Control Products

Contents

Pages

What’s New . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/3
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/4
NEMA & General Purpose Control
Manual Control
Fractional HP Starters, Class SMF . . . . . . . . . . . . . . . . . . . . . . . . . . .8/5 – 8/6
Switches, Class MMS and MRS . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/7 – 8/8
Starters and Switches, Class 11 - 3RV . . . . . . . . . . . . . . . . . . . . . . .8/9 – 8/10
NEMA Control
Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/11
Non-Combination Starters Features and Benefits . . . . . . . . . . . . .8/12 – 8/13
Non-Reversing Starters, Class 14 . . . . . . . . . . . . . . . . . . . . . . . . . .8/14 – 8/16
Combination Starters Features and Benefits . . . . . . . . . . . . . . . . . . . . . .8/17
Combination Starters, Class 17 and 18 . . . . . . . . . . . . . . . . . . . . .8/18 – 8/26
Reversing Starters, Class 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/27 – 8/28
Combination Reversing Starters, Class 25 and 26 . . . . . . . . . . . . .8/29 – 8/30
Two Speed Starters Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . .8/31
Two Speed Starters, Class 30 . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/32 – 8/35
Combination Two Speed Starters, Class 32 . . . . . . . . . . . . . . . . . .8/36 – 8/43
Non-Reversing Contactors, Class 40 . . . . . . . . . . . . . . . . . . . . . . .8/44 – 8/45
Vacuum Contactors, Class 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/45
Reversing Contactors, Class 43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/46
Overload Relays, Class 48, 958 and 3RB20 . . . . . . . . . . . . . . . . . .8/47 – 8/51
Duplex Controllers
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/52
Non Combination, Class 83 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/53
Combination, Class 84 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/54 – 8/55
Pump Control Panels
Irrigation, Class 81 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/56
Class 87 and 88 Features and Benefits . . . . . . . . . . . . . . . . . . . . .8/57 – 8/58
Full-Voltage Type, Class 87 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/59 – 8/60
Vacuum Starter Type, Class 87 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/61
Reduced-Voltage Type, Class 88 . . . . . . . . . . . . . . . . . . . . . . . . . .8/62 – 8/63
Reduced Voltage Control
Reduced Voltage Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . .8/64
Auto Transformer Starters, Class 36 and 37 . . . . . . . . . . . . . . . . . . . . . . .8/65
Part Winding Starters, Class 36 and 37 . . . . . . . . . . . . . . . . . . . . . . . . . . .8/66
Wye Delta Open Transition, Class 36 and 37 . . . . . . . . . . . . . . . . . . . . . .8/67
Wye Delta Closed Transition, Class 36 and 37 . . . . . . . . . . . . . . . . . . . . .8/68
Lighting Control
Electrically Held Contactors, Class LE . . . . . . . . . . . . . . . . . . . . . .8/69 – 8/71
Mechanically Held Contactors, Class CLM . . . . . . . . . . . . . . . . . .8/72 – 8/74
Control Power Transformers
Domestic and International (UL, CSA and CE),
Class MT and MTG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/75 – 8/79

Siemens Industry, Inc.
Industrial Controls Catalog

8/1

Control Products

Contents

Pages

Modifications and Drawings
Field Modification Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/80 – 8/90
Enclosure Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/91 – 8/94
Factory Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/95 – 8/99
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/100 – 8/129
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/130 – 8/149
Heater Tables and Replacement Parts
Overload Relay Heater Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/150 – 8/156
NEMA Coils and Contact Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/157 – 8/158
Coil VA Ratings and Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/159
Lighting Contactor Parts and Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/160 – 8/161

8/2

Siemens Industry, Inc.
Industrial Controls Catalog

Control Products
What’s new
Irrigation Pump Panel
with Solid State
Overload, Class 81
Siemens introduces its
new Class 81 Irrigation
Pump Panel. This newest
addition to the already
extensive line of Siemens
pump panels was designed
specifically for the agricultural market. It is well suited for irrigation and similar
pumping applications and is
built to withstand the
harsh elements of the
outdoors. Refer to page
8/56 for more details and
selection.

ESP200™ Solid State Overload Relay
Building and improving on past successes, self-powered
ESP200 overload relays are a revolution for both industrial and
construction applications.
Ideal for oil pumping, agriculture, OEM operations and any
other industrial applications where motor life is monitored and
single-phase protection is important, NEMA starters equipped
with ESP200 are both versatile and rugged.
Refer to page 8/47 for more details and information.

Siemens Industry, Inc.
Industrial Controls Catalog

8/3

Control Products

NEMA & General Purpose Controls
Product Overview

Class SMF
Fractional Horsepower
Manual Starters
Page 8/5

Class MMS & MRS
Fractional Horsepower
Manual Switches
Page 8/7

Class 11
Manual Starters and
Switches
Page 8/9

Class 22
NEMA Reversing
Starters
Page 8/27

Class 25, 26
NEMA Combination
Reversing Starters
Page 8/29

Class 30
NEMA Multi-Speed
Starters
Page 8/32

Class 40
NEMA Contactors
and Vacuum Contactors
Page 8/44

Class 43
NEMA Reversing
Contactors
Page 8/46

Class 48, 958, 3RB20
Overload Relays
Page 8/47

Class MT, MTG
Control Power
Transformers
Page 8/75

Modifications and
Drawings
Page 8/80

Heater Tables and
Replacement Parts
Page 8/150

8/4

Class 14
NEMA Starters
Page 8/14

Class 32
NEMA Combination
Multi-Speed Starters
Page 8/36

Class 81, 83, 84,
87, 88
Pump Controls
Page 8/53

Class 17, 18
NEMA Combination
Starters
Page 8/18

Class 36, 37
Reduced Voltage
Electromechanical
Starters
Page 8/64

Class LE, CLM
Lighting Contactors
Page 8/69

Siemens Industry, Inc.
Industrial Controls Catalog

Manual Control

Fractional HP Starters, Class SMF
General

Class SMF
Class SMF fractional horsepower
starters provide overload protection as
well as manual on-off control for small
horsepower motors in a variety of
industrial and commercial applications.
Available in one or two pole versions,
these devices are suitable for use with
AC single phase motors up to 1 HP.
Two pole starters can also be used
with DC motors up to 3⁄4 HP. Typical
applications include fans, conveyors,
pumps, and small machine tools.

Continuous Current Rating
16 amperes.
Overload Trip Assembly
Motor protection is provided by a Class
SMFH heater element which must be
installed before the starter will operate.
Two Speed Starters
Two speed manual starters are
designed for control of small single
phase AC motors having separate
windings for high and low speed
operation. Two toggle operated starters
are used, with overload protection
included for each motor winding.
Surface mounting devices, and those
with a gray flush plate, utilize a
mechanical interlock which allows
direct control of the motor by means
of the toggle operators.

Enclosures
Class SMF, NEMA Type 1 surface
mounting enclosures are sheet steel
with a thermo-plastic wrap-around cover
for convenience in wiring. The NEMA
Type 1 enclosure is also available in an
oversized version which allows more
wiring space. A zinc alloy die casting is
used for NEMA Type 4 enclosures.
Pilot Lights
Red or green neon pilot light units
are available for flush mounting plates,
NEMA Type 1 enclosures, and NEMA
Type 4 enclosures. Pilot lights may be
either factory or field installed. (For
starters that contain a pilot light, a Red
light is standard. For a Green pilot light
add ”G” to the end of the catalog
number.)
Terminals
Binding head screw type terminals are
suitable for #10 or smaller copper wire,
and are accessible from the front. All
terminals are clearly marked.
Mounting
Open types without a pilot light fit
standard single gang switch boxes, and
can be used with any cover plate having
a standard toggle cutout. Single-unit
flush mounting types, including those
with pilot lights, are suitable for wall
mounting in a standard switch box or
for machine cavity mounting without
a box.
Operation
Available with toggle handle or with
removable key type operator to
discourage unauthorized operation.

Siemens Industry, Inc.
Industrial Controls Catalog

Class SMF Starter in a NEMA Type 1
Enclosure with Pilot Light

Emergency Off Actuator
A toggle operator extender is available
for Class SMF, NEMA Type 1 surface
mounted units. The extender has a red
vinyl button that provides a fast and
easy method for locating and switching
the device‘s toggle operator into the
OFF position. The Emergency Off
Actuator is available in kit form only
for field installation.
Handle Guard/Lock-Off
An optional handle guard on Class
SMF, NEMA Type 1 enclosed starters
prevents accidental operation of the
toggle operator and also allows the
toggle operator to be padlocked in
either the “ON” or “OFF” position.
This handle guard can be factory
installed on NEMA Type 1 enclosed
starters and is also available in kit form
for field installation on NEMA Type 1
surface and flush mounting enclosures.
Standard NEMA Type 4 metallic
enclosures include provisions for
padlocking the device in the
OFF position.

8/5

Manual Control

Fractional HP Starters with Melting ALloy Overload, Class SMF
Selection
Ordering Information

Horsepower Ratings
Maximum Horsepower

Heater Elements see page 8/150.
䊳 Field Modification Kits see page 8/80.
䊳 Dimensions see page 8/100.
䊳 Wiring Diagrams see page 8/130.
䊳

AC Single Phase

DC

1-Pole

2-Pole

2-Pole

115–230

1

1

34

277

1

1

—

Volts

Class SMF Starter in a NEMA Type 1
Enclosure with Pilot Light

⁄

Starter—Class SMF, Single Phase
General Purpose Flush Mounting
Open Starter with Flush Plate
(No Enclosure Provided)
Standard
Stainless
Steel
Flush Plate

Gray
Flush
Plate

NEMA Type 1 General Purpose
Enclosure, Surface Mounting

Jumbo
Stainless
Steel
Flush Plate

Type
Open Type
of
No. of
Catalog List Catalog List Catalog List Catalog
Operator Poles Starter Features Number Price $ Number Price $ Number Price $ Number
Standard
Red Pilot Light
Standard
Red Pilot Light
Standard
Red Pilot Light
Standard
Red Pilot Light

1
Toggle
2
1
Key
2

SMFF01
SMFF01P
SMFF02
SMFF02P
SMFF03
SMFF03P
SMFF04
SMFF04P

SMFFF1
SMFFF1P
SMFFF2
SMFFF2P
SMFFF3
SMFFF3P
SMFFF4
SMFFF4P

SMFFS1
SMFFS1P
SMFFS2
SMFFS2P
SMFFS3
SMFFS3P
SMFFS4
SMFFS4P

Standard

List
Catalog
Price $ Number

—
SMFFSJ1P
—
SMFFSJ2P
—
SMFFSJ3P
—
SMFFSJ4P

—
—
—
—

NEMA Type
3R, 4 & 12

NEMA
Type 4

Watertight,
Dust-tight
Metallic
Enclosure
with Clear Cover

Watertight,
Dust-tight
Metallic
Enclosure

NEMA Type
3R, 7 & 9
Div 1 and Div 2
Class I Groups
B, C, D &
Class II Groups
E, F, G
Enclosures

Oversized
List Catalog
Price $ Number

List
Catalog
Price $ Number

List
Catalog
Price $ Number

List
Catalog
Price $ Number

—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—

List
Price $

SMFFG1
SMFFG1P
SMFFG2
SMFFG2P
SMFFG3
SMFFG3P
SMFFG4
SMFFG4P

SMFFGJ1
SMFFGJ1P
SMFFGJ2
SMFFGJ2P
SMFFGJ3
SMFFGJ3P
SMFFGJ4
SMFFGJ4P

SMFFWN1
SMFFWN1P
SMFFWN2
SMFFWN2P
SMFFWN3
SMFFWN3P
SMFFWN4
SMFFWN4P

—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—

SMFFG5
SMFFG5P
—
—

SMFFGJ5
SMFFGJ5P
—

—

—
—
—

—
—
—

SMFFW1
SMFFW1P
SMFFW1H

SMFFR1
—
—
SMFFR1H

—

—

—

—

—

SMFFW1PH

—

Starter With Handle Guard/Lock-Off—Class SMF, Single Phase
Standard
Red Pilot Light
(2) 3⁄4" NPT Outlets
(2) 3⁄4" NPT Outlets
and Red Pilot Light
Standard
Red Pilot Light
(2) 3⁄4" NPT Outlets
(2) 3⁄4" NPT Outlets
and Red Pilot Light

1
Toggle
2

—
—
—

—
—
—







—
—
—

—

—



—

—
—
—

—
—
—




—
—
—



—

—



—









—
—
—



—
—
—



—



—



—
—
—




—
—
—

SMFFG6
SMFFG6P
—
—

SMFFGJ6
SMFFGJ6P
—



—



—

—

—









One Starter in Duplex Enclosure—Class SMF, Single Phase

—

—



—


—

—
—
—

—
—
—

SMFFW2
SMFFW2P
SMFFW2H

SMFFR2
—
—
SMFFR2H

—

—

—

SMFFW2PH

—

—



General Purpose Flush Mounting
Open Starter with Flush Plate - (No Enclosure Provided)

Type of
Operator

Number
of Poles

Toggle

2

Key

2

Starter Features
Standard
Red Pilot Light
Red Pilot Light

Gray Flush Plate
For Wall or Cavity
Mounting

Stainless Steel Flush
Plate for Wall or Cavity
Mounting

NEMA Type 1 General
Purpose Enclosure
Surface Mounting

Catalog Number
—
—
—

Catalog Number
—
—
—

List Price $
—
—
—

Catalog Number List Price $
SMFFG02
SMFFG02P
SMFFG04P

—
SMFFS22P
SMFFS44P

—

SMFFG222
SMFFG222P
SMFFG44P

List Price $
—
—
—

Replacement
Starters
Catalog Number
—
—
—

List Price $
—
—
—

Two Starters In Duplex Enclosure—Class SMF, Single Phase
Toggle

2 Per Starter

Key

2 Per Starter

Standard
Red Pilot Light on Each Starter
Red Pilot Light on Each Starter

SMFFF222
SMFFF222P
SMFFF44P

—
—
—

—
—
—

—
—
—
—
—

—
—
—
—
—

SMFF01T
SMFF01PT

Starter And “Auto-Off-Hand” SPDT Selector Switch (AC Only)—Class SMF, Single Phase
1
Toggle
2
Key

2

Standard
Red Pilot Light
Standard
Red Pilot Light
Red Pilot Light

SMFFF71
SMFFF71P
SMFFF72
SMFFF72P
SMFFF74P

—
SMFFS71P
—
SMFFS72P
SMFFS74P

—
—

SMFFG71
SMFFG71P
SMFFG72
SMFFG72P
SMFFG74P

—
—

—
—

SMFFG11
SMFFG11P

—
—

SMFFG22
SMFFG22P

Two Speed Starters (AC Only)—Class SMF, Single Phase
1
Toggle
2

Mechanical Interlock
Mechanical Interlock and (2) Red Pilot Lights
Mechanical Interlock, HIGH-OFF-LOW
Selector Switch and (2) Red Pilot Lights
Mechanical Interlock
Mechanical Interlock and (2) Red Pilot Lights
Mechanical Interlock, HIGH-OFF-LOW
Selector Switch and (2) Red Pilot Lights

 One heater element required.
 Furnished with (1) 3⁄4" NPT Outlet

in bottom

SMFFF11
SMFFF11P
—

—

SMFFF22
SMFFF22P
—

SMFFS101P
—
—

—

SMFFS202P

 Two heater elements required.
 Order Open Type starter plus separate

—

—

SMFF01PT
SMFF02T
SMFF02PT

—

SMFF02PT

 For

handle guard kit.

(reversible for top feed).

8/6

—

Product Category: NEMA

starters that contain a pilot light, a Red light is
standard. For a Green pilot light add ”G” to the end of
the catalog number.

Siemens Industry, Inc.
Industrial Controls Catalog

Manual Control

Fractional HP Switches, Class MMS, MRS
General

Class MMS, MRS

Enclosures

Class MMS and MRS motor starting
switches provide manual “ON-OFF”
control of single or three phase AC
motors where overload protection is
not required or is provided separately.
Compact construction and a 600 volt
rating make these switches suitable
for a wide range of industrial and
commercial uses. Typical applications
include small machine tools, pumps,
fans, conveyors and many other types
of electrical machinery. They can also
be used on non-motor loads such as
resistance heating applications.

Class MMS, MRS, NEMA Type 1
surface mounting enclosures are sheet
steel with a thermo-plastic wrap-around
cover for convenience in wiring.
The NEMA Type 1 enclosure is also
available in an oversized version which
allows more wiring space. A zinc alloy
die casting is used for NEMA Type 4
enclosures.

Continuous Current Rating
MMS & MRS: 30 amperes at 250
volts max, 26.4 amperes at 277 volts,
20 amperes at 600 volts max, 30
amperes resistive at 600 volts max.
Two Speed—Class MRS
Two speed manual switches may be
used with separate winding three phase
or single phase AC motors where
overload protection is not required or is
provided separately. Two switches are
employed to give “ON-OFF” control in
each speed.
Reversing—Class MRS
Reversing manual switches provide
a compact means of starting, stopping
and reversing AC motors where
overload protection is not required or
is provided separately. They are suitable
for use with three phase squirrel cage
motors and for single phase motors
which can be reversed by reconnecting
motor leads. Two switches are used,
one to connect the motor forward
rotation and one for reverse.

Siemens Industry, Inc.
Industrial Controls Catalog

Pilot Lights
Red or green neon pilot light units
are available for flush mounting plates,
NEMA Type 1 enclosures, and NEMA
Type 4 enclosures. Pilot lights may be
either factory or field installed. (For
switches that contain a pilot light, a Red
light is standard. For a Green pilot light
add ”G” to the end of the catalog
number.)
Terminals
Binding head screw type terminals are
suitable for #10 or smaller copper wire,
and are accessible from the front. All
terminals are clearly marked.
Mounting
Open types without a pilot light fit
standard single gang switch boxes, and
can be used with any cover plate having
a standard toggle cutout. Single-unit
flush mounting types, including those
with pilot lights, are suitable for wall
mounting in a standard switch box or
for machine cavity mounting without
a box.
Operation
Available with toggle handle or with
removable key type operator to
discourage unauthorized operation.

Class MMS Switch in a
NEMA Type 1 Enclosure

Emergency Off Actuator
A toggle operator extender is available
for Class MMS, MRS, NEMA Type 1
surface mounted units. The extender
has a red vinyl button that provides a
fast and easy method for locating and
switching the device‘s toggle operator
into the OFF position. The Emergency
Off Actuator is available in kit form
only for field installation.
Handle Guard/Lock-Off
An optional handle guard on Class
MMS, MRS, NEMA Type 1 enclosed
switches prevents accidental operation
of the toggle operator and also allows
the toggle operator to be padlocked in
either the “ON” or “OFF” position. This
handle guard is available in kit form for
field installation on NEMA Type 1
surface and flush mounting enclosures.
Standard NEMA Type 4 metallic
enclosures include provisions for
padlocking the device in the
OFF position.

8/7

Manual Control

Switches, Class MMS, MRS
Selection
Ordering Information

Horsepower Ratings

䊳

Heater Elements not Required.
Field Modification Kits see
page 8/80.
Dimensions see page 8/100.

䊳

Wiring Diagrams see page 8/130.

䊳
䊳

Device

Class MMS
Class MRS
Reversing
Class MMS
Two Speed

Class MMS Switch in a
NEMA Type 1 Enclosure

Maximum HP

No of
Poles

Motor Type
AC

2
3
2
3
2
3
3

Single Phase
3-Phase
Single Phase
3-Phase
Single Phase
3-Phase, Constant or Variable Torque
3-Phase, Constant Horsepower

115V

2
2
2
2
2
2
2

DC Ratings

230V

450–575V 90V

115V 230V

2
71/2
2
71/2
2
71/2
71/2

3
10
3
10
3
10
10

2
2
2
2
2
2
2

1
1
1
1
1
1
1

11/2
11/2
11/2
11/2
11/2
11/2
11/2

Switch—Class MMS, Single Phase and 3-Phase
General Purpose Flush Mounting
Open Switch with Flush Plate
(No Enclosure Provided)
Standard
Jumbo
Gray
Stainless
Stainless
Flush
Steel
Steel
Plate
Flush Plate
Flush Plate

Type
No
Open Type
of
of
Switch
Catalog
List Catalog
Operator Poles Features Number
Price $ Number
2

Toggle
3

2

Key

List Catalog
Price $ Number

Standard
MMSK01
Red Pilot Light
MMSK01A
115V AC

MMSKF1

MMSKS1

—

MMSKF1A

MMSKS1A

MMSKSJ1A

Red Pilot Light
MMSK01B
230V AC

MMSKF1B

MMSKS1B

MMSKSJ1B

Standard

MMSKF2

MMSKS2

—

Red Pilot Light

208-240V AC MMSK02B

MMSKF2B

MMSKS2B

MMSKSJ2B

Red Pilot Light
440-600V AC MMSK02C

MMSKF2C

MMSKS2C

MMSKSJ2C

Standard

MMSKF3

MMSKS3

—

Red Pilot Light
MMSK03A
115V AC

MMSKF3A

MMSKS3A

MMSKSJ3A

Red Pilot Light
MMSK03B
230V AC

MMSKF3B

MMSKS3B

MMSKSJ3B

MMSKF4

MMSKS4

—

MMSKF4B

MMSKS4B

MMSKF4C

MMSKS4C

MMSK02

MMSK03

Standard
MMSK04
Red Pilot Light
MMSK04B
208–240V AC

3

List Catalog
Price $ Number

Red Pilot Light MMSK04C
440–600V AC

NEMA Type 1 General Purpose
Enclosure Surface Mounting

NEMA Type
3R, 4 & 12

NEMA

Type 4

NEMA

Type 7 & 9

Watertight,
Dust-tight

Watertight,
Dust-tight
Metallic Enclosurer Metallic

with Clear Cover

Standard

List Catalog
Price $ Number

—

Class I Groups
B, C & D &
Class II Groups
E, F, G
Enclosures

Enclosure

Oversized
List Catalog
Price $ Number

List Catalog
Price $ Number

List
Catalog
Price $ Number

List
Catalog
Price $ Number

List
Price $

MMSKG1

MMSKGJ1

MMSKWN1

MMSKW1

MMSKR1

MMSKG1A

MMSKGJ1A

MMSKWN1A

MMSKW1A

—

—

MMSKG1B

MMSKGJ1B

MMSKWN1B

MMSKW1B

—

—

MMSKG2

MMSKGJ2

MMSKWN2

MMSKW2

MMSKR2

MMSKG2B

MMSKGJ2B

MMSKWN2B

MMSKW2B

—

—

MMSKG2C

MMSKGJ2C

MMSKWN2C

MMSKW2C

—

—

MMSKG3

MMSKGJ3

MMSKWN3

—

—

—

—

MMSKG3A

MMSKGJ3A

MMSKWN3A

—

—

—

—

MMSKG3B

MMSKGJ3B

MMSKWN3B

—

—

—

—

MMSKG4

MMSKGJ4

MMSKWN4

—

—

—

—

MMSKSJ4B

MMSKG4B

MMSKGJ4B

MMSKWN4B

—

—

—

—

MMSKSJ4C

MMSKG4C

MMSKGJ4C

MMSKWN4C

—

—

—

—

—

—

—

Reversing Switch—Class MRS, Single Phase and 3-Phase

Type of
Operator

Number of
Poles

Suitable
Motor Types

Switch Features (Including
Mechanical Interlock)

2

Single Phase
3-Lead
Repulsion-Induction

3

3-Phase; Also
Single Phase Capacitor,
Split Phase, or 4-Lead
Repulsion-Induction

Standard
Red Pilot Device—115V AC
Red Pilot Device— 230V AC
Standard
Red Pilot Light—110–120V AC
Red Pilot Light—208–220V AC
Red Pilot Light—440–600V AC

Toggle

General Purpose
Flush Mounting
NEMA Type 1
Open Switch with Flush Plate General Purpose
(No Enclosure Provided)
Enclosure Surface Mounting
Catalog Number List Price $ Catalog Number List Price $

MRSKF11
MRSKF11A
MRSKF11B
MRSKF22
MRSKF22A
MRSKF22B
MRSKF22C

MRSKG11
MRSKG11A
MRSKG11B
MRSKG22
MRSKG22A
MRSKG22B
MRSKG22C

Replacement Switch
Class MRS
Catalog Number List Price $

MRSK01T
MRSK01AT
MRSK01BT
MRSK02T
MRSK02AT
MRSK02BT
MRSK02CT

Two Speed Switch—Class MMS, Single Phase and 3-Phase

Type of
Operator

Suitable
Motor Types

Switch Features (Including
Mechanical Interlock)

2

Single Phase
Two Winding
(3-Lead)

3

3-Phase
Separate Winding
(Wye-Connected)

Standard
(2) Red Pilot Devices—115V AC
(2) Red Pilot Devices—230V AC
Standard
(2) Red Pilot Lights—208–240V AC
(2) Red Pilot Lights—440–600V AC

Number of
Poles

Toggle

 Manual switches do not include overloads.
 Furnished with (1) 3/4" NPT outlet in bottom

(reversible
for top feed). In order to obtain a 3⁄4" NPT outlet in top
and bottom, add suffix letter “H” to type number with
List Price adder.

8/8

General Purpose
Flush Mounting
NEMA Type 1
Open Switch with Flush Plate General Purpose
(No Enclosure Provided)
Enclosure Surface Mounting
Catalog Number List Price $ Catalog Number List Price $

MMSKF11
MMSKF11A
MMSKF11B
MMSKF22
MMSKF22B
MMSKF22C

 Do

not use as replacement interiors for NEMA Type 4
metallic enclosures. For replacement unit, order
Type MMSK01 or MMSK02 and separate pilot light kit.

Product Category: NEMA

MMSKG11
MMSKG11A
MMSKG11B
MMSKG22
MMSKG22B
MMSKG22C

Replacement Switch
Class MRS
Catalog Number List Price $

MRSK01T
MRSK01AT
MRSK01BT
MRSK02T
MRSK02BT
MRSK02CT

 For

switches that contain a pilot light, a Red light is
standard. For a Green pilot light add ”G” to the end
of the catalog number.

Siemens Industry, Inc.
Industrial Controls Catalog

Manual Control

Starters and Switches, Class 11 - 3RV
General

Class 11 - 3RV
Class 11 across the line manual
starters and switches provide control
for machinery where remote start stop
control is not required.
Class 11 - 3RV manual starters are
used for single and poly-phase motors
up to 20HP @ 575V. Starters have
bimetallic heater elements to provide
class 10 overcurrent protection. Each
starter has a fourth bimetallic strip that
reacts only to the ambient temperature
inside the control panel. This ambient
compensation helps prevent the starter
from nuisance tripping when the panel
temperature is higher than the ambient
temperature of the motor.
A built-in differential trip bar causes the
starter to trip faster on a phase loss
condition to help reduce motor damage.
Magnetic trip elements in each starter
take the device off line when it senses
current of 13 times the maximum FLA
dial setting.
Class 11 - 3RV switches provide
control for inherently protected motors.
Typical applications include metal and
woodworking machinery, grinders,
power saws, conveyors, fans, pumps,

OPEN TYPE
Starter

Siemens Industry, Inc.
Industrial Controls Catalog

blowers, textile and packaging
machinery, and paper cutters.
Each switch is provided with magnetic
trip elements which take the device off
line when it senses current of 13 times
the maximum switch rating.
Class 11 - 3RV manual starters can be
used as Type E self-protected manual
combination starters (up to 22 amps)
per UL508 or as components in
Group Installation per NEC 430.53.
When using the Class 11 - 3RV as a
manual combination starter upstream
protection is not required.
Class 11 - 3RV controllers are available
with low voltage protection which will
automatically open the power poles
when the voltage drops or the power
is interrupted.
Controllers with the LVP option provide
the OSHA requirements for protecting
personnel from potential injury caused
by the automatic start-up of machinery
following a voltage drop or power
interruption when low voltage
protection is specified.

NEMA 1
General Purpose

Class 11 - 3RV is available as Open
style, or in NEMA 1, NEMA 7 & 9 or
NEMA 7 & 9 / 3 & 4 enclosures.

Standard Features include:
▪ ON/OFF rotary handle with lockout
and visible trip indication
▪ Adjustment dial for setting to motor
FLA (Starters only)
▪ Low Voltage Protection (LVP) Option
▪ Short Circuit trip at 13 times the
maximum setting of the FLA dial
or rated current
▪ Ambient compensated up to 140°F
▪ Phase loss sensitivity
▪ Test trip function
▪ LVP Option Meets OSHA
Requirements
▪ UL Listed
▪ CSA Certified

NEMA 7 & 9
Div 1 & Div 2
Class I Group C & D
Class II Group E, F & G

NEMA 3 & 4, NEMA 7 & 9
Div 1 & Div 2
Class I Group C & D
Class II Group E, F & G

8/9

Manual Control

Starters and Switches, Class 11 - 3RV
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳

Low Voltage Protection Coil Table

No heaters required.
Field modification kits see page 8/80.
Dimensions see page 8/102.
Wiring Diagrams see page 8/130.
For applications requiring a low voltage protection coil
see table at right.

60 Hz Voltage

Letter

120V
208V
240V
460V

*F
*D
*G
*H

*Add corresponding letter to end of base Class 11
catalog number for low voltage protection coil with
List Price adder.
Note: The LVP option for Open type 3RV is available
from the factory, please order separately from the
field modification kits on page 8/81.

Class 11 Manual Motor Starter

The coil voltage should correspond with the
line voltage.

Manual Starter—Class 11 - 3RV
FLA
Adjustment
Range

0.11-0.16
0.14-0.2
0.18-0.25
0.22-0.32
0.28-0.4
0.35-0.5
0.45-0.63
0.55-0.8
0.7-1
0.9-1.25
1.1-1.6
1.4-2
1.8-2.5
2.2-3.2
2.8-4
3.5-5
4.5-6.3
5.5-8
7-10
9-12.5
11-16
14-20
17-22
20-25

Max HP

Enclosure

Single Phase

3-Phase

Open Type

HP Ratings

HP Ratings

115V

230V

200V

230V

460V

575V

Catalog Number

—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—

—
—
—
—
—
—
—

1

1

1

1

3

3

1
1 1⁄2
2
3
3
5
5
7 1⁄2
7 1⁄2

1
1
1 1⁄2
2
3
3
5
7 1⁄2
7 1⁄2
7 1⁄2

1
1 1⁄2
1 1⁄2
2
3
5
5
7 1⁄2
7 1⁄2
10
15
15
15

1
1 1⁄2
1 1⁄2
2
3
3
5
5
10
10
15
20
20
20

3RV1021-0AA10 
3RV1021-0BA10 
3RV1021-0CA10 
3RV1021-0DA10 
3RV1021-0EA10 
3RV1021-0FA10 
3RV1021-0GA10 
3RV1021-0HA10 
3RV1021-0JA10 
3RV1021-0KA10 
3RV1021-1AA10 
3RV1021-1BA10 
3RV1021-1CA10 
3RV1021-1DA10 
3RV1021-1EA10 
3RV1021-1FA10 
3RV1021-1GA10 
3RV1021-1HA10 
3RV1021-1JA10 
3RV1021-1KA10 
3RV1021-4AA10 
3RV1021-4BA10 
3RV1021-4CA10 
3RV1021-4DA10 

1

⁄10
1
⁄8
1
⁄6
1
⁄4
1
⁄3
1
⁄2
1
⁄2
1
1 1⁄2
2
2

1

⁄10
⁄8
1
⁄6
1
⁄4
1
⁄3
1
⁄2
3
⁄4
1

1
1 1⁄2
2
3
3
3
5

⁄2
⁄4
3
⁄4

⁄2
⁄4

⁄2
3
⁄4
3
⁄4

1

⁄2
⁄2
3
⁄4

NEMA 1

NEMA 7 & 9

NEMA 3 & 4, NEMA 7 & 9 

General Purpose

Class I Groups C & D
Class II Groups E, F & G

Watertight (Outdoor use)
Class I Groups C & D
Class II Groups E, F & G

List Price $ Catalog Number List Price $. Catalog Number List Price $

Catalog Number List Price $

11AD3B
11BD3B
11CD3B
11DD3B
11ED3B
11FD3B
11GD3B
11HD3B
11JD3B
11KD3B
11LD3B
11MD3B
11ND3B
11PD3B
11QD3B
11RD3B
11SD3B
11TD3B
11UD3B
11VD3B
11WD3B
11XD3B
11YD3B
11ZD3B

11AD3H
11BD3H
11CD3H
11DD3H
11ED3H
11FD3H
11GD3H
11HD3H
11JD3H
11KD3H
11LD3H
11MD3H
11ND3H
11PD3H
11QD3H
11RD3H
11SD3H
11TD3H
11UD3H
11VD3H
11WD3H
11XD3H
11YD3H
11ZD3H

11AD3W
11BD3W
11CD3W
11DD3W
11ED3W
11FD3W
11GD3W
11HD3W
11JD3W
11KD3W
11LD3W
11MD3W
11ND3W
11PD3W
11QD3W
11RD3W
11SD3W
11TD3W
11UD3W
11VD3W
11WD3W
11XD3W
11YD3W
11ZD3W

NEMA 1

NEMA 7 & 9

NEMA 3 & 4, NEMA 7 & 9

General Purpose

Class I Groups C & D
Class II Groups E, F & G

Watertight
Class I Groups C & D
Class II Groups E, F & G

Manual Switch—Class 11 - 3RV
Rated
Current

1
5
10
20
25

Max HP

Enclosure

Single Phase

3-Phase

Open Type

HP Ratings

HP Ratings

115V

230V

200V

230V

—

—

1 
6

1 
2

2

1 1⁄2
3
5

—
1
3
5
7 1⁄2

—
1
3
7 1⁄2
7 1⁄2 

⁄
1 
⁄2
1 1⁄2

 Instantaneous

⁄

460V

575V

Catalog Number

1 
2

1 
2

3
7 1⁄2
15
15

3
10
20
20

3RV1321-0JC10 
3RV1321-1FC10 
3RV1321-1JC10 
3RV1321-4BC10 
3RV1321-4DC10 

⁄

Magnetic Trip will occur at 13 times
the maximum FLA dial setting or rated switch current.
 Product Category: IEC

8/10

⁄

List Price $. Catalog Number List Price $ Catalog Number List Price $
111D3B
112D3B
113D3B
114D3B
115D3B

 Shaded

Ratings apply for Manual Motor Controllers
Only! These Ratings do not apply as UL Listed Manual
Combination Starters.

Product Category: NEMA

111D3H
112D3H
113D3H
114D3H
115D3H

Catalog Number List Price $
111D3W
112D3W
113D3W
114D3W
115D3W

 Add

1 to the end of the catalog number for 1/2 inch drain
hole with plug and list price adder. Drain fitting not supplied, order separately XDB-2.

Siemens Industry, Inc.
Industrial Controls Catalog

Heavy Duty Control

Catalog Numbering System
General

ESP 200®
Current Range
Three Phase

A
B
C
D
E
Model
F
G
U — ESP200 size 0–4
H
& size 7 & 8
J
P — Thermal size 0–31⁄2,
K
Solid state size 5 & 6
L
M
N

Class

17 — Combination Starter

Size

(Non Fusible, Fusible)

B
C
D
E
F
G
H
I
J
L
M
N
P

18 — Combination Starter
(Circuit Breaker)
25 — Reversing
Combination Starter
(Non Fusible, Fusible)
26 — Reversing
Combination Starter
(Circuit Breaker)

—
—
—
—
—
—
—
—
—
—
—
—
—

00
0
1
13⁄4
2
21⁄2
3
31⁄2
4
5
6
7
8

—
—
—
—
—
—
—
—
—
—
—
—
—

0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200
100–300 w/ CT’s
133–400 w/ CT’s
200–600 w/ CT’s
250–750 w/ CT’s
400–1200 w/ CT’s

Breaker HP Code
Horsepower Rating
200, 230, 460, 575

A —
B —
C —
D —
E —
F —
G —
H —
J —
K —
L —
M —
N —
P —
R —

Enclosure Size

92 — Standard Width
82 — Extra Wide
Enclosure Type

B
F
H
N
W

—
—
—
—
—

NEMA
NEMA
NEMA
NEMA
NEMA

Pilot Control Circuit

14 — Across the Line NEMA

2 — suitable for

Motor Starter
22 — Reversing NEMA Motor
Starter
40 — Across the Line NEMA
Magnetic Contactor
43 — Reversing NEMA Magnetic
Contactor

Class

Three Phase

00
0
1
13⁄4
2
21⁄2
3
31⁄2
4
5
6
7
8

Size

C —
Combination D —
E —
Reduced
F —
Voltage
G—
Starter
37 — Combination H —
I —
Reduced
J —
Voltage
L —
Starter
M—
N—
P —
36 — Non

 Single

3-wire control
(NO aux.
contact incl.)

ESP 200®
Current Range

Size
—
—
—
—
—
—
—
—
—
—
—
—
—

Model

U — ESP200 size 00–4,
Size 7 & 8

P — Thermal size 00–4,
Solid state sizes 5 & 6

Model

U — ESP200
0
size 0–4
1
& size 7 & 8
13⁄4
P — Thermal
2
1
size 0–31⁄2
2 ⁄2
Solid state
3
size 5 & 6
31⁄2
4
5
6
7
8

phase ESP200 available on Class 14 Starters
only.
used on Class 17, 25 or with ESP200 versions.

⁄2, 1⁄2,1, 1
1, 1, 3, 3
3, 3, 5, 5
3, 3, 71⁄2, 71⁄2
71⁄2, 71⁄2, 10, 10
—, —, 15, 15
10, 10, —, —
71⁄2, 10, 20, 20
10, 15, 25, 25
—, —, 30, 30
15, 20, —, —
—, —, 30, 30
25, 30, 50, 50
30, 40, 75, 75
40, 50, 100, 100

1
4X Fiberglass
7/9/3/4, Bolted (Class 18 & 26 only)
12 (Field convertible to 3/3R/4)
4/4X 304 Stainless Steel

Class

B
C
D
E
F
G
H
I
J
L
M
N
P

1

A
B
C
D
E
F
G
H
J
K
L
M
N

Coil

A — 110–120V/220–240V@60Hz
110V/190–220V@50Hz

C — 220–240V/440–480V@60Hz
190–220V/380–440V@50Hz

D — 200–208V@60Hz
E — 550–600V@60Hz

—
—
—
—
—
—
—
—
—
—
—
—
—

0.25–1
550V@50Hz
0.75–3.4 Enclosure Size
F — 120V@60Hz
3–12
110V@50Hz
1 — 2 power poles,1-phase
5.5–22
G — 220–240V@60Hz
3 — 3 power poles, 3-phase
10–40
190–220V@50Hz
8 — 3 power poles, 3-phase,
13–52
H — 440–480V@60Hz
extra wide enclosure
25–100
380–440V@50Hz
50–200
J — 24V@60Hz
100–300 w/ CT’s
24V@50Hz
133–400 w/ CT’s
L — 277V@60Hz
200–600 w/ CT’s
240V@50Hz
250–750 w/ CT’s
Enclosure Type
400–1200 w/ CT’s
A — Open
Single Phase
B — NEMA 1
F — NEMA 4X Fiberglass
A — 0.25–1
H — NEMA 7/9/3/4, Bolted
B — 0.75–3.4
(Class 18 & 26 only)
C — 3–12
0 — NEMA 12 (Field convertible to 3/3R/4)
D — 5.5–22
W — NEMA 4/4X 304 Stainless Steel

ESP 200®
Current Range Type

T — Auto XFMR
P — Part Wind.
0 — Wye Delta
Open Trans.

C — Wye Delta
Closed Trans.

 Not available on sizes
 For Class 37 only.

5–8.

Line Volts

Enclosure Type

2
3
4
5
6

A — Open
B — NEMA 1
W — NEMA 4/4X

—
—
—
—
—

230
380
460
575
200/208

Coil Disconnect Type

D
E
F
Stainless Steel G
0 — NEMA 12
H
L

D — Non Fused Disc.
F — Fusible Disc.
P — MCP

 Position used for ESP200 only.
 Not available on sizes 7 and 8.

 Not

Siemens Industry, Inc.
Industrial Controls Catalog

8/11

Heavy Duty Starters

Features and Benefits
General

NEMA starters are ideal for
applications requiring dependability
and durability. Typical applications
include use with machine tools, air
conditioning equipment, material
handling equipment, compressors,
hoists and various production and
industrial equipment as well as in
demanding automotive applications.
Starters are available as an open type
or in NEMA 1, 12/3/3R, 4 (painted), 4/4X
(stainless), 4X (fiberglass), and 7 & 9
enclosures.
Solid State Starter Class 14

Standard Features
Size 00–4 magnetic starters include the
following standard features:

▪ Rugged Industrial Design
▪ Half Sizes for Cost and Space Savings
▪ Dual Voltage, Dual Frequency Coils
▪ Solid State or Ambient Compensated
Bimetal Overload Protection
▪ Wide Range of Accessories
▪ Easy Coil Access
▪ Overload Test Feature
▪ Straight Thru Wiring
▪ Gravity Dropout
▪ Large Silver Cadmium Contacts
▪ UL listed file #E14900 (class 14, 22,
30, 40 & 43)
▪ CSA certified file #LR 6535 (class 14,
22, 30, 40 & 43)

Application
Heavy Duty starters are designed for
across the line starting of single phase
and polyphase motors.
These controls are available in NEMA
Sizes 00 through 8. In addition to the
usual NEMA Starter Sizes, Siemens
offers three exclusive Half Sizes; 13⁄4,
21⁄2 and 31⁄2. These integral sizes offer
the same rugged, industrial
construction as our NEMA Sizes and
ensure efficient operating performance.
Half Sizes provide a real cost savings
by cutting down on over capacity when
NEMA Sizes exceed the motor ratings.
All Siemens Heavy Duty controls,
including our popular Half Sizes comply
with applicable NEMA and UL tests.
All starters are supplied with a NO
holding interlock that in conjunction
with an appropriate pilot device will
provide low voltage protection or
release.

8/12

are available to meet particular
application requirements

▪ Normally opened or normally closed
auxiliary power pole kits are available
for Sizes 00 through 13⁄4
▪ Transformers can be ordered as either
factory or field modifications.
In some cases these may require a
larger enclosure
▪ A full line of replacement parts are
available including contact kits, coils,
and overload relays

Gravity Dropout
For added reliability, the gravity dropout
of the armature and contacts is assisted
by stainless steel springs which help
provide quick, precise opening of the
contacts.

Part No
49D70084

45 Degree, Wedge Action Contacts
The 45 degree, wedge action contacts
reduce tracking and provide faster arc
quenching. The resulting self-cleaning
and reduced contact bounce mean
cooler operation and longer life for the
large silver cadmium oxide contacts.
Terminal Design
Control terminals are self-rising
pressure type.
Molded Coil
Magnetic coils are carefully wound and
then sealed in epoxy. Encapsulation
helps seal out moisture, promotes
heat transfer and resists electrical,
mechanical and thermal stresses.
Dual Voltage/Frequency Coil
Starters are available with dual voltage,
dual frequency coils. They are designed
to operate on either 50 or 60 Hertz.

Molded Stationary Contact Block
Thermoset materials resist arc tracking
and the stresses of heat and severe
impact.
Field Modification Kits
All starters can be modified in the field
with a complete range of accessories.
These include pushbuttons, selector
switches, pilot lights, auxiliary contacts
and surge suppressors.
Auxiliary Equipment
▪ NEMA starters are available with
built-in START-STOP push buttons
for 3-wire control or a
HAND-OFF-AUTO selector
switch for 2-wire control
▪ Field modifications such as auxiliary
contacts, pilot lights, push buttons,
selector switches, and fuse blocks

Siemens Sizes 00–13⁄4 have as
standard, universal mounting which
fits the following:
Cutler Hammer—Citation Series
—Freedom Series
GE

—300 Line

Square D

—Type S

The Starter with its existing
backplate mounts onto the piggyback
mounting plate and is secured in
place with three mounting screws.
The piggyback mounting plate fits
the following:
Allen-Bradley

—Bulletin 509
—Bulletin 709

Westinghouse —Series A200

Size 5 & 6 Starters
Additional Features
▪ Solid State Overload (3RB type)
Standard
▪ Latest technology in arc quenching to
extend contactor life
▪ Wide variety of enclosures in all
starter configurations
Size 7 & 8 Starters
Additional Features
▪ New Compact Design
▪ Can be mounted in any position
▪ Same coil voltage is AC or DC
Siemens Industry, Inc.
Industrial Controls Catalog

Heavy Duty Starters

Features and Benefits
General

Half Size Starters
Half-Size starters feature all the
rugged performance characteristics of
our NEMA rated starter sizes, but are
fractionally sized to more closely match
your exact motor rating. As a result,
significant economic savings are made
possible without sacrificing the reliability
you expect from a heavy duty starter.

ESP200™ Solid State Starter

ESP200™ starters combine the rugged
NEMA contactors with a state of the
art solid state overload that provides
phase loss, phase unbalance ground
fault protection. It offers the user
greater motor protection and extended
life in heavy duty applications. The
ESP200™ ultimately results in a cost
savings to the user.

ESP200™ Solid State Overload Relays
Standard features provide Improved
Starter Performance:
▪ True phase loss protection; trips
within 3 seconds
▪ Phase unbalanced prevents motor
running inefficiently
▪ Ground fault trip when selected
▪ Selectable trip class 5, 10, 20 or 30
▪ Reset trip can be selected
Auto/Manual restart
▪ Easy to select and use, Dip Switch
selectable
▪ Overload is self powered, no need for
external power source

These additional starter sizes have the
reserve capacity to handle occasional
plugging and jogging applications
without derating. Superior operating
performance in heavy duty applications
is assured by the large current carrying
parts, not by derating the device.
Exclusive “half-sizes” save potentially
hundreds, even thousands of dollars
per project.
Using the table below, simply match
the specific size starter to the
horsepower rating of your motor.
Every half-size starter saves you
money—up to 31%.

DIP Switch Settings
Adjust DIP switch settings to the Trip
Class desired 5, 10, 20, or 30.
▪
▪
▪
▪

Set Phase Unbalance ON or OFF
Set Phase Loss ON or OFF
Set Reset to Manual or Automatic
Set Ground Fault ON or OFF

All “half-sizes” comply to applicable
NEMA and UL standards.
ESP200® FLA Adjustment Dial—Set the
adjustment dial on the overload to the
FLA of the motor.
Figure 1

Typical Solid-State Overload
Adjustment Dial Markings
Each overload is precisely calibrated
and labels are laser printed.

Savings for Siemens “Half-Size” Starters in NEMA 1 Enclosures, FVNR
Motor Size
230V

7 ⁄

460V

Starter
Size

Half
Size

List Price $

“Half-Size”
Savings Over
Next Full Size

10

1

—

—

10

15

—

13⁄4

31%

15

25

2

—

—

20

30

—

2⁄

20%

30

50

3

—

—

12

12

40

75

—

31⁄2

13%

50

100

4

—

—

Siemens Industry, Inc.
Industrial Controls Catalog

Product Category: NEMA

Standard Auxiliary Contacts
Type

All FVNR
Starters &
Contactors

Size (3rd Character)

Configuration

B Thru E

1N.O.

Internal / External
Internal

F Thru J

1N.O.

External

L Thru M

2N.O., 2N.C.

External

N Thru P

1N.O., 1N.C.

External

8/13

Heavy Duty Motor Starters

Solid State Overload with Auto/Manual Reset, Class 14
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/103 open and 8/116 enclosed.
Wiring Diagrams see page 8/131.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure

Open Type

Overload

200
Volts
1
⁄6
1
⁄2
11⁄2
1
⁄6
1
⁄2
2
3
1
⁄6
1
⁄2
2
3
71⁄2
10
10
15
25
30
40
75
150
—
—

230
Volts
1
⁄6
3
⁄4
11⁄2
1
⁄6
3
⁄4
2
3
1
⁄6
3
⁄4
2
3
71⁄2
10
15
20
30
40
50
100
200
300
450

460
Volts
1
⁄3
11⁄2
2
1
⁄3
11⁄2
5
—
1
⁄3
11⁄2
5
10
—
15
25
30
50
75
100
200
400
600
900

575
Volts
1
⁄2
2
—
1
⁄2
2
5
—
1
⁄2
2
5
10
—
15
25
30
50
75
100
200
400
600
900

NEMA Half
Size Size
00
—
00
—
00
—
0
—
0
—
0
—
0
—
1
—
1
—
1
—
1
—
1
—
—
13⁄4
2
—
—
21⁄2
3
—
—
31⁄2
4
—
5
—
6
—
7
—
8
—

Amp
Range
0.25–1
0.75–3.4
3–12
0.25–1
0.75–3.4
3–12
5.5–22
0.25–1
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
160–630
400–1220
400–1220

Frame
Size
A
A
A1
A
A
A1
A1
A
A
A1
A1
A1
A1
B
B
B
B
B
—
—
A1+CT
A1+CT

NEMA 4/4X Stainless NEMA 4X
Watertight, Dust-tight,
Fiberglass

NEMA 1

Standard Auxiliary
Contacts

General Purpose

Corrosion Resistant
304 Stainless Steel
316 Stainless Steel
Optional)	

Watertight, Dust-tight
Corrosion Resistant

NEMA 7 & 9
NEMA 3 & 4

NEMA 12
NEMA 3/3R

Div. 1 and Div. 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

Industrial Use
Weatherproof
(Field Convertible to 3/3R)

Catalog
List
Catalog
List
Catalog
List
Catalog
List
Catalog
List
Number
Price $ Number
Price $ Number
Price $ Number
Price $ Number
Price $
14BUA32A*
14BUA32B*
Use Size 0
Use Size 0
Use Size 0
—
—
—
14BUB32A*
14BUB32B*
Use Size 0
Use Size 0
Use Size 0
—
—
—
14BUC32A*
14BUC32B*
Use Size 0
Use Size 0
Use Size 0
—
—
—
14CUA32A*
14CUA32B*
14CUA32W*
14CUA32F*
14CUA32H*
14CUB32A*
14CUB32B*
14CUB32W*
14CUB32F*
14CUB32H*
14CUC32A*
14CUC32B*
14CUC32W*
14CUC32F*
14CUC32H*
14CUD32A*
14CUD32B*
14CUD32W*
14CUD32F*
14CUD32H*
14DUA32A*
14DUA32B*
14DUA32W*
14DUA32F*
14DUA32H*
14DUB32A*
14DUB32B*
14DUB32W*
14DUB32F*
14DUB32H*
14DUC32A*
14DUC32B*
14DUC32W*
14DUC32F*
14DUC32H*
14DUD32A*
14DUD32B*
14DUD32W*
14DUD32F*
14DUD32H*
14DUE32A*
14DUE32B*
14DUE32W*
14DUE32F*
14DUE32H*
14EUE32A*
14EUE32B*
14EUE32W*
14EUE32F*
14EUE32H*
14FUF32A*
14FUF32B*
14FUF32W*
14FUF32F*
14FUF32H*
14GUG32A*
14GUG32B*
14GUG32W*
14GUG32F*
14GUG32H*
14HUG32A*
14HUG32B*
14HUG32W*
14HUG32F*
14HUG32H*
14IUH32A*
14IUH32B*
14IUH32W*
14IUH32F*
14IUH32H*
14JUH32A*
14JUH32B*
14JUH32W*
14JUH32F*
14JUH32H*
14LPU32A*
14LPU32B*
14LPU32E*
14LPU32H*
—
—
14MPX32A*
14MPX32B*
14MPX32E*
—
—
—
—
14NUN32A*
14NUN32B*
14NUN32E*
—
—
—
—
14PUN32A*
14PUN32B*
14PUN32E*
—
—
—
—

Catalog
List
Number
Price $
Use Size 0
—
Use Size 0
—
Use Size 0
—
14CUA320*
14CUB320*
14CUC320*
14CUD320*
14DUA320*
14DUB320*
14DUC320*
14DUD320*
14DUE320*
14EUE320*
14FUF320*
14GUG320*
14HUG320*
14IUH320*
14JUH320*
14LPU320*
14MPX320*
14NUN320*
14PUN320*

Open Type & Standard Width Enclosure, Single Phase, 2-Pole
Max Hp

Enclosure

Open Type

Overload

Standard Auxiliary
Contacts

115
Volts
1
⁄8
1
⁄4
1
1
⁄8
1
⁄4
1

208/
230
Volts
1
⁄4
1
⁄2
2
1
⁄4
1
⁄2
2

NEMA
Size
0
0
0
1
1
1

Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22

Frame
Size
A
A1
A1
A
A1
A1

Catalog
Number
14CUB12A*
14CUC12A*
14CUD12A*
14DUB12A*
14DUC12A*
14DUD12A*

NEMA 4/4X Stainless NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight,
Watertight, Dust-tight
Corrosion Resistant
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

List
Catalog
Price $ Number
14CUB12B*
14CUC12B*
14CUD12B*
14DUB12B*
14DUC12B*
14DUD12B*

Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
 Dual voltage coils not available in size 5–8 starters.
 For conduit hubs and conversion instructions, see
page 8/88.

8/14

NEMA 1

List
Catalog
Price $ Number
14CUB12W*
14CUC12W*
14CUD12W*
14DUB12W*
14DUC12W*
14DUD12W*

List
Catalog
Price $ Number
14CUB12F*
14CUC12F*
14CUD12F*
14DUB12F*
14DUC12F*
14DUD12F*

 Coils

D, F, or G will be wired for incoming voltage. J coil
will be wired for separate source. Coils E, H, and L do
not apply to single phase starters.
 Enclosure is NEMA Type 4 (painted steel).
 F coil 100-250V AC 50/60Hz, or DC,
H coil 150-500V AC 50/60Hz, or DC
 Only available F coil100-250V AC 50/60Hz, or DC

Product Category: NEMA

NEMA 7 & 9
NEMA 3 & 4

NEMA 12
NEMA 3/3R

Div. 1 and Div. 2 Class I
Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Catalog
Price $ Number
14CUB12H*
14CUC12H*
14CUD12H*
14DUB12H*
14DUC12H*
14DUD12H*

List
Catalog
Price $ Number
14CUB120*
14CUC120*
14CUD120*
14DUB120*
14DUC120*
14DUD120*

List
Price $

 Standard

Auxiliary Contacts, Same as Contactors,
refer to page 8/13.
Steel option see page 8/98.
with the ESP200 OLR will not be available until approximately December 2009. Continue to
order enclosed starters with the ESP100 OLR until then.

	 For 316 Stainless

 Enclosed starters

Siemens Industry, Inc.
Industrial Controls Catalog

Heavy Duty Motor Starters

Solid State Overload with Auto/Manual Reset, Class 14
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/116.
Wiring Diagrams see page 8/131.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

NEMA 1

Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp

200
Volts

Enclosure

Overload

230
Volts

460
Volts

NEMA 1

NEMA 4/4X Stainless

General Purpose

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

575
Volts

NEMA
Size

Half Amp
Size Range

Frame
Size

Catalog
Number

List
Price $

Catalog
Number

List
Price $

NEMA 7 & 9
NEMA 3 & 4

NEMA 12
NEMA 3/3R

Div. 1 and Div. 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

Industrial Use
Weatherproof
(Field Convertible to 3/3R)

Catalog
Number

Catalog
Number

List
Price $

List
Price $

⁄6

1

⁄6

1

⁄3

1

⁄2

00

—

0.25–1

A

14BUA82B*

Use Size 0

—

Use Size 0

—

Use Size 0

—

1

⁄2

3

⁄4

11⁄2

2

00

—

0.75–3.4

A

14BUB82B*

Use Size 0

—

Use Size 0

—

Use Size 0

—

11⁄2

11⁄2

2

—

00

—

3–12

A1

14BUC82B*

Use Size 0

—

Use Size 0

—

Use Size 0

—

⁄6

1

⁄3

1

⁄2

0

—

0.25–1

A

14CUA82B*

14CUA82W*

14CUA82H*

14CUA820*

1

⁄6

1

1

⁄2

3

⁄4

11⁄2

2

0

—

0.75–3.4

A

14CUB82B*

14CUB82W*

14CUB82H*

14CUB820*

2

2

5

5

0

—

3–12

A1

14CUC82B*

14CUC82W*

14CUC82H*

14CUC820*

3

3

—

—

0

—

5.5–22

A1

14CUD82B*

14CUD82W*

14CUD82H*

14CUD820*

⁄6

1

1

⁄2

1

⁄6

1

⁄3

1

⁄2

1

—

0.25–1

A

14DUA82B*

14DUA82W*

14DUA82H*

14DUA820*

3

⁄4

11⁄2

2

1

—

0.75–3.4

A

14DUB82B*

14DUB82W*

14DUB82H*

14DUB820*

2

2

5

5

1

—

3–12

A1

14DUC82B*

14DUC82W*

14DUC82H*

14DUC820*

3

3

10

10

1

—

5.5–22

A1

14DUD82B*

14DUD82W*

14DUD82H*

14DUD820*

71⁄2

71⁄2

—

—

1

—

10–40

A1

14DUE82B*

14DUE82W*

14DUE82H*

14DUE820*

10

10

15

15

—

13⁄4

10–40

A1

14EUE82B*

14EUE82W*

14EUE82H*

14EUE820*

10

15

25

25

2

—

13–52

B

14FUF82B*

14FUF82W*

14FUF82H*

14FUF820*

15

20

30

30

—

21⁄2

25–100

B

14GUG82B*

14GUG82W*

14GUG82H*

14GUG820*

25

30

50

50

3

—

25–100

B

14HUG82B*

14HUG82W*

14HUG82H*

14HUG820*

30

40

75

75

—

31⁄2

50–200

B

14IUH82B*

14IUH82W*

14IUH82H*

14IUH820*

1

Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).

 For

conduit hubs and conversion instructions, see
page 8/88.

 For

Siemens Industry, Inc.
Industrial Controls Catalog

316 Stainless Steel option see page 8/98.

Product Category: NEMA

 Enclosed

starters with the ESP200 OLR will not be available until approximately December 2009. Continue to
order enclosed starters with the ESP100 OLR until then.

8/15

Heavy Duty Motor Starters

Ambient Compensated Bimetal Overload with Manual and Auto Reset, Class 14
Selection
Ordering Information
䊳

䊳

䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. Single phase starters require 1 heater
element. 3-phase starters require 3 heater elements.
Field Modification Kits page 8/82.
Factory Modifications page 8/95.
Dimensions see page 8/104 open and 8/116 enclosed.
Wiring Diagrams see page 8/131.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure

200
Volts

230
Volts

460
Volts

575
Volts

Contactor
Amp
NEMA Half
Rating Size
Size

1 1⁄2
3
7 1⁄2
10
10
15
25
30
40

1 1⁄2
3
7 1⁄2
10
15
20
30
40
50

2
5
10
15
25
30
50
75
100

2
5
10
15
25
30
50
75
100

9
18
27
40
45
60
90
115
135

00
0
1
—
2
—
3
—
4

—
—
—
13⁄4
—
21⁄2
—
31⁄2
—

Open Type

NEMA 1

Standard Auxiliary
Contacts

General Purpose

NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight
NEMA 3 & 4

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Corrosion Resistant

NEMA 12
NEMA 3/3R

Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

Industrial Use
Weatherproof

Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $

14BP32A*81
14CP32A*81
14DP32A*81
14EP32A*81
14FP32A*81
14GP32A*81
14HP32A*81
14IP32A*81
14JG32A*81

14BP32B*81
14CP32B*81
14DP32B*81
14EP32B*81
14FP32B*81
14GP32B*81
14HP32B*81
14IP32B*81
14JG32B*81

Use Size 0
—
14CP32W*81
14DP32W*81
14EP32W*81
14FP32W*81
14GP32W*81
14HP32W*81
14IP32W*81
14JG32W*81

Use Size 0
14CP32F*81
14DP32F*81
14EP32F*81
14FP32F*81
14GP32F*81
14HP32F*81
14IP32F*81
14JG32F*81

—

Use Size 0 —
14CP32H*81
14DP32H*81
14EP32H*81
14FP32H*81
14GP32H*81
14HP32H*81
14IP32H*81
14JG32H*81

Use Size 0 —
14CP320*81
14DP320*81
14EP320*81
14FP320*81
14GP320*81
14HP320*81
14IP320*81
14JG320*81

Open Type & Standard Width Enclosure, Single Phase, 2-Pole
Max Hp

Enclosure
Open Type

NEMA 1
General Purpose

NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight
Watertight, Dust-tight
NEMA 3 & 4

NEMA 12
NEMA 3/3R

Corrosion Resistant
304 Stainless Steel

Industrial Use
Weatherproof

Corrosion Resistant

Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

115
Volts

208/230
Volts

Contactor
Amp
NEMA
Rating
Size

Half
Size

Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $

1

1
2
3
5
7 1⁄2
10

9
18
27
35
45
60

—
—
—
—
—
21⁄2

14BP12A*81
14CP12A*81
14DP12A*81
14EP12A*81
14FP12A*81
14GP12A*81

⁄3
1
2
3
3
5

00
0
1
1P
2
—

14BP12B*81
14CP12B*81
14DP12B*81
14EP12B*81
14FP12B*81
14GP12B*81

Use Size 0
14CP12W*81
14DP12W*81
14EP12W*81
14FP12W*81
14GP12W*81

—

Use Size 0
14CP12F*81
14DP12F*81
14EP12F*81
14FP12F*81
14GP12F*81

—

Use Size 0
14CP12H*81
14DP12H*81
14EP12H*81
14FP12H*81
14GP12H*81

—

Use Size 0
14CP120*81
14DP120*81
14EP120*81
14FP120*81
14GP120*81

—

Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp

200
Volts
1 1⁄2
3
7 1⁄2
10
10
15
25
30
40

230
Volts
1 1⁄2
3
7 1⁄2
10
15
20
30
40
50

Enclosure

460
Volts
2
5
10
15
25
30
50
75
100

575
Volts
2
5
10
15
25
30
50
75
100

NEMA 4/4X Stainless

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Contactor
Amp
NEMA Half
Rating
Size
Size Catalog No
9
00
— 14BP82B*81
18
0
— 14CP82B*81
27
1
— 14DP82B*81
40
—
1 3⁄4 14EP82B*81
45
2
— 14FP82B*81
60
—
2 1⁄2 14GP82B*81
90
3
— 14HP82B*81
115
—
3 1⁄2 14IP82B*81
135
4
— 14JG82B*81

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All Starter Sizes carry
one maximum Hp rating. For higher Hp single
phase motors, use 3-phase starters, wire and set
per diagram on page 8/131.

8/16

NEMA 1

List Price $

Catalog No
Use Size 0
14CP82W*81
14DP82W*81
14EP82W*81
14FP82W*81
14GP82W*81
14HP82W*81
14IP82W*81
14JG82W*81

 To

List Price $
—

receive a single phase starter in an extra wide
enclosure, order the enclosure kit from pg 8/91 and the
open style starter from pg 8/14 or 8/16 as
separate items.
 For conduit hubs and conversion instructions, see
page 8/88.

Product Category: NEMA

NEMA 7 & 9
NEMA 3 & 4

NEMA 12
NEMA 3/3R

Div 1 and Div 2
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

Industrial Use
Weatherproof

Catalog No
Use Size 0
14CP82H*81
14DP82H*81
14EP82H*81
14FP82H*81
14GP82H*81
14HP82H*81
14IP82H*81
14JG82H*81

Catalog No
Use Size 0
14CP820*81
14DP820*81
14EP820*81
14FP820*81
14GP820*81
14HP820*81
14IP820*81
14JG820*81

List Price $
—

List Price $
—

 Coils

D, F, or G will be wired for incoming voltage.
J coil will be wired for separate source. Coils E, H,
and L do not apply to single phase starters.
 Standard Auxiliary Contacts, Same as Contactors,
refer to page 8/44.
 For 316 Stainless Steel option see page 8/98.

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Heavy Duty Starters

Features and Benefits
General

Combination Starter
Features
Combination starters include
the following features:

▪ Manufactured with Cold Forming
“TOX” Process
▪ Solid State Overloads Standard on
Sizes 5–8
▪ Easy to Install
▪ Wide Range of Enclosure Types
Available
▪ Heavy Duty Quarter Turns
▪ 100kA Short Circuit Current Rating
when Protected with Class R Fuses
to 600V or MCP to 480V
▪ Visible Blade Disconnect
▪ Industrial Type Disconnect Handle
▪ UL listed file #E185287 (class 17, 18,
25, 26 & 32)
▪ CSA certified file #LR 6535 (class 17,
18, 25, 26 & 32)

Application
A combination starter meets National
Electrical Code requirements for:

(stainless), 4X fiberglass and 7 & 9
enclosures. Enclosures protect
personnel from contact with live parts
and depending upon the construction,
protect the control in varying degrees
from physical damage and harmful
atmospheres. All enclosures are
supplied with corrosion resistant
finishes.

Simply start with the enclosure kit
which has the handle preinstalled. You
install the required starter and fusible
disconnect, connect the power wire
and you are finished. Within minutes,
you have the required combination
starter in your hands. No more waiting
on the factory. You need it, your got it!

Heavy Duty Disconnect Switches

▪ Reduce Lead-time - What used to
take days to get now takes minutes
▪ Reduced Inventory - Instead of
stocking scores of various combination starters, simply stock a few
enclosure kits, disconnect kits, circuit
breaker kits and open starters. With
these basic “building blocks” you
virtually have hundreds of products
on-hand
▪ Quality - The same high level of
quality you have been accustomed
to with our products will also be
found in these new enclosure kits
▪ UL Listed - By correctly following
the instructions included with the kits,
the product you build is
UL/CSA Listed
Refer to page 8/93 for more details.
Siemens Type ETI Circuit Breaker
The ETI circuit breaker is a device
designed specifically for application
in motor circuits. The ETI is a magnetic
only protective device designed to
provide protection against short
circuit current.

The disconnect switch that goes the
distance in durability, performance and
reliability has the following advantages:

▪ Visible blades for the highest level
of safety
▪ Double break switching action to
reduce arcing, increase lifetime and
eliminate the “electric hinge”
▪ More rugged positive action switch
▪ Oversized lugs are standard
▪ Line side shield to help guard
personnel from contact with live parts
▪ Higher horsepower rating for
design E high efficiency motors
▪ UL listed for IIsco, Burndy and T&B
crimp type lugs
▪ The 200A switch accepts up to 300
MCM versus 250 MCM wire size
Its rugged construction - with a high
fault withstand rating of 100kA at 600
VAC when fused with class R rated
fuses - meets the most stringent
industry standards set forth by the
automotive, petro-chemical, and pulp
and paper industries. UL recognized and
CSA certified, our disconnect switches
are available either non-fusible or fusible
with class R and class J fuse clips.

1. A means of providing short circuit

What Is In It For You!

The instantaneous-only type ETI circuit
breaker employs adjustable magnetic
trip settings to allow broader application
ranges and a higher degree of motor
short circuit protection.

motor protection with fused or breaker
disconnection of line voltage.
2. A means of safeguarding personnel

from contact with live parts and from
accidental starting of machinery by
disconnecting the motor and the
controller.
3. A motor controller with overload

protection.
Prewired combination starters eliminate
the cost of wiring between separate
disconnect and starter. Factory testing
assures field performance. Combination
starters also provide a more compact
and attractive installation than separate
units.

Enclosure Types
Combination starters are available in
NEMA 1, 12/3/3R/4 (painted), 4/4X
Siemens Industry, Inc.
Industrial Controls Catalog

Enclosure Kits for NEMA
Combination Starters Description
You can assemble a non-stocked combination starter per your unanticipated
needs in minutes. Say, for example,
your customer needs a fusible combination starter that you don’t have in stock.
You need in now, but don’t sweat it.

Heavy Duty Starters
These combination starters use the
same starters described in the heavy
duty starter section of this catalog.

8/17

Combination Heavy Duty Starters

Non-Fusible with Solid State Overload, Class 17
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
For Fusible Styles see page 8/21.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Standard Width Enclosure, 3 Phase, 3-Pole
Max Hp

Enclosure
NEMA 1

Overload

NEMA 4/4X Stainless

General Purpose

200
Volts

230
Volts

460
Volts

575
Volts

NEMA Half
Size
Size

Amp
Range

Disc.
Frame Amp
Size
Range

Catalog
Number

1

⁄6
⁄2
2
3
1
⁄6
1
⁄2
2
3
71⁄2
10
10
15
20
30
40
75
150
—
—

1

⁄6
⁄4
2
3
1
⁄6
3
⁄4
2
3
71⁄2
10
15
20
25
40
50
100
200
300
450

1

3

⁄3
11⁄2
5
—
1
⁄3
11⁄2
5
10
—
15
25
30
50
75
100
200
400
600
900

1

1

⁄2
2
5
—
1
⁄2
2
5
10
—
15
25
30
50
75
100
200
400
600
900

0
0
0
0
1
1
1
1
1
—
2
—
3
—
4
5
6
7

8

0.25–1
0.75–3.4
3–12
5.5–22
0.25–1
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
160–630
400–1220
400–1220

A
A
A1
A1
A
A
A1
A1
A1
A1
B
B
B
B
B
—
—
A1+CT
A1+CT

17CUA92B*
17CUB92B*
17CUC92B*
17CUD92B*
17DUA92B*
17DUB92B*
17DUC92B*
17DUD92B*
17DUE92B*
17EUE92B*
17FUF92B*
17GUG92B*
17HUG92B*
17IUH92B*
17JUH92B*
17LPU92B*
17MPX92B*
17NUN92B*
17PUN92B*

—
—
—
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—

30
30
30
30
30
30
30
30
60
60
60
100
100
200
200
400
800
1200
1600

NEMA 4X Fiberglass

Watertight, Dust-tight,
Watertight, Dust-tight
Corrosion Resistant
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

List
Price $

Catalog
Number

List
Price $

17CUA92W*
17CUB92W*
17CUC92W*
17CUD92W*
17DUA92W*
17DUB92W*
17DUC92W*
17DUD92W*
17DUE92W*
17EUE92W*
17FUF92W*
17GUG92W*
17HUG92W*
17IUH92W*
17JUH92W*
17LPU92E*
17MPX92E*
—
—

Catalog
Number

—
—

Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Price $

17CUA92F*
17CUB92F*
17CUC92F*
17CUD92F*
17DUA92F*
17DUB92F*
17DUC92F*
17DUD92F*
17DUE92F*
17EUE92F*
17FUF92F*
17GUG92F*
17HUG92F*
17IUH92F*
17JUH92F*
—
—
—
—

NEMA 12
NEMA 3/3R

—
—
—
—

Catalog
Number

List
Price $

17CUA92N*
17CUB92N*
17CUC92N*
17CUD92N*
17DUA92N*
17DUB92N*
17DUC92N*
17DUD92N*
17DUE92N*
17EUE92N*
17FUF92N*
17GUG92N*
17HUG92N*
17IUH92N*
17JUH92N*
17LPU92N*
17MPX92N*
17NUN92N*
17PUN92N*

Standard Width Enclosure, Single Phase, (Catalog Numbers are three phase, wire for single phase in the field)
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

115
Volts
⁄8
⁄4
1
1
⁄8
1
⁄4
1

208
230
Volts

NEMA
Size

Half
Size

Amp
Range	

Frame
Size

Disc.
Amp
Range

Catalog
Number

⁄4
⁄2
2
1
⁄4
1
⁄2
2

0
0
0
1
1
1

—
—
—
—
—
—

0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22

A
A1
A1
A
A1
A1

30
30
30
30
30
30

17CUB92B*
17CUC92B*
17CUD92B*
17DUB92B*
17DUC92B*
17DUD92B*

1

1

1

1

List
Price $

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Stee (Optional)

Watertight, Dust-tight
Corrosion Resistant

Catalog
Number

Catalog
Number

List
Price $

17CUB92W*
17CUC92W*
17CUD92W*
17DUB92W*
17DUC92W*
17DUD92W*

17CUB92F*
17CUC92F*
17CUD92F*
17DUB92F*
17DUC92F*
17DUD92F*

Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).

 For


F

 Dual

 For

 Only

voltage coils not available in modified starters or
in starter sizes 5–8.
conduit hubs and conversion instructions, see
page 8/88.
 For 60A disconnect, order fusible cat. no. page 8/21.
 For

8/18

25 HP and 200A disconnect, order fusible cat. no.
page 8/21.
30HP and 200A disconnect, order fusible cat. no.
page 8/21.
 For 600A disconnect, order fusible cat. no. page 8/21.
 Enclosure is NEMA Type 4 (painted steel).
	 For a single phase motor, multiply the motor
nameplate by 0.75 and set the OL dial to the
resulting value.

Product Category: NEMA

List
Price $

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

Catalog
Number

List
Price $

17CUB92N*
17CUC92N*
17CUD92N*
17DUB92N*
17DUC92N*
17DUD92N*

coil 100-250V AC 50/60Hz, or DC,
H coil 150-500V AC 50/60Hz, or DC
available
F coil 100-250V AC 50/60Hz, or DC
 For 316 Stainless Steel option see page 8/98.

 Enclosed starters with the ESP200 OLR will not be available until approximately December 2009. Continue to
order enclosed starters with the ESP100 OLR until then.

