109532 Catalog

2014-07-30

: Pdf 109532-Catalog 109532-Catalog 782274 Batch6 unilog

Open the PDF directly: View PDF PDF.
Page Count: 298

Download109532-Catalog
Open PDF In BrowserView PDF
2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0661-6 Name: L-661

100:
DATE: JAN 19 2006

Time: 5:41:45 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Industrial
Lighting
Section L

661

STIBOINFO((CRH:66008com:L:661))
CHI NT R OL

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0662-13 Name: L-662

L

DATE: JAN 19 2006

Time: 5:41:47 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Industrial Lighting
Table of Contents

Section L of the Cooper Crouse-Hinds
Catalog contains information on industrial
lighting.
Product details on individual luminaires are
given in eleven separate sections, as noted
below. In addition, a complete section (8L) is
devoted to luminaire hangers and
accessories.

Considerations for Selection
Preceding the eleven product sections is a
Selector Guide. Included in this section is
information on:
ɀ a selection of the appropriate light source
for a given application
ɀ a Quick Selector Guide of the luminaires
that are designed and approved to meet the
various environmental requirements of the
National Electric Code
ɀ determining the proper size (i.e., wattage)
and number of units to achieve the desired
light levels in a given application
ɀ methods to follow in making a luminaire
layout. Cat. Nos. are shown, in many cases,
for complete assemblies including mounting,
reflector, globe, and guard, as well as
individual components. In these cases,
ordering can be done by component or by
complete assembly. Photometric and other
technical data is included in each section for
the luminaires it contains.
Information relating to product families in the
Lighting Section is shown as follows:

Section 3L
High Intensity Discharge
(H.I.D.) Lighting—
Enclosed and Gasketed
(for use in hazardous [classified]
locations, non-hazardous
locations, and marine locations)
Indoor and outdoor vaportight luminaires for
use in applications where dirt, moisture, and
corrosion problems exist. Included are units
with integral ballasts.
DMV Champ® Series
LMV Champ® Series
VMV Champ® Series
N2MV Champ® Series

Section 4L
High Intensity Discharge
(H.I.D.) Lighting
Indoor and outdoor luminaires and
accessories. Included are luminaires with
integral ballasts.
HazardȿGard® Series
LoȿPro HazardȿGard® Series

A variety of portable luminaires for hazardous
and non-hazardous applications.
VS
EVH
RCDER
EVP

Section 5L
Luminaires with Induction
Lighting System

(for use in non-hazardous areas;
some luminaires have specific
hazardous [classified] locations
suitability.)

Section 6L
Fluorescent Lighting

(for use in hazardous [classified]
locations)
Indoor and outdoor luminaires and
accessories
EV Series
EVI Series

DMVIG, VMVIG

(for use in hazardous [classified]
locations and non-hazardous
locations)
Indoor and outdoor fluorescent luminaires
and accessories for application in all classes
of hazardous and non-hazardous locations.
For hazardous
For non-hazardous
locations
locations
CPMVF
NFL
EVF, EVFDR
VF Vaporgard Series
FVN, FVS
EVFT, DMVF
N2MVF, EVLPF
VF, ELLK, NLLK
eLLB20

Section 7L
Floodlights
(for use in hazardous [classified]
locations and non-hazardous
locations)
CPMV Champ-Pak TM Wall Pack
EVMA-S812 HazardGard® Series
FMV Champ® Series
F2MV, FMV1000
FZD
RCDE
SSFMV Voyager nR TM

662

STIBOINFO((CRH:66008com:L:662))
CH0 0 0 L - 0

A variety of luminaire hangers for use with the
luminaires listed. Information on mounting
accessories required and typical luminaire
weights also included.
For hazardous
For non-hazardous
locations
locations
EAHC, EFHC
AL
EC
AHG
EFH
ARB
GUA, GUF
FHM
UNR
UNE, UNH, UNHC
CPS
UNJ
UNJC

Section 9L
Portable Lighting

(for use in hazardous [classified]
locations, non-hazardous
locations, and marine locations)

Section 2L
Incandescent Lighting

(for use in hazardous [classified]
locations and non-hazardous
locations)

(for use in hazardous [classified]
locations)

Section 1L
Incandescent Lighting—
Enclosed and Gasketed

Indoor and outdoor vaportight luminaires and
accessories for use in industrial applications
where dirt, moisture, and corrosion problems
exist.
V160
NDA CorroȿGard® Series
V Series
Vaporgard TM Series

Section 8L
Luminaire Hangers and
Accessories

US: 1-866-764-5454

CAN: 1-800-265-0502

Section 10L
Emergency Lighting
(for use in hazardous [classified]
locations)ɍ
Emergency lighting for use in power outage
situations. Also, exit signs and strobe warning
lights.
CPMVFB
N2LPS Light-Pak TM Series
EXL – exit sign
DMVFB
N2MVFB
ELPS Light-Pak TM Series
EVLPFB

Section 11L
Beacons and Strobes
Indoor and outdoor luminaires for use in
applications where visual signaling is a
requirement.
For hazardous
locations
EX Beacons and Strobes
VF Beacons
VDAS Strobes

Section 12L
Specialty Lighting
Luminaires for use in applications where
conventional lighting is not acceptable due to
size and/or location, such as tank,
instrument, and gauge applications.
For hazardous
For non-hazardous
locations
locations
EV – tank lights
V Observation
EVTL
ELG – gauge light

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0663-9 Name: L-663

100:
DATE: JAN 19 2006

Time: 5:41:47 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Industrial Lighting Products

L

Quick Reference Chart

LIGHT SOURCE

WallPacks & Luminaire
Floodlights Hangers

ɀ Exit Signs
ɀ Emergency
Lighting
ɀ ‘‘Steady On’’
Beacons
ɀ Strobes

ɀ Pulse Start
Metal Halide
ɀ Metal Halide
ɀ High Pressure
Sodium
ɀ Mercury Vapor
ɀ Incandescent

Application
Environment

Incandescent

H.I.D.
ɀ Pulse Start
Metal Halide
ɀ Metal Halide
ɀ High Pressure
Sodium
ɀ Mercury Vapor

Fluorescent
ɀ Linear
ɀ Long Twin
Tube
ɀ Compact

General Industrial

Section 1L
Vaporgard TM, V
Series, NDA
Section 12L
V160 Tank light

Section 3L
LMV, DMV, VMV,
N2MV Champ®
Section 5L
Champ Induction

Section 6L
VF Series, NFL,
FVN, FVS
DMVF, N2MVF

Section 10L
N2LPS Light-Pak TM,
DMVFB, N2MVFB
Section 11L
VF ‘‘SO’’ Beacon
VDAS Strobe

Section 7L
F2MV, FMV,
FMV1000

Section 8L
AL, UNJ, FHM,
ARB, UNE, UNH,
CHS

Wet Locations

Section 1L
Vaporgard TM , V
series, NDA

Section 3L
LMV, DMV, VMV,
N2MV Champ®
Section 5L
Champ Induction

Section 6L
VF Series, NFL,
FVN, FVS, DMVF,
N2MVF

Section 10L
DMVFB, N2MVFB,
N2LPS Light-Pak TM,
Section 11L
VF ‘‘SO’’ Beacon
VDAS Strobe

Section 7L
F2MV, FMV,
FMV1000

Section 8L
AHG, ARB–21 series

Marine Locations
or 4X

Section 1L
NDA

Section 3L
LMV, DMV, VMV,
N2MV Champ®
Section 4L
EVLP Lo-Pro
EVM Hazard-Gard

Section 6L
NFL, FVS, DMVF,
N2MVF, CPMVF
EVFDR,
EVFT Illuminator TM

Section 10L
DMVFB, N2MVFB,
Section 11L
VDAS Strobe

Section 7L
CPMV, F2MV,
FMV, FMV1000

Corrosive

Section 1L
Vaporgard TM, NDA

Section 3L
LMV, DMV, VMV,
N2MV Champ®
Section 5L
Champ Induction

Section 6L
NFL, N2MVF, FVS,
VF Series, DMVF,
CPMVF

Section 10L
DMVF-EXD exit,
N2MV-EXD exit,
N2LPS Light-Pak TM,
N2MVFB, DMVFB
Section 11L
VF ‘‘SO’’ Beacon
VDAS Strobe

Section 7L
CPMV, F2MV,
FMV, FMV1000

Section 8L
EFHC-S752
ECHF-S758
ECF-S516

Class I, Div. 1 or
Zone 1

Section 2L
EV
Section 12L
EVTL, EVA160,
EVO, ELG

Section 4L
EVLP Lo-Pro
EVM Hazard-Gard

Section 6L
EVF, EVFDR,
EVFT Illuminator®,
EVLPF, eLLK

Section 10L
EXL exit,
EVLPF-EXD exit,
ELPS Light-Pak TM
EVLPFB
Section 11L
EV ‘‘SO’’ Beacon
EVAS Strobe

Section 7L
FZD, EVM-S812,
RCDE

Section 8L
EAHC, EFHC,
ECHF, GUA, GUFX,
EFHX, CPS, UNR

Class I, Div. 2 and
Zone 2

Section 1L
Vaporgard TM,
NDA

Section 3L
LMV, DMV, VMV,
N2MV Champ®
Section 5L
Champ Induction

Section 6L
VF Series, NFL,
nLLK, eLLK, FVN,
FVS, CPMVF,
DMVF, N2MVF

Section 10L
DMVF-EXD exit,
N2LPS Light-Pak TM,
DMVFB, N2MVFB
Section 11L
VF ‘‘SO’’ Beacon
VDAS Strobe

Section 7L
CPMV, F2MV,
FMV, FMV1000
FZD

Section 8L
AL, AHG, UNJ,
UNJC, ARB, UNE,
UNH, COUP

Section 3L
LMV, DMV, VMV,
N2MV Champ®
Section 5L
Champ Induction

Section 6L
CPMVF, DMVF,
N2MVF

Section 10L
DMVFB, N2MVFB

Section 7L
CPMV, F2MV,
FMV

Section 8L
AL, AHG, UNH,
UNJC, ARB, UNE,
UNH, COUP

Section 3L
LMV, DMV, VMV,
N2NV Champ®
Section 4L
EVLP Lo-Pro
EVM Hazard-Gard
Section 5L
Champ Induction

Section 6L
FVN, nLLK, eLLK,
FVS, DMVF,
N2MVF
EVF, EVFDR,
EVFT, EVLP

Section 10L
EXL,
N2LPS Light-Pak TM,
DMVFB, N2MVFB
Section 11L
VF ‘‘SO’’ Beacon
VDAS Strobe
EVAS Strobe

Section 7L
CPMV

Section 8L
ECHF, GUA,
GUF,
GUJ. EAHC, EFHC,
AHG (Class II, Div 2)

Section 4L
EVP

Section 6L
EVF, EVFT

Section 9L
EVP

Section 9L
EVH

US: 1-866-764-5454

CAN: 1-800-265-0502

Restricted Breathing
ɀ Class I, Div 2
and Zone 2
ɀ Certified IEC
Zone 2
Class II
Class III
Simultaneous
Presence

Section 2L
EV
Section 12L
EVTL, EVO

Paint Spray
Portables

STIBOINFO((CRH:66008com:L:663))
CH0 0 0 L - 1

Emergency
& Warning

Section 9L
VS, EVH,
RCDER

Copyright© 2006 Cooper Crouse-Hinds

663

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0664-3 Name: L-664

L

100:
DATE: JAN 19 2006

Time: 5:41:48 PM Operator: JB

COLOR: CMYK

TCP: 15001

Industrial Lighting Products

New ideas in industrial lighting, translated
into modern equipment design, backed
technically by a nationwide sales force,
available worldwide through knowledgeable
electrical distributors – these are some of the
reasons you’ll be light-years ahead when you
look to Cooper Crouse-Hinds for industrial
lighting products.
This Lighting Selector Guide will help you
solve many of your lighting problems. For
additional assistance on complex projects,
call your Cooper Crouse-Hinds
representative or distributor. They can
provide detailed lighting layouts and
recommendations using the most advanced
computer and application engineering
facilities and techniques.

Lighting Selector Guide
Below is a simple five-step procedure to help
you select the right equipment for a specific
job. Typical examples – with illustrations,
easy-to-read charts, and layouts – are
included to ensure correct results.
The five steps are:
1.) Determine Area
Lighting Needs
and Operational
Factors
Page 665

When known,
proceed to Step 2

2.) Select
Type of Lamp
Page 666

When known,
proceed to Step 3

3.) Select
Type of
Luminaire
Page 668

When known,
proceed to Step 4

4.) Calculate
Number of
Luminaires
Required
Page 683

When several light
sources or systems
seem suitable,
determine most
economical one

With Luxicon TM you’ll be able to make
‘light’ work of analyzing the performance
of Cooper Crouse-Hinds broad line of
industrial luminaires.
From exterior/interior layouts to economic
performance data, you’ll be able to access
and evaluate information needed to design
and specify the most efficient and effective
lighting system possible.
Luxicon TM offers:
ɀ Online tutorial
ɀ Color output, either text or graphics
ɀ Exterior/interior layouts in one program
ɀ Daylight lighting analysis
ɀ Importing/exporting of any IES file
ɀ Importing/exporting of any .DXF CAD file
ɀ Detailed architectural feature calculations
ɀ Entire Cooper Crouse-Hinds and Cooper
Lighting line search
ɀ Economic performance/analysis
calculations
ɀ Database of customers and their projects
ɀ Professional output including summary
reports, luminaire schedules, calculation
results and renderings on multiple pages
ɀ Luminaire editing capabilities
ɀ Allowances of varying ambient temperature
levels

5.) Determine
Placement of
Luminaires and
Make Layout
Page 688

664

STIBOINFO((CRH:66008com:L:664))
CH0 0 0 L - 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0665-2 Name: L-665

DATE: JAN 19 2006

Time: 5:41:49 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Industrial Lighting Products

L

1

Determine Area Lighting Needs and Operational Factors
The selection of the proper luminaire/lamp
combination and the determination of the
number of luminaires required is a function of
the desired quantity and quality of light
required, together with consideration of any
special factors arising from the nature of the
work operation.
Several aspects of this selection process are
discussed below. The conditions will vary
from job to job. It is important to consider
these conditions if the lighting system is to
yield optimum results.
A) Determine Illumination Quantity
Required
The Illuminating Engineering Society in the
current IES Lighting Handbook gives a
comprehensive listing of footcandle levels
recommended for all types of Industrial
Lighting. A condensed version of this listing is
given in Table I and is presented according to
the types of visual tasks encountered.

B) Determine Illumination Quality Required
Quality of illumination pertains to the
distribution of brightness in the visual
environment. Care must be taken to avoid
discomforting glare within the normal visual
field.
Luminaires normally selected for lower
mounting should be designed to limit
brightness below the 45° zone.
C) National Electric Code Compliance
The National Electric Code delineates some
areas as hazardous, depending on materials
or atmosphere within an area. The choice of
luminaire and lamp is therefore somewhat
restricted if the area is classified as
hazardous.
In hazardous areas, luminaire design and
operating temperature of both luminaire and
lamp must meet strict limitations. These
limitations are detailed under Step 3 of this
selection guide.

Table 1 / Recommended Levels of Illuminance
Illuminance
Category

Footcandles†

Difficult assembly and
inspection, color coding, paper
manufacturing (Inspection and
Rewinder) finishing operations.

F

100 to 200

Moderate

Moderately difficult assembly
and inspection, checking and
sorting, service garage repair
areas, medium bench work,
instrument panel (vertical
illumination).

E

50 to 100

Casual

Simple assembly, rough bench
work, grinding, simple
inspection, wrapping, packing
and labeling, control house
general lighting.

D

20 to 50

Easy

Rough active storage,
washrooms, dry lumber
warehouse, compressor
houses.

C

10 to 20

Limited

Inactive storage, stairway

B

5 to 10

Seeing Task

Typical Type of Work

Difficult

NOTE: For other industrial footcandle levels such as petrochemical, refer to the Illuminating
Engineering Society’s Lighting Handbook (Application Volume) for more information.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:L:665))
CH0 0 0 L - 3

CAN: 1-800-265-0502

If the area is non-hazardous in nature, the
selection of the proper luminaire and lamp is
less restrictive and should be based on
general operational and environmental
conditions.
D) Maintenance Considerations
In order to insure optimum performance of
the lighting system at a reasonable cost,
some of the following related factors must be
introduced into the selection process:
ɀ Atmospheric Conditions: Luminaires for use
in extremely wet locations should be
enclosed and gasketed.
Luminaires for use in extremely dirty
locations should provide a minimum of light
depreciation under the anticipated
maintenance schedule (i.e., reflector with
open top and bottom should be used where
maintenance is infrequent). Luminaires for
use in extremely corrosive atmospheres
should have protection for the optical system
and have finishes to withstand the particular
corrosive agent (i.e., epoxy power finish;
enclosed Alzak reflector; Krydon TM fiberglass
reinforced polyester reflector).
ɀ Accessibility: Since it may be necessary to
locate luminaires in inaccessible areas, the
luminaire and lamp selected should minimize
need for maintenance and maximize ease of
maintenance when required (i.e., high bay
open reflector with mercury lamp).
ɀ Area Usage: The selection of the proper
lamp/luminaire combination will depend
greatly on the required burning hours per
year. The anticipated usage should be a
major factor in lamp selection.

† Values recommended are average maintained footcandles
at 30⍯ above floor (work plane).

Copyright© 2006 Cooper Crouse-Hinds

665

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0666-2 Name: L-666

L

100:
DATE: JAN 19 2006

Time: 5:41:49 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Industrial Lighting Products

2

Select Type of Lamp
After identification of the factors discussed in
Step 1, the following guide can be used in
selecting the proper lamp:
A) Illumination Level
High (30FC or more): high intensity
discharge (H.I.D.) lamps are generally the
most economic choice.
ɀ Exception: where luminaires must be
placed within an operator’s normal visual
span, a low brightness light source such as
fluorescent should be used.
Low (less than 30FC): all light sources can be
considered. Selection of best lamp is usually
based on other factors.
ɀ Exception: at medium to high mounting,
high intensity discharge is generally best.
B) National Electrical Code®
Hazardous locations – all light sources can
be considered.
ɀ Exception: Article 500 of the National
Electrical Code classifies the various
categories of hazardous locations and
provides general rules for the application of
luminaires in these areas. (See Step 3 of
Selection Guide.)
ɀ Exception: where process must be shut
down for relamping, high intensity discharge
is best due to long lamp life. Non-hazardous
locations – all light sources.

C) Accessibility
High intensity discharge lamps should be
used where luminaires are relatively
inaccessible because of long life and the
need for infrequent relamping.
D) Area Usage (Burning Hours)
At more than 2,000 burning hours per year,
high intensity discharge and fluorescent
lamps generally yield the lowest system cost.
At less than 2,000 hours per year,
incandescent may be the best system
depending on the size of the area, mounting
height and illumination level required.
E) Other Considerations
ɀ Energy cost: where energy cost is high,
high intensity discharge lamps generally
prove most economical. H.I.D. lamps
produce more lumens per watt of electricity
than other lamp types.
ɀ Safety: due to warmup and restart
characteristics of high intensity discharge
lamps, auxiliary or emergency lighting should
be used in critical areas.

Continued

666

STIBOINFO((CRH:66008com:L:666))
CH0 0 0 L - 4

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0667-3 Name: L-667

100:
DATE: JAN 19 2006

Time: 5:41:50 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Industrial Lighting Products

2

L

(continued)

Select Type of Lamp
The following table of lamp characteristics
provides guidelines for choosing the best
lamp. If the decision is not obvious, contact
your Cooper Crouse-Hinds representative for
a computer analysis of the option desired.

Table II/Lamp Characteristics
Lamp

Advantages

Disadvantages

1.

Induction

Exceptionally long life – 100,000 hours.
Instant illumination upon start-up or warm
restart. Crisp, white light >80 color rending
index. Low operating cost.

Initial cost is higher than HID type luminaires.

2.

High Pressure Sodium

Good beam control. Long lamp life (24,000
hrs). Highest lamp output (lumens per watt).
Low operating cost. Shortest restart time of
H.I.D. lamps (instant with optional instant
restrike).

High initial cost. Requires warmup period.

3.

Metal Halide
Pulse Start

Improved lamp life (15,000- 30,000 hrs).
Increased lumen output over standard
metal halide (25 to 50%). Better lumen
maintenance (80%). Superior cold starting
-40°C. Improved color stability. Color shift
reduced by two-thirds. Improved lamp-tolamp color consistency. Warm up time 2
minutes. Restrike time 3-4 minutes.

High initial cost. Requires warmup period. Does
not restart immediately after power outage.

4.

Metal Halide

Moderately long lamp life (7500 + hrs).
High light output (lumens per watt). Makes
colors look close to natural. Low operating
cost.

High initial cost. Requires warmup period. Does
not restart immediately after power outage.

5.

Mercury

Long lamp life (24,000 hrs). High light
output per watt. Low operating cost.

High initial cost. Requires warmup period. Does
not restart immediately after power outage.

6.

Fluorescent

Long lamp life (7500-24,000 hrs). High light
output per watt. Low operating cost. Low
brightness. Cool operation.

High initial cost. Poor light control. Output may
vary with ambient temperature.

7.

Incandescent

Low initial cost. Good color rendition. Good
light control. Instant restart.

Low light output (lumens per watt), short lamp life
(500-2000 hrs). High operating cost.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:L:667))
CH0 0 0 L - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

667

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0668-7 Name: L-668

L

100:
DATE: JAN 19 2006

Time: 5:41:50 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Industrial Lighting Products

3

Select Type of Luminaire
Choice of Reflector
The following list gives broad guidelines for selection of the proper reflectors.
Mounting Height
Above Floor
Reflector
Up to 19 ′
Dome
20′ or more
High bay
Where low footcandle levels will be provided, reflectors may be used at higher mounting heights than shown; where high footcandle levels will be
provided, reflectors may be used at lower mounting heights than shown in the table.

Quick Selector (Environment—Product)
Opposite the industrial environments listed below are the luminaires designed and approved to meet the requirements unique to each
environment. Where different types of light sources might be used, a choice is given.
Environment
Corrosive

Non Metallic
Enclosed & Gasketed

Explosive Vapors
(Class I, Div. 1)

Explosionproof

Combustible Dusts
(Class II, Div. 1)

Dustignition-proof

Moisture, Non-Combustible Dusts,
or Potential for Hazardous Vapors Enclosed & Gasketed
Class I,
Div. 2

Non-Hazardous

668

STIBOINFO((CRH:66008com:L:668))
CH0 0 0 L - 6

Enclosed &
Gasketed

US: 1-866-764-5454

Type
NDA
N2MV
N2MVF
N2MVFB
NFW
N2LPS
EV, EVI
EVLP, EVM Hazard ȿGard®
EVF, EVFDR
EVFT
EVLPF
RCDE/RCDER
ELPS
EVLPFB
EV
EV
DMV Champ®
N2MV Champ®
DMVIG, VMVIG
DMVF, N2MVF
EVM Hazard ȿGard®
FVN
FVS
DMVFB, N2MVFB
Vaporgard TM
CPMV Champ®
NDA
LMV Champ®
DMV Champ®
VMV Champ®
N2MV Champ®
FVN
DMVF, N2MVF
VF
FVS
FMV Champ®
SSFMV Voyager
N2LPS
DMVFB, N2MVFB
NFL

CAN: 1-800-265-0502

Description

Cat. Sect.

General—Incandescent
General—H.I.D.
General—Fluorescent
Emergency—Fluorescent
General—Fluorescent
Emergency—Halogen
General—Incandescent
General—H.I.D.
General—Fluorescent
General—Fluorescent
General—Fluorescent
Flood—Incandescent
Emergency—Halogen
Emergency—Fluorescent
Strobe—Incandescent
General—Incandescent
General—H.I.D.
General—H.I.D.
General—Induction
General—Fluorescent
General—H.I.D.
General—Fluorescent
General—Fluorescent
Emergency—Fluorescent
General—Incandescent
General—H.I.D/Fluorescent
General—Incandescent
General—H.I.D.
General—H.I.D.
General—H.I.D.
General—H.I.D.
General—Fluorescent
General—Fluorescent
General—Fluorescent
General—Fluorescent
Flood—H.I.D.
Flood—H.I.D.
Emergency—Halogen
Emergency—Fluorescent
General—Fluorescent

1L
3L
6L
10L
6L
10L
2L
4L
6L
6L
6L
7L & 9L
10L
10L
11L

691
721
809
923
809
923
709
779
809
809
809
865 & 913
923
923
939

2L
3L
3L
5L
6L
4L
6L
6L
10L
1L
3L & 6L
1L
3L
3L
3L
3L
6L
6L
6L
6L
7L
7L
10L
10L
6L

709
721
721
801
809
779
809
809
923
691
721 & 809
691
721
721
721
721
809
809
809
809
865
865
923
923
809

Copyright© 2006 Cooper Crouse-Hinds

Pg. #

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0669-2 Name: L-669

DATE: JAN 19 2006

Time: 5:41:51 PM Operator: JB

TCP: 15001

Typedriver Name: TS name csm no.: 100

H.I.D. Medium Base
Series - LMV, EVLP 1

Lamps Used With
Cooper Crouse-Hinds
Luminaires

LAMP
WATTS

COLOR: CMYK

ANSI
Ballast

L

MANUFACTURER
GE

Osram/
Sylvania

Phillips

S76
S68
S62
S54
S55

LU35/MED
LU50/MED
LU70/MED
LU100/MED
LU150/MED

LU35/MED
LU50/MED
LU70/MED
LU100/MED
LU150/MED

C35S76/M
C50S68/M
C70S62/M
C100S54/M
C150S55/M

M98
M90
M57

MXR70/U/MED
MXR100/U/MED
MVR175/U/MED

MP70/U/MED
MP100/U/MED
M175/U/MED

MHC70/U/M/3K
MHC100/U/M/3K
MH175/U/M

MXR150/U/MED
MXR175/VBU/MED/PA

MP150/U/MED

Venture

High Pressure Sodium
35
50
70
100
150

Metal Halide
70
100
175

MH70W/U
MH100W/U

Pulse Start Metal Halide
150
175

M102
M137

US: 1-866-764-5454

STIBOINFO((CRH:66008com:L:669))
CH0 0 0 L - 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

MH150W/U/PS
MS175W/BU/MED/PS

669

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0670-2 Name: L-670

L

LAMP
WATTS

DATE: JAN 19 2006

Time: 5:41:52 PM Operator: JB

TCP: 15001

Typedriver Name: TS name csm no.: 100

H.I.D. Medium Base
Series - LMV, EVLP 1

Lamps Used With
Cooper Crouse-Hinds
Luminaires

ANSI
Ballast

COLOR: CMYK

MANUFACTURER

MANUFACTURER

Lumens/Life (hrs)
GE

O/S

Ph

S76
S68
S62
S54
S55

2250/16K
4000/24K
6400/24K
9500/24K
16000/24K

2250/16K
4000/24K
6300/24K
9500/24K
15800/24K

2250/24K
4000/24K
6300/24K
9500/24K
16000/24K

M98
M90
M57

5500/12K
9000/15K
13600/10K

5200/15K
8500/15K
14400/10K

6200/10K
9300/12.5K
13500/10K

12500/15K
17700/15K

13300/15K

Bulb
Venture

GE

O/S

PH

B17
B17
B17
B17
B17

E17
E17
E17
E17
E17

ED17
ED17
ED17
ED17
ED17

5600/15K
9000/15K

BD17
BD17
BD17

E17
E17
ED17

ED17
ED17
ED17

14000/15K
17500/15K

BD17
BD17

E17
E17

Venture

High Pressure Sodium
35
50
70
100
150

Metal Halide
70
100
175

ED17
ED17

Pulse Start Metal Halide
150
175

670

STIBOINFO((CRH:66008com:L:670))
CH0 0 0 L - 0

M102
M137

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

ED17
ED17

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0671-3 Name: L-671

DATE: JAN 19 2006

Time: 5:41:52 PM Operator: JB

TCP: 15001

Typedriver Name: TS name csm no.: 100

H.I.D. Mogul Base
Series - DMV, VMV, CPMV,
FMV, F2MV, EVLP 0, FZD

Lamps Used With
Cooper Crouse-Hinds
Luminaires

LAMP
WATTS

COLOR: CMYK

ANSI
Ballast

L

MANUFACTURER
GE

Osram/
Sylvania

Phillips

Venture

High Pressure Sodium
50
70
100
150
150 (100V)

S68
S62
S54
S55
S56

LU50
LU70
LU100
LU150/55
LU150/100

LU50
LU70
LU100
LU150/55
LU150/100

C50S68
C70S62
C100S54
C150S55
C150S56

200
250
310
400
1000

S66
S50
S67
S51
S52

LU200
LU250
LU310
LU400
LU1000

LU200
LU250
LU310
LU400
LU1000

C200S66
C250S50
C310S67
C400S51
C1000S52

Metal Halide
70
100
175
250
400
400
1000
1500

M98
M90
M57
M58
M59
M59
M47
M48

MH70W/U/ED28
MH100W/U/ED28
MVR175/U
MVR250/U
MVR400/U
MVR400/U/ED28
MVR1000/U
MVR1500/HBD

Pulse Start Metal Halide
150
175
200
250
320
350
400

1000

M102
M137
M136
M138
M138
M132
M131
M131
M135
M135
M135
M135
M141

M175/U
M250U
M400/U
M400/U/BT-28
M1000/U
M1500/BD

MH175/U
MH250/U
MH400/U
MH400/U/ED28
MH1000/U
MH1500/BD

(Base up+–15%)

(Base up+–15%)

MXR175/VBU/PA

MS175/BU/PS

MXR250/VBU/PA

MS250/BU/PS

MXR320/VBU/PA

MS320/PS/BU-ONLY

MS320W/BU/PS

MXR400/VBU/PA

MS400/PS/BU-ONLY

MS400/BU/PS

HR100A38
HR175A39
HR250A37
HR400A33
HR1000A36

H38HT-100
H39KB-175
H37KB-250
H33CD-400
H36GV-1000

H38HT-100
H39KB-175
H37KB-250
H33CD-400
H36GV-1000

HQI-DE 70/WDX

CDM70/TD/830

MH150W/U/ED28/PS
MS175W/BU/PS
MH200W/U/PS
MH250W/HBU/PS
MH250W/HBD/PS
MH320W/U/ED28/PS
MH350W/U/PS
MH350W/U/ED28/PS
MH400W/HBU/PS
MH400W/HBD/PS
MH400W/HBU/ED28/PS
MH400W/HBD/ED28/PS

Mercury Vapor
100
175
250
400
1000

H38
H39
H37
H33
H36

HID Double Contact Metal Halide for EVP Series
70W

CMH70/TD/830/R7S

US: 1-866-764-5454

STIBOINFO((CRH:66008com:L:671))
CH0 0 0 L - 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

671

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0672-3 Name: L-672

Time: 5:41:53 PM Operator: JB

ANSI
Ballast

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

H.I.D. Mogul Base
Series - DMV, VMV, CPMV,
FMV, F2MV, EVM, EVLP 0, FZD

Lamps Used With
Cooper Crouse-Hinds
Luminaires

L

LAMP
WATTS

DATE: JAN 19 2006

MANUFACTURER

MANUFACTURER

Lumens/Life (hrs)
GE

O/S

Ph

Bulb
Venture

GE

O/S

PH

Venture

High Pressure Sodium
50
70
100
150
150 (100V)

S68
S62
S54
S55
S56

4000/24K
6400/24K
9500/24K
16000/24K
15000/24K

4000/24K
6300/24K
9500/24K
16000/24K
15700/24K

4000/24K
6300/24K
9500/24K
16000/24K
16000/24K

ED231/2
ED231/2
ED231/2
ED231/2
ED28

ET231/2
ET231/2
ET231/2
ET231/2
BT28

ED231/2
ED231/2
ED231/2
ED231/2
ED28

200
250
310
400
1000

S66
S50
S67
S51
S52

22000/24K
28000/24K
37000/24K
51000/24K
140000/24K

22000/24K
29000/24K
37000/24K
50000/24K
130000/24K

22000/24K
285000/24K
37000/24K
50000/24K
140000/24K

ED18
ED18
ED18
ED18
E25

ET18
ET18
ET18
ET18
E25

ED18
ED18
ED18
ED18
E25

Metal Halide
70
100
175
250
400
400
1000
1500

M98
M90
M57
M58
M59
M59
M47
M48

5600/15K
9000/15K
13600/10K
20800/10K
36000/20K
36000/20K
105000/12K
155000/3K

14400/10K
22000/10K
36000/20K
36000/20K
110000/15K
155000/3K

13500/10K
20500/20K
36000/20K
36000/20K
110000/12K
165000/3K

ED28
ED28
ED28
ED28
ED37
ED28
BT56
BT56

BT28
BT28
BT37
BT28
BT56
BT56

ED28
ED28
ED37
ED28
BT56
BT56

Pulse Start Metal Halide
150
175
200
250
320
350
400

1000

M102
M137
M136
M138
M138
M132
M131
M131
M135
M135
M135
M135
M141

17200/15K

16000/15K

23000/15K

23800/15K

31000/15K

32000/20K

44000/20K

41000/20K

44000/20K

14000/15K
17500/15K
21000/15K
25000/15K
25000/15K
33000/20K
37000/20K
37000/20K
44000/20K
44000/20K

ED231/2

ED28

ED28

ED28

ED28

BT28

ED28

ED37

BT37

ED37

ED231/2
ED28
ED28
ED37
BT56

ET231/2
BT28
BT28
BT37
BT56

ED231/2
ED28
ED28
ED37
BT56

44000/20K

Mercury Vapor
100
175
250
400
1000

672

STIBOINFO((CRH:66008com:L:672))
CH0 0 0 L - 0

H38
H39
H37
H33
H36

3850/24K
7850/24K
11000/24K
21000/24K
57000/24K

4000/24K
7700/24K
11600/24K
20500/24K
55200/24K

US: 1-866-764-5454

4100/24K
7900/24K
12100/24K
21000/24K
57500/24K

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

ED28
ED28
ED28
ED28
ED28
ED28
ED37
ED28
ED37
ED37
ED28
ED28

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0673-3 Name: L-673

DATE: JAN 19 2006

Time: 5:43:00 PM Operator: JB

BASE

TCP: 15001

Typedriver Name: TS name csm no.: 100

Fluorescent Lamps

Lamps Used With
Cooper Crouse-Hinds
Luminaires

LAMP
WATTS

COLOR: CMYK

LUMINAIRE
SERIES

L

MANUFACTURER
GE

Osram/
Sylvania

Phillips

F5BX/SPX41/840
F7BX/SPX35/835
F9BX/SPX35/835
F13DBX23T4/SPX35

CF5DS/841
CF7DS/835
CF9DS/835
CF13DD/835

PL-S5W/27
PL-S7W/35
PL-S9W/35
PL-C13W/35/USA

F26TBX/SPX35/A/4P

CF26DT/E/IN/835

PL-T26W/35/4P/ALTO

F32TBX/SPX35/A/4P

CF32DT/E/IN/835

PL-T32W/35/4P/ALTO

F42QBX/SPX35/A/4P

CF42DT/E/IN/835

PL-T42W/35/4P/ALTO

F39/36/BX/SPX35
F40/30BX/SPX35

FT36DL/835
FT40DL/835/RS

PL-L36W/35
PL-L40W/35/RS

F32T8/SP35

F032/735

F32T8/TL735/ALTO

F40CW/RS/WM

F40CW/SS

F40CW/RS/EW/ALTO

F48T12/CW/HO

F48T12/CW/HO

F48T12/CW/HO

F48T12/CW/1500

F48T12/CW/VHO

F48T12/CW/VHO

Compact
5W-T4
7W-T4
9W-T4
13W-T4

G23
G23
G23
GX23-2

26W-T4

GX24q-3

32W-T4

GX24q-3

42W-T4

GX24q-4

VF
VF
VF
DMVF (Disc)
DMVF, N2MVF,
CPMVF, EVLPF
DMVF, N2MVF,
CPMVF, EVLPF
DMVF, N2MVF,
CPMVF, EVLPF

Long Twin Tube
70
40

2G11
2G11

EVFT
NFL, FVS

Linear
32W-T8
40(34)W-T12
60W (800ma)-T12
HIGH OUTPUT
110W (1500ma)-T12
VERY HIGH OUTPUT

Medium
Bipin
Medium
Bipin
Recessed
Double Contact
Recessed
Double Contact

NFL, FVN, EVF,
EVFDR
NFL, FVN, EVF,
EVFDR
FVN, EVF,
EVFDR
EVF, EVFDR

US: 1-866-764-5454

STIBOINFO((CRH:66008com:L:673))
CH0 0 0 L - 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

673

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0674-3 Name: L-674

DATE: JAN 19 2006

Time: 5:43:04 PM Operator: JB

Lamps Used With
Cooper Crouse-Hinds
Luminaires

L

LAMP
WATTS

BASE

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Fluorescent Lamps

LUMINAIRE
SERIES

MANUFACTURER

GE

Lumens/Life (Hrs)
Osram/Sylvania

Phillips

250/10K
400/10K
600/10K
810/10K

230/10K
400/10K
580/10K
780/10K

250/10K
400/10K
600/10K
860/10K

1800/10K

1800/10K

1800/10K

2200/10K

2400/10K

2400/10K

3200/10K

3200/10K

3200/10K

2850/12K
3150/20K

2900/12K
3150/20K

2900/12K
3150/20K

Compact
5W-T4
7W-T4
9W-T4
13W-T4

G23
G23
G23
GX23-2

26W-T4

GX24q-3

32W-T4

GX24q-3

42W-T4

GX24q-4

VF
VF
VF
DMVF (Disc)
DMVF, N2MVF,
CPMVF, EVLPF
DMVF, N2MVF,
CPMVF, EVLPF
DMVF, N2MVF,
CPMVF, EVLPF

Long Twin Tube
70
40

2G11
2G11

EVFT
NFL, FVS

Linear
32W-T8
40(34)W-T12
60W (800ma)-T12
HIGH OUTPUT
110W (1500ma)-T12
VERY HIGH OUTPUT

674

STIBOINFO((CRH:66008com:L:674))
CH0 0 0 L - 0

Medium
Bipin
Medium
Bipin
Recessed
Double Contact
Recessed
Double Contact

NFL, FVN, EVF,
EVFDR
NFL, FVN, EVF,
EVFDR
FVN, EVF,
EVFDR

2850/20K

2800/20K

2850/20K

2650/20K

2700/20K

2650/20K

4050/12K

4050/12K

4050/12K

EVF, EVFDR

6200/10K

6600/10K

7050/12K

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0675-2 Name: L-675

100:
DATE: JAN 19 2006

Time: 5:43:04 PM Operator: JB

EXLD

50W PAR20

EVTL

52W A19
58W A19

ELG
ELG

60W T10
65W BR30
75W ER30
100W A19

EXL
EVO2376
EVO2376
EV 40 Series
V160, EV160, EVH,
EV 15 Series
VS
Suffix QTZ
Vaporgard 150W
EV 10 Series
EV 20 Series
V Series
RCDE6
Vaporgard 200W
EV 10 Series
Vaporgard 200W
EV 15 Series
EV 15 Series
EV 20 Series
EV 30 Series

100W A23
100W D.C. Bay
150W A21
150W A23
150W PAR38
200W A23
200W A25
200W PS25
200W PS30

300W PS25

300W PS30
300W R40
300W PS35
500W PS40
500W PAR64

Vapourgard 300W
NDA
EV 15 Series
Vaporgard 300W
EV 20 Series
EV 15 Series
RCDE6
EV 30 Series
EV 30 Series
RCDE10

US: 1-866-764-5454

STIBOINFO((CRH:66008com:L:675))
CH0 0 0 L - 0

Typedriver Name: TS name csm no.: 100

L

LUMINAIRE
SERIES

25W T10

100W A21

TCP: 15001

Incandescent & Quartz
(Halogen) Lamps

Lamps Used With
Cooper Crouse-Hinds
Luminaires

MAX WATTS AND
BULB TYPE

COLOR: CMYK

MANUFACTURER
GE

Osram/
Sylvania

Phillips

25T10
50PAR20/H/SP10
50PAR20/H/FL25

25T10
50PAR20/CAP/NSP
50PAR20/CAP/NFL

25T10
50PAR20/HAL/NSP9
50PAR20/HAL/NFL30

60A52WMP/98

60A52/SS/XL
58A19/62

60A-52A/99/EW

60T10
75R30/SP/65WM
75ER30
100A (IF)

60T10
65BR30/SP
75ER30
100A (IF)

60T10
65BR30/SP20
75ER30
100A (IF)

100A21 (IF)

100A21 (IF)

100A21 (IF)

100A23 120V
Q100CL/DC

100A23
100Q/CL/DC

100A23
100Q/CL/DC

150A (IF)

150A (IF)

150A (IF)

150A23 (IF)
150PAR/FL

150A23/CL
150PAR38/2FL

200A23 (IF)

200A (IF)
200A25/35

200PS25/99XL
200 130V

200PS/CL 130V

300M

200 130V

300M

300M/99 (130v)

300M/CL

300M/PS30

300R/FL
300
500PS40
500PAR64/MFL

300R40/FL
300/CL

300BR/FL
300
500PS40
500PAR64/MFL

CAN: 1-800-265-0502

500PAR64/MFL

Copyright© 2006 Cooper Crouse-Hinds

675

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0676-2 Name: L-676

DATE: JAN 19 2006

Time: 5:43:05 PM Operator: JB

MAX WATTS AND
BULB TYPE

25W T10
50W PAR20
52W A19
58W A19
60W T10
65W BR30
75W ER30
100W A19
100W A21
100W A23
100W D.C. Bay
150W A21
150W A23
150W PAR38
200W A23
200W A25
200W PS25
200W PS30
300W PS25

300W PS30
300W R40
300W PS35
500W PS40
500W PAR64

676

STIBOINFO((CRH:66008com:L:676))

LUMINAIRE
SERIES

EXLD
EVTL
ELG
ELG
EXL
EVO2376
EVO2376
EV 40 Series
V160, EV160, EVH,
EV 15 Series
VS
Suffix QTZ
Vaporgard 150W
EV 10 Series
EV 20 Series
V Series
RCDE6
Vaporgard 200W
EV 10 Series
Vaporgard 200W
Ev 15 Series
EV 15 Series
EV 20 Series
EV 30 Series
Vapourgard 300W
NDA
EV 15 Series
Vaporgard 300W
EV 20 Series
EV292 Series
RCDE6
EV 30 Series
EV 30 Series
RCDE10

US: 1-866-764-5454

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Incandescent & Quartz
(Halogen) Lamps

Lamps Used With
Cooper Crouse-Hinds
Luminaires

L

CH0 0 0 L - 0

100:

MANUFACTURER

GE

Lumens
O/S

248
570
570
670
630
740
775
850
1710

232
530
530
650
630
630
640
750
1750

1710

MANUFACTURER

Ph

GE

Life-Hours
O/S

PH

260
550
550
564
630
745

1650

1000
2500
2500
2500
3000
1000
2000
2000
750

1000
2500
2500
2500
3000
1000
2000
2000
750

1000
2000
2000
4250
3000
1000
2000
2000
750

1690

1680

750

750

750

1600
1600

1600

1730
1600

750
2000

750
2000

750
2000

2850

2780

2850

750

750

750

1660

2810
1660

2475
1660

2000

750
2000

1275
2000

3930

3800

750

750

2720

2720

2720

3500

3500

3500

3000

3000

3000

2500

2500

2500

2725

2665

2825

1950

1875

2120

6280

750

750

750

6200

3935

5870

6100

6800

7500

7500

3700
5820
9900
6500

3030
5700
10100

np
5700
10100

2000
1000
1000
2000

2000
1000
1000
2000

2000
1000
1000
2000

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0677-2 Name: L-677

DATE: JAN 19 2006

Time: 5:43:06 PM Operator: JB

TCP: 15001

Typedriver Name: TS name csm no.: 100

High Pressure Sodium
Data

Ballasts Used With
Cooper Crouse-Hinds
Luminaires

L

Watts

ANSI
Code

Volts

Type
R/HX/CWA

Starting
Current

Operating
Current

Input
Watts

35

S76

120

R-HPF

0.8

0.4

46

CHRBS 035

/120

50

S68

120
120/277
220/240-50 Hz

R-HPF
HX-HPF
HX-HPF

1.0
0.7/0.3
0.3/0.3

0.6
0.6/0.3
0.6/0.6

62
66
66

CHRBS 050
CHRBS 050
CHRBS 050

/120
/DT
/220 50

S62

120
120/208/240/277
120/277/347
220
420
220/240-50Hz

R-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF

0.9
0.8/0.5/0.4/0.4
.8/.4/.3
0.4
0.2
.5/.4

0.8
0.8/0.5/0.4/0.4
0.8/0.4/0.3
0.4
0.2
.5/.4

86
91
93
91
93
94

CHRBS
CHRBS
CHRBS
CHRBS
CHRBS
CHRBS

070
070
070
070
070
070

/120
/MT
/TT
/220
/480
/220 50

S54

120
120/208/240/277
120/277/347
220
480
220/240-50 Hz

R-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF

1.5
1.3/0.8/0.7/0.6
1.3/0.6/0.5
0.7
0.4
0.5/0.5

1.1
1.2/0.7/0.6/0.5
1.2/0.5/0.4
0.6
0.3
0.7/0.6

115
130
130
130
130
130

CHRBS
CHRBS
CHRBS
CHRBS
CHRBS
CHRBS

100
100
100
100
100
100

/120
/MT
/TT
/220
/480
/220 50

150
(55v)

S55

120
120/208/240/277
120/277/347
220
480
220/240-50 Hz

R-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF

2.3
2.0/1.2/1.0/0.9
2.0/0.9/0.5
1.1
0.5
0.9/0.8

1.5
1.7/1.0/0.8/0.7
1.7/0.7/0.6
0.9
0.4
0.9/0.8

170
188
188
188
188
188

CHRBS
CHRBS
CHRBS
CHRBS
CHRBS
CHRBS

150
150
150
150
150
150

/120
/MT
/TT
/220
/480
/220 50

150
(100v)

S56

120/208/240/277
480
220/240-50 Hz

CWA
CWA
R-PFC

1.2/0.7/0.6/.05
0.3
0.9/1.0

1.8/1.0/0.9/0.8
0.4
0.9/0.8

188
188
175

CHRBS 150
CHRBS 150
CHRBS 150

200

S66

12-/208/240/277
480

CWA
CWA

1.4/0.8/0.7/0.6
0.4

2.4/1.4/1.2/1.0
0.6

250
250

CHRBS 200 /MT
CHRBS /200 /480

S50

120
120/208/240/277
120/277/347
220
480
230-50 Hz

CWA
CWA
CWA
CWA
CWA
CWA

1.7
1.7/1.0/0.8/0.7
1.7/0.7/0.6
0.9
0.4
1.0

2.5
2.5/1.5/1.3/1.1
2.7/1.2/0.9
1.5
0.7
1.4

295
295
295
295
310
300

CHRBS
CHRBS
CHRBS
CHRBS
CHRBS
CHRBS

250
250
250
250
250
250

/120
/MT
/TT
/220
/480
/220 50

S51

120
120/208/240/277
120/277/347
220
480
230-50 Hz

CWA
CWA
CWA
CWA
CWA
CWA

3.3
3.3/1.8/1.5/1.4
3.3/1.4/1.0
1.6
0.8
1.9

3.8
3.8/2.2/1.9/1.7
3.8/1.7/1.3
2.1
1.0
2.0

457
464
464
457
464
465

CHRBS
CHRBS
CHRBS
CHRBS
CHRBS
CHRBS

400
400
400
400
400
400

/120
/MT
/TT
/220
/480
/220 50

S52

120/208/240/277
120/277/347
220
480
220/240-50 Hz

CWA
CWA
CWA
CWA
CWA

6.4/3.8/3.2/2.8
6.4/2.8/2.2
3.6
1.6
6.0/5.6

9.5/5.5/4.8/4.2
9.5/4.2/3.3
5.0
2.3
5.2/4.8

1100
1100
1100
1100
1100

CHRBS
CHRBS
CHRBS
CHRBS
CHRBS

1000
1000
1000
1000
1000

/MT
/TT
/220
/480
/220 50

70

100

250

400

1000

US: 1-866-764-5454

STIBOINFO((CRH:66008com:L:677))
CH0 0 0 L - 0

COLOR: CMYK

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Kit Cat No.

/MT CE
/480 CE
/220 50 CE

677

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

100:

JOB: CRMAIN06-0678-3 Name: L-678

DATE: JAN 19 2006

Time: 5:43:06 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Pulse Start Metal Halide
Data

Ballasts Used With
Cooper Crouse-Hinds
Luminaires

L

Watts

ANSI
Code

Volts

Type
R/HX/CWA

Starting
Current

Operating
Current

Input
Watts

150

M102

120/208/240/277
120/277/347

HX-HPF
HX-HPF

1.8/1.3/0.9/0.8
1.8/0.8/0.7

1.6/1.0/0.8/0.7
1.6/0.7/0.6

185
185

CHRBM 150
CHRBM 150

/MT
/TT

S828
S828

175

M137

120/208/240/277
120/277/347

Super CWA
Super CWA

1.0/0.6/0.5/0.4
0.8/0.4/0.3

1.8/1.1/0.9/0.8
1.9/0.8/0.7

208
208

CHRBM 175
CHRBM 175

/MT
/TT

S828
S828

200

M136

120/208/240/277
120/277/347
480

Super CWA
Super CWA
Super CWA

0.80.4/0.4/0.3
0.7/0.3/0.3
0.2

2.0/1.2/1.0/0.9
2.1/0.9/0.7
0.5

232
232
232

CHRBM 200
CHRBM 200
CHRBM 200

/MT
/TT
/480

S828
S828
S828

250

M138

120/208/240/277
120/277/347

Super CWA
Super CWA

2.3/1.3/1.2/1.0
2.0/0.9/0.8

2.5/1.5/1.3/1.1
2.5/1.1/0.9

288
290

CHRBM 250
CHRBM 250

/MT
/TT

S828
S828

M132

120/208/240/277
120/277347
220
480
230/50

Super CWA
Super CWA
Super CWA
Super CWA
Super CWA

1.8/1.1/0.9/0.8
2.2/1.0/0.7
1.4
0.5
1.1

3.3/1.9/1.7/1.4
3.3/1.4/1.1
1.7
0.8
1.6

368
368
365
368
365

CHRBM
CHRBM
CHRBM
CHRBM
CHRBM

250
250
250
250
250

/MT
/TT
/220
/480
/220 50

S828
S828
S828
S828
S828

M135

120/208/240/277
120/277/347
480
230/50

Super CWA
Super CWA
Super CWA
Super CWA

2.9/1.7/1.5/1.3
3.2/1.4/1.1
0.8
2.0

3.8/2.2/1.9/1.7
3.8/1.7/1.4
1.0
2.1

452
450
452
454

CHRBM
CHRBM
CHRBM
CHRBM

400
400
400
400

/MT
/TT
/480
/220 50

S828
S828
S828
S828

M141

120/208/240/277
347
480
220/240-50 Hz

Super CWA
Super CWA
Super CWA
CWA

7.8/4.0/3.7/3.2
2.3
1.7
4.5/4.1

9.0/5.2/4.5/3.9
3.2
2.4
5.0/4.5

1080
1075
1075
1090

CHRBM
CHRBM
CHRBM
CHRBM

1000
1000
1000
1000

/MT
/347
/480
/220 50

S828
S828
S828
S828

320

400

1000

678

STIBOINFO((CRH:66008com:L:678))
CH0 0 0 L - 0

98:

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Kit Cat No.

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0679-2 Name: L-679

DATE: JAN 19 2006

Time: 5:43:07 PM Operator: JB

70

100

175

250

400

1000

1500

STIBOINFO((CRH:66008com:L:679))

Typedriver Name: TS name csm no.: 100

L

ANSI
Code

Volts

Type
R/HX/CWA

Starting
Current

Operating
Current

Input
Watts

M98

120/208/240/277
120/277/347
220
220/240-50 Hz

HX-HPF
HX-HPE
HX-HPF
HX-HPF

0.6/0.3/0.3/0.3
0.6/0.2/0.2
0.4
0.7/0.6

0.8/0.5/0.4/0.4
0.8/0.4/0.3
0.5
0.5/0.4

88
88
94
95

CHRBM
CHRBM
CHRBM
CHRBM

070
070
070
070

/MT
/TT
/220
/220 50

M90

120/208/240/277
120/277/347
220
480
220/240-50 Hz

HX-HPF
HX-HPF
HX-HPF
HX-HPF
HX-HPF

1.2/0.8/0.7/0.6
1.2/0.5/0.4
0.9
0.3
0.7/0.7

1.2/0.7/0.6/0.5
1.2/0.5/0.4
0.6
0.3
0.7/0.6

129
129
129
132
129

CHRBM
CHRBM
CHRBM
CHRBM
CHRBM

100
100
100
100
100

/MT
/TT
/220
/480
/220 50

M57

120
120/208/240/277
120/277/347
220
480
230/50

CWA
CWA
CWA
CWA
CWA
CWA

1.3
1.3/0.8/0.7/0.6
1.3/0.6/0.5
0.6
0.4
0.8

1.8
1.8/1.1/0.9/0.8
1.8/0.8/0.7
1.0
0.5
1.1

210
210
210
210
210
210

CHRBM
CHRBM
CHRBM
CHRBM
CHRBM
CHRBM

175
175
175
175
175
175

/120
/MT
/TT
/220
/480
/220 50

M58

120
120/208/240/277
120/277/347
220
480
230/50

CWA
CWA
CWA
CWA
CWA
CWA

1.0
1.0/0.6/0.5/0.5
2.2/1.0/0.8
1.4
0.6
1.0

2.6
2.6/1.5/1.3/1.1
2.5/1.1/0.9
1.5
0.6
1.3

294
294
295
295
295
290

CHRBM
CHRBM
CHRBM
CHRBM
CHRBM
CHRBM

250
250
250
250
250
250

/120
/MT
/TT
/220
/480
/220 50

M59

120
120/208/240/277
120/277/347
220
480
230/50

CWA
CWA
CWA
CWA
CWA
CWA

3.0
3.5/2.0/1.8/1.5
3.5/1.5/1.2
1.9
0.9
1.4

4.0
4.0/2.2/2.0/1.8
4.0/1.8/1.4
2.2
1.0
2.1

456
458
460
458
462
462

CHRBM
CHRBM
CHRBM
CHRBM
CHRBM
CHRBM

400
400
400
400
400
400

/120
/MT
/TT
/220
/480
/220 50

M47

120/208/240/277
120/277/347
220
480
220/240-50 Hz

CWA
CWA
CWA
CWA
CWA

7.84.0/3.7/3.2
7.8/3.2/2.5
3.9
1.9
4.5/4.1

9.0/5.2/4.5/3.9
9.0/3.9/3.2
4.9
2.3
5.0/4.5

1080
1080
1080
1080
1090

CHRBM
CHRBM
CHRBM
CHRBM
CHRBM

1000 /MT
1000 /TT
1000 /220
1000 /480
1000 /220 50

M48

120/208/240/277
120/277347
220
480
220/240-50 Hz

CWA
CWA
CWA
CWA
CWA

13.4/7.7/6.7/5.7
13.4/5.7/4.6
7.3
3.3
6.9/6.3

13.5/7.8/6.8/5.9
13.5/5.9/4.8
7.4
3.4
7.5/6.9

1605
1615
1605
1625
1605

CHRBM
CHRBM
CHRBM
CHRBM
CHRBM

1500 /MT
1500 /TT
1500 /220
1500 /480
1500 /220 50

US: 1-866-764-5454

CH0 0 0 L - 0

TCP: 15001

Metal Halide
Data

Ballasts Used With
Cooper Crouse-Hinds
Luminaires

Watts

COLOR: CMYK

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Kit Cat No.

679

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

100:

JOB: CRMAIN06-0680-3 Name: L-680

Watts

100

175

250

400

1000

680

STIBOINFO((CRH:66008com:L:680))

DATE: JAN 19 2006

Time: 5:43:08 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Mercury Vapor
Data

Ballasts Used With
Cooper Crouse-Hinds
Luminaires

L

CH0 0 0 L - 0

98:

ANSI
Code

Volts

Type
R/HX/CWA

Starting
Current

Operating
Current

Input
Watts

H38

120
120/208/240/277
120/277/347
480
220/240-50 Hz

CWA
CWA
CWA
CWA
CWA

1.1
1.1/0.6/0.5/0.5
1.1/0.5/0.4
0.3
0.7/0.6

1.1
1.1/0.6/0.5/0.5
1.1/0.5/0.3
0.3
0.6/0.5

120
125
125
125
125

CHRBC
CHRBC
CHRBC
CHRBC
CHRBC

100
100
100
100
100

/120
/MT
/TT
/480
/220 50

H39

120
120/208/240/277
120/277347
220
480
230/50

CWA
CWA
CWA
CWA
CWA
CWA

1.6
1.6/1.0/0.8/0.7
1.3/0.6/0.5
0.6
0.4
0.8

1.9
1.9/1.1/1.0/0.8
1.8/0.8/0.7
1.0
0.4
1.1

205
205
210
210
200
210

CHRBC
CHRBC
CHRBC
CHRBC
CHRBC
CHRBC

175
175
175
175
175
175

/120
/MT
/TT
/220
/480
/220 50

H37

120
120/208/240/277
120/277/347
220
480
230/50

CWA
CWA
CWA
CWA
CWA
CWA

2.5
2.5/1.5/1.3/1.1
2.2/1.0/0.8
1.4
0.6
1.0

2.5
2.5/1.5/1.3/1.1
2.5/1.1/0.9
1.5
0.6
1.3

280
285
295
295
285
290

CHRBC
CHRBC
CHRBC
CHRBC
CHRBC
CHRBC

H33

120/208/240/277
120/277/347
220
480
230/50

CWA
CWA
CWA
CWA
CWA

3.2/2.0/1.7/1.7
3.5/1.5/1.2
1.9
1.0
1.4

3.9/2.2/2.0/1.7
4.0/1.8/1.4
2.1
1.0
2.1

454
460
454
454
462

CHRBC
CHRBC
CHRBC
CHRBC
CHRBC

400
400
400
400
400

/MT
/TT
/220
/480
/220 50

H36

120/208/240/277
120/277/347
220
480
220/240-50 Hz

CWA
CWA
CWA
CWA
CWA

8.0/4.6/4.0/3.5
7.8/3.2/2.5
3.9
1.9
4.5/4.1

9.8/5.6/4.9/4.3
9.0/3.9/3.2
4.9
2.3
5.0/4.5

1080
1080
1080
1080
1090

CHRBC
CHRBC
CHRBC
CHRBC
CHRBC

1000
1000
1000
1000
1000

/MT
/TT
/220
/480
/220 50

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Kit Cat No.

250
250
250
250
250
250

/120
/MT
/TT
/220
/480
/220 50

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0681-2 Name: L-681

DATE: JAN 19 2006

Time: 5:43:08 PM Operator: JB

Ballasts Used With
Cooper Crouse-Hinds
Luminaires

Luminaire
Series

Lamp Type & Watts

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Fluorescent Data

L

Lamp Base

Lamp
No.
Qty.

Ballast
Voltage

Starting
Operating
Amp

Input
Watts

Kit Cat. No.

COMPACT
VF

9W T4

G23

2

120

0.4

22

CHRBF2C18/120

DMVF,
N2MVF,
EVLPF

26W T4
26W T4
26W T4
26W T4
26W T4
26W T4

GX24q-3
GX24q-3
GX24q-3
GX24q-3
GX24q-3
GX24q-3

2
2
2
2
2
2

120
220/240
277
347
DC 12V
DC 24V

0.5
0.3
0.2
0.2
3.6
1.8

55
55
55
44
43
43

CHRBF4C64/UNV
CHRBF4C64/UNV
CHRBF4C64/UNV
CHRBF4C64/347
CHRBF4C64/12VDC
CHRBF4C64/24VDC

DMVF,
N2MVF,
EVLPF

32W T4
32W T4
32W T4
32W T4
32W T4
32W T4

GX24q-3
GX24q-3
GX24q-3
GX24q-3
GX24q-3
GX24q-3

2
2
2
2
2
2

120
220/240
277
347
DC 12V
DC 24V

0.6
0.3
0.3
0.2
4.4
2.2

68
68
68
62
60
60

CHRBF4C64/UNV
CHRBF4C64/UNV
CHRBF4C64/UNV
CHRBF4C64/347
CHRBF4C64/12VDC
CHRBF4C64/24VDC

CPMVF

42W T4
42W T4
42W T4

GX24q-4
GX24q-4
GX24q-4

2
2
2

120
277
347

0.8
0.3
0.3

93
68
80

CHRBF4C84/120
CHRBF4C84/277
CHRBF4C84/347

LONG TWIN TUBE

NFL

40W T5
40W T5
40W T5
40W T5

2G11
2G11
2G11
2G11

1
1
1
1

120
277
347
220/240

0.4
0.2
0.1
0.2

42
42
44
41

CHRBFT40/120
CHRBFT40/277
CHRBFT80/347
CHRBFT80/UNV

FVS

40W T5
40W T5
40W T5
40W T5

2G11
2G11
2G11
2G11

2
2
2
2

120
277
347
220/240

0.6
0.3
0.2
0.3

76
73
70
74

CHRBFT80/UNV
CHRBFT80/UNV
CHRBFT80/347
CHRBFT80/UNV

EVFT

36/39W
36/39W
36/39W

2G11
2G11
2G11

2
2
2

120
277
220/240

0.6
0.3
0.3

74
74
71

CHRBFT78/120
CHRBFT78/277
CHRBFT78/220

Note:
For 3 Lamp luminaires, order one 1 lamp ballast and one 2 lamp, lamp ballast. Add current and watts values
For 4 lamp luminaires, order two 2 lamp, lamp ballasts. Double currents and watts values

US: 1-866-764-5454

STIBOINFO((CRH:66008com:L:681))
CH0 0 0 L - 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

681

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0682-2 Name: L-682

L

100:
DATE: JAN 19 2006

Time: 5:43:09 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Fluorescent
Data

Ballasts Used With
Cooper Crouse-Hinds
Luminaires

Lamp Base

Lamp
No.
Qty.

Ballast
Voltage

Starting
Operating
Amp

Input
Watts

Kit Cat. No.

NFL, FVN,
EVF &
EVFDR

32W T8
32W T8
32W T8
32W T8
32W T8
32W T8
32W T8
32W T8

Med Bipin
Med Bipin
Med Bipin
Med Bipin
Med Bipin
Med Bipin
Med Bipin
Med Bipin

1
1
1
1
2
2
2
2

120
277
347
220/240
120
277
347
220

0.3
0.2
0.1
0.3
0.5
0.2
0.1
0.4

35
35
32
38
58
58
50
58

CHRBFL64/UNV
CHRBFL64/UNV
CHRBFL64/347
CHRBFL64/UNV
CHRBFL64/UNV
CHRBFL64/UNV
CHRBFL64/347
CHRBFL64/UNV

NFL, FVN,
EVF &
EVFDR

40(34W)T12
40(34W)T12
40(34W)T12
40(34W)T12
40(34W)T12
40(34W)T12
40(34W)T12
40(34W)T12

Med Bipin
Med Bipin
Med Bipin
Med Bipin
Med Bipin
Med Bipin
Med Bipin
Med Bipin

1
1
1
1
2
2
2
2

120
277
347
220 50
120
277
347
220/240

0.4
0.2
0.2
0.2
0.6
0.3
0.2
0.2

46
46
52
51
73
80
62
71

CHRBFL80/120
CHRBFL80/277
CHRBFL40/347
CHRBFL40/220 50
CHRBFL80/120
CHRBFL80/277
CHRBFL80/347
CHRBFL80/220

FVN,
EVF &
EVFDR

60W (800ma) T12 HO
60W (800ma) T12 HO
60W (800ma) T12 HO
60W (800ma) T12 HO
60W (800ma) T12 HO
60W (800ma) T12 HO

Recessed Double Contact
Recessed Double Contact
Recessed Double Contact
Recessed Double Contact
Recessed Double Contact
Recessed Double Contact

1
1
1
2
2
2

120
277
220 50
120
277
220 50

0.9
0.5
0.7
1.2
0.5
1.0

79
82
140
133
131
224

CHFBFL120/120
CHFBFL120/277
CHFBFL120/220 50
CHFBFL120/120
CHFBFL120/277
CHFBFL120/220 50

EVF &
EVFDR

110W (1500ma) T12 VHO
110W (1500ma) T12 VHO
110W (1500ma) T12 VHO
110W (1500ma) T12 VHO

Recessed Double Contact
Recessed Double Contact
Recessed Double Contact
Recessed Double Contact

1
1
2
2

120
277
120
277

1.7
0.6
2.2
0.9

130
137
230
241

CHRBFL220/120
CHRBFL220/277
CHRBFL220/120
CHRBFL220/277

Luminaire
Series

Lamp Type & Watts

LINEAR

Note:
For 3 Lamp Luminaires, order one 1 lamp ballast and one 2 lamp, lamp ballast. Add current and watts values
For 4 lamp luminaires, order two 2 lamp, lamp ballasts. Double currents and watts values

682

STIBOINFO((CRH:66008com:L:682))
CH0 0 0 L - 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0683-3 Name: L-683

100:
DATE: JAN 19 2006

Time: 5:43:10 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Industrial Lighting Products

L

4

Calculate the Number of Luminaires Required
For uniform lighting of a specific area, the
lumen method is used to calculate the
number of luminaires required. This method
takes into account not only the direct light
from the luminaire, but also that which is
reflected from the ceiling, walls and floor. As
the calculations will show, the higher the
reflectivity of the surfaces, the fewer number
of luminaires required. Clean, light-colored
surfaces also provide visual comfort.
The Coefficient of Utilization as used in these
calculations makes allowances for light
absorbed by walls and ceiling, and the light
absorbed within the luminaire.
To obtain the Coefficient of Utilization, the
reflection factors of the walls, floors, and
ceiling must be estimated. These
reflectances should be the minimum values
expected just before cleaning or repainting of
the surfaces. The reference below gives
approximate factors for various surfaces.
Reflectance
Color
Factor
White . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80%
Light tints of blue-green, cream, blue,
buff or gray . . . . . . . . . . . . . . . . . . . . . . . . . . 70%
Medium blue-green, yellow, medium
buff, or gray . . . . . . . . . . . . . . . . . . . . . . . . . 50%
Dark gray, medium blue . . . . . . . . . . . . . . . 30%
Dark blue, brown, dark green, and many
wood finishes, such as dark oak and
mahogany . . . . . . . . . . . . . . . . . . . . . . . . . . . 10%
When supplementary lighting (highlighting)
or floodlighting is needed, use the point-bypoint method to determine footcandles at a
specific point or points on the work plane.
This method can also be used with angle
reflectors for lighting of irregular rooms or
where ceiling use is restricted. Candlepower
distribution curves for individual lighting units
are shown on the appropriate catalog pages.

4a

4b

Determine Cavity Ratios

Determine Cavity
Reflectances

There are three Cavity Ratios that should be
determined, as in Figure 1:
Ceiling Cavity Ratio
Room Cavity Ratio
Floor Cavity Ratio
Each of these ratios can be found through
use of Table IV, page 684. Simply find the
appropriate Cavity Depth, whether it is
Ceiling Cavity Depth (hCC), Room Cavity
Depth (hRC), or Floor Cavity Depth (hFC), and
match it with the room length and width to
obtain the Cavity Ratio.
For example, to determine the Ceiling Cavity
Ratio when the Ceiling Cavity Depth (distance
from luminaire to ceiling) is 4′, the width of
the room 20′ and the length 60′, crossreference to Cavity Depth 4.0, width 20,
length 60, and find Ceiling Cavity Ratio of 1.3.
If the Room Cavity Depth (distance from
luminaire to work plane) is 12′, then the Room
Cavity Ratio would be 4.0.

Basic Steps in the Lumen
Method

Effective reflectances of the different room
cavities are determined in Table V, page 685,
by using the estimated ceiling, wall and floor
reflectances together with the corresponding
cavity ratios.
Using the example in Step 4a, we estimate
the wall reflectance at 70% and the ceiling
reflectance at 70%. Using the Ceiling Cavity
Ratio of 1.3 (also from Step 4a) in Table V, we
find the Effective Ceiling Cavity Reflectance is
61%.

4c
Determine Coefficient of
Utilization
The Coefficient of Utilization is determined
from the CU table found on the catalog page
for the previously selected luminaire/lamp
combination.
Using our example again, the three required
factors for use with the CU table would be:
Room Cavity Ratio
(from Step 4a). . . . . . . . . . . . . . . . . . . . . . . . . 4.0
Wall Reflectance
(from Step 4b) . . . . . . . . . . . . . . . . . . . . . . . 70%
Effective Ceiling Cavity Reflectance
(from Step 4b) . . . . . . . . . . . . . . . . . . . . . . . 61%
In most instances some interpolations will be
necessary to obtain the proper Coefficient of
Utilization.
You will note that the table gives Coefficients
of Utilization for a 20% Effective Floor Cavity
Reflectance. Use of this factor for all
applications will provide reasonable
accuracy; however, if more accuracy is
desired, refer to the current Illuminating
Engineering Society Handbook for an
additional detailed step.

(Zonal Cavity Method)
Step 4a
Step 4b
Step 4c
Step 4d
Step 4e
Step 4f

Determine Cavity Ratios
Determine Cavity Reflectances
Determine Coefficient of Utilization
Determine Light Loss Factor
Calculate Lamp Lumens Required
Calculate Number of Luminaires
Required

Figure 1/The three cavities used in
the Lumen Method

US: 1-866-764-5454

STIBOINFO((CRH:66008com:L:683))
CH0 0 0 L - 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

683

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0684-2 Name: L-684

L

100:
DATE: JAN 19 2006

Time: 5:43:10 PM Operator: JB

COLOR: CMYK

TCP: 15001

Industrial Lighting Products

Table IV/Cavity Ratios

684

STIBOINFO((CRH:66008com:L:684))
CH0 0 0 L - 8

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0685-2 Name: L-685

100:
DATE: JAN 19 2006

Time: 5:43:12 PM Operator: JB

COLOR: CMYK

TCP: 15001

Industrial Lighting Products

Typedriver Name: TS name csm no.: 100

L

Table V/Effective Ceiling Reflectance

US: 1-866-764-5454

STIBOINFO((CRH:66008com:L:685))
CH0 0 0 L - 9

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

685

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0686-6 Name: L-686

DATE: JAN 19 2006

Time: 5:43:13 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Industrial Lighting Products

L

4d

4f

Determine Light Loss Factor

Calculate Number of Luminaires Required

The light loss factor takes into account two things: lamp
light output dropoff (lamp lumen depreciation) and dirt
accumulation on the luminaire, lamp and reflector. The
table below lists suggested total light loss factors
according to light source and operating conditions.
(Other factors that may affect light loss, such as voltage
to luminaire, luminaire ambient temperature (fluorescent)
and ballast operating characteristics, should also be
considered.)

Formula:

Typical Lamp Lumens
from list below:ɍ ɍ
Lamp
Induction

Watts
55
85
165

Lumens
3500
6000
12000

Life
(hours)
100,000
100,000
100,000

Suggested Total Light Loss Factors
Operating Conditions

Incandescent
(inside frosted)

100
150
200 A-23;
PS-30, PS-25
300 PS-25;
PS-30;
PS-35;
500

1750
2880
4010
3710
6360
6110
5820
10850

750
750
750
750
750
750
1000
1000

Mercury Vapor
(deluxe white)

100
175
250
400
1000

4200
8600
12100
22500
63000

24000
24000
24000
24000
24000

Metal Halide
(clear)

70
100
175
250
400
1000

5600
7800
14000
20500
36000
110000

10000
10000
10000
10000
20000
12000

High Pressure
Sodium
(clear)

35
50
70
100
150
200
250
400
1000

2250
4000
6400
9500
16000
22000
27500
50000
140000

16000
24000
24000
24000
24000
24000
24000
24000
24000

Linear
Fluorescent

32 (T8)
40 (Slimline)
40 (Rapid Start)
60 (800 ma)
110 (1500 ma)
215 (1500 ma)

2900
3000
3150
4300
6850
16000

20000
9000
20000
12000
10000
12000

Compact
Fluorescent

5
7
9
13
26
32

250
400
600
860
1800
2400

10000
10000
10000
10000
10000
10000

Long Twin Tube
Fluorescent

39
40

2850
3150

12000
20000

CLEAN
Clean air, free of
fumes and dust,
luminaires
scheduled to be
cleaned
frequently, and
lamps replaced
systematically.

AVERAGE

Luminaires Required =

DIRTY

Less favorable
atmospheric
conditions,
luminaires
cleaned at fairly
frequent intervals,
and lamps
replaced only
after burnout.

Quite dirty
locations and
work
atmospheres,
infrequent
maintenance of
lighting
equipment.

Lamp and Luminaire Clean

Average

Dirty

Incandescent
Quartz
Mercury
Metal Halide
High Pressure
Sodium
Fluorescent

.74
.82
.70
.64

.69
.76
.65
.59

.64
.70
.60
.55

.77
.71

.71
.66

.66
.61

4e
Calculate Lamp Lumens Required
Formula: Total Lamp Lumens =
Footcandles[†] X Area of Room (sq. ft.)
Coefficient of Utilization[‡] X Light Loss Factor[ɍ]

[†] from Table 1, page 665 or IES Handbook
[‡] from catalog page on luminaire selected—and calculated from 4b
[ɍ] from above
ɍɍ For lamp data check current lamp manufacturing catalog. Variances exist between

Total Lamp Lumens
Total Lamp Lumens per Luminaire

In using the formula make sure you divide by the total lamp lumens
per luminaire. For example, if an EVF24022, 4 lamp, 32 watt, T8
luminaire is being used, you would multiply the total lamp
lumens by 4. (4 × 2900 or 11,600 lumens.)

manufacturers.

Continued

686

STIBOINFO((CRH:66008com:L:686))
CH0 0 L - 1 0

US: 1-866-764-5454

CAN: 1-800-265-0502

©

Copyright 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0687-5 Name: L-687

DATE: JAN 19 2006

Time: 5:43:13 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Industrial Lighting Products

4f (continued)
EXAMPLE: Lumen Method
Requirement:
Design a system for lighting a room classified
Class I, Division 2, Group D
Assumptions:
a) Room dimensions – 40′ wide; 80′ long; 15′
high
b) Luminaires to be suspended 3′ from
ceiling; work plane is 4′ above floor
c) Ceiling is off-white; walls are light gray;
floor is concrete
d) Good maintenance conditions exist
e) Lighting system will be operated 16 hours
daily; 5 days a week
f) Color rendition is not critical
Using the Coefficient of Utilization worksheet,
follow procedure given below. Answers to our
example are on the worksheet.

L

(G) Compute Total Lamp Lumens required.
Formula
(FC x Area) 50 x 80 x 40
= 278,169 Lumens
(CU x LLF) .747 x 0.77
Therefore, the number of VMVS3A150G
luminaires required
Total Lamp Lumens 278,169
= 17.4
Lamp Lumens per luminaire (page 686) 16,000
= 17 VMVS3A150G luminaires with RD70 dome reflectors (use 18 luminaires, see page 685).
=

Coefficient of Utilization Worksheet

Step #1. Determine required illumination
level in FOOTCANDLES (FC) – Table 1, page
665.
Step #2. Select type of lamp – pages 666
and 667. For the room size in example,
considering long hours of operation and
color rendition not being critical, high
pressure sodium lighting is recommended.
Step #3. Select type of luminaire, page 668.
VMV series Champ® luminaires are
recommended. For our example
VMVS3A150G pendant luminaire with RD70
dome reflector is selected.
Step #4. Calculation of number of luminaires
necessary.
(A) Compute CAVITIES of ceiling, room and
floor. HCC; HRC and HFC (see sketch on
worksheet).
(B) Obtain REFLECTANCE FACTORS (using
values on page 685) RC; RW and RF (see
sketch on worksheet).
(C) Compute CAVITY RATIOS for ceiling,
room and floor using Formula or Table IV,
page 684.
Formula
5 x HCC (L + W)
CCR =
LxW
RCR =

5 x HRC (L + W)

FCR =

5 x HFC (L + W)

LxW
LxW
(D) Determine Effective Ceiling Reflectance
from Table V, page 685. See work sheet for
values of RC, RW and CCR.
(E) Determine Coefficient of Utilization – from
CU table. For a VMVS3A150G luminaire,
applying an Effective Ceiling Cavity
Reflectance of 70; a wall reflectance of 50
and a room Cavity Ratio of 1.5 (all figures
applicable to our example), the CU (see CU
Table, page 733) is at mid-point between
.804 and .690, which is .747.
(F) Determine Light Loss Factor (LLF) – page
686.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:L:687))
CH0 0 L - 1 1

Job Requirement:
(See typical example at left)
Given Data:
(See typical assumptions at left)
Lamp Characteristics:
Type – High Pressure Sodium
Catalog # – VMVS3A150G with RD70 dome reflector
Lumens – 16,000
LLF – 0.77
No. of Footcandles Required: 50
Room: Length 80′

Width 40′

Height 15′

Cavities

Reflectance

Cavity Ratios: CCR 0.56

RCR 1.5

Effective Ceiling Cavity Reflectance:
Wall Reflectance:
CU:
Total Lumens Required:
No. of Luminaires:

CAN: 1-800-265-0502

FCR 0.75
72 (use 70)
50
.747
278,170
18 luminaires (see page 686)
Use 3 x 6 spacing

Copyright© 2006 Cooper Crouse-Hinds

687

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0688-2 Name: L-688

L

100:
DATE: JAN 19 2006

Time: 5:43:14 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Industrial Lighting Products

Figure 2 (continued)

5

Determine Placement of
Luminaires and Make Layout
Using the number of units as determined in Step 4 as a basic quantity
to work with, determine the number of lights per row and number of
rows required for the lighting system. Logic plays a part; for example: if
a room is 4 times as long as it is wide, you should have 4 times as
many luminaires in each row as there are number of rows. In any case,
the distance between the lighting units should not be greater than the
mounting height of the units above the floor. The distance between the
wall and first luminaire should not be more than 1⁄2 the spacing
between the units, and in situations where work is done immediately
adjacent to the wall, the distance should be reduced to 1⁄3 or 1⁄4 the
distance between units.

Four-Two system – equivalent to three units per bay or four per
bay where spacing allows.

In rooms that are divided by columns or beams, it is desirable to locate
the units symmetrically in the bays. The following layouts will serve as
a guide in planning such installations.
Important: Remember to observe the permissible spacing to
mounting height ratio or spacing criterion. If the number of luminaires
is insufficient to fulfill this requirement, recalculate using lower wattage
luminaires.
Four units per bay – if necessary could run in continuous rows
across room, or turned and run lengthwise with room.

Figure 2 Typical Placement
Incandescent/H.I.D., etc.

Fluorescent

One unit per bay – satisfactory only where the bay size is no
greater than the maximum allowable spacing – an unusual
condition.

Two units per bay – usually applicable only in narrow bays, where
the width is less than 2⁄3 the length.

688

STIBOINFO((CRH:66008com:L:688))
CH0 0 L - 1 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Grid pattern – usual condition dependent on room size and type of
work done there.

Four units per bay – this is the most common system for the
square bay of usual dimensions.

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0689-3 Name: L-689

100:
DATE: JAN 19 2006

Time: 5:43:15 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Industrial Lighting Products

L

Point-by-Point Method

EXAMPLE: Point-by-Point Method

(for use in highlighting –
see Step 4, page 683)

#1 Determine the footcandle value at floor
level immediately below a VDA22GRD with
200 Watt lamp and Dome reflector. Mounting
height of unit above floor is 12′.
#2 Using same unit as in #1, determine
footcandle value at floor level at a point 7 feet
away from luminaire.

Use this method to determine the footcandle
value at a point on a surface that is
illuminated by direct light from a luminaire or
luminaires.
When the light hits a point on the surface
head on (such as directly under a luminaire),
use formula ‘‘A’’, but when the light hits the
surface at an angle (such as between
luminaires) formula ‘‘B’’ must be used.

Figure 4/Methods of Measurement

Figure 6
Problem #1 – use Formula ‘‘A’’
CP
fc=
x LLF
d2

Fig. 5/Candlepower Distribution
Curve
Luminaire With Globe, Dome Reflector and
With or Without Guard
200 Watt, A-23 Incandescent

Formula ‘‘A’’
Footcandles = Candlepower
Light Loss
x factor
d2 (Distance)

715(a)
x 0.69(b) = 3.4 fc
(12)2
(a) Candlepower at 0° (from Light Distribution
Curve at left)

fc=

(b) Light loss factor from page 686

Candelas at 25 Feet

Formula ‘‘B’’
Footcandles ⍧ Candlepower x cosine of
angleΘ
d2 (Distance)

Light
x Loss
factor

Mid-zone
Angle
0
5
15
25
35
45
55
65
75
85
90
135
145

Without
Guard
715
722
736
764
793
715
615
531
197
42
14
13
28

Problem #2 – use Formula ‘‘B’’
CP x CosΘ
x LLF
fc=
d2

With
Guard
575
575
595
650
674
605
534
473
166
35
14
12
21

779(c) x 0.866
x 0.69 = 2.4 fc
(13.9)2
(c) Candlepower at 30° (from light
Distribution Table at left). Interpolate between
25° and 35°
fc=

Candlepower (at the proper angle) is found
from the Light Distribution Curve on the
luminaire catalog page. Distance ‘‘d’’ and
angle are found by measurement of a scaled
sketch of the lighting situation or through
trigonometric calculations.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:L:689))
CH0 0 L - 1 3

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

689

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0690-2 Name: Note Page-690

DATE: JAN 19 2006

Time: 5:43:16 PM Operator: JB

COLOR: CMYK

Notes Page

690

STIBOINFO((CRH:66008com::690))
CH0 3 A - 1 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0691-2 Name: 1L-691

100:
DATE: JAN 19 2006

Time: 5:44:25 PM Operator: RB

COLOR: CMYK

TCP: 15001

Incandescent Luminaires
Hazardous and Non-Hazardous

Typedriver Name: TS name csm no.: 100

1L

Description

Page No.

Application

692

Industrial Luminaires
Vaporgard TM Series
V Series
NDA CorroɀGard TM Series

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1L:691))
CH0 0 0 0 1 L

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

693-701
702-705
706, 707

691

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0692-3 Name: 1L-692

1L

100:
DATE: JAN 19 2006

Time: 5:44:25 PM Operator: JB

Enclosed and Gasketed
General Information

Application:

TCP: 15001

Table 500-3(d)
Identification Numbers.

Features:
ɀ Enclosed and gasketed luminaires that
accept incandescent lamps
ɀ Gaskets and glass globes help prevent dirt,
water and corrosive atmosphere from
entering the conduit system and corroding
the interior parts

Standard Materials:

Maximum
Temperature
Deg. C
Deg. F
450
842
300
572
280
536
260
500
230
446
215
419
200
392
180
356
165
329
160
320
135
275
120
248
100
212
85
185

Identification
Number
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

ɀ Luminaires-bodies, boxes and guards –
copper-free aluminum or Feraloy® iron alloy
ɀ Globes – heat-resistant glass or
polycarbonate
ɀ Reflectors – Krydon® fiberglass-reinforced
polyester

Standard Finishes:
ɀ Vaporgard TM – copper-free aluminum-epoxy
powder coat
ɀ V SERIES, – Feraloy iron alloy –
electrogalvanized and aluminum acrylic paint
ɀ Krydon material – luminaires: gray;
reflectors: high reflectance white

Size Ranges:
ɀ Include up to 300 watt, PS-30 lamp
ɀ 1⁄2⍯ to 11⁄4⍯ hubs

Certifications and
Compliances:
ɀ Weather resistant, NEMA 3, 3R
ɀ NEC/CEC: Class I, Division 2
ɀ UL Standard: 1598
ɀ CSA Standard: C22.2

692

STIBOINFO((CRH:66008com:1L:692))
CH0 0 1 L - 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Typedriver Name: TS name csm no.: 100

CI. I, Div. 2, Groups A, B, C, D
Weather Resistant

Incandescent Luminaires

Incandescent luminaires are used:
ɀ indoors or outdoors in industrial locations
ɀ in tunnels, building entrances or similar
locations, where moisture, dirt, chemicals,
vibration or rough usage are a problem
ɀ either mounted directly in the conduit
system or attached to cast outlet boxes, by
means of pendant, ceiling, wall bracket or
stanchion mountings

COLOR: CMYK

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0693-4 Name: 1L-693

100:
DATE: JAN 19 2006

Time: 5:44:26 PM Operator: RB

VAPORGARD TM Incandescent
Luminaires

Standard Materials:

Vaporgard series incandescent luminaires
are used:
ɀ indoors or outdoors in industrial locations
where enclosed and gasketed fixtures are
required
ɀ in tunnels, building entrances and similar
locations, where moisture, dirt, chemicals,
vibration or rough usage are a problem
ɀ for flush or surface mounting on ceiling or
wall; pendant or in conduit systems; with or
without a cast outlet box

ɀ Bodies and guards – copper-free aluminum
ɀ Globes
– heat and impact resistant
tempered glass
– colored glass nontempered (G55,
G56, G57, G58)
– plastic polycarbonate (G63, G65,
G67)
ɀ Reflectors – Krydon® fiberglass-reinforced
polyester

Features:

ɀ Bodies and guards – epoxy powder coat
ɀ Krydon material – high reflectance white

®

Krydon fiberglass-reinforced polyester
reflectors
ɀ Reflectance is equivalent to the finest
porcelain enamel
ɀ Cannot corrode – no enamel to chip and
rust
ɀ Ultraviolet inhibitors are incorporated in the
material to prevent discoloration and
brittleness

Typedriver Name: TS name csm no.: 100

1L

Standard Finishes:
Options:
The following options are available from the
factory by adding suffix to fixture Cat. No.:
Suffix to be
Description
Added to Cat.
No.:
ɀ Teflon coating on globe
for increased shatter
protection (G24 globe
200 watt series only)
S808
ɀ 250V nameplate for
export applications
/250
ɀ Plastic polycarbonate
globe
See page 696

Ratings (Electrical/Size):
ɀ Up to 300 watt, PS-30 medium base lamp
ɀ 1/2⍯ to 1-1/4⍯ hubs
ɀ 120V nameplate is standard – for NEC
compliance
ɀ 250V nameplate is optional. Supplied when
ordered with suffix: /250

Certifications and
Compliances:
ɀ Wet locations
ɀ NEC/CEC: Class I, Division 2
ɀ UL Standard: 1598
ɀ CSA Standard: C22.2 No. 9
ɀ UL/CSA Fixture Fitting

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1L:693))

TCP: 15001

Cl. I, Div. 2, Groups A,B,C,D
(All mounting except stanchion)
Wet Locations
NEMA 3,3R

Application:

ɀ Designed to exclude dirt, moisture and
corrosive vapors from the interior of the
luminaires and the conduit system
ɀ There are no screws to remove as the
shock-absorbing socket strap is keyhole
slotted and removes quickly for ease of
wiring
ɀ The glass globe-guard assembly is
installed and/or removed as a unit, making it
necessary to handle only one piece in
relamping
ɀ There are no crevices to accumulate a dirt
or dust buildup and fixture has an attractive
finish with a smooth, dust and dirt shedding
design
ɀ Configurated glass globe has vertical fluting
and stippled bottom which provides for more
even light distribution and glare elimination
ɀ For non-hazardous locations, shatterproof
plastic polycarbonate globes are available for
use with the 200 watt series.
ɀ Reversible offset socket mounting strap
permits use of various size lamps while
holding light center in same position for
maximum light output and efficiency
ɀ Shock absorbing medium base lamp
socket

CH0 0 1 L - 2

COLOR: CMYK

CAN: 1-800-265-0502

Class I, Division 2
Temperature Performance Data:
(Based on 40° C ambient)
Lamp
Watts

T-Number

Supply
Wire
°C

150
200
300

T2A
T2B
T2B

150°C
200°C
150° C

Copyright© 2006 Cooper Crouse-Hinds

693

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0694-2 Name: 1L-694

1L

100:
DATE: JAN 19 2006

Time: 5:44:27 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 2, Groups A,B,C,D
Wet Locations
NEMA 3,3R

VAPORGARD TM Incandescent
Luminaires
Enclosed and Gasketed

Luminaire Components
Catalog Nos.

Pendant Mount VDA Series

Thru-Feed VDC Series

Hub
Max Lamp
Size Series Size

Complete Cat.#
with globe/guard

Pendant
Body

Globe

Guard

1⁄2⍯

VDA15GP
VDA25GP

VDA15
VDA25

G54
G54

P50
P50

VDA35GP

VDA35

G54

P50

VDA12GP
VDA22GP

VDA12
VDA22

G24
G24

P21
P21

VDA32GP

VDA32

G24

P21

VDA13GP
VDA23GP

VDA13
VDA23

G34/G251 P22
G34/G251 P22

VDA33GP

VDA33

G34/G251 P22

Hub
Max Lamp
Size Series Size

Complete Cat.#
with globe/guard

Thru Feed
Body

Globe

Guard

1⁄2⍯

3⁄4⍯

150
150

1⍯

150

1⁄2⍯
3⁄4⍯

200
200

1⍯

200

1⁄2⍯
3⁄4⍯

300
300

1⍯

300

150 watt
A-21
200 watt
A-23
300 watt
PS-25 & PS-30

150
150

150 watt
A-21

VDC15GP
VDC25GP

VDC15
VDC25

G54
G54

P50
P50

200
200

200 watt
A-23

VDC12GP
VDC22GP

VDC12
VDC22

G24
G24

P21
P21

300
300

300 watt
PS-25 & PS-30

VDC13GP
VDC23GP

VDC13
VDC23

G34/G251 P22
G34/G251 P22

Hub
Max Lamp
Size Series Size

Complete Cat.#
with globe/guard

Lamp
Socket
Body

Globe

Guard

1⁄2⍯

150

150 watt
A-21

VXH15GP

VXH15

G54

P50

1⁄2⍯

200

VXH12GP

VXH12

G24

P21

1⁄2⍯

300

200 watt
A-23
300 watt
PS-25 & PS-30

VXH13GP

VXH13

G34/G251 P22

Hub
Size

Max Lamp
Series Size

Complete Cat.#
with globe/guard

Lamp
Socket
Body

Globe

Guard

Junction
Box

1⁄2⍯

150
150

150 watt
A-21

VXHF15GP
VXHF25GP

VXH15
VXH15

G54
G54

P50
P50

VXF10
VXF20

200
200

200 watt
A-23

VXHF12GP
VXHF22GP

VXH12
VXH12

G24
G24

P21
P21

VXF10
VXF20

300
300

300 watt
PS-25 & PS-30

VXHF23GP
VXHF23GP

VXH13
VXH13

G54/G251 P22
G34/G251 P22

VXF20
VXF20

3⁄4⍯
1⁄2⍯
3⁄4⍯
1⁄2⍯
3⁄4⍯

Ceiling Mount for
Recessed 4⍯ Round
Box - VXH Series

Ceiling Mount with
Junction Box VXHF Series

3⁄4⍯
1⁄2⍯
3⁄4⍯
1⁄2⍯
3⁄4⍯

 – available with Lightning Service TM
See Section G for complete details

694

STIBOINFO((CRH:66008com:1L:694))
CH0 0 1 L - 3

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0695-2 Name: 1L-695

100:
DATE: JAN 19 2006

Time: 5:44:28 PM Operator: JB

VAPORGARD TM Incandescent
Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 2, Groups A,B,C,D
Wet Locations
NEMA 3,3R

1L

Enclosed and Gasketed

Wall Mount VXHT Series

Luminaire Components
Catalog Nos.

Hub
Max Lamp
Size Series Size

Complete Cat.#
with globe/guard

Wall
Bracket
Mounting
Module Body

1⁄2⍯
3⁄4⍯
1⁄2⍯
3⁄4⍯
1⁄2⍯
3⁄4⍯

Wall Mount Adapter Kit

Globe

Guard

150
150

150 watt
A-21

VXHT15GP
VXHT25GP

VXT10
VXT20

VXH15
VXH15

G54
G54

P50
P50

200
200

200 watt
A-23

VXHT12GP
VXHT22GP

VXT10
VXT20

VXH12
VXH12

G24
G24

P21
P21

300
300

300 watt
VXHT13GP
PS-25 & PS-30 VXHT23GP

VXT10
VXT20

VXH13
VXH13

G34/G251 P22
G34/G251 P22

Mounts wall mount VXHT Series
to a 4⍯ Round Box.
Cat. No. VXT-K1

Wall Mount with
Junction Box
VXHBF Series

Hub
Max Lamp
Size Series Size

Complete Cat.#
with globe/guard

Wall
Bracket
Mounting
Module Body

1⁄2⍯
3⁄4⍯
1⁄2⍯
3⁄4⍯
1⁄2⍯
3⁄4⍯

Stanchion Mount VXHA Series

Junction
Guard Box

150
150

150 watt
A-21

VXHBF15GP
VXHBF25GP

VXT10
VXT20

VXH15
VXH15

G54
G54

P50
P50

VXF10
VXF20

200
200

200 watt
A-23

VXHBF12GP
VXHBF22GP

VXT10
VXT20

VXH12
VXH12

G24
G24

P21
P21

VXF10
VXF20

300
300

300 watt
VXHBF13GP
PS-25 & PS-30 VXHBF23GP

VXT10
VXT20

VXH13
VXH13

G34/G251 P22
G34/G251 P22

VXF10
VXF20

Complete Cat.#
with globe/guard

Stanchion
Mounting
Module Body

Globe

Guard

VXHA45GP

VXA4

VXH15

G54

P50

200 watt
VXHA42GP
A-23
300 watt
VXHA43GP
PS-25 & PS-30

VXA4

VXH12

G24

P21

VXA4

VXH13

G34/G251 P22

Hub
Max Lamp
Size Series Size
1

Globe

1⁄4⍯

1 1⁄4⍯
1 1⁄4⍯

150 watt
A-21

 – available with Lightning Service TM
See Section G for complete details

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1L:695))
CH0 0 1 L - 3

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

695

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0696-7 Name: 1L-696

DATE: JAN 19 2006

Time: 5:44:30 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

VAPORGARD TM Incandescent
Luminaires

1L

Parts and Accessories

Medium Base
Lamp Receptacle
with Strap

Plastic Globes 1

Globes† and Guards

Shock Absorbing
Cat. #
V84
150 and 200W
globe
300W globe

Reflectors

Color
Clear
(heatresisting)
Green
Blue
Red
Amber

Dome

Maximum Lamp Size
150 Watt, 200 Watt, 300 Watt,
A-21
A-23, A-25, PS-25
PS-25
PS-30‡

Application:

Cat. #

Cat. #

Features:

G54
G55*
G56*
G57*
G58*

G24ɍ
G25
G26
G27
G28

Cat. #
G34 
{G251

30° Angle
Max.
Lamp
Size
150 watt,
A-21
200 watt,
A-23, A-25,
PS-25 and
300 watt,
PS-30

Dome
Cat. #
RD64

30° Angle
Cat. #
RA64

RD71

RA71

Shatterproof
polycarbonate
plastic globe**

Guard P50
and P21
Guard P22
Guards for Glass Globes (Not for use with
plastic globes)
Cat. #
Maximum Lamp Size
P50 
150 watt, A-21
P21 
200 watt, A-23, A-25, PS-25
P22 
300 watt, PS-30 (with G251 only)

For use in:
ɀ food processing plants and canneries,
dairies, breweries and bakeries
ɀ emergency lighting
ɀ Shatterproof, which precludes
contamination of food products with broken
particles of glass.
ɀ Designed to comply with U.S. Dept. of
Agriculture specification for food processing
plants.
ɀ Provides protection against vandalism, with
resultant lower replacement and
maintenance costs.
ɀ Particularly adaptable for use on
emergency police or fire alarm boxes.
ɀ Same size as G24 series glass globes.
Existing installations can be changed to
plastic globes simply by replacing globe.
ɀ For use with 200 watt series luminaires
such as VDA22, etc.
ɀ For use without guard.
Max. Wattage,
Color
Lamp Size
Cat. #
Natural
200 watt, A-23
G63 
Green
200 watt, A-23
G65
Red
200 watt, A-23
G67
Note: Polycarbonate globes for nonhazardous locations only.

Mounting Adapter Kit

ɀ Allows for the mounting of non-CrouseHinds outlet boxes to the VXT20 wall mount
bracket and VXH ceiling mount bracket
Cat. #
VXT-K1

VXFT – 5 Hubs, 4 Plugs
Hub
Size
Cat. #
1⁄2
VXFT10
3⁄4
VXFT20
For use when rear wiring entry is required.
Use in lieu of VXF10 or VXF20.

VXT-K1
ɍ G24 is available with a TEFLON coating for increased shatter protection by
adding suffix S808.
* With G55, G56, G57, G58 color globes, maximum lamp size is 60 watt for outdoor
applications.
** Prior to wash-down, globes must be cool.
† All glass globes are configured type, having fluted side and stippled bottom.
‡ Globe G251 required when guard P22 is used. Use globe G34 when guard is not
used.
1 Lamp must be mounted in vertical position base up to 45°C (stanchion) only.
®

 – available with Lightning Service TM
See Section G for complete details

696

STIBOINFO((CRH:66008com:1L:696))
CH0 0 1 L - 7

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0697-9 Name: 1L-697

100:
DATE: JAN 19 2006

Time: 5:44:32 PM Operator: RB

VAPORGARD TM Series
Incandescent
Luminaires

COLOR: CMYK

TCP: 15001

Family Tree

Typedriver Name: TS name csm no.: 100

1L

 – available with Lightning Service TMSee Section G for complete details

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1L:697))
CH0 1 L - 1 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

697

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0698-1 Name: 1L-698

1L

100:
DATE: JAN 19 2006

Time: 5:44:33 PM Operator: JB

VAPORGARD TM Incandescent
Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

Luminaire With Globe, 30° Angle Reflector and With
or Without Guard

Luminaire VXHA45GPRA
Lamp: 150W/A-21
Total Bare Lamp Lumens: 2850
Total
Lumens Eff. %
With
Guard

1490

52.3

Without
Guard

1881

66.0

Lamp: 100W/A-21 through 200W/A-23
Total Bare Lamp Lumens: 4000
NOTE: All data provided is for 200W/A-23 incandescent lamp. Use
following candlepower/lumen multipliers for other lamp sizes:
100W 0.42; 150W 0.7

Measurements taken from A-A′ plane.

Measurements taken from A-A′ plane.

Luminaire VXHA42GPRA
Lamp: 300W/PS-30
Total Bare Lamp Lumens: 6300
Total
Lumens Eff. %
With
Guard
Without
Guard

3630

57.6

4271

67.8

Lamp
Size
100W
150W
200W/A-23
200W/PS-25

Without Guard
Total
Lumens Eff. %
1141
1890
2700
67.5
2174

With Guard
Total
Lumens Eff. %
949
1582
2260
56.5
1819

Luminaire With Globe, 30° Angle Reflector and With
or Without Guard
Lamp: 300W/PS-30
Total Bare Lamp Lumens: 6000
Total
Lumens Eff. %
With
Guard
Without
Guard

Measurements taken from A-A′ plane.

Measurements taken from A-A′ plane.

698

STIBOINFO((CRH:66008com:1L:698))
CH0 0 1 L - 8

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

3360

56.0

3954

65.9

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0699-2 Name: 1L-699

DATE: JAN 19 2006

Time: 5:44:34 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

VAPORGARD TM Incandescent
Luminaires

1L

Lamp: 100W/A-21 through 200W/PS-25
Total Bare Lamp Lumens: 4000
To determine number and placement of luminaires see Lighting Selector Guide, pages 665 to
689.
NOTE: All data provided is for 200W/A-23 incandescent lamp. Use following candela/lumen
multipliers for other lamp sizes: 100W 0.42;
150W 0.7;
200W/PS-25 0.82

Luminaire With Globe and With or
Without Guard

Luminaire With Globe, Dome Reflector and With
or Without Guard

Example: Zonal Lumens for
200W/A-23 lamp with guard
for 0-40° is 272 Zonal
Lumens for 150W lamp with
guard for 0-40° is 272 × 0.7
⍧ 190.

