates up to 1 9/16”
enclosure wall thickness
Short Series
Accommodates up to 13/16”
enclosure wall thickness
• Stainless steel actuator shaft.
• Optional red or green button (Push button Operator only)

Push Buttons
XMOB

Catalog No.
Panel Mount

Catalog No.
Surface Mount

Contact
Configurations

Weight
Each

XMOB-1
XMOB-2

XMOBS-1

SPDT maintained

1 oz.

XMOBS-2

SPDT momentary

1 oz.

XMOB-3*

XMOBS-3*

DPDT maintained

1 oz.

XMOB-4

XMOBS-4

DPDT momentary

1 oz.

* Not UL or CSA Approved

• Solid silver contacts rated 5 amps at 125 VAC, 3 amps at 250 VAC.
• Insulation resistance 1000 megohm minimum.
• Furnished with contact block having 8” wire leads, other lengths available.

Selector Switches

XMOS

Catalog No.
Panel Mount

Catalog No.
Surface Mount

Contact
Configurations

Weight
Each

XMOS-1

XMOSS-1

Single Pole, 12 position

1 oz.

XMOS-2

XMOSS-2

Double Pole, 5 position

1 oz.

XMOS-3

XMOSS-3

Three Pole, 3 position

1 oz.

• Selector switches provided with internal adjustable stop.
• Silver contacts rated 150 m.a. at 30 VAC, NEC CL 2 circuit.
• Insulation resistance 10,000 megohms minimum.
• Furnished with contact block having solder type wire connectors.

291
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.9 12/9/01 11:20 AM Page 292
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof and Dust-tight Miniature Operators
CLASS I, GROUPS B, C & D;
CLASS II, GROUPS E, F & G; NEMA 4, 7, 9
For Explosionproof Control Enclosures
Indicator Led Light Description

9A–22

• Up to 100,000 hours lamp life.
• Standard 12 VDC furnished. Optional 24 VDC, or 12, 24, 120 VAC available.
• Black anodized body and lens cap.
• 3/8” - 16 UNC thread size body.
• One length-accommodates up to 1 5/16” enclosure wall thickness.
• Furnished with 8” flexible wire leads, other lengths available.

Catalog No.

Description

Weight
Each
1 oz.

XMOLR

Red Indicator Light

XMOLA

Amber Indicator Light

1 oz.

XMOLG

Green Indicator Light

1 oz.

Close-Up Plugs for Unused Operator Openings
Catalog No.

Weight

XMPP

1/2 oz.

Legend Plates Standard Marking

Catalog No.

Description

Weight
Each

XMNP

Specify legend

1/2 oz.

For Push Button

Compliances:
NEC Class I, Groups B, C & D
Class II, Groups E, F & G
UL Standard 698
CSA Standard C22.2 No. 30

For Selector switches

(BLANK)

SLOW

RESET

RUN-JOG

START

OPEN

IN

HAND-AUTO

INCH

CLOSE

OUT

FWD-REV

STOP

UP

LEFT

FAST-SLOW

RUN

JOG

RIGHT

OPEN-CLOSE

FORWARD

ON

LOW

UP-DOWN

REVERSE

OFF

HIGH

OFF-ON

FAST

BACK

• Legend plates are anodized aluminum with engraved letters on black
background.
• Maximum 10 characters, 5/64” high offered as standard.
NOTE: Special engraved legend plates can be supplied.

292
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 237

7B–1

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

PriStar Specifications
Features and Benefits
• Lightweight, corrosion-resistant, copper-free aluminum alloy (0.3% max. copper content).
• All operating shafts are stainless steel for corrosion resistance.
• Durable cast on lugs cannot get lost.
• Ground screw is highly visible and accessible.
• Uniform wall thickness (not ribbed) for versatility of conduit openings assuring 5 full threads
engagement and maximum available area for conduit drilling and tapping.
• Operators may be mounted through back wall for panel mounting.
• Box depth provides for the stacking of 2 contact blocks.
• Anodized aluminum operators install easily in the field.

Certifications/Compliances
E53505
LISTED

Certified LR36172

*

*CSA certified products require
guarded pilot devices.
Class I, Groups C&D
Class II, Groups E, F, G
Class III
For NEMA 4 or special machining
options, see XIFC Series in Section 5.

Table A2 Control Station Boxes
Number of
Operators

Surface
Mount

Panel
Mount

Std. Cond.
Size (inches)

1
2
3
4
5
6
7
8
12
15
18

X1
X2
X3
X4
X5
X6
X7
X8
X12
X15
X18

X1P
X2P
X3P
X4P
X5P
X6P
X7P
X8P
X12P
X15P
X18P

3/4
3/4
3/4

1
1 1/4
1 1/4
1 1/4
1 1/4
1 1/2
1 1/2
1 1/2

Applicable Standard
Underwriters Laboratories: UL 698,
CSA C22.2 No. 30.