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Heavy Duty Starters

Non-Fusible with Solid State Overload, Class 17
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
For Fusible Styles see page 8/22.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Extra Wide Enclosure, 3-Phase, 3-Pole
Hp

200
Volts

Enclosure

Overload

230
Volts

460
Volts

NEMA 1

NEMA 4/4X Stainless

General Purpose

Watertight, Dust-tight, Corrosion
Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

575
Volts

NEMA
Size

Half
Size

Amp
Range

Frame
Size

Disc.
Amp
Range

Catalog
Number

List
Price $

Catalog
Number

List
Price $

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

Catalog
Number

⁄6

1

⁄6

1

⁄3

1

⁄2

0

—

0.25–1

A

30

17CUA82B*

17CUA82W*

17CUA82N*

1

⁄2

3

⁄4

11⁄2

2

0

—

0.75–3.4

A

30

17CUB82B*

17CUB82W*

17CUB82N*

2

2

5

5

0

—

3–12

A1

30

17CUC82B*

17CUC82W*

17CUC82N*

3

3

—

—

0

—

5.5–22

A1

30

17CUD82B*

17CUD82W*

17CUD82N*

⁄6

1

1

⁄2

1

⁄6

1

⁄3

1

⁄2

1

—

0.25–1

A

30

17DUA82B*

17DUA82W*

17DUA82N*

3

⁄4

11⁄2

2

1

—

0.75–3.4

A

30

17DUB82B*

17DUB82W*

17DUB82N*

2

2

5

5

1

—

3–12

A1

30

17DUC82B*

17DUC82W*

17DUC82N*

3

3

10

10

1

—

5.5–22

A1

30

17DUD82B*

17DUD82W*

17DUD82N*

71⁄2

71⁄2

—

—

1

—

10–40

A1

60

17DUE82B*

17DUE82W*

17DUE82N*

10

10

15

15

—

13⁄4

10–40

A1

60

17EUE82B*

17EUE82W*

17EUE82N*

10

15

25

25

2

—

13–52

B

60

17FUF82B*

17FUF82W*

17FUF82N*

15

20

30

30

—

21⁄2

25–100

B

100

17GUG82B*

17GUG82W*

17GUG82N*

20

25

50

50

3

—

25–100

B

100

17HUG82B*

17HUG82W*

17HUG82N*

1

Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
 Dual voltage coils not available in modified starters.
 For conduit hubs and conversion instructions, see

page 8/88.

Siemens Industry, Inc.
Industrial Controls Catalog

 For
 For

60A disconnect, order fusible cat. no. page 8/22.
25 HP and 200A disconnect, order fusible cat. no.
page 8/22.
 For 30HP and 200A disconnect, order fusible cat. no.
page 8/22.

Product Category: NEMA

List
Price $

 For 316 Stainless
 Enclosed starters

Steel option see page 8/98.
with the ESP200 OLR will not be available until approximately December 2009. Continue to
order enclosed starters with the ESP100 OLR until then.

8/19

Combination Heavy Duty Starters

Non-Fusible with Ambient Compensated Bimetal Overload, Class 17
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. (3 required)
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure
NEMA 1
General Purpose

200
Volts
3
71⁄2
10
10
15
25
30
40

230
Volts
3
71⁄2
10
15
20
30
40
50

460
Volts
5
10
15
25
30
50
75
100

575
Volts
5
10
15
25
30
50
75
100

Contactor
Amp
Rating
18
27
40
45
60
90
115
135

Disc
NEMA Half Amp
Size
Size Rating
0
—
30
1
—
30
3
—
1 ⁄4
60
2
—
60
1
—
2 ⁄2
100
3
—
100
1
—
3 ⁄2
200
4
—
200

Catalog Number List Price $
17CP92B*81
17DP92B*81
17EP92B*81
17FP92B*81
17GP92B*81
17HP92B*81
17IP92B*81
17JP92B*81

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (optional) 

Watertight, Dust-tight
Corrosion Resistant

Catalog Number
17CP92W*81
17DP92W*81
17EP92W*81
17FP92W*81
17GP92W*81
17HP92W*81
17IP92W*81
17JP92W*81

Catalog Number
17CP92F*81
17DP92F*81
17EP92F*81
17FP92F*81
17GP92F*81
17HP92F*81
17IP92F*81
17JP92F*81

List Price $

NEMA 12, NEMA 3/3R,
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight

List Price $ Catalog Number List Price $
17CP92N*81
17DP92N*81
17EP92N*81
17FP92N*81
17GP92N*81
17HP92N*81
17IP92N*81
17JP92N*81

Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure
NEMA 1

NEMA 4/4X Stainless

General Purpose

200
Volts
3
71⁄2
10
10
15
25

230
Volts
3
71⁄2
10
15
20
30

460
Volts
5
10
15
25
30
50

Contactor
575
Amp
Volts Rating
5
18
10
27
15
40
25
45
30
60
50
90

Disc
NEMA Half Amp
Size
Size Rating
0
—
30
1
—
30
3
—
1 ⁄4
60
2
—
60
1
—
2 ⁄2
100
3
—
100

NEMA 12, NEMA 3/3R,
NEMA 4 Painted

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (optional) 

Catalog Number
17CP82B*81
17DP82B*81
17EP82B*81
17FP82B*81
17GP82B*81
17HP82B*81

List Price $

Catalog Number
17CP82W*81
17DP82W*81
17EP82W*81
17FP82W*81
17GP82W*81
17HP82W*81

Industrial Use
Weatherproof
Watertight, Dust-tight

List Price $

Catalog Number
17CP82N*81
17DP82N*81
17EP82N*81
17FP82N*81
17GP82N*81
17HP82N*81

List Price $

Standard Width Enclosure, Single Phase, (Catalog Numbers are three phase, wire for single phase in the field)
Max Hp

Enclosure
NEMA 1
General Purpose

115
Volts
1
2
3
3
5

208/ Contactor
Disc
230
Amp
NEMA Half Amp
Volts Rating
Size
Size Rating
2
18
0
—
30
3
27
1
—
30
5
35
1P
—
60
71⁄2
45
2
—
60
10
60
—
21⁄2 100

Catalog Number List Price $
17CP92B*81
17DP92B*81
17EP92B*81
17FP92B*81
17GP92B*81

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.

8/20

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (optional) 

Watertight, Dust-tight
Corrosion Resistant

Catalog Number
17CP92W*81
17DP92W*81
17EP92W*81
17FP92W*81
17GP92W*81

List Price $ Catalog Number
17CP92F*81
17DP92F*81
17EP92F*81
17FP92F*81
17GP92F*81

 Dual voltage coils not available in modified starters.
 For conduit hubs and conversion instructions, see page

8/88.

Product Category: NEMA

 For
 For
 For

NEMA 12, NEMA 3/3R,
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight

List Price $ Catalog Number
17CP92N*81
17DP92N*81
17EP92N*81
17FP92N*81
17GP92N*81

List Price $

60A disc, order fusible cat. no. page 8/23.
200A disc, order fusible cat. no. page 8/23.
316 Stainless Steel option see page 8/98.

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Heavy Duty Starters

Fusible with Solid State Overload, Class 17
Selection
Coil Table

Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure

NEMA 1

Overload

NEMA 4/4X Stainless NEMA 4X Fiberglass

General Purpose

200
Volts
1
⁄6
—
1
⁄2
—
2
—
3
—
1
⁄6
—
1
⁄2
—
2
—
3
—
71⁄2
—
10
10
—
—
—
15
20
—
25
30
—
40
—
75
—
—
—
—
150
—
—
—
—

230
Volts
1
⁄6
—
3
⁄4
—
2
—
3
—
1
⁄6
—
3
⁄4
—
2
—
3
—
71⁄2
—
10
15
—
—
—
20
25
—
30
40
—
50
—
100
100
—
—
—
200
—
—
—
—

460
Volts
—
1
⁄3
—
11⁄2
—
5
—
10
—
1
⁄3
—
11⁄2
—
5
—
10
—
15
—
—
25
—
30
—
—
50
—
—
75
—
100
—
—
—
200
200
—
400
400
600
900

575
Volts
—
1
⁄2
—
2
—
5
—
10
—
1
⁄2
—
2
—
5
—
10
—
15
—
—
25
30
—
—
—
50
—
—
75
—
100
—
—
125
200
—
—
400
400
600
900

NEMA
Size
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
—
—
2
2
—
—
—
3
3
3
—
—
4
4
5
5
5
5
5
6
6
6
7
8

Half
Size
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
21⁄2
—
—
—
31⁄2
31⁄2
—
—
—
—
—
—
—
—
—
—
—
—

Amp
Range
0.25–1
0.25–1
0.75–3.4
0.75–3.4
3–12
3–12
5.5–22
5.5–22
0.25–1
0.25–1
0.75–3.4
0.75–3.4
3–12
3–12
5.5–22
5.5–22
10–40
10–40
10–40
13–52
13–52
13–52
13–52
25–100
25–100
25–100
25–100
50–200
50–200
50–200
50–200
55–250
55–250
55–250
55–250
55–250
160–630
160–630
160–630
400–1220
400–1220

Frame
Size
A
A
A
A
A1
A1
A1
A1
A
A
A
A
A1
A1
A1
A1
A1
A1
A1
B
B
B
B
B
B
B
B
B
B
B
B
—
—
—
—
—
—
—
—
A1+CT
A1+CT

Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
 Dual

voltage coils not available in modified starters or
in starter sizes 5–8.
conduit hubs and conversion instructions, see
page 8/88.

 For

Siemens Industry, Inc.
Industrial Controls Catalog

Disc.
Amp
Range
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
60
60
60
60
60
60
100
100
100
100
200
200
200
200
200
400
600
400
400
600
600
600
800
1200
1600

Fuse Clip
Amp/Volts
30A/250V
30A/600V
30A/250V
30A/600V
30A/250V
30A/600V
30A/250V
30A/600V
30A/250V
30A/600V
30A/250V
30A/600V
30A/250V
30A/600V
30A/250V
30A/600V
60A/250V
60A/600V
60A/250V
60A/250V
60A/600V
60A/600V
100A/600V
100A/250V
100A/250V
100A/600V
200A/250V
200A/250V
200A/600V
200A/250V
200A/600V
400A/250V
600A/250V
200A/600V
400A/600V
600A/600V
600A/250V
600A/600V
800A/600V
1200A/600V
1600A/600V

Watertight, Dust-tight,
Watertight, Dust-tight
Corrosion Resistant
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)	

Catalog
List
Catalog
List
Number
Price $ Number
Price $
17CUA92B*10
17CUA92W*10
17CUA92B*11
17CUA92W*11
17CUB92B*10
17CUB92W*10
17CUB92B*11
17CUB92W*11
17CUC92B*10
17CUC92W*10
17CUC92B*11
17CUC92W*11
17CUD92B*10
17CUD92W*10
17CUD92B*11
17CUD92W*11
17DUA92B*10
17DUA92W*10
17DUA92B*11
17DUA92W*11
17DUB92B*10
17DUB92W*10
17DUB92B*11
17DUB92W*11
17DUC92B*10
17DUC92W*10
17DUC92B*11
17DUC92W*11
17DUD92B*10
17DUD92W*10
17DUD92B*11
17DUD92W*11
17DUE92B*12
17DUE92W*12
17EUE92B*13
17EUE92W*13
17EUE92B*12
17EUE92W*12
17FUF92B*12
17FUF92W*12
17FUF92B*13
17FUF92W*13
17GUF92B*13
17GUF92W*13
17GUF92B*15
17GUF92W*15
17GUG92B*14
17GUG92W*14
17HUG92B*14
17HUG92W*14
17HUG92B*15
17HUG92W*15
17HUG92B*16
17HUG92W*16
17IUH92B*16
17IUH92W*16
17IUH92B*17
17IUH92W*17
17JUH92B*16
17JUH92W*16
17JUH92B*17
17JUH92W*17
17LPU92B*18
17LPU92E*18
17LPU92B*20
17LPU92E*20
17LPU92B*17
17LPU92E*17
17LPU92B*19
17LPU92E*19
17LPU92B*21
17LPU92E*21
17MPX92B*20
17MPX92E*20
17MPX92B*21
17MPX92E*21
17MPX92B*23
17MPX92E*23
17NUN92B*23
—
—
17PUN92B*25
—
—

 Use Class J fuses only.
 Enclosure is NEMA Type 4 (painted
 Single phase wiring page 8/131.
 F coil 100-250V AC 50/60Hz, or DC,

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

Catalog
List
Catalog
List
Number
Price $ Number
Price $
17CUA92F*10
17CUA92N*10
17CUA92F*11
17CUA92N*11
17CUB92F*10
17CUB92N*10
17CUB92F*11
17CUB92N*11
17CUC92F*10
17CUC92N*10
17CUC92F*11
17CUC92N*11
17CUD92F*10
17CUD92N*10
17CUD92F*11
17CUD92N*11
17DUA92F*10
17DUA92N*10
17DUA92F*11
17DUA92N*11
17DUB92F*10
17DUB92N*10
17DUB92F*11
17DUB92N*11
17DUC92F*10
17DUC92N*10
17DUC92F*11
17DUC92N*11
17DUD92F*10
17DUD92N*10
17DUD92F*11
17DUD92N*11
17DUE92F*12
17DUE92N*12
17EUE92F*13
17EUE92N*13
17EUE92F*12
17EUE92N*12
17FUF92F*12
17FUF92N*12
17FUF92F*13
17FUF92N*13
17GUF92F*13
17GUF92N*13
17GUF92F*15
17GUF92N*15
17GUG92F*14
17GUG92N*14
17HUG92F*14
17HUG92N*14
17HUG92F*15
17HUG92N*15
17HUG92F*16
17HUG92N*16
17IUH92F*16
17IUH92N*16
17IUH92F*17
17IUH92N*17
17JUH92F*16
17JUH92N*16
17JUH92F*17
17JUH92N*17
—
—
17LPU92N*18
—
—
17LPU92N*20
—
—
17LPU92N*17
—
—
17LPU92N*19
—
—
17LPU92N*21
—
—
17MPX92N*20
—
—
17MPX92N*21
—
—
17MPX92N*23
—
—
17NUN92N*23
—
—
17PUN92N*25

 Only

steel).

H coil 150-500V AC 50/60Hz, or DC

Product Category: NEMA

available
F coil 100-250V AC 50/60Hz, or DC
Steel option see page 8/98.
with the ESP200 OLR will not be available until approximately December 2009. Continue to
order enclosed starters with the ESP100 OLR until then.

	 For 316 Stainless

 Enclosed starters

8/21

Combination Heavy Duty Starters

Fusible with Solid State Overload, Class 17
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp

200
Volts
⁄6

Enclosure

Overload

NEMA 1

NEMA 4/4X Stainless

General Purpose

Watertight, Dust-tight,
304 Stainless Steel
316 Stainless Steel (Optional)

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

230
Volts

460
Volts

575
Volts

NEMA Half
Size
Size

Amp
Range

Frame
Size

Disc.
Amp
Range

Fuse Clip
Amp/Volts

Catalog
Number

⁄6

—
1
⁄3

—
1
⁄2

0

—

0.25–1

A

30

30A/250V

17CUA82B*10

17CUA82W*10

17CUA82N*10

0

—

0.25–1

A

30

30A/600V

17CUA82B*11

17CUA82W*11

17CUA82N*11

—
11⁄2

—
2

0

—

0.75–3.4

A

30

30A/250V

17CUB82B*10

17CUB82W*10

17CUB82N*10

0

—

0.75–3.4

A

30

30A/600V

17CUB82B*11

17CUB82W*11

17CUB82N*11

—
5

—
5

0

—

3–12

A1

30

30A/250V

17CUC82B*10

17CUC82W*10

17CUC82N*10

0

—

3–12

A1

30

30A/600V

17CUC82B*11

17CUC82W*11

17CUC82N*11

—
10

—
10

0

—

5.5–22

A1

30

30A/250V

17CUD82B*10

17CUD82W*10

17CUD82N*10

—

5.5–22

A1

30

30A/600V

17CUD82B*11

17CUD82W*11

17CUD82N*11

—
1
⁄3

—
1
⁄2

0
1

—

0.25–1

A

30

30A/250V

17DUA82B*10

17DUA82W*10

17DUA82N*10

—

0.25–1

A

30

30A/600V

17DUA82B*11

17DUA82W*11

17DUA82N*11

—
11⁄2

—
2

1
1

—

0.75–3.4

A

30

30A/250V

17DUB82B*10

17DUB82W*10

17DUB82N*10

—

0.75–3.4

A

30

30A/600V

17DUB82B*11

17DUB82W*11

17DUB82N*11

—
5

—
5

1
1

—

3–12

A1

30

30A/250V

17DUC82B*10

17DUC82W*10

17DUC82N*10

1

—

3–12

A1

30

30A/600V

17DUC82B*11

17DUC82W*11

17DUC82N*11

A1

30

30A/250V

17DUD82B*10

17DUD82W*10

17DUD82N*10

1

1

—
1
⁄2

—
3
⁄4

—
2

—
2

—
3

—
3

—
1
⁄6

—
1
⁄6

—
1
⁄2

—
3
⁄4

—
2

—
2

—
3

—
3

—
71⁄2

—
71⁄2

—
10

—
10

10

15

—

—

—

—

—

List
Price $

Catalog
Number

List
Price $

Catalog
Number

—
10

—
10

1

—

5.5–22

1

—

5.5–22

A1

30

30A/600V

17DUD82B*11

17DUD82W*11

17DUD82N*11

—
15

—
15

1

—
13⁄4

10–40

A1

60

60A/250V

17DUE82B*12

17DUE82W*12

17DUE82N*12

10–40

A1

60

60A/600V

17EUE82B*13

17EUE82W*13

17EUE82N*13

—

—

—
2

13⁄4

10–40

A1

60

60A/250V

17EUE82B*12

17EUE82W*12

17EUE82N*12

—

13–52

B

60

60A/250V

17FUF82B*12

17FUF82W*12

17FUF82N*12

2

13–52

B

60

60A/600V

17FUF82B*13

17FUF82W*13

17FUF82N*13

13–52

B

60

60A/600V

17GUF82B*13

17GUF82W*13

17GUF82N*13

—

—
25

—
25
30

—

—

—
30

—
21⁄2

—

—

21⁄2

13–52

B

100

100A/600V

17GUF82B*15

17GUF82W*15

17GUF82N*15

15

20

—

—

21⁄2

25–100

B

100

100A/250V

17GUG82B*14

17GUG82W*14

17GUG82N*14

20

25

—
50

—
3

—

25–100

B

100

100A/250V

17HUG82B*14

17HUG82W*14

17HUG82N*14

3

—

25–100

B

100

100A/600V

17HUG82B*15

17HUG82W*15

17HUG82N*15

—

3

—

25–100

B

200

200A/250V

17HUG82B*16

17HUG82W*16

17HUG82N*16

—

—

—
50

25

30

—

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
 Dual

voltage coils not available in modified starters.

8/22

 For

conduit hubs and conversion instructions, see
page 8/88.
316 Stainless Steel option see page 8/98.

 For

Product Category: NEMA

List
Price $

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Heavy Duty Starters

Fusible with Ambient Compensated Bimetal Overload, Class 17
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. (3 required)
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp

200
Volts
3
—
5
—
7 1⁄2
10
—
10
—
—
—
15
20
—
25
30
—
40
—

Enclosure

230
Volts
3
—
5
—
7 1⁄2
10
—
15
—
—
—
20
25
—
30
40
—
50
—

Contactor
460
575 Amp
Volts Volts Rating
—
—
18
5
5
18
—
—
27
10
10
27
—
—
27
—
—
40
15
15
40
—
—
45
25
25
45
—
30
60
30
—
60
—
—
60
—
—
90
50
50
90
—
—
90
—
—
115
75
75
115
—
—
135
100
100
135

NEMA
Size
0
0
1
1
1
—
—
2
2
—
—
—
3
3
3
—
—
4
4

Half
Size
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
21⁄2
—
—
—
31⁄2
31⁄2
—
—

Disc
Amp
Rating
30
30
30
30
60
60
60
60
60
60
100
100
100
100
200
200
200
200
200

Fuse Clip
Size
Amps/Volts
30A/250V
30A/600V
30A/250V
30A/600V
60A/250V
60A/250V
60A/600V
60A/250V
60A/600V
60A/600V
100A/600V
100A/250V
100A/250V
100A/600V
200A/250V
200A/250V
200A/600V
200A/250V
200A/600V

NEMA 1

NEMA 4/4X Stainless

NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (optional) 

Watertight, Dust-tight
Corrosion Resistant

Catalog
List
Number
Price $
17CP92W*1081
17CP92W*1181
17DP92W*1081
17DP92W*1181
17DP92W*1281
17EP92W*1281
17EP92W*1381
17FP92W*1281
17FP92W*1381
17GP92W*1381
17GP92W*1581
17GP92W*1481
17HP92W*1481
17HP92W*1581
17HP92W*1681
17IP92W*1681
17IP92W*1781
17JP92W*1681
17JP92W*1781

Catalog
List
Number
Price $
17CP92F*1081
17CP92F*1181
17DP92F*1081
17DP92F*1181
17DP92F*1281
17EP92F*1281
17EP92F*1381
17FP92F*1281
17FP92F*1381
17GP92F*1381
17GP92F*1581
17GP92F*1481
17HP92F*1481
17HP92F*1581
17HP92F*1681
17IP92F*1681
17IP92F*1781
17JP92F*1681
17JP92F*1781

Catalog
List
Number
Price $
17CP92B*1081
17CP92B*1181
17DP92B*1081
17DP92B*1181
17DP92B*1281
17EP92B*1281
17EP92B*1381
17FP92B*1281
17FP92B*1381
17GP92B*1381
17GP92B*1581
17GP92B*1481
17HP92B*1481
17HP92B*1581
17HP92B*1681
17IP92B*1681
17IP92B*1781
17JP92B*1681
17JP92B*1781

NEMA 12, NEMA 3/3R,
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight

Catalog
Number
17CP92N*1081
17CP92N*1181
17DP92N*1081
17DP92N*1181
17DP92N*1281
17EP92N*1281
17EP92N*1381
17FP92N*1281
17FP92N*1381
17GP92N*1381
17GP92N*1581
17GP92N*1481
17HP92N*1481
17HP92N*1581
17HP92N*1681
17IP92N*1681
17IP92N*1781
17JP92N*1681
17JP92N*1781

List
Price $

Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp

200
Volts
3
—
5
—
7 1⁄2
10
—
10
—
—
—
15
20
—
25

Enclosure

230
Volts
3
—
5
—
7 1⁄2
10
—
15
—
—
—
20
25
—
30

460
Volts
—
5
—
10
—
—
15
—
25
—
30
—
—
50
—

575
Volts
—
5
—
10
—
—
15
—
25
30
—
—
—
50
—

Contactor
Amp
Rating
18
18
27
27
27
40
40
45
45
60
60
60
90
90
90

NEMA
Size
0
0
1
1
1
—
—
2
2
—
—
—
3
3
3

Half
Size
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
21⁄2
—
—
—

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.

Siemens Industry, Inc.
Industrial Controls Catalog

Disc
Amp
Rating
30
30
30
30
60
60
60
60
60
60
100
100
100
100
200

Fuse Clip
Size
Amps/Volts
30A/250V
30A/600V
30A/250V
30A/600V
60A/250V
60A/250V
60A/600V
60A/250V
60A/600V
60A/600V
100A/600V
100A/250V
100A/250V
100A/600V
200A/250V

NEMA 1

NEMA 4/4X Stainless

General Purpose

Watertight, Dust-tight
Industrial Use Weatherproof
304 Stainless Steel
316 Stainless Steel (optional) 

Industrial Use
Weatherproof
Watertight, Dust-tight

Catalog Number
17CP82W*1081
17CP82W*1181
17DP82W*1081
17DP82W*1181
17DP82W*1281
17EP82W*1281
17EP82W*1381
17FP82W*1281
17FP82W*1381
17GP82W*1381
17GP82W*1581
17GP82W*1481
17HP82W*1481
17HP82W*1581
17HP92W*1681

Catalog Number
17CP82N*1081
17CP82N*1181
17DP82N*1081
17DP82N*1181
17DP82N*1281
17EP82N*1281
17EP82N*1381
17FP82N*1281
17FP82N*1381
17GP82N*1381
17GP82N*1581
17GP82N*1481
17HP82N*1481
17HP82N*1581
17HP92N*1681

Catalog Number
17CP82B*1081
17CP82B*1181
17DP82B*1081
17DP82B*1181
17DP82B*1281
17EP82B*1281
17EP82B*1381
17FP82B*1281
17FP82B*1381
17GP82B*1381
17GP82B*1581
17GP82B*1481
17HP82B*1481
17HP82B*1581
17HP92B*1681

List Price $

 Dual voltage coils not available in modified starters.
 For conduit hubs and conversion instructions, see page

List Price $

NEMA 12, NEMA 3/3R,
NEMA 4 Painted

 Single phase wiring page 8/131.
 For 316 Stainless Steel option see

List Price $

page 8/98.

8/88.

Product Category: NEMA

8/23

Combination Heavy Duty Starters

MCP Type with Solid State Overload, Class 18
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

Motor Circuit
200 230 460 575 NEMA Half Interruter ETI Amp
Volts Volts Volts Volts Size Size Amps
Range

Frame Catalog
Size Number

List
Price $

NEMA 4/4X Stainless NEMA 4X
Watertight, Dust-tight,
Fiberglass

NEMA 7 & 9
NEMA 3 & 4

NEMA 12
NEMA 3/3R

Corrosion Resistant
Watertight, Dust-tight
304 Stainless Steel
Corrosion Resistant
316 Stainless Steel (Optional)

Div. 1 and Div. 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

Industrial Use
Weatherproof
(Field Convertible to 3/3R)

Catalog
Number

List
Price $

Catalog
Number

List
Catalog
Price $ Number

List
Price $

Catalog
Number

1

⁄2

1

⁄2

1

1

0

—

3

0.75–3.4

A

18CUB92B*

18CUB92W*

18CUB92F*

18CUB92H*

18CUB92N*

2

2

5

5

0

—

10

3–12

A1

18CUC92B*

18CUC92W*

18CUC92F*

18CUC92H*

18CUC92N*

3

3

—

25

5.5–22

A1

18CUD92B*

18CUD92W*

18CUD92F*

18CUD92H*

18CUD92N*

⁄2

1

⁄2

—
1

0

1

—
1

1

—

3

0.75–3.4

A

18DUB92B*

18DUB92W*

18DUB92F*

18DUB92H*

18DUB92N*

2

2

5

5

1

—

10

3–12

A1

18DUC92B*

18DUC92W*

18DUC92F*

18DUC92H*

18DUC92N*

3

3

7 1⁄2

10

1

—

25

5.5–22

A1

18DUD92B*

18DUD92W*

18DUD92F*

18DUD92H*

18DUD92N*

7 1⁄2

7 1⁄2

10

1

10–40

A1

18DUE92B*

18DUE92W*

18DUE92F*

18DUE92H*

18DUE92N*

—
15

15

—
13⁄4

30

—
10

—
15

40

10–40

A1

18EUE92B*

18EUE92W*

18EUE92F*

18EUE92H*

18EUE92N*

25

25

50

13–52

B

18FUF92B*

18FUF92W*

18FUF92F*

18FUF92H*

18FUF92N*

15

20

30

30

—
2 1⁄2

100

25–100

B

18GUG92B*

18GUG92W*

18GUG92F*

18GUG92H*

18GUG92N*

25

30

50

50

100

25–100

B

18HUG92B*

18HUG92W*

18HUG92F*

18HUG92H*

18HUG92N*

30

40

75

75

125

50–200

B

18IUH92B*

18IUH92W*

18IUH92F*

18IUH92H*

18IUH92N*

40

50

100

100

—
4

—
3 1⁄2
—

150

50–200

B

18JUH92B*

18JUH92W*

18JUH92F*

18JUH92H*

18JUH92N*

50

75

150

200

5

—

250

55–250

—

18LPT92B*

18LPT92E*

—

—

18LPT92H*

18LPT92N*

75

100

200

5

—

400

55–250

—

18LPU92B*

18LPU92E*

—

—

18LPU92H*

100

125

250

—
300

6

—

400

160–630

—

18MPW92B*

18MPW92E*

—

—

—

—

18MPW92N*

150

200

400

400

6

—

600

160–630

—

18MPX92B*

18MPX92E*

—

—

—

—

18MPX92N*

—

250

500

500

7

—

800

400–1220 A1+CT 18NUV92B*

—

—

—

—

—

—

18NUV92N*

—

300

600

600

7

—

1000

400–1220 A1+CT 18NUY92B*

—

—

—

—

—

—

18NUY92N*

—

400

800

800

8

—

1200

400–1220 A1+CT 18PUW92B*

—

—

—

—

—

—

18PUW92N*

—

450

900

900

8

—

1600

400–1220 A1+CT 18PUZ92B*

—

—

—

—

—

—

18PUZ92N*

—
2
—
3

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).

 For

 Only

 Dual

 Enclosure is NEMA Type 4 (painted
 F coil 100-250V AC 50/60Hz, or DC,

 For 316 Stainless
 Enclosed starters

voltage coils not available in modified starters or
in starter sizes 5–8.

8/24

conduit hubs and conversion instructions, see
page 8/88.
steel).
H coil 150-500V AC 50/60Hz, or DC

Product Category: NEMA

List
Price $

18LPU92N*

available
F coil 100-250V AC 50/60Hz, or DC
Steel option see page 8/98.
with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Heavy Duty Starters

MCP Type with Solid State Overload, Class 18
Selection
Ordering Information

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.

䊳

䊳
䊳
䊳
䊳
䊳

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure
NEMA 1

Overload

NEMA 4/4X Stainless

200
Volts

230
Volts

460
Volts

575
Volts

NEMA
Size

Half
Size

Motor
Circuit
Interruter
ETI Amps

Amp
Range

Frame
Size

Catalog
Number

NEMA 12

Watertight, Dust-tight, Corrosion Resistant NEMA 3/3R
304 Stainless Steel
Industrial Use
316 Stainless Steel (Optional)
Weatherproof
(Field Convertible to 3/3R)

General Purpose

List
Price $

Catalog
Number

List
Price $

Catalog
Number

1

⁄2

1

⁄2

1

1

0

—

3

0.75–3.4

A

18CUB82B*

18CUB82W*

18CUB82N*

2

2

5

5

0

—

10

3–12

A1

18CUC82B*

18CUC82W*

18CUC82N*

3

3

—

—

0

—

25

5.5–22

A1

18CUD82B*

18CUD82W*

18CUD82N*

1

⁄2

1

⁄2

1

1

1

—

3

0.75–3.4

A

18DUB82B*

18DUB82W*

18DUB82N*

2

2

5

5

1

—

10

3–12

A1

18DUC82B*

18DUC82W*

18DUC82N*

3

3

71⁄2

10

1

—

25

5.5–22

A1

18DUD82B*

18DUD82W*

18DUD82N*

71⁄2

71⁄2

10

—

1

—

30

10–40

A1

18DUE82B*

18DUE82W*

18DUE82N*

—

—

15

15

—

13⁄4

40

10–40

A1

18EUE82B*

18EUE82W*

18EUE82N*

10

15

25

25

2

—

50

13–52

B

18FUF82B*

18FUF82W*

18FUF82N*

15

20

30

30

—

21⁄2

100

25–100

B

18GUG82B*

18GUG82W*

18GUG82N*

25

30

50

50

3

—

100

25–100

B

18HUG82B*

18HUG82W*

18HUG82N*

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
 Dual

voltage coils not available in modified starters.

Siemens Industry, Inc.
Industrial Controls Catalog

 For

conduit hubs and conversion instructions, see
page 8/88.
316 Stainless Steel option see page 8/98.

 For

Product Category: NEMA

List
Price $

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

8/25

Combination Heavy Duty Starters

MCP Type with Ambient Compensated Bimetal Overload, Class 18
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. (3 required)
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure

Contactor
200 230 460 575 Amp NEMA Half
Volts Volts Volts Volts Rating Size Size
1
⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
10
10
15
—
25
30
40

1
⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
15
15
20
—
30
40
50

1
3
5
1
3
7 1⁄2
10
15
—
20
25
30
—
30
50
75
100

1
3
5
1
3
7 1⁄2
10
15
—
20
25
30
—
30
50
75
100

18
18
18
27
27
27
27
40
40
45
45
60
60
90
90
115
135

0
0
0
1
1
1
1
—
—
2
2
—
—
3
3
—
4

—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
—
—
31⁄2
—

Motor
Circuit
Interrupter
ETI Amps

3
10
25
3
10
25
30
40
50
40
50
50
100
50
100
125
150

NEMA 1

NEMA 4/4X Stainless NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight

Watertight, Dust-tight

Corrosion Resistant
304 Stainless Steel
316 Stainless Steel

Corrosion Resistant

(optional)

Catalog
Number

List
Catalog
Price $ Number

18CP92BA*81
18CP92BB*81
18CP92BC*81
18DP92BA*81
18DP92BB*81
18DP92BD*81
18DP92BE*81
18EP92BF*81
18EP92BG*81
18FP92BH*81
18FP92BJ*81
18GP92BK*81
18GP92BL*81
18HP92BM*81
18HP92BN*81
18IP92BP*81
18JP92BR*81

List
Catalog
Price $ Number

18CP92WA*81
18CP92WB*81
18CP92WC*81
18DP92WA*81
18DP92WB*81
18DP92WD*81
18DP92WE*81
18EP92WF*81
18EP92WG*81
18FP92WH*81
18FP92WJ*81
18GP92WK*81
18GP92WL*81
18HP92WM*81
18HP92WN*81
18IP92WP*81
18JP92WR*81

NEMA 7 & 9
NEMA 3 & 4

NEMA 12,NEMA 3/3R,
NEMA 4 Painted

Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

Industrial Use
Weatherproof

List
Catalog
Price $ Number

18CP92FA*81
18CP92FB*81
18CP92FC*81
18DP92FA*81
18DP92FB*81
18DP92FD*81
18DP92FE*81
18EP92FF*81
18EP92FG*81
18FP92FH*81
18FP92FJ*81
18GP92FK*81
18GP92FL*81
18HP92FM*81
18HP92FN*81
18IP92FP*81
18JP92FR*81

List
Price $

18CP92HA*81
18CP92HB*81
18CP92HC*81
18DP92HA*81
18DP92HB*81
18DP92HD*81
18DP92HE*81
18EP92HF*81
18EP92HG*81
18FP92HH*81
18FP92HJ*81
18GP92HK*81
18GP92HL*81
18HP92HM*81
18HP92HN*81
18IP92HP*81
18JP92HR*81

Watertight, Dust-tight

Catalog
Number

List
Price $

18CP92NA*81
18CP92NB*81
18CP92NC*81
18DP92NA*81
18DP92NB*81
18DP92ND*81
18DP92NE*81
18EP92NF*81
18EP92NG*81
18FP92NH*81
18FP92NJ*81
18GP92NK*81
18GP92NL*81
18HP92NM*81
18HP92NN*81
18IP92NP*81
18JP92NR*81

Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure
NEMA 1

200
Volts
1

⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
10
10
15
—
25

230
Volts
1

⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
15
15
20
—
30

460
Volts

1
3
5
1
3
7 1⁄2
10
15
—
20
25
30
—
30
50

575
Volts

1
3
5
1
3
7 1⁄2
10
15
—
20
25
30
—
30
50

Contactor
Amp
Rating

NEMA
Size

18
18
18
27
27
27
27
40
40
45
45
60
60
90
90

0
0
0
1
1
1
1
—
—
2
2
—
—
3
3

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.

8/26

Half
Size

Motor Circuit
Interrupter ETI Amps

—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
—
—

3
10
25
3
10
25
30
40
50
40
50
50
100
50
100

Catalog
Number

NEMA 4/4X Stainless

NEMA 12, NEMA 3/3R,

Catalog
Number

Catalog
Number

Watertight, Dust-tight
NEMA 4 Painted
Corrosion Resistant
Industrial Use
304 Stainless Steel
Weatherproof
316 Stainless Steel (optional) Watertight, Dust-tight

General Purpose

List
Price $

18CP82BA*81
18CP82BB*81
18CP82BC*81
18DP82BA*81
18DP82BB*81
18DP82BD*81
18DP82BE*81
18EP82BF*81
18EP82BG*81
18FP82BH*81
18FP82BJ*81
18GP82BK*81
18GP82BL*81
18HP82BM*81
18HP82BN*81

 Dual voltage coils not available in modified starters.
 For conduit hubs and conversion instructions, see

List
Price $

18CP82WA*81
18CP82WB*81
18CP82WC*81
18DP82WA*81
18DP82WB*81
18DP82WD*81
18DP82WE*81
18EP82WF*81
18EP82WG*81
18FP82WH*81
18FP82WJ*81
18GP82WK*81
18GP82WL*81
18HP82WM*81
18HP82WN*81
 For

List
Price $

18CP82NA*81
18CP82NB*81
18CP82NC*81
18DP82NA*81
18DP82NB*81
18DP82ND*81
18DP82NE*81
18EP82NF*81
18EP82NG*81
18FP82NH*81
18FP82NJ*81
18GP82NK*81
18GP82NL*81
18HP82NM*81
18HP82NN*81

316 Stainless Steel option see page 8/98.

page 8/88.

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Reversing Heavy Duty Starters

Solid State Overload, Class 22
Selection

Ordering Information
䊳

䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/105 open and 8/121 enclosed.
Wiring Diagrams see page 8/134.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure
Open Type

Overload

NEMA 1

Standard Auxiliary
Contacts

200 230 460 575 NEMA Half Amp
Volts Volts Volts Volts Size Size Range

Frame Catalog
Size Number

General Purpose

List
Catalog
Price $ Number

NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight,
Watertight, Dust-tight
NEMA 3 & 4

NEMA 12
NEMA 3/3R

Corrosion Resistant
304 Stainless Steel
316 Stainless Steel
(Optional)

Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Catalog
Price $ Number

Corrosion Resistant

List
Catalog
Price $ Number

Div. 1 and Div. 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

List
Catalog
Price $ Number

List
Catalog
Price $ Number

List
Price $

⁄6

1

⁄6

1

⁄3

1

⁄2

00

—

0.25–1

A

22BUA32A*

22BUA32B*

Use Size 0

—

Use Size 0

—

Use Size 0

—

Use Size 0

—

1

⁄2

3

⁄4

11⁄2

2

00

—

0.75–3.4 A

22BUB32A*

22BUB32B*

Use Size 0

—

Use Size 0

—

Use Size 0

—

Use Size 0

—

11⁄2

11⁄2

2

—

00

—

3–12

A1

22BUC32A*

22BUC32B*

Use Size 0

—

Use Size 0

—

Use Size 0

—

Use Size 0

—

⁄6

1

⁄3

1⁄2

0

—

0.25–1

A

22CUA32A*

22CUA32B*

22CUA32W*

22CUA32F*

22CUA32H*

22CUA320*

1

⁄6

1

1

⁄2

3

⁄4

11⁄2

2

0

—

0.75–3.4 A

22CUB32A*

22CUB32B*

22CUB32W*

22CUB32F*

22CUB32H*

22CUB320*

2

2

5

5

0

—

3–12

A1

22CUC32A*

22CUC32B*

22CUC32W*

22CUC32F*

22CUC32H*

22CUC320*

3

3

—

—

0

—

5.5–22

A1

22CUD32A*

22CUD32B*

22CUD32W*

22CUD32F*

22CUD32H*

22CUD320*

⁄6

1

1

⁄2

1

⁄6

1

⁄3

1

⁄2

1

—

0.25–1

A

22DUA32A*

22DUA32B*

22DUA32W*

22DUA32F*

22DUA32H*

22DUA320*

3

⁄4

11⁄2

2

1

—

0.75–3.4 A

22DUB32A*

22DUB32B*

22DUB32W*

22DUB32F*

22DUB32H*

22DUB320*

2

2

5

5

1

—

3–12

A1

22DUC32A*

22DUC32B*

22DUC32W*

22DUC32F*

22DUC32H*

22DUC320*

3

3

10

10

1

—

5.5–22

A1

22DUD32A*

22DUD32B*

22DUD32W*

22DUD32F*

22DUD32H*

22DUD320*

71⁄2

71⁄2

—

—

1

—

10–40

A1

22DUE32A*

22DUE32B*

22DUE32W*

22DUE32F*

22DUE32H*

22DUE320*

10

10

15

15

—

13⁄4

10–40

A1

22EUE32A*

22EUE32B*

22EUE32W*

22EUE32F*

22EUE32H*

22EUE320*

10

15

25

25

2

—

13–52

B

22FUF32A*

22FUF32B*

22FUF32W*

22FUF32F*

22FUF32H*

22FUF320*

15

20

30

30

—

21⁄2

25–100

B

22GUG32A*

22GUG32B*

22GUG32W*

22GUG32F*

22GUG32H*

22GUG320*

25

30

50

50

3

—

25–100

B

22HUG32A*

22HUG32B*

22HUG32W*

22HUG32F*

22HUG32H*

22HUG320*

30

40

75

75

—

31⁄2

50–200

B

22IUH32A*

22IUH32B*

22IUH32W*

22IUH32F*

22IUH32H*

22IUH320*

40

50

100

100

4

—

50–200

B

22JUH32A*

22JUH32B*

22JUH32W*

22JUH32F*

22JUH32H*

75

100

200

200

5

—

55–250

—

22LPU32A*

22LPU32B*

22LPU32E*

—

—

—

—

22LPU320*

150

200

400

400

6

—

160–630 —

22MPX32A*

22MPX32B*

22MPX32E*

—

—

—

—

22MPX320*

—

300

600

600

7

—

400–1220 A1+CT 22NUN32A*

22NUN32B*

—

—

—

—

—

—

22NUN320*

—

450

900

900

8

—

400–1220 A1+CT 22PUN32A*

22PUN32B*

—

—

—

—

—

—

22PUN320*

1

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
 Dual voltage coils not available in size 5–8 starters.
 For conduit hubs and conversion instructions, see
page 8/88.

Siemens Industry, Inc.
Industrial Controls Catalog

 Enclosure is rated
 Only available

only NEMA 4 (painted steel).

F coil 100-250V AC 50/60Hz, or DC
H coil 150-500V AC 50/60Hz, or DC
 Only available
F coil 100-250V AC 50/60Hz, or DC

Product Category: NEMA

22JUH320*

 Auxiliary

contacts
22B-22E 4th pole built-in
22F-22J 2 NO & 2 NC
 Enclosed starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

8/27

Reversing Heavy Duty Starters

Ambient Compensated Bimetal Overload with Manual and Auto Reset, Class 22
Selection
Ordering Information
䊳

䊳

䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. Single phase starters require 1 heater
element. 3-phase starters require 3 heater elements.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/105 open and 8/121 enclosed.
Wiring Diagrams see page 8/133.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure
Open Type

NEMA 1

NEMA 4/4X Stainless NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight, Dust-tight
Corrosion Resistant
Indoor/Outdoor Use

NEMA 7 & 9
NEMA 3 & 4

NEMA 12
NEMA 3/3R

Div 1 and Div 2
Class I Groups C & D

Industrial Use
Weatherproof

Class II Groups E, F & G
Class III

Contactor
200 230 460 575 Amp NEMA Half Catalog
Volts Volts Volts Volts Rating Size Size Number

1 1⁄2
3
7 1⁄2
10
10
15
25
30
40

1 1⁄2
3
7 1⁄2
10
15
20
30
40
50

2
2
5
5
10 10
15 15
25 25
30 30
50 50
75 75
100 100

9
18
27
40
45
60
90
115
135

00
0
1
—
2
—
3
—
4

—
—
—
1 3⁄4
—
2 1⁄2
—
3 1⁄2
—

Bolted Enclosures

List
Catalog
Price $ Number

22BP32A*81
22CP32A*81
22DP32A*81
22EP32A*81
22FP32A*81
22GP32A*81
22HP32A*81
22IP32A*81
22JG32A*81

List
Catalog
Price $ Number

22BP32B*81
22CP32B*81
22DP32B*81
22EP32B*81
22FP32B*81
22GP32B*81
22HP32B*81
22IP32B*81
22JG32B*81

List
Price $

Use Size 0
22CP32W*81
22DP32W*81
22EP32W*81
22FP32W*81
22GP32W*81
22HP32W*81
22IP32W*81
22JG32W*81

—

Catalog
Number

Use Size 0
22CP32F*81
22DP32F*81
22EP32F*81
22FP32F*81
22GP32F*81
22HP32F*81
22IP32F*81
22JG32F*81

List
Catalog
Price $ Number

—

List
Catalog
Price $ Number

Use Size 0
22CP32H*81
22DP32H*81
22EP32H*81
22FP32H*81
22GP32H*81
22HP32H*81
22IP32H*81
22JG32H*81

—

Use Size 0
22CP320*81
22DP320*81
22EP320*81
22FP320*81
22GP320*81
22HP320*81
22IP320*81
22JG320*81

List
Price $

—

Open Type & Standard Width Enclosure, Single Phase, 3-Wire, 2-Pole
Max Hp

Enclosure
Open Type

NEMA 1
General Purpose

NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight
Watertight, Dust-tight
NEMA 3 & 4

NEMA 12
NEMA 3/3R

Corrosion Resistant
304 Stainless Steel

Industrial Use
Weatherproof

Corrosion Resistant

Div 1 and Div 2
Class I Groups C & D

Class II Groups E, F & G
Class III

115
Volts

208/
230
Volts

1

⁄3

1
2
3

1
2
3
5

Contactor
Amp
NEMA Catalog
Rating
Size
Number

9
18
27
35

00
0
1
1P

Bolted Enclosures
Indoor/Outdoor Use

List
Catalog
Price $ Number

22BP12A*81
22CP12A*81
22DP12A*81
22EP12A*81

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All Starter Sizes carry
one maximum Hp rating.

8/28

22BP12B*81
22CP12B*81
22DP12B*81
22EP12B*81

List
Catalog
Price $ Number

Use Size 0
22CP12W*81
22DP12W*81
22EP12W*81

List
Price $

—

 For


Catalog
Number

Use Size 0
22CP12F*81
22DP12F*81
22EP12F*81

conduit hubs and conversion instructions, see
page 8/88.
Coil D, F, or G will be wired for Incoming Voltage.
J coil will be wired for 24V separate source. Coils E,
H, and L do not apply to single phase starters.

Product Category: NEMA

List
Catalog
Price $ Number

—

Use Size 0
22CP12H*81
22DP12H*81
22EP12H*81

List
Catalog
Price $ Number

—

Use Size 0
22CP120*81
22DP120*81
22EP120*81

List
Price $

—

 Auxiliary

contacts
22B-22E 4th pole built-in
22F-22J 2 NO & 2 NC

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Reversing Heavy Duty Starters

Non-Fusible, Class 25
Selection

Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150.
Fuse clips see page 8/96.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/123.
Wiring Diagrams see page 8/135.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Standard Width Enclosure with Solid State Overload, 3-Phase, 3-Pole
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

200 230 460 575 NEMA Half Amp
Volts Volts Volts Volts Size
Size Range

Frame
Size

Disc.
Amp
Range

Catalog
Number

1

⁄6
⁄2
2
3

1

1

3

1

⁄6
⁄2
2
3
71⁄2

1

1

3

List
Price $

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

Catalog
Number

Catalog
Number

List
Price $

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Price $

Catalog
Number

⁄6
⁄4
2
3

1

⁄3
11⁄2
5
—

1

⁄2
2
5
—

0
0
0
0

—
—
—
—

0.25–1
0.75–3.4
3–12
5.5–22

A
A
A1
A1

30
30
30
30

25CUA92B*
25CUB92B*
25CUC92B*
25CUD92B*

25CUA92W*
25CUB92W*
25CUC92W*
25CUD92W*

25CUA92F*
25CUB92F*
25CUC92F*
25CUD92F*

25CUA92N*
25CUB92N*
25CUC92N*
25CUD92N*

⁄6
⁄4
2
3
71⁄2

1

⁄3
11⁄2
5
10
—

1

⁄2
2
5
10
—

1
1
1
1
1

—
—
—
—
—

0.25–1
0.75–3.4
3–12
5.5–22
10–40

A
A
A1
A1
A1

30
30
30
30
60

25DUA92B*
25DUB92B*
25DUC92B*
25DUD92B*
25DUE92B*

25DUA92W*
25DUB92W*
25DUC92W*
25DUD92W*
25DUE92W*

25DUA92F*
25DUB92F*
25DUC92F*
25DUD92F*
25DUE92F*

25DUA92N*
25DUB92N*
25DUC92N*
25DUD92N*
25DUE92N*

10

10

15

15

—

13⁄4

10–40

A1

60

25EUE92B*

25EUE92W*

25EUE92F*

25EUE92N*

10

15

25

25

2

—

13–52

B

60

25FUF92B*

25FUF92W*

25FUF92F*

25FUF92N*

15

20

30

30

—

21⁄2

25–100

B

100

25GUG92B*

25GUG92W*

25GUG92F*

25GUG92N*

20

25

50

50

3

—

25–100

B

100

25HUG92B*

25HUG92W*

25HUG92F*

25HUG92N*

30

40

75

75

—

31⁄2

50–200

B

200

25IUH92B*

25IUH92W*

25IUH92F*

25IUH92N*

40

50

100

100

4

—

50–200

B

200

25JUH92B*

25JUH92W*

25JUH92F*

75

100

200

200

5

—

55–250

—

400

25LPU92B*

25LPU92E*

—

—

25LPU92N*

150

200

400

400

6

—

160–630

—

800

25MPX92B*

25MPX92E*

—

—

25MPX92N*

—

300

600

600

7

—

400–1220

A1+CT

1200

25NUN92B*

—

—

—

—

25NUN92N*

—

450

900

900

8

—

400–1220

A1+CT

1600

25PUN92B*

—

—

—

—

25PUN92N*

List
Price $

25JUH92N*

Standard Width Enclosure with Ambient Compensated Bimetal Overload, 3-Phase, 3-Pole
Max Hp

200
Volts
3
7 1⁄2
10
10
15
25
30
40

230
Volts
3
7 1⁄2
10
15
20
30
40
50

Enclosure

460
Volts
5
10
15
25
30
50
75
100

575
Volts
5
10
15
25
30
50
75
100

Contactor
Amp
NEMA Half
Rating Size
Size
18
0
—
27
1
—
40
—
13⁄4
45
2
—
60
—
21⁄2
90
3
—
115
—
31⁄2
135
4
—

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
 Dual

voltage coils not available in modified starters or
in starter sizes 5–8.
conduit hubs and conversion instructions, see
page 8/88.

 For

Siemens Industry, Inc.
Industrial Controls Catalog

Disc
Amp
Rating
30
30
60
60
100
100
200
200

NEMA 1

NEMA 4/4X Stainless

NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight, Dust-tight
Corrosion Resistant

Catalog
Number
25CP92W*81
25DP92W*81
25EP92W*81
25FP92W*81
25GP92W*81
25HP92W*81
25IP92W*81
25JP92W*81

Catalog
Number
25CP92F*81
25DP92F*81
25EP92F*81
25FP92F*81
25GP92F*81
25HP92F*81
25IP92F*81
25JP92F*81

Catalog
Number
25CP92B*81
25DP92B*81
25EP92B*81
25FP92B*81
25GP92B*81
25HP92B*81
25IP92B*81
25JP92B*81

List
Price $

 Enclosure

is NEMA Type 4 (painted steel).
coil 100-250V AC 50/60Hz, or DC,
H coil 150-500V AC 50/60Hz, or DC
 Only available
F coil 100-250V AC 50/60Hz, or DC
F

Product Category: NEMA

List
Price $

NEMA 12
NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight

List
Price $

Catalog
Number
25CP92N*81
25DP92N*81
25EP92N*81
25FP92N*81
25GP92N*81
25HP92N*81
25IP92N*81
25JP92N*81

List
Price $

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

8/29

Combination Reversing Heavy Duty Starters

MCP Type, Class 26
Selection

Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/123.
Wiring Diagrams see page 8/135.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Standard Width Enclosure with Solid State Overload, 3-Phase, 3-Pole
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

Motor
Circuit
200 230 460 575 NEMA Half Interruter
Volts Volts Volts Volts Size Size ETI Amps
1
1
⁄2
⁄2
1
1
0
— 3
2
2
5
5
0
— 10
3
3
—
—
0
— 25
1
1
⁄2
⁄2
1
1
1
— 3
2
2
5
5
1
— 10
3
3
71⁄2
10
1
— 25
71⁄2
71⁄2
10
—
1
— 30
—
—
15
15
—
13⁄4 40
10
15
25
25
2
— 50
15
20
30
30
—
21⁄2 100
25
30
50
50
3
— 100
30
40
75
75
—
31⁄2 125
40
50
100 100 4
— 150
50
75
150 200 5
— 250
75
100 200 —
5
— 400
100 125 250 300 6
— 400
150 200 400 400 6
— 600
—
250 500 500 7
— 800
—
300 600 600 7
— 1000
—
400 800 800 8
— 1200
—
450 900 900 8
— 1600

Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
160–630
400–1220
400–1220
400–1220
400–1220

Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B
—
—
—
—
A1+CT
A1+CT
A1+CT
A1+CT

Catalog
List
Number
Price $
26CUB92B*
26CUC92B*
26CUD92B*
26DUB92B*
26DUC92B*
26DUD92B*
26DUE92B*
26EUE92B*
26FUF92B*
26GUG92B*
26HUG92B*
26IUH92B*
26JUH92B*
26LPT92B*
26LPU92B*
26MPW92B*
26MPX92B*
26NUV92B*
26NUY92B*
26PUW92B*
26PUZ92B*

NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight,
Watertight, Dust-tight
NEMA 3 & 4

NEMA 12
NEMA 3/3R

Corrosion Resistant
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Div. 1 and Div. 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

Industrial Use
Weatherproof
(Field Convertible to 3/3R)

Catalog
List
Number
Price $
26CUB92W*
26CUC92W*
26CUD92W*
26DUB92W*
26DUC92W*
26DUD92W*
26DUE92W*
26EUE92W*
26FUF92W*
26GUG92W*
26HUG92W*
26IUH92W*
26JUH92W*
26LPT92E*
26LPU92E*
26MPW92E*
26MPX92E*
—
—
—
—
—
—
—
—

Catalog
List
Number
Price $
26CUB92H*
26CUC92H*
26CUD92H*
26DUB92H*
26DUC92H*
26DUD92H*
26DUE92H*
26EUE92H*
26FUF92H*
26GUG92H*
26HUG92H*
26IUH92H*
26JUH92H*
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

Catalog
List
Number
Price $
26CUB92N*
26CUC92N*
26CUD92N*
26DUB92N*
26DUC92N*
26DUD92N*
26DUE92N*
26EUE92N*
26FUF92N*
26GUG92N*
26HUG92N*
26IUH92N*
26JUH92N*
26LPT92N*
26LPU92N*
26MPW92N*
26MPX92N*
26NUV92N*
26NUY92N*
26PUW92N*
26PUZ92N*

26CP92HA*81
26CP92HB*81
26CP92HC*81
26DP92HA*81
26DP92HB*81
26DP92HD*81
26DP92HE*81
26EP92HF*81
26EP92HG*81
26FP92HH*81
26FP92HJ*81
26GP92HK*81
26GP92HL*81
26HP92HM*81
26HP92HN*81
26IP92HP*81
26JP92HR*81

26CP92NA*81
26CP92NB*81
26CP92NC*81
26DP92NA*81
26DP92NB*81
26DP92ND*81
26DP92NE*81
26EP92NF*81
26EP92NG*81
26FP92NH*81
26FP92NJ*81
26GP92NK*81
26GP92NL*81
26HP92NM*81
26HP92NN*81
26IP92NP*81
26JP92NR*81

Catalog
List
Number
Price $
26CUB92F*
26CUC92F*
26CUD92F*
26DUB92F*
26DUC92F*
26DUD92F*
26DUE92F*
26EUE92F*
26FUF92F*
26GUG92F*
26HUG92F*
26IUH92F*
26JUH92F*
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

Standard Width Enclosure with Ambient Compensated Bimetal Overload, 3-Phase, 3-Pole
1
⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
10
10
15
—
25
30
40

1
⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
15
15
20
—
30
40
50

1
3
5
1
3
7 1⁄2
10
15
—
20
25
30
—
30
50
75
100

1
3
5
1
3
7 1⁄2
10
15
—
20
25
30
—
30
50
75
100

0
0
0
1
1
1
1
—
—
2
2
—
—
3
3
—
4

—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
—
—
31⁄2
—

3
10
25
3
10
25
30
40
50
40
50
50
100
50
100
125
150

18
18
18
27
27
27
27
40
40
45
45
60
60
90
90
115
135

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
 Dual

voltage coils not available in modified starters or
in starter sizes 5–8.

8/30

26CP92BA*81
26CP92BB*81
26CP92BC*81
26DP92BA*81
26DP92BB*81
26DP92BD*81
26DP92BE*81
26EP92BF*81
26EP92BG*81
26FP92BH*81
26FP92BJ*81
26GP92BK*81
26GP92BL*81
26HP92BM*81
26HP92BN*81
26IP92BP*81
26JP92BR*81

26CP92WA*81
26CP92WB*81
26CP92WC*81
26DP92WA*81
26DP92WB*81
26DP92WD*81
26DP92WE*81
26EP92WF*81
26EP92WG*81
26FP92WH*81
26FP92WJ*81
26GP92WK*81
26GP92WL*81
26HP92WM*81
26HP92WN*81
26IP92WP*81
26JP92WR*81

 For

conduit hubs and conversion instructions, see
page 8/88.
 Enclosure is NEMA Type 4 (painted steel).
 F coil 100-250V AC 50/60Hz, or DC,
H coil 150-500V AC 50/60Hz, or DC

Product Category: NEMA

26CP92FA*81
26CP92FB*81
26CP92FC*81
26DP92FA*81
26DP92FB*81
26DP92FD*81
26DP92FE*81
26EP92FF*81
26EP92FG*81
26FP92FH*81
26FP92FJ*81
26GP92FK*81
26GP92FL*81
26HP92FM*81
26HP92FN*81
26IP92FP*81
26JP92FR*81
 Only

available
F coil 100-250V AC 50/60Hz, or DC
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

 Enclosed

Siemens Industry, Inc.
Industrial Controls Catalog

Two Speed Heavy Duty Starters

Features and Benefits
General

Features
▪
▪
▪
▪

Rugged Industrial Design
Dual Voltage, Dual Frequency Coils
Compact Design
Snap-On Front Removable Auxiliary
Contacts

▪ Electrical and Mechanical Interlocks
▪ Half Sizes — Space and Cost Savings
▪ Industrial Type Disconnect
Operating Handle
▪ Visible Blade Disconnect Thru Size 4
▪ Adjustable Motor Circuit Protector
▪ 100,000 Amp Fault Protection with
MCP or Class R Fuses
▪ Pilot Device Locations identified
on All Enclosures
▪ UL Listed File #E14900
▪ CSA Certified File #LR6535

Applications
Multi-speed magnetic starters
automatically reconnect multi-speed
motor windings for the desired speed in
response to a signal received from push
button stations or other pilot devices.
These starters are available for two
speed motors.

Consequent Pole multi-speed motors
having two speeds on a single winding
(consequent pole) require a starter
which reconnects the motor leads to
half the number of effective motor
poles at the high speed point. In this
type of motor, the low speed is one
half the high speed.
Separate Windings motors having
separate windings for each speed
provide more varied speed
combinations in that the low speed
need not be one half the high speed.

motor is applicable to fans, blowers
and centrifugal pumps.

Constant Horsepower motors
maintain constant horsepower at all
speeds and therefore torque varies
inversely with speed. This type of
motor is applicable where the same
horsepower is required at all speeds.
The higher current required at
low speed requires derating on
starters for constant horsepower
applications. This type of motor is
applicable to metal working machines
such as drills, lathes, mills, bending
machines, punch presses, and power
wrenches.
Operation
Magnetic starters for multi-speed
applications select the desired speed
in accordance with the pilot control.
The shock to machinery upon the
reduction of speed is greater than when
the speed is increased. Therefore, the
pilot control should be wired so that the
stop button must be depressed before
dropping to a lower speed or time
delays should be used for applications
requiring full automatic operations. The
multi-speed controls are available with
the necessary interlocks or relays to
provide this type of operation.

Compelling Control requires that the
motor always be started at the lower
speed and that the push buttons be
operated in speed sequence to go to
the next higher speed. To change to a
lower speed, the stop button must be
depressed and then the push buttons
operated in speed sequence until the
desired speed is reached. Compelling
control can be added from the factory
modification section page 8/98.
Acceleration Control provides that
the motor be accelerated automatically
with timers by progressively energizing
the controls from the push button
station from the lowest to highest
speed. To change to a lower speed the
stop button is depressed and then it is
necessary to proceed as if starting from
rest. Acceleration control can be added
from the factory modification section
page 8/98.
Deceleration Control provides that
the motor be decelerated automatically
with a timer when going from high
speed to low speed. The timer allows
the motor to decelerate from high
speed to a lower speed before
automatically restarting the motor in
low speed. Deceleration control can be
added from the factory modification
section page 8/98.

These controls may be modified for
compelling or acceleration pilot control.

Selective Control permits the
operator to start the motor at any speed
and to change to a higher speed by
merely pushing a button. To change to
a lower speed it is necessary to first
depress the stop button and to then
press the proper speed button.
Selective control is a function of the
pilot control selected and requires no
starter modifications.

Open Style Two Speed Starter
(ESP100 Overload)

Starters for separate winding
motors consist of a starter unit
for each speed.
Multi-speed motor starters are available
for constant torque, variable torque and
constant horsepower motors.

Constant Torque motors maintain
constant torque at all speeds.
Horsepower varies directly with speed.
This type of motor is applicable to
conveyors, mills and similar
applications.

Open Style Two Speed Starter
(Ambient Compensated Overload)

Variable Torque motors produce a
torque characteristic which varies as
the square of the speed. This type of

Siemens Industry, Inc.
Industrial Controls Catalog

8/31

Two Speed Heavy Duty Starters

Constant or Variable Torque with Solid Overload, Class 30
Selection
Ordering Information
䊳

Coil Table

Replace the (*) with a letter from
the coil table. Dual voltage coils
are wired on high voltage unless
specified on order.

䊳

Replace the (†) with the letter that
corresponds to the correct low
speed FLA in the FLA table.

䊳

Field Modification Kits see page 8/82.

䊳

Factory Modifications see page 8/95.

䊳

Dimensions see page 8/124.

䊳

Wiring Diagrams see page 8/136.

䊳

Replacement Parts see page 8/157.

2S2W Starter
(ESP200 Overload)

60Hz Voltage

Low Speed FLA Table
Letter

24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

J
F
A
D
G
L
C
H
E

Size

FLA

OLR
Frame Size

†

0,1
0,1
0,1
0,1
0-13/4
2-3
2-3
21/2-4

0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200

A
A
A1
A1
A1
B
B
B

A
B
C
D
E
F
G
H

For other voltages and frequencies,
see Factory Modifications page 8/95.

One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)
Max Hp

200
Volts
1
⁄2
2
3
1
⁄2
2
3
71⁄2
10
10
15
25
30
40

230
Volts
3
⁄4
2
3
3
⁄4
2
3
71⁄2
10
15
20
30
40
50

Overload

460
Volts
11⁄2
5
—
11⁄2
5
10
—
15
25
30
50
75
100

575
Volts
2
5
—
11⁄2
5
10
—
15
25
30
50
75
100

NEMA
Size
0
0
0
1
1
1
1
—
2
—
3
—
4

Half
Size
—
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—

Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200

Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B

Enclosure
Open Type

NEMA 1

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Standard Auxiliary Contacts

General Purpose

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

Catalog
List
Catalog
List
Catalog
List
Catalog
List
Catalog
List
Number
Price $ Number
Price $ Number
Price $ Number
Price $ Number
Price $
30CUB†32A2V*
30CUB†32B2V*
30CUB†32W2V*
30CUB†32F2V*
30CUB†3202V*
30CUC†32A2V*
30CUC†32B2V*
30CUC†32W2V*
30CUC†32F2V*
30CUC†3202V*
30CUD†32A2V*
30CUD†32B2V*
30CUD†32W2V*
30CUD†32F2V*
30CUD†3202V*
30DUB†32A2V*
30DUB†32B2V*
30DUB†32W2V*
30DUB†32F2V*
30DUB†3202V*
30DUC†32A2V*
30DUC†32B2V*
30DUC†32W2V*
30DUC†32F2V*
30DUC†3202V*
30DUD†32A2V*
30DUD†32B2V*
30DUD†32W2V*
30DUD†32F2V*
30DUD†3202V*
30DUE†32A2V*
30DUE†32B2V*
30DUE†32W2V*
30DUE†32F2V*
30DUE†3202V*
30EUE†32A2V*
30EUE†32B2V*
30EUE†32W2V*
30EUE†32F2V*
30EUE†3202V*
30FUF†32A2V*
30FUF†32B2V*
30FUF†32W2V*
30FUF†32F2V*
30FUF†3202V*
30GUG†32A2V*
30GUG†32B2V*
30GUG†32W2V*
30GUG†32F2V*
30GUG†3202V*
30HUG†32A2V*
30HUG†32B2V*
30HUG†32W2V*
30HUG†32F2V*
30HUG†3202V*
30IUH†32A2V*
30IUH†32B2V*
30IUH†32W2V*
30IUH†32F2V*
30IUH†3202V*
30JUH†32A2V*
30JUH†32B2V*
30JUH†32W2V*
30JUH†32F2V*
30JUH†3202V*

Two Separate Windings, 3-Phase (Constant or Variable Torque)
Max Hp

200
Volts
1
⁄2
2
3
1
⁄2
2
3
71⁄2
10
10
15
25
30
40

230
Volts
3
⁄4
2
3
3
⁄4
2
3
71⁄2
10
15
20
30
40
50

Overload

460
Volts
11⁄2
5
—
11⁄2
5
10
—
15
25
30
50
75
100

575
Volts
2
5
—
11⁄2
5
10
—
15
25
30
50
75
100

NEMA
Size
0
0
0
1
1
1
1
—
2
—
3
—
4

Half
Size
—
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—

Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200

Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
 For conduit hubs and conversion instructions, see

page 8/88.

8/32

Enclosure
Open Type

NEMA 1

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Standard Auxiliary Contacts

General Purpose

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

Catalog
List
Catalog
List
Catalog
List
Catalog
List
Catalog
List
Number
Price $ Number
Price $ Number
Price $ Number
Price $ Number
Price $
30CUB†32A1V*
30CUB†32B1V*
30CUB†32W1V*
30CUB†32F1V*
30CUB†3201V*
30CUC†32A1V*
30CUC†32B1V*
30CUC†32W1V*
30CUC†32F1V*
30CUC†3201V*
30CUD†32A1V*
30CUD†32B1V*
30CUD†32W1V*
30CUD†32F1V*
30CUD†3201V*
30DUB†32A1V*
30DUB†32B1V*
30DUB†32W1V*
30DUB†32F1V*
30DUB†3201V*
30DUC†32A1V*
30DUC†32B1V*
30DUC†32W1V*
30DUC†32F1V*
30DUC†3201V*
30DUD†32A1V*
30DUD†32B1V*
30DUD†32W1V*
30DUD†32F1V*
30DUD†3201V*
30DUE†32A1V*
30DUE†32B1V*
30DUE†32W1V*
30DUE†32F1V*
30DUE†3201V*
30EUE†32A1V*
30EUE†32B1V*
30EUE†32W1V*
30EUE†32F1V*
30EUE†3201V*
30FUF†32A1V*
30FUF†32B1V*
30FUF†32W1V*
30FUF†32F1V*
30FUF†3201V*
30GUG†32A1V*
30GUG†32B1V*
30GUG†32W1V*
30GUG†32F1V*
30GUG†3201V*
30HUG†32A1V*
30HUG†32B1V*
30HUG†32W1V*
30HUG†32F1V*
30HUG†3201V*
30IUH†32A1V*
30IUH†32B1V*
30IUH†32W1V*
30IUH†32F1V*
30IUH†3201V*
30JUH†32A1V*
30JUH†32B1V*
30JUH†32W1V*
30JUH†32F1V*
30JUH†3201V*
 If motor FLA are unknown, select overload on the

basis that low speed FLA will be no greater than 50%
of high speed FLA.
 Auxiliary contacts 30C-30E 4th pole built-in
30F-30J 2 NO & 2 NC

Product Category: NEMA

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

Siemens Industry, Inc.
Industrial Controls Catalog

Two Speed Heavy Duty Starters

Constant HP with Solid Overload, Class 30
Selection

Ordering Information
䊳



High/Low Speed FLA Table

Coil Table

Replace the (*) with a letter from
the coil table. Dual voltage coils
are wired on high voltage unless
specified on order.

60Hz Voltage

䊳

Replace the (†) with the letter that
corresponds to the correct FLA in
High/Low Speed FLA Table.

䊳

Field Modification Kits see page
8/82.

䊳

Factory Modifications see page 8/95.

䊳

Dimensions see page 8/124.

䊳

Wiring Diagrams see page 8/136.

䊳

Replacement Parts see page 8/157.

Letter

24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

J
F
A
D
G
L
C
H
E

Size

FLA

OLR
Frame Size

†

0,1
0,1
0,1
0,1
0-13/4
2-3
2-3
21/2-4

0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200

A
A
A1
A1
A1
B
B
B

A
B
C
D
E
F
G
H

For other voltages and frequencies,
see Factory Modifications page 8/95.

2S2W Starter
(ESP200 Overload)

* First (†) for high speed, second (†)
for low speed. Use motor nameplate
to select FLA. If motor FLA are
unknown, select overload on the
bases that the low speed FLA will
be no greater than 50 % of high
speed FLA.

One Winding Consequent Pole, 3-Phase (Constant Horsepower)
Max Hp

Enclosure
Open Type

NEMA 1

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Standard Auxiliary Contacts

General Purpose

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

Catalog
Number

Catalog
Number

200 230 460 575 NEMA Half Catalog
Volts Volts Volts Volts Size
Size Number

List
Price $

Catalog
Number

List
Price $

List
Price $

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Price $

Catalog
Number

2

2

3

3

0

—

30CU††32A2H*

30CU††32B2H*

30CU††32W2H*

30CU††32F2H*

30CU††3202H*

5

5

71⁄2

71⁄2

1

—

30DU††32A2H*

30DU††32B2H*

30DU††32W2H*

30DU††32F2H*

30DU††3202H*

71⁄2

71⁄2

10

10

—

13⁄4

30EU††32A2H*

30EU††32B2H*

30EU††32W2H*

30EU††32F2H*

30EU††3202H*

71⁄2

10

20

20

2

—

30FU††32A2H*

30FU††32B2H*

30FU††32W2H*

30FU††32F2H*

30FU††3202H*

10

15

25

25

—

21⁄2

30GU††32A2H*

30GU††32B2H*

30GU††32W2H*

30GU††32F2H*

30GU††3202H*

20

25

40

40

3

—

30HU††32A2H*

30HU††32B2H*

30HU††32W2H*

30HU††32F2H*

30HU††3202H*

25

30

50

50

—

31⁄2

30IU††32A2H*

30IU††32B2H*

30IU††32W2H*

30IU††32F2H*

30IU††3202H*

30

40

75

75

4

—

30JU††32A2H*

30JU††32B2H*

30JU††32W2H*

30JU††32F2H*

30JU††3202H*

NEMA 12
NEMA 3/3R

List
Price $

Two Separate Windings, 3-Phase (Constant Horsepower)
Max Hp

Enclosure
Open Type

NEMA 1

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Standard Auxiliary Contacts

General Purpose

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

Catalog
Number

Catalog
Number

200 230 460 575 NEMA Half Catalog
Volts Volts Volts Volts Size
Size Number

List
Price $

Catalog
Number

List
Price $

List
Price $

Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Price $

Catalog
Number

2

2

3

3

0

—

30CU††32A1H*

30CU††32B1H*

30CU††32W1H*

30CU††32F1H*

30CU††3201H*

5

5

71⁄2

71⁄2

1

—

30DU††32A1H*

30DU††32B1H*

30DU††32W1H*

30DU††32F1H*

30DU††3201H*

71⁄2

71⁄2

10

10

—

13⁄4 30EU††32A1H*

30EU††32B1H*

30EU††32W1H*

30EU††32F1H*

30EU††3201H*

71⁄2

10

20

20

2

—

30FU††32A1H*

30FU††32B1H*

30FU††32W1H*

30FU††32F1H*

30FU††3201H*

10

15

25

25

—

21⁄2

30GU††32A1H*

30GU††32B1H*

30GU††32W1H*

30GU††32F1H*

30GU††3201H*

20

25

40

40

3

—

30HU††32A1H*

30HU††32B1H*

30HU††32W1H*

30HU††32F1H*

30HU††3201H*

25

30

50

50

—

31⁄2

30IU††32A1H*

30IU††32B1H*

30IU††32W1H*

30IU††32F1H*

30IU††3201H*

30

40

75

75

4

—

30JU††32A1H*

30JU††32B1H*

30JU††32W1H*

30JU††32F1H*

30JU††3201H*

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
 For conduit hubs and conversion instructions, see

page 8/88.

Siemens Industry, Inc.
Industrial Controls Catalog

 First (†) for high speed, second (†) for low speed. Use

motor nameplate information to select FLA. If motor
FLA are unknown, select overload on the basis that
low speed FLA will be no greater than 50% of high
speed FLA.

