106533 Catalog

124916-Catalog 1 124916-Catalog_1 124916-Catalog_1 Batch9 unilog cesco-content

2014-09-27

: Pdf 106533-Catalog 106533-Catalog 783585 Batch8 unilog

Open the PDF directly: View PDF PDF.
Page Count: 18

K-1www.hubbell-wiring.com Wiring Device-Kellems
®
Section K
Ground Fault Products
Index
Product Page
Extra Heavy Duty Industrial and Hospital Grade GFCI Receptacles
Tamper-Resistant and Weather Resistant .........................K-2
Heavy Duty Commercial and Hospital Grade GFCI Receptacles
Tamper-Resistant and Weather Resistant .........................K-3
LED with Auto Grounding ......................................K-4
“Power Indicator” GFCI Receptacles .............................K-5
Pre-Wired/Leaded LED .......................................K-6
Tamper-Resistant and Weather Resistant Pre-Wired/Leaded LED ......K-6
Assembled in USA
LED .......................................................K-7
Tamper-Resistant and Weather Resistant LED .....................K-7
SNAPConnect® Commercial Grade GFCI Receptacles
Assembled in USA
LED with Auto Grounding ......................................K-9
Tamper-Resistant and Weather Resistant .........................K-9
GFCI Sensing Module, 50A Maximum Rating - NEMA 4X ............K-10
Straight Blade Portable GFCI Plugs ..............................K-11
Circuit Guard® Plug-In Portable GFCI and GFCI Tester ..............K-12
Portable GFCI Line Cords
Industrial Grade, Automatic and Manual Set ......................K-14
Commercial Grade, Automatic and Manual Set ...................K-15
Multiple Outlet Portable GFCI and GFCI Module ..................K-16
Hard Wired 30 Ampere GFCI - NEMA 4X ..........................K-17
Portable 30 Ampere GFCI - NEMA 4X ............................K-18
Tamper/Weather Resistant
GFCI Receptacles
GFCI Sensing Module
and Circuit Breaker
Pre-Wired/Leaded and
SNAPConnect® GFCI’s
Portable GFCI Products
www.hubbell-wiring.comK-2 Wiring Device-Kellems
®
Circuit Guard® GFCI Receptacles
Tamper-Resistant and Weather Resistant
Description Rating Color Catalog Number
Flush, polyester face,
back and side wired,
multiple drive screws.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Red
White
GFR5262BKTR
GFR5262TR
GFR5262GYTR
GFR5262ITR
GFR5262RTR
GFR5262WTR
GFR5362BKTR
GFR5362TR
GFR5362GYTR
GFR5362ITR
GFR5362RTR
GFR5362WTR
Hospital Grade
Flush, polyester face,
back and side wired,
multiple drive screws.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Red
White
GFR8200BKTR
GFR8200TR
GFR8200GYTR
GFR8200ITR
GFR8200RTR
GFR8200WTR
GFR8300BKTR
GFR8300TR
GFR8300GYTR
GFR8300ITR
GFR8300RTR
GFR8300WTR
Note: GFCI type receptacles should not be used in critical care patient areas or for electrical life support equipment applications because of
the possibility of power interruption. All GFCI receptacles listed above are furnished with both a matching color nylon wallplate,
and a SS26 302/304 super stainless steel wallplate. 20 amp feed-through capability.
See page Tech-10 for Tamper-Resistant and Weather Resistant descriptions.
AUTOGUARD® Self Test GFCI Receptacles
Tamper-Resistant and Weather Resistant
Description Rating Color Catalog Number
Flush, polyester face,
back and side wired,
multiple drive screws.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Red
White
GFR5262SGBK
GFR5262SG
GFR5262SGGY
GFR5262SGI
GFR5262SGR
GFR5262SGW
GFR5362SGBK
GFR5362SG
GFR5362SGGY
GFR5362SGI
GFR5362SGR
GFR5362SGW
Hospital Grade
Flush, polyester face,
back and side wired,
multiple drive screws.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Red
White
GFR8200SGBK
GFR8200SG
GFR8200SGGY
GFR8200SGI
GFR8200SGR
GFR8200SGW
GFR8300SGBK
GFR8300SG
GFR8300SGGY
GFR8300SGI
GFR8300SGR
GFR8300SGW
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
Ground Fault Products
Extra Heavy Duty Industrial & Hospital Grade GFCI Receptacles
Tamper-Resistant and Weather Resistant
GFR5262GYTR
GFR5262SG
10kA Short Circuit Current Rating
Limits improper access to energized contacts
Exclusive patented tamper-resistant
protection through switching technology
Continually tests and monitors for people
protection automatically
Patented self test diagnostics
Power indication
Steady “ON” GREEN LED provides
indication of power
Ground fault indicator
Steady “ON” RED LED provides visual
indication of a ground fault condition;
 ashingredindicatesdevicehaslost
capability to provide protection
No power at face if reverse wired
Open circuit condition eliminates false
assumption of protection at face
DurablefacewithV-0ammabilityrating
Polyester face cover
GFR5362SGI
Meets UL Standard 943
Class A GFCI
K-3www.hubbell-wiring.com Wiring Device-Kellems
®
GFTR20W3
Circuit Guard® GFCI Receptacles
Tamper-Resistant and Weather Resistant
Description Rating Color Catalog Number
Flush, nylon face,
back and side wired,
multiple drive screws,
self-grounding staple.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFTR15BK
GFTR15
GFTR15GY
GFTR15I
GFTR15LA
GFTR15R
GFTR15W
GFTR20BK
GFTR20
GFTR20GY
GFTR20I
GFTR20LA
GFTR20R
GFTR20W
Circuit Guard® GFCI Receptacles - 3 Pack
Tamper-Resistant and Weather Resistant
Description Rating Color Catalog Number
3 Pack, flush, nylon face,
back and side wired,
multiple drive screws,
self-grounding staple.
15 and 20A
125V AC
Ivory
Light Almond
White
GFTR15I3
GFTR15LA3
GFTR15W3
GFTR20I3
GFTR20LA3
GFTR20W3
Note: Consult factory for availability of other colors.
