109532 Catalog
2014-07-30
: Pdf 109532-Catalog 109532-Catalog 782274 Batch6 unilog
Open the PDF directly: View PDF .
Page Count: 298
Download | |
Open PDF In Browser | View PDF |
2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0661-6 Name: L-661 100: DATE: JAN 19 2006 Time: 5:41:45 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Industrial Lighting Section L 661 STIBOINFO((CRH:66008com:L:661)) CHI NT R OL Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0662-13 Name: L-662 L DATE: JAN 19 2006 Time: 5:41:47 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Industrial Lighting Table of Contents Section L of the Cooper Crouse-Hinds Catalog contains information on industrial lighting. Product details on individual luminaires are given in eleven separate sections, as noted below. In addition, a complete section (8L) is devoted to luminaire hangers and accessories. Considerations for Selection Preceding the eleven product sections is a Selector Guide. Included in this section is information on: ɀ a selection of the appropriate light source for a given application ɀ a Quick Selector Guide of the luminaires that are designed and approved to meet the various environmental requirements of the National Electric Code ɀ determining the proper size (i.e., wattage) and number of units to achieve the desired light levels in a given application ɀ methods to follow in making a luminaire layout. Cat. Nos. are shown, in many cases, for complete assemblies including mounting, reflector, globe, and guard, as well as individual components. In these cases, ordering can be done by component or by complete assembly. Photometric and other technical data is included in each section for the luminaires it contains. Information relating to product families in the Lighting Section is shown as follows: Section 3L High Intensity Discharge (H.I.D.) Lighting— Enclosed and Gasketed (for use in hazardous [classified] locations, non-hazardous locations, and marine locations) Indoor and outdoor vaportight luminaires for use in applications where dirt, moisture, and corrosion problems exist. Included are units with integral ballasts. DMV Champ® Series LMV Champ® Series VMV Champ® Series N2MV Champ® Series Section 4L High Intensity Discharge (H.I.D.) Lighting Indoor and outdoor luminaires and accessories. Included are luminaires with integral ballasts. HazardȿGard® Series LoȿPro HazardȿGard® Series A variety of portable luminaires for hazardous and non-hazardous applications. VS EVH RCDER EVP Section 5L Luminaires with Induction Lighting System (for use in non-hazardous areas; some luminaires have specific hazardous [classified] locations suitability.) Section 6L Fluorescent Lighting (for use in hazardous [classified] locations) Indoor and outdoor luminaires and accessories EV Series EVI Series DMVIG, VMVIG (for use in hazardous [classified] locations and non-hazardous locations) Indoor and outdoor fluorescent luminaires and accessories for application in all classes of hazardous and non-hazardous locations. For hazardous For non-hazardous locations locations CPMVF NFL EVF, EVFDR VF Vaporgard Series FVN, FVS EVFT, DMVF N2MVF, EVLPF VF, ELLK, NLLK eLLB20 Section 7L Floodlights (for use in hazardous [classified] locations and non-hazardous locations) CPMV Champ-Pak TM Wall Pack EVMA-S812 HazardGard® Series FMV Champ® Series F2MV, FMV1000 FZD RCDE SSFMV Voyager nR TM 662 STIBOINFO((CRH:66008com:L:662)) CH0 0 0 L - 0 A variety of luminaire hangers for use with the luminaires listed. Information on mounting accessories required and typical luminaire weights also included. For hazardous For non-hazardous locations locations EAHC, EFHC AL EC AHG EFH ARB GUA, GUF FHM UNR UNE, UNH, UNHC CPS UNJ UNJC Section 9L Portable Lighting (for use in hazardous [classified] locations, non-hazardous locations, and marine locations) Section 2L Incandescent Lighting (for use in hazardous [classified] locations and non-hazardous locations) (for use in hazardous [classified] locations) Section 1L Incandescent Lighting— Enclosed and Gasketed Indoor and outdoor vaportight luminaires and accessories for use in industrial applications where dirt, moisture, and corrosion problems exist. V160 NDA CorroȿGard® Series V Series Vaporgard TM Series Section 8L Luminaire Hangers and Accessories US: 1-866-764-5454 CAN: 1-800-265-0502 Section 10L Emergency Lighting (for use in hazardous [classified] locations)ɍ Emergency lighting for use in power outage situations. Also, exit signs and strobe warning lights. CPMVFB N2LPS Light-Pak TM Series EXL – exit sign DMVFB N2MVFB ELPS Light-Pak TM Series EVLPFB Section 11L Beacons and Strobes Indoor and outdoor luminaires for use in applications where visual signaling is a requirement. For hazardous locations EX Beacons and Strobes VF Beacons VDAS Strobes Section 12L Specialty Lighting Luminaires for use in applications where conventional lighting is not acceptable due to size and/or location, such as tank, instrument, and gauge applications. For hazardous For non-hazardous locations locations EV – tank lights V Observation EVTL ELG – gauge light Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0663-9 Name: L-663 100: DATE: JAN 19 2006 Time: 5:41:47 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Industrial Lighting Products L Quick Reference Chart LIGHT SOURCE WallPacks & Luminaire Floodlights Hangers ɀ Exit Signs ɀ Emergency Lighting ɀ ‘‘Steady On’’ Beacons ɀ Strobes ɀ Pulse Start Metal Halide ɀ Metal Halide ɀ High Pressure Sodium ɀ Mercury Vapor ɀ Incandescent Application Environment Incandescent H.I.D. ɀ Pulse Start Metal Halide ɀ Metal Halide ɀ High Pressure Sodium ɀ Mercury Vapor Fluorescent ɀ Linear ɀ Long Twin Tube ɀ Compact General Industrial Section 1L Vaporgard TM, V Series, NDA Section 12L V160 Tank light Section 3L LMV, DMV, VMV, N2MV Champ® Section 5L Champ Induction Section 6L VF Series, NFL, FVN, FVS DMVF, N2MVF Section 10L N2LPS Light-Pak TM, DMVFB, N2MVFB Section 11L VF ‘‘SO’’ Beacon VDAS Strobe Section 7L F2MV, FMV, FMV1000 Section 8L AL, UNJ, FHM, ARB, UNE, UNH, CHS Wet Locations Section 1L Vaporgard TM , V series, NDA Section 3L LMV, DMV, VMV, N2MV Champ® Section 5L Champ Induction Section 6L VF Series, NFL, FVN, FVS, DMVF, N2MVF Section 10L DMVFB, N2MVFB, N2LPS Light-Pak TM, Section 11L VF ‘‘SO’’ Beacon VDAS Strobe Section 7L F2MV, FMV, FMV1000 Section 8L AHG, ARB–21 series Marine Locations or 4X Section 1L NDA Section 3L LMV, DMV, VMV, N2MV Champ® Section 4L EVLP Lo-Pro EVM Hazard-Gard Section 6L NFL, FVS, DMVF, N2MVF, CPMVF EVFDR, EVFT Illuminator TM Section 10L DMVFB, N2MVFB, Section 11L VDAS Strobe Section 7L CPMV, F2MV, FMV, FMV1000 Corrosive Section 1L Vaporgard TM, NDA Section 3L LMV, DMV, VMV, N2MV Champ® Section 5L Champ Induction Section 6L NFL, N2MVF, FVS, VF Series, DMVF, CPMVF Section 10L DMVF-EXD exit, N2MV-EXD exit, N2LPS Light-Pak TM, N2MVFB, DMVFB Section 11L VF ‘‘SO’’ Beacon VDAS Strobe Section 7L CPMV, F2MV, FMV, FMV1000 Section 8L EFHC-S752 ECHF-S758 ECF-S516 Class I, Div. 1 or Zone 1 Section 2L EV Section 12L EVTL, EVA160, EVO, ELG Section 4L EVLP Lo-Pro EVM Hazard-Gard Section 6L EVF, EVFDR, EVFT Illuminator®, EVLPF, eLLK Section 10L EXL exit, EVLPF-EXD exit, ELPS Light-Pak TM EVLPFB Section 11L EV ‘‘SO’’ Beacon EVAS Strobe Section 7L FZD, EVM-S812, RCDE Section 8L EAHC, EFHC, ECHF, GUA, GUFX, EFHX, CPS, UNR Class I, Div. 2 and Zone 2 Section 1L Vaporgard TM, NDA Section 3L LMV, DMV, VMV, N2MV Champ® Section 5L Champ Induction Section 6L VF Series, NFL, nLLK, eLLK, FVN, FVS, CPMVF, DMVF, N2MVF Section 10L DMVF-EXD exit, N2LPS Light-Pak TM, DMVFB, N2MVFB Section 11L VF ‘‘SO’’ Beacon VDAS Strobe Section 7L CPMV, F2MV, FMV, FMV1000 FZD Section 8L AL, AHG, UNJ, UNJC, ARB, UNE, UNH, COUP Section 3L LMV, DMV, VMV, N2MV Champ® Section 5L Champ Induction Section 6L CPMVF, DMVF, N2MVF Section 10L DMVFB, N2MVFB Section 7L CPMV, F2MV, FMV Section 8L AL, AHG, UNH, UNJC, ARB, UNE, UNH, COUP Section 3L LMV, DMV, VMV, N2NV Champ® Section 4L EVLP Lo-Pro EVM Hazard-Gard Section 5L Champ Induction Section 6L FVN, nLLK, eLLK, FVS, DMVF, N2MVF EVF, EVFDR, EVFT, EVLP Section 10L EXL, N2LPS Light-Pak TM, DMVFB, N2MVFB Section 11L VF ‘‘SO’’ Beacon VDAS Strobe EVAS Strobe Section 7L CPMV Section 8L ECHF, GUA, GUF, GUJ. EAHC, EFHC, AHG (Class II, Div 2) Section 4L EVP Section 6L EVF, EVFT Section 9L EVP Section 9L EVH US: 1-866-764-5454 CAN: 1-800-265-0502 Restricted Breathing ɀ Class I, Div 2 and Zone 2 ɀ Certified IEC Zone 2 Class II Class III Simultaneous Presence Section 2L EV Section 12L EVTL, EVO Paint Spray Portables STIBOINFO((CRH:66008com:L:663)) CH0 0 0 L - 1 Emergency & Warning Section 9L VS, EVH, RCDER Copyright© 2006 Cooper Crouse-Hinds 663 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0664-3 Name: L-664 L 100: DATE: JAN 19 2006 Time: 5:41:48 PM Operator: JB COLOR: CMYK TCP: 15001 Industrial Lighting Products New ideas in industrial lighting, translated into modern equipment design, backed technically by a nationwide sales force, available worldwide through knowledgeable electrical distributors – these are some of the reasons you’ll be light-years ahead when you look to Cooper Crouse-Hinds for industrial lighting products. This Lighting Selector Guide will help you solve many of your lighting problems. For additional assistance on complex projects, call your Cooper Crouse-Hinds representative or distributor. They can provide detailed lighting layouts and recommendations using the most advanced computer and application engineering facilities and techniques. Lighting Selector Guide Below is a simple five-step procedure to help you select the right equipment for a specific job. Typical examples – with illustrations, easy-to-read charts, and layouts – are included to ensure correct results. The five steps are: 1.) Determine Area Lighting Needs and Operational Factors Page 665 When known, proceed to Step 2 2.) Select Type of Lamp Page 666 When known, proceed to Step 3 3.) Select Type of Luminaire Page 668 When known, proceed to Step 4 4.) Calculate Number of Luminaires Required Page 683 When several light sources or systems seem suitable, determine most economical one With Luxicon TM you’ll be able to make ‘light’ work of analyzing the performance of Cooper Crouse-Hinds broad line of industrial luminaires. From exterior/interior layouts to economic performance data, you’ll be able to access and evaluate information needed to design and specify the most efficient and effective lighting system possible. Luxicon TM offers: ɀ Online tutorial ɀ Color output, either text or graphics ɀ Exterior/interior layouts in one program ɀ Daylight lighting analysis ɀ Importing/exporting of any IES file ɀ Importing/exporting of any .DXF CAD file ɀ Detailed architectural feature calculations ɀ Entire Cooper Crouse-Hinds and Cooper Lighting line search ɀ Economic performance/analysis calculations ɀ Database of customers and their projects ɀ Professional output including summary reports, luminaire schedules, calculation results and renderings on multiple pages ɀ Luminaire editing capabilities ɀ Allowances of varying ambient temperature levels 5.) Determine Placement of Luminaires and Make Layout Page 688 664 STIBOINFO((CRH:66008com:L:664)) CH0 0 0 L - 2 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0665-2 Name: L-665 DATE: JAN 19 2006 Time: 5:41:49 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Industrial Lighting Products L 1 Determine Area Lighting Needs and Operational Factors The selection of the proper luminaire/lamp combination and the determination of the number of luminaires required is a function of the desired quantity and quality of light required, together with consideration of any special factors arising from the nature of the work operation. Several aspects of this selection process are discussed below. The conditions will vary from job to job. It is important to consider these conditions if the lighting system is to yield optimum results. A) Determine Illumination Quantity Required The Illuminating Engineering Society in the current IES Lighting Handbook gives a comprehensive listing of footcandle levels recommended for all types of Industrial Lighting. A condensed version of this listing is given in Table I and is presented according to the types of visual tasks encountered. B) Determine Illumination Quality Required Quality of illumination pertains to the distribution of brightness in the visual environment. Care must be taken to avoid discomforting glare within the normal visual field. Luminaires normally selected for lower mounting should be designed to limit brightness below the 45° zone. C) National Electric Code Compliance The National Electric Code delineates some areas as hazardous, depending on materials or atmosphere within an area. The choice of luminaire and lamp is therefore somewhat restricted if the area is classified as hazardous. In hazardous areas, luminaire design and operating temperature of both luminaire and lamp must meet strict limitations. These limitations are detailed under Step 3 of this selection guide. Table 1 / Recommended Levels of Illuminance Illuminance Category Footcandles† Difficult assembly and inspection, color coding, paper manufacturing (Inspection and Rewinder) finishing operations. F 100 to 200 Moderate Moderately difficult assembly and inspection, checking and sorting, service garage repair areas, medium bench work, instrument panel (vertical illumination). E 50 to 100 Casual Simple assembly, rough bench work, grinding, simple inspection, wrapping, packing and labeling, control house general lighting. D 20 to 50 Easy Rough active storage, washrooms, dry lumber warehouse, compressor houses. C 10 to 20 Limited Inactive storage, stairway B 5 to 10 Seeing Task Typical Type of Work Difficult NOTE: For other industrial footcandle levels such as petrochemical, refer to the Illuminating Engineering Society’s Lighting Handbook (Application Volume) for more information. US: 1-866-764-5454 STIBOINFO((CRH:66008com:L:665)) CH0 0 0 L - 3 CAN: 1-800-265-0502 If the area is non-hazardous in nature, the selection of the proper luminaire and lamp is less restrictive and should be based on general operational and environmental conditions. D) Maintenance Considerations In order to insure optimum performance of the lighting system at a reasonable cost, some of the following related factors must be introduced into the selection process: ɀ Atmospheric Conditions: Luminaires for use in extremely wet locations should be enclosed and gasketed. Luminaires for use in extremely dirty locations should provide a minimum of light depreciation under the anticipated maintenance schedule (i.e., reflector with open top and bottom should be used where maintenance is infrequent). Luminaires for use in extremely corrosive atmospheres should have protection for the optical system and have finishes to withstand the particular corrosive agent (i.e., epoxy power finish; enclosed Alzak reflector; Krydon TM fiberglass reinforced polyester reflector). ɀ Accessibility: Since it may be necessary to locate luminaires in inaccessible areas, the luminaire and lamp selected should minimize need for maintenance and maximize ease of maintenance when required (i.e., high bay open reflector with mercury lamp). ɀ Area Usage: The selection of the proper lamp/luminaire combination will depend greatly on the required burning hours per year. The anticipated usage should be a major factor in lamp selection. † Values recommended are average maintained footcandles at 30⍯ above floor (work plane). Copyright© 2006 Cooper Crouse-Hinds 665 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0666-2 Name: L-666 L 100: DATE: JAN 19 2006 Time: 5:41:49 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Industrial Lighting Products 2 Select Type of Lamp After identification of the factors discussed in Step 1, the following guide can be used in selecting the proper lamp: A) Illumination Level High (30FC or more): high intensity discharge (H.I.D.) lamps are generally the most economic choice. ɀ Exception: where luminaires must be placed within an operator’s normal visual span, a low brightness light source such as fluorescent should be used. Low (less than 30FC): all light sources can be considered. Selection of best lamp is usually based on other factors. ɀ Exception: at medium to high mounting, high intensity discharge is generally best. B) National Electrical Code® Hazardous locations – all light sources can be considered. ɀ Exception: Article 500 of the National Electrical Code classifies the various categories of hazardous locations and provides general rules for the application of luminaires in these areas. (See Step 3 of Selection Guide.) ɀ Exception: where process must be shut down for relamping, high intensity discharge is best due to long lamp life. Non-hazardous locations – all light sources. C) Accessibility High intensity discharge lamps should be used where luminaires are relatively inaccessible because of long life and the need for infrequent relamping. D) Area Usage (Burning Hours) At more than 2,000 burning hours per year, high intensity discharge and fluorescent lamps generally yield the lowest system cost. At less than 2,000 hours per year, incandescent may be the best system depending on the size of the area, mounting height and illumination level required. E) Other Considerations ɀ Energy cost: where energy cost is high, high intensity discharge lamps generally prove most economical. H.I.D. lamps produce more lumens per watt of electricity than other lamp types. ɀ Safety: due to warmup and restart characteristics of high intensity discharge lamps, auxiliary or emergency lighting should be used in critical areas. Continued 666 STIBOINFO((CRH:66008com:L:666)) CH0 0 0 L - 4 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0667-3 Name: L-667 100: DATE: JAN 19 2006 Time: 5:41:50 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Industrial Lighting Products 2 L (continued) Select Type of Lamp The following table of lamp characteristics provides guidelines for choosing the best lamp. If the decision is not obvious, contact your Cooper Crouse-Hinds representative for a computer analysis of the option desired. Table II/Lamp Characteristics Lamp Advantages Disadvantages 1. Induction Exceptionally long life – 100,000 hours. Instant illumination upon start-up or warm restart. Crisp, white light >80 color rending index. Low operating cost. Initial cost is higher than HID type luminaires. 2. High Pressure Sodium Good beam control. Long lamp life (24,000 hrs). Highest lamp output (lumens per watt). Low operating cost. Shortest restart time of H.I.D. lamps (instant with optional instant restrike). High initial cost. Requires warmup period. 3. Metal Halide Pulse Start Improved lamp life (15,000- 30,000 hrs). Increased lumen output over standard metal halide (25 to 50%). Better lumen maintenance (80%). Superior cold starting -40°C. Improved color stability. Color shift reduced by two-thirds. Improved lamp-tolamp color consistency. Warm up time 2 minutes. Restrike time 3-4 minutes. High initial cost. Requires warmup period. Does not restart immediately after power outage. 4. Metal Halide Moderately long lamp life (7500 + hrs). High light output (lumens per watt). Makes colors look close to natural. Low operating cost. High initial cost. Requires warmup period. Does not restart immediately after power outage. 5. Mercury Long lamp life (24,000 hrs). High light output per watt. Low operating cost. High initial cost. Requires warmup period. Does not restart immediately after power outage. 6. Fluorescent Long lamp life (7500-24,000 hrs). High light output per watt. Low operating cost. Low brightness. Cool operation. High initial cost. Poor light control. Output may vary with ambient temperature. 7. Incandescent Low initial cost. Good color rendition. Good light control. Instant restart. Low light output (lumens per watt), short lamp life (500-2000 hrs). High operating cost. US: 1-866-764-5454 STIBOINFO((CRH:66008com:L:667)) CH0 0 0 L - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 667 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0668-7 Name: L-668 L 100: DATE: JAN 19 2006 Time: 5:41:50 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Industrial Lighting Products 3 Select Type of Luminaire Choice of Reflector The following list gives broad guidelines for selection of the proper reflectors. Mounting Height Above Floor Reflector Up to 19 ′ Dome 20′ or more High bay Where low footcandle levels will be provided, reflectors may be used at higher mounting heights than shown; where high footcandle levels will be provided, reflectors may be used at lower mounting heights than shown in the table. Quick Selector (Environment—Product) Opposite the industrial environments listed below are the luminaires designed and approved to meet the requirements unique to each environment. Where different types of light sources might be used, a choice is given. Environment Corrosive Non Metallic Enclosed & Gasketed Explosive Vapors (Class I, Div. 1) Explosionproof Combustible Dusts (Class II, Div. 1) Dustignition-proof Moisture, Non-Combustible Dusts, or Potential for Hazardous Vapors Enclosed & Gasketed Class I, Div. 2 Non-Hazardous 668 STIBOINFO((CRH:66008com:L:668)) CH0 0 0 L - 6 Enclosed & Gasketed US: 1-866-764-5454 Type NDA N2MV N2MVF N2MVFB NFW N2LPS EV, EVI EVLP, EVM Hazard ȿGard® EVF, EVFDR EVFT EVLPF RCDE/RCDER ELPS EVLPFB EV EV DMV Champ® N2MV Champ® DMVIG, VMVIG DMVF, N2MVF EVM Hazard ȿGard® FVN FVS DMVFB, N2MVFB Vaporgard TM CPMV Champ® NDA LMV Champ® DMV Champ® VMV Champ® N2MV Champ® FVN DMVF, N2MVF VF FVS FMV Champ® SSFMV Voyager N2LPS DMVFB, N2MVFB NFL CAN: 1-800-265-0502 Description Cat. Sect. General—Incandescent General—H.I.D. General—Fluorescent Emergency—Fluorescent General—Fluorescent Emergency—Halogen General—Incandescent General—H.I.D. General—Fluorescent General—Fluorescent General—Fluorescent Flood—Incandescent Emergency—Halogen Emergency—Fluorescent Strobe—Incandescent General—Incandescent General—H.I.D. General—H.I.D. General—Induction General—Fluorescent General—H.I.D. General—Fluorescent General—Fluorescent Emergency—Fluorescent General—Incandescent General—H.I.D/Fluorescent General—Incandescent General—H.I.D. General—H.I.D. General—H.I.D. General—H.I.D. General—Fluorescent General—Fluorescent General—Fluorescent General—Fluorescent Flood—H.I.D. Flood—H.I.D. Emergency—Halogen Emergency—Fluorescent General—Fluorescent 1L 3L 6L 10L 6L 10L 2L 4L 6L 6L 6L 7L & 9L 10L 10L 11L 691 721 809 923 809 923 709 779 809 809 809 865 & 913 923 923 939 2L 3L 3L 5L 6L 4L 6L 6L 10L 1L 3L & 6L 1L 3L 3L 3L 3L 6L 6L 6L 6L 7L 7L 10L 10L 6L 709 721 721 801 809 779 809 809 923 691 721 & 809 691 721 721 721 721 809 809 809 809 865 865 923 923 809 Copyright© 2006 Cooper Crouse-Hinds Pg. # Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0669-2 Name: L-669 DATE: JAN 19 2006 Time: 5:41:51 PM Operator: JB TCP: 15001 Typedriver Name: TS name csm no.: 100 H.I.D. Medium Base Series - LMV, EVLP 1 Lamps Used With Cooper Crouse-Hinds Luminaires LAMP WATTS COLOR: CMYK ANSI Ballast L MANUFACTURER GE Osram/ Sylvania Phillips S76 S68 S62 S54 S55 LU35/MED LU50/MED LU70/MED LU100/MED LU150/MED LU35/MED LU50/MED LU70/MED LU100/MED LU150/MED C35S76/M C50S68/M C70S62/M C100S54/M C150S55/M M98 M90 M57 MXR70/U/MED MXR100/U/MED MVR175/U/MED MP70/U/MED MP100/U/MED M175/U/MED MHC70/U/M/3K MHC100/U/M/3K MH175/U/M MXR150/U/MED MXR175/VBU/MED/PA MP150/U/MED Venture High Pressure Sodium 35 50 70 100 150 Metal Halide 70 100 175 MH70W/U MH100W/U Pulse Start Metal Halide 150 175 M102 M137 US: 1-866-764-5454 STIBOINFO((CRH:66008com:L:669)) CH0 0 0 L - 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds MH150W/U/PS MS175W/BU/MED/PS 669 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0670-2 Name: L-670 L LAMP WATTS DATE: JAN 19 2006 Time: 5:41:52 PM Operator: JB TCP: 15001 Typedriver Name: TS name csm no.: 100 H.I.D. Medium Base Series - LMV, EVLP 1 Lamps Used With Cooper Crouse-Hinds Luminaires ANSI Ballast COLOR: CMYK MANUFACTURER MANUFACTURER Lumens/Life (hrs) GE O/S Ph S76 S68 S62 S54 S55 2250/16K 4000/24K 6400/24K 9500/24K 16000/24K 2250/16K 4000/24K 6300/24K 9500/24K 15800/24K 2250/24K 4000/24K 6300/24K 9500/24K 16000/24K M98 M90 M57 5500/12K 9000/15K 13600/10K 5200/15K 8500/15K 14400/10K 6200/10K 9300/12.5K 13500/10K 12500/15K 17700/15K 13300/15K Bulb Venture GE O/S PH B17 B17 B17 B17 B17 E17 E17 E17 E17 E17 ED17 ED17 ED17 ED17 ED17 5600/15K 9000/15K BD17 BD17 BD17 E17 E17 ED17 ED17 ED17 ED17 14000/15K 17500/15K BD17 BD17 E17 E17 Venture High Pressure Sodium 35 50 70 100 150 Metal Halide 70 100 175 ED17 ED17 Pulse Start Metal Halide 150 175 670 STIBOINFO((CRH:66008com:L:670)) CH0 0 0 L - 0 M102 M137 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds ED17 ED17 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0671-3 Name: L-671 DATE: JAN 19 2006 Time: 5:41:52 PM Operator: JB TCP: 15001 Typedriver Name: TS name csm no.: 100 H.I.D. Mogul Base Series - DMV, VMV, CPMV, FMV, F2MV, EVLP 0, FZD Lamps Used With Cooper Crouse-Hinds Luminaires LAMP WATTS COLOR: CMYK ANSI Ballast L MANUFACTURER GE Osram/ Sylvania Phillips Venture High Pressure Sodium 50 70 100 150 150 (100V) S68 S62 S54 S55 S56 LU50 LU70 LU100 LU150/55 LU150/100 LU50 LU70 LU100 LU150/55 LU150/100 C50S68 C70S62 C100S54 C150S55 C150S56 200 250 310 400 1000 S66 S50 S67 S51 S52 LU200 LU250 LU310 LU400 LU1000 LU200 LU250 LU310 LU400 LU1000 C200S66 C250S50 C310S67 C400S51 C1000S52 Metal Halide 70 100 175 250 400 400 1000 1500 M98 M90 M57 M58 M59 M59 M47 M48 MH70W/U/ED28 MH100W/U/ED28 MVR175/U MVR250/U MVR400/U MVR400/U/ED28 MVR1000/U MVR1500/HBD Pulse Start Metal Halide 150 175 200 250 320 350 400 1000 M102 M137 M136 M138 M138 M132 M131 M131 M135 M135 M135 M135 M141 M175/U M250U M400/U M400/U/BT-28 M1000/U M1500/BD MH175/U MH250/U MH400/U MH400/U/ED28 MH1000/U MH1500/BD (Base up+–15%) (Base up+–15%) MXR175/VBU/PA MS175/BU/PS MXR250/VBU/PA MS250/BU/PS MXR320/VBU/PA MS320/PS/BU-ONLY MS320W/BU/PS MXR400/VBU/PA MS400/PS/BU-ONLY MS400/BU/PS HR100A38 HR175A39 HR250A37 HR400A33 HR1000A36 H38HT-100 H39KB-175 H37KB-250 H33CD-400 H36GV-1000 H38HT-100 H39KB-175 H37KB-250 H33CD-400 H36GV-1000 HQI-DE 70/WDX CDM70/TD/830 MH150W/U/ED28/PS MS175W/BU/PS MH200W/U/PS MH250W/HBU/PS MH250W/HBD/PS MH320W/U/ED28/PS MH350W/U/PS MH350W/U/ED28/PS MH400W/HBU/PS MH400W/HBD/PS MH400W/HBU/ED28/PS MH400W/HBD/ED28/PS Mercury Vapor 100 175 250 400 1000 H38 H39 H37 H33 H36 HID Double Contact Metal Halide for EVP Series 70W CMH70/TD/830/R7S US: 1-866-764-5454 STIBOINFO((CRH:66008com:L:671)) CH0 0 0 L - 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 671 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0672-3 Name: L-672 Time: 5:41:53 PM Operator: JB ANSI Ballast COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 H.I.D. Mogul Base Series - DMV, VMV, CPMV, FMV, F2MV, EVM, EVLP 0, FZD Lamps Used With Cooper Crouse-Hinds Luminaires L LAMP WATTS DATE: JAN 19 2006 MANUFACTURER MANUFACTURER Lumens/Life (hrs) GE O/S Ph Bulb Venture GE O/S PH Venture High Pressure Sodium 50 70 100 150 150 (100V) S68 S62 S54 S55 S56 4000/24K 6400/24K 9500/24K 16000/24K 15000/24K 4000/24K 6300/24K 9500/24K 16000/24K 15700/24K 4000/24K 6300/24K 9500/24K 16000/24K 16000/24K ED231/2 ED231/2 ED231/2 ED231/2 ED28 ET231/2 ET231/2 ET231/2 ET231/2 BT28 ED231/2 ED231/2 ED231/2 ED231/2 ED28 200 250 310 400 1000 S66 S50 S67 S51 S52 22000/24K 28000/24K 37000/24K 51000/24K 140000/24K 22000/24K 29000/24K 37000/24K 50000/24K 130000/24K 22000/24K 285000/24K 37000/24K 50000/24K 140000/24K ED18 ED18 ED18 ED18 E25 ET18 ET18 ET18 ET18 E25 ED18 ED18 ED18 ED18 E25 Metal Halide 70 100 175 250 400 400 1000 1500 M98 M90 M57 M58 M59 M59 M47 M48 5600/15K 9000/15K 13600/10K 20800/10K 36000/20K 36000/20K 105000/12K 155000/3K 14400/10K 22000/10K 36000/20K 36000/20K 110000/15K 155000/3K 13500/10K 20500/20K 36000/20K 36000/20K 110000/12K 165000/3K ED28 ED28 ED28 ED28 ED37 ED28 BT56 BT56 BT28 BT28 BT37 BT28 BT56 BT56 ED28 ED28 ED37 ED28 BT56 BT56 Pulse Start Metal Halide 150 175 200 250 320 350 400 1000 M102 M137 M136 M138 M138 M132 M131 M131 M135 M135 M135 M135 M141 17200/15K 16000/15K 23000/15K 23800/15K 31000/15K 32000/20K 44000/20K 41000/20K 44000/20K 14000/15K 17500/15K 21000/15K 25000/15K 25000/15K 33000/20K 37000/20K 37000/20K 44000/20K 44000/20K ED231/2 ED28 ED28 ED28 ED28 BT28 ED28 ED37 BT37 ED37 ED231/2 ED28 ED28 ED37 BT56 ET231/2 BT28 BT28 BT37 BT56 ED231/2 ED28 ED28 ED37 BT56 44000/20K Mercury Vapor 100 175 250 400 1000 672 STIBOINFO((CRH:66008com:L:672)) CH0 0 0 L - 0 H38 H39 H37 H33 H36 3850/24K 7850/24K 11000/24K 21000/24K 57000/24K 4000/24K 7700/24K 11600/24K 20500/24K 55200/24K US: 1-866-764-5454 4100/24K 7900/24K 12100/24K 21000/24K 57500/24K CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds ED28 ED28 ED28 ED28 ED28 ED28 ED37 ED28 ED37 ED37 ED28 ED28 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0673-3 Name: L-673 DATE: JAN 19 2006 Time: 5:43:00 PM Operator: JB BASE TCP: 15001 Typedriver Name: TS name csm no.: 100 Fluorescent Lamps Lamps Used With Cooper Crouse-Hinds Luminaires LAMP WATTS COLOR: CMYK LUMINAIRE SERIES L MANUFACTURER GE Osram/ Sylvania Phillips F5BX/SPX41/840 F7BX/SPX35/835 F9BX/SPX35/835 F13DBX23T4/SPX35 CF5DS/841 CF7DS/835 CF9DS/835 CF13DD/835 PL-S5W/27 PL-S7W/35 PL-S9W/35 PL-C13W/35/USA F26TBX/SPX35/A/4P CF26DT/E/IN/835 PL-T26W/35/4P/ALTO F32TBX/SPX35/A/4P CF32DT/E/IN/835 PL-T32W/35/4P/ALTO F42QBX/SPX35/A/4P CF42DT/E/IN/835 PL-T42W/35/4P/ALTO F39/36/BX/SPX35 F40/30BX/SPX35 FT36DL/835 FT40DL/835/RS PL-L36W/35 PL-L40W/35/RS F32T8/SP35 F032/735 F32T8/TL735/ALTO F40CW/RS/WM F40CW/SS F40CW/RS/EW/ALTO F48T12/CW/HO F48T12/CW/HO F48T12/CW/HO F48T12/CW/1500 F48T12/CW/VHO F48T12/CW/VHO Compact 5W-T4 7W-T4 9W-T4 13W-T4 G23 G23 G23 GX23-2 26W-T4 GX24q-3 32W-T4 GX24q-3 42W-T4 GX24q-4 VF VF VF DMVF (Disc) DMVF, N2MVF, CPMVF, EVLPF DMVF, N2MVF, CPMVF, EVLPF DMVF, N2MVF, CPMVF, EVLPF Long Twin Tube 70 40 2G11 2G11 EVFT NFL, FVS Linear 32W-T8 40(34)W-T12 60W (800ma)-T12 HIGH OUTPUT 110W (1500ma)-T12 VERY HIGH OUTPUT Medium Bipin Medium Bipin Recessed Double Contact Recessed Double Contact NFL, FVN, EVF, EVFDR NFL, FVN, EVF, EVFDR FVN, EVF, EVFDR EVF, EVFDR US: 1-866-764-5454 STIBOINFO((CRH:66008com:L:673)) CH0 0 0 L - 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 673 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0674-3 Name: L-674 DATE: JAN 19 2006 Time: 5:43:04 PM Operator: JB Lamps Used With Cooper Crouse-Hinds Luminaires L LAMP WATTS BASE COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Fluorescent Lamps LUMINAIRE SERIES MANUFACTURER GE Lumens/Life (Hrs) Osram/Sylvania Phillips 250/10K 400/10K 600/10K 810/10K 230/10K 400/10K 580/10K 780/10K 250/10K 400/10K 600/10K 860/10K 1800/10K 1800/10K 1800/10K 2200/10K 2400/10K 2400/10K 3200/10K 3200/10K 3200/10K 2850/12K 3150/20K 2900/12K 3150/20K 2900/12K 3150/20K Compact 5W-T4 7W-T4 9W-T4 13W-T4 G23 G23 G23 GX23-2 26W-T4 GX24q-3 32W-T4 GX24q-3 42W-T4 GX24q-4 VF VF VF DMVF (Disc) DMVF, N2MVF, CPMVF, EVLPF DMVF, N2MVF, CPMVF, EVLPF DMVF, N2MVF, CPMVF, EVLPF Long Twin Tube 70 40 2G11 2G11 EVFT NFL, FVS Linear 32W-T8 40(34)W-T12 60W (800ma)-T12 HIGH OUTPUT 110W (1500ma)-T12 VERY HIGH OUTPUT 674 STIBOINFO((CRH:66008com:L:674)) CH0 0 0 L - 0 Medium Bipin Medium Bipin Recessed Double Contact Recessed Double Contact NFL, FVN, EVF, EVFDR NFL, FVN, EVF, EVFDR FVN, EVF, EVFDR 2850/20K 2800/20K 2850/20K 2650/20K 2700/20K 2650/20K 4050/12K 4050/12K 4050/12K EVF, EVFDR 6200/10K 6600/10K 7050/12K US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0675-2 Name: L-675 100: DATE: JAN 19 2006 Time: 5:43:04 PM Operator: JB EXLD 50W PAR20 EVTL 52W A19 58W A19 ELG ELG 60W T10 65W BR30 75W ER30 100W A19 EXL EVO2376 EVO2376 EV 40 Series V160, EV160, EVH, EV 15 Series VS Suffix QTZ Vaporgard 150W EV 10 Series EV 20 Series V Series RCDE6 Vaporgard 200W EV 10 Series Vaporgard 200W EV 15 Series EV 15 Series EV 20 Series EV 30 Series 100W A23 100W D.C. Bay 150W A21 150W A23 150W PAR38 200W A23 200W A25 200W PS25 200W PS30 300W PS25 300W PS30 300W R40 300W PS35 500W PS40 500W PAR64 Vapourgard 300W NDA EV 15 Series Vaporgard 300W EV 20 Series EV 15 Series RCDE6 EV 30 Series EV 30 Series RCDE10 US: 1-866-764-5454 STIBOINFO((CRH:66008com:L:675)) CH0 0 0 L - 0 Typedriver Name: TS name csm no.: 100 L LUMINAIRE SERIES 25W T10 100W A21 TCP: 15001 Incandescent & Quartz (Halogen) Lamps Lamps Used With Cooper Crouse-Hinds Luminaires MAX WATTS AND BULB TYPE COLOR: CMYK MANUFACTURER GE Osram/ Sylvania Phillips 25T10 50PAR20/H/SP10 50PAR20/H/FL25 25T10 50PAR20/CAP/NSP 50PAR20/CAP/NFL 25T10 50PAR20/HAL/NSP9 50PAR20/HAL/NFL30 60A52WMP/98 60A52/SS/XL 58A19/62 60A-52A/99/EW 60T10 75R30/SP/65WM 75ER30 100A (IF) 60T10 65BR30/SP 75ER30 100A (IF) 60T10 65BR30/SP20 75ER30 100A (IF) 100A21 (IF) 100A21 (IF) 100A21 (IF) 100A23 120V Q100CL/DC 100A23 100Q/CL/DC 100A23 100Q/CL/DC 150A (IF) 150A (IF) 150A (IF) 150A23 (IF) 150PAR/FL 150A23/CL 150PAR38/2FL 200A23 (IF) 200A (IF) 200A25/35 200PS25/99XL 200 130V 200PS/CL 130V 300M 200 130V 300M 300M/99 (130v) 300M/CL 300M/PS30 300R/FL 300 500PS40 500PAR64/MFL 300R40/FL 300/CL 300BR/FL 300 500PS40 500PAR64/MFL CAN: 1-800-265-0502 500PAR64/MFL Copyright© 2006 Cooper Crouse-Hinds 675 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0676-2 Name: L-676 DATE: JAN 19 2006 Time: 5:43:05 PM Operator: JB MAX WATTS AND BULB TYPE 25W T10 50W PAR20 52W A19 58W A19 60W T10 65W BR30 75W ER30 100W A19 100W A21 100W A23 100W D.C. Bay 150W A21 150W A23 150W PAR38 200W A23 200W A25 200W PS25 200W PS30 300W PS25 300W PS30 300W R40 300W PS35 500W PS40 500W PAR64 676 STIBOINFO((CRH:66008com:L:676)) LUMINAIRE SERIES EXLD EVTL ELG ELG EXL EVO2376 EVO2376 EV 40 Series V160, EV160, EVH, EV 15 Series VS Suffix QTZ Vaporgard 150W EV 10 Series EV 20 Series V Series RCDE6 Vaporgard 200W EV 10 Series Vaporgard 200W Ev 15 Series EV 15 Series EV 20 Series EV 30 Series Vapourgard 300W NDA EV 15 Series Vaporgard 300W EV 20 Series EV292 Series RCDE6 EV 30 Series EV 30 Series RCDE10 US: 1-866-764-5454 COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Incandescent & Quartz (Halogen) Lamps Lamps Used With Cooper Crouse-Hinds Luminaires L CH0 0 0 L - 0 100: MANUFACTURER GE Lumens O/S 248 570 570 670 630 740 775 850 1710 232 530 530 650 630 630 640 750 1750 1710 MANUFACTURER Ph GE Life-Hours O/S PH 260 550 550 564 630 745 1650 1000 2500 2500 2500 3000 1000 2000 2000 750 1000 2500 2500 2500 3000 1000 2000 2000 750 1000 2000 2000 4250 3000 1000 2000 2000 750 1690 1680 750 750 750 1600 1600 1600 1730 1600 750 2000 750 2000 750 2000 2850 2780 2850 750 750 750 1660 2810 1660 2475 1660 2000 750 2000 1275 2000 3930 3800 750 750 2720 2720 2720 3500 3500 3500 3000 3000 3000 2500 2500 2500 2725 2665 2825 1950 1875 2120 6280 750 750 750 6200 3935 5870 6100 6800 7500 7500 3700 5820 9900 6500 3030 5700 10100 np 5700 10100 2000 1000 1000 2000 2000 1000 1000 2000 2000 1000 1000 2000 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0677-2 Name: L-677 DATE: JAN 19 2006 Time: 5:43:06 PM Operator: JB TCP: 15001 Typedriver Name: TS name csm no.: 100 High Pressure Sodium Data Ballasts Used With Cooper Crouse-Hinds Luminaires L Watts ANSI Code Volts Type R/HX/CWA Starting Current Operating Current Input Watts 35 S76 120 R-HPF 0.8 0.4 46 CHRBS 035 /120 50 S68 120 120/277 220/240-50 Hz R-HPF HX-HPF HX-HPF 1.0 0.7/0.3 0.3/0.3 0.6 0.6/0.3 0.6/0.6 62 66 66 CHRBS 050 CHRBS 050 CHRBS 050 /120 /DT /220 50 S62 120 120/208/240/277 120/277/347 220 420 220/240-50Hz R-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF 0.9 0.8/0.5/0.4/0.4 .8/.4/.3 0.4 0.2 .5/.4 0.8 0.8/0.5/0.4/0.4 0.8/0.4/0.3 0.4 0.2 .5/.4 86 91 93 91 93 94 CHRBS CHRBS CHRBS CHRBS CHRBS CHRBS 070 070 070 070 070 070 /120 /MT /TT /220 /480 /220 50 S54 120 120/208/240/277 120/277/347 220 480 220/240-50 Hz R-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF 1.5 1.3/0.8/0.7/0.6 1.3/0.6/0.5 0.7 0.4 0.5/0.5 1.1 1.2/0.7/0.6/0.5 1.2/0.5/0.4 0.6 0.3 0.7/0.6 115 130 130 130 130 130 CHRBS CHRBS CHRBS CHRBS CHRBS CHRBS 100 100 100 100 100 100 /120 /MT /TT /220 /480 /220 50 150 (55v) S55 120 120/208/240/277 120/277/347 220 480 220/240-50 Hz R-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF 2.3 2.0/1.2/1.0/0.9 2.0/0.9/0.5 1.1 0.5 0.9/0.8 1.5 1.7/1.0/0.8/0.7 1.7/0.7/0.6 0.9 0.4 0.9/0.8 170 188 188 188 188 188 CHRBS CHRBS CHRBS CHRBS CHRBS CHRBS 150 150 150 150 150 150 /120 /MT /TT /220 /480 /220 50 150 (100v) S56 120/208/240/277 480 220/240-50 Hz CWA CWA R-PFC 1.2/0.7/0.6/.05 0.3 0.9/1.0 1.8/1.0/0.9/0.8 0.4 0.9/0.8 188 188 175 CHRBS 150 CHRBS 150 CHRBS 150 200 S66 12-/208/240/277 480 CWA CWA 1.4/0.8/0.7/0.6 0.4 2.4/1.4/1.2/1.0 0.6 250 250 CHRBS 200 /MT CHRBS /200 /480 S50 120 120/208/240/277 120/277/347 220 480 230-50 Hz CWA CWA CWA CWA CWA CWA 1.7 1.7/1.0/0.8/0.7 1.7/0.7/0.6 0.9 0.4 1.0 2.5 2.5/1.5/1.3/1.1 2.7/1.2/0.9 1.5 0.7 1.4 295 295 295 295 310 300 CHRBS CHRBS CHRBS CHRBS CHRBS CHRBS 250 250 250 250 250 250 /120 /MT /TT /220 /480 /220 50 S51 120 120/208/240/277 120/277/347 220 480 230-50 Hz CWA CWA CWA CWA CWA CWA 3.3 3.3/1.8/1.5/1.4 3.3/1.4/1.0 1.6 0.8 1.9 3.8 3.8/2.2/1.9/1.7 3.8/1.7/1.3 2.1 1.0 2.0 457 464 464 457 464 465 CHRBS CHRBS CHRBS CHRBS CHRBS CHRBS 400 400 400 400 400 400 /120 /MT /TT /220 /480 /220 50 S52 120/208/240/277 120/277/347 220 480 220/240-50 Hz CWA CWA CWA CWA CWA 6.4/3.8/3.2/2.8 6.4/2.8/2.2 3.6 1.6 6.0/5.6 9.5/5.5/4.8/4.2 9.5/4.2/3.3 5.0 2.3 5.2/4.8 1100 1100 1100 1100 1100 CHRBS CHRBS CHRBS CHRBS CHRBS 1000 1000 1000 1000 1000 /MT /TT /220 /480 /220 50 70 100 250 400 1000 US: 1-866-764-5454 STIBOINFO((CRH:66008com:L:677)) CH0 0 0 L - 0 COLOR: CMYK CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Kit Cat No. /MT CE /480 CE /220 50 CE 677 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 100: JOB: CRMAIN06-0678-3 Name: L-678 DATE: JAN 19 2006 Time: 5:43:06 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Pulse Start Metal Halide Data Ballasts Used With Cooper Crouse-Hinds Luminaires L Watts ANSI Code Volts Type R/HX/CWA Starting Current Operating Current Input Watts 150 M102 120/208/240/277 120/277/347 HX-HPF HX-HPF 1.8/1.3/0.9/0.8 1.8/0.8/0.7 1.6/1.0/0.8/0.7 1.6/0.7/0.6 185 185 CHRBM 150 CHRBM 150 /MT /TT S828 S828 175 M137 120/208/240/277 120/277/347 Super CWA Super CWA 1.0/0.6/0.5/0.4 0.8/0.4/0.3 1.8/1.1/0.9/0.8 1.9/0.8/0.7 208 208 CHRBM 175 CHRBM 175 /MT /TT S828 S828 200 M136 120/208/240/277 120/277/347 480 Super CWA Super CWA Super CWA 0.80.4/0.4/0.3 0.7/0.3/0.3 0.2 2.0/1.2/1.0/0.9 2.1/0.9/0.7 0.5 232 232 232 CHRBM 200 CHRBM 200 CHRBM 200 /MT /TT /480 S828 S828 S828 250 M138 120/208/240/277 120/277/347 Super CWA Super CWA 2.3/1.3/1.2/1.0 2.0/0.9/0.8 2.5/1.5/1.3/1.1 2.5/1.1/0.9 288 290 CHRBM 250 CHRBM 250 /MT /TT S828 S828 M132 120/208/240/277 120/277347 220 480 230/50 Super CWA Super CWA Super CWA Super CWA Super CWA 1.8/1.1/0.9/0.8 2.2/1.0/0.7 1.4 0.5 1.1 3.3/1.9/1.7/1.4 3.3/1.4/1.1 1.7 0.8 1.6 368 368 365 368 365 CHRBM CHRBM CHRBM CHRBM CHRBM 250 250 250 250 250 /MT /TT /220 /480 /220 50 S828 S828 S828 S828 S828 M135 120/208/240/277 120/277/347 480 230/50 Super CWA Super CWA Super CWA Super CWA 2.9/1.7/1.5/1.3 3.2/1.4/1.1 0.8 2.0 3.8/2.2/1.9/1.7 3.8/1.7/1.4 1.0 2.1 452 450 452 454 CHRBM CHRBM CHRBM CHRBM 400 400 400 400 /MT /TT /480 /220 50 S828 S828 S828 S828 M141 120/208/240/277 347 480 220/240-50 Hz Super CWA Super CWA Super CWA CWA 7.8/4.0/3.7/3.2 2.3 1.7 4.5/4.1 9.0/5.2/4.5/3.9 3.2 2.4 5.0/4.5 1080 1075 1075 1090 CHRBM CHRBM CHRBM CHRBM 1000 1000 1000 1000 /MT /347 /480 /220 50 S828 S828 S828 S828 320 400 1000 678 STIBOINFO((CRH:66008com:L:678)) CH0 0 0 L - 0 98: US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Kit Cat No. Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0679-2 Name: L-679 DATE: JAN 19 2006 Time: 5:43:07 PM Operator: JB 70 100 175 250 400 1000 1500 STIBOINFO((CRH:66008com:L:679)) Typedriver Name: TS name csm no.: 100 L ANSI Code Volts Type R/HX/CWA Starting Current Operating Current Input Watts M98 120/208/240/277 120/277/347 220 220/240-50 Hz HX-HPF HX-HPE HX-HPF HX-HPF 0.6/0.3/0.3/0.3 0.6/0.2/0.2 0.4 0.7/0.6 0.8/0.5/0.4/0.4 0.8/0.4/0.3 0.5 0.5/0.4 88 88 94 95 CHRBM CHRBM CHRBM CHRBM 070 070 070 070 /MT /TT /220 /220 50 M90 120/208/240/277 120/277/347 220 480 220/240-50 Hz HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF 1.2/0.8/0.7/0.6 1.2/0.5/0.4 0.9 0.3 0.7/0.7 1.2/0.7/0.6/0.5 1.2/0.5/0.4 0.6 0.3 0.7/0.6 129 129 129 132 129 CHRBM CHRBM CHRBM CHRBM CHRBM 100 100 100 100 100 /MT /TT /220 /480 /220 50 M57 120 120/208/240/277 120/277/347 220 480 230/50 CWA CWA CWA CWA CWA CWA 1.3 1.3/0.8/0.7/0.6 1.3/0.6/0.5 0.6 0.4 0.8 1.8 1.8/1.1/0.9/0.8 1.8/0.8/0.7 1.0 0.5 1.1 210 210 210 210 210 210 CHRBM CHRBM CHRBM CHRBM CHRBM CHRBM 175 175 175 175 175 175 /120 /MT /TT /220 /480 /220 50 M58 120 120/208/240/277 120/277/347 220 480 230/50 CWA CWA CWA CWA CWA CWA 1.0 1.0/0.6/0.5/0.5 2.2/1.0/0.8 1.4 0.6 1.0 2.6 2.6/1.5/1.3/1.1 2.5/1.1/0.9 1.5 0.6 1.3 294 294 295 295 295 290 CHRBM CHRBM CHRBM CHRBM CHRBM CHRBM 250 250 250 250 250 250 /120 /MT /TT /220 /480 /220 50 M59 120 120/208/240/277 120/277/347 220 480 230/50 CWA CWA CWA CWA CWA CWA 3.0 3.5/2.0/1.8/1.5 3.5/1.5/1.2 1.9 0.9 1.4 4.0 4.0/2.2/2.0/1.8 4.0/1.8/1.4 2.2 1.0 2.1 456 458 460 458 462 462 CHRBM CHRBM CHRBM CHRBM CHRBM CHRBM 400 400 400 400 400 400 /120 /MT /TT /220 /480 /220 50 M47 120/208/240/277 120/277/347 220 480 220/240-50 Hz CWA CWA CWA CWA CWA 7.84.0/3.7/3.2 7.8/3.2/2.5 3.9 1.9 4.5/4.1 9.0/5.2/4.5/3.9 9.0/3.9/3.2 4.9 2.3 5.0/4.5 1080 1080 1080 1080 1090 CHRBM CHRBM CHRBM CHRBM CHRBM 1000 /MT 1000 /TT 1000 /220 1000 /480 1000 /220 50 M48 120/208/240/277 120/277347 220 480 220/240-50 Hz CWA CWA CWA CWA CWA 13.4/7.7/6.7/5.7 13.4/5.7/4.6 7.3 3.3 6.9/6.3 13.5/7.8/6.8/5.9 13.5/5.9/4.8 7.4 3.4 7.5/6.9 1605 1615 1605 1625 1605 CHRBM CHRBM CHRBM CHRBM CHRBM 1500 /MT 1500 /TT 1500 /220 1500 /480 1500 /220 50 US: 1-866-764-5454 CH0 0 0 L - 0 TCP: 15001 Metal Halide Data Ballasts Used With Cooper Crouse-Hinds Luminaires Watts COLOR: CMYK CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Kit Cat No. 679 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 100: JOB: CRMAIN06-0680-3 Name: L-680 Watts 100 175 250 400 1000 680 STIBOINFO((CRH:66008com:L:680)) DATE: JAN 19 2006 Time: 5:43:08 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Mercury Vapor Data Ballasts Used With Cooper Crouse-Hinds Luminaires L CH0 0 0 L - 0 98: ANSI Code Volts Type R/HX/CWA Starting Current Operating Current Input Watts H38 120 120/208/240/277 120/277/347 480 220/240-50 Hz CWA CWA CWA CWA CWA 1.1 1.1/0.6/0.5/0.5 1.1/0.5/0.4 0.3 0.7/0.6 1.1 1.1/0.6/0.5/0.5 1.1/0.5/0.3 0.3 0.6/0.5 120 125 125 125 125 CHRBC CHRBC CHRBC CHRBC CHRBC 100 100 100 100 100 /120 /MT /TT /480 /220 50 H39 120 120/208/240/277 120/277347 220 480 230/50 CWA CWA CWA CWA CWA CWA 1.6 1.6/1.0/0.8/0.7 1.3/0.6/0.5 0.6 0.4 0.8 1.9 1.9/1.1/1.0/0.8 1.8/0.8/0.7 1.0 0.4 1.1 205 205 210 210 200 210 CHRBC CHRBC CHRBC CHRBC CHRBC CHRBC 175 175 175 175 175 175 /120 /MT /TT /220 /480 /220 50 H37 120 120/208/240/277 120/277/347 220 480 230/50 CWA CWA CWA CWA CWA CWA 2.5 2.5/1.5/1.3/1.1 2.2/1.0/0.8 1.4 0.6 1.0 2.5 2.5/1.5/1.3/1.1 2.5/1.1/0.9 1.5 0.6 1.3 280 285 295 295 285 290 CHRBC CHRBC CHRBC CHRBC CHRBC CHRBC H33 120/208/240/277 120/277/347 220 480 230/50 CWA CWA CWA CWA CWA 3.2/2.0/1.7/1.7 3.5/1.5/1.2 1.9 1.0 1.4 3.9/2.2/2.0/1.7 4.0/1.8/1.4 2.1 1.0 2.1 454 460 454 454 462 CHRBC CHRBC CHRBC CHRBC CHRBC 400 400 400 400 400 /MT /TT /220 /480 /220 50 H36 120/208/240/277 120/277/347 220 480 220/240-50 Hz CWA CWA CWA CWA CWA 8.0/4.6/4.0/3.5 7.8/3.2/2.5 3.9 1.9 4.5/4.1 9.8/5.6/4.9/4.3 9.0/3.9/3.2 4.9 2.3 5.0/4.5 1080 1080 1080 1080 1090 CHRBC CHRBC CHRBC CHRBC CHRBC 1000 1000 1000 1000 1000 /MT /TT /220 /480 /220 50 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Kit Cat No. 250 250 250 250 250 250 /120 /MT /TT /220 /480 /220 50 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0681-2 Name: L-681 DATE: JAN 19 2006 Time: 5:43:08 PM Operator: JB Ballasts Used With Cooper Crouse-Hinds Luminaires Luminaire Series Lamp Type & Watts COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Fluorescent Data L Lamp Base Lamp No. Qty. Ballast Voltage Starting Operating Amp Input Watts Kit Cat. No. COMPACT VF 9W T4 G23 2 120 0.4 22 CHRBF2C18/120 DMVF, N2MVF, EVLPF 26W T4 26W T4 26W T4 26W T4 26W T4 26W T4 GX24q-3 GX24q-3 GX24q-3 GX24q-3 GX24q-3 GX24q-3 2 2 2 2 2 2 120 220/240 277 347 DC 12V DC 24V 0.5 0.3 0.2 0.2 3.6 1.8 55 55 55 44 43 43 CHRBF4C64/UNV CHRBF4C64/UNV CHRBF4C64/UNV CHRBF4C64/347 CHRBF4C64/12VDC CHRBF4C64/24VDC DMVF, N2MVF, EVLPF 32W T4 32W T4 32W T4 32W T4 32W T4 32W T4 GX24q-3 GX24q-3 GX24q-3 GX24q-3 GX24q-3 GX24q-3 2 2 2 2 2 2 120 220/240 277 347 DC 12V DC 24V 0.6 0.3 0.3 0.2 4.4 2.2 68 68 68 62 60 60 CHRBF4C64/UNV CHRBF4C64/UNV CHRBF4C64/UNV CHRBF4C64/347 CHRBF4C64/12VDC CHRBF4C64/24VDC CPMVF 42W T4 42W T4 42W T4 GX24q-4 GX24q-4 GX24q-4 2 2 2 120 277 347 0.8 0.3 0.3 93 68 80 CHRBF4C84/120 CHRBF4C84/277 CHRBF4C84/347 LONG TWIN TUBE NFL 40W T5 40W T5 40W T5 40W T5 2G11 2G11 2G11 2G11 1 1 1 1 120 277 347 220/240 0.4 0.2 0.1 0.2 42 42 44 41 CHRBFT40/120 CHRBFT40/277 CHRBFT80/347 CHRBFT80/UNV FVS 40W T5 40W T5 40W T5 40W T5 2G11 2G11 2G11 2G11 2 2 2 2 120 277 347 220/240 0.6 0.3 0.2 0.3 76 73 70 74 CHRBFT80/UNV CHRBFT80/UNV CHRBFT80/347 CHRBFT80/UNV EVFT 36/39W 36/39W 36/39W 2G11 2G11 2G11 2 2 2 120 277 220/240 0.6 0.3 0.3 74 74 71 CHRBFT78/120 CHRBFT78/277 CHRBFT78/220 Note: For 3 Lamp luminaires, order one 1 lamp ballast and one 2 lamp, lamp ballast. Add current and watts values For 4 lamp luminaires, order two 2 lamp, lamp ballasts. Double currents and watts values US: 1-866-764-5454 STIBOINFO((CRH:66008com:L:681)) CH0 0 0 L - 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 681 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0682-2 Name: L-682 L 100: DATE: JAN 19 2006 Time: 5:43:09 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Fluorescent Data Ballasts Used With Cooper Crouse-Hinds Luminaires Lamp Base Lamp No. Qty. Ballast Voltage Starting Operating Amp Input Watts Kit Cat. No. NFL, FVN, EVF & EVFDR 32W T8 32W T8 32W T8 32W T8 32W T8 32W T8 32W T8 32W T8 Med Bipin Med Bipin Med Bipin Med Bipin Med Bipin Med Bipin Med Bipin Med Bipin 1 1 1 1 2 2 2 2 120 277 347 220/240 120 277 347 220 0.3 0.2 0.1 0.3 0.5 0.2 0.1 0.4 35 35 32 38 58 58 50 58 CHRBFL64/UNV CHRBFL64/UNV CHRBFL64/347 CHRBFL64/UNV CHRBFL64/UNV CHRBFL64/UNV CHRBFL64/347 CHRBFL64/UNV NFL, FVN, EVF & EVFDR 40(34W)T12 40(34W)T12 40(34W)T12 40(34W)T12 40(34W)T12 40(34W)T12 40(34W)T12 40(34W)T12 Med Bipin Med Bipin Med Bipin Med Bipin Med Bipin Med Bipin Med Bipin Med Bipin 1 1 1 1 2 2 2 2 120 277 347 220 50 120 277 347 220/240 0.4 0.2 0.2 0.2 0.6 0.3 0.2 0.2 46 46 52 51 73 80 62 71 CHRBFL80/120 CHRBFL80/277 CHRBFL40/347 CHRBFL40/220 50 CHRBFL80/120 CHRBFL80/277 CHRBFL80/347 CHRBFL80/220 FVN, EVF & EVFDR 60W (800ma) T12 HO 60W (800ma) T12 HO 60W (800ma) T12 HO 60W (800ma) T12 HO 60W (800ma) T12 HO 60W (800ma) T12 HO Recessed Double Contact Recessed Double Contact Recessed Double Contact Recessed Double Contact Recessed Double Contact Recessed Double Contact 1 1 1 2 2 2 120 277 220 50 120 277 220 50 0.9 0.5 0.7 1.2 0.5 1.0 79 82 140 133 131 224 CHFBFL120/120 CHFBFL120/277 CHFBFL120/220 50 CHFBFL120/120 CHFBFL120/277 CHFBFL120/220 50 EVF & EVFDR 110W (1500ma) T12 VHO 110W (1500ma) T12 VHO 110W (1500ma) T12 VHO 110W (1500ma) T12 VHO Recessed Double Contact Recessed Double Contact Recessed Double Contact Recessed Double Contact 1 1 2 2 120 277 120 277 1.7 0.6 2.2 0.9 130 137 230 241 CHRBFL220/120 CHRBFL220/277 CHRBFL220/120 CHRBFL220/277 Luminaire Series Lamp Type & Watts LINEAR Note: For 3 Lamp Luminaires, order one 1 lamp ballast and one 2 lamp, lamp ballast. Add current and watts values For 4 lamp luminaires, order two 2 lamp, lamp ballasts. Double currents and watts values 682 STIBOINFO((CRH:66008com:L:682)) CH0 0 0 L - 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0683-3 Name: L-683 100: DATE: JAN 19 2006 Time: 5:43:10 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Industrial Lighting Products L 4 Calculate the Number of Luminaires Required For uniform lighting of a specific area, the lumen method is used to calculate the number of luminaires required. This method takes into account not only the direct light from the luminaire, but also that which is reflected from the ceiling, walls and floor. As the calculations will show, the higher the reflectivity of the surfaces, the fewer number of luminaires required. Clean, light-colored surfaces also provide visual comfort. The Coefficient of Utilization as used in these calculations makes allowances for light absorbed by walls and ceiling, and the light absorbed within the luminaire. To obtain the Coefficient of Utilization, the reflection factors of the walls, floors, and ceiling must be estimated. These reflectances should be the minimum values expected just before cleaning or repainting of the surfaces. The reference below gives approximate factors for various surfaces. Reflectance Color Factor White . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80% Light tints of blue-green, cream, blue, buff or gray . . . . . . . . . . . . . . . . . . . . . . . . . . 70% Medium blue-green, yellow, medium buff, or gray . . . . . . . . . . . . . . . . . . . . . . . . . 50% Dark gray, medium blue . . . . . . . . . . . . . . . 30% Dark blue, brown, dark green, and many wood finishes, such as dark oak and mahogany . . . . . . . . . . . . . . . . . . . . . . . . . . . 10% When supplementary lighting (highlighting) or floodlighting is needed, use the point-bypoint method to determine footcandles at a specific point or points on the work plane. This method can also be used with angle reflectors for lighting of irregular rooms or where ceiling use is restricted. Candlepower distribution curves for individual lighting units are shown on the appropriate catalog pages. 4a 4b Determine Cavity Ratios Determine Cavity Reflectances There are three Cavity Ratios that should be determined, as in Figure 1: Ceiling Cavity Ratio Room Cavity Ratio Floor Cavity Ratio Each of these ratios can be found through use of Table IV, page 684. Simply find the appropriate Cavity Depth, whether it is Ceiling Cavity Depth (hCC), Room Cavity Depth (hRC), or Floor Cavity Depth (hFC), and match it with the room length and width to obtain the Cavity Ratio. For example, to determine the Ceiling Cavity Ratio when the Ceiling Cavity Depth (distance from luminaire to ceiling) is 4′, the width of the room 20′ and the length 60′, crossreference to Cavity Depth 4.0, width 20, length 60, and find Ceiling Cavity Ratio of 1.3. If the Room Cavity Depth (distance from luminaire to work plane) is 12′, then the Room Cavity Ratio would be 4.0. Basic Steps in the Lumen Method Effective reflectances of the different room cavities are determined in Table V, page 685, by using the estimated ceiling, wall and floor reflectances together with the corresponding cavity ratios. Using the example in Step 4a, we estimate the wall reflectance at 70% and the ceiling reflectance at 70%. Using the Ceiling Cavity Ratio of 1.3 (also from Step 4a) in Table V, we find the Effective Ceiling Cavity Reflectance is 61%. 4c Determine Coefficient of Utilization The Coefficient of Utilization is determined from the CU table found on the catalog page for the previously selected luminaire/lamp combination. Using our example again, the three required factors for use with the CU table would be: Room Cavity Ratio (from Step 4a). . . . . . . . . . . . . . . . . . . . . . . . . 4.0 Wall Reflectance (from Step 4b) . . . . . . . . . . . . . . . . . . . . . . . 70% Effective Ceiling Cavity Reflectance (from Step 4b) . . . . . . . . . . . . . . . . . . . . . . . 61% In most instances some interpolations will be necessary to obtain the proper Coefficient of Utilization. You will note that the table gives Coefficients of Utilization for a 20% Effective Floor Cavity Reflectance. Use of this factor for all applications will provide reasonable accuracy; however, if more accuracy is desired, refer to the current Illuminating Engineering Society Handbook for an additional detailed step. (Zonal Cavity Method) Step 4a Step 4b Step 4c Step 4d Step 4e Step 4f Determine Cavity Ratios Determine Cavity Reflectances Determine Coefficient of Utilization Determine Light Loss Factor Calculate Lamp Lumens Required Calculate Number of Luminaires Required Figure 1/The three cavities used in the Lumen Method US: 1-866-764-5454 STIBOINFO((CRH:66008com:L:683)) CH0 0 0 L - 7 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 683 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0684-2 Name: L-684 L 100: DATE: JAN 19 2006 Time: 5:43:10 PM Operator: JB COLOR: CMYK TCP: 15001 Industrial Lighting Products Table IV/Cavity Ratios 684 STIBOINFO((CRH:66008com:L:684)) CH0 0 0 L - 8 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0685-2 Name: L-685 100: DATE: JAN 19 2006 Time: 5:43:12 PM Operator: JB COLOR: CMYK TCP: 15001 Industrial Lighting Products Typedriver Name: TS name csm no.: 100 L Table V/Effective Ceiling Reflectance US: 1-866-764-5454 STIBOINFO((CRH:66008com:L:685)) CH0 0 0 L - 9 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 685 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0686-6 Name: L-686 DATE: JAN 19 2006 Time: 5:43:13 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Industrial Lighting Products L 4d 4f Determine Light Loss Factor Calculate Number of Luminaires Required The light loss factor takes into account two things: lamp light output dropoff (lamp lumen depreciation) and dirt accumulation on the luminaire, lamp and reflector. The table below lists suggested total light loss factors according to light source and operating conditions. (Other factors that may affect light loss, such as voltage to luminaire, luminaire ambient temperature (fluorescent) and ballast operating characteristics, should also be considered.) Formula: Typical Lamp Lumens from list below:ɍ ɍ Lamp Induction Watts 55 85 165 Lumens 3500 6000 12000 Life (hours) 100,000 100,000 100,000 Suggested Total Light Loss Factors Operating Conditions Incandescent (inside frosted) 100 150 200 A-23; PS-30, PS-25 300 PS-25; PS-30; PS-35; 500 1750 2880 4010 3710 6360 6110 5820 10850 750 750 750 750 750 750 1000 1000 Mercury Vapor (deluxe white) 100 175 250 400 1000 4200 8600 12100 22500 63000 24000 24000 24000 24000 24000 Metal Halide (clear) 70 100 175 250 400 1000 5600 7800 14000 20500 36000 110000 10000 10000 10000 10000 20000 12000 High Pressure Sodium (clear) 35 50 70 100 150 200 250 400 1000 2250 4000 6400 9500 16000 22000 27500 50000 140000 16000 24000 24000 24000 24000 24000 24000 24000 24000 Linear Fluorescent 32 (T8) 40 (Slimline) 40 (Rapid Start) 60 (800 ma) 110 (1500 ma) 215 (1500 ma) 2900 3000 3150 4300 6850 16000 20000 9000 20000 12000 10000 12000 Compact Fluorescent 5 7 9 13 26 32 250 400 600 860 1800 2400 10000 10000 10000 10000 10000 10000 Long Twin Tube Fluorescent 39 40 2850 3150 12000 20000 CLEAN Clean air, free of fumes and dust, luminaires scheduled to be cleaned frequently, and lamps replaced systematically. AVERAGE Luminaires Required = DIRTY Less favorable atmospheric conditions, luminaires cleaned at fairly frequent intervals, and lamps replaced only after burnout. Quite dirty locations and work atmospheres, infrequent maintenance of lighting equipment. Lamp and Luminaire Clean Average Dirty Incandescent Quartz Mercury Metal Halide High Pressure Sodium Fluorescent .74 .82 .70 .64 .69 .76 .65 .59 .64 .70 .60 .55 .77 .71 .71 .66 .66 .61 4e Calculate Lamp Lumens Required Formula: Total Lamp Lumens = Footcandles[†] X Area of Room (sq. ft.) Coefficient of Utilization[‡] X Light Loss Factor[ɍ] [†] from Table 1, page 665 or IES Handbook [‡] from catalog page on luminaire selected—and calculated from 4b [ɍ] from above ɍɍ For lamp data check current lamp manufacturing catalog. Variances exist between Total Lamp Lumens Total Lamp Lumens per Luminaire In using the formula make sure you divide by the total lamp lumens per luminaire. For example, if an EVF24022, 4 lamp, 32 watt, T8 luminaire is being used, you would multiply the total lamp lumens by 4. (4 × 2900 or 11,600 lumens.) manufacturers. Continued 686 STIBOINFO((CRH:66008com:L:686)) CH0 0 L - 1 0 US: 1-866-764-5454 CAN: 1-800-265-0502 © Copyright 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0687-5 Name: L-687 DATE: JAN 19 2006 Time: 5:43:13 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Industrial Lighting Products 4f (continued) EXAMPLE: Lumen Method Requirement: Design a system for lighting a room classified Class I, Division 2, Group D Assumptions: a) Room dimensions – 40′ wide; 80′ long; 15′ high b) Luminaires to be suspended 3′ from ceiling; work plane is 4′ above floor c) Ceiling is off-white; walls are light gray; floor is concrete d) Good maintenance conditions exist e) Lighting system will be operated 16 hours daily; 5 days a week f) Color rendition is not critical Using the Coefficient of Utilization worksheet, follow procedure given below. Answers to our example are on the worksheet. L (G) Compute Total Lamp Lumens required. Formula (FC x Area) 50 x 80 x 40 = 278,169 Lumens (CU x LLF) .747 x 0.77 Therefore, the number of VMVS3A150G luminaires required Total Lamp Lumens 278,169 = 17.4 Lamp Lumens per luminaire (page 686) 16,000 = 17 VMVS3A150G luminaires with RD70 dome reflectors (use 18 luminaires, see page 685). = Coefficient of Utilization Worksheet Step #1. Determine required illumination level in FOOTCANDLES (FC) – Table 1, page 665. Step #2. Select type of lamp – pages 666 and 667. For the room size in example, considering long hours of operation and color rendition not being critical, high pressure sodium lighting is recommended. Step #3. Select type of luminaire, page 668. VMV series Champ® luminaires are recommended. For our example VMVS3A150G pendant luminaire with RD70 dome reflector is selected. Step #4. Calculation of number of luminaires necessary. (A) Compute CAVITIES of ceiling, room and floor. HCC; HRC and HFC (see sketch on worksheet). (B) Obtain REFLECTANCE FACTORS (using values on page 685) RC; RW and RF (see sketch on worksheet). (C) Compute CAVITY RATIOS for ceiling, room and floor using Formula or Table IV, page 684. Formula 5 x HCC (L + W) CCR = LxW RCR = 5 x HRC (L + W) FCR = 5 x HFC (L + W) LxW LxW (D) Determine Effective Ceiling Reflectance from Table V, page 685. See work sheet for values of RC, RW and CCR. (E) Determine Coefficient of Utilization – from CU table. For a VMVS3A150G luminaire, applying an Effective Ceiling Cavity Reflectance of 70; a wall reflectance of 50 and a room Cavity Ratio of 1.5 (all figures applicable to our example), the CU (see CU Table, page 733) is at mid-point between .804 and .690, which is .747. (F) Determine Light Loss Factor (LLF) – page 686. US: 1-866-764-5454 STIBOINFO((CRH:66008com:L:687)) CH0 0 L - 1 1 Job Requirement: (See typical example at left) Given Data: (See typical assumptions at left) Lamp Characteristics: Type – High Pressure Sodium Catalog # – VMVS3A150G with RD70 dome reflector Lumens – 16,000 LLF – 0.77 No. of Footcandles Required: 50 Room: Length 80′ Width 40′ Height 15′ Cavities Reflectance Cavity Ratios: CCR 0.56 RCR 1.5 Effective Ceiling Cavity Reflectance: Wall Reflectance: CU: Total Lumens Required: No. of Luminaires: CAN: 1-800-265-0502 FCR 0.75 72 (use 70) 50 .747 278,170 18 luminaires (see page 686) Use 3 x 6 spacing Copyright© 2006 Cooper Crouse-Hinds 687 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0688-2 Name: L-688 L 100: DATE: JAN 19 2006 Time: 5:43:14 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Industrial Lighting Products Figure 2 (continued) 5 Determine Placement of Luminaires and Make Layout Using the number of units as determined in Step 4 as a basic quantity to work with, determine the number of lights per row and number of rows required for the lighting system. Logic plays a part; for example: if a room is 4 times as long as it is wide, you should have 4 times as many luminaires in each row as there are number of rows. In any case, the distance between the lighting units should not be greater than the mounting height of the units above the floor. The distance between the wall and first luminaire should not be more than 1⁄2 the spacing between the units, and in situations where work is done immediately adjacent to the wall, the distance should be reduced to 1⁄3 or 1⁄4 the distance between units. Four-Two system – equivalent to three units per bay or four per bay where spacing allows. In rooms that are divided by columns or beams, it is desirable to locate the units symmetrically in the bays. The following layouts will serve as a guide in planning such installations. Important: Remember to observe the permissible spacing to mounting height ratio or spacing criterion. If the number of luminaires is insufficient to fulfill this requirement, recalculate using lower wattage luminaires. Four units per bay – if necessary could run in continuous rows across room, or turned and run lengthwise with room. Figure 2 Typical Placement Incandescent/H.I.D., etc. Fluorescent One unit per bay – satisfactory only where the bay size is no greater than the maximum allowable spacing – an unusual condition. Two units per bay – usually applicable only in narrow bays, where the width is less than 2⁄3 the length. 688 STIBOINFO((CRH:66008com:L:688)) CH0 0 L - 1 2 US: 1-866-764-5454 CAN: 1-800-265-0502 Grid pattern – usual condition dependent on room size and type of work done there. Four units per bay – this is the most common system for the square bay of usual dimensions. Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0689-3 Name: L-689 100: DATE: JAN 19 2006 Time: 5:43:15 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Industrial Lighting Products L Point-by-Point Method EXAMPLE: Point-by-Point Method (for use in highlighting – see Step 4, page 683) #1 Determine the footcandle value at floor level immediately below a VDA22GRD with 200 Watt lamp and Dome reflector. Mounting height of unit above floor is 12′. #2 Using same unit as in #1, determine footcandle value at floor level at a point 7 feet away from luminaire. Use this method to determine the footcandle value at a point on a surface that is illuminated by direct light from a luminaire or luminaires. When the light hits a point on the surface head on (such as directly under a luminaire), use formula ‘‘A’’, but when the light hits the surface at an angle (such as between luminaires) formula ‘‘B’’ must be used. Figure 4/Methods of Measurement Figure 6 Problem #1 – use Formula ‘‘A’’ CP fc= x LLF d2 Fig. 5/Candlepower Distribution Curve Luminaire With Globe, Dome Reflector and With or Without Guard 200 Watt, A-23 Incandescent Formula ‘‘A’’ Footcandles = Candlepower Light Loss x factor d2 (Distance) 715(a) x 0.69(b) = 3.4 fc (12)2 (a) Candlepower at 0° (from Light Distribution Curve at left) fc= (b) Light loss factor from page 686 Candelas at 25 Feet Formula ‘‘B’’ Footcandles ⍧ Candlepower x cosine of angleΘ d2 (Distance) Light x Loss factor Mid-zone Angle 0 5 15 25 35 45 55 65 75 85 90 135 145 Without Guard 715 722 736 764 793 715 615 531 197 42 14 13 28 Problem #2 – use Formula ‘‘B’’ CP x CosΘ x LLF fc= d2 With Guard 575 575 595 650 674 605 534 473 166 35 14 12 21 779(c) x 0.866 x 0.69 = 2.4 fc (13.9)2 (c) Candlepower at 30° (from light Distribution Table at left). Interpolate between 25° and 35° fc= Candlepower (at the proper angle) is found from the Light Distribution Curve on the luminaire catalog page. Distance ‘‘d’’ and angle are found by measurement of a scaled sketch of the lighting situation or through trigonometric calculations. US: 1-866-764-5454 STIBOINFO((CRH:66008com:L:689)) CH0 0 L - 1 3 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 689 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0690-2 Name: Note Page-690 DATE: JAN 19 2006 Time: 5:43:16 PM Operator: JB COLOR: CMYK Notes Page 690 STIBOINFO((CRH:66008com::690)) CH0 3 A - 1 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0691-2 Name: 1L-691 100: DATE: JAN 19 2006 Time: 5:44:25 PM Operator: RB COLOR: CMYK TCP: 15001 Incandescent Luminaires Hazardous and Non-Hazardous Typedriver Name: TS name csm no.: 100 1L Description Page No. Application 692 Industrial Luminaires Vaporgard TM Series V Series NDA CorroɀGard TM Series US: 1-866-764-5454 STIBOINFO((CRH:66008com:1L:691)) CH0 0 0 0 1 L CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 693-701 702-705 706, 707 691 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0692-3 Name: 1L-692 1L 100: DATE: JAN 19 2006 Time: 5:44:25 PM Operator: JB Enclosed and Gasketed General Information Application: TCP: 15001 Table 500-3(d) Identification Numbers. Features: ɀ Enclosed and gasketed luminaires that accept incandescent lamps ɀ Gaskets and glass globes help prevent dirt, water and corrosive atmosphere from entering the conduit system and corroding the interior parts Standard Materials: Maximum Temperature Deg. C Deg. F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185 Identification Number T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 ɀ Luminaires-bodies, boxes and guards – copper-free aluminum or Feraloy® iron alloy ɀ Globes – heat-resistant glass or polycarbonate ɀ Reflectors – Krydon® fiberglass-reinforced polyester Standard Finishes: ɀ Vaporgard TM – copper-free aluminum-epoxy powder coat ɀ V SERIES, – Feraloy iron alloy – electrogalvanized and aluminum acrylic paint ɀ Krydon material – luminaires: gray; reflectors: high reflectance white Size Ranges: ɀ Include up to 300 watt, PS-30 lamp ɀ 1⁄2⍯ to 11⁄4⍯ hubs Certifications and Compliances: ɀ Weather resistant, NEMA 3, 3R ɀ NEC/CEC: Class I, Division 2 ɀ UL Standard: 1598 ɀ CSA Standard: C22.2 692 STIBOINFO((CRH:66008com:1L:692)) CH0 0 1 L - 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Typedriver Name: TS name csm no.: 100 CI. I, Div. 2, Groups A, B, C, D Weather Resistant Incandescent Luminaires Incandescent luminaires are used: ɀ indoors or outdoors in industrial locations ɀ in tunnels, building entrances or similar locations, where moisture, dirt, chemicals, vibration or rough usage are a problem ɀ either mounted directly in the conduit system or attached to cast outlet boxes, by means of pendant, ceiling, wall bracket or stanchion mountings COLOR: CMYK Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0693-4 Name: 1L-693 100: DATE: JAN 19 2006 Time: 5:44:26 PM Operator: RB VAPORGARD TM Incandescent Luminaires Standard Materials: Vaporgard series incandescent luminaires are used: ɀ indoors or outdoors in industrial locations where enclosed and gasketed fixtures are required ɀ in tunnels, building entrances and similar locations, where moisture, dirt, chemicals, vibration or rough usage are a problem ɀ for flush or surface mounting on ceiling or wall; pendant or in conduit systems; with or without a cast outlet box ɀ Bodies and guards – copper-free aluminum ɀ Globes – heat and impact resistant tempered glass – colored glass nontempered (G55, G56, G57, G58) – plastic polycarbonate (G63, G65, G67) ɀ Reflectors – Krydon® fiberglass-reinforced polyester Features: ɀ Bodies and guards – epoxy powder coat ɀ Krydon material – high reflectance white ® Krydon fiberglass-reinforced polyester reflectors ɀ Reflectance is equivalent to the finest porcelain enamel ɀ Cannot corrode – no enamel to chip and rust ɀ Ultraviolet inhibitors are incorporated in the material to prevent discoloration and brittleness Typedriver Name: TS name csm no.: 100 1L Standard Finishes: Options: The following options are available from the factory by adding suffix to fixture Cat. No.: Suffix to be Description Added to Cat. No.: ɀ Teflon coating on globe for increased shatter protection (G24 globe 200 watt series only) S808 ɀ 250V nameplate for export applications /250 ɀ Plastic polycarbonate globe See page 696 Ratings (Electrical/Size): ɀ Up to 300 watt, PS-30 medium base lamp ɀ 1/2⍯ to 1-1/4⍯ hubs ɀ 120V nameplate is standard – for NEC compliance ɀ 250V nameplate is optional. Supplied when ordered with suffix: /250 Certifications and Compliances: ɀ Wet locations ɀ NEC/CEC: Class I, Division 2 ɀ UL Standard: 1598 ɀ CSA Standard: C22.2 No. 9 ɀ UL/CSA Fixture Fitting US: 1-866-764-5454 STIBOINFO((CRH:66008com:1L:693)) TCP: 15001 Cl. I, Div. 2, Groups A,B,C,D (All mounting except stanchion) Wet Locations NEMA 3,3R Application: ɀ Designed to exclude dirt, moisture and corrosive vapors from the interior of the luminaires and the conduit system ɀ There are no screws to remove as the shock-absorbing socket strap is keyhole slotted and removes quickly for ease of wiring ɀ The glass globe-guard assembly is installed and/or removed as a unit, making it necessary to handle only one piece in relamping ɀ There are no crevices to accumulate a dirt or dust buildup and fixture has an attractive finish with a smooth, dust and dirt shedding design ɀ Configurated glass globe has vertical fluting and stippled bottom which provides for more even light distribution and glare elimination ɀ For non-hazardous locations, shatterproof plastic polycarbonate globes are available for use with the 200 watt series. ɀ Reversible offset socket mounting strap permits use of various size lamps while holding light center in same position for maximum light output and efficiency ɀ Shock absorbing medium base lamp socket CH0 0 1 L - 2 COLOR: CMYK CAN: 1-800-265-0502 Class I, Division 2 Temperature Performance Data: (Based on 40° C ambient) Lamp Watts T-Number Supply Wire °C 150 200 300 T2A T2B T2B 150°C 200°C 150° C Copyright© 2006 Cooper Crouse-Hinds 693 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0694-2 Name: 1L-694 1L 100: DATE: JAN 19 2006 Time: 5:44:27 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 2, Groups A,B,C,D Wet Locations NEMA 3,3R VAPORGARD TM Incandescent Luminaires Enclosed and Gasketed Luminaire Components Catalog Nos. Pendant Mount VDA Series Thru-Feed VDC Series Hub Max Lamp Size Series Size Complete Cat.# with globe/guard Pendant Body Globe Guard 1⁄2⍯ VDA15GP VDA25GP VDA15 VDA25 G54 G54 P50 P50 VDA35GP VDA35 G54 P50 VDA12GP VDA22GP VDA12 VDA22 G24 G24 P21 P21 VDA32GP VDA32 G24 P21 VDA13GP VDA23GP VDA13 VDA23 G34/G251 P22 G34/G251 P22 VDA33GP VDA33 G34/G251 P22 Hub Max Lamp Size Series Size Complete Cat.# with globe/guard Thru Feed Body Globe Guard 1⁄2⍯ 3⁄4⍯ 150 150 1⍯ 150 1⁄2⍯ 3⁄4⍯ 200 200 1⍯ 200 1⁄2⍯ 3⁄4⍯ 300 300 1⍯ 300 150 watt A-21 200 watt A-23 300 watt PS-25 & PS-30 150 150 150 watt A-21 VDC15GP VDC25GP VDC15 VDC25 G54 G54 P50 P50 200 200 200 watt A-23 VDC12GP VDC22GP VDC12 VDC22 G24 G24 P21 P21 300 300 300 watt PS-25 & PS-30 VDC13GP VDC23GP VDC13 VDC23 G34/G251 P22 G34/G251 P22 Hub Max Lamp Size Series Size Complete Cat.# with globe/guard Lamp Socket Body Globe Guard 1⁄2⍯ 150 150 watt A-21 VXH15GP VXH15 G54 P50 1⁄2⍯ 200 VXH12GP VXH12 G24 P21 1⁄2⍯ 300 200 watt A-23 300 watt PS-25 & PS-30 VXH13GP VXH13 G34/G251 P22 Hub Size Max Lamp Series Size Complete Cat.# with globe/guard Lamp Socket Body Globe Guard Junction Box 1⁄2⍯ 150 150 150 watt A-21 VXHF15GP VXHF25GP VXH15 VXH15 G54 G54 P50 P50 VXF10 VXF20 200 200 200 watt A-23 VXHF12GP VXHF22GP VXH12 VXH12 G24 G24 P21 P21 VXF10 VXF20 300 300 300 watt PS-25 & PS-30 VXHF23GP VXHF23GP VXH13 VXH13 G54/G251 P22 G34/G251 P22 VXF20 VXF20 3⁄4⍯ 1⁄2⍯ 3⁄4⍯ 1⁄2⍯ 3⁄4⍯ Ceiling Mount for Recessed 4⍯ Round Box - VXH Series Ceiling Mount with Junction Box VXHF Series 3⁄4⍯ 1⁄2⍯ 3⁄4⍯ 1⁄2⍯ 3⁄4⍯ – available with Lightning Service TM See Section G for complete details 694 STIBOINFO((CRH:66008com:1L:694)) CH0 0 1 L - 3 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0695-2 Name: 1L-695 100: DATE: JAN 19 2006 Time: 5:44:28 PM Operator: JB VAPORGARD TM Incandescent Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 2, Groups A,B,C,D Wet Locations NEMA 3,3R 1L Enclosed and Gasketed Wall Mount VXHT Series Luminaire Components Catalog Nos. Hub Max Lamp Size Series Size Complete Cat.# with globe/guard Wall Bracket Mounting Module Body 1⁄2⍯ 3⁄4⍯ 1⁄2⍯ 3⁄4⍯ 1⁄2⍯ 3⁄4⍯ Wall Mount Adapter Kit Globe Guard 150 150 150 watt A-21 VXHT15GP VXHT25GP VXT10 VXT20 VXH15 VXH15 G54 G54 P50 P50 200 200 200 watt A-23 VXHT12GP VXHT22GP VXT10 VXT20 VXH12 VXH12 G24 G24 P21 P21 300 300 300 watt VXHT13GP PS-25 & PS-30 VXHT23GP VXT10 VXT20 VXH13 VXH13 G34/G251 P22 G34/G251 P22 Mounts wall mount VXHT Series to a 4⍯ Round Box. Cat. No. VXT-K1 Wall Mount with Junction Box VXHBF Series Hub Max Lamp Size Series Size Complete Cat.# with globe/guard Wall Bracket Mounting Module Body 1⁄2⍯ 3⁄4⍯ 1⁄2⍯ 3⁄4⍯ 1⁄2⍯ 3⁄4⍯ Stanchion Mount VXHA Series Junction Guard Box 150 150 150 watt A-21 VXHBF15GP VXHBF25GP VXT10 VXT20 VXH15 VXH15 G54 G54 P50 P50 VXF10 VXF20 200 200 200 watt A-23 VXHBF12GP VXHBF22GP VXT10 VXT20 VXH12 VXH12 G24 G24 P21 P21 VXF10 VXF20 300 300 300 watt VXHBF13GP PS-25 & PS-30 VXHBF23GP VXT10 VXT20 VXH13 VXH13 G34/G251 P22 G34/G251 P22 VXF10 VXF20 Complete Cat.# with globe/guard Stanchion Mounting Module Body Globe Guard VXHA45GP VXA4 VXH15 G54 P50 200 watt VXHA42GP A-23 300 watt VXHA43GP PS-25 & PS-30 VXA4 VXH12 G24 P21 VXA4 VXH13 G34/G251 P22 Hub Max Lamp Size Series Size 1 Globe 1⁄4⍯ 1 1⁄4⍯ 1 1⁄4⍯ 150 watt A-21 – available with Lightning Service TM See Section G for complete details US: 1-866-764-5454 STIBOINFO((CRH:66008com:1L:695)) CH0 0 1 L - 3 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 695 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0696-7 Name: 1L-696 DATE: JAN 19 2006 Time: 5:44:30 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 VAPORGARD TM Incandescent Luminaires 1L Parts and Accessories Medium Base Lamp Receptacle with Strap Plastic Globes 1 Globes† and Guards Shock Absorbing Cat. # V84 150 and 200W globe 300W globe Reflectors Color Clear (heatresisting) Green Blue Red Amber Dome Maximum Lamp Size 150 Watt, 200 Watt, 300 Watt, A-21 A-23, A-25, PS-25 PS-25 PS-30‡ Application: Cat. # Cat. # Features: G54 G55* G56* G57* G58* G24ɍ G25 G26 G27 G28 Cat. # G34 {G251 30° Angle Max. Lamp Size 150 watt, A-21 200 watt, A-23, A-25, PS-25 and 300 watt, PS-30 Dome Cat. # RD64 30° Angle Cat. # RA64 RD71 RA71 Shatterproof polycarbonate plastic globe** Guard P50 and P21 Guard P22 Guards for Glass Globes (Not for use with plastic globes) Cat. # Maximum Lamp Size P50 150 watt, A-21 P21 200 watt, A-23, A-25, PS-25 P22 300 watt, PS-30 (with G251 only) For use in: ɀ food processing plants and canneries, dairies, breweries and bakeries ɀ emergency lighting ɀ Shatterproof, which precludes contamination of food products with broken particles of glass. ɀ Designed to comply with U.S. Dept. of Agriculture specification for food processing plants. ɀ Provides protection against vandalism, with resultant lower replacement and maintenance costs. ɀ Particularly adaptable for use on emergency police or fire alarm boxes. ɀ Same size as G24 series glass globes. Existing installations can be changed to plastic globes simply by replacing globe. ɀ For use with 200 watt series luminaires such as VDA22, etc. ɀ For use without guard. Max. Wattage, Color Lamp Size Cat. # Natural 200 watt, A-23 G63 Green 200 watt, A-23 G65 Red 200 watt, A-23 G67 Note: Polycarbonate globes for nonhazardous locations only. Mounting Adapter Kit ɀ Allows for the mounting of non-CrouseHinds outlet boxes to the VXT20 wall mount bracket and VXH ceiling mount bracket Cat. # VXT-K1 VXFT – 5 Hubs, 4 Plugs Hub Size Cat. # 1⁄2 VXFT10 3⁄4 VXFT20 For use when rear wiring entry is required. Use in lieu of VXF10 or VXF20. VXT-K1 ɍ G24 is available with a TEFLON coating for increased shatter protection by adding suffix S808. * With G55, G56, G57, G58 color globes, maximum lamp size is 60 watt for outdoor applications. ** Prior to wash-down, globes must be cool. † All glass globes are configured type, having fluted side and stippled bottom. ‡ Globe G251 required when guard P22 is used. Use globe G34 when guard is not used. 1 Lamp must be mounted in vertical position base up to 45°C (stanchion) only. ® – available with Lightning Service TM See Section G for complete details 696 STIBOINFO((CRH:66008com:1L:696)) CH0 0 1 L - 7 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0697-9 Name: 1L-697 100: DATE: JAN 19 2006 Time: 5:44:32 PM Operator: RB VAPORGARD TM Series Incandescent Luminaires COLOR: CMYK TCP: 15001 Family Tree Typedriver Name: TS name csm no.: 100 1L – available with Lightning Service TMSee Section G for complete details US: 1-866-764-5454 STIBOINFO((CRH:66008com:1L:697)) CH0 1 L - 1 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 697 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0698-1 Name: 1L-698 1L 100: DATE: JAN 19 2006 Time: 5:44:33 PM Operator: JB VAPORGARD TM Incandescent Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Luminaire With Globe, 30° Angle Reflector and With or Without Guard Luminaire VXHA45GPRA Lamp: 150W/A-21 Total Bare Lamp Lumens: 2850 Total Lumens Eff. % With Guard 1490 52.3 Without Guard 1881 66.0 Lamp: 100W/A-21 through 200W/A-23 Total Bare Lamp Lumens: 4000 NOTE: All data provided is for 200W/A-23 incandescent lamp. Use following candlepower/lumen multipliers for other lamp sizes: 100W 0.42; 150W 0.7 Measurements taken from A-A′ plane. Measurements taken from A-A′ plane. Luminaire VXHA42GPRA Lamp: 300W/PS-30 Total Bare Lamp Lumens: 6300 Total Lumens Eff. % With Guard Without Guard 3630 57.6 4271 67.8 Lamp Size 100W 150W 200W/A-23 200W/PS-25 Without Guard Total Lumens Eff. % 1141 1890 2700 67.5 2174 With Guard Total Lumens Eff. % 949 1582 2260 56.5 1819 Luminaire With Globe, 30° Angle Reflector and With or Without Guard Lamp: 300W/PS-30 Total Bare Lamp Lumens: 6000 Total Lumens Eff. % With Guard Without Guard Measurements taken from A-A′ plane. Measurements taken from A-A′ plane. 698 STIBOINFO((CRH:66008com:1L:698)) CH0 0 1 L - 8 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 3360 56.0 3954 65.9 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0699-2 Name: 1L-699 DATE: JAN 19 2006 Time: 5:44:34 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data VAPORGARD TM Incandescent Luminaires 1L Lamp: 100W/A-21 through 200W/PS-25 Total Bare Lamp Lumens: 4000 To determine number and placement of luminaires see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for 200W/A-23 incandescent lamp. Use following candela/lumen multipliers for other lamp sizes: 100W 0.42; 150W 0.7; 200W/PS-25 0.82 Luminaire With Globe and With or Without Guard Luminaire With Globe, Dome Reflector and With or Without Guard Example: Zonal Lumens for 200W/A-23 lamp with guard for 0-40° is 272 Zonal Lumens for 150W lamp with guard for 0-40° is 272 × 0.7 ⍧ 190. Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .654 .549 .471 80 30 .608 .486 .400 10 .567 .432 .345 50 .603 .506 .434 70 30 .563 .449 .370 10 .523 .401 .320 50 .509 .424 .363 50 30 .477 .380 .313 10 .449 .341 .271 50 .422 .349 .297 30 30 .399 .315 .259 10 .376 .285 .225 50 .343 .280 .237 10 30 .324 .253 .206 10 .307 .230 .180 4 .407 .333 .277 .375 .309 .257 .312 .260 .218 .255 .214 .180 .202 .170 .143 5 .353 .282 .228 .326 .260 .211 .273 .220 .179 .223 .180 .147 .176 .142 .115 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .604 .522 .454 80 30 .576 .480 .404 10 .552 .444 .364 50 .591 .512 .445 70 30 .565 .472 .398 10 .543 .440 .361 50 .564 .490 .428 50 30 .544 .457 .387 10 .526 .428 .354 50 .541 .470 .411 30 30 .525 .444 .377 10 .509 .419 .348 50 .521 .452 .396 10 30 .507 .429 .367 10 .494 .409 .342 4 .395 .340 .298 .387 .336 .296 .372 .327 .292 .358 .319 .288 .345 .311 .283 5 .347 .290 .248 .339 .286 .246 .327 .280 .245 .315 .273 .241 .304 .268 .238 % Reflectance Eff Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 9 .226 .162 .118 .208 .150 .110 .175 .126 .092 .143 .103 .075 .114 .080 .057 10 .201 .140 .100 .185 .130 .093 .156 .109 .077 .128 .088 .061 .101 .068 .045 Reflectance Eff Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 9 .222 .170 .135 .219 .168 .135 .211 .166 .134 .204 .162 .133 .198 .159 .131 10 .193 .142 .110 .189 .142 .110 .184 .139 .109 .178 .136 .107 .173 .134 .106 Room Cavity Ratio 6 7 8 .315 .279 .249 .244 .210 .183 .193 .164 .137 .289 .257 .230 .225 .194 .170 .177 .150 .127 .242 .215 .192 .189 .163 .143 .150 .126 .106 .198 .175 .158 .155 .134 .116 .123 .102 .086 .157 .140 .124 .122 .106 .091 .096 .080 .066 US: 1-866-764-5454 STIBOINFO((CRH:66008com:1L:699)) CH0 0 1 L - 9 Example: Zonal Lumens for 200W/A-23 lamp with guard for 0-40° is 948 Zonal Lumens for 150W lamp with guard for 0-40° is 948 × 0.7 ⍧ 664. CAN: 1-800-265-0502 Room Cavity Ratio 6 7 8 .309 .274 .244 .253 .220 .192 .214 .184 .155 .303 .270 .241 .250 .217 .191 .211 .181 .154 .291 .260 .232 .245 .212 .186 .209 .179 .153 .281 .250 .225 .239 .209 .182 .207 .177 .152 .272 .243 .217 .234 .205 .179 .205 .175 .150 Copyright© 2006 Cooper Crouse-Hinds 699 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0700-2 Name: 1L-700 1L DATE: JAN 19 2006 Time: 5:44:35 PM Operator: RB VAPORGARD TM Incandescent Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Lamp: 300W/PS-30 Total Bare Lamp Lumens: 6000 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. Luminaire With Globe Only Luminaire With Globe and Dome Reflector Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .692 .582 .499 80 30 .644 .515 .425 10 .602 .459 .367 50 .636 .534 .458 70 30 .594 .475 .392 10 .552 .425 .339 50 .532 .444 .380 50 30 .500 .398 .328 10 .470 .358 .285 50 .437 .362 .308 30 30 .412 .326 .268 10 .389 .295 .234 50 .350 .285 .241 10 30 .331 .258 .210 10 .313 .235 .183 4 .431 .354 .295 .396 .327 .273 .327 .272 .229 .264 .222 .186 .205 .172 .145 5 .373 .300 .243 .345 .276 .223 .286 .230 .188 .230 .186 .152 .179 .144 .116 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .766 .671 .587 80 30 .734 .621 .528 10 .706 .579 .482 50 .750 .657 .577 70 30 .720 .610 .521 10 .694 .573 .477 50 .717 .630 .555 50 30 .693 .592 .507 10 .672 .558 .468 50 .688 .606 .535 30 30 .670 .575 .494 10 .651 .546 .460 50 .663 .584 .516 10 30 .647 .557 .482 10 .632 .534 .452 4 .514 .448 .398 .505 .444 .395 .485 .432 .390 .468 .422 .385 .452 .412 .379 5 .454 .385 .334 .443 .380 .332 .429 .372 .329 .414 .364 .325 .400 .357 .321 % Reflectance Eff Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 9 .238 .170 .125 .219 .157 .115 .181 .131 .095 .146 .105 .075 .114 .080 .055 10 .212 .147 .105 .194 .136 .097 .162 .113 .079 .130 .090 .061 .101 .067 .044 % Reflectance Eff Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 9 .293 .229 .185 .288 .227 .185 .279 .223 .184 .270 .218 .182 .262 .215 .180 10 .254 .191 .151 .249 .191 .151 .243 .187 .150 .235 .184 .148 .229 .181 .146 700 STIBOINFO((CRH:66008com:1L:700)) CH0 1 L - 1 0 Room Cavity Ratio 6 7 8 .333 .295 .263 .258 .223 .194 .205 .173 .145 .305 .271 .241 .238 .204 .178 .188 .158 .133 .253 .224 .200 .198 .170 .148 .157 .132 .110 .204 .180 .162 .160 .138 .119 .127 .105 .088 .158 .141 .124 .123 .106 .091 .096 .079 .066 US: 1-866-764-5454 CAN: 1-800-265-0502 Room Cavity Ratio 6 7 8 .404 .360 .322 .337 .294 .258 .289 .250 .212 .397 .354 .317 .333 .290 .256 .285 .246 .211 .383 .342 .306 .326 .284 .250 .283 .244 .209 .371 .330 .297 .320 .280 .245 .281 .241 .208 .359 .322 .288 .313 .275 .241 .277 .239 .206 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0701-1 Name: 1L-701 100: DATE: JAN 19 2006 Time: 5:44:36 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 VAPORGARD TM Incandescent Luminaires 1L Dimensions a b c d e f g h j 150 watt, A-21 127⁄8 111⁄8 53⁄8 313⁄16 87⁄16 12 813⁄16 9 41⁄2 200 watt, PS-25 167⁄8 145⁄8 6 4 91⁄8 14 101⁄2 1013⁄16 611⁄16 300 watt, PS-30 167⁄8 145⁄8 6 4 91⁄8 14 12 131⁄8 611⁄16 VDA Series VDC Series VXH and VXHF Series (omit box for VXF Series) VXHT and VXHBF Series (NOTE: Omit box for VXHB series) Max. Lamp Size 150 watt, A-21 a 53⁄8 200 watt, A-23, A-25, PS-25 and 300 watt, PS-30 6 US: 1-866-764-5454 STIBOINFO((CRH:66008com:1L:701)) CH0 1 L - 1 1 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 701 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0702-2 Name: 1L-702 DATE: JAN 19 2006 Time: 5:44:37 PM Operator: RB V-Series Incandescent Luminaires 1L COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Wet Locations NEMA 3,3R Enclosed and Gasketed Application: Standard Materials: V-Series incandescent luminaires are used: ɀ indoors or outdoors in industrial locations where enclosed and gasketed fixtures are required ɀ in tunnels, building entrances and similar locations, where moisture, dirt, chemicals, vibration or rough usage are a problem ɀ for flush or surface mounting on ceiling or wall, with or without a cast outlet box, pendant or in conduit systems ɀ Bodies – Feraloy® iron alloy ɀ Guards – copper-free aluminum ɀ Globes – glass ɀ Reflectors – Krydon® fiberglass-reinforced polyester material reflectors Certifications and Compliances: ɀ Wet locations ɀ NEMA: 3, 3R ɀ UL Standard: 1598 Standard Finishes: ɀ Feraloy iron alloy – electrogalvanized and aluminum acrylic paint ɀ Copper-free aluminum – natural ɀ Krydon® material – high reflectance white Features: ɀ Designed to exclude dirt, moisture and corrosive vapors from the interior of the fixtures and the conduit system. ɀ Several body styles provide a wide variety of mountings, while all use the same globes, guards and optional accessories. ɀ Rugged and corrosion resistant. Size Ranges: ɀ 3⁄4 hubs ɀ Maximum wattage lamp: - Glass globes 150W, A23 - Polycarbonate 75W, A33 Options: Description Corro-free TM epoxy powder coat Suffix S752 plastic polycarbonate globe Order separately. See below VDA VC VG VJ VD Description With plain globe and guard Cat. # VDA2759 Cat. # VC2759 Cat. # VG2759 Cat. # VJ2759 Cat. # VD2759 Without globe and guard VDA275 VC275 VG275 VJ275 VD275 Glass Globes Guard For Glass Globes Polycarbonate Globes Application: Polycarbonate globes are used: ɀ in food processing plants, canneries, dairies, breweries and bakeries ɀ in emergency lighting ɀ emergency police and fire alarm boxes Features: ɀ Polycarbonate globes are shatterproof, preclude contamination of food products with broken particles of glass. ɀ Comply with U.S. Dept. of Agriculture specification for food processing plants. V63 Color Clear (heat resisting) Green Blue Red Amber 702 STIBOINFO((CRH:66008com:1L:702)) CH0 1 L - 1 2 Cat. # V63 VN72 VN73 VN75 VN76 V911 Globe Size 63⁄4⍯ Cat. # V911 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds V470 Color Natural Red Cat. # V470 V475 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0703-3 Name: 1L-703 DATE: JAN 19 2006 Time: 5:44:39 PM Operator: RB COLOR: CMYK TCP: 15001 Incandescent Luminaires Typedriver Name: TS name csm no.: 100 1L Accessories and Parts For V-Series Dome Receptacles (medium base) Cat. # V46 Angle Gasket Cat. # GASK213 Reflectors Krydon® – fiberglass-reinforced polyester (Must be used with V 911 Guard) Lamp Size 50-150W Lamp Size 50-150W Dome Dia. Cat. # 12⍯ RD60 30° Angle Dia. Cat. # 12⍯ RA60 NOTE: Angle reflector cannot always be used with bracket style fixtures. Check distance from mounting surface to center of body against reflector size to determine if reflector will fit. US: 1-866-764-5454 STIBOINFO((CRH:66008com:1L:703)) CH0 1 L - 1 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 703 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0704-1 Name: 1L-704 100: DATE: JAN 19 2006 Time: 5:44:40 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 V-Series Incandescent Luminaires 1L Enclosed and Gasketed Dimensions VC Hub Size 1⁄2 3⁄4 VDA a 7⁄8 7⁄8 c 311⁄16 311⁄16 d 4 4 h 63⁄16 63⁄16 VD k 49⁄16 49⁄16 VG Hub Size 1⁄2 3⁄4 a 415⁄16 415⁄16 b 43⁄16 43⁄16 c 515⁄16 63⁄16 g 21⁄2 23⁄4 h 63⁄16 63⁄16 k 49⁄16 49⁄16 b 113⁄16 115⁄16 c 47⁄8 47⁄8 d 3⁄8 e 53⁄8 53⁄8 h 63⁄16 63⁄16 k 49⁄16 49⁄16 VJ c 47⁄8 47⁄8 704 STIBOINFO((CRH:66008com:1L:704)) CH0 1 L - 1 6 Hub Size 1⁄2 3⁄4 h 63⁄16 63⁄16 Hub Size 1⁄2 3⁄4 k 49⁄16 49⁄16 US: 1-866-764-5454 CAN: 1-800-265-0502 3⁄8 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0705-2 Name: 1L-705 DATE: JAN 19 2006 Time: 5:44:41 PM Operator: RB COLOR: CMYK TCP: 15001 Photometric Data V-Series Incandescent Luminaires Typedriver Name: TS name csm no.: 100 1L Enclosed and Gasketed Luminaires V-Series Lamp: 150W/A23 Clear Total Bare Lamp Lumens: 2800 To determine number and placement of fixtures, see Lighting Selector Guide pages 665 to 689. Zonal Lumens NOTE: All data provided is Without With for 150W incandescent Zone Guard Guard lamp. Use following 0-10 29 19 10-20 67 60 candela/lumen multipliers 20-30 109 60 for the other lamp sizes: 30-40 127 113 40-50 175 168 100W – 0.61 50-60 218 117 60-70 246 250 Example: Zonal lumens 70-80 228 232 80-90 223 65 for 150W lamp for 0-40° 90-100 209 218 with guard is 252. 100-110 210 218 110-120 210 120-130 194 130-140 164 140-150 87 150-160 3 Total 2499 216 72 165 58 8 2039 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 50 80 30 10 Room Cavity Ratio 1 2 3 .659 .558 .479 .623 .504 .417 .591 .458 .367 4 .416 .349 .298 5 .361 .298 .248 70 50 30 10 .609 .577 .545 .515 .466 .426 .442 .386 .342 .384 .324 .278 .336 .275 .230 50 50 30 10 .515 .491 .469 .434 .397 .364 .372 .328 .293 .321 .274 .238 .282 .234 .197 30 50 30 10 .429 .411 .395 .359 .332 .307 .307 .274 .245 .264 .228 .198 .232 .194 .165 10 50 30 10 .350 .337 .325 .290 .269 .251 .246 .221 .199 .211 .183 .160 .185 .156 .132 Room Cavity Ratio 6 7 8 .325 .290 .261 .259 .227 .199 .212 .183 .157 9 .236 .176 .136 10 .211 .153 .116 % Reflectance Eff. Ceil. Wall 50 80 30 10 70 50 30 10 .299 .240 .197 .268 .210 .170 .241 .186 .146 .219 .164 .127 .194 .143 .108 50 50 30 10 .252 .205 .169 .226 .178 .145 .203 .158 .125 .185 .140 .109 .165 .122 .092 30 50 30 10 .208 .170 .141 .186 .149 .121 .169 .131 .105 .153 .117 .091 .137 .101 .076 10 50 30 10 .167 .136 .114 .151 .121 .098 .135 .106 .084 .124 .094 .073 .110 .081 .060 US: 1-866-764-5454 STIBOINFO((CRH:66008com:1L:705)) CH0 1 L - 1 7 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 705 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0706-1 Name: 1L-706 1L DATE: JAN 19 2006 Time: 5:44:42 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 2, Groups A,B,C,D Corrosive Wet Locations NEMA 3,3R,4,4X NDA CorroɀGard TM CorrosionResistant Incandescent Luminaires NDA Series Ordering Information Application: CorroɀGard TM NDA series Luminaires made of Krydon® fiberglass-reinforced polyester are used to provide incandescent lighting: ɀ indoors or outdoors in industrial wet or dirty locations and where corrosion is a problem ɀ in marine applications, above and below deck, where salt spray corrosion shortens fixture life ɀ in food and beverage industries where frequent wash-downs are necessary ɀ for walkways, bridges, tunnels, security lighting, cold storage facilities, garages, coal handling areas, shipboard, processing plants, and nuclear generating plant containment areas For Pendant Mounting Hub Size 3⁄4⍯ Max. Lamp Size 300W PS-25 Med. Base 120V Body Only Cat. # NDA22 Globe Only Cat. # G24 Temperature Performance Data: Features: ɀ Luminaire is molded Krydon for excellent corrosion, heat, and impact resistance. ɀ Accommodates all popular incandescent lamps up to 300W, PS-25. ɀ Attractive modern design and color complement other CorroɀGard products. ɀ Weighs only 81⁄2 lbs. complete with lamp and globe. ɀ Medium screw base porcelain lamp socket has a vibration absorbing mounting bracket. ɀ All joints are gasketed to ensure watertightness. ɀ Configured glass globe reduces glare. ɀ CorroɀGard reflectors made of Krydon® reflect light better than porcelainized steel; do not yellow or discolor with age; cannot chip, peel, rust or dent. ® Certifications and Compliances: ɀ UL Standard: 1598 ɀ Wet Locations ɀ Suitable for 40°C ambient temperature (based on 40°C ambient) Max. Lamp Size T-Number 300W T2A (Note: Fixtures are not marked with T-Number.) Dimensions Standard Materials: ɀ Bodies and reflectors – Krydon® fiberglassreinforced polyester material ɀ Globes – configured heat-resistant glass Standard Finishes: ɀ Bodies – natural ɀ Reflectors – natural, high reflectance white Options: ɀ TEFLON® coating on G24 globe for increased shatter protection. . . . . . . add suffix S808. Accessories & Parts Globe Replacement Lamp Receptacles with Strap Reflectors (Order separately) Shock Absorbing Guard Dome Cat No. NV84 Color Clear (heat resisting) Green Blue Red Amber 706 STIBOINFO((CRH:66008com:1L:706)) CH0 1 L - 2 0 Body With Globe‡ Cat. # NDA22G Cat. # G24 G25 G26 G27 G28 Cat. # P21 30° Angle Type Dome 30° Angle US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Cat. # RD725 (RD75) RA725 (RA75) Supply Wire (°C) 150°C Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0707-2 Name: 1L-707 DATE: JAN 19 2006 Time: 5:44:43 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data NDA CorroɀGard TM CorrosionResistant Incandescent Luminaires 1L Lamp: 200W/PS-25 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for incandescent with 200W/PS-25 lamp. See Multipliers for other wattages and lamp types. Luminaire With Globe Luminaire With Globe and Dome Reflector Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil.Wall 1 2 3 4 50 .762 .651 .565 .494 80 30 .715 .585 .491 .416 10 .673 .529 .433 .357 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil.Wall 1 2 3 4 50 .809 .703 .615 .541 80 30 .773 .647 .550 .470 10 .742 .601 .499 .416 5 .433 .358 .300 CANDLES AT 25 FT. IN PLANE A-A’ WITHOUT GUARD DEGREES FRONT BACK 0 630 5 646 619 10 672 577 15 677 539 20 677 498 25 677 465 30 677 422 35 677 388 40 640 338 45 630 278 50 630 89 55 625 24 60 583 5 65 551 70 525 75 461 80 422 85 385 90 346 95 310 100 273 105 207 110 68 115 24 120 5 125 130 5 .481 .408 .354 Total Lumens 2595 Eff. % 80.6 70 50 30 10 .708 .667 .626 .605 .546 .496 .526 .460 .407 .461 .390 .336 .406 .335 .282 70 50 30 10 .791 .758 .729 .688 .636 .595 .604 .542 .494 .531 .465 .413 .470 .403 .315 50 50 30 10 .608 .576 .547 .519 .473 .432 .452 .399 .356 .395 .339 .295 .292 .250 .248 50 50 30 10 .756 .729 .706 .659 .617 .579 .580 .528 .485 .510 .453 .408 .455 .395 .349 Multipliers for Other Lamps 30 50 30 10 .516 .492 .469 .439 .404 .372 .382 .342 .307 .335 .290 .254 .297 .250 .215 30 50 30 10 .726 .705 .684 .634 .599 .566 .558 .514 .477 .492 .442 .402 .439 .385 .344 Photometric data was developed using a 200 watt/PS-25 inside frosted incandescent lamp (3,220 lumens). For other incandescent watts/lamp size, use the following conversion factors (multipliers): 10 50 30 10 .433 .413 .396 .366 .339 .315 .319 .287 .259 .279 .244 .215 .247 .211 .181 10 50 30 10 .699 .663 .580 .610 .580 .553 .539 .501 .468 .475 .431 .396 .424 .378 .340 0 0 .354 .277 .226 .184 .154 0 0 .647 .536 .451 % Reflectance Eff. Ceil.Wall 50 80 30 10 .378 .323 Room Cavity Ratio 6 7 8 .431 .386 .347 .360 .317 .280 .309 .269 .231 9 .317 .250 .204 10 .277 .211 .169 70 50 30 10 .423 .356 .305 .380 .312 .265 .342 .277 .231 .312 .247 .204 .272 .211 .169 .205 .153 .117 50 50 30 10 .408 .348 .303 .368 .305 .263 .331 .272 .229 .302 .243 .202 .265 .207 .167 .197 .152 .121 .175 .131 .100 30 50 30 10 .396 .342 .300 .355 .301 .260 .321 .266 .227 .294 .238 .201 .257 .203 .165 .180 .144 .116 .166 .129 .102 .147 .110 .084 10 50 30 10 .383 .334 .297 .346 .295 .258 .311 .262 .225 .285 .235 .199 .250 .200 .163 .096 .084 .068 0 0 .281 .243 .210 .184 .150 Room Cavity Ratio 6 7 8 .389 .348 .312 .312 .273 .240 .258 .222 .190 9 .284 .214 .166 10 .253 .185 .141 70 50 30 10 .363 .293 .242 .324 .256 .208 .291 .226 .179 .266 .201 .157 .236 .175 .133 50 50 30 10 .312 .256 .213 .280 .223 .183 .252 .198 .158 .230 .177 .139 30 50 30 10 .266 .220 .185 .238 .193 .158 .216 .170 .137 10 50 30 10 .223 .185 .156 .201 .163 .135 0 0 .132 .112 % Reflectance Eff. Ceil.Wall 50 80 30 10 US: 1-866-764-5454 STIBOINFO((CRH:66008com:1L:707)) CH0 1 L - 1 5 Luminaire With Globe and 30° Angle Reflector CAN: 1-800-265-0502 Watts 100 100 Lamp Size A-19 A-21 Lamp Lumens 1750 1690 Conversion Factor .54 .52 150 150 A-21 PS-25 2880 2680 .89 .83 200 A-23 4010 1.25 300 PS-25 6360 1.98 Example: Zonal lumens for 200W/PS-25 luminaire with globe and dome reflector for 30-40° is 389. Zonal lumens for 100W/A-21 luminaire with globe and dome reflector for 30-40° is 389 × .52 ⍧ 202. Copyright© 2006 Cooper Crouse-Hinds 707 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0708-2 Name: Note Page-708 DATE: JAN 19 2006 Time: 5:44:44 PM Operator: TB COLOR: CMYK Notes Page 708 STIBOINFO((CRH:66008com::708)) CH0 3 A - 1 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0709-3 Name: 2L-709 100: DATE: JAN 19 2006 Time: 5:44:45 PM Operator: RB COLOR: CMYK TCP: 15001 Incandescent Luminaires Hazardous Typedriver Name: TS name csm no.: 100 2L Description Page No. Application/Selection Page 710 Class I Hazardous Area Luminaires EVI Series Groups C, D EV Series Groups A, B, C, D US: 1-866-764-5454 STIBOINFO((CRH:66008com:2L:709)) CH0 0 0 0 2 L CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 711-719 720 709 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0710-3 Name: 2L-710 2L 100: DATE: JAN 19 2006 Time: 5:45:48 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Incandescent Luminaires Hazardous Application and Selection Application: ɀ For use in areas made hazardous by presence of flammable vapors, gases, or dusts ɀ For indoor or outdoor use. For general area or spot lighting Considerations for Selection: Environmental: ɀ What is the hazardous area classification (NEC)/(CEC) of the location in which the luminaires will be installed? Lighting levels required: ɀ What wattage fixture(s) will provide the desired light level? (See Lighting Selector Guide, pages 665 through 689, to determine number and location of luminaires required.) Physical arrangement: ɀ Type of luminaire mounting needed Product Selection: Two product families are included in Section 2L as follows: ɀ EVI models suitable for use in Class I, Groups C, D, and Class II, Groups E, F and G locations. These luminaires may be ordered with a wide variety of reflector styles and mounting arrangements to provide the required light distribution, depending on application, mounting height and lamp size. Check individual catalog pages for specific hazardous location suitabilities of each luminaire. Models are available for lamp sizes 100 watt, A-19 to 500 watt, PS-40. ɀ EV Models suitable for use in Class 1, Groups A, B, C, D locations. These luminaires may be ordered with a wide variety of reflector styles and arrangements to provide the required light distribution, depending on application, mounting height and lamp size. Check individual catalog pages for specific hazardous location suitabilities of each luminaire. Models are available for lamp size 300 watt PS35 mogul base. Table 500-3(d) Identification Numbers. Maximum Temperature Deg. C Deg. F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185 710 STIBOINFO((CRH:66008com:2L:710)) CH0 0 2 L - 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Identification Number T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0711-12 Name: 2L-711 DATE: JAN 19 2006 Time: 5:45:49 PM Operator: RB EVI Series Explosionproof Incandescent Luminaires Factory Sealed 100-500W Medium and Mogul Base Application: Features: ɀ Ambient suitability to 65°C. ɀ Standard 90°C rated building wire for 150W max 40°C ambient application - represents more than 75% of all applications. ɀ Type 4X, marine outdoor locations. ɀ Factory sealed - no external seals required. ɀ Quick connect - fixture threads onto the mounting module for easy installation. ɀ One size luminaire for all medium base incandescent lamps through 300W. ɀ One size luminaire for all mogul base incandescent lamps through 500W. ɀ Small compact size - ceiling mount is 133⁄4⍯ long. ɀ Shock absorbing receptacle. ɀ Easy to assemble & relamp. ɀ Silicone gaskets seal out dirt and moisture. ɀ Epoxy powder coat for corrosion resistance. ɀ Same mounting modules as used with the EVM & EVLP series. Standard Materials: ɀ Body, mounting modules and guard - copperfree aluminum ɀ Globe - heat & impact resistant glass ɀ Gaskets - silicone ɀ External hardware - stainless steel ɀ Reflectors - Krydon® fiberglass-reinforced polyester US: 1-866-764-5454 STIBOINFO((CRH:66008com:2L:711)) TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1, Groups C,D Cl. I, Zone 1 & 2, Group IIB Cl. II, Groups E,F,G (Max 150W-Med. base) Cl. III & Simultaneous Presence (Max 150W-Med. base) Marine and Wet Locations ɀ Type 4X; IP66 2L Standard Finishes: EVI series incandescent luminaires are used: ɀ for Type 4X, marine, wet location and hose down environments. ɀ where a consistent light level relatively unaffected by extremes in ambient temperature (-40°C to +65°C) is required. ɀ in areas that require lamps to reach full illumination immediately. ɀ in areas that require lamps to be frequently turned on and off. ɀ indoor & outdoor in locations which are hazardous due to the presence of flammable vapors or gases, ignitible dusts or ignitible fibers & flyings. ɀ where a luminaire is required for tough environmental conditions involving corrosives, water, dust and extreme temperatures. ɀ manufacturing plants, heavy industrial facilities, industrial process facilities such as refineries, chemical, petrochemical, pharmaceutical and platforms. ɀ for lighting of loading docks, tunnels, stairways, storage closets & task lighting. CH0 0 4 F - 5 COLOR: CMYK ɀ Copper free aluminum - Corro-free TM epoxy powder coat ɀ Stainless steel - Natural ɀ Krydon® Reflectors - High reflectance white Electrical Ratings: Sources/Wattages ɀ Medium Base - Maximum 300W (PS25) ɀ Mogul Base - Maximum 500W (PS40) Voltages ɀ Medium Base 120V (250V with suffix /250) ɀ Mogul Base 277V Hub Size ɀ3⁄4⍯ or 1⍯ NPT pendant, ceiling, wall mount ɀ3⁄4⍯ NPT bulkhead mount Certifications and Compliances: NEC & CEC: ɀ Class I, Division 1, Groups C & D ɀ Class I, Zone 1, Group IIB ɀ Class II, Groups E, F & G ɀ Marine Locations, Wet Locations, Enclosure Type 4X, IP66 ɀ UL Listed ɀ cUL Listed (Certified by UL to CSA Standards) NEC: ɀ Class III; Simultaneous Presence UL Standards: ɀ 844 Electric Fixture Hangers for Hazardous Locations ɀ 1598 Luminaires ɀ 1598A Luminaires for Installation on Marine Vessels CSA Standards: ɀ C22.2 No. 137 Options: Description ɀ 250V luminaire for export applications (medium base only) Suffix to be added to Cat. No. /250 Accessories: ɀ Reflectors - See Ordering by Components on page 713. CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 711 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0712-7 Name: 2L-712 2L 100: DATE: JAN 19 2006 Time: 5:45:50 PM Operator: RB EVI Series Explosionproof Incandescent Luminaires Factory Sealed 100-500W Medium and Mogul Base COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1, Groups C,D Cl. I, Zone 1 & 2, Group IIB Cl. II, Groups E,F,G (Max 150W-Med. base) Cl. III & Simultaneous Presence (Max 150W-Med. base) Marine and Wet Locations ɀ Type 4X; IP66 Mounting Style Hub Size EVI301 SERIES Medium Base with EV505 Guard (Max. 300W PS25) Pendant Mount 3⁄4⍯ 1⍯ EVIA2301 EVIA3301 EVIA2501 EVIA3501 Ceiling Mount 3⁄4⍯ 1⍯ EVICX2301 EVICX3301 EVICX2501 EVICX3501 Wall Mount 3⁄4⍯ 1⍯ EVIBX2301 EVIBX3301 EVIBX2501 EVIBX3501 Bulkhead Mount 3⁄4⍯ 1⍯ EVIBH2301 — — — Stanchion Mount 11⁄4⍯ EVIJ4301 EVIJ4501 EVI301 EVI501 Luminaire with Guard Less Mounting Module EVI501 SERIES Mogul Base with EV503 Guard (Max. 500W PS40) Note: Medium base luminaires (EVI301 Series) - For A19 lamps up to 100W, use Leviton socket extension catalog number 2005. Mogul base luminaires (EVI501 Series) - For PS30 medium base lamps, use Cooper Wiring Devices socket adapter catalog number 332. - Available with Lightning Service TM Delivery. See Section G for complete details. 712 STIBOINFO((CRH:66008com:2L:712)) CH0 0 4 F - 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0713-6 Name: 2L-713 100: DATE: JAN 19 2006 Time: 5:45:52 PM Operator: RB EVI Series Explosionproof Incandescent Luminaires COLOR: CMYK TCP: 15001 Ordering By Components Typedriver Name: TS name csm no.: 100 2L Factory Sealed 100-500W Medium and Mogul Base EVI Luminaires are available in components. A complete luminaire consists of: I. Mounting Module II. EVI Luminaire Body and Globe Assembly III. Guard, Reflector I. Mounting Module: Type Pendant Conduit Cat. No. EVMP2 EVMP3 EV22 EV33 EV22 & EV87 EV33 & EV87 EVMJ4 EVIJ2 3⁄4⍯ 1⍯ 3⁄4⍯ 1⍯ 3⁄4⍯ 1⍯ 11⁄4⍯ 3⁄4⍯ Ceiling and Wall Box Wall Bracket Arm Stanchion Bulk Head II. Luminaire Body and Globe Assembly with Guard Type Medium Base Mogul Base Cat. No. EVI301 EVI501 III. Guards and Reflectors Type Guard - Fits EVI301 Series (medium base) Guard - Fits EVI501 Series (mogul base) Dome Reflector - Fits EVI301 Series (medium base) Angle Reflector - Fits EVI301 Series (medium base) Dome Reflector - Fits EVI501 Series (mogul base) Angle Reflector - Fits EVI501 Series (mogul base) Cat. No. EV505 EV503 RD636 RA636 RD739 RA739 - Available with Lightning Service TM Delivery. See Section G for complete details. US: 1-866-764-5454 STIBOINFO((CRH:66008com:2L:713)) CH0 0 4 F - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 713 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0714-5 Name: 2L-714 2L 100: DATE: JAN 19 2006 Time: 5:45:53 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Family Tree Temperature Performance Data EVI Series Explosionproof Incandescent Luminaires Factory Sealed 100-500W Medium and Mogul Base Temperature Performance Data: Type Watts/Lamp EV1301 Medium Base 100W/A21 or A19* 150W/A21 200W/A23 or A25 300W/PS25 EV1501 Mogul Base 200W/PS30* 300W/PS35 500W/PS40 Class I, Div 1 (Class I, Zone 1) Ambient 40°C 55°C 65°C Class II Ambient 40°C Simultaneous Presence Ambient 40°C Supply Wire Temp (°C) Ambient 40°C 55°C 65°C T4 T4 T3 T3 T3C T3C T2D T2D T3C T3C T2C T2C T3C T3C — — T3C T3C — — 90°C 90°C 105°C 105°C 105°C 105°C 125°C 125°C 125°C 125°C 125°C 125°C T4A T4 T3A T4 T3C T3 T4 T3C T3 T3A — — T3A — — 90°C 90°C 105°C 90°C 90°C 125°C 105°C 105°C 125°C * Note: Medium base luminaires (EVI301 Series) - For A19 lamps up to 100W, use Leviton socket extension catalog number 2005. Mogul base luminaires (EVI501 Series) - For PS30 medium base lamps, use Cooper Wiring Devices socket adapter catalog number 332. - Available with Lightning Service TM Delivery. See Section G for complete details. 714 STIBOINFO((CRH:66008com:2L:714)) CH0 0 4 F - 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0715-6 Name: 2L-715 100: DATE: JAN 19 2006 Time: 5:45:54 PM Operator: JB EVI Series Explosionproof Incandescent Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Medium Base Dimensions and Weights 2L Factory Sealed 100-500W Medium and Mogul Base Medium Base EVI Luminaire Dimensions (Inches): Medium Base Net Luminaire Weights (lbs.): EVI301 with guard 11 lbs. Add mounting modules: Pendant Ceiling Wall Bulkhead Stanchion 1.0 lbs 2.0 lbs 4.5 lbs 2.2 lbs 2.5 lbs US: 1-866-764-5454 STIBOINFO((CRH:66008com:2L:715)) CH0 0 4 F - 5 CAN: 1-800-265-0502 Add for Reflectors RD636 (Dome Reflector, Small) RA636 (Angle Reflector, Small) RD739 (Dome Reflector, Small) RA739 (Angle Reflector, Small) Copyright© 2006 Cooper Crouse-Hinds 1.5 lbs 1.0 lbs 2.0 lbs 1.4 lbs 715 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0716-5 Name: 2L-716 2L 100: DATE: JAN 19 2006 Time: 5:45:56 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Mogul Base Dimensions and Weights EVI Series Explosionproof Incandescent Luminaires Factory Sealed 100-500W Medium and Mogul Base Medium Base EVI Luminaire Dimensions (Inches): Mogul Base Net Luminaire Weights (lbs.): EVI501 with guard 24 lbs. Add mounting modules: Pendant Ceiling Wall Bulkhead Stanchion 1.0 lbs 2.0 lbs 4.5 lbs 2.2 lbs 2.5 lbs 716 STIBOINFO((CRH:66008com:2L:716)) CH0 0 4 F - 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Add for Reflectors RD636 (Dome Reflector, Small) RA636 (Angle Reflector, Small) RD739 (Dome Reflector, Small) RA739 (Angle Reflector, Small) Copyright© 2006 Cooper Crouse-Hinds 1.5 lbs 1.0 lbs 2.0 lbs 1.4 lbs Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0717-10 Name: 2L-717 100: DATE: JAN 19 2006 Time: 5:45:57 PM Operator: JB COLOR: CMYK TCP: 15001 Photometric Data EVI Series Explosionproof Incandescent Luminaires Typedriver Name: TS name csm no.: 100 2L Factory Sealed 100-500W Medium and Mogul Base Medium Base Luminaire with Globe and Guard EVICX2301 Lamp: 300W/PS25 Incandescent Medium Base Luminaire with Globe and Dome Reflector (Less Guard) EVICX2300 Lamp: 300W/PS25 Incandescent US: 1-866-764-5454 STIBOINFO((CRH:66008com:2L:717)) CH0 0 4 F - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 717 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0718-9 Name: 2L-718 2L 100: DATE: JAN 19 2006 Time: 5:45:58 PM Operator: JB EVI Series Explosionproof Incandescent Luminaires COLOR: CMYK TCP: 15001 Photometric Data Factory Sealed 100-500W Medium and Mogul Base Medium Base Luminaire with Globe and 30° Angle Reflector (Less Guard) EVICX2300 Lamp: 300W/PS25 Incandescent Mogul Base Luminaire with Globe and Guard EVIA2501 Lamp: 500W/PS40 Incandescent 718 STIBOINFO((CRH:66008com:2L:718)) CH0 0 4 F - 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0719-9 Name: 2L-719 100: DATE: JAN 19 2006 Time: 5:46:00 PM Operator: JB COLOR: CMYK TCP: 15001 Photometric Data EVI Series Explosionproof Incandescent Luminaires Typedriver Name: TS name csm no.: 100 2L Factory Sealed 100-500W Medium and Mogul Base Mogul Base Luminaire with Globe and Dome Reflector (Less Guard) EVIA2500 Lamp: 500W/PS40 Incandescent Mogul Base Luminaire with Globe and Angle Reflector (Less Guard) EVIA2500 Lamp: 500W/PS40 Incandescent US: 1-866-764-5454 STIBOINFO((CRH:66008com:2L:719)) CH0 0 4 F - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 719 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0720-3 Name: 2L-720 2L 100: DATE: JAN 19 2006 Time: 5:46:01 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 and 2, Groups A,B,C,D – Pendant Mount Cl. I, Div. 1 and 2, Groups B,C,D – Ceiling and Bracket Mount Wet Locations NEMA 3,3R EV Incandescent Luminaires Factory Sealed Application: EV292 Series luminaires are used: ɀ to provide incandescent lighting in locations made hazardous due to the presence of hydrogen, gases or vapors of an equivalent hazard, such as manufactured gas. ɀ hydrogen areas of process industries, missile bases where hydrogen fuel is used and gas manufacturing plants. ɀ in areas of lesser hazard than indicated above. ɀ EVA292 pendant mount luminaire is also suitable for use in locations made hazardous due to the presence of acetylene. Features: ɀ Flametight threaded joints – no external seal needed ɀ Easy to assemble and relamp ɀ Shock absorbing receptacle ɀ Gasket seals out dirt and liquids ɀ Positive locking of globe holder ɀ Heat and impact resistant globe ɀ Inner reflector eliminates upward spill light ɀ Lightweight ɀ Corrosion Resistant ɀ Dome and 30° angle reflectors available Pendant style with RD725 dome reflector Max. Lamp Style Size Pendant Standard Materials: Ceiling ɀ Globes – heat and impact resistant glass ɀ Luminaire and bracket arm – copper-free aluminum ɀ Reflectors – Krydon® fiberglass-reinforced polyester ɀ Back box – Feraloy® iron alloy Bracket Standard Finishes: 300 watt, PS-30 (medium base) 300 watt, PS-30 (medium base) 300 watt, PS-30 (medium base) Pendant style with RA725 30° angle reflector Without Hub Reflector Size Cat. # 3⁄4 EVA292 With Guard Pendant style without reflector Dome 30° Angle Reflector Reflector Cat. # Cat. # RD725 RA725 With Guard 3⁄4 EVCX292 RD725 With Guard 3⁄4 EVBX292 Not Applicable Dimensions EVA ɀ Aluminum – epoxy powder coat ɀ Krydon – high reflectance white ɀ Feraloy – electrogalvanized and aluminum acrylic paint EVBX EVCX Size Ranges: ɀ 3⁄4⍯ conduit hub Capacity Ranges: ɀ 300 watt, PS-30 medium base lamps Certifications and Compliances: ɀ NEC/CEC: Class I, Divisions 1 and 2, Groups A,B,C,D – pendant mount Class I, Divisions 1 and 2, Groups B,C,D – ceiling and bracket mount ɀ UL Standard: 844 ɀ CSA Standard: C22.2 No. 137 a b c EVA 87⁄8 163⁄8 147⁄8 EVBX 87⁄8 181⁄8 165⁄8 EVCX 87⁄8 143⁄8 127⁄8 Reflector Diameter Type Dome 16⍯ 30° Angle 16⍯ Temperature Performance Data: Class I Ambient Supply Style UL Temp.°C Wire °C Pendant T3A 25/40 150°C Ceiling T3A 25/40 150°C Bracket T3A 25/40 150°C NOTE: Photometric curves and data are the same as shown for EV Groups C, D series. 720 STIBOINFO((CRH:66008com:2L:720)) CH0 0 2 L - 9 RA725 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds EVCX Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0721-2 Name: 3L-721 100: DATE: JAN 19 2006 Time: 5:46:02 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 High Intensity Discharge (H.I.D.) Lighting Hazardous and Non-Hazardous 3L Description Page No. Application/Selection 722, 723 Champ® Series - Integrally Ballasted Luminaires Accessories Ballast Data (USA) Ballast Data (Canada) 775, 776 677-682 677-682 DMV Series 50 – 250W H.I.D. 743 744-749 750, 751 752, 753 Catalog Listings Dimensions, Weights, Temperature Data Photometric Data LMV Series 35 – 150W H.I.D Catalog Listings Dimensions, Weights, Temperature Data Photometric Data VMV Series 50 – 175W H.I.D Catalog Listings Dimensions, Weights, Temperature Data Photometric Data VMV High Wattage Series 200 – 400W H.I.D. Catalog Listings Dimensions, Weights, Temperature Data Photometric Data N2MV Non-Metallic H.I.D. Catalog Listings Dimensions, Weight, Temperature Data Photometric Data V2PC Photocell US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:721)) CH0 0 0 0 9 F CAN: 1-800-265-0502 735 736-739 740, 741 742 724 725-731 731, 732 733, 734 754 755-760 761, 762 763, 764 765 766-770 771, 772 773, 774 777, 778 Copyright© 2006 Cooper Crouse-Hinds 721 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0722-1 Name: 3L-722 3L DATE: JAN 19 2006 Time: 5:46:03 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 H.I.D. (High Intensity Discharge) Luminaires Enclosed & Gasketed Application and Selection Application: Luminaires included in this section are enclosed and gasketed, designed for use with H.I.D. lamps as follows: ɀ in locations where protection is required from wet, dirty and corrosive atmospheres ɀ where long life lamps provide desirable maintenance cost savings and return on investment through use of fewer luminaires, circuits and ancillary apparatus. ɀ where relamping and maintenance difficulties require long life lamps. Considerations for Selection: Environmental: ɀ What are the hazardous areas classifications (NEC/CEC) of the locations in which the luminaires will be installed? ɀ Must luminaires be suitable for use in marine, hosedown, corrosive applications? Lighting levels required: ɀ What wattage luminaire(s) will provide the desired light level? (See Lighting Selector Guide, Section L to determine number and location of luminaires required) Product Selection: Quick Selector Chart (See specific sections for lamp type and wattage suitability) - Series - - Watts Hazardous Area & Other HPS, MH & MV Lamps Enviromental Suitabilities NEC, CEC, IEC - Ballast Voltages - Standard Voltage Ballasts (60 Hz) VMV Champ 50, 70, 100, 150, 175 Mogul Base NEC & CEC Cl. I, Div. 2 Groups A, B, C, D Cl. II, Groups E, F, G Class III Simultaneous Presence VMV High Wattage Champ 200, 250, 400 Mogul Base LMV Champ Low Profile 35, 50, 70, 100, 150 Medium Base Restricted Breathing (Suffix - S826) CL. I Div. 2 & Zone 2 AEx nR, Ex nR IIC NEC (UL) Multi-tap: 120, 208, 240 & 277 Volt 60 Hz. Dual-tap: 120 & 277 Volt 60 Hz (50W HPS) 120 Volt 60 Hz 480 Volt 60 Hz CEC/CSA (cUL) Tri-tap: 120, 277 & 347 Volt 60 Hz Dual-tap: 120 & 277 Volt 60 Hz (50W HPS) 120 Volt 60 Hz Marine Outdoor & Wet Locations DMV Champ Expanded Class II Suitability N2MV Champ Non Metallic 722 STIBOINFO((CRH:66008com:3L:722)) CH0 0 3 L - 0 50, 70, 100, 150, 175, 250 Mogul Base 50, 70, 100, 150, 175 Mogul Base US: 1-866-764-5454 Type 3, 3R, 4, 4X IP56 to 1P66 IEC Certified for IEC Zone 2 (Suffix - S826TB) Ex nR IIC Optional Voltage Ballasts (50 or 60 Hz) CEC/CSA (cUL) 208 Volt 60 Hz CWI - Isolated 240 Volt 60 Hz CWI - Isolated 480 Volt 60 Hz CWI - Isolated 600 Volt 60 Hz CWI - Isolated IP 56 to IP 66 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds EXPORT 220 Volt 50 Hz 230 Volt 50 Hz 240 Volt 50 Hz Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0723-1 Name: 3L-723 100: DATE: JAN 19 2006 Champ® H.I.D. Luminaires VMV, LMV, DMV, VMV High Wattage & N2MV Series Time: 5:46:04 PM Operator: JB COLOR: CMYK ɀ ɀ ɀ ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. II, Groups E, F, G, Cl. III Simultaneous Presence ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP56 to IP66 3L The Champ family is an extremely versatile industrial lighting system. Five different series of Champ Luminaires embrace a broad range of wattages, lamp sources, compliances, optics, and accessories. Each series is covered in detail on the following pages. General information to help in the proper selection of series and luminaires is shown below. Application: Heavy duty Champ lighting luminaires are used: ɀ in manufacturing plants, refineries, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, offshore, dockside, and harbor installations, and other heavy industrial applications ɀ in areas where ignitible concentrations of flammable gases or vapors will be present only due to abnormal, unusual, or accidental conditions ɀ where combustible dusts are present ɀ in marine applications where water spray and corrosive atmospheres are considerations ɀ in elevated ambient temperatures often found in industrial applications ɀ in installations where moisture, dirt, dust, vibration, corrosion, and rough usage are problems ɀ wherever the damaging effects of water, wind, snow, sleet, hot sun, or any combination of these elements are found. Features: ɀ Cast copper-free aluminum construction (less than 0.4 of 1% copper) and epoxy powder finish provide excellent resistance to corrosion. ɀ Seven mounting arrangements in each series, to suit any lighting layout – pendant, flexible pendant, ceiling, wall bracket, angle stanchion, straight stanchion, and quadmount. ɀ Wide range of light sources and wattages to meet specifiers’ needs: 35, 50, 70, 100, 150, 200, 250 and 400 watt high pressure sodium (HPS); 100, 175, 250, and 400 watt mercury vapor (MV); 70, 100 175, 250, and 400 watt metal halide (MH). ɀ Hinged ballast housings for ease of installation and maintenance; all mounting modules fit all ballast housings. ɀ Wide choice of photometric distributions. Globes available for lamps up through 400 watt HPS, and 250 watt MV and MH. Glass refractors available for all VMV and DMV units; reflector/lens for 200-400 watt VMV units ɀ All luminaires are designed to perform in a 40°C ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65°C. ɀ Superior gasketing seals between the mounting module, housing, and optical assembly for optimum performance in wet and corrosive environments. ɀ Hubs with an integral conduit stop and bushing to help prevent damage to field wiring during installation ɀ Low ambient capability to –40°C ɀ Dome and 30° angle reflectors made of bright white Krydon® fiberglass-reinforced polyester material provide superior reflectivity, with twist-on feature US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:723)) CH0 0 3 L - 1 CAN: 1-800-265-0502 requiring no tools or additional hardware. Will not chip, peel, dent, rust, or corrode ɀ Grounding wire for safety ɀ Ballasts are high power factor (min P.F. 90%) and available in a variety of voltages to meet local area requirements. Copyright© 2006 Cooper Crouse-Hinds 723 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0724-9 Name: 3L-724 3L 100: DATE: JAN 19 2006 Time: 5:46:05 PM Operator: RB 50-175W VMV Series Champ® H.I.D. Luminaires ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (HPS 50W, 70W) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 Application: Options: VMV series Champ luminaires are used: ɀ in manufacturing plants, refineries, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, offshore, dockside, and harbor installations, and other heavy industrial applications ɀ in areas in which ignitible concentrations of flammable gases or vapors will be present only due to abnormal, unusual, or accidental conditions ɀ where combustible dusts are present ɀ in marine applications where water spray and corrosive atmospheres are considerations ɀ in elevated ambient temperatures often found in industrial applications ɀ in installations where moisture, dirt, dust, vibration, corrosion, and rough usage are problems ɀ wherever the damaging effects of water, wind, snow, sleet, hot sun, or any combination of these elements are found The following special options are available from the factory by adding suffix to luminaire Cat. No.: Suffix to be Description added to Cat. No. Features: ɀ Compact, lightweight design is ideal for medium and low mounting heights ɀ Cast copper-free aluminum construction (less than 0.4 of 1% copper) and epoxy powder finish provide excellent resistance to corrosion ɀ Seven mounting arrangements to suit any lighting layout – pendant, flexible pendant, ceiling, wall bracket, angle stanchion, straight stanchion, and quad-mount ɀ Wide range of light sources and wattages to meet specifiers’ needs: 50, 70, 100, and 150 watt high pressure sodium (HPS); 100, and 175 watt mercury vapor (MV); 70, 100, 175 watt metal halide (MH) ɀ Hinged ballast housing for ease of installation and maintenance ɀ Wide choice of photometric distributions. Glass globes, refractors and compact refractors available for all wattage luminaires; plastic refractors (for non-hazardous applications only) for 50-100 watt luminaires ɀ All luminaires are designed to perform in a 40° C ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65°C. ɀ Superior gasketing seals between the mounting module, housing, and optical assembly for optimum performance in wet and corrosive environments ɀ Hubs with an integral conduit stop and bushing to help prevent damage to field wiring during installation ɀ Low ambient capability to (–40°C) ɀ Dome and 30° angle reflectors made of bright white Krydon® material provide superior reflectivity, with twist-on feature requiring no tools or additional hardware. Will not chip, peel, dent, rust, or corrode ɀ Grounding wire for safety ɀ High power factor ballasts (Min P.F. 90%) and available in a variety of voltages to meet local area requirements. ɀ Mogul base porcelain lamp socket 724 STIBOINFO((CRH:66008com:3L:724)) CH0 0 3 L - 2 COLOR: CMYK ɀ Factory Sealed Champs . . . . . . . . . . S865† - Class I Division 2 & Zone 2 - Provides T3 code without conduit or cable seals Restricted breathing/Non-sparking ɀ Restricted Breathing Construction. . . S826† - Class I Division 2 & Zone 2 Suitabilty - Cooler Operating Temperatures (TNumbers) ɀ Certified for IEC Zone 2 . . . . . . . . . . S826TB - Furnished with terminal block, crimp terminals and dedicated voltage ballasts (no MT, DT or TT) Standard Materials: ɀ Ballast housings and mountings – copper free aluminum (less than 0.4 of 1%) ɀ Exterior hardware – stainless steel ɀ Reflectors (dome and angle) – Krydon fiberglass-reinforced polyester material ɀ Globes – heat and impact resistant internally fluted glass ɀ Refractors – glass (50-175 watts); plastic (50-100 watts), for non-hazardous applications. ɀ Guards: globe – copper-free aluminum refractor – stainless steel Standard Finishes: ɀ Copper-free aluminum – epoxy powder coat ɀ Krydon material – high reflectance white ɀ Stainless steel – natural Electrical Ratings: ɀ 120, 208, 240, 277, 347, 480, 600, Multitap刁 (120, 208, 240 and 277) ɀ 50 to 150W HPS; 100 to 175W MV; 70 to 175W MH Certifications and Compliances: ɀ NEC & CEC: - Class I, Division 2, Groups A,B,C,D - HPS 50W, 70W - Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) - Class I Zone 2 ɀ IEC: - Zone 2 Ex nR IIC ɀ UL Standards: - 844, 2279 Hazardous (Classified) Locations - 1598 Luminaires - 1598A Marine Locations ɀ CSA Standards - C22.2 No. 137 ɀ IEC Standards - 60079-15 ɍ VMV Series now available with Champ Induction Lighting System. See Section 5L. US: 1-866-764-5454 CAN: 1-800-265-0502 ɀ Fused – to protect ballast and capacitors against abnormal line conditions . . . . . S658* (Not for use in Canada) ɀ Ballast-Gard TM starter cut-out switch – prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 50-150W LX HPS only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG ɀ Instant restrike – enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage. It has no effect on the warm-up period of cold lamps. Available for use with 50-150W LX HPS only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IR ɀ Quartz auxiliary lighting for use with R2 & R5 large glass refractors only! – comes to full brightness immediately and remains lit until the HID lamp attains 60-70% of full illumination. For non-hazardous locations only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QTZ ɀ Stainless steel insert - top hat with stainless steel threaded insert to attach ballast housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S806 ɀ TEFLON coating on globe for increased shatter protection. . . . . . . . . . . . . . . . . . . . S808 T-Numbers not affected ɀ Factory assembled with H.I.D. lamps installed for additional labor savings. . . . . . FA (Note: BG and IR options cannot be used together. IR and QTZ options cannot be used together.) Accessories: ɀ See pages 775 and 776 for complete listing. TEFLON is a registered trademark of E.I. duPont Co. * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. † For detailed information on Restricted Breathing and Non-Sparking, see page 32 of the Cooper Crouse-Hinds 2005 Code Digest. Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0725-5 Name: 3L-725 DATE: JAN 19 2006 Time: 5:46:06 PM Operator: JB ɀ 50-150W High Pressure Sodium VMV Series Cl. I, Div 2, Groups A, B, C, D Restricted Breathing CL. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Champ® H.I.D. Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ CL. II Groups E, F, G, CL. III & Simultaneous Presence (50W, 70W) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 3L See Notes 1 (to specify voltage), 2 and 3. For guards and other optics see VMV Luminaires – Ordering by Components section. BASIC CATALOG NUMBER Mounting Style Hub Size Lamp With G24 Globe Watts and P21 Guard With G241 Type I Compact Refractor With G245 Type V Compact Refractor With R5 Glass Refractor VMVS2A050GP VMVS3A050GP VMVS2A070GP VMVS3A070GP VMVS2A100GP VMVS3A100GP VMVS2A150GP VMVS3A150GP VMVS2A050G241 VMVS3A050G241 VMVS2A070G241 VMVS3A070G241 VMVS2A100G241 VMVS3A100G241 VMVS2A150G241 VMVS3A150G241 VMVS2A050G245 VMVS3A050G245 VMVS2A070G245 VMVS3A070G245 VMVS2A100G245 VMVS3A100G245 VMVS2A150G245 VMVS3A150G245 VMVS2A050R5 VMVS3A050R5 VMVS2A070R5 VMVS3A070R5 VMVS2A100R5 VMVS3A100R5 VMVS2A150R5 VMVS3A150R5 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 50 3⁄4 50 70 100 150 VMVS2HA050GP VMVS2HA070GP VMVS2HA100GP VMVS2HA150GP VMVS2HA050G241 VMVS2HA070G241 VMVS2HA100G241 VMVS2HA150G241 VMVS2HA050G245 VMVS2HA070G245 VMVS2HA100G245 VMVS2HA150G245 VMVS2HA050R5 VMVS2HA070R5 VMVS2HA100R5 VMVS2HA150R5 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 50 VMVS2C050GP VMVS3C050GP VMVS2C070GP VMVS3C070GP VMVS2C100GP VMVS3C100GP VMVS2C150GP VMVS3C150GP VMVS2C050G241 VMVS3C050G241 VMVS2C070G241 VMVS3C070G241 VMVS2C100G241 VMVS3C100G241 VMVS2C150G241 VMVS3C150G241 VMVS2C050G245 VMVS3C050G245 VMVS2C070G245 VMVS3C070G245 VMVS2C100G245 VMVS3C100G245 VMVS2C150G245 VMVS3C150G245 VMVS2C050R5 VMVS3C050R5 VMVS2C070R5 VMVS3C070R5 VMVS2C100R5 VMVS3C100R5 VMVS2C150R5 VMVS3C150R5 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 50 VMVS2TW050GP VMVS3TW050GP VMVS2TW070GP VMVS3TW070GP VMVS2TW100GP VMVS3TW100GP VMVS2TW150GP VMVS3TW150GP VMVS2TW050G241 VMVS2TW050G245 VMVS2TW050R5 VMVS3TW050G241 VMVS3TW050G245 VMVS3TW050R5 VMVS2TW070G241 VMVS2TW070G245 VMVS2TW070R5 VMVS3TW070G241 VMVS3TW070G245 VMVS3TW070R5 VMVS2TW100G241 VMVS2TW100G245 VMVS2TW100R5 VMVS3TW100G241 VMVS3TW100G245 VMVS3TW100R5 VMVS2TW150G241 VMVS2TW150G245 VMVS2TW150R5 VMVS3TW150G241 VMVS3TW150G245 VMVS3TW150R5 Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2 ° Angle 3⁄4 3⁄4 50 70 100 150 VMVS25Q050GP VMVS25Q070GP VMVS25Q100GP VMVS25Q150GP VMVS25Q050G241 VMVS25Q070G241 VMVS25Q100G241 VMVS25Q150G241 VMVS25Q050G245 VMVS25Q070G245 VMVS25Q100G245 VMVS25Q150G245 VMVS25Q050R5 VMVS25Q070R5 VMVS25Q100R5 VMVS25Q150R5 Stanchion Mount 25° Angle 11⁄2 11⁄2 11⁄2 11⁄2 50 70 100 150 VMVSJ050GP VMVSJ070GP VMVSJ100GP VMVSJ150GP VMVSJ050G241 VMVSJ070G241 VMVSJ100G241 VMVSJ150G241 VMVSJ050G245 VMVSJ070G245 VMVSJ100G245 VMVSJ150G245 VMVSJ050R5 VMVSJ070R5 VMVSJ100R5 VMVSJ150R5 Stanchion Mount Straight 11⁄2 11⁄2 11⁄2 11⁄2 50 70 100 150 VMVSP050GP VMVSP070GP VMVSP100GP VMVSP150GP VMVSP050G241 VMVSP070G241 VMVSP100G241 VMVSP150G241 VMVSP050G245 VMVSP070G245 VMVSP100G245 VMVSP150G245 VMVSP050R5 VMVSP070R5 VMVSP100R5 VMVSP150R5 Pendant Mount Flexible Pendant Mount 3⁄4 3⁄4 3⁄4 Ceiling Mount Thru-Feed Wall Mount Thru-Feed 3⁄4 3⁄4 70 100 150 70 100 150 70 100 150 Standard Voltage Ballasts - 60Hz NEC/UL 1. Voltage Multi Tap Dual Tap Suffix /MT /DT (Multi Tap and Dual Tap ballasts are prewired for 277V) 120V /120 480V /480 CEC/CSA (cUL) Tri Tap /TT Dual Tap /DT Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts EXPORT Voltage 208V CWI 240V CWI 480V CWI 600V CWI 220V 60Hz 220V 50Hz Suffix /208CWI /240CWI /480CWI /600CWI /220 /220 50 2. 150W HPS Luminaires, 55V Lamps is standard; for 100V lamps - Add suffix ‘‘CE’’. 50W HPS Luminaire is dual tap only. 3. Options - Add the required options suffixes from page 724, In Alpha-numeric order. – available with Lightning Service TM delivery. See Section G for complete details. US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:725)) CH0 0 3 L - 3 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 120V /120 230V 50Hz /230 50 240V 50Hz /240 50 725 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0726-2 Name: 3L-726 3L DATE: JAN 19 2006 Time: 5:46:08 PM Operator: RB 150-175W Pulse Start Metal Halide VMV Series Champ® H.I.D. Luminaires COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) Typedriver Name: TS name csm no.: 100 Marine & Wet Locations 3, 3R, 4, 4X; IP66 See Note 1 (to specify voltage). For guards and other optics see VMV Luminaires – Ordering by Components section. BASIC CATALOG NUMBER Mounting Style Pendant Mount Hub Size 3⁄4 1 3⁄4 1 Lamp With G24 Globe Watts and P21 Guard 150 VMVM2A150GP-S828 VMVM3A150GP-S828 175 VMVM2A175GP-S828 VMVM3A175GP-S828 With G245 Type V Compact Refractor VMVM2A150G245-S828 VMVM3A150G245-S828 VMVM2A175G245-S828 VMVM3A175G245-S828 With R5 Glass Refractor VMVM2A150R5-S828 VMVM3A150R5-S828 VMVM2A175R5-S828 VMVM3A175R5-S828 150 175 VMVM2HA150GP-S828 VMVM2HA175GP-S828 VMVM2HA150G245-S828 VMVM2HA175G245-S828 VMVM2HA150R5-S828 VMVM2HA175R5-S828 VMVM2C150GP-S828 VMVM3C150GP-S828 VMVM2C175GP-S828 VMVM3C175GP-S828 VMVM2C150G245-S828 VMVM3C150G245-S828 VMVM2C175G245-S828 VMVM3C175G245-S828 VMVM2C150R5-S828 VMVM3C150R5-S828 VMVM2C175R5-S828 VMVM3C175R5-S828 VMVM2TW150GP-S828 VMVM3TW150GP-S828 VMVM2TW175GP-S828 VMVM3TW175GP-S828 VMVM2TW150G245-S828 VMVM3TW150G245-S828 VMVM2TW175G245-S828 VMVM3TW175G245-S828 VMVM2TW150R5-S828 VMVM3TW150R5-S828 VMVM2TW175R5-S828 VMVM3TW175R5-S828 Flexible Pendant Mount 3⁄4 Ceiling Mount Thru-Feed 3⁄4 1 3⁄4 1 150 3⁄4 1 3⁄4 1 150 Quad-Mount Pendant, Adjustable ThruFeed, 25° Angle, 121⁄2° Angle 3⁄4 3⁄4 150 175 VMVM25Q150GP-S828 VMVM25Q175GP-S828 VMVM25Q150G245-S828 VMVM25Q175G245-S828 VMVM25Q150R5-S828 VMVM25Q175R5-S828 Stanchion Mount 25° Angle 11⁄2 11⁄2 150 175 VMVMJ150GP-S828 VMVMJ175GP-S828 VMVMJ150G245-S828 VMVMJ175G245-S828 VMVMJ150R5-S828 VMVMJ175R5-S828 Stanchion Mount Straight 11⁄2 11⁄2 150 175 VMVMP150GP-S828 VMVMP175GP-S828 VMVMP150G245-S828 VMVMP175G245-S828 VMVMP150R5-S828 VMVMP175R5-S828 Wall Mount Thru-Feed 3⁄4 175 175 1. Voltage Suffix Multi Tap /MT Standard Voltage Ballasts - 60Hz NEC/UL 120V 480V /120 /480 CEC/CSA (cUL) Tri Tap /TT Optional Voltage Ballasts - 50 or 60Hz EXPORT Voltage Suffix 726 STIBOINFO((CRH:66008com:3L:726)) CH0 0 3 L - 5 220V 60Hz /220 US: 1-866-764-5454 220V 50Hz /220 50 CAN: 1-800-265-0502 230V 50Hz /230 50 240V 50Hz /240 50 Copyright© 2006 Cooper Crouse-Hinds 120V /120 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0727-3 Name: 3L-727 DATE: JAN 19 2006 100-175W Metal Halide VMV Series Champ® H.I.D. Luminaires Time: 5:46:09 PM Operator: JB COLOR: CMYK ɀ ɀ ɀ ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) TCP: 15001 Typedriver Name: TS name csm no.: 100 Marine & Wet Locations 3, 3R, 4, 4X; IP66 3L See Note 1 (to specify voltage), 2 and 3. For guards and other optics see VMV Luminaires – Ordering by Components section. BASIC CATALOG NUMBER Mounting Style Pendant Mount Hub Size 3⁄4 1 1 3⁄4 1 Flexible Pendant Mount 3⁄4 Lamp With G24 Globe Watts and P21 Guard 70 VMVM2A070GP VMVM3A070GP 100 VMVM2A100GP VMVM3A100GP 175 VMVM2A175GP VMVM3A175GP With G241 Type I Compact Refractor VMVM2A070G241 VMVM3A070G241 VMVM2A100G241 VMVM3A100G241 VMVM2A175G241 VMVM3A175G241 With G245 Type V Compact Refractor VMVM2A070G245 VMVM3A070G245 VMVM2A100G245 VMVM3A100G245 VMVM2A175G245 VMVM3A175G245 70 100 175 VMVM2HA070GP VMVM2HA070G241 VMVM2HA070G245 VMVM2HA070R5 VMVM2HA100GP VMVM2HA100G241 VMVM2HA100G245 VMVM2HA100R5 VMVM2HA175GP VMVM2HA175G241 VMVM2HA175G245 VMVM2HA175R5 3⁄4 1 3⁄4 1 3⁄4 1 70 VMVM2C070GP VMVM3C070GP VMVM2C100GP VMVM3C100GP VMVM2C175GP VMVM3C175GP VMVM2C070G241 VMVM3C070G241 VMVM2C100G241 VMVM3C100G241 VMVM2C175G241 VMVM3C175G241 3⁄4 1 3⁄4 1 3⁄4 1 70 VMVM2TW070GP VMVM3TW070GP VMVM2TW100GP VMVM3TW100GP VMVM2TW175GP VMVM3TW175GP VMVM2TW070G241 VMVM2TW070G245 VMVM2TW070R5 VMVM3TW070G241 VMVM3TW070G245 VMVM3TW070R5 VMVM2TW100G241 VMVM2TW100G245 VMVM2TW100R5 VMVM3TW100G241 VMVM3TW100G245 VMVM3TW100R5 VMVM2TW175G241 VMVM2TW175G245 VMVM2TW175R5 VMVM3TW175G241 VMVM3TW175G245 VMVM3TW175R5 Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2° Angle 3⁄4 3⁄4 70 100 175 VMVM25Q070GP VMVM25Q100GP VMVM25Q175GP VMVM25Q070G241 VMVM25Q100G241 VMVM25Q175G241 VMVM25Q070G245 VMVM25Q100G245 VMVM25Q175G245 VMVM25Q070R5 VMVM25Q100R5 VMVM25Q175R5 Stanchion Mount 25° Angle 11⁄2 11⁄2 11⁄2 70 100 175 VMVMJ070GP VMVMJ100GP VMVMJ175GP VMVMJ070G241 VMVMJ100G241 VMVMJ175G241 VMVMJ070G245 VMVMJ100G245 VMVMJ175G245 VMVMJ070R5 VMVMJ100R5 VMVMJ175R5 Stanchion Mount Straight 11⁄2 11⁄2 11⁄2 70 100 175 VMVMP070GP VMVMP100GP VMVMP175GP VMVMP070G241 VMVMP100G241 VMVMP175G241 VMVMP070G245 VMVMP100G245 VMVMP175G245 VMVMP070R5 VMVMP100R5 VMVMP175R5 3⁄4 3⁄4 Ceiling Mount Thru-Feed Wall Mount Thru-Feed 3⁄4 100 175 100 175 1. Voltage Suffix Multi Tap /MT Standard Voltage Ballasts - 60Hz NEC/UL 120V 480V /120 /480 VMVM2C070G245 VMVM3C070G245 VMVM2C100G245 VMVM3C100G245 VMVM2C175G245 VMVM3C175G245 CEC/CSA (cUL) Tri Tap /TT Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts Voltage 208V CWI 480V CWI 600V CWI Suffix /208CWI /240CWI /600CWI 2. Options - Add the required options suffixes from page 718, In Alpha-numeric order. 3. 70W Ballast not available in 480V. – available with Lightning Service TM delivery. See Section G for complete details. US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:727)) CH0 0 3 L - 4 With R5 Glass Refractor VMVM2A070R5 VMVM3A070R5 VMVM2A100R5 VMVM3A100R5 VMVM2A175R5 VMVM3A175R5 CAN: 1-800-265-0502 VMVM2C070R5 VMVM3C070R5 VMVM2C100R5 VMVM3C100R5 VMVM2C175R5 VMVM3C175R5 120V /120 EXPORT 220V 60Hz /220 220V 50Hz /220 50 Copyright© 2006 Cooper Crouse-Hinds 230V 50Hz /230 50 240V 50Hz /240 50 727 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0728-3 Name: 3L-728 3L DATE: JAN 19 2006 Time: 5:46:10 PM Operator: JB 100-175W Mercury Vapor VMV Series Champ® H.I.D. Luminaires COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) Typedriver Name: TS name csm no.: 100 Marine & Wet Locations 3, 3R, 4, 4X; IP66 See Notes 1 (to specify voltage) and 2. For guards and other optics see VMV Luminaires – Ordering by Components section. BASIC CATALOG NUMBER Mounting Style Pendant Mount Hub Size 3⁄4 1 3⁄4 1 Lamp With G24 Globe Watts and P21 Guard 100 VMVC2A100GP VMVC3A100GP 175 VMVC2A175GP VMVC3A175GP With G241 Type I Compact Refractor VMVC2A100G241 VMVC3A100G241 VMVC2A175G241 VMVC3A175G241 Flexible Pendant Mount 3⁄4 3⁄4 100 175 VMVC2HA100GP VMVC2HA100G241 VMVC2HA100G245 VMVC2HA100R5 VMVC2HA175GP VMVC2HA175G241 VMVC2HA175G245 VMVC2HA175R5 Ceiling Mount Thru-Feed 3⁄4 100 1 3⁄4 1 175 VMVC2C100GP VMVC3C100GP VMVC2C175GP VMVC3C175GP VMVC2C100G241 VMVC3C100G241 VMVC2C175G241 VMVC3C175G241 VMVC2TW100GP VMVC3TW100GP VMVC2TW175GP VMVC3TW175GP VMVC2TW100G241 VMVC2TW100G245 VMVC2TW100R5 VMVC3TW100G241 VMVC3TW100G245 VMVC3TW100R5 VMVC2TW175G241 VMVC2TW175G245 VMVC2TW175R5 VMVC3TW175G241 VMVC3TW175G245 VMVC3TW175R5 Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2° Angle 3⁄4 3⁄4 100 175 VMVC25Q100GP VMVC25Q175GP VMVC25Q100G241 VMVC25Q175G241 VMVC25Q100G245 VMVC25Q175G245 VMVC25Q100R5 VMVC25Q175R5 Stanchion Mount 25° Angle 11⁄2 11⁄2 100 175 VMVCJ100GP VMVCJ175GP VMVCJ100G241 VMVCJ175G241 VMVCJ100G245 VMVCJ175G245 VMVCJ100R5 VMVCJ175R5 Stanchion Mount Straight 11⁄2 11⁄2 100 175 VMVCP100GP VMVCP175GP VMVCP100G241 VMVCP175G241 VMVCP100G245 VMVCP175G245 VMVCP100R5 VMVCP175R5 Voltage Suffix 175 Multi Tap /MT Standard Voltage Ballasts - 60Hz NEC/UL 120V 480V /120 /480 Optional Voltage Ballasts - 50 or 60Hz EXPORT Voltage 220V 60Hz 220V 50Hz Suffix /220 /220 50 2. Options - Add the required options suffixes from page 724, In Alpha-numeric order. – available with Lightning Service TM delivery. See Section G for complete details. STIBOINFO((CRH:66008com:3L:728)) VMVC2C100R5 VMVC3C100R5 VMVC2C175R5 VMVC3C175R5 100 1. CH0 0 3 L - 4 VMVC2C100G245 VMVC3C100G245 VMVC2C175G245 VMVC3C175G245 With R5 Glass Refractor VMVC2A100R5 VMVC3A100R5 VMVC2A175R5 VMVC3A175R5 3⁄4 1 3⁄4 1 Wall Mount Thru-Feed 728 With G245 Type V Compact Refractor VMVC2A100G245 VMVC3A100G245 VMVC2A175G245 VMVC3A175G245 US: 1-866-764-5454 CAN: 1-800-265-0502 CEC/CSA (cUL) Tri Tap /TT 230V 50Hz /230 50 Copyright© 2006 Cooper Crouse-Hinds 120V /120 240V 50Hz /240 50 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0729-1 Name: 3L-729 100: DATE: JAN 19 2006 Time: 5:47:11 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 VMV Luminaires Ordering by Components 3L VMV luminaires are available in components. A complete luminaire consists of: I. Champ Cover (Mounting Module) II. VMV Ballast Housing - Include voltage and required option(s) III. Optical & Guard components - Globe, Reflector, Refractor, Guard I. Champ Cover (Mounting Module) Type Pendant Flexible Pendant Ceiling Wall Stanchion - 25 Degree Angle Stanchion - Straight Quad-Mount Conduit 3⁄4 1 3⁄4 3⁄4 1 3⁄4 1 11⁄2 11⁄2 3⁄4 Cat. No. APM2 APM3 HPM2 CM2 CM3 TWM2 TWM3 JM5 PM5 QM25 II. Ballast Housings. Complete catalog number must have the voltage suffix (MT shown) and any options suffixes. Lamp Type High Pressure Sodium Metal Halide Mercury Vapor Lamp Watts Cat No. For Globe and Compact Refractor VMVS050/MT VMVS070/MT VMVS100/MT VMVS150/MT LX VMVM070/MT VMVM100/MT VMVM175/MT VMVC100/MT VMVC175/MT 50 70 100 150 70 100 175 100 175 For Large Refractor VMVS050/MT-RM VMVS070/MT-RM VMVS100/MT-RM VMVS150/MT LX-RM VMVM070/MT-RM VMVM100/MT-RM VMVM175/MT-RM VMVC100/MT-RM VMVC175/MT-RM III. Globe, Reflectors, Refractors, Guards Type Globe Globe - Teflon Coated Globe Guard Reflector - Dome Reflector - Angle Cat. No. G24 G24-S808 P21 RD70 RA70 Compact Refractor Type 1 Compact Refractor Type 5 Compact Refractor Guard G241 G245 P241 Large Refractor Type 2 Large Refractor Type 5 Large Refractor Guard R2 R5 P23 Large Plastic Refractor Type 2 Large Plastic Refractor Type 3 Large Plastic Refractor Type 5 PR2 PR3 PR5 US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:729)) CH0 0 3 L - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 729 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0730-2 Name: 3L-730 3L 100: DATE: JAN 19 2006 Time: 5:47:12 PM Operator: JB 50-175W VMV Series COLOR: CMYK TCP: 15001 Family Tree Champ® H.I.D. Luminaires – available with Lightning Service TM delivery. See Section G for complete details. * Plastic refractors are for non-hazardous areas only (50-100W Max.) 730 STIBOINFO((CRH:66008com:3L:730)) CH0 0 3 L - 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0731-36 Name: 3L-731 DATE: JAN 19 2006 Time: 5:47:13 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Temperature Performance Data 50-175W VMV Series 3L ® Champ H.I.D Luminaires LAMP Cat. No. VMVC100-S712 VMVC100 VMVC175 VMVM70 VMVM70 VMVM70 VMVM100 VMVM100-S849 VMVM100 VMVM150 VMVM175 VMVS50 VMVS50 VMVS50 VMVS70 VMVS70 VMVS100 VMVS100 VMVS150 VMVS150 VMVIG055 VMVIG055 Wattage Type 100 100 175 70 70 70 100 100 100 150 175 50 50 50 70 70 100 100 150 150 55 55 MV MV MV MH MH MH MH MH MH MH MH HPS HPS HPS HPS HPS HPS HPS HPS HPS Induction Induction RATED AMBIENT °C CLASS II, DIVISION 1 CLASS I, DIVISION 2 Globe Globe (G24) (G24) w/ w/ or w/o Reflector Refractor Reflector Globe (RA70 or (G241 or (RA70 or (G24) RD70) G245) Group RD70) 40 40 40 40 55 65 40 40 55 40 40 40 55 65 40 55 40 55 40 55 40 55 T2B — T2 T3A T3 T3 T2D T2 T2D T2A T2A T3A T3A T3 T3 T3 T2C T2B T2A T2 T2C T2C T2B — T2 T3A T3 T3 T2D T2 T2D T2A T2A T3A T3A T3 T3 T3 T2C T2B T2A T2 T2C T2C — — T2B T3A T3 T3 T2D T2 T2D T2B T2B T3B T3A T3 T3B T3 T2D T2C T2B T2A — — EFG EFG EFG EFG EFG EFG EFG T4A T4 T4 T3C T3C T3A CLASS I, ZONE 2 Simultaneous Presence Class I, Div. 2 Class II, Div.2 T3A T3 T2D T2C T2B T2A Restricted Breathing Suffix Factory Sealed S826 w/ Suffix S865 Globe (G24) AEx nA nR II T4 T4 T3 T5 T4 T4 T4 T4 T4 T3 T3 T5 T5 T5 T4 T4 T4 T3 T3 T3 T6 T5 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 — — SUPPLY WIRE SUITABLE FOR °C Globe (G24) Refractor (G241 or G245) 75 75 90 90 90 90 90 75 90 90 90 75 75 75 75 90 90 105 90 105 65 65 — 75 85 90 90 90 90 75 90 90 90 65 75 75 65 90 75 90 85 105 — — The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires are listed to UL 844. UL 844 specifies how the temperatures are measured. The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring temperatures. Since NEC® 501.1 states that equipment “...for use in Class I, Zone 0, 1 or 2 locations shall be permitted in Class I, Division 2 locations...” then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They also have the advantage of meeting the more rigorous mechanical tests of UL 844. US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:731)) CH0 0 3 L - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 731 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0732-1 Name: 3L-732 3L DATE: JAN 19 2006 Time: 5:47:14 PM Operator: JB 50-175W VMV Series COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Dimensions and Weights Champ® H.I.D. Luminaires Pendant Mount Ceiling Mount Top View Net Luminaire Weights (lbs.): Luminaire Lamp Watts Series 50 70 100 150 175 Luminaire with Globe, Guards (lbs): 141⁄2 141⁄2 141⁄2 VMVS 131⁄2 VMVC 131⁄4 151⁄2 VMVM 13 131⁄4 151⁄2 Luminaire with Glass Refractor (lbs): 223⁄4 223⁄4 223⁄4 VMVS 213⁄4 VMVC 211⁄2 233⁄4 VMVM 21 211⁄2 233⁄4 Add for mounting modules (lbs): Quad-Mount 31⁄2 Pendant 11⁄4 Flexible Pendant 11⁄2 Angle Stanchion 31⁄2 Ceiling 23⁄4 Straight Stanchion 41⁄2 Wall 41⁄2 Add for reflectors (lbs): 30° Angle 11⁄2 Dome 11⁄2 1 Deduct: ⁄2 lb. for fixture without P21 Guard Quad-Mount Ceiling Mount 25° Angle Stanchion Mount Straight Stanchion Mount Wall Mount Luminairee With: Refractors, Guard Compact Refractor Globe, Guard, Reflectors 732 STIBOINFO((CRH:66008com:3L:732)) CH0 0 3 L - 6 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0733-2 Name: 3L-733 DATE: JAN 19 2006 Time: 5:47:16 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data 50-175W VMV Series 3L ® Champ H.I.D. Luminaires Lamp: 100W/E-231⁄2 high pressure sodium (HPS) Total bare lamp lumens: 9500 To determine number and placement of luminaires see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for high pressure sodium luminaires with 100W/E-231⁄2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages. Consult Cooper Crouse-Hinds for additional photometric data on any Champ Series luminaire. Luminaire with Globe and Dome Reflector Multipliers (for use with candela curve only). ConLuminaire Lamp version Series Watts Factor VMVS 50 0.42 70 0.67 150 1.68 Isofootcandle Chart: Luminaire with Globe and Dome Reflector Luminaire spacing ratio: 1.85 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Eff. Cell 80 70 50 30 10 0 % Reflectance Eff. Cell 80 70 50 30 10 0 Wall 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Wall 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio 1 2 3 .823 .707 .610 .784 .646 .538 .749 .594 .482 .804 .690 .597 .767 .633 .530 .734 .587 .477 .765 .658 .571 .735 .611 .513 .709 .569 .466 .731 .629 .546 .708 .591 .497 .685 .555 .456 .701 .603 .524 .681 .569 .482 .662 .541 .446 .644 .521 .427 Room Cavity Ratio 6 7 8 .412 .366 .326 .334 .290 .253 .278 .239 .201 .403 .359 .320 .329 .285 .250 .274 .235 .200 .386 .344 .307 .320 .277 .244 .271 .231 .197 .371 .329 .296 .312 .272 .237 .267 .227 .195 .357 .319 .285 .304 .266 .232 .263 .224 .192 .245 .207 .176 US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:733)) CH0 0 3 L - 7 4 .529 .451 .391 .517 .445 .388 .494 .431 .381 .473 .419 .375 .454 .406 .367 .348 5 .464 .384 .324 .452 .377 .321 .434 .368 .318 .416 .357 .312 .399 .348 .307 .288 9 .296 .224 .175 .291 .221 .174 .279 .216 .172 .269 .210 .170 .260 .206 .167 .152 10 .258 .187 .142 .252 .187 .142 .244 .182 .140 .235 .178 .137 .227 .173 .135 .120 CAN: 1-800-265-0502 Isofootcandle Chart: Luminaire with Globe and 30° Angle Reflector Isofootcandle charts show illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights. Height (Ft.) Factor Height (Ft.) Factor 6 2.78 14 0.51 8 1.56 16 0.39 12 0.70 Copyright© 2006 Cooper Crouse-Hinds 733 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0734-2 Name: 3L-734 100: DATE: JAN 19 2006 Time: 5:47:17 PM Operator: RB TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data 50-175W VMV Series 3L COLOR: CMYK Champ® H.I.D. Luminaire Lamp: 100W/E-231⁄2 high pressure sodium (HPS) To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. Lamp: 175W/E-28 mercury vapor (MV) To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. Luminaire with I.E.S. Type V Glass Refractor Luminaire with Globe and Dome Reflector NOTE: Photometric data was developed using a 100 watt clear high pressure sodium lamp (9500 lumens). For other clear lamps, use the following conversion factors (multipliers): Luminaire Lamp Conversion Series Watts Factor VMVS 50 0.42 70 0.67 150 1.68 NOTE: Photometric data was developed using a 175 watt diffuse mercury vapor lamp (8600 lumens). For other diffuse lamps, use the following conversion factors (multipliers): Luminaire Lamp Conversion Series Watts Factor VMVC 100 0.49 VMVM 70 0.65 100 0.91 175 1.63 Luminaire spacing ratio: 1.60 Luminaire spacing ratio: 2.0 Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. 80 70 50 30 10 0 % Reflectance Eff. Ceil. 80 70 50 30 10 0 734 STIBOINFO((CRH:66008com:3L:734)) CH0 0 3 L - 8 Wall 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Wall 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio 1 2 3 .848 .709 .597 .796 .631 .509 .750 .566 .439 .818 .682 .576 .770 .611 .493 .726 .552 .428 .759 .632 .533 .720 .574 .464 .685 .521 .407 .706 .586 .493 .675 .538 .435 .645 .495 .386 .658 .544 .457 .632 .504 .408 .608 .469 .366 .581 .441 .340 Room Cavity Ratio 6 7 8 .384 .337 .299 .292 .249 .214 .226 .189 .154 .369 .325 .288 .283 .240 .203 .218 .182 .150 .341 .301 .266 .266 .225 .195 .209 .173 .143 .316 .277 .248 .249 .213 .182 .199 .163 .136 .292 .258 .223 .233 .200 .171 .188 .154 .128 .165 .133 .108 US: 1-866-764-5454 4 .508 .414 .341 .489 .402 .334 .451 .377 .318 .417 .354 .302 .385 .331 .286 .260 5 .437 .343 .271 .419 .331 .264 .389 .312 .253 .359 .291 .240 .331 .274 .227 .203 9 .272 .189 .132 .262 .183 .130 .243 .173 .124 .225 .161 .117 .209 .151 .110 .091 10 .238 .159 .103 .229 .156 .105 .214 .146 .099 .198 .136 .093 .134 .127 .087 .070 CAN: 1-800-265-0502 % Reflectance Eff. Ceil. 80 70 50 30 10 0 % Reflectance Eff. Ceil. 80 70 50 30 10 0 Wall 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Wall 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio 1 2 3 .793 .682 .591 .753 .623 .522 .718 .572 .468 .775 .667 .580 .738 .611 .514 .705 .566 .463 .739 .637 .555 .709 .591 .498 .682 .550 .454 .707 .611 .532 .683 .572 .485 .660 .537 .445 .679 .588 .512 .658 .553 .471 .639 .525 .436 .622 .506 .418 Room Cavity Ratio 6 7 8 .403 .359 .320 .328 .285 .250 .275 .236 .199 .395 .352 .314 .324 .281 .247 .271 .233 .198 .379 .339 .303 .316 .274 .241 .298 .230 .196 .366 .325 .293 .309 .268 .235 .265 .226 .195 .353 .318 .282 .301 .264 .231 .282 .224 .193 .245 .208 .177 Copyright© 2006 Cooper Crouse-Hinds 4 .515 .440 .382 .505 .435 .379 .483 .422 .374 .484 .411 .388 .446 .400 .362 .343 5 .453 .376 .319 .442 .370 .316 .426 .362 .313 .409 .352 .309 .394 .345 .304 .287 9 .291 .221 .174 .286 .219 .174 .276 .215 .172 .266 .209 .170 .257 .208 .168 .153 10 .253 .185 .142 .248 .185 .142 .241 .181 .140 .233 .177 .138 .225 .179 .136 .122 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0735-5 Name: 3L-735 100: DATE: JAN 19 2006 35-150W LMV Series ® Champ H.I.D. Luminaires Medium Base Time: 5:47:18 PM Operator: RB ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (HPS 35, 50W) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 3L Application: Options: LMV series Champ® luminaires are used: ɀ in applications involving low luminaire mounting heights or restricted mounting space or where luminaire weight is a factor ɀ in areas in which ignitible concentrations of flammable gases or vapors will be present only due to abnormal, unusual, or accidental conditions ɀ where combustible dusts are present ɀ where combustible dusts and flammable vapors are present simultaneously ɀ in elevated ambient temperatures often found in industrial applications ɀ in marine applications where water spray and corrosive atmospheres are considerations ɀ wherever the damaging effects of wind, snow, sleet, or hot sun are found ɀ in manufacturing plants, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, offshore or dockside installations, cold storage facilities, parking garages or wherever dust, dirt, water, vibration and rough usage are a problem The following special options are available from the factory by adding suffix to luminaire Cat. No.: Suffix to be Description Added to Cat. No. ɀ Restricted Breathing Construction . . . . S826 - Class I Division 2 & Zone 2 Suitability - Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 . . . . . . . . . . S826TB - Furnished with terminal block, crimp terminals and dedicated voltage ballasts (no MT, DT, or TT) ɀ Fused – to protect ballast and capacitors against abnormal line conditions . . . . . S658* (Not for use in Canada) ɀ Ballast-Gard TM starter cut-out switch – prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 50-100W HPS only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG ɀ Factory assembled with H.I.D. lamps installed for additional labor savings. . . . . . FA ɀ Stainless steel insert - top hat with stainless steel threaded insert to attach ballast housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S806 Features: ɀ Compact, lightweight design is ideal for low mounting heights. ɀ Cast copper-free aluminum construction (less than 0.4 of 1% copper) and epoxy powder finish provide excellent resistance to corrosion. ɀ Seven mounting arrangements to suit any lighting layout – pendant, flexible pendant, ceiling, wall, straight stanchion, angle stanchion, and quad-mount. ɀ Wide range of lamp wattages to meet specifiers needs: 35, 50, 70, 100 and 150 watt (HPS); 70 and 100 watt (MH) medium base lamps. ɀ Hinged ballast housing for ease of installation and maintenance. ɀ All luminaires designed to perform in a 40°C ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65°C. ɀ Superior gasketing seals between the mounting module, housing, and optical assembly for optimum performance in wet and corrosive environments. ɀ Hubs with an integral conduit stop and bushing to help prevent damage to field wiring during installation. ɀ Low ambient capability to –40°C. ɀ Dome and 30° angle reflectors made of bright white Krydon® material provide superior reflectivity, with twist-on feature requiring no tools or additional hardware. Will not chip, peel, dent, rust, or corrode. ɀ Grounding wire for safety. ɀ Medium base lamp sockets. Standard Materials: ɀ Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%) ɀ Exterior hardware – stainless steel ɀ Reflectors (dome and angle) – Krydon fiberglass-reinforced polyester material ɀ Globes – heat and impact resistant, internally fluted glass ɀ Guards – copper-free aluminum Standard Finishes: ɀ Copper-free aluminum – epoxy powder coat ɀ Krydon material – high reflectance white ɀ Stainless steel – natural STIBOINFO((CRH:66008com:3L:735)) Accessories: Electrical Ratings: ɀ See pages 775 and 776 for complete listing ɀ 120 volts, dual-tap (120/277刁), multi-tap刁 ɀ 35, 50, 70, 100, 150 watts HPS ɀ 70 and 100 watts MH * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Certifications and Compliances: ɀ NEC and CEC: - Class I, Division 2, Groups A,B,C,D - HPS 35W, 50W - Class II, Class III & Simultaneous Presence (Class 1, Division 2 and Class II) - Class I Zone 2 ɀ IEC: - Zone 2 Ex nR IIC ɀ UL Standards: - 844, 2279 Hazardous (Classified) Locations - 1598 Luminaires - 1598A Marine Locations ɀ CSA Standards - C22.2 No. 137 ɀ IEC Standards - 60079-15 US: 1-866-764-5454 CH0 0 3 L - 9 COLOR: CMYK CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 735 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0736-2 Name: 3L-736 3L DATE: JAN 19 2006 Time: 5:47:19 PM Operator: RB COLOR: CMYK ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) 35-150W High Pressure Sodium ɀ LMV Series Champ® H.I.D. Luminaires Medium Base TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G; Cl. III & Simultaneous Presence (35W, 50W) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 See Note 1 (to specify voltage), 2 and 3. For guards and other optics see LMV Luminaires - Ordering by Components section. BASIC CATALOG NUMBER Hub Lamp With G54 Globe and Mounting Style Size Watts P50 Guard 3⁄4 Pendant Mount 35 LMVS2A035GP 1 LMVS3A035GP 3⁄4 50 LMVS2A050GP 1 LMVS3A050GP 3⁄4 70 LMVS2A070GP 1 LMVS3A070GP 3⁄4 100 LMVS2A100GP 1 LMVS3A100GP 3⁄4 150 LMVS2A150GP 1 LMVS3A150GP 3⁄4 Flexible Pendant Mount 35 LMVS2HA035GP 3⁄4 50 LMVS2HA050GP 3⁄4 70 LMVS2HA070GP 3⁄4 100 LMVS2HA100GP 3⁄4 150 LMVS2HA150GP 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 3⁄4 3⁄4 3⁄4 3⁄4 35 35 50 70 100 150 LMVS2C035GP LMVS3C035GP LMVS2C050GP LMVS3C050GP LMVS2C070GP LMVS3C070GP LMVS2C100GP LMVS3C100GP LMVS2C150GP LMVS3C150GP LMVS2TW035GP LMVS3TW035GP LMVS2TW050GP LMVS3TW050GP LMVS2TW070GP LMVS3TW070GP LMVS2TW100GP LMVS3TW100GP LMVS2TW150GP LMVS3TW150GP LMVS25Q035GP LMVS25Q050GP LMVS25Q070GP LMVS25Q100GP LMVS25Q150GP Stanchion Mount 25° Angle 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 35 50 70 100 150 LMVSJ035GP LMVSJ050GP LMVSJ070GP LMVSJ100GP LMVSJ150GP Stanchion Mount Straight 11⁄2 11⁄2 11⁄2 11⁄2 11⁄2 35 50 70 100 150 LMVSP035GP LMVSP050GP LMVSP070GP LMVSP100GP LMVSP150GP Ceiling Mount Thru-Feed Wall Mount Thru-Feed Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2° Angle Voltage Suffix STIBOINFO((CRH:66008com:3L:736)) CH0 3 L - 1 0 70 100 150 35 50 70 100 150 Standard Voltage Ballasts - 60Hz NEC/UL 1. 736 50 Multi Tap /MT Dual Tap /DT 120V /120 480V /480 CEC/CSA (cUL) Tri Tap /TT Dual Tap /DT 2. 150W HPS Luminaires, 55V Lamps is Standard . 50W HPS luminaire is dual-tap only. 3. Options - Add the Required Options Suffixes from page 735, In Alpha-numeric Order – available with Lightning Service TMdelivery. See Section G for complete details US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 120V /120 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0737-2 Name: 3L-737 DATE: JAN 19 2006 70-100W Metal Halide LMV Series Champ® H.I.D. Luminaires Medium Base Time: 5:47:21 PM Operator: RB COLOR: CMYK ɀ ɀ ɀ ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) TCP: 15001 Typedriver Name: TS name csm no.: 100 Marine & Wet Locations 3, 3R, 4, 4X; IP66 3L See Note 1 (to specify voltage), 2 and 3. For guards and other optics see LMV Luminaires - Ordering by Components section. BASIC CATALOG NUMBER Hub Lamp With G54 Globe and Mounting Style Size Watts P50 Guard 3⁄4 Pendant Mount 70 LMVM2A070GP 1 LMVM3A070GP 3⁄4 100 LMVM2A100GP 1 LMVM3A100GP Flexible Pendant Mount 3⁄4 70 100 LMVM2HA070GP LMVM2HA100GP 3⁄4 1 3⁄4 1 70 LMVM2C070GP LMVM3C070GP LMVM2C100GP LMVM3C100GP 3⁄4 1 3⁄4 1 70 Stanchion Mount 25° Angle 11⁄2 11⁄2 70 100 LMVMJ070GP LMVMJ100GP Stanchion Mount Straight 11⁄2 11⁄2 70 100 LMVMP070GP LMVMP100GP 3⁄4 Ceiling Mount Thru-Feed Wall Mount Thru-Feed 100 100 LMVM2TW070GP LMVM3TW070GP LMVM2TW100GP LMVM3TW100GP Standard Voltage Ballasts - 60Hz NEC/UL 1. Voltage Suffix Multi Tap /MT 120V /120 480V /480 CEC/CSA (cUL) Tri Tap /TT 120V /120 2. Options - Add the Required Options Suffixes from page 735 in Alpha-numeric Order 3. 