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.654
.549
.471
80
30
.608
.486
.400
10
.567
.432
.345
50
.603
.506
.434
70
30
.563
.449
.370
10
.523
.401
.320
50
.509
.424
.363
50
30
.477
.380
.313
10
.449
.341
.271
50
.422
.349
.297
30
30
.399
.315
.259
10
.376
.285
.225
50
.343
.280
.237
10
30
.324
.253
.206
10
.307
.230
.180

4
.407
.333
.277
.375
.309
.257
.312
.260
.218
.255
.214
.180
.202
.170
.143

5
.353
.282
.228
.326
.260
.211
.273
.220
.179
.223
.180
.147
.176
.142
.115

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.604
.522
.454
80
30
.576
.480
.404
10
.552
.444
.364
50
.591
.512
.445
70
30
.565
.472
.398
10
.543
.440
.361
50
.564
.490
.428
50
30
.544
.457
.387
10
.526
.428
.354
50
.541
.470
.411
30
30
.525
.444
.377
10
.509
.419
.348
50
.521
.452
.396
10
30
.507
.429
.367
10
.494
.409
.342

4
.395
.340
.298
.387
.336
.296
.372
.327
.292
.358
.319
.288
.345
.311
.283

5
.347
.290
.248
.339
.286
.246
.327
.280
.245
.315
.273
.241
.304
.268
.238

% Reflectance
Eff Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10

9
.226
.162
.118
.208
.150
.110
.175
.126
.092
.143
.103
.075
.114
.080
.057

10
.201
.140
.100
.185
.130
.093
.156
.109
.077
.128
.088
.061
.101
.068
.045

Reflectance
Eff Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10

9
.222
.170
.135
.219
.168
.135
.211
.166
.134
.204
.162
.133
.198
.159
.131

10
.193
.142
.110
.189
.142
.110
.184
.139
.109
.178
.136
.107
.173
.134
.106

Room Cavity Ratio
6
7
8
.315
.279
.249
.244
.210
.183
.193
.164
.137
.289
.257
.230
.225
.194
.170
.177
.150
.127
.242
.215
.192
.189
.163
.143
.150
.126
.106
.198
.175
.158
.155
.134
.116
.123
.102
.086
.157
.140
.124
.122
.106
.091
.096
.080
.066

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1L:699))
CH0 0 1 L - 9

Example: Zonal Lumens for
200W/A-23 lamp with guard
for 0-40° is 948 Zonal
Lumens for 150W lamp with
guard for 0-40° is 948 × 0.7
⍧ 664.

CAN: 1-800-265-0502

Room Cavity Ratio
6
7
8
.309
.274
.244
.253
.220
.192
.214
.184
.155
.303
.270
.241
.250
.217
.191
.211
.181
.154
.291
.260
.232
.245
.212
.186
.209
.179
.153
.281
.250
.225
.239
.209
.182
.207
.177
.152
.272
.243
.217
.234
.205
.179
.205
.175
.150

Copyright© 2006 Cooper Crouse-Hinds

699

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0700-2 Name: 1L-700

1L

DATE: JAN 19 2006

Time: 5:44:35 PM Operator: RB

VAPORGARD TM Incandescent
Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

Lamp: 300W/PS-30
Total Bare Lamp Lumens: 6000
To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to
689.

Luminaire With Globe Only

Luminaire With Globe and Dome Reflector

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.692
.582
.499
80
30
.644
.515
.425
10
.602
.459
.367
50
.636
.534
.458
70
30
.594
.475
.392
10
.552
.425
.339
50
.532
.444
.380
50
30
.500
.398
.328
10
.470
.358
.285
50
.437
.362
.308
30
30
.412
.326
.268
10
.389
.295
.234
50
.350
.285
.241
10
30
.331
.258
.210
10
.313
.235
.183

4
.431
.354
.295
.396
.327
.273
.327
.272
.229
.264
.222
.186
.205
.172
.145

5
.373
.300
.243
.345
.276
.223
.286
.230
.188
.230
.186
.152
.179
.144
.116

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.766
.671
.587
80
30
.734
.621
.528
10
.706
.579
.482
50
.750
.657
.577
70
30
.720
.610
.521
10
.694
.573
.477
50
.717
.630
.555
50
30
.693
.592
.507
10
.672
.558
.468
50
.688
.606
.535
30
30
.670
.575
.494
10
.651
.546
.460
50
.663
.584
.516
10
30
.647
.557
.482
10
.632
.534
.452

4
.514
.448
.398
.505
.444
.395
.485
.432
.390
.468
.422
.385
.452
.412
.379

5
.454
.385
.334
.443
.380
.332
.429
.372
.329
.414
.364
.325
.400
.357
.321

% Reflectance
Eff Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10

9
.238
.170
.125
.219
.157
.115
.181
.131
.095
.146
.105
.075
.114
.080
.055

10
.212
.147
.105
.194
.136
.097
.162
.113
.079
.130
.090
.061
.101
.067
.044

% Reflectance
Eff Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10

9
.293
.229
.185
.288
.227
.185
.279
.223
.184
.270
.218
.182
.262
.215
.180

10
.254
.191
.151
.249
.191
.151
.243
.187
.150
.235
.184
.148
.229
.181
.146

700

STIBOINFO((CRH:66008com:1L:700))
CH0 1 L - 1 0

Room Cavity Ratio
6
7
8
.333
.295
.263
.258
.223
.194
.205
.173
.145
.305
.271
.241
.238
.204
.178
.188
.158
.133
.253
.224
.200
.198
.170
.148
.157
.132
.110
.204
.180
.162
.160
.138
.119
.127
.105
.088
.158
.141
.124
.123
.106
.091
.096
.079
.066

US: 1-866-764-5454

CAN: 1-800-265-0502

Room Cavity Ratio
6
7
8
.404
.360
.322
.337
.294
.258
.289
.250
.212
.397
.354
.317
.333
.290
.256
.285
.246
.211
.383
.342
.306
.326
.284
.250
.283
.244
.209
.371
.330
.297
.320
.280
.245
.281
.241
.208
.359
.322
.288
.313
.275
.241
.277
.239
.206

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0701-1 Name: 1L-701

100:
DATE: JAN 19 2006

Time: 5:44:36 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

VAPORGARD TM Incandescent
Luminaires

1L

Dimensions

a
b
c
d
e
f
g
h
j

150 watt,
A-21
127⁄8
111⁄8
53⁄8
313⁄16
87⁄16
12
813⁄16
9
41⁄2

200 watt,
PS-25
167⁄8
145⁄8
6
4
91⁄8
14
101⁄2
1013⁄16
611⁄16

300 watt,
PS-30
167⁄8
145⁄8
6
4
91⁄8
14
12
131⁄8
611⁄16

VDA Series

VDC Series

VXH and VXHF Series
(omit box for VXF Series)

VXHT and VXHBF Series
(NOTE: Omit box for VXHB series)
Max. Lamp Size
150 watt, A-21

a
53⁄8

200 watt, A-23, A-25, PS-25
and 300 watt, PS-30
6

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1L:701))
CH0 1 L - 1 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

701

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0702-2 Name: 1L-702

DATE: JAN 19 2006

Time: 5:44:37 PM Operator: RB

V-Series Incandescent
Luminaires

1L

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Wet Locations
NEMA 3,3R

Enclosed and Gasketed

Application:

Standard Materials:

V-Series incandescent luminaires are used:
ɀ indoors or outdoors in industrial locations
where enclosed and gasketed fixtures are
required
ɀ in tunnels, building entrances and similar
locations, where moisture, dirt, chemicals,
vibration or rough usage are a problem
ɀ for flush or surface mounting on ceiling or
wall, with or without a cast outlet box,
pendant or in conduit systems

ɀ Bodies – Feraloy® iron alloy
ɀ Guards – copper-free aluminum
ɀ Globes – glass
ɀ Reflectors – Krydon® fiberglass-reinforced
polyester material reflectors

Certifications and
Compliances:
ɀ Wet locations
ɀ NEMA: 3, 3R
ɀ UL Standard: 1598

Standard Finishes:
ɀ Feraloy iron alloy – electrogalvanized and
aluminum acrylic paint
ɀ Copper-free aluminum – natural
ɀ Krydon® material – high reflectance white

Features:
ɀ Designed to exclude dirt, moisture and
corrosive vapors from the interior of the
fixtures and the conduit system.
ɀ Several body styles provide a wide variety
of mountings, while all use the same globes,
guards and optional accessories.
ɀ Rugged and corrosion resistant.

Size Ranges:
ɀ 3⁄4 hubs
ɀ Maximum wattage lamp:
- Glass globes 150W, A23
- Polycarbonate 75W, A33

Options:
Description
Corro-free TM epoxy
powder coat

Suffix
S752

plastic polycarbonate
globe

Order separately.
See below

VDA

VC

VG

VJ

VD

Description
With plain globe
and guard

Cat. #
VDA2759

Cat. #
VC2759

Cat. #
VG2759

Cat. #
VJ2759

Cat. #
VD2759

Without globe and
guard

VDA275

VC275

VG275

VJ275

VD275

Glass Globes

Guard For
Glass Globes

Polycarbonate Globes
Application:
Polycarbonate globes are used:
ɀ in food processing plants, canneries,
dairies, breweries and bakeries
ɀ in emergency lighting
ɀ emergency police and fire alarm boxes

Features:
ɀ Polycarbonate globes are shatterproof,
preclude contamination of food products
with broken particles of glass.
ɀ Comply with U.S. Dept. of Agriculture
specification for food processing plants.

V63
Color
Clear (heat
resisting)
Green
Blue
Red
Amber

702

STIBOINFO((CRH:66008com:1L:702))
CH0 1 L - 1 2

Cat. #
V63
VN72
VN73
VN75
VN76

V911
Globe
Size
63⁄4⍯

Cat. #
V911

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

V470
Color
Natural
Red

Cat. #
V470
V475

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0703-3 Name: 1L-703

DATE: JAN 19 2006

Time: 5:44:39 PM Operator: RB

COLOR: CMYK

TCP: 15001

Incandescent Luminaires

Typedriver Name: TS name csm no.: 100

1L

Accessories and Parts For V-Series

Dome

Receptacles (medium base)
Cat. #
V46

Angle

Gasket
Cat. #
GASK213

Reflectors
Krydon® – fiberglass-reinforced polyester
(Must be used with V 911 Guard)
Lamp
Size
50-150W
Lamp
Size
50-150W

Dome
Dia.
Cat. #
12⍯
RD60
30° Angle
Dia.
Cat. #
12⍯
RA60

NOTE: Angle reflector cannot always be used
with bracket style fixtures. Check distance
from mounting surface to center of body
against reflector size to determine if reflector
will fit.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1L:703))
CH0 1 L - 1 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

703

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0704-1 Name: 1L-704

100:
DATE: JAN 19 2006

Time: 5:44:40 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

V-Series Incandescent
Luminaires

1L

Enclosed and Gasketed
Dimensions
VC

Hub
Size
1⁄2
3⁄4

VDA

a
7⁄8
7⁄8

c
311⁄16
311⁄16

d
4
4

h
63⁄16
63⁄16

VD

k
49⁄16
49⁄16

VG

Hub
Size
1⁄2
3⁄4

a
415⁄16
415⁄16

b
43⁄16
43⁄16

c
515⁄16
63⁄16

g
21⁄2
23⁄4

h
63⁄16
63⁄16

k
49⁄16
49⁄16

b
113⁄16
115⁄16

c
47⁄8
47⁄8

d
3⁄8

e
53⁄8
53⁄8

h
63⁄16
63⁄16

k
49⁄16
49⁄16

VJ

c
47⁄8
47⁄8

704

STIBOINFO((CRH:66008com:1L:704))
CH0 1 L - 1 6

Hub
Size
1⁄2
3⁄4

h
63⁄16
63⁄16

Hub
Size
1⁄2
3⁄4

k
49⁄16
49⁄16

US: 1-866-764-5454

CAN: 1-800-265-0502

3⁄8

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0705-2 Name: 1L-705

DATE: JAN 19 2006

Time: 5:44:41 PM Operator: RB

COLOR: CMYK

TCP: 15001

Photometric Data

V-Series Incandescent
Luminaires

Typedriver Name: TS name csm no.: 100

1L

Enclosed and Gasketed

Luminaires V-Series
Lamp: 150W/A23 Clear
Total Bare Lamp Lumens: 2800
To determine number and placement of fixtures, see Lighting Selector
Guide pages 665 to 689.
Zonal Lumens
NOTE: All data provided is
Without With
for 150W incandescent
Zone Guard Guard
lamp. Use following
0-10
29
19
10-20
67
60
candela/lumen multipliers
20-30
109
60
for the other lamp sizes:
30-40
127
113
40-50
175
168
100W – 0.61
50-60
218
117
60-70
246
250
Example: Zonal lumens
70-80
228
232
80-90
223
65
for 150W lamp for 0-40°
90-100 209
218
with guard is 252.
100-110 210
218
110-120 210
120-130 194
130-140 164
140-150
87
150-160
3
Total
2499

216
72
165
58
8
2039

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall
50
80
30
10

Room Cavity Ratio
1
2
3
.659
.558
.479
.623
.504
.417
.591
.458
.367

4
.416
.349
.298

5
.361
.298
.248

70

50
30
10

.609
.577
.545

.515
.466
.426

.442
.386
.342

.384
.324
.278

.336
.275
.230

50

50
30
10

.515
.491
.469

.434
.397
.364

.372
.328
.293

.321
.274
.238

.282
.234
.197

30

50
30
10

.429
.411
.395

.359
.332
.307

.307
.274
.245

.264
.228
.198

.232
.194
.165

10

50
30
10

.350
.337
.325

.290
.269
.251

.246
.221
.199

.211
.183
.160

.185
.156
.132

Room Cavity Ratio
6
7
8
.325
.290
.261
.259
.227
.199
.212
.183
.157

9
.236
.176
.136

10
.211
.153
.116

% Reflectance
Eff. Ceil.
Wall
50
80
30
10
70

50
30
10

.299
.240
.197

.268
.210
.170

.241
.186
.146

.219
.164
.127

.194
.143
.108

50

50
30
10

.252
.205
.169

.226
.178
.145

.203
.158
.125

.185
.140
.109

.165
.122
.092

30

50
30
10

.208
.170
.141

.186
.149
.121

.169
.131
.105

.153
.117
.091

.137
.101
.076

10

50
30
10

.167
.136
.114

.151
.121
.098

.135
.106
.084

.124
.094
.073

.110
.081
.060

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1L:705))
CH0 1 L - 1 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

705

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0706-1 Name: 1L-706

1L

DATE: JAN 19 2006

Time: 5:44:42 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 2, Groups A,B,C,D
Corrosive
Wet Locations
NEMA 3,3R,4,4X

NDA CorroɀGard TM CorrosionResistant Incandescent
Luminaires

NDA Series Ordering
Information

Application:

CorroɀGard TM NDA series Luminaires made
of Krydon® fiberglass-reinforced polyester are
used to provide incandescent lighting:
ɀ indoors or outdoors in industrial wet or dirty
locations and where corrosion is a problem
ɀ in marine applications, above and below
deck, where salt spray corrosion shortens
fixture life
ɀ in food and beverage industries where
frequent wash-downs are necessary
ɀ for walkways, bridges, tunnels, security
lighting, cold storage facilities, garages, coal
handling areas, shipboard, processing
plants, and nuclear generating plant
containment areas

For Pendant Mounting

Hub
Size
3⁄4⍯

Max.
Lamp
Size
300W
PS-25
Med.
Base
120V

Body
Only
Cat. #
NDA22

Globe
Only
Cat. #
G24

Temperature Performance Data:

Features:
ɀ Luminaire is molded Krydon for excellent
corrosion, heat, and impact resistance.
ɀ Accommodates all popular incandescent
lamps up to 300W, PS-25.
ɀ Attractive modern design and color
complement other CorroɀGard products.
ɀ Weighs only 81⁄2 lbs. complete with lamp
and globe.
ɀ Medium screw base porcelain lamp socket
has a vibration absorbing mounting bracket.
ɀ All joints are gasketed to ensure
watertightness.
ɀ Configured glass globe reduces glare.
ɀ CorroɀGard reflectors made of Krydon®
reflect light better than porcelainized steel; do
not yellow or discolor with age; cannot chip,
peel, rust or dent.
®

Certifications and
Compliances:
ɀ UL Standard: 1598
ɀ Wet Locations
ɀ Suitable for 40°C ambient temperature

(based on 40°C ambient)
Max.
Lamp
Size
T-Number
300W
T2A
(Note: Fixtures are not marked with T-Number.)

Dimensions

Standard Materials:
ɀ Bodies and reflectors – Krydon® fiberglassreinforced polyester material
ɀ Globes – configured heat-resistant glass

Standard Finishes:
ɀ Bodies – natural
ɀ Reflectors – natural, high reflectance white

Options:
ɀ TEFLON® coating on G24 globe for
increased shatter protection. . . . . . . add suffix
S808.

Accessories & Parts
Globe

Replacement Lamp
Receptacles with Strap

Reflectors
(Order separately)

Shock Absorbing

Guard

Dome

Cat No. NV84

Color
Clear (heat resisting)
Green
Blue
Red
Amber

706

STIBOINFO((CRH:66008com:1L:706))
CH0 1 L - 2 0

Body
With
Globe‡
Cat. #
NDA22G

Cat. #
G24
G25
G26
G27
G28

Cat. #
P21

30° Angle

Type
Dome
30° Angle
US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Cat. #
RD725 (RD75)
RA725 (RA75)

Supply
Wire (°C)
150°C

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0707-2 Name: 1L-707

DATE: JAN 19 2006

Time: 5:44:43 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

NDA CorroɀGard TM CorrosionResistant Incandescent
Luminaires

1L

Lamp: 200W/PS-25
To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to
689.
NOTE: All data provided is for incandescent with 200W/PS-25 lamp. See Multipliers for other
wattages and lamp types.

Luminaire With Globe

Luminaire With Globe and
Dome Reflector

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%
% Reflectance Room Cavity Ratio
Eff. Ceil.Wall 1
2
3
4
50
.762 .651 .565 .494
80
30
.715 .585 .491 .416
10
.673 .529 .433 .357

Effective Floor Cavity Reflectance 20%
% Reflectance Room Cavity Ratio
Eff. Ceil.Wall 1
2
3
4
50
.809 .703 .615 .541
80
30
.773 .647 .550 .470
10
.742 .601 .499 .416

5
.433
.358
.300

CANDLES AT 25 FT. IN PLANE
A-A’ WITHOUT GUARD
DEGREES FRONT BACK
0
630
5
646
619
10
672
577
15
677
539
20
677
498
25
677
465
30
677
422
35
677
388
40
640
338
45
630
278
50
630
89
55
625
24
60
583
5
65
551
70
525
75
461
80
422
85
385
90
346
95
310
100
273
105
207
110
68
115
24
120
5
125
130

5
.481
.408
.354

Total
Lumens
2595

Eff. %
80.6

70

50
30
10

.708
.667
.626

.605
.546
.496

.526
.460
.407

.461
.390
.336

.406
.335
.282

70

50
30
10

.791
.758
.729

.688
.636
.595

.604
.542
.494

.531
.465
.413

.470
.403
.315

50

50
30
10

.608
.576
.547

.519
.473
.432

.452
.399
.356

.395
.339
.295

.292
.250
.248

50

50
30
10

.756
.729
.706

.659
.617
.579

.580
.528
.485

.510
.453
.408

.455
.395
.349

Multipliers for Other Lamps

30

50
30
10

.516
.492
.469

.439
.404
.372

.382
.342
.307

.335
.290
.254

.297
.250
.215

30

50
30
10

.726
.705
.684

.634
.599
.566

.558
.514
.477

.492
.442
.402

.439
.385
.344

Photometric data was developed using a 200
watt/PS-25 inside frosted incandescent lamp (3,220
lumens). For other incandescent watts/lamp size,
use the following conversion factors (multipliers):

10

50
30
10

.433
.413
.396

.366
.339
.315

.319
.287
.259

.279
.244
.215

.247
.211
.181

10

50
30
10

.699
.663
.580

.610
.580
.553

.539
.501
.468

.475
.431
.396

.424
.378
.340

0

0

.354

.277

.226

.184

.154

0

0

.647

.536

.451

% Reflectance
Eff. Ceil.Wall
50
80
30
10

.378

.323

Room Cavity Ratio
6
7
8
.431 .386 .347
.360 .317 .280
.309 .269 .231

9
.317
.250
.204

10
.277
.211
.169

70

50
30
10

.423
.356
.305

.380
.312
.265

.342
.277
.231

.312
.247
.204

.272
.211
.169

.205
.153
.117

50

50
30
10

.408
.348
.303

.368
.305
.263

.331
.272
.229

.302
.243
.202

.265
.207
.167

.197
.152
.121

.175
.131
.100

30

50
30
10

.396
.342
.300

.355
.301
.260

.321
.266
.227

.294
.238
.201

.257
.203
.165

.180
.144
.116

.166
.129
.102

.147
.110
.084

10

50
30
10

.383
.334
.297

.346
.295
.258

.311
.262
.225

.285
.235
.199

.250
.200
.163

.096

.084

.068

0

0

.281

.243

.210

.184

.150

Room Cavity Ratio
6
7
8
.389 .348 .312
.312 .273 .240
.258 .222 .190

9
.284
.214
.166

10
.253
.185
.141

70

50
30
10

.363
.293
.242

.324
.256
.208

.291
.226
.179

.266
.201
.157

.236
.175
.133

50

50
30
10

.312
.256
.213

.280
.223
.183

.252
.198
.158

.230
.177
.139

30

50
30
10

.266
.220
.185

.238
.193
.158

.216
.170
.137

10

50
30
10

.223
.185
.156

.201
.163
.135

0

0

.132

.112

% Reflectance
Eff. Ceil.Wall
50
80
30
10

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1L:707))
CH0 1 L - 1 5

Luminaire With Globe and
30° Angle Reflector

CAN: 1-800-265-0502

Watts
100
100

Lamp Size
A-19
A-21

Lamp
Lumens
1750
1690

Conversion
Factor
.54
.52

150
150

A-21
PS-25

2880
2680

.89
.83

200

A-23

4010

1.25

300

PS-25

6360

1.98

Example: Zonal lumens for 200W/PS-25 luminaire
with globe and dome reflector for 30-40° is 389.
Zonal lumens for 100W/A-21 luminaire with globe
and dome reflector for 30-40° is 389 × .52 ⍧ 202.

Copyright© 2006 Cooper Crouse-Hinds

707

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0708-2 Name: Note Page-708

DATE: JAN 19 2006

Time: 5:44:44 PM Operator: TB

COLOR: CMYK

Notes Page

708

STIBOINFO((CRH:66008com::708))
CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0709-3 Name: 2L-709

100:
DATE: JAN 19 2006

Time: 5:44:45 PM Operator: RB

COLOR: CMYK

TCP: 15001

Incandescent Luminaires
Hazardous

Typedriver Name: TS name csm no.: 100

2L

Description

Page No.

Application/Selection

Page 710

Class I Hazardous Area Luminaires
EVI Series
Groups C, D
EV Series
Groups A, B, C, D

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2L:709))
CH0 0 0 0 2 L

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

711-719
720

709

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0710-3 Name: 2L-710

2L

100:
DATE: JAN 19 2006

Time: 5:45:48 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Incandescent Luminaires
Hazardous
Application and Selection

Application:
ɀ For use in areas made hazardous by
presence of flammable vapors, gases, or
dusts
ɀ For indoor or outdoor use. For general area
or spot lighting

Considerations for
Selection:
Environmental:
ɀ What is the hazardous area classification
(NEC)/(CEC) of the location in which the
luminaires will be installed?
Lighting levels required:
ɀ What wattage fixture(s) will provide the
desired light level? (See Lighting Selector
Guide, pages 665 through 689, to determine
number and location of luminaires required.)
Physical arrangement:
ɀ Type of luminaire mounting needed

Product Selection:
Two product families are included in Section
2L as follows:
ɀ EVI models suitable for use in Class I,
Groups C, D, and Class II, Groups E, F and G
locations. These luminaires may be ordered
with a wide variety of reflector styles and
mounting arrangements to provide the
required light distribution, depending on
application, mounting height and lamp size.
Check individual catalog pages for specific
hazardous location suitabilities of each
luminaire. Models are available for lamp sizes
100 watt, A-19 to 500 watt, PS-40.
ɀ EV Models suitable for use in Class 1,
Groups A, B, C, D locations. These luminaires
may be ordered with a wide variety of
reflector styles and arrangements to provide
the required light distribution, depending on
application, mounting height and lamp size.
Check individual catalog pages for specific
hazardous location suitabilities of each
luminaire. Models are available for lamp size
300 watt PS35 mogul base.

Table 500-3(d)
Identification Numbers.
Maximum
Temperature
Deg. C
Deg. F
450
842
300
572
280
536
260
500
230
446
215
419
200
392
180
356
165
329
160
320
135
275
120
248
100
212
85
185

710

STIBOINFO((CRH:66008com:2L:710))
CH0 0 2 L - 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Identification
Number
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0711-12 Name: 2L-711

DATE: JAN 19 2006

Time: 5:45:49 PM Operator: RB

EVI Series Explosionproof
Incandescent Luminaires
Factory Sealed
100-500W Medium and Mogul Base
Application:

Features:

ɀ Ambient suitability to 65°C.
ɀ Standard 90°C rated building wire for 150W
max 40°C ambient application - represents
more than 75% of all applications.
ɀ Type 4X, marine outdoor locations.
ɀ Factory sealed - no external seals required.
ɀ Quick connect - fixture threads onto the
mounting module for easy installation.
ɀ One size luminaire for all medium base
incandescent lamps through 300W.
ɀ One size luminaire for all mogul base
incandescent lamps through 500W.
ɀ Small compact size - ceiling mount is 133⁄4⍯
long.
ɀ Shock absorbing receptacle.
ɀ Easy to assemble & relamp.
ɀ Silicone gaskets seal out dirt and moisture.
ɀ Epoxy powder coat for corrosion resistance.
ɀ Same mounting modules as used with the
EVM & EVLP series.

Standard Materials:

ɀ Body, mounting modules and guard - copperfree
aluminum
ɀ Globe - heat & impact resistant glass
ɀ Gaskets - silicone
ɀ External hardware - stainless steel
ɀ Reflectors - Krydon® fiberglass-reinforced
polyester

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2L:711))

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1, Groups C,D
Cl. I, Zone 1 & 2, Group IIB
Cl. II, Groups E,F,G (Max 150W-Med. base)
Cl. III & Simultaneous Presence (Max 150W-Med. base)
Marine and Wet Locations ɀ Type 4X; IP66

2L

Standard Finishes:

EVI series incandescent luminaires are used:
ɀ for Type 4X, marine, wet location and hose
down environments.
ɀ where a consistent light level relatively
unaffected by extremes in ambient temperature
(-40°C to +65°C) is required.
ɀ in areas that require lamps to reach full
illumination immediately.
ɀ in areas that require lamps to be frequently
turned on and off.
ɀ indoor & outdoor in locations which are
hazardous due to the presence of flammable
vapors or gases, ignitible dusts or ignitible fibers
& flyings.
ɀ where a luminaire is required for tough
environmental conditions involving corrosives,
water, dust and extreme temperatures.
ɀ manufacturing plants, heavy industrial facilities,
industrial process facilities such as refineries,
chemical, petrochemical, pharmaceutical and
platforms.
ɀ for lighting of loading docks, tunnels,
stairways, storage closets & task lighting.

CH0 0 4 F - 5

COLOR: CMYK

ɀ Copper free aluminum - Corro-free TM epoxy
powder coat
ɀ Stainless steel - Natural
ɀ Krydon® Reflectors - High reflectance white

Electrical Ratings:
Sources/Wattages
ɀ Medium Base - Maximum 300W (PS25)
ɀ Mogul Base - Maximum 500W (PS40)
Voltages
ɀ Medium Base 120V (250V with suffix /250)
ɀ Mogul Base 277V
Hub Size
ɀ3⁄4⍯ or 1⍯ NPT pendant, ceiling, wall mount
ɀ3⁄4⍯ NPT bulkhead mount

Certifications and Compliances:
NEC & CEC:
ɀ Class I, Division 1, Groups C & D
ɀ Class I, Zone 1, Group IIB
ɀ Class II, Groups E, F & G
ɀ Marine Locations, Wet Locations, Enclosure
Type 4X, IP66
ɀ UL Listed
ɀ cUL Listed (Certified by UL to CSA Standards)
NEC:
ɀ Class III; Simultaneous Presence
UL Standards:
ɀ 844 Electric Fixture Hangers for Hazardous
Locations
ɀ 1598 Luminaires
ɀ 1598A Luminaires for Installation on Marine
Vessels
CSA Standards:
ɀ C22.2 No. 137

Options:
Description
ɀ 250V luminaire for
export applications
(medium base only)

Suffix to be
added to Cat. No.
/250

Accessories:

ɀ Reflectors - See Ordering by Components on
page 713.

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

711

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0712-7 Name: 2L-712

2L

100:
DATE: JAN 19 2006

Time: 5:45:50 PM Operator: RB

EVI Series Explosionproof
Incandescent Luminaires
Factory Sealed
100-500W Medium and Mogul Base

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1, Groups C,D
Cl. I, Zone 1 & 2, Group IIB
Cl. II, Groups E,F,G (Max 150W-Med. base)
Cl. III & Simultaneous Presence (Max 150W-Med. base)
Marine and Wet Locations ɀ Type 4X; IP66

Mounting
Style

Hub
Size

EVI301 SERIES
Medium Base with
EV505 Guard
(Max. 300W PS25)

Pendant Mount

3⁄4⍯
1⍯

EVIA2301
EVIA3301

EVIA2501
EVIA3501

Ceiling Mount

3⁄4⍯
1⍯

EVICX2301
EVICX3301

EVICX2501
EVICX3501

Wall Mount

3⁄4⍯
1⍯

EVIBX2301
EVIBX3301

EVIBX2501
EVIBX3501

Bulkhead Mount

3⁄4⍯
1⍯

EVIBH2301
—

—
—

Stanchion Mount

11⁄4⍯

EVIJ4301

EVIJ4501

EVI301

EVI501

Luminaire with
Guard Less
Mounting Module

EVI501 SERIES
Mogul Base with
EV503 Guard
(Max. 500W PS40)

Note:
Medium base luminaires (EVI301 Series) - For A19 lamps up to 100W, use Leviton socket extension catalog number 2005.
Mogul base luminaires (EVI501 Series) - For PS30 medium base lamps, use Cooper Wiring Devices socket adapter catalog
number 332.
 - Available with Lightning Service TM Delivery. See Section G for complete details.

712

STIBOINFO((CRH:66008com:2L:712))
CH0 0 4 F - 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0713-6 Name: 2L-713

100:
DATE: JAN 19 2006

Time: 5:45:52 PM Operator: RB

EVI Series Explosionproof
Incandescent Luminaires

COLOR: CMYK

TCP: 15001

Ordering By Components

Typedriver Name: TS name csm no.: 100

2L

Factory Sealed
100-500W Medium and Mogul Base
EVI Luminaires are available in components.
A complete luminaire consists of:
I.
Mounting Module
II.
EVI Luminaire Body and Globe Assembly
III.
Guard, Reflector

I. Mounting Module:
Type
Pendant

Conduit

Cat. No.
EVMP2
EVMP3
EV22
EV33
EV22 & EV87
EV33 & EV87
EVMJ4
EVIJ2

3⁄4⍯

1⍯
3⁄4⍯
1⍯
3⁄4⍯
1⍯
11⁄4⍯
3⁄4⍯

Ceiling and Wall Box
Wall Bracket Arm
Stanchion
Bulk Head

II. Luminaire Body and Globe Assembly with Guard
Type
Medium Base
Mogul Base

Cat. No.
EVI301
EVI501

III. Guards and Reflectors
Type
Guard - Fits EVI301 Series (medium base)
Guard - Fits EVI501 Series (mogul base)
Dome Reflector - Fits EVI301 Series (medium base)
Angle Reflector - Fits EVI301 Series (medium base)
Dome Reflector - Fits EVI501 Series (mogul base)
Angle Reflector - Fits EVI501 Series (mogul base)

Cat. No.
EV505
EV503
RD636
RA636
RD739
RA739

 - Available with Lightning Service TM Delivery. See Section G for complete details.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2L:713))
CH0 0 4 F - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

713

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0714-5 Name: 2L-714

2L

100:
DATE: JAN 19 2006

Time: 5:45:53 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Family Tree
Temperature Performance Data

EVI Series Explosionproof
Incandescent Luminaires
Factory Sealed
100-500W Medium and Mogul Base

Temperature Performance Data:
Type

Watts/Lamp

EV1301
Medium
Base

100W/A21 or A19*
150W/A21
200W/A23 or A25
300W/PS25

EV1501
Mogul
Base

200W/PS30*
300W/PS35
500W/PS40

Class I, Div 1
(Class I, Zone 1)
Ambient
40°C
55°C
65°C

Class II
Ambient
40°C

Simultaneous
Presence
Ambient
40°C

Supply Wire
Temp (°C)
Ambient
40°C
55°C
65°C

T4
T4
T3
T3

T3C
T3C
T2D
T2D

T3C
T3C
T2C
T2C

T3C
T3C
—
—

T3C
T3C
—
—

90°C
90°C
105°C
105°C

105°C
105°C
125°C
125°C

125°C
125°C
125°C
125°C

T4A
T4
T3A

T4
T3C
T3

T4
T3C
T3

T3A
—
—

T3A
—
—

90°C
90°C
105°C

90°C
90°C
125°C

105°C
105°C
125°C

* Note:
Medium base luminaires (EVI301 Series) - For A19 lamps up to 100W, use Leviton socket extension catalog number 2005.
Mogul base luminaires (EVI501 Series) - For PS30 medium base lamps, use Cooper Wiring Devices socket adapter catalog number 332.

 - Available with Lightning Service TM Delivery. See Section G for complete details.

714

STIBOINFO((CRH:66008com:2L:714))
CH0 0 4 F - 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0715-6 Name: 2L-715

100:
DATE: JAN 19 2006

Time: 5:45:54 PM Operator: JB

EVI Series Explosionproof
Incandescent Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Medium Base Dimensions and Weights

2L

Factory Sealed
100-500W Medium and Mogul Base
Medium Base EVI Luminaire Dimensions (Inches):

Medium Base Net Luminaire Weights (lbs.):
EVI301 with guard

11 lbs.

Add mounting modules:
Pendant
Ceiling
Wall
Bulkhead
Stanchion

1.0 lbs
2.0 lbs
4.5 lbs
2.2 lbs
2.5 lbs

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2L:715))
CH0 0 4 F - 5

CAN: 1-800-265-0502

Add for Reflectors
RD636 (Dome Reflector, Small)
RA636 (Angle Reflector, Small)
RD739 (Dome Reflector, Small)
RA739 (Angle Reflector, Small)

Copyright© 2006 Cooper Crouse-Hinds

1.5 lbs
1.0 lbs
2.0 lbs
1.4 lbs

715

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0716-5 Name: 2L-716

2L

100:
DATE: JAN 19 2006

Time: 5:45:56 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Mogul Base Dimensions and Weights

EVI Series Explosionproof
Incandescent Luminaires
Factory Sealed
100-500W Medium and Mogul Base

Medium Base EVI Luminaire Dimensions (Inches):

Mogul Base Net Luminaire Weights (lbs.):
EVI501 with guard

24 lbs.

Add mounting modules:
Pendant
Ceiling
Wall
Bulkhead
Stanchion

1.0 lbs
2.0 lbs
4.5 lbs
2.2 lbs
2.5 lbs

716

STIBOINFO((CRH:66008com:2L:716))
CH0 0 4 F - 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Add for Reflectors
RD636 (Dome Reflector, Small)
RA636 (Angle Reflector, Small)
RD739 (Dome Reflector, Small)
RA739 (Angle Reflector, Small)

Copyright© 2006 Cooper Crouse-Hinds

1.5 lbs
1.0 lbs
2.0 lbs
1.4 lbs

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0717-10 Name: 2L-717

100:
DATE: JAN 19 2006

Time: 5:45:57 PM Operator: JB

COLOR: CMYK

TCP: 15001

Photometric Data

EVI Series Explosionproof
Incandescent Luminaires

Typedriver Name: TS name csm no.: 100

2L

Factory Sealed
100-500W Medium and Mogul Base
Medium Base
Luminaire with Globe and Guard
EVICX2301 Lamp: 300W/PS25 Incandescent

Medium Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVICX2300 Lamp: 300W/PS25 Incandescent

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2L:717))
CH0 0 4 F - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

717

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0718-9 Name: 2L-718

2L

100:
DATE: JAN 19 2006

Time: 5:45:58 PM Operator: JB

EVI Series Explosionproof
Incandescent Luminaires

COLOR: CMYK

TCP: 15001

Photometric Data

Factory Sealed
100-500W Medium and Mogul Base
Medium Base
Luminaire with Globe and 30° Angle Reflector (Less Guard)
EVICX2300 Lamp: 300W/PS25 Incandescent

Mogul Base
Luminaire with Globe and Guard
EVIA2501 Lamp: 500W/PS40 Incandescent

718

STIBOINFO((CRH:66008com:2L:718))
CH0 0 4 F - 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0719-9 Name: 2L-719

100:
DATE: JAN 19 2006

Time: 5:46:00 PM Operator: JB

COLOR: CMYK

TCP: 15001

Photometric Data

EVI Series Explosionproof
Incandescent Luminaires

Typedriver Name: TS name csm no.: 100

2L

Factory Sealed
100-500W Medium and Mogul Base
Mogul Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVIA2500 Lamp: 500W/PS40 Incandescent

Mogul Base
Luminaire with Globe and Angle Reflector (Less Guard)
EVIA2500 Lamp: 500W/PS40 Incandescent

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2L:719))
CH0 0 4 F - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

719

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0720-3 Name: 2L-720

2L

100:
DATE: JAN 19 2006

Time: 5:46:01 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 and 2, Groups A,B,C,D – Pendant Mount
Cl. I, Div. 1 and 2, Groups B,C,D – Ceiling and Bracket Mount
Wet Locations
NEMA 3,3R

EV Incandescent
Luminaires
Factory Sealed

Application:
EV292 Series luminaires are used:
ɀ to provide incandescent lighting in
locations made hazardous due to the
presence of hydrogen, gases or vapors of an
equivalent hazard, such as manufactured
gas.
ɀ hydrogen areas of process industries,
missile bases where hydrogen fuel is used
and gas manufacturing plants.
ɀ in areas of lesser hazard than indicated
above.
ɀ EVA292 pendant mount luminaire is also
suitable for use in locations made hazardous
due to the presence of acetylene.

Features:
ɀ Flametight threaded joints – no external
seal needed
ɀ Easy to assemble and relamp
ɀ Shock absorbing receptacle
ɀ Gasket seals out dirt and liquids
ɀ Positive locking of globe holder
ɀ Heat and impact resistant globe
ɀ Inner reflector eliminates upward spill light
ɀ Lightweight
ɀ Corrosion Resistant
ɀ Dome and 30° angle reflectors available

Pendant style
with RD725 dome reflector
Max.
Lamp
Style
Size
Pendant

Standard Materials:

Ceiling

ɀ Globes – heat and impact resistant glass
ɀ Luminaire and bracket arm – copper-free
aluminum
ɀ Reflectors – Krydon® fiberglass-reinforced
polyester
ɀ Back box – Feraloy® iron alloy

Bracket

Standard Finishes:

300 watt,
PS-30
(medium base)
300 watt,
PS-30
(medium base)
300 watt,
PS-30
(medium base)

Pendant style
with RA725 30° angle reflector
Without
Hub
Reflector
Size
Cat. #
3⁄4
EVA292
With
Guard

Pendant style
without reflector
Dome
30° Angle
Reflector
Reflector
Cat. #
Cat. #
RD725
RA725

With
Guard

3⁄4

EVCX292

RD725

With
Guard

3⁄4

EVBX292

Not Applicable

Dimensions
EVA

ɀ Aluminum – epoxy powder coat
ɀ Krydon – high reflectance white
ɀ Feraloy – electrogalvanized and aluminum
acrylic paint

EVBX

EVCX

Size Ranges:
ɀ 3⁄4⍯ conduit hub

Capacity Ranges:
ɀ 300 watt, PS-30 medium base lamps

Certifications and
Compliances:
ɀ NEC/CEC: Class I, Divisions 1 and 2,
Groups A,B,C,D – pendant
mount
Class I, Divisions 1 and 2,
Groups B,C,D – ceiling and
bracket mount
ɀ UL Standard: 844
ɀ CSA Standard: C22.2 No. 137

a
b
c

EVA
87⁄8
163⁄8
147⁄8

EVBX
87⁄8
181⁄8
165⁄8

EVCX
87⁄8
143⁄8
127⁄8

Reflector Diameter
Type
Dome
16⍯
30° Angle 16⍯

Temperature Performance
Data:
Class I Ambient Supply
Style
UL
Temp.°C Wire °C
Pendant
T3A
25/40
150°C
Ceiling
T3A
25/40
150°C
Bracket
T3A
25/40
150°C
NOTE: Photometric curves and data are the same as shown for EV Groups C, D series.

720

STIBOINFO((CRH:66008com:2L:720))
CH0 0 2 L - 9

RA725

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

EVCX

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0721-2 Name: 3L-721

100:
DATE: JAN 19 2006

Time: 5:46:02 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

High Intensity Discharge
(H.I.D.) Lighting
Hazardous and Non-Hazardous

3L

Description

Page No.

Application/Selection

722, 723

Champ® Series - Integrally Ballasted Luminaires
Accessories
Ballast Data (USA)
Ballast Data (Canada)

775, 776
677-682
677-682

DMV Series 50 – 250W H.I.D.

743
744-749
750, 751
752, 753

Catalog Listings
Dimensions, Weights, Temperature Data
Photometric Data

LMV Series 35 – 150W H.I.D
Catalog Listings
Dimensions, Weights, Temperature Data
Photometric Data

VMV Series 50 – 175W H.I.D
Catalog Listings
Dimensions, Weights, Temperature Data
Photometric Data

VMV High Wattage Series 200 – 400W H.I.D.
Catalog Listings
Dimensions, Weights, Temperature Data
Photometric Data

N2MV Non-Metallic H.I.D.
Catalog Listings
Dimensions, Weight, Temperature Data
Photometric Data

V2PC Photocell

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:721))
CH0 0 0 0 9 F

CAN: 1-800-265-0502

735
736-739
740, 741
742
724
725-731
731, 732
733, 734
754
755-760
761, 762
763, 764
765
766-770
771, 772
773, 774
777, 778

Copyright© 2006 Cooper Crouse-Hinds

721

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0722-1 Name: 3L-722

3L

DATE: JAN 19 2006

Time: 5:46:03 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

H.I.D. (High Intensity Discharge)
Luminaires
Enclosed & Gasketed
Application and Selection

Application:
Luminaires included in this section are
enclosed and gasketed, designed for use
with H.I.D. lamps as follows:
ɀ in locations where protection is required
from wet, dirty and corrosive atmospheres
ɀ where long life lamps provide desirable
maintenance cost savings and return on
investment through use of fewer luminaires,
circuits and ancillary apparatus.
ɀ where relamping and maintenance
difficulties require long life lamps.

Considerations for
Selection:
Environmental:
ɀ What are the hazardous areas
classifications (NEC/CEC) of the locations in
which the luminaires will be installed?
ɀ Must luminaires be suitable for use in
marine, hosedown, corrosive applications?
Lighting levels required:
ɀ What wattage luminaire(s) will provide the
desired light level? (See Lighting Selector
Guide, Section L to determine number and
location of luminaires required)

Product Selection:
Quick Selector Chart (See specific sections for lamp type and wattage suitability)
- Series -

- Watts

Hazardous Area & Other

HPS, MH &
MV Lamps

Enviromental Suitabilities
NEC, CEC, IEC

- Ballast Voltages -

Standard Voltage Ballasts
(60 Hz)
VMV Champ

50, 70, 100, 150, 175
Mogul Base

NEC & CEC
Cl. I, Div. 2 Groups A, B, C, D
Cl. II, Groups E, F, G
Class III
Simultaneous Presence

VMV High Wattage
Champ

200, 250, 400
Mogul Base

LMV Champ
Low Profile

35, 50, 70, 100, 150
Medium Base

Restricted Breathing (Suffix - S826)
CL. I Div. 2 & Zone 2 AEx nR, Ex nR IIC

NEC (UL)
Multi-tap: 120, 208, 240 & 277 Volt 60 Hz.
Dual-tap: 120 & 277 Volt 60 Hz (50W HPS)
120 Volt 60 Hz
480 Volt 60 Hz
CEC/CSA (cUL)
Tri-tap: 120, 277 & 347 Volt 60 Hz
Dual-tap: 120 & 277 Volt 60 Hz (50W HPS)
120 Volt 60 Hz

Marine Outdoor & Wet Locations

DMV Champ
Expanded
Class II Suitability

N2MV Champ
Non Metallic

722

STIBOINFO((CRH:66008com:3L:722))
CH0 0 3 L - 0

50, 70, 100, 150, 175, 250
Mogul Base

50, 70, 100, 150, 175
Mogul Base

US: 1-866-764-5454

Type 3, 3R, 4, 4X
IP56 to 1P66

IEC
Certified for IEC Zone 2
(Suffix - S826TB)
Ex nR IIC

Optional Voltage Ballasts
(50 or 60 Hz)

CEC/CSA (cUL)
208 Volt 60 Hz CWI - Isolated
240 Volt 60 Hz CWI - Isolated
480 Volt 60 Hz CWI - Isolated
600 Volt 60 Hz CWI - Isolated

IP 56 to IP 66

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

EXPORT
220 Volt 50 Hz
230 Volt 50 Hz
240 Volt 50 Hz

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0723-1 Name: 3L-723

100:
DATE: JAN 19 2006

Champ® H.I.D. Luminaires
VMV, LMV, DMV, VMV
High Wattage & N2MV Series

Time: 5:46:04 PM Operator: JB

COLOR: CMYK

ɀ

ɀ

ɀ

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2 (Suffix
S826TB)

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. II, Groups E, F, G, Cl. III
Simultaneous Presence
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP56 to IP66

3L

The Champ family is an extremely versatile
industrial lighting system. Five different series
of Champ Luminaires embrace a broad range
of wattages, lamp sources, compliances,
optics, and accessories. Each series is
covered in detail on the following pages.
General information to help in the proper
selection of series and luminaires is shown
below.

Application:
Heavy duty Champ lighting luminaires are
used:
ɀ in manufacturing plants, refineries,
chemical, petrochemical, and other industrial
process facilities, waste or sewage treatment
facilities, offshore, dockside, and harbor
installations, and other heavy industrial
applications
ɀ in areas where ignitible concentrations of
flammable gases or vapors will be present
only due to abnormal, unusual, or accidental
conditions
ɀ where combustible dusts are present
ɀ in marine applications where water spray
and corrosive atmospheres are
considerations
ɀ in elevated ambient temperatures often
found in industrial applications
ɀ in installations where moisture, dirt, dust,
vibration, corrosion, and rough usage are
problems
ɀ wherever the damaging effects of water,
wind, snow, sleet, hot sun, or any
combination of these elements are found.

Features:
ɀ Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent resistance to
corrosion.
ɀ Seven mounting arrangements in each
series, to suit any lighting layout – pendant,
flexible pendant, ceiling, wall bracket, angle
stanchion, straight stanchion, and quadmount.
ɀ Wide range of light sources and wattages
to meet specifiers’ needs: 35, 50, 70, 100,
150, 200, 250 and 400 watt high pressure
sodium (HPS); 100, 175, 250, and 400 watt
mercury vapor (MV); 70, 100 175, 250, and
400 watt metal halide (MH).
ɀ Hinged ballast housings for ease of
installation and maintenance; all mounting
modules fit all ballast housings.
ɀ Wide choice of photometric distributions.
Globes available for lamps up through 400
watt HPS, and 250 watt MV and MH. Glass
refractors available for all VMV and DMV
units; reflector/lens for 200-400 watt VMV
units
ɀ All luminaires are designed to perform in a
40°C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65°C.
ɀ Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in wet
and corrosive environments.

ɀ Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation
ɀ Low ambient capability to –40°C
ɀ Dome and 30° angle reflectors made of
bright white Krydon® fiberglass-reinforced
polyester material provide superior
reflectivity, with twist-on feature

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:723))
CH0 0 3 L - 1

CAN: 1-800-265-0502

requiring no tools or additional hardware. Will
not chip, peel, dent, rust, or corrode
ɀ Grounding wire for safety
ɀ Ballasts are high power factor (min P.F.
90%) and available in a variety of voltages to
meet local area requirements.

Copyright© 2006 Cooper Crouse-Hinds

723

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0724-9 Name: 3L-724

3L

100:
DATE: JAN 19 2006

Time: 5:46:05 PM Operator: RB

50-175W VMV Series
Champ® H.I.D. Luminaires

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III &
Simultaneous Presence
(HPS 50W, 70W)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66

Application:

Options:

VMV series Champ luminaires are used:
ɀ in manufacturing plants, refineries,
chemical, petrochemical, and other industrial
process facilities, waste or sewage treatment
facilities, offshore, dockside, and harbor
installations, and other heavy industrial
applications
ɀ in areas in which ignitible concentrations of
flammable gases or vapors will be present
only due to abnormal, unusual, or accidental
conditions
ɀ where combustible dusts are present
ɀ in marine applications where water spray
and corrosive atmospheres are
considerations
ɀ in elevated ambient temperatures often
found in industrial applications
ɀ in installations where moisture, dirt, dust,
vibration, corrosion, and rough usage are
problems
ɀ wherever the damaging effects of water,
wind, snow, sleet, hot sun, or any
combination of these elements are found

The following special options are available
from the factory by adding suffix to luminaire
Cat. No.:
Suffix to be
Description
added to Cat. No.

Features:
ɀ Compact, lightweight design is ideal for
medium and low mounting heights
ɀ Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent resistance to
corrosion
ɀ Seven mounting arrangements to suit any
lighting layout – pendant, flexible pendant,
ceiling, wall bracket, angle stanchion, straight
stanchion, and quad-mount
ɀ Wide range of light sources and wattages
to meet specifiers’ needs: 50, 70, 100, and
150 watt high pressure sodium (HPS); 100,
and 175 watt mercury vapor (MV); 70, 100,
175 watt metal halide (MH)
ɀ Hinged ballast housing for ease of
installation and maintenance
ɀ Wide choice of photometric distributions.
Glass globes, refractors and compact
refractors available for all wattage luminaires;
plastic refractors (for non-hazardous
applications only) for 50-100 watt luminaires
ɀ All luminaires are designed to perform in a
40° C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65°C.
ɀ Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in wet
and corrosive environments
ɀ Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation
ɀ Low ambient capability to (–40°C)
ɀ Dome and 30° angle reflectors made of
bright white Krydon® material provide
superior reflectivity, with twist-on feature
requiring no tools or additional hardware. Will
not chip, peel, dent, rust, or corrode
ɀ Grounding wire for safety
ɀ High power factor ballasts (Min P.F. 90%)
and available in a variety of voltages to meet
local area requirements.
ɀ Mogul base porcelain lamp socket

724

STIBOINFO((CRH:66008com:3L:724))
CH0 0 3 L - 2

COLOR: CMYK

ɀ Factory Sealed Champs . . . . . . . . . . S865†
- Class I Division 2 & Zone 2
- Provides T3 code without conduit or
cable seals
Restricted breathing/Non-sparking
ɀ Restricted Breathing Construction. . . S826†
- Class I Division 2 & Zone 2 Suitabilty
- Cooler Operating Temperatures (TNumbers)
ɀ Certified for IEC Zone 2 . . . . . . . . . . S826TB
- Furnished with terminal block, crimp
terminals and dedicated voltage ballasts
(no MT, DT or TT)

Standard Materials:
ɀ Ballast housings and mountings – copper
free aluminum (less than 0.4 of 1%)
ɀ Exterior hardware – stainless steel
ɀ Reflectors (dome and angle) – Krydon
fiberglass-reinforced polyester material
ɀ Globes – heat and impact resistant
internally fluted glass
ɀ Refractors – glass (50-175 watts); plastic
(50-100 watts), for non-hazardous applications.
ɀ Guards: globe – copper-free aluminum
refractor – stainless steel

Standard Finishes:
ɀ Copper-free aluminum – epoxy powder
coat
ɀ Krydon material – high reflectance white
ɀ Stainless steel – natural

Electrical Ratings:
ɀ 120, 208, 240, 277, 347, 480, 600, Multitap刁 (120, 208, 240 and 277)
ɀ 50 to 150W HPS; 100 to 175W MV; 70 to
175W MH

Certifications and
Compliances:
ɀ NEC & CEC:
- Class I, Division 2, Groups A,B,C,D
- HPS 50W, 70W - Class II, Class III &
Simultaneous Presence (Class I,
Division 2 and Class II)
- Class I Zone 2
ɀ IEC:
- Zone 2 Ex nR IIC
ɀ UL Standards:
- 844, 2279 Hazardous (Classified)
Locations
- 1598 Luminaires
- 1598A Marine Locations
ɀ CSA Standards
- C22.2 No. 137
ɀ IEC Standards
- 60079-15
ɍ VMV Series now available with Champ Induction
Lighting System. See Section 5L.

US: 1-866-764-5454

CAN: 1-800-265-0502

ɀ Fused – to protect ballast and capacitors
against abnormal line conditions . . . . . S658*
(Not for use in Canada)
ɀ Ballast-Gard TM starter cut-out switch –
prevents starter pulsing when lamp is cycling
or inoperative; prolongs ballast and ignitor
life. Available for use with 50-150W LX HPS
only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG
ɀ Instant restrike – enables a hot HPS lamp to
immediately restrike after a momentary loss
of arc due to voltage fluctuation or power
outage. It has no effect on the warm-up
period of cold lamps. Available for use with
50-150W LX HPS
only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IR
ɀ Quartz auxiliary lighting for use with R2 &
R5 large glass refractors only! – comes to full
brightness immediately and remains lit until
the HID lamp attains 60-70% of full
illumination. For non-hazardous locations
only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QTZ
ɀ Stainless steel insert - top hat with stainless
steel threaded insert to attach ballast housing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S806
ɀ TEFLON coating on globe for increased
shatter protection. . . . . . . . . . . . . . . . . . . . S808
T-Numbers not affected
ɀ Factory assembled with H.I.D. lamps
installed for additional labor savings. . . . . . FA
(Note: BG and IR options cannot be used
together. IR and QTZ options cannot be used
together.)

Accessories:
ɀ See pages 775 and 776 for complete
listing.
TEFLON is a registered trademark of E.I. duPont Co.
* When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.
† For detailed information on Restricted Breathing and
Non-Sparking, see page 32 of the Cooper Crouse-Hinds
2005 Code Digest.

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0725-5 Name: 3L-725

DATE: JAN 19 2006

Time: 5:46:06 PM Operator: JB

ɀ

50-150W High
Pressure Sodium
VMV Series

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing CL. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

Champ® H.I.D. Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

CL. II Groups E, F, G, CL. III &
Simultaneous Presence (50W,
70W)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66

3L

See Notes 1 (to specify voltage), 2 and 3. For guards and other optics see VMV Luminaires – Ordering by Components section.
BASIC CATALOG NUMBER
Mounting
Style

Hub
Size

Lamp With G24 Globe
Watts and P21 Guard

With G241 Type I
Compact Refractor

With G245 Type V
Compact Refractor

With R5 Glass
Refractor

VMVS2A050GP
VMVS3A050GP
VMVS2A070GP
VMVS3A070GP
VMVS2A100GP
VMVS3A100GP
VMVS2A150GP
VMVS3A150GP

VMVS2A050G241
VMVS3A050G241
VMVS2A070G241
VMVS3A070G241
VMVS2A100G241
VMVS3A100G241
VMVS2A150G241
VMVS3A150G241

VMVS2A050G245
VMVS3A050G245
VMVS2A070G245
VMVS3A070G245
VMVS2A100G245
VMVS3A100G245
VMVS2A150G245
VMVS3A150G245

VMVS2A050R5
VMVS3A050R5
VMVS2A070R5 
VMVS3A070R5 
VMVS2A100R5 
VMVS3A100R5 
VMVS2A150R5 
VMVS3A150R5 

3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1

50

3⁄4

50
70
100
150

VMVS2HA050GP
VMVS2HA070GP
VMVS2HA100GP
VMVS2HA150GP

VMVS2HA050G241
VMVS2HA070G241
VMVS2HA100G241
VMVS2HA150G241

VMVS2HA050G245
VMVS2HA070G245
VMVS2HA100G245
VMVS2HA150G245

VMVS2HA050R5
VMVS2HA070R5
VMVS2HA100R5
VMVS2HA150R5

3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1

50

VMVS2C050GP
VMVS3C050GP
VMVS2C070GP
VMVS3C070GP
VMVS2C100GP
VMVS3C100GP
VMVS2C150GP
VMVS3C150GP

VMVS2C050G241
VMVS3C050G241
VMVS2C070G241
VMVS3C070G241
VMVS2C100G241
VMVS3C100G241
VMVS2C150G241
VMVS3C150G241

VMVS2C050G245
VMVS3C050G245
VMVS2C070G245
VMVS3C070G245
VMVS2C100G245
VMVS3C100G245
VMVS2C150G245
VMVS3C150G245

VMVS2C050R5
VMVS3C050R5
VMVS2C070R5 
VMVS3C070R5 
VMVS2C100R5 
VMVS3C100R5 
VMVS2C150R5 
VMVS3C150R5 

3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1

50

VMVS2TW050GP
VMVS3TW050GP
VMVS2TW070GP
VMVS3TW070GP
VMVS2TW100GP
VMVS3TW100GP
VMVS2TW150GP
VMVS3TW150GP

VMVS2TW050G241 VMVS2TW050G245 VMVS2TW050R5
VMVS3TW050G241 VMVS3TW050G245 VMVS3TW050R5
VMVS2TW070G241 VMVS2TW070G245 VMVS2TW070R5 
VMVS3TW070G241 VMVS3TW070G245 VMVS3TW070R5 
VMVS2TW100G241 VMVS2TW100G245 VMVS2TW100R5 
VMVS3TW100G241 VMVS3TW100G245 VMVS3TW100R5 
VMVS2TW150G241 VMVS2TW150G245 VMVS2TW150R5 
VMVS3TW150G241 VMVS3TW150G245 VMVS3TW150R5 

Quad-Mount
Pendant,
Adjustable
Thru-Feed,
25° Angle,
121⁄2 ° Angle

3⁄4

3⁄4

50
70
100
150

VMVS25Q050GP
VMVS25Q070GP
VMVS25Q100GP
VMVS25Q150GP

VMVS25Q050G241
VMVS25Q070G241
VMVS25Q100G241
VMVS25Q150G241

VMVS25Q050G245
VMVS25Q070G245
VMVS25Q100G245
VMVS25Q150G245

VMVS25Q050R5
VMVS25Q070R5
VMVS25Q100R5
VMVS25Q150R5

Stanchion
Mount
25° Angle

11⁄2
11⁄2
11⁄2
11⁄2

50
70
100
150

VMVSJ050GP
VMVSJ070GP
VMVSJ100GP
VMVSJ150GP

VMVSJ050G241
VMVSJ070G241
VMVSJ100G241
VMVSJ150G241

VMVSJ050G245
VMVSJ070G245
VMVSJ100G245
VMVSJ150G245

VMVSJ050R5
VMVSJ070R5 
VMVSJ100R5 
VMVSJ150R5 

Stanchion
Mount
Straight

11⁄2
11⁄2
11⁄2
11⁄2

50
70
100
150

VMVSP050GP
VMVSP070GP
VMVSP100GP
VMVSP150GP

VMVSP050G241
VMVSP070G241
VMVSP100G241
VMVSP150G241

VMVSP050G245
VMVSP070G245
VMVSP100G245
VMVSP150G245

VMVSP050R5
VMVSP070R5 
VMVSP100R5 
VMVSP150R5 

Pendant Mount

Flexible
Pendant Mount

3⁄4
3⁄4
3⁄4

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

3⁄4
3⁄4

70
100
150

70
100
150

70
100
150

Standard Voltage Ballasts - 60Hz
NEC/UL
1.

Voltage
Multi Tap
Dual Tap
Suffix
/MT
/DT
(Multi Tap and Dual Tap ballasts are prewired for 277V)

120V
/120

480V
/480

CEC/CSA (cUL)
Tri Tap
/TT

Dual Tap
/DT

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts

EXPORT

Voltage
208V CWI
240V CWI
480V CWI
600V CWI
220V 60Hz
220V 50Hz
Suffix
/208CWI
/240CWI
/480CWI
/600CWI
/220
/220 50
2. 150W HPS Luminaires, 55V Lamps is standard; for 100V lamps - Add suffix ‘‘CE’’. 50W HPS Luminaire is dual tap only.
3. Options - Add the required options suffixes from page 724, In Alpha-numeric order.
 – available with Lightning Service TM delivery. See Section G for complete details.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:725))
CH0 0 3 L - 3

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

120V
/120

230V 50Hz
/230 50

240V 50Hz
/240 50

725

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0726-2 Name: 3L-726

3L

DATE: JAN 19 2006

Time: 5:46:08 PM Operator: RB

150-175W Pulse Start
Metal Halide VMV
Series
Champ® H.I.D. Luminaires

COLOR: CMYK

TCP: 15001

ɀ

ɀ

ɀ

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div 2 & Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2 (Suffix
S826TB)

Typedriver Name: TS name csm no.: 100

Marine & Wet Locations
3, 3R, 4, 4X; IP66

See Note 1 (to specify voltage). For guards and other optics see VMV Luminaires – Ordering by Components section.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Hub
Size
3⁄4
1
3⁄4
1

Lamp With G24 Globe
Watts and P21 Guard
150
VMVM2A150GP-S828
VMVM3A150GP-S828
175
VMVM2A175GP-S828
VMVM3A175GP-S828

With G245 Type V
Compact Refractor
VMVM2A150G245-S828
VMVM3A150G245-S828
VMVM2A175G245-S828
VMVM3A175G245-S828

With R5 Glass
Refractor
VMVM2A150R5-S828
VMVM3A150R5-S828
VMVM2A175R5-S828
VMVM3A175R5-S828

150
175

VMVM2HA150GP-S828
VMVM2HA175GP-S828

VMVM2HA150G245-S828
VMVM2HA175G245-S828

VMVM2HA150R5-S828
VMVM2HA175R5-S828

VMVM2C150GP-S828
VMVM3C150GP-S828
VMVM2C175GP-S828
VMVM3C175GP-S828

VMVM2C150G245-S828
VMVM3C150G245-S828
VMVM2C175G245-S828
VMVM3C175G245-S828

VMVM2C150R5-S828
VMVM3C150R5-S828
VMVM2C175R5-S828
VMVM3C175R5-S828

VMVM2TW150GP-S828
VMVM3TW150GP-S828
VMVM2TW175GP-S828
VMVM3TW175GP-S828

VMVM2TW150G245-S828
VMVM3TW150G245-S828
VMVM2TW175G245-S828
VMVM3TW175G245-S828

VMVM2TW150R5-S828
VMVM3TW150R5-S828
VMVM2TW175R5-S828
VMVM3TW175R5-S828

Flexible Pendant
Mount

3⁄4

Ceiling Mount
Thru-Feed

3⁄4
1
3⁄4
1

150

3⁄4
1
3⁄4
1

150

Quad-Mount
Pendant,
Adjustable ThruFeed, 25° Angle,
121⁄2° Angle

3⁄4
3⁄4

150
175

VMVM25Q150GP-S828
VMVM25Q175GP-S828

VMVM25Q150G245-S828
VMVM25Q175G245-S828

VMVM25Q150R5-S828
VMVM25Q175R5-S828

Stanchion
Mount 25° Angle

11⁄2
11⁄2

150
175

VMVMJ150GP-S828
VMVMJ175GP-S828

VMVMJ150G245-S828
VMVMJ175G245-S828

VMVMJ150R5-S828
VMVMJ175R5-S828

Stanchion
Mount Straight

11⁄2
11⁄2

150
175

VMVMP150GP-S828
VMVMP175GP-S828

VMVMP150G245-S828
VMVMP175G245-S828

VMVMP150R5-S828
VMVMP175R5-S828

Wall Mount
Thru-Feed

3⁄4

175

175

1.
Voltage
Suffix

Multi Tap
/MT

Standard Voltage Ballasts - 60Hz
NEC/UL
120V
480V
/120
/480

CEC/CSA (cUL)
Tri Tap
/TT

Optional Voltage Ballasts - 50 or 60Hz
EXPORT
Voltage
Suffix

726

STIBOINFO((CRH:66008com:3L:726))
CH0 0 3 L - 5

220V 60Hz
/220

US: 1-866-764-5454

220V 50Hz
/220 50

CAN: 1-800-265-0502

230V 50Hz
/230 50

240V 50Hz
/240 50

Copyright© 2006 Cooper Crouse-Hinds

120V
/120

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0727-3 Name: 3L-727

DATE: JAN 19 2006

100-175W Metal
Halide VMV Series
Champ® H.I.D. Luminaires

Time: 5:46:09 PM Operator: JB

COLOR: CMYK

ɀ

ɀ

ɀ

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div 2 & Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2 (Suffix
S826TB)

TCP: 15001

Typedriver Name: TS name csm no.: 100

Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

See Note 1 (to specify voltage), 2 and 3. For guards and other optics see VMV Luminaires – Ordering by Components section.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Hub
Size
3⁄4
1
1
3⁄4
1

Flexible
Pendant Mount

3⁄4

Lamp With G24 Globe
Watts and P21 Guard
70
VMVM2A070GP
VMVM3A070GP
100
VMVM2A100GP
VMVM3A100GP
175
VMVM2A175GP
VMVM3A175GP

With G241 Type I
Compact Refractor
VMVM2A070G241
VMVM3A070G241
VMVM2A100G241
VMVM3A100G241
VMVM2A175G241
VMVM3A175G241

With G245 Type V
Compact Refractor
VMVM2A070G245
VMVM3A070G245
VMVM2A100G245
VMVM3A100G245
VMVM2A175G245
VMVM3A175G245

70
100
175

VMVM2HA070GP
VMVM2HA070G241 VMVM2HA070G245 VMVM2HA070R5
VMVM2HA100GP VMVM2HA100G241 VMVM2HA100G245 VMVM2HA100R5
VMVM2HA175GP VMVM2HA175G241 VMVM2HA175G245 VMVM2HA175R5

3⁄4
1
3⁄4
1
3⁄4
1

70

VMVM2C070GP
VMVM3C070GP
VMVM2C100GP
VMVM3C100GP
VMVM2C175GP
VMVM3C175GP

VMVM2C070G241
VMVM3C070G241
VMVM2C100G241
VMVM3C100G241
VMVM2C175G241
VMVM3C175G241

3⁄4
1
3⁄4
1
3⁄4
1

70

VMVM2TW070GP
VMVM3TW070GP
VMVM2TW100GP
VMVM3TW100GP
VMVM2TW175GP
VMVM3TW175GP

VMVM2TW070G241 VMVM2TW070G245 VMVM2TW070R5
VMVM3TW070G241 VMVM3TW070G245 VMVM3TW070R5
VMVM2TW100G241 VMVM2TW100G245 VMVM2TW100R5
VMVM3TW100G241 VMVM3TW100G245 VMVM3TW100R5
VMVM2TW175G241 VMVM2TW175G245 VMVM2TW175R5
VMVM3TW175G241 VMVM3TW175G245 VMVM3TW175R5

Quad-Mount
Pendant,
Adjustable
Thru-Feed,
25° Angle,
121⁄2° Angle

3⁄4
3⁄4

70
100
175

VMVM25Q070GP
VMVM25Q100GP
VMVM25Q175GP

VMVM25Q070G241
VMVM25Q100G241
VMVM25Q175G241

VMVM25Q070G245
VMVM25Q100G245
VMVM25Q175G245

VMVM25Q070R5
VMVM25Q100R5
VMVM25Q175R5

Stanchion
Mount 25° Angle

11⁄2
11⁄2
11⁄2

70
100
175

VMVMJ070GP
VMVMJ100GP
VMVMJ175GP

VMVMJ070G241
VMVMJ100G241
VMVMJ175G241

VMVMJ070G245
VMVMJ100G245
VMVMJ175G245

VMVMJ070R5
VMVMJ100R5 
VMVMJ175R5 

Stanchion
Mount Straight

11⁄2
11⁄2
11⁄2

70
100
175

VMVMP070GP
VMVMP100GP
VMVMP175GP

VMVMP070G241
VMVMP100G241
VMVMP175G241

VMVMP070G245
VMVMP100G245
VMVMP175G245

VMVMP070R5
VMVMP100R5 
VMVMP175R5 

3⁄4
3⁄4

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

3⁄4

100
175

100
175

1.
Voltage
Suffix

Multi Tap
/MT

Standard Voltage Ballasts - 60Hz
NEC/UL
120V
480V
/120
/480

VMVM2C070G245
VMVM3C070G245
VMVM2C100G245
VMVM3C100G245
VMVM2C175G245
VMVM3C175G245

CEC/CSA (cUL)
Tri Tap
/TT

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
208V CWI
480V CWI
600V CWI
Suffix
/208CWI
/240CWI
/600CWI
2. Options - Add the required options suffixes from page 718, In Alpha-numeric order.
3. 70W Ballast not available in 480V.
 – available with Lightning Service TM delivery. See Section G for complete details.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:727))
CH0 0 3 L - 4

With R5 Glass
Refractor
VMVM2A070R5
VMVM3A070R5
VMVM2A100R5
VMVM3A100R5
VMVM2A175R5
VMVM3A175R5

CAN: 1-800-265-0502

VMVM2C070R5
VMVM3C070R5
VMVM2C100R5 
VMVM3C100R5 
VMVM2C175R5 
VMVM3C175R5 

120V
/120

EXPORT
220V 60Hz
/220

220V 50Hz
/220 50

Copyright© 2006 Cooper Crouse-Hinds

230V 50Hz
/230 50

240V 50Hz
/240 50

727

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0728-3 Name: 3L-728

3L

DATE: JAN 19 2006

Time: 5:46:10 PM Operator: JB

100-175W Mercury
Vapor VMV Series
Champ® H.I.D. Luminaires

COLOR: CMYK

TCP: 15001

ɀ

ɀ

ɀ

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div 2 & Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2 (Suffix
S826TB)

Typedriver Name: TS name csm no.: 100

Marine & Wet Locations
3, 3R, 4, 4X; IP66

See Notes 1 (to specify voltage) and 2. For guards and other optics see VMV Luminaires – Ordering by Components section.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Hub
Size
3⁄4
1
3⁄4
1

Lamp With G24 Globe
Watts and P21 Guard
100
VMVC2A100GP
VMVC3A100GP
175
VMVC2A175GP
VMVC3A175GP

With G241 Type I
Compact Refractor
VMVC2A100G241
VMVC3A100G241
VMVC2A175G241
VMVC3A175G241

Flexible
Pendant Mount

3⁄4
3⁄4

100
175

VMVC2HA100GP VMVC2HA100G241 VMVC2HA100G245 VMVC2HA100R5 
VMVC2HA175GP VMVC2HA175G241 VMVC2HA175G245 VMVC2HA175R5 

Ceiling Mount
Thru-Feed

3⁄4

100

1
3⁄4
1

175

VMVC2C100GP
VMVC3C100GP
VMVC2C175GP
VMVC3C175GP

VMVC2C100G241
VMVC3C100G241
VMVC2C175G241
VMVC3C175G241

VMVC2TW100GP
VMVC3TW100GP
VMVC2TW175GP
VMVC3TW175GP

VMVC2TW100G241 VMVC2TW100G245 VMVC2TW100R5
VMVC3TW100G241 VMVC3TW100G245 VMVC3TW100R5
VMVC2TW175G241 VMVC2TW175G245 VMVC2TW175R5
VMVC3TW175G241 VMVC3TW175G245 VMVC3TW175R5

Quad-Mount
Pendant,
Adjustable
Thru-Feed,
25° Angle,
121⁄2° Angle

3⁄4
3⁄4

100
175

VMVC25Q100GP
VMVC25Q175GP

VMVC25Q100G241
VMVC25Q175G241

VMVC25Q100G245
VMVC25Q175G245

VMVC25Q100R5
VMVC25Q175R5

Stanchion
Mount
25° Angle

11⁄2
11⁄2

100
175

VMVCJ100GP
VMVCJ175GP

VMVCJ100G241
VMVCJ175G241

VMVCJ100G245
VMVCJ175G245

VMVCJ100R5 
VMVCJ175R5 

Stanchion
Mount
Straight

11⁄2
11⁄2

100
175

VMVCP100GP
VMVCP175GP

VMVCP100G241
VMVCP175G241

VMVCP100G245
VMVCP175G245

VMVCP100R5 
VMVCP175R5 

Voltage
Suffix

175

Multi Tap
/MT

Standard Voltage Ballasts - 60Hz
NEC/UL
120V
480V
/120
/480

Optional Voltage Ballasts - 50 or 60Hz
EXPORT
Voltage
220V 60Hz
220V 50Hz
Suffix
/220
/220 50
2. Options - Add the required options suffixes from page 724, In Alpha-numeric order.
 – available with Lightning Service TM delivery. See Section G for complete details.

STIBOINFO((CRH:66008com:3L:728))

VMVC2C100R5 
VMVC3C100R5 
VMVC2C175R5 
VMVC3C175R5 

100

1.

CH0 0 3 L - 4

VMVC2C100G245
VMVC3C100G245
VMVC2C175G245
VMVC3C175G245

With R5 Glass
Refractor
VMVC2A100R5 
VMVC3A100R5 
VMVC2A175R5 
VMVC3A175R5 

3⁄4
1
3⁄4
1

Wall Mount
Thru-Feed

728

With G245 Type V
Compact Refractor
VMVC2A100G245
VMVC3A100G245
VMVC2A175G245
VMVC3A175G245

US: 1-866-764-5454

CAN: 1-800-265-0502

CEC/CSA (cUL)
Tri Tap
/TT

230V 50Hz
/230 50

Copyright© 2006 Cooper Crouse-Hinds

120V
/120

240V 50Hz
/240 50

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0729-1 Name: 3L-729

100:
DATE: JAN 19 2006

Time: 5:47:11 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

VMV Luminaires Ordering by Components

3L

VMV luminaires are available in components.
A complete luminaire consists of:
I.
Champ Cover (Mounting Module)
II.
VMV Ballast Housing - Include voltage and required option(s)
III.
Optical & Guard components - Globe, Reflector, Refractor, Guard

I. Champ Cover (Mounting Module)
Type
Pendant
Flexible Pendant
Ceiling
Wall
Stanchion - 25 Degree Angle
Stanchion - Straight
Quad-Mount

Conduit
3⁄4

1
3⁄4
3⁄4
1
3⁄4
1
11⁄2
11⁄2
3⁄4

Cat. No.
APM2
APM3
HPM2
CM2
CM3
TWM2
TWM3
JM5
PM5
QM25

II. Ballast Housings. Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Type

High Pressure Sodium

Metal Halide

Mercury Vapor

Lamp Watts

Cat No.
For Globe and
Compact Refractor
VMVS050/MT
VMVS070/MT
VMVS100/MT
VMVS150/MT LX
VMVM070/MT
VMVM100/MT
VMVM175/MT
VMVC100/MT
VMVC175/MT

50
70
100
150
70
100
175
100
175

For Large Refractor
VMVS050/MT-RM
VMVS070/MT-RM
VMVS100/MT-RM
VMVS150/MT LX-RM
VMVM070/MT-RM
VMVM100/MT-RM
VMVM175/MT-RM
VMVC100/MT-RM
VMVC175/MT-RM

III. Globe, Reflectors, Refractors, Guards
Type
Globe
Globe - Teflon Coated
Globe Guard
Reflector - Dome
Reflector - Angle

Cat. No.
G24
G24-S808
P21
RD70
RA70

Compact Refractor Type 1
Compact Refractor Type 5
Compact Refractor Guard

G241
G245
P241

Large Refractor Type 2
Large Refractor Type 5
Large Refractor Guard

R2
R5
P23

Large Plastic Refractor Type 2
Large Plastic Refractor Type 3
Large Plastic Refractor Type 5

PR2
PR3
PR5

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:729))
CH0 0 3 L - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

729

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0730-2 Name: 3L-730

3L

100:
DATE: JAN 19 2006

Time: 5:47:12 PM Operator: JB

50-175W VMV Series

COLOR: CMYK

TCP: 15001

Family Tree

Champ® H.I.D. Luminaires

 – available with Lightning Service TM delivery. See Section G for complete details.
* Plastic refractors are for non-hazardous areas only (50-100W Max.)

730

STIBOINFO((CRH:66008com:3L:730))
CH0 0 3 L - 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0731-36 Name: 3L-731

DATE: JAN 19 2006

Time: 5:47:13 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Temperature Performance Data

50-175W VMV Series

3L

®

Champ H.I.D Luminaires

LAMP

Cat. No.
VMVC100-S712
VMVC100
VMVC175
VMVM70
VMVM70
VMVM70
VMVM100
VMVM100-S849
VMVM100
VMVM150
VMVM175
VMVS50
VMVS50
VMVS50
VMVS70
VMVS70
VMVS100
VMVS100
VMVS150
VMVS150
VMVIG055
VMVIG055

Wattage

Type

100
100
175
70
70
70
100
100
100
150
175
50
50
50
70
70
100
100
150
150
55
55

MV
MV
MV
MH
MH
MH
MH
MH
MH
MH
MH
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
Induction
Induction

RATED
AMBIENT
°C

CLASS II,
DIVISION 1

CLASS I, DIVISION 2

Globe
Globe (G24)
(G24) w/
w/ or w/o
Reflector Refractor
Reflector
Globe (RA70 or (G241 or
(RA70 or
(G24)
RD70)
G245) Group
RD70)
40
40
40
40
55
65
40
40
55
40
40
40
55
65
40
55
40
55
40
55
40
55

T2B
—
T2
T3A
T3
T3
T2D
T2
T2D
T2A
T2A
T3A
T3A
T3
T3
T3
T2C
T2B
T2A
T2
T2C
T2C

T2B
—
T2
T3A
T3
T3
T2D
T2
T2D
T2A
T2A
T3A
T3A
T3
T3
T3
T2C
T2B
T2A
T2
T2C
T2C

—
—
T2B
T3A
T3
T3
T2D
T2
T2D
T2B
T2B
T3B
T3A
T3
T3B
T3
T2D
T2C
T2B
T2A
—
—

EFG
EFG
EFG
EFG
EFG
EFG
EFG

T4A
T4
T4
T3C
T3C
T3A

CLASS I, ZONE 2
Simultaneous
Presence
Class I, Div. 2
Class II, Div.2

T3A
T3
T2D
T2C
T2B
T2A

Restricted
Breathing
Suffix
Factory Sealed
S826 w/
Suffix S865
Globe (G24) AEx nA nR II
T4
T4
T3
T5
T4
T4
T4
T4
T4
T3
T3
T5
T5
T5
T4
T4
T4
T3
T3
T3
T6
T5

T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
—
—

SUPPLY WIRE
SUITABLE FOR °C

Globe
(G24)

Refractor
(G241 or
G245)

75
75
90
90
90
90
90
75
90
90
90
75
75
75
75
90
90
105
90
105
65
65

—
75
85
90
90
90
90
75
90
90
90
65
75
75
65
90
75
90
85
105
—
—

The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires are listed to UL 844. UL
844 specifies how the temperatures are measured.
The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring temperatures. Since NEC® 501.1
states that equipment “...for use in Class I, Zone 0, 1 or 2 locations shall be permitted in Class I, Division 2 locations...” then these luminaires are suitable for Class I,
Division 2 but with lower temperature ratings. They also have the advantage of meeting the more rigorous mechanical tests of UL 844.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:731))
CH0 0 3 L - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

731

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0732-1 Name: 3L-732

3L

DATE: JAN 19 2006

Time: 5:47:14 PM Operator: JB

50-175W VMV Series

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Dimensions and Weights

Champ® H.I.D. Luminaires

Pendant Mount

Ceiling Mount Top View

Net Luminaire Weights (lbs.):
Luminaire
Lamp Watts
Series 50
70
100
150
175
Luminaire with Globe, Guards (lbs):
141⁄2
141⁄2
141⁄2
VMVS
131⁄2
VMVC
131⁄4
151⁄2
VMVM
13
131⁄4
151⁄2
Luminaire with Glass Refractor (lbs):
223⁄4
223⁄4
223⁄4
VMVS
213⁄4
VMVC
211⁄2
233⁄4
VMVM
21
211⁄2
233⁄4
Add for mounting modules (lbs):
Quad-Mount
31⁄2
Pendant
11⁄4
Flexible Pendant 11⁄2
Angle Stanchion 31⁄2
Ceiling
23⁄4
Straight Stanchion 41⁄2
Wall
41⁄2
Add for reflectors (lbs):
30° Angle
11⁄2
Dome
11⁄2
1
Deduct: ⁄2 lb. for fixture without P21 Guard

Quad-Mount
Ceiling Mount

25° Angle
Stanchion Mount

Straight Stanchion Mount

Wall Mount

Luminairee With:
Refractors, Guard

Compact Refractor

Globe, Guard, Reflectors

732

STIBOINFO((CRH:66008com:3L:732))
CH0 0 3 L - 6

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0733-2 Name: 3L-733

DATE: JAN 19 2006

Time: 5:47:16 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

50-175W VMV Series

3L

®

Champ H.I.D. Luminaires

Lamp: 100W/E-231⁄2 high pressure sodium (HPS)
Total bare lamp lumens: 9500
To determine number and placement of luminaires see Lighting Selector Guide, pages 665 to 689.
NOTE: All data provided is for high pressure sodium luminaires with 100W/E-231⁄2 clear lamps. Use
conversion factors (multipliers) shown below for other clear lamp types and wattages. Consult Cooper
Crouse-Hinds for additional photometric data on any Champ Series luminaire.

Luminaire with Globe and Dome Reflector
Multipliers (for use with
candela curve only).
ConLuminaire Lamp version
Series
Watts Factor
VMVS
50
0.42
70
0.67
150
1.68

Isofootcandle Chart: Luminaire with Globe and Dome
Reflector

Luminaire spacing ratio: 1.85

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Cell
80

70

50

30

10
0
% Reflectance
Eff. Cell
80

70

50

30

10
0

Wall
50
30
10
50
30
10
50
30
10
50
30
10
50
30
10
0
Wall
50
30
10
50
30
10
50
30
10
50
30
10
50
30
10
0

Room Cavity Ratio
1
2
3
.823
.707
.610
.784
.646
.538
.749
.594
.482
.804
.690
.597
.767
.633
.530
.734
.587
.477
.765
.658
.571
.735
.611
.513
.709
.569
.466
.731
.629
.546
.708
.591
.497
.685
.555
.456
.701
.603
.524
.681
.569
.482
.662
.541
.446
.644
.521
.427
Room Cavity Ratio
6
7
8
.412
.366
.326
.334
.290
.253
.278
.239
.201
.403
.359
.320
.329
.285
.250
.274
.235
.200
.386
.344
.307
.320
.277
.244
.271
.231
.197
.371
.329
.296
.312
.272
.237
.267
.227
.195
.357
.319
.285
.304
.266
.232
.263
.224
.192
.245
.207
.176

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:733))
CH0 0 3 L - 7

4
.529
.451
.391
.517
.445
.388
.494
.431
.381
.473
.419
.375
.454
.406
.367
.348

5
.464
.384
.324
.452
.377
.321
.434
.368
.318
.416
.357
.312
.399
.348
.307
.288

9
.296
.224
.175
.291
.221
.174
.279
.216
.172
.269
.210
.170
.260
.206
.167
.152

10
.258
.187
.142
.252
.187
.142
.244
.182
.140
.235
.178
.137
.227
.173
.135
.120

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with Globe and 30°
Angle Reflector

Isofootcandle charts show illumination in footcandles on work plane 10
feet below light center. Multiply by factor shown to convert to other
mounting heights.
Height (Ft.)
Factor
Height (Ft.)
Factor
6
2.78
14
0.51
8
1.56
16
0.39
12
0.70

Copyright© 2006 Cooper Crouse-Hinds

733

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0734-2 Name: 3L-734

100:
DATE: JAN 19 2006

Time: 5:47:17 PM Operator: RB

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

50-175W VMV Series

3L

COLOR: CMYK

Champ® H.I.D. Luminaire

Lamp: 100W/E-231⁄2 high pressure sodium (HPS)
To determine number and placement of luminaires, see Lighting
Selector Guide, pages 665 to 689.

Lamp: 175W/E-28 mercury vapor (MV)
To determine number and placement of luminaires, see Lighting
Selector Guide, pages 665 to 689.

Luminaire with I.E.S. Type V Glass Refractor

Luminaire with Globe and Dome Reflector

NOTE: Photometric data was
developed using a 100 watt
clear high pressure sodium
lamp (9500 lumens). For other
clear lamps, use the following
conversion factors (multipliers):
Luminaire Lamp Conversion
Series
Watts Factor
VMVS
50
0.42
70
0.67
150
1.68

NOTE: Photometric data was
developed using a 175 watt
diffuse mercury vapor lamp
(8600 lumens). For other
diffuse lamps, use the following
conversion factors (multipliers):
Luminaire Lamp Conversion
Series
Watts Factor
VMVC
100
0.49
VMVM
70
0.65
100
0.91
175
1.63
Luminaire spacing ratio: 1.60

Luminaire spacing ratio: 2.0

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%

Effective Floor Cavity Reflectance 20%

% Reflectance
Eff. Ceil.
80

70

50

30

10
0
% Reflectance
Eff. Ceil.
80

70

50

30

10
0

734

STIBOINFO((CRH:66008com:3L:734))
CH0 0 3 L - 8

Wall
50
30
10
50
30
10
50
30
10
50
30
10
50
30
10
0
Wall
50
30
10
50
30
10
50
30
10
50
30
10
50
30
10
0

Room Cavity Ratio
1
2
3
.848
.709
.597
.796
.631
.509
.750
.566
.439
.818
.682
.576
.770
.611
.493
.726
.552
.428
.759
.632
.533
.720
.574
.464
.685
.521
.407
.706
.586
.493
.675
.538
.435
.645
.495
.386
.658
.544
.457
.632
.504
.408
.608
.469
.366
.581
.441
.340
Room Cavity Ratio
6
7
8
.384
.337
.299
.292
.249
.214
.226
.189
.154
.369
.325
.288
.283
.240
.203
.218
.182
.150
.341
.301
.266
.266
.225
.195
.209
.173
.143
.316
.277
.248
.249
.213
.182
.199
.163
.136
.292
.258
.223
.233
.200
.171
.188
.154
.128
.165
.133
.108

US: 1-866-764-5454

4
.508
.414
.341
.489
.402
.334
.451
.377
.318
.417
.354
.302
.385
.331
.286
.260

5
.437
.343
.271
.419
.331
.264
.389
.312
.253
.359
.291
.240
.331
.274
.227
.203

9
.272
.189
.132
.262
.183
.130
.243
.173
.124
.225
.161
.117
.209
.151
.110
.091

10
.238
.159
.103
.229
.156
.105
.214
.146
.099
.198
.136
.093
.134
.127
.087
.070

CAN: 1-800-265-0502

% Reflectance
Eff. Ceil.
80

70

50

30

10
0
% Reflectance
Eff. Ceil.
80

70

50

30

10
0

Wall
50
30
10
50
30
10
50
30
10
50
30
10
50
30
10
0
Wall
50
30
10
50
30
10
50
30
10
50
30
10
50
30
10
0

Room Cavity Ratio
1
2
3
.793
.682
.591
.753
.623
.522
.718
.572
.468
.775
.667
.580
.738
.611
.514
.705
.566
.463
.739
.637
.555
.709
.591
.498
.682
.550
.454
.707
.611
.532
.683
.572
.485
.660
.537
.445
.679
.588
.512
.658
.553
.471
.639
.525
.436
.622
.506
.418
Room Cavity Ratio
6
7
8
.403
.359
.320
.328
.285
.250
.275
.236
.199
.395
.352
.314
.324
.281
.247
.271
.233
.198
.379
.339
.303
.316
.274
.241
.298
.230
.196
.366
.325
.293
.309
.268
.235
.265
.226
.195
.353
.318
.282
.301
.264
.231
.282
.224
.193
.245
.208
.177

Copyright© 2006 Cooper Crouse-Hinds

4
.515
.440
.382
.505
.435
.379
.483
.422
.374
.484
.411
.388
.446
.400
.362
.343

5
.453
.376
.319
.442
.370
.316
.426
.362
.313
.409
.352
.309
.394
.345
.304
.287

9
.291
.221
.174
.286
.219
.174
.276
.215
.172
.266
.209
.170
.257
.208
.168
.153

10
.253
.185
.142
.248
.185
.142
.241
.181
.140
.233
.177
.138
.225
.179
.136
.122

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0735-5 Name: 3L-735

100:
DATE: JAN 19 2006

35-150W LMV Series
®

Champ H.I.D. Luminaires
Medium Base

Time: 5:47:18 PM Operator: RB

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III
& Simultaneous Presence
(HPS 35, 50W)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66

3L

Application:

Options:

LMV series Champ® luminaires are used:
ɀ in applications involving low luminaire
mounting heights or restricted mounting
space or where luminaire weight is a factor
ɀ in areas in which ignitible concentrations of
flammable gases or vapors will be present
only due to abnormal, unusual, or accidental
conditions
ɀ where combustible dusts are present
ɀ where combustible dusts and flammable
vapors are present simultaneously
ɀ in elevated ambient temperatures often
found in industrial applications
ɀ in marine applications where water spray
and corrosive atmospheres are
considerations
ɀ wherever the damaging effects of wind,
snow, sleet, or hot sun are found
ɀ in manufacturing plants, chemical,
petrochemical, and other industrial process
facilities, waste or sewage treatment facilities,
offshore or dockside installations, cold
storage facilities, parking garages or
wherever dust, dirt, water, vibration and
rough usage are a problem

The following special options are available
from the factory by adding suffix to luminaire
Cat. No.:
Suffix to be
Description
Added to Cat. No.
ɀ Restricted Breathing Construction . . . . S826
- Class I Division 2 & Zone 2
Suitability
- Cooler Operating Temperatures
(T-Numbers)
ɀ Certified for IEC Zone 2 . . . . . . . . . . S826TB
- Furnished with terminal block,
crimp terminals and dedicated
voltage ballasts (no MT, DT, or TT)
ɀ Fused – to protect ballast and capacitors
against abnormal line conditions . . . . . S658*
(Not for use in Canada)
ɀ Ballast-Gard TM starter cut-out switch –
prevents starter pulsing when lamp is
cycling or inoperative; prolongs ballast and
ignitor life. Available for use with 50-100W
HPS only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG
ɀ Factory assembled with H.I.D. lamps
installed for additional labor savings. . . . . . FA
ɀ Stainless steel insert - top hat with stainless
steel threaded insert to attach ballast housing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S806

Features:
ɀ Compact, lightweight design is ideal for low
mounting heights.
ɀ Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent resistance to
corrosion.
ɀ Seven mounting arrangements to suit any
lighting layout – pendant, flexible pendant,
ceiling, wall, straight stanchion, angle
stanchion, and quad-mount.
ɀ Wide range of lamp wattages to meet
specifiers needs: 35, 50, 70, 100 and 150 watt
(HPS); 70 and 100 watt (MH) medium base
lamps.
ɀ Hinged ballast housing for ease of
installation and maintenance.
ɀ All luminaires designed to perform in a
40°C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65°C.
ɀ Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in wet
and corrosive environments.
ɀ Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation.
ɀ Low ambient capability to –40°C.
ɀ Dome and 30° angle reflectors made of
bright white Krydon® material provide
superior reflectivity, with twist-on feature
requiring no tools or additional hardware. Will
not chip, peel, dent, rust, or corrode.
ɀ Grounding wire for safety.
ɀ Medium base lamp sockets.

Standard Materials:
ɀ Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%)
ɀ Exterior hardware – stainless steel
ɀ Reflectors (dome and angle) – Krydon
fiberglass-reinforced polyester material
ɀ Globes – heat and impact resistant,
internally fluted glass
ɀ Guards – copper-free aluminum

Standard Finishes:
ɀ Copper-free aluminum – epoxy powder
coat
ɀ Krydon material – high reflectance white
ɀ Stainless steel – natural

STIBOINFO((CRH:66008com:3L:735))

Accessories:

Electrical Ratings:

ɀ See pages 775 and 776 for complete listing

ɀ 120 volts, dual-tap (120/277刁), multi-tap刁
ɀ 35, 50, 70, 100, 150 watts HPS
ɀ 70 and 100 watts MH

* When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

Certifications and
Compliances:
ɀ NEC and CEC:
- Class I, Division 2, Groups A,B,C,D
- HPS 35W, 50W - Class II, Class III &
Simultaneous Presence (Class 1,
Division 2 and Class II)
- Class I Zone 2
ɀ IEC:
- Zone 2 Ex nR IIC
ɀ UL Standards:
- 844, 2279 Hazardous (Classified)
Locations
- 1598 Luminaires
- 1598A Marine Locations
ɀ CSA Standards
- C22.2 No. 137
ɀ IEC Standards
- 60079-15

US: 1-866-764-5454

CH0 0 3 L - 9

COLOR: CMYK

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

735

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0736-2 Name: 3L-736

3L

DATE: JAN 19 2006

Time: 5:47:19 PM Operator: RB

COLOR: CMYK

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div
2 & Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)

35-150W High
Pressure Sodium

ɀ

LMV Series Champ® H.I.D.
Luminaires Medium Base

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G; Cl. III
& Simultaneous Presence
(35W, 50W)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66

See Note 1 (to specify voltage), 2 and 3. For guards and other optics see LMV Luminaires - Ordering by Components section.
BASIC CATALOG NUMBER
Hub
Lamp
With G54 Globe and
Mounting Style
Size
Watts
P50 Guard
3⁄4
Pendant Mount
35
LMVS2A035GP
1
LMVS3A035GP
3⁄4
50
LMVS2A050GP
1
LMVS3A050GP
3⁄4
70
LMVS2A070GP
1
LMVS3A070GP
3⁄4
100
LMVS2A100GP
1
LMVS3A100GP
3⁄4
150
LMVS2A150GP
1
LMVS3A150GP
3⁄4
Flexible Pendant Mount
35
LMVS2HA035GP
3⁄4
50
LMVS2HA050GP
3⁄4
70
LMVS2HA070GP
3⁄4
100
LMVS2HA100GP
3⁄4
150
LMVS2HA150GP

3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
3⁄4
3⁄4
3⁄4
3⁄4

35

35
50
70
100
150

LMVS2C035GP
LMVS3C035GP
LMVS2C050GP
LMVS3C050GP
LMVS2C070GP
LMVS3C070GP
LMVS2C100GP
LMVS3C100GP
LMVS2C150GP
LMVS3C150GP
LMVS2TW035GP
LMVS3TW035GP
LMVS2TW050GP
LMVS3TW050GP
LMVS2TW070GP
LMVS3TW070GP
LMVS2TW100GP
LMVS3TW100GP
LMVS2TW150GP
LMVS3TW150GP
LMVS25Q035GP
LMVS25Q050GP
LMVS25Q070GP
LMVS25Q100GP
LMVS25Q150GP

Stanchion Mount
25° Angle

11⁄2
11⁄2
11⁄2
11⁄2
11⁄2

35
50
70
100
150

LMVSJ035GP
LMVSJ050GP
LMVSJ070GP
LMVSJ100GP
LMVSJ150GP

Stanchion Mount
Straight

11⁄2
11⁄2
11⁄2
11⁄2
11⁄2

35
50
70
100
150

LMVSP035GP
LMVSP050GP
LMVSP070GP
LMVSP100GP
LMVSP150GP

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

Quad-Mount Pendant,
Adjustable Thru-Feed,
25° Angle, 121⁄2° Angle

Voltage
Suffix

STIBOINFO((CRH:66008com:3L:736))
CH0 3 L - 1 0

70
100
150
35
50
70
100
150

Standard Voltage Ballasts - 60Hz
NEC/UL

1.

736

50

Multi Tap
/MT

Dual Tap
/DT

120V
/120

480V
/480

CEC/CSA (cUL)
Tri Tap
/TT

Dual Tap
/DT

2. 150W HPS Luminaires, 55V Lamps is Standard . 50W HPS luminaire is dual-tap only.
3. Options - Add the Required Options Suffixes from page 735, In Alpha-numeric Order
 – available with Lightning Service TMdelivery. See Section G for complete details

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

120V
/120

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0737-2 Name: 3L-737

DATE: JAN 19 2006

70-100W
Metal Halide
LMV Series Champ® H.I.D.
Luminaires Medium Base

Time: 5:47:21 PM Operator: RB

COLOR: CMYK

ɀ

ɀ

ɀ

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div 2 & Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)

TCP: 15001

Typedriver Name: TS name csm no.: 100

Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

See Note 1 (to specify voltage), 2 and 3. For guards and other optics see LMV Luminaires - Ordering by Components section.
BASIC CATALOG NUMBER
Hub
Lamp
With G54 Globe and
Mounting Style
Size
Watts
P50 Guard
3⁄4
Pendant Mount
70
LMVM2A070GP
1
LMVM3A070GP
3⁄4
100
LMVM2A100GP
1
LMVM3A100GP

Flexible Pendant Mount

3⁄4

70
100

LMVM2HA070GP
LMVM2HA100GP

3⁄4
1
3⁄4
1

70

LMVM2C070GP
LMVM3C070GP
LMVM2C100GP
LMVM3C100GP

3⁄4
1
3⁄4
1

70

Stanchion Mount
25° Angle

11⁄2
11⁄2

70
100

LMVMJ070GP
LMVMJ100GP

Stanchion Mount
Straight

11⁄2
11⁄2

70
100

LMVMP070GP
LMVMP100GP

3⁄4

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

100

100

LMVM2TW070GP
LMVM3TW070GP
LMVM2TW100GP
LMVM3TW100GP

Standard Voltage Ballasts - 60Hz
NEC/UL

1.
Voltage
Suffix

Multi Tap
/MT

120V
/120

480V
/480

CEC/CSA (cUL)
Tri Tap
/TT

120V
/120

2. Options - Add the Required Options Suffixes from page 735 in Alpha-numeric Order
3. 70W Ballast not available in 480V.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:737))
CH0 3 L - 1 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

737

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0738-1 Name: 3L-738

3L

100:
DATE: JAN 19 2006

Time: 5:47:22 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

LMV Luminaires Ordering by Components

LMV luminaires are available in components
A complete luminaire consists of:
I.
Champ Cover (mounting module)
II.
LMV Ballast Housing - Include voltage and required option(s)
III.
Globe, Guard, Reflector

I. Champ Cover (Mounting Module):
Type
Pendant
Flexible Pendant
Ceiling
Wall
Stanchion - 25 Degree Angle
Stanchion - Straight
Quad-Mount

Conduit
3⁄4

1
3⁄4
3⁄4
1
3⁄4
1
11⁄2
11⁄2
3⁄4

Cat. No.
APM2
APM3
HPM2
CM2
CM3
TWM2
TWM3
JM5
PM5
QM25

II. Ballast Housings: Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Type
High Pressure Sodium

Metal Halide

Lamp
Watts
35
50
70
100
150
70
100

Catalog Number
LMVS035/MT
LMVS050/MT
LMVS070/MT
LMVS100/MT
LMVS150/MT LX
LMVM070/MT
LMVM100/MT

III. Globe, Guards and Reflectors:
Type
Globe
Globe Guard
Globe Reflector-Dome
Globe Reflector-Angle

738

STIBOINFO((CRH:66008com:3L:738))
CH0 3 L - 1 5

Catalog Number
G54
P50
RD636
RA636

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0739-1 Name: 3L-739

100:
DATE: JAN 19 2006

Time: 5:47:23 PM Operator: JB

35-150W LMV Series

COLOR: CMYK

TCP: 15001

Family Tree

Typedriver Name: TS name csm no.: 100

3L

®

Champ H.I.D. Luminaires

 – available with Lightning Service TM delivery. See Section G for complete details.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:739))
CH0 3 L - 1 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

739

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0740-16 Name: 3L-740

100:
DATE: JAN 19 2006

Time: 5:47:24 PM Operator: GK COLOR: CMYK

Typedriver Name: TS name csm no.: 100

Temperature Performance Data

35-150W LMV Series

3L

TCP: 15001

Champ® H.I.D Luminaires

RATED
AMBIENT
°C

LAMP

Cat. No.
LMVS35
LMVS35
LMVS35
LMVS50
LMVS50
LMVS50
LMVS70
LMVS70
LMVS100
LMVS100
LMVM70
LMVM70
LMVM100
LMVM150

Wattage

Type

35
35
35
50
50
50
70
70
100
100
70
70
100
150

HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
MH
MH
MH
HPS

40
55
65
40
55
65
40
55
40
50
40
55
40
40

CLASS I,
DIVISION 2
Globe (G54)
w/ or w/o
Reflector
(RA636 or
RD636)*
T3A
T3
T3
T2D
T2C
T2C
T2B
T2B
T2
—
T2B
T2B
—
T1 350°C

CLASS II, DIVISION 1

CLASS I, ZONE 2

Group

Globe (G54)
w/ or w/o
Reflector
(RA636 or
RD636)

Simultaneous
Presence
Class I, Div. 2
Class II, Div. 1

Restricted
Breathing
Suffix
S826 w/
Globe (G54)

Factory
Sealed
Suffix
S865 AEx
nA nR II

Supply
Wire
Suitable
for °C

EFG
EFG
EFG
EFG
—
—
—
—
—
—
—
—
—
—

T4A
T4
T3C
T3C
—
—
—
—
—
—
—
—
—
—

T2D
T2C
T2C
T2B
—
—
—
—
—
—
—
—
—
—

T6
T5
T4
T5
T4
T4
T4
T4
T4
T3
T4
T4
T3
—

T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
—

N/A
75
85
N/A
75
85
75
85
85
90
75
85
85
85

The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires are listed to UL 844. UL
844 specifies how the temperatures are measured.
The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring temperatures. Since NEC® 501.1
states that equipment “...for use in Class I, Zone 0, 1 or 2 locations shall be permitted in Class I, Division 2 locations...” then these luminaires are suitable for Class I,
Division 2 but with lower temperature ratings. They also have the advantage of meeting the more rigorous mechanical tests of UL 844.