Circuit Guard® GFCI Receptacles
Tamper-Resistant and Weather Resistant
Description Rating Color Catalog Number
Hospital Grade
Flush, nylon face,
back and side wired,
multiple drive screws,
self-grounding staple.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFR8200HBKTR
GFR8200HTR
GFR8200HGYTR
GFR8200HITR
GFR8200HL ATR
GFR8200HRTR
GFR8200HWTR
GFR8300HBKTR
GFR8300HTR
GFR8300HGYTR
GFR8300HITR
GFR8300HLATR
GFR8300HRTR
GFR8300HWTR
Note: GFCI type receptacles should not be used in critical care patient areas or for electrical life support equipment applications because of
the possibility of power interruption. All GFCI receptacles listed above are furnished with a matching color nylon wallplate. 20 amp
feed-through capability.
See page Tech-10 for Tamper-Resistant and Weather Resistant descriptions.
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
Ground Fault Products
Heavy Duty Commercial & Hospital Grade GFCI Receptacles
Tamper-Resistant and Weather Resistant with Auto Grounding
GFTR15AL
GFR8300HRTR
GFTR20I
10kA Short Circuit Current Rating
Limits improper access to energized contacts
Patented shutter design for tamper-
resistant protection
No power at face if reverse wired
Open circuit condition eliminates false
assumption of protection at face
Ground fault EOL indicator
Flashing RED indicates device has lost
capability to provide protection
Accepts fork terminals
Open terminal design
Installation ease
Internal back wiring
Automatic self-grounding staple
Captive mounting screws
Meets UL Standard 943
Class A GFCI
www.hubbell-wiring.comK-4 Wiring Device-Kellems
®
Ground Fault Products
Heavy Duty Commercial & Hospital Grade GFCI Receptacles
LED with Auto Grounding
Hospital Grade
Circuit Guard® GFCI Receptacles
Description Rating Color Catalog Number
Flush, nylon face,
back and side wired,
multiple drive screws,
self-grounding staple.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFR8200HBKLA
GFR8200HLA
GFR8200HGYLA
GFR8200HILA
GFR8200HLAA
GFR8200HRLA
GFR8200HWLA
GFR8300HBKLA
GFR8300HLA
GFR8300HGYLA
GFR8300HILA
GFR8300HLAA
GFR8300HRLA
GFR8300HWLA
Note: GFCI type receptacles should not be used in critical care patient areas or for electrical life support equipment applications because of
the possibility of power interruption. All GFCI receptacles listed above are furnished with a matching color nylon wallplate. 20 amp
feed-through capability.
Circuit Guard® GFCI Receptacles
Description Rating Color Catalog Number
Flush, nylon face,
back and side wired,
multiple drive screws,
self-grounding staple.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GF15BKLA
GF15LA
GF15GYLA
GF15ILA
GF15LALA
GF15RLA
GF15WLA
GF20BKLA
GF20LA
GF20GYLA
GF20ILA
GF20LALA
GF20RLA
GF20WLA
GF15ALLA
GFR8200HRLA
10kA Short Circuit Current Rating
Comprehensive diagnostics
When test button is actuated, both the
electronic components and mechanical
trip mechanism are functionally tested
Ground fault EOL indicator
Flashing RED indicates device has lost
capability to provide protection
No power at face if reverse wired
Open circuit condition eliminates false
assumption of protection at face
Installation ease
Internal back wiring
Automatic self-grounding staple
Captive mounting screws
GF15ILA
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
Meets UL Standard 943
Class A GFCI
Circuit Guard® GFCI Receptacles - 3 Pack
Description Rating Color Catalog Number
3 Pack, flush, nylon face,
back and side wired,
multiple drive screws,
self-grounding staple.
15 and 20A
125V AC
Ivory
Light Almond
White
GF15ILA3
GF15LALA3
GF15WLA3
GF20ILA3
GF20LALA3
GF20WLA3
Note: Consult factory for availability of other colors.
GF20WLA3
K-5www.hubbell-wiring.com Wiring Device-Kellems
®
Ground Fault Products
Heavy Duty Commercial GFCI Receptacles
LED with Auto Grounding
Circuit Guard® Bulk Pack GFCI Receptacles
Description Rating Color Catalog Number
Flush, nylon face,
back and side wired,
multiple drive screws,
self-grounding staple.
Bulk packed, (50 pieces
without wallplate).
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GF15BKLABULK
GF15LABULK
GF15GYLABULK
GF15ILABULK
GF15LALABULK
GF15RLABULK
GF15WLABULK
GF20BKLABULK
GF20LABULK
GF20GYLABULK
GF20ILABULK
GF20LALABULK
GF20RLABULK
GF20WLABULK
GF15BKLABULK
GFBF20ILA
GFCI Receptacle Specifications per GFCI Products Listed (Pages K-2 to K-9)
Trip Level 4 to 6 mA.
Trip Time .025 second nominal.
Frequency 60 Hz.
Voltage 120V AC +10% - 15% (102V to 132V).
Amperage 15A/20A, 20A Feed Thru.
Maximum Interrupting Capacity 10,000A.
Operating Temperature -35°C to 66°C or -30°F to 150°F.
Maximum Humidity 95%.
Listings and Standards Meets UL498 for receptacles, UL943 Class A for GFCIs UL File E41978.
CSA Certified.
Codes Meets all NEC® and CEC requirements. NEMA WD-6 ANSI 73.
NEC® is a registered trademark of the National Fire Protection Association (NFPA).
Combination Switch/GFCI
Description Rating Color Catalog Number
Single-pole switch,
GFCI grounding receptacle,
back and side wired, matching
nylon wallplate included.
15A 120V
(Switch)
15A 125V
(Receptacle)
Ivory
Light Almond
White
GFSP15IC
GFSP15LAC
GFSP15WC
Circuit Guard® Faceless GFCI
Description Rating Color Catalog Number
Faceless, nylon top,
back and side wired,
multiple drive screws,
self-grounding staple.
20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFBF20BKLA
GFBF20LA
GFBF20GYLA
GFBF20ILA
GFBF20LALA
GFBF20RLA
GFBF20WLA
Note: GFCI type receptacles should not be used in critical care patient areas or for electrical life support equipment applications because of
the possibility of power interruption. All GFCI receptacles listed above are furnished with a matching color nylon wallplate.
GFSP15WC
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
Meets UL Standard 943
Class A GFCI
“Power Indicator” GFCI Receptacles
Description Rating Color Catalog Number
Commercial GFR,
Power LED Indicator.
15 and 20A
125V AC
Ivory
White
Red
GF15ILS
GF15WLS
GF15RLS
GF20ILS
GF20WLS
GF20RLS
Hospital Grade, Commercial GFR,
Power LED Indicator.