Surface Mount: Operators mounted in cover
Panel Mount: Operators mounted in back
Note: All operator holes are 3/4"-14 NPSM

Table B2 Pilot Lights & Lighted Pushbutton

Lens Color
Amber
Blue
Clear
Green
Red
White

Suffix Nos. for
Std. Pilot Lt.
Candelabra Base
1000 Hr. Lamp
60
61
62
63
64
65

Suffix Nos. for
Guarded Pilot Lt.
Candelabra Base
337
338
339
340
341
342

Suffix Nos. for
Pilot Lt.
Slide Base
5000 Hr. Lamp
66
67
68
69
70
71

Suffix Nos. for
Guarded Pilot Lt.
Slide Base

Suffix Nos. for
Lighted Pushbutton

343
344
345
346
347
348

30
35
40
45
50
55

237
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 238
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

7B–2

PriStar Box & Suffix Numbers

Table C2 Selector & Key Switch Suffix Numbers
Selector Switch Suffix Numbers
Contact
Block/Cam
Included

Contact
Sequence

Standard
Sel. Switch

Sel. Switch
w/ Padlock

Spring Ret.
Center
from R & L

Key Switch Suffix Numbers

Spring Ret.
Center
from R

Spring Ret.
Center
from L

Standard
Key Switch

Spring Ret.
Center
from R & L

Spring Ret.
Center
from R

Spring Ret.
Center
from L

BT1A/1

NO
NC

XO
OX

6

283

82

BT1B/1

NC
NO

OX
XO

7

284

83

BT2/1

NO
NO

OX
OX

8

285

84

BT3/1

NC
NC

XO
XO

9

286

85

BT2/3

NO
NO

XOO
OOX

10

293

111

135

159

86

229

249

269

BT1B/2

NC
NO

XOX
XXO

11

288

112

136

160

87

224

244

264

BT2/2

NO
NO

XOX
OOX

12

289

113

137

161

88

225

245

265

BT3/2

NC
NC

OXO
XXO

13

290

114

138

162

89

226

246

266

BT3/3

NC
NC

OXX
XXO

14

294

115

139

163

90

230

250

270

BT1A/2

NO
NC

OXO
OOX

15

287

116

140

164

91

223

243

263

BT1A/3

NO
NC

OXX
OOX

16

291

117

141

165

92

227

247

267

BT1B/3

NC
NO

XOO
XXO

17

292

118

142

166

93

228

248

268

Contact blocks and cam included with selector switch.

O = Contact Open
X = Contact Closed

Table D2 Pushbutton Suffix Numbers

BT1A
BT2
BT3
BT4
BT5

Contact
Configuration

Momentary
Pushbutton

Momentary
Pushbutton
w/ Padlock

1NO/1NC
2NO
2NC
1NO
1NC

1
2
3
4
5

307
308
309
310
311

Mushroom Head
Momentary
Pushbutton
106
107
108
109
110

1

Dual Pushbutton
Momentary
72
73
74

2

Dual Pushbutton
w/ Lockout
322
323
324

2

Dual Pushbutton
Maint.
77
78
79

2

Dual Pushbutton
Maint. w/ Lock

2

327
329
329

Pushbuttons furnished with Black collars and knobs as standard.
Optional knobs: Green, Red. Optional Collars: Blue, Green, Gold,
Red or Aluminum (unpainted).
1 Standard knob is Red. Black or Green available.
2 Standard with one Green knob labeled “Start” and one Red
knob labeled “Stop.” Unlabeled Black knobs available.

Other pilot devices available – Consult Factory.

238
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 239

7B–3

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

PriStar Dimensions

4 1/2"
4 5/16"

BT

3 1/4"

1"
A

B

1 1/2"

Dimensions

Enclosure
X1
X2
X3
X4
X5
X6
X7
X8
X12
X15
X18

Nom. Inside
Dim.
030303
030603
030703
030903
031103
031303
031503
031803
032403
033003
033603

Dim. in Inches
B
A
4 1/2
7
8
10
12
14
16
19
25
31
37

5 1/2
8
9
11
13
15
17
20
26
32
38

Est. Weight
(lbs.)
5
7
8
10
11
12
13
16
21
28
33

*Std. Conduit
Size (inches)
3/4
3/4
3/4

1
1 1/4
1 1/4
1 1/4
1 1/4
1 1/2
1 1/2
1 1/2

Control Stations have conduit openings centered on top and bottom.
*Consult factory for other conduit sizes.

239
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.7 12/9/01 11:14 AM Page 240
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

7B–4

PriStar Ordering Information

To Order
To order control stations, determine the number of
operators required. Select the control station box by
operator quantity and mounting type from Table A2.
Order operators by suffix numbers from Tables B2, C2
and D2. Add suffix numbers to box number and separate

by dashes. All operator holes must be filled by an
operator. Use suffix “0” for plugs to fill unused space.
Installation of operators will be made from top to bottom
in sequence as listed. Select optional legend plates from
Table F2 below.

Table F2 Legend Plate Standard Markings
Pushbuttons/Pilot Lights
Blank
Start
Inch
Stop
Run
Forward
Reverse
Fast

Slow
Open
Close
Up
Jog
On
Off
Back

Selector Switches
Reset
In
Out
Left
Right
Low
High
Down
E-Stop

Run-Jog
Hand-Auto
Forward-Reverse
Fast-Slow
Open-Close
Up-Down
Off-On

Open-Off-Close
Fast-Off-Slow
Run-Auto-Jog
Hand-Off-Auto
Forward-Off-Reverse
1-Off-2
Up-Off-Down

Legend plates are anodized
aluminum with engraved letters on
black background.
Stop has red and start has green
background.
Special engraved legend plates can
be supplied.