70W Ballast not available in 480V. US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:737)) CH0 3 L - 1 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 737 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0738-1 Name: 3L-738 3L 100: DATE: JAN 19 2006 Time: 5:47:22 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 LMV Luminaires Ordering by Components LMV luminaires are available in components A complete luminaire consists of: I. Champ Cover (mounting module) II. LMV Ballast Housing - Include voltage and required option(s) III. Globe, Guard, Reflector I. Champ Cover (Mounting Module): Type Pendant Flexible Pendant Ceiling Wall Stanchion - 25 Degree Angle Stanchion - Straight Quad-Mount Conduit 3⁄4 1 3⁄4 3⁄4 1 3⁄4 1 11⁄2 11⁄2 3⁄4 Cat. No. APM2 APM3 HPM2 CM2 CM3 TWM2 TWM3 JM5 PM5 QM25 II. Ballast Housings: Complete catalog number must have the voltage suffix (MT shown) and any options suffixes. Lamp Type High Pressure Sodium Metal Halide Lamp Watts 35 50 70 100 150 70 100 Catalog Number LMVS035/MT LMVS050/MT LMVS070/MT LMVS100/MT LMVS150/MT LX LMVM070/MT LMVM100/MT III. Globe, Guards and Reflectors: Type Globe Globe Guard Globe Reflector-Dome Globe Reflector-Angle 738 STIBOINFO((CRH:66008com:3L:738)) CH0 3 L - 1 5 Catalog Number G54 P50 RD636 RA636 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0739-1 Name: 3L-739 100: DATE: JAN 19 2006 Time: 5:47:23 PM Operator: JB 35-150W LMV Series COLOR: CMYK TCP: 15001 Family Tree Typedriver Name: TS name csm no.: 100 3L ® Champ H.I.D. Luminaires – available with Lightning Service TM delivery. See Section G for complete details. US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:739)) CH0 3 L - 1 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 739 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0740-16 Name: 3L-740 100: DATE: JAN 19 2006 Time: 5:47:24 PM Operator: GK COLOR: CMYK Typedriver Name: TS name csm no.: 100 Temperature Performance Data 35-150W LMV Series 3L TCP: 15001 Champ® H.I.D Luminaires RATED AMBIENT °C LAMP Cat. No. LMVS35 LMVS35 LMVS35 LMVS50 LMVS50 LMVS50 LMVS70 LMVS70 LMVS100 LMVS100 LMVM70 LMVM70 LMVM100 LMVM150 Wattage Type 35 35 35 50 50 50 70 70 100 100 70 70 100 150 HPS HPS HPS HPS HPS HPS HPS HPS HPS HPS MH MH MH HPS 40 55 65 40 55 65 40 55 40 50 40 55 40 40 CLASS I, DIVISION 2 Globe (G54) w/ or w/o Reflector (RA636 or RD636)* T3A T3 T3 T2D T2C T2C T2B T2B T2 — T2B T2B — T1 350°C CLASS II, DIVISION 1 CLASS I, ZONE 2 Group Globe (G54) w/ or w/o Reflector (RA636 or RD636) Simultaneous Presence Class I, Div. 2 Class II, Div. 1 Restricted Breathing Suffix S826 w/ Globe (G54) Factory Sealed Suffix S865 AEx nA nR II Supply Wire Suitable for °C EFG EFG EFG EFG — — — — — — — — — — T4A T4 T3C T3C — — — — — — — — — — T2D T2C T2C T2B — — — — — — — — — — T6 T5 T4 T5 T4 T4 T4 T4 T4 T3 T4 T4 T3 — T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 — N/A 75 85 N/A 75 85 75 85 85 90 75 85 85 85 The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires are listed to UL 844. UL 844 specifies how the temperatures are measured. The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring temperatures. Since NEC® 501.1 states that equipment “...for use in Class I, Zone 0, 1 or 2 locations shall be permitted in Class I, Division 2 locations...” then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They also have the advantage of meeting the more rigorous mechanical tests of UL 844. 740 STIBOINFO((CRH:66008com:3L:740)) CH0 3 L - 1 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0741-1 Name: 3L-741 DATE: JAN 19 2006 Time: 5:47:25 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Dimensions and Weights 35-150W LMV Series 3L ® Champ H.I.D. Luminaires Dimensions Pendant Mount Top View Wall Mount Ceiling Mount Quad-Mount Luminaire with Globe, Guard, Reflectors Straight Stanchion Mount 25° Angle Stanchion Mount Luminaire Net Weights: Luminaire Lamp Series Watts LMVS LMVM 35 50 70 100 150 70 100 Luminaire with Globe, Guard (lbs.) 71⁄4 73⁄4 81⁄4 83⁄4 91⁄4 9 9 Add for mounting modules (lbs.) Wall Pendant 11⁄4 41⁄2 Flexible Pendant 11⁄2 Angle Stanchion 31⁄2 Ceiling 23⁄4 Straight Stanchion 41⁄2 QuadMount 31⁄2 US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:741)) CH0 3 L - 1 2 CAN: 1-800-265-0502 Add for reflectors (lbs.): Dome 1.0 30° Angle 1.0 Deduct for luminaire without guard (lbs.): P50 Guard 1⁄2 Copyright© 2006 Cooper Crouse-Hinds 741 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0742-2 Name: 3L-742 100: DATE: JAN 19 2006 Time: 5:47:26 PM Operator: RB TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data 35-150W LMV Series 3L COLOR: CMYK Champ® H.I.D. Luminaires Lamp: 100W/E-17 high pressure sodium (HPS) Total bare lamp lumens: 9500 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for high pressure sodium luminaires with 100W/E-17 clear lamps. Use conversion factors (multipliers) shown below for other lamp types and wattages. Consult Cooper Crouse-Hinds for additional photometric data on any Champ Series luminaire. Luminaire with Globe and Dome Reflector Multipliers (for use with candlepower curves only). ConLuminaire Lamp version Series Watts Factors LMVS 35 0.24 50 0.42 70 0.67 150 1.68 Isofootcandle Chart: Luminaire with Globe and Dome Reflector Luminaire spacing ratio: 2.0 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Eff. Cell 80 70 50 30 10 0 % Reflectance Eff. Cell 80 70 50 30 10 0 742 STIBOINFO((CRH:66008com:3L:742)) CH0 3 L - 1 3 Wall 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio 1 2 3 .722 .628 .545 .691 .579 .487 .663 .537 .441 .705 .613 .534 .676 .568 .479 .650 .531 .436 .671 .585 .511 .647 .548 .464 .627 .514 .426 .641 .560 .489 .623 .529 .450 .605 .501 .416 .614 .537 .470 .598 .510 .436 .584 .488 .407 .568 .471 .391 4 .473 .408 .358 .463 .403 .355 .442 .390 .349 .424 .379 .342 .407 .367 .335 .319 5 .413 .346 .296 .403 .340 .293 .387 .332 .289 .371 .322 .284 .356 .341 .279 .263 Wall 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio 6 7 8 .366 .324 .288 .300 .259 .225 .253 .215 .180 .358 .318 .282 .295 .255 .223 .249 .212 .179 .343 .305 .271 .288 .248 .217 .246 .209 .177 .330 .292 .261 .280 .243 .210 .242 .205 .175 .317 .282 .251 .272 .237 .206 .238 .202 .172 .223 .187 .158 9 .261 .199 .156 .256 .196 .156 .246 .192 .154 .237 .186 .152 .228 .182 .149 .136 10 .226 .165 .127 .221 .165 .126 .214 .161 .124 .206 .157 .122 .199 .152 .120 .107 US: 1-866-764-5454 CAN: 1-800-265-0502 Isofootcandle Chart: Luminaire with Globe and 30° Angle Reflector Isofootcandle charts show illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights. Height (Ft.) Factor Height (Ft.) Factor 6 2.78 14 0.51 8 1.56 16 0.39 12 0.70 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0743-9 Name: 3L-743 100: DATE: JAN 19 2006 50-250W DMV Series ® Champ H.I.D. Lighting Luminaires Enclosed & Gasketed Time: 5:47:27 PM Operator: RB ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (175W max) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 3L Application: Options: DMV series Champ luminaires are used: ɀ in applications made hazardous by the presence of combustible dusts ɀ in areas in which ignitible concentrations of flammable gases or vapors will be present only due to abnormal, unusual, or accidental conditions ɀ in marine applications where water spray and corrosive atmospheres are considerations ɀ in areas where combustible dusts and flammable vapors are present simultaneously ɀ in elevated ambient temperatures often found in industrial applications ɀ in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems ɀ wherever the damaging effects of wind, snow, sleet, or hot sun are found ɀ in grain handling, storage and processing plants, coal preparation plants, coal conveying areas, food processing plants, manufacturing plants, refineries, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, offshore, dockside, and harbor installations, and other heavy industrial applications The following special options are available from the factory by adding suffix to luminaire Cat. No.: Suffix to be Description Added to Cat. No. ɀ Restricted Breathing Construction. . . . S826 - Class I Division 2 & Zone 2 Suitabilty - Cooler Operating Temperatures (T-Numbers) Features: ɀ Cast copper-free aluminum construction (less than 0.4 of 1% copper) and epoxy powder finish provide excellent resistance to corrosion. ɀ Seven mounting arrangements to suit any lighting layout – pendant, flexible pendant, ceiling, wall bracket, angle stanchion, straight stanchion, and quad-mount. ɀ Wide range of light sources and wattages to meet specifiers needs: 50, 70, 100, 150 watt high pressure sodium (HPS); 100, 175, 250 watt mercury vapor (MV); 70, 100, 175, 250 watt metal halide. ɀ Hinged ballast housing for ease of installation and maintenance. ɀ All luminaires designed to perform in a 40° C ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65° C. ɀ Superior gasketing seals between the mounting module, housing, and optical assembly for optimum performance in wet and corrosive environments. ɀ Hubs with an integral conduit stop and bushing to help prevent damage to field wiring during installation. ɀ Low ambient capability to (–40 ° C.) ɀ Dome and 30° angle reflectors made of bright white Krydon® material provide superior reflectivity, with twist-on feature requiring no tools or additional hardware. Will not chip, peel, dent, rust, or corrode. ɀ Mogul base porcelain lamp socket. ɀ Stainless steel open bottom guard permits direct access to the globe for easy relamping. DMV Series * Now available with Champ Induction Lighting System. See Section 5L. ɀ Grounding wire for safety. ɀ Ballasts available in voltages of 120, 208, 240, 277, 347, 480, 600 and multi-tap.刁 Standard Materials: ɀ Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1% copper) ɀ Guard and exterior hardware – stainless steel ɀ Reflectors (dome and angle) – Krydon fiberglass-reinforced polyester material ɀ Globes – heat and impact resistant, internally fluted glass Standard Finishes: ɀ Copper-free aluminum – epoxy powder coat ɀ Krydon material – high reflectance white ɀ Stainless steel – natural Electrical Ratings: ɀ 120, multi-tap刁 (120, 208, 240 and 277), tri-tap (120, 208, 347) 208, 240, 277, 347, 480, 600 volts ɀ 50-250W HPS; 100-250W† MV; 70-250W† MH Certifications and Compliances: ɀ NEC & CEC: - Class I, Division 2, Groups A,B,C,D - 175W max - Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) - Class I Zone 2 ɀ IEC: - Zone 2 Ex nR IIC ɀ UL Standards: - 844, 2279 Hazardous (Classified) Locations - 1598 Luminaires - 1598A Marine Locations ɀ CSA Standards - C22.2 No. 137 ɀ IEC Standards - 60079-15 US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:743)) CH0 3 L - 1 4 COLOR: CMYK CAN: 1-800-265-0502 ɀ Restricted Breathing/Non-Sparking. . . S865 - Class I Division 2 & Zone 2 - Provides T3 code without conduit or cable seals ɀ Certified for IEC Zone 2 . . . . . . . . . . S826TB - Furnished with terminal block, crimp terminals and dedicated voltage ballasts (no MT, DT or TT) ɀ Fused – to protect ballast and capacitors against abnormal line conditions . . . . . . . . . . . . . . . . . . . . . . . . . S658* (Not for use in Canada) ɀ Ballast-Gard TM starter cut-out switch – prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 50-150W LX HPS only . . . . . . . . . . BG ɀ Instant restrike – enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage. It has no effect on the warm-up period of cold lamps. Available for use with 50-150W LX HPS only . . . . . . . . . . . . . . . . . . . . . . . . . . . IR ɀ Quartz auxiliary lighting – comes to full brightness immediately and remains lit until the HID lamp attains 60-70% of full illumination. For nonhazardous locations only. (Note: QTZ lamp not included; use 100W single ended lamp – Q100DC, Q100CL/DC, or 100Q/CL/DC) Consult factory for top-hat limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . QTZ ɀ Factory assembled with H.I.D. lamps installed for additional labor savings. . . . . . FA ɀ TEFLON® coated globe-for additional protection against breakage. For use with 50-150W HPS, 70-175W MH and 100-175W MV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S808 NOTE: Some T-numbers (operating temperatures) change. See ‘‘Temperature Performance Data’’ section. ɀ Stainless steel insert - top hat with stainless steel threaded insert to attach ballast housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S806 (Note: BG and IR options cannot be used together. IR and QTZ options cannot be used together.) Accessories: ɀ See pages 775 and 776 for complete listing. ɀ See page 749 for family tree. ɍTEFLON is a registered trademark of E.I. duPont Co. * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Copyright© 2006 Cooper Crouse-Hinds 743 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0744-2 Name: 3L-744 3L DATE: JAN 19 2006 Time: 5:47:28 PM Operator: RB COLOR: CMYK ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) 50-150W High Pressure Sodium ɀ DMV Series Champ® H.I.D. Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G; Cl. III & Simultaneous Presence ɀ Marine & Wet Locations ɀ 3,3R, 4,4X; IP66 See notes 1 (to specify voltage) 2 and 3. For guards and other optics see DMV Luminaires - Ordering by Components section. BASIC CATALOG NUMBER Mounting Hub Lamp With G303 Globe With GR305 Glass Style Size Watts and P33 Guard Refractor 3⁄4 Pendant Mount 50 DMVS2A050GP DMVS2A050GR305 1 DMVS3A050GP DMVS3A050GR305 3⁄4 70 DMVS2A070GP DMVS2A070GR305 1 DMVS3A070GP DMVS3A070GR305 3⁄4 100 DMVS2A100GP DMVS2A100GR305 1 DMVS3A100GP DMVS3A100GR305 3⁄4 150 DMVS2A150GP DMVS2A150GR305 1 DMVS3A150GP DMVS3A150GR305 3⁄4 Flexible Pendant Mount 50 70 100 150 DMVS2HA050GP DMVS2HA070GP DMVS2HA100GP DMVS2HA150GP DMVS2HA050GR305 DMVS2HA070GR305 DMVS2HA100GR305 DMVS2HA150GR305 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 50 DMVS2C050GP DMVS3C050GP DMVS2C070GP DMVS3C070GP DMVS2C100GP DMVS3C100GP DMVS2C150GP DMVS3C150GP DMVS2C050GR305 DMVS3C050GR305 DMVS2C070GR305 DMVS3C070GR305 DMVS2C100GR305 DMVS3C100GR305 DMVS2C150GR305 DMVS3C150GR305 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 50 DMVS2TW050GP DMVS3TW050GP DMVS2TW070GP DMVS3TW070GP DMVS2TW100GP DMVS3TW100GP DMVS2TW150GP DMVS3TW150GP DMVS2TW050GR305 DMVS3TW050GR305 DMVS2TW070GR305 DMVS3TW070GR305 DMVS2TW100GR305 DMVS3TW100GR305 DMVS2TW150GR305 DMVS3TW150GR305 Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2° Angle 3⁄4 3⁄4 50 70 100 150 DMVS25Q050GP DMVS25Q070GP DMVS25Q100GP DMVS25Q150GP DMVS25Q050GR305 DMVS25Q070GR305 DMVS25Q100GR305 DMVS25Q150GR305 Stanchion Mount 25° Angle 11⁄2 11⁄2 11⁄2 11⁄2 50 70 100 150 DMVSJ050GP DMVSJ070GP DMVSJ100GP DMVSJ150GP DMVSJ050GR305 DMVSJ070GR305 DMVSJ100GR305 DMVSJ150GR305 Stanchion Mount Straight 11⁄2 11⁄2 11⁄2 11⁄2 50 70 100 150 DMVSP050GP DMVSP070GP DMVSP100GP DMVSP150GP DMVSP050GR305 DMVSP070GR305 DMVSP100GR305 DMVSP150GR305 3⁄4 3⁄4 3⁄4 Ceiling Mount Thru-Feed Wall Mount Thru-Feed 3⁄4 3⁄4 1. Voltage Suffix Multi Tap /MT 70 100 150 70 100 150 Standard Voltage Ballasts - 60Hz NEC/UL Dual Tap 120V 480V /DT /120 /480 Tri Tap /TT CEC/CSA (cUL) Dual Tap /DT Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts EXPORT Voltage 208V CWI 240V CWI 480V CWI 600V CWI 220V 60Hz 220V 50Hz Suffix /208CWI /240CWI /480CWI /600CWI /220 /220 50 2. 150W HPS Luminaires, 55V Lamps is Standard, for 100V lamps - Add suffix ‘‘CE’’. 50W HPS luminaire is dual-tap only. 3. Options - Add the Required Options Suffixes from page 743, In Alpha-numeric order. – available with Lightning Service TM delivery. See Section G for details. 744 STIBOINFO((CRH:66008com:3L:744)) CH0 3 L - 2 2 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 120V /120 230V 50Hz /230 50 240V 50Hz /240 50 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0745-3 Name: 3L-745 DATE: JAN 19 2006 150-250W Pulse Start Metal Halide DMV Series Champ® H.I.D. Luminaires Time: 5:47:30 PM Operator: RB ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (175W max) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 3L See Notes 1 (to specify voltage) and 2. For Guards and other optics see DMV Luminaires - Ordering by Components Section BASIC CATALOG NUMBER 150 175 200 With G303 Globe With GR305 Glass and P33 Guard Refractor Cat. No. Cat. No. DMVM2A150GP-S828 DMVM2A150GR305-S828 DMVM3A150GP-S828 DMVM3A150GR305-S828 DMVM2A175GP-S828 DMVM2A175GR305-S828 DMVM3A175GP-S828 DMVM3A175GR305-S828 DMVM2A200GP-S828 DMVM2A200GR305-S828 DMVM3A200GP-S828 DMVM3A200GR305-S828 (Use Ceiling Mount) - Ceiling Mount has pendant conduit hub (Use Ceiling Mount) DMVM2HA150GP-S828 DMVM2HA150GR305-S828 DMVM2HA175GP-S828 DMVM2HA175GR305-S828 DMVM2HA200GP-S828 DMVM2HA200GR305-S828 3⁄4 250 (Use Ceiling Mount) 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 150 DMVM2C150GP-S828 DMVM3C150GP-S828 DMVM2C175GP-S828 DMVM3C175GP-S828 DMVM2C200GP-S828 DMVM3C200GP-S828 DMVM2C250GP-S828 DMVM3C250GP-S828 DMVM2C150GR305-S828 DMVM3C150GR305-S828 DMVM2C175GR305-S828 DMVM3C175GR305-S828 DMVM2C200GR305-S828 DMVM3C200GR305-S828 DMVM2C250GR305-S828 DMVM3C250GR305-S828 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 150 DMVM2TW150GP-S828 DMVM3TW150GP-S828 DMVM2TW175GP-S828 DMVM3TW175GP-S828 DMVM2TW200GP-S828 DMVM3TW200GP-S828 DMVM2TW250GP-S828 DMVM3TW250GP-S828 DMVM2TW150GR305-S828 DMVM3TW150GR305-S828 DMVM2TW175GR305-S828 DMVM3TW175GR305-S828 DMVM2TW200GR305-S828 DMVM3TW200GR305-S828 DMVM2TW250GR305-S828 DMVM3TW250GR305-S828 Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2° Angle 3⁄4 3⁄4 150 175 200 250 DMVM25Q150GP-S828 DMVM25Q175GP-S828 DMVM25Q200GP-S828 DMVM25Q250GP-S828 DMVM25Q150GR305-S828 DMVM25Q175GR305-S828 DMVM25Q200GR305-S828 DMVM25Q250GR305-S828 Stanchion Mount 25° Angle 11⁄2 11⁄2 11⁄2 11⁄2 150 175 200 250 DMVMJ150GP-S828 DMVMJ175GP-S828 DMVMJ200GP-S828 DMVMJ250GP-S828 DMVMJ150GR305-S828 DMVMJ175GR305-S828 DMVMJ200GR305-S828 DMVMJ250GR305-S828 Stanchion Mount Straight 11⁄2 11⁄2 11⁄2 11⁄2 150 175 200 250 DMVMP150GP-S828 DMVMP175GP-S828 DMVMP200GP-S828 DMVMP250GP-S828 DMVMP150GR305-S828 DMVMP175GR305-S828 DMVMP200GR305-S828 DMVMP250GR305-S828 Mounting Style Pendant Mount Flexible Pendant Mount Ceiling Mount Thru-Feed Wall Mount Thru-Feed Hub Size 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 3⁄4 3⁄4 Lamp Watts 150 175 200 250 175 200 250 175 200 250 3⁄4 3⁄4 1. Voltage Suffix Multi Tap /MT - Ceiling Mount has pendant conduit hub Standard Voltage Ballasts - 60Hz NEC/UL 120V 480V /120 /480 CEC/CSA (cUL) Tri Tap /TT 120V /120 Optional Voltage Ballasts - 50 or 60Hz EXPORT Voltage 220V 60Hz 220V 50Hz Suffix /220 /220 50 2. Options - Add the Required Options Suffixes for page 743 in Alpha-numeric Order US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:745)) CH0 3 L - 2 4 CAN: 1-800-265-0502 230V 50Hz /230 50 Copyright© 2006 Cooper Crouse-Hinds 240V 50Hz /240 50 745 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0746-2 Name: 3L-746 3L DATE: JAN 19 2006 Time: 5:48:34 PM Operator: RB COLOR: CMYK TCP: 15001 ɀ ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) 70-250W Metal Halide Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (175W max) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 ɀ DMV Series Champ® H.I.D. Luminaires Typedriver Name: TS name csm no.: 100 See Note 1 (to specify voltage), 2 and 3. For Guards and other optics see DMV Luminaires - Ordering by Components Section BASIC CATALOG NUMBER 70 100 175 With G303 Globe and P33 Guard Cat. No. DMVM2A070GP DMVM3A070GP DMVM2A100GP DMVM3A100GP DMVM2A175GP DMVM3A175GP (Use Ceiling Mount) (Use Ceiling Mount) DMVM2HA070GP DMVM2HA100GP DMVM2HA175GP 3⁄4 250 (Use Ceiling Mount) 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 70 DMVM2C070GP DMVM3C070GP DMVM2C100GP DMVM3C100GP DMVM2C175GP DMVM3C175GP DMVM2C250GP DMVM3C250GP DMVM2C070GR305 DMVM3C070GR305 DMVM2C100GR305 DMVM3C100GR305 DMVM2C175GR305 DMVM3C175GR305 DMVM2C250GR305 DMVM3C250GR305 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 70 DMVM2TW070GP DMVM3TW070GP DMVM2TW100GP DMVM3TW100GP DMVM2TW175GP DMVM3TW175GP DMVM2TW250GP DMVM3TW250GP DMVM2TW070GR305 DMVM3TW070GR305 DMVM2TW100GR305 DMVM3TW100GR305 DMVM2TW175GR305 DMVM3TW175GR305 DMVM2TW250GR305 DMVM3TW250GR305 Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2° Angle 3⁄4 3⁄4 70 100 175 250 DMVM25Q070GP DMVM25Q100GP DMVM25Q175GP DMVM25Q250GP DMVM25Q070GR305 DMVM25Q100GR305 DMVM25Q175GR305 DMVM25Q250GR305 Stanchion Mount 25° Angle 11⁄2 11⁄2 11⁄2 11⁄2 70 100 175 250 DMVMJ070GP DMVMJ100GP DMVMJ175GP DMVMJ250GP DMVMJ070GR305 DMVMJ100GR305 DMVMJ175GR305 DMVMJ250GR305 Stanchion Mount Straight 11⁄2 11⁄2 11⁄2 11⁄2 70 100 175 250 DMVMP070GP DMVMP100GP DMVMP175GP DMVMP250GP DMVMP070GR305 DMVMP100GR305 DMVMP175GR305 DMVMP250GR305 Mounting Style Pendant Mount Hub Size 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 3⁄4 3⁄4 Flexible Pendant Mount Ceiling Mount Thru-Feed Wall Mount Thru-Feed Lamp Watts 70 100 175 250 100 175 250 100 175 250 3⁄4 3⁄4 1. Voltage Suffix Multi Tap /MT With GR305 Glass Refractor Cat. No. DMVM2A070GR305 DMVM3A070GR305 DMVM2A100GR305 DMVM3A100GR305 DMVM2A175GR305 DMVM3A175GR305 - Ceiling Mount has pendant conduit hub DMVM2HA070GR305 DMVM2HA100GR305 DMVM2HA175GR305 - Ceiling Mount has pendant conduit hub Standard Voltage Ballasts - 60Hz NEC/UL 120V 480V /120 /480 CEC/CSA (cUL) Tri Tap /TT Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts – 175W and 250W MH only Voltage Suffix 746 STIBOINFO((CRH:66008com:3L:746)) CH0 3 L - 2 4 2. 3. 208V CWI /208CWI 240V CWI /240CWI 600V CWI /600CWI EXPORT 220V 60Hz /220 220V 50Hz /220 50 70W Ballast not available in 480V Options - Add the required options suffixes from page 743, in Alpha-numeric order. US: 1-866-764-5454 CAN: 1-800-265-0502 120V /120 Copyright© 2006 Cooper Crouse-Hinds 230V 50Hz /230 50 240V 50Hz /240 50 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0747-3 Name: 3L-747 DATE: JAN 19 2006 Time: 5:48:36 PM Operator: JB ɀ 100-250W Mercury Vapor Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ DMV Series Champ® H.I.D. Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (175W max) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 3L See Note 1 (to specify voltage) and 2. For Guards and other optics see DMV Luminaires - Ordering by Components Section BASIC CATALOG NUMBER With G303 Globe and P33 Guard Cat. No. DMVC2A100GP DMVC3A100GP DMVC2A175GP DMVC3A175GP DMVC2A250GP DMVC3A250GP With GR305 Glass Refractor Cat. No. DMVC2A100GR305 DMVC3A100GR305 DMVC2A175GR305 DMVC3A175GR305 DMVC2A250GR305 DMVC3A250GR305 100 175 250 DMVC2HA100GP DMVC2HA175GP DMVC2HA250GP DMVC2HA100GR305 DMVC2HA175GR305 DMVC2HA250GR305 3⁄4 1 3⁄4 1 3⁄4 1 100 DMVC2C100GP DMVC3C100GP DMVC2C175GP DMVC3C175GP DMVC2C250GP DMVC3C250GP DMVC2C100GR305 DMVC3C100GR305 DMVC2C175GR305 DMVC3C175GR305 DMVC2C250GR305 DMVC3C250GR305 3⁄4 1 3⁄4 1 3⁄4 1 100 DMVC2TW100GP DMVC3TW100GP DMVC2TW175GP DMVC3TW175GP DMVC2TW250GP DMVC3TW250GP DMVC2TW100GR305 DMVC3TW100GR305 DMVC2TW175GR305 DMVC3TW175GR305 DMVC2TW250GR305 DMVC3TW250GR305 Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2° Angle 3⁄4 3⁄4 100 175 250 DMVC25Q100GP DMVC25Q175GP DMVC25Q250GP DMVC25Q100GR305 DMVC25Q175GR305 DMVC25Q250GR305 Stanchion Mount 25° Angle 11⁄2 11⁄2 11⁄2 100 175 250 DMVCJ100GP DMVCJ175GP DMVCJ250GP DMVCJ100GR305 DMVCJ175GR305 DMVCJ250GR305 Stanchion Mount Straight 11⁄2 11⁄2 11⁄2 100 175 250 DMVCP100GP DMVCP175GP DMVCP250GP DMVCP100GR305 DMVCP175GR305 DMVCP250GR305 Mounting Style Pendant Mount Flexible Pendant Mount Hub Size 3⁄4 1 3⁄4 1 3⁄4 1 Lamp Watts 100 175 250 3⁄4 3⁄4 3⁄4 Ceiling Mount ThruFeed Wall Mount Thru-Feed 175 250 175 250 3⁄4 1. Voltage Suffix Multi Tap /MT Voltage Suffix 2. STIBOINFO((CRH:66008com:3L:747)) CEC/CSA (cUL) Tri Tap /TT Optional Voltage Ballasts - 50 or 60Hz EXPORT 220V 60Hz 220V 50Hz 230V 50Hz /220 /220 50 /230 50 120V /120 240V 50Hz /240 50 Options - Add the required options suffixes from page 743, in Alpha-numeric order. US: 1-866-764-5454 CH0 3 L - 1 6 Standard Voltage Ballasts - 60Hz NEC/UL 120V 480V /120 /480 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 747 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0748-1 Name: 3L-748 3L 100: DATE: JAN 19 2006 Time: 5:48:38 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 DMV Luminaires Ordering by Components DMV luminaires are available in components A complete luminaire consists of: I. Champ Cover (mounting module) II. DMV Ballast Housing - Include voltage and required option(s) III. Globe, Refractor, Guard, Reflector I. Champ Cover (Mounting Module): Type Pendant Flexible Pendant Ceiling Wall Stanchion - 25 Degree Angle Stanchion - Straight Quad-Mount Conduit 3⁄4 1 3⁄4 3⁄4 1 3⁄4 1 11⁄2 11⁄2 3⁄4 Cat. No. APM2 APM3 HPM2 CM2 CM3 TWM2 TWM3 JM5 PM5 QM25 II. Ballast Housings. Complete catalog number must have the voltage suffix (MT shown) and any options suffixes. Lamp Type High Pressure Sodium Metal Halide Mercury Vapor Lamp Watts 50 70 100 150 250 70 100 175 250 100 175 250 Catalog Number DMVS050/MT DMVS070/MT DMVS100/MT DMVS150/MT LX DMVS250/MT DMVM070/MT DMVM100/MT DMVM175/MT DMVM250/MT DMVC100/MT DMVC175/MT DMVC250/MT III. Globe, Refractors, Reflectors, Guards Type Globe Globe - Teflon Coated Globe Guard Reflector-Dome Reflector-Angle Refractor - Type 2 Refractor - Type 5 Large Plastic Refractor Type 2 Large Plastic Refractor Type 3 Large Plastic Refractor Type 5 Refractor Guard High Bay Reflector/Lens 748 STIBOINFO((CRH:66008com:3L:748)) CH0 3 L - 2 4 Catalog Number G303 G303-S808 P33 RD739 RA739 GR302 GR305 PGR302 PGR303 PGR305 P23 GRD4 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0749-2 Name: 3L-749 100: DATE: JAN 19 2006 Time: 5:48:38 PM Operator: JB 50-250W DMV Series COLOR: CMYK TCP: 15001 Family Tree Typedriver Name: TS name csm no.: 100 3L ® Champ H.I.D. Luminaires – available with Lightning Service TM delivery. See Section G for complete details. * Plastic refractors are for non-hazardous areas only (50-100W Max.) US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:749)) CH0 3 L - 2 4 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 749 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0750-24 Name: 3L-750 DATE: JAN 19 2006 Time: 5:48:40 PM Operator: RB TCP: 15001 Typedriver Name: TS name csm no.: 100 Temperature Performance Data 50-250W DMV Series 3L COLOR: CMYK Champ® H.I.D Luminaires RATED AMBIENT °C LAMP Cat. No. DMVS50 DMVS50 DMVS50 DMVS70 DMVS70 DMVS70 DMVS100 DMVS100 DMVS100 DMVS150 DMVS150 DMVS150 DMVC100 DMVC100 DMVC100 DMVC175 DMVC175 DMVC175 DMVC250 DMVC250 DMVM70 DMVM70 DMVM70 DMVM100 DMVM100 DMVM100 DMVM175 DMVM175 DMVM175 DMVM200 DMVM200 DMVM250 DMVM250 DMVF26 DMVF39 DMVF52 DMVF64 DMVIG85 DMVIG165 Wattage Globe (G303) w/ or w/o Reflector Refractor (RA739 or (GR302 or RD739)* GR305) Type 50 HPS 50 HPS 50 HPS 70 HPS 70 HPS 70 HPS 100 HPS 100 HPS 100 HPS 150 HPS 150 HPS 150 HPS 100 MV 100 MV 100 MV 175 MV 175 MV 175 MV 250 MV 250 MV 70 MH 70 MH 70 MH 100 MH 100 MH 100 MH 175 MH 175 MH 175 MH 200 MH 200 MH 250 MH 250 MH 2/13 (26) CF 3/13 (39) CF 2/26 (52) CF 2/32 (64) CF 85 Induction 165 Induction 40 55 65 40 55 65 40 55 65 40 55 65 40 55 65 40 55 65 40 55 40 55 65 40 55 65 40 55 65 40 55 40 55 40 40 40 40 40 40 CLASS II, DIVISION 1 CLASS I, DIVISION 2 T3A T3 T3 T3A T3 T3 T2D T2C T2C T2B T2B T2A T3 T2D T2C T2A T2A T2A T1 T1 T3C* T3B* T3A* T3* T3* T2D* T2B* T2A* T2A* T2 T1 (325) T2 T1 (325) T3A T3A T3 T3 T3 T3 T3A T3 T3 T3A T3 T3 T2D T2C T2C T2B T2B T2B T3 T2D T2C T2 T2 T2 — — T3C T3C T3A T3A T3A T2D T2 T2 T2 — — — — — — — — — — Group EFG EFG EFG EFG EFG EFG EFG EFG — EFG EFG EFG EFG EFG EFG EFG EFG — — — — — — — — — EFG EFG — — — — — EFG EFG EFG EFG — — Refractor Globe (G303) (G302 or with G305) or Reflector Globe (RA739 or (G303)** RD739) T6 T5 T4A T6 T5 T4A T5 T4A — T3C T4A — T4A T4 T3C T3B T4 — — — — — — — — — T3C T4 — — — — — T6 T6 T6 T6 — T2D T6 T5 T4A T6 T5 T4A T5 T4A — T3C — — T4A T4 T3C T3C — — — — — — — — — — T3C — — — — — — T6 T6 — — — — CLASS I, ZONE 2 Simultaneous Presence Restricted Globe (G303) Factory Class I, Div.2 Breathing with Sealed Class II, Div.1 Suffix Reflector Suffix (with G303 S826 w/ (RA739 or S865 AEx Globe only) Globe (G303) RD739 nA nR II T3A T3 T3 T3A T3 T3 T3D T2C — T2A — — T2B T2B T2B T2A — — — — — — — — — — T2A — — — — — — — — — — — T2D T6 T5 T5 T6 T5 T5 T6 T5 T4 T5 T4 — T5 T4 T4 T4 T4 T3 T3 T3 T6 T5 T5 T5 T5 T4 T4 T4 T3 T4 T3 T4 T3 T6 T6 T6 T6 T6 T5 T6 T5 T5 T6 T5 T5 T6 T5 T4 T5 T4 — T5 T4 T4 T4 T4 T3 T3 T3 T6 T5 T5 T5 T5 T4 T4 T4 T3 T4 T3 T4 T3 T6 T6 T6 T6 T6 — T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 T3 — — Supply Wire Suitable for °C 75 85 90 75 85 90 75 85 90 75 85 85 75 85 90 75 85 90 85 110 60 75 85 60 75 85 85 85 90 75 90 75 90 60 60 60 60 60 75 The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires are listed to UL 844. UL 844 specifies how the temperatures are measured. The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring temperatures. Since NEC® 501.1 states that equipment “...for use in Class I, Zone 0, 1 or 2 locations shall be permitted in Class I, Division 2 locations...” then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They also have the advantage of meeting the more rigorous mechanical tests of UL 844. * All DMVM 175W and below MH luminaires provided with Catalog number G303-S808 have a T2A T-code. ** For use with refractor only when this table indicates by means of a T-code that the refractor is suitable for use with Class I, Division 2 luminaires. 750 STIBOINFO((CRH:66008com:3L:750)) CH0 3 L - 2 4 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0751-2 Name: 3L-751 100: DATE: JAN 19 2006 Time: 5:48:41 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 50-250W DMV Series 3L ® Champ H.I.D. Luminaires Dimensions and Weights DMV Dimensions Net Luminaire Weights (lbs.) Pendant Mount Quad-Mount 25° Angle Stanchion Mount Straight Stanchion Mount Top View Luminaire with Luminaire with Luminaire Lamp Globe, Guard Lamp Globe, Guard Series Watts (lbs.) Watts (lbs.) DMVS 50 23 70 231⁄16 100 241⁄16 150 261⁄8 DMVC 100 211⁄16 175 221⁄4 250 24 DMVM 70 21 100 211⁄16 175 221⁄4 250 24 Add for mounting modules (lbs.): Pendant 11⁄4 Flexible Pendant 11⁄2 Ceiling 23⁄4 Wall 41⁄2 Quad Mount 31⁄2 Angle Stanchion 31⁄2 Straight Stanchion 41⁄2 Add for reflectors (lbs.): Dome 11⁄4 30° Angle 13⁄4 Deduct: 1 lb. for luminaire without P33 Guard. Add: 51⁄2 lbs. for luminaire with GR305 refractor. Ceiling Mount Wall Mount Luminaire with Globe, Guard, Reflectors US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:751)) CH0 3 L - 1 8 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 751 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0752-2 Name: 3L-752 3L 100: DATE: JAN 19 2006 Time: 5:48:42 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data 50-250W DMV Series Champ® H.I.D. Luminaires Lamp: 150W/E-23-1/2 clear high pressure sodium (HPS) Total bare lamp lumens: 16000 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for high pressure sodium luminaires with 150W/E-231⁄2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages. Consult Cooper Crouse-Hinds for additional photometric data on any Champ series luminaires. Luminaire with Globe and Dome Reflector Multipliers: (for use with candela curves only). Luminaire Lamp Series Watts DMVS 50 70 100 Isofootcandle Chart: Luminaire with Globe and Dome Reflector Conversion Factor 0.25 0.40 0.59 Luminaire spacing ratio: 1.90 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .759 .643 .551 80 30 .719 .582 .480 10 .683 .530 .424 50 .740 .627 .538 70 30 .703 .570 .471 10 .669 .523 .418 50 .703 .595 .512 50 30 .672 .548 .455 10 .645 .506 .408 50 .669 .567 .488 30 30 .646 .528 .439 10 .622 .492 .399 50 .640 .541 .466 10 30 .619 .508 .424 10 .600 .479 .389 0 0 .582 .459 .370 4 .476 .400 .342 .465 .394 .338 .442 .381 .332 .422 .368 .325 .403 .356 .318 .299 5 .418 .340 .283 .406 .334 .280 .388 .324 .276 .370 .314 .270 .354 .305 .265 .247 % Reflectance Eff. Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 9 .267 .198 .151 .262 .195 .151 .250 .190 .148 .240 .184 .146 .231 .180 .143 .128 10 .231 .164 .121 .226 .164 .121 .218 .159 .119 .209 .154 .116 .201 .150 .114 .100 752 STIBOINFO((CRH:66008com:3L:752)) CH0 3 L - 1 9 Room Cavity Ratio 6 7 8 .371 .330 .294 .296 .257 .224 .243 .208 .174 .362 .323 .288 .291 .252 .221 .238 .204 .173 .345 .309 .275 .283 .244 .215 .235 .201 .170 .331 .294 .265 .275 .239 .208 .231 .196 .168 .317 .284 .253 .266 .233 .203 .227 .193 .165 .210 .177 .149 US: 1-866-764-5454 CAN: 1-800-265-0502 Isofootcandle Chart: Luminaire with Globe and 30° Angle Reflector Isofootcandle charts show illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights. Height (Ft.) Factor Height (Ft.) Factor 8 1.56 16 .391 12 .694 20 .250 14 .510 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0753-2 Name: 3L-753 100: DATE: JAN 19 2006 Time: 5:48:43 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data 50-250W DMV Series 3L ® Champ H.I.D. Luminaires Lamp: 175W/E-28 coated mercury vapor (MV) Total bare lamp lumens: 8600 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for mercury vapor luminaires with 175W/E-28 diffuse lamps. Use conversion factors (multipliers) shown below for other diffuse lamp types and wattages. Consult Cooper CrouseHinds for additional photometric data on any Champ series luminaire. Luminaire with Globe and Dome Reflector Multipliers: (for use with candela curves only). Luminaire Lamp Series Watts DMVC 100 250 DMVM 175 250 Isofootcandle Chart: Luminaire with Globe and Dome Reflector Conversion Factor 0.49 1.41 1.63 2.38 Luminaire spacing ratio: 1.7 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .723 .619 .536 80 30 .684 .561 .470 10 .649 .512 .417 50 .705 .604 .524 70 30 .668 .549 .461 10 .635 .505 .412 50 .668 .572 .498 50 30 .638 .528 .445 10 .611 .488 .401 50 .635 .545 .474 30 30 .611 .508 .429 10 .588 .474 .391 50 .606 .519 .453 10 30 .585 .488 .414 10 .566 .460 .381 0 0 .549 .442 .363 4 .467 .396 .342 .456 .390 .338 .434 .377 .331 .414 .365 .324 .395 .352 .317 .299 5 .412 .340 .286 .401 .334 .283 .384 .324 .279 .366 .314 .273 .350 .305 .268 .251 % Reflectance Eff. Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 9 .269 .204 .160 .263 .201 .159 .252 .196 .157 .243 .190 .154 .233 .186 .151 .138 10 .234 .172 .131 .229 .171 .131 .221 .166 .128 .212 .162 .126 .205 .157 .123 .110 Room Cavity Ratio 6 7 8 .368 .329 .294 .298 .261 .229 .248 .215 .182 .359 .322 .289 .293 .256 .226 .244 .211 .181 .343 .308 .276 .284 .248 .220 .240 .207 .178 .329 .294 .266 .276 .243 .213 .236 .203 .176 .315 .284 .255 .268 .236 .208 .231 .200 .173 .216 .184 .158 US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:753)) CH0 3 L - 2 0 CAN: 1-800-265-0502 Isofootcandle Chart: Luminaire with Globe and 30° Angle Reflector Isofootcandle charts show illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights. Height (Ft.) Factor Height (Ft.) Factor 8 1.56 16 .391 12 .694 20 .250 14 .510 Copyright© 2006 Cooper Crouse-Hinds 753 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0754-7 Name: 3L-754 3L 100: DATE: JAN 19 2006 Time: 5:48:44 PM Operator: RB 200-400W VMV High Wattage Series Champ® H.I.D. Luminaires Application: Features: ɀ Cast copper-free aluminum construction (less than 0.4 of 1% copper) and epoxy powder finish provide excellent resistance to corrosion ɀ Six mounting arrangements to suit any lighting layout – pendant, ceiling, wall bracket, angle stanchion, straight stanchion and quad-mount. ɀ Wide range of light sources and wattages to meet specifiers needs: 200, 250, 400 watt high pressure sodium (HPS); 250 and 400 watt mercury vapor (MV); 250 and 400 watt metal halide (MH) ɀ Hinged ballast housing for ease of installation and maintenance ɀ Wide choice of photometric distributions. Glass globes, glass refractors, and reflector/ lens are available ɀ All luminaires designed to perform in a 40° C ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65°C. ɀ Superior gasketing seals between the mounting module, housing, and optical assembly for optimum performance in wet and corrosive environments. ɀ Hubs with integral conduit stop and bushing to help prevent damage to field wiring during installation ɀ Low ambient capability to (–40°C) ɀ Dome and 30° angle reflectors made of bright white Krydon® material and etched Alzak® high bay reflectors provide superior reflectivity ɀ Grounding wire for safety ɀ High power factor ballasts (Min. P. F. 90%) are available in a variety of voltages to meet local area requirements. ɀ Mogul base lamp socket STIBOINFO((CRH:66008com:3L:754)) CH0 3 L - 2 1 ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (with Glass Refractor) ɀ Marine (with Globe or Glass Refractor) & Wet Locations ɀ 3, 3R, 4, 4X; IP66 Standard Materials: VMV high wattage series Champ luminaires are used: ɀ in manufacturing plants, refineries, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, and other heavy industrial applications ɀ in applications involving medium and high mounting heights ɀ in applications where energy efficient, high lumen output is required ɀ in areas in which ignitible concentrations of flammable gases or vapors will be present only due to abnormal, unusual, or accidental conditions ɀ in marine applications where water spray and corrosive atmospheres are considerations ɀ in elevated ambient temperatures often found in industrial applications ɀ in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems ɀ wherever the damaging effects of water, wind, snow, sleet, hot sun, or any combination of these elements, are problems 754 COLOR: CMYK ɀ Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%) ɀ Exterior hardware and guards – stainless steel ɀ Reflectors (dome and angle) – Krydon fiberglass-reinforced polyester material ɀ Globes – heat and impact resistant internally fluted glass ɀ Refractors – glass ɀ Reflector lens – spun Alzak aluminum, tempered glass, stainless steel door frame Standard Finishes: ɀ Copper-free aluminum – epoxy powder coat ɀ Alzak aluminum – natural ɀ Stainless steel – natural ɀ Krydon material – high reflectance white Pendant mount with globe and guard Certifications and Compliances: ɀ NEC and CEC: - Class I, Division 2, Groups A, B, C, D - with Glass Refractor - Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) - Class 1 Zone 2 ɀ IEC: - Zone 2 Ex nR IIC ɀ UL Standards: - 844, 2279 Hazardous (Classified) Locations - 1598 Luminaires - 1598A Marine Locations ɀ CSA Standards - C22.2 No. 137 ɀ IEC Standards - 60079-15 Ceiling mount with etched Alzak reflector and tempered glass lens Options: The following special options are available from the factory by adding suffix to luminaire Cat. No. Suffix to be Description Added to Cat. No. ɀ Restricted Breathting Construction . . S826‡ - Class I Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 . . . . . . . . . S826TB‡ - Furnished with terminal block crimp terminals and dedicated voltage ballasts (no MT, DT, or TT) ɀ Fused – to protect ballast and capacitors against abnormal line conditions . . . . S658†* ɀ Quartz auxilliary lighting – comes to full brightness immediately and remains lit until the HID lamp attains 60-70% of full illumination. For non-hazardous locations only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QTZ (NOTE: Quartz lamp not included use 100W single ended lamp – Q100DC, Q100CL/DC, or 100Q/CL/DC). Consult factory for top-hat limitations. ɀ Ballast-gard TM starter cutout switch – prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 200-400W HPS only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG ɀ Factory assembled with H.I.D. lamps installed for additional labor savings. . . . . . FA ɀ Top hat with stainless steel threaded insert to attach ballast housing. . . . . . . . . . . . . . S806 US: 1-866-764-5454 CAN: 1-800-265-0502 Ceiling mount with glass refractor Electrical Ratings: ɀ 120 to 600 volts and multi-tap刁 ɀ 200, 250, 400W HPS; 250, 400W MV and MH Accessories: ɀ See pages 775 to 776 for complete listing. 刁Alzak is a registered trademark of ALCOA. † Not for use in Canada. ‡Suffix S826 and S826TB cannot be used with GRD4 Reflector/Lens * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0755-3 Name: 3L-755 DATE: JAN 19 2006 Time: 5:48:45 PM Operator: JB COLOR: CMYK ɀ 200-400W High Pressure Sodium Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ VMV High Wattage Series Champ® H.I.D. Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (with Glass Refractor) ɀ Marine (with Globe or Glass Refractor) & Wet Locations ɀ 3, 3R, 4, 4X; IP56 to IP66 3L See notes 1 (to specify voltage) and 2. For guards and other optics see VMV Luminaires - Ordering by Components section. BASIC CATALOG NUMBER Mounting Style Pendant Mount (Rigid or Flexible) Hub Size 3⁄4 1 3⁄4 1 3⁄4 1 Lamp Watts 200 250 400 With G303 Globe and P33 Guard VMVS2A200GP VMVS3A200GP VMVS2A250GP VMVS3A250GP VMVS2A400GP VMVS3A400GP With GR305 Glass Refractor VMVS2A200GR305 VMVS3A200GR305 VMVS2A250GR305 VMVS3A250GR305 VMVS2A400GR305 VMVS3A400GR305 With GRD4 Reflector/Lens2 VMVS2A200GRD4 VMVS3A200GRD4 VMVS2A250GRD4 VMVS3A250GRD4 VMVS2A400GRD4 VMVS3A400GRD4 VMVS2C200GP VMVS3C200GP VMVS2C250GP VMVS3C250GP VMVS2C400GP VMVS3C400GP VMVS2C200GR305 VMVS3C200GR305 VMVS2C250GR305 VMVS3C250GR305 VMVS2C400GR305 VMVS3C400GR305 VMVS2C200GRD4 VMVS3C200GRD4 VMVS2C250GRD4 VMVS3C250GRD4 VMVS2C400GRD4 VMVS3C400GRD4 VMVS2TW200GP VMVS3TW200GP VMVS2TW250GP VMVS3TW250GP VMVS2TW400GP VMVS3TW400GP VMVS2TW200GR305 VMVS3TW200GR305 VMVS2TW250GR305 VMVS3TW250GR305 VMVS2TW400GR305 VMVS3TW400GR305 3⁄4 1 3⁄4 1 3⁄4 1 200 3⁄4 1 3⁄4 1 3⁄4 1 200 Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2° Angle 3⁄4 3⁄4 200 250 400 VMVS25Q200GP VMVS25Q250GP VMVS25Q400GP VMVS25Q200GR305 VMVS25Q250GR305 VMVS25Q400GR305 VMVS25Q200GRD4 VMVS25Q250GRD4 VMVS25Q400GRD4 Stanchion Mount 25° Angle 11⁄2 11⁄2 11⁄2 200 250 400 VMVSJ200GP VMVSJ250GP VMVSJ400GP VMVSJ200GR305 VMVSJ250GR305 VMVSJ400GR305 VMVSJ200GRD4 VMVSJ250GRD4 VMVSJ400GRD4 Stanchion Mount Straight 11⁄2 11⁄2 11⁄2 200 250 400 VMVSP200GP VMVSP250GP VMVSP400GP VMVSP200GR305 VMVSP250GR305 VMVSP400GR305 Ceiling Mount Thru-Feed Wall Mount Thru-Feed 250 400 250 400 3⁄4 1. Voltage Suffix Multi Tap /MT Standard Voltage Ballasts - 60Hz NEC/UL 120V 480V /120 /480 CEC/CSA (cUL) Tri Tap /TT Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts Voltage 208V CWI 240V CWI 480V CWI 600V CWI 220V 60Hz Suffix /208CWI /240CWI /480CWI /600CWI /220 2. Options - Add the Required Options Suffixes from page 754, In Alpha-numeric Order. TM – available with Lightning Service delivery. See Section G for details US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:755)) CH0 3 L - 2 2 CAN: 1-800-265-0502 120V /120 EXPORT 220V 50Hz /220 50 Copyright© 2006 Cooper Crouse-Hinds 230V 50Hz /230 50 240V 50Hz /240 50 755 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0756-3 Name: 3L-756 3L DATE: JAN 19 2006 Time: 5:48:47 PM Operator: JB 250-400W Pulse Start Metal Halide VMV High Wattage Series Champ® H.I.D. Luminaires COLOR: CMYK ɀ TCP: 15001 Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (with Glass Refractor) ɀ Marine (with Globe or Glass Refractor) & Wet Locations ɀ 3, 3R, 4, 4X; IP56 to IP66 See Note 1 (to specify voltage) and 2. For guards and other optics, see VMV luminaires - ordering by components section BASIC CATALOG NUMBER Mounting Style Pendant Mount (Rigid or Flexible) Hub Size 3⁄4 1 3⁄4 1 3⁄4 1 Lamp With G303 Globe Watts and P33 Guard 250 VMVM2A250GP-S828 VMVM3A250GP-S828 320 With GR305 Glass Refractor VMVM2A250GR305-S828 VMVM3A250GR305-S828 VMVM2A320GR305-S828 VMVM3A320GR305-S828 VMVM2A400GR305-S828 VMVM3A400GR305-S828 With GRD4 Reflector/Lens VMVM2A250GRD4-S828 VMVM3A250GRD4-S828 VMVM2A320GRD4-S828 VMVM3A320GRD4-S828 VMVM2A400GRD4-S828 VMVM3A400GRD4-S828 VMVM2C250GP-S828 VMVM3C250GP-S828 VMVM2C250GR305-S828 VMVM3C250GR305-S828 VMVM2C320GR305-S828 VMVM3C320GR305-S828 VMVM2C400GR305-S828 VMVM3C400GR305-S828 VMVM2C250GRD4-S828 VMVM3C250GRD4-S828 VMVM2C320GRD4-S828 VMVM3C320GRD4-S828 VMVM2C400GRD4-S828 VMVM3C400GRD4-S828 VMVM2C250GP-S828 VMVM3C250GP-S828 VMVM2TW250GR305-S828 VMVM3TW250GR305-S828 VMVM2TW320GR305-S828 VMVM3TW320GR305-S828 VMVM2TW400GR305-S828 VMVM3TW400GR305-S828 VMVM2TW250GRD4-S828 VMVM3TW250GRD4-S828 VMVM2TW320GRD4-S828 VMVM3TW320GRD4-S828 VMVM2TW400GRD4-S828 VMVM3TW400GRD4-S828 400 3⁄4 1 3⁄4 1 3⁄4 1 250 3⁄4 1 3⁄4 1 3⁄4 1 250 Quad-Mount Pendant, Adjustable ThruFeed, 25° Angle, 121⁄2° Angle 3⁄4 3⁄4 250 320 400 VMVM25Q250GP-S828 VMVM25Q250GR305-S828 VMVM25Q320GR305-S828 VMVM25Q400GR305-S828 VMVM25Q250GRD4-S828 VMVM25Q320GRD4-S828 VMVM25Q400GRD4-S828 Stanchion Mount 25° Angle 11⁄2 11⁄2 11⁄2 250 320 400 VMVMJ250GP-S828 VMVMJ250GR305-S828 VMVMJ320GR305-S828 VMVMJ400GR305-S828 VMVMJ250GRD4-S828 VMVMJ320GRD4-S828 VMVMJ400GRD4-S828 Stanchion Mount Straight 11⁄2 11⁄2 11⁄2 250 320 400 VMVMP250GP-S828 VMVMP250GR305-S828 VMVMP320GR305-S828 VMVMP400GR305-S828 VMVMP250GRD4-S828 VMVMP320GRD4-S828 VMVMP400GRD4-S828 Ceiling Mount Thru-Feed Wall Mount Thru-Feed 3⁄4 320 400 320 400 1. Voltage Suffix Multi Tap /MT Standard Voltage Ballasts - 60Hz NEC/UL 120V 480V /120 /480 CEC/CSA (cUL) Tri Tap /TT 120V /120 Optional Voltage Ballasts - 50 or 60Hz EXPORT 2. 756 STIBOINFO((CRH:66008com:3L:756)) CH0 3 L - 2 4 Voltage 220V 60Hz 220V 50Hz 230V 50Hz Suffix /220 /220 50 /230 50 Options - Add the Required Options Suffixes from page 754, In Alpha-numeric Order. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 240V 50Hz /240 50 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0757-2 Name: 3L-757 DATE: JAN 19 2006 Time: 5:48:49 PM Operator: RB COLOR: CMYK ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) 250-400W Metal Halide ɀ VMV High Wattage Series Champ® H.I.D. Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (with Glass Refractor) ɀ Marine (with Globe or Glass Refractor) & Wet Locations ɀ 3, 3R, 4, 4X; IP56 to IP66 3L See Note 1 (to specify voltage) and 2. For guards and other optics, see VMV luminaires - ordering by components section BASIC CATALOG NUMBER Mounting Style Pendant Mount (Rigid or Flexible) Hub Size 3⁄4 1 3⁄4 1 Lamp Watts 250 400 With G303 Globe and P33 Guard VMVM2A250GP VMVM3A250GP N/A N/A With GR305 Glass Refractor VMVM2A250GR305 VMVM3A250GR305 VMVM2A400GR305 VMVM3A400GR305 With GRD4 Reflector/Lens VMVM2A250GRD4 VMVM3A250GRD4 VMVM2A400GRD4 VMVM3A400GRD4 VMVM2C250GP VMVM3C250GP N/A N/A VMVM2C250GR305 VMVM3C250GR305 VMVM2C400GR305 VMVM3C400GR305 VMVM2C250GRD4 VMVM3C250GRD4 VMVM2C400GRD4 VMVM3C400GRD4 VMVM2TW250GP VMVM3TW250GP N/A N/A VMVM2TW250GR305 VMVM3TW250GR305 VMVM2TW400GR305 VMVM3TW400GR305 3⁄4 1 3⁄4 1 250 3⁄4 1 3⁄4 1 250 Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2° Angle 3⁄4 3⁄4 250 400 VMVM25Q250GP N/A VMVM25Q250GR305 VMVM25Q400GR305 VMVM25Q250GRD4 VMVM25Q400GRD4 Stanchion Mount 25° Angle 11⁄2 11⁄2 250 400 VMVMJ250GP N/A VMVMJ250GR305 VMVMJ400GR305 VMVMJ250GRD4 VMVMJ400GRD4 Stanchion Mount Straight 11⁄2 11⁄2 250 400 VMVMP250GP N/A VMVMP250GR305 VMVMP400GR305 Ceiling Mount Thru-Feed Wall Mount Thru-Feed 400 400 1. Voltage Suffix Multi Tap /MT Standard Voltage Ballasts - 60Hz NEC/UL 120V 480V /120 /480 CEC/CSA (cUL) Tri Tap /TT Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts 2. Voltage 208V CWI 240V CWI 600V CWI 220V 60Hz Suffix /208CWI /240CWI /600CWI /220 Options - Add the Required Options Suffixes from page 754, In Alpha-numeric Order. US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:757)) CH0 3 L - 2 4 CAN: 1-800-265-0502 120V /120 EXPORT 220V 50Hz /220 50 Copyright© 2006 Cooper Crouse-Hinds 230V 50Hz /230 50 240V 50Hz /240 50 757 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0758-3 Name: 3L-758 3L DATE: JAN 19 2006 Time: 5:48:50 PM Operator: JB COLOR: CMYK ɀ TCP: 15001 Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) 250-400W Mercury Vapor ɀ VMV High Wattage Series Champ® H.I.D. Luminaires Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence (with Glass Refractor) ɀ Marine (with Globe or Glass Refractor) & Wet Locations ɀ 3, 3R, 4, 4X; IP66 See Note 1 (to specify voltage) and 2. For guards and other optics see VMV - Luminaires - Ordering by Components section. Mounting Style Pendant Mount (Rigid or Flexible) Hub Size 3⁄4 1 3⁄4 1 Lamp Watts 250 BASIC CATALOG NUMBER With GR305 Glass Refractor VMVC2A250GR305 VMVC3A250GR305 VMVC2A400GR305 VMVC3A400GR305 With GRD4 Reflector/Lens2 VMVC2A250GRD4 VMVC3A250GRD4 VMVC2A400GRD4 VMVC3A400GRD4 VMVC2C250GP VMVC3C250GP N/A N/A VMVC2C250GR305 VMVC3C250GR305 VMVC2C400GR305 VMVC3C400GR305 VMVC2C250GRD4 VMVC3C250GRD4 VMVC2C400GRD4 VMVC3C400GRD4 VMVC2TW250GP VMVC3TW250GP N/A N/A VMVC2TW250GR305 VMVC3TW250GR305 VMVC2TW400GR305 VMVC3TW400GR305 VMVC25Q250GP N/A N/A VMVC25Q250GR305 VMVC25Q250GRD4 VMVC25Q400GR305 VMVC25Q400GRD4 VMVCJ250GRD4 VMVCJ400GRD4 With G303 Globe and P33 Guard VMVC2A250GP VMVC3A250GP N/A N/A 400 3⁄4 1 3⁄4 1 250 3⁄4 1 3⁄4 1 250 Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2° Angle 3⁄4 250 400 Stanchion Mount 25° Angle 11⁄2 11⁄2 250 400 VMVCJ250GP N/A VMVCJ250GR305 VMVCJ400GR305 Stanchion Mount Straight 11⁄2 11⁄2 250 400 VMVCP250GP N/A VMVCP250GR305 VMVCP400GR305 Ceiling Mount Thru-Feed Wall Mount Thru-Feed 400 400 3⁄4 1. Voltage Suffix Multi Tap /MT Standard Voltage Ballasts - 60Hz NEC/UL 120V 480V /120 /480 CEC/CSA (cUL) Tri Tap /TT 120V /120 Optional Voltage Ballasts - 50 or 60Hz EXPORT Voltage Suffix 2. 758 STIBOINFO((CRH:66008com:3L:758)) CH0 3 L - 2 3 220V 60Hz /220 220V 50Hz /220 50 230V 50Hz /230 50 Options - Add the required options suffixes from page 754, in Alpha-numeric order. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 240V 50Hz /240 50 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0759-1 Name: 3L-759 100: DATE: JAN 19 2006 Time: 5:48:51 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 VMV High Voltage Luminaires Ordering by Components 3L VMV High Wattage Luminaires are available in components A complete luminaire consists of: I. Champ Cover (mounting module) II. VMV Ballast Housing - Include voltage and required option(s) III. Optical & Guard Components - Globe, Reflector, Refractor, Guard I. Champ Cover (Mounting Module): Type Pendant Ceiling Wall Stanchion - 25 Degree Angle Stanchion - Straight Quad-Mount Conduit 3⁄4 1 3⁄4 1 3⁄4 1 11⁄2 11⁄2 3⁄4 Cat. No. APM2 APM3 CM2 CM3 TWM2 TWM3 JM5 PM5 QM25 II. Ballast Housings. Complete catalog number must have the voltage suffix (MT shown) and any options suffixes. Lamp Type High Pressure Sodium Metal Halide Mercury Vapor Lamp Watts Catalog Number 200 250 400 70 250 400 250 400 VMVS200/MT VMVS250/MT VMVS400/MT LMVM070/MT VMVM250/MT VMVM400/MT VMVC250/MT VMVC400/MT III. Globe, Refractors, Reflectors, Guards Type Globe Globe Guard Reflector-Dome Reflector-Angle Refractor - Type 2 Refractor - Type 5 Refractor Guard High Bay Reflector/Lens Catalog Number G303 P33 RD739 RA739 GR302 GR305 P23 GRD4 US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:759)) CH0 3 L - 3 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 759 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0760-1 Name: 3L-760 3L 100: DATE: JAN 19 2006 Time: 5:48:52 PM Operator: JB 200-400 VMV High Wattage Series COLOR: CMYK TCP: 15001 Family Tree Champ® H.I.D. Luminaires – available with Lightning Service TM delivery. See Section G for complete details. 760 STIBOINFO((CRH:66008com:3L:760)) CH0 3 L - 3 6 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0761-1 Name: 3L-761 DATE: JAN 19 2006 Time: 5:48:53 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Temperature Performance Data 200-400W VMV High Wattage Series 3L Champ® H.I.D. Luminaires Lamp Watts Ambient Temp C Optics Class I (Gas/Vapors) Class II (Dust) and Class III Non Restricted Breathing Restricted Breathing Standard Product Option S826(TB) Division 2 Zone 2 or Division 2 Simultaneous Presence Gas and Dust Present in the Same Area Non Restricted Breathing Restricted Breathing Standard Product Standard Product Option S826 Standard Product Class I, Division 2 and Class II Class I, Zone 2 or Division 2 and Class II Ex nR Supply Wire Temp C Ex nR G303 X – X – – – – GR305 – X – X X X X GRD4 X – – – – – – 325 C 325 C 325 C 350 C 350 C 350 C 350 C T1 325 C 325 C 325 C 350 C 350 C 350 C 350 C T1 T3 T3 T3 T3 T3 T3 T3 T3 T4 T4 – T4 T4 – T4 T4 T3C – – T3C – – T3C – T1/T3C – – T1/T3C – – T1/T3C – T3C – – T3C – – T3C – 75 75 85 75 85 – 85 90 40 55 40 55 350 C 350 C 350 C 350 C 325 C 350 C 325 C 350 C T3 T4 T3 T3 T4 T3 T4 T3 T3B – T3B – 350 C/T3B – 350 C/T3B – T3B – T3B – 85 90 85 90 40 55 40 55 – – – – 325 C – 325 C – T1 – T1 – T4 – T4 – T3B – T3B – 350 C/T3B – 350 C/T3B – T3B – T3B – 85 – 85 – 350 C T1 – – 325 C 350 C 325 C – T3 T3 T1 – T4 T3 T4 – T3B – T3B – 350 C/T3B – 350 C/T3B – T3B – T3B – 85 90 85 – High Pressure Sodium 200 250 400 40 55 65 40 55 65 40 55 Metal Halide 200 (S828) 250 (Includes S828) 320 (S828) 400 (includes S828) Mercury Vapor 250 400 40 55 40 55 US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:761)) CH0 3 L - 3 6 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 761 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0762-1 Name: 3L-762 3L 100: DATE: JAN 19 2006 Time: 5:48:54 PM Operator: JB 200-400W VMV High Wattage Series COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Dimensions and Weights Champ® H.I.D. Luminaires Pendant Mount Ceiling Mount Wall Mount 25° Angle Stanchion Mount QuadMount Straight Stanchion Mount Luminaire with Etched Alzak Reflector/Lens Luminaire with Globe, Guard, Reflectors Net Luminaire Weights (lbs.): Luminaire with: Lamp Globe, Reflector/ Watts Guard Lens 200 291⁄2 30 250 291⁄2 30 400 381⁄2 39 VMVC 250 291⁄2 30 400 33 VMVM 250 321⁄2 33 400 34 Add for mounting modules (lbs): Quad-Mount Pendant 11⁄4 Ceiling 23⁄4 Angle Stanchion Wall 41⁄2 Straight Stanchion Add for reflectors (lbs): 30° Angle Dome 11⁄2 High Bay 13⁄4 Deduct: 11⁄2 lb. for Luminaire without P33 Guard Luminaire Series VMVS 762 STIBOINFO((CRH:66008com:3L:762)) CH0 3 L - 2 5 US: 1-866-764-5454 Glass Refractor 321⁄2 321⁄2 411⁄2 351⁄2 351⁄2 353⁄4 351⁄2 31⁄2 31⁄2 41⁄2 11⁄2 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Luminaire with Glass Refractor, Guard Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0763-2 Name: 3L-763 DATE: JAN 19 2006 Time: 5:49:57 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data 200-400W VMV High Wattage Series 3L Champ® H.I.D. Luminaires Lamp: 250W/E-18 high pressure sodium (HPS) Total bare lamp lumens: 27500 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for high pressure sodium luminaires with 250W/E-18 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages. Consult Cooper Crouse-Hinds for additional photometric data on any Champ series luminaire. Luminaire with Globe and Dome Reflector Temperature Performance Data with Globe & Guard Multipliers (for use with candela curves only) Luminaire Series VMVS Lamp Watts 200 400 Convversion Factors 0.80 1.82 Lamp Ambient Watts Temp °C High Pressure Sodium: 200 40 55 65 250 40 55 65 400 Luminaire spacing ratio: 2.0 Mercury Vapor: 250 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 50 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 % Reflectance Eff. Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 .750 .640 .550 .711 .582 .482 .677 .532 .429 .732 .625 .538 .696 .570 .474 .664 .526 .424 .695 .594 .513 .666 .549 .458 .641 .509 .414 .663 .567 .490 .640 .530 .443 .618 .496 .405 .635 .542 .469 .615 .510 .429 .597 .483 .395 .580 .464 .377 Room Cavity Ratio 6 7 8 .369 .327 .290 .295 .255 .222 .243 .208 .173 .360 .320 .285 .291 .251 .219 .239 .204 .172 .344 .306 .272 .283 .243 .213 .236 .200 .170 .330 .292 .262 .275 .238 .207 .233 .196 .167 .317 .282 .251 .267 .233 .202 .229 .194 .165 .212 .178 .149 80 400 4 5 .476 .402 .346 .465 .397 .343 .443 .384 .336 .423 .372 .330 .405 .360 .323 .305 .416 .341 .285 .405 .335 .282 .388 .326 .279 .371 .316 .273 .355 .307 .268 .251 9 .263 .196 .150 .258 .193 .149 .247 .189 .147 .238 .183 .145 .229 .179 .142 .128 10 .229 .163 .121 .224 .163 .121 .216 .159 .119 .207 .154 .116 .200 .150 .114 .101 US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:763)) CH0 3 L - 2 6 CAN: 1-800-265-0502 Class I Division 2 Globe & Guard Supply Wire °C 325°C 325°C 325°C 350°C 350°C 350°C 75 75 85 75 85 — 40 55 65 T1 T1 — 85 90 — 40 55 65 40 55 65 350°C T1 — — — — 85 85 — 85 — — 350°C 350°C — — — — 75 90 90 75 — — Metal Halide: 250 40 55 65 400 40 55 65 (Data not applicable with QTZ suffix) Temperature Data With GR305 or GR302 Refractor Simultaneous Presence Ambient Class I Class II Class I, Div. 2/ Wattage Temp °C Division 2 Division 1 Class II, Div. 1 High Pressure Sodium 200 40 350°C T3C T1/T3C 55 T1 – – 250 40 350°C T3C T1/T3C 55 T1 – – 400 40 350°C T3C T1/T3C 55 T1 – – 75 75 75 85 85 90 Mercury Vapor 250 40 55 400 40 325°C 350°C 325°C T3B – T3B 350°C/T3B – 350°C/T3B 85 85 85 Metal Halide 250 40 55 400 40 325°C 350°C 325°C T3B – T3B 350°C/T3B – 350°C/T3B 85 90 85 Copyright© 2006 Cooper Crouse-Hinds Supply Wire °C 763 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0764-2 Name: 3L-764 3L 100: DATE: JAN 19 2006 Time: 5:49:58 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data 200-400W VMV High Wattage Series Champ® H.I.D. Luminaires Lamp: 250W/E-28 coated (DX) mercury vapor (MV) Total bare lamp lumens: 13000 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for mercury vapor luminaires, with 250W/E-28 diffuse lamps. Use conversion factors (multipliers) shown below for other diffuse lamp types and wattages. Consult Cooper Crouse-Hinds for additional photometric data on any Champ series luminaire. Luminaire with Etched Alzak® Reflector and Tempered Glass Lens Luminaire with I.E.S. Type V Glass Refractor Multipliers: (for use with candela curves only). Luminaire Series VMVC VMVM Lamp Watts 400 250 400 Multipliers: (for use with candela curves only). Conversion Factor 1.73 1.58 2.77 Luminaire Series VMVC VMVM Conversion Factor 1.73 1.58 2.77 Luminaire spacing ratio: 1.60 Luminaire spacing ratio: 1.30 Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .711 .585 .508 80 30 .659 .524 .430 10 .614 .464 .368 50 .677 .566 .484 70 30 .630 .500 .411 10 .586 .446 .353 50 .611 .509 .435 50 30 .573 .456 .375 10 .538 .409 .326 50 .551 .457 .390 30 30 .521 .414 .341 10 .482 .375 .299 50 .496 .409 .349 10 30 .471 .374 .308 10 .449 .343 .273 0 0 .419 .314 .246 4 .440 .358 .295 .418 .343 .285 .376 .313 .263 .337 .285 .242 .301 .257 .220 .195 5 .384 .304 .244 .365 .291 .234 .330 .266 .217 .296 .242 .200 .265 .219 .182 .159 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .681 .609 .544 80 30 .658 .573 .500 10 .638 .542 .465 50 .667 .598 .536 70 30 .646 .564 .494 10 .627 .537 .461 50 .639 .576 .518 50 30 .622 .548 .482 10 .607 .523 .453 50 .615 .556 .501 30 30 .602 .533 .471 10 .589 .512 .446 50 .594 .537 .486 10 30 .582 .518 .460 10 .571 .501 .438 0 0 .559 .489 .426 4 .483 .433 .394 .476 .429 .391 .459 .419 .387 .445 .410 .382 .432 .401 .377 .364 5 .430 .376 .337 .422 .372 .335 .410 .366 .332 .397 .358 .328 .386 .352 .324 .312 % Reflectance Eff. Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 9 .251 .181 .134 .240 .174 .129 .218 .160 .120 .197 .146 .110 .178 .133 .101 .084 10 .223 .156 .113 .213 .151 .109 .195 .139 .101 .177 .127 .092 .160 .115 .083 .068 % Reflectance Eff. Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 9 .273 .220 .183 .269 .218 .183 .261 .214 .182 .254 .210 .180 .247 .208 .179 .168 10 .234 .182 .148 .230 .182 .148 .225 .178 .147 .218 .175 .145 .213 .173 .144 .133 Room Cavity Ratio 6 7 8 .343 .306 .274 .285 .231 .203 .209 .180 .152 .326 .292 .262 .253 .220 .195 .199 .171 .147 .294 .264 .237 .232 .201 .179 .185 .158 .136 .265 .237 .215 .212 .185 .162 .171 .145 .125 .238 .215 .193 .191 .168 .148 .155 .133 .114 .135 .113 .096 Room Cavity Ratio 6 7 8 .383 .340 .302 .329 .286 .249 .291 .250 .212 .377 .335 .298 .326 .283 .248 .288 .247 .211 .365 .325 .289 .320 .277 .243 .286 .245 .209 .356 .315 .282 .315 .274 .238 .284 .242 .208 .346 .308 .274 .309 .270 .235 .281 .240 .206 .269 .228 .194 Alzak is a registered trademark of Alcoa. 764 STIBOINFO((CRH:66008com:3L:764)) CH0 3 L - 2 7 Lamp Watts 400 250 400 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0765-3 Name: 3L-765 100: DATE: JAN 19 2006 Time: 5:49:59 PM Operator: RB ɀ 50-175W N2MV Series Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Champ® H.I.D. Luminaires Non-Metallic COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups F, G, Cl. III & Simultaneous Presence (100W max) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP56 3L Options: Application: N2MV series Champ luminaires are used: ɀ in areas in which ignitable concentrations of flammable gases or vapors will be present due to abnormal, unusual or accidental conditions. ɀ in installations where moisture, dirt, vibration, corrosion or rough usage are concerns. ɀ wherever the damaging effects of water, wind, snow, sleet, hot sun or any combination of these elements are found. ɀ ideal for marine use; resists the harmful effects of salt water. ɀ withstands the harshest of corrosive environments. ɀ to provide low wattage spot and floodlighting. ɀ for general area lighting. ɀ in areas where the ambient temperature will get as low as 40°C (–40°F). ɀ In manufacturing plants, refineries, chemical, petrochemical and other industrial process facilities, wastewater and sewage treatment facilities, offshore, dockside and harbor installations as well as other heavy industrial applications. Features: ɀ Housing and mounting modules made of polyphenylene sulfide (PPS) for strength and maximum resistance to corrosion. ɀ Pendant mounting module equipped with integral hub set screws for vibration resistance. ɀ Hubs are provided with an integral bushing to help prevent damage to field wiring during installation and ground connection for positive bonding. ɀ Guard, hub inserts, stanchion elbow and hardware made of stainless steel for maximum resistance to corrosion. ɀ Grounding wire for safety. ɀ Stainless steel open bottom guard permits direct access to the globe for easy relamping. ɀ Hinged assembly allows the luminaire to hang free during installation to permit the use of both hands when wiring. ɀ One, external captive screw for ease of installation. ɀ Handle – hinge assembly doubles as a handle for ease of installation, especially when carrying up a ladder. The following special options are available from the factory by adding suffix to luminaire Cat. No.: Suffix to be Description Added to Cat. No. Standard Materials: ɀ Housing, mounting modules, component pallets – polyphenylene sulfide PPS ɀ Guard, hub inserts, stanchion elbow, hardware – stainless steel ɀ Globe – heat tempered ɀ Gaskets – silicone rubber Electrical Ratings: ɀ 120, multi-tap/MT刁 (120, 208, 240 and 277), Dual-Tap/DT (120, 277 volts), Tri-Tap/TT (120, 277, 347 volts) 480 volt, 600 volt, 220/240 volt-50 Hz ɀ 50-150W HPS; 100-175W MV; 70-175W MH Certifications and Compliances: ɀ NEC and CEC: – Class I, Division 2, Groups A, B, C, D – 100W Maximum - Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) – Class 1 Zone 2 ɀ IEC: - Zone 2 Ex nR IIC ɀ UL Standards: - 844, 2279 Hazardous (Classified) Locations - 1598 Luminaires - 1598A Marine Locations ɀ CSA Standards - C22.2 No. 137 ɀ IEC Standards - 60079-15 US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:765)) CH0 3 L - 2 8 ɀ Restricted Breathing Construction. . . . S826 - Class I Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 . . . . . . . . . . S826TB - Furnished with terminal block crimp terminals and dedicated voltage ballasts (no MT, DT, or TT) ɀ Wall Mount Arm. For converting a ceilingmount luminaire to a wall-mount. N2MV-WM1 ɀ Ballast Gard TM starter cut-out switch. Prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 50-150 watt – HPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG ɀ Factory Assembled. For a factory assembled luminaire with lamp installed . . FA ɀ Instant Restrike. Enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage. It has no effect on the warm-up period of cold lamps. Available for use with 50-150W LX HPS only. . . . . . . . . . . . . . . . . . . IR ɀ Quartz Auxiliary Lighting. Comes to full brightness immediately and remains lit until the HID lamp attains 60–70% of full illumination. For non-hazardous locations only. (Note: QTZ lamp not included; use 100W single ended lamp – Q100DC, Q100CL/ DC, or 100Q/CL/DC) Consult factory for top-hat limitations . . . . . . . . . . . . . . . . . . . . QTZ ɀ Fused. To protect ballast and capacitor against abnormal line conditions . . . . . . S658 (Not for use in Canada) ɀ Furnished with Lamps. . . . . . . . . . . . . . . S714 ɀ Teflon® Coated Globe. For additional protection against breakage. For use with 50–100W HPS, 70–175W MH and 100–175W MV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S808 Accessories: ɀ See pages 775 and 776 for complete listing. CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 765 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0766-4 Name: 3L-766 3L DATE: JAN 19 2006 Time: 5:50:00 PM Operator: RB COLOR: CMYK ɀ 50-150W High Pressure Sodium Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ N2MV Series Champ® H.I.D. Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups F, G, Cl. III & Simultaneous Presence (100W max) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP56 See notes 1 (to specify voltage) 2 and 3. For guards and other optics see N2MV Luminaires - Ordering by Components Section. BASIC CATALOG NUMBER Mounting Style Pendant Mount Ceiling Mount Thru-Feed Stanchion Mount 25° Angle Hub Size 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 11⁄2 11⁄2 11⁄2 11⁄2 Lamp Watts 50 70 100 150 50 70 100 150 50 70 100 150 With G303 Globe and P33 Guard N2MVS2A050GP N2MVS3A050GP N2MVS2A070GP N2MVS3A070GP N2MVS2A100GP N2MVS3A100GP N2MVS2A150GP N2MVS3A150GP N2MVS2C050GP N2MVS3C050GP N2MVS2C070GP N2MVS3C070GP N2MVS2C100GP N2MVS3C100GP N2MVS2C150GP N2MVS3C150GP N2MVSJ050GP N2MVSJ070GP N2MVSJ100GP N2MVSJ150GP With GR305 Glass Refractor N2MVS2A050GR305 N2MVS3A050GR305 N2MVS2A070GR305 N2MVS3A070GR305 N2MVS2A100GR305 N2MVS3A100GR305 N2MVS2A150GR305 N2MVS3A150GR305 N2MVS2C050GR305 N2MVS3C050GR305 N2MVS2C070GR305 N2MVS3C070GR305 N2MVS2C100GR305 N2MVS3C100GR305 N2MVS2C150GR305 N2MVS3C150GR305 N2MVSJ050GR305 N2MVSJ070GR305 N2MVSJ100GR305 N2MVSJ150GR305 Standard Voltage Ballasts - 60Hz 1. Voltage Suffix Multi Tap /MT NEC/UL Dual Tap /DT 120V /120 480V /480 Tri Tap /TT CEC/CSA (cUL) Dual Tap 120V /DT /120 Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 480V CWI /480CWI 600V CWI /600CWI EXPORT 220V 60Hz /220 220V 50Hz /220 50 2. 150W HPS Luminaires, 55V Lamps is standard, for 100V lamps - Add suffix ‘‘CE’’. 50W HPS luminaire is dual-tap only. 3. Options - Add the required options suffixes from page 765, In Alpha-numeric order. 766 STIBOINFO((CRH:66008com:3L:766)) CH0 3 L - 2 9 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 230V 50Hz /230 50 240V 50Hz /240 50 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0767-8 Name: 3L-767 DATE: JAN 19 2006 150-175W Pulse Start Metal Halide N2MV Series Champ® H.I.D. Luminaires Time: 5:50:01 PM Operator: RB ɀ COLOR: CMYK Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups F, G, Cl. III & Simultaneous Presence (100W max) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP56 3L See notes 1 (to specify voltage) and 2. For guards and other optics see N2MV Luminaires - Ordering by Components Section. BASIC CATALOG NUMBER Mounting Style Pendant Mount Ceiling Mount Thru-Feed Stanchion Mount 25° Angle Hub Size 3⁄4 1 3⁄4 1 Lamp Watts 150 175 3⁄4 150 1 3⁄4 1 175 11⁄2 11⁄2 150 175 With G303 Globe and P33 Guard N2MVM2A150GP-S828 N2MVM3A150GP-S828 N2MVM2A175GP-S828 N2MVM3A175GP-S828 With GR305-S828 Glass Refractor N2MVM2A150GR305-S828 N2MVM3A150GR305-S828 N2MVM2A175GR305-S828 N2MVM3A175GR305-S828 N2MVM2C150GP-S828 N2MVM3C150GP-S828 N2MVM2C175GP-S828 N2MVM3C175GP-S828 N2MVM2C150GR305-S828 N2MVM3C150GR305-S828 N2MVM2C175GR305-S828 N2MVM3C175GR305-S828 N2MVMJ150GP-S828 N2MVMJ175GP-S828 N2MVMJ150GR305-S828 N2MVMJ175GR305-S828 1. Voltage Suffix 2. Multi Tap /MT STIBOINFO((CRH:66008com:3L:767)) CEC/CSA (cUL) Tri Tap /TT Optional Voltage Ballasts - 50 or 60Hz EXPORT Voltage 220V 60Hz 220V 50Hz 230V 50Hz Suffix /220 /220 50 /230 50 Options - Add the required options suffixes from page 765, In Alpha-numeric order US: 1-866-764-5454 CH0 3 L - 3 0 Standard Voltage Ballasts - 60Hz NEC/UL 120V 480V /120 /480 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 120V /120 240V 50Hz /240 50 767 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0768-3 Name: 3L-768 3L DATE: JAN 19 2006 Time: 5:50:02 PM Operator: RB COLOR: CMYK TCP: 15001 ɀ Cl. II Groups F, G, Cl. III & Simultaneous Presence (100W max) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP56 ɀ 70-175W Metal Halide Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ N2MV Series Champ® H.I.D. Luminaires Typedriver Name: TS name csm no.: 100 See notes 1 (to specify voltage), 2 and 3. For guards and other optics see N2MV Luminaires - Ordering by Components Section. BASIC CATALOG NUMBER Mounting Style Pendant Mount Ceiling Mount Thru-Feed Stanchion Mount 25° Angle Hub Size 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 Lamp Watts 70 100 175 70 1 3⁄4 1 3⁄4 1 100 175 11⁄2 11⁄2 11⁄2 070 100 175 With G303 Globe and P33 Guard Cat. No. N2MVM2A070GP N2MVM3A070GP N2MVM2A100GP N2MVM3A100GP N2MVM2A175GP N2MVM3A175GP With GR305 Glass Refractor Cat. No. N2MVM2A070GR305 N2MVM3A070GR305 N2MVM2A100GR305 N2MVM3A100GR305 N2MVM2A175GR305 N2MVM3A175GR305 N2MVM2C070GP N2MVM3C070GP N2MVM2C100GP N2MVM3C100GP N2MVM2C175GP N2MVM3C175GP N2MVM2C070GR305 N2MVM3C070GR305 N2MVM2C100GR305 N2MVM3C100GR305 N2MVM2C175GR305 N2MVM3C175GR305 N2MVMJ070GP N2MVMJ100GP N2MVMJ175GP N2MVMJ070GR305 N2MVMJ100GR305 N2MVMJ175GR305 100-175W Mercury Vapor N2MV Series Champ® H.I.D. Luminaires ɀ Cl. II Groups F, G, Cl. III & Simultaneous Presence (100W max) ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP56 ɀ Cl. I, Div 2, Groups A, B, C, D ɀ Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) BASIC CATALOG NUMBER Mounting Style Pendant Mount Ceiling Mount Thru-Feed Stanchion Mount 25° Angle Hub Size 3⁄4 1 3⁄4 1 Lamp Watts 100 175 3⁄4 100 1 3⁄4 1 175 11⁄2 11⁄2 100 175 With G303 Globe and P33 Guard N2MVC2A100GP N2MVC3A100GP N2MVC2A175GP N2MVC3A175GP With GR305 Glass Refractor N2MVC2A100GR305 N2MVC3A100GR305 N2MVC2A175GR305 N2MVC3A175GR305 N2MVC2C100GP N2MVC3C100GP N2MVC2C175GP N2MVC3C175GP N2MVC2C100GR305 N2MVC3C100GR305 N2MVC2C175GR305 N2MVC3C175GR305 N2MVCJ100GP N2MVCJ175GP N2MVCJ100GR305 N2MVCJ175GR305 1. Voltage Suffix Multi Tap /MT Standard Voltage Ballasts - 60Hz NEC/UL 120V 480V /120 /480 CEC/CSA (cUL) Tri Tap /TT Optional Voltage Ballasts - 50 or 60Hz CEC/CSA (cUL) - CWI Isolated Ballasts 2. 3. 768 STIBOINFO((CRH:66008com:3L:768)) CH0 3 L - 3 0 Voltage 208V CWI 240V CWI 600V CWI Suffix /208CWI /240CWI /600CWI 70W Ballast not available in 480V. Options - Add the required options suffixes from page 765, in Alpha-numeric order. US: 1-866-764-5454 CAN: 1-800-265-0502 120V /120 EXPORT 220V 60Hz /220 220V 50Hz /220 50 Copyright© 2006 Cooper Crouse-Hinds 230V 50Hz /230 50 240V 50Hz /240 50 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0769-3 Name: 3L-769 100: DATE: JAN 19 2006 Time: 5:50:03 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 N2MV Luminaires Ordering by Components 3L N2MV luminaires are available in components A complete luminaire consists of: I. N2MV Cover (mounting module) II. N2MV Ballast Housing - Include voltage and required option(s) III. Globe, Refractor, Guard, Reflector I. N2MV Cover (Mounting Module): Type Pendant Conduit 3⁄4 Ceiling Wall (Use wall bracket accessory with Ceiling Cover) Stanchion - 25 Degree Angle 1 3⁄4 1 3⁄4 1 11⁄2 Cat. No. N2APM2 N2APM3 N2CM2 N2CM3 N2MV - WM1 and N2CM2 N2MV - WM1 and N2CM3 N2JM5 II. Ballast Housings. Complete catalog number must have the voltage suffix (MT shown) and any options suffixes. Lamp Type High Pressure Sodium Metal Halide Mercury Vapor Lamp Watts 50 70 100 150 70 100 175 100 175 Catalog Number N2MVS050/MT N2MVS070/MT N2MVS100/MT N2MVS150/MT LX N2MVM070/MT N2MVM100/MT N2MVM175/MT N2MVC100/MT N2MVC175/MT III. Globe, Refractors, Guards and Reflectors Type Globe Globe Teflon Coated Globe Guard Reflector-Dome Reflector-Angle Refractor - Type 2 Refractor - Type 5 Refractor Guard Large Plastic Refractor Type 2 Large Plastic Refractor Type 3 Large Plastic Refractor Type 5 Catalog Number G303 G303-S808 P33 RD739 RA739 GR302 GR305 P23 PGR302 PGR303 PGR305 US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:769)) CH0 3 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 769 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0770-1 Name: 3L-770 3L 100: DATE: JAN 19 2006 Time: 5:50:04 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Family Tree 50-175W N2MV Series Non-Metallic Champ® H.I.D Luminaires N2MV Champ Series Luminaire A complete luminaire consists of a cover mount, a ballast housing and a globe, with or without guard, refractor or reflector. * These plastic refractors are for non-hazardous areas only (50–100W max.) 770 STIBOINFO((CRH:66008com:3L:770)) CH0 3 L - 3 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0771-1 Name: 3L-771 DATE: JAN 19 2006 Time: 5:50:05 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Temperature Performance Data 50-175W N2MV Series 3L ® Champ H.I.D Luminaires Lamp Watts Ambient Temp C Optics Class I (Gas/Vapors) Class II (Dust) and Class III Non Restricted Breathing Restricted Breathing Standard Product Option S826(TB) Division 2 Zone 2 or Division 2 G303 X X GR305 X X T3A T3A – T3A T3A – T2D T2C – T2C – – Simultaneous Presence Gas and Dust Present in the Same Area Supply Wire Temp C Non Restricted Breathing Restricted Breathing Standard Product Option S826 Class I, Division 2 and Class II Class I, Zone 2 or Division 2 and Class II X X X X X X T5 T5 – T5 T5 – T5 T4 – T4 – – T4A – – T4A – – T4A – – – – – T2C/T4A – – T2C/T4A – – T2C/T4A – – – – – T4A – – T4A – – T4A – – – – – 75 85 – 75 85 – 85 100 – 85 – – T3C T3B – T2B T2B – T2 – – T2 – – T5 T5 – T4 T4 – T3 – – T3 – – T4 – – T4 – – – – – – – – T2B/T4 – – T2B/T4 – – – – – – – – T4 – – T4 – – – – – – – – 75 85 – 85 – – – – – – – – T2B T2B – T2 – – T4 T4 – T3 – – T4 – – – – – T2B/T4 – – – – – T4 – – – – – 75 85 – 85 – – US: 1-866-764-5454 CAN: 1-800-265-0502 Ex nR Ex nR Standard Product High Pressure Sodium 50 70 100 150 40 55 65 40 55 65 40 55 65 40 55 65 Metal Halide 70 100 150 (S828) 175 (Includes S828) 40 55 65 40 55 65 40 55 65 40 55 65 Mercury Vapor 100 175 STIBOINFO((CRH:66008com:3L:771)) CH0 3 L - 3 0 40 55 65 40 55 65 Copyright© 2006 Cooper Crouse-Hinds 771 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0772-1 Name: 3L-772 3L DATE: JAN 19 2006 Time: 5:50:05 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Dimensions and Weights 50-175W N2MV Series Champ® H.I.D. Luminaires Non-Metallic N2MV Dimensions Ceiling Mount Ceiling Mount – Top View 25° Angle Stanchion Mount Pendant Mount Net Luminaire Weights (lbs.) Wall Arm Mount 772 STIBOINFO((CRH:66008com:3L:772)) CH0 3 L - 3 2 US: 1-866-764-5454 CAN: 1-800-265-0502 Luminaire with Luminaire with Globe, Guard Luminaire Lamp Globe, Guard Lamp Series Watts (lbs.) Watts (lbs.) N2MVS 50 23 70 231⁄16 100 241⁄16 150 261⁄8 N2MVC 100 211⁄16 175 221⁄4 250 24 N2MVM 70 21 100 211⁄16 175 221⁄4 250 24 Add for mounting modules (lbs.): Pendant 11⁄4 Flexible Pendant 11⁄2 Ceiling 23⁄4 Wall 41⁄2 Quad Mount 31⁄2 Angle Stanchion 31⁄2 Straight Stanchion 41⁄2 Add for reflectors (lbs.): Dome 11⁄4 30° Angle 13⁄4 Deduct: 1 lb. for luminaire without P33 Guard. Add: 51⁄2 lbs. for luminaire with GR305 refractor. Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0773-2 Name: 3L-773 100: DATE: JAN 19 2006 Time: 5:50:07 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data 50-175W N2MV Series 3L Champ® H.I.D. Luminaires Non-Metallic Lamp: 150W/E-23-1/2 clear high pressure sodium (HPS) Total bare lamp lumens: 16000 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for high pressure sodium luminaires with 150W/E-231⁄2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages. Consult Cooper Crouse-Hinds for additional photometric data on any Champ series luminiares. Luminaire with Globe and Dome Reflector Multipliers: (for use with candela curves only). Isofootcandle Chart: Luminaire with Globe and Dome Reflector ConLuminaire Lamp version Series Watts Factor N2MVS 50 0.25 70 0.40 100 0.59 Luminaire spacing ratio: 1.90 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .759 .643 .551 80 30 .719 .582 .480 10 .683 .530 .424 50 .740 .627 .538 70 30 .703 .570 .471 10 .669 .523 .418 50 .703 .595 .512 50 30 .672 .548 .455 10 .645 .506 .408 50 .669 .567 .488 30 30 .646 .528 .439 10 .622 .492 .399 50 .640 .541 .466 10 30 .619 .508 .424 10 .600 .479 .389 0 0 .582 .459 .370 4 .476 .400 .342 .465 .394 .338 .442 .381 .332 .422 .368 .325 .403 .356 .318 .299 5 .418 .340 .283 .406 .334 .280 .388 .324 .276 .370 .314 .270 .354 .305 .265 .247 % Reflectance Eff. Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 9 .267 .198 .151 .262 .195 .151 .250 .190 .148 .240 .184 .146 .231 .180 .143 .128 10 .231 .164 .121 .226 .164 .121 .218 .159 .119 .209 .154 .116 .201 .150 .114 .100 Room Cavity Ratio 6 7 8 .371 .330 .294 .296 .257 .224 .243 .208 .174 .362 .323 .288 .291 .252 .221 .238 .204 .173 .345 .309 .275 .283 .244 .215 .235 .201 .170 .331 .294 .265 .275 .239 .208 .231 .196 .168 .317 .284 .253 .266 .233 .203 .227 .193 .165 .210 .177 .149 US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:773)) CH0 3 L - 3 3 CAN: 1-800-265-0502 Isofootcandle Chart: Luminaire with Globe and 30° Angle Reflector Isofootcandle charts show illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights. Height (Ft.) Factor Height (Ft.) Factor 8 1.56 16 .391 12 .694 20 .250 14 .510 Copyright© 2006 Cooper Crouse-Hinds 773 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0774-2 Name: 3L-774 3L 100: DATE: JAN 19 2006 Time: 5:50:08 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data 50-175W N2MV Series Champ® H.I.D. Luminaires Non-Metallic Lamp: 175W/E-28 coated mercury vapor (MV) Total bare lamp lumens: 8600 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for mercury vapor luminaires with 175W/E-28 diffuse lamps. Use conversion factors (multipliers) shown below for other diffuse lamp types and wattages. Consult Cooper CrouseHinds for additional photometric data on any Champ series luminaire. Luminaire with Globe and Dome Reflector Multipliers: (for use with candela curves only). Isofootcandle Chart: Luminaire with Globe and Dome Reflector ConLuminaire Lamp version Series Watts Factor N2MVC 100 0.49 250 1.41 N2MVM 175 250 1.63 2.38 Luminaire spacing ratio: 1.7 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .723 .619 .536 80 30 .684 .561 .470 10 .649 .512 .417 50 .705 .604 .524 70 30 .668 .549 .461 10 .635 .505 .412 50 .668 .572 .498 50 30 .638 .528 .445 10 .611 .488 .401 50 .635 .545 .474 30 30 .611 .508 .429 10 .588 .474 .391 50 .606 .519 .453 10 30 .585 .488 .414 10 .566 .460 .381 0 0 .549 .442 .363 4 .467 .396 .342 .456 .390 .338 .434 .377 .331 .414 .365 .324 .395 .352 .317 .299 5 .412 .340 .286 .401 .334 .283 .384 .324 .279 .366 .314 .273 .350 .305 .268 .251 % Reflectance Eff. Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 9 .269 .204 .160 .263 .201 .159 .252 .196 .157 .243 .190 .154 .233 .186 .151 .138 10 .234 .172 .131 .229 .171 .131 .221 .166 .128 .212 .162 .126 .205 .157 .123 .110 774 STIBOINFO((CRH:66008com:3L:774)) CH0 3 L - 3 4 Room Cavity Ratio 6 7 8 .368 .329 .294 .298 .261 .229 .248 .215 .182 .359 .322 .289 .293 .256 .226 .244 .211 .181 .343 .308 .276 .284 .248 .220 .240 .207 .178 .329 .294 .266 .276 .243 .213 .236 .203 .176 .315 .284 .255 .268 .236 .208 .231 .200 .173 .216 .184 .158 US: 1-866-764-5454 CAN: 1-800-265-0502 Isofootcandle Chart: Luminaire with Globe and 30° Angle Reflector Isofootcandle charts show illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights. Height (Ft.) Factor Height (Ft.) Factor 8 1.56 16 .391 12 .694 20 .250 14 .510 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0775-2 Name: 3L-775 DATE: JAN 19 2006 Time: 5:50:08 PM Operator: JB Champ® H.I.D. Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Accessories 3L VMV, LMV, DMV, VMV High Wattage & N2MV Series Globes Reflectors G54 Dome – Krydon® material 30° Angle – Krydon material G24 G303 Lamp Watts 35-150 50-175 50-250 200-400 250 50-175 Luminaire Series LMVS, LMVM VMVC, VMVM, VMVS DMVC, DMVM, DMVS VMVS VMVC, VMVM N2MVC, N2MVM, N2MVS Lamp Watts 35-150 Type Heat/impact resistant Heat/impact resistant Heat/impact resistant Heat/impact resistant Heat/impact resistant Cat. # G54 G24 G303 G303 G303 50-175 50-250 Heat/impact resistant G303 50-175 200-400 250 Luminaire Series LMVS, LMVM Dome Cat. # RD636 (RD66) VMVC, VMVM, VMVS RD70 DMVC, DMVM, DMVS RD739 (RD79) VMVS RD739 (RD79) VMVC, VMVM RD739 (RD79) N2MV, N2MVF(B) RD739 Angle Cat. # RA636 (RA66) RA70 RA739 (RA79) RA739 (RA79) RA739 (RA79) RA740 Guards P50 – use with G54 globe Reflector/Lens – Etched Alzak aluminum reflector/tempered glass lens P21 – use with G24 globe P33 – use with G303 globe Lamp Watts 200-400 70-250 Luminaire Series VMVC, VMVM, VMVS DMVS, DMVC, DMVM Type Reflector/Lens Cat. # GRD4 Reflector/Lens GRD4 Globes – Teflon Coated Teflon coated for increased shatter protection Lamp Watts 50-175 50-175 P23 – use with refractors Lamp Watts 35-150 50-175 50-250 200-400 250 Refractors 50-175 Luminaire Series LMVS, LMVM VMVC, VMVM, VMVS DMVC, DMVM, DMVS VMVS VMVC, VMVM All N2MVC, N2MVM, N2MVS Type Copper-free aluminum Copper-free aluminum Stainless steel Stainless steel Stainless steel Stainless steel Cat. # P50 P21 P33 P33 P33 P23 Stainless steel P33 Luminaire Series VMVC, VMVM, VMVS DMVC, DMVM, DMVS Cat. # G24-S808 G303-S808 Alzak is a registered trademark of Alcoa. Teflon is a registered trademark of E.I. DuPont Co. – available with Lightning Service TM delivery. See Section G. for complete details. US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:775)) CH0 3 L - 3 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 775 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0776-1 Name: 3L-776 DATE: JAN 19 2006 Time: 5:50:11 PM Operator: JB Champ® H.I.D. Luminaires 3L COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Accessories VMV, DMV & VMV High Wattage and N2MV Series Safety Lighting Options Refractors Quartz Auxiliary Lamp R2, R5, PR2, PR3, PR5 Lamp Watts 50-175 200-400 50-250 50-175 GR302, GR305 Luminaire Series VMVC, ⎫ VMVM, ⎬ VMVS ⎭ I.E.S. Type II III V Glass Cat. # R2 VMVC, ⎫ VMVM, ⎬ VMVS ⎭ II V GR302 GR305 II III V GR302 DMVC, DMVS, DMVM N2MV ⎫ ⎬ ⎭ R5 GR305 Plastic (100W max. non hazardous) Cat. # PR2 PR3 PR5 Instant Restrike PGR302 PGR303 PGR305 Type II Factory installed instant restrike device will restart a hot high pressure sodium lamp (50-150W LX) after a momentary power interruption, without the typical delay for cooling. Instant restrike for use in 50-150W ‘‘LX’’ HPS luminaires. Add suffix IR to Cat. No. Ballast-gard TM Ballast-gard starter cut-out switch prevents starter pulsing after a time delay of approximately two minutes if the lamp fails to start. For use in 50-400 watt HPS luminaires only. Add suffix BG to Cat. No. I.E.S. Distribution Curves Type I The quartz auxiliary lamp comes to full brightness instantly and remains lit until the H.I.D. lamp attains 60-70% of full illumination. Quartz auxiliary lamps can be used with all DMV, VMV and VMV high wattage series Champ® luminaires. Use for non-hazardous applications ONLY. (NOTE: VMV luminaires (50-175W) ordered with this option must use large glass refractor optics, not compact refractors). Quartz auxiliary lamp (100W single ended lamp – Q100CL/DC, Q100DC or 100Q/CL/DC NOT furnished) Add suffix QTZ to Cat. No. Type III Type V Compact Refractors G241, G245 With optional P241 wire guard. Luminaire IES Glass Series Type Cat. # VMVC, ⎫ I G241 VMVM, ⎬ V G245 VMVS ⎭ Optional stainless steel wire guard P241 Lamp Watts 50-175 776 STIBOINFO((CRH:66008com:3L:776)) CH0 3 L - 3 6 US: 1-866-764-5454 CAN: 1-800-265-0502 – available with Lightning Service TMdelivery. See Section G for complete details Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0777-1 Name: 3L-777 100: DATE: JAN 19 2006 Time: 5:50:13 PM Operator: JB ɀ V2PC Photocell ɀ COLOR: CMYK TCP: 15001 Cl. I, Div. 2, Groups A,B,C,D Maintains Cl. I, Div 2 Suitability of Cooper Crouse-Hinds Champ® Series Luminaires Typedriver Name: TS name csm no.: 100 3L The only UL recognized photocell for Class I, Division 2 areas eliminates the need for an explosionproof box. When mounting in EIH enclosures for Class I, Division 1 applications (EV21H Series) seals are not required for Groups C & D. Cooper Crouse-Hinds V2PC factory-sealed, field installed photocell offers reliable, duskto-dawn lighting control in Class I, Division 2 locations. The V2PC is ideal for walkways, security lighting, and any other outdoor lighting application that utilizes Champ® H.I.D. lighting luminaires. Applications: The V2PC is designed: ɀ to provide control for automatic dusk-todawn lighting. ɀ for use with LMV, DMV, VMV, VMV High Wattage, N2MV and FMV Series Champ® lighting luminaires. ɀ for use on 35-400 watt H.I.D., incandescent, or fluorescent lighting luminaires. ɀ to save energy by operating luminaires only when necessary. ɀ for safety by turning on outdoor luminaires in critical passageways at night. ɀ for walkways, parking areas, outdoor process areas, security lighting, or any outdoor lighting application in Class I, Division 2 locations and corrosive environments. ɀ for remote mounting in FS boxes (D2S Series). ɀ for mounting in EIH enclosures for Class I, Division 1 applications (EV2IH Series). Features: ɀ Field-installable. ɀ Solid-state design for performance and dependability. ɀ Factory sealed components. Explosionproof enclosure not required for Class I, Division 2 locations. ɀ Luminaires turn on at 3 footcandles, off at 8 footcandles insuring that the luminaires are operating only when needed. ɀ Built-in 10 second time delay to eliminate nuisance tripping. ɀ Eight-year operating life. ɀ Furnished with 6⍯ stranded 600 volt color coded wire leads. ɀ Constructed from corrosion-resistant thermoplastic polyester. ɀ Available on a DS cover for use with any FS/FD box (D2S Series). ɀ Available in an EIH enclosure for use in Class I, Division 1, Groups B†, C, and D locations (EV2IH Series). No seals required. Certifications and Compliances: V2PC and D2S ɀ NEC/CEC: Class I, Division 2, Groups A, B, C, D ɀ UL Standard: 844 – Hazardous (Classified) Locations ɀ CSA: C22.2 No. 55 EV2IH ɀ NEC/CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1, Groups E, F, G Class II, Division 2, Groups F, G Class III ɀ NEMA: 3, 4, 7BCD, 9EFG ɀ UL Standard: 844 – Hazardous (Classified) Locations ɀ CSA: C22.2 No. 30, 55 Options: To order luminaire with photocell factory installed: 1. Specify luminaire dedicated supply voltage (not MT, DT, or TT) 2. Add photocell Cat. No. to fixture Cat. No. as follows: V2PC20 V2PC22 V2PC27 Example: VMVSJ070GP/120-V2PC20 is a 120V 60Hz luminaire with a factory installed photocell. Electrical Rating Ranges: ɀ 120, 208, 220, 240, 277 VAC ɀ 50/60 Hz ɀ 35-400 watt H.I.D., incandescent, or fluorescent ɀ V2PC20 – 3.3A max. current rating ɀ V2PC22 – 1.8A max. current rating ɀ V2PC27 – 1.4A max. current rating † For Group B applications, seal within 11⁄2⍯ of enclosure in accordance with Section 501-5 of the National Electric Code®. US: 1-866-764-5454 STIBOINFO((CRH:66008com:3L:777)) CH0 3 L - 3 7 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 777 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0778-2 Name: 3L-778 3L DATE: JAN 19 2006 Time: 5:50:14 PM Operator: RB ɀ V2PC Photocell ɀ Dimensions Ordering Information COLOR: CMYK TCP: 15001 Cl. I, Div. 2, Groups A,B,C,D Maintains Cl.I, Div. 2 Suitability of Cooper Crouse-Hinds Champ® Series Luminaires Dimensions: V2PC D2S EV2IH Cat. # EV2IH a 5.00 b 4.25 c 2.60 d 4.54 e 5.25 Ordering Information Photocell for field installation* Catalog # V2PC20 V2PC22 V2PC27 Voltage Range 120V, 50/60 Hz 208-240V, 50/60 Hz 277V, 50/60 Hz * Must be factory installed in Canada — see page 777. Photocell in DS cover for use with FS/FD box Catalog # Voltage Range D2S20 120V, 50/60 Hz D2S22 208-240V, 50/60 Hz D2S27 277V, 50/60 Hz Photocell in EIH enclosure for use in Class I, Division 1, Groups B, C, and D; Class II, Division 1, Groups E, F, and G; and Class III locations Catalog # Voltage Range EV2IH20 120V, 50/60 Hz EV2IH22 208-240V, 50/60 Hz EV2IH27 277V, 50/60 Hz 778 STIBOINFO((CRH:66008com:3L:778)) CH0 3 L - 3 8 US: 1-866-764-5454 CAN: 1-800-265-0502 Typedriver Name: TS name csm no.: 100 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0779-2 Name: 4L-779 100: DATE: JAN 19 2006 Time: 5:50:16 PM Operator: RB COLOR: CMYK TCP: 15001 High Intensity Discharge (H.I.D.) Luminaires Hazardous Typedriver Name: TS name csm no.: 100 4L Description Page No. Application/Selection 780 Class I Hazardous Area Lighting Integrally Ballasted Luminaires EVLP Lo-ProTM Hazard ȿ Gard® Series EVM Hazard ȿ Gard® Series HPS, Pulse Start MH, MH, MV 781-791 792-800 Class II Hazardous Area Lighting Integrally Ballasted Luminaires EVLP Lo-ProTM Hazard ȿ Gard® Series EVM Hazard ȿ Gard® Series HPS, Pulse Start MH, MH, MV US: 1-866-764-5454 STIBOINFO((CRH:66008com:4L:779)) CH0 0 0 0 5 L CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 781-791 792-800 779 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0780-2 Name: 4L-780 4L DATE: JAN 19 2006 Time: 5:50:16 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 High Intensity Discharge (H.I.D.) Luminaires Hazardous Application and Selection Quick Selector Chart Application: Luminaires contained in this section are for use: ɀ in indoor or outdoor hazardous locations ɀ as general area or spot lighting applications ɀ where longer lamp life provides desirable maintenance cost savings and return on investment through use of fewer luminaires, circuits and ancillary apparatus ɀ where relamping and maintenance difficulties require longer lamp life Table 500-3(d) Identification Numbers. Maximum Temperature Deg. C Deg. F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185 Considerations for Selection: Environmental: ɀ Make sure luminaire meets NEC/CEC requirements for area in which it will be used Lighting levels required: ɀ Can luminaire accept lamp of sufficient size to yield desired light level (see Lighting Selector Guide to determine the number and location of luminaires required) NOTE: For details on luminaire selection and methods for determining number and location luminaires, see Lighting Selector Guide, pages 665 to 689. Identification Number T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Quick Selector Chart Series Electrical Characteristics Watts Cl. I, Groups B, C, D Volts Ballast 50, 70, 100, 150, 175, 200, 250, 320, 400 (Mogul base) 120, 208, 240, 277, 347, 480, 600, MT High power factor, constant wattage, reactor or autotransformer Cl. II, Groups E, F, G 50, 70, 100, 150, 175 (Mogul base) 120, 208, 240, 277, 347, 480, 600, MT integral Champ® Series (see Section 3L) Cl. II, Groups E, F, G 70, 100, 150, 175 (Mogul base) 120, 208, 240, 277, 347, 480, 600, MT High power factor, constant wattage integral EVLP Hazard ȿ Gard TM Cl. I, Groups B, C, D 70, 100, 150, 175 (Medium base) 70, 100, 150, 175, 200, 250 (Mogul base) 120, 208, 240, 277, 347, 480, MT, TT High power factor, constant wattage, reactor or autotransformer, integral. Cl. II, Groups E, F, G Cl. III 70, 100 (Medium base) 70, 100, 150, 175 (Mogul base) 120, 208, 240, 277, 347, 480, MT, TT EVM Hazard ȿ Gard TM 780 STIBOINFO((CRH:66008com:4L:780)) CH0 0 5 L - 0 NEC Compliance US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0781-4 Name: 4L-781 100: DATE: JAN 19 2006 Time: 5:50:17 PM Operator: JB EVLP Low Profile Hazard ȿ Gard® (H.I.D.) Luminaires Medium and Mogul Base COLOR: CMYK ɀ TCP: 15001 Cl. I, Div. 1, Groups B (GB suffix), C, D Cl. I, Zone 1 Groups IIB + H2 (with suffix – GB), IIB, IIA ɀ Cl. II, Div. 1 Groups E, F, G; Class III, Simultaneous Presence (175W max) ɀ Typedriver Name: TS name csm no.: 100 ɀ Marine & Wet Locations ɀ 3,3R, 4,4X; IP66 4L Application: Cooper Crouse-Hinds Low Profile Hazard ȿ Gard® luminaires are used in: ɀ areas where flammable or explosive vapors or gases are present ɀ hazardous areas, both indoors and outdoors, where long life and low maintenance costs are desired ɀ petroleum refineries, chemical, petrochemical and pharmaceutical plants, oil terminals, gas plants and other heavy process industry facilities ɀ waste treatment facilities ɀ drilling platforms and other coastal and offshore hazardous areas Features - Benefits: ɀ Small compact size is perfect where low mounting restrictions are a concern. ɀ Two start Acme threaded construction allows for easier assembly, installation and maintenance. ɀ Light weight copper-free aluminum housing with powdered epoxy finish for superior corrosion resistance. ɀ All exterior hardware is corrosion-resistant stainless steel. ɀ Four mounting arrangements; pendant, ceiling, wall bracket and stanchion suit any lighting layout. ɀ Wide range of light sources and wattages to meet specific lighting needs. ɀ Marine and Nema 4X construction suitable for outdoor, hose down, marine and corrosive environments. ɀ Integral ballast for lowest installed cost. ɀ High power factor (90%+) ballasts allows more fixtures per circuit. ɀ Uses same mounting modules as the standard Hazard ȿ Gard® for easy retrofitting when the Lo-Pro TM is the preffered choice. ɀ Internally fluted glass globe reduce glare and distributes light evenly – ideal for adverse enviroments typical of industrial facilities. ɀ Krydon® construction dome and angle reflectors – won’t rust, corrode, dent, chip or peel ɀ Now available in components – luminaire body, mounting module, guard, reflectors – allowing for easy stocking for Quick Ship requirements. Standard Materials: ɀ Mounting modules, cover, ballast housing, globe holder – copper free aluminum ɀ Globe – heat and impact resistant glass ɀ Exterior hardware – stainless steel ɀ Reflectors (dome & angle) – Krydon TM fiberglass-reinforced polyester * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Standard Finishes: Copper-free aluminum – Corro-free TM powdered epoxy ɀ Krydon – white ɀ Stainless steel guard Ratings (Electrical/Size): Sources/wattage: ɀ Medium Base 70-150W HPS, 70-175W MH ɀ Mogul Base 70-150W HPS, 70-250W MH Voltages: ɀ Medium & Mogul H.I.D. 120V 60Hz Multi-tap (120, 208, 240, 277V 60Hz) Tri-tap (120, 277, 347V 60Hz) 480V 60Hz Other voltages – consult Cooper CrouseHinds Conduit entries: ɀ 3⁄4⍯, 1⍯ NPT – pendant, wall bracket, ceiling ɀ 11⁄4⍯ NPT – stanchion Certification & Compliances: ɀ NEC and CEC: - Class I, Division 1, Groups B (with suffix GB), C, D – All Wattages - Class I, Zone 1 Groups IIB + H2 (with suffix GB), IIB, IIA – All Wattages - Class II, Class III & Simultaneous Presence – (medium base 100 watt max., Mogul Base 175 watt max.) ɀ UL Standards: - 844, Hazardous (Classified) Locations - 1598 Luminaires - 1598A Marine Locations ɀ CSA Standards - C22.2 No. 137 Options: Description Group B suitability BallastGard (HPS only) Instant restrike (Mogul Base only) 70-150W LX HPS Cannot use with BG Option Fused Quartz auxiliary lighting (Mogul Base only) Cannot use with IR option Uses 100W single ended double contract lamp Quartz lamp not included Factory assembled with lamps Suffix to be added to Cat. # GB BG IR S658* QTZ FA Accessories: Description Dome reflector Angle reflector US: 1-866-764-5454 STIBOINFO((CRH:66008com:4L:781)) CH0 0 5 L - 1 CAN: 1-800-265-0502 Cat. # RD739 RA739 Copyright© 2006 Cooper Crouse-Hinds 781 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0782-5 Name: 4L-782 4L DATE: JAN 19 2006 Time: 5:51:21 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ ɀ Cl. I, Div. 1, Groups B(GB suffix),C,D Cl. I, Zone 1 Groups IIB + H2 (With Suffix GB), IIB, IIA ɀ Cl. II, Div. 1, Groups E, F, G; Class III, Simultaneous Presence (100W max) EVLP Low Profile Hazard ȿ Gard® Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 ɀ Medium Base Medium Base Ordering Information Hub Size Watt Pendant With Guard Catalog # Wall Brckt With Guard Catalog # Ceiling With Guard Catalog # EVLPA142071 EVLPA143071 EVLPBX142071 EVLPBX143071 EVLPCX142071 EVLPCX143071 EVLPA142101 EVLPA143101 EVLPBX142101 EVLPBX143101 EVLPCX142101 EVLPCX143101 EVLPA142151 EVLPA143151 EVLPBX142151 EVLPBX143151 EVLPCX142150 EVLPCX143151 Luminaire Body Less Mounting Module & Guard Stanchion With Guard Catalog # Catalog # High Pressure Sodium 3⁄4 70W 1 11⁄4 3⁄4 1 11⁄4 3⁄4 1 11⁄4 100W Pendant Mount 150W EVLP14070 EVLPJ144071 EVLP14100 EVLPJ144101 EVLP14151 EVLPJ144151 Pulse Start Metal Halide 150W 3⁄4 175W 1 11⁄4 3⁄4 1 11⁄4 EVLPA192151-S828 EVLPBX192151-S828 EVLPCX192151-S828 EVLPA193151-S828 EVLPBX193151-S828 EVLPCX193151-S828 EVLP19150-S828 EVLPJ194151-S828 EVLPA192171-S828 EVLPBX192171-S828 EVLPCX192171-S828 EVLPA193171-S828 EVLPBX193171-S828 EVLPCX193171-S828 EVLP19175-S828 EVLPJ194171-S828 Metal Halide 3⁄4 70W †Wall Bracket Mount 1 11⁄4 3⁄4 1 11⁄4 3⁄4 1 11⁄4 100W 175W EVLPA192071 EVLPA193071 EVLPBX192071 EVLPBX193071 EVLPCX192071 EVLPCX193071 EVLPA192101 EVLPA193101 EVLPBX192101 EVLPBX193101 EVLPCX192101 EVLPCX193101 EVLPA192171 EVLPA193171 EVLPBX192171 EVLPBX193171 EVLPCX192171 EVLPCX193171 EVLP19070 EVLPJ194071 EVLP19100 EVLPJ194101 EVLP19175 EVLPJ194171 Complete Catalog Number as follows: 1. Standard Voltage Ballasts – 60HZ NEC/UL Voltage Suffix †Ceiling Mount Multi-tap /MT 120V /120 CEC/CSA (cUL) 480V /480 Tri-tap /TT Optional Voltage Ballasts– 50 Or 60HZ *CEC/CSA (cUL)– CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 600V CWI /600CWI 220V 60HZ /220 Export 220V 50HZ /220 50 2. 150W HPS Luminaires Only ɀ 55V lamps – add suffix ‘‘LX’’ ɀ 100V lamps – add suffix ‘‘CE’’ * CWI Isolated Ballasts are only available for high pressure sodium and 175W metal halide (non pulse start) luminaires. Stanchion Mount †Ceiling and bracket mounts have 4 hubs: 3 are plugged. 782 STIBOINFO((CRH:66008com:4L:782)) CH0 0 5 L - 2 US: 1-866-764-5454 CAN: 1-800-265-0502 120V /120 Copyright© 2006 Cooper Crouse-Hinds 230V 50HZ /230 50 240V 50HZ /240 50 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0783-4 Name: 4L-783 DATE: JAN 19 2006 Time: 5:51:22 PM Operator: JB COLOR: CMYK TCP: 15001 ɀ Cl. I, Div 1, Groups B (GB suffix), C, D Cl. I, Zone 1 Groups IIB + H2 (with suffix GB), IIB, IIA ɀ Cl. II, Div. 1, Groups E, F, G; Class III, Simultaneous Presence (175W max) EVLP Low Profile Hazard ȿ Gard® ɀ Mogul Base Typedriver Name: TS name csm no.: 100 ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 4L Mogul Base Ordering Information Hub Size Watt Pendant With Guard Catalog # Wall Bracket With Guard Catalog # Ceiling With Guard Catalog # EVLPA042071 EVLPA043071 EVLPBX042071 EVLPBX043071 EVLPCX042071 EVLPCX043071 EVLPA042101 EVLPA043101 EVLPBX042101 EVLPBX043101 EVLPCX042101 EVLPCX043101 EVLPA042151 EVLPA043151 EVLPBX042151 EVLPBX043151 EVLPCX042151 EVLPCX043151 Luminaire Body Less Mounting Module & Guard Stanchion With Guard Catalog # Catalog # High Pressure Sodium 3⁄4 70W 1 11⁄4 3⁄4 1 11⁄4 3⁄4 1 11⁄4 100W Pendant Mount 150W EVLP04070 EVLPJ044071 EVLP04100 EVLPJ044101 EVLP04150 EVLPJ044151 Pulse Start Metal Halide 3⁄4 150W 1 11⁄4 3⁄4 1 11⁄4 3⁄4 1 11⁄4 3⁄4 1 11⁄4 175W 200W †Wall Bracket Mount 250W EVLPA092151S828 EVLPBX092151S828 EVLPCX092151S828 EVLPA093151S828 EVLPBX093151S828 EVLPCX093151S828 EVLP09150S828 EVLPJ094151S828 EVLPA092171S828 EVLPBX092171S828 EVLPCX092171S828 EVLPA093171S828 EVLPBX093171S828 EVLPCX093171S828 EVLP09170S828 EVLPJ094171S828 EVLPA092201S828 EVLPBX092201S828 EVLPCX092201S828 EVLPA093201S828 EVLPBX093201S828 EVLPCX093201S828 EVLP09201S828 EVLPJ094201S828 EVLPA092251S828 EVLPBX092251S828 EVLPCX092251S828 EVLPA093251S828 EVLPBX093251S828 EVLPCX093251S828 EVLP09250S828 EVLPJ094251S828 Metal Halide 3⁄4 70W 1 11⁄4 3⁄4 1 11⁄4 3⁄4 1 11⁄4 3⁄4 1 11⁄4 100W 175W 250W †Ceiling Mount EVLPA092071 EVLPA093071 EVLPBX092071 EVLPBX093071 EVLPCX092071 EVLPCX093071 EVLPA092101 EVLPA093101 EVLPBX092101 EVLPBX093101 EVLPCX092101 EVLPCX093101 EVLPA092171 EVLPA093171 EVLPBX092171 EVLPBX093171 EVLPCX092171 EVLPCX093171 EVLPA092251 EVLPA093251 EVLPBX092251 EVLPBX093251 EVLPCX092251 EVLPCX093251 EVLP09070 EVLPJ094071 EVLP09100 EVLPJ094101 EVLP09170 EVLPJ094171 EVLP09250 EVLPJ094251 Complete Catalog Number as follows: 1. Standard Voltage Ballasts – 60HZ NEC/UL Voltage Suffix Multi-tap /MT 120V /120 CEC/CSA (cUL) 480V /480 Tri-tap /TT Optional Voltage Ballasts– 50 Or 60HZ *CEC/CSA (cUL)– CWI Isolated Ballasts Voltage Suffix Stanchion Mount †Ceiling and wall bracket mounts have 4 hubs: 3 are plugged. 208V CWI /208CWI STIBOINFO((CRH:66008com:4L:783)) 600V CWI /600CWI 220V 60HZ /220 Export 220V 50HZ /220 50 230V 50HZ /230 50 240V 50HZ /240 50 2. 150W HPS Luminaires Only ɀ 55V lamps – add suffix ‘‘LX’’ ɀ 100V lamps – add suffix ‘‘CE’’ Example: EVLPA043151/MT-LX * CWI Isolated Ballasts are only available for high pressure sodium and 175W–250W metal halide (non pulse start) luminaires. US: 1-866-764-5454 CH0 0 5 L - 3 240V CWI /240CWI 120V /120 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 783 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0784-1 Name: 4L-784 DATE: JAN 19 2006 Time: 5:51:24 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 EVLP Low Profile Hazard ȿ Gard® 4L Ordering by Components EVLP Luminaires are available in components. A complete luminaire consists of: ɀ Mounting Module ɀ Luminaire Body ɀ Guard, Dome Reflector or Angle Reflector Mounting Modules Type Pendant Conduit 3⁄4 1 3⁄4 1 Use EV22 or EV33 box with EV87 11⁄4 Ceiling & Wall Box Wall Bracket Arm Stanchion Guards Medium Mogul Reflectors Dome Angle Catalog Number EVMP2 EVMP3 EV22 EV33 EV87 EVMJ4 EV511 EV512 RD739 RA739 Pendant EVMP2 EVMP3 Ceiling EV22 EV33 Stanchion EVMJ4 Ceiling EV22 EV33 Wall Bracket EV87 & EV22 or EV33 Luminaire Body EVLP0 Series – H.I.D. Mogul Lamp EVLP1 Series – H.I.D. Medium Lamp (Refer to Ordering Information Page for Complete Catalog No.) Guards EV511 EV512 784 STIBOINFO((CRH:66008com:4L:784)) CH0 0 5 L - 4 US: 1-866-764-5454 Dome Reflector RD739 CAN: 1-800-265-0502 Angle Reflector RA739 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0785-1 Name: 4L-785 DATE: JAN 19 2006 Time: 5:51:26 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Temperature Performance Data EVLP Low Profile Hazard ȿ Gard® 4L Medium Base Lamp Luminaires Maximum Ambient High Pressure Sodium Metal Halide (including pulse start) Class I, Group B (w/GB suffix) Groups C, D 40°C 55°C T5 T4A T4A T4A T4 T3C T5 T4A T3C T3C T3C T3B T3C T3B Watts 70W 100W 150W 70W 100W 150W 175W 65°C T4A T4 – T4A – – – Class II, Groups E, F, G Class III Simultaneous Presence 40°C T4A T4 – T4 – – – Supply Wire °C 90°C 90°C 90°C 85°C 90°C 90°C 90°C 65°C T5 – – T5 T4A – – – – Class II, Groups E, F, G Class III Simultaneous Presence 40°C T5 T4A T4 T5 T4A T3C T3C – – Supply Wire °C 90°C 90°C 90°C 85°C 90°C 90°C 90°C 90°C 90°C Mogul Base Lamp Luminaires Maximum Ambient High Pressure Sodium Metal Halide (including pulse start) Watts 70W 100W 150W 70W 100W 150W 175W 200W 250W Class I, Group B (w/GB suffix) Groups C, D 40°C 55°C T6 T5 T5 T4A T4A T4 T6 T5 T5 T4A T4 T3C T4 T3C T3C – T3C – US: 1-866-764-5454 STIBOINFO((CRH:66008com:4L:785)) CH0 0 5 L - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 785 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0786-1 Name: 4L-786 4L 100: DATE: JAN 19 2006 Time: 5:51:27 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 EVLP Low Profile Hazard ȿ Gard® Dimensions and Weights Dimensions (inches): A 13.92 15.69 Medium Base Mogul Base B 12.73 14.69 C 16.50 18.25 D 16.71 18.46 E 20.59 22.34 Weights (lbs) Source High Pressure Sodium Metal Halide Watts 70 100 150 70 100 150 175 200 250 Add Mounting Modules: Pendant Ceiling Bracket Stanchion Add For Reflectors RA739 RD739 Deduct for Wire Guard 786 STIBOINFO((CRH:66008com:4L:786)) CH0 0 5 L - 6 US: 1-866-764-5454 Luminaire w/guard Medium 34 36 36.5 33.5 34.5 36 36 – – Mogul 36.5 38.5 39 36 37 38.5 38.5 40.5 40.5 1 2 4.5 2.5 1 2 4.5 2.5 1 1 0.5 1 1 0.5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds F 19.36 21.30 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0787-1 Name: 4L-787 100: DATE: JAN 19 2006 Time: 5:51:29 PM Operator: JB COLOR: CMYK TCP: 15001 Photometric Data EVLP Low Profile Hazard ȿ Gard® Typedriver Name: TS name csm no.: 100 4L Medium Base Medium Base Luminaire with Globe and Guard EVLPA143151 Lamp: 150W/B17 High Pressure Sodium (HPS) CANDELAS Mid-Zone Angle Candelas 0 1592 5 1005 15 952 25 1410 35 1194 45 1069 55 1252 65 1240 75 1442 85 1541 95 1571 105 789 115 33 125 6 Medium Base Luminaire with Globe and Dome Reflector (Less Guard) EVLPA143150RD Lamp: 150W/B17 High Pressure Sodium (HPS) CANDELAS US: 1-866-764-5454 STIBOINFO((CRH:66008com:4L:787)) CH0 0 5 L - 7 Mid-Zone Angle Candelas 0 3019 5 2525 15 2645 25 2718 35 2349 45 2023 55 1967 65 1350 75 628 85 200 95 53 105 1 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 787 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0788-1 Name: 4L-788 4L 100: DATE: JAN 19 2006 Time: 5:51:31 PM Operator: JB COLOR: CMYK TCP: 15001 Photometric Data EVLP Low Profile Hazard ȿ Gard® Medium and Mogul Base Medium Base Luminaire with Globe and 30° Angle Reflector (Less Guard) EVLPA143150RA Lamp: 150W/B17 High Pressure Sodium (HPS) CANDELAS Degrees Front Side Back 0 2722 2722 2722 5 2647 2026 1785 15 3047 2283 1754 25 2739 2457 1590 35 2709 1857 882 45 2739 1729 308 55 2483 1159 21 65 2421 790 0 75 2288 205 0 85 934 82 0 95 257 0 31 105 62 0 0 115 0 0 0 125 0 0 0 135 0 0 0 145 0 0 0 155 0 0 0 165 0 0 0 175 0 0 0 180 0 0 0 Mogul Base Luminaire with Globe and Guard EVLPA043151 Lamp: 150W/E231⁄2 High Pressure Sodium (HPS) CANDELAS Mid-Zone Angle Candelas 0 1944 5 1541 15 1167 25 1159 35 981 45 1035 55 1090 65 1348 75 1566 85 1619 95 1612 105 1226 115 265 125 19 135 10 145 7 155 6 165 0 175 0 180 0 788 STIBOINFO((CRH:66008com:4L:788)) CH0 0 5 L - 8 US: 1-866-764-5454 CAN: 1-800-265-0502 ZONAL LUMENS With Zone Lumens 0-10 140 10-20 337 20-30 524 30-40 620 40-50 798 50-60 1030 60-70 1353 70-80 1640 80-90 1754 90-100 1749 100-110 1277 110-120 306 120-130 19 130-140 8 140-150 5 150-160 3 160-170 0 170-180 0 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0789-1 Name: 4L-789 100: DATE: JAN 19 2006 Time: 5:51:32 PM Operator: JB COLOR: CMYK TCP: 15001 Photometric Data EVLP Low Profile Hazard ȿ Gard® Typedriver Name: TS name csm no.: 100 4L Mogul Base Mogul Base Luminaire with Globe and Dome Reflector (Less Guard) EVLPA043150RD Lamp: 150W/E231⁄2 High Pressure Sodium (HPS) CANDELAS Mid-Zone Angle Candelas 0 3568 5 3194 15 3097 25 3052 35 2420 45 2290 55 2044 65 1734 75 437 85 113 95 46 105 84 115 10 125 3 135 0 145 0 155 0 165 0 175 0 180 0 ZONAL LUMENS Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Lumens 299 882 1379 1527 1767 1880 1662 480 127 49 81 14 4 0 0 0 0 0 Mogul Base Luminaire with Globe and 30° Angle Reflector (Less Guard) EVLPA043150RA Lamp: 150W/E231⁄2 High Pressure Sodium (HPS) CANDELAS Degrees 0 5 15 25 35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 180 Front Side Back 3300 3300 3300 3369 3054 2446 3468 2553 1856 3299 2508 1526 2874 2189 1128 3150 2111 402 2920 1846 85 2907 2292 4 2880 1309 12 2454 80 19 1776 9 77 894 11 142 266 12 14 73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ZONAL LUMENS Zone Lumens 0-10 278 10-20 760 20-30 1138 30-40 1348 40-50 1502 50-60 1388 60-70 1317 70-80 1134 80-90 683 90-100 242 100-110 105 110-120 22 120-130 0 130-140 0 140-150 0 150-160 0 160-170 0 170-180 0 US: 1-866-764-5454 STIBOINFO((CRH:66008com:4L:789)) CH0 0 5 L - 9 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 789 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0790-1 Name: 4L-790 4L 100: DATE: JAN 19 2006 Time: 5:51:34 PM Operator: JB COLOR: CMYK TCP: 15001 Photometric Data EVLP Low Profile Hazard ȿ Gard® Mogul Base Mogul Base Luminaire with Globe and Guard EVLPA093171 Lamp: 175W/ED28 Metal Halide (MH) CANDELAS Mid-Zone Angle Candelas 0 2439 5 1750 15 1089 25 1017 35 915 45 917 55 1035 65 1229 75 1337 85 1359 95 1335 105 1196 115 390 125 24 135 12 145 9 155 0 165 0 175 0 180 0 ZONAL LUMENS Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Lumens 158 313 464 563 732 922 1128 1377 1473 1452 1257 427 23 9 3 0 0 0 Mogul Base Luminaire with Globe and Dome Reflector (Less Guard) EVLPA093170RD Lamp: 175W/ED28 Metal Halide (MH) CANDELAS Mid-Zone Angle Candelas 0 3941 5 3241 15 2651 25 2777 35 2219 45 2047 55 1880 65 1693 75 432 85 102 95 14 105 99 115 13 125 3 135 0 145 0 155 0 165 0 175 0 180 0 790 STIBOINFO((CRH:66008com:4L:790)) CH0 0 5 L 1 0 US: 1-866-764-5454 CAN: 1-800-265-0502 ZONAL LUMENS Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Lumens 300 763 1249 1399 1594 1671 1466 466 121 20 88 16 2 0 0 0 0 0 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0791-1 Name: 4L-791 100: DATE: JAN 19 2006 Time: 5:51:36 PM Operator: JB COLOR: CMYK TCP: 15001 Photometric Data EVLP Low Profile Hazard ȿ Gard® Typedriver Name: TS name csm no.: 100 4L Mogul Base Mogul Base Luminaire with Globe and 30° Angle Reflector (Less Guard) EVLPA093170RA Lamp: 175W/ED28 Metal Halide (MH) CANDELAS Degrees 0 5 15 25 35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 180 Front Side Back 3765 3765 3765 2986 2903 3379 2958 2301 2235 2678 2119 1744 2493 1859 1343 2736 1747 378 2804 1582 81 2729 871 3 2828 277 8 2378 63 16 2048 15 25 1010 10 24 274 10 139 75 11 18 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ZONAL LUMENS Zone Lumens 0-10 285 10-20 689 20-30 1003 30-40 1229 40-50 1337 50-60 1232 60-70 1131 70-80 1035 80-90 659 90-100 228 100-110 109 110-120 26 120-130 0 130-140 0 140-150 0 150-160 0 160-170 0 170-180 0 US: 1-866-764-5454 STIBOINFO((CRH:66008com:4L:791)) CH0 0 5 L 1 1 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 791 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0792-6 Name: 4L-792 4L 100: DATE: JAN 19 2006 Time: 5:51:37 PM Operator: RB EVM Hazard ȿ Gard® H.I.D. Luminaires COLOR: CMYK TCP: 15001 ɀ Cl. I, Div. 1 Groups B (GB suffix),C,D Cl. I, Zone 1 Groups IIB + H2 (with suffix – GB), IIB IIA ɀ Cl. II, Div. 1, Groups E,F,G; Class III, Mogul Base Simultaneous Presence (175W max) Factory Sealed (Groups C.D) ɀ Typedriver Name: TS name csm no.: 100 ɀ Paint Spray (100W max) ɀ Marine & Wet Locations ɀ 3,3R,4,4X; IP66 Application: Hazard ȿ Gard® luminaires are used in: ɀ heavy process industries where flammable or explosive vapors, gases or combustible dusts are present ɀ hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired ɀ petroleum refineries, chemical, petrochemical and other heavy process industry facilities ɀ paint spray facilities ɀ hazardous locations requiring elevated ambient capability Features: ɀ Luminaire is factory wired; power is fed through ‘‘wireless’’ connection block which serves as a mechanical seal between conduit and ballast compartments, eliminating the need for an external, field installed seal. The result is fast, easy installation. ɀ Dome and 30° angle reflectors made of Krydon® material – won’t rust, corrode, dent, chip or peel (order separately – page 796). ɀ High bay reflectors of Alzak® aluminum for high wattage applications ɀ Internally fluted glass globes reduce glare and provide comfortable viewing light. ɀ Wide range of light sources and wattages to meet specific lighting needs – 50 – 400W high pressure sodium (HPS); 100 – 400W mercury vapor (MV); 70 – 400W metal halide (MH). ɀ High power factor (90% +) ballasts reduce power costs – allow more luminaires per circuit. ɀ Four mounting arrangements to suit any lighting layout – pendant, ceiling, wall bracket and stanchion. ɀ Paint spray booth suitability on 50 to 100 watt luminaires provides efficient, economical H.I.D. lighting for areas where paint residue may accumulate on luminaires. ɀ Elevated ambient capability permits reliable operation at high ambient temperature. Selected luminaires are suitable for ambient temperature up to 75°C. ɀ Integral ballasts – separate ballasts are not required. Lowest installed cost. ɀ Factory sealed, porcelain, mogul base socket. Standard Materials: ɀ Mounting modules, cover, ballast housing, guard, globe ring – copper-free aluminum ɀ Globe – heat and impact resistant glass ɀ Exterior hardware – stainless steel ɀ Lamp socket – porcelain with stainless steel screw shell ɀ Reflectors – dome and angle: Krydon fiberglass-reinforced polyester material; high bay: Alzak aluminum Alzak is a registered trademark of ALCOA. * IR and BG options cannot be used together. ** Can be used with BG option. 刁 CSA Certified luminaires are not available with multi-tap ballast or S658 fuse option. † When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. 792 STIBOINFO((CRH:66008com:4L:792)) CH0 0 5 L 1 2 Standard Finishes: ɀ Copper-free aluminum – epoxy powder coat ɀ Krydon – high reflectance white ɀ Alzak – natural (anodized) Options: ɀ Fused – to protect ballast and capacitor against abnormal line conditions. Add suffix S658 to Cat. No.# † ɀ Instant restrike – enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage. It has no effect on the warm-up period of a cold lamp (50-150W LX HPS only). Add suffix IR to Cat. No.* ɀ Quartz auxiliary lighting – quartz lamp comes to full brightness instantly upon restoration of power to provide emergency illumination during the normal restrike period of the H.I.D. lamp (for use with ED28 lamp). Add suffix QTZ to Cat. No.** (Note: Quartz lamp not included; use 100 W single-ended lamp – Q100DC, Q100CL/DC, or 100Q/CL/DC.) ɀ Ballast ȿ Gard – to eliminate the normally continuous high voltage pulsing in the event of a cycling lamp, inoperative lamp, or no lamp in the socket extending the life of the ballast.(For use with 50-400W HPS lamps.) Add suffix BG to Cat. No.* ɀ Group B suitability – luminaires suitable for use in Class I, Group B hazardous (classified) locations. Add suffix GB to Cat. No. US: 1-866-764-5454 CAN: 1-800-265-0502 ɀ Hazard ȿ Gard® supplied with trunnion arm for floodlighting applications. For use on pendant mount luminaires only. Add suffix S812 to Cat. No. – See Floodlight Section Size Ranges: ɀ 3⁄4⍯, 1⍯ and 11⁄4⍯ hubs (see ordering information – pages 793 to 795) Electrical Rating Ranges: ɀ 120, 208, 240, 277, 347, 480, 600, multitap#. ɀ 50 to 400 watts Certifications and Compliances: ɀ NEC and CEC: Class I, Division 1, Groups B (with suffix GB), C,D Class I, Zone 1, Groups IIB + H2 (with suffix GB), IIB, IIA 100W max – Paint Spray Suitability 175W max – Class II, Class III, + Simultaneous Presence ɀ UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards: C22.2 No. 137 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0793-2 Name: 4L-793 DATE: JAN 19 2006 50-400W EVM Hazard ȿ Gard®H.I.D. Luminaires COLOR: CMYK ɀ Cl. I, Div. 1, Groups B(GB suffix),C,D Cl. I, Zone 1 Groups IIB + H2 (with suffix GB), IIB, IIA ɀ Cl. II, Div. 1, Groups E,F,G; Class III, Simultaneous Presence (175W max) ɀ Mogul Base Factory Sealed (Groups C,D) Hub Watts Size Time: 5:51:38 PM Operator: RB Pendant Luminaires Without With Guard Guard Cat. # Cat. # TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Paint Spray (100W max) ɀ Marine & Wet Locations ɀ 3,3R,4,4X; IP66 Wall Bracket Luminaires Without With Guard Guard Cat. # Cat. # Ceiling Luminaires Without With Guard Guard Cat. # Cat. # EVMBX42050 EVMBX43050 EVMCX42050 EVMCX42051 EVMCX43050 EVMCX43051 4L Stanchion Luminaires (25°) Without With Guard Guard Cat. # Cat. # High Pressure Sodium 50 3⁄4 1 11⁄4 EVMA42050 EVMA43050 70 3⁄4 EVMA42070 EVMA43070 1 11⁄4 EVMA42051 EVMA43051 EVMA42071 EVMA43071 EVMBX42070 EVMBX43070 EVMBX42051 EVMBX43051 EVMBX42071 EVMBX43071 3⁄4 1 11⁄4 EVMA42100 EVMA43100 EVMA42101 EVMA43101 EVMBX42100 EVMBX43100 EVMBX42101 EVMBX43101 EVMCX42100 EVMCX42101 EVMCX43100 EVMCX43101 150 3⁄4 EVMA42150 EVMA43150 EVMA42151 EVMA43151 EVMBX42150 EVMBX43150 EVMBX42151 EVMBX43151 EVMCX42150 EVMCX42151 EVMCX43150 EVMCX43151 200 3⁄4 1 11⁄4 250 3⁄4 1 11⁄4 400 3⁄4 1 11⁄4 EVMA42200 EVMA43200 EVMA42250 EVMA43250 EVMA42400 EVMA43400 EVMA42201 EVMA43201 EVMA42251 EVMA43251 EVMA42401 EVMA43401 EVMBX42200 EVMBX43200 EVMBX42250 EVMBX43250 EVMBX42400 EVMBX43400 EVMBX42201 EVMBX43201 EVMBX42251 EVMBX43251 EVMBX42401 EVMBX43401 EVMJ44051 EVMJ44070 EVMJ44071 EVMJ44100 EVMJ44101 EVMJ44150 EVMJ44151 EVMJ44200 EVMJ44201 EVMJ44250 EVMJ44251 EVMJ44400 EVMJ44401 EVMCX42070 EVMCX42071 EVMCX43070 EVMCX43071 100 1 11⁄4 EVMJ44050 EVMCX42200 EVMCX42201 EVMCX43200 EVMCX43201 EVMCX42250 EVMCX42251 EVMCX43250 EVMCX43251 EVMCX42400 EVMCX42401 EVMCX43400 EVMCX43401 Complete the Catalog Number by Adding Voltage and Options Suffixes as Follows: 1. Standard Voltage Ballasts – 60HZ NEC/UL Voltage Suffix Multi-tap /MT 120V /120 480V /480 Optional Voltage Ballasts – 50 or 60HZ CEC/CSA (cUL)– CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 480V CWI /480CWI 600V CWI /600CWI 220V 60HZ /220 CEC/CSA (cUL) Tri-tap /TT 120V /120 Export 220V 50HZ /220 50 230V 50HZ /230 50 240V 50HZ /240 50 2. 150W HPS Luminaires, 55V Lamps is Standard, for 100V lamps - Add suffix ‘‘CE’’ 3. Options - Add the Required Options Suffixes from page 792, in Alpha-numeric Order US: 1-866-764-5454 STIBOINFO((CRH:66008com:4L:793)) CH0 0 5 L 1 3 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 793 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0794-3 Name: 4L-794 DATE: JAN 19 2006 Time: 5:51:40 PM Operator: JB Factory Sealed (Groups C,D) Hub Watts Size Pendant Luminaires Without With Guard Guard Cat. # Cat. # TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div. 1, Groups B (GB suffix),C,D Cl. I, Zone 1 Groups IIB + H2 (with suffix GB), IIB, IIA ɀ Cl. II, Div. 1, Groups E,F,G; Class III, Simultaneous Presence (175W max) 70-400W EVM Hazard ȿ Gard® H.I.D Luminaires 4L COLOR: CMYK Wall Bracket Luminaires Without With Guard Guard Cat. # Cat. # Ceiling Luminaires Without With Guard Guard Cat. # Cat. # EVMCX92150-S828 EVMCX93150-S828 Typedriver Name: TS name csm no.: 100 Paint Spray (100W max) Marine & Wet Locations ɀ 3,3R,4,4X; IP66 Stanchion Luminaires (25°) Without With Guard Guard Cat. # Cat. # Pulse Start Metal Halide 150 3⁄4 1 11⁄4 EVMA92150-S828 EVMA93150-S828 EVMA92151-S828 EVMA93151-S828 EVMBX92150-S828 EVMBX93150-S828 EVMBX92151-S828 EVMBX93151-S828 175 3⁄4 EVMA92170-S828 EVMA93170-S828 EVMA921701-S828 EVMA931701-S828 EVMBX92170-S828 EVMBX93170-S828 EVMBX921701-S828 EVMCX92170-S828 EVMBX931701-S828 EVMCX93170-S828 EVMCX921701-S828 EVMCX931701-S828 EVMA92200-S828 EVMA93200-S828 EVMA92201-S828 EVMA93201-S828 EVMBX92200-S828 EVMBX93200-S828 EVMBX92201-S828 EVMBX93201-S828 EVMCX92200-S828 EVMCX93200-S828 EVMCX92201-S828 EVMCX93201-S828 EVMA92250-S828 EVMA93250-S828 EVMA92251-S828 EVMA93251-S828 EVMBX92250-S828 EVMBX93250-S828 EVMBX92251-S828 EVMBX93251-S828 EVMCX92250-S828 EVMCX93250-S828 EVMCX92251-S828 EVMCX93251-S828 EVMA92320-S828 EVMA93320-S828 EVMA92321-S828 EVMA93321-S828 EVMBX92320-S828 EVMBX93320-S828 EVMBX92321-S828 EVMBX93321-S828 EVMCX92320-S828 EVMCX93320-S828 EVMCX92321-S828 EVMCX93321-S828 EVMA92400-S828 EVMA93400-S828 EVMA92401-S828 EVMA93401-S828 EVMBX92400-S828 EVMBX93400-S828 EVMBX92401-S828 EVMBX93401-S828 EVMCX92400-S828 EVMCX93400-S828 EVMCX92401-S828 EVMCX93401-S828 1 11⁄4 200 3⁄4 1 11⁄4 250 3⁄4 1 11⁄4 320 3⁄4 400 1 11⁄4 3⁄4 1 11⁄4 EVMCX92151-S828 EVMCX93151-S828 EVMJ94150-S828 EVMJ94151-S828 EVMJ94170-S828 EVMJ94171-S828 EVMJ94200-S828 EVMJ94201-S828 EVMJ94250-S828 EVMJ94251-S828 EVMJ94320-S828 EVMJ94321-S828 EVMJ94400-S828 EVMJ94401-S828 EVMJ94070 EVMJ94071 EVMJ94100 EVMJ94101 EVMJ94170 EVMJ94171 EVMJ94250 EVMJ94251 EVMJ94400 EVMJ94401 Metal Halide 70 100 175 250 400 3⁄4 1 11⁄4 3⁄4 1 11⁄4 3⁄4 1 11⁄4 3⁄4 1 11⁄4 3⁄4 1 11⁄4 EVMA92070 EVMA93070 EVMA92071 EVMA93071 EVMBX92070 EVMBX93070 EVMBX92071 EVMBX93071 EVMCX92070 EVMCX93070 EVMCX92071 EVMCX93071 EVMA92100 EVMA93100 EVMA92101 EVMA93101 EVMBX92100 EVMBX93100 EVMBX92101 EVMBX93101 EVMCX92100 EVMCX93100 EVMCX92101 EVMCX93101 EVMA92170 EVMA93170 EVMA92171 EVMA93171 EVMBX92170 EVMBX93170 EVMBX92171 EVMBX93171 EVMCX92170 EVMBX93170 EVMCX92171 EVMCX93171 EVMA92250 EVMA93250 EVMA92251 EVMA93251 EVMBX92250 EVMBX93250 EVMBX92251 EVMBX93251 EVMCX92250 EVMCX93250 EVMCX92251 EVMCX93251 EVMA92400 EVMA93400 EVMA92401 EVMA93401 EVMBX92400 EVMBX93400 EVMBX92401 EVMBX93401 EVMCX92400 EVMCX93400 EVMCX92401 EVMCX93401 Complete the Catalog Number by Adding Voltage and Options Suffixes as Follows: 1. Standard Voltages Ballasts – 60HZ NEC/UL Voltage Suffix Multi-tap /MT Dual-Tap /DT 120V /120 480V /480 CEC/CSA (cUL) Tri-tap /TT Optional Voltage Ballasts – 50 or 60HZ CEC/CSA (cUL)– CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 600V CWI /600CWI 220V 60HZ /220 Dual-Tap /DT Export 220V 50HZ /220 50 230V 50HZ /230 50 2. 150W HPS Luminaires, 55V Lamps is Standard, for 100V lamps - Add suffix ‘‘CE’’ 3. Options - Add the Required Options Suffixes from page 792, In Alpha-numeric Order * CWI Isolated Ballasts are only available for 175W–400W metal halide (non pulse start) luminaires. 794 STIBOINFO((CRH:66008com:4L:794)) CH0 0 4 L 1 4 US: 1-866-764-5454 CAN: 1-800-265-0502 120V /120 Copyright© 2006 Cooper Crouse-Hinds 240V 50HZ /240 50 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0795-2 Name: 4L-795 100: DATE: JAN 19 2006 COLOR: CMYK ɀ ɀ ɀ ɀ Cl. I, Div. 1, Groups B (GB suffix),C,D Cl. I, Zone 1 Groups IIB + H2 (with suffix GB), IIB, IIA ɀ Cl. II, Div. 1, Groups E,F,G; Class III, Simultaneous Presence (175W max) 70-400W EVM Hazard ȿ Gard® H.I.D Luminaires Factory Sealed (Groups C,D) Hub Watts Size Time: 5:51:41 PM Operator: RB Pendant Luminaires Without With Guard Guard Cat. # Cat. # TCP: 15001 Typedriver Name: TS name csm no.: 100 Paint Spray (100W max) Marine & Wet Locations ɀ 3,3R,4,4X; IP66 Wall Bracket Luminaires Without With Guard Guard Cat. # Cat. # Ceiling Luminaires Without With Guard Guard Cat. # Cat. # 4L Stanchion Luminaires (25°) Without With Guard Guard Cat. # Cat. # Mercury Vapor 100 175 250 400 3⁄4 1 11⁄4 3⁄4 1 11⁄4 3⁄4 1 11⁄4 3⁄4 1 11⁄4 EVMA82100 EVMA83100 EVMA82101 EVMA83101 EVMBX82100 EVMBX83100 EVMBX82101 EVMBX83101 EVMCX82100 EVMCX82101 EVMCX83100 EVMCX83101 EVMA82170 EVMA83170 EVMA82171 EVMA83171 EVMBX82170 EVMBX83170 EVMBX82171 EVMBX83171 EVMCX82170 EVMCX82171 EVMCX83170 EVMCX83171 EVMA82250 EVMA83250 EVMA82251 EVMA83251 EVMBX82250 EVMBX83250 EVMBX82251 EVMBX83251 EVMCX82250 EVMCX82251 EVMCX83250 EVMCX83251 EVMA82400 EVMA83400 EVMA82401 EVMA83401 EVMBX82400 EVMBX83400 EVMBX82401 EVMBX83401 EVMCX82400 EVMCX82401 EVMCX83400 EVMCX83401 EVMJ84100 EVMJ84101 EVMJ84170 EVMJ84171 EVMJ84250 EVMJ84251 EVMJ84400 EVMJ84401 Complete the Catalog Number by Adding Voltage and Options Suffixes as Follows: 1. Standard Voltage Ballasts – 60HZ NEC/UL Voltage Suffix Multi-tap /MT Dual-Tap /DT 120V /120 480V /480 Optional Voltage Ballasts – 50 or 60HZ CEC/CSA (cUL)– CWI Isolated Ballasts Voltage Suffix 208V CWI /208CWI 240V CWI /240CWI 480V CWI /480CWI 600V CWI /600CWI 220V 60HZ /220 CEC/CSA (cUL) Tri-tap /TT Dual-Tap /DT 120V /120 Export 220V 50HZ /220 50 230V 50HZ /230 50 240V 50HZ /240 50 2. Options - Add the Required Options Suffixes from page 792, in Alpha-numeric Order US: 1-866-764-5454 STIBOINFO((CRH:66008com:4L:795)) CH0 0 4 L 1 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 795 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0796-1 Name: 4L-796 4L DATE: JAN 19 2006 Time: 5:51:43 PM Operator: JB EVM Hazard ȿ Gard® H.I.D. Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Accessories and Temperature Performance Data Reflectors Dome 30° Angle High Bay Type Cat. # Dome 30° Angle High Bay RD739 RA739 EV3912 Temperature Performance Data Maximum Ambient Watts 40°C 55°C High Pressure Sodium 50 T6 T6 70 T6 T6 100 T5 T5 150 T4A T4A 200 T4A T4A 250 T4 T3C 400 T3C — Mercury Vapor 100 T5 T5 175 T4A T4 250 T3C T3B 400 T3 — Metal Halide (Including Pulse Start) 70 T6 T6 100 T5 T5 150 T4A T4 175 T4A T4 200 T4 T3C 250 T4 T3C 320 T3A — 400 T3A — 796 STIBOINFO((CRH:66008com:4L:796)) CH0 0 5 L 1 5 75°C Class II (E,F,G) 40°C Simultaneous Presence 40°C Paint Spray Booth 40°C Supply Wire °C T6 T5 T4A T4 T4 — — T5 T4A T4A — — — — T4 T4 T4 T3C — — — T4 T4 T4 T3C — — — T4A T4A T4A — — — — 90 90 90 90 90 90 90 T4A T4 — — T4A — — — T3C T3C — — T3C T3C — — T4A — — — 90 90 90 90 T5 T4A T4 T4 — — — — T3 T3 — — — — — — T3C T3C T3C T3C — — — — T3C T3C T3C T3C — — — — T4A T4A — — — — — — 90 90 90 90 90 90 90 90 Class I 65°C US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0797-1 Name: 4L-797 100: DATE: JAN 19 2006 Time: 5:51:44 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 EVM Hazard ȿ Gard® H.I.D. Luminaires 4L Dimensions and Weights Dimensions Luminaire Net Weights: H.I.D. Source High Pressure Sodium Mercury Vapor Lamp Watts 50 70 100 150 (55V) 150 (100V) 200 250 400 Luminaire Only with Globe and Guard (Lbs.) 40 40 44 45 44 46 46 55 100 175 250 400 38 41 43 49 70 39 100 39 175 42 250 43 400 51 Add for Mounting Modules: Pendant 1 lb. Bracket Ceiling 2 lbs. Stanchion Metal Halide Deduct: Guard 41⁄4 lbs. 21⁄4 lbs. 11⁄2 lbs. Add for Reflectors: RD739 13⁄4 lbs. RA739 2 lbs. EV3912 21⁄2 lbs. Guard EV503 EV5140 All luminaires with 100, 175, 250W MV QTZ option and 50, 70, 100, 150W HPS 200, 250, 400W HPS 70, 100, 175, 250W MH 400W MV & MH a b f g 26 275⁄16 281⁄4 251⁄16 277⁄8 2813⁄16 301⁄8 311⁄16 24 2415⁄16 261⁄4 273⁄16 2211⁄16 241⁄8 251⁄4 261⁄8 Type EVMA EVMBX EVMCX EVMJ ‡ Suitable for Class III when listed for Class II, Group G. ɍ See Options listing. US: 1-866-764-5454 STIBOINFO((CRH:66008com:4L:797)) CH0 0 5 L 1 6 All – Reflectors High Dome – Bay – c d 237⁄8 267⁄16 2611⁄16 293⁄4 2213⁄16 253⁄8 253⁄8 2711⁄16 CAN: 1-800-265-0502 30° Angle – e 289⁄16 313⁄8 271⁄2 283⁄4 Copyright© 2006 Cooper Crouse-Hinds 797 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: JOB: CRMAIN06-0798-2 Name: 4L-798 4L 100: DATE: JAN 19 2006 Time: 5:51:45 PM Operator: RB EVM Hazard ȿ Gard® H.I.D. Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Lamp: 100W/E-231⁄2 mercury vapor – (MV) Total bare lamp lumens: 4200 Lamp: 100W/E231⁄2 mercury vapor – (MV) Total bare lamp lumens: 4200 To determine number and placement of luminaires, see Lighting Selector guide, pages 665 to 689 To determine number and placement of luminaires, see Lighting Selector guide, pages 665 to 689 Luminaire With Globe and Without Guard Luminaire With Globe, Dome Reflector and Without Guard NOTE: Photometric data was developed using a 100 watt diffuse mercury vapor lamp (4,200 lumens). For other diffuse lamps, use the following conversion factors (multipliers): 175W MV – 2.05; 70W MH – 1.33; 100W MH – 1.85; 175W MH (metal halide) – 3.33. Multipliers are for use with candela curve only. NOTE: Photometric data was developed using a 100 watt diffuse mercury vapor lamp (4,200 lumens). For other diffuse lamps, use the following conversion factors (multipliers): 175W MV – 2.05; 70W MH – 1.33; 100W MH – 1.85; 175W MH (metal halide) – 3.33. Multipliers are for use with candela curve only. Luminaire spacing ratio is 1.30. Luminaire spacing ratio is 1.25. Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 % Reflectance Eff. Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 .694 .584 .503 .644 .516 .428 .600 .459 .369 .660 .556 .479 .615 .493 .410 .572 .441 .355 .596 .501 .432 .559 .450 .375 .526 .405 .328 .538 .451 .389 .509 .410 .342 .481 .373 .302 .485 .405 .349 .461 .371 .310 .439 .341 .277 .410 .313 .251 Room Cavity Ratio 6 7 8 .347 .312 .282 .273 .241 .214 .220 .192 .165 .331 .298 .270 .262 .231 .206 .211 .184 .160 .300 .272 .246 .241 .212 .190 .197 .171 .149 .272 .245 .225 .222 .196 .175 .183 .158 .139 .246 .224 .203 .202 .180 .160 .168 .147 .129 .148 .128 .111 798 STIBOINFO((CRH:66008com:4L:798)) CH0 0 5 L 1 9 98: 4 5 .439 .361 .302 .418 .347 .291 .377 .317 .270 .339 .290 .249 .305 .263 .228 .204 .386 .311 .253 .368 .297 .244 .334 .274 .227 .302 .250 .210 .271 .223 .193 .171 9 .259 .192 .147 .248 .185 .143 .227 .172 .134 .207 .158 .124 .188 .146 .115 .099 10 .230 .166 .125 .220 .162 .121 .203 .150 .113 .185 .138 .105 .169 .127 .096 .082 US: 1-866-764-5454 CAN: 1-800-265-0502 % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 % Reflectance Eff. Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 .715 .637 .570 .688 .596 .521 .665 .562 .483 .699 .624 .560 .675 .586 .514 .652 .556 .478 .668 .598 .539 .648 .568 .500 .631 .540 .468 .640 .576 .519 .624 .550 .487 .609 .527 .459 .615 .554 .502 .602 .533 .474 .589 .514 .450 .575 .500 .436 Room Cavity Ratio 6 7 8 .414 .375 .340 .358 .319 .286 .318 .282 .247 .407 .369 .335 .354 .315 .283 .315 .278 .246 .394 .358 .325 .347 .309 .278 .312 .275 .244 .383 .346 .316 .340 .304 .273 .308 .272 .242 .371 .338 .307 .333 .299 .268 .304 .269 .240 .292 .257 .227 Copyright© 2006 Cooper Crouse-Hinds 4 5 .509 .455 .413 .500 .450 .410 .481 .438 .404 .465 .428 .398 .450 .418 .391 .377 .458 .401 .359 .448 .396 .356 .434 .388 .353 .420 .379 .348 .407 .372 .343 .329 9 .313 .259 .222 .308 .256 .221 .299 .252 .219 .292 .248 .217 .284 .244 .215 .204 10 .275 .222 .187 .271 .222 .187 .264 .217 .185 .257 .214 .183 .251 .210 .181 .170 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0799-2 Name: 4L-799 100: DATE: JAN 19 2006 EVM Hazard ȿ Gard® H.I.D. Luminaires Time: 5:51:46 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Isofootcandle Chart: Luminaire With Globe and 30° Angle Reflector, Without Guard 4L Lamp: 150W/E-231⁄2 high pressure sodium (HPS) Total bare lamp lumens: 16,000 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. Luminaire With Globe and Without Guard NOTE: Photometric data was developed using a 150 watt clear high pressure sodium lamp (16,000 lumens). For other clear lamps, use the following conversion factors (multipliers): 50W HPS – .25; 70W HPS – .40; 100W HPS – .59. Multipliers are for use with candela curve only. Luminaire spacing ratio is 0.80. Coefficient of Utilization Effective Floor Cavity Reflectance 20% Lamp: 100W/E-231⁄2 diffuse mercury vapor (MV) Total bare lamp lumens: 4200 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. Illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights. Height (Ft.) 6 7 8 Factor 2.78 2.04 1.56 Height (Ft.) 9 11 12 US: 1-866-764-5454 STIBOINFO((CRH:66008com:4L:799)) CH0 0 5 L 2 0 Factor 1.23 0.83 0.70 CAN: 1-800-265-0502 % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 % Reflectance Eff. Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 .695 .579 .494 .644 .509 .417 .599 .450 .356 .659 .549 .469 .613 .484 .397 .570 .431 .341 .592 .491 .419 .555 .439 .360 .522 .393 .312 .531 .438 .373 .502 .396 .325 .474 .358 .284 .476 .390 .331 .451 .355 .291 .429 .325 .257 .399 .295 .230 Room Cavity Ratio 6 7 8 .342 .306 .278 .266 .234 .209 .212 .184 .160 .324 .292 .265 .254 .223 .201 .202 .176 .155 .292 .263 .240 .232 .203 .184 .187 .162 .143 .262 .236 .218 .211 .186 .167 .172 .148 .132 .234 .213 .195 .190 .169 .152 .156 .135 .121 .135 .116 .103 Copyright© 2006 Cooper Crouse-Hinds 4 5 .410 .326 .262 .387 .311 .251 .344 .279 .229 .304 .250 .207 .267 .222 .184 .159 .382 .305 .246 .363 .291 .236 .327 .265 .218 .292 .240 .200 .260 .217 .181 .159 9 .265 .198 .153 .253 .191 .149 .231 .177 .139 .210 .162 .129 .191 .149 .118 .103 10 .233 .168 .127 .222 .163 .123 .203 .150 .114 .185 .138 .105 .167 .125 .096 .081 799 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: JOB: CRMAIN06-0800-2 Name: 4L-800 4L 100: DATE: JAN 19 2006 Time: 5:52:44 PM Operator: RB EVM Hazard ȿ Gard® H.I.D. Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Lamp: 150W/E-231⁄2 high pressure sodium (HPS) Total bare lamp lumens: 16000 Total bare lamp lumens: 16000 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. Luminaire With Globe, Hi-Bay Reflector and Without Guard Luminaire With Globe, Dome Reflector and Without Guard Lamp: 150W/E-231⁄2 high pressure sodium (HPS) NOTE: Photometric data was developed using a 150 watt clear high pressure sodium lamp (16,000 lumens). For other clear lamps, use the following conversion factors (multipliers): 50W HPS – .25; 70W HPS – .40; 100W HPS – .59. Multipliers are for use with candela curve only. NOTE: Photometric data was developed using a 150 watt clear high pressure sodium lamp (16,000 lumens). For other clear lamps, use the following conversion factors (multipliers): 50W HPS – .25; 70W HPS – .40; 100W HPS – .59. Multipliers are for use with candela curve only. Luminaire spacing ratio is 1.00. Luminaire spacing ratio is 1.20. Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 % Reflectance Eff. Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 .668 .618 .573 .651 .592 .542 .636 .569 .517 .655 .608 .566 .639 .583 .536 .625 .564 .513 .629 .587 .550 .616 .568 .525 .606 .550 .505 .606 .569 .535 .597 .554 .514 .588 .539 .497 .586 .553 .522 .578 .539 .504 .570 .528 .489 .560 .517 .479 Room Cavity Ratio 6 7 8 .460 .427 .396 .420 .388 .358 .394 .361 .330 .455 .423 .392 .418 .385 .356 .391 .359 .329 .444 .414 .385 .412 .380 .352 .388 .357 .328 .436 .406 .379 .407 .377 .348 .385 .354 .326 .428 .400 .373 .402 .373 .345 .382 .352 .324 .373 .343 .315 800 STIBOINFO((CRH:66008com:4L:800)) CH0 5 L - 2 1 98: 4 5 .531 .495 .468 .525 .491 .464 .511 .482 .459 .498 .474 .454 .487 .466 .449 .439 .494 .455 .427 .487 .452 .425 .476 .446 .422 .466 .438 .418 .457 .433 .413 .404 9 .369 .330 .303 .366 .328 .303 .360 .325 .301 .354 .322 .300 .348 .319 .298 .290 10 .328 .288 .262 .325 .288 .262 .320 .285 .261 .315 .282 .259 .311 .280 .258 .249 US: 1-866-764-5454 CAN: 1-800-265-0502 % Reflectance Eff. Ceil. Wall Room Cavity Ratio 1 2 3 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 % Reflectance Eff. Ceil. Wall 50 80 30 10 50 70 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 .716 .637 .568 .689 .596 .519 .666 .561 .480 .700 .624 .559 .675 .585 .512 .653 .555 .476 .668 .598 .538 .648 .567 .498 .631 .539 .466 .640 .575 .518 .625 .549 .485 .610 .526 .457 .615 .554 .500 .602 .532 .472 .590 .513 .448 .575 .498 .434 Room Cavity Ratio 6 7 8 .413 .373 .339 .355 .318 .285 .316 .280 .246 .405 .368 .334 .352 .314 .283 .312 .277 .245 .392 .356 .324 .345 .307 .277 .309 .274 .243 .380 .345 .316 .338 .303 .272 .306 .270 .241 .369 .337 .307 .331 .298 .267 .301 .267 .238 .289 .255 .226 Copyright© 2006 Cooper Crouse-Hinds 4 5 .507 .452 .410 .498 .447 .407 .479 .435 .400 .463 .425 .394 .447 .415 .388 .373 .455 .398 .355 .446 .393 .353 .432 .385 .349 .417 .376 .344 .404 .369 .339 .326 9 .312 .258 .221 .308 .256 .221 .299 .252 .219 .291 .247 .217 .283 .244 .215 .203 10 .275 .222 .187 .271 .222 .187 .264 .217 .185 .257 .214 .183 .251 .210 .181 .170 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0801-7 Name: 5L-801 100: DATE: JAN 19 2006 Time: 5:52:45 PM Operator: RB COLOR: CMYK TCP: 15001 Luminaires with Induction Lighting System Typedriver Name: TS name csm no.: 100 5L Hazardous and Non-Hazardous Description Page No. VMVIG Series DMVIG Series 802–808 802–808 Note: Induction Lighting is also available with our Champ-Pak TM Wall Pack Luminares. Please see page 867 in Section 7L for more details. US: 1-866-764-5454 STIBOINFO((CRH:66008com:5L:801)) CH0 0 5 L 2 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 801 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0802-17 Name: 5L-802 5L 100: DATE: JAN 19 2006 Time: 5:52:46 PM Operator: RB Luminaires with Induction Lighting System VMVIG and DMVIG Series COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Class I, Division 2, Groups A,B,C,D Class I, Zone 2, Group IIC Resricted Breathing Suffix S826 for CI.I, Div 2 & Zone 2 Enclosure Type 4X, IP66 ɀ Marine Locations Wet Locations ɀ UL and cUL Listed Get uninterrupted light for up to 11 years, without changing a lamp. Cooper Crouse-Hinds® Champ Luminaire with Induction Light Source delivers up to 100,000 hours of white light in a hazardous location, corrosion-resistant watertight package. That’s 5 to 8 times the typical life of conventional fluorescent or HID lamps. And, with no maintenance required for up to 11 years, you’ll reduce your maintenance and lamp replacement costs. Compelling reasons to choose the new Champ Induction luminaire as the light source for industrial and hazardous locations include: ɀ Crisp white light (80+ color rendering index) provides increased safety by clearly illuminating signs, instrument panels, equipment and more with vibrant natural colors. ɀ Up to 100,000 hours of lamp life minimizes routine maintenance costs. If you operate this luminaire for 24 hours, 7 days a week, you will not need to change the lamp for up to 11 years! ɀ Instant illumination — no waiting for lamp warm-up time. Increases productivity and safety. ɀ Delivers the best possible luminaire temperature rating — T6 (85°C) when used with the Champ restricted breathing option. Ideal for hazardous areas where a low ignition temperature is required. ɀ Starts in low temperatures — as low as -40°C. 165W Champ Induction provides as much light as a 175W Metal Halide but lasts 7 times longer! ADDITIONAL FEATURES & BENEFITS: The Champ Induction luminaire is suitable for Class I, Division 2 and Zone 2 areas with the assurance of Cooper Crouse-Hinds quality and reliability. They are ideal for use in hard-to-reach applications and where process requirements demand continuous luminaire operation. Features: ɀ High lumens per watts (72 lpw for the 165W Champ) will save energy ɀ Retains strong light output (retains more than 70% output) throughout the life of the lamp ɀ Will not add electrical noise to the circuits — Total Harmonic Distortion is less than 10% ɀ Excellent power factor of .96 increases useable watts to an excellent level and reduces energy consumption ɀ Internal electronics are enclosed to ensure that there is no interference with external instrumentation 802 STIBOINFO((CRH:66008com:5L:802)) CH0 5 L - 2 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0803-21 Name: 5L-803 100: DATE: JAN 19 2006 Luminaires with Induction Lighting System VMVIG and DMVIG Series Time: 5:52:48 PM Operator: RB TCP: 15001 Typedriver Name: TS name csm no.: 100 Class I, Division 2, Groups A,B,C,D Class I, Zone 2, Group IIC Resricted Breathing Suffix S826 for CI.I, Div 2 & Zone 2 Enclosure Type 4X, IP66 ɀ Marine Locations Wet Locations ɀ UL and cUL Listed 5L APPLICATIONS: STANDARD FINISHES: Champ Induction luminaires are ideal: ɀ Where an extra long life lamp source (up to 100,000 hrs) is required. ɀ In areas that require lamps to reach full illumination immediately. ɀ Where cool temperature ratings on the luminaire globe are needed to ensure safe operation in hazardous areas. ɀ In hard-to-reach applications where relamping is costly. ɀ Where luminaire maintenance is difficult due to continuous process operation requirements that restrict or prohibit shut down except in emergency situations. ɀ To provide a cost-effective lighting system (low installed/life cost) by minimizing or even eliminating routine luminaire maintenance. ɀ In cold environment applications. ɀ Copper-free aluminum — epoxy powder coat ɀ Krydon® material — high reflectance white ɀ Stainless steel — natural CERTIFICATIONS AND COMPLIANCES: NEC & CEC: ɀ Class I, Division 2 and Zone 2 ɀ Class I, Division 2 Groups A, B, C, D Class I, Zone 2 Group IIC ɀ Restricted Breathing Suffix S826 for Class I, Division 2 & Zone 2 ɀ Marine Locations, Wet Locations, Enclosure Type 3, 3R, 4, 4X; IP66 ɀ UL and cUL Listed UL Standards: 844, 60079-15, 1598, 1598A CSA Standards: C22.2 No.137, E79 Series Compliances and aprovals for the lamp system ɀ RFI < 30 MHz ɀ RFI > 30 MHz ɀ Harmonics ɀ Immunity ɀ Safety ɀ Performance ɀ Vibration & bump tests ɀ Quality standards ɀ Environmental standard EN 55015 EN 55022 EN 61000-3-2 EN 61547 EN 61347-2-3 & UL935 EN 60928 EN 60929 IEC 68-2-6-Fc IEC 68-2-29-Eb ISO 9001 ISO 14001 STANDARD MATERIALS: ɀ Ballast housings and mountings — copper-free aluminum (less than 0.4 of 1%) ɀ Exterior hardware — stainless steel ɀ Reflectors (dome and angle) — Krydon fiberglass-reinforced polyester material ɀ Globes — heat and impact-resistant internally fluted glass ɀ Guards — copper-free aluminum (55W), stainless steel (85W). US: 1-866-764-5454 STIBOINFO((CRH:66008com:5L:803)) CH0 0 5 L 2 0 COLOR: CMYK CAN: 1-800-265-0502 OPTIONS: DESCRIPTION Restricted Breathing Construction Class I, Division 2 & Zone 2 suitability Cooler operating temperatures (T-Codes) SUFFIX TO ADD TO CATALOG NO. S826 ACCESSORIES: MOUNTING MODULES 3⁄4 NPT Pendant 1 NPT Pendant 3⁄4 NPT Flexible Pendant 3⁄4 NPT Ceiling Mount 1 NPT Ceiling Mount 3⁄4 NPT Wall Mount 1 NPT Wall Mount 3⁄4 NPT Quad Mount 1 1⁄2 NPT Stanchion Mount — 25 Degree Angle 1 1⁄2 NPT Stanchion Mount — Straight WATTAGE 55W 85W 165W DOME REFLECTOR CATALOG NO. RD70 RD739 RD739 CAT. NO. APM2 APM3 HPM2 CM2 CM3 TWM2 TWM3 QM25 JM5 PM5 ANGLE REFLECTORS CATALOG NO. RA70 RA739 RA739 DIMENSIONS: See Catalog 6000 Section 3L for dimensional information on VMV and DMV Series AMPERAGE: Power consumption for specific voltages as follows: 55W LUMINAIRES a. 120VAC x .460mA ⍧ 55.70 watts b. 230VAC x .260mA ⍧ 59.80 watts 85W LUMINAIRES c. 120VAC x .710mA ⍧ 85.20 watts d. 230VAC x .400mA ⍧ 92.00 watts 165W LUMINAIRES e. 230VAC x .700mA ⍧ 161.00 watts Copyright© 2006 Cooper Crouse-Hinds 803 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0804-30 Name: 5L-804 5L DATE: JAN 19 2006 Time: 5:52:48 PM Operator: RB Luminaires with Induction Lighting System VMVIG and DMVIG Series COLOR: CMYK VMV DMV DMV LUMEN (LM) INITIAL MEAN 3500 2800 6000 4800 12000 9600 Typedriver Name: TS name csm no.: 100 Class I, Division 2, Groups A,B,C,D Class I, Zone 2, Group IIC Restricted Breathing Suffix S826 for CI.I, Div 2 & Zone 2 Enclosure Type 4X, IP66 ɀ Marine Locations Wet Locations ɀ UL and cUL Listed LAMP DATA: SYSTEM Power (W) 55 85 165 TCP: 15001 COLOR RENDERING INDEX* 80 80 80 EFFICACY (LM/W) INITIAL MEAN 65 51 70 57 72 58 LUMEN MAINTENANCE AFTER 60,000 HRS (%) 75 75 70 * Lamp sources with 80+ CRI provide excellent color rendering. CRI scale is 0-100 with 100 considered as ideal. TEMPERATURE PERFORMANCE DATA: CATALOG # VMVIG055 VMVIG055 DMVIG085 DMVIG085 DMVIG165 WATTS 55 55 85 85 165 AMBIENT TEMP °C 40 55 40 55 40 SUPPLY WIRE TEMP °C 60 75 60 75 75 CLASS I, DIV. 2 TEMP. RATING T2C T2C T2D T2D T3 CLASS II, DIV. 1, CLASS III TEMP. RATING – – T2D – – SIMULTANEOUS PRESENCE CLASS I, DIV. 2 – – T2D – – RESTRICTED BREATHING (SUFFIX S826) Aex nR IIC, Ex nR IIC CLASS I, DIV. 2/Zone 2 T6 T5 T6 T6 T5 Champ Induction DMV 85-watt is now Class II Div.1 – suitable for dust environments ORDERING INFORMATION: To complete Catalog Number, add Voltage and Option suffix(es). MOUNTING STYLE Pendant Flexible Pendant Ceiling Mount Wall Mount Quad Mount Stanchion Mount 25° Angle Stanchion Mount Straight Luminaire with Globe and Guard less Mounting Module Standard Voltage 120V, 50/60 Hz 200V-277V, 50/60 Hz HUB SIZE (INCHES) 3⁄4 1 3⁄4 3⁄4 1 3⁄4 1 3⁄4 1 1⁄2 1 1⁄2 55W INDUCTION CATALOG NUMBER (WITH G24 GLOBE & P21 GUARD) VMVIG2A055GP VMVIG3A055GP VMVIG2HA055GP VMVIG2C055GP VMVIG3C055GP VMVIG2TW055GP VMVIG3TW055GP VMVIG25Q055GP VMVIGJ055GP VMVIG2P055GP 85W INDUCTION CATALOG NUMBER (WITH G303 GLOBE & P33 GUARD) DMVIG2A085GP DMVIG3A085GP DMVIG2HA085GP DMVIG2C085GP DMVIG3C085GP DMVIG2TW085GP DMVIG3TW085GP DMVIG25Q085GP DMVIGJ085GP DMVIG2P085GP 165W INDUCTION CATALOG NUMBER (WITH G303 GLOBE & P33 GUARD) *DMVIG2A165GP *DMVIG3A165GP *DMVIG2HA165GP *DMVIG2C165GP *DMVIG3C165GP *DMVIG2TW165GP *DMVIG3TW165GP *DMVIG25Q165GP *DMVIGJ165GP *DMVIG2P165GP — VMVIG055GP DMVIG085GP *DMVIG165GP Suffix /120 /200 277 Operative range of 108-132 VAC Operates on 208, 220, 230, 240, 277 VAC Add the voltage suffix to the above catalog number. Ex. - DMVIG2A085GP/120 * 165W Champ Induction Luminaires are only available in 200-277VAC 804 STIBOINFO((CRH:66008com:5L:804)) CH0 5 L - 2 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0805-17 Name: 5L-805 100: DATE: JAN 19 2006 Time: 5:52:49 PM Operator: JB COLOR: CMYK TCP: 15001 Photometric Data Luminaires with Induction Lighting System Typedriver Name: TS name csm no.: 100 5L VMVIG and DMVIG Series 55 WATT INDUCTION LUMINAIRE WITH GLOBE AND GUARD VMVIG055GP LAMP: 55W INDUCTION 85 WATT INDUCTION LUMINAIRE WITH GLOBE AND GUARD DMVIG085GP LAMP: 85W INDUCTION Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our Luxicon Lighting Layout Software are available to download US: 1-866-764-5454 STIBOINFO((CRH:66008com:5L:805)) CH0 0 5 L 2 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 805 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0806-9 Name: 5L-806 5L 100: DATE: JAN 19 2006 Time: 5:52:52 PM Operator: JB Luminaires with Induction Lighting System COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data VMVIG and DMVIG Series 165 WATT INDUCTION LUMINAIRE WITH GLOBE DMVIG165G LAMP: 165W INDUCTION 165 WATT INDUCTION LUMINAIRE WITH GLOBE AND GUARD DMVIG165GP LAMP: 165W INDUCTION Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our Luxicon Lighting Layout Software are available to download 806 STIBOINFO((CRH:66008com:5L:806)) CH0 5 L - 2 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0807-9 Name: 5L-807 100: DATE: JAN 19 2006 Time: 5:52:54 PM Operator: JB COLOR: CMYK TCP: 15001 Photometric Data Luminaires with Induction Lighting System Typedriver Name: TS name csm no.: 100 5L VMVIG and DMVIG Series 165 WATT INDUCTION LUMINAIRE WITH GLOBE AND RD739 DOME REFLECTOR DMVIG165G LAMP: 165W INDUCTION 165 WATT INDUCTION LUMINAIRE WITH GLOBE AND RA739 (30° ANGLE) REFLECTOR DMVIG165G LAMP: 165W INDUCTION Photometric Data: For additional photometric information, see the Resources area of our website. Photometric .ies files for use with our Luxicon Lighting Layout Software are available to download US: 1-866-764-5454 STIBOINFO((CRH:66008com:5L:807)) CH0 0 5 L 2 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 807 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0808-7 Name: 5L-808 5L 100: DATE: JAN 19 2006 Time: 5:52:56 PM Operator: JB Luminaires with Induction Lighting System COLOR: CMYK TCP: 15001 Family Tree VMVIG and DMVIG Series 808 STIBOINFO((CRH:66008com:5L:808)) CH0 5 L - 2 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0809-5 Name: 6L-809 100: DATE: JAN 19 2006 Time: 5:52:57 PM Operator: JB COLOR: CMYK TCP: 15001 Fluorescent Luminaires Hazardous and Non-Hazardous Typedriver Name: TS name csm no.: 100 6L Description Page No. Application/Selection 810 General Purpose Luminaires VF Vaporgard TM Series 811-813 Non-Metallic Luminaires NFL Series N2MVF 843-845 823-828 Hazardous Area Luminaires CPMVF DMVF eLLB20 Series eLLK Series EVLPF EVF Series EVFDR Series EVFT Illuminator TM Series FVN Series FVS Series nLLK Series US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:809)) CH0 0 0 0 5 L CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 814, 815 816-822 855-857 846-848 829-835 858-861 862, 863 839-842 852-854 836-838 849-851 809 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0810-9 Name: 6L-810 100: DATE: JAN 19 2006 Time: 5:52:57 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Fluorescent Lighting Luminaires 6L Hazardous and Non-Hazardous Application and Selection Quick Selector Chart Application: ɀ for use in hazardous or non-hazardous areas (as shown in the Quick Selector Chart below) ɀ low operating cost ɀ high light output per watt ɀ low brightness ɀ low glare ɀ uniform light ɀ instant illumination Considerations for Selection: Table 500-3(d) Identification Numbers. Having made the determination that a fluorescent luminaire is required, the remaining selection is the type of luminaire (i.e., number and kind of lamps) and placement of luminaire. To determine the number of luminaires: 1. Determine Cavity Ratios for room, ceiling and floor. 2. Determine Coefficient of Utilization 3. Determine Light Loss 4. Determine Lamp Lumens required = Footcandles x Area Coefficient of Utilization x Light Loss Factor 5. Determine number of luminaires required = Total Lamp Lumens Required Lamp Lumens per Luminaire A more complete explanation of the steps to be followed can be found in the Lighting Selector Guide, pages 665 through 689. Maximum Temperature Deg. C Deg. F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185 Quick Selector Chart Series NEC – Hazardous Area Compliance Lamp Watts Volts No. of Lamps VF Cl. I, Division 2, Groups A,B,C,D NFL Cl. I, Division 2, Groups A,B,C,D 5, 7, 9 120 2 32, 40 120-277V 50-60Hz 1, 2 FVN Cl. I, Division 2, Groups A,B,C,D; Cl. II, Groups F,G; Cl. III 32, 40, 60 120, 277, 220/240 50 or 60 Hz 2, 3 EVF Cl. I, Groups C,D; Cl. II, Groups E,F,G 32, 40, 60, 110 120, 277, 347, 220/240 50 or 60 Hz 1, 2, 3, 4 EVFDR Cl. I, Groups C,D; Cl. II, Groups E,F,G 32, 40, 60, 110 120, 277, 220/240 50 or 60 Hz 2 EVFT Cl. I, Groups B,C,D; Cl. II, Groups E,F,G; Cl. III 39 120, 277, 220/240 50 or 60 Hz 2, 4 FVS Cl. I, Division 2, Groups B,C,D; Cl. II, Groups E,F,G; Cl. III 40 120-277V, 50-60Hz or 347V, 60Hz 2 DMVF Cl. I, Division 2, Groups A,B,C,D; Cl. II, Groups E,F,G; Cl. III; Simultaneous Presence 26, 32 120-277V, 50-60Hz or 347V, 60Hz 2, 3 N2MVF Cl. I, Div. 2, Groups A,B,C,D Class II, Groups F,G Class III; Simultaneous Presence 26, 32 120-277V, 50-60Hz or 347V, 60Hz 2 EVLP Cl. I, Div.1, Groups (B), C, D Cl. II, Groups E, F, G Cl. III; Simultaneous Presence 26, 32 120-277V, 50-60Hz or 347V, 60Hz 2 CPMVF Cl. I, Div. 2, Groups A, B, C, D 26, 32, 42 120-277V, 50-60Hz, 347V 60Hz 2 eLLB 20 Cl. I, Division 2, Groups A,B,C,D; Cl. I, Zone 1, Group IIC; Cl. II, Division 2, Groups F,G 17, 32 120-240V, 50-60Hz 110-230 VDC 2 ELLK Cl. I, Zone I & Div 2 Cl. II, Div 2 32 120-254V 2 nLLK Cl. I, Division 2, Groups A,B,C,D; Cl. I, Zone 2 AEx nA II; Cl. II, Division 2, Groups F,G 17, 32 120-277V, 60Hz 2 810 STIBOINFO((CRH:66008com:6L:810)) CH0 0 5 L - 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Identification Number T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0811-4 Name: 6L-811 100: DATE: JAN 19 2006 Time: 5:52:58 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. I, Div. 2, Groups A,B,C,D* Cl. I, Zone 2 IIC* ɀ Wet Locations ɀ NEMA 3,3R VF Series Vaporgard TM Fluorescent Luminaires 6L ɀ Application: Accessories: VF series Vaporgard fluorescent lighting luminaires are used: ɀ indoors or outdoors in industrial locations where enclosed and gasketed luminaires are required ɀ where the energy efficiency and long life of single twin-tube compact fluorescent lamps are desired ɀ where luminaires may be subject to wet, damp, dirty locations ɀ where vibration and rough usage are a problem ɀ to retrofit existing Vaporgard incandescent luminaires ɀ in tunnels, building entrances, utility rooms, hallways and similar locations ɀ with clear or colored globes to illuminate or mark critical locations or processes ɀ See page 812 for complete listing Luminaire Net Weights: 1-Lamp 2-Lamp Luminaire Luminaire Fixture With Globe & With Globe & Type Guard (lbs.) Guard (lbs.) 5 VFA 43⁄4 VFHF 5 51⁄4 VFHBF 71⁄4 71⁄2 Add for Reflectors (lbs.): Dome 1 30° Angle 1 1⁄2 Deduct (lbs.): P21 Guard Temperature Performance Data: Features: ɀ Compact size and light weight allow adaptation and easy installation in many industrial applications ɀ Cast copper-free aluminum (less than 0.4 of 1% copper) construction and epoxy powder finish provide excellent resistance to corrosion ɀ Variety of mounting arrangements to suit any lighting layout – pendant, ceiling, wall bracket, angle stanchion, through feed, box mount ɀ VFH luminaire components can be installed on existing Vaporgard incandescent components and standard stamped metal boxes ɀ Fixtures available for use with two compact fluorescent lamps. Lamps rated at 5, 7 or 9 watts can be used with all luminaires ɀ Dome and 30° angle reflectors made of bright white Krydon® material provide superior reflectivity. Will not chip, peel, dent, rust or corrode. (Order separately – see page 812) ɀ Glass globes are internally fluted and stippled to reduce glare and provide even light distribution. Exteriors are smooth to shed dust ɀ All luminaires 120 VAC only! ɀ Grounding wire for safety Certifications and Compliances: Class I Lamp Div. 2 5, 7W T3B 9W T3B Max. Ambient 40°C 40°C Supply Wire °C 75°C 75°C Minimum Operating –18°C (0°F) –4°C (25°F) ɀ UL Standard: 1598, 844 ɀ CSA Standard C22.2 No. 137 Dimensions VFHA VFC VFH Standard Materials: ɀ Bodies and guards – copper-free aluminum (less than 0.4 of 1%) ɀ Globes – clear or colored, glass or plastic ɀ Reflectors – Krydon fiberglass-reinforced polyester material VFHF VFHBF VFHT VFA Standard Finishes: ɀ Copper-free aluminum – powder epoxy finish ɀ Krydon material – high reflectance white Electrical Ratings: ɀ Input voltage – 120 VAC, 60 hertz ɀ Wattages: two 5, 7 or 9 watt lamps * All mountings except stanchion. US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:811)) CH0 0 5 L - 1 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 811 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0812-3 Name: 6L-812 100: DATE: JAN 19 2006 Time: 5:52:59 PM Operator: TB VF Series Vaporgard TM Fluorescent Luminaires 6L COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. I, Div. 2, Groups A,B,C,D** Cl. I, Zone 2 IIC** ɀ Wet Locations ɀ NEMA 3,3R ɀ Twin-Tube Fluorescent with G24 Clear Glass Globe and P21 Guard (lamps not included) Luminaire Watts Hub Size 1⁄2 2 Lamps, 18 3⁄4 1 watts max. 11⁄4 Pendant Mount Cat. # VFA122GP VFA222GP VFA322GP Ceiling Mount Cat. # VFHF122GP VFHF222GP Wall Mount (w/Box) Cat. # VFHBF122GP VFHBF222GP Wall Mount (No Box) Cat. # VFHT122GP VFHT222GP Angle Stanchion Mount* Cat. # Through Feed Mount Cat. # VFC122GP VFC222GP Box Mount & Retrofit Cat. # VFH122GP VFHA422GP* VF Series with Colored Glass Globes or Plastic Globes. To obtain: ɀ Substitute appropriate globe designation for ‘‘G’’ in above Cat. Nos. ɀ Refer to section 1L for globe designations. Accessories and Components Reflectors Globes Guard For use with glass globes only Dome Cat. # RD71 (Cannot be used with wall mount luminaires) 30°Angle Cat. # RA71 Color Clear Green Blue Red Amber Glass Cat. # G24 G25 G26 G27 G28 Plastic Cat. * G63 G65 G67 Cat. # P21 Junction Boxes and Bracket Bodies VXF – 4 Hubs, 3 Plugs Hub Size 1⁄2 3⁄4 Cat. # VXF10 VXF20 VXFT– 5 Hubs, 4 Plugs Hub Size 1⁄2 3⁄4 Cat. # VXFT10 VXFT20 * For non-hazardous locations. – available with Lightning Service TMdelivery See Section G for complete details 812 STIBOINFO((CRH:66008com:6L:812)) CH0 0 5 L - 2 VXT – 3 Hubs, 2 Plugs Hub Size 1⁄2 3⁄4 Cat. # VXT10 VXT20 VXA – Stanchion Mount (Non Hazardous Locations) Hub Size 11⁄4 Cat. # VXA4 VXB – 3 Hubs, 2 Plugs Hub Size 1⁄2 3⁄4 Cat. # VXB10 (Includes adapter plate and two gaskets for mounting to VXF, GRF or 4⍯ outlet boxes) VXB11 (Includes 1 gasket for mounting to VXF or GRF junction boxes.) ** All mountings except stanchion. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0813-2 Name: 6L-813 100: DATE: JAN 19 2006 Time: 5:53:02 PM Operator: TB COLOR: CMYK TCP: 15001 Family Tree Vaporgard TM Series Fluorescent Luminaires Typedriver Name: TS name csm no.: 100 6L – available with Lightning Service TM delivery. See Section G for complete details. US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:813)) CH0 0 5 L - 1 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 813 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0814-5 Name: 6L-814 6L 100: DATE: JAN 19 2006 Time: 5:53:03 PM Operator: TB CPMVF Champ-Pak TM Compact Fluorescent Luminaires COLOR: CMYK ɀ Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2* (Suffix S826) ɀ Certified for IEC Zone 2* (Suffix S826TB) ɀ TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence* ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP56 Application: CPMVF Champ-Pak TM luminaires are used: ɀ Indoor and outdoor wall mounting or vertical surface mounting where minimal luminaire depth is required in: – Manufacturing plants and heavy industrial facilities – Industrial process facilities such as refineries, chemical, petrochemical, pharmaceutical and platforms – Waste or sewage treatments plants – Offshore, dockside and harbor installations ɀ For security and safety lighting in industrial facilities for lighting of loading docks, tunnels and stairways ɀ For marine, wet location, hosedown and corrosive environments Features & Benefits: ɀ Unique compact shallow-profile design mounts virtually anywhere ɀ Side hinged cover with two screw closing for easy installation and maintenance ɀ Gray Corro-free TM epoxy powder coat two-piece housing provides superior corrosion resistance ɀ Unique stainless steel wire guard accessory attaches without any additional hardware for easy installation and maintenance ɀ Glass refractor provides uniform light distribution to eliminate glare ɀ Silicon gaskets make luminaire suitable for NEMA 4X, Marine environments ɀ High power factor ballasts (+90%) are standard, which allow more luminaires per circuit Standard Materials: ɀ Luminaire housing and door frame assembly – copper-free aluminum ɀ External hardware – stainless steel ɀ Lens – heat and impact-resistant refractor style glass ɀ Gaskets – silicon rubber ɀ Reflector – aluminum light sheet ɀ Wire guard – stainless steel Standard Finishes: ɀ Aluminum – Corro-free TM epoxy powder coat ɀ Stainless steel – natural Certificates and Compliances: ɀ NEC and CEC: - Class I, Division 2, Groups A, B, C, D - Class II, Class III & Simultaneous Presence (Class 1, Division 2 and Class II)* - Class I Zone 2 ɀ IEC: - Zone 2 Ex nR IIC ɀ UL Standards: - 844, 2279 Hazardous (Classified) Locations - 1598 Luminaires - 1598A Marine Locations ɀ CSA Standards - C22.2 No. 137 ɀ IEC Standards - 60079-15 Electrical Rating Ranges: ɀ Wattages: Two 26, 32, or 42 watt lamps. ɀ 120-277V, 50-60Hz ɀ 347V, 60Hz ɀ 12, 24 & 125VDC (Consult Cooper Crouse-Hinds) Options: Suffix to add to Cat. No. # ɀ Restricted Breathing Construction - Class I Division 2 & Zone 2 Suitability . . . . . . . . . . . . . . . . . . . S826* - Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 (Suffix S826TB). . . . . . . . . . . . . . . . . S826TB* (Guard Required) - Furnished with - Terminal Block - Crimp Terminals ɀ Factory Assembled with Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FA ɀ Fused - protects ballast and capacitors. . . . . . . . . . . . . . . . . . . . S658† against abnormal line conditions (Not for use in Canada) (Not for Marine use) Accessories: Photocell for Field Installation ɀ 120V, 50/60Hz ɀ 208-240V, 50/60Hz ɀ 277V, 50/60Hz Stainless Steel Wire Guard ɀ Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output. * Contact Cooper Crouse-Hinds STIBOINFO((CRH:66008com:6L:814)) CH0 5 L - 1 4 US: 1-866-764-5454 V2PC20 V2PC22 V2PC27 P55 † When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT in the catalog number. Energy Savings: 814 Cat. # CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0815-3 Name: 6L-815 DATE: JAN 19 2006 Time: 5:53:04 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Ordering Information Temperature Performance Data Dimensions & Weights CPMVF Champ-Pak TM Compact Fluorescent Luminaires 6L Ordering Information: Hub Size 3⁄4 NPT 3⁄4 NPT 3⁄4 NPT Luminaire Watts 52 64 84 Catalog Number CPMVF2W052 CPMVF2W064 CPMVF2W084 STANDARD VOLTAGE BALLASTS OPTIONAL BALLASTS NEC/UL & CEC/CSA (cUL) CEC/CSA (cUL) 120-277V 50-60Hz /UNV 347V 60Hz /347 Voltage Suffix (Consult Cooper Crouse-Hinds) 125V DC /125VDC 12V DC /012VDC 24V DC /024VDC CPMVF Temperature Performance Data – Consult Cooper Crouse-Hinds Dimensions (Inches) Net Weight: CPMVF Less Guard P55 Guard 17 Lbs 0.5 Lbs US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:815)) CH0 0 3 L - 4 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 815 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0816-5 Name: 6L-816 6L 100: DATE: JAN 19 2006 Time: 5:53:05 PM Operator: JB DMVF Series Compact Fluorescent Champ® Luminaires COLOR: CMYK ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Application: Energy Savings DMVF series Champ luminaires are used: ɀ in areas made hazardous by abnormal conditions resulting in the presence of flammable vapors or gases. ɀ in areas made hazardous by the presence of combustible dusts. ɀ where combustible dusts and flammable vapors are present simultaneously. ɀ in marine applications where water spray and corrosive atmospheres are considerations. ɀ on installations where vibration and rough usage are problems. ɀ where a cool, efficient light source is required. ɀ in areas that require lamps to reach full illumination immediately. ɀ in refineries, chemical and petrochemical facilities, grain processing, handling or storage facilities, manufacturing plants waste water treatment plants sewage treatment plants, oil terminals, food processing facilities, breweries, and any other manufacturing or processing facility where safe, reliable, hazardous area fluorescent or auxiliary lighting is needed. ɀ Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output. Standard Features: ɀ Housings made of die-cast copper-free aluminum (less than 0.4 of 1% copper) for strength and resistance to corrosion. ɀ Mounting modules equipped with integral hub set screws for vibration resistance (ceiling, pendant, and quad mounts). ɀ Hubs are provided with an integral conduit stop and bushing to help prevent damage to field wiring during installation. ɀ Epoxy powder finish and stainless steel external hardware for resistance to corrosion. ɀ Long-life gaskets which provide seals between mounting module, housing, and optical assembly. ɀ Grounding wire for safety. ɀ Cool operating design. ɀ Optional stainless steel open bottom guard permits direct access to the globe for easy relamping. ɀ Optional battery pack ballast for auxiliary lighting. TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 Standard Materials: ɀ Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%). ɀ Exterior hardware and guards – stainless steel. ɀ Reflectors – Krydon® fiberglass-reinforced polyester material. ɀ Globe – heat and impact resistant internally fluted glass. Standard Finishes: ɀ Aluminum – gray epoxy powder coat. ɀ Krydon material – high reflectance white. ɀ Stainless steel – natural. Electrical Rating Ranges: ɀ Wattage: Two 26 or 32 watt lamps ɀ 120-277V, 50-60 Hz ɀ 347V, 60Hz ɀ 12, 24, & 125VDC Certificates and Compliances: ɀ NEC and CEC: Class I, Division 2, Groups A, B, C, D Class II, Class III & Simultaneous Presence (Class 1, Division 2 and Class II) Class I Zone 2 ɀ IEC: Zone 2 Ex nR IIC ɀ UL Standards: 844, 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards C22.2 No. 137 ɀ IEC Standards 60079-15 Accessories: (Order separately) ɀ Reflectors (to be used with globe) Dome Cat. # RD739 30° Angle Cat. # RA739 Options: Description Suffix to add to Cat. No. # ɀ Restricted Breathing Construction Class I Division 2 & Zone 2 Suitability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S826 Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 (Suffix S826TB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S826TB Furnished with Terminal Block Crimp Terminals ɀ Factory Assembled with lamps installed for additional labor savings. . . . . . . . . . . . . . . . . . . . FA. ɀ Fused – to protect ballast against abnormal line conditions (not available on CSA certified fixtures) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S658*. ɀ Lamps supplied with fixture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S714. ɀ Top hat with stainless steel threaded insert to attach ballast housing . . . . . . . . . . . . . . . . . S806. ɀ TEFLON® coating on globe for increased shatter protection . . . . . . . . . . . . . . . . . . . . . . . . . S808. * When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT in the catalog number. 