15 and 20A
125V AC
Ivory
White
Red
GFR8200HILS
GFR8200HWLS
GFR8200HRLS
GFR8300HILS
GFR8300HWLS
GFR8300HRLS
Commercial GFR, Power LED
Indicator, Tamper and Weather
Resistant.
15 and 20A
125V AC
Ivory
White
Red
GFTR15IS
GFTR15WS
GFTR15RS
GFTR20IS
GFTR20WS
GFTR20RS
Hospital Grade, Commercial GFR,
Power LED Indicator, Tamper and
Weather Resistant.
15 and 20A
125V AC
Ivory
White
Red
GFR8200HITRS
GFR8200HWTRS
GFR8200HRTRS
GFR8300HITRS
GFR8300HWTRS
GFR8300HRTRS
Note: Please consult factory for availability of other colors and/or non Tamper-Resistant GFCI versions.
See page Tech-10 for Tamper-Resistant and Weather Resistant descriptions.
GFTR15IS
www.hubbell-wiring.comK-6 Wiring Device-Kellems
®
Ground Fault Products
Heavy Duty Commercial & Hospital Grade GFCI Receptacles
Pre-Wired/Leaded LED
GFCI LED Pre-Wired/Leaded,
#12 Solid Wire, 8 Inch Leads
Description Rating Color* Catalog Number
Impact resistant ush nylon face,
LED, self-grounding staple,
8" solid wire leads.
15 and 20A
125V AC
Gray
Ivory
White
GF15GYLAP1
GF15ILAP1
GF15WLAP1
GF20GYLAP1
GF20ILAP1
GF20WLAP1
Note: *Consult factory for additional colors.
GFCI LED Pre-Wired/Leaded,
#12 Stranded Wire, 8 Inch Leads
Description Rating Color* Catalog Number
Impact resistant ush nylon face,
LED, self-grounding staple,
8" stranded wire leads.
15 and 20A
125V AC
Gray
Ivory
White
GF15GYLAP2
GF15ILAP2
GF15WLAP2
GF20GYLAP2
GF20ILAP2
GF20WLAP2
Note: *Consult factory for additional colors.
GFCI LED Tamper and Weather Resistant
Pre-Wired/Leaded, #12 Solid Wire, 8 Inch Leads
Description Rating Color* Catalog Number
Tamper and Weather Resistant,
impact resistant ush nylon face,
LED, self-grounding staple,
8" solid wire leads.
15 and 20A
125V AC
Gray
Ivory
White
GFTR15GYP1
GFTR15IP1
GFTR15WP1
GFTR20GYP1
GFTR20IP1
GFTR20WP1
Note: *Consult factory for additional colors.
See page Tech-10 for Tamper-Resistant and Weather Resistant descriptions.
GFCI LED Tamper and Weather Resistant
Pre-Wired/Leaded, #12 Stranded Wire, 8 Inch Leads
Description Rating Color* Catalog Number
Tamper and Weather Resistant,
impact resistant ush nylon face,
LED, self-grounding staple,
8" stranded wire leads.
15 and 20A
125V AC
Gray
Ivory
White
GFTR15GYP2
GFTR15IP2
GFTR15WP2
GFTR20GYP2
GFTR20IP2
GFTR20WP2
Note: *Consult factory for additional colors.
See page Tech-10 for Tamper-Resistant and Weather Resistant descriptions.
Applications
GFTR20GYP2
GFTR15WP1
GF15GYLAP1
GF20ILAP2
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
Meets UL Standard 943
Class A GFCI
K-7www.hubbell-wiring.com Wiring Device-Kellems
®
Ground Fault Products
Heavy Duty Commercial & Hospital Grade LED GFCI Receptacles
Assembled in USA
GFCI LED,
Assembled in USA
Description Rating Color Catalog Number
Impact resistant ush nylon face,
back and side wired, LED,
self-grounding staple.
Assembled in the USA.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GF15BKLU
GF15LU
GF15GYLU
GF15ILU
GF15LALU
GF15RLU
GF15WLU
GF20BKLU
GF20LU
GF20GYLU
GF20ILU
GF20LALU
GF20RLU
GF20WLU
GFCI LED Hospital Grade ,
Assembled in USA
Description Rating Color Catalog Number
Hospital Grade, impact resistant
ush nylon face, back and side wired,
LED, self-grounding staple.
Assembled in the USA.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFR8200HBKLU
GFR8200HLU
GFR8200HGYLU
GFR8200HILU
GFR8200HLALU
GFR8200HRLU
GFR8200HWLU
GFR8300HBKLU
GFR8300HLU
GFR8300HGYLU
GFR8300HILU
GFR8300HLALU
GFR8300HRLU
GFR8300HWLU
GFCI LED Tamper and Weather Resistant,
Assembled in USA
Description Rating Color Catalog Number
Tamper and Weather Resistant,
impact resistant ush nylon face,
back and side wired, LED,
self-grounding staple.
Assembled in the USA.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFTR15BKU
GFTR15U
GFTR15GYU
GFTR15IU
GFTR15LAU
GFTR15RU
GFTR15WU
GFTR20BKU
GFTR20U
GFTR20GYU
GFTR20IU
GFTR20LAU
GFTR20RU
GFTR20WU
GFCI LED Hospital Grade ,
Tamper and Weather Resistant, Assembled in USA
Description Rating Color Catalog Number
Hospital Grade, Tamper and
Weather Resistant, impact resistant
ush nylon face, back and side wired,
LED, self-grounding staple.
Assembled in the USA.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFR8200HBKTRU
GFR8200HTRU
GFR8200HGYTRU
GFR8200HITRU
GFR8200HL ATRU
GFR8200HRTRU
GFR8200HWTRU
GFR8300HBKTRU
GFR8300HTRU
GFR8300HGYTRU
GFR8300HITRU
GFR8300HLATRU
GFR8300HRTRU
GFR8300HWTRU
Note: Many of the products listed on this page are assembled in USA and many are Buy American Compliant. Please contact Hubbell
for specific certification requirements.
See page Tech-10 for Tamper-Resistant and Weather Resistant descriptions.
GFTR20IU
GF15GYLU
GFR8300HLATRU
GFR8300HWLU
Applications
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
Meets UL Standard 943
Class A GFCI
The products listed on this page are Assembled in USA, and many are Buy American
Compliant. Please contact Hubbell with any certication requirements.
www.hubbell-wiring.comK-8 Wiring Device-Kellems
®
Ground Fault Products
SNAPConnect® Commercial Grade GFCI Receptacles
Assembled in USA
Labor Savings Feature!