Product Category: NEMA

List
Price $

 Auxiliary contacts

30C-30E 4th pole built-in
30F-30J 2 NO & 2 NC
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

 Enclosed

8/33

Two Speed Heavy Duty Starters

Constant or Variable Torque with Ambient Compensated Bimetal Overload, Class 30
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150 (6 required)
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/106 open and 8/124 enclosed.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

2S2W starter
(Amb. Comp. Bimetal OL)

One Winding Consequent Pole, 3 Phase (Constant or Variable Torque)
Max Hp

Enclosure
Open Type

200
Volts

230
Volts

460
Volts

NEMA 1
NEMA 4/4X Stainless
NEMA 4X Fiberglass
NEMA 12
General Purpose
Watertight, Dust-tight
Watertight, Dust-tight
NEMA 3/3R
ContCorrosion Resistant
Corrosion Resistant
Industrial Use
actor
304 Stainless Steel
Weatherproof
575 Amp NEMA Half
Volts Rating Size Size Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $

3
7 1⁄2
10
10
15
25
30
40

3
7 1⁄2
10
15
20
30
40
50

5
10
15
25
30
50
75
100

5
10
15
25
30
50
75
100

18
27
40
45
60
90
115
135

0
1
—
2
—
3
—
4

—
—
13⁄4
—
21⁄2
—
31⁄2
—

30CP32A2V*81
30DP32A2V*81
30EP32A2V*81
30FP32A2V*81
30GP32A2V*81
30HP32A2V*81
30IP32A2V*81
30JG32A2V*81

30CP32B2V*81
30DP32B2V*81
30EP32B2V*81
30FP32B2V*81
30GP32B2V*81
30HP32B2V*81
30IP32B2V*81
30JG32B2V*81

30CP32W2V*81
30DP32W2V*81
30EP32W2V*81
30FP32W2V*81
30GP32W2V*81
30HP32W2V*81
30IP32W2V*81
30JG32W2V*81

30CP32F2V*81
30DP32F2V*81
30EP32F2V*81
30FP32F2V*81
30GP32F2V*81
30HP32F2V*81
30IP32F2V*81
30JG32F2V*81

30CP3202V*81
30DP3202V*81
30EP3202V*81
30FP3202V*81
30GP3202V*81
30HP3202V*81
30IP3202V*81
30JG3202V*81

Two Separate Windings, 3-Phase (Constant or Variable Torque)
Max Hp

Enclosure

200
Volts

230
Volts

Open Type
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
NEMA 12
General Purpose
Watertight, Dust-tight
Watertight, Dust-tight
NEMA 3/3R
ContCorrosion Resistant
Corrosion Resistant
Industrial Use
actor
304 Stainless Steel
Weatherproof
460 575 Amp NEMA Half
Volts Volts Rating Size Size Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $

3
7 1⁄2
10
10
15
25
30
40

3
7 1⁄2
10
15
20
30
40
50

5
10
15
25
30
50
75
100

5
10
15
25
30
50
75
100

18
27
40
45
60
90
115
135

0
1
—
2
—
3
—
4

—
—
13⁄4
—
21⁄2
—
31⁄2
—

30CP32A1V*81
30DP32A1V*81
30EP32A1V*81
30FP32A1V*81
30GP32A1V*81
30HP32A1V*81
30IP32A1V*81
30JG32A1V*81

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.

8/34

30CP32B1V*81
30DP32B1V*81
30EP32B1V*81
30FP32B1V*81
30GP32B1V*81
30HP32B1V*81
30IP32B1V*81
30JG32B1V*81

30CP32W1V*81
30DP32W1V*81
30EP32W1V*81
30FP32W1V*81
30GP32W1V*81
30HP32W1V*81
30IP32W1V*81
30JG32W1V*81

 For conduit hubs and conversion instructions,

see page 8/88.
 If motor FLA are unknown, select heater elements on

30CP32F1V*81
30DP32F1V*81
30EP32F1V*81
30FP32F1V*81
30GP32F1V*81
30HP32F1V*81
30IP32F1V*81
30JG32F1V*81

30CP3201V*81
30DP3201V*81
30EP3201V*81
30FP3201V*81
30GP3201V*81
30HP3201V*81
30IP3201V*81
30JG3201V*81

 Auxiliary

contacts
30C-30E 4th pole built-in
30F-30J 2 NO & 2 NC

the basis that low speed FLA will be no greater than
50% of high speed FLA.

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Two Speed Heavy Duty Starters

Constant HP with Ambient Compensated Bimetal Overload, Class 30
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150 (6 required)
.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/106 open and 8/124 enclosed.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

2S2W starter
(Amb. Comp. Bimetal OL)

One Winding Consequent Pole, 3-Phase (Constant Horsepower)
Max Hp

Enclosure

200
Volts

Open Type
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
NEMA 12
General Purpose
Watertight, Dust-tight
Watertight, Dust-tight
NEMA 3/3R
ContCorrosion Resistant
Corrosion Resistant
Industrial Use
actor
304 Stainless Steel
Weatherproof
230
460 575 Amp NEMA Half
Volts Volts Volts Rating Size
Size Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $

2
5
7 1⁄2
7 1⁄2
10
20
25
30

2
5
7 1⁄2
10
15
25
30
40

3
7 1⁄2
10
20
25
40
50
75

3
7 1⁄2
10
20
25
40
50
75

18
27
40
45
60
90
115
135

0
1
—
2
—
3
—
4

—
—
13⁄4
—
21⁄2
—
31⁄2
—

30CP32A2H*81
30DP32A2H*81
30EP32A2H*81
30FP32A2H*81
30GP32A2H*81
30HP32A2H*81
30IP32A2H*81
30JG32A2H*81

30CP32B2H*81
30DP32B2H*81
30EP32B2H*81
30FP32B2H*81
30GP32B2H*81
30HP32B2H*81
30IP32B2H*81
30JG32B2H*81

30CP32W2H*81
30DP32W2H*81
30EP32W2H*81
30FP32W2H*81
30GP32W2H*81
30HP32W2H*81
30IP32W2H*81
30JG32W2H*81

30CP32F2H*81
30DP32F2H*81
30EP32F2H*81
30FP32F2H*81
30GP32F2H*81
30HP32F2H*81
30IP32F2H*81
30JG32F2H*81

30CP3202H*81
30DP3202H*81
30EP3202H*81
30FP3202H*81
30GP3202H*81
30HP3202H*81
30IP3202H*81
30JG3202H*81

Two Separate Windings, 3-Phase (Constant Horsepower)
Max Hp

Enclosure

Open Type
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
NEMA 12
General Purpose
Watertight, Dust-tight
Watertight, Dust-tight
NEMA 3/3R
ContCorrosion Resistant
Corrosion Resistant
Industrial Use
actor
304 Stainless Steel
Weatherproof
200 230 460 575 Amp NEMA Half
Volts Volts Volts Volts Rating Size Size Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $

2
5
7 1⁄2
7 1⁄2
10
20
25
30

2
5
7 1⁄2
10
15
25
30
40

3
7 1⁄2
10
20
25
40
50
75

3
7 1⁄2
10
20
25
40
50
75

18
27
40
45
60
90
115
135

0
1
—
2
—
3
—
4

—
—
13⁄4
—
21⁄2
—
31⁄2
—

30CP32A1H*81
30DP32A1H*81
30EP32A1H*81
30FP32A1H*81
30GP32A1H*81
30HP32A1H*81
30IP32A1H*81
30JG32A1H*81

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.

30CP32B1H*81
30DP32B1H*81
30EP32B1H*81
30FP32B1H*81
30GP32B1H*81
30HP32B1H*81
30IP32B1H*81
30JG32B1H*81

30CP32W1H*81
30DP32W1H*81
30EP32W1H*81
30FP32W1H*81
30GP32W1H*81
30HP32W1H*81
30IP32W1H*81
30JG32W1H*81

 If motor FLA are unknown, select heater element on

the basis that low speed FLA will be no greater than
50% of high speed FLA.

30CP32F1H*81
30DP32F1H*81
30EP32F1H*81
30FP32F1H*81
30GP32F1H*81
30HP32F1H*81
30IP32F1H*81
30JG32F1H*81

30CP3201H*81
30DP3201H*81
30EP3201H*81
30FP3201H*81
30GP3201H*81
30HP3201H*81
30IP3201H*81
30JG3201H*81

 Auxiliary contacts

30C-30E 4th pole built-in
30F-30J 2 NO & 2 NC

 For conduit hubs and conversion instructions,

see page 8/88.

Siemens Industry, Inc.
Industrial Controls Catalog

Product Category: NEMA

8/35

Combination Two Speed Heavy Duty Starters

Non-Fusible, Constant or Variable Torque with Solid Overload, Class 32
Selection
Ordering Information
䊳

䊳

䊳
䊳

䊳

䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from
the coil table. Dual voltage coils
are wired on high voltage unless
specified on order.
Replace the (†) with the letter that
corresponds to the correct low
speed FLA in the FLA table.
Fuse clips see page 8/96.
Field Modification Kits see page
8/82.
Factory Modifications see page
8/95.
Dimensions see page 8/125.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.

Low Speed FLA Table

60Hz Voltage

Letter

24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

J
F
A
D
G
L
C
H
E

Size

FLA

OLR
Frame Size

†

0,1
0,1
0,1
0,1
0-13/4
2-3
2-3
21/2-4

0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200

A
A
A1
A1
A1
B
B
B

A
B
C
D
E
F
G
H

For other voltages and frequencies,
see Factory Modifications page 8/95.

One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

200
Volts
1
⁄2
2
3
1
⁄2
2
3
71⁄2
10
10
15
20
30
40

230
Volts
3
⁄4
2
3
3
⁄4
2
3
71⁄2
10
15
20
25
40
50

460
Volts
11⁄2
5
—
11⁄2
5
10
—
15
25
30
50
75
100

575
Volts
2
5
—
11⁄2
5
10
—
15
25
30
50
75
100

NEMA
Size
0
0
0
1
1
1
1
—
2
—
3
—
4

Half
Size
—
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—

Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200

Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B

Disc.
Amp
Range
30
30
30
30
30
30
60
60
60
100
100
200
200

Catalog
Number
32CUB†92B2V2*
32CUC†92B2V2*
32CUD†92B2V2*
32DUB†92B2V2*
32DUC†92B2V2*
32DUD†92B2V2*
32DUE†92B2V2*
32EUE†92B2V2*
32FUF†92B2V2*
32GUG†92B2V2*
32HUG†92B2V2*
32IUH†92B2V2*
32JUH†92B2V2*

List
Price $

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

Catalog
Number
32CUB†92W2V2*
32CUC†92W2V2*
32CUD†92W2V2*
32DUB†92W2V2*
32DUC†92W2V2*
32DUD†92W2V2*
32DUE†92W2V2*
32EUE†92W2V2*
32FUF†92W2V2*
32GUG†92W2V2*
32HUG†92W2V2*
32IUH†92W2V2*
32JUH†92W2V2*

Catalog
Number
32CUB†92F2V2*
32CUC†92F2V2*
32CUD†92F2V2*
32DUB†92F2V2*
32DUC†92F2V2*
32DUD†92F2V2*
32DUE†92F2V2*
32EUE†92F2V2*
32FUF†92F2V2*
32GUG†92F2V2*
32HUG†92F2V2*
32IUH†92F2V2*
32JUH†92F2V2*

List
Price $

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Price $

Catalog
Number
32CUB†92N2V2*
32CUC†92N2V2*
32CUD†92N2V2*
32DUB†92N2V2*
32DUC†92N2V2*
32DUD†92N2V2*
32DUE†92N2V2*
32EUE†92N2V2*
32FUF†92N2V2*
32GUG†92N2V2*
32HUG†92N2V2*
32IUH†92N2V2*
32JUH†92N2V2*

List
Price $

Two Separate Windings, 3-Phase (Constant or Variable Torque)
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

200
Volts
1
⁄2
2
3
1
⁄2
2
3
71⁄2
10
10
15
20
30
40

230
Volts
3
⁄4
2
3
3
⁄4
2
3
71⁄2
10
15
20
25
40
50

460
Volts
11⁄2
5
—
11⁄2
5
10
—
15
25
30
50
75
100

575
Volts
2
5
—
11⁄2
5
10
—
15
25
30
50
75
100

NEMA
Size
0
0
0
1
1
1
1
—
2
—
3
—
4

Half
Size
—
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—

Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200

Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
 Dual voltage coils not available in modified starters.

8/36

Disc.
Amp
Range
30
30
30
30
30
30
60
60
60
100
100
200
200

Catalog
Number
32CUB†92B1V2*
32CUC†92B1V2*
32CUD†92B1V2*
32DUB†92B1V2*
32DUC†92B1V2*
32DUD†92B1V2*
32DUE†92B1V2*
32EUE†92B1V2*
32FUF†92B1V2*
32GUG†92B1V2*
32HUG†92B1V2*
32IUH†92B1V2*
32JUH†92B1V2*

List
Price $

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

Catalog
Number
32CUB†92W1V2*
32CUC†92W1V2*
32CUD†92W1V2*
32DUB†92W1V2*
32DUC†92W1V2*
32DUD†92W1V2*
32DUE†92W1V2*
32EUE†92W1V2*
32FUF†92W1V2*
32GUG†92W1V2*
32HUG†92W1V2*
32IUH†92W1V2*
32JUH†92W1V2*

Catalog
Number
32CUB†92F1V2*
32CUC†92F1V2*
32CUD†92F1V2*
32DUB†92F1V2*
32DUC†92F1V2*
32DUD†92F1V2*
32DUE†92F1V2*
32EUE†92F1V2*
32FUF†92F1V2*
32GUG†92F1V2*
32HUG†92F1V2*
32IUH†92F1V2*
32JUH†92F1V2*

 For

List
Price $

conduit hubs and conversion instructions, see
page 8/88.
 If motor FLA are unknown, select overload on the
basis that low speed FLA will be no greater than 50%
of high speed FLA.

Product Category: NEMA

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Price $

Catalog
Number
32CUB†92N1V2*
32CUC†92N1V2*
32CUD†92N1V2*
32DUB†92N1V2*
32DUC†92N1V2*
32DUD†92N1V2*
32DUE†92N1V2*
32EUE†92N1V2*
32FUF†92N1V2*
32GUG†92N1V2*
32HUG†92N1V2*
32IUH†92N1V2*
32JUH†92N1V2*

List
Price $

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Two Speed Heavy Duty Starters

Non-Fusible, Constant Horsepower with Solid State Overload, Class 32
Selection
High/Low Speed FLA Table

Coil Table

Ordering Information
Replace the (*) with a letter from
the coil table. Dual voltage coils are
wired on high voltage unless
specified on order.
䊳 Replace the (†) with the letter that
corresponds to the correct FLA in the
High/Low Speed FLA Table.
䊳 Fuse clips see page 8/96.
䊳 Field Modification Kits see page 8/82.
䊳 Factory Modifications see page 8/95.
䊳 Dimensions see page 8/125.
䊳 Wiring Diagrams see page 8/136.
䊳 Replacement Parts see page 8/157.
䊳

60Hz Voltage

Letter

24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

For other voltages and
frequencies see Factory
Modifications page 8/95.

J
F
A
D
G
L
C
H
E

Size

FLA

OLR
Frame Size

†

0,1
0,1
0,1
0,1
0-13/4
2-3
2-3
21/2-4

0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200

A
A
A1
A1
A1
B
B
B

A
B
C
D
E
F
G
H

* First (†) for high speed, second (†)
for low speed. Use motor nameplate
to select FLA. If motor FLA are
unknown, select overload on the
bases that the low speed FLA will
be no greater than 50 % of high
speed FLA.

One Winding Consequent Pole, 3-Phase (Constant Horsepower)
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

Catalog
Number

Catalog
Number

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

200 230 460 575 NEMA Half Amp
Volts Volts Volts Volts Size
Size Range

Disc.
Frame Amp Catalog
Size Range Number

2

2

3

3

0

—

—

—

30

32CU††92B2H2*

32CU††92W2H2*

32CU††92F2H2*

32CU††92N2H2*

5

5

71⁄2

71⁄2

1

—

—

—

30

32DU††92B2H2*

32DU††92W2H2*

32DU††92F2H2*

32DU††92N2H2*

71⁄2

71⁄2

10

10

—

13⁄4

—

—

60

32EU††92B2H2*

32EU††92W2H2*

32EU††92F2H2*

32EU††92N2H2*

71⁄2

10

20

20

2

—

—

—

60

32FU††92B2H2*

32FU††92W2H2*

32FU††92F2H2*

32FU††92N2H2*

10

15

25

25

—

21⁄2

—

—

100

32GU††92B2H2*

32GU††92W2H2*

32GU††92F2H2*

32GU††92N2H2*

20

25

40

40

3

—

—

—

100

32HU††92B2H2*

32HU††92W2H2*

32HU††92F2H2*

32HU††92N2H2*

25

30

50

50

—

31⁄2

—

—

200

32IU††92B2H2*

32IU††92W2H2*

32IU††92F2H2*

32IU††92N2H2*

30

40

75

75

4

—

—

—

200

32JU††92B2H2*

32JU††92W2H2*

32JU††92F2H2*

32JU††92N2H2*

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

NEMA 12
NEMA 3/3R

Catalog
Number

Catalog
Number

List
Price $

List
Price $

List
Price $

Catalog
Number

List
Price $

Two Separate Windings, 3-Phase (Constant Horsepower)
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

Industrial Use
Weatherproof
(Field Convertible to 3/3R)

200 230 460 575 NEMA Half Amp
Volts Volts Volts Volts Size
Size Range

Disc.
Frame Amp Catalog
Size Range Number

2

2

3

3

0

—

—

—

30

32CU††92B1H2*

32CU††92W1H2*

32CU††92F1H2*

32CU††92N1H2*

5

5

71⁄2

71⁄2

1

—

—

—

30

32DU††92B1H2*

32DU††92W1H2*

32DU††92F1H2*

32DU††92N1H2*

71⁄2

71⁄2

10

10

—

13⁄4

—

—

60

32EU††92B1H2*

32EU††92W1H2*

32EU††92F1H2*

32EU††92N1H2*

71⁄2

10

20

20

2

—

—

—

60

32FU††92B1H2*

32FU††92W1H2*

32FU††92F1H2*

32FU††92N1H2*

10

15

25

25

—

21⁄2

—

—

100

32GU††92B1H2*

32GU††92W1H2*

32GU††92F1H2*

32GU††92N1H2*

20

25

40

40

3

—

—

—

100

32HU††92B1H2*

32HU††92W1H2*

32HU††92F1H2*

32HU††92N1H2*

25

30

50

50

—

31⁄2

—

—

200

32IU††92B1H2*

32IU††92W1H2*

32IU††92F1H2*

32IU††92N1H2*

30

40

75

75

4

—

—

—

200

32JU††92B1H2*

32JU††92W1H2*

32JU††92F1H2*

32JU††92N1H2*

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
 Dual voltage coils not available in modified starters.
 For conduit hubs and conversion instructions, see
page 8/88.

Siemens Industry, Inc.
Industrial Controls Catalog

List
Price $

 First

List
Price $

† for high speed, second † for low speed. Use
motor nameplate information to select FLA. If motor
FLA are unknown, select overload on the basis that
low speed FLA will be no greater than 50% of high
speed FLA.
 Enclosed starters with the ESP200 OLR will not be

Product Category: NEMA

List
Price $

Catalog
Number

List
Price $

available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

8/37

Combination Two Speed Heavy Duty Starters

Non-Fusible, Constant or Variable Torque with Ambient Compensated Bimetal Overload, Class 32
Selection
Ordering Information

Coil Table

䊳

60Hz Voltage

Replace the (*) with a letter from the coil
table. Dual voltage coils are wired on high
voltage unless specified on order.

䊳

Heater elements see page 8/150. (6 required)

䊳

Fuse clips see page 8/96.

䊳

Field Modification Kits see page 8/82.

䊳

Factory Modifications see page 8/95.

䊳

Dimensions see page 8/125.

䊳

Wiring Diagrams see page 8/136.

䊳

Replacement Parts see page 8/157.

Letter

24 Separate Control
120 Separate Control
110–120/220–240

J
F

A
200–208
D
220–240
G
277
L

220–240/440–480
C
440–480
H
575–600
E
For other voltages and frequencies, see Factory
Modifications page 8/95.

One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)
Max Hp

Enclosure

200
230
Volts Volts

3
7 1⁄2
10
10
15
20
30
40

3
7 1⁄2
10
15
20
25
40
50

460
Volts

575
Volts

Contactor
Amp
NEMA Half
Rating Size
Size

5
10
15
25
30
50
75
100

5
10
15
25
30
50
75
100

18
27
40
45
60
90
115
135

0
1
—
2
—
3
—
4

—
—
13⁄4
—
21⁄2
—
31⁄2
—

NEMA 1

NEMA 4/4X Stainless NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight, Dust-tight
Corrosion Resistant

Disc
Amp
Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number

30
30
60
60
100
100
200
200

32CP92B2V2*81
32DP92B2V2*81
32EP92B2V2*81
32FP92B2V2*81
32GP92B2V2*81
32HP92B2V2*81
32IP92B2V2*81
32JP92B2V2*81

32CP92W2V2*81
32DP92W2V2*81
32EP92W2V2*81
32FP92W2V2*81
32GP92W2V2*81
32HP92W2V2*81
32IP92W2V2*81
32JP92W2V2*81

NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight

List Price $ Catalog Number

32CP92F2V2*81
32DP92F2V2*81
32EP92F2V2*81
32FP92F2V2*81
32GP92F2V2*81
32HP92F2V2*81
32IP92F2V2*81
32JP92F2V2*81

List Price $

32CP92N2V2*81
32DP92N2V2*81
32EP92N2V2*81
32FP92N2V2*81
32GP92N2V2*81
32HP92N2V2*81
32IP92N2V2*81
32JP92N2V2*81

Two Separate Windings, 3-Phase (Constant or Variable Torque)
Max Hp

200
230
Volts Volts

3
7 1⁄2
10
10
15
20
30
40

3
7 1⁄2
10
15
20
25
40
50

Enclosure

460
Volts

5
10
15
25
30
50
75
100

575
Volts

5
10
15
25
30
50
75
100

Contactor
Amp
NEMA Half
Rating Size Size

18
27
40
45
60
90
115
135

0
1
—
2
—
3
—
4

—
—
13⁄4
—
21⁄2
—
31⁄2
—

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.

8/38

NEMA 1

NEMA 4/4X Stainless NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight, Dust-tight
Corrosion Resistant

32CP92W1V2*81
32DP92W1V2*81
32EP92W1V2*81
32FP92W1V2*81
32GP92W1V2*81
32HP92W1V2*81
32IP92W1V2*81
32JP92W1V2*81

32CP92F1V2*81
32DP92F1V2*81
32EP92F1V2*81
32FP92F1V2*81
32GP92F1V2*81
32HP92F1V2*81
32IP92F1V2*81
32JP92F1V2*81

Disc
Amp
Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number

30
30
60
60
100
100
200
200

32CP92B1V2*81
32DP92B1V2*81
32EP92B1V2*81
32FP92B1V2*81
32GP92B1V2*81
32HP92B1V2*81
32IP92B1V2*81
32JP92B1V2*81

NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight

List Price $ Catalog Number

List Price $

32CP92N1V2*81
32DP92N1V2*81
32EP92N1V2*81
32FP92N1V2*81
32GP92N1V2*81
32HP92N1V2*81
32IP92N1V2*81
32JP92N1V2*81

 Dual voltage coils not available in modified starters.
 For conduit hubs and conversion instructions, see

page 8/88.

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Two Speed Heavy Duty Starters

Non-Fusible, Constant Horsepower with Ambient Compensated Bimetal Overload, Class 32
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. (6 Required)
Fuse clips see page 8/96.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/125.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

One Winding Consequent Pole, 3-Phase (Constant Horsepower)
Max Hp

Enclosure

200
230
Volts Volts

2
5
7 1⁄2
7 1⁄2
10
20
25
30

2
5
7 1⁄2
10
15
25
30
40

460
Volts

3
7 1⁄2
10
20
25
40
50
75

575
Volts

3
7 1⁄2
10
20
25
40
50
75

NEMA 1

NEMA 4/4X Stainless NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight, Dust-tight
Corrosion Resistant

Contactor
Disc
Amp
NEMA Half Amp
Rating
Size
Size Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number

18
27
40
45
60
90
115
135

0
1
—
2
—
3
—
4

—
—
13⁄4
—
21⁄2
—
31⁄2
—

30
30
60
60
100
100
200
200

32CP92B2H2*81
32DP92B2H2*81
32EP92B2H2*81
32FP92B2H2*81
32GP92B2H2*81
32HP92B2H2*81
32IP92B2H2*81
32JP92B2H2*81

32CP92W2H2*81
32DP92W2H2*81
32EP92W2H2*81
32FP92W2H2*81
32GP92W2H2*81
32HP92W2H2*81
32IP92W2H2*81
32JP92W2H2*81

NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight

List Price $ Catalog Number

32CP92F2H2*81
32DP92F2H2*81
32EP92F2H2*81
32FP92F2H2*81
32GP92F2H2*81
32HP92F2H2*81
32IP92F2H2*81
32JP92F2H2*81

List Price $

32CP92N2H2*81
32DP92N2H2*81
32EP92N2H2*81
32FP92N2H2*81
32GP92N2H2*81
32HP92N2H2*81
32IP92N2H2*81
32JP92N2H2*81

Two Separate Windings, 3-Phase (Constant Horsepower)
Max Hp

Enclosure

200
230
Volts Volts

2
5
7 1⁄2
7 1⁄2
10
20
25
30

2
5
7 1⁄2
10
15
25
30
40

460
Volts

575
Volts

3
7 1⁄2
10
20
25
40
50
75

3
7 1⁄2
10
20
25
40
50
75

Contactor
Amp
NEMA Half
Rating
Size
Size

18
27
40
45
60
90
115
135

0
1
—
2
—
3
—
4

—
—
13⁄4
—
21⁄2
—
31⁄2
—

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.

Siemens Industry, Inc.
Industrial Controls Catalog

NEMA 1

NEMA 4/4X Stainless NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight, Dust-tight
Corrosion Resistant

32CP92W1H2*81
32DP92W1H2*81
32EP92W1H2*81
32FP92W1H2*81
32GP92W1H2*81
32HP92W1H2*81
32IP92W1H2*81
32JP92W1H2*81

32CP92F1H2*81
32DP92F1H2*81
32EP92F1H2*81
32FP92F1H2*81
32GP92F1H2*81
32HP92F1H2*81
32IP92F1H2*81
32JP92F1H2*81

Disc
Amp
Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number

30
30
60
60
100
100
200
200

32CP92B1H2*81
32DP92B1H2*81
32EP92B1H2*81
32FP92B1H2*81
32GP92B1H2*81
32HP92B1H2*81
32IP92B1H2*81
32JP92B1H2*81

NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight

List Price $ Catalog Number

List Price $

32CP92N1H2*81
32DP92N1H2*81
32EP92N1H2*81
32FP92N1H2*81
32GP92N1H2*81
32HP92N1H2*81
32IP92N1H2*81
32JP92N1H2*81

 Dual

voltage coils not available in modified starters.
conduit hubs and conversion instructions, see
page 8/88.

 For

Product Category: NEMA

8/39

Combination Two Speed Heavy Duty Starters

MCP Type, Constant or Variable Torque with Solid State Overload, Class 32
Selection
Ordering Information
䊳

䊳

Coil Table

Replace the (*) with a letter from the
coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Replace the (†) with the letter that
corresponds to the correct low speed
FLA in the FLA table.

䊳

Field Modification Kits see page
8/82.

䊳

Factory Modifications see page 8/95.

䊳

Dimensions see page 8/125.

䊳

Wiring Diagrams see page 8/136.

䊳

Replacement Parts see page 8/157.

Low Speed FLA Table

60Hz Voltage

Letter

24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

J
F
A
D
G
L
C
H
E

Size

FLA

OLR
Frame Size

†

0,1
0,1
0,1
0,1
0-13/4
2-3
2-3
21/2-4

0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200

A
A
A1
A1
A1
B
B
B

A
B
C
D
E
F
G
H

For other voltages and frequencies, see
Factory Modifications page 8/95.

One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

Motor
Circuit
200 230 460 575 NEMA Half Interruter
Volts Volts Volts Volts Size Size ETI Amps
1
3
⁄2
⁄4
11⁄2
2
0
— 3
2
2
5
5
0
— 10
3
3
—
—
0
— 25
1
3
⁄2
⁄4
11⁄2
11⁄2
1
— 3
2
2
5
5
1
— 10
3
3
10
10
1
— 25
71⁄2
71⁄2
—
—
1
— 30
—
—
15
15
—
13⁄4 40
10
15
25
25
2
— 50
15
20
30
30
—
21⁄2 100
25
30
50
50
3
— 100
30
40
75
75
—
31⁄2 125
40
50
100 100 4
— 150

Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200

Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B

Catalog
Number
32CUB†92B2V*
32CUC†92B2V*
32CUD†92B2V*
32DUB†92B2V*
32DUC†92B2V*
32DUD†92B2V*
32DUE†92B2V*
32EUE†92B2V*
32FUF†92B2V*
32GUG†92B2V*
32HUG†92B2V*
32IUH†92B2V*
32JUH†92B2V*

List
Price $

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

Catalog
Number
32CUB†92W2V*
32CUC†92W2V*
32CUD†92W2V*
32DUB†92W2V*
32DUC†92W2V*
32DUD†92W2V*
32DUE†92W2V*
32EUE†92W2V*
32FUF†92W2V*
32GUG†92W2V*
32HUG†92W2V*
32IUH†92W2V*
32JUH†92W2V*

Catalog
Number
32CUB†92F2V*
32CUC†92F2V*
32CUD†92F2V*
32DUB†92F2V*
32DUC†92F2V*
32DUD†92F2V*
32DUE†92F2V*
32EUE†92F2V*
32FUF†92F2V*
32GUG†92F2V*
32HUG†92F2V*
32IUH†92F2V*
32JUH†92F2V*

List
Price $

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Price $

Catalog
Number
32CUB†92N2V*
32CUC†92N2V*
32CUD†92N2V*
32DUB†92N2V*
32DUC†92N2V*
32DUD†92N2V*
32DUE†92N2V*
32EUE†92N2V*
32FUF†92N2V*
32GUG†92N2V*
32HUG†92N2V*
32IUH†92N2V*
32JUH†92N2V*

List
Price $

Two Separate Windings, 3-Phase (Constant or Variable Torque)
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

Motor
Circuit
200 230 460 575 NEMA Half Interruter
Volts Volts Volts Volts Size Size ETI Amps
1
3
⁄2
⁄4
11⁄2
2
0
— 3
2
2
5
5
0
— 10
3
3
—
—
0
— 25
1
3
⁄2
⁄4
11⁄2
11⁄2
1
— 3
2
2
5
5
1
— 10
3
3
10
10
1
— 25
71⁄2
71⁄2
—
—
1
— 30
10
10
15
15
—
13⁄4 40
10
15
25
25
2
— 50
15
20
30
30
—
21⁄2 100
25
30
50
50
3
— 100
30
40
75
75
—
31⁄2 125
40
50
100 100 4
— 150

Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
 Dual voltage coils not available in modified starters.

8/40

Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B

Catalog
Number
32CUB†92B1V*
32CUC†92B1V*
32CUD†92B1V*
32DUB†92B1V*
32DUC†92B1V*
32DUD†92B1V*
32DUE†92B1V*
32EUE†92B1V*
32FUF†92B1V*
32GUG†92B1V*
32HUG†92B1V*
32IUH†92B1V*
32JUH†92B1V*

List
Price $

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

Catalog
Number
32CUB†92W1V*
32CUC†92W1V*
32CUD†92W1V*
32DUB†92W1V*
32DUC†92W1V*
32DUD†92W1V*
32DUE†92W1V*
32EUE†92W1V*
32FUF†92W1V*
32GUG†92W1V*
32HUG†92W1V*
32IUH†92W1V*
32JUH†92W1V*

Catalog
Number
32CUB†92F1V*
32CUC†92F1V*
32CUD†92F1V*
32DUB†92F1V*
32DUC†92F1V*
32DUD†92F1V*
32DUE†92F1V*
32EUE†92F1V*
32FUF†92F1V*
32GUG†92F1V*
32HUG†92F1V*
32IUH†92F1V*
32JUH†92F1V*

 For

List
Price $

conduit hubs and conversion instructions, see
page 8/88.
motor FLA are unknown, select overload on the
basis that low speed FLA will be no greater than 50%
of high speed FLA.

 If

Product Category: NEMA

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Price $

Catalog
Number
32CUB†92N1V*
32CUC†92N1V*
32CUD†92N1V*
32DUB†92N1V*
32DUC†92N1V*
32DUD†92N1V*
32DUE†92N1V*
32EUE†92N1V*
32FUF†92N1V*
32GUG†92N1V*
32HUG†92N1V*
32IUH†92N1V*
32JUH†92N1V*

List
Price $

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Two Speed Heavy Duty Starters

MCP Type, Constant Horsepower with Solid State Overload, Class 32
Selection

䊳

䊳

䊳
䊳
䊳
䊳
䊳

Ordering Information

Coil Table

Replace the (*) with a letter from
the coil table. Dual voltage coils are
wired on high voltage unless specified
on order.
Replace the (†) with the letter that
corresponds to the correct FLA in the
High/Low Speed FLA table.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/125.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.

60Hz Voltage

High/Low Speed FLA Table
Letter

24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

For other voltages and
frequencies see Factory
Modifications page 8/95.

J
F
A
D
G
L
C
H
E

Size

FLA

OLR
Frame Size

†

0,1
0,1
0,1
0,1
0-13/4
2-3
2-3
21/2-4

0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200

A
A
A1
A1
A1
B
B
B

A
B
C
D
E
F
G
H

* First (†) for high speed, second (†)
for low speed. Use motor nameplate
to select FLA. If motor FLA are
unknown, select overload on the
bases that the low speed FLA will
be no greater than 50 % of high
speed FLA.

One Winding Consequent Pole, 3-Phase (Constant Horsepower)
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

Catalog
Number

Catalog
Number

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

Motor
Circuit
200 230 460 575 NEMA Half Interruter
Volts Volts Volts Volts Size Size ETI Amps

Amp
Range

Frame Catalog
Size Number

2

2

3

3

0

—

10

—

A or A1 32CU††92B2H*

32CU††92W2H*

32CU††92F2H*

32CU††92N2H*

5

5

71⁄2

71⁄2

1

—

25

—

A or A1 32DU††92B2H*

32DU††92W2H*

32DU††92F2H*

32DU††92N2H*

71⁄2

71⁄2

10

10

—

13⁄4

40

—

A1

32EU††92B2H*

32EU††92W2H*

32EU††92F2H*

32EU††92N2H*

71⁄2

10

20

20

2

—

50

—

B

32FU††92B2H*

32FU††92W2H*

32FU††92F2H*

32FU††92N2H*

10

15

25

25

—

21⁄2

100

—

B

32GU††92B2H*

32GU††92W2H*

32GU††92F2H*

32GU††92N2H*

20

25

40

40

3

—

100

—

B

32HU††92B2H*

32HU††92W2H*

32HU††92F2H*

32HU††92N2H*

25

30

50

50

—

31⁄2

125

—

B

32IU††92B2H*

32IU††92W2H*

32IU††92F2H*

32IU††92N2H*

30

40

75

75

4

—

150

—

B

32JU††92B2H*

32JU††92W2H*

32JU††92F2H*

32JU††92N2H*

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight
Corrosion Resistant

NEMA 12
NEMA 3/3R

Catalog
Number

Catalog
Number

List
Price $

List
Price $

List
Price $

Catalog
Number

List
Price $

Two Separate Windings, 3-Phase (Constant Horsepower)
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

Industrial Use
Weatherproof
(Field Convertible to 3/3R)

Motor
Circuit
200 230 460 575 NEMA Half Interruter
Volts Volts Volts Volts Size Size ETI Amps

Amp
Range

Frame Catalog
Size Number

2

2

3

3

0

—

10

—

A or A1 32CU††92B1H*

32CU††92W1H*

32CU††92F1H*

32CU††92N1H*

5

5

71⁄2

71⁄2

1

—

25

—

A or A1 32DU††92B1H*

32DU††92W1H*

32DU††92F1H*

32DU††92N1H*

71⁄2

71⁄2

10

10

—

13⁄4

40

—

A1

32EU††92B1H*

32EU††92W1H*

32EU††92F1H*

32EU††92N1H*

71⁄2

10

20

20

2

—

50

—

B

32FU††92B1H*

32FU††92W1H*

32FU††92F1H*

32FU††92N1H*

10

15

25

25

—

21⁄2

100

—

B

32GU††92B1H*

32GU††92W1H*

32GU††92F1H*

32GU††92N1H*

20

25

40

40

3

—

100

—

B

32HU††92B1H*

32HU††92W1H*

32HU††92F1H*

32HU††92N1H*

25

30

50

50

—

31⁄2

125

—

B

32IU††92B1H*

32IU††92W1H*

32IU††92F1H*

32IU††92N1H*

30

40

75

75

4

—

150

—

B

32JU††92B1H*

32JU††92W1H*

32JU††92F1H*

32JU††92N1H*

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
 Dual voltage coils not available in modified starters.
 For conduit hubs and conversion instructions, see
page 8/88.

Siemens Industry, Inc.
Industrial Controls Catalog



List
Price $

First † for high speed, second † for low speed. Use
motor nameplate information to select FLA. If motor
FLA are unknown, select overload on the basis that
low speed FLA will be no greater than 50% of high
speed FLA.

Product Category: NEMA

List
Price $

List
Price $

Catalog
Number

List
Price $

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

8/41

Combination Two Speed Heavy Duty Starters

MCP Type, Constant or Variable Torque w/Ambient Compensated Bimetal Overload, Class 32
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. (6 Required)
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/125.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)
Max Hp

Enclosure

200
230 460
575 NEMA Half Motor Circuit
Volts Volts Volts Volts Size Size Interrupter ETI Amps
1

⁄2
1
3
1 1⁄2
1
3
7 1⁄2
—
10
—
10
10
15
—
25
30
40

1

⁄2
1
1
1
3
3
3
5
5
1
1 ⁄2
1
1
1
3
3
1
7 1⁄2
3
7 ⁄2
1
7 ⁄2 10
10
—
15
15
10
—
—
—
20
20
15
25
25
15
30
30
20
—
—
—
30
30
30
50
50
40
75
75
50
100 100

0
0
0
1
1
1
1
—
—
2
2
—
—
3
3
—
4

—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
—
—
31⁄2
—

3
10
25
3
10
25
30
40
50
40
50
50
100
50
100
125
150

NEMA 1

NEMA 4/4X Stainless

NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight, Dust-tight
Corrosion Resistant

Catalog Number List Price $ Catalog Number List Price $ Catalog Number

32CP92B2VA*81
32CP92B2VB*81
32CP92B2VC*81
32DP92B2VA*81
32DP92B2VB*81
32DP92B2VD*81
32DP92B2VE*81
32EP92B2VF*81
32EP92B2VG*81
32FP92B2VH*81
32FP92B2VJ*81
32GP92B2VK*81
32GP92B2VL*81
32HP92B2VM*81
32HP92B2VN*81
32IP92B2VP*81
32JP92B2VR*81

32CP92W2VA*81
32CP92W2VB*81
32CP92W2VC*81
32DP92W2VA*81
32DP92W2VB*81
32DP92W2VD*81
32DP92W2VE*81
32EP92W2VF*81
32EP92W2VG*81
32FP92W2VH*81
32FP92W2VJ*81
32GP92W2VK*81
32GP92W2VL*81
32HP92W2VM*81
32HP92W2VN*81
32IP92W2VP*81
32JP92W2VR*81

NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight

List Price $ Catalog Number

32CP92F2VA*81
32CP92F2VB*81
32CP92F2VC*81
32DP92F2VA*81
32DP92F2VB*81
32DP92F2VD*81
32DP92F2VE*81
32EP92F2VF*81
32EP92F2VG*81
32FP92F2VH*81
32FP92F2VJ*81
32GP92F2VK*81
32GP92F2VL*81
32HP92F2VM*81
32HP92F2VN*81
32IP92F2VP*81
32JP92F2VR*81

List Price $

32CP92N2VA*81
32CP92N2VB*81
32CP92N2VC*81
32DP92N2VA*81
32DP92N2VB*81
32DP92N2VD*81
32DP92N2VE*81
32EP92N2VF*81
32EP92N2VG*81
32FP92N2VH*81
32FP92N2VJ*81
32GP92N2VK*81
32GP92N2VL*81
32HP92N2VM*81
32HP92N2VN*81
32IP92N2VP*81
32JP92N2VR*81

Two Separate Windings, 3-Phase (Constant or Variable Torque)
Max Hp

Enclosure

200
230
460
575 NEMA Half Motor Circuit
Volts Volts Volts Volts Size Size Interrupter ETI Amps
1

⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
10
10
15
—
25
30
40

1

⁄2
1
1
1
3
3
3
5
5
1
⁄2
1
1
1
3
3
7 1⁄2
3
7 1⁄2
7 1⁄2 10
10
—
15
15
10
—
—
—
20
20
15
25
25
15
30
30
20
—
—
—
30
30
30
50
50
40
75
75
50 100
100

0
0
0
1
1
1
1
—
—
2
2
—
—
3
3
—
4

—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
—
—
31⁄2
—

8/42

NEMA 4/4X Stainless NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight, Dust-tight
Corrosion Resistant

Catalog Number List Price $ Catalog Number List Price $ Catalog Number

3
10
25
3
10
25
30
40
50
40
50
50
100
50
100
125
150

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.

NEMA 1

32CP92B1VA*81
32CP92B1VB*81
32CP92B1VC*81
32DP92B1VA*81
32DP92B1VB*81
32DP92B1VD*81
32DP92B1VE*81
32EP92B1VF*81
32EP92B1VG*81
32FP92B1VH*81
32FP92B1VJ*81
32GP92B1VK*81
32GP92B1VL*81
32HP92B1VM*81
32HP92B1VN*81
32IP92B1VP*81
32JP92B1VR*81

32CP92W1VA*81
32CP92W1VB*81
32CP92W1VC*81
32DP92W1VA*81
32DP92W1VB*81
32DP92W1VD*81
32DP92W1VE*81
32EP92W1VF*81
32EP92W1VG*81
32FP92W1VH*81
32FP92W1VJ*81
32GP92W1VK*81
32GP92W1VL*81
32HP92W1VM*81
32HP92W1VN*81
32IP92W1VP*81
32JP92W1VR*81

32CP92F1VA*81
32CP92F1VB*81
32CP92F1VC*81
32DP92F1VA*81
32DP92F1VB*81
32DP92F1VD*81
32DP92F1VE*81
32EP92F1VF*81
32EP92F1VG*81
32FP92F1VH*81
32FP92F1VJ*81
32GP92F1VK*81
32GP92F1VL*81
32HP92F1VM*81
32HP92F1VN*81
32IP92F1VP*81
32JP92F1VR*81

NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight

List Price $ CatalogNumber

List Price $

32CP92N1VA*81
32CP92N1VB*81
32CP92N1VC*81
32DP92N1VA*81
32DP92N1VB*81
32DP92N1VD*81
32DP92N1VE*81
32EP92N1VF*81
32EP92N1VG*81
32FP92N1VH*81
32FP92N1VJ*81
32GP92N1VK*81
32GP92N1VL*81
32HP92N1VM*81
32HP92N1VN*81
32IP92N1VP*81
32JP92N1VR*81

 Dual

voltage coils not available in modified starters.
conduit hubs and conversion instructions, see
page 8/88.

 For

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Two Speed Heavy Duty Starters

MCP, Constant Horsepower w/Ambient Compensated Bimetal Overload, Class 32
Selection
Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. (6 Required)
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/125.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

One Winding Consequent Pole, 3-Phase (Constant Horsepower)
Max Hp

Enclosure

200
230
460
575 NEMA Half
Volts Volts Volts Volts Size Size
1

⁄2
1 1⁄2
2
1
⁄2
1 1⁄2
3
5
—
7 1⁄2
—
7 1⁄2
—
10
20
25
30

1

⁄2
1 1⁄2
2
1
⁄2
1 1⁄2
3
5
—
7 1⁄2
7 1⁄2
10
—
15
25
30
40

1
3
—
1
3
7 1⁄2
—
10
—
15
20
30
30
40
50
75

1
3
—
1
3
7 1⁄2
—
10
—
20
—
30
40
—
50
75

0
0
0
1
1
1
1
—
—
2
2
—
3
3
—
4

—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
—
—
31⁄2
—

Motor Circuit
Interrupter ETI Amps

3
10
25
3
10
25
30
40
50
40
50
50
50
100
125
150

NEMA 1

NEMA 4/4X Stainless NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight, Dust-tight
Corrosion Resistant

Catalog Number List Price $ Catalog Number List Price $ Catalog Number

32CP92B2HA*81
32CP92B2HB*81
32CP92B2HC*81
32DP92B2HA*81
32DP92B2HB*81
32DP92B2HD*81
32DP92B2HE*81
32EP92B2HF*81
32EP92B2HG*81
32FP92B2HH*81
32FP92B2HJ*81
32GP92B2HK*81
32HP92B2HM*81
32HP92B2HN*81
32IP92B2HP*81
32JP92B2HR*81

32CP92W2HA*81
32CP92W2HB*81
32CP92W2HC*81
32DP92W2HA*81
32DP92W2HB*81
32DP92W2HD*81
32DP92W2HE*81
32EP92W2HF*81
32EP92W2HG*81
32FP92W2HH*81
32FP92W2HJ*81
32GP92W2HK*81
32HP92W2HM*81
32HP92W2HN*81
32IP92W2HP*81
32JP92W2HR*81

NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight

List Price $ Catalog Number

32CP92F2HA*81
32CP92F2HB*81
32CP92F2HC*81
32DP92F2HA*81
32DP92F2HB*81
32DP92F2HD*81
32DP92F2HE*81
32EP92F2HF*81
32EP92F2HG*81
32FP92F2HH*81
32FP92F2HJ*81
32GP92F2HK*81
32HP92F2HM*81
32HP92F2HN*81
32IP92F2HP*81
32JP92F2HR*81

List Price $

32CP92N2HA*81
32CP92N2HB*81
32CP92N2HC*81
32DP92N2HA*81
32DP92N2HB*81
32DP92N2HD*81
32DP92N2HE*81
32EP92N2HF*81
32EP92N2HG*81
32FP92N2HH*81
32FP92N2HJ*81
32GP92N2HK*81
32HP92N2HM*81
32HP92N2HN*81
32IP92N2HP*81
32JP92N2HR*81

Two Separate Windings, 3-Phase (Constant Horsepower)
Max Hp

Enclosure

200
230
Volts Volts
1

⁄2
1 1⁄2
2
1
⁄2
1 1⁄2
3
5
—
7 1⁄2
—
7 1⁄2
—
10
20
25
30

1

⁄2
1 1⁄2
2
1
⁄2
1 1⁄2
3
5
—
7 1⁄2
7 1⁄2
10
—
15
25
30
40

460
575 NEMA Half
Volts Volts Size Size

1
3
—
1
3
7 1⁄2
—
10
—
15
20
30
30
40
50
75

1
3
—
1
3
7 1⁄2
—
10
—
20
—
30
40
—
50
75

0
0
0
1
1
1
1
—
—
2
2
—
3
3
—
4

—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
—
—
31⁄2
—

Motor Circuit
Interrupter ETI Amps

3
10
25
3
10
25
30
40
50
40
50
50
50
100
125
150

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.

Siemens Industry, Inc.
Industrial Controls Catalog

NEMA 1

NEMA 4/4X Stainless NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight, Dust-tight
Corrosion Resistant

Catalog Number List Price $ Catalog Number List Price $ Catalog Number

32CP92B1HA*81
32CP92B1HB*81
32CP92B1HC*81
32DP92B1HA*81
32DP92B1HB*81
32DP92B1HD*81
32DP92B1HE*81
32EP92B1HF*81
32EP92B1HG*81
32FP92B1HH*81
32FP92B1HJ*81
32GP92B1HK*81
32HP92B1HM*81
32HP92B1HN*81
32IP92B1HP*81
32JP92B1HR*81

32CP92W1HA*81
32CP92W1HB*81
32CP92W1HC*81
32DP92W1HA*81
32DP92W1HB*81
32DP92W1HD*81
32DP92W1HE*81
32EP92W1HF*81
32EP92W1HG*81
32FP92W1HH*81
32FP92W1HJ*81
32GP92W1HK*81
32HP92W1HM*81
32HP92W1HN*81
32IP92W1HP*81
32JP92W1HR*81

32CP92F1HA*81
32CP92F1HB*81
32CP92F1HC*81
32DP92F1HA*81
32DP92F1HB*81
32DP92F1HD*81
32DP92F1HE*81
32EP92F1HF*81
32EP92F1HG*81
32FP92F1HH*81
32FP92F1HJ*81
32GP92F1HK*81
32HP92F1HM*81
32HP92F1HN*81
32IP92F1HP*81
32JP92F1HR*81

NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight

List Price $ Catalog Number

List Price $

32CP92N1HA*81
32CP92N1HB*81
32CP92N1HC*81
32DP92N1HA*81
32DP92N1HB*81
32DP92N1HD*81
32DP92N1HE*81
32EP92N1HF*81
32EP92N1HG*81
32FP92N1HH*81
32FP92N1HJ*81
32GP92N1HK*81
32HP92N1HM*81
32HP92N1HN*81
32IP92N1HP*81
32JP92N1HR*81

 Dual

voltage coils not available in modified starters.
conduit hubs and conversion instructions, see
page 8/88.

 For

Product Category: NEMA

8/43

Heavy Duty Contactors

3-Phase, Class 40
Selection

Ordering Information

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/107 open and 8/116 enclosed.
Wiring Diagrams see page 8/142.
Replacement Parts see page 8/157.

䊳

䊳
䊳
䊳
䊳
䊳

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure
Open Type

NEMA 1

NEMA 4/4X
Stainless

General Purpose

Catalog
Number

1 1⁄2
3
7 1⁄2
10
10
15
25
30
40
75
150
—
—

40BP32A*
40CP32A*
40DP32A*
40EP32A*
40FP32A*
40GP32A*
40HP32A*
40IP32A*
40JG32A*
40LP32A*
40MP32A*
40NH32A*
40PH32A*

2
5
10
15
25
30
50
75
100
200
400
600
900

2
5
10
15
25
30
50
75
100
200
400
600
900

9
18
27
40
45
60
90
115
135
270
540
810
1215

00
0
1
—
2
—
3
—
4
5
6
7
8

—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—

NEMA 12
NEMA 3/3R

NEMA 7 & 9
NEMA 3 & 4

Watertight, Dust-tight Watertight, Dust-tight Div1 and Div 2
Industrial Use
Corrosion Resistant
Corrosion Resistant
Class I Groups C & D Weatherproof
304 Stainless Steel
Class II Groups E,F&G
Class III
Bolted Enclosures
Indoor/Outdoor Use

Contactor
200
230
460
575 Amp
NEMA Half
Volts Volts Volts Volts Rating Size
Size

1 1⁄2
3
7 1⁄2
10
15
20
30
40
50
100
200
300
450

NEMA 4X
Fiberglass

List
Catalog
Price $ Number

List
Price $

40BP32B*
40CP32B*
40DP32B*
40EP32B*
40FP32B*
40GP32B*
40HP32B*
40IP32B*
40JG32B*
40LP32B*
40MP32B*
40NH32B*
40PH32B*

Catalog
Number

List
Catalog
Price $ Number

Use Size 0 —
40CP32W*
40DP32W*
40EP32W*
40FP32W*
40GP32W*
40HP32W*
40IP32W*
40JG32W*
40LP32E*
40MP32E*
40NH32E*
40PH32E*

List
Catalog
Price $ Number

Use Size 0
40CP32F*
40DP32F*
40EP32F*
40FP32F*
40GP32F*
40HP32F*
40IP32F*
40JG32F*
—
—
—
—

—

—
—
—
—

List
Catalog
Price $ Number

Use Size 0
40CP32H*
40DP32H*
40EP32H*
40FP32H*
40GP32H*
40HP32H*
40IP32H*
40JG32H*
40LP32H*
—
—
—

—

—
—
—

List
Price $

Use Size 0 —
40CP320*
40DP320*
40EP320*
40FP320*
40GP320*
40HP320*
40IP320*
40JG320*
40LP320*
40MP320*
40NH320*
40PH320*

Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure

200
Volts

230
Volts

1 1⁄2
3
7 1⁄2
10
10
15
25
30
40

1 1⁄2
3
7 1⁄2
10
15
20
30
40
50

460
Volts

575
Volts

2
5
10
15
25
30
50
75
100

2
5
10
15
25
30
50
75
100

Contactor
Amp
NEMA Half
Range
Size
Size

9
18
27
40
45
60
90
115
135

00
0
1
—
2
—
3
—
4

—
—
—
13/4
—
21/2
—
31/2
—

Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.



Dual voltage coils not available in size 5-8 starters.
For conduit hubs and conversion instructions, see
page 8/88.

NEMA 1

NEMA 4/4X Stainless

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Catalog Number

List Price $

40BP82B*
40CP82B*
40DP82B*
40EP82B*
40FP82B*
40GP82B*
40HP82B*
40IP82B*
40JG82B*

Catalog Number

Use Size 0
40CP82W*
40DP82W*
40EP82W*
40FP82W*
40GP82W*
40HP82W*
40IP82W*
40JG82W*

 Enclosure is NEMA
 Only available

Type 4 (painted steel).

F coil 100-250V AC 50/60Hz, or DC
H coil 150-500V AC 50/60Hz, or DC
 Only available
F coil100-250V AC 50/60Hz, or DC

NEMA 7 & 9
NEMA 3 & 4

NEMA 12
NEMA 3/3R

Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

Industrial Use
Weatherproof

List Price $ Catalog Number

—

Use Size 0
40CP82H*
40DP82H*
40EP82H*
40FP82H*
40GP82H*
40HP82H*
40IP82H*
40JG82H*

Product Category: NEMA

—



Use Size 0
40CP820*
40DP820*
40EP820*
40FP820*
40GP820*
40HP820*
40IP820*
40JG820*

—

Standard Auxiliary Contacts
Type

All FVNR
Starters &
Contactors

 Lugs

8/44

List Price $ Catalog Number List Price $

Size (3rd Character)

Configuration

B Thru E

1N.O.

Internal / External
Internal

F Thru J

1N.O.

External

L Thru M

2N.O., 2N.C.

External

N Thru P

1N.O., 1N.C.

External

are not included, refer to page 8/86.

Siemens Industry, Inc.
Industrial Controls Catalog

Heavy Duty Contactors

Single Phase, 4-Pole & Vacuum, Class 40
Selection
Ordering Information

Coil Table

Replace the (*) with a letter from the coil table.
Dual voltage coils are wired on high voltage unless
specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/107 open and 8/116
enclosed.
Wiring Diagrams see page 8/142.
Replacement Parts see page 8/157.

䊳

䊳
䊳
䊳

䊳
䊳

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Open Type & Standard Width Enclosure, Single Phase, 2-Pole 
Max Hp

Enclosure
Open Type

NEMA 1
General Purposes

208/

115
230
Volts Volts
1

⁄3
1
2
3
3
5
7 1⁄3
—
—

1
2
3
5
7 1⁄2
10
15
—
—

NEMA 4/4X
Stainless

NEMA 4X
Fiberglass

NEMA 7 & 9
NEMA 3 & 4

NEMA 12
NEMA 3/3R 

Watertight, Dust-tight
Corrosion Resistant

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosure
Indoor/Outdoor Use

Industrial Use
Weatherproof

Contactor
Amp
NEMA
Rating Size

Half
Size

Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No

9
18
27
35
45
60
90
115
135

—
—
—
—
—
21⁄2
—
31⁄2
—

40BP12A*
40CP12A*
40DP12A*
40EP12A*
40FP12A*
40GP12A*
40HP12A*
40IP12A*
40JG12A*

00
0
1
1P
2
—
3
—
4

40BP12B*
40CP12B*
40DP12B*
40EP12B*
40FP12B*
40GP12B*
40HP12B*
40IP12B*
40JG12B*

Use Size 0
40CP12W*
40DP12W*
40EP12W*
40FP12W*
40GP12W*
40HP12W*
40IP12W*
40JG12W*

—

List Price $

Catalog No

—

Use Size 0
40CP12H*
40DP12H*
40EP12H*
40FP12H*
40GP12H*
40HP12H*
40IP12H*
40JG12H*

Use Size 0
40CP12F*
40DP12F*
40EP12F*
40FP12F*
40GP12F*
40HP12F*
40IP12F*
40JG12F*

List Price $ Catalog No List Price $

—

Use Size 0
40CP120*
40DP120*
40EP120*
40FP120*
40GP120*
40HP120*
40IP120*
40JG120*

—

Open Type & Standard Width Enclosure, 4-Pole
Max Hp

Enclosure
Open Type

NEMA 1
General Purpose

NEMA 4/4X
Stainless 

NEMA 4X
Fiberglass

NEMA 7 & 9
NEMA 3 & 4

NEMA 12
NEMA 3/3R 

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight, Dust-tight
Corrosion Resistant

Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosure
Indoor/Outdoor Use

Industrial Use
Weatherproof

Contactor
200 230 460
575 Amp NEMA Half
Volts Volts Volts Volts Rating Size
Size Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $
1
⁄3
2
3
5

1 1⁄2
3
7 1⁄2
10

2
5
10
15

2
5
10
15

9
18
27
40

00
0
1
—

—
—
—
13⁄4

40BP22A*
40CP22A*
40DP22A*
40EP22A*

40BP22B*
40CP22B*
40DP22B*
40EP22B*

Use Size 0
40CP22W*
40DP22W*
40EP22W*

—

Use Size 0
40CP22F*
40DP22F*
40EP22F*

—

Use Size 0
40CP22H*
40DP22H*
40EP22H*

—

Use Size 0
40CP220*
40DP220*
40EP220*

—

Vacuum Contactors, 3-Phase, 3-Pole 
Max Hp
200V

230V

460V

575V

40
75
150

50
100
200

100
200
400

100
200
400

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.
 Dual

voltage coils not available for vacuum contactors.
Refer to Page 8/95 for a complete list of available coil
voltages.

Siemens Industry, Inc.
Industrial Controls Catalog

 For

Contactor
Amp
Rating
135
270
540

conduit hubs and conversion instructions, see page
8/88.
order single phase contactor in an extra wide enclosure, order the enclosure kit from Page 16-91 and the
open style contactor as separate items.

 To

Product Category: NEMA

NEMA
Size
4
5
6

Open Type
Catalog Number

List Price $

40JV32A*
40LV32A*
40MV32A*

 Coils

D, F, or G will be wired for incoming voltage.
J coil will be wired for separate source. Coils E, H,
and L do not apply to single phase starters.
 1 NO Auxiliary.

8/45

Reversing Heavy Duty Contactors

Class 43
Selection

Ordering Information
䊳

䊳
䊳
䊳
䊳
䊳

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/108 open and 8/121 enclosed.
Wiring Diagrams see page 8/142.
Replacement Parts see page 8/157.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

Letter
J
F
A
D
G
L
C
H
E

For other voltages and frequencies,
see Factory Modifications page 8/95.

Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp

Enclosure
Open Type

NEMA 1
General Purpose

Contactor
200 230 460 575 Amp NEMA Half Catalog
Volts Volts Volts Volts Rating Size Size Number
1

⁄2
3
7 1⁄2
10
10
15
25
30
40
75
100
—
—

1

⁄2
3
7 1⁄2
10
15
20
30
40
50
100
200
300
450

2
5
10
15
25
30
50
75
100
200
400
600
900

2
5
10
15
25
30
50
75
100
200
400
600
900

9
18
27
40
45
60
90
115
135
270
540
810
1215

00
0
1
—
2
—
3
—
4
5
6
7
8

—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—

List
Catalog
Price $ Number

43BP32A*
43CP32A*
43DP32A*
43EP32A*
43FP32A*
43GP32A*
43HP32A*
43IP32A*
43JG32A*
43LP32A*
43MP32A*
43NH32A*
43PH32A*

NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight NEMA 3 & 4

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

List
Catalog
Price $ Number

43BP32B*
43CP32B*
43DP32B*
43EP32B*
43FP32B*
43GP32B*
43HP32B*
43IP32B*
43JG32B*
43LP32B*
43MP32B*
43NH32B*
—

—

List
Price $

Use Size 0
43CP32W*
43DP32W*
43EP32W*
43FP32W*
43GP32W*
43HP32W*
43IP32W*
43JG32W*
43LP32E*
43MP32E* 
43NH32E* 
—

—

—

Corrosion Resistant

Catalog
Number

Use Size 0
43CP32F*
43DP32F*
43EP32F*
43FP32F*
43GP32F*
43HP32F*
43IP32F*
43JG32F*
—
—
—
—

List
Catalog
Price $ Number

—

—
—
—
—

NEMA 12 
NEMA 3/3R

Div 1 and Div 2
Industrial Use
Class I Groups C & D
Weatherproof
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

List
Price $

Use Size 0
43CP32H*
43DP32H*
43EP32H*
43FP32H*
43GP32H*
43HP32H*
43IP32H*
43JG32H*
—
—
—
—

—

—
—
—
—

Catalog
Number

Use Size 0
43CP320*
43DP320*
43EP320*
43FP320*
43GP320*
43HP320*
43IP320*
43JG320*
43LP320*
43MP320*
43NH320*
—

List
Price $

—

—

Open Type & Standard Width Enclosure, Single Phase, 3-Wire, 2-Pole
Max Hp

Enclosure
Open Type

Cont208/ actor
115 230 Amp NEMA
Volts Volts Rating Size Catalog No

1 1⁄3
1
2
3

1
2
3
5

9
18
27
35

00
0
1
1P

43BP12A*
43CP12A*
43DP12A*
43EP12A*

NEMA 1

NEMA 4/4X Stainless  NEMA 4X Fiberglass

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

List Price $ Catalog No List Price $ Catalog No

43BP12B*
43CP12B*
43DP12B*
43EP12B*

Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.
 Dual voltage coils not available in size 5–8 starters.
 For conduit hubs and conversion instructions, see

page 8/88.

8/46

Use Size 0
43CP12W*
43DP12W*
43EP12W*

List Price $

—

Watertight, Dust-tight
Corrosion Resistant

Catalog No

List Price $

Use Size 0
43CP12F*
43DP12F*
43EP12F*

 Enclosure
 Coils D, F,

is NEMA Type 4 (painted steel).
or G will be wired for incoming voltage. J
coil will be wired for separate source. Coils E, H, and
L do not apply to single phase starters.
 Only available
F coil 100-250V AC 50/60Hz, or DC
H coil 150-500V AC 50/60Hz, or DC

Product Category: NEMA

—

NEMA 7 & 9
NEMA 3 & 4

NEMA 12 
NEMA 3/3R

Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use

Industrial Use
Weatherproof

Catalog No

List Price $

Use Size 0
43CP12H*
43DP12H*
43EP12H*

—

Catalog No

Use Size 0
43CP120*
43DP120*
43EP120*

List Price $

—

 Only

available
F coil 100-250V AC 50/60Hz, or DC
contacts
43B-43E 4th pole built-in
43F-43J 2 NO & 2 NC

 Auxiliary

Siemens Industry, Inc.
Industrial Controls Catalog

Heavy Duty Control

Catalog Numbering System
General

Class

48 — Overload

No. of Poles

Size

A — Frame A
B — Frame B

Model

3 — 3 Phase
1 — Single Phase

T — ESP200

Trip Curve

00 — Class 5, 10, 20 or 30 Selectable

Current Range

A
B
C
D
E
F
G
H
J
K
L
M
N

—
—
—
—
—
—
—
—
—
—
—
—
—

0.25–1
Reset
0.75–3.4
3–12
S — Selectable (Man/Auto)
5.5–22
10–40
13–52
25–100
50–200
100–300 (3.33-10 current range with 300:5 CT and 1 loop with frame A1 (3-12A)-device)
133–400 (3.33-10 current range with 400:5 CT and 1 loop with frame A1 (3-12A)-device)
200–600 (3.33-10 current range with 600:5 CT and 1 loop with frame A1 (3-12A)-device)
250–750 (3.33-10 current range with 750:5 CT and 1 loop with frame A1 (3-12A)-device)
400–1200 (3.33-10.17 currant range with 1200:5 CT and 1 loop with frame A1 (3-12A)-device)

Trip Curve

Class
Model

958 — Overload
Amp Range

A — 958

B — ESP200

Type

S — Selectable (Man/Auto)

E — 10–40
G — 25–100
H — 50–200

No. of Poles

3 — 3 phase

Trip Curve

Class

958L

Model

— Overload
Amp Range

D
E
F
G
H

 Ranges

—
—
—
—
—

5.5–22
10–40
13–52
25–100
50–200

A — 958L

B — ESP200

Type

S — Selectable (Man/Auto)
No. of Poles

3 — 3 phase

available in Single or 3-phase.

Siemens Industry, Inc.
Industrial Controls Catalog

8/47

Overload Relays

Solid State ESP200, Class 48, 958 and 958L
General

Features

Benefits

▪ Trip Classes - 5, 10, 20, or 30 Selectable by DIP-switches

▪ Field changeable reduces time and inventory. Suitable for
light, normal and heavy starting conditions

▪ Phase Loss Protection - Trips in less than 3 Seconds

▪ Protects motor burn out and minimizes motor heating up

▪ Phase Unbalance - Trips based on Trip Class selected

▪ Minimizes temperature rise of the motor on a asymmetrical
three-phase-system

▪ Ground Fault - Trips 60% of Motor Current

▪ Provides optimum system protection of motors against
high-resistance short-circuits or ground faults due to moisture,
condensation, damage of insulation or any other reason

▪ Trip Indicator - Visible

▪ Save time, faster to identify overload Trip

▪ Ambient Insensitive

▪ Prevents nuisance tripping

▪ No Heaters Required

▪ Saves cost and eliminates time for installation of heaters

▪ Self-Powered - No outside source required

▪ Reduce cost for external power supply

▪ FLA dial with wide Adjustment - 4:1 ratio

▪ Provides wide range, reduces inventory

▪ Self Protected in short circuit condition (when used with
proper fuses or motor starter protector)

▪ Unlike bimetal overloads, this eliminates replacement of the
overload heaters after short circuit

▪ Test Button - Tests Electronics

▪ Tests the complete electronic functions including the trip
mechanism. Increases up time

▪ Thermal Memory

▪ Prevents re-starting motor when it is still hot

▪ Conformally coated circuit board

▪ Resists against environmental conditions

▪ 1 NO and 1NC Contacts Standard. B600, R300

▪ Makes it easier for user to wire local contacts

▪ Operating Temperature: -25 °C - 65 °C

▪ Wide operating temperature range prevents nuisance tripping
with temperature changes

▪ Repeat Accuracy <1%.

▪ For more precise settings and reduced nuisance tripping

▪ Removable Terminal Block

▪ Terminal Block can be removed without removing wires.
Saves time for replacements

▪ Automatic reset

▪ Auto. Reset is 3 minutes after tripping, allowing motor to
cool down before re-start. If Manual Reset is selected,
overload can be reset immediately

▪ Remote reset

▪ As an alternative to the mechanical RESET options, an
electrical remote RESET can be used by applying 24 V DC
to terminals A3 and A4

▪ DIN Rail Mounted

▪ Reduces installation time

▪ Touch - Safe Terminals

▪ Protects against accidental touching of live circuits

▪ UL listed CSA certified

▪ Third party approval standard

8/48

Siemens Industry, Inc.
Industrial Controls Catalog

Overload Relays

Solid State ESP200, Class 48, 958, 958L and Bimetal
General

ESP200 Solid State Overload

Applications
ESP200 Solid State Overloads
Designed for a wide variety of applications. The field selectable Trip Class 5,
10, 20 or 30 can easily be set by 2 DIP
switches. This eliminates the guess
factor of an application requirements
and provides reduced inventory for
multiple applications. The inherent
benefits of the ESP200 ultimately
results in cost savings for the user.
ESP200 has a 4:1 current adjustment
range with a fine adjustment dial
labeled in full load amps. The heaterless overload minimizes the heat
trapped in the enclosures, reduces cost
for ventilation or cooling. Easily accessible Reset button, provides visible and
audible indications to ensure the tripped
overload is ready to re-start.
Designed to replace thermal, or ESP100
overload relays for any application. It
has the same dimensions and footprint
of the ESP100 overload relays. It can
be directly coupled to the contactors
or remotely mounted. In addition to
the NEMA contactor applications, it
also can be used with other types of
controllers for applications requiring DP
or IEC contactors. As a retrofit for other
brands, it is used with a plate available
for retrofitting competitive products.

958 or 958L Solid State Overload

958 ESP200 Special Use Solid State
Overloads
This overload is specifically designed for
special applications, to provide excellent
protection of hermetically sealed and
artificially cooled motors that require
ambient insensitive and quick trip
response times. Combined with a series
lockout relay, it provides unsurpassed
protection for hermetically sealed
compressor motors in air conditioning
applications. The combination of high trip
speed, current adjustment, and ease of
installation makes it suitable for these
applications. The trip curves are
customized to provide proper overload
protection for these loads without
causing nuisance tripping.
It has selectable manual or automatic
reset mode, and provides ground fault
selection to protect equipment from
damage in case of a fault.

958L ESP200 Oil Field Solid State
Overloads
Specifically designed for the oil market
and the cycling loads experienced with
these types of pumping applications.
These overload relays provide protection
for standard motors, oil well pump
motors, multi-torque connections, and
ultra-high slip motors.
Rotors can be damaged in less than 15
seconds during motor stall conditions
if electrical power is not removed. To
prevent damage during motor stall, the
958L solid state overload removes the
power in 7 seconds at 250% lock rotor
current. Therefore, the motor casing
and the rotor will be protected from
being damage saving the user money
and time.

Siemens Industry, Inc.
Industrial Controls Catalog

Ambient Compensated Bimetal
Single Phase and Three Phase

▪ Ambient Compensated Bimetal
Overloads
—Automatic or manual reset adjustment
—A manual test button is provided to
test the operation of the 3-pole
overload relay control contacts
—앐15% nominal trip current adjustment
—Accept either standard Class 20 or
Quick Trip (NEMA Class 10) heater
elements without any other
changes or adjustments
—Available with a normally open contact
for an alarm circuit (SPDT) up to 60A
—Compensated bimetal overload relays
provide a constant trip time in ambient temperatures from –20°F to
ѿ170°F for a given heater rating
▪ UL Listed File #E22655 or Component
Recognized
▪ CSA Certified File #LR6535
Ambient Compensated Bimetal
Overloads
These thermal type overload relays are
used to protect motors from excessive
heat resulting from sustained motor
overloads, rapid motor cycling and
stalled rotor conditions. Although these
devices function based on thermal
principles they are designed to
compensate for the ambient air
temperature surrounding the overload.
This helps prevent the occurrence of nuisance tripping when there are high surrounding ambient temperatures.
The percentage of overload determines
the length of time required to open the
circuit.

8/49

Overload Relays

Solid State Class 48, ESP200 and 3RB20
Selection
Ordering Information
䊳
䊳
䊳

䊳

For CT’s see Accessories page 8/51.
Dimensions see page 8/109.
To retrofit or direct mount to a contactor, order 49ASMP1, 2, or 3 separately. See
Retrofit Plates below.
For remote mounting of frame size A order 49ASMS1 terminals separately, see page 8/86.

3-Phase, 48ATC3S00

Solid State—Class 48
Current Adjustment Range

Phase

Frame Size

Catalog Number

MRPD/MLFB

0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200
100–300
133–400
200–600
250–750
400–1220
0.25–1
0.75–3.4
3–12
5.5–22

3
3
3
3
3
3
3
3
3
3
3
3
3
1
1
1
1

"A"
"A"
"A1"
"A1"
"A1"
"B"
"B"
"B"
"A1" 
"A1" 	
"A1" 
"A1" 
"A1" 
"A"
"A"
"A1"
"A1"

48ATA3S00
48ATB3S00
48ATC3S00
48ATD3S00
48ATE3S00
48BTF3S00
48BTG3S00
48BTH3S00
48ATJ3S00
48ATK3S00
48ATL3S00
48ATM3S00
48ATN3S00
48ATA1S00
48ATB1S00
48ATC1S00
48ATD1S00

3UB81134AB2
3UB81134BB2
3UB81234CW2
3UB81234DW2
3UB81234EW2
3UB81334FW2
3UB81334GW2
3UB81334HW2
3UB81234JW2
3UB81234KW2
3UB81234LW2
3UB81234MW2
3UB81234NW2
3UB88134AB2
3UB88134BB2
3UB88234CW2
3UB88234DW2

List Price $

Solid State—3RB206, 3-Phase, Manual/Auto Reset
For Contactor Size

Setting Range Amps

Class 10
Catalog Number

5
6

55 - 250
160 - 630

3RB2066-1GC2
3RB2066-1MC2

List Price $

Class 20
Catalog Number

List Price $

3RB2066-2GC2
3RB2066-2MC2

Retrofit Plates for Contactors, Class 48
Replacement for Starter Sizes

ESP200 Overload Frame Size

Retrofit Plate Suffix

Plate Kit Separate

Size 00–13⁄4
Size 2, 21⁄2
Size 3, 31⁄2
Size 4

A or A1
B
B
B

1P
2P
3P
4P

49ASMP1
49ASMP2
49ASMP3
49ASMP3

Price Adder $

Ambient Compensated Bimetal—Open Type Class 48 Single Phase, 3-Phase (Panel Mount Only)
Poles

1

3

Amp
Rating

Auxiliary Contacts

25
60
100
180
30
30
60
60
100
180

1 NC
1 NC
1 NC
1 NC
1 NC
1 NO/NC
1 NC
1 NO/NC
3 NC
3 NC

Contact
Rating

5A (B600)
&
5A (P300)
10A (A600)
&
5A (P300)
5A (B600) & 5A (P300)

Catalog Number

48DA18AA4
48GA18AA4
48HA18AA4
48JA18AA4
48DC38AA4
48DC39AA4
48GC38AA4
48GC39AA4
48HA38AA4
48JA38AA4

 To

 Requires

use of 600:5 Current Transformers–3 of

 Requires

97CT008.