740

STIBOINFO((CRH:66008com:3L:740))
CH0 3 L - 1 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0741-1 Name: 3L-741

DATE: JAN 19 2006

Time: 5:47:25 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Dimensions and Weights

35-150W LMV Series

3L

®

Champ H.I.D. Luminaires

Dimensions
Pendant Mount

Top View

Wall Mount

Ceiling Mount

Quad-Mount
Luminaire with Globe, Guard, Reflectors

Straight Stanchion Mount

25° Angle Stanchion Mount

Luminaire Net Weights:
Luminaire Lamp
Series
Watts
LMVS

LMVM

35
50
70
100
150
70
100

Luminaire
with Globe,
Guard (lbs.)
71⁄4
73⁄4
81⁄4
83⁄4
91⁄4
9
9

Add for mounting modules (lbs.)
Wall
Pendant
11⁄4

41⁄2

Flexible
Pendant

11⁄2

Angle
Stanchion

31⁄2

Ceiling

23⁄4

Straight
Stanchion

41⁄2

QuadMount

31⁄2

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:741))
CH0 3 L - 1 2

CAN: 1-800-265-0502

Add for reflectors (lbs.):
Dome 1.0
30° Angle 1.0
Deduct for luminaire without guard (lbs.):
P50 Guard 1⁄2

Copyright© 2006 Cooper Crouse-Hinds

741

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0742-2 Name: 3L-742

100:
DATE: JAN 19 2006

Time: 5:47:26 PM Operator: RB

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

35-150W LMV Series

3L

COLOR: CMYK

Champ® H.I.D. Luminaires

Lamp: 100W/E-17 high pressure sodium (HPS)
Total bare lamp lumens: 9500
To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689.
NOTE: All data provided is for high pressure sodium luminaires with 100W/E-17 clear lamps. Use
conversion factors (multipliers) shown below for other lamp types and wattages. Consult Cooper
Crouse-Hinds for additional photometric data on any Champ Series luminaire.

Luminaire with Globe and Dome Reflector
Multipliers (for use with
candlepower curves only).
ConLuminaire Lamp version
Series
Watts Factors
LMVS
35
0.24
50
0.42
70
0.67
150
1.68

Isofootcandle Chart: Luminaire with Globe and Dome
Reflector

Luminaire spacing ratio: 2.0

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Cell
80

70

50

30

10
0
% Reflectance
Eff. Cell
80

70

50

30

10
0

742

STIBOINFO((CRH:66008com:3L:742))
CH0 3 L - 1 3

Wall
50
30
10
50
30
10
50
30
10
50
30
10
50
30
10
0

Room Cavity Ratio
1
2
3
.722
.628
.545
.691
.579
.487
.663
.537
.441
.705
.613
.534
.676
.568
.479
.650
.531
.436
.671
.585
.511
.647
.548
.464
.627
.514
.426
.641
.560
.489
.623
.529
.450
.605
.501
.416
.614
.537
.470
.598
.510
.436
.584
.488
.407
.568
.471
.391

4
.473
.408
.358
.463
.403
.355
.442
.390
.349
.424
.379
.342
.407
.367
.335
.319

5
.413
.346
.296
.403
.340
.293
.387
.332
.289
.371
.322
.284
.356
.341
.279
.263

Wall
50
30
10
50
30
10
50
30
10
50
30
10
50
30
10
0

Room Cavity Ratio
6
7
8
.366
.324
.288
.300
.259
.225
.253
.215
.180
.358
.318
.282
.295
.255
.223
.249
.212
.179
.343
.305
.271
.288
.248
.217
.246
.209
.177
.330
.292
.261
.280
.243
.210
.242
.205
.175
.317
.282
.251
.272
.237
.206
.238
.202
.172
.223
.187
.158

9
.261
.199
.156
.256
.196
.156
.246
.192
.154
.237
.186
.152
.228
.182
.149
.136

10
.226
.165
.127
.221
.165
.126
.214
.161
.124
.206
.157
.122
.199
.152
.120
.107

US: 1-866-764-5454

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with Globe and 30°
Angle Reflector

Isofootcandle charts show illumination in footcandles on work plane 10
feet below light center. Multiply by factor shown to convert to other
mounting heights.
Height (Ft.)
Factor
Height (Ft.)
Factor
6
2.78
14
0.51
8
1.56
16
0.39
12
0.70

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0743-9 Name: 3L-743

100:
DATE: JAN 19 2006

50-250W DMV Series
®

Champ
H.I.D. Lighting Luminaires
Enclosed & Gasketed

Time: 5:47:27 PM Operator: RB

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III
& Simultaneous Presence
(175W max)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66

3L

Application:

Options:

DMV series Champ luminaires are used:
ɀ in applications made hazardous by the
presence of combustible dusts
ɀ in areas in which ignitible concentrations of
flammable gases or vapors will be present
only due to abnormal, unusual, or accidental
conditions
ɀ in marine applications where water spray
and corrosive atmospheres are
considerations
ɀ in areas where combustible dusts and
flammable vapors are present simultaneously
ɀ in elevated ambient temperatures often
found in industrial applications
ɀ in installations where moisture, dirt, dust,
vibration, corrosion and rough usage are
problems
ɀ wherever the damaging effects of wind,
snow, sleet, or hot sun are found
ɀ in grain handling, storage and processing
plants, coal preparation plants, coal
conveying areas, food processing plants,
manufacturing plants, refineries, chemical,
petrochemical, and other industrial process
facilities, waste or sewage treatment facilities,
offshore, dockside, and harbor installations,
and other heavy industrial applications

The following special options are available
from the factory by adding suffix to luminaire
Cat. No.:
Suffix to be
Description
Added to Cat. No.
ɀ Restricted Breathing Construction. . . . S826
- Class I Division 2 & Zone 2
Suitabilty
- Cooler Operating Temperatures
(T-Numbers)

Features:
ɀ Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent resistance to
corrosion.
ɀ Seven mounting arrangements to suit any
lighting layout – pendant, flexible pendant,
ceiling, wall bracket, angle stanchion, straight
stanchion, and quad-mount.
ɀ Wide range of light sources and wattages
to meet specifiers needs: 50, 70, 100, 150
watt high pressure sodium (HPS); 100, 175,
250 watt mercury vapor (MV); 70, 100, 175,
250 watt metal halide.
ɀ Hinged ballast housing for ease of
installation and maintenance.
ɀ All luminaires designed to perform in a 40° C
ambient temperature. Selected luminaires are
suitable for ambient temperatures up to 65° C.
ɀ Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in wet
and corrosive environments.
ɀ Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation.
ɀ Low ambient capability to (–40 ° C.)
ɀ Dome and 30° angle reflectors made of
bright white Krydon® material provide
superior reflectivity, with twist-on feature
requiring no tools or additional hardware. Will
not chip, peel, dent, rust, or corrode.
ɀ Mogul base porcelain lamp socket.
ɀ Stainless steel open bottom guard permits
direct access to the globe for easy relamping.
DMV Series
* Now available with Champ Induction
Lighting System. See Section 5L.

ɀ Grounding wire for safety.
ɀ Ballasts available in voltages of 120, 208,
240, 277, 347, 480, 600 and multi-tap.刁

Standard Materials:
ɀ Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1% copper)
ɀ Guard and exterior hardware – stainless
steel
ɀ Reflectors (dome and angle) – Krydon
fiberglass-reinforced polyester material
ɀ Globes – heat and impact resistant,
internally fluted glass

Standard Finishes:
ɀ Copper-free aluminum – epoxy powder
coat
ɀ Krydon material – high reflectance white
ɀ Stainless steel – natural

Electrical Ratings:
ɀ 120, multi-tap刁 (120, 208, 240 and 277),
tri-tap (120, 208, 347) 208, 240, 277, 347, 480,
600 volts
ɀ 50-250W HPS; 100-250W† MV; 70-250W†
MH

Certifications and
Compliances:
ɀ NEC & CEC:
- Class I, Division 2, Groups A,B,C,D
- 175W max - Class II, Class III &
Simultaneous Presence (Class I,
Division 2 and Class II)
- Class I Zone 2
ɀ IEC:
- Zone 2 Ex nR IIC
ɀ UL Standards:
- 844, 2279 Hazardous (Classified)
Locations
- 1598 Luminaires
- 1598A Marine Locations
ɀ CSA Standards
- C22.2 No. 137
ɀ IEC Standards
- 60079-15

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:743))
CH0 3 L - 1 4

COLOR: CMYK

CAN: 1-800-265-0502

ɀ Restricted Breathing/Non-Sparking. . . S865
- Class I Division 2 & Zone 2
- Provides T3 code without conduit
or cable seals
ɀ Certified for IEC Zone 2 . . . . . . . . . . S826TB
- Furnished with terminal block,
crimp terminals and dedicated
voltage ballasts (no MT, DT or TT)
ɀ Fused – to protect ballast and
capacitors against abnormal line
conditions . . . . . . . . . . . . . . . . . . . . . . . . . S658*
(Not for use in Canada)
ɀ Ballast-Gard TM starter cut-out switch
– prevents starter pulsing when lamp
is cycling or inoperative; prolongs
ballast and ignitor life. Available for
use with 50-150W LX HPS only . . . . . . . . . . BG
ɀ Instant restrike – enables a hot HPS
lamp to immediately restrike after a
momentary loss of arc due to voltage
fluctuation or power outage. It has no
effect on the warm-up period of cold
lamps. Available for use with 50-150W
LX HPS only . . . . . . . . . . . . . . . . . . . . . . . . . . . IR
ɀ Quartz auxiliary lighting – comes to
full brightness immediately and
remains lit until the HID lamp attains
60-70% of full illumination. For nonhazardous locations only. (Note: QTZ
lamp not included; use 100W single
ended lamp – Q100DC, Q100CL/DC, or
100Q/CL/DC) Consult factory for top-hat
limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . QTZ
ɀ Factory assembled with H.I.D. lamps
installed for additional labor savings. . . . . . FA
ɀ TEFLON® coated globe-for additional
protection against breakage. For use with
50-150W HPS, 70-175W MH and 100-175W
MV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S808
NOTE: Some T-numbers (operating
temperatures) change. See ‘‘Temperature
Performance Data’’ section.
ɀ Stainless steel insert - top hat with stainless
steel threaded insert to attach ballast housing
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S806
(Note: BG and IR options cannot be used
together. IR and QTZ options cannot be used
together.)

Accessories:
ɀ See pages 775 and 776 for complete
listing.
ɀ See page 749 for family tree.
ɍTEFLON is a registered trademark of E.I. duPont Co.

* When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

Copyright© 2006 Cooper Crouse-Hinds

743

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0744-2 Name: 3L-744

3L

DATE: JAN 19 2006

Time: 5:47:28 PM Operator: RB

COLOR: CMYK

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2 (Suffix
S826TB)

50-150W High
Pressure Sodium

ɀ

DMV Series
Champ® H.I.D. Luminaires

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G; Cl. III &
Simultaneous Presence
ɀ Marine & Wet Locations
ɀ 3,3R, 4,4X; IP66

See notes 1 (to specify voltage) 2 and 3. For guards and other optics see DMV Luminaires - Ordering by Components section.
BASIC CATALOG NUMBER
Mounting
Hub
Lamp
With G303 Globe
With GR305 Glass
Style
Size
Watts
and P33 Guard
Refractor
3⁄4
Pendant Mount
50
DMVS2A050GP
DMVS2A050GR305
1
DMVS3A050GP
DMVS3A050GR305
3⁄4
70
DMVS2A070GP
DMVS2A070GR305
1
DMVS3A070GP
DMVS3A070GR305
3⁄4
100
DMVS2A100GP
DMVS2A100GR305
1
DMVS3A100GP
DMVS3A100GR305
3⁄4
150
DMVS2A150GP
DMVS2A150GR305
1
DMVS3A150GP
DMVS3A150GR305
3⁄4

Flexible Pendant
Mount

50
70
100
150

DMVS2HA050GP
DMVS2HA070GP
DMVS2HA100GP
DMVS2HA150GP

DMVS2HA050GR305
DMVS2HA070GR305
DMVS2HA100GR305
DMVS2HA150GR305

3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1

50

DMVS2C050GP
DMVS3C050GP
DMVS2C070GP
DMVS3C070GP
DMVS2C100GP
DMVS3C100GP
DMVS2C150GP
DMVS3C150GP

DMVS2C050GR305
DMVS3C050GR305
DMVS2C070GR305
DMVS3C070GR305
DMVS2C100GR305
DMVS3C100GR305
DMVS2C150GR305
DMVS3C150GR305

3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1

50

DMVS2TW050GP
DMVS3TW050GP
DMVS2TW070GP
DMVS3TW070GP
DMVS2TW100GP
DMVS3TW100GP
DMVS2TW150GP
DMVS3TW150GP

DMVS2TW050GR305
DMVS3TW050GR305
DMVS2TW070GR305
DMVS3TW070GR305
DMVS2TW100GR305
DMVS3TW100GR305
DMVS2TW150GR305
DMVS3TW150GR305

Quad-Mount Pendant,
Adjustable Thru-Feed,
25° Angle, 121⁄2° Angle

3⁄4

3⁄4

50
70
100
150

DMVS25Q050GP
DMVS25Q070GP
DMVS25Q100GP
DMVS25Q150GP

DMVS25Q050GR305
DMVS25Q070GR305
DMVS25Q100GR305
DMVS25Q150GR305

Stanchion Mount
25° Angle

11⁄2
11⁄2
11⁄2
11⁄2

50
70
100
150

DMVSJ050GP
DMVSJ070GP
DMVSJ100GP
DMVSJ150GP

DMVSJ050GR305
DMVSJ070GR305
DMVSJ100GR305
DMVSJ150GR305

Stanchion Mount
Straight

11⁄2
11⁄2
11⁄2
11⁄2

50
70
100
150

DMVSP050GP
DMVSP070GP
DMVSP100GP
DMVSP150GP

DMVSP050GR305
DMVSP070GR305
DMVSP100GR305
DMVSP150GR305

3⁄4
3⁄4
3⁄4

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

3⁄4
3⁄4

1.
Voltage
Suffix

Multi Tap
/MT

70
100
150

70
100
150

Standard Voltage Ballasts - 60Hz
NEC/UL
Dual Tap
120V
480V
/DT
/120
/480

Tri Tap
/TT

CEC/CSA (cUL)
Dual Tap
/DT

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts

EXPORT

Voltage
208V CWI
240V CWI
480V CWI
600V CWI
220V 60Hz
220V 50Hz
Suffix
/208CWI
/240CWI
/480CWI
/600CWI
/220
/220 50
2. 150W HPS Luminaires, 55V Lamps is Standard, for 100V lamps - Add suffix ‘‘CE’’. 50W HPS luminaire is dual-tap only.
3. Options - Add the Required Options Suffixes from page 743, In Alpha-numeric order.
 – available with Lightning Service TM delivery. See Section G for details.

744

STIBOINFO((CRH:66008com:3L:744))
CH0 3 L - 2 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

120V
/120

230V 50Hz
/230 50

240V 50Hz
/240 50

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0745-3 Name: 3L-745

DATE: JAN 19 2006

150-250W Pulse Start
Metal Halide
DMV Series
Champ® H.I.D. Luminaires

Time: 5:47:30 PM Operator: RB

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III &
Simultaneous Presence
(175W max)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66

3L

See Notes 1 (to specify voltage) and 2. For Guards and other optics see DMV Luminaires - Ordering by Components Section
BASIC CATALOG NUMBER

150
175
200

With G303 Globe
With GR305 Glass
and P33 Guard
Refractor
Cat. No.
Cat. No.
DMVM2A150GP-S828
DMVM2A150GR305-S828
DMVM3A150GP-S828
DMVM3A150GR305-S828
DMVM2A175GP-S828
DMVM2A175GR305-S828
DMVM3A175GP-S828
DMVM3A175GR305-S828
DMVM2A200GP-S828
DMVM2A200GR305-S828
DMVM3A200GP-S828
DMVM3A200GR305-S828
(Use Ceiling Mount) - Ceiling Mount has pendant conduit hub
(Use Ceiling Mount)
DMVM2HA150GP-S828
DMVM2HA150GR305-S828
DMVM2HA175GP-S828
DMVM2HA175GR305-S828
DMVM2HA200GP-S828
DMVM2HA200GR305-S828

3⁄4

250

(Use Ceiling Mount)

3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1

150

DMVM2C150GP-S828
DMVM3C150GP-S828
DMVM2C175GP-S828
DMVM3C175GP-S828
DMVM2C200GP-S828
DMVM3C200GP-S828
DMVM2C250GP-S828
DMVM3C250GP-S828

DMVM2C150GR305-S828
DMVM3C150GR305-S828
DMVM2C175GR305-S828
DMVM3C175GR305-S828
DMVM2C200GR305-S828
DMVM3C200GR305-S828
DMVM2C250GR305-S828
DMVM3C250GR305-S828

3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1

150

DMVM2TW150GP-S828
DMVM3TW150GP-S828
DMVM2TW175GP-S828
DMVM3TW175GP-S828
DMVM2TW200GP-S828
DMVM3TW200GP-S828
DMVM2TW250GP-S828
DMVM3TW250GP-S828

DMVM2TW150GR305-S828
DMVM3TW150GR305-S828
DMVM2TW175GR305-S828
DMVM3TW175GR305-S828
DMVM2TW200GR305-S828
DMVM3TW200GR305-S828
DMVM2TW250GR305-S828
DMVM3TW250GR305-S828

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
121⁄2° Angle

3⁄4

3⁄4

150
175
200
250

DMVM25Q150GP-S828
DMVM25Q175GP-S828
DMVM25Q200GP-S828
DMVM25Q250GP-S828

DMVM25Q150GR305-S828
DMVM25Q175GR305-S828
DMVM25Q200GR305-S828
DMVM25Q250GR305-S828

Stanchion Mount
25° Angle

11⁄2
11⁄2
11⁄2
11⁄2

150
175
200
250

DMVMJ150GP-S828
DMVMJ175GP-S828
DMVMJ200GP-S828
DMVMJ250GP-S828

DMVMJ150GR305-S828
DMVMJ175GR305-S828
DMVMJ200GR305-S828
DMVMJ250GR305-S828

Stanchion Mount
Straight

11⁄2
11⁄2
11⁄2
11⁄2

150
175
200
250

DMVMP150GP-S828
DMVMP175GP-S828
DMVMP200GP-S828
DMVMP250GP-S828

DMVMP150GR305-S828
DMVMP175GR305-S828
DMVMP200GR305-S828
DMVMP250GR305-S828

Mounting
Style
Pendant Mount

Flexible Pendant
Mount

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

Hub
Size
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
3⁄4
3⁄4

Lamp
Watts
150
175
200
250

175
200
250

175
200
250

3⁄4
3⁄4

1.
Voltage
Suffix

Multi Tap
/MT

- Ceiling Mount has pendant conduit hub

Standard Voltage Ballasts - 60Hz
NEC/UL
120V
480V
/120
/480

CEC/CSA (cUL)
Tri Tap
/TT

120V
/120

Optional Voltage Ballasts - 50 or 60Hz
EXPORT
Voltage
220V 60Hz
220V 50Hz
Suffix
/220
/220 50
2. Options - Add the Required Options Suffixes for page 743 in Alpha-numeric Order

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:745))
CH0 3 L - 2 4

CAN: 1-800-265-0502

230V 50Hz
/230 50

Copyright© 2006 Cooper Crouse-Hinds

240V 50Hz
/240 50

745

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0746-2 Name: 3L-746

3L

DATE: JAN 19 2006

Time: 5:48:34 PM Operator: RB

COLOR: CMYK

TCP: 15001

ɀ

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)

70-250W Metal
Halide

Cl. II Groups E, F, G, Cl. III &
Simultaneous Presence
(175W max)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66

ɀ

DMV Series
Champ® H.I.D. Luminaires

Typedriver Name: TS name csm no.: 100

See Note 1 (to specify voltage), 2 and 3. For Guards and other optics see DMV Luminaires - Ordering by Components Section
BASIC CATALOG NUMBER

70
100
175

With G303 Globe
and P33 Guard
Cat. No.
DMVM2A070GP
DMVM3A070GP
DMVM2A100GP
DMVM3A100GP
DMVM2A175GP
DMVM3A175GP
(Use Ceiling Mount)
(Use Ceiling Mount)
DMVM2HA070GP
DMVM2HA100GP
DMVM2HA175GP

3⁄4

250

(Use Ceiling Mount)

3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1

70

DMVM2C070GP
DMVM3C070GP
DMVM2C100GP
DMVM3C100GP
DMVM2C175GP
DMVM3C175GP
DMVM2C250GP
DMVM3C250GP

DMVM2C070GR305
DMVM3C070GR305
DMVM2C100GR305
DMVM3C100GR305
DMVM2C175GR305
DMVM3C175GR305
DMVM2C250GR305
DMVM3C250GR305

3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1

70

DMVM2TW070GP
DMVM3TW070GP
DMVM2TW100GP
DMVM3TW100GP
DMVM2TW175GP
DMVM3TW175GP
DMVM2TW250GP
DMVM3TW250GP

DMVM2TW070GR305
DMVM3TW070GR305
DMVM2TW100GR305
DMVM3TW100GR305
DMVM2TW175GR305
DMVM3TW175GR305
DMVM2TW250GR305
DMVM3TW250GR305

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
121⁄2° Angle

3⁄4

3⁄4

70
100
175
250

DMVM25Q070GP
DMVM25Q100GP
DMVM25Q175GP
DMVM25Q250GP

DMVM25Q070GR305
DMVM25Q100GR305
DMVM25Q175GR305
DMVM25Q250GR305

Stanchion Mount
25° Angle

11⁄2
11⁄2
11⁄2
11⁄2

70
100
175
250

DMVMJ070GP
DMVMJ100GP
DMVMJ175GP
DMVMJ250GP

DMVMJ070GR305
DMVMJ100GR305
DMVMJ175GR305
DMVMJ250GR305

Stanchion Mount
Straight

11⁄2
11⁄2
11⁄2
11⁄2

70
100
175
250

DMVMP070GP
DMVMP100GP
DMVMP175GP
DMVMP250GP

DMVMP070GR305
DMVMP100GR305
DMVMP175GR305
DMVMP250GR305

Mounting
Style
Pendant Mount

Hub
Size
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
3⁄4
3⁄4

Flexible Pendant
Mount

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

Lamp
Watts
70
100
175
250

100
175
250

100
175
250

3⁄4
3⁄4

1.
Voltage
Suffix

Multi Tap
/MT

With GR305 Glass
Refractor
Cat. No.
DMVM2A070GR305
DMVM3A070GR305
DMVM2A100GR305
DMVM3A100GR305
DMVM2A175GR305
DMVM3A175GR305
- Ceiling Mount has pendant conduit hub

DMVM2HA070GR305
DMVM2HA100GR305
DMVM2HA175GR305
- Ceiling Mount has pendant conduit hub

Standard Voltage Ballasts - 60Hz
NEC/UL
120V
480V
/120
/480

CEC/CSA (cUL)
Tri Tap
/TT

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts – 175W and
250W MH only
Voltage
Suffix

746

STIBOINFO((CRH:66008com:3L:746))
CH0 3 L - 2 4

2.
3.

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

EXPORT
220V 60Hz
/220

220V 50Hz
/220 50

70W Ballast not available in 480V
Options - Add the required options suffixes from page 743, in Alpha-numeric order.

US: 1-866-764-5454

CAN: 1-800-265-0502

120V
/120

Copyright© 2006 Cooper Crouse-Hinds

230V 50Hz
/230 50

240V 50Hz
/240 50

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0747-3 Name: 3L-747

DATE: JAN 19 2006

Time: 5:48:36 PM Operator: JB

ɀ

100-250W Mercury
Vapor

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

DMV Series
Champ® H.I.D. Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III &
Simultaneous Presence
(175W max)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66

3L

See Note 1 (to specify voltage) and 2. For Guards and other optics see DMV Luminaires - Ordering by Components Section
BASIC CATALOG NUMBER
With G303 Globe
and P33 Guard
Cat. No.
DMVC2A100GP
DMVC3A100GP
DMVC2A175GP
DMVC3A175GP
DMVC2A250GP
DMVC3A250GP

With GR305 Glass
Refractor
Cat. No.
DMVC2A100GR305
DMVC3A100GR305
DMVC2A175GR305
DMVC3A175GR305
DMVC2A250GR305
DMVC3A250GR305

100
175
250

DMVC2HA100GP
DMVC2HA175GP
DMVC2HA250GP

DMVC2HA100GR305
DMVC2HA175GR305
DMVC2HA250GR305

3⁄4
1
3⁄4
1
3⁄4
1

100

DMVC2C100GP
DMVC3C100GP
DMVC2C175GP
DMVC3C175GP
DMVC2C250GP
DMVC3C250GP

DMVC2C100GR305
DMVC3C100GR305
DMVC2C175GR305
DMVC3C175GR305
DMVC2C250GR305
DMVC3C250GR305

3⁄4
1
3⁄4
1
3⁄4
1

100

DMVC2TW100GP
DMVC3TW100GP
DMVC2TW175GP
DMVC3TW175GP
DMVC2TW250GP
DMVC3TW250GP

DMVC2TW100GR305
DMVC3TW100GR305
DMVC2TW175GR305
DMVC3TW175GR305
DMVC2TW250GR305
DMVC3TW250GR305

Quad-Mount Pendant,
Adjustable Thru-Feed,
25° Angle, 121⁄2° Angle

3⁄4
3⁄4

100
175
250

DMVC25Q100GP
DMVC25Q175GP
DMVC25Q250GP

DMVC25Q100GR305
DMVC25Q175GR305
DMVC25Q250GR305

Stanchion Mount
25° Angle

11⁄2
11⁄2
11⁄2

100
175
250

DMVCJ100GP
DMVCJ175GP
DMVCJ250GP

DMVCJ100GR305
DMVCJ175GR305
DMVCJ250GR305

Stanchion Mount
Straight

11⁄2
11⁄2
11⁄2

100
175
250

DMVCP100GP
DMVCP175GP
DMVCP250GP

DMVCP100GR305
DMVCP175GR305
DMVCP250GR305

Mounting
Style
Pendant Mount

Flexible Pendant
Mount

Hub
Size
3⁄4
1
3⁄4
1
3⁄4
1

Lamp
Watts
100
175
250

3⁄4
3⁄4
3⁄4

Ceiling Mount ThruFeed

Wall Mount
Thru-Feed

175
250

175
250

3⁄4

1.
Voltage
Suffix

Multi Tap
/MT

Voltage
Suffix
2.

STIBOINFO((CRH:66008com:3L:747))

CEC/CSA (cUL)
Tri Tap
/TT

Optional Voltage Ballasts - 50 or 60Hz
EXPORT
220V 60Hz
220V 50Hz
230V 50Hz
/220
/220 50
/230 50

120V
/120

240V 50Hz
/240 50

Options - Add the required options suffixes from page 743, in Alpha-numeric order.

US: 1-866-764-5454

CH0 3 L - 1 6

Standard Voltage Ballasts - 60Hz
NEC/UL
120V
480V
/120
/480

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

747

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0748-1 Name: 3L-748

3L

100:
DATE: JAN 19 2006

Time: 5:48:38 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

DMV Luminaires Ordering by Components

DMV luminaires are available in components
A complete luminaire consists of:
I.
Champ Cover (mounting module)
II.
DMV Ballast Housing - Include voltage and required option(s)
III.
Globe, Refractor, Guard, Reflector

I. Champ Cover (Mounting Module):
Type
Pendant
Flexible Pendant
Ceiling
Wall
Stanchion - 25 Degree Angle
Stanchion - Straight
Quad-Mount

Conduit
3⁄4

1
3⁄4
3⁄4
1
3⁄4
1
11⁄2
11⁄2
3⁄4

Cat. No.
APM2
APM3
HPM2
CM2
CM3
TWM2
TWM3
JM5
PM5
QM25

II. Ballast Housings. Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Type
High Pressure Sodium

Metal Halide

Mercury Vapor

Lamp
Watts
50
70
100
150
250
70
100
175
250
100
175
250

Catalog Number
DMVS050/MT
DMVS070/MT
DMVS100/MT
DMVS150/MT LX
DMVS250/MT
DMVM070/MT
DMVM100/MT
DMVM175/MT
DMVM250/MT
DMVC100/MT
DMVC175/MT
DMVC250/MT

III. Globe, Refractors, Reflectors, Guards
Type
Globe
Globe - Teflon Coated
Globe Guard
Reflector-Dome
Reflector-Angle
Refractor - Type 2
Refractor - Type 5
Large Plastic Refractor Type 2
Large Plastic Refractor Type 3
Large Plastic Refractor Type 5
Refractor Guard
High Bay Reflector/Lens

748

STIBOINFO((CRH:66008com:3L:748))
CH0 3 L - 2 4

Catalog Number
G303
G303-S808
P33
RD739
RA739
GR302
GR305
PGR302
PGR303
PGR305
P23
GRD4

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0749-2 Name: 3L-749

100:
DATE: JAN 19 2006

Time: 5:48:38 PM Operator: JB

50-250W DMV Series

COLOR: CMYK

TCP: 15001

Family Tree

Typedriver Name: TS name csm no.: 100

3L

®

Champ H.I.D. Luminaires

 – available with Lightning Service TM delivery. See Section G for complete details.
* Plastic refractors are for non-hazardous areas only (50-100W Max.)

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:749))
CH0 3 L - 2 4

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

749

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0750-24 Name: 3L-750

DATE: JAN 19 2006

Time: 5:48:40 PM Operator: RB

TCP: 15001

Typedriver Name: TS name csm no.: 100

Temperature Performance Data

50-250W DMV Series

3L

COLOR: CMYK

Champ® H.I.D Luminaires

RATED
AMBIENT
°C

LAMP

Cat. No.
DMVS50
DMVS50
DMVS50
DMVS70
DMVS70
DMVS70
DMVS100
DMVS100
DMVS100
DMVS150
DMVS150
DMVS150
DMVC100
DMVC100
DMVC100
DMVC175
DMVC175
DMVC175
DMVC250
DMVC250
DMVM70
DMVM70
DMVM70
DMVM100
DMVM100
DMVM100
DMVM175
DMVM175
DMVM175
DMVM200
DMVM200
DMVM250
DMVM250
DMVF26
DMVF39
DMVF52
DMVF64
DMVIG85
DMVIG165

Wattage

Globe (G303)
w/ or w/o
Reflector
Refractor
(RA739 or (GR302 or
RD739)*
GR305)

Type

50
HPS
50
HPS
50
HPS
70
HPS
70
HPS
70
HPS
100
HPS
100
HPS
100
HPS
150
HPS
150
HPS
150
HPS
100
MV
100
MV
100
MV
175
MV
175
MV
175
MV
250
MV
250
MV
70
MH
70
MH
70
MH
100
MH
100
MH
100
MH
175
MH
175
MH
175
MH
200
MH
200
MH
250
MH
250
MH
2/13 (26)
CF
3/13 (39)
CF
2/26 (52)
CF
2/32 (64)
CF
85
Induction
165
Induction

40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
40
55
65
40
55
65
40
55
65
40
55
40
55
40
40
40
40
40
40

CLASS II,
DIVISION 1

CLASS I, DIVISION 2

T3A
T3
T3
T3A
T3
T3
T2D
T2C
T2C
T2B
T2B
T2A
T3
T2D
T2C
T2A
T2A
T2A
T1
T1
T3C*
T3B*
T3A*
T3*
T3*
T2D*
T2B*
T2A*
T2A*
T2
T1 (325)
T2
T1 (325)
T3A
T3A
T3
T3
T3
T3

T3A
T3
T3
T3A
T3
T3
T2D
T2C
T2C
T2B
T2B
T2B
T3
T2D
T2C
T2
T2
T2
—
—
T3C
T3C
T3A
T3A
T3A
T2D
T2
T2
T2
—
—
—
—
—
—
—
—
—
—

Group
EFG
EFG
EFG
EFG
EFG
EFG
EFG
EFG
—
EFG
EFG
EFG
EFG
EFG
EFG
EFG
EFG
—
—
—
—
—
—
—
—
—
EFG
EFG
—
—
—
—
—
EFG
EFG
EFG
EFG
—
—

Refractor Globe (G303)
(G302 or
with
G305) or
Reflector
Globe
(RA739 or
(G303)**
RD739)
T6
T5
T4A
T6
T5
T4A
T5
T4A
—
T3C
T4A
—
T4A
T4
T3C
T3B
T4
—
—
—
—
—
—
—
—
—
T3C
T4
—
—
—
—
—
T6
T6
T6
T6
—
T2D

T6
T5
T4A
T6
T5
T4A
T5
T4A
—
T3C
—
—
T4A
T4
T3C
T3C
—
—
—
—
—
—
—
—
—
—
T3C
—
—
—
—
—
—
T6
T6
—
—
—
—

CLASS I, ZONE 2
Simultaneous
Presence
Restricted Globe (G303) Factory
Class I, Div.2
Breathing
with
Sealed
Class II, Div.1
Suffix
Reflector
Suffix
(with G303
S826 w/
(RA739 or S865 AEx
Globe only) Globe (G303)
RD739
nA nR II
T3A
T3
T3
T3A
T3
T3
T3D
T2C
—
T2A
—
—
T2B
T2B
T2B
T2A
—
—
—
—
—
—
—
—
—
—
T2A
—
—
—
—
—
—
—
—
—
—
—
T2D

T6
T5
T5
T6
T5
T5
T6
T5
T4
T5
T4
—
T5
T4
T4
T4
T4
T3
T3
T3
T6
T5
T5
T5
T5
T4
T4
T4
T3
T4
T3
T4
T3
T6
T6
T6
T6
T6
T5

T6
T5
T5
T6
T5
T5
T6
T5
T4
T5
T4
—
T5
T4
T4
T4
T4
T3
T3
T3
T6
T5
T5
T5
T5
T4
T4
T4
T3
T4
T3
T4
T3
T6
T6
T6
T6
T6
—

T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
—
—

Supply
Wire
Suitable
for °C
75
85
90
75
85
90
75
85
90
75
85
85
75
85
90
75
85
90
85
110
60
75
85
60
75
85
85
85
90
75
90
75
90
60
60
60
60
60
75

The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires are listed to UL 844. UL 844 specifies how the
temperatures are measured.
The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring temperatures. Since NEC® 501.1 states that equipment
“...for use in Class I, Zone 0, 1 or 2 locations shall be permitted in Class I, Division 2 locations...” then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They
also have the advantage of meeting the more rigorous mechanical tests of UL 844.
* All DMVM 175W and below MH luminaires provided with Catalog number G303-S808 have a T2A T-code.
** For use with refractor only when this table indicates by means of a T-code that the refractor is suitable for use with Class I, Division 2 luminaires.

750

STIBOINFO((CRH:66008com:3L:750))
CH0 3 L - 2 4

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0751-2 Name: 3L-751

100:
DATE: JAN 19 2006

Time: 5:48:41 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

50-250W DMV Series

3L

®

Champ H.I.D. Luminaires
Dimensions and Weights

DMV Dimensions

Net Luminaire Weights (lbs.)

Pendant Mount

Quad-Mount

25° Angle
Stanchion Mount

Straight Stanchion Mount

Top View

Luminaire with
Luminaire with
Luminaire Lamp
Globe, Guard
Lamp
Globe, Guard
Series
Watts
(lbs.)
Watts
(lbs.)
DMVS
50
23
70
231⁄16
100
241⁄16
150
261⁄8
DMVC
100
211⁄16
175
221⁄4
250
24
DMVM
70
21
100
211⁄16
175
221⁄4
250
24
Add for mounting modules (lbs.):
Pendant
11⁄4
Flexible Pendant
11⁄2
Ceiling
23⁄4
Wall
41⁄2
Quad Mount
31⁄2
Angle Stanchion
31⁄2
Straight Stanchion
41⁄2
Add for reflectors (lbs.):
Dome
11⁄4
30° Angle
13⁄4
Deduct: 1 lb. for luminaire without P33 Guard.
Add: 51⁄2 lbs. for luminaire with GR305 refractor.

Ceiling Mount

Wall Mount

Luminaire with Globe, Guard, Reflectors

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:751))
CH0 3 L - 1 8

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

751

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0752-2 Name: 3L-752

3L

100:
DATE: JAN 19 2006

Time: 5:48:42 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

50-250W DMV Series
Champ® H.I.D. Luminaires

Lamp: 150W/E-23-1/2 clear high pressure sodium (HPS)
Total bare lamp lumens: 16000
To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689.
NOTE: All data provided is for high pressure sodium luminaires with 150W/E-231⁄2 clear lamps. Use
conversion factors (multipliers) shown below for other clear lamp types and wattages. Consult Cooper
Crouse-Hinds for additional photometric data on any Champ series luminaires.

Luminaire with Globe and Dome Reflector
Multipliers: (for use with
candela curves only).

Luminaire Lamp
Series
Watts
DMVS
50
70
100

Isofootcandle Chart: Luminaire with Globe and Dome
Reflector

Conversion
Factor
0.25
0.40
0.59

Luminaire spacing ratio: 1.90

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.759
.643
.551
80
30
.719
.582
.480
10
.683
.530
.424
50
.740
.627
.538
70
30
.703
.570
.471
10
.669
.523
.418
50
.703
.595
.512
50
30
.672
.548
.455
10
.645
.506
.408
50
.669
.567
.488
30
30
.646
.528
.439
10
.622
.492
.399
50
.640
.541
.466
10
30
.619
.508
.424
10
.600
.479
.389
0
0
.582
.459
.370

4
.476
.400
.342
.465
.394
.338
.442
.381
.332
.422
.368
.325
.403
.356
.318
.299

5
.418
.340
.283
.406
.334
.280
.388
.324
.276
.370
.314
.270
.354
.305
.265
.247

% Reflectance
Eff. Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

9
.267
.198
.151
.262
.195
.151
.250
.190
.148
.240
.184
.146
.231
.180
.143
.128

10
.231
.164
.121
.226
.164
.121
.218
.159
.119
.209
.154
.116
.201
.150
.114
.100

752

STIBOINFO((CRH:66008com:3L:752))
CH0 3 L - 1 9

Room Cavity Ratio
6
7
8
.371
.330
.294
.296
.257
.224
.243
.208
.174
.362
.323
.288
.291
.252
.221
.238
.204
.173
.345
.309
.275
.283
.244
.215
.235
.201
.170
.331
.294
.265
.275
.239
.208
.231
.196
.168
.317
.284
.253
.266
.233
.203
.227
.193
.165
.210
.177
.149

US: 1-866-764-5454

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with Globe and 30°
Angle Reflector

Isofootcandle charts show illumination in footcandles on work plane
10 feet below light center. Multiply by factor shown to convert to other
mounting heights.
Height (Ft.)
Factor
Height (Ft.)
Factor
8
1.56
16
.391
12
.694
20
.250
14
.510

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0753-2 Name: 3L-753

100:
DATE: JAN 19 2006

Time: 5:48:43 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

50-250W DMV Series

3L

®

Champ H.I.D. Luminaires

Lamp: 175W/E-28 coated mercury vapor (MV)
Total bare lamp lumens: 8600
To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689.
NOTE: All data provided is for mercury vapor luminaires with 175W/E-28 diffuse lamps. Use conversion
factors (multipliers) shown below for other diffuse lamp types and wattages. Consult Cooper CrouseHinds for additional photometric data on any Champ series luminaire.

Luminaire with Globe and Dome Reflector
Multipliers: (for use with
candela curves only).
Luminaire Lamp
Series
Watts
DMVC
100
250
DMVM

175
250

Isofootcandle Chart: Luminaire with Globe and Dome
Reflector

Conversion
Factor
0.49
1.41
1.63
2.38

Luminaire spacing ratio: 1.7

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.723
.619
.536
80
30
.684
.561
.470
10
.649
.512
.417
50
.705
.604
.524
70
30
.668
.549
.461
10
.635
.505
.412
50
.668
.572
.498
50
30
.638
.528
.445
10
.611
.488
.401
50
.635
.545
.474
30
30
.611
.508
.429
10
.588
.474
.391
50
.606
.519
.453
10
30
.585
.488
.414
10
.566
.460
.381
0
0
.549
.442
.363

4
.467
.396
.342
.456
.390
.338
.434
.377
.331
.414
.365
.324
.395
.352
.317
.299

5
.412
.340
.286
.401
.334
.283
.384
.324
.279
.366
.314
.273
.350
.305
.268
.251

% Reflectance
Eff. Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

9
.269
.204
.160
.263
.201
.159
.252
.196
.157
.243
.190
.154
.233
.186
.151
.138

10
.234
.172
.131
.229
.171
.131
.221
.166
.128
.212
.162
.126
.205
.157
.123
.110

Room Cavity Ratio
6
7
8
.368
.329
.294
.298
.261
.229
.248
.215
.182
.359
.322
.289
.293
.256
.226
.244
.211
.181
.343
.308
.276
.284
.248
.220
.240
.207
.178
.329
.294
.266
.276
.243
.213
.236
.203
.176
.315
.284
.255
.268
.236
.208
.231
.200
.173
.216
.184
.158

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:753))
CH0 3 L - 2 0

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with Globe and 30°
Angle Reflector

Isofootcandle charts show illumination in footcandles on work plane
10 feet below light center. Multiply by factor shown to convert to other
mounting heights.
Height (Ft.)
Factor
Height (Ft.)
Factor
8
1.56
16
.391
12
.694
20
.250
14
.510

Copyright© 2006 Cooper Crouse-Hinds

753

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0754-7 Name: 3L-754

3L

100:
DATE: JAN 19 2006

Time: 5:48:44 PM Operator: RB

200-400W VMV High
Wattage Series
Champ® H.I.D. Luminaires

Application:

Features:
ɀ Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent resistance to
corrosion
ɀ Six mounting arrangements to suit any
lighting layout – pendant, ceiling, wall
bracket, angle stanchion, straight stanchion
and quad-mount.
ɀ Wide range of light sources and wattages
to meet specifiers needs: 200, 250, 400 watt
high pressure sodium (HPS); 250 and 400
watt mercury vapor (MV); 250 and 400 watt
metal halide (MH)
ɀ Hinged ballast housing for ease of
installation and maintenance
ɀ Wide choice of photometric distributions.
Glass globes, glass refractors, and reflector/
lens are available
ɀ All luminaires designed to perform in a
40° C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65°C.
ɀ Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in wet
and corrosive environments.
ɀ Hubs with integral conduit stop and
bushing to help prevent damage to field
wiring during installation
ɀ Low ambient capability to (–40°C)
ɀ Dome and 30° angle reflectors made of
bright white Krydon® material and etched
Alzak® high bay reflectors provide superior
reflectivity
ɀ Grounding wire for safety
ɀ High power factor ballasts (Min. P. F. 90%)
are available in a variety of voltages to meet
local area requirements.
ɀ Mogul base lamp socket

STIBOINFO((CRH:66008com:3L:754))
CH0 3 L - 2 1

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2 &
Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III
& Simultaneous Presence
(with Glass Refractor)
ɀ Marine (with Globe or Glass
Refractor) & Wet Locations
ɀ 3, 3R, 4, 4X; IP66

Standard Materials:

VMV high wattage series Champ luminaires
are used:
ɀ in manufacturing plants, refineries,
chemical, petrochemical, and other industrial
process facilities, waste or sewage treatment
facilities, and other heavy industrial
applications
ɀ in applications involving medium and high
mounting heights
ɀ in applications where energy efficient, high
lumen output is required
ɀ in areas in which ignitible concentrations of
flammable gases or vapors will be present
only due to abnormal, unusual, or accidental
conditions
ɀ in marine applications where water spray
and corrosive atmospheres are
considerations
ɀ in elevated ambient temperatures often
found in industrial applications
ɀ in installations where moisture, dirt, dust,
vibration, corrosion and rough usage are
problems
ɀ wherever the damaging effects of water,
wind, snow, sleet, hot sun, or any
combination of these elements, are problems

754

COLOR: CMYK

ɀ Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%)
ɀ Exterior hardware and guards – stainless
steel
ɀ Reflectors (dome and angle) – Krydon
fiberglass-reinforced polyester material
ɀ Globes – heat and impact resistant
internally fluted glass
ɀ Refractors – glass
ɀ Reflector lens – spun Alzak aluminum,
tempered glass, stainless steel door frame

Standard Finishes:

ɀ Copper-free aluminum – epoxy powder
coat
ɀ Alzak aluminum – natural
ɀ Stainless steel – natural
ɀ Krydon material – high reflectance white

Pendant mount with globe and guard

Certifications and
Compliances:

ɀ NEC and CEC:
- Class I, Division 2, Groups A, B, C, D
- with Glass Refractor - Class II, Class III &
Simultaneous Presence (Class I,
Division 2 and Class II)
- Class 1 Zone 2
ɀ IEC:
- Zone 2 Ex nR IIC
ɀ UL Standards:
- 844, 2279 Hazardous (Classified)
Locations
- 1598 Luminaires
- 1598A Marine Locations
ɀ CSA Standards
- C22.2 No. 137
ɀ IEC Standards
- 60079-15

Ceiling mount with etched Alzak reflector
and tempered glass lens

Options:
The following special options are available
from the factory by adding suffix to luminaire
Cat. No.
Suffix to be
Description
Added to Cat. No.
ɀ Restricted Breathting Construction . . S826‡
- Class I Division 2 & Zone 2
Suitability
Cooler Operating Temperatures
(T-Numbers)
ɀ Certified for IEC Zone 2 . . . . . . . . . S826TB‡
- Furnished with terminal block
crimp terminals and dedicated
voltage ballasts (no MT, DT, or TT)
ɀ Fused – to protect ballast and capacitors
against abnormal line conditions . . . . S658†*
ɀ Quartz auxilliary lighting – comes to full
brightness immediately and remains lit until
the HID lamp attains 60-70% of full
illumination. For non-hazardous locations
only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QTZ
(NOTE: Quartz lamp not included use 100W
single ended lamp – Q100DC, Q100CL/DC, or
100Q/CL/DC). Consult factory for top-hat
limitations.
ɀ Ballast-gard TM starter cutout switch –
prevents starter pulsing when lamp is cycling
or inoperative; prolongs ballast and ignitor
life. Available for use with 200-400W HPS
only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG
ɀ Factory assembled with H.I.D. lamps
installed for additional labor savings. . . . . . FA
ɀ Top hat with stainless steel threaded insert
to attach ballast housing. . . . . . . . . . . . . . S806

US: 1-866-764-5454

CAN: 1-800-265-0502

Ceiling mount with glass refractor

Electrical Ratings:

ɀ 120 to 600 volts and multi-tap刁
ɀ 200, 250, 400W HPS; 250, 400W MV and
MH

Accessories:
ɀ See pages 775 to 776 for complete listing.
刁Alzak is a registered trademark of ALCOA.
† Not for use in Canada.
‡Suffix S826 and S826TB cannot be used with GRD4
Reflector/Lens
* When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0755-3 Name: 3L-755

DATE: JAN 19 2006

Time: 5:48:45 PM Operator: JB

COLOR: CMYK

ɀ

200-400W High
Pressure Sodium

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2 &
Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

VMV High Wattage Series
Champ® H.I.D. Luminaires

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III
& Simultaneous Presence
(with Glass Refractor)
ɀ Marine (with Globe or Glass
Refractor) & Wet Locations
ɀ 3, 3R, 4, 4X; IP56 to IP66

3L

See notes 1 (to specify voltage) and 2. For guards and other optics see VMV Luminaires - Ordering by Components section.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount
(Rigid or Flexible)

Hub
Size
3⁄4
1
3⁄4
1
3⁄4
1

Lamp
Watts
200
250
400

With G303 Globe
and P33 Guard
VMVS2A200GP
VMVS3A200GP
VMVS2A250GP
VMVS3A250GP
VMVS2A400GP
VMVS3A400GP

With GR305 Glass
Refractor
VMVS2A200GR305
VMVS3A200GR305
VMVS2A250GR305
VMVS3A250GR305
VMVS2A400GR305
VMVS3A400GR305

With GRD4
Reflector/Lens2
VMVS2A200GRD4
VMVS3A200GRD4
VMVS2A250GRD4
VMVS3A250GRD4
VMVS2A400GRD4
VMVS3A400GRD4

VMVS2C200GP
VMVS3C200GP
VMVS2C250GP
VMVS3C250GP
VMVS2C400GP
VMVS3C400GP

VMVS2C200GR305
VMVS3C200GR305
VMVS2C250GR305
VMVS3C250GR305
VMVS2C400GR305
VMVS3C400GR305

VMVS2C200GRD4
VMVS3C200GRD4
VMVS2C250GRD4
VMVS3C250GRD4
VMVS2C400GRD4
VMVS3C400GRD4

VMVS2TW200GP
VMVS3TW200GP
VMVS2TW250GP
VMVS3TW250GP
VMVS2TW400GP
VMVS3TW400GP

VMVS2TW200GR305
VMVS3TW200GR305
VMVS2TW250GR305
VMVS3TW250GR305
VMVS2TW400GR305
VMVS3TW400GR305

3⁄4
1
3⁄4
1
3⁄4
1

200

3⁄4
1
3⁄4
1
3⁄4
1

200

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
121⁄2° Angle

3⁄4
3⁄4

200
250
400

VMVS25Q200GP
VMVS25Q250GP
VMVS25Q400GP

VMVS25Q200GR305
VMVS25Q250GR305
VMVS25Q400GR305

VMVS25Q200GRD4
VMVS25Q250GRD4
VMVS25Q400GRD4

Stanchion Mount
25° Angle

11⁄2
11⁄2
11⁄2

200
250
400

VMVSJ200GP
VMVSJ250GP
VMVSJ400GP

VMVSJ200GR305
VMVSJ250GR305
VMVSJ400GR305

VMVSJ200GRD4
VMVSJ250GRD4
VMVSJ400GRD4

Stanchion Mount
Straight

11⁄2
11⁄2
11⁄2

200
250
400

VMVSP200GP
VMVSP250GP
VMVSP400GP

VMVSP200GR305
VMVSP250GR305
VMVSP400GR305

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

250
400

250
400

3⁄4

1.
Voltage
Suffix

Multi Tap
/MT

Standard Voltage Ballasts - 60Hz
NEC/UL
120V
480V
/120
/480

CEC/CSA (cUL)
Tri Tap
/TT

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
208V CWI
240V CWI
480V CWI
600V CWI
220V 60Hz
Suffix
/208CWI
/240CWI
/480CWI
/600CWI
/220
2. Options - Add the Required Options Suffixes from page 754, In Alpha-numeric Order.
TM
 – available with Lightning Service delivery. See Section G for details

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:755))
CH0 3 L - 2 2

CAN: 1-800-265-0502

120V
/120

EXPORT
220V 50Hz
/220 50

Copyright© 2006 Cooper Crouse-Hinds

230V 50Hz
/230 50

240V 50Hz
/240 50

755

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0756-3 Name: 3L-756

3L

DATE: JAN 19 2006

Time: 5:48:47 PM Operator: JB

250-400W Pulse Start
Metal Halide
VMV High Wattage Series
Champ® H.I.D. Luminaires

COLOR: CMYK

ɀ

TCP: 15001

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2 &
Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III
& Simultaneous Presence
(with Glass Refractor)
ɀ Marine (with Globe or Glass
Refractor) & Wet Locations
ɀ 3, 3R, 4, 4X; IP56 to IP66

See Note 1 (to specify voltage) and 2. For guards and other optics, see VMV luminaires - ordering by components section
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount
(Rigid or Flexible)

Hub
Size
3⁄4
1
3⁄4
1
3⁄4
1

Lamp With G303 Globe
Watts and P33 Guard
250
VMVM2A250GP-S828
VMVM3A250GP-S828
320

With GR305 Glass
Refractor
VMVM2A250GR305-S828
VMVM3A250GR305-S828
VMVM2A320GR305-S828
VMVM3A320GR305-S828
VMVM2A400GR305-S828
VMVM3A400GR305-S828

With GRD4
Reflector/Lens
VMVM2A250GRD4-S828
VMVM3A250GRD4-S828
VMVM2A320GRD4-S828
VMVM3A320GRD4-S828
VMVM2A400GRD4-S828
VMVM3A400GRD4-S828

VMVM2C250GP-S828
VMVM3C250GP-S828

VMVM2C250GR305-S828
VMVM3C250GR305-S828
VMVM2C320GR305-S828
VMVM3C320GR305-S828
VMVM2C400GR305-S828
VMVM3C400GR305-S828

VMVM2C250GRD4-S828
VMVM3C250GRD4-S828
VMVM2C320GRD4-S828
VMVM3C320GRD4-S828
VMVM2C400GRD4-S828
VMVM3C400GRD4-S828

VMVM2C250GP-S828
VMVM3C250GP-S828

VMVM2TW250GR305-S828
VMVM3TW250GR305-S828
VMVM2TW320GR305-S828
VMVM3TW320GR305-S828
VMVM2TW400GR305-S828
VMVM3TW400GR305-S828

VMVM2TW250GRD4-S828
VMVM3TW250GRD4-S828
VMVM2TW320GRD4-S828
VMVM3TW320GRD4-S828
VMVM2TW400GRD4-S828
VMVM3TW400GRD4-S828

400

3⁄4
1
3⁄4
1
3⁄4
1

250

3⁄4
1
3⁄4
1
3⁄4
1

250

Quad-Mount
Pendant,
Adjustable ThruFeed, 25° Angle,
121⁄2° Angle

3⁄4
3⁄4

250
320
400

VMVM25Q250GP-S828 VMVM25Q250GR305-S828
VMVM25Q320GR305-S828
VMVM25Q400GR305-S828

VMVM25Q250GRD4-S828
VMVM25Q320GRD4-S828
VMVM25Q400GRD4-S828

Stanchion Mount
25° Angle

11⁄2
11⁄2
11⁄2

250
320
400

VMVMJ250GP-S828

VMVMJ250GR305-S828
VMVMJ320GR305-S828
VMVMJ400GR305-S828

VMVMJ250GRD4-S828
VMVMJ320GRD4-S828
VMVMJ400GRD4-S828

Stanchion Mount
Straight

11⁄2
11⁄2
11⁄2

250
320
400

VMVMP250GP-S828

VMVMP250GR305-S828
VMVMP320GR305-S828
VMVMP400GR305-S828

VMVMP250GRD4-S828
VMVMP320GRD4-S828
VMVMP400GRD4-S828

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

3⁄4

320
400

320
400

1.
Voltage
Suffix

Multi Tap
/MT

Standard Voltage Ballasts - 60Hz
NEC/UL
120V
480V
/120
/480

CEC/CSA (cUL)
Tri Tap
/TT

120V
/120

Optional Voltage Ballasts - 50 or 60Hz
EXPORT

2.

756

STIBOINFO((CRH:66008com:3L:756))
CH0 3 L - 2 4

Voltage
220V 60Hz
220V 50Hz
230V 50Hz
Suffix
/220
/220 50
/230 50
Options - Add the Required Options Suffixes from page 754, In Alpha-numeric Order.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

240V 50Hz
/240 50

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0757-2 Name: 3L-757

DATE: JAN 19 2006

Time: 5:48:49 PM Operator: RB

COLOR: CMYK

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2 &
Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)

250-400W Metal
Halide

ɀ

VMV High Wattage Series
Champ® H.I.D. Luminaires

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III
& Simultaneous Presence
(with Glass Refractor)
ɀ Marine (with Globe or Glass
Refractor) & Wet Locations
ɀ 3, 3R, 4, 4X; IP56 to IP66

3L

See Note 1 (to specify voltage) and 2. For guards and other optics, see VMV luminaires - ordering by components section
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount
(Rigid or Flexible)

Hub
Size
3⁄4
1
3⁄4
1

Lamp
Watts
250
400

With G303 Globe
and P33 Guard
VMVM2A250GP
VMVM3A250GP
N/A
N/A

With GR305 Glass
Refractor
VMVM2A250GR305
VMVM3A250GR305
VMVM2A400GR305
VMVM3A400GR305

With GRD4
Reflector/Lens
VMVM2A250GRD4
VMVM3A250GRD4
VMVM2A400GRD4
VMVM3A400GRD4

VMVM2C250GP
VMVM3C250GP
N/A
N/A

VMVM2C250GR305
VMVM3C250GR305
VMVM2C400GR305
VMVM3C400GR305

VMVM2C250GRD4
VMVM3C250GRD4
VMVM2C400GRD4
VMVM3C400GRD4

VMVM2TW250GP
VMVM3TW250GP
N/A
N/A

VMVM2TW250GR305
VMVM3TW250GR305
VMVM2TW400GR305
VMVM3TW400GR305

3⁄4
1
3⁄4
1

250

3⁄4
1
3⁄4
1

250

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25°
Angle, 121⁄2° Angle

3⁄4
3⁄4

250
400

VMVM25Q250GP
N/A

VMVM25Q250GR305
VMVM25Q400GR305

VMVM25Q250GRD4
VMVM25Q400GRD4

Stanchion Mount
25° Angle

11⁄2
11⁄2

250
400

VMVMJ250GP
N/A

VMVMJ250GR305
VMVMJ400GR305

VMVMJ250GRD4
VMVMJ400GRD4

Stanchion Mount
Straight

11⁄2
11⁄2

250
400

VMVMP250GP
N/A

VMVMP250GR305
VMVMP400GR305

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

400

400

1.
Voltage
Suffix

Multi Tap
/MT

Standard Voltage Ballasts - 60Hz
NEC/UL
120V
480V
/120
/480

CEC/CSA (cUL)
Tri Tap
/TT

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts

2.

Voltage
208V CWI
240V CWI
600V CWI
220V 60Hz
Suffix
/208CWI
/240CWI
/600CWI
/220
Options - Add the Required Options Suffixes from page 754, In Alpha-numeric Order.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:757))
CH0 3 L - 2 4

CAN: 1-800-265-0502

120V
/120

EXPORT
220V 50Hz
/220 50

Copyright© 2006 Cooper Crouse-Hinds

230V 50Hz
/230 50

240V 50Hz
/240 50

757

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0758-3 Name: 3L-758

3L

DATE: JAN 19 2006

Time: 5:48:50 PM Operator: JB

COLOR: CMYK

ɀ

TCP: 15001

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2 &
Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)

250-400W Mercury
Vapor

ɀ

VMV High Wattage Series
Champ® H.I.D. Luminaires

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III
& Simultaneous Presence
(with Glass Refractor)
ɀ Marine (with Globe or Glass
Refractor) & Wet Locations
ɀ 3, 3R, 4, 4X; IP66

See Note 1 (to specify voltage) and 2. For guards and other optics see VMV - Luminaires - Ordering by Components section.
Mounting
Style
Pendant Mount
(Rigid or Flexible)

Hub
Size
3⁄4
1
3⁄4
1

Lamp
Watts
250

BASIC CATALOG NUMBER
With GR305 Glass
Refractor
VMVC2A250GR305
VMVC3A250GR305
VMVC2A400GR305
VMVC3A400GR305

With GRD4
Reflector/Lens2
VMVC2A250GRD4
VMVC3A250GRD4
VMVC2A400GRD4
VMVC3A400GRD4

VMVC2C250GP
VMVC3C250GP
N/A
N/A

VMVC2C250GR305
VMVC3C250GR305
VMVC2C400GR305
VMVC3C400GR305

VMVC2C250GRD4
VMVC3C250GRD4
VMVC2C400GRD4
VMVC3C400GRD4

VMVC2TW250GP
VMVC3TW250GP
N/A
N/A

VMVC2TW250GR305
VMVC3TW250GR305
VMVC2TW400GR305
VMVC3TW400GR305

VMVC25Q250GP
N/A
N/A

VMVC25Q250GR305

VMVC25Q250GRD4

VMVC25Q400GR305

VMVC25Q400GRD4

VMVCJ250GRD4
VMVCJ400GRD4

With G303 Globe
and P33 Guard
VMVC2A250GP
VMVC3A250GP
N/A
N/A

400

3⁄4
1
3⁄4
1

250

3⁄4
1
3⁄4
1

250

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25°
Angle, 121⁄2° Angle

3⁄4

250
400

Stanchion Mount
25° Angle

11⁄2
11⁄2

250
400

VMVCJ250GP
N/A

VMVCJ250GR305
VMVCJ400GR305

Stanchion Mount
Straight

11⁄2
11⁄2

250
400

VMVCP250GP
N/A

VMVCP250GR305
VMVCP400GR305

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

400

400

3⁄4

1.
Voltage
Suffix

Multi Tap
/MT

Standard Voltage Ballasts - 60Hz
NEC/UL
120V
480V
/120
/480

CEC/CSA (cUL)
Tri Tap
/TT

120V
/120

Optional Voltage Ballasts - 50 or 60Hz
EXPORT
Voltage
Suffix
2.

758

STIBOINFO((CRH:66008com:3L:758))
CH0 3 L - 2 3

220V 60Hz
/220

220V 50Hz
/220 50

230V 50Hz
/230 50

Options - Add the required options suffixes from page 754, in Alpha-numeric order.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

240V 50Hz
/240 50

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0759-1 Name: 3L-759

100:
DATE: JAN 19 2006

Time: 5:48:51 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

VMV High Voltage Luminaires Ordering by Components

3L

VMV High Wattage Luminaires are available in components
A complete luminaire consists of:
I.
Champ Cover (mounting module)
II.
VMV Ballast Housing - Include voltage and required option(s)
III.
Optical & Guard Components - Globe, Reflector, Refractor, Guard

I. Champ Cover (Mounting Module):
Type
Pendant
Ceiling
Wall
Stanchion - 25 Degree Angle
Stanchion - Straight
Quad-Mount

Conduit
3⁄4

1
3⁄4
1
3⁄4
1
11⁄2
11⁄2
3⁄4

Cat. No.
APM2
APM3
CM2
CM3
TWM2
TWM3
JM5
PM5
QM25

II. Ballast Housings. Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Type
High Pressure Sodium

Metal Halide

Mercury Vapor

Lamp
Watts

Catalog Number

200
250
400
70
250
400
250
400

VMVS200/MT
VMVS250/MT
VMVS400/MT
LMVM070/MT
VMVM250/MT
VMVM400/MT
VMVC250/MT
VMVC400/MT

III. Globe, Refractors, Reflectors, Guards
Type
Globe
Globe Guard
Reflector-Dome
Reflector-Angle
Refractor - Type 2
Refractor - Type 5
Refractor Guard
High Bay Reflector/Lens

Catalog Number
G303
P33
RD739
RA739
GR302
GR305
P23
GRD4

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:759))
CH0 3 L - 3 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

759

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0760-1 Name: 3L-760

3L

100:
DATE: JAN 19 2006

Time: 5:48:52 PM Operator: JB

200-400 VMV High Wattage Series

COLOR: CMYK

TCP: 15001

Family Tree

Champ® H.I.D. Luminaires

 – available with Lightning Service TM delivery. See Section G for complete details.

760

STIBOINFO((CRH:66008com:3L:760))
CH0 3 L - 3 6

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0761-1 Name: 3L-761

DATE: JAN 19 2006

Time: 5:48:53 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Temperature Performance Data

200-400W VMV
High Wattage Series

3L

Champ® H.I.D. Luminaires

Lamp
Watts

Ambient
Temp C

Optics

Class I
(Gas/Vapors)

Class II
(Dust)
and
Class III

Non
Restricted
Breathing

Restricted
Breathing

Standard
Product

Option
S826(TB)

Division 2

Zone 2 or
Division 2

Simultaneous
Presence
Gas and Dust Present in
the Same Area
Non
Restricted
Breathing

Restricted
Breathing

Standard
Product

Standard
Product

Option
S826

Standard
Product

Class I,
Division 2
and
Class II

Class I, Zone 2
or Division 2
and
Class II

Ex nR

Supply
Wire
Temp
C

Ex nR

G303

X

–

X

–

–

–

–

GR305

–

X

–

X

X

X

X

GRD4

X

–

–

–

–

–

–

325 C
325 C
325 C
350 C
350 C
350 C
350 C
T1

325 C
325 C
325 C
350 C
350 C
350 C
350 C
T1

T3
T3
T3
T3
T3
T3
T3
T3

T4
T4
–
T4
T4
–
T4
T4

T3C
–
–
T3C
–
–
T3C
–

T1/T3C
–
–
T1/T3C
–
–
T1/T3C
–

T3C
–
–
T3C
–
–
T3C
–

75
75
85
75
85
–
85
90

40
55
40
55

350 C
350 C
350 C
350 C

325 C
350 C
325 C
350 C

T3
T4
T3
T3

T4
T3
T4
T3

T3B
–
T3B
–

350 C/T3B
–
350 C/T3B
–

T3B
–
T3B
–

85
90
85
90

40
55
40
55

–
–
–
–

325 C
–
325 C
–

T1
–
T1
–

T4
–
T4
–

T3B
–
T3B
–

350 C/T3B
–
350 C/T3B
–

T3B
–
T3B
–

85
–
85
–

350 C
T1
–
–

325 C
350 C
325 C
–

T3
T3
T1
–

T4
T3
T4
–

T3B
–
T3B
–

350 C/T3B
–
350 C/T3B
–

T3B
–
T3B
–

85
90
85
–

High Pressure Sodium
200

250

400

40
55
65
40
55
65
40
55

Metal Halide
200
(S828)

250
(Includes
S828)

320
(S828)

400
(includes
S828)

Mercury Vapor
250
400

40
55
40
55

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:761))
CH0 3 L - 3 6

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

761

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0762-1 Name: 3L-762

3L

100:
DATE: JAN 19 2006

Time: 5:48:54 PM Operator: JB

200-400W VMV High Wattage Series

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Dimensions and Weights

Champ® H.I.D. Luminaires

Pendant
Mount

Ceiling Mount

Wall
Mount

25° Angle
Stanchion Mount

QuadMount

Straight Stanchion Mount
Luminaire with Etched Alzak
Reflector/Lens
Luminaire with
Globe,
Guard,
Reflectors

Net Luminaire Weights (lbs.):
Luminaire with:
Lamp
Globe,
Reflector/
Watts
Guard
Lens
200
291⁄2
30
250
291⁄2
30
400
381⁄2
39
VMVC
250
291⁄2
30
400
33
VMVM
250
321⁄2
33
400
34
Add for mounting modules (lbs):
Quad-Mount
Pendant
11⁄4
Ceiling
23⁄4
Angle Stanchion
Wall
41⁄2
Straight Stanchion
Add for reflectors (lbs):
30° Angle
Dome
11⁄2
High Bay
13⁄4
Deduct: 11⁄2 lb. for Luminaire without P33 Guard

Luminaire
Series
VMVS

762

STIBOINFO((CRH:66008com:3L:762))
CH0 3 L - 2 5

US: 1-866-764-5454

Glass
Refractor
321⁄2
321⁄2
411⁄2
351⁄2
351⁄2
353⁄4
351⁄2
31⁄2
31⁄2
41⁄2
11⁄2

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Luminaire with
Glass Refractor, Guard

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0763-2 Name: 3L-763

DATE: JAN 19 2006

Time: 5:49:57 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

200-400W VMV High
Wattage Series

3L

Champ® H.I.D. Luminaires

Lamp: 250W/E-18 high pressure sodium (HPS)
Total bare lamp lumens: 27500
To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to
689. NOTE: All data provided is for high pressure sodium luminaires with 250W/E-18 clear lamps.
Use conversion factors (multipliers) shown below for other clear lamp types and wattages.
Consult Cooper Crouse-Hinds for additional photometric data on any Champ series luminaire.

Luminaire with Globe and Dome Reflector

Temperature Performance Data with Globe & Guard

Multipliers (for use with
candela curves only)
Luminaire
Series
VMVS

Lamp
Watts
200
400

Convversion
Factors
0.80
1.82

Lamp
Ambient
Watts
Temp °C
High Pressure Sodium:
200
40
55
65
250
40
55
65
400

Luminaire spacing ratio: 2.0

Mercury Vapor:
250

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil. Wall

Room Cavity Ratio
1
2
3

50
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0
% Reflectance
Eff. Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

.750
.640
.550
.711
.582
.482
.677
.532
.429
.732
.625
.538
.696
.570
.474
.664
.526
.424
.695
.594
.513
.666
.549
.458
.641
.509
.414
.663
.567
.490
.640
.530
.443
.618
.496
.405
.635
.542
.469
.615
.510
.429
.597
.483
.395
.580
.464
.377
Room Cavity Ratio
6
7
8
.369
.327
.290
.295
.255
.222
.243
.208
.173
.360
.320
.285
.291
.251
.219
.239
.204
.172
.344
.306
.272
.283
.243
.213
.236
.200
.170
.330
.292
.262
.275
.238
.207
.233
.196
.167
.317
.282
.251
.267
.233
.202
.229
.194
.165
.212
.178
.149

80

400
4

5

.476
.402
.346
.465
.397
.343
.443
.384
.336
.423
.372
.330
.405
.360
.323
.305

.416
.341
.285
.405
.335
.282
.388
.326
.279
.371
.316
.273
.355
.307
.268
.251

9
.263
.196
.150
.258
.193
.149
.247
.189
.147
.238
.183
.145
.229
.179
.142
.128

10
.229
.163
.121
.224
.163
.121
.216
.159
.119
.207
.154
.116
.200
.150
.114
.101

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:763))
CH0 3 L - 2 6

CAN: 1-800-265-0502

Class I Division 2
Globe & Guard

Supply
Wire °C

325°C
325°C
325°C
350°C
350°C
350°C

75
75
85
75
85
—

40
55
65

T1
T1
—

85
90
—

40
55
65
40
55
65

350°C
T1
—
—
—
—

85
85
—
85
—
—

350°C
350°C
—
—
—
—

75
90
90
75
—
—

Metal Halide:
250

40
55
65
400
40
55
65
(Data not applicable with QTZ suffix)

Temperature Data With GR305 or GR302 Refractor
Simultaneous
Presence
Ambient Class I
Class II
Class I, Div. 2/
Wattage Temp °C Division 2 Division 1 Class II, Div. 1
High Pressure Sodium
200
40
350°C
T3C
T1/T3C
55
T1
–
–
250
40
350°C
T3C
T1/T3C
55
T1
–
–
400
40
350°C
T3C
T1/T3C
55
T1
–
–

75
75
75
85
85
90

Mercury Vapor
250
40
55
400
40

325°C
350°C
325°C

T3B
–
T3B

350°C/T3B
–
350°C/T3B

85
85
85

Metal Halide
250
40
55
400
40

325°C
350°C
325°C

T3B
–
T3B

350°C/T3B
–
350°C/T3B

85
90
85

Copyright© 2006 Cooper Crouse-Hinds

Supply
Wire °C

763

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0764-2 Name: 3L-764

3L

100:
DATE: JAN 19 2006

Time: 5:49:58 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

200-400W VMV High
Wattage Series
Champ® H.I.D. Luminaires

Lamp: 250W/E-28 coated (DX) mercury vapor (MV)
Total bare lamp lumens: 13000
To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689.
NOTE: All data provided is for mercury vapor luminaires, with 250W/E-28 diffuse lamps. Use
conversion factors (multipliers) shown below for other diffuse lamp types and wattages. Consult
Cooper Crouse-Hinds for additional photometric data on any Champ series luminaire.

Luminaire with Etched Alzak® Reflector and
Tempered Glass Lens

Luminaire with I.E.S. Type V Glass
Refractor
Multipliers: (for use with
candela curves only).

Luminaire
Series
VMVC
VMVM

Lamp
Watts
400
250
400

Multipliers: (for use with
candela curves only).

Conversion
Factor
1.73
1.58
2.77

Luminaire
Series
VMVC
VMVM

Conversion
Factor
1.73
1.58
2.77

Luminaire spacing ratio: 1.60

Luminaire spacing ratio: 1.30

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.711
.585
.508
80
30
.659
.524
.430
10
.614
.464
.368
50
.677
.566
.484
70
30
.630
.500
.411
10
.586
.446
.353
50
.611
.509
.435
50
30
.573
.456
.375
10
.538
.409
.326
50
.551
.457
.390
30
30
.521
.414
.341
10
.482
.375
.299
50
.496
.409
.349
10
30
.471
.374
.308
10
.449
.343
.273
0
0
.419
.314
.246

4
.440
.358
.295
.418
.343
.285
.376
.313
.263
.337
.285
.242
.301
.257
.220
.195

5
.384
.304
.244
.365
.291
.234
.330
.266
.217
.296
.242
.200
.265
.219
.182
.159

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.681
.609
.544
80
30
.658
.573
.500
10
.638
.542
.465
50
.667
.598
.536
70
30
.646
.564
.494
10
.627
.537
.461
50
.639
.576
.518
50
30
.622
.548
.482
10
.607
.523
.453
50
.615
.556
.501
30
30
.602
.533
.471
10
.589
.512
.446
50
.594
.537
.486
10
30
.582
.518
.460
10
.571
.501
.438
0
0
.559
.489
.426

4
.483
.433
.394
.476
.429
.391
.459
.419
.387
.445
.410
.382
.432
.401
.377
.364

5
.430
.376
.337
.422
.372
.335
.410
.366
.332
.397
.358
.328
.386
.352
.324
.312

% Reflectance
Eff. Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

9
.251
.181
.134
.240
.174
.129
.218
.160
.120
.197
.146
.110
.178
.133
.101
.084

10
.223
.156
.113
.213
.151
.109
.195
.139
.101
.177
.127
.092
.160
.115
.083
.068

% Reflectance
Eff. Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

9
.273
.220
.183
.269
.218
.183
.261
.214
.182
.254
.210
.180
.247
.208
.179
.168

10
.234
.182
.148
.230
.182
.148
.225
.178
.147
.218
.175
.145
.213
.173
.144
.133

Room Cavity Ratio
6
7
8
.343
.306
.274
.285
.231
.203
.209
.180
.152
.326
.292
.262
.253
.220
.195
.199
.171
.147
.294
.264
.237
.232
.201
.179
.185
.158
.136
.265
.237
.215
.212
.185
.162
.171
.145
.125
.238
.215
.193
.191
.168
.148
.155
.133
.114
.135
.113
.096

Room Cavity Ratio
6
7
8
.383
.340
.302
.329
.286
.249
.291
.250
.212
.377
.335
.298
.326
.283
.248
.288
.247
.211
.365
.325
.289
.320
.277
.243
.286
.245
.209
.356
.315
.282
.315
.274
.238
.284
.242
.208
.346
.308
.274
.309
.270
.235
.281
.240
.206
.269
.228
.194

Alzak is a registered trademark of Alcoa.

764

STIBOINFO((CRH:66008com:3L:764))
CH0 3 L - 2 7

Lamp
Watts
400
250
400

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0765-3 Name: 3L-765

100:
DATE: JAN 19 2006

Time: 5:49:59 PM Operator: RB

ɀ

50-175W N2MV
Series

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2 &
Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

Champ® H.I.D. Luminaires
Non-Metallic

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups F, G, Cl. III
& Simultaneous Presence
(100W max)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP56

3L

Options:
Application:
N2MV series Champ luminaires are used:
ɀ in areas in which ignitable concentrations of
flammable gases or vapors will be present
due to abnormal, unusual or accidental
conditions.
ɀ in installations where moisture, dirt,
vibration, corrosion or rough usage are
concerns.
ɀ wherever the damaging effects of water,
wind, snow, sleet, hot sun or any
combination of these elements are found.
ɀ ideal for marine use; resists the harmful
effects of salt water.
ɀ withstands the harshest of corrosive
environments.
ɀ to provide low wattage spot and
floodlighting.
ɀ for general area lighting.
ɀ in areas where the ambient temperature will
get as low as 40°C (–40°F).
ɀ In manufacturing plants, refineries,
chemical, petrochemical and other industrial
process facilities, wastewater and sewage
treatment facilities, offshore, dockside and
harbor installations as well as other heavy
industrial applications.

Features:
ɀ Housing and mounting modules made of
polyphenylene sulfide (PPS) for strength and
maximum resistance to corrosion.
ɀ Pendant mounting module equipped with
integral hub set screws for vibration
resistance.
ɀ Hubs are provided with an integral bushing
to help prevent damage to field wiring during
installation and ground connection for
positive bonding.
ɀ Guard, hub inserts, stanchion elbow and
hardware made of stainless steel for
maximum resistance to corrosion.
ɀ Grounding wire for safety.
ɀ Stainless steel open bottom guard permits
direct access to the globe for easy relamping.
ɀ Hinged assembly allows the luminaire to
hang free during installation to permit the use
of both hands when wiring.
ɀ One, external captive screw for ease of
installation.
ɀ Handle – hinge assembly doubles as a
handle for ease of installation, especially
when carrying up a ladder.

The following special options are available
from the factory by adding suffix to luminaire
Cat. No.:
Suffix to be
Description
Added to Cat. No.

Standard Materials:
ɀ Housing, mounting modules, component
pallets – polyphenylene sulfide PPS
ɀ Guard, hub inserts, stanchion elbow,
hardware – stainless steel
ɀ Globe – heat tempered
ɀ Gaskets – silicone rubber

Electrical Ratings:
ɀ 120, multi-tap/MT刁 (120, 208, 240 and 277),
Dual-Tap/DT (120, 277 volts), Tri-Tap/TT (120,
277, 347 volts) 480 volt, 600 volt, 220/240
volt-50 Hz
ɀ 50-150W HPS; 100-175W MV; 70-175W MH

Certifications and
Compliances:
ɀ NEC and CEC:
– Class I, Division 2, Groups A, B, C, D
– 100W Maximum - Class II, Class III &
Simultaneous Presence (Class I,
Division 2 and Class II)
– Class 1 Zone 2
ɀ IEC:
- Zone 2 Ex nR IIC
ɀ UL Standards:
- 844, 2279 Hazardous (Classified)
Locations
- 1598 Luminaires
- 1598A Marine Locations
ɀ CSA Standards
- C22.2 No. 137
ɀ IEC Standards
- 60079-15

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:765))
CH0 3 L - 2 8

ɀ Restricted Breathing Construction. . . . S826
- Class I Division 2 & Zone 2
Suitability
Cooler Operating Temperatures
(T-Numbers)
ɀ Certified for IEC Zone 2 . . . . . . . . . . S826TB
- Furnished with terminal block
crimp terminals and dedicated
voltage ballasts (no MT, DT, or TT)
ɀ Wall Mount Arm. For converting a ceilingmount luminaire to a wall-mount. N2MV-WM1
ɀ Ballast Gard TM starter cut-out switch.
Prevents starter pulsing when lamp is cycling
or inoperative; prolongs ballast and ignitor
life. Available for use with 50-150 watt – HPS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG
ɀ Factory Assembled. For a factory
assembled luminaire with lamp installed . . FA
ɀ Instant Restrike. Enables a hot HPS lamp to
immediately restrike after a momentary loss
of arc due to voltage fluctuation or power
outage. It has no effect on the warm-up
period of cold lamps. Available for use with
50-150W LX HPS only. . . . . . . . . . . . . . . . . . . IR
ɀ Quartz Auxiliary Lighting. Comes to full
brightness immediately and remains lit until
the HID lamp attains 60–70% of full
illumination. For non-hazardous locations
only. (Note: QTZ lamp not included; use
100W single ended lamp – Q100DC, Q100CL/
DC, or 100Q/CL/DC) Consult factory for
top-hat limitations . . . . . . . . . . . . . . . . . . . . QTZ
ɀ Fused. To protect ballast and capacitor
against abnormal line conditions . . . . . . S658
(Not for use in Canada)
ɀ Furnished with Lamps. . . . . . . . . . . . . . . S714
ɀ Teflon® Coated Globe. For additional
protection against breakage. For use with
50–100W HPS, 70–175W MH and 100–175W
MV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S808

Accessories:
ɀ See pages 775 and 776 for complete
listing.

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

765

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0766-4 Name: 3L-766

3L

DATE: JAN 19 2006

Time: 5:50:00 PM Operator: RB

COLOR: CMYK

ɀ

50-150W High
Pressure Sodium

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2 &
Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

N2MV Series
Champ® H.I.D. Luminaires

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups F, G, Cl. III
& Simultaneous Presence
(100W max)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP56

See notes 1 (to specify voltage) 2 and 3. For guards and other optics see N2MV Luminaires - Ordering by Components Section.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Ceiling Mount
Thru-Feed

Stanchion Mount
25° Angle

Hub
Size
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
11⁄2
11⁄2
11⁄2
11⁄2

Lamp
Watts
50
70
100
150
50
70
100
150
50
70
100
150

With G303 Globe and
P33 Guard
N2MVS2A050GP
N2MVS3A050GP
N2MVS2A070GP
N2MVS3A070GP
N2MVS2A100GP
N2MVS3A100GP
N2MVS2A150GP
N2MVS3A150GP
N2MVS2C050GP
N2MVS3C050GP
N2MVS2C070GP
N2MVS3C070GP
N2MVS2C100GP
N2MVS3C100GP
N2MVS2C150GP
N2MVS3C150GP
N2MVSJ050GP
N2MVSJ070GP
N2MVSJ100GP
N2MVSJ150GP

With GR305
Glass Refractor
N2MVS2A050GR305
N2MVS3A050GR305
N2MVS2A070GR305
N2MVS3A070GR305
N2MVS2A100GR305
N2MVS3A100GR305
N2MVS2A150GR305
N2MVS3A150GR305
N2MVS2C050GR305
N2MVS3C050GR305
N2MVS2C070GR305
N2MVS3C070GR305
N2MVS2C100GR305
N2MVS3C100GR305
N2MVS2C150GR305
N2MVS3C150GR305
N2MVSJ050GR305
N2MVSJ070GR305
N2MVSJ100GR305
N2MVSJ150GR305
Standard Voltage Ballasts - 60Hz

1.
Voltage
Suffix

Multi Tap
/MT

NEC/UL
Dual Tap
/DT

120V
/120

480V
/480

Tri Tap
/TT

CEC/CSA (cUL)
Dual Tap
120V
/DT
/120

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

600V CWI
/600CWI

EXPORT
220V 60Hz
/220

220V 50Hz
/220 50

2. 150W HPS Luminaires, 55V Lamps is standard, for 100V lamps - Add suffix ‘‘CE’’. 50W HPS luminaire is dual-tap only.
3. Options - Add the required options suffixes from page 765, In Alpha-numeric order.

766

STIBOINFO((CRH:66008com:3L:766))
CH0 3 L - 2 9

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

230V 50Hz
/230 50

240V 50Hz
/240 50

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0767-8 Name: 3L-767

DATE: JAN 19 2006

150-175W Pulse Start
Metal Halide
N2MV Series
Champ® H.I.D. Luminaires

Time: 5:50:01 PM Operator: RB

ɀ

COLOR: CMYK

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2 &
Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups F, G, Cl. III
& Simultaneous Presence
(100W max)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP56

3L

See notes 1 (to specify voltage) and 2. For guards and other optics see N2MV Luminaires - Ordering by Components Section.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Ceiling Mount
Thru-Feed

Stanchion Mount
25° Angle

Hub
Size
3⁄4
1
3⁄4
1

Lamp
Watts
150
175

3⁄4

150

1
3⁄4
1

175

11⁄2
11⁄2

150
175

With G303 Globe and
P33 Guard
N2MVM2A150GP-S828
N2MVM3A150GP-S828
N2MVM2A175GP-S828
N2MVM3A175GP-S828

With GR305-S828
Glass Refractor
N2MVM2A150GR305-S828
N2MVM3A150GR305-S828
N2MVM2A175GR305-S828
N2MVM3A175GR305-S828

N2MVM2C150GP-S828
N2MVM3C150GP-S828
N2MVM2C175GP-S828
N2MVM3C175GP-S828

N2MVM2C150GR305-S828
N2MVM3C150GR305-S828
N2MVM2C175GR305-S828
N2MVM3C175GR305-S828

N2MVMJ150GP-S828
N2MVMJ175GP-S828

N2MVMJ150GR305-S828
N2MVMJ175GR305-S828

1.
Voltage
Suffix

2.

Multi Tap
/MT

STIBOINFO((CRH:66008com:3L:767))

CEC/CSA (cUL)
Tri Tap
/TT

Optional Voltage Ballasts - 50 or 60Hz
EXPORT
Voltage
220V 60Hz
220V 50Hz
230V 50Hz
Suffix
/220
/220 50
/230 50
Options - Add the required options suffixes from page 765, In Alpha-numeric order

US: 1-866-764-5454

CH0 3 L - 3 0

Standard Voltage Ballasts - 60Hz
NEC/UL
120V
480V
/120
/480

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

120V
/120

240V 50Hz
/240 50

767

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0768-3 Name: 3L-768

3L

DATE: JAN 19 2006

Time: 5:50:02 PM Operator: RB

COLOR: CMYK

TCP: 15001

ɀ

Cl. II Groups F, G, Cl. III
& Simultaneous Presence
(100W max)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP56

ɀ

70-175W Metal
Halide

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div
2 & Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

N2MV Series
Champ® H.I.D. Luminaires

Typedriver Name: TS name csm no.: 100

See notes 1 (to specify voltage), 2 and 3. For guards and other optics see N2MV Luminaires - Ordering by Components Section.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Ceiling Mount
Thru-Feed

Stanchion Mount
25° Angle

Hub
Size
3⁄4
1
3⁄4
1
3⁄4
1

3⁄4

Lamp
Watts
70
100
175

70

1
3⁄4
1
3⁄4
1

100
175

11⁄2
11⁄2
11⁄2

070
100
175

With G303 Globe and
P33 Guard Cat. No.
N2MVM2A070GP
N2MVM3A070GP
N2MVM2A100GP
N2MVM3A100GP
N2MVM2A175GP
N2MVM3A175GP

With GR305 Glass
Refractor Cat. No.
N2MVM2A070GR305
N2MVM3A070GR305
N2MVM2A100GR305
N2MVM3A100GR305
N2MVM2A175GR305
N2MVM3A175GR305

N2MVM2C070GP
N2MVM3C070GP
N2MVM2C100GP
N2MVM3C100GP
N2MVM2C175GP
N2MVM3C175GP

N2MVM2C070GR305
N2MVM3C070GR305
N2MVM2C100GR305
N2MVM3C100GR305
N2MVM2C175GR305
N2MVM3C175GR305

N2MVMJ070GP
N2MVMJ100GP
N2MVMJ175GP

N2MVMJ070GR305
N2MVMJ100GR305
N2MVMJ175GR305

100-175W Mercury
Vapor
N2MV Series
Champ® H.I.D. Luminaires

ɀ Cl. II Groups F, G, Cl. III
& Simultaneous Presence
(100W max)
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP56

ɀ Cl. I, Div 2, Groups A, B, C, D
ɀ Restricted Breathing Cl. I, Div
2 & Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)

BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Ceiling Mount
Thru-Feed

Stanchion Mount
25° Angle

Hub
Size
3⁄4
1
3⁄4
1

Lamp
Watts
100
175

3⁄4

100

1
3⁄4
1

175

11⁄2
11⁄2

100
175

With G303 Globe and
P33 Guard
N2MVC2A100GP
N2MVC3A100GP
N2MVC2A175GP
N2MVC3A175GP

With GR305
Glass Refractor
N2MVC2A100GR305
N2MVC3A100GR305
N2MVC2A175GR305
N2MVC3A175GR305

N2MVC2C100GP
N2MVC3C100GP
N2MVC2C175GP
N2MVC3C175GP

N2MVC2C100GR305
N2MVC3C100GR305
N2MVC2C175GR305
N2MVC3C175GR305

N2MVCJ100GP
N2MVCJ175GP

N2MVCJ100GR305
N2MVCJ175GR305

1.
Voltage
Suffix

Multi Tap
/MT

Standard Voltage Ballasts - 60Hz
NEC/UL
120V
480V
/120
/480

CEC/CSA (cUL)
Tri Tap
/TT

Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts

2.
3.

768

STIBOINFO((CRH:66008com:3L:768))
CH0 3 L - 3 0

Voltage
208V CWI
240V CWI
600V CWI
Suffix
/208CWI
/240CWI
/600CWI
70W Ballast not available in 480V.
Options - Add the required options suffixes from page 765, in Alpha-numeric order.

US: 1-866-764-5454

CAN: 1-800-265-0502

120V
/120

EXPORT
220V 60Hz
/220

220V 50Hz
/220 50

Copyright© 2006 Cooper Crouse-Hinds

230V 50Hz
/230 50

240V 50Hz
/240 50

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0769-3 Name: 3L-769

100:
DATE: JAN 19 2006

Time: 5:50:03 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

N2MV Luminaires Ordering by Components

3L

N2MV luminaires are available in components
A complete luminaire consists of:
I.
N2MV Cover (mounting module)
II.
N2MV Ballast Housing - Include voltage and required option(s)
III.
Globe, Refractor, Guard, Reflector

I. N2MV Cover (Mounting Module):
Type
Pendant

Conduit
3⁄4

Ceiling
Wall (Use wall bracket accessory with
Ceiling Cover)
Stanchion - 25 Degree Angle

1
3⁄4
1
3⁄4
1
11⁄2

Cat. No.
N2APM2
N2APM3
N2CM2
N2CM3
N2MV - WM1 and N2CM2
N2MV - WM1 and N2CM3
N2JM5

II. Ballast Housings. Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Type
High Pressure Sodium

Metal Halide
Mercury Vapor

Lamp
Watts
50
70
100
150
70
100
175
100
175

Catalog Number
N2MVS050/MT
N2MVS070/MT
N2MVS100/MT
N2MVS150/MT LX
N2MVM070/MT
N2MVM100/MT
N2MVM175/MT
N2MVC100/MT
N2MVC175/MT

III. Globe, Refractors, Guards and Reflectors
Type
Globe
Globe Teflon Coated
Globe Guard
Reflector-Dome
Reflector-Angle
Refractor - Type 2
Refractor - Type 5
Refractor Guard
Large Plastic Refractor Type 2
Large Plastic Refractor Type 3
Large Plastic Refractor Type 5

Catalog Number
G303
G303-S808
P33
RD739
RA739
GR302
GR305
P23
PGR302
PGR303
PGR305

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:769))
CH0 3 L - 3 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

769

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0770-1 Name: 3L-770

3L

100:
DATE: JAN 19 2006

Time: 5:50:04 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Family Tree

50-175W N2MV Series
Non-Metallic Champ® H.I.D Luminaires

N2MV Champ Series Luminaire
A complete luminaire consists of a cover mount, a ballast housing and a globe,
with or without guard, refractor or reflector.

* These plastic refractors are for non-hazardous areas only (50–100W max.)

770

STIBOINFO((CRH:66008com:3L:770))
CH0 3 L - 3 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0771-1 Name: 3L-771

DATE: JAN 19 2006

Time: 5:50:05 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Temperature Performance Data

50-175W N2MV Series

3L

®

Champ H.I.D Luminaires

Lamp
Watts

Ambient
Temp C

Optics

Class I
(Gas/Vapors)

Class II
(Dust)
and
Class III

Non
Restricted
Breathing

Restricted
Breathing

Standard
Product

Option
S826(TB)

Division 2

Zone 2 or
Division 2

G303

X

X

GR305

X

X

T3A
T3A
–
T3A
T3A
–
T2D
T2C
–
T2C
–
–

Simultaneous
Presence
Gas and Dust Present in
the Same Area

Supply
Wire
Temp
C

Non
Restricted
Breathing

Restricted
Breathing

Standard
Product

Option
S826

Class I,
Division 2
and
Class II

Class I, Zone 2
or Division 2
and
Class II

X

X

X

X

X

X

T5
T5
–
T5
T5
–
T5
T4
–
T4
–
–

T4A
–
–
T4A
–
–
T4A
–
–
–
–
–

T2C/T4A
–
–
T2C/T4A
–
–
T2C/T4A
–
–
–
–
–

T4A
–
–
T4A
–
–
T4A
–
–
–
–
–

75
85
–
75
85
–
85
100
–
85
–
–

T3C
T3B
–
T2B
T2B
–
T2
–
–
T2
–
–

T5
T5
–
T4
T4
–
T3
–
–
T3
–
–

T4
–
–
T4
–
–
–
–
–
–
–
–

T2B/T4
–
–
T2B/T4
–
–
–
–
–
–
–
–

T4
–
–
T4
–
–
–
–
–
–
–
–

75
85
–
85
–
–
–
–
–
–
–
–

T2B
T2B
–
T2
–
–

T4
T4
–
T3
–
–

T4
–
–
–
–
–

T2B/T4
–
–
–
–
–

T4
–
–
–
–
–

75
85
–
85
–
–

US: 1-866-764-5454

CAN: 1-800-265-0502

Ex nR

Ex nR
Standard
Product

High Pressure Sodium
50

70

100

150

40
55
65
40
55
65
40
55
65
40
55
65

Metal Halide
70

100

150
(S828)
175
(Includes
S828)

40
55
65
40
55
65
40
55
65
40
55
65

Mercury Vapor
100

175

STIBOINFO((CRH:66008com:3L:771))
CH0 3 L - 3 0

40
55
65
40
55
65

Copyright© 2006 Cooper Crouse-Hinds

771

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0772-1 Name: 3L-772

3L

DATE: JAN 19 2006

Time: 5:50:05 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Dimensions and Weights

50-175W N2MV Series

Champ® H.I.D. Luminaires
Non-Metallic

N2MV Dimensions
Ceiling Mount

Ceiling Mount – Top View

25° Angle Stanchion Mount

Pendant Mount

Net Luminaire Weights (lbs.)
Wall Arm Mount

772

STIBOINFO((CRH:66008com:3L:772))
CH0 3 L - 3 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Luminaire with
Luminaire with
Globe, Guard
Luminaire Lamp Globe, Guard Lamp
Series
Watts (lbs.)
Watts
(lbs.)
N2MVS 50
23
70
231⁄16
100
241⁄16
150
261⁄8
N2MVC 100
211⁄16
175
221⁄4
250
24
N2MVM 70
21
100
211⁄16
175
221⁄4
250
24
Add for mounting modules (lbs.):
Pendant
11⁄4
Flexible Pendant
11⁄2
Ceiling
23⁄4
Wall
41⁄2
Quad Mount
31⁄2
Angle Stanchion
31⁄2
Straight Stanchion 41⁄2
Add for reflectors (lbs.):
Dome
11⁄4
30° Angle
13⁄4
Deduct: 1 lb. for luminaire without P33 Guard.
Add: 51⁄2 lbs. for luminaire with GR305 refractor.

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0773-2 Name: 3L-773

100:
DATE: JAN 19 2006

Time: 5:50:07 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

50-175W N2MV Series

3L

Champ® H.I.D. Luminaires
Non-Metallic

Lamp: 150W/E-23-1/2 clear high pressure sodium (HPS)
Total bare lamp lumens: 16000
To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689.
NOTE: All data provided is for high pressure sodium luminaires with 150W/E-231⁄2 clear lamps. Use
conversion factors (multipliers) shown below for other clear lamp types and wattages. Consult Cooper
Crouse-Hinds for additional photometric data on any Champ series luminiares.

Luminaire with Globe and Dome Reflector
Multipliers: (for use with
candela curves only).

Isofootcandle Chart: Luminaire with Globe and Dome
Reflector

ConLuminaire Lamp version
Series
Watts Factor
N2MVS
50
0.25
70
0.40
100
0.59

Luminaire spacing ratio: 1.90

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.759
.643
.551
80
30
.719
.582
.480
10
.683
.530
.424
50
.740
.627
.538
70
30
.703
.570
.471
10
.669
.523
.418
50
.703
.595
.512
50
30
.672
.548
.455
10
.645
.506
.408
50
.669
.567
.488
30
30
.646
.528
.439
10
.622
.492
.399
50
.640
.541
.466
10
30
.619
.508
.424
10
.600
.479
.389
0
0
.582
.459
.370

4
.476
.400
.342
.465
.394
.338
.442
.381
.332
.422
.368
.325
.403
.356
.318
.299

5
.418
.340
.283
.406
.334
.280
.388
.324
.276
.370
.314
.270
.354
.305
.265
.247

% Reflectance
Eff. Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

9
.267
.198
.151
.262
.195
.151
.250
.190
.148
.240
.184
.146
.231
.180
.143
.128

10
.231
.164
.121
.226
.164
.121
.218
.159
.119
.209
.154
.116
.201
.150
.114
.100

Room Cavity Ratio
6
7
8
.371
.330
.294
.296
.257
.224
.243
.208
.174
.362
.323
.288
.291
.252
.221
.238
.204
.173
.345
.309
.275
.283
.244
.215
.235
.201
.170
.331
.294
.265
.275
.239
.208
.231
.196
.168
.317
.284
.253
.266
.233
.203
.227
.193
.165
.210
.177
.149

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:773))
CH0 3 L - 3 3

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with Globe and 30°
Angle Reflector

Isofootcandle charts show illumination in footcandles on work plane 10
feet below light center. Multiply by factor shown to convert to other
mounting heights.
Height (Ft.)
Factor
Height (Ft.)
Factor
8
1.56
16
.391
12
.694
20
.250
14
.510

Copyright© 2006 Cooper Crouse-Hinds

773

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0774-2 Name: 3L-774

3L

100:
DATE: JAN 19 2006

Time: 5:50:08 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

50-175W N2MV Series

Champ® H.I.D. Luminaires
Non-Metallic

Lamp: 175W/E-28 coated mercury vapor (MV)
Total bare lamp lumens: 8600
To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689.
NOTE: All data provided is for mercury vapor luminaires with 175W/E-28 diffuse lamps. Use conversion
factors (multipliers) shown below for other diffuse lamp types and wattages. Consult Cooper CrouseHinds for additional photometric data on any Champ series luminaire.

Luminaire with Globe and Dome Reflector
Multipliers: (for use with
candela curves only).