Installation ease
Self-grounding staple
Audible SNAP, indicates solid connection
Secure, easy grip latch
Inspection of power contacts
Clear terminal housing
No exposed metal
Requires minimal box space
Compact size
Clean nished look
GFR20SNAPINASNAP1RNA
No Special Tester Required
.085 inch keyhole accepts the
probe points found on the most
common voltage testers and
digital multi-meters
Save one Minute!
Rough-in the SNAPConnect®
terminal instead of pigtails.
Complete Trim-Out
in Less Than One Minute!
Secure mounting screws, attach
wallplate, job complete.
Save Over Three Minutes!
Remove protective packaging
and SNAPConnect® device to
the circuit.
Meets UL Standard 943
Class A GFCI
Audible SNAP, indicates solid connection
Many of these products are Assembled in USA, as indicated, and many are Buy American Compliant.
Please contact Hubbell with any certication requirements.
K-9www.hubbell-wiring.com Wiring Device-Kellems
®
Ground Fault Products
SNAPConnect® Commercial Grade GFCI Receptacles
Assembled in USA
SNAPConnect® GFCI LED,
Assembled in USA
Description Rating Color
Commercial Grade
15A GFCI
Commercial Grade
20A GFCI
SNAPConnect GFCI LED,
self-grounding staple,
requires connector below,
sold separately.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFR15SNAPBKNA
GFR15SNAPNA
GFR15SNAPGYNA
GFR15SNAPINA
GFR15SNAPLANA
GFR15SNAPRNA
GFR15SNAPWNA
GFR20SNAPBKNA
GFR20SNAPNA
GFR20SNAPGYNA
GFR20SNAPINA
GFR20SNAPLANA
GFR20SNAPRNA
GFR20SNAPWNA
SNAPConnect® GFCI LED Hospital Grade ,
Assembled in USA
Description Rating Color
Hospital Grade
15A GFCI
Hospital Grade
20A GFCI
Hospital Grade ,
SNAPConnect GFCI LED,
self-grounding staple,
requires connector below,
sold separately.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFR8200SNAPBKNA
GFR8200SNAPNA
GFR8200SNAPGYNA
GFR8200SNAPINA
GFR8200SNAPLANA
GFR8200SNAPRNA
GFR8200SNAPWNA
GFR8300SNAPBKNA
GFR8300SNAPNA
GFR8300SNAPGYNA
GFR8300SNAPINA
GFR8300SNAPLANA
GFR8300SNAPRNA
GFR8300SNAPWNA
SNAPConnect® GFCI LED
Tamper and Weather Resistant, Assembled in USA
Description Rating Color
Commercial Grade
15A GFCI
Commercial Grade
20A GFCI
SNAPConnect GFCI TR/WR,
self-grounding staple,
requires connector below,
sold separately.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFTR15SNAPBKNA
GFTR15SNAPNA
GFTR15SNAPGYNA
GFTR15SNAPINA
GFTR15SNAPLANA
GFTR15SNAPRNA
GFTR15SNAPWNA
GFTR20SNAPBKNA
GFTR20SNAPNA
GFTR20SNAPGYNA
GFTR20SNAPINA
GFTR20SNAPLANA
GFTR20SNAPRNA
GFTR20SNAPWNA
SNAPConnect® GFCI LED Hospital Grade ,
Tamper and Weather Resistant, Assembled in USA
Description Rating Color
Hospital Grade
15A GFCI
Hospital Grade
20A GFCI
Hospital Grade, SNAPConnect
GFCI TR/WR, self-grounding
staple, requires connector
below, sold separately.
15 and 20A
125V AC
Black
Brown
Gray
Ivory
Light Almond
Red
White
GFTR8200SNAPBKNA
GFTR8200SNAPNA
GFTR8200SNAPGYNA
GFTR8200SNAPINA
GFTR8200SNAPLANA
GFTR8200SNAPRNA
GFTR8200SNAPWNA
GFTR8300SNAPBKNA
GFTR8300SNAPNA
GFTR8300SNAPGYNA
GFTR8300SNAPINA
GFTR8300SNAPLANA
GFTR8300SNAPRNA
GFTR8300SNAPWNA
GFR15SNAPGYNA
GFR8300SNAPRNA
GFTR20SNAPINA
GFTR8300SNAPWNA
SNAP1RNA
15A 125V
NEMA 5-15R
UL CSA
0.5 HP
20A 125V
NEMA 5-20R
UL CSA
1 HP
Meets UL Standard 943
Class A GFCI
SNAPConnect® Right Angle Pigtailed Terminal
Description Wire Type
General Use
Catalog Number
Assembled in USA
Catalog Number
Clear right angle terminal with 6 inch leads,
600V, #12 AWG THHN/THWN-2,
Polycarbonate housing material.
Solid
Stranded
SNAP1RA
SNAP2RA
SNAP1RNA
SNAP2RNA
Note: See page Tech-10 for Tamper-Resistant and Weather Resistant descriptions.
Many of these products are Assembled in USA, as indicated, and many are Buy
American Compliant. Please contact Hubbell with any certication requirements.
www.hubbell-wiring.comK-10 Wiring Device-Kellems
®
Ground Fault Products
GFCI Sensing Module, 50A Maximum Rating - NEMA 4X
Typical Applications Include:
Power Generators, Spas, High Pressure Washers, Power Centers, Reneries and Mobile Power.
The sensing module functions interdependently with a magnetic branch circuit breaker. The module monitors the electrical
circuit by use of an external differential current transformer. No direct load is present at the module. In the event of a ground
fault, the load is interrupted by way of the hydraulic magnetic circuit breaker utilizing a shunt trip coil.
This line of Sensing Modules is rated from 1 to 50 Amps and circuit current-carrying conductors from 1 to 3 poles.
Product is available with an automatic or manual “safe start” reset feature. The enclosure, when mounted with the supplied
gasket, achieves a UL NEMA 4X Rating. This module and breaker system is ideal for portable generator integration protecting
all outlets on a generator. This system meets the proposed requirements for generators Underwriters Laboratory Standard
2201. UL/cUL 943 Listed, Class A 4-6mA trip level and UL 1053 Compliant.
GFCI Sensing Module – 50A Maximum
Description Catalog Number
120V AC Sensing Module Auto GFSM120A
120V AC Sensing Module Manual GFSM120M
240V AC Sensing Module Auto GFSM240A
240V AC Sensing Module Manual GFSM240M
Wiring Schematics
GFSM120M
GFSMCB120401P
SPLIT PHASE 120/240VAC (L1, L2, N, GRND)
YELLOW (SHUNT)
BLACK
WHITE
L1
L2
LOAD
LINE
N
GROUND
120VAC GFCI
SENSING
MODULE
CIRCUIT
BREAKER
NO
C
PART #
AUTO GFSM120A
MAUUAL GFSM120M
Current carrying leads must
be twisted as they go through
the sensing module.