97CT009.

 Requires

 Requires

use of 1200:5 Current Transformers–3 of

	 Requires

determine frame size of replacement solid state
overload, refer to retrofit plates table above.
use of 300:5 Current Transformers–3 of
97CT005.
 Product Category: IEC.

8/50

97CT012.
 Overload

List
Price $

use of 750:5 Current Transformers–3 of
use of 400:5 Current Transformers–3 of

97CT006.
has busbar connections.

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Overload Relays

Special Use Solid State Overloads, Class 958 and 958L
Selection
Ordering Information
Current Transformers

Dimensions see page 8/109.

䊳

Rating

Class 958, 958L

Catalog No.

150:5

97CT002

200:5

97CT003

250:5

97CT004

300:5

97CT005

400:5

97CT006

600:5

97CT008

750:5

97CT009

1200:5

97CT012

List Price $

Solid State—Class 958 and 958L
Current Adjustment Range

Phase

Frame Size

Catalog Number

MRPD/MLFB

10–40
25–100
50–200
5.5–22
10–40
13–52
25–100
50–200

3
3
3
3
3
3
3
3

"A1"
"B"
"B"
"A1"
"A1"
"B"
"B"
"B"

958EB3SA
958GB3SA
958HB3SA
958LDB3SA
958LEB3SA
958LFB3SA
958LGB3SA
958LHB3SA

3UB85235EW2
3UB85335GW2
3UB85335HW2
3UB85236DW2
3UB85236EW2
3UB85336FW2
3UB85336GW2
3UB85336HW2

Time - Current - Characteristics
CLASS 958, 958L

Time - Current - Characteristics
CLASS 48

List Price $

Trip - curve depending on unbalance
CLASS 20
1000

1000

1000

Trip time in seconds

Trip time in seconds

Trip time in seconds

500

100

50

phase unbalance = 0%, CLASS 20
phase unbalance = 20%, CLASS 20
phase unbalance = 50%, CLASS 20
phase unbalance = 80%, CLASS 20
phase unbalance = 100%, CLASS 20

500

500

100

100

50

50

CLASS 30 - cold start

CLASS 20 - cold start

10

10

10
CLASS 958L

CLASS 10 - cold start

5

5

5
CLASS 5 - cold start

CLASS 5 - warm start
CLASS 958

1

1

0.6

1

1.5

2
multiple of full load amp (FLA)

5

multiple of full load amp (FLA)

10

0.6

1

1.5

2

5

10

1

multiple of full load amp (FLA)

multiple of full load amp (FLA)

0.6

1

1.5

2

10

5

multiple of full load amp (FLA)

multiple of full load amp (FLA)

 Temperature

rating 앥25° to 쎵60°C.

Siemens Industry, Inc.
Industrial Controls Catalog

Product Category: NEMA

8/51

Duplex Heavy Duty Controllers
General

Class 83

Class 84

Features
▪ Heavy Duty NEMA Starters
▪ Solid State or Thermal Overload
Relays
▪ Fusible or MCP
▪ Heavy Duty Disconnect Handle
▪ Flexibility with Field Modifications
▪ Alternator Transfer on De-energization
▪ UL Listed for Outdoor Use and
Service Equipment
▪ UL Listed file #E14900 (class 83); file
#E185287 (class 84)
▪ CSA certified file #LR 6535 (class 83
& 84)

Application
Duplex pump controls are designed to
perform one or both of two distinct
functions: duplexing and alternation. The
duplexing function provides capacity for
system peaking or above normal demand
without having the full motor capacity
spinning at all times. It also provides
standby capacity for use when one of
the motors or pumps is disabled. The
duplexing function is also referred to as
lead/lag or main/standby. When two
pumps or compressors are controlled by
a duplex controller, they are started in
sequence as necessary to attain preset
values of pressure, flow or liquid level.

8/52

Two field devices such as pressure
switches or float switches provide
electrical signals to the duplex controller.
One remote device is set to initiate the
starting of the lead motor. This motor is
rated to handle normal system demand.
The second motor is usually the same
rating and is referred to as the lag motor.
It is only energized when the system
demand is greater than the capacity of
the lead motor. The lag motor is started
when the second remote device is
signalling for more output than the
lead motor can produce.
The alternation function reverses the lead
and lag mode for the two motors in a
duplex system. Upon alternation the first
motor as described above becomes the
lag motor and the second motor
assumes the lead function. The
alternation is usually programmed to
occur at any time both pumps come to
rest. The alternation function equalizes
wear on the two machines and extends
the life of seals and bearings.
Enclosure Types
Duplex controllers are available in
NEMA 1, 12/3/3R, 4 (painted) and
4/4X (stainless) enclosures.
Enclosures protect personnel from
contact with live parts and depending
upon the construction, protect the
control in varying degrees from physical
damage and harmful atmospheres. All
enclosures are supplied with corrosion
resistant finishes.
Heavy Duty Starters
These Duplex controllers use the same
starters described in the heavy duty
starter section of this catalog.
Siemens Type ETI Circuit Breaker
The ETI circuit breaker is a device
designed specifically for application
in motor circuits. The ETI is a magnetic
only protective device designed to
provide protection against short
circuit current.
The instantaneous-only type ETI circuit
breaker employs adjustable magnetic
trip settings to allow broader application
ranges and a higher degree of motor
short circuit protection.

Features
Two control transformers may be
provided for low voltage control to
safeguard personnel from high voltage.
One transformer is required for each
starter to provide independent control
circuits.
A Hand-Off-Auto selector switch for each
starter may be mounted in the enclosure
door or furnished separately for remote
control. Test push buttons or pilot lights
may also be installed on the enclosure.
Solid-state or Ambient Compensated
Bimetal Overload Relays are supplied as
standard.
Heavy Duty Disconnect Switches
The disconnect switch that goes the
distance in durability, performance and
reliability has the following advantages:
▪ Visible blades for the highest level
of safety
▪ Double break switching action to
reduce arcing, increase lifetime and
eliminate the “electric hinge”
▪ More rugged positive action switch
▪ Oversized lugs are standard
▪ Line side shield to help guard
personnel from contact with live parts
▪ Higher horsepower rating for
design E high efficiency motors
▪ UL listed for IIsco, Burndy and T&B
crimp type lugs
▪ The 200A switch accepts up to 300
MCM versus 250 MCM wire size
Its rugged construction - with a high
fault withstand rating of 100kA at 600
VAC when fused with class R rated
fuses - meets the most stringent
industry standards set forth by the
automotive, petro-chemical, and pulp
and paper industries. UL recognized and
CSA certified, our disconnect switches
are available either non-fusible or fusible
with class R and class J fuse clips.

Siemens Industry, Inc.
Industrial Controls Catalog

Duplex Heavy Duty Controllers

Non-Combination, Class 83
Selection










Ordering Information

Coil Table

Standard coil voltage supplied will be 120V, separate control.
For non-alternator styles (see factory modifications) change
the 9th character using the coil table.
Heater elements for bimetal overloads see page 8/150 (6-Required).
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/127.
Wiring Diagrams see page 8/143.
Replacement Parts see page 8/157.

60Hz Voltage

Letter


24 Separate Control
120 Separate Control
200–208
220–240
277
440–480
550–600

J
F
D
G
L
H
E

Non-Combination (with Solid-State Overload)
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

200
Volts

230
Volts

460
Volts

575
Volts

NEMA
Size

Half
Size

Amp
Range

Frame
Size

Catalog
Number

List
Price $

NEMA 4/4X Stainless

NEMA 4 Painted

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight

Catalog
Number

Catalog
Number

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Price $

List
Price $

Catalog
Number

⁄6

1

⁄6

1

⁄3

1

⁄2

0

—

0.25–1

A

83CUA92BF

83CUA92WF

83CUA92EF

83CUA920F

1

⁄2

3

⁄4

11⁄2

2

0

—

0.75–3.4

A

83CUB92BF

83CUB92WF

83CUB92EF

83CUB920F

2

2

5

5

0

—

3–12

A1

83CUC92BF

83CUC92WF

83CUC92EF

83CUC920F

3

3

—

—

0

—

5.5–22

A1

83CUD92BF

83CUD92WF

83CUD92EF

83CUD920F

⁄6

1

1

⁄2

1

⁄6

1

⁄3

1

⁄2

1

—

0.25–1

A

83DUA92BF

83DUA92WF

83DUA92EF

83DUA920F

3

⁄4

11⁄2

2

1

—

0.75–3.4

A

83DUB92BF

83DUB92WF

83DUB92EF

83DUB920F

2

2

5

5

1

—

3–12

A1

83DUC92BF

83DUC92WF

83DUC92EF

83DUC920F

3

3

10

10

1

—

5.5–22

A1

83DUD92BF

83DUD92WF

83DUD92EF

83DUD920F

71⁄2

71⁄2

—

—

1

—

10–40

A1

83DUE92BF

83DUE92WF

83DUE92EF

83DUE920F

10

10

15

15

—

13⁄4

10–40

A1

83EUE92BF

83EUE92WF

83EUE92EF

83EUE920F

10

15

25

25

2

—

13–52

B

83FUF92BF

83FUF92WF

83FUF92EF

83FUF920F

15

20

30

30

—

21⁄2

25–100

B

83GUG92BF

83GUG92WF

83GUG92EF

83GUG920F

25

30

50

50

3

—

25–100

B

83HUG92BF

83HUG92WF

83HUG92EF

83HUG920F

30

40

75

75

—

31⁄2

50–200

B

83IUH92BF

83IUH92WF

83IUH92EF

83IUH920F

40

50

100

100

4

—

50–200

B

83JUH92BF

83JUH92WF

83JUH92EF

83JUH920F

1

List
Price $

Non-Combination (with Ambient Compensated Bimetal Overload)
Max Hp

Enclosure

200
Volts

230
Volts

3
71⁄2
10
10
15
25
30
40

3
71⁄2
10
15
20
30
40
50

460
Volts

5
10
15
25
30
50
75
100

575
Volts

5
10
15
25
30
50
75
100

NEMA Half
Size
Size

0
1

—
—

—

13⁄4

2

—

—

21⁄2

3

—

—

31⁄2

4

—

NEMA 1

NEMA 4/4X Stainless

NEMA 4 Painted

NEMA 12/3R

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight
Dust-tight

Industrial Use
Weatherproof

Catalog Number

Catalog Number

Catalog Number

Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.

Siemens Industry, Inc.
Industrial Controls Catalog

List Price $

83CP92BF81
83DP92BF81
83EP92BF81
83FP92BF81
83GP92BF81
83HP92BF81
83IP92BF81
83JP92BF81

List Price $

83CP92WF81
83DP92WF81
83EP92WF81
83FP92WF81
83GP92WF81
83HP92WF81
83IP920W81
83JP92WF81

 NEMA

12 is field convertible to NEMA 3/3R. For conduit
hubs and conversion instructions, see page 8/88.
 Not available on standard alternator style ('92' in the
catalog number).

Product Category: NEMA

List Price $

83CP92EF81
83DP92EF81
83EP92EF81
83FP92EF81
83GP92EF81
83HP92EF81
83IP92EF81
83JP92EF81

Catalog Number

List Price $

83CP920F81
83DP920F81
83EP920F81
83FP920F81
83GP920F81
83HP920F81
83IP920F81
83JP920F81

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

8/53

Duplex Heavy Duty Controllers

Combination Disconnect [Fusible & Non-Fusible], Class 84
Selection

䊳

䊳
䊳
䊳
䊳
䊳
䊳
䊳

Ordering Information

Coil Table

Standard coil voltage supplied will be 120V, separate control.
For non-alternator styles (see factory modifications) change
the 10th character using the coil table.
Heater elements for bimetal overloads see page 8/150 (6-Required).
For factory installed fusible disconnect, see page 8/96.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/127.
Wiring Diagrams see page 8/143.
Replacement Parts see page 8/157.

60Hz Voltage

Letter

24 Separate Control
120 Separate Control
200–208
220–240
277
440–480
550–600

J
F
D
G
L
H
E

Two Disconnect Switches with Solid-State Overload
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

200 230 460 575 NEMA
Volts Volts Volts Volts Size

Half Amp
Size Range

Disc.
Frame Amp
Catalog
Size
Range Number

List
Price $

NEMA 4/4X Stainless

NEMA 4 Painted

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight

Catalog
Number

Catalog
Number

List
Price $

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Price $

Catalog
Number

⁄6

1

⁄6

1

⁄3

1

⁄2

0

—

0.25–1

A

30

84CUA92BDF

84CUA92WDF

84CUA92EDF

84CUA920DF

1

⁄2

3

⁄4

11⁄2

2

0

—

0.75–3.4

A

30

84CUB92BDF

84CUB92WDF

84CUB92EDF

84CUB920DF

2

2

5

5

0

—

3–12

A1

30

84CUC92BDF

84CUC92WDF

84CUC92EDF

84CUC920DF

3

3

—

—

0

—

5.5–22

A1

30

84CUD92BDF

84CUD92WDF

84CUD92EDF

84CUD920DF

⁄6

1

1

⁄2

1

⁄6

1

⁄3

1

⁄2

1

—

0.25–1

A

30

84DUA92BDF

84DUA92WDF

84DUA92EDF

84DUA920DF

3

⁄4

11⁄2

2

1

—

0.75–3.4

A

30

84DUB92BDF

84DUB92WDF

84DUB92EDF

84DUB920DF

2

2

5

5

1

—

3–12

A1

30

84DUC92BDF

84DUC92WDF

84DUC92EDF

84DUC920DF

3

3

10

10

1

—

5.5–22

A1

30

84DUD92BDF

84DUD92WDF

84DUD92EDF

84DUD920DF

71⁄2

71⁄2

—

—

1

—

10–40

A1

30

84DUE92BDF

84DUE92WDF

84DUE92EDF

84DUE920DF

10

10

15

15

—

13⁄4

10–40

A1

60

84EUE92BDF

84EUE92WDF

84EUE92EDF

84EUE920DF

10

15

25

25

2

—

13–52

B

60

84FUF92BDF

84FUF92WDF

84FUF92EDF

84FUF920DF

15

20

30

30

—

21⁄2

25–100

B

100

84GUG92BDF

84GUG92WDF

84GUG92EDF

84GUG920DF

20

25

50

50

3

—

25–100

B

100

84HUG92BDF

84HUG92WDF

84HUG92EDF

84HUG920DF

30

40

75

75

—

31⁄2

50–200

B

200

84IUH92BDF

84IUH92WDF

84IUH92EDF

84IUH920DF

40

50

100

100

4

—

50–200

B

200

84JUH92BDF

84JUH92WDF

84JUH92EDF

84JUH920DF

1

List
Price $

Two Disconnect Switches with Ambient Compensated Bimetal Overload
Max Hp

Enclosure

200
Volts

230
Volts

3
71⁄2
10
10
15
20
30
40

3
71⁄2
10
15
20
25
40
50

460
Volts

5
10
15
25
30
50
75
100

575
Volts

5
10
15
25
30
50
75
100

NEMA Half
Size
Size

0
1

—
—

—

13⁄4

2

—

—

21⁄2

3

—

—

31⁄2

4

—

NEMA 4/4X Stainless

NEMA 4 Painted

NEMA 12/3R

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight
Dust-tight

Industrial Use
Weatherproof

Catalog Number

Catalog Number

Disc
Amp
Range Catalog Number

30
30
60
60
100
100
200
200

Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.

8/54

NEMA 1

List Price $

List Price $

List Price $

Catalog Number

84CP92BDF81
84DP92BDF81
84EP92BDF81
84FP92BDF81

84CP92WDF81
84DP92WDF81
84EP92WDF81
84FP92WDF81

84CP92EDF81
84DP92EDF81
84EP92EDF81
84FP92EDF81

84CP920DF81
84DP920DF81
84EP920DF81
84FP920DF81

84GP92BDF81
84HP92BDF81
84IP92BDF81
84JP92BDF81

84GP92WDF81
84HP92WDF81
84IP92WDF81
84JP92WDF81

84GP92EDF81
84HP92EDF81
84IP92EDF81
84JP92EDF81

84GP920DF81
84HP920DF81
84IP920DF81
84JP920DF81

 NEMA

12 is field convertible to NEMA 3/3R. For conduit
hubs and conversion instructions, see page 8/88.
 Not available on standard alternator style
('92' in the catalog number).

Product Category: NEMA

List Price $

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

Siemens Industry, Inc.
Industrial Controls Catalog

Duplex Heavy Duty Controllers

Combination Circuit Breaker, Class 84
Selection

䊳

䊳
䊳
䊳
䊳
䊳
䊳

Ordering Information

Coil Table

Standard coil voltage supplied will be 120V, separate control.
For non-alternator styles (see factory modifications) change
the 10th character using the coil table.
Heater elements for bimetal overloads see page 8/150 (6-Required).
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/127.
Wiring Diagrams see page 8/143.
Replacement Parts see page 8/157.

60Hz Voltage

Letter

24 Separate Control
120 Separate Control
200–208
220–240
277
440–480
550–600

J
F
D
G
L
H
E

2 Motor Circuit Protectors (with Solid-State Overload)
Max Hp

Enclosure
NEMA 1

Overload

General Purpose

200 230 460 575 NEMA Half Amp
Volts Volts Volts Volts Size
Size Range

Motor
Circuit
Frame Interrupter Catalog
Size
ETI
Number

1

⁄6
⁄2
2
3

1

1

3

1

⁄6
⁄2
2
3
71⁄2

1

1

3

List
Price $

NEMA 4/4X Stainless

NEMA 4 Painted

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)

Watertight, Dust-tight

Catalog
Number

Catalog
Number

NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)

List
Price $

List
Price $

Catalog
Number

⁄6
⁄4
2
3

1

⁄3
11⁄2
5
—

1

⁄2
2
5
—

0
0
0
0

—
—
—
—

0.25–1
0.75–3.4
3–12
5.5–22

A
A
A1
A1

3
3
10
25

84CUA92BMF
84CUB92BMF
84CUC92BMF
84CUD92BMF

84CUA92WMF
84CUB92WMF
84CUC92WMF
84CUD92WMF

84CUA92EMF
84CUB92EMF
84CUC92EMF
84CUD92EMF

84CUA920MF
84CUB920MF
84CUC920MF
84CUD920MF

⁄6
⁄4
2
3
71⁄2

1

⁄3
11⁄2
5
10
—

1

⁄2
2
5
10
—

1
1
1
1
1

—
—
—
—
—

0.25–1
0.75–3.4
3–12
5.5–22
10–40

A
A
A1
A1
A1

3
3
10
25
30

84DUA92BMF
84DUB92BMF
84DUC92BMF
84DUD92BMF
84DUE92BMF

84DUA92WMF
84DUB92WMF
84DUC92WMF
84DUD92WMF
84DUE92WMF

84DUA92EMF
84DUB92EMF
84DUC92EMF
84DUD92EMF
84DUE92EMF

84DUA920MF
84DUB920MF
84DUC920MF
84DUD920MF
84DUE920MF

—

—

15

15

—

13⁄4

10–40

A1

40

84EUE92BMF

84EUE92WMF

84EUE92EMF

84EUE920MF

10

15

25

25

2

—

13–52

B

50

84FUF92BMF

84FUF92WMF

84FUF92EMF

84FUF920MF

15

20

30

30

—

21⁄2

25–100

B

100

84GUG92BMF

84GUG92WMF

84GUG92EMF

84GUG920MF

20

25

50

50

3

—

25–100

B

100

84HUG92BMF

84HUG92WMF

84HUG92EMF

84HUG920MF

30

40

75

75

—

31⁄2

50–200

B

125

84IUH92BMF

84IUH92WMF

84IUH92EMF

84IUH920MF

40

50

100

100

4

—

50–200

B

150

84JUH92BMF

84JUH92WMF

84JUH92EMF

84JUH920MF

List
Price $

2 Motor Circuit Protectors (with Ambient Compensated Bimetal Overload)
Max Hp

Enclosure

200 230
460
575
NEMA Half
Volts Volts Volts Volts Size
Size

⁄
2
3
1⁄2
2
3
71⁄2
—
10
—
10
—
15
—
20
30
40
12

⁄

34

2
3
3⁄4
2
3
71⁄2
—
10
—
15
—
20
—
25
40
50

11⁄2
5
—
11⁄2
5
10
—
15
—
15
25
30
—
30
50
75
100

2
5
—
2
5
10
—
15
—
20
25
30
—
40
50
75
100

0
0
0
1
1
1
1

—
—
—
—
—
—
—

—
—

13⁄4
13⁄4

2
2

—
—

—
—

21⁄2
21⁄2

3
3

—
—

—

31⁄2

4

—

Motor
Circuit
Interrupter
ETI

3
10
25
3
10
25
30
40
50
40
50
50
100
50
100
125
150

Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.

Siemens Industry, Inc.
Industrial Controls Catalog

NEMA 1

NEMA 4/4X Stainless

NEMA 4 Painted

NEMA 12/3R

General Purpose

Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel

Watertight
Dust-tight

Industrial Use
Weatherproof

Catalog
Number
84CPB92BMF81
84CPD92BMF81
84CPE92BMF81
84DPB92BMF81
84DPD92BMF81
84DPE92BMF81
84DPF92BMF81
84EPF92BMF81
84EPG92BMF81
84FPF92BMF81
84FPH92BMF81
84GPH92BMF81
84GPJ92BMF81
84HPJ92BMF81
84HPK92BMF81
84IPL92BMF81
84JPM92BMF81

List
Price $

Catalog
Number
84CPB92WMF81
84CPD92WMF81
84CPE92WMF81
84DPB92WMF81
84DPD92WMF81
84DPE92WMF81
84DPF92WMF81
84EPF92WMF81
84EPG92WMF81
84FPF92WMF81
84FPH92WMF81
84GPH92WMF81
84GPJ92WMF81
84HPJ92WMF81
84HPK92WMF81
84IPL92WMF81
84JPM92WMF81

 NEMA


List
Price $

12 is field convertible to NEMA 3/3R. For conduit
hubs and conversion instructions, see page 8/88.
Not available on standard alternator style
('92' in the catalog number).

Product Category: NEMA

Catalog
Number
84CPB92EMF81
84CPD92EMF81
84CPE92EMF81
84DPB92EMF81
84DPD92EMF81
84DPE92EMF81
84DPF92EMF81
84EPF92EMF81
84EPG92EMF81
84FPF92EMF81
84FPH92EMF81
84GPH92EMF81
84GPJ92EMF81
84HPJ92EMF81
84HPK92EMF81
84IPL92EMF81
84JPM92EMF81

List
Price $

Catalog
Number

List
Price $

84CPB920MF81
84CPD920MF81
84CPE920MF81
84DPB920MF81
84DPD920MF81
84DPE920MF81
84DPF920MF81
84EPF920MF81
84EPG920MF81
84FPF920MF81
84FPH920MF81
84GPH920MF81
84GPJ920MF81
84HPJ920MF81
84HPK920MF81
84IPL920MF81
84JPM920MF81

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then

8/55

Pump Control Panels

Irrigation Pump Panel with Solid State Overload, Class 81
General

䊳
䊳
䊳
䊳
䊳
䊳

Ordering Information

Coil Table

Replace the (*) with a letter from the coil table.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/128.
Wiring Diagrams see page 8/145.
Replacement parts refer to instruction sheet SFIS-81010-1207.

60Hz Voltage

Letter

24
110–220
200–208
208–240
277
440–480

J
F
D
G
L
H

Siemens introduces its new Class 81 Irrigation Pump Panel. This
newest addition to the already extensive line of Siemens pump
panels was designed specifically for the agricultural market. It is
well suited for irrigation and similar pumping applications and is
built to withstand the harsh elements of the outdoors.
Typical applications include:
• Crop irrigation
• Sprinklers, misters and soakers
• Watering for livestock and other dairy applications
• Ground dewatering for excavation and construction sites
Features and Benefits
• Heavy-duty horsepower rated contactors sized 1/2 – 40hp to
provide reliable motor control and protection expected in the
most demanding applications

• Type 3R enclosure fabricated with galvannealed steel versusconventional cold rolled steel for superior corrosion resistance
• Rugged 30mm H-O-A switch and Start push button, which are
standard features, meet Type 3, 4, 12, and 13 specifications
and are oil and dust tight for durability
• Pre-punched opening with cover plate for convenient field
installation of a conduit hub should top entry be required
• Full gasketed door to ensure a dust tight and water tight seal
• Mounting flanges at top and bottom of enclosure for easy
mounting on poles or flat surfaces using keyhole slots
• Door is removable for ease of installation and maintenance
• Factory and field modifications for custom applications
• UL rated as service entrance equipment
• UL listed
• Pre-drilled mounted holes for MotorSaver®

Circuit Breaker
Max Hp
200
Volts
1⁄2
11⁄2
2
3
3
5
5
71⁄2
10
10
20

230
Volts
1⁄2
2
2
3
5
5
71⁄2
10
10
15
20

480
Volts
1
3
5
71⁄2
10
10
15
20
25
30
40

Contactor Amp Rating
25
25
25
25
30
30
40
50
60
60
90

Overload Amp Range
0.75-3
2.5-10
2.5-10
9-18
9-18
13-27
13-27
22-45
22-45
30-60
45-90

Breaker Amp Size
15
15
20
25
30
40
50
60
70
90
125

Catalog
Number
81AFB6MA*
81AFD6MA*
81AFD6MB*
81AFE6MC*
81BFE6MD*
81BFF6ME*
81CFF6MF*
81DFH6MG*
81EFH6MH*
81EFJ6MK*
81GEK6MN*

Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.

8/56

Siemens Industry, Inc.
Industrial Controls Catalog

Pump Control Panels

Class 87, 88
General

Features

Application

Features

▪ Fully Gasketed NEMA 3R Rainproof
Enclosures
▪ 100,000 Amp Interrupting Capacity
with Class R Fuses
▪ Heavy Duty NEMA Starters
▪ Solid State or Ambient Compensated
Bimetal Overload Relays
▪ Heavy Duty Disconnect Handle
▪ Available in Reduced Voltage Versions
▪ Bold Pilot Legend on Front
▪ Generous Accessory Space
▪ Copper Grounding Lug For Three
#6 Wires
▪ UL Listed for Outdoor Use and
Service Equipment File #E185287

Heavy duty pump control panels are
designed to withstand the most
demanding environments. Typical
applications include irrigation, agriculture,
petrochemical, wastewater treatment
and wherever motor control is
challenged by harsh elements.
Rugged pump control panels utilized
cold forming “tox” process. They are
more rainproof, sleet and ice
resistant than in the past.
Installation is easy. Panels are factory
wired to provide flexible control and
protect against short circuits and
overloads. Ample space is provided
for field modifications and installation
of accessories.
The pump control panels feature a full
sized removable auxiliary panel for the
mounting of accessories. The fusible
version features fuse clips for full sized
RK5 or compact class J fuses and
accessory mounting space for the
most commonly used accessories.
Class 87 pump panels become jockey
pump panels with the addition of a
pressure switch. The jockey pump’s
primary function is to maintain water
pressure at a preset level and thus
compensate for possible shortage of
water in the pumping system. When the
water pressure drops below the preset
level, the pressure switch energizes the
starter which in turn activates the jockey
pump. The water pressure is then
brought back up to the desired level. This
insures the maintenance of proper water
pressure at all times.

Specified by Fortune 500 companies,
Siemens NEMA starters offer
prolonged service under severe duty
conditions. NEMA rated, these starters
utilize large silver cadmium oxide
contacts and wide copper heat sinks
to ensure rapid heat dissipation and
maximum electrical life.

Siemens Industry, Inc.
Industrial Controls Catalog

ESP200 solid state overload relay
Refer to the section on Class 48 overload relays for features and benefits.
Pump panels are factory set at trip Class
10.
The ambient compensated bimetal
overload relays are designed to
parallel thermal characteristics of typical
pump motors. They prevent nuisance
trips that may result from operation of
the control in a higher ambient temperature than that at the pump. These relays
are trip-free, tamperproof and can be set
to reset automatically or manually.
HOA and Start Pushbutton
Every pump panel comes with an HOA
and a start pushbutton.
Half Size Starters
Siemens motor matched starters feature
all the rugged performance characteristics
of our NEMA rated starter sizes, but are
fractionally sized to more closely match
your exact motor rating. As a result,
significant economic savings are made
possible without sacrificing the reliability
you expect from a heavy duty starter.
These additional starter sizes have the
reserve capacity to handle occasional
plugging and jogging without de-rating
the device.
Siemens motor matched can save hundreds,
even thousands of dollars per project.
Siemens motor matched starters comply
with NEMA, UL and CSA standards.

8/57

Pump Control Panels

Class 87, 88
General

Panels are predrilled for easy repositioning
of the fuse trailer block to accommodate
250 and 600 volt fuses and full sized RK
or compact J fuses. Circuit breakers are
also available.
Heavy Duty Fusible
Disconnect Switch
The disconnect switch has the following
advantages:
▪ Visible blades for the highest
level of safety
▪ Double Break Switching Action
to reduce arcing, increase lifetime
and eliminate the “electric hinge”
▪ Oversized lugs are standard
▪ Line side shield to help guard
personnel from contact with live parts
Motor Circuit Protector
The motor circuit protector provides fast,
accurate fault clearing that will minimize
damage to the motor and control
apparatus and protect branch circuit
conductors. Continuous current ratings
and adjustable trip ranges meet NEC
requirements for full load and locked
rotor currents. The adjustable
instantaneous trip point can be set
precisely to assure fault protection
and eliminate nuisance tripping.
Removable Door
Enclosure door may be lifted off to make
wiring easier.
Mounting Flanges
Convenient flanges at top and bottom
of the enclosure provide easy mounting.
They fit pole or flat surfaces using
keyhole slots.
Quarter Turn Latches
Quarter turns are utilized to secure the
door.
Wind Catches
A wind catch is provided to prevent the
door from slamming shut (or open) due
to high wind conditions.

8/58

Safety Disconnect Handle
Up to three padlocks can be used to lock
the disconnect in the OFF position.
Maintenance work can be performed
without hazard to personnel.
External Reset
The overload relay may be quickly reset
by means of a button on the front of the
enclosure.
Bold Pilot Legend
Provides positive indication of the
selector switch position for use to
stop the pump motor.
Ground Lugs
Insures proper connecting of ground
wires and lightning arresters.
UL Listed
Assures proper construction throughout
control panel.
Reduced Voltage
Available in part winding, wye delta and
auto transformer types, these controls
may be necessary where the power
company limits the amount of current
drawn from its lines, or where starting
torque must be reduced.
Fully gasketed NEMA 3/12 weatherproof enclosures are supplied with
Class 88 reduced voltage starters.
Part Winding Starters apply starting
current in timed steps to minimize
voltage fluctuations.
Auto Transformer Starters maintain
a closed circuit during transition and
eliminate voltage or current surges.
They draw less current than part winding
starters and are well suited for starting
motors over 20 Hp.
Wye Delta starters and motors are
used in areas where the power supply is
inadequate to supply full starting current
without objectionable voltage drop or for
applications where low starting torque is
required. Centrifugal pumps and similar
apparatus requiring a low starting torque
are typical applications. Both ends of all
three windings of the wye delta motor
are brought out so that they may be
accessible for reconnecting from wye
to delta.

Auxiliary Equipment
Pilot Lights are easily installed on the
enclosure. Oil Tight and Heavy Duty, they
meet NEMA A600 requirements.
Lightning Arresters protect the control panel from lightning induced surges.
Undervoltage and Phase Sensing
Relays protect the pump against low
voltage, voltage imbalance, loss of phase
and phase reversal.
Anti-Backspin Timers prevent the
motor from starting during motor/shaft
backspin.
The TOX Box
Siemens uses the TOX process to
manufacture the enclosures for the
pump panels.
Advantages of the TOX process:
▪ Joints are 50-70% stronger
▪ Since the TOX process compresses
the metal at the joint, it does not
leave the high stresses in the metal
▪ Increased corrosion resistance.
The protective layer on the metal is
not damaged in the process, but
instead flows with the material
Class 87 NEMA Vacuum Starter
Pump Control Panels
The Siemens vacuum starter pump
controllers are designed for the harshest
environments. Typical environments
include chemical, petrochemical, waste
water treatment and mining.
Contaminations present in these
severe environments are detrimental
to conventional air-break contacts
decreasing their life expectancy and
reliability. The Siemens vacuum starter
pump controllers are well suited for
these environments because the
contacts are contained in hermetically
sealed contact tubes. This prevents
contaminates in the atmosphere from
affecting the operation of the contacts.
Additionally, neither arcs nor arcing
gases are produced which dramatically
increases the electrical endurance of
the contacts.

Siemens Industry, Inc.
Industrial Controls Catalog

Pump Control Panels

Standard Pump Panel with Solid State Overload, Class 87
Selection

䊳
䊳
䊳
䊳
䊳
䊳

䊳

Ordering Information

Coil Table

Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/128.
Wiring Diagrams see page 8/145.
Replacement Parts see page 8/157.
Sizes 1-4 will be supplied standard with a 240/480 volt coil. To
change the coil voltage, change the 8th character in the catalog
number to the letter shown in the coil table.
Sizes 5 & 6 will be supplied standard with a 480 volt coil. To change
the coil voltage, change the 8th character in the catalog number to
the letter shown in the coil table.

60Hz Voltage

Letter

24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
220–240/440–480
277
440–480
550–600

J
F
A
D
G
C
L
H
E

Fusible Disconnect
Max Hp
200
Volts
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2
3
71⁄2
71⁄2
10
10
10
15
15
20
25
30
40
75

230
Volts
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2
3
71⁄2
71⁄2
10
15
15
20
20
25
30
40
50
100

460
Volts
1
5
71⁄2
71⁄2
15
15
15
25
30
30
50
50
75
100
200
250
—
—
—
—
—
—
—
—
—
—
—
—
—
—

575
Volts
1
5
10
10
15
15
25
25
30
30
50
50
75
100
200
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

NEMA
Size
1
1
1
1
—
—
2
2
—
—
3
3
—
4
5
6
1
1
1
1
—
2
2
—
—
3
3
—
4
5

Overload
Amp
Range
0.75–3.4
3–12
5.5–22
5.5–22
10–40
10–40
13–52
13–52
13–52
13–52
25–100
25–100
50–200
50–200
55–250
160–630
3–12
5.5–22
10–40
10–40
10–40
13–52
13–52
25–100
25–100
25–100
25–100
50–200
50–200
55–250

Half
Size
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
—
—
31⁄2
—
—
—
—
—
—
—
13⁄4
—
—
21⁄2
21⁄2
—
—
31⁄2
—
—

Disc.
Amp
Range
30
30
30
60
30
60
60
100
60
100
100
200
200
200
400
600
30
30
30
60
60
60
100
60
100
100
200
200
200
400

Frame
Size
A
A1
A1
A1
A1
A1
B
B
B
B
B
B
B
B
—
—
A1
A1
A1
A1
A1
B
B
B
B
B
B
B
B
—

Fuse
Clip
Amp / Volts
30A/600V
30A/600V
30A/600V
60A/600V
30A/600V
60A/600V
60A/600V
100A/600V
60A/600V
100A/600V
100A/600V
200A/600V
200A/600V
200A/600V
400A/600V
600A/600V
30A/250V
30A/250V
30A/250V
60A/250V
60A/250V
60A/250V
100A/250V
60A/250V
100A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V

Catalog
Number
87DUB6FC
87DUC6FC
87DUD6FC
87DUD60C
87EUE6FC
87EUE60C
87FUF6FC
87FUF60C
87GUG6FC
87GUG60C
87HUG6FC
87HUG60C
87IUH6FC
87JUH6FC
87LPU6FH
87MSW6FH
87DUC6LC
87DUD6LC
87DUE6LC
87DUE6PC
87EUE6LC
87FUF6LC
87FUF6PC
87GUG6LC
87GUG6PC
87HUG6LC
87HUG6PC
87IUH6LC
87JUH6LC
87LPU6LG

List
Price $

Circuit Breaker
Max Hp
200
Volts
1
⁄2
2
3
71⁄2
—
10
15
25
30
40
50
75
100
150

230
Volts
1
⁄2
2
3
71⁄2
—
15
20
30
40
50
75
100
125
200

460
Volts
1
5
71⁄2
10
15
25
30
50
75
100
150
200
250
400

575
Volts
1
5
10
—
15
25
30
50
75
100
200
200
300
400

NEMA
Size
1
1
1
1
—
2
—
3
—
4
5
5
6
6

Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).

Siemens Industry, Inc.
Industrial Controls Catalog

Half
Size
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—

Overload
Amp
Range
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
160–630

Frame
Size
A
A1
A1
A1
A1
B
B
B
B
B
—
—
—
—

 Not available on Size 5 and
 For an overload amp range

Motor Circuit
Interrupter
ETI Amps
3
10
25
30
40
50
100
100
125
150
250
400
400
600

larger.
of 0.25-1A, change the
5th character from a ‘B’ to an ‘A’.

Product Category: NEMA

Catalog
Number
87DUB6MC
87DUC6MC
87DUD6MC
87DUE6MC
87EUE6MC
87FUF6MC
87GUG6MC
87HUG6MC
87IUH6MC
87JUH6MC
87LPT6MH
87LPU6MH
87MSW6MH
87MSX6MH

List
Price $

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.

8/59

Pump Control Panels

Pump Panel with Ambient Compensated Bimetal Overload, Class 87
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳

䊳

Coil Table

Heater elements for bimetal overloads see page 8/150 (6-Required).
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/128.
Wiring Diagrams see page 8/145.
Replacement Parts see page 8/157.

Sizes 1-4 will be supplied standard with a 230/480 volt coil. To change the coil
voltage, change the 8th character in the catalog number to the letter shown in
the coil table.
Sizes 5 & 6 will be supplied standard with a 480 volt coil. To change the coil
voltage, change the 8th character in the catalog number to the letter shown
in the coil table.

60Hz Voltage

Letter

24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
220–240/440–480
277
440–480
550–600

J
F
A
D
G
C
L
H
E

Fusible Disconnect
Max HP
200V

230V

460V

575V

NEMA Size

Half Size

—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—

10
10
15
15
25
25
30
30
50
50
75
100

10
10
15
15
25
25
30
30
50
50
75
100

1
1

—
—

—
—

13⁄4
13⁄4

2
2

—
—

—
—

21⁄2
21⁄2

3
3

—
—

—

31⁄2

71⁄2
71⁄2
10
10
10
15
25
25
30
40

71⁄2
71⁄2
10
15
15
20
30
30
40
50

—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—

4
1
1

—
—
—

—

13⁄4

2
2

—
—

—

21⁄2

3
3

—
—

—

31⁄2

4

—

Disc
Amp Rating
30
60
30
60
60
100
60
100
100
200
200
200
30
60
60
60
100
100
100
200
200
200

Fuse Clip
Amps/Volts

Catalog Number

30A/600V
60A/600V
30A/600V
60A/600V
60A/600V
100A/600V
60A/600V
100A/600V
100A/600V
200A/600V
200A/600V
200A/600V
30A/250V
60A/250V
60A/250V
60A/250V
100A/250V
100A/250V
100A/250V
200A/250V
200A/250V
200A/250V

87DAE6FC
87DAE60C
87EAF6FC
87EAF60C
87FAJ6FC
87FAJ60C
87GAK6FC
87GAK60C
87HAN6FC
87HAN60C
87IAP6FC
87JAR6FC
87DAE6LC
87DAE6PC
87EAG6LC
87FAJ6LC
87FAJ6PC
87GAL6LC
87HAN6LC
87HAN6PC
87IAP6LC
87JAR6LC

Catalog Number

List Price $

List Price $

Circuit Breaker
Max HP
200V

230V

460V

575V

NEMA Size

Half Size

⁄
1
3
71⁄2
71⁄2
10

12

⁄
1
3
71⁄2
71⁄2
10

1
3
71⁄2
10
15

1
3
71⁄2
10
15

1
1
1
1

—
—
—
—

—

—

—
—

13⁄4
13⁄4

15
25
30

20
25
30

2
2

—
—

—

—

—
—

21⁄2
21⁄2

50
75
100

50
75
100

12

—

—

10

15

—

—

15
25
30
40

20
30
40
50

3

—

—

31⁄2

4

—

Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.

8/60

 Not

Motor Circuit
Interrupter
ETI Amps
3
10
25
30
40
50
40
50
50
100
100
125
150

87DAA6MC
87DAB6MC
87DAD6MC
87DAE6MC
87EAF6MC
87EAG6MC
87FAH6MC
87FAJ6MC
87GAK6MC
87GAL6MC
87HAN6MC
87IAP6MC
87JAR6MC

available on Size 5 or above.

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Vacuum Starter Pump Panels

With Solid-State Overload Relay, Class 87
Selection
Coil Table

Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳

Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/128.
Wiring Diagrams see page 8/145.
Replacement Parts see page 8/157.
Sizes 4-6 will be supplied standard with a 480 volt coil. To change
the coil voltage, change the 8th character in the catalog number to
the letter shown in the coil table.

60Hz Voltage

***

24 Separate Control
120 Separate Control
200–208
220–240
277
440–480
550–600

J
F
D
G
L
H
E

Fusible Disconnect
Max Hp
460 Volts
100
200

575 Volts
100
200

NEMA Size
4
5

Overload Range
55-250A
55-250A

Fuse Clip
Amps/Volts
200A/600V
400A/600V

Catalog Number
87JCM4F*
87LCU4F*

List Price $

575 Volts
100
200
300
400

NEMA Size
4
5
6
6

Overload Range
55-250A
55-250A
160-630A
160-630A

Circuit Breaker
Rating Amps
250A
400A
400A
600A

Catalog Number
87JCM4M*
87LCT4M*
87MCW4M*
87MCX4M*

List Price $

Circuit Breaker
Max Hp
460 Volts
100
200
250
400

Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.

Siemens Industry, Inc.
Industrial Controls Catalog

Product Category: NEMA

8/61

Reduced Voltage Pump Panels

Auto Transformer & Part Winding [2 Step] with Solid State Overload, Class 88
Selection
Coil and Control Voltage

Ordering Information
䊳
䊳
䊳
䊳
䊳

Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/128.
Wiring Diagrams see pages 8/138 and 8/139.
Replacement Parts see page 8/157.

The coil voltage on the contactors will be
the motor voltage. A CPT will be supplied
to provide the control voltage. The control
voltage will be 120V.
To change the control voltage to customer
supplied (no CPT included), change the
9th character to the following:
for 24V , use ”J”
for 120V, use ”F”

Auto Transformer Type
Overload
Motor
Voltage

230

460

Fusible Disconnect

Circuit Breaker

Max
Hp

Amp
Range

Frame
Size

NEMA
Size

Half
Size

Fuse Clip Size
Amps/Volts

Catalog
Number

15

13–52

B

2

—

60A/250V

20

25–100

B

—

21⁄2

100A/250V

30

25–100

B

3

—

40

50–200

B

—

50

50–200

B

75

55–250

100

List
Price $

Circuit Breaker
Amps

Catalog
Number

88FUFT2FG

50

88FUFT2MG

88GUGT2FG

100

88GUGT2MG

100A/250V

88HUGT2FG

100

88HUGT2MG

31⁄2

200A/250V

88IUHT2FG

125

88IUHT2MG

4

—

200A/250V

88JUHT2FG

150

88JUHT2MG

—

5

—

—

—

250

88LPST2MG

55–250

—

5

—

400A/250V

88LPUT2FG

400

88LPUT2MG

200

160–630

—

6

—

—

—

600

88MSXT2MG

25

13–52

B

2

—

60A/600V

88FUFT4FH

50

88FUFT4MH

30

25–100

B

—

21⁄2

60A/600V

88GUGT4FH

50

88GUGT4MH

50

25–100

B

3

—

100A/600V

88HUGT4FH

100

88HUGT4MH

75

50–200

B

—

31⁄2

200A/600V

88IUHT4FH

125

88IUHT4MH

100

50–200

B

4

—

200A/600V

88JUHT4FH

150

88JUHT4MH

150

55–250

—

5

—

—

—

250

88LPST4MH

200

55–250

—

5

—

400A/600V

88LPSP2MH

400

88LPST4MH

400

160–630

—

6

—

600A/600V

88MSXT4FH

600

88MSXT4MH

—
—

—

List
Price $

Part Winding 2 Step
Overload
Motor
Voltage

230

460

Fusible Disconnect

Amp
Range

Frame
Size

NEMA
Size

Half
Size

Fuse Clip Size
Amps/Volts

Catalog
Number

Circuit Breaker
Amps

Catalog
Number

20

10–40

A1

—

13⁄4

100A/250V

25

13–52

B

2

—

100A/250V

88EUEP2FG

100

88EUEP2MG

88FUFP2FG

100

40

25–100

B

—

21⁄2

88FUFP2MG

200A/250V

88GUGP2FG

100

50

25–100

B

3

88GUGP2MG

—

200A/250V

88HUGP2FG

150

60

50–200

B

88HUGP2MG

—

31⁄2

200A/250V

88IUHP2FG

250

75

50–200

88IUHP2MG

B

4

—

400A/250V

88JUHP2FG

250

125

88JUHP2MG

55–250

—

5

—

—

—

400

88LPSP2MG

150

55–250

—

5

—

600A/250V

88LPUP2FG

600

88LPUP2MG

30

10–40

A1

—

13⁄4

100A/600V

88EUEP4FH

100

88EUEP4MH

40

13–52

B

2

—

100A/600V

88FUFP4FH

100

88FUFP4MH

60

25–100

B

—

21⁄2

200A/600V

88GUGP4FH

100

88GUGP4MH

75

25–100

B

3

—

200A/600V

88HUGP4FH

150

88HUGP4MH

100

50–200

B

—

31⁄2

200A/600V

88IUHP4FH

250

88IUHP4MH

150

50–200

B

4

—

400A/600V

88JUHP4FH

250

88JUHP4MH

250

55–250

—

5

—

—

—

400

88LPSP4MH

350

55–250

—

5

—

600A/600V

88LPUP4FH

600

88LPSP4MH

Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).

8/62

Circuit Breaker

Max
Hp

List
Price $

—

—

List
Price $

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009. Continue
to order enclosed starters with the ESP100 OLR until
then.

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Reduced Voltage Pump Panels

Wye Delta with Solid State Overload, Class 88
Selection
Coil and Control Voltage

Ordering Information
䊳
䊳
䊳
䊳
䊳

Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/128.
Wiring Diagrams see pages 8/140 and 8/141.
Replacement Parts see page 8/157.

The coil voltage on the contactors will be
the motor voltage. A CPT will be supplied
to provide the control voltage. The control
voltage will be 120V.
To change the control voltage to customer
supplied (no CPT included), change the
9th character to the following:
for 24V , use ”J”
for 120V, use ”F”

Wye Delta
Overload
Motor
Max Amp
Voltage Hp
Range

200

230

460

575

Frame NEMA Half Fuse Clip Size
Size
Size
Size Amps/Volts

Motor
Circuit
Interruter
ETI Amps

Open Transition
Fusible Disconnect

Circuit Breaker

Catalog
Number

Catalog
Number

List
Price $

List
Price $

Closed Transition
Fusible Disconnect

Circuit Breaker

Catalog
Number

Catalog
Number

List
Price $

10

10–40

A1

1

—

60A/250V

50

88DUE06FD

88DUE06MD

88DUEC6FD

88DUEC6MD

15

10–40

A1

—

13⁄4

100A/250V

100

88EUE06FD

88EUE06MD

88EUEC6FD

88EUEC6MD

20

13–52

B

2

—

100A/250V

100

88FUF06FD

88FUF06MD

88FUFC6FD

88FUFC6MD

30

25–100

B

—

21⁄2

200A/250V

125

88GUG06FD

88GUG06MD

88GUGC6FD

88GUGC6MD

40

25–100

B

3

—

200A/250V

150

88HUG06FD

88HUG06MD

88HUGC6FD

88HUGC6MD

50

50–200

B

—

31⁄2

200A/250V

250

88IUH06FD

88IUH06MD

88IUHC6FD

88IUHC6MD

60

50–200

B

4

—

400A/250V

250

88JUH06FD

88JUH06MD

88JUHC6FD

88JUHC6MD

75

55–250

—

5

—

400A/600V

400

88LPS06FD

88LPS06MD

88LPSC6FD

88LPSC6MD

150

55–250

—

5

—

600A/600V

600

88LPU06FD

88LPU06MD

88LPUC6FD

300

160–630 —

6

—

—

800

—

88MSX06MD

—

10

10–40

A1

1

—

60A/250V

50

88DUE02FG

88DUE02MG

88DUEC2FG

88DUEC2MG

15

10–40

A1

—

13⁄4

60A/250V

50

88EUE02FG

88EUE02MG

88EUEC2FG

88EUEC2MG

25

13–52

B

2

—

100A/250V

100

88FUF02FG

88FUF02MG

88FUFC2FG

88FUFC2MG

30

25–100

B

—

21⁄2

200A/250V

100

88GUG02FG

88GUG02MG

88GUGC2FG

88GUGC2MG

50

25–100

B

3

—

200A/250V

150

88HUG02FG

88HUG02MG

88HUGC2FG

88HUGC2MG

60

50–200

B

—

31⁄2

200A/250V

250

88IUH02FG

88IUH02MG

88IUHC2FG

88IUHC2MG

75

50–200

B

4

—

400A/250V

250

88JUH02FG

88JUH02MG

88JUHC2FG

88JUHC2MG

100

55–250

—

5

—

400A/250V

400

88LPS02FG

88LPS02MG

88LPSC2FG

88LPSC2MG

150

55–250

—

5

—

600A/250V

600

88LPU02FG

88LPU02MG

88LPUC2FG

350

160–630 —

6

—

—

1200

—

—

88MSX02MG

—

—

88MSXC2MG

15

10–40

A1

1

—

60A/600V

30

—

—

—

—

—

—

30

10–40

A1

—

13⁄4

60A/600V

50

88EUE04FH

88EUE04MH

88EUEC4FH

88EUEC4MH

40

13–52

B

2

—

100A/600V

100

88FUF04FH

88FUF04MH

88FUFC4FH

88FUFC4MH

60

25–100

B

—

21⁄2

200A/600V

100

88GUG04FH

88GUG04MH

88GUGC4FH

88GUGC4MH

75

25–100

B

3

—

200A/600V

125

88HUG04FH

88HUG04MH

88HUGC4FH

88HUGC4MH

100

50–200

B

—

31⁄2

200A/600V

150

88IUH04FH

88IUH04MH

88IUHC4FH

88IUHC4MH

150

50–200

B

4

—

400A/600V

250

88JUH04FH

88JUH04MH

88JUHC4FH

88JUHC4MH

200

55–250

—

5

—

400A/600V

400

88LPS04FH

88LPU04MH

88LPSC4FH

88LPSC4MH

300

55–250

—

5

—

600A/600V

600

88LPU04FH

88LPU04MH

88LPUC4FH

700

160–630 —

6

—

—

1200

—

—

88MSX04MH

—

—

88MSXC4MH

15

10–40

A1

1

—

60A/600V

30

—

—

—

—

—

—

30

10–40

A1

—

13⁄4

60A/600V

50

88EUE05FE

88EUE05ME

88EUEC5FE

88EUEC5ME

40

13–52

B

2

—

100A/600V

50

88FUF05FE

88FUF05ME

88FUFC5FE

88FUFC5ME

60

25–100

B

—

21⁄2

200A/600V

100

88GUG05FE

88GUG05ME

88GUGC5FE

88GUGC5ME

75

25–100

B

3

—

200A/600V

125

88HUG05FE

88HUG05ME

88HUGC5FE

88HUGC5ME

100

50–200

B

—

31⁄2

200A/600V

150

88IUH05FE

88IUH05ME

88IUHC5FE

88IUHC5ME

150

50–200

B

4

—

400A/600V

250

88JUH05FE

88JUH05ME

88JUHC5FE

88JUHC5ME

200

55–250

—

5

—

400A/600V

400

88LPS05FE

88LPU05ME

88LPSC5FE

88LPSC5ME

300

55–250

—

5

—

600A/600V

400

88LPU05FE

88LPU05ME

88LPUC5FE

700

160–630 —

6

—

—

1200

—

88MSX05ME

—

Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).

Siemens Industry, Inc.
Industrial Controls Catalog

—

—

—

—

List
Price $

88LPUC6MD
—

88MSXC6MD

88LPUC2MG
—

88LPUC4MH
—

88LPUC5ME
—

88MSXC5ME

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009. Continue
to order enclosed starters with the ESP100 OLR until
then.

Product Category: NEMA

8/63

Reduced Voltage Heavy Duty Starters

Features and Benefits
General

Siemens manufactures the three commonly used electromechanical reduced
voltage starters. Each one is designed
for specific application requirements
and consists of auto transformer,
wye-delta and partwinding starters.

The reduced voltage starter:
▪ Reduces inrush current
▪ Provides smoother acceleration of the
load
▪ Reduces starting torque
▪ Reduces stresses on mechanical
linkages

Combination and non-combination
reduced voltage starter sizes range
from 0 to 6 including Siemens exclusive
motormatched half-sizes. Enclosure
types include 1, 3R/12, 4 painted and
4/4X stainless steel. UL listed file
#E14900 (class 36); file #E185287
(class 37). CSA certified file #LR 6535
(class 36 & 37).

Auto Transformer Starter
▪ Maximum torque per amp
▪ Three coil auto transformer for balanced starting currents
▪ 50, 65 and 80% voltage taps
▪ Closed circuit transition
▪ Adjustable starting time
▪ ESP200 overload as standard
▪ CPT supplied as standard
▪ Wide range of factory modifications

Wye-Delta Starter
▪ Lowest starting torque
▪ Closed or open circuit transition
▪ Adjustable starting time
▪ ESP200 overload as standard
▪ CPT supplied as standard
▪ Wide range of factory modifications

Part-Winding Starter
▪ Simplest design – most economical
▪ Adjustable starting time
▪ ESP200 overload as standard
▪ CPT supplied as standard
▪ Wide range of factory modifications

Various Methods of Electro-Mechanical Reduced Voltage Motor Starting
— A General Comparison
Autotransformer
Characteristic

Starting current drawn from
line as % of that which would
be drawn upon full voltage
starting
Starting current drawn by the
motor
Starting torque developed as
% of that which would be
developed on full voltage
starting
Smoothness of acceleration

Part-Winding

65%
Tap

80%
Tap

2 step

25%

42%

64%

65%

33%

50%

65%

80%

65%

58%

64%

40%

33%

Third in order of
Smoothness

Second in order of
Smoothness

5 seconds max.
Limited by motor
design

5-60 seconds
Limited by motor
design

Fixed

Fixed

25%
42%
Increases slightly
with speed

Allowable accelerating times
(typical)

First in order of
Smoothness
15 seconds at 200HP
max. or 30 seconds on
200HP based on
NEMA medium duty
transformers

Starting current and torque
and adjustments

Adjustable within limits
of various taps

8/64

Wye-Delta

50%
Tap

Siemens Industry, Inc.
Industrial Controls Catalog

Reduced Voltage Heavy Duty Starters

Auto Transformer with Solid State Overload, Class 36 & 37
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳

Coil and Control Voltage
The coil voltage will always match the
motor voltage.
As standard, a CPT is supplied and 120V
control voltage is utilized.
To change to 120V separate control
voltage (CPT not supplied), change the
9th character to “F”.
To change to 24VAC separate control
voltage (CPT not supplied), change the
9th character to “J”.

Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/126.
Wiring Diagrams see page 8/139.
Replacement Parts see page 8/157.
For additional enclosure options see page 8/98.

NEMA 1 General Purpose Enclosures
Non-Combination
Enclosure

Overload
Motor Max NEMA Half Amp
Voltage Hp
Size
Size Range

200

230

460

575

Frame Catalog
Size
Number

List
Price $

Combination Non-Fusible
Disconnect
Catalog
Number

List
Price $

Fuse Clip
Size
Amps/Volts

Combination Fusible
Disconnect
Catalog
Number

List
Price $

Combination Circit
Circuit Breaker
Breaker Catalog
List
Amps
Number
Price $

10

—

13⁄4

10–40

A1

36EUET6BD

37EUET6BDD

60A/250V

37EUET6BDF

50

37EUET6BDP

10

2

—

13–52

B

36FUFT6BD

37FUFT6BDD

60A/250V

37FUFT6BDF

50

37FUFT6BDP

15

—

21⁄2

25–100

B

36GUGT6BD

37GUGT6BDD

100A/250V

37GUGT6BDF

100

37GUGT6BDP

25

3

—

25–100

B

36HUGT6BD

37HUGT6BDD

100A/250V

37HUGT6BDF

100

37HUGT6BDP

30

—

31⁄2

50–200

B

36IUHT6BD

37IUHT6BDD

200A/250V

37IUHT6BDF

125

37IUHT6BDP

40

4

—

50–200

B

36JUHT6BD

37JUHT6BDD

200A/250V

37JUHT6BDF

150

37JUHT6BDP

50

5

—

55–250

—

—

—

—

250

37LPST6BDP

75

5

—

55–250

—

36LPUT6BD

37LPUT6BDD

400A/250V

37LPUT6BDF

400

37LPUT6BDP

150

6

—

160–630 —

36MPXT6BD

37MPXT6BDD

600A/250V

37MPXT6BDF

600

37MPXT6BDP

10

—

13⁄4

10–40

A1

36EUET2BG

37EUET2BGD

60A/250V

37EUET2BGF

50

37EUET2BGP

15

2

—

13–52

B

36FUFT2BG

37FUFT2BGD

60A/250V

37FUFT2BGF

50

37FUFT2BGP

20

—

21⁄2

25–100

B

36GUGT2BG

37GUGT2BGD

100A/250V

37GUGT2BGF

100

37GUGT2BGP

30

3

—

25–100

B

36HUGT2BG

37HUGT2BGD

100A/250V

37HUGT2BGF

100

37HUGT2BGP

40

—

31⁄2

50–200

B

36IUHT2BG

37IUHT2BGD

200A/250V

37IUHT2BGF

125

37IUHT2BGP

50

4

—

50–200

B

36JUHT2BG

37JUHT2BGD

200A/250V

37JUHT2BGF

150

37JUHT2BGP

75

5

—

55–250

—

—

—

—

250

37LPST2BGP

100

5

—

55–250

—

36LPUT2BG

37LPUT2BGD

400A/250V

37LPUT2BGF

400

37LPUT2BGP

200

6

—

160–630 —

36MPXT2BG

37MPXT2BGD

600A/250V

37MPXT2BGF

600

37MPXT2BGP

15

—

13⁄4

10–40

A1

36EUET4BH

37EUET4BHD

60A/250V

37EUET4BHF

50

37EUET4BHP

25

2

—

13–52

B

36FUFT4BH

37FUFT4BHD

60A/250V

37FUFT4BHF

50

37FUFT4BHP

30

—

21⁄2

13–52

B

36GUGT4BH

37GUGT4BHD

100A/250V

37GUGT4BHF

100

37GUGT4BHP

50

3

—

25–100

B

36HUGT4BH

37HUGT4BHD

100A/250V

37HUGT4BHF

100

37HUGT4BHP

75

—

31⁄2

50–200

B

36IUHT4BH

37IUHT4BHD

200A/250V

37IUHT4BHF

125

37IUHT4BHP

100

4

—

50–200

B

36JUHT4BH

37JUHT4BHD

200A/250V

37JUHT4BHF

150

37JUHT4BHP

150

5

—

55–250

—

—

—

—

250

37LPST4BHP

200

5

—

55–250

—

36LPUT4BH

37LPUT4BHD

400A/250V

37LPUT4BHF

400

37LPUT4BHP

400

6

—

160–630 —

36MPXT4BH

37MPXT4BHD

600A/250V

37MPXT4BHF

600

37MPXT4BHP

15

—

13⁄4

10–40

36EUET5BE

37EUET5BED

60A/250V

37EUET5BEF

50

37EUET5BEP

25

2

—

---13–52 B

36FUFT5BE

37FUFT5BED

60A/250V

37FUFT5BEF

50

37FUFT5BEP

30

—

21⁄2

13–52

B

36GUGT5BE

37GUGT5BED

100A/250V

37GUGT5BEF

100

37GUGT5BEP

50

3

—

25–100

B

36HUGT5BE

37HUGT5BED

100A/250V

37HUGT5BEF

100

37HUGT5BEP

75

—

31⁄2

50–200

B

36IUHT5BE

37IUHT5BED

200A/250V

37IUHT5BEF

125

37IUHT5BEP

100

4

—

50–200

B

36JUHT5BE

37JUHT5BED

200A/250V

37JUHT5BEF

150

37JUHT5BEP

150

5

—

55–250

—

—

—

—

250

37LPUT5BEP

200

5

—

55–250

—

36LPUT5BE

37LPUT5BED

400A/250V

37LPUT5BEF

400

37LPUT5BEP

400

6

—

160–630 —

36MPXT5BE

37MPXT5BED

600A/250V

37MPXT5BEF

600

37MPXT5BEP

A1

Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).

Siemens Industry, Inc.
Industrial Controls Catalog

—

—

—

—

—

—

—

—

—

—

—

—

—

—

—

—

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009. Continue
to order enclosed starters with the ESP100 OLR until
then.

Product Category: NEMA

8/65

Reduced Voltage Heavy Duty Starters

2 Step Part Winding with Solid State Overload, Class 36 & 37
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳

Coil and Control Voltage
The coil voltage will always match the
motor voltage.
As standard, a CPT is supplied and 120V
control voltage is utilized.
To change to 120V separate control
voltage (CPT not supplied), change
the 9th character to “F”.
To change to 24VAC separate control
voltage (CPT not supplied), change the
9th character to “J”.

Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/126.
Wiring Diagrams see page 8/138.
Replacement Parts see page 8/157.
For additional enclosure options see page 8/98.

NEMA 1 General Purpose Enclosures
Non-Combination
Enclosure

Overload
Motor
Voltage

200

230

460

575

Max NEMA
Hp
Size

Half
Size

Amp
Range

Frame Catalog
Size
Number

71⁄2
10
15
20
30
40
50
75
100
150
71⁄2
10
20
25
30
50
60
75
125
150
300
10
15
30
40
60
75
100
150
250
350
600
10
15
30
40
60
75
100
150
250
350
600

—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—

5.5–22
5.5–22
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
5.5–22
5.5–22
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
5.5–22
5.5–22
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
5.5–22
5.5–22
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630

A1
A1
A1
B
B
B
B
B
—
—
A1
A1
A1
B
B
B
B
B
—
—
—
A1
A1
A1
B
B
B
B
B
—
—
—
A1
A1
A1
B
B
B
B
B
—
—
—

0
1
—
2
—
3
—
4
5
5
0
1
—
2
—
3
—
4
5
5
6
0
1
—
2
—
3
—
4
5
5
6
0
1
—
2
—
3
—
4
5
5
6

36CUDP6BD
36DUDP6BD
36EUEP6BD
36FUFP6BD
36GUGP6BD
36HUGP6BD
36IUHP6BD
36JUHP6BD
—
36LPUP6BD
36CUDP2BG
36DUDP2BG
36EUEP2BG
36FUFP2BG
36GUGP2BG
36HUGP2BG
36IUHP2BG
36JUHP2BG
—
36LPUP2BG
36MPXP2BG
36CUDP4BH
36DUDP4BH
36EUEP4BH
36FUFP4BH
36GUGP4BH
36HUGP4BH
36IUHP4BH
36JUHP4BH
—
36LPUP4BH
36MPXP4BH
36CUDP5BE
36DUDP5BE
36EUEP5BE
36FUFP5BE
36GUGP5BE
36HUGP5BE
36IUHP5BE
36JUHP5BE
—
36LPUP5BE
36MPXP5BE

Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).

8/66

List
Price $

—

—

—

—

Combination Non-Fusible
Disconnect
Fuse Clip
Catalog
List
Size
Number
Price $
Amps/Volts

Combination Fusible
Disconnect

37CUDP6BDD
37DUDP6BDD
37EUEP6BDD
37FUFP6BDD
37GUGP6BDD
37HUGP6BDD
37IUHP6BDD
37JUHP6BDD
—
37LPUP6BDD
37CUDP2BGD
37DUDP2BGD
37EUEP2BGD
37FUFP2BGD
37GUGP2BGD
37HUGP2BGD
37IUHP2BGD
37JUHP2BGD
—
37LPUP2BGD
37MPXP2BGD
37CUDP4BHD
37DUDP4BHD
37EUEP4BHD
37FUFP4BHD
37GUGP4BHD
37HUGP4BHD
37IUHP4BHD
37JUHP4BHD
—
37LPUP4BHD
37MPXP4BHD
37CUDP5BED
37DUDP5BED
37EUEP5BED
37FUFP5BED
37GUGP5BED
37HUGP5BED
37IUHP5BED
37JUHP5BED
—
37LPUP5BED
37MPXP5BED

37CUDP6BDF
37DUDP6BDF
37EUEP6BDF
37FUFP6BDF
37GUGP6BDF
37HUGP6BDF
37IUHP6BDF
37JUHP6BDF
—
37LPUP6BDF
37CUDP2BGF
37DUDP2BGF
37EUEP2BGF
37FUFP2BGF
37GUGP2BGF
37HUGP2BGF
37IUHP2BGF
37JUHP2BGF
—
37LPUP2BGF
37MPXP2BGF
37CUDP4BHF
37DUDP4BHF
37EUEP4BHF
37FUFP4BHF
37GUGP4BHF
37HUGP4BHF
37IUHP4BHF
37JUHP4BHF
—
37LPUP4BHF
37MPXP4BHF
37CUDP5BEF
37DUDP5BEF
37EUEP5BEF
37FUFP5BEF
37GUGP5BEF
37HUGP5BEF
37IUHP5BEF
37JUHP5BEF
37LPSP5BEF
37LPUP5BEF
37MPXP5BEF

—

—

—

—

60A/250V
60A/250V
100A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
—
600A/250V
60A/250V
60A/250V
100A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
—
600A/250V
1200A/250V
30A/600V
60A/600V
60A/600V
100A/600V
200A/600V
200A/600V
200A/600V
400A/600V
—
600A/600V
1200A/600V
30A/600V
60A/600V
60A/600V
60A/600V
100A/600V
200A/600V
400A/600V
400A/600V
400A/600V
600A/600V
1200A/600V

Catalog
Number

List
Price $

—

—

—

Circuit
Breaker
Amps
30
50
100
100
125
150
250
400
600
600
30
50
100
100
100
150
250
250
400
600
1200
30
30
50
100
100
125
150
250
400
600
1200
30
30
50
50
100
125
150
250
—
400
1200

Combination Circit
Breaker
Catalog
Number
37CUDP6BDP
37DUDP6BDP
37EUEP6BDP
37FUFP6BDP
37GUGP6BDP
37HUGP6BDP
37IUHP6BDP
37JUHP6BDP
37LPSP6BDP
37LPUP6BDP
37CUDP2BGP
37DUDP2BGP
37EUEP2BGP
37FUFP2BGP
37GUGP2BGP
37HUGP2BGP
37IUHP2BGP
37JUHP2BGP
37LPSP2BGP
37LPUP2BGP
37MPXP2BGP
37CUDP4BHP
37DUDP4BHP
37EUEP4BHP
37FUFP4BHP
37GUGP4BHP
37HUGP4BHP
37IUHP4BHP
37JUHP4BHP
37LPSP4BHP
37LPUP4BHP
37MPXP4BHP
37CUDP5BEP
37DUDP5BEP
37EUEP5BEP
37FUFP5BEP
37GUGP5BEP
37HUGP5BEP
37IUHP5BEP
37JUHP5BEP
—
37LPUP5BEP
37MPXP5BEP

List
Price $

—

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009. Continue
to order enclosed starters with the ESP100 OLR until
then.

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Reduced Voltage Heavy Duty Starters

Wye Delta, Open Transition with Solid State Overload, Class 36 & 37
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳

Coil and Control Voltage
The coil voltage will always match the
motor voltage.
As standard, a CPT is supplied and 120V
control voltage is utilized.
To change to 120V separate control
voltage (CPT not supplied), change
the 9th character to “F”.
To change to 24VAC separate control
voltage (CPT not supplied), change the
9th character to “J”.

Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/126.
Wiring Diagrams see page 8/140.
Replacement Parts see page 8/157.
For additional enclosure options see page 8/98.

NEMA 1 General Purpose Enclosures
Non-Combination
Enclosure

Overload

Combination Fusible
Disconnect
List
Price $

Combination Circit
Breaker

Max NEMA
Hp
Size

Half
Size

Amp
Range

Frame Catalog
Size
Number

200

10
15
20
30
40
50
60
75
150
300

1
—
2
—
3
—
4
5
5
6

—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—

10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630

A1
A1
B
B
B
B
B
—
—
—

36DUE06BD
36EUE06BD
36FUF06BD
36GUG06BD
36HUG06BD
36IUH06BD
36JUH06BD
36LPS06BD
36LPU06BD
36MPX06BD

37DUE06BDD
37EUE06BDD
37FUF06BDD
37GUG06BDD
37HUG06BDD
37IUH06BDD
37JUH06BDD
37LPS06BDD
37LPU06BDD
37MPX06BDD

60A/250V
100A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
400A/250V
600A/250V
1200A/250V

37DUE06BDF
37EUE06BDF
37FUF06BDF
37GUG06BDF
37HUG06BDF
37IUH06BDF
37JUH06BDF
37LPS06BDF
37LPU06BDF
37MPX06BDF

50
100
100
125
150
250
250
400
600
1200

37DUE06BDP
37EUE06BDP
37FUF06BDP
37GUG06BDP
37HUG06BDP
37IUH06BDP
37JUH06BDP
37LPS06BDP
37LPU06BDP
37MPX06BDP

230

10
15
25
30
50
60
75
100
150
350

1
—
2
—
3
—
4
5
5
6

—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—

10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630

A1
A1
B
B
B
B
B
—
—
—

36DUE02BG
36EUE02BG
36FUF02BG
36GUG02BG
36HUG02BG
36IUH02BG
36JUH02BG
36LPS02BG
36LPU02BG
36MPX02BG

37DUE02BGD
37EUE02BGD
37FUF02BGD
37GUG02BGD
37HUG02BGD
37IUH02BGD
37JUH02BGD
37LPS02BGD
37LPU02BGD
37MPX02BGD

60A/250V
60A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
400A/250V
600A/250V
1200A/250V

37DUE02BGF
37EUE02BGF
37FUF02BGF
37GUG02BGF
37HUG02BGF
37IUH02BGF
37JUH02BGF
37LPS02BGF
37LPU02BGF
37MPX02BGF

50
50
100
100
150
250
250
400
600
1200

37DUE02BGP
37EUE02BGP
37FUF02BGP
37GUG02BGP
37HUG02BGP
37IUH02BGP
37JUH02BGP
37LPS02BGP
37LPU02BGP
37MPX02BGP

460

15
30
40
60
75
100
150
200
300
700

1
—
2
—
3
—
4
5
5
6

—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—

10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630

A1
A1
B
B
B
B
B
—
—
—

36DUD04BH
36EUE04BH
36FUF04BH
36GUG04BH
36HUG04BH
36IUH04BH
36JUH04BH
36LPS04BH
36LPU04BH
36MPX04BH

37DUD04BHD
37EUE04BHD
37FUF04BHD
37GUG04BHD
37HUG04BHD
37IUH04BHD
37JUH04BHD
37LPS04BHD
37LPU04BHD
37MPX04BHD

30A/600V
60A/600V
100A/600V
200A/600V
200A/600V
200A/600V
400A/600V
400A/600V
600A/600V
1600A/600V

37DUD04BHF
37EUE04BHF
37FUF04BHF
37GUG04BHF
37HUG04BHF
37IUH04BHF
37JUH04BHF
37LPS04BHF
37LPU04BHF
37MPX04BHF

30
50
100
100
125
150
250
400
600
1200

37DUD04BHP
37EUE04BHP
37FUF04BHP
37GUG04BHP
37HUG04BHP
37IUH04BHP
37JUH04BHP
37LPS04BHP
37LPU04BHP
37MPX04BHP

575

15
30
40
60
75
100
150
200
300
700

1
—
2
—
3
—
4
5
5
6

—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—

10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630

A1
A1
B
B
B
B
B
—
—
—

36DUD05BE
36EUE05BE
36FUF05BE
36GUG05BE
36HUG05BE
36IUK05BE
36JUH05BE
36LPS05BE
36LPU05BE
36MPX05BE

37DUD05BED
37EUE05BED
37FUF05BED
37GUG05BED
37HUG05BED
37IUK05BED
37JUH05BED
37LPS05BED
37LPU05BED
37MPX05BED

30A/600V
60A/600V
100A/600V
100A/600V
200A/600V
200A/600V
400A/600V
400A/600V
600A/600V
1600A/600V

37DUD05BEF
37EUE05BEF
37FUF05BEF
37GUG05BEF
37HUG05BEF
37IUK05BEF
37JUH05BEF
37LPS05BEF
37LPU05BEF
37MPX05BEF

30
50
50
100
125
150
250
250
400
1600

37DUD05BEP
37EUE05BEP
37FUF05BEP
37GUG05BEP
37HUG05BEP
37IUK05BEP
37JUH05BEP
37LPS05BEP
37LPU05BEP
37MPX05BEP

Siemens Industry, Inc.
Industrial Controls Catalog

Catalog
Number

Circuit
Breaker
Amps

Motor
Voltage

Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).

