111409 Catalog
2014-09-05
: Pdf 111409-Catalog 111409-Catalog 783087 Batch7 unilog
Open the PDF directly: View PDF
.
Page Count: 162
| Download | |
| Open PDF In Browser | View PDF |
Control Products
Contents
Pages
What’s New . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/3
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/4
NEMA & General Purpose Control
Manual Control
Fractional HP Starters, Class SMF . . . . . . . . . . . . . . . . . . . . . . . . . . .8/5 – 8/6
Switches, Class MMS and MRS . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/7 – 8/8
Starters and Switches, Class 11 - 3RV . . . . . . . . . . . . . . . . . . . . . . .8/9 – 8/10
NEMA Control
Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/11
Non-Combination Starters Features and Benefits . . . . . . . . . . . . .8/12 – 8/13
Non-Reversing Starters, Class 14 . . . . . . . . . . . . . . . . . . . . . . . . . .8/14 – 8/16
Combination Starters Features and Benefits . . . . . . . . . . . . . . . . . . . . . .8/17
Combination Starters, Class 17 and 18 . . . . . . . . . . . . . . . . . . . . .8/18 – 8/26
Reversing Starters, Class 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/27 – 8/28
Combination Reversing Starters, Class 25 and 26 . . . . . . . . . . . . .8/29 – 8/30
Two Speed Starters Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . .8/31
Two Speed Starters, Class 30 . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/32 – 8/35
Combination Two Speed Starters, Class 32 . . . . . . . . . . . . . . . . . .8/36 – 8/43
Non-Reversing Contactors, Class 40 . . . . . . . . . . . . . . . . . . . . . . .8/44 – 8/45
Vacuum Contactors, Class 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/45
Reversing Contactors, Class 43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/46
Overload Relays, Class 48, 958 and 3RB20 . . . . . . . . . . . . . . . . . .8/47 – 8/51
Duplex Controllers
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/52
Non Combination, Class 83 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/53
Combination, Class 84 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/54 – 8/55
Pump Control Panels
Irrigation, Class 81 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/56
Class 87 and 88 Features and Benefits . . . . . . . . . . . . . . . . . . . . .8/57 – 8/58
Full-Voltage Type, Class 87 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/59 – 8/60
Vacuum Starter Type, Class 87 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/61
Reduced-Voltage Type, Class 88 . . . . . . . . . . . . . . . . . . . . . . . . . .8/62 – 8/63
Reduced Voltage Control
Reduced Voltage Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . .8/64
Auto Transformer Starters, Class 36 and 37 . . . . . . . . . . . . . . . . . . . . . . .8/65
Part Winding Starters, Class 36 and 37 . . . . . . . . . . . . . . . . . . . . . . . . . . .8/66
Wye Delta Open Transition, Class 36 and 37 . . . . . . . . . . . . . . . . . . . . . .8/67
Wye Delta Closed Transition, Class 36 and 37 . . . . . . . . . . . . . . . . . . . . .8/68
Lighting Control
Electrically Held Contactors, Class LE . . . . . . . . . . . . . . . . . . . . . .8/69 – 8/71
Mechanically Held Contactors, Class CLM . . . . . . . . . . . . . . . . . .8/72 – 8/74
Control Power Transformers
Domestic and International (UL, CSA and CE),
Class MT and MTG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/75 – 8/79
Siemens Industry, Inc.
Industrial Controls Catalog
8/1
Control Products
Contents
Pages
Modifications and Drawings
Field Modification Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/80 – 8/90
Enclosure Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/91 – 8/94
Factory Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/95 – 8/99
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/100 – 8/129
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/130 – 8/149
Heater Tables and Replacement Parts
Overload Relay Heater Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/150 – 8/156
NEMA Coils and Contact Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/157 – 8/158
Coil VA Ratings and Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/159
Lighting Contactor Parts and Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8/160 – 8/161
8/2
Siemens Industry, Inc.
Industrial Controls Catalog
Control Products
What’s new
Irrigation Pump Panel
with Solid State
Overload, Class 81
Siemens introduces its
new Class 81 Irrigation
Pump Panel. This newest
addition to the already
extensive line of Siemens
pump panels was designed
specifically for the agricultural market. It is well suited for irrigation and similar
pumping applications and is
built to withstand the
harsh elements of the
outdoors. Refer to page
8/56 for more details and
selection.
ESP200™ Solid State Overload Relay
Building and improving on past successes, self-powered
ESP200 overload relays are a revolution for both industrial and
construction applications.
Ideal for oil pumping, agriculture, OEM operations and any
other industrial applications where motor life is monitored and
single-phase protection is important, NEMA starters equipped
with ESP200 are both versatile and rugged.
Refer to page 8/47 for more details and information.
Siemens Industry, Inc.
Industrial Controls Catalog
8/3
Control Products
NEMA & General Purpose Controls
Product Overview
Class SMF
Fractional Horsepower
Manual Starters
Page 8/5
Class MMS & MRS
Fractional Horsepower
Manual Switches
Page 8/7
Class 11
Manual Starters and
Switches
Page 8/9
Class 22
NEMA Reversing
Starters
Page 8/27
Class 25, 26
NEMA Combination
Reversing Starters
Page 8/29
Class 30
NEMA Multi-Speed
Starters
Page 8/32
Class 40
NEMA Contactors
and Vacuum Contactors
Page 8/44
Class 43
NEMA Reversing
Contactors
Page 8/46
Class 48, 958, 3RB20
Overload Relays
Page 8/47
Class MT, MTG
Control Power
Transformers
Page 8/75
Modifications and
Drawings
Page 8/80
Heater Tables and
Replacement Parts
Page 8/150
8/4
Class 14
NEMA Starters
Page 8/14
Class 32
NEMA Combination
Multi-Speed Starters
Page 8/36
Class 81, 83, 84,
87, 88
Pump Controls
Page 8/53
Class 17, 18
NEMA Combination
Starters
Page 8/18
Class 36, 37
Reduced Voltage
Electromechanical
Starters
Page 8/64
Class LE, CLM
Lighting Contactors
Page 8/69
Siemens Industry, Inc.
Industrial Controls Catalog
Manual Control
Fractional HP Starters, Class SMF
General
Class SMF
Class SMF fractional horsepower
starters provide overload protection as
well as manual on-off control for small
horsepower motors in a variety of
industrial and commercial applications.
Available in one or two pole versions,
these devices are suitable for use with
AC single phase motors up to 1 HP.
Two pole starters can also be used
with DC motors up to 3⁄4 HP. Typical
applications include fans, conveyors,
pumps, and small machine tools.
Continuous Current Rating
16 amperes.
Overload Trip Assembly
Motor protection is provided by a Class
SMFH heater element which must be
installed before the starter will operate.
Two Speed Starters
Two speed manual starters are
designed for control of small single
phase AC motors having separate
windings for high and low speed
operation. Two toggle operated starters
are used, with overload protection
included for each motor winding.
Surface mounting devices, and those
with a gray flush plate, utilize a
mechanical interlock which allows
direct control of the motor by means
of the toggle operators.
Enclosures
Class SMF, NEMA Type 1 surface
mounting enclosures are sheet steel
with a thermo-plastic wrap-around cover
for convenience in wiring. The NEMA
Type 1 enclosure is also available in an
oversized version which allows more
wiring space. A zinc alloy die casting is
used for NEMA Type 4 enclosures.
Pilot Lights
Red or green neon pilot light units
are available for flush mounting plates,
NEMA Type 1 enclosures, and NEMA
Type 4 enclosures. Pilot lights may be
either factory or field installed. (For
starters that contain a pilot light, a Red
light is standard. For a Green pilot light
add ”G” to the end of the catalog
number.)
Terminals
Binding head screw type terminals are
suitable for #10 or smaller copper wire,
and are accessible from the front. All
terminals are clearly marked.
Mounting
Open types without a pilot light fit
standard single gang switch boxes, and
can be used with any cover plate having
a standard toggle cutout. Single-unit
flush mounting types, including those
with pilot lights, are suitable for wall
mounting in a standard switch box or
for machine cavity mounting without
a box.
Operation
Available with toggle handle or with
removable key type operator to
discourage unauthorized operation.
Siemens Industry, Inc.
Industrial Controls Catalog
Class SMF Starter in a NEMA Type 1
Enclosure with Pilot Light
Emergency Off Actuator
A toggle operator extender is available
for Class SMF, NEMA Type 1 surface
mounted units. The extender has a red
vinyl button that provides a fast and
easy method for locating and switching
the device‘s toggle operator into the
OFF position. The Emergency Off
Actuator is available in kit form only
for field installation.
Handle Guard/Lock-Off
An optional handle guard on Class
SMF, NEMA Type 1 enclosed starters
prevents accidental operation of the
toggle operator and also allows the
toggle operator to be padlocked in
either the “ON” or “OFF” position.
This handle guard can be factory
installed on NEMA Type 1 enclosed
starters and is also available in kit form
for field installation on NEMA Type 1
surface and flush mounting enclosures.
Standard NEMA Type 4 metallic
enclosures include provisions for
padlocking the device in the
OFF position.
8/5
Manual Control
Fractional HP Starters with Melting ALloy Overload, Class SMF
Selection
Ordering Information
Horsepower Ratings
Maximum Horsepower
Heater Elements see page 8/150.
䊳 Field Modification Kits see page 8/80.
䊳 Dimensions see page 8/100.
䊳 Wiring Diagrams see page 8/130.
䊳
AC Single Phase
DC
1-Pole
2-Pole
2-Pole
115–230
1
1
34
277
1
1
—
Volts
Class SMF Starter in a NEMA Type 1
Enclosure with Pilot Light
⁄
Starter—Class SMF, Single Phase
General Purpose Flush Mounting
Open Starter with Flush Plate
(No Enclosure Provided)
Standard
Stainless
Steel
Flush Plate
Gray
Flush
Plate
NEMA Type 1 General Purpose
Enclosure, Surface Mounting
Jumbo
Stainless
Steel
Flush Plate
Type
Open Type
of
No. of
Catalog List Catalog List Catalog List Catalog
Operator Poles Starter Features Number Price $ Number Price $ Number Price $ Number
Standard
Red Pilot Light
Standard
Red Pilot Light
Standard
Red Pilot Light
Standard
Red Pilot Light
1
Toggle
2
1
Key
2
SMFF01
SMFF01P
SMFF02
SMFF02P
SMFF03
SMFF03P
SMFF04
SMFF04P
SMFFF1
SMFFF1P
SMFFF2
SMFFF2P
SMFFF3
SMFFF3P
SMFFF4
SMFFF4P
SMFFS1
SMFFS1P
SMFFS2
SMFFS2P
SMFFS3
SMFFS3P
SMFFS4
SMFFS4P
Standard
List
Catalog
Price $ Number
—
SMFFSJ1P
—
SMFFSJ2P
—
SMFFSJ3P
—
SMFFSJ4P
—
—
—
—
NEMA Type
3R, 4 & 12
NEMA
Type 4
Watertight,
Dust-tight
Metallic
Enclosure
with Clear Cover
Watertight,
Dust-tight
Metallic
Enclosure
NEMA Type
3R, 7 & 9
Div 1 and Div 2
Class I Groups
B, C, D &
Class II Groups
E, F, G
Enclosures
Oversized
List Catalog
Price $ Number
List
Catalog
Price $ Number
List
Catalog
Price $ Number
List
Catalog
Price $ Number
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
List
Price $
SMFFG1
SMFFG1P
SMFFG2
SMFFG2P
SMFFG3
SMFFG3P
SMFFG4
SMFFG4P
SMFFGJ1
SMFFGJ1P
SMFFGJ2
SMFFGJ2P
SMFFGJ3
SMFFGJ3P
SMFFGJ4
SMFFGJ4P
SMFFWN1
SMFFWN1P
SMFFWN2
SMFFWN2P
SMFFWN3
SMFFWN3P
SMFFWN4
SMFFWN4P
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
SMFFG5
SMFFG5P
—
—
SMFFGJ5
SMFFGJ5P
—
—
—
—
—
—
—
—
SMFFW1
SMFFW1P
SMFFW1H
SMFFR1
—
—
SMFFR1H
—
—
—
—
—
SMFFW1PH
—
Starter With Handle Guard/Lock-Off—Class SMF, Single Phase
Standard
Red Pilot Light
(2) 3⁄4" NPT Outlets
(2) 3⁄4" NPT Outlets
and Red Pilot Light
Standard
Red Pilot Light
(2) 3⁄4" NPT Outlets
(2) 3⁄4" NPT Outlets
and Red Pilot Light
1
Toggle
2
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
SMFFG6
SMFFG6P
—
—
SMFFGJ6
SMFFGJ6P
—
—
—
—
—
One Starter in Duplex Enclosure—Class SMF, Single Phase
—
—
—
—
—
—
—
—
—
—
SMFFW2
SMFFW2P
SMFFW2H
SMFFR2
—
—
SMFFR2H
—
—
—
SMFFW2PH
—
—
General Purpose Flush Mounting
Open Starter with Flush Plate - (No Enclosure Provided)
Type of
Operator
Number
of Poles
Toggle
2
Key
2
Starter Features
Standard
Red Pilot Light
Red Pilot Light
Gray Flush Plate
For Wall or Cavity
Mounting
Stainless Steel Flush
Plate for Wall or Cavity
Mounting
NEMA Type 1 General
Purpose Enclosure
Surface Mounting
Catalog Number
—
—
—
Catalog Number
—
—
—
List Price $
—
—
—
Catalog Number List Price $
SMFFG02
SMFFG02P
SMFFG04P
—
SMFFS22P
SMFFS44P
—
SMFFG222
SMFFG222P
SMFFG44P
List Price $
—
—
—
Replacement
Starters
Catalog Number
—
—
—
List Price $
—
—
—
Two Starters In Duplex Enclosure—Class SMF, Single Phase
Toggle
2 Per Starter
Key
2 Per Starter
Standard
Red Pilot Light on Each Starter
Red Pilot Light on Each Starter
SMFFF222
SMFFF222P
SMFFF44P
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
SMFF01T
SMFF01PT
Starter And “Auto-Off-Hand” SPDT Selector Switch (AC Only)—Class SMF, Single Phase
1
Toggle
2
Key
2
Standard
Red Pilot Light
Standard
Red Pilot Light
Red Pilot Light
SMFFF71
SMFFF71P
SMFFF72
SMFFF72P
SMFFF74P
—
SMFFS71P
—
SMFFS72P
SMFFS74P
—
—
SMFFG71
SMFFG71P
SMFFG72
SMFFG72P
SMFFG74P
—
—
—
—
SMFFG11
SMFFG11P
—
—
SMFFG22
SMFFG22P
Two Speed Starters (AC Only)—Class SMF, Single Phase
1
Toggle
2
Mechanical Interlock
Mechanical Interlock and (2) Red Pilot Lights
Mechanical Interlock, HIGH-OFF-LOW
Selector Switch and (2) Red Pilot Lights
Mechanical Interlock
Mechanical Interlock and (2) Red Pilot Lights
Mechanical Interlock, HIGH-OFF-LOW
Selector Switch and (2) Red Pilot Lights
One heater element required.
Furnished with (1) 3⁄4" NPT Outlet
in bottom
SMFFF11
SMFFF11P
—
—
SMFFF22
SMFFF22P
—
SMFFS101P
—
—
—
SMFFS202P
Two heater elements required.
Order Open Type starter plus separate
—
—
SMFF01PT
SMFF02T
SMFF02PT
—
SMFF02PT
For
handle guard kit.
(reversible for top feed).
8/6
—
Product Category: NEMA
starters that contain a pilot light, a Red light is
standard. For a Green pilot light add ”G” to the end of
the catalog number.
Siemens Industry, Inc.
Industrial Controls Catalog
Manual Control
Fractional HP Switches, Class MMS, MRS
General
Class MMS, MRS
Enclosures
Class MMS and MRS motor starting
switches provide manual “ON-OFF”
control of single or three phase AC
motors where overload protection is
not required or is provided separately.
Compact construction and a 600 volt
rating make these switches suitable
for a wide range of industrial and
commercial uses. Typical applications
include small machine tools, pumps,
fans, conveyors and many other types
of electrical machinery. They can also
be used on non-motor loads such as
resistance heating applications.
Class MMS, MRS, NEMA Type 1
surface mounting enclosures are sheet
steel with a thermo-plastic wrap-around
cover for convenience in wiring.
The NEMA Type 1 enclosure is also
available in an oversized version which
allows more wiring space. A zinc alloy
die casting is used for NEMA Type 4
enclosures.
Continuous Current Rating
MMS & MRS: 30 amperes at 250
volts max, 26.4 amperes at 277 volts,
20 amperes at 600 volts max, 30
amperes resistive at 600 volts max.
Two Speed—Class MRS
Two speed manual switches may be
used with separate winding three phase
or single phase AC motors where
overload protection is not required or is
provided separately. Two switches are
employed to give “ON-OFF” control in
each speed.
Reversing—Class MRS
Reversing manual switches provide
a compact means of starting, stopping
and reversing AC motors where
overload protection is not required or
is provided separately. They are suitable
for use with three phase squirrel cage
motors and for single phase motors
which can be reversed by reconnecting
motor leads. Two switches are used,
one to connect the motor forward
rotation and one for reverse.
Siemens Industry, Inc.
Industrial Controls Catalog
Pilot Lights
Red or green neon pilot light units
are available for flush mounting plates,
NEMA Type 1 enclosures, and NEMA
Type 4 enclosures. Pilot lights may be
either factory or field installed. (For
switches that contain a pilot light, a Red
light is standard. For a Green pilot light
add ”G” to the end of the catalog
number.)
Terminals
Binding head screw type terminals are
suitable for #10 or smaller copper wire,
and are accessible from the front. All
terminals are clearly marked.
Mounting
Open types without a pilot light fit
standard single gang switch boxes, and
can be used with any cover plate having
a standard toggle cutout. Single-unit
flush mounting types, including those
with pilot lights, are suitable for wall
mounting in a standard switch box or
for machine cavity mounting without
a box.
Operation
Available with toggle handle or with
removable key type operator to
discourage unauthorized operation.
Class MMS Switch in a
NEMA Type 1 Enclosure
Emergency Off Actuator
A toggle operator extender is available
for Class MMS, MRS, NEMA Type 1
surface mounted units. The extender
has a red vinyl button that provides a
fast and easy method for locating and
switching the device‘s toggle operator
into the OFF position. The Emergency
Off Actuator is available in kit form
only for field installation.
Handle Guard/Lock-Off
An optional handle guard on Class
MMS, MRS, NEMA Type 1 enclosed
switches prevents accidental operation
of the toggle operator and also allows
the toggle operator to be padlocked in
either the “ON” or “OFF” position. This
handle guard is available in kit form for
field installation on NEMA Type 1
surface and flush mounting enclosures.
Standard NEMA Type 4 metallic
enclosures include provisions for
padlocking the device in the
OFF position.
8/7
Manual Control
Switches, Class MMS, MRS
Selection
Ordering Information
Horsepower Ratings
䊳
Heater Elements not Required.
Field Modification Kits see
page 8/80.
Dimensions see page 8/100.
䊳
Wiring Diagrams see page 8/130.
䊳
䊳
Device
Class MMS
Class MRS
Reversing
Class MMS
Two Speed
Class MMS Switch in a
NEMA Type 1 Enclosure
Maximum HP
No of
Poles
Motor Type
AC
2
3
2
3
2
3
3
Single Phase
3-Phase
Single Phase
3-Phase
Single Phase
3-Phase, Constant or Variable Torque
3-Phase, Constant Horsepower
115V
2
2
2
2
2
2
2
DC Ratings
230V
450–575V 90V
115V 230V
2
71/2
2
71/2
2
71/2
71/2
3
10
3
10
3
10
10
2
2
2
2
2
2
2
1
1
1
1
1
1
1
11/2
11/2
11/2
11/2
11/2
11/2
11/2
Switch—Class MMS, Single Phase and 3-Phase
General Purpose Flush Mounting
Open Switch with Flush Plate
(No Enclosure Provided)
Standard
Jumbo
Gray
Stainless
Stainless
Flush
Steel
Steel
Plate
Flush Plate
Flush Plate
Type
No
Open Type
of
of
Switch
Catalog
List Catalog
Operator Poles Features Number
Price $ Number
2
Toggle
3
2
Key
List Catalog
Price $ Number
Standard
MMSK01
Red Pilot Light
MMSK01A
115V AC
MMSKF1
MMSKS1
—
MMSKF1A
MMSKS1A
MMSKSJ1A
Red Pilot Light
MMSK01B
230V AC
MMSKF1B
MMSKS1B
MMSKSJ1B
Standard
MMSKF2
MMSKS2
—
Red Pilot Light
208-240V AC MMSK02B
MMSKF2B
MMSKS2B
MMSKSJ2B
Red Pilot Light
440-600V AC MMSK02C
MMSKF2C
MMSKS2C
MMSKSJ2C
Standard
MMSKF3
MMSKS3
—
Red Pilot Light
MMSK03A
115V AC
MMSKF3A
MMSKS3A
MMSKSJ3A
Red Pilot Light
MMSK03B
230V AC
MMSKF3B
MMSKS3B
MMSKSJ3B
MMSKF4
MMSKS4
—
MMSKF4B
MMSKS4B
MMSKF4C
MMSKS4C
MMSK02
MMSK03
Standard
MMSK04
Red Pilot Light
MMSK04B
208–240V AC
3
List Catalog
Price $ Number
Red Pilot Light MMSK04C
440–600V AC
NEMA Type 1 General Purpose
Enclosure Surface Mounting
NEMA Type
3R, 4 & 12
NEMA
Type 4
NEMA
Type 7 & 9
Watertight,
Dust-tight
Watertight,
Dust-tight
Metallic Enclosurer Metallic
with Clear Cover
Standard
List Catalog
Price $ Number
—
Class I Groups
B, C & D &
Class II Groups
E, F, G
Enclosures
Enclosure
Oversized
List Catalog
Price $ Number
List Catalog
Price $ Number
List
Catalog
Price $ Number
List
Catalog
Price $ Number
List
Price $
MMSKG1
MMSKGJ1
MMSKWN1
MMSKW1
MMSKR1
MMSKG1A
MMSKGJ1A
MMSKWN1A
MMSKW1A
—
—
MMSKG1B
MMSKGJ1B
MMSKWN1B
MMSKW1B
—
—
MMSKG2
MMSKGJ2
MMSKWN2
MMSKW2
MMSKR2
MMSKG2B
MMSKGJ2B
MMSKWN2B
MMSKW2B
—
—
MMSKG2C
MMSKGJ2C
MMSKWN2C
MMSKW2C
—
—
MMSKG3
MMSKGJ3
MMSKWN3
—
—
—
—
MMSKG3A
MMSKGJ3A
MMSKWN3A
—
—
—
—
MMSKG3B
MMSKGJ3B
MMSKWN3B
—
—
—
—
MMSKG4
MMSKGJ4
MMSKWN4
—
—
—
—
MMSKSJ4B
MMSKG4B
MMSKGJ4B
MMSKWN4B
—
—
—
—
MMSKSJ4C
MMSKG4C
MMSKGJ4C
MMSKWN4C
—
—
—
—
—
—
—
Reversing Switch—Class MRS, Single Phase and 3-Phase
Type of
Operator
Number of
Poles
Suitable
Motor Types
Switch Features (Including
Mechanical Interlock)
2
Single Phase
3-Lead
Repulsion-Induction
3
3-Phase; Also
Single Phase Capacitor,
Split Phase, or 4-Lead
Repulsion-Induction
Standard
Red Pilot Device—115V AC
Red Pilot Device— 230V AC
Standard
Red Pilot Light—110–120V AC
Red Pilot Light—208–220V AC
Red Pilot Light—440–600V AC
Toggle
General Purpose
Flush Mounting
NEMA Type 1
Open Switch with Flush Plate General Purpose
(No Enclosure Provided)
Enclosure Surface Mounting
Catalog Number List Price $ Catalog Number List Price $
MRSKF11
MRSKF11A
MRSKF11B
MRSKF22
MRSKF22A
MRSKF22B
MRSKF22C
MRSKG11
MRSKG11A
MRSKG11B
MRSKG22
MRSKG22A
MRSKG22B
MRSKG22C
Replacement Switch
Class MRS
Catalog Number List Price $
MRSK01T
MRSK01AT
MRSK01BT
MRSK02T
MRSK02AT
MRSK02BT
MRSK02CT
Two Speed Switch—Class MMS, Single Phase and 3-Phase
Type of
Operator
Suitable
Motor Types
Switch Features (Including
Mechanical Interlock)
2
Single Phase
Two Winding
(3-Lead)
3
3-Phase
Separate Winding
(Wye-Connected)
Standard
(2) Red Pilot Devices—115V AC
(2) Red Pilot Devices—230V AC
Standard
(2) Red Pilot Lights—208–240V AC
(2) Red Pilot Lights—440–600V AC
Number of
Poles
Toggle
Manual switches do not include overloads.
Furnished with (1) 3/4" NPT outlet in bottom
(reversible
for top feed). In order to obtain a 3⁄4" NPT outlet in top
and bottom, add suffix letter “H” to type number with
List Price adder.
