1
Subject to change without notice PH (763) 422-2661 • FX (763) 422-2588 • homanonline.com © 2010 Pentair Technical Products
Networking: Wall-Mount Cabinets
ACCESSPLUS® II Double-Hinge
Spec-00534 E
Spec-00534
E
PH (763) 422-2661
FX (763) 422-2588
Networking
Wall-Mount Ca binets
ACCESSPLUS® II Dou ble-Hin ge
ACCESSPLUS® II Double-Hinge, Type 1
Industry Standards
UL 508A; Type 1; File No. E61997
cUL Listed per CSA C22.2 No. 182.4; File No. E230874
EIA 310-D
NEMA/EEMAC Type 1
EIC 60529 IP20
Per BICSI TDMM Tenth edition, Chapter 7,
Telecommunication Enclosures (TE)
Application
ACCESSPLUS® II Cabinets provide security, equipment access, cooling
and support for network and other 19-in. rack-mount equipment. The
cabinet has three components: front door, center section and wall
section.
Features
Double-hinged for easy equipment access; center section provides
19-in. rack mounting per EIA universal spacing and is accessed
through the front door or swing the center section away from the
wall section for rear access
Round corners; no sharp edges
Front door has either a solid steel or hardened, tinted safety-glass
window door for superior scratch resistance
Center section easily removed from rear section; tool-less one-
person installation possible
Self-grounding, plated steel rack angles fully adjustable within
center section
Wall section provides cable entry and cable management with
knockouts or gland plates
Gland plate model provides easy retrot and fast installation and
allows for pre-terminated cables or pre-wired patch panels; no
need to re-terminate and test
Self-locking center-to-wall section latches in two locations
Front access to all latches (no exposed side latches); cabinet can be
installed tightly in corners
Vented sides provide cross ow ventilation to improve heat
dissipation
Vertical cable manager included in 28-in.-wide models
A full line of accessories is available
Specications
Front Door (window or solid steel)
Composite frame (injection molded top and bottom with extruded
composite sides)
140-degree opening door
Field-reversible (left or right) hinge
Quarter-turn key lock, two keys included
Window door is scratch-resistant 1/4-in. tinted safety glass
Solid door has 16 gauge steel insert with matching black nish
Center Section
Welded 14 gauge steel
Solid top of center sections provides protection against falling
debris
Ventilated sides (to which fans can be added)
Self-latching closure connects center section to wall section
Self-alignment ramp supports center section to wall section
Heavy duty center-to-rear section hinge with quick-release self-
retained hinge pin eases wall installation
Rack-Mounting Angles
12 gauge, plated steel
EIA universal spaced 19-in. rack-mounting holes
RU marked from bottom to top
Tapped 10-32 holes, 20 mounting screws included
Rear Wall Section
Welded 14 gauge steel
Radius corners; no sharp edges
Available with knockouts or gland plates
Raised pads for accessory mounting
Cable tie-down points for cable management
Keyhole mounting holes allow wall section to be mounted over
fasteners and eases installation
Three cable-entry grommets
Finish
Pretreated steel coated with RAL 9005 black light-textured, low-gloss
polyester powder paint. Other nishes available—contact Homan
Customer Service.