G
LOAD--->
120/
240V AC
IN
GFSMCB120240xx3P
L1
N
L2
CIRCUIT
BREAKER
120VAC GFCI
SENSING
MODULE
GROUND
SINGLE PHASE 120VAC (HOT, NEUTRAL, GRND)
YELLOW (SHUNT)
BLACK
WHITE
N
H
LOAD
LINE
NO
C
ORANGE
SHUNT
JUMPER
ORANGE
SHUNT
JUMPER
ORANGE
SHUNT
JUMPER
PART #
AUTO GFSM120A
MAUUAL GFSM120M
Current carrying leads must
be twisted as they go through
the sensing module.
G
N
GFSMCB120xx1P
LOAD--->
H
120V AC
IN
LINE
LOAD
L1
L2
RED
BLACK
YELLOW (SHUNT)
SINGLE PHASE 240VAC (L1, L2, GRND)
GROUND
240VAC GFCI
SENSING
MODULE
CIRCUIT
BREAKER
NO
C
PART #
AUTO GFSM240A
MAUUAL GFSM240M
Current carrying leads must
be twisted as they go through
the sensing module.
G
240V AC
IN
L2
L1
GFSMCB240xx2P
LOAD--->
GFCI Sensing Module Circuit Breakers
Catalog Number Configurator
Example Catalog Numbers: GFSMCB120401P:
GFSMCB240502P:
GFSMCB120240203P:
120V, 40A, 1 Pole
240V, 50A, 2 Pole
120/240V, 20A, 3 Pole
Ground Fault Sensing
Module Circuit Breaker A/C Voltage Amperage
Number
of Poles Sensing Module Required
GFSMCB
120
1 to 50
1GFSM120A or M
120 2GFSM120A or M
240 2GFSM240A or M
2GFSM120A or M120/240
120/240 3GFSM120A or M
1.60"
(40.6)
4.95"
(125.7)
2.21"
(56.1)
1.35"
(34.3)
.81"
(20.5)
GFP515A
GFP5266CY
K-11www.hubbell-wiring.com Wiring Device-Kellems
®
Circuit Guard® Wired On Industrial Portable GFCI Plug
Description Rating Catalog Number
GFCI plug, manual set, black. 2 pole, 3 wire grounding,
15A, 125V, NEMA 5-15P.
GFP5266C
GFCI plug, manual set, yellow. 2 pole, 3 wire grounding,
15A, 125V, NEMA 5-15P.
GFP5266CY
GFCI plug with 1 foot line cord,
manual set, yellow, with
connector body.
2 pole, 3 wire grounding,
15A, 125V, NEMA 5-15P, NEMA 5-15R.
GFP1C
Circuit Guard® Wired On Commercial Portable GFCI Plug
Description Rating Catalog Number
GFCI plug, automatic set
field wireable, black.
2 pole, 3 wire grounding,
15A, 125V, NEMA 5-15P.
GFP515A
GFCI plug, manual set
field wireable, black.
2 pole, 3 wire grounding,
15A, 125V, NEMA 5-15P.
GFP515M
Specifications
Trip Level
Trip Time
Frequency
Voltage
Amperage
Maximum Interrupting Capacity
Operating Temperature
Maximum Humidity
Housing
Input
Cord Range
Cord Type: Length (GFP1C)
Power “ON” Indication
Listings
Codes
4 to 6 mA.
.025 sec. nominal.
60 Hz.
120V AC +10% – 15%. Incorporates no voltage release feature.
15A.
2000A.
-35°C to 66°C or -30°F to 150°F.
95%.
High-impact, UV stabilized material. UL 94V-0 flammability classification.
N E M A 5 -15 P.
16/3 – 12/3 Type SJ, 18/3 – 12/3 Type S.
14/3 Type SJTW-A (UL), SJTW (CSA); 1 foot; NEMA 5-15R.
Indicator light.
Meets UL943 Class A Listed, CSA Certified.
Meets all NEC® and CEC requirements.
Ground Fault Products
Straight Blade Portable GFCI Plugs
15 Ampere, 120 Volts AC, 2 Pole, 3 Wire Grounding
Dimensions
GFP515 SeriesGFP5266C Series
Dimensions in Inches (mm)NEC® is a registered trademark of the National Fire Protection Association (NFPA).
GFP315A
GFT2G
www.hubbell-wiring.comK-12 Wiring Device-Kellems
®
Ground Fault Products
Circuit Guard® Plug-In Portable GFCI and GFCI Tester
15 Ampere, 120 Volts AC, 2 Pole, 3 Wire Grounding
NEC® is a registered trademark of the National Fire Protection Association (NFPA).
FAULT
LIGHT
RESET TEST
5.50
(139.7)
3.45
(87.6)
5.83
(148.0)
1.50
(38.1)
.82
(20.8)
1.76
(44.7)
Dimensions in Inches (mm)
Circuit Guard® Plug-In Portable GFCI
Description Rating Catalog Number
Three outlet plug-in. 15A, 120V AC GFP315A
Specifications
GFP315A
Trip Level
Trip Time
Frequency
Voltage
Amperage
Maximum Interrupting Capacity
Operating Temperature
Maximum Humidity
Housing
Input
Output
Fault Indication
Center Screw
Listings and Standards
Codes
4 to 6 mA.
.025 sec. nominal.
60 Hz.
120V AC +10% – 15%. Incorporates no voltage release feature.
15A.
2000A.
-35°C to 66°C or -30°F to 150°F.
95%.
High-impact ABS.
N E M A 5 -15 P.
3 NEMA 5-15R.
Indicator light.
For optional permanent mounting.
Meets UL498 for receptacles, UL943 Class A for GFCIs UL File E41978,
CSA Certified.
Meets all NEC® and CEC requirements.
GFCI Tester
Description Rating Catalog Number
Ground fault tester. 120V AC GFT2G
Designed to measure the trip level of portable or “wired-in” GFCI’s in a range of 2-7mA.
Leakage level can be adjusted from 2-7mA.
Ideal for measuring leakage level of GFCI breakers, GFCI portables and GFCI receptacles.