8/8
General Purpose
Flush Mounting
NEMA Type 1
Open Switch with Flush Plate General Purpose
(No Enclosure Provided)
Enclosure Surface Mounting
Catalog Number List Price $ Catalog Number List Price $
MMSKF11
MMSKF11A
MMSKF11B
MMSKF22
MMSKF22B
MMSKF22C
Do
not use as replacement interiors for NEMA Type 4
metallic enclosures. For replacement unit, order
Type MMSK01 or MMSK02 and separate pilot light kit.
Product Category: NEMA
MMSKG11
MMSKG11A
MMSKG11B
MMSKG22
MMSKG22B
MMSKG22C
Replacement Switch
Class MRS
Catalog Number List Price $
MRSK01T
MRSK01AT
MRSK01BT
MRSK02T
MRSK02BT
MRSK02CT
For
switches that contain a pilot light, a Red light is
standard. For a Green pilot light add ”G” to the end
of the catalog number.
Siemens Industry, Inc.
Industrial Controls Catalog
Manual Control
Starters and Switches, Class 11 - 3RV
General
Class 11 - 3RV
Class 11 across the line manual
starters and switches provide control
for machinery where remote start stop
control is not required.
Class 11 - 3RV manual starters are
used for single and poly-phase motors
up to 20HP @ 575V. Starters have
bimetallic heater elements to provide
class 10 overcurrent protection. Each
starter has a fourth bimetallic strip that
reacts only to the ambient temperature
inside the control panel. This ambient
compensation helps prevent the starter
from nuisance tripping when the panel
temperature is higher than the ambient
temperature of the motor.
A built-in differential trip bar causes the
starter to trip faster on a phase loss
condition to help reduce motor damage.
Magnetic trip elements in each starter
take the device off line when it senses
current of 13 times the maximum FLA
dial setting.
Class 11 - 3RV switches provide
control for inherently protected motors.
Typical applications include metal and
woodworking machinery, grinders,
power saws, conveyors, fans, pumps,
OPEN TYPE
Starter
Siemens Industry, Inc.
Industrial Controls Catalog
blowers, textile and packaging
machinery, and paper cutters.
Each switch is provided with magnetic
trip elements which take the device off
line when it senses current of 13 times
the maximum switch rating.
Class 11 - 3RV manual starters can be
used as Type E self-protected manual
combination starters (up to 22 amps)
per UL508 or as components in
Group Installation per NEC 430.53.
When using the Class 11 - 3RV as a
manual combination starter upstream
protection is not required.
Class 11 - 3RV controllers are available
with low voltage protection which will
automatically open the power poles
when the voltage drops or the power
is interrupted.
Controllers with the LVP option provide
the OSHA requirements for protecting
personnel from potential injury caused
by the automatic start-up of machinery
following a voltage drop or power
interruption when low voltage
protection is specified.
NEMA 1
General Purpose
Class 11 - 3RV is available as Open
style, or in NEMA 1, NEMA 7 & 9 or
NEMA 7 & 9 / 3 & 4 enclosures.
Standard Features include:
▪ ON/OFF rotary handle with lockout
and visible trip indication
▪ Adjustment dial for setting to motor
FLA (Starters only)
▪ Low Voltage Protection (LVP) Option
▪ Short Circuit trip at 13 times the
maximum setting of the FLA dial
or rated current
▪ Ambient compensated up to 140°F
▪ Phase loss sensitivity
▪ Test trip function
▪ LVP Option Meets OSHA
Requirements
▪ UL Listed
▪ CSA Certified
NEMA 7 & 9
Div 1 & Div 2
Class I Group C & D
Class II Group E, F & G
NEMA 3 & 4, NEMA 7 & 9
Div 1 & Div 2
Class I Group C & D
Class II Group E, F & G
8/9
Manual Control
Starters and Switches, Class 11 - 3RV
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
Low Voltage Protection Coil Table
No heaters required.
Field modification kits see page 8/80.
Dimensions see page 8/102.
Wiring Diagrams see page 8/130.
For applications requiring a low voltage protection coil
see table at right.
60 Hz Voltage
Letter
120V
208V
240V
460V
*F
*D
*G
*H
*Add corresponding letter to end of base Class 11
catalog number for low voltage protection coil with
List Price adder.
Note: The LVP option for Open type 3RV is available
from the factory, please order separately from the
field modification kits on page 8/81.
Class 11 Manual Motor Starter
The coil voltage should correspond with the
line voltage.
Manual Starter—Class 11 - 3RV
FLA
Adjustment
Range
0.11-0.16
0.14-0.2
0.18-0.25
0.22-0.32
0.28-0.4
0.35-0.5
0.45-0.63
0.55-0.8
0.7-1
0.9-1.25
1.1-1.6
1.4-2
1.8-2.5
2.2-3.2
2.8-4
3.5-5
4.5-6.3
5.5-8
7-10
9-12.5
11-16
14-20
17-22
20-25
Max HP
Enclosure
Single Phase
3-Phase
Open Type
HP Ratings
HP Ratings
115V
230V
200V
230V
460V
575V
Catalog Number
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1
1
1
1
3
3
1
1 1⁄2
2
3
3
5
5
7 1⁄2
7 1⁄2
1
1
1 1⁄2
2
3
3
5
7 1⁄2
7 1⁄2
7 1⁄2
1
1 1⁄2
1 1⁄2
2
3
5
5
7 1⁄2
7 1⁄2
10
15
15
15
1
1 1⁄2
1 1⁄2
2
3
3
5
5
10
10
15
20
20
20
3RV1021-0AA10
3RV1021-0BA10
3RV1021-0CA10
3RV1021-0DA10
3RV1021-0EA10
3RV1021-0FA10
3RV1021-0GA10
3RV1021-0HA10
3RV1021-0JA10
3RV1021-0KA10
3RV1021-1AA10
3RV1021-1BA10
3RV1021-1CA10
3RV1021-1DA10
3RV1021-1EA10
3RV1021-1FA10
3RV1021-1GA10
3RV1021-1HA10
3RV1021-1JA10
3RV1021-1KA10
3RV1021-4AA10
3RV1021-4BA10
3RV1021-4CA10
3RV1021-4DA10
1
⁄10
1
⁄8
1
⁄6
1
⁄4
1
⁄3
1
⁄2
1
⁄2
1
1 1⁄2
2
2
1
⁄10
⁄8
1
⁄6
1
⁄4
1
⁄3
1
⁄2
3
⁄4
1
1
1 1⁄2
2
3
3
3
5
⁄2
⁄4
3
⁄4
⁄2
⁄4
⁄2
3
⁄4
3
⁄4
1
⁄2
⁄2
3
⁄4
NEMA 1
NEMA 7 & 9
NEMA 3 & 4, NEMA 7 & 9
General Purpose
Class I Groups C & D
Class II Groups E, F & G
Watertight (Outdoor use)
Class I Groups C & D
Class II Groups E, F & G
List Price $ Catalog Number List Price $. Catalog Number List Price $
Catalog Number List Price $
11AD3B
11BD3B
11CD3B
11DD3B
11ED3B
11FD3B
11GD3B
11HD3B
11JD3B
11KD3B
11LD3B
11MD3B
11ND3B
11PD3B
11QD3B
11RD3B
11SD3B
11TD3B
11UD3B
11VD3B
11WD3B
11XD3B
11YD3B
11ZD3B
11AD3H
11BD3H
11CD3H
11DD3H
11ED3H
11FD3H
11GD3H
11HD3H
11JD3H
11KD3H
11LD3H
11MD3H
11ND3H
11PD3H
11QD3H
11RD3H
11SD3H
11TD3H
11UD3H
11VD3H
11WD3H
11XD3H
11YD3H
11ZD3H
11AD3W
11BD3W
11CD3W
11DD3W
11ED3W
11FD3W
11GD3W
11HD3W
11JD3W
11KD3W
11LD3W
11MD3W
11ND3W
11PD3W
11QD3W
11RD3W
11SD3W
11TD3W
11UD3W
11VD3W
11WD3W
11XD3W
11YD3W
11ZD3W
NEMA 1
NEMA 7 & 9
NEMA 3 & 4, NEMA 7 & 9
General Purpose
Class I Groups C & D
Class II Groups E, F & G
Watertight
Class I Groups C & D
Class II Groups E, F & G
Manual Switch—Class 11 - 3RV
Rated
Current
1
5
10
20
25
Max HP
Enclosure
Single Phase
3-Phase
Open Type
HP Ratings
HP Ratings
115V
230V
200V
230V
—
—
1
6
1
2
2
1 1⁄2
3
5
—
1
3
5
7 1⁄2
—
1
3
7 1⁄2
7 1⁄2
⁄
1
⁄2
1 1⁄2
Instantaneous
⁄
460V
575V
Catalog Number
1
2
1
2
3
7 1⁄2
15
15
3
10
20
20
3RV1321-0JC10
3RV1321-1FC10
3RV1321-1JC10
3RV1321-4BC10
3RV1321-4DC10
⁄
Magnetic Trip will occur at 13 times
the maximum FLA dial setting or rated switch current.
Product Category: IEC
8/10
⁄
List Price $. Catalog Number List Price $ Catalog Number List Price $
111D3B
112D3B
113D3B
114D3B
115D3B
Shaded
Ratings apply for Manual Motor Controllers
Only! These Ratings do not apply as UL Listed Manual
Combination Starters.
Product Category: NEMA
111D3H
112D3H
113D3H
114D3H
115D3H
Catalog Number List Price $
111D3W
112D3W
113D3W
114D3W
115D3W
Add
1 to the end of the catalog number for 1/2 inch drain
hole with plug and list price adder. Drain fitting not supplied, order separately XDB-2.
Siemens Industry, Inc.
Industrial Controls Catalog
Heavy Duty Control
Catalog Numbering System
General
ESP 200®
Current Range
Three Phase
A
B
C
D
E
Model
F
G
U — ESP200 size 0–4
H
& size 7 & 8
J
P — Thermal size 0–31⁄2,
K
Solid state size 5 & 6
L
M
N
Class
17 — Combination Starter
Size
(Non Fusible, Fusible)
B
C
D
E
F
G
H
I
J
L
M
N
P
18 — Combination Starter
(Circuit Breaker)
25 — Reversing
Combination Starter
(Non Fusible, Fusible)
26 — Reversing
Combination Starter
(Circuit Breaker)
—
—
—
—
—
—
—
—
—
—
—
—
—
00
0
1
13⁄4
2
21⁄2
3
31⁄2
4
5
6
7
8
—
—
—
—
—
—
—
—
—
—
—
—
—
0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200
100–300 w/ CT’s
133–400 w/ CT’s
200–600 w/ CT’s
250–750 w/ CT’s
400–1200 w/ CT’s
Breaker HP Code
Horsepower Rating
200, 230, 460, 575
A —
B —
C —
D —
E —
F —
G —
H —
J —
K —
L —
M —
N —
P —
R —
Enclosure Size
92 — Standard Width
82 — Extra Wide
Enclosure Type
B
F
H
N
W
—
—
—
—
—
NEMA
NEMA
NEMA
NEMA
NEMA
Pilot Control Circuit
14 — Across the Line NEMA
2 — suitable for
Motor Starter
22 — Reversing NEMA Motor
Starter
40 — Across the Line NEMA
Magnetic Contactor
43 — Reversing NEMA Magnetic
Contactor
Class
Three Phase
00
0
1
13⁄4
2
21⁄2
3
31⁄2
4
5
6
7
8
Size
C —
Combination D —
E —
Reduced
F —
Voltage
G—
Starter
37 — Combination H —
I —
Reduced
J —
Voltage
L —
Starter
M—
N—
P —
36 — Non
Single
3-wire control
(NO aux.
contact incl.)
ESP 200®
Current Range
Size
—
—
—
—
—
—
—
—
—
—
—
—
—
Model
U — ESP200 size 00–4,
Size 7 & 8
P — Thermal size 00–4,
Solid state sizes 5 & 6
Model
U — ESP200
0
size 0–4
1
& size 7 & 8
13⁄4
P — Thermal
2
1
size 0–31⁄2
2 ⁄2
Solid state
3
size 5 & 6
31⁄2
4
5
6
7
8
phase ESP200 available on Class 14 Starters
only.
used on Class 17, 25 or with ESP200 versions.
⁄2, 1⁄2,1, 1
1, 1, 3, 3
3, 3, 5, 5
3, 3, 71⁄2, 71⁄2
71⁄2, 71⁄2, 10, 10
—, —, 15, 15
10, 10, —, —
71⁄2, 10, 20, 20
10, 15, 25, 25
—, —, 30, 30
15, 20, —, —
—, —, 30, 30
25, 30, 50, 50
30, 40, 75, 75
40, 50, 100, 100
1
4X Fiberglass
7/9/3/4, Bolted (Class 18 & 26 only)
12 (Field convertible to 3/3R/4)
4/4X 304 Stainless Steel
Class
B
C
D
E
F
G
H
I
J
L
M
N
P
1
A
B
C
D
E
F
G
H
J
K
L
M
N
Coil
A — 110–120V/220–240V@60Hz
110V/190–220V@50Hz
C — 220–240V/440–480V@60Hz
190–220V/380–440V@50Hz
D — 200–208V@60Hz
E — 550–600V@60Hz
—
—
—
—
—
—
—
—
—
—
—
—
—
0.25–1
550V@50Hz
0.75–3.4 Enclosure Size
F — 120V@60Hz
3–12
110V@50Hz
1 — 2 power poles,1-phase
5.5–22
G — 220–240V@60Hz
3 — 3 power poles, 3-phase
10–40
190–220V@50Hz
8 — 3 power poles, 3-phase,
13–52
H — 440–480V@60Hz
extra wide enclosure
25–100
380–440V@50Hz
50–200
J — 24V@60Hz
100–300 w/ CT’s
24V@50Hz
133–400 w/ CT’s
L — 277V@60Hz
200–600 w/ CT’s
240V@50Hz
250–750 w/ CT’s
Enclosure Type
400–1200 w/ CT’s
A — Open
Single Phase
B — NEMA 1
F — NEMA 4X Fiberglass
A — 0.25–1
H — NEMA 7/9/3/4, Bolted
B — 0.75–3.4
(Class 18 & 26 only)
C — 3–12
0 — NEMA 12 (Field convertible to 3/3R/4)
D — 5.5–22
W — NEMA 4/4X 304 Stainless Steel
ESP 200®
Current Range Type
T — Auto XFMR
P — Part Wind.
0 — Wye Delta
Open Trans.
C — Wye Delta
Closed Trans.
Not available on sizes
For Class 37 only.
5–8.
Line Volts
Enclosure Type
2
3
4
5
6
A — Open
B — NEMA 1
W — NEMA 4/4X
—
—
—
—
—
230
380
460
575
200/208
Coil Disconnect Type
D
E
F
Stainless Steel G
0 — NEMA 12
H
L
D — Non Fused Disc.
F — Fusible Disc.
P — MCP
Position used for ESP200 only.
Not available on sizes 7 and 8.
Not
Siemens Industry, Inc.
Industrial Controls Catalog
8/11
Heavy Duty Starters
Features and Benefits
General
NEMA starters are ideal for
applications requiring dependability
and durability. Typical applications
include use with machine tools, air
conditioning equipment, material
handling equipment, compressors,
hoists and various production and
industrial equipment as well as in
demanding automotive applications.
Starters are available as an open type
or in NEMA 1, 12/3/3R, 4 (painted), 4/4X
(stainless), 4X (fiberglass), and 7 & 9
enclosures.
Solid State Starter Class 14
Standard Features
Size 00–4 magnetic starters include the
following standard features:
▪ Rugged Industrial Design
▪ Half Sizes for Cost and Space Savings
▪ Dual Voltage, Dual Frequency Coils
▪ Solid State or Ambient Compensated
Bimetal Overload Protection
▪ Wide Range of Accessories
▪ Easy Coil Access
▪ Overload Test Feature
▪ Straight Thru Wiring
▪ Gravity Dropout
▪ Large Silver Cadmium Contacts
▪ UL listed file #E14900 (class 14, 22,
30, 40 & 43)
▪ CSA certified file #LR 6535 (class 14,
22, 30, 40 & 43)
Application
Heavy Duty starters are designed for
across the line starting of single phase
and polyphase motors.
These controls are available in NEMA
Sizes 00 through 8. In addition to the
usual NEMA Starter Sizes, Siemens
offers three exclusive Half Sizes; 13⁄4,
21⁄2 and 31⁄2. These integral sizes offer
the same rugged, industrial
construction as our NEMA Sizes and
ensure efficient operating performance.
Half Sizes provide a real cost savings
by cutting down on over capacity when
NEMA Sizes exceed the motor ratings.
All Siemens Heavy Duty controls,
including our popular Half Sizes comply
with applicable NEMA and UL tests.
All starters are supplied with a NO
holding interlock that in conjunction
with an appropriate pilot device will
provide low voltage protection or
release.
8/12
are available to meet particular
application requirements
▪ Normally opened or normally closed
auxiliary power pole kits are available
for Sizes 00 through 13⁄4
▪ Transformers can be ordered as either
factory or field modifications.
In some cases these may require a
larger enclosure
▪ A full line of replacement parts are
available including contact kits, coils,
and overload relays
Gravity Dropout
For added reliability, the gravity dropout
of the armature and contacts is assisted
by stainless steel springs which help
provide quick, precise opening of the
contacts.
Part No
49D70084
45 Degree, Wedge Action Contacts
The 45 degree, wedge action contacts
reduce tracking and provide faster arc
quenching. The resulting self-cleaning
and reduced contact bounce mean
cooler operation and longer life for the
large silver cadmium oxide contacts.
Terminal Design
Control terminals are self-rising
pressure type.
Molded Coil
Magnetic coils are carefully wound and
then sealed in epoxy. Encapsulation
helps seal out moisture, promotes
heat transfer and resists electrical,
mechanical and thermal stresses.
Dual Voltage/Frequency Coil
Starters are available with dual voltage,
dual frequency coils. They are designed
to operate on either 50 or 60 Hertz.
Molded Stationary Contact Block
Thermoset materials resist arc tracking
and the stresses of heat and severe
impact.
Field Modification Kits
All starters can be modified in the field
with a complete range of accessories.
These include pushbuttons, selector
switches, pilot lights, auxiliary contacts
and surge suppressors.
Auxiliary Equipment
▪ NEMA starters are available with
built-in START-STOP push buttons
for 3-wire control or a
HAND-OFF-AUTO selector
switch for 2-wire control
▪ Field modifications such as auxiliary
contacts, pilot lights, push buttons,
selector switches, and fuse blocks
Siemens Sizes 00–13⁄4 have as
standard, universal mounting which
fits the following:
Cutler Hammer—Citation Series
—Freedom Series
GE
—300 Line
Square D
—Type S
The Starter with its existing
backplate mounts onto the piggyback
mounting plate and is secured in
place with three mounting screws.
The piggyback mounting plate fits
the following:
Allen-Bradley
—Bulletin 509
—Bulletin 709
Westinghouse —Series A200
Size 5 & 6 Starters
Additional Features
▪ Solid State Overload (3RB type)
Standard
▪ Latest technology in arc quenching to
extend contactor life
▪ Wide variety of enclosures in all
starter configurations
Size 7 & 8 Starters
Additional Features
▪ New Compact Design
▪ Can be mounted in any position
▪ Same coil voltage is AC or DC
Siemens Industry, Inc.
Industrial Controls Catalog
Heavy Duty Starters
Features and Benefits
General
Half Size Starters
Half-Size starters feature all the
rugged performance characteristics of
our NEMA rated starter sizes, but are
fractionally sized to more closely match
your exact motor rating. As a result,
significant economic savings are made
possible without sacrificing the reliability
you expect from a heavy duty starter.
ESP200™ Solid State Starter
ESP200™ starters combine the rugged
NEMA contactors with a state of the
art solid state overload that provides
phase loss, phase unbalance ground
fault protection. It offers the user
greater motor protection and extended
life in heavy duty applications. The
ESP200™ ultimately results in a cost
savings to the user.
ESP200™ Solid State Overload Relays
Standard features provide Improved
Starter Performance:
▪ True phase loss protection; trips
within 3 seconds
▪ Phase unbalanced prevents motor
running inefficiently
▪ Ground fault trip when selected
▪ Selectable trip class 5, 10, 20 or 30
▪ Reset trip can be selected
Auto/Manual restart
▪ Easy to select and use, Dip Switch
selectable
▪ Overload is self powered, no need for
external power source
These additional starter sizes have the
reserve capacity to handle occasional
plugging and jogging applications
without derating. Superior operating
performance in heavy duty applications
is assured by the large current carrying
parts, not by derating the device.
Exclusive “half-sizes” save potentially
hundreds, even thousands of dollars
per project.
Using the table below, simply match
the specific size starter to the
horsepower rating of your motor.
Every half-size starter saves you
money—up to 31%.
DIP Switch Settings
Adjust DIP switch settings to the Trip
Class desired 5, 10, 20, or 30.
▪
▪
▪
▪
Set Phase Unbalance ON or OFF
Set Phase Loss ON or OFF
Set Reset to Manual or Automatic
Set Ground Fault ON or OFF
All “half-sizes” comply to applicable
NEMA and UL standards.
ESP200® FLA Adjustment Dial—Set the
adjustment dial on the overload to the
FLA of the motor.
Figure 1
Typical Solid-State Overload
Adjustment Dial Markings
Each overload is precisely calibrated
and labels are laser printed.
Savings for Siemens “Half-Size” Starters in NEMA 1 Enclosures, FVNR
Motor Size
230V
7 ⁄
460V
Starter
Size
Half
Size
List Price $
“Half-Size”
Savings Over
Next Full Size
10
1
—
—
10
15
—
13⁄4
31%
15
25
2
—
—
20
30
—
2⁄
20%
30
50
3
—
—
12
12
40
75
—
31⁄2
13%
50
100
4
—
—
Siemens Industry, Inc.
Industrial Controls Catalog
Product Category: NEMA
Standard Auxiliary Contacts
Type
All FVNR
Starters &
Contactors
Size (3rd Character)
Configuration
B Thru E
1N.O.
Internal / External
Internal
F Thru J
1N.O.
External
L Thru M
2N.O., 2N.C.
External
N Thru P
1N.O., 1N.C.
External
8/13
Heavy Duty Motor Starters
Solid State Overload with Auto/Manual Reset, Class 14
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/103 open and 8/116 enclosed.
Wiring Diagrams see page 8/131.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
Open Type
Overload
200
Volts
1
⁄6
1
⁄2
11⁄2
1
⁄6
1
⁄2
2
3
1
⁄6
1
⁄2
2
3
71⁄2
10
10
15
25
30
40
75
150
—
—
230
Volts
1
⁄6
3
⁄4
11⁄2
1
⁄6
3
⁄4
2
3
1
⁄6
3
⁄4
2
3
71⁄2
10
15
20
30
40
50
100
200
300
450
460
Volts
1
⁄3
11⁄2
2
1
⁄3
11⁄2
5
—
1
⁄3
11⁄2
5
10
—
15
25
30
50
75
100
200
400
600
900
575
Volts
1
⁄2
2
—
1
⁄2
2
5
—
1
⁄2
2
5
10
—
15
25
30
50
75
100
200
400
600
900
NEMA Half
Size Size
00
—
00
—
00
—
0
—
0
—
0
—
0
—
1
—
1
—
1
—
1
—
1
—
—
13⁄4
2
—
—
21⁄2
3
—
—
31⁄2
4
—
5
—
6
—
7
—
8
—
Amp
Range
0.25–1
0.75–3.4
3–12
0.25–1
0.75–3.4
3–12
5.5–22
0.25–1
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
160–630
400–1220
400–1220
Frame
Size
A
A
A1
A
A
A1
A1
A
A
A1
A1
A1
A1
B
B
B
B
B
—
—
A1+CT
A1+CT
NEMA 4/4X Stainless NEMA 4X
Watertight, Dust-tight,
Fiberglass
NEMA 1
Standard Auxiliary
Contacts
General Purpose
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel
Optional)
Watertight, Dust-tight
Corrosion Resistant
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Div. 1 and Div. 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
Catalog
List
Catalog
List
Catalog
List
Catalog
List
Catalog
List
Number
Price $ Number
Price $ Number
Price $ Number
Price $ Number
Price $
14BUA32A*
14BUA32B*
Use Size 0
Use Size 0
Use Size 0
—
—
—
14BUB32A*
14BUB32B*
Use Size 0
Use Size 0
Use Size 0
—
—
—
14BUC32A*
14BUC32B*
Use Size 0
Use Size 0
Use Size 0
—
—
—
14CUA32A*
14CUA32B*
14CUA32W*
14CUA32F*
14CUA32H*
14CUB32A*
14CUB32B*
14CUB32W*
14CUB32F*
14CUB32H*
14CUC32A*
14CUC32B*
14CUC32W*
14CUC32F*
14CUC32H*
14CUD32A*
14CUD32B*
14CUD32W*
14CUD32F*
14CUD32H*
14DUA32A*
14DUA32B*
14DUA32W*
14DUA32F*
14DUA32H*
14DUB32A*
14DUB32B*
14DUB32W*
14DUB32F*
14DUB32H*
14DUC32A*
14DUC32B*
14DUC32W*
14DUC32F*
14DUC32H*
14DUD32A*
14DUD32B*
14DUD32W*
14DUD32F*
14DUD32H*
14DUE32A*
14DUE32B*
14DUE32W*
14DUE32F*
14DUE32H*
14EUE32A*
14EUE32B*
14EUE32W*
14EUE32F*
14EUE32H*
14FUF32A*
14FUF32B*
14FUF32W*
14FUF32F*
14FUF32H*
14GUG32A*
14GUG32B*
14GUG32W*
14GUG32F*
14GUG32H*
14HUG32A*
14HUG32B*
14HUG32W*
14HUG32F*
14HUG32H*
14IUH32A*
14IUH32B*
14IUH32W*
14IUH32F*
14IUH32H*
14JUH32A*
14JUH32B*
14JUH32W*
14JUH32F*
14JUH32H*
14LPU32A*
14LPU32B*
14LPU32E*
14LPU32H*
—
—
14MPX32A*
14MPX32B*
14MPX32E*
—
—
—
—
14NUN32A*
14NUN32B*
14NUN32E*
—
—
—
—
14PUN32A*
14PUN32B*
14PUN32E*
—
—
—
—
Catalog
List
Number
Price $
Use Size 0
—
Use Size 0
—
Use Size 0
—
14CUA320*
14CUB320*
14CUC320*
14CUD320*
14DUA320*
14DUB320*
14DUC320*
14DUD320*
14DUE320*
14EUE320*
14FUF320*
14GUG320*
14HUG320*
14IUH320*
14JUH320*
14LPU320*
14MPX320*
14NUN320*
14PUN320*
Open Type & Standard Width Enclosure, Single Phase, 2-Pole
Max Hp
Enclosure
Open Type
Overload
Standard Auxiliary
Contacts
115
Volts
1
⁄8
1
⁄4
1
1
⁄8
1
⁄4
1
208/
230
Volts
1
⁄4
1
⁄2
2
1
⁄4
1
⁄2
2
NEMA
Size
0
0
0
1
1
1
Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
Frame
Size
A
A1
A1
A
A1
A1
Catalog
Number
14CUB12A*
14CUC12A*
14CUD12A*
14DUB12A*
14DUC12A*
14DUD12A*
NEMA 4/4X Stainless NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight,
Watertight, Dust-tight
Corrosion Resistant
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
List
Catalog
Price $ Number
14CUB12B*
14CUC12B*
14CUD12B*
14DUB12B*
14DUC12B*
14DUD12B*
Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
Dual voltage coils not available in size 5–8 starters.