Bulletin: DWDH1
2Subject to change without notice PH (763) 422-2661 • FX (763) 422-2588 • homanonline.com © 2010 Pentair Technical Products
Networking: Wall-Mount Cabinets
ACCESSPLUS® II Double-Hinge
Spec-00534 E
Standard Product Window Door
Catalog Number AxBxC in. AxBxC mm Rack Units Additional Rack Angles (S=Square Hole) (T=Tapped Hole)
EWMW242418 23.60 x 23.62 x 18.20 600 x 600 x 462 12 EWMR24T or EWMR24S
EWMW362418 36.02 x 23.62 x 18.20 915 x 600 x 462 19 EWMR36T or EWMR36S
EWMW482418 48.03 x 23.62 x 18.20 1220 x 600 x 462 26 EWMR48T or EWMR48S
EWMW602418 60.04 x 23.62 x 18.20 1525 x 600 x 462 32 EWMR60T or EWMR60S
EWMW722418 72.05 x 23.62 x 18.20 1830 x 600 x 462 39 EWMR72T or EWMR72S
EWMW242425 23.62 x 23.62 x 25.09 600 x 600 x 637 12 EWMR24T or EWMR24S
EWMW362425 36.02 x 23.62 x 25.09 915 x 600 x 637 19 EWMR36T or EWMR36S
EWMW482425 48.03 x 23.62 x 25.09 1220 x 600 x 637 26 EWMR48T or EWMR48S
EWMW602425 60.04 x 23.62 x 25.09 1525 x 600 x 637 32 EWMR60T or EWMR60S
EWMW722425 72.05 x 23.62 x 25.09 1830 x 600 x 637 39 EWMR72T or EWMR72S
EWMW242430 23.62 x 23.62 x 30.01 600 x 600 x 762 12 EWMR24T or EWMR24S
EWMW362430 36.02 x 23.62 x 30.01 915 x 600 x 762 19 EWMR36T or EWMR36S
EWMW482430 48.03 x 23.62 x 30.01 1220 x 600 x 762 26 EWMR48T or EWMR48S
B dimension does not include wall-to-center section hinge.
3
Subject to change without notice PH (763) 422-2661 • FX (763) 422-2588 • homanonline.com © 2010 Pentair Technical Products
Networking: Wall-Mount Cabinets
ACCESSPLUS® II Double-Hinge
Spec-00534 E
Standard Product Solid Door
Catalog Number AxBxC in. AxBxC mm Rack Units Additional Rack Angles (S=SquareHole) (T=Tapped Hole)
EWMS242418 23.62 x 23.62 x 18.20 600 x 600 x 462 12 EWMR24T or EWMR24S
EWMS362418 36.02 x 23.62 x 18.20 915 x 600 x 462 19 EWMR36T or EWMR36S
EWMS482418 48.03 x 23.62 x 18.20 1220 x 600 x 462 26 EWMR48T or EWMR48S
EWMS242425 23.62 x 23.62 x 25.09 600 x 600 x 637 12 EWMR24T or EWMR24S
EWMS362425 36.02 x 23.62 x 25.09 915 x 600 x 637 19 EWMR36T or EWMR36S
EWMS482425 48.03 x 23.62 x 25.09 1220 x 600 x 637 26 EWMR48T or EWMR48S
B dimension does not include wall-to-center section hinge.
Standard Product Window Door with Cable Manager
Catalog Number AxBxC in. AxBxC mm Rack Units Additional Rack Angles (S=Square Hole) (T=Tapped Hole) Vertical Cable Mgr. Catalog Number a
EWMW242825 23.62 x 27.56 x 25.09 600 x 700 x 637 12 EWMR24T or EWMR24S EWMC24
EWMW362825 36.02 x 27.56 x 25.09 915 x 700 x 637 19 EWMR36T or EWMR36S EWMC36
EWMW482825 48.03 x 27.56 x 25.09 1220 x 700 x 637 26 EWMR48T or EWMR48S EWMC48
B dimension does not include wall-to-center section hinge.
a For additional rack angles, also order vertical cable manager.
4Subject to change without notice PH (763) 422-2661 • FX (763) 422-2588 • homanonline.com © 2010 Pentair Technical Products
Networking: Wall-Mount Cabinets
ACCESSPLUS® II Double-Hinge
Spec-00534 E
Standard Product Window Door with Gland Plate
Catalog Number AxBxC in. AxBxC mm Rack Units Additional Rack Angles (S=Square Hole) (T=Tapped Hole)
EWMWG242418 23.62 x 23.62 x 18.20 600 x 600 x 462 12 EWMR24T or EWMR24S
EWMWG362418 36.02 x 23.62 x 18.20 915 x 600 x 462 19 EWMR36T or EWMR36S
EWMWG482418 48.03 x 23.62 x 18.20 1220 x 600 x 462 26 EWMR48T or EWMR48S
EWMWG242425 23.62 x 23.62 x 25.09 600 x 600 x 637 12 EWMR24T or EWMR24S
EWMWG362425 36.02 x 23.62 x 25.09 915 x 600 x 637 19 EWMR36T or EWMR36S
EWMWG482425 48.03 x 23.62 x 25.09 1220 x 600 x 637 26 EWMR48T or EWMR48S
B dimension does not include wall-to-center section hinge.