Isofootcandle Chart: Luminaire with Globe and Dome
Reflector

ConLuminaire Lamp version
Series
Watts Factor
N2MVC
100
0.49
250
1.41
N2MVM

175
250

1.63
2.38

Luminaire spacing ratio: 1.7

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil. Wall
1
2
3
50
.723
.619
.536
80
30
.684
.561
.470
10
.649
.512
.417
50
.705
.604
.524
70
30
.668
.549
.461
10
.635
.505
.412
50
.668
.572
.498
50
30
.638
.528
.445
10
.611
.488
.401
50
.635
.545
.474
30
30
.611
.508
.429
10
.588
.474
.391
50
.606
.519
.453
10
30
.585
.488
.414
10
.566
.460
.381
0
0
.549
.442
.363

4
.467
.396
.342
.456
.390
.338
.434
.377
.331
.414
.365
.324
.395
.352
.317
.299

5
.412
.340
.286
.401
.334
.283
.384
.324
.279
.366
.314
.273
.350
.305
.268
.251

% Reflectance
Eff. Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

9
.269
.204
.160
.263
.201
.159
.252
.196
.157
.243
.190
.154
.233
.186
.151
.138

10
.234
.172
.131
.229
.171
.131
.221
.166
.128
.212
.162
.126
.205
.157
.123
.110

774

STIBOINFO((CRH:66008com:3L:774))
CH0 3 L - 3 4

Room Cavity Ratio
6
7
8
.368
.329
.294
.298
.261
.229
.248
.215
.182
.359
.322
.289
.293
.256
.226
.244
.211
.181
.343
.308
.276
.284
.248
.220
.240
.207
.178
.329
.294
.266
.276
.243
.213
.236
.203
.176
.315
.284
.255
.268
.236
.208
.231
.200
.173
.216
.184
.158

US: 1-866-764-5454

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with Globe and 30°
Angle Reflector

Isofootcandle charts show illumination in footcandles on work plane 10
feet below light center. Multiply by factor shown to convert to other
mounting heights.
Height (Ft.)
Factor
Height (Ft.)
Factor
8
1.56
16
.391
12
.694
20
.250
14
.510

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0775-2 Name: 3L-775

DATE: JAN 19 2006

Time: 5:50:08 PM Operator: JB

Champ® H.I.D. Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Accessories

3L

VMV, LMV, DMV, VMV High Wattage &
N2MV Series

Globes

Reflectors

G54

Dome – Krydon® material

30° Angle –
Krydon material

G24
G303
Lamp
Watts
35-150
50-175
50-250
200-400
250
50-175

Luminaire Series
LMVS, LMVM
VMVC, VMVM, VMVS
DMVC, DMVM, DMVS
VMVS
VMVC, VMVM
N2MVC, N2MVM,
N2MVS

Lamp Watts
35-150

Type
Heat/impact resistant
Heat/impact resistant
Heat/impact resistant
Heat/impact resistant
Heat/impact resistant

Cat. #
G54
G24
G303
G303
G303

50-175
50-250

Heat/impact resistant

G303

50-175

200-400
250

Luminaire Series
LMVS, LMVM

Dome Cat. #
RD636
(RD66)
VMVC, VMVM, VMVS RD70
DMVC, DMVM, DMVS RD739
(RD79)
VMVS
RD739
(RD79)
VMVC, VMVM
RD739
(RD79)
N2MV, N2MVF(B)
RD739

Angle Cat. #
RA636
(RA66)
RA70
RA739
(RA79)
RA739
(RA79)
RA739
(RA79)
RA740

Guards

P50 – use with
G54 globe

Reflector/Lens – Etched Alzak
aluminum reflector/tempered
glass lens
P21 – use with
G24 globe
P33 – use with
G303 globe

Lamp Watts
200-400
70-250

Luminaire Series
VMVC, VMVM,
VMVS
DMVS, DMVC,
DMVM

Type
Reflector/Lens

Cat. #
GRD4

Reflector/Lens

GRD4

Globes – Teflon Coated
Teflon coated for increased shatter protection
Lamp Watts
50-175
50-175

P23 – use with
refractors
Lamp
Watts
35-150
50-175
50-250
200-400
250
Refractors
50-175

Luminaire Series
LMVS, LMVM
VMVC, VMVM, VMVS
DMVC, DMVM, DMVS
VMVS
VMVC, VMVM
All
N2MVC, N2MVM,
N2MVS

Type
Copper-free aluminum
Copper-free aluminum
Stainless steel
Stainless steel
Stainless steel
Stainless steel

Cat. #
P50
P21
P33
P33
P33
P23

Stainless steel

P33

Luminaire Series
VMVC, VMVM, VMVS
DMVC, DMVM, DMVS

Cat. #
G24-S808
G303-S808

Alzak is a registered trademark of Alcoa.
Teflon is a registered trademark of E.I. DuPont Co.

 – available with Lightning Service TM delivery.
See Section G. for complete details.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:775))
CH0 3 L - 3 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

775

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0776-1 Name: 3L-776

DATE: JAN 19 2006

Time: 5:50:11 PM Operator: JB

Champ® H.I.D. Luminaires

3L

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Accessories

VMV, DMV & VMV High Wattage
and N2MV Series

Safety Lighting Options

Refractors

Quartz Auxiliary Lamp

R2, R5, PR2, PR3, PR5

Lamp
Watts
50-175

200-400

50-250

50-175

GR302, GR305

Luminaire
Series
VMVC, ⎫
VMVM, ⎬
VMVS ⎭

I.E.S.
Type
II
III
V

Glass
Cat. #
R2

VMVC, ⎫
VMVM, ⎬
VMVS ⎭

II
V

GR302
GR305

II
III
V

GR302

DMVC,
DMVS,
DMVM
N2MV

⎫
⎬
⎭

R5

GR305

Plastic
(100W max.
non
hazardous)
Cat. #
PR2
PR3
PR5

Instant Restrike

PGR302
PGR303
PGR305

Type II

Factory installed instant restrike device will restart a hot high pressure
sodium lamp (50-150W LX) after a momentary power interruption,
without the typical delay for cooling.
Instant restrike for use in 50-150W ‘‘LX’’ HPS luminaires.
Add suffix IR to Cat. No.

Ballast-gard TM
Ballast-gard starter cut-out switch prevents starter pulsing after a time
delay of approximately two minutes if the lamp fails to start. For use in
50-400 watt HPS luminaires only. Add suffix BG to Cat. No.

I.E.S. Distribution Curves

Type I

The quartz auxiliary lamp comes to full brightness instantly and
remains lit until the H.I.D. lamp attains 60-70% of full illumination.
Quartz auxiliary lamps can be used with all DMV, VMV and VMV high
wattage series Champ® luminaires. Use for non-hazardous
applications ONLY.
(NOTE: VMV luminaires (50-175W) ordered with this option must use
large glass refractor optics, not compact refractors).
Quartz auxiliary lamp (100W single ended lamp – Q100CL/DC,
Q100DC or 100Q/CL/DC NOT furnished)
Add suffix QTZ to Cat. No.

Type III

Type V

Compact Refractors

G241, G245
With optional P241 wire guard.
Luminaire
IES
Glass
Series
Type
Cat. #
VMVC, ⎫
I
G241
VMVM, ⎬
V
G245
VMVS ⎭
Optional stainless steel wire guard
P241

Lamp
Watts
50-175

776

STIBOINFO((CRH:66008com:3L:776))
CH0 3 L - 3 6

US: 1-866-764-5454

CAN: 1-800-265-0502

 – available with Lightning Service TMdelivery.
See Section G for complete details

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0777-1 Name: 3L-777

100:
DATE: JAN 19 2006

Time: 5:50:13 PM Operator: JB

ɀ

V2PC Photocell

ɀ

COLOR: CMYK

TCP: 15001

Cl. I, Div. 2, Groups A,B,C,D
Maintains Cl. I, Div 2
Suitability of Cooper Crouse-Hinds
Champ® Series Luminaires

Typedriver Name: TS name csm no.: 100

3L

The only UL recognized photocell for
Class I, Division 2 areas eliminates the
need for an explosionproof box.
When mounting in EIH enclosures for
Class I, Division 1 applications (EV21H
Series) seals are not required for Groups
C & D.
Cooper Crouse-Hinds V2PC factory-sealed,
field installed photocell offers reliable, duskto-dawn lighting control in Class I, Division 2
locations. The V2PC is ideal for walkways,
security lighting, and any other outdoor
lighting application that utilizes Champ®
H.I.D. lighting luminaires.

Applications:
The V2PC is designed:
ɀ to provide control for automatic dusk-todawn lighting.
ɀ for use with LMV, DMV, VMV, VMV High
Wattage, N2MV and FMV Series Champ®
lighting luminaires.
ɀ for use on 35-400 watt H.I.D., incandescent,
or fluorescent lighting luminaires.
ɀ to save energy by operating luminaires only
when necessary.
ɀ for safety by turning on outdoor luminaires
in critical passageways at night.
ɀ for walkways, parking areas, outdoor
process areas, security lighting, or any
outdoor lighting application in Class I,
Division 2 locations and corrosive
environments.
ɀ for remote mounting in FS boxes (D2S
Series).
ɀ for mounting in EIH enclosures for Class I,
Division 1 applications (EV2IH Series).

Features:
ɀ Field-installable.
ɀ Solid-state design for performance and
dependability.
ɀ Factory sealed components.
Explosionproof enclosure not required for
Class I, Division 2 locations.
ɀ Luminaires turn on at 3 footcandles, off at 8
footcandles insuring that the luminaires are
operating only when needed.
ɀ Built-in 10 second time delay to eliminate
nuisance tripping.
ɀ Eight-year operating life.
ɀ Furnished with 6⍯ stranded 600 volt color
coded wire leads.
ɀ Constructed from corrosion-resistant
thermoplastic polyester.
ɀ Available on a DS cover for use with any
FS/FD box (D2S Series).
ɀ Available in an EIH enclosure for use in
Class I, Division 1, Groups B†, C, and D
locations (EV2IH Series). No seals required.

Certifications and
Compliances:
V2PC and D2S
ɀ NEC/CEC: Class I, Division 2, Groups A, B,
C, D
ɀ UL Standard: 844 – Hazardous (Classified)
Locations
ɀ CSA: C22.2 No. 55
EV2IH
ɀ NEC/CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
ɀ NEMA: 3, 4, 7BCD, 9EFG
ɀ UL Standard: 844 – Hazardous (Classified)
Locations
ɀ CSA: C22.2 No. 30, 55

Options:
To order luminaire with photocell factory
installed:
1. Specify luminaire dedicated supply voltage
(not MT, DT, or TT)
2. Add photocell Cat. No. to fixture Cat. No.
as follows:
V2PC20
V2PC22
V2PC27
Example: VMVSJ070GP/120-V2PC20 is a
120V 60Hz luminaire with a factory installed
photocell.

Electrical Rating Ranges:
ɀ 120, 208, 220, 240, 277 VAC
ɀ 50/60 Hz
ɀ 35-400 watt H.I.D., incandescent, or
fluorescent
ɀ V2PC20 – 3.3A max. current rating
ɀ V2PC22 – 1.8A max. current rating
ɀ V2PC27 – 1.4A max. current rating
† For Group B applications, seal within 11⁄2⍯ of enclosure in
accordance with Section 501-5 of the National Electric
Code®.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3L:777))
CH0 3 L - 3 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

777

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0778-2 Name: 3L-778

3L

DATE: JAN 19 2006

Time: 5:50:14 PM Operator: RB

ɀ

V2PC Photocell

ɀ

Dimensions
Ordering Information

COLOR: CMYK

TCP: 15001

Cl. I, Div. 2, Groups A,B,C,D
Maintains Cl.I, Div. 2
Suitability of Cooper Crouse-Hinds
Champ® Series Luminaires

Dimensions:
V2PC

D2S

EV2IH

Cat. #
EV2IH

a
5.00

b
4.25

c
2.60

d
4.54

e
5.25

Ordering Information
Photocell for field installation*
Catalog #
V2PC20
V2PC22
V2PC27

Voltage Range
120V, 50/60 Hz
208-240V, 50/60 Hz
277V, 50/60 Hz

* Must be factory installed in Canada — see page 777.

Photocell in DS cover for use with FS/FD box
Catalog #
Voltage Range
D2S20
120V, 50/60 Hz
D2S22
208-240V, 50/60 Hz
D2S27
277V, 50/60 Hz

Photocell in EIH enclosure for use in Class I,
Division 1, Groups B, C, and D; Class II,
Division 1, Groups E, F, and G; and Class III
locations
Catalog #
Voltage Range
EV2IH20
120V, 50/60 Hz
EV2IH22
208-240V, 50/60 Hz
EV2IH27
277V, 50/60 Hz

778

STIBOINFO((CRH:66008com:3L:778))
CH0 3 L - 3 8

US: 1-866-764-5454

CAN: 1-800-265-0502

Typedriver Name: TS name csm no.: 100

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0779-2 Name: 4L-779

100:
DATE: JAN 19 2006

Time: 5:50:16 PM Operator: RB

COLOR: CMYK

TCP: 15001

High Intensity Discharge
(H.I.D.) Luminaires
Hazardous

Typedriver Name: TS name csm no.: 100

4L

Description

Page No.

Application/Selection

780

Class I Hazardous Area Lighting
Integrally Ballasted Luminaires

EVLP Lo-ProTM Hazard ȿ Gard® Series
EVM Hazard ȿ Gard® Series
HPS, Pulse Start MH, MH, MV

781-791
792-800

Class II Hazardous Area Lighting
Integrally Ballasted Luminaires

EVLP Lo-ProTM Hazard ȿ Gard® Series
EVM Hazard ȿ Gard® Series
HPS, Pulse Start MH, MH, MV

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4L:779))
CH0 0 0 0 5 L

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

781-791
792-800

779

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0780-2 Name: 4L-780

4L

DATE: JAN 19 2006

Time: 5:50:16 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

High Intensity Discharge
(H.I.D.) Luminaires
Hazardous Application and Selection
Quick Selector Chart

Application:
Luminaires contained in this section are for
use:
ɀ in indoor or outdoor hazardous locations
ɀ as general area or spot lighting applications
ɀ where longer lamp life provides desirable
maintenance cost savings and return on
investment through use of fewer luminaires,
circuits and ancillary apparatus
ɀ where relamping and maintenance
difficulties require longer lamp life

Table 500-3(d)
Identification Numbers.
Maximum
Temperature
Deg. C
Deg. F
450
842
300
572
280
536
260
500
230
446
215
419
200
392
180
356
165
329
160
320
135
275
120
248
100
212
85
185

Considerations for
Selection:
Environmental:
ɀ Make sure luminaire meets NEC/CEC
requirements for area in which it will be used
Lighting levels required:
ɀ Can luminaire accept lamp of sufficient size
to yield desired light level (see Lighting
Selector Guide to determine the number and
location of luminaires required)
NOTE: For details on luminaire selection and
methods for determining number and
location luminaires, see Lighting Selector
Guide, pages 665 to 689.

Identification
Number
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

Quick Selector Chart
Series

Electrical Characteristics
Watts

Cl. I, Groups B, C, D

Volts

Ballast

50, 70, 100, 150,
175, 200, 250, 320, 400
(Mogul base)

120, 208, 240, 277,
347, 480, 600, MT

High power factor,
constant wattage, reactor
or autotransformer

Cl. II, Groups E, F, G

50, 70, 100, 150,
175 (Mogul base)

120, 208, 240, 277,
347, 480, 600, MT

integral

Champ® Series
(see Section 3L)

Cl. II, Groups E, F, G

70, 100, 150, 175
(Mogul base)

120, 208, 240, 277,
347, 480, 600, MT

High power factor,
constant wattage integral

EVLP
Hazard ȿ Gard TM

Cl. I, Groups B, C, D

70, 100, 150, 175
(Medium base)
70, 100, 150, 175,
200, 250
(Mogul base)

120, 208, 240, 277,
347, 480, MT, TT

High power factor,
constant wattage, reactor
or autotransformer,
integral.

Cl. II, Groups E, F, G
Cl. III

70, 100
(Medium base)
70, 100, 150, 175
(Mogul base)

120, 208, 240, 277,
347, 480, MT, TT

EVM
Hazard ȿ Gard TM

780

STIBOINFO((CRH:66008com:4L:780))
CH0 0 5 L - 0

NEC
Compliance

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0781-4 Name: 4L-781

100:
DATE: JAN 19 2006

Time: 5:50:17 PM Operator: JB

EVLP Low Profile Hazard ȿ Gard®
(H.I.D.) Luminaires
Medium and Mogul Base

COLOR: CMYK

ɀ

TCP: 15001

Cl. I, Div. 1, Groups B (GB suffix), C, D
Cl. I, Zone 1 Groups IIB + H2
(with suffix – GB), IIB, IIA
ɀ Cl. II, Div. 1 Groups E, F, G; Class III,
Simultaneous Presence (175W max)
ɀ

Typedriver Name: TS name csm no.: 100

ɀ

Marine & Wet
Locations
ɀ 3,3R, 4,4X; IP66

4L

Application:
Cooper Crouse-Hinds Low Profile
Hazard ȿ Gard® luminaires are used in:
ɀ areas where flammable or explosive vapors
or gases are present
ɀ hazardous areas, both indoors and
outdoors, where long life and low
maintenance costs are desired
ɀ petroleum refineries, chemical,
petrochemical and pharmaceutical plants, oil
terminals, gas plants and other heavy
process industry facilities
ɀ waste treatment facilities
ɀ drilling platforms and other coastal and
offshore hazardous areas

Features - Benefits:
ɀ Small compact size is perfect where low
mounting restrictions are a concern.
ɀ Two start Acme threaded construction
allows for easier assembly, installation and
maintenance.
ɀ Light weight copper-free aluminum housing
with powdered epoxy finish for superior
corrosion resistance.
ɀ All exterior hardware is corrosion-resistant
stainless steel.
ɀ Four mounting arrangements; pendant,
ceiling, wall bracket and stanchion suit any
lighting layout.
ɀ Wide range of light sources and wattages
to meet specific lighting needs.
ɀ Marine and Nema 4X construction suitable
for outdoor, hose down, marine and
corrosive environments.
ɀ Integral ballast for lowest installed cost.
ɀ High power factor (90%+) ballasts allows
more fixtures per circuit.
ɀ Uses same mounting modules as the
standard Hazard ȿ Gard® for easy retrofitting
when the Lo-Pro TM is the preffered choice.
ɀ Internally fluted glass globe reduce glare
and distributes light evenly – ideal for adverse
enviroments typical of industrial facilities.
ɀ Krydon® construction dome and angle
reflectors – won’t rust, corrode, dent, chip or
peel
ɀ Now available in components – luminaire
body, mounting module, guard, reflectors –
allowing for easy stocking for Quick Ship
requirements.

Standard Materials:
ɀ Mounting modules, cover, ballast housing,
globe holder – copper free aluminum
ɀ Globe – heat and impact resistant glass
ɀ Exterior hardware – stainless steel
ɀ Reflectors (dome & angle) – Krydon TM
fiberglass-reinforced polyester
* When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

Standard Finishes:
Copper-free aluminum – Corro-free TM
powdered epoxy
ɀ Krydon – white
ɀ Stainless steel guard

Ratings (Electrical/Size):
Sources/wattage:
ɀ Medium Base 70-150W HPS, 70-175W MH
ɀ Mogul Base 70-150W HPS, 70-250W MH
Voltages:
ɀ Medium & Mogul H.I.D.
120V 60Hz
Multi-tap (120, 208, 240, 277V 60Hz)
Tri-tap (120, 277, 347V 60Hz)
480V 60Hz
Other voltages – consult Cooper CrouseHinds
Conduit entries:
ɀ 3⁄4⍯, 1⍯ NPT – pendant, wall bracket, ceiling
ɀ 11⁄4⍯ NPT – stanchion

Certification &
Compliances:
ɀ NEC and CEC:
- Class I, Division 1, Groups B
(with suffix GB), C, D – All Wattages
- Class I, Zone 1 Groups IIB + H2
(with suffix GB), IIB, IIA – All Wattages
- Class II, Class III & Simultaneous
Presence – (medium base 100 watt max.,
Mogul Base 175 watt max.)
ɀ UL Standards:
- 844, Hazardous (Classified) Locations
- 1598 Luminaires
- 1598A Marine Locations
ɀ CSA Standards
- C22.2 No. 137

Options:
Description
Group B suitability
BallastGard (HPS only)
Instant restrike (Mogul Base only)
70-150W LX HPS
Cannot use with BG Option
Fused
Quartz auxiliary lighting (Mogul Base only)
Cannot use with IR option
Uses 100W single ended double contract lamp
Quartz lamp not included
Factory assembled with lamps

Suffix to be added to Cat. #
GB
BG
IR
S658*
QTZ

FA

Accessories:
Description
Dome reflector
Angle reflector
US: 1-866-764-5454

STIBOINFO((CRH:66008com:4L:781))
CH0 0 5 L - 1

CAN: 1-800-265-0502

Cat. #
RD739
RA739
Copyright© 2006 Cooper Crouse-Hinds

781

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0782-5 Name: 4L-782

4L

DATE: JAN 19 2006

Time: 5:51:21 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

ɀ

Cl. I, Div. 1, Groups B(GB suffix),C,D
Cl. I, Zone 1 Groups IIB + H2
(With Suffix GB), IIB, IIA
ɀ Cl. II, Div. 1, Groups E, F, G; Class III,
Simultaneous Presence (100W max)

EVLP Low Profile
Hazard ȿ Gard®

Marine & Wet
Locations
ɀ 3, 3R, 4, 4X; IP66

ɀ

Medium Base

Medium Base Ordering Information

Hub
Size

Watt

Pendant
With Guard
Catalog #

Wall Brckt
With Guard
Catalog #

Ceiling
With Guard
Catalog #

EVLPA142071
EVLPA143071

EVLPBX142071
EVLPBX143071

EVLPCX142071
EVLPCX143071

EVLPA142101
EVLPA143101

EVLPBX142101
EVLPBX143101

EVLPCX142101
EVLPCX143101

EVLPA142151
EVLPA143151

EVLPBX142151
EVLPBX143151

EVLPCX142150
EVLPCX143151

Luminaire Body
Less Mounting
Module & Guard

Stanchion
With Guard
Catalog #

Catalog #

High Pressure Sodium
3⁄4

70W

1
11⁄4
3⁄4
1
11⁄4
3⁄4
1
11⁄4

100W

Pendant Mount

150W

EVLP14070
EVLPJ144071
EVLP14100
EVLPJ144101
EVLP14151
EVLPJ144151

Pulse Start Metal Halide
150W

3⁄4

175W

1
11⁄4
3⁄4
1
11⁄4

EVLPA192151-S828 EVLPBX192151-S828 EVLPCX192151-S828
EVLPA193151-S828 EVLPBX193151-S828 EVLPCX193151-S828

EVLP19150-S828
EVLPJ194151-S828

EVLPA192171-S828 EVLPBX192171-S828 EVLPCX192171-S828
EVLPA193171-S828 EVLPBX193171-S828 EVLPCX193171-S828

EVLP19175-S828
EVLPJ194171-S828

Metal Halide
3⁄4

70W

†Wall Bracket
Mount

1
11⁄4
3⁄4
1
11⁄4
3⁄4
1
11⁄4

100W

175W

EVLPA192071
EVLPA193071

EVLPBX192071
EVLPBX193071

EVLPCX192071
EVLPCX193071

EVLPA192101
EVLPA193101

EVLPBX192101
EVLPBX193101

EVLPCX192101
EVLPCX193101

EVLPA192171
EVLPA193171

EVLPBX192171
EVLPBX193171

EVLPCX192171
EVLPCX193171

EVLP19070
EVLPJ194071
EVLP19100
EVLPJ194101
EVLP19175
EVLPJ194171

Complete Catalog Number as follows:
1.

Standard Voltage Ballasts – 60HZ
NEC/UL
Voltage
Suffix

†Ceiling Mount

Multi-tap
/MT

120V
/120

CEC/CSA (cUL)

480V
/480

Tri-tap
/TT

Optional Voltage Ballasts– 50 Or 60HZ
*CEC/CSA (cUL)– CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

220V 60HZ
/220

Export
220V 50HZ
/220 50

2. 150W HPS Luminaires Only
ɀ 55V lamps – add suffix ‘‘LX’’
ɀ 100V lamps – add suffix ‘‘CE’’
* CWI Isolated Ballasts are only available for high pressure sodium and 175W metal halide (non pulse start) luminaires.

Stanchion Mount
†Ceiling and bracket mounts
have 4 hubs: 3 are plugged.

782

STIBOINFO((CRH:66008com:4L:782))
CH0 0 5 L - 2

US: 1-866-764-5454

CAN: 1-800-265-0502

120V
/120

Copyright© 2006 Cooper Crouse-Hinds

230V 50HZ
/230 50

240V 50HZ
/240 50

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0783-4 Name: 4L-783

DATE: JAN 19 2006

Time: 5:51:22 PM Operator: JB

COLOR: CMYK

TCP: 15001

ɀ

Cl. I, Div 1, Groups B (GB suffix), C, D
Cl. I, Zone 1 Groups IIB + H2
(with suffix GB), IIB, IIA
ɀ Cl. II, Div. 1, Groups E, F, G; Class III,
Simultaneous Presence (175W max)

EVLP Low Profile
Hazard ȿ Gard®

ɀ

Mogul Base

Typedriver Name: TS name csm no.: 100

ɀ

Marine & Wet
Locations
ɀ 3, 3R, 4, 4X; IP66

4L

Mogul Base Ordering Information

Hub
Size

Watt

Pendant
With Guard
Catalog #

Wall Bracket
With Guard
Catalog #

Ceiling
With Guard
Catalog #

EVLPA042071
EVLPA043071

EVLPBX042071
EVLPBX043071

EVLPCX042071
EVLPCX043071

EVLPA042101
EVLPA043101

EVLPBX042101
EVLPBX043101

EVLPCX042101
EVLPCX043101

EVLPA042151
EVLPA043151

EVLPBX042151
EVLPBX043151

EVLPCX042151
EVLPCX043151

Luminaire Body
Less Mounting
Module & Guard

Stanchion
With Guard
Catalog #

Catalog #

High Pressure Sodium
3⁄4

70W

1
11⁄4
3⁄4
1
11⁄4
3⁄4
1
11⁄4

100W

Pendant Mount

150W

EVLP04070
EVLPJ044071
EVLP04100
EVLPJ044101
EVLP04150
EVLPJ044151

Pulse Start Metal Halide
3⁄4

150W

1
11⁄4
3⁄4
1
11⁄4
3⁄4
1
11⁄4
3⁄4
1
11⁄4

175W

200W

†Wall Bracket
Mount

250W

EVLPA092151S828 EVLPBX092151S828 EVLPCX092151S828
EVLPA093151S828 EVLPBX093151S828 EVLPCX093151S828

EVLP09150S828
EVLPJ094151S828

EVLPA092171S828 EVLPBX092171S828 EVLPCX092171S828
EVLPA093171S828 EVLPBX093171S828 EVLPCX093171S828

EVLP09170S828
EVLPJ094171S828

EVLPA092201S828 EVLPBX092201S828 EVLPCX092201S828
EVLPA093201S828 EVLPBX093201S828 EVLPCX093201S828

EVLP09201S828
EVLPJ094201S828

EVLPA092251S828 EVLPBX092251S828 EVLPCX092251S828
EVLPA093251S828 EVLPBX093251S828 EVLPCX093251S828

EVLP09250S828
EVLPJ094251S828

Metal Halide
3⁄4

70W

1
11⁄4
3⁄4
1
11⁄4
3⁄4
1
11⁄4
3⁄4
1
11⁄4

100W

175W

250W

†Ceiling Mount

EVLPA092071
EVLPA093071

EVLPBX092071
EVLPBX093071

EVLPCX092071
EVLPCX093071

EVLPA092101
EVLPA093101

EVLPBX092101
EVLPBX093101

EVLPCX092101
EVLPCX093101

EVLPA092171
EVLPA093171

EVLPBX092171
EVLPBX093171

EVLPCX092171
EVLPCX093171

EVLPA092251
EVLPA093251

EVLPBX092251
EVLPBX093251

EVLPCX092251
EVLPCX093251

EVLP09070
EVLPJ094071
EVLP09100
EVLPJ094101
EVLP09170
EVLPJ094171
EVLP09250
EVLPJ094251

Complete Catalog Number as follows:
1.

Standard Voltage Ballasts – 60HZ
NEC/UL
Voltage
Suffix

Multi-tap
/MT

120V
/120

CEC/CSA (cUL)

480V
/480

Tri-tap
/TT

Optional Voltage Ballasts– 50 Or 60HZ
*CEC/CSA (cUL)– CWI Isolated Ballasts
Voltage
Suffix

Stanchion Mount
†Ceiling and wall bracket mounts
have 4 hubs:
3 are plugged.

208V CWI
/208CWI

STIBOINFO((CRH:66008com:4L:783))

600V CWI
/600CWI

220V 60HZ
/220

Export
220V 50HZ
/220 50

230V 50HZ
/230 50

240V 50HZ
/240 50

2. 150W HPS Luminaires Only
ɀ 55V lamps – add suffix ‘‘LX’’
ɀ 100V lamps – add suffix ‘‘CE’’
Example: EVLPA043151/MT-LX
* CWI Isolated Ballasts are only available for high pressure sodium and 175W–250W metal halide (non pulse start) luminaires.

US: 1-866-764-5454

CH0 0 5 L - 3

240V CWI
/240CWI

120V
/120

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

783

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0784-1 Name: 4L-784

DATE: JAN 19 2006

Time: 5:51:24 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

EVLP Low Profile
Hazard ȿ Gard®

4L

Ordering by Components

EVLP Luminaires are available in components. A complete
luminaire consists of:
ɀ Mounting Module
ɀ Luminaire Body
ɀ Guard, Dome Reflector or Angle Reflector

Mounting Modules
Type
Pendant

Conduit
3⁄4

1
3⁄4
1
Use EV22 or EV33 box with EV87
11⁄4

Ceiling & Wall Box
Wall Bracket Arm
Stanchion
Guards
Medium
Mogul
Reflectors
Dome
Angle

Catalog Number
EVMP2
EVMP3
EV22
EV33
EV87
EVMJ4
EV511
EV512
RD739
RA739

Pendant
EVMP2
EVMP3

Ceiling
EV22
EV33

Stanchion
EVMJ4

Ceiling
EV22
EV33

Wall Bracket
EV87 & EV22 or EV33

Luminaire Body
EVLP0 Series – H.I.D. Mogul Lamp
EVLP1 Series – H.I.D. Medium Lamp
(Refer to Ordering Information Page for
Complete Catalog No.)

Guards
EV511
EV512

784

STIBOINFO((CRH:66008com:4L:784))
CH0 0 5 L - 4

US: 1-866-764-5454

Dome Reflector
RD739

CAN: 1-800-265-0502

Angle Reflector
RA739

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0785-1 Name: 4L-785

DATE: JAN 19 2006

Time: 5:51:26 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Temperature Performance Data

EVLP Low Profile
Hazard ȿ Gard®

4L

Medium Base Lamp Luminaires

Maximum Ambient
High Pressure Sodium

Metal Halide
(including pulse start)

Class I, Group B
(w/GB suffix)
Groups C, D
40°C
55°C
T5
T4A
T4A
T4A
T4
T3C
T5
T4A
T3C
T3C
T3C
T3B
T3C
T3B

Watts
70W
100W
150W
70W
100W
150W
175W

65°C
T4A
T4
–
T4A
–
–
–

Class II, Groups E, F, G
Class III
Simultaneous
Presence
40°C
T4A
T4
–
T4
–
–
–

Supply Wire °C
90°C
90°C
90°C
85°C
90°C
90°C
90°C

65°C
T5
–
–
T5
T4A
–
–
–
–

Class II, Groups E, F, G
Class III
Simultaneous
Presence
40°C
T5
T4A
T4
T5
T4A
T3C
T3C
–
–

Supply Wire °C
90°C
90°C
90°C
85°C
90°C
90°C
90°C
90°C
90°C

Mogul Base Lamp Luminaires

Maximum Ambient
High Pressure Sodium

Metal Halide
(including pulse start)

Watts
70W
100W
150W
70W
100W
150W
175W
200W
250W

Class I, Group B
(w/GB suffix)
Groups C, D
40°C
55°C
T6
T5
T5
T4A
T4A
T4
T6
T5
T5
T4A
T4
T3C
T4
T3C
T3C
–
T3C
–

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4L:785))
CH0 0 5 L - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

785

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0786-1 Name: 4L-786

4L

100:
DATE: JAN 19 2006

Time: 5:51:27 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

EVLP Low Profile
Hazard ȿ Gard®
Dimensions and Weights

Dimensions (inches):
A
13.92
15.69

Medium Base
Mogul Base

B
12.73
14.69

C
16.50
18.25

D
16.71
18.46

E
20.59
22.34

Weights (lbs)
Source
High Pressure Sodium

Metal Halide

Watts
70
100
150
70
100
150
175
200
250

Add Mounting Modules:
Pendant
Ceiling
Bracket
Stanchion
Add For Reflectors
RA739
RD739
Deduct for Wire Guard

786

STIBOINFO((CRH:66008com:4L:786))
CH0 0 5 L - 6

US: 1-866-764-5454

Luminaire w/guard
Medium
34
36
36.5
33.5
34.5
36
36
–
–

Mogul
36.5
38.5
39
36
37
38.5
38.5
40.5
40.5

1
2
4.5
2.5

1
2
4.5
2.5

1
1
0.5

1
1
0.5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

F
19.36
21.30

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0787-1 Name: 4L-787

100:
DATE: JAN 19 2006

Time: 5:51:29 PM Operator: JB

COLOR: CMYK

TCP: 15001

Photometric Data

EVLP Low Profile
Hazard ȿ Gard®

Typedriver Name: TS name csm no.: 100

4L

Medium Base

Medium Base
Luminaire with Globe and Guard
EVLPA143151 Lamp: 150W/B17 High Pressure Sodium (HPS)
CANDELAS
Mid-Zone Angle

Candelas

0

1592

5

1005

15

952

25

1410

35

1194

45

1069

55

1252

65

1240

75

1442

85

1541

95

1571

105

789

115

33

125

6

Medium Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVLPA143150RD Lamp: 150W/B17 High Pressure Sodium (HPS)
CANDELAS

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4L:787))
CH0 0 5 L - 7

Mid-Zone Angle

Candelas

0

3019

5

2525

15

2645

25

2718

35

2349

45

2023

55

1967

65

1350

75

628

85

200

95

53

105

1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

787

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0788-1 Name: 4L-788

4L

100:
DATE: JAN 19 2006

Time: 5:51:31 PM Operator: JB

COLOR: CMYK

TCP: 15001

Photometric Data

EVLP Low Profile
Hazard ȿ Gard®
Medium and Mogul Base

Medium Base
Luminaire with Globe and 30° Angle Reflector (Less Guard)
EVLPA143150RA Lamp: 150W/B17 High Pressure Sodium (HPS)
CANDELAS
Degrees

Front

Side

Back

0

2722

2722

2722

5

2647

2026

1785

15

3047

2283

1754

25

2739

2457

1590

35

2709

1857

882

45

2739

1729

308

55

2483

1159

21

65

2421

790

0

75

2288

205

0

85

934

82

0

95

257

0

31

105

62

0

0

115

0

0

0

125

0

0

0

135

0

0

0

145

0

0

0

155

0

0

0

165

0

0

0

175

0

0

0

180

0

0

0

Mogul Base
Luminaire with Globe and Guard
EVLPA043151 Lamp: 150W/E231⁄2 High Pressure Sodium (HPS)
CANDELAS
Mid-Zone
Angle
Candelas
0
1944
5
1541
15
1167
25
1159
35
981
45
1035
55
1090
65
1348
75
1566
85
1619
95
1612
105
1226
115
265
125
19
135
10
145
7
155
6
165
0
175
0
180
0

788

STIBOINFO((CRH:66008com:4L:788))
CH0 0 5 L - 8

US: 1-866-764-5454

CAN: 1-800-265-0502

ZONAL LUMENS
With
Zone
Lumens
0-10
140
10-20
337
20-30
524
30-40
620
40-50
798
50-60
1030
60-70
1353
70-80
1640
80-90
1754
90-100
1749
100-110
1277
110-120
306
120-130
19
130-140
8
140-150
5
150-160
3
160-170
0
170-180
0

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0789-1 Name: 4L-789

100:
DATE: JAN 19 2006

Time: 5:51:32 PM Operator: JB

COLOR: CMYK

TCP: 15001

Photometric Data

EVLP Low Profile
Hazard ȿ Gard®

Typedriver Name: TS name csm no.: 100

4L

Mogul Base

Mogul Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVLPA043150RD Lamp: 150W/E231⁄2 High Pressure Sodium (HPS)
CANDELAS
Mid-Zone
Angle
Candelas
0
3568
5
3194
15
3097
25
3052
35
2420
45
2290
55
2044
65
1734
75
437
85
113
95
46
105
84
115
10
125
3
135
0
145
0
155
0
165
0
175
0
180
0

ZONAL LUMENS
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

Lumens
299
882
1379
1527
1767
1880
1662
480
127
49
81
14
4
0
0
0
0
0

Mogul Base
Luminaire with Globe and 30° Angle Reflector (Less Guard)
EVLPA043150RA Lamp: 150W/E231⁄2 High Pressure Sodium (HPS)
CANDELAS
Degrees
0
5
15
25
35
45
55
65
75
85
95
105
115
125
135
145
155
165
175
180

Front
Side
Back
3300
3300
3300
3369
3054
2446
3468
2553
1856
3299
2508
1526
2874
2189
1128
3150
2111
402
2920
1846
85
2907
2292
4
2880
1309
12
2454
80
19
1776
9
77
894
11
142
266
12
14
73
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
ZONAL LUMENS
Zone
Lumens
0-10
278
10-20
760
20-30
1138
30-40
1348
40-50
1502
50-60
1388
60-70
1317
70-80
1134
80-90
683
90-100
242
100-110
105
110-120
22
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4L:789))
CH0 0 5 L - 9

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

789

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0790-1 Name: 4L-790

4L

100:
DATE: JAN 19 2006

Time: 5:51:34 PM Operator: JB

COLOR: CMYK

TCP: 15001

Photometric Data

EVLP Low Profile
Hazard ȿ Gard®
Mogul Base

Mogul Base
Luminaire with Globe and Guard
EVLPA093171 Lamp: 175W/ED28 Metal Halide (MH)
CANDELAS
Mid-Zone
Angle
Candelas
0
2439
5
1750
15
1089
25
1017
35
915
45
917
55
1035
65
1229
75
1337
85
1359
95
1335
105
1196
115
390
125
24
135
12
145
9
155
0
165
0
175
0
180
0

ZONAL LUMENS
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

Lumens
158
313
464
563
732
922
1128
1377
1473
1452
1257
427
23
9
3
0
0
0

Mogul Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVLPA093170RD Lamp: 175W/ED28 Metal Halide (MH)
CANDELAS
Mid-Zone
Angle
Candelas
0
3941
5
3241
15
2651
25
2777
35
2219
45
2047
55
1880
65
1693
75
432
85
102
95
14
105
99
115
13
125
3
135
0
145
0
155
0
165
0
175
0
180
0

790

STIBOINFO((CRH:66008com:4L:790))
CH0 0 5 L 1 0

US: 1-866-764-5454

CAN: 1-800-265-0502

ZONAL LUMENS
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

Lumens
300
763
1249
1399
1594
1671
1466
466
121
20
88
16
2
0
0
0
0
0

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0791-1 Name: 4L-791

100:
DATE: JAN 19 2006

Time: 5:51:36 PM Operator: JB

COLOR: CMYK

TCP: 15001

Photometric Data

EVLP Low Profile
Hazard ȿ Gard®

Typedriver Name: TS name csm no.: 100

4L

Mogul Base

Mogul Base
Luminaire with Globe and 30° Angle Reflector (Less Guard)
EVLPA093170RA Lamp: 175W/ED28 Metal Halide (MH)

CANDELAS
Degrees
0
5
15
25
35
45
55
65
75
85
95
105
115
125
135
145
155
165
175
180

Front
Side
Back
3765
3765
3765
2986
2903
3379
2958
2301
2235
2678
2119
1744
2493
1859
1343
2736
1747
378
2804
1582
81
2729
871
3
2828
277
8
2378
63
16
2048
15
25
1010
10
24
274
10
139
75
11
18
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
ZONAL LUMENS
Zone
Lumens
0-10
285
10-20
689
20-30
1003
30-40
1229
40-50
1337
50-60
1232
60-70
1131
70-80
1035
80-90
659
90-100
228
100-110
109
110-120
26
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4L:791))
CH0 0 5 L 1 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

791

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0792-6 Name: 4L-792

4L

100:
DATE: JAN 19 2006

Time: 5:51:37 PM Operator: RB

EVM Hazard ȿ Gard®
H.I.D. Luminaires

COLOR: CMYK

TCP: 15001

ɀ

Cl. I, Div. 1 Groups B (GB suffix),C,D
Cl. I, Zone 1 Groups IIB + H2
(with suffix – GB), IIB IIA
ɀ Cl. II, Div. 1, Groups E,F,G; Class III,
Mogul Base
Simultaneous Presence (175W max)
Factory Sealed (Groups C.D)
ɀ

Typedriver Name: TS name csm no.: 100

ɀ

Paint Spray
(100W max)
ɀ Marine & Wet Locations
ɀ 3,3R,4,4X; IP66

Application:

Hazard ȿ Gard® luminaires are used in:
ɀ heavy process industries where flammable
or explosive vapors, gases or combustible
dusts are present
ɀ hazardous areas, both indoors and
outdoors where long life and low
maintenance costs are desired
ɀ petroleum refineries, chemical,
petrochemical and other heavy process
industry facilities
ɀ paint spray facilities
ɀ hazardous locations requiring elevated
ambient capability

Features:
ɀ Luminaire is factory wired; power is fed
through ‘‘wireless’’ connection block which
serves as a mechanical seal between conduit
and ballast compartments, eliminating the
need for an external, field installed seal. The
result is fast, easy installation.
ɀ Dome and 30° angle reflectors made of
Krydon® material – won’t rust, corrode, dent,
chip or peel (order separately – page 796).
ɀ High bay reflectors of Alzak® aluminum for
high wattage applications
ɀ Internally fluted glass globes reduce glare
and provide comfortable viewing light.
ɀ Wide range of light sources and wattages
to meet specific lighting needs – 50 – 400W
high pressure sodium (HPS); 100 – 400W
mercury vapor (MV); 70 – 400W metal halide
(MH).
ɀ High power factor (90% +) ballasts reduce
power costs – allow more luminaires per
circuit.
ɀ Four mounting arrangements to suit any
lighting layout – pendant, ceiling, wall bracket
and stanchion.
ɀ Paint spray booth suitability on 50 to 100
watt luminaires provides efficient, economical
H.I.D. lighting for areas where paint residue
may accumulate on luminaires.
ɀ Elevated ambient capability permits reliable
operation at high ambient temperature.
Selected luminaires are suitable for ambient
temperature up to 75°C.
ɀ Integral ballasts – separate ballasts are not
required. Lowest installed cost.
ɀ Factory sealed, porcelain, mogul base
socket.

Standard Materials:
ɀ Mounting modules, cover, ballast housing,
guard, globe ring – copper-free aluminum
ɀ Globe – heat and impact resistant glass
ɀ Exterior hardware – stainless steel
ɀ Lamp socket – porcelain with stainless steel
screw shell
ɀ Reflectors – dome and angle: Krydon
fiberglass-reinforced polyester material; high
bay: Alzak aluminum
Alzak is a registered trademark of ALCOA.
* IR and BG options cannot be used together.
** Can be used with BG option.
刁 CSA Certified luminaires are not available with multi-tap
ballast or S658 fuse option.
† When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

792

STIBOINFO((CRH:66008com:4L:792))
CH0 0 5 L 1 2

Standard Finishes:
ɀ Copper-free aluminum – epoxy powder
coat
ɀ Krydon – high reflectance white
ɀ Alzak – natural (anodized)

Options:
ɀ Fused – to protect ballast and capacitor
against abnormal line conditions. Add suffix
S658 to Cat. No.# †
ɀ Instant restrike – enables a hot HPS lamp to
immediately restrike after a momentary loss
of arc due to voltage fluctuation or power
outage. It has no effect on the warm-up
period of a cold lamp
(50-150W LX HPS only). Add suffix IR to Cat.
No.*
ɀ Quartz auxiliary lighting – quartz lamp
comes to full brightness instantly upon
restoration of power to provide emergency
illumination during the normal restrike period
of the H.I.D. lamp (for use with ED28 lamp).
Add suffix QTZ to Cat. No.** (Note: Quartz
lamp not included; use 100 W single-ended
lamp – Q100DC, Q100CL/DC, or
100Q/CL/DC.)
ɀ Ballast ȿ Gard – to eliminate the normally
continuous high voltage pulsing in the event
of a cycling lamp, inoperative lamp, or no
lamp in the socket extending the life of the
ballast.(For use with 50-400W HPS lamps.)
Add suffix BG to Cat. No.*
ɀ Group B suitability – luminaires suitable for
use in Class I, Group B hazardous (classified)
locations. Add suffix GB to Cat. No.

US: 1-866-764-5454

CAN: 1-800-265-0502

ɀ Hazard ȿ Gard® supplied with trunnion arm
for floodlighting applications. For use on
pendant mount luminaires only. Add suffix
S812 to Cat. No. – See Floodlight Section

Size Ranges:
ɀ 3⁄4⍯, 1⍯ and 11⁄4⍯ hubs (see ordering
information – pages 793 to 795)

Electrical Rating Ranges:

ɀ 120, 208, 240, 277, 347, 480, 600, multitap#.
ɀ 50 to 400 watts

Certifications and
Compliances:
ɀ NEC and CEC:
Class I, Division 1, Groups B (with suffix
GB), C,D
Class I, Zone 1, Groups IIB + H2 (with suffix
GB), IIB, IIA
100W max – Paint Spray Suitability
175W max – Class II, Class III, +
Simultaneous Presence
ɀ UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
ɀ CSA Standards:
C22.2 No. 137

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0793-2 Name: 4L-793

DATE: JAN 19 2006

50-400W EVM
Hazard ȿ Gard®H.I.D.
Luminaires

COLOR: CMYK

ɀ

Cl. I, Div. 1, Groups B(GB suffix),C,D
Cl. I, Zone 1 Groups IIB + H2
(with suffix GB), IIB, IIA
ɀ Cl. II, Div. 1, Groups E,F,G; Class III,
Simultaneous Presence (175W max)
ɀ

Mogul Base
Factory Sealed (Groups C,D)

Hub
Watts Size

Time: 5:51:38 PM Operator: RB

Pendant Luminaires
Without
With
Guard
Guard
Cat. #
Cat. #

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Paint Spray
(100W max)
ɀ Marine & Wet
Locations
ɀ 3,3R,4,4X; IP66

Wall Bracket Luminaires
Without
With
Guard
Guard
Cat. #
Cat. #

Ceiling Luminaires
Without
With
Guard
Guard
Cat. #
Cat. #

EVMBX42050
EVMBX43050

EVMCX42050 EVMCX42051
EVMCX43050 EVMCX43051

4L

Stanchion Luminaires (25°)
Without
With
Guard
Guard
Cat. #
Cat. #

High Pressure Sodium
50

3⁄4
1
11⁄4

EVMA42050
EVMA43050

70

3⁄4

EVMA42070
EVMA43070

1
11⁄4

EVMA42051
EVMA43051
EVMA42071
EVMA43071

EVMBX42070
EVMBX43070

EVMBX42051
EVMBX43051
EVMBX42071
EVMBX43071

3⁄4
1
11⁄4

EVMA42100
EVMA43100

EVMA42101
EVMA43101

EVMBX42100
EVMBX43100

EVMBX42101
EVMBX43101

EVMCX42100 EVMCX42101
EVMCX43100 EVMCX43101

150

3⁄4

EVMA42150
EVMA43150

EVMA42151
EVMA43151

EVMBX42150
EVMBX43150

EVMBX42151
EVMBX43151

EVMCX42150 EVMCX42151
EVMCX43150 EVMCX43151

200

3⁄4

1
11⁄4
250

3⁄4

1
11⁄4
400

3⁄4
1
11⁄4

EVMA42200
EVMA43200
EVMA42250
EVMA43250
EVMA42400
EVMA43400

EVMA42201
EVMA43201
EVMA42251
EVMA43251
EVMA42401
EVMA43401

EVMBX42200
EVMBX43200
EVMBX42250
EVMBX43250
EVMBX42400
EVMBX43400

EVMBX42201
EVMBX43201
EVMBX42251
EVMBX43251
EVMBX42401
EVMBX43401

EVMJ44051

EVMJ44070

EVMJ44071

EVMJ44100

EVMJ44101

EVMJ44150

EVMJ44151

EVMJ44200

EVMJ44201

EVMJ44250

EVMJ44251

EVMJ44400

EVMJ44401

EVMCX42070 EVMCX42071
EVMCX43070 EVMCX43071

100

1
11⁄4

EVMJ44050

EVMCX42200 EVMCX42201
EVMCX43200 EVMCX43201
EVMCX42250 EVMCX42251
EVMCX43250 EVMCX43251
EVMCX42400 EVMCX42401
EVMCX43400 EVMCX43401

Complete the Catalog Number by Adding Voltage and Options Suffixes as Follows:
1.

Standard Voltage Ballasts – 60HZ
NEC/UL
Voltage
Suffix

Multi-tap
/MT

120V
/120

480V
/480

Optional Voltage Ballasts – 50 or 60HZ
CEC/CSA (cUL)– CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

600V CWI
/600CWI

220V 60HZ
/220

CEC/CSA (cUL)
Tri-tap
/TT

120V
/120

Export
220V 50HZ
/220 50

230V 50HZ
/230 50

240V 50HZ
/240 50

2. 150W HPS Luminaires, 55V Lamps is Standard, for 100V lamps - Add suffix ‘‘CE’’
3. Options - Add the Required Options Suffixes from page 792, in Alpha-numeric Order

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4L:793))
CH0 0 5 L 1 3

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

793

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0794-3 Name: 4L-794

DATE: JAN 19 2006

Time: 5:51:40 PM Operator: JB

Factory Sealed (Groups C,D)

Hub
Watts Size

Pendant Luminaires
Without
With
Guard
Guard
Cat. #
Cat. #

TCP: 15001

ɀ

ɀ

ɀ

ɀ

Cl. I, Div. 1, Groups B (GB suffix),C,D
Cl. I, Zone 1 Groups IIB + H2
(with suffix GB), IIB, IIA
ɀ Cl. II, Div. 1, Groups E,F,G; Class III,
Simultaneous Presence (175W max)

70-400W EVM
Hazard ȿ Gard®
H.I.D Luminaires

4L

COLOR: CMYK

Wall Bracket Luminaires
Without
With
Guard
Guard
Cat. #
Cat. #

Ceiling Luminaires
Without
With
Guard
Guard
Cat. #
Cat. #
EVMCX92150-S828
EVMCX93150-S828

Typedriver Name: TS name csm no.: 100

Paint Spray (100W max)
Marine & Wet Locations
ɀ 3,3R,4,4X; IP66

Stanchion Luminaires (25°)
Without
With
Guard
Guard
Cat. #
Cat. #

Pulse Start Metal Halide
150

3⁄4
1
11⁄4

EVMA92150-S828
EVMA93150-S828

EVMA92151-S828
EVMA93151-S828

EVMBX92150-S828
EVMBX93150-S828

EVMBX92151-S828
EVMBX93151-S828

175

3⁄4

EVMA92170-S828
EVMA93170-S828

EVMA921701-S828
EVMA931701-S828

EVMBX92170-S828
EVMBX93170-S828

EVMBX921701-S828 EVMCX92170-S828
EVMBX931701-S828 EVMCX93170-S828

EVMCX921701-S828
EVMCX931701-S828

EVMA92200-S828
EVMA93200-S828

EVMA92201-S828
EVMA93201-S828

EVMBX92200-S828
EVMBX93200-S828

EVMBX92201-S828
EVMBX93201-S828

EVMCX92200-S828
EVMCX93200-S828

EVMCX92201-S828
EVMCX93201-S828

EVMA92250-S828
EVMA93250-S828

EVMA92251-S828
EVMA93251-S828

EVMBX92250-S828
EVMBX93250-S828

EVMBX92251-S828
EVMBX93251-S828

EVMCX92250-S828
EVMCX93250-S828

EVMCX92251-S828
EVMCX93251-S828

EVMA92320-S828
EVMA93320-S828

EVMA92321-S828
EVMA93321-S828

EVMBX92320-S828
EVMBX93320-S828

EVMBX92321-S828
EVMBX93321-S828

EVMCX92320-S828
EVMCX93320-S828

EVMCX92321-S828
EVMCX93321-S828

EVMA92400-S828
EVMA93400-S828

EVMA92401-S828
EVMA93401-S828

EVMBX92400-S828
EVMBX93400-S828

EVMBX92401-S828
EVMBX93401-S828

EVMCX92400-S828
EVMCX93400-S828

EVMCX92401-S828
EVMCX93401-S828

1
11⁄4
200

3⁄4

1
11⁄4
250

3⁄4

1
11⁄4
320

3⁄4

400

1
11⁄4
3⁄4
1
11⁄4

EVMCX92151-S828
EVMCX93151-S828
EVMJ94150-S828

EVMJ94151-S828

EVMJ94170-S828

EVMJ94171-S828

EVMJ94200-S828

EVMJ94201-S828

EVMJ94250-S828

EVMJ94251-S828

EVMJ94320-S828

EVMJ94321-S828

EVMJ94400-S828

EVMJ94401-S828

EVMJ94070

EVMJ94071

EVMJ94100

EVMJ94101

EVMJ94170

EVMJ94171

EVMJ94250

EVMJ94251

EVMJ94400

EVMJ94401

Metal Halide
70

100

175

250

400

3⁄4

1
11⁄4
3⁄4
1
11⁄4
3⁄4
1
11⁄4
3⁄4
1
11⁄4
3⁄4
1
11⁄4

EVMA92070
EVMA93070

EVMA92071
EVMA93071

EVMBX92070
EVMBX93070

EVMBX92071
EVMBX93071

EVMCX92070
EVMCX93070

EVMCX92071
EVMCX93071

EVMA92100
EVMA93100

EVMA92101
EVMA93101

EVMBX92100
EVMBX93100

EVMBX92101
EVMBX93101

EVMCX92100
EVMCX93100

EVMCX92101
EVMCX93101

EVMA92170
EVMA93170

EVMA92171
EVMA93171

EVMBX92170
EVMBX93170

EVMBX92171
EVMBX93171

EVMCX92170
EVMBX93170

EVMCX92171
EVMCX93171

EVMA92250
EVMA93250

EVMA92251
EVMA93251

EVMBX92250
EVMBX93250

EVMBX92251
EVMBX93251

EVMCX92250
EVMCX93250

EVMCX92251
EVMCX93251

EVMA92400
EVMA93400

EVMA92401
EVMA93401

EVMBX92400
EVMBX93400

EVMBX92401
EVMBX93401

EVMCX92400
EVMCX93400

EVMCX92401
EVMCX93401

Complete the Catalog Number by Adding Voltage and Options Suffixes as Follows:
1.

Standard Voltages Ballasts – 60HZ
NEC/UL
Voltage
Suffix

Multi-tap
/MT

Dual-Tap
/DT

120V
/120

480V
/480

CEC/CSA (cUL)
Tri-tap
/TT

Optional Voltage Ballasts – 50 or 60HZ
CEC/CSA (cUL)– CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

220V 60HZ
/220

Dual-Tap
/DT
Export

220V 50HZ
/220 50

230V 50HZ
/230 50

2. 150W HPS Luminaires, 55V Lamps is Standard, for 100V lamps - Add suffix ‘‘CE’’
3. Options - Add the Required Options Suffixes from page 792, In Alpha-numeric Order
* CWI Isolated Ballasts are only available for 175W–400W metal halide (non pulse start) luminaires.

794

STIBOINFO((CRH:66008com:4L:794))
CH0 0 4 L 1 4

US: 1-866-764-5454

CAN: 1-800-265-0502

120V
/120

Copyright© 2006 Cooper Crouse-Hinds

240V 50HZ
/240 50

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0795-2 Name: 4L-795

100:
DATE: JAN 19 2006

COLOR: CMYK

ɀ

ɀ

ɀ

ɀ

Cl. I, Div. 1, Groups B (GB suffix),C,D
Cl. I, Zone 1 Groups IIB + H2
(with suffix GB), IIB, IIA
ɀ Cl. II, Div. 1, Groups E,F,G; Class III,
Simultaneous Presence (175W max)

70-400W EVM
Hazard ȿ Gard®
H.I.D Luminaires
Factory Sealed (Groups C,D)

Hub
Watts Size

Time: 5:51:41 PM Operator: RB

Pendant Luminaires
Without
With
Guard
Guard
Cat. #
Cat. #

TCP: 15001

Typedriver Name: TS name csm no.: 100

Paint Spray (100W max)
Marine & Wet Locations
ɀ 3,3R,4,4X; IP66

Wall Bracket Luminaires
Without
With
Guard
Guard
Cat. #
Cat. #

Ceiling Luminaires
Without
With
Guard
Guard
Cat. #
Cat. #

4L

Stanchion Luminaires (25°)
Without
With
Guard
Guard
Cat. #
Cat. #

Mercury Vapor
100

175

250

400

3⁄4
1
11⁄4
3⁄4
1
11⁄4
3⁄4
1
11⁄4
3⁄4
1
11⁄4

EVMA82100
EVMA83100

EVMA82101
EVMA83101

EVMBX82100
EVMBX83100

EVMBX82101
EVMBX83101

EVMCX82100 EVMCX82101
EVMCX83100 EVMCX83101

EVMA82170
EVMA83170

EVMA82171
EVMA83171

EVMBX82170
EVMBX83170

EVMBX82171
EVMBX83171

EVMCX82170 EVMCX82171
EVMCX83170 EVMCX83171

EVMA82250
EVMA83250

EVMA82251
EVMA83251

EVMBX82250
EVMBX83250

EVMBX82251
EVMBX83251

EVMCX82250 EVMCX82251
EVMCX83250 EVMCX83251

EVMA82400
EVMA83400

EVMA82401
EVMA83401

EVMBX82400
EVMBX83400

EVMBX82401
EVMBX83401

EVMCX82400 EVMCX82401
EVMCX83400 EVMCX83401

EVMJ84100

EVMJ84101

EVMJ84170

EVMJ84171

EVMJ84250

EVMJ84251

EVMJ84400

EVMJ84401

Complete the Catalog Number by Adding Voltage and Options Suffixes as Follows:
1.

Standard Voltage Ballasts – 60HZ
NEC/UL
Voltage
Suffix

Multi-tap
/MT

Dual-Tap
/DT

120V
/120

480V
/480

Optional Voltage Ballasts – 50 or 60HZ
CEC/CSA (cUL)– CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

600V CWI
/600CWI

220V 60HZ
/220

CEC/CSA (cUL)
Tri-tap
/TT

Dual-Tap
/DT

120V
/120

Export
220V 50HZ
/220 50

230V 50HZ
/230 50

240V 50HZ
/240 50

2. Options - Add the Required Options Suffixes from page 792, in Alpha-numeric Order

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4L:795))
CH0 0 4 L 1 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

795

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0796-1 Name: 4L-796

4L

DATE: JAN 19 2006

Time: 5:51:43 PM Operator: JB

EVM Hazard ȿ Gard® H.I.D.
Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Accessories and
Temperature Performance Data

Reflectors

Dome

30° Angle

High Bay
Type

Cat. #

Dome
30° Angle
High Bay

RD739
RA739
EV3912

Temperature Performance Data
Maximum Ambient
Watts
40°C
55°C
High Pressure Sodium
50
T6
T6
70
T6
T6
100
T5
T5
150
T4A
T4A
200
T4A
T4A
250
T4
T3C
400
T3C
—
Mercury Vapor
100
T5
T5
175
T4A
T4
250
T3C
T3B
400
T3
—
Metal Halide (Including Pulse Start)
70
T6
T6
100
T5
T5
150
T4A
T4
175
T4A
T4
200
T4
T3C
250
T4
T3C
320
T3A
—
400
T3A
—

796

STIBOINFO((CRH:66008com:4L:796))
CH0 0 5 L 1 5

75°C

Class II
(E,F,G)
40°C

Simultaneous
Presence
40°C

Paint
Spray
Booth
40°C

Supply
Wire
°C

T6
T5
T4A
T4
T4
—
—

T5
T4A
T4A
—
—
—
—

T4
T4
T4
T3C
—
—
—

T4
T4
T4
T3C
—
—
—

T4A
T4A
T4A
—
—
—
—

90
90
90
90
90
90
90

T4A
T4
—
—

T4A
—
—
—

T3C
T3C
—
—

T3C
T3C
—
—

T4A
—
—
—

90
90
90
90

T5
T4A
T4
T4
—
—
—
—

T3
T3
—
—
—
—
—
—

T3C
T3C
T3C
T3C
—
—
—
—

T3C
T3C
T3C
T3C
—
—
—
—

T4A
T4A
—
—
—
—
—
—

90
90
90
90
90
90
90
90

Class I
65°C

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0797-1 Name: 4L-797

100:
DATE: JAN 19 2006

Time: 5:51:44 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

EVM Hazard ȿ Gard® H.I.D.
Luminaires

4L

Dimensions and Weights

Dimensions

Luminaire Net Weights:
H.I.D.
Source

High
Pressure
Sodium

Mercury
Vapor

Lamp
Watts
50
70
100
150 (55V)
150 (100V)
200
250
400

Luminaire Only
with Globe and
Guard (Lbs.)
40
40
44
45
44
46
46
55

100
175
250
400

38
41
43
49

70
39
100
39
175
42
250
43
400
51
Add for Mounting Modules:
Pendant 1 lb.
Bracket
Ceiling
2 lbs.
Stanchion
Metal
Halide

Deduct:
Guard

41⁄4 lbs.
21⁄4 lbs.

11⁄2 lbs.

Add for Reflectors:
RD739
13⁄4 lbs.
RA739
2 lbs.
EV3912
21⁄2 lbs.

Guard
EV503
EV5140

All luminaires with
100, 175, 250W MV
QTZ option and
50, 70, 100, 150W HPS 200, 250, 400W HPS
70, 100, 175, 250W MH 400W MV & MH
a
b
f
g
26
275⁄16
281⁄4
251⁄16
277⁄8
2813⁄16
301⁄8
311⁄16
24
2415⁄16
261⁄4
273⁄16
2211⁄16
241⁄8
251⁄4
261⁄8

Type
EVMA
EVMBX
EVMCX
EVMJ
‡ Suitable for Class III when listed for Class II, Group G.
ɍ See Options listing.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4L:797))
CH0 0 5 L 1 6

All – Reflectors
High
Dome –
Bay –
c
d
237⁄8
267⁄16
2611⁄16
293⁄4
2213⁄16
253⁄8
253⁄8
2711⁄16

CAN: 1-800-265-0502

30°
Angle –
e
289⁄16
313⁄8
271⁄2
283⁄4

Copyright© 2006 Cooper Crouse-Hinds

797

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

JOB: CRMAIN06-0798-2 Name: 4L-798

4L

100:
DATE: JAN 19 2006

Time: 5:51:45 PM Operator: RB

EVM Hazard ȿ Gard® H.I.D.
Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

Lamp: 100W/E-231⁄2 mercury vapor – (MV)
Total bare lamp lumens: 4200

Lamp: 100W/E231⁄2 mercury vapor – (MV)
Total bare lamp lumens: 4200

To determine number and placement of luminaires, see Lighting
Selector guide, pages 665 to 689

To determine number and placement of luminaires, see Lighting
Selector guide, pages 665 to 689

Luminaire With Globe and Without Guard

Luminaire With Globe, Dome Reflector and Without
Guard

NOTE: Photometric data was
developed using a 100 watt
diffuse mercury vapor lamp
(4,200 lumens). For other
diffuse lamps, use the following
conversion factors (multipliers):
175W MV – 2.05; 70W MH –
1.33; 100W MH – 1.85; 175W
MH (metal halide) – 3.33.
Multipliers are for use with
candela curve only.

NOTE: Photometric data was
developed using a 100 watt
diffuse mercury vapor lamp
(4,200 lumens). For other
diffuse lamps, use the following
conversion factors (multipliers):
175W MV – 2.05; 70W MH –
1.33; 100W MH – 1.85; 175W
MH (metal halide) – 3.33.
Multipliers are for use with
candela curve only.

Luminaire spacing ratio is 1.30.

Luminaire spacing ratio is 1.25.

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%

Effective Floor Cavity Reflectance 20%

% Reflectance
Eff. Ceil. Wall

Room Cavity Ratio
1
2
3

50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0
% Reflectance
Eff. Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

.694
.584
.503
.644
.516
.428
.600
.459
.369
.660
.556
.479
.615
.493
.410
.572
.441
.355
.596
.501
.432
.559
.450
.375
.526
.405
.328
.538
.451
.389
.509
.410
.342
.481
.373
.302
.485
.405
.349
.461
.371
.310
.439
.341
.277
.410
.313
.251
Room Cavity Ratio
6
7
8
.347
.312
.282
.273
.241
.214
.220
.192
.165
.331
.298
.270
.262
.231
.206
.211
.184
.160
.300
.272
.246
.241
.212
.190
.197
.171
.149
.272
.245
.225
.222
.196
.175
.183
.158
.139
.246
.224
.203
.202
.180
.160
.168
.147
.129
.148
.128
.111

798

STIBOINFO((CRH:66008com:4L:798))
CH0 0 5 L 1 9

98:

4

5

.439
.361
.302
.418
.347
.291
.377
.317
.270
.339
.290
.249
.305
.263
.228
.204

.386
.311
.253
.368
.297
.244
.334
.274
.227
.302
.250
.210
.271
.223
.193
.171

9
.259
.192
.147
.248
.185
.143
.227
.172
.134
.207
.158
.124
.188
.146
.115
.099

10
.230
.166
.125
.220
.162
.121
.203
.150
.113
.185
.138
.105
.169
.127
.096
.082

US: 1-866-764-5454

CAN: 1-800-265-0502

% Reflectance
Eff. Ceil. Wall

Room Cavity Ratio
1
2
3

50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0
% Reflectance
Eff. Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

.715
.637
.570
.688
.596
.521
.665
.562
.483
.699
.624
.560
.675
.586
.514
.652
.556
.478
.668
.598
.539
.648
.568
.500
.631
.540
.468
.640
.576
.519
.624
.550
.487
.609
.527
.459
.615
.554
.502
.602
.533
.474
.589
.514
.450
.575
.500
.436
Room Cavity Ratio
6
7
8
.414
.375
.340
.358
.319
.286
.318
.282
.247
.407
.369
.335
.354
.315
.283
.315
.278
.246
.394
.358
.325
.347
.309
.278
.312
.275
.244
.383
.346
.316
.340
.304
.273
.308
.272
.242
.371
.338
.307
.333
.299
.268
.304
.269
.240
.292
.257
.227

Copyright© 2006 Cooper Crouse-Hinds

4

5

.509
.455
.413
.500
.450
.410
.481
.438
.404
.465
.428
.398
.450
.418
.391
.377

.458
.401
.359
.448
.396
.356
.434
.388
.353
.420
.379
.348
.407
.372
.343
.329

9
.313
.259
.222
.308
.256
.221
.299
.252
.219
.292
.248
.217
.284
.244
.215
.204

10
.275
.222
.187
.271
.222
.187
.264
.217
.185
.257
.214
.183
.251
.210
.181
.170

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0799-2 Name: 4L-799

100:
DATE: JAN 19 2006

EVM Hazard ȿ Gard® H.I.D.
Luminaires

Time: 5:51:46 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

Isofootcandle Chart: Luminaire With Globe and 30°
Angle Reflector, Without Guard

4L

Lamp: 150W/E-231⁄2 high pressure sodium (HPS)
Total bare lamp lumens: 16,000
To determine number and placement of luminaires, see Lighting
Selector Guide, pages 665 to 689.

Luminaire With Globe and Without Guard
NOTE: Photometric data was
developed using a 150 watt
clear high pressure sodium
lamp (16,000 lumens). For
other clear lamps, use the
following conversion factors
(multipliers): 50W HPS – .25;
70W HPS – .40; 100W HPS –
.59. Multipliers are for use
with candela curve only.
Luminaire spacing ratio is
0.80.

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
Lamp: 100W/E-231⁄2 diffuse mercury vapor (MV)
Total bare lamp lumens: 4200
To determine number and placement of luminaires, see Lighting
Selector Guide, pages 665 to 689.
Illumination in footcandles on work plane 10 feet below light center.
Multiply by factor shown to convert to other mounting heights.
Height (Ft.)
6
7
8

Factor
2.78
2.04
1.56

Height (Ft.)
9
11
12

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4L:799))
CH0 0 5 L 2 0

Factor
1.23
0.83
0.70

CAN: 1-800-265-0502

% Reflectance
Eff. Ceil. Wall

Room Cavity Ratio
1
2
3

50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0
% Reflectance
Eff. Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

.695
.579
.494
.644
.509
.417
.599
.450
.356
.659
.549
.469
.613
.484
.397
.570
.431
.341
.592
.491
.419
.555
.439
.360
.522
.393
.312
.531
.438
.373
.502
.396
.325
.474
.358
.284
.476
.390
.331
.451
.355
.291
.429
.325
.257
.399
.295
.230
Room Cavity Ratio
6
7
8
.342
.306
.278
.266
.234
.209
.212
.184
.160
.324
.292
.265
.254
.223
.201
.202
.176
.155
.292
.263
.240
.232
.203
.184
.187
.162
.143
.262
.236
.218
.211
.186
.167
.172
.148
.132
.234
.213
.195
.190
.169
.152
.156
.135
.121
.135
.116
.103

Copyright© 2006 Cooper Crouse-Hinds

4

5

.410
.326
.262
.387
.311
.251
.344
.279
.229
.304
.250
.207
.267
.222
.184
.159

.382
.305
.246
.363
.291
.236
.327
.265
.218
.292
.240
.200
.260
.217
.181
.159

9
.265
.198
.153
.253
.191
.149
.231
.177
.139
.210
.162
.129
.191
.149
.118
.103

10
.233
.168
.127
.222
.163
.123
.203
.150
.114
.185
.138
.105
.167
.125
.096
.081

799

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

JOB: CRMAIN06-0800-2 Name: 4L-800

4L

100:
DATE: JAN 19 2006

Time: 5:52:44 PM Operator: RB

EVM Hazard ȿ Gard® H.I.D.
Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

Lamp: 150W/E-231⁄2 high pressure sodium (HPS)
Total bare lamp lumens: 16000

Total bare lamp lumens: 16000

To determine number and placement of luminaires, see Lighting
Selector Guide, pages 665 to 689.

To determine number and placement of luminaires, see Lighting
Selector Guide, pages 665 to 689.

Luminaire With Globe, Hi-Bay Reflector and Without
Guard

Luminaire With Globe, Dome Reflector and Without
Guard

Lamp: 150W/E-231⁄2 high pressure sodium (HPS)

NOTE: Photometric data was
developed using a 150 watt
clear high pressure sodium
lamp (16,000 lumens). For
other clear lamps, use the
following conversion factors
(multipliers): 50W HPS – .25;
70W HPS – .40; 100W HPS –
.59. Multipliers are for use with
candela curve only.

NOTE: Photometric data was
developed using a 150 watt
clear high pressure sodium
lamp (16,000 lumens). For
other clear lamps, use the
following conversion factors
(multipliers): 50W HPS – .25;
70W HPS – .40; 100W HPS –
.59. Multipliers are for use with
candela curve only.

Luminaire spacing ratio is 1.00.

Luminaire spacing ratio is 1.20.

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%

Effective Floor Cavity Reflectance 20%

% Reflectance
Eff. Ceil. Wall

Room Cavity Ratio
1
2
3

50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0
% Reflectance
Eff. Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

.668
.618
.573
.651
.592
.542
.636
.569
.517
.655
.608
.566
.639
.583
.536
.625
.564
.513
.629
.587
.550
.616
.568
.525
.606
.550
.505
.606
.569
.535
.597
.554
.514
.588
.539
.497
.586
.553
.522
.578
.539
.504
.570
.528
.489
.560
.517
.479
Room Cavity Ratio
6
7
8
.460
.427
.396
.420
.388
.358
.394
.361
.330
.455
.423
.392
.418
.385
.356
.391
.359
.329
.444
.414
.385
.412
.380
.352
.388
.357
.328
.436
.406
.379
.407
.377
.348
.385
.354
.326
.428
.400
.373
.402
.373
.345
.382
.352
.324
.373
.343
.315

800

STIBOINFO((CRH:66008com:4L:800))
CH0 5 L - 2 1

98:

4

5

.531
.495
.468
.525
.491
.464
.511
.482
.459
.498
.474
.454
.487
.466
.449
.439

.494
.455
.427
.487
.452
.425
.476
.446
.422
.466
.438
.418
.457
.433
.413
.404

9
.369
.330
.303
.366
.328
.303
.360
.325
.301
.354
.322
.300
.348
.319
.298
.290

10
.328
.288
.262
.325
.288
.262
.320
.285
.261
.315
.282
.259
.311
.280
.258
.249

US: 1-866-764-5454

CAN: 1-800-265-0502

% Reflectance
Eff. Ceil. Wall

Room Cavity Ratio
1
2
3

50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0
% Reflectance
Eff. Ceil. Wall
50
80
30
10
50
70
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

.716
.637
.568
.689
.596
.519
.666
.561
.480
.700
.624
.559
.675
.585
.512
.653
.555
.476
.668
.598
.538
.648
.567
.498
.631
.539
.466
.640
.575
.518
.625
.549
.485
.610
.526
.457
.615
.554
.500
.602
.532
.472
.590
.513
.448
.575
.498
.434
Room Cavity Ratio
6
7
8
.413
.373
.339
.355
.318
.285
.316
.280
.246
.405
.368
.334
.352
.314
.283
.312
.277
.245
.392
.356
.324
.345
.307
.277
.309
.274
.243
.380
.345
.316
.338
.303
.272
.306
.270
.241
.369
.337
.307
.331
.298
.267
.301
.267
.238
.289
.255
.226

Copyright© 2006 Cooper Crouse-Hinds

4

5

.507
.452
.410
.498
.447
.407
.479
.435
.400
.463
.425
.394
.447
.415
.388
.373

.455
.398
.355
.446
.393
.353
.432
.385
.349
.417
.376
.344
.404
.369
.339
.326

9
.312
.258
.221
.308
.256
.221
.299
.252
.219
.291
.247
.217
.283
.244
.215
.203

10
.275
.222
.187
.271
.222
.187
.264
.217
.185
.257
.214
.183
.251
.210
.181
.170

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0801-7 Name: 5L-801

100:
DATE: JAN 19 2006

Time: 5:52:45 PM Operator: RB

COLOR: CMYK

TCP: 15001

Luminaires with Induction Lighting System

Typedriver Name: TS name csm no.: 100

5L

Hazardous and Non-Hazardous

Description

Page No.

VMVIG Series
DMVIG Series

802–808
802–808

Note: Induction Lighting is also available with our Champ-Pak TM Wall Pack Luminares.
Please see page 867 in Section 7L for more details.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:5L:801))
CH0 0 5 L 2 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

801

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0802-17 Name: 5L-802

5L

100:
DATE: JAN 19 2006

Time: 5:52:46 PM Operator: RB

Luminaires with Induction
Lighting System
VMVIG and DMVIG Series

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Class I, Division 2, Groups A,B,C,D
Class I, Zone 2, Group IIC
Resricted Breathing Suffix S826 for CI.I, Div 2 & Zone 2
Enclosure Type 4X, IP66 ɀ Marine Locations
Wet Locations ɀ UL and cUL Listed

Get uninterrupted light for up to 11 years,
without changing a lamp.
Cooper Crouse-Hinds® Champ Luminaire with Induction Light Source
delivers up to 100,000 hours of white light in a hazardous location,
corrosion-resistant watertight package. That’s 5 to 8 times the typical
life of conventional fluorescent or HID lamps. And, with no
maintenance required for up to 11 years, you’ll reduce your
maintenance and lamp replacement costs.
Compelling reasons to choose the new Champ Induction
luminaire as the light source for industrial and hazardous
locations include:
ɀ Crisp white light (80+ color rendering index) provides
increased safety by clearly illuminating signs, instrument
panels, equipment and more with vibrant natural colors.
ɀ Up to 100,000 hours of lamp life minimizes routine
maintenance costs. If you operate this luminaire for 24
hours, 7 days a week, you will not need to change the lamp
for up to 11 years!
ɀ Instant illumination — no waiting for lamp warm-up time.
Increases productivity and safety.
ɀ Delivers the best possible luminaire temperature rating —
T6 (85°C) when used with the Champ restricted breathing
option. Ideal for hazardous areas where a low ignition
temperature is required.
ɀ Starts in low temperatures — as low as -40°C.

165W Champ Induction provides as much light as a 175W Metal
Halide but lasts 7 times longer!

ADDITIONAL FEATURES & BENEFITS:
The Champ Induction luminaire is suitable for Class I, Division 2 and
Zone 2 areas with the assurance of Cooper Crouse-Hinds quality and
reliability. They are ideal for use in hard-to-reach applications and
where process requirements demand continuous luminaire operation.

Features:
ɀ High lumens per watts (72 lpw for the 165W Champ) will save energy
ɀ Retains strong light output (retains more than 70% output)
throughout the life of the lamp
ɀ Will not add electrical noise to the circuits — Total Harmonic
Distortion is less than 10%
ɀ Excellent power factor of .96 increases useable watts to an excellent
level and reduces energy consumption
ɀ Internal electronics are enclosed to ensure that there is no
interference with external instrumentation

802

STIBOINFO((CRH:66008com:5L:802))
CH0 5 L - 2 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0803-21 Name: 5L-803

100:
DATE: JAN 19 2006

Luminaires with Induction
Lighting System
VMVIG and DMVIG Series

Time: 5:52:48 PM Operator: RB

TCP: 15001

Typedriver Name: TS name csm no.: 100

Class I, Division 2, Groups A,B,C,D
Class I, Zone 2, Group IIC
Resricted Breathing Suffix S826 for CI.I, Div 2 & Zone 2
Enclosure Type 4X, IP66 ɀ Marine Locations
Wet Locations ɀ UL and cUL Listed

5L

APPLICATIONS:

STANDARD FINISHES:

Champ Induction luminaires are ideal:
ɀ Where an extra long life lamp source (up to 100,000 hrs) is required.
ɀ In areas that require lamps to reach full illumination immediately.
ɀ Where cool temperature ratings on the luminaire globe are needed
to ensure safe operation in hazardous areas.
ɀ In hard-to-reach applications where relamping is costly.
ɀ Where luminaire maintenance is difficult due to continuous
process operation requirements that restrict or prohibit shut down
except in emergency situations.
ɀ To provide a cost-effective lighting system (low installed/life cost) by
minimizing or even eliminating routine luminaire maintenance.
ɀ In cold environment applications.

ɀ Copper-free aluminum — epoxy powder coat
ɀ Krydon® material — high reflectance white
ɀ Stainless steel — natural

CERTIFICATIONS AND COMPLIANCES:
NEC & CEC:
ɀ Class I, Division 2 and Zone 2
ɀ Class I, Division 2 Groups A, B, C, D
Class I, Zone 2 Group IIC
ɀ Restricted Breathing Suffix S826 for Class I, Division 2 & Zone 2
ɀ Marine Locations, Wet Locations, Enclosure Type 3, 3R, 4, 4X; IP66
ɀ UL and cUL Listed
UL Standards: 844, 60079-15, 1598, 1598A
CSA Standards: C22.2 No.137, E79 Series
Compliances and aprovals for the lamp system
ɀ RFI < 30 MHz
ɀ RFI > 30 MHz
ɀ Harmonics
ɀ Immunity
ɀ Safety
ɀ Performance
ɀ Vibration & bump tests
ɀ Quality standards
ɀ Environmental standard

EN 55015
EN 55022
EN 61000-3-2
EN 61547
EN 61347-2-3 & UL935
EN 60928
EN 60929
IEC 68-2-6-Fc
IEC 68-2-29-Eb
ISO 9001
ISO 14001

STANDARD MATERIALS:
ɀ Ballast housings and mountings — copper-free aluminum (less than
0.4 of 1%)
ɀ Exterior hardware — stainless steel
ɀ Reflectors (dome and angle) — Krydon fiberglass-reinforced
polyester material
ɀ Globes — heat and impact-resistant internally fluted glass
ɀ Guards — copper-free aluminum (55W), stainless steel (85W).

US: 1-866-764-5454

STIBOINFO((CRH:66008com:5L:803))
CH0 0 5 L 2 0

COLOR: CMYK

CAN: 1-800-265-0502

OPTIONS:
DESCRIPTION
Restricted Breathing Construction
Class I, Division 2 & Zone 2 suitability
Cooler operating temperatures (T-Codes)

SUFFIX TO ADD
TO CATALOG NO.

S826

ACCESSORIES:
MOUNTING MODULES
3⁄4 NPT Pendant
1 NPT Pendant
3⁄4 NPT Flexible Pendant
3⁄4 NPT Ceiling Mount
1 NPT Ceiling Mount
3⁄4 NPT Wall Mount
1 NPT Wall Mount
3⁄4 NPT Quad Mount
1 1⁄2 NPT Stanchion Mount — 25 Degree Angle
1 1⁄2 NPT Stanchion Mount — Straight
WATTAGE
55W
85W
165W

DOME REFLECTOR
CATALOG NO.
RD70
RD739
RD739

CAT. NO.
APM2
APM3
HPM2
CM2
CM3
TWM2
TWM3
QM25
JM5
PM5
ANGLE REFLECTORS
CATALOG NO.
RA70
RA739
RA739

DIMENSIONS:
See Catalog 6000 Section 3L for dimensional information on VMV and
DMV Series

AMPERAGE:
Power consumption for specific voltages as follows:
55W LUMINAIRES
a. 120VAC x .460mA ⍧ 55.70 watts
b. 230VAC x .260mA ⍧ 59.80 watts
85W LUMINAIRES
c. 120VAC x .710mA ⍧ 85.20 watts
d. 230VAC x .400mA ⍧ 92.00 watts
165W LUMINAIRES
e. 230VAC x .700mA ⍧ 161.00 watts

Copyright© 2006 Cooper Crouse-Hinds

803

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0804-30 Name: 5L-804

5L

DATE: JAN 19 2006

Time: 5:52:48 PM Operator: RB

Luminaires with Induction
Lighting System
VMVIG and DMVIG Series

COLOR: CMYK

VMV
DMV
DMV

LUMEN (LM)
INITIAL
MEAN
3500
2800
6000
4800
12000
9600

Typedriver Name: TS name csm no.: 100

Class I, Division 2, Groups A,B,C,D
Class I, Zone 2, Group IIC
Restricted Breathing Suffix S826 for CI.I, Div 2 & Zone 2
Enclosure Type 4X, IP66 ɀ Marine Locations
Wet Locations ɀ UL and cUL Listed

LAMP DATA:
SYSTEM
Power (W)
55
85
165

TCP: 15001

COLOR
RENDERING
INDEX*
80
80
80

EFFICACY (LM/W)
INITIAL
MEAN
65
51
70
57
72
58

LUMEN
MAINTENANCE
AFTER 60,000 HRS (%)
75
75
70

* Lamp sources with 80+ CRI provide excellent color rendering. CRI scale is 0-100 with 100 considered as ideal.

TEMPERATURE PERFORMANCE DATA:

CATALOG #
VMVIG055
VMVIG055
DMVIG085
DMVIG085
DMVIG165

WATTS
55
55
85
85
165

AMBIENT
TEMP °C
40
55
40
55
40

SUPPLY WIRE
TEMP °C
60
75
60
75
75

CLASS I, DIV. 2
TEMP. RATING
T2C
T2C
T2D
T2D
T3

CLASS II, DIV. 1,
CLASS III
TEMP. RATING
–
–
T2D
–
–

SIMULTANEOUS
PRESENCE
CLASS I, DIV. 2
–
–
T2D
–
–

RESTRICTED BREATHING
(SUFFIX S826)
Aex nR IIC, Ex nR IIC
CLASS I, DIV. 2/Zone 2
T6
T5
T6
T6
T5

Champ Induction DMV 85-watt is now Class II Div.1 – suitable for dust environments

ORDERING INFORMATION:
To complete Catalog Number, add Voltage and Option suffix(es).

MOUNTING STYLE
Pendant
Flexible Pendant
Ceiling Mount
Wall Mount
Quad Mount
Stanchion Mount 25° Angle
Stanchion Mount Straight
Luminaire with Globe and Guard
less Mounting Module
Standard Voltage
120V, 50/60 Hz
200V-277V, 50/60 Hz

HUB SIZE
(INCHES)
3⁄4
1
3⁄4
3⁄4
1
3⁄4
1
3⁄4
1 1⁄2
1 1⁄2

55W INDUCTION
CATALOG NUMBER
(WITH G24 GLOBE
& P21 GUARD)
VMVIG2A055GP
VMVIG3A055GP
VMVIG2HA055GP
VMVIG2C055GP
VMVIG3C055GP
VMVIG2TW055GP
VMVIG3TW055GP
VMVIG25Q055GP
VMVIGJ055GP
VMVIG2P055GP

85W INDUCTION
CATALOG NUMBER
(WITH G303 GLOBE
& P33 GUARD)
DMVIG2A085GP
DMVIG3A085GP
DMVIG2HA085GP
DMVIG2C085GP
DMVIG3C085GP
DMVIG2TW085GP
DMVIG3TW085GP
DMVIG25Q085GP
DMVIGJ085GP
DMVIG2P085GP

165W INDUCTION
CATALOG NUMBER
(WITH G303 GLOBE
& P33 GUARD)
*DMVIG2A165GP
*DMVIG3A165GP
*DMVIG2HA165GP
*DMVIG2C165GP
*DMVIG3C165GP
*DMVIG2TW165GP
*DMVIG3TW165GP
*DMVIG25Q165GP
*DMVIGJ165GP
*DMVIG2P165GP

—

VMVIG055GP

DMVIG085GP

*DMVIG165GP

Suffix
/120
/200 277

Operative range of 108-132 VAC
Operates on 208, 220, 230, 240, 277 VAC

Add the voltage suffix to the
above catalog number.
Ex. - DMVIG2A085GP/120

* 165W Champ Induction Luminaires are only available in 200-277VAC

804

STIBOINFO((CRH:66008com:5L:804))
CH0 5 L - 2 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0805-17 Name: 5L-805

100:
DATE: JAN 19 2006

Time: 5:52:49 PM Operator: JB

COLOR: CMYK

TCP: 15001

Photometric Data

Luminaires with Induction
Lighting System

Typedriver Name: TS name csm no.: 100

5L

VMVIG and DMVIG Series

55 WATT INDUCTION

LUMINAIRE WITH GLOBE AND GUARD
VMVIG055GP LAMP: 55W INDUCTION

85 WATT INDUCTION

LUMINAIRE WITH GLOBE AND GUARD
DMVIG085GP LAMP: 85W INDUCTION

Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our Luxicon
Lighting Layout Software are available to download

US: 1-866-764-5454

STIBOINFO((CRH:66008com:5L:805))
CH0 0 5 L 2 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

805

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0806-9 Name: 5L-806

5L

100:
DATE: JAN 19 2006

Time: 5:52:52 PM Operator: JB

Luminaires with Induction
Lighting System

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

VMVIG and DMVIG Series

165 WATT INDUCTION

LUMINAIRE WITH GLOBE
DMVIG165G LAMP: 165W INDUCTION

165 WATT INDUCTION

LUMINAIRE WITH GLOBE AND GUARD
DMVIG165GP LAMP: 165W INDUCTION

Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our Luxicon
Lighting Layout Software are available to download

806

STIBOINFO((CRH:66008com:5L:806))
CH0 5 L - 2 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0807-9 Name: 5L-807

100:
DATE: JAN 19 2006

Time: 5:52:54 PM Operator: JB

COLOR: CMYK

TCP: 15001

Photometric Data

Luminaires with Induction
Lighting System

Typedriver Name: TS name csm no.: 100

5L

VMVIG and DMVIG Series

165 WATT INDUCTION

LUMINAIRE WITH GLOBE AND RD739 DOME REFLECTOR
DMVIG165G LAMP: 165W INDUCTION

165 WATT INDUCTION

LUMINAIRE WITH GLOBE AND RA739 (30° ANGLE) REFLECTOR
DMVIG165G LAMP: 165W INDUCTION

Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our Luxicon
Lighting Layout Software are available to download

US: 1-866-764-5454

STIBOINFO((CRH:66008com:5L:807))
CH0 0 5 L 2 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

807

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0808-7 Name: 5L-808

5L

100:
DATE: JAN 19 2006

Time: 5:52:56 PM Operator: JB

Luminaires with Induction
Lighting System

COLOR: CMYK

TCP: 15001

Family Tree

VMVIG and DMVIG Series

808

STIBOINFO((CRH:66008com:5L:808))
CH0 5 L - 2 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0809-5 Name: 6L-809

100:
DATE: JAN 19 2006

Time: 5:52:57 PM Operator: JB

COLOR: CMYK

TCP: 15001

Fluorescent Luminaires
Hazardous and Non-Hazardous

Typedriver Name: TS name csm no.: 100

6L

Description

Page No.

Application/Selection

810

General Purpose Luminaires
VF Vaporgard TM Series

811-813

Non-Metallic Luminaires
NFL Series
N2MVF

843-845
823-828

Hazardous Area Luminaires
CPMVF
DMVF
eLLB20 Series
eLLK Series
EVLPF
EVF Series
EVFDR Series
EVFT Illuminator TM Series
FVN Series
FVS Series
nLLK Series

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:809))
CH0 0 0 0 5 L

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

814, 815
816-822
855-857
846-848
829-835
858-861
862, 863
839-842
852-854
836-838
849-851

809

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0810-9 Name: 6L-810

100:
DATE: JAN 19 2006

Time: 5:52:57 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Fluorescent Lighting Luminaires

6L

Hazardous and Non-Hazardous
Application and Selection
Quick Selector Chart
Application:
ɀ for use in hazardous or non-hazardous
areas (as shown in the Quick Selector Chart
below)
ɀ low operating cost
ɀ high light output per watt
ɀ low brightness
ɀ low glare
ɀ uniform light
ɀ instant illumination

Considerations for
Selection:

Table 500-3(d)
Identification Numbers.

Having made the determination that a
fluorescent luminaire is required, the
remaining selection is the type of luminaire
(i.e., number and kind of lamps) and
placement of luminaire. To determine the
number of luminaires:
1. Determine Cavity Ratios for room, ceiling
and floor.
2. Determine Coefficient of Utilization
3. Determine Light Loss
4. Determine Lamp Lumens required =
Footcandles x Area
Coefficient of Utilization x Light Loss Factor
5. Determine number of luminaires required =
Total Lamp Lumens Required
Lamp Lumens per Luminaire
A more complete explanation of the steps to
be followed can be found in the Lighting
Selector Guide, pages 665 through 689.

Maximum
Temperature
Deg. C
Deg. F
450
842
300
572
280
536
260
500
230
446
215
419
200
392
180
356
165
329
160
320
135
275
120
248
100
212
85
185

Quick Selector Chart
Series

NEC – Hazardous
Area Compliance

Lamp
Watts

Volts

No. of
Lamps

VF

Cl. I, Division 2, Groups A,B,C,D

NFL

Cl. I, Division 2, Groups A,B,C,D

5, 7, 9

120

2

32, 40

120-277V 50-60Hz

1, 2

FVN

Cl. I, Division 2, Groups A,B,C,D;
Cl. II, Groups F,G;
Cl. III

32, 40, 60

120, 277, 220/240 50 or 60 Hz

2, 3

EVF

Cl. I, Groups C,D;
Cl. II, Groups E,F,G

32, 40, 60, 110

120, 277, 347, 220/240 50 or 60
Hz

1, 2, 3, 4

EVFDR

Cl. I, Groups C,D;
Cl. II, Groups E,F,G

32, 40, 60, 110

120, 277, 220/240 50 or 60 Hz

2

EVFT

Cl. I, Groups B,C,D;
Cl. II, Groups E,F,G;
Cl. III

39

120, 277, 220/240 50 or 60 Hz

2, 4

FVS

Cl. I, Division 2, Groups B,C,D;
Cl. II, Groups E,F,G;
Cl. III

40

120-277V, 50-60Hz or
347V, 60Hz

2

DMVF

Cl. I, Division 2, Groups A,B,C,D;
Cl. II, Groups E,F,G;
Cl. III; Simultaneous Presence

26, 32

120-277V, 50-60Hz or
347V, 60Hz

2, 3

N2MVF

Cl. I, Div. 2, Groups A,B,C,D
Class II, Groups F,G
Class III; Simultaneous Presence

26, 32

120-277V, 50-60Hz or
347V, 60Hz

2

EVLP

Cl. I, Div.1, Groups (B), C, D
Cl. II, Groups E, F, G
Cl. III; Simultaneous Presence

26, 32

120-277V, 50-60Hz or
347V, 60Hz

2

CPMVF

Cl. I, Div. 2, Groups A, B, C, D

26, 32, 42

120-277V, 50-60Hz,
347V 60Hz

2

eLLB 20

Cl. I, Division 2, Groups A,B,C,D;
Cl. I, Zone 1, Group IIC;
Cl. II, Division 2, Groups F,G

17, 32

120-240V, 50-60Hz
110-230 VDC

2

ELLK

Cl. I, Zone I & Div 2
Cl. II, Div 2

32

120-254V

2

nLLK

Cl. I, Division 2, Groups A,B,C,D;
Cl. I, Zone 2 AEx nA II;
Cl. II, Division 2, Groups F,G

17, 32

120-277V, 60Hz

2

810

STIBOINFO((CRH:66008com:6L:810))
CH0 0 5 L - 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Identification
Number
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0811-4 Name: 6L-811

100:
DATE: JAN 19 2006

Time: 5:52:58 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. I, Div. 2, Groups A,B,C,D*
Cl. I, Zone 2 IIC*
ɀ Wet Locations
ɀ NEMA 3,3R

VF Series Vaporgard TM
Fluorescent Luminaires

6L

ɀ

Application:

Accessories:

VF series Vaporgard fluorescent lighting
luminaires are used:
ɀ indoors or outdoors in industrial locations
where enclosed and gasketed luminaires are
required
ɀ where the energy efficiency and long life of
single twin-tube compact fluorescent lamps
are desired
ɀ where luminaires may be subject to wet,
damp, dirty locations
ɀ where vibration and rough usage are a
problem
ɀ to retrofit existing Vaporgard incandescent
luminaires
ɀ in tunnels, building entrances, utility rooms,
hallways and similar locations
ɀ with clear or colored globes to illuminate or
mark critical locations or processes

ɀ See page 812 for complete listing

Luminaire Net Weights:
1-Lamp
2-Lamp
Luminaire
Luminaire
Fixture
With Globe &
With Globe &
Type
Guard (lbs.)
Guard (lbs.)
5
VFA
43⁄4
VFHF
5
51⁄4
VFHBF
71⁄4
71⁄2
Add for Reflectors (lbs.):
Dome
1
30° Angle
1
1⁄2
Deduct (lbs.): P21 Guard

Temperature Performance
Data:

Features:
ɀ Compact size and light weight allow
adaptation and easy installation in many
industrial applications
ɀ Cast copper-free aluminum (less than 0.4 of
1% copper) construction and epoxy powder
finish provide excellent resistance to
corrosion
ɀ Variety of mounting arrangements to suit
any lighting layout – pendant, ceiling, wall
bracket, angle stanchion, through feed, box
mount
ɀ VFH luminaire components can be installed
on existing Vaporgard incandescent
components and standard stamped metal
boxes
ɀ Fixtures available for use with two compact
fluorescent lamps. Lamps rated at 5, 7 or 9
watts can be used with all luminaires
ɀ Dome and 30° angle reflectors made of
bright white Krydon® material provide
superior reflectivity. Will not chip, peel, dent,
rust or corrode. (Order separately – see page
812)
ɀ Glass globes are internally fluted and
stippled to reduce glare and provide even
light distribution. Exteriors are smooth to
shed dust
ɀ All luminaires 120 VAC only!
ɀ Grounding wire for safety

Certifications and
Compliances:

Class I
Lamp Div. 2
5, 7W T3B
9W
T3B

Max.
Ambient
40°C
40°C

Supply
Wire °C
75°C
75°C

Minimum
Operating
–18°C (0°F)
–4°C (25°F)

ɀ UL Standard: 1598, 844
ɀ CSA Standard C22.2 No. 137

Dimensions

VFHA
VFC

VFH

Standard Materials:
ɀ Bodies and guards – copper-free aluminum
(less than 0.4 of 1%)
ɀ Globes – clear or colored, glass or plastic
ɀ Reflectors – Krydon fiberglass-reinforced
polyester material

VFHF

VFHBF

VFHT

VFA

Standard Finishes:
ɀ Copper-free aluminum – powder epoxy
finish
ɀ Krydon material – high reflectance white

Electrical Ratings:
ɀ Input voltage – 120 VAC, 60 hertz
ɀ Wattages: two 5, 7 or 9 watt lamps

* All mountings except stanchion.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:811))
CH0 0 5 L - 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

811

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0812-3 Name: 6L-812

100:
DATE: JAN 19 2006

Time: 5:52:59 PM Operator: TB

VF Series Vaporgard TM
Fluorescent Luminaires

6L

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. I, Div. 2, Groups A,B,C,D**
Cl. I, Zone 2 IIC**
ɀ Wet Locations
ɀ NEMA 3,3R
ɀ

Twin-Tube Fluorescent with G24 Clear Glass Globe and P21 Guard (lamps not included)

Luminaire
Watts

Hub
Size
1⁄2
2 Lamps, 18 3⁄4
1
watts max.
11⁄4

Pendant
Mount
Cat. #
VFA122GP
VFA222GP
VFA322GP

Ceiling
Mount
Cat. #
VFHF122GP
VFHF222GP

Wall
Mount
(w/Box)
Cat. #
VFHBF122GP
VFHBF222GP

Wall
Mount
(No Box)
Cat. #
VFHT122GP
VFHT222GP

Angle
Stanchion
Mount*
Cat. #

Through
Feed
Mount
Cat. #
VFC122GP
VFC222GP

Box
Mount &
Retrofit
Cat. #
VFH122GP

VFHA422GP*

VF Series with Colored Glass Globes or Plastic Globes.
To obtain:
ɀ Substitute appropriate globe designation for ‘‘G’’ in above Cat. Nos.
ɀ Refer to section 1L for globe designations.

Accessories and Components
Reflectors

Globes

Guard
For use with
glass globes only

Dome
Cat. # RD71
(Cannot be used with wall
mount luminaires)

30°Angle
Cat. # RA71

Color
Clear
Green
Blue
Red
Amber

Glass
Cat. #
G24
G25
G26
G27
G28

Plastic
Cat. *
G63
G65
G67

Cat. #
P21

Junction Boxes and Bracket Bodies

VXF – 4 Hubs, 3 Plugs
Hub Size
1⁄2
3⁄4

Cat. #
VXF10
VXF20

VXFT– 5 Hubs, 4 Plugs
Hub Size
1⁄2
3⁄4

Cat. #
VXFT10
VXFT20

* For non-hazardous locations.
 – available with Lightning Service TMdelivery
See Section G for complete details

812

STIBOINFO((CRH:66008com:6L:812))
CH0 0 5 L - 2

VXT – 3 Hubs, 2 Plugs
Hub Size
1⁄2
3⁄4

Cat. #
VXT10
VXT20

VXA – Stanchion Mount (Non Hazardous Locations)
Hub Size
11⁄4

Cat. #
VXA4

VXB – 3 Hubs, 2 Plugs
Hub Size
1⁄2
3⁄4

Cat. #
VXB10 (Includes adapter plate and two gaskets for mounting to VXF, GRF or 4⍯ outlet boxes)
VXB11 (Includes 1 gasket for mounting to VXF or GRF junction boxes.)