Contact Ratings PriStar
AC
Volts
Make & Interrupting Capacity A
Normal Load Break
A
Continuous Current
A

110
60
6.0
10

DC

220
30
3.0
10

440
15
1.5
10

550
12
1.2
10

120
1.1
1.1
10

240
0.5
0.5
10

600
0.2
0.2
10

240
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:10 AM Page 213
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Cover

Solid Threaded Cover

Threaded Dome Cover

Threaded Glass Cover

Applications:
• Adalet Junction Boxes and Instrument Housings are designed for installation in
electrical conduit systems for hazardous environments.
• Wiring: Pull boxes, splices, taps and terminal strips.
• Housing for apparatus, instruments and other equipment.

Features
• Rugged sand-cast aluminum copper-free alloy — 0.3% max. copper content.
• Tumblasted for quality appearance.
• Cast-on mounting lugs, ease of field installation.
• Grounding screw standard.

Options
• NEMA 3, 4 available; Features installation of an O-ring gasket on cover.
• Conduit openings available, drilled and tapped to customer requirements.
• Cast-on mounting buttons, bosses and pads available.

6A–1

Notes:
Where reference is made to Class I and Class II hazardous locations, the
equipment is suitable for use in both Division 1 and Division 2 hazardous
locations.

213
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 214
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Cover
CLASS I GROUPS C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9

XJD

XJX

XJHC

XJDA

XJS
(Can be tapped on
side pads only)

XJM

XJMA

XJHB

XJK

XJL

XJT

XJMC

XJHA

XJKA

XJN

Certifications

XJWH

Compliance
• NEC Class I, Groups C & D,
Class II, Groups E, F & G
• UL Standard 1203
• Investigated to CSA Standard C22.2
No. 30 by UL
Drilled and tapped to specification,
attach layout sheet.

XJWT

6A–2
214
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 215
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Window Cover
METER AND INSTRUMENT HOUSINGS
EXPLOSIONPROOF AND DUST-TIGHT
CLASS I, GROUPS C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9

XJDGC
XJDFGC*

XJMCGC*

XJTGC
XJTFGC*

XJMGC*

XJMAGC*

XJXGC

XJLGC

* includes internal flange and meter mounting plate.

XJNGC 6 & 12

XJHAGC

XJHBGC

XJHCGC

XJKGC

XJKAGC

Certifications

XJWHGC

XJWTGC

Compliance
• NEC Class I, Groups C & D,
Class II, Groups E, F & G
• UL Standard 1203
• Investigated to CSA Standard C22.2
No. 30 by UL
Drilled and tapped to specification,
attach layout sheet.

Back wall mounting plates optional
on some housings. Consult factory.

**XJOGC Enclosure is UL Classified and
CSA Certified

215
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

6A–3

**XJOGC

15599 Sec.6 12/9/01 11:11 AM Page 216
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Cover
CLASS I GROUPS B, C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9

XJDH

XJXH

XJHCH

XJDAH

XJSH
(Can be tapped on
side pads only)

XJMH

XJMAH

XJHBH

XJKH

XJLH

XJMCH

XJKAH

XJTH

XJHAH

XJNH 6 & 12

Certifications

XJWHH

Compliance
• NEC Class I, Groups B, C & D,
Class II, Groups E, F & G
• UL Standard 1203
• Investigated to CSA Standard C22.2
No. 30 by UL
Drilled and tapped to specification,
attach layout sheet.

XJWTH

6A–4
216
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 217
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Window Cover
METER AND INSTRUMENT HOUSINGS
EXPLOSIONPROOF AND DUST-TIGHT
CLASS I, GROUPS B, C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9

XJDGCH
XJDFGCH*

XJMCGCH*

XJTGCH
XJTFGCH*

XJMGCH*

XJMAGCH*

XJXGCH

XJLGCH

* includes internal flange and meter mounting plate.

XJNGCH 6 & 12

XJHAGCH

XJHBGCH

XJHCGCH

XJKGCH

XJKAGCH

Certifications

XJWTGCH

Back wall mounting plates optional
on some housings. Consult factory.

Compliance
• NEC Class I, Groups B, C & D,
Class II, Groups E, F & G
• UL Standard 1203
• Investigated to CSA Standard C22.2
No. 30 by UL
Drilled and tapped to specification,
attach layout sheet.

6A–5

XJWHGCH

217
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 218
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Cover
CLASS I GROUPS C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9
EExd IIB + H2 IP60, IP66 (optional); Exd IIB + H2 IP60, IP66 (optional)

XJDX

XJXX

XJHCX

XJDAX

XJSX
(Can be tapped on
side pads only)

XJMX

XJMAX

XJHBX

XJKX

Certifications

XJWHX

XJWTX

XJLX

XJMCX

XJKAX

XJTX

XJHAX

XJNX 6 & 12

6A–6

Compliance
• NEC Class I, Groups C & D,
Class II, Groups E, F & G
• UL Standard 1203, 2279
• Investigated to CSA Standard C22.2 No.
30 by UL
• CENELEC EN 50.014 & 50.018 EExd
IIB+H2 IP60, (optional IP66 with o-ring
seal)
• IEC 79 Exd IIB + H2 IP60, (optional IP66
with o-ring seal)
• Demko Certified 99E. 124129U
• UL Classified, Class I, Zone 1, Group IIB
Drilled and tapped to specification,
attach layout sheet.

218
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 219
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Window Cover
METER AND INSTRUMENT HOUSINGS
EXPLOSIONPROOF AND DUST-TIGHT
CLASS I, GROUPS C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9
EExd IIB + H2 IP60, IP66 (optional); Exd IIB + H2 IP60, IP66 (optional)

XJDGCX
XJDFGCX*

XJMCGCX*

XJTGCX
XJTFGCX*

XJMGCX*

XJMAGCX*

XJXGCX

XJLGCX

* includes internal flange and meter mounting plate.

