106104 Catalog

2014-11-11

: Pdf 106104-Catalog 106104-Catalog 781810 Batch12 unilog

Open the PDF directly: View PDF PDF.
Page Count: 36

Download106104-Catalog
Open PDF In BrowserView PDF
BURNDY® Products

Substation — Bolted

TABLE OF CONTENTS
COPPER SUBSTATION
Introduction . . . . . . . . . . . . . . . L-3

Type HFBW
Bar Clamp . . . . . . . . . . . . . . . L-13

Type NT
Tube to Tube . . . . . . . . . . . . . . L-4

Type HFB-P1
Bar Clamp . . . . . . . . . . . . . . . L-14

Type NSNT/NHNT
Tube to Cable . . . . . . . . . . . . . L-5

Type HFB-N
Tap Pad Adapter . . . . . . . . . . L-15

Type NSNT/NHNT
Cable to Cable . . . . . . . . . . . . L-6

Type NA
Tube to Flat . . . . . . . . . . . . . . L-16

Type VT
Cable to Cable . . . . . . . . . . . . L-7

Type XA
Tube to Flat, Expandable . . . . L-16

Type NS
Tube to Tube . . . . . . . . . . . . . . L-7

Type NAS/NAH
Cable to Flat (Terminal) . . . . . L-17

Type XP
Tube to Tube . . . . . . . . . . . . . . L-8

W

U

B
T

H

J

Type N2AH
Two Cables to Flat . . . . . . . . . L-18

L

Type B
Flexible Braid Jumper. . L-8 - L-11

Type VA, VVA
Cable to Flat (Terminal) . . . . . L-19

Type B Assembly Components
Expansion Coupler . . . . . . . . L-12

Type UH
Bus Support, Tube . . . . . . . . . L-20

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

L-1

BURNDY® Products

Substation — Bolted

TABLE OF CONTENTS
Type UHR
Bus Support, Tube or Cable . L-20

Type NS-A
Tube to Tube . . . . . . . . . . . . . L-28

Types LH, LHR
Bus Support, Tube or Cable . L-21

Type NA-A
Tube to Flat . . . . . . . . . . . . . . L-29

Type NDR
Stud Connector, Cable,
Tube, Flat Bar. . . . . . . . . . . . L-22

Type XA-A
Tube to Flat . . . . . . . . . . . . . . L-29

Type FD
Stud Connector, Stud to
Flat Bar. . . . . . . . . . . . . . . . . L-23
Type QGFL
Bar Tap, Cable to Flat . . . . . . L-24
Type FCB
Transformer Tap Adapter . . . . L-24
L-2

(Continued)

Type E-C-G
Transformer Tap Adapter . . . . L-25

Type NBC-A
Tube to Flat . . . . . . . . . . . . . . L-30
Type NAR-A
Cable to Flat . . . . . . . . . . . . . L-31
Type UHG-A
Bus Support, Tube . . . . . . . . . L-32
Type UHKR-A
Bus Support, Tube or Cable . L-32
Type LB-A
End Cap, Aluminum Tube . . . L-33

Type FN . . . . . . . . . . . . . . . . L-25
ALUMINUM SUBSTATION
Introduction . . . . . . . . . . . . . . L-26
Type NNT-A
Tube to Tube . . . . . . . . . . . . . L-27

Type WAS-A
Terminal Connector . . . . . . . . L-34
Type WASC-A-N
Centerformed Terminal . . . . . L-35
Type WG-A
Weldment Ground Stud . . . . . L-36

Type NNTR-A
Tube to Cable, Cable to
Cable... . . . . . . . . . . . . L-27 - L-28

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

COPPER
SUBSTATION
CONNECTORS

N-Line connectors are two-piece copper
alloy castings assembled with DURIUM™
(silicon bronze) hex bolts, nuts and washers.
They are available for connecting tube or
cable.

INTRODUCTION
BURNDY® electrical connectors are
designed to be installed with a minimum of
effort, to run cooler than the conductors
being joined and to provide optimum performance under all operating conditions.
To achieve this type of performance, extensive research and development time is spent
by BURNDY® engineers and scientists to
improve manufacturing techniques, materials
and designs. As these improvements become
available, they are incorporated into both
existing and new product lines. This continuous program of product innovation and
improvement insures that, as new and more
critical applications evolve, high quality connectors from BURNDY® will be available to
meet the need.

The Variline incorporates a modified V-bolt as
the clamping element for heavy-duty applications. This line is particularly suited for use
with flexible and extra flexible cables.

L-3

Flat pad connectors used to join cable or
tubing terminals to equipment studs.
A variety of bus supports are also available
for tube or cable. Some can be adjusted for
either a rigid or slide-fit by rotating the
clamping cap 180°.
Expansion connectors are used to absorb
the stress imposed on the bus by settling
ground, thermal expansion and shocks, as in
circuit breaker operations. The flexible elements are flat-tinned, copper braid, with sufficient cross sectional area to carry the rated
current of the conductors being joined.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

TYPE NT
T-CONNECTOR
FOR COPPER TUBE TO TUBE
High copper alloy T-Connector for tubing run
and tap. Slots between bolts provide independent high-pressure areas of contact.
One-wrench installation.

Catalog
Number
NT1414
NT1514
NT1515
NT1614
NT1615
NT1616
NT1714
NT1717
NT1818
NT2020
NT2222

Conductor
Run ‘A’

Tap ‘AA’

3/4
1
1

3/4
3/4
1
3/4
1
1-1/4
3/4
1-1/2
2
3
4

1-1/4
1-1/2
2
3
4

B

H

J

L

3/8

4-1/8
4-3/8
4-1/2

2
2

2-1/8
2-1/2

2-3/4
2
2-3/4
3-1/8
4-3/8
5-1/2

2-5/8
2-3/4
3-3/8
4-5/8
5-3/4

4-3/4
1/2
3/8
1/2
5/8

5-3/4
5-1/8
6-1/8
6-3/4
8-5/8
9-7/8

L-4

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE NSNT/NHNT
T-CONNECTOR
FOR COPPER TUBE
TO CABLE
High copper alloy T-Connector for joining
copper tubing run to a wide range of copper
tap cable. Tap utilizes reversible cap to
achieve large conductor range and the connector is designed for one-wrench installation.

Catalog
Number

Run
IPS
or
EHPS A

NSNT1329
NHNT1329
NSNT1429
NHNT1429
NSNT1434
NHNT1434
NSNT1529
NHNT1529

3/4⬙ (1.050 Dia.)

NHNT1534

1⬙ (1.315 Dia.)

1/2⬙ (.840 Dia.)

NHNT1540
NSNT1629
NHNT1629
NHNT1634
1-1/4⬙ (1.660 Dia.)
NHNT1640
NHNT1644
NHNT1729
NHNT1734
1-1/2⬙ (1.900 Dia.)
NHNT1740
NHNT1744
NHNT1829
NHNT1834
NHNT1840

2⬙ (2.375 Dia.)

NHNT1844
NHNT1846
NHNT1929
NHNT1934
NHNT1940

2-1/2⬙ (2.875 Dia.)

NHNT1944
NHNT1946
NHNT2044

3⬙ (3.500 Dia.)

Commercial Copper Cable Range
Complete ➀
Small
Large
Tap Cable
Tap
Tap
Range AA
Groove
Groove
6 Sol. (.162 Dia.) to
250 kcmil (.575 Dia.)
6 Sol. (.162 Dia.) to
250 kcmil (.575 Dia.)
1/0 Sol. (.325 Dia.) to
500 kcmil (.813 Dia.)
6 Sol. (.162 Dia.) to
250 kcmil (.575 Dia.)
1/0 Sol. (.325 Dia.) to
500 kcmil (.813 Dia.)
2/0 Str. (.420 Dia.) to
800 kcmil (1.031 Dia.)
6 Sol. (1.62 Dia.) to
250 kcmil (.575 Dia.) to
1/0 Sol. (.325 Dia.) to
500 kcmil (.813 Dia.)
2/0 Str. (.420 Dia.) to
800 kcmil (1.031 Dia.)
4/0 Str. (.529 Dia.) to
1000 kcmil (1.152 Dia.)
6 Sol. (.162 Dia.) to
250 kcmil (.575 Dia.)
1/0 Sol. (.325 Dia.) to
500 kcmil (.813 Dia.)
2/0 Str. (.420 Dia.) to
800 kcmil (1.031 Dia.)
4/0 Str. (.529 Dia.) to
1000 kcmil (1.152 Dia.)
6 Sol. (.162 Dia.) to
250 kcmil (.575 Dia.)
1/0 Sol. (.325 Dia.) to
500 kcmil (.813 Dia.)
2/0 Str. (.420 Dia.) to
800 kcmil (1.031 Dia.)
4/0 Str. (.529 Dia.) to
1000 kcmil (1.152 Dia.)
1000 kcmil (1.152 Dia.) to
1500 kcmil (1.412 Dia.)
6 Sol. (.162 Dia.) to
250 kcmil (.575 Dia.)
1/0 Sol. (.325 Dia.) to
500 kcmil (.813 Dia.)
2/0 Str. (.420 Dia.) to
800 kcmil (1.031 Dia.)
4/0 Str. (.529 Dia.) to
1000 kcmil (1.152 Dia.)
1000 kcmil (1.152 Dia.) to
1500 kcmil (1.412 Dia.)
4/0 Str. (.529 Dia.) to
1000 kcmil (1.152 Dia.)

6 Sol. (.162 Dia.) to
1/0 Str. (.372 Dia.)
6 Sol. (.162 Dia.) to
1/0 Str. (.372 Dia.)
1/0 Sol. (.325 Dia.) to
4/0 Str. (.529 Dia.)
6 Sol. (.162 Dia.) to
1/0 Str. (.372 Dia.)
1/0 Sol. (.325 Dia.) to
4/0 Str. (.529 Dia.)
2/0 Str. (.420 Dia.) to
500 kcmil (.813 Dia.)
6 Sol (.162 Dia.) to
1/0 Str. (.372 Dia.)
1/0 Sol. (.325 Dia.) to
4/0 Str. (.529 Dia.)
2/0 Str. (.420 Dia.) to
500 kcmil (.813 Dia.)
4/0 Str. (.529 Dia.) to
750 kcmil (.998 Dia.)
6 Sol. (.162 Dia.) to
1/0 Str. (.372 Dia.)
1/0 Sol. (.325 Dia.) to
4/0 Str. (.529 Dia.)
2/0 Str. (.420 Dia.) to
500 kcmil (.813 Dia.)
4/0 Str. (.529 Dia.) to
750 kcmil (.998 Dia.)
6 Sol. (.162 Dia.) to
1/0 Str. (.372 Dia.)
1/0 Sol. (.325 Dia.) to
4/0 Str. (.529 Dia.)
2/0 Str. (.420 Dia.) to
500 kcmil (.813 Dia.)
4/0 Str. (.529 Dia.) to
750 kcmil (.998 Dia.)
—
6 Sol. (.162 Dia.) to
1/0 Str. (.372 Dia.)
1/0 Sol. (.325 Dia.) to
4/0 Str. (.529 Dia.)
2/0 Str. (.420 Dia.) to
500 kcmil (.813 Dia.)
4/0 Str. (.529 Dia.) to
750 kcmil (.998 Dia.)
—
4/0 Str. (.529 Dia.) to
750 kcmil (.998 Dia.)