** All mountings except stanchion.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0813-2 Name: 6L-813

100:
DATE: JAN 19 2006

Time: 5:53:02 PM Operator: TB

COLOR: CMYK

TCP: 15001

Family Tree

Vaporgard TM Series
Fluorescent Luminaires

Typedriver Name: TS name csm no.: 100

6L

 – available with Lightning Service TM delivery. See Section G for complete details.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:813))
CH0 0 5 L - 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

813

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0814-5 Name: 6L-814

6L

100:
DATE: JAN 19 2006

Time: 5:53:03 PM Operator: TB

CPMVF Champ-Pak TM
Compact Fluorescent
Luminaires

COLOR: CMYK

ɀ

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2*
(Suffix S826)
ɀ Certified for IEC Zone 2*
(Suffix S826TB)
ɀ

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III &
Simultaneous Presence*
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP56

Application:
CPMVF Champ-Pak TM luminaires are used:
ɀ Indoor and outdoor wall mounting or vertical surface mounting
where minimal luminaire depth is required in:
– Manufacturing plants and heavy industrial facilities
– Industrial process facilities such as refineries, chemical,
petrochemical, pharmaceutical and platforms
– Waste or sewage treatments plants
– Offshore, dockside and harbor installations
ɀ For security and safety lighting in industrial facilities
for lighting of loading docks, tunnels and stairways
ɀ For marine, wet location, hosedown and corrosive environments

Features & Benefits:
ɀ Unique compact shallow-profile design mounts virtually anywhere
ɀ Side hinged cover with two screw closing for easy installation and
maintenance
ɀ Gray Corro-free TM epoxy powder coat two-piece housing provides
superior corrosion resistance
ɀ Unique stainless steel wire guard accessory attaches without any
additional hardware for easy installation and maintenance
ɀ Glass refractor provides uniform light distribution to eliminate glare
ɀ Silicon gaskets make luminaire suitable for NEMA 4X, Marine
environments
ɀ High power factor ballasts (+90%) are standard, which allow more
luminaires per circuit

Standard Materials:
ɀ Luminaire housing and door frame assembly – copper-free
aluminum
ɀ External hardware – stainless steel
ɀ Lens – heat and impact-resistant refractor style glass
ɀ Gaskets – silicon rubber
ɀ Reflector – aluminum light sheet
ɀ Wire guard – stainless steel

Standard Finishes:
ɀ Aluminum – Corro-free TM epoxy powder coat
ɀ Stainless steel – natural

Certificates and Compliances:
ɀ NEC and CEC:
- Class I, Division 2, Groups A, B, C, D
- Class II, Class III &
Simultaneous Presence (Class 1,
Division 2 and Class II)*
- Class I Zone 2
ɀ IEC:
- Zone 2 Ex nR IIC
ɀ UL Standards:
- 844, 2279 Hazardous (Classified)
Locations
- 1598 Luminaires
- 1598A Marine Locations
ɀ CSA Standards
- C22.2 No. 137
ɀ IEC Standards
- 60079-15

Electrical Rating Ranges:
ɀ Wattages: Two 26, 32, or 42 watt lamps.
ɀ 120-277V, 50-60Hz
ɀ 347V, 60Hz
ɀ 12, 24 & 125VDC (Consult Cooper Crouse-Hinds)

Options:
Suffix to add
to Cat. No. #

ɀ Restricted Breathing Construction
- Class I Division 2 & Zone 2 Suitability . . . . . . . . . . . . . . . . . . . S826*
- Cooler Operating Temperatures (T-Numbers)
ɀ Certified for IEC Zone 2 (Suffix S826TB). . . . . . . . . . . . . . . . . S826TB*
(Guard Required)
- Furnished with
- Terminal Block
- Crimp Terminals
ɀ Factory Assembled with Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FA
ɀ Fused - protects ballast and capacitors. . . . . . . . . . . . . . . . . . . . S658†
against abnormal line conditions
(Not for use in Canada)
(Not for Marine use)

Accessories:
Photocell for Field Installation
ɀ 120V, 50/60Hz
ɀ 208-240V, 50/60Hz
ɀ 277V, 50/60Hz
Stainless Steel Wire Guard

ɀ Less wattage used with compact fluorescent lamps compared to
equivalent incandescent lamps providing the same light output.

* Contact Cooper Crouse-Hinds

STIBOINFO((CRH:66008com:6L:814))
CH0 5 L - 1 4

US: 1-866-764-5454

V2PC20
V2PC22
V2PC27
P55

† When ordering Fuses for luminaires, option S658, you must specify the operating voltage.
S658 can not be ordered with /MT in the catalog number.

Energy Savings:

814

Cat. #

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0815-3 Name: 6L-815

DATE: JAN 19 2006

Time: 5:53:04 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Ordering Information
Temperature Performance Data
Dimensions & Weights

CPMVF Champ-Pak TM
Compact Fluorescent
Luminaires

6L

Ordering Information:
Hub Size
3⁄4 NPT
3⁄4 NPT
3⁄4 NPT

Luminaire
Watts
52
64
84

Catalog Number
CPMVF2W052
CPMVF2W064
CPMVF2W084

STANDARD VOLTAGE BALLASTS

OPTIONAL BALLASTS

NEC/UL & CEC/CSA (cUL)

CEC/CSA (cUL)

120-277V 50-60Hz
/UNV

347V 60Hz
/347

Voltage
Suffix

(Consult Cooper Crouse-Hinds)
125V DC
/125VDC

12V DC
/012VDC

24V DC
/024VDC

CPMVF Temperature Performance Data – Consult Cooper Crouse-Hinds

Dimensions (Inches)

Net Weight:
CPMVF Less Guard
P55 Guard

17 Lbs
0.5 Lbs

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:815))
CH0 0 3 L - 4

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

815

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0816-5 Name: 6L-816

6L

100:
DATE: JAN 19 2006

Time: 5:53:05 PM Operator: JB

DMVF Series
Compact Fluorescent
Champ® Luminaires

COLOR: CMYK

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

Application:

Energy Savings

DMVF series Champ luminaires are used:
ɀ in areas made hazardous by abnormal
conditions resulting in the presence of
flammable vapors or gases.
ɀ in areas made hazardous by the presence
of combustible dusts.
ɀ where combustible dusts and flammable
vapors are present simultaneously.
ɀ in marine applications where water spray
and corrosive atmospheres are
considerations.
ɀ on installations where vibration and rough
usage are problems.
ɀ where a cool, efficient light source is
required.
ɀ in areas that require lamps to reach full
illumination immediately.
ɀ in refineries, chemical and petrochemical
facilities, grain processing, handling or
storage facilities, manufacturing plants waste
water treatment plants sewage treatment
plants, oil terminals, food processing
facilities, breweries, and any other
manufacturing or processing facility where
safe, reliable, hazardous area fluorescent or
auxiliary lighting is needed.

ɀ Less wattage used with compact
fluorescent lamps compared to equivalent
incandescent lamps providing the same light
output.

Standard Features:
ɀ Housings made of die-cast copper-free
aluminum (less than 0.4 of 1% copper) for
strength and resistance to corrosion.
ɀ Mounting modules equipped with integral
hub set screws for vibration resistance
(ceiling, pendant, and quad mounts).
ɀ Hubs are provided with an integral conduit
stop and bushing to help prevent damage to
field wiring during installation.
ɀ Epoxy powder finish and stainless steel
external hardware for resistance to corrosion.
ɀ Long-life gaskets which provide seals
between mounting module, housing, and
optical assembly.
ɀ Grounding wire for safety.
ɀ Cool operating design.
ɀ Optional stainless steel open bottom guard
permits direct access to the globe for easy
relamping.
ɀ Optional battery pack ballast for auxiliary
lighting.

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III &
Simultaneous Presence
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66

Standard Materials:
ɀ Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%).
ɀ Exterior hardware and guards – stainless
steel.
ɀ Reflectors – Krydon® fiberglass-reinforced
polyester material.
ɀ Globe – heat and impact resistant internally
fluted glass.

Standard Finishes:
ɀ Aluminum – gray epoxy powder coat.
ɀ Krydon material – high reflectance white.
ɀ Stainless steel – natural.

Electrical Rating Ranges:
ɀ Wattage: Two 26 or 32 watt lamps
ɀ 120-277V, 50-60 Hz
ɀ 347V, 60Hz
ɀ 12, 24, & 125VDC

Certificates and
Compliances:
ɀ NEC and CEC:
Class I, Division 2, Groups A, B, C, D
Class II, Class III &
Simultaneous Presence (Class 1,
Division 2 and Class II)
Class I Zone 2
ɀ IEC:
Zone 2 Ex nR IIC
ɀ UL Standards:
844, 2279 Hazardous (Classified)
Locations
1598 Luminaires
1598A Marine Locations
ɀ CSA Standards
C22.2 No. 137
ɀ IEC Standards
60079-15

Accessories:
(Order separately)
ɀ Reflectors (to be used with globe)
Dome Cat. # RD739
30° Angle Cat. # RA739

Options:
Description

Suffix to add
to Cat. No. #

ɀ Restricted Breathing Construction
Class I Division 2 & Zone 2 Suitability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S826
Cooler Operating Temperatures (T-Numbers)
ɀ Certified for IEC Zone 2 (Suffix S826TB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S826TB
Furnished with
Terminal Block
Crimp Terminals
ɀ Factory Assembled with lamps installed for additional labor savings. . . . . . . . . . . . . . . . . . . . FA.
ɀ Fused – to protect ballast against abnormal line conditions (not available on
CSA certified fixtures) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S658*.
ɀ Lamps supplied with fixture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S714.
ɀ Top hat with stainless steel threaded insert to attach ballast housing . . . . . . . . . . . . . . . . . S806.
ɀ TEFLON® coating on globe for increased shatter protection . . . . . . . . . . . . . . . . . . . . . . . . . S808.
* When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT
in the catalog number.

816

STIBOINFO((CRH:66008com:6L:816))
CH0 0 5 L - 8

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0817-4 Name: 6L-817

DATE: JAN 19 2006

DMVF Series
Compact Fluorescent
Champ® Luminaires

Time: 5:54:07 PM Operator: GK COLOR: CMYK

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

Mounting
Style
Pendant Mount

Hub
Size
3⁄4
1
3⁄4
1

Luminaire
Watts
52
64

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III &
Simultaneous Presence
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66

6L

DMVF Series
Fluorescent
Cat. No. with G303
Globe and P33
Guard
DMVF2A052GP
DMVF3A052GP
DMVF2A064GP
DMVF3A064GP

Flexible Pendant
Mount

3⁄4
3⁄4

52
64

DMVF2HA052GP
DMVF2HA064GP

Ceiling Mount
Thru-Feed

3⁄4

52

1
3⁄4
1

64

DMVF2C052GP
DMVF3C052GP
DMVF2C064GP
DMVF3C064GP

3⁄4

52

1
3⁄4
1

64

Wall Mount
Thru-Feed

TCP: 15001

DMVF2TW052GP
DMVF3TW052GP
DMVF2TW064GP
DMVF3TW064GP

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
121⁄2° Angle

3⁄4
3⁄4

52
64

DMVF25Q052GP
DMVF25Q064GP

Stanchion Mount
25° Angle

11⁄2
11⁄2

52
64

DMVFJ052GP
DMVFJ064GP

Stanchion Mount
Straight

11⁄2
11⁄2

52
64

DMVFP052GP
DMVFP064GP

1. Catalog numbers are basic numbers. Voltages must be specified.

Voltage
Suffix

STANDARD VOLTAGE BALLASTS
NEC/UL & CEC/CSA (cUL)
120-277V 50-60Hz
/UNV

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:817))
CH0 0 5 L - 9

CAN: 1-800-265-0502

OPTIONAL BALLASTS
CEC/CSA (cUL)
347V 60Hz
/347

125V DC
/125VDC

Copyright© 2006 Cooper Crouse-Hinds

12V DC
/012VDC

24V DC
/024VDC

817

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0818-2 Name: 6L-818

6L

100:
DATE: JAN 19 2006

Time: 5:54:12 PM Operator: TB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

DMVF Series Ordering by Components

DMVF luminaires are available in components
A complete luminaire consists of:
I.
Champ Cover (Mounting Module)
II.
DMVF Ballast Housing
III.
Globe, Globe Guard, Globe Reflectors

I. Champ Cover (Mounting Module):
Type
Pendant
Flexible Pendant
Ceiling
Wall
Stanchion - 25 Degree Angle
Stanchion - Straight
Quad-Mount

Conduit
3⁄4

1
3⁄4
3⁄4
1
3⁄4
1
11⁄2
11⁄2
3⁄4

Cat. No.
APM2
APM3
HPM2
CM2
CM3
TWM2
TWM3
JM5
PM5
QM25

II. Ballast Housings. Complete catalog number must have the voltage suffix (UNV shown) and any options suffixes.
Lamp Type
Compact Fluorescent

Lamp
Watts
2 (26W)
2 (32W)

Catalog Number
DMVF052/UNV
DMVF064/UNV

III. Globe, Guards and Reflectors
Type
Globe
Teflon Coated
Globe Guard
Globe Reflector-Dome
Globe Reflector-Angle

818

STIBOINFO((CRH:66008com:6L:818))
CH0 3 L - 1 5

Catalog Number
G303
G303-S808
P33
RD739
RA739

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0819-2 Name: 6L-819

100:
DATE: JAN 19 2006

Time: 5:54:13 PM Operator: TB

COLOR: CMYK

TCP: 15001

Family Tree

DMVF Series
Compact Fluorescent

Typedriver Name: TS name csm no.: 100

6L

Champ® Luminaires

* These plastic reflectors are for non-hazardous areas only (50-100W max.)
 – available with Lightning Service TM delivery. See Section G for complete details.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:819))
CH0 3 L - 1 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

819

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0820-2 Name: 6L-820

6L

DATE: JAN 19 2006

Time: 5:54:14 PM Operator: TB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Temperature Performance Data
Weights

DMVF Series
Compact Fluorescent
Champ® Luminaires

Temperature Performance Data:
Lamp
Watts
Fluorescent:

Minimum
Operating
Temperature
DMVF

52 & 64 Watt

-20°C (4°F)

Class I
Non-Restricted Restricted
Breathing
Breathing
Div. 2
Zone 2 or
Div. 2
40°C (104°F)
T3
T6
Maximum
Ambient
Temp

Class II
Division 1
T6

Simultaneous Presence
Non-Restricted
Restricted
Breathing
Breathing
Cl.I, Div. 2/Cl.II
Cl.I, Zone 2 or
Div. 2/Cl.II
T3/T6
T6

Net Luminaire Weights (lbs.)
Luminaire
Luminaire
Lamp
with Globe,
Series
Watts
Guard (lbs.)
DMVF
52, 64
181⁄4
Add for mounting modules (lbs.):
Pendant
11⁄4
Flexible Pendant
11⁄2
Ceiling
23⁄4
Wall
41⁄2
Quad-Mount
31⁄2
Angle Stanchion
31⁄2
Straight Stanchion
41⁄2
Add for reflectors (lbs.):
Dome
11⁄4
30° Angle
13⁄4
Deduct: 1 lb. for luminaire with P33 Guard

820

STIBOINFO((CRH:66008com:6L:820))
CH0 5 L - 1 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Supply
Wire °C

60

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0821-2 Name: 6L-821

DATE: JAN 19 2006

Time: 5:54:15 PM Operator: TB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

DMVF Series
Compact Fluorescent

6L

Champ® Luminaires

NOTE: For 52 watt DMVF applications, use a .75 multiplier.

DMVF064GRD Dome Reflector
Coefficients of Utilization
Effective Floor Cavity Reflectance 20%

DMVF Photometric Data
ISOFOOTCANDLE CHART:
Luminaire with globe and dome reflector
DMVF064GRD Dome Reflector

Room Cavity Ratio
Eff.
Ceil.
80*

70*

50*

Wall

1

2

3

4

5

6

7

8

9

10

50*
30*
10*
50*
30*
10*

.741
.694
.652
.722
.679
.640

.617
.548
.491
.601
.537
.483

.524
.445
.382
.510
.437
.378

.452
.370
.308
.440
.364
.305

.396
.314
.254
.386
.309
.252

.351
.271
.214
.342
.267
.212

.314
.237
.183
.307
.234
.182

.283
.210
.159
.277
.207
.158

.258
.188
.140
.252
.185
.139

.236
.169
.125
.231
.167
.124

50*
30*
10*

.686
.650
.617

.570
.516
.470

.484
.421
.369

.418
.351
.299

.367
.299
.247

.326
.259
.209

.293
.227
.180

.265
.202
.155

.242
.181
.138

.223
.163
.123

.542
.497
.457
.516
.478
.444
.424

.460
.406
.361
.437
.392
.352
.332

.398
.340
.293
.379
.329
.287
.267

.350
.290
.243
.333
.271
.239
.220

.311
.251
.206
.297
.244
.203
.184

.280
.221
.177
.268
.215
.175
.157

.254
.197
.154
.244
.192
.152
.136

.233
.176
.136
.224
.172
.135
.119

.214
.160
.121
.206
.156
.120
.105

50*
.653
30*
.623
10*
.596
.50* .622
10*
30*
.598
10*
.576
0*
0*
.557
* Percent Reflectance
30*

Footcandle Values for Isofootcandle Lines
MTG.
HGT.
8′
10′
12′
16′

A
4.00
2.56
1.78
1.00

B
2.00
1.28
0.89
0.50

C
1.00
0.64
0.44
0.25

D
0.50
0.32
0.22
0.13

E
0.25
0.16
0.11
0.06

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:821))
CH0 5 L - 1 2

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

821

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0822-2 Name: 6L-822

DATE: JAN 19 2006

Time: 5:54:16 PM Operator: TB

TCP: 15001

Dimensions

DMVF Series
Compact Fluorescent

6L

COLOR: CMYK

Champ® Luminaires

DMVF Dimensions
Pendant Mount

Quad-Mount

25° Angle Stanchion Mount

Ceiling Mount

Ceiling Mount – Top View

Straight Stanchion Mount

822

STIBOINFO((CRH:66008com:6L:822))
CH0 5 L - 1 3

Luminaire with Globe, Guard, Reflectors

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0823-2 Name: 6L-823

100:
DATE: JAN 19 2006

N2MVF Series
Compact Fluorescent
Champ® Non-metallic
Luminaires

Time: 5:54:19 PM Operator: TB

ɀ

Cl. I, Div. 2, Groups A,B,C,D
Restricted Breathing Cl. I,
Div. 2 & Zone 2
(Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

Additional Features:
FLUORESCENT ENERGY SAVINGS
ɀ Less wattage used with compact
fluorescent lamps compared to equivalent
incandescent lamps providing the same light
output.

6L

Certifications and
Compliances:
ɀ NEC and CEC:
Class I, Division 2, Groups A,B,C,D
Class II, Class III &
Simultaneous Presence (Class I Division 2
and II)
Class I Zone 2
ɀ IEC:
Zone 2 Ex nR IIC
ɀ UL Standards:
844. 2279 Hazardous (Classified)
Locations
1598 Luminaires
1598A Marine Locations
ɀ CSA Standards:
C22.2 No. 137
ɀ IEC Standards:
60079-15

Standard Materials:
ɀ Housing, mounting modules –
polyphenylene sulfide (PPS)
ɀ Guard, hub inserts, stanchion elbow,
hardware – stainless steel
ɀ Globe – heat & impact resistant, internally
fluted glass
ɀ Gaskets – silicone rubber

Electrical Ratings:
ɀ Wattages: Two 26 or 32 watt lamps.
ɀ 120 – 277V, 50-60 Hz
ɀ 347V, 60 Hz
ɀ 12, 24 & 125 VDC

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:823))

Typedriver Name: TS name csm no.: 100

Cl. II Groups F,G, Cl. III &
Simultaneous Presence
ɀ Marine & Wet Locations
ɀ 3,3R, 4,4X; IP56

N2MVF series Champ luminaires are used:
ɀ in areas in which ignitable concentrations of
flammable gases or vapors will be present
due to abnormal, unusual or accidental
conditions.
ɀ in installations where moisture, dirt,
vibration, corrosion or rough usage are
concerns.
ɀ wherever the damaging effects of water,
wind, snow, sleet, hot sun or any
combination of these elements are found.
ɀ ideal for marine use; resists the harmful
effects of salt water.
ɀ withstands the harshest of corrosive
environments.
ɀ to provide low wattage spot and
floodlighting.
ɀ for general area lighting.
ɀ in manufacturing plants, refineries,
chemical, petrochemical and other industrial
process facilities, wastewater and sewage
treatment facilities, offshore, dockside and
harbor installations as well as other heavy
industrial applications.
ɀ Housings and mounting modules made of
polyphenylene sulfide (PPS) for strength and
maximum resistance to corrosion.
ɀ Pendant mounting module equipped with
integral hub set screws for vibration
resistance.
ɀ Hubs are provided with an integral bushing
to help prevent damage to field wiring during
installation and ground connection for
positive bonding.
ɀ Guard, hub inserts, stanchion elbow and
hardware made of stainless steel for
maximum resistance to corrosion.
ɀ Grounding wire for safety.
ɀ Stainless steel open bottom guard permits
direct access to the globe for easy relamping.
ɀ Hinged assembly allows the luminaire to
hang free during installation to permit the use
of both hands when wiring.
ɀ One, external captive screw for ease of
installation.
ɀ Handle – hinge assembly doubles as a
handle for ease of installation, especially
when carrying up a ladder.

TCP: 15001

ɀ

Application:

Features and Benefits:

CH0 5 L - 1 4

COLOR: CMYK

Options:
Description

Suffix to be
added to Cat. No.
ɀ Restricted Breathing Construction
S826
Class I Division 2 & Zone 2 Suitability
Cooler Operating Temperatures
(T-Numbers)
ɀ Certified for IEC Zone 2
S826TB
Furnished with
Terminal Block
Crimp Terminals
Wall-Mount Arm
For converting a ceiling-mount luminaire to a
wall mount
N2MV-WM1
Factory Assembled
For a factory assembled luminaire with lamps
installed
FA
Fusing
To protect ballast against abnormal line
conditions
S658
Furnished with Lamps
S714
Teflon Coated Globe
Provides additional protection against
shattered glass fragments when subject to
thermal shock, etc.
S808

Average Luminaire Weight
(lbs.)
Body, mounting module, globe, guard and
reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 lbs.

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

823

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0824-2 Name: 6L-824

100:
DATE: JAN 19 2006

Time: 5:54:19 PM Operator: TB

N2MVF Series
Compact Fluorescent

6L

Champ® Non-metallic
Luminaires

COLOR: CMYK

ɀ

Cl. I, Div. 2, Groups A,B,C,D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups F,G, Cl. III &
Simultaneous Presence
ɀ Marine & Wet Locations
ɀ 3,3R, 4,4X; IP56

N2MVF ORDERING INFORMATION
Mounting
Style
Pendant Mount

Ceiling Mount ThruFeed

Stanchion Mount
25° Angle

Hub
Size
3⁄4
1
3⁄4
1
3⁄4
1
3⁄4
1
11⁄2
11⁄2

Lamp
Watts
52
64
52
64
52
64

With G303 Globe
and P33 Guard
Cat. No.†
N2MVF2A052GP
N2MVF3A052GP
N2MVF2A064GP
N2MVF3A064GP
N2MVF2C052GP
N2MVF3C052GP
N2MVF2C064GP
N2MVF3C064GP
N2MVFJ052GP
N2MVFJ064GP

STANDARD VOLTAGE BALLASTS
Voltage
Suffix

NEC/UL & CEC/CSA (cUL)
120-277V 50-60Hz
/UNV

OPTIONAL BALLASTS
CEC/CSA (cUL)
347V 60Hz
/347

125V DC
/125VDC

12V DC
/012VDC

24V DC
/024VDC

Temperature Performance Data:
Lamp
Watts
Fluorescent:
52 & 64 Watt

824

STIBOINFO((CRH:66008com:6L:824))
CH0 5 L - 1 5

Class I
Minimum
Maximum
Operating
Ambient
Non-Restricted Restricted
Temperature
Temp
Breathing
Breathing
N2MVF
Division 2
Zone 2
-18°C (0°F) 40°C (104°F)
T2D
T6

US: 1-866-764-5454

CAN: 1-800-265-0502

Class II
Division 1
T4

F & G Simultaneous Presence
Non-Restricted
Restricted
Breathing
Breathing
Cl.I, Div 2/Cl.II Cl.I, Zone 2/Cl.II
T2B/T4
T4

Copyright© 2006 Cooper Crouse-Hinds

Supply
Wire °C
85

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0825-3 Name: 6L-825

100:
DATE: JAN 19 2006

Time: 5:54:20 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

N2MVF SeriesOrdering by Components

6L

N2MVF luminaires are available in components
A complete luminaire consists of:
I.
N2MV Cover (Mounting Module)
II.
N2MV Ballast Housing
III.
Globe, Refractors, Guards, Reflectors

I. N2MV Cover (Mounting Module):
Type
Pendant
Ceiling
Wall (Use wall bracket
accessory with Ceiling Cover)
Stanchion - 25 Degree Angle

Conduit
3⁄4

1
3⁄4
1
3⁄4
1
11⁄2

Cat. No.
N2APM2
N2APM3
N2CM2
N2CM3
N2MV-WM1 and N2CM2
N2MV-WM1 and N2CM3
N2JM5

II. Ballast Housings. Complete catalog number must have the voltage suffix (UNV shown) and any options suffixes.
Lamp Type
Compact Fluorescent

Lamp
Watts
2 (26W)
2 (32W)

Catalog Number
N2MVF052/UNV
N2MVF064/UNV

III. Globe, Guard and Reflectors
Type
Globe
Globe Teflon Coated
Globe Guard
Reflector Dome
Reflector Angle

Catalog Number
G303
G303-S808
P33
RD739
RA740

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:825))
CH0 3 L - 1 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

825

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0826-2 Name: 6L-826

6L

100:
DATE: JAN 19 2006

Time: 5:54:21 PM Operator: TB

N2MVF Series
Compact Fluorescent

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Family Tree

Champ® Non-metallic Luminaires

A complete luminaire consists of a cover mount, a ballast housing and a globe,
with or without guard, refractor or reflector.

ALL COMPONENTS ARE SUITABLE FOR
USE IN ORDINARY LOCATIONS, CLASS 1,
DIV.2 AND WET LOCATIONS.

826

STIBOINFO((CRH:66008com:6L:826))
CH0 3 L - 3 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0827-3 Name: 6L-827

DATE: JAN 19 2006

Time: 5:54:22 PM Operator: TB

N2MVF Series
Compact Fluorescent

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

6L

Dimensions
Weights

Champ® Non-Metallic Luminaires

Pendant Mount

Ceiling Mount – Top View

Ceiling Mount

25° Angle Stanchion Mount

Wall Arm Mount

Net Luminaire Weights (lbs.)

Luminaire
Series

Lamp
Watts

Luminaire with
Mounting Module,
Globe, Guard &
Refractor
(lbs.)

N2MVF052
N2MVF064

52
64

30
30

Accessories (Order Separately)
Reflectors (to be used with globe)
Dome Cat.
RD739 (RD79)
30° Angle Cat.
RA739 (RA79)

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:827))
CH0 5 L - 1 8

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

827

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0828-3 Name: 6L-828

6L

100:
DATE: JAN 19 2006

Time: 5:54:23 PM Operator: TB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

N2MVF Series
Compact Fluorescent
Champ® Non-Metallic Luminaires

Photometric Data

NOTE: For 52 watt N2MVF applications, use a .75 multiplier.

N2MVF Photometric Data
ISOFOOTCANDLE CHART:
Luminaire with globe and dome reflector
N2MVF064GRD Dome Reflector

Footcandle Values for Isofootcandle Lines
MTG.
HGT. A
B
C
D
E
8′
4.00
2.00
1.00
0.50
0.25
10′
2.56
1.28
0.64
0.32
0.16
12′
1.78
0.89
0.44
0.22
0.11
16′
1.00
0.50
0.25
0.13
0.06

828

STIBOINFO((CRH:66008com:6L:828))
CH0 5 L - 1 6

US: 1-866-764-5454

N2MVF064GRD Dome Reflector
Coefficients of Utilization
Effective Floor Cavity Reflectance 20%
Room Cavity Ratio
Eff.
Ceil. Wall 1
2
3
4
5
6

7

8

9

10

80*

50*
30*
10*

.741
.694
.652

.617
.548
.491

.524
.445
.382

.452
.370
.308

.396
.314
.254

.351
.271
.214

.314
.237
.183

.283
.210
.159

.258
.188
.140

.236
.169
.125

70*

50*
30*
10*

.722
.679
.640

.601
.537
.483

.510
.437
.378

.440
.364
.305

.386
.309
.252

.342
.267
.212

.307
.234
.182

.277
.207
.158

.252
.185
.139

.231
.167
.124

.570
.516
.470
.542
.497
.457
.516
.478
.444
.424

.484
.421
.369
.460
.406
.361
.437
.392
.352
.332

.418
.351
.299
.398
.340
.293
.379
.329
.287
.267

.367
.299
.247
.350
.290
.243
.333
.271
.239
.220

.326
.259
.209
.311
.251
.206
.297
.244
.203
.184

.293
.227
.180
.280
.221
.177
.268
.215
.175
.157

.265
.202
.155
.254
.197
.154
.244
.192
.152
.136

.242
.181
.138
.233
.176
.136
.224
.172
.135
.119

.223
.163
.123
.214
.160
.121
.206
.156
.120
.105

50*
.686
30*
.650
10*
.617
50*
.653
30*
30*
.623
10*
.596
50*
.622
10*
30*
.598
10*
.576
0*
0*
.557
* Percent Reflectance
50*

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0829-4 Name: 6L-829

100:
DATE: JAN 19 2006

EVLPF Series
Compact Fluorescent
Low Profile Hazard ȿ Gard®
Luminaires

Time: 5:54:23 PM Operator: JB

COLOR: CMYK

ɀ

Cl. I, Div. 1, Groups B (GB Suffix),C,D
Cl. I, Zone 1, Groups IIB + H2
(GB Suffix), IIB, IIA
ɀ Cl. II, Div 1, Groups E, F, G; Class III,
Simultaneous Presence
ɀ

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Marine & Wet
Locations
ɀ 3,3R,4,4X; IP66

6L

Application:
Cooper Crouse-Hinds Low Profile
Hazard ȿ Gard® luminaires are used in:
ɀ areas where flammable or explosive vapors
or gases are present
ɀ hazardous areas, both indoors and
outdoors, where long life and low
maintenance costs are desired
ɀ petroleum refineries, chemical,
petrochemical and pharmaceutical plants, oil
terminals, gas plants and other heavy
process industry facilities
ɀ waste treatment facilities
ɀ drilling platforms and other coastal and
offshore hazardous areas

Features - Benefits:
ɀ Small compact size
ɀ Two start Acme threaded construction
ɀ Light weight copper-free aluminum housing
with powdered epoxy finish
ɀ All exterior hardware is corrosion-resistant
stainless steel
ɀ Four mounting arrangements pendant,
ceiling, wall bracket and stanchion
ɀ Wide range of light sources and wattages
ɀ Marine and Nema 4X construction
ɀ Integral ballast
ɀ High power factor (90%+) ballasts
ɀ Uses same mounting modules as the
standard Hazard ȿ Gard®
ɀ Internally fluted glass globes
ɀ Krydon® construction dome and angle
reflectors – won’t rust, corrode, dent, chip or
peel
ɀ Now available in components – luminaire
body, mounting module, guard, reflectors
ɀ Three wire construction is standard on
Fluorescent Emergency Lighting
ɀ Perfect where low mounting restrictions are
a concern
ɀ Easier assembly, installation and
maintenance
ɀ Superior corrosion resistance
ɀ Suit any lighting layout
ɀ Meet specific lighting needs
ɀ Outdoor, hose down, marine and corrosive
environments suitable
ɀ Lowest installed cost
ɀ Allows more luminaires per circuit
ɀ Easy retrofitting when the Lo-Pro TM is the
preferred choice
ɀ Reduces glare and distributes light evenly –
ideal for adverse environments typical of
industrial facilities
ɀ Ideal for adverse environments typical of
industrial facilities
ɀ Easily stocked for quick ship requirements
ɀ For energy conservation, luminaires can be
switched off without affecting the emergency
operation feature

Standard Finishes:
Copper-free aluminum – Corro-free
powdered epoxy
ɀ Krydon – white
ɀ Stainless steel guard

TM

Ratings (Electrical/Size):
Sources/wattage:
ɀ 52W (2-26W lamps) & 64W (2-32W lamps)
ɀ 120-277V, 50-60 Hz
ɀ 347V, 60Hz
ɀ 12, 24, 125 VDC
Conduit entries:
ɀ 3⁄4⍯, 1⍯ NPT – Pendant, Wall Bracket, Ceiling
ɀ 11⁄4⍯ NPT – Stanchion

Certification &
Compliances:
ɀ NEC and CEC:
Class I, Division 1, Groups B
(GB suffix), C, D
Class I, Zone 1 Groups IIB + H2
(GB Suffix),IIB, IIA
Class II, Class III & Simultaneous Presence
(Class I and Class II)
ɀ UL Standards
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
ɀ CSA Standards
C22.2 No. 137

Options:
Description
Group B suitability
Fused
Factory assembled with lamps

Suffix to be added to Cat. #
GB
S658*
FA

Accessories:
Description
Dome reflector
Angle reflector

Cat. #
RD739
RA739

* When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT
in the catalog number.

Standard Materials:
ɀ Mounting modules, cover, ballast housing,
globe holder – copper free aluminum
ɀ Globe – heat and impact resistant glass
ɀ Exterior hardware – stainless steel
ɀ Reflectors (dome & angle) – Krydon TM
fiberglass-reinforced polyester

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:829))
CH0 0 6 L 1 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

829

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0830-2 Name: 6L-830

100:
DATE: JAN 19 2006

Time: 5:54:25 PM Operator: TB

EVLPF Series
Compact Fluorescent

6L

Low Profile Hazard ȿ Gard®
Luminaires

COLOR: CMYK

TCP: 15001

ɀ

ɀ

ɀ

ɀ

Cl. I, Div. 1, Groups B (GB Suffix),C,D
Cl. I, Zone 1, Groups IIB + H2
(GB Suffix), IIB, IIA
ɀ Cl. II, Div 1, Groups E, F, G; Class III,
Simualtaneous Presence

Typedriver Name: TS name csm no.: 100

Marine & Wet Locations
3,3R, 4,4X; IP66

Ordering Information
Pendant
Hub With Guard
Watt Size Catalog #

Wall Brckt†
With Guard
Catalog #

Ceiling†
With Guard
Catalog #

Stanchion
With Guard
Catalog #

Fluorescent—High Power Factor Ballast (Min. P.F. 90%)
EVLPFA02521 EVLPFBX02521 EVLPFCX02521
52W 3⁄4
1
EVLPFA03521 EVLPFBX03521 EVLPFCX03521
EVLPFJ04521
11⁄4
64W 3⁄4
EVLPFA02641 EVLPFBX02641 EVLPFCX02641
1
EVLPFA03641 EVLPFBX03641 EVLPFCX03641
EVLPFJ04641
11⁄4

Pendant Mount

Luminaire Body
Less Mounting
Module & Guard

Catalog #
EVLPF0520

EVLPF0640

Complete Catalog Number as follows:
1. Voltages - Add Suffix as follows:

Standard Voltage Ballasts - 60Hz
Voltage
Suffix

NEC/UL & CEC/CSA (cUL)
120-277V 50-60Hz
/UNV

Optional Ballasts
CEC/CSA (cUL)
347V 60 Hz
/347

125V DC
/125VDC

†Wall Bracket Mount

†Ceiling Mount

Stanchion Mount
†Ceiling and bracket mounts have 4 hubs: 3 are plugged.

830

STIBOINFO((CRH:66008com:6L:830))
CH0 5 L - 1 9

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

12V DC
/012VDC

24V DC
/024VDC

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0831-3 Name: 6L-831

100:
DATE: JAN 19 2006

Time: 5:54:26 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

EVLPF Series
Ordering By Components

6L

EVLP Luminaires are available in components.
A complete light fixture consists of:
I. Mounting Module
II. Fixture Body
III. Guard, Dome Reflector, Angle Reflector or Exit Sign
Mounting Modules
Type
Pendant

Conduit
3⁄4

1
3⁄4
1
Use EV22 or EV33 box with EV87
11⁄4

Ceiling & Wall Box
Wall Bracket Arm
Stanchion
Guards
Fluorescent
Reflectors
Dome
Angle

Catalog Number
EVMP2
EVMP3
EV22
EV33
EV87
EVMJ4
EV512
RD739
RA739

PENDANT
EVMP2
EVMP3

CEILING
EV22
EV33

STANCHION
EVMJ4

CEILING
EV22
EV33

WALL BRACKET
EV87 & EV22 or EV33

FIXTURE BODY
EVLPF0520/UNV
EVLPF0521/UNV
EVLPF0640/UNV
EVLPF0641/UNV

GUARDS
EV511
EV512

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:831))
CH0 0 5 L - 4

DOME REFLECTOR
RD739

CAN: 1-800-265-0502

ANGLE REFLECTOR
RA739

Copyright© 2006 Cooper Crouse-Hinds

831

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0832-2 Name: 6L-832

6L

DATE: JAN 19 2006

Time: 5:54:27 PM Operator: TB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Temperature Performance Data

EVLPF Series
Compact Fluorescent
Low Profile Hazard ȿ Gard®
Luminaires

Fluorescent Fixtures
Maximum Ambient
Fluorescent

832

STIBOINFO((CRH:66008com:6L:832))
CH0 0 5 L - 4

52W & 64W

Class I, Group B
(w/GB suffix)
Groups C, D
Class I Zone I
40°C
T6

US: 1-866-764-5454

Class II Groups E, F, G
Class III
Simultaneous
Presence
40°C
T6

CAN: 1-800-265-0502

Supply Wire °C
75°C

Copyright© 2006 Cooper Crouse-Hinds

Minimum
Operating
Temperature
-18°C

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0833-2 Name: 6L-833

100:
DATE: JAN 19 2006

Time: 5:54:28 PM Operator: TB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Dimensions and Weights

EVLPF Series
Compact Fluorescent

6L

Low Profile Hazard ȿ Gard®
Luminaires

Fluorescent

A
15.69

B
14.69

C
18.25

D
18.46

E
22.34

F
21.30

WEIGHTS (LBS.)
Item
Fluorescent

Weights
31.5

(EVLPF)
Add Mounting Modules
Pendant
Ceiling
Bracket
Stanchion
Add For Reflectors & Exit Sign
RA739
RD739
DMVF–EXD
Deduct for Wire Guard

1
2
4.5
2.5
1
1
5
.5

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:833))
CH0 0 5 L - 4

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

833

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0834-2 Name: 6L-834

6L

100:
DATE: JAN 19 2006

Time: 5:54:29 PM Operator: TB

COLOR: CMYK

TCP: 15001

Photometric Data

EVLPF Series
Compact Fluorescent
Low Profile Hazard ȿ Gard®
Luminaires

Luminaire with Globe and Guard
EVLPFA03641 (2) 32 W Compact Fluorescent
CANDELAS
Mid-Zone
Angle
Candelas
0
174
5
187
15
219
25
263
35
299
45
313
55
315
65
317
75
309
85
284
95
248
105
198
115
135
125
71
135
23
145
3
155
0
165
0
175
0
180
0

834

STIBOINFO((CRH:66008com:6L:834))
CH0 0 5 L - 4

US: 1-866-764-5454

CAN: 1-800-265-0502

ZONAL LUMENS
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

Lumens
18
61
115
174
233
294
345
368
365
321
234
134
51
11
1
0
0
0

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0835-2 Name: 6L-835

100:
DATE: JAN 19 2006

Time: 5:55:33 PM Operator: TB

COLOR: CMYK

TCP: 15001

Photometric Data

EVLPF Series
Compact Fluorescent

Typedriver Name: TS name csm no.: 100

6L

Low Profile Hazard ȿ Gard®
Luminaires
Luminaire with Globe and Dome (Less Guard)
EVLPFA03640RD Lamp: (2) 32 W Compact Fluorescent
CANDELAS
Mid-Zone
Angle
Candelas
0
582
5
595
15
651
25
672
35
644
45
596
55
493
65
331
75
139
85
29
95
10
105
10
115
10
125
6
135
1
145
0
155
0
165
0
175
0
180
0

ZONAL LUMENS
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180

Lumens
57
176
291
384
450
461
347
145
31
11
10
6
1
0
0
0
0
0

Luminaire with Globe and 30° Angle Reflector (Less Guard)
EVLPFA03640RA Lamp: (2) 32 W Compact Fluorescent
CANDELAS
Degrees
0
5
15
25
35
45
55
65
75
85
95
105
115
125
135
145
155
165
175
180

Front
Side
Back
524
524
524
565
526
487
637
528
452
751
541
425
816
550
315
798
551
157
749
453
18
684
258
1
605
93
1
450
20
9
260
10
9
99
10
9
18
9
9
0
1
9
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
ZONAL LUMENS
Zone
Lumens
0-10
51
10-20
152
20-30
255
30-40
337
40-50
371
50-60
353
60-70
301
70-80
230
80-90
144
90-100
71
100-110
15
110-120
7
120-130
2
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:835))
CH0 0 5 L - 4

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

835

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0836-3 Name: 6L-836

6L

DATE: JAN 19 2006

Time: 5:55:38 PM Operator: TB

COLOR: CMYK

TCP: 15001

ɀ

ɀ

ɀ

ɀ

Cl. I, Div. 2, Groups B, C, D
Cl. I, Zone 1, Groups IIC (Suffix S813)
ɀ Cl. II, Div 1, Groups E, F, G
(Suffix S813)
ɀ Cl. II, Div 2, Groups F,G
ɀ Cl. III, Simultaneous Presence

FVS Series
Long Twin Tube
Fluorescent Luminaires

Typedriver Name: TS name csm no.: 100

Marine & Wet Locations
3,3R, 4,4X; IP66

Application:
FVS compact fluorescent luminaires are
used:
ɀ where low mounting heights or limited
mounting room exists.
ɀ for task oriented lighting.
ɀ where a cool, efficient light source is
required.
ɀ in areas that require lamps to reach full
illumination immediately.
ɀ in industrial and chemical processing.
ɀ in pulp and paper facilities.
ɀ in waste or sewage treatment facilities.
ɀ in non-hazardous commercial and
industrial areas.
ɀ in food and pharmaceutical plants where a
non-glass lens is required.
ɀ where fluorescent lighting has been
preferred, but unavailable due to limited
space and practicality.

Features:
ɀ Compact, lightweight, low profile design is
ideal for confined areas and tight corners.
ɀ Reaches full illumination immediately and
delivers light output equivalent to fixtures
twice its size.
ɀ Fast-Latch TM closure provides quick and
easy access for relamping and maintenance
– no tools necessary.
ɀ Silicone sealing gasket provides
exceptional watertight and dust-tight bond,
providing excellent performance in wet and
corrosive environments.
ɀ Power disconnect switch (Cooper CrouseHinds ESWP) automatically cuts power to the
lamps and ballast when the lens is opened.
ɀ Shatter-resistant polymeric lens (.125 thick)
provides environmental and corrosion
protection.
ɀ Available in 120, 277, 220/240 and 347
50/60hz voltages.
ɀ 2 lamp fixture, uses single-ended 40 watt
lamps.
ɀ Multiple mounting capability.
ɀ Energy saving electronic ballast is
standard.

Standard Materials:
ɀ Corrosion-resistant die cast copper-free
aluminum housing.
ɀ Shatter-resistant nylon lens.
ɀ Polycarbonate lens (suffix-S813)
ɀ Silicone rubber gasket.
ɀ Extruded aluminum hinges and closure
hardware with stainless steel pivots.

Standard Finishes:
ɀ Epoxy powder coated housing.
ɀ Anodized hinges and closure hardware.
ɀ Highly specular aluminum reflector.

Size Ranges:
ɀ All luminaires are 24⍯L x 12⍯W x 3.12⍯H.
ɀ Conduit entrances are 3/4⍯.

Certifications and
Compliances:

Accessories

ɀ NEC and CEC:
Class I, Division 2, Groups B,C,D
Class I, Zone 1 Group IIC (suffix S813)
Class II, Division 1, Groups E, F, G
(Suffix S813)
Class II Division 2 Groups F, G
Class III & Simultaneous Presence
(Cl. I and Cl. II)
Note: Aiming Limitations
Cl. II, Cl. III & Simultaneous Presence
Aim down to Horizontal
Cannot aim up
ɀ UL Standards
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
ɀ CSA Standards
C22.2 No. 137

FVS Trunnion Mount Kit (FVS-K5)
ɀ Permits vertical mounting of luminaire on
a beam when used with a standard beam
clamp.
ɀ Can be mounted directly to a wall or
ceiling.
ɀ Can be pole mounted when used in
conjunction with a SFA6 slipfitter adapter
(ordered separately).
ɀ Constructed from copper-free aluminum.
ɀ Supplied with a CGB cord connector.

Options:

Suffix to be added to
Description
Cat. No.
ɀ Fused to protect ballast under
abnormal line conditions. Not available on CSA
certified fixtures.. . . . . . . . . . . . . . . . . . . . . . . S658*
ɀ Fixture supplied with two
F40BX/SPX35 lamps . . . . . . . . . . . . . . . . . . . . S714
ɀ Corro-free TM epoxy finish inside
and out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S753
ɀ Class I, Zone 1, Group IIC and
Class II, Div. 1, Groups E, F, G
suitability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . S813
ɀ Tamperproof . . . consult Cooper Crouse-Hinds

FVS with Trunnion Arm and Slipfitter

Temperature Performance Data:
Style
All
All

Ambient
Temp °C
40°C
55°C

Class I
Div. 2
T3C
T3C

Zone I
T3
—

Class II
See Aiming
T6
—

Simualtaneous
Presence
Limitations
T3C/T6
—

Luminaire Weight (lbs.)
without lamps
ɀ Standard 2 lamp FVS . . . . . . . . . . . . . . . . 12.0

Electrical Ratings:
ɀ 120-277V, 50-60 Hz
ɀ 347V, 60Hz
ɀ Two 40 watt long twin tube lamps

836

STIBOINFO((CRH:66008com:6L:836))
CH0 5 L - 2 7

* When ordering Fuses for luminaires, option S658, you
must specify the operating voltage. S658 can not be ordered
with /MT in the catalog number.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Supply
Wire
75°C
75°C

Minimum
Operating
Temperature
-18°C (0°F)
-18°C (0°F)

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0837-3 Name: 6L-837

DATE: JAN 19 2006

FVS Series
Long Twin Tube
Fluorescent Luminaires

Time: 5:55:40 PM Operator: JB

COLOR: CMYK

ɀ

ɀ

ɀ

ɀ

Cl. I, Div 2, Groups B,C,D
Cl. I, Zone 1 Group IIC (suffix S813)
ɀ Cl. II, Div 1,Groups E,F,G (suffix S813)
ɀ Cl. II, Div 2, groups F,G
ɀ Cl. III, Simultaneous Presence

TCP: 15001

Typedriver Name: TS name csm no.: 100

Marine & Wet Locations
3,3R, 4,4X; IP66

6L

Luminaire includes all necessary provisions for these installations:

Ceiling Mount

Pendant Mount

Corner Mount

FVS compact fluorescent (2 lamp luminaire):

Voltage

Wattage/
Lamp

Hub
Size (4)

Cat.
Number

Cat. # with
Class I, Zone 1
and Class II,
Div. 1 Suitability

120 (50 or 60 Hz)
277 (50 or 60 Hz)
120–277 (50 or 60 Hz)
347 (50 or 60 Hz)

40
40
40
40

3⁄4⍯

FVS20
FVS27
FVS20UNV
FVS23

FVS20–S813
FVS27–S813
FVS20UNV–S813
FVS23–S813

3⁄4⍯
3⁄4⍯
3⁄4⍯

Horizontal Wall Mount Vertical Wall Mount

Accessories
Separately

Ordered

ɀ Trunnion arm kit . . . . . . . . . . . . . . . . . FVS-K5
ɀ Slipfitter adapter to be used with
trunnion arm . . . . . . . . . . . . . . . . . . . . . . SFA6

Dimensions:

FVS with Trunnion Arm: 261⁄4⍯ × 13.5⍯W × 3.12⍯H
Side View

Top View

FVS Showing
Mounting Strap Positioning

FVS With Lens Open

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:837))
CH0 5 L - 2 8

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

837

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0838-2 Name: 6L-838

DATE: JAN 19 2006

Time: 5:55:48 PM Operator: TB

FVS Series
Long Twin Tube

6L

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

Fluorescent Luminaires

Luminaire: FVS
Lamp: (2) F40BX/SPX35/RS single-ended fluorescent.

Total initial lumens: 6300

Isofootcandle Chart

Coefficients of Utilization
Effective Floor Cavity Reflectance 20%
Eff.
Ceil.
80*

70*

50*

Footcandle Values for Isofootcandle Lines
Mtg.
Hgt.
8′
10′
12′
16′

A
5.00
3.20
2.22
1.25

B
3.00
1.92
1.33
0.75

C
1.00
0.64
0.44
0.25

D
0.50
0.32
0.22
0.13

E
0.20
0.13
0.09
0.05

30*

10*
0*

Wall
50*
30*
10*
50*
30*
10*
50*
30*
10*
50*
30*
10*
50*
30*
10*
0*

1
.621
.594
.569
.606
.582
.560
.580
.560
.541
.555
.539
.524
.533
.520
.507
.494

2
.538
.495
.459
.526
.487
.453
.503
.470
.442
.483
.455
.431
.464
.441
.421
.407

3
.469
.419
.378
.459
.412
.374
.441
.400
.367
.423
.389
.360
.407
.378
.353
.339

Room Cavity Ratio
4
5
6
.414 .367 .329
.359 .312 .273
.317 .270 .234
.405 .360 .323
.354 .308 .270
.314 .268 .232
.389 .347 .311
.345 .300 .265
.310 .265 .230
.374 .334 .301
.336 .293 .259
.305 .262 .227
.361 .322 .290
.327 .287 .254
.300 .258 .225
.286 .245 .212

* Percent Reflectance

Spacing to Mounting Height Ratio
Along lamp axis (A-A)
0.6
Across lamp axis (B-B) 1.1
* FVS suitable for Class II, Div. 1, Groups E, F, G when ordered with suffix S813.

838

STIBOINFO((CRH:66008com:6L:838))
CH0 5 L - 2 9

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

7
.297
.242
.204
.291
.240
.203
.281
.235
.201
.272
.230
.199
.264
.226
.197
.185

8
.269
.216
.180
.265
.214
.179
.256
.210
.178
.248
.207
.176
.241
.203
.175
.163

9
.246
.195
.160
.242
.193
.160
.234
.190
.159
.227
.187
.157
.221
.184
.156
.145

10
.225
.176
.144
.222
.175
.143
.216
.172
.143
.210
.170
.142
.204
.167
.141
.130

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0839-3 Name: 6L-839

100:
DATE: JAN 19 2006

EVFT Illuminator TM
Long Twin Tube
Fluorescent Luminaires

Time: 5:55:49 PM Operator: TB

COLOR: CMYK

TCP: 15001

ɀ

ɀ

ɀ

ɀ

Cl. I, Div, Groups B & C(suffix GB), D
Cl. I, Zone 1 Group IIB + H2(suffix GB),
IIA
ɀ Cl. II, Div 1, Groups E,F,G
ɀ Cl. III Simultaneous Presence

Typedriver Name: TS name csm no.: 100

Paint Spray
Marine & Wet
Locations
ɀ 3,3R, 4,4X; IP66

6L

Application:
Illuminator TM compact fluorescent luminaires
are used:
ɀ In areas made hazardous by the presence
of flammable gases and vapors, combustible
dusts, or easily ignitable fibers and flyings.
ɀ In areas where combustible dusts and
flammable gases are present simultaneously.
ɀ In applications involving low mounting
heights, restricted mounting space, or where
luminaire weight must be minimized.
ɀ In areas where corrosion, vibration,
moisture, dirt and rough usage are a
problem.
ɀ In refineries, chemical and petrochemical
facilities, grain processing, handling and
storage facilities, manufacturing plants, waste
water treatment facilities, airline and mass
transit maintenance areas, paint spray
facilities, breweries, pharmaceutical plants
and other areas where safe, reliable
hazardous area lighting is required in a
compact, cool operating and efficient light
source.

Features:
ɀ Efficient fluorescent light source in 78 and
156 watts.
ɀ Adjustable right and left asymmetrical
reflectors provide excellent light ‘‘aimability’’
– ideal for task oriented lighting.
ɀ Compact, light weight and low profile
design allows easy installation and broad
industrial application.
ɀ Cast copper-free aluminum with epoxy
powder finish (less than 0.4 of 1% copper)
provides excellent resistance to corrosion.
ɀ Versatile luminaire housing provides choice
of pendant, wall or ceiling mount.
ɀ Suitable for paint spray areas. Linear light
source provides excellent color rendition for
paint spray tasks. Easy to install, disposable,
clear tube wrap helps maintain maximum
light output during painting operations.
ɀ Threaded construction, factory wiring and
sealing help minimize installation time. No
external seals are required.
ɀ Fixtures are used with two or four long twin
tube single-ended fluorescent lamps.
ɀ Optional stainless steel guard provides
extra protection for lamps and lamp tube.
ɀ Optional clear polycarbonate tube provides
360° protection for lamps and lamp tube;
ideal for maintenance pit and pharmaceutical
applications.
ɀ Grounding connection for safety.
ɀ Available for 120 or 277 VAC.
ɀ Standard electronic ballast.

4 lamp with stainless steel wire guard and adjustable reflectors

Certifications and
Compliances:

Electrical Ratings:

ɀ NEC and CEC:
Class I, Division 1 Group D
Class I, Division 1 Group B,C,D (suffix GB)
Class I, Zone 1 Group IIA
Class I, Zone 1 Group IIB + H2 (suffix GB)
Class II Groups E,F,G
Class III
Simultaneous Presence (Cl. I and Cl. II)
Paint Spray
Note: Aiming Limitations
Cl. II, Cl III & Simultaneous Presence
– Aim Down to Horizontal
– Cannot aim up
ɀ UL Standards
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
ɀ CSA Standards
C22.2 No. 137

ɀ Input voltage – 120 or 277 VAC, 60Hz
ɀ Wattages – 78 – 2-lamp luminaire
156 – 4-lamp luminaire

Options:

Suffix to be added
to Catalog Number
ɀ Fused to protect circuit under abnormal
conditions (not available on CSA certified
luminaires). . . . . . . . . . . . . . . . . . . . . . . . . S658*
ɀ Luminaire supplied with lamps . . . . . . . S714
ɀ Class I, Groups B and C suitability
Pendant mount only! . . . . . . . . . . . . . . . . . GB

Fixture Weights (lbs.):
Illuminator – 2 lamp with guard . . . . . . . . . 19.5
Illuminator – 4 lamp with guards . . . . . . . . 36.5
RAL1, RAR1 reflectors (each) . . . . . . . . . . . . 3.0
Deduct for luminaire without P51 Guard:
1 lb. for 2 lamp
2 lbs. for 4 lamp

Standard Materials:
ɀ Center and ballast housings, end caps –
copper-free aluminum
ɀ Lamp tube – heat resistant glass.
ɀ Guards – stainless steel or clear
polycarbonate material.
ɀ Reflectors – aluminum

Standard Finishes:
ɀ Center and ballast housings, end caps,
guards – natural
ɀ Reflectors – white epoxy finish

Temperature Performance Data:
Luminaire
Type

Minimum
Operating
Temp.

Maximum
Ambient
Temp.

Class I, Division 1 & Zone 1
Class II, Division 1
Simultaneous Presence

Supply
Wire

2 and 4
Lamp

10°C
(50°F)

40°C
(104°F)

T4A

75°C

* When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT
in the catalog number.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:839))
CH0 5 L - 3 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

839

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0840-2 Name: 6L-840

6L

DATE: JAN 19 2006

EVFT Illuminator TM
Long Twin Tube
Fluorescent Luminaires

Time: 5:55:53 PM Operator: TB

COLOR: CMYK

TCP: 15001

ɀ

ɀ

ɀ

ɀ

Cl. I, Div 1, Groups B & C (Suffix B),D
Cl. I, Zone 1, Groups IIB + H2
(Suffix B), IIA
ɀ Cl. II, Div 1, Groups E, F, G
ɀ Cl. III, Simultaneous Presence

Typedriver Name: TS name csm no.: 100

Paint Spray
Marine & Wet Locations
ɀ 3,3R, 4,4X; IP66

EVFT Illuminator
Hub
Size
3⁄4
2 Lamp 3
⁄4
3⁄4
4 Lamp 3
⁄4

Style

Luminaire
Voltage
120
277
120
277

Class I
Cat. No. with Group D Suitability
Without
With
Guard
P51 Guard†
EVFT22320
EVFT22321
EVFT22370
EVFT22371
EVFT24320
EVFT24321
EVFT24370
EVFT24371

Class I
Cat. No. with Group B, C & D Suitability
Without
With
Guard
P51 Guard†
EVFT22320–GB
EVFT22321–GB
EVFT22370–GB
EVFT22371–GB
EVFT24320–GB
EVFT24321–GB
EVFT24370–GB
EVFT24371–GB

† P51 supplied in separate carton.

Accessories
ɀ Stainless steel wire guard . . . . . . . . . . . . P51
ɀ Reflector right hand . . . . . . . . . . . . . . . . RAR1
ɀ Reflector left hand . . . . . . . . . . . . . . . . . . RAL1
ɀ Polycarbonate tube . . . . . . . . . . . . . . . . . PG1
(not used with optional stainless steel wire
guard)
ɀ Disposable clear wrap – 5 pack. . . . . . PTW1
(for use with optional polycarbonate tube)

Note: Aiming Limitations: In Class II, Class III and Simultaneous Presence locations
ɀ Aim down to Horizontal.
ɀ To prevent dust from accumulating in reflector, do not aim up.

Dimensions
Illuminator two lamp luminaire with Reflector

RAR1
RAL1
Reflectors (as viewed facing front of fixture).

Stainless steel guard
Illuminator four lamp luminaire with Reflectors

Polycarbonate tube and retaining plate

ɀ For GB suffix (Groups B & C) this dimension is 34.0⍯. For CSA certified fixtures this dimension is 359⁄16⍯.
ɍ For GB suffix (Groups B & C) this dimension is 8.38⍯.
Disposable polyester tube wrap
(used over optional polycarbonate tube)

840

STIBOINFO((CRH:66008com:6L:840))
CH0 5 L - 3 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0841-3 Name: 6L-841

DATE: JAN 19 2006

Time: 5:55:55 PM Operator: TB

COLOR: CMYK

TCP: 15001

Photometric Data

EVFT Illuminator TM
Long Twin Tube

Typedriver Name: TS name csm no.: 100

6L

Fluorescent Luminiaires

Illuminator two lamp luminaire with Reflector (without Guard)
Lamps: (2) 39 watt BIAX* fluorescent

DEGREES
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180

CANDELAS
in Plane A-A
LEFT
RIGHT
729
729
792
797
820
821
757
777
648
709
567
632
474
535
340
469
201
312
102
116
9
7

Plane B-B
SIDE
729
703
658
582
488
370
239
109
21

LEGEND
PLANE A-A ACROSS LAMP AXIS
– – – – PLANE B-B ALONG LAMP AXIS

Footcandle Values for Isofootcandle Lines
MTG. HT
(FT) A
B
C
D
E
F
8 10.0 5.00 2.00 1.00 0.50 0.25
10
6.4 3.20 1.28 0.64 0.32 0.16
12
4.4 2.22 0.89 0.44 0.22 0.11
16
2.5 1.25 0.50 0.25 0.13 0.06

Illuminator four lamp luminaire with Reflectors (without Guards)
Lamps: (4) 39 watt BIAX* fluorescent

DEGREES
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180

CANDELAS
in Plane A-A
LEFT
RIGHT
1486
1486
1601
1520
1633
1615
1570
1602
1530
1558
1343
1390
1162
1208
803
921
375
488
136
168
13
18
2
6
1
4
2
1
2
2

1
2

Plane B-B
SIDE
1486
1448
1346
1199
1000
763
492
225
45
2
1

1
1
1
1
2

LEGEND
PLANE A-A ACROSS LAMP AXIS
– – – – PLANE B-B ALONG LAMP AXIS

Footcandle Values for Isofootcandle Lines
MTG HT
(FT) A
B
C
D
E
F
10 8.0 4.00 2.00 1.00 0.50 0.20
12 5.6 2.78 1.39 0.69 0.35 0.14
16 3.1 1.56 0.78 0.39 0.20 0.08
20 2.0 1.00 0.50 0.25 0.13 0.05

* BIAX is a trademark of the General Electric Company.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:841))
CH0 5 L - 3 2

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

841

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0842-2 Name: 6L-842

DATE: JAN 19 2006

Time: 5:55:56 PM Operator: TB

TCP: 15001

Typedriver Name: TS name csm no.: 100

Coefficients of Utilization

EVFT Illuminator TM
Long Twin Tube

6L

COLOR: CMYK

Fluorescent Luminaires

LUMINAIRE: EVFT 22320 with RAR1 Reflector
Lamps: Two (2) F39BX/SPX35/RS
Lumen Rating: 2900 Lumens/Lamp
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall
0
1

2

3

Room Cavity Ratio
4
5

6

7

8

9

10

80

70
50
30
10

.51
.51
.51
.51

.46
.44
.41
.40

.41
.38
.35
.32

.38
.33
.29
.26

.34
.29
.25
.22

.31
.25
.21
.18

.29
.23
.19
.16

.26
.20
.16
.14

.24
.18
.14
.12

.22
.16
.13
.10

.21
.15
.11
.09

70

70
50
30
10

.49
.49
.49
.49

.45
.43
.41
.39

.40
.37
.34
.31

.37
.32
.29
.26

.33
.28
.25
.22

.30
.25
.21
.18

.28
.22
.18
.16

.26
.20
.16
.14

.24
.18
.14
.12

.22
.16
.12
.10

.20
.14
.11
.09

50

50
30
10

.47
.47
.47

.41
.39
.38

.35
.33
.31

.31
.28
.26

.27
.24
.22

.24
.21
.18

.21
.18
.16

.19
.16
.13

.17
.14
.12

.15
.12
.10

.14
.11
.09

30

50
30
10

.45
.45
.45

.39
.38
.37

.34
.32
.30

.30
.27
.25

.26
.24
.21

.23
.20
.18

.21
.18
.15

.19
.16
.13

.17
.14
.11

.15
.12
.10

.14
.11
.09

10

50
30
10

.43
.43
.43

.37
.36
.35

.33
.31
.29

.29
.27
.25

.25
.23
.21

.22
.20
.18

.20
.17
.15

.18
.15
.13

.16
.13
.11

.14
.12
.10

.13
.10
.08

0

0

.43

.35

.28

.24

.20

.17

.14

.12

.10

.09

.08

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

LUMINAIRE: EVFT 24320 with RAR1 & RAL1 Reflectors
Lamps: Four (4) F39BX/SPX35/RS
Lumen Rating: 2900 Lumens/Lamp

Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall
0
1

2

3

Room Cavity Ratio
4
5

6

7

8

9

10

80

70
50
30
10

48
.48
.48
.48

.44
.42
.40
.39

.40
.37
.34
.31

.37
.32
.29
.26

.33
.29
.25
.22

.30
.25
.21
.19

.28
.22
.19
.16

.26
.20
.16
.14

.24
.18
.14
.12

.22
.16
.13
.10

.20
.15
.11
.09

70

70
50
30
10

.47
.47
.47
.47

.43
.41
.40
.38

.39
.36
.33
.31

.36
.32
.29
.26

.33
.28
.25
.22

.29
.25
.21
.18

.27
.22
.18
.16

.25
.20
.16
.14

.23
.18
.14
.12

.21
.16
.12
.10

.20
.14
.11
.09

50

50
30
10

.45
.45
.45

.39
.38
.37

.34
.32
.30

.30
.28
.26

.27
.24
.22

.24
.21
.18

.21
.18
.16

.19
.16
.14

.17
.14
.12

.15
.12
.10

.14
.11
.09

30

50
30
10

.43
.43
.43

.38
.37
.36

.33
.31
.30

.29
.27
.25

.26
.23
.21

.23
.20
.18

.20
.18
.16

.18
.16
.13

.17
.14
.12

.15
.12
.10

.14
.11
.09

10

50
30
10

.41
.41
.41

.36
.35
.35

.32
.30
.29

.28
.26
.25

.25
.23
.21

.22
.20
.18

.20
.17
.15

.18
.15
.13

.16
.13
.12

.14
.12
.10

.13
.11
.09

0

0

.41

.34

.28

.24

.20

.17

.15

.13

.11

.09

.08

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

842

STIBOINFO((CRH:66008com:6L:842))
CH0 5 L - 3 3

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0843-11 Name: 6L-843

DATE: JAN 19 2006

Time: 5:55:57 PM Operator: JB

COLOR: CMYK

ɀ

ɀ

ɀ

ɀ

Higher Ambient Suitability: 55°C
Cold Weather Start (32W T8 Lamps)
ɀ Cl. I, Div 2, Groups A, B, C, D
ɀ Cl. I, Zone 2 Group IIC

NFL Series
Fluorescent
Luminaires

TCP: 15001

Typedriver Name: TS name csm no.: 100

Wet Locations
3, 3R, 4, 4X

6L

Application:
The NFL light luminaires are used:
ɀ In non-hazardous locations where dust,
dirt, combustible vapors, smoke, fumes,
moisture, corrosive & wet conditions are
present.
ɀ Where lamps may be broken due to
physical abuse or movable equipment, such
as in manufacturing areas or warehouses.
ɀ Where cleanliness and sanitation are prime
factors such as in dairies, canneries, food
processing plants, bottling plants &
laboratories.
ɀ In dock areas for protection against salt
spray.
ɀ In areas where low mounting height and the
even light distribution associated with a line
type light source are required.

Standard Materials:

ɀ Housing – Non-metallic, one piece
fiberglass reinforced polyester
ɀ Latches – Celcon TM acetal plastic
ɀ Crepe Pattern Lens – Acrylic plastic
ɀ Gasket – Seamless thermoset polyurethane
ɀ Mounting Bracket – Stainless steel

Standard Finishes:
ɀ Fiberglass housing – White
ɀ Acrylic Plastic lens – Clear

Key Features

ɀ Molded in place mounting studs –
eliminate the need of bracket gaskets
ɀ Standard construction includes:
S.S. mounting brackets
Electronic ballast
Cold weather ballast (4′ F32 T8)
ɀ S.S. mounting bracket
Combination ceiling & chain

Certifications and
Compliances:
ɀ UL Listed 844
ɀ cUL
ɀ Wet locations
ɀ 4X

Ratings (Electrical/Size):
Sources/Wattage: Luminaires are for use
with the following lamps
ɀ NFL2140
– one 40 W long twin tube
ɀ NFL4232
– two 32W T8 lamps
ɀ NFL4240
– two 34W ‘‘F40 Style’’ T12 lamps
Voltages
ɀ 120V 60Hz
ɀ 120 - 277V, 50 - 60 Hz
ɀ 347V 60Hz
Conduit Entries
ɀ Two 1⁄2⍯ inch Myers hubs, one on each end.

ɀ S.S. mounting brackets
ɀ Electronic Ballast
ɀ Cold Weather Ballast (4′ F32 T8)
ɀ Two 1⁄2⍯ conduit Myers hubs for end and
feed through wiring
ɀ Full metal fixture interior
ɀ Provisions (drill mark) on 4 ft. unit to field
drill for pendant mounting

Options:
Description

Suffix to be
added to Cat. No.
ɀ Fused . . . . . . . . . . . . . . . . . . . . . . . . .S658‡
ɀ Factory assembled with lamps
installed . . . . . . . . . . . . . . . . . . . . . . . . .FA
ɀ Battery Backup Emergency
Ballast †
(NFL 2140 and NFL 4232 only) . . . . .S799*
ɀ Increased Impact-Resistant
Acrylic Lens . . . . . . . . . . . . . . . . . . . . .DR1295046*
ɀ Polycarbonate Lens . . . . . . . . . . . . .DR1295306*
ɀ Stainless Steel Latches . . . . . . . . . .S863*
ɀ Tamperproof Latches . . . . . . . . . . .S861*
 – available with Lightning Service TMdelivery See Section G
for complete details
† For non-hazardous locations
‡ When ordering Fuses for luminaires, option S658, you
must specify the operating voltage. S658 can not be ordered
with /MT in the catalog number.
* UNV voltages: 120, 208, 230, 240, 277, 50-60 Hz

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:843))
CH0 0 5 L - 3

Benefits

ɀ UL, cUL Listed for Class I, Division 2,
Groups A, B, C, D areas with ambient
suitability of 40°C (104°F) and 55°C
(131°F) Ambient suitability
ɀ NEMA 4X with Myers Hubs and threaded
metal plug (furnished)
ɀ Non-metallic construction enclosure
ɀ Continuous form in place gasket

Suitable for higher ambients found in industrial
environments. Exceeds the 25°C (77°F)
ambient suitability of ordinary location lighting
fixtures.
Outdoor locations, hose down and corrosive
environments suitable.
Corrosion resistant.
Insure dust tight, moisture tight, & wet
locations integrity.
Wet locations, and dust tight integrity is not
compromised by aging or deteriorated bracket
gaskets.
Eliminates the need to order options with
associated long lead times.

Standard bracket not only surface mounts
fixture, but also is for chain mounting using
standard commercially available fixture chain.
Superior corrosion resistance.
Energy efficiency.
Cold weather start up requirements.
Simplify installation and wiring.
Provides improved photometrics as well as
access to & concealment of ballast and wiring.
Application and installation flexibility.

Temperature Performance
Data:

Ambient temperature range suitability:
ɀ Two lamp, 32W T8, 4 ft
luminaire
–18°C to 55°C
ɀ ALL others
0°C to 55°C
ɀ Supply wire
75°C min.
Celecon TM is a trade name of Hoechst Celanese

Ordering Information:
Luminaire Cat # Size/# of lamp(s) Wattage/Lamp type Voltage/Hz
NFL2140/UNV
2 ft/ 1-lamp
40W T5 compact
120/60
NFL2140/347
single ended
120-277/50-60
347/60
NFL4232/UNV 4 ft/2-lamp
32W T8
120/60
rapid start
120-277/50-60
NFL4240/120
4ft/2-lamp
34W T12
120/60
NFL4240/277
‘‘F40 Style’’
277/60
NFL4240/347
rapid start
347/60
N2FL4232/UNV
N2FL4232/347
4ft/2-lamp
32W T8
347/60
rapid start

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

843

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0844-2 Name: 6L-844

6L

100:
DATE: JAN 19 2006

Time: 5:55:58 PM Operator: TB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

NFL Series
Fluorescent Luminaires

Luminaire: All NFL Luminaires
To determine number and placement of luminaires, see Lighting Selector Guide in Section L
Candlepower Distribution Curve (in Candelas)
CANDELAS
Angle Along Across
0°
1049
1049
10°
1034
1056
20°
978
1071
30°
866
1075
40°
762
1027
50°
606
939
60°
416
838
70°
228
723
80°
92
549
90°
17
363
100°
19
243
110°
10
131
120°
5
46
130°
4
20
140°
4
9
150°
4
3
160°
4
0
170°
0
0
180°
0
0
ZONAL LUMENS
Zone
Lumens
0–30
862
0–40
1462
0–60
2778
0–90
4130
0–180
4499

Photometric data, developed using two (2) F32T8/35K
2850 lumen lamps, represents the performance of all NFL
series luminaires.
ɀ Coefficient of Utilization – These values are for all NFL
series luminaires (Do not use multipliers).
ɀ Candlepower Distribution Cuarve (in candelas) and
Zonal Lumens – These values are for all NFL series
luminaires, adjusted by conversion factors (multipliers)
below.
Luminaire Lamp
Series
Qty Watts
NFL4232 2
32
NFL4240 2

34

NFL2140 1

40

Type
(Lumens ea.)
F32T8/35K
(2850)
F40T12/RS
(2650)
T5 Compact
(3150)

Conversion
Factor
(multipliers)
1.0
0.93
0.55

Example:
ɀ Candlepower at 20° across for NFL4232 using 2F32T/35K lamps (5700 lumen total) is 1071 candelas.
ɀ Candlepower at 20° across for NFL2140 using 1 T5
compact lamp (3100 lumen total) is 1071 x .55 ⍧ 589
candelas.

Coefficient of Utilization: For all NFL Series Light Luminaires
Effective Floor Cavity Reflectance 20%
% REFLECTANCE
Eff. Ceiling
Wall
70
80
50
30
10
70
70
50
30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0

844

STIBOINFO((CRH:66008com:6L:844))
CH0 0 5 L - 4

1
.83
.78
.74
.71
.80
.76
.72
.69
.71
.68
.66
.67
.65
.62
.63
.61
.59
.57

2
.75
.67
.61
.56
.72
.65
.60
.55
.61
.57
.53
.58
.54
.51
.54
.51
.48
.46

US: 1-866-764-5454

3
.68
.59
.52
.46
.65
.57
.51
.46
.54
.48
.44
.51
.46
.42
.48
.44
.41
.39

4
.62
.52
.44
.39
.59
.50
.43
.38
.47
.42
.37
.45
.40
.36
.42
.38
.35
.33

CAN: 1-800-265-0502

ROOM CAVITY RATIO
5
6
.56
.51
.45
.40
.38
.33
.32
.28
.54
.49
.44
.39
.37
.32
.32
.27
.42
.37
.35
.31
.31
.26
.39
.35
.34
.30
.30
.26
.37
.33
.33
.29
.29
.25
.27
.23

7
.47
.36
.29
.24
.46
.35
.28
.23
.33
.27
.23
.32
.26
.22
.30
.25
.22
.20

Copyright© 2006 Cooper Crouse-Hinds

8
.44
.32
.25
.20
.42
.31
.25
.20
.30
.24
.20
.28
.23
.19
.27
.22
.18
.17

9
.40
.29
.22
.17
.39
.28
.22
.17
.27
.21
.17
.25
.20
.16
.24
.19
.16
.14

10
.37
.26
.20
.15
.36
.26
.19
.15
.24
.19
.15
.23
.18
.14
.22
.17
.14
.12

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0845-5 Name: 6L-845

100:
DATE: JAN 19 2006

Time: 5:55:59 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Dimensions and Weights

NFL Series
Fluorescent Luminaires

6L

Dimensions:

Net Luminaire Weights (lbs)
Luminaire Series
NFL2140
NFL4232
NFL4240

Weight (lbs.)
9.1
14.3
14.3

Temperature Performance Data
Basic
Watts
Cat #

Ambient
Temp °C

Lamp
Type

Supply Wire
Temp °C

Class I, Div. 2
Temp. Rating

Class II
Temp. Rating

NFL4232
NFL4232
NFL4240
NFL4240
NFL2140
NFL2140

40
55
40
55
40
55

T8
T8
T12
T12
T12
T12

60
75
60
75
60
75

T6
T5
T6
T5
T6
T5

-

32
32
34
34
40
40

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:845))
CH0 0 5 L - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Simultaneous
Presence Class
1, Div. 2
-

845

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0846-11 Name: 6L-846

6L

DATE: JAN 19 2006

Time: 5:56:00 PM Operator: GK COLOR: CMYK

TCP: 15001

ɀ

ɀ

ɀ

ɀ

Cl. I, Div 2, Groups B,C,D
Cl. I, Zone 1 Group IIC
ɀ Cl. II, Div Groups E,F,G(Canada)
ɀ Cl. II, Div 2, Groups F,G (US)
ɀ Cl. III, Simultaneous Presence

eLLK Series
Fluorescent
Nonmetallic
Luminaires

Typedriver Name: TS name csm no.: 100

Wet Locations
3,3R,4,4X; IP66
ɀ ATEX Certified

Application:
ɀ eLLK fixtures are used in hazardous area
where moisture or corrosion may be a
problem.
ɀ Offshore oil platforms, Pharmaceuticals,
plants, Oil refineries.
ɀ Where battery backup is critical.
ɀ In non-hazardous and industrial locations.

Features:
ɀ IEC: Zone 1 and 2 areas.
ɀ NEC/CEC: Zone 1, Division 2 areas.
ɀ Electronic Ballast:
ɀ Operates at Voltage range of 110-254 VAC
± 10%, 50-60Hz.
ɀ Lower ambient temperature suitability to
–25°C.
ɀ Lamps operate indepenently - one lamp
failure will not effect remaining lamp
operation.
ɀ Standard Bi-pin Lamps - Most common
lamp used in office enviroments. Energy
efficient and cost effective.
ɀ Interlocked Switch - Automatically cuts
power to both lamps and ballast when the
lens is opened.
ɀ Removable Lens - Hinged on both sides for
easy installation and maintenance.
ɀ Dual entries - Extra large wire well
eliminates need for seperate junction boxes.
(Own with cable gland and conduit hub).
ɀ Corrosion-Resistant Construction - Nonmetallic body, gasketed lenses, and lens
locking system for an IP 66, NEMA 4X rating.
ɀ Battery Backup Features:
ɀ Operates one lamp for 11⁄2 hours should
power go out.
ɀ Microprocessor monitors the charging
functions of the battery.
ɀ LEDs provide visual indication of battery
life.

Certifications and Compliances:
ɀ NEC and CEC:
Class I, Division 2 Group B, C, D
Class I, Zone 1 Group IIC
Class II Division 1, Groups E,F,G (Canada)
Class II Division 2, Groups F, G (US)
Class III, Simultaneous Presence (Cl. I and Cl. II)
ɀ UL Standards
2279 Hazardous (Classified) Locations
1598 Luminaires
ɀ CSA Standards
E79 Series
II 2 G
ɀ ATEX Directive 94/9/EC
II 2 D T80°C
ɀ Type of Protection
EEx edm ib IIC T4
ɀ EC-Type Examination
PTB 96 ATEX 2144
Certificate

Ordering Information:
Type - 2 Lamp
18W
36W
18W
18W (with battery)
18W (with battery)
36W
36W (with battery)
36W (with battery)

Length & Type
2-foot T8
4-foot T8
2-foot T8
2-foot T8
2-foot T8
4-foot T8
4-foot T8
4-foot T8

Conduit Hub Size*
M25 metric hub
M25 metric hub
3/4⍯ Myers hub
3/4⍯ Myers hub
3/4⍯ Myers hub
3/4⍯ Myers hub
3/4⍯ Myers hub
3/4⍯ Myers hub

Rated Current
0.18A
0.34A
0.18A
0.23A
0.23A
0.34A
0.40A
0.40A

Rated Voltage
±10%, 47-63Hz
110-254
110-254
110-254
110-120
220-254
110-254
110-120
220-254

Order Number
1 2265 875 103
1 2266 875 103
1 2265 875 311
1 2260 879 333
1 2260 879 311
1 2266 875 311
1 2261 879 333
1 2261 879 311

Description
eLLK92018/UNV
eLLK92036/UNV
eLLK92018/UNV
eLLK92018/18/NIB
eLLK92018/18/NIB WH
eLLK92032/UNV
eLLK92036/36/NIB
eLLK92036/36/NIB

* 2 hubs provided. May be connected throughfeed or
tandam. Cable glands ordered separately for 3⁄4⍯ (remove
hubs) or M 25 openings (remove hubs).

Lamp Selection:
Phillips
GE
Osram/Sylvania

846

STIBOINFO((CRH:66008com:6L:846))
CH0 5 L - 3 0

Weight
17W

32W

F17T8/Tl841
F17T8/SPX41
F017/841

F32T8/TL841
F32T8/SPX41
FO32/841

US: 1-866-764-5454

CAN: 1-800-265-0502

17 W
17 W (battery)
32 W
32 W

Copyright© 2006 Cooper Crouse-Hinds

4.6 Kg (10 Ib)
10 Kg (22 Ib)
6.7 Kg (14 Ib)
12 Kg (26 Ib)

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0847-4 Name: 6L-847

100:
DATE: JAN 19 2006

Time: 5:56:01 PM Operator: JB

TCP: 15001

Typedriver Name: TS name csm no.: 100

Accessories
Dimensions

eLLK Series TM
Fluorescent Nonmetallic
Luminaires
Accessories

COLOR: CMYK

6L

Dimensions: (mm)
Standard Luminaire with Backup

Eyebolt

Hexagonal Screw
Type
Eyebolt
Hexagon Screw S4
Ceiling Mounting
D92 Bracket
Pipe Clamp

Ceiling Mounting Bracket

Corrosion
Protection
Galvanized
Cr Ni

Pipe
Outer
Quantity per
Din OD (mm) Luminaire
—
—
2
—
—
2

Order
Number
2 2480 002 000
2 2480 054 000

Cr Ni
R12 Hot Galvanized
R14 CrNi
R22 Hot Galvanized
R32 Hot Galvanized

—
11⁄4⍯
11⁄4⍯
11⁄2⍯
2⍯

—
38–42
38–42
47–51
56–60

2
2
2
2
2

2 2480 092 000
2 2480 462 000
2 2480 464 000
2 2480 472 000
2 2480 482 000

—

—

—

—

3 2485 000 005

Hexagon Key SW13
eLLK 92

Pipe Clamp

Wall Bracket

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:847))
CH0 5 L - 3 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

847

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0848-2 Name: 6L-848

DATE: JAN 19 2006

Time: 5:57:02 PM Operator: TB

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

eLLK Series TM
Fluorescent Nonmetallic
Luminaires

6L

COLOR: CMYK

Photometric data developed
using 2 – F32T8 3350
lumen lamps.
For the 17 W eLLK, use a
0.45 multiplier.

Coefficients of Utilization
Effective Floor Cavity Reflectance 20%
Wall
70*
50*
30*
10*

Work
20*
20*
20*
20*

Room Cavity Ratio
1
2
3
41
49
55
30
38
44
23
30
36
18
25
30

4
61
50
43
37

5
65
55
48
42

6
70
62
55
50

7
74
67
61
56

8
77
71
65
61

9
80
75
70
66

70*
50*
30*
10*

20*
20*
20*
20*

40
29
22
18

47
37
30
24

53
42
35
30

58
49
42
36

62
54
47
42

68
60
54
49

71
65
59
54

74
68
64
59

77
72
68
64

50*

50*
30*
10*

20*
20*
20*

27
21
17

35
28
24

40
34
29

46
40
35

50
45
40

56
51
47

61
56
52

64
60
57

68
64
61

30*

50*
30*
10*

20*
30*
20*

26
20
17

38
27
23

37
32
28

43
38
34

47
43
39

58
49
45

57
53
50

60
57
54

64
61
58

10*

50*
30*
10*

20*
20*
20*

24
20
16

31
26
22

35
31
27

41
36
33

45
41
37

50
46
43

54
51
48

57
54
52

60
68
55

0*

0*

20*

14

20

25

31

35

41

46

49

53

Eff. Ceil.
80*

70*

* Percent Reflectance

848

STIBOINFO((CRH:66008com:6L:848))
CH0 5 L - 3 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0849-16 Name: 6L-849

100:
DATE: JAN 19 2006

Time: 5:57:03 PM Operator: JB

COLOR: CMYK

CI.I, Div. 2, Groups A,B,C,D
CI.I, Zone 2 Aex nA II
CI.II, Division 2, Groups F,G
Enclosure Type 4X

nLLK Series Nonmetallic
Flourescent Luminaires

TCP: 15001

Typedriver Name: TS name csm no.: 100

Wet Locations
UL and cUL Listed
ATEX Certified

6L

The Cooper Crouse-Hinds SpecOne TM nLLK Series Fluorescent
Luminaire is an ideal source of general illumination indoors or out, in
ordinary or hazardous environments. Its heavy-duty, nonmetallic
construction stands up to tough physical and environmental
demands, making it an excellent choice where dust, dirt, gas, vapor,
smoke, fumes, moisture, corrosive and wet conditions are present. As
with all SpecOne products, the nLLK luminaire meets the standards
and codes of regulating agencies throughout the world, which
simplifies product specifying for multinational users.

APPLICATIONS
nLLK series luminaires are used:
In indoor or outdoor, ordinary or
hazardous areas
Where a heavy-duty, nonmetallic luminaire
is required to hold up to tough physical
and environmental demands including
corrosives, water, dust and extreme
temperatures
ɀ manufacturing plants
ɀ heavy industrial facilities
ɀ industrial process facilities
ɀ refineries
ɀ chemical
ɀ petrochemical
ɀ pharmaceutical
ɀ waste water and sewage treatment plants
In areas where low mounting height,
immediate full illumination, and the even
light distribution associated with a linetype
light source are required
ɀ loading docks
ɀ tunnels
ɀ stairways
Where wet location or Type 4X protection
is required
ɀ dock areas
ɀ production platforms
In hosedown areas where cleanliness and
sanitation are prime factors
ɀ dairies
ɀ canneries
ɀ food processing plants
ɀ bottling plants
ɀ laboratories

CERTIFICATIONS &
COMPLIANCES
NEC
ɀ Class I, Division 2, Groups A, B, C, D
ɀ Class I, Zone 2 AEx nA II
ɀ Class II, Division 2, Groups F, G
ɀ Wet Locations
ɀ UL Listed
CEC
ɀ Class I, Zone 2 Ex nA II
ɀ Class I, Division 2, Groups A, B, C, D
ɀ Class II, Division I, Groups E, F, G
ɀ cUL Listed (certified by UL)
Enclosure
ɀ Type 4X
ɀ IP65
UL Standards
ɀ 2279 Hazardous (Zones Classified)
Locations
ɀ 1598 Luminaires
CSA Standards
ɀ C22.2 No. 9
ɀ CAN/CSA–E79-15

STIBOINFO((CRH:66008com:6L:849))

ɀ one-piece housing—fiber-glass reinforced
polyester
ɀ lens—polycarbonate
ɀ gasket—silicone

STANDARD FINISHES
ɀ fiberglass housing—natural (white)
ɀ lens—natural (clear)

RATINGS (ELECTRICAL/
SIZE)
Sources/Wattages
ɀ two 17 W or two 32 W linear fluorescent
Voltages
ɀ 120–277 V, 50–60 Hz.
ɀ 347 V, 60 Hz.—consult factory
Hub Size
ɀ four 25 mm entries, two on each end, three
plugged
ɀ two Myers® STM2 25 mm to 3⁄4⍯ NPT
adapter hubs provided standardfor throughfeed or tandem wiring

ATEX
ɀ ATEX Directive 94/9/EC
ɀ Type of Protection
ɀ EC-Type Examination
Certificate
ɀ EC-Type Examination
Certificate

US: 1-866-764-5454

CH0 5 L - 3 0

STANDARD MATERIALS

CAN: 1-800-265-0502

II 3 G
II 2 D/II 3 D T80°C
EEx nA II T4 nach EN 50021
PTB 96 ATEX 2208
DMT 02 ATEX E116

Copyright© 2006 Cooper Crouse-Hinds

849

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0850-23 Name: 6L-850

6L

DATE: JAN 19 2006

Time: 5:57:04 PM Operator: JB

COLOR: CMYK

TCP: 15001

CI.I, Div. 2, Groups A,B,C,D
CI.I, Zone 2 Aex nA II
CI.II, Division 2, Groups F,G
Enclosure Type 4X

nLLK Series Nonmetallic
Flourescent Luminaires

Typedriver Name: TS name csm no.: 100

Wet Locations
UL and cUL Listed

IP65, Type 4X heavy-duty construction
ɀ nonmetallic body, gasketed lens and
unique labyrinth lens locking system
ɀ dust-tight, water-tight and moisture-tight
ɀ corrosion and impact-resistant
ɀ ideal for outdoor applications
Electronic ballast
ɀ lower ambient temperatures suitability to
-18°C
ɀ high–power factor ballast (+90%) allows for
more luminaires per circuit
Standard T8 bi-pin lamps—most common
lamp used; energy-efficient and cost-effective
Removable lens—hinged on both sides for
easy installation and maintenance
Easy wiring and installation—
ɀ four 25 mm entries. Two Myers® 3⁄4⍯ NPT
adapter hubs supplied standard
ɀ suitable for through-feed or tandem
applications
ɀ extra-large wire well eliminates need for
separate junction boxes
Worldwide suitability
ɀ NEC/CEC: Class I, Zone 2 and Division 2
areas
ɀ IEC/CENELEC certified luminaires
available. Consult factory.

ORDERING INFORMATION
HUB SIZE*
3⁄4⍯ NPT
3⁄4⍯ NPT
* 25 mm entries—supplied with two Myers

LAMP DESCRIPTION
17 W T8, Rapid Start—2 lamps
32 W T8, Rapid Start—2 lamps
®

VOLTAGE/HZ.
120–277 V, 60 Hz.
120–277 V, 60 Hz.

CATALOG NO.
nLLK98 2217/UNV
nLLK98 4232/UNV

STM2 25 mm to 3⁄4⍯ NPT adapter hubs.

ACCESSORIES
DESCRIPTION
SW13 hexagon key (for maintenance and lamp replacement)
Myers® 25 mm to 3⁄4⍯ NPT adapter hub

CATALOG NO.
3 2485 000 005
STM2

MOUNTING ACCESSORIES
TYPE
CORROSION PROTECTION
Eyebolt A2
Galvanized
Hexagon Screw S4 (to attach ceiling
mounting bracket or pipe clamp to
Nickel Chromium
luminaire)
Ceiling Mounting Bracket D92
Nickel Chromium
Pipe Clamp R12
Hot Galvanized
Pipe Clamp R14
Nickel Chromium
Pipe Clamp R22
Hot Galvanized
Pipe Clamp R32
Hot Galvanized

850

STIBOINFO((CRH:66008com:6L:850))
CH0 5 L - 3 0

US: 1-866-764-5454

PIPE DIN

11⁄4⍯
11⁄4⍯

11⁄2⍯
2⍯

CAN: 1-800-265-0502

OUTER DIA.

38–42 mm
38–42 mm
47–51 mm
56–60 mm

QTY. PER
LUMINIARE
2

CATALOG NO.
2 2480 002 000

2
2
2
2
2
2

2 2480 054 000
2 2480 092 000
2 2480 462 000
2 2480 464 000
2 2480 472 000
2 2480 482 000

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0851-27 Name: 6L-851

100:
DATE: JAN 19 2006

Time: 5:57:05 PM Operator: JB

COLOR: CMYK

CI.I, Div. 2, Groups A,B,C,D
CI.I, Zone 2 Aex nA II
CI.II, Division 2, Groups F,G
Enclosure Type 4X

nLLK Series Nonmetallic
Flourescent Luminaires

TCP: 15001

Typedriver Name: TS name csm no.: 100

Wet Locations
UL and cUL Listed

6L

PHOTOMETRIC DATA

TEMPERATURE PERFORMANCE
Minimum Starting Temperature: -18°C
WATTS

AMBIENT

CLASS I, DIV. 2
(CLASS I, ZONE 2)

CLASS II, DIV. 1 (CEC)
CLASS II, DIV. 2 (NEC)

SUPPLY WIRE
TEMP °C

Two 17 W T8 lamps
Two 32 W T8 lamps

40°C
40°C

T4
T4

T6
T6

60
60

Eyebolt

MAINTENANCE AND RELAMPING
(eLLK Series Div. 1/Zone 1 luminaire is shown. Maintenance procedures are the same for the nLLK.)

Hexagon Screw

1. One quarter turn with the SW13
hexagon key or a 5⁄16⍯ (M8) Allen hex
head wrench releases multiple locking
points.
2. Lamps can be stored in open lens,
freeing up hands for easy relamping.
3. Replace the bi-pin lamp, lock with
one quarter turn of the wrench for an
IP65, Type 4X seal.

Ceiling Mounting Bracket

DIMENSIONS (mm) & WEIGHT
Weight: 8.8 lbs. (4.0 kg.)—17 W 13.2 lbs. (6.0 kg.)—32 W

Pipe Clamp

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:851))
CH0 5 L - 3 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

851

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0852-23 Name: 6L-852

6L

100:
DATE: JAN 19 2006

Time: 5:57:07 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

CI.I, Div. 2, Groups A,B,C,D
Wet Locations
CI.I, Zone 2 Group IIC
NEMA 3,3R
CI.II, Div. 1, Groups F,G
CI.III & Simultaneous Presence

FVN Series
Flourescent Luminaires

Certifications and Compliances:
NEC and CEC:
ɀ Class I, Division 2 Groups A, B, C & D
ɀ Class I, Zone 2 Groups IIC
ɀ Class II, Division 1 Groups F, G
ɀ Class III
ɀ Simultaneous Presence (Cl. I and Cl. II)
UL Standards:
ɀ 844 Hazardous (Classified) Areas
ɀ 1598 Luminaires
CSA Standards:
ɀ C22.2 NO. 137

FVN Luminaires are ideal for use:
ɀ In areas made hazardous by the abnormal conditions resulting in
the presence of flammable vapors or gases and combustible dusts as
defined by the National Electrical Code®.
ɀ Where broken lamps would damage machinery or processes, or
harm people working in the area.
ɀ In areas where stringent sanitation requirements exist.

Standard Materials:
ɀ Luminaire housing - 20-gauge seamless sheet steel
ɀ Lens/Frame Assembly - stainless steel
ɀ Glass - 3/16” tempered
ɀ Suspension flanges - seamless sheet steel
ɀ Gaskets - silicone
ɀ Lamphoders - white thermoset plastic
ɀ Clamps - stainless steel

Features
ɀ One-piece seamless sheet steel housing with welded end caps
keeps dirt, dust and moisture away from ballast and lamps. Easy to
clean.
ɀ A silicone rubber gasket provides a dust-tight seal between the
lens/frame assembly and housing.
ɀ Lens/frame assembly is hinged and wireway cover is held by safety
chain for ease of lamp replacement and maintenance.
ɀ Polyester powder coat finish provides high reflectance and corrosion
resistance for long life and dependable service.
ɀ Two 1⁄2” NPT pendant hubs and two 1⁄2” NPT thru-feed end hubs are
standard.
ɀ Electronic ballast is standard on 32, 40(/UNV only) and 54 watt
luminaires.
FVN Fluorescent Luminaires with T5 HO lamps offer...
ɀ High lumen output per watt - provides energy savings versus other
higher wattage fluorescent luminaires with similar lumen output.
ɀ Longer lamp life and good lumen maintenance - reduced
maintenance and lamp replacement costs.

Standard Finishes:
ɀ Reflector housings - corrosion resistant white polyester powder coat
ɀ Lens/Frame - natural

Dimensions:

Ordering Information (Lamps not supplied): Supercedes ordering information in Catalog 6000, Section 5L.
Lamp
Watts
32
32
40
40
60
60
60
60

Line
Voltage/Hertz
120-277/50-60
347/60
120-277/50-60
347/60
120/60
277/60
347/60
220/50

Lamp
Type
T8
T8
T12
T12
T12HO
T12HO
T12HO
T12HO

Hub Size
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT

FVN Fluorescent Luminaires with T5 HO Lamps (Lamps not supplied)
54
120-277/50-60
T5HO
1/2 NPT
54
347/60
T5HO
1/2 NPT

852

STIBOINFO((CRH:66008com:6L:852))
CH0 5 L - 3 0

US: 1-866-764-5454

CAN: 1-800-265-0502

2-Lamp Cat. No.
FVN4232TG/UNV
FVN4232TG/347
FVN4240TG/UNV
FVN4240TG/347
FVN4260TG/120
FVN4260TG/277
FVN4260TG/347
FVN4260TG/200-50

3-Lamp Cat. No.
FVN4332TG/UNV
FVN4332TG/347
FVN4340TG/UNV
FVN4340TG/347
—
—
—
—

FVN4254TG/UNV
FVN4254TG/347

—
—

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0853-16 Name: 6L-853

100:
DATE: JAN 19 2006

Time: 5:57:08 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

CI.I, Div. 2, Groups A,B,C,D
Wet Locations
CI.I, Zone 2 Group IIC
NEMA 3,3R
CI.II, Div. 1, Groups F,G
CI.III & Simultaneous Presence

FVN Series
Flourescent Luminaires

6L

Options:
The following special options are available from the factory by adding suffix to luminaire Cat. No.
Description
ɀ Low temperature electromagnetic ballast, 40W rated 0°F (-18°C), 60W rated -20°F (-29°C)
ɀ 45° angle brackets (field installed)
ɀ Adjustable angle brackets (field installed)
ɀ Angle bars for chain suspension (field installed)
ɀ Individually fused balast (internal)
ɀ Emergency lighting battery unit (Class I, Division 2 only). Also available for use with T5 lamps
Supplied with charging indicator light and instructions for use with a remote push-to-test station.
†

Suffix
BY
AG
KH
CX
FB
S799†

If push-to-test operator installed in the luminaire is required, consult factory.

Temperature Performance Data:
(Based on 40°C ambient)
Lamp
32W
40W
54W
60W

Cl. I, Div. 2 & Zone 2
Supply2-Lamp 3-Lamp
T5
T5
T5
T5
T3C
—
T4
—

Class II
2-Lamp
T6
T6
T6
T6

3-Lamp
T6
T6
—
—

Simultaneous Presence
2-Lamp
3-Lamp
T4
T4
T4
T4
T3C/T6
—
T4
—

Supply
Wire
60°C
60°C
75°C
90°C

Photometric Data:
Luminaire with two 54W High Output T5 Linear Fluorescent Lamps
FVN4254

FVN .ies photometric files for use with our Luxicon® Lighting Layout Software are available from the Resources area of our website.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:853))
CH0 5 L - 3 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

853

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0854-3 Name: 6L-854

6L

100:
DATE: JAN 19 2006

Time: 5:57:09 PM Operator: RB

FVN Series
Fluorescent Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

Luminaire: FVN with 2-40W lamps (tempered lens)

Luminaire: FVN with 3-40W lamps (tempered lens)

Lamp: 2-40/T-12
Zonal Degrees: 0-30 0-40 0-60 0-90
Zonal Lumens: 1182 1971 3555 4284
Total Bare Lamp Lumens: 6300
To determine number and placement of luminaires,
see Lighting Selector Guide, pages 665 to 689.

Lamp: 3-40/T-12
Zonal Degrees: 0-30 0-40 0-60 0-90
Zonal Lumens: 1695 2834 5099 6079
Total Bare Lamp Lumens: 9450
To determine number and placement of luminaires,
see Lighting Selector Guide, pages 665 to 689.

NOTE: All data provided
is for 2-lamp 40W RS
cool white luminaires
with tempered glass.
Use 1.37 multiplier for
2-lamp 60W luminaires
with tempered glass.
Use .92 multiplier for
2-lamp 32W luminaires
with tempered glass.

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
1
2
3
50
.721
.643
.575
80
30
.695
.603
.527
10
.673
.569
.489
50
.706
.631
.566
70
30
.683
.594
.520
10
.661
.564
.485
50
.677
.607
.547
50
30
.657
.577
.508
10
.641
.549
.476
50
.650
.586
.528
30
30
.636
.561
.496
10
.621
.538
.468
50
.627
.568
.512
10
30
.614
.544
.484
10
.602
.526
.460
0
0
.589
.512
.447
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
6
7
8
50
.416
.375
.338
80
30
.359
.319
.283
10
.319
.281
.244
50
.409
.370
.333
70
30
.356
.315
.281
10
.316
.278
.244
50
.397
.359
.324
50
30
.350
.309
.277
10
.314
.276
.242
50
.386
.348
.316
30
30
.344
.306
.272
10
.311
.273
.240
50
.376
.341
.308
10
30
.338
.301
.268
10
.308
.271
.239
0
0
.295
.258
.226

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
1
2
3
50
.682
.610
.546
80
30
.658
.572
.501
10
.637
.540
.466
50
.668
.599
.538
70
30
.646
.563
.495
10
.625
.535
.462
50
.640
.576
.520
50
30
.622
.547
.454
10
.606
.521
.433
50
.615
.556
.502
30
30
.601
.532
.472
10
.587
.511
.446
50
.594
.537
.487
10
30
.581
.517
.461
10
.570
.499
.439
0
0
.557
.487
.426
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
6
7
8
50
.396
.357
.322
80
30
.343
.304
.270
10
.305
.268
.234
50
.390
.352
.317
70
30
.340
.301
.268
10
.302
.266
.233
50
.378
.342
.309
50
30
.334
.295
.264
10
.300
.264
.231
50
.368
.332
.301
30
30
.328
.292
.259
10
.298
.261
.230
50
.358
.325
.294
10
30
.322
.288
.256
10
.294
.259
.228
0
0
.283
.247
.217

854

STIBOINFO((CRH:66008com:6L:854))
CH0 0 5 L - 7

NOTE: All data provided
is for 2-lamp 40W RS
cool white luminaires
with tempered glass.
Use 1.37 multiplier for
2-lamp 60W luminaires
with tempered glass.
Use .92 multiplier for
2-lamp 32W luminaires
with tempered glass.