816 STIBOINFO((CRH:66008com:6L:816)) CH0 0 5 L - 8 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0817-4 Name: 6L-817 DATE: JAN 19 2006 DMVF Series Compact Fluorescent Champ® Luminaires Time: 5:54:07 PM Operator: GK COLOR: CMYK ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Mounting Style Pendant Mount Hub Size 3⁄4 1 3⁄4 1 Luminaire Watts 52 64 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 6L DMVF Series Fluorescent Cat. No. with G303 Globe and P33 Guard DMVF2A052GP DMVF3A052GP DMVF2A064GP DMVF3A064GP Flexible Pendant Mount 3⁄4 3⁄4 52 64 DMVF2HA052GP DMVF2HA064GP Ceiling Mount Thru-Feed 3⁄4 52 1 3⁄4 1 64 DMVF2C052GP DMVF3C052GP DMVF2C064GP DMVF3C064GP 3⁄4 52 1 3⁄4 1 64 Wall Mount Thru-Feed TCP: 15001 DMVF2TW052GP DMVF3TW052GP DMVF2TW064GP DMVF3TW064GP Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 121⁄2° Angle 3⁄4 3⁄4 52 64 DMVF25Q052GP DMVF25Q064GP Stanchion Mount 25° Angle 11⁄2 11⁄2 52 64 DMVFJ052GP DMVFJ064GP Stanchion Mount Straight 11⁄2 11⁄2 52 64 DMVFP052GP DMVFP064GP 1. Catalog numbers are basic numbers. Voltages must be specified. Voltage Suffix STANDARD VOLTAGE BALLASTS NEC/UL & CEC/CSA (cUL) 120-277V 50-60Hz /UNV US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:817)) CH0 0 5 L - 9 CAN: 1-800-265-0502 OPTIONAL BALLASTS CEC/CSA (cUL) 347V 60Hz /347 125V DC /125VDC Copyright© 2006 Cooper Crouse-Hinds 12V DC /012VDC 24V DC /024VDC 817 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0818-2 Name: 6L-818 6L 100: DATE: JAN 19 2006 Time: 5:54:12 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 DMVF Series Ordering by Components DMVF luminaires are available in components A complete luminaire consists of: I. Champ Cover (Mounting Module) II. DMVF Ballast Housing III. Globe, Globe Guard, Globe Reflectors I. Champ Cover (Mounting Module): Type Pendant Flexible Pendant Ceiling Wall Stanchion - 25 Degree Angle Stanchion - Straight Quad-Mount Conduit 3⁄4 1 3⁄4 3⁄4 1 3⁄4 1 11⁄2 11⁄2 3⁄4 Cat. No. APM2 APM3 HPM2 CM2 CM3 TWM2 TWM3 JM5 PM5 QM25 II. Ballast Housings. Complete catalog number must have the voltage suffix (UNV shown) and any options suffixes. Lamp Type Compact Fluorescent Lamp Watts 2 (26W) 2 (32W) Catalog Number DMVF052/UNV DMVF064/UNV III. Globe, Guards and Reflectors Type Globe Teflon Coated Globe Guard Globe Reflector-Dome Globe Reflector-Angle 818 STIBOINFO((CRH:66008com:6L:818)) CH0 3 L - 1 5 Catalog Number G303 G303-S808 P33 RD739 RA739 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0819-2 Name: 6L-819 100: DATE: JAN 19 2006 Time: 5:54:13 PM Operator: TB COLOR: CMYK TCP: 15001 Family Tree DMVF Series Compact Fluorescent Typedriver Name: TS name csm no.: 100 6L Champ® Luminaires * These plastic reflectors are for non-hazardous areas only (50-100W max.) – available with Lightning Service TM delivery. See Section G for complete details. US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:819)) CH0 3 L - 1 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 819 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0820-2 Name: 6L-820 6L DATE: JAN 19 2006 Time: 5:54:14 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Temperature Performance Data Weights DMVF Series Compact Fluorescent Champ® Luminaires Temperature Performance Data: Lamp Watts Fluorescent: Minimum Operating Temperature DMVF 52 & 64 Watt -20°C (4°F) Class I Non-Restricted Restricted Breathing Breathing Div. 2 Zone 2 or Div. 2 40°C (104°F) T3 T6 Maximum Ambient Temp Class II Division 1 T6 Simultaneous Presence Non-Restricted Restricted Breathing Breathing Cl.I, Div. 2/Cl.II Cl.I, Zone 2 or Div. 2/Cl.II T3/T6 T6 Net Luminaire Weights (lbs.) Luminaire Luminaire Lamp with Globe, Series Watts Guard (lbs.) DMVF 52, 64 181⁄4 Add for mounting modules (lbs.): Pendant 11⁄4 Flexible Pendant 11⁄2 Ceiling 23⁄4 Wall 41⁄2 Quad-Mount 31⁄2 Angle Stanchion 31⁄2 Straight Stanchion 41⁄2 Add for reflectors (lbs.): Dome 11⁄4 30° Angle 13⁄4 Deduct: 1 lb. for luminaire with P33 Guard 820 STIBOINFO((CRH:66008com:6L:820)) CH0 5 L - 1 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Supply Wire °C 60 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0821-2 Name: 6L-821 DATE: JAN 19 2006 Time: 5:54:15 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data DMVF Series Compact Fluorescent 6L Champ® Luminaires NOTE: For 52 watt DMVF applications, use a .75 multiplier. DMVF064GRD Dome Reflector Coefficients of Utilization Effective Floor Cavity Reflectance 20% DMVF Photometric Data ISOFOOTCANDLE CHART: Luminaire with globe and dome reflector DMVF064GRD Dome Reflector Room Cavity Ratio Eff. Ceil. 80* 70* 50* Wall 1 2 3 4 5 6 7 8 9 10 50* 30* 10* 50* 30* 10* .741 .694 .652 .722 .679 .640 .617 .548 .491 .601 .537 .483 .524 .445 .382 .510 .437 .378 .452 .370 .308 .440 .364 .305 .396 .314 .254 .386 .309 .252 .351 .271 .214 .342 .267 .212 .314 .237 .183 .307 .234 .182 .283 .210 .159 .277 .207 .158 .258 .188 .140 .252 .185 .139 .236 .169 .125 .231 .167 .124 50* 30* 10* .686 .650 .617 .570 .516 .470 .484 .421 .369 .418 .351 .299 .367 .299 .247 .326 .259 .209 .293 .227 .180 .265 .202 .155 .242 .181 .138 .223 .163 .123 .542 .497 .457 .516 .478 .444 .424 .460 .406 .361 .437 .392 .352 .332 .398 .340 .293 .379 .329 .287 .267 .350 .290 .243 .333 .271 .239 .220 .311 .251 .206 .297 .244 .203 .184 .280 .221 .177 .268 .215 .175 .157 .254 .197 .154 .244 .192 .152 .136 .233 .176 .136 .224 .172 .135 .119 .214 .160 .121 .206 .156 .120 .105 50* .653 30* .623 10* .596 .50* .622 10* 30* .598 10* .576 0* 0* .557 * Percent Reflectance 30* Footcandle Values for Isofootcandle Lines MTG. HGT. 8′ 10′ 12′ 16′ A 4.00 2.56 1.78 1.00 B 2.00 1.28 0.89 0.50 C 1.00 0.64 0.44 0.25 D 0.50 0.32 0.22 0.13 E 0.25 0.16 0.11 0.06 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:821)) CH0 5 L - 1 2 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 821 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0822-2 Name: 6L-822 DATE: JAN 19 2006 Time: 5:54:16 PM Operator: TB TCP: 15001 Dimensions DMVF Series Compact Fluorescent 6L COLOR: CMYK Champ® Luminaires DMVF Dimensions Pendant Mount Quad-Mount 25° Angle Stanchion Mount Ceiling Mount Ceiling Mount – Top View Straight Stanchion Mount 822 STIBOINFO((CRH:66008com:6L:822)) CH0 5 L - 1 3 Luminaire with Globe, Guard, Reflectors US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0823-2 Name: 6L-823 100: DATE: JAN 19 2006 N2MVF Series Compact Fluorescent Champ® Non-metallic Luminaires Time: 5:54:19 PM Operator: TB ɀ Cl. I, Div. 2, Groups A,B,C,D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Additional Features: FLUORESCENT ENERGY SAVINGS ɀ Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output. 6L Certifications and Compliances: ɀ NEC and CEC: Class I, Division 2, Groups A,B,C,D Class II, Class III & Simultaneous Presence (Class I Division 2 and II) Class I Zone 2 ɀ IEC: Zone 2 Ex nR IIC ɀ UL Standards: 844. 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards: C22.2 No. 137 ɀ IEC Standards: 60079-15 Standard Materials: ɀ Housing, mounting modules – polyphenylene sulfide (PPS) ɀ Guard, hub inserts, stanchion elbow, hardware – stainless steel ɀ Globe – heat & impact resistant, internally fluted glass ɀ Gaskets – silicone rubber Electrical Ratings: ɀ Wattages: Two 26 or 32 watt lamps. ɀ 120 – 277V, 50-60 Hz ɀ 347V, 60 Hz ɀ 12, 24 & 125 VDC US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:823)) Typedriver Name: TS name csm no.: 100 Cl. II Groups F,G, Cl. III & Simultaneous Presence ɀ Marine & Wet Locations ɀ 3,3R, 4,4X; IP56 N2MVF series Champ luminaires are used: ɀ in areas in which ignitable concentrations of flammable gases or vapors will be present due to abnormal, unusual or accidental conditions. ɀ in installations where moisture, dirt, vibration, corrosion or rough usage are concerns. ɀ wherever the damaging effects of water, wind, snow, sleet, hot sun or any combination of these elements are found. ɀ ideal for marine use; resists the harmful effects of salt water. ɀ withstands the harshest of corrosive environments. ɀ to provide low wattage spot and floodlighting. ɀ for general area lighting. ɀ in manufacturing plants, refineries, chemical, petrochemical and other industrial process facilities, wastewater and sewage treatment facilities, offshore, dockside and harbor installations as well as other heavy industrial applications. ɀ Housings and mounting modules made of polyphenylene sulfide (PPS) for strength and maximum resistance to corrosion. ɀ Pendant mounting module equipped with integral hub set screws for vibration resistance. ɀ Hubs are provided with an integral bushing to help prevent damage to field wiring during installation and ground connection for positive bonding. ɀ Guard, hub inserts, stanchion elbow and hardware made of stainless steel for maximum resistance to corrosion. ɀ Grounding wire for safety. ɀ Stainless steel open bottom guard permits direct access to the globe for easy relamping. ɀ Hinged assembly allows the luminaire to hang free during installation to permit the use of both hands when wiring. ɀ One, external captive screw for ease of installation. ɀ Handle – hinge assembly doubles as a handle for ease of installation, especially when carrying up a ladder. TCP: 15001 ɀ Application: Features and Benefits: CH0 5 L - 1 4 COLOR: CMYK Options: Description Suffix to be added to Cat. No. ɀ Restricted Breathing Construction S826 Class I Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 S826TB Furnished with Terminal Block Crimp Terminals Wall-Mount Arm For converting a ceiling-mount luminaire to a wall mount N2MV-WM1 Factory Assembled For a factory assembled luminaire with lamps installed FA Fusing To protect ballast against abnormal line conditions S658 Furnished with Lamps S714 Teflon Coated Globe Provides additional protection against shattered glass fragments when subject to thermal shock, etc. S808 Average Luminaire Weight (lbs.) Body, mounting module, globe, guard and reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 lbs. CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 823 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0824-2 Name: 6L-824 100: DATE: JAN 19 2006 Time: 5:54:19 PM Operator: TB N2MVF Series Compact Fluorescent 6L Champ® Non-metallic Luminaires COLOR: CMYK ɀ Cl. I, Div. 2, Groups A,B,C,D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups F,G, Cl. III & Simultaneous Presence ɀ Marine & Wet Locations ɀ 3,3R, 4,4X; IP56 N2MVF ORDERING INFORMATION Mounting Style Pendant Mount Ceiling Mount ThruFeed Stanchion Mount 25° Angle Hub Size 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 11⁄2 11⁄2 Lamp Watts 52 64 52 64 52 64 With G303 Globe and P33 Guard Cat. No.† N2MVF2A052GP N2MVF3A052GP N2MVF2A064GP N2MVF3A064GP N2MVF2C052GP N2MVF3C052GP N2MVF2C064GP N2MVF3C064GP N2MVFJ052GP N2MVFJ064GP STANDARD VOLTAGE BALLASTS Voltage Suffix NEC/UL & CEC/CSA (cUL) 120-277V 50-60Hz /UNV OPTIONAL BALLASTS CEC/CSA (cUL) 347V 60Hz /347 125V DC /125VDC 12V DC /012VDC 24V DC /024VDC Temperature Performance Data: Lamp Watts Fluorescent: 52 & 64 Watt 824 STIBOINFO((CRH:66008com:6L:824)) CH0 5 L - 1 5 Class I Minimum Maximum Operating Ambient Non-Restricted Restricted Temperature Temp Breathing Breathing N2MVF Division 2 Zone 2 -18°C (0°F) 40°C (104°F) T2D T6 US: 1-866-764-5454 CAN: 1-800-265-0502 Class II Division 1 T4 F & G Simultaneous Presence Non-Restricted Restricted Breathing Breathing Cl.I, Div 2/Cl.II Cl.I, Zone 2/Cl.II T2B/T4 T4 Copyright© 2006 Cooper Crouse-Hinds Supply Wire °C 85 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0825-3 Name: 6L-825 100: DATE: JAN 19 2006 Time: 5:54:20 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 N2MVF SeriesOrdering by Components 6L N2MVF luminaires are available in components A complete luminaire consists of: I. N2MV Cover (Mounting Module) II. N2MV Ballast Housing III. Globe, Refractors, Guards, Reflectors I. N2MV Cover (Mounting Module): Type Pendant Ceiling Wall (Use wall bracket accessory with Ceiling Cover) Stanchion - 25 Degree Angle Conduit 3⁄4 1 3⁄4 1 3⁄4 1 11⁄2 Cat. No. N2APM2 N2APM3 N2CM2 N2CM3 N2MV-WM1 and N2CM2 N2MV-WM1 and N2CM3 N2JM5 II. Ballast Housings. Complete catalog number must have the voltage suffix (UNV shown) and any options suffixes. Lamp Type Compact Fluorescent Lamp Watts 2 (26W) 2 (32W) Catalog Number N2MVF052/UNV N2MVF064/UNV III. Globe, Guard and Reflectors Type Globe Globe Teflon Coated Globe Guard Reflector Dome Reflector Angle Catalog Number G303 G303-S808 P33 RD739 RA740 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:825)) CH0 3 L - 1 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 825 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0826-2 Name: 6L-826 6L 100: DATE: JAN 19 2006 Time: 5:54:21 PM Operator: TB N2MVF Series Compact Fluorescent COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Family Tree Champ® Non-metallic Luminaires A complete luminaire consists of a cover mount, a ballast housing and a globe, with or without guard, refractor or reflector. ALL COMPONENTS ARE SUITABLE FOR USE IN ORDINARY LOCATIONS, CLASS 1, DIV.2 AND WET LOCATIONS. 826 STIBOINFO((CRH:66008com:6L:826)) CH0 3 L - 3 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0827-3 Name: 6L-827 DATE: JAN 19 2006 Time: 5:54:22 PM Operator: TB N2MVF Series Compact Fluorescent COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 6L Dimensions Weights Champ® Non-Metallic Luminaires Pendant Mount Ceiling Mount – Top View Ceiling Mount 25° Angle Stanchion Mount Wall Arm Mount Net Luminaire Weights (lbs.) Luminaire Series Lamp Watts Luminaire with Mounting Module, Globe, Guard & Refractor (lbs.) N2MVF052 N2MVF064 52 64 30 30 Accessories (Order Separately) Reflectors (to be used with globe) Dome Cat. RD739 (RD79) 30° Angle Cat. RA739 (RA79) US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:827)) CH0 5 L - 1 8 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 827 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0828-3 Name: 6L-828 6L 100: DATE: JAN 19 2006 Time: 5:54:23 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 N2MVF Series Compact Fluorescent Champ® Non-Metallic Luminaires Photometric Data NOTE: For 52 watt N2MVF applications, use a .75 multiplier. N2MVF Photometric Data ISOFOOTCANDLE CHART: Luminaire with globe and dome reflector N2MVF064GRD Dome Reflector Footcandle Values for Isofootcandle Lines MTG. HGT. A B C D E 8′ 4.00 2.00 1.00 0.50 0.25 10′ 2.56 1.28 0.64 0.32 0.16 12′ 1.78 0.89 0.44 0.22 0.11 16′ 1.00 0.50 0.25 0.13 0.06 828 STIBOINFO((CRH:66008com:6L:828)) CH0 5 L - 1 6 US: 1-866-764-5454 N2MVF064GRD Dome Reflector Coefficients of Utilization Effective Floor Cavity Reflectance 20% Room Cavity Ratio Eff. Ceil. Wall 1 2 3 4 5 6 7 8 9 10 80* 50* 30* 10* .741 .694 .652 .617 .548 .491 .524 .445 .382 .452 .370 .308 .396 .314 .254 .351 .271 .214 .314 .237 .183 .283 .210 .159 .258 .188 .140 .236 .169 .125 70* 50* 30* 10* .722 .679 .640 .601 .537 .483 .510 .437 .378 .440 .364 .305 .386 .309 .252 .342 .267 .212 .307 .234 .182 .277 .207 .158 .252 .185 .139 .231 .167 .124 .570 .516 .470 .542 .497 .457 .516 .478 .444 .424 .484 .421 .369 .460 .406 .361 .437 .392 .352 .332 .418 .351 .299 .398 .340 .293 .379 .329 .287 .267 .367 .299 .247 .350 .290 .243 .333 .271 .239 .220 .326 .259 .209 .311 .251 .206 .297 .244 .203 .184 .293 .227 .180 .280 .221 .177 .268 .215 .175 .157 .265 .202 .155 .254 .197 .154 .244 .192 .152 .136 .242 .181 .138 .233 .176 .136 .224 .172 .135 .119 .223 .163 .123 .214 .160 .121 .206 .156 .120 .105 50* .686 30* .650 10* .617 50* .653 30* 30* .623 10* .596 50* .622 10* 30* .598 10* .576 0* 0* .557 * Percent Reflectance 50* CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0829-4 Name: 6L-829 100: DATE: JAN 19 2006 EVLPF Series Compact Fluorescent Low Profile Hazard ȿ Gard® Luminaires Time: 5:54:23 PM Operator: JB COLOR: CMYK ɀ Cl. I, Div. 1, Groups B (GB Suffix),C,D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA ɀ Cl. II, Div 1, Groups E, F, G; Class III, Simultaneous Presence ɀ TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Marine & Wet Locations ɀ 3,3R,4,4X; IP66 6L Application: Cooper Crouse-Hinds Low Profile Hazard ȿ Gard® luminaires are used in: ɀ areas where flammable or explosive vapors or gases are present ɀ hazardous areas, both indoors and outdoors, where long life and low maintenance costs are desired ɀ petroleum refineries, chemical, petrochemical and pharmaceutical plants, oil terminals, gas plants and other heavy process industry facilities ɀ waste treatment facilities ɀ drilling platforms and other coastal and offshore hazardous areas Features - Benefits: ɀ Small compact size ɀ Two start Acme threaded construction ɀ Light weight copper-free aluminum housing with powdered epoxy finish ɀ All exterior hardware is corrosion-resistant stainless steel ɀ Four mounting arrangements pendant, ceiling, wall bracket and stanchion ɀ Wide range of light sources and wattages ɀ Marine and Nema 4X construction ɀ Integral ballast ɀ High power factor (90%+) ballasts ɀ Uses same mounting modules as the standard Hazard ȿ Gard® ɀ Internally fluted glass globes ɀ Krydon® construction dome and angle reflectors – won’t rust, corrode, dent, chip or peel ɀ Now available in components – luminaire body, mounting module, guard, reflectors ɀ Three wire construction is standard on Fluorescent Emergency Lighting ɀ Perfect where low mounting restrictions are a concern ɀ Easier assembly, installation and maintenance ɀ Superior corrosion resistance ɀ Suit any lighting layout ɀ Meet specific lighting needs ɀ Outdoor, hose down, marine and corrosive environments suitable ɀ Lowest installed cost ɀ Allows more luminaires per circuit ɀ Easy retrofitting when the Lo-Pro TM is the preferred choice ɀ Reduces glare and distributes light evenly – ideal for adverse environments typical of industrial facilities ɀ Ideal for adverse environments typical of industrial facilities ɀ Easily stocked for quick ship requirements ɀ For energy conservation, luminaires can be switched off without affecting the emergency operation feature Standard Finishes: Copper-free aluminum – Corro-free powdered epoxy ɀ Krydon – white ɀ Stainless steel guard TM Ratings (Electrical/Size): Sources/wattage: ɀ 52W (2-26W lamps) & 64W (2-32W lamps) ɀ 120-277V, 50-60 Hz ɀ 347V, 60Hz ɀ 12, 24, 125 VDC Conduit entries: ɀ 3⁄4⍯, 1⍯ NPT – Pendant, Wall Bracket, Ceiling ɀ 11⁄4⍯ NPT – Stanchion Certification & Compliances: ɀ NEC and CEC: Class I, Division 1, Groups B (GB suffix), C, D Class I, Zone 1 Groups IIB + H2 (GB Suffix),IIB, IIA Class II, Class III & Simultaneous Presence (Class I and Class II) ɀ UL Standards 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards C22.2 No. 137 Options: Description Group B suitability Fused Factory assembled with lamps Suffix to be added to Cat. # GB S658* FA Accessories: Description Dome reflector Angle reflector Cat. # RD739 RA739 * When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT in the catalog number. Standard Materials: ɀ Mounting modules, cover, ballast housing, globe holder – copper free aluminum ɀ Globe – heat and impact resistant glass ɀ Exterior hardware – stainless steel ɀ Reflectors (dome & angle) – Krydon TM fiberglass-reinforced polyester US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:829)) CH0 0 6 L 1 7 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 829 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0830-2 Name: 6L-830 100: DATE: JAN 19 2006 Time: 5:54:25 PM Operator: TB EVLPF Series Compact Fluorescent 6L Low Profile Hazard ȿ Gard® Luminaires COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div. 1, Groups B (GB Suffix),C,D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA ɀ Cl. II, Div 1, Groups E, F, G; Class III, Simualtaneous Presence Typedriver Name: TS name csm no.: 100 Marine & Wet Locations 3,3R, 4,4X; IP66 Ordering Information Pendant Hub With Guard Watt Size Catalog # Wall Brckt† With Guard Catalog # Ceiling† With Guard Catalog # Stanchion With Guard Catalog # Fluorescent—High Power Factor Ballast (Min. P.F. 90%) EVLPFA02521 EVLPFBX02521 EVLPFCX02521 52W 3⁄4 1 EVLPFA03521 EVLPFBX03521 EVLPFCX03521 EVLPFJ04521 11⁄4 64W 3⁄4 EVLPFA02641 EVLPFBX02641 EVLPFCX02641 1 EVLPFA03641 EVLPFBX03641 EVLPFCX03641 EVLPFJ04641 11⁄4 Pendant Mount Luminaire Body Less Mounting Module & Guard Catalog # EVLPF0520 EVLPF0640 Complete Catalog Number as follows: 1. Voltages - Add Suffix as follows: Standard Voltage Ballasts - 60Hz Voltage Suffix NEC/UL & CEC/CSA (cUL) 120-277V 50-60Hz /UNV Optional Ballasts CEC/CSA (cUL) 347V 60 Hz /347 125V DC /125VDC †Wall Bracket Mount †Ceiling Mount Stanchion Mount †Ceiling and bracket mounts have 4 hubs: 3 are plugged. 830 STIBOINFO((CRH:66008com:6L:830)) CH0 5 L - 1 9 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 12V DC /012VDC 24V DC /024VDC Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0831-3 Name: 6L-831 100: DATE: JAN 19 2006 Time: 5:54:26 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 EVLPF Series Ordering By Components 6L EVLP Luminaires are available in components. A complete light fixture consists of: I. Mounting Module II. Fixture Body III. Guard, Dome Reflector, Angle Reflector or Exit Sign Mounting Modules Type Pendant Conduit 3⁄4 1 3⁄4 1 Use EV22 or EV33 box with EV87 11⁄4 Ceiling & Wall Box Wall Bracket Arm Stanchion Guards Fluorescent Reflectors Dome Angle Catalog Number EVMP2 EVMP3 EV22 EV33 EV87 EVMJ4 EV512 RD739 RA739 PENDANT EVMP2 EVMP3 CEILING EV22 EV33 STANCHION EVMJ4 CEILING EV22 EV33 WALL BRACKET EV87 & EV22 or EV33 FIXTURE BODY EVLPF0520/UNV EVLPF0521/UNV EVLPF0640/UNV EVLPF0641/UNV GUARDS EV511 EV512 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:831)) CH0 0 5 L - 4 DOME REFLECTOR RD739 CAN: 1-800-265-0502 ANGLE REFLECTOR RA739 Copyright© 2006 Cooper Crouse-Hinds 831 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0832-2 Name: 6L-832 6L DATE: JAN 19 2006 Time: 5:54:27 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Temperature Performance Data EVLPF Series Compact Fluorescent Low Profile Hazard ȿ Gard® Luminaires Fluorescent Fixtures Maximum Ambient Fluorescent 832 STIBOINFO((CRH:66008com:6L:832)) CH0 0 5 L - 4 52W & 64W Class I, Group B (w/GB suffix) Groups C, D Class I Zone I 40°C T6 US: 1-866-764-5454 Class II Groups E, F, G Class III Simultaneous Presence 40°C T6 CAN: 1-800-265-0502 Supply Wire °C 75°C Copyright© 2006 Cooper Crouse-Hinds Minimum Operating Temperature -18°C Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0833-2 Name: 6L-833 100: DATE: JAN 19 2006 Time: 5:54:28 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Dimensions and Weights EVLPF Series Compact Fluorescent 6L Low Profile Hazard ȿ Gard® Luminaires Fluorescent A 15.69 B 14.69 C 18.25 D 18.46 E 22.34 F 21.30 WEIGHTS (LBS.) Item Fluorescent Weights 31.5 (EVLPF) Add Mounting Modules Pendant Ceiling Bracket Stanchion Add For Reflectors & Exit Sign RA739 RD739 DMVF–EXD Deduct for Wire Guard 1 2 4.5 2.5 1 1 5 .5 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:833)) CH0 0 5 L - 4 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 833 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0834-2 Name: 6L-834 6L 100: DATE: JAN 19 2006 Time: 5:54:29 PM Operator: TB COLOR: CMYK TCP: 15001 Photometric Data EVLPF Series Compact Fluorescent Low Profile Hazard ȿ Gard® Luminaires Luminaire with Globe and Guard EVLPFA03641 (2) 32 W Compact Fluorescent CANDELAS Mid-Zone Angle Candelas 0 174 5 187 15 219 25 263 35 299 45 313 55 315 65 317 75 309 85 284 95 248 105 198 115 135 125 71 135 23 145 3 155 0 165 0 175 0 180 0 834 STIBOINFO((CRH:66008com:6L:834)) CH0 0 5 L - 4 US: 1-866-764-5454 CAN: 1-800-265-0502 ZONAL LUMENS Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Lumens 18 61 115 174 233 294 345 368 365 321 234 134 51 11 1 0 0 0 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0835-2 Name: 6L-835 100: DATE: JAN 19 2006 Time: 5:55:33 PM Operator: TB COLOR: CMYK TCP: 15001 Photometric Data EVLPF Series Compact Fluorescent Typedriver Name: TS name csm no.: 100 6L Low Profile Hazard ȿ Gard® Luminaires Luminaire with Globe and Dome (Less Guard) EVLPFA03640RD Lamp: (2) 32 W Compact Fluorescent CANDELAS Mid-Zone Angle Candelas 0 582 5 595 15 651 25 672 35 644 45 596 55 493 65 331 75 139 85 29 95 10 105 10 115 10 125 6 135 1 145 0 155 0 165 0 175 0 180 0 ZONAL LUMENS Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Lumens 57 176 291 384 450 461 347 145 31 11 10 6 1 0 0 0 0 0 Luminaire with Globe and 30° Angle Reflector (Less Guard) EVLPFA03640RA Lamp: (2) 32 W Compact Fluorescent CANDELAS Degrees 0 5 15 25 35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 180 Front Side Back 524 524 524 565 526 487 637 528 452 751 541 425 816 550 315 798 551 157 749 453 18 684 258 1 605 93 1 450 20 9 260 10 9 99 10 9 18 9 9 0 1 9 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ZONAL LUMENS Zone Lumens 0-10 51 10-20 152 20-30 255 30-40 337 40-50 371 50-60 353 60-70 301 70-80 230 80-90 144 90-100 71 100-110 15 110-120 7 120-130 2 130-140 0 140-150 0 150-160 0 160-170 0 170-180 0 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:835)) CH0 0 5 L - 4 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 835 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0836-3 Name: 6L-836 6L DATE: JAN 19 2006 Time: 5:55:38 PM Operator: TB COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div. 2, Groups B, C, D Cl. I, Zone 1, Groups IIC (Suffix S813) ɀ Cl. II, Div 1, Groups E, F, G (Suffix S813) ɀ Cl. II, Div 2, Groups F,G ɀ Cl. III, Simultaneous Presence FVS Series Long Twin Tube Fluorescent Luminaires Typedriver Name: TS name csm no.: 100 Marine & Wet Locations 3,3R, 4,4X; IP66 Application: FVS compact fluorescent luminaires are used: ɀ where low mounting heights or limited mounting room exists. ɀ for task oriented lighting. ɀ where a cool, efficient light source is required. ɀ in areas that require lamps to reach full illumination immediately. ɀ in industrial and chemical processing. ɀ in pulp and paper facilities. ɀ in waste or sewage treatment facilities. ɀ in non-hazardous commercial and industrial areas. ɀ in food and pharmaceutical plants where a non-glass lens is required. ɀ where fluorescent lighting has been preferred, but unavailable due to limited space and practicality. Features: ɀ Compact, lightweight, low profile design is ideal for confined areas and tight corners. ɀ Reaches full illumination immediately and delivers light output equivalent to fixtures twice its size. ɀ Fast-Latch TM closure provides quick and easy access for relamping and maintenance – no tools necessary. ɀ Silicone sealing gasket provides exceptional watertight and dust-tight bond, providing excellent performance in wet and corrosive environments. ɀ Power disconnect switch (Cooper CrouseHinds ESWP) automatically cuts power to the lamps and ballast when the lens is opened. ɀ Shatter-resistant polymeric lens (.125 thick) provides environmental and corrosion protection. ɀ Available in 120, 277, 220/240 and 347 50/60hz voltages. ɀ 2 lamp fixture, uses single-ended 40 watt lamps. ɀ Multiple mounting capability. ɀ Energy saving electronic ballast is standard. Standard Materials: ɀ Corrosion-resistant die cast copper-free aluminum housing. ɀ Shatter-resistant nylon lens. ɀ Polycarbonate lens (suffix-S813) ɀ Silicone rubber gasket. ɀ Extruded aluminum hinges and closure hardware with stainless steel pivots. Standard Finishes: ɀ Epoxy powder coated housing. ɀ Anodized hinges and closure hardware. ɀ Highly specular aluminum reflector. Size Ranges: ɀ All luminaires are 24⍯L x 12⍯W x 3.12⍯H. ɀ Conduit entrances are 3/4⍯. Certifications and Compliances: Accessories ɀ NEC and CEC: Class I, Division 2, Groups B,C,D Class I, Zone 1 Group IIC (suffix S813) Class II, Division 1, Groups E, F, G (Suffix S813) Class II Division 2 Groups F, G Class III & Simultaneous Presence (Cl. I and Cl. II) Note: Aiming Limitations Cl. II, Cl. III & Simultaneous Presence Aim down to Horizontal Cannot aim up ɀ UL Standards 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards C22.2 No. 137 FVS Trunnion Mount Kit (FVS-K5) ɀ Permits vertical mounting of luminaire on a beam when used with a standard beam clamp. ɀ Can be mounted directly to a wall or ceiling. ɀ Can be pole mounted when used in conjunction with a SFA6 slipfitter adapter (ordered separately). ɀ Constructed from copper-free aluminum. ɀ Supplied with a CGB cord connector. Options: Suffix to be added to Description Cat. No. ɀ Fused to protect ballast under abnormal line conditions. Not available on CSA certified fixtures.. . . . . . . . . . . . . . . . . . . . . . . S658* ɀ Fixture supplied with two F40BX/SPX35 lamps . . . . . . . . . . . . . . . . . . . . S714 ɀ Corro-free TM epoxy finish inside and out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S753 ɀ Class I, Zone 1, Group IIC and Class II, Div. 1, Groups E, F, G suitability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . S813 ɀ Tamperproof . . . consult Cooper Crouse-Hinds FVS with Trunnion Arm and Slipfitter Temperature Performance Data: Style All All Ambient Temp °C 40°C 55°C Class I Div. 2 T3C T3C Zone I T3 — Class II See Aiming T6 — Simualtaneous Presence Limitations T3C/T6 — Luminaire Weight (lbs.) without lamps ɀ Standard 2 lamp FVS . . . . . . . . . . . . . . . . 12.0 Electrical Ratings: ɀ 120-277V, 50-60 Hz ɀ 347V, 60Hz ɀ Two 40 watt long twin tube lamps 836 STIBOINFO((CRH:66008com:6L:836)) CH0 5 L - 2 7 * When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT in the catalog number. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Supply Wire 75°C 75°C Minimum Operating Temperature -18°C (0°F) -18°C (0°F) Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0837-3 Name: 6L-837 DATE: JAN 19 2006 FVS Series Long Twin Tube Fluorescent Luminaires Time: 5:55:40 PM Operator: JB COLOR: CMYK ɀ ɀ ɀ ɀ Cl. I, Div 2, Groups B,C,D Cl. I, Zone 1 Group IIC (suffix S813) ɀ Cl. II, Div 1,Groups E,F,G (suffix S813) ɀ Cl. II, Div 2, groups F,G ɀ Cl. III, Simultaneous Presence TCP: 15001 Typedriver Name: TS name csm no.: 100 Marine & Wet Locations 3,3R, 4,4X; IP66 6L Luminaire includes all necessary provisions for these installations: Ceiling Mount Pendant Mount Corner Mount FVS compact fluorescent (2 lamp luminaire): Voltage Wattage/ Lamp Hub Size (4) Cat. Number Cat. # with Class I, Zone 1 and Class II, Div. 1 Suitability 120 (50 or 60 Hz) 277 (50 or 60 Hz) 120–277 (50 or 60 Hz) 347 (50 or 60 Hz) 40 40 40 40 3⁄4⍯ FVS20 FVS27 FVS20UNV FVS23 FVS20–S813 FVS27–S813 FVS20UNV–S813 FVS23–S813 3⁄4⍯ 3⁄4⍯ 3⁄4⍯ Horizontal Wall Mount Vertical Wall Mount Accessories Separately Ordered ɀ Trunnion arm kit . . . . . . . . . . . . . . . . . FVS-K5 ɀ Slipfitter adapter to be used with trunnion arm . . . . . . . . . . . . . . . . . . . . . . SFA6 Dimensions: FVS with Trunnion Arm: 261⁄4⍯ × 13.5⍯W × 3.12⍯H Side View Top View FVS Showing Mounting Strap Positioning FVS With Lens Open US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:837)) CH0 5 L - 2 8 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 837 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0838-2 Name: 6L-838 DATE: JAN 19 2006 Time: 5:55:48 PM Operator: TB FVS Series Long Twin Tube 6L COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Fluorescent Luminaires Luminaire: FVS Lamp: (2) F40BX/SPX35/RS single-ended fluorescent. Total initial lumens: 6300 Isofootcandle Chart Coefficients of Utilization Effective Floor Cavity Reflectance 20% Eff. Ceil. 80* 70* 50* Footcandle Values for Isofootcandle Lines Mtg. Hgt. 8′ 10′ 12′ 16′ A 5.00 3.20 2.22 1.25 B 3.00 1.92 1.33 0.75 C 1.00 0.64 0.44 0.25 D 0.50 0.32 0.22 0.13 E 0.20 0.13 0.09 0.05 30* 10* 0* Wall 50* 30* 10* 50* 30* 10* 50* 30* 10* 50* 30* 10* 50* 30* 10* 0* 1 .621 .594 .569 .606 .582 .560 .580 .560 .541 .555 .539 .524 .533 .520 .507 .494 2 .538 .495 .459 .526 .487 .453 .503 .470 .442 .483 .455 .431 .464 .441 .421 .407 3 .469 .419 .378 .459 .412 .374 .441 .400 .367 .423 .389 .360 .407 .378 .353 .339 Room Cavity Ratio 4 5 6 .414 .367 .329 .359 .312 .273 .317 .270 .234 .405 .360 .323 .354 .308 .270 .314 .268 .232 .389 .347 .311 .345 .300 .265 .310 .265 .230 .374 .334 .301 .336 .293 .259 .305 .262 .227 .361 .322 .290 .327 .287 .254 .300 .258 .225 .286 .245 .212 * Percent Reflectance Spacing to Mounting Height Ratio Along lamp axis (A-A) 0.6 Across lamp axis (B-B) 1.1 * FVS suitable for Class II, Div. 1, Groups E, F, G when ordered with suffix S813. 838 STIBOINFO((CRH:66008com:6L:838)) CH0 5 L - 2 9 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 7 .297 .242 .204 .291 .240 .203 .281 .235 .201 .272 .230 .199 .264 .226 .197 .185 8 .269 .216 .180 .265 .214 .179 .256 .210 .178 .248 .207 .176 .241 .203 .175 .163 9 .246 .195 .160 .242 .193 .160 .234 .190 .159 .227 .187 .157 .221 .184 .156 .145 10 .225 .176 .144 .222 .175 .143 .216 .172 .143 .210 .170 .142 .204 .167 .141 .130 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0839-3 Name: 6L-839 100: DATE: JAN 19 2006 EVFT Illuminator TM Long Twin Tube Fluorescent Luminaires Time: 5:55:49 PM Operator: TB COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div, Groups B & C(suffix GB), D Cl. I, Zone 1 Group IIB + H2(suffix GB), IIA ɀ Cl. II, Div 1, Groups E,F,G ɀ Cl. III Simultaneous Presence Typedriver Name: TS name csm no.: 100 Paint Spray Marine & Wet Locations ɀ 3,3R, 4,4X; IP66 6L Application: Illuminator TM compact fluorescent luminaires are used: ɀ In areas made hazardous by the presence of flammable gases and vapors, combustible dusts, or easily ignitable fibers and flyings. ɀ In areas where combustible dusts and flammable gases are present simultaneously. ɀ In applications involving low mounting heights, restricted mounting space, or where luminaire weight must be minimized. ɀ In areas where corrosion, vibration, moisture, dirt and rough usage are a problem. ɀ In refineries, chemical and petrochemical facilities, grain processing, handling and storage facilities, manufacturing plants, waste water treatment facilities, airline and mass transit maintenance areas, paint spray facilities, breweries, pharmaceutical plants and other areas where safe, reliable hazardous area lighting is required in a compact, cool operating and efficient light source. Features: ɀ Efficient fluorescent light source in 78 and 156 watts. ɀ Adjustable right and left asymmetrical reflectors provide excellent light ‘‘aimability’’ – ideal for task oriented lighting. ɀ Compact, light weight and low profile design allows easy installation and broad industrial application. ɀ Cast copper-free aluminum with epoxy powder finish (less than 0.4 of 1% copper) provides excellent resistance to corrosion. ɀ Versatile luminaire housing provides choice of pendant, wall or ceiling mount. ɀ Suitable for paint spray areas. Linear light source provides excellent color rendition for paint spray tasks. Easy to install, disposable, clear tube wrap helps maintain maximum light output during painting operations. ɀ Threaded construction, factory wiring and sealing help minimize installation time. No external seals are required. ɀ Fixtures are used with two or four long twin tube single-ended fluorescent lamps. ɀ Optional stainless steel guard provides extra protection for lamps and lamp tube. ɀ Optional clear polycarbonate tube provides 360° protection for lamps and lamp tube; ideal for maintenance pit and pharmaceutical applications. ɀ Grounding connection for safety. ɀ Available for 120 or 277 VAC. ɀ Standard electronic ballast. 4 lamp with stainless steel wire guard and adjustable reflectors Certifications and Compliances: Electrical Ratings: ɀ NEC and CEC: Class I, Division 1 Group D Class I, Division 1 Group B,C,D (suffix GB) Class I, Zone 1 Group IIA Class I, Zone 1 Group IIB + H2 (suffix GB) Class II Groups E,F,G Class III Simultaneous Presence (Cl. I and Cl. II) Paint Spray Note: Aiming Limitations Cl. II, Cl III & Simultaneous Presence – Aim Down to Horizontal – Cannot aim up ɀ UL Standards 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards C22.2 No. 137 ɀ Input voltage – 120 or 277 VAC, 60Hz ɀ Wattages – 78 – 2-lamp luminaire 156 – 4-lamp luminaire Options: Suffix to be added to Catalog Number ɀ Fused to protect circuit under abnormal conditions (not available on CSA certified luminaires). . . . . . . . . . . . . . . . . . . . . . . . . S658* ɀ Luminaire supplied with lamps . . . . . . . S714 ɀ Class I, Groups B and C suitability Pendant mount only! . . . . . . . . . . . . . . . . . GB Fixture Weights (lbs.): Illuminator – 2 lamp with guard . . . . . . . . . 19.5 Illuminator – 4 lamp with guards . . . . . . . . 36.5 RAL1, RAR1 reflectors (each) . . . . . . . . . . . . 3.0 Deduct for luminaire without P51 Guard: 1 lb. for 2 lamp 2 lbs. for 4 lamp Standard Materials: ɀ Center and ballast housings, end caps – copper-free aluminum ɀ Lamp tube – heat resistant glass. ɀ Guards – stainless steel or clear polycarbonate material. ɀ Reflectors – aluminum Standard Finishes: ɀ Center and ballast housings, end caps, guards – natural ɀ Reflectors – white epoxy finish Temperature Performance Data: Luminaire Type Minimum Operating Temp. Maximum Ambient Temp. Class I, Division 1 & Zone 1 Class II, Division 1 Simultaneous Presence Supply Wire 2 and 4 Lamp 10°C (50°F) 40°C (104°F) T4A 75°C * When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT in the catalog number. US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:839)) CH0 5 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 839 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0840-2 Name: 6L-840 6L DATE: JAN 19 2006 EVFT Illuminator TM Long Twin Tube Fluorescent Luminaires Time: 5:55:53 PM Operator: TB COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div 1, Groups B & C (Suffix B),D Cl. I, Zone 1, Groups IIB + H2 (Suffix B), IIA ɀ Cl. II, Div 1, Groups E, F, G ɀ Cl. III, Simultaneous Presence Typedriver Name: TS name csm no.: 100 Paint Spray Marine & Wet Locations ɀ 3,3R, 4,4X; IP66 EVFT Illuminator Hub Size 3⁄4 2 Lamp 3 ⁄4 3⁄4 4 Lamp 3 ⁄4 Style Luminaire Voltage 120 277 120 277 Class I Cat. No. with Group D Suitability Without With Guard P51 Guard† EVFT22320 EVFT22321 EVFT22370 EVFT22371 EVFT24320 EVFT24321 EVFT24370 EVFT24371 Class I Cat. No. with Group B, C & D Suitability Without With Guard P51 Guard† EVFT22320–GB EVFT22321–GB EVFT22370–GB EVFT22371–GB EVFT24320–GB EVFT24321–GB EVFT24370–GB EVFT24371–GB † P51 supplied in separate carton. Accessories ɀ Stainless steel wire guard . . . . . . . . . . . . P51 ɀ Reflector right hand . . . . . . . . . . . . . . . . RAR1 ɀ Reflector left hand . . . . . . . . . . . . . . . . . . RAL1 ɀ Polycarbonate tube . . . . . . . . . . . . . . . . . PG1 (not used with optional stainless steel wire guard) ɀ Disposable clear wrap – 5 pack. . . . . . PTW1 (for use with optional polycarbonate tube) Note: Aiming Limitations: In Class II, Class III and Simultaneous Presence locations ɀ Aim down to Horizontal. ɀ To prevent dust from accumulating in reflector, do not aim up. Dimensions Illuminator two lamp luminaire with Reflector RAR1 RAL1 Reflectors (as viewed facing front of fixture). Stainless steel guard Illuminator four lamp luminaire with Reflectors Polycarbonate tube and retaining plate ɀ For GB suffix (Groups B & C) this dimension is 34.0⍯. For CSA certified fixtures this dimension is 359⁄16⍯. ɍ For GB suffix (Groups B & C) this dimension is 8.38⍯. Disposable polyester tube wrap (used over optional polycarbonate tube) 840 STIBOINFO((CRH:66008com:6L:840)) CH0 5 L - 3 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0841-3 Name: 6L-841 DATE: JAN 19 2006 Time: 5:55:55 PM Operator: TB COLOR: CMYK TCP: 15001 Photometric Data EVFT Illuminator TM Long Twin Tube Typedriver Name: TS name csm no.: 100 6L Fluorescent Luminiaires Illuminator two lamp luminaire with Reflector (without Guard) Lamps: (2) 39 watt BIAX* fluorescent DEGREES 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 CANDELAS in Plane A-A LEFT RIGHT 729 729 792 797 820 821 757 777 648 709 567 632 474 535 340 469 201 312 102 116 9 7 Plane B-B SIDE 729 703 658 582 488 370 239 109 21 LEGEND PLANE A-A ACROSS LAMP AXIS – – – – PLANE B-B ALONG LAMP AXIS Footcandle Values for Isofootcandle Lines MTG. HT (FT) A B C D E F 8 10.0 5.00 2.00 1.00 0.50 0.25 10 6.4 3.20 1.28 0.64 0.32 0.16 12 4.4 2.22 0.89 0.44 0.22 0.11 16 2.5 1.25 0.50 0.25 0.13 0.06 Illuminator four lamp luminaire with Reflectors (without Guards) Lamps: (4) 39 watt BIAX* fluorescent DEGREES 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 CANDELAS in Plane A-A LEFT RIGHT 1486 1486 1601 1520 1633 1615 1570 1602 1530 1558 1343 1390 1162 1208 803 921 375 488 136 168 13 18 2 6 1 4 2 1 2 2 1 2 Plane B-B SIDE 1486 1448 1346 1199 1000 763 492 225 45 2 1 1 1 1 1 2 LEGEND PLANE A-A ACROSS LAMP AXIS – – – – PLANE B-B ALONG LAMP AXIS Footcandle Values for Isofootcandle Lines MTG HT (FT) A B C D E F 10 8.0 4.00 2.00 1.00 0.50 0.20 12 5.6 2.78 1.39 0.69 0.35 0.14 16 3.1 1.56 0.78 0.39 0.20 0.08 20 2.0 1.00 0.50 0.25 0.13 0.05 * BIAX is a trademark of the General Electric Company. US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:841)) CH0 5 L - 3 2 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 841 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0842-2 Name: 6L-842 DATE: JAN 19 2006 Time: 5:55:56 PM Operator: TB TCP: 15001 Typedriver Name: TS name csm no.: 100 Coefficients of Utilization EVFT Illuminator TM Long Twin Tube 6L COLOR: CMYK Fluorescent Luminaires LUMINAIRE: EVFT 22320 with RAR1 Reflector Lamps: Two (2) F39BX/SPX35/RS Lumen Rating: 2900 Lumens/Lamp Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 0 1 2 3 Room Cavity Ratio 4 5 6 7 8 9 10 80 70 50 30 10 .51 .51 .51 .51 .46 .44 .41 .40 .41 .38 .35 .32 .38 .33 .29 .26 .34 .29 .25 .22 .31 .25 .21 .18 .29 .23 .19 .16 .26 .20 .16 .14 .24 .18 .14 .12 .22 .16 .13 .10 .21 .15 .11 .09 70 70 50 30 10 .49 .49 .49 .49 .45 .43 .41 .39 .40 .37 .34 .31 .37 .32 .29 .26 .33 .28 .25 .22 .30 .25 .21 .18 .28 .22 .18 .16 .26 .20 .16 .14 .24 .18 .14 .12 .22 .16 .12 .10 .20 .14 .11 .09 50 50 30 10 .47 .47 .47 .41 .39 .38 .35 .33 .31 .31 .28 .26 .27 .24 .22 .24 .21 .18 .21 .18 .16 .19 .16 .13 .17 .14 .12 .15 .12 .10 .14 .11 .09 30 50 30 10 .45 .45 .45 .39 .38 .37 .34 .32 .30 .30 .27 .25 .26 .24 .21 .23 .20 .18 .21 .18 .15 .19 .16 .13 .17 .14 .11 .15 .12 .10 .14 .11 .09 10 50 30 10 .43 .43 .43 .37 .36 .35 .33 .31 .29 .29 .27 .25 .25 .23 .21 .22 .20 .18 .20 .17 .15 .18 .15 .13 .16 .13 .11 .14 .12 .10 .13 .10 .08 0 0 .43 .35 .28 .24 .20 .17 .14 .12 .10 .09 .08 DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE: EVFT 24320 with RAR1 & RAL1 Reflectors Lamps: Four (4) F39BX/SPX35/RS Lumen Rating: 2900 Lumens/Lamp Effective Floor Cavity Reflectance 20% % Reflectance Eff. Ceil. Wall 0 1 2 3 Room Cavity Ratio 4 5 6 7 8 9 10 80 70 50 30 10 48 .48 .48 .48 .44 .42 .40 .39 .40 .37 .34 .31 .37 .32 .29 .26 .33 .29 .25 .22 .30 .25 .21 .19 .28 .22 .19 .16 .26 .20 .16 .14 .24 .18 .14 .12 .22 .16 .13 .10 .20 .15 .11 .09 70 70 50 30 10 .47 .47 .47 .47 .43 .41 .40 .38 .39 .36 .33 .31 .36 .32 .29 .26 .33 .28 .25 .22 .29 .25 .21 .18 .27 .22 .18 .16 .25 .20 .16 .14 .23 .18 .14 .12 .21 .16 .12 .10 .20 .14 .11 .09 50 50 30 10 .45 .45 .45 .39 .38 .37 .34 .32 .30 .30 .28 .26 .27 .24 .22 .24 .21 .18 .21 .18 .16 .19 .16 .14 .17 .14 .12 .15 .12 .10 .14 .11 .09 30 50 30 10 .43 .43 .43 .38 .37 .36 .33 .31 .30 .29 .27 .25 .26 .23 .21 .23 .20 .18 .20 .18 .16 .18 .16 .13 .17 .14 .12 .15 .12 .10 .14 .11 .09 10 50 30 10 .41 .41 .41 .36 .35 .35 .32 .30 .29 .28 .26 .25 .25 .23 .21 .22 .20 .18 .20 .17 .15 .18 .15 .13 .16 .13 .12 .14 .12 .10 .13 .11 .09 0 0 .41 .34 .28 .24 .20 .17 .15 .13 .11 .09 .08 DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES 842 STIBOINFO((CRH:66008com:6L:842)) CH0 5 L - 3 3 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0843-11 Name: 6L-843 DATE: JAN 19 2006 Time: 5:55:57 PM Operator: JB COLOR: CMYK ɀ ɀ ɀ ɀ Higher Ambient Suitability: 55°C Cold Weather Start (32W T8 Lamps) ɀ Cl. I, Div 2, Groups A, B, C, D ɀ Cl. I, Zone 2 Group IIC NFL Series Fluorescent Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 Wet Locations 3, 3R, 4, 4X 6L Application: The NFL light luminaires are used: ɀ In non-hazardous locations where dust, dirt, combustible vapors, smoke, fumes, moisture, corrosive & wet conditions are present. ɀ Where lamps may be broken due to physical abuse or movable equipment, such as in manufacturing areas or warehouses. ɀ Where cleanliness and sanitation are prime factors such as in dairies, canneries, food processing plants, bottling plants & laboratories. ɀ In dock areas for protection against salt spray. ɀ In areas where low mounting height and the even light distribution associated with a line type light source are required. Standard Materials: ɀ Housing – Non-metallic, one piece fiberglass reinforced polyester ɀ Latches – Celcon TM acetal plastic ɀ Crepe Pattern Lens – Acrylic plastic ɀ Gasket – Seamless thermoset polyurethane ɀ Mounting Bracket – Stainless steel Standard Finishes: ɀ Fiberglass housing – White ɀ Acrylic Plastic lens – Clear Key Features ɀ Molded in place mounting studs – eliminate the need of bracket gaskets ɀ Standard construction includes: S.S. mounting brackets Electronic ballast Cold weather ballast (4′ F32 T8) ɀ S.S. mounting bracket Combination ceiling & chain Certifications and Compliances: ɀ UL Listed 844 ɀ cUL ɀ Wet locations ɀ 4X Ratings (Electrical/Size): Sources/Wattage: Luminaires are for use with the following lamps ɀ NFL2140 – one 40 W long twin tube ɀ NFL4232 – two 32W T8 lamps ɀ NFL4240 – two 34W ‘‘F40 Style’’ T12 lamps Voltages ɀ 120V 60Hz ɀ 120 - 277V, 50 - 60 Hz ɀ 347V 60Hz Conduit Entries ɀ Two 1⁄2⍯ inch Myers hubs, one on each end. ɀ S.S. mounting brackets ɀ Electronic Ballast ɀ Cold Weather Ballast (4′ F32 T8) ɀ Two 1⁄2⍯ conduit Myers hubs for end and feed through wiring ɀ Full metal fixture interior ɀ Provisions (drill mark) on 4 ft. unit to field drill for pendant mounting Options: Description Suffix to be added to Cat. No. ɀ Fused . . . . . . . . . . . . . . . . . . . . . . . . .S658‡ ɀ Factory assembled with lamps installed . . . . . . . . . . . . . . . . . . . . . . . . .FA ɀ Battery Backup Emergency Ballast † (NFL 2140 and NFL 4232 only) . . . . .S799* ɀ Increased Impact-Resistant Acrylic Lens . . . . . . . . . . . . . . . . . . . . .DR1295046* ɀ Polycarbonate Lens . . . . . . . . . . . . .DR1295306* ɀ Stainless Steel Latches . . . . . . . . . .S863* ɀ Tamperproof Latches . . . . . . . . . . .S861* – available with Lightning Service TMdelivery See Section G for complete details † For non-hazardous locations ‡ When ordering Fuses for luminaires, option S658, you must specify the operating voltage. S658 can not be ordered with /MT in the catalog number. * UNV voltages: 120, 208, 230, 240, 277, 50-60 Hz US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:843)) CH0 0 5 L - 3 Benefits ɀ UL, cUL Listed for Class I, Division 2, Groups A, B, C, D areas with ambient suitability of 40°C (104°F) and 55°C (131°F) Ambient suitability ɀ NEMA 4X with Myers Hubs and threaded metal plug (furnished) ɀ Non-metallic construction enclosure ɀ Continuous form in place gasket Suitable for higher ambients found in industrial environments. Exceeds the 25°C (77°F) ambient suitability of ordinary location lighting fixtures. Outdoor locations, hose down and corrosive environments suitable. Corrosion resistant. Insure dust tight, moisture tight, & wet locations integrity. Wet locations, and dust tight integrity is not compromised by aging or deteriorated bracket gaskets. Eliminates the need to order options with associated long lead times. Standard bracket not only surface mounts fixture, but also is for chain mounting using standard commercially available fixture chain. Superior corrosion resistance. Energy efficiency. Cold weather start up requirements. Simplify installation and wiring. Provides improved photometrics as well as access to & concealment of ballast and wiring. Application and installation flexibility. Temperature Performance Data: Ambient temperature range suitability: ɀ Two lamp, 32W T8, 4 ft luminaire –18°C to 55°C ɀ ALL others 0°C to 55°C ɀ Supply wire 75°C min. Celecon TM is a trade name of Hoechst Celanese Ordering Information: Luminaire Cat # Size/# of lamp(s) Wattage/Lamp type Voltage/Hz NFL2140/UNV 2 ft/ 1-lamp 40W T5 compact 120/60 NFL2140/347 single ended 120-277/50-60 347/60 NFL4232/UNV 4 ft/2-lamp 32W T8 120/60 rapid start 120-277/50-60 NFL4240/120 4ft/2-lamp 34W T12 120/60 NFL4240/277 ‘‘F40 Style’’ 277/60 NFL4240/347 rapid start 347/60 N2FL4232/UNV N2FL4232/347 4ft/2-lamp 32W T8 347/60 rapid start CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 843 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0844-2 Name: 6L-844 6L 100: DATE: JAN 19 2006 Time: 5:55:58 PM Operator: TB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data NFL Series Fluorescent Luminaires Luminaire: All NFL Luminaires To determine number and placement of luminaires, see Lighting Selector Guide in Section L Candlepower Distribution Curve (in Candelas) CANDELAS Angle Along Across 0° 1049 1049 10° 1034 1056 20° 978 1071 30° 866 1075 40° 762 1027 50° 606 939 60° 416 838 70° 228 723 80° 92 549 90° 17 363 100° 19 243 110° 10 131 120° 5 46 130° 4 20 140° 4 9 150° 4 3 160° 4 0 170° 0 0 180° 0 0 ZONAL LUMENS Zone Lumens 0–30 862 0–40 1462 0–60 2778 0–90 4130 0–180 4499 Photometric data, developed using two (2) F32T8/35K 2850 lumen lamps, represents the performance of all NFL series luminaires. ɀ Coefficient of Utilization – These values are for all NFL series luminaires (Do not use multipliers). ɀ Candlepower Distribution Cuarve (in candelas) and Zonal Lumens – These values are for all NFL series luminaires, adjusted by conversion factors (multipliers) below. Luminaire Lamp Series Qty Watts NFL4232 2 32 NFL4240 2 34 NFL2140 1 40 Type (Lumens ea.) F32T8/35K (2850) F40T12/RS (2650) T5 Compact (3150) Conversion Factor (multipliers) 1.0 0.93 0.55 Example: ɀ Candlepower at 20° across for NFL4232 using 2F32T/35K lamps (5700 lumen total) is 1071 candelas. ɀ Candlepower at 20° across for NFL2140 using 1 T5 compact lamp (3100 lumen total) is 1071 x .55 ⍧ 589 candelas. Coefficient of Utilization: For all NFL Series Light Luminaires Effective Floor Cavity Reflectance 20% % REFLECTANCE Eff. Ceiling Wall 70 80 50 30 10 70 70 50 30 10 50 50 30 10 50 30 30 10 50 10 30 10 0 0 844 STIBOINFO((CRH:66008com:6L:844)) CH0 0 5 L - 4 1 .83 .78 .74 .71 .80 .76 .72 .69 .71 .68 .66 .67 .65 .62 .63 .61 .59 .57 2 .75 .67 .61 .56 .72 .65 .60 .55 .61 .57 .53 .58 .54 .51 .54 .51 .48 .46 US: 1-866-764-5454 3 .68 .59 .52 .46 .65 .57 .51 .46 .54 .48 .44 .51 .46 .42 .48 .44 .41 .39 4 .62 .52 .44 .39 .59 .50 .43 .38 .47 .42 .37 .45 .40 .36 .42 .38 .35 .33 CAN: 1-800-265-0502 ROOM CAVITY RATIO 5 6 .56 .51 .45 .40 .38 .33 .32 .28 .54 .49 .44 .39 .37 .32 .32 .27 .42 .37 .35 .31 .31 .26 .39 .35 .34 .30 .30 .26 .37 .33 .33 .29 .29 .25 .27 .23 7 .47 .36 .29 .24 .46 .35 .28 .23 .33 .27 .23 .32 .26 .22 .30 .25 .22 .20 Copyright© 2006 Cooper Crouse-Hinds 8 .44 .32 .25 .20 .42 .31 .25 .20 .30 .24 .20 .28 .23 .19 .27 .22 .18 .17 9 .40 .29 .22 .17 .39 .28 .22 .17 .27 .21 .17 .25 .20 .16 .24 .19 .16 .14 10 .37 .26 .20 .15 .36 .26 .19 .15 .24 .19 .15 .23 .18 .14 .22 .17 .14 .12 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0845-5 Name: 6L-845 100: DATE: JAN 19 2006 Time: 5:55:59 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Dimensions and Weights NFL Series Fluorescent Luminaires 6L Dimensions: Net Luminaire Weights (lbs) Luminaire Series NFL2140 NFL4232 NFL4240 Weight (lbs.) 9.1 14.3 14.3 Temperature Performance Data Basic Watts Cat # Ambient Temp °C Lamp Type Supply Wire Temp °C Class I, Div. 2 Temp. Rating Class II Temp. Rating NFL4232 NFL4232 NFL4240 NFL4240 NFL2140 NFL2140 40 55 40 55 40 55 T8 T8 T12 T12 T12 T12 60 75 60 75 60 75 T6 T5 T6 T5 T6 T5 - 32 32 34 34 40 40 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:845)) CH0 0 5 L - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Simultaneous Presence Class 1, Div. 2 - 845 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0846-11 Name: 6L-846 6L DATE: JAN 19 2006 Time: 5:56:00 PM Operator: GK COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div 2, Groups B,C,D Cl. I, Zone 1 Group IIC ɀ Cl. II, Div Groups E,F,G(Canada) ɀ Cl. II, Div 2, Groups F,G (US) ɀ Cl. III, Simultaneous Presence eLLK Series Fluorescent Nonmetallic Luminaires Typedriver Name: TS name csm no.: 100 Wet Locations 3,3R,4,4X; IP66 ɀ ATEX Certified Application: ɀ eLLK fixtures are used in hazardous area where moisture or corrosion may be a problem. ɀ Offshore oil platforms, Pharmaceuticals, plants, Oil refineries. ɀ Where battery backup is critical. ɀ In non-hazardous and industrial locations. Features: ɀ IEC: Zone 1 and 2 areas. ɀ NEC/CEC: Zone 1, Division 2 areas. ɀ Electronic Ballast: ɀ Operates at Voltage range of 110-254 VAC ± 10%, 50-60Hz. ɀ Lower ambient temperature suitability to –25°C. ɀ Lamps operate indepenently - one lamp failure will not effect remaining lamp operation. ɀ Standard Bi-pin Lamps - Most common lamp used in office enviroments. Energy efficient and cost effective. ɀ Interlocked Switch - Automatically cuts power to both lamps and ballast when the lens is opened. ɀ Removable Lens - Hinged on both sides for easy installation and maintenance. ɀ Dual entries - Extra large wire well eliminates need for seperate junction boxes. (Own with cable gland and conduit hub). ɀ Corrosion-Resistant Construction - Nonmetallic body, gasketed lenses, and lens locking system for an IP 66, NEMA 4X rating. ɀ Battery Backup Features: ɀ Operates one lamp for 11⁄2 hours should power go out. ɀ Microprocessor monitors the charging functions of the battery. ɀ LEDs provide visual indication of battery life. Certifications and Compliances: ɀ NEC and CEC: Class I, Division 2 Group B, C, D Class I, Zone 1 Group IIC Class II Division 1, Groups E,F,G (Canada) Class II Division 2, Groups F, G (US) Class III, Simultaneous Presence (Cl. I and Cl. II) ɀ UL Standards 2279 Hazardous (Classified) Locations 1598 Luminaires ɀ CSA Standards E79 Series II 2 G ɀ ATEX Directive 94/9/EC II 2 D T80°C ɀ Type of Protection EEx edm ib IIC T4 ɀ EC-Type Examination PTB 96 ATEX 2144 Certificate Ordering Information: Type - 2 Lamp 18W 36W 18W 18W (with battery) 18W (with battery) 36W 36W (with battery) 36W (with battery) Length & Type 2-foot T8 4-foot T8 2-foot T8 2-foot T8 2-foot T8 4-foot T8 4-foot T8 4-foot T8 Conduit Hub Size* M25 metric hub M25 metric hub 3/4⍯ Myers hub 3/4⍯ Myers hub 3/4⍯ Myers hub 3/4⍯ Myers hub 3/4⍯ Myers hub 3/4⍯ Myers hub Rated Current 0.18A 0.34A 0.18A 0.23A 0.23A 0.34A 0.40A 0.40A Rated Voltage ±10%, 47-63Hz 110-254 110-254 110-254 110-120 220-254 110-254 110-120 220-254 Order Number 1 2265 875 103 1 2266 875 103 1 2265 875 311 1 2260 879 333 1 2260 879 311 1 2266 875 311 1 2261 879 333 1 2261 879 311 Description eLLK92018/UNV eLLK92036/UNV eLLK92018/UNV eLLK92018/18/NIB eLLK92018/18/NIB WH eLLK92032/UNV eLLK92036/36/NIB eLLK92036/36/NIB * 2 hubs provided. May be connected throughfeed or tandam. Cable glands ordered separately for 3⁄4⍯ (remove hubs) or M 25 openings (remove hubs). Lamp Selection: Phillips GE Osram/Sylvania 846 STIBOINFO((CRH:66008com:6L:846)) CH0 5 L - 3 0 Weight 17W 32W F17T8/Tl841 F17T8/SPX41 F017/841 F32T8/TL841 F32T8/SPX41 FO32/841 US: 1-866-764-5454 CAN: 1-800-265-0502 17 W 17 W (battery) 32 W 32 W Copyright© 2006 Cooper Crouse-Hinds 4.6 Kg (10 Ib) 10 Kg (22 Ib) 6.7 Kg (14 Ib) 12 Kg (26 Ib) Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0847-4 Name: 6L-847 100: DATE: JAN 19 2006 Time: 5:56:01 PM Operator: JB TCP: 15001 Typedriver Name: TS name csm no.: 100 Accessories Dimensions eLLK Series TM Fluorescent Nonmetallic Luminaires Accessories COLOR: CMYK 6L Dimensions: (mm) Standard Luminaire with Backup Eyebolt Hexagonal Screw Type Eyebolt Hexagon Screw S4 Ceiling Mounting D92 Bracket Pipe Clamp Ceiling Mounting Bracket Corrosion Protection Galvanized Cr Ni Pipe Outer Quantity per Din OD (mm) Luminaire — — 2 — — 2 Order Number 2 2480 002 000 2 2480 054 000 Cr Ni R12 Hot Galvanized R14 CrNi R22 Hot Galvanized R32 Hot Galvanized — 11⁄4⍯ 11⁄4⍯ 11⁄2⍯ 2⍯ — 38–42 38–42 47–51 56–60 2 2 2 2 2 2 2480 092 000 2 2480 462 000 2 2480 464 000 2 2480 472 000 2 2480 482 000 — — — — 3 2485 000 005 Hexagon Key SW13 eLLK 92 Pipe Clamp Wall Bracket US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:847)) CH0 5 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 847 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0848-2 Name: 6L-848 DATE: JAN 19 2006 Time: 5:57:02 PM Operator: TB TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data eLLK Series TM Fluorescent Nonmetallic Luminaires 6L COLOR: CMYK Photometric data developed using 2 – F32T8 3350 lumen lamps. For the 17 W eLLK, use a 0.45 multiplier. Coefficients of Utilization Effective Floor Cavity Reflectance 20% Wall 70* 50* 30* 10* Work 20* 20* 20* 20* Room Cavity Ratio 1 2 3 41 49 55 30 38 44 23 30 36 18 25 30 4 61 50 43 37 5 65 55 48 42 6 70 62 55 50 7 74 67 61 56 8 77 71 65 61 9 80 75 70 66 70* 50* 30* 10* 20* 20* 20* 20* 40 29 22 18 47 37 30 24 53 42 35 30 58 49 42 36 62 54 47 42 68 60 54 49 71 65 59 54 74 68 64 59 77 72 68 64 50* 50* 30* 10* 20* 20* 20* 27 21 17 35 28 24 40 34 29 46 40 35 50 45 40 56 51 47 61 56 52 64 60 57 68 64 61 30* 50* 30* 10* 20* 30* 20* 26 20 17 38 27 23 37 32 28 43 38 34 47 43 39 58 49 45 57 53 50 60 57 54 64 61 58 10* 50* 30* 10* 20* 20* 20* 24 20 16 31 26 22 35 31 27 41 36 33 45 41 37 50 46 43 54 51 48 57 54 52 60 68 55 0* 0* 20* 14 20 25 31 35 41 46 49 53 Eff. Ceil. 80* 70* * Percent Reflectance 848 STIBOINFO((CRH:66008com:6L:848)) CH0 5 L - 3 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0849-16 Name: 6L-849 100: DATE: JAN 19 2006 Time: 5:57:03 PM Operator: JB COLOR: CMYK CI.I, Div. 2, Groups A,B,C,D CI.I, Zone 2 Aex nA II CI.II, Division 2, Groups F,G Enclosure Type 4X nLLK Series Nonmetallic Flourescent Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 Wet Locations UL and cUL Listed ATEX Certified 6L The Cooper Crouse-Hinds SpecOne TM nLLK Series Fluorescent Luminaire is an ideal source of general illumination indoors or out, in ordinary or hazardous environments. Its heavy-duty, nonmetallic construction stands up to tough physical and environmental demands, making it an excellent choice where dust, dirt, gas, vapor, smoke, fumes, moisture, corrosive and wet conditions are present. As with all SpecOne products, the nLLK luminaire meets the standards and codes of regulating agencies throughout the world, which simplifies product specifying for multinational users. APPLICATIONS nLLK series luminaires are used: In indoor or outdoor, ordinary or hazardous areas Where a heavy-duty, nonmetallic luminaire is required to hold up to tough physical and environmental demands including corrosives, water, dust and extreme temperatures ɀ manufacturing plants ɀ heavy industrial facilities ɀ industrial process facilities ɀ refineries ɀ chemical ɀ petrochemical ɀ pharmaceutical ɀ waste water and sewage treatment plants In areas where low mounting height, immediate full illumination, and the even light distribution associated with a linetype light source are required ɀ loading docks ɀ tunnels ɀ stairways Where wet location or Type 4X protection is required ɀ dock areas ɀ production platforms In hosedown areas where cleanliness and sanitation are prime factors ɀ dairies ɀ canneries ɀ food processing plants ɀ bottling plants ɀ laboratories CERTIFICATIONS & COMPLIANCES NEC ɀ Class I, Division 2, Groups A, B, C, D ɀ Class I, Zone 2 AEx nA II ɀ Class II, Division 2, Groups F, G ɀ Wet Locations ɀ UL Listed CEC ɀ Class I, Zone 2 Ex nA II ɀ Class I, Division 2, Groups A, B, C, D ɀ Class II, Division I, Groups E, F, G ɀ cUL Listed (certified by UL) Enclosure ɀ Type 4X ɀ IP65 UL Standards ɀ 2279 Hazardous (Zones Classified) Locations ɀ 1598 Luminaires CSA Standards ɀ C22.2 No. 9 ɀ CAN/CSA–E79-15 STIBOINFO((CRH:66008com:6L:849)) ɀ one-piece housing—fiber-glass reinforced polyester ɀ lens—polycarbonate ɀ gasket—silicone STANDARD FINISHES ɀ fiberglass housing—natural (white) ɀ lens—natural (clear) RATINGS (ELECTRICAL/ SIZE) Sources/Wattages ɀ two 17 W or two 32 W linear fluorescent Voltages ɀ 120–277 V, 50–60 Hz. ɀ 347 V, 60 Hz.—consult factory Hub Size ɀ four 25 mm entries, two on each end, three plugged ɀ two Myers® STM2 25 mm to 3⁄4⍯ NPT adapter hubs provided standardfor throughfeed or tandem wiring ATEX ɀ ATEX Directive 94/9/EC ɀ Type of Protection ɀ EC-Type Examination Certificate ɀ EC-Type Examination Certificate US: 1-866-764-5454 CH0 5 L - 3 0 STANDARD MATERIALS CAN: 1-800-265-0502 II 3 G II 2 D/II 3 D T80°C EEx nA II T4 nach EN 50021 PTB 96 ATEX 2208 DMT 02 ATEX E116 Copyright© 2006 Cooper Crouse-Hinds 849 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0850-23 Name: 6L-850 6L DATE: JAN 19 2006 Time: 5:57:04 PM Operator: JB COLOR: CMYK TCP: 15001 CI.I, Div. 2, Groups A,B,C,D CI.I, Zone 2 Aex nA II CI.II, Division 2, Groups F,G Enclosure Type 4X nLLK Series Nonmetallic Flourescent Luminaires Typedriver Name: TS name csm no.: 100 Wet Locations UL and cUL Listed IP65, Type 4X heavy-duty construction ɀ nonmetallic body, gasketed lens and unique labyrinth lens locking system ɀ dust-tight, water-tight and moisture-tight ɀ corrosion and impact-resistant ɀ ideal for outdoor applications Electronic ballast ɀ lower ambient temperatures suitability to -18°C ɀ high–power factor ballast (+90%) allows for more luminaires per circuit Standard T8 bi-pin lamps—most common lamp used; energy-efficient and cost-effective Removable lens—hinged on both sides for easy installation and maintenance Easy wiring and installation— ɀ four 25 mm entries. Two Myers® 3⁄4⍯ NPT adapter hubs supplied standard ɀ suitable for through-feed or tandem applications ɀ extra-large wire well eliminates need for separate junction boxes Worldwide suitability ɀ NEC/CEC: Class I, Zone 2 and Division 2 areas ɀ IEC/CENELEC certified luminaires available. Consult factory. ORDERING INFORMATION HUB SIZE* 3⁄4⍯ NPT 3⁄4⍯ NPT * 25 mm entries—supplied with two Myers LAMP DESCRIPTION 17 W T8, Rapid Start—2 lamps 32 W T8, Rapid Start—2 lamps ® VOLTAGE/HZ. 120–277 V, 60 Hz. 120–277 V, 60 Hz. CATALOG NO. nLLK98 2217/UNV nLLK98 4232/UNV STM2 25 mm to 3⁄4⍯ NPT adapter hubs. ACCESSORIES DESCRIPTION SW13 hexagon key (for maintenance and lamp replacement) Myers® 25 mm to 3⁄4⍯ NPT adapter hub CATALOG NO. 3 2485 000 005 STM2 MOUNTING ACCESSORIES TYPE CORROSION PROTECTION Eyebolt A2 Galvanized Hexagon Screw S4 (to attach ceiling mounting bracket or pipe clamp to Nickel Chromium luminaire) Ceiling Mounting Bracket D92 Nickel Chromium Pipe Clamp R12 Hot Galvanized Pipe Clamp R14 Nickel Chromium Pipe Clamp R22 Hot Galvanized Pipe Clamp R32 Hot Galvanized 850 STIBOINFO((CRH:66008com:6L:850)) CH0 5 L - 3 0 US: 1-866-764-5454 PIPE DIN 11⁄4⍯ 11⁄4⍯ 11⁄2⍯ 2⍯ CAN: 1-800-265-0502 OUTER DIA. 38–42 mm 38–42 mm 47–51 mm 56–60 mm QTY. PER LUMINIARE 2 CATALOG NO. 2 2480 002 000 2 2 2 2 2 2 2 2480 054 000 2 2480 092 000 2 2480 462 000 2 2480 464 000 2 2480 472 000 2 2480 482 000 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0851-27 Name: 6L-851 100: DATE: JAN 19 2006 Time: 5:57:05 PM Operator: JB COLOR: CMYK CI.I, Div. 2, Groups A,B,C,D CI.I, Zone 2 Aex nA II CI.II, Division 2, Groups F,G Enclosure Type 4X nLLK Series Nonmetallic Flourescent Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 Wet Locations UL and cUL Listed 6L PHOTOMETRIC DATA TEMPERATURE PERFORMANCE Minimum Starting Temperature: -18°C WATTS AMBIENT CLASS I, DIV. 2 (CLASS I, ZONE 2) CLASS II, DIV. 1 (CEC) CLASS II, DIV. 2 (NEC) SUPPLY WIRE TEMP °C Two 17 W T8 lamps Two 32 W T8 lamps 40°C 40°C T4 T4 T6 T6 60 60 Eyebolt MAINTENANCE AND RELAMPING (eLLK Series Div. 1/Zone 1 luminaire is shown. Maintenance procedures are the same for the nLLK.) Hexagon Screw 1. One quarter turn with the SW13 hexagon key or a 5⁄16⍯ (M8) Allen hex head wrench releases multiple locking points. 2. Lamps can be stored in open lens, freeing up hands for easy relamping. 3. Replace the bi-pin lamp, lock with one quarter turn of the wrench for an IP65, Type 4X seal. Ceiling Mounting Bracket DIMENSIONS (mm) & WEIGHT Weight: 8.8 lbs. (4.0 kg.)—17 W 13.2 lbs. (6.0 kg.)—32 W Pipe Clamp US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:851)) CH0 5 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 851 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0852-23 Name: 6L-852 6L 100: DATE: JAN 19 2006 Time: 5:57:07 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 CI.I, Div. 2, Groups A,B,C,D Wet Locations CI.I, Zone 2 Group IIC NEMA 3,3R CI.II, Div. 1, Groups F,G CI.III & Simultaneous Presence FVN Series Flourescent Luminaires Certifications and Compliances: NEC and CEC: ɀ Class I, Division 2 Groups A, B, C & D ɀ Class I, Zone 2 Groups IIC ɀ Class II, Division 1 Groups F, G ɀ Class III ɀ Simultaneous Presence (Cl. I and Cl. II) UL Standards: ɀ 844 Hazardous (Classified) Areas ɀ 1598 Luminaires CSA Standards: ɀ C22.2 NO. 137 FVN Luminaires are ideal for use: ɀ In areas made hazardous by the abnormal conditions resulting in the presence of flammable vapors or gases and combustible dusts as defined by the National Electrical Code®. ɀ Where broken lamps would damage machinery or processes, or harm people working in the area. ɀ In areas where stringent sanitation requirements exist. Standard Materials: ɀ Luminaire housing - 20-gauge seamless sheet steel ɀ Lens/Frame Assembly - stainless steel ɀ Glass - 3/16” tempered ɀ Suspension flanges - seamless sheet steel ɀ Gaskets - silicone ɀ Lamphoders - white thermoset plastic ɀ Clamps - stainless steel Features ɀ One-piece seamless sheet steel housing with welded end caps keeps dirt, dust and moisture away from ballast and lamps. Easy to clean. ɀ A silicone rubber gasket provides a dust-tight seal between the lens/frame assembly and housing. ɀ Lens/frame assembly is hinged and wireway cover is held by safety chain for ease of lamp replacement and maintenance. ɀ Polyester powder coat finish provides high reflectance and corrosion resistance for long life and dependable service. ɀ Two 1⁄2” NPT pendant hubs and two 1⁄2” NPT thru-feed end hubs are standard. ɀ Electronic ballast is standard on 32, 40(/UNV only) and 54 watt luminaires. FVN Fluorescent Luminaires with T5 HO lamps offer... ɀ High lumen output per watt - provides energy savings versus other higher wattage fluorescent luminaires with similar lumen output. ɀ Longer lamp life and good lumen maintenance - reduced maintenance and lamp replacement costs. Standard Finishes: ɀ Reflector housings - corrosion resistant white polyester powder coat ɀ Lens/Frame - natural Dimensions: Ordering Information (Lamps not supplied): Supercedes ordering information in Catalog 6000, Section 5L. Lamp Watts 32 32 40 40 60 60 60 60 Line Voltage/Hertz 120-277/50-60 347/60 120-277/50-60 347/60 120/60 277/60 347/60 220/50 Lamp Type T8 T8 T12 T12 T12HO T12HO T12HO T12HO Hub Size 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT FVN Fluorescent Luminaires with T5 HO Lamps (Lamps not supplied) 54 120-277/50-60 T5HO 1/2 NPT 54 347/60 T5HO 1/2 NPT 852 STIBOINFO((CRH:66008com:6L:852)) CH0 5 L - 3 0 US: 1-866-764-5454 CAN: 1-800-265-0502 2-Lamp Cat. No. FVN4232TG/UNV FVN4232TG/347 FVN4240TG/UNV FVN4240TG/347 FVN4260TG/120 FVN4260TG/277 FVN4260TG/347 FVN4260TG/200-50 3-Lamp Cat. No. FVN4332TG/UNV FVN4332TG/347 FVN4340TG/UNV FVN4340TG/347 — — — — FVN4254TG/UNV FVN4254TG/347 — — Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0853-16 Name: 6L-853 100: DATE: JAN 19 2006 Time: 5:57:08 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 CI.I, Div. 2, Groups A,B,C,D Wet Locations CI.I, Zone 2 Group IIC NEMA 3,3R CI.II, Div. 1, Groups F,G CI.III & Simultaneous Presence FVN Series Flourescent Luminaires 6L Options: The following special options are available from the factory by adding suffix to luminaire Cat. No. Description ɀ Low temperature electromagnetic ballast, 40W rated 0°F (-18°C), 60W rated -20°F (-29°C) ɀ 45° angle brackets (field installed) ɀ Adjustable angle brackets (field installed) ɀ Angle bars for chain suspension (field installed) ɀ Individually fused balast (internal) ɀ Emergency lighting battery unit (Class I, Division 2 only). Also available for use with T5 lamps Supplied with charging indicator light and instructions for use with a remote push-to-test station. † Suffix BY AG KH CX FB S799† If push-to-test operator installed in the luminaire is required, consult factory. Temperature Performance Data: (Based on 40°C ambient) Lamp 32W 40W 54W 60W Cl. I, Div. 2 & Zone 2 Supply2-Lamp 3-Lamp T5 T5 T5 T5 T3C — T4 — Class II 2-Lamp T6 T6 T6 T6 3-Lamp T6 T6 — — Simultaneous Presence 2-Lamp 3-Lamp T4 T4 T4 T4 T3C/T6 — T4 — Supply Wire 60°C 60°C 75°C 90°C Photometric Data: Luminaire with two 54W High Output T5 Linear Fluorescent Lamps FVN4254 FVN .ies photometric files for use with our Luxicon® Lighting Layout Software are available from the Resources area of our website. US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:853)) CH0 5 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 853 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0854-3 Name: 6L-854 6L 100: DATE: JAN 19 2006 Time: 5:57:09 PM Operator: RB FVN Series Fluorescent Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Luminaire: FVN with 2-40W lamps (tempered lens) Luminaire: FVN with 3-40W lamps (tempered lens) Lamp: 2-40/T-12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 1182 1971 3555 4284 Total Bare Lamp Lumens: 6300 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. Lamp: 3-40/T-12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 1695 2834 5099 6079 Total Bare Lamp Lumens: 9450 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for 2-lamp 40W RS cool white luminaires with tempered glass. Use 1.37 multiplier for 2-lamp 60W luminaires with tempered glass. Use .92 multiplier for 2-lamp 32W luminaires with tempered glass. Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .721 .643 .575 80 30 .695 .603 .527 10 .673 .569 .489 50 .706 .631 .566 70 30 .683 .594 .520 10 .661 .564 .485 50 .677 .607 .547 50 30 .657 .577 .508 10 .641 .549 .476 50 .650 .586 .528 30 30 .636 .561 .496 10 .621 .538 .468 50 .627 .568 .512 10 30 .614 .544 .484 10 .602 .526 .460 0 0 .589 .512 .447 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .416 .375 .338 80 30 .359 .319 .283 10 .319 .281 .244 50 .409 .370 .333 70 30 .356 .315 .281 10 .316 .278 .244 50 .397 .359 .324 50 30 .350 .309 .277 10 .314 .276 .242 50 .386 .348 .316 30 30 .344 .306 .272 10 .311 .273 .240 50 .376 .341 .308 10 30 .338 .301 .268 10 .308 .271 .239 0 0 .295 .258 .226 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .682 .610 .546 80 30 .658 .572 .501 10 .637 .540 .466 50 .668 .599 .538 70 30 .646 .563 .495 10 .625 .535 .462 50 .640 .576 .520 50 30 .622 .547 .454 10 .606 .521 .433 50 .615 .556 .502 30 30 .601 .532 .472 10 .587 .511 .446 50 .594 .537 .487 10 30 .581 .517 .461 10 .570 .499 .439 0 0 .557 .487 .426 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .396 .357 .322 80 30 .343 .304 .270 10 .305 .268 .234 50 .390 .352 .317 70 30 .340 .301 .268 10 .302 .266 .233 50 .378 .342 .309 50 30 .334 .295 .264 10 .300 .264 .231 50 .368 .332 .301 30 30 .328 .292 .259 10 .298 .261 .230 50 .358 .325 .294 10 30 .322 .288 .256 10 .294 .259 .228 0 0 .283 .247 .217 854 STIBOINFO((CRH:66008com:6L:854)) CH0 0 5 L - 7 NOTE: All data provided is for 2-lamp 40W RS cool white luminaires with tempered glass. Use 1.37 multiplier for 2-lamp 60W luminaires with tempered glass. Use .92 multiplier for 2-lamp 32W luminaires with tempered glass. 4 .513 .459 .418 .505 .455 .415 .488 .444 .410 .473 .435 .405 .459 .426 .399 .385 5 .461 .404 .362 .452 .399 .359 .439 .392 .357 .426 .384 .353 .414 .378 .349 .336 9 .309 .254 .217 .305 .252 .217 .297 .249 .215 .289 .244 .214 .282 .242 .212 .200 10 .269 .215 .180 .265 .215 .180 .259 .211 .179 .253 .208 .177 .247 .205 .175 .164 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 4 .488 .438 .399 .480 .433 .396 .464 .423 .391 .450 .415 .386 .437 .406 .381 .368 5 .439 .385 .346 .430 .381 .343 .418 .374 .341 .406 .367 .337 .394 .361 .333 .321 9 .294 .242 .207 .290 .240 .207 .282 .237 .206 .276 .233 .204 .269 .231 .202 .192 10 .256 .205 .172 .252 .205 .172 .247 .201 .171 .241 .199 .169 .235 .196 .168 .157 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0855-27 Name: 6L-855 100: DATE: JAN 19 2006 eLLB20 Series Recessed Mount Fluorescent Luminaires Time: 5:57:10 PM Operator: RB Class I, Div.2, Groups A,B,C,D Class I, Zone 1, Groups IIC ATEX Certified COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. II, Div 2, Groups F,G Cl. II, Div 1, Groups E,F,G (Canada) Wet Locations Enclosure Type 4X and IP66 Features & Benefits: Applications: ɀ One piece welded housing with fitted cover frame. The cover frame is an integral part of the housing to seal out dust & moisture. ɀ Adjustable mounting clamps: - permanently attached and adjustable through the cover frame for easy installation. - allow recess mounting in ceilings from 25mm to 100mm (1⍯ to 4⍯ approx) thick for maximum mounting flexibility. ɀ Support lugs (M8 x .6) to secure the luminaire to ceiling structural support members for safety. ɀ Frameless tempered glass lens: - 6mm (1⁄4⍯) thick for added safety. - interior hinge for maximum dust shedding. - fitted with captive screws for ease of lamp replacement and maintenance. ɀ Isolating switch turns off power to the ballast and lamps when the lens is opened for added safety. ɀ 4 entries (2 on each end) supplied with (2) 3⁄4” NPT adapter hubs and extra large wire well for feedthrough and tandem applications without the need for separate junction boxes. ɀ Electronic ballast: - high power factor (95%) for energy efficiency, more luminaires per circuit and supply voltage flexibility. - features 2 channel circuitry for safety - if one lamp fails the 2nd lamp remains in operation. ɀ Uses T8 linear fluorescent lamps for high efficiency and reduced operating costs. ɀ 5 wire terminal block and through wiring are standard for quick and easy balancing of lighting loads on 3 phase systems. eLLB series luminaires are used: ɀ For flush or surface ceiling mounting. ɀ In cleanroom areas where it is important to have smooth, flush surfaces. ɀ Where extreme cleanliness is required as in pharmaceutical, chemical and electronics manufacturing facilities, as well as in paint shops and spray booths. ɀ For tough environmental conditions involving corrosives, water, dust and extreme temperatures. ɀ In areas that require lamps to reach full illumination immediately. ɀ Indoor & outdoor ordinary or hazardous areas. ɀ For Wet locations and areas with hose down / wash down requirements. Adjustable Mounting Clamps Hinged Glass Lens 6L Certifications & Compliances: NEC : ɀ Class I, Division 2, Groups A,B,C,D ɀ Class I, Zone 1 AEx ed IIC ɀ Class II, Division 2, Groups F, G ɀ UL Listed CEC: ɀ Class I, Division 2, Groups A,B,C,D ɀ Class I, Zone 1 Ex eds IIC ɀ Class II, Division 1 Groups E,F,G ɀ cUL Listed Enclosure ɀ Type 4X ɀ IP66 UL Standards ɀ 2279 Hazardous (Classified) Locations ɀ 1598 Luminaires CSA Standards ɀ C22.2 No. 9 ɀ CAN/CSA-E60079-0:02 ɀ CAN/CSA-E60079-1:02 ɀ CAN/CSA-E60079-7 ɀ CAN/CSA-E61241-1-1:02 ATEX ɀ ATEX Directive 94/9/EC ɀ Type of Protection ɀ EC-Type Examination Certificate II 2 G II 2 D T80°C EEx ed IIC T4 EEx ed ib IIC T4 (CG-variant) DMT 02 ATEX E 069 Standard Materials: ɀ One piece welded housing and cover frame - sheet steel or stainless steel ɀ Lens - 6mm (1/4⍯) thick tempered glass ɀ Gaskets - Silicone ɀ External hardware - stainless steel Standard Finishes: ɀ Sheet steel - White epoxy coat ɀ Lens - Clear ɀ Stainless steel - Natural US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:855)) CH0 5 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 855 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0856-30 Name: 6L-856 100: DATE: JAN 19 2006 COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Class I, Div.2, Groups A,B,C,D Cl. II, Div 2, Groups F,G Class I, Zone 1, Groups IIC Cl. II, Div 1, Groups E,F,G (Canada) ATEX Certified Wet Locations Enclosure Type 4X and IP66 eLLB20 Series 6L Time: 5:57:13 PM Operator: RB Recessed Mount Fluorescent Luminaires Ratings (Electrical / Size): Temperature Performance Data: Sources/Wattages ɀ Two 32W or 17W T8 Linear Fluorescent Voltages ɀ 120-240V, 50-60 Hz. ɀ 110-230VDC Hub Size ɀ Four 25mm entries, 2 on each end, 3 plugged. ɀ Two 3⁄4” NPT adapter hubs provided standard, for feed-through or tandem wiring. Terminals ɀ 5 wire terminal block, one on each end (L1, L2, L3, N, Ground) ɀ Two 6mm2 (#10 AWG) maximum per terminal Minimum Starting Temperature: -20°C Watts Two 17W T8 lamps Two 32W T8 lamps Ambient Temp. 50°C 50°C Cl. I, Div. 2 Cl. I, Zone 1 & 2 T4 T4 Class II T6 T6 Supply Wire Temp 60°C 60°C Accessories: ɀ 3⁄4⍯ NPT adapter hub STM2 Mounting Accessories: ɀ Eye Bolt for Support Lugs ɀ Hexagon Screw for Support Lugs 2 2480 002 000 2 2480 054 000 Ordering Information: Hub Size Wattage/Lamp 3⁄4⍯ NPT Two 17 Watt T8 Rapid Start 3⁄4⍯ NPT Two 32 Watt T8 Rapid Start Voltage/Hz 120-240V, 50-60 Hz 110-230 VDC 120-240V, 50-60 Hz 110-230 VDC Operating Current Catalog Number Epoxy Coated Stainless Steel Steel Enclosure Enclosure .18A eLLB20 2217/U240 eLLB20 2217SS/U240 .34A eLLB20 4232/U240 eLLB20 4232SS/U240 IEC / CENELEC certified luminaires are available. Consult factory. Dimensions (Inches) and Weights: Item eLLB20 2217 eLLB20 4232 856 STIBOINFO((CRH:66008com:6L:856)) CH0 5 L - 3 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Weight 33 lbs. 48 lbs. Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0857-24 Name: 6L-857 DATE: JAN 19 2006 Time: 5:57:14 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data eLLB20 Series Recessed Mount Fluorescent Luminaires 6L Photometric Data: COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 20% ROOM CAVITY RATIO EFF. CEIL. 80° 70° 50° 30° 10° 0° WALL 1 2 3 4 5 6 7 8 9 10 50° 0.679 0.597 0.528 0.468 0.412 0.368 0.329 0.294 0.263 0.239 30° 0.654 0.556 0.478 0.414 0.355 0.310 0.272 0.239 0.209 0.186 10° 0.631 0.522 0.439 0.372 0.313 0.269 0.233 0.200 0.172 0.151 50° 0.664 0.585 0.518 0.459 0.405 0.632 0.324 0.290 0.259 0.235 30° 0.641 0.547 0.472 0.409 0.351 0.307 0.270 0.237 0.207 0.185 10° 0.621 0.516 0.435 0.369 0.311 0.268 0.232 0.200 0.172 0.151 50° 0.637 0.562 0.499 0.443 0.391 0.350 0.314 0.281 0.252 0.229 30° 0.618 0.531 0.460 0.399 0.344 0.302 0.265 0.233 0.204 0.182 10° 0.601 0.504 0.427 0.364 0.308 0.266 0.230 0.198 0.171 0.150 50° 0.612 0.542 0.482 0.429 0.379 0.339 0.305 0.273 0.245 0.223 30° 0.597 0.515 0.448 0.390 0.337 0.296 0.261 0.229 0.201 0.180 10° 0.583 0.492 0.420 0.360 0.304 0.263 0.228 0.197 0.170 0.149 50° 0.589 0.522 0.465 0.415 0.367 0.329 0.296 0.265 0.238 0.217 30° 0.577 0.501 0.437 0.382 0.330 0.291 0.257 0.226 0.198 0.177 10° 0.566 0.481 0.413 0.355 0.301 0.261 0.257 0.196 0.169 0.149 0° 0.553 0.468 0.400 0.341 0.288 0.248 0.214 0.183 0.156 0.137 * PERCENT REFLECTANCE US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:857)) CH0 5 L - 3 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 857 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0858-7 Name: 6L-858 6L 100: DATE: JAN 19 2006 Time: 5:57:15 PM Operator: RB COLOR: CMYK ɀ ɀ ɀ ɀ Cl. I, Div 1, Groups C,D Cl. I, Zone 1 Group IIB ɀ Cl. II, Div 1, Groups E,F,G ɀ Cl. III, Simultaneous Presence EVF Series Fluorescent Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 Paint Spray (Suffix S718) Wet Locations (Suffix S718) ɀ 3,3R, IP54 (Suffix S718) Application: EVF luminaires are used in areas where hazardous fumes, gases, or dusts are present. EVF luminaires with S718 option are designed specifically for use inside paint spray booths where hazardous fumes, gases, and paint residue are present. This includes powder paint process areas. EVF luminaires with S718 option are also suitable for use in wet locations. Features: All EVF luminaires ɀ Provide cool, even light with natural color rendition ɀ Reduce relamping schedule (long lamp life) ɀ Continuous and uniform illumination made possible by mounting end to end (no space needed between luminaires for relamping) ɀ No special tools required for relamping. Threaded lamp tube cover provides quick and easy access for relamping ɀ Threaded joints on lamp tube and wiring chamber covers permit easy access for lower maintenance costs ɀ Reflectors can be removed or replaced with only a screwdriver ɀ Easy to install. Factory sealed and wired luminaire facilitates installation ɀ Standard electronic ballast for 32 watt and 40 watt rapid start luminaires. ɀ Standard energy efficient ballast for 40 watt slimline, 60 watt and 110 watt luminaires. ɀ Low temperature ballast is supplied as standard on 32 watt T8 (0°F), 40 watt slimline (0°F); 60 watt and 110 watt luminaires(–20°F). ɀ All exposed hardware is stainless steel for maximum protection against corrosion, and for longer luminaire life ɀ Copper-free aluminum construction throughout means lighter luminaire weight, easier installation, and excellent corrosion resistance ɀ All exterior materials are nonsparking ɀ Type P ballasts furnished in compliance with NEC ɀ Heavy-duty glass lamp tubes provide maximum strength and impact resistance to protect lamps 858 STIBOINFO((CRH:66008com:6L:858)) CH0 5 L - 2 1 3-lamp 2-lamp with angle reflector EVF Furnished For Hub Line Volts 1-Lamp 2-Lamp 3-Lamp 4-Lamp Use With Size 60 Hz.* Cat. # Cat. # Cat. # Cat. # 3⁄4⍯ 32 watt, T-8 medium 120-277 EVF21029/UNV EVF22029/UNV EVF23029/UNV EVF24029/UNV 3⁄4⍯ 347 EVF21029/347 EVF22029/347 EVF23029/347 EVF24029/347 Bi-pin 265MA lamps 40 watt, T-12 medium 3/4⍯ 110-125 EVF21082 EVF22082 EVF23082 EVF24082 Bi-pin rapid start 3/4⍯ 277 EVF21087 EVF22087 EVF23087 EVF24087 430MA lamps† 3/4⍯ 347 EVF21089/347 EVF22089/347 EVF23089/347 EVF24089/347 3⁄4⍯ 110-125 EVF21032 EVF22032 EVF23032 EVF24032 40 watt, T-12 single 3⁄4⍯ 277 EVF21037 EVF22037 EVF23037 EVF24037 pin, slimline 3⁄4⍯ 347 EVF21039/347 EVF22039/347 EVF23039/347 EVF24039/347 425MA lamps EVF21062 EVF22062 EVF23062 EVF24062 60 watt, T-12 recessed 3⁄4⍯ 110-125 EVF21067 EVF22067 EVF23067 EVF24067 contact, 800MA lamps† 3⁄4⍯ 277 3⁄4⍯ 347 EVF21069/347 EVF22069/347 EVF23069/347 EVF24069/347 EVF21072 EVF22072 EVF23072 EVF24072 110 watt, T-12 recessed 3⁄4⍯ 110-125 EVF21077 EVF22077 EVF23077 EVF24077 contact, 1500MA lamps† 3⁄4⍯ 277 3⁄4⍯ 347 EVF21079/347 EVF22079/347 EVF23079/347 EVF24079/347 * For 220 volt 50 hz, 240 volt 50 hz or 240 volt 60 hz operation change the last ‘‘2’’ in the 120 volt 60 hz catalog number to a ‘‘9’’ and add ‘‘/220 50’’, ‘‘/240 50’’ or ’’/240 60’’ respectively. ie. For a 2 lamp, 40 watt rapid start luminaire for 220 volt 50 hz operation order an EVF22089/220 50. † 50 Hz not available. EVF luminaires with S718 option ɀ All joints sealed ɀ Inside paint booth mounting capabilities provide greater flexibility in luminaire placement, avoids necessity of complicated design and installation work, and improves task lighting control ɀ Smooth simple design makes it easy to remove any accumulated deposits of paint residue Mounting Accessories: Various hazardous area fittings are used to mount EVF luminaires. The fittings shown on page 859 support the unwired (relamping) end. For the wired (ballast) end any of the luminaire hangers for hazardous locations (listed in Section 7L) can be used. CPS conduit outlet bodies with hub covers (listed in Section 4F) are also suitable Standard Materials: Options: ɀ For suitability for wet locations and locations having deposits of readily combustible paint residue – add Cat. No. Suffix S718 ɀ Corro-free TM epoxy powder coat – add Cat. No. Suffix S752 ɀ With 45° angle reflectors in lieu of straight down reflectors – add Cat. No. Suffix S369 ɀ Clear disposable polyester tube wrap – consult Cooper Crouse-Hinds ɀ Fused – add suffix S658‡ ɀ Furnished with lamps - add suffix S714. ɀ Low temperature electromagnetic ballast for 40 watt T12 rapid start luminaires rated for 0°F - add suffix BY. Size Ranges: ɀ 1, 2, 3, and 4-lamp Electrical Rating Ranges: ɀ Copper-free aluminum except sheet aluminum reflectors Standard Finishes: ɀ Natural except reflectors ɀ Reflectors – white epoxy powder coat Certifications and Compliances: ɀ NEC and CEC: Class I, Division 1 Group C, D Class I, Zone 1 Group IIB Class II Group E, F, G Class III Simultaneous Presence (Cl. I and Cl. II) Paint Spray (S718) ɀ UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires ɀ CSA Standards: C22.2 No. 137 ɀ 32 to 110 watts Temperature Performance Data: (Based on 40°C Ambient) Lamp Type 32/40W 60W 110W 1 Lamp T5 T5 T4 US: 1-866-764-5454 Class I/Class II/Zone 1 2 Lamp 3 Lamp 4 Lamp T5 T5 T5 T5 T5 T5 T4 T4 T4 CAN: 1-800-265-0502 Supply Wire 75°C 75°C 90°C Copyright© 2006 Cooper Crouse-Hinds ‡ When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0859-2 Name: 6L-859 100: DATE: JAN 19 2006 Time: 5:57:17 PM Operator: TB Size 3⁄4 TCP: 15001 Typedriver Name: TS name csm no.: 100 Accessories Relamping Information EVF Series Fluorescent Luminaires Ceiling Saddle for Conduit Support COLOR: CMYK 6L Relamping Information Cat. # EVF20 Ceiling Saddle for Support Hook Adjacent ends of two fixtures suspended in line close together Cat. # EVF021 One cover removed and lamp partly withdrawn Where fixtures abut, space for relamping is obtained by lowering one end of the tube assembly as shown. Without tools, the lamp receptacle and mounting plate assemblies can be removed and the lamp withdrawn. In inserting, the reverse procedure is followed. Support Hook for Conduit Size 3⁄4 Cat. # EVF21 End of one fixture lowered for relamping Dimensions End view Fixture Type 32 watt, T-8 Bi-pin 40 watt, T-12 Bi-pin 40 watt, T-12 Single pin slimline 60 watt, T-12 Recessed contact 110 watt, T-12 Recessed contact No. Lamps ⎫ ⎭ 1 or 2 3 or 4 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:859)) CH0 5 L - 2 2 a 44 461⁄2 b 11 81⁄2 c d 533⁄8 533⁄8 CAN: 1-800-265-0502 55 55 e 95 100 f 101⁄4 101⁄4 Copyright© 2006 Cooper Crouse-Hinds 1-Lamp 2-Lamp 3-Lamp 4-Lamp Width 61⁄8 111⁄2 18 241⁄2 859 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: JOB: CRMAIN06-0860-3 Name: 6L-860 6L 100: DATE: JAN 19 2006 Time: 5:57:18 PM Operator: RB EVF Series Fluorescent Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Luminaire: All 1-Lamp EVF Luminaires Luminaire: All 2-Lamp EVF Luminaires Lamp: 1-40/T-12, 1-60/T-12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 580 953 1633 1897 Total Bare Lamp Lumens: 3100 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. Lamp: 2-40/T-12, 2-38/T-12, 2-60/T-12, 2-110/T12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 1055 1765 3262 4125 Total Bare Lamp Lumens: 6300 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for 40W rapid start cool white lamps. Use following candlepower/lumen multipliers for other lamp sizes: 32W 0.90 40W Slimline 0.84 60W Cool white 1.29 110W Cool white 2.19 NOTE: All data provided is for 40W rapid start cool white lamps. Use following candlepower/lumen multipliers for other lamp sizes: 32W 0.90 40W Slimline 0.84 60W Cool white 1.29 110W Cool white 2.19 Example: Zonal lumens of 1-40W lamp for 0-60° is 1633. Zonal lumens of 1-60W lamp for 0-60° is 1633 × 1.29 ⍧ 2107 Example: Zonal lumens of 2-40W lamp for 0-60° is 3262. Zonal lumens of 2-60W lamps for 0-60° is 3262 × 1.29 ⍧ 4208 Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .697 .616 .546 80 30 .670 .574 .497 10 .647 .539 .458 50 .682 .604 .538 70 30 .658 .565 .490 10 .635 .534 .454 50 .653 .580 .518 50 30 .633 .549 .478 10 .616 .520 .446 50 .627 .559 .500 30 30 .612 .533 .467 10 .597 .509 .438 50 .605 .539 .484 10 30 .591 .517 .455 10 .579 .498 .431 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .391 .351 .316 80 30 .334 .295 .262 10 .294 .257 .223 50 .384 .346 .312 70 30 .330 .292 .260 10 .290 .255 .222 50 .372 .336 .303 50 30 .324 .286 .255 10 .288 .252 .221 50 .361 .325 .295 30 30 .319 .283 .251 10 .286 .249 .219 50 .351 .318 .287 10 30 .312 .278 .247 10 .283 .248 .218 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .697 .616 .546 80 30 .670 .574 .497 10 .647 .539 .458 50 .682 .604 .538 70 30 .658 .565 .490 10 .635 .534 .454 50 .653 .580 .518 50 30 .633 .549 .478 10 .616 .520 .446 50 .627 .559 .500 30 30 .612 .533 .467 10 .597 .509 .438 50 .605 .539 .484 10 30 .591 .517 .455 10 .579 .498 .431 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .391 .351 .316 80 30 .334 .295 .262 10 .294 .257 .223 50 .384 .346 .312 70 30 .330 .292 .260 10 .290 .255 .222 50 .372 .336 .303 50 30 .324 .286 .255 10 .288 .252 .221 50 .361 .325 .295 30 30 .319 .283 .251 10 .286 .249 .219 50 .351 .318 .287 10 30 .312 .278 .247 10 .283 .248 .218 860 STIBOINFO((CRH:66008com:6L:860)) CH0 5 L - 2 3 98: 4 .485 .430 .388 .477 .426 .385 .460 .416 .380 .445 .407 .375 .431 .397 .370 5 .434 .376 .334 .425 .372 .331 .412 .365 .329 .399 .357 .325 .388 .351 .321 9 .289 .235 .197 .285 .233 .197 .277 .229 .196 .270 .225 .194 .263 .222 .193 10 .252 .198 .164 .248 .198 .164 .242 .195 .162 .236 .192 .161 .230 .189 .159 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 4 .485 .430 .388 .477 .426 .385 .460 .416 .380 .445 .407 .375 .431 .397 .370 5 .434 .376 .334 .425 .372 .331 .412 .365 .329 .399 .357 .325 .388 .351 .321 9 .289 .235 .197 .285 .233 .197 .277 .229 .196 .270 .225 .194 .263 .222 .193 10 .252 .198 .164 .248 .198 .164 .242 .195 .162 .236 .192 .161 .230 .189 .159 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0861-3 Name: 6L-861 100: DATE: JAN 19 2006 Time: 5:57:19 PM Operator: RB TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data EVF Series Fluorescent Luminaires 6L Luminaire: All 3-Lamp EVF Luminaires Luminaire: All 4-Lamp EVF Luminaires Lamp: 3-40/T-12, 3-38/T-12, 3-60/T-12, 3-110/T-12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 1917 3226 6066 7919 Total Bare Lamp Lumens: 9300 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. Lamp: 4-40/T-12, 4-38/T-12, 4-60/T-12, 4-110/T-12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 1961 3305 6250 8224 Total Bare Lamp Lumens: 12400 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for 40W rapid start cool white lamps. Use following candlepower/lumen multipliers for other lamp sizes: 32W 0.90 40W Slimline 0.84 60W Cool white 1.29 110W Cool white 2.19 NOTE: All data provided is for 40W rapid start cool white lamps. Use following candlepower/lumen multipliers for other lamp sizes: 32W 0.90 40W Slimline 0.84 60W Cool white 1.29 110W Cool white 2.19 Example: Zonal lumens of 3-40W lamps for 0-40° is 3226. Zonal lumens of 3-40W Slimline lamps for 0-40° is 3226 × 0.84 ⍧ 2710 Example: Zonal lumens of 4-40W lamps for 0-30° is 1961. Zonal lumens of 4-110W lamps for 0-30° is 1961 × 2.19 ⍧ 4295 Coefficient of Utilization Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .712 .626 .553 80 30 .683 .581 .500 10 .658 .544 .459 50 .697 .614 .544 70 30 .670 .572 .494 10 .646 .539 .455 50 .667 .589 .524 50 30 .645 .555 .481 10 .626 .524 .446 50 .640 .567 .505 30 30 .623 .539 .469 10 .607 .513 .439 50 .617 .547 .488 10 30 .602 .523 .457 10 .589 .502 .431 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .392 .352 .317 80 30 .332 .293 .260 10 .290 .254 .219 50 .385 .347 .312 70 30 .329 .290 .258 10 .287 .251 .218 50 .372 .336 .303 50 30 .322 .284 .253 10 .285 .248 .217 50 .362 .325 .295 30 30 .317 .280 .248 10 .282 .245 .215 50 .351 .317 .286 10 30 .310 .276 .244 10 .279 .244 .214 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .692 .607 .535 80 30 .664 .563 .484 10 .639 .526 .442 50 .678 .595 .526 70 30 .652 .554 .477 10 .628 .521 .439 50 .648 .571 .507 50 30 .627 .538 .465 10 .609 .507 .431 50 .622 .550 .488 30 30 .606 .522 .453 10 .590 .497 .423 50 .600 .530 .472 10 30 .585 .506 .442 10 .572 .486 .416 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .379 .340 .306 80 30 .320 .282 .250 10 .278 .243 .210 50 .372 .335 .301 70 30 .316 .279 .248 10 .275 .240 .209 50 .359 .324 .292 50 30 .310 .273 .243 10 .273 .238 .208 50 .349 .313 .284 30 30 .305 .269 .238 10 .271 .235 .206 50 .339 .306 .276 10 30 .298 .265 .235 10 .268 .234 .205 4 .489 .431 .386 .481 .426 .383 .463 .416 .378 .447 .407 .374 .433 .397 .368 5 .436 .376 .331 .427 .371 .328 .414 .364 .326 .400 .356 .322 .388 .350 .318 9 .289 .233 .194 .285 .230 .194 .277 .227 .192 .269 .223 .191 .262 .220 .189 10 .252 .196 .160 .248 .196 .160 .242 .193 .159 .236 .190 .157 .230 .187 .156 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:861)) CH0 5 L - 2 4 COLOR: CMYK CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 4 .473 .416 .372 .465 .411 .369 .447 .401 .364 .432 .392 .360 .418 .383 .354 5 .421 .362 .318 .412 .357 .315 .399 .351 .313 .386 .343 .309 .374 .337 .305 9 .279 .224 .185 .275 .221 .185 .267 .218 .184 .260 .214 .183 .253 .211 .181 10 .243 .189 .153 .239 .189 .153 .233 .185 .152 .227 .182 .150 .221 .179 .149 861 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0862-5 Name: 6L-862 6L 100: DATE: JAN 19 2006 Time: 5:57:20 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ ɀ Marine & Wet Cl. I, Div. 1, Groups C,D Cl. I, Zone 1 Group IIB Locations ɀ Cl. II, Div 1, Groups E,F,G ɀ 3,3R,4,4X: IP66 ɀ Cl. III, Simultaneous Presence EVFDR Series Fluorescent Luminaires ɀ Applications: ɀ EVFDR luminaires are suitable for wet locations and marine environments, above and below deck, where hazardous vapors, gases or dusts are present ɀ Ideally suited for use on offshore drilling/ production platforms and on shipboard in hazardous areas ɀ For mounting where headroom is limited ɀ For hazardous areas where watertightness and corrosion resistance are required Features: ɀ Exterior surfaces finished with gray epoxy enamel for corrosion resistance ɀ Exterior hardware stainless steel ɀ All joints sealed and gasketed for watertightness ɀ Vibration resistant -shock mounts -sockets are spring loaded for tight lamp contact connection ɀ Heavy duty glass lamp tubes for maximum strength and impact resistance ɀ All exterior materials are non-sparking ɀ C-type beam clamps provide quick and easy mounting ɀ Luminaire is adjustable 30° either side of fixture axis, allowing for control of light output ɀ Beam clamp support is adjustable allowing beam clamp to be located to suit structure ɀ Low profile – luminaire height is 713⁄16⍯ with standard mounting, 1111⁄16⍯ with shock mounting option – for maximum clearance where headroom is critical ɀ Provides cool light with natural color rendition ɀ Continuous and uniform illumination made possible by mounting end to end (no space needed between luminaires for relamping) – see page 859 for relamping information ɀ Relamping is accomplished without tools. Quarter-turn fastener allows end of luminaire to be lowered quickly. Cable supports end of luminaire while relamping – both hands are free. Threaded lamp tube cover provides quick and easy access to lamp and receptacle ɀ Reflectors can be removed or replaced with only a screwdriver ɀ Ballast housing readily accessible ɀ Minimum weight – copper-free aluminum construction throughout ɀ Type P ballast furnished in compliance with NEC ɀ Standard electronic ballast for 32 watt and 40 watt rapid start. ɀ Standard energy efficient electromagnetic ballast (40W slimline, 60W and 110W) is standard. ɀ Low temperature ballasts are standard on 32WT8, 40W slimline, 60W and 110W. 32 watt and 40 watt low temperature ballasts are rated for 0°F. 60 and 100 watt low temperature ballasts are rated for –20°F. Standard Materials: ɀ Housing – copper-free aluminum ɀ Exposed hardware – stainless steel 862 STIBOINFO((CRH:66008com:6L:862)) CH0 5 L - 2 5 Options: ɀ Furnished with lamps – add suffix S714 to Cat. No. ɀ Furnished with safety cable for high vibration areas - add suffix S715 to Cat. No. ɀ Beam clamps with shock mounts are available for ease of installation and resistance to vibration – add suffix KIT40 to Cat. No. ɀ Beam clamps only – add suffix KIT41 to Cat. No. ɀ Low Temperature Electromagnetic Ballast: 40W rapid start rated 0°F - add suffix BY to Cat. No. ɀ Emergency lighting battery unit – add suffix S799 to Cat. No. Size Ranges: Certifications and Compliances: ɀ NEC and CEC: Class I, Division 1 Group C,D Class I, Zone 1 Group IIB Class II Groups E,F,G Class III Simultaneous Presence (Cl. and Cl. II) ɀ UL Standards 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards C22.2 No. 137 Temperature Performance Data: (Based on 40°C Ambient) ɀ 2-lamp only Electrical Rating Ranges: ɀ 32, 40, 60 and 110W 2-Lamp 32, 40W 60W 110W Class I Class II Zone 1 T5 T5 T4 Supply Wire 75°C 75°C 90°C EVFDR Furnished For Use With 32 watt, T-8 medium Bi-pin 265MA lamps 40 watt, T-12 medium Bi-pin rapid start 430MA lamps† 60 watt, T-12 recessed contact, 800MA lamps 110 watt, T-12 recessed contact, 1500MA lamps† Hub Size 3⁄4⍯ 3⁄4⍯ 3/4⍯ 3/4 3/4⍯ 3/4⍯ 3/4⍯ 3/4⍯ Line Volts 60 Hz.* 120-277 347 110-125 277 2-Lamp Cat. # EVFDR22029/UNV EVFDR22029/347 EVFDR22082 EVFDR22087 110-125 277 110-125 277 EVFDR22062 EVFDR22067 EVFDR22072 EVFDR22077 * For 220 volt 50 hz, 240 volt 50 hz or 240 volt 60 hz operation change the last ‘‘2’’ in the 120 volt 60 hz catalog number to a ‘‘9’’ and add ‘‘/220 50’’, ‘‘/240 50’’ or ‘‘/240 60’’ respectively. ie. For a 2 lamp, 40 watt rapid start fixture for 220 volt 50 hz operation order an EVFDR22089/220 50. † 50 Hz. not available. Standard Finishes: ɀ All exterior metal components – gray epoxy enamel ɀ Reflectors – white epoxy powder coat US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0863-3 Name: 6L-863 100: DATE: JAN 19 2006 Time: 5:57:21 PM Operator: RB COLOR: CMYK TCP: 15001 Photometric Data and Dimensions EVFDR Series Fluorescent Luminaires Typedriver Name: TS name csm no.: 100 6L Dimensions Luminaire: All EVFDR Luminaires Lamp: 2-40/T-12, 2-60/T-12, 2-110/T-12 Zonal Degrees: 0-30 0-40 0-60 0-90 Zonal Lumens: 1416 2352 4263 5863 Total Bare Lamp Lumens: 8600 To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for two 60 watt, T-12 recessed contact 800MA cool white lamps (EVFDR22062). For other wattages use the following conversion factors: 32W .67 40W, Rapid Start .73 40W, Slimline .70 110W, Cool White 1.60 Coefficient of Utilization Example: Zonal lumens for EVFDR226 fixture, across the axis, for 40-50° is 1,060. Zonal lumens for EVFDR223 fixture, across the axis, is 40-50° is: 1,060 × .70 ⍧ 742 Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 3 50 .735 .645 .570 80 30 .700 .594 .512 10 .670 .551 .466 50 .714 .627 .557 70 30 .682 .580 .501 10 .653 .542 .458 50 .673 .593 .528 50 30 .647 .554 .482 10 .624 .520 .444 50 .636 .562 .501 30 30 .616 .530 .463 10 .596 .502 .430 50 .603 .533 .477 10 30 .585 .507 .444 10 .570 .483 .416 0 0 .551 .465 .399 % Reflectance Room Cavity Ratio Eff. Ceil. Wall 6 7 8 50 .408 .368 .332 80 30 .344 .305 .271 10 .298 .262 .228 50 .398 .360 .325 70 30 .338 .299 .267 10 .293 .258 .226 50 .380 .344 .311 50 30 .327 .289 .259 10 .287 .252 .221 50 .364 .328 .299 30 30 .317 .282 .251 10 .281 .246 .217 50 .348 .316 .286 10 30 .306 .274 .244 10 .274 .241 .213 0 0 .259 .226 .198 4 .506 .442 .394 .494 .435 .388 .468 .418 .378 .446 .403 .368 .425 .388 .358 .340 5 .452 .387 .339 .440 .380 .334 .420 .368 .327 .401 .354 .319 .383 .343 .311 .294 9 .304 .243 .202 .297 .240 .201 .285 .233 .197 .274 .226 .193 .263 .220 .189 .175 10 .266 .207 .169 .260 .206 .168 .250 .199 .164 .240 .193 .160 .231 .188 .157 .144 US: 1-866-764-5454 STIBOINFO((CRH:66008com:6L:863)) CH0 5 L - 2 6 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 863 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0864-1 Name: Note Page-864 DATE: JAN 19 2006 Time: 5:57:22 PM Operator: JB COLOR: CMYK Notes Page 864 STIBOINFO((CRH:66008com::864)) CH0 3 A - 1 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0865-5 Name: 7L-865 100: DATE: JAN 19 2006 Time: 5:57:23 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous 7L Description Page No. Application/Selection 866 Floodlights Luminaires Champ-Pak® CPMV 867-873 H.I.D. Voyager nR TM Stainless Steel Series F2MV Champ® Series FMV Champ® Series FMV High Wattage Champ® Series EVMA S812 Hazard ȿ Gard with Trunnion Arm FZD Series 874-876 877-879 880-882 883-885 890 887-889 Incandescent RCDE Series US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:865)) CH0 0 0 0 7 L CAN: 1-800-265-0502 891, 892 Copyright© 2006 Cooper Crouse-Hinds 865 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0866-4 Name: 7L-866 7L DATE: JAN 19 2006 Time: 5:57:23 PM Operator: RB Application: Table 500-3(d) Identification Numbers. Maximum Temperature Deg. C Deg. F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185 Identification Number T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 TCP: 15001 Typedriver Name: TS name csm no.: 100 Application and Selection Quick Selector Chart Champ-Pak TM Wall Pack & Floodlight Luminaires ɀ General illumination of hazardous and non-hazardous areas COLOR: CMYK Considerations for Selection: Environmental: ɀ What is the hazardous area classification (NEC ®/CEC) of the location in which the luminaires will be installed? Lighting levels required: ɀ What wattage luminaire(s) will provide the desired light levels? See Lighting Selector Guide, pages 665 to 689, to determine number and location of luminaires required. Physical arrangement: ɀ Type of luminaire mounting required, threaded hub or mounting feet. Quick Selector Chart Luminaire NEC Hazardous Area Compliance Lamp Size (Watts) Lamp Base CPMV Cl. I, Division 2 50-150 HID Mogul EVMA-S812 Cl. I, Groups C, D Cl. I, Groups B (suffix GB), C & D 50–400 HID Mogul Cl. I, Division 2 Cl. I, Zone 2 150-400 HID Mogul F2MV, FMV, FMV High Wattage Cl. I, Division 2 70-1500 HID Mogul FZD Cl. I, Division 1 Groups B, C, D 150-400 HID Mogul RCDE-6 Cl. I, Groups C, D Cl. I, Group D 150 Incandescent 300 Incandescent Medium RCDE-10 Cl. I, Group D 500 Incandescent Extended Mogul End Prong VOYAGER nR (SSFMV) 866 STIBOINFO((CRH:66008com:7L:866)) CH0 0 7 L - 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0867-14 Name: 7L-867 100: DATE: JAN 19 2006 Champ-Pak TM Wall Pack Luminaires Time: 5:57:24 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 2, Groups A,B,C,D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups F & G Cl. III & Simultaneous Presence Marine & Wet Locations ɀ Enclosure Type 4X, IP66 7L The first low-profile wall pack designed specifically for hazardous areas. The Cooper Crouse-Hinds® Champ-Pak TM wall pack luminaire is ideal for low-profile mounting in hazardous and industrial environments. In fact, it is suitable for any area with adverse conditions such as dust, dirt, moisture, vibration, high-pressure hosedowns and high thermal ambients. Its precisely designed glass refractor minimizes fixture depth while providing uniform, glare-free illumination. ɀ Unique compact shallow-profile design mounts virtually anywhere. ɀ Side-hinged cover with two-screw closing for easy installation and maintenance. ɀ Gray Corro-free TM epoxy powder-coated two-piece housing provides superior corrosion resistance. ɀ Unique stainless steel wire guard accessory attaches without any additional hardware for easy installation and maintenance. ɀ Glass refractor provides uniform light distribution to eliminate glare. ɀ Vertical lamp design provides even lamp heat distribution for cooler operation, providing expanded hazardous area suitability. ɀ Silicone gaskets make luminaire suitable for enclosure Type 4X, Marine and IP66 environments. ɀ Available in two different conduit entry configurations to permit flexible installation and mounting. ɀ four 3⁄4⍯ NPT hubs, one on each side ɀ two 1⁄2⍯ NPT hubs on bottom for feed-through applications APPLICATIONS ADDITIONAL FEATURES & BENEFITS ɀ indoor and outdoor wall mounting or vertical surface mounting where minimal fixture depth is required in: ɀ manufacturing plants and heavy industrial facilities ɀ industrial process facilities such as refineries, chemical, petrochemical, pharmaceutical, and production platforms ɀ waste or sewage treatment plants ɀ offshore, dockside and harbor installations ɀ for security and safety lighting in industrial facilities ɀ for lighting of loading docks, tunnels and stairways ɀ for marine, wet location, hosedown and corrosive environments ɀ Variety of lamp types and wattages—HID, fluorescent and induction—to meet specific lighting needs. ɀ High-power-factor ballasts (+90%) are standard, which allow more luminaires per circuit. ɀ Up to 65°C ambient suitability on select lamp types and wattages. Ambient suitability of +40°C is standard. Allows for installation in higher ambient environments commonly found in industrial facilities. ɀ Low ambient starting capability (to -40°C)—perfect for colder climates. ɀ Shock-absorbing HID mogul base lamp socket cushions lamp, improves lamp life in harsh environments. US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:867)) CH0 0 4 F - 5 CAN: 1-800-265-0502 ɀ Compact fluorescent emergency luminaire provides 90 minutes of lighting during power outages, meeting UL924 and life safety code. ɀ Cost-effective induction lamp system provides extra-long lamp life—up to 100,000 hours. Reaches full illumination immediately, providing crisp white light. ɀ NEC/CEC Restricted Breathing construction is available to provide cooler temperature classes (T codes) for expanded hazardous area suitability. ɀ Simplified method for compliance to NEC Restricted Breathing conduit sealing requirements makes installation easier. Copyright© 2006 Cooper Crouse-Hinds 867 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0868-12 Name: 7L-868 7L DATE: JAN 19 2006 Time: 5:57:25 PM Operator: RB Champ-Pak TM Wall Pack Luminaires COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 2, Groups A,B,C,D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups F & G Cl. III & Simultaneous Presence Marine & Wet Locations ɀ Enclosure Type 4X, IP66 STANDARD MATERIALS RATINGS (ELECTRICAL/SIZE) ɀ fixture housing and door frame assembly—copper-free aluminum ɀ external hardware—stainless steel ɀ refractor lens—borosilicate glass ɀ gasket—silicone ɀ reflector—aluminum light sheet ɀ wire guard—stainless steel Sources/Wattages STANDARD FINISHES ɀ aluminum—Corro-free TM epoxy powder coat ɀ stainless steel—natural ɀ high-pressure sodium (HPS)—mogul base ɀ metal halide (MH)—mogul base ɀ mercury vapor (MV)—mogul base ɀ compact fluorescent ɀ emergency fluorescent ɀ induction 50, 70, 100 & 150 70, 100 & 150 100 26, 32, 42, 52, 64 & 84 26 55 & 85 Voltages CERTIFICATIONS & COMPLIANCES Luminaires For Use With ANSI Lamps (Mogul Base) ɀ UL/cUL Listed ɀ NEC and CEC Class I, Division 2 and Class I, Zone 2 ɀ Restricted Breathing Class I, Division 2 and Zone 2 (suffix S826) ɀ Class II, Groups F and G ɀ Class III ɀ Simultaneous Presence ɀ Certified for IEC Zone 2 (suffix S826TB) ɀ Wet Locations; Marine Locations; Enclosure Type 4X; IP66 UL Standards ɀ 844—hazardous (divisions classified) locations ɀ 2279—hazardous (zones classified) locations ɀ 1598—luminaires ɀ 1598A—luminaires for marine vessels ɀ 924—emergency lighting (fluorescent emergency luminaire) CSA Standards ɀ C22.2 No. 9 and 137 ɀ CAN/CSA-E60079-15:02 HID STANDARD-VOLTAGE BALLASTS ɀ Dual tap (120 & 277 V, 60 Hz—for 50 W HPS only)— prewired at 277 V ɀ Multitap (120, 208, 240 & 277 V, 60 Hz)—prewired at 277 V ɀ Tritap (120, 277 & 347 V, 60 Hz)—prewired at 347 V ɀ 120 V, 60 Hz ɀ 480 V, 60 Hz FLUORESCENT STANDARD-VOLTAGE BALLASTS ɀ 120–277 V, 50–60 Hz ɀ 120 V, 50 Hz (for Canada only) ɀ 347 V, 60 Hz (for Canada only) INDUCTION STANDARD-VOLTAGE BALLASTS ɀ 120 V, 50–60 Hz (also 120 V DC) ɀ 230 V, 50–60 Hz (also 240 V DC) HID OPTIONAL VOLTAGE BALLASTS ɀ 220 V, 50 Hz ɀ 220 V, 60 Hz ɀ 240 V, 50 Hz FLUORESCENT OPTIONAL VOLTAGE BALLASTS (Consult Factory) ɀ 125 V DC ɀ 12 V DC ɀ 24 V DC IEC Standards ɀ 60079-15 ISOLATED BALLASTS AND SPECIALS (Consult Factory) ɀ 208 V, 60 Hz CWI Isolated Ballast ɀ 240 V, 60 Hz CWI Isolated Ballast ɀ 480 V, 60 Hz CWI Isolated Ballast Conduit Entries ɀ four 3⁄4⍯ NPT entries, one on each side, top and bottom (3 plugged) ɀ two 1⁄2⍯ NPT entries on bottom for feed-through (1 plugged) ɀ metric entries—consult factory 868 STIBOINFO((CRH:66008com:7L:868)) CH0 0 4 F - 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0869-18 Name: 7L-869 DATE: JAN 19 2006 Time: 5:57:26 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 2, Groups A,B,C,D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups F & G Cl. III & Simultaneous Presence Marine & Wet Locations ɀ Enclosure Type 4X, IP66 Champ-Pak TM Wall Pack Luminaires 7L ORDERING INFORMATION To complete Catalog Number, add Voltage and Option suffix(es). HID Luminaires Fluorescent Luminaires CATALOG NUMBER FOR USE WITH ANSI LAMPS LAMP WATTS HUB SIZE HIGH-PRESSURE SODIUM Four 3⁄4⍯ NPT (one each side) 50 Two 1⁄2⍯ NPT (on bottom) Four 3⁄4⍯ NPT (one each side) 70 Two 1⁄2⍯ NPT (on bottom) Four 3⁄4⍯ NPT (one each side) 100 Two 1⁄2⍯ NPT (on bottom) Four 3⁄4⍯ NPT (one each side) 150 (for 55 V lamp) Two 1⁄2⍯ NPT (on bottom) METAL HALIDE Four 3⁄4⍯ NPT (one each side) Two 1⁄2⍯ NPT (on bottom) Four 3⁄4⍯ NPT (one each side) Two 1⁄2⍯ NPT (on bottom) CPMVS2W050 CPMVS1W050 CPMVS2W070 CPMVS1W070 CPMVS2W100 CPMVS1W100 CPMVS2W150 CPMVS1W150 70 CPMVM2W070 CPMVM1W070 CPMVM2W100 CPMVM1W100 100 METAL HALIDE—PULSE START Four 3⁄4⍯ NPT (one each side) Two 1⁄2⍯ NPT (on bottom) 150 MERCURY VAPOR Four 3⁄4⍯ NPT (one each side) Two 1⁄2⍯ NPT (on bottom) 100 CPMVM2W150-S828 CPMVM1W150-S828 CPMVC2W100 CPMVC1W100 VOLTAGE SUFFIXES NEC (UL) Voltage (60 Hz) Dual Tap Multitap Suffix /DT /MT CEC (CSA/cUL) Voltage (60 Hz) Dual Tap Tritap Suffix /DT /TT 50 W HPS is available only with suffix /DT. 120 /120 480 /480 120 /120 Induction Luminaires With Lamp (100,000 hours) LAMP WATTS HUB SIZE Four 3⁄4⍯ NPT (one each side) Two 1⁄2⍯ NPT (on bottom) Four 3⁄4⍯ NPT (one each side) Two 1⁄2⍯ NPT (on bottom) 55 85 Suffix CATALOG NUMBER CPMVIG2W055 CPMVIG1W055 CPMVIG2W085 CPMVIG1W085 120 V (also 120 V DC) 230 V (also 240 V DC) (50–60 Hz) (50–60 Hz) /120 /230 US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:869)) CH0 0 4 F - 5 3⁄4⍯ NPT (one each side) Four Two 1⁄2⍯ NPT (on bottom) Four 3⁄4⍯ NPT (one each side) Two 1⁄2⍯ NPT (on bottom) Four 3⁄4⍯ NPT (one each side) Two 1⁄2⍯ NPT (on bottom) Four 3⁄4⍯ NPT (one each side) Two 1⁄2⍯ NPT (on bottom) Four 3⁄4⍯ NPT (one each side) Two 1⁄2⍯ NPT (on bottom) Four 3⁄4⍯ NPT (one each side) Two 1⁄2⍯ NPT (on bottom) 26 (one 26 W lamp) 32 (one 32 W lamp) 42 (one 42 W lamp) 52 (two 26 W lamps) 64 (two 32 W lamps) 84 (two 42 W lamps) CATALOG NUMBER CPMVF2W026 CPMVF1W026 CPMVF2W032 CPMVF1W032 CPMVF2W042 CPMVF1W042 CPMVF2W052 CPMVF1W052 CPMVF2W064 CPMVF1W064 CPMVF2W084 CPMVF1W084 VOLTAGE SUFFIXES Voltage Suffix NEC/CEC (UL, CSA, cUL) 120–277 V (50–60 Hz) /UNV CEC (CSA, cUL) 347 V (60 Hz) /347 Fluorescent Emergency Luminaires —Continuous Operation HUB SIZE Four 3⁄4⍯ NPT (one each side) Two 1⁄2⍯ NPT (on bottom) LAMP WATTS 26 (one 26 W lamp) CATALOG NUMBER CPMVFB2W026 CPMVFB1W026 VOLTAGE SUFFIXES Voltage Suffix NEC (UL) 120–277 V (50–60 Hz) /UNV CEC (CSA, cUL) 120 V 347 V (60 Hz) (60 Hz) /120 CAN /347 Compelling reasons to choose the new Champ Induction luminaire as the light source for industrial and hazardous locations include: VOLTAGE SUFFIXES Voltage LAMP WATTS HUB SIZE CAN: 1-800-265-0502 ɀ Crisp white light (80+ color rendering index) provides increased safety by clearly illuminating signs, instrument panels, equipment and more with vibrant natural colors. ɀ Up to 100,000 hours of lamp life minimizes routine maintenance costs. If you operate this luminaire for 24 hours, 7 days a week, you will not need to change the lamp for up to 11 years! ɀ Instant illumination — no waiting for lamp warm-up time. Increases productivity and safety. ɀ Delivers the best possible luminaire temperature rating — T6 (85°C) when used with the Champ restricted breathing option. Ideal for hazardous areas where a low ignition temperature is required. ɀ Starts in low temperatures — as low as -40°C. Copyright© 2006 Cooper Crouse-Hinds 869 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0870-17 Name: 7L-870 7L 100: DATE: JAN 19 2006 Time: 5:57:27 PM Operator: RB Champ-Pak TM Wall Pack Luminaires COLOR: CMYK TCP: 15001 Cl. I, Div. 2, Groups A,B,C,D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups F & G Cl. III & Simultaneous Presence Marine & Wet Locations ɀ Enclosure Type 4X, IP66 SUFFIX TO ADD TO SUFFIX TO ADD TO OPTIONS CATALOG NUMBER BALLAST-GARD TM STARTER CUT-OUT SWITCH ɀ prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life ɀ available for use with HPS only ɀ not available with IR or QTZ options FACTORY ASSEMBLED WITH LAMP INSTALLED INSTANT RESTRIKE ɀ enables a hot HPS lamp to immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage; it has no effect on the warm-up period of cold lamps ɀ available for use with HPS only ɀ not available with BG or QTZ options GUARD—FACTORY INSTALLED ON LUMINAIRE (Guard suffix follows wattage designation, e.g., CPMVS2W100P/MT) QUARTZ AUXILIARY ɀ quartz auxiliary lighting comes to full brightness immediately and remains lit until the HID lamp attains 60–70% of full illumination ɀ available for use with HID only ɀ for nonhazardous locations only ɀ quartz lamp not furnished—use 100 W singleended lamp Q100DC, Q100DL/DC or 100Q/CL/DC FUSED ɀ protects ballast and capacitors against abnormal line conditions (not for use in Canada or marine locations) ɀ not available with CPMVIG and CPMVFB luminaires RESTRICTED BREATHING CONSTRUCTION (AEx nR, Ex nR) Suitable for NEC/CEC Class I, Division 2 and Zone 2 ɀ provides cooler temperature classes (T codes) ɀ furnished with P55 guard BG FA IR P QTZ S658* OPTIONS V2PC PHOTOCELL— FACTORY INSTALLED ɀ 120 V, 50–60 Hz ɀ 208–240 V, 50–60 Hz ɀ 277 V, 50–60 Hz OPTIONAL VOLTAGE BALLASTS FOR HID LUMINAIRES ɀ 220 V, 50 Hz ɀ 220 V, 60 Hz ɀ 240 V, 50 Hz S826 /208CWI /240CWI /480CWI PHOTOCELL FOR FIELD INSTALLATION ɀ 120 V, 50–60 Hz ɀ 208–240 V, 50–60 Hz ɀ 277 V, 50–60 Hz In Canada, use factory-installed photocell only. NOTE: Approximate weight less guard 28 lbs. P55 guard 0.5 lbs. STIBOINFO((CRH:66008com:7L:870)) /220 50 /220 60 /240 50 ISOLATED BALLAST FOR HID LUMINAIRES (Consult Factory) ɀ 208 V, 60 Hz ɀ 240 V, 60 Hz ɀ 480 V, 60 Hz DIMENSIONS (INCHES) CH0 0 4 F - 5 /V2PC20 /V2PC22 /V2PC27 /125 VDC /12 VDC /24 VDC STAINLESS STEEL WIRE GUARD CAN: 1-800-265-0502 S826TB OPTIONAL VOLTAGE BALLASTS FOR FLUORESCENT LUMINAIRES (Consult Factory) ɀ 125 V DC ɀ 12 V DC ɀ 24 V DC * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. US: 1-866-764-5454 CATALOG NUMBER CERTIFIED FOR IEC ZONE 2 (Ex nR) (UL CLASSIFIED TO THE IEC STANDARD) Furnished with: ɀ 4 mm2, 3-point terminal block ɀ crimp internal wiring connections ɀ P55 guard ACCESSORIES (ORDER SEPARATELY) TEFLON is a registered trademark of E.I. duPont Co. 870 Typedriver Name: TS name csm no.: 100 Copyright© 2006 Cooper Crouse-Hinds CATALOG NUMBER V2PC20 V2PC22 V2PC27 P55 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0871-33 Name: 7L-871 100: DATE: JAN 19 2006 Champ-Pak TM Wall Pack Luminares Time: 5:57:28 PM Operator: JB COLOR: CMYK TCP: 15001 Photometric Data Typedriver Name: TS name csm no.: 100 7L CPMV PHOTOMETRIC DATA LUMINAIRE WITH REFRACTOR LESS WIRE GUARD CPMVS2W150 Lamp: 150 W/E23-1/2 Clear High Pressure Sodium (HPS) CANDELAS Vertical Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 Front Side Back 413 413 413 470 418 367 877 654 265 1343 947 169 1629 1135 126 1614 1369 68 2434 1267 17 2505 1281 0 2084 916 4 1555 322 8 1148 265 11 956 228 8 723 156 9 527 86 9 355 56 8 224 40 4 150 20 1 64 11 1 19 9 3 0 8 1 3 3 3 ZONAL LUMENS Zone Lumens 0-10 42 10-20 178 20-30 371 30-40 587 40-50 760 50-60 1095 60-70 1277 70-80 1028 80-90 666 90-100 462 100-110 338 110-120 236 120-130 175 130-140 91 140-150 31 150-160 10 160-170 2 170-180 0 Total 7349 LUMINAIRE WITH REFRACTOR LESS WIRE GUARD CPMVM2W150-S828 Lamp: 150 W/ED28 Clear Pulse Start Metal Halide CANDELAS Vertical Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 Front Side Back 404 404 404 442 424 413 692 549 238 1345 748 136 1475 946 99 1683 1121 56 2105 1095 15 2421 1107 3 2230 924 0 1946 349 0 1612 280 0 1154 231 0 738 164 0 535 97 0 360 55 0 237 39 0 139 22 0 56 12 0 17 8 0 0 8 0 3 3 0 ZONAL LUMENS Zone Lumens 0-10 42 10-20 150 20-30 320 30-40 537 40-50 709 50-60 921 60-70 1218 70-80 1153 80-90 829 90-100 492 100-110 347 110-120 242 120-130 167 130-140 113 140-150 35 150-160 10 160-170 2 170-180 0 Total 7287 For additional photometric data, contact Cooper Crouse-Hinds. US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:871)) CH0 0 4 F - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 871 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0872-9 Name: 7L-872 7L 100: DATE: JAN 19 2006 Time: 5:57:33 PM Operator: JB COLOR: CMYK TCP: 15001 Photometric Data Champ-Pak TM Wall Pack Luminaires LUMINAIRE WITH REFRACTOR LESS WIRE GUARD CPMVF2W084 Lamps: (2) PL-T 42W/30/4P Compact Fluorescent CANDELAS Vertical Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 Front 258 319 421 516 590 671 720 725 657 566 541 526 409 277 145 97 52 34 8 0 0 Side 258 269 316 361 376 362 347 317 264 195 160 132 86 49 31 21 11 3 1 0 0 Back 258 227 139 58 33 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ZONAL LUMENS Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Total Lumens 26 87 155 223 286 334 357 349 309 262 188 113 64 36 16 5 0 0 2810 LUMINAIRE WITH REFRACTOR LESS WIRE GUARD CPMVIG2W055 Lamp: 55 W Philips Induction Lamp System CANDELAS Vertical Angle 0 5 15 25 35 45 55 65 75 85 90 95 105 115 125 135 145 155 165 175 180 Front 241 290 352 414 427 475 462 439 364 330 309 276 206 121 80 55 32 21 5 0 1 Side 241 243 259 268 274 295 306 285 214 124 86 63 38 28 20 18 8 5 2 2 1 Back 241 199 110 45 28 12 3 0 0 1 2 2 2 1 2 1 1 2 0 0 1 ZONAL LUMENS Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Total Lumens 23 70 114 154 194 224 228 205 169 130 86 52 34 21 9 3 1 0 1717 For additional photometric data, contact Cooper Crouse-Hinds. 872 STIBOINFO((CRH:66008com:7L:872)) CH0 0 4 F - 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0873-18 Name: 7L-873 DATE: JAN 19 2006 Time: 5:57:39 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Temperature Performance Data Champ-Pak TM Wall Pack Luminaires 7L TEMPERATURE PERFORMANCE DATA AMBIENT WATTS Temp °C HIGH-PRESSURE SODIUM 50 40 55 65* 70 40 55 65* 100 40 55* 150 40* CLASS I DIVISION 2 and ZONE 2 RESTRICTED BREATHING STANDARD AEx nR/Ex nR PRODUCT OPTION S826 CLASS II and CLASS III T3A T3A T3 T3A T3A T3 T2C T2C T2B T6 T6 T5 T6 T6 T5 T5 T4 T4 40 55 65* 40 40 T3C T3C T3C T3 T2D T6 T6 T5 T6 T5 T5 — — — — MERCURY VAPOR 100 40 55* T2C T2B T5 T4 COMPACT FLUORESCENT 26 40 26 (347 V) 55 40 32 40 55 32 (347 V) 40 42 (120–277 V) 40 42 (347 V) 55 40 52 40 55 64 40 55 84 40 T3B T3A T3 T3B T3A T3 T3B T3A T3 T3 T3 T3 T3 T2C EMERGENCY FLUORESCENT 26 40* METAL HALIDE 70 100 150PS (S828) INDUCTION 55 85 40* 55* 40* SIMULTANEOUS PRESENCE CLASS I/CLASS II (Gas and Dust Present in the Same Area) RESTRICTED BREATHING STANDARD AEx nR/Ex nR PRODUCT OPTION S826 Suitable for Class I. Suitable for Class I, Division 2 Division 2/Class II or Zone 2 and Class II T5 T3A/T5 T4A* T3/T4A* — — T5 T3A/T5 — — — — Consult Factory for Class II Suitability with 105°C Supply Wire — — T5 T4* — T5 — — SUPPLY WIRE TEMP °C — 90 105 105 90 105 105 90 105 105 T3C/T5 — — — — T5 — — — — 90 105 105 90 105 — — — — — — 90 105 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 T6 — — T6 — — T6 — — T6 — T6 — — T3B/T6 — — T3B/T6 — — T3B/T6 — — T3/T6 — T3/T6 — — T6 — — T6 — — T6 — — T6 — T6 — — 75 75 75 75 75 75 75 75 75 75 90 75 90 90 T3B T6 — — — 75 T2D T2D T2B T6 T6 T6 T6 — — — — — T6 — — 75 75 75 *Fuses (suffix S658) are not available for indicated light sources and ambient temperatures. NOTE: Luminaires requiring 105°C supply wire are furnished with 3 ft. of rated wire for external wiring connection US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:873)) CH0 0 4 F - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 873 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0874-8 Name: 7L-874 7L 100: DATE: JAN 19 2006 Time: 5:58:32 PM Operator: RB Champ® Voyager nR TM Stainless Steel Floodlight COLOR: CMYK TCP: 15001 Cl. I, Div. 2, Groups A,B,C & D Cl. I, Zone 2, Group IIC Enclosure Type 4X IP66 UL and cUL Listed Typedriver Name: TS name csm no.: 100 Wet Locations Marine Locations At last, a hazardous-area luminaire with complete stainless steel exterior, low temperature ratings and standard with the restricted breathing rating (vaportight design). Cooper Crouse-Hinds® Champ Voyager nR stainless steel floodlight offers the industry’s coolest temperature. ratings—so it can operate below the ignition temperature of vapors and gases in your classified area. It’s also the only mogul-base Class I, Division 2 and Zone 2 stainless steel floodlight with restricted breathing (vapor-tight design) as standard construction. The Champ Voyager nR Floodlight boasts a wide, powerful beam to deliver more light to your process or pathway. Standard terminal blocks and a removable ballast-component tray bring you the best combination of easy wiring and simple maintenance in one rugged package. This unique combination of features makes the Champ Voyager nR Floodlight ideal for outdoor, marine, corrosive, and high temperature locations such as: ɀ offshore platforms and drilling rigs, ship channels and refineries ɀ chemical, petrochemical and pharmaceutical plants, waste water and sewage treatment plants, pulp and paper mills ɀ storage tanks and racks, vehicle and pedestrian passageways, outdoor process areas and parking areas And because the Champ Voyager nR Floodlight meets international standards, you can install it anywhere in the world. KEY FEATURES AND BENEFITS ɀ AEx nR, Ex nR restricted breathing rating is standard—a hazardous location luminaire with excellent T-3 and T-4 ratings without additional accessories or options. ɀ NEMA 7x6 ‘‘butterfly beam’’ floodlight pattern—wide, uniform and far reaching to reduce the number of luminaires you need providing excellent luminaire efficiency—more light where you need it. ɀ easy wiring—standard terminal block with marked terminals saves time and eliminates wiring errors. ɀ removable ballast-component tray—for capacitor, igniter and terminal block to simplify maintenance and save money. ɀ 316 stainless steel housing, hinges, door cover and mounting yoke for marine and wet locations—robust construction suitable for saltwater and corrosive applications. Removable ballast component tray Easy wiring with standard terminal blocks 874 STIBOINFO((CRH:66008com:7L:874)) CH0 0 4 F - 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0875-14 Name: 7L-875 DATE: JAN 19 2006 Champ® Voyager nR TM Stainless Steel Floodlight Time: 5:58:34 PM Operator: GK COLOR: CMYK Cl. I, Div. 2, Groups A,B,C & D Cl. I, Zone 2, Group IIC Enclosure Type 4X IP66 UL and cUL Listed CERTIFICATIONS AND COMPLIANCES NEC/CEC ɀ Class I, Division 2 ɀ Class I, Zone 2 ɀ Wet Locations ɀ Marine Locations ɀ Enclosure Type 4X, IP66 ɀ UL Listed ɀ cUL Listed (Certified by UL to CSA Standards) IEC/NEC/CEC ɀ Class I, Zone 2, Group IIC ɀ Class I, Division 2, Group A,B,C,D UL STANDARDS ɀ 844 — Hazardous (Divisions Classified) Locations ɀ 1598 — Luminaires ɀ 1598A — Supplemental requirements for luminaires for installation on marine vessels. TCP: 15001 Typedriver Name: TS name csm no.: 100 Wet Locations Marine Locations 7L STANDARD MATERIALS RATINGS ɀ Enclosure (housing & lens frame)—316 Stainless Steel ɀ Lens—heat and impact resistant tempered glass ɀ Gaskets—silicone rubber ɀ Yoke and yoke bracket—316 Stainless Steel ɀ Reflector—formed specular (dimpled glossy surface) aluminum ɀ Cable gland cord grip and locknut— polyamide 6, neoprene bushing SOURCES/WATTAGES (MOGUL BASE LAMPS) ɀ High Pressure Sodium (HPS) 150, 250 & 400 watts ɀ Metal Halide (MH) 175, 250 & 400 watts STANDARD FINISHES ɀ 316 Stainless Steel—natural VOLTAGES Standard Voltage Ballasts ɀ Multi-tap (120, 208, 240 & 277 V, 60 Hz) ɀ 480 V, 60 Hz ɀ Tri-tap (120, 277, 347 V, 60 Hz) Optional Voltage Ballasts ɀ 220 V or 240 V, 50 Hz (for export) ɀ 220 V, 60 Hz (for export) Isolated Ballasts (consult Cooper Crouse-Hinds) ɀ 208, 240, or 480 V (for Canada) HUB SIZE ɀ Standard: 3⁄4⍯ NPT with a 3⁄4⍯ sealing cord grip installed CSA STANDARDS ɀ C22.2 No. 137 ɀ CAN/CSAD9 Series IEC STANDARDS ɀ .60079-15 ORDERING INFORMATION DIMENSIONS (inches) To complete catalog number, add voltage and option suffix(es) Example: SSFMVSY150/MT-76 BG-FA LAMP TYPE WATTS CATALOG NUMBER High-Pressure Sodium Metal Halide 150 250 400 175 250 400 SSFMVSY150 SSFMVSY250 SSFMVSY400 SSFMVMY175 SSFMVMY250 SSFMVMY400 VOLTAGE SUFFIXES VOLTAGE (60 Hz) Tri-tap (120, 277, 347, 60 Hz) Multi-tap (120, 208, 240, 277V, 60 Hz) 480 V, 60 Hz SUFFIX /TT /MT /480 OPTIONAL VOLTAGES 220 50 Hz 220 60 Hz 240 50 Hz SUFFIX TO ADD TO CAT. NO. OPTIONS Ballast-Gard TM starter cut-out switch prevents starter pulsing when lamp is cycling or inoperative. Prolongs ballast and igniter life 150 W HPS only. Not available with options IR or QTZ BG Factory assembled w/HID lamp installed FA Instant restrike—150W HPs only. Not available with options BG or QTZ IR Quartz auxiliary (lamp not supplied). For non-hazardous applications only. Not available with options BG or IR QTZ Fused (not for marine or cUL) S658 ACCESSORIES (order separately) LUMINAIRE WEIGHTS CATALOG NO. Stainless Steel Slipfitter Adapter SFA6 SS Stainless Steel Wall Mount Bracket SWB6 SS Standard Slipfitter adapter (cast aluminum, epoxy coat) SFA6 Standard Wall Mount bracket (cast aluminum, epoxy coat) SWB6 US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:875)) CH0 0 4 F - 5 SUFFIX /220 50 /220 /240 50 CAN: 1-800-265-0502 LUMINAIRE HPS (lbs.) MH 150W 39 — 175W — 39 250W 43 41 400W 45 43 Copyright© 2006 Cooper Crouse-Hinds 875 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0876-6 Name: 7L-876 DATE: JAN 19 2006 Time: 5:58:35 PM Operator: RB Champ® Voyager nR TM Stainless Steel Floodlight 7L COLOR: CMYK TCP: 15001 Cl. I, Div. 2 Cl. I, Zone 2 Enclosure Type 4X IP66 UL and cUL Listed Typedriver Name: TS name csm no.: 100 Wet Locations Marine Locations PHOTOMETRICS HPS Wide Beam Reflector MH Wide Beam Relfector ISO FOOTCANDLE CHART Stainless Steel Floodlight 400 W High Pressure Sodium (HPS) Catalog Number: SSMVSY400/MT Lamp: 400 W Clear HPS Lumen Rating: 50,000 Luminaire located at 0,0° Aiming Angle at 45° down from horizontal For 150 W HPS, multiply footcandles by 0.32. For 250 W HPS, multiply footcandles by 0.57. MOUNTING FOOTCANDLE VALUES FOR HEIGHT ISO FOOTCANDLE LINES A B C D E F 10′ 40.000 20.000 8.000 4.000 2.000 0.800 15′ 17.778 8.889 3.555 1.778 0.889 0.356 20′ 10.000 5.000 2.000 1.000 0.500 0.200 25′ 6.400 3.200 1.280 0.640 0.320 0.128 30′ 4.444 2.222 0.889 0.444 0.222 0.089 35′ 3.265 1.633 0.653 0.327 0.163 0.065 40′ 2.500 1.250 0.500 0.250 0.125 0.050 ISO FOOTCANDLE CHART Stainless Steel Floodlight 400 W Metal Halide (MH) Catalog Number: SSFMVMY400/MT Lamp: 400 W Clear MH Lumen Rating: 34,000 Luminaire located at 0,0° Aiming Angle at 45° down from horizontal For 175 W MH, multiply footcandles by 0.42 For 250 W HPS, multiply footcandles by 0.65 MOUNTING FOOTCANDLE VALUES FOR HEIGHT ISO FOOTCANDLE LINES A B C D E F 10′ 20.000 8.000 4.000 2.000 0.800 0.400 15′ 8.889 3.555 1.778 0.889 0.356 0.178 20′ 5.000 2.000 1.000 0.500 0.200 0.100 25′ 3.200 1.280 0.640 0.320 0.128 0.064 30′ 2.222 0.889 0.444 0.222 0.089 0.044 35′ 1.633 0.653 0.327 0.163 0.065 0.033 40′ 1.250 0.500 0.250 0.125 0.050 0.025 TEMPERATURE PERFORMANCE DATA EFFECTIVE PROJECTED AREA (EPA) AMBIENT TEMP. 150 W HPS 250 W HPS 400 W HPS 175 W MH 250 W HPS 400 W MH DIV. 2 40°C T1(350°C) T1(350°C) T1(400°C) T1(325°C) T1(325°C) T1(325°C) 876 STIBOINFO((CRH:66008com:7L:876)) CH0 0 4 F - 5 DIV. 2 55°C T1(350°C) T1(350°C) — T1(325°C) T1(325°C) — SUPPLY SUPPLY ZONE 2 ZONE 2 WIRE 0°C WIRE 0°C 40°C 55°C (40°C) (55°C) T4 T3 90°C 105°C T4 T3 90°C 105°C T3 — 90°C — T3 T3 90°C 105°C T3 T3 90°C 105°C T3 — 105°C — US: 1-866-764-5454 CAN: 1-800-265-0502 ɀ For windloading AIMING ANGLE 0 degrees 30 degrees 60 degrees ɀ For proper pole selection EPA 2.15 ft2 1.86 ft2 1.07 ft2 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0877-5 Name: 7L-877 100: DATE: JAN 19 2006 Time: 5:58:36 PM Operator: RB ɀ ɀ ɀ ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) 50-175W F2MV Series Champ® H.I.D. Luminaires COLOR: CMYK Ratings (Electrical/Size): Champ F2MV floodlights are used: ɀ on platforms and in refineries, chemical and petrochemical plants, pharmaceutical plants, waste water and sewage treatment plants, pulp and paper mills, and other outdoor as well as indoor industrial locations. ɀ to light outdoor industrial applications such as storage tanks and racks, vehicle and pedestrian passageways, outdoor process areas, and parking areas in industrial facilities. ɀ for security & safety lighting in industrial and process facilities. ɀ in high ambient temperatures. ɀ in marine and wet locations ɀ in outdoor locations where the damaging effects of rain, snow, wind, dirt & other contaminants are present ɀ in Class I, Division 2 hazardous (classified) locations as defined by the NEC & CEC ɀ in Class I, Zone 2 hazardous (classified) areas as defined by the NEC & CEC ɀ in Zone 2 hazardous (classified) areas as defined by the IEC Sources/Wattage (Mogul Base Lamps) ɀ High Pressure Sodium (HPS) 50, 70, 100 & 150 ɀ Metal Halide (MH) 70, 100, & 175 ɀ Mercury Vapor (MV) 100 & 175 Voltages Standard Voltage Ballasts ɀ Multi-tap (120, 208, 240 & 277 volts 60 Hz) ɀ Dual tap (120, 277 volts 60 Hz) — 50W HPS only ɀ 480 volts 60 Hz ɀ Tri-tap (120, 277. 347 volts 60 Hz). ɀ For use with other accessories ɀ SFA-6 Slip Fitter Adapter ɀ SWMB-6 Wall Mount Bracket ɀ Restricted Breathing sealing compliance ɀ Severe vibration testing compliance ɀ UL 844 ɀ 3-Axis Resonance Withstand Optional Voltage Ballasts (consult Cooper Crouse-Hinds) ɀ 220 volt or 240 volt 50 Hz (for export) ɀ 220 volt 60 Hz (for export) ɀ Isolated Ballasts 208, 240 or 480 volt (For Canada) Hub Sizes ɀ Standard — (2) 3⁄4⍯ NPT ɀ Optional — (2) 25mm (M25x1.5) Benefits Robust design, Industrial grade construction Insures wet & marine locations integrity Easy to install & maintain Provides specifiers with the right product for the task at hand. Most common for industrial applications Addresses high ambients common at industrial facilities Ease of maintenance Perfect for colder climates Cushions lamp, improves lamp life in harsh environments Meets global supply voltage requirements Standard construction provides the greatest mounting flexibility — can be mounted vertically (wall), horizontally (floor) or any angle in between Further enhances mounting flexibility Complies with the NEC sealing requirements for Class I Zone 2 and Class I Division 2 locations using the standard wiring method of a Cooper Crouse-Hinds CGB 294SA connector with 16/3 SO extra hard usage cord Exceeds vibration tests as required by UL Standard Materials: ɀ Enclosure (housing & lens cover) — copper-free aluminum ɀ Cover chain and external hardware — stainless steel ɀ Lens — heat & impact resistant glass ɀ Gaskets — silicone rubber ɀ Yoke — galvanized steel ɀ Reflector — diffuse aluminum lighting sheet Standard Finishes: Enclosure & Yoke — Corro-free epoxy powder coat ɀ Stainless steel — natural * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:877)) CH0 0 7 L - 4 CAN: 1-800-265-0502 Typedriver Name: TS name csm no.: 100 Marine & Wet Locations 3, 3R, 4, 4X; IP66 Application: Key Features ɀ Copper free aluminum enclosure with stainless steel hardware ɀ Continuous silicone gasketing ɀ Small compact size ɀ Available in a variety of lamp sources and wattages ɀ NEMA 7x6 standard floodlight pattern with lamp orientation base down ɀ 40° and 55°C ambient suitability standard with some wattages (less fuses) to 65°C ɀ Stainless steel chain secures cover to housing ɀ Low ambient capability to –40°C ɀ Shock absorbing mogul base lamp socket ɀ Variety of system voltages available ɀ Trunnion (yoke) mount design TCP: 15001 7L Certifications and Compliances: ɀ NEC/CEC: Class I Division 2, Groups A, B, C, D Class I Zone 2 ɀ IEC: Zone 2 Ex nR IIC ɀ UL Standards: 844, 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards: C22.2 No. 137: ɀ IEC Standards: 60079-15 Options: Suffix to be Description Added to Cat. No. BG ɀ Ballast-Gard -50-150W HPS only -Cannot use with options IR or QTZ ɀ Factory assembled w/HID lamp installedFA ɀ Instant Restrike IR -50-150W HPS only -Cannot use with options BG or QTZ ɀ Quartz auxiliary (lamp not supplied) QTZ -For nonhazardous applications only. -Cannot use with options BG or IR ɀ Fused S658* ɀ Restricted Breathing, (AEx nR, Ex nR) S826 -For NEC/CEC Class I Zone 2 ɀ Restricted Breathing (Ex nR) S826TB for IEC Zone 2. Includes: -3pt. 4mm squared terminal block -Crimp internal wiring connections -For use with dedicated voltages only -(not DT, MT, TT) ɀ V2PC Photocell Available Factory Installed Only Consult CrouseHinds Accessories: (Order Separately) ɀ SFA-6 Slipfitter adapter ɀ SWB-6 Wall Mount bracket Description Suffix to be added to Cat. No. ɀ Restricted Breathing Construction S826 Class I Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 (Suffix S826TB) S826TB Furnished with ɀ Terminal Block ɀ Crimp Terminals ɀ Dedicated voltage ballasts (no MT, DT or TT). Copyright© 2006 Cooper Crouse-Hinds 877 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0878-2 Name: 7L-878 7L DATE: JAN 19 2006 Time: 5:58:37 PM Operator: JB COLOR: CMYK ɀ ɀ ɀ ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) 50-175W F2MV Series Champ® H.I.D. Luminaires TCP: 15001 Marine & Wet Locations 3, 3R, 4, 4X; IP66 Temperature Performance Data Ordering Information *To complete Catalog Number, add Voltage and Option suffix(s) Example: F2MVSY150/MT-BG-FA-S658-S826 Lamp Type High Pressure Sodium Metal Halide Pulse Start Metal Halide Mercury Vapor Lamp Watts Base Catalog Number* with with 3⁄4⍯ NPT Hub 25MM Hub F2MVSY050 F2MVS25Y050 F2MVSY070 F2MVS25Y070 F2MVSY100 F2MVS25Y100 F2MVSY150 F2MVS25Y150 F2MVMY070 F2MVM25Y070 F2MVMY100 F2MVM25Y100 F2MVMY175 F2MVM25Y175 F2MVMY150-S828 F2MVMY175-S828 F2MVCY100 F2MVC25Y100 F2MVCY175 F2MVC25Y175 50 70 100 150 70 100 175 150 175 100 175 Voltage Suffixes Voltage (60Hz) Suffix Dual-Tap (50W HPS) /DT Typedriver Name: TS name csm no.: 100 Tri-Tap Multi-Tap 480 /TT /MT /480 Class 1 Non Restricted Breathing Division 2 Restricted Breathing (S826TB) Zone 2 Supply Wire °C T3C T3C T3B T3A T3A T3 T2D T2C n/a T2A T2A T2A T6 T5 T5 T6 T5 T4 T4 T4 n/a T4 T4 T3 75 75 75 60 75 85 75 90 n/a 75 85 110 40 55 65 40 55 65 40 55 65** T3C T3A T3A T2D T2D T2C T2A T2A T2 T6 T5 T4 T4 T4 T4 T3 T3 T3 75 75 85 75 75 85 75 85 110 Mercury Vapor 100 Watt 40 55 65 175 Watt 40 55 65** T2B T2B T2A T2B T2A T2A T4 T4 T4 T3 T3 T3 75 85 90 75 85 110 Lamp Watts Ambient Temp °C High Pressure Sodium 50 Watt 40 55 65 70 Watt 40 55 65 100 Watt 40 55 65 150 Watt 40 55 65** Metal Halide 70 Watt 100 Watt 175 Watt *Restricted breathing explosion protection **Suitable for use in 65°C ambient without optional fuses Dimensions and Weights: Aiming Range Luminaire Weight: 26 lbs. 878 STIBOINFO((CRH:66008com:7L:878)) CH0 0 7 L - 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0879-2 Name: 7L-879 100: DATE: JAN 19 2006 Time: 5:58:39 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data 50-175W F2MV Series 7L ® Champ H.I.D. Luminaires Isofootcandle Chart F2MV 150W High Pressure Sodium Catalog Number F2MVSY150 Lamp: 150 watt clear high pressure sodium Lumen rating: 16,000 For 100W high pressure sodium, multiply footcandles by .55 For 70W high pressure sodium, multiply footcandles by .40 For 50W high pressure sodium, multiply footcandles by .24 Isofootcandle Chart F2MV 175W Metal Halide Catalog Number F2MVMY175 Lamp: 175 watt clear metal halide Lumen rating: 14,000 For 100W metal halide, multiply footcandles by .58 For 70W metal halide, multiply footcandles by .37 Footcandle Table Isofootcandle Chart F2MV 175W Mercury Vapor Catalog Number F2MVCY175 Lamp: 175 watt clear mercury vapor Lumen rating: 8,600 For 100W mercury vapor, multiply footcandles by .49 Mounting Height 10′ 15′ 20′ 25′ 30′ Footcandle Values for Isofootcandle Lines A B C 8.00 4.00 2.00 3.56 1.78 0.89 2.00 1.00 0.50 1.28 0.64 0.32 0.89 0.44 0.22 D 0.80 0.36 0.20 0.13 0.09 E 0.40 0.18 0.10 0.06 0.04 Effective Projected Area (EPA) ɀ For windloading ɀ For proper pole selection Aiming Angle EPA 0° 1.6 ft2 30° 1.6 ft2 60° 1.1 ft2 Luminaire located a 0°, 0° Aiming angle 45° Note: Luminaire aiming angle limited to 30° past vertical through 60° before vertical. US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:879)) CH0 0 7 L - 6 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 879 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0880-7 Name: 7L-880 7L 100: DATE: JAN 19 2006 COLOR: CMYK Series Champ® H.I.D. Luminaires TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) 150-400W FMV Application: Time: 5:58:40 PM Operator: JB Marine & Wet Locations 3, 3R, 4, 4X; IP56 to IP66 Electrical Rating Ranges: Champ FMV Floodlights are used: ɀ in refineries, chemical and petrochemical plants, waste and sewage treatment plants, pulp and paper mills, and other outdoor industrial locations. ɀ to light outdoor industrial applications such as storage tanks and racks, vehicle and pedestrian passageways, outdoor process areas, and parking areas in industrial facilities. ɀ for security and safety lighting in industrial and process facilities. ɀ in Class I, Division 2 hazardous (classified) locations, as defined by the National Electrical Code. ɀ in high ambient temperatures ɀ in wet locations/marine locations ɀ in outdoor locations where the damaging effects of rain, snow, wind, dirt, and other contaminants are present. Features: ɀ Available in a wide variety of light sources and wattages: 70-400 watt high pressure sodium, 175-400 watt metal halide, and 175-400 watt mercury vapor. ɀ Multi-tap ballasts are standard, offering a choice of 120, 208, 240, and 277 volts. 220V 50 Hz, 240V 50 Hz, Tri-Tap (120, 277 and 347) and 480 volt ballasts are also available. ɀ All luminaires are high power factor for energy efficient operation and optimal circuit conductor sizing. ɀ Three mounting styles – yoke (trunnion), slipfitter adapter & wall mount bracket – are available to satisfy all mounting requirements. ɀ Door frame assembly is hinged and has captive cover screws for ease of relamping. ɀ Silicone rubber gaskets are standard, ensuring long life and reliable environmental sealing even under adverse conditions. ɀ All die-cast aluminum components are provided with powder epoxy finish for superior corrosion resistance. ɀ All external hardware is stainless steel for corrosion resistance and reliability. ɀ Yoke is aluminum for excellent combination of strength, corrosion resistance and durability. ɀ All FMV Champ floodlights can be easily adjusted to aim light where it is needed. ɀ NEMA 7x6 beam spread is ideal for most industrial floodlighting requirements. ɀ Includes ballast core handle for convenient ballast replacement. ɀ Wing-type ballast insulators protect personnel during maintenance and relamping and provide quick and easy accessibility to internal components. ɀ 70-150 (HPS), 175, 250, 400 watt ɀ Multi-tap刁 (120, 208, 240, 277 volts), 480 volts and 220V, 240V 50 Hz. ɀ Tri-tap (120, 277, 347 volts) ɀ NEC/CEC: Class I, Division 2, Groups A,B,C,D Class I Zone 2 ɀ IEC: Zone 2 Ex nR IIC ɀ UL Standards: 844, 2279 Hazardous (classified) locations 1598 Luminaires 1598A Marine locations ɀ CSA Standards: C22.2 No. 137 ɀ IEC Standards: 60079-15 Ordering Information: (For Voltages, See Note 1) High Pressure Sodium Metal Halide Pulse Start Metal Halide Mercury Vapor Lamp Watts 150 (See Note 2) 250 400 175 250 400 250 320 400 175 250 400 Notes to Ordering Information 1. Catalog numbers shown are for multi-tap ballasts (120, 208, 240, or 277 volt; wired for 277 volt operation). 220 V 50 Hz, 240 V 50 Hz, and 480 volts ballasts also available. To order with other ballasts, change ‘‘MT’’ in catalog number to appropriate voltage. Example: FMVSY400/220-50-76. For Tri-tap ballast (120, 277, 347 volts) change MT to TT. 2. 150 watt HPS luminaires are furnished with ANSI spec./S55 ballasts for 55 volt lamps. 3. Luminaires are furnished with a 3⁄4⍯ NPT drilled and tapped entrance. Accessories (Order Separately) Cat. No. Slipfitter adapter (To be mounted to yoke mount luminaire) . . . . . . . . . . . . SFA6 (Note: SFA6 fits onto 2⍯ pipe/conduit) Wall bracket (use with slipfitter adapter SFA6 for easy wall mounting & increased adjustability.) . . . . . . . . . . . . . . . . . . . SWB6 Options Suffix to be Description Added to Cat. No. Fused (not available with IR) . . . . . . . . . . . . S658刁 Quartz auxiliary . . . . . . . . . . . . . . . . . . . . . . . . . QTZ ɀ Non-hazardous locations only. ɀ Lamp not furnished Instant restrike . . . . . . . . . . . . . . . . . . . . . . . . . . . . IR ɀ Cannot be used with BG or QTZ. ɀ 50-150W LX HPS only. Ballast Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG ɀ Restricted Breathing Construction. . . . . . . S826 Class I Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 . . . . . . . . . . . . . S826TB Furnished with Terminal Block Crimp Terminals Dedicated voltage ballasts (no MT, DT or TT). 刁 CSA certified luminaires are not available with multi-tap ballasts * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Standard Finishes: ɀ Die-cast aluminum – epoxy powder coat ɀ Stainless steel – natural. STIBOINFO((CRH:66008com:7L:880)) US: 1-866-764-5454 Yoke Mount FMVSY150/MT-76 FMVSY250/MT-76 FMVSY400/MT-76 FMVMY175/MT-76 FMVMY250/MT-76 FMVMY400/MT-76 FMVMY250/MT-76 S828 FMVMY320/MT-76 S828 FMVMY400/MT-76 S828 FMVCY175/MT-76 FMVCY250/MT-76 FMVCY400/MT-76 or fusing option. ɀ Luminaire housing and door frame assembly – die-cast aluminum. ɀ External hardware – stainless steel. ɀ Lens – heat and impact-resistant glass. ɀ Yoke – aluminum. CH0 0 7 L - 8 Yoke mounted FMV Champ floodlight with SFA6 slipfitter adapter. Certifications and Compliances: Standard Materials: 880 Typedriver Name: TS name csm no.: 100 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0881-2 Name: 7L-881 DATE: JAN 19 2006 Time: 5:58:41 PM Operator: JB 150-400W FMV Series ® Champ H.I.D. Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Dimensions 7L Isofootcandle Chart FMV 400W high pressure sodium Catalog number FMVSY400-76 Lamp: 400 watt clear high pressure sodium Lumen rating: 50,000 Isofootcandle Chart FMV 400W metal halide Catalog number FMVMY400-76 Lamp: 400 watt clear metal halide Lumen rating: 34,000 For 150 watt high pressure sodium, multiply footcandles by 0.32. For 250 watt superior high pressure sodium, multiply footcandles by 0.6. For 250 watt clear metal halide, multiply footcandles by 0.6. Luminaire located at 0°, 0° Aiming angle at 45° (Note: Luminaire aiming angle limited to 30° past vertical through 60° before vertical.) 0°=2.9 30°=2.5 45°=2.1 ɀ 50 hertz ballast – luminaires can be ordered with either 220V 50 hertz or 240V 50 hertz ballasts. ɀ Ballast-Gard TM starter cut-out switch – prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 70-400W HPS only . . . . . . . . . . . . . . add suffix BG. Dimensions US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:881)) Luminaire located at 0°, 0° Aiming angle at 45° (Note: Luminaire aiming angle limited to 30° past vertical through 60° before vertical.) Table of Footcandle Values at Various Mounting Heights FMV 400W EPA Data – Aiming Angle CH0 0 7 L - 9 COLOR: CMYK CAN: 1-800-265-0502 Footcandle Values for both Isofootcandle Charts Mounting Height A B C 15′ 8.0 4.0 2.0 20′ 4.5 2.3 1.1 25′ 2.9 1.4 0.7 30′ 2.0 1.0 0.5 35′ 1.5 0.7 0.4 40′ 1.1 0.6 0.3 Copyright© 2006 Cooper Crouse-Hinds D 0.8 0.5 0.3 0.2 0.15 0.11 E 0.4 0.23 0.14 0.1 0.07 0.06 881 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0882-2 Name: 7L-882 7L 100: DATE: JAN 19 2006 Time: 5:58:42 PM Operator: JB COLOR: CMYK TCP: 15001 Temperature Performance Data Net Fixture Weights 150-400W FMV Series Champ® H.I.D. Luminaires Temperature Performance Data: Class 1 Lamp Watts Ambient Temp °C Non-restricted Breathing Restricted Breathing (S826TB) Division 2 Zone 2 High Pressure Sodium 150 Watt 40 55 65 250 Watt 40 55 65 400 Watt 40 55 65 Metal Halide & Pulse Start 175 Watt 40 55 65 250 Watt 40 55 65 320/400 Watt 40 55 65 Mercury Vapor 175 Watt 40 55 65 250 Watt 40 55 65 400 Watt 40 55 65 Supply Wire °C T2C T2C T2B T2 T2 325 °C T1 T1 — T6 T5 T4 T4 T4 T4 T4 T3 — 75 90 90 75 90 90 75 90 — T2 T2 325 °C T2 T2 325 °C 325 °C T1 — T4 T3 T3 T4 T3 T3 T3 T3 — 75 90 90 75 90 90 75 90 — 325 °C 325 °C 325 °C 325 °C 325 °C 325 °C 325 °C T1 — T4 T3 T3 T3 T3 T3 T3 T3 — 75 90 90 75 90 90 75 90 — US: 1-866-764-5454 CAN: 1-800-265-0502 Net Weights (lbs.) Luminaires FMVS FMVM FMVC 70-150W 37 — — 175-250W 40 42 37 400W 44 44 41 SFA6 (Slipfitter Adapter) – Add 4 lbs. SWB6 (Wall Bracket) – Add 6 lbs. 882 STIBOINFO((CRH:66008com:7L:882)) CH0 0 7 L - 9 Typedriver Name: TS name csm no.: 100 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0883-9 Name: 7L-883 100: DATE: JAN 19 2006 Time: 5:58:42 PM Operator: RB COLOR: CMYK ɀ 1000-1500W FMV ɀ High Wattage Series Champ® H.I.D. Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 Wet Locations 3, 3R 7L Application: FMV1000 Series Very High Wattage Floodlights with wet locations suitability are used outdoors: ɀ at refineries, chemical, pharmaceutical and petrochemical plants, waste and sewage treatment plants, pulp and paper mills and other industrial facilities containing hazardous (classified) areas. ɀ to light process areas, storage tank and rack areas, loading docks, rail yards, building perimeters, parking areas, vehicle and pedestrian passageways and even sports applications. ɀ for security and safety lighting in industrial and process facilities. ɀ in industrial locations where the damaging effects of rain, snow, wind, moisture, dirt, corrosion, vibration and rough usage may be a problem. ɀ to produce superior light at low cost with great efficiency. Standard Materials: ɀ Housing—Copper-free aluminum ɀ External hardware—stainless steel ɀ Yoke—Steel ɀ Lens—Heat and impact-resistant tempered glass ɀ Gasketing—neoprene Standard Finishes: ɀ Aluminum—epoxy powder coat ɀ Steel (Yoke)—hot dipped galvanized ɀ Stainless Steel—natural Ratings (Electrical/Size): Sources/Wattages (Mogul Base Lamps) ɀ High Pressure Sodium (HPS) 1000W ɀ Metal Halide (MH) 1000W & 1500W ɀ Mercury Vapor (MV) 1000W Voltages Standard Voltage Ballasts Hub Size ɀ 3⁄4⍯ NPT ɀ Furnished prewired with cord connector And 3 ft. of 14/3 SO cord Certifications and Compliances: Key Features ɀ Heavy duty copper-free aluminum housing with epoxy powder coat finish. Unique 3 piece housing design. ɀ Prewired with 3 ft. of 14/3 SO cord. ɀ Requires only two bolts to mount ɀ Easily adjustable to aim light where desired ɀ Heat and impact resistant tempered glass lens ɀ Heavy duty neoprene gasketing ɀ Anodized precision formed aluminum reflector ɀ NEMA 7x6 beam spread for light pattern ɀ Removable top plate provides easy access to lamp compartment specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Allows mounting location flexiblity, roof top, wall mount, etc. Provides exceptional stability Insures a reliable and long life environmental seal Superior beam control, distribution and efficiency. The ideal light distribution for industrial applications Minimizes maintenance. Lens removal is not required for lamp replacement. Suffix to be Added to Description Cat. No. ɀ Fusing. . . . . . . . . . . . . . . . . . . . . . . . . . S658* ɀ Slipfitter adapter (To be mounted to yoke mount luminaire) . . . . . . . . . . . . . . . SFA6 (Note: SFA6 fits onto 2⍯ pipe/conduit) ɀ Wall bracket (use with slipfitter adapter SFA6 for easy wall mounting & increased adjustability.) . . . . . . . . . . . . . SWB6 US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:883)) Provides coolest operation for increased component life Simplifies installation Options: ɀ NEC: Class I, Division 2, Groups A, B, C, D ɀ UL Standards 844 1598 Luminaires * When ordering fuses for luminaires, option S658, you must CH0 0 7 L 1 0 Benefits Superior performance, life and corrosion resistance CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 883 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0884-3 Name: 7L-884 7L DATE: JAN 19 2006 Time: 5:58:43 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Ordering Information Dimensions and Weights 1000-1500 FMV High Wattage Series Champ® H.I.D. Luminaires Dimensions: Net Luminaire Weights (lbs) Ordering Information: *To complete Catalog Number, add Voltage and Options suffix(es) Luminaire Series FMVSY1000 FMVMY1000 FMVMY1500 FMVCY1000 Weight (lbs.) 95 88 98 92 Example: FMVSY1000/480-76-S658 Lamp Type High Pressure Sodium Metal Halide Pulse Start Metal Halide Mercury Vapor Watts 1000 Base Catalog No.* FMVSY1000 -76 1000 1500 1000 FMVMY1000 -76 FMVMY1500 -76 FMVMY1000 -76 S828 1000 FMVCY1000 -76 Complete the Catalog Number by Adding Voltage and Options Suffixes as Follows: 1. Standard Voltages - Add one of the following Suffixes (For other Voltages Consult Cooper Crouse-Hinds) Voltage 120 480 MT TT Suffix /120 /480 /MT /TT 2. 884 STIBOINFO((CRH:66008com:7L:884)) CH0 7 L - 1 1 US: 1-866-764-5454 Options - Add the Required Options Suffixes from page 883, In Alpha-numeric Order CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0885-2 Name: 7L-885 100: DATE: JAN 19 2006 Time: 5:58:44 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Temperature Performance Data 1000-1500 FMV High Wattage Series Champ® H.I.D. Luminaires 7L Isofootcandle Chart FMV1000W High Pressure Sodium Catalog Number FMVSY1000-76 Lamp: 1000 watt clear high pressure sodium Lumen rating: 140,000 Isofootcandle Chart FMV1000W Metal Halide Catalog Number FMVMY1000-76 Lamp: 1000 watt clear metal halide Lumen rating: 110,000 For 1500 watt clear metal halide, multiply footcandles by 1.4. Luminaire located at 0°, 0° Aiming Angle at 45° (Note: Luminaire aiming angle limited to 45° past vertical through 60° before vertical.) Luminaire located at 0°, 0° Aiming Angle at 45° (Note: Luminaire aiming angle limited to 45° past vertical through 60° before vertical.) Footcandle Table for FMVS1000W Effective Projected Area (EPA) Mounting Height ɀ For windloading ɀ For proper pole selection Aiming Angle EPA 0° 3.5 ft2 45° 3.6 ft2 60° 2.9 ft2 20′ 25′ 30′ 35′ 40′ Footcandle Values for Isofootcandle Lines A B C 12.6 6.4 3.1 8.1 3.9 2.0 5.6 2.8 1.4 4.2 2.1 1.0 3.1 1.6 0.8 D 1.4 0.8 0.6 .42 .32 E .64 0.4 2.8 0.2 .17 Temperature Performance Data: Class 1 1000 Non-restricted Breathing Division 2 T1 Restricted Breathing Zone 2 — 1000 T1 — 40 °C 1000 T1 — 40 °C Lamp Watts HPS Metal Halide Mercury Vapor US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:885)) CH0 0 7 L - 7 CAN: 1-800-265-0502 Ambient 40 °C Copyright© 2006 Cooper Crouse-Hinds 885 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0886-2 Name: 7L-886 7L 100: DATE: JAN 19 2006 Time: 5:58:45 PM Operator: JB COLOR: CMYK TCP: 15001 F2MV, FMV, FMV1000 Series Floodlights Accessories 2.5⍯ O.D. SWB6 Wall Bracket SFA6 Slipfitter 886 STIBOINFO((CRH:66008com:7L:886)) CH0 0 7 L 1 2 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0887-15 Name: 7L-887 DATE: JAN 19 2006 Time: 5:58:46 PM Operator: RB FZD Series Floodlight Luminaire COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups C & D Cl, I, Zone I Marine Locations Wet Locations, IP66 7L Finally, a true floodlight luminaire for hazardous areas. Cooper Crouse-Hinds® FZD-Series TM Luminaires are the first to deliver NEMA 7x6 floodlight distribution patterns for Class I, Division 1 and Zone 1 environments. That means you’ll need fewer of them to illuminate a given area. With their labor-saving features and flexible mounting options, the FZD series is ideal for: ɀ heavy process industries where flammable or explosive vapors or gases are present ɀ hazardous areas, both indoors and outdoors, including those requiring elevated ambient capability, where long life and low maintenance costs are desired ɀ petroleum refineries, chemical, petrochemical and other heavyprocess industrial facilities ɀ mounting to a wall, structure or pole (with pole mount adapter accessory) FZD with separate ballest enclosure KEY FEATURES AND BENEFITS ɀ NEMA 7x6 floodlight distribution pattern is standard—ideal light distribution for industrial applications; requires fewer luminaires in general lighting applications than required when using general-area luminaires with high-bay reflectors ɀ Internal reflector—available in wide and narrow-beam options; enclosed in glass tube, reducing maintenance and enhancing light output ɀ Heavy-duty, cast copper-free aluminum construction with epoxy powder-coat finish and stainless steel hardware— provides long life in industrial, abusive environments CERTIFICATIONS AND COMPLIANCES ɀ Explosionproof threaded construction— suitable for hazardous and industrial applications; easy to maintain with no bolted covers ɀ O-ring gaskets on all threaded openings— allow NEMA Type 4X and Marine Listing for the harshest outdoor environments ɀ 40°C, 55°C and 65°C ambient suitability— ideal for use in high ambient temperature areas common in industrial facilities ɀ Factory-sealed ballast housing—keeps ballast isolated from wiring chamber ɀ Trunnion (yoke) mount design—standard construction provides the greatest mounting flexibility; can be vertically (wall) or horizontally (rooftop or floor) mounted NEC/CEC STANDARD MATERIALS ɀ Class I, Division 1, Groups B (with suffix -GB*), C and D ɀ Class I, Zone 1, Groups IIB+H2 (with suffix -GB*), IIB ɀ AEx d IIB+H2 (with suffix -GB*), IIB ɀ Ex d IIB+H2 (with suffix -GB*), IIB ɀ Marine Locations ɀ Wet Locations ɀ Enclosure Type 4X ɀ IP66 ɀ UL Listed (UL Standards 844, 1598, 1598A, 2279) ɀ cUL Listed (certified by UL to CSA Standard C22.2 No. 137 and CAN/CSA-E60079-1) ɀ luminaire housing, covers, socket holder, lamptube end rings— copper-free aluminum ɀ external hardware—stainless steel ɀ glass lamp tube—heat and impact-resistant tempered glass ɀ O-ring gaskets—neoprene/silicone ɀ yoke—aluminum ɀ trunnion adapter—brass *See options for Group B and IIB+H2 ordering information DIMENSIONS (inches) STANDARD FINISHES ɀ aluminum—Corro-free TM epoxy powder coat ɀ stainless steel—natural ɀ brass—natural LUMINAIRE WEIGHTS (lbs) LUMINAIRE 150-watt 175 to 250-watt 400-watt US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:887)) CH0 0 4 F - 5 FZDS (HPS) 72 77 80 CAN: 1-800-265-0502 FZDM (MH) 75 77 80 ɀ Simple installation—requires only two bolts to mount ɀ Mounting flexibility—pole mount with SFA6-XP pole mount adapter (shown below) or wall or ceiling mount with FZD-KIT1 mounting accessory kit (shown above). POLE MOUNT ADAPTER RATINGS SOURCES/WATTAGES (MOGUL BASE LAMPS) ɀ HPS—150, 250 & 400 watts ɀ MH—175, 250 & 400 watts VOLTAGES Standard Voltage Ballasts ɀ Multi-tap (120, 208, 240 & 277 V, 60 Hz) ɀ 120 V, 60 Hz ɀ 480 V, 60 Hz ɀ Tri-tap (120, 277 & 347 V, 60 Hz) Optional Voltage Ballasts ɀ 220 V, 60 Hz ɀ 220 V, 50 Hz HUB SIZE ɀ Standard: Two 3⁄4⍯ NPT entries ɀ Optional: Two 25 mm (M25) entries (consult Cooper Crouse-Hinds) EFFECTIVE PROJECTED AREA (EPA) ɀ For windloading ɀ For proper pole selection AIMING ANGLE 0 degrees 45 degrees Copyright© 2006 Cooper Crouse-Hinds EPA 1.8 ft2 2.3 ft2 887 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0888-19 Name: 7L-888 7L 100: DATE: JAN 19 2006 Time: 5:58:48 PM Operator: RB FZD Series Floodlight Luminaire TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups C & D Cl, I, Zone I Marine Locations Wet Locations, IP66 ORDERING INFORMATION VOLTAGE SUFFIXES To complete the catalog number, add option suffix(es) if desired. Example: FZDS2NY400W/MT-S658 CATALOG NUMBER* YOKE MOUNT WITH 3⁄4⍯ NPT HUBS LAMP TYPE WATTS WIDE-BEAM REFLECTOR—NEMA 7x6 DISTRIBUTION High-Pressure Sodium 150** FZDS2NY150W/MT 250 FZDS2NY250W/MT 400 FZDS2NY400W/MT Metal Halide 175 FZDM2NY175W/MT 250 FZDM2NY250W/MT 400 FZDM2NY400W/MT Pulse-Start Metal Halide 175 FZDM2NY175W/MT-S828 250 FZDM2NY250W/MT-S828 400 FZDM2NY400W/MT-S828 NARROW-BEAM REFLECTOR—SPOTLIGHT DISTRIBUTION High-Pressure Sodium 150** FZDS2NY150N/MT 250 FZDS2NY250N/MT 400 FZDS2NY400N/MT Metal Halide 175 FZDM2NY175N/MT 250 FZDM2NY250N/MT 400 FZDM2NY400N/MT Pulse-Start Metal Halide 175 FZDM2NY175N/MT-S828 250 FZDM2NY250N/MT-S828 400 FZDM2NY400N/MT-S828 STANDARD VOLTAGES SUFFIX OPTIONAL VOLTAGES SUFFIX Multi-tap (120, 208, 240, 277 V, 60 Hz) /MT 220 V, 50 Hz /220 50 Tri-tap (120, 277, 347 V, 60 Hz) /TT 220 V, 60 Hz /220 120 V, 60 Hz /120 480 V, 60 Hz /480 *All FZD catalog numbers shown above are with multi-tap ballasts (120, 208, 240 & 277 V, 60 Hz). The ‘‘MT’’ in the catalog number may be changed to any of the voltage suffixes listed below. **150-watt HPS luminaires are furnished with ANSI spec/S55 ballasts for 55 V lamps. FZD WITH SEPARATE BALLAST ENCLOSURE GLASS FIBER REINFORCED POLYESTER BALLAST ENCLOSURE WITH CABLE ENTRY LAMP WATTS T-CODE CATALOG TYPE NUMBER WIDE BEAM RELFECTOR – NEMA 7×6 DISTRIBUTION HPS/MH 250 T4 NOR 000 005 192 506 Metal Halide 400 T3 NOR 000 005 194 106 High Pressure Sodium 400 T3 NOR 000 005 194 006 NARROW BEAM RELFECTOR – SPOTLIGHT DISTRIBUTION HPS/MH 250 T4 NOR 000 005 192 505 Metal Halide 400 T3 NOR 000 005 194 105 High Pressure Sodium 400 T3 NOR 000 005 194 005 SUFFIX TO ADD TO CAT.NO. Ballast-Gard TM starter cut-out switch prevents starter -BG pulsing when lamp is cycling or inoperative. Prolongs ballast and igniter life. HPS only. Not available with IR option. Factory Assembled with HID lamp installed for -FA additional labor savings. Factory Certified: Class I, Division 1, Group B and -GB Class I, Zone 1, Group IIB+H2 Instant Restrike enables a hot HPS lamp to -IR immediately restrike after a momentary loss of arc due to voltage fluctuation or power outage. It has no effect on the warm-up period of cold lamps. Available for use with 150-watt HPS only. Fusing protects ballast and capacitor against -S658* abnormal line conditions. OPTIONS ACCESSORIES (order separately) FOR POLE MOUNTING Pole mount adapter ɀ Class I, Division 1, Groups B, C and D ɀ Attach to yoke; fits 2⍯ NPT conduit pole Flexible explosionproof coupling Elbow fitting WIDE BEAM RELFECTOR – NEMA 7×6 DISTRIBUTION HPS/MH 250 T4 NOR 000 005 192 502 Metal Halide 400 T3 NOR 000 005 194 102 High Pressure Sodium 400 T3 NOR 000 005 194 002 NARROW BEAM RELFECTOR – SPOTLIGHT DISTRIBUTION HPS/MH 250 T4 NOR 000 005 192 501 Metal Halide 400 T3 NOR 000 005 194 101 High Pressure Sodium 400 T3 NOR 000 005 194 001 STIBOINFO((CRH:66008com:7L:888)) CAN: 1-800-265-0502 ECLK236 EL296-SA TEMPERATURE PERFORMANCE DATA 250-watt HPS 400-watt HPS 175-watt Metal Halide 400-watt Metal Halide US: 1-866-764-5454 SFA6-XP S658 cannot be ordered with /MT in the catalog number. 