List
Price $

Combination Non-Fusible
Disconnect
Fuse Clip
Catalog
List
Size
Number
Price $
Amps/Volts

Catalog
Number

List
Price $

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009. Continue
to order enclosed starters with the ESP100 OLR until
then.

Product Category: NEMA

8/67

Reduced Voltage Heavy Duty Starters

Wye Delta, Closed Transition with Solid State Overload, Class 36 & 37
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳

Coil and Control Voltage
The coil voltage will always match the
motor voltage.
As standard, a CPT is supplied and 120V
control voltage is utilized.
To change to 120V separate control
voltage (CPT not supplied), change
the 9th character to “F”.
To change to 24VAC separate control
voltage (CPT not supplied), change the
9th character to “J”.

Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/126.
Wiring Diagrams see page 8/141.
Replacement Parts see page 8/157.
For additional enclosure options see page 8/98.

NEMA 1 General Purpose Enclosures
Non-Combination
Enclosure

Overload

Combination Fusible
Disconnect
List
Price $

Combination Circit
Breaker

Max NEMA
Hp
Size

Half
Size

Amp
Range

Frame Catalog
Size
Number

200

10
15
20
30
40
50
60
75
150
300

1
—
2
—
3
—
4
5
5
6

—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—

10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630

A1
A1
B
B
B
B
B
—
—
—

36DUEC6BD
36EUEC6BD
36FUFC6BD
36GUGC6BD
36HUGC6BD
36IUHC6BD
36JUHC6BD
36LPSC6BD
36LPUC6BD
36MPXC6BD

37DUEC6BDD
37EUEC6BDD
37FUFC6BDD
37GUGC6BDD
37HUGC6BDD
37IUHC6BDD
37JUHC6BDD
37LPSC6BDD
37LPUC6BDD
37MPXC6BDD

60A/250V
100A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
400A/250V
600A/250V
1200A/250V

37DUEC6BDF
37EUEC6BDF
37FUFC6BDF
37GUGC6BDF
37HUGC6BDF
37IUHC6BDF
37JUHC6BDF
37LPSC6BDF
37LPUC6BDF
37MPXC6BDF

50
100
100
125
150
250
250
400
600
1200

37DUEC6BDP
37EUEC6BDP
37FUFC6BDP
37GUGC6BDP
37HUGC6BDP
37IUHC6BDP
37JUHC6BDP
37LPSC6BDP
37LPUC6BDP
37MPXC6BDP

230

10
15
25
30
50
60
75
100
150
350

1
—
2
—
3
—
4
5
5
6

—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—

10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630

A1
A1
B
B
B
B
B
—
—
—

36DUEC2BG
36EUEC2BG
36FUFC2BG
36GUGC2BG
36HUGC2BG
36IUHC2BG
36JUHC2BG
36LPSC2BG
36LPUC2BG
36MPXC2BG

37DUEC2BGD
37EUEC2BGD
37FUFC2BGD
37GUGC2BGD
37HUGC2BGD
37IUHC2BGD
37JUHC2BGD
37LPSC2BGD
37LPUC2BGD
37MPXC2BGD

60A/250V
60A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
400A/250V
600A/250V
1200A/250V

37DUEC2BGF
37EUEC2BGF
37FUFC2BGF
37GUGC2BGF
37HUGC2BGF
37IUHC2BGF
37JUHC2BGF
37LPSC2BGF
37LPUC2BGF
37MPXC2BGF

50
50
100
100
150
250
250
400
600
1200

37DUEC2BGP
37EUEC2BGP
37FUFC2BGP
37GUGC2BGP
37HUGC2BGP
37IUHC2BGP
37JUHC2BGP
37LPSC2BGP
37LPUC2BGP
37MPXC2BGP

460

15
30
40
60
75
100
150
200
300
700

1
—
2
—
3
—
4
5
5
6

—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—

10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630

A1
A1
B
B
B
B
B
—
—
—

36DUDC4BH
36EUEC4BH
36FUFC4BH
36GUGC4BH
36HUGC4BH
36IUHC4BH
36JUHC4BH
36LPSC4BH
36LPUC4BH
36MPXC4BH

37DUDC4BHD
37EUEC4BHD
37FUFC4BHD
37GUGC4BHD
37HUGC4BHD
37IUHC4BHD
37JUHC4BHD
37LPSC4BHD
37LPUC4BHD
37MPXC4BHD

30A/600V
60A/600V
100A/600V
200A/600V
200A/600V
200A/600V
400A/600V
400A/600V
600A/600V
1600A/600V

37DUDC4BHF
37EUEC4BHF
37FUFC4BHF
37GUGC4BHF
37HUGC4BHF
37IUHC4BHF
37JUHC4BHF
37LPSC4BHF
37LPUC4BHF
37MPXC4BHF

30
50
100
100
125
150
250
400
600
1200

37DUDC4BHP
37EUEC4BHP
37FUFC4BHP
37GUGC4BHP
37HUGC4BHP
37IUHC4BHP
37JUHC4BHP
37LPSC4BHP
37LPUC4BHP
37MPXC4BHP

575

15
30
40
60
75
100
150
200
300
700

1
—
2
—
3
—
4
5
5
6

—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—

10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630

A1
A1
B
B
B
B
B
—
—
—

36DUDC5BE
36EUEC5BE
36FUFC5BE
36GUGC5BE
36HUGC5BE
36IUKC5BE
36JUHC5BE
36LPSC5BE
36LPUC5BE
37MPXC5BF

37DUDC5BED
37EUEC5BED
37FUFC5BED
37GUGC5BED
37HUGC5BED
37IUKC5BED
37JUHC5BED
37LPSC5BED
37LPUC5BED
37MPXC5BED

30A/600V
60A/600V
100A/600V
100A/600V
200A/600V
200A/600V
400A/600V
400A/600V
600A/600V
1600A/600V

37DUDC5BEF
37EUEC5BEF
37FUFC5BEF
37GUGC5BEF
37HUGC5BEF
37IUKC5BEF
37JUHC5BEF
37LPSC5BEF
37LPUC5BEF
37MPXC5BEF

30
50
50
100
125
150
250
250
400
1600

37DUDC5BEP
37EUEC5BEP
37FUFC5BEP
37GUGC5BEP
37HUGC5BEP
37IUKC5BEP
37JUHC5BEP
37LPSC5BEP
37LPUC5BEP
37MPXC5BEP

8/68

Catalog
Number

Circuit
Breaker
Amps

Motor
Voltage

Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).

List
Price $

Combination Non-Fusible
Disconnect
Fuse Clip
Catalog
List
Size
Number
Price $
Amps/Volts

Catalog
Number

List
Price $

 Enclosed

starters with the ESP200 OLR will not be
available until approximately December 2009. Continue
to order enclosed starters with the ESP100 OLR until
then.

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Lighting and Heating Control

Electrically Held Lighting Contactors
General

Features

Application

▪
▪
▪
▪
▪
▪
▪

Siemens electrically held lighting
contactors provide a safe, convenient
means of local or remote switching
for tungsten and ballast lamp loads,
mercury arc lamps, and 3-phase
resistive heating.

Compact Design
Silver Cadmium Oxide Contacts
Pressure Type Terminals
Straight Thru Wiring
Wide Variety of Contact Configurations
12-Poles Maximum
Available From 20 Amps–400 Amps
Up to 12-Poles 20, 30 and 60 Amps
3-Poles On 100–400 Amps

▪ Full Line of Enclosures
NEMA 1
NEMA 3R/12
NEMA 4/4X (Stainless Steel)
▪ Available In Combination Form with
Choice of:
Fusible Disconnect
Non-Fusible Disconnect
Circuit Breaker
All
Combination Lighting Contactors
▪
are UL Service Entrance Listed
▪ Full Line of Factory And Field
Modifications
▪ UL Listed Files #E27683
▪ CSA Certified File LR 6535

Siemens Industry, Inc.
Industrial Controls Catalog

Class LE electrically held lighting
and heating contactors are used in
applications where it is not critical that
the contacts remain in the closed
position during loss of control power.
These lighting contactors are rated at
480V Tungsten, 600V Ballast. They are
available in 2–12 poles with a variety of
NO and NC contact arrangements.
Typical applications include:

▪ Industrial and Commercial Buildings
▪ Stadiums
▪ Airports
▪ Non-Critical Resistive Heaters and
other Non-Inductive Loads

8/69

Lighting and Heating Control

Electrically Held Lighting Contactors, Class LE
Selection
Ordering Information

Coil Table

Replace the *** with a number from the coil table.
Field modifications see page 8/82.
왘 Factory modification kits see page 8/95.
왘 Dimensions see page 8/111 open page 8/129 enclosed.
왘 Wiring Diagrams see page 8/146.
왘 Replacement parts see page 8/160.

60Hz Voltage

Number

24
120
208
240
277
480
600

024
120
208
240
277
480
600

왘
왘

Open and Non-combination Enclosed Contactors
Open Type

NEMA 1

NEMA 12
NEMA 3/3R 

General Purpose

Max.
Amp
Rating

Number
of
Poles

2
3

4

6
20

8

9

10

12

30

60
100
200
300
400

3
6
9
12
3
6
9
12
3
3
3
3

Industrial Use
Weatherproof

Normally
Closed
Contacts

Normally
Open
Contacts

Catalog Number

2
0
3
0
4
2
1
0
2
0
4
2
0
4
2
0
4
2
0
4
2
0
0
0
0
0
0
0
0
0
0
0
0
0

0
2
0
3
0
2
3
4
4
6
4
6
8
5
7
9
6
8
10
8
10
12
3
6
9
12
3
6
9
12
3
3
3
3

LEN00B200***A
LEN00B002***A
LEN00B300***A
LEN00B003***A
LEN00B400***A
LEN00B202***A
LEN00B103***A
LEN00B004***A
LEN00B204***A
LEN00B006***A
LEN00B404***A
LEN00B206***A
LEN00B008***A
LEN00B405***A
LEN00B207***A
LEN00B009***A
LEN00B406***A
LEN00B208***A
LEN00B010***A
LEN00B408***A
LEN00B210***A
LEN00B012***A
LEN00C003***A
LEN00C006***A
LEN00C009***A
LEN00C012***A
LEN00D003***A
LEN00D006***A
LEN00D009***A
LEN00D012***A
LEN00E003***A
LEN00F003***A
LEN00G003***A
LEN00H003***A

List Price $

Catalog Number

List Price $

LEN01B200***A
LEN01B002***A
LEN01B300***A
LEN01B003***A
LEN01B400***A
LEN01B202***A
LEN01B103***A
LEN01B004***A
LEN01B204***A
LEN01B006***A
LEN01B404***A
LEN01B206***A
LEN01B008***A
LEN01B405***A
LEN01B207***A
LEN01B009***A
LEN01B406***A
LEN01B208***A
LEN01B010***A
LEN01B408***A
LEN01B210***A
LEN01B012***A
LEN01C003***A
LEN01C006***A
LEN01C009***A
LEN01C012***A
LEN01D003***A
LEN01D006***A
LEN01D009***A
LEN01D012***A
LEN01E003***A
LEN01F003***A
LEN01G003***A
LEN01H003***A

NEMA 4/4X Stainless Steel
Watertight, Dust-tight,
Corrosion Resistant,
304 Stainless Steel

Catalog Number

List Price $ Catalog Number

LEN02B200***A
LEN02B002***A
LEN02B300***A
LEN02B003***A
LEN02B400***A
LEN02B202***A
LEN02B103***A
LEN02B004***A
LEN02B204***A
LEN02B006***A
LEN02B404***A
LEN02B206***A
LEN02B008***A
LEN02B405***A
LEN02B207***A
LEN02B009***A
LEN02B406***A
LEN02B208***A
LEN02B010***A
LEN02B408***A
LEN02B210***A
LEN02B012***A
LEN02C003***A
LEN02C006***A
LEN02C009***A
LEN02C012***A
LEN02D003***A
LEN02D006***A
LEN02D009***A
LEN02D012***A
LEN02E003***A
LEN02F003***A
LEN02G003***A
LEN02H003***A

LEN04B200***A
LEN04B002***A
LEN04B300***A
LEN04B003***A
LEN04B400***A
LEN04B202***A
LEN04B103***A
LEN04B004***A
LEN04B204***A
LEN04B006***A
LEN04B404***A
LEN04B206***A
LEN04B008***A
LEN04B405***A
LEN04B207***A
LEN04B009***A
LEN04B406***A
LEN04B208***A
LEN04B010***A
LEN04B408***A
LEN04B210***A
LEN04B012***A
LEN04C003***A
LEN04C006***A
LEN04C009***A
LEN04C012***A
LEN04D003***A
LEN04D006***A
LEN04D009***A
LEN04D012***A
LEN04E003***A
LEN04F003***A
LEN04G003***A
LEN04H003***A

List Price $

 For

conduit hubs and conversion instructions, see page
8/88.
be field assembled. Order mounting kit
49MCMPMA and required number of contactors.
Example, 3, three pole contactors and 1 mounting plate
for a 9-pole open assembly.

 Can

8/70

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Lighting and Heating Control

Combination Electrically Held Lighting Contactors, Class LE
Selection
Ordering Information

Coil Table

Replace the *** with a number from the coil table.
Field modification kits see page 8/82.
왘 Factory modifications see page 8/95.
왘 Dimensions see page 8/129.
왘 Wiring Diagrams see page 8/146.
왘 Replacement parts see page 8/160.
왘
왘

60Hz Voltage

Number

24
120
208
240
277
480
600

024
120
208
240
277
480
600

Combination Lighting Contactors
NEMA 12, NEMA 3/3R 
NEMA 4 Painted (thru 100 amps)

NEMA 1
General Purpose

Disconnect
Type

Non-Fusible

Max.
Amp
Rating

20
30
60
100
200
300
20
30
60

Fusible
100
200
300
Circuit
Breaker

20
30
60
100

Number
of NO
Poles

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Disc
Amp
Rating

Disc Amp/ Circuit
Fuse Clip Breaker
Rating
Rating

Catalog Number

30A
30A
60A
100A
200A
400A
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
30A/250V
30A/600V
30A/250V
30A/600V
60A/250V
60A/600V
100A/250V
100A/600V
200A/250V
200A/600V
400A/250V
400A/600V
—
—
—
—

LEDB1B003***A
LEDB1C003***A
LEDD1D003***A
LEDF1E003***A
LEDH1F003***A
LEDK1G003***A
LEFA1B003***A
LEFB1B003***A
LEFA1C003***A
LEFB1C003***A
LEFC1D003***A
LEFD1D003***A
LEFE1E003***A
LEFF1E003***A
LEFG1F003***A
LEFH1F003***A
LEFJ1G003***A
LEFK1G003***A
LEBT1B003***A
LEBV1C003***A
LEBY1D003***A
LEBZ1E003***A

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
20A
30A
60A
100A

List Price $

NEMA 4/4X Stainless Steel 

Industrial Use
Weatherproof, Watertight, Dust-tight

Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel

Catalog Number

Catalog Number

LEDB2B003***A
LEDB2C003***A
LEDD2D003***A
LEDF2E003***A
LEDH2F003***A
LEDK2G003***A
LEFA2B003***A
LEFB2B003***A
LEFA2C003***A
LEFB2C003***A
LEFC2D003***A
LEFD2D003***A
LEFE2E003***A
LEFF2E003***A
LEFG2F003***A
LEFH2F003***A
LEFJ2G003***A
LEFK2G003***A
LEBT2B003***A
LEBV2C003***A
LEBY2D003***A
LEBY2D003***A

List Price $

List Price $

LEDB4B003***A
LEDB4C003***A
LEDD4D003***A
LEDF4E003***A
LEDH4F003***A
LEDK4G003***A
LEFA4B003***A
LEFB4B003***A
LEFA4C003***A
LEFB4C003***A
LEFC4D003***A
LEFD4D003***A
LEFE4E003***A
LEFF4E003***A
LEFG4F003***A
LEFH4F003***A
LEFJ4G003***A
LEFK4G003***A
LEBT4B003***A
LEBV4C003***A
LEBY4D003***A
LEBZ4E003***A

 For

conduit hubs and conversion instructions, see page
8/88.

Siemens Industry, Inc.
Industrial Controls Catalog

Product Category: NEMA

8/71

Lighting and Heating Contactors

Mechanically and Magnetically Held Lighting Contactors
Selection

CLM 20 Amp

CLM 100 Amp

Mechanically Latched Lighting
and Heating Contactor
The CLM Lighting Contactors can be
used with metal halide, mercury vapor,
quartz halogen, tungsten and fluorescent lighting. They provide reliable and
convenient lighting control in numerous
applications, such as industrial plants,
schools, hospitals, office buildings,
shopping centers, airports, stadiums . . .
literally everywhere lighting is required.
The CLMs are listed under UL 508 with
no derating when used open or
enclosed. Combination lighting
contactors are listed for UL service
entrance.
UL listed File #E60310
CSA Certified File LR 6535
Type CLM 20 Amp Lighting
Contactor Solid State Control
Modules
The CLM 20 amp lighting contactor
is an electromagnetically operated,
mechanically latched three wire control
contactor. The most commonly used
method of control is a three position
momentary contact switch with a
center-off position. The controlling
device must be able to make the coil
inrush current but need not break it.
The coil current is interrupted by the
control contacts within the CLM
contactor. Power for the control line may
come from a separate source or directly
from the line side of the CLM contactor.
The CLM contactor can also be
controlled by devices such as:
▪ Break-glass control stations
▪ Timers having single pole, double
throw contacts
▪ Photo-electric cells
▪ Energy management systems
▪ Microprocessors
▪ Occupancy sensors
Control modules make it possible to
use a controlling device that does not
have enough current-carrying capacity
to control the CLM contactor directly.
Control modules are also used when

 Operation

8/72

the control station is to be located at
a distance greater than the allowable
contactor line run.
Another use for control modules occurs
when the controlling device is only
available as a single pole single-throw
contact necessitating a two wire
control line.
Still another application for control
modules is when start-stop three
wire control is needed.
Control modules also can make it
possible to operate the CLM coil from
its own incoming line at one voltage
while providing the control at a
second, perhaps lower voltage.

Two Wire Control Module
(Accessory 47)
The advantages of two wire controls are:
1. Control station can have lower
ampacity rating.
2. Control station can be located an
extended distance from the CLM
contactor.
3. Control module can frequently be
controlled directly from
microprocessor.
4. Control devices can be two wire
single pole, single-throw types.
5. Control voltage may be different than
the CLM coil circuit and at a lower
voltage level.
Note: If the control power to the solid
state control module is lost while the
module is energized the lighting
contactor will open. If the line power
to the lighting contactor is lost while the
contactor is energized the contactor will
not change state with return of line
voltage. Power will be restored to
the load if the control module is still
energized. Control station should
be the maintained type.
Three Wire Control Module
(Accessory 48)
1. The accessory 48 consists of two
relays with contacts appropriately
interconnected which provides for an
interlocking that prevents both relays
from being energized simultaneously.
2. This module has similar characteristics
to the two wire module (Accessory 47)
except there is no change of switch
contact position upon loss of control line
power. Control stations should be the
momentary type.

Stop-Start Control Module
(Accessory 49)
Stop-start three wire maintained control
is an arrangement used mostly when
controlling motors, but can be used in
lighting applications.
Any number of momentary contact
control stations consisting of normally
open start buttons and normally closed
stop buttons can be used. Start buttons
are connected in parallel and stop
buttons in series.
Operation (Magnetic Latch)
A permanent magnet is built into the
contactor structure of the 30A, 60A,
100A, and 200A contactors that will
maintain the contactor in its energized
state indefinitely without using control
power. When energized, a DC current is
applied that produces a magnetic field
that reinforces the polarity of the
permanent magnet, and the contactor
pulls in immediately. The current to the
coil is disconnected by the coil clearing
interlock. In order to drop out the
contactor, it is necessary to apply a field
through the OFF coil in the reverse
direction to the permanent magnet.
This momentarily cancels the magnetic
attraction and the contactor drops out.
Coil and module failures are possible
when used with solid state relays and
PLC outputs. 24-volt systems are ok to
use, but 120 volts and above should be
discouraged. If higher values cannot
be avoided, an interposing relay should
be used.

(Mechanically Latched)
The 300 & 400A lighting and heating
contactors operate using a latching
mechanism.
Closing – When the “close” pushbutton
is operated, the closing coil is energized,
closing the contactor. As the contactor
closes, the latch lever hooks over the
latch pin to mechanically latch the
contactor closed. The coil-clearing
auxiliary contact de-energizes the
closing coil.
Opening – When the “Trip” pushbutton
is operated, the trip solenoid coil is
energized, unhooking the latch lever
from the latch pin, which allows the
contactor to open. As the contactor
opens, the coil-clearing auxiliary contact
de-energizes the trip solenoid coil.

through control modules.

Siemens Industry, Inc.
Industrial Controls Catalog

Lighting Control

Mechanically and Magnetically Held Lighting Contactors, Class CLM
Selection
Ordering Information
왘
왘
왘
왘
왘
왘

Coil Table

Replace *** with a number from the coil table.
Field modification kits see page 8/82.
Factory modifications see page 8/95.
Dimensions see page 8/112 open page 8/129 enclosed.
Wiring Diagrams see page 8/147.
Replacement parts see page 8/160.

60Hz Voltage

Number

24 
120
208
240
277
480
600

024
120
208
240
277
480
600

Open and Non-combination Enclosed Contactors
Open Type

Enclosure
NEMA 1

Max
Amp
Rating

20

30

60

100

200

300
400

NEMA 4/4X Stainless Steel

NEMA 12

NEMA 3/3R

General Purpose

Watertight, Dust-tight,
Corrosion Resistant,
304 Stainless Steel

Industrial Use
Weatherproof

Number
of Poles
2
3
4
6
8
10
12
2
3
4
5
6
8
9
10
12
2
3
4
5
6
8
9
10
12
2
3
4
5
2
3
4
5
2
3
2
3

Catalog Number

see table
below

CLM0C02***
CLM0C03***
CLM0C04***
CLM0C05***
CLM0C06***
CLM0C08***
CLM0C09***
CLM0C10***
CLM0C12***
CLM0D02***
CLM0D03***
CLM0D04***
CLM0D05***
CLM0D06***
CLM0D08***
CLM0D09***
CLM0D10***
CLM0D12***
CLM0E02***
CLM0E03***
CLM0E04***
CLM0E05***
CLM0F02***
CLM0F03***
CLM0F04***
CLM0F05***
CLM0G02***
CLM0G03***
CLM0H02***
CLM0H03***

List Price $ Catalog Number
CLM1B02***
CLM1B03***
CLM1B04***
CLM1B06***
CLM1B08***
CLM1B10***
CLM1B12***
CLM1C02***
CLM1C03***
CLM1C03***
CLM1C05***
CLM1C06***
CLM1C08***
CLM1C09***
CLM1C10***
CLM1C12***
CLM1D02***
CLM1D03***
CLM1D04***
CLM1D05***
CLM1D06***
CLM1D08***
CLM1D09***
CLM1D10***
CLM1D12***
CLM1E02***
CLM1E03***
CLM1E04***
CLM1E05***
CLM1F02***
CLM1F03***
CLM1F04***
CLM1F05***
CLM1G02***
CLM1G03***
CLM1H02***
CLM1H03***

List Price $

Catalog Number
CLM2B02***
CLM2B03***
CLM2B04***
CLM2B06***
CLM2B08***
CLM2B10***
CLM2B12***
CLM2C02***
CLM2C03***
CLM2C04***
CLM2C05***
CLM2C06***
CLM2C08***
CLM2C09***
CLM2C10***
CLM2C12***
CLM2D02***
CLM2D03***
CLM2D04***
CLM2D05***
CLM2D06***
CLM2D08***
CLM2D09***
CLM2D10***
CLM2D12***
CLM2E02***
CLM2E03***
CLM2E04***
CLM2E05***
CLM2F02***
CLM2F03***
CLM2F04***
CLM2F05***
CLM2G02***
CLM2G03***
CLM2H02***
CLM2H03***

List Price $

Catalog Number
CLMSB02***
CLMSB03***
CLMSB04***
CLMSB06***
CLMSB08***
CLMSB10***
CLMSB12***
CLMSC02***
CLMSC03***
CLMSC04***
CLMSC05***
—
—
—
—
—
CLMSD02***
CLMSD03***
CLMSD04***
CLMSD05***
—
—
—
—
—
CLMSE02***
CLMSE03***
CLMSE04***
CLMSE05***
CLMSF02***
CLMSF03***
CLMSF04***
CLMSF05***
—
—
—
—

List Price $

—
—
—
—
—

—
—
—
—
—

—
—
—
—

Open 20 Amp Contactors
Max
Amp
Rating

20

110–120V Coil 50/60Hz
Number
of Poles

Catalog Number

2
3
4
6
8
10
12

CLM22031
CLM32031
CLM42031
CLM62031
CLM82031
CLM102031
CLM122031

 Contactors

208–240V Coil 50/60Hz
List Price $ Catalog Number

with 2–6-poles will be assembled with all
poles located in the top portion of the contactor.
Contactors with 8–12-poles will be assembled with 6poles in the top portion and the remaining poles in
the bottom portion of the contactor.

Siemens Industry, Inc.
Industrial Controls Catalog

265–277V Coil 50/60Hz
List Price $ Catalog Number

CLM22061
CLM32061
CLM42061
CLM62061
CLM82061
CLM102061
CLM122061
 24

List Price $ Catalog Number

CLM22071
CLM32071
CLM42071
CLM62071
CLM82071
CLM102071
CLM122071

volt coils are not available on 20, 300 and 400 amp
contactor sizes. For 24 volt control of 20 amp contactor
select solid state control module.
 For conduit hubs and conversion instructions, see
page 8/88.

Product Category: NEMA

440–480V Coil 50/60Hz
List Price $

CLM22091
CLM32091
CLM42091
CLM62091
CLM82091
CLM102091
CLM122091
 CLM

30 & 60A 6-12-pole can be field assembled.
Order mounting kit 49MCMPMA and the appropriate
number of 2-5 pole contactors.
 600 volt coils are not available on 20 amp
contactors.

8/73

Lighting Control

Combination Mechanically and Magnetically Held Lighting Contactors, Class CLM
Selection
Ordering Information
왘
왘
왘
왘
왘
왘

Coil Table

Replace *** with a number from the coil table.
Field modification kits see page 8/82.
Factory modifications see page 8/95.
Dimensions see page 8/129.
Wiring Diagrams see page 8/147.
Replacement parts see page 8/160.

60Hz Voltage

Number

24 
120
208
240
277
480
600

024
120
208
240
277
480
600

Combination Lighting Contactors
Enclosure
NEMA 12, NEMA 3/3R 
NEMA 4 Painted (thru 100 amps)

NEMA 1
General Purpose

Disconnect
Type

Non-Fusible

Contactor
Amp
Rating

Number
of NO
Poles

20
30
60
100
200
300

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

20
30
60
Fusible
100
200
300
20
30
60
100
200
300

Circuit
Breaker

Disc
Amp
Rating

Disc Amp/
Fuse Clip
Rating

30A
30A
60A
100A
200A
400A
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
30A/250V
30A/600V
30A/250V
30A/600V
60A/250V
60A/600V
100A/250V
100A/600V
200A/250V
200A/600V
400A/250V
400A/600V
—
—
—
—
—
—

Circuit
Breaker
Rating Catalog Number List Price $

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
20A
30A
60A
100A
200A
300A

CMNB14***
CMNC14***
CMND15***
CMNE16***
CMNF17***
CMNG18***
CMFB10***
CMFB11***
CMFC10***
CMFC11***
CMFD12***
CMFD13***
CMFE14***
CMFE15***
CMFF16***
CMFF17***
CMFG18***
CMFG19***
CMBB14***
CMBC15***
CMBD18***
CMBE18***
CMBF10***
CMBG11***

NEMA 4/4X Stainless Steel

Industrial Use
Weatherproof, Watertight, Dust-tight

Watertight, Dust-tight,
Corrosion Resistant,
304 Stainless Steel

Catalog Number

Catalog Number

List Price $

CMNB24***
CMNC24***
CMND25***
CMNE26***
CMNF27***
CMNG28***
CMFB20***
CMFB21***
CMFC20***
CMFC21***
CMFD22***
CMFD23***
CMFE24***
CMFE25***
CMFF26***
CMFF27***
CMFG28***
CMFG29***
CMBB24***
CMBC25***
CMBD28***
CMBE28***
CMBF20***
CMBG21***

List Price $

CMNBS4***
CMNCS4***
CMNDS5***
CMNES6***
CMNFS7***
CMNGS8***
CMFBS0***
CMFBS1***
CMFCS0***
CMFCS1***
CMFDS2***
CMFDS3***
CMFES4***
CMFES5***
CMFFS6***
CMFFS7***
CMFGS8***
CMFGS9***
CMBBS4***
CMBCS5***
CMBDS8***
CMBES8***
CMBFS0***
CMBGS1***

Lighting & Heating Contactor Ratings CLM
Maximum AC/DC Voltage and
Amp Ratings
Load
Type

Poles to Load
Amperes
2 for 1-Phase
Continuous 1 for 1-Phase 3 for 3-Phase

Tungsten
Ballast
General
General

20
20
30
20

250V AC
347V AC
347V AC
125V DC

250V AC
600V AC
600V AC
250V DC

Contactor Ratings
Load
Amperes
Max Volts
Type
Continuous Line to Line

Tungsten
Ballast
Heating

30-400
30-400
30-400

Max Volts
Line to Neutral

480
600
600

277
346
346

Inrush Current Over Fuse Size (amps RMS)
at AC Control Voltage 20A CLM
Amps
Inrush
Fuse

 24

120V
5.0
2.0

240V
2.5
1.0

277V
2.2
1.0

347V
1.8
0.75

Inrush VA

Dropout VA

20
30
60
60
100/200
100/200
300/400

625
410
410
600
900
1300
1600

6
40
40
40
200
130
550

2-12
2-5
2-3
4-5
2-3
4-5
2-3

480V
1.3
0.5

volt coils are not available on 20 and 300 amp
contactors. Use solid state control module on 20 amp
size.

8/74

AC Coil Data
Contactor
Amperes
No. Poles

 For

conduit hubs and conversion instructions, see
page 8/88.

Product Category: NEMA

 600

volt coils are not available on 20 amp
contactors.

Siemens Industry, Inc.
Industrial Controls Catalog

Industrial Control Power Transformers

Class MT
General

Features
▪ Epoxy-encapsulated (50–5000VA);
Completely seals the transformer coils
against moisture, dust, dirt and
industrial contaminants for maximum
protection in hostile and industrial
environments
▪ Fuse clips (most models). Factory
mounted for integral fusing on the
secondary side to save panel space,
save wiring time and save the cost
of buying an add-on fuse block or kit
▪ Integrally molded barriers. Between
terminals and transformer, protect
against electrical creepage. Up to 30%
greater terminal contact area permits
low-loss connections. Extra-deep barriers reduce the chance of shorts from
frayed leads or careless wiring
▪ Terminals. Molded into the
transformer, are difficult to break during wiring. A full quarter-inch of
thread on the 10-32 terminal screws
prevents stripping and pullout
▪ Jumpers supplied. Two jumper links
are standard with all transformers
which can be wired for dual primary
voltages
Operation
Industrial control circuits and motor
control loads typically require more
current when they are initially energized
than under normal operating conditions.
This period of high current demand,
referred to as inrush, may be as great
as ten times the current required under
steady state (normal) operating
conditions, and can last up to 40
milliseconds. A transformer in a circuit
subject to inrush will typically attempt
to provide the load with the required
current during the inrush period.
However, it will be at
the expense of the secondary voltage
stability by allowing the voltage to
the load to decrease as the current
increases. This period of secondary
voltage instability, resulting from
increased current, can be of such
magnitude that the transformer is
unable to supply sufficient voltage to
energize the load. The transformer
must therefore be designed and
constructed to accommodate the high
inrush current, while maintaining
secondary voltage stability. According
to NEMA standards, the secondary
voltage would typically be
at 85% of the rated voltage.

Siemens Industry, Inc.
Industrial Controls Catalog

Industrial Control Power Transformers
are specifically designed and built to
provide adequate voltage to the load
while accommodating the high current
levels present at inrush. These
transformers deliver excellent
secondary voltage regulation and meet
or exceed the standards established
by NEMA, ANSI, UL and CSA. Their
rugged construction and excellent
electrical characteristics ensure reliable
operation of electromagnetic devices
and trouble-free performance.

Specifications
▪ Laminations are built with silicon
steel to minimize core losses and
to increase optimum performance
and efficiency
▪ Copper magnet wire of the highest
quality assures efficient operation
▪ Factory mounted type “K” fuse
clips are standard on all secondary
transformers where possible
▪ Two jumper links are standard with
all transformers which can be wired
for dual primary voltages
▪ UL listed and CSA certified
▪ 50/60 Hz rated
▪ Insulation materials are of the
highest rating available for the
temperature class

▪ Mounting brackets are heavy
gauge steel to add strength to core
construction and provide stable
mounting. Slotted mounting feet
permit easy installation
▪ Attractive black finish; easy-to-read
nameplate with complete rating data
and wiring diagram
▪ Class 105°C (221°F) insulation
system. 55°C (131°F) temperature
rise. (50 – 750VA typical)
▪ Class 180°C (356°F) insulation
system. 120°C (248°F) temperature
rise. (1000 – 5000VA typical)
▪ Optional field mounted 2-pole
primary Class CC fuse block is
available

8/75

Industrial Control Power Transformers

Class MTG
General

the covers prevent contact with current carrying parts on
the transformer and are available for 4 terminal configurations.
The international fuse block kits have inherent touch
safe terminals and fuse clips.

Siemens Meets International Standards
CSA (Canadian Standards Association) was utilized as a
Competent Body in reviewing, interpreting and properly
complying with the requirements of IEC-742 to place a CE
mark on its MTG Series product. As a National Certification
Body, CSA also has the proper documentation and reports
on file for MTG Series to utilize the CB Scheme ensuring
acceptance throughout the world.
The standard Siemens MTG product is available with terminal
covers which meets the requirements of IEC-529, IP20
degree of protection and meets the applicable requirements
for covers per IEC-742.

Features
▪ Class MTG Industrial Control Transformers are 100%
certified for all domestic and International Applications
▪ The MTG line has full compliance with IEC Safety
standards EN 61 558
▪ CE Mark in accordance with requirements for EN 61 558
▪ Meets IP-20 specifications per IEC 529 for finger-safe
protection when used with Siemens Touch Safe snap
on terminal cover kits. Meets IP-00 specifications when
covers are not used.
▪ UL Listed (File # E46323)
▪ CSA Certified (File #LR27533)
▪ Exceeds applicable requirements for control transformers as
determined by NEMA and ANSI
▪ Insulation requirements is twice that of UL506
▪ Proven Epoxy-encapsulated coils operate cooler and
completely seal the transformer coils against moisture,
dust, dirt and industrial contaminants for maximum
protection in hostile and industrial environments
▪ Available in 50 to 750 VA sizes, in all standard voltage
combinations
▪ Class 105°C (221°F) insulation system. 55°C (131°F)
temperature rise. (50 –750VA typical)
▪ Class 180°C (356°F) insulation system. 120°C (248°F)
temperature rise. (1000–5000VA typical)
▪ Primary and secondary fusing capability available as field
installed kits for domestic or international fusing
▪ Integrally-molded terminals and barriers between terminals
make breakage virtually impossible during wiring. The MTG
transformer construction is the same as our high quality
Class MT transformers
Optional Field Installed Fuse Clip Kits For Panel Mounting
▪ 2-Pole primary Class CC fuse block
13
1
▪ 1-Pole secondary midget fuse block for ⁄32 ҂ 1 ⁄2 fuses
▪ 2-Pole primary international type fuse blocks
▪ 1-Pole secondary international type fuse blocks
Optional Touch-Safe Snap-On Terminal Cover Kits
The Touch-Safe terminal covers are designed to comply
with IEC 742 and IP 20 requirements. When installed,

8/76

IEC-742
The requirements for industrial control circuit transformers
to be used in the European Common Market are identified
by the International Electrotechnical Commission (IEC) and
specified under IEC-742, Non-Short Circuit Proof Isolating
Transformers, under the Low Voltage Directive 73/23/EEC.
Manufacturers of control transformers indicate compliance
with these requirements by placing a CE mark on the
product.
▪ Winding to winding insulation requirements may be twice
that for IEC-742 compared to UL506
▪ The electrical clearances between current carrying parts
are one-third greater to comply with IEC-742 requirements
for units up to 250VA with voltages up to 440 volts ac
▪ Transformers manufactured to IEC-742 requirements
will have a minimum of 10% higher overload capacity
than those manufactured only to UL506 requirements
While no requirement exists in IEC-742 for the electrical
connections to be either finger safe or touch proof, the
specification does state that IF a transformer is supplied
with a cover to prevent incidental contact with current
carrying parts, that cover must utilize two separate methods
or places of securing it to the component, with neither being
dependent upon the other. Additionally, one of these methods
MUST require a tool to remove it.
IEC-529
The requirements for finger-safe or touch-proof electrical
connections are identified by the International Electrotechnical
Commission (IEC) under specification 529, Classification of
Degrees of Protection Provided by Enclosures. These various
degrees of protection are identified and differentiated by IP
ratings.
The IP specification which most closely approximates
protection to a human finger is IP20. This IP rating would
be the most common degree of touch-proof connection
for electrical components such as transformers.

EN 61 558
The requirements for industrial control transformers to be
used in the European Common Market are identified
by the IEC and specified in EN 61 558, Safety of Power
Control Transformers, under Low Voltage Directive 73/23/EEC.
CE mark on the product indicates compliance.

Siemens Industry, Inc.
Industrial Controls Catalog

Industrial Control Power Transformers

Class MT, MTG
General

Transformer Selection Process
Selecting a transformer for industrial
control circuit applications requires
knowledge of the following terms:

Inrush VA is the product of load voltage (V) multiplied by the current (A) that
is required during circuit start-up. It
is calculated by adding the inrush VA
requirements of all devices (contactors,
timers, relays, pilot lights, solenoids,
etc.), which will be energized together.
Inrush VA requirements are best
obtained from the component
manufacturer.
Sealed VA is the product of load
voltage (V) multiplied by the current (A)
that is required to operate the circuit
after initial start-up or under normal
operating conditions. It is calculated by
adding the sealed VA requirements of
all electrical components of the circuit
that will be energized at any given
time. Sealed VA requirements are
best obtained from the component
manufacturer. Sealed VA is also referred
to as steady state VA.
Primary Voltage is the voltage available from the electrical distribution system and its operational frequency,
which is connected to the transformer
supply voltage terminals.
Secondary Voltage is the voltage
required for load operation which is
connected to the transformer load
voltage terminals.

Once the circuit variables have been determined, transformer selection is a simple
5-step process as follows:

1. Determine the Application Inrush VA by using the following industry accepted formula:
——————————–
Application Inrush VA = √(Inrush VA)2 ѿ (Sealed VA)2
2. Refer to the Regulation Data Chart. If the primary voltage is basically stable and
does not vary by more than 5% from nominal, the 90% secondary voltage column
should be used. If the primary voltage varies between 5% and 10% of nominal,
the 95% secondary voltage column should be used.
3. After determining the proper secondary voltage column, read down until a value
equal to or greater than the Application Inrush VA is found. In no case should a
figure less than the Application Inrush VA be used.
4. Read left to the Transformer VA Rating column to determine the proper
transformer for this application. As a final check, make sure that the Transformer
VA Rating is equal to or greater than the total sealed requirements. If not, select
a transformer with a VA rating equal to or greater than the total sealed VA.
5. Refer to the following pages to determine the proper catalog number based
on the transformer VA, and primary and secondary voltage requirements.
Regulation Data Chart

Transformer
VA Ratings

Inrush VA At 20% Power Factor
NEMA/IEC
NEMA/IEC
95% Sec
90% Sec
Voltage
Voltage

NEMA/IEC
85% Sec
Voltage

25
50
75
100
150
200
250
300
350
500
750
1000
1000
1500
2000
3000
5000

100/–––
170/190
310/350
370/410
780/860
810/900
1400/1540
1900/2090
3100/3410
4000/4400
8300/9130
15000/–––
9000/–––
10500/–––
17000/–––
24000/–––
55000/–––

150/–––
240/270
540/600
730/810
1150/1270
1450/1600
2300/2530
3850/4240
4800/5280
7000/7700
14000/15400
27000/–––
18500/–––
205000/–––
34000/–––
47500/–––
115000/–––

130/–––
200/220
410/460
540/600
930/1030
1150/1270
1900/2090
2700/2970
3650/4020
5300/5830
11000/12100
21000/–––
13000/–––
15000/–––
25500/–––
36000/–––
92500/–––

To comply with NEMA standards, which require all magnetic devices to operate successfully at 85% of rated voltage, the
90% secondary voltage column is most often used in selecting a transformer.
 For
 For

units with Class 105°C insulation systems.
units with Class 180°C insulation systems.

Fuse Clip Kit KCCFPX2R

Primary Fuse Kit
In addition to factory installed secondary fusing, Siemens offers a primary
fuse kit for class MT transformers size
50–750 VA for field installation. The
primary fuse kit includes a 2-pole Class
CC fuse block, instructions and all
associated mounting and wiring
hardware. Additionally, this fuse kit
will fit most competitors’ units. To
order this kit, use catalog number
KCCFPX2R. The primary fuse kit,
when installed, will add a maximum of
0.69 in. (18 mm) to the transformer “A”
dimension and 1.94 in. (49 mm) to the
“C” dimension.

Siemens Industry, Inc.
Industrial Controls Catalog

Primary Fuse Kit Installation—Class MT Transformer with Primary Fuse Kit, KCCFPX2R

8/77

Industrial Control Power Transformers

Domestic, Class MT
Selection

Ordering Information
왘

왘
왘
왘

Voltage Table

Use the Voltage Table to determine the
primary and secondary voltage required.
Field Modifications see page 8/90.
Dimensions see page 8/114.
Wiring Diagrams see page 8/149.

Primary Volts 50/60 Hz

Secondary Volts

240 X 480, 230 X 460, 220 X 440
240 X 480
120 X 240
115 X 230
550/575/600
208/277
208/230/460
230/460/575
380/400/415
208/230/460, 200/220/440,240/480
240/416/480/600, 230/400/460/575,
220/380/440/550, 208/500
240 X 480

120/115/110
24
24
24
110/115/120
120
115
95/115
110 X 220
24 X 115, 23 X 110, 25 X 120
99/120/130, 95/115/125,
91/110/120, 85/100/110
120 X 240

VA
Rating

Voltage Letter
A 

Voltage Letter
B 

Voltage Letter
C 

Voltage Letter
D 

Voltage Letter
E 

Catalog No

Catalog No

Catalog No

Catalog No

Catalog No

50
75
100
150
200
250
300
350
500
750
1000
1500
2000
3000
5000

MT0050A
MT0075A
MT0100A
MT0150A
MT0200A
MT0250A
MT0300A
MT0350A
MT0500A
MT0750A
MT1000A
MT1500A
MT2000A
MT3000A
MT5000A

MT0050B
MT0075B
MT0100B
MT0150B
MT0200B
MT0250B
MT0300B
MT0350B
MT0500B
MT0750B
—
—
—
—
—

Voltage Letter
G 

Voltage Letter
H 

Voltage Letter
I 

Catalog No

Catalog No

VA
Rating

Catalog No

50
75
100
150
200
250
300
350
500
750
1000
1500
2000
3000
5000

MT0050G
MT0075G
MT0100G
MT0150G
MT0200G
MT0250G
MT0300G
MT0350G
MT0500G
MT0750G
MT1000G
MT1500G
MT2000G
MT3000G
MT5000G

 Includes
 A 2-pole

List Price $

List Price $

List Price $

—
—
—
—
—

List Price $

MT0050H
MT0075H
MT0100H
MT0150H
MT0200H
MT0250H
MT0300H
MT0350H
MT0500H
MT0750H
MT1000H
MT1500H
MT2000H
MT3000H
MT5000H

secondary fuse clip on sizes 50–750VA.
primary Class CC fuse kit is available for field
installation. See page 8/77 for details. Catalog Number:
KCCFPX2R.

8/78

—

List Price $

MT0050C
MT0075C
MT0100C
MT0150C
MT0200C
MT0250C
MT0300C
MT0350C
MT0500C
—
—
—
—
—
—

MT0050I
MT0075I
MT0100I
MT0150I
MT0200I
MT0250I
MT0300I
MT0350I
MT0500I
MT0750I
MT1000I
MT1500I
MT2000I
MT3000I
—

—
—
—
—
—
—

List Price $

—

List Price $

MT0050D
MT0075D
MT0100D
MT0150D
MT0200D
MT0250D
MT0300D
MT0350D
MT0500D
—
—
—
—
—
—

—
—
—
—
—
—

A
B
C
D
E
F
G
H
I
J
L
M

Voltage Letter
F

List Price $

MT0050E
MT0075E
MT0100E
MT0150E
MT0200E
MT0250E
MT0300E
MT0350E
MT0500E
MT0750E
MT1000E
—
—
—
—

Letter

—
—
—
—

Catalog No

List Price $

MT0050F
MT0075F
MT0100F
MT0150F
MT0200F
MT0250F
MT0300F
MT0350F
MT0500F
MT0750F
—
—
—
—
—

—
—
—
—
—

Voltage Letter
J 

Voltage Letter
L 

Voltage Letter
M 

Catalog No

Catalog No

Catalog No

List Price $

MT0050J
MT0075J
MT0100J
MT0150J
MT0200J
MT0250J
MT0300J
MT0350J
MT0500J
—
—
—
—
—
—

—
—
—
—
—
—

MT0050L
—
MT0100L
MT0150L
—
MT0250L
—
MT0350L
MT0500L
MT0750L
—
—
—
—
—

List Price $

—

—
—

—
—
—
—
—

MT0050M
MT0075M
MT0100M
MT0150M
MT0200M
MT0250M
MT0300M
MT0350M
MT0500M
MT0750M
—
—
—
—
—

List Price $

—
—
—
—
—

 Includes secondary fuse clip on sizes 50–500VA.
 Does not include secondary fuse clip on any size.

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Industrial Control Power Transformers

International, Class MTG
Selection

Ordering Information
왘

왘
왘
왘

VA
Rating

50
75
100
150
200
250
300
350
500
750
1000
1500
2000
3000
5000

Use the Voltage Table to determine
the primary and secondary voltage
required.
Field Modifications see page 8/90.
Dimensions see page 8/114.
Wiring Diagrams see page 8/149.

Voltage Letter
A

Voltage Letter
B

Catalog No

Catalog No

List Price $ Catalog No

MTG0050B
MTG0075B
MTG0100B
MTG0150B
MTG0200B
MTG0250B
MTG0300B
MTG0350B
MTG0500B
MTG0750B
MTG1000B
—
—
—
—

MTG0050C
MTG0075C
MTG0100C
MTG0150C
MTG0200C
MTG0250C
MTG0300C
MTG0350C
MTG0500C
MTG0750C
MTG1000C
—
—
—
—

List Price $

MTG0050A
MTG0075A
MTG0100A
MTG0150A
MTG0200A
MTG0250A
MTG0300A
MTG0350A
MTG0500A
MTG0750A
MTG1000A
MTG1500A
MTG2000A
MTG3000A
MTG5000A

Siemens Industry, Inc.
Industrial Controls Catalog

Voltage Table

Voltage Letter
C

—
—
—
—

Primary Volts 50/60 Hz

Secondary Volts

240 X 480, 230 X 460, 220 X 440
240 X 480
120 X 240
550/575/600
380/400/415
208/230/460, 200/220/440, 240/480
380

120/115/110
24
24
110/115/120
110 X 220
24 X 115, 23 X 110, 25 X 120
24

Voltage Letter
E

List Price $

—
—
—
—
—

Catalog No

MTG0050E
MTG0075E
MTG0100E
MTG0150E
MTG0200E
MTG0250E
MTG0300E
MTG0350E
MTG0500E
MTG0750E
—
—
—
—
—

Voltage Letter
I

List Price $ Catalog No

—
—
—
—
—

Product Category: NEMA

MTG0050I
MTG0075I
MTG0100I
MTG0150I
MTG0200I
MTG0250I
MTG0300I
MTG0350I
MTG0500I
MTG0750I
—
—
—
—
—

Letter
A
B
C
E
I
J
P

Voltage Letter
J

Voltage Letter
P

List Price $

Catalog No

Catalog No

—
—
—
—
—

MTG0050J
MTG0075J
MTG0100J
MTG0150J
MTG0200J
MTG0250J
MTG0300J
MTG0350J
MTG0500J
MTG0750J
MTG1000J
—
—
—
—

List Price $

—
—
—
—

MTG0050P
MTG0075P
MTG0100P
MTG0150P
MTG0200P
MTG0250P
MTG0300P
MTG0350P
MTG0500P
MTG0750P
—
—
—
—
—

List Price $

—
—
—
—
—

8/79

Field Modification Kits

Class SMF, MMS, MRS
Selection
Accessories—Class SMF

Accessories—Class MMS, MRS

Description

Catalog
Number

Handle Guard Kit with Padlock Provision
Emergency Off Actuator
Additional Key for Key Operated Devices

SMFFL1
SMFPB1
SMFFK1

List
Price $

Pilot Light Kits—Class MMS, MRS

Device

Class SMF

Voltage
Rating

115–277V AC

SMFFL1
SMFPB1
SMFFK1

Voltage
Rating

Catalog Number List Price $ Catalog Number List Price $

Device

SMFPL10

110–120V AC
Class MMS 208–277V AC
440–600V AC

SMFPL10G

List
Price $

Red
Pilot Light

Green
Pilot Light

Catalog Number List Price $ Catalog Number List Price $

SMFPL11
SMFPL12
SMFPL13

SMFPL11G
SMFPL12G
SMFPL13G

Enclosures—Class MMS

For Use With SMF

Standard Size
NEMA 1
General Purpose

FO1, FO1P, FO2, FO2P, FO3,
FO3P, FO4, FO4P

Oversized
NEMA Type 1
General Purpose

FO1, FO1P, FO2, FO2P, FO3,
FO3P, FO4, FO4P

NEMA 3R, 4, 12
Watertight
Dust-tight

FO1, FO1P, FO2, FO2P, FO3,
FO3P, FO4, FO4P

Catalog
Number

List
Price $

SMFFE2

SMFFE1

SMF40BC1

Nameplates—Class SMF

Enclosure Type

For Use With MMS

Standard Size
NEMA 1
General Purpose
Oversized
NEMA Type 1
General Purpose
Jumbo
NEMA Type 1
General Purpose
NEMA 3R, 4, 12
Watertight
Dust-tight

KO1, KO1P, KO1B, KO2,
KO2A, KO2B, KO3, KO3A,
KO3B, KO4, KO4A, KO4B
KO1, KO2B, KO2C, KO3,
KO3A, KO3B, KO4, KO4B,
KO4C, KO2
KO1, KO2B, KO2C, KO3,
KO3A, KO3B, KO4, KO4B,
KO4C, KO2
KO1, KO2B, KO2C, KO3,
KO3A, KO3B, KO4, KO4B,
KO4C

Catalog
Number

List
Price $

MMSKE3

SMFKE1

SMFKE2

SMF40BC1

Nameplates—Class MMS
Without
Pilot Light

Nameplate Catalog
Marking
Number

With
Pilot Light
List
Price $

Catalog
Number

None

SMFFN2

—

None

SMFFSN3

SMFFSN4

NEMA 1
None
surface mounted enclosure High
or gray flush plate
Low

SMFFN30
SMFFN31
SMFFN32

SMFFN40
SMFFN41
SMFFN42

Stainless Steel Plate

Handle Guard Kit with Padlock Provision
Emergency Off Actuator
Additional Key for Key Operated Devices

Green
Pilot Light

Enclosure Type

Standard
commercial switch box
cover including
stainless steel plates

Catalog Number

Pilot Light Kits—Class MMS, MRS

Red
Pilot Light

Enclosures—Class SMF

For Use On

Description

Without
Pilot Light
List
Price $

—

For Use On

Standard
commercial switch box
cover including
stainless steel plates
NEMA 1
surface mounted
enclosure or
gray flush plate

Nameplate Catalog
Marking
Number

With
Pilot Light
List
Price $

Catalog
Number

List
Price $

—

None

SMFFN1

—

None
High
Low
Forward
Reverse

SMFFN10
SMFFN11
SMFFN12
SMFFN13
SMFFN14

SMFFN20
SMFFN21
SMFFN22
—
SMFFN24

—

Replacement Parts—Class SMF, MMS
Description

Catalog Number

Replacement Toggle Kits:Type FW and KW (NEMA 4 Metallic Enclosure)

SMFHW1

List
Price $

 Pilot

lights can be field installed on standard NEMA 1
general purpose surface mount enclosures, and
NEMA 3R, 4 and 12 enclosures only.
For flush mounting units a complete switch unit with
pilot light must be ordered.

8/80

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Field Modification Kits

Class 11 - 3RV
Selection

Description

Type

Catalog Number

1 SPDT contact, NO/NC
1 NO ѿ 1 NC
1 SPDT contact NO/NC electronic contact 
1 NO ѿ 1 NC
2 NO
2 NC
2 NO ѿ 2 NC

3RV1901-1D
3RV1901-1E
3RV1901-1G
3RV1901-1A
3RV1901-1B
3RV1901-1C
3RV1901-1J

1NO + 1NC for any trip
+
1NO + 1NC for short
circuit trip only.

3RV1921-1M

List Price $

Auxiliary Contact Blocks

3RV1901-1D

3RV1901-1A

3RV1912-1CP0

Plug in contact block
1 block per 3RV
mountable at the front
Side mount auxiliary
contact with
screw connection
1 side mount auxiliary
contact per 3RV mountable
on the left-hand side
Signaling Contact Block
Signaling contact
1 signaling contact per 3RV
mountable on the left-hand
side. Can also be fitted
together with side mount
auxiliary contact.
Auxiliary Releases
Undervoltage release
1 undervoltage release
per 3RV mountable on the
right-hand side.
Cannot be fitted together
with shunt trip.
Undervoltage release
with early make contacts (2NO)
1 undervoltage release
per 3RV mountable at
the right-hand side.
Cannot be fitted together
with shunt trip.
Shunt trip
1 shunt trip per 3RV
mountable at the righthand side. Cannot be
fitted together with
undervoltage release.
Pilot Lights
For NEMA 1 enclosure only. Kit
includes Red, Green, and
Amber lenses

3RV1902-1DP0

AC 50Hz
—
230V
415V

AC 60Hz
120V
208V
240V
480V

3RV1902-1AF0
3RV1902-1AM1
3RV1902-1AP0
3RV1902-1AV1

AC 50Hz
230V
415V

AC 60Hz
240V
480V

3RV1922-1CP0
3RV1922-1CV1

AC 50Hz/60Hz
20–24V
90–110V
200–240V
350–415V

DC
20–70V
70–190V
190–330V
330–500V

3RV1902-1DB0
3RV1902-1DF0
3RV1902-1DP0
3RV1902-1DV0

AC 50Hz/60Hz
24V
120V
240V
480V
600V

49SBLBJ
49SBLBF
49SBLBG
49SBLBH
49SBLBE

For 3RV with amp range:
0.11-22A up to 480V Max. 0.11-12.5A up to
575V Max

3RV1928-1H

Four mounting holes required for each 3RV.

3RB1900-0B

For sealing the FLA
adjustment dial
(Kit includes 10 covers)

3RV1908-0P

For sealing the front mount
auxiliary opening. (Kit includes 10 covers)

3RV1901-0H







Lug Kit

Required for Type E Manual
Combination Starter

Mounting
Push-in Mounting Hole Kit
For screw panel mounting
of the 3RV
Sealing device

3RV1928-1H

Adjustment Dial covers
Front mount auxiliary cover
Door Operators

3RV1901-0H

 100% on time.
 5 sec. max. on time.
 Product Category: PILO.

Siemens Industry, Inc.
Industrial Controls Catalog

Thru-the-door operators
Rotary operating mechanism, rated
NEMA 12, lockable with up to
3 padlocks in the OFF position.
Includes extension shift and
connecting element for the 3RV.

130 mm depth

3RV1926-0B

330 mm depth with
supporting bracket

3RV1926-0K

With Black Handle

 Compatible

for use in dusty atmospheres. Contacts
rated for 1-300mA @ 3-60V.

Product Category: IEC

8/81

Field Modification Kits

Pilot Devices
Selection
Push Buttons and
Selector Switches

Class

Enclosure
Type

Controller Size or
(Lighting Rating)

Open

00-4

00-4 or (20–100A)

49SBPB5
14, 40, LEN, CLM

1
5-8 or (200–400A)

49SBSB1
22, 43

30 (2S1W)

00-8 or (20–400A)

Open

00-4
00-4

1

5-8

12, 4/4X

0-8

Open

0-4
0-1 3⁄4

1

2-4

12, 4/4X

0-4

Open
1

0-4
0-4

12, 4/4X

0-4

17, 18, 36, 37, 83, 84,
LED,LEF, LEB, CMN ,
CMF , CMB

1, 12, 4/4X

0-8 (20-400A)

25, 26

1, 12, 4/4X

0-8

32

1, 12, 4/4X

0-4

49SAP05
30 (2S2W)

49SAS01

12, 4/4X

Type

Catalog
Number

Start, Stop Push Buttons
Hand-Off-Auto Selector Switch
Off-On Selector Switch
Start, Stop Push Buttons
Hand-Off-Auto Selector Switch
Off-On Selector Switch
Start, Stop Push Buttons
Hand-Off-Auto Selector Switch
Keyed Hand-Off-Auto (key removable in all positions)
Off-On Selector Switch
Start, Stop Push Buttons
Hand-Off-Auto Selector Switch
Keyed Hand-Off-Auto (key removable in all positions)
Off-On Selector Switch
Forward-Off-Reverse Selector Switch
Forward-Off-Reverse Selector Switch
Forward, Reverse, Stop Push Buttons
Forward-Off-Reverse Selector Switch
Forward, Reverse, Stop Push Buttons
Forward-Off-Reverse Selector Switch
High-Off-Low Selector Switch
High-Off-Low Selector Switch
High, Low, Stop Push Buttons
High-Off-Low Selector Switch
High, Low, Stop Push Buttons
High-Off-Low Selector Switch
High-Off-Low Selector Switch
High-Off-Low Selector Switch
High, Low, Stop Push Buttons
High-Off-Low Selector Switch
Start, Stop Push Buttons
Hand-Off-Auto Selector Switch
Keyed Hand-Off-Auto (key removable in all positions)
Off-On Selector Switch
Forward, Reverse, Stop Push Buttons
Forward-Off-Reverse Selector Switch
High, Low, Stop Push Buttons
High-Off-Low Selector Switch

49SAPB5
49SASB1
49SASB4
49SBPB5
49SBSB1
49SBSB4
49SAP05
49SAS01
49SAS09
49SAS04
49SAP05
49SAS01
49SAS09
49SAS04
49SASB2
49SBSB2
49SAP02
49SAS02
49SAP02
49SAS02
49SASB3
49SBSB3
49SAP03
49SAS03
49SAP03
49SAS03
49SASB3
49SBSB3
49SAP03
49SAS03
49SAP05
49SAS01
49SAS09
49SAS04
49SAP02
49SAS02
49SAP03
49SAS03

List
Price $

 To

be used for replacement of switch only. Does not
include relay or extra contact block on 30-400A CLM
and CM Lighting Contactors. Class 49SB not available
for these devices.

8/82

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Field Modification Kits

NEMA, Lighting and Heating Contactors, 20 Amp CLM, CMB, CMF, CMN
Selection
Solid State Control Module Kits For Lighting and Heating Contactors 
CLM 20 Amp
Contactor Kit
Description

120V AC, 50/60 Hz
24V AC/DC,
50/60 Hz
240/277V AC,
50/60 Hz
12V AC/DC,
50/60 Hz

Accessory

Catalog
Number

List
Price $

Accessory

CLM4379771
47
(2-Wire Control)
(2W)

Catalog
Number

List
Price $

Accessory

CLM4379781

CLM4379772

48
(3-Wire Control)
(3W)

CLM4379773
CLM4379774

CLM4379782
CLM4379783

Catalog
Number

List
Price $

CLM4379791
49
(Start/Stop Control)
(3WS)

CLM4379784

CLM4379792
CLM4379793
CLM4379794

Protective Shielding for NEMA Products

Class 14
Class 40

Disconnect with protective shield

Class 14, 22, 30, 40, 43
Contactor or
Starter Size
Contactor Shield
Catalog Number
Starter Shield
Catalog Number

00–13⁄4

List Price $

2–21⁄2

List Price $

3–31⁄2

List Price $

4

49PSC1

49PSC2

49PSC3

49PSC4

49PSS1

49PSS2

49PSS3

49PSS4

List Price $

Class 17, 25, 32, 87
Disconnect
Size

Catalog
Number

30A
60 & 100A
200A

49PSD5
49PSD6
49PSD7

List Price $

 These

kits are only for use with 20A mechanically held
lighting contactors.

Siemens Industry, Inc.
Industrial Controls Catalog

Product Category: NEMA

8/83

Field Modification Kits

Pilot Lights
Selection
Description

Enclosure
Type

Class

1



Controller Size or
(Lighting Rating)

00–4 or (20–200A)

Lens Color(s)

Legend(s)

Voltage

Catalog
Number

Red, Green, Amber

ON, RUN, OFF ,
OL TRIPPED ,
FORWARD, REVERSE,
LOW, HIGH

Red
(Transformer Type)

ON

Green
(Transformer Type)

OFF

Red, Green, Amber

ON, RUN, OFF ,
OL TRIPPED ,
FORWARD, REVERSE,
LOW, HIGH

Red
(Transformer Type)

ON

Green
(Transformer Type)

OFF

Red
(Transformer Type)

ON

Green
(Transformer Type)

OFF

24 Vac
120 Vac
208/240/277 Vac
480 Vac
600 Vac
24 Vac (Full Voltage)
120 Vac
240 Vac
480 Vac
600 Vac
24 Vac (Full Voltage)
120 Vac
240 Vac
480 Vac
600 Vac
24 Vac
120 Vac
208/240/277 Vac
480 Vac
600 Vac
24 Vac (Full Voltage)
120 Vac
240 Vac
480 Vac
600 Vac
24 Vac (Full Voltage)
120 Vac
240 Vac
480 Vac
600 Vac
24 Vac (Full Voltage)
120 Vac
240 Vac
480 Vac
600 Vac
24 Vac (Full Voltage)
120 Vac
240 Vac
480 Vac
600 Vac

49SBLBJ
49SBLBF
49SBLBG
49SBLBH
49SBLBE
49SPL0BRJ
49SPL0BRF
49SPL0BRG
49SPL0BRH
49SPL0BRE
49SPL0AGJ
49SPL0AGF
49SPL0AGG
49SPL0AGH
49SPL0AGE
49SBLBJ
49SBLBF
49SBLBG
49SBLBH
49SBLBE
49SPL0BRJ
49SPL0BRF
49SPL0BRG
49SPL0BRH
49SPL0BRE
49SPL0AGJ
49SPL0AGF
49SPL0AGG
49SPL0AGH
49SPL0AGE
49SPL0BRJ
49SPL0BRF
49SPL0BRG
49SPL0BRH
49SPL0BRE
49SPL0AGJ
49SPL0AGF
49SPL0AGG
49SPL0AGH
49SPL0AGE

Red, Green, Amber

—

—

49SBLBL



14, 40, 22 , 43 ,

30 (2S2W) ,
LEN, CLM

1

5–8 or (300–400A)

12, 4/4X

0–8 or (20–400A)

49SBLBF
1

0–4

30 (2S1W) 
1

2–4

12, 4/4X

0–4

49SPL0BRF







17, 18, 25, 26 , 32 ,
36, 37, 81, 83, 84, 87, 88,
LED, LEF, LEB,
CMN, CMF, CMB

49SBLBL

 ”Off”

1, 12, 4/4X

Lens Kit ONLY
(30 (2S1W))
1
(14, 40, 22, 43, 30 (2S2W),
LEN, CLM)

PL requires: (1) N.C. aux contact, 49AB01 on
sizes 00-4.
 Class 22, 25, 26, 30, 32, 43, 83 & 84 requires qty. of (2)
pilot light kits. Does not apply to 49SB kits. Select

8/84

0–6 (20–400A)

0–1 3⁄4
00–4 or (20–200A)

appropriate legend plate as a separate item per type
of starter; either “FORWARD” & “REVERSE” or
“LOW” & “HIGH”.
 2S2W is starter size 0–4.

Product Category: NEMA

List
Price $

 Includes
 The “OL

NC aux contact for NEMA starter Size 0–4.
TRIPPED” pilot light with a bimetal OLR,
requires the OLR to have a N.O. contact as well as a
N.C. contact.

Siemens Industry, Inc.
Industrial Controls Catalog

Field Modification Kits

NEMA, Reduced Voltage and Lighting
Selection
Starter/Contactor Auxiliary Contact Kits
Description

Class

Size

14, 17, 18, 22, 25, 26,
30, 32, 36, 37, 40, 43,
83, 84, 87, 88

00-4

14, 17, 18, 22, 25, 26,
36, 37, 40, 43, 87, 88

5, 6

14, 17, 18, 22, 25, 26
40, 43

7, 8

20-60 Amps
LEN, LED, LEF, LEB
100 Amps
200-400 Amps
20 Amps

30-200 Amps
CLM, CMN, CMF, CMB

300-400 Amps

Type
1 NO
1 NC
1 NC Early Break
1 NC Late Break
1 NC Extra Late Break
1 NO Extra Late Make
1 NO & 1 NC
2 NO
4 NO
3 NO & 1 NC
2 NO & 2 NC
2 NO
1 NO & 1 NC
2 NC

Catalog Number
49AB10
49AB01
49AB01EB
49AB01LB
49AB01XLB
49AB10XLM
49AB11
49AB20
49AB40
49AB31
49AB22
3RH1921-1EA20 
3RH1921-1DA11

3RH1921-1EA02

1 NO & 1 NC (Inside L or R)

49CAL18-11

1 NO & 1 NC (Outside L or R)

49CAL18-11B

1 NO
1 NC
2 NO
1 NO & 1 NC
2 NC
1 NO
1 NC
1 NO/NC SPDT
1 NO/NC SPDT
1 NO/NC SPDT
2 NO/NC SPDT
1 NO & 1 NC
2 NC
2 NO
1 Coil Clearing NO & NC
1 NO & 1 NC
2 NC
2 NO
1 Coil Clearing NO & NC

49ACR0
49ACRC
49ACR7
49ACR6
49ACR8
49D22125001
49D22125002
49CE42SPDT
3RH1921-1DA11
CLM4097291
CLM4097292
CLMFCAK11
CLMFCAK02
CLMFCAK20
CLMFCCK11
CLMHCAK11
CLMHCAK02
CLMHCAK20
CLMHCCK11

Type

Catalog Number

2 NO/2 NC DPDT (NEMA A600)

HA261234

1 NO/1 NC 240V
1 NO/1 NC 480V
(2) 1 NO/1 NC SPDT-480V

A02ED62
A02FD64
A02JLD64

List Price $

Disconnect Auxiliary Switch Kits
Disconnect Amp or
CB Rating

Description

Class

Non-fusible
or Fusible Type

17, 25, 32, 37, 83, 84,
30 - 200A
87, 88, LED, LEF, CMN, CMF

MCP

18, 26, 32, 37, 83, 84,
87, 88, LEB, CMB

3A–125A
250A
400A-600A

List Price $

Control Power Transformer Kits
Description

Recommended Transformer Size
Control Size Transformer VA

45 or 50
75
100
150
300

00–21⁄2
3–31⁄2
4
5-6
7-8

Lighting Control

Transformer
50/60HZ

CLM
20A, 2 - 12P
30A, 3P
30A, 6 - 12P
60A, 3P
60A, 4 - 6P
60A, 8 - 12P
100/200A, 3P
100/200A, 5P
300/400A, 3P
LEN
20A, 3 - 12P
30/60A, 3 - 6P
30/60A, 9 - 12P
100/200A, 3P
300/400A, 3P

 Installation of CPTs may require a
 45VA transformer kits will include

150
100
200
100
150
250
200
250
250

Catalog Number

45 VA
50 VA
100 VA
150 VA
200 VA
300 VA
500 VA

KT*050
KT*050P
KT*100
KT*150
KT*200
KT*300
KT*500

List Price $

Replace * with code from Transformer table. Kits used with NEMA 1
general purpose lift-off cover type require extra wide enclosure.
Class 14 Sizes 0-21⁄2
Class 30 (2S2W) Sizes 0-21⁄2
Class 30 (2S1W) Sizes 0-13⁄4

Transformer Table
Primary Volts Secondary Volts Code

120
208
208
240/480
240/480
277
277
600
600

24
24
120
24
120
24
120
24
120

1
G
H
4
8
5
7
6
9

25
25
50
75
150

larger enclosure.
secondary but not
primary fusing. Sizes 50VA and higher include

Siemens Industry, Inc.
Industrial Controls Catalog

VA
Rating

2-pole primary fusing and 1-pole secondary fusing.
Category: MCCB.

 Product

Product Category: NEMA

 For

24VAC control a minimum of 100VA CPT is
required.
 Assembled at the factory.

8/85

Field Modification Kits

ESP200 Accessories
Selection
Accessories
Description

Catalog Number

List Price $

49ASTC1
3UB89848

ESP200 Tamper Resistance Cover

49ASMP1
49ASMP2

ESP100/200 Mounting Plate

49ASMP3

8/86

Starter Mounting Adaptor Plate

49D70084

Mounting Kit

49ASMS1

Universal Reset Operator
8" for class 36, 37 and 81
in NEMA 1, 12 and 3/3R

49MARB

Single Reset (blue)
for class 14, 17, 18, 22, 25, 26, 30 and 32
in NEMA 1, 12 and 4/4X

49MBRS

Single Reset (red)
for class 14, 22 and 30
in NEMA 4/4X

49MBRSR

ESP200 Reset Extender

49ASRE

Oil Tight Boot
For Single and Multi Unit using 49MARSR Resets
Enclosure type 4, 4X

52AABA

Current Transformer 300:5 use with 48ATJ3S00

97CT005

Current Transformer 400:5 use with 48ATK3S00

97CT006

Current Transformer 600:5 use with 48ATL3S00

97CT008

Current Transformer 750:5 use with 48ATM3S00

97CT009

Current Transformer 1200:5 use with 48ATN3S00

97CT012

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Field Modification Kits

NEMA Accessories
Selection

Miscellaneous Kits
Description

Enclosure
Type

Class

Mechanical Interlock
for Horizontally
Mounted Contactors

Open

Mechanical Interlock

14, 40

Open

Includes wire &
mounting plate

14, 40

Open

14, 40

Open

All but
Class LE, CLM

All

00–4

All but
Class LE, CLM

All

00–13⁄4

LEN, LED, LEF, LEB

All

20 Amps

CLM

All

20 Amps

LEN, CLM

Open

30, 60 Amp

49MCMPMA

All but
Class LE, CLM

All

00–13⁄4

49SAE

14, 40

All

2-21⁄2
3-31⁄2
4 Line 4 Load

49SAAF
49SAAH
75D35994002

14, 40

All

5, 6

3RT1966-4G

14, 40

All

7
8

49ZATK750-3
49ZATK1650-6

All

All

All

49D11960001

All

All

All

49D45584002

Includes
mounting plate
(Different Frame Sizes)
Surge Suppressor for 120V AC
coil. Limits transient voltage
produced by the coil to 220%
maximum peak line volts.
NO 36A at 600V AC Max
NC 25A at 600V AC Max

2 NC (mounts to contactor or power pole)
2 NO (mounts to contactor or power pole)
2 NO (mounts to contactor only)
1 NO (mounts to contactor only)
Top or Bottom, 2-Pole
Main Contacts
Top, 3-Pole
Lighting Contactors
Top or Bottom, 4-Pole
Top or Bottom, 6-Pole

Auxiliary
Power Pole

Lug Kit for Contactors
Item
49SAAF
49SAAH
75D35994001

Mounting Kit for Open
Heating & Lighting
6 - 12-poles
Includes 3 power lugs
for making extra
connections to the load
side of the contactor
For AL/CU Wire

Wire Range
2-14
For AL/CU Wire
2/0-14
250MCM-6 Use CU Only

Ground Lug Kit
Meets CSA Standard
22.2 No 14-1973

1 Conductor 2-14
For AL/CU Wire

Lightning Arrestor

Illustration

49CCF22H
49EEF22H
49GGF22H
49HHP22H
49JJG22H
3RT1954-2A
3RA1963-2A
3RA1973-2A
3RA1962-2A
3RA1972-2A
49VM750H
49VM1650H
49CCF22HP
49EEF22HP
49GGF22HP
49HHP22HP
49JJG22HP

14, 40

Base Plate Only

Load Side
Power Take
Off Kit

Catalog Number List Price $

Open

Interlock Only

Auxiliary
Power Pole

00–1
1 3⁄4
2, 2 1⁄2
3, 3 1⁄2
4
5, 6
5
6
5
6
7
8
00–1
1 3⁄4
2, 2 1⁄2
3, 3 1⁄2
4
Left
2, 2 1⁄2
3, 3 1⁄2

14, 40

Includes wire

Wire Kit Only

Surge
Suppressor

Controller
Size

Right
3, 3 1⁄2
2, 2 1⁄2



49L107944
49L107945
49D26344

49SAF0
49SAFC
49LN02A
49LN20A
49LS20A
49LS10A
CLM4097331
CLM4097332
CLM4097333
CLM4097334

Backspin Timer

On delay timer that reduces
risk of starting into a
backspin

87, 88

All

All

3RP2025-1AQ30
3RP2025-1AP30

Hole Plug

Covers the hole that is
typically used for the
conduit hub

87

All

1-4

49D41149006

Description

Contactor

Wire Size

Catalog Number

Lug Kit
1 Kit = 1 Terminal block. 1 kit
necessary for each line and load.