For conduit hubs and conversion instructions, see
page 8/88.
8/14
NEMA 1
List
Catalog
Price $ Number
14CUB12W*
14CUC12W*
14CUD12W*
14DUB12W*
14DUC12W*
14DUD12W*
List
Catalog
Price $ Number
14CUB12F*
14CUC12F*
14CUD12F*
14DUB12F*
14DUC12F*
14DUD12F*
Coils
D, F, or G will be wired for incoming voltage. J coil
will be wired for separate source. Coils E, H, and L do
not apply to single phase starters.
Enclosure is NEMA Type 4 (painted steel).
F coil 100-250V AC 50/60Hz, or DC,
H coil 150-500V AC 50/60Hz, or DC
Only available F coil100-250V AC 50/60Hz, or DC
Product Category: NEMA
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Div. 1 and Div. 2 Class I
Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Catalog
Price $ Number
14CUB12H*
14CUC12H*
14CUD12H*
14DUB12H*
14DUC12H*
14DUD12H*
List
Catalog
Price $ Number
14CUB120*
14CUC120*
14CUD120*
14DUB120*
14DUC120*
14DUD120*
List
Price $
Standard
Auxiliary Contacts, Same as Contactors,
refer to page 8/13.
Steel option see page 8/98.
with the ESP200 OLR will not be available until approximately December 2009. Continue to
order enclosed starters with the ESP100 OLR until then.
For 316 Stainless
Enclosed starters
Siemens Industry, Inc.
Industrial Controls Catalog
Heavy Duty Motor Starters
Solid State Overload with Auto/Manual Reset, Class 14
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/116.
Wiring Diagrams see page 8/131.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
NEMA 1
Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp
200
Volts
Enclosure
Overload
230
Volts
460
Volts
NEMA 1
NEMA 4/4X Stainless
General Purpose
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
575
Volts
NEMA
Size
Half Amp
Size Range
Frame
Size
Catalog
Number
List
Price $
Catalog
Number
List
Price $
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Div. 1 and Div. 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
Catalog
Number
Catalog
Number
List
Price $
List
Price $
⁄6
1
⁄6
1
⁄3
1
⁄2
00
—
0.25–1
A
14BUA82B*
Use Size 0
—
Use Size 0
—
Use Size 0
—
1
⁄2
3
⁄4
11⁄2
2
00
—
0.75–3.4
A
14BUB82B*
Use Size 0
—
Use Size 0
—
Use Size 0
—
11⁄2
11⁄2
2
—
00
—
3–12
A1
14BUC82B*
Use Size 0
—
Use Size 0
—
Use Size 0
—
⁄6
1
⁄3
1
⁄2
0
—
0.25–1
A
14CUA82B*
14CUA82W*
14CUA82H*
14CUA820*
1
⁄6
1
1
⁄2
3
⁄4
11⁄2
2
0
—
0.75–3.4
A
14CUB82B*
14CUB82W*
14CUB82H*
14CUB820*
2
2
5
5
0
—
3–12
A1
14CUC82B*
14CUC82W*
14CUC82H*
14CUC820*
3
3
—
—
0
—
5.5–22
A1
14CUD82B*
14CUD82W*
14CUD82H*
14CUD820*
⁄6
1
1
⁄2
1
⁄6
1
⁄3
1
⁄2
1
—
0.25–1
A
14DUA82B*
14DUA82W*
14DUA82H*
14DUA820*
3
⁄4
11⁄2
2
1
—
0.75–3.4
A
14DUB82B*
14DUB82W*
14DUB82H*
14DUB820*
2
2
5
5
1
—
3–12
A1
14DUC82B*
14DUC82W*
14DUC82H*
14DUC820*
3
3
10
10
1
—
5.5–22
A1
14DUD82B*
14DUD82W*
14DUD82H*
14DUD820*
71⁄2
71⁄2
—
—
1
—
10–40
A1
14DUE82B*
14DUE82W*
14DUE82H*
14DUE820*
10
10
15
15
—
13⁄4
10–40
A1
14EUE82B*
14EUE82W*
14EUE82H*
14EUE820*
10
15
25
25
2
—
13–52
B
14FUF82B*
14FUF82W*
14FUF82H*
14FUF820*
15
20
30
30
—
21⁄2
25–100
B
14GUG82B*
14GUG82W*
14GUG82H*
14GUG820*
25
30
50
50
3
—
25–100
B
14HUG82B*
14HUG82W*
14HUG82H*
14HUG820*
30
40
75
75
—
31⁄2
50–200
B
14IUH82B*
14IUH82W*
14IUH82H*
14IUH820*
1
Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
For
conduit hubs and conversion instructions, see
page 8/88.
For
Siemens Industry, Inc.
Industrial Controls Catalog
316 Stainless Steel option see page 8/98.
Product Category: NEMA
Enclosed
starters with the ESP200 OLR will not be available until approximately December 2009. Continue to
order enclosed starters with the ESP100 OLR until then.
8/15
Heavy Duty Motor Starters
Ambient Compensated Bimetal Overload with Manual and Auto Reset, Class 14
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. Single phase starters require 1 heater
element. 3-phase starters require 3 heater elements.
Field Modification Kits page 8/82.
Factory Modifications page 8/95.
Dimensions see page 8/104 open and 8/116 enclosed.
Wiring Diagrams see page 8/131.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
200
Volts
230
Volts
460
Volts
575
Volts
Contactor
Amp
NEMA Half
Rating Size
Size
1 1⁄2
3
7 1⁄2
10
10
15
25
30
40
1 1⁄2
3
7 1⁄2
10
15
20
30
40
50
2
5
10
15
25
30
50
75
100
2
5
10
15
25
30
50
75
100
9
18
27
40
45
60
90
115
135
00
0
1
—
2
—
3
—
4
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
Open Type
NEMA 1
Standard Auxiliary
Contacts
General Purpose
NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight
NEMA 3 & 4
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Corrosion Resistant
NEMA 12
NEMA 3/3R
Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Industrial Use
Weatherproof
Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $
14BP32A*81
14CP32A*81
14DP32A*81
14EP32A*81
14FP32A*81
14GP32A*81
14HP32A*81
14IP32A*81
14JG32A*81
14BP32B*81
14CP32B*81
14DP32B*81
14EP32B*81
14FP32B*81
14GP32B*81
14HP32B*81
14IP32B*81
14JG32B*81
Use Size 0
—
14CP32W*81
14DP32W*81
14EP32W*81
14FP32W*81
14GP32W*81
14HP32W*81
14IP32W*81
14JG32W*81
Use Size 0
14CP32F*81
14DP32F*81
14EP32F*81
14FP32F*81
14GP32F*81
14HP32F*81
14IP32F*81
14JG32F*81
—
Use Size 0 —
14CP32H*81
14DP32H*81
14EP32H*81
14FP32H*81
14GP32H*81
14HP32H*81
14IP32H*81
14JG32H*81
Use Size 0 —
14CP320*81
14DP320*81
14EP320*81
14FP320*81
14GP320*81
14HP320*81
14IP320*81
14JG320*81
Open Type & Standard Width Enclosure, Single Phase, 2-Pole
Max Hp
Enclosure
Open Type
NEMA 1
General Purpose
NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight
Watertight, Dust-tight
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Corrosion Resistant
304 Stainless Steel
Industrial Use
Weatherproof
Corrosion Resistant
Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
115
Volts
208/230
Volts
Contactor
Amp
NEMA
Rating
Size
Half
Size
Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $
1
1
2
3
5
7 1⁄2
10
9
18
27
35
45
60
—
—
—
—
—
21⁄2
14BP12A*81
14CP12A*81
14DP12A*81
14EP12A*81
14FP12A*81
14GP12A*81
⁄3
1
2
3
3
5
00
0
1
1P
2
—
14BP12B*81
14CP12B*81
14DP12B*81
14EP12B*81
14FP12B*81
14GP12B*81
Use Size 0
14CP12W*81
14DP12W*81
14EP12W*81
14FP12W*81
14GP12W*81
—
Use Size 0
14CP12F*81
14DP12F*81
14EP12F*81
14FP12F*81
14GP12F*81
—
Use Size 0
14CP12H*81
14DP12H*81
14EP12H*81
14FP12H*81
14GP12H*81
—
Use Size 0
14CP120*81
14DP120*81
14EP120*81
14FP120*81
14GP120*81
—
Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp
200
Volts
1 1⁄2
3
7 1⁄2
10
10
15
25
30
40
230
Volts
1 1⁄2
3
7 1⁄2
10
15
20
30
40
50
Enclosure
460
Volts
2
5
10
15
25
30
50
75
100
575
Volts
2
5
10
15
25
30
50
75
100
NEMA 4/4X Stainless
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Contactor
Amp
NEMA Half
Rating
Size
Size Catalog No
9
00
— 14BP82B*81
18
0
— 14CP82B*81
27
1
— 14DP82B*81
40
—
1 3⁄4 14EP82B*81
45
2
— 14FP82B*81
60
—
2 1⁄2 14GP82B*81
90
3
— 14HP82B*81
115
—
3 1⁄2 14IP82B*81
135
4
— 14JG82B*81
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All Starter Sizes carry
one maximum Hp rating. For higher Hp single
phase motors, use 3-phase starters, wire and set
per diagram on page 8/131.
8/16
NEMA 1
List Price $
Catalog No
Use Size 0
14CP82W*81
14DP82W*81
14EP82W*81
14FP82W*81
14GP82W*81
14HP82W*81
14IP82W*81
14JG82W*81
To
List Price $
—
receive a single phase starter in an extra wide
enclosure, order the enclosure kit from pg 8/91 and the
open style starter from pg 8/14 or 8/16 as
separate items.
For conduit hubs and conversion instructions, see
page 8/88.
Product Category: NEMA
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Div 1 and Div 2
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Industrial Use
Weatherproof
Catalog No
Use Size 0
14CP82H*81
14DP82H*81
14EP82H*81
14FP82H*81
14GP82H*81
14HP82H*81
14IP82H*81
14JG82H*81
Catalog No
Use Size 0
14CP820*81
14DP820*81
14EP820*81
14FP820*81
14GP820*81
14HP820*81
14IP820*81
14JG820*81
List Price $
—
List Price $
—
Coils
D, F, or G will be wired for incoming voltage.
J coil will be wired for separate source. Coils E, H,
and L do not apply to single phase starters.
Standard Auxiliary Contacts, Same as Contactors,
refer to page 8/44.
For 316 Stainless Steel option see page 8/98.
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Heavy Duty Starters
Features and Benefits
General
Combination Starter
Features
Combination starters include
the following features:
▪ Manufactured with Cold Forming
“TOX” Process
▪ Solid State Overloads Standard on
Sizes 5–8
▪ Easy to Install
▪ Wide Range of Enclosure Types
Available
▪ Heavy Duty Quarter Turns
▪ 100kA Short Circuit Current Rating
when Protected with Class R Fuses
to 600V or MCP to 480V
▪ Visible Blade Disconnect
▪ Industrial Type Disconnect Handle
▪ UL listed file #E185287 (class 17, 18,
25, 26 & 32)
▪ CSA certified file #LR 6535 (class 17,
18, 25, 26 & 32)
Application
A combination starter meets National
Electrical Code requirements for:
(stainless), 4X fiberglass and 7 & 9
enclosures. Enclosures protect
personnel from contact with live parts
and depending upon the construction,
protect the control in varying degrees
from physical damage and harmful
atmospheres. All enclosures are
supplied with corrosion resistant
finishes.
Simply start with the enclosure kit
which has the handle preinstalled. You
install the required starter and fusible
disconnect, connect the power wire
and you are finished. Within minutes,
you have the required combination
starter in your hands. No more waiting
on the factory. You need it, your got it!
Heavy Duty Disconnect Switches
▪ Reduce Lead-time - What used to
take days to get now takes minutes
▪ Reduced Inventory - Instead of
stocking scores of various combination starters, simply stock a few
enclosure kits, disconnect kits, circuit
breaker kits and open starters. With
these basic “building blocks” you
virtually have hundreds of products
on-hand
▪ Quality - The same high level of
quality you have been accustomed
to with our products will also be
found in these new enclosure kits
▪ UL Listed - By correctly following
the instructions included with the kits,
the product you build is
UL/CSA Listed
Refer to page 8/93 for more details.
Siemens Type ETI Circuit Breaker
The ETI circuit breaker is a device
designed specifically for application
in motor circuits. The ETI is a magnetic
only protective device designed to
provide protection against short
circuit current.
The disconnect switch that goes the
distance in durability, performance and
reliability has the following advantages:
▪ Visible blades for the highest level
of safety
▪ Double break switching action to
reduce arcing, increase lifetime and
eliminate the “electric hinge”
▪ More rugged positive action switch
▪ Oversized lugs are standard
▪ Line side shield to help guard
personnel from contact with live parts
▪ Higher horsepower rating for
design E high efficiency motors
▪ UL listed for IIsco, Burndy and T&B
crimp type lugs
▪ The 200A switch accepts up to 300
MCM versus 250 MCM wire size
Its rugged construction - with a high
fault withstand rating of 100kA at 600
VAC when fused with class R rated
fuses - meets the most stringent
industry standards set forth by the
automotive, petro-chemical, and pulp
and paper industries. UL recognized and
CSA certified, our disconnect switches
are available either non-fusible or fusible
with class R and class J fuse clips.
1. A means of providing short circuit
What Is In It For You!
The instantaneous-only type ETI circuit
breaker employs adjustable magnetic
trip settings to allow broader application
ranges and a higher degree of motor
short circuit protection.
motor protection with fused or breaker
disconnection of line voltage.
2. A means of safeguarding personnel
from contact with live parts and from
accidental starting of machinery by
disconnecting the motor and the
controller.
3. A motor controller with overload
protection.
Prewired combination starters eliminate
the cost of wiring between separate
disconnect and starter. Factory testing
assures field performance. Combination
starters also provide a more compact
and attractive installation than separate
units.
Enclosure Types
Combination starters are available in
NEMA 1, 12/3/3R/4 (painted), 4/4X
Siemens Industry, Inc.
Industrial Controls Catalog
Enclosure Kits for NEMA
Combination Starters Description
You can assemble a non-stocked combination starter per your unanticipated
needs in minutes. Say, for example,
your customer needs a fusible combination starter that you don’t have in stock.
You need in now, but don’t sweat it.
Heavy Duty Starters
These combination starters use the
same starters described in the heavy
duty starter section of this catalog.
8/17
Combination Heavy Duty Starters
Non-Fusible with Solid State Overload, Class 17
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
For Fusible Styles see page 8/21.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Standard Width Enclosure, 3 Phase, 3-Pole
Max Hp
Enclosure
NEMA 1
Overload
NEMA 4/4X Stainless
General Purpose
200
Volts
230
Volts
460
Volts
575
Volts
NEMA Half
Size
Size
Amp
Range
Disc.
Frame Amp
Size
Range
Catalog
Number
1
⁄6
⁄2
2
3
1
⁄6
1
⁄2
2
3
71⁄2
10
10
15
20
30
40
75
150
—
—
1
⁄6
⁄4
2
3
1
⁄6
3
⁄4
2
3
71⁄2
10
15
20
25
40
50
100
200
300
450
1
3
⁄3
11⁄2
5
—
1
⁄3
11⁄2
5
10
—
15
25
30
50
75
100
200
400
600
900
1
1
⁄2
2
5
—
1
⁄2
2
5
10
—
15
25
30
50
75
100
200
400
600
900
0
0
0
0
1
1
1
1
1
—
2
—
3
—
4
5
6
7
8
0.25–1
0.75–3.4
3–12
5.5–22
0.25–1
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
160–630
400–1220
400–1220
A
A
A1
A1
A
A
A1
A1
A1
A1
B
B
B
B
B
—
—
A1+CT
A1+CT
17CUA92B*
17CUB92B*
17CUC92B*
17CUD92B*
17DUA92B*
17DUB92B*
17DUC92B*
17DUD92B*
17DUE92B*
17EUE92B*
17FUF92B*
17GUG92B*
17HUG92B*
17IUH92B*
17JUH92B*
17LPU92B*
17MPX92B*
17NUN92B*
17PUN92B*
—
—
—
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—
30
30
30
30
30
30
30
30
60
60
60
100
100
200
200
400
800
1200
1600
NEMA 4X Fiberglass
Watertight, Dust-tight,
Watertight, Dust-tight
Corrosion Resistant
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
List
Price $
Catalog
Number
List
Price $
17CUA92W*
17CUB92W*
17CUC92W*
17CUD92W*
17DUA92W*
17DUB92W*
17DUC92W*
17DUD92W*
17DUE92W*
17EUE92W*
17FUF92W*
17GUG92W*
17HUG92W*
17IUH92W*
17JUH92W*
17LPU92E*
17MPX92E*
—
—
Catalog
Number
—
—
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
17CUA92F*
17CUB92F*
17CUC92F*
17CUD92F*
17DUA92F*
17DUB92F*
17DUC92F*
17DUD92F*
17DUE92F*
17EUE92F*
17FUF92F*
17GUG92F*
17HUG92F*
17IUH92F*
17JUH92F*
—
—
—
—
NEMA 12
NEMA 3/3R
—
—
—
—
Catalog
Number
List
Price $
17CUA92N*
17CUB92N*
17CUC92N*
17CUD92N*
17DUA92N*
17DUB92N*
17DUC92N*
17DUD92N*
17DUE92N*
17EUE92N*
17FUF92N*
17GUG92N*
17HUG92N*
17IUH92N*
17JUH92N*
17LPU92N*
17MPX92N*
17NUN92N*
17PUN92N*
Standard Width Enclosure, Single Phase, (Catalog Numbers are three phase, wire for single phase in the field)
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
115
Volts
⁄8
⁄4
1
1
⁄8
1
⁄4
1
208
230
Volts
NEMA
Size
Half
Size
Amp
Range
Frame
Size
Disc.
Amp
Range
Catalog
Number
⁄4
⁄2
2
1
⁄4
1
⁄2
2
0
0
0
1
1
1
—
—
—
—
—
—
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
A
A1
A1
A
A1
A1
30
30
30
30
30
30
17CUB92B*
17CUC92B*
17CUD92B*
17DUB92B*
17DUC92B*
17DUD92B*
1
1
1
1
List
Price $
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Stee (Optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog
Number
Catalog
Number
List
Price $
17CUB92W*
17CUC92W*
17CUD92W*
17DUB92W*
17DUC92W*
17DUD92W*
17CUB92F*
17CUC92F*
17CUD92F*
17DUB92F*
17DUC92F*
17DUD92F*
Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
For
F
Dual
For
Only
voltage coils not available in modified starters or
in starter sizes 5–8.
conduit hubs and conversion instructions, see
page 8/88.
For 60A disconnect, order fusible cat. no. page 8/21.
For
8/18
25 HP and 200A disconnect, order fusible cat. no.
page 8/21.
30HP and 200A disconnect, order fusible cat. no.
page 8/21.
For 600A disconnect, order fusible cat. no. page 8/21.
Enclosure is NEMA Type 4 (painted steel).
For a single phase motor, multiply the motor
nameplate by 0.75 and set the OL dial to the
resulting value.
Product Category: NEMA
List
Price $
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
Catalog
Number
List
Price $
17CUB92N*
17CUC92N*
17CUD92N*
17DUB92N*
17DUC92N*
17DUD92N*
coil 100-250V AC 50/60Hz, or DC,
H coil 150-500V AC 50/60Hz, or DC
available
F coil 100-250V AC 50/60Hz, or DC
For 316 Stainless Steel option see page 8/98.
Enclosed starters with the ESP200 OLR will not be available until approximately December 2009. Continue to
order enclosed starters with the ESP100 OLR until then.
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Heavy Duty Starters
Non-Fusible with Solid State Overload, Class 17
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
For Fusible Styles see page 8/22.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Extra Wide Enclosure, 3-Phase, 3-Pole
Hp
200
Volts
Enclosure
Overload
230
Volts
460
Volts
NEMA 1
NEMA 4/4X Stainless
General Purpose
Watertight, Dust-tight, Corrosion
Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
575
Volts
NEMA
Size
Half
Size
Amp
Range
Frame
Size
Disc.
Amp
Range
Catalog
Number
List
Price $
Catalog
Number
List
Price $
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
Catalog
Number
⁄6
1
⁄6
1
⁄3
1
⁄2
0
—
0.25–1
A
30
17CUA82B*
17CUA82W*
17CUA82N*
1
⁄2
3
⁄4
11⁄2
2
0
—
0.75–3.4
A
30
17CUB82B*
17CUB82W*
17CUB82N*
2
2
5
5
0
—
3–12
A1
30
17CUC82B*
17CUC82W*
17CUC82N*
3
3
—
—
0
—
5.5–22
A1
30
17CUD82B*
17CUD82W*
17CUD82N*
⁄6
1
1
⁄2
1
⁄6
1
⁄3
1
⁄2
1
—
0.25–1
A
30
17DUA82B*
17DUA82W*
17DUA82N*
3
⁄4
11⁄2
2
1
—
0.75–3.4
A
30
17DUB82B*
17DUB82W*
17DUB82N*
2
2
5
5
1
—
3–12
A1
30
17DUC82B*
17DUC82W*
17DUC82N*
3
3
10
10
1
—
5.5–22
A1
30
17DUD82B*
17DUD82W*
17DUD82N*
71⁄2
71⁄2
—
—
1
—
10–40
A1
60
17DUE82B*
17DUE82W*
17DUE82N*
10
10
15
15
—
13⁄4
10–40
A1
60
17EUE82B*
17EUE82W*
17EUE82N*
10
15
25
25
2
—
13–52
B
60
17FUF82B*
17FUF82W*
17FUF82N*
15
20
30
30
—
21⁄2
25–100
B
100
17GUG82B*
17GUG82W*
17GUG82N*
20
25
50
50
3
—
25–100
B
100
17HUG82B*
17HUG82W*
17HUG82N*
1
Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
Dual voltage coils not available in modified starters.
For conduit hubs and conversion instructions, see
page 8/88.
Siemens Industry, Inc.
Industrial Controls Catalog
For
For
60A disconnect, order fusible cat. no. page 8/22.
25 HP and 200A disconnect, order fusible cat. no.
page 8/22.
For 30HP and 200A disconnect, order fusible cat. no.
page 8/22.
Product Category: NEMA
List
Price $
For 316 Stainless
Enclosed starters
Steel option see page 8/98.
with the ESP200 OLR will not be available until approximately December 2009. Continue to
order enclosed starters with the ESP100 OLR until then.