2/0 Str. (.420 Dia.) to
250 kcmil (.575 Dia.)
2/0 Str. (.420 Dia.) to
250 kcmil (.575 Dia.)
250 kcmil (.575 Dia.) to
500 kcmil (.813 Dia.)
2/0 Str. (.420 Dia.) to
250 kcmil (.575 Dia.)
250 kcmil (.575 Dia.) to
500 kcmil (.813 Dia.)
500 kcmil (.813 Dia.) to
800 kcmil (1.03 Dia.)
2/0 Str. (.420 Dia.) to
250 kcmil (.575 Dia.)
250 kcmil (.575 Dia.) to
500 kcmil (.813 Dia.)
500 kcmil (.813 Dia.) to
800 kcmil (1.031 Dia.)
750 kcmil (.998 Dia.) to
1000 kcmil (1.152 Dia.)
210 Str. (.420 Dia.) to
250 kcmil (.575 Dia.)
250 kcmil (.575 Dia.) to
500 kcmil (.813 Dia.)
500 kcmil (.813 Dia.) to
800 kcmil (1.031 Dia.)
750 kcmil (.998 Dia.) to
1000 kcmil (1.152 Dia.)
2/0 Str. (.420 Dia.) to
250 kcmil (.575 Dia.)
250 kcmil (.575 Dia.) to
500 kcmil (.813 Dia.)
500 kcmil (.813 Dia.)
800 kcmil (1.031 Dia.)
750 kcmil (.998 Dia.) to
1000 kcmil (1.152 Dia.)
1000 kcmil (1.152 Dia.) to
1500 kcmil (1.412 Dia.)
2/0 Str. (.420 Dia.) to
250 kcmil (.575 Dia.)
250 kcmil (.575 Dia.) to
500 kcmil (.813 Dia.)
500 kcmil (.813 Dia.) to
800 kcmil (1.031 Dia.)
750 kcmil (.998 Dia.) to
1000 kcmil (1.152 Dia.)
1000 kcmil (1.152 Dia.) to
1500 kcmil (1.412 Dia.)
750 kcmil (.998 Dia.) to
1000 kcmil (1.152 Dia.)

B

B-B

H

2.00
2.25
2.00
2.25
2.00
2.25
2.00

2.38
2.62
2.38
2.62
2.38
2.62
2.38

2.00
2.32
2.00
2.32
2.10
2.42
2.00
2.57

2.25

2.62

2.57

“J”
Dia.

L

W

Y

3/8⬙-16
1/2⬙-13
3/8⬙-16
1/2⬙-13
3/8⬙-16
1/2⬙-13
3/8⬙-16

5.08
5.82
5.08
5.82
5.08
5.82
5.34

1.96
2.44
1.96
2.44
2.20
2.56
1.96
2.44

3.89
4.38
3.89
4.38
3.89
4.38
4.02

5.92
1/2⬙-13

2.60
2.00

2.38

2.62
2.69

2.37
2.57

3/8⬙-16

2.60

2.78

5.78

1.96 4.24
2.44

6.32

2.56

4.63

2.78

2.69

6.58

2.70
2.62

4.43

—

2.68
2.88

2.56

L-5

2.90 4.89
2.44

2.70

6.76

2.56 4.85

2.69
2.78
2.88

2.78

2.80

7.02

2.90 5.11
2.44

2.62

3.06

1/2⬙-13

7.44

2.69

2.56 5.19
2.78

2.88

3.06

7.70

2.90 5.45

3.06

3.23

7.88

3.16 5.63
2.44

2.62

8.06
3.64

2.56 5.50
2.78

2.69
2.88

8.32

2.90 5.76

3.06

8.50

3.16 5.94

8.95

2.90 6.07

5.75

4.26

① Complete cable range may be accommodated by reversing
cap.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

TYPE NSNT/NHNT
T-CONNECTOR
FOR COPPER CABLE
TO CABLE
High copper alloy reversible T-Connector for
joining a wide range of run and tap cables.
Connector is designed for one-wrench installation. “S” standard 3/8⬙ hardware and
“H” heavy duty 1/2⬙ hardware.

Small
Run
Groove

6 Sol. (.162 Dia.)
to 250 kcmil
(.575 Dia.)
1/0 Sol.
(.325 Dia.)
to 500 kcmil
(.813 Dia.)

6 Sol. (.162 Dia.)
to 1/0 Str.
(.372 Dia.)
1/0 Sol.
(.325 Dia.)
to 4/0 Str.
(.529 Dia.)

2/0 Str. (.420 Dia.)
to 250 kcmil
(.575 Dia.)
250 kcmil
(.575 Dia.)
to 500 kcmil
(.813 Dia.)

4/0 Str.
(.529 Dia.)
to 1000 kcmil
(1.152 Dia.)

4/0 Str.
(.529 Dia.)
to 750 kcmil
(.998 Dia.)

750 kcmil
(.998 Dia.)
to 1000 kcmil
(1.152 Dia.)

500 kcmil
(.813 Dia.)
to 2000 kcmil
(1.632 Dia.)

500 kcmil
(.813 Dia.)
to 1500 kcmil
(1.412 Dia.)

1500 kcmil
(1.412 Dia.)
to 2000 kcmil
(1.632 Dia.)

Catalog
Number
NSNT2929
NHNT2929
NSNT3429
NHNT3429
NSNT3434
NHNT3434

Commercial Copper Cable Range
Complete
Large
Tap Cable
Run
Range
Groove
AA ➀

Complete
Run Cable
Range
A➀

NHNT4429

NHNT4434

NHNT4440

NHNT4444

L-6

NHNT4834

NHNT4840

NHNT4844

NHNT4846

NHNT4848

Small
Tap
Groove

Large
Tap
Groove

6 Sol. (.162 Dia.)
to 250 kcmil
(.575 Dia.)

6 Sol. (.162 Dia.)
to 1/0 Str.
(.372 Dia.)

2/0 Str. (.420 Dia.)
to 250 kcmil
(.575 Dia.)

1/0 Sol. (.325 Dia.)
to 500 kcmil
(.813 Dia.)
6 Sol. (.162 Dia.)
to 250 kcmil
(.575 Dia.)
1/0 Sol. (.325 Dia.)
to 500 kcmil
(.813 Dia.)
2/0 Str. (.420 Dia.)
to 800 kcmil
(1.031 Dia.)
4/0 Str. (.529 Dia.)
to 1000 kcmil
(1.152 Dia.)
1/0 Sol. (.325 Dia.)
to 500 kcmil
(.813 Dia.)
2/0 Str. (.420 Dia.)
to 800 kcmil
(1.031 Dia.)
4/0 Str. (.529 Dia.)
to 1000 kcmil
(1.152 Dia.)
1000 kcmil (1.152 Dia.)
to 1500 kcmil
(1.412 Dia.)
500 kcmil (.813 Dia.)
to 2000 kcmil
(1.632 Dia.)

1/0 Sol. (.325 Dia.)
to 4/0 Str.
(.529 Dia.)
6 Sol. (.162 Dia.)
to 1/0 Str.
(.372 Dia.)
1/0 Sol. (.325 Dia.)
to 4/0 Str.
(.529 Dia.)
2/0 Str. (.420 Dia.)
to 500 kcmil
(.813 Dia.)
4/0 Str. (.529 Dia.)
to 750 kcmil
(.998 Dia.)
1/0 sol. (.325 Dia.)
to 4/0 Str.
(.529 Dia.)
2/0 Str. (.420 Dia.)
to 500 kcmil
(.813 Dia.)
4/0 Str. (.529 Dia.)
to 750 kcmil
(.998 Dia.)

250 kcmil (.575 Dia.)
to 500 kcmil
(.813 Dia.)
2/0 Str. (.420 Dia.)
to 250 kcmil
(.575 Dia.)
250 kcmil (.575 Dia.)
to 500 kcmil
(.813 Dia.)
500 kcmil (.813 Dia.)
to 800 kcmil
(1.031 Dia.)
750 kcmil (.998 Dia.)
to 1000 kcmil
(1.152 Dia.)
250 kcmil (.575 Dia.)
to 500 kcmil
(.813 Dia.)
500 kcmil (.813 Dia.)
to 800 kcmil
(1.031 Dia.)
750 kcmil (.998 Dia.)
to 1000 kcmil
(1.152 Dia.)
1000 kcmil (1.152 Dia.)
—
to 1500 kcmil
(1.412 Dia.)
500 kcmil (.813 Dia.) 1500 kcmil (1.412 Dia.)
to 1500 kcmil
to 2000 kcmil
(1.412 Dia.)
(1.632 Dia.)

① Complete cable range may be accommodated by reversing cap.

Catalog
Number
NSNT2929
NHNT2929
NSNT3429
NHNT3429
NSNT3434
NHNT3434
NHNT4429
NHNT4434
NHNT4440
NHNT4444
NHNT4834
NHNT4840
NHNT4844
NHNT4846
NHNT4848

B

B-B

H

“J” DIA.

L

W

Y

2.38
2.62
2.38
2.62
2.38
2.62

2.38
2.62
2.38
2.62
2.38
2.62

1.75
2.07
2.00
2.32
2.00
2.32

3/8⬙-16
1/2⬙-13
3/8⬙-16
1/2⬙-13
3/8⬙-16

4.60
5.32
4.84
5.44
4.84
5.38

1.96
2.44
1.96
2.44
2.20
2.56
2.44
2.56
2.78
2.90
2.56
2.78
2.90
3.16
3.38

3.62
4.10
3.74
4.16
3.74
4.10

2.88

2.62
2.88

3.25

Canada: 1-800-387-6487

2.62
2.88
3.06
3.25

5.78

2.57
1/2⬙-13

6.03
6.26

3.07

6.51
6.76
6.94

www.burndy.com

4.33
4.58
4.57
4.82
5.07
5.25

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE VT
T-CONNECTOR
FOR COPPER CABLE
TO CABLE
High copper alloy T-Connector for cable run,
cable tap, V-bolt clamping elements accommodate large range of cable and are particularly suited for extra flexible cable. Onewrench installation.

Catalog
Number

Run - A

Conductor
Tap - AA

H

L

W

VT2C2C
VT2525
VT2825
VT2828
VT3025
VT3030
VT3425
VT3428
VT3430
VT3434
VT4040
VT4425
VT4428
VT4834

8 Sol. - 2 Str.
6 Sol. - 1/0 Str.
1/0 Str. - 4/0 Str.
1/0 Str. - 4/0 Str.
1/0 Str. - 300
1/0 Str. - 300
300 - 500
300 - 500
300 - 500
300 - 500
500 - 800
750 - 1000
750 - 1000
1500 - 2000

8 Sol. - 2 Str.
6 Sol. - 1/0 Str.
6 Sol. - 1/0 Str.
1/0 Str. - 4/0 Str.
6 Sol. - 1/0 Str.
1/0 Str. - 300
6 Sol. - 1/0 Str.
1/0 Str. - 4/0 Str.
1/0 Str. - 300
300 - 500
500 - 800
6 Sol. - 1/0 Str.
1/0 Str. - 4/0 Str.
300 - 500

1-3/8

2-3/8
2-5/8

1

1-5/8

3-1/8

1-7/8

3-3/8
3-3/4
3-1/2
3-5/8
3-3/4
4-1/2
4-3/8
4-1/8
5-1/4

2-3/8
2-5/8
2-7/8
4-1/4

1-1/4
1-3/4
1-1/8
2
1-1/4
1-3/4
2
2-1/4
2-5/8
1-1/4
1-3/4
2-1/4
L-7

TYPE NS

Fig. 2

COUPLER
FOR COPPER TUBE TO TUBE
High copper alloy coupler for joining equal
sizes of tube end to end. Slots between bolts
provide independent high pressure areas of
contact. One-wrench installation.