NEMA size 4 (Vacuum)
NEMA size 5
NEMA size 6

2/0 to 600 MCM, max. one 500MCM
& one 600MCM

3RT1966-4G

List Price $

3RT1966-4G
 Surge

Suppression for NEMA sizes 5 – 8 are supplied
internal with the coil. For size 4 panel mount.

Siemens Industry, Inc.
Industrial Controls Catalog

 Only

3 lugs are suplied for line or load.
If lugs for line and load are required order 2 kits.

Product Category: NEMA

 Lug

Kit for contactors include 3 lugs for line or load.
75D35994001 for line side.
75D35994002 for load side.

8/87

Field Modification Kits

NEMA Accessories
Selection

Fused and Non-Fused Disconnect Switch Kits (Includes load base plus line and load fuse clips)
Basic
Switch
Ampere
Rating

Switch
Catalog
Number
Non-Fused

List
Price $

Switch
Catalog
Number
Fused

30

HNB612

60

HNB623

100

HNB623

HFB21
HFB612
HFB22
HFB62
HFB63

200

HNB64

HFB64

List
Price $

Kit
Description

Load Base
Catalog
Number
Class J

30A, 250V
30A, 600V
60A, 250V
60A, 600V
100A, 250V
100A, 600V
200A, 250V
200A, 600V

—
HBB612
—
HBB62
—
HBB63
—
HBB64

List
Price $

—

Load Base
Catalog
Number
Class H

List
Price $

Lug
Wire
Size

#14-2 AWG (Cu/AI)

—

HBB21
HBB612
HBB22
HBB62
HBB63

—

HBB64

#6-300 AWG (Cu/AI)

—

#14-2 AWG (Cu/AI)
#14-1/0 AWG (Cu/AI)

Class R Fuse Conversion Kits
Catalog Number

Description

HR21
HR612
HR612
HR62
HR63
HR64

30A, 240V
30A, 600V
60A, 240V
60A, 600V
100A, 240/600V
200A, 240/600V

List Price $

Hazardous Location Accessories For Enclosure Types 7 & 9
Description

Conduit Size Inches

Install in bottom as drain.
Install in top as breather.
Suitable for Class I groups C & D and
for Class II groups F & G applications only.
for 1⁄2" NPT.

Breather/Drain

51AADB

⁄2
⁄4
1
11⁄2
2
21⁄2

51AAHA
51AAHB
51AAHC
51AAHD
51AAHE
51AAHF

3

⁄4–1⁄2
1–1⁄2
11⁄2–3⁄4
11⁄2–1

51AARBA
51AARCA
51AARDB
51AARDC

2 1⁄2–3⁄4
2 1⁄2–1
2 1⁄2–11⁄2
2 1⁄2–2

51AARFB
51AARFC
51AARFD
51AARFE

3–1
3–11⁄2
3–2
3–21⁄2

51AARGC
51AARGD
51AARGE
51AARGF

1
3

For tapered NPT conduit openings.

Hole Plugs

Cast aluminum, UL Recognized and
CSA Certified. Used to reduce existing
tapered NPT conduit opening when
required.

Reducer Bushings

Catalog Number List Price $

Conduit Hubs
Conduit
Size

Description

Conduit Hubs For Enclosures
Noncombination - NEMA 12
may be field modified for NEMA 3/3R.
Combination - NEMA 12 may be field
modified for NEMA 3/3R/4 enclosure.
Use UL Listed conduit hub for
the appropriate NEMA type.
NEMA 3R requires the location of the conduit
hub to be at a level above the lowest live part
and holes of 1/8" dia. to be added in the
bottom of the enclosure.
Does not apply to class 87 Pump Panels.

 Product
 Product

8/88

Category: PILO.
Category: HDSS.

Metal Hub

Metal Hub

3
⁄4"
1"
1 1⁄2"
2"
2 1⁄2"

1"
1 1⁄2"
2"
2 1⁄2"

Class

Controller
Size

Enclosure
Type

Catalog
Number

49MACML
49MACMD
49MACMN
49MACMF
49MACMG

All

All

12, 3, 3R, 4

81, 87

All

3R

List
Price $

75D41149001
75D41149003
75D41149004
75D41149005

 For

Class R fuses order Class H kit from this table and
the Class R conversion kit.

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Field Modification Kits

NEMA, Overload Relays
Selection

Sirius 3RB20
Illustration

Description

For Overload Type

Catalog Number

3RB206

3RU1900-1A

List Price $

Reset mechanisms
Reset plunger
Mounts directly to overload relay. Requires
separate reset operator in enclosure door. Kit
includes reset plunger, holder and funnel.

Reset plunger with reset button
Flexible cable reset mechanism
Requires a 6.5 mm hole in the
enclosure with a maximum
enclosure thickness of 8 mm.

Flexible reset

Cable length
15.75 in (400mm)

3RU1900-1B
3RB206

Cable length
23.62 in (600mm)

3RU1900-1C

Covers
Tamper resistant cover for current setting and manual/automatic reset button.

3RB206

3RB2984-0

Competitive Retrofit Overload Plates
Manufacturer

NEMA
Size

Plate
Part Number

A-B
A-B
Sq. D

0, 1
2
0, 1

49D57090
49D57161
49D57091

List Price $

Electronic Coil System with Remaining Lifetime Indication and 24VDC PLC Output
Class

Size

5
All
6

Model Type

21 - 27V
Catalog Number

P
V
P
V

–
–
–
–

Siemens Industry, Inc.
Industrial Controls Catalog

List Price $
–
–
–
–

96 - 127V
Catalog Number
3RT1965-5PF31
3RT1966-5PF31
3RT1975-5PF31
3RT1976-5PF31

Product Category: NEMA

List Price $

200 - 277V
Catalog Number

List Price $

3RT1965-5PP31
3RT1966-5PP31
3RT1975-5PP31
3RT1976-5PP31

8/89

Field Modification Kits

Class MT, MTG
Selection

Fuse Blocks, Touch-Safe Terminal Covers
Catalog Number

Description

International Fusing 
List Price $

Catalog Number

Description

List Price $

1-Pole Fuse Block,
Touch-Safe. Up to 6.3A
for 5 mm ҂ 20 mm or
5 mm ҂ 25 mm (Requires
DIN Rail Mounting)

2-Pole Primary Class CC
Fuse Block for domestic
fusing. Max 600V.(Single- ole cover kits,
if required are listed
below. One cover kit
required per pole.)

8WA1011-1SF12

KCCFP2RG
1-Pole Fuse Block,
Touch-Safe 25A, for
10 ҂ 38 mm Cylindrical
Fuses. (Requires DIN
Rail Mounting.)

1-Pole Secondary
Midget Fuse Block for
13/32 ҂ 11⁄2 domestic
Fusing. Max 250V.
(Single pole cover kits,
if required are listed
below.)

3NW7011

2-Pole Fuse Block,
Touch-Safe 25A, for
10 ҂ 38 mm Cylindrical
Fuses. (Requires DIN
Rail Mounting.)

KCCF1G

3NW7021

Single Pole Fuse Block
cover Kit for domestic
fuse blocks listed above.
(For primary or secondary)
2-Kits required for 2-pole
fuse block.

1-Pole Fuse Block,
Touch-Safe 4-50A, for
14 ҂ 51 mm Cylindrical
Fuses. (Requires DIN
Rail Mounting.)

KCCFBCK

3NW7111
Snap-On Transformer
Terminal Touch-Safe Cover
Kit. (Includes primary and
secondary covers.)
KTTSC6P (cover for 6
terminals) also available.

Fuse Block DIN Rail
Mounting for separate
screw mounting to panel.
(Max 2-pole 2-25A size
per rail.)
(Max 1-pole 4-50A size
per rail.)

KTTSC4P
(cover for 4 terminals)

 Product

8/90

49FCCPT

Fuse Clips 2 per pack

49JUCPT

Terminals Jumper

8WA1815

Category: IEC.

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Heavy Duty Control

Non-Combination Enclosure Kits, Class 49
Selection
49
Class
49 — Field
Kit

E

B

14

E

B

11

07

05

Reset Installation

Starter Size
E — 00, 0, 1, 13⁄4
G — 2, 21⁄2
I — 3, 31⁄2
J—4

Type
E — Enclosure
Only Model
B — Model
C — 2002

Depth
(In Inches)

R — Reset

Width
(In Inches)

NEMA Type
B — NEMA 1
0 — NEMA 12
W — NEMA 4 S.S.

Product Class
14 — Class 14, 40
22 — Class 22, 43
30 — Class 30

R

Height
(In Inches)

Non-Reversing Starters & Contactors Class 14, 40
General Purpose (Clamshell)

NEMA 4/4X Stainless
Watertight, Dust-tight, Corrosion Resistant

NEMA 12/3/3R

Without CPT

With CPT (Extra Wide)

Without CPT

With CPT (Extra Wide)

Without CPT

Model C Enclosure

Model C Enclosure

Model B Enclosure

Model B Enclosure

NEMA 1

Size

Catalog Number

00–13⁄4
2, 21⁄2
3, 31⁄2
3, 31⁄2
4

49EC14EB110705R
49EC14GB140807R
49EC14IB201208R
—
49EC14JB251409R

List
Price $ Catalog Number

—

49EC14IB201208R
49EC14IB201208R
49EC14IB201208R
49EC14JB251409R
49EC14JB251409R

Model B Enclosure
Max
CPT List
VA Price $ Catalog Number

200
200
100
250
300

List
Price $

49EB14EW130806R
49EB14GW160907R
49EB14JW261408R
—
—
49EB14JW261408R

Catalog Number

Industrial Use, Weatherproof

Max
CPT List
VA
Price $

49EB22EW131306R
49EB22GW161406R
49EB14JW261408R
—
49EB22JW302410R

—

Catalog Number

With CPT (Extra Wide)
Model B Enclosure

List
Price $ Catalog Number

49EB14E0130806R
49EB14G0160907R
49EB14J0261408R
—
—
49EB14J0261408R

Max
CPT List
VA
Price $

49EB22E0131306R
49EB22G0161406R
49EB14J0261408R
—
49EB22J0302410R

—

Reversing Starters & Reversing Contactors Class 22, 43
General Purpose (Clamshell)

NEMA 4/4X Stainless
Watertight, Dust-tight, Corrosion Resistant

NEMA 12/3/3R

Without CPT

With CPT (Extra Wide)

Without CPT

With CPT (Extra Wide)

Without CPT

Model C Enclosure

Model C Enclosure

Model B Enclosure

Model B Enclosure

NEMA 1

Size

Catalog Number

00–13⁄4
2, 21⁄2
3, 31⁄2
4

49EC14IB201208R
49EC14IB201208R
49EC14JB251409R
49EC14JB251409R

List
Price $ Catalog Number

49EC14IB201208R
49EC14IB201208R
49EC14JB251409R
49EC14JB251409R

Model B Enclosure
Max
CPT List
VA Price $ Catalog Number

200
200
250
300

List
Price $

49EB22EW131306R
49EB22GW161406R
49EB22IW261808R
49EB22JW302410R

Catalog Number

Industrial Use, Weatherproof

Max
CPT List
VA
Price $

49EB22EW131306R
49EB22GW161406R
49EB22JW302410R
49EB22JW302410R

Catalog Number

49EB22E0131306R
49EB22G0161406R
49EB22I0261808R
49EB22J0302410R

With CPT (Extra Wide)
Model B Enclosure

List
Price $ Catalog Number

Max
CPT List
VA
Price $

49EB22E0131306R
49EB22G0161406R
49EB22J0302410R
49EB22J0302410R

Two-Speed Two-Winding Starters Class 30
NEMA 1
Without CPT

With CPT (Extra Wide)

Model C Enclosure

Model C Enclosure

Size

Catalog Number

0–13⁄4
2, 21⁄2
3, 31⁄2
4

49EC14IB201208R
49EC14IB201208R
49EC14JB251409R
49EC14JB251409R

List
Price $ Catalog Number

49EC14JB251409R
49EC14JB251409R
49EB22JB302410R
49EB22JB302410R

NEMA 4/4X Stainless
Watertight, Dust-tight, Corrosion Resistant

NEMA 12/3/3R

Without CPT

With CPT (Extra Wide)

Without CPT

Model B Enclosure

Model B Enclosure

Model B Enclosure
Max
CPT List
VA Price $ Catalog Number

200
200
300
300

List
Price $

49EB30EW131306R
49EB30GW161406R
49EB30IW261808R
49EB22JW302410R

Catalog Number

Industrial Use, Weatherproof

Max
CPT List
VA
Price $

49EB30GW161808R
49EB30GW161808R
49EB22JW302410R
49EB22JW302410R

Catalog Number

49EB30E0131306R
49EB30G0161406R
49EB30I0261808R
49EB22J0302410R

With CPT (Extra Wide)
Model B Enclosure

List
Price $ Catalog Number

Max
CPT List
VA
Price $

49EB30G0161808R
49EB30G0161808R
49EB22J0302410R
49EB22J0302410R

Two-Speed One-Winding Starters Class 30
General Purpose (Clamshell)

NEMA 4/4X Stainless
Watertight, Dust-tight, Corrosion Resistant

NEMA 12/3/3R

Without CPT

With CPT (Extra Wide)

Without CPT

With CPT (Extra Wide)

Without CPT

Model C Enclosure

Model C Enclosure

Model B Enclosure

Model B Enclosure

NEMA 1

Size

Catalog Number

0–13⁄4
2, 21⁄2
3, 31⁄2
4

49EC14IB201208R
49EB30GB161808R
49EB30IB192208R
49EB22JB302410R

List
Price $ Catalog Number

49EC14JB251409R
49EB22JB302410R
49EB22JB302410R
49EB22JB302410R

Model B Enclosure
Max
CPT List
VA Price $ Catalog Number

200
300
300
300

Note: Dimensions...See appropriate Product Class
Outline Drawing beginning on page 8/116.
 For

conduit hubs and conversion instructions,
see page 8/88.
 Clamshell enclosure suitable for one operating device
and two pilot lights. See Field Mods page 8/82.

Siemens Industry, Inc.
Industrial Controls Catalog

49EB30EW131306R
49EB30GW161808R
49EB22JW302410R
49EB22JW302410R

List
Price $

Catalog Number

Industrial Use, Weatherproof

Max
CPT List
VA
Price $

49EB30GW161808R
49EB22IW261808R
49EB22JW302410R
49EB22JW302410R

 Hinged

cover enclosure suitable for one or more class
52 operating devices and one or more class 52 pilot
lights. See Field Mods page 8/82.
 Install NEMA 1 hole plug cat. no. 3SB1902-0AR
(included) when the cover OL reset is not needed.
 Install NEMA 12 hole plug cat. no. 52ABH6 (not
included) when the cover OL reset is not needed.

Product Category: NEMA

Catalog Number

49EB30E0131306R
49EB30G0161808R
49EB22J0302410R
49EB22J0302410R

With CPT (Extra Wide)
Model B Enclosure

List
Price $ Catalog Number

Max
CPT List
VA
Price $

49EB30G0161808R
49EB22I0261808R
49EB22J0302410R
49EB22J0302410R

 Install

NEMA 4X stainless steel hole plug cat. no.
52ABHS (not included) when the cover OL reset is not
needed.

8/91

Heavy Duty Control

Lighting Enclosure Tables
Selection

Lighting & Heating Contactors Class LE
NEMA 4/4X Stainless

NEMA 1

General Purpose (Clamshell)

2-12
3
6-9
12
3
6-9
12
3

Industrial Use

Without CPT

With CPT (Extra Wide)

Without CPT

With CPT (Extra Wide)

Without CPT

With CPT (Extra Wide)

Model C Enclosure

Model C Enclosure

Model B Enclosure

Model B Enclosure

Model B Enclosure

Model B Enclosure

Size Pole Catalog Number

20A
30A
30A
30A
60A
60A
60A
100A

NEMA 12/3/3R

Watertight, Corrosion Resistant

49EC14EB110705R
49EC14EB110705R
49EC14IB201208R
49EC14IB201208R
49EC14EB110705R
49EC14IB201208R
49EC14IB201208R
49EC14IB201208R

List
Price $ Catalog Number

49EC14IB201208R
49EC14IB201208R
49EC14IB201208R
49EC14JB251409R
49EC14IB201208R
49EC14IB201208R
49EC14JB251409R
49EC14IB201208R

Max
CPT

List
Price $ Catalog Number

200VA
200VA
200VA
250VA
200VA
200VA
250VA
200VA

List
Price $

49EB22GW161406R
49EB22GW161406R
49EB14JW261408R
49EB14JW261408R
49EB22GW161406R
49EB14JW261408R
49EB14JW261408R
49EB14JW261408R

Catalog Number

Max List
CPT Price $

Catalog Number

49EB22GW161406R
49EB22GW161406R
49EB14JW261408R
—
49EB22GW161406R
49EB14JW261408R
—
49EB14JW261408R

—
—
—
—
—
—
—
—

49EB22G0161406R
49EB22G0161406R
49EB14J0261408R
49EB14J0261408R
49EB22G0161406R
49EB14J0261408R
49EB14J0261408R
49EB14J0261408R

—

—

List
Price $

Catalog Number

49EB22G0161406R
49EB22G0161406R
49EB14J0261408R
—
49EB22G0161406R
49EB14J0261408R
—
49EB14J0261408R

Max List
CPT Price $

—
—
—
—
—
—
—
—

—

—

Lighting & Heating Contactors Class CLM
General Purpose (Clamshell)

NEMA 4/4X Stainless
Watertight, Corrosion Resistant

NEMA 12/3/3R

Without CPT

Without CPT

With CPT (Extra Wide)

Without CPT

Model B Enclosure

Model B Enclosure

NEMA 1

Model C/B Enclosure
Size Pole Catalog Number

20A
30A
30A
60A
60A
100A

2-12
2-5
6-12
2-5
6-12
2-5

49EC14GB140807R
49EC14EB110705R
49EB30GB161808R
49EC14GB140807R
49EB30IB192208R
49EC14IB201208R

With CPT (Extra Wide)
Model C/B Enclosure

List
Price $ Catalog Number

49EC14IB201208R
49EC14IB201208R
49EB30GB161808R
49EC14IB201208R
49EB30IB192208R
49EC14IB201208R

Model B Enclosure

Max
CPT

200VA
200VA
200VA
200VA
250VA
200VA

Note: Dimensions...See appropriate Product Class
Outline Drawing on page 8/129.
 For

conduit hubs and conversion instructions,
see page 8/88.
enclosure suitable for one operating device
and two pilot lights. See Field Mods page 8/82.

 Clamshell

8/92

List
Price $ Catalog Number

49EB22GW161406R
49EB22GW161406R
49EB30GW161808R
—
—
—

List
Price $

—
—
—

Industrial Use

Catalog Number

Max List
CPT Price $

Catalog Number

49EB22GW161406R
49EB22GW161406R
49EB30GW161808R
—
—
—

—
—
—
—
—
—

49EB22G0161406R
49EB22G0161406R
49EB30G0161808R
—
—
—

 Hinged

cover enclosure suitable for one or more class
52 operating devices and one or more class 52 pilot
lights. See Field Mods page 8/82.
 Install NEMA 1 hole plug cat. no. 3SB1902-0AR
(included) when the cover OL reset is not needed.
 Install NEMA 12 hole plug cat. no. 52ABH6 (not
included) when the cover OL reset is not needed.

Product Category: NEMA

—
—
—

With CPT (Extra Wide)
Model B Enclosure

List
Price $

—
—
—

Catalog Number

49EB22G0161406R
49EB22G0161406R
49EB30G0161808R
—
—
—

Max List
CPT Price $

—
—
—
—
—
—

—
—
—

 Install

NEMA 4X stainless steel hole plug cat. no.
52ABHS (not included) when the cover OL reset is not
needed.

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Starter Enclosure Kits

Features and Benefits

Features
▪ Manufactured with a cold forming “TOX” process
▪ 100kA short circuit rating when protected with class R fuses
to 600V or MCP to 480V and when installing listed components
from the instruction guide
▪ Enclosure types available, Nema 1, 12, 3/3R and painted NEMA 4.
Nema 12 field convertible to 3/3R/4 with the appropriate conduit
hub and drain hole
▪ Pre-Drilled mounting panels
▪ Heavy duty quarter turns
▪ Industrial type disconnect handle
Disconnect Type Enclosure Kit
▪ Used to assemble both non-fusible and fusible combination starters
▪ Accommodates Class 14 full voltage non-reversing (FVNR) NEMA
starters 00 – 4 including Siemens exclusive half sizes
▪ Handle mechanism, power wire, mounting panel, reset assembly,
and instruction guide included. Hardware for panel mounted
devices and disconnect switch are not included
MCP Type Enclosure Kit
▪ Used to assemble combination starters with circuit breakers
▪ Accommodates Class 14 full voltage non-reversing (FVRN) NEMA
starters 00 – 4 including Siemens exclusive half sizes
▪ Handle mechanism, power wire, mounting panel, reset assembly
and instruction guide included. Circuit breaker not included however,
mounting hardware for the circuit breaker is
How to Select the Required Kits to Assemble a Combination Starter
1. From the catalog, select a class 14 open type starter with the required
starter size and overload relay type.
2. Based on the starter size, select the enclosure kit from table 1a for
fusible or non-fusible combination starters or select from table 1b
for combination starters with an MCP.
3. For a non-fusible combination starter, select the disconnect switch kit from table 2a.
For a fusible combination starter, select the appropriate disconnect switch, fuse clip
kit, and class R rejection kit from table 2b (for H fusing, class R rejection kit not required).
For combination starters with MCP, select the appropriate circuit breaker kit from table 3.

Nomenclature for Combination Enclosure Kits
49

E

C

17

B

B

24

11

08

R

Class
49 — Field Kit

Reset Installation
R — Reset Installed

Type
E — Enclosure Kit
Model
C — Model C
Product Class
17 — Disconnect Type
18 — Circuit Breaker Type

Depth
(In Inches)
Width
(In Inches)
Height
(In Inches)
Enclosure Type
B — NEMA 1
N — NEMA 12/3R, 4 Painted

Disc / CB Amp Rating

B — 30/60 amp disconnect
C — 100 amp disconnect
D— 125 amp breaker frame
E — 150 amp breaker frame
F — 200 amp disconnect
Siemens Industry, Inc.
Industrial Controls Catalog

8/93

Combination Starter Enclosure Kits
Selection
Table 1a - FVNR Combination Starter Kits for use with Disconnect Devices

Starter
Size
0-2
2 1⁄2 - 3
3 1⁄2 - 4

Disc.
Amp
Rating

NEMA 1

Nema 12, 3/3R, 4 Painted 햲

General Purpose

Industrial Use, Weatherproof, Watertight, Dust-tight

Catalog Number

60
100
200

List Price $

Catalog Number

49EC17BB241108R
49EC17CB242008R
49EC17FB362408R

List Price $

49EC17BN241108R
49EC17CN242008R
49EC17FN362408R

Table 1b. – FVNR Combination Starter Kits for use with MCP Devices

Starter
Size

Max
MCP
Amps

0-2
2 1⁄2 - 3
3 1⁄2
4

50
100
125
150

Nema 12, 3/3R, 4 Painted 햲

NEMA 1
General Purpose

Industrial Use, Weatherproof, Watertight, Dust-tight

Catalog Number

List Price $

Catalog Number

49EC18DB241108R
49EC18DB242008R
49EC18DB362408R
49EC18EB362408R

List Price $

49EC18DN241108R
49EC18DN242008R
49EC18DN362408R
49EC18EN362408R

Table 2a – Non-Fusible Disconnect Kits
Disconnect Switch
Switch Rating
30A
60A
100A
200A

Catalog Number

List Price $

HNB612
HNB623
HNB623
HNB64

Table 2b – Fusible Disconnect Kits
Disconnect Switch
Fuse Clip Ratings

Class

Catalog Number

30A-250V
30A-600V
60A-250V
60A-600V
100A-250V
100A-600V
200A-250V
200A-600V

H
H
H
H
H
H
H
H

HFB21
HFB612
HFB22
HFB62
HFB63
HFB63
HFB64
HFB64

Fuse Clip Kit
List Price $

Rejection Clips for Class R Fusing

Catalog Number

List Price $

HBB21
HBB612
HBB22
HBB62
HBB63
HBB63
HBB64
HBB64

Catalog Number

List Price $

HR21
HR612
HR612
HR62
HR63
HR63
HR64
HR64

Table 3 – Circuit Breaker Kits
MCP Type Used with Solid State
Overload Relay
Starter
Size
0

1

1 3⁄4
2
2 1⁄2
3
3 1⁄2
4

햲

MCP Type Used with
Thermal Overload Relay

Overload
Amp
Range

Motor Circuit
Interrupter
Amps

Circuit
Breaker Kit

Motor Circuit
Interrupter
Amps

Circuit
Breaker Kit

0.75-3.4
3-12
5.5-22

3
10
25

ED63A003
ED63A010
ED63A025

3
10
25

ED63A003
ED63A010
ED63A025

0.75-3.4
3-12
5.5-22
10-40
10-40
13-52
25-100
25-100
50-200
50-200

3
10
25
30
40
50
100
100
125
150

ED63A003
ED63A010
ED63A025
ED63A030
ED63A040
ED63A050
ED63A100
ED63A100
ED63A125
FXD63A150L

3
10
25
30
40
50
100
100
125
150

ED63A003
ED63A010
ED63A025
ED63A030
ED63A040
ED63A050
ED63A100
ED63A100
ED63A125
FXD63A150L

For conduit hubs and conversion instructions,
see page 8/88.

8/94

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Factory Modifications
Selection
Ordering Information
䊳

All modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction
may not apply when certain modifications and special features are added.

Pilot Devices
Description

Modification

Class

Enclosure
Type

14, 17, 18, 36, 37, 40, 83, 84, CLM, CM, LE
22, 25, 26, 43
30, 32
14햲 , 17, 18, 22햲 , 25, 26, 30햲 , 32, 36, 37, 40햲 , 43햲
83, 84
14, 17, 18, 36, 37, 40, 83, 84, LE
CM, CLM

All
All햲
All
All햲
All
All
All

A1

Push Buttons

Start, Stop
Forward, Reverse, Stop
High, Low , Stop
E-Stop
Test Push Buttons

For 24 volt HOA control,
20 Amp contactor only

CM, CLM

1

EM

Off-On

14, 17,18, 22, 25, 26, 30, 32, 36, 37, 40, 43,
83, 84, CLM, CM, LE

All

A4

Auto-Off
Forward-Off-Reverse
High-Off-Low
Hand-Off-Auto (Keyed)
Auto-Off-Low-High

14, 17, 18, 40, 83, 84, CM, CLM, LE
22, 25, 26, 43
30, 32
14, 17, 18, 36, 37, 40, 83, 84, LE, CLM, CM
30, 32

All햲
All
All
All 햲
All햲

A6

Hand-Off-Auto

Selector Switches

Suffix

List Price $

A2
ES
K1
A3
A3

A5
A9
A0

Pilot Lights

Class

Enclosure Type

Lens
Color ➔

Red

Legend➔
Suffix ➔

Green

White

Red
Push-To-Test

Green
Push To-Test

OL
Tripped

Control
Power
On

On
For/Rev
Low/High

On
For/Rev
Low/High

Off

FL햴

FW 햲

FS햲

FT 햲

FU햲

Green Red

Green Amber

On
On
For/Rev
For/Rev
Low/High Low/High Run

Run

Off

Off

FA

FD

FJ

FK

FB

Red

FC

Green
Push To-Test

14, 40, 17, 18, 36, 37, 81, 87,
88, LE, CLM, CM
All
22, 25, 26, 30, 32, 43, 83, 84 All

Coil Options
Class 14, 17, 18, 22, 25, 26, 30, 32, 40, 43, 83햵 , 84햵 , 87, 88
Volts 60 HZ

Volts 50 HZ

Coil Letter
Change

24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600

24
110
110/190–220
—
190–220
240
190–220/380–440
380–440
550

J
F
A
D
G
L
C
H
E

DC Coil 햳

24V
48V
125V
250V

S햶
U
V
W

햲

Controller Size — List Price $

AC (50–60 HZ) or DC

Coil Letter
Change

00–21⁄2

3, 31⁄2

4

NC

NC

NC

23–26V
42–48V
110–127V
200–220V
220–240V
240–277V
380–420V
440–480V
575–600V

J
U
F
D
G
L
K
H
E

Not Available on Class 14, 40, 22, 43, 30 (size 00–4) and
Class LE, CLM (20–30amp) NEMA 1 clamshell enclosures.

Siemens Industry, Inc.
Industrial Controls Catalog

Controller Size 4 (Vacuum Only)
Size 5 & 6 (ALL)

NC

Miscellenious Options

Omit Alternator
(deduct)
Duplex with Separate
Relay Alternation
Duplex with lead pump
transfer switch

햳
햴

DC coils include 1 NC, late break aux. contact. This aux.
contact takes up one side of the starter (00–4 only).
Available with solid-state OLR starter sizes 00–8 and
with bimetal OLR starter sizes 00–21⁄2.

Product Category: NEMA

햵
햶

Class

Change the
92 to

List
Price $

83, 84

95

83, 84

93

NC

83, 84

94

NC

For Class 83, 84 standard enclosure (92) alternating
relay available in 24V or 120V control only.
S coil is not available for size 4 contactors or starters.

8/95

Factory Modifications
Selection
Ordering Information
䊳
䊳

Transformer Table
Primary
Volts
120
208
208
240
240
277
277
380
415
480
480/240
480/240
600
600

Replace (*) with letter from Transformer Table.
Prices for modifications are additions to standard equipment prices and are not to be used as separate
selling prices. All modifications will consist of Siemens standard components as available. Standard
equipment dimensions and enclosure construction may not apply when certain modifications and special
features are added.

Secondary
Volts
24
24
120
24
120
24
120
110
100
240
24
120
24
120

Letter
B
S
T
J
F
N
P
U
W
R
D
A
E
C

Control Power Transformers
Description

Standard Capacity 
with 1-Secondary Fuse
Standard Capacity
with 2-Primary and
1-Secondary Fuse
100VA Extra Capacity
with 2-Primary and
1-Secondary Fuse
150VA Extra Capacity
with 2-Primary and
1-Secondary Fuse

Catalog
No Suffix

B*
D*

C*

C*1

Product
Class

Enclosure 20–60
Type
00–2 1⁄2

14, 17, 18, 22, 25, 26, 30,
32, 40, 43, 81, 83 , 84 , 87
14, 17, 18, 22, 25, 26, 30,
32, 40, 43, 81, 83 , 84 , 87,
LE, CLM, CM
14, 17, 18, 22, 25, 26, 30, 32, 40,
43, 81, 83 , 84 , 87, LE, CLM, CM
36, 37, 88
14, 17, 18, 22, 25, 26, 30, 32, 40,
43, 81, 83 , 84 , 87, LE, CLM, CM
36, 37, 88

1, 3, 4, 12
7&9

100

—

200

300–400

—

—

3

31⁄2, 4

5

6

7

8

—
—

—
—

—
—

—
—

—

—

—

—

—
—

—
—

Lighting & Heating Ratings (Amps)
Motor Controller Size

1, 3, 4, 12
7&9
1, 3, 4, 12
7&9
All
1, 3, 4, 12
All

Factory Assembled Fuse Clips—Class 25, 32, 84
Fuse
Clip Amps
30
30
60
60
100
100
200
200
400
400
600
600
800
1600

Volts
250
600
250
600
250
600
250
600
250
600
250
600
600
600

Rejection
Clip Suffix 

Note: Factory will furnish the same voltage coils as
transformer secondary voltage (except with class
36,37).
 The standard control transformer supplied for starter
sizes 00 through 21⁄2 with control voltage other than
24VAC will be rated 45VA and have the appropriate
secondary fuse. Primary fuses will not be supplied as

8/96

List Price $

10
11
12
13
14
15
16
17
18
19
20
21
23
25

standard. For primary fuse option select
appropriate suffix from table.
ESP200 styles add the rejection clip suffix to the
end of the base style catalog number. For thermal
styles add the rejection clip suffix immediately before
the 81 in the part number.

 For

Product Category: NEMA

 For

24VAC control a minimum of 100VA CPT is
required.
84 Duplex Controllers require two fusible
disconnects thus multiply the price adder by two.
 Price x 2 Class 83 and 84.
 Class

Siemens Industry, Inc.
Industrial Controls Catalog

Factory Modifications
Selection
Ordering Information
䊳

Prices for modifications additions to standard equipment prices and are not to be used as separate selling prices. All modifications will
consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction may not apply when
certain modifications and special features are added.

Additional Auxiliary Contacts
Class

햴

14, 17, 18, 40, 83 , 84

햴

22, 25, 26, 43 &
30, 32 (2-winding)

30, 32
(1-winding)

LE, CLM, CM
CLM, CM

Controller Size — List Price $

NO
Contacts

NC
Contacts

Catalog Number
Suffix

5–6

7–8

—
—

1
2

G01
G02

—

—
—

1
1
1

—
1
2

G10
G11
G12

—

—

—

—

2
2
2
2

—
1
2
3

G20
G21
G22
G23

3
3
3

1
2
3

G31
G32
G33

4
4
4
4

—
1
2
4

G40
G41
G42
G44

5
5
5

—
1
3

6
6

00–13⁄4

2–4

—

—
—
—
—

—

—
—

—
—
—

—
—
—
—

—
—
—

—
—

G50
G51
G53

—
—

—
—
—

—
—
—

—
2

G60
G62

—
—

—
—

—
—

7

1

G71

—

—

—

8
—

—
2

G80
G02햲

—

—
—

—
—

2
2
4
4
6
8
0
2
2
4
4
6
8
1
0
2
2

—
2
0
4
2
0
2
—
2
—
4
2
—
1
2
0
2

G20햲
G22햲
G40햲
G44햲
G62햲
G80햲
G02햲
G20햲
G22햲
G40햲
G44햲
G62햲
G80햲
G11
G02햲
G20햲
G22햲

—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—

—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—

—
—
—
—
—
—
—

Overload Options
Class 14, 17, 18, 22, 25, 26, 30, 32, 36, 37
Description

Ambient
Compensated
Bimetal
ESP200
3RB200 (Sz 5-6)

Trip
Class

Phase

Contacts

Catalog Number
Suffix

Class 10 or 20
(K or E heaters)

3-Phase or
Single Phase

NO & NC, SPDT

91

NC

81

Class 5, 10, 20,
30 selectable
Class 10

3-Phase or
Single Phase
3-Phase

NO & NC
NO & NC

Class 20

3-Phase

NO & NC

햲 Auxiliary

contacts will be added evenly across
contactors. (i.e. Class 22, G02 suffix will add 2 NC
contacts (one per contactor).

Siemens Industry, Inc.
Industrial Controls Catalog

Controller Size—List Price $
00–21⁄2

3–4

5, 6

7, 8

—

—

—

—

—

—

—

N/A

—

—

—

—

51
—

—
—

—
—

—
—

—
—

햳

햳 Double the price addition for Class 30 and 32.
햴 For class 83 and 84 contacts will be added to both

starters. Price x 2.

Product Category: NEMA

8/97

Factory Modifications
Selection
Ordering Information
䊳

Prices for modifications additions to standard equipment prices and are not to be used as separate selling prices. All
modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure
construction may not apply when certain modifications and special features are added.

Control Options
Description

Class

Enclosure
Type

Catalog Number
Suffix

Lighting Control Modules
Surge Suppression for 120V AC Coil
Disconnect Switch Interlock 2 NO/2 NC
DPDT
Motor Circuit
NO/NC
SPDT
Protector Interlock
Lightning Arrestor
Circuit Breaker Shunt Trip
Circuit Breaker Undervoltage Trip
Circuit Breaker Alarm Switch Trip
Ground Lug – 1 Conductor
Control Circuit Fuse and Holder
(Transformer Primary Fusing)
Control Circuit Circuit Breaker
Internally Operated
Space Heater (120V separate control)
Space Heater with Thermostat (120V separate control)
Surge Capacitor
Alarm Package (includes horn, light, relay & push-button)
Backspin Protection
Minimum Run Timer 0.2 sec. - 3 mins.
Blown Fuse Indicator Light
Single Phase 120VAC Combination Starter
Single Phase 240VAC Combination Starter

CLM 20 Amp
14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 83, 84, 87, 88
17, 25, 32, 37, 84, CM, LE

All
All
1, 3, 4, 4X, 12

2W, 3W, 3WS
SS
GY

18, 26, 32, 37, 84, CM, LE

All

GY

All
18, 26, 32, 37, 84, 87, 88, CM, LE
18, 26, 32, 37, 84, 87, 88, CM, LE
18, 26, 32, 37, 84, 87, 88, CM, LE
All

All
All
All
All
All

All

All

L
L6
L7
L8
L10
F1 (1 fuse)
F2 (2 fuses)

All

All

F4

All
All
87, 88
83, 84, 87, 88
87, 88
87, 88
17, 25, 32, 37, 84, 87, 88, CM, LE
17, 18
17, 18

All
All
All
All
All
All
All
All
All

SH
ST
SC
M7
T5
T6
L11
Z1
Z1

List
Price $

NC
NC

Reversing Options
Description

Reversing in one speed only 2 speed 1 winding
Reversing in one speed only 2 speed 2 winding
Reversing in both speeds 2 speed 1 winding
Reversing in both speeds 2 speed 2 winding
Reversing for Reduced Voltage

Controller Size —List Price $

Catalog Number
Suffix

Class

0

1

13⁄4

21⁄2

2

31⁄2

3

4

R6
R7
R8
R9
R

30, 32
36, 37

5

—
—
—
—

Enclosure Options Class 36, 37

Class

Enclosure
Type

Change the 8th
Character of the
Catalog Number to:

36
37
37

NEMA 12/3R 
NEMA 4 (Painted)
NEMA 4 (Stainless Steel)

N
E
W

Controller Size — List Price Adder $
0–13⁄4

2, 21⁄2

3

31⁄2, 4

5

6

—

—

Enclosure Options Class 14, 17, 18

Class
14
14 (Extra Wide)
17 & 18

Enclosure
Type
NEMA 4/4X (316 Stainless Steel)
NEMA 4/4X (316 Stainless Steel)
NEMA 4/4X (316 Stainless Steel)

Change the 7th
Character of the
Catalog Number with
Bimetal OLR to:
X
X
X

Change the 8th
Character of the
Catalog Number with
ESP200 OLR to:
X
X
X

Controller Size – List Price Adder $
00–1 3/4

2–2 1/2

3

3 1/2–4

5–8
—
—
—

Note: Add price to the standard 304 stainless steel unit price.

 Supplied

8/98

as NEMA 12, field convertible to NEMA 3R.

 Surge

Suppression for NEMA sizes 5 – 8 are supplied
internal with the coil.

Product Category: NEMA

 Specify

the single phase voltage when ordering.

Siemens Industry, Inc.
Industrial Controls Catalog

Factory Modifications
Selection
Ordering Information
䊳

Prices shown are additions to standard equipment prices as listed in the catalog and are not to be used as separate selling prices.
All modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction
may not apply when certain modifications and special features are added.

Control Relays
Description

4 NO
2 NO/2 NC
4 NC
Under Voltage, Phase Failure, Phase Sequence, Phase Unbalance (460V)
Under Voltage, Phase Failure, Phase Sequence, Phase Unbalance (230V)
Under Voltage, Phase Failure, Phase Sequence, Phase Unbalance (575V)
Ground Fault Relay
Electronic On Delay Relay (.15s–100h) 24V/120V 
Electronic On Delay Relay (.15s–100h) 24V/240V 
Electronic Off Delay Relay (.15s–100s) 120V
Electronic Off Delay Relay (.15s–100s) 240V 
24 hour time clock
24 hour time clock with day omission
7 day time clock
Compelling Relay
Acceleration Control
Deceleration Control
Control Relay 
4-Poles Max

Class

Enclosure
Type

All

1, 3, 4, 7, 9, 12

Suffix

1, 3, 4, 7 & 9, 12
All
1, 3, 4, 7, 9, 12

LE, CLM, CM

All

30, 32

1, 4, 12

List
Price $

R40
R22
R04
R1
R2
R4
R5
T1
T2
T3
T4
T7
T8
T9
A6
A7
A8

Meters—Mounted on Enclosure
Description

Class

Ammeter (includes a C.T. if necessary)
Ammeter and Switch (3-Phase with 3 C.T.’s)
Voltmeter
Voltmeter and Switch (3-Phase)
Elapsed Time Meter
Wattmeter

14, 17, 18, 22,
25, 26, 36, 37, 40,
43, 83, 84

Enclosure
Type

1, 3, 4, 12



Suffix

List
Price $

M1
M2
M3
M4
M5
M6

Function Identification Plates
Description

Class

Suffix

Function identification plate, with marking as specified

All

N1

List Price $

Terminal Blocks
Description
3 Point Terminal
6 Point Terminal
9 Point Terminal

Class

Suffix

List Price $

TC3
TC6
TC9

All

Special Ratings
Description

Class

Suffix

Service Entrance Rating (Included as a standard feature for
product class 81, 84, 87, 88.)

17, 18, 25, 26, 32,
37

N3

 Supplied mounted and unwired.
 Not available on Class 36, 37.
 Price x 2 Class 83 and 84.

Siemens Industry, Inc.
Industrial Controls Catalog

List Price $

 ETM available with 120V coil
 For terminal point more than

only.
9 terminals use
additional suffixes. Max 3 suffixes can be selected.

Product Category: NEMA

 Available

3-Phase only.

8/99

Manual Control

Class SMF, MMS
Dimensions

Class SMF and MMS Open Type

NEMA Type 3R, 4 and 12

(Top and Bottom)
Class SMF
FO–1, 1P, 2, 2P
(with toggle operator)

Types

Class MMS
KO–1, 1A, 1B, 2, 2B, 2C
(with toggle operator)

Types

NEMA Type 1B General Purpose Flush Mounting

Device

Class

Fractional HP Starter

SMF

Motor Starting Switch

MMS

Type

FWN1, 1P, FWN2, 2P
FWN3, 3P, FW4, 4P
KWN1, 1A, 1B, KWN2, 2B, 2C
KWN3, 3A, 3B, KWN4, 4B, 4C

NEMA Type 4 Watertight Die Cast Zinc Enclosure

Device

Type of
Operator

Toggle

Dimensions in Inches (mm)
Type

A

B

C

FF1, 1P, 2, 2P
FS1, 1P, 2, 2P

1.44
(37)
1.44
(37)
1.44
(37)
1.44
(37)
1.75
(44)
1.75
(44)
1.75
(44)
1.75
(44)

2.75
(70)
3.50
(89)
2.75
(70)
3.50
(89)
2.75
(70)
3.50
(89)
2.75
(70)
3.50
(89)

4.50
(114)
5.25
(133)
4.50
(114)
5.25
(133)
4.50
(114)
5.25
(133)
4.50
(114)
5.25
(133)

FSJ1P, 2P

Class SMF
Fractional
HP Starter
Key

FF3, 3P, 4, 4P
FS3, 3P, 4, 4P
FSJ3P, 4P

Class
MMS
Motor
Starting
Switch

Toggle

KF1, 1A, 1B, 2, 2B, 2C
KS1, 1A, 1B, 2, 2B, 2C
KSJ1A, 1B, 2B, 2C

Key

KF3, 3A, 3B, 4, 4B, 4C
KS3, 3A, 3B, 4, 4B, 4C
KSJ3A, 3B, 4B, 4C

Dimensions in Inches (mm)
A

B

C

D

E

F

G

H

I

3.00
(76)

2.75
(70)

1.13
(28)

0.25
(6)

3.75
(95)

4.69
(119)

4.25
(108)

4.56
(116)

0.78
(20)

Device

Class

Type

Fractional HP Starter
Motor Starting Switch

SMF
MMS

FW1, 1P, 2, 2P
KW1, 1A, 1B, 2, 2B, 2C

NEMA Type 1 General Purpose Surface Mounting Enclosures

Standard Size—Class SMF and MMS
Types FG & KG (Single-Unit)
Note: Dimensions for reference, not for construction.
Dimensions are in inches (mm).

8/100

Oversized—Class SMF and MMS
Types FGJ & KGJ (Single-Unit)
 Dimensions

1⁄ 2⬙– 3⁄ 4⬙

Jumbo MMSKE2
Knock-Out On Back and Sides

typical for key operator devices.

Siemens Industry, Inc.
Industrial Controls Catalog

Manual Control

Class SMF, MMS
Dimensions

NEMA Type 7 and 9 Cast Aluminum Enclosure
Dimensions in Inches (mm)
A

B

C

D

G

H

4.00
(101)

5.75
(146)

1.38
(35)

6.36
(161)

4.38
(111)

1.20
(30)

Device

Class

Type

Fractional HP Starter
Motor Starting Switch

SMF
MMS

FR1, FR2
KR1, KR2

NEMA Type 1 General Purpose Enclosure For Two Unit Devices
Type of
Operator

Class

Type

One Starter and
One Sel. Switch

Toggle
Key
Toggle
Key
Toggle
Key

SMF
SMF
SMF
SMF
SMF
SMF

Reversing Switch

Toggle

MRS

Two Speed Starter
Two Speed Switch

Toggle
Toggle

SMF
MMS

FG02, 02P
FG04P
FG222, 222P
FG44P
FG71, 71P, 72, 72P
FG74P
KG11, 11A, 11B, 22, 22A,
22B, 22C
FG11, 11P, 22, 22P
KG11, 11A, 11B, 22, 22B, 22C

Device

One Starter
Two Starters

NEMA Type 1B General Purpose Flush Mounting For Two Unit Devices
Device

Type of
Operator

Class

Type

FF22, 22P
Toggle

SMF
FS22P

Two
Starters

FF44P
Key

SMF
FS44P
FF71, 71P, 72, 72P

One
Starter
and One
Selector
Switch

Toggle

SMF
FS71P, 72P
FF74P

Key

SMF
FS74P

Reversing
Switch
Two
Speed
Switch
Two
Speed
Switch

A

B

C

D

5.25
(133)
4.56
(116)
5.25
(133)
4.56
(116)
5.25
(133)
4.56
(116)
5.25
(133)
4.56
(116)

3.75
(95)
3.50
(89)
3.75
(95)
3.50
(89)
0.75
(19)
3.50
(89)
3.75
(95)
3.50
(89)

5.25
(133)
4.50
(114)
5.25
(133)
4.50
(114)
5.25
(133)
4.50
(114)
5.25
(133)
4.50
(114)

1.44
(37)
1.44
(37)
1.44
(37)
1.44
(37)
2.00
(51)
2.00
(51)
2.00
(51)
2.00
(51)

Toggle

MRS

KF11, 11A, 11B
KF22, 22A
22B, 22C

5.25
(133)

3.75
(95)

5.25
(133)

1.75
(44)

Toggle

SMF

FF11, 11P, 22, 22P

5.25
(133)

3.75
(95)

5.25
(133)

1.44
(37)

Toggle

MMS

KF11, 11A, 11B
22, 22B, 22C

5.25
(133)

3.75
(95)

5.25
(133)

1.44
(37)

Note: Dimensions for reference, not for construction.
Dimensions are in inches (mm).

 Selector

switch is on the left, increases overall depth
to 3.50 in. (89 mm).
one pilot light (located on right) is used on MRS
switches.

 Only

Siemens Industry, Inc.
Industrial Controls Catalog

 Dimensions include factory wired power connections.
 Selector switch is on the left, extends 1.62 in. (41 mm)

from mounting surface.

8/101

Manual Control

Class 11 - 3RV
Dimensions

3RV102

Class 11 - NEMA 7 & 9, 3 & 4, and NEMA 7 & 9
Enclosure

Class 11 - NEMA 1 Enclosure

1/2 NPT

1/2 - 3/4 NPT

3/4 - 1 NPT

3/4 NPT

1/2 - 3/4 NPT
1/2 - 3/4 NPT

1/2 - 3/4 NPT

3/8 Mounting Screw

9.88
10.20

9.19

8.63

8.50

4.63
1/2 - 3/4 NPT

6.06
6.38
7.50

1/2 - 3/4 NPT

6.39

1/4 Mounting Screw
Typ. (3) Places
5.05

3/4 NPT
6.97
5.81

1/2 - 3/4 NPT

3/4 - 1 NPT
.50

Note: Dimensions in inches (millimeters). Dimensions
for reference, not for construction. Contact Sales
Office for dimensions not listed.

8/102

Siemens Industry, Inc.
Industrial Controls Catalog

Heavy Duty Motor Starters

Solid State Overload, Class 14
Dimensions

Figure 2

Figure 1
C
C1

.50

D2

C

B1
B

B1

C1

.50

D2

.50

B

CL

CL

J

A
D

E

J

A

D

L

M
M1

E1
D1

D1
B2

G

E1

Figure 5

Figure 4
B1

B1
.50

D2

K

M
M1

Figure 3
C
C1

L

G

C

B

B

C1

E2
.50

D2

CL

CL

J

J

A
D

A

D

L
K

M
M1

E1

L

G

D1

M
M1

E1
K

G

D1

Open Type Solid State Overload
Outline Dimensions

Mounting
Screw

Mounting Dimensions

Reset Dimensions

Size

Figure

A

B

B1

B2

C

C1

D

D1

D2

E

E1

E2

G

J

K

L

M

M1

00–13⁄4

1

7.44

3.50

5.75

—

3.75

3.50

6.50

2.00

0.19

6.27

1.00

—

#10

5.60

—

0.18

3.23

3.41

(189)

(89)

(146)

(95)

(89)

(165)

(51)

(5)

(159)

(25)

(87)

2–21⁄2

2

8.13

3.50

5.75

4.60

4.00

3.77

7.62

2.00

0.19

—

1.00

—

#10

(207)

(89)

(146)

(117)

(102)

(96)

(194)

(51)

(5)

—

3–31⁄2
4
5
6

3
4
5
6

9.78

4.50

6.75

(248)

(114)

(171)

11.06

4.50

6.75

(281)

(114)

(171)

12.76

5.71

6.89

(324)

(145)

(175)

13.03

6.30

7.48

(331)

(160)

(190)

—
—

5.19

4.66

9.22

1.44

0.28

(132)

(118)

(234)

(37)

(7)

5.75

4.66

10.34

1.44

0.44

(146)

(118)

(263)

(37)

(11)

8.54

—

7.09

4.72

—

(180)

(120)

(217)
—

9.29
(236)

—

7.09

5.12

(180)

(130)

(142)

(25)
—

0.72

—

(18)
—
—

(5)

(82)

6.87

0.48

0.18

3.88

4.06

(174)

(12)

(5)

(99)

(103)

0.25

8.43

0.48

0.18

4.04

4.22

(6)

(214)

(12)

(5)

(103)

(107)

0.72

0.72

0.25

9.35

0.48

0.18

4.04

4.22

(18)

(18)

(6)

(237)

(12)

(5)

(103)

(107)

—

—

0.35

—

—

—

—

—

—

—

—

—

—

(9)
—

—

—

—

0.35
(9)

Note: Dimensions in inches (millimeters). Dimensions
for reference, not for construction. Contact Sales
Office for dimensions not listed.

Siemens Industry, Inc.
Industrial Controls Catalog

8/103

Heavy Duty Motor Starters & Contactors

Ambient Compensated Bimetal Class 14
Dimensions

Figure 2

Figure 1
C1

C

B1

.50

D2

B1

C

B

D2

C1

CL

CL

J

A

A

D

J
D

3 PHASE

L

G

3 PHASE

L

SINGLE PHASE

M1
M

E

SINGLE PHASE

K

M1
M

G

Figure 3

E

D1

Figure 4

B1

B

.50

B
.50

.50

B

C
C1

C
C1

D2

B1
E1

D2

CL
A
J

D
J
D
A

L

L

RESET
R E S E T

G

E

D1

M1
M

B2

M1
M

G

E
D1
B2

Open Type Ambient Compensated Bimetal Overload

Size

Outline Dimensions
Figure A
B
B1

00–13⁄4 1
2–21⁄2

2

3–3 ⁄

3

4

4

12

7.45
(189)
8.38
(213)
10.66
(271)
12.02
(305)

3.50
(89)
3.50
(89)
4.50
(114)
4.50
(114)

5.75
(146)
5.75
(146)
6.75
(171)
6.75
(171)

C

C1

Mounting Dimensions
D
D1
D2

3.89
(99)
4.00
(102)
5.06
(129)
5.75
(146)

3.50
(89)
3.77
(96)
4.66
(118)
4.66
(118)

6.50
(165)
7.75
(197)
9.25
(235)
10.34
(263)

—

2.00
(51)
1.44
(37)
1.44
(37)

0.19
(4.8)
0.19
(4.8)
0.28
(7)
0.44
(11)

Mounting
Screw
G

E

E1

1.00
(25)
1.00
(25)
0.72
(18)
0.72
(18)

—

#10

—

#10

—

0.25
(6)
0.25
(6)

0.72
(18)

Reset Dimensions
J
K

L

M

M1

5.39
(137)
6.28
(160)
7.81
(198)
8.78
(223)

0.16
(4)
0.16
(4)
0.12
(3)
0.12
(3)

2.97
(75)
3.22
(82)
3.39
(86)
3.63
(92)

2.81
(71)
3.06
(78)
3.27
(83)
3.51
(89)

—

0.36
(9)
—
—

Note: Dimensions in inches (millimeters). Dimensions
for reference, not for construction. Contact Sales
Office for dimensions not listed.

8/104

Siemens Industry, Inc.
Industrial Controls Catalog

Reversing & Multispeed Heavy Duty Starters

Solid State Overload Class 22, 30
Dimensions

Figure 1
.50
D1

Figure 2

B1

C

B1

B

C1

B

Figure 3
B1

C
C1

B

D1

C1

.50

D1

.50

C

J
A

D

J

J

A

D

CL

D
A

CL

CL

L

K

K1

M1

G

B2

L

M

E

K

B2

M1
G

K1

K

K1
E

M

M1

G

M

E

Figure 4

Figure 5

B1

B1
B

.50

C

E

D1

C

E

.50

C1

D1

C1

J
A

J

D
D

A

L

L

K

K1

4.05
4.23

G
B

K

K1

M1
M

G

Figure 6

Figure 7
C

B1
E

.50

C

B1
E

C1
D1

C1

.50

D1

L3

J

A
D

A

J
D

L

K

K1

G

M1

B

L

M

K

K1

M1

G

B

M

Class 22 Reversing & Class 30 2 Speed/2 Winding

Size
00–13⁄4
2–21⁄2
3– 3 1⁄2
4

Figure

Outline Dimensions
A
B
B1

B2

C

1
2
3
4

7.69
8.94
11.44
11.91

3.62
3.62
—
—

3.92
4.17
5.65
6.22

7.75
8.25
10.94
10.94

10.50
10.50
12.75
12.75

C1

Mounting Dimensions
D
D1
E

Mounting
Screw
Reset Dimensions
G
J
K
K1

L

M

M1

3.61
3.98
5.03
5.12

7.25
8.50
10.75
11.22

#10
#10
#10
0.25

0.18
0.18
0.18
0.18

3.58
4.23
4.69
4.68

3.40
4.05
4.51
4.50

Mounting
Screw
Reset Dimensions
G
J
K
K1

L

M

M1

#10
#10
#10
#10

0.18
0.18
0.18
0.18

3.58
4.23
4.68
4.68

3.40
4.05
4.50
4.50

0.22
0.22
0.34
0.34

7.25
7.25
10.25
10.25

5.77
7.10
9.18
9.53

1.25
0.77
1.64
0.65

4.75
4.75
6.00
6.00

Class 30 2 Speed/1 Winding

Size
00–1 3⁄4
2–2 1⁄2
3–3 1⁄2
4

Figure

Outline Dimensions
A
B
B1

B2

C

C1

Mounting Dimensions
D
D1
E

1
5
6
7

7.69
9.19
11.44
11.91

3.62
—
—
—

3.92
3.94
5.65
6.22

3.61
3.85
5.07
5.12

7.25
8.75
10.75
10.75

7.75
14.55
16.94
16.94

10.50
16.30
18.75
17.75

0.22
0.22
0.34
0.82

7.25
13.00
16.25
16.25

5.77
7.33
9.18
9.06

1.25
0.77
1.64
1.64

4.75
5.75
6.00
6.00

Note: Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
Dimensions are in inches (mm).

Siemens Industry, Inc.
Industrial Controls Catalog

8/105

Reversing & Multispeed Heavy Duty Starters

Ambient Compensated Bimetal Overload Class 22, 30
Dimensions

Figure 1b

Figure 1a
B1

B1

B
.50

CL

.50

CL

C
C1

D1

B
.50

CL

.50

CL

CL

J

C
C1

D1

CL

J
A

A

D
NC
R
E
S
E
T

NC

R
E
S
E
T

M
A
N
T
R
I
P

X2
T1

T2

NC

T
R
I

P

T1

T2

T
R
I
P

T1

3

THIS OVERLOAD
USED ON
MULTISPEED
STARTERS ONLY

T2

M1

G

NC
R
E
S
E
T

M
A
N

X2

L

T

B2

K1
E

K

R
E
S
E
T

M
A
N

X2

T3

D

T
R
I

P

T1

T3

T2

Figure 2
B1
B
E

L

T

3

THIS OVERLOAD
USED ON
MULTISPEED
STARTERS ONLY

B2

K1
E

K

M

M
A
N

X2

M1

G

M

Figure 3
B1
B
E

C
C1

D1

C

D1

C1

.50

L

L
J

J

D

A

D

A

L
RESET

RESET

RESE T

RESE T

L

M1
M

G

K1

K

G
K

M1
M

K1

Figure 4

Figure 5

B1
B

B

C
C1

D1

B1

C
C1

D1

.50

CL

CL

CL

L

L
J

D

J

A

A
D
NC

L

NC

R
E
S
E
T

R
E
S
E
T

M
A
N
T
R
I
P

X

2

T1

T2

M
A
N

T1

T
3

T2

L

T3

K
K

K1

RESET

RESET

T
R
I
P

X
2

G

E

K1

M1
M

M1
M

G

E

Class 22 Reversing & Class 30 2 Speed/2 Winding with Bimetal Overload

Size

Figure

Outline Dimensions
A
B
B1

00–13⁄4
2–21⁄2
3–31⁄2
4

1a
1b
2
3

7.69
8.94
11.44
12.50

8.25
8.25
10.94
10.94

10.50
10.50
12.94
12.75

B2

C

3.62
3.62
—
—

3.92
4.17
5.66
6.22

C1

Mounting
Screw
D
D1

3.61
3.98
5.08
5.16

7.25
8.50
10.75
11.22

0.22
0.22
0.34
0.34

E

Mounting
Dimensions
G

Reset Dimensions
J
K

K1

L

M

M1

7.25
7.25
10.25
10.25

#10
#10
#10
0.25

5.60
6.46
8.56
9.11

4.75
4.75
6.00
6.00

0.16
0.16
0.12
0.12

3.12
3.10
3.83
4.09

3.07
3.05
3.71
3.97

E

Mounting
Dimensions
G

Reset Dimensions
J
K

K1

L

M

M1

7.25
13.00
16.25

#10
0.25
0.25

5.60
6.71
8.56

4.75
5.75
6.00

0.16
0.16
0.12

3.12
3.10
3.83

3.07
3.05
3.71

1.25
0.79
2.12
2.12

Class 30 2 Speed/1 Winding with Bimetal Overload

Size

Figure

Outline Dimensions
A
B
B1

00–13⁄4
2–21⁄2
3–31⁄2

1a
4
5

7.69
9.19
11.44

8.25
14.56
16.94

10.50
16.25
18.75

B2

C

C1

Mounting
Screw
D
D1

3.62
—
—

3.92
4.11
5.66

3.61
3.92
5.08

7.25
8.75
10.75

0.22
0.22
0.34

1.25
0.78
2.12

Note: Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
Dimensions are in inches (mm).

8/106

Siemens Industry, Inc.
Industrial Controls Catalog

Heavy Duty Contactors

Class 40

Dimensions
Full Voltage Open Type NEMA Contactor Size 00-8
Figure 1

Figure 2

Figure 3

Figure 4

Open Type
Mounting
Dimensions

Mounting
Screw

Size

3rd Character Outline Dimensions
of Catalog No. Fig
A

B

B1

B2

C

D

D1

E

G

00–13⁄4
2–21⁄2
3–31⁄2
4

C, D, E
F,G
H, I
J

1
1
1
1

4.31 (110)
4.88 (124)
6.13 (156)
7.81 (198)

3.94 (100)
3.94 (100)
5.13 (130)
5.19 (132)

4.25 (108)
4.25 (108)
5.50 (140)
5.50 (140)

4.75 (121)
—
—
—

3.75 (70)
4.00 (102)
5.06 (129)
5.75 (146)

3.94 (100)
4.50 (114)
5.63 (143)
6.56 (167)

0.19 (5)
0.19 (5)
0.25 (6)
0.81 (21)

1.00 (25)
1.00 (25)
0.75 (19)
0.75 (19)

#10
#10
0.25 (6)
0.5 (13)

5
6

L
M

2
2

N
P

3
4

5.71 (145)
6.3 (160)
8.27 (210)
17.23 (438)

6.89 (175)
7.48 (190)
—
—

—
—
—
—

8.54 (217)
9.29 (236)
9.53 (242)
10.56 (268)

7.09 (180)
7.09 (180)
9.80 (249)
12.28 (312)

4.72 (120)
5.12 (130)
2.83 (72)
—

—
—
—
5.35 (136)

0.35 (9)
0.35 (9)

7
8

8.27 (210)
8.43 (214)
14.05 (357)
15.41 (392)

Note: Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
Dimensions are in inches (mm).

Siemens Industry, Inc.
Industrial Controls Catalog

0.25 (6)

0.35 (9)

 3rd

character of catalog number identifies contactor
rating.

8/107

Magnetic Reversing Contactors

Class 43

Dimensions
Figure 1

Figure 2

Open Type Horizontal Mounted

Size
00–13⁄4
2, 21⁄2
3–31⁄2
4
5
6

Fig.
1
1
1
1
2
2

Outline Dimensions
A
B
7.69 (195)
7.75 (197)
8.94 (227)
7.75 (197)
11.44 (291)
10.94 (278)
8.50 (216)
10.94 (278)
18.07 (459)
14.20 (361)
11.61 (295)
18.88 (480)

B1
9.25 (235)
9.25 (235)
11.50 (292)
11.50 (292)
—
9.45 (240)

C
3.88 (98)
4.56 (116)
5.19 (132)
6.25 (159)
9.44 (240)
10.85 (276)

C1
—
—
—
—
—
7.44 (189)

Mounting
Dimensions
D
7.25 (184)
8.5 (216)
10.75 (273)
7.81 (198)
17.20 (437)
10.44 (265)

D1
0.25 (6)
0.25 (6)
0.38 (6)
0.38 (6)
—
10.71 (272)

E
3.63 (92)
3.63 (92)
5.13 (130)
5.13 (130)
9.61 (244)
17.72 (450)

F
—
—
—
—

1.18 (30)

Mouning
Screw
G
#10
#10

0.25
0.25
—
—

Note: Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
Dimensions are in inches (mm).

8/108

Siemens Industry, Inc.
Industrial Controls Catalog

Overload Relays & Current Transformers

Solid State Overload
Dimensions

Dimensions “A” Frame—ESP200 Solid State Overload

Overload (55 - 630 Amps), SIRIUS 3RB20

Dimensions “A1” Frame—ESP200 Solid State Overload

Frame Size A

Frame Size A1

Frame Size B

Dimensions

Dimensions “B” Frame—ESP200 Solid State Overload

Current Transformers (all CT’s have the same dimensions)

mm

in.

mm

in.

mm

in.

A

80

3.15

80

3.15

100.4

3.95

B

12.6

0.5

12.6

0.5

8.6

0.34

C

27.7

1.1

28

1.10

32.6

1.28

D

44.85

1.77

44.85

1.77

44.85

1.77

E

34.9

1.37

34.9

1.37

23.5

0.93

F

19.6

0.77

19.6

.077

33.5

1.32

G

48.95

1.93

48.95

1.93

46.23

1.82

H

10.7

0.42

10.7

0.42

10.9

0.43

I

2.3

0.09

2.3

0.09

2.4

0.09

J

80

3.15

80

3.15

104.6

4.12

K

53.9

2.12

53.9

2.12

58.6

2.31

L

66.0

2.6

55.9

2.20

50

1.97

M

89.7

3.53

89.7

3.53

114

4.49

N

10.18

0.40

10.18

0.40

4.7

0.19

O

—

—

10.77

0.42

23.6

0.93

P

—

—

8.62

0.34

21.1

0.83

R

—

—

12.9

0.51

27.1

1.07

S

9.5

0.37

—

—

2.45

0.1

T

5.2

0.21

5.2

0.21

5.2

0.21

Note: When mounted on a plate, torque screws to
11 lb.in. (1.2 Nm).

Siemens Industry, Inc.
Industrial Controls Catalog

8/109

Overload Relays

Panel Mounted Class 48 — Bimetal
Dimensions
Figure 1

Figure 2

Figure 4

Figure 3

Figure 6

Figure 5

Figure 8

Figure 7

Mounting
Dimensions

Reset
Dimensions

C

D

E

J

K

L

3 3⁄16 (81)
3 3⁄16 (81)
3 9⁄16 (90)
3 9⁄16 (90)

3 (76)
3 (76)
3 1⁄2 (89)
3 1⁄2 (89)

1

13⁄4 (44)
27⁄16
27⁄16
3 (76)

3

1

3

1

Outline Dimensions

Mounting
Screw
G

Max
Wire
Size

Approx
Ship Wt
Lbs (Kg)

Ref
Dwg

#10
#10
#10
#10

8
1
00
250 MCM

2 (1)
2 (1)
3 (1)
4 (2)

D51820
D51830
D51833
D52206

Description

Amp
Rating

Fig

A

1-Pole
Bimetal
Ambient
Compensated

25
60
100
180

1
2
3
4

7
3 1⁄2 (89)
⁄8 (22)
4 7⁄8 (124) 7⁄8 (22)
4 7⁄8 (124) 1 1⁄4 (32)
5 15⁄16 (151) 1 1⁄4 (32)

Description

Amp
Rating

Fig

A

B

C

D

E

J

K

K1

K2

L

3-Pole
Bimetal
Ambient
Compensated

30
60
100
180

5
6
7
8

3 5⁄8 (92)
3 7⁄8 (98)
4 7⁄8 (124)
6 1⁄2 (165)

3 1⁄16 (78)
3 1⁄16 (78)
4 7⁄16 (113)
4 7⁄16 (113)

3 1⁄8 (79)
3 1⁄8 (79)
3 9⁄16 (90)
3 9⁄16 (90)

3 (76)
3 (76)
3 1⁄2 (89)
3 1⁄2 (89)

1 1⁄2 (38)
1 1⁄2 (38)
1 5⁄8 (41)
1 5⁄8 (41)

1 1⁄4 (32)
1 1⁄4 (32)
27⁄16 (62)
3 (76)

1 13⁄16 (46)
1 13⁄16 (46)
9
⁄16 (14)
9
⁄16 (14)

—
—
115⁄16 (49)
115⁄16 (49)

—
—
2 (51)
2 (51)

3

B

⁄2 (13)
⁄2 (13)
9
⁄16 (14)
9
⁄16 (14)
1

Mounting
Dimensions

Outline Dimensions

⁄4 (19)
⁄4 (19)
1
⁄2 (13)
1
⁄2 (13)

⁄8 (3)
⁄8 (3)
1
⁄8 (3)
1
⁄8 (3)

Reset
Dimensions
⁄16 (5)
⁄16 (5)
⁄8 (3)
1
⁄8 (3)
3
1

Mtg
Screw
G

Max
Wire
Size

Approx
Ship Wt Ref
Lbs (Kg) Dwg

#10
#10
#10
#10

8
2
00
250 MCM

3 (1)
3 (1)
4 (2)
5 (2)

D54791
D54823
D51868
D52038

Note: Dimensions for reference, not for construction.
Dimensions in inches (mm).

8/110

Siemens Industry, Inc.
Industrial Controls Catalog

Lighting & Heating Contactors

Electrically Held, Class LE
Dimensions

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Figure 6

Open Type Lighting and Heating Contactors
Outline Dimensions

Mounting Dimensions

Contact
Rating
Amps
20–30
20–30
20

Poles
2
3
4

Figure
2
2
1

A
3.36
3.97
3.62

B
2
2.25
2.87

B1
—
—
—

B2
—
—
—

C
2.69
2.88
2.88

C1
—
—
—

D
1.63
3.13
3.13

D1
—
3.25
3.25

E
1.63
1.81
1.78

20
20

8
12

3
3

3.62
3.62

—
—

3.71
—

—
4.55

2.88
2.88

2.97
2.97

3.13
3.13

3.25
3.25

1.78
1.78

60
30–60
30–60
100
200
300
400

3
6
9–12
3
3
3
3

2
4
4
6
5
5
5

4.06
3.87
5.25
5.19
6.77
8.27
8.43

2.88
6.15
18.62
4.00
4.72
5.71
6.3

—
—
—
—
5.91
6.89
7.48

—
—
—
—
—
—
—

3.06
3.06
3.31
4.75
7.09
8.54
9.29

—
—
—
—
—
—
—

3.13
3.18
4.62
4.63
5.12
7.09
7.09

3.25
—
—
4.37
3.94
4.72
5.12

2.25
—
18.00
2.88
—
—
—

Mounting
Screw
#10
#10
#10
#10
#10

#10
#10
0.281
#10
0.28
0.35
0.35

Note: Dimensions for reference, not for construction.
Dimensions in inches (mm).

Siemens Industry, Inc.
Industrial Controls Catalog

8/111

Lighting & Heating Contactors

Mechanically / Magnetically Held Lighting Contactors, Class CLM
Dimensions
CLM Contactor, 20 Amp
Figure 1

Figure 2

Figure 3

G

A
B

D

C

F

E

Open Type Lighting and Heating Contactors
Class

CLM

Figure
Number

Amp
Rating

Number of
Poles

A

B

C

D

E

F

G

1
1
2
2
2
2
2
2
3

30
30
60
60
100
100
200
200
30, 60

2–4
5
2, 3
4, 5
2, 3
4, 5
2, 3
4, 5
6-12

3.31 (84)
4.19 (106)
3.31 (84)
5.06 (129)
4.62 (117)
7.25 (184)
4.62 (117)
7.25 (184)
18.62

1.65 (42)
2.09 (53)
1.65 (42)
2.53 (64)
2.31 (59)
3.62 (92)
2.31 (59)
3.62 (92)
0.312

3.95 (100)
3.95 (100)
3.95 (100)
3.95 (100)
6.00 (152)
6.00 (152)
6.00 (152)
6.00 (152)
4.62

4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
6.62 (168)
6.62 (168)
6.62 (168)
6.62 (168)
5.25

0.23 (6)
0.23 (6)
0.23 (6)
0.23 (6)
0.38 (10)
0.38 (10)
0.38 (10)
0.38 (10)
0.312

4.61 (117)
4.61 (117)
4.94 (125)
4.94 (125)
6.75 (171)
6.75 (171)
6.75 (171)
6.75 (171)
4.98

1.50 (38)
1.50 (38)
1.50 (38)
1.50 (38)
1.88 (48)
1.88 (48)
1.88 (48)
1.88 (48)
18.00

Note: Dimensions for reference, not for construction.
Dimensions in inches (mm).

8/112

Siemens Industry, Inc.
Industrial Controls Catalog

Lighting Control

Machanically Latched 300 and 400 Amps, Class CLM
Dimensions
CLM Contactors 300 Amp

CLM Contactors 400 Amp

Note: Dimensions for reference, not for construction.
Dimensions in inches (mm).

Siemens Industry, Inc.
Industrial Controls Catalog

8/113

Industrial Control Power Transformers

Class MT

Dimensions
Top View

Side View

Dimension “C” does not include the
added height required for secondary
fuse clips—0.50 in. (13 mm) maximum
for type “K” clips.
The Primary Fuse Kit, when installed, will
add a maximum of 0.69 in. (18 mm) to
the transformer “A” dimension and 1.94
in. (49 mm) to the “C” dimension.
A

2-pole Primary Class CC Fuse Block Kit is available
for field installation. See page 8/77 for details.
Catalog Number KCCFPX2R

Note: Dimensions for reference, not for construction.
Dimensions in inches (mm).