8/19
Combination Heavy Duty Starters
Non-Fusible with Ambient Compensated Bimetal Overload, Class 17
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. (3 required)
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
NEMA 1
General Purpose
200
Volts
3
71⁄2
10
10
15
25
30
40
230
Volts
3
71⁄2
10
15
20
30
40
50
460
Volts
5
10
15
25
30
50
75
100
575
Volts
5
10
15
25
30
50
75
100
Contactor
Amp
Rating
18
27
40
45
60
90
115
135
Disc
NEMA Half Amp
Size
Size Rating
0
—
30
1
—
30
3
—
1 ⁄4
60
2
—
60
1
—
2 ⁄2
100
3
—
100
1
—
3 ⁄2
200
4
—
200
Catalog Number List Price $
17CP92B*81
17DP92B*81
17EP92B*81
17FP92B*81
17GP92B*81
17HP92B*81
17IP92B*81
17JP92B*81
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog Number
17CP92W*81
17DP92W*81
17EP92W*81
17FP92W*81
17GP92W*81
17HP92W*81
17IP92W*81
17JP92W*81
Catalog Number
17CP92F*81
17DP92F*81
17EP92F*81
17FP92F*81
17GP92F*81
17HP92F*81
17IP92F*81
17JP92F*81
List Price $
NEMA 12, NEMA 3/3R,
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight
List Price $ Catalog Number List Price $
17CP92N*81
17DP92N*81
17EP92N*81
17FP92N*81
17GP92N*81
17HP92N*81
17IP92N*81
17JP92N*81
Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
NEMA 1
NEMA 4/4X Stainless
General Purpose
200
Volts
3
71⁄2
10
10
15
25
230
Volts
3
71⁄2
10
15
20
30
460
Volts
5
10
15
25
30
50
Contactor
575
Amp
Volts Rating
5
18
10
27
15
40
25
45
30
60
50
90
Disc
NEMA Half Amp
Size
Size Rating
0
—
30
1
—
30
3
—
1 ⁄4
60
2
—
60
1
—
2 ⁄2
100
3
—
100
NEMA 12, NEMA 3/3R,
NEMA 4 Painted
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (optional)
Catalog Number
17CP82B*81
17DP82B*81
17EP82B*81
17FP82B*81
17GP82B*81
17HP82B*81
List Price $
Catalog Number
17CP82W*81
17DP82W*81
17EP82W*81
17FP82W*81
17GP82W*81
17HP82W*81
Industrial Use
Weatherproof
Watertight, Dust-tight
List Price $
Catalog Number
17CP82N*81
17DP82N*81
17EP82N*81
17FP82N*81
17GP82N*81
17HP82N*81
List Price $
Standard Width Enclosure, Single Phase, (Catalog Numbers are three phase, wire for single phase in the field)
Max Hp
Enclosure
NEMA 1
General Purpose
115
Volts
1
2
3
3
5
208/ Contactor
Disc
230
Amp
NEMA Half Amp
Volts Rating
Size
Size Rating
2
18
0
—
30
3
27
1
—
30
5
35
1P
—
60
71⁄2
45
2
—
60
10
60
—
21⁄2 100
Catalog Number List Price $
17CP92B*81
17DP92B*81
17EP92B*81
17FP92B*81
17GP92B*81
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.
8/20
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog Number
17CP92W*81
17DP92W*81
17EP92W*81
17FP92W*81
17GP92W*81
List Price $ Catalog Number
17CP92F*81
17DP92F*81
17EP92F*81
17FP92F*81
17GP92F*81
Dual voltage coils not available in modified starters.
For conduit hubs and conversion instructions, see page
8/88.
Product Category: NEMA
For
For
For
NEMA 12, NEMA 3/3R,
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight
List Price $ Catalog Number
17CP92N*81
17DP92N*81
17EP92N*81
17FP92N*81
17GP92N*81
List Price $
60A disc, order fusible cat. no. page 8/23.
200A disc, order fusible cat. no. page 8/23.
316 Stainless Steel option see page 8/98.
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Heavy Duty Starters
Fusible with Solid State Overload, Class 17
Selection
Coil Table
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
NEMA 1
Overload
NEMA 4/4X Stainless NEMA 4X Fiberglass
General Purpose
200
Volts
1
⁄6
—
1
⁄2
—
2
—
3
—
1
⁄6
—
1
⁄2
—
2
—
3
—
71⁄2
—
10
10
—
—
—
15
20
—
25
30
—
40
—
75
—
—
—
—
150
—
—
—
—
230
Volts
1
⁄6
—
3
⁄4
—
2
—
3
—
1
⁄6
—
3
⁄4
—
2
—
3
—
71⁄2
—
10
15
—
—
—
20
25
—
30
40
—
50
—
100
100
—
—
—
200
—
—
—
—
460
Volts
—
1
⁄3
—
11⁄2
—
5
—
10
—
1
⁄3
—
11⁄2
—
5
—
10
—
15
—
—
25
—
30
—
—
50
—
—
75
—
100
—
—
—
200
200
—
400
400
600
900
575
Volts
—
1
⁄2
—
2
—
5
—
10
—
1
⁄2
—
2
—
5
—
10
—
15
—
—
25
30
—
—
—
50
—
—
75
—
100
—
—
125
200
—
—
400
400
600
900
NEMA
Size
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
—
—
2
2
—
—
—
3
3
3
—
—
4
4
5
5
5
5
5
6
6
6
7
8
Half
Size
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
21⁄2
—
—
—
31⁄2
31⁄2
—
—
—
—
—
—
—
—
—
—
—
—
Amp
Range
0.25–1
0.25–1
0.75–3.4
0.75–3.4
3–12
3–12
5.5–22
5.5–22
0.25–1
0.25–1
0.75–3.4
0.75–3.4
3–12
3–12
5.5–22
5.5–22
10–40
10–40
10–40
13–52
13–52
13–52
13–52
25–100
25–100
25–100
25–100
50–200
50–200
50–200
50–200
55–250
55–250
55–250
55–250
55–250
160–630
160–630
160–630
400–1220
400–1220
Frame
Size
A
A
A
A
A1
A1
A1
A1
A
A
A
A
A1
A1
A1
A1
A1
A1
A1
B
B
B
B
B
B
B
B
B
B
B
B
—
—
—
—
—
—
—
—
A1+CT
A1+CT
Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
Dual
voltage coils not available in modified starters or
in starter sizes 5–8.
conduit hubs and conversion instructions, see
page 8/88.
For
Siemens Industry, Inc.
Industrial Controls Catalog
Disc.
Amp
Range
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
60
60
60
60
60
60
100
100
100
100
200
200
200
200
200
400
600
400
400
600
600
600
800
1200
1600
Fuse Clip
Amp/Volts
30A/250V
30A/600V
30A/250V
30A/600V
30A/250V
30A/600V
30A/250V
30A/600V
30A/250V
30A/600V
30A/250V
30A/600V
30A/250V
30A/600V
30A/250V
30A/600V
60A/250V
60A/600V
60A/250V
60A/250V
60A/600V
60A/600V
100A/600V
100A/250V
100A/250V
100A/600V
200A/250V
200A/250V
200A/600V
200A/250V
200A/600V
400A/250V
600A/250V
200A/600V
400A/600V
600A/600V
600A/250V
600A/600V
800A/600V
1200A/600V
1600A/600V
Watertight, Dust-tight,
Watertight, Dust-tight
Corrosion Resistant
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Catalog
List
Catalog
List
Number
Price $ Number
Price $
17CUA92B*10
17CUA92W*10
17CUA92B*11
17CUA92W*11
17CUB92B*10
17CUB92W*10
17CUB92B*11
17CUB92W*11
17CUC92B*10
17CUC92W*10
17CUC92B*11
17CUC92W*11
17CUD92B*10
17CUD92W*10
17CUD92B*11
17CUD92W*11
17DUA92B*10
17DUA92W*10
17DUA92B*11
17DUA92W*11
17DUB92B*10
17DUB92W*10
17DUB92B*11
17DUB92W*11
17DUC92B*10
17DUC92W*10
17DUC92B*11
17DUC92W*11
17DUD92B*10
17DUD92W*10
17DUD92B*11
17DUD92W*11
17DUE92B*12
17DUE92W*12
17EUE92B*13
17EUE92W*13
17EUE92B*12
17EUE92W*12
17FUF92B*12
17FUF92W*12
17FUF92B*13
17FUF92W*13
17GUF92B*13
17GUF92W*13
17GUF92B*15
17GUF92W*15
17GUG92B*14
17GUG92W*14
17HUG92B*14
17HUG92W*14
17HUG92B*15
17HUG92W*15
17HUG92B*16
17HUG92W*16
17IUH92B*16
17IUH92W*16
17IUH92B*17
17IUH92W*17
17JUH92B*16
17JUH92W*16
17JUH92B*17
17JUH92W*17
17LPU92B*18
17LPU92E*18
17LPU92B*20
17LPU92E*20
17LPU92B*17
17LPU92E*17
17LPU92B*19
17LPU92E*19
17LPU92B*21
17LPU92E*21
17MPX92B*20
17MPX92E*20
17MPX92B*21
17MPX92E*21
17MPX92B*23
17MPX92E*23
17NUN92B*23
—
—
17PUN92B*25
—
—
Use Class J fuses only.
Enclosure is NEMA Type 4 (painted
Single phase wiring page 8/131.
F coil 100-250V AC 50/60Hz, or DC,
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
Catalog
List
Catalog
List
Number
Price $ Number
Price $
17CUA92F*10
17CUA92N*10
17CUA92F*11
17CUA92N*11
17CUB92F*10
17CUB92N*10
17CUB92F*11
17CUB92N*11
17CUC92F*10
17CUC92N*10
17CUC92F*11
17CUC92N*11
17CUD92F*10
17CUD92N*10
17CUD92F*11
17CUD92N*11
17DUA92F*10
17DUA92N*10
17DUA92F*11
17DUA92N*11
17DUB92F*10
17DUB92N*10
17DUB92F*11
17DUB92N*11
17DUC92F*10
17DUC92N*10
17DUC92F*11
17DUC92N*11
17DUD92F*10
17DUD92N*10
17DUD92F*11
17DUD92N*11
17DUE92F*12
17DUE92N*12
17EUE92F*13
17EUE92N*13
17EUE92F*12
17EUE92N*12
17FUF92F*12
17FUF92N*12
17FUF92F*13
17FUF92N*13
17GUF92F*13
17GUF92N*13
17GUF92F*15
17GUF92N*15
17GUG92F*14
17GUG92N*14
17HUG92F*14
17HUG92N*14
17HUG92F*15
17HUG92N*15
17HUG92F*16
17HUG92N*16
17IUH92F*16
17IUH92N*16
17IUH92F*17
17IUH92N*17
17JUH92F*16
17JUH92N*16
17JUH92F*17
17JUH92N*17
—
—
17LPU92N*18
—
—
17LPU92N*20
—
—
17LPU92N*17
—
—
17LPU92N*19
—
—
17LPU92N*21
—
—
17MPX92N*20
—
—
17MPX92N*21
—
—
17MPX92N*23
—
—
17NUN92N*23
—
—
17PUN92N*25
Only
steel).
H coil 150-500V AC 50/60Hz, or DC
Product Category: NEMA
available
F coil 100-250V AC 50/60Hz, or DC
Steel option see page 8/98.
with the ESP200 OLR will not be available until approximately December 2009. Continue to
order enclosed starters with the ESP100 OLR until then.
For 316 Stainless
Enclosed starters
8/21
Combination Heavy Duty Starters
Fusible with Solid State Overload, Class 17
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp
200
Volts
⁄6
Enclosure
Overload
NEMA 1
NEMA 4/4X Stainless
General Purpose
Watertight, Dust-tight,
304 Stainless Steel
316 Stainless Steel (Optional)
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
230
Volts
460
Volts
575
Volts
NEMA Half
Size
Size
Amp
Range
Frame
Size
Disc.
Amp
Range
Fuse Clip
Amp/Volts
Catalog
Number
⁄6
—
1
⁄3
—
1
⁄2
0
—
0.25–1
A
30
30A/250V
17CUA82B*10
17CUA82W*10
17CUA82N*10
0
—
0.25–1
A
30
30A/600V
17CUA82B*11
17CUA82W*11
17CUA82N*11
—
11⁄2
—
2
0
—
0.75–3.4
A
30
30A/250V
17CUB82B*10
17CUB82W*10
17CUB82N*10
0
—
0.75–3.4
A
30
30A/600V
17CUB82B*11
17CUB82W*11
17CUB82N*11
—
5
—
5
0
—
3–12
A1
30
30A/250V
17CUC82B*10
17CUC82W*10
17CUC82N*10
0
—
3–12
A1
30
30A/600V
17CUC82B*11
17CUC82W*11
17CUC82N*11
—
10
—
10
0
—
5.5–22
A1
30
30A/250V
17CUD82B*10
17CUD82W*10
17CUD82N*10
—
5.5–22
A1
30
30A/600V
17CUD82B*11
17CUD82W*11
17CUD82N*11
—
1
⁄3
—
1
⁄2
0
1
—
0.25–1
A
30
30A/250V
17DUA82B*10
17DUA82W*10
17DUA82N*10
—
0.25–1
A
30
30A/600V
17DUA82B*11
17DUA82W*11
17DUA82N*11
—
11⁄2
—
2
1
1
—
0.75–3.4
A
30
30A/250V
17DUB82B*10
17DUB82W*10
17DUB82N*10
—
0.75–3.4
A
30
30A/600V
17DUB82B*11
17DUB82W*11
17DUB82N*11
—
5
—
5
1
1
—
3–12
A1
30
30A/250V
17DUC82B*10
17DUC82W*10
17DUC82N*10
1
—
3–12
A1
30
30A/600V
17DUC82B*11
17DUC82W*11
17DUC82N*11
A1
30
30A/250V
17DUD82B*10
17DUD82W*10
17DUD82N*10
1
1
—
1
⁄2
—
3
⁄4
—
2
—
2
—
3
—
3
—
1
⁄6
—
1
⁄6
—
1
⁄2
—
3
⁄4
—
2
—
2
—
3
—
3
—
71⁄2
—
71⁄2
—
10
—
10
10
15
—
—
—
—
—
List
Price $
Catalog
Number
List
Price $
Catalog
Number
—
10
—
10
1
—
5.5–22
1
—
5.5–22
A1
30
30A/600V
17DUD82B*11
17DUD82W*11
17DUD82N*11
—
15
—
15
1
—
13⁄4
10–40
A1
60
60A/250V
17DUE82B*12
17DUE82W*12
17DUE82N*12
10–40
A1
60
60A/600V
17EUE82B*13
17EUE82W*13
17EUE82N*13
—
—
—
2
13⁄4
10–40
A1
60
60A/250V
17EUE82B*12
17EUE82W*12
17EUE82N*12
—
13–52
B
60
60A/250V
17FUF82B*12
17FUF82W*12
17FUF82N*12
2
13–52
B
60
60A/600V
17FUF82B*13
17FUF82W*13
17FUF82N*13
13–52
B
60
60A/600V
17GUF82B*13
17GUF82W*13
17GUF82N*13
—
—
25
—
25
30
—
—
—
30
—
21⁄2
—
—
21⁄2
13–52
B
100
100A/600V
17GUF82B*15
17GUF82W*15
17GUF82N*15
15
20
—
—
21⁄2
25–100
B
100
100A/250V
17GUG82B*14
17GUG82W*14
17GUG82N*14
20
25
—
50
—
3
—
25–100
B
100
100A/250V
17HUG82B*14
17HUG82W*14
17HUG82N*14
3
—
25–100
B
100
100A/600V
17HUG82B*15
17HUG82W*15
17HUG82N*15
—
3
—
25–100
B
200
200A/250V
17HUG82B*16
17HUG82W*16
17HUG82N*16
—
—
—
50
25
30
—
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
Dual
voltage coils not available in modified starters.
8/22
For
conduit hubs and conversion instructions, see
page 8/88.
316 Stainless Steel option see page 8/98.
For
Product Category: NEMA
List
Price $
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Heavy Duty Starters
Fusible with Ambient Compensated Bimetal Overload, Class 17
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. (3 required)
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
200
Volts
3
—
5
—
7 1⁄2
10
—
10
—
—
—
15
20
—
25
30
—
40
—
Enclosure
230
Volts
3
—
5
—
7 1⁄2
10
—
15
—
—
—
20
25
—
30
40
—
50
—
Contactor
460
575 Amp
Volts Volts Rating
—
—
18
5
5
18
—
—
27
10
10
27
—
—
27
—
—
40
15
15
40
—
—
45
25
25
45
—
30
60
30
—
60
—
—
60
—
—
90
50
50
90
—
—
90
—
—
115
75
75
115
—
—
135
100
100
135
NEMA
Size
0
0
1
1
1
—
—
2
2
—
—
—
3
3
3
—
—
4
4
Half
Size
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
21⁄2
—
—
—
31⁄2
31⁄2
—
—
Disc
Amp
Rating
30
30
30
30
60
60
60
60
60
60
100
100
100
100
200
200
200
200
200
Fuse Clip
Size
Amps/Volts
30A/250V
30A/600V
30A/250V
30A/600V
60A/250V
60A/250V
60A/600V
60A/250V
60A/600V
60A/600V
100A/600V
100A/250V
100A/250V
100A/600V
200A/250V
200A/250V
200A/600V
200A/250V
200A/600V
NEMA 1
NEMA 4/4X Stainless
NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog
List
Number
Price $
17CP92W*1081
17CP92W*1181
17DP92W*1081
17DP92W*1181
17DP92W*1281
17EP92W*1281
17EP92W*1381
17FP92W*1281
17FP92W*1381
17GP92W*1381
17GP92W*1581
17GP92W*1481
17HP92W*1481
17HP92W*1581
17HP92W*1681
17IP92W*1681
17IP92W*1781
17JP92W*1681
17JP92W*1781
Catalog
List
Number
Price $
17CP92F*1081
17CP92F*1181
17DP92F*1081
17DP92F*1181
17DP92F*1281
17EP92F*1281
17EP92F*1381
17FP92F*1281
17FP92F*1381
17GP92F*1381
17GP92F*1581
17GP92F*1481
17HP92F*1481
17HP92F*1581
17HP92F*1681
17IP92F*1681
17IP92F*1781
17JP92F*1681
17JP92F*1781
Catalog
List
Number
Price $
17CP92B*1081
17CP92B*1181
17DP92B*1081
17DP92B*1181
17DP92B*1281
17EP92B*1281
17EP92B*1381
17FP92B*1281
17FP92B*1381
17GP92B*1381
17GP92B*1581
17GP92B*1481
17HP92B*1481
17HP92B*1581
17HP92B*1681
17IP92B*1681
17IP92B*1781
17JP92B*1681
17JP92B*1781
NEMA 12, NEMA 3/3R,
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight
Catalog
Number
17CP92N*1081
17CP92N*1181
17DP92N*1081
17DP92N*1181
17DP92N*1281
17EP92N*1281
17EP92N*1381
17FP92N*1281
17FP92N*1381
17GP92N*1381
17GP92N*1581
17GP92N*1481
17HP92N*1481
17HP92N*1581
17HP92N*1681
17IP92N*1681
17IP92N*1781
17JP92N*1681
17JP92N*1781
List
Price $
Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp
200
Volts
3
—
5
—
7 1⁄2
10
—
10
—
—
—
15
20
—
25
Enclosure
230
Volts
3
—
5
—
7 1⁄2
10
—
15
—
—
—
20
25
—
30
460
Volts
—
5
—
10
—
—
15
—
25
—
30
—
—
50
—
575
Volts
—
5
—
10
—
—
15
—
25
30
—
—
—
50
—
Contactor
Amp
Rating
18
18
27
27
27
40
40
45
45
60
60
60
90
90
90
NEMA
Size
0
0
1
1
1
—
—
2
2
—
—
—
3
3
3
Half
Size
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
21⁄2
—
—
—
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.
Siemens Industry, Inc.
Industrial Controls Catalog
Disc
Amp
Rating
30
30
30
30
60
60
60
60
60
60
100
100
100
100
200
Fuse Clip
Size
Amps/Volts
30A/250V
30A/600V
30A/250V
30A/600V
60A/250V
60A/250V
60A/600V
60A/250V
60A/600V
60A/600V
100A/600V
100A/250V
100A/250V
100A/600V
200A/250V
NEMA 1
NEMA 4/4X Stainless
General Purpose
Watertight, Dust-tight
Industrial Use Weatherproof
304 Stainless Steel
316 Stainless Steel (optional)
Industrial Use
Weatherproof
Watertight, Dust-tight
Catalog Number
17CP82W*1081
17CP82W*1181
17DP82W*1081
17DP82W*1181
17DP82W*1281
17EP82W*1281
17EP82W*1381
17FP82W*1281
17FP82W*1381
17GP82W*1381
17GP82W*1581
17GP82W*1481
17HP82W*1481
17HP82W*1581
17HP92W*1681
Catalog Number
17CP82N*1081
17CP82N*1181
17DP82N*1081
17DP82N*1181
17DP82N*1281
17EP82N*1281
17EP82N*1381
17FP82N*1281
17FP82N*1381
17GP82N*1381
17GP82N*1581
17GP82N*1481
17HP82N*1481
17HP82N*1581
17HP92N*1681
Catalog Number
17CP82B*1081
17CP82B*1181
17DP82B*1081
17DP82B*1181
17DP82B*1281
17EP82B*1281
17EP82B*1381
17FP82B*1281
17FP82B*1381
17GP82B*1381
17GP82B*1581
17GP82B*1481
17HP82B*1481
17HP82B*1581
17HP92B*1681
List Price $
Dual voltage coils not available in modified starters.
For conduit hubs and conversion instructions, see page
List Price $
NEMA 12, NEMA 3/3R,
NEMA 4 Painted
Single phase wiring page 8/131.
For 316 Stainless Steel option see
List Price $
page 8/98.
8/88.
Product Category: NEMA
8/23
Combination Heavy Duty Starters
MCP Type with Solid State Overload, Class 18
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
Motor Circuit
200 230 460 575 NEMA Half Interruter ETI Amp
Volts Volts Volts Volts Size Size Amps
Range
Frame Catalog
Size Number
List
Price $
NEMA 4/4X Stainless NEMA 4X
Watertight, Dust-tight,
Fiberglass
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Corrosion Resistant
Watertight, Dust-tight
304 Stainless Steel
Corrosion Resistant
316 Stainless Steel (Optional)
Div. 1 and Div. 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
Catalog
Number
List
Price $
Catalog
Number
List
Catalog
Price $ Number
List
Price $
Catalog
Number
1
⁄2
1
⁄2
1
1
0
—
3
0.75–3.4
A
18CUB92B*
18CUB92W*
18CUB92F*
18CUB92H*
18CUB92N*
2
2
5
5
0
—
10
3–12
A1
18CUC92B*
18CUC92W*
18CUC92F*
18CUC92H*
18CUC92N*
3
3
—
25
5.5–22
A1
18CUD92B*
18CUD92W*
18CUD92F*
18CUD92H*
18CUD92N*
⁄2
1
⁄2
—
1
0
1
—
1
1
—
3
0.75–3.4
A
18DUB92B*
18DUB92W*
18DUB92F*
18DUB92H*
18DUB92N*
2
2
5
5
1
—
10
3–12
A1
18DUC92B*
18DUC92W*
18DUC92F*
18DUC92H*
18DUC92N*
3
3
7 1⁄2
10
1
—
25
5.5–22
A1
18DUD92B*
18DUD92W*
18DUD92F*
18DUD92H*
18DUD92N*
7 1⁄2
7 1⁄2
10
1
10–40
A1
18DUE92B*
18DUE92W*
18DUE92F*
18DUE92H*
18DUE92N*
—
15
15
—
13⁄4
30
—
10
—
15
40
10–40
A1
18EUE92B*
18EUE92W*
18EUE92F*
18EUE92H*
18EUE92N*
25
25
50
13–52
B
18FUF92B*
18FUF92W*
18FUF92F*
18FUF92H*
18FUF92N*
15
20
30
30
—
2 1⁄2
100
25–100
B
18GUG92B*
18GUG92W*
18GUG92F*
18GUG92H*
18GUG92N*
25
30
50
50
100
25–100
B
18HUG92B*
18HUG92W*
18HUG92F*
18HUG92H*
18HUG92N*
30
40
75
75
125
50–200
B
18IUH92B*
18IUH92W*
18IUH92F*
18IUH92H*
18IUH92N*
40
50
100
100
—
4
—
3 1⁄2
—
150
50–200
B
18JUH92B*
18JUH92W*
18JUH92F*
18JUH92H*
18JUH92N*
50
75
150
200
5
—
250
55–250
—
18LPT92B*
18LPT92E*
—
—
18LPT92H*
18LPT92N*
75
100
200
5
—
400
55–250
—
18LPU92B*
18LPU92E*
—
—
18LPU92H*
100
125
250
—
300
6
—
400
160–630
—
18MPW92B*
18MPW92E*
—
—
—
—
18MPW92N*
150
200
400
400
6
—
600
160–630
—
18MPX92B*
18MPX92E*
—
—
—
—
18MPX92N*
—
250
500
500
7
—
800
400–1220 A1+CT 18NUV92B*
—
—
—
—
—
—
18NUV92N*
—
300
600
600
7
—
1000
400–1220 A1+CT 18NUY92B*
—
—
—
—
—
—
18NUY92N*
—
400
800
800
8
—
1200
400–1220 A1+CT 18PUW92B*
—
—
—
—
—
—
18PUW92N*
—
450
900
900
8
—
1600
400–1220 A1+CT 18PUZ92B*
—
—
—
—
—
—
18PUZ92N*
—
2
—
3
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
For
Only
Dual
Enclosure is NEMA Type 4 (painted
F coil 100-250V AC 50/60Hz, or DC,
For 316 Stainless
Enclosed starters
voltage coils not available in modified starters or
in starter sizes 5–8.