XJNGCX 6 & 12

XJHAGCX

XJHBGCX

XJHCGCX

XJKGCX

XJKAGCX

Certifications

XJWTGCX

Back wall mounting plates optional
on some housings. Consult factory.

6A–7

XJWHGCX

Compliance
• NEC Class I, Groups C & D,
Class II, Groups E, F & G
• UL Standard 1203, 2279
• Investigated to CSA Standard C22.2 No.
30 by UL
• CENELEC EN 50.014 & 50.018 EExd
IIB+H2 IP60, (optional IP66 with o-ring
seal)
• IEC 79 Exd IIB + H2 IP60, (optional IP66
with o-ring seal)
• Demko Certified 99E. 124129U
• UL Classified, Class I, Zone 1
Drilled and tapped to specification,
attach layout sheet.
219

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 220
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Cover
CLASS I GROUPS B, C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9
EExd IIB + H2 IP60, IP66 (optional); Exd IIB + H2 IP60, IP66 (optional)

XJDHX

XJXHX

XJHCHX

XJDAHX

XJSHX
(Can be tapped on
side pads only)

XJMHX

XJMAHX

XJHBHX

XJKHX

Certifications

XJWHHX

XJWTHX

XJLHX

XJMCHX

XJKAHX

XJTHX

XJHAHX

XJNHX 6 & 12

6A–8

Compliance
• NEC Class I, Groups B, C & D,
Class II, Groups E, F & G
• UL Standard 1203, 2279
• Investigated to CSA Standard C22.2 No.
30 by UL
• CENELEC EN 50.014 & 50.018 EExd IIB
+ H2 IP60, (optional IP66 with o-ring
seal)
• IEC 79 Exd IIB + H2 IP60, (optional IP66
with o-ring seal)
• Demko Certified 99E.124129U
• UL Classified, Class I, Zone 1, Group IIB
+ H2
Drilled and tapped to specification,
attach layout sheet.

220
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 221
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Window Cover
METER AND INSTRUMENT HOUSINGS
EXPLOSIONPROOF AND DUST-TIGHT
CLASS I, GROUPS B, C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9
EExd IIB + H2 IP60; IP66 (optional); Exd IIB + H2 IP66 (optional)

XJDGCHX
XJDFGCHX*

XJMCGCHX*

XJTGCHX
XJTFGCHX*

XJMGCHX*

XJMAGCHX*

XJXGCHX

XJLGCHX

* includes internal flange and meter mounting plate.

XJNGCHX 6 & 12

XJHAGCHX

XJHBGCHX

XJHCGCHX

XJKGCHX

XJKAGCHX

Certifications

XJWTGCHX

Back wall mounting plates optional
on some housings. Consult factory.

• UL Standard 1203, 2279
• Investigated to CSA Standard C22.2 No. 30
by UL
• CENELEC EN 50.014 & 50.018 EExd IIB +
H2 IP60, (optional IP66 with o-ring seal)
• IEC 79 Exd IIB + H2 IP60, (optional IP66
w/o-ring seal)
• Demko Certified 99E.124129U
• UL Classified, Class I, Zone 1, Group IIB + H2
Drilled and tapped to specification,
attach layout sheet.

221
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

6A–9

XJWHGCHX

Compliance
• NEC Class I, Groups B, C & D,
Class II, Groups E, F & G

15599 Sec.6 12/9/01 11:11 AM Page 222
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Meter Instrument Housings
METER AND INSTRUMENT HOUSINGS
SQUARE WINDOW THREADED STYLE
CLASS I, GROUPS C & D; CLASS II GROUPS E, F, & G;
NEMA 7 & NEMA 9
Designed for 3 1/2" Rectangular Meters

Non Magnetic Copper-free aluminum casting
designed for specific instruments and meters
Features
Recessed window with no exposed hardware or protrusions on the
cover. Provides clean finished appearance compatible with
rectangular meters. Designed for 3 1/2" rectangular and 4 1/2"
round meters. Furnished with cast inside mounting ears to support
adapter plate for meter mounting. Interior neck opening has
clearance for meter face, diagonal dimension 3 13/16" x 3 1/4".

Mounting
Can be surface mounted or panel mounted in panels up to 1/4"
thick. Panel mounting requires 5 5/8" round opening allowing neck
to protrude through the panel and the cover only appears on the
front surface of the panel. Cover locks in position with set screw.
For additional support, the front surface under the cover of the box
can be drilled and tapped with blind holes on 5 1/2" x 5 1/2" centers
for screw attachment. Requires countersunk screw openings in
panel.

XJSWGC

For specific meter application consult factory.
(Meter not included)

6A–10

Certifications
• UL Classified E81696
• CSA Certified LR27991

Compliance
• NEC Class I, Groups C & D,
Class II, Groups E, F & G
• UL Standard 1203
• CSA Standard C22.2 No. 30
Drilled and tapped to specification,
attach layout sheet.