Class MT
Approximate Dimensions Inches (mm)
VA
Rating

50 

75 

100 

150 

200 

250 

300 

350 

500 

750

1000
1500
2000
3000
5000

8/114

Approx

Voltage

Letters
A, B, C, D, E, F, I, M
G
H
J
L
A, B, C, D, E, F, I, M
G
H
J
A, B, C, D, E, F, I, M
G
H
J
L
A, B, C, D, E, F, I, M
G
H
J
L
A, B, C, D, E, F, I, M
G
H
J
A, B, C, D, E, F, I, M
G
H
J
L
A, B, C, D, E, F, I, M
G
H
J
A, B, C, D, E, F, I, M
G
H
J
L
A, B, C, D, E, F, I, M
G
H
J
L
A, B, E, F, I
G
H
L
A, E, I
G
H
A, I
G
H
A, I
G
H
A, I
G
H
A
G
H

A
3.00 (76)
3.13 (79)
3.00 (76)
3.25 (83)
4.00 (102)
3.50 (89)
3.38 (86)
3.13 (79)
3.50 (89)
3.38 (86)
3.69 (94)
3.88 (98)
3.63 (92)
4.63 (117)
4.00 (102)
4.19 (106)
4.25 (108)
4.38 (111)
4.44 (113)
4.00 (102)
4.25 (108)
4.25 (108)
4.50 (114)
4.38 (111)
4.75 (121)
4.75 (121)
5.25 (133)
5.86 (149)
4.75 (121)
5.25 (133)
5.13 (130)
5.13 (130)
5.25 (133)
8.25 (149)
5.00 (127)
5.38 (137)
5.63 (143)
5.50 (140)
6.00 (152)
5.88 (149)
6.86 (175)
7.00 (178)
7.00 (178)
7.38 (187)
7.00 (178)
5.63 (143)
7.86 (200)
7.13 (181)
7.50 (191)
6.75 (171)
7.50 (191)
8.25 (210)
7.00 (178)
8.25 (210)
7.56 (192)
7.50 (191)
8.00 (203)
8.63 (219)
10.0 (254)
10.50 (267)
13.50 (343)

B
3.00 (76)
3.00 (76)
3.00 (76)
3.00 (76)
3.38 (86)
3.00 (76)
3.38 (86)
3.38 (86)
3.38 (86)
3.38 (86)
3.38 (86)
3.38 (86)
3.75 (95)
3.38 (86)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
5.25 (133)
4.50 (114)
4.50 (114)
4.50 (114)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
6.75 (171)
5.25 (133)
6.38 (162)
6.38 (162)
6.75 (171)
6.75 (171)
6.75 (171)
6.75 (171)
6.75 (171)
9.00 (229)
9.00 (229)
9.00 (229)
9.00 (229)
9.00 (229)
9.00 (229)
9.00 (229)

C
2.56 (65)
2.56 (65)
3.00 (76)
2.56 (65)
2.88 (73)
2.56 (65)
2.88 (73)
2.88 (73)
2.88 (73)
2.88 (73)
2.88 (73)
2.88 (73)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
4.75 (121)
3.81 (97)
3.81 (97)
3.81 (97)
4.75 (121)
4.44 (113)
4.75 (121)
4.75 (121)
4.75 (121)
4.75 (121)
4.44 (113)
4.75 (121)
4.75 (121)
4.75 (121)
5.75 (146)
4.44 (113)
5.38 (137)
5.38 (137)
5.69 (144)
5.69 (144)
5.69 (144)
5.69 (144)
5.69 (144)
7.31 (186)
7.56 (192)
7.56 (192)
7.56 (192)
7.56 (192)
10.19 (259)
10.56 (268)

D
2.00 (51)
2.13 (54)
2.56 (65)
2.25 (57)
2.44 (62)
2.50 (64)
2.38 (60)
2.38 (60)
2.50 (64)
2.38 (60)
2.69 (68)
2.88 (73)
2.50 (64)
3.06 (78)
2.88 (73)
3.06 (78)
3.25 (83)
3.25 (83)
2.88 (73)
2.50 (64)
2.75 (70)
2.75 (70)
3.00 (76)
2.88 (73)
3.25 (83)
3.19 (81)
3.75 (95)
4.38 (111)
3.25 (83)
3.75 (95)
3.63 (92)
3.88 (98)
3.75 (95)
4.38 (111)
3.75 (95)
4.13 (105)
4.75 (121)
4.25 (108)
4.75 (121)
4.63 (117)
5.25 (133)
6.13 (156)
5.75 (146)
5.75 (146)
5.75 (146)
4.13 (105)
5.50 (140)
4.50 (114)
4.50 (114)
3.56 (90)
4.44 (113)
5.25 (133)
4.44 (113)
5.25 (133)
4.56 (116)
4.04 (103)
4.63 (117)
5.25 (133)
7.50 (190)
6.50 (165)
8.25 (210)

E
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
2.81 (71)
2.50 (64)
2.81 (71)
2.81 (71)
2.81 (71)
2.81 (71)
2.81 (71)
2.81 (71)
3.13 (79)
3.13 (79)
3.13 (79)
3.13 (79)
3.13 (79)
3.13 (79)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
4.38 (111)
3.75 (95)
3.75 (95)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
6.06 (154)
4.38 (111)
5.19 (132)
5.19 (132)
6.06 (154)
6.06 (154)
6.06 (154)
6.06 (154)
6.06 (154)
6.50 (165)
6.50 (165)
6.50 (165)
6.50 (165)
7.20 (183)
6.50 (165)
6.50 (165)

Mounting
Slots
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
5/16 (8) X 11/16 (17)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 9/16 (14)
9/32 (7) X 13/32 (10)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
9/32 (7) X 9/16 (14)
9/32 (7) X 9/16 (14)
9/32 (7) X 9/16 (14)
9/32 (7) X 9/16 (14)
9/32 (7) X 9/16 (14)
9/32 (7) X 9/16 (14)
7/16 (11) X 3/4 (19)
7/16 (11) X 3/4 (19)
7/16 (11) X 3/4 (19)
7/16 (11) X 3/4 (19)
7/16 (11) X 3/4 (19)
7/16 (11) X 3/4 (19)

Ship Wt
Lbs (Kg)
2.6 (1)
2.8 (1)
3.5 (2)
3.4 (2)
4.0 (2)
3.5 (2)
4.3 (2)
4.5 (2)
4.8 (2)
4.2 (2)
4.9 (2)
6.0 (3)
5.9 (3)
6.6 (3)
6.7 (3)
7.4 (3)
7.7 (4)
7.9 (4)
8.8 (4)
8.5 (4)
9.4 (4)
9.0 (4)
10.6 (5)
10.0 (5)
11.1 (5)
9.7 (4)
13.9 (6)
14.7 (7)
11.3 (5)
13.6 (6)
11.7 (5)
15.5 (7)
13.6 (6)
15.6 (7)
16.5 (8)
16.8 (8)
18.6 (8)
19.2 (9)
21.0 (9)
21.5 (10)
21.5 (10)
23.4 (11)
28.1 (13)
30.0 (14)
28.0 (13)
30.5 (14)
28.1 (13)
30.0 (14)
29.2 (13)
30.0 (14)
33.5 (15)
33.5 (15)
38.0 (17)
42.5 (19)
42.5 (19)
53.0 (24)
63.7 (29)
63.7 (29)
140.0 (64)
102.0 (46)
102.0 (46)

Siemens Industry, Inc.
Industrial Controls Catalog

Industrial Control Power Transformers

Class MTG
Dimensions

Top View

Side View

Dimension “C” does not include the
added height required for secondary
fuse clips—0.50 in. (13 mm) maximum
for type “K” clips.
The Primary Fuse Kit, when installed, will
add a maximum of 0.69 in. (18 mm) to
the transformer “A” dimension and 1.94
in. (49 mm) to the “C” dimension.

Note: Dimensions for reference, not for construction.
Dimensions in inches (mm).

Class MTG
Approximate Dimensions Inches (mm)
VA
Rating

50

75

100

150

200

250

300

350

500

750

1000
1500
2000
3000
5000

Voltage

Letters
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C
J
A
A
A
A

Siemens Industry, Inc.
Industrial Controls Catalog

A
3.38 (86)
3.25 (83)
3.38 (86)
3.25 (83)
3.50 (89)
3.25 (83)
3.50 (89)
3.63 (92)
3.63 (92)
3.63 (92)
3.63 (92)
4.38 (111)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.50 (114)
4.38 (111)
4.50 (114)
5.00 (127)
4.38 (111)
4.75 (121)
4.75 (121)
5.50 (140)
5.13 (130)
5.13 (130)
5.13 (130)
5.38 (137)
5.00 (127)
5.00 (127)
5.00 (127)
5.50 (140)
6.00 (152)
5.50 (140)
6.00 (152)
7.25 (184)
7.38 (187)
7.00 (178)
7.38 (187)
5.56 (141)
5.31 (135)
5.56 (141)
7.00 (178)
6.13 (156)
6.44 (164)
6.25 (159)
8.75 (222)

B
3.00 (76)
3.00 (76)
3.00 (76)
3.38 (86)
3.38 (86)
3.38 (86)
3.38 (86)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
6.38 (162)
6.38 (162)
6.38 (162)
6.38 (162)
6.75 (171)
6.75 (171)
9.00 (229)
9.00 (229)

C
3.00 (76)
3.00 (76)
3.00 (76)
3.25 (83)
3.25 (83)
3.25 (83)
3.25 (83)
3.50 (89)
3.50 (89)
3.50 (89)
3.50 (89)
3.50 (89)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
7.19 (183)
5.31 (135)
7.19 (183)
7.19 (183)
7.50 (191)
7.50 (191)
9.38 (238)
9.38 (238)

D
2.50 (64)
2.25 (57)
2.50 (64)
2.25 (57)
2.50 (64)
2.25 (57)
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
3.19 (81)
2.50 (64)
2.50 (64)
2.50 (64)
2.81 (71)
3.19 (81)
2.81 (71)
3.19 (81)
3.50 (89)
3.19 (81)
3.19 (81)
3.19 (81)
4.06 (103)
3.75 (95)
3.75 (95)
3.75 (95)
4.25 (108)
3.75 (95)
3.75 (95)
3.75 (95)
4.25 (108)
4.75 (121)
4.25 (108)
4.75 (121)
6.00 (153)
5.75 (146)
5.38 (137)
5.75 (146)
4.38 (111)
4.06 (103)
4.31 (110)
5.75 (146)
4.94 (125)
5.25 (133)
4.56 (116)
6.50 (165)

E
2.50 (64)
2.50 (64)
2.50 (64)
2.81 (71)
2.81 (71)
2.81 (71)
2.81 (71)
3.13 (79)
3.13 (79)
3.13 (79)
3.13 (79)
3.13 (79)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
5.31 (135)
5.31 (135)
5.31 (135)
5.31 (135)
6.13 (156)
6.13 (156)
6.50 (165)
6.50 (165)

Mounting
Slots
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
9/32 (7) X 9/16 (14)
9/32 (7) X 9/16 (14)
7/16 (11) X 3/4 (19)
7/16 (11) X 3/4 (19)

Approx
Ship Wt
Lbs (Kg)
3.5 (2)
3.4 (2)
3.5 (2)
4.2 (2)
4.8 (2)
4.2 (2)
4.8 (2)
5.9 (3)
5.9 (3)
5.9 (3)
5.9 (3)
7.9 (4)
8.5 (4)
8.5 (4)
8.5 (4)
8.5 (4)
10.6 (5)
10.0 (5)
10.6 (5)
10.6 (5)
11.3 (5)
11.3 (5)
11.3 (5)
15.2 (7)
13.2 (6)
13.2 (6)
13.2 (6)
16.8 (8)
14.9 (7)
14.9 (7)
14.9 (7)
19.2 (9)
21.0 (9)
19.2 (9)
21.0 (9)
27.0 (12)
30.0 (14)
28.1 (13)
30.0 (14)
30.0 (14)
26.3 (12)
26.3 (12)
40.0 (18)
40.0 (18)
45.1 (21)
65.2 (30)
104.8 (48)

8/115

Heavy Duty Motor Starters & Contactors

Enclosed, Class 14, 40
Dimensions

Figure 2

Figure 1
K3
K2

K1

K3

K2
K2

K3

K1

K2

K2

K1

Figure 5

Figure 4
K3

K2

K1

K3

K2

K3

K3

K2

K2

Figure 3

D

A

K2

K2

D

A
K3

K3

D

A

E
B

G

D

A
E
B

G

G

C

K2

K2

C

K3

E
B
G

K3

K1

K3
E
B

C

View is typical for bottom and top
K3

K1

K2
C

K3

K1

K2

NEMA 1 General Purpose Enclosure (Standard width for use with or without CPT)햲

Size

Max
CPT
Size

00–13⁄4
2–21⁄2
3–31⁄2
4
5
6, 7

w/o CPT
w/o CPT
(100VA)
(300VA)
(300VA)
(300VA)

Figure

1
2
3
4
5
5

Mounting
Screw
Conduit Size

A

B

C

D

E

G

K1

K2

K3

K4

K5

Approx
Ship Wt
Lbs (Kg) Ref Dwg

1031⁄32 (279)
1317⁄32 (344)
191⁄8 (486)
247⁄8 (632)
40 (1016)
48 (1219)

613⁄32 (163)
731⁄32 (202)
113⁄8 (289)
133⁄8 (340)
20 (508)
20 (508)

51⁄32 (128)
63⁄8 (162)
711⁄16 (195)
81⁄8 (206)
11 (279)
121⁄2 (317)

8 7⁄32 (209)
101⁄4 (260)
155⁄8 (397)
213⁄4 (552)
375⁄8 (956)
453⁄16 (1148)

45⁄8 (117)
6 (152)
81⁄4 (210)
9 (229)
151⁄4 (387)
10 (254)

1

1

1

3

⁄4–1
1–11⁄4
11⁄2–2
2–21⁄2
1
⁄2–3⁄4
1
⁄2–3⁄4

—
—
—
—
11⁄4–11⁄2
11⁄4–11⁄2

—
—
—
—
2–3
2–21⁄2

10 (5)
15 (7)
26 (12)
37 (17)
135 (36)
150 (44)

K3

K4

K5

Approx
Ship Wt
Lbs (Kg) Ref Dwg

—
—
—

—
—
—

26 (12)
26 (12)
37 (17)

Outline Dimensions

Mounting Dimensions

⁄4
1
⁄4
1
⁄4
1
⁄4
1
⁄4
1
⁄4

⁄2
1
⁄2–3⁄4
1
⁄2–3⁄4
1
⁄2–3⁄4
2–3
2–21⁄2

⁄2–3⁄4
3
⁄4–1
1–11⁄4
11⁄4–11⁄2
11⁄4–11⁄2
11⁄4–11⁄2

D68870
D68870
D68870
D68870
D65608
D65608013

NEMA 1 General Purpose Enclosure (Extra wide for use with CPT)햲

Size

Max
CPT
Size

00–13⁄4 (200VA)
2–21⁄2 (200VA)
3–31⁄2 (250VA)

Outline Dimensions
Figure A

3
3
4

191⁄8 (486)
191⁄8 (486)
241⁄8 (632)

Mounting
Screw
Conduit Size

B

C

D

E

G

K1

K2

113⁄8 (289)
113⁄8 (289)
133⁄8 (340)

711⁄16 (195)
711⁄16 (195)
81⁄8 (206)

155⁄8 (397)
155⁄8 (397)
213⁄4 (552)

81⁄4 (210)
81⁄4 (210)
9 (229)

1

1

1

1

1–11⁄4
11⁄2–2
1–11⁄4
11⁄2–2
1–11⁄4–11⁄2 2–21⁄2

Note: Dimensions in inches (millimeters). Dimensions
for reference, not for construction. Contact Sales
Office for dimensions not listed.

8/116

Mounting Dimensions

⁄4
⁄4
1
⁄4

⁄2–3⁄4
⁄2–3⁄4
1
⁄2–3⁄4

D68870
D68870
D68870

햲 Clamshell

enclosure Size 00 - 4; Standard width and
Extra wide.

Siemens Industry, Inc.
Industrial Controls Catalog

Heavy Duty Motor Starters & Contactors

Enclosed, Class 14, 40
Dimensions

Figure 1

Figure 2

Figure 3

Figure 4

G

G

D

A
T R

T R

ESE

ESE

B

C MAX

K2

G

E

K1

Typical view
top and bottom
K3

NEMA 4X Fiberglass Enclosures (Standard width for use with or without CPT)
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

Mtg Screw Conduit Size
G
K1
K2

0–21⁄2
3–4

1
1

14.620 (371) 11.880 (302)
23.780 (604) 23.780 (604)

6.890 (175)
6.890 (175)

1⁄4
15.000 (381) 9.750 (248)
24.125 (612.7) 21.250 (539.7) 1⁄4

—
—

—
—

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

—
—

11 (4.9)
28 (12.7)

24-139-861-001
24-139-861-003

NEMA 7/9/3/4 Hazardous Location Enclosure (Standard width for use with or without CPT)
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

0–13⁄4 w/o CPT
2–21⁄2 (0–13⁄4 w/ CPT)
3
31⁄2–4
5

2
2
2
2
2

15.250 (387)
17.750 (451)
17.750 (451)
28.688 (729)
48.875 (1038)

10.000 (254)
10.375 (264)
10.375 (264)
11.750 (298)
14 7/8 (377)

8.500 (216)
10.625 (270)
10.625 (270)
18.375 (467)
29 (373)

10.688 (272)
14.688 (373)
14.688 (373)
17.750 (451)
22.875 (581)

9.125 (132)
13.250 (337)
13.250 (337)
15.750 (400)
213⁄5 (533)

Mtg Screw Conduit Size
G
K1
K2

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

⁄
⁄
3⁄4
3⁄4
3⁄4

33 (14.9)
60 (27.0)
60 (27.0)
140 (63.5)
352 (159)

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

34

⁄

60 (27.0)

Mtg Screw Conduit Size
G
K1
K2

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

⁄
⁄
1⁄4

—
—
—

—
—
—

12 (5)
18 (8)
49 (22)

Mtg Screw Conduit Size
G
K1
K2

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

⁄
⁄
1⁄4
3⁄8
3⁄8
3⁄8

—
—
—
—
—
—

—
—
—
—
—
—

Mtg Screw Conduit Size
G
K1
K2

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

⁄
⁄
1⁄4

—
—
—

—
—
—

17.5 (8)
36 (16)
67 (30)

Mtg Screw Conduit Size
G
K1
K2

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

⁄
⁄
⁄
5
⁄16
3⁄8
3⁄8

—
—
—
—
—
—

⁄
⁄
3⁄8
1⁄2
5⁄8

38
38

⁄
⁄
1⁄2
1⁄2
1⁄2
12
12

11⁄2
2
2
3
3

34
34

24-139-865-002
24-139-865-003
24-139-865-003
24-139-865-004
24-139-865-006

NEMA 7/9/3/4 Hazardous Location Enclosure (Extra wide for use with CPT)
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

Mtg Screw Conduit Size
G
K1
K2

0–21⁄2햲

2

17.750 (451) 14.688 (373)

10.375 (264)

10.625 (270) 13.250 (337)

38

⁄

⁄

12

2

24-139-865-003

NEMA 12/3/3R Industrial Use Enclosure (Standard width for use without CPT)
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

0–13⁄4
2–21⁄2
3–4

3
3
3

13.000 (330) 7.750 (197)
16.000 (406) 8.125 (206)
26.000 (660) 13.125 (333)

5.438 (138)
6.063 (154)
7.563 (192)

12.250 (311) 5.000 (127)
15.250 (387) 5.000 (127)
25.250 (641) 10.000 (254)

14
14

—
—
—

D41547
D41547
D41552

NEMA 12/3/3R Industrial Use Enclosure (Extra wide for use with CPT)
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

0–13⁄4
2–2 1⁄2
3–3 1⁄2
4
5
6, 7

3
3
3
3
4
4

13.000 (330)
16.000 (406)
26.000 (660)
29.063 (738)
40.000 (1016)
48.000 (1219)

5.375 (137)
6.125 (156)
7.563 (192)
9.250 (235)
11.000 (279)
12.500 (317)

12.250 (311)
15.250 (387)
25.250 (641)
27.563 (700)
41.000 (1041)
49.000 (1244)

12.625 (321)
13.250 (337)
13.125 (333)
23.188 (589)
20.000 (508)
20.000 (508)

10.000 (254)
11.000 (279)
10.000 (254)
20.000 (508)
10.000 (254)
10.000 (254)

14
14

—
—
—
—
—
—

30 (14)
33 (15)
49 (22)
64 (29)

D17150
D17150
D41552
D17150
D65608007
D65608009

NEMA 4/4X Stainless Steel Enclosure (Standard width for use without CPT)
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

0–13⁄4
2–21⁄2
3–4

3
3
3

13.000 (330) 7.750 (197)
16.000 (406) 8.125 (206)
26.000 (660) 13.125 (333)

5.438 (138)
6.063 (154)
7.563 (192)

12.250 (311) 5.000 (127)
15.250 (387) 5.000 (127)
25.250 (641) 10.000 (254)

14
14

—
—
—

D41546
D41546
D41551

NEMA 4/4X Stainless Steel Enclosure (Extra wide for use with CPT)
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

0–13⁄4
2–21⁄2
3–31⁄2
4
5 (Painted)
6, 7 (Painted)

3
3
3
3
4
4

13.000 (330)
16.000 (406)
26.000 (660)
29.000 (737)
40.000 (1016)
48.000 (1219)

5.375 (137)
6.000 (152)
7.563 (192)
9.250 (235)
11.000 (279)
12.500 (317)

12.250 (311)
15.250 (387)
25.250 (641)
27.500 (699)
41.000 (1041)
49.000 (1244)

12.625 (321)
13.250 (337)
13.125 (333)
23.188 (589)
20.000 (508)
20.000 (508)

Note: Dimensions in inches (millimeters). Dimensions
for reference, not for construction. Contact Sales
Office for dimensions not listed.

Siemens Industry, Inc.
Industrial Controls Catalog

10.000 (254)
11.000 (279)
10.000 (254)
20.000 (508)
10.000 (254)
10.000 (254)

14
14
14

—
—
—
—
—
—

—
—
—
—
—
—

30 (14)
33 (15)
67 (30)
64 (29)

D41917
D42935
D41551
D43292
D65608007
D65608009

for addition of only CPT on size 21⁄2. If pilot
devices are needed, use size 3-31⁄2 enclosure.

햲 Used

8/117

Combination Heavy Duty Starters

Enclosed, Class 17, 18
Dimensions

Figure 1

Figure 2

H
7.0

Typical view
top and bottom

3.0

3.0

H
Typical view
top and bottom

1/2

1 X 1 1/4
X 3/4
Knockout Knockout
6.00
(156)

B

1/2 X 3/4
1 1/2 X 2 Knockout 1 1/2 X 2
Knockout
Knockout

C

B
E

C

D

GA
GA

Mounting
Holes for
1/4" Screws
Qty. 3

E

Mounting
Holes for
1/4" Screws
Qty. 4

D

E

D

Figure 4

Figure 3
8.5

3.5 3.5

H
Typical view
top and bottom

1/2 X 3/4
1 1/2 X 2 Knockout 1 1/2 X 2
Knockout
Knockout

B
D

E

C

G
A

E

Mounting
Holes for
1/4" Screws
Qty. 4

D

NEMA 1 Standard Width 0–6
Mounting
Dimensions

Size

Figure

A

B

C

D

E

G

H

Approx
Ship Wt
Lbs (Kg)

Ref Dwg

0–2
21⁄2, 3
31⁄2, 4
5
6

1
2
3
4
4

24 (610)
24 (610)
36 (914)
72.156 (1833)
79.125 (2010)

11 (279)
20 (508)
24 (610)
20 (508)
22 (559)

8 (203)
8 (203)
8 (203)
11.031 (280)
13 (330)

6.125 (156)
15.00 (381)
14.00 (356)
71 (1803)
78 (1981)

2.125 (54)
2.125 (54)
5.00 (127)
16 (406)
18 (457)

21.00 (533)
21.00 (533)
33.50 (851)
—
—

3.50 (90)
3.50 (90)
5.00 (127)
—
—

35 (16)
48 (22)
101 (46)
250 (113)
275 (125)

D68774001
D68774002
D68774003
D56032005
D56032006

Ref Dwg
D68774002
D68774003

Outline Dimensions

NEMA 1 Extra Wide 0–3
Mounting
Dimensions

Size

Figure

A

B

C

D

E

G

H

Approx
Ship Wt
Lbs (Kg)

0–2
21⁄2, 3

2
3

24 (610)
36 (914)

20 (508)
24 (610)

8 (203)
8 (203)

15.00 (381)
14.00 (356)

2.125 (54)
5.00 (127)

21.00 (533)
33.50 (851)

3.50 (90)
5.00 (127)

48 (22)
101 (46)

Outline Dimensions

Note: Dimensions in inches (mm).
Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.

8/118

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Heavy Duty Starters

Enclosed, Class 17, 18
Dimensions

Figure 2

Figure 1
5.50
(140)

Figure 3

B

B
C

E

B
D

E

C

D

C

H
G

E

Mounting Holes for
1/4" Screws Qty. 4

Mounting Holes for
1/4" Screws Qty. 3

D

AGH

AGH

A

Mounting Holes for
1/4" Screws Qty. 4

Figure 5

Figure 4
C

D

A

Mounting Holes for
No. 10 Screws Qty. 4

E
B

Mounting Holes for
G
3/8" screw. Qty. 4

NEMA 12/3/3R/4 (Painted), 4/4X (Stainless) Standard Width 0–6
Mounting
Dimensions

Size

Figure

A

B

C

D

E

G

H

Approx
Ship Wt
Lbs (Kg)

0–2
21⁄2, 3
31⁄2, 4
5 (Painted)
6 (Painted)

1
2
3
4
4

24 (610)
24 (610)
36 (914)
72.156 (1833)
79.125 (2010)

11 (279)
20 (508)
24 (610)
20 (508)
22 (559)

8 (203)
8 (203)
8 (203)
11.031 (280)
13 (330)

6.00 (152)
15.00 (381)
12 (305)
71 (1830)
78 (1981)

2.50 (64)
2.50 (64)
6.00 (152)
16 (406)
18 (457)

25.75 (654)
25.75 (654)
37.75 (959)
—
—

26.75 (680)
26.75 (680)
38.75 (984)
—
—

35 (16)
48 (22)
101 (46)
250 (113)
275 (125)

Ref Dwg
D56033
D56033

Outline Dimensions

Ref Dwg
D56033
D56033
D56033
D56032005
D56032006

NEMA 12/3/3R/4 (Painted), 4/4X (Stainless) Extra Wide 0–3
Mounting
Dimensions

Size

Figure

A

B

C

D

E

G

H

Approx
Ship Wt
Lbs (Kg)

0–2

2
3

24 (610)
36 (914)

20 (508)
24 (610)

8 (203)

15.00 (381)
12.00 (305)

2.50 (64)
6.00 (152)

25.75 (654)
37.75 (959)

26.75 (654)
38.75 (984)

49 (22)
102 (46)

Ref Dwg
—
—
—

Outline Dimensions

21⁄2, 3

8 (203)

NEMA 4X Fiberglass Standard Width 0–4
Mounting
Dimensions

Size

Figure

A

B

C

D

E

G

H

Approx
Ship Wt
Lbs (Kg)

0–13⁄4
2–31⁄2
4

5
5
5

23.75 (603)
23.75 (603)
39.37 (1000)

14.62 (371)
23.75 (603)
29.52 (750)

7.12 (181)
8.50 (216)
12.20 (310)

24.09 (612)
24.06 (611)
40.94 (1040)

12.20 (310)
21.30 (541)
27.95 (710)

—
—
—

—
—
—

42 (19)
44 (20)
55 (25)

Outline Dimensions

Note: Dimensions in inches (mm).
Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.

Siemens Industry, Inc.
Industrial Controls Catalog

8/119

Combination Heavy Duty Starters

Enclosed, Class 18
Dimensions

Figure 1

RESET
OFF
TRIP
ON

A

D

T R

T R

ESE

ESE

B

G (Qty. 4)

C MAX
K2

K1

K3

E

Typical view bottom and top

NEMA 7 & 9, 3, 4 Standard Width 0–4
Outline Dimensions

Mounting
Dimensions

Mounting
Screw
Conduit Size

Size

Figure

A

B

C

D

E

G

K1

K2

K3

0–13⁄4
2–31⁄2
4
5

1
1
1
1

17.38 (441)
28.25 (718)
32.25 (819)
40.875 (1038)

14.69 (373)
17.75 (451)
20.00 (508)
22.875 (581)

10.38 (264)
11.19 (284)
11.50 (292)
14.875 (378)

10.63 (270)
18.38 (467)
22.50 (572)
29 (737)

13.25 (337)
15.75 (400)
17.75 (451)
21.75 (552)

3

3

2
21⁄2
21⁄2
3

1

⁄8
3
⁄8
5
⁄8
5
⁄8

⁄4
3
⁄4
3
⁄4
1
⁄2

⁄2
1
⁄2
1
⁄2
3
⁄4

Approx Ship
Wt Lbs (Kg)

Ref Dwg

60 (27)
160 (72)
250 (113)
360 (163)

24-139-865-003
24-139-865-004
24-139-865-005
—

Note: Dimensions in inches (mm). Dimensions for
reference, not for construction. Contact Sales
Office for dimensions not listed.

8/120

Siemens Industry, Inc.
Industrial Controls Catalog

Reversing Heavy Duty Starters & Contactors

Enclosed, Class 22, 43
Dimensions

K2

K2

K3

K1

Figure 4

Figure 3

Figure 2

Figure 1

K3

K1

G

D

A
D

D

A

T R

ESE

T R

A

ESE

B
G

G

E
B

E
B

C MAX

K2
C

C

E

K1
K3

K1

K3

K2

K1

K3

K2

View is typical for bottom and top

NEMA 1 General Purpose Enclosure (Standard width for use with and without CPT)
Mounting
Mounting Dimensions Screw
Conduit Size

B

C

D

E

G

K1

K2

K3

K4

Approx
Ship Wt
Lbs (Kg)

113⁄8 (289)
133⁄8 (340)
20 (508)
20 (508)

711⁄16 (195)
81⁄8 (206)
11 (279)
121⁄2 (317)

155⁄8 (397)
213⁄4 (552)
375⁄8 (956)
453⁄16 (1148)

81⁄4 (210)
9 (229)
151⁄4 (387)
10 (254)

1

1

1–11⁄4
11⁄4–11⁄2
11⁄4–11⁄2
11⁄4–11⁄2

11⁄2–2
2–21⁄2
1
⁄2–3⁄4
1
⁄2–3⁄4

—
—
11⁄4–11⁄2
11⁄4–11⁄2

30 (14)
52 (24)
135 (36)
150 (44)

Outline Dimensions
Size

Figure A

00–21⁄2 (200 VA)
3–4 (300 VA)
5 (300 VA)
6, 7 (300 VA)

1
2

191⁄8 (486)
247⁄8 (632)
40 (1016)
48 (1219)

⁄2–3⁄4
1
⁄2–3⁄4
2–3
2–21⁄2

⁄4
1
⁄4
1
⁄4
1
⁄4

Ref Dwg

D68870
D68870
D65608
D65608013

NEMA 4/4X Stainless Steel Enclosure (with or without CPT)
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

Mtg Screw Conduit Size
G
K1
K2

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

0–13⁄4
2–21⁄2
3–31⁄2 (w/o CPT)
3–31⁄2 (w/ CPT)
4
5 (Painted)
6, 7 (Painted)

3
3
3

13 (330)
16 (406)
251⁄16 (637)

125⁄8 (321)
131⁄4 (337)
173⁄16 (437)

53⁄8 (137)
6 (152)
73⁄8 (187)

121⁄4 (311)
151⁄4 (387)
245⁄16 (618)

10 (254)
11 (279)
14 (356)

14

3

29 (737)

233⁄16 (589)

91⁄4 (235)

271⁄2 (699)

20 (508)

40 (1016)
48(1219)

20 (508)
20 (508)

11 (279)
121⁄2 (317)

41 (1041)
49 (1244)

10 (254)
10 (254)

38

14

⁄
⁄
1⁄4

—
—
—

—
—
—

—
—
—

30 (14)
33 (15)
53 (24)

D41917
D42935
D17423

5 16

⁄

—

—

—

64 (29)

⁄
3⁄8

—
—

—
—

—
—

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

⁄
⁄

140
150

D43292
D65608007
D65608009

NEMA 7/9/3/4 Hazardous Location Enclosure (with or without CPT)
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

Mtg Screw Conduit Size
G
K1
K2

0–21⁄2
3–4

4
4

281⁄4 (718)
321⁄4 (819)

91⁄4 (235)
99⁄16 (243)

183⁄8 (467)
221⁄2 (572)

12

12

12

12

161⁄4 (413)
181⁄4 (464)

153⁄4 (400)
173⁄4 (451)

⁄
⁄

⁄
⁄

3
3

34
34

24-139-865-004
24-139-865-005

Note: Dimensions in inches (mm).
Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.

Siemens Industry, Inc.
Industrial Controls Catalog

8/121

Reversing Heavy Duty Starters & Contactors

Enclosed, Class 22, 43
Dimensions
Figure 5

Figure 6

Figure 7

.188 5.00

12.50

10.00

1.20

48.00
45.75

2.38

.69

15.25
20.00

4-POINT MOUNTING
FOR .31 SCREWS

A

29.88
DOOR
OPEN
90°

.38 HOLE DIA.
FOR PADLOCK

A

B C B

11.62

16.50

7.25

K3

12.75

K2

10.00

0

K1

0.50

2.71

A COMB. K.O.’s FOR 1.00, 1.25, 1.50, 2.00, OR 2.50 CONDUIT
B COMB. K.O.’s FOR 1.00, 1.25, OR 1.50 CONDUIT
C COMB. K.O.’s FOR 0.50 OR 0.75 CONDUIT

View is typical for bottom and top

NEMA 12/3/3R Industrial Use Enclosure (with or without CPT)
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

Mtg Screw Conduit Size
G
K1
K2

0–13⁄4
2–21⁄2
3–31⁄2 (w/o CPT)
3–31⁄2 (w/ CPT)
4
5
6 (300 VA CPT max.)

5
5
5

13 (330)
16 (406)
251⁄16 (637)

125⁄8 (321)
131⁄4 (337)
173⁄16 (437)

53⁄8 (137)
61⁄8 (156)
73⁄8 (187)

121⁄4 (311)
151⁄4 (387)
245⁄16 (618)

10 (254)
11 (279)
14 (356)

14

5

291⁄16 (738)

233⁄16 (589)

91⁄4 (235)

279⁄16 (700)

7
7

40 (1016)
48 (1219)

20 (508)
20 (508)

11 (279)
121⁄2 (318)

41 (1041)
453⁄4 (1162)

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

14

⁄
⁄
⁄

—
—
—

—
—
—

—
—
—

30 (14)
33 (15)
53 (24)

20 (508)

5 16

⁄

—

—

—

64 (29)

10 (254)
10 (254)

38

⁄
1⁄4

—
—

—
—

—
—

14

D17150
D17150
D17150
D17150
D65608007

NEMA 4X Fiberglass Enclosure (with or without CPT)
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

Mtg Screw Conduit Size
G
K1
K2

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

0–21⁄2
3–4

6
6

23.78 (604)
23.78 (604)

6.89 (175)
6.89 (175)

224⁄5 (579)
224⁄5 (579)

14

⁄
⁄

—
—

35
38

14.68 (373)
23.78 (604)

134⁄5 (351)
224⁄5 (579)

14

—
—

—
—

—
—

Note: Dimensions in inches (mm).
Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.

8/122

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Reversing Heavy Duty Starters

Enclosed, Class 25, 26
Dimensions

Figure 1
7.0

3.0

Figure 2

3.0

8.5

H

H

Typical view
top and bottom

1 1/2 X 2
Knockout

1/2 X 3/4
Knockout

1 1/2 X 2
Knockout

1 1/2 X 2
Knockout

C

D

Typical view
top and bottom

1/2 X 3/4
1
Knockout 1 /2 X 2
Knockout

B
E

Figure 3

3.5 3.5

B
D

E

C

G
A

GA

Mounting
Holes for
1/4" Screws
Qty. 4

E

E

D

Mounting
Holes for
1/4" Screws
Qty. 4

D

Figure 4

Figure 5

Figure 6

B
E

C

D

RESET
OFF
TRIP
ON

A

D

T R

T R

ESE

ESE

AGH
B

Mounting Holes
for 3/8" screws Qty. 4

C MAX

Typical view
top and bottom

K2

Mounting Holes for
1/4" Screws Qty. 4

K1

E

K3

NEMA 1 Standard Width 0–6
Mounting
Dimensions

Size

Figure

A

B

C

D

E

G

H

Approx
Ship Wt
Lbs (Kg)

0–21⁄2
3–4
5 (Painted)
6 (Painted)

1
2
3
3

24 (610)
36 (914)
72.156 (1833)
79.125 (2010)

20 (508)
24 (610)
20 (508)
22 (559)

8 (203)
8 (203)
11.031 (280)
13 (330)

15.00 (381)
14.00 (356)
71 (1803)
78 (1981)

2.125 (54)
5.00 (127)
16 (406)
18 (457)

21.00 (533)
33.50 (851)
—
—

3.50 (90)
5.00 (127)
—
—

60 (27)
121 (55)
250 (113)
275 (125)

D68774002
D68774003
D56032005
D56032006

Ref Dwg

D68774005
D68774006
D56032005
D56032006

Outline Dimensions

Ref Dwg

NEMA 12/3/3R/4 (Painted), 4/4X (Stainless) Standard Width 0–6
Mounting
Dimensions

Size

Figure

A

B

C

D

E

G

H

Approx
Ship Wt
Lbs (Kg)

0–21⁄2
3–4
5 (Painted)
6 (Painted)

5
5
3
3

24 (610)
36 (914)
72.156 (1833)
79.125 (2010)

20 (508)
24 (610)
20 (508)
22 (559)

8 (203)
8 (203)
11.031 (280)
13 (330)

15.00 (381)
12 (305)
71 (1803)
78 (1981)

3.50 (90)
6.00 (152)
16 (406)
18 (457)

25.75 (654)
37.75 (959)
—
—

26.75 (654)
38.75 (984)
—
—

63 (29)
124 (56)
250 (113)
275 (125)

Outline Dimensions

NEMA 4X Fiberglass 0–4
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

Mtg Screw Conduit Size
G
K1
K2

0–21⁄2
3–4

4
4

23.780 (604) 14.680 (373)
23.780 (604) 23.780 (604)

6.890 (175)
6.890 (175)

24.125 (612.7) 12.250 (311) 3⁄8
24.125 (612.7) 21.250 (539.7) 3⁄8

—
—

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

—
—

—
—

18 (8)
28 (12.7)

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

⁄

140 (63.5)

24-139-861-001
24-139-861-003

NEMA 7/9/3/4 Hazardous Location 0–4
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

Mtg Screw Conduit Size
G
K1
K2

0–21⁄2
3–4

6

28.688 (729) 17.750 (451)

11.750 (298)

18.375 (467) 15.750. (400)

3⁄8
1⁄2
Contact Sales Office

3

34

24-139-865-004

Note: Dimensions in inches (mm).
Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.

Siemens Industry, Inc.
Industrial Controls Catalog

8/123

Two Speed Heavy Duty Starters

Enclosed, Class 30
Dimensions
Figure 1
K2

K1

Figure 1a
K2

K3

Figure 2
K3

K1

K1

K2

Figure 3

Figure 4

K3

D

A

D

A

D

A

E
B

G

D

A

G

E
B

G

C
E
B

K1

G

K1

C

K3

E
B

C

K3

K2

K2
C

K3

K1

K2

2 Speed 1 Winding
NEMA 1 General Purpose Enclosure (Standard width for use with or without CPT)
Size

Fig

Outline Dimensions
A
B

0–1 3⁄4 w/o CPT
0–1 3⁄4 (200 VA)
2–2 1⁄2
3–3 1⁄2
4

1
1a
2
2
3

19 1⁄8
24 7⁄8
16
18.31
29

(486)
(632)
(406)
(465)
(737)

11 3⁄8
13 3⁄8
17.13
21.19
23 3⁄16

C

(289)
(340)
(435)
(538)
(589)

7 11⁄16
8 1⁄8
7.63
7.38
9 1⁄4

K2

K3

Approx
Ship Wt
Lbs (Kg)

8 1⁄4 (210)
9
(229)
14
(355)
18
(457)
20
(508)

14

⁄
⁄
1⁄4
1⁄4
5⁄16

12 34

14

12 34

⁄–⁄
⁄–⁄
1⁄2–3⁄4
1 1⁄4 –1 1⁄2
—

1–1 1⁄4
1 1⁄4 –1 1⁄2
1 1⁄4 –1 1⁄2
1⁄2 –3⁄4
—

1 1⁄2–2
2–2 1⁄2
1 1⁄4 –1 1⁄2
1 1⁄2–2
—

26
52
39
60
61

(12)
(24)
(20)
(27)
(28)

D68870
D68870
D42932001
D72956002
D43292001

10
14
14
14
20
20

(254)
(355)
(355)
(355)
(508)
(508)

14

⁄
⁄
1⁄4
1⁄4
5⁄16
5⁄16

—
—
—
—
—
—

—
—
—
—
—
—

—
—
—
—
—
—

34
47
47
55
61
61

(15)
(21)
(21)
(25)
(28)
(28)

D41917000

10
14
14
14
20

(254)
(355)
(355)
(355)
(508)

14

Mounting Dimensions
D
E

(195)
(206)
(194)
(187)
(235)

15 5⁄8
21 3⁄4
15.25
17.56
27 1⁄2

(397)
(552)
(387)
(446)
(699)

Mtg
Screw
G

Conduit Size
K1

Ref Dwg

NEMA 4/4X Stainless Steel Enclosure (Standard width for use with or without CPT)

0–1 3⁄4
0–1 3⁄4
2–2 1⁄2
2–2 1⁄2
3–3 1⁄2
4

w/o CPT
w/ CPT
w/o CPT
w/ CPT

3
3
3
3
3
3

13
16
16
25 1⁄16
29
29

(330)
(406)
(406)
(637)
(737)
(737)

12 5⁄8
17 1⁄8
17 1⁄8
17 3⁄16
23 3⁄16
23 3⁄16

(321)
(435)
(435)
(437)
(589)
(589)

5 3⁄8
7 5⁄8
7 5⁄8
7 3⁄8
9 1⁄4
9 1⁄4

(137)
(194)
(194)
(187)
(235)
(235)

12 1⁄4
15 1⁄4
15 1⁄4
24 5⁄16
27 1⁄2
27 1⁄2

(311)
(387)
(387)
(618)
(699)
(699)

14

D43292001
D43292001

NEMA 12/3/3R Industrial Use Enclosure (Standard width for use with or without CPT)

0–1 3⁄4
0–1 3⁄4
2–2 1⁄2
2–2 1⁄2
3–4

w/o CPT
w/ CPT
w/o CPT
w/ CPT

3
3
3
3
3

13
16
16
25 1⁄16
29

(330)
(406)
(406)
(637)
(737)

12 5⁄8
17 1⁄8
17 1⁄8
17 3⁄16
23 3⁄16

(321)
(435)
(435)
(437)
(589)

5 3⁄8
7 5⁄8
7 5⁄8
7 3⁄8
9 1⁄4

(137)
(194)
(194)
(187)
(235)

12 1⁄4
15 1⁄4
15 1⁄4
24 5⁄16
27 1⁄2

(311)
(387)
(387)
(618)
(699)

⁄
⁄
⁄
1⁄4
5⁄16

—
—
—
—
—

—
—
—
—
—

—
—
—
—
—

34
47
47
55
61

(15)
(21)
(21)
(25)
(28)

⁄

—
—

—
—

—
—

28

(13)

14
14

D17150010
D17150010
D19673000

NEMA 4X Fiberglass Enclosure (Standard width for use with or without CPT)

0–2 1⁄2
3–4

4
4

23.780 (604)
39.37 (1000)

23.780 (604)
29.53 (750)

6.890 (175)
12.60 (320)

—
—

—
—

14

—

24139861003
24139861004

2 Speed 2 Winding
NEMA 1 General Purpose Enclosure (Standard width for use with or without CPT)
Size

Fig

Outline Dimensions
A
B

0–2 1⁄2 w/o CPT
0–2 1⁄2 (200 VA)
3–4 w/o CPT

1
1a
1a

19 1⁄8
24 7⁄8
24 7⁄8

(486)
(632)
(632)

11 3⁄8
13 3⁄8
13 3⁄8

(289)
(340)
(340)

C

Mounting Dimensions
D
E

7 11⁄16 (195)
8 1⁄8 (206)
8 1⁄8 (206)

15 5⁄8
21 3⁄4
21 3⁄4

(397)
(552)
(552)

8 1⁄4 (210)
9
(229)
9
(229)

Mtg
Screw
G

K2

K3

Approx
Ship Wt
Lbs (Kg)

14

⁄
⁄
1⁄4

12 34

14

12 34

⁄–⁄
⁄–⁄
1⁄2–3⁄4

1–1 1⁄4
1 1⁄4–1 1⁄2
1 1⁄4 –1 1⁄2

1 1⁄2–2
2–2 1⁄2
2–2 1⁄2

30
52
52

(14)
(24)
(24)

D68870
D68870
D68870

⁄
⁄
1⁄4
1⁄4
1⁄4
5⁄16
5⁄16

—
—
—
—
—
—
—

—
—
—
—
—
—
—

—
—
—
—
—
—
—

34
41
41
41
55
61
61

(15)
(19)
(19)
(19)
(25)
(28)
(28)

D43292001
D43292001

Conduit Size
K1

Ref Dwg

NEMA 4/4X Stainless Steel Enclosure (Standard width for use with or without CPT)

0–1 3⁄4 w/o CPT
0–1 3⁄4 w/ CPT
2–2 1⁄2 w/o CPT
2–2 1⁄2 w/ CPT
3–3 1⁄2 w/o CPT
3–3 1⁄2 w/ CPT
4

3
3
3
3
3
3
3

13
16
16
16
25 1⁄16
29
29

(330)
(406)
(406)
(406)
(637)
(737)
(737)

12 5⁄8
17 1⁄8
13 1⁄4
17 1⁄8
17 3⁄16
23 3⁄16
23 3⁄16

(321)
(435)
(337)
(435)
(187)
(589)
(589)

5 3⁄8
7 5⁄8
6
7 5⁄8
7 3⁄8
9 1⁄4
9 1⁄4

(137)
(194)
(152)
(194)
(187)
(235)
(235)

12 1⁄4
15 1⁄4
15 1⁄4
15 1⁄4
24 5⁄16
27 1⁄2
27 1⁄2

(311)
(387)
(387)
(387)
(618)
(699)
(699)

10
14
11
14
14
20
20

(254)
(355)
(279)
(355)
(355)
(508)
(508)

14

10
14
11
14
14
20

(254)
(355)
(279)
(355)
(355)
(508)

14

14

NEMA 12/3/3R Industrial Use Enclosure (Standard width for use with or without CPT)

0–1 3⁄4 w/o CPT
0–1 3⁄4 w/CPT
2–2 1⁄2 w/o CPT
2–2 1⁄2 w/CPT
3–3 1⁄2 w/o CPT
3–4 w/CPT

3
3
3
3
3
3

13
16
16
16
25 1⁄16
29 1⁄16

(330)
(406)
(406)
(406)
(637)
(738)

12 5⁄8
17 1⁄8
13 1⁄4
17 1⁄8
17 3⁄16
23 3⁄16

(321)
(435)
(337)
(435)
(187)
(589)

5 3⁄8
7 5⁄8
6 1⁄8
7 5⁄8
7 3⁄8
9 1⁄4

(137)
(194)
(156)
(194)
(187)
(235)

12 1⁄4
15 1⁄4
15 1⁄4
15 1⁄4
24 5⁄16
27 9⁄16

(311)
(387)
(387)
(387)
(618)
(700)

⁄
⁄
1⁄4
1⁄4
1⁄4
5⁄16

—
—
—
—
—
—

—
—
—
—
—
—

—
—
—
—
—
—

34
41
41
41
55
61

(15)
(19)
(19)
(19)
(25)
(28)

⁄

—
—

—
—

—
—

28

(13)

14

D17150010
D17150010
D19673000

NEMA 4X Fiberglass Enclosure (Standard width for use with or without CPT)

0–2 1⁄2
3–4

4
4

23.780 (604)
39.37 (1000)

23.780 (604)
29.53 (750)

6.890 (175)
12.60 (320)

—
—

—
—

14

—

24139861003
24139861004

Note: Dimensions in inches (mm). Dimensions for reference, not for construction. Contact sales office for dimensions not listed.

8/124

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Two Speed Heavy Duty Starters

Enclosed, Class 32
Dimensions

Figure 2

Figure 1
7.0

3.0

3.0

8.5

3.5 3.5

H

H

Typical view
top and bottom

1/2 X 3/4
Knockout

1 1/2 X 2
Knockout

Typical view
top and bottom

1/2 X 3/4
1 1/2 X 2 Knockout 1 1/2 X 2
Knockout
Knockout

1 1/2 X 2
Knockout

B
E

C

D

B
D

E

C

G
GA

A

Mounting
Holes for
1/4" Screws
Qty. 4

E

E

D

Mounting
Holes for
1/4" Screws
Qty. 4

D

Figure 4
B

Figure 3

E

C

D

AGH

Mounting Holes for
1/4" Screws Qty. 4

NEMA 1 Standard Width 0–4
Mounting
Dimensions

A

B

C

D

E

G

H

Approx
Ship Wt
Lbs (Kg)

24 (610)
36 (914)
24 (610)
36 (914)

20 (508)
24 (610)
20 (508)
24 (610)

8 (203)
8 (203)
8 (203)
8 (203)

15.00 (381)
14.00 (356)
15.00 (381)
14.00 (356)

2.125 (54)
5.00 (127)
2.125 (54)
5.00 (127)

21.00 (533)
33.50 (851)
21.00 (533)
33.50 (851)

3.50 (90)
3.50 (90)
3.50 (90)
3.50 (90)

68 (31)
71 (32)
135 (61)
138 (63)

D68774
D68774
D68774
D68774

2.50 (64)
6.00 (152)
2.50 (64)
6.00 (152)

25.75 (654)
37.75 (959)
25.75 (654)
37.75 (959)

26.75 (680)
38.75 (984)
26.75 (680)
38.75 (984)

68 (31)
71 (32)
135 (61)
138 (63)

D68774
D68774
D68774
D68774

Outline Dimensions
Size

0–13⁄4
2–4
0–21⁄2,
3–4

Figure

(1 Winding)
(1 Winding)
(2 Winding)
(2 Winding)

1
2
1
2

Ref Dwg

NEMA 12/3/3R/4 (Painted), 4/4X Stainless Standard Width 0–4
0–13⁄4
2–4
0–21⁄2,
3–4

(1 Winding)
(1 Winding)
(2 Winding)
(2 Winding)

4
4
4
4

24 (610)
36 (914)
24 (610)
36 (914)

20 (508)
24 (610)
20 (508)
24 (610)

8 (203)
8 (203)
8 (203)
8 (203)

15.00 (381)
12 (305)
15.00 (381)
12 (305)

Nema 4X Fiberglass 0–4
Size

Figure

Outline Dimensions
A
B

C

Mounting Dimensions
D
E

0–13⁄4
2–4

3
3

23.780 (604) 14.680 (373)
23.780 (604) 23.780 (604)

6.890 (175)
6.890 (175)

24.125 (613) 12.250 (311)
24.125 (613) 21.250 (540)

Mtg Screw Conduit Size
G
K1
K2
1

⁄4
⁄4

1

—
—

—
—

K3

Approx Ship Wt
Lbs (Kg)
Ref Dwg

—
—

18 (8)
28 (13)

—
—

Note: Dimensions in inches (mm).
Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.

Siemens Industry, Inc.
Industrial Controls Catalog

8/125

Reduced Voltage Starters

Class 36, 37
Dimensions

Figure 1

Figure 2
C
H

B

K
L

Handle
(Optional)

C

A

D

A

Mounting Hole
for 1/4" screw

E
B

J
(4) .687 Dia Holes

Restricted Area
for
Auto Transformer

D

G

E

Class 36, 37, NEMA 1, 4, 4X, 12/3R, Combination and Non-combination
Reduced Voltage
AutoTransformer
Size
1 3/4 –2 1/2
3–3 1/2
4
5, 6

8/126

Part Winding & Wye Delta
Circuit
Disconnect Breaker
0–2
0–2 1/2
2 1/2 –3 1/2
3–3 1/2
4
4
5, 6
5, 6

Figure
1
1
1
2

A
43 5/16
55 5/16
74 21/32
90

B
24 5/32
28 9/32
28 9/32
29 30/31

C
11
11
11
20

D
42 11/32
54 11/32
73 13/32
16

E
20
24
24
24 7/16

G
—
—
—

2 16/21

H
—
—
—
1 23/40

I
—
—
—
—

J
—
—
—
1 1/8

K
—
—
—
8 3/40

L
—
—
—
3

Siemens Industry, Inc.
Industrial Controls Catalog

Duplex Heavy Duty Controllers

Class 83, 84
Dimensions

Figure 1

Figure 2

Figure 3

A

Class 83 Non-Combination Type
Enclosure
Type

NEMA 1

NEMA 12

NEMA 4/4X

Size
0–13⁄4
2, 21⁄2
3–4
0–13⁄4
2, 21⁄2
3–4
0–13⁄4
2, 21⁄2
3–4

Outline Dimensions
Figure A
B
1
19 1⁄2
16 1⁄8
1
25 1⁄16
17 3⁄16
1
29 11⁄16
23 3⁄16
2
19 1⁄2
16 1⁄8
2
25 1⁄16
17 3⁄16
2
231⁄2
23 3⁄16
2
19 1⁄2
16 1⁄8
2
25 1⁄16
17 3⁄16
2
29 1⁄16
23 3⁄16

C
6 1⁄2
7 3⁄8
9 1⁄4
6 1⁄2
7 3⁄8
11 1⁄4
6 1⁄2
7 3⁄8
9 1⁄4

Mounting
Dimensions
D
18 3⁄4
24 5⁄16
27 9⁄16
18 3⁄4
24 5⁄16
27 9⁄16
18 3⁄4
24 5⁄16
27 9⁄16

C
79⁄16
911⁄16
79⁄16

Mounting
Dimensions
D
33
5413⁄16
33

E
13
14
20
13
14
20
13
14
20

Mounting
Screw
G
1⁄4
1⁄4
5⁄16
1⁄4
1⁄4
5⁄16
1⁄4
1⁄4
5⁄16

Conduit Size
K1
K2
1⁄2–3⁄4
11⁄4–11⁄2
1⁄2–3⁄4
11⁄4–11⁄2
2–21⁄2
11⁄4–11⁄2
—
—
—
—
—
—
—
—
—
—
—
—

E
20
241⁄4
20

Mounting
Screw
G
3
⁄8
3⁄8
3⁄8

Conduit Size
K1
K2
7⁄8–11⁄8
7⁄8–11⁄8
—
—
—
—

K3
1⁄2
1⁄2–3⁄4
1⁄2–3⁄4
—
—
—
—
—
—

K4
1⁄2–3⁄4
11⁄4–11⁄2
11⁄4–11⁄2
—
—
—
—
—
—

K5
11⁄4–11⁄2
11⁄2–2
2–21⁄2–3
—
—
—
—
—
—

Approx
Ship Wt
Lbs
20
57
93
20
57
93
20
57
93

K5
123⁄64–123⁄32
—
—

Approx
Ship Wt
Lbs
70
106
—

Class 84 Combination Type
Enclosure
Type

NEMA 1
NEMA 4/4X/12

Size
0–21⁄2
3–4
0–4

Outline Dimensions
Figure A
B
3
341⁄8
245⁄8
3
56
281⁄2
3
341⁄8
245⁄8

 Dimensions

may vary for size 3 & 4
stainless steel enclosures.

Siemens Industry, Inc.
Industrial Controls Catalog

 NEMA

K3
11⁄8–123⁄64
—
—

K4
11⁄8–123⁄64
—
—

4 Painted, 4X Stainless Steel.

8/127

Pump Control Panels

Class 81, 87, 88
Dimensions
Outline Drawings

Figure 2

Figure 1
F

Opening for
Conduit Hub
Size "P"

C

B
E

F

Figure 3
5.000

C

D
A

A

G

D

B
F

Mounting Hole
for 1/4" screw

C

F

E
B

6.000

Figure 4
DG

A

C

Mounting Hole
For 3/8" screw

H

B

K
L

Handle
(Optional)

A

L

L

M

Mounting Holes
For 5/16" Hardware

N

H
I
J

J

K

(4) .687 Dia Holes

D

F

G

E

Class 81 Pump Panel
Size

Figure

A

B

C

D

E

F

G

H

I

J

K

Conduit Knockout
L
M
N

25-50 Amp
>50 Amp

1
1

281/2
281/2

11
20

81/16
81/16

24
24

7
7

51/2
10

27
27

3
51/2

51/2
81/2

8
111/2

—
141/2

11/4 x 1
1/ x 3/
2
4

1/ x 3/
2
4
11/4 x 1

1/
2
3/
4

Hub
P
x 3/4
x1

11/2
11/2

Class 87 Standard and Vacuum Starter Pump Panel
Size

Figure

A

B

C

D

E

F

G

H

I

J

K

1 – 21/2
3–4
5
6
4 (Vac)

1
1
2
2
2

281/2
401/2
725/32
791/8
5531/32

20
24
20
22
243/8

81/16
83/32
10
1215/16
922/32

24
36
71
78
5426/32

—
—
16
18
201/4

10
12
21/8
21/8
21/8

27
39
7029/32
777/8
5423/32

51/2
87/16

81/2
1115/16

111/2
157/16

141/2
—

—

—

—

—

—

5

D
42 11/32
54 11/32
73 13/32
16

E
20
24
24
24 716

—

263/16

—

—

Conduit Knockout
L
M

Hub
P

N

1/ x 3/
11/4 x 1
2
4
131/32 x 215/32 7/8 x 11/8

3/
4

—

—

—

—

—

—

—

—

2714/32

—

—

—

—

x1

—

11/2
21/2

—

Class 88 Reduced Voltage Pump Panels
RVAT
Size
2–2 1/2
3–3 1/2
4
5, 6

Part Winding & Wye Delta
Fusible
Circuit
Disconnect Breaker
1–2
1–2 1/2
2 1/2–3 1/2
3–3 1/2
4
4
5, 6
5, 6

Figure
3
3
3
4

A
43 5/16
55 5/16
74 21/32
90

B
24 5/32
28 9/32
28 9/32
30

C
11
11
11
20

F
2 1/16
2 1/8
2 1/8
2 3/4

H
—
—
—
1 1/2

I
—
—
—
—

J
—
—
—
1 1/8

K
—
—
—
8 1/16

L
—
—
—
3

Note: Dimensions in inches (millimeters). Dimensions
for reference, not for construction. Contact Sales
Office for dimensions not listed.

8/128

Siemens Industry, Inc.
Industrial Controls Catalog

Lighting Contactors

LE, CLM, CM
Dimensions

Figure 2

Figure 1

Figure 3

Figure 4

Figure 5

G
K3
K2

K1

K2
K2

K2

K2

D

A

B

K2

K2

C

E
B

G

GA

C
K1

K2

K2

K3

E

K2

K3

D

Enclosed Class LE, CLM, CM

Non-Combination

without
CPT

NEMA 1

with CPT

without
CPT

NEMA
12/3R &
4/4X

with CPT

Mounting
Dimensions

Mtg
Screw

Conduit Size

C

D

E

G

K1

613⁄32

51⁄32

87⁄32

45⁄8

1

⁄4

1

1

1317⁄32
16

731⁄32
171⁄8

63⁄8
75⁄8

101⁄4
151⁄4

6
14

1

⁄4
1
⁄4

1

⁄2–3⁄4
1
⁄2–3⁄4

1

191⁄8

113⁄8

711⁄16

155⁄8

81⁄4

1

⁄4

200A (2-5p)
—
300–400A (2-5p)

1
5
2

247⁄8
26
48

133⁄8
175⁄8
20

81⁄8
121⁄2
121⁄2

213⁄4
253⁄16
453⁄16

9
151⁄2
10

1

⁄4
1
⁄4
1
⁄4

1

20A (2–12p),
30A (2–5p)

1

191⁄8

113⁄8

711⁄16

155⁄8

81⁄4

1

⁄4

30–60A (6–12p)
—
100-200A (2-5p)
300–400A (2-5p)
20A (2–12p),
30A (2–5p)
30A (6–12p)
60-100A (2-5p)
60A (6–12p)

3
1
5
2

16
247⁄8
26
48

171⁄8
133⁄8
175⁄8
20

75⁄8
81⁄8
121⁄2
121⁄2

151⁄4
213⁄4
253⁄16
453⁄16

14
9
151⁄2
10

1

⁄4
⁄4
1
⁄4
1
⁄4

1

1

1

5

16

13 ⁄4

1

6 ⁄8

15 ⁄4

3
5
2

16
16
19

171⁄8
13
22

75⁄8
91⁄2
8

151⁄4
151⁄8

—

5

26

131⁄8

79⁄16

200A (2-5p)
300–400A (3p)
20A (2–12p),
30A (2-5p)
30A (6-12p)

5
4

26
48

175⁄8
20

5

16

3

—
60-100A (2-5p)
60A (6-12p)
200A (3p)
300–400A (3p)

LE
Lighting
Rating

CLM
Lighting
Rating

Fig

A

B

20A (2–12p),
30–60A (3p)
—
—
30–60A (6–12p),
100A (3p)
—
200–400A (3p)
—
20A (2–12p),
30–60A (3–9p),
100A (3p)
—
30–60A (12p)
200–400A (3p)
—
20A (2–12p),
30-60A (3p)
—
—
—
30–60A (6–12p),
100A (3p)
200–400A (3p)
—
20A (2–12p),
30–60A (3p)
—
30–60A (6–12p),
100A (3p)
—
—
200–400A (3p)
—

30–60A (2-5p)

1

1031⁄32

20A (2–12p)
30–60A (6-12p)

1
3

100A (2-5p)

Outline Dimensions

K3

K4

K5

3

⁄4–1

—

—

3

⁄4–1
11⁄4–11⁄2

1–11⁄4
11⁄4–11⁄2

—
—

—
—

1

⁄2–3⁄4

1–11⁄4

11⁄2–2

—

—

⁄2–3⁄4
1
⁄2–3⁄4
2–21⁄2

11⁄4–11⁄2
11⁄4–11⁄2
11⁄4–11⁄2

21⁄2
11⁄4–11⁄2
1
⁄2–3⁄4

—
—
11⁄4–11⁄2

—
—
2–21⁄2

1

⁄2–3⁄4

1–11⁄4

11⁄2–2

—

—

⁄2–3⁄4
⁄2–3⁄4
—
2–21⁄2

11⁄4–11⁄2
11⁄4–11⁄2
11⁄4–11⁄2
11⁄4–11⁄2

11⁄4–11⁄2
2–21⁄2
11⁄4–11⁄2
1
⁄2–3⁄4

—
—
11⁄4–11⁄2

—
—
—
2–21⁄2

11

1

⁄4

—

—

—

—

—

14
11

1

⁄4
1
⁄4

—
—

—
—

—
—

—
—

—
—

251⁄4

10

1

⁄4

—

—

—

—

—

121⁄2
121⁄2

233⁄16
49

151⁄2
10

1

⁄4
1
⁄4

—
—

—
—

—
—

—
—

—
—

131⁄4

61⁄8

151⁄4

11

1

⁄4

—

—

—

—

—

16

171⁄8

75⁄8

151⁄4

14

1

⁄4

—

—

—

—

—

5

26

13 ⁄8

9

7 ⁄16

25 ⁄4

10

1

⁄4

—

—

—

—

—

5
2
5
4

16
19
26
48

13
22
175⁄8
20

91⁄2
8
121⁄2
121⁄2

151⁄8

11

1

⁄4

—

—

—

—

—

253⁄16
49

151⁄2
10

1

⁄4
⁄4

—
—

—
—

—
—

—
—

—
—

E

G

LE, CM
Combination

NEMA
with &
12/3R & without
4/4X
CPT

Type

Fusible and Non-fusible
Disconnect
Circuit Breaker

Siemens Industry, Inc.
Industrial Controls Catalog

1

1

1

1

1

⁄2

K2
⁄2–3⁄4

Outline Dimensions

Lighting Ratings Fig

A

B

C

20–60A
100A
200A
300A
20–100A

24
24
46
76
24

11
20
20
22
11

8
8
10
13
8

3
3
3
3
3

D

K1

K2

K3

8/129

Manual Control

Class 11 - 3RV, SMF, MMS
Wiring Diagrams
Signaling Contact
for Class 11 - 3RV

Class 11 - 3RV

Typical Wiring Diagrams—Class SMF

3RV1921-1M

Typical Wiring Diagrams—MMS

AC Reversing Manual Starter and
Manual Motor Starting Switches

L3

T3

L1

T1

L1

T2

L2

T2

L2

T3

L3

T3

L3

REV

FWD

COM

T1

REVERSING
SINGLE PHASE
3-LEAD
REPULSION-INDUCTION
MOTOR

Reversing Manual Motor
Starting Switch 2-Pole, 1-Phase

T1

L1
L3

T3

L1 L2 L3

L2

LOW

L1

L3

T3

Pilot Lights
(if used)

T1

L1

T1

T2

L2

T2

L2

T3

L3

T3

L3

Motor

Reversing Manual Starter
3-Pole, 3-Phase

L1

Pilot Lights
(if used)

2-SPEED
2-WINDING
SINGLE PHASE
MOTOR

Motor

LOW

HIGH

T12
T13
T1
T2
T3

T1

L1

Pilot Light
(if used)

Motor

L1
HIGH

LOW

L3

T3

REV
(R.H. UNIT)

COM

T1

L1

FWD
(L.H. UNIT)

HIGH

T1

L2

REV

T11

L1
FWD

AC 2-Speed Manual Motor Starting Switches

2-Pole, 1-Phase with
Pilot Lights

2-SPEED
2-WINDING WYE CONNECTED
3- PHASE
MOTOR

3-Pole, 3-Phase

3-Pole Reversing Switches
THREE PHASE MOTOR
LINE AND
MOTOR LEADS
Line

Meter

L1 to
L2 to
L3 to
T1 to
T2 to
T3 to

L.H.
UNIT

_
_
_

T1
T2
T3

_
_

Pilot Light
Leads to

T1 T2 T3

R.H.
UNIT
L1
L2
L3

_
_
_

T1
T3

SINGLE PHASE CAPACITOR
OR SPLIT PHASE MOTOR
L.H.
UNIT

LINE AND
MOTOR LEADS
Line

L1 to
L2 to

_
_

Meter

T1 to
T4 to
T5 to
T8 to

T1
T3
L1
T2

Furnish Jumper

L1
L2

_
_
_
_

L3 to

_
_

Pilot Light
Leads to

T8 T4

Motor

R.H.
UNIT

T2
T1
T3

T1 T5

SINGLE PHASE 4-LEAD
REPULSION - INDUCTION MOTOR
L.H.
UNIT

LINE AND
MOTOR LEADS
Line

L1 to
L2 to

_
_

Meter

T1 to
T4 to
T5 to
T8 to

T2
L3
T3
T1

Furnish Jumper

L3 to

_
_

Pilot Light
Leads to

T8

T1

R.H.
UNIT
L1
L2

_
_
_
_

T2
L1
T2

T5 T4

RUN
START

8/130

Siemens Industry, Inc.
Industrial Controls Catalog

Heavy Duty Motor Starters

Class 14

Wiring Diagrams
3-Phase and Single Phase Magnetic Starters
Single Phase Magnetic Starter, Size 00–1 햲햳

Three Phase Magnetic Starter, Size 00–4
TO SUPPLY
L2
L3

L1
TO PILOT
CONTROL DEVICE

IF PROVIDED

3

CONTROL FUSES
(OPTIONAL)

1
V

M

B

W

1

T1

T2
ESP200

95 96

A3+ A4-

XF

T3
C
97 98

3

W

M

96

1

XF

A1 ESP200 A3
95 96
97 98
A3+ A4-

C

SEC

H3

T1
MAY BE
GROUNDED BY
CUSTOMER

X1

H2

SEC

H1

T2

MOTOR

X2

MAY BE
GROUNDED BY
CUSTOMER

Solid State Overload 3-Phase Sizes 5-8

Three Phase Magnetic Starter with DC Coil, Sizes 00–4

TO PILOT
CONTROL DEVICE

SEC FUSE
H4

H3

X2

H1

MOTOR

CONTROL
TRANSFORMER
(OPTIONAL)

B

T2

T1

2

X1

H2

V

A

SEC FUSE
H4

CONTROL FUSES
(OPTIONAL)

1

CONTROL
TRANSFORMER
(OPTIONAL)

96

A

2

TO SUPPLY
L1
L2

IF PROVIDED

INCOMING LINE

POWER WIRING:
USE 75°C COPPER WIRE ONLY.

TO SUPPLY
L1
L2
L3

SIZE

CT RATIO

5

300:5

6

600:5

7

750:5

8

1200:5

A

B

C

CIRCUIT
PROTECTIVE
DEVICE
(IF USED)

CONTROL FUSES
(OPTIONAL)

1
IF PROVIDED

3

2

V

M

T1

B

W

T2

T3

LATE
BREAK
CONTACT

1

96 CONTROL
TRANSFORMER
(OPTIONAL)
XF
C

ESP200

95 96
97 98
A3+ A4-

H2
H3

X1

NOTE A

"A"

L1/1

SEC FUSE
H4

X1

2CT

3

L2
A1

L3
"C "

A2

REMOVE WIRE " C " IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.

CONTACTOR

M

2

SEC
X2

"B "

CURRENT
TRANSFORMER

H1

(WHEN USED, SEE TABLE)

RELAY

1CT

MAY BE
GROUNDED BY
CUSTOMER

MOTOR

2CT

X1

3CT

X1

(IF USED)
X1

95

O.L.

96

T1

T2

T3

NOTES:
A: 2CT IS LOCATED ON THE LINE SIDE
OF CONTACTOR ON SIZE 7 STARTERS ONLY.

Ambient Compensated
Single Phase Sizes 00-2 1/2

햲 Warning:

The ESP200 Starter and Single Phase Motor
must be wired as shown above. For L1, L2 do not use
the middle terminal or hole.

Siemens Industry, Inc.
Industrial Controls Catalog

Ambient Compensated
3-Phase Sizes 00-2 1/2

LOAD

Ambient Compensated
3-Phase Sizes 3-4

햳 Full

Load Amps (FLA): Adjustment of the ESP200 solid
state overload relay accommodates the single phase
motor.

8/131

Combination Heavy Duty Starters

Class 17, 18

Wiring Diagrams
3-Phase
Size 00–4 
TO PILOT
CONTROL DEVICE

IF PROVIDED

3

TO SUPPLY
L1
L2
L3
CONTROL FUSES
(OPTIONAL)

1
V

M

B

W

1

CONTROL
TRANSFORMER
(OPTIONAL)

96

A

2

T1
95 96

T2
ESP200

A3+ A4-

XF

T3
C
97 98

SEC FUSE
H4

H2
H3

X1
SEC
X2

H1

MOTOR

MAY BE
GROUNDED BY
CUSTOMER

Size 5–8 

SIZE

CT RATIO

5

300:5

6

600:5

7

750:5

8

1200:5

"C"

 Remove

wire “C” if control transformer is used. For
separate control voltage source, remove jumpers
“A” and “B” and connect source to control fuse line
terminals.

8/132

 Remove

wire “C” if the contactor coil is to operate
on a voltage other than line voltage or in a separate
control source.

Siemens Industry, Inc.
Industrial Controls Catalog

Reversing Heavy Duty Starters

Class 22

Wiring Diagrams
3-Phase Ambient Compensated Overload
Bimetal Overload
Sizes 0-1 3/4

Bimetal Overload
Sizes 2-2 1/2

Bimetal Overload
Sizes 3-4

Single Phase Ambient Compensated Overload

3-Wire, 2-Pole Sizes 0-1 3/4

Siemens Industry, Inc.
Industrial Controls Catalog

8/133

Reversing Heavy Duty Starters

Class 22

Wiring Diagrams
3-Phase Solid State Overload
3-Phase Reversing Magnetic Starter
Sizes 00–13⁄4

3-Phase Reversing Magnetic Starter
Sizes 2–4
TO SUPPLY

TO SUPPLY
L3
L1 L2

3
7

W

FOR

6

V REV W

CONTROL FUSES
(OPTIONAL)

2

CONTROL
TRANSFORMER
(OPTIONAL)

96

1
4
ESP200

A

95 96
97 98
A3+ A4-

C

T3

T2

T1

XF

B

V

SEC FUSE
H4

2
7

4
6

96 CONTROL
TRANSFORMER
(OPTIONAL)

1

W

REV

XF

C

T3

T2

T1

1
V

X2

H1

ESP200

95 96
97 98
A3+ A4-

B

A

MAY BE
GROUNDED BY
CUSTOMER

X2

H1

T1 MOTOR T3

X1
SEC

H3

SEC

H3

SEC FUSE
H4

H2

X1

H2

T2

W

FOR

CONTROL FUSES
(OPTIONAL)

5

3

1

5
V

L3

L2

L1

MOTOR

MAY BE
GROUNDED BY
CUSTOMER

Solid State Overload
Sizes 5–6
TO SUPPLY
L1

L2

L3
"REV"
CONTACTOR

"FWD"
"FWD"
CONTACTOR
CONTRACTOR

MECHANICAL
INTERLOCK

O.L.
RELAY

CURRENT
TRANSFORMER
(SEE TABLE)

REMOVE WIRE "C" IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.