4
.513
.459
.418
.505
.455
.415
.488
.444
.410
.473
.435
.405
.459
.426
.399
.385

5
.461
.404
.362
.452
.399
.359
.439
.392
.357
.426
.384
.353
.414
.378
.349
.336

9
.309
.254
.217
.305
.252
.217
.297
.249
.215
.289
.244
.214
.282
.242
.212
.200

10
.269
.215
.180
.265
.215
.180
.259
.211
.179
.253
.208
.177
.247
.205
.175
.164

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

4
.488
.438
.399
.480
.433
.396
.464
.423
.391
.450
.415
.386
.437
.406
.381
.368

5
.439
.385
.346
.430
.381
.343
.418
.374
.341
.406
.367
.337
.394
.361
.333
.321

9
.294
.242
.207
.290
.240
.207
.282
.237
.206
.276
.233
.204
.269
.231
.202
.192

10
.256
.205
.172
.252
.205
.172
.247
.201
.171
.241
.199
.169
.235
.196
.168
.157

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0855-27 Name: 6L-855

100:
DATE: JAN 19 2006

eLLB20 Series
Recessed Mount
Fluorescent Luminaires

Time: 5:57:10 PM Operator: RB

Class I, Div.2, Groups A,B,C,D
Class I, Zone 1, Groups IIC
ATEX Certified

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. II, Div 2, Groups F,G
Cl. II, Div 1, Groups E,F,G (Canada)
Wet Locations
Enclosure Type 4X and IP66

Features & Benefits:

Applications:

ɀ One piece welded housing with fitted cover
frame. The cover frame is an integral part of
the housing to seal out dust & moisture.
ɀ Adjustable mounting clamps:
- permanently attached and adjustable
through the cover frame for easy
installation.
- allow recess mounting in ceilings from
25mm to 100mm (1⍯ to 4⍯ approx) thick for
maximum mounting flexibility.
ɀ Support lugs (M8 x .6) to secure the
luminaire to ceiling structural support
members for safety.
ɀ Frameless tempered glass lens:
- 6mm (1⁄4⍯) thick for added safety.
- interior hinge for maximum dust shedding.
- fitted with captive screws for ease of lamp
replacement and maintenance.
ɀ Isolating switch turns off power to the
ballast and lamps when the lens is opened
for added safety.
ɀ 4 entries (2 on each end) supplied with (2)
3⁄4” NPT adapter hubs and extra large wire
well for feedthrough and tandem applications
without the need for separate junction boxes.
ɀ Electronic ballast:
- high power factor (95%) for energy
efficiency, more luminaires per circuit and
supply voltage flexibility.
- features 2 channel circuitry for safety - if
one lamp fails the 2nd lamp remains in
operation.
ɀ Uses T8 linear fluorescent lamps for high
efficiency and reduced operating costs.
ɀ 5 wire terminal block and through wiring are
standard for quick and easy balancing of
lighting loads on 3 phase systems.

eLLB series luminaires are used:
ɀ For flush or surface ceiling mounting.
ɀ In cleanroom areas where it is important to
have smooth, flush surfaces.
ɀ Where extreme cleanliness is required as in
pharmaceutical, chemical and electronics
manufacturing facilities, as well as in paint
shops and spray booths.
ɀ For tough environmental conditions
involving corrosives, water, dust and extreme
temperatures.
ɀ In areas that require lamps to reach full
illumination immediately.
ɀ Indoor & outdoor ordinary or hazardous
areas.
ɀ For Wet locations and areas with hose
down / wash down requirements.
Adjustable Mounting Clamps

Hinged Glass Lens

6L

Certifications &
Compliances:
NEC :
ɀ Class I, Division 2, Groups A,B,C,D
ɀ Class I, Zone 1 AEx ed IIC
ɀ Class II, Division 2, Groups F, G
ɀ UL Listed
CEC:
ɀ Class I, Division 2, Groups A,B,C,D
ɀ Class I, Zone 1 Ex eds IIC
ɀ Class II, Division 1 Groups E,F,G
ɀ cUL Listed
Enclosure
ɀ Type 4X
ɀ IP66
UL Standards
ɀ 2279 Hazardous (Classified) Locations
ɀ 1598 Luminaires
CSA Standards
ɀ C22.2 No. 9
ɀ CAN/CSA-E60079-0:02
ɀ CAN/CSA-E60079-1:02
ɀ CAN/CSA-E60079-7
ɀ CAN/CSA-E61241-1-1:02

ATEX
ɀ ATEX Directive
94/9/EC
ɀ Type of Protection
ɀ EC-Type
Examination
Certificate

II 2 G
II 2 D T80°C
EEx ed IIC T4
EEx ed ib IIC T4
(CG-variant)
DMT 02 ATEX E 069

Standard Materials:
ɀ One piece welded housing and cover
frame - sheet steel or stainless steel
ɀ Lens - 6mm (1/4⍯) thick tempered glass
ɀ Gaskets - Silicone
ɀ External hardware - stainless steel

Standard Finishes:
ɀ Sheet steel - White epoxy coat
ɀ Lens - Clear
ɀ Stainless steel - Natural

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:855))
CH0 5 L - 3 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

855

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0856-30 Name: 6L-856

100:
DATE: JAN 19 2006

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Class I, Div.2, Groups A,B,C,D Cl. II, Div 2, Groups F,G
Class I, Zone 1, Groups IIC
Cl. II, Div 1, Groups E,F,G (Canada)
ATEX Certified
Wet Locations
Enclosure Type 4X and IP66

eLLB20 Series

6L

Time: 5:57:13 PM Operator: RB

Recessed Mount
Fluorescent Luminaires

Ratings (Electrical / Size):

Temperature Performance Data:

Sources/Wattages
ɀ Two 32W or 17W T8 Linear Fluorescent
Voltages
ɀ 120-240V, 50-60 Hz.
ɀ 110-230VDC
Hub Size
ɀ Four 25mm entries, 2 on each end, 3
plugged.
ɀ Two 3⁄4” NPT adapter hubs provided
standard, for feed-through or tandem wiring.
Terminals
ɀ 5 wire terminal block, one on each end
(L1, L2, L3, N, Ground)
ɀ Two 6mm2 (#10 AWG) maximum per
terminal

Minimum Starting Temperature: -20°C
Watts
Two 17W T8 lamps
Two 32W T8 lamps

Ambient
Temp.
50°C
50°C

Cl. I, Div. 2
Cl. I, Zone 1 & 2
T4
T4

Class II
T6
T6

Supply
Wire Temp
60°C
60°C

Accessories:
ɀ 3⁄4⍯ NPT adapter hub

STM2

Mounting Accessories:
ɀ Eye Bolt for Support Lugs
ɀ Hexagon Screw for Support Lugs

2 2480 002 000
2 2480 054 000

Ordering Information:
Hub
Size

Wattage/Lamp

3⁄4⍯

NPT

Two 17 Watt T8 Rapid Start

3⁄4⍯

NPT

Two 32 Watt T8 Rapid Start

Voltage/Hz
120-240V, 50-60 Hz
110-230 VDC
120-240V, 50-60 Hz
110-230 VDC

Operating
Current

Catalog Number
Epoxy Coated
Stainless Steel
Steel Enclosure
Enclosure

.18A

eLLB20 2217/U240

eLLB20 2217SS/U240

.34A

eLLB20 4232/U240

eLLB20 4232SS/U240

IEC / CENELEC certified luminaires are available. Consult factory.

Dimensions (Inches) and Weights:

Item
eLLB20 2217
eLLB20 4232

856

STIBOINFO((CRH:66008com:6L:856))
CH0 5 L - 3 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Weight
33 lbs.
48 lbs.

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0857-24 Name: 6L-857

DATE: JAN 19 2006

Time: 5:57:14 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

eLLB20 Series Recessed Mount
Fluorescent Luminaires

6L

Photometric Data:

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 20%
ROOM CAVITY RATIO
EFF.
CEIL.
80°

70°

50°

30°

10°

0°

WALL

1

2

3

4

5

6

7

8

9

10

50°

0.679

0.597

0.528

0.468

0.412

0.368

0.329

0.294

0.263

0.239

30°

0.654

0.556

0.478

0.414

0.355

0.310

0.272

0.239

0.209

0.186

10°

0.631

0.522

0.439

0.372

0.313

0.269

0.233

0.200

0.172

0.151

50°

0.664

0.585

0.518

0.459

0.405

0.632

0.324

0.290

0.259

0.235

30°

0.641

0.547

0.472

0.409

0.351

0.307

0.270

0.237

0.207

0.185

10°

0.621

0.516

0.435

0.369

0.311

0.268

0.232

0.200

0.172

0.151

50°

0.637

0.562

0.499

0.443

0.391

0.350

0.314

0.281

0.252

0.229

30°

0.618

0.531

0.460

0.399

0.344

0.302

0.265

0.233

0.204

0.182

10°

0.601

0.504

0.427

0.364

0.308

0.266

0.230

0.198

0.171

0.150

50°

0.612

0.542

0.482

0.429

0.379

0.339

0.305

0.273

0.245

0.223

30°

0.597

0.515

0.448

0.390

0.337

0.296

0.261

0.229

0.201

0.180

10°

0.583

0.492

0.420

0.360

0.304

0.263

0.228

0.197

0.170

0.149

50°

0.589

0.522

0.465

0.415

0.367

0.329

0.296

0.265

0.238

0.217

30°

0.577

0.501

0.437

0.382

0.330

0.291

0.257

0.226

0.198

0.177

10°

0.566

0.481

0.413

0.355

0.301

0.261

0.257

0.196

0.169

0.149

0°

0.553

0.468

0.400

0.341

0.288

0.248

0.214

0.183

0.156

0.137

* PERCENT REFLECTANCE

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:857))
CH0 5 L - 3 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

857

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0858-7 Name: 6L-858

6L

100:
DATE: JAN 19 2006

Time: 5:57:15 PM Operator: RB

COLOR: CMYK

ɀ

ɀ

ɀ

ɀ

Cl. I, Div 1, Groups C,D
Cl. I, Zone 1 Group IIB
ɀ Cl. II, Div 1, Groups E,F,G
ɀ Cl. III, Simultaneous Presence

EVF Series
Fluorescent
Luminaires

TCP: 15001

Typedriver Name: TS name csm no.: 100

Paint Spray (Suffix S718)
Wet Locations (Suffix S718)
ɀ 3,3R, IP54 (Suffix S718)

Application:
EVF luminaires are used in areas
where hazardous fumes, gases,
or dusts are present.
EVF luminaires with S718 option
are designed specifically for use
inside paint spray booths where
hazardous fumes, gases, and
paint residue are present. This
includes powder paint process
areas.
EVF luminaires with S718 option
are also suitable for use in wet
locations.

Features:
All EVF luminaires
ɀ Provide cool, even light with
natural color rendition
ɀ Reduce relamping schedule
(long lamp life)
ɀ Continuous and uniform
illumination made possible by
mounting end to end (no space
needed between luminaires for
relamping)
ɀ No special tools required for
relamping. Threaded lamp tube
cover provides quick and easy
access for relamping
ɀ Threaded joints on lamp tube
and wiring chamber covers
permit easy access for lower
maintenance costs
ɀ Reflectors can be removed or
replaced with only a screwdriver
ɀ Easy to install. Factory sealed
and wired luminaire facilitates
installation
ɀ Standard electronic ballast for
32 watt and 40 watt rapid start
luminaires.
ɀ Standard energy efficient
ballast for 40 watt slimline, 60
watt and 110 watt luminaires.
ɀ Low temperature ballast is
supplied as standard on 32 watt
T8 (0°F), 40 watt slimline (0°F);
60 watt and 110 watt
luminaires(–20°F).
ɀ All exposed hardware is
stainless steel for maximum
protection against corrosion, and
for longer luminaire life
ɀ Copper-free aluminum
construction throughout means
lighter luminaire weight, easier
installation, and excellent
corrosion resistance
ɀ All exterior materials are nonsparking
ɀ Type P ballasts furnished in
compliance with NEC
ɀ Heavy-duty glass lamp tubes
provide maximum strength and
impact resistance to protect
lamps

858

STIBOINFO((CRH:66008com:6L:858))
CH0 5 L - 2 1

3-lamp

2-lamp with angle reflector

EVF
Furnished For
Hub Line Volts 1-Lamp
2-Lamp
3-Lamp
4-Lamp
Use With
Size 60 Hz.*
Cat. #
Cat. #
Cat. #
Cat. #
3⁄4⍯
32 watt, T-8 medium
120-277
EVF21029/UNV EVF22029/UNV EVF23029/UNV EVF24029/UNV
3⁄4⍯
347
EVF21029/347 EVF22029/347 EVF23029/347 EVF24029/347
Bi-pin 265MA lamps
40 watt, T-12 medium
3/4⍯ 110-125
EVF21082
EVF22082
EVF23082
EVF24082
Bi-pin rapid start
3/4⍯ 277
EVF21087
EVF22087
EVF23087
EVF24087
430MA lamps†
3/4⍯ 347
EVF21089/347 EVF22089/347 EVF23089/347 EVF24089/347
3⁄4⍯
110-125
EVF21032
EVF22032
EVF23032
EVF24032
40 watt, T-12 single
3⁄4⍯
277
EVF21037
EVF22037
EVF23037
EVF24037
pin, slimline
3⁄4⍯
347
EVF21039/347 EVF22039/347 EVF23039/347 EVF24039/347
425MA lamps
EVF21062
EVF22062
EVF23062
EVF24062
60 watt, T-12 recessed 3⁄4⍯ 110-125
EVF21067
EVF22067
EVF23067
EVF24067
contact, 800MA lamps† 3⁄4⍯ 277
3⁄4⍯
347
EVF21069/347 EVF22069/347 EVF23069/347 EVF24069/347
EVF21072
EVF22072
EVF23072
EVF24072
110 watt, T-12 recessed 3⁄4⍯ 110-125
EVF21077
EVF22077
EVF23077
EVF24077
contact, 1500MA lamps† 3⁄4⍯ 277
3⁄4⍯
347
EVF21079/347 EVF22079/347 EVF23079/347 EVF24079/347
* For 220 volt 50 hz, 240 volt 50 hz or 240 volt 60 hz operation change the last ‘‘2’’ in the 120 volt 60 hz catalog number to a ‘‘9’’ and add
‘‘/220 50’’, ‘‘/240 50’’ or ’’/240 60’’ respectively.
ie. For a 2 lamp, 40 watt rapid start luminaire for 220 volt 50 hz operation order an EVF22089/220 50.
† 50 Hz not available.

EVF luminaires with S718
option
ɀ All joints sealed
ɀ Inside paint booth mounting
capabilities provide greater
flexibility in luminaire placement,
avoids necessity of complicated
design and installation work, and
improves task lighting control
ɀ Smooth simple design makes it
easy to remove any accumulated
deposits of paint residue

Mounting
Accessories:
Various hazardous area fittings
are used to mount EVF
luminaires. The fittings shown on
page 859 support the unwired
(relamping) end. For the wired
(ballast) end any of the luminaire
hangers for hazardous locations
(listed in Section 7L) can be
used. CPS conduit outlet bodies
with hub covers (listed in Section
4F) are also suitable

Standard Materials:

Options:
ɀ For suitability for wet locations
and locations having deposits of
readily combustible paint residue
– add Cat. No. Suffix S718
ɀ Corro-free TM epoxy powder
coat – add Cat. No. Suffix S752
ɀ With 45° angle reflectors in lieu
of straight down reflectors – add
Cat. No. Suffix S369
ɀ Clear disposable polyester
tube wrap – consult Cooper
Crouse-Hinds
ɀ Fused – add suffix S658‡
ɀ Furnished with lamps - add
suffix S714.
ɀ Low temperature
electromagnetic ballast for 40
watt T12 rapid start luminaires
rated for 0°F - add suffix BY.

Size Ranges:
ɀ 1, 2, 3, and 4-lamp

Electrical Rating
Ranges:

ɀ Copper-free aluminum except
sheet aluminum reflectors

Standard Finishes:
ɀ Natural except reflectors
ɀ Reflectors – white epoxy
powder coat

Certifications and
Compliances:
ɀ NEC and CEC:
Class I, Division 1 Group C, D
Class I, Zone 1 Group IIB
Class II Group E, F, G
Class III
Simultaneous Presence (Cl. I
and Cl. II)
Paint Spray (S718)
ɀ UL Standards:
844 Hazardous (Classified)
Locations
1598 Luminaires
ɀ CSA Standards:
C22.2 No. 137

ɀ 32 to 110 watts

Temperature Performance Data: (Based on 40°C Ambient)
Lamp
Type
32/40W
60W
110W

1 Lamp
T5
T5
T4

US: 1-866-764-5454

Class I/Class II/Zone 1
2 Lamp
3 Lamp
4 Lamp
T5
T5
T5
T5
T5
T5
T4
T4
T4

CAN: 1-800-265-0502

Supply
Wire
75°C
75°C
90°C

Copyright© 2006 Cooper Crouse-Hinds

‡ When ordering fuses for luminaires,
option S658, you must specify the operating
voltage. S658 cannot be ordered with /MT in
the catalog number.

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0859-2 Name: 6L-859

100:
DATE: JAN 19 2006

Time: 5:57:17 PM Operator: TB

Size
3⁄4

TCP: 15001

Typedriver Name: TS name csm no.: 100

Accessories
Relamping Information

EVF Series
Fluorescent Luminaires

Ceiling Saddle for
Conduit Support

COLOR: CMYK

6L

Relamping Information

Cat. #
EVF20

Ceiling Saddle
for Support Hook
Adjacent ends of two
fixtures suspended in line
close together

Cat. #
EVF021

One cover removed and
lamp partly withdrawn

Where fixtures abut, space for
relamping is obtained by
lowering one end of the tube
assembly as shown. Without
tools, the lamp receptacle
and mounting plate
assemblies can be removed
and the lamp withdrawn. In
inserting, the reverse
procedure is followed.

Support Hook
for Conduit
Size
3⁄4

Cat. #
EVF21

End of one fixture
lowered for relamping

Dimensions
End view

Fixture Type
32 watt, T-8 Bi-pin
40 watt, T-12 Bi-pin
40 watt, T-12 Single pin slimline
60 watt, T-12 Recessed contact
110 watt, T-12 Recessed contact

No. Lamps

⎫
⎭

1 or 2
3 or 4

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:859))
CH0 5 L - 2 2

a
44
461⁄2

b
11
81⁄2

c

d

533⁄8
533⁄8

CAN: 1-800-265-0502

55
55

e
95
100

f
101⁄4
101⁄4

Copyright© 2006 Cooper Crouse-Hinds

1-Lamp
2-Lamp
3-Lamp
4-Lamp

Width
61⁄8
111⁄2
18
241⁄2

859

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

JOB: CRMAIN06-0860-3 Name: 6L-860

6L

100:
DATE: JAN 19 2006

Time: 5:57:18 PM Operator: RB

EVF Series
Fluorescent Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

Luminaire: All 1-Lamp EVF Luminaires

Luminaire: All 2-Lamp EVF Luminaires

Lamp: 1-40/T-12, 1-60/T-12
Zonal Degrees: 0-30 0-40 0-60 0-90
Zonal Lumens: 580 953 1633 1897
Total Bare Lamp Lumens: 3100
To determine number and placement of luminaires,
see Lighting Selector Guide, pages 665 to 689.

Lamp: 2-40/T-12, 2-38/T-12, 2-60/T-12, 2-110/T12
Zonal Degrees: 0-30 0-40 0-60 0-90
Zonal Lumens: 1055 1765 3262 4125
Total Bare Lamp Lumens: 6300
To determine number and placement of luminaires,
see Lighting Selector Guide, pages 665 to 689.

NOTE: All data provided is
for 40W rapid start cool
white lamps. Use following
candlepower/lumen
multipliers for other lamp
sizes: 32W 0.90
40W Slimline 0.84
60W Cool white 1.29
110W Cool white 2.19

NOTE: All data provided is
for 40W rapid start cool
white lamps. Use following
candlepower/lumen
multipliers for other lamp
sizes: 32W 0.90
40W Slimline 0.84
60W Cool white 1.29
110W Cool white 2.19

Example: Zonal lumens of
1-40W lamp for 0-60° is
1633. Zonal lumens of
1-60W lamp for 0-60° is
1633 × 1.29 ⍧ 2107

Example: Zonal lumens of
2-40W lamp for 0-60° is
3262. Zonal lumens of
2-60W lamps for 0-60° is
3262 × 1.29 ⍧ 4208

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
1
2
3
50
.697
.616
.546
80
30
.670
.574
.497
10
.647
.539
.458
50
.682
.604
.538
70
30
.658
.565
.490
10
.635
.534
.454
50
.653
.580
.518
50
30
.633
.549
.478
10
.616
.520
.446
50
.627
.559
.500
30
30
.612
.533
.467
10
.597
.509
.438
50
.605
.539
.484
10
30
.591
.517
.455
10
.579
.498
.431
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
6
7
8
50
.391
.351
.316
80
30
.334
.295
.262
10
.294
.257
.223
50
.384
.346
.312
70
30
.330
.292
.260
10
.290
.255
.222
50
.372
.336
.303
50
30
.324
.286
.255
10
.288
.252
.221
50
.361
.325
.295
30
30
.319
.283
.251
10
.286
.249
.219
50
.351
.318
.287
10
30
.312
.278
.247
10
.283
.248
.218

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
1
2
3
50
.697
.616
.546
80
30
.670
.574
.497
10
.647
.539
.458
50
.682
.604
.538
70
30
.658
.565
.490
10
.635
.534
.454
50
.653
.580
.518
50
30
.633
.549
.478
10
.616
.520
.446
50
.627
.559
.500
30
30
.612
.533
.467
10
.597
.509
.438
50
.605
.539
.484
10
30
.591
.517
.455
10
.579
.498
.431
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
6
7
8
50
.391
.351
.316
80
30
.334
.295
.262
10
.294
.257
.223
50
.384
.346
.312
70
30
.330
.292
.260
10
.290
.255
.222
50
.372
.336
.303
50
30
.324
.286
.255
10
.288
.252
.221
50
.361
.325
.295
30
30
.319
.283
.251
10
.286
.249
.219
50
.351
.318
.287
10
30
.312
.278
.247
10
.283
.248
.218

860

STIBOINFO((CRH:66008com:6L:860))
CH0 5 L - 2 3

98:

4
.485
.430
.388
.477
.426
.385
.460
.416
.380
.445
.407
.375
.431
.397
.370

5
.434
.376
.334
.425
.372
.331
.412
.365
.329
.399
.357
.325
.388
.351
.321

9
.289
.235
.197
.285
.233
.197
.277
.229
.196
.270
.225
.194
.263
.222
.193

10
.252
.198
.164
.248
.198
.164
.242
.195
.162
.236
.192
.161
.230
.189
.159

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

4
.485
.430
.388
.477
.426
.385
.460
.416
.380
.445
.407
.375
.431
.397
.370

5
.434
.376
.334
.425
.372
.331
.412
.365
.329
.399
.357
.325
.388
.351
.321

9
.289
.235
.197
.285
.233
.197
.277
.229
.196
.270
.225
.194
.263
.222
.193

10
.252
.198
.164
.248
.198
.164
.242
.195
.162
.236
.192
.161
.230
.189
.159

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0861-3 Name: 6L-861

100:
DATE: JAN 19 2006

Time: 5:57:19 PM Operator: RB

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

EVF Series
Fluorescent Luminaires

6L

Luminaire: All 3-Lamp EVF Luminaires

Luminaire: All 4-Lamp EVF Luminaires

Lamp: 3-40/T-12, 3-38/T-12, 3-60/T-12, 3-110/T-12
Zonal Degrees: 0-30 0-40 0-60 0-90
Zonal Lumens: 1917 3226 6066 7919
Total Bare Lamp Lumens: 9300
To determine number and placement of luminaires,
see Lighting Selector Guide, pages 665 to 689.

Lamp: 4-40/T-12, 4-38/T-12, 4-60/T-12, 4-110/T-12
Zonal Degrees: 0-30 0-40 0-60 0-90
Zonal Lumens: 1961 3305 6250 8224
Total Bare Lamp Lumens: 12400
To determine number and placement of luminaires,
see Lighting Selector Guide, pages 665 to 689.

NOTE: All data provided is
for 40W rapid start cool
white lamps. Use following
candlepower/lumen
multipliers for other lamp
sizes:
32W 0.90
40W Slimline 0.84
60W Cool white 1.29
110W Cool white 2.19

NOTE: All data provided is
for 40W rapid start cool
white lamps. Use following
candlepower/lumen
multipliers for other lamp
sizes:
32W 0.90
40W Slimline 0.84
60W Cool white 1.29
110W Cool white 2.19

Example: Zonal lumens of
3-40W lamps for 0-40° is
3226. Zonal lumens of
3-40W Slimline lamps for
0-40° is 3226 × 0.84 ⍧
2710

Example: Zonal lumens of
4-40W lamps for 0-30° is
1961. Zonal lumens of
4-110W lamps for 0-30° is
1961 × 2.19 ⍧ 4295

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
1
2
3
50
.712
.626
.553
80
30
.683
.581
.500
10
.658
.544
.459
50
.697
.614
.544
70
30
.670
.572
.494
10
.646
.539
.455
50
.667
.589
.524
50
30
.645
.555
.481
10
.626
.524
.446
50
.640
.567
.505
30
30
.623
.539
.469
10
.607
.513
.439
50
.617
.547
.488
10
30
.602
.523
.457
10
.589
.502
.431
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
6
7
8
50
.392
.352
.317
80
30
.332
.293
.260
10
.290
.254
.219
50
.385
.347
.312
70
30
.329
.290
.258
10
.287
.251
.218
50
.372
.336
.303
50
30
.322
.284
.253
10
.285
.248
.217
50
.362
.325
.295
30
30
.317
.280
.248
10
.282
.245
.215
50
.351
.317
.286
10
30
.310
.276
.244
10
.279
.244
.214

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
1
2
3
50
.692
.607
.535
80
30
.664
.563
.484
10
.639
.526
.442
50
.678
.595
.526
70
30
.652
.554
.477
10
.628
.521
.439
50
.648
.571
.507
50
30
.627
.538
.465
10
.609
.507
.431
50
.622
.550
.488
30
30
.606
.522
.453
10
.590
.497
.423
50
.600
.530
.472
10
30
.585
.506
.442
10
.572
.486
.416
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
6
7
8
50
.379
.340
.306
80
30
.320
.282
.250
10
.278
.243
.210
50
.372
.335
.301
70
30
.316
.279
.248
10
.275
.240
.209
50
.359
.324
.292
50
30
.310
.273
.243
10
.273
.238
.208
50
.349
.313
.284
30
30
.305
.269
.238
10
.271
.235
.206
50
.339
.306
.276
10
30
.298
.265
.235
10
.268
.234
.205

4
.489
.431
.386
.481
.426
.383
.463
.416
.378
.447
.407
.374
.433
.397
.368

5
.436
.376
.331
.427
.371
.328
.414
.364
.326
.400
.356
.322
.388
.350
.318

9
.289
.233
.194
.285
.230
.194
.277
.227
.192
.269
.223
.191
.262
.220
.189

10
.252
.196
.160
.248
.196
.160
.242
.193
.159
.236
.190
.157
.230
.187
.156

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:861))
CH0 5 L - 2 4

COLOR: CMYK

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

4
.473
.416
.372
.465
.411
.369
.447
.401
.364
.432
.392
.360
.418
.383
.354

5
.421
.362
.318
.412
.357
.315
.399
.351
.313
.386
.343
.309
.374
.337
.305

9
.279
.224
.185
.275
.221
.185
.267
.218
.184
.260
.214
.183
.253
.211
.181

10
.243
.189
.153
.239
.189
.153
.233
.185
.152
.227
.182
.150
.221
.179
.149

861

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0862-5 Name: 6L-862

6L

100:
DATE: JAN 19 2006

Time: 5:57:20 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

ɀ Marine & Wet
Cl. I, Div. 1, Groups C,D
Cl. I, Zone 1 Group IIB
Locations
ɀ Cl. II, Div 1, Groups E,F,G
ɀ 3,3R,4,4X: IP66
ɀ Cl. III, Simultaneous Presence

EVFDR Series
Fluorescent
Luminaires

ɀ

Applications:

ɀ EVFDR luminaires are suitable for wet
locations and marine environments, above
and below deck, where hazardous vapors,
gases or dusts are present
ɀ Ideally suited for use on offshore drilling/
production platforms and on shipboard in
hazardous areas
ɀ For mounting where headroom is limited
ɀ For hazardous areas where watertightness
and corrosion resistance are required

Features:

ɀ Exterior surfaces finished with gray epoxy
enamel for corrosion resistance
ɀ Exterior hardware stainless steel
ɀ All joints sealed and gasketed for
watertightness
ɀ Vibration resistant
-shock mounts
-sockets are spring loaded for tight lamp
contact connection
ɀ Heavy duty glass lamp tubes for maximum
strength and impact resistance
ɀ All exterior materials are non-sparking
ɀ C-type beam clamps provide quick and
easy mounting
ɀ Luminaire is adjustable 30° either side of
fixture axis, allowing for control of light output
ɀ Beam clamp support is adjustable allowing
beam clamp to be located to suit structure
ɀ Low profile – luminaire height is 713⁄16⍯ with
standard mounting, 1111⁄16⍯ with shock
mounting option – for maximum clearance
where headroom is critical
ɀ Provides cool light with natural color
rendition
ɀ Continuous and uniform illumination made
possible by mounting end to end (no space
needed between luminaires for relamping) –
see page 859 for relamping information
ɀ Relamping is accomplished without tools.
Quarter-turn fastener allows end of luminaire
to be lowered quickly. Cable supports end of
luminaire while relamping – both hands are
free. Threaded lamp tube cover provides
quick and easy access to lamp and
receptacle
ɀ Reflectors can be removed or replaced with
only a screwdriver
ɀ Ballast housing readily accessible
ɀ Minimum weight – copper-free aluminum
construction throughout
ɀ Type P ballast furnished in compliance with
NEC
ɀ Standard electronic ballast for 32 watt and
40 watt rapid start.
ɀ Standard energy efficient electromagnetic
ballast (40W slimline, 60W and 110W) is
standard.
ɀ Low temperature ballasts are standard on
32WT8, 40W slimline, 60W and 110W. 32 watt
and 40 watt low temperature ballasts are
rated for 0°F. 60 and 100 watt low
temperature ballasts are rated for –20°F.

Standard Materials:

ɀ Housing – copper-free aluminum
ɀ Exposed hardware – stainless steel

862

STIBOINFO((CRH:66008com:6L:862))
CH0 5 L - 2 5

Options:
ɀ Furnished with lamps – add suffix S714 to
Cat. No.
ɀ Furnished with safety cable for high
vibration areas - add suffix S715 to Cat. No.
ɀ Beam clamps with shock mounts are
available for ease of installation and
resistance to vibration – add suffix KIT40 to
Cat. No.
ɀ Beam clamps only – add suffix KIT41 to
Cat. No.
ɀ Low Temperature Electromagnetic Ballast:
40W rapid start rated 0°F - add suffix BY to
Cat. No.
ɀ Emergency lighting battery unit – add suffix
S799 to Cat. No.

Size Ranges:

Certifications and
Compliances:
ɀ NEC and CEC:
Class I, Division 1 Group C,D
Class I, Zone 1 Group IIB
Class II Groups E,F,G
Class III
Simultaneous Presence (Cl. and Cl. II)
ɀ UL Standards
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
ɀ CSA Standards
C22.2 No. 137

Temperature Performance
Data: (Based on 40°C Ambient)

ɀ 2-lamp only

Electrical Rating Ranges:
ɀ 32, 40, 60 and 110W

2-Lamp
32, 40W
60W
110W

Class I
Class II
Zone 1
T5
T5
T4

Supply
Wire
75°C
75°C
90°C

EVFDR
Furnished For
Use With
32 watt, T-8 medium
Bi-pin 265MA lamps
40 watt, T-12 medium
Bi-pin rapid start
430MA lamps†
60 watt, T-12 recessed
contact, 800MA lamps
110 watt, T-12 recessed
contact, 1500MA lamps†

Hub
Size
3⁄4⍯
3⁄4⍯
3/4⍯
3/4
3/4⍯
3/4⍯
3/4⍯
3/4⍯

Line Volts
60 Hz.*
120-277
347
110-125
277

2-Lamp
Cat. #
EVFDR22029/UNV
EVFDR22029/347
EVFDR22082
EVFDR22087

110-125
277
110-125
277

EVFDR22062
EVFDR22067
EVFDR22072
EVFDR22077

* For 220 volt 50 hz, 240 volt 50 hz or 240 volt 60 hz operation change the last ‘‘2’’ in the 120 volt 60 hz catalog number to a ‘‘9’’
and add ‘‘/220 50’’, ‘‘/240 50’’ or ‘‘/240 60’’ respectively.
ie. For a 2 lamp, 40 watt rapid start fixture for 220 volt 50 hz operation order an EVFDR22089/220 50.
† 50 Hz. not available.

Standard Finishes:

ɀ All exterior metal components – gray
epoxy enamel
ɀ Reflectors – white epoxy powder coat

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0863-3 Name: 6L-863

100:
DATE: JAN 19 2006

Time: 5:57:21 PM Operator: RB

COLOR: CMYK

TCP: 15001

Photometric Data and Dimensions

EVFDR Series
Fluorescent Luminaires

Typedriver Name: TS name csm no.: 100

6L

Dimensions

Luminaire: All EVFDR Luminaires
Lamp: 2-40/T-12, 2-60/T-12, 2-110/T-12
Zonal Degrees: 0-30 0-40 0-60 0-90
Zonal Lumens: 1416 2352 4263 5863
Total Bare Lamp Lumens: 8600
To determine number and placement of luminaires,
see Lighting Selector Guide, pages 665 to 689.
NOTE: All data provided is
for two 60 watt, T-12
recessed contact 800MA
cool white lamps
(EVFDR22062). For other
wattages use the following
conversion factors:
32W
.67
40W, Rapid Start
.73
40W, Slimline
.70
110W, Cool White 1.60

Coefficient of Utilization

Example: Zonal lumens for
EVFDR226 fixture, across
the axis, for 40-50° is 1,060.
Zonal lumens for
EVFDR223 fixture, across
the axis, is 40-50° is: 1,060
× .70 ⍧ 742

Effective Floor Cavity Reflectance 20%
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
1
2
3
50
.735
.645
.570
80
30
.700
.594
.512
10
.670
.551
.466
50
.714
.627
.557
70
30
.682
.580
.501
10
.653
.542
.458
50
.673
.593
.528
50
30
.647
.554
.482
10
.624
.520
.444
50
.636
.562
.501
30
30
.616
.530
.463
10
.596
.502
.430
50
.603
.533
.477
10
30
.585
.507
.444
10
.570
.483
.416
0
0
.551
.465
.399
% Reflectance
Room Cavity Ratio
Eff. Ceil.
Wall
6
7
8
50
.408
.368
.332
80
30
.344
.305
.271
10
.298
.262
.228
50
.398
.360
.325
70
30
.338
.299
.267
10
.293
.258
.226
50
.380
.344
.311
50
30
.327
.289
.259
10
.287
.252
.221
50
.364
.328
.299
30
30
.317
.282
.251
10
.281
.246
.217
50
.348
.316
.286
10
30
.306
.274
.244
10
.274
.241
.213
0
0
.259
.226
.198

4
.506
.442
.394
.494
.435
.388
.468
.418
.378
.446
.403
.368
.425
.388
.358
.340

5
.452
.387
.339
.440
.380
.334
.420
.368
.327
.401
.354
.319
.383
.343
.311
.294

9
.304
.243
.202
.297
.240
.201
.285
.233
.197
.274
.226
.193
.263
.220
.189
.175

10
.266
.207
.169
.260
.206
.168
.250
.199
.164
.240
.193
.160
.231
.188
.157
.144

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6L:863))
CH0 5 L - 2 6

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

863

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0864-1 Name: Note Page-864

DATE: JAN 19 2006

Time: 5:57:22 PM Operator: JB

COLOR: CMYK

Notes Page

864

STIBOINFO((CRH:66008com::864))
CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0865-5 Name: 7L-865

100:
DATE: JAN 19 2006

Time: 5:57:23 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Champ-Pak TM Wall Pack &
Floodlight Luminaires
Hazardous and Non-Hazardous

7L

Description

Page No.

Application/Selection

866

Floodlights
Luminaires
Champ-Pak®
CPMV

867-873

H.I.D.
Voyager nR TM Stainless Steel Series
F2MV Champ® Series
FMV Champ® Series
FMV High Wattage Champ® Series
EVMA S812 Hazard ȿ Gard with Trunnion Arm
FZD Series

874-876
877-879
880-882
883-885
890
887-889

Incandescent
RCDE Series

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:865))
CH0 0 0 0 7 L

CAN: 1-800-265-0502

891, 892

Copyright© 2006 Cooper Crouse-Hinds

865

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0866-4 Name: 7L-866

7L

DATE: JAN 19 2006

Time: 5:57:23 PM Operator: RB

Application:

Table 500-3(d)
Identification Numbers.
Maximum
Temperature
Deg. C
Deg. F
450
842
300
572
280
536
260
500
230
446
215
419
200
392
180
356
165
329
160
320
135
275
120
248
100
212
85
185

Identification
Number
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

TCP: 15001

Typedriver Name: TS name csm no.: 100

Application and Selection
Quick Selector Chart

Champ-Pak TM Wall Pack &
Floodlight Luminaires

ɀ General illumination of hazardous and
non-hazardous areas

COLOR: CMYK

Considerations for
Selection:
Environmental:
ɀ What is the hazardous area classification
(NEC ®/CEC) of the location in which the
luminaires will be installed?
Lighting levels required:
ɀ What wattage luminaire(s) will provide the
desired light levels? See Lighting Selector
Guide, pages 665 to 689, to determine
number and location of luminaires required.
Physical arrangement:
ɀ Type of luminaire mounting required,
threaded hub or mounting feet.

Quick Selector Chart

Luminaire

NEC Hazardous
Area
Compliance

Lamp Size
(Watts)

Lamp
Base

CPMV

Cl. I, Division 2

50-150 HID

Mogul

EVMA-S812

Cl. I, Groups C, D
Cl. I, Groups B (suffix GB), C & D

50–400 HID

Mogul

Cl. I, Division 2
Cl. I, Zone 2

150-400 HID

Mogul

F2MV, FMV, FMV High Wattage

Cl. I, Division 2

70-1500 HID

Mogul

FZD

Cl. I, Division 1
Groups B, C, D

150-400 HID

Mogul

RCDE-6

Cl. I, Groups C, D
Cl. I, Group D

150 Incandescent
300 Incandescent

Medium

RCDE-10

Cl. I, Group D

500 Incandescent

Extended Mogul End Prong

VOYAGER nR (SSFMV)

866

STIBOINFO((CRH:66008com:7L:866))
CH0 0 7 L - 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0867-14 Name: 7L-867

100:
DATE: JAN 19 2006

Champ-Pak TM Wall Pack
Luminaires

Time: 5:57:24 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 2, Groups A,B,C,D
Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2 (Suffix S826TB)
Cl. II, Groups F & G
Cl. III & Simultaneous Presence
Marine & Wet Locations ɀ Enclosure Type 4X, IP66

7L

The first low-profile wall pack designed
specifically for hazardous areas.
The Cooper Crouse-Hinds® Champ-Pak TM wall pack luminaire is ideal
for low-profile mounting in hazardous and industrial environments. In
fact, it is suitable for any area with adverse conditions such as
dust, dirt, moisture, vibration, high-pressure hosedowns and high
thermal ambients. Its precisely designed glass refractor minimizes
fixture depth while providing uniform, glare-free illumination.
ɀ Unique compact shallow-profile design mounts virtually anywhere.
ɀ Side-hinged cover with two-screw closing for easy installation and
maintenance.
ɀ Gray Corro-free TM epoxy powder-coated two-piece housing provides
superior corrosion resistance.
ɀ Unique stainless steel wire guard accessory attaches without any
additional hardware for easy installation and maintenance.
ɀ Glass refractor provides uniform light distribution to eliminate glare.
ɀ Vertical lamp design provides even lamp heat distribution for cooler
operation, providing expanded hazardous area suitability.
ɀ Silicone gaskets make luminaire suitable for enclosure Type 4X,
Marine and IP66 environments.
ɀ Available in two different conduit entry configurations to permit
flexible installation and mounting.
ɀ four 3⁄4⍯ NPT hubs, one on each side
ɀ two 1⁄2⍯ NPT hubs on bottom for feed-through applications

APPLICATIONS

ADDITIONAL FEATURES & BENEFITS

ɀ indoor and outdoor wall mounting or
vertical surface mounting where minimal
fixture depth is required in:
ɀ manufacturing plants and heavy industrial
facilities
ɀ industrial process facilities such as
refineries, chemical, petrochemical,
pharmaceutical, and production platforms
ɀ waste or sewage treatment plants
ɀ offshore, dockside and harbor
installations
ɀ for security and safety lighting in industrial
facilities
ɀ for lighting of loading docks, tunnels and
stairways
ɀ for marine, wet location, hosedown and
corrosive environments

ɀ Variety of lamp types and wattages—HID,
fluorescent and induction—to meet specific
lighting needs.
ɀ High-power-factor ballasts (+90%) are
standard, which allow more luminaires per
circuit.
ɀ Up to 65°C ambient suitability on select
lamp types and wattages. Ambient suitability
of +40°C is standard. Allows for installation in
higher ambient environments commonly
found in industrial facilities.
ɀ Low ambient starting capability (to
-40°C)—perfect for colder climates.
ɀ Shock-absorbing HID mogul base lamp
socket cushions lamp, improves lamp life in
harsh environments.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:867))
CH0 0 4 F - 5

CAN: 1-800-265-0502

ɀ Compact fluorescent emergency luminaire
provides 90 minutes of lighting during power
outages, meeting UL924 and life safety code.
ɀ Cost-effective induction lamp system
provides extra-long lamp life—up to 100,000
hours. Reaches full illumination immediately,
providing crisp white light.
ɀ NEC/CEC Restricted Breathing
construction is available to provide cooler
temperature classes (T codes) for expanded
hazardous area suitability.
ɀ Simplified method for compliance to NEC
Restricted Breathing conduit sealing
requirements makes installation easier.

Copyright© 2006 Cooper Crouse-Hinds

867

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0868-12 Name: 7L-868

7L

DATE: JAN 19 2006

Time: 5:57:25 PM Operator: RB

Champ-Pak TM Wall Pack
Luminaires

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 2, Groups A,B,C,D
Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2 (Suffix S826TB)
Cl. II, Groups F & G
Cl. III & Simultaneous Presence
Marine & Wet Locations ɀ Enclosure Type 4X, IP66

STANDARD MATERIALS

RATINGS (ELECTRICAL/SIZE)

ɀ fixture housing and door frame assembly—copper-free aluminum
ɀ external hardware—stainless steel
ɀ refractor lens—borosilicate glass
ɀ gasket—silicone
ɀ reflector—aluminum light sheet
ɀ wire guard—stainless steel

Sources/Wattages

STANDARD FINISHES
ɀ aluminum—Corro-free TM epoxy powder coat
ɀ stainless steel—natural

ɀ high-pressure sodium (HPS)—mogul
base
ɀ metal halide (MH)—mogul base
ɀ mercury vapor (MV)—mogul base
ɀ compact fluorescent
ɀ emergency fluorescent
ɀ induction

50, 70, 100 & 150
70, 100 & 150
100
26, 32, 42, 52, 64 & 84
26
55 & 85

Voltages

CERTIFICATIONS & COMPLIANCES
Luminaires For Use With ANSI Lamps (Mogul Base)
ɀ UL/cUL Listed
ɀ NEC and CEC Class I, Division 2 and Class I, Zone 2
ɀ Restricted Breathing Class I, Division 2 and Zone 2 (suffix S826)
ɀ Class II, Groups F and G
ɀ Class III
ɀ Simultaneous Presence
ɀ Certified for IEC Zone 2 (suffix S826TB)
ɀ Wet Locations; Marine Locations; Enclosure Type 4X; IP66

UL Standards
ɀ 844—hazardous (divisions classified) locations
ɀ 2279—hazardous (zones classified) locations
ɀ 1598—luminaires
ɀ 1598A—luminaires for marine vessels
ɀ 924—emergency lighting (fluorescent emergency luminaire)

CSA Standards
ɀ C22.2 No. 9 and 137
ɀ CAN/CSA-E60079-15:02

HID STANDARD-VOLTAGE BALLASTS
ɀ Dual tap (120 & 277 V, 60 Hz—for 50 W HPS only)—
prewired at 277 V
ɀ Multitap (120, 208, 240 & 277 V, 60 Hz)—prewired at 277 V
ɀ Tritap (120, 277 & 347 V, 60 Hz)—prewired at 347 V
ɀ 120 V, 60 Hz
ɀ 480 V, 60 Hz
FLUORESCENT STANDARD-VOLTAGE BALLASTS
ɀ 120–277 V, 50–60 Hz
ɀ 120 V, 50 Hz (for Canada only)
ɀ 347 V, 60 Hz (for Canada only)
INDUCTION STANDARD-VOLTAGE BALLASTS
ɀ 120 V, 50–60 Hz (also 120 V DC)
ɀ 230 V, 50–60 Hz (also 240 V DC)
HID OPTIONAL VOLTAGE BALLASTS
ɀ 220 V, 50 Hz
ɀ 220 V, 60 Hz
ɀ 240 V, 50 Hz
FLUORESCENT OPTIONAL VOLTAGE BALLASTS (Consult Factory)
ɀ 125 V DC
ɀ 12 V DC
ɀ 24 V DC

IEC Standards
ɀ 60079-15

ISOLATED BALLASTS AND SPECIALS (Consult Factory)
ɀ 208 V, 60 Hz CWI Isolated Ballast
ɀ 240 V, 60 Hz CWI Isolated Ballast
ɀ 480 V, 60 Hz CWI Isolated Ballast

Conduit Entries
ɀ four 3⁄4⍯ NPT entries, one on each side, top and bottom
(3 plugged)
ɀ two 1⁄2⍯ NPT entries on bottom for feed-through (1 plugged)
ɀ metric entries—consult factory

868

STIBOINFO((CRH:66008com:7L:868))
CH0 0 4 F - 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0869-18 Name: 7L-869

DATE: JAN 19 2006

Time: 5:57:26 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 2, Groups A,B,C,D
Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2 (Suffix S826TB)
Cl. II, Groups F & G
Cl. III & Simultaneous Presence
Marine & Wet Locations ɀ Enclosure Type 4X, IP66

Champ-Pak TM Wall Pack
Luminaires

7L

ORDERING INFORMATION
To complete Catalog Number, add Voltage and Option suffix(es).

HID Luminaires

Fluorescent Luminaires
CATALOG NUMBER
FOR USE WITH
ANSI LAMPS

LAMP
WATTS

HUB SIZE

HIGH-PRESSURE SODIUM
Four 3⁄4⍯ NPT (one each side)
50
Two 1⁄2⍯ NPT (on bottom)
Four 3⁄4⍯ NPT (one each side)
70
Two 1⁄2⍯ NPT (on bottom)
Four 3⁄4⍯ NPT (one each side)
100
Two 1⁄2⍯ NPT (on bottom)
Four 3⁄4⍯ NPT (one each side) 150 (for 55 V lamp)
Two 1⁄2⍯ NPT (on bottom)
METAL HALIDE
Four 3⁄4⍯ NPT (one each side)
Two 1⁄2⍯ NPT (on bottom)
Four 3⁄4⍯ NPT (one each side)
Two 1⁄2⍯ NPT (on bottom)

CPMVS2W050
CPMVS1W050
CPMVS2W070
CPMVS1W070
CPMVS2W100
CPMVS1W100
CPMVS2W150
CPMVS1W150

70

CPMVM2W070
CPMVM1W070
CPMVM2W100
CPMVM1W100

100

METAL HALIDE—PULSE START
Four 3⁄4⍯ NPT (one each side)
Two 1⁄2⍯ NPT (on bottom)

150

MERCURY VAPOR
Four 3⁄4⍯ NPT (one each side)
Two 1⁄2⍯ NPT (on bottom)

100

CPMVM2W150-S828
CPMVM1W150-S828
CPMVC2W100
CPMVC1W100

VOLTAGE SUFFIXES
NEC (UL)
Voltage (60 Hz)
Dual Tap
Multitap
Suffix
/DT
/MT
CEC (CSA/cUL)
Voltage (60 Hz)
Dual Tap
Tritap
Suffix
/DT
/TT
50 W HPS is available only with suffix /DT.

120
/120

480
/480

120
/120

Induction Luminaires With Lamp
(100,000 hours)
LAMP
WATTS

HUB SIZE
Four 3⁄4⍯ NPT (one each side)
Two 1⁄2⍯ NPT (on bottom)
Four 3⁄4⍯ NPT (one each side)
Two 1⁄2⍯ NPT (on bottom)

55
85

Suffix

CATALOG NUMBER
CPMVIG2W055
CPMVIG1W055
CPMVIG2W085
CPMVIG1W085

120 V (also 120 V DC) 230 V (also 240 V DC)
(50–60 Hz)
(50–60 Hz)
/120
/230

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:869))
CH0 0 4 F - 5

3⁄4⍯

NPT (one each side)
Four
Two 1⁄2⍯ NPT (on bottom)
Four 3⁄4⍯ NPT (one each side)
Two 1⁄2⍯ NPT (on bottom)
Four 3⁄4⍯ NPT (one each side)
Two 1⁄2⍯ NPT (on bottom)
Four 3⁄4⍯ NPT (one each side)
Two 1⁄2⍯ NPT (on bottom)
Four 3⁄4⍯ NPT (one each side)
Two 1⁄2⍯ NPT (on bottom)
Four 3⁄4⍯ NPT (one each side)
Two 1⁄2⍯ NPT (on bottom)

26 (one 26 W lamp)
32 (one 32 W lamp)
42 (one 42 W lamp)
52 (two 26 W lamps)
64 (two 32 W lamps)
84 (two 42 W lamps)

CATALOG NUMBER
CPMVF2W026
CPMVF1W026
CPMVF2W032
CPMVF1W032
CPMVF2W042
CPMVF1W042
CPMVF2W052
CPMVF1W052
CPMVF2W064
CPMVF1W064
CPMVF2W084
CPMVF1W084

VOLTAGE SUFFIXES
Voltage
Suffix

NEC/CEC (UL, CSA, cUL)
120–277 V
(50–60 Hz)
/UNV

CEC (CSA, cUL)
347 V
(60 Hz)
/347

Fluorescent Emergency Luminaires
—Continuous Operation
HUB SIZE
Four 3⁄4⍯ NPT (one each side)
Two 1⁄2⍯ NPT (on bottom)

LAMP
WATTS
26 (one 26 W lamp)

CATALOG
NUMBER
CPMVFB2W026
CPMVFB1W026

VOLTAGE SUFFIXES
Voltage
Suffix

NEC (UL)
120–277 V
(50–60 Hz)
/UNV

CEC (CSA, cUL)
120 V
347 V
(60 Hz)
(60 Hz)
/120 CAN
/347

Compelling reasons to choose the new Champ Induction
luminaire as the light source for industrial and hazardous
locations include:

VOLTAGE SUFFIXES
Voltage

LAMP
WATTS

HUB SIZE

CAN: 1-800-265-0502

ɀ Crisp white light (80+ color rendering index) provides increased
safety by clearly illuminating signs, instrument panels, equipment and
more with vibrant natural colors.
ɀ Up to 100,000 hours of lamp life minimizes routine maintenance
costs. If you operate this luminaire for 24 hours, 7 days a week, you
will not need to change the lamp for up to 11 years!
ɀ Instant illumination — no waiting for lamp warm-up time. Increases
productivity and safety.
ɀ Delivers the best possible luminaire temperature rating — T6 (85°C)
when used with the Champ restricted breathing option. Ideal for
hazardous areas where a low ignition temperature is required.
ɀ Starts in low temperatures — as low as -40°C.

Copyright© 2006 Cooper Crouse-Hinds

869

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0870-17 Name: 7L-870

7L

100:
DATE: JAN 19 2006

Time: 5:57:27 PM Operator: RB

Champ-Pak TM Wall Pack
Luminaires

COLOR: CMYK

TCP: 15001

Cl. I, Div. 2, Groups A,B,C,D
Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2 (Suffix S826TB)
Cl. II, Groups F & G
Cl. III & Simultaneous Presence
Marine & Wet Locations ɀ Enclosure Type 4X, IP66
SUFFIX TO ADD TO

SUFFIX TO ADD TO

OPTIONS

CATALOG NUMBER

BALLAST-GARD TM STARTER CUT-OUT
SWITCH
ɀ prevents starter pulsing when lamp is cycling
or inoperative; prolongs ballast and ignitor life
ɀ available for use with HPS only
ɀ not available with IR or QTZ options
FACTORY ASSEMBLED WITH LAMP INSTALLED
INSTANT RESTRIKE
ɀ enables a hot HPS lamp to immediately restrike
after a momentary loss of arc due to voltage
fluctuation or power outage; it has no effect on
the warm-up period of cold lamps
ɀ available for use with HPS only
ɀ not available with BG or QTZ options
GUARD—FACTORY INSTALLED ON LUMINAIRE
(Guard suffix follows wattage designation, e.g.,
CPMVS2W100P/MT)
QUARTZ AUXILIARY
ɀ quartz auxiliary lighting comes to full brightness
immediately and remains lit until the HID lamp
attains 60–70% of full illumination
ɀ available for use with HID only
ɀ for nonhazardous locations only
ɀ quartz lamp not furnished—use 100 W singleended lamp Q100DC, Q100DL/DC or
100Q/CL/DC
FUSED
ɀ protects ballast and capacitors against
abnormal line conditions (not for use in Canada
or marine locations)
ɀ not available with CPMVIG and CPMVFB
luminaires
RESTRICTED BREATHING CONSTRUCTION
(AEx nR, Ex nR)
Suitable for NEC/CEC Class I, Division 2 and Zone 2
ɀ provides cooler temperature classes (T codes)
ɀ furnished with P55 guard

BG

FA
IR

P

QTZ

S658*

OPTIONS

V2PC PHOTOCELL—
FACTORY INSTALLED
ɀ 120 V, 50–60 Hz
ɀ 208–240 V, 50–60 Hz
ɀ 277 V, 50–60 Hz
OPTIONAL VOLTAGE BALLASTS
FOR HID LUMINAIRES
ɀ 220 V, 50 Hz
ɀ 220 V, 60 Hz
ɀ 240 V, 50 Hz

S826

/208CWI
/240CWI
/480CWI

PHOTOCELL FOR FIELD INSTALLATION
ɀ 120 V, 50–60 Hz
ɀ 208–240 V, 50–60 Hz
ɀ 277 V, 50–60 Hz
In Canada, use factory-installed photocell only.

NOTE: Approximate weight less guard 28 lbs.
P55 guard 0.5 lbs.

STIBOINFO((CRH:66008com:7L:870))

/220 50
/220 60
/240 50

ISOLATED BALLAST FOR
HID LUMINAIRES (Consult Factory)
ɀ 208 V, 60 Hz
ɀ 240 V, 60 Hz
ɀ 480 V, 60 Hz

DIMENSIONS (INCHES)

CH0 0 4 F - 5

/V2PC20
/V2PC22
/V2PC27

/125 VDC
/12 VDC
/24 VDC

STAINLESS STEEL WIRE GUARD

CAN: 1-800-265-0502

S826TB

OPTIONAL VOLTAGE BALLASTS
FOR FLUORESCENT LUMINAIRES
(Consult Factory)
ɀ 125 V DC
ɀ 12 V DC
ɀ 24 V DC

* When ordering fuses for luminaires, option S658, you must specify the operating voltage.
S658 cannot be ordered with /MT in the catalog number.

US: 1-866-764-5454

CATALOG NUMBER

CERTIFIED FOR IEC ZONE 2 (Ex nR)
(UL CLASSIFIED TO THE IEC STANDARD)
Furnished with:
ɀ 4 mm2, 3-point terminal block
ɀ crimp internal wiring connections
ɀ P55 guard

ACCESSORIES
(ORDER SEPARATELY)

TEFLON is a registered trademark of E.I. duPont Co.

870

Typedriver Name: TS name csm no.: 100

Copyright© 2006 Cooper Crouse-Hinds

CATALOG
NUMBER
V2PC20
V2PC22
V2PC27
P55

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0871-33 Name: 7L-871

100:
DATE: JAN 19 2006

Champ-Pak TM Wall Pack
Luminares

Time: 5:57:28 PM Operator: JB

COLOR: CMYK

TCP: 15001

Photometric Data

Typedriver Name: TS name csm no.: 100

7L

CPMV PHOTOMETRIC DATA
LUMINAIRE WITH REFRACTOR LESS WIRE GUARD
CPMVS2W150 Lamp: 150 W/E23-1/2 Clear High Pressure Sodium (HPS)
CANDELAS
Vertical
Angle
0
5
15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180

Front
Side
Back
413
413
413
470
418
367
877
654
265
1343
947
169
1629
1135
126
1614
1369
68
2434
1267
17
2505
1281
0
2084
916
4
1555
322
8
1148
265
11
956
228
8
723
156
9
527
86
9
355
56
8
224
40
4
150
20
1
64
11
1
19
9
3
0
8
1
3
3
3
ZONAL LUMENS
Zone
Lumens
0-10
42
10-20
178
20-30
371
30-40
587
40-50
760
50-60
1095
60-70
1277
70-80
1028
80-90
666
90-100
462
100-110
338
110-120
236
120-130
175
130-140
91
140-150
31
150-160
10
160-170
2
170-180
0
Total
7349

LUMINAIRE WITH REFRACTOR LESS WIRE GUARD
CPMVM2W150-S828 Lamp: 150 W/ED28 Clear Pulse Start Metal Halide
CANDELAS
Vertical
Angle
0
5
15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180

Front
Side
Back
404
404
404
442
424
413
692
549
238
1345
748
136
1475
946
99
1683
1121
56
2105
1095
15
2421
1107
3
2230
924
0
1946
349
0
1612
280
0
1154
231
0
738
164
0
535
97
0
360
55
0
237
39
0
139
22
0
56
12
0
17
8
0
0
8
0
3
3
0
ZONAL LUMENS
Zone
Lumens
0-10
42
10-20
150
20-30
320
30-40
537
40-50
709
50-60
921
60-70
1218
70-80
1153
80-90
829
90-100
492
100-110
347
110-120
242
120-130
167
130-140
113
140-150
35
150-160
10
160-170
2
170-180
0
Total
7287

For additional photometric data, contact Cooper Crouse-Hinds.
US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:871))
CH0 0 4 F - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

871

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0872-9 Name: 7L-872

7L

100:
DATE: JAN 19 2006

Time: 5:57:33 PM Operator: JB

COLOR: CMYK

TCP: 15001

Photometric Data

Champ-Pak TM Wall Pack
Luminaires

LUMINAIRE WITH REFRACTOR LESS WIRE GUARD
CPMVF2W084 Lamps: (2) PL-T 42W/30/4P Compact Fluorescent
CANDELAS
Vertical
Angle
0
5
15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180

Front
258
319
421
516
590
671
720
725
657
566
541
526
409
277
145
97
52
34
8
0
0

Side
258
269
316
361
376
362
347
317
264
195
160
132
86
49
31
21
11
3
1
0
0

Back
258
227
139
58
33
10
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

ZONAL LUMENS
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
Total

Lumens
26
87
155
223
286
334
357
349
309
262
188
113
64
36
16
5
0
0
2810

LUMINAIRE WITH REFRACTOR LESS WIRE GUARD
CPMVIG2W055 Lamp: 55 W Philips Induction Lamp System
CANDELAS
Vertical
Angle
0
5
15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180

Front
241
290
352
414
427
475
462
439
364
330
309
276
206
121
80
55
32
21
5
0
1

Side
241
243
259
268
274
295
306
285
214
124
86
63
38
28
20
18
8
5
2
2
1

Back
241
199
110
45
28
12
3
0
0
1
2
2
2
1
2
1
1
2
0
0
1

ZONAL LUMENS
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
90-100
100-110
110-120
120-130
130-140
140-150
150-160
160-170
170-180
Total

Lumens
23
70
114
154
194
224
228
205
169
130
86
52
34
21
9
3
1
0
1717

For additional photometric data, contact Cooper Crouse-Hinds.

872

STIBOINFO((CRH:66008com:7L:872))
CH0 0 4 F - 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0873-18 Name: 7L-873

DATE: JAN 19 2006

Time: 5:57:39 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Temperature Performance Data

Champ-Pak TM Wall Pack
Luminaires

7L

TEMPERATURE PERFORMANCE DATA

AMBIENT
WATTS
Temp °C
HIGH-PRESSURE SODIUM
50
40
55
65*
70
40
55
65*
100
40
55*
150
40*

CLASS I
DIVISION 2 and ZONE 2
RESTRICTED
BREATHING
STANDARD
AEx nR/Ex nR
PRODUCT
OPTION S826

CLASS II and
CLASS III

T3A
T3A
T3
T3A
T3A
T3
T2C
T2C
T2B

T6
T6
T5
T6
T6
T5
T5
T4
T4

40
55
65*
40
40

T3C
T3C
T3C
T3
T2D

T6
T6
T5
T6
T5

T5
—
—
—
—

MERCURY VAPOR
100
40
55*

T2C
T2B

T5
T4

COMPACT FLUORESCENT
26
40
26 (347 V)
55
40
32
40
55
32 (347 V)
40
42 (120–277 V)
40
42 (347 V)
55
40
52
40
55
64
40
55
84
40

T3B
T3A
T3
T3B
T3A
T3
T3B
T3A
T3
T3
T3
T3
T3
T2C

EMERGENCY FLUORESCENT
26
40*

METAL HALIDE
70

100
150PS (S828)

INDUCTION
55
85

40*
55*
40*

SIMULTANEOUS PRESENCE
CLASS I/CLASS II
(Gas and Dust Present in the Same Area)
RESTRICTED BREATHING
STANDARD
AEx nR/Ex nR
PRODUCT
OPTION S826
Suitable for Class I.
Suitable for Class I, Division 2
Division 2/Class II
or Zone 2 and Class II

T5
T3A/T5
T4A*
T3/T4A*
—
—
T5
T3A/T5
—
—
—
—
Consult Factory for Class II Suitability with
105°C Supply Wire
—
—

T5
T4*
—
T5
—
—

SUPPLY
WIRE
TEMP °C

—

90
105
105
90
105
105
90
105
105

T3C/T5
—
—
—
—

T5
—
—
—
—

90
105
105
90
105

—
—

—
—

—
—

90
105

T6
T6
T6
T6
T6
T6
T6
T6
T6
T6
T6
T6
T6
T6

T6
—
—
T6
—
—
T6
—
—
T6
—
T6
—
—

T3B/T6
—
—
T3B/T6
—
—
T3B/T6
—
—
T3/T6
—
T3/T6
—
—

T6
—
—
T6
—
—
T6
—
—
T6
—
T6
—
—

75
75
75
75
75
75
75
75
75
75
90
75
90
90

T3B

T6

—

—

—

75

T2D
T2D
T2B

T6
T6
T6

T6
—
—

—
—
—

T6
—
—

75
75
75

*Fuses (suffix S658) are not available for indicated light sources and ambient temperatures.
NOTE: Luminaires requiring 105°C supply wire are furnished with 3 ft. of rated wire for external wiring connection

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:873))
CH0 0 4 F - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

873

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0874-8 Name: 7L-874

7L

100:
DATE: JAN 19 2006

Time: 5:58:32 PM Operator: RB

Champ® Voyager nR TM
Stainless Steel Floodlight

COLOR: CMYK

TCP: 15001

Cl. I, Div. 2, Groups A,B,C & D
Cl. I, Zone 2, Group IIC
Enclosure Type 4X
IP66
UL and cUL Listed

Typedriver Name: TS name csm no.: 100

Wet Locations
Marine Locations

At last, a hazardous-area luminaire with complete
stainless steel exterior, low temperature ratings and
standard with the restricted breathing rating (vaportight design).
Cooper Crouse-Hinds® Champ Voyager nR stainless
steel floodlight offers the industry’s coolest temperature.
ratings—so it can operate below the ignition
temperature of vapors and gases in your classified area.
It’s also the only mogul-base Class I, Division 2 and
Zone 2 stainless steel floodlight with restricted breathing
(vapor-tight design) as standard construction.
The Champ Voyager nR Floodlight boasts a wide,
powerful beam to deliver more light to your process or
pathway. Standard terminal blocks and a removable
ballast-component tray bring you the best combination
of easy wiring and simple maintenance in one rugged
package.
This unique combination of features makes the Champ
Voyager nR Floodlight ideal for outdoor, marine,
corrosive, and high temperature locations such as:
ɀ offshore platforms and drilling rigs, ship channels and
refineries
ɀ chemical, petrochemical and pharmaceutical plants,
waste water and sewage treatment plants, pulp and
paper mills
ɀ storage tanks and racks, vehicle and pedestrian
passageways, outdoor process areas and parking areas
And because the Champ Voyager nR Floodlight meets
international standards, you can install it anywhere in
the world.

KEY FEATURES AND BENEFITS
ɀ AEx nR, Ex nR restricted breathing rating is standard—a
hazardous location luminaire with excellent T-3 and T-4 ratings
without additional accessories or options.
ɀ NEMA 7x6 ‘‘butterfly beam’’ floodlight pattern—wide, uniform
and far reaching to reduce the number of luminaires you need
providing excellent luminaire efficiency—more light where
you need it.
ɀ easy wiring—standard terminal block with marked terminals saves
time and eliminates wiring errors.
ɀ removable ballast-component tray—for capacitor, igniter and
terminal block to simplify maintenance and save money.
ɀ 316 stainless steel housing, hinges, door cover and mounting
yoke for marine and wet locations—robust construction suitable for
saltwater and corrosive applications.

Removable ballast
component tray

Easy wiring with standard
terminal blocks

874

STIBOINFO((CRH:66008com:7L:874))
CH0 0 4 F - 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0875-14 Name: 7L-875

DATE: JAN 19 2006

Champ® Voyager nR TM
Stainless Steel Floodlight

Time: 5:58:34 PM Operator: GK COLOR: CMYK

Cl. I, Div. 2, Groups A,B,C & D
Cl. I, Zone 2, Group IIC
Enclosure Type 4X
IP66
UL and cUL Listed

CERTIFICATIONS AND
COMPLIANCES
NEC/CEC
ɀ Class I, Division 2
ɀ Class I, Zone 2
ɀ Wet Locations
ɀ Marine Locations
ɀ Enclosure Type 4X, IP66
ɀ UL Listed
ɀ cUL Listed (Certified by UL to CSA
Standards)
IEC/NEC/CEC
ɀ Class I, Zone 2, Group IIC
ɀ Class I, Division 2, Group A,B,C,D
UL STANDARDS
ɀ 844 — Hazardous (Divisions Classified)
Locations
ɀ 1598 — Luminaires
ɀ 1598A — Supplemental requirements for
luminaires for installation on marine vessels.

TCP: 15001

Typedriver Name: TS name csm no.: 100

Wet Locations
Marine Locations

7L

STANDARD MATERIALS

RATINGS

ɀ Enclosure (housing & lens frame)—316
Stainless Steel
ɀ Lens—heat and impact resistant tempered
glass
ɀ Gaskets—silicone rubber
ɀ Yoke and yoke bracket—316 Stainless
Steel
ɀ Reflector—formed specular (dimpled
glossy surface) aluminum
ɀ Cable gland cord grip and locknut—
polyamide 6, neoprene bushing

SOURCES/WATTAGES
(MOGUL BASE LAMPS)
ɀ High Pressure Sodium (HPS) 150, 250 &
400 watts
ɀ Metal Halide (MH) 175, 250 & 400 watts

STANDARD FINISHES
ɀ 316 Stainless Steel—natural

VOLTAGES
Standard Voltage Ballasts
ɀ Multi-tap (120, 208, 240 & 277 V, 60 Hz)
ɀ 480 V, 60 Hz
ɀ Tri-tap (120, 277, 347 V, 60 Hz)
Optional Voltage Ballasts
ɀ 220 V or 240 V, 50 Hz (for export)
ɀ 220 V, 60 Hz (for export)
Isolated Ballasts (consult Cooper
Crouse-Hinds)
ɀ 208, 240, or 480 V (for Canada)
HUB SIZE
ɀ Standard: 3⁄4⍯ NPT with a 3⁄4⍯ sealing cord
grip installed

CSA STANDARDS
ɀ C22.2 No. 137
ɀ CAN/CSAD9 Series
IEC STANDARDS
ɀ .60079-15

ORDERING INFORMATION

DIMENSIONS

(inches)

To complete catalog number, add voltage and option suffix(es)
Example: SSFMVSY150/MT-76 BG-FA
LAMP TYPE
WATTS
CATALOG NUMBER
High-Pressure Sodium

Metal Halide

150
250
400
175
250
400

SSFMVSY150
SSFMVSY250
SSFMVSY400
SSFMVMY175
SSFMVMY250
SSFMVMY400

VOLTAGE SUFFIXES
VOLTAGE (60 Hz)
Tri-tap (120, 277, 347, 60 Hz)
Multi-tap (120, 208, 240, 277V, 60 Hz)
480 V, 60 Hz

SUFFIX
/TT
/MT
/480

OPTIONAL
VOLTAGES
220 50 Hz
220 60 Hz
240 50 Hz

SUFFIX TO ADD
TO CAT. NO.

OPTIONS
Ballast-Gard TM starter cut-out switch prevents starter pulsing
when lamp is cycling or inoperative. Prolongs ballast and igniter
life 150 W HPS only. Not available with options IR or QTZ

BG

Factory assembled w/HID lamp installed

FA

Instant restrike—150W HPs only. Not available with options BG
or QTZ

IR

Quartz auxiliary (lamp not supplied). For non-hazardous
applications only.
Not available with options BG or IR

QTZ

Fused (not for marine or cUL)

S658

ACCESSORIES (order separately)

LUMINAIRE WEIGHTS
CATALOG NO.

Stainless Steel Slipfitter Adapter

SFA6 SS

Stainless Steel Wall Mount Bracket

SWB6 SS

Standard Slipfitter adapter (cast aluminum, epoxy coat)

SFA6

Standard Wall Mount bracket (cast aluminum, epoxy coat)

SWB6

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:875))
CH0 0 4 F - 5

SUFFIX
/220 50
/220
/240 50

CAN: 1-800-265-0502

LUMINAIRE

HPS

(lbs.)
MH

150W

39

—

175W

—

39

250W

43

41

400W

45

43

Copyright© 2006 Cooper Crouse-Hinds

875

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0876-6 Name: 7L-876

DATE: JAN 19 2006

Time: 5:58:35 PM Operator: RB

Champ® Voyager nR TM
Stainless Steel Floodlight

7L

COLOR: CMYK

TCP: 15001

Cl. I, Div. 2
Cl. I, Zone 2
Enclosure Type 4X
IP66
UL and cUL Listed

Typedriver Name: TS name csm no.: 100

Wet Locations
Marine Locations

PHOTOMETRICS
HPS Wide Beam Reflector

MH Wide Beam Relfector

ISO FOOTCANDLE CHART
Stainless Steel Floodlight 400 W High Pressure Sodium (HPS)
Catalog Number: SSMVSY400/MT
Lamp: 400 W Clear HPS
Lumen Rating: 50,000
Luminaire located at 0,0° Aiming Angle at 45° down from horizontal
For 150 W HPS, multiply footcandles by 0.32.
For 250 W HPS, multiply footcandles by 0.57.
MOUNTING
FOOTCANDLE VALUES FOR
HEIGHT
ISO FOOTCANDLE LINES
A
B
C
D
E
F
10′
40.000 20.000 8.000
4.000
2.000
0.800
15′
17.778 8.889
3.555
1.778
0.889
0.356
20′
10.000 5.000
2.000
1.000
0.500
0.200
25′
6.400
3.200
1.280
0.640
0.320
0.128
30′
4.444
2.222
0.889
0.444
0.222
0.089
35′
3.265
1.633
0.653
0.327
0.163
0.065
40′
2.500
1.250
0.500
0.250
0.125
0.050

ISO FOOTCANDLE CHART
Stainless Steel Floodlight 400 W Metal Halide (MH)
Catalog Number: SSFMVMY400/MT
Lamp: 400 W Clear MH
Lumen Rating: 34,000
Luminaire located at 0,0° Aiming Angle at 45° down from horizontal
For 175 W MH, multiply footcandles by 0.42
For 250 W HPS, multiply footcandles by 0.65
MOUNTING
FOOTCANDLE VALUES FOR
HEIGHT
ISO FOOTCANDLE LINES
A
B
C
D
E
F
10′
20.000 8.000
4.000
2.000
0.800
0.400
15′
8.889
3.555
1.778
0.889
0.356
0.178
20′
5.000
2.000
1.000
0.500
0.200
0.100
25′
3.200
1.280
0.640
0.320
0.128
0.064
30′
2.222
0.889
0.444
0.222
0.089
0.044
35′
1.633
0.653
0.327
0.163
0.065
0.033
40′
1.250
0.500
0.250
0.125
0.050
0.025

TEMPERATURE PERFORMANCE DATA

EFFECTIVE PROJECTED AREA (EPA)

AMBIENT
TEMP.
150 W HPS
250 W HPS
400 W HPS
175 W MH
250 W HPS
400 W MH

DIV. 2
40°C
T1(350°C)
T1(350°C)
T1(400°C)
T1(325°C)
T1(325°C)
T1(325°C)

876

STIBOINFO((CRH:66008com:7L:876))
CH0 0 4 F - 5

DIV. 2
55°C
T1(350°C)
T1(350°C)
—
T1(325°C)
T1(325°C)
—

SUPPLY SUPPLY
ZONE 2 ZONE 2 WIRE 0°C WIRE 0°C
40°C
55°C
(40°C)
(55°C)
T4
T3
90°C
105°C
T4
T3
90°C
105°C
T3
—
90°C
—
T3
T3
90°C
105°C
T3
T3
90°C
105°C
T3
—
105°C
—

US: 1-866-764-5454

CAN: 1-800-265-0502

ɀ For windloading
AIMING ANGLE
0 degrees
30 degrees
60 degrees

ɀ For proper pole selection
EPA
2.15 ft2
1.86 ft2
1.07 ft2

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0877-5 Name: 7L-877

100:
DATE: JAN 19 2006

Time: 5:58:36 PM Operator: RB

ɀ

ɀ

ɀ

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)

50-175W F2MV
Series
Champ® H.I.D.
Luminaires

COLOR: CMYK

Ratings (Electrical/Size):

Champ F2MV floodlights are used:
ɀ on platforms and in refineries, chemical and
petrochemical plants, pharmaceutical plants,
waste water and sewage treatment plants, pulp
and paper mills, and other outdoor as well as
indoor industrial locations.
ɀ to light outdoor industrial applications such as
storage tanks and racks, vehicle and pedestrian
passageways, outdoor process areas, and
parking areas in industrial facilities.
ɀ for security & safety lighting in industrial and
process facilities.
ɀ in high ambient temperatures.
ɀ in marine and wet locations
ɀ in outdoor locations where the damaging
effects of rain, snow, wind, dirt & other
contaminants are present
ɀ in Class I, Division 2 hazardous (classified)
locations as defined by the NEC & CEC
ɀ in Class I, Zone 2 hazardous (classified) areas
as defined by the NEC & CEC
ɀ in Zone 2 hazardous (classified) areas as
defined by the IEC

Sources/Wattage (Mogul Base Lamps)
ɀ High Pressure Sodium (HPS) 50, 70, 100 &
150
ɀ Metal Halide (MH) 70, 100, & 175
ɀ Mercury Vapor (MV) 100 & 175
Voltages
Standard Voltage Ballasts
ɀ Multi-tap (120, 208, 240 & 277 volts 60 Hz)
ɀ Dual tap (120, 277 volts 60 Hz) — 50W HPS
only
ɀ 480 volts 60 Hz
ɀ Tri-tap (120, 277. 347 volts 60 Hz).

ɀ For use with other accessories
ɀ SFA-6 Slip Fitter Adapter
ɀ SWMB-6 Wall Mount Bracket
ɀ Restricted Breathing sealing
compliance

ɀ Severe vibration testing compliance
ɀ UL 844
ɀ 3-Axis Resonance Withstand

Optional Voltage Ballasts (consult
Cooper Crouse-Hinds)
ɀ 220 volt or 240 volt 50 Hz (for export)
ɀ 220 volt 60 Hz (for export)
ɀ Isolated Ballasts 208, 240 or 480 volt (For
Canada)
Hub Sizes
ɀ Standard — (2) 3⁄4⍯ NPT
ɀ Optional — (2) 25mm (M25x1.5)

Benefits
Robust design, Industrial grade construction
Insures wet & marine locations integrity
Easy to install & maintain
Provides specifiers with the right product for the task at
hand.
Most common for industrial applications
Addresses high ambients common at industrial
facilities
Ease of maintenance
Perfect for colder climates
Cushions lamp, improves lamp life in harsh
environments
Meets global supply voltage requirements
Standard construction provides the greatest mounting
flexibility — can be mounted vertically (wall),
horizontally (floor) or any angle in between
Further enhances mounting flexibility
Complies with the NEC sealing requirements for
Class I Zone 2 and Class I Division 2 locations using
the standard wiring method of a Cooper Crouse-Hinds
CGB 294SA connector with 16/3 SO extra hard usage
cord
Exceeds vibration tests as required by UL

Standard Materials:
ɀ Enclosure (housing & lens cover) —
copper-free aluminum
ɀ Cover chain and external hardware —
stainless steel
ɀ Lens — heat & impact resistant glass
ɀ Gaskets — silicone rubber
ɀ Yoke — galvanized steel
ɀ Reflector — diffuse aluminum lighting sheet

Standard Finishes:
Enclosure & Yoke — Corro-free epoxy
powder coat
ɀ Stainless steel — natural

* When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:877))
CH0 0 7 L - 4

CAN: 1-800-265-0502

Typedriver Name: TS name csm no.: 100

Marine & Wet Locations
3, 3R, 4, 4X; IP66

Application:

Key Features
ɀ Copper free aluminum enclosure with
stainless steel hardware
ɀ Continuous silicone gasketing
ɀ Small compact size
ɀ Available in a variety of lamp sources
and wattages
ɀ NEMA 7x6 standard floodlight pattern
with lamp orientation base down
ɀ 40° and 55°C ambient suitability
standard with some wattages (less fuses)
to 65°C
ɀ Stainless steel chain secures cover to
housing
ɀ Low ambient capability to –40°C
ɀ Shock absorbing mogul base lamp
socket
ɀ Variety of system voltages available
ɀ Trunnion (yoke) mount design

TCP: 15001

7L

Certifications and
Compliances:

ɀ NEC/CEC:
Class I Division 2, Groups A, B, C, D
Class I Zone 2
ɀ IEC:
Zone 2 Ex nR IIC
ɀ UL Standards:
844, 2279 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
ɀ CSA Standards:
C22.2 No. 137:
ɀ IEC Standards:
60079-15

Options:

Suffix to be
Description
Added to Cat. No.
BG
ɀ Ballast-Gard
-50-150W HPS only
-Cannot use with options IR or QTZ
ɀ Factory assembled w/HID lamp installedFA
ɀ Instant Restrike
IR
-50-150W HPS only
-Cannot use with options BG or QTZ
ɀ Quartz auxiliary (lamp not supplied) QTZ
-For nonhazardous applications only.
-Cannot use with options BG or IR
ɀ Fused
S658*
ɀ Restricted Breathing, (AEx nR, Ex nR) S826
-For NEC/CEC Class I Zone 2
ɀ Restricted Breathing (Ex nR)
S826TB
for IEC Zone 2. Includes:
-3pt. 4mm squared terminal block
-Crimp internal wiring connections
-For use with dedicated voltages only
-(not DT, MT, TT)
ɀ V2PC Photocell Available
Factory Installed Only
Consult CrouseHinds
Accessories: (Order Separately)
ɀ SFA-6
Slipfitter adapter
ɀ SWB-6
Wall Mount bracket
Description
Suffix to be
added to Cat. No.
ɀ Restricted Breathing Construction
S826
Class I Division 2 & Zone 2 Suitability
Cooler Operating Temperatures
(T-Numbers)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
S826TB
Furnished with
ɀ Terminal Block
ɀ Crimp Terminals
ɀ Dedicated voltage ballasts (no MT, DT
or TT).

Copyright© 2006 Cooper Crouse-Hinds

877

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0878-2 Name: 7L-878

7L

DATE: JAN 19 2006

Time: 5:58:37 PM Operator: JB

COLOR: CMYK

ɀ

ɀ

ɀ

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)

50-175W F2MV
Series
Champ® H.I.D.
Luminaires

TCP: 15001

Marine & Wet Locations
3, 3R, 4, 4X; IP66

Temperature Performance Data

Ordering Information
*To complete Catalog Number, add Voltage and Option suffix(s)
Example: F2MVSY150/MT-BG-FA-S658-S826
Lamp Type

High Pressure
Sodium

Metal Halide

Pulse Start
Metal Halide
Mercury Vapor

Lamp Watts

Base Catalog Number*
with
with
3⁄4⍯ NPT Hub
25MM Hub
F2MVSY050
F2MVS25Y050
F2MVSY070
F2MVS25Y070
F2MVSY100
F2MVS25Y100
F2MVSY150
F2MVS25Y150
F2MVMY070
F2MVM25Y070
F2MVMY100
F2MVM25Y100
F2MVMY175
F2MVM25Y175
F2MVMY150-S828
F2MVMY175-S828
F2MVCY100
F2MVC25Y100
F2MVCY175
F2MVC25Y175

50
70
100
150
70
100
175
150
175
100
175

Voltage Suffixes
Voltage (60Hz)
Suffix

Dual-Tap
(50W HPS)
/DT

Typedriver Name: TS name csm no.: 100

Tri-Tap

Multi-Tap

480

/TT

/MT

/480

Class 1
Non
Restricted
Breathing
Division 2

Restricted
Breathing
(S826TB)
Zone 2

Supply
Wire °C

T3C
T3C
T3B
T3A
T3A
T3
T2D
T2C
n/a
T2A
T2A
T2A

T6
T5
T5
T6
T5
T4
T4
T4
n/a
T4
T4
T3

75
75
75
60
75
85
75
90
n/a
75
85
110

40
55
65
40
55
65
40
55
65**

T3C
T3A
T3A
T2D
T2D
T2C
T2A
T2A
T2

T6
T5
T4
T4
T4
T4
T3
T3
T3

75
75
85
75
75
85
75
85
110

Mercury Vapor
100 Watt
40
55
65
175 Watt
40
55
65**

T2B
T2B
T2A
T2B
T2A
T2A

T4
T4
T4
T3
T3
T3

75
85
90
75
85
110

Lamp Watts

Ambient
Temp °C

High Pressure Sodium
50 Watt
40
55
65
70 Watt
40
55
65
100 Watt
40
55
65
150 Watt
40
55
65**
Metal Halide
70 Watt
100 Watt
175 Watt

*Restricted breathing explosion protection
**Suitable for use in 65°C ambient without optional fuses

Dimensions and Weights:
Aiming Range

Luminaire Weight: 26 lbs.

878

STIBOINFO((CRH:66008com:7L:878))
CH0 0 7 L - 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0879-2 Name: 7L-879

100:
DATE: JAN 19 2006

Time: 5:58:39 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

50-175W F2MV Series

7L

®

Champ H.I.D. Luminaires

Isofootcandle Chart
F2MV 150W High Pressure Sodium
Catalog Number F2MVSY150
Lamp: 150 watt clear high pressure sodium
Lumen rating: 16,000
For 100W high pressure sodium, multiply footcandles by .55
For 70W high pressure sodium, multiply footcandles by .40
For 50W high pressure sodium, multiply footcandles by .24

Isofootcandle Chart
F2MV 175W Metal Halide
Catalog Number F2MVMY175
Lamp: 175 watt clear metal halide
Lumen rating: 14,000
For 100W metal halide, multiply footcandles by .58
For 70W metal halide, multiply footcandles by .37

Footcandle Table
Isofootcandle Chart
F2MV 175W Mercury Vapor
Catalog Number F2MVCY175
Lamp: 175 watt clear mercury vapor
Lumen rating: 8,600
For 100W mercury vapor, multiply footcandles by .49

Mounting
Height
10′
15′
20′
25′
30′

Footcandle Values for
Isofootcandle Lines
A
B
C
8.00
4.00
2.00
3.56
1.78
0.89
2.00
1.00
0.50
1.28
0.64
0.32
0.89
0.44
0.22

D
0.80
0.36
0.20
0.13
0.09

E
0.40
0.18
0.10
0.06
0.04

Effective Projected Area (EPA)
ɀ For windloading
ɀ For proper pole selection
Aiming Angle
EPA
0°
1.6 ft2
30°
1.6 ft2
60°
1.1 ft2

Luminaire located a 0°, 0°
Aiming angle 45°
Note: Luminaire aiming angle limited to 30° past vertical through 60°
before vertical.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:879))
CH0 0 7 L - 6

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

879

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0880-7 Name: 7L-880

7L

100:
DATE: JAN 19 2006

COLOR: CMYK

Series
Champ® H.I.D.
Luminaires

TCP: 15001

ɀ

ɀ

ɀ

ɀ

Cl. I, Div 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div 2
& Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)

150-400W FMV

Application:

Time: 5:58:40 PM Operator: JB

Marine & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

Electrical Rating Ranges:

Champ FMV Floodlights are used:
ɀ in refineries, chemical and petrochemical
plants, waste and sewage treatment plants,
pulp and paper mills, and other outdoor
industrial locations.
ɀ to light outdoor industrial applications such
as storage tanks and racks, vehicle and
pedestrian passageways, outdoor process
areas, and parking areas in industrial
facilities.
ɀ for security and safety lighting in industrial
and process facilities.
ɀ in Class I, Division 2 hazardous (classified)
locations, as defined by the National
Electrical Code.
ɀ in high ambient temperatures
ɀ in wet locations/marine locations
ɀ in outdoor locations where the damaging
effects of rain, snow, wind, dirt, and other
contaminants are present.

Features:

ɀ Available in a wide variety of light sources
and wattages: 70-400 watt high pressure
sodium, 175-400 watt metal halide, and
175-400 watt mercury vapor.
ɀ Multi-tap ballasts are standard, offering a
choice of 120, 208, 240, and 277 volts. 220V
50 Hz, 240V 50 Hz, Tri-Tap (120, 277 and
347) and 480 volt ballasts are also available.
ɀ All luminaires are high power factor for
energy efficient operation and optimal circuit
conductor sizing.
ɀ Three mounting styles – yoke (trunnion),
slipfitter adapter & wall mount bracket – are
available to satisfy all mounting requirements.
ɀ Door frame assembly is hinged and has
captive cover screws for ease of relamping.
ɀ Silicone rubber gaskets are standard,
ensuring long life and reliable environmental
sealing even under adverse conditions.
ɀ All die-cast aluminum components are
provided with powder epoxy finish for
superior corrosion resistance.
ɀ All external hardware is stainless steel for
corrosion resistance and reliability.
ɀ Yoke is aluminum for excellent combination
of strength, corrosion resistance and
durability.
ɀ All FMV Champ floodlights can be easily
adjusted to aim light where it is needed.
ɀ NEMA 7x6 beam spread is ideal for most
industrial floodlighting requirements.
ɀ Includes ballast core handle for convenient
ballast replacement.
ɀ Wing-type ballast insulators protect
personnel during maintenance and
relamping and provide quick and easy
accessibility to internal components.

ɀ 70-150 (HPS), 175, 250, 400 watt
ɀ Multi-tap刁 (120, 208, 240, 277 volts), 480 volts
and 220V, 240V 50 Hz.
ɀ Tri-tap (120, 277, 347 volts)
ɀ NEC/CEC:
Class I, Division 2, Groups A,B,C,D
Class I Zone 2
ɀ IEC:
Zone 2 Ex nR IIC
ɀ UL Standards:
844, 2279 Hazardous (classified) locations
1598 Luminaires
1598A Marine locations
ɀ CSA Standards:
C22.2 No. 137
ɀ IEC Standards:
60079-15

Ordering Information:
(For Voltages, See Note 1)
High Pressure Sodium

Metal Halide

Pulse Start
Metal Halide
Mercury Vapor

Lamp Watts
150 (See Note 2)
250
400
175
250
400
250
320
400
175
250
400

Notes to Ordering Information
1. Catalog numbers shown are for multi-tap ballasts
(120, 208, 240, or 277 volt; wired for 277 volt
operation). 220 V 50 Hz, 240 V 50 Hz, and 480 volts
ballasts also available. To order with other ballasts,
change ‘‘MT’’ in catalog number to appropriate
voltage. Example: FMVSY400/220-50-76. For Tri-tap
ballast (120, 277, 347 volts) change MT to TT.
2. 150 watt HPS luminaires are furnished with ANSI
spec./S55 ballasts for 55 volt lamps.
3. Luminaires are furnished with a 3⁄4⍯ NPT drilled and
tapped entrance.

Accessories
(Order Separately)
Cat. No.
Slipfitter adapter (To be mounted to
yoke mount luminaire) . . . . . . . . . . . . SFA6
(Note: SFA6 fits onto 2⍯ pipe/conduit)
Wall bracket (use with slipfitter adapter
SFA6 for easy wall mounting & increased
adjustability.) . . . . . . . . . . . . . . . . . . . SWB6

Options

Suffix to be
Description
Added to Cat. No.
Fused (not available with IR) . . . . . . . . . . . . S658刁
Quartz auxiliary . . . . . . . . . . . . . . . . . . . . . . . . . QTZ
ɀ Non-hazardous locations only.
ɀ Lamp not furnished
Instant restrike . . . . . . . . . . . . . . . . . . . . . . . . . . . . IR
ɀ Cannot be used with BG or QTZ.
ɀ 50-150W LX HPS only.
Ballast Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG
ɀ Restricted Breathing Construction. . . . . . . S826
Class I Division 2 & Zone 2 Suitability
Cooler Operating Temperatures
(T-Numbers)
ɀ Certified for IEC Zone 2 . . . . . . . . . . . . . S826TB
Furnished with
Terminal Block
Crimp Terminals
Dedicated voltage ballasts (no
MT, DT or TT).
刁 CSA certified luminaires are not available with multi-tap ballasts

* When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with /MT
in the catalog number.

Standard Finishes:

ɀ Die-cast aluminum – epoxy powder coat
ɀ Stainless steel – natural.

STIBOINFO((CRH:66008com:7L:880))

US: 1-866-764-5454

Yoke Mount
FMVSY150/MT-76
FMVSY250/MT-76
FMVSY400/MT-76
FMVMY175/MT-76
FMVMY250/MT-76
FMVMY400/MT-76
FMVMY250/MT-76 S828
FMVMY320/MT-76 S828
FMVMY400/MT-76 S828
FMVCY175/MT-76
FMVCY250/MT-76
FMVCY400/MT-76

or fusing option.

ɀ Luminaire housing and door frame
assembly – die-cast aluminum.
ɀ External hardware – stainless steel.
ɀ Lens – heat and impact-resistant glass.
ɀ Yoke – aluminum.

CH0 0 7 L - 8

Yoke mounted
FMV Champ
floodlight with
SFA6 slipfitter
adapter.

Certifications and Compliances:

Standard Materials:

880

Typedriver Name: TS name csm no.: 100

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0881-2 Name: 7L-881

DATE: JAN 19 2006

Time: 5:58:41 PM Operator: JB

150-400W FMV Series
®

Champ H.I.D. Luminaires

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data
Dimensions

7L

Isofootcandle Chart
FMV 400W high pressure sodium
Catalog number FMVSY400-76
Lamp: 400 watt clear high pressure sodium
Lumen rating: 50,000

Isofootcandle Chart
FMV 400W metal halide
Catalog number FMVMY400-76
Lamp: 400 watt clear metal halide
Lumen rating: 34,000

For 150 watt high pressure sodium, multiply footcandles by 0.32. For
250 watt superior high pressure sodium, multiply footcandles by 0.6.

For 250 watt clear metal halide, multiply footcandles by 0.6.

Luminaire located at 0°, 0°
Aiming angle at 45°

(Note: Luminaire aiming angle limited to
30° past vertical through 60° before
vertical.)

0°=2.9
30°=2.5
45°=2.1
ɀ 50 hertz ballast – luminaires can be ordered with either 220V 50 hertz
or 240V 50 hertz ballasts.
ɀ Ballast-Gard TM starter cut-out switch – prevents starter pulsing when
lamp is cycling or inoperative; prolongs ballast and ignitor life.
Available for use with 70-400W HPS only . . . . . . . . . . . . . . add suffix BG.

Dimensions

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:881))

Luminaire located at 0°, 0°
Aiming angle at 45°

(Note: Luminaire aiming angle limited to
30° past vertical through 60° before
vertical.)

Table of Footcandle Values at Various
Mounting Heights FMV 400W

EPA Data – Aiming Angle

CH0 0 7 L - 9

COLOR: CMYK

CAN: 1-800-265-0502

Footcandle Values for both Isofootcandle Charts
Mounting
Height
A
B
C
15′
8.0
4.0
2.0
20′
4.5
2.3
1.1
25′
2.9
1.4
0.7
30′
2.0
1.0
0.5
35′
1.5
0.7
0.4
40′
1.1
0.6
0.3

Copyright© 2006 Cooper Crouse-Hinds

D
0.8
0.5
0.3
0.2
0.15
0.11

E
0.4
0.23
0.14
0.1
0.07
0.06

881

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0882-2 Name: 7L-882

7L

100:
DATE: JAN 19 2006

Time: 5:58:42 PM Operator: JB

COLOR: CMYK

TCP: 15001

Temperature Performance Data
Net Fixture Weights

150-400W FMV Series
Champ® H.I.D. Luminaires

Temperature Performance Data:
Class 1
Lamp
Watts

Ambient
Temp °C

Non-restricted
Breathing

Restricted
Breathing (S826TB)

Division 2

Zone 2

High Pressure Sodium
150 Watt
40
55
65
250 Watt
40
55
65
400 Watt
40
55
65
Metal Halide & Pulse Start
175 Watt
40
55
65
250 Watt
40
55
65
320/400 Watt
40
55
65
Mercury Vapor
175 Watt
40
55
65
250 Watt
40
55
65
400 Watt
40
55
65

Supply
Wire °C

T2C
T2C
T2B
T2
T2
325 °C
T1
T1
—

T6
T5
T4
T4
T4
T4
T4
T3
—

75
90
90
75
90
90
75
90
—

T2
T2
325 °C
T2
T2
325 °C
325 °C
T1
—

T4
T3
T3
T4
T3
T3
T3
T3
—

75
90
90
75
90
90
75
90
—

325 °C
325 °C
325 °C
325 °C
325 °C
325 °C
325 °C
T1
—

T4
T3
T3
T3
T3
T3
T3
T3
—

75
90
90
75
90
90
75
90
—

US: 1-866-764-5454

CAN: 1-800-265-0502

Net Weights (lbs.)
Luminaires FMVS
FMVM
FMVC
70-150W
37
—
—
175-250W
40
42
37
400W
44
44
41
SFA6 (Slipfitter Adapter) – Add 4 lbs.
SWB6 (Wall Bracket) – Add 6 lbs.

882

STIBOINFO((CRH:66008com:7L:882))
CH0 0 7 L - 9

Typedriver Name: TS name csm no.: 100

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0883-9 Name: 7L-883

100:
DATE: JAN 19 2006

Time: 5:58:42 PM Operator: RB

COLOR: CMYK

ɀ

1000-1500W FMV

ɀ

High Wattage Series
Champ® H.I.D.
Luminaires

TCP: 15001

Typedriver Name: TS name csm no.: 100

Wet Locations
3, 3R

7L

Application:
FMV1000 Series Very High Wattage
Floodlights with wet locations suitability are
used outdoors:
ɀ at refineries, chemical, pharmaceutical and
petrochemical plants, waste and sewage
treatment plants, pulp and paper mills and
other industrial facilities containing
hazardous (classified) areas.
ɀ to light process areas, storage tank and
rack areas, loading docks, rail yards, building
perimeters, parking areas, vehicle and
pedestrian passageways and even sports
applications.
ɀ for security and safety lighting in industrial
and process facilities.
ɀ in industrial locations where the damaging
effects of rain, snow, wind, moisture, dirt,
corrosion, vibration and rough usage may be
a problem.
ɀ to produce superior light at low cost with
great efficiency.

Standard Materials:
ɀ Housing—Copper-free aluminum
ɀ External hardware—stainless steel
ɀ Yoke—Steel
ɀ Lens—Heat and impact-resistant tempered
glass
ɀ Gasketing—neoprene

Standard Finishes:
ɀ Aluminum—epoxy powder coat
ɀ Steel (Yoke)—hot dipped galvanized
ɀ Stainless Steel—natural

Ratings (Electrical/Size):
Sources/Wattages (Mogul Base
Lamps)

ɀ High Pressure Sodium (HPS)
1000W
ɀ Metal Halide (MH)
1000W & 1500W
ɀ Mercury Vapor (MV)
1000W
Voltages
Standard Voltage Ballasts
Hub Size
ɀ 3⁄4⍯ NPT
ɀ Furnished prewired with cord connector
And 3 ft. of 14/3 SO cord

Certifications and
Compliances:

Key Features
ɀ Heavy duty copper-free aluminum
housing with epoxy powder coat
finish.
Unique 3 piece housing design.
ɀ Prewired with 3 ft. of 14/3 SO cord.
ɀ Requires only two bolts to mount
ɀ Easily adjustable to aim light where
desired
ɀ Heat and impact resistant tempered
glass lens
ɀ Heavy duty neoprene gasketing
ɀ Anodized precision formed
aluminum reflector
ɀ NEMA 7x6 beam spread for light
pattern
ɀ Removable top plate provides easy
access to lamp compartment

specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

Allows mounting location flexiblity, roof top, wall
mount, etc.
Provides exceptional stability
Insures a reliable and long life environmental seal
Superior beam control, distribution and efficiency.
The ideal light distribution for industrial applications
Minimizes maintenance. Lens removal is not
required for lamp replacement.

Suffix to be
Added to
Description
Cat. No.
ɀ Fusing. . . . . . . . . . . . . . . . . . . . . . . . . . S658*
ɀ Slipfitter adapter (To be mounted to
yoke mount luminaire) . . . . . . . . . . . . . . . SFA6
(Note: SFA6 fits onto 2⍯ pipe/conduit)
ɀ Wall bracket (use with slipfitter adapter
SFA6 for easy wall mounting &
increased adjustability.) . . . . . . . . . . . . . SWB6

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:883))

Provides coolest operation for increased
component life
Simplifies installation

Options:

ɀ NEC:
Class I, Division 2, Groups A, B, C, D
ɀ UL Standards
844
1598 Luminaires
* When ordering fuses for luminaires, option S658, you must

CH0 0 7 L 1 0

Benefits
Superior performance, life and corrosion resistance

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

883

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0884-3 Name: 7L-884

7L

DATE: JAN 19 2006

Time: 5:58:43 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Ordering Information
Dimensions and Weights

1000-1500 FMV
High Wattage Series
Champ® H.I.D. Luminaires

Dimensions:

Net Luminaire Weights (lbs)

Ordering Information:
*To complete Catalog Number, add Voltage and Options suffix(es)

Luminaire Series
FMVSY1000
FMVMY1000
FMVMY1500
FMVCY1000

Weight (lbs.)
95
88
98
92

Example: FMVSY1000/480-76-S658
Lamp Type
High Pressure
Sodium
Metal Halide
Pulse Start
Metal Halide
Mercury Vapor

Watts
1000

Base Catalog No.*
FMVSY1000 -76

1000
1500
1000

FMVMY1000 -76
FMVMY1500 -76
FMVMY1000 -76 S828

1000

FMVCY1000

-76

Complete the Catalog Number by Adding Voltage and Options Suffixes as Follows:
1.
Standard Voltages - Add one of the following Suffixes (For other Voltages Consult
Cooper Crouse-Hinds)
Voltage
120
480
MT
TT
Suffix
/120
/480
/MT
/TT
2.