222
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 223
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Cover
JUNCTION BOXES THREADED DOME COVER STYLE
EXPLOSIONPROOF AND DUST-TIGHT
CLASS I, GROUP C & D; CLASS II GROUPS E, F, & G;
NEMA 3, 4 (optional); NEMA 7, 9

XJLD

XJTD

XJHAD
Without Cover
To show Mounting Plate
(Optional)

XJHCD

XJWT

XJKD

XJW

XJKAD

XJWH

XJHAD

XJSD

XJW Modified
To house transfer switch
Modification
(Not UL or CSA)

ADALET Enclosure Systems • Designing Our Products Around Yours

SM

Compliance
• NEC Class I, Division I, Groups C & D,
Class II, Groups E, F & G
• UL Standard 886
• CSA Standard C22.2 No. 30
Drilled and tapped to specification,
attach layout sheet.
223

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

6A–11

Certifications
• UL Listed E10493
• CSA Certified LR27991

15599 Sec.6 12/9/01 11:11 AM Page 224
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Cover

XJD

XJK

XJMGC

XJKD

(D is to glass retaining ring)

(D is to underside of cover)
Base

Inside Nominal

Overall

Mounting

Cover

Window

Catalog

Dimensions

Dimensions

CL to C L

Opening

Viewing
Dia.

Dia.

Number

W

L

XJD

4 1/8

XJDGC

4 1/8

XJDFGC**
XJDA

D

A

B

4 1/8

3 7/8

5 5/16

4 1/8

4 1/16

5 5/16

4 1/8

4 1/8

4 1/16

5 3/4

5 3/4

Flange

Max.

Opening Conduit

Mount.

Ship.

Bolt

Wt.

Size

Size

Pounds
5 3/4

C

E

F

Dia.