8/24
conduit hubs and conversion instructions, see
page 8/88.
steel).
H coil 150-500V AC 50/60Hz, or DC
Product Category: NEMA
List
Price $
18LPU92N*
available
F coil 100-250V AC 50/60Hz, or DC
Steel option see page 8/98.
with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Heavy Duty Starters
MCP Type with Solid State Overload, Class 18
Selection
Ordering Information
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.
䊳
䊳
䊳
䊳
䊳
䊳
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
NEMA 1
Overload
NEMA 4/4X Stainless
200
Volts
230
Volts
460
Volts
575
Volts
NEMA
Size
Half
Size
Motor
Circuit
Interruter
ETI Amps
Amp
Range
Frame
Size
Catalog
Number
NEMA 12
Watertight, Dust-tight, Corrosion Resistant NEMA 3/3R
304 Stainless Steel
Industrial Use
316 Stainless Steel (Optional)
Weatherproof
(Field Convertible to 3/3R)
General Purpose
List
Price $
Catalog
Number
List
Price $
Catalog
Number
1
⁄2
1
⁄2
1
1
0
—
3
0.75–3.4
A
18CUB82B*
18CUB82W*
18CUB82N*
2
2
5
5
0
—
10
3–12
A1
18CUC82B*
18CUC82W*
18CUC82N*
3
3
—
—
0
—
25
5.5–22
A1
18CUD82B*
18CUD82W*
18CUD82N*
1
⁄2
1
⁄2
1
1
1
—
3
0.75–3.4
A
18DUB82B*
18DUB82W*
18DUB82N*
2
2
5
5
1
—
10
3–12
A1
18DUC82B*
18DUC82W*
18DUC82N*
3
3
71⁄2
10
1
—
25
5.5–22
A1
18DUD82B*
18DUD82W*
18DUD82N*
71⁄2
71⁄2
10
—
1
—
30
10–40
A1
18DUE82B*
18DUE82W*
18DUE82N*
—
—
15
15
—
13⁄4
40
10–40
A1
18EUE82B*
18EUE82W*
18EUE82N*
10
15
25
25
2
—
50
13–52
B
18FUF82B*
18FUF82W*
18FUF82N*
15
20
30
30
—
21⁄2
100
25–100
B
18GUG82B*
18GUG82W*
18GUG82N*
25
30
50
50
3
—
100
25–100
B
18HUG82B*
18HUG82W*
18HUG82N*
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
Dual
voltage coils not available in modified starters.
Siemens Industry, Inc.
Industrial Controls Catalog
For
conduit hubs and conversion instructions, see
page 8/88.
316 Stainless Steel option see page 8/98.
For
Product Category: NEMA
List
Price $
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
8/25
Combination Heavy Duty Starters
MCP Type with Ambient Compensated Bimetal Overload, Class 18
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. (3 required)
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/118.
Wiring Diagrams see page 8/132.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
Contactor
200 230 460 575 Amp NEMA Half
Volts Volts Volts Volts Rating Size Size
1
⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
10
10
15
—
25
30
40
1
⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
15
15
20
—
30
40
50
1
3
5
1
3
7 1⁄2
10
15
—
20
25
30
—
30
50
75
100
1
3
5
1
3
7 1⁄2
10
15
—
20
25
30
—
30
50
75
100
18
18
18
27
27
27
27
40
40
45
45
60
60
90
90
115
135
0
0
0
1
1
1
1
—
—
2
2
—
—
3
3
—
4
—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
—
—
31⁄2
—
Motor
Circuit
Interrupter
ETI Amps
3
10
25
3
10
25
30
40
50
40
50
50
100
50
100
125
150
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel
Corrosion Resistant
(optional)
Catalog
Number
List
Catalog
Price $ Number
18CP92BA*81
18CP92BB*81
18CP92BC*81
18DP92BA*81
18DP92BB*81
18DP92BD*81
18DP92BE*81
18EP92BF*81
18EP92BG*81
18FP92BH*81
18FP92BJ*81
18GP92BK*81
18GP92BL*81
18HP92BM*81
18HP92BN*81
18IP92BP*81
18JP92BR*81
List
Catalog
Price $ Number
18CP92WA*81
18CP92WB*81
18CP92WC*81
18DP92WA*81
18DP92WB*81
18DP92WD*81
18DP92WE*81
18EP92WF*81
18EP92WG*81
18FP92WH*81
18FP92WJ*81
18GP92WK*81
18GP92WL*81
18HP92WM*81
18HP92WN*81
18IP92WP*81
18JP92WR*81
NEMA 7 & 9
NEMA 3 & 4
NEMA 12,NEMA 3/3R,
NEMA 4 Painted
Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Industrial Use
Weatherproof
List
Catalog
Price $ Number
18CP92FA*81
18CP92FB*81
18CP92FC*81
18DP92FA*81
18DP92FB*81
18DP92FD*81
18DP92FE*81
18EP92FF*81
18EP92FG*81
18FP92FH*81
18FP92FJ*81
18GP92FK*81
18GP92FL*81
18HP92FM*81
18HP92FN*81
18IP92FP*81
18JP92FR*81
List
Price $
18CP92HA*81
18CP92HB*81
18CP92HC*81
18DP92HA*81
18DP92HB*81
18DP92HD*81
18DP92HE*81
18EP92HF*81
18EP92HG*81
18FP92HH*81
18FP92HJ*81
18GP92HK*81
18GP92HL*81
18HP92HM*81
18HP92HN*81
18IP92HP*81
18JP92HR*81
Watertight, Dust-tight
Catalog
Number
List
Price $
18CP92NA*81
18CP92NB*81
18CP92NC*81
18DP92NA*81
18DP92NB*81
18DP92ND*81
18DP92NE*81
18EP92NF*81
18EP92NG*81
18FP92NH*81
18FP92NJ*81
18GP92NK*81
18GP92NL*81
18HP92NM*81
18HP92NN*81
18IP92NP*81
18JP92NR*81
Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
NEMA 1
200
Volts
1
⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
10
10
15
—
25
230
Volts
1
⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
15
15
20
—
30
460
Volts
1
3
5
1
3
7 1⁄2
10
15
—
20
25
30
—
30
50
575
Volts
1
3
5
1
3
7 1⁄2
10
15
—
20
25
30
—
30
50
Contactor
Amp
Rating
NEMA
Size
18
18
18
27
27
27
27
40
40
45
45
60
60
90
90
0
0
0
1
1
1
1
—
—
2
2
—
—
3
3
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.
8/26
Half
Size
Motor Circuit
Interrupter ETI Amps
—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
—
—
3
10
25
3
10
25
30
40
50
40
50
50
100
50
100
Catalog
Number
NEMA 4/4X Stainless
NEMA 12, NEMA 3/3R,
Catalog
Number
Catalog
Number
Watertight, Dust-tight
NEMA 4 Painted
Corrosion Resistant
Industrial Use
304 Stainless Steel
Weatherproof
316 Stainless Steel (optional) Watertight, Dust-tight
General Purpose
List
Price $
18CP82BA*81
18CP82BB*81
18CP82BC*81
18DP82BA*81
18DP82BB*81
18DP82BD*81
18DP82BE*81
18EP82BF*81
18EP82BG*81
18FP82BH*81
18FP82BJ*81
18GP82BK*81
18GP82BL*81
18HP82BM*81
18HP82BN*81
Dual voltage coils not available in modified starters.
For conduit hubs and conversion instructions, see
List
Price $
18CP82WA*81
18CP82WB*81
18CP82WC*81
18DP82WA*81
18DP82WB*81
18DP82WD*81
18DP82WE*81
18EP82WF*81
18EP82WG*81
18FP82WH*81
18FP82WJ*81
18GP82WK*81
18GP82WL*81
18HP82WM*81
18HP82WN*81
For
List
Price $
18CP82NA*81
18CP82NB*81
18CP82NC*81
18DP82NA*81
18DP82NB*81
18DP82ND*81
18DP82NE*81
18EP82NF*81
18EP82NG*81
18FP82NH*81
18FP82NJ*81
18GP82NK*81
18GP82NL*81
18HP82NM*81
18HP82NN*81
316 Stainless Steel option see page 8/98.
page 8/88.
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Reversing Heavy Duty Starters
Solid State Overload, Class 22
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/105 open and 8/121 enclosed.
Wiring Diagrams see page 8/134.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
Open Type
Overload
NEMA 1
Standard Auxiliary
Contacts
200 230 460 575 NEMA Half Amp
Volts Volts Volts Volts Size Size Range
Frame Catalog
Size Number
General Purpose
List
Catalog
Price $ Number
NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight,
Watertight, Dust-tight
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel
(Optional)
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Catalog
Price $ Number
Corrosion Resistant
List
Catalog
Price $ Number
Div. 1 and Div. 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
List
Catalog
Price $ Number
List
Catalog
Price $ Number
List
Price $
⁄6
1
⁄6
1
⁄3
1
⁄2
00
—
0.25–1
A
22BUA32A*
22BUA32B*
Use Size 0
—
Use Size 0
—
Use Size 0
—
Use Size 0
—
1
⁄2
3
⁄4
11⁄2
2
00
—
0.75–3.4 A
22BUB32A*
22BUB32B*
Use Size 0
—
Use Size 0
—
Use Size 0
—
Use Size 0
—
11⁄2
11⁄2
2
—
00
—
3–12
A1
22BUC32A*
22BUC32B*
Use Size 0
—
Use Size 0
—
Use Size 0
—
Use Size 0
—
⁄6
1
⁄3
1⁄2
0
—
0.25–1
A
22CUA32A*
22CUA32B*
22CUA32W*
22CUA32F*
22CUA32H*
22CUA320*
1
⁄6
1
1
⁄2
3
⁄4
11⁄2
2
0
—
0.75–3.4 A
22CUB32A*
22CUB32B*
22CUB32W*
22CUB32F*
22CUB32H*
22CUB320*
2
2
5
5
0
—
3–12
A1
22CUC32A*
22CUC32B*
22CUC32W*
22CUC32F*
22CUC32H*
22CUC320*
3
3
—
—
0
—
5.5–22
A1
22CUD32A*
22CUD32B*
22CUD32W*
22CUD32F*
22CUD32H*
22CUD320*
⁄6
1
1
⁄2
1
⁄6
1
⁄3
1
⁄2
1
—
0.25–1
A
22DUA32A*
22DUA32B*
22DUA32W*
22DUA32F*
22DUA32H*
22DUA320*
3
⁄4
11⁄2
2
1
—
0.75–3.4 A
22DUB32A*
22DUB32B*
22DUB32W*
22DUB32F*
22DUB32H*
22DUB320*
2
2
5
5
1
—
3–12
A1
22DUC32A*
22DUC32B*
22DUC32W*
22DUC32F*
22DUC32H*
22DUC320*
3
3
10
10
1
—
5.5–22
A1
22DUD32A*
22DUD32B*
22DUD32W*
22DUD32F*
22DUD32H*
22DUD320*
71⁄2
71⁄2
—
—
1
—
10–40
A1
22DUE32A*
22DUE32B*
22DUE32W*
22DUE32F*
22DUE32H*
22DUE320*
10
10
15
15
—
13⁄4
10–40
A1
22EUE32A*
22EUE32B*
22EUE32W*
22EUE32F*
22EUE32H*
22EUE320*
10
15
25
25
2
—
13–52
B
22FUF32A*
22FUF32B*
22FUF32W*
22FUF32F*
22FUF32H*
22FUF320*
15
20
30
30
—
21⁄2
25–100
B
22GUG32A*
22GUG32B*
22GUG32W*
22GUG32F*
22GUG32H*
22GUG320*
25
30
50
50
3
—
25–100
B
22HUG32A*
22HUG32B*
22HUG32W*
22HUG32F*
22HUG32H*
22HUG320*
30
40
75
75
—
31⁄2
50–200
B
22IUH32A*
22IUH32B*
22IUH32W*
22IUH32F*
22IUH32H*
22IUH320*
40
50
100
100
4
—
50–200
B
22JUH32A*
22JUH32B*
22JUH32W*
22JUH32F*
22JUH32H*
75
100
200
200
5
—
55–250
—
22LPU32A*
22LPU32B*
22LPU32E*
—
—
—
—
22LPU320*
150
200
400
400
6
—
160–630 —
22MPX32A*
22MPX32B*
22MPX32E*
—
—
—
—
22MPX320*
—
300
600
600
7
—
400–1220 A1+CT 22NUN32A*
22NUN32B*
—
—
—
—
—
—
22NUN320*
—
450
900
900
8
—
400–1220 A1+CT 22PUN32A*
22PUN32B*
—
—
—
—
—
—
22PUN320*
1
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
Dual voltage coils not available in size 5–8 starters.
For conduit hubs and conversion instructions, see
page 8/88.
Siemens Industry, Inc.
Industrial Controls Catalog
Enclosure is rated
Only available
only NEMA 4 (painted steel).
F coil 100-250V AC 50/60Hz, or DC
H coil 150-500V AC 50/60Hz, or DC
Only available
F coil 100-250V AC 50/60Hz, or DC
Product Category: NEMA
22JUH320*
Auxiliary
contacts
22B-22E 4th pole built-in
22F-22J 2 NO & 2 NC
Enclosed starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
8/27
Reversing Heavy Duty Starters
Ambient Compensated Bimetal Overload with Manual and Auto Reset, Class 22
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. Single phase starters require 1 heater
element. 3-phase starters require 3 heater elements.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/105 open and 8/121 enclosed.
Wiring Diagrams see page 8/133.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
Open Type
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight, Dust-tight
Corrosion Resistant
Indoor/Outdoor Use
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Div 1 and Div 2
Class I Groups C & D
Industrial Use
Weatherproof
Class II Groups E, F & G
Class III
Contactor
200 230 460 575 Amp NEMA Half Catalog
Volts Volts Volts Volts Rating Size Size Number
1 1⁄2
3
7 1⁄2
10
10
15
25
30
40
1 1⁄2
3
7 1⁄2
10
15
20
30
40
50
2
2
5
5
10 10
15 15
25 25
30 30
50 50
75 75
100 100
9
18
27
40
45
60
90
115
135
00
0
1
—
2
—
3
—
4
—
—
—
1 3⁄4
—
2 1⁄2
—
3 1⁄2
—
Bolted Enclosures
List
Catalog
Price $ Number
22BP32A*81
22CP32A*81
22DP32A*81
22EP32A*81
22FP32A*81
22GP32A*81
22HP32A*81
22IP32A*81
22JG32A*81
List
Catalog
Price $ Number
22BP32B*81
22CP32B*81
22DP32B*81
22EP32B*81
22FP32B*81
22GP32B*81
22HP32B*81
22IP32B*81
22JG32B*81
List
Price $
Use Size 0
22CP32W*81
22DP32W*81
22EP32W*81
22FP32W*81
22GP32W*81
22HP32W*81
22IP32W*81
22JG32W*81
—
Catalog
Number
Use Size 0
22CP32F*81
22DP32F*81
22EP32F*81
22FP32F*81
22GP32F*81
22HP32F*81
22IP32F*81
22JG32F*81
List
Catalog
Price $ Number
—
List
Catalog
Price $ Number
Use Size 0
22CP32H*81
22DP32H*81
22EP32H*81
22FP32H*81
22GP32H*81
22HP32H*81
22IP32H*81
22JG32H*81
—
Use Size 0
22CP320*81
22DP320*81
22EP320*81
22FP320*81
22GP320*81
22HP320*81
22IP320*81
22JG320*81
List
Price $
—
Open Type & Standard Width Enclosure, Single Phase, 3-Wire, 2-Pole
Max Hp
Enclosure
Open Type
NEMA 1
General Purpose
NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight
Watertight, Dust-tight
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Corrosion Resistant
304 Stainless Steel
Industrial Use
Weatherproof
Corrosion Resistant
Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
115
Volts
208/
230
Volts
1
⁄3
1
2
3
1
2
3
5
Contactor
Amp
NEMA Catalog
Rating
Size
Number
9
18
27
35
00
0
1
1P
Bolted Enclosures
Indoor/Outdoor Use
List
Catalog
Price $ Number
22BP12A*81
22CP12A*81
22DP12A*81
22EP12A*81
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All Starter Sizes carry
one maximum Hp rating.
8/28
22BP12B*81
22CP12B*81
22DP12B*81
22EP12B*81
List
Catalog
Price $ Number
Use Size 0
22CP12W*81
22DP12W*81
22EP12W*81
List
Price $
—
For
Catalog
Number
Use Size 0
22CP12F*81
22DP12F*81
22EP12F*81
conduit hubs and conversion instructions, see
page 8/88.
Coil D, F, or G will be wired for Incoming Voltage.
J coil will be wired for 24V separate source. Coils E,
H, and L do not apply to single phase starters.
Product Category: NEMA
List
Catalog
Price $ Number
—
Use Size 0
22CP12H*81
22DP12H*81
22EP12H*81
List
Catalog
Price $ Number
—
Use Size 0
22CP120*81
22DP120*81
22EP120*81
List
Price $
—
Auxiliary
contacts
22B-22E 4th pole built-in
22F-22J 2 NO & 2 NC
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Reversing Heavy Duty Starters
Non-Fusible, Class 25
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150.
Fuse clips see page 8/96.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/123.
Wiring Diagrams see page 8/135.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Standard Width Enclosure with Solid State Overload, 3-Phase, 3-Pole
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
200 230 460 575 NEMA Half Amp
Volts Volts Volts Volts Size
Size Range
Frame
Size
Disc.
Amp
Range
Catalog
Number
1
⁄6
⁄2
2
3
1
1
3
1
⁄6
⁄2
2
3
71⁄2
1
1
3
List
Price $
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog
Number
Catalog
Number
List
Price $
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
Catalog
Number
⁄6
⁄4
2
3
1
⁄3
11⁄2
5
—
1
⁄2
2
5
—
0
0
0
0
—
—
—
—
0.25–1
0.75–3.4
3–12
5.5–22
A
A
A1
A1
30
30
30
30
25CUA92B*
25CUB92B*
25CUC92B*
25CUD92B*
25CUA92W*
25CUB92W*
25CUC92W*
25CUD92W*
25CUA92F*
25CUB92F*
25CUC92F*
25CUD92F*
25CUA92N*
25CUB92N*
25CUC92N*
25CUD92N*
⁄6
⁄4
2
3
71⁄2
1
⁄3
11⁄2
5
10
—
1
⁄2
2
5
10
—
1
1
1
1
1
—
—
—
—
—
0.25–1
0.75–3.4
3–12
5.5–22
10–40
A
A
A1
A1
A1
30
30
30
30
60
25DUA92B*
25DUB92B*
25DUC92B*
25DUD92B*
25DUE92B*
25DUA92W*
25DUB92W*
25DUC92W*
25DUD92W*
25DUE92W*
25DUA92F*
25DUB92F*
25DUC92F*
25DUD92F*
25DUE92F*
25DUA92N*
25DUB92N*
25DUC92N*
25DUD92N*
25DUE92N*
10
10
15
15
—
13⁄4
10–40
A1
60
25EUE92B*
25EUE92W*
25EUE92F*
25EUE92N*
10
15
25
25
2
—
13–52
B
60
25FUF92B*
25FUF92W*
25FUF92F*
25FUF92N*
15
20
30
30
—
21⁄2
25–100
B
100
25GUG92B*
25GUG92W*
25GUG92F*
25GUG92N*
20
25
50
50
3
—
25–100
B
100
25HUG92B*
25HUG92W*
25HUG92F*
25HUG92N*
30
40
75
75
—
31⁄2
50–200
B
200
25IUH92B*
25IUH92W*
25IUH92F*
25IUH92N*
40
50
100
100
4
—
50–200
B
200
25JUH92B*
25JUH92W*
25JUH92F*
75
100
200
200
5
—
55–250
—
400
25LPU92B*
25LPU92E*
—
—
25LPU92N*
150
200
400
400
6
—
160–630
—
800
25MPX92B*
25MPX92E*
—
—
25MPX92N*
—
300
600
600
7
—
400–1220
A1+CT
1200
25NUN92B*
—
—
—
—
25NUN92N*
—
450
900
900
8
—
400–1220
A1+CT
1600
25PUN92B*
—
—
—
—
25PUN92N*
List
Price $
25JUH92N*
Standard Width Enclosure with Ambient Compensated Bimetal Overload, 3-Phase, 3-Pole
Max Hp
200
Volts
3
7 1⁄2
10
10
15
25
30
40
230
Volts
3
7 1⁄2
10
15
20
30
40
50
Enclosure
460
Volts
5
10
15
25
30
50
75
100
575
Volts
5
10
15
25
30
50
75
100
Contactor
Amp
NEMA Half
Rating Size
Size
18
0
—
27
1
—
40
—
13⁄4
45
2
—
60
—
21⁄2
90
3
—
115
—
31⁄2
135
4
—
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
Dual
voltage coils not available in modified starters or
in starter sizes 5–8.
conduit hubs and conversion instructions, see
page 8/88.
For
Siemens Industry, Inc.
Industrial Controls Catalog
Disc
Amp
Rating
30
30
60
60
100
100
200
200
NEMA 1
NEMA 4/4X Stainless
NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight, Dust-tight
Corrosion Resistant
Catalog
Number
25CP92W*81
25DP92W*81
25EP92W*81
25FP92W*81
25GP92W*81
25HP92W*81
25IP92W*81
25JP92W*81
Catalog
Number
25CP92F*81
25DP92F*81
25EP92F*81
25FP92F*81
25GP92F*81
25HP92F*81
25IP92F*81
25JP92F*81
Catalog
Number
25CP92B*81
25DP92B*81
25EP92B*81
25FP92B*81
25GP92B*81
25HP92B*81
25IP92B*81
25JP92B*81
List
Price $
Enclosure
is NEMA Type 4 (painted steel).
coil 100-250V AC 50/60Hz, or DC,
H coil 150-500V AC 50/60Hz, or DC
Only available
F coil 100-250V AC 50/60Hz, or DC
F
Product Category: NEMA
List
Price $
NEMA 12
NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight
List
Price $
Catalog
Number
25CP92N*81
25DP92N*81
25EP92N*81
25FP92N*81
25GP92N*81
25HP92N*81
25IP92N*81
25JP92N*81
List
Price $
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
8/29
Combination Reversing Heavy Duty Starters
MCP Type, Class 26
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/123.