884

STIBOINFO((CRH:66008com:7L:884))
CH0 7 L - 1 1

US: 1-866-764-5454

Options - Add the Required Options Suffixes from page 883, In Alpha-numeric Order

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0885-2 Name: 7L-885

100:
DATE: JAN 19 2006

Time: 5:58:44 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data
Temperature Performance Data

1000-1500 FMV
High Wattage Series
Champ® H.I.D. Luminaires

7L

Isofootcandle Chart
FMV1000W High Pressure Sodium
Catalog Number FMVSY1000-76
Lamp: 1000 watt clear high pressure sodium
Lumen rating: 140,000

Isofootcandle Chart
FMV1000W Metal Halide
Catalog Number FMVMY1000-76
Lamp: 1000 watt clear metal halide
Lumen rating: 110,000
For 1500 watt clear metal halide, multiply footcandles by 1.4.

Luminaire located at 0°, 0°
Aiming Angle at 45°
(Note: Luminaire aiming angle limited to 45° past vertical through 60°
before vertical.)

Luminaire located at 0°, 0°
Aiming Angle at 45°
(Note: Luminaire aiming angle limited to 45° past vertical through 60°
before vertical.)

Footcandle Table for FMVS1000W

Effective Projected Area (EPA)

Mounting
Height

ɀ For windloading
ɀ For proper pole selection
Aiming Angle
EPA
0°
3.5 ft2
45°
3.6 ft2
60°
2.9 ft2

20′
25′
30′
35′
40′

Footcandle Values for
Isofootcandle Lines
A
B
C
12.6
6.4
3.1
8.1
3.9
2.0
5.6
2.8
1.4
4.2
2.1
1.0
3.1
1.6
0.8

D
1.4
0.8
0.6
.42
.32

E
.64
0.4
2.8
0.2
.17

Temperature Performance Data:
Class 1

1000

Non-restricted
Breathing
Division 2
T1

Restricted
Breathing
Zone 2
—

1000

T1

—

40 °C

1000

T1

—

40 °C

Lamp

Watts

HPS
Metal
Halide
Mercury
Vapor

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:885))
CH0 0 7 L - 7

CAN: 1-800-265-0502

Ambient
40 °C

Copyright© 2006 Cooper Crouse-Hinds

885

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0886-2 Name: 7L-886

7L

100:
DATE: JAN 19 2006

Time: 5:58:45 PM Operator: JB

COLOR: CMYK

TCP: 15001

F2MV, FMV, FMV1000 Series
Floodlights
Accessories

2.5⍯ O.D.
SWB6 Wall Bracket
SFA6 Slipfitter

886

STIBOINFO((CRH:66008com:7L:886))
CH0 0 7 L 1 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0887-15 Name: 7L-887

DATE: JAN 19 2006

Time: 5:58:46 PM Operator: RB

FZD Series Floodlight Luminaire

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 & 2, Groups C & D
Cl, I, Zone I
Marine Locations
Wet Locations, IP66

7L

Finally, a true floodlight luminaire for
hazardous areas.
Cooper Crouse-Hinds® FZD-Series TM Luminaires are the first to deliver
NEMA 7x6 floodlight distribution patterns for Class I, Division 1 and
Zone 1 environments. That means you’ll need fewer of them to
illuminate a given area. With their labor-saving features and flexible
mounting options, the FZD series is ideal for:
ɀ heavy process industries where flammable or explosive vapors or
gases are present
ɀ hazardous areas, both indoors and outdoors, including those
requiring elevated ambient capability, where long life and low
maintenance costs are desired
ɀ petroleum refineries, chemical, petrochemical and other heavyprocess industrial facilities
ɀ mounting to a wall, structure or pole (with pole mount adapter
accessory)

FZD with separate
ballest enclosure

KEY FEATURES AND BENEFITS
ɀ NEMA 7x6 floodlight distribution pattern is
standard—ideal light distribution for industrial
applications; requires fewer luminaires in general lighting applications than required when
using general-area luminaires with high-bay
reflectors
ɀ Internal reflector—available in wide and
narrow-beam options; enclosed in glass tube,
reducing maintenance and enhancing light
output
ɀ Heavy-duty, cast copper-free aluminum
construction with epoxy powder-coat finish
and stainless steel hardware— provides
long life in industrial, abusive environments

CERTIFICATIONS AND
COMPLIANCES

ɀ Explosionproof threaded construction—
suitable for hazardous and industrial
applications; easy to maintain with no bolted
covers
ɀ O-ring gaskets on all threaded
openings— allow NEMA Type 4X and Marine
Listing for the harshest outdoor environments
ɀ 40°C, 55°C and 65°C ambient
suitability— ideal for use in high ambient
temperature areas common in industrial
facilities
ɀ Factory-sealed ballast housing—keeps
ballast isolated from wiring chamber
ɀ Trunnion (yoke) mount design—standard
construction provides the greatest mounting
flexibility; can be vertically (wall) or
horizontally (rooftop or floor) mounted

NEC/CEC

STANDARD MATERIALS

ɀ Class I, Division 1, Groups B
(with suffix -GB*), C and D
ɀ Class I, Zone 1, Groups IIB+H2
(with suffix -GB*), IIB
ɀ AEx d IIB+H2 (with suffix -GB*), IIB
ɀ Ex d IIB+H2 (with suffix -GB*), IIB
ɀ Marine Locations
ɀ Wet Locations
ɀ Enclosure Type 4X
ɀ IP66
ɀ UL Listed (UL Standards 844, 1598, 1598A,
2279)
ɀ cUL Listed (certified by UL to CSA Standard
C22.2 No. 137 and CAN/CSA-E60079-1)

ɀ luminaire housing, covers, socket holder,
lamptube end rings— copper-free aluminum
ɀ external hardware—stainless steel
ɀ glass lamp tube—heat and impact-resistant
tempered glass
ɀ O-ring gaskets—neoprene/silicone
ɀ yoke—aluminum
ɀ trunnion adapter—brass

*See options for Group B and IIB+H2 ordering information

DIMENSIONS

(inches)

STANDARD FINISHES
ɀ aluminum—Corro-free TM epoxy
powder coat
ɀ stainless steel—natural
ɀ brass—natural

LUMINAIRE WEIGHTS (lbs)
LUMINAIRE
150-watt
175 to 250-watt
400-watt

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:887))
CH0 0 4 F - 5

FZDS (HPS)
72
77
80

CAN: 1-800-265-0502

FZDM (MH)
75
77
80

ɀ Simple installation—requires only two
bolts to mount
ɀ Mounting flexibility—pole mount with
SFA6-XP pole mount adapter (shown below)
or wall or ceiling mount with FZD-KIT1
mounting accessory kit (shown above).

POLE MOUNT ADAPTER

RATINGS
SOURCES/WATTAGES (MOGUL BASE LAMPS)
ɀ HPS—150, 250 & 400 watts
ɀ MH—175, 250 & 400 watts
VOLTAGES
Standard Voltage Ballasts
ɀ Multi-tap (120, 208, 240 & 277 V, 60 Hz)
ɀ 120 V, 60 Hz
ɀ 480 V, 60 Hz
ɀ Tri-tap (120, 277 & 347 V, 60 Hz)
Optional Voltage Ballasts
ɀ 220 V, 60 Hz
ɀ 220 V, 50 Hz
HUB SIZE
ɀ Standard: Two 3⁄4⍯ NPT entries
ɀ Optional: Two 25 mm (M25) entries
(consult Cooper Crouse-Hinds)

EFFECTIVE PROJECTED
AREA (EPA)
ɀ For windloading
ɀ For proper pole selection
AIMING ANGLE
0 degrees
45 degrees

Copyright© 2006 Cooper Crouse-Hinds

EPA
1.8 ft2
2.3 ft2

887

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0888-19 Name: 7L-888

7L

100:
DATE: JAN 19 2006

Time: 5:58:48 PM Operator: RB

FZD Series Floodlight Luminaire

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 & 2, Groups C & D
Cl, I, Zone I
Marine Locations
Wet Locations, IP66

ORDERING INFORMATION

VOLTAGE SUFFIXES

To complete the catalog number, add option suffix(es) if desired.
Example: FZDS2NY400W/MT-S658
CATALOG NUMBER*
YOKE MOUNT WITH
3⁄4⍯ NPT HUBS
LAMP TYPE
WATTS
WIDE-BEAM REFLECTOR—NEMA 7x6 DISTRIBUTION
High-Pressure Sodium
150**
FZDS2NY150W/MT
250
FZDS2NY250W/MT
400
FZDS2NY400W/MT
Metal Halide
175
FZDM2NY175W/MT
250
FZDM2NY250W/MT
400
FZDM2NY400W/MT
Pulse-Start Metal Halide
175
FZDM2NY175W/MT-S828
250
FZDM2NY250W/MT-S828
400
FZDM2NY400W/MT-S828
NARROW-BEAM REFLECTOR—SPOTLIGHT DISTRIBUTION
High-Pressure Sodium
150**
FZDS2NY150N/MT
250
FZDS2NY250N/MT
400
FZDS2NY400N/MT
Metal Halide
175
FZDM2NY175N/MT
250
FZDM2NY250N/MT
400
FZDM2NY400N/MT
Pulse-Start Metal Halide
175
FZDM2NY175N/MT-S828
250
FZDM2NY250N/MT-S828
400
FZDM2NY400N/MT-S828

STANDARD VOLTAGES SUFFIX OPTIONAL VOLTAGES SUFFIX
Multi-tap (120, 208, 240,
277 V, 60 Hz)
/MT
220 V, 50 Hz
/220 50
Tri-tap (120, 277, 347 V,
60 Hz)
/TT
220 V, 60 Hz
/220
120 V, 60 Hz
/120
480 V, 60 Hz
/480

*All FZD catalog numbers shown above are with multi-tap ballasts (120, 208, 240 & 277 V, 60 Hz).
The ‘‘MT’’ in the catalog number may be changed to any of the voltage suffixes listed below.
**150-watt HPS luminaires are furnished with ANSI spec/S55 ballasts for 55 V lamps.

FZD WITH SEPARATE BALLAST
ENCLOSURE
GLASS FIBER REINFORCED POLYESTER
BALLAST ENCLOSURE WITH CABLE ENTRY
LAMP
WATTS T-CODE CATALOG
TYPE
NUMBER
WIDE BEAM RELFECTOR – NEMA 7×6 DISTRIBUTION
HPS/MH
250
T4
NOR 000 005 192 506
Metal Halide
400
T3
NOR 000 005 194 106
High Pressure Sodium 400
T3
NOR 000 005 194 006
NARROW BEAM RELFECTOR – SPOTLIGHT DISTRIBUTION
HPS/MH
250
T4
NOR 000 005 192 505
Metal Halide
400
T3
NOR 000 005 194 105
High Pressure Sodium 400
T3
NOR 000 005 194 005

SUFFIX TO ADD
TO CAT.NO.
Ballast-Gard TM starter cut-out switch prevents starter
-BG
pulsing when lamp is cycling or inoperative.
Prolongs ballast and igniter life. HPS only. Not
available with IR option.
Factory Assembled with HID lamp installed for
-FA
additional labor savings.
Factory Certified: Class I, Division 1, Group B and
-GB
Class I, Zone 1, Group IIB+H2
Instant Restrike enables a hot HPS lamp to
-IR
immediately restrike after a momentary loss of arc
due to voltage fluctuation or power outage. It has no
effect on the warm-up period of cold lamps.
Available for use with 150-watt HPS only.
Fusing protects ballast and capacitor against
-S658*
abnormal line conditions.

OPTIONS

ACCESSORIES

(order separately)
FOR POLE MOUNTING
Pole mount adapter
ɀ Class I, Division 1, Groups B, C and D
ɀ Attach to yoke; fits 2⍯ NPT conduit pole
Flexible explosionproof coupling
Elbow fitting

WIDE BEAM RELFECTOR – NEMA 7×6 DISTRIBUTION
HPS/MH
250
T4
NOR 000 005 192 502
Metal Halide
400
T3
NOR 000 005 194 102
High Pressure Sodium 400
T3
NOR 000 005 194 002
NARROW BEAM RELFECTOR – SPOTLIGHT DISTRIBUTION
HPS/MH
250
T4
NOR 000 005 192 501
Metal Halide
400
T3
NOR 000 005 194 101
High Pressure Sodium 400
T3
NOR 000 005 194 001

STIBOINFO((CRH:66008com:7L:888))

CAN: 1-800-265-0502

ECLK236
EL296-SA

TEMPERATURE PERFORMANCE DATA

250-watt HPS

400-watt HPS

175-watt
Metal Halide

400-watt
Metal Halide

US: 1-866-764-5454

SFA6-XP

S658 cannot be ordered with /MT in the catalog number.

250-watt
Metal Halide

888

CATALOG NO.

FOR WALL OR CEILING MOUNTING
Kit includes:
EABC26-SA conduit outlet box,
ECLK236 flexible explosionproof coupling,
and EL296-SA elbow fitting.
FZD-KIT1
* When ordering fuses for luminaires, option S658, you must specify the operating voltage.

LAMP
150-watt HPS

STAINLESS STEEL BALLAST ENCLOSURE
WITH CABLE ENTRY

CH0 0 4 F - 5

COLOR: CMYK

AMBIENT
TEMP °C
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65

Copyright© 2006 Cooper Crouse-Hinds

CLASS I,
DIVISION 1, ZONE 1
T3C
T3C
T3B
T3C
T3C
T3B
T3C
T3C
T3B
T3A
T3
T3
T3A
T3
T3
T3A
T3
T3

SUPPLY
WIRE °C
75
75
90
75
75
90
75
75
90
75
75
90
75
75
90
75
75
90

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0889-4 Name: 7L-889

DATE: JAN 19 2006

Time: 5:58:49 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data

FZD Series Floodlight Luminaire

7L

PHOTOMETRICS
Note: There are no aiming angle limitations for the FZD. The only limitations are those encountered by interference of the
trunnion arm. The trunnion arm may be mounted on vertical or horizontal surfaces to overcome any limitations.

HPS Narrow Beam Reflector

HPS Wide Beam Reflector

ISO FOOTCANDLE CHART
FZD 400 W High Pressure
Sodium (HPS)
Catalog Number
FZDS2NY400N
Lamp: 400 W Clear HPS
Lumen rating: 50,000
Luminaire located at
0°,0°Aiming Angle
at 45°down from horizontal
For 150 W HPS,
multiply footcandles by 0.32.
For 250 W HPS,
multiply footcandles by 0.6.
MOUNTING
HEIGHT
10′
12′
16′
20′
25′

A
200.00
138.89
78.13
50.00
32.00

FOOTCANDLE VALUES FOR
ISO FOOTCANDLE LINES
B
C
D
E
F
100.00 50.00 20.00 10.00 5.00
69.44 34.72 13.89 6.94 3.47
39.06 19.53 7.81 3.91 1.95
25.00 12.50 5.00 2.50 1.25
16.00 8.00 3.20 1.60 0.8

ISO FOOTCANDLE CHART
FZD 400 W High Pressure
Sodium (HPS)
Catalog Number
FZDS2NY400W
Lamp: 400 W Clear HPS
Lumen rating: 50,000
Luminaire located at
0°,0°Aiming Angle
at 45°down from horizontal
For 150 W HPS,
multiply footcandles by 0.32.
For 250 W HPS,
multiply footcandles by 0.6.
MOUNTING
HEIGHT

G
2.00
1.39
0.78
0.50
0.32

MH Narrow Beam Reflector

A
20.00
13.89
7.81
5.00
3.20

10′
12′
16′
20′
25′

FOOTCANDLE VALUES FOR
ISO FOOTCANDLE LINES
B
C
D
E
10.00
5.00
2.00
1.00
6.94
3.47
1.39
0.69
3.91
1.95
0.78
0.39
2.50
1.25
0.50
0.25
1.60
0.80
0.32
0.16

MH Wide Beam Reflector

ISO FOOTCANDLE CHART
FZD 400 W Metal Halide (MH)
Catalog Number
FZDM2NY400N
Lamp: 400 W Clear MH
Lumen rating: 34,000
Luminaire located at
0°,0°Aiming Angle
at 45°down from horizontal
For 175 W MH,
multiply footcandles by 0.38.
For 250 W MH,
multiply footcandles by 0.6.
MOUNTING
HEIGHT
10′
12′
16′
20′
25′

FOOTCANDLE VALUES FOR
ISO FOOTCANDLE LINES
A
B
C
D
E
F
100.00 50.00 20.00 10.00 5.00 2.00
64.99 34.72 13.89 6.94 3.47 1.39
39.06 19.53 7.81 3.91 1.95 0.78
25.00 12.50 5.00 2.50 1.25 0.50
16.00 8.00 3.20 1.60 0.80 0.32

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:889))
CH0 0 4 F - 5

F
0.50
0.35
0.20
0.13
0.08

G
1.00
0.69
0.39
0.25
0.16

ISO FOOTCANDLE CHART
FZD 400 W Metal Halide
(MH)
Catalog Number
FZDM2NY400W
Lamp: 400 W Clear MH
Lumen rating: 34,000
Luminaire located at
0°,0°Aiming Angle
at 45°down from horizontal
For 175 W MH,
multiply footcandles by 0.38.
For 250 W MH,
multiply footcandles by 0.6.
MOUNTING
HEIGHT
A
10′
12′
16′
20′
25′

CAN: 1-800-265-0502

B
20.00
13.89
7.81
5.00
3.20

FOOTCANDLE VALUES FOR
ISO FOOTCANDLE LINES
C
D
E
F
10.00
5.00
2.00
1.00
6.49
3.47
1.39
0.69
3.91
1.95
0.78
0.39
2.50
1.25
0.50
0.25
1.60
0.80
0.32
0.16

Copyright© 2006 Cooper Crouse-Hinds

0.50
0.35
0.20
0.13
0.08

889

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0890-4 Name: 7L-890

7L

100:
DATE: JAN 19 2006

Time: 5:58:50 PM Operator: JB

Hazard ȿ Gard®
H.I.D. Floodlights

Hazard ȿ Gard luminaires with Trunnion Arm (S812
suffix) and EV912 high bay reflector are used in:
ɀ heavy process industries where flammable or
explosive vapors or gases are present
ɀ hazardous areas, both indoors and outdoors
where long life and low maintenance costs are
desired
ɀ petroleum refineries, chemical, petrochemical and
other heavy process industry facilities
ɀ hazardous locations requiring elevated ambient
capability
ɀ for mounting to a wall or structure
ɀ mounted on a pole, when used with the SFA6
slipfitter adapter

ɀ Luminaire is factory wired; power is fed through
‘‘wireless’’ connection block which serves as a
mechanical seal between conduit and ballast
compartments, eliminating the need for an external,
field installed seal. The result is fast, easy
installation.
ɀ High bay reflectors of Alzak® aluminum
ɀ Internally fluted glass globes reduce glare and
provide comfortable viewing light.
ɀ Wide range of light sources and wattages to meet
specific lighting needs – 50, 70, 100, 150, 200, 250
and 400W high pressure sodium (HPS); 100, 175,
250 and 400W mercury vapor (MV); 70, 100, 175,
250 and 400W metal halide (MH).
ɀ High power factor (90%+) ballasts reduce power
costs – allow more luminaires per circuit.
ɀ Elevated ambient capability permits reliable
operation at high ambient temperature. Selected
luminaires are suitable for ambient temperatures up
to 65°C.
ɀ Integral ballasts – separate ballasts are not
required. Lowest installed cost.
ɀ Factory sealed, porcelain, mogul base socket.
ɀ the trunion arm gives you the ability to offer a
Hazard ȿ Gard floodlight with varying degrees of
adjustability between –90° and +90°.
ɀ when mounting on a wall, there are numerous
mounting arrangements – due to the pre-drilled
openings in the wall bracket.

Size Ranges:
3⁄4⍯

Electrical Rating Ranges:
ɀ 120, 208, 240, 277, 347, 480, 600, multi-tap#.
ɀ 50 to 400 watts

Certifications and
Compliances:
ɀ NEC/CEC
Class I, Division 1 and 2, Groups B (with GB
suffix), C, D
ɀ UL Standard: 844, 595
ɀ CSA Standard: C22.2 No. 137
ɀ Catalog number includes Guard, Trunnion Arm
and High Bay Reflector

Luminaire Cat. No.
NOTE: Replace ‘‘volts’’ with Suffix from Voltage
Suffix Table below

HIGH PRESSURE SODIUM
EVMA42051/volts S812 EV3912
EVMA42071/volts S812 EV3912
EVMA42101/volts S812 EV3912
EVMA42151/volts S812 EV3912
EVMA42201/volts S812 EV3912
EVMA42251/volts S812 EV3912
EVMA42401/volts S812 EV3912
MERCURY VAPOR
EVMA82101/volts S812 EV3912
EVMA82171/volts S812 EV3912
EVMA82251/volts S812 EV3912
EVMA82401/volts S812 EV3912
METAL HALIDE
EVMA92071/volts S812 EV3912
EVMA92101/volts S812 EV3912
EVMA92171/volts S812 EV3912
EVMA92251/volts S812 EV3912
EVMA92401/volts S812 EV3912

Standard Materials:
ɀ Mounting module, cover, ballast housing, guard,
globe ring – copper-free aluminum
ɀ Globe – heat and impact resistant glass
ɀ Exterior hardware – stainless steel
ɀ Lamp socket – porcelain with stainless steel screw
shell
ɀ Reflector – high bay: Alzak aluminum

Standard Finishes:
ɀ Copper-free aluminum – epoxy powder coat
ɀ Alzak – natural (anodized)

Options:
Suffix to be
Added to
Description
Cat. No.
ɀ Fused . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S658
ɀ BallastɀGard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG
ɀ 50-400 HPS only
ɀ Instant Restrike. . . . . . . . . . . . . . . . . . . . . . . . . . . . . IR
ɀ Cannot be used with BG or QTZ options
ɀ 50-150W LX HPS only
ɀ Quartz Auxiliary Lighting. . . . . . . . . . . . . . . . . . . QTZ
ɀ Not available with 400W MH or MV
ɀ Uses 100 watt single ended lamp
ɀ Lamp not included
ɀ Group B Suitability . . . . . . . . . . . . . . . . . . . . . . . . . GB

Hub
Size
3⁄4

STIBOINFO((CRH:66008com:7L:890))

Watts Hub
Size
50
70
100
150

3⁄4
3⁄4
3⁄4
3⁄4
3⁄4
3⁄4
3⁄4

100
175
250
400

3⁄4

70
100
175
250
400

3⁄4

3⁄4
3⁄4
3⁄4

3⁄4
3⁄4
3⁄4
3⁄4

Temperature Performance
Data
Hazard ȿ Gard Luminaire with
Trunnion Arm (S812 suffix)
Maximum Ambient
Class I
Watts
40°C
55°C
High Pressure Sodium
50
T4
T4
70
T4
T4
100
T4
T4
150
T4
T4
200
T3A
—
250
T3A
—
400
T3A
—
Mercury Vapor
100
T3
T3
175
T3
T3
250
T3
T3
400
T2D
—
Metal Halide
70
T3
T3
100
T3
T3
175
T3
T3
250
T3
T3
400
T2D
—

T3C
T3C
T3C
T3C
—
—
—
—
—
—
—
—
—
—
—
—

Alzak is a registered trademark of ALCOA
# CSA Certified luminaires are not available with multi-tap
ballast or S658 fuse option.

Cat. #
EABC26

ECGJH
Flexible
Length
30

UNL
90° Angle

US: 1-866-764-5454

65°C

NOTE: See Section 4L for additional
luminaire information.

EABC

Size
3⁄4 to 3⁄4

CH0 0 7 L 1 5

Typedriver Name: TS name csm no.: 100

Ordering Information

Features:

890

TCP: 15001

Cl. I, Div. 1 & 2, Groups C & D
Cl. I, Div. 1 & 2, Groups B, C, D (Add suffix GB)
Cl. I, Zone 1
Marine Locations, IP66
Wet Locations

Factory Sealed

Application:

COLOR: CMYK

Cat. #
UNL205

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Size
3⁄4

Cat. #
ECGJH230

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0891-2 Name: 7L-891

100:
DATE: JAN 19 2006

Time: 5:58:51 PM Operator: JB

Incandescent Floodlights

Application:

Standard Materials:

RCDE incandescent lighting
luminaires are permanently
installed to provide general
illumination in locations having
hazardous atmospheres, such
as:
ɀ oil refineries
ɀ oil and gasoline loading docks
ɀ aircraft servicing docks and
shelters
ɀ distilleries
ɀ paint manufacturing plants
ɀ pumping stations
ɀ other Class I, Groups C and D
locations

Body – copper-free aluminum;
Lens – glass, heat and impact
resistant

RCDE incandescent lighting
luminaires have fixed mountings
as follows:
ɀ RCDE-6 – junction box base
with four mounting feet or 2⍯
threaded hub (fill sealing
chamber with Chico® A after
conductors are in place)
ɀ RCDE-6 adjustment allows
rotation of 360° horizontally and
75° vertically.
ɀ Locking screws hold housing
firmly in position
ɀ RCDE-10 – junction box base
with four mounting feet
ɀ door which threads into
housing includes heat and
impact-resistant lens. Door has
notches or holes provided for
ease of removing or tightening
ɀ factory wired leads through
explosion-proof seal to junction
box
ɀ adjustment that allows rotation
of 360° horizontally and 135°
vertically. Locking bolts or
clamps hold housing firmly in
position

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 and 2, Groups C,D
Cl. I, Zone 1

RCDE Series

Features:

COLOR: CMYK

7L

Standard Finishes:
ɀ Natural

Size Ranges:
ɀ RCDE – Fixed mounting –
3⁄4⍯ hubs

Capacity Ranges:
ɀ RCDE-6 – 150 watt, PAR38 or
R40; 300 watt, R40 (medium
base)
ɀ RCDE-10 – 500 watt, PAR64
(Ext. Mog End Prong)

Certifications and
Compliances:
ɀ NEC/CEC:
RCDE – Class I, Division 1 and
2, Groups C,D Class I, Zone 1
(see photometric data listing)
ɀ UL Standard: 844
ɀ CSA Standard: C22.2 No. 137
(RCDE6 only)
Note: CEC/CSA Certified RCDE6- Cooper
Crouse-Hinds Canada luminaires only.

RCDE-10

RCDE-6
Description
Junction box base
(2⍯ threaded hub)
Junction box base
(4 mtg. feet)

Cat. #
44978A

Description
Junction box base
(4 mtg. feet)

Cat. #
47282A

44719B

Ordering
Information:
After identifying the hazardous
area, select the model of lighting
luminaire required for that area.
Then from the photometric data,
select appropriate Cat. No.
based on type of mounting
desired. Example: RCDE-10
No. 47282

Temperature Performance Data
(based on 40°C Ambient)
150W
RCDE-6
T3B
RCDE-10

300W
T2B

500W
T3C

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7L:891))
CH0 0 7 L 1 6

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

891

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0892-2 Name: 7L-892

7L

DATE: JAN 19 2006

Time: 5:59:55 PM Operator: JB

COLOR: CMYK

TCP: 15001

Dimensions & Weights
Photometric Data
Cl. I, Div. 1 and 2, Group D
Explosionproof

RCDE Series
Incandescent Floodlights

Dimensions (inches)

Dimensions
RCDE-10

RCDE-6

Fixture Weights
RCDE-6
Cat. #
44719B
44978A

RCDE-10
Lbs.
(Net)
21.0
21.0

Lbs.
(Net)
26.0

Cat. #
47282A

RCDE
Photometric Data
Lamp Watts
and Type

Location

150 Watt
PAR38 Flood
150 Watt
PAR38 Spot

Class I
Groups C,D

300 Watt*
R40 Flood
300 Watt
R40 Spot

Class I
Group D

500 Watt, PAR64
(500 PAR64/NSP)
500 Watt, PAR64
(500 PAR64/MFL)

Class I,
Group D

500 Watt, PAR64
(500 PAR64/WFL)

Beam Spread
Hor.
Vert.

Beam
Lumens

Av. Max.
Candle Power

60°

60°

1690

4000

28°

28°

1200

11500

123°

123°

3200

1950

60°

60°

3100

8900

19°

14°

3000

110000

35°

19°

3300

37000

55°

32°

3400

13000

Model

RCDE-6

RCDE-10

* CSA certified fixtures are for 150 watt lamp maximum.

892

STIBOINFO((CRH:66008com:7L:892))
CH0 0 7 L 1 7

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0893-3 Name: 8L-893

100:
DATE: JAN 19 2006

Time: 5:59:56 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Lighting Accessories
Hazardous and Non-Hazardous

8L

Description

Page No.

Application/Selection

894-897

Hazardous Area Hangers
Adjustable Type
UNR

911

Flexible Type
EC Series

905

Locking Coupling
COUP Series

911

Outlet Box Type
EAHC/EFHC Series
GUA/GUF Series
CPS Series

906
909, 910
908

Outlet Box Type with Flexible Cushion
EFHX Series

907

Non-Hazardous Area Fittings
Conduit Clamps
CHS Series

903

Non-Hazardous Area Hangers – Flexible Type
Ball and Cushion
ARB Series
UNJ/UNJC Series

901
899, 900

Cushion – Vaportight
AHG Series
UNHC Series

899, 900
903

Hooks and Loops
UNE, UNH, UNHC Series

902, 903

Outlet Box – Ball and Cushion
AL Series

898, 900

Quick Disconnect Type
FHM Series

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8L:893))
CH0 0 0 0 7 L

CAN: 1-800-265-0502

904

Copyright© 2006 Cooper Crouse-Hinds

893

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0894-3 Name: 8L-894

8L

100:
DATE: JAN 19 2006

Time: 5:59:57 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Luminaire Hangers
and Accessories – For Pendant Mount
Application & Selection

Application:

Typical Luminaire Weights:

Luminaire hangers listed in this section are
used for pendant suspension of incandescent,
high intensity discharge and fluorescent
industrial luminaires. They are especially
suitable for use in locations where moisture,
dust, and corrosion are a problem.

Hangers for Non-Hazardous
Locations:
ɀ Hangers listed provide a wide variety of
mounting means. Luminaires may be
suspended from cast outlet boxes, stamped
steel outlet boxes, or directly from the conduit
system. Also offered are several styles of hook
type hangers, used to suspend luminaires by
means of conduit stems or support rods from
span wires, horizontal conduit and luminaire
loops.
ɀ All hangers are flexible, permitting luminaire
and supporting stem to swing freely. This
feature permits luminaires to hang plumb and
prevents damage to the luminaire, stem and
outlet box in case of high wind or accidental
impact.
ɀ Hangers are constructed so that luminaires
cannot be rotated, thereby eliminating wire
twisting and possible damage to connections.
ɀ Cushion hangers, listed for most styles,
include a spring which carries the weight of
the luminaire. This feature prolongs lamp life
and protects the luminaire assembly from
shock or vibration.
ɀ All hangers are easily installed. With many,
the luminaire, stem and support member can
be assembled and wired at the work bench
before making the final installation. With
several, a quick disconnect plug and
receptacle feature is either provided or can be
easily arranged, to facilitate luminaire
installation and removal for maintenance.

Luminaire Type

Weight
(lbs.)
Luminaire Type

Incandescent:

H.I.D.:

VAPORGARD TM Series
VDA12
11⁄2
VDA12G
4
VDA12GP
41⁄4
VDA15
11⁄4
VDA15G
3
VDA15GP
31⁄4
VDA23
11⁄2
VDA23G
4
V Series
V275
23⁄4
V2759
41⁄4
EV Series
EVA240
71⁄2
EVA210
73⁄4
EVA215
8
EVA220
101⁄2
EVA230
19
EVA292
18
CorroȿGard® Series
NDA32
51⁄2
NDA32G
71⁄2
NDA33
51⁄2
NDA33G
81⁄4

Champ® Series
AMV
DMVC2A100GP
DMVC2A175GP
DMVC2A250GP
DMVM2A175GP
DMVM2A250GP
DMVS2A070GP
DMVS2A100GP
DMVS2A150GP
LMVS2A035GP
LMVS2A050GP
LMVS2A070GP
LMVS2A100GP
VMVC2A100GP
VMVC2A175GP
VMVC2A250GP
VMVC2A250GR305
VMVC2A250GRD4
VMVC2A400GR305
VMVC2A400GRD4
VMVM2A175GP
VMVM2A250GP
VMVM2A250GR305
VMVM2A250GRD4
VMVM2A400GR305
VMVM2A400GRD4
VMVS2A050GP
VMVS2A070GP
VMVS2A100GP
VMVS2A150GP
VMVS2A200GP
VMVS2A200GR305
VMVS2A200GRD4
VMVS2A250GP
VMVS2A250GR305
VMVS2A250GRD4
VMVS2A400GP
VMVS2A400GR305
VMVS2A400GRD4

Hangers for Hazardous
Locations:

Weight
(lbs.)
Luminaire Type

201⁄4
283⁄4
30
313⁄4
33
333⁄4
303⁄4
313⁄4
34
103⁄4
113⁄4
113⁄4
121⁄4
15
171⁄4
31
34
311⁄2
37
341⁄2
171⁄4
34
37
341⁄2
38
351⁄2
151⁄4
161⁄4
161⁄4
161⁄2
31
34
311⁄2
31
34
311⁄2
40
43
401⁄2

ɀ As required by NEC Article 501 and CEC Part
I Section 18, rigid conduit luminaire stems
longer than 12⍯ must be permanently and
effectively braced or flexibility provided in the
form of a fitting or flexible support.
ɀ A variety of hangers is offered for both rigid
conduit suspension and flexible suspension.
Flexible luminaire hangers listed comply with
NEC Article 501 and CEC Part I Section 18 and
also permit luminaires to hang plumb.

Considerations for Selection:
Location:
ɀ Will it be a hazardous or non-hazardous
location?
ɀ Will it require more stringent corrosion
protection material?
Lighting luminaire to be used:
ɀ Some hangers can be used with a multitude
of luminaires; others are specialized.
ɀ Weight of luminaire is a consideration in
selecting cushion hangers.

894

STIBOINFO((CRH:66008com:8L:894))
CH0 0 7 L - 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Hazard-Gard® Series
EVMA50W HPS
EVMA70W HPS
EVMA100W HPS
EVMA100W MV
EVMA150W HPS
(55V)
EVMA150W HPS
(100V)
EVMA175W MV
EVMA175W MH
EVMA200W HPS
EVMA250W HPS
EVMA250W MV
EVMA250W MH
EVMA400W HPS
EVMA400W MV
EVMA400W MH

Weight
(lbs.)

41
41
45
39
46
45
42
43
47
47
44
44
56
50
52

Fluorescent:
DMVF2A026GP
DMVF2A039GP
DMVFB2A026GP
DMVFB2A039GP
EVF22062
EVF24062
EVF22082
FVN4240
FVN4340
FVN4260
NFW4240
VFA222G
EVFT (2 Lamp)
EVFT (4 Lamp)
FVS

191⁄4
221⁄4
191⁄2
221⁄2
57
94
52
52
54
58
21
4
191⁄2
361⁄2
12

Reflector/Refractor
Type
EV3912
RA64, 636
RA70, 71, 739, 725
RD64, 636
RD70, 71, 739, 725
PR2, 3, 5
R2
R5
GRD4
G241
G245
GR305, GR205

1
11⁄4
1
11⁄4
1
3
131⁄2
13
133⁄4
21⁄4
21⁄4
14

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0895-2 Name: 8L-895

100:
DATE: JAN 19 2006

Time: 5:59:57 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Luminaire Hangers
and Accessories – For Pendant Mount

8L

Quick Selector Chart

Quick Selector Chart

Hanger
Type

Function

NEC/CEC Hazardous
Area
Compliances

Use with
Mtg. Box

Luminaire
Weight
Capacity
(Ball or
Plain Type)

3-48 lbs.

125 lbs.

Body – Feraloy® iron alloy
Nipple – malleable iron
Cover – sheet steel

125 lbs.

Body – copper-free
aluminum
Cover – steel
Loop and assembly –
copper-free aluminum or
steel

Standard
Material

AL

Outlet box and Class I, Div. 2
hanger

Any nonNone
hazardous or needed
Class I, Div. 2

FHM

Quick
disconnect
between
luminaire and
outlet box

Not applicable

Any nonhazardous

AHG

Gasketed
hanger
(vaportight)

Class I, Div. 2;
Class II, Div. 2;
Class III
Wet locations
NEMA 3, 3R

Any nonAny
hazardous or
Div. 2
luminaires

4-30 lbs.

—

Housing – malleable iron
and Feraloy iron alloy
Stem support – Feraloy
iron alloy

UNJ/UNJC

Ball and
cushion
hanger

Class I, Div. 2

Any nonAny
hazardous or
Class I, Div. 2

6-48 lbs.

125 lbs.

Body – malleable iron
Clamp – copper-free
aluminum

ARB

Ball or cushion Class I, Div. 2
hanger

Any nonGRF
hazardous or
Class I, Div. 2

4-30 lbs.

125 lbs.

Body – Feraloy iron alloy

UNE, UNH,
UNHC

Quick
disconnect
hanger hook

Class I, Div. 2

Any nonNot
hazardous or applicable
Class I, Div. 2

12-64 lbs.

125 lbs.

Malleable iron, copperfree aluminum

EC

Explosionproof flexible
hanger

Cl. I, Groups A, B, C, D; Any
Cl. II, Groups E, F, G;
hazardous
Cl. III

Any

—

—

Body – bronze hose
Fittings – steel

GUA, GUJ,
GUF

Explosionproof boxes
and hanger
covers

Cl. I, Groups C, D;
Cl. II, Groups E, F, G;
Cl. III

Any
hazardous

None
needed

—

125 lbs.

Boxes – Feraloy iron alloy
Cover – copper-free
aluminum

EAHC,
EFHC

Explosionproof hanger

Cl. I, Groups A, B, C, D; Any
Cl. II, Groups E, F, G;
hazardous
Cl. III

None
needed

—

125 lbs.

Body – Feraloy iron alloy
Cover – copper-free
aluminum

UNR

Explosionproof
adjustable
hanger

Cl. I, Groups C, D;
Cl. II, Groups E, F, G;
Cl. III

Any
Any
hazardous or
nonhazardous

—

125 lbs.

Feraloy iron alloy

EFH

Explosionproof boxes
and hangers

Cl. I, Groups C, D;
Cl. II, Groups E, F, G;
Cl. III

Any
hazardous

65 lbs.

—

Feraloy iron alloy

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8L:895))
CH0 0 7 L - 1

Use with
Luminaire
Type

Luminaire
Weight
Capacity
(Cushion)

None
needed

None
needed

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

895

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0896-2 Name: 8L-896

8L

100:
DATE: JAN 19 2006

Time: 6:00:01 PM Operator: JB

COLOR: CMYK

TCP: 15001

Luminaire Hangers
and Accessories – For Pendant Mount
Typical Installations

896

STIBOINFO((CRH:66008com:8L:896))
CH0 0 7 L - 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0897-2 Name: 8L-897

DATE: JAN 19 2006

Time: 6:00:03 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Luminaire Hangers
and Accessories – For Pendant Mount

8L

Typical Installations

GUFX

ECHF

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8L:897))
CH0 0 7 L - 3

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

897

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0898-3 Name: 8L-898

8L

100:
DATE: JAN 19 2006

Time: 6:00:04 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Class I, Div. 2, Groups A, B, C, D

AL Flexible Luminaire Hangers
For Pendant Mount

Features:
Functions as both conduit outlet box and
luminaire hanger. Hubs are provided for
threading the conduit directly into the hanger
body. For use with incandescent, H.I.D. and
fluorescent luminaires.
ɀ Supporting nipple, ball or cushion type, is a
universal joint permitting luminaire to swing
through an angle of 20 degrees in any
direction from the perpendicular.
ɀ Cover has one screw hole and one open
slot – easily swung aside for wiring without
removal and possible loss of cover.
ɀ Luminaire, conduit stem and nipple can be
assembled and wired at the work bench. The
assembly is then placed in the hanger body
and luminaire wires spliced to the circuit
wires.
ɀ Provided with a separate grounding wire for
ground connections.

Ball

Ball

Cushion

Cushion

Standard Materials:
ɀ Body – Feraloy® iron alloy
ɀ Nipple – malleable iron
ɀ Cover – sheet steel

Standard Finishes:
ɀ Feraloy and malleable iron – zinc
electroplate and aluminum acrylic paint
ɀ Sheet steel – electrogalvanized with
chromate finish

Size Ranges:
ɀ Conduit hubs – 3⁄4⍯ to 1⍯
ɀ Luminaire stem – 1⁄2⍯ and 3⁄4⍯
ɀ Luminaire weight – cushion type, 3 to 48
lbs.; ball type, 125 lbs.

Options:
ɀ The following special options are available
from factory by adding suffix to Cat. No.:
Suffix to be
Added to
Description
Cat. #
Suspension attachment for span wire
or threaded rod. See listings . . . . . . . . . . . . . S1

Suspension
Attachment

ALC

ALT

Ball

Ball

Luminaire
Stem
Size
1⁄2
3⁄4
3⁄4

Conduit
Size
3⁄4
3⁄4
1

Luminaire
Stem
Conduit
Size
Size
3⁄4
1⁄2
3⁄4
3⁄4
3⁄4
1

Cat. #
ALC21
ALC22
ALC32

Cushion

Cushion
Luminaire
Stem
Size
1⁄2
3⁄4
3⁄4

Conduit
Size
3⁄4
3⁄4
1

1⁄2

3⁄4

3⁄4

3⁄4

3⁄4

1

1⁄2

3⁄4

3⁄4

3⁄4

3⁄4

1

1⁄2

3⁄4

3⁄4

3⁄4

3⁄4

1

Luminaire
Weight
Lbs.
Cat. #
ALC214
3 to 6
ALC224
ALC324
6 to 12

12 to 24

24 to 48

Luminaire
Stem
Conduit
Size
Size
3⁄4
1⁄2
3⁄4
3⁄4
3⁄4
1

ALC218
ALC228
ALC328

1⁄2

3⁄4

3⁄4

3⁄4

3⁄4

1

ALC2116
ALC2216
ALC3216

1⁄2

3⁄4

3⁄4

3⁄4

3⁄4

1

ALC2132
ALC2232
ALC3232

1⁄2

3⁄4

3⁄4

3⁄4

3⁄4

1

For horizontal cable or vertical
support rod
AL hangers can be furnished with a loop
fastened to the top of the body to provide a
means for suspending luminaires from
vertical support rods or horizontal span wires.
The loop will take a wire or cable with a
maximum diameter of 3⁄8⍯. The boss on top of
the loop is tapped 3⁄8⍯-16 to accept a threaded
rod.

898

STIBOINFO((CRH:66008com:8L:898))
CH0 0 7 L - 4

US: 1-866-764-5454

Cat. #
ALT21
ALT22
ALT32

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Luminaire
Weight
Lbs.
Cat. #
ALT214
3 to 6
ALT224
ALT324
6 to 12

12 to 24

24 to 48

ALT218
ALT228
ALT328
ALT2116
ALT2216
ALT3216
ALT2132
ALT2232
ALT3232

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0899-3 Name: 8L-899

100:
DATE: JAN 19 2006

Time: 6:00:06 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

AHG – Class I, Div. 2, Groups A, B, C, D
Class II, Div. 2, F, G
Class III
Wet Locations NEMA 3, 3R
UNJ, UNJC – Class I, Div. 2, Groups A, B, C, D

AHG, UNJ and UNJC Flexible
Luminaire Hangers
For Pendant Mount

8L

Features:
ɀ For connection to conduit hub or hub cover
of supporting conduit fitting
ɀ For incandescent, H.I.D., and fluorescent
luminaires
ɀ Cushion support for conduit stem is a
universal joint permitting luminaire to swing
through an angle of 8 degrees in any
direction from the perpendicular
ɀ Gasketed by means of a durable neoprene
diaphragm which excludes moisture and dirt
from both luminaire and conduit system

Certifications and
Compliances:
Class I, Div. 2
Class II, Div. 2
Class III
Wet Locations
NEMA 3,3R

Standard Materials:
ɀ Housing: top cap – malleable iron; bottom
cap – Feraloy® iron alloy
ɀ Luminaire stem support – Feraloy iron alloy

Standard Finishes:
ɀ Feraloy iron alloy and malleable iron –
electrogalvanized and aluminum acrylic paint

Size Ranges:
3⁄4⍯

ɀ Male nipple –
ɀ Luminaire stem – 3⁄4⍯
ɀ Luminaire weight – 4 to 30 lbs.

AHG
Cushion Vaportight for Class I,
Div. 2; Class II, Div. 2; Class III
Luminaire
Stem
Size*
3⁄4
3⁄4
3⁄4

Male
Nipple
Size*
3⁄4
3⁄4
3⁄4

Luminaire
Weight
Lbs.
4 to 8
8 to 16
16 to 30

Cat. #
AHG22103
AHG22104
AHG22111

Features:
ɀ For connection to conduit hub or hub cover
of supporting conduit fitting
ɀ For incandescent, H.I.D., and fluorescent
luminaires
ɀ Supporting nipple, ball or cushion type, is a
universal joint permitting luminaires to swing
through an angle of 20 degrees in any
direction from the perpendicular

Standard Materials:
ɀ Body and nipple – malleable iron
ɀ Clamp – copper-free aluminum

Standard Finishes:
ɀ Malleable iron – electrogalvanized and
aluminum acrylic paint
ɀ Copper-free aluminum – natural finish

Size Ranges:
ɀ Male nipple – 1⁄2⍯ and 3⁄4⍯
ɀ Luminaire stem – 1⁄2⍯ and 3⁄4⍯
ɀ Luminaire weight: cushion type – 6 to 48
lbs.; ball type – 125 lbs.

Certifications and
Compliances:

UNJ
Ball
Luminaire
Stem
Size
1⁄2
3⁄4

Male
Nipple
Size
Cat. #
1⁄2
UNJ1
3⁄4
UNJ2

ɀ NEC: Class I, Div. 2.

UNJC
Cushion
Luminaire
Stem
Size*
3⁄4
3⁄4
1⁄2
3⁄4

Male
Nipple
Size*
3⁄4
3⁄4
1⁄2
3⁄4

Luminaire
Weight
Lbs.
6 to 12
12 to 24
24 to 48

Cat. #
UNJC28
UNJC216
UNJC132
UNJC232

* 1⁄2⍯ connection can be made by using reducers.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8L:899))
CH0 0 7 L - 6

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

899

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0900-2 Name: 8L-900

8L

100:
DATE: JAN 19 2006

Time: 6:00:07 PM Operator: JB

COLOR: CMYK

TCP: 15001

Flexible Luminaire Hangers
For Pendant Mount
Dimensions

AL Series
UNJ

UNJC
Cushion

Ball

AHG

900

STIBOINFO((CRH:66008com:8L:900))
CH0 0 7 L - 7

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0901-3 Name: 8L-901

100:
DATE: JAN 19 2006

Time: 6:00:08 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Class I, Div. 2, Groups A, B, C, D

ARB and GS Flexible
Luminaire Hangers

8L

For Pendant Mount

Features:

For GRF and VXF outlet boxes only

ɀ Available in two styles – one for direct
attachment to GRF cast outlet boxes by 4
screws, the other for direct attachment to 4⍯
octagonal stamped steel outlet boxes by 2
screws. For incandescent, H.I.D. and
fluorescent luminaires
ɀ Both styles available with ball or cushion
support for conduit stem to permit luminaire
swing in any direction. Ball type provides 11
degree swing, cushion type 8 degree swing
from the perpendicular
ɀ Gasketed cushion hangers for GRF are
provided with a durable neoprene diaphragm
which excludes moisture and dirt from both
luminaire and conduit system

Outlet Boxes
Ball

Ball

Cushion

Luminaire
Stem
Description Size
1⁄2
Surface
1⁄2
Flush
Surface
125

ɀ Mounting plate: for GRF – Feraloy® iron
alloy; for 4⍯ outlet boxes – sheet steel
ɀ Hanger body and luminaire stem support –
Feraloy iron alloy

Luminaire
Weight
(Max.)
Cat. #
125
ARB62
125
ARB67
3⁄4
ARB662

Cushion Surface
Luminaire
Stem
Size
1⁄2
1⁄2
1⁄2

Standard Materials:

Luminaire
Weight
Lbs.
Cat. #
4 to 8
ARB82
8 to 16 ARB102
16 to 30 ARB122

Cushion Surface – Vaportight with
Neoprene Diaphragm

Standard Finishes:
ɀ Feraloy – electrogalvanized and aluminum
acrylic paint
ɀ Sheet steel – electrogalvanized with
chromate finish

ARB Fits GRF and VXF

For GRF and VXF outlet boxes and 4⍯
octagonal outlet boxes

Luminaire
Stem
Size
1⁄2
1⁄2
1⁄2

Luminaire
Weight
Lbs.
Cat. #
4 to 8
ARB821
8 to 16 ARB1021
16 to 30 ARB1221

ARB Fits GRF, VXF and 4⍯ Outlet

Size Ranges:

Boxes
Ball

ɀ Luminaire stem – 1⁄2⍯ and 3⁄4⍯
ɀ Luminaire weight: cushion type – 4 to 30
lbs.; ball type – 125 lbs. (ARB6 and ARB2
maximum weight 60 lbs.)
Ball

Cushion

Luminaire
Stem
Size
1⁄2
3⁄4

Luminaire
Weight
(Max.)
60
60

Cat. #
ARB6
ARB2

Luminaire
Weight
Lbs.
4 to 8
8 to 16
16 to 30

Cat. #
ARB8
ARB10
ARB12

Cushion
Luminaire
Stem
Size
1⁄2
1⁄2
1⁄2

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8L:901))
CH0 0 7 L - 9

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

901

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0902-2 Name: 8L-902

8L

100:
DATE: JAN 19 2006

Time: 6:00:09 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. l, Div. 2 Groups A, B, C, D

UNE, UNH and UNHC Flexible
Luminaire Hangers
For Pendant Mount

The following applies to all items on this
page:

Application:

ɀ Provides a simple, inexpensive, quick
disconnect method for hanging pendant
luminaires. For incandescent, H.I.D. and
fluorescent luminaires
ɀ Permits free swing in any direction to
prevent damage to luminaire stem. Cushion
style provides additional protection from
vibration to prolong lamp life

Features:

ɀ Female hooks and loops are used with rigid
conduit luminaire stems to suspend
luminaires. They may also be used with male
hooks and loops, threaded into a conduit
outlet hub.
ɀ All hooks and loops are provided with
openings for passage of luminaire wires.
Luminaire, conduit stem and hook or loop
can be assembled and wired at the work
bench. The assembly is then hung on the
fixed hook and connection made.
ɀ For ease of relamping and maintenance,
the outlet fitting can be equipped with an
attachment plug receptacle cover and a
matching plug cap used with the luminaire
assembly. For permanent wiring a wire hole
cover may be used.
Applicable to UNE and UNH (upper
listings) only:

Male

Female

Male

UNH

Female
UNE

UNE and UNH Flexible Luminaire Hangers
For Pendant Mount
Type

Style
Male

Luminaire
Stem
Size
1⁄2
3⁄4

Luminaire
Weight
Lbs.
125
125

Cat. #
UNH16
UNH26

125
125

UNH1
UNH2

125
125

UNE16
UNE26

125
125

UNE1
UNE2

UNH
Female
Male

1⁄2
3⁄4
1⁄2
3⁄4

UNE
Female

Features:

1⁄2
3⁄4

ɀ Shape of hooks is such that accidental
disengagement is impossible
ɀ Diameter of wire opening 1⁄2⍯

Standard Materials:
ɀ Malleable iron

Standard Finishes:

ɀ Cadmium electrogalvanized and aluminum
acrylic paint

Size Ranges:

ɀ Luminaire stem or hub – 1⁄2⍯ and 3⁄4⍯
ɀ Luminaire weight – 125 lbs.
Applicable to UNH and UNHC (lower
listings) only:

Features:

ɀ Hooks are shaped to permit easy
installation of large heavy luminaires, such as
H.I.D. and fluorescent units
ɀ Diameter of wire opening 5⁄8⍯

Standard Materials:
ɀ Copper-free aluminum

Female

UNH and UNHC Flexible Luminaire Hangers
Type
UNH

Style
Female

UNHC

Standard Finishes:

Female Cushion

Female
Cushion

Luminaire
Stem
Size

Luminaire
Weight
Lbs.

Cat. #

1⁄2

125

UNH182

3⁄4

12 to 24
24 to 48
48 to 64

UNHC216
UNHC232
UNHC264

3⁄4
3⁄4

ɀ Natural

Size Ranges:

ɀ Luminaire stem – 1⁄2⍯ and 3⁄4⍯
ɀ Luminaire weight: cushion type – 12 to
64 lbs.; plain type – 125 lbs.

902

STIBOINFO((CRH:66008com:8L:902))
CH0 7 L - 1 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0903-2 Name: 8L-903

100:
DATE: JAN 19 2006

Time: 6:00:11 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

No Wireway Opening

UNHC Flexible Luminaire Hangers

8L

For Support Only
CHS Conduit Clamp; UNH Conduit Hook;
For Pendant Mount Fluorescent Luminaires
Application:
ɀ Used for support of pendant fluorescent
luminaires
ɀ UNHC provides cushion support for
luminaires suspended by 1⁄4⍯ or 5⁄16⍯ threaded
rod, and is used with the ring of CHS conduit
clamps
ɀ UNH hook provides an extremely simple
means of conduit suspension for the unwired
end of a fluorescent luminaire, as it merely
hooks over the horizontal supporting conduit

Features:
ɀ The bushing in UNHC cushion hangers is
tapped for both 1⁄4⍯ and 5⁄16⍯ suspension rod,
with the lower half tapped 5⁄16⍯. Either size rod
can be used without reversing the bushing
ɀ CHS conduit clamp firmly grips the conduit
and the ring at bottom accepts either a
hooked rod or the UNHC cushion hanger for
threaded rod. Will also accept UNH and
UNHC hangers for conduit stem listed on the
preceding page.
ɀ The UNH conduit hook fits over conduit up
to and including 1⍯ and has a hub for
attachment of a 1⁄2⍯ conduit stem

Clamp

UNHC Cushion Luminaire
Hangers
Luminaire
Weight
Lbs.
12 to 24
24 to 48
48 to 64

Support
Rod Tap
1⁄4⍯-20
and
5⁄16⍯-18

Cat. #
UNHC2816
UNHC2832
UNHC2864

Hook

CHS Conduit Clamp and
UNH Hook
Conduit
Size
1⁄2
3⁄4
1

Clamp
Hook
Cat. #
Cat. #
CHS1437
CHS2437 ៑ UNH13
CHS3437

Hook
Hub
Size
1⁄2

Standard Materials:
ɀ UNHC – copper-free aluminum
ɀ CHS-body – malleable iron; clamp –
copper-free aluminum; ring – steel wire
ɀ UNH – Feraloy® iron alloy

Standard Finishes:
ɀ Copper-free aluminum – natural finish
ɀ Feraloy and malleable iron –
electrogalvanized and aluminum acrylic paint
ɀ Steel wire – electrogalvanized with
chromate finish

Size Ranges:
ɀ Luminaire stem (UNH) – 1⁄2⍯
ɀ Conduit (CHS): 1⁄2⍯ to 1⍯
ɀ Luminaire weight: UNHC cushion – 12 to
64 lbs.; CHS, UNH – 125 lbs.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8L:903))
CH0 7 L - 1 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

903

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0904-2 Name: 8L-904

8L

100:
DATE: JAN 19 2006

Time: 6:00:42 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

FHM Power Hook
Luminaire Hangers
For Pendant Luminaires

Features:
ɀ For mounting H.I.D. type luminaires in
non-hazardous locations
ɀ Power hook housing has two 3⁄4⍯ through
feed hubs and one 3⁄4⍯ hub on the top for
pendant mounting. Through feed hubs are
furnished with flush plugs
ɀ Cast mounting lugs are provided for direct
ceiling mounting
ɀ Housing contains a roomy 15 cu. in.
splicing chamber and interlocking type
receptacle with leads
ɀ Plugs and receptacles are interlocking type
to prevent accidental disengagement. When
plug is inserted, hook is blocked and
luminaire assembly cannot be removed. To
service the luminaire, pull the plug, unhook
the loop luminaire assembly and take it to a
convenient servicing area
ɀ Loop can move a maximum of 30°, allowing
the power hook to be mounted on a canted
ceiling. The luminaire assembly will hang true
to the vertical
ɀ Loop and hook are shaped for self
alignment and resist twisting of luminaire by
gusts of wind or light drafts
ɀ Supporting loop is furnished with 16⍯ of
#16-3/C type SO cord and an interlocking
type plug

FHM
For H.I.D. Type Luminaires
with voltages up to 480 volts
Loop
Plain

Luminaire
Stem*
3⁄4

Hubs*
3⁄4

Luminaire
Weight
Lbs.
125

Cat. #
FHM201

Standard Materials:
ɀ Power hook body – copper-free aluminum
ɀ Access cover – zinc plated cold rolled steel
ɀ Loop – copper-free aluminum

Plain
* 1⁄2⍯ connection can be obtained by using reducers

Standard Finishes:
ɀ Copper-free aluminum – natural finish
ɀ Steel – electrogalvanized with chromate
finish

Dimensions

Size Ranges:
ɀ Hubs – 3⁄4⍯
ɀ Luminaire weights: loop – up to 125 lbs.;
ɀ Loop luminaire stem size – 3⁄4⍯

Electrical Rating Ranges:
ɀ 480 volts, 14 amps, 2 wire, 3 pole

Certifications and
Compliances:
ɀ Meet UL and NEMA requirements for the
listed electrical ratings

Plain

904

STIBOINFO((CRH:66008com:8L:904))
CH0 0 7 L - 8

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0905-2 Name: 8L-905

100:
DATE: JAN 19 2006

Time: 6:00:43 PM Operator: JB

COLOR: CMYK

Cl. I, Div. 1 & 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

ECHF Flexible Luminaire
Supports
For Pendant Mount

TCP: 15001

Typedriver Name: TS name csm no.: 100

Explosionproof
Dust-Ignitionproof

8L

Application:
ECHF series flexible luminaire supports are
used in hazardous locations:
ɀ where a luminaire must hang more than 12⍯
from its supporting junction box (as specified
by NEC Article 501 and CEC Part I Section 18)
ɀ to assure that luminaires hang plumb and
will swing freely if accidentally struck.
Prevents damage to luminaire and
supporting outlet fitting

Features:
ɀ Complies with NEC Article 501/CEC Part I
Section 18
ɀ Free swinging in any direction through a
large arc
ɀ Good electrical continuity – no bonding
jumpers needed
ɀ Watertight construction
ɀ Insulating liner of asphalt impregnated fiber
to protect conductors
ɀ Constructed to reinforced flexible metal
hose
ɀ Two female end fittings, each with a
removable short nipple
ɀ Nipples fit set screw type luminaire hubs
ɀ Female end fittings are equipped with set
screws to prevent turning during relamping
and loosening of fitting with vibrations

ECHF
Description
Flexible
Nipple
Length
Size
1⁄2
4
3⁄4
6
8
10
12
15
18

1⁄2
3⁄4
1⁄2
3⁄4
1⁄2
3⁄4
1⁄2
3⁄4
1⁄2
3⁄4
1⁄2
3⁄4

Overall
Length
10
10

Cat. #
ECHF14
ECHF24

12
12

ECHF16
ECHF26

14
14

ECHF18
ECHF28

16
16

ECHF110
ECHF210

18
18

ECHF112
ECHF212

21
21

ECHF115
ECHF215

24
24

ECHF118
ECHF218

Standard Materials:
ɀ Inner core – brass
ɀ Outer braid – bronze
ɀ End fittings – bronze
ɀ End fittings – brass (CSA certified units)

Standard Finishes:
ɀ Brass and bronze – natural

Options:
Suffix to be
Added to
Description
Cat. #
Material – stainless steel hose and
end fittings . . . . . . . . . . . . . . . . . . . . . . . . . . S516
Finish – flexible neoprene
protective coating. . . . . . . . . . . . . . . . . . . . S758
Special lengths and sizes
available . . . . . . . . . . . . . . Detailed information
on request

Size Ranges:
ɀ Flexible length – 4⍯ to 18⍯
ɀ Nipple size – 1⁄2⍯ and 3⁄4⍯ (see ‘‘Options’’)
ɀ Luminaire weight – up to 125 lbs.

Certifications and
Compliances:
ɀ NEC/CEC: Class I, Groups A, B, C, D
Class II, Groups E, F, G
Class III
ɀ UL Standard: 886
ɀ CSA Standard: C22.2 No. 30

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8L:905))
CH0 7 L - 1 2

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

905

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0906-2 Name: 8L-906

8L

100:
DATE: JAN 19 2006

Time: 6:00:44 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 & 2, Groups A*, B*, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

EAHC and EFHC
Luminaire Hangers
For Pendant Mount

Explosionproof
Dust-Ignitionproof

Application:
EAHC and EFHC luminaire hangers are for
use in hazardous areas to:
ɀ suspend explosionproof pendant
luminaires from the conduit system
ɀ function as both conduit outlet box and
luminaire hanger

Mounting Strap
Mounting strap can be furnished to fasten
luminaire hangers to mounting surface,
independent of conduit straps. To order, add
suffix S294 to EAHC or EFHC Cat. No.

Features:
ɀ Through feed hubs are provided for
threading the conduit directly into the hanger
body
ɀ Has large threaded cover for accessibility
and ease of wiring
ɀ Bottom hub, threaded or union style, is
equipped with set screws to securely lock
luminaire stem in place. Takes conduit stem
or EC flexible luminaire hanger for stems
longer than 12⍯ (in compliance with NEC
Article 501 and CEC Part I Section 18)

With union hub

Suspension Attachment

Standard Materials:
ɀ Bodies – Feraloy® iron alloy
ɀ Covers – copper-free aluminum

With threaded hub

Standard Finishes:
ɀ Feraloy – electrogalvanized and aluminum
acrylic paint
ɀ Copper-free aluminum – natural

Options:
Suffix to be
Added to
Description
Cat. #
Finish – Corro-free TM epoxy enamel . . . . S752
Suspension attachment for span
wire or threaded rod – see listings . . . . . . . . S1
Mounting strap – see listings . . . . . . . . . . S294

Size Ranges:
ɀ Conduit hubs – 3⁄4⍯ and 1⍯
ɀ Luminaire stem – 1⁄2⍯ and 3⁄4⍯
ɀ Luminaire weight – 125 lbs.

EAHC and EFHC hangers can be furnished
with a loop fastened to the top of the body to
suspend luminaire and conduit from vertical
support rods or horizontal span wires. The
loop will take a wire or cable with a maximum
diameter of 3⁄8⍯. The boss on top of the loop is
tapped 3⁄8⍯-16 to accept a threaded rod. To
order, add suffix S1 to Cat. No.

EAHC*
Luminaire
Hub Stem
Size Size
1⁄2
3⁄4
3⁄4
1⁄2
1
3⁄4

Threaded
Hub for
Luminaire
Stem Cat. #
EAHC2701
EAHC2702
EAHC3701
EAHC3702

Union
Hub for
Luminaire
Stem Cat. #
EAHC2601
EAHC2602
EAHC3601
EAHC3602

EFHC2701
EFHC2702
EFHC3701
EFHC3702

EFHC2601
EFHC2602
EFHC3601
EFHC3602

EFHC
3⁄4

1

1⁄2
3⁄4
1⁄2
3⁄4

*EAHC only

Certifications and
Compliances:
ɀ NEC/CEC:
EAHC –
Class I, Groups A, B, C, D
Class II, Groups E, F, G
Class III
EFHC –
Class I, Groups C, D
Class II, Groups E, F, G
Class III
ɀ UL Standard: 886
ɀ CSA Standard: C22.2 No. 30

906

STIBOINFO((CRH:66008com:8L:906))
CH0 7 L - 1 5

Dimensions

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0907-2 Name: 8L-907

DATE: JAN 19 2006

Time: 6:00:45 PM Operator: JB

COLOR: CMYK

Cl. I, Div. 1 and 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

EFH Flexible Cushion
Luminaire Hangers
For Pendant Mount

TCP: 15001

Typedriver Name: TS name csm no.: 100

Explosionproof
Dust-Ignitionproof

8L

Application:
EFH flexible cushion luminaire
hangers are used in hazardous
locations:
ɀ where a luminaire must hang
more than 12⍯ from its supporting
junction box (as required by NEC
Article 501 and CEC Part I
Section 18)
ɀ to assure that luminaires hang
plumb and will swing freely if
accidentally struck. Prevents
damage to luminaire, stem and
supporting outlet box
ɀ to provide a cushion support,
prolonging lamp life and
protecting the luminaire from
shock and vibration. For
luminaires weighing up to 65 lbs.

Features:
ɀ Complies with NEC Article 501
and CEC Part I Section 18
ɀ Free swinging in any direction
through an angle of 15 degrees
from perpendicular
ɀ Weight of luminaire is
supported by a high-strength
brass bellows and a stainless
steel cushioning spring
ɀ Two part assembly consisting
of luminaire hanger cover and
CPS12 outlet box. Provides a
wide variety of conduit
arrangements. A set screw locks
the conduit stem in place

Standard Materials:
ɀ Feraloy® iron alloy

Standard Finishes:
ɀ Electrogalvanized and
aluminum acrylic paint

Size Ranges:
ɀ Conduit hubs – 3⁄4⍯ with 3⁄4⍯ to
1⁄2⍯ reducers
ɀ Luminaire stem – 1⁄2⍯ and 3⁄4⍯
ɀ Luminaire weight – 65 lbs. max.

EFHX
Body
Hub
Size‡
1⁄2
1⁄2

Luminaire
Stem
Size
1⁄2

and 3⁄4
and 3⁄4

3⁄4

With
Mtg. Feet
Cat. #
EFHX111
EFHX221

Cushion
Luminaire
Hanger Only
Stem
Size
1⁄2
3⁄4

Cat. #
EFH01
EFH02

‡ Furnished with four 3⁄4⍯ standard taper tapped, integrally
bushed hubs. Each hub as a 3⁄4⍯ to 1⁄2⍯ reducer. Three hubs
are plugged.

Dimensions

Certifications and
Compliances:
ɀ NEC/CEC: Class I,
Groups C, D
Class II,
Groups E, F, G
Class III
ɀ UL Standard: 886
ɀ CSA Standard: C22.2 No. 30

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8L:907))
CH0 7 L - 1 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

907

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0908-2 Name: 8L-908

100:
DATE: JAN 19 2006

Time: 6:00:46 PM Operator: JB

Condulet® Conduit Outlet Boxes
with Covers

8L

COLOR: CMYK

TCP: 15001

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

Typedriver Name: TS name csm no.: 100

Explosionproof
Dust-Ignitionproof

Application:
CPS series conduit outlet boxes
are installed in conduit systems in
hazardous areas to:
ɀ protect conductors in threaded
rigid conduit
ɀ act as pull and splice boxes
ɀ change conduit direction
ɀ interconnect lengths of conduit
ɀ act as luminaire hangers with
hub covers
ɀ provide access to conductors
for maintenance and future
system changes

Features:
CPS conduit outlet boxes have:
ɀ two types of cover:
– blank for splice or pull box use
– threaded hub for mounting
luminaires
ɀ wide, accurately machined
body and cover mating surfaces,
to insure flametight joint
ɀ blind tapped holes for cover
screws to further insure
flametightness
ɀ removable mounting feet for
flush or surface mounting to wall
or ceiling

Standard Materials:
ɀ Feraloy iron alloy
®

Standard Finishes:

Box with Hub Cover

Box with Blank Cover

Hub Size

Hub
Size
1⁄2 and 3⁄4

Body‡
1⁄2 and 3⁄4
1⁄2 and 3⁄4

Cover
1⁄2
3⁄4

Cat. #
CPS12021
CPS12022

Hub Covers
Hub
Size
1⁄2
3⁄4

Body
Hub
Size‡
1⁄2 and 3⁄4

‡ Furnished with four 3⁄4⍯ standard taper tapped, integrally bushed hubs.

Options:
ɀ Corro-free epoxy powder coat
. . . . . . . . . . . . . . . . . . . . Information
available on request

Cat. #
CPS021
CPS022

Cat. #
CPS12

ɀ Electrogalvanized and
aluminum acrylic paint
TM

Cat. #
CPS12026

Each hub has a 3⁄4⍯ to 1⁄2⍯ reducer. Three hubs are plugged.

Dimensions

Certifications and
Compliances:
ɀ NEC/CEC: Class I, Groups C, D
Class II,
Groups E, F, G
Class III
ɀ UL Standard: 886
ɀ CSA Standard: C22.2 No. 30

908

STIBOINFO((CRH:66008com:8L:908))
CH0 7 L - 1 8

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0909-2 Name: 8L-909

DATE: JAN 19 2006

Time: 6:00:47 PM Operator: JB

COLOR: CMYK

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

GUF Outlet Bodies and
Luminaire Hanger Covers

TCP: 15001

Typedriver Name: TS name csm no.: 100

Explosionproof
Dust-Ignitionproof

8L

Luminaire Hanger Covers
For GUA and GUF Series Junction Boxes

Nom. Dia. Luminaire Luminaire Luminaire covers Nipple covers
Cover
Stem
canopies union hub
Opening
Size
Cat. #
Cat. #
Cat. #
3⁄4
GUA068 GUA0687
GUA0672
3

GUFX
Hub
Size
1⁄2
3⁄4

Cat. #
GUFX160
GUFX260

Dimensions
Hanger Covers

Dimensions
GUF Series

GUA 068

GUA 0687
Hub
Size
1⁄2
3⁄4
1

a
31⁄2
31⁄2
31⁄2

b
2
2
23⁄8

c
3
3
3

d

e

f

5⁄8

7⁄8

5⁄16

3⁄4

7⁄8
1

5⁄16
5⁄16

7⁄8

g
53⁄8
53⁄8
53⁄8

GUA 0671

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8L:909))
CH0 7 L - 1 4

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

909

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0910-2 Name: 8L-910

8L

100:
DATE: JAN 19 2006

Time: 6:00:49 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

GUA Series Outlet Bodies

Explosionproof
Dust-Ignitionproof

Application:
GUA, GUF and GUJ outlet bodies are used:
ɀ with luminaire canopies, union hub and
nipple covers for mounting EVA, EVM, EVLP,
and EVF luminaires

Features:
ɀ A threaded cover opening in the side of the
canopy permits access to the interior for
making splices or taps
ɀ The luminaire with its conduit stem and
canopy is wired before installation, which
eliminates wire twisting when the canopy is
screwed into the outlet body
ɀ Union hub covers permits the cover to be
screwed into the body without twisting wire
leads
ɀ All covers have set screws to lock the
conduit stem or EC series flexible luminaire
support firmly to the cover

GUA
Hub
Size
1⁄2
3⁄4
1

GUAT

Cat. #
GUA160
GUA260
GUA360

Hub
Size
1⁄2
3⁄4
1

Cat. #
GUAT160
GUAT260
GUAT360

Standard Materials:
Outlet bodies:
ɀ GUA Series – Feraloy iron alloy
ɀ GUFX – Copper-free aluminum
Luminaire hanger covers:
ɀ GUA068 – Feraloy iron alloy
ɀ GUA0687, GUA0672 – Copper-free
aluminum

Standard Finishes:
ɀ Feraloy iron alloy – electrogalvanized and
aluminum acrylic paint
ɀ Copper-free aluminum – natural

GUAC
Hub
Size
1⁄2
3⁄4
1

Cat. #
GUAC160
GUAC260
GUAC360

GUAX
Hub
Size
1⁄2
3⁄4
1

Options:
Suffix to be
Added to
Description
Cat. #
Finish – Corro-free TM epoxy enamel . . . . S752

Cat. #
GUAX160
GUAX260
GUAX360

Size Ranges:
ɀ Bodies – 1⁄2⍯ to 1⍯ hubs
ɀ Canopies – 1⁄2⍯, 3⁄4⍯ and 11⁄4⍯ luminaire stem
ɀ Union hub and nipple covers – 1⁄2⍯ and 3⁄4⍯
luminaire stem

Certifications and
Compliances:
ɀ NEC/CEC: Class I, Groups C, D
Class II, Groups E, F, G
Class III
ɀ UL Standard: 886
ɀ CSA Standard: C22.2 No. 30

GUAL
Hub
Size
1⁄2
3⁄4
1

Cat. #
GUAL160
GUAL260
GUAL360

Dimensions
GUA Series

Hub
Size
1⁄2
3⁄4
1

910

STIBOINFO((CRH:66008com:8L:910))
CH0 7 L - 1 3

US: 1-866-764-5454

CAN: 1-800-265-0502

a
31⁄2
31⁄2
31⁄2

b
2
2
25⁄16

c
3
3
3

Copyright© 2006 Cooper Crouse-Hinds

d
5⁄8
3⁄4
7⁄8

e
7⁄8
7⁄8
1

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0911-2 Name: 8L-911

100:
DATE: JAN 19 2006

Time: 6:01:22 PM Operator: JB

COLOR: CMYK

TCP: 15001

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III

UNR Adjustable Luminaire
Hangers; COUP Locking
Couplings

Typedriver Name: TS name csm no.: 100

Explosionproof
Dust-Ignitionproof

8L

For Pendant Mount
Application:

Standard Finishes:

UNR adjustable luminaire hangers are used
in hazardous areas to:
ɀ mount between a luminaire and its outlet
box so that the luminaire can be adjusted
within the range of 0 degrees to 90 degrees
ɀ permit pendant type luminaires to illuminate
vertical surfaces such as a control board
ɀ hang luminaires plumb when the
supporting outlet box is not horizontal

ɀ Electrogalvanized and aluminum acrylic
paint

Features:

ɀ NEC: Class I, Groups C, D
Class II, Groups E, F, G
Class III
ɀ UL Standard: 886

The luminaire is nippled onto one end of the
UNR, and the other end of the UNR is nippled
into the support outlet box
ɀ Set screws are located on each end to lock
the nipples in place to prevent loosening in
relamping or from vibration
ɀ Adjustment of UNR to the angle setting
needed provides for the desired angle of the
luminaire
ɀ Degree markings are cast into the UNR
ɀ Two set screws and a large stud and nut
are provided, which are tightened to clamp
the unit rigid

Size Ranges:
ɀ Hub – 3⁄4⍯
ɀ Luminaire weight – 125 lbs.

Certifications and
Compliances:

UNR
Adjustable
Luminaire Hanger
Hub
Size
3⁄4

Angle
Adjustment Cat. #
0° to 90°
UNR29

Dimensions

Standard Materials:
ɀ Feraloy® iron alloy

Application:

Standard Finishes:

COUP locking couplings are used in both
hazardous and non-hazardous areas to:
ɀ lock a luminaire conduit stem into a conduit
hub to prevent the conduit stem from
loosening when the luminaire is relamped
and torque transferred to luminaire stem
ɀ prevent loosening of luminaire stem due to
vibration
ɀ hang pendant type luminaires from
standard cast outlet boxes which do not have
set screws in the hub where the luminaire
stem is attached

ɀ Electrogalvanized and aluminum acrylic
paint

Size Ranges:
ɀ Hub size – 1⁄2⍯ to 1⍯
ɀ Stem size – 1⁄2⍯ and 3⁄4⍯

Certifications and
Compliances:
ɀ UL Standard: 886

Features:

COUP

ɀ The large end is slipped over the cast hub
and the set screws tightened. The luminaire
stem is slipped through the small end and
threaded securely into the cast hub. The set
screws in the small end are then tightened,
thereby preventing the stem from turning
ɀ Permits support of luminaire from conduit
hub of a hazardous location outlet body

Locking
Couplings
Hub
Size
1⁄2
3⁄4
3⁄4
1

Standard Materials:
ɀ Feraloy® iron alloy

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8L:911))
CH0 7 L - 1 6

CAN: 1-800-265-0502

Stem
Size
1⁄2
1⁄2
3⁄4
3⁄4

Copyright© 2006 Cooper Crouse-Hinds

Cat. #
COUP101
COUP201
COUP202
COUP302

911

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0912-1 Name: Note Page-912

DATE: JAN 19 2006

Time: 6:01:23 PM Operator: JB

COLOR: CMYK

Notes Page

912

STIBOINFO((CRH:66008com::912))
CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0913-3 Name: 9L-913

100:
DATE: JAN 19 2006

Time: 6:01:24 PM Operator: RB

COLOR: CMYK

TCP: 15001

Portable Lighting
Hazardous and Non-Hazardous

Typedriver Name: TS name csm no.: 100

9L

Description

Page No.

Application/Selection

914

Handlamps
VS Series Incandescent
EVH Series Incandescent
EVH Series Fluorescent

915
916
921, 922

Portable Floodlights
RCDER Series Incandescent
EVP Series H.I.D.

917, 918
919, 920

Worklights
EVH Series Fluorescent

US: 1-866-764-5454

STIBOINFO((CRH:66008com:9L:913))
CH0 0 0 0 8 L

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

921, 922

913

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0914-2 Name: 9L-914

9L

100:
DATE: JAN 19 2006

Time: 6:01:24 PM Operator: JB

COLOR: CMYK

TCP: 15001

Portable Lighting
Hazardous and Non-Hazardous Locations
Application and Selection
Quick Selector Chart

Applications:
Portable luminaires and accessories can be
used:
ɀ in areas made hazardous by the abnormal
presence of flammable gases and vapors,
combustible dusts or easily ignitable fibers
and flyings.
ɀ in areas where combustible dusts and
flammable gases are present simultaneously.
ɀ in aircraft manufacturing and maintenance
facilities, shipyards, paint spray booths,
refueling depots, storage tank cleanings,
railcar manufacturing and maintenance
facilities, refineries, chemical and
petrochemical plants, textile mills, grain
elevators, pharmaceutical plants, sewage
treatment plants and wastewater treatment
plants.
ɀ during plant ‘shut downs’ for maintenance
and installation requirements.
ɀ in any adverse environment where portable
lighting is preferred or required.
ɀ in locations where fixed lighting is not
practical.
ɀ for task oriented lighting.
ɀ for emergency lighting applications.
ɀ when inspecting aircraft wing tanks, vats,
process vessels, fuel tanks, etc. (handlamps).

Considerations for
Selection:
Environmental:
ɀ What is the hazardous area classification
(NEC/CEC) of the location in which the
luminaires will be installed?
ɀ What wattages and light source (ie.
fluorescent) will provide the desired light
levels?
ɀ Type of luminaire required: handlamp,
portable flood or other special requirements.

Table 500-3(d)
Identification Numbers.
Maximum
Temperature
Deg. C
Deg. F
450
842
300
572
280
536
260
500
230
446
215
419
200
392
180
356
165
329
160
320
135
275
120
248
100
212
85
185

Identification
Number
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

Quick Selector Chart
Luminaire

Lamp
Watts

Volts

EVH Handlamp
(Incandescent)

Cl. I, Groups C and D
Cl. II, Group G
Cl. III

100 max.

250 vac

EVH Handlamp
(Fluorescent)

Cl. I, Groups C and D
Cl. II, Groups E, F, G
Cl. III

13, 15

120, 220-50

EVP

Cl. I, Groups C and D
Cl. II, Groups F and G
Cl. III

35-150

120, 277, 347

RCDER

Cl. I, Groups C and D

150-500

VS

Non-Hazardous areas

100 max.

914

STIBOINFO((CRH:66008com:9L:914))
CH0 0 8 L - 0

NEC Hazardous
Area
Compliances

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0915-6 Name: 9L-915

100:
DATE: JAN 19 2006

Time: 6:01:25 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Weather Resistant

VS Portable Hand Lamps

9L

Incandescent
Accessories

Glass Globes

Application:
The incandescent VS portable hand lamps
are used:
ɀ in wet or corrosive locations to exclude
moisture, dirt, corrosive chemicals, etc.
ɀ where an incandescent lamp of up to 100
watts is required in a portable hand lamp

Polycarbonate
Globes

Features:
ɀ Enclosed and gasketed
ɀ Flexible cord or cable is attached through a
watertight gland in the handle
ɀ Is of rugged construction
ɀ Clamp type guard available
ɀ Provision is made in the lamp receptacle for
a third conductor to ground all non-currentcarrying metal parts

Description
Clear Glass,
(Heat
Resisting)
Clear,
Polycarbonate,
Plain

Standard Materials:
ɀ Handle – molded rubber
ɀ Globe – clear, plain glass
ɀ Guard – cast aluminum or steel wire

(No Cable Included)

Standard Finishes:
ɀ Handle – Natural
ɀ Guard – Zinc plated

Options:
ɀ Materials: heat resistant glass globe;
polycarbonate globe

Size Ranges:

Globe
Length
67⁄8

Max
Lamp
Size
100 W
A-23†

Cord
Dia.
.125 to
.625

Maximum
Lamp Size

Cat. #

100W,
A-23 – 67⁄8⍯†

V63

75W,
A-21⍯†

V470

Size
67⁄8 globe

Cat. #
VS97

Rubber
Cat. #
VS30

Note: Furnished with clear globe, wire guard
and 4 rubber bushings.

ɀ Up to 100 watt, A-23 lamp
ɀ .250 to .625 cord O.D.

Certifications and
Compliances:
ɀ Weather resistant
ɀ UL Standard: 298

Guards
Description
Steel Wire

(Note: CEC/CSA Certified VS handlamps - Cooper CrouseHinds Canada fixtures only.)

Lamp
Receptacle
(medium base)
Description
Composition
keyless

Size
660W,
600V

Cat. #
GS156

Cord Gland
Bushings
Description Size
Cat. #
Rubber
.125 to .250 Cord BUSH92
.250 to .375 Cord BUSH93
.375 to .500 Cord BUSH 94
.500 to .625 Cord BUSH05
† Will take lamps with maximum dimensions of 61⁄2⍯ long and
27⁄8⍯ diameter.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:9L:915))
CH0 0 8 L - 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

915

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0916-2 Name: 9L-916

9L

100:
DATE: JAN 19 2006

Time: 6:01:27 PM Operator: JB

EVH Portable Handlamp

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1 & 2, Group G
Cl. III
Cl. I, Zone 1 IIB

Application:
EVH106 is used:
ɀ as a portable handlamp in hazardous areas
ɀ in inspecting aircraft wing tanks, vats,
process vessels, fuel tanks, etc.

Features:
ɀ Pressure connector terminals for portable
cord
ɀ Light weight – 41⁄4 lbs.
ɀ Designed for rough service – swivel hook,
ease in relamping

Standard Materials:
ɀ Guard and globe holder – copper-free
aluminum
ɀ Handle – molded phenolic composition
ɀ Globe – glass, heat and impact resistant

Standard Finishes:
ɀ Natural

Size Ranges:
ɀ #16 – 3 type SO cord/cable is to be used
(not supplied)

Capacity Ranges:
ɀ 50 to 100 watt, A-21
ɀ Max. volts – 250 VAC

Certifications and
Compliances:
ɀ NEC/CEC:
Class I, Division 1 and 2, Groups C, D –
100 watts max.
Class I, Zone 1 IIB
Class II, Division 1 and 2, Group G – 75
watts max.
Class III – 75 watts max.
ɀ UL Standard: 781
ɀ CSA Standard: C22.2 No. 137

Temperature Performance
Data: (based on 40°C Ambient)
Class I, Groups C, D
Class II, Group G
Class III

T3C
Cat. #
Cord Dia.
EVH106
.375 to .625
(Model M10)

Replacement Parts
Description
Guard & globe assembly
Handle assembly (including
lampholder)
Cord connector assembly
Lampholder only

Note: See Section 2P of this catalog for suitable male plug.

916

STIBOINFO((CRH:66008com:9L:916))
CH0 0 8 L - 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Cat. #
EVH606
EVH607
EVH605
20V19-001

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0917-2 Name: 9L-917

100:
DATE: JAN 19 2006

Time: 6:01:28 PM Operator: JB

Incandescent

Application:

Standard Materials:

RCDER portable incandescent
luminaires provide general
illumination in locations having
hazardous atmospheres, such
as:
ɀ oil refineries
ɀ oil and gasoline loading docks
ɀ aircraft servicing docks and
shelters
ɀ distilleries
ɀ paint manufacturing plants
ɀ pumping stations
ɀ other Class I, Groups C and D
locations

ɀ Body – copper-free aluminum;
Lens – glass, heat and impact
resistant

ɀ Wheel base
ɀ Carrying handle
ɀ Adjustment allows rotation of
75° vertically.
ɀ Locking screws hold housing
firmly in position
ɀ Door which threads into
housing includes heat and
impact-resistant lens. Door has
notches or projections for ease
of removing or tightening
ɀ Factory sealed

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 and 2, Groups C, D
Cl. I, Zone 1 II(B) A

Portable Floodlights

Features:

COLOR: CMYK

9L

Standard Finishes:
ɀ Natural

Size Ranges:
ɀ Take cable with O.D. of .375⍯ to
.500⍯

Capacity Ranges:
ɀ RCDER-6 – 150 watt, PAR38 or
R40; 300 watt, R40 (medium
base)
ɀ RCDER-10 – 500 watt, PAR64
(Ext. Mog End Prong)

Certifications and
Compliances:
ɀ NEC/CEC:
RCDER – Class I, Division 1
and 2, Groups (C), D Class I,
Zone 1 II(B) A (see photometric
data listing)
ɀ UL Standard: 844
ɀ CSA Standard: C22.2 No. 137
(RCDER-6 only)

RCDER-6
Cat. # 44655B

RCDER-10
Cat. # 47283A

Note: CEC/CSA Certified RCDER6 - Cooper
Crouse-Hinds Canada luminaires only.

Ordering
Information:
After identifying the hazardous
area, select the model of
luminaire required for that area.
Then from the photometric data,
select appropriate Cat. No.
based on type of mounting
desired. Example: RCDER-10
No. 47283A

Temperature Performance Data (based on 40°C Ambient)
RCDER-6
RCDER-10

150W
T3B

300W
T2B

500W
T3C

US: 1-866-764-5454

STIBOINFO((CRH:66008com:9L:917))
CH0 0 8 L - 3

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

917

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0918-2 Name: 9L-918

DATE: JAN 19 2006

Time: 6:01:29 PM Operator: JB

COLOR: CMYK

TCP: 15001

Portable Mounted Lights

9L

Photometric Data
Dimensions and Weights

RCDER
Photometric Data
Beam Spread

Lamp Watts
and Type

Location

150 Watt
PAR38 Flood
150 Watt
PAR38 Spot

Class I
Groups C, D
(Zone 1 IIB)

Hor.

Vert.

Beam
Lumens

Av. Max.
Candle Power

60°

60°

1690

4000

28°

28°

1200

11500

123°

123°

3200

1950

60°

60°

3100

8900

19°

14°

3000

110000

Model

RCDER-6

300 Watt
R40 Flood
300 Watt
R40 Spot

Class I
Group D
(Zone 1 IIA)

500 Watt, PAR64
(500 PAR64/NSP)
500 Watt, PAR64
(500 PAR64/MFL)

Class I,
Group D

35°

19°

3300

37000

500 Watt, PAR64
(500 PAR64/WFL)

(Zone 1 IIA)

55°

32°

3400

13000

RCDER-10

Dimensions
RCDER-6

RCDER-10

Fixture Weights
RCDER-6
Cat. #
44655

918

STIBOINFO((CRH:66008com:9L:918))
CH0 0 8 L - 4

RCDER-10
Lbs.
(Net)
26.0

Cat. #
47283

US: 1-866-764-5454

Lbs.
(Net)
25.0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0919-2 Name: 9L-919

100:
DATE: JAN 19 2006

Time: 6:01:29 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1 & 2, Groups F, G
Cl. III
Cl. I, Zone 1 IIB
Wet Locations
Marine Locations

EVP Portable H.I.D. Floodlight

9L

Features and Benefits:
Product Features
ɀ Strong spun aluminum wheel base.

User Benefits
ɀ Provides stability, allows fixture to be hung
on a wall or lowered in an inverted position.

ɀ Sturdy hand knob.

ɀ Tightens to hold position for steady
illumination and easy aiming.

ɀ Plastic rib covered handle.

ɀ Firm, non-slip grip for transporting fixture.

ɀ Aluminum specular reflector.
ɀ Tempered, 3⁄4⍯ thick cover glass.
ɀ Nitrile rubber O-ring gasket.
ɀ Strain-relief clamps.

ɀ Directs intense beam for better visibility.
ɀ Heavy duty service.

ɀ Pre-wired, factory-sealed 100′ of 16/3 type
SOW cord supplied.

ɀ Saves on installation time and maintenance
costs.

ɀ Light weight (25 lbs.).
ɀ Fixture housing has a safety yellow finish.

ɀ Easy to handle when transporting.
ɀ Highly visible for safety precautions.

ɀ Excellent sealing for use in wet locations.
ɀ Provides extra protection against cord
damage.

Ordering Information:
Cl. I, Div. 1, Groups C, D
Cl. II, Div. 1, Group F

Applications:
The EVP portable H.I.D. floodlight† is suitable
for maintenance or emergency lighting:
ɀ in areas made hazardous by the presence
of flammable gases and vapors, combustible
dusts, or easily ignitable fibers and flyings.
ɀ in aircraft manufacturing and maintenance
facilities, shipyards, refueling depots, storage
tank cleaning, railcar manufacturing and
maintenance facilities, refineries, chemical
and petrochemical plants, textile mills, grain
elevators and pharmaceutical plants, printing
operations, wastewater and sewage
treatment plants.
ɀ in any adverse environment where portable
lighting is preferred or required.
ɀ in locations where lighting is not practical.
ɀ for task oriented lighting.

Standard Materials:
ɀ Housing – copper-free aluminum
ɀ Wheel base – spun aluminum
ɀ Handle – plastic rib covered aluminum
ɀ Reflector – aluminum
ɀ O-ring gasket – Nitrile rubber

Cat. #

70 watts HPS, 120 volts
100 watts HPS, 120 volts
150 watts HPS, 120 volts
70 watt MH, 120 volts
70 watt MH, 277 volts
70 watt MH, 347 volts
* Class II not available.

EVP4070
EVP4100
EVP4150*
EVP9070
EVP9070/277
EVP9070/347

Cl. I, Div. 1, Groups C, D
Cl. II, Div. 1, Groups F, G
Cl. III
Cat. #
100 watts HPS, 120 volts
70 watt MH, 120 volts
70 watt MH, 277 volts
70 watt MH, 347 volts

EVPG4100
EVPG9070
EVPG9070/277
EVPG9070/347

Fixtures for grain dust applications have a special limiting
device to prevent the fixture head from being positioned in
an upright position limiting dust buildup.

Temperature Performance Data:
Cat. #

Max.
Ambient °C

Class I, Division 1
T-Rating
Groups

Class II, Division 1
T-Rating
Groups

EVP4070
EVP4100
EVP4150
EVP9070
EVPG4100
EVPG9070

40
40
25
40
40
40

T4A
T4A
T3C
T4
T4A
T4

T3
T3
—
T3
T3C
T4

C, D
C, D
C, D
C, D
C, D
C, D

F
F
—
F
F, G
F, G

Certifications and
Compliances:
EVP and EVPG
ɀ NEC/CEC:
Class I, Division 1 & 2, Groups C, D
Class I, Zone 1 IIB
Class II, Division 1 and 2, Groups F, G
Class III
Wet Locations
Marine Locations
ɀ UL Standards: 781, 595, 1572
ɀ CSA Standard: C22.2 No. 137, No. 12

Electrical Ratings
High pressure sodium – (medium base)
ɀ 70, 100, & 150 watt
ɀ 120 volt 60Hz
Metal Halide – (double end)
ɀ 70 watt
ɀ 120, 277 & 347 volt; 60Hz
† EVP fixtures are not supplied with plug.
US: 1-866-764-5454

STIBOINFO((CRH:66008com:9L:919))
CH0 0 8 L - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

919

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0920-2 Name: 9L-920

9L

DATE: JAN 19 2006

Time: 6:01:30 PM Operator: JB

EVP Portable H.I.D. Floodlight

COLOR: CMYK

TCP: 15001

Photometric Data
Dimensions and Weights

Fixture Weight:
25.5 lbs.

Candelas - Thousands

Photometric Data:
EVP4070

EVP4100

EVP4150

Degrees from beam axis

Dimensions: 121⁄2⍯ D × 131⁄8⍯ W × 157⁄8⍯ H

920

STIBOINFO((CRH:66008com:9L:920))
CH0 0 8 L - 6

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0921-3 Name: 9L-921

100:
DATE: JAN 19 2006

Time: 6:01:31 PM Operator: TB

EVH Fluorescent
Handlamps & Worklights

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 and 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
Cl. I, Zone 1, IIB

9L

Application:
Portable handlamps and worklights can be used:
ɀ in areas made hazardous by the presence of flammable gases
and vapors, combustible dusts or easily ignitable fibers & flyings.
ɀ in aircraft manufacturing and maintenance facilities, shipyards,
refueling depots, storage tank cleaning, railcar manufacturing
and maintenance facilities, refineries, chemical and
petrochemical plants, textile mills, grain elevators,
pharmaceutical plants, sewage treatment plants and wastewater
treatment plants.
ɀ during plant ‘shut downs’ for maintenance and installation
requirments.
ɀ in any adverse environment where portable lighting is
preferred or required.
ɀ in locations where fixed lighting is not practical.
ɀ for task oriented lighting.
ɀ for emergency lighting applications.
ɀ when inspecting aircraft wing tanks, vats, process vessels, fuel
tanks, etc.

Features:
ɀ built in metal reflector which eliminates glare and blinding,
focusing all light on subject.
ɀ protected by patented shock absorbers to withstand rough
usage.
ɀ enclosed ballast, remote from light source for easier handling
and maneuverability.
ɀ special rubber compound bumper guards and end caps
combined with cast guard and metal rods, protecting against
damage from falling objects, bumping, or dropping.
ɀ luminaires come complete with lamp(s) and cord.
ɀ The New EVH2625E and EVH2650E incorporate an electronic
ballast in the handle for efficiency, cool operation and easy
handling.

Ambient Temperature)
Class I, Div. 1

ɀ Body and In line Ballast Unit – aluminum
ɀ Tubeshield – annealed glass
ɀ Bumper guards – rubber

Cat. No.
EVH1525
EVH1550
EVH1325
EVH1350
EVH2625
EVH2650
EVH1325 IB
EVH1350 IB
EVH2625E
EVH2650E

Standard Finishes:

Ordering Information:

Standard Materials:

ɀ Aluminum Body – White epoxy (handlamps)
ɀ Aluminum Body – Natural (worklights)
ɀ In Line Ballast Unit – Natural
ɀ Rubber bumper guards – safety yellow

Line Voltage
(60 Hz)
120
120

ɀ Supplied with 18/3 SOW cord (25 ft or 50 ft)

Electrical Ratings:

Groups
D
D
C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D

Class II, Div. 1
T-Rating
T5
T5
T5
T5
T3
T3
T5
T5
T6
T6

Groups
E, F, G
E, F, G
E, F, G
E, F, G
E, F, G
E, F, G
E, F, G
E, F, G
E, F, G
E, F, G

Watts
15
15

Cord Length
(ft)
25 ft.
50 ft.

Lamp Type Cat. No.
F15T8
EVH1525
F15T8
EVH1550

EVH Fluorescent Handlamps (With Magnetic Ballast in
Cord)

ɀ 13 to 26 Watts
ɀ Max. Volts 220VAC

Line Voltage
(60 Hz)
120
120
120
120

Certifications and Compliances:
ɀ NEC: Fluorescent Workights (15 watt units)
Class I, Div. 1 and 2, Group D
Class I, Zone 1 IIB
Class II, Div. 1, Groups E, F, G
Class II, Div. 2, Groups F, G
Class III
ɀ NEC: Fluorescent Handlamps (13 and 26 watt units)
Class I, Div. 1 and 2, Groups C, D
Class II, Div. 1, Groups E, F, G
Class II, Div. 2, Groups F, G
Class III
ɀ FM: Classification 3615
ɀ CSA: C22.2

220
220
220
220

Cord Length
(ft)
25 ft.
50 ft.
25 ft.
50 ft.

Lamp Type
F13TT
F13TT
F26DTT
F26DTT

Cat. No.
EVH1325
EVH1350
EVH2625
EVH2650

13
13
26
26

25 ft.
50 ft.
25 ft.
50ft.

F13TT
F13TT
F26DTT
F26DTT

EVH1325/220 50
EVH1350/220 50
EVH2625/220 50
EVH2650/220 50

New – EVH Fluorescent Handlamps (With Electronic
Ballast in Handle)

ɀ An isolated ballast is available on the EVH 13 Watt handlamps
for additional protection, use suffix IB.
US: 1-866-764-5454

Watts
13
13
26
26

(50 Hz)

Options:

STIBOINFO((CRH:66008com:9L:921))

T-Rating
T5
T5
T5
T5
T3
T3
T5
T5
T6
T6

EVH Fluorescent Worklights

Size Ranges:

CH0 0 8 L - 8

Temperature Performance Data: (Based on 40°C

Line Voltage
(60 Hz)
Watts
120
26
120
26

CAN: 1-800-265-0502

Cord Length
(ft)
Lamp Type
25 ft.
CF26DD/E/841
50 ft.
CF26DD/E/841

Copyright© 2006 Cooper Crouse-Hinds

Cat. No.
EVH2625E
EVH2650E

921

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0922-2 Name: 9L-922

9L

100:
DATE: JAN 19 2006

Time: 6:01:32 PM Operator: JB

EVH Fluorescent
Handlamps & Worklights

COLOR: CMYK

TCP: 15001

Dimensions

Dimensions (inches)
Work Light

Hand Lamp
(Magnetic Ballast Handlamps Only)

922

STIBOINFO((CRH:66008com:9L:922))
CH0 0 8 L - 9

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0923-4 Name: 10L-923

100:
DATE: JAN 19 2006

Time: 6:01:33 PM Operator: JB COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Exit Signs and
Emergency Luminaires
Hazardous and Non-Hazardous

10L

Description

Page No.

Exit Signs
EXL Series
EVLPF(B)-EXD
DMVF(B)-EXD

924, 925
926
927

Light-Pak TM – Emergency Lighting Systems
ELPS Series
N2LPS Series
Remote Luminaire Heads
EVLA
N2RF

928, 929
930, 931
928, 930
930

Compact Fluorescent Emergency Luminaires
CPMVFB
DMVFB
EVLPFB

932, 933
934, 935
936, 937

Table 500-3(d)
Identification Numbers.
Maximum
Temperature
Deg. C
Deg. F
450
842
300
572
280
536
260
500
230
446
215
419
200
392
180
356
165
329
160
320
135
275
120
248
100
212
85
185

US: 1-866-764-5454

STIBOINFO((CRH:66008com:10L:923))
CH0 0 0 0 9 L

CAN: 1-800-265-0502

Identification
Number
T1
T2
T2A
T2B
T2C
T2D
T3
T3A
T3B
T3C
T4
T4A
T5
T6

Copyright© 2006 Cooper Crouse-Hinds

923

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0924-2 Name: 10L-924

100:
DATE: JAN 19 2006

Time: 6:01:34 PM Operator: JB COLOR: CMYK

Factory Sealed

Application:
EXL exit signs are used:
ɀ in locations deemed hazardous due to the
presence of flammable vapors or gases, or
combustible dusts
ɀ in any building or enclosed area where
people work – where illuminated exit signs
are required
ɀ to provide distinct, highly visible exit
marking
ɀ to indicate the direction of travel to exits

Features:
ɀ Two incandescent lamps (not included)
wired in parallel – to provide extra margin of
light source reliability
ɀ Solid state circuit for extended lamp life in
AC units
ɀ Six inch red letters on white acrylic sign
panel make word ‘‘exit’’ stand out boldly and
clearly
ɀ Edge lighting characteristic of sign panel
makes visibility excellent at all lighting levels
ɀ Factory sealed explosion-proof housing
ɀ Pendant, wall and end bracket mounts
provide universal installation options
ɀ Impact-resistant acrylic sign panel needs
no guard – makes cleaning easy
ɀ Internal rectifier extends lamp life beyond
1,000-hour rated life – reduces relamping cost
ɀ Relamping tool provided

Standard Materials:
ɀ Body – copper-free aluminum
ɀ Sign panel – acrylic

Conduit Entrance:
ɀ 3⁄4⍯ hubs

Lamp Wattage:
ɀ Two 60-watt, 60T10 clear lamps for AC units
ɀ Two 25-watt, 25T10 clear lamps for DC units
ɀ Lamps not included with luminaire

Electrical Ratings:
ɀ 120VDC or 120VAC operation.