5 5/16

4 7/8

6 3/16

3 3/4

3 3/4

-

-

2

3/8

5 5/16

5 9/16

6 3/16

3 3/4

3 3/4

3

-

2

3/8

5

5 5/16

5 5/16

5 9/16

6 3/16

3 3/4

2 7/8

3

2 3/4

2

3/8

6
12

5 7/8

7 1/16

7 1/16

7 1/4

8 3/8

5 1/4

4 3/16

-

-

2

3/8

XJS

4 DIA.

3 3/8

4 7/8

4 7/8

4 1/2

3 3/4

3 3/4

4

-

-

1

1/4

3

XJSD

4 DIA.

4 7/16

4 7/8

4 7/8

5 1/2

3 3/4

3 3/4

4

-

-

1

1/4

3 1/2

XJL

6

6

4 7/8

7

7

6 1/8

8 3/8

5 1/4

5 3/8

-

-

2

3/8

11

XJLD4

6

6

8 9/16

7

7

9 7/8

8 3/8

5 1/4

5 3/8

-

-

2

3/8

12

XJLD6

6

6

10 1/6

7

7

11 7/16

8 3/8

5 1/4

5 3/8

-

-

2

3/8

12 1/4

XJLD10

6

6

14 9/16

7

7

15 15/16

8 3/8

5 1/4

5 3/8

-

-

2

3/8

14

XJLD13

6

6

17 9/16

7

7

18 15/16

8 3/8

5 1/4

5 3/8

-

-

2

3/8

15

XJLGC

6

6

3 7/8

7

7

6 3/16

8 3/8

5 1/4

5 3/8

4

-

2

3/8

11

XJT

5 13/16

6 9/16

5 7/16

6 13/16

7 9/16

6 5/8

7 3/4

6

5 3/8

-

-

2

7/16

12 3/4

XJTD4

5 13/16

6 9/16

9 1/16

6 13/16

7 9/16

10 3/8

7 3/4

6

5 3/8

-

-

2

7/16

13 1/2

XJTD6

5 13/16

6 9/16

10 9/16

6 13/16

7 9/16

11 15/16

7 3/4

6

5 3/8

-

-

2

7/16

14

XJTD10

5 13/16

6 9/16

15 1/16

6 13/16

7 9/16

16 7/16

7 3/4

6

5 3/8

-

-

2

7/16

15 1/2

XJTD13

5 13/16

6 9/16

18 1/16

6 13/16

7 9/16

19 7/16

7 3/4

6

5 3/8

-

-

2

7/16

16 1/2

XJTGC

5 13/16

6 9/16

4 5/16

6 13/16

7 9/16

6 5/8

7 3/4

6

5 3/8

4

-

2

7/16

12 3/4

XJTFGC**

13

5 13/16

6 9/16

4 5/16

6 13/16

7 9/16

6 5/8

7 3/4

6

5 3/8

4

4 1/8

2

7/16

XJX

4 3/4

4 3/4

4 3/16

5 3/4

5 3/4

5 1/2

6 3/4

4 3/4

4 5/8

-

-

2

1/4

7

XJXGC

4 3/4

4 3/4

3 5/16

5 3/4

5 3/4

5 3/8

6 3/4

4 3/4

4 5/8

3

-

2

1/4

7

XJM

6 3/4

6 3/4

10 3/16

7 3/4

7 3/4

11 11/16

9 1/8

6 1/4

7

-

-

2

3/8

22 1/2

XJMGC**

6 3/4

6 3/4

9 1/8

7 3/4

7 3/4

11 1/2

9 1/8

6 1/4

7

5 1/4

5 3/8

2

3/8

22 1/2

XJMA

6 13/16

6 13/16

7 3/16

7 13/16

7 13/16

8 11/16

9 1/8

6 1/4

7

-

-

2

3/8

17

XJMAGC**

6 13/16

6 13/16

6 1/8

7 13/16

7 13/16

8 1/2

9 1/8

6 1/4

7

5 1/4

5 1/4

2

3/8

17

XJMC

6 3/4

6 3/4

5 3/16

7 13/16

7 13/16

6 11/16

9 1/8

6 1/4

7

-

-

2

3/8

13 1/2

XJMCGC**

6 3/4

6 3/4

4 1/8

7 13/16

7 13/16

6 1/2

9 1/8

6 1/4

7

5 1/4

5 3/8

2

3/8

13 3/4

6A–12

XJHA

7 3/16

9 3/16

5 1/4

8 3/16

10 3/16

6 3/4

9 3/4

8 3/4

7

-

-

2

1/2

16 1/2

XJHAD6

7 3/16

9 3/16

11

8 3/16

10 3/16

12 7/16

9 3/4

8 3/4

7

-

-

2

1/2

19 3/4

XJHAD9

7 3/16

9 3/16

14

8 3/16

10 3/16

15 7/16

9 3/4

8 3/4

7

-

-

2

1/2

21 1/2

XJHAD12

7 3/16

9 3/16

17

8 3/16

10 3/16

18 7/16

9 3/4

8 3/4

7

-

-

2

1/2

23 1/2

XJHAGC

7 3/16

9 3/16

4 3/16

8 3/16

10 3/16

6 9/16

9 3/4

8 3/4

7

5 1/4

-

2

1/2

16 1/2

XJHB

7 1/4

9 1/8

7 1/4

8 3/8

10 1/4

8 13/16

9 3/4

8 7/8

7

-

-

2

1/2

22

XJHBGC

7 1/4

9 1/8

6 3/16

8 3/8

10 1/4

8 9/16

9 3/4

8 7/8

7

5 1/4

-

2

1/2

22

Note: Suffix H, X and HX enclosure types are dimensionally identical. **Includes built-in meter mounting provisions; call factory for details.
224
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 225
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Cover
Base

Inside Nominal

Overall

Mounting

Cover

Window

Flange

Catalog

Dimensions

Dimensions

CL to CL

Opening

Viewing

Opening Conduit Bolt

Dia.

Dia.

Number

W

L

D

A

B

C

E

F

Dia.