Load Rating
Height Load Capacity
24 in. 250 lbs.
36 in. 300 lbs.
48 in. 350 lbs.
60 in. 400 lbs.
72 in. 500 lbs.
5
Subject to change without notice PH (763) 422-2661 • FX (763) 422-2588 • homanonline.com © 2010 Pentair Technical Products
Networking: Wall-Mount Cabinets
ACCESSPLUS® II Double-Hinge
Spec-00534 E
Vertical Cable Managers for 28-in.-Wide
Cabinet
Use ACCESSPLUS Cable Managers when ordering additional rack
angles for 28-in.-wide cabinet.
Bulletin: DWDH1
Catalog Number Description Fits Cabinet
EWMC24 ACCESSPLUS Vertical Cable Manager 24.00 in. A = 24.00; B = 28.00
EWMC36 ACCESSPLUS Vertical Cable Manager 36.00 in. A = 36.00; B = 28.00
EWMC48 ACCESSPLUS Vertical Cable Manager 48.00 in. A = 48.00; B = 28.00
Vertical Cable Manager Capacity
Number of cables at 60 percent lled
Cross Section (Area) 5e (0.22 in. dia.) 6 (0.28 in. dia.) 6A (0.35 in. dia.)
24.5 in. 2 380 300 208
Rack Angles Bulletin: DWDH1
Catalog Number Description Rack Units Fits Cabinet
EWMR24T Fits 24-in. tapped 12 A = 24.00
EWMR36T Fits 36-in. tapped 19 A = 36.00
EWMR48T Fits 48-in. tapped 26 A = 48.00
EWMR60T Fits 60-in. tapped 32 A = 60.00
EWMR72T Fits 72-in. tapped 39 A = 72.00
EWMR24S Fits 24-in. square 12 A = 24.00
EWMR36S Fits 36-in. square 19 A = 36.00
EWMR48S Fits 48-in. square 26 A = 48.00
EWMR60S Fits 60-in. square 32 A = 60.00
EWMR72S Fits 72-in. square 39 A = 72.00
Fan Kits Bulletin: DWDH1
Catalog Number Description Fits Cabinet
EWMF1 4-in. fan with plug and blocking plates,
115 VAC, 100 CFM small
Fits all C = 18.00
EWMF2 4-in. fan with plug and blocking plates,
115 VAC, 100 CFM, large
Fits all C = 25.00 or 30.00
6Subject to change without notice PH (763) 422-2661 • FX (763) 422-2588 • homanonline.com © 2010 Pentair Technical Products
Networking: Wall-Mount Cabinets
ACCESSPLUS® II Double-Hinge
Spec-00534 E
DataCom Wall-Mount Cabinet with Gland Plate Application
1
Networking: Wall-Mount Cabinets
ACCESSPLUS® II Double-Hinged
Spec-00554 C
Subject to change without notice PH 763 422 2661 • FX 763 422 2588 • homanonline.com © 2009 Homan Enclosures Inc.
DataCom Wall-Mount Cabinet with Gland Plate Application
This cabinet oers signicant advantages in retrot applications. The gland plate is mounted at the top and the bottom to accommodate
cable runs from above, below or both. The gland plate casing can be removed while patch panels and associated wiring are brought to the
cabinet.
2. Install the cable gland plate onto the wall section.
4. Install the center section, then mount patch panels on rack
angles.
5. Close and lock the door.
1. Once the wall section is installed on the wall, lay in the
patch panel.
3. Use wire ties or cable wraps to secure the cable to the
cabinet.
Spec-00554.indd 1 10/5/2009 2:02:19 PM