Wiring Diagrams see page 8/135.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Standard Width Enclosure with Solid State Overload, 3-Phase, 3-Pole
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
Motor
Circuit
200 230 460 575 NEMA Half Interruter
Volts Volts Volts Volts Size Size ETI Amps
1
1
⁄2
⁄2
1
1
0
— 3
2
2
5
5
0
— 10
3
3
—
—
0
— 25
1
1
⁄2
⁄2
1
1
1
— 3
2
2
5
5
1
— 10
3
3
71⁄2
10
1
— 25
71⁄2
71⁄2
10
—
1
— 30
—
—
15
15
—
13⁄4 40
10
15
25
25
2
— 50
15
20
30
30
—
21⁄2 100
25
30
50
50
3
— 100
30
40
75
75
—
31⁄2 125
40
50
100 100 4
— 150
50
75
150 200 5
— 250
75
100 200 —
5
— 400
100 125 250 300 6
— 400
150 200 400 400 6
— 600
—
250 500 500 7
— 800
—
300 600 600 7
— 1000
—
400 800 800 8
— 1200
—
450 900 900 8
— 1600
Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
160–630
400–1220
400–1220
400–1220
400–1220
Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B
—
—
—
—
A1+CT
A1+CT
A1+CT
A1+CT
Catalog
List
Number
Price $
26CUB92B*
26CUC92B*
26CUD92B*
26DUB92B*
26DUC92B*
26DUD92B*
26DUE92B*
26EUE92B*
26FUF92B*
26GUG92B*
26HUG92B*
26IUH92B*
26JUH92B*
26LPT92B*
26LPU92B*
26MPW92B*
26MPX92B*
26NUV92B*
26NUY92B*
26PUW92B*
26PUZ92B*
NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight,
Watertight, Dust-tight
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Corrosion Resistant
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Div. 1 and Div. 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
Catalog
List
Number
Price $
26CUB92W*
26CUC92W*
26CUD92W*
26DUB92W*
26DUC92W*
26DUD92W*
26DUE92W*
26EUE92W*
26FUF92W*
26GUG92W*
26HUG92W*
26IUH92W*
26JUH92W*
26LPT92E*
26LPU92E*
26MPW92E*
26MPX92E*
—
—
—
—
—
—
—
—
Catalog
List
Number
Price $
26CUB92H*
26CUC92H*
26CUD92H*
26DUB92H*
26DUC92H*
26DUD92H*
26DUE92H*
26EUE92H*
26FUF92H*
26GUG92H*
26HUG92H*
26IUH92H*
26JUH92H*
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Catalog
List
Number
Price $
26CUB92N*
26CUC92N*
26CUD92N*
26DUB92N*
26DUC92N*
26DUD92N*
26DUE92N*
26EUE92N*
26FUF92N*
26GUG92N*
26HUG92N*
26IUH92N*
26JUH92N*
26LPT92N*
26LPU92N*
26MPW92N*
26MPX92N*
26NUV92N*
26NUY92N*
26PUW92N*
26PUZ92N*
26CP92HA*81
26CP92HB*81
26CP92HC*81
26DP92HA*81
26DP92HB*81
26DP92HD*81
26DP92HE*81
26EP92HF*81
26EP92HG*81
26FP92HH*81
26FP92HJ*81
26GP92HK*81
26GP92HL*81
26HP92HM*81
26HP92HN*81
26IP92HP*81
26JP92HR*81
26CP92NA*81
26CP92NB*81
26CP92NC*81
26DP92NA*81
26DP92NB*81
26DP92ND*81
26DP92NE*81
26EP92NF*81
26EP92NG*81
26FP92NH*81
26FP92NJ*81
26GP92NK*81
26GP92NL*81
26HP92NM*81
26HP92NN*81
26IP92NP*81
26JP92NR*81
Catalog
List
Number
Price $
26CUB92F*
26CUC92F*
26CUD92F*
26DUB92F*
26DUC92F*
26DUD92F*
26DUE92F*
26EUE92F*
26FUF92F*
26GUG92F*
26HUG92F*
26IUH92F*
26JUH92F*
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Standard Width Enclosure with Ambient Compensated Bimetal Overload, 3-Phase, 3-Pole
1
⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
10
10
15
—
25
30
40
1
⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
15
15
20
—
30
40
50
1
3
5
1
3
7 1⁄2
10
15
—
20
25
30
—
30
50
75
100
1
3
5
1
3
7 1⁄2
10
15
—
20
25
30
—
30
50
75
100
0
0
0
1
1
1
1
—
—
2
2
—
—
3
3
—
4
—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
—
—
31⁄2
—
3
10
25
3
10
25
30
40
50
40
50
50
100
50
100
125
150
18
18
18
27
27
27
27
40
40
45
45
60
60
90
90
115
135
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
Dual
voltage coils not available in modified starters or
in starter sizes 5–8.
8/30
26CP92BA*81
26CP92BB*81
26CP92BC*81
26DP92BA*81
26DP92BB*81
26DP92BD*81
26DP92BE*81
26EP92BF*81
26EP92BG*81
26FP92BH*81
26FP92BJ*81
26GP92BK*81
26GP92BL*81
26HP92BM*81
26HP92BN*81
26IP92BP*81
26JP92BR*81
26CP92WA*81
26CP92WB*81
26CP92WC*81
26DP92WA*81
26DP92WB*81
26DP92WD*81
26DP92WE*81
26EP92WF*81
26EP92WG*81
26FP92WH*81
26FP92WJ*81
26GP92WK*81
26GP92WL*81
26HP92WM*81
26HP92WN*81
26IP92WP*81
26JP92WR*81
For
conduit hubs and conversion instructions, see
page 8/88.
Enclosure is NEMA Type 4 (painted steel).
F coil 100-250V AC 50/60Hz, or DC,
H coil 150-500V AC 50/60Hz, or DC
Product Category: NEMA
26CP92FA*81
26CP92FB*81
26CP92FC*81
26DP92FA*81
26DP92FB*81
26DP92FD*81
26DP92FE*81
26EP92FF*81
26EP92FG*81
26FP92FH*81
26FP92FJ*81
26GP92FK*81
26GP92FL*81
26HP92FM*81
26HP92FN*81
26IP92FP*81
26JP92FR*81
Only
available
F coil 100-250V AC 50/60Hz, or DC
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
Enclosed
Siemens Industry, Inc.
Industrial Controls Catalog
Two Speed Heavy Duty Starters
Features and Benefits
General
Features
▪
▪
▪
▪
Rugged Industrial Design
Dual Voltage, Dual Frequency Coils
Compact Design
Snap-On Front Removable Auxiliary
Contacts
▪ Electrical and Mechanical Interlocks
▪ Half Sizes — Space and Cost Savings
▪ Industrial Type Disconnect
Operating Handle
▪ Visible Blade Disconnect Thru Size 4
▪ Adjustable Motor Circuit Protector
▪ 100,000 Amp Fault Protection with
MCP or Class R Fuses
▪ Pilot Device Locations identified
on All Enclosures
▪ UL Listed File #E14900
▪ CSA Certified File #LR6535
Applications
Multi-speed magnetic starters
automatically reconnect multi-speed
motor windings for the desired speed in
response to a signal received from push
button stations or other pilot devices.
These starters are available for two
speed motors.
Consequent Pole multi-speed motors
having two speeds on a single winding
(consequent pole) require a starter
which reconnects the motor leads to
half the number of effective motor
poles at the high speed point. In this
type of motor, the low speed is one
half the high speed.
Separate Windings motors having
separate windings for each speed
provide more varied speed
combinations in that the low speed
need not be one half the high speed.
motor is applicable to fans, blowers
and centrifugal pumps.
Constant Horsepower motors
maintain constant horsepower at all
speeds and therefore torque varies
inversely with speed. This type of
motor is applicable where the same
horsepower is required at all speeds.
The higher current required at
low speed requires derating on
starters for constant horsepower
applications. This type of motor is
applicable to metal working machines
such as drills, lathes, mills, bending
machines, punch presses, and power
wrenches.
Operation
Magnetic starters for multi-speed
applications select the desired speed
in accordance with the pilot control.
The shock to machinery upon the
reduction of speed is greater than when
the speed is increased. Therefore, the
pilot control should be wired so that the
stop button must be depressed before
dropping to a lower speed or time
delays should be used for applications
requiring full automatic operations. The
multi-speed controls are available with
the necessary interlocks or relays to
provide this type of operation.
Compelling Control requires that the
motor always be started at the lower
speed and that the push buttons be
operated in speed sequence to go to
the next higher speed. To change to a
lower speed, the stop button must be
depressed and then the push buttons
operated in speed sequence until the
desired speed is reached. Compelling
control can be added from the factory
modification section page 8/98.
Acceleration Control provides that
the motor be accelerated automatically
with timers by progressively energizing
the controls from the push button
station from the lowest to highest
speed. To change to a lower speed the
stop button is depressed and then it is
necessary to proceed as if starting from
rest. Acceleration control can be added
from the factory modification section
page 8/98.
Deceleration Control provides that
the motor be decelerated automatically
with a timer when going from high
speed to low speed. The timer allows
the motor to decelerate from high
speed to a lower speed before
automatically restarting the motor in
low speed. Deceleration control can be
added from the factory modification
section page 8/98.
These controls may be modified for
compelling or acceleration pilot control.
Selective Control permits the
operator to start the motor at any speed
and to change to a higher speed by
merely pushing a button. To change to
a lower speed it is necessary to first
depress the stop button and to then
press the proper speed button.
Selective control is a function of the
pilot control selected and requires no
starter modifications.
Open Style Two Speed Starter
(ESP100 Overload)
Starters for separate winding
motors consist of a starter unit
for each speed.
Multi-speed motor starters are available
for constant torque, variable torque and
constant horsepower motors.
Constant Torque motors maintain
constant torque at all speeds.
Horsepower varies directly with speed.
This type of motor is applicable to
conveyors, mills and similar
applications.
Open Style Two Speed Starter
(Ambient Compensated Overload)
Variable Torque motors produce a
torque characteristic which varies as
the square of the speed. This type of
Siemens Industry, Inc.
Industrial Controls Catalog
8/31
Two Speed Heavy Duty Starters
Constant or Variable Torque with Solid Overload, Class 30
Selection
Ordering Information
䊳
Coil Table
Replace the (*) with a letter from
the coil table. Dual voltage coils
are wired on high voltage unless
specified on order.
䊳
Replace the (†) with the letter that
corresponds to the correct low
speed FLA in the FLA table.
䊳
Field Modification Kits see page 8/82.
䊳
Factory Modifications see page 8/95.
䊳
Dimensions see page 8/124.
䊳
Wiring Diagrams see page 8/136.
䊳
Replacement Parts see page 8/157.
2S2W Starter
(ESP200 Overload)
60Hz Voltage
Low Speed FLA Table
Letter
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
J
F
A
D
G
L
C
H
E
Size
FLA
OLR
Frame Size
†
0,1
0,1
0,1
0,1
0-13/4
2-3
2-3
21/2-4
0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200
A
A
A1
A1
A1
B
B
B
A
B
C
D
E
F
G
H
For other voltages and frequencies,
see Factory Modifications page 8/95.
One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)
Max Hp
200
Volts
1
⁄2
2
3
1
⁄2
2
3
71⁄2
10
10
15
25
30
40
230
Volts
3
⁄4
2
3
3
⁄4
2
3
71⁄2
10
15
20
30
40
50
Overload
460
Volts
11⁄2
5
—
11⁄2
5
10
—
15
25
30
50
75
100
575
Volts
2
5
—
11⁄2
5
10
—
15
25
30
50
75
100
NEMA
Size
0
0
0
1
1
1
1
—
2
—
3
—
4
Half
Size
—
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B
Enclosure
Open Type
NEMA 1
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Standard Auxiliary Contacts
General Purpose
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
Catalog
List
Catalog
List
Catalog
List
Catalog
List
Catalog
List
Number
Price $ Number
Price $ Number
Price $ Number
Price $ Number
Price $
30CUB†32A2V*
30CUB†32B2V*
30CUB†32W2V*
30CUB†32F2V*
30CUB†3202V*
30CUC†32A2V*
30CUC†32B2V*
30CUC†32W2V*
30CUC†32F2V*
30CUC†3202V*
30CUD†32A2V*
30CUD†32B2V*
30CUD†32W2V*
30CUD†32F2V*
30CUD†3202V*
30DUB†32A2V*
30DUB†32B2V*
30DUB†32W2V*
30DUB†32F2V*
30DUB†3202V*
30DUC†32A2V*
30DUC†32B2V*
30DUC†32W2V*
30DUC†32F2V*
30DUC†3202V*
30DUD†32A2V*
30DUD†32B2V*
30DUD†32W2V*
30DUD†32F2V*
30DUD†3202V*
30DUE†32A2V*
30DUE†32B2V*
30DUE†32W2V*
30DUE†32F2V*
30DUE†3202V*
30EUE†32A2V*
30EUE†32B2V*
30EUE†32W2V*
30EUE†32F2V*
30EUE†3202V*
30FUF†32A2V*
30FUF†32B2V*
30FUF†32W2V*
30FUF†32F2V*
30FUF†3202V*
30GUG†32A2V*
30GUG†32B2V*
30GUG†32W2V*
30GUG†32F2V*
30GUG†3202V*
30HUG†32A2V*
30HUG†32B2V*
30HUG†32W2V*
30HUG†32F2V*
30HUG†3202V*
30IUH†32A2V*
30IUH†32B2V*
30IUH†32W2V*
30IUH†32F2V*
30IUH†3202V*
30JUH†32A2V*
30JUH†32B2V*
30JUH†32W2V*
30JUH†32F2V*
30JUH†3202V*
Two Separate Windings, 3-Phase (Constant or Variable Torque)
Max Hp
200
Volts
1
⁄2
2
3
1
⁄2
2
3
71⁄2
10
10
15
25
30
40
230
Volts
3
⁄4
2
3
3
⁄4
2
3
71⁄2
10
15
20
30
40
50
Overload
460
Volts
11⁄2
5
—
11⁄2
5
10
—
15
25
30
50
75
100
575
Volts
2
5
—
11⁄2
5
10
—
15
25
30
50
75
100
NEMA
Size
0
0
0
1
1
1
1
—
2
—
3
—
4
Half
Size
—
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
For conduit hubs and conversion instructions, see
page 8/88.
8/32
Enclosure
Open Type
NEMA 1
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Standard Auxiliary Contacts
General Purpose
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
Catalog
List
Catalog
List
Catalog
List
Catalog
List
Catalog
List
Number
Price $ Number
Price $ Number
Price $ Number
Price $ Number
Price $
30CUB†32A1V*
30CUB†32B1V*
30CUB†32W1V*
30CUB†32F1V*
30CUB†3201V*
30CUC†32A1V*
30CUC†32B1V*
30CUC†32W1V*
30CUC†32F1V*
30CUC†3201V*
30CUD†32A1V*
30CUD†32B1V*
30CUD†32W1V*
30CUD†32F1V*
30CUD†3201V*
30DUB†32A1V*
30DUB†32B1V*
30DUB†32W1V*
30DUB†32F1V*
30DUB†3201V*
30DUC†32A1V*
30DUC†32B1V*
30DUC†32W1V*
30DUC†32F1V*
30DUC†3201V*
30DUD†32A1V*
30DUD†32B1V*
30DUD†32W1V*
30DUD†32F1V*
30DUD†3201V*
30DUE†32A1V*
30DUE†32B1V*
30DUE†32W1V*
30DUE†32F1V*
30DUE†3201V*
30EUE†32A1V*
30EUE†32B1V*
30EUE†32W1V*
30EUE†32F1V*
30EUE†3201V*
30FUF†32A1V*
30FUF†32B1V*
30FUF†32W1V*
30FUF†32F1V*
30FUF†3201V*
30GUG†32A1V*
30GUG†32B1V*
30GUG†32W1V*
30GUG†32F1V*
30GUG†3201V*
30HUG†32A1V*
30HUG†32B1V*
30HUG†32W1V*
30HUG†32F1V*
30HUG†3201V*
30IUH†32A1V*
30IUH†32B1V*
30IUH†32W1V*
30IUH†32F1V*
30IUH†3201V*
30JUH†32A1V*
30JUH†32B1V*
30JUH†32W1V*
30JUH†32F1V*
30JUH†3201V*
If motor FLA are unknown, select overload on the
basis that low speed FLA will be no greater than 50%
of high speed FLA.
Auxiliary contacts 30C-30E 4th pole built-in
30F-30J 2 NO & 2 NC
Product Category: NEMA
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
Siemens Industry, Inc.
Industrial Controls Catalog
Two Speed Heavy Duty Starters
Constant HP with Solid Overload, Class 30
Selection
Ordering Information
䊳
High/Low Speed FLA Table
Coil Table
Replace the (*) with a letter from
the coil table. Dual voltage coils
are wired on high voltage unless
specified on order.
60Hz Voltage
䊳
Replace the (†) with the letter that
corresponds to the correct FLA in
High/Low Speed FLA Table.
䊳
Field Modification Kits see page
8/82.
䊳
Factory Modifications see page 8/95.
䊳
Dimensions see page 8/124.
䊳
Wiring Diagrams see page 8/136.
䊳
Replacement Parts see page 8/157.
Letter
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
J
F
A
D
G
L
C
H
E
Size
FLA
OLR
Frame Size
†
0,1
0,1
0,1
0,1
0-13/4
2-3
2-3
21/2-4
0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200
A
A
A1
A1
A1
B
B
B
A
B
C
D
E
F
G
H
For other voltages and frequencies,
see Factory Modifications page 8/95.
2S2W Starter
(ESP200 Overload)
* First (†) for high speed, second (†)
for low speed. Use motor nameplate
to select FLA. If motor FLA are
unknown, select overload on the
bases that the low speed FLA will
be no greater than 50 % of high
speed FLA.
One Winding Consequent Pole, 3-Phase (Constant Horsepower)
Max Hp
Enclosure
Open Type
NEMA 1
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Standard Auxiliary Contacts
General Purpose
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog
Number
Catalog
Number
200 230 460 575 NEMA Half Catalog
Volts Volts Volts Volts Size
Size Number
List
Price $
Catalog
Number
List
Price $
List
Price $
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
Catalog
Number
2
2
3
3
0
—
30CU††32A2H*
30CU††32B2H*
30CU††32W2H*
30CU††32F2H*
30CU††3202H*
5
5
71⁄2
71⁄2
1
—
30DU††32A2H*
30DU††32B2H*
30DU††32W2H*
30DU††32F2H*
30DU††3202H*
71⁄2
71⁄2
10
10
—
13⁄4
30EU††32A2H*
30EU††32B2H*
30EU††32W2H*
30EU††32F2H*
30EU††3202H*
71⁄2
10
20
20
2
—
30FU††32A2H*
30FU††32B2H*
30FU††32W2H*
30FU††32F2H*
30FU††3202H*
10
15
25
25
—
21⁄2
30GU††32A2H*
30GU††32B2H*
30GU††32W2H*
30GU††32F2H*
30GU††3202H*
20
25
40
40
3
—
30HU††32A2H*
30HU††32B2H*
30HU††32W2H*
30HU††32F2H*
30HU††3202H*
25
30
50
50
—
31⁄2
30IU††32A2H*
30IU††32B2H*
30IU††32W2H*
30IU††32F2H*
30IU††3202H*
30
40
75
75
4
—
30JU††32A2H*
30JU††32B2H*
30JU††32W2H*
30JU††32F2H*
30JU††3202H*
NEMA 12
NEMA 3/3R
List
Price $
Two Separate Windings, 3-Phase (Constant Horsepower)
Max Hp
Enclosure
Open Type
NEMA 1
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Standard Auxiliary Contacts
General Purpose
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog
Number
Catalog
Number
200 230 460 575 NEMA Half Catalog
Volts Volts Volts Volts Size
Size Number
List
Price $
Catalog
Number
List
Price $
List
Price $
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
Catalog
Number
2
2
3
3
0
—
30CU††32A1H*
30CU††32B1H*
30CU††32W1H*
30CU††32F1H*
30CU††3201H*
5
5
71⁄2
71⁄2
1
—
30DU††32A1H*
30DU††32B1H*
30DU††32W1H*
30DU††32F1H*
30DU††3201H*
71⁄2
71⁄2
10
10
—
13⁄4 30EU††32A1H*
30EU††32B1H*
30EU††32W1H*
30EU††32F1H*
30EU††3201H*
71⁄2
10
20
20
2
—
30FU††32A1H*
30FU††32B1H*
30FU††32W1H*
30FU††32F1H*
30FU††3201H*
10
15
25
25
—
21⁄2
30GU††32A1H*
30GU††32B1H*
30GU††32W1H*
30GU††32F1H*
30GU††3201H*
20
25
40
40
3
—
30HU††32A1H*
30HU††32B1H*
30HU††32W1H*
30HU††32F1H*
30HU††3201H*
25
30
50
50
—
31⁄2
30IU††32A1H*
30IU††32B1H*
30IU††32W1H*
30IU††32F1H*
30IU††3201H*
30
40
75
75
4
—
30JU††32A1H*
30JU††32B1H*
30JU††32W1H*
30JU††32F1H*
30JU††3201H*
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
For conduit hubs and conversion instructions, see
page 8/88.
Siemens Industry, Inc.
Industrial Controls Catalog
First (†) for high speed, second (†) for low speed. Use
motor nameplate information to select FLA. If motor
FLA are unknown, select overload on the basis that
low speed FLA will be no greater than 50% of high
speed FLA.
Product Category: NEMA
List
Price $
Auxiliary contacts
30C-30E 4th pole built-in
30F-30J 2 NO & 2 NC
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
Enclosed
8/33
Two Speed Heavy Duty Starters
Constant or Variable Torque with Ambient Compensated Bimetal Overload, Class 30
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150 (6 required)
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/106 open and 8/124 enclosed.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
2S2W starter
(Amb. Comp. Bimetal OL)
One Winding Consequent Pole, 3 Phase (Constant or Variable Torque)
Max Hp
Enclosure
Open Type
200
Volts
230
Volts
460
Volts
NEMA 1
NEMA 4/4X Stainless
NEMA 4X Fiberglass
NEMA 12
General Purpose
Watertight, Dust-tight
Watertight, Dust-tight
NEMA 3/3R
ContCorrosion Resistant
Corrosion Resistant
Industrial Use
actor
304 Stainless Steel
Weatherproof
575 Amp NEMA Half
Volts Rating Size Size Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $
3
7 1⁄2
10
10
15
25
30
40
3
7 1⁄2
10
15
20
30
40
50
5
10
15
25
30
50
75
100
5
10
15
25
30
50
75
100
18
27
40
45
60
90
115
135
0
1
—
2
—
3
—
4
—
—
13⁄4
—
21⁄2
—
31⁄2
—
30CP32A2V*81
30DP32A2V*81
30EP32A2V*81
30FP32A2V*81
30GP32A2V*81
30HP32A2V*81
30IP32A2V*81
30JG32A2V*81
30CP32B2V*81
30DP32B2V*81
30EP32B2V*81
30FP32B2V*81
30GP32B2V*81
30HP32B2V*81
30IP32B2V*81
30JG32B2V*81
30CP32W2V*81
30DP32W2V*81
30EP32W2V*81
30FP32W2V*81
30GP32W2V*81
30HP32W2V*81
30IP32W2V*81
30JG32W2V*81
30CP32F2V*81
30DP32F2V*81
30EP32F2V*81
30FP32F2V*81
30GP32F2V*81
30HP32F2V*81
30IP32F2V*81
30JG32F2V*81
30CP3202V*81
30DP3202V*81
30EP3202V*81
30FP3202V*81
30GP3202V*81
30HP3202V*81
30IP3202V*81
30JG3202V*81
Two Separate Windings, 3-Phase (Constant or Variable Torque)
Max Hp
Enclosure
200
Volts
230
Volts
Open Type
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
NEMA 12
General Purpose
Watertight, Dust-tight
Watertight, Dust-tight
NEMA 3/3R
ContCorrosion Resistant
Corrosion Resistant
Industrial Use
actor
304 Stainless Steel
Weatherproof
460 575 Amp NEMA Half
Volts Volts Rating Size Size Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $
3
7 1⁄2
10
10
15
25
30
40
3
7 1⁄2
10
15
20
30
40
50
5
10
15
25
30
50
75
100
5
10
15
25
30
50
75
100
18
27
40
45
60
90
115
135
0
1
—
2
—
3
—
4
—
—
13⁄4
—
21⁄2
—
31⁄2
—
30CP32A1V*81
30DP32A1V*81
30EP32A1V*81
30FP32A1V*81
30GP32A1V*81
30HP32A1V*81
30IP32A1V*81
30JG32A1V*81
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.
8/34
30CP32B1V*81
30DP32B1V*81
30EP32B1V*81
30FP32B1V*81
30GP32B1V*81
30HP32B1V*81
30IP32B1V*81
30JG32B1V*81
30CP32W1V*81
30DP32W1V*81
30EP32W1V*81
30FP32W1V*81
30GP32W1V*81
30HP32W1V*81
30IP32W1V*81
30JG32W1V*81
For conduit hubs and conversion instructions,
see page 8/88.
If motor FLA are unknown, select heater elements on
30CP32F1V*81
30DP32F1V*81
30EP32F1V*81
30FP32F1V*81
30GP32F1V*81
30HP32F1V*81
30IP32F1V*81
30JG32F1V*81
30CP3201V*81
30DP3201V*81
30EP3201V*81
30FP3201V*81
30GP3201V*81
30HP3201V*81
30IP3201V*81
30JG3201V*81
Auxiliary
contacts
30C-30E 4th pole built-in
30F-30J 2 NO & 2 NC
the basis that low speed FLA will be no greater than
50% of high speed FLA.
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Two Speed Heavy Duty Starters
Constant HP with Ambient Compensated Bimetal Overload, Class 30
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150 (6 required)
.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/106 open and 8/124 enclosed.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
2S2W starter
(Amb. Comp. Bimetal OL)
One Winding Consequent Pole, 3-Phase (Constant Horsepower)
Max Hp
Enclosure
200
Volts
Open Type
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
NEMA 12
General Purpose
Watertight, Dust-tight
Watertight, Dust-tight
NEMA 3/3R
ContCorrosion Resistant
Corrosion Resistant
Industrial Use
actor
304 Stainless Steel
Weatherproof
230
460 575 Amp NEMA Half
Volts Volts Volts Rating Size
Size Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $
2
5
7 1⁄2
7 1⁄2
10
20
25
30
2
5
7 1⁄2
10
15
25
30
40
3
7 1⁄2
10
20
25
40
50
75
3
7 1⁄2
10
20
25
40
50
75
18
27
40
45
60
90
115
135
0
1
—
2
—
3
—
4
—
—
13⁄4
—
21⁄2
—
31⁄2
—
30CP32A2H*81
30DP32A2H*81
30EP32A2H*81
30FP32A2H*81
30GP32A2H*81
30HP32A2H*81
30IP32A2H*81
30JG32A2H*81
30CP32B2H*81
30DP32B2H*81
30EP32B2H*81
30FP32B2H*81
30GP32B2H*81
30HP32B2H*81
30IP32B2H*81
30JG32B2H*81
30CP32W2H*81
30DP32W2H*81
30EP32W2H*81
30FP32W2H*81
30GP32W2H*81
30HP32W2H*81
30IP32W2H*81
30JG32W2H*81
30CP32F2H*81
30DP32F2H*81
30EP32F2H*81
30FP32F2H*81
30GP32F2H*81
30HP32F2H*81
30IP32F2H*81
30JG32F2H*81
30CP3202H*81
30DP3202H*81
30EP3202H*81
30FP3202H*81
30GP3202H*81
30HP3202H*81
30IP3202H*81
30JG3202H*81
Two Separate Windings, 3-Phase (Constant Horsepower)
Max Hp
Enclosure
Open Type
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
NEMA 12
General Purpose
Watertight, Dust-tight
Watertight, Dust-tight
NEMA 3/3R
ContCorrosion Resistant
Corrosion Resistant
Industrial Use
actor
304 Stainless Steel
Weatherproof
200 230 460 575 Amp NEMA Half
Volts Volts Volts Volts Rating Size Size Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $ Catalog Number List Price $
2
5
7 1⁄2
7 1⁄2
10
20
25
30
2
5
7 1⁄2
10
15
25
30
40
3
7 1⁄2
10
20
25
40
50
75
3
7 1⁄2
10
20
25
40
50
75
18
27
40
45
60
90
115
135
0
1
—
2
—
3
—
4
—
—
13⁄4
—
21⁄2
—
31⁄2
—
30CP32A1H*81
30DP32A1H*81
30EP32A1H*81
30FP32A1H*81
30GP32A1H*81
30HP32A1H*81
30IP32A1H*81
30JG32A1H*81
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.