Fig. 1
Catalog
Number

Conductor - A

Conductor - B

NS1313
NS1414HC
NS1515
NS1616HC
NS1717
NS1818
NS1919
NS2020
NS2121
NS2222

1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4

1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4

J

L

3/8

3-1/4
4
4-1/4

1/2

5-3/4

Fig.
No.
1

2
5/8

7-1/4
8
8-1/2

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

TYPE XP
EXPANSION COUPLER
FOR COPPER TUBE TO TUBE
High alloy copper expansion coupler for joining equal size tube on end. Extra flexible
tinned copper braid allows longitudinal
movement of the tube. Type XP has alignment guide. One-wrench installation.

Catalog Number
Standard IPS
With Guide

Conductor

H

J

L

XP1818
XP2222

2
4

7
9-1/8

1/2
5/8

12
13-5/8

TYPE B
L-8

FLEXIBLE COPPER
BRAID JUMPER
Flexible copper braid jumpers designed to
take up linear expansion and contraction,
compensate for misalignment and absorb
vibratory movement of electrical equipment
and devices.
Made of flat, extra flexible, tinned, pure
copper braid, with unplated, seamless, pure
copper ferrules formed into a rectangular
shape on each end.
Last two numbers in catalog number indicate
total length of braid in inches, e.g., BD12N or
BD12 is standard 12⬙ long braid jumper. All
braids are available in 12⬙, 18⬙, and 24⬙
lengths.
Other lengths, plating and drilling are available. Refer to factory.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

FLEXIBLE COPPER
BRAID JUMPER
Copper braid is made of tinned, pure copper
wire woven and flattened into a rectangular
shape for greater flexibility. Seamless, pure
copper ferrules are formed and assembled
on each end to provide appropriate
contact surfaces.
Braid is used extensively to compensate for
expansion and contraction of moving parts
and for thermal movement of rigid devices;
to prevent breakage of insulators or bushings
or equipment because of misalignment during settling of substation foundations; to
absorb shock and vibration of operating
equipment; and to provide flexible current
carrying leads between moving parts of
heavy machinery or equipment.

CURRENT CARRYING
CAPACITY
Flexible copper braid has generally better
heat dissipation properties than flat bar,
cable or other conductors, and therefore can
be expected to have a greater current carrying capacity for a given cross-sectional area.
This is due to its greater surface area resulting from the woven construction of fine
strands. However, ventilation, due to the vertical convection current of air, is appreciably
better when the long axis of the braid is vertical rather than horizontal, so that the long
sides of the braid, rather than the edges, are
exposed to the moving air. This is particularly true when spaced braids are used in
multiple as can be seen by comparing
Figures 1 and 2.

Fig. 1

BULK BRAID
Bulk braid can be ordered with a minimum
order quantity of 10 feet. Specify feet in number of inches.
Example: 10 feet of 190 ampere braid is
Catalog No. BB077L120.
INDOOR
EQUIV
APPROX
RATING CIRCULAR CAT
WEIGHT
AREA
NO.
PER* FT
AMPS
190
77,184 BB077L
.24
340
153,700 BB154L
.49
360
231,552 BB226L
.76
415
300,000 BB300L
1.06

Fig. 2

L-9

To take full advantage of ventilation, the
cooling convection current of air should be
permitted to flow freely between the braids.
Therefore, if possible, the braids should be
spaced apart, rather than bunched together,
as illustrated in Figure 3. The effectiveness of
spacing is, or course, greater when the
braids are in a vertical position.

Fig. 3
Cooling Due to Convection Currents Much
More Effective with Spaced Braid

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

FLEXIBLE
COPPER BRAID
CUSTOM DESIGNS
Flexible copper braid offers an economical
and efficient means of protecting electrical
equipment from the potentially harmful
effects of shock and vibration, terminal
expansion, movement of components and
misalignment that may occur during the
service life of the equipment.
Many varieties of braid are required to meet
those needs which we can build to your
specifications.
We also offer engineering assistance in the
selection of the most appropriate standard
or custom braid configuration for your
application.

CUSTOM VARIATIONS
Drilling
* Undrilled
* Elongated (slotted) holes
* Special hole patterns and location
* Metric
* NEMA
Plating
* Tin
* Silver
* Nickel
L-10
* Unplated
Length
* Jumper (overall)
* Ferrule(s) contact
Insulated (covered)
* Tubular
* Heat shrink
Split Braid Assemblies
* Stacked
* Side-by-side
Multiple Ferrules
Preformed Configurations
* Offset contact surfaces
* Angular (e.g., 90°, 180°) bends
* Ferrule contact surfaces rotated 90°
on braid axis
Combined Braid Assemblies
Combined Connector - Braid Assemblies
Ferrule Variations
* Belled/unbelled
* Width/thickness
* Contact length
* Special shaping
* Bent at angle °
High Ampacity Requirements

Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE B
FLEXIBLE COPPER
BRAID JUMPER

Catalog
Number
BD12 †
BD12N** †
BD18 †
BD18N** †
BD24 †
BD24N** †
BE12 †
BE12N** †
BE18 †
BE18N** †
BE24 †
BE24N** †
BF12 †
BF12N** †
BF18 †
BF18N** †
BF24 †
BF24N** †
BG12
BG12N**
BG18
BG18N**
BG24
BG24N**
B2D12 †
B2D12N** †
B2E12
B2E12N**
B2F12
B2F12N**
B2G12N**
B3D12 †
B3D12N** †
B3E12
B3E12N**
B3F12
B3F12N**
B3G12
B3G12N**
B4D12
B4D12N**
B4E12
B4E12N**
B4F12
B4F12N**
B4G12N**

Number of
Braids in
Ferrules

1

C

D

E

K

L

.94

2.50
3.00
2.50
3.00
2.50
3.00

1.25
1.75
1.25
1.75
1.25
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.25
1.75
1.50
1.75
1.50
1.75
1.75
1.25
1.75
1.50
1.75
1.50
1.75
1.50
1.75
1.25
1.75
1.50
1.75
1.50
1.75
1.75

.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.44
.56
.56

12
12
18
18
24
24
12
12
18
18
24
24
12
12
18
18
24
24
12
12
18
18
24
24
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12

1

1.50

3.00

1

1.19

3.00

1

1.50

3.00

.94
2

1.62
1.38
1.50
1.19
1.64

3
1.44
1.69
1.19
4

1.64
1.50
1.69

* This rating may vary with ambient conditions, orientation
of the braid and other service conditions.
** Tongue drilled per NEMA Standard - 9/16⬙ diameter for
1/2⬙ diameter bolts on 13/4 C to C.

2.50
3.00
3.00
3.00
3.00
3.00
3.00
2.50
3.00
3.00
3.00
3.00
3.00
3.00
3.00
2.50
3.00
3.00
3.00
3.00
3.00
3.00

Approximate
Ampere Rating*
Indoor
Outdoor

N

T

.62

.13

190

225

.17

340

405

.25

360

430

.25

415

495

.75
.62
.75
.62
.75
.62
.75
.62
.75
.62
.75
.62
.75
.62
.75
.62
.75
.62
.62
.62
.75
.62
.75
.62
.62
.62
.62
.75
.62
.75
.62
.75
.62
.62
.62
.75
.62
.75
.62
.62

L-11
.25

380

455

.25

530

635

.38

600

720

.50

700

840

.25

470

560

.31

700

840

.56

820

980

.69

960

1150

.32

600

720

.38

850

1020

.78

1000

1200

.94

1200

1440

Note: All sizes are listed to UL467 and specific sizes (†) are
certified to CSA C22.2, No. 41 Grounding and Bonding
Equipment Standards. Equivalent sizes may be designated
by suffix letters representing variations in length, mounting configurations, pad size and finish. Contact factory for
details.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

TYPE B
EXPANSION COUPLER
ASSEMBLY COMPONENTS

Fig. 1

FOR COPPER BAR
To build your own expansion coupler assembly for single or multiple flat bar(s), using
extra flexible tinned copper braid (shown on
page 9) and clamping hardware, the following table has been provided. The assembly
takes up longitudinal and lateral motion.

Conductor
Copper Bar
Width ➁
Number ➂

2

3
L-12

4

5

6

⑥
Approximate
Ampere Rating
Indoor
Outdoor

1
2
3

700
1100
1600

840
1320
1920

4

1800

2160

1
2
3
4
1
2
3
4
1
2
3
4
1

1000
1650
2000
2200
1350
2250
2700
3000
1600
2650
3200
3500
1900

1200
1980
2400
2640
1620
2700
3240
3600
1920
3180
3840
4200
2280

2

3150

3780

3
4

3800
4200

4560
5040

Fig. 2

Flexible
➃ Copper ➁
Braid Jumper
Qty.
Cat. No.
2
3
4
3
1
4
6
8
8
4
2
6
6
4
9
12
15
6
3
6
9
9

① Components ordered separately from BURNDY®.
② See page 11 for flexible copper braid jumper dimensions
and drilling.

③ Bars listed are 1/4⬙ thick. Multiple bars are spaced1/4⬙.
④ For two hole NEMA drilling in each ferrule add suffix letter “N”
to catalog number of braid jumper as shown on page 11.
EXAMPLE: B2E12 drilling is .44 dia. holes on 1.50⬙
centers.
B2E12N drilling is .56 dia. holes on 1.75⬙
centers.
When specifying NEMA drilling bolt diameter
in table must be changed from 38 to 50
(length is not changed).

Qty.

B2E12
BG12
B2E12
B3E12 ➄
BG12
B2E12
BG12
BG12
B2E12
B2E12
BG12
BG12
B3E12
B2E12
BG12
BG12
B2E12
B2E12
B3E12
BG12
BG12

4

Fig. 3

Expansion Coupler Assembly Components ➀
Silicon Bronze Clamping Hardware
Split
Bolts
Nuts
Lockwasher
Flat Washer
Cat. No.
Qty.
Cat. No.
Qty.
Cat. No.
Qty. Cat. No.
38X125HEB
38X175HEB
38X225HEB

4

4

8

8

8

16

Fig.
No.

1

38X250HEB

8

8
8
12

12

38X125HEB
38X175HEB
38X225HEB
38X250HEB
38X125HEB
38X225HEB
38X250HEB
38X325HEB
38X125HEB
38X175HEB
38X225HEB
38X275HEB
38X125HEB
38X175HEB

2
8

38CHEN

8

38SW

16

8

8

16

12

12

24

38FW

3
12

12

24

38X250HEB
38X325HEB

NOTE: Minimum length of each ferrule with NEMA drilling
is 3.00⬙.

⑤ Braid jumper ferrule (pad) thickness is larger than 1/4⬙

requiring assembly to outer contact surface(s) of multiple
(1/4⬙ spaced ) bars.
➅ These ratings may vary with ambient conditions, orientation of the braid and other service conditions.
⑦ For other combinations and configurations of flat bar
contact BURNDY®.
8. For UL/CSA listing see page 11.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE HFBW
BAR CLAMP
FOR COPPER BAR
The clamp assembly eliminates the need for
drilling the flat bar and is used in indoor and
outdoor applications.
The open web design provides a uniform
clamping pressure while minimizing the
weight of the connector.

Fig. 1

Catalog
Number *

Conductor
Run
Tap

HFBW86T20CG1
HFBW66T16CG1
HFBW64T17CG1
HFBW44T17CG1
HFBW43T10CG1
HFBW42T10CG1

8.0
6.0
6.0
4.0
4.0
4.0

6.0
6.0
4.0
4.0
3.0
2.0

Fig. 2

FEATURES

BENEFITS

• Web design cast copper body.
• Fully threaded yellow galvanized bolts with
split-lockwashers and nuts included.
• Flat bar accommodation molded into
body.