Dimensions
K-13www.hubbell-wiring.com Wiring Device-Kellems
®
Ground Fault Products
Portable GFCI Line Cords
Features and Benefits
Circuit Guard® Set GFCI Line Cord
Portable GFCI Line Cords provide ground fault protection both indoors and out. They interrupt electrical power for
equipment loads when leakage to ground is 4-6 milliamperes. Available in lengths of 18" (45.7 cm), 6' (182.9 cm), and
25' (762 cm). A 15' (457.2 cm) OEM version with stripped leads is also available. They are offered with an Automatic Set
or Manual Set feature to meet your application.
Available in Automatic Set with yellow base or Manual Set with black base.
High impact UV stabilized
housing resists dust, sunlight
and chemicals for long life
Heavy-duty molded plug
and connector for reliable
connection
Solid (not formed) plug
blades are crimped and
soldered for a better
connection and longer life
GFP4C15M
One-piece flush sealed
keypads for greater
reliability and resistance
to damage due to impact
All-glass circuit board provides
superior moisture immunity
Heavy-duty molded strain
relief prevents conductor
strain and resulting failure
Bright fault indicator light
provides fault confirmation
from a distance
Watertight GFCI housing for
use in harsh environments
GFP4C15A
GFP3C20MTL
GFPOEMM
GFP25C15A
GFP6C15M
www.hubbell-wiring.comK-14 Wiring Device-Kellems
®
Automatic Set GFCI
Automatically energizes or sets the GFCI for use upon
plug in and after the loss of primary power (power failure
or unplugging the device). After a ground fault condition,
unit must be reset by pushing the reset button. This
feature eliminates the need for unit to be reset each time it
is plugged in or powered up. Ideal for equipment intended
for continuous use where a temporary power failure is
likely and undesirable. Examples are pumps, pressure
washers, portable signs or lighting and engine heaters.
Manual Set GFCI
Requires the GFCI to be manually set for use by pressing
the reset button upon plug in and after loss of primary
power (power failure or unplugging the device). Must
be manually reset after a ground fault condition. Ideal
for applications where operator injury might occur if
equipment were to restart after a power failure. Typical
equipment includes power drills, saws, lathes and grinders.
IP21
SUITABILITY
Ground Fault Products
Portable GFCI Line Cords
Industrial Grade, Automatic and Manual Set
Straight Blade Twist-Lock®
Input 15A NEMA 5-15P,
20A NEMA 5-20P.
15A NEMA L5-15P HBL47CM20C,
20A NEMA L5-20P HBL23CM11.
Output 15A NEMA 5-15R (except GFPOEMM),
20A NEMA 5-20R.
15A NEMA L5-15R HBL47CM29C,
20A NEMA L5-20R HBL23CM13.
Circuit Guard® Automatic Set
Portable GFCI Line Cords 15A 120V AC
Description Catalog Number
18" (45.7 cm) GFCI line cord. GFP4C15A
6' (182.9 cm) GFCI line cord. GFP6C15A
25' (762.0 cm) GFCI line cord. GFP25C15A
15' (457.2 cm) GFCI power supply cord with stripped leads. GFPOEMA*
Circuit Guard® Manual Set
Portable GFCI Line Cords 15A 120V AC 20A 120V AC
Description Catalog Number
18" (45.7 cm) GFCI line cord. GFP4C15M
3' (91.4 cm) GFCI line cord. GFP3C20M
6' (182.9 cm) GFCI line cord. GFP6C15M
25' (762.0 cm) GFCI line cord. GFP25C15M
15' (457.2 cm) GFCI power supply cord with stripped leads. GFPOEMM*
50' (1524.0 cm) GFCI power supply with Elastogrip®
watertight straight blade.
GFP50C15WM
100' (3048.0 cm) GFCI power supply with Elastogrip®
watertight straight blade.
GFP100C15WM
Note: *Total length is 15' 4.5" (468.6 cm) including leads: green 4.5" (114.3), black and white 3.5" (88.9). Each pre-stripped .375" (9.5).
Circuit Guard® Manual Set
Twist-Lock Portable GFCI Line Cords 15A 120V AC 20A 120V AC
Description Catalog Number
3' (91.4 cm) GFCI line cord. GFP3C15MTL GFP3C20MTL
NEC® is a registered trademark of the National Fire Protection Association (NFPA).
Specifications
Portable GFCI Line Cords
Trip Level
Trip Time
Frequency
Voltage
Amperage
Maximum Interrupting Capacity
Operating Temperature
Maximum Humidity
Housing
Cord Type
Visual Fault Indication Light On
Listing and Standards
Codes
4 to 6 mA.
.025 sec. nominal.
60 Hz.
120V AC +10% – 15%. Incorporates no voltage release feature.
15A /20A.
2000A.
-35°C to 66°C or -30°F to 150°F.
95%.
High-impact, UV stabilized PVC. UL 94V-0 flammability classification.
Meets UL and CSA watertight requirements. Adhesive bonded.
14/3 SJTW-A (UL), SJTW (CSA). Except GFP3C20M, GFP3C15MTL and
GFP3C20MTL are 12/3 SJTW.
Indicates fault.
Meets UL943 Class A, UL File E41978, CSA Certified.
Meets all NEC® and CEC requirements.