250-watt Metal Halide 888 CATALOG NO. FOR WALL OR CEILING MOUNTING Kit includes: EABC26-SA conduit outlet box, ECLK236 flexible explosionproof coupling, and EL296-SA elbow fitting. FZD-KIT1 * When ordering fuses for luminaires, option S658, you must specify the operating voltage. LAMP 150-watt HPS STAINLESS STEEL BALLAST ENCLOSURE WITH CABLE ENTRY CH0 0 4 F - 5 COLOR: CMYK AMBIENT TEMP °C 40 55 65 40 55 65 40 55 65 40 55 65 40 55 65 40 55 65 Copyright© 2006 Cooper Crouse-Hinds CLASS I, DIVISION 1, ZONE 1 T3C T3C T3B T3C T3C T3B T3C T3C T3B T3A T3 T3 T3A T3 T3 T3A T3 T3 SUPPLY WIRE °C 75 75 90 75 75 90 75 75 90 75 75 90 75 75 90 75 75 90 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0889-4 Name: 7L-889 DATE: JAN 19 2006 Time: 5:58:49 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data FZD Series Floodlight Luminaire 7L PHOTOMETRICS Note: There are no aiming angle limitations for the FZD. The only limitations are those encountered by interference of the trunnion arm. The trunnion arm may be mounted on vertical or horizontal surfaces to overcome any limitations. HPS Narrow Beam Reflector HPS Wide Beam Reflector ISO FOOTCANDLE CHART FZD 400 W High Pressure Sodium (HPS) Catalog Number FZDS2NY400N Lamp: 400 W Clear HPS Lumen rating: 50,000 Luminaire located at 0°,0°Aiming Angle at 45°down from horizontal For 150 W HPS, multiply footcandles by 0.32. For 250 W HPS, multiply footcandles by 0.6. MOUNTING HEIGHT 10′ 12′ 16′ 20′ 25′ A 200.00 138.89 78.13 50.00 32.00 FOOTCANDLE VALUES FOR ISO FOOTCANDLE LINES B C D E F 100.00 50.00 20.00 10.00 5.00 69.44 34.72 13.89 6.94 3.47 39.06 19.53 7.81 3.91 1.95 25.00 12.50 5.00 2.50 1.25 16.00 8.00 3.20 1.60 0.8 ISO FOOTCANDLE CHART FZD 400 W High Pressure Sodium (HPS) Catalog Number FZDS2NY400W Lamp: 400 W Clear HPS Lumen rating: 50,000 Luminaire located at 0°,0°Aiming Angle at 45°down from horizontal For 150 W HPS, multiply footcandles by 0.32. For 250 W HPS, multiply footcandles by 0.6. MOUNTING HEIGHT G 2.00 1.39 0.78 0.50 0.32 MH Narrow Beam Reflector A 20.00 13.89 7.81 5.00 3.20 10′ 12′ 16′ 20′ 25′ FOOTCANDLE VALUES FOR ISO FOOTCANDLE LINES B C D E 10.00 5.00 2.00 1.00 6.94 3.47 1.39 0.69 3.91 1.95 0.78 0.39 2.50 1.25 0.50 0.25 1.60 0.80 0.32 0.16 MH Wide Beam Reflector ISO FOOTCANDLE CHART FZD 400 W Metal Halide (MH) Catalog Number FZDM2NY400N Lamp: 400 W Clear MH Lumen rating: 34,000 Luminaire located at 0°,0°Aiming Angle at 45°down from horizontal For 175 W MH, multiply footcandles by 0.38. For 250 W MH, multiply footcandles by 0.6. MOUNTING HEIGHT 10′ 12′ 16′ 20′ 25′ FOOTCANDLE VALUES FOR ISO FOOTCANDLE LINES A B C D E F 100.00 50.00 20.00 10.00 5.00 2.00 64.99 34.72 13.89 6.94 3.47 1.39 39.06 19.53 7.81 3.91 1.95 0.78 25.00 12.50 5.00 2.50 1.25 0.50 16.00 8.00 3.20 1.60 0.80 0.32 US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:889)) CH0 0 4 F - 5 F 0.50 0.35 0.20 0.13 0.08 G 1.00 0.69 0.39 0.25 0.16 ISO FOOTCANDLE CHART FZD 400 W Metal Halide (MH) Catalog Number FZDM2NY400W Lamp: 400 W Clear MH Lumen rating: 34,000 Luminaire located at 0°,0°Aiming Angle at 45°down from horizontal For 175 W MH, multiply footcandles by 0.38. For 250 W MH, multiply footcandles by 0.6. MOUNTING HEIGHT A 10′ 12′ 16′ 20′ 25′ CAN: 1-800-265-0502 B 20.00 13.89 7.81 5.00 3.20 FOOTCANDLE VALUES FOR ISO FOOTCANDLE LINES C D E F 10.00 5.00 2.00 1.00 6.49 3.47 1.39 0.69 3.91 1.95 0.78 0.39 2.50 1.25 0.50 0.25 1.60 0.80 0.32 0.16 Copyright© 2006 Cooper Crouse-Hinds 0.50 0.35 0.20 0.13 0.08 889 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0890-4 Name: 7L-890 7L 100: DATE: JAN 19 2006 Time: 5:58:50 PM Operator: JB Hazard ȿ Gard® H.I.D. Floodlights Hazard ȿ Gard luminaires with Trunnion Arm (S812 suffix) and EV912 high bay reflector are used in: ɀ heavy process industries where flammable or explosive vapors or gases are present ɀ hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired ɀ petroleum refineries, chemical, petrochemical and other heavy process industry facilities ɀ hazardous locations requiring elevated ambient capability ɀ for mounting to a wall or structure ɀ mounted on a pole, when used with the SFA6 slipfitter adapter ɀ Luminaire is factory wired; power is fed through ‘‘wireless’’ connection block which serves as a mechanical seal between conduit and ballast compartments, eliminating the need for an external, field installed seal. The result is fast, easy installation. ɀ High bay reflectors of Alzak® aluminum ɀ Internally fluted glass globes reduce glare and provide comfortable viewing light. ɀ Wide range of light sources and wattages to meet specific lighting needs – 50, 70, 100, 150, 200, 250 and 400W high pressure sodium (HPS); 100, 175, 250 and 400W mercury vapor (MV); 70, 100, 175, 250 and 400W metal halide (MH). ɀ High power factor (90%+) ballasts reduce power costs – allow more luminaires per circuit. ɀ Elevated ambient capability permits reliable operation at high ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65°C. ɀ Integral ballasts – separate ballasts are not required. Lowest installed cost. ɀ Factory sealed, porcelain, mogul base socket. ɀ the trunion arm gives you the ability to offer a Hazard ȿ Gard floodlight with varying degrees of adjustability between –90° and +90°. ɀ when mounting on a wall, there are numerous mounting arrangements – due to the pre-drilled openings in the wall bracket. Size Ranges: 3⁄4⍯ Electrical Rating Ranges: ɀ 120, 208, 240, 277, 347, 480, 600, multi-tap#. ɀ 50 to 400 watts Certifications and Compliances: ɀ NEC/CEC Class I, Division 1 and 2, Groups B (with GB suffix), C, D ɀ UL Standard: 844, 595 ɀ CSA Standard: C22.2 No. 137 ɀ Catalog number includes Guard, Trunnion Arm and High Bay Reflector Luminaire Cat. No. NOTE: Replace ‘‘volts’’ with Suffix from Voltage Suffix Table below HIGH PRESSURE SODIUM EVMA42051/volts S812 EV3912 EVMA42071/volts S812 EV3912 EVMA42101/volts S812 EV3912 EVMA42151/volts S812 EV3912 EVMA42201/volts S812 EV3912 EVMA42251/volts S812 EV3912 EVMA42401/volts S812 EV3912 MERCURY VAPOR EVMA82101/volts S812 EV3912 EVMA82171/volts S812 EV3912 EVMA82251/volts S812 EV3912 EVMA82401/volts S812 EV3912 METAL HALIDE EVMA92071/volts S812 EV3912 EVMA92101/volts S812 EV3912 EVMA92171/volts S812 EV3912 EVMA92251/volts S812 EV3912 EVMA92401/volts S812 EV3912 Standard Materials: ɀ Mounting module, cover, ballast housing, guard, globe ring – copper-free aluminum ɀ Globe – heat and impact resistant glass ɀ Exterior hardware – stainless steel ɀ Lamp socket – porcelain with stainless steel screw shell ɀ Reflector – high bay: Alzak aluminum Standard Finishes: ɀ Copper-free aluminum – epoxy powder coat ɀ Alzak – natural (anodized) Options: Suffix to be Added to Description Cat. No. ɀ Fused . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S658 ɀ BallastɀGard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BG ɀ 50-400 HPS only ɀ Instant Restrike. . . . . . . . . . . . . . . . . . . . . . . . . . . . . IR ɀ Cannot be used with BG or QTZ options ɀ 50-150W LX HPS only ɀ Quartz Auxiliary Lighting. . . . . . . . . . . . . . . . . . . QTZ ɀ Not available with 400W MH or MV ɀ Uses 100 watt single ended lamp ɀ Lamp not included ɀ Group B Suitability . . . . . . . . . . . . . . . . . . . . . . . . . GB Hub Size 3⁄4 STIBOINFO((CRH:66008com:7L:890)) Watts Hub Size 50 70 100 150 3⁄4 3⁄4 3⁄4 3⁄4 3⁄4 3⁄4 3⁄4 100 175 250 400 3⁄4 70 100 175 250 400 3⁄4 3⁄4 3⁄4 3⁄4 3⁄4 3⁄4 3⁄4 3⁄4 Temperature Performance Data Hazard ȿ Gard Luminaire with Trunnion Arm (S812 suffix) Maximum Ambient Class I Watts 40°C 55°C High Pressure Sodium 50 T4 T4 70 T4 T4 100 T4 T4 150 T4 T4 200 T3A — 250 T3A — 400 T3A — Mercury Vapor 100 T3 T3 175 T3 T3 250 T3 T3 400 T2D — Metal Halide 70 T3 T3 100 T3 T3 175 T3 T3 250 T3 T3 400 T2D — T3C T3C T3C T3C — — — — — — — — — — — — Alzak is a registered trademark of ALCOA # CSA Certified luminaires are not available with multi-tap ballast or S658 fuse option. Cat. # EABC26 ECGJH Flexible Length 30 UNL 90° Angle US: 1-866-764-5454 65°C NOTE: See Section 4L for additional luminaire information. EABC Size 3⁄4 to 3⁄4 CH0 0 7 L 1 5 Typedriver Name: TS name csm no.: 100 Ordering Information Features: 890 TCP: 15001 Cl. I, Div. 1 & 2, Groups C & D Cl. I, Div. 1 & 2, Groups B, C, D (Add suffix GB) Cl. I, Zone 1 Marine Locations, IP66 Wet Locations Factory Sealed Application: COLOR: CMYK Cat. # UNL205 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Size 3⁄4 Cat. # ECGJH230 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0891-2 Name: 7L-891 100: DATE: JAN 19 2006 Time: 5:58:51 PM Operator: JB Incandescent Floodlights Application: Standard Materials: RCDE incandescent lighting luminaires are permanently installed to provide general illumination in locations having hazardous atmospheres, such as: ɀ oil refineries ɀ oil and gasoline loading docks ɀ aircraft servicing docks and shelters ɀ distilleries ɀ paint manufacturing plants ɀ pumping stations ɀ other Class I, Groups C and D locations Body – copper-free aluminum; Lens – glass, heat and impact resistant RCDE incandescent lighting luminaires have fixed mountings as follows: ɀ RCDE-6 – junction box base with four mounting feet or 2⍯ threaded hub (fill sealing chamber with Chico® A after conductors are in place) ɀ RCDE-6 adjustment allows rotation of 360° horizontally and 75° vertically. ɀ Locking screws hold housing firmly in position ɀ RCDE-10 – junction box base with four mounting feet ɀ door which threads into housing includes heat and impact-resistant lens. Door has notches or holes provided for ease of removing or tightening ɀ factory wired leads through explosion-proof seal to junction box ɀ adjustment that allows rotation of 360° horizontally and 135° vertically. Locking bolts or clamps hold housing firmly in position TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 and 2, Groups C,D Cl. I, Zone 1 RCDE Series Features: COLOR: CMYK 7L Standard Finishes: ɀ Natural Size Ranges: ɀ RCDE – Fixed mounting – 3⁄4⍯ hubs Capacity Ranges: ɀ RCDE-6 – 150 watt, PAR38 or R40; 300 watt, R40 (medium base) ɀ RCDE-10 – 500 watt, PAR64 (Ext. Mog End Prong) Certifications and Compliances: ɀ NEC/CEC: RCDE – Class I, Division 1 and 2, Groups C,D Class I, Zone 1 (see photometric data listing) ɀ UL Standard: 844 ɀ CSA Standard: C22.2 No. 137 (RCDE6 only) Note: CEC/CSA Certified RCDE6- Cooper Crouse-Hinds Canada luminaires only. RCDE-10 RCDE-6 Description Junction box base (2⍯ threaded hub) Junction box base (4 mtg. feet) Cat. # 44978A Description Junction box base (4 mtg. feet) Cat. # 47282A 44719B Ordering Information: After identifying the hazardous area, select the model of lighting luminaire required for that area. Then from the photometric data, select appropriate Cat. No. based on type of mounting desired. Example: RCDE-10 No. 47282 Temperature Performance Data (based on 40°C Ambient) 150W RCDE-6 T3B RCDE-10 300W T2B 500W T3C US: 1-866-764-5454 STIBOINFO((CRH:66008com:7L:891)) CH0 0 7 L 1 6 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 891 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0892-2 Name: 7L-892 7L DATE: JAN 19 2006 Time: 5:59:55 PM Operator: JB COLOR: CMYK TCP: 15001 Dimensions & Weights Photometric Data Cl. I, Div. 1 and 2, Group D Explosionproof RCDE Series Incandescent Floodlights Dimensions (inches) Dimensions RCDE-10 RCDE-6 Fixture Weights RCDE-6 Cat. # 44719B 44978A RCDE-10 Lbs. (Net) 21.0 21.0 Lbs. (Net) 26.0 Cat. # 47282A RCDE Photometric Data Lamp Watts and Type Location 150 Watt PAR38 Flood 150 Watt PAR38 Spot Class I Groups C,D 300 Watt* R40 Flood 300 Watt R40 Spot Class I Group D 500 Watt, PAR64 (500 PAR64/NSP) 500 Watt, PAR64 (500 PAR64/MFL) Class I, Group D 500 Watt, PAR64 (500 PAR64/WFL) Beam Spread Hor. Vert. Beam Lumens Av. Max. Candle Power 60° 60° 1690 4000 28° 28° 1200 11500 123° 123° 3200 1950 60° 60° 3100 8900 19° 14° 3000 110000 35° 19° 3300 37000 55° 32° 3400 13000 Model RCDE-6 RCDE-10 * CSA certified fixtures are for 150 watt lamp maximum. 892 STIBOINFO((CRH:66008com:7L:892)) CH0 0 7 L 1 7 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0893-3 Name: 8L-893 100: DATE: JAN 19 2006 Time: 5:59:56 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Lighting Accessories Hazardous and Non-Hazardous 8L Description Page No. Application/Selection 894-897 Hazardous Area Hangers Adjustable Type UNR 911 Flexible Type EC Series 905 Locking Coupling COUP Series 911 Outlet Box Type EAHC/EFHC Series GUA/GUF Series CPS Series 906 909, 910 908 Outlet Box Type with Flexible Cushion EFHX Series 907 Non-Hazardous Area Fittings Conduit Clamps CHS Series 903 Non-Hazardous Area Hangers – Flexible Type Ball and Cushion ARB Series UNJ/UNJC Series 901 899, 900 Cushion – Vaportight AHG Series UNHC Series 899, 900 903 Hooks and Loops UNE, UNH, UNHC Series 902, 903 Outlet Box – Ball and Cushion AL Series 898, 900 Quick Disconnect Type FHM Series US: 1-866-764-5454 STIBOINFO((CRH:66008com:8L:893)) CH0 0 0 0 7 L CAN: 1-800-265-0502 904 Copyright© 2006 Cooper Crouse-Hinds 893 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0894-3 Name: 8L-894 8L 100: DATE: JAN 19 2006 Time: 5:59:57 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Luminaire Hangers and Accessories – For Pendant Mount Application & Selection Application: Typical Luminaire Weights: Luminaire hangers listed in this section are used for pendant suspension of incandescent, high intensity discharge and fluorescent industrial luminaires. They are especially suitable for use in locations where moisture, dust, and corrosion are a problem. Hangers for Non-Hazardous Locations: ɀ Hangers listed provide a wide variety of mounting means. Luminaires may be suspended from cast outlet boxes, stamped steel outlet boxes, or directly from the conduit system. Also offered are several styles of hook type hangers, used to suspend luminaires by means of conduit stems or support rods from span wires, horizontal conduit and luminaire loops. ɀ All hangers are flexible, permitting luminaire and supporting stem to swing freely. This feature permits luminaires to hang plumb and prevents damage to the luminaire, stem and outlet box in case of high wind or accidental impact. ɀ Hangers are constructed so that luminaires cannot be rotated, thereby eliminating wire twisting and possible damage to connections. ɀ Cushion hangers, listed for most styles, include a spring which carries the weight of the luminaire. This feature prolongs lamp life and protects the luminaire assembly from shock or vibration. ɀ All hangers are easily installed. With many, the luminaire, stem and support member can be assembled and wired at the work bench before making the final installation. With several, a quick disconnect plug and receptacle feature is either provided or can be easily arranged, to facilitate luminaire installation and removal for maintenance. Luminaire Type Weight (lbs.) Luminaire Type Incandescent: H.I.D.: VAPORGARD TM Series VDA12 11⁄2 VDA12G 4 VDA12GP 41⁄4 VDA15 11⁄4 VDA15G 3 VDA15GP 31⁄4 VDA23 11⁄2 VDA23G 4 V Series V275 23⁄4 V2759 41⁄4 EV Series EVA240 71⁄2 EVA210 73⁄4 EVA215 8 EVA220 101⁄2 EVA230 19 EVA292 18 CorroȿGard® Series NDA32 51⁄2 NDA32G 71⁄2 NDA33 51⁄2 NDA33G 81⁄4 Champ® Series AMV DMVC2A100GP DMVC2A175GP DMVC2A250GP DMVM2A175GP DMVM2A250GP DMVS2A070GP DMVS2A100GP DMVS2A150GP LMVS2A035GP LMVS2A050GP LMVS2A070GP LMVS2A100GP VMVC2A100GP VMVC2A175GP VMVC2A250GP VMVC2A250GR305 VMVC2A250GRD4 VMVC2A400GR305 VMVC2A400GRD4 VMVM2A175GP VMVM2A250GP VMVM2A250GR305 VMVM2A250GRD4 VMVM2A400GR305 VMVM2A400GRD4 VMVS2A050GP VMVS2A070GP VMVS2A100GP VMVS2A150GP VMVS2A200GP VMVS2A200GR305 VMVS2A200GRD4 VMVS2A250GP VMVS2A250GR305 VMVS2A250GRD4 VMVS2A400GP VMVS2A400GR305 VMVS2A400GRD4 Hangers for Hazardous Locations: Weight (lbs.) Luminaire Type 201⁄4 283⁄4 30 313⁄4 33 333⁄4 303⁄4 313⁄4 34 103⁄4 113⁄4 113⁄4 121⁄4 15 171⁄4 31 34 311⁄2 37 341⁄2 171⁄4 34 37 341⁄2 38 351⁄2 151⁄4 161⁄4 161⁄4 161⁄2 31 34 311⁄2 31 34 311⁄2 40 43 401⁄2 ɀ As required by NEC Article 501 and CEC Part I Section 18, rigid conduit luminaire stems longer than 12⍯ must be permanently and effectively braced or flexibility provided in the form of a fitting or flexible support. ɀ A variety of hangers is offered for both rigid conduit suspension and flexible suspension. Flexible luminaire hangers listed comply with NEC Article 501 and CEC Part I Section 18 and also permit luminaires to hang plumb. Considerations for Selection: Location: ɀ Will it be a hazardous or non-hazardous location? ɀ Will it require more stringent corrosion protection material? Lighting luminaire to be used: ɀ Some hangers can be used with a multitude of luminaires; others are specialized. ɀ Weight of luminaire is a consideration in selecting cushion hangers. 894 STIBOINFO((CRH:66008com:8L:894)) CH0 0 7 L - 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Hazard-Gard® Series EVMA50W HPS EVMA70W HPS EVMA100W HPS EVMA100W MV EVMA150W HPS (55V) EVMA150W HPS (100V) EVMA175W MV EVMA175W MH EVMA200W HPS EVMA250W HPS EVMA250W MV EVMA250W MH EVMA400W HPS EVMA400W MV EVMA400W MH Weight (lbs.) 41 41 45 39 46 45 42 43 47 47 44 44 56 50 52 Fluorescent: DMVF2A026GP DMVF2A039GP DMVFB2A026GP DMVFB2A039GP EVF22062 EVF24062 EVF22082 FVN4240 FVN4340 FVN4260 NFW4240 VFA222G EVFT (2 Lamp) EVFT (4 Lamp) FVS 191⁄4 221⁄4 191⁄2 221⁄2 57 94 52 52 54 58 21 4 191⁄2 361⁄2 12 Reflector/Refractor Type EV3912 RA64, 636 RA70, 71, 739, 725 RD64, 636 RD70, 71, 739, 725 PR2, 3, 5 R2 R5 GRD4 G241 G245 GR305, GR205 1 11⁄4 1 11⁄4 1 3 131⁄2 13 133⁄4 21⁄4 21⁄4 14 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0895-2 Name: 8L-895 100: DATE: JAN 19 2006 Time: 5:59:57 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Luminaire Hangers and Accessories – For Pendant Mount 8L Quick Selector Chart Quick Selector Chart Hanger Type Function NEC/CEC Hazardous Area Compliances Use with Mtg. Box Luminaire Weight Capacity (Ball or Plain Type) 3-48 lbs. 125 lbs. Body – Feraloy® iron alloy Nipple – malleable iron Cover – sheet steel 125 lbs. Body – copper-free aluminum Cover – steel Loop and assembly – copper-free aluminum or steel Standard Material AL Outlet box and Class I, Div. 2 hanger Any nonNone hazardous or needed Class I, Div. 2 FHM Quick disconnect between luminaire and outlet box Not applicable Any nonhazardous AHG Gasketed hanger (vaportight) Class I, Div. 2; Class II, Div. 2; Class III Wet locations NEMA 3, 3R Any nonAny hazardous or Div. 2 luminaires 4-30 lbs. — Housing – malleable iron and Feraloy iron alloy Stem support – Feraloy iron alloy UNJ/UNJC Ball and cushion hanger Class I, Div. 2 Any nonAny hazardous or Class I, Div. 2 6-48 lbs. 125 lbs. Body – malleable iron Clamp – copper-free aluminum ARB Ball or cushion Class I, Div. 2 hanger Any nonGRF hazardous or Class I, Div. 2 4-30 lbs. 125 lbs. Body – Feraloy iron alloy UNE, UNH, UNHC Quick disconnect hanger hook Class I, Div. 2 Any nonNot hazardous or applicable Class I, Div. 2 12-64 lbs. 125 lbs. Malleable iron, copperfree aluminum EC Explosionproof flexible hanger Cl. I, Groups A, B, C, D; Any Cl. II, Groups E, F, G; hazardous Cl. III Any — — Body – bronze hose Fittings – steel GUA, GUJ, GUF Explosionproof boxes and hanger covers Cl. I, Groups C, D; Cl. II, Groups E, F, G; Cl. III Any hazardous None needed — 125 lbs. Boxes – Feraloy iron alloy Cover – copper-free aluminum EAHC, EFHC Explosionproof hanger Cl. I, Groups A, B, C, D; Any Cl. II, Groups E, F, G; hazardous Cl. III None needed — 125 lbs. Body – Feraloy iron alloy Cover – copper-free aluminum UNR Explosionproof adjustable hanger Cl. I, Groups C, D; Cl. II, Groups E, F, G; Cl. III Any Any hazardous or nonhazardous — 125 lbs. Feraloy iron alloy EFH Explosionproof boxes and hangers Cl. I, Groups C, D; Cl. II, Groups E, F, G; Cl. III Any hazardous 65 lbs. — Feraloy iron alloy US: 1-866-764-5454 STIBOINFO((CRH:66008com:8L:895)) CH0 0 7 L - 1 Use with Luminaire Type Luminaire Weight Capacity (Cushion) None needed None needed CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 895 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0896-2 Name: 8L-896 8L 100: DATE: JAN 19 2006 Time: 6:00:01 PM Operator: JB COLOR: CMYK TCP: 15001 Luminaire Hangers and Accessories – For Pendant Mount Typical Installations 896 STIBOINFO((CRH:66008com:8L:896)) CH0 0 7 L - 2 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0897-2 Name: 8L-897 DATE: JAN 19 2006 Time: 6:00:03 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Luminaire Hangers and Accessories – For Pendant Mount 8L Typical Installations GUFX ECHF US: 1-866-764-5454 STIBOINFO((CRH:66008com:8L:897)) CH0 0 7 L - 3 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 897 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0898-3 Name: 8L-898 8L 100: DATE: JAN 19 2006 Time: 6:00:04 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Class I, Div. 2, Groups A, B, C, D AL Flexible Luminaire Hangers For Pendant Mount Features: Functions as both conduit outlet box and luminaire hanger. Hubs are provided for threading the conduit directly into the hanger body. For use with incandescent, H.I.D. and fluorescent luminaires. ɀ Supporting nipple, ball or cushion type, is a universal joint permitting luminaire to swing through an angle of 20 degrees in any direction from the perpendicular. ɀ Cover has one screw hole and one open slot – easily swung aside for wiring without removal and possible loss of cover. ɀ Luminaire, conduit stem and nipple can be assembled and wired at the work bench. The assembly is then placed in the hanger body and luminaire wires spliced to the circuit wires. ɀ Provided with a separate grounding wire for ground connections. Ball Ball Cushion Cushion Standard Materials: ɀ Body – Feraloy® iron alloy ɀ Nipple – malleable iron ɀ Cover – sheet steel Standard Finishes: ɀ Feraloy and malleable iron – zinc electroplate and aluminum acrylic paint ɀ Sheet steel – electrogalvanized with chromate finish Size Ranges: ɀ Conduit hubs – 3⁄4⍯ to 1⍯ ɀ Luminaire stem – 1⁄2⍯ and 3⁄4⍯ ɀ Luminaire weight – cushion type, 3 to 48 lbs.; ball type, 125 lbs. Options: ɀ The following special options are available from factory by adding suffix to Cat. No.: Suffix to be Added to Description Cat. # Suspension attachment for span wire or threaded rod. See listings . . . . . . . . . . . . . S1 Suspension Attachment ALC ALT Ball Ball Luminaire Stem Size 1⁄2 3⁄4 3⁄4 Conduit Size 3⁄4 3⁄4 1 Luminaire Stem Conduit Size Size 3⁄4 1⁄2 3⁄4 3⁄4 3⁄4 1 Cat. # ALC21 ALC22 ALC32 Cushion Cushion Luminaire Stem Size 1⁄2 3⁄4 3⁄4 Conduit Size 3⁄4 3⁄4 1 1⁄2 3⁄4 3⁄4 3⁄4 3⁄4 1 1⁄2 3⁄4 3⁄4 3⁄4 3⁄4 1 1⁄2 3⁄4 3⁄4 3⁄4 3⁄4 1 Luminaire Weight Lbs. Cat. # ALC214 3 to 6 ALC224 ALC324 6 to 12 12 to 24 24 to 48 Luminaire Stem Conduit Size Size 3⁄4 1⁄2 3⁄4 3⁄4 3⁄4 1 ALC218 ALC228 ALC328 1⁄2 3⁄4 3⁄4 3⁄4 3⁄4 1 ALC2116 ALC2216 ALC3216 1⁄2 3⁄4 3⁄4 3⁄4 3⁄4 1 ALC2132 ALC2232 ALC3232 1⁄2 3⁄4 3⁄4 3⁄4 3⁄4 1 For horizontal cable or vertical support rod AL hangers can be furnished with a loop fastened to the top of the body to provide a means for suspending luminaires from vertical support rods or horizontal span wires. The loop will take a wire or cable with a maximum diameter of 3⁄8⍯. The boss on top of the loop is tapped 3⁄8⍯-16 to accept a threaded rod. 898 STIBOINFO((CRH:66008com:8L:898)) CH0 0 7 L - 4 US: 1-866-764-5454 Cat. # ALT21 ALT22 ALT32 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Luminaire Weight Lbs. Cat. # ALT214 3 to 6 ALT224 ALT324 6 to 12 12 to 24 24 to 48 ALT218 ALT228 ALT328 ALT2116 ALT2216 ALT3216 ALT2132 ALT2232 ALT3232 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0899-3 Name: 8L-899 100: DATE: JAN 19 2006 Time: 6:00:06 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 AHG – Class I, Div. 2, Groups A, B, C, D Class II, Div. 2, F, G Class III Wet Locations NEMA 3, 3R UNJ, UNJC – Class I, Div. 2, Groups A, B, C, D AHG, UNJ and UNJC Flexible Luminaire Hangers For Pendant Mount 8L Features: ɀ For connection to conduit hub or hub cover of supporting conduit fitting ɀ For incandescent, H.I.D., and fluorescent luminaires ɀ Cushion support for conduit stem is a universal joint permitting luminaire to swing through an angle of 8 degrees in any direction from the perpendicular ɀ Gasketed by means of a durable neoprene diaphragm which excludes moisture and dirt from both luminaire and conduit system Certifications and Compliances: Class I, Div. 2 Class II, Div. 2 Class III Wet Locations NEMA 3,3R Standard Materials: ɀ Housing: top cap – malleable iron; bottom cap – Feraloy® iron alloy ɀ Luminaire stem support – Feraloy iron alloy Standard Finishes: ɀ Feraloy iron alloy and malleable iron – electrogalvanized and aluminum acrylic paint Size Ranges: 3⁄4⍯ ɀ Male nipple – ɀ Luminaire stem – 3⁄4⍯ ɀ Luminaire weight – 4 to 30 lbs. AHG Cushion Vaportight for Class I, Div. 2; Class II, Div. 2; Class III Luminaire Stem Size* 3⁄4 3⁄4 3⁄4 Male Nipple Size* 3⁄4 3⁄4 3⁄4 Luminaire Weight Lbs. 4 to 8 8 to 16 16 to 30 Cat. # AHG22103 AHG22104 AHG22111 Features: ɀ For connection to conduit hub or hub cover of supporting conduit fitting ɀ For incandescent, H.I.D., and fluorescent luminaires ɀ Supporting nipple, ball or cushion type, is a universal joint permitting luminaires to swing through an angle of 20 degrees in any direction from the perpendicular Standard Materials: ɀ Body and nipple – malleable iron ɀ Clamp – copper-free aluminum Standard Finishes: ɀ Malleable iron – electrogalvanized and aluminum acrylic paint ɀ Copper-free aluminum – natural finish Size Ranges: ɀ Male nipple – 1⁄2⍯ and 3⁄4⍯ ɀ Luminaire stem – 1⁄2⍯ and 3⁄4⍯ ɀ Luminaire weight: cushion type – 6 to 48 lbs.; ball type – 125 lbs. Certifications and Compliances: UNJ Ball Luminaire Stem Size 1⁄2 3⁄4 Male Nipple Size Cat. # 1⁄2 UNJ1 3⁄4 UNJ2 ɀ NEC: Class I, Div. 2. UNJC Cushion Luminaire Stem Size* 3⁄4 3⁄4 1⁄2 3⁄4 Male Nipple Size* 3⁄4 3⁄4 1⁄2 3⁄4 Luminaire Weight Lbs. 6 to 12 12 to 24 24 to 48 Cat. # UNJC28 UNJC216 UNJC132 UNJC232 * 1⁄2⍯ connection can be made by using reducers. US: 1-866-764-5454 STIBOINFO((CRH:66008com:8L:899)) CH0 0 7 L - 6 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 899 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0900-2 Name: 8L-900 8L 100: DATE: JAN 19 2006 Time: 6:00:07 PM Operator: JB COLOR: CMYK TCP: 15001 Flexible Luminaire Hangers For Pendant Mount Dimensions AL Series UNJ UNJC Cushion Ball AHG 900 STIBOINFO((CRH:66008com:8L:900)) CH0 0 7 L - 7 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0901-3 Name: 8L-901 100: DATE: JAN 19 2006 Time: 6:00:08 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Class I, Div. 2, Groups A, B, C, D ARB and GS Flexible Luminaire Hangers 8L For Pendant Mount Features: For GRF and VXF outlet boxes only ɀ Available in two styles – one for direct attachment to GRF cast outlet boxes by 4 screws, the other for direct attachment to 4⍯ octagonal stamped steel outlet boxes by 2 screws. For incandescent, H.I.D. and fluorescent luminaires ɀ Both styles available with ball or cushion support for conduit stem to permit luminaire swing in any direction. Ball type provides 11 degree swing, cushion type 8 degree swing from the perpendicular ɀ Gasketed cushion hangers for GRF are provided with a durable neoprene diaphragm which excludes moisture and dirt from both luminaire and conduit system Outlet Boxes Ball Ball Cushion Luminaire Stem Description Size 1⁄2 Surface 1⁄2 Flush Surface 125 ɀ Mounting plate: for GRF – Feraloy® iron alloy; for 4⍯ outlet boxes – sheet steel ɀ Hanger body and luminaire stem support – Feraloy iron alloy Luminaire Weight (Max.) Cat. # 125 ARB62 125 ARB67 3⁄4 ARB662 Cushion Surface Luminaire Stem Size 1⁄2 1⁄2 1⁄2 Standard Materials: Luminaire Weight Lbs. Cat. # 4 to 8 ARB82 8 to 16 ARB102 16 to 30 ARB122 Cushion Surface – Vaportight with Neoprene Diaphragm Standard Finishes: ɀ Feraloy – electrogalvanized and aluminum acrylic paint ɀ Sheet steel – electrogalvanized with chromate finish ARB Fits GRF and VXF For GRF and VXF outlet boxes and 4⍯ octagonal outlet boxes Luminaire Stem Size 1⁄2 1⁄2 1⁄2 Luminaire Weight Lbs. Cat. # 4 to 8 ARB821 8 to 16 ARB1021 16 to 30 ARB1221 ARB Fits GRF, VXF and 4⍯ Outlet Size Ranges: Boxes Ball ɀ Luminaire stem – 1⁄2⍯ and 3⁄4⍯ ɀ Luminaire weight: cushion type – 4 to 30 lbs.; ball type – 125 lbs. (ARB6 and ARB2 maximum weight 60 lbs.) Ball Cushion Luminaire Stem Size 1⁄2 3⁄4 Luminaire Weight (Max.) 60 60 Cat. # ARB6 ARB2 Luminaire Weight Lbs. 4 to 8 8 to 16 16 to 30 Cat. # ARB8 ARB10 ARB12 Cushion Luminaire Stem Size 1⁄2 1⁄2 1⁄2 US: 1-866-764-5454 STIBOINFO((CRH:66008com:8L:901)) CH0 0 7 L - 9 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 901 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0902-2 Name: 8L-902 8L 100: DATE: JAN 19 2006 Time: 6:00:09 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. l, Div. 2 Groups A, B, C, D UNE, UNH and UNHC Flexible Luminaire Hangers For Pendant Mount The following applies to all items on this page: Application: ɀ Provides a simple, inexpensive, quick disconnect method for hanging pendant luminaires. For incandescent, H.I.D. and fluorescent luminaires ɀ Permits free swing in any direction to prevent damage to luminaire stem. Cushion style provides additional protection from vibration to prolong lamp life Features: ɀ Female hooks and loops are used with rigid conduit luminaire stems to suspend luminaires. They may also be used with male hooks and loops, threaded into a conduit outlet hub. ɀ All hooks and loops are provided with openings for passage of luminaire wires. Luminaire, conduit stem and hook or loop can be assembled and wired at the work bench. The assembly is then hung on the fixed hook and connection made. ɀ For ease of relamping and maintenance, the outlet fitting can be equipped with an attachment plug receptacle cover and a matching plug cap used with the luminaire assembly. For permanent wiring a wire hole cover may be used. Applicable to UNE and UNH (upper listings) only: Male Female Male UNH Female UNE UNE and UNH Flexible Luminaire Hangers For Pendant Mount Type Style Male Luminaire Stem Size 1⁄2 3⁄4 Luminaire Weight Lbs. 125 125 Cat. # UNH16 UNH26 125 125 UNH1 UNH2 125 125 UNE16 UNE26 125 125 UNE1 UNE2 UNH Female Male 1⁄2 3⁄4 1⁄2 3⁄4 UNE Female Features: 1⁄2 3⁄4 ɀ Shape of hooks is such that accidental disengagement is impossible ɀ Diameter of wire opening 1⁄2⍯ Standard Materials: ɀ Malleable iron Standard Finishes: ɀ Cadmium electrogalvanized and aluminum acrylic paint Size Ranges: ɀ Luminaire stem or hub – 1⁄2⍯ and 3⁄4⍯ ɀ Luminaire weight – 125 lbs. Applicable to UNH and UNHC (lower listings) only: Features: ɀ Hooks are shaped to permit easy installation of large heavy luminaires, such as H.I.D. and fluorescent units ɀ Diameter of wire opening 5⁄8⍯ Standard Materials: ɀ Copper-free aluminum Female UNH and UNHC Flexible Luminaire Hangers Type UNH Style Female UNHC Standard Finishes: Female Cushion Female Cushion Luminaire Stem Size Luminaire Weight Lbs. Cat. # 1⁄2 125 UNH182 3⁄4 12 to 24 24 to 48 48 to 64 UNHC216 UNHC232 UNHC264 3⁄4 3⁄4 ɀ Natural Size Ranges: ɀ Luminaire stem – 1⁄2⍯ and 3⁄4⍯ ɀ Luminaire weight: cushion type – 12 to 64 lbs.; plain type – 125 lbs. 902 STIBOINFO((CRH:66008com:8L:902)) CH0 7 L - 1 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0903-2 Name: 8L-903 100: DATE: JAN 19 2006 Time: 6:00:11 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 No Wireway Opening UNHC Flexible Luminaire Hangers 8L For Support Only CHS Conduit Clamp; UNH Conduit Hook; For Pendant Mount Fluorescent Luminaires Application: ɀ Used for support of pendant fluorescent luminaires ɀ UNHC provides cushion support for luminaires suspended by 1⁄4⍯ or 5⁄16⍯ threaded rod, and is used with the ring of CHS conduit clamps ɀ UNH hook provides an extremely simple means of conduit suspension for the unwired end of a fluorescent luminaire, as it merely hooks over the horizontal supporting conduit Features: ɀ The bushing in UNHC cushion hangers is tapped for both 1⁄4⍯ and 5⁄16⍯ suspension rod, with the lower half tapped 5⁄16⍯. Either size rod can be used without reversing the bushing ɀ CHS conduit clamp firmly grips the conduit and the ring at bottom accepts either a hooked rod or the UNHC cushion hanger for threaded rod. Will also accept UNH and UNHC hangers for conduit stem listed on the preceding page. ɀ The UNH conduit hook fits over conduit up to and including 1⍯ and has a hub for attachment of a 1⁄2⍯ conduit stem Clamp UNHC Cushion Luminaire Hangers Luminaire Weight Lbs. 12 to 24 24 to 48 48 to 64 Support Rod Tap 1⁄4⍯-20 and 5⁄16⍯-18 Cat. # UNHC2816 UNHC2832 UNHC2864 Hook CHS Conduit Clamp and UNH Hook Conduit Size 1⁄2 3⁄4 1 Clamp Hook Cat. # Cat. # CHS1437 CHS2437 ៑ UNH13 CHS3437 Hook Hub Size 1⁄2 Standard Materials: ɀ UNHC – copper-free aluminum ɀ CHS-body – malleable iron; clamp – copper-free aluminum; ring – steel wire ɀ UNH – Feraloy® iron alloy Standard Finishes: ɀ Copper-free aluminum – natural finish ɀ Feraloy and malleable iron – electrogalvanized and aluminum acrylic paint ɀ Steel wire – electrogalvanized with chromate finish Size Ranges: ɀ Luminaire stem (UNH) – 1⁄2⍯ ɀ Conduit (CHS): 1⁄2⍯ to 1⍯ ɀ Luminaire weight: UNHC cushion – 12 to 64 lbs.; CHS, UNH – 125 lbs. US: 1-866-764-5454 STIBOINFO((CRH:66008com:8L:903)) CH0 7 L - 1 1 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 903 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0904-2 Name: 8L-904 8L 100: DATE: JAN 19 2006 Time: 6:00:42 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 FHM Power Hook Luminaire Hangers For Pendant Luminaires Features: ɀ For mounting H.I.D. type luminaires in non-hazardous locations ɀ Power hook housing has two 3⁄4⍯ through feed hubs and one 3⁄4⍯ hub on the top for pendant mounting. Through feed hubs are furnished with flush plugs ɀ Cast mounting lugs are provided for direct ceiling mounting ɀ Housing contains a roomy 15 cu. in. splicing chamber and interlocking type receptacle with leads ɀ Plugs and receptacles are interlocking type to prevent accidental disengagement. When plug is inserted, hook is blocked and luminaire assembly cannot be removed. To service the luminaire, pull the plug, unhook the loop luminaire assembly and take it to a convenient servicing area ɀ Loop can move a maximum of 30°, allowing the power hook to be mounted on a canted ceiling. The luminaire assembly will hang true to the vertical ɀ Loop and hook are shaped for self alignment and resist twisting of luminaire by gusts of wind or light drafts ɀ Supporting loop is furnished with 16⍯ of #16-3/C type SO cord and an interlocking type plug FHM For H.I.D. Type Luminaires with voltages up to 480 volts Loop Plain Luminaire Stem* 3⁄4 Hubs* 3⁄4 Luminaire Weight Lbs. 125 Cat. # FHM201 Standard Materials: ɀ Power hook body – copper-free aluminum ɀ Access cover – zinc plated cold rolled steel ɀ Loop – copper-free aluminum Plain * 1⁄2⍯ connection can be obtained by using reducers Standard Finishes: ɀ Copper-free aluminum – natural finish ɀ Steel – electrogalvanized with chromate finish Dimensions Size Ranges: ɀ Hubs – 3⁄4⍯ ɀ Luminaire weights: loop – up to 125 lbs.; ɀ Loop luminaire stem size – 3⁄4⍯ Electrical Rating Ranges: ɀ 480 volts, 14 amps, 2 wire, 3 pole Certifications and Compliances: ɀ Meet UL and NEMA requirements for the listed electrical ratings Plain 904 STIBOINFO((CRH:66008com:8L:904)) CH0 0 7 L - 8 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0905-2 Name: 8L-905 100: DATE: JAN 19 2006 Time: 6:00:43 PM Operator: JB COLOR: CMYK Cl. I, Div. 1 & 2, Groups A, B, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III ECHF Flexible Luminaire Supports For Pendant Mount TCP: 15001 Typedriver Name: TS name csm no.: 100 Explosionproof Dust-Ignitionproof 8L Application: ECHF series flexible luminaire supports are used in hazardous locations: ɀ where a luminaire must hang more than 12⍯ from its supporting junction box (as specified by NEC Article 501 and CEC Part I Section 18) ɀ to assure that luminaires hang plumb and will swing freely if accidentally struck. Prevents damage to luminaire and supporting outlet fitting Features: ɀ Complies with NEC Article 501/CEC Part I Section 18 ɀ Free swinging in any direction through a large arc ɀ Good electrical continuity – no bonding jumpers needed ɀ Watertight construction ɀ Insulating liner of asphalt impregnated fiber to protect conductors ɀ Constructed to reinforced flexible metal hose ɀ Two female end fittings, each with a removable short nipple ɀ Nipples fit set screw type luminaire hubs ɀ Female end fittings are equipped with set screws to prevent turning during relamping and loosening of fitting with vibrations ECHF Description Flexible Nipple Length Size 1⁄2 4 3⁄4 6 8 10 12 15 18 1⁄2 3⁄4 1⁄2 3⁄4 1⁄2 3⁄4 1⁄2 3⁄4 1⁄2 3⁄4 1⁄2 3⁄4 Overall Length 10 10 Cat. # ECHF14 ECHF24 12 12 ECHF16 ECHF26 14 14 ECHF18 ECHF28 16 16 ECHF110 ECHF210 18 18 ECHF112 ECHF212 21 21 ECHF115 ECHF215 24 24 ECHF118 ECHF218 Standard Materials: ɀ Inner core – brass ɀ Outer braid – bronze ɀ End fittings – bronze ɀ End fittings – brass (CSA certified units) Standard Finishes: ɀ Brass and bronze – natural Options: Suffix to be Added to Description Cat. # Material – stainless steel hose and end fittings . . . . . . . . . . . . . . . . . . . . . . . . . . S516 Finish – flexible neoprene protective coating. . . . . . . . . . . . . . . . . . . . S758 Special lengths and sizes available . . . . . . . . . . . . . . Detailed information on request Size Ranges: ɀ Flexible length – 4⍯ to 18⍯ ɀ Nipple size – 1⁄2⍯ and 3⁄4⍯ (see ‘‘Options’’) ɀ Luminaire weight – up to 125 lbs. Certifications and Compliances: ɀ NEC/CEC: Class I, Groups A, B, C, D Class II, Groups E, F, G Class III ɀ UL Standard: 886 ɀ CSA Standard: C22.2 No. 30 US: 1-866-764-5454 STIBOINFO((CRH:66008com:8L:905)) CH0 7 L - 1 2 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 905 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0906-2 Name: 8L-906 8L 100: DATE: JAN 19 2006 Time: 6:00:44 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups A*, B*, C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III EAHC and EFHC Luminaire Hangers For Pendant Mount Explosionproof Dust-Ignitionproof Application: EAHC and EFHC luminaire hangers are for use in hazardous areas to: ɀ suspend explosionproof pendant luminaires from the conduit system ɀ function as both conduit outlet box and luminaire hanger Mounting Strap Mounting strap can be furnished to fasten luminaire hangers to mounting surface, independent of conduit straps. To order, add suffix S294 to EAHC or EFHC Cat. No. Features: ɀ Through feed hubs are provided for threading the conduit directly into the hanger body ɀ Has large threaded cover for accessibility and ease of wiring ɀ Bottom hub, threaded or union style, is equipped with set screws to securely lock luminaire stem in place. Takes conduit stem or EC flexible luminaire hanger for stems longer than 12⍯ (in compliance with NEC Article 501 and CEC Part I Section 18) With union hub Suspension Attachment Standard Materials: ɀ Bodies – Feraloy® iron alloy ɀ Covers – copper-free aluminum With threaded hub Standard Finishes: ɀ Feraloy – electrogalvanized and aluminum acrylic paint ɀ Copper-free aluminum – natural Options: Suffix to be Added to Description Cat. # Finish – Corro-free TM epoxy enamel . . . . S752 Suspension attachment for span wire or threaded rod – see listings . . . . . . . . S1 Mounting strap – see listings . . . . . . . . . . S294 Size Ranges: ɀ Conduit hubs – 3⁄4⍯ and 1⍯ ɀ Luminaire stem – 1⁄2⍯ and 3⁄4⍯ ɀ Luminaire weight – 125 lbs. EAHC and EFHC hangers can be furnished with a loop fastened to the top of the body to suspend luminaire and conduit from vertical support rods or horizontal span wires. The loop will take a wire or cable with a maximum diameter of 3⁄8⍯. The boss on top of the loop is tapped 3⁄8⍯-16 to accept a threaded rod. To order, add suffix S1 to Cat. No. EAHC* Luminaire Hub Stem Size Size 1⁄2 3⁄4 3⁄4 1⁄2 1 3⁄4 Threaded Hub for Luminaire Stem Cat. # EAHC2701 EAHC2702 EAHC3701 EAHC3702 Union Hub for Luminaire Stem Cat. # EAHC2601 EAHC2602 EAHC3601 EAHC3602 EFHC2701 EFHC2702 EFHC3701 EFHC3702 EFHC2601 EFHC2602 EFHC3601 EFHC3602 EFHC 3⁄4 1 1⁄2 3⁄4 1⁄2 3⁄4 *EAHC only Certifications and Compliances: ɀ NEC/CEC: EAHC – Class I, Groups A, B, C, D Class II, Groups E, F, G Class III EFHC – Class I, Groups C, D Class II, Groups E, F, G Class III ɀ UL Standard: 886 ɀ CSA Standard: C22.2 No. 30 906 STIBOINFO((CRH:66008com:8L:906)) CH0 7 L - 1 5 Dimensions US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0907-2 Name: 8L-907 DATE: JAN 19 2006 Time: 6:00:45 PM Operator: JB COLOR: CMYK Cl. I, Div. 1 and 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III EFH Flexible Cushion Luminaire Hangers For Pendant Mount TCP: 15001 Typedriver Name: TS name csm no.: 100 Explosionproof Dust-Ignitionproof 8L Application: EFH flexible cushion luminaire hangers are used in hazardous locations: ɀ where a luminaire must hang more than 12⍯ from its supporting junction box (as required by NEC Article 501 and CEC Part I Section 18) ɀ to assure that luminaires hang plumb and will swing freely if accidentally struck. Prevents damage to luminaire, stem and supporting outlet box ɀ to provide a cushion support, prolonging lamp life and protecting the luminaire from shock and vibration. For luminaires weighing up to 65 lbs. Features: ɀ Complies with NEC Article 501 and CEC Part I Section 18 ɀ Free swinging in any direction through an angle of 15 degrees from perpendicular ɀ Weight of luminaire is supported by a high-strength brass bellows and a stainless steel cushioning spring ɀ Two part assembly consisting of luminaire hanger cover and CPS12 outlet box. Provides a wide variety of conduit arrangements. A set screw locks the conduit stem in place Standard Materials: ɀ Feraloy® iron alloy Standard Finishes: ɀ Electrogalvanized and aluminum acrylic paint Size Ranges: ɀ Conduit hubs – 3⁄4⍯ with 3⁄4⍯ to 1⁄2⍯ reducers ɀ Luminaire stem – 1⁄2⍯ and 3⁄4⍯ ɀ Luminaire weight – 65 lbs. max. EFHX Body Hub Size‡ 1⁄2 1⁄2 Luminaire Stem Size 1⁄2 and 3⁄4 and 3⁄4 3⁄4 With Mtg. Feet Cat. # EFHX111 EFHX221 Cushion Luminaire Hanger Only Stem Size 1⁄2 3⁄4 Cat. # EFH01 EFH02 ‡ Furnished with four 3⁄4⍯ standard taper tapped, integrally bushed hubs. Each hub as a 3⁄4⍯ to 1⁄2⍯ reducer. Three hubs are plugged. Dimensions Certifications and Compliances: ɀ NEC/CEC: Class I, Groups C, D Class II, Groups E, F, G Class III ɀ UL Standard: 886 ɀ CSA Standard: C22.2 No. 30 US: 1-866-764-5454 STIBOINFO((CRH:66008com:8L:907)) CH0 7 L - 1 7 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 907 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0908-2 Name: 8L-908 100: DATE: JAN 19 2006 Time: 6:00:46 PM Operator: JB Condulet® Conduit Outlet Boxes with Covers 8L COLOR: CMYK TCP: 15001 Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III Typedriver Name: TS name csm no.: 100 Explosionproof Dust-Ignitionproof Application: CPS series conduit outlet boxes are installed in conduit systems in hazardous areas to: ɀ protect conductors in threaded rigid conduit ɀ act as pull and splice boxes ɀ change conduit direction ɀ interconnect lengths of conduit ɀ act as luminaire hangers with hub covers ɀ provide access to conductors for maintenance and future system changes Features: CPS conduit outlet boxes have: ɀ two types of cover: – blank for splice or pull box use – threaded hub for mounting luminaires ɀ wide, accurately machined body and cover mating surfaces, to insure flametight joint ɀ blind tapped holes for cover screws to further insure flametightness ɀ removable mounting feet for flush or surface mounting to wall or ceiling Standard Materials: ɀ Feraloy iron alloy ® Standard Finishes: Box with Hub Cover Box with Blank Cover Hub Size Hub Size 1⁄2 and 3⁄4 Body‡ 1⁄2 and 3⁄4 1⁄2 and 3⁄4 Cover 1⁄2 3⁄4 Cat. # CPS12021 CPS12022 Hub Covers Hub Size 1⁄2 3⁄4 Body Hub Size‡ 1⁄2 and 3⁄4 ‡ Furnished with four 3⁄4⍯ standard taper tapped, integrally bushed hubs. Options: ɀ Corro-free epoxy powder coat . . . . . . . . . . . . . . . . . . . . Information available on request Cat. # CPS021 CPS022 Cat. # CPS12 ɀ Electrogalvanized and aluminum acrylic paint TM Cat. # CPS12026 Each hub has a 3⁄4⍯ to 1⁄2⍯ reducer. Three hubs are plugged. Dimensions Certifications and Compliances: ɀ NEC/CEC: Class I, Groups C, D Class II, Groups E, F, G Class III ɀ UL Standard: 886 ɀ CSA Standard: C22.2 No. 30 908 STIBOINFO((CRH:66008com:8L:908)) CH0 7 L - 1 8 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0909-2 Name: 8L-909 DATE: JAN 19 2006 Time: 6:00:47 PM Operator: JB COLOR: CMYK Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III GUF Outlet Bodies and Luminaire Hanger Covers TCP: 15001 Typedriver Name: TS name csm no.: 100 Explosionproof Dust-Ignitionproof 8L Luminaire Hanger Covers For GUA and GUF Series Junction Boxes Nom. Dia. Luminaire Luminaire Luminaire covers Nipple covers Cover Stem canopies union hub Opening Size Cat. # Cat. # Cat. # 3⁄4 GUA068 GUA0687 GUA0672 3 GUFX Hub Size 1⁄2 3⁄4 Cat. # GUFX160 GUFX260 Dimensions Hanger Covers Dimensions GUF Series GUA 068 GUA 0687 Hub Size 1⁄2 3⁄4 1 a 31⁄2 31⁄2 31⁄2 b 2 2 23⁄8 c 3 3 3 d e f 5⁄8 7⁄8 5⁄16 3⁄4 7⁄8 1 5⁄16 5⁄16 7⁄8 g 53⁄8 53⁄8 53⁄8 GUA 0671 US: 1-866-764-5454 STIBOINFO((CRH:66008com:8L:909)) CH0 7 L - 1 4 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 909 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0910-2 Name: 8L-910 8L 100: DATE: JAN 19 2006 Time: 6:00:49 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III GUA Series Outlet Bodies Explosionproof Dust-Ignitionproof Application: GUA, GUF and GUJ outlet bodies are used: ɀ with luminaire canopies, union hub and nipple covers for mounting EVA, EVM, EVLP, and EVF luminaires Features: ɀ A threaded cover opening in the side of the canopy permits access to the interior for making splices or taps ɀ The luminaire with its conduit stem and canopy is wired before installation, which eliminates wire twisting when the canopy is screwed into the outlet body ɀ Union hub covers permits the cover to be screwed into the body without twisting wire leads ɀ All covers have set screws to lock the conduit stem or EC series flexible luminaire support firmly to the cover GUA Hub Size 1⁄2 3⁄4 1 GUAT Cat. # GUA160 GUA260 GUA360 Hub Size 1⁄2 3⁄4 1 Cat. # GUAT160 GUAT260 GUAT360 Standard Materials: Outlet bodies: ɀ GUA Series – Feraloy iron alloy ɀ GUFX – Copper-free aluminum Luminaire hanger covers: ɀ GUA068 – Feraloy iron alloy ɀ GUA0687, GUA0672 – Copper-free aluminum Standard Finishes: ɀ Feraloy iron alloy – electrogalvanized and aluminum acrylic paint ɀ Copper-free aluminum – natural GUAC Hub Size 1⁄2 3⁄4 1 Cat. # GUAC160 GUAC260 GUAC360 GUAX Hub Size 1⁄2 3⁄4 1 Options: Suffix to be Added to Description Cat. # Finish – Corro-free TM epoxy enamel . . . . S752 Cat. # GUAX160 GUAX260 GUAX360 Size Ranges: ɀ Bodies – 1⁄2⍯ to 1⍯ hubs ɀ Canopies – 1⁄2⍯, 3⁄4⍯ and 11⁄4⍯ luminaire stem ɀ Union hub and nipple covers – 1⁄2⍯ and 3⁄4⍯ luminaire stem Certifications and Compliances: ɀ NEC/CEC: Class I, Groups C, D Class II, Groups E, F, G Class III ɀ UL Standard: 886 ɀ CSA Standard: C22.2 No. 30 GUAL Hub Size 1⁄2 3⁄4 1 Cat. # GUAL160 GUAL260 GUAL360 Dimensions GUA Series Hub Size 1⁄2 3⁄4 1 910 STIBOINFO((CRH:66008com:8L:910)) CH0 7 L - 1 3 US: 1-866-764-5454 CAN: 1-800-265-0502 a 31⁄2 31⁄2 31⁄2 b 2 2 25⁄16 c 3 3 3 Copyright© 2006 Cooper Crouse-Hinds d 5⁄8 3⁄4 7⁄8 e 7⁄8 7⁄8 1 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0911-2 Name: 8L-911 100: DATE: JAN 19 2006 Time: 6:01:22 PM Operator: JB COLOR: CMYK TCP: 15001 Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III UNR Adjustable Luminaire Hangers; COUP Locking Couplings Typedriver Name: TS name csm no.: 100 Explosionproof Dust-Ignitionproof 8L For Pendant Mount Application: Standard Finishes: UNR adjustable luminaire hangers are used in hazardous areas to: ɀ mount between a luminaire and its outlet box so that the luminaire can be adjusted within the range of 0 degrees to 90 degrees ɀ permit pendant type luminaires to illuminate vertical surfaces such as a control board ɀ hang luminaires plumb when the supporting outlet box is not horizontal ɀ Electrogalvanized and aluminum acrylic paint Features: ɀ NEC: Class I, Groups C, D Class II, Groups E, F, G Class III ɀ UL Standard: 886 The luminaire is nippled onto one end of the UNR, and the other end of the UNR is nippled into the support outlet box ɀ Set screws are located on each end to lock the nipples in place to prevent loosening in relamping or from vibration ɀ Adjustment of UNR to the angle setting needed provides for the desired angle of the luminaire ɀ Degree markings are cast into the UNR ɀ Two set screws and a large stud and nut are provided, which are tightened to clamp the unit rigid Size Ranges: ɀ Hub – 3⁄4⍯ ɀ Luminaire weight – 125 lbs. Certifications and Compliances: UNR Adjustable Luminaire Hanger Hub Size 3⁄4 Angle Adjustment Cat. # 0° to 90° UNR29 Dimensions Standard Materials: ɀ Feraloy® iron alloy Application: Standard Finishes: COUP locking couplings are used in both hazardous and non-hazardous areas to: ɀ lock a luminaire conduit stem into a conduit hub to prevent the conduit stem from loosening when the luminaire is relamped and torque transferred to luminaire stem ɀ prevent loosening of luminaire stem due to vibration ɀ hang pendant type luminaires from standard cast outlet boxes which do not have set screws in the hub where the luminaire stem is attached ɀ Electrogalvanized and aluminum acrylic paint Size Ranges: ɀ Hub size – 1⁄2⍯ to 1⍯ ɀ Stem size – 1⁄2⍯ and 3⁄4⍯ Certifications and Compliances: ɀ UL Standard: 886 Features: COUP ɀ The large end is slipped over the cast hub and the set screws tightened. The luminaire stem is slipped through the small end and threaded securely into the cast hub. The set screws in the small end are then tightened, thereby preventing the stem from turning ɀ Permits support of luminaire from conduit hub of a hazardous location outlet body Locking Couplings Hub Size 1⁄2 3⁄4 3⁄4 1 Standard Materials: ɀ Feraloy® iron alloy US: 1-866-764-5454 STIBOINFO((CRH:66008com:8L:911)) CH0 7 L - 1 6 CAN: 1-800-265-0502 Stem Size 1⁄2 1⁄2 3⁄4 3⁄4 Copyright© 2006 Cooper Crouse-Hinds Cat. # COUP101 COUP201 COUP202 COUP302 911 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0912-1 Name: Note Page-912 DATE: JAN 19 2006 Time: 6:01:23 PM Operator: JB COLOR: CMYK Notes Page 912 STIBOINFO((CRH:66008com::912)) CH0 3 A - 1 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0913-3 Name: 9L-913 100: DATE: JAN 19 2006 Time: 6:01:24 PM Operator: RB COLOR: CMYK TCP: 15001 Portable Lighting Hazardous and Non-Hazardous Typedriver Name: TS name csm no.: 100 9L Description Page No. Application/Selection 914 Handlamps VS Series Incandescent EVH Series Incandescent EVH Series Fluorescent 915 916 921, 922 Portable Floodlights RCDER Series Incandescent EVP Series H.I.D. 917, 918 919, 920 Worklights EVH Series Fluorescent US: 1-866-764-5454 STIBOINFO((CRH:66008com:9L:913)) CH0 0 0 0 8 L CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 921, 922 913 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0914-2 Name: 9L-914 9L 100: DATE: JAN 19 2006 Time: 6:01:24 PM Operator: JB COLOR: CMYK TCP: 15001 Portable Lighting Hazardous and Non-Hazardous Locations Application and Selection Quick Selector Chart Applications: Portable luminaires and accessories can be used: ɀ in areas made hazardous by the abnormal presence of flammable gases and vapors, combustible dusts or easily ignitable fibers and flyings. ɀ in areas where combustible dusts and flammable gases are present simultaneously. ɀ in aircraft manufacturing and maintenance facilities, shipyards, paint spray booths, refueling depots, storage tank cleanings, railcar manufacturing and maintenance facilities, refineries, chemical and petrochemical plants, textile mills, grain elevators, pharmaceutical plants, sewage treatment plants and wastewater treatment plants. ɀ during plant ‘shut downs’ for maintenance and installation requirements. ɀ in any adverse environment where portable lighting is preferred or required. ɀ in locations where fixed lighting is not practical. ɀ for task oriented lighting. ɀ for emergency lighting applications. ɀ when inspecting aircraft wing tanks, vats, process vessels, fuel tanks, etc. (handlamps). Considerations for Selection: Environmental: ɀ What is the hazardous area classification (NEC/CEC) of the location in which the luminaires will be installed? ɀ What wattages and light source (ie. fluorescent) will provide the desired light levels? ɀ Type of luminaire required: handlamp, portable flood or other special requirements. Table 500-3(d) Identification Numbers. Maximum Temperature Deg. C Deg. F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185 Identification Number T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Quick Selector Chart Luminaire Lamp Watts Volts EVH Handlamp (Incandescent) Cl. I, Groups C and D Cl. II, Group G Cl. III 100 max. 250 vac EVH Handlamp (Fluorescent) Cl. I, Groups C and D Cl. II, Groups E, F, G Cl. III 13, 15 120, 220-50 EVP Cl. I, Groups C and D Cl. II, Groups F and G Cl. III 35-150 120, 277, 347 RCDER Cl. I, Groups C and D 150-500 VS Non-Hazardous areas 100 max. 914 STIBOINFO((CRH:66008com:9L:914)) CH0 0 8 L - 0 NEC Hazardous Area Compliances US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0915-6 Name: 9L-915 100: DATE: JAN 19 2006 Time: 6:01:25 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Weather Resistant VS Portable Hand Lamps 9L Incandescent Accessories Glass Globes Application: The incandescent VS portable hand lamps are used: ɀ in wet or corrosive locations to exclude moisture, dirt, corrosive chemicals, etc. ɀ where an incandescent lamp of up to 100 watts is required in a portable hand lamp Polycarbonate Globes Features: ɀ Enclosed and gasketed ɀ Flexible cord or cable is attached through a watertight gland in the handle ɀ Is of rugged construction ɀ Clamp type guard available ɀ Provision is made in the lamp receptacle for a third conductor to ground all non-currentcarrying metal parts Description Clear Glass, (Heat Resisting) Clear, Polycarbonate, Plain Standard Materials: ɀ Handle – molded rubber ɀ Globe – clear, plain glass ɀ Guard – cast aluminum or steel wire (No Cable Included) Standard Finishes: ɀ Handle – Natural ɀ Guard – Zinc plated Options: ɀ Materials: heat resistant glass globe; polycarbonate globe Size Ranges: Globe Length 67⁄8 Max Lamp Size 100 W A-23† Cord Dia. .125 to .625 Maximum Lamp Size Cat. # 100W, A-23 – 67⁄8⍯† V63 75W, A-21⍯† V470 Size 67⁄8 globe Cat. # VS97 Rubber Cat. # VS30 Note: Furnished with clear globe, wire guard and 4 rubber bushings. ɀ Up to 100 watt, A-23 lamp ɀ .250 to .625 cord O.D. Certifications and Compliances: ɀ Weather resistant ɀ UL Standard: 298 Guards Description Steel Wire (Note: CEC/CSA Certified VS handlamps - Cooper CrouseHinds Canada fixtures only.) Lamp Receptacle (medium base) Description Composition keyless Size 660W, 600V Cat. # GS156 Cord Gland Bushings Description Size Cat. # Rubber .125 to .250 Cord BUSH92 .250 to .375 Cord BUSH93 .375 to .500 Cord BUSH 94 .500 to .625 Cord BUSH05 † Will take lamps with maximum dimensions of 61⁄2⍯ long and 27⁄8⍯ diameter. US: 1-866-764-5454 STIBOINFO((CRH:66008com:9L:915)) CH0 0 8 L - 1 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 915 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0916-2 Name: 9L-916 9L 100: DATE: JAN 19 2006 Time: 6:01:27 PM Operator: JB EVH Portable Handlamp COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1 & 2, Group G Cl. III Cl. I, Zone 1 IIB Application: EVH106 is used: ɀ as a portable handlamp in hazardous areas ɀ in inspecting aircraft wing tanks, vats, process vessels, fuel tanks, etc. Features: ɀ Pressure connector terminals for portable cord ɀ Light weight – 41⁄4 lbs. ɀ Designed for rough service – swivel hook, ease in relamping Standard Materials: ɀ Guard and globe holder – copper-free aluminum ɀ Handle – molded phenolic composition ɀ Globe – glass, heat and impact resistant Standard Finishes: ɀ Natural Size Ranges: ɀ #16 – 3 type SO cord/cable is to be used (not supplied) Capacity Ranges: ɀ 50 to 100 watt, A-21 ɀ Max. volts – 250 VAC Certifications and Compliances: ɀ NEC/CEC: Class I, Division 1 and 2, Groups C, D – 100 watts max. Class I, Zone 1 IIB Class II, Division 1 and 2, Group G – 75 watts max. Class III – 75 watts max. ɀ UL Standard: 781 ɀ CSA Standard: C22.2 No. 137 Temperature Performance Data: (based on 40°C Ambient) Class I, Groups C, D Class II, Group G Class III T3C Cat. # Cord Dia. EVH106 .375 to .625 (Model M10) Replacement Parts Description Guard & globe assembly Handle assembly (including lampholder) Cord connector assembly Lampholder only Note: See Section 2P of this catalog for suitable male plug. 916 STIBOINFO((CRH:66008com:9L:916)) CH0 0 8 L - 2 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Cat. # EVH606 EVH607 EVH605 20V19-001 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0917-2 Name: 9L-917 100: DATE: JAN 19 2006 Time: 6:01:28 PM Operator: JB Incandescent Application: Standard Materials: RCDER portable incandescent luminaires provide general illumination in locations having hazardous atmospheres, such as: ɀ oil refineries ɀ oil and gasoline loading docks ɀ aircraft servicing docks and shelters ɀ distilleries ɀ paint manufacturing plants ɀ pumping stations ɀ other Class I, Groups C and D locations ɀ Body – copper-free aluminum; Lens – glass, heat and impact resistant ɀ Wheel base ɀ Carrying handle ɀ Adjustment allows rotation of 75° vertically. ɀ Locking screws hold housing firmly in position ɀ Door which threads into housing includes heat and impact-resistant lens. Door has notches or projections for ease of removing or tightening ɀ Factory sealed TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 and 2, Groups C, D Cl. I, Zone 1 II(B) A Portable Floodlights Features: COLOR: CMYK 9L Standard Finishes: ɀ Natural Size Ranges: ɀ Take cable with O.D. of .375⍯ to .500⍯ Capacity Ranges: ɀ RCDER-6 – 150 watt, PAR38 or R40; 300 watt, R40 (medium base) ɀ RCDER-10 – 500 watt, PAR64 (Ext. Mog End Prong) Certifications and Compliances: ɀ NEC/CEC: RCDER – Class I, Division 1 and 2, Groups (C), D Class I, Zone 1 II(B) A (see photometric data listing) ɀ UL Standard: 844 ɀ CSA Standard: C22.2 No. 137 (RCDER-6 only) RCDER-6 Cat. # 44655B RCDER-10 Cat. # 47283A Note: CEC/CSA Certified RCDER6 - Cooper Crouse-Hinds Canada luminaires only. Ordering Information: After identifying the hazardous area, select the model of luminaire required for that area. Then from the photometric data, select appropriate Cat. No. based on type of mounting desired. Example: RCDER-10 No. 47283A Temperature Performance Data (based on 40°C Ambient) RCDER-6 RCDER-10 150W T3B 300W T2B 500W T3C US: 1-866-764-5454 STIBOINFO((CRH:66008com:9L:917)) CH0 0 8 L - 3 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 917 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0918-2 Name: 9L-918 DATE: JAN 19 2006 Time: 6:01:29 PM Operator: JB COLOR: CMYK TCP: 15001 Portable Mounted Lights 9L Photometric Data Dimensions and Weights RCDER Photometric Data Beam Spread Lamp Watts and Type Location 150 Watt PAR38 Flood 150 Watt PAR38 Spot Class I Groups C, D (Zone 1 IIB) Hor. Vert. Beam Lumens Av. Max. Candle Power 60° 60° 1690 4000 28° 28° 1200 11500 123° 123° 3200 1950 60° 60° 3100 8900 19° 14° 3000 110000 Model RCDER-6 300 Watt R40 Flood 300 Watt R40 Spot Class I Group D (Zone 1 IIA) 500 Watt, PAR64 (500 PAR64/NSP) 500 Watt, PAR64 (500 PAR64/MFL) Class I, Group D 35° 19° 3300 37000 500 Watt, PAR64 (500 PAR64/WFL) (Zone 1 IIA) 55° 32° 3400 13000 RCDER-10 Dimensions RCDER-6 RCDER-10 Fixture Weights RCDER-6 Cat. # 44655 918 STIBOINFO((CRH:66008com:9L:918)) CH0 0 8 L - 4 RCDER-10 Lbs. (Net) 26.0 Cat. # 47283 US: 1-866-764-5454 Lbs. (Net) 25.0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0919-2 Name: 9L-919 100: DATE: JAN 19 2006 Time: 6:01:29 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups C, D Cl. II, Div. 1 & 2, Groups F, G Cl. III Cl. I, Zone 1 IIB Wet Locations Marine Locations EVP Portable H.I.D. Floodlight 9L Features and Benefits: Product Features ɀ Strong spun aluminum wheel base. User Benefits ɀ Provides stability, allows fixture to be hung on a wall or lowered in an inverted position. ɀ Sturdy hand knob. ɀ Tightens to hold position for steady illumination and easy aiming. ɀ Plastic rib covered handle. ɀ Firm, non-slip grip for transporting fixture. ɀ Aluminum specular reflector. ɀ Tempered, 3⁄4⍯ thick cover glass. ɀ Nitrile rubber O-ring gasket. ɀ Strain-relief clamps. ɀ Directs intense beam for better visibility. ɀ Heavy duty service. ɀ Pre-wired, factory-sealed 100′ of 16/3 type SOW cord supplied. ɀ Saves on installation time and maintenance costs. ɀ Light weight (25 lbs.). ɀ Fixture housing has a safety yellow finish. ɀ Easy to handle when transporting. ɀ Highly visible for safety precautions. ɀ Excellent sealing for use in wet locations. ɀ Provides extra protection against cord damage. Ordering Information: Cl. I, Div. 1, Groups C, D Cl. II, Div. 1, Group F Applications: The EVP portable H.I.D. floodlight† is suitable for maintenance or emergency lighting: ɀ in areas made hazardous by the presence of flammable gases and vapors, combustible dusts, or easily ignitable fibers and flyings. ɀ in aircraft manufacturing and maintenance facilities, shipyards, refueling depots, storage tank cleaning, railcar manufacturing and maintenance facilities, refineries, chemical and petrochemical plants, textile mills, grain elevators and pharmaceutical plants, printing operations, wastewater and sewage treatment plants. ɀ in any adverse environment where portable lighting is preferred or required. ɀ in locations where lighting is not practical. ɀ for task oriented lighting. Standard Materials: ɀ Housing – copper-free aluminum ɀ Wheel base – spun aluminum ɀ Handle – plastic rib covered aluminum ɀ Reflector – aluminum ɀ O-ring gasket – Nitrile rubber Cat. # 70 watts HPS, 120 volts 100 watts HPS, 120 volts 150 watts HPS, 120 volts 70 watt MH, 120 volts 70 watt MH, 277 volts 70 watt MH, 347 volts * Class II not available. EVP4070 EVP4100 EVP4150* EVP9070 EVP9070/277 EVP9070/347 Cl. I, Div. 1, Groups C, D Cl. II, Div. 1, Groups F, G Cl. III Cat. # 100 watts HPS, 120 volts 70 watt MH, 120 volts 70 watt MH, 277 volts 70 watt MH, 347 volts EVPG4100 EVPG9070 EVPG9070/277 EVPG9070/347 Fixtures for grain dust applications have a special limiting device to prevent the fixture head from being positioned in an upright position limiting dust buildup. Temperature Performance Data: Cat. # Max. Ambient °C Class I, Division 1 T-Rating Groups Class II, Division 1 T-Rating Groups EVP4070 EVP4100 EVP4150 EVP9070 EVPG4100 EVPG9070 40 40 25 40 40 40 T4A T4A T3C T4 T4A T4 T3 T3 — T3 T3C T4 C, D C, D C, D C, D C, D C, D F F — F F, G F, G Certifications and Compliances: EVP and EVPG ɀ NEC/CEC: Class I, Division 1 & 2, Groups C, D Class I, Zone 1 IIB Class II, Division 1 and 2, Groups F, G Class III Wet Locations Marine Locations ɀ UL Standards: 781, 595, 1572 ɀ CSA Standard: C22.2 No. 137, No. 12 Electrical Ratings High pressure sodium – (medium base) ɀ 70, 100, & 150 watt ɀ 120 volt 60Hz Metal Halide – (double end) ɀ 70 watt ɀ 120, 277 & 347 volt; 60Hz † EVP fixtures are not supplied with plug. US: 1-866-764-5454 STIBOINFO((CRH:66008com:9L:919)) CH0 0 8 L - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 919 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0920-2 Name: 9L-920 9L DATE: JAN 19 2006 Time: 6:01:30 PM Operator: JB EVP Portable H.I.D. Floodlight COLOR: CMYK TCP: 15001 Photometric Data Dimensions and Weights Fixture Weight: 25.5 lbs. Candelas - Thousands Photometric Data: EVP4070 EVP4100 EVP4150 Degrees from beam axis Dimensions: 121⁄2⍯ D × 131⁄8⍯ W × 157⁄8⍯ H 920 STIBOINFO((CRH:66008com:9L:920)) CH0 0 8 L - 6 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0921-3 Name: 9L-921 100: DATE: JAN 19 2006 Time: 6:01:31 PM Operator: TB EVH Fluorescent Handlamps & Worklights COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 and 2, Groups C, D Cl. II, Div. 1, Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III Cl. I, Zone 1, IIB 9L Application: Portable handlamps and worklights can be used: ɀ in areas made hazardous by the presence of flammable gases and vapors, combustible dusts or easily ignitable fibers & flyings. ɀ in aircraft manufacturing and maintenance facilities, shipyards, refueling depots, storage tank cleaning, railcar manufacturing and maintenance facilities, refineries, chemical and petrochemical plants, textile mills, grain elevators, pharmaceutical plants, sewage treatment plants and wastewater treatment plants. ɀ during plant ‘shut downs’ for maintenance and installation requirments. ɀ in any adverse environment where portable lighting is preferred or required. ɀ in locations where fixed lighting is not practical. ɀ for task oriented lighting. ɀ for emergency lighting applications. ɀ when inspecting aircraft wing tanks, vats, process vessels, fuel tanks, etc. Features: ɀ built in metal reflector which eliminates glare and blinding, focusing all light on subject. ɀ protected by patented shock absorbers to withstand rough usage. ɀ enclosed ballast, remote from light source for easier handling and maneuverability. ɀ special rubber compound bumper guards and end caps combined with cast guard and metal rods, protecting against damage from falling objects, bumping, or dropping. ɀ luminaires come complete with lamp(s) and cord. ɀ The New EVH2625E and EVH2650E incorporate an electronic ballast in the handle for efficiency, cool operation and easy handling. Ambient Temperature) Class I, Div. 1 ɀ Body and In line Ballast Unit – aluminum ɀ Tubeshield – annealed glass ɀ Bumper guards – rubber Cat. No. EVH1525 EVH1550 EVH1325 EVH1350 EVH2625 EVH2650 EVH1325 IB EVH1350 IB EVH2625E EVH2650E Standard Finishes: Ordering Information: Standard Materials: ɀ Aluminum Body – White epoxy (handlamps) ɀ Aluminum Body – Natural (worklights) ɀ In Line Ballast Unit – Natural ɀ Rubber bumper guards – safety yellow Line Voltage (60 Hz) 120 120 ɀ Supplied with 18/3 SOW cord (25 ft or 50 ft) Electrical Ratings: Groups D D C, D C, D C, D C, D C, D C, D C, D C, D Class II, Div. 1 T-Rating T5 T5 T5 T5 T3 T3 T5 T5 T6 T6 Groups E, F, G E, F, G E, F, G E, F, G E, F, G E, F, G E, F, G E, F, G E, F, G E, F, G Watts 15 15 Cord Length (ft) 25 ft. 50 ft. Lamp Type Cat. No. F15T8 EVH1525 F15T8 EVH1550 EVH Fluorescent Handlamps (With Magnetic Ballast in Cord) ɀ 13 to 26 Watts ɀ Max. Volts 220VAC Line Voltage (60 Hz) 120 120 120 120 Certifications and Compliances: ɀ NEC: Fluorescent Workights (15 watt units) Class I, Div. 1 and 2, Group D Class I, Zone 1 IIB Class II, Div. 1, Groups E, F, G Class II, Div. 2, Groups F, G Class III ɀ NEC: Fluorescent Handlamps (13 and 26 watt units) Class I, Div. 1 and 2, Groups C, D Class II, Div. 1, Groups E, F, G Class II, Div. 2, Groups F, G Class III ɀ FM: Classification 3615 ɀ CSA: C22.2 220 220 220 220 Cord Length (ft) 25 ft. 50 ft. 25 ft. 50 ft. Lamp Type F13TT F13TT F26DTT F26DTT Cat. No. EVH1325 EVH1350 EVH2625 EVH2650 13 13 26 26 25 ft. 50 ft. 25 ft. 50ft. F13TT F13TT F26DTT F26DTT EVH1325/220 50 EVH1350/220 50 EVH2625/220 50 EVH2650/220 50 New – EVH Fluorescent Handlamps (With Electronic Ballast in Handle) ɀ An isolated ballast is available on the EVH 13 Watt handlamps for additional protection, use suffix IB. US: 1-866-764-5454 Watts 13 13 26 26 (50 Hz) Options: STIBOINFO((CRH:66008com:9L:921)) T-Rating T5 T5 T5 T5 T3 T3 T5 T5 T6 T6 EVH Fluorescent Worklights Size Ranges: CH0 0 8 L - 8 Temperature Performance Data: (Based on 40°C Line Voltage (60 Hz) Watts 120 26 120 26 CAN: 1-800-265-0502 Cord Length (ft) Lamp Type 25 ft. CF26DD/E/841 50 ft. CF26DD/E/841 Copyright© 2006 Cooper Crouse-Hinds Cat. No. EVH2625E EVH2650E 921 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0922-2 Name: 9L-922 9L 100: DATE: JAN 19 2006 Time: 6:01:32 PM Operator: JB EVH Fluorescent Handlamps & Worklights COLOR: CMYK TCP: 15001 Dimensions Dimensions (inches) Work Light Hand Lamp (Magnetic Ballast Handlamps Only) 922 STIBOINFO((CRH:66008com:9L:922)) CH0 0 8 L - 9 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0923-4 Name: 10L-923 100: DATE: JAN 19 2006 Time: 6:01:33 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Exit Signs and Emergency Luminaires Hazardous and Non-Hazardous 10L Description Page No. Exit Signs EXL Series EVLPF(B)-EXD DMVF(B)-EXD 924, 925 926 927 Light-Pak TM – Emergency Lighting Systems ELPS Series N2LPS Series Remote Luminaire Heads EVLA N2RF 928, 929 930, 931 928, 930 930 Compact Fluorescent Emergency Luminaires CPMVFB DMVFB EVLPFB 932, 933 934, 935 936, 937 Table 500-3(d) Identification Numbers. Maximum Temperature Deg. C Deg. F 450 842 300 572 280 536 260 500 230 446 215 419 200 392 180 356 165 329 160 320 135 275 120 248 100 212 85 185 US: 1-866-764-5454 STIBOINFO((CRH:66008com:10L:923)) CH0 0 0 0 9 L CAN: 1-800-265-0502 Identification Number T1 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Copyright© 2006 Cooper Crouse-Hinds 923 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0924-2 Name: 10L-924 100: DATE: JAN 19 2006 Time: 6:01:34 PM Operator: JB COLOR: CMYK Factory Sealed Application: EXL exit signs are used: ɀ in locations deemed hazardous due to the presence of flammable vapors or gases, or combustible dusts ɀ in any building or enclosed area where people work – where illuminated exit signs are required ɀ to provide distinct, highly visible exit marking ɀ to indicate the direction of travel to exits Features: ɀ Two incandescent lamps (not included) wired in parallel – to provide extra margin of light source reliability ɀ Solid state circuit for extended lamp life in AC units ɀ Six inch red letters on white acrylic sign panel make word ‘‘exit’’ stand out boldly and clearly ɀ Edge lighting characteristic of sign panel makes visibility excellent at all lighting levels ɀ Factory sealed explosion-proof housing ɀ Pendant, wall and end bracket mounts provide universal installation options ɀ Impact-resistant acrylic sign panel needs no guard – makes cleaning easy ɀ Internal rectifier extends lamp life beyond 1,000-hour rated life – reduces relamping cost ɀ Relamping tool provided Standard Materials: ɀ Body – copper-free aluminum ɀ Sign panel – acrylic Conduit Entrance: ɀ 3⁄4⍯ hubs Lamp Wattage: ɀ Two 60-watt, 60T10 clear lamps for AC units ɀ Two 25-watt, 25T10 clear lamps for DC units ɀ Lamps not included with luminaire Electrical Ratings: ɀ 120VDC or 120VAC operation. Certifications and Compliances: ɀ NEC: Class I, Groups C and D Class II, Groups E, F, and G ɀ UL Standard: 844 ɀ NFPA Life Safety Code No. 101-1991 Class I (C,D) Class II (E,F,G) T3C T3C Ordering Information: I. When ordering an EXL Series Exit Sign, you will need to specify: (A) Voltage (120VAC or 120VDC) (B) Mounting (Wall, End Bracket, or Pendant) (C) Exit Sign Designation All units come standard with 3⁄4⍯ hubs and exit signs with red lettering and white background. Complete catalog numbering is as follows: EXL (A) 2 (B) (C) (A) Voltage: 120VAC . . . . . . . . . . leave blank 120VDC . . . . . . . . . . . . . . . . . . . D (B) Mounting: Wall . . . . . . . . . . . . . . . . . . . . . 1 End Bracket. . . . . . . . . . . . . . 2 Pendant . . . . . . . . . . . . . . . . . 3 (C) Exit Sign Designation: A Single Face (Wall Mount) AA Double Face (End Bracket & Pendant) AB Double Face, one side arrowhead right, the other no arrowhead (End Bracket & Pendant) AC Double Face, one side arrowhead left, the other no arrowheads (End Bracket & Pendant) AD Double Face, one side arrowhead both ends, the other no arrowheads (End Bracket & Pendant) B Single Face, arrowhead right (Wall Mount) BC Double Face, one side arrowhead right, the other arrowhead left (End Bracket & Pendant) BD Double Face, one side arrowhead both ends, the other arrowhead right (End Bracket & Pendant) C Single Face, arrowhead left (Wall Mount) CD Double Face, one side arrowhead both ends, the other arrowhead left (End Bracket & Pendant) D Single Face, arrowhead both ends (Wall Mount) DD Double Face, both sides arrowhead both ends (End Bracket & Pendant) Pendant Style End Bracket Style Wall Style Ordering Examples Table: Temperature Performance Data (for both AC & DC operation): Ambient Temp (°C) 25 40 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups C, D Cl. I, Zone 1 IIB Cl. II, Div. 1, Groups E, F, G EXL Explosionproof Exit Sign 10L TCP: 15001 Supply Wire °C 150°C Mounting Type Sign Panel Description Wall Single face End bracket Pendant Hub Size AC Cat. # DC Cat. # 3⁄4 EXL21A EXLD21A Double face 3⁄4 EXL22AA EXLD22AA Double face 3⁄4 EXL23AA EXLD23AA Suffix Options: Exit Signs with green lettering on white background . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GN Unit Provided with Epoxy powder Coat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S752 277VAC – (Order ECT413 Transformer Separately) 924 STIBOINFO((CRH:66008com:10L:924)) CH0 1 0 L - 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0925-2 Name: 10L-925 100: DATE: JAN 19 2006 Time: 6:01:35 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 EXL Explosionproof Exit Sign 10L Factory Sealed Dimensions Pendant Style Wall Style End Bracket Style US: 1-866-764-5454 STIBOINFO((CRH:66008com:10L:925)) CH0 1 0 L - 2 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 925 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0926-2 Name: 10L-926 10L 100: DATE: JAN 19 2006 Standard Materials: EVLPF(B)-EXD exit signs are used: ɀ in any building or enclosed area where people work - where illuminated exit signs are required ɀ to provide distinct, highly visible exit marking ɀ to indicate the direction of travel to exits ɀ in locations deemed hazardous due to the presence of flammable vapours or gases, or combustible dusts ɀ Mounting modules, cover, ballast housing, globe holder – copper free aluminum ɀ Globe – heat and impact resistant glass ɀ Exterior hardware – stainless steel About the battery: ɀ Bodine fluorescent battery pack ballasts are UL Component Recognized ɀ Sealed, maintenance-free, hightemperature nickel-cadmium ɀ Solid state chargers are sealed inside the ballast case ɀ 90 minute illumination time ɀ 10-year life expectancy ɀ 2-year full warranty ɀ During emergency use 1 lamp has continuous operation ɀ A red indicator light indicates the battery is charging ɀ Wiring instructions for a ⍯Push-to-Test⍯ button is supplied with the luminaire Standard Finishes: Copper-free aluminum – Corro-free TM powdered epoxy Ratings (Electrical/Size): Sources/wattage: ɀ 52W (2-26W lamps) ɀ 120-277V, 50-60Hz ɀ 120V, 60Hz ɀ 347V, 60Hz Conduit entries: ɀ 3⁄4⍯, 1⍯ NPT – Pendant, Wall Bracket, Ceiling Energy Savings ɀ Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output ɀ NEC and CEC: - Class I, Division 1, Groups B (GB suffix), C, D - Class I, Zone 1 Groups IIB + H2 (GB Suffix), IIB, IIA - Class II, Class III & Simultaneous Presence (Class I and Class II) ɀ UL Standards - 844 Hazardous (Classified) Locations - 1598 Luminaires - 1598A Marine Locations ɀ CSA Standards - C22.2 No. 137 Description Group B suitability Factory assembled with lamps Suffix to be added to Cat. # GB FA Ordering Information: Mounting Type Pendant Wall STIBOINFO((CRH:66008com:10L:926)) Certification & Compliances: Options: Ceiling 926 Typedriver Name: TS name csm no.: 100 ɀ Marine & Wet Locations Cl. I, Div 1, Groups B (suffix GB), ɀ 3, 3R, 4, 4X; IP66 C, D ɀ Cl. I, Zone 1, Groups IIB + H2 (GB suffix), IIB ɀ Cl. II, Div 1, Groups E, F, G; Class III, Simultaneous Presence Application: ɀ Six inch red letters on white glass sign panel make the word ‘‘ EXIT’’ stand out boldly and clearly ɀ Light weight copper-free aluminum housing with powdered epoxy finish ɀ All exterior hardware is corrosion-resistant stainless steel ɀ Three mounting arrangements pendant, ceiling and wall bracket ɀ Integral ballast ɀ High power factor (90%+) ballasts ɀ Easier assembly, installation and maintenance ɀ Outdoor, hose down, marine and corrosive environments suitable ɀ Ideal for adverse environments typical of industrial facilities ɀ Ground wire for safety ɀ Optional battery backup for operation during power outage TCP: 15001 ɀ EVLPF(B) - Exit Sign Fluorescent Luminaire Features - Benefits: CH0 0 6 L 1 7 Time: 6:01:36 PM Operator: JB COLOR: CMYK US: 1-866-764-5454 Supply Voltage Volts/Hertz 120-277V / 50-60Hz 120V / 60Hz (Canada) 347V / 60Hz 120-277V / 50-60Hz 120V / 60Hz (Canada) 347V / 60Hz 120-277V / 50-60Hz 120V / 60Hz (Canada) 347V / 60Hz CAN: 1-800-265-0502 Catalog Number Fluorescent with Battery Back-up EVLPFA02520/UNV-EXD EVLPFBA02520/UNV-EXD EVLPFBA0520/120CAN-EXD EVLPFA02520/347-EXD EVLPFBA0520/347-EXD EVLPFCX02520/UNV-EXD EVLPFBCX02520/UNV-EXD EVLPFBCX02520/120CAN-EXD EVLPFCX02520/347-EXD EVLPFBCX02520/347-EXD EVLPFBX02520/UNV-EXD EVLPFBBX02520/UNV-EXD EVLPFBBX02520/120CAN-EXD EVLPFBX02520/347-EXD EVLPFBBX02520/347-EXD Fluorescent Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0927-2 Name: 10L-927 100: DATE: JAN 19 2006 DMVF(B) - Exit Sign Fluorescent Luminaire Time: 6:01:37 PM Operator: JB COLOR: CMYK ɀ Cl. I, Div. 2; Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Typedriver Name: TS name csm no.: 100 ɀ Cl. II, Groups E, F, G, Cl. III & Simultaneous Presence ɀ Marine & Wet Locations ɀ 3, 3R, 4X; IP66 Application: Standard Materials: DMVF(B) exit signs are used: ɀ in any building or enclosed area where people work. ɀ where illuminated exit signs are required. ɀ to provide distinct, highly visable exit markings. ɀ to indicate the direction of travel to exits. ɀ in locations deemed hazardous due to the presence of flammable vapors or gases, or combustible dusts. ɀ Ballast housings and mountings - copperfree aluminum (less than 0.4 of 1%). ɀ Exterior hardware - stainless steel. ɀ Globe - heat and impact resistant internally fluted glass. Features: Electrical Rating Ranges: ɀ Six inch letters on white glass sign panel make the word ‘‘exit’’ stand out boldly and clearly. ɀ Housings made of die-cast copper-free aluminum (less than 0.4 of 1% copper) for strength and resistance to corrosion). ɀ Mounting module equipped with integral hub set screws for vibration resistance (ceiling and pendant mounts). ɀ Hubs are provided with an integral conduit stop and bushing to help prevent damage to field wiring during installation. ɀEpoxy powder finish and stainless steel external hardware for resistance to corrosion. ɀ Long life gaskets which provide seals between mounting module, housing, and globe assembly. ɀ Grounding wire for safety. ɀ Cool operating design. ɀ Optional emergency battery backup operation during power outage. ɀ 52 Watt. ɀ 120-277V, 50-60 Hz. ɀ 120V, 60 Hz. ɀ 347V, 60 Hz. About the battery: ɀ NEC and CEC: Class I, Division 2, Groups A, B, C, D ɀ Class II, Class III & Simultaneous Presence (Class I Division 2 and Class II) Class I Zone 2 ɀ IEC: Zone 2 Ex nR IIC ɀ UL Standards: 844, 2279 Hazardous (Classified) Locations. 1598 Luminaires. 1598A Marine Luminaires. ɀ CSA Standards: C22.2 No. 137 ɀ IEC Standards: 60079-15 ɀ Bodine fluorescent battery pack ballasts are UL Component Recognized. ɀ Sealed, maintenance-free, hightemperature nickle-cadmium ɀ Solid state chargers are sealed inside the ballast case. ɀ 90 minute illumination time. ɀ 10-year life expectancy. ɀ 2-year full warranty. ɀ During emergency use, 1 lamp has continuous operation. ɀ A red indicator light indicates the battery is charging. ɀ Wiring instructions for a ‘‘Push-to-Test’’ button is supplied with the fixture. TCP: 15001 10L Standard Finishes: ɀ Aluminum - gray epoxy powder coat. ɀ Krydon material - high reflectance white. ɀ Stainless steel - natural. Options: Description Lamps supplied with exit sign Top hat with stainless steel threaded insert. Restricted breathing construction. Class I Division 2 & Zone 2 suitability. Cooler operating temperatures (T -Numbers). Certified for IEC Zone 2 (Suffix S826TB). Furnished with Terminal Block. Crimp Terminals. Dedicated voltage ballasts (no MT, DT or TT). Suffix added to Cat. No. S714 S806 S826 S826TB Certifications and Compliances: Energy Savings ɀ Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output. Ordering Information: Mounting Type Pendant Ceiling Wall US: 1-866-764-5454 STIBOINFO((CRH:66008com:10L:927)) CH0 0 9 L - 3 Supply Voltage Volts/Hertz 120-277V / 50-60Hz 120V / 60Hz (Canada) 347V / 60Hz 120-277V / 50-60Hz 120V / 60Hz (Canada) 347V / 60Hz 120-277V / 50-60Hz 120V / 60Hz (Canada) 347V / 60Hz CAN: 1-800-265-0502 Catalog Number Fluorescent with Battery Back-up DMVF2A052G/UNV-EXD DMVFB2A052G/UNV-EXD DMVFB2A052G/120CAN-EXD DMVF2A052G/347-EXD DMVFB2A052G/347-EXD DMVF2C052G/UNV-EXD DMVFB2C052G/UNV-EXD DMVFB2C052G/120CAN-EXD DMVF2C052G/347-EXD DMVFB2C052G/347-EXD DMVF2TW052G/UNV-EXD DMVFB2TW052G/UNV-EXD DMVFB2TW052G/120CAN-EXD DMVF2TW052G/347-EXD DMVFB2TW052G/347-EXD Fluorescent Copyright© 2006 Cooper Crouse-Hinds 927 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0928-15 Name: 10L-928 10L DATE: JAN 19 2006 ELPS Light-Pak TM Emergency Lighting System Time: 6:01:38 PM Operator: RB COLOR: CMYK TCP: 15001 Cl. I, Div. 1 & 2; Groups C, D Cl. I, Div. 1 & 2, Groups B, C, D (With suffix GB) Cl. II, Div. 1; Groups E, F, G Cl. III Typedriver Name: TS name Cl. I, Zone 1 Simultaneous Presence Wet Locations NEMA 3, 3R, 12 Application: ELPS series emergency lighting systems are used: ɀ to provide safe, reliable illumination indoors or outdoors to designated areas during failure or interruption of power to the normal lighting system ɀ in areas made hazardous by the presence of flammable gases and vapors, combustible dusts or easily ignitible fibers and flyings ɀ in areas where corrosion, vibration, moisture, dirt and rough usage may be encountered ɀ where required by the National Electrical Code®, the Life Safety Code or other codes ɀ in refineries, chemical and petrochemical facilities, grain processing, handling or storage facilities, manufacturing plants, waste water treatment facilities and other areas where safe, reliable, hazardous area emergency lighting is needed Features: ɀ Compact factory sealed luminaire assemblies are each furnished with a 12 watt tungsten-halogen lamp and inner reflector for appropriate photometrics in hazardous areas. ɀ Luminaire assemblies are fully adjustable and lockable on two axes to provide flexible and consistent light aiming capabilities. ɀ Luminaire lens ring is threaded for easy relamping and locks in place with hex head set screw; will not loosen due to vibration. ɀ Ground joint cover with external flange design permits large opening and easy access to internal components. Stud bolts in diagonally opposite corners of body ease cover removal and installation. ɀ Neoprene cover gasket seals out moisture for superior protection of internal components against wetness and corrosion. ɀ Light weight, compact size, and mounting feet ease installation and allow placement in confined areas. ɀ Two 1⍯ NPT drilled and tapped conduit openings, with plugs, are standard, for choice of top or bottom feed. ɀ Factory-installed PUSH-TO-TEST pushbutton enables easy testing of system. ɀ MAIN POWER ON pilot light indicates AC power is being supplied to the battery charger; pilot light jewel is threaded for easy lamp replacement. ɀ Stainless steel drain minimizes moisture collection. Stainless steel breather with aluminum cap provides ventilation, minimizes moisture collection. ɀ CID 101 corrosion inhibitor device is provided with each ELPS system to help protect electrical components and connections. ɀ Rugged, long-life, maintenance-free, nickel cadmium battery provides 30 watts of power for the required 11⁄2 hours. ɀ Solid state battery charger for long life and reliable service prevents deep discharge by automatically disconnecting luminaires from battery. 928 STIBOINFO((CRH:66008com:10L:928)) CH0 0 9 L - 3 ɀ Terminal block facilitates field wiring connections. ɀ Instruction sheet and maintenance record card provided with unit in a protective plastic envelope. ɀ A time delay is standard; time delay is preset at factory for 5 minute delay but can be field set for 5 seconds or 15 minutes, thus allowing HID type lamps time to restrike and reach desired illumination levels. ɀ Solid state battery charger will accept 120, 220/240 or 277 VAC, 50/60 Hz. Electrical Ratings: ɀ Power supply: Input: 120, 220/240, 277 VAC, 50 or 60 hertz 0.5 Amps Maximum Output: 12 VDC UL listed for 28 watts for 11⁄2 hours at 0° – 40°C ɀ Luminaires: Voltage: 12 VDC Lamp Type: #789, miniature Tungsten halogen, G4, 2-pin, 14 watt. Certifications and Compliances: ɀ NEC: Class I, Groups B, C, D Class II, Groups E, F, G Class III Simultaneous Presence ɀ NEMA: 3R, 4X*, 12 (ELPS power supply) ɀ Suitable for wet locations (EVLA fixtures) ɀ Marine (EVLA fixtures) ɀ UL Standard: 844 – Electric Luminaire – Hazardous Locations 924 – Emergency Lighting and Power Equipment 1203 – Explosionproof and DustIgnition-Proof Electrical Equipment ɀ Life Safety Code: Section 5-9 (Emergency Lighting) ɀ Suitable for Wet Locations ɀ NEMA 3, 3R, 12 ɀ Marine Standard Materials: ɀ Power supply enclosure and luminaire assembly – copper-free aluminum (less than 0.4 of 1% copper) Standard Finishes: ɀ Power supply enlosure and fixture assemblies—powder coat epoxy paint finish Ordering Information: CATALOG NUMBER ELPS502* DESCRIPTION Standard unit with adjustable heads ELPS-K50 Replacement power interior, includes circuit board and battery pack ELPS50* Power Supply EVLA12* Lamphead and arm ELPS502-EXD Exit sign, double sided with EVI, red letters ELPS502-EXD GN Exit sign, double sided with EVI, green letters ELPS502-EXD GB Exit sign, single or double sided with Group B EVA, red letters ELPS502-EXD GB GN Exit sign, single or double sided with Group B EVA, green letters ELPS502-EXS Exit sign, single sided with EVI, red letters ELPS502-EXS GN Exit sign, single sided with EVI, green letters * Base unit comes standard with Class I, Division 1, Group B. Options: ɀ Remote mounted EVLA12 lamp head mounted to a Cooper Crouse-Hinds EABC36 or EABL36 1⍯ NPT outlet box ɀ S794 key operated disconnect switch as part of the ELPS502 emergency light system ɀ S854 keyless operated designated disconnect switdch as part of the ELPS502 emergency light system * NEMA 4X pending with new ECD 4X breather and drain US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0929-15 Name: 10L-929 DATE: JAN 19 2006 ELPS Light-Pak TM Emergency Lighting System Time: 6:01:39 PM Operator: RB COLOR: CMYK TCP: 15001 Temperature Performance Data Photometric Data Dimensions and Weights Typedriver Name: TS name csm no.: 100 10L Photometric Data: Temperature Performance Data: EVLA12—Maximum Ambient Temperature 55°C (131°C) EVLA12 Temperature Codes (T-numbers): ɀ Class ɀ Class ɀ Class I—T4A II*—T3B III*—T3B * For Class II and Class III applications, fixtures must not be aimed more than 30° above horizontal (see diagram below). ELPS EVI & ELPS EVA—Maximum Ambient Temperature 40°C ɀ Class I—T4 ɀ Class II—T3C Dimensions Unit Net Weights: ɀ ELPS502 complete emergency lighting system – 50 lbs. ɀ ELPS50 power supply – 40 lbs. ɀ EVLA12 luminaire assembly – 5 lbs. Status Indication LED Status ɀ ɀ ɀɀ ɀɀɀ ɀɀɀɀ US: 1-866-764-5454 STIBOINFO((CRH:66008com:10L:929)) CH0 1 0 L - 4 Condition No light Steady light (no blinking) Light blinks once Light blinks twice Light blinks three times Light blinks four times CAN: 1-800-265-0502 Meaning of the Indication AC power is removed from the circuit Fully charged Charging Battery failure Circuit failure Lamp failure Copyright© 2006 Cooper Crouse-Hinds 929 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0930-3 Name: 10L-930 10L 100: DATE: JAN 19 2006 Time: 6:02:44 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 2, Groups B, C, D Class I, Zone 2 Wet Locations NEMA 3, 3R LIGHT-PAK TM N2LPS Emergency Lighting System Application: Light-Pak N2LPS emergency lighting systems are used: ɀ to provide reliable illumination for egress areas during failure or interruption of power to the normal lighting system ɀ in areas where flammable gases or vapors may become present due to abnormal, unusual, or accidental conditions ɀ in manufacturing plants, refineries, petrochemical and chemical plants, waste and sewage treatment facilities, oil terminals, food processing facilities, breweries, and other industrial manufacturing or process industry facilities subject to wet or corrosive conditions ɀ to illuminate machinery or panels during a loss of AC power ɀ where moisture, dirt, dust, or corrosion will limit the life and reliability of ordinary emergency lighting systems ɀ where required by the National Electrical Code®, the Life Safety Code® or other applicable codes ɀ Outdoor applications Features: ɀ Compact factory assembled system with two 8 watt sealed beam halogen lamps. ɀ Nonmetallic, enclosed and gasketed construction; a CID101 corrosion inhibitor device is also included. ɀ Solid state battery charger will accept 120, 220, and 277 VAC, 50/60 Hz. ɀ A time delay is standard; time delay is preset at factory for 5 minute delay but can be field set for 5 seconds or 15 minutes, thus allowing HID type lamps time to restrike and reach desired illumination levels. ɀ ‘‘Push-to-Test’’ button and ‘‘Main Power On’’ pilot light are conveniently located on side of system. ɀ Sealed, lead calcium battery(ies); one battery supplies 28 watts of power (two batteries 56 watts) for 11⁄2 hrs. ɀ Luminaire heads constructed of rugged Noryl® thermoplastic material with nylon and plastic coated hardware. ɀ Cover has six captive stainless steel screws; factory installed 3⁄4⍯ conduit hub opening is standard, located on top of system. ɀ Remote luminaire head assemblies (one or two) are available for mounting of luminaire heads away from main power supply system. Temperature Performance Data: (based on 40°C ambient) Cat. # Class I, Division 2 N2LPS (all) T4A N2RF (all) T5 (NOTE: Ambient temperature at which the Light-Pak system is rated is 0°C (32°F) to 40°C (104°F). Lower ambient temperatures will reduce battery capacity.) National Electrical Code and Life Safety Code are registered trademarks of the National Fire Protection Association, Inc. Noryl is a registered trademark of General Electric Company. 930 STIBOINFO((CRH:66008com:10L:930)) CH0 1 0 L - 5 Standard Materials: Ordering Information: ɀ Power supply and remote luminaire enclosures – Krydon® fiberglass-reinforced polyester ɀ Luminaire heads – Noryl® thermoplastic ɀ Exterior hardware – Nylon, plastic coated, and stainless steel ɀ Cover gasket – Hypalon® synthetic rubber Description Cat. # 28 watt, 6 volt output power supply with two 8 watt tungsten halogen luminaires . . N2LPS6222 56 watt, 6 volt output power supply with two 8 watt tungsten halogen luminaires . . N2LPS6422 28 watt, 6 volt output power supply only (less luminaire heads) . . . . . . . . . . . . . . . . . . . . . N2LPS6220 56 watt, 6 volt output power supply only (less luminaire heads) . . . . . . . . . . . . . . . . . . . . . N2LPS6420 Remote luminaire assembly with one 8 watt luminaire head N2RF621 Remote luminaire assembly with two 8 watt luminaire heads . . . . . . . . . . . . . . . . . . . . . N2RF622 Remote luminaire assembly with one 12 watt 6 volt lamp for mounting in Class 1, Division 1, Group C and D areas . . . . . . . . . . . . . . . . EVLA126 Power supply with two 8 watt tungsten halogen luminaires and single face exit sign. Exit sign operates in emergency mode only.. . . . . N2LPS6422-EXS Power supply with two 8 watt tungsten halogen luminaires and double face exit sign. Exit sign operates in emergency mode only. . . . . . . . . . . . . . . . . . . . . . . . . . N2LRS6422-EXD Electrical Ratings: ɀ Power supply – Input: 120, 220, or 277 VAC, 50 or 60 Hz; 25 watts max. Output: 6 VDC; N2LPS6222, N2CPS6220 – 28 watts for 11⁄2 Hrs. N2LPS6422, N2LPS6420 – 56 watts for 11⁄2 Hrs. ɀ Luminaires – Voltage: 6 VDC; Lamp type: 8 watt, tungsten halogen PAR36 sealed beam (General Electric #H7551) Certifications and Compliances: ɀ NEC – Class I, Division 2, Groups B,C,D ɀ UL Standards: 924 (Emergency Lighting and Power Equipment); 844 (Electric Luminaires Hazardous Locations) ɀ Life Safety Code NFPA101® – Section 5-9 (Emergency Lighting) ɀ Wet Locations Suitability Unit Net Weights: ɀ N2LPS6222 – 16 lbs. ɀ N2LPS6422 – 21 lbs. ɀ N2LPS6220 – 12 lbs. ɀ N2LPS6420 – 17 lbs. ɀ N2RF621 – 6 lbs. ɀ N2RF622 – 8 lbs. US: 1-866-764-5454 CAN: 1-800-265-0502 Option: Suffix to be Added to Cat. # Description N2LPS6422 with exit sign EXS or EXD that operates in both normal and emergency mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S840 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0931-2 Name: 10L-931 100: DATE: JAN 19 2006 Time: 6:02:45 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Photometric Data Dimensions and Weights LIGHT-PAK TM N2LPS Emergency Lighting System 10L Photometric Data: Isofootcandle Chart Horizontal Distribution Vertical Distribution Wire Sizing for Remote Installation: For Copper Wire – Running Distance* (ft.) Between Power Supply and Remote Luminaire Load In Watts Wire Size 8 16 24 16 AWG 26 13 6 14 AWG 42 21 10 12 AWG 66 33 16 * Maximum distance to limit line voltage drop to 5%. 32 3 5 8 Wire Size 10 AWG 8 AWG 6 AWG Dimensions (N2LPS): 8 106 168 270 Load In Watts 16 24 53 26 84 42 135 67 32 13 21 33 Weights: Description Weight N2LPS6222 (28 watt system). . . . . . . . . 16 lbs. N2LPS6422 (56 watt system). . . . . . . . . 21 lbs. Weights: Description Weight N2RF621 (8 watt) . . . . . . . . . . . . . . . . . . . . 6 lbs. N2RF622 (16 watt) . . . . . . . . . . . . . . . . . . . 8 lbs. Dimension: Dimensions – Remote Luminaires (N2RF621 – N2RF622) US: 1-866-764-5454 STIBOINFO((CRH:66008com:10L:931)) CH0 1 0 L - 6 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 931 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0932-8 Name: 10L-932 10L 100: DATE: JAN 19 2006 Time: 6:02:47 PM Operator: RB CPMVFB Emergency Compact Fluorescent Continuous Operation Champ-Pak TM Luminaires Application: ɀ where emergency lighting is required to permit workers in industrial areas to safely encounter their surroundings during power failures ɀ where emergency egress lighting is required, such as: catwalks, walkways, tunnels, doorways, stairs, stairwells, ramps and aisles ɀ indoor and outdoor wall mounting or vertical surface mounting where minimal luminaire depth is required in: - Manufacturing plants and heavy industrial facilities - Industrial process facilities such as refineries, chemical, petrochemical, pharmaceutical and platforms - Waste or sewage treatments plants - Offshore, dockside and harbor installations ɀ For security and safety lighting in industrial facilites for lighting of loading docks, tunnels and stairways ɀ For marine, wet location, hosedown and corrosive environments Features & Benefits: ɀ Unique compact shallow-profile design mounts virtually anywhere ɀ Side hinged cover with two screw closing for easy installation and maintenance ɀ Gray Corro-free TM epoxy powder coat two-piece housing provides superior corrosion resistance ɀ Unique stainless steel wire guard accessory attaches without any additional hardware for easy installation and maintenance ɀ Glass refractor provides uniform light distribution to eliminate glare ɀ Silicon gaskets make luminaire suitable for NEMA 4X, Marine enviroments ɀ High power factor ballasts (+90%) are standard, which allow more luminaires per circuit COLOR: CMYK TCP: 15001 ɀ Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence * ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 ɀ Emergency Lighting Certifications and Compliances: ɀ NEC and CEC: Class I, Division 2, Groups A, B, C, D Class II, Class III & Simultaneous Presence (Class I Division 2 and Class II) Class I Zone 2 ɀ IEC: Zone 2 Ex nR IIC ɀ UL Standards 844, 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations ɀ CSA Standards C22.2 No. 137 ɀ IEC Standards 60079-15 About the battery: ɀ Bodine fluorescent battery pack ballasts are UL Component Recognized ɀ Sealed, maintenance-free, high-temperature nickel-cadmium ɀ Solid state chargers are sealed inside the ballast case ɀ 90 minute illumination time ɀ 10-year life expectancy ɀ 2-year full warranty ɀ During auxiliary use 1 lamp has continuous operation ɀ A red indicator light indicates the battery is charging ɀ Wiring instructions for a ‘‘Push-to-Test’’ button is supplied with the fixture Electrical Rating Ranges: ɀ 52 watts ɀ 120-277V, 50-60Hz ɀ 120V, 60Hz ɀ 347V, 60Hz Standard Materials: Options: Standard Finishes: Restricted Breathing Construction Class I Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-numbers) Certified for IEC Zone 2 (Suffix S826TB) S826TB Furnished with Terminal Block Crimp Terminals Dedicated voltage ballasts (no MT, DT or TT) Factory Assembled with Lamp installed FA Fused - projects ballast and capacitors against S658† abnormal line conditions (Not for use in Canada) (Not for Marine use) ɀ Luminaire housing and door frame assembly - copper-free aluminum ɀ External hardware - stainless steel ɀ Lens - heat and impact-resistant refractor style glass ɀ Gaskets - silicon rubber ɀ Reflector - aluminum light sheet ɀ Wire guard - stainless steel ɀ Aluminum - Corro-free TM epoxy powder coat ɀ Stainless steel - natural * Consult Cooper Crouse-Hinds Suffix to be added to Cat. # S826 Accessories: Stainless Steel Wire Guard † When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. 932 STIBOINFO((CRH:66008com:10L:932)) CH0 0 9 L - 3 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Cat. # P55 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0933-6 Name: 10L-933 DATE: JAN 19 2006 Time: 6:02:48 PM Operator: JB COLOR: CMYK CPMVFB Emergency Compact Fluorescent TCP: 15001 Ordering Information Dimensifons & Weights Typedriver Name: TS name csm no.: 100 10L Continuous Operation Champ-Pak TM Luminaires Ordering Information: Lamp Hub Size Watts Catalog Number for use with ANSI Lamps 3⁄4NPT CPMVFB2W026 26 Standard Voltage Ballasts NEC/UL CEC/CSA (cUL) Voltage 120-277V 50-60Hz 120V/60Hz 347V 60Hz Suffix /UNV /120CAN /347 Dimensions (Inches): Net Weight: Luminaire Less Guard P55 Guard 18.6 Lbs. 0.5 Lbs. US: 1-866-764-5454 STIBOINFO((CRH:66008com:10L:933)) CH0 1 0 L - 1 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 933 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0934-4 Name: 10L-934 10L 100: DATE: JAN 19 2006 DMVFB Emergency Compact Fluorescent Continuous Operation Champ® Luminaires Time: 6:02:49 PM Operator: RB COLOR: CMYK ɀ Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Application: Energy Savings DMVF series Champ lighting luminaires are used: ɀ where emergency lighting is required to permit workers in industrial areas to safely encounter their surroundings during power failures. ɀ Where emergency egress lighting is required, such as: catwalks, walkways, tunnels, doorways, stairs, stairwells, ramps, and aisles. ɀ in areas made hazardous by abnormal conditions resulting in the presence of flammable vapors or gases. ɀ in areas made hazardous by the presence of combustible dusts. ɀ where combustible dusts and flammable vapors are present simultaneously. ɀ in marine applications where water spray and corrosive atmospheres are considerations. ɀ on installations where vibration and rough usage are problems. ɀ where a cool, efficient light source is required. ɀ in areas that require lamps to reach full illumination immediately. ɀ in refineries, chemical and petrochemical facilities, grain processing, handling or storage facilities, manufacturing plants waste water treatment plants sewage treatment plants, oil terminals, food processing facilities, breweries, and any other manufacturing or processing facility where safe, reliable, hazardous area fluorescent or auxiliary lighting is needed. ɀ Less wattage used with compact fluorescent lamps compared to equivalent incandescent lamps providing the same light output. Standard Features: ɀ Housings made of die-cast copper-free aluminum (less than 0.4 of 1% copper) for strength and resistance to corrosion. ɀ Mounting modules equipped with integral hub set screws for vibration resistance (ceiling, pendant, and quad mounts). ɀ Hubs are provided with an integral conduit stop and bushing to help prevent damage to field wiring during installation. ɀ Epoxy powder finish and stainless steel external hardware for resistance to corrosion. ɀ Long-life gaskets which provide seals between mounting module, housing, and optical assembly. ɀ Grounding wire for safety. ɀ Cool operating design. ɀ Optional stainless steel open bottom guard permits direct access to the globe for easy relamping. ɀ Battery pack ballast for emergency lighting. TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl.III & Simultaneous Presence ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 ɀ Emergency Lighting About the battery: (DMVFB Units) ɀ Bodine fluorescent battery pack ballasts are UL Component Recognized. ɀ Sealed, maintenance-free, hightemperature nickel-cadmium ɀ Solid state chargers are sealed inside the ballast case. ɀ 90 minute illumination time ɀ 10-year life expectancy ɀ 2-year full warranty ɀ During auxiliary use 1 lamp has continuous operation ɀ A red indicator light indicates the battery is charging. ɀ Wiring instructions for a ‘‘Push-to-Test’’ button is supplied with the luminaire. Standard Materials: ɀ Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1%). ɀ Exterior hardware and guards – stainless steel. ɀ Reflectors – Krydon® fiberglass-reinforced polyester material. ɀ Globe – heat and impact resistant internally fluted glass. Standard Finishes: ɀ Aluminum – gray epoxy powder coat. ɀ Krydon material – high reflectance white. ɀ Stainless steel – natural. Electrical Rating Ranges: ɀ 52 and 64 watts ɀ 120-277V, 50-60 Hz ɀ 347V, 60 Hz Certifications and Compliances: ɀ NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Class III & Simultaneous Presence (Class I Division 2 and Class II) Class I Zone 2 Emergency Lighting ɀ IEC Zone 2 Ex nR IIC ɀ UL Standards 844, 2279 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations 924 Emergency Lighting ɀ CSA Standards C22.2 No. 137 ɀ IEC Standards 60079-15 Options: Suffix to be Description added to Cat. No. ɀ Restricted Breathing Construction S826 - Class I Division 2 & Zone 2 Suitability - Cooler Operating Temperatures (T-Numbers) ɀ Certified for IEC Zone 2 (Suffix S826TB) S826TB - Furnished with Terminal Block Crimp Terminals ɀ Emergency Operation only Consult Crouse- Hinds ɀ Factory Assembled with lamps installed for additional labor savings . . . . . . . add suffix FA. ɀ Fused – to protect ballast against abnormal line conditions (not for use in Canada) (not for Marine use) . . . . . . . add suffix S658.* ɀ Lamps supplied with luminaire . . . add suffix S714. ɀ Top hat with stainless steel threaded insert to attach ballast housing . . . . add suffix S806. ɀ TEFLON® coating on globe for increased shatter protection . . . . . . . . . . add suffix S808. Accessories: (Order separately) ɀ Dome Cat. # RD739 ɀ 30° Angle Cat. # RA739 * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. 934 STIBOINFO((CRH:66008com:10L:934)) CH0 1 0 L - 7 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0935-3 Name: 10L-935 DATE: JAN 19 2006 DMVFB Emergency Compact Fluorescent Continuous Operation Champ® Series Luminaires Time: 6:02:50 PM Operator: RB ɀ Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div 2 & Zone 2 (Suffix S826) ɀ Certified for IEC Zone 2 (Suffix S826TB) ɀ Mounting Style Pendant Mount Lamp Watts 52 Flexible Pendant Mount 3⁄4 3⁄4 52 64 DMVFB2HA052GP DMVFB2HA064GP Ceiling Mount ThruFeed 3⁄4 52 1 3⁄4 1 64 DMVFB2C052GP DMVFB3C052GP DMVFB2C064GP DMVFB3C064GP 3⁄4 52 1 3⁄4 1 64 Wall Mount Thru-Feed TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Cl. II Groups E, F, G, Cl. III & Simultaneous Presence ɀ Marine & Wet Locations ɀ 3, 3R, 4, 4X; IP66 ɀ Emergency Lighting 10L DMVFB Series Fluorescent with Battery Back-Up with G303 Globe and P33 Guard Cat. No. DMVFB2A052GP DMVFB3A052GP DMVFB2A064GP DMVFB3A064GP Hub Size 3⁄4 1 3⁄4 1 64 COLOR: CMYK DMVFB2TW052GP DMVFB3TW052GP DMVFB2TW064GP DMVFB3TW064GP Quad-Mount Pendant, Adjustable Thru-Feed, 25° Angle, 12-1/2° Angle 3⁄4 3⁄4 52 64 DMVFB25Q052GP DMVFB25Q064GP Stanchion Mount 25° Angle 1-1⁄2 1-1⁄2 52 64 DMVFBJ052GP DMVFBJ064GP Stanchion Mount Straight 1-1⁄2 1-1⁄2 52 64 DMVFBP052GP DMVFBP064GP Note: For technical information on family trees, temperature performance data, dimensions, weights, and photometrics, refer to DMVF Series in Section 6L. NOTES: 1. Catalog numbers are basic numbers. Voltage must be specified. Standard Voltage Ballasts NEC/UL Voltage Suffix US: 1-866-764-5454 STIBOINFO((CRH:66008com:10L:935)) CH0 1 0 L - 8 120-277V 50-60Hz /UNV CAN: 1-800-265-0502 CEC/CSA (cUL) 120V/60Hz /120CAN Copyright© 2006 Cooper Crouse-Hinds 347V 60Hz /347 935 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0936-4 Name: 10L-936 10L 100: DATE: JAN 19 2006 Time: 6:02:51 PM Operator: JB COLOR: CMYK EVLPFB Emergency Compact Fluorescent Continuous Operation Low Profile Luminaires TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ ɀ Marine & Wet Locations Cl. I, Div. 1, Groups B ɀ 3, 3R, 4, 4X; IP66 (GB Suffix), C, D ɀ Cl. I, Zone 1, Groups ɀ Emergency Lighting IIB + H2 (GB suffix), IIB, IIA ɀ Cl. II, Div. 1, Groups E, F, G; Class III, Simultaneous Presence Application: Cooper Crouse-Hinds Low Profile Hazard ȿ Gard® luminaires are used in: ɀ areas that require lamps to reach full lumination immediately. ɀ where emergency lighting is required to permit workers in industrial areas to safely encounter their surroundings during power failures. ɀ where emergency lighting is required such as: catwalks, walkways, tunnels, doorways, stairs, stairwells, ramps and aisles. ɀ areas where flammable or explosive vapors or gases are present ɀ hazardous areas, both indoors and outdoors, where long life and low maintenance costs are desired ɀ petroleum refineries, chemical, petrochemical and pharmaceutical plants, oil terminals, gas plants and other heavy process industry facilities ɀ waste treatment facilities ɀ drilling platforms and other coastal and offshore hazardous areas ɀ Mounting modules, cover, ballast housing, globe holder – copper free aluminum ɀ Globe – heat and impact resistant glass ɀ Exterior hardware – stainless steel ɀ Reflectors (dome & angle) – Krydon TM fiberglass-reinforced polyester Standard Finishes: Copper-free aluminum – Corro-free TM powdered epoxy ɀ Krydon – white ɀ Stainless steel guard Features - Benefits: Ratings (Electrical/Size): ɀ Small compact size ɀ Two start Acme threaded construction ɀ Easier assembly, installation and maintenance ɀ Light weight copper-free aluminum housing with powdered epoxy finish ɀ All exterior hardware is corrosion-resistant stainless steel ɀ Four mounting arrangements pendant, ceiling, wall bracket and stanchion ɀ Integral ballast ɀ High power factor (90%+) ballasts ɀ Uses same mounting modules as the standard Hazard ȿ Gard® ɀ Internally fluted glass globes ɀ Krydon® construction dome and angle reflectors – won’t rust, corrode, dent, chip or peel ɀ Now available in components – luminaire body, mounting module, guard, reflectors ɀ Three wire construction ɀ For energy conservation, luminaires can be switched off without affecting the emergency operation feature Sources/wattage: ɀ Fluorescent continuous operation Emergency Lighting 52W (2-26W lamps) and 64W (2-32W lamps) Compact fluorescent Voltages: ɀ Fluorescent Emergency Lighting – 120-277V, 50-60 Hz – 120V, 60 Hz – 347V 60Hz Conduit entries: ɀ 3⁄4⍯, 1⍯ NPT – pendant, wall bracket, ceiling ɀ 11⁄4⍯ NPT – stanchion Standard Materials: Description Dome reflector Angle reflector ɀ Mounting modules, cover, ballast housing, globe holder – copper free aluminum ɀ Globe – heat and impact resistant glass ɀ Exterior hardware – stainless steel ɀ Reflectors (dome & angle) – Krydon TM fiberglass-reinforced polyester Energy Saving: ɀ Less wattage used with compact fluorescent lamps compared to equivalet incandecent lamps providing the same light output. 936 STIBOINFO((CRH:66008com:10L:936)) CH0 1 0 L 2 0 Standard Materials: Certification & Compliances: ɀ NEC and CEC: Class I, Division 1, Groups B (with GB suffix), C, D Class I, Zone 1 Groups IIB + H2 (GB Suffix), IIB, IIA Class II, Class III & Simultaneous Presence (Class I and ClassII) Emergency Lighting ɀ UL Standards 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations 924 Emergency Lighting ɀ CSA Standards C22.2 No. 137 Options: Description Group B suitability Fused (not for use in Canada) (not for Marine use) Factory assembled with lamps Emergency Operation only Suffix to be added to Cat. # GB S658* FA Consult Cooper Crouse-Hinds Accessories: Cat. # RD739 RA739 About the Battery ɀ Bodine fluorescent battery pack ballasts are UL Component Recognized. ɀ Sealed, maintenance-free, hightemperature nickle-cadmium. ɀ Solid state chargers are sealed inside the ballast case. 90 minute illumination time. 10-year life expectancy ɀ 2-year warranty. ɀ During emergency use, 1 lamp has continuous operation. ɀ A red indicator light indicates the battery is charging. ɀ Wiring instructions for a ‘‘Push-to-Test’’ button is supplied with the fixture. US: 1-866-764-5454 CAN: 1-800-265-0502 * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0937-2 Name: 10L-937 100: DATE: JAN 19 2006 EVLPFB Emergency Compact Fluorescent Continuous Operation Low Profile Luminaires Time: 6:02:52 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 ɀ Marine & Wet Locations Cl. I, Div. Groups B ɀ 3, 3R, 4, 4X; IP66 (GB suffix), C, D ɀ Emergency Lighting ɀ Cl. I, Zone 1, Groups IIB + H2 (with Suffix GB), IIB, IIA ɀ Cl. II, Div 1, Groups E, F, G; Class III, Simultaneous Presence ɀ 10L Ordering Information Luminaire Body Less Mounting Module & Guard Pendant Wall Bracket† Ceiling† Stanchion Hub With Guard With Guard With Guard With Guard Catalog # Catalog # Catalog # Catalog # Watt Size Catalog # Fluorescent with Emergency Ballast – High Power Factor Ballast (Min. P.F. 90%) EVLPFBA02521 EVLPFBBX02521 EVLPFBCX02521 EVLPFB0520 52W 3⁄4 1 EVLPFBA03521 EVLPFBBX03521 EVLPFBCX03521 EVLPFBJ04521 11⁄4 64W 3⁄4 EVLPFBA02641 EVLPFBBX02641 EVLPFBCX02641 EVLPFB0640 1 EVLPFBA03641 EVLPFBBX03641 EVLPFBCX03641 EVLPFBJ04641 11⁄4 Pendant Mount Complete Catalog Numbers as follows: 1. Standard Voltage Ballasts NEC/UL Voltage Suffix 120-277V 50-60Hz /UNV CEC/CSA (cUL) 120V/60Hz /120CAN 347V 60Hz /347 Example: EVLPFB02521/UNV 2. Other Voltages - Consult Cooper Crouse-Hinds †Wall Bracket Mount Note: For technical information on family trees, temperature performance data, dimensions, weights, and photometrics, refer to DMVF Series in Section 5L. EVFPFB Fluorescent Emergency Lighting ɀ Three wire construction, for switching purposes, is standard on Fluorescent Emergency Lighting. ɀ For energy conservation, luminaires can be switched off without affecting the emergency operation feature. †Ceiling Mount * Test Switch is remote mounted. Use Cooper Crouse-Hinds EDSC218 (Not furnished). Stanchion Mount †Ceiling and bracket mounts have 4 hubs: 3 are plugged. US: 1-866-764-5454 STIBOINFO((CRH:66008com:10L:937)) CH1 0 L - 2 1 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 937 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0938-1 Name: Note Page-938 DATE: JAN 19 2006 Time: 6:02:53 PM Operator: JB COLOR: CMYK Notes Page 938 STIBOINFO((CRH:66008com::938)) CH0 3 A - 1 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0939-6 Name: 11L-939 100: DATE: JAN 19 2006 Time: 6:02:54 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 2 Visual Signaling Devices ‘‘Steady On’’ Beacons, ‘‘Rotating’’ Beacons and ‘‘Flashing’’ Strobe Lights 11L Luminaires for Hazardous and Non-Hazardous Locations Description Application 940 VF Beacons Fluorescent ‘‘Steady On’’ 941 EX Fire Alarm Strobe Light 942, 944, 949 EX Strobe Light 943, 944, 949 EX Steady-on Beacon 945, 946, 949 EX Rotating Beacon 947, 948, 949 VDAS Strobe Lights 950 US: 1-866-764-5454 STIBOINFO((CRH:66008com:11L:939)) CH0 0 0 0 8 L Page No. CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 939 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0940-9 Name: 11L-940 DATE: JAN 19 2006 Time: 6:02:55 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Visual Signaling Devices ‘‘Steady On’’ Beacons, ‘‘Rotating’’ Beacons and ‘‘Flashing’’ Strobe Lights 11L Luminaires for Hazardous and Non-Hazardous Locations Application: Considerations for Selection: ɀ for use in hazardous and non-hazardous areas (as shown in the quick selector chart shown below). ɀ to supplement audible signals, especially in high noise areas. ɀ as visual signals or warning lights. ɀ to identify the location of safety equipment such as emergency shower, eye wash stations, and emergency telephones, fire extinguishers and emergency stop switches. ɀ for status indication of machinery or processes. ɀ to indicate dangerous areas or areas requiring caution. ɀ to signal dangerous or hazardous conditions. Environmental: ɀ What is the hazardous area classification (NEC/CEC) of the location in which the luminaire will be installed? Signaling Requirements: ɀ What will the visual signal be used for (Communicating, alerting, warning)? Physical Arrangements: ɀ Type of luminaire mounting needed. Quick Selector Chart: Series VF - ‘‘Steady On’’ Beacons EX Strobes, Steady-On Beacons, & Rotating Beacons VDAS Strobes Hazardous Area Suitability CL. I, Div 2, Groups A, B, C, D CL. I, Zone 2, Group IIC Wet Locations - 3, 3R Cl. I, Div. I, Groups C,D Cl. I, Zone 1 & 2, Group IIB Cl. II, Div. I, Groups E,F,G Wet Locations - 4X, Marine CL. I, Div 2, Groups A, B, C, D CL. I, Zone 2, Group IIC CL. II, Div 2, Groups F, G; Cl. III Wet Locations - 3, 3R, 4, 4X Warning and Visual Indication Colors Available Green Blue Red Yellow Clear 940 STIBOINFO((CRH:66008com:11L:940)) CH0 0 1 1 - 0 US: 1-866-764-5454 CAN: 1-800-265-0502 Lamp Watts (2) 9W Xenon Strobe Halogen Beacon Xenon Strobe Volts 120V 60 Hz. 120 VAC 24 VDC 12-48 VDC 24-28 VDC 120V 60 Hz 240V 60 Hz 12-24VDC Typical Uses Emergency Shower or Eye Wash Station Emergency Telephones Danger, Equipment Operating Caution Equipment end of cycle Copyright© 2006 Cooper Crouse-Hinds No. of Lamps 2 1 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0941-3 Name: 11L-941 DATE: JAN 19 2006 VF ‘‘Steady On’’ Beacon Compact Fluorescent Warning and Visual Indication Light Time: 6:02:55 PM Operator: JB COLOR: CMYK ɀ ɀ ɀ ɀ Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Groups IIC ɀ Wet Locations ɀ 3, 3R TCP: 15001 Typedriver Name: TS name csm no.: 100 Green - Safety Shower Blue - Emergency Telephones ɀ Red - Danger ɀ Amber - Warning ɀ Visual Signal Application: Options: VF series ‘‘Steady On’’ fluorescent beacons are used indoors or outdoors: ɀ where the energy efficiency and long life of compact fluorescent lamps are desired ɀ for continuous signaling requirements. ɀ where a continuous ‘‘Steady-On’’ fluorescent light signal is required ɀ where ambient noise makes audible signals difficult to hear. ɀ as visual signals or warning lights on loading docks; at obstructions, exits or entrances. ɀ for identifying the location of safety equipment such as safety showers or emergency telephones. ɀ for call signals. ɀ for status indication or area lighting on offshore rigs, mines, refineries etc. ɀ in locations which are hazardous due to the presence of flammable vapors or gases and where dampness or corrosion are present. ɀ to identify a potentially dangerous obstacle. ɀ as a continuous source to warn or communicate. Typical Applications are: ɀ Green - Identify safety shower locations ɀ Blue - Identify emergency telephones ɀ Amber - Caution signal ɀ Red - Danger signal ɀ Red & Amber - Emergency situations ɀ Blue & Red - Security or malfunctioning equipment. ɀ Green & Clear - Equipment end of cycle. Description Features: ɀ Extremely energy efficient, only 18 watt (2-9 watt compact fluorescent lamps) ɀ Packs considerable punch for ample visibility even in harsh enviroments. ɀ Compact size and light weight allow adaptation and easy installation in many industrial applications ɀ Cast copper-free aluminum (less than 0.4 of 1% copper) construction and epoxy powder finish provide excellent resistance to corrosion ɀ Variety of mounting arrangements to suit any lighting layout – pendant, ceiling, wall bracket, angle stanchion. ɀ Glass globes are internally fluted and stippled to enhance visibility. Exteriors are smooth to shed dust ɀ Grounding wire for safety ɀ 250 volt Nameplate for export applications Weights: 11L Suffix added to Cat. No. /250 2-Lamp Luminaire With Globe & Guard (lbs.) 5 51⁄4 71⁄2 Luminaire Type VFA VFHF VFHBF Temperature Performance Data: Style 1 & 2 Class I Lamp Div. 2 9W T3B Max. Ambient 40°C Supply Wire °C 75°C Minimum Operating –4°C (25°F) Certifications and Compliances: NEC and CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2 ɀ UL Standards 844 1598 Luminaires ɀ CSA standards c22.2 No. 137 Dimensions Pendant Wall VFA Stanchion VFHBF VFHA Ceiling Standard Materials: ɀ Bodies and guards – copper-free aluminum (less than 0.4 of 1%) ɀ Globes – glass Standard Finishes: VFHF ɀ Copper-free aluminum – powder epoxy finish Electrical Ratings: ɀ Input voltage – 120 VAC, 60 hertz ɀ Wattages: 18W (Two 9W lamps) Ordering Information: Style Pendant Wall Ceiling Stanchion US: 1-866-764-5454 STIBOINFO((CRH:66008com:11L:941)) CH0 1 0 L - 1 Red Catalog Number - by Globe Color Amber Green Blue Clear VFA222GRP VFHBF222GRP VFHF222GRP VFHA422GRP VFA222GAP VFHBF222GAP VFHF222GAP VFHA422GAP VFA222GP VFHBF222GP VFHF222GP VFHA422GP CAN: 1-800-265-0502 VFA222GGP VFHBF222GGP VFHF222GGP VFHA422GGP Copyright© 2006 Cooper Crouse-Hinds VFA222GBP VFHBF222GBP VFHF222GBP VFHA422GBP 941 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0942-9 Name: 11L-942 11L 100: DATE: JAN 19 2006 Time: 6:02:56 PM Operator: RB HazardɀGard EX Series Visual Signaling Devices Explosionproof Fire Alarm Strobe Light COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G ɀ Class III UL 1638, 1203 and 1971 Listed NEMA 4X watertight, IP 66 The HazardɀGard TM EXFASC Series is a visual fire alarm signaling device for hazardous areas. The EXFASC Series strobes are UL 1971 Listed for indoor signaling applications for the hearing impaired in non-sleeping areas. They are also UL listed for Type 3R, 4X installations. The strobes are available for pendant, wall and ceiling mounts. The EXFASC Series Fire Alarm Explosionproof Strobe contains a supervisory diode for use in fire alarm applications. Under normal operation the diode is reversed biased, meaning it blocks voltage from being applied to the strobe light and prevents it from lighting. When a fire-initiating device such as a smoke alarm is activated, the diode’s polarity is reversed through a fire alarm panel. The diode becomes forward biased, allowing voltage to the device and activating the strobe. Primary Applications ɀ Visual fire alarm signaling device for hazardous areas Typical Industries ɀ Energy exploration ɀ Utilities ɀ Wastewater treatment plants ɀ Pulp & paper plants ɀ Petrochemical plants ɀ Petroleum refineries ɀ Oil rigs Key Features and Benefits ɀ Meets NFPA requirements for fire safety warning devices. ɀ State of the art electronic design (full wave rectified design). - Low current draw is efficient. - 24VDC regulated full wave rectified - Limited in-rush current favorable to other fire alarm system components. - Proven, reliable circuitry designed specifically for use with fire alarm control panels. ɀ Available in pendant, wall and ceiling mount. ɀ Strobe light produces 65 flashes per minute. ɀ Factory sealed — no external seals required. ɀ Quick connect — Strobe fixture threads onto mounting module for easy installation. ɀ Small compact size — ceiling mount is 133⁄4-inch long. Certifications and Compliances ɀ Class I, Division 1, Groups C & D ɀ Class I, Zone 1 & 2, Group IIB ɀ Class II, Division 1, Groups E, F & G ɀ Class III ɀ UL 1638 and 1203 Listed ɀ UL 1971 Listed for indoor visual signaling for the hearing impaired in non-sleeping areas ɀ cUL Listed C22.2 No. 205 ɀ NEMA 4X watertight, IP 66 Materials & Finishes ɀ Body, mounting modules and guard — Copper-free aluminum ɀ Globe — Heat and impact-resistant glass ɀ Gaskets — Silicone ɀ External hardware — Stainless steel ɀ Internal components — Solid-state electronics in a moistureresistant and heat-dissipating epoxy ɀ Epoxy powder coated for corrosion resistance Ratings ɀ 16-33VDC ɀ Operating Current: 1.08 - 0.83 amps ɀ Peak Candlepower: 800,000 Hub Size ɀ 3/4-inch NPT pendant, ceiling and wall mount Ordering Information STEP 2 Order Mounting Module STEP 1 Order Strobe Type Catalog Lens NEMA Number Voltage Color Rating FIRE ALARM RATED EXPLOSIONPROOF STROBES EXFASC301/16 33 24VDC regulated Clear 3R, 4X full wave rectified Temperature Performance Data Catalog Number EVMP2 EV22 & EV87 EV22 EVMJ4 Hub Size 3⁄4⍯ 3⁄4⍯ 3⁄4⍯ 11⁄4⍯ See page 944. 942 STIBOINFO((CRH:66008com:11L:942)) CH0 0 4 F - 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Mounting Style Pendant Wall Ceiling Stanchion Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0943-9 Name: 11L-943 100: DATE: JAN 19 2006 Time: 6:02:57 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G ɀ Class III UL 1638, 1203 and 844 Listed 1598A Marine Listed (120VAC and 24VDC only) NEMA 4X watertight, IP 66 HazardɀGard EX Series Visual Signaling Devices Explosionproof Strobe Light 11L Cooper Crouse-Hinds HazardɀGard EXS and EXDS Series Explosionproof Strobe Lights are designed for installation indoors and outdoors in locations which are hazardous due to the presence of flammable vapors or gases, ignitible dusts or ignitible fibers and flyings. The units are UL listed for Type 3R and 4X installations. The 120V and 24VDC models are Marine Rated. The strobes are available for pendant, wall, stanchion and ceiling mounts, and come in six different globe colors. The EXDS Series is diode polarized for use in electrically supervised circuits. Electrically supervised circuits are typically used in life-safety or security applications. Under normal operation the diode is reversed biased, meaning it blocks voltage from being applied to the strobe and prevents it from lighting. When an initiating device such as a smoke detector is activated, the diode’s polarity is reversed through a circuit panel. The diode becomes forward biased, allowing voltage to the device and activating the strobe. Primary Applications Certifications and Compliances ɀ Condition signaling ɀ Equipment obstruction warning ɀ Security alert ɀ Emergency evacuation signaling ɀ In areas where audible signals cannot be heard ɀ Class I, Division 1, Groups C & D ɀ Class I, Zone 1 & 2, Group IIB ɀ Class II, Division 1, Groups E, F & G ɀ Class III ɀ UL and cUL 1638, UL 1203 and UL 844 Listed ɀ 1598A Marine Listed (120VAC and 24VDC only) ɀ cUL Listed C22.2 No. 205 ɀ NEMA 4X watertight, IP 66 Typical Industries ɀ Utility gas plants ɀ Wastewater treatment plants ɀ Mining ɀ Petroleum refineries ɀ Chemical & petrochemical ɀ Pulp & paper Materials & Finishes Key Features and Benefits ɀ Strong strobe signal that produces 65 flashes per minute. ɀ Compact design will not obstruct in low ceiling or small areas. Ceiling mount is only 133⁄4-inch long. ɀ Quick connect — Strobe fixture threads onto mounting module for easy installation. ɀ Factory sealed — No external seals required. ɀ Available in pendant, wall, stanchion and ceiling mount. ɀ Available in six different globe colors — clear, red, blue, amber, green and magenta. ɀ Silicone gasket seals out dirt and moisture. ɀ Body, mounting modules and guard — Copper-free aluminum ɀ Globe — Heat and impact-resistant glass ɀ Gaskets — Silicone ɀ External hardware — Stainless steel ɀ Internal components — Solid-state electronics in a moistureresistant and heat-dissipating epoxy ɀ Epoxy powder coated for corrosion resistance Ratings ɀ 120VAC (EXS), 12–48VDC (EXSNM) and 24VDC nominal, voltage operating range is 16–33VDC (EXDS) ɀ Operating Current: 0.10 amps at 120VAC 1.2–3.8 amps at 12–48VDC 0.8 amps at 24VDC ɀ Peak Candlepower: 800,000 Hub Size ɀ 3/4-inch NPT pendant, ceiling and wall mount ɀ 11⁄4-inch NPT stanchion mount US: 1-866-764-5454 STIBOINFO((CRH:66008com:11L:943)) CH0 0 4 F - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 943 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0944-13 Name: 11L-944 11L DATE: JAN 19 2006 Time: 6:02:58 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G ɀ Class III UL 1638, 1203 and 844 Listed 1598A Marine Listed (120VAC and 24VDC only) NEMA 4X watertight, IP 66 HazardɀGard EX Series Visual Signaling Devices Explosionproof Strobe Light Ordering Information STEP 2 Order Mounting Module STEP 1 Order Strobe Type Catalog Number Voltage EXPLOSIONPROOF STROBES EXS301A/120 120VAC EXS301B/120 120VAC EXS301C/120 120VAC EXS301G/120 120VAC EXS301M/120 120VAC EXS301R/120 120VAC EXSNM301A/12 48 12–48VDC EXSNM301B/12 48 12–48VDC EXSNM301C/12 48 12–48VDC EXSNM301G/12 48 12–48VDC EXSNM301M/12 48 12–48VDC EXSNM301R/12 48 12–48VDC Lens Color NEMA Rating Amber Blue Clear Green Magenta Red Amber Blue Clear Green Magenta Red 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X 3R, 4X 3R, 4X 3R, 4X 3R, 4X 3R, 4X DIODE POLARIZED EXPLOSIONPROOF STROBES EXDS301A/24 24VDC Amber EXDS301B/24 24VDC Blue EXDS301C/24 24VDC Clear EXDS301G/24 24VDC Green EXDS301M/24 24VDC Magenta EXDS301R/24 24VDC Red 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine Catalog Number EVMP2 EV22 & EV87 EV22 EVMJ4 Hub Size 3⁄4⍯ 3⁄4⍯ 3⁄4⍯ 11⁄4⍯ Mounting Style Pendant Wall Ceiling Stanchion Temperature Performance Data Ambient Max. Temp. 40°C 55°C Supply Wire 75°C 90°C Class I Div. 1, 2 Group C, D Class I, Zone 1 Group II B T6(85°C) T5(100°C) EXS Series Strobe Light Voltage 120VAC (Marine Listed) 40°C 55°C 65°C 75°C 90°C 105°C T6(85°C) T6(85°C) T6(85°C) T4A(120°C) T4(135°C) T4(135°C) T4A(120°C) T4(135°C) T4(135°C) EXSNM Series Strobe Light Voltage 12-48 VDC (Not Marine Listed) 40°C 55°C 65°C 75°C 90°C 105°C T6(85°C) T6(85°C) T6(85°C) T4A(120°C) T4(135°C) T4(135°C) T4A(120°C) T4(135°C) T4(135°C) EXDS Series Strobe Light-Diode Polarized Voltage 24 VDC (Marine Listed) 40°C 55°C 75°C 90°C T6(85°C) T5(100°C) T4A(120°C) T4(135°C) T4A(120°C) T4(135°C) EXFASC Series Fire Alarm Voltage 24VDC Regulated Full Wave Rectified (Operating Range 16-33VDC) (Marine Listed) 944 STIBOINFO((CRH:66008com:11L:944)) CH0 0 4 F - 5 US: 1-866-764-5454 CAN: 1-800-265-0502 Class II, Class III Div. 1 Group E, F, G T4A(120°C) T4(135°C) Class II, Class III Div. 2 Group F, G T4A(120°C) T4(135°C) Copyright© 2006 Cooper Crouse-Hinds csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0945-10 Name: 11L-945 DATE: JAN 19 2006 Time: 6:02:59 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G ɀ Class III UL 1638, 1203 and 844 Listed 1598A Marine Listed NEMA 4X watertight, IP 66 HazardɀGard EX Series Visual Signaling Devices Explosionproof Steady-On Beacons csm no.: 100 11L Cooper Crouse-Hinds HazardɀGard EXSO and EXDSO (Diode Polarized) Series Explosionproof Steady On Beacons are designed for installation in hazardous locations where a visual signal is required for tough environmental conditions involving corrosives, water, dust and extreme temperature. The units are UL listed for Type 3R, 4X and marine installations. The steady-on beacons are available for pendant, wall, stanchion and ceiling mounts, and come in six different globe colors. Typical industrial and commercial applications include food processing plants, refineries, mines, tankers, laboratories, sewage treatment plants, off-shore oil rigs, water and filtration plants and chemical plants. The diode polarized steady-on beacon is used in electrically supervised circuitry for life-safety or security applications. Primary Applications ɀ Safety lighting ɀ Continuous source to ɀ Exit or entrance lights communicate ɀ Obstacle warning ɀ For identifying the location of safety equipment such as showers or emergency telephones Typical Industries ɀ Chemical plants ɀ Storage handling ɀ Dust conveyor systems ɀ Energy exploration ɀ Textile mills ɀ Flour and feed mills Key Features and Benefits ɀ Powerful halogen light source for clear visual indication. ɀ Available in six different globe colors — amber, blue, clear, green, magenta and red. ɀ Factory sealed — no external seals required. ɀ Quick connect — Steady-on beacon fixture threads onto mounting module for easy installation. ɀ Small compact size — ceiling mount is 133⁄4-inch long. ɀ Available in pendant, wall, stanchion and ceiling mount. Certifications and Compliances ɀ Class I, Division 1, Groups C & D ɀ Class I, Zone 1 & 2, Group IIB ɀ Class II, Division 1, Groups E, F & G ɀ Class III ɀ UL and cUL 1638, UL 1203 and UL 844 Listed ɀ 1598A Marine Listed ɀ NEMA 4X watertight, IP 66 Materials & Finishes ɀ Body, mounting modules and guard — Copper-free aluminum ɀ Globe — Heat and impact-resistant glass ɀ Gaskets — Silicone ɀ External hardware — Stainless steel ɀ Internal components — Solid-state electronics in a moistureresistant and heat-dissipating epoxy ɀ Epoxy powder coated for corrosion resistance Ratings ɀ 120VAC and 24–28VDC ɀ Operating Current: 0.35 amps at 120VAC (EXSO) 0.8 amps at 24–28VDC (EXDSO, diode polarized) ɀ Peak Candlepower: 3328 Hub Size ɀ 3/4-inch NPT pendant, ceiling and wall mount ɀ 11⁄4-inch NPT stanchion mount US: 1-866-764-5454 STIBOINFO((CRH:66008com:11L:945)) CH0 0 4 F - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 945 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0946-8 Name: 11L-946 11L DATE: JAN 19 2006 Time: 6:03:00 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G ɀ Class III UL 1638, 1203 and 844 Listed 1598A Marine Listed NEMA 4X watertight, IP 66 HazardɀGard EX Series Visual Signaling Devices Explosionproof Steady-On Beacons Ordering Information STEP 2 Order Mounting Module STEP 1 Order Steady-On Beacon Type Catalog Lens Number Voltage Color EXPLOSIONPROOF STEADY-ON BEACONS EXSO301A/120 120VAC Amber EXSO301B/120 120VAC Blue EXSO301C/120 120VAC Clear EXSO301G/120 120VAC Green EXSO301M/120 120VAC Magenta EXSO301R/120 120VAC Red NEMA Rating Catalog Number EVMP2 EV22 & EV87 EV22 EVMJ4 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine Hub Size 3⁄4⍯ 3⁄4⍯ 3⁄4⍯ 11⁄4⍯ Mounting Style Pendant Wall Ceiling Stanchion DIODE POLARIZED EXPLOSIONPROOF STEADY-ON BEACONS EXDSO301A/24 28 24–28VDC Amber 3R, 4X, Marine EXDSO301B/24 28 24–28VDC Blue 3R, 4X, Marine EXDSO301C/24 28 24–28VDC Clear 3R, 4X, Marine EXDSO301G/24 28 24–28VDC Green 3R, 4X, Marine EXDSO301M/24 28 24–28VDC Magenta 3R, 4X, Marine EXDSO301R/24 28 24–28VDC Red 3R, 4X, Marine Temperature Performance Data EXSO Series Steady-On Beacon Voltage 120VAC EXDSO Series Steady-On Beacon — Diode Polarized Voltage 24-28 VDC 946 STIBOINFO((CRH:66008com:11L:946)) CH0 0 4 F - 5 US: 1-866-764-5454 Ambient Max. Temp. 40°C 55°C 65°C 40°C 55°C 65°C CAN: 1-800-265-0502 Supply Wire 75°C 90°C 105°C 75°C 90°C 105°C Class I Div. 1, 2 Group C, D Class I, Zone 1 Group II B T6(85°C) T5(100°C) T5(100°C) T6(85°C) T6(85°C) T6(85°C) Class II, Class III Div. 1 Group E, F, G T4A(120°C) T4(135°C) T4(135°C) T4A(120°C) T4(135°C) T4(135°C) Copyright© 2006 Cooper Crouse-Hinds Class II, Class III Div. 2 Group F, G T4A(120°C) T4(135°C) T4(135°C) T4A(120°C) T4(135°C) T4(135°C) Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0947-7 Name: 11L-947 100: DATE: JAN 19 2006 Time: 6:03:01 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G ɀ Class III UL 1638, 1203 and 844 Listed 1598A Marine Listed NEMA 4X watertight, IP 66 HazardɀGard EX Series Visual Signaling Devices Explosionproof Rotating Beacons 11L Cooper Crouse-Hinds HazardɀGard EXR Series Explosionproof Rotating Beacons are designed for installation in hazardous locations, such as manufacturing plants, heavy industrial facilities, refineries, chemical, petrochemical, pharmaceutical and off-shore drilling platforms. The units are UL listed for Type 3R, 4X and marine installations. The rotating beacons are available for pendant, wall, stanchion and ceiling mounts, and come in six different globe colors. The EXDR Series Explosionproof Rotating Beacon is diode polarized for use in standard 24–28VDC electrical circuits or in electrically supervised circuits. Electrically supervised circuits are typically used in life-safety or security applications. Under normal operation in an electrically supervised circuit, the diode is reversed biased, meaning it blocks voltage from being applied to the rotating beacon and prevents it from lighting. When a warning detecting device is activated, the diode’s polarity is reversed through a circuit panel. The diode becomes forward biased, allows voltage to the device and activates the rotating beacon. Primary Applications ɀ Security alert ɀ Obstacle warning ɀ Areas under construction or off limits Certifications and Compliances ɀ Equipment obstruction warning ɀ Status indication of a process ɀ Supplement audible signaling Typical Industries ɀ Utility gas plants ɀ Wastewater treatment plants ɀ Chemical plants ɀ Pharmaceutical plants ɀ Refineries ɀ Mining Key Features and Benefits ɀ Powerful halogen rotating beacon emits bright light to provide critical visual warning. ɀ Available in pendant, wall, stanchion and ceiling mount. ɀ Available in six different globe colors — amber, blue, clear, green, magenta and red. ɀ Beacon produces 75 rotations per minute. ɀ Factory sealed — No external seals required. ɀ Quick connect — Strobe fixture threads onto mounting module for easy installation. ɀ Class I, Division 1, Groups C & D ɀ Class II, Division 1, Groups E, F & G ɀ Class I, Zone 1 & 2, Group IIB ɀ Class III ɀ UL and cUL 1638, UL 1203 and UL 844 Listed ɀ 1598A Marine Listed ɀ NEMA 4X watertight, IP 66 Materials & Finishes ɀ Body, mounting modules and guard — Copper-free aluminum ɀ Globe — Heat and impact-resistant glass ɀ Gaskets — Silicone ɀ External hardware — Stainless steel ɀ Internal components — Solid-state electronics in a moistureresistant and heat-dissipating epoxy ɀ Epoxy powder coated for corrosion resistance Ratings ɀ 120VAC (EXR) and 24–28VDC (EXDR) ɀ Operating Current: 0.382 amps at 120VAC 0.8 amps at 24–28VDC ɀ Peak Candlepower: 3328 (EXR) 2838 (EXDR) Hub Size ɀ 3⁄4-inch NPT pendant, ceiling and wall mount ɀ 11⁄4-inch NPT stanchion mount US: 1-866-764-5454 STIBOINFO((CRH:66008com:11L:947)) CH0 0 4 F - 5 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 947 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0948-13 Name: 11L-948 11L DATE: JAN 19 2006 Time: 6:04:07 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G ɀ Class III UL 1638, 1203 and 844 Listed 1598A Marine Listed NEMA 4X watertight, IP 66 HazardɀGard EX Series Visual Signaling Devices Explosionproof Rotating Beacons Ordering Information STEP 2 Order Mounting Module STEP 1 Order Rotating Beacon Type Catalog Lens Number Voltage Color EXPLOSIONPROOF ROTATING BEACONS EXR301A/120 120VAC Amber EXR301B/120 120VAC Blue EXR301C/120 120VAC Clear EXR301G/120 120VAC Green EXR301M/120 120VAC Magenta EXR301R/120 120VAC Red NEMA Rating Catalog Number EVMP2 EV22 & EV87 EV22 EVMJ4 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine Hub Size 3⁄4⍯ 3⁄4⍯ 3⁄4⍯ 11⁄4⍯ Mounting Style Pendant Wall Ceiling Stanchion DIODE POLARIZED EXPLOSIONPROOF ROTATING BEACONS EXDR301A/24 28 24–28VDC Amber 3R, 4X, Marine EXDR301B/24 28 24–28VDC Blue 3R, 4X, Marine EXDR301C/24 28 24–28VDC Clear 3R, 4X, Marine EXDR301G/24 28 24–28VDC Green 3R, 4X, Marine EXDR301M/24 28 24–28VDC Magenta 3R, 4X, Marine EXDR301R/24 28 24–28VDC Red 3R, 4X, Marine Temperature Performance Data EXR Series Rotating Beacon Voltage 120VAC EXDR Series Rotating Beacon — Diode Polarized Voltage 24-28 VDC 948 STIBOINFO((CRH:66008com:11L:948)) CH0 0 4 F - 5 US: 1-866-764-5454 Ambient Max. Temp. 40°C 55°C 65°C 40°C 55°C 65°C CAN: 1-800-265-0502 Supply Wire 75°C 90°C 105°C 75°C 90°C 105°C Class I Div. 1, 2 Group C, D Class I, Zone 1 Group II B T6(85°C) T5(100°C) T5(100°C) T6(85°C) T6(85°C) T6(85°C) Class II, Class III Div. 1 Group E, F, G T4A(120°C) T4(135°C) T4(135°C) T4A(120°C) T4(135°C) T4(135°C) Copyright© 2006 Cooper Crouse-Hinds Class II, Class III Div. 2 Group F, G T4A(120°C) T4(135°C) T4(135°C) T4A(120°C) T4(135°C) T4(135°C) csm no.: 100 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0949-19 Name: 11L-949 DATE: JAN 19 2006 Time: 6:04:08 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name HazardɀGard EX Series Visual Signaling Devices csm no.: 100 11L Dimensions & Weights Stanchion Mount NET LUMINAIRE WEIGHTS US: 1-866-764-5454 STIBOINFO((CRH:66008com:11L:949)) CH0 0 4 F - 5 Luminaire Housing with Guard 11.0 lbs. Add mounting modules Pendant Ceiling Wall Stanchion 1.0 lbs. 1.0 lbs. 4.5 lbs. 2.5 lbs. CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 949 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0950-2 Name: 11L-950 11L 100: DATE: JAN 19 2006 Time: 6:04:09 PM Operator: JB COLOR: CMYK TCP: 15001 ɀ ɀ ɀ ɀ Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Group IIC ɀ Cl. II, Div 2, Groups F, G; Cl. III VDAS Strobe Lights Warning and Visual Indication Application: Typedriver Name: TS name csm no.: 100 Wet Locations 3, 3R, 4, 4X CSA Enclosure 3, 4, 5 Replacement Parts VDAS strobe lights are used: ɀ in areas with high noise levels ɀ to visually indicate warnings or hazards Electronic Strobe Subassembly (includes flash tube): 120 VAC. . . . . . . . . . . . . . . . . . . . . . CHTFI-120H 240 VAC . . . . . . . . . . . . . . . . . . . . . CHTFI-240H 12 VDC . . . . . . . . . . . . . . . . . . . . . . . . CHTFI-012 24 VDC. . . . . . . . . . . . . . . . . . . . . . . . CHTFI-024 Flash Tube . . . . . . . . . . . . . . . . . . . . . . . . RSTC Globe Assembly Clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/C Red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/R Green . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/G Amber . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/A Blue. . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/B Features: ɀ Reliable solid state components. ɀ Compact enclosure design provides 60 high intensity flashes per minute. ɀ Choice of globe colors to meet various requirements. ɀ Gasketed to seal out dirt and liquids. ɀ Designed for globe up or globe down applications. ɀ Easy to install. ɀ Lightweight corrosion-resistant copper-free aluminum construction. ɀ Conduit locking hub for increased safety and security. Standard Materials: ɀ Body – copper-free aluminum ɀ Globe – LEXAN® fresnel lens Ordering Information Standard Finishes: Globe Color ɀ Body – gray epoxy Size Range: Red Blue Amber Green Clear ɀ 3⁄4⍯ conduit Certifications and Compliances: ɀ NEC and CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2, IIC ɀ UL Standards 844 1598 Luminaires ɀ CSA Standards C22.2 No. 137 Pendant Hub Size 3⁄4⍯ 3⁄4⍯ 3⁄4⍯ 3⁄4⍯ 3⁄4⍯ Cat. # 120 VAC VDAS/R VDAS/B VDAS/A VDAS/G VDAS/C Temperature Performance Data: Ambient °C 40° 55° 65° Electrical Ratings: Class I Div 2 T3B T3A T3 Cat. # 240 VAC VDAS/R/240 VDAS/B/240 VDAS/A/240 VDAS/G/240 VDAS/C/240 Dimensions Class II Div 2, Class III T3B ----- ɀ 120, 240 VAC 50/60 Hz ɀ 12, 24 VDC Photometric Data, Clear Globe ɀ Peak flash – 3.45 million candlepower ɀ Effective candlepower (light intensity if light is burning steadily) – 201 ECP Photometric Data: Globe Color Output Intensity Clear . . . . . . . . . . . . . . . . . . . . . . . 201 ECP Red . . . . . . . . . . . . . . . . . . . . . . . . . 46 ECP Amber. . . . . . . . . . . . . . . . . . . . . . 152 ECP Blue. . . . . . . . . . . . . . . . . . . . . . . . . 38 ECP Green . . . . . . . . . . . . . . . . . . . . . . . 38 ECP Operating Current: Voltage 120 VAC 240 VAC 12 VDC 24 VDC 950 STIBOINFO((CRH:66008com:11L:950)) CH0 1 1 L - 8 Operating Current .3A .15A .9A .45A US: 1-866-764-5454 CAN: 1-800-265-0502 Cat. # 12 VDC VDAS/R/012 VDAS/B/012 VDAS/A/012 VDAS/G/012 VDAS/C/012 Copyright© 2006 Cooper Crouse-Hinds Cat. # 24 VDC VDAS/R/024 VDAS/B/024 VDAS/A/024 VDAS/G/024 VDAS/C/024 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0951-4 Name: 12L-951 DATE: JAN 19 2006 Time: 6:04:10 PM Operator: RB COLOR: CMYK TCP: 15001 Specialty Lighting Typedriver Name: TS name csm no.: 100 12L Tank, Task and Gauge Lighting Hazardous and Non-Hazardous Locations Description Page No. Application/Selection 952 Gauge Light 958 Tank Light 953, 954 V160 EVA160 Task Light 955-957 EVTL1B50 EVTL1L50 US: 1-866-764-5454 STIBOINFO((CRH:66008com:12L:951)) CH0 0 0 0 2 L CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 951 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0952-4 Name: 12L-952 12L 100: DATE: JAN 19 2006 Time: 6:04:11 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Specialty Lighting Tank, Task and Gauge Hazardous and Non-Hazardous Locations Application and Selection Application: Specialty lighting luminaires are used: ɀ for various task lighting requirements in locations that are hazardous (classified) due to the presence of combustible dusts or easliy ignitible fibers and flyings ɀ in areas where conventional lighting is not acceptable due to size and/or location ɀ in locations where an adequate light source is necessary for tank, instrument, and gauge applications ɀ in manufacturing plants, refineries, pharmaceutical, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, grain processing and handling facilities and other heavy industrial applications 952 STIBOINFO((CRH:66008com:12L:952)) CH0 2 L - 1 2 Considerations for Selection: Environmental: ɀ What is the hazardous area classification (NEC)/(CEC) of the location in which the luminaire will be installed? Lighting levels required: ɀ What wattage luminaire(s) will provide the desired light level (See lighting Selector Guide, pages 665 through 689, to determine number and location of fixture required). Physical Arrangement: ɀ Type of fixture mounting needed. US: 1-866-764-5454 CAN: 1-800-265-0502 Product Selection: ɀ EV Tank Lights are suitable for use in Class I, Groups C, D hazardous (classified) locations. Tank lights are used to light the inside of tanks, vats, process vessels, etc. ɀ EVTL Explosionproof Task Lights are suitable for use in Class I, Group B, C, D and Class II, Groups E, F, G hazardous (classified) locations. EVTL Lights are ideal for applications in which water spray and corrosive atmospheres are considerations. ɀ ELG gauge lights are suitable for use in Class I, Groups C, D hazardous (classified) locations. The light is used to illuminate liquid level gauges and to direct the light over the length of the column. Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0953-2 Name: 12L-953 DATE: JAN 19 2006 Time: 6:04:12 PM Operator: JB COLOR: CMYK TCP: 15001 Watertight V Observation Incandescent Luminaire Typedriver Name: TS name csm no.: 100 12L Application: The incandescent V observation luminaire is used: ɀ in tanks or kettles where food is processed ɀ to light the inside of tanks for observation of the contents through a window Features: ɀ Watertight ɀ Supported by a mounting ring which contains holes for riveting when placed around a hole in the tank. It can also be welded or brazed to the tank. ɀ Heavy heat and impact-resistant glass globe eliminates breakage and resultant contamination of food from glass particles ɀ Relamping is easily accomplished by removal of the two thumb-screws which fasten the body to the mounting ring ɀ The flexible cord or cable should be connected by an EC flexible coupling or CG Series connector Standard Materials: ɀ Mounting ring – silicon bronze ɀ Fixture body – Feraloy® iron alloy ɀ Globe – heat-resisting glass Furnished with EV10 Globe, and C166 Medium Base Lamp Receptacle Hub Lamp Size 1⁄2 Standard Finishes: Feraloy – electrogalvanized and aluminum acrylic paint ɀ Bronze – natural Size 50, 60, 75 or 100W, A-21 Cat. # V160 Dimensions Size Ranges: ɀ Up to 100 watt, A-21 lamp Certifications and Compliances: ɀ UL Standard: 1571 ɀ CSA Standard: C22.2 US: 1-866-764-5454 STIBOINFO((CRH:66008com:12L:953)) CH0 1 L - 1 9 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 953 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0954-2 Name: 12L-954 12L DATE: JAN 19 2006 Time: 6:04:13 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups C, D Cl. I, Zone I & 2 IIB Cl. II, Div. 1, Groups E, F, G – EVO only EV Tank Luminaires Application: Dimensions EV tank light luminaires are used: ɀ to light inside of tanks, vats, process vessels, etc. ɀ in chemical plants, petrochemical plants and petroleum process industries ɀ suspended over tank porthole by EC flexible hanger (EVO style) ɀ mounted directly in tank wall (EVA) EVO2376 Features: ɀ High light output ɀ Compact design EVA160: ɀ Furnished with tank ring having eight 3⁄16⍯ holes for riveting to tank ɀ Can be brazed if desired ɀ Luminaire ring is attached to the tank ring by eight 1/4-20 Allen Head cap screws ɀ Luminaire attached to luminaire ring by four wing screws ɀ EC flexible luminaire support should be used so relamping can be accomplished without disturbing the globe EVO2376 EVA160 Standard Materials: ɀ Bodies – EVA: Receptacle housing and intermediate ring – Feraloy® iron alloy. Tank ring – silicon bronze; EVO: copper-free aluminum ɀ Globes: EVA – glass, heat and impact resistant; EVO – glass, heat strengthened plate glass Standard Finishes: ɀ Feraloy iron alloy – cadmium electrogalvanized and aluminum acrylic paint; copper-free aluminum – aluminum acrylic paint; silicon bronze – natural EVA160 ɀ 1⁄2⍯ and 3⁄4⍯ hubs Watts 75 Capacity Ranges: 100, A-21 Size Ranges: ɀ EVO – 75 watt, reflector spot max. ɀ EVA – 100 watt, A-21 max. Lamp (not furnished) 75R 30/SP reflector spot (medium base) Medium base Certifications and Compliances: Hub Size 1⁄2 & 3⁄4 Cat. # EVO2376 1⁄2 EVA160 Tank Ring Mounting (EVA160) ɀ NEC: Class I, Division 1 and 2, Groups C, D – EVO and EVA Class II, Division 1, Groups E, F, G – EVO only ɀ UL Standard: 844 Temperature Performance Data: (based on 40°C Ambient) Class I Class II Groups C, D Groups E, F, G EVO2376 T3C T3C EVA160 T3C* — *All mounting positions 954 STIBOINFO((CRH:66008com:12L:954)) CH0 2 L - 1 2 Supply Wire (°C) 75 75 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0955-4 Name: 12L-955 DATE: JAN 19 2006 Time: 6:04:14 PM Operator: JB COLOR: CMYK EVTL Explosionproof Task Light Class I Groups B, C, D Class I Zone I, IIB+H2 Class II Groups E, F, G Class III Simultaneous Service TCP: 15001 Typedriver Name: TS name csm no.: 100 Wet Locations Marine Locations NEMA 3, 3R, 4, 4X 12L Application EVTL task light luminaires are used: ɀ For various task lighting requirements in locations that are hazardous (classified) due to the presence of flammable gases or vapors, combustible dusts or easily ignitible fibers & flyings. ɀ in marine applications where water spray and corrosive atmospheres are considerations. ɀ in areas where conventional lighting is not acceptable due to size and/or location. ɀ in locations where an adequate light source is necessary for tank, instrument, and gauge applications. ɀ in porthole or sightglass applications where a spotlight is required for visibility inside tanks, vats and process vessels. ɀ in manufacturing plants, refineries, pharmaceutical, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, grain processing and handling facilities and other heavy industrial applications. EVTL1B50 EVTL1L50 Key Features Benefits Class I, II, III, Simultaneous Presence Suitable for most hazardous (classified) areas ɀ Housing—Copper-free aluminum ɀ 3⁄4⍯ NPT hub and plug—Aluminum ɀ Mounting bracket(s) and External hardware— Stainless Steel ɀ Gasket—Silicone rubber ɀ Lens—Heat and impact resistant clear glass Class I Group B standard Suitable for areas containing hydrogen Wet and Marine (NEMA 4X) Suitability Perfect for hose down applications 55° ambient suitability Standard Finishes: Addresses higher ambients typical of industrial plants. Superior corrosion resistance Cast copper-free aluminum housing with Corro-free TM epoxy powder coat finish. Stainless steel mounting Superior corrosion resistance brackets and hardware. Two mounting styles bracket Maximize mounting flexibility and leg ɀ Bracket (Universal) Ceiling, Wall or Base mounting ɀ Leg (Site Glass) Site Glass mounting Uses standard 50 watt PAR 20 Improved light output, economical, long life medium base 120V lamps 2000-2500 hour light source Uses 50PAR20 130V lamps for Increase lamp life to 5000+ hours while added lamp life maintaining 76% lumen output 50PAR20 lamps available in both Vary the illumination characteristics by simply flood and spot light patterns changing lamps Easy access interior Reduced maintenance and lamp replacement time Seal within 5 ft. (not 18⍯) of Provides greater flexibility in seal location luminaire Standard Materials: ɀ Aluminum housing (exterior)—Corro-free epoxy powder coat ɀ Stainless Steel—Natural Ratings (Electrical/Size) Source/Wattage (Medium Base Lamps) ɀ 50PAR20 type—50W 120V halogen parabolic reflector. Lamp life 2000-2500 hrs. ɀ 130V lamps available to extend lamp life to 5000+ hrs. Voltage ɀ 120V 60 Hz Hub Size ɀ (1) 1⁄2⍯ NPT ɀ For through feed, use EVTL-TF1 Certifications and Compliances: ɀ NEC/CEC ɀ ɀ ɀ ɀ ɀ ɀ ɀ Class I Division 1 & 2 Groups B, C, D Class II Group E, F, G Class III Class I Zone 1 & 2 Group IIB + H2 Wet locations Marine locations NEMA 4X ɀ NEC Ordering Information: Luminaire Cat. # EVTL1B50 EVTL1L50 Conduit Entry 1⁄2⍯ 1⁄2⍯ 844—Hazardous (Divisions Classified) Locations 1571—Ordinary and Wet Locations, Marine Outside Type CSA Standards Wattage 50 50 Temperature Performance Data: ɀ Simultaneous Presence UL Standards Mounting Style Bracket (Universal) Leg (Site Glass) Catalog Number EVTL1B50 EVTL1L50 °C 40 40 Maximum Ambient Class I, Div, 1, B, C, D Class II, Div. 1, E, F, G Class III Simultanenous Presence Class I, Zone 1, IIB + H2 T3B T3B Supply Wire °C 85 85 C22.2 No. 137 Note: Install luminaire within aiming ranges shown on nameplate (See Dimensions) US: 1-866-764-5454 STIBOINFO((CRH:66008com:12L:955)) CH0 2 L - 1 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 955 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0956-3 Name: 12L-956 12L 100: DATE: JAN 19 2006 Time: 6:04:15 PM Operator: JB COLOR: CMYK EVTL Explosionproof Task Light TCP: 15001 Dimensions and Weights Aiming Range Dimensions: Bracket Mount Dimensions: Leg Mount Net Luminaire Weights (lbs) Luminaire Catalog Weight (lbs.) EVTL1B50 7 EVTL1L50 7 EVTL-TF1 1⁄2 956 STIBOINFO((CRH:66008com:12L:956)) CH0 2 L - 1 2 US: 1-866-764-5454 CAN: 1-800-265-0502 Typedriver Name: TS name csm no.: 100 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0957-3 Name: 12L-957 100: DATE: JAN 19 2006 Time: 6:04:16 PM Operator: JB COLOR: CMYK EVTL Explosionproof Task Light TCP: 15001 Photometric Data: Typedriver Name: TS name csm no.: 100 12L Lamp Light Distribution – (Philips lamp data shown. Similar for other manufacturers) Data shown is for 120 volt lamps For 130 volt lamps adjust data using a .76 multiplier US: 1-866-764-5454 STIBOINFO((CRH:66008com:12L:957)) CH0 2 L - 1 0 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 957 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRMAIN06-0958-5 Name: 12L-958 12L DATE: JAN 19 2006 Time: 6:04:17 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Cl. I, Div. 1 & 2, Groups C, D Cl. 1, Zone 1 & 2 IIB Explosionproof ELG Gauge Luminaires Application: ELG Gauge lights are used: ɀ in hazardous areas to illuminate liquid level gauges over entire length of gauge ɀ clamped to rear of liquid level gauge and conduit is attached to the ELG hubs. Light is reflected by Lucite reflector along the entire length of the gauge. Liquid level shows on front of gauge. All light is concentrated on liquid column – no spill light. Features: ɀ Even illumination over entire length of gauge ɀ Variety of sizes to fit many gauges ɀ Several lights can be used in tandem to illuminate long gauge Standard Materials: ɀ Body – copper-free aluminum ɀ Reflectors – plexiglass Standard Finishes: ɀ Body – electrogalvanized and aluminum acrylic paint ELG329 with LE49 reflector Size Ranges: ɀ 1⍯ conduit through feed Dimensions Capacity Ranges: ɀ 120V medium screw base ‘‘A19’’ style incandescent lamp 58W maximum ɀ 25 watt – medium base – 1000 hour life ɀ 52 watt – medium base – 2500 hour life ɀ 58 watt – medium base – 3000 hour life Certifications and Compliances: ɀ NEC/CEC: Class I, Division 1 and 2, Groups C, D Ordering Information: Description Gauge Light (less reflector) Reflector – Short style Reflector – Long style Temperature Performance Data: (based on 40°C ambient) 58 Watt – T4A Maximum Catalog No. Length (L) (inches) ELG329 LE34 LE35 LE46 LE47 LE48 LE49 LE410 LE412 LE413 — 41⁄2 51⁄2 13 15 17 193⁄4 22 251⁄4 263⁄4 Plexiglass reflectors Short style Long style Options: Suffix to be Description Added to Cat. No. ɀ Group B suitability . . . . . . . . . . . . . . . . . . GB Suggested Lamps (Lamps not furnished) Manufacturer General Electric Osram/Sylvania Philips 958 STIBOINFO((CRH:66008com:12L:958)) CH0 2 L - 1 1 25 Watt 25A 25A 25A Catalog Number 52 Watt 58 Watt 60A/52WMP/98 60A/52/SS/XL 58A19/62 60A-52A/99/EW US: 1-866-764-5454 Volts 120 120 120 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds Zoom: 100
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-702 Modify Date : 2010:02:11 15:31:08+07:00 Create Date : 2010:02:11 15:30:29+07:00 Metadata Date : 2010:02:11 15:31:08+07:00 Creator Tool : Adobe Acrobat 6.0 Format : application/pdf Document ID : uuid:c59660bc-fc16-4f00-800f-1288691192f6 Instance ID : uuid:c9db375b-ce5b-4fab-95ac-5c1df80e46c4 Producer : Acrobat Distiller 6.0.1 for Macintosh Has XFA : No Page Count : 298 Creator : Adobe Acrobat 6.0EXIF Metadata provided by EXIF.tools