• Increased tortional resistance.
• Reduced weight.
• Simple installation.
• Easy identification.
L-13

Figure
Number

Standard
Maximum ‘Z’
Dimension

Total Number
of Flat
Bars (Standard
1/4⬙ Thick)

Bolt Size

W

L

2
2
2
2
2
1

5.00
4.00
4.25
4.25
2.50
2.50

20
16
17
17
10
10

5/8”-11
1/2”-13
1/2”-13
1/2”-13
3/8”-16
3/8”-16

8.13
7.75
5.75
5.68
4.42
3.54

10.13
7.75
7.75
5.68
5.42
5.55

Dimensions

* Catalog number based on standard maximum “Z”
dimension. Refer to your FCI representative for nonstandard “Z” dimensions.
Add TN suffix for tin plating (example: HFBW86T20CG1TN).
All dimensions in inches.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

TYPE HFB-P1
BAR CLAMP ASSEMBLY
COMPONENTS
FOR COPPER BAR
To build your own high strength clamp
assembly for multiple flat bar using type
HFB-P1 bar clamps & clamping hardware,
the following tables have been provided. The
clamp assembly eliminates the need for
drilling the flat bar and is used in indoor and
outdoor applications.

Bar Clamp
Catalog
Number
HFB33P1
HFB44P1
HFB63P1
HFB66P1
HFB88P1

One Clamp Half
Bus Bar
Run
Tap
‘A’
‘AA’

“J”
Bolt
Dia.

L

W

3.00
4.00
6.00
6.00
8.00

3/8
1/2
1/2
5/8
3/4

4.38
5.75
7.75
8.12
10.50

4.38
5.75
4.75
8.12
10.50

Copper
Bus Bar
Width (Inches)
Run-A
Tap-AA
L-14

3
4
6
6
8

Position for assembly
(2) Req’d
for assembly

3
4
3
6
8

3.00
4.00
3.00
6.00
8.00

Qty.

Bar Clamp
Cat. No.

2
2
2
2
2

HFB33P1
HFB44P1
HFB63P1
HFB66P1
HFB88P1

Bar Clamp
Assembly

Bar Clamp Assembly Components †
Silicon Bronze Clamping Hardware
Bolts**
Nuts
Qty.
Cat. No.
Qty.
Cat. No.
4
4
4
4
4

38 X (*) HEB
50 X (*) HEB
50 X (*) HEB
62 X (*) HEB
75 X (*) HEB

Split Lockwashers
Qty.
Cat. No.

4
4
4
4
4

38CHEN
50CHEN
50CHEN
62CHEN
75CHEN

4
4
4
4
4

38SW
50SW
50SW
62SW
75SW

When
Z=2.25*

When
Z=2.50*

When
Z=2.75*

When
Z=3.00*

4.00
4.50
4.50
4.50
5.00

4.50
4.50
4.50
5.00
5.00

4.50
5.00
5.00
5.00
5.50

5.00
5.00
5.00
6.00
5.50

† Ordered separately from BURNDY®.
* Z = Space between the bar clamp contact surfaces.
* *See table below when ordering assembly clamping bolts
to specify correct bolt length in Cat. #.

Clamp
Number

‘J’
Bolt Dia.

When
Z=1.25*

When
Z=1.50*

HFB33P1
HFB44P1
HFB63P1
HFB66P1
HFB88P1

3/8⬙(-16)
1/2⬙(-13)
1/2⬙(-13)
5/8⬙(-11)
3/4⬙(-10)

3.00
3.25
3.25
3.50
3.75

3.25
3.50
3.50
4.00
4.00

Bolt Length**
When
When
Z=1.75*
Z=2.00*
3.50
3.75
3.75
4.00
4.50

4.00
4.00
4.00
4.50
4.50

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE HFB-N
BAR CLAMP TAP PAD
ADAPTER
FOR COPPER BAR
High conductivity copper, tap pad adapter
provides a NEMA drilled contact pad when
assembled to the HFB-P1 clamps. Tap connections can be made from copper bus
bar(s) without drilling by bolting standard
mechanical or compression terminal pads
directly to the pre-drilled tap pad adapter.

Fig. 1
Fig. 2
❶ Use With ‘H’

Catalog
Number

Fig.
No.

A-C

E&F

L

N

Clamp Cat. No.

HFB33-4N
HFB44-4N
HFB66-6N

1
1
2

3.00
4.00
6.00

1.75
1.75
1.75

7.00
9.12
11.31

.62
1.12
1.12

HFB33P1
HFB44P1
HFB66P1

L-15

❶ ‘H’ Clamp (two required per assembly) and hardware
(as shown) not included with bar clamp tap pad, order
separately.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

TYPE NA
TERMINAL
FOR COPPER TUBE TO FLAT
High copper alloy terminal for joining copper
tube to a flat pad. Letter “N” on end of catalog number indicates pad drilled to NEMA
standards. One-wrench installation.

L-16

Catalog
Number
NA13-2N
NA14-2N
NA15-2N
NA15-4N
NA16-2N
NA16-4N
NA17-2N
NA17-4N
NA18-4N
NA19-4N
NA21-4N

Conductor

No. of
Holes
in Pad

C

1/2
3/4
1
1
1-1/4
1-1/4
1-1/2
1-1/2
2
2-1/2
3-1/2

2
2
2
4
2
4
2
4
4
4
4

1-1/2
1-5/8
1-7/8
3
2-1/4
3
2-1/2
3
3-1/8
3-1/4
4-3/8

D

3

E&F

H

J

1-3/4

1-3/4
2
2-1/8
2-1/8
2-5/8
2-5/8
2-3/4
2-3/4
3-1/
3-3/4
5

3/8
3/8
3/8
3/8
1/2
1/2
1/2
1/2
1/2
1/2
5/8

K

L

N

T

5/8

3/8
3/8
3/8
3/8
1/2
1/2
1/2
1/2
1/2
3/4
7/8

5-1/4

9/16
6

6-5/8

TYPE XA
EXPANSION TERMINAL
FOR COPPER TUBE TO FLAT
High copper alloy expansion terminal for
tube to flat. Provides for longitudinal movement of tubing. Extra flexible braid carries full
load of joint. One-wrench installation.

Catalog Number
Standard I.P.S.
With Guide
XA18-4N

Conductor

Number
of Holes
in Pad*

C

H

J

L

T

2

4

3

7

1/2

15-1/4

1/2

* Conforms to NEMA Standards

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE NAS/NAH
TERMINAL
FOR COPPER CABLE
High copper alloy reversible cap terminal for
joining a wide range of cable to equipment
pads. Tongue is side formed to provide
adequate clearance and terminal is designed
for one-wrench installation.

Fig. “B”

Fig. “A”

Fig. 1

Catalog
Number

Fig.
No.

NAS29-N
NAS29-2N
NAH29-2N
NAS29-34N
NAS34-N
NAS34-2N
NAH34-2N
NAS34-34N
NAH34-34N
NAS40-2N

1B
1D
1D
1E
1C
1A
1A
1E
1E
1A

NAH40-2N

1A

NAS40-34N
NAH40-34N
NAH40-44N
NAH44-2N
NAH44-34N
NAH44-44N
NAH46-2N

1E
1E
1
1A
1E
1
1A

NAH46-34N

1E

NAH46-44N
NAH48-2N

1
1A

NAH48-34N

1E

NAH48-44N

1

Complete
Cable Range
6 Sol. (.162 Dia.) to
250 kcmil (.575 Dia.)

Copper Cable Range
Small
Groove
6 Sol. (.162 Dia.) to
1/0 Str. (.373 Dia.)

2/0 Sol. (.365 Dia.) to
800 kcmil (1.031 Dia.)

1/0 Sol. (.325 Dia.) to
4/0 Str. (.529 Dia.)

2/0 Sol. (.365 Dia.) to
500 kcmil (.813 Dia.)

Fig. “E”

Fig. “D”

Large
Groove
2/0 Str. (.419 Dia.) to
250 kcmil (.575 Dia.)

B

250 kcmil (.575 Dia.) to
500 kcmil (.813 Dia.)

500 kcmil (.813 Dia.) to
800 kcmil (1.031 Dia.)

H

J Dia.

2.38

1.80

3/8⬙-16

2.62

2.12
1.80

1/2⬙-13

2.38
1/0 Sol. (.325 Dia.) to
500 kcmil (.813 Dia.)

Fig. “C”

2.62
2.38

2.62

2.05

3/8⬙-16

2.38
2.05
2.30
2.30

1/2⬙-13
3/8⬙-16
1/2⬙-13
3/8⬙-16

2.62

1/2⬙-13

2.30
2.62

3/8⬙-16
1/2⬙-13

L
3.58
5.62
5.88
5.62
4.12
5.62
5.88
5.62

T

2.00
.25

.31

.38

4/0 Str. (.528 Dia.) to
750 kcmil (.998 Dia.)

750 kcmil (.998 Dia.) to
1000 kcmil (1.152 Dia.)

—

1000 kcmil (1.152 Dia.)
to 1500 kcmil
(1.412 Dia.)

2.88

6.88

2.62

6.12
1000 kcmil (1.152 Dia.)
to 1500 kcmil
(1.412 Dia.)

3.06

2.88

1/2⬙-13

7.12
6.31
7.31

500 kcmil (.813 Dia.) to 500 kcmil (.813 Dia.) to 1500 kcmil (1.412 Dia.) to
2000 kcmil (1.632 Dia.) 1500 kcmil (1.412 Dia.) 2000 kcmil (1.632 Dia.)

3.25

3.12

2.56
2.20
2.56
2.44
2.81
2.44

.31
4/0 Str. (.528 Dia.) to
1000 kcmil (1.152 Dia.)

2.44
2.00
2.20

.25
5.88

W

6.50
7.50

2.44
2.81

.44
.38
.31
.50
.41
.38
.69
.50
.44

2.88
3.19

3.38

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

L-17

BURNDY® Products

Substation — Bolted

TYPE N2AH
TERMINAL
FOR TWO COPPER
CABLES TO FLAT
U

W
High copper alloy, reversible cap terminal for
joining a wide range of two copper cables to
equipment pads. Tongue is side formed to
provide adequate clearance and terminal is
designed for one-wrench installation.

B
T

H

J

Catalog
Number

L-18

Fig.
No.

N2AH34-34N

1

N2AH40-34N

1

N2AH44-34N

1

N2AH44-44N

2

N2AH46-44N

2

Complete
Cable Range
1/0 Str. (.325) to
500 kcmil (.813)
2/0 Str. (.420) to
800 kcmil (1.031)
4/0 Str. (.529) to
1000 kcmil (1.152)
4/0 Str. (.529) to
1000 kcmil (1.152)
1000 kcmil (1.152) to
1500 kcmil (1.411)

Copper Cable Range
Small
Groove

Large
Groove

1/0 Sol. (.325) to
4/0 Str. (.529)
2/0 Str. (.420) to
500 kcmil (.813)
4/0 Str. (.529) to
750 kcmil (.998)
4/0 Sol. (.529) to
750 kcmil (.998)

250 kcmil (.575) to
500 kcmil (.813)
500 kcmil (.813) to
800 kcmil (1.031)
750 kcmil (.998) to
1000 kcmil (1.152)
750 kcmil (.998) to
1000 kcmil (1.152)

—

—

Fig. 1

L

B

H

U

2.63
[67]
2.63
[67]
2.88
[73]
2.88
[73]
3.07
[78]

2.30
[58]
2.62
[67]
2.62
[67]
2.25
[57]
2.50
[64]

2.88

Dimensions Inches/[mm]
J Dia.
L

2.92
3.12
3.12
3.36

1/2 - 13

6.13
[156]
5.88
[149]
6.38
[175]
7.32
[186]
7.46
[189]

T

W

.31
[8]
.31
[8]
.50
[13]
.50
[13]
.75
[19]

3.88
[99]
5.70
[145]
4.69
[119]
6.12
[155]
6.50
[165]

Fig. 2

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE VA, VVA
VARILUG
FOR COPPER CABLE
High copper alloy terminal for joining a wide
range of cable to equipment pads or bar.
Particularly suitable for use on extra flexible
cable. One-wrench installation. Type VVA,
twin elements secure joint against vibration
and flexing. Particularly recommended for
use on extra flexible cables. One-wrench
installation.