30CP32B1H*81
30DP32B1H*81
30EP32B1H*81
30FP32B1H*81
30GP32B1H*81
30HP32B1H*81
30IP32B1H*81
30JG32B1H*81
30CP32W1H*81
30DP32W1H*81
30EP32W1H*81
30FP32W1H*81
30GP32W1H*81
30HP32W1H*81
30IP32W1H*81
30JG32W1H*81
If motor FLA are unknown, select heater element on
the basis that low speed FLA will be no greater than
50% of high speed FLA.
30CP32F1H*81
30DP32F1H*81
30EP32F1H*81
30FP32F1H*81
30GP32F1H*81
30HP32F1H*81
30IP32F1H*81
30JG32F1H*81
30CP3201H*81
30DP3201H*81
30EP3201H*81
30FP3201H*81
30GP3201H*81
30HP3201H*81
30IP3201H*81
30JG3201H*81
Auxiliary contacts
30C-30E 4th pole built-in
30F-30J 2 NO & 2 NC
For conduit hubs and conversion instructions,
see page 8/88.
Siemens Industry, Inc.
Industrial Controls Catalog
Product Category: NEMA
8/35
Combination Two Speed Heavy Duty Starters
Non-Fusible, Constant or Variable Torque with Solid Overload, Class 32
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from
the coil table. Dual voltage coils
are wired on high voltage unless
specified on order.
Replace the (†) with the letter that
corresponds to the correct low
speed FLA in the FLA table.
Fuse clips see page 8/96.
Field Modification Kits see page
8/82.
Factory Modifications see page
8/95.
Dimensions see page 8/125.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.
Low Speed FLA Table
60Hz Voltage
Letter
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
J
F
A
D
G
L
C
H
E
Size
FLA
OLR
Frame Size
†
0,1
0,1
0,1
0,1
0-13/4
2-3
2-3
21/2-4
0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200
A
A
A1
A1
A1
B
B
B
A
B
C
D
E
F
G
H
For other voltages and frequencies,
see Factory Modifications page 8/95.
One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
200
Volts
1
⁄2
2
3
1
⁄2
2
3
71⁄2
10
10
15
20
30
40
230
Volts
3
⁄4
2
3
3
⁄4
2
3
71⁄2
10
15
20
25
40
50
460
Volts
11⁄2
5
—
11⁄2
5
10
—
15
25
30
50
75
100
575
Volts
2
5
—
11⁄2
5
10
—
15
25
30
50
75
100
NEMA
Size
0
0
0
1
1
1
1
—
2
—
3
—
4
Half
Size
—
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B
Disc.
Amp
Range
30
30
30
30
30
30
60
60
60
100
100
200
200
Catalog
Number
32CUB†92B2V2*
32CUC†92B2V2*
32CUD†92B2V2*
32DUB†92B2V2*
32DUC†92B2V2*
32DUD†92B2V2*
32DUE†92B2V2*
32EUE†92B2V2*
32FUF†92B2V2*
32GUG†92B2V2*
32HUG†92B2V2*
32IUH†92B2V2*
32JUH†92B2V2*
List
Price $
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog
Number
32CUB†92W2V2*
32CUC†92W2V2*
32CUD†92W2V2*
32DUB†92W2V2*
32DUC†92W2V2*
32DUD†92W2V2*
32DUE†92W2V2*
32EUE†92W2V2*
32FUF†92W2V2*
32GUG†92W2V2*
32HUG†92W2V2*
32IUH†92W2V2*
32JUH†92W2V2*
Catalog
Number
32CUB†92F2V2*
32CUC†92F2V2*
32CUD†92F2V2*
32DUB†92F2V2*
32DUC†92F2V2*
32DUD†92F2V2*
32DUE†92F2V2*
32EUE†92F2V2*
32FUF†92F2V2*
32GUG†92F2V2*
32HUG†92F2V2*
32IUH†92F2V2*
32JUH†92F2V2*
List
Price $
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
Catalog
Number
32CUB†92N2V2*
32CUC†92N2V2*
32CUD†92N2V2*
32DUB†92N2V2*
32DUC†92N2V2*
32DUD†92N2V2*
32DUE†92N2V2*
32EUE†92N2V2*
32FUF†92N2V2*
32GUG†92N2V2*
32HUG†92N2V2*
32IUH†92N2V2*
32JUH†92N2V2*
List
Price $
Two Separate Windings, 3-Phase (Constant or Variable Torque)
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
200
Volts
1
⁄2
2
3
1
⁄2
2
3
71⁄2
10
10
15
20
30
40
230
Volts
3
⁄4
2
3
3
⁄4
2
3
71⁄2
10
15
20
25
40
50
460
Volts
11⁄2
5
—
11⁄2
5
10
—
15
25
30
50
75
100
575
Volts
2
5
—
11⁄2
5
10
—
15
25
30
50
75
100
NEMA
Size
0
0
0
1
1
1
1
—
2
—
3
—
4
Half
Size
—
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
Dual voltage coils not available in modified starters.
8/36
Disc.
Amp
Range
30
30
30
30
30
30
60
60
60
100
100
200
200
Catalog
Number
32CUB†92B1V2*
32CUC†92B1V2*
32CUD†92B1V2*
32DUB†92B1V2*
32DUC†92B1V2*
32DUD†92B1V2*
32DUE†92B1V2*
32EUE†92B1V2*
32FUF†92B1V2*
32GUG†92B1V2*
32HUG†92B1V2*
32IUH†92B1V2*
32JUH†92B1V2*
List
Price $
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog
Number
32CUB†92W1V2*
32CUC†92W1V2*
32CUD†92W1V2*
32DUB†92W1V2*
32DUC†92W1V2*
32DUD†92W1V2*
32DUE†92W1V2*
32EUE†92W1V2*
32FUF†92W1V2*
32GUG†92W1V2*
32HUG†92W1V2*
32IUH†92W1V2*
32JUH†92W1V2*
Catalog
Number
32CUB†92F1V2*
32CUC†92F1V2*
32CUD†92F1V2*
32DUB†92F1V2*
32DUC†92F1V2*
32DUD†92F1V2*
32DUE†92F1V2*
32EUE†92F1V2*
32FUF†92F1V2*
32GUG†92F1V2*
32HUG†92F1V2*
32IUH†92F1V2*
32JUH†92F1V2*
For
List
Price $
conduit hubs and conversion instructions, see
page 8/88.
If motor FLA are unknown, select overload on the
basis that low speed FLA will be no greater than 50%
of high speed FLA.
Product Category: NEMA
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
Catalog
Number
32CUB†92N1V2*
32CUC†92N1V2*
32CUD†92N1V2*
32DUB†92N1V2*
32DUC†92N1V2*
32DUD†92N1V2*
32DUE†92N1V2*
32EUE†92N1V2*
32FUF†92N1V2*
32GUG†92N1V2*
32HUG†92N1V2*
32IUH†92N1V2*
32JUH†92N1V2*
List
Price $
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Two Speed Heavy Duty Starters
Non-Fusible, Constant Horsepower with Solid State Overload, Class 32
Selection
High/Low Speed FLA Table
Coil Table
Ordering Information
Replace the (*) with a letter from
the coil table. Dual voltage coils are
wired on high voltage unless
specified on order.
䊳 Replace the (†) with the letter that
corresponds to the correct FLA in the
High/Low Speed FLA Table.
䊳 Fuse clips see page 8/96.
䊳 Field Modification Kits see page 8/82.
䊳 Factory Modifications see page 8/95.
䊳 Dimensions see page 8/125.
䊳 Wiring Diagrams see page 8/136.
䊳 Replacement Parts see page 8/157.
䊳
60Hz Voltage
Letter
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
For other voltages and
frequencies see Factory
Modifications page 8/95.
J
F
A
D
G
L
C
H
E
Size
FLA
OLR
Frame Size
†
0,1
0,1
0,1
0,1
0-13/4
2-3
2-3
21/2-4
0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200
A
A
A1
A1
A1
B
B
B
A
B
C
D
E
F
G
H
* First (†) for high speed, second (†)
for low speed. Use motor nameplate
to select FLA. If motor FLA are
unknown, select overload on the
bases that the low speed FLA will
be no greater than 50 % of high
speed FLA.
One Winding Consequent Pole, 3-Phase (Constant Horsepower)
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog
Number
Catalog
Number
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
200 230 460 575 NEMA Half Amp
Volts Volts Volts Volts Size
Size Range
Disc.
Frame Amp Catalog
Size Range Number
2
2
3
3
0
—
—
—
30
32CU††92B2H2*
32CU††92W2H2*
32CU††92F2H2*
32CU††92N2H2*
5
5
71⁄2
71⁄2
1
—
—
—
30
32DU††92B2H2*
32DU††92W2H2*
32DU††92F2H2*
32DU††92N2H2*
71⁄2
71⁄2
10
10
—
13⁄4
—
—
60
32EU††92B2H2*
32EU††92W2H2*
32EU††92F2H2*
32EU††92N2H2*
71⁄2
10
20
20
2
—
—
—
60
32FU††92B2H2*
32FU††92W2H2*
32FU††92F2H2*
32FU††92N2H2*
10
15
25
25
—
21⁄2
—
—
100
32GU††92B2H2*
32GU††92W2H2*
32GU††92F2H2*
32GU††92N2H2*
20
25
40
40
3
—
—
—
100
32HU††92B2H2*
32HU††92W2H2*
32HU††92F2H2*
32HU††92N2H2*
25
30
50
50
—
31⁄2
—
—
200
32IU††92B2H2*
32IU††92W2H2*
32IU††92F2H2*
32IU††92N2H2*
30
40
75
75
4
—
—
—
200
32JU††92B2H2*
32JU††92W2H2*
32JU††92F2H2*
32JU††92N2H2*
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
NEMA 12
NEMA 3/3R
Catalog
Number
Catalog
Number
List
Price $
List
Price $
List
Price $
Catalog
Number
List
Price $
Two Separate Windings, 3-Phase (Constant Horsepower)
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
200 230 460 575 NEMA Half Amp
Volts Volts Volts Volts Size
Size Range
Disc.
Frame Amp Catalog
Size Range Number
2
2
3
3
0
—
—
—
30
32CU††92B1H2*
32CU††92W1H2*
32CU††92F1H2*
32CU††92N1H2*
5
5
71⁄2
71⁄2
1
—
—
—
30
32DU††92B1H2*
32DU††92W1H2*
32DU††92F1H2*
32DU††92N1H2*
71⁄2
71⁄2
10
10
—
13⁄4
—
—
60
32EU††92B1H2*
32EU††92W1H2*
32EU††92F1H2*
32EU††92N1H2*
71⁄2
10
20
20
2
—
—
—
60
32FU††92B1H2*
32FU††92W1H2*
32FU††92F1H2*
32FU††92N1H2*
10
15
25
25
—
21⁄2
—
—
100
32GU††92B1H2*
32GU††92W1H2*
32GU††92F1H2*
32GU††92N1H2*
20
25
40
40
3
—
—
—
100
32HU††92B1H2*
32HU††92W1H2*
32HU††92F1H2*
32HU††92N1H2*
25
30
50
50
—
31⁄2
—
—
200
32IU††92B1H2*
32IU††92W1H2*
32IU††92F1H2*
32IU††92N1H2*
30
40
75
75
4
—
—
—
200
32JU††92B1H2*
32JU††92W1H2*
32JU††92F1H2*
32JU††92N1H2*
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
Dual voltage coils not available in modified starters.
For conduit hubs and conversion instructions, see
page 8/88.
Siemens Industry, Inc.
Industrial Controls Catalog
List
Price $
First
List
Price $
† for high speed, second † for low speed. Use
motor nameplate information to select FLA. If motor
FLA are unknown, select overload on the basis that
low speed FLA will be no greater than 50% of high
speed FLA.
Enclosed starters with the ESP200 OLR will not be
Product Category: NEMA
List
Price $
Catalog
Number
List
Price $
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
8/37
Combination Two Speed Heavy Duty Starters
Non-Fusible, Constant or Variable Torque with Ambient Compensated Bimetal Overload, Class 32
Selection
Ordering Information
Coil Table
䊳
60Hz Voltage
Replace the (*) with a letter from the coil
table. Dual voltage coils are wired on high
voltage unless specified on order.
䊳
Heater elements see page 8/150. (6 required)
䊳
Fuse clips see page 8/96.
䊳
Field Modification Kits see page 8/82.
䊳
Factory Modifications see page 8/95.
䊳
Dimensions see page 8/125.
䊳
Wiring Diagrams see page 8/136.
䊳
Replacement Parts see page 8/157.
Letter
24 Separate Control
120 Separate Control
110–120/220–240
J
F
A
200–208
D
220–240
G
277
L
220–240/440–480
C
440–480
H
575–600
E
For other voltages and frequencies, see Factory
Modifications page 8/95.
One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)
Max Hp
Enclosure
200
230
Volts Volts
3
7 1⁄2
10
10
15
20
30
40
3
7 1⁄2
10
15
20
25
40
50
460
Volts
575
Volts
Contactor
Amp
NEMA Half
Rating Size
Size
5
10
15
25
30
50
75
100
5
10
15
25
30
50
75
100
18
27
40
45
60
90
115
135
0
1
—
2
—
3
—
4
—
—
13⁄4
—
21⁄2
—
31⁄2
—
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight, Dust-tight
Corrosion Resistant
Disc
Amp
Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number
30
30
60
60
100
100
200
200
32CP92B2V2*81
32DP92B2V2*81
32EP92B2V2*81
32FP92B2V2*81
32GP92B2V2*81
32HP92B2V2*81
32IP92B2V2*81
32JP92B2V2*81
32CP92W2V2*81
32DP92W2V2*81
32EP92W2V2*81
32FP92W2V2*81
32GP92W2V2*81
32HP92W2V2*81
32IP92W2V2*81
32JP92W2V2*81
NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight
List Price $ Catalog Number
32CP92F2V2*81
32DP92F2V2*81
32EP92F2V2*81
32FP92F2V2*81
32GP92F2V2*81
32HP92F2V2*81
32IP92F2V2*81
32JP92F2V2*81
List Price $
32CP92N2V2*81
32DP92N2V2*81
32EP92N2V2*81
32FP92N2V2*81
32GP92N2V2*81
32HP92N2V2*81
32IP92N2V2*81
32JP92N2V2*81
Two Separate Windings, 3-Phase (Constant or Variable Torque)
Max Hp
200
230
Volts Volts
3
7 1⁄2
10
10
15
20
30
40
3
7 1⁄2
10
15
20
25
40
50
Enclosure
460
Volts
5
10
15
25
30
50
75
100
575
Volts
5
10
15
25
30
50
75
100
Contactor
Amp
NEMA Half
Rating Size Size
18
27
40
45
60
90
115
135
0
1
—
2
—
3
—
4
—
—
13⁄4
—
21⁄2
—
31⁄2
—
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.
8/38
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight, Dust-tight
Corrosion Resistant
32CP92W1V2*81
32DP92W1V2*81
32EP92W1V2*81
32FP92W1V2*81
32GP92W1V2*81
32HP92W1V2*81
32IP92W1V2*81
32JP92W1V2*81
32CP92F1V2*81
32DP92F1V2*81
32EP92F1V2*81
32FP92F1V2*81
32GP92F1V2*81
32HP92F1V2*81
32IP92F1V2*81
32JP92F1V2*81
Disc
Amp
Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number
30
30
60
60
100
100
200
200
32CP92B1V2*81
32DP92B1V2*81
32EP92B1V2*81
32FP92B1V2*81
32GP92B1V2*81
32HP92B1V2*81
32IP92B1V2*81
32JP92B1V2*81
NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight
List Price $ Catalog Number
List Price $
32CP92N1V2*81
32DP92N1V2*81
32EP92N1V2*81
32FP92N1V2*81
32GP92N1V2*81
32HP92N1V2*81
32IP92N1V2*81
32JP92N1V2*81
Dual voltage coils not available in modified starters.
For conduit hubs and conversion instructions, see
page 8/88.
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Two Speed Heavy Duty Starters
Non-Fusible, Constant Horsepower with Ambient Compensated Bimetal Overload, Class 32
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. (6 Required)
Fuse clips see page 8/96.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/125.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
One Winding Consequent Pole, 3-Phase (Constant Horsepower)
Max Hp
Enclosure
200
230
Volts Volts
2
5
7 1⁄2
7 1⁄2
10
20
25
30
2
5
7 1⁄2
10
15
25
30
40
460
Volts
3
7 1⁄2
10
20
25
40
50
75
575
Volts
3
7 1⁄2
10
20
25
40
50
75
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight, Dust-tight
Corrosion Resistant
Contactor
Disc
Amp
NEMA Half Amp
Rating
Size
Size Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number
18
27
40
45
60
90
115
135
0
1
—
2
—
3
—
4
—
—
13⁄4
—
21⁄2
—
31⁄2
—
30
30
60
60
100
100
200
200
32CP92B2H2*81
32DP92B2H2*81
32EP92B2H2*81
32FP92B2H2*81
32GP92B2H2*81
32HP92B2H2*81
32IP92B2H2*81
32JP92B2H2*81
32CP92W2H2*81
32DP92W2H2*81
32EP92W2H2*81
32FP92W2H2*81
32GP92W2H2*81
32HP92W2H2*81
32IP92W2H2*81
32JP92W2H2*81
NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight
List Price $ Catalog Number
32CP92F2H2*81
32DP92F2H2*81
32EP92F2H2*81
32FP92F2H2*81
32GP92F2H2*81
32HP92F2H2*81
32IP92F2H2*81
32JP92F2H2*81
List Price $
32CP92N2H2*81
32DP92N2H2*81
32EP92N2H2*81
32FP92N2H2*81
32GP92N2H2*81
32HP92N2H2*81
32IP92N2H2*81
32JP92N2H2*81
Two Separate Windings, 3-Phase (Constant Horsepower)
Max Hp
Enclosure
200
230
Volts Volts
2
5
7 1⁄2
7 1⁄2
10
20
25
30
2
5
7 1⁄2
10
15
25
30
40
460
Volts
575
Volts
3
7 1⁄2
10
20
25
40
50
75
3
7 1⁄2
10
20
25
40
50
75
Contactor
Amp
NEMA Half
Rating
Size
Size
18
27
40
45
60
90
115
135
0
1
—
2
—
3
—
4
—
—
13⁄4
—
21⁄2
—
31⁄2
—
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.
Siemens Industry, Inc.
Industrial Controls Catalog
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight, Dust-tight
Corrosion Resistant
32CP92W1H2*81
32DP92W1H2*81
32EP92W1H2*81
32FP92W1H2*81
32GP92W1H2*81
32HP92W1H2*81
32IP92W1H2*81
32JP92W1H2*81
32CP92F1H2*81
32DP92F1H2*81
32EP92F1H2*81
32FP92F1H2*81
32GP92F1H2*81
32HP92F1H2*81
32IP92F1H2*81
32JP92F1H2*81
Disc
Amp
Rating Catalog Number List Price $ Catalog Number List Price $ Catalog Number
30
30
60
60
100
100
200
200
32CP92B1H2*81
32DP92B1H2*81
32EP92B1H2*81
32FP92B1H2*81
32GP92B1H2*81
32HP92B1H2*81
32IP92B1H2*81
32JP92B1H2*81
NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight
List Price $ Catalog Number
List Price $
32CP92N1H2*81
32DP92N1H2*81
32EP92N1H2*81
32FP92N1H2*81
32GP92N1H2*81
32HP92N1H2*81
32IP92N1H2*81
32JP92N1H2*81
Dual
voltage coils not available in modified starters.
conduit hubs and conversion instructions, see
page 8/88.
For
Product Category: NEMA
8/39
Combination Two Speed Heavy Duty Starters
MCP Type, Constant or Variable Torque with Solid State Overload, Class 32
Selection
Ordering Information
䊳
䊳
Coil Table
Replace the (*) with a letter from the
coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Replace the (†) with the letter that
corresponds to the correct low speed
FLA in the FLA table.
䊳
Field Modification Kits see page
8/82.
䊳
Factory Modifications see page 8/95.
䊳
Dimensions see page 8/125.
䊳
Wiring Diagrams see page 8/136.
䊳
Replacement Parts see page 8/157.
Low Speed FLA Table
60Hz Voltage
Letter
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
J
F
A
D
G
L
C
H
E
Size
FLA
OLR
Frame Size
†
0,1
0,1
0,1
0,1
0-13/4
2-3
2-3
21/2-4
0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200
A
A
A1
A1
A1
B
B
B
A
B
C
D
E
F
G
H
For other voltages and frequencies, see
Factory Modifications page 8/95.
One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
Motor
Circuit
200 230 460 575 NEMA Half Interruter
Volts Volts Volts Volts Size Size ETI Amps
1
3
⁄2
⁄4
11⁄2
2
0
— 3
2
2
5
5
0
— 10
3
3
—
—
0
— 25
1
3
⁄2
⁄4
11⁄2
11⁄2
1
— 3
2
2
5
5
1
— 10
3
3
10
10
1
— 25
71⁄2
71⁄2
—
—
1
— 30
—
—
15
15
—
13⁄4 40
10
15
25
25
2
— 50
15
20
30
30
—
21⁄2 100
25
30
50
50
3
— 100
30
40
75
75
—
31⁄2 125
40
50
100 100 4
— 150
Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B
Catalog
Number
32CUB†92B2V*
32CUC†92B2V*
32CUD†92B2V*
32DUB†92B2V*
32DUC†92B2V*
32DUD†92B2V*
32DUE†92B2V*
32EUE†92B2V*
32FUF†92B2V*
32GUG†92B2V*
32HUG†92B2V*
32IUH†92B2V*
32JUH†92B2V*
List
Price $
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog
Number
32CUB†92W2V*
32CUC†92W2V*
32CUD†92W2V*
32DUB†92W2V*
32DUC†92W2V*
32DUD†92W2V*
32DUE†92W2V*
32EUE†92W2V*
32FUF†92W2V*
32GUG†92W2V*
32HUG†92W2V*
32IUH†92W2V*
32JUH†92W2V*
Catalog
Number
32CUB†92F2V*
32CUC†92F2V*
32CUD†92F2V*
32DUB†92F2V*
32DUC†92F2V*
32DUD†92F2V*
32DUE†92F2V*
32EUE†92F2V*
32FUF†92F2V*
32GUG†92F2V*
32HUG†92F2V*
32IUH†92F2V*
32JUH†92F2V*
List
Price $
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
Catalog
Number
32CUB†92N2V*
32CUC†92N2V*
32CUD†92N2V*
32DUB†92N2V*
32DUC†92N2V*
32DUD†92N2V*
32DUE†92N2V*
32EUE†92N2V*
32FUF†92N2V*
32GUG†92N2V*
32HUG†92N2V*
32IUH†92N2V*
32JUH†92N2V*
List
Price $
Two Separate Windings, 3-Phase (Constant or Variable Torque)
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
Motor
Circuit
200 230 460 575 NEMA Half Interruter
Volts Volts Volts Volts Size Size ETI Amps
1
3
⁄2
⁄4
11⁄2
2
0
— 3
2
2
5
5
0
— 10
3
3
—
—
0
— 25
1
3
⁄2
⁄4
11⁄2
11⁄2
1
— 3
2
2
5
5
1
— 10
3
3
10
10
1
— 25
71⁄2
71⁄2
—
—
1
— 30
10
10
15
15
—
13⁄4 40
10
15
25
25
2
— 50
15
20
30
30
—
21⁄2 100
25
30
50
50
3
— 100
30
40
75
75
—
31⁄2 125
40
50
100 100 4
— 150
Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
Dual voltage coils not available in modified starters.