MOTOR

3-Phase Reversing Magnetic Starter
with DC Coil, Sizes 00–13⁄4

3-Phase Reversing Magnetic Starter
with DC Coil, Sizes 2–4
L1

1
7

3

V

FOR

5

W

V

REV

T3

T2

T1

ESP200

LATE BREAK

6

B

T2
T1

MOTOR

96 CONTROL
TRANSFORMER
(OPTIONAL)
SEC FUSE
XF
H4
X1

C

H2
H3

T3

3 PHASE REVERSING

SEC

V

W

FOR

V

2
7

L.B.

T1

T2

4
6

XF

T3

X2
T2
T1

MOTOR

1
T3

W

L.B.

ESP200

H1
MAY BE
GROUNDED BY
CUSTOMER

REV

95 96
97 98
A3+ A4-

96

C

SEC FUSE
H4

H2
H3

CONTROL FUSES
(OPTIONAL)

B

8/134

NEMA 2 - 4

L3

5

CONTROL FUSES
(OPTIONAL)

4

95 96
97 98
A3+ A4-

L2

3

W

1
2

WIRING DIAGRAM

TO SUPPLY

TO SUPPLY
L2
L3

L1

X1

CONTROL
TRANSFORMER
SEC (OPTIONAL)
X2

H1
MAY BE
GROUNDED BY
CUSTOMER

Siemens Industry, Inc.
Industrial Controls Catalog

Combination Reversing Heavy Duty Starters

Class 25, 26

Wiring Diagrams
3-Phase

3-Phase Reversing Magnetic Starter
Sizes 00–13⁄4

3-Phase Reversing Magnetic Starter
Sizes 2–4

TO SUPPLY
L3
L1 L2

TO SUPPLY

3
FOR

7

W

6

V REV W

CONTROL FUSES
(OPTIONAL)

2

CONTROL
TRANSFORMER
(OPTIONAL)

96

1
4
ESP200

95 96
97 98
A3+ A4-

T1

T2

A

XF

B
C

T3

H2

FOR

T1

SEC FUSE
H4

H3
T2

V

W

T2

1
V

2
7

4
6

REV

96 CONTROL
TRANSFORMER
(OPTIONAL)

1

W

XF

C

T3

SEC FUSE
H4

H2
H3

X1

X1
SEC
X2

H1

ESP200

SEC

95 96
97 98
A3+ A4-

A

X2

H1

T1 MOTOR T3

CONTROL FUSES
(OPTIONAL)

5

3

1

5
V

L3

L2

L1

B

MAY BE
GROUNDED BY
CUSTOMER

MOTOR

MAY BE
GROUNDED BY
CUSTOMER

3 PHASE REVERSING

TO SUPPLY
L1

L2

Size 5–6

L3
"REV"
CONTACTOR

"FWD"
"FWD"
CONTACTOR
CONTRACTOR

MECHANICAL
INTERLOCK

O.L.
RELAY

CURRENT
TRANSFORMER
(SEE TABLE)

REMOVE WIRE "C" IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.

MOTOR

Siemens Industry, Inc.
Industrial Controls Catalog

8/135

Two Speed Heavy Duty Starters

Class 30 & 32 Non-Combination and Combination Starters
Wiring Diagrams

1 Winding Constant Horsepower Size 0–13/4
ELEMENTARY DIAGRAM

TO SUPPLY
L1

L2

DISCONNECT or
CIRCUIT BREAKER
HIGH
LOW

HIGH

LOW

T4

T2

LOW

T3
2

T5

1

96

CONTROL
TRANSFORMER
(OPTIONAL)

T6

T2
CONSTANT HORSEPOWER
MOTOR

3

6 LOW

5

7 HIGH

HIGH
4

B

7

2
ESP200
97 98
95 96

LOW

HIGH

8

T1

T2

XF

ESP200
97 98
95 96

A

A3+ A4-

95

CONTROL FUSES
(OPTIONAL)

1
V HIGH W

6

ALL OL'S
96

8

4

T1

T3

T1

OL
LOW LOW

3
V LOW W

T4

T5

LOW

A

5

T6

OL
HIGH HIGH

NEMA 00 - 1 3

WIRING DIAGRAM

TO SUPPLY
L1 L2 L3

L3

C

A3+ A4-

T3

T6

T4

SEC FUSE
H4

X1

H2

SEC

T5

H3

X2

H1

LOW
T1
T2
T3
T4
T5
T6

POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3 T4 T5 T6
HIGH SPEED T6 T4 T5

MAY BE
GROUNDED BY
CUSTOMER

MOTOR

1 Winding Constant Horsepower Size 2–4

5

1

V LOW W

A

2

B

1

96

CONTROL
TRANSFORMER
(OPTIONAL)
T6

T4

T5

XF

ESP200
95 96
97 98

A3+ A4-

T2

V L W
7

ESP200
95 96
97 98

CONTROL FUSES
(OPTIONAL)

3
6
VHIGHW

4

6

T1

NEMA 2 - 4

WIRING DIAGRAM

TO SUPPLY
L1 L2 L3

C

A3+ A4-

SEC FUSE
H4

X1

H2

SEC

T3

H3

X2

H1
T1
T2
T3
T4
T5
T6

MAY BE
GROUNDED BY
CUSTOMER

MOTOR

1 Winding Constant or Variable Torque Size 0–13/4
ELEMENTARY DIAGRAM

TO SUPPLY
L1

L2

L1

DISCONNECT or
CIRCUIT BREAKER
LOW
HIGH

LOW

HIGH

T2
T3

HIGH

T6

OL
HIGH HIGH

T4

HIGH

T5

ALL OL'S
96

L2

NEMA 0

L3

T4
T1

OL
LOW LOW

A

WIRING DIAGRAM

TO SUPPLY

L3

95

5

T3

T2
T5
T6
CONSTANT TORQUE MOTOR
T4
T3

2
LOW

5 LOW 7

4
HIGH
POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3
HIGH SPEED T6 T4 T5 T1 T2 T3

V HIGH W

CONTROL FUSES
(OPTIONAL)

1
V LOW W

4
6

B

7

T1

1

96

CONTROL
TRANSFORMER
(OPTIONAL)

2

T2
T5
T6
VARIABLE TORQUE MOTOR
3 HIGH 6

3
8

T1

LOW

8

ESP200
97 98
95 96

A

A3+ A4-

T6

T4

ESP200
97 98
95 96
A3+ A4-

T5

T1

T2

T3

XF

C

SEC FUSE
H4

X1

H2

SEC
H3

X2

H1

HIGH
T1
T2
T3
T4
T5
T6

MOTOR

MAY BE
GROUNDED BY
CUSTOMER

Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used.

8/136

Siemens Industry, Inc.
Industrial Controls Catalog

Two Speed Heavy Duty Starters

Class 30 & 32 Non-Combination and Combination Starters
Wiring Diagrams
1 Winding Constant or Variable Torque Size 2–4

TO SUPPLY
L1 L2 L3

DISCONNECT or
CIRCUIT BREAKER
LOW

T4
H

OL
LOW LOW

T1
T3

T2
H

LOW

T3

T4

HIGH

3 HIGH H

2

6

LOW
5 LOW 7

4

V LOW W
6

4

T2
T5
T6
VARIABLE TORQUE MOTOR

T5

HIGH

LOW

CONTROL FUSES
(OPTIONAL)

3

1

V HIGHW

T1

T3

ALL OL'S
95

5

T4

T6

OL
HIGH HIGH

96

T1

T2
T5
T6
CONSTANT TORQUE MOTOR

H

HIGH

A

NEMA 2 - 4

WIRING DIAGRAM

ELEMENTARY DIAGRAM

TO SUPPLY
L1 L2 L3

7

ESP200
95 96
97 98

A3+ A4-

A3+ A4-

T6

H

T1

ESP200
95 96
97 98

T4

1

96

CONTROL
TRANSFORMER
(OPTIONAL)

A

8

B

V H W
2

T2

T3

SEC FUSE

XF

C

H4

X1

H2

SEC

T5

H3

H
HIGH

X2

H1

POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3
HIGH SPEED T6 T4 T5 T1 T2 T3

T1
T2
T3
T4
T5
T6

MAY BE
GROUNDED BY
CUSTOMER

MOTOR

D68784002

2 Winding Constant Horsepower & 2 Winding Constant or Variable Torque Size 0–4

TO SUPPLY
L1 L2 L3

L2

L3

DISCONNECT or
CIRCUIT BREAKER

LOW

HIGH

A

T3

V HI

2

T13

7

B

6

1

CONTROL
TRANSFORMER
(OPTIONAL)

96

T12
XF

T11
T13
TWO WINDING MOTOR

ESP200
95 96
97 98

A

A3+ A4-

95

W

4

T12

ALL OL'S

POSITION L1 L2 L3
LOW SPEED T1 T2 T3
HIGH SPEED T11 T12 T13

V LO W

T1

T11

OL
HIGH

HIGH

96

8

T2
T3

CONTROL FUSES
(OPTIONAL)

1

T1

OL
LOW

LOW

HIGH

5

3

T2

LOW

NEMA 2 - 4

WIRING DIAGRAM

TO SUPPLY
L1

ELEMENTARY DIAGRAM

5 LOW 6

4
HIGH

3 HIGH 7

2
LOW

HIGH

ESP200
95 96
97 98
A3+ A4-

C

SEC FUSE
H4

SEC

8
T1

T2

T3

T11

T12

X1

H2

T13

H3
X2
H1

LOW
T1
T2
T3
T11
T12
T13

MOTOR

MAY BE
GROUNDED BY
CUSTOMER

D68786001

Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used.

Siemens Industry, Inc.
Industrial Controls Catalog

8/137

Reduced Voltage Starters & Pump Panels

Class 36, 37, 88
Wiring Diagrams
Part Winding

EMT

8/138

Siemens Industry, Inc.
Industrial Controls Catalog

Reduced Voltage Starters & Pump Panels

Class 36, 37, 88
Wiring Diagrams

Auto Transformer
TO SUPPLY
L1 L2 L3
SEK
SES
SAW
LMB

SEK
SES
SAW
LMB

SEK
SES
SAW
LMB

OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER

OL

1S

3L1
0%

50%

1L1

R

65%

1CT

80%

2S

L2 L3

100%

L1

T1

2L1

OL

0%

50%

65%

80%

R

1S

3L2

1L2
100%

2S
2CT

*

T2

2L2

FOR MOTOR
HP SEE
CONTROLLER
NAMEPLATE

MOTOR

OL

4FU

71

MR

73

1S

0%

50%

65%

3L3
80%

R

FOR STARTER
SIZES 1-4, 1CT-3CT
ARE NOT USED.

L1

1L3
100%

2S
3CT

T3

2L3

1S

74

(A1)

R

75

(A2)

2S

76

MR

5FU

72

L2

2S

CR1

77

(A1)

(A2)

1S

*
CR1

L1

79

H1

MECH
INTLK

(A1)

(A2)

R

H4

3FU

L2

CPT

X2

X1
CONNECT
VOLTAGE
AS SPECIFIED
PER NAMEPLATE

NOTE E

2

3

2

LMB
SAW
SES
SEK

1

X2

TR

SUPPLIED AS REQUIRED

3

LMB
SAW
SES
SEK

JUMPER

1FU

12

TAS

1

2FU

78

1S

(A1)

(A2)

MR

4

(95)

OL

(96)

3

MR

TR

6

(A1)

(A2)

CR1
NOTC

CONNECTIONS FOR OPTIONAL DEVICES

Note E:
Remove jumper if thermal
protection switch is provided.

HAND

*

2

3

1PB
OFF
AUTO

(A2)

(A1)
CR2

(A2)

3
2PB

5
1SS

HAND

AUTO
CONTACT

*

3

4

ETM

OFF
AUTO

1

RUN/ON/
RUNNING

3

4

3

5
1

(A1)

2PB
START

2

1

1

*

SURGE SUPPRESSOR

START

STOP
1

1SS

*

OFF

1LT

AUTO
CONTACT

OL

OL TRIPPED
9
X2

MR

OFF/STOP
X2
10

1

4LT

ON

1
1SS

*

3

1

5LT

OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS

Siemens Industry, Inc.
Industrial Controls Catalog

8/139

Reduced Voltage Starters & Pump Panels

Class 36, 37, 88
Wiring Diagrams

Wye Delta (Open Transition)
TO SUPPLY
L1 L2 L3
OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER

OL

1L1

1M

T1

2M

T6

1M

T2

T1

1CT

T6

OL

1L2

T1

T6

T2

S

2CT

S

S

2M

T3

T4

T4

S
T5

1M

1L3

T4

T5

OL

T2

T3

T3

3CT

2M

T5

FOR STARTER
SIZES 1-4, 1CT-3CT
ARE NOT USED.

1L1

1L2

4FU

50

MR

2M

51

CR1

52

53

(A1)

54

(A2)

MR

55

S
S

S

56

57

*

5FU

MECH

(A1)

(A2)

INTERLOCK

2M
1M
(A1)

(A2)

1M

SUPPLIED AS REQUIRED
3FU

2FU
H1

1FU

1

H3 H2

H4

CPT
1X1

X1

X2

CONNECT
VOLTAGE
AS SPECIFIED
PER NAMEPLATE

X2

TR

1

3

2

2

MR

(A1)

TR

3

OL

4

(A2)

MR

(A1)

6

X2

(96)

(95)

(A2)

CR1

NCTO

CONNECTIONS FOR OPTIONAL DEVICES

2

3

CR2

(A2)

3
2PB

5

1

1SS

HAND

*

(A2)

(A1)

START

2

1

(A1)

2PB

1PB
OFF
HAND
AUTO

*

SURGE SUPPRESSOR

START

STOP
1

AUTO
CONTACT

*

3

4

ETM

OFF
AUTO

1

RUN/ON/
RUNNING

3
3

4

1LT

AUTO

5 CONTACT
1

1SS

*

OL

OL TRIPPED
9
X2

MR

OFF/STOP
10
X2

1

4LT

ON

OFF
1
1SS

*

3

1

5LT

OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS

8/140

Siemens Industry, Inc.
Industrial Controls Catalog

Reduced Voltage Starters & Pump Panels

Class 36, 37, 88
Wiring Diagrams

Wye Delta (Closed Transition)
TO SUPPLY
L1 L2 L3
OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER

OL

1M

T1

T1

1CT

1L1

3L1

RES A

1A

2M
T6

OL

1M

1L2

3L2

2CT
RES B

T1

T6

T2

T2

S

1A

S

S

2M

T3

T4

S
T5

1M

1L3

T4

T5

OL

T3

T3

3CT

3L3

RES C

2M

T2

1A

FOR STARTER
SIZES 1-4, 1CT-3CT
ARE NOT USED.

1L2

1L1
4FU

50

MR

2M

51

CR1

52

53

(A1)

(A2)

MR

54

55

5FU

1A
1A

S

S

57

56

(A1)

58

(A1)

(A2)

S

*

MECH
(A2)

INTERLOCK

2M

1M
(A1)

(A2)

1M
SUPPLIED AS REQUIRED

3FU

2FU
H1

1FU

1

H3 H2

H4

CPT
1X1

X1

X2

TR

6

CONNECT
VOLTAGE
AS SPECIFIED
PER NAMEPLATE

X2

(A1)

(A2)

CR1

NCTO

TR

1

3

2

2

MR

(A1)

MR

4

(A2)

OL
(96)

(95)

X2

3

CONNECTIONS FOR OPTIONAL DEVICES

2

3

1PB
OFF
HAND
AUTO

*

(A2)

START

(A1)

CR2

(A2)

3
2PB

5
1SS

HAND

AUTO
CONTACT

*

3

4

ETM

OFF
AUTO

1

RUN/ON/
RUNNING

3
3

5
1

(A1)

2PB

2

1

1

*

SURGE SUPPRESSOR

START

STOP
1

1SS

*

OFF

4

1LT

AUTO
CONTACT

OL

OL TRIPPED
9
X2

MR

OFF/STOP
10
X2

1

4LT

ON

1
1SS

*

3

1

5LT

OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS

Siemens Industry, Inc.
Industrial Controls Catalog

8/141

Heavy Duty Contactors and Reversing Contactors

Class 40, 43

Wiring Diagrams
3-Phase Magnetic Contactors and Reversing Contactors
3-Phase Contactors—Size 00–4

3-Phase Reversing Contactors—Size 00–4

3-Phase Contactors—Size 5, 6

3-Phase Reversing Contactors—Size 5, 6
TO SUPPLY
L1

L2

L3
"REV"
CONTACTOR

"FWD"
"FWD"
CONTACTOR
CONTRACTOR

MECHANICAL
INTERLOCK

RELAY

CURRENT
TRANSFORMER

REMOVE WIRE "C" IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.

LOAD

Single Phase Magnetic Contactors and Reversing Contactors
Single Phase Contactors—Size 00–4

8/142

Single Phase Reversing Contactors—Size 00–1P

Siemens Industry, Inc.
Industrial Controls Catalog

Duplex Heavy Duty Controllers

Class 83, 84

Wiring Diagrams
Standard Duplex Pump Panel (92)

Siemens Industry, Inc.
Industrial Controls Catalog

Duplex Panel w/o alternator (95)

8/143

Duplex Heavy Duty Controllers

Class 83, 84

Wiring Diagrams
Duplex Panel with Relay Alternation (93)

8/144

Duplex Panel with Lead Pump Transfer Switch (94)

Siemens Industry, Inc.
Industrial Controls Catalog

Standard & Irrigation Pump Panels

Class 81, 87

Wiring Diagrams
Standard Class 87 Pump Panel

Irrigation Class 81 Pump Panel

Siemens Industry, Inc.
Industrial Controls Catalog

8/145

Lighting and Heating Contactors

Electrically Held, Class LE
Wiring Diagrams
20 AMP

30 – 100 AMP

200 – 400 AMP

8/146

Siemens Industry, Inc.
Industrial Controls Catalog

Lighting and Heating Contactors

Mechanically Latched 20 Amp, Class CLM
Wiring Diagrams

ON

OFF
CONTACTOR CONTROL
VOLTAGE

L

OFF

L
ON

C
0

COMMON OR SEPARATE
CONTROL LINES

5

ON

OFF

CONTROL
MODULE
VOLTAGE

OFF

2

CR1

3

CR2

L
CR2

CR1

0

CR1

CR2

C

4

TYPICAL OFF-ON
SELECTOR SWITCH

ON

COIL
PILOT LIGHTS
REQUIRE (1) EA.
CLM4097291
AUXILIARY
CONTACT KIT.

3 WIRE CONTROL ACC. 48

ON
CONTACTOR CONTROL
VOLTAGE
HAND

OFF

AUTO

OFF

5

CONTROL
MODULE
VOLTAGE

CR

CR

4

0
C

OFF

5

CR2

2

CONTROL
MODULE
VOLTAGE

COIL

REMOTE
CONTROL

3

OFF

L
CR

3

L

CONTACTOR CONTROL
VOLTAGE

L

CR1

CR2

L
CR1

0

CR1

C

4

COIL

ON

ON

ON-OFF (FORM 3) CONTROL ACC. 49

2 WIRE CONTROL ACC. 47

CONNECTIONS TO CONTROL MODULES
CONTACTOR CONTROL
VOLTAGE
OFF

5

L

ON-OFF
CONTROL
MODULE
VOLTAGE

3
CR
4

CR

0

CR

C

COIL

ON

2 WIRE CONTROL ACC. 47

Siemens Industry, Inc.
Industrial Controls Catalog

MODULE
TERMINAL

L

1
2

CONNECT TO:
NOT USED
CONT. STATION FOR ACC. 48 & 49

3

CONT. STATION FOR ACC. 47,48 & 49

4

MODULE CONTROL VOLTAGE *

5

CONTACTOR CONTROL VOLTAGE

O

" CONTACTOR
"
TERMINAL O ON

C

" CONTACTOR
"
TERMINAL C ON
* FOR 24 VDC CONTROL MODULES
CONNECT TERMINAL 4 TO NEGATIVE (-)

8/147

Lighting and Heating Contactors

Mechanically Latched 30–40 Amps, Class CLM
Wiring Diagrams
Mechanically Latched, CLM 30–200 Amps

Connection Diagram for Common/Separate
Control with Momentary Pushbutton or
ON-OFF Selector Switch CLMOC, CLMOD,
CLMOE, and CLMOF

Connection for 2-Wire Control CLMOC,
CLMOD, CLMOE, and CLMOF

Connection for Hand/Off/Auto Control
CLMOC, CLMOD, CLMOE, and CLMOF

Mechanically Latched Type CLM 300 and 400 Amp

Connection Diagram for Common/Separate
Control with Momentary Pushbutton or
ON-OFF Selector Switch CLMOG and
CLMOH

Connection for 2-Wire Control CLMOG and
CLMOH

Connection for Hand/Off/Auto Control
CLMOG and CLMOH

 Control

relay is required for 2-wire and Hand/Off/Auto
Control, as shown in diagram.

8/148

Siemens Industry, Inc.
Industrial Controls Catalog

Industrial Control Power Transformers

Class MT, MTG
Wiring Diagrams

Voltage Letter
A햲햴

Voltage Letter
B햳 햴

Voltage Letter
C햳 햴

When secondary fuse clips are installed,
Terminal X1 becomes XF

When secondary fuse clips are installed,
Terminal X1 becomes XF

Voltage Letter
D햳

Voltage Letter
E햲 햴

When secondary fuse clips are installed,
Terminal X1 becomes XF

When secondary fuse clips are installed,
Terminal X1 becomes XF

Voltage Letter
G햲

Voltage Letter
H

Voltage Letter
I

When secondary fuse clips are installed,
Terminal X1 becomes XF

Does not include secondary fuse clips

Does not include secondary fuse
clips

Voltage Letter
J 햳햴

Voltage Letter
L

Voltage Letter
M햲

When secondary fuse clips are installed,
Terminal X3 becomes XF

Does not include secondary fuse clips

When secondary fuse clips are
installed, Terminal X1 becomes XF
Voltage Letter
F햲

When secondary fuse clips are
installed, Terminal X1 becomes XF

When secondary fuse clips are
installed, Terminal X1 becomes XF

Voltage Letter
P
H1

햲
햳
햴

Includes secondary fuse clips on sizes 50-750VA
Includes secondary fuse clips on sizes 50-500VA
Secondary fuse clips are not included on MTG
transformers.

Siemens Industry, Inc.
Industrial Controls Catalog

X2

380V

24V

H2

X1

Does not include secondary fuse clips

8/149

Overload Relay Heater Tables

Selection of Heater Elements for Overload Relays
General
Use only when motor full load
current is not known. Motor amps
will vary depending on the type and
manufacturer of the motor. These
average values, for motors with service
factor of 1.15, are to be used only as a
guide. The formulas at the bottom of the
page may be used to obtain approximate
amps for other motors.
Note: RPM shown for 60 cycle motors.
For 50 cycle motors, multiply RPM by .83.

CAUTION: Actual motor amps may be
higher or lower than the values listed
below for a particular motor. For more
reliable motor protection, select heater
elements by using the full load motor
nameplate amps.
Single Phase motor full load amps of
the same horsepower, voltage and speed
vary over wide ranges. The following
table conforms with table 430.148 of
the NEC.

3-Phase

1

⁄4

1

⁄3

1

⁄2

3

⁄4

1

11⁄2

2

3

5

71⁄2

10

15

20

50 Hz

Syn
Speed
RPM

200
Volts

230
Volts

460
Volts

575
Volts

1800
1200
900
1800
1200
900
1800
1200
900
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900

1.09
1.61
1.84
1.37
1.83
2.07
1.98
2.47
2.74
2.83
3.36
3.75
3.22
4.09
4.32
4.95
5.01
5.59
6.07
6.44
6.44
7.36
7.87
9.09
9.59
10.8
11.7
13.1
15.5
16.6
18.2
18.3
22.4
24.7
25.1
26.5
29.2
30.8
32.2
35.1
41.9
45.1
47.6
51.2
58.0
58.9
60.7
63.1

0.95
1.40
1.60
1.19
1.59
1.80
1.72
2.15
2.38
2.46
2.82
3.26
2.80
3.56
3.76
4.30
4.36
4.86
5.28
5.60
5.60
6.40
6.84
7.90
8.34
9.40
10.2
11.4
13.5
14.4
15.8
15.9
19.5
21.5
21.8
23.0
25.4
25.8
28.0
30.5
36.4
39.2
41.4
44.5
50.4
51.2
52.8
54.9

0.48
0.70
0.80
0.60
0.80
0.90
0.86
1.08
1.19
1.23
1.46
1.63
1.40
1.78
1.88
2.15
2.18
2.43
2.64
2.80
2.80
3.20
3.42
3.95
4.17
4.70
5.12
5.70
5.76
7.21
7.91
7.92
9.79
10.7
10.9
11.5
12.7
13.4
14.0
15.2
18.2
19.6
20.7
22.2
25.2
25.6
26.4
27.4

0.38
0.56
0.64
0.48
0.64
0.72
0.69
0.86
0.95
0.98
1.17
1.30
1.12
1.42
1.50
1.72
1.74
1.94
2.11
2.24
2.24
2.56
2.74
3.16
3.34
3.76
4.10
4.55
5.41
5.78
6.32
6.33
7.81
8.55
8.70
9.19
10.1
10.7
11.2
12.2
14.5
15.7
16.5
17.8
20.1
20.5
21.1
21.9

Formula—Approximate Full Load Amps
for Other Motors
208 Volt Full Load Amp 앒 230 Volt current ҂ 110%
2-Phase FLA 앒 0.866 ҂ the 3-Phase FLA
2-Phase, 3-wire current in common wire 앒 1.41 ҂ that in
the other 2 lines

8/150

Full Load Current (60Hz)
Hp
1

⁄8
1
⁄4
1
⁄3
1
⁄2
3
⁄4
1
1 1⁄2
2
3
5
7 1⁄2
10

115 Volts

230 Volts

4.4
5.8
7.2
9.8
13.8
16
20
24
34
56
80
100

2.2
2.9
3.6
4.9
6.9
8
10
12
17
28
40
50

3-Phase
Full Load Current (60Hz)

Hp

1-Phase

380
Volts

0.55
0.81
0.93
0.64
0.92
1.04
0.99
1.24
1.38
1.42
—
1.88
1.70
2.06
2.28
2.60
2.69
2.94
3.20
3.39
3.39
3.84
4.14
4.77
5.02
5.70
6.20
6.80
8.20
8.74
9.59
9.60
11.50
13.00
13.20
13.90
15.40
16.30
16.90
18.50
22.00
23.70
25.00
26.90
30.50
31.00
31.90
33.20

Full Load Current (60Hz)

Hp

25

30

40

50

60

75

100

125

150

200

250

300
400

50 Hz

Syn
Speed
RPM

200
Volts

230
Volts

460
Volts

575
Volts

380
Volts

3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
1800
1200
1800

69.9
74.5
75.4
77.4
84.8
86.9
90.6
94.1
111
116
117
121
138
143
145
150
164
171
173
177
206
210
212
222
266
271
275
290
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

60.8
64.8
65.6
67.3
73.7
75.6
78.8
81.8
96.4
101
102
105
120
124
126
130
143
149
150
154
179
183
184
193
231
236
239
252
292
293
298
305
343
348
350
365
458
452
460
482
559
568
573
600
278
684
896

30.4
32.4
32.8
33.7
36.8
37.8
39.4
40.9
48.2
50.4
50.6
52.2
60.1
62.2
63.0
65.0
71.7
74.5
75.0
77.0
89.6
91.6
92.0
96.5
115
118
120
126
146
147
149
153
171
174
174
183
229
226
230
241
279
284
287
300
339
342
448

24.3
25.9
26.2
27.0
29.4
30.2
31.5
32.7
38.5
40.3
40.4
41.7
48.2
49.7
50.4
52.0
57.3
59.4
60.0
61.5
71.7
73.2
73.5
77.5
92.2
94.8
95.6
101
116
117
119
122
137
139
139
146
184
181
184
193
223
227
229
240
271
274
358

36.80
39.20
39.60
40.70
—
45.70
47.60
49.50
—
61.00
61.20
63.20
—
75.20
76.20
78.50
—
90.00
91.10
93.10
—
111.00
112.00
117.00
—
144.00
145.00
153.00
—
177.00
180.00
186.00
—
210.00
210.00
211.00
—
274.00
276.00
279.00
—
343.00
345.00
347.00
392.00
395.00
—

25Hz 1500 RPM, amps 앒 amps of 60Hz, 3600 RPM
25Hz 750 RPM, amps 앒 amps of 60Hz, 1800 RPM
Service factor 1.0 앒 amps ҂ 0.9
50°C–55°C motor 앒 amps ҂ 0.9

Siemens Industry, Inc.
Industrial Controls Catalog

Overload Relay Heater Tables

Selection of Heater Elements for Overload Relays
General
To Select Heater Catalog Number Use

2. Refer to the specified table and use

▪
▪
▪
▪

the controller size and motor amps to
select the heater catalog number.
a. If motor amps are not known, an
approximate value may be found on
the previous page. These values
should be used with caution and only
when motor amps are not available.
Heaters shown on the following pages
provide a maximum trip rating of 125%
of minimum motor amperes for 40˚C
motors (service factor 1.15). For other
motors (service factor 1.0), select the
next lower listed heater catalog number
within the designated table which
provides a maximum trip rating of
approximately 115%.

Product Class
Controller Size
Motor Amp
Phase
Catalog No 14 C P 3 2 B C 81
Phase
Size
Class

1. Find heater table number below,

using the Product Class, Controller
Size and Phase. Heater table number
is found in the column under the type
of overload and phase.

Overload relays do not provide
protection against short circuits.
To ensure proper coordination with
short circuit protective device, select
heaters from the information packaged
with the control device.

Heater Table Number

Size
or
Amperage

Controller
Size
Letter

Bimetal Standard Trip (Class 20)

Bimetal Quick Trip (Class 10)

Compensated
E Heaters
Green Reset

Compensated
K Heaters
Green Reset

Class

Description

SMF

Manual

All

—

14, 22

Magnetic
Non-reversing,
Reversing

00-4

B–J

213

233

313

332

0-4

C-J

—

233

—

332

25-180A

D–J

216

238

316

335

17, 18
25, 26
30, 32
83, 84
87, 89
48

Combination
Reversing Combination
Multi Speed
Pump Controllers
Motor Control Centers
Panel Mounted
Overload Relay

1Ph

3Ph

1Ph

3Ph

See Page 8/152

ESP200 starters do not require heater elements.
 Overload

Relay Selection Multi-Speed
Each speed requires a separate set of overloads. The
adjustment range must be selected on the basis of the
full-load current for each particular speed.

Siemens Industry, Inc.
Industrial Controls Catalog

8/151

Manual Control

Heater Elements, Class SMF
General
Ordering Information
1. Determine number of heater elements required from Table A.
2. Determine motor full load current and service factor.
NOTE: If motor amps are unknown, an approximate value may be found on page 8/150. These values
should be used with caution and only when motor amps are not available.

3. If the motor and controller are in the same ambient temperature:
a. For 1.15 to 1.25 service factor motors use 100% of motor full load current for heater element selection.
b. For 1.0 service factor motors use 90% of motor full load current for heater element selection.
c. Heater elements are class 20.
Heater Elements Class SMF

4. If the motor and controller are in different ambient temperatures multiply motor full load current by the multiplier in
Table B. Use the resultant full load current for heater element selection.
5. Select proper heater element from table below.
6. All tables are based on the operation of the motor and controller in the same ambient temperature, 40°C (104°F) or
less. Always be certain the correct heater element is installed in the starter before operating the motor.

Heater
Catalog Number

Motor Full-Load
Current (Amps)

SMFH01
SMFH02
SMFH03
SMFH04
SMFH05
SMFH06
SMFH07
SMFH08
SMFH09
SMFH10
SMFH11
SMFH12
SMFH13
SMFH14
SMFH15
SMFH16
SMFH17
SMFH18
SMFH19
SMFH20
SMFH21
SMFH22
SMFH23
SMFH24
SMFH25
SMFH26

0.157–0.173
0.174–0.192
0.193–0.212
0.213–0.235
0.236–0.261
0.262–0.289
0.290–0.321
0.322–0.355
0.356–0.399
0.41–0.44
0.45–0.49
0.50–0.53
0.54–0.58
0.59–0.65
0.66–0.71
0.72–0.78
0.79–0.85
0.86–0.96
0.97–1.04
1.05–1.16
1.17–1.25
1.30–1.39
1.38–1.54
1.48–1.63
1.57–1.75
1.66–1.86

List
Price $

Table A
Number of Heater Elements
Device

SMFF*1
SMFF*2
SMFF*3
SMFF*4
SMFF*5
SMFF*6
SMFF*22
SMFF*44
SMFF*11
SMFF*22

8/152

Number of
Heater Elements

1

2
2

Heater
Catalog Number

Motor Full-Load
Current (Amps)

SMFH27
SMFH28
SMFH29
SMFH30
SMFH31
SMFH32
SMFH33
SMFH34
SMFH35
SMFH36
SMFH37
SMFH38
SMFH39
SMFH40
SMFH41
SMFH42
SMFH43
SMFH44
SMFH45
SMFH46
SMFH47
SMFH48
SMFH49
SMFH50
SMFH51
SMFH52

1.80–1.99
1.96–2.15
2.16–2.38
2.39–2.75
2.76–2.84
2.85–3.06
3.07–3.45
3.46–3.70
3.71–4.07
4.08–4.32
4.33–4.90
4.91–5.35
5.36–5.85
5.86–6.41
6.42–6.79
6.80–7.57
7.58–8.15
8.16–8.98
8.99–9.67
9.68–9.95
9.96–10.8
10.9–12.1
12.2–13.1
13.2–13.9
14.0–15.0
15.1–16.0

List
Price $

Table B—Special Applications
Heater Element Selection
Notes

Ambient Temperature of Motor

All single pole and two pole SMF
starters require only 1 Heater
Element.

Same as
Controller
Ambient

Duplex Unit. One Heater Element
per starter.
Two Speed Starter. One Heater
Element per speed.

Continuous
Duty Motor
Service Factor

1.15 to 1.25
1.0

Product Category: NEMA

Constant 10°C
(18°F) Higher
Than Controller
Ambient

Constant 10°C
(18°F) Lower
Than Controller
Ambient

Full Load Current Multiplier

1.0
0.9

0.9
0.8

1.05
0.95

Siemens Industry, Inc.
Industrial Controls Catalog

Overload Relay Heater Tables

Full Load Motor Amps, Single Phase, Trip Class 20 – Tables 213, 216
Selection
Table 213 for Class 14, 22 (1-Phase)
Full Load Amps

Siemens Industry, Inc.
Industrial Controls Catalog

Size 00, 0, 1 Size 1P

Size 2, 21⁄2

Heater
Catalog No

0.37–0.40
0.41–0.44
0.45–0.47
0.48–0.52
0.53–0.57
0.58–0.62
0.63–0.69
0.70–0.74
0.75–0.81
0.82–0.85
0.86–0.93
0.94–1.03
1.04–1.11
1.12–1.22
1.23–1.34
1.35–1.53
1.54–1.71
1.72–1.92
1.93–2.12
2.13–2.24
2.25–2.43
2.44–2.57
2.58–2.86
2.87–3.16
3.17–3.35
3.36–3.58
3.59–3.90
3.91–4.25
4.26–4.77
4.78–5.35
5.36–5.76
5.77–6.33
6.34–6.98
6.99–7.37
7.38–7.71
7.72–8.51
8.52–9.31
9.32–10.1
10.2–10.9
11.0–12.2
12.3–13.5
13.6–15.7
15.8–17.3
17.4–19.9
20.0–21.7
21.8–23.4
23.5–24.0
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
19.4–22.0
22.1–23.5
23.6–25.0
25.1–27.0
27.1–28.9
29.0–31.0
31.1–34.8
34.9–36.9
37.0–43.9
44.0–46.0
46.1–48.3
48.4–55.0
55.1–60.0

E3
E4
E5
E6
E7
E8
E9
E11
E12
E13
E14
E16
E17
E18
E23
E24
E26
E27
E28
E29
E31
E32
E33
E34
E36
E37
E38
E39
E41
E42
E44
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56
E57
E60
E61
E62
E65
E66
E67
E69
E70
E72
E73
E74
E76

—
0.41–0.44
0.45–0.47
0.48–0.52
0.53–0.57
0.58–0.62
0.63–0.69
0.70–0.74
0.75–0.81
0.82–0.85
0.86–0.93
0.94–1.03
1.04–1.11
1.12–1.22
1.23–1.34
1.35–1.53
1.54–1.71
1.72–1.92
1.93–2.12
2.13–2.24
2.25–2.43
2.44–2.57
2.58–2.86
2.87–3.16
3.17–3.35
3.36–3.58
3.59–3.90
3.91–4.25
4.26–4.77
4.78–5.35
5.36–5.76
5.77–6.33
6.34–6.98
6.99–7.37
7.38–7.71
7.72–8.51
8.52–9.31
9.32–10.1
10.2–10.9
11.0–12.2
12.3–13.5
13.6–15.7
15.8–17.3
17.4–19.9
20.0–21.7
21.8–23.4
23.5–23.7
23.8–25.1
25.2–27.9
28.0–32.2
32.3–34.0
—
—
—
—

Table 216 for Class 48
Full Load Amps
List Price $

Product Category: NEMA

48DA, 48GA 48HA

48JA

Heater
Catalog No

0.34–0.36
0.37–0.40
0.41–0.43
0.44–0.47
0.48–0.51
0.52–0.56
0.57–0.62
0.63–0.67
0.68–0.73
0.74–0.77
0.78–0.84
0.85–0.93
0.94–1.00
1.01–1.10
—
1.11–1.21
1.22–1.38
1.39–1.54
1.55–1.73
1.74–1.91
1.92–2.02
2.03–2.19
2.20–2.32
2.33–2.58
2.59–2.85
2.86–3.02
3.03–3.23
3.24–3.52
3.53–3.83
3.84–4.30
4.31–4.82
4.83–5.19
5.20–5.71
5.72–6.29
6.30–6.64
6.65–6.95
6.96–7.67
7.68–8.39
8.40–9.19
9.20–9.94
9.95–10.9
11.0–12.2
12.3–14.2
14.3–15.6
—
15.7–17.9
18.0–19.6
19.7–22.3
22.4–24.0
24.1–25.9
26.0–29.5
29.6–32.5
32.6–33.5
33.6–36.9
37.0–39.2
39.3–43.1
43.2–47.4
47.5–50.0
50.1–55.2
55.3–60.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
50.0–55.9
56.0–60.9
61.0–65.9
66.0–69.9
70.0–75.9
76.0–81.9
82.0–86.9
87.0–92.9
93.0–97.9
98.0–107.9
108.0–113.9
114.0–125.0
126.0–138.0
139.0–153.0
154.0–163.0
164.0–180.0

E3
E4
E5
E6
E7
E8
E9
E11
E12
E13
E14
E16
E17
E18
E19
E23
E24
E26
E27
E28
E29
E31
E32
E33
E34
E36
E37
E38
E39
E41
E42
E44
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56
E57
E59
E60
E61
E62
E65
E66
E67
E69
E70
E71
E72
E73
E74
E76
E77
E78
E79
E80
E88
E89
E91
E92
E93
E94
E96
E97
E98
E99
E101
E102
E103
E104
E106
E107

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
27.1–30.0
30.1–33.2
33.3–35.7
35.8–39.4
39.5–43.4
43.5–46.9
47.0–51.5
51.6–57.0
57.1–62.8
62.9–69.1
69.2–75.0
75.1–83.3
—
—
—
—
—
—
83.4–86.9
87.0–92.9
93.0–100.0
—
—
—
—
—
—
—

List Price $

8/153

Overload Relay Heater Tables

Full Load Motor Amps, 3-Phase, Trip Class 20 – Tables 233, 238
Selection
Table 233 for Class 14, 17, 18, 22, 25, 26, 30, 32, 83, 84, 87 (3-Phase)
Full Load Amps
Size 00, 0, 1 Size 13⁄4

Size 2, 21⁄2

Size 3, 31⁄2

Size 4

Heater
Catalog No

0.38–0.40
0.41–0.43
0.44–0.48
0.49–0.53
0.54–0.57
0.58–0.62
0.63–0.66
0.67–0.72
0.73–0.80
0.81–0.85
0.86–0.92
0.93–0.99
1.00–1.08
1.09–1.23
1.24–1.37
1.38–1.54
1.55–1.69
1.70–1.80
1.81–1.94
1.95–2.07
2.08–2.26
2.27–2.54
2.55–2.69
2.70–2.88
2.89–3.14
3.15–3.40
3.41–3.81
3.82–4.26
4.27–4.62
4.63–5.09
5.10–5.61
5.62–5.91
5.92–6.15
6.16–6.70
6.71–7.54
7.55–8.29
8.30–8.99
9.00–9.85
9.86–10.4
10.5–12.0
12.1–13.6
13.7–15.6
15.7–17.0
17.1–18.4
18.5–19.4
19.5–21.3
21.4–24.4
24.5–25.9
26.0–27.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
10.5–12.0
12.1–13.6
13.7–15.6
15.7–17.1
17.2–19.4
19.5–20.9
21.0–22.2
22.3–25.3
25.4–26.9
27.0–30.2
—
30.3–33.3
33.4–35.3
—
35.4–41.5
41.6–45.0
45.1–52.3
52.4–55.7
55.8–60.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
30.0–33.5
33.6–36.4
36.5–39.6
—
39.7–43.6
43.7–46.5
46.6–51.6
51.7–54.4
54.5–58.0
58.1–63.0
63.1–67.7
67.8–72.4
—
—
—
—
—
72.5–80.0
80.1–88.1
88.2–91.5
91.6–96.8
96.9–99.0
99.1–108.0
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
56.9–60.9
61.0–63.9
64.0–67.7
67.8–72.4
72.5–77.7
77.8–85.9
86.0–91.9
92.0–96.7
96.8–105
—
—
106–115
116–130

E6
E7
E8
E9
E11
E12
E13
E14
E16
E17
E18
E19
E23
E24
E26
E27
E28
E29
E31
E32
E33
E34
E36
E37
E38
E39
E41
E42
E44
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56
E57
E60
E61
E62
E65
E66
E67
E69
E70
E71
E72
E73
E73A
E74
E76
E77
E78
E79
E80
E88
E89
E91
E92
E93
E94
E96
E97
E98
E99
E101
E102
E103
E104

8/154

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2.27–2.54
2.55–2.69
2.70–2.88
2.89–3.14
3.15–3.40
3.41–3.81
3.82–4.25
4.26–4.62
4.63–5.09
5.10–5.61
5.62–5.91
5.92–6.15
6.16–6.70
6.71–7.54
7.55–8.29
8.30–8.99
9.00–9.85
9.86–10.4
10.5–12.0
12.1–13.6
13.7–15.6
15.7–17.0
17.1–19.4
19.5–20.9
21.0–22.2
22.3–25.3
25.4–26.9
27.0–30.2
—
30.3–33.3
33.4–36.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

Table 238 for Class 48
Full Load Amps

List Price $

Product Category: NEMA

48DC

48GC

48HA

48JA

Heater
Catalog No

0.30–0.32
0.33–0.35
0.36–0.38
0.39–0.41
0.42–0.44
0.45–0.49
0.50–0.54
0.55–0.58
0.59–0.63
0.64–0.67
0.68–0.73
0.74–0.81
0.82–0.87
0.88–0.94
0.95–1.00
1.01–1.10
1.11–1.26
1.27–1.40
1.41–1.58
1.59–1.74
1.75–1.85
1.86–1.99
2.00–2.11
2.12–2.31
2.32–2.59
2.60–2.75
2.76–2.95
2.96–3.21
3.22–3.48
3.49–3.89
3.90–4.35
4.36–4.73
4.74–5.21
5.22–5.74
5.75–6.05
6.06–6.46
6.47–6.95
6.96–8.09
8.10–9.29
9.30–10.4
—
10.5–10.9
11.0–12.0
12.1–14.5
14.6–16.8
16.9–18.4
18.5–20.9
21.0–22.5
22.6–24.3
24.4–27.2
27.3–29.2
29.3–30.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
16.9–18.4
18.5–20.9
21.0–22.5
22.6–24.7
24.8–27.2
27.3–29.2
29.3–32.0
32.1–34.9
—
35.0–37.8
37.9–41.7
41.8–45.9
46.0–49.0
49.1–54.2
54.3–60.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
27.1–30.0
30.1–33.2
33.3–35.7
35.8–39.4
39.5–43.4
43.5–46.9
—
47.0–51.5
51.6–57.0
57.1–62.8
62.9–69.1
69.2–75.0
75.1–83.3
—
—
—
—
—
—
83.4–86.9
87.0–92.9
93.0–100.0
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
50.0–55.9
56.0–60.9
61.0–65.9
66.0–69.9
70.0–75.9
76.0–81.9
82.0–86.9
87.0–92.9
93.0–97.9
98.0–107.9
108–113.9
114–125.9
126–138.9
139–153.9
154–163.9
164–180.9

E3
E4
E5
E6
E7
E8
E9
E11
E12
E13
E14
E16
E17
E18
E19
E23
E24
E26
E27
E28
E29
E31
E32
E33
E34
E36
E37
E38
E39
E41
E42
E44
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56
E57
E60
E61
E62
E65
E66
E67
E69
E70
E71
E72
E73
E73A
E74
E76
E77
E78
E79
E80
E88
E89
E91
E92
E93
E94
E96
E97
E98
E99
E101
E102
E103
E104
E106
E107

List Price $

Siemens Industry, Inc.
Industrial Controls Catalog

Overload Relay Heater Tables

Full Load Motor Amps, Single Phase, Trip Class 10 – Tables 313, 316
Selection
Table 313 for Class 14, 22 (1-Phase)
Full Load Amps
Size 00, 0, 1

Size 1P

Size 2, 21⁄2

Heater
Catalog No

1.85–2.05
2.06–2.35
2.36–2.64
2.65–2.96
2.97–3.31
3.32–3.51
3.52–3.87
3.88–4.31
4.32–4.79
4.80–5.21
5.22–5.75
5.76–6.11
6.12–6.95
6.96–7.73
7.74–8.47
8.48–9.52
9.53–10.4
10.5–11.1
11.2–12.4
12.5–13.5
13.6–15.1
15.2–16.6
16.7–17.6
17.7–18.8
18.9–21.6
21.7–22.7
22.8–25.3
—
—
—
—
—
—
—
—
—
—
—

1.85–2.05
2.06–2.35
2.36–2.64
2.65–2.96
2.97–3.31
3.32–3.51
3.52–3.87
3.88–4.31
4.32–4.79
4.80–5.21
5.22–5.75
5.76–6.11
6.12–6.95
6.96–7.73
7.74–8.47
8.48–9.52
9.53–10.4
10.5–11.1
11.2–12.4
12.5–13.5
13.6–15.1
15.2–16.6
16.7–17.6
17.7–18.8
18.9–21.6
21.7–22.7
22.8–25.3
25.4–26.6
26.7–30.1
30.2–33.0
33.1–34.1
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
18.7–19.7
19.8–21.3
21.4–22.8
22.9–24.2
24.3–26.5
26.6–29.3
29.4–32.0
32.1–35.6
35.7–37.9
38.0–40.3
40.4–44.3
44.4–49.5
49.6–52.1
52.2–53.7
53.8–60.0

K21
K22
K24
K27
K28
K29
K31
K32
K33
K34
K36
K37
K39
K41
K42
K43
K49
K50
K52
K53
K54
K55
K57
K58
K60
K61
K62
K63
K64
K67
K68
K69
K70
K72
K73
K74
K75
K76

Siemens Industry, Inc.
Industrial Controls Catalog

Table 316 for Class 48
Full Load Amps
List Price $

Product Category: NEMA

48DA

48GA

48HA

48JA

Heater
Catalog No

1.69–1.88
1.89–2.05
2.06–2.21
2.22–2.44
2.45–2.70
2.71–2.92
2.93–3.27
3.28–3.56
3.57–3.83
3.84–4.23
4.24–4.57
4.58–4.97
4.98–5.67
5.68–6.11
6.12–6.91
6.92–7.65
7.66–8.4
8.5–8.9
9.0–10.1
10.2–11.2
11.3–12.3
12.4–13.3
13.4–14.1
14.2–15.0
15.1–16.2
16.3–17.5
17.6–18.6
18.7–19.9
20.0–21.3
21.4–22.8
22.9–25.1
25.2–27.6
27.7–30.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
9.12–9.6
9.7–10.4
10.5–11.4
11.5–12.1
12.2–12.9
13.0–13.7
13.8–14.8
14.9–16.4
16.5–18.2
18.3–19.5
19.6–20.9
21.0–22.8
22.9–24.7
24.8–27.6
27.7–30.5
30.6–33.9
34.0–37.3
37.4–40.2
40.3–41.9
42.0–45.9
46.0–50.9
51.0–52.9
53.0–57.7
57.8–60.0
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
23.2–25.1
25.2–27.3
27.4–30.4
30.5–33.3
33.4–36.5
36.6–39.3
39.4–43.5
43.6–46.6
46.7–51.1
51.2–56.3
56.4–61.1
61.2–64.9
65.0–71.9
72.0–80.7
80.8–92.7
92.8–100.0
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
43.0–46.5
46.6–50.9
51.0–55.9
56.0–59.1
59.2–68.7
—
68.8–80.7
80.8–92.7
92.8–103.9
104.0–113.5
113.6–127.9
128.0–143.9
144.0–163.9
164.0–180.0

K21
K22
K23
K24
K26
K27
K28
K29
K31
K32
K33
K34
K36
K37
K39
K41
K42
K43
K49
K50
K52
K53
K54
K55
K56
K57
K58
K60
K61
K62
K63
K64
K67
K68
K69
K70
K72
K73
K74
K75
K76
K77
K78
K85
K86
K87
K89
K92
K94
K96

List Price $

8/155

Overload Relay Heater Tables

Full Load Motor Amps, 3-Phase, Trip Class 10 – Tables 332, 335
Selection
Table 332 for Class 14, 17, 18, 22, 25, 26, 30, 32, 83, 84, 87 (3-Phase)
Full Load Amps
Size 00, 0, 1

1.52–1.65
1.66–1.79
1.80–1.94
1.95–2.15
2.16–2.37
2.38–2.56
2.57–2.87
2.88–3.13
3.14–3.37
3.38–3.72
3.73–4.00
4.01–4.35
4.36–4.99
5.00–5.38
5.39–5.79
5.80–6.43
6.44–6.83
6.84–7.83
7.84–8.23
8.24–9.59
9.60–9.90
10.0–10.7
10.8–11.6
11.7–12.3
12.4–13.4
13.5–14.2
14.3–15.1
15.2–17.5
17.6–18.7
18.8–20.0
20.1–21.5
21.6–23.9
24.0–25.8
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

8/156

3

Size 1 ⁄4

1.52–1.65
1.66–1.79
1.80–1.94
1.95–2.15
2.16–2.37
2.38–2.56
2.57–2.87
2.88–3.13
3.14–3.37
3.38–3.72
3.73–4.00
4.01–4.35
4.36–4.99
5.00–5.38
5.39–5.79
5.80–6.43
6.44–6.83
6.84–7.83
7.84–8.23
8.24–9.59
9.60–9.90
10.0–10.7
10.8–11.6
11.7–12.3
12.4–13.4
13.5–14.2
14.3–15.1
15.2–17.5
17.6–18.7
18.8–20.0
20.1–21.5
21.6–23.9
24.0–25.8
25.9–29.5
—
29.6–32.7
32.8–36.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

Size 2, 2 ⁄2
1

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
12.1–12.7
12.8–13.5
13.6–14.6
14.7–15.9
16.0–16.9
17.0–18.2
18.3–19.5
19.6–20.9
21.0–23.1
23.2–25.4
25.5–27.9
—
28.0–30.5
30.6–33.5
33.6–37.2
37.3–40.7
40.8–43.0
43.1–47.9
48.0–52.7
52.8–58.3
58.4–60.0
—
—
—
—
—
—
—
—
—
—

Size 3, 3 ⁄2
1

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
36.8–40.0
40.1–42.4
42.5–46.3
46.4–49.6
49.7–52.3
52.4–57.5
57.6–63.9
64.0–67.9
68.0–74.3
74.4–77.9
78.0–83.1
83.2–91.4
91.5–99.9
100.0–108.0
—
—
—
—

Size 4

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
49.7–52.3
52.4–57.5
57.6–63.0
63.1–68.1
68.2–74.3
74.4–79.9
80.0–87.4
87.5–90.0
90.1–100.0
100.1–108.0
108.1–119.0
119.1–130.0
—
—

Table 335 for Class 48

Heater
Catalog No List Price $

K21
K22
K23
K24
K26
K27
K28
K29
K31
K32
K33
K34
K36
K37
K39
K41
K42
K43
K49
K50
K52
K53
K54
K55
K56
K57
K58
K60
K61
K62
K63
K64
K67
K68
K69
K70
K72
K73
K74
K75
K76
K77
K78
K83
K85
K86
K87
K88
K89
K90
K92
K94
K96

Product Category: NEMA

Full Load Amps
48DC

48GC

48HA

48JA

1.56–1.69
1.70–1.84
1.85–1.98
1.99–2.19
2.20–2.43
2.44–2.63
2.64–2.95
2.96–3.21
3.22–3.45
3.46–3.81
3.82–4.10
4.11–4.46
4.47–5.10
5.11–5.49
5.50–6.21
6.22–6.76
6.77–7.62
7.63–8.07
8.08–9.19
9.20–10.0
10.1–11.0
11.1–12.0
12.1–12.7
12.8–13.5
13.6–14.5
14.6–15.7
15.8–16.7
16.8–17.9
18.0–19.2
19.3–20.5
20.6–22.5
22.6–24.8
24.9–27.6
27.7–30.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
18.0–19.2
19.3–20.5
20.6–22.5
22.6–24.8
24.9–27.6
—
27.7–30.1
30.2–33.1
33.2–36.7
36.8–40.1
40.2–45.5
45.6–47.9
48.0–52.7
52.8–55.1
55.2–60.0
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
23.2–25.1
25.2–27.3
27.4–30.4
30.5–33.3
33.4–36.5
36.6–39.3
39.4–43.5
43.6–46.6
46.7–51.1
51.2–56.3
56.4–61.1
61.2–64.9
65.0–71.9
72.0–80.7
80.8–92.7
92.8–100.0
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
43.0–46.5
46.6–50.9
51.0–55.9
56.0–59.1
59.2–68.7
—
68.8–80.7
80.8–92.7
92.8–103.9
104.0–113.5
113.6–127.9
128.0–143.9
144.0–163.9
164.0–180.0

Heater
Catalog No

List Price $

K21
K22
K23
K24
K26
K27
K28
K29
K31
K32
K33
K34
K36
K37
K39

K41
K42
K43
K49
K50
K52
K53
K54
K55
K56
K57
K58
K60
K61
K62
K63
K64
K67
K68
K69
K70
K72
K73
K74
K75
K76
K77
K78
K85
K86
K87
K89
K92
K94
K96

Siemens Industry, Inc.
Industrial Controls Catalog

Replacement Parts

Starters and Contactors – AC Coils
Selection
Ordering Information
䊳

4th character of starter or contactor catalog number indicates model.

AC Coils — For Class 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 40, 43, 83, 84, 87, 88
Volts
Size

Model

60Hz

50Hz

Catalog Number

24
120
110–120/220–240
208
220–240
277
220–240/440–480
440–480
575–600
24
120
110–120/220–240
208
220–240
277
220–240/440–480
440–480
575–600
24
120
120/220–240
208
220–240
277
220–240/440–480
440–480
575–600
23-26
110-127
200-220
220-240
240-277
380-420
440-480
575-600
23-26
110-127
200-220
220-240
240-277
380-420
440-480
575-600
23-26
110-127
200-220
220-240
240-277
380-420
440-480
575-600

24
110
110/190–220
—
190–220
240
190–220/380–440
380–440
550
24
110
110/190–220
—
190–220
240
190–220/380–440
380–440
550
24
110
110/190–220
—
190–220
240
190–220/380–440
380–440
550
23-26
110-127
200-220
220-240
240-277
380-420
440-480
575-600
23-26
110-127
200-220
220-240
240-277
380-420
440-480
575-600
23-26
110-127
200-220
220-240
240-277
380-420
440-480
575-600

75D73070J
75D73070F
75D73070A
75D73070D
75D73070G
75D73070L
75D73070C
75D73070H
75D73070E
75D73251J
75D73251F
75D73251A
75D73251D
75D73251G
75D73251L
75D73251C
75D73251H
75D73251E
75D70131J
75D70131F
75D70131A
75D70131D
75D70131G
75D70131L
75D70131C
75D70131H
75D70131E
3RT1966-5AB31
3RT1966-5AF31
3RT1966-5AM31
3RT1966-5AP31
3RT1966-5AU31
3RT1966-5AV31
3RT1966-5AR31
3RT1966-5AT31
3RT1965-5AB31
3RT1965-5AF31
3RT1965-5AM31
3RT1965-5AP31
3RT1965-5AU31
3RT1965-5AV31
3RT1965-5AR31
3RT1965-5AT31
3RT1975-5AB31
3RT1975-5AF31
3RT1975-5AM31
3RT1975-5AP31
3RT1975-5AU31
3RT1975-5AV31
3RT1975-5AR31
3RT1975-5AT31

00–21⁄2

P
U (ESP200)

3 , 31⁄2

P
U (ESP200)

4

G
U (ESP200)

4, 5

V (Vacuum)

5

P

6

P
V (Vacuum)

7

H

100-250
150-500

100-250
150-500

75ZAF750-70
75ZAF750-71

8

H

100-250

100-250

75ZAF1650-70

List Price $

 Set

of 2 coils. Recommend to change printed circuit
board when changing coils. 49ZP1650 see page 8/158.

Siemens Industry, Inc.
Industrial Controls Catalog

Product Category: NEMA

8/157

Replacement Parts

Starters and Contactors – DC Coils, Late Break Aux Contacts, Rectifiers, Contact Kits
Selection
Ordering Information
䊳
䊳

4th character of starter or contactor catalog number indicates model.
DC Coils for Size 00-4 require Late Break Interlock.

DC Coils — For Class 14, 17, 18, 22, 25, 26, 30, 32, 40, 43
Size

Model

00–21⁄2

P
U (ESP200)

3, 31⁄2

P
U (ESP200)

4

G
U (ESP200)

4, 5

V (Vacuum)

Volts DC

Catalog Number

12
24
32
48
125
250
12
24
32
48
125
250
48
125
250
23-26
42-48
110-127
240-277

75D73070R
75D73070S
75D73070T
75D73070U
75D73070V
75D73070W
75D73251R
75D73251S
75D73251T
75D73251U
75D73251V
75D73251W
75D70131U
75D70131V
75D70131W
3RT1966-5AB31
3RT1966-5AD31
3RT1966-5AF31
3RT1966-5AU31

List Price $

Note: For sizes 7 & 8 contactors the AC coils are used for DC see page 16-155.

Board for Size 8 Contactor

Late Break Auxiliary Contacts
Control Size

Model

Catalog Number List Price $

Control Size

Model

Catalog Number List Price

00–4

P, G, S, T

49AB01LB

8

H

49ZP1650

Contact Kits – Single Pole Stationary and Movable Contacts, Contact Spring 
Description

Size

Number of Poles in Kit
3

Class 14, 17, 18, 22, 25,
26, 30, 32, 36, 37, 40, 43,
83, 84, 87, 88
14, 40

Internal Aux Contact (00-1- ⁄4)
00
0
1
13⁄4–1P
2
21⁄2
3
31⁄2
4
4 (Vacuum)
5
5 (Vacuum)
6
6 (Vacuum)
7
8

1
1
1
1
1
3 (Bottles)
3
3 (Bottles)
3
3 (Bottles)
3
3

Model
(4th position in part number)

P, U
P, U
P, U
P, U
P, U
P, U
P, U
P, U
P, U
G, T
V, C
P
V, C
P
V, C
H
H

Catalog Number

List Price $

75AF14
75BF14
75CF14
75DF14
75EF14
75FP14
75GP14
75HF14
75IF14
75JG14
3RT1964-6V
3RT1966-6A
3RT1966-6V
3RT1976-6A
3RT1976-6V
49ZL750
49ZL1650

Armature and Magnet Kits
Size

Catalog Number

00–21⁄2

49AMSA2

3–31⁄2

49AMSA3

4

49AMSA4

List Price $

 On

3-phase controls, all 3-poles should be replaced 3 kits required.

8/158

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Replacement Parts

Starters and Contactors – Coil VA Ratings and Overload Relays
Selection
Coil VA Ratings
Device Type

NEMA Starter

Lighting Contactor
Mechanically Held (CLM)

Lighting Contactor
Electrically Held Held (LE)

Contactor Size

Amps

00 thru 2 1/2
3 thru 3 1/2
4
5
6
7
8
4,5,6 (Vacuum)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
20
30
60
60
100 - 200
100 - 200
300 - 400
20
20
20
20
20
20
20
20
20
20
20
20
20
20
30
30
30
30
30
30
30
60
60
60
60
60
60
60
100
100
100
100
100
100
100
200
300
400

Volts

—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
24
120
208
240
277
480
600
24
120
208
240
277
480
600
24
120
208
240
277
480
600
24
120
208
240
277
480
600
24
120
208
240
277
480
600
All Voltages
Electrically
Held

Number of Poles

Total Inrush VA

Total Sealed VA

—
—
—
—
—
—
—
—
2-12
2-5
2-3
4-5
2-3
4-5
3
3
3
3
3
3
3
3
12
12
12
12
12
12
12
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

218
310
510
590
830
850
1900
630
6
40
40
40
200
130
550
49.6
51.3
75.79
86.78
79.1
83.7
84.1
73.31
75.1
73.97
89.15
78.55
84
81.9
49.67
51.94
76.57
64.44
77.85
83.6
82.1
74.94
75.77
78.73
89.92
84.89
87.6
85.4
182.28
191.42
187.78
215.32
175.92
198.2
171.1
300
590
830

25
26
51
6.7
9.2
12
48
7.4
625
410
410
600
900
1300
1600
6.9
6.57
11.94
14.25
11.97
12.9
13.2
12.66
13.1
13.25
14.85
12.77
12.9
13.4
7.08
6.48
11.78
8.99
14.2
13.1
13.4
13.16
13.59
12.05
14.42
12.93
12.7
13.8
32.85
32.26
31.15
35.63
30.62
34.8
29.6
5.8
6.7
9.2

Overload Relays – For Class 14, 17, 18, 22, 25, 26, 30, 32, 83, 84, 87
Size

Half
Size

Ambient Comp Bimetal
Model

00–1

—

P

1P
—

—
13⁄4

P
P

2

—

P

—

21⁄2

P

3
—
4

—
31⁄2
—

P
P
G

Number Poles

Catalog Number (1) NC

1
3
1
3
1
3
1
3
3
3
3

48DC18AA3
48DC38AA3
48EC18AA3
48EC38AA3
48GC18AA3
48GC38AA3
48GC18AA3
48GC38AA3
48HC38AA3
48HC38AA3
48JC38AA3

List Price $

Catalog Number (1) NO/NC

List Price $

48DC39AA3
48EC39AA3
48GC39AA3
48GC39AA3

For Starter and Contactor replacement parts not found in this section, please refer to Field Modification kits found starting on page 8/81.
 For

replacement Solid State overload relays, please see the Overload Relay section
found starting on page 8/49.

Siemens Industry, Inc.
Industrial Controls Catalog

 Includes

Product Category: NEMA

overload mounting plate to be coupled to contactor mounting plate.

8/159

Replacement Parts

Lighting and Heating Contactors, Type LE, CLM, CMF, CMN
Selection
AC Coils – 20-400 Amps
Type

LE
3 RT 1 9 5 5 - 5 A F 3 1

Contactor
Size

Catalog Number
24VAC
120VAC

208VAC

240VAC

277VAC

480VAC

600VAC

20, 30, 60 Amp 75D70646J

75D70646F

75D70646D

75D70646G

75D70646L

75D70646H

75D70646E

100 Amp

75D54772J

75D54772F

75D54772D

75D54772G

75D54772L

75D54772H

75D54772E

200 Amp

3RT1955-5AB31 3RT1955-5AF31

3RT1955-5AM31 3RT1955-5AP31

3RT1955-5AU31

3RT1955-5AR31 3RT1955-5AT31

300 Amp

3RT1965-5AB31 3RT1965-5AF31

3RT1965-5AM31 3RT1965-5AP31

3RT1965-5AU31

3RT1965-5AR31 3RT1965-5AT31

400 Amp

3RT1975-5AB31 3RT1975-5AF31

3RT1975-5AM31 3RT1975-5AP31

3RT1975-5AU31

3RT1975-5AR31 3RT1975-5AT31

List
Price $

Main Contacts (Includes 3 Moving and 6 Fixed Contacts)
Type

LE
3 RT 1 9 6 5 - 6 A

Contactor Size

Catalog Number

20–100 Amp

Not Replaceable

200 Amp

3RT1956-6A

300 Amp

3RT1965-6A

400 Amp

3RT1975-6A

List Price $

—

Lighting Contact Assembly - 20 Amp (Power Poles)
Type

Catalog
Number

Contactor Size

(Verify catalog number on
side of contact assembly)

List Price $

49LN02A, 2 NC Contacts Non-Stackable
LE

49LN20A, 2 NO Contacts Non-Stackable

20 Amp

49LS20A, 2 NO Contacts Stackable
49LS10A, 1 NO Contact Stackable

AC Coils 20 Amps

CLM4097341

Type

Contactor
Size

Number
of Poles

120V, 60Hz
110V, 50Hz

CLM

20 Amp

2–12

CLM4097341

List
Price $

240V, 60Hz
208V, 50Hz

List
Price $

CLM4097342

277V
50/60Hz

List
Price $

480V, 60Hz
440V, 50Hz

CLM4097343

List
Price $

CLM4097344

AC Coils 30–400 Amps

CLMC4C120

CLMGU3C120

Type

Contactor
Size

CLM†C

30 Amp

CLM†D

60 Amp

CLM†E

100, 200
Amp

CLM†G
Latching Coil
Unlatch Coil
CLM†H
Latching Coil
Unlatch Coil

Catalog Number

Number
of Poles

24V AC

120V AC

208V AC

220/240V AC

277V AC

480V AC

600V AC

2–3-Pole
4-Pole
5-Pole
2–3-Pole
4-Pole
5-Pole
2–3-Pole
4-Pole
5-Pole

CLMC4C024
CLMC4C024
CLMC5C024
CLMD3C024
CLMD5C024
CLMD5C024
CLME3C024
CLME5C024
CLME5C024

CLMC4C120
CLMC4C120
CLMC5C120
CLMD3C120
CLMD5C120
CLMD5C120
CLME3C120
CLME5C120
CLME5C120

CLMC4C208
CLMC4C208
CLMC5C208
CLMD3C208
CLMD5C208
CLMD5C208
CLME3C208
CLME5C208
CLME5C208

CLMC4C240
CLMC4C240
CLMC5C240
CLMD3C240
CLMD5C240
CLMD5C240
CLME3C240
CLME5C240
CLME5C240

CLMC4C277
CLMC4C277
CLMC5C277
CLMD3C277
CLMD5C277
CLMD5C277
CLME3C277
CLME5C277
CLME5C277

CLMC4C480
CLMC4C480
CLMC5C480
CLMD3C480
CLMD5C480
CLMD5C480
CLME3C480
CLME5C480
CLME5C480

CLMC4C600
CLMC4C600
CLMC5C600
CLMD3C600
CLMD5C600
CLMD5C600
CLME3C600
CLME5C600
CLME5C600

300 Amp

2–3-Pole
2–3-Pole

—
—

CLMGL3C120 CLMGL3C208 CLMGL3C240 CLMGL3C277 CLMGL3C480 CLMGL3C600
CLMGU3C120 CLMGU3C208 CLMGU3C240 CLMGU3C277 CLMGU3C480 CLMGU3C600

400 Amp

2–3-Pole
2–3-Pole

—
—

CLMHL3C120 CLMHL3C208 CLMHL3C240 CLMHL3C277 CLMHL3C480 CLMHL3C600
CLMHU3C120 CLMHU3C208 CLMHU3C240 CLMHU3C277 CLMHU3C480 CLMHU3C600

List
Price $

.

Control Module Rectifier
Type

Device

Contactor Size

Number of Poles

Catalog Number

CLM

CLM†C to
CLM†F

30–200 Amps

All

CLMKCMR

 Product Category: IEC.
 Coil kits for 20 amp CLM

contactors include the coil
clearing auxiliary contact.

8/160

List Price $

 For

30–200 amp CLM contactors, in the event that
either the coil or the control module fails, it is
recommended that both be replaced.

Product Category: NEMA

Siemens Industry, Inc.
Industrial Controls Catalog

Replacement Parts

Lighting Contactors, CLM, CMB, CMF, CMN & Combination Replacement Handles
Selection
Ordering Information
䊳
䊳

For CLM: 5th character of contactor catalog number indicates Frame Size.
For CMB, CMF, CMN: 4th character of contactor catalog number indicates Frame Size.

Main Contacts 20 Amp Lighting Contactors
Type

Contactor
Size

Number of
Poles

Location

Catalog
Number

CLM

20 Amp

2
3
4
6

Top or Bottom
Top
Top or Bottom
Top or Bottom

CLM4097331
CLM4097332
CLM4097333
CLM4097334

CLM4097334

List
Price $

Main Contacts 30–400 Amp Lighting Contactors
Type

CLM

Frame
Size

Contactor
Size

Number of
Poles

Catalog
Number

C

30 Amp

2
3
4
5

CLMCCK02
CLMCCK03
CLMCCK04
CLMCCK05

D

60 Amp

2
3
4
5

CLMDCK02
CLMDCK03
CLMDCK04
CLMDCK05

E

100 Amp

2
3
4
5

CLMECK02
CLMECK03
CLMECK04
CLMECK05

F

200 Amp

2
3
4
5

CLMFCK02
CLMFCK03
CLMFCK04
CLMFCK05

G

300 Amp

2
3

CLMGCK02
CLMGCK03

H

400 Amp

2
3

CLMHCK02
CLMHCK03

List
Price $

Auxiliary Contact Blocks 20 Amp Lighting Contactors
Type

Contactor
Size

CLM

20 Amp

Contacts

Catalog
Number

1 Form C NO, NC Contact
2 Form C NO, NC Contacts

CLM4097291
CLM4097292

List
Price $

Auxiliary Contact Blocks 30–400 Amp Lighting Contactors
Type

Frame
Size

Contactor
Size

C to F

30–200 Amps

G to H

300–400 Amps

CLM

CLMFCAK11

Contact
Configuration

Catalog
Number

List
Price $

1 NO and 1 NC
2 NC
2 NO
1 Coil Clearing
NO and NC

CLMFCAK11
CLMFCAK02
CLMFCAK20
CLMFCCK11

1 NO and 1 NC
2 NC
2 NO
1 Coil Clearing
NO and NC

CLMHCAK11
CLMHCAK02
CLMHCAK20
CLMHCCK11

Combination Starters Class 17, 18, 25, 26 & 32
Replacement Handle Assemblies
NEMA 1, 4, 12 Enclosure Class 17, 25, 32
Disc
Standard
List
Extra
Size
Width
Price $
Wide

30-100A
200A
 Maximum
 Maximum

75D68257103
75D68257105

75D68257103
—

List
Price $

—

NEMA 1, 4, 12 Enclosure Class 18, 26, 32
Circuit
Standard
List
Extra
Breaker Width
Price $
Wide

3-100A
125A
150A

75D68257080
75D68257096
75D68257089

75D68257080
—
—

List
Price $

—
—

1 block per contactor.
2 blocks per contactor.

Siemens Industry, Inc.
Industrial Controls Catalog

Product Category: NEMA

8/161

Replacement Parts

Notes

8/162

Siemens Industry, Inc.
Industrial Controls Catalog



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c320 44.290368, Sun Jun 10 2007 17:23:03
Modify Date                     : 2009:08:27 10:31:24-05:00
Create Date                     : 2009:08:27 10:30:50-05:00
Metadata Date                   : 2009:08:27 10:31:24-05:00
Document ID                     : uuid:265503c8-f31f-4244-8cd4-ff20d6fd843e
Instance ID                     : uuid:7f407a24-2e52-4431-9a1d-789c007eb5b6
Format                          : application/pdf
Producer                        : Creo Normalizer JTP
Trapped                         : False
Page Count                      : 162
EXIF Metadata provided by EXIF.tools

Navigation menu