Type VA
Type VVA

L-19

Catalog Number*
Type VA
Type VVA
VA2C
VA25
VA28
VA28-2N
VA30
VA30-2N
VA34
VA34-2N
—
VA40
VA40-2N
VA40-4N

—
—
VVA28
VVA28-2N
VVA30
VVA30-2N
VVA34
VVA34-2N
VVA34-4N
VVA40
VVA40-2N
VVA40-4N

Conductor
8 Sol. - 2 Str.
6 Sol. - 1/0 Str.
1/0 Str. - 4/0 Str.
1/0 Str. - 300
300 - 500

500 - 800

No. of
Holes
in Pad
1
1
2 NEMA
1
2 NEMA
1
2 NEMA
4 NEMA
1
2 NEMA
4 NEMA

C

D

E&F

H

13/16
7/8

1-1/4
1-3/8
1-1/2
3-1/2
1-5/8
3-5/8
2
3-5/8
3-1/16
2-3/8
3-5/8
2-5/8

—
—
—
1-3/4
—
1-3/4
—
1-3/4
1-3/4
—
1-3/4
1-3/4

1-1/2
1-7/8

1-1/16
1-1/8
1-3/8
3
1-5/8
3

1-7/8
2-1/4
2-5/8
2-9/16
2-1/8

K
7/16
7/16
9/16
7/16
9/16
9/16
9/16
9/16
11/16
9/16
9/16

L

LL

N

2-3/4
2-1/8
2-5/8
5
3-1/4
5-1/4
3-7/8
5-3/8
5-3/8
4-1/2
5-7/8
5-7/8

4-1/8
4-3/8
4-1/8
6-1/4
4-5/8
6-5/8
5-3/8
6-1/8
6-7/8
6-3/8
7-3/4
7-3/4

3/8
1/2
1/2
5/8
5/8
5/8
7/8
5/8
5/8
1
5/8
5/8

T
1/4

5/16

3/8

* “N” indicates NEMA standard stud holes.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

TYPE UH
BUS SUPPORT
FOR COPPER TUBE
High copper alloy bus support for mounting
tube on a post or pedestal type insulator.
Single bolt allows rotation to any angle.
Rotate cap 180° for slip or rigid fit. Onewrench installation. Supplied with hardware
for mounting to cap of insulator. Specify base
mounting hardware, if required, by adding
suffix “B” to Catalog No.

Catalog
Number

Copper
Conductor
IPS “A”

UH14-3
UH15-3
UH15-5
UH16-3
UH16-5
UH17-3
UH17-5
UH18-3
UH18-5
UH19-3
UH19-5
UH20-3
UH20-5
UH22-5

Bolt
Circle

3/4

3
3
5
3
5
3
5
3
5
3
5
3
5
5

1
1-1/4
1-1/2
2
2-1/2
3
4

B

G

H

2-1/2

2
2

2-3/8

2-7/8
3
3-1/4
3-1/2
3-5/8

2-1/2

3-7/8

2-1/4
2-11/16

J
3/8

1/2
3

3-1/4

2-3/4

4-3/8

3-1/8

5

3-5/8

5-7/8

4-1/2

7-1/4

5/8

K

W

9/16
9/16
11/16
9/16
11/16
9/16
11/16
9/16
11/16
9/16
11/16
9/16
11/16
11/16

2-5/8
2-7/8
3-1/2
4
4-5/8
5-1/4
6-1/4
7-1/2

L-20

TYPE UHR
BUS SUPPORT
FOR COPPER CABLE
OR TUBE
High copper alloy bus support clamp for
mounting a wide range of cable or tube on
post or pedestal type insulators. Single bolt
allows rotation to any angle. Supplied with
hardware for mounting to cap of insulator.
Specify base mounting hardware, if required,
by adding suffix “-B” to Catalog No.

Catalog
Number
UHR13-3
UHR13-5
UHR15-3
UHR15-5
UHR17-3
UHR17-5

Copper Conductor “A”
Cable
Tube
6 Str. - 500

1/8 - 1/2

4/0 Str. - 1250

1/4 - 1

750 - 2500

3/4 - 1-1/2

Bolt
Circle
3
5
3
5
3
5

B
3-5/8
3-3/4
2-7/8

G*

H

1-3/4
2-1/8
2
2-1/4

3
3-3/8
3-1/2
3-3/4

J
3/8

2-1/2

4-1/4

1/2

K
9/16
11/16
9/16
11/16
9/16
11/16

W
2-1/4
2-3/4
4

* With maximum conductor in place.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPES LH, LHR
BUS SUPPORT
FOR COPPER CABLE
OR TUBE
High copper alloy, light duty bus support for
mounting a wide range of cable or tube on
post or pedestal type insulators. One-wrench
installation. Supplied with hardware for
mounting to cap of insulator. Specify base
mounting hardware, if required, by adding
suffix “-B” to Catalog No.

Copper Cable Range
Complete Range

➄ Bolt ➅
Circle

Tubing
Schedule 40/80

Catalog
Number

6 Sol. - 4/0 Str.

—

3⬙

LH28-3

➂ #8 - 250 kcmil

1/8 - 1/4

3⬙

LHR29-3

2/0 Str. - 500 kcmil

1/4 - 1/2

3⬙

LH34-3

NOTES:
1 Material:
Connector: Cast copper alloy
Clamping Hardware: Silicon bronze
Mounting Hardware: Galvanized steel
2

Dimensions in brackets [ ] are in millimeters.

➂

Complete range may be accommodated by reversing
the cap.

➃

Dimension with maximum conductor in place.

➄

➅

B

G➃

1.69
[43]
1.00
[25]
1.38
[35]

1.25
[32]
1.23
[31]
1.38
[35]

Dimensions Inches/[mm]
H➃
J
K
2.62
[66.5]
2.03
[52]
2.50
[63.5]

3/8 - 16

.56
[14]
.56
[14]
.56
[14]

W
4.25
[108]
4.25
[108]
4.25
[108]

Cap mounting hardware is supplied as standard. 3.00
Dia. bolt circle furnished with four 1/2 -13 ⫻ 1.00 long
galvanized steel hex head bolts and split lockwashers.
5.00 Dia. bolt circle furnished as above except bolts are
.625 ⫻ 1.75.
If base mounting is desired, add “-B” to the Catalog
Number and the following hardware will be supplied:
3.00 Dia. bolt circle furnished 1/2 -13 ⫻ 1-1/2 long galvanized steel hex head bolt, hex nuts, and 5.00 Dia. bolt
circle furnished as above except bolts are .625 ⫻ 1.75.

L-21

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

TYPE NDR
STUD CONNECTOR
FOR COPPER CABLE,
TUBE, FLAT BAR
High copper alloy reversible and rotatable
cap stud connector joins cable, tube and flat
bar in-line or at right angles to equipment
studs. Accommodates a wide range of
cables or tubes. One-wrench installation.

Fig. 1

Fig. 2

L-22

Catalog
Number

Stud
A

NDR6328T13
NDR6428T16
NDR6434T16
NDR6444T16
NDR6528T14
NDR6534T14
NDR6544T14
NDR65528T12
NDR65534T12
NDR65544T12
NDR6644T12
NDR6728T12
NDR6734T12
NDR6744T12
NDR6748T12
NDR6844T12
NDR6848T12

1/2-13

Complete Range AA
Fig.
Cable
Tube I.P.S. No.

6 Sol. - 4/0 Str.
6 Sol. - 4/0 Str.
3/4-16
6 Sol. - 500
2 Sol. - 1000
6 Sol. - 4/0 Str.
1-14
6 Sol. - 500
2 Sol. - 1000
6 Sol. - 4/0 Str.
1-1/8-12
6 Sol. - 500
2 Sol. - 1000
1-1/4-12 2 Sol. - 1000
6 Sol. - 4/0 Str.
6 Sol. - 500
1-1/2-12
2 Sol. - 1000
4/0 Str. - 2000
2 Sol. - 1000
2-12
4/0 Str. - 2000

—
—
3/8 - 1/2
3/8 - 3/4
—
3/8 - 1/2
3/8 - 3/4
—
3/8 - 1/2
3/8 - 3/4
3/8 - 3/4
—
3/8 - 1/2
3/8 - 3/4
3/8-1-1/4
3/8 - 3/4
3/8-1-1/4

1
2
1
2
1
2
1

2

X
Groove

XX
Groove

6 Sol. - 1 Str.
6 Sol. - 1 Str.
250 - 350
550 - 700
6 Sol. - 1 Str.
250 - 350
550 - 700
6 Sol. - 1 Str.
250 - 350
550 - 700
550 - 700
6 Sol. - 1 Str.
250 - 350
550 - 700
1250 - 1600
550 - 700
1250 - 1600

2/0 Sol. - 4/0 Str.
2/0 Sol. - 4/0 Str.
400 - 500
750 - 1000
2/0 Sol. - 4/0 Str.
400 - 500
750 - 1000
2/0 Sol. - 4/0 Str.
400 - 500
750 - 1000
750 - 1000
2/0 Sol. - 4/0 Str.
400 - 500
750 - 1000
1700 - 2000
750 - 1000
1700 - 2000

Z
Groove

ZZ
Groove

E

H

1-1/16

1-3/4

6 Sol. - 2 Str. 1/0 Sol. - 4/0 Str. 1-7/16
2 Sol. - 250
300 - 500
1-7/8
1-1/16
6 Sol. - 2 Str. 1/0 Sol. - 4/0 Str. 1-7/16
2 Sol. - 250
300 - 500
1-7/8
1-1/16
6 Sol. - 2 Str. 1/0 Sol. - 4/0 Str. 1-7/16
2 Sol. - 250
300 - 500
1-7/8
2 Sol. - 250
300 - 500
1-7/8
1-1/16
6 Sol. - 2 Str. 1/0 Sol. - 4/0 Str. 1-7/16
2 Sol. - 250
300 - 500
1-7/8
4/0 Str. - 600
650 - 1200
2-3/8
2 Sol. - 250
300 - 500
1-7/8
4/0 Str. - 600
650 - 1200
2-3/8

2-1/4
2-7/8
1-3/4
2-1/4
2-7/8
1-3/4
2-1/4
2-7/8
2-7/8
2-1/4
2-3/8
2-7/8
3-1/4
2-7/8

J

JJ
3/8
1/2

3/8

3/8
1/2
3/8
1/2
3/8

1/2
1/2

L
3-5/8
4-1/8
4-5/8
4-1/8
4
4-3/4
4-1/8
4
4-5/8
4-5/8
4-3/4
5
5-1/8
5-3/4
6-1/8
6-5/8

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE FD
STUD CONNECTOR
FOR STUD TO FLAT BAR
High copper alloy stud connector allows
bolting cable and tubing terminals to equipment studs. Hex head captured bolts provide
one-wrench installation. One pad contact
surface is on centerline of stud. Pad is finished on both sides. All pads are four hole
NEMA drilled.