Max. Mount.
Size

Size

Ship.
Wt.
Pounds

XJHC

7 3/4

10 5/16

6 3/16

8 7/8

11 7/16

7 3/4

10 1/4

7 3/4

7

-

-

2

1/2

23 1/2

XJHCD6

7 3/4

10 5/16

11 15/16

8 7/8

11 7/16

13 7/16

10 1/4

7 3/4

7

-

-

2

1/2

26 3/4

XJHCD9

7 3/4

10 5/16

14 15/16

8 7/8

11 7/16

16 7/16

10 1/4

7 3/4

7

-

-

2

1/2

28 1/2

XJHCD12

7 3/4

10 5/16

17 15/16

8 7/8

11 7/16

19 7/16

10 1/4

7 3/4

7

-

-

2

1/2

30 1/2

XJHCGC

7 3/4

10 5/16

5 1/8

8 7/8

11 7/16

7 9/16

10 1/4

7 3/4

7

5 1/4

-

2

1/2

23 1/2

XJK

9 1/2

11 1/2

7 1/4

10 3/4

12 3/4

9 1/4

12 1/4

8

9

-

-

3

1/2

39 1/4

XJKD6

9 1/2

11 1/2

13 1/16

10 3/4

12 3/4

14 15/16

12 1/4

8

9

-

-

3

1/2

43 3/4

XJKD12

9 1/2

11 1/2

19 1/16

10 3/4

12 3/4

20 15/16

12 1/4

8

9

-

-

3

1/2

49

XJKD18

9 1/2

11 1/2

25 1/16

10 3/4

12 3/4

26 15/16

12 1/4

8

9

-

-

3

1/2

54 3/4

XJKGC

9 1/2

11 1/2

6 3/16

10 3/4

12 3/4

9 1/16

12 1/4

8

9

6 11/16

-

3

1/2

39 1/4

XJKA

9 1/2

11 1/2

9 1/8

10 3/4

12 3/4

11 3/16

12 3/8

8

9

-

-

3

1/2

45 3/4

XJKAD6

9 1/2

11 1/2

15

10 3/4

12 3/4

16 13/16

12 3/8

8

9

-

-

3

1/2

50 1/4

XJKAD12

9 1/2

11 1/2

21

10 3/4

12 3/4

22 13/16

12 3/8

8

9

-

-

3

1/2

55 1/4

XJKAD18

9 1/2

11 1/2

27

10 3/4

12 3/4

28 13/16

12 3/8

8

9

-

-

3

1/2

61 1/4

XJKAGC

9 1/2

11 1/2

8 1/16

10 3/4

12 3/4

11

12 3/8

8

9

6 11/16

-

3

1/2

45 3/4

14 5/8

9 13/16

15 3/8

9

10 11/16

-

-

4

1/2

60 1/2

14 13/16 15 15/16

15 3/8

9

10 11/16

-

-

4

1/2

87 1/2

9 7/8

15 3/8

9

10 11/16

8

-

2

1/2

60 1/2

XJN6

11 1/2

12 3/4

7 7/16

13 3/8

XJN12

11 1/2

12 3/4

13 9/16

13 9/16

XJNGC6

11 1/2

12 3/4

6 3/16

13 3/8

14 5/8

11 1/2

12 3/4

XJNGC12

12 5/16

13 9/16

14 13/16

16

15 3/8

9

10 11/16

8

-

2

1/2

87 1/2

XJWH

6 5/8 DIA

4 3/8

7 15/16

7 15/16

5 15/16

6 3/8

6 3/8

7

-

-

2

3/8

11 1/2

XJWH6

6 5/8 DIA

10 1/8

7 15/16

7 15/16

11 5/8

6 3/8

6 3/8

7

-

-

2

3/8

14 3/4

XJWH9

6 5/8 DIA

13 1/8

7 15/16

7 15/16

14 5/8

6 3/8

6 3/8

7

-

-

2

3/8

16 1/2

XJWH12

6 5/8 DIA

16 1/8

7 15/16

7 15/16

17 5/8

6 3/8

6 3/8

7

-

-

2

3/8

18 1/2

XJWHGC

6 5/8 DIA

3 5/16

7 15/16

7 15/16

5 3/4

6 3/8

6 3/8

7

5 1/4

-

2

3/8

11 1/2

XJW3

4 7/8 DIA

5 5/16

5 11/16

5 11/16

6 7/8

4 1/2

4 1/2

4 7/8

-

-

1 1/4

1/4

5

XJW5

4 7/8 DIA

7 5/16

5 11/16

5 11/16

8 11/16

4 1/2

4 1/2

4 7/8

-

-

1 1/4

1/4

5 3/4

XJWT

5 3/8 DIA

3 13/16

6 3/8

6 3/8

5 1/8

5 1/8

5 1/8

5 3/8

-

-

2

5/16

8

XJWT4

5 3/8 DIA

7 9/16

6 3/8

6 3/8

8 7/8

5 1/8

5 1/8

5 3/8

-

-

2

5/16

9

XJWT6

5 3/8 DIA

9 1/16

6 3/8

6 3/8

10 3/8

5 1/8

5 1/8

5 3/8

-

-

2

5/16

9 1/2

XJWT10

5 3/8 DIA

13 9/16

6 3/8

6 3/8

14 7/8

5 1/8

5 1/8

5 3/8

-

-

2

5/16

11

XJWT13

5 3/8 DIA

16 9/16

6 3/8

6 3/8

17 7/8

5 1/8

5 1/8

5 3/8

-

-

2

5/16

12

XJWTGC

5 3/8 DIA

2 15/16

6 3/8

6 3/8

5 1/8

5 1/8

5 1/8

5 3/8

4

-

2

5/16

8

XJSWGC**
XJOGC

5 1/4

5 1/4

4 1/16

6 1/8

6 1/8

5 5/8

7 1/8

4 3/4

5

3 3/8 x 3 3/8

3 3/4

3/4

5/16

8

8

8

5 1/4

9

9

7 9/16

8

8

7

5 1/4

-

2

5/16

20 1/4

6A–13

Note: Suffix H, X and HX enclosure types are dimensionally identical. **Includes built-in meter mounting provisions; call factory for details.

225
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 226
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Conduit Drilling and Tapping Guidelines For Threaded Enclosure

When drilling & tapping enclosures for conduit, proper installation requires compliance with the following:
1. Must be tapped with at least 5 full NPT threads (suffix X enclosures require 6 NPT threads) in enclosure back
or sides only; min. 1/2" conduit size.
2. Tapping depth of NPT holes must be plus 1/2 turn min. to plus 1-1/2 turns max. past standard NPT plug gage notch.
3. Inner end of conduit openings shall be smooth and well-rounded.

TABLE I
Trade Size Of

Minimum wall thickness at

Conduit, Inches (NPT)

conduit entrance excluding
suffix X enclosures (XCEX)

1/2 - 3/4

3/8 inch

1-2

7/16 inch

2 1/2 - 5

5/8 inch

TABLE II
Conduit size, inches (NPT)

1/2

3/4

1

1 1/4

1 1/2

2

2 1/2

3

3 1/2

4

Minimum Distance from conduit CL
to inside corner or back of box

1 5/16

1 7/16

1 9/16

1 3/4

1 7/8

2 1/8

2 3/8

2 11/16

2 15/16

3 1/4

Approximate diameter of union

1 7/8

1 7/8

2 1/16

2 7/8

3 1/4

3 7/8

4 7/8

5 1/2

6

6 1/2

TABLE III
NPT (METRIC) THREADS
SIZE

5

4

3 1/2

3
(M75)

2 1/2
(M63)

2
(M50)

1 1/2
(M40)

1 1/4
(M32)

1
(M25)

3/4
(M20)

1/2
(M16)

1/16 - 3/8

1/16-3/8
NPT

4 3/8

3 5/8

3 3/8

3

2 5/8

2 3/8

2

1 7/8

1 5/8

1 3/8

1 1/4

1 1/8

1/2
(M16)

4 3/8

3 5/8

3 3/8

3

2 5/8

2 3/8

2

1 7/8

1 5/8

1 3/8

1 1/4

3/4
(M20)

4 1/2

3 3/4

3 1/2

3 1/8

2 3/4

2 1/2

2 1/8

2

1 3/4

1 1/2

1
(M25)

4 5/8

3 7/8

3 5/8

3 1/4

2 7/8

2 3/4

2 1/4

2 1/8

1 7/8

1 1/4
(M32)

4 7/8

4 1/8

3 7/8

3 1/2

3 1/8

2 7/8

2 1/2

2 3/8

1 1/2
(M40)

5

4 1/4

4

3 5/8

3 1/4

3

2 5/8

2
(M50)

5 3/8

4 3/4

4 1/2

4

3 5/8

3 3/8

2 1/2
(M63)

5 1/2

4 7/8

4 5/8

4 1/4

3 7/8

3
(M75)

5 7/8

5 1/4

5

4 5/8

3 1/2

6 1/4

5 3/4

5 1/2

4

6 7/8

6

5

7 3/8

This information is compiled from data which we believe is reliable and is given
in good faith. Since the methods of application and conditions under which our
products are used are beyond our control, we are not able to guarantee the
application and/or use of same. The user assumes all risks and liability in
connection with the application and use of our products.