GFP2TTA
GFPIL20125LKM
GFPIL20125LKA
GFPIL15125TRIM
GFP15LA
GFP2CA
K-15www.hubbell-wiring.com Wiring Device-Kellems
®
Ground Fault Products
Portable GFCI Line Cords
Commercial Grade, Automatic and Manual Set
Circuit Guard® Portable GFCI Single Outlet - 12/3 SJEOW 15A 120V AC
Description Catalog Number
2' (60.9 cm) GFCI line cord, automatic set. GFP2CA
2' (60.9 cm) GFCI line cord, manual set. GFP2CM
25' (762.0 cm) GFCI line cord, automatic set. GFP25CA
25' (762.0 cm) GFCI line cord, manual set. GFP25CM
Circuit Guard® Portable GFCI Triple Tap Outlet - 12/3 SJEOW 15A 120V AC
Description Catalog Number
2' (60.9 cm) GFCI line cord, automatic set. GFP2TTA
2' (60.9 cm) GFCI line cord, manual set. GFP2TTM
25' (762.0 cm) GFCI line cord, automatic set. GFP25TTA
25' (762.0 cm) GFCI line cord, manual set. GFP25TTM
Circuit Guard® OEM Equipment Integrated Cord Sets - 14/3 SJEOW 15A 120V AC
Description Catalog Number
15' (457.2 cm) GFCI with flying leads, automatic set. GFP15LA
15' (457.2 cm) GFCI with flying leads, manual set. GFP15LM
35' (1066.8 cm) GFCI with flying leads, automatic set. GFP35LA
35' (1066.8 cm) GFCI with flying leads, manual set. GFP35LM
15A GFCI In Line GFCI, Single and Triple Tap - 12/3 SJTW 15A 120V AC
Description Catalog Number
2' (60.9 cm), 5-15 single tap, automatic set. GFPIL15125A
2' (60.9 cm), 5-15 single tap, manual set. GFPIL15125 M
2' (60.9 cm), 5-15 triple tap, automatic set. GFPIL15125TRIA
2' (60.9 cm), 5-15 triple tap, manual set. GFPIL15125TRIM
20A GFCI In Line GFCI, Locking - 12/3 SJTW 20A 120V AC
Description Catalog Number
2' (60.9 cm), L5-20 locking, automatic set. GFPIL20125LKA
2' (60.9 cm), L5-20 locking, manual set. GFPIL20125LKM
20A GFCI In Line GFCI, Locking - 12/3 SJTW 20A 250V AC
Description Catalog Number
2' (60.9 cm), L6-20 locking, automatic set. GFPIL20250LKA
2' (60.9 cm), L6-20 locking, manual set. GFPIL20250LKM
NEC® is a registered trademark of the National Fire Protection Association (NFPA).
Specifications
Portable GFCI Line Cords
Trip Level
Trip Time
Frequency
Voltage
Amperage
Maximum Interrupting Capacity
Operating Temperature
Maximum Humidity
Housing
Visual Fault Indication Light On
Listing and Standards
Codes
4 to 6 mA.
.025 sec. nominal.
60 Hz.
120/250V AC +10% - 15%. Incorporates no voltage release feature.
15A /20A.
2000A.
-35°C to 66°C or -30°F to 150°F.
95%.
High-impact, UV stabilized PVC. UL 94V-0 flammability classification.
Meets UL and CSA watertight requirements. Adhesive bonded.
Indicates fault.
Meets UL943 Class A, UL File E41978, CSA Certified.
Meets all NEC® and CEC requirements.
GFP15M
GFM20
www.hubbell-wiring.comK-16 Wiring Device-Kellems
®
Multiple Outlet Portable GFCI
Description Rating Receptacles Plug Catalog Number
4 outlet,
manual set, yellow.
15A, 120V AC (2) Duplex 5-15R NEMA 5 -15P GFP15M
4 outlet,
manual set, yellow.
20A, 120V AC (2) Duplex 5-20R NEMA 5-20P GFP20M
GFCI Module - UL Type 3R Rated
Description Rating Catalog Number
GFCI module,
manual set, yellow.
20A, 120V AC, 60 Hz GFM20
GFCI module,
auto set, yellow.
20A, 120V AC, 60 Hz GFM20A
IP21
SUITABILITY
Specifications
GFP15M / GFP20M GFM20 / GFM20A
Trip Level 4 to 6 mA. 4 to 6 mA.
Trip Time .025 sec. nominal. .025 sec. nominal.
Frequency 60 Hz. 60 Hz.
Voltage 120V AC +10% - 15%. 120V AC +10% - 15%.
No voltage release feature. No voltage release feature.
Maximum Interrupting Capacity 5000A. 5000A.
Current 15A / 20A. 20A / 20A Feed-through.
Operating Temperature -35°C to 66°C or -30°F to 150°F. -35°C to 66°C or -30°F to 150°F.
Housing Rating High-impact, yellow Valox® High-impact, UV stabilized, rigid PVC.
with protective lift covers. UL 94V-0 flammability classification.
UL Type 3R Rated.
Input 5-15P, 15A / 5-20P, 20A. IP21 Suitability. #12 AWG stranded conductors (black/white/green).
Output 5-15R(4), 15A / 5-20R(4), 20A. #12 AWG stranded conductors (red/gray).
Power Supply Cord 6' (182.9 cm) STOW-A (STW FT2 CSA). N/A.
Mounting Screws N/A. Self-tapping, combination, #6-32.
Power “ON” Indication LED indicator light. LED indicator light.
Agency Approvals UL Listed, UL498 for receptacles. UL Listed, CSA Certified.
Meets UL943 Class A for GFCI’s. Meets UL943 Class A for GFCI’s.
Codes Meets all NEC® and CEC requirements. Meets all NEC® and CEC requirements.
Ground Fault Products
Portable GFCI Line Cords
Multiple Outlet Portable GFCI and GFCI Module
Valox® is a trademark of SABIC Innovative Plastics, acquired from General Electric Company.
NEC® is a registered trademark of the National Fire Protection Association (NFPA).
Manual Reset GFCI
Automatic Reset GFCI
K-17www.hubbell-wiring.com Wiring Device-Kellems
®
Ground Fault Products
Hard Wired 30 Ampere GFCI - NEMA 4X
Circuit Guard® Hard Wired 30A GFCI - UL Type 4X Rated
Description Voltage Alarm Manual Set Automatic Set
Hard wired, manual set
and automatic set GFCIs.
120V AC None GFHW13005 GFHW13105
120V AC Audible GFHW13015 GFHW13115
240V AC None GFHW23005 GFHW23105
240V AC Audible GFHW23015 GFHW2 3115
120/240V AC Audible GFHW33015 GFHW33115
3Ø 250V AC None GFHW530 GFHW531
3Ø 120/208V AC None GFHW430 GFHW431
Note: All units above are stock items.
Specifications
Electrical Ratings
Rated Voltage 120V AC, 240V AC and 120/240V, 3Ø 250V AC, 3Ø 120/208V AC.
Operating Voltage Range 85% to 110%.
Current Up to 30A or device rating.
Frequency 60 Hz.
Trip Level 4-6 mA.
Phase Single.
Response Time .025 sec. Max.
Dielectric Withstand 1500 VRMS across contact, 4000 VRMS between conductors and enclosure.
Surge Withstand 6000V impulse, 0.5 microseconds rise time 100kHz ringing frequency with
40% decay per cycle.
Let Go Line Voltage 60% of rated.
Grounded Neutral Detection 6 Ohms or less.
Power Up Manual or automatic reset.
Environmental Ratings
Housing Rating UL Type 4X.
Construction Industrial grade design.
Type Class A GFCI.
Operating Temperature -35°C to 66°C, -30°F to 150°F.
Leakage Current @ 93% Humidity Zero.