Certifications and
Compliances:
ɀ NEC: Class I, Groups C and D
Class II, Groups E, F, and G
ɀ UL Standard: 844
ɀ NFPA Life Safety Code No. 101-1991

Class I (C,D)
Class II (E,F,G)
T3C
T3C

Ordering Information:
I. When ordering an EXL Series Exit Sign, you
will need to specify:
(A) Voltage (120VAC or 120VDC)
(B) Mounting (Wall, End Bracket, or
Pendant)
(C) Exit Sign Designation
All units come standard with 3⁄4⍯ hubs and exit
signs with red lettering and white background. Complete catalog numbering is as
follows:
EXL (A) 2 (B) (C)
(A) Voltage: 120VAC . . . . . . . . . . leave blank
120VDC . . . . . . . . . . . . . . . . . . . D
(B) Mounting:

Wall . . . . . . . . . . . . . . . . . . . . . 1
End Bracket. . . . . . . . . . . . . . 2
Pendant . . . . . . . . . . . . . . . . . 3

(C) Exit Sign Designation:
A
Single Face (Wall Mount)
AA Double Face (End Bracket &
Pendant)
AB Double Face, one side arrowhead
right, the other no arrowhead
(End Bracket & Pendant)
AC Double Face, one side arrowhead
left, the other no arrowheads (End
Bracket & Pendant)
AD Double Face, one side arrowhead
both ends, the other no
arrowheads (End Bracket &
Pendant)
B
Single Face, arrowhead right
(Wall Mount)
BC Double Face, one side arrowhead
right, the other arrowhead left
(End Bracket & Pendant)
BD Double Face, one side arrowhead
both ends, the other arrowhead
right (End Bracket & Pendant)
C
Single Face, arrowhead left (Wall
Mount)
CD Double Face, one side arrowhead
both ends, the other arrowhead
left (End Bracket & Pendant)
D
Single Face, arrowhead both
ends (Wall Mount)
DD Double Face, both sides
arrowhead both ends (End
Bracket & Pendant)

Pendant Style

End Bracket Style

Wall Style

Ordering Examples Table:

Temperature Performance
Data (for both AC & DC operation):
Ambient
Temp (°C)
25
40

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 & 2, Groups C, D
Cl. I, Zone 1 IIB
Cl. II, Div. 1, Groups E, F, G

EXL Explosionproof Exit Sign

10L

TCP: 15001

Supply
Wire °C
150°C

Mounting
Type

Sign Panel
Description

Wall

Single face

End bracket
Pendant

Hub
Size

AC
Cat. #

DC
Cat. #

3⁄4

EXL21A

EXLD21A

Double face

3⁄4

EXL22AA

EXLD22AA

Double face

3⁄4

EXL23AA

EXLD23AA

Suffix Options:
Exit Signs with green lettering on white background . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GN
Unit Provided with Epoxy powder Coat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S752
277VAC – (Order ECT413 Transformer Separately)

924

STIBOINFO((CRH:66008com:10L:924))
CH0 1 0 L - 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0925-2 Name: 10L-925

100:
DATE: JAN 19 2006

Time: 6:01:35 PM Operator: JB COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

EXL Explosionproof Exit Sign

10L

Factory Sealed
Dimensions

Pendant Style

Wall Style

End Bracket Style

US: 1-866-764-5454

STIBOINFO((CRH:66008com:10L:925))
CH0 1 0 L - 2

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

925

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0926-2 Name: 10L-926

10L

100:
DATE: JAN 19 2006

Standard Materials:

EVLPF(B)-EXD exit signs are used:
ɀ in any building or enclosed area where
people work - where illuminated exit signs are
required
ɀ to provide distinct, highly visible exit
marking
ɀ to indicate the direction of travel to exits
ɀ in locations deemed hazardous due to the
presence of flammable vapours or gases, or
combustible dusts

ɀ Mounting modules, cover, ballast housing,
globe holder – copper free aluminum
ɀ Globe – heat and impact resistant glass
ɀ Exterior hardware – stainless steel

About the battery:
ɀ Bodine fluorescent battery pack ballasts are
UL Component Recognized
ɀ Sealed, maintenance-free, hightemperature nickel-cadmium
ɀ Solid state chargers are sealed inside the
ballast case
ɀ 90 minute illumination time
ɀ 10-year life expectancy
ɀ 2-year full warranty
ɀ During emergency use 1 lamp has
continuous operation
ɀ A red indicator light indicates the battery is
charging
ɀ Wiring instructions for a ⍯Push-to-Test⍯
button is supplied with the luminaire

Standard Finishes:
Copper-free aluminum – Corro-free TM
powdered epoxy

Ratings (Electrical/Size):
Sources/wattage:
ɀ 52W (2-26W lamps)
ɀ 120-277V, 50-60Hz
ɀ 120V, 60Hz
ɀ 347V, 60Hz
Conduit entries:
ɀ 3⁄4⍯, 1⍯ NPT – Pendant, Wall Bracket, Ceiling

Energy Savings
ɀ Less wattage used with compact
fluorescent lamps compared to equivalent
incandescent lamps providing the same light
output

ɀ NEC and CEC:
- Class I, Division 1, Groups B (GB
suffix), C, D
- Class I, Zone 1 Groups IIB + H2
(GB Suffix), IIB, IIA
- Class II, Class III & Simultaneous
Presence (Class I and Class II)
ɀ UL Standards
- 844 Hazardous (Classified)
Locations
- 1598 Luminaires
- 1598A Marine Locations
ɀ CSA Standards
- C22.2 No. 137

Description
Group B suitability
Factory assembled with lamps

Suffix to be added to Cat. #
GB
FA

Ordering Information:
Mounting
Type
Pendant

Wall

STIBOINFO((CRH:66008com:10L:926))

Certification &
Compliances:

Options:

Ceiling

926

Typedriver Name: TS name csm no.: 100

ɀ Marine & Wet Locations
Cl. I, Div 1, Groups B (suffix GB),
ɀ 3, 3R, 4, 4X; IP66
C, D
ɀ Cl. I, Zone 1, Groups IIB + H2
(GB suffix), IIB
ɀ Cl. II, Div 1, Groups E, F, G; Class III,
Simultaneous Presence

Application:

ɀ Six inch red letters on white glass sign
panel make the word ‘‘ EXIT’’ stand out
boldly and clearly
ɀ Light weight copper-free aluminum housing
with powdered epoxy finish
ɀ All exterior hardware is corrosion-resistant
stainless steel
ɀ Three mounting arrangements pendant,
ceiling and wall bracket
ɀ Integral ballast
ɀ High power factor (90%+) ballasts
ɀ Easier assembly, installation and
maintenance
ɀ Outdoor, hose down, marine and corrosive
environments suitable
ɀ Ideal for adverse environments typical of
industrial facilities
ɀ Ground wire for safety
ɀ Optional battery backup for operation
during power outage

TCP: 15001

ɀ

EVLPF(B) - Exit Sign
Fluorescent Luminaire

Features - Benefits:

CH0 0 6 L 1 7

Time: 6:01:36 PM Operator: JB COLOR: CMYK

US: 1-866-764-5454

Supply
Voltage
Volts/Hertz
120-277V / 50-60Hz
120V / 60Hz (Canada)
347V / 60Hz
120-277V / 50-60Hz
120V / 60Hz (Canada)
347V / 60Hz
120-277V / 50-60Hz
120V / 60Hz (Canada)
347V / 60Hz

CAN: 1-800-265-0502

Catalog Number
Fluorescent with
Battery Back-up
EVLPFA02520/UNV-EXD
EVLPFBA02520/UNV-EXD
EVLPFBA0520/120CAN-EXD
EVLPFA02520/347-EXD
EVLPFBA0520/347-EXD
EVLPFCX02520/UNV-EXD
EVLPFBCX02520/UNV-EXD
EVLPFBCX02520/120CAN-EXD
EVLPFCX02520/347-EXD
EVLPFBCX02520/347-EXD
EVLPFBX02520/UNV-EXD
EVLPFBBX02520/UNV-EXD
EVLPFBBX02520/120CAN-EXD
EVLPFBX02520/347-EXD
EVLPFBBX02520/347-EXD
Fluorescent

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0927-2 Name: 10L-927

100:
DATE: JAN 19 2006

DMVF(B) - Exit Sign
Fluorescent Luminaire

Time: 6:01:37 PM Operator: JB COLOR: CMYK

ɀ

Cl. I, Div. 2; Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II, Groups E, F, G, Cl. III
& Simultaneous Presence
ɀ Marine & Wet Locations
ɀ 3, 3R, 4X; IP66

Application:

Standard Materials:

DMVF(B) exit signs are used:
ɀ in any building or enclosed area where
people work.
ɀ where illuminated exit signs are required.
ɀ to provide distinct, highly visable exit
markings.
ɀ to indicate the direction of travel to exits.
ɀ in locations deemed hazardous due to the
presence of flammable vapors or gases, or
combustible dusts.

ɀ Ballast housings and mountings - copperfree aluminum (less than 0.4 of 1%).
ɀ Exterior hardware - stainless steel.
ɀ Globe - heat and impact resistant internally
fluted glass.

Features:

Electrical Rating Ranges:

ɀ Six inch letters on white glass sign panel
make the word ‘‘exit’’ stand out boldly and
clearly.
ɀ Housings made of die-cast copper-free
aluminum (less than 0.4 of 1% copper) for
strength and resistance to corrosion).
ɀ Mounting module equipped with integral
hub set screws for vibration resistance
(ceiling and pendant mounts).
ɀ Hubs are provided with an integral conduit
stop and bushing to help prevent damage to
field wiring during installation.
ɀEpoxy powder finish and stainless steel
external hardware for resistance to corrosion.
ɀ Long life gaskets which provide seals
between mounting module, housing, and
globe assembly.
ɀ Grounding wire for safety.
ɀ Cool operating design.
ɀ Optional emergency battery backup
operation during power outage.

ɀ 52 Watt.
ɀ 120-277V, 50-60 Hz.
ɀ 120V, 60 Hz.
ɀ 347V, 60 Hz.

About the battery:

ɀ NEC and CEC:
Class I, Division 2, Groups A, B, C, D
ɀ Class II, Class III &
Simultaneous Presence (Class I Division 2
and Class II)
Class I Zone 2
ɀ IEC:
Zone 2 Ex nR IIC
ɀ UL Standards:
844, 2279 Hazardous (Classified)
Locations.
1598 Luminaires.
1598A Marine Luminaires.
ɀ CSA Standards:
C22.2 No. 137
ɀ IEC Standards:
60079-15

ɀ Bodine fluorescent battery pack ballasts are
UL Component Recognized.
ɀ Sealed, maintenance-free, hightemperature nickle-cadmium
ɀ Solid state chargers are sealed inside the
ballast case.
ɀ 90 minute illumination time.
ɀ 10-year life expectancy.
ɀ 2-year full warranty.
ɀ During emergency use, 1 lamp has
continuous operation.
ɀ A red indicator light indicates the battery is
charging.
ɀ Wiring instructions for a ‘‘Push-to-Test’’
button is supplied with the fixture.

TCP: 15001

10L

Standard Finishes:
ɀ Aluminum - gray epoxy powder coat.
ɀ Krydon material - high reflectance white.
ɀ Stainless steel - natural.

Options:
Description
Lamps supplied with exit sign
Top hat with stainless steel threaded insert.
Restricted breathing construction.
Class I Division 2 & Zone 2 suitability.
Cooler operating temperatures (T -Numbers).
Certified for IEC Zone 2 (Suffix S826TB).
Furnished with
Terminal Block.
Crimp Terminals.
Dedicated voltage ballasts (no MT, DT or TT).

Suffix added
to Cat. No.
S714
S806
S826
S826TB

Certifications and
Compliances:

Energy Savings
ɀ Less wattage used with compact
fluorescent lamps compared to equivalent
incandescent lamps providing the same light
output.

Ordering Information:
Mounting
Type
Pendant

Ceiling

Wall

US: 1-866-764-5454

STIBOINFO((CRH:66008com:10L:927))
CH0 0 9 L - 3

Supply
Voltage
Volts/Hertz
120-277V / 50-60Hz
120V / 60Hz (Canada)
347V / 60Hz
120-277V / 50-60Hz
120V / 60Hz (Canada)
347V / 60Hz
120-277V / 50-60Hz
120V / 60Hz (Canada)
347V / 60Hz

CAN: 1-800-265-0502

Catalog Number
Fluorescent with
Battery Back-up
DMVF2A052G/UNV-EXD
DMVFB2A052G/UNV-EXD
DMVFB2A052G/120CAN-EXD
DMVF2A052G/347-EXD
DMVFB2A052G/347-EXD
DMVF2C052G/UNV-EXD
DMVFB2C052G/UNV-EXD
DMVFB2C052G/120CAN-EXD
DMVF2C052G/347-EXD
DMVFB2C052G/347-EXD
DMVF2TW052G/UNV-EXD
DMVFB2TW052G/UNV-EXD
DMVFB2TW052G/120CAN-EXD
DMVF2TW052G/347-EXD
DMVFB2TW052G/347-EXD

Fluorescent

Copyright© 2006 Cooper Crouse-Hinds

927

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0928-15 Name: 10L-928

10L

DATE: JAN 19 2006

ELPS Light-Pak TM
Emergency Lighting
System

Time: 6:01:38 PM Operator: RB

COLOR: CMYK

TCP: 15001

Cl. I, Div. 1 & 2; Groups C, D
Cl. I, Div. 1 & 2, Groups B, C, D
(With suffix GB)
Cl. II, Div. 1; Groups E, F, G
Cl. III

Typedriver Name: TS name

Cl. I, Zone 1
Simultaneous Presence
Wet Locations
NEMA 3, 3R, 12

Application:
ELPS series emergency lighting systems are
used:
ɀ to provide safe, reliable illumination indoors
or outdoors to designated areas during
failure or interruption of power to the normal
lighting system
ɀ in areas made hazardous by the presence
of flammable gases and vapors, combustible
dusts or easily ignitible fibers and flyings
ɀ in areas where corrosion, vibration,
moisture, dirt and rough usage may be
encountered
ɀ where required by the National Electrical
Code®, the Life Safety Code or other codes
ɀ in refineries, chemical and petrochemical
facilities, grain processing, handling or
storage facilities, manufacturing plants, waste
water treatment facilities and other areas
where safe, reliable, hazardous area
emergency lighting is needed

Features:
ɀ Compact factory sealed luminaire
assemblies are each furnished with a 12 watt
tungsten-halogen lamp and inner reflector for
appropriate photometrics in hazardous
areas.
ɀ Luminaire assemblies are fully adjustable
and lockable on two axes to provide flexible
and consistent light aiming capabilities.
ɀ Luminaire lens ring is threaded for easy
relamping and locks in place with hex head
set screw; will not loosen due to vibration.
ɀ Ground joint cover with external flange
design permits large opening and easy
access to internal components. Stud bolts in
diagonally opposite corners of body ease
cover removal and installation.
ɀ Neoprene cover gasket seals out moisture
for superior protection of internal
components against wetness and corrosion.
ɀ Light weight, compact size, and mounting
feet ease installation and allow placement in
confined areas.
ɀ Two 1⍯ NPT drilled and tapped conduit
openings, with plugs, are standard, for
choice of top or bottom feed.
ɀ Factory-installed PUSH-TO-TEST
pushbutton enables easy testing of system.
ɀ MAIN POWER ON pilot light indicates AC
power is being supplied to the battery
charger; pilot light jewel is threaded for easy
lamp replacement.
ɀ Stainless steel drain minimizes moisture
collection. Stainless steel breather with
aluminum cap provides ventilation, minimizes
moisture collection.
ɀ CID 101 corrosion inhibitor device is
provided with each ELPS system to help
protect electrical components and
connections.
ɀ Rugged, long-life, maintenance-free, nickel
cadmium battery provides 30 watts of power
for the required 11⁄2 hours.
ɀ Solid state battery charger for long life and
reliable service prevents deep discharge by
automatically disconnecting luminaires from
battery.

928

STIBOINFO((CRH:66008com:10L:928))
CH0 0 9 L - 3

ɀ Terminal block facilitates field wiring
connections.
ɀ Instruction sheet and maintenance record
card provided with unit in a protective plastic
envelope.
ɀ A time delay is standard; time delay is
preset at factory for 5 minute delay but can
be field set for 5 seconds or 15 minutes, thus
allowing HID type lamps time to restrike and
reach desired illumination levels.
ɀ Solid state battery charger will accept 120,
220/240 or 277 VAC, 50/60 Hz.

Electrical Ratings:
ɀ Power supply:
Input: 120, 220/240, 277 VAC, 50 or
60 hertz
0.5 Amps Maximum
Output: 12 VDC
UL listed for 28 watts for 11⁄2 hours
at 0° – 40°C
ɀ Luminaires:
Voltage: 12 VDC
Lamp Type: #789, miniature
Tungsten halogen, G4, 2-pin, 14 watt.

Certifications and
Compliances:
ɀ NEC: Class I, Groups B, C, D
Class II, Groups E, F, G
Class III
Simultaneous Presence
ɀ NEMA: 3R, 4X*, 12 (ELPS power supply)
ɀ Suitable for wet locations (EVLA fixtures)
ɀ Marine (EVLA fixtures)
ɀ UL Standard:
844 – Electric Luminaire –
Hazardous Locations
924 – Emergency Lighting and Power
Equipment
1203 – Explosionproof and DustIgnition-Proof Electrical
Equipment
ɀ Life Safety Code:
Section 5-9 (Emergency Lighting)
ɀ Suitable for Wet Locations
ɀ NEMA 3, 3R, 12
ɀ Marine

Standard Materials:
ɀ Power supply enclosure and luminaire
assembly – copper-free aluminum (less than
0.4 of 1% copper)

Standard Finishes:
ɀ Power supply enlosure and fixture
assemblies—powder coat epoxy paint finish

Ordering Information:
CATALOG NUMBER
ELPS502*

DESCRIPTION
Standard unit with
adjustable heads
ELPS-K50
Replacement power
interior, includes circuit
board and battery pack
ELPS50*
Power Supply
EVLA12*
Lamphead and arm
ELPS502-EXD
Exit sign, double sided
with EVI, red letters
ELPS502-EXD GN
Exit sign, double sided
with EVI, green letters
ELPS502-EXD GB
Exit sign, single or
double sided with Group
B EVA, red letters
ELPS502-EXD GB GN Exit sign, single or
double sided with Group
B EVA, green letters
ELPS502-EXS
Exit sign, single sided
with EVI, red letters
ELPS502-EXS GN
Exit sign, single sided
with EVI, green letters
* Base unit comes standard with Class I, Division
1, Group B.

Options:
ɀ Remote mounted EVLA12 lamp head
mounted to a Cooper Crouse-Hinds EABC36
or EABL36 1⍯ NPT outlet box
ɀ S794 key operated disconnect switch as
part of the ELPS502 emergency light system
ɀ S854 keyless operated designated
disconnect switdch as part of the ELPS502
emergency light system

* NEMA 4X pending with new ECD 4X
breather and drain

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0929-15 Name: 10L-929

DATE: JAN 19 2006

ELPS Light-Pak TM Emergency
Lighting System

Time: 6:01:39 PM Operator: RB

COLOR: CMYK

TCP: 15001

Temperature Performance Data
Photometric Data
Dimensions and Weights

Typedriver Name: TS name

csm no.: 100

10L

Photometric Data:

Temperature Performance
Data:
EVLA12—Maximum Ambient Temperature
55°C (131°C)
EVLA12 Temperature Codes (T-numbers):
ɀ Class
ɀ Class
ɀ Class
I—T4A
II*—T3B
III*—T3B
* For Class II and Class III applications, fixtures must not be
aimed more than 30° above horizontal (see diagram below).

ELPS EVI & ELPS EVA—Maximum Ambient
Temperature 40°C
ɀ Class I—T4 ɀ Class II—T3C

Dimensions

Unit Net Weights:
ɀ ELPS502 complete emergency lighting
system – 50 lbs.
ɀ ELPS50 power supply – 40 lbs.
ɀ EVLA12 luminaire assembly – 5 lbs.

Status Indication
LED Status
ɀ
ɀ
ɀɀ
ɀɀɀ
ɀɀɀɀ

US: 1-866-764-5454

STIBOINFO((CRH:66008com:10L:929))
CH0 1 0 L - 4

Condition
No light
Steady light (no blinking)
Light blinks once
Light blinks twice
Light blinks three times
Light blinks four times

CAN: 1-800-265-0502

Meaning of the Indication
AC power is removed from the circuit
Fully charged
Charging
Battery failure
Circuit failure
Lamp failure

Copyright© 2006 Cooper Crouse-Hinds

929

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0930-3 Name: 10L-930

10L

100:
DATE: JAN 19 2006

Time: 6:02:44 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 2, Groups B, C, D
Class I, Zone 2
Wet Locations
NEMA 3, 3R

LIGHT-PAK TM N2LPS Emergency
Lighting System

Application:
Light-Pak N2LPS emergency lighting
systems are used:
ɀ to provide reliable illumination for egress
areas during failure or interruption of power
to the normal lighting system
ɀ in areas where flammable gases or vapors
may become present due to abnormal,
unusual, or accidental conditions
ɀ in manufacturing plants, refineries,
petrochemical and chemical plants, waste and
sewage treatment facilities, oil terminals, food
processing facilities, breweries, and other
industrial manufacturing or process industry
facilities subject to wet or corrosive conditions
ɀ to illuminate machinery or panels during a
loss of AC power
ɀ where moisture, dirt, dust, or corrosion will
limit the life and reliability of ordinary
emergency lighting systems
ɀ where required by the National Electrical
Code®, the Life Safety Code® or other
applicable codes
ɀ Outdoor applications

Features:
ɀ Compact factory assembled system with
two 8 watt sealed beam halogen lamps.
ɀ Nonmetallic, enclosed and gasketed
construction; a CID101 corrosion inhibitor
device is also included.
ɀ Solid state battery charger will accept 120,
220, and 277 VAC, 50/60 Hz.
ɀ A time delay is standard; time delay is
preset at factory for 5 minute delay but can
be field set for 5 seconds or 15 minutes, thus
allowing HID type lamps time to restrike and
reach desired illumination levels.
ɀ ‘‘Push-to-Test’’ button and ‘‘Main Power
On’’ pilot light are conveniently located on
side of system.
ɀ Sealed, lead calcium battery(ies); one
battery supplies 28 watts of power (two
batteries 56 watts) for 11⁄2 hrs.
ɀ Luminaire heads constructed of rugged
Noryl® thermoplastic material with nylon and
plastic coated hardware.
ɀ Cover has six captive stainless steel screws;
factory installed 3⁄4⍯ conduit hub opening is
standard, located on top of system.
ɀ Remote luminaire head assemblies (one or
two) are available for mounting of luminaire
heads away from main power supply system.

Temperature Performance
Data: (based on 40°C ambient)
Cat. #
Class I, Division 2
N2LPS (all)
T4A
N2RF (all)
T5
(NOTE: Ambient temperature at which the
Light-Pak system is rated is 0°C (32°F) to
40°C (104°F). Lower ambient temperatures
will reduce battery capacity.)
National Electrical Code and Life Safety Code are
registered trademarks of the National Fire Protection
Association, Inc.
Noryl is a registered trademark of General Electric
Company.

930

STIBOINFO((CRH:66008com:10L:930))
CH0 1 0 L - 5

Standard Materials:

Ordering Information:

ɀ Power supply and remote luminaire
enclosures – Krydon® fiberglass-reinforced
polyester
ɀ Luminaire heads – Noryl® thermoplastic
ɀ Exterior hardware – Nylon, plastic coated,
and stainless steel
ɀ Cover gasket – Hypalon® synthetic rubber

Description
Cat. #
28 watt, 6 volt output power
supply with two 8 watt
tungsten halogen luminaires . . N2LPS6222
56 watt, 6 volt output power
supply with two 8 watt
tungsten halogen luminaires . . N2LPS6422
28 watt, 6 volt output power
supply only (less luminaire
heads) . . . . . . . . . . . . . . . . . . . . . N2LPS6220
56 watt, 6 volt output power
supply only (less luminaire
heads) . . . . . . . . . . . . . . . . . . . . . N2LPS6420
Remote luminaire assembly
with one 8 watt luminaire head N2RF621
Remote luminaire assembly
with two 8 watt luminaire
heads . . . . . . . . . . . . . . . . . . . . . N2RF622
Remote luminaire assembly
with one 12 watt 6 volt lamp
for mounting in Class 1,
Division 1, Group C
and D areas . . . . . . . . . . . . . . . . EVLA126
Power supply with two 8 watt
tungsten halogen luminaires
and single face exit sign.
Exit sign operates in
emergency mode only.. . . . . N2LPS6422-EXS
Power supply with two 8 watt
tungsten halogen luminaires
and double face exit sign. Exit
sign operates in emergency mode only.
. . . . . . . . . . . . . . . . . . . . . . . . . N2LRS6422-EXD

Electrical Ratings:
ɀ Power supply –
Input: 120, 220, or 277 VAC, 50 or 60 Hz;
25 watts max.
Output: 6 VDC;
N2LPS6222, N2CPS6220 – 28 watts for
11⁄2 Hrs.
N2LPS6422, N2LPS6420 – 56 watts for
11⁄2 Hrs.
ɀ Luminaires – Voltage: 6 VDC; Lamp type:
8 watt, tungsten halogen PAR36 sealed beam
(General Electric #H7551)

Certifications and
Compliances:
ɀ NEC – Class I, Division 2,
Groups B,C,D
ɀ UL Standards: 924 (Emergency Lighting
and Power Equipment); 844 (Electric
Luminaires Hazardous Locations)
ɀ Life Safety Code NFPA101® – Section 5-9
(Emergency Lighting)
ɀ Wet Locations Suitability

Unit Net Weights:
ɀ N2LPS6222 – 16 lbs.
ɀ N2LPS6422 – 21 lbs.
ɀ N2LPS6220 – 12 lbs.
ɀ N2LPS6420 – 17 lbs.
ɀ N2RF621 – 6 lbs.
ɀ N2RF622 – 8 lbs.

US: 1-866-764-5454

CAN: 1-800-265-0502

Option:
Suffix to be
Added to
Cat. #

Description
N2LPS6422 with exit sign EXS
or EXD that operates in both
normal and emergency mode.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S840
Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0931-2 Name: 10L-931

100:
DATE: JAN 19 2006

Time: 6:02:45 PM Operator: JB COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Photometric Data
Dimensions and Weights

LIGHT-PAK TM N2LPS Emergency
Lighting System

10L

Photometric Data:
Isofootcandle Chart
Horizontal Distribution

Vertical Distribution

Wire Sizing for Remote Installation:
For Copper Wire –
Running Distance* (ft.) Between Power Supply and Remote Luminaire
Load In Watts
Wire Size
8
16
24
16 AWG
26
13
6
14 AWG
42
21
10
12 AWG
66
33
16
* Maximum distance to limit line voltage drop to 5%.

32
3
5
8

Wire Size
10 AWG
8 AWG
6 AWG

Dimensions (N2LPS):

8
106
168
270

Load In Watts
16
24
53
26
84
42
135
67

32
13
21
33

Weights:
Description

Weight

N2LPS6222 (28 watt system). . . . . . . . . 16 lbs.
N2LPS6422 (56 watt system). . . . . . . . . 21 lbs.

Weights:
Description
Weight
N2RF621 (8 watt) . . . . . . . . . . . . . . . . . . . . 6 lbs.
N2RF622 (16 watt) . . . . . . . . . . . . . . . . . . . 8 lbs.

Dimension:
Dimensions – Remote Luminaires (N2RF621 – N2RF622)

US: 1-866-764-5454

STIBOINFO((CRH:66008com:10L:931))
CH0 1 0 L - 6

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

931

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0932-8 Name: 10L-932

10L

100:
DATE: JAN 19 2006

Time: 6:02:47 PM Operator: RB

CPMVFB Emergency
Compact Fluorescent
Continuous Operation
Champ-Pak TM Luminaires

Application:

ɀ where emergency lighting is required to
permit workers in industrial areas to safely
encounter their surroundings during power
failures
ɀ where emergency egress lighting is
required, such as: catwalks, walkways,
tunnels, doorways, stairs, stairwells, ramps
and aisles
ɀ indoor and outdoor wall mounting or
vertical surface mounting where minimal
luminaire depth is required in:
- Manufacturing plants and heavy industrial
facilities
- Industrial process facilities such as
refineries, chemical, petrochemical,
pharmaceutical and platforms
- Waste or sewage treatments plants
- Offshore, dockside and harbor
installations
ɀ For security and safety lighting in industrial
facilites for lighting of loading docks, tunnels
and stairways
ɀ For marine, wet location, hosedown and
corrosive environments

Features & Benefits:

ɀ Unique compact shallow-profile design
mounts virtually anywhere
ɀ Side hinged cover with two screw closing
for easy installation and maintenance
ɀ Gray Corro-free TM epoxy powder coat
two-piece housing provides superior
corrosion resistance
ɀ Unique stainless steel wire guard accessory
attaches without any additional hardware for
easy installation and maintenance
ɀ Glass refractor provides uniform light
distribution to eliminate glare
ɀ Silicon gaskets make luminaire suitable for
NEMA 4X, Marine enviroments
ɀ High power factor ballasts (+90%) are
standard, which allow more luminaires per
circuit

COLOR: CMYK

TCP: 15001

ɀ

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div 2 & Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G,
Cl. III & Simultaneous
Presence *
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66
ɀ Emergency Lighting

Certifications and
Compliances:
ɀ NEC and CEC:
Class I, Division 2, Groups A, B, C, D
Class II, Class III & Simultaneous
Presence (Class I Division 2 and
Class II)
Class I Zone 2
ɀ IEC:
Zone 2 Ex nR IIC
ɀ UL Standards
844, 2279 Hazardous (Classified)
Locations
1598 Luminaires
1598A Marine Locations
ɀ CSA Standards
C22.2 No. 137
ɀ IEC Standards
60079-15

About the battery:
ɀ Bodine fluorescent battery pack ballasts are UL Component Recognized
ɀ Sealed, maintenance-free, high-temperature nickel-cadmium
ɀ Solid state chargers are sealed inside the ballast case
ɀ 90 minute illumination time
ɀ 10-year life expectancy
ɀ 2-year full warranty
ɀ During auxiliary use 1 lamp has continuous operation
ɀ A red indicator light indicates the battery is charging
ɀ Wiring instructions for a ‘‘Push-to-Test’’ button is supplied with the fixture

Electrical Rating Ranges:
ɀ 52 watts
ɀ 120-277V, 50-60Hz
ɀ 120V, 60Hz
ɀ 347V, 60Hz

Standard Materials:

Options:

Standard Finishes:

Restricted Breathing Construction
Class I Division 2 & Zone 2 Suitability
Cooler Operating Temperatures (T-numbers)
Certified for IEC Zone 2 (Suffix S826TB)
S826TB
Furnished with
Terminal Block
Crimp Terminals
Dedicated voltage ballasts (no MT, DT or TT)
Factory Assembled with Lamp installed
FA
Fused - projects ballast and capacitors against
S658†
abnormal line conditions
(Not for use in Canada)
(Not for Marine use)

ɀ Luminaire housing and door frame
assembly - copper-free aluminum
ɀ External hardware - stainless steel
ɀ Lens - heat and impact-resistant refractor
style glass
ɀ Gaskets - silicon rubber
ɀ Reflector - aluminum light sheet
ɀ Wire guard - stainless steel
ɀ Aluminum - Corro-free TM epoxy powder coat
ɀ Stainless steel - natural
* Consult Cooper Crouse-Hinds

Suffix to be added
to Cat. #
S826

Accessories:
Stainless Steel Wire Guard
† When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

932

STIBOINFO((CRH:66008com:10L:932))
CH0 0 9 L - 3

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Cat. #
P55

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0933-6 Name: 10L-933

DATE: JAN 19 2006

Time: 6:02:48 PM Operator: JB COLOR: CMYK

CPMVFB Emergency
Compact Fluorescent

TCP: 15001

Ordering Information
Dimensifons & Weights

Typedriver Name: TS name csm no.: 100

10L

Continuous Operation
Champ-Pak TM Luminaires
Ordering Information:
Lamp
Hub Size Watts

Catalog Number for
use with ANSI Lamps

3⁄4NPT

CPMVFB2W026

26

Standard Voltage Ballasts
NEC/UL
CEC/CSA (cUL)
Voltage 120-277V 50-60Hz
120V/60Hz
347V 60Hz
Suffix
/UNV
/120CAN
/347

Dimensions (Inches):

Net Weight:
Luminaire Less Guard
P55 Guard

18.6 Lbs.
0.5 Lbs.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:10L:933))
CH0 1 0 L - 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

933

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0934-4 Name: 10L-934

10L

100:
DATE: JAN 19 2006

DMVFB Emergency
Compact Fluorescent
Continuous Operation
Champ® Luminaires

Time: 6:02:49 PM Operator: RB

COLOR: CMYK

ɀ

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

Application:

Energy Savings

DMVF series Champ lighting luminaires are
used:
ɀ where emergency lighting is required to
permit workers in industrial areas to safely
encounter their surroundings during power
failures.
ɀ Where emergency egress lighting is
required, such as: catwalks, walkways,
tunnels, doorways, stairs, stairwells, ramps,
and aisles.
ɀ in areas made hazardous by abnormal
conditions resulting in the presence of
flammable vapors or gases.
ɀ in areas made hazardous by the presence
of combustible dusts.
ɀ where combustible dusts and flammable
vapors are present simultaneously.
ɀ in marine applications where water spray
and corrosive atmospheres are
considerations.
ɀ on installations where vibration and rough
usage are problems.
ɀ where a cool, efficient light source is
required.
ɀ in areas that require lamps to reach full
illumination immediately.
ɀ in refineries, chemical and petrochemical
facilities, grain processing, handling or
storage facilities, manufacturing plants waste
water treatment plants sewage treatment
plants, oil terminals, food processing
facilities, breweries, and any other
manufacturing or processing facility where
safe, reliable, hazardous area fluorescent or
auxiliary lighting is needed.

ɀ Less wattage used with compact
fluorescent lamps compared to equivalent
incandescent lamps providing the same light
output.

Standard Features:
ɀ Housings made of die-cast copper-free
aluminum (less than 0.4 of 1% copper) for
strength and resistance to corrosion.
ɀ Mounting modules equipped with integral
hub set screws for vibration resistance
(ceiling, pendant, and quad mounts).
ɀ Hubs are provided with an integral conduit
stop and bushing to help prevent damage to
field wiring during installation.
ɀ Epoxy powder finish and stainless steel
external hardware for resistance to corrosion.
ɀ Long-life gaskets which provide seals
between mounting module, housing, and
optical assembly.
ɀ Grounding wire for safety.
ɀ Cool operating design.
ɀ Optional stainless steel open bottom guard
permits direct access to the globe for easy
relamping.
ɀ Battery pack ballast for emergency lighting.

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl.III
& Simultaneous Presence
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66
ɀ Emergency Lighting

About the battery: (DMVFB
Units)
ɀ Bodine fluorescent battery pack ballasts are
UL Component Recognized.
ɀ Sealed, maintenance-free, hightemperature nickel-cadmium
ɀ Solid state chargers are sealed inside the
ballast case.
ɀ 90 minute illumination time
ɀ 10-year life expectancy
ɀ 2-year full warranty
ɀ During auxiliary use 1 lamp has continuous
operation
ɀ A red indicator light indicates the battery is
charging.
ɀ Wiring instructions for a ‘‘Push-to-Test’’
button is supplied with the luminaire.

Standard Materials:
ɀ Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%).
ɀ Exterior hardware and guards – stainless
steel.
ɀ Reflectors – Krydon® fiberglass-reinforced
polyester material.
ɀ Globe – heat and impact resistant internally
fluted glass.

Standard Finishes:
ɀ Aluminum – gray epoxy powder coat.
ɀ Krydon material – high reflectance white.
ɀ Stainless steel – natural.

Electrical Rating Ranges:
ɀ 52 and 64 watts
ɀ 120-277V, 50-60 Hz
ɀ 347V, 60 Hz

Certifications and
Compliances:
ɀ NEC/CEC:
Class I, Division 2, Groups A, B, C, D
Class II, Class III &
Simultaneous Presence (Class I
Division 2 and Class II)
Class I Zone 2
Emergency Lighting
ɀ IEC
Zone 2 Ex nR IIC
ɀ UL Standards
844, 2279 Hazardous (Classified)
Locations
1598 Luminaires
1598A Marine Locations
924 Emergency Lighting
ɀ CSA Standards
C22.2 No. 137
ɀ IEC Standards
60079-15

Options:
Suffix to be
Description
added to Cat. No.
ɀ Restricted Breathing
Construction
S826
- Class I Division 2 &
Zone 2 Suitability
- Cooler Operating
Temperatures
(T-Numbers)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
S826TB
- Furnished with
Terminal Block
Crimp Terminals
ɀ Emergency
Operation only
Consult
Crouse- Hinds
ɀ Factory Assembled with lamps installed for
additional labor savings . . . . . . . add suffix FA.
ɀ Fused – to protect ballast against abnormal
line conditions (not for use in Canada)
(not for Marine use) . . . . . . . add suffix S658.*
ɀ Lamps supplied with luminaire . . . add suffix
S714.
ɀ Top hat with stainless steel threaded insert
to attach ballast housing . . . . add suffix S806.
ɀ TEFLON® coating on globe for increased
shatter protection . . . . . . . . . . add suffix S808.

Accessories:
(Order separately)
ɀ Dome Cat. # RD739
ɀ 30° Angle Cat. # RA739
* When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

934

STIBOINFO((CRH:66008com:10L:934))
CH0 1 0 L - 7

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0935-3 Name: 10L-935

DATE: JAN 19 2006

DMVFB Emergency
Compact Fluorescent
Continuous Operation
Champ® Series Luminaires

Time: 6:02:50 PM Operator: RB

ɀ

Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I,
Div 2 & Zone 2 (Suffix S826)
ɀ Certified for IEC Zone 2
(Suffix S826TB)
ɀ

Mounting
Style
Pendant Mount

Lamp
Watts
52

Flexible Pendant
Mount

3⁄4
3⁄4

52
64

DMVFB2HA052GP
DMVFB2HA064GP

Ceiling Mount ThruFeed

3⁄4

52

1
3⁄4
1

64

DMVFB2C052GP
DMVFB3C052GP
DMVFB2C064GP
DMVFB3C064GP

3⁄4

52

1
3⁄4
1

64

Wall Mount
Thru-Feed

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

Cl. II Groups E, F, G, Cl. III &
Simultaneous Presence
ɀ Marine & Wet Locations
ɀ 3, 3R, 4, 4X; IP66
ɀ Emergency Lighting

10L

DMVFB Series
Fluorescent with Battery
Back-Up with G303 Globe
and P33 Guard
Cat. No.
DMVFB2A052GP
DMVFB3A052GP
DMVFB2A064GP
DMVFB3A064GP

Hub
Size
3⁄4
1
3⁄4
1

64

COLOR: CMYK

DMVFB2TW052GP
DMVFB3TW052GP
DMVFB2TW064GP
DMVFB3TW064GP

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
12-1/2° Angle

3⁄4
3⁄4

52
64

DMVFB25Q052GP
DMVFB25Q064GP

Stanchion Mount
25° Angle

1-1⁄2
1-1⁄2

52
64

DMVFBJ052GP
DMVFBJ064GP

Stanchion Mount
Straight

1-1⁄2
1-1⁄2

52
64

DMVFBP052GP
DMVFBP064GP

Note: For technical information on
family trees, temperature
performance data, dimensions,
weights, and photometrics, refer
to DMVF Series in Section 6L.

NOTES:
1. Catalog numbers are basic numbers. Voltage must be specified.
Standard Voltage Ballasts
NEC/UL
Voltage
Suffix

US: 1-866-764-5454

STIBOINFO((CRH:66008com:10L:935))
CH0 1 0 L - 8

120-277V 50-60Hz
/UNV

CAN: 1-800-265-0502

CEC/CSA (cUL)
120V/60Hz
/120CAN

Copyright© 2006 Cooper Crouse-Hinds

347V 60Hz
/347

935

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0936-4 Name: 10L-936

10L

100:
DATE: JAN 19 2006

Time: 6:02:51 PM Operator: JB COLOR: CMYK

EVLPFB Emergency
Compact Fluorescent
Continuous Operation
Low Profile Luminaires

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ

ɀ Marine & Wet Locations
Cl. I, Div. 1, Groups B
ɀ 3, 3R, 4, 4X; IP66
(GB Suffix), C, D
ɀ Cl. I, Zone 1, Groups
ɀ Emergency Lighting
IIB + H2 (GB suffix), IIB, IIA
ɀ Cl. II, Div. 1, Groups E, F, G;
Class III, Simultaneous Presence

Application:
Cooper Crouse-Hinds Low Profile
Hazard ȿ Gard® luminaires are used in:
ɀ areas that require lamps to reach full
lumination immediately.
ɀ where emergency lighting is required to
permit workers in industrial areas to safely
encounter their surroundings during power
failures.
ɀ where emergency lighting is required such
as: catwalks, walkways, tunnels, doorways,
stairs, stairwells, ramps and aisles.
ɀ areas where flammable or explosive vapors
or gases are present
ɀ hazardous areas, both indoors and
outdoors, where long life and low
maintenance costs are desired
ɀ petroleum refineries, chemical,
petrochemical and pharmaceutical plants, oil
terminals, gas plants and other heavy
process industry facilities
ɀ waste treatment facilities
ɀ drilling platforms and other coastal and
offshore hazardous areas

ɀ Mounting modules, cover, ballast housing,
globe holder – copper free aluminum
ɀ Globe – heat and impact resistant glass
ɀ Exterior hardware – stainless steel
ɀ Reflectors (dome & angle) – Krydon TM
fiberglass-reinforced polyester

Standard Finishes:
Copper-free aluminum – Corro-free TM
powdered epoxy
ɀ Krydon – white
ɀ Stainless steel guard

Features - Benefits:

Ratings (Electrical/Size):

ɀ Small compact size
ɀ Two start Acme threaded construction
ɀ Easier assembly, installation and
maintenance
ɀ Light weight copper-free aluminum housing
with powdered epoxy finish
ɀ All exterior hardware is corrosion-resistant
stainless steel
ɀ Four mounting arrangements pendant,
ceiling, wall bracket and stanchion
ɀ Integral ballast
ɀ High power factor (90%+) ballasts
ɀ Uses same mounting modules as the
standard Hazard ȿ Gard®
ɀ Internally fluted glass globes
ɀ Krydon® construction dome and angle
reflectors – won’t rust, corrode, dent, chip or
peel
ɀ Now available in components – luminaire
body, mounting module, guard, reflectors
ɀ Three wire construction
ɀ For energy conservation, luminaires can be
switched off without affecting the emergency
operation feature

Sources/wattage:
ɀ Fluorescent continuous operation
Emergency Lighting 52W (2-26W lamps) and
64W (2-32W lamps) Compact fluorescent
Voltages:
ɀ Fluorescent Emergency Lighting
– 120-277V, 50-60 Hz
– 120V, 60 Hz
– 347V 60Hz
Conduit entries:
ɀ 3⁄4⍯, 1⍯ NPT – pendant, wall bracket, ceiling
ɀ 11⁄4⍯ NPT – stanchion

Standard Materials:

Description
Dome reflector
Angle reflector

ɀ Mounting modules, cover, ballast housing,
globe holder – copper free aluminum
ɀ Globe – heat and impact resistant glass
ɀ Exterior hardware – stainless steel
ɀ Reflectors (dome & angle) – Krydon TM
fiberglass-reinforced polyester

Energy Saving:
ɀ Less wattage used with compact
fluorescent lamps compared to equivalet
incandecent lamps providing the same light
output.

936

STIBOINFO((CRH:66008com:10L:936))
CH0 1 0 L 2 0

Standard Materials:

Certification &
Compliances:
ɀ NEC and CEC:
Class I, Division 1, Groups B (with GB
suffix), C, D
Class I, Zone 1 Groups IIB + H2 (GB
Suffix), IIB, IIA
Class II, Class III & Simultaneous Presence
(Class I and ClassII)
Emergency Lighting
ɀ UL Standards
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
924 Emergency Lighting
ɀ CSA Standards
C22.2 No. 137

Options:
Description
Group B suitability
Fused (not for use in Canada)
(not for Marine use)
Factory assembled with lamps
Emergency Operation only

Suffix to be added to Cat. #
GB
S658*
FA
Consult Cooper
Crouse-Hinds

Accessories:
Cat. #
RD739
RA739

About the Battery

ɀ Bodine fluorescent battery pack ballasts are
UL Component Recognized.
ɀ Sealed, maintenance-free, hightemperature nickle-cadmium.
ɀ Solid state chargers are sealed inside the
ballast case.
90 minute illumination time.
10-year life expectancy
ɀ 2-year warranty.
ɀ During emergency use, 1 lamp has
continuous operation.
ɀ A red indicator light indicates the battery is
charging.
ɀ Wiring instructions for a ‘‘Push-to-Test’’
button is supplied with the fixture.

US: 1-866-764-5454

CAN: 1-800-265-0502

* When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0937-2 Name: 10L-937

100:
DATE: JAN 19 2006

EVLPFB Emergency
Compact Fluorescent
Continuous Operation
Low Profile Luminaires

Time: 6:02:52 PM Operator: JB COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

ɀ Marine & Wet Locations
Cl. I, Div. Groups B
ɀ 3, 3R, 4, 4X; IP66
(GB suffix), C, D
ɀ Emergency Lighting
ɀ Cl. I, Zone 1, Groups IIB +
H2 (with Suffix GB), IIB, IIA
ɀ Cl. II, Div 1, Groups E, F, G;
Class III, Simultaneous Presence
ɀ

10L

Ordering Information
Luminaire Body
Less Mounting
Module & Guard

Pendant
Wall Bracket† Ceiling†
Stanchion
Hub With Guard
With Guard
With Guard
With Guard
Catalog #
Catalog #
Catalog #
Catalog #
Watt Size Catalog #
Fluorescent with Emergency Ballast – High Power Factor Ballast (Min. P.F. 90%)
EVLPFBA02521 EVLPFBBX02521 EVLPFBCX02521
EVLPFB0520
52W 3⁄4
1
EVLPFBA03521 EVLPFBBX03521 EVLPFBCX03521
EVLPFBJ04521
11⁄4
64W 3⁄4
EVLPFBA02641 EVLPFBBX02641 EVLPFBCX02641
EVLPFB0640
1
EVLPFBA03641 EVLPFBBX03641 EVLPFBCX03641
EVLPFBJ04641
11⁄4

Pendant Mount

Complete Catalog Numbers as follows:
1.

Standard Voltage Ballasts
NEC/UL
Voltage
Suffix

120-277V 50-60Hz
/UNV

CEC/CSA (cUL)
120V/60Hz
/120CAN

347V 60Hz
/347

Example: EVLPFB02521/UNV
2. Other Voltages - Consult Cooper Crouse-Hinds

†Wall Bracket Mount

Note: For technical information on
family trees, temperature
performance data, dimensions,
weights, and photometrics, refer
to DMVF Series in Section 5L.
EVFPFB Fluorescent Emergency Lighting
ɀ Three wire construction, for switching purposes, is standard on Fluorescent Emergency
Lighting.
ɀ For energy conservation, luminaires can be switched off without affecting the emergency
operation feature.

†Ceiling Mount

* Test Switch is remote mounted.
Use Cooper Crouse-Hinds EDSC218 (Not furnished).

Stanchion Mount
†Ceiling and bracket mounts have 4 hubs: 3 are plugged.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:10L:937))
CH1 0 L - 2 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

937

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0938-1 Name: Note Page-938

DATE: JAN 19 2006

Time: 6:02:53 PM Operator: JB

COLOR: CMYK

Notes Page

938

STIBOINFO((CRH:66008com::938))
CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0939-6 Name: 11L-939

100:
DATE: JAN 19 2006

Time: 6:02:54 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

2

Visual Signaling Devices
‘‘Steady On’’ Beacons, ‘‘Rotating’’ Beacons and ‘‘Flashing’’ Strobe Lights

11L

Luminaires for Hazardous and
Non-Hazardous Locations
Description

Application

940

VF Beacons Fluorescent ‘‘Steady On’’

941

EX Fire Alarm Strobe Light

942, 944, 949

EX Strobe Light

943, 944, 949

EX Steady-on Beacon

945, 946, 949

EX Rotating Beacon

947, 948, 949

VDAS Strobe Lights

950

US: 1-866-764-5454

STIBOINFO((CRH:66008com:11L:939))

CH0 0 0 0 8 L

Page No.

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

939

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0940-9 Name: 11L-940

DATE: JAN 19 2006

Time: 6:02:55 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Visual Signaling Devices
‘‘Steady On’’ Beacons, ‘‘Rotating’’ Beacons and ‘‘Flashing’’ Strobe Lights

11L

Luminaires for Hazardous and
Non-Hazardous Locations
Application:

Considerations for
Selection:

ɀ for use in hazardous and non-hazardous
areas (as shown in the quick selector chart
shown below).
ɀ to supplement audible signals, especially in
high noise areas.
ɀ as visual signals or warning lights.
ɀ to identify the location of safety equipment
such as emergency shower, eye wash
stations, and emergency telephones, fire
extinguishers and emergency stop switches.
ɀ for status indication of machinery or
processes.
ɀ to indicate dangerous areas or areas
requiring caution.
ɀ to signal dangerous or hazardous
conditions.

Environmental:
ɀ What is the hazardous area classification
(NEC/CEC) of the location in which the
luminaire will be installed?
Signaling Requirements:
ɀ What will the visual signal be used for
(Communicating, alerting, warning)?
Physical Arrangements:
ɀ Type of luminaire mounting needed.

Quick Selector Chart:
Series
VF - ‘‘Steady On’’
Beacons
EX Strobes,
Steady-On Beacons,
& Rotating Beacons
VDAS Strobes

Hazardous Area
Suitability
CL. I, Div 2, Groups A, B, C, D
CL. I, Zone 2, Group IIC
Wet Locations - 3, 3R
Cl. I, Div. I, Groups C,D
Cl. I, Zone 1 & 2, Group IIB
Cl. II, Div. I, Groups E,F,G
Wet Locations - 4X, Marine
CL. I, Div 2, Groups A, B, C, D
CL. I, Zone 2, Group IIC
CL. II, Div 2, Groups F, G; Cl. III
Wet Locations - 3, 3R, 4, 4X

Warning and Visual Indication
Colors Available
Green
Blue
Red
Yellow
Clear

940

STIBOINFO((CRH:66008com:11L:940))
CH0 0 1 1 - 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Lamp
Watts
(2) 9W

Xenon
Strobe
Halogen
Beacon
Xenon
Strobe

Volts
120V 60 Hz.

120 VAC
24 VDC
12-48 VDC
24-28 VDC
120V 60 Hz
240V 60 Hz
12-24VDC

Typical Uses
Emergency Shower or Eye Wash Station
Emergency Telephones
Danger, Equipment Operating
Caution
Equipment end of cycle

Copyright© 2006 Cooper Crouse-Hinds

No. of
Lamps
2

1

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0941-3 Name: 11L-941

DATE: JAN 19 2006

VF ‘‘Steady On’’ Beacon
Compact Fluorescent
Warning and Visual
Indication Light

Time: 6:02:55 PM Operator: JB COLOR: CMYK

ɀ

ɀ

ɀ

ɀ

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, Groups IIC
ɀ Wet Locations
ɀ 3, 3R

TCP: 15001

Typedriver Name: TS name csm no.: 100

Green - Safety Shower
Blue - Emergency
Telephones
ɀ Red - Danger
ɀ Amber - Warning
ɀ Visual Signal

Application:

Options:

VF series ‘‘Steady On’’ fluorescent beacons
are used indoors or outdoors:
ɀ where the energy efficiency and long life of
compact fluorescent lamps are desired
ɀ for continuous signaling requirements.
ɀ where a continuous ‘‘Steady-On’’
fluorescent light signal is required
ɀ where ambient noise makes audible signals
difficult to hear.
ɀ as visual signals or warning lights on
loading docks; at obstructions, exits or
entrances.
ɀ for identifying the location of safety
equipment such as safety showers or
emergency telephones.
ɀ for call signals.
ɀ for status indication or area lighting on
offshore rigs, mines, refineries etc.
ɀ in locations which are hazardous due to the
presence of flammable vapors or gases and
where dampness or corrosion are present.
ɀ to identify a potentially dangerous obstacle.
ɀ as a continuous source to warn or
communicate.
Typical Applications are:
ɀ Green - Identify safety shower locations
ɀ Blue - Identify emergency telephones
ɀ Amber - Caution signal
ɀ Red - Danger signal
ɀ Red & Amber - Emergency situations
ɀ Blue & Red - Security or malfunctioning
equipment.
ɀ Green & Clear - Equipment end of cycle.

Description

Features:
ɀ Extremely energy efficient, only 18 watt
(2-9 watt compact fluorescent lamps)
ɀ Packs considerable punch for ample
visibility even in harsh enviroments.
ɀ Compact size and light weight allow
adaptation and easy installation in many
industrial applications
ɀ Cast copper-free aluminum (less than 0.4 of
1% copper) construction and epoxy powder
finish provide excellent resistance to
corrosion
ɀ Variety of mounting arrangements to suit
any lighting layout – pendant, ceiling, wall
bracket, angle stanchion.
ɀ Glass globes are internally fluted and
stippled to enhance visibility. Exteriors are
smooth to shed dust
ɀ Grounding wire for safety

ɀ 250 volt Nameplate
for export applications

Weights:

11L

Suffix added to
Cat. No.
/250
2-Lamp
Luminaire
With Globe &
Guard (lbs.)
5
51⁄4
71⁄2

Luminaire
Type
VFA
VFHF
VFHBF

Temperature Performance
Data:
Style
1 & 2 Class I
Lamp Div. 2
9W
T3B

Max.
Ambient
40°C

Supply
Wire °C
75°C

Minimum
Operating
–4°C (25°F)

Certifications and
Compliances:
NEC and CEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 2
ɀ UL Standards
844
1598 Luminaires
ɀ CSA standards
c22.2 No. 137

Dimensions
Pendant

Wall

VFA

Stanchion

VFHBF

VFHA

Ceiling

Standard Materials:
ɀ Bodies and guards – copper-free aluminum
(less than 0.4 of 1%)
ɀ Globes – glass

Standard Finishes:

VFHF

ɀ Copper-free aluminum – powder epoxy
finish

Electrical Ratings:
ɀ Input voltage – 120 VAC, 60 hertz
ɀ Wattages: 18W (Two 9W lamps)

Ordering Information:
Style
Pendant
Wall
Ceiling
Stanchion

US: 1-866-764-5454

STIBOINFO((CRH:66008com:11L:941))
CH0 1 0 L - 1

Red

Catalog Number - by Globe Color
Amber
Green
Blue

Clear

VFA222GRP
VFHBF222GRP
VFHF222GRP
VFHA422GRP

VFA222GAP
VFHBF222GAP
VFHF222GAP
VFHA422GAP

VFA222GP
VFHBF222GP
VFHF222GP
VFHA422GP

CAN: 1-800-265-0502

VFA222GGP
VFHBF222GGP
VFHF222GGP
VFHA422GGP

Copyright© 2006 Cooper Crouse-Hinds

VFA222GBP
VFHBF222GBP
VFHF222GBP
VFHA422GBP

941

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0942-9 Name: 11L-942

11L

100:
DATE: JAN 19 2006

Time: 6:02:56 PM Operator: RB

HazardɀGard EX Series
Visual Signaling Devices
Explosionproof Fire Alarm Strobe Light

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Class I, Division 1, Groups C & D
Class I, Zone 1 & 2, Group IIB
Class II, Division 1, Groups E,F,G ɀ Class III
UL 1638, 1203 and 1971 Listed
NEMA 4X watertight, IP 66

The HazardɀGard TM EXFASC Series is a visual fire alarm signaling device for hazardous areas.
The EXFASC Series strobes are UL 1971 Listed for indoor signaling applications for the hearing
impaired in non-sleeping areas. They are also UL listed for Type 3R, 4X installations. The
strobes are available for pendant, wall and ceiling mounts.
The EXFASC Series Fire Alarm Explosionproof Strobe contains a supervisory diode for use
in fire alarm applications. Under normal operation the diode is reversed biased, meaning it
blocks voltage from being applied to the strobe light and prevents it from lighting. When a
fire-initiating device such as a smoke alarm is activated, the diode’s polarity is reversed through
a fire alarm panel. The diode becomes forward biased, allowing voltage to the device and
activating the strobe.

Primary Applications

ɀ Visual fire alarm signaling device for hazardous areas

Typical Industries

ɀ Energy exploration
ɀ Utilities
ɀ Wastewater treatment plants
ɀ Pulp & paper plants

ɀ Petrochemical plants
ɀ Petroleum refineries
ɀ Oil rigs

Key Features and Benefits

ɀ Meets NFPA requirements for fire safety warning devices.
ɀ State of the art electronic design (full wave rectified design).
- Low current draw is efficient.
- 24VDC regulated full wave rectified
- Limited in-rush current favorable to other fire alarm system
components.
- Proven, reliable circuitry designed specifically for use with fire
alarm control panels.
ɀ Available in pendant, wall and ceiling mount.
ɀ Strobe light produces 65 flashes per minute.
ɀ Factory sealed — no external seals required.
ɀ Quick connect — Strobe fixture threads onto mounting module for
easy installation.
ɀ Small compact size — ceiling mount is 133⁄4-inch long.

Certifications and Compliances

ɀ Class I, Division 1, Groups C & D
ɀ Class I, Zone 1 & 2, Group IIB
ɀ Class II, Division 1, Groups E, F & G
ɀ Class III
ɀ UL 1638 and 1203 Listed
ɀ UL 1971 Listed for indoor visual signaling for the hearing impaired in
non-sleeping areas
ɀ cUL Listed C22.2 No. 205
ɀ NEMA 4X watertight, IP 66

Materials & Finishes

ɀ Body, mounting modules and guard — Copper-free aluminum
ɀ Globe — Heat and impact-resistant glass
ɀ Gaskets — Silicone
ɀ External hardware — Stainless steel
ɀ Internal components — Solid-state electronics in a moistureresistant
and heat-dissipating epoxy
ɀ Epoxy powder coated for corrosion resistance

Ratings

ɀ 16-33VDC
ɀ Operating Current: 1.08 - 0.83 amps
ɀ Peak Candlepower: 800,000

Hub Size

ɀ 3/4-inch NPT pendant, ceiling and wall mount

Ordering Information
STEP 2 Order Mounting Module

STEP 1 Order Strobe Type
Catalog
Lens
NEMA
Number
Voltage
Color
Rating
FIRE ALARM RATED EXPLOSIONPROOF STROBES
EXFASC301/16 33 24VDC regulated
Clear
3R, 4X
full wave rectified

Temperature Performance Data

Catalog
Number
EVMP2
EV22 & EV87
EV22
EVMJ4

Hub
Size
3⁄4⍯
3⁄4⍯
3⁄4⍯
11⁄4⍯

See page 944.

942

STIBOINFO((CRH:66008com:11L:942))
CH0 0 4 F - 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Mounting
Style
Pendant
Wall
Ceiling
Stanchion

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0943-9 Name: 11L-943

100:
DATE: JAN 19 2006

Time: 6:02:57 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Class I, Division 1, Groups C & D
Class I, Zone 1 & 2, Group IIB
Class II, Division 1, Groups E,F,G ɀ Class III
UL 1638, 1203 and 844 Listed
1598A Marine Listed (120VAC and 24VDC only)
NEMA 4X watertight, IP 66

HazardɀGard EX Series
Visual Signaling Devices
Explosionproof Strobe Light

11L

Cooper Crouse-Hinds HazardɀGard EXS and EXDS Series Explosionproof Strobe Lights are
designed for installation indoors and outdoors in locations which are hazardous due to the
presence of flammable vapors or gases, ignitible dusts or ignitible fibers and flyings. The units
are UL listed for Type 3R and 4X installations. The 120V and 24VDC models are Marine Rated.
The strobes are available for pendant, wall, stanchion and ceiling mounts, and come in six
different globe colors.
The EXDS Series is diode polarized for use in electrically supervised circuits. Electrically
supervised circuits are typically used in life-safety or security applications.
Under normal operation the diode is reversed biased, meaning it blocks voltage from being
applied to the strobe and prevents it from lighting. When an initiating device such as a smoke
detector is activated, the diode’s polarity is reversed through a circuit panel. The diode
becomes forward biased, allowing voltage to the device and activating the strobe.

Primary Applications

Certifications and Compliances

ɀ Condition signaling
ɀ Equipment obstruction warning
ɀ Security alert
ɀ Emergency evacuation signaling
ɀ In areas where audible signals cannot be heard

ɀ Class I, Division 1, Groups C & D
ɀ Class I, Zone 1 & 2, Group IIB
ɀ Class II, Division 1, Groups E, F & G
ɀ Class III
ɀ UL and cUL 1638, UL 1203 and UL 844 Listed
ɀ 1598A Marine Listed (120VAC and 24VDC only)
ɀ cUL Listed C22.2 No. 205
ɀ NEMA 4X watertight, IP 66

Typical Industries
ɀ Utility gas plants
ɀ Wastewater treatment plants
ɀ Mining

ɀ Petroleum refineries
ɀ Chemical & petrochemical
ɀ Pulp & paper

Materials & Finishes

Key Features and Benefits
ɀ Strong strobe signal that produces 65 flashes per minute.
ɀ Compact design will not obstruct in low ceiling or small areas.
Ceiling mount is only 133⁄4-inch long.
ɀ Quick connect — Strobe fixture threads onto mounting module for
easy installation.
ɀ Factory sealed — No external seals required.
ɀ Available in pendant, wall, stanchion and ceiling mount.
ɀ Available in six different globe colors — clear, red, blue, amber,
green and magenta.
ɀ Silicone gasket seals out dirt and moisture.

ɀ Body, mounting modules and guard — Copper-free aluminum
ɀ Globe — Heat and impact-resistant glass
ɀ Gaskets — Silicone
ɀ External hardware — Stainless steel
ɀ Internal components — Solid-state electronics in a moistureresistant
and heat-dissipating epoxy
ɀ Epoxy powder coated for corrosion resistance

Ratings
ɀ 120VAC (EXS), 12–48VDC (EXSNM) and 24VDC nominal, voltage
operating range is 16–33VDC (EXDS)
ɀ Operating Current: 0.10 amps at 120VAC
1.2–3.8 amps at 12–48VDC
0.8 amps at 24VDC
ɀ Peak Candlepower: 800,000

Hub Size
ɀ 3/4-inch NPT pendant, ceiling and wall mount
ɀ 11⁄4-inch NPT stanchion mount

US: 1-866-764-5454

STIBOINFO((CRH:66008com:11L:943))
CH0 0 4 F - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

943

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0944-13 Name: 11L-944

11L

DATE: JAN 19 2006

Time: 6:02:58 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Class I, Division 1, Groups C & D
Class I, Zone 1 & 2, Group IIB
Class II, Division 1, Groups E,F,G ɀ Class III
UL 1638, 1203 and 844 Listed
1598A Marine Listed (120VAC and 24VDC only)
NEMA 4X watertight, IP 66

HazardɀGard EX Series
Visual Signaling Devices
Explosionproof Strobe Light

Ordering Information
STEP 2 Order Mounting Module

STEP 1 Order Strobe Type
Catalog
Number
Voltage
EXPLOSIONPROOF STROBES
EXS301A/120
120VAC
EXS301B/120
120VAC
EXS301C/120
120VAC
EXS301G/120
120VAC
EXS301M/120
120VAC
EXS301R/120
120VAC
EXSNM301A/12 48
12–48VDC
EXSNM301B/12 48
12–48VDC
EXSNM301C/12 48
12–48VDC
EXSNM301G/12 48
12–48VDC
EXSNM301M/12 48
12–48VDC
EXSNM301R/12 48
12–48VDC

Lens
Color

NEMA
Rating

Amber
Blue
Clear
Green
Magenta
Red
Amber
Blue
Clear
Green
Magenta
Red

3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X
3R, 4X
3R, 4X
3R, 4X
3R, 4X
3R, 4X

DIODE POLARIZED EXPLOSIONPROOF STROBES
EXDS301A/24
24VDC
Amber
EXDS301B/24
24VDC
Blue
EXDS301C/24
24VDC
Clear
EXDS301G/24
24VDC
Green
EXDS301M/24
24VDC
Magenta
EXDS301R/24
24VDC
Red

3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine

Catalog
Number
EVMP2
EV22 & EV87
EV22
EVMJ4

Hub
Size
3⁄4⍯
3⁄4⍯
3⁄4⍯
11⁄4⍯

Mounting
Style
Pendant
Wall
Ceiling
Stanchion

Temperature Performance Data
Ambient
Max.
Temp.
40°C
55°C

Supply
Wire
75°C
90°C

Class I
Div. 1, 2
Group C, D
Class I, Zone 1
Group II B
T6(85°C)
T5(100°C)

EXS Series Strobe Light
Voltage 120VAC
(Marine Listed)

40°C
55°C
65°C

75°C
90°C
105°C

T6(85°C)
T6(85°C)
T6(85°C)

T4A(120°C)
T4(135°C)
T4(135°C)

T4A(120°C)
T4(135°C)
T4(135°C)

EXSNM Series Strobe Light
Voltage 12-48 VDC
(Not Marine Listed)

40°C
55°C
65°C

75°C
90°C
105°C

T6(85°C)
T6(85°C)
T6(85°C)

T4A(120°C)
T4(135°C)
T4(135°C)

T4A(120°C)
T4(135°C)
T4(135°C)

EXDS Series Strobe Light-Diode Polarized
Voltage 24 VDC
(Marine Listed)

40°C
55°C

75°C
90°C

T6(85°C)
T5(100°C)

T4A(120°C)
T4(135°C)

T4A(120°C)
T4(135°C)

EXFASC Series Fire Alarm
Voltage 24VDC Regulated
Full Wave Rectified
(Operating Range 16-33VDC)
(Marine Listed)

944

STIBOINFO((CRH:66008com:11L:944))
CH0 0 4 F - 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Class II, Class III
Div. 1
Group E, F, G
T4A(120°C)
T4(135°C)

Class II, Class III
Div. 2
Group F, G
T4A(120°C)
T4(135°C)

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0945-10 Name: 11L-945

DATE: JAN 19 2006

Time: 6:02:59 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Class I, Division 1, Groups C & D
Class I, Zone 1 & 2, Group IIB
Class II, Division 1, Groups E,F,G ɀ Class III
UL 1638, 1203 and 844 Listed
1598A Marine Listed
NEMA 4X watertight, IP 66

HazardɀGard EX Series
Visual Signaling Devices
Explosionproof Steady-On Beacons

csm no.: 100

11L

Cooper Crouse-Hinds HazardɀGard EXSO and EXDSO (Diode Polarized)
Series Explosionproof Steady On Beacons are designed for installation in
hazardous locations where a visual signal is required for tough environmental
conditions involving corrosives, water, dust and extreme temperature.
The units are UL listed for Type 3R, 4X and marine installations. The steady-on
beacons are available for pendant, wall, stanchion and ceiling mounts, and
come in six different globe colors.
Typical industrial and commercial applications include food processing plants,
refineries, mines, tankers, laboratories, sewage treatment plants, off-shore oil
rigs, water and filtration plants and chemical plants.
The diode polarized steady-on beacon is used in electrically supervised circuitry
for life-safety or security applications.

Primary Applications
ɀ Safety lighting
ɀ Continuous source to
ɀ Exit or entrance lights
communicate
ɀ Obstacle warning
ɀ For identifying the location of safety equipment such as
showers or emergency telephones

Typical Industries
ɀ Chemical plants
ɀ Storage handling
ɀ Dust conveyor systems

ɀ Energy exploration
ɀ Textile mills
ɀ Flour and feed mills

Key Features and Benefits
ɀ Powerful halogen light source for clear visual indication.
ɀ Available in six different globe colors — amber, blue, clear,
green, magenta and red.
ɀ Factory sealed — no external seals required.
ɀ Quick connect — Steady-on beacon fixture threads onto mounting
module
for easy installation.
ɀ Small compact size — ceiling mount is 133⁄4-inch long.
ɀ Available in pendant, wall, stanchion and ceiling mount.

Certifications and Compliances
ɀ Class I, Division 1, Groups C & D
ɀ Class I, Zone 1 & 2, Group IIB
ɀ Class II, Division 1, Groups E, F & G
ɀ Class III
ɀ UL and cUL 1638, UL 1203 and UL 844 Listed
ɀ 1598A Marine Listed
ɀ NEMA 4X watertight, IP 66

Materials & Finishes
ɀ Body, mounting modules and guard — Copper-free aluminum
ɀ Globe — Heat and impact-resistant glass
ɀ Gaskets — Silicone
ɀ External hardware — Stainless steel
ɀ Internal components — Solid-state electronics in a moistureresistant
and heat-dissipating epoxy
ɀ Epoxy powder coated for corrosion resistance

Ratings
ɀ 120VAC and 24–28VDC
ɀ Operating Current: 0.35 amps at 120VAC (EXSO)
0.8 amps at 24–28VDC (EXDSO, diode polarized)
ɀ Peak Candlepower: 3328

Hub Size
ɀ 3/4-inch NPT pendant, ceiling and wall mount
ɀ 11⁄4-inch NPT stanchion mount

US: 1-866-764-5454

STIBOINFO((CRH:66008com:11L:945))
CH0 0 4 F - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

945

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0946-8 Name: 11L-946

11L

DATE: JAN 19 2006

Time: 6:03:00 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Class I, Division 1, Groups C & D
Class I, Zone 1 & 2, Group IIB
Class II, Division 1, Groups E,F,G ɀ Class III
UL 1638, 1203 and 844 Listed
1598A Marine Listed
NEMA 4X watertight, IP 66

HazardɀGard EX Series
Visual Signaling Devices
Explosionproof Steady-On Beacons

Ordering Information
STEP 2 Order Mounting Module

STEP 1 Order Steady-On Beacon Type
Catalog
Lens
Number
Voltage
Color
EXPLOSIONPROOF STEADY-ON BEACONS
EXSO301A/120
120VAC
Amber
EXSO301B/120
120VAC
Blue
EXSO301C/120
120VAC
Clear
EXSO301G/120
120VAC
Green
EXSO301M/120
120VAC
Magenta
EXSO301R/120
120VAC
Red

NEMA
Rating

Catalog
Number
EVMP2
EV22 & EV87
EV22
EVMJ4

3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine

Hub
Size
3⁄4⍯
3⁄4⍯
3⁄4⍯
11⁄4⍯

Mounting
Style
Pendant
Wall
Ceiling
Stanchion

DIODE POLARIZED EXPLOSIONPROOF STEADY-ON BEACONS
EXDSO301A/24 28
24–28VDC
Amber
3R, 4X, Marine
EXDSO301B/24 28
24–28VDC
Blue
3R, 4X, Marine
EXDSO301C/24 28
24–28VDC
Clear
3R, 4X, Marine
EXDSO301G/24 28
24–28VDC
Green
3R, 4X, Marine
EXDSO301M/24 28
24–28VDC
Magenta
3R, 4X, Marine
EXDSO301R/24 28
24–28VDC
Red
3R, 4X, Marine

Temperature Performance Data

EXSO Series Steady-On Beacon
Voltage 120VAC
EXDSO Series Steady-On Beacon — Diode Polarized
Voltage 24-28 VDC

946

STIBOINFO((CRH:66008com:11L:946))
CH0 0 4 F - 5

US: 1-866-764-5454

Ambient
Max.
Temp.
40°C
55°C
65°C
40°C
55°C
65°C

CAN: 1-800-265-0502

Supply
Wire
75°C
90°C
105°C
75°C
90°C
105°C

Class I
Div. 1, 2
Group C, D
Class I, Zone 1
Group II B
T6(85°C)
T5(100°C)
T5(100°C)
T6(85°C)
T6(85°C)
T6(85°C)

Class II, Class III
Div. 1
Group E, F, G
T4A(120°C)
T4(135°C)
T4(135°C)
T4A(120°C)
T4(135°C)
T4(135°C)

Copyright© 2006 Cooper Crouse-Hinds

Class II, Class III
Div. 2
Group F, G
T4A(120°C)
T4(135°C)
T4(135°C)
T4A(120°C)
T4(135°C)
T4(135°C)

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0947-7 Name: 11L-947

100:
DATE: JAN 19 2006

Time: 6:03:01 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Class I, Division 1, Groups C & D
Class I, Zone 1 & 2, Group IIB
Class II, Division 1, Groups E,F,G ɀ Class III
UL 1638, 1203 and 844 Listed
1598A Marine Listed
NEMA 4X watertight, IP 66

HazardɀGard EX Series
Visual Signaling Devices
Explosionproof Rotating Beacons

11L

Cooper Crouse-Hinds HazardɀGard EXR Series Explosionproof Rotating Beacons are
designed for installation in hazardous locations, such as manufacturing plants, heavy industrial
facilities, refineries, chemical, petrochemical, pharmaceutical and off-shore drilling platforms.
The units are UL listed for Type 3R, 4X and marine installations. The rotating beacons are
available for pendant, wall, stanchion and ceiling mounts, and come in six different globe
colors.
The EXDR Series Explosionproof Rotating Beacon is diode polarized for use in standard
24–28VDC electrical circuits or in electrically supervised circuits. Electrically supervised circuits
are typically used in life-safety or security applications.
Under normal operation in an electrically supervised circuit, the diode is reversed biased,
meaning it blocks voltage from being applied to the rotating beacon and prevents it from
lighting. When a warning detecting device is activated, the diode’s polarity is reversed through
a circuit panel. The diode becomes forward biased, allows voltage to the device and activates
the rotating beacon.

Primary Applications
ɀ Security alert
ɀ Obstacle warning
ɀ Areas under construction
or off limits

Certifications and Compliances
ɀ Equipment obstruction warning
ɀ Status indication of a process
ɀ Supplement audible signaling

Typical Industries
ɀ Utility gas plants
ɀ Wastewater treatment plants
ɀ Chemical plants

ɀ Pharmaceutical plants
ɀ Refineries
ɀ Mining

Key Features and Benefits
ɀ Powerful halogen rotating beacon emits bright light to provide
critical visual warning.
ɀ Available in pendant, wall, stanchion and ceiling mount.
ɀ Available in six different globe colors — amber, blue, clear,
green, magenta and red.
ɀ Beacon produces 75 rotations per minute.
ɀ Factory sealed — No external seals required.
ɀ Quick connect — Strobe fixture threads onto mounting module for
easy installation.

ɀ Class I, Division 1, Groups C & D
ɀ Class II, Division 1, Groups E, F & G
ɀ Class I, Zone 1 & 2, Group IIB
ɀ Class III
ɀ UL and cUL 1638, UL 1203 and UL 844 Listed
ɀ 1598A Marine Listed
ɀ NEMA 4X watertight, IP 66

Materials & Finishes
ɀ Body, mounting modules and guard — Copper-free aluminum
ɀ Globe — Heat and impact-resistant glass
ɀ Gaskets — Silicone
ɀ External hardware — Stainless steel
ɀ Internal components — Solid-state electronics in a moistureresistant
and heat-dissipating epoxy
ɀ Epoxy powder coated for corrosion resistance

Ratings
ɀ 120VAC (EXR) and 24–28VDC (EXDR)
ɀ Operating Current: 0.382 amps at 120VAC
0.8 amps at 24–28VDC
ɀ Peak Candlepower: 3328 (EXR)
2838 (EXDR)

Hub Size
ɀ 3⁄4-inch NPT pendant, ceiling and wall mount
ɀ 11⁄4-inch NPT stanchion mount

US: 1-866-764-5454

STIBOINFO((CRH:66008com:11L:947))
CH0 0 4 F - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

947

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0948-13 Name: 11L-948

11L

DATE: JAN 19 2006

Time: 6:04:07 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Class I, Division 1, Groups C & D
Class I, Zone 1 & 2, Group IIB
Class II, Division 1, Groups E,F,G ɀ Class III
UL 1638, 1203 and 844 Listed
1598A Marine Listed
NEMA 4X watertight, IP 66

HazardɀGard EX Series
Visual Signaling Devices
Explosionproof Rotating Beacons

Ordering Information
STEP 2 Order Mounting Module

STEP 1 Order Rotating Beacon Type
Catalog
Lens
Number
Voltage
Color
EXPLOSIONPROOF ROTATING BEACONS
EXR301A/120
120VAC
Amber
EXR301B/120
120VAC
Blue
EXR301C/120
120VAC
Clear
EXR301G/120
120VAC
Green
EXR301M/120
120VAC
Magenta
EXR301R/120
120VAC
Red

NEMA
Rating

Catalog
Number
EVMP2
EV22 & EV87
EV22
EVMJ4

3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine
3R, 4X, Marine

Hub
Size
3⁄4⍯
3⁄4⍯
3⁄4⍯
11⁄4⍯

Mounting
Style
Pendant
Wall
Ceiling
Stanchion

DIODE POLARIZED EXPLOSIONPROOF ROTATING BEACONS
EXDR301A/24 28
24–28VDC
Amber
3R, 4X, Marine
EXDR301B/24 28
24–28VDC
Blue
3R, 4X, Marine
EXDR301C/24 28
24–28VDC
Clear
3R, 4X, Marine
EXDR301G/24 28
24–28VDC
Green
3R, 4X, Marine
EXDR301M/24 28
24–28VDC
Magenta
3R, 4X, Marine
EXDR301R/24 28
24–28VDC
Red
3R, 4X, Marine

Temperature Performance Data

EXR Series Rotating Beacon
Voltage 120VAC
EXDR Series Rotating Beacon — Diode Polarized
Voltage 24-28 VDC

948

STIBOINFO((CRH:66008com:11L:948))
CH0 0 4 F - 5

US: 1-866-764-5454

Ambient
Max.
Temp.
40°C
55°C
65°C
40°C
55°C
65°C

CAN: 1-800-265-0502

Supply
Wire
75°C
90°C
105°C
75°C
90°C
105°C

Class I
Div. 1, 2
Group C, D
Class I, Zone 1
Group II B
T6(85°C)
T5(100°C)
T5(100°C)
T6(85°C)
T6(85°C)
T6(85°C)

Class II, Class III
Div. 1
Group E, F, G
T4A(120°C)
T4(135°C)
T4(135°C)
T4A(120°C)
T4(135°C)
T4(135°C)

Copyright© 2006 Cooper Crouse-Hinds

Class II, Class III
Div. 2
Group F, G
T4A(120°C)
T4(135°C)
T4(135°C)
T4A(120°C)
T4(135°C)
T4(135°C)

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0949-19 Name: 11L-949

DATE: JAN 19 2006

Time: 6:04:08 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

HazardɀGard EX Series
Visual Signaling Devices

csm no.: 100

11L

Dimensions & Weights

Stanchion Mount

NET LUMINAIRE WEIGHTS

US: 1-866-764-5454

STIBOINFO((CRH:66008com:11L:949))
CH0 0 4 F - 5

Luminaire Housing with Guard

11.0 lbs.

Add mounting modules
Pendant
Ceiling
Wall
Stanchion

1.0 lbs.
1.0 lbs.
4.5 lbs.
2.5 lbs.

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

949

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0950-2 Name: 11L-950

11L

100:
DATE: JAN 19 2006

Time: 6:04:09 PM Operator: JB COLOR: CMYK

TCP: 15001

ɀ

ɀ

ɀ

ɀ

Cl. I, Div. 2, Groups A, B, C, D
Cl. I, Zone 2, Group IIC
ɀ Cl. II, Div 2, Groups F, G; Cl. III

VDAS Strobe Lights
Warning and Visual
Indication

Application:

Typedriver Name: TS name csm no.: 100

Wet Locations
3, 3R, 4, 4X

CSA Enclosure 3, 4, 5
Replacement Parts

VDAS strobe lights are used:
ɀ in areas with high noise levels
ɀ to visually indicate warnings or hazards

Electronic Strobe Subassembly
(includes flash tube):
120 VAC. . . . . . . . . . . . . . . . . . . . . . CHTFI-120H
240 VAC . . . . . . . . . . . . . . . . . . . . . CHTFI-240H
12 VDC . . . . . . . . . . . . . . . . . . . . . . . . CHTFI-012
24 VDC. . . . . . . . . . . . . . . . . . . . . . . . CHTFI-024
Flash Tube . . . . . . . . . . . . . . . . . . . . . . . . RSTC
Globe Assembly
Clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/C
Red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/R
Green . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/G
Amber . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/A
Blue. . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/B

Features:
ɀ Reliable solid state components.
ɀ Compact enclosure design provides 60
high intensity flashes per minute.
ɀ Choice of globe colors to meet various
requirements.
ɀ Gasketed to seal out dirt and liquids.
ɀ Designed for globe up or globe down
applications.
ɀ Easy to install.
ɀ Lightweight corrosion-resistant copper-free
aluminum construction.
ɀ Conduit locking hub for increased safety
and security.

Standard Materials:
ɀ Body – copper-free aluminum
ɀ Globe – LEXAN® fresnel lens

Ordering Information

Standard Finishes:

Globe
Color

ɀ Body – gray epoxy

Size Range:

Red
Blue
Amber
Green
Clear

ɀ 3⁄4⍯ conduit

Certifications and
Compliances:
ɀ NEC and CEC:
Class I, Division 2,
Groups A, B, C, D
Class I, Zone 2, IIC
ɀ UL Standards
844
1598 Luminaires
ɀ CSA Standards
C22.2 No. 137

Pendant
Hub Size
3⁄4⍯
3⁄4⍯
3⁄4⍯
3⁄4⍯
3⁄4⍯

Cat. #
120 VAC
VDAS/R
VDAS/B
VDAS/A
VDAS/G
VDAS/C

Temperature Performance
Data:
Ambient
°C
40°
55°
65°

Electrical Ratings:

Class I
Div 2
T3B
T3A
T3

Cat. #
240 VAC
VDAS/R/240
VDAS/B/240
VDAS/A/240
VDAS/G/240
VDAS/C/240

Dimensions

Class II
Div 2, Class III
T3B
-----

ɀ 120, 240 VAC 50/60 Hz
ɀ 12, 24 VDC

Photometric Data, Clear
Globe
ɀ Peak flash – 3.45 million candlepower
ɀ Effective candlepower (light intensity if light
is burning steadily) – 201 ECP

Photometric Data:
Globe Color
Output Intensity
Clear . . . . . . . . . . . . . . . . . . . . . . . 201
ECP
Red . . . . . . . . . . . . . . . . . . . . . . . . . 46
ECP
Amber. . . . . . . . . . . . . . . . . . . . . . 152
ECP
Blue. . . . . . . . . . . . . . . . . . . . . . . . . 38
ECP
Green . . . . . . . . . . . . . . . . . . . . . . . 38
ECP

Operating Current:
Voltage
120 VAC
240 VAC
12 VDC
24 VDC

950

STIBOINFO((CRH:66008com:11L:950))
CH0 1 1 L - 8

Operating Current
.3A
.15A
.9A
.45A

US: 1-866-764-5454

CAN: 1-800-265-0502

Cat. #
12 VDC
VDAS/R/012
VDAS/B/012
VDAS/A/012
VDAS/G/012
VDAS/C/012

Copyright© 2006 Cooper Crouse-Hinds

Cat. #
24 VDC
VDAS/R/024
VDAS/B/024
VDAS/A/024
VDAS/G/024
VDAS/C/024

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0951-4 Name: 12L-951

DATE: JAN 19 2006

Time: 6:04:10 PM Operator: RB

COLOR: CMYK

TCP: 15001

Specialty Lighting

Typedriver Name: TS name csm no.: 100

12L

Tank, Task and Gauge Lighting
Hazardous and Non-Hazardous Locations

Description

Page No.

Application/Selection

952

Gauge Light

958

Tank Light

953, 954

V160
EVA160

Task Light

955-957

EVTL1B50
EVTL1L50

US: 1-866-764-5454

STIBOINFO((CRH:66008com:12L:951))
CH0 0 0 0 2 L

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

951

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0952-4 Name: 12L-952

12L

100:
DATE: JAN 19 2006

Time: 6:04:11 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Specialty Lighting
Tank, Task and Gauge
Hazardous and Non-Hazardous Locations
Application and Selection

Application:
Specialty lighting luminaires are used:
ɀ for various task lighting requirements in
locations that are hazardous (classified) due
to the presence of combustible dusts or
easliy ignitible fibers and flyings
ɀ in areas where conventional lighting is not
acceptable due to size and/or location
ɀ in locations where an adequate light source
is necessary for tank, instrument, and gauge
applications
ɀ in manufacturing plants, refineries,
pharmaceutical, chemical, petrochemical,
and other industrial process facilities, waste
or sewage treatment facilities, grain
processing and handling facilities and other
heavy industrial applications

952

STIBOINFO((CRH:66008com:12L:952))
CH0 2 L - 1 2

Considerations for
Selection:
Environmental:
ɀ What is the hazardous area classification
(NEC)/(CEC) of the location in which the
luminaire will be installed?
Lighting levels required:
ɀ What wattage luminaire(s) will provide the
desired light level (See lighting Selector
Guide, pages 665 through 689, to determine
number and location of fixture required).
Physical Arrangement:
ɀ Type of fixture mounting needed.

US: 1-866-764-5454

CAN: 1-800-265-0502

Product Selection:
ɀ EV Tank Lights are suitable for use in Class
I, Groups C, D hazardous (classified)
locations. Tank lights are used to light the
inside of tanks, vats, process vessels, etc.
ɀ EVTL Explosionproof Task Lights are
suitable for use in Class I, Group B, C, D and
Class II, Groups E, F, G hazardous
(classified) locations. EVTL Lights are ideal
for applications in which water spray and
corrosive atmospheres are considerations.
ɀ ELG gauge lights are suitable for use in
Class I, Groups C, D hazardous (classified)
locations. The light is used to illuminate liquid
level gauges and to direct the light over the
length of the column.

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0953-2 Name: 12L-953

DATE: JAN 19 2006

Time: 6:04:12 PM Operator: JB COLOR: CMYK

TCP: 15001

Watertight

V Observation Incandescent
Luminaire

Typedriver Name: TS name csm no.: 100

12L

Application:
The incandescent V observation luminaire is
used:
ɀ in tanks or kettles where food is processed
ɀ to light the inside of tanks for observation of
the contents through a window

Features:
ɀ Watertight
ɀ Supported by a mounting ring which
contains holes for riveting when placed
around a hole in the tank. It can also be
welded or brazed to the tank.
ɀ Heavy heat and impact-resistant glass
globe eliminates breakage and resultant
contamination of food from glass particles
ɀ Relamping is easily accomplished by
removal of the two thumb-screws which
fasten the body to the mounting ring
ɀ The flexible cord or cable should be
connected by an EC flexible coupling or CG
Series connector

Standard Materials:
ɀ Mounting ring – silicon bronze
ɀ Fixture body – Feraloy® iron alloy
ɀ Globe – heat-resisting glass

Furnished with EV10 Globe, and
C166 Medium Base Lamp Receptacle
Hub
Lamp
Size
1⁄2

Standard Finishes:
Feraloy – electrogalvanized and aluminum
acrylic paint
ɀ Bronze – natural

Size
50, 60,
75 or
100W,
A-21

Cat. #
V160

Dimensions

Size Ranges:
ɀ Up to 100 watt, A-21 lamp

Certifications and
Compliances:
ɀ UL Standard: 1571
ɀ CSA Standard: C22.2

US: 1-866-764-5454

STIBOINFO((CRH:66008com:12L:953))
CH0 1 L - 1 9

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

953

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0954-2 Name: 12L-954

12L

DATE: JAN 19 2006

Time: 6:04:13 PM Operator: JB COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 & 2, Groups C, D
Cl. I, Zone I & 2 IIB
Cl. II, Div. 1, Groups E, F, G – EVO only

EV Tank Luminaires

Application:

Dimensions

EV tank light luminaires are used:
ɀ to light inside of tanks, vats, process
vessels, etc.
ɀ in chemical plants, petrochemical plants
and petroleum process industries
ɀ suspended over tank porthole by EC
flexible hanger (EVO style)
ɀ mounted directly in tank wall (EVA)

EVO2376

Features:
ɀ High light output
ɀ Compact design
EVA160:
ɀ Furnished with tank ring having eight
3⁄16⍯ holes for riveting to tank
ɀ Can be brazed if desired
ɀ Luminaire ring is attached to the tank ring
by eight 1/4-20 Allen Head cap screws
ɀ Luminaire attached to luminaire ring by four
wing screws
ɀ EC flexible luminaire support should be
used so relamping can be accomplished
without disturbing the globe

EVO2376

EVA160

Standard Materials:
ɀ Bodies – EVA: Receptacle housing and
intermediate ring – Feraloy® iron alloy. Tank
ring – silicon bronze; EVO: copper-free
aluminum
ɀ Globes: EVA – glass, heat and impact
resistant; EVO – glass, heat strengthened
plate glass

Standard Finishes:
ɀ Feraloy iron alloy – cadmium
electrogalvanized and aluminum acrylic
paint; copper-free aluminum – aluminum
acrylic paint; silicon bronze – natural

EVA160

ɀ 1⁄2⍯ and 3⁄4⍯ hubs

Watts
75

Capacity Ranges:

100, A-21

Size Ranges:
ɀ EVO – 75 watt, reflector spot max.
ɀ EVA – 100 watt, A-21 max.

Lamp (not furnished)
75R 30/SP reflector spot
(medium base)
Medium base

Certifications and
Compliances:

Hub
Size
1⁄2 & 3⁄4

Cat. #
EVO2376

1⁄2

EVA160

Tank Ring Mounting (EVA160)

ɀ NEC:
Class I, Division 1 and 2, Groups C, D –
EVO and EVA
Class II, Division 1, Groups E, F, G –
EVO only
ɀ UL Standard: 844

Temperature Performance
Data: (based on 40°C Ambient)
Class I
Class II
Groups C, D
Groups E, F, G
EVO2376
T3C
T3C
EVA160
T3C*
—
*All mounting positions

954

STIBOINFO((CRH:66008com:12L:954))
CH0 2 L - 1 2

Supply
Wire (°C)
75
75

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0955-4 Name: 12L-955

DATE: JAN 19 2006

Time: 6:04:14 PM Operator: JB COLOR: CMYK

EVTL
Explosionproof Task Light

Class I Groups B, C, D
Class I Zone I, IIB+H2
Class II Groups E, F, G
Class III Simultaneous Service

TCP: 15001

Typedriver Name: TS name csm no.: 100

Wet Locations
Marine Locations
NEMA 3, 3R, 4, 4X

12L

Application
EVTL task light luminaires are used:
ɀ For various task lighting requirements in locations
that are hazardous (classified) due to the presence
of flammable gases or vapors, combustible dusts or
easily ignitible fibers & flyings.
ɀ in marine applications where water spray and
corrosive atmospheres are considerations.
ɀ in areas where conventional lighting is not
acceptable due to size and/or location.
ɀ in locations where an adequate light source is
necessary for tank, instrument, and gauge
applications.
ɀ in porthole or sightglass applications where a
spotlight is required for visibility inside tanks, vats
and process vessels.
ɀ in manufacturing plants, refineries,
pharmaceutical, chemical, petrochemical, and other
industrial process facilities, waste or sewage
treatment facilities, grain processing and handling
facilities and other heavy industrial applications.

EVTL1B50

EVTL1L50

Key Features

Benefits

Class I, II, III, Simultaneous
Presence

Suitable for most hazardous (classified) areas

ɀ Housing—Copper-free aluminum
ɀ 3⁄4⍯ NPT hub and plug—Aluminum
ɀ Mounting bracket(s) and External hardware—
Stainless Steel
ɀ Gasket—Silicone rubber
ɀ Lens—Heat and impact resistant clear glass

Class I Group B standard

Suitable for areas containing hydrogen

Wet and Marine (NEMA 4X)
Suitability

Perfect for hose down applications

55° ambient suitability

Standard Finishes:

Addresses higher ambients typical of industrial
plants.
Superior corrosion resistance

Cast copper-free aluminum
housing with Corro-free TM epoxy
powder coat finish.
Stainless steel mounting
Superior corrosion resistance
brackets and hardware.
Two mounting styles bracket
Maximize mounting flexibility
and leg
ɀ Bracket (Universal)
Ceiling, Wall or Base mounting
ɀ Leg (Site Glass)
Site Glass mounting
Uses standard 50 watt PAR 20
Improved light output, economical, long life
medium base 120V lamps
2000-2500 hour light source
Uses 50PAR20 130V lamps for
Increase lamp life to 5000+ hours while
added lamp life
maintaining 76% lumen output
50PAR20 lamps available in both
Vary the illumination characteristics by simply
flood and spot light patterns
changing lamps
Easy access interior
Reduced maintenance and lamp replacement time
Seal within 5 ft. (not 18⍯) of
Provides greater flexibility in seal location
luminaire

Standard Materials:

ɀ Aluminum housing (exterior)—Corro-free epoxy
powder coat
ɀ Stainless Steel—Natural

Ratings (Electrical/Size)
Source/Wattage (Medium Base Lamps)
ɀ 50PAR20 type—50W 120V halogen parabolic
reflector. Lamp life 2000-2500 hrs.
ɀ 130V lamps available to extend lamp life to 5000+
hrs.

Voltage
ɀ 120V 60 Hz

Hub Size
ɀ (1) 1⁄2⍯ NPT
ɀ For through feed, use EVTL-TF1

Certifications and Compliances:
ɀ NEC/CEC
ɀ
ɀ
ɀ
ɀ
ɀ
ɀ
ɀ

Class I Division 1 & 2 Groups B, C, D
Class II Group E, F, G
Class III
Class I Zone 1 & 2 Group IIB + H2
Wet locations
Marine locations
NEMA 4X

ɀ NEC

Ordering Information:
Luminaire Cat. #
EVTL1B50
EVTL1L50

Conduit Entry
1⁄2⍯
1⁄2⍯

844—Hazardous (Divisions Classified) Locations
1571—Ordinary and Wet Locations, Marine
Outside Type

CSA Standards

Wattage
50
50

Temperature Performance Data:

ɀ Simultaneous Presence

UL Standards

Mounting Style
Bracket (Universal)
Leg (Site Glass)

Catalog
Number
EVTL1B50
EVTL1L50

°C
40
40

Maximum
Ambient

Class I, Div, 1, B, C, D
Class II, Div. 1, E, F, G
Class III
Simultanenous Presence
Class I, Zone 1, IIB + H2
T3B
T3B

Supply
Wire °C
85
85

C22.2 No. 137
Note: Install luminaire within aiming ranges shown on nameplate (See
Dimensions)

US: 1-866-764-5454

STIBOINFO((CRH:66008com:12L:955))
CH0 2 L - 1 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

955

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0956-3 Name: 12L-956

12L

100:
DATE: JAN 19 2006

Time: 6:04:15 PM Operator: JB COLOR: CMYK

EVTL
Explosionproof Task Light

TCP: 15001

Dimensions and Weights

Aiming Range

Dimensions: Bracket Mount

Dimensions: Leg Mount

Net Luminaire Weights (lbs)
Luminaire Catalog
Weight (lbs.)

EVTL1B50

7

EVTL1L50

7

EVTL-TF1

1⁄2

956

STIBOINFO((CRH:66008com:12L:956))
CH0 2 L - 1 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Typedriver Name: TS name csm no.: 100

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0957-3 Name: 12L-957

100:
DATE: JAN 19 2006

Time: 6:04:16 PM Operator: JB COLOR: CMYK

EVTL
Explosionproof Task Light

TCP: 15001

Photometric Data:

Typedriver Name: TS name csm no.: 100

12L

Lamp Light Distribution – (Philips lamp data shown. Similar for other manufacturers)
Data shown is for 120 volt lamps
For 130 volt lamps adjust data using a .76 multiplier

US: 1-866-764-5454

STIBOINFO((CRH:66008com:12L:957))
CH0 2 L - 1 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

957

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0958-5 Name: 12L-958

12L

DATE: JAN 19 2006

Time: 6:04:17 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Cl. I, Div. 1 & 2, Groups C, D
Cl. 1, Zone 1 & 2 IIB
Explosionproof

ELG Gauge Luminaires

Application:
ELG Gauge lights are used:
ɀ in hazardous areas to illuminate liquid level
gauges over entire length of gauge
ɀ clamped to rear of liquid level gauge and
conduit is attached to the ELG hubs. Light is
reflected by Lucite reflector along the entire
length of the gauge. Liquid level shows on
front of gauge. All light is concentrated on
liquid column – no spill light.

Features:
ɀ Even illumination over entire length of
gauge
ɀ Variety of sizes to fit many gauges
ɀ Several lights can be used in tandem to
illuminate long gauge

Standard Materials:
ɀ Body – copper-free aluminum
ɀ Reflectors – plexiglass

Standard Finishes:
ɀ Body – electrogalvanized and aluminum
acrylic paint
ELG329 with LE49 reflector

Size Ranges:
ɀ 1⍯ conduit through feed

Dimensions

Capacity Ranges:
ɀ 120V medium screw base ‘‘A19’’ style
incandescent lamp 58W maximum
ɀ 25 watt – medium base – 1000 hour life
ɀ 52 watt – medium base – 2500 hour life
ɀ 58 watt – medium base – 3000 hour life

Certifications and
Compliances:
ɀ NEC/CEC:
Class I, Division 1 and 2, Groups C, D

Ordering Information:
Description
Gauge Light
(less reflector)
Reflector
– Short style
Reflector
– Long style

Temperature Performance
Data: (based on 40°C ambient)
58 Watt – T4A
Maximum

Catalog No.

Length (L)
(inches)

ELG329
LE34
LE35
LE46
LE47
LE48
LE49
LE410
LE412
LE413

—
41⁄2
51⁄2
13
15
17
193⁄4
22
251⁄4
263⁄4

Plexiglass reflectors
Short style

Long style

Options:
Suffix to be
Description
Added to Cat. No.
ɀ Group B suitability . . . . . . . . . . . . . . . . . . GB

Suggested Lamps (Lamps not furnished)
Manufacturer
General Electric
Osram/Sylvania
Philips

958

STIBOINFO((CRH:66008com:12L:958))
CH0 2 L - 1 1

25 Watt
25A
25A
25A

Catalog Number
52 Watt
58 Watt
60A/52WMP/98
60A/52/SS/XL
58A19/62
60A-52A/99/EW

US: 1-866-764-5454

Volts
120
120
120

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : 3.1-702
Modify Date                     : 2010:02:11 15:31:08+07:00
Create Date                     : 2010:02:11 15:30:29+07:00
Metadata Date                   : 2010:02:11 15:31:08+07:00
Creator Tool                    : Adobe Acrobat 6.0
Format                          : application/pdf
Document ID                     : uuid:c59660bc-fc16-4f00-800f-1288691192f6
Instance ID                     : uuid:c9db375b-ce5b-4fab-95ac-5c1df80e46c4
Producer                        : Acrobat Distiller 6.0.1 for Macintosh
Has XFA                         : No
Page Count                      : 298
Creator                         : Adobe Acrobat 6.0
EXIF Metadata provided by EXIF.tools

Navigation menu