6A–14

Note: All dimensions are in inches.
The Adalet engineering department is available to provide custom
explosionproof enclosures for your products.
226
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com

15599 Sec.6 12/9/01 11:11 AM Page 227
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz

Explosionproof Enclosures With Threaded Cover
METER & INSTRUMENT HOUSINGS
EXPLOSIONPROOF AND DUST-TIGHT
DRILLING & TAPPING LAYOUT INSTRUCTIONS
Consult factory for extensive machining options, i.e.
mounting of operators, thread type and size thru wall, mounting pans.
Layout data sheets available.
MINIMUM DISTANCE BETWEEN CENTERS OF AUXILIARY DEVICES AND CONDUIT ENTRIES
SIZE

5
NPSM

4
NPSM

3 1/2
NPSM

3
NPSM

2 1/2
NPSM

2
NPSM

1 1/2
NPSM

1 1/4
NPSM

1
NPSM

3/4
NPSM

1/4-3/8
NPSM

1/4-1 UN

1/16-3/8
NPT

4 3/8

3 5/8

3 3/8

3

2 5/8

2 3/8

2

1 7/8

1 5/8

1 3/8

1 1/4

1 1/8

1/2NPT
(M16)

4 3/8

3 5/8

3 3/8

3

2 5/8

2 3/8

2

1 7/8

1 5/8

1 3/8

1 1/4

3/4 NPT
(M20)

4 1/2

3 3/4

3 1/2

3 1/8

2 3/4

2 1/2

2 1/8

2

1 3/4

1 1/2

1 NPT
(M25)

4 5/8

3 7/8

3 5/8

3 1/4

2 7/8

2 3/4

2 1/4

2 1/8

1 7/8

1 1/4 NPT
(M32)

4 7/8

4 1/8

3 7/8

3 1/2

3 1/8

2 7/8

2 1/2

2 3/8

1 1/2 NPT
(M40)

5

4 1/4

4

3 5/8

3 1/4

3

2 5/8

5 3/8

4 3/4

4 1/2

4

3 5/8

3 3/8

5 1/2

4 7/8

4 5/8

4 1/4

3 7/8

3 NPT
(M75)

5 7/8

5 1/4

5

4 5/8

3 1/2
NPT

6 1/4

5 3/4

5 1/2

4
NPT

6 7/8

6

5
NPT

7 3/8

2 NPT
(M50)
2 1/2 NPT
(M63)

MINIMUM DISTANCE BETWEEN CENTERS OF AUXILIARY DEVICES
5
NPSM

4
NPSM

3 1/2
NPSM

3
NPSM

2 1/2
NPSM

2
NPSM

1 1/2
NPSM

1 1/4
NPSM

1
NPSM

3/4
NPSM

1/4-3/8
NPSM

1/4-1 UN

1/4-1 UN

4 3/8

3 5/8

3 3/8

3

2 5/8

2 3/8

2

1 7/8

1 5/8

1 3/8

1 1/4

1 1/8

1/4-3/8
NPSM

4 3/8

3 5/8

3 3/8

3

2 5/8

2 3/8

2

1 7/8

1 5/8

1 3/8

1 1/4

3/4
NPSM

4 1/2

3 3/4

3 1/2

3 1/8

2 3/4

2 1/2

2 1/8

2

1 3/4

1 1/2

1
NPSM

4 5/8

3 7/8

3 5/8

3 1/4

2 7/8

2 3/4

2 1/4

2 1/8

1 7/8

1 1/4
NPSM

4 7/8

4 1/8

3 7/8

3 1/2

3 1/8

2 7/8

2 1/2

2 3/8

1 1/2
NPSM

5

4 1/4

4

3 5/8

3 1/4

3

2 5/8

2
NPSM

5 3/8

4 3/4

4 1/2

4

3 5/8

3 3/8

2 1/2
NPSM

5 1/2

4 7/8

4 5/8

4 1/4

3 7/8

3
NPSM

5 7/8

5 1/4

5

4 5/8

3 1/2
NPSM

6 1/4

5 3/4

5 1/2

4
NPSM

6 7/8

6

5
NPSM

7 3/8

6A–15

SIZE

227
ADALET Enclosure Systems • Designing Our Products Around Yours

SM

T: 216.267.9000 • F: 216.267.1681 • info@adalet.com • www.adalet.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 126
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:9fdea4ca-3c6b-4b7c-ae7e-011aa2828297
Modify Date                     : 2006:05:02 13:59:25-04:00
Create Date                     : 2003:04:17 07:58:33-03:00
Metadata Date                   : 2006:05:02 13:59:25-04:00
Document ID                     : uuid:f2ee7e97-c04b-41d6-bdb6-9e1312283381
Format                          : application/pdf
Title                           : Adalet NCAT01 D Industrial Electrical And Explosionproof Enclosure Systems
Description                     : Section 8B
Creator                         : Rob Clausing
Author                          : Rob Clausing
Subject                         : Section 8B
Producer                        : Acrobat Distiller 4.05 for Macintosh
EXIF Metadata provided by EXIF.tools

Navigation menu