Features
Life (Endurance) 10,000 cycles (6000 with load and 4000 without load).
Open neutral protection Trips upon loss of neutral.
Grounded Neutral Protection Trips if ground and neutral touch at load side.
Power On Indicator Green light on.
Power Off Indicator Red blinking light plus optional audible alarm.
Wiring Application 3 Wire Single Phase (Hot, Neutral and Ground),
4 Wire Single Phase (Line 1,Line 2, Neutral and Ground).
Switch Interface Double Insulated.
Latching Mechanism Electromagnetic.
Physical Specifications
Wire Leads #10 AWG, 24" long.
Unit Color Gray with black cover.
Label Color on Portable Automatic reset: yellow background with black lettering.
and Hard Wired Units Manual reset: black background with yellow lettering.
Weight 1.40 lbs.
Related Code
Conned Space OSHA 29 CFR 1926.404 (b) (1) (ii)
OSHA 29 CFR 1926.405 (a) (2) (ii) (G)
Construction Sites NEC 590.6
Commercial Garages N EC 511.12
Fountains NEC 680.5B
Spas and Hot Tubs NEC 680.40
Marinas NEC 555.3
Applications
Power Generators Agricultural Equipment Production Assembly Equipment
Submersible Pumps Cement Cutting Equipment Spa and Hot Tubs
Tex tile Food Processing Vending Equipment
Dimensional Drawing
3.37"
(85.6)
4.80"
(121.9)
2.82"
(12.9)
.20 x 4
¾" N.P.T.
Side View
2.64"
(67.1)
5.75"
(146.0)
24.00"
(609.6)
Dimensions in Inches (mm)
GFP1311
GFPIL30250LKM
www.hubbell-wiring.comK-18 Wiring Device-Kellems
®
Circuit Guard® Portable 30A GFCI - UL Type 4X Rated
Description Cord Length Voltage Manual Set Automatic Set
Portable, manual set and
automatic set GFCIs.
2' (60.9 cm) 120V AC GFP1301 GFP1311
6' (182.9 cm) 120V AC GFP1305 GFP1315
25' (762.0 cm) 120V AC GFP1302 GFP1312
50' (1524.0 cm) 120V AC GFP1303 GFP1313
2' (60.9 cm) 240V AC GFP2301 GFP2311
25' (762.0 cm) 240V AC GFP2302 GFP2312
6' (182.9 cm) 120/240V AC GFP3305 GFP3315
6' (182.9 cm) 3Ø 250V AC GFP5305 GFP5315
6' (182.9 cm) 3Ø 120/208V AC GFP4305 GFP4315
Note: All units above are stock items.
Circuit Guard® 30A GFCI In Line GFCI – Locking
Description Cord Length Voltage Manual Set Automatic Set
L5-30 locking. 2' (60.9 cm) 120V AC GFPIL30125LKM GFPIL30125LKA
L6-30 locking. 2' (60.9 cm) 250V AC GFPIL30250LKM GFPIL30250LKA
Plug and Connector Selector Chart (partial listing)
The chart below is a list of possible Hubbell plug and connector body products that can be used with the Hubbell
Portable GFCIs.
Family Style Amps Voltage Hubbell Catalog Number
Insulgrip® Straight Blade 15 120V AC HBL5266C & HBL5269C
Insulgrip® Twist-Lock® 30 240V AC HBL2621 & HBL2623
Watertight Safety-Shroud® Twist-Lock® 30 240V AC HBL2621SW & HBL2623SW
IEC Pin & Sleeve Watertight Pin & Sleeve 30 240V AC HBL330P6W & HBL330C6W
Insulgrip® Pin & Sleeve Insulgrip® Pin & Sleeve 30 240V AC HBL330PS2W & HBL330CS2W
Hubbellock® Hubbellock® 20 120V AC HBL23035B & HBL23032B
Ground Fault Products
Portable 30 Ampere GFCI - NEMA 4X
Features
Life (Endurance) 10,000 cycles (6000 with load and 4000 without load).
Open Neutral Protection Trips upon loss of neutral.
Grounded Neutral Protection Trips if ground and neutral touch at load side.
Power On Indicator Green light on.
Power Off Indicator Red blinking light plus optional audible alarm.
Wiring Application 3 Wire Single Phase (Hot, Neutral and Ground).
4 Wire Single Phase (Line 1, Line 2, Neutral and Ground).
Switch interface Double Insulated.
Latching Mechanism Electromagnetic.
Physical Specifications
Cord Type 2-50', 10/3 SJGOOW. 100', 8/3 SEOW.
Unit Color Gray with black cover.
Label Color on Portable Automatic reset: Yellow background with black
and Hard Wired Units lettering. Manual reset: Black background
with yellow lettering.
Weight 2 ft. 1.8 lbs., 6 ft. 2.7 lbs., 25 ft. 6.8 lbs.,
50 ft. 12.4 lbs.,100 ft. 23.3 lbs.
Specifications
Electrical Ratings
Rated Voltage 120V AC, 240V AC, 120/240V AC,
3Ø 250V AC, 3Ø 120/208V AC.
Operating Voltage Range 85% to 110%.
Current Up to 30A or device rating.
Frequency 60 Hz.
Trip Level 4-6 mA.
Response Time 25 mS Max.
Dielectric Withstand 1500 VRMS across contact, 4000 VRMS
between conductors and enclosure.
Surge Withstand 6000V impulse, 0.5 microseconds rise time
100kHz ringing frequency with 40% decay
per cycle.
Let Go Line Voltage 60% of rated.
Power Up Manual or Automatic reset.
Environmental Ratings
Housing Rating UL Type 4X.
Construction Industrial grade design.
Type Meets UL943 Class A GFCI.
Operating Temperature -35°C to 66°C, -30°F to 150°F.
Leakage Current @ 93% Humidity Zero.
Applications
Pressure Washers Portable Electric Heaters Portable Power Tools
De-icing Equipment Material Dryers Submersible Pumps
Pipeline Heaters Automotive Garages Outdoor Signage
Related Code
Conned Space OSHA 29 CFR 1926.404 (b) (1) (ii)
OSHA 29 CFR 1926.405 (a) (2) (ii) (G)
Construction Sites NEC 590.6
Commercial Garages NEC 511.12
Outdoor Signs NEC 60 0.10
Spas and Hot Tubs NEC 680.40
Boat Yards NEC 555.3
Dimensional Drawing
4.80"
(121.9)
3.37"
(85.6)
Dimensions in Inches (mm)

Navigation menu