Catalog
Number
FD64C5T16
FD65C6T14
FD655C6
FD655D6
FD66C6
FD66D6
FD67C6
FD67D8
FD675C8
FD675D8
FD68C8
FD68D8
FD68D12
FD685C8
FD685D8
FD685D12
FD69C8
FD69D8
FD69D12
FD70D12
FD70D16

Stud
A
3/4⬙ -16
1⬙-14
1-1/8⬙-12
1-1/4⬙-12
1-1/2⬙-12
1-3/4⬙-12
2⬙-12

2-1/4⬙-12

2-1/2⬙-12
3⬙-12

Nominal
Ampere
Rating ➀
1000
1075
1075
1300
1075
1300
1075
1450
1220
1450
1220
1450
2100
1220
1450
2100
1220
1450
2100
2100
3000

B

1.75

2.18

2.50

2.88

C

D

3.00
3.00
3.00
4.00
3.00
4.00
3.00
4.00
3.00
4.00
3.00
4.00
4.00
3.00
4.00
4.00
3.00
4.00
4.00
4.00
4.00

3.00
3.00
3.00
4.00
3.00
4.00
3.00
4.00
3.00
4.00
3.00
4.00
4.00
3.00
4.00
4.00
3.00
4.00
4.00
4.00
4.00

J

3/8⬙-16

1/2⬙-13

5/8⬙-11

L

N

T

5.72
5.72
5.80
6.86
5.78
6.84
6.23
7.30
6.32
7.39
6.35
7.42
7.42
6.71
7.77
7.77
6.77
8.03
8.03
8.26
8.24

.62
.62
.62
1.12
.62
1.12
.62
1.12
.62
1.12
.62
1.12
1.12
.62
1.12
1.12
.62
1.12
1.12
1.12
1.12

.31
.38
.38
.38
.38
.38
.38
.50
.50
.50
.50
.50
.75
.50
.50
.75
.50
.50
.75
.75
1.00

NOTES:
➀ Indoor Rating
2. Contact factory for other variations in drilling, plating, etc.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

L-23

BURNDY® Products

Substation — Bolted

TYPE QGFL
BARTAP™
FOR COPPER CABLE TO FLAT
High copper alloy BARTAP™ for joining a range
of cable to bar or pad. One-wrench installation.

Catalog
Number

Conductor

QGFL1CB1
QGFL1CB1T6
QGFL26B1
QGFL26B1T6
QGFL26B2*
QGFL26B2T6*
QGFL29B1*
QGFL29B1T6*
QGFL31B1*
QGFL31B1T6*
QGFL34B1
QGFL34B1T6
QGFL39B1
QGFL39B1T6
QGFL44B1
QGFL44B1T6
QGFL46B1
QGFL46B1T6
QGFL48B1

B

10 Sol. - 1 Str.

1-1/8
1-1/4

8 Sol. - 2/0 Str.

1-1/2
6 Str. - 250

1-5/8

2 Sol. - 350

1-3/4

1/0 Sol. - 500

2

350 - 750
750 - 1000
2-1/4
1000 - 1500
1500 - 2000

H

J

1-7/8
2-3/8
2-1/8
2-5/8
1-1/2
2-7/8
2-5/8
3-1/8
2-7/8
3-1/4
3-1/8
3-5/8
3-1/4
3-5/8
3-3/8
4-1/8
4
4-1/2
4-3/4

3/8

1/2

T
(Max.)
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4
3/4
1/4

W
1

1-1/8

1-3/8
1-5/8
1-3/4
1-3/4
2-1/8
2-1/2
3

* Can be installed side by side or in-line on NEMA drilled bar.

L-24

TYPE FCB
TRANSFORMER
TAP ADAPTER
FOR COPPER AND ALUMINUM
Cast in one piece from copper alloy.
Transformer tap adapter designed to accommodate from 1 to 6 NEMA drilled copper or
aluminum terminal taps from a single
secondary transformer outlet. Tin-plated.
Order mounting hardware and tap terminals
separately.

Fig.
No.

Catalog
Number

A
Dia.

H
REF

L

P

1
2
1
2
1
3
4

FCB63-4N
FCB63-6N
FCB64-4N
FCB64-6N
FCB65-4N
FCB63-2NP300
FCB64-44NP50

.50
.50
.75
.75
1.00
.50
.75

5.25
5.25
5.75
5.75
7.00
5.00
9.00

3.75
5.50
4.00
5.75
4.25
3.50
5.00

2.25
2.25
2.75
2.75
4.00
3.00
5.00

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE E-C-G
TRANSFORMER
TAP ADAPTER
FOR COPPER CABLE
Multi-tap, range-taking cast copper alloy
connector designed to take 2, 3, or 4 conductors from a single secondary transformer
outlet.

Catalog
Number

Number of
Conductors

E2C34G1
E3C34G1
E4C34G1

2
3
4

Conductor Size
1/0 Sol. to 500

A
Dia.
.78

D

H

3-3/4

3-7/8

J
1/2-13

L

W

6-1/4

3-1/2
5-1/4
6-7/8

TYPE FN

L-25

CONTACT NUT
FLAT TO STUD
High copper alloy contact nut for joining bar
or terminal pads to studs. Designed to carry
full current load from flat to stud.

Catalog Number
Type FN

Stud Dia. and
Threads per Inch

CF
(Cross Flats)

FN62T16
FN63T13
FN64T16
FN655T12
FN66T14
FN67T12

3/8 - 16
1/2 - 13
3/4 - 16
1-1/8 - 12
1-1/4 - 14
1-1/2 - 12

3/4
1
1-1/4
1-3/4
2
2-3/8

H

T

W

3/8
15/32
3/4
1

5/16
3/8
9/16
3/4

1-1/8

7/8

7/8
1-1/4
1-1/2
2-1/8
2-3/8
2-3/4

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

ALUMINUM INTRODUCTION
CONNECTORS FOR
ALUMINUM CONDUCTORS
Bolted aluminum connectors are cast of aluminum alloy and assembled with aluminum
alloy bolts, nuts and galvanized steel
washers. The hex head bolts are captured for
one-wrench installation. The connectors
accommodate aluminum or copper conductor. The “mass anode” design pioneered by
BURNDY® minimizes the effect of galvanic
corrosion on aluminum (anode+) connectors
when used with copper (cathode –) conductor (Reference Fig. 1).
Joint deterioration caused by relaxation or
“cold flow” of the aluminum is eliminated by
the massive design. Generous contact areas
distribute clamping forces evenly over the
conductor, eliminating points of high stress
that cause “cold flow.” These contact areas
are factory treated to remove surface oxides
and coated with an oxide inhibitor to prevent
their reformation. Large radiating surfaces
allow the connectors to run cooler than the
copper conductor compensating for the fact
that aluminum has a higher coefficient of
thermal expansion. Connector and conductor expand and contract together during load
cycles, eliminating stresses on the aluminum
body that can cause relaxation of the joint.

CONNECTOR SELECTION

CONDUCTOR PREPARATION

Generally, copper connectors are recommended for copper conductor and aluminum
connectors for aluminum conductor. Where
aluminum connectors are recommended for
use on both aluminum and copper conductors, the copper must be positioned parallel
to or below the aluminum to prevent contamination of the aluminum by copper salts
washed down by rain.

To obtain optimum performance from any
connector, the conductor surface must be
thoroughly cleaned before installation. The
surface oxides that form on all conductors
act as insulation. Failure to remove them
can result in high resistance joint and, ultimately, failure.

Except where indicated, all rigid connectors
accept standard or extra heavy I.P.S. and all
flexible connectors standard I.P.S. If extra
heavy I.P.S. is to be used with a flexible joint,
it must be spelled out at the time of ordering
so that the proper cross sectional area of the
flexible element may be supplied for the
increased conductor rating.

Conductor contact surfaces should be
scratch brushed until bright and shiny.
Aluminum conductor (new or old) should be
coated with BURNDY® PENETROX™ after
scratch brushing. PENETROX™ is a joint
compound that aids in the establishment of
low resistance joints and prevents aluminum
oxides from reforming.

L-26

Many aluminum ions
removed by current flow

Few aluminum ions
removed by current flow

Aluminum Anode
Copper Cathode

Copper Cathode

Aluminum Anode

Fig. 1

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE NNT-A
T-CONNECTOR
FOR ALUMINUM AND COPPER
TUBE TO TUBE
Aluminum alloy T-Connector for tubing run
and tap. Properly proportioned to permit use
on copper-aluminum conductor combinations. Captured hex head bolts permit onewrench installation. PENETROX™ joint
compound recommended on contact surfaces.

Catalog
Number

Run

Conductor
Tap

B

H

J

L

NNT15A15A
NNT16A16A
NNT17A17A
NNT18A18A
NNT19A19A
NNT20A20A

1
1-1/4
1-1/2
2
2-1/2
3

1
1-1/4
1-1/2
2
2-1/2
3

3-1/2
3-3/4
4
4-1/4
4-/12
5

3-3/8
3-3/8
3-7/8
4-1/2
5
5

1/2
1/2
1/2
5/8
5/8
5/8

6-7/8
7-/12
7-7/8
9
9
11

TYPE NNTR-A
T-CONNECTOR
L-27

FOR ALUMINUM & COPPER
TUBE TO CABLE
Aluminum alloy T-Connector for tube run,
range of cable tap. Properly proportioned to
permit use on copper-aluminum combinations. One-wrench installation. PENETROX™
joint compound recommended on contact
surfaces.

Catalog
Number

Run

Conductor
Tap
Alum. or Cu.

NNTR14A29A
NNTR14A36A
NNTR15A36A
NNTR15A42A
NNTR16A29A
NNTR16A32A
NNTR16A42A
NNTR17A29A
NNTR18A29A
NNTR19A42A
NNTR20A32A

3/4
3/4
1
1
1-1/4
1-1/4
1-1/4
1-1/2
2
2-1/2
3

1/0 Str. - 250
350 - 600
350 - 600
600 - 900
1/0 Str. - 250
250 - 400
600 - 900
1/0 Str. - 250
1/0 Str. - 250
600 - 900
250 - 400

ACSR

H

1/0 (6-1) - 4/0 (6-1)
336.4 (18-1) - 477 (30-7)
336.4 (18-1) - 477 (30-7)
477 (30-7) - 795 (54-7)
1/0 (6-1) - 4/0 (6-1)
4/0 (6-1) - 397.5 (18-1)
477 (30-7) - 795 (54-7)
1/0 (6-1) - 4/0 (6-1)
1/0 (6-1) - 4/0 (6-1)
477 (30-7) - 795 (54-7)
4/0 (6-1) - 397.5 (18-1)

3-1/8
3-1/8
3-3/8
3-3/8
3-3-/8
3-3/8
3-7/8
3-7/8
4-1/2
4-5/8
5

J

1/2

JJ

L

1/2

5-7/8
6-3/8
6-5/8
6-7/8
6-1/2
6-3/4
7-1/4
6-3/4
7-5/8
8-7/8
9

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

TYPE NNTR-A
T-CONNECTOR
FOR ALUMINUM AND COPPER
CABLE TO CABLE
Aluminum alloy T-Connector for a range of
copper, aluminum and ACSR cable on run
and tap. Properly proportioned to permit use
on copper-aluminum conductor combinations. One-wrench installation. PENETROX™ joint compound recommended on
contact surfaces.

Fig. 1

Fig. 2

Conductor
Run
Catalog
Number
NNTR29A29A
NNTR32A25A
NNTR32A32A
NNTR36A29A
NNTR36A36A
NNTR42A32A
NNTR42A36A
NNTR42A42A
NNTR45A45A
NNTR46A42A
NNTR46A46A
NNTR48A48A
L-28

Alum. or
Copper
1/0 Str. - 250
250 - 400
250 - 400
350 - 600
350 - 600
600 - 900
600 - 900
600 - 900
900 - 1250
1250 - 1600
1250 - 1600
1500 - 2000

Tap
ACSR

Alum. or
Copper

ACSR

Fig.
No.

B

H

1/0 (6-1) - 4/0 (6-1)
4/0 (6-1) - 397.5 (18.1)
4/0 (6-1) - 397.5 (18-1)
336.4 (18-1) - 477 (30-7)
336.4 (18-1) - 477 (30-7)
477 (30-7) - 795 (54-7)
477 (30-7) - 795 (54-7)
477 (30-7) - 795 (54-7)
715.5 (30-19) - 1113 (54-19)
1113 (54-19) - 1431 (45-7)
1113 (54-19) - 1431 (45-7)
1272 (54-19) - 1780 (84-19)

1/0 Str. - 250
4 Str. - 1/0 Str.
250 - 400
1/0 Str. - 250
350 - 600
250 - 400
350 - 600
600 - 900
900 - 1250
600 - 900
1250 - 1600
1500 - 2000

1/0 (6-1) - 4/0 (6-1)
4 (6-1) - 1/0 (6-1)
4/0 (6-1) - 397.5 (18-1)
1/0 (6-1) - 4/0 (6-1)
336.4 (18-1) - 477 (30-7)
4/0 (6-1) - 397.5 (18-1)
336.4 (18-1) - 477 (30-7)
477 (30-7) - 795 (54-7)
715.5 (30-19) - 1113 (54-19)
477 (30-7) - 795 (54-7)
1113 (54-19) - 1431 (45-7)
1272 (54-19) - 1780 (84-19)

2
1
2
2
2
2
2
2
2
2
2
2

2-3/4
1-7/8
3
3-1/4
3-1/4
3-1/2
3-1/2
3-1/2
3-3/4
3-3/4
4-3/8
4-3/8

2-5/8
2-5/8
2-5/8
2-5/8
2-5/8
3-1/8
3-1/8
3-1/8
3-1/4
3-1/2
3-3/4
3-7/8

J

1/2

5/8
5/8

L
5-5/8
4-7/8
6
5-7/8
6-3/8
6-3/8
6-5/8
6-7/8
7-3/8
7-1/4
8-3/8
8-5/8

TYPE NS-A
COUPLER
FOR ALUMINUM AND COPPER
TUBE TO TUBE
Aluminum alloy coupler for joining equal
sizes of tube end to end. Properly proportioned to permit use on aluminum-copper
conductor combinations. One-wrench installation. PENETROX™ joint compound recommended on contact surfaces.

Catalog
Number
NS14A14A
NS15A15A
NS17A17A
NS18A18A
NS19A19A
NS20A20A
NS21A21A
NS22A22A
NS24A24A

Conductor
I.P.S.
3/4
1
1-1/2
2
2-1/2
3
3-1/2
4
5

Fig.
No.

Fig. 1

J
1/2

1
5/8
2

L
6-3/4
7-1/4
8-1/4
8-3/4
9-1/4
10-1/4
11-1/4
12-1/4
14-1/4

Fig. 2

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE NA-A
TERMINAL
FOR ALUMINUM AND COPPER
TUBE TO FLAT
Aluminum alloy terminal for joining copper or
aluminum tube to copper or aluminum pad.
Properly proportioned to minimize conductor
corrosion due to galvanic action. Drilling in
pad conforms to NEMA standards. Onewrench installation. PENETROX™ joint compound recommended on contact surfaces.

Fig. 1

Fig. 2
Catalog
Number

Conductor

Fig.
No.

B

C

G

H

J

L

T

W

NA15A-2N
NA15A-4N
NA16A-4N
NA17A-2N
NA17A-4N
NA18A-2N
NA18A-4N
NA19A-4N
NA20A-4N

1
1
1-1/4
1-1/2
1-1/2
2
2
2-1/2
3

2
1
1
2
1
2
1
1
1

3-1/2
3-1/2
3-3/4
4
4
4-1/4
4-1/4
4-1/2
5

1-7/8
3
3
2-1/2
3
2-3/4
3-1/8
3-3/4
4-3/8

1.50
1.50
1.60
1.76
1.76
2.05
2.05
2.19
2.43

3-3/8
3-3/8
3-3/8
3-7/8
3-7/8
4-1/2
4-1/2
5
5-1/2

1/2
1/2
1/2
1/2
1/2
5/8
5/8
5/8
5/8

6-3/4
6-3/4
7
7-1/2
7-1/2
7-1/2
7-1/2
7-3/4
8-3/8

3/8
3/8
1/2
1/2
1/2
1/2
1/2
3/4
3/4

3-1/16
3-1/16
3-7/16
3-11/16
3-11/16
4-1/2
4-1/2
5
5-5/8
L-29

TYPE XA-A
EXPANSION TERMINAL
FOR ALUMINUM AND COPPER
TUBE TO FLAT
Aluminum alloy expansion connector for joining tube to copper or aluminum bar or equipment pads. Flexible aluminum straps allow
longitudinal or lateral movement and carries
full current load of the joint. PENETROX™
joint compound recommended on contact
surfaces. Pad contact surface is on centerline of conductor.

Catalog Number*
Standard I.P.S.
(Schedule 40) With Guide

Conductor

C

XA15A-4N
XA16A-4N
XA18A-4N
XA19A-4N
XA20A-4N
XA21A-4N
XA22A-4N
XA24A-4N

1
1-1/4
2
2-1/2
3
3-1/2
4
5

3
3
3
3-3/4
4-3/8
4-3/4
5-1/4
6-1/2

J
1/2

5/8

L

T

12-3/4
13-5/8
15-1/2
17
18-5/8
20
21
24-1/8

3/8
1/2
1/2
5/8
5/8
7/8
7/8
7/8

* Conforms to 4-hole NEMA mounting standards.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

TYPE NBC-A
BARTAP™
Aluminum alloy bolted type terminal for joining aluminum tube to copper or aluminum
pads. Drilling in pad conforms to NEMA
Standards. PENETROX™ joint compound
recommended on contact surfaces.

Fig. 1
Conductor
Aluminum
IPS/EHPS
A
1⬙
1-1/4⬙

L-30
1-1/2⬙

2⬙

2-1/2⬙

1.32
[33]
1.66
[42]

1.90
[48]

2.38
[42]

2.88
[73]

3⬙

3.50
[76]

4⬙

4.50
[114]

5⬙

Fig. 3

Fig. 2

5.56
[141]

NOTES:
1. Materials:
Connector: Cast Aluminum Alloy
Hardware: Aluminum Alloy

Catalog
Number

Fig.
No.

NBC15A-2N
NBC15A-34N

1
2

NBC16A-2N

1

NBC17A-2N

1

NBC17A-34N

2

NBC17A-44N

3

NBC18A-2N

1

NBC18A-34N

2

NBC18A-44N

3

NBC19A-34N

2

NBC19A-44N

3

NBC20A-44N

3

NBC22A-34N

2

NBC22A-44N

3

NBC24A-34N

2

B

H

3.50
[89]
3.75
[95]
4.00
[102]
4.00
[102]
4.00
[102]
4.25
[108]
4.25
[108]
4.25
[108]
4.50
[114]
4.50
[114]
5.00
[127]
6.00
[152]
6.00
[152]
7.00
[178]

3.00
[76]
3.25
[76]
3.50
[89]
3.50
[89]
3.50
[89]
4.00
[76]
4.00
[76]
4.00
[76]
4.50
[114]
4.50
[114]
4.50
[114]
5.50
[140]
5.50
[140]
6.00
[152]

Dimensions Inches [mm]
J
L
1/2 - 13
1/2 - 13
1/2 - 13
1/2 - 13
1/2 - 13
5/8 - 11
5/8 - 11
5/8 - 11
5/8 - 11
5/8 - 11
5/8 - 11
5/8 - 11
5/8 - 11
5/8 - 11

2. Scratch brush connector contact, surface dry then apply an
oxide inhibitor, “PENETROX™ A”. “PENETROX™ A” can be
purchased from BURNDY® Corporation in can or plastic
squeeze bottles.

6.81
[173]
7.15
[182]
7.39
[188]
7.39
[188]
8.39
[213]
8.25
[210]
8.25
[210]
9.25
[135]
8.75
[222]
9.75
[248]
10.37
[263]
10.37
[263]
11.37
[289]
12.45
[316]

T

Y

.38
[10]
.38
[10]
.38
[10]
.38
[10]
.38
[10]
.38
[10]
.38
[10]
.38
[10]
.50
[13]
.50
[13]
.50
[13]
.62
[16]
.62
[16]
.62
[16]

5.28
[134]
5.45
[138]
5.57
[141]
5.57
[141]
6.57
[167]
6.00
[152]
6.00
[152]
7.00
[178]
6.25
[159]
7.25
[184]
7.56
[192]
7.06
[179]
8.06
[205]
8.60
[218]

3. Recommended Tightening Torque:
1/2-13 300 Inch Pounds
5/8-11 480 Inch Pounds
4. All dimensions in brackets [ ] are in millimeters.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE NAR-A
TERMINAL
FOR ALUMINUM AND COPPER
CABLE TO FLAT
Aluminum alloy terminal for joining a wide
range of copper or aluminum cable to copper
or aluminum pad. Properly proportioned to
minimize conductor corrosion due to galvanic action. Drilling in pad conforms to NEMA
standards. One-wrench installation. PENETROX™ A joint compound recommended on
contact surfaces.

Fig. 1
Catalog
Number
NAR25A-2N
NAR29A-2N*
NAR29A-4N*
NAR32A-2N
NAR32A-4N
NAR36A-2N
NAR36A-4N*
NAR42A-2N**
NAR42A-4N*
NAR45A-2N
NAR45A-4N
NAR46A-2N
NAR46A-4N*
NAR48A-2N
NAR48A-4N

Conductor
Alum. or Copper
ACSR
4 Str. - 1/0 Str.

No. of Holes
in Pad

4 (6-1) - 1/0 (6-1)

1/0 Str. - 250

1.0 (6-1) - 4/0 (6-1)

250 - 400

4/0 (6-1) - 397.5 (18-1)

2 NEMA

350 - 600

336.4 (18-1) - 477 (30-7)

600 - 900

477 (30-7) - 795 (54-7)

900 - 1250

715 (30-19) - 1113 (54-19)

1250 - 1600

1113 (54-19) - 1431 (54-7)

1500 - 2000

Fig. 2

1272 (54-19) - 1780 (84-19)

4 NEMA
2 NEMA
4 NEMA
2 NEMA
4 NEMA
2 NEMA
4 NEMA
2 NEMA
4 NEMA
2 NEMA
4 NEMA
2 NEMA
4 NEMA

Fig. 2A

Fig.
No.

C

H

1
2
2A
2
2A
2
2A
2
2A
2
2A
2
2A
2
2A

1-1/4
1-5/8
3
1-5/8
3
1-3/4
3
2
3
2-5/8
3
2-3/4
3
2-3/4
3

2-3/8
2-7/8
2-3/4

J

L

T
L-31

5-1/4
6-1/8

5/16

6-3/8
2-7/8

1/2

3/8
6-5/8
6-7/8

3-3/8

1/2
7-1/8

3-3/4

7-3/4

5/8

7-7/8

3/4

5/8
4

* Available with 90 degree pad as shown
(example: NAR36A-4N90).
** Available with 45 degree pad as shown
(example: NAR42A-2N45).

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

BURNDY® Products

Substation — Bolted

TYPE UHG-A
BUS SUPPORT
FOR ALUMINUM AND
COPPER TUBE
Aluminum alloy bus support for mounting
tube on post or pedestal insulators. Properly
proportioned to minimize conductor corrosion due to galvanic action. Rotate caps 180°
for slip or rigid fit. One-wrench installation.
Supplied with hardware for mounting to
cap of insulator. Specify base mounting

Catalog
Number

L-32

Bolt
Circle

Conductor

UHG14A-3
UHG15A-3
UHG15A-5
UHG17A-3
UHG17A-5
UHG18A-3
UHG18A-5
UHG19A-3
UHG20A-3
UHG20A-5
UHG21A-3
UHG22A-5
UHG24A-3
UHG24A-5

hardware, if required, by adding suffix “-B”
to Catalog Number. For static clips add “CH” to Catalog Number.

3/4

3
3
5
3
5
3
5
3
3
5
3
5
3
5

1
1-1/2
2
2-1/2
3
3-1/2
4
5

G

H

2
2
2-1/4

3-1/2

2-1/2

4-1/8

3-5/8

3-1/8

5-1/4
4-5/8
5-1/4

3-5/8

6-1/8

4
4-1/2

6-3/4
7-1/2

5-1/4

8-7/8

2-3/4

J

1/2

5/8

K

L

9/16
9/16
11/16
9/16
11/16
9/16
11/16
9/16
9/16
11/16
9/16
11/16
9/16
11/16

7-1/2
7-1/2
9-7/8
7-3/4
10-1/8
7-3/4
10-1/8
7-3/4
8-1/4
10-5/8
8-1/4
10-5/8
8-3/4
11-5/8

W
3
3-1/8
3-3/4
4-1/8
4-5/8
5-5/8
6-1/4
6-5/8
7-3/4

TYPE UHKR-A
BUS SUPPORT
FOR ALUMINUM
CABLE OR TUBE
Aluminum alloy bus support for mounting a
wide range of cable or tube on post or
pedestal type insulators. Supplied with hardware for mounting to cap of insulator. Specify
base mounting hardware, if required, by
adding suffix “-B” to Catalog Number.

Conductor
Catalog
Number
UHKR11A-3
UHKR11A-5
UHKR13A-3
UHKR13A-5
UHKR14A-3
UHKR14A-5
UHKR16A-3
UHKR16A-5

Cable
Aluminum

ACSR

Tube
Sch. 40/80

4 Sol. - 4/0 Str.

6 (6-1) - 4/0 (6-1)

1/4

250 - 550

266.8 (6-7) - 477 (30-7)

3/8 - 1/2

600 - 1113

556.5 (26-7) - 1033.5 (54-7)

3/4

1000 - 2000

1113 (54-19) - 1780 (84-19)

1 - 1-1/4

Bolt
Circle
3
5
3
5
3
5
3
5

G*

H

1-1/8

2-5/8

1-3/8

2-7/8

1-3/4
1-1/2
1-31/32
1-13/16

3-5/8
3-3/8
4-1/16
3-7/8

J

1/2

1/2

K

L

9/16
11/16
9/16
11/16
9/16
11/16
9/16
11/16

7-5/8
9-1/2
7-5/8
8-7/8
7-5/8
9-1/8
7-9/16
9-1/4

* With maximum conductor in place.
Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE LB-A
END CAP
Aluminum alloy end cap for aluminum tube.
Driven into place for a secure fit. Seals out
moisture, reduces electrostatic loss and
eliminates hazards created by nesting birds.

Conductor
Aluminum
Pipe Size
1/2⬙
3/4⬙
1⬙
1-1/4⬙
1-1/2⬙
2⬙
2-1/2⬙
3⬙
3-1/2⬙
4⬙
5⬙
6⬙

A

Dimensions Inches/[mm]
C

L

.84
[21]
1.05
[27]
1.32
[34]
1.66
[42]
1.90
[48]
2.38
[60]
2.88
[73]
3.50
[89]
4.00
[102]
4.50
[114]
5.56
[141]
6.63
[168]

.38
[9.7]
.50
[13]
.50
[13]
.50
[13]
.50
[13]
.88
[22]
.88
[22]
.88
[22]
.88
[22]
.88
[22]
.88
[22]
.88
[22]

1.25
[32]
1.37
[35]
1.43
[36]
1.43
[36]
1.45
[37]
1.85
[47]
2.01
[51]
2.10
[53]
2.15
[55]
2.22
[56]
2.34
[59]
2.46
[62]

Catalog Number
Schedule 40
Schedule 80
LB13A

—

LB14A

—

LB15A

—

LB16A

—

LB17A

—

LB18A

—

LB19A

—

LB20A

—

LB21A

LB91A

LB22A

—

LB24A

—

LB86A

—

NOTES:
1. Material: Cast Aluminum Alloy.
2. Dimensions in brackets [ ] are in millimeters.

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

L-33

BURNDY® Products

Substation — Bolted

TYPE WAS-A
TERMINAL CONNECTOR
Aluminum alloy weld type terminal for joining
aluminum tube to copper or aluminum pads.
Drilling in pad conforms to NEMA standards.
PENETROX™ joint compound recommended on pad contact surfaces.

Conductor
Aluminum
Sch. 40/Sch. 80

A

3/4⬙

1.05
[27]

1⬙

1.32
[34]

1-1/4⬙

1.66
[42]

1-1/2⬙

1.90
[48]

2⬙

2.38
[60]

Catalog
Number

B

WAS14A-2N
WAS15A-2N
WAS15A-34N
WAS16A-2N
WAS17A-2N
WAS17A-34N
WAS18A-2N
WAS18A-34N
WAS19A-2N

L-34
2-1/2⬙

2.88
[73]

WAS19A-34N
WAS19A-44N
WAS20A-2N

3⬙

3.50
[89]

WAS20A-34N
WAS20A-44N

3-1/2⬙

4⬙
5⬙

4.00
[102]
4.50
[114]
5.56
[141]

NOTES:
1 Material: Cast Aluminum Alloy.
➁ WELDING TO BE DONE BY THE CUSTOMER.
For welding recommendation see drawing SD73608

WSA21A-34N
WAS21A-44N
WAS22A-44N
WAS24A-44N

2.50
[64]
2.75
[70]
2.75
[70]
3.00
[76]
3.25
[83]
3.25
[83]
3.50
[89]
3.50
[89]
3.63
[92]
3.63
[92]
3.63
[92]
3.67
[93]
3.75
[95]
3.75
[95]
4.25
[108]
4.25
[108]
4.25
[108]
4.25
[108]

3 After welding, scratch brush connector contact
surface dry then apply an oxide inhibitor
“PENETROX™ A”.
“PENETROX™ A” can be purchased from BURNDY®
Corporation in cans or plastic squeeze bottles.

Dimensions Inches/[mm]
G
L
1.50
[38]
1.19
[30]
1.19
[30]
1.38
[35]
1.50
[38]
1.50
[38]
1.75
[44]
1.75
[44]
2.00
[51]
2.00
[51]
2.00
[51]
2.38
[60]
2.38
[60]
2.38
[60]
2.62
[67]
2.62
[67]
2.88
[73]
3.62
[92]

6.50
[165]
6.75
[171]
6.75
[171]
7.00
[178]
7.25
[184]
7.25
[184]
7.50
[19]
7.50
[19]
7.87
[200]
7.87
[200]
8.87
[225]
8.25
[21]
8.25
[21]
9.25
[235]
8.50
[216]
9.50
[241]
9.50
[241]
9.50
[241]

T
.38
[9.7]
.38
[9.7]
.38
[9.7]
.38
[9.7]
.44
[11]
.38
[9.7]
.44
[11]
.38
[10]
.56
[14]
.56
[14]
.50
[13]
.69
[18]
.62
[16]
.62
[16]
.62
[16]
.62
[16]
.75
[19]
.75
[19]

4 Dimensions in brackets [ ] are in millimeters.
5 Tongue finished on ONE SIDE ONLY (bottom).
For tongue finished on both sides, add suffix letter
"Q" to Catalog Number (e.g., WAS22A-44NQ).

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175

BURNDY® Products

Substation — Bolted

TYPE WASC-A-N
CENTERFORMED
WELDMENT TERMINAL
Aluminum alloy weldment terminal. Type
WASC-A-N has one contact surface on the
center line of the tube. Holes are NEMA
spaced for terminating aluminum or copper
mating pads. PENETROX™ joint compound
recommended for use on contact surfaces.

Catalog
Number

Aluminum Conductor
Schedule 40/80
A [mm]

WASC14A2N
WASC15A2N
WASC15A34N
WASC16A2N
WASC16A34N
WASC17A34N
WASC18A34N
WASC18A44N
WASC19A2N
WASC19A34N
WASC19A44N
WASC20A2N
WASC20A34N
WASC20A44N
WASC21A2N
WASC21A34N
WASC21A44N
WASC22A2N
WASC22A34N
WASC22A44N
WASC24A34N
WASC24A44N
WASC86A44N

Fig. 3

Fig. 2

Fig. 1

3/4⬙

1.05 [27]

1⬙

1.32 [33]

1-1/4⬙

1.66 [42]

1-1/2⬙

1.90 [48]

2⬙

2.38 [60]

2-1/2⬙

2.88 [73]

3⬙

3-1/2⬙

4⬙

3.50 [89]

4.00 [102]

4.50 [114]

5⬙

5.56 [141]

6⬙

6.63 [168]

Fig.
No.
1
1
2
1
2
2
2
3
1
2
3
1
2
3
1
2
3
1
2
3
2
3
3

Dimensioins Inches/[mm]
B
L
T
2.50 [64]

6.44 [164]

.22 [6]

2.75 [70]

6.69 [170]

.38 [10]

3.00 [76]

7.00 [178]

.38 [10]

3.25 [83]

7.31 [186]
7.56 [192]
8.56 [217]

.44 [11]

3.50 [90]
3.75 [95]

7.88 [200]

.50 [13]
.56 [14]

8.88 [226]
4.00 [102]

8.13 [207]
9.13 [232]

4.25 [108]

.62 [16]

8.38 [213]
9.38 [238]

4.25 [108]
4.25 [108]
4.25 [108]

8.38 [213]
9.38 [238]
8.50 [216]
9.50 [241]
9.50 [241]

.75 [19]
.75 [19]
1.00 [25]

For tongue finished on both sides add suffix letter "Q" to
Catalog Number (e.g., WASC14A2NQ).

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
US: 1-800-346-4175

www.burndy.com

Canada: 1-800-387-6487

L-35

BURNDY® Products

Substation — Bolted

TYPE WG-A
WELDMENT GROUND STUD

B

.75 DIA.
[19]

Range-taking weldment stud for grounding
Aluminum tube.
1.50 DIA.
[38]

W

6.00
[152]
“A” DIA.
Y

Catalog Number

Aluminum IPS

WG19A

1⬙ - 2-1/2⬙

WG86A

3⬙ - 6⬙

A
1.315 - 2.88
[33] - [73]
3.50 - 6.62
[89] - [168]

Dimensioins Inches/[mm]
B
W
3.00
[76]
2.00
[51]

1.32
[34]
3.06
[78]

Y
8.19
[208]
10.31
[262]

Dimensions in brackets [ ] are in millimeters

L-36

Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY® Products.
Canada: 1-800-387-6487

www.burndy.com

US: 1-800-346-4175



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Page Mode                       : UseOutlines
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23
Modify Date                     : 2008:05:28 08:48:10-05:00
Create Date                     : 2008:05:27 15:26:39-05:00
Metadata Date                   : 2008:05:28 08:48:10-05:00
Format                          : application/pdf
Title                           : untitled
Producer                        : Acrobat Distiller 8.1.0 (Macintosh)
Document ID                     : uuid:a7efd039-3db8-ca4c-8fad-2cefed4cef8a
Instance ID                     : uuid:542bd88e-f122-c049-bf1b-146a5a531e53
Page Count                      : 36
EXIF Metadata provided by EXIF.tools

Navigation menu