8/40
Frame
Size
A
A1
A1
A
A1
A1
A1
A1
B
B
B
B
B
Catalog
Number
32CUB†92B1V*
32CUC†92B1V*
32CUD†92B1V*
32DUB†92B1V*
32DUC†92B1V*
32DUD†92B1V*
32DUE†92B1V*
32EUE†92B1V*
32FUF†92B1V*
32GUG†92B1V*
32HUG†92B1V*
32IUH†92B1V*
32JUH†92B1V*
List
Price $
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog
Number
32CUB†92W1V*
32CUC†92W1V*
32CUD†92W1V*
32DUB†92W1V*
32DUC†92W1V*
32DUD†92W1V*
32DUE†92W1V*
32EUE†92W1V*
32FUF†92W1V*
32GUG†92W1V*
32HUG†92W1V*
32IUH†92W1V*
32JUH†92W1V*
Catalog
Number
32CUB†92F1V*
32CUC†92F1V*
32CUD†92F1V*
32DUB†92F1V*
32DUC†92F1V*
32DUD†92F1V*
32DUE†92F1V*
32EUE†92F1V*
32FUF†92F1V*
32GUG†92F1V*
32HUG†92F1V*
32IUH†92F1V*
32JUH†92F1V*
For
List
Price $
conduit hubs and conversion instructions, see
page 8/88.
motor FLA are unknown, select overload on the
basis that low speed FLA will be no greater than 50%
of high speed FLA.
If
Product Category: NEMA
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
Catalog
Number
32CUB†92N1V*
32CUC†92N1V*
32CUD†92N1V*
32DUB†92N1V*
32DUC†92N1V*
32DUD†92N1V*
32DUE†92N1V*
32EUE†92N1V*
32FUF†92N1V*
32GUG†92N1V*
32HUG†92N1V*
32IUH†92N1V*
32JUH†92N1V*
List
Price $
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Two Speed Heavy Duty Starters
MCP Type, Constant Horsepower with Solid State Overload, Class 32
Selection
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Ordering Information
Coil Table
Replace the (*) with a letter from
the coil table. Dual voltage coils are
wired on high voltage unless specified
on order.
Replace the (†) with the letter that
corresponds to the correct FLA in the
High/Low Speed FLA table.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/125.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.
60Hz Voltage
High/Low Speed FLA Table
Letter
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
For other voltages and
frequencies see Factory
Modifications page 8/95.
J
F
A
D
G
L
C
H
E
Size
FLA
OLR
Frame Size
†
0,1
0,1
0,1
0,1
0-13/4
2-3
2-3
21/2-4
0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200
A
A
A1
A1
A1
B
B
B
A
B
C
D
E
F
G
H
* First (†) for high speed, second (†)
for low speed. Use motor nameplate
to select FLA. If motor FLA are
unknown, select overload on the
bases that the low speed FLA will
be no greater than 50 % of high
speed FLA.
One Winding Consequent Pole, 3-Phase (Constant Horsepower)
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
Catalog
Number
Catalog
Number
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
Motor
Circuit
200 230 460 575 NEMA Half Interruter
Volts Volts Volts Volts Size Size ETI Amps
Amp
Range
Frame Catalog
Size Number
2
2
3
3
0
—
10
—
A or A1 32CU††92B2H*
32CU††92W2H*
32CU††92F2H*
32CU††92N2H*
5
5
71⁄2
71⁄2
1
—
25
—
A or A1 32DU††92B2H*
32DU††92W2H*
32DU††92F2H*
32DU††92N2H*
71⁄2
71⁄2
10
10
—
13⁄4
40
—
A1
32EU††92B2H*
32EU††92W2H*
32EU††92F2H*
32EU††92N2H*
71⁄2
10
20
20
2
—
50
—
B
32FU††92B2H*
32FU††92W2H*
32FU††92F2H*
32FU††92N2H*
10
15
25
25
—
21⁄2
100
—
B
32GU††92B2H*
32GU††92W2H*
32GU††92F2H*
32GU††92N2H*
20
25
40
40
3
—
100
—
B
32HU††92B2H*
32HU††92W2H*
32HU††92F2H*
32HU††92N2H*
25
30
50
50
—
31⁄2
125
—
B
32IU††92B2H*
32IU††92W2H*
32IU††92F2H*
32IU††92N2H*
30
40
75
75
4
—
150
—
B
32JU††92B2H*
32JU††92W2H*
32JU††92F2H*
32JU††92N2H*
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Corrosion Resistant
NEMA 12
NEMA 3/3R
Catalog
Number
Catalog
Number
List
Price $
List
Price $
List
Price $
Catalog
Number
List
Price $
Two Separate Windings, 3-Phase (Constant Horsepower)
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
Motor
Circuit
200 230 460 575 NEMA Half Interruter
Volts Volts Volts Volts Size Size ETI Amps
Amp
Range
Frame Catalog
Size Number
2
2
3
3
0
—
10
—
A or A1 32CU††92B1H*
32CU††92W1H*
32CU††92F1H*
32CU††92N1H*
5
5
71⁄2
71⁄2
1
—
25
—
A or A1 32DU††92B1H*
32DU††92W1H*
32DU††92F1H*
32DU††92N1H*
71⁄2
71⁄2
10
10
—
13⁄4
40
—
A1
32EU††92B1H*
32EU††92W1H*
32EU††92F1H*
32EU††92N1H*
71⁄2
10
20
20
2
—
50
—
B
32FU††92B1H*
32FU††92W1H*
32FU††92F1H*
32FU††92N1H*
10
15
25
25
—
21⁄2
100
—
B
32GU††92B1H*
32GU††92W1H*
32GU††92F1H*
32GU††92N1H*
20
25
40
40
3
—
100
—
B
32HU††92B1H*
32HU††92W1H*
32HU††92F1H*
32HU††92N1H*
25
30
50
50
—
31⁄2
125
—
B
32IU††92B1H*
32IU††92W1H*
32IU††92F1H*
32IU††92N1H*
30
40
75
75
4
—
150
—
B
32JU††92B1H*
32JU††92W1H*
32JU††92F1H*
32JU††92N1H*
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
Dual voltage coils not available in modified starters.
For conduit hubs and conversion instructions, see
page 8/88.
Siemens Industry, Inc.
Industrial Controls Catalog
List
Price $
First † for high speed, second † for low speed. Use
motor nameplate information to select FLA. If motor
FLA are unknown, select overload on the basis that
low speed FLA will be no greater than 50% of high
speed FLA.
Product Category: NEMA
List
Price $
List
Price $
Catalog
Number
List
Price $
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
8/41
Combination Two Speed Heavy Duty Starters
MCP Type, Constant or Variable Torque w/Ambient Compensated Bimetal Overload, Class 32
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. (6 Required)
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/125.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
One Winding Consequent Pole, 3-Phase (Constant or Variable Torque)
Max Hp
Enclosure
200
230 460
575 NEMA Half Motor Circuit
Volts Volts Volts Volts Size Size Interrupter ETI Amps
1
⁄2
1
3
1 1⁄2
1
3
7 1⁄2
—
10
—
10
10
15
—
25
30
40
1
⁄2
1
1
1
3
3
3
5
5
1
1 ⁄2
1
1
1
3
3
1
7 1⁄2
3
7 ⁄2
1
7 ⁄2 10
10
—
15
15
10
—
—
—
20
20
15
25
25
15
30
30
20
—
—
—
30
30
30
50
50
40
75
75
50
100 100
0
0
0
1
1
1
1
—
—
2
2
—
—
3
3
—
4
—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
—
—
31⁄2
—
3
10
25
3
10
25
30
40
50
40
50
50
100
50
100
125
150
NEMA 1
NEMA 4/4X Stainless
NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight, Dust-tight
Corrosion Resistant
Catalog Number List Price $ Catalog Number List Price $ Catalog Number
32CP92B2VA*81
32CP92B2VB*81
32CP92B2VC*81
32DP92B2VA*81
32DP92B2VB*81
32DP92B2VD*81
32DP92B2VE*81
32EP92B2VF*81
32EP92B2VG*81
32FP92B2VH*81
32FP92B2VJ*81
32GP92B2VK*81
32GP92B2VL*81
32HP92B2VM*81
32HP92B2VN*81
32IP92B2VP*81
32JP92B2VR*81
32CP92W2VA*81
32CP92W2VB*81
32CP92W2VC*81
32DP92W2VA*81
32DP92W2VB*81
32DP92W2VD*81
32DP92W2VE*81
32EP92W2VF*81
32EP92W2VG*81
32FP92W2VH*81
32FP92W2VJ*81
32GP92W2VK*81
32GP92W2VL*81
32HP92W2VM*81
32HP92W2VN*81
32IP92W2VP*81
32JP92W2VR*81
NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight
List Price $ Catalog Number
32CP92F2VA*81
32CP92F2VB*81
32CP92F2VC*81
32DP92F2VA*81
32DP92F2VB*81
32DP92F2VD*81
32DP92F2VE*81
32EP92F2VF*81
32EP92F2VG*81
32FP92F2VH*81
32FP92F2VJ*81
32GP92F2VK*81
32GP92F2VL*81
32HP92F2VM*81
32HP92F2VN*81
32IP92F2VP*81
32JP92F2VR*81
List Price $
32CP92N2VA*81
32CP92N2VB*81
32CP92N2VC*81
32DP92N2VA*81
32DP92N2VB*81
32DP92N2VD*81
32DP92N2VE*81
32EP92N2VF*81
32EP92N2VG*81
32FP92N2VH*81
32FP92N2VJ*81
32GP92N2VK*81
32GP92N2VL*81
32HP92N2VM*81
32HP92N2VN*81
32IP92N2VP*81
32JP92N2VR*81
Two Separate Windings, 3-Phase (Constant or Variable Torque)
Max Hp
Enclosure
200
230
460
575 NEMA Half Motor Circuit
Volts Volts Volts Volts Size Size Interrupter ETI Amps
1
⁄2
1
3
1
⁄2
1
3
7 1⁄2
—
10
—
10
10
15
—
25
30
40
1
⁄2
1
1
1
3
3
3
5
5
1
⁄2
1
1
1
3
3
7 1⁄2
3
7 1⁄2
7 1⁄2 10
10
—
15
15
10
—
—
—
20
20
15
25
25
15
30
30
20
—
—
—
30
30
30
50
50
40
75
75
50 100
100
0
0
0
1
1
1
1
—
—
2
2
—
—
3
3
—
4
—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
—
—
31⁄2
—
8/42
NEMA 4/4X Stainless NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight, Dust-tight
Corrosion Resistant
Catalog Number List Price $ Catalog Number List Price $ Catalog Number
3
10
25
3
10
25
30
40
50
40
50
50
100
50
100
125
150
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.
NEMA 1
32CP92B1VA*81
32CP92B1VB*81
32CP92B1VC*81
32DP92B1VA*81
32DP92B1VB*81
32DP92B1VD*81
32DP92B1VE*81
32EP92B1VF*81
32EP92B1VG*81
32FP92B1VH*81
32FP92B1VJ*81
32GP92B1VK*81
32GP92B1VL*81
32HP92B1VM*81
32HP92B1VN*81
32IP92B1VP*81
32JP92B1VR*81
32CP92W1VA*81
32CP92W1VB*81
32CP92W1VC*81
32DP92W1VA*81
32DP92W1VB*81
32DP92W1VD*81
32DP92W1VE*81
32EP92W1VF*81
32EP92W1VG*81
32FP92W1VH*81
32FP92W1VJ*81
32GP92W1VK*81
32GP92W1VL*81
32HP92W1VM*81
32HP92W1VN*81
32IP92W1VP*81
32JP92W1VR*81
32CP92F1VA*81
32CP92F1VB*81
32CP92F1VC*81
32DP92F1VA*81
32DP92F1VB*81
32DP92F1VD*81
32DP92F1VE*81
32EP92F1VF*81
32EP92F1VG*81
32FP92F1VH*81
32FP92F1VJ*81
32GP92F1VK*81
32GP92F1VL*81
32HP92F1VM*81
32HP92F1VN*81
32IP92F1VP*81
32JP92F1VR*81
NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight
List Price $ CatalogNumber
List Price $
32CP92N1VA*81
32CP92N1VB*81
32CP92N1VC*81
32DP92N1VA*81
32DP92N1VB*81
32DP92N1VD*81
32DP92N1VE*81
32EP92N1VF*81
32EP92N1VG*81
32FP92N1VH*81
32FP92N1VJ*81
32GP92N1VK*81
32GP92N1VL*81
32HP92N1VM*81
32HP92N1VN*81
32IP92N1VP*81
32JP92N1VR*81
Dual
voltage coils not available in modified starters.
conduit hubs and conversion instructions, see
page 8/88.
For
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Two Speed Heavy Duty Starters
MCP, Constant Horsepower w/Ambient Compensated Bimetal Overload, Class 32
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Heater elements see page 8/150. (6 Required)
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/125.
Wiring Diagrams see page 8/136.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
One Winding Consequent Pole, 3-Phase (Constant Horsepower)
Max Hp
Enclosure
200
230
460
575 NEMA Half
Volts Volts Volts Volts Size Size
1
⁄2
1 1⁄2
2
1
⁄2
1 1⁄2
3
5
—
7 1⁄2
—
7 1⁄2
—
10
20
25
30
1
⁄2
1 1⁄2
2
1
⁄2
1 1⁄2
3
5
—
7 1⁄2
7 1⁄2
10
—
15
25
30
40
1
3
—
1
3
7 1⁄2
—
10
—
15
20
30
30
40
50
75
1
3
—
1
3
7 1⁄2
—
10
—
20
—
30
40
—
50
75
0
0
0
1
1
1
1
—
—
2
2
—
3
3
—
4
—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
—
—
31⁄2
—
Motor Circuit
Interrupter ETI Amps
3
10
25
3
10
25
30
40
50
40
50
50
50
100
125
150
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight, Dust-tight
Corrosion Resistant
Catalog Number List Price $ Catalog Number List Price $ Catalog Number
32CP92B2HA*81
32CP92B2HB*81
32CP92B2HC*81
32DP92B2HA*81
32DP92B2HB*81
32DP92B2HD*81
32DP92B2HE*81
32EP92B2HF*81
32EP92B2HG*81
32FP92B2HH*81
32FP92B2HJ*81
32GP92B2HK*81
32HP92B2HM*81
32HP92B2HN*81
32IP92B2HP*81
32JP92B2HR*81
32CP92W2HA*81
32CP92W2HB*81
32CP92W2HC*81
32DP92W2HA*81
32DP92W2HB*81
32DP92W2HD*81
32DP92W2HE*81
32EP92W2HF*81
32EP92W2HG*81
32FP92W2HH*81
32FP92W2HJ*81
32GP92W2HK*81
32HP92W2HM*81
32HP92W2HN*81
32IP92W2HP*81
32JP92W2HR*81
NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight
List Price $ Catalog Number
32CP92F2HA*81
32CP92F2HB*81
32CP92F2HC*81
32DP92F2HA*81
32DP92F2HB*81
32DP92F2HD*81
32DP92F2HE*81
32EP92F2HF*81
32EP92F2HG*81
32FP92F2HH*81
32FP92F2HJ*81
32GP92F2HK*81
32HP92F2HM*81
32HP92F2HN*81
32IP92F2HP*81
32JP92F2HR*81
List Price $
32CP92N2HA*81
32CP92N2HB*81
32CP92N2HC*81
32DP92N2HA*81
32DP92N2HB*81
32DP92N2HD*81
32DP92N2HE*81
32EP92N2HF*81
32EP92N2HG*81
32FP92N2HH*81
32FP92N2HJ*81
32GP92N2HK*81
32HP92N2HM*81
32HP92N2HN*81
32IP92N2HP*81
32JP92N2HR*81
Two Separate Windings, 3-Phase (Constant Horsepower)
Max Hp
Enclosure
200
230
Volts Volts
1
⁄2
1 1⁄2
2
1
⁄2
1 1⁄2
3
5
—
7 1⁄2
—
7 1⁄2
—
10
20
25
30
1
⁄2
1 1⁄2
2
1
⁄2
1 1⁄2
3
5
—
7 1⁄2
7 1⁄2
10
—
15
25
30
40
460
575 NEMA Half
Volts Volts Size Size
1
3
—
1
3
7 1⁄2
—
10
—
15
20
30
30
40
50
75
1
3
—
1
3
7 1⁄2
—
10
—
20
—
30
40
—
50
75
0
0
0
1
1
1
1
—
—
2
2
—
3
3
—
4
—
—
—
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
—
—
31⁄2
—
Motor Circuit
Interrupter ETI Amps
3
10
25
3
10
25
30
40
50
40
50
50
50
100
125
150
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.
Siemens Industry, Inc.
Industrial Controls Catalog
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight, Dust-tight
Corrosion Resistant
Catalog Number List Price $ Catalog Number List Price $ Catalog Number
32CP92B1HA*81
32CP92B1HB*81
32CP92B1HC*81
32DP92B1HA*81
32DP92B1HB*81
32DP92B1HD*81
32DP92B1HE*81
32EP92B1HF*81
32EP92B1HG*81
32FP92B1HH*81
32FP92B1HJ*81
32GP92B1HK*81
32HP92B1HM*81
32HP92B1HN*81
32IP92B1HP*81
32JP92B1HR*81
32CP92W1HA*81
32CP92W1HB*81
32CP92W1HC*81
32DP92W1HA*81
32DP92W1HB*81
32DP92W1HD*81
32DP92W1HE*81
32EP92W1HF*81
32EP92W1HG*81
32FP92W1HH*81
32FP92W1HJ*81
32GP92W1HK*81
32HP92W1HM*81
32HP92W1HN*81
32IP92W1HP*81
32JP92W1HR*81
32CP92F1HA*81
32CP92F1HB*81
32CP92F1HC*81
32DP92F1HA*81
32DP92F1HB*81
32DP92F1HD*81
32DP92F1HE*81
32EP92F1HF*81
32EP92F1HG*81
32FP92F1HH*81
32FP92F1HJ*81
32GP92F1HK*81
32HP92F1HM*81
32HP92F1HN*81
32IP92F1HP*81
32JP92F1HR*81
NEMA 12, NEMA 3/3R
NEMA 4 Painted
Industrial Use
Weatherproof
Watertight, Dust-tight
List Price $ Catalog Number
List Price $
32CP92N1HA*81
32CP92N1HB*81
32CP92N1HC*81
32DP92N1HA*81
32DP92N1HB*81
32DP92N1HD*81
32DP92N1HE*81
32EP92N1HF*81
32EP92N1HG*81
32FP92N1HH*81
32FP92N1HJ*81
32GP92N1HK*81
32HP92N1HM*81
32HP92N1HN*81
32IP92N1HP*81
32JP92N1HR*81
Dual
voltage coils not available in modified starters.
conduit hubs and conversion instructions, see
page 8/88.
For
Product Category: NEMA
8/43
Heavy Duty Contactors
3-Phase, Class 40
Selection
Ordering Information
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/107 open and 8/116 enclosed.
Wiring Diagrams see page 8/142.
Replacement Parts see page 8/157.
䊳
䊳
䊳
䊳
䊳
䊳
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
Open Type
NEMA 1
NEMA 4/4X
Stainless
General Purpose
Catalog
Number
1 1⁄2
3
7 1⁄2
10
10
15
25
30
40
75
150
—
—
40BP32A*
40CP32A*
40DP32A*
40EP32A*
40FP32A*
40GP32A*
40HP32A*
40IP32A*
40JG32A*
40LP32A*
40MP32A*
40NH32A*
40PH32A*
2
5
10
15
25
30
50
75
100
200
400
600
900
2
5
10
15
25
30
50
75
100
200
400
600
900
9
18
27
40
45
60
90
115
135
270
540
810
1215
00
0
1
—
2
—
3
—
4
5
6
7
8
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—
NEMA 12
NEMA 3/3R
NEMA 7 & 9
NEMA 3 & 4
Watertight, Dust-tight Watertight, Dust-tight Div1 and Div 2
Industrial Use
Corrosion Resistant
Corrosion Resistant
Class I Groups C & D Weatherproof
304 Stainless Steel
Class II Groups E,F&G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Contactor
200
230
460
575 Amp
NEMA Half
Volts Volts Volts Volts Rating Size
Size
1 1⁄2
3
7 1⁄2
10
15
20
30
40
50
100
200
300
450
NEMA 4X
Fiberglass
List
Catalog
Price $ Number
List
Price $
40BP32B*
40CP32B*
40DP32B*
40EP32B*
40FP32B*
40GP32B*
40HP32B*
40IP32B*
40JG32B*
40LP32B*
40MP32B*
40NH32B*
40PH32B*
Catalog
Number
List
Catalog
Price $ Number
Use Size 0 —
40CP32W*
40DP32W*
40EP32W*
40FP32W*
40GP32W*
40HP32W*
40IP32W*
40JG32W*
40LP32E*
40MP32E*
40NH32E*
40PH32E*
List
Catalog
Price $ Number
Use Size 0
40CP32F*
40DP32F*
40EP32F*
40FP32F*
40GP32F*
40HP32F*
40IP32F*
40JG32F*
—
—
—
—
—
—
—
—
—
List
Catalog
Price $ Number
Use Size 0
40CP32H*
40DP32H*
40EP32H*
40FP32H*
40GP32H*
40HP32H*
40IP32H*
40JG32H*
40LP32H*
—
—
—
—
—
—
—
List
Price $
Use Size 0 —
40CP320*
40DP320*
40EP320*
40FP320*
40GP320*
40HP320*
40IP320*
40JG320*
40LP320*
40MP320*
40NH320*
40PH320*
Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
200
Volts
230
Volts
1 1⁄2
3
7 1⁄2
10
10
15
25
30
40
1 1⁄2
3
7 1⁄2
10
15
20
30
40
50
460
Volts
575
Volts
2
5
10
15
25
30
50
75
100
2
5
10
15
25
30
50
75
100
Contactor
Amp
NEMA Half
Range
Size
Size
9
18
27
40
45
60
90
115
135
00
0
1
—
2
—
3
—
4
—
—
—
13/4
—
21/2
—
31/2
—
Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.
Dual voltage coils not available in size 5-8 starters.
For conduit hubs and conversion instructions, see
page 8/88.
NEMA 1
NEMA 4/4X Stainless
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Catalog Number
List Price $
40BP82B*
40CP82B*
40DP82B*
40EP82B*
40FP82B*
40GP82B*
40HP82B*
40IP82B*
40JG82B*
Catalog Number
Use Size 0
40CP82W*
40DP82W*
40EP82W*
40FP82W*
40GP82W*
40HP82W*
40IP82W*
40JG82W*
Enclosure is NEMA
Only available
Type 4 (painted steel).
F coil 100-250V AC 50/60Hz, or DC
H coil 150-500V AC 50/60Hz, or DC
Only available
F coil100-250V AC 50/60Hz, or DC
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Industrial Use
Weatherproof
List Price $ Catalog Number
—
Use Size 0
40CP82H*
40DP82H*
40EP82H*
40FP82H*
40GP82H*
40HP82H*
40IP82H*
40JG82H*
Product Category: NEMA
—
Use Size 0
40CP820*
40DP820*
40EP820*
40FP820*
40GP820*
40HP820*
40IP820*
40JG820*
—
Standard Auxiliary Contacts
Type
All FVNR
Starters &
Contactors
Lugs
8/44
List Price $ Catalog Number List Price $
Size (3rd Character)
Configuration
B Thru E
1N.O.
Internal / External
Internal
F Thru J
1N.O.
External
L Thru M
2N.O., 2N.C.
External
N Thru P
1N.O., 1N.C.
External
are not included, refer to page 8/86.
Siemens Industry, Inc.
Industrial Controls Catalog
Heavy Duty Contactors
Single Phase, 4-Pole & Vacuum, Class 40
Selection
Ordering Information
Coil Table
Replace the (*) with a letter from the coil table.
Dual voltage coils are wired on high voltage unless
specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/107 open and 8/116
enclosed.
Wiring Diagrams see page 8/142.
Replacement Parts see page 8/157.
䊳
䊳
䊳
䊳
䊳
䊳
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Open Type & Standard Width Enclosure, Single Phase, 2-Pole
Max Hp
Enclosure
Open Type
NEMA 1
General Purposes
208/
115
230
Volts Volts
1
⁄3
1
2
3
3
5
7 1⁄3
—
—
1
2
3
5
7 1⁄2
10
15
—
—
NEMA 4/4X
Stainless
NEMA 4X
Fiberglass
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Watertight, Dust-tight
Corrosion Resistant
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosure
Indoor/Outdoor Use
Industrial Use
Weatherproof
Contactor
Amp
NEMA
Rating Size
Half
Size
Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No
9
18
27
35
45
60
90
115
135
—
—
—
—
—
21⁄2
—
31⁄2
—
40BP12A*
40CP12A*
40DP12A*
40EP12A*
40FP12A*
40GP12A*
40HP12A*
40IP12A*
40JG12A*
00
0
1
1P
2
—
3
—
4
40BP12B*
40CP12B*
40DP12B*
40EP12B*
40FP12B*
40GP12B*
40HP12B*
40IP12B*
40JG12B*
Use Size 0
40CP12W*
40DP12W*
40EP12W*
40FP12W*
40GP12W*
40HP12W*
40IP12W*
40JG12W*
—
List Price $
Catalog No
—
Use Size 0
40CP12H*
40DP12H*
40EP12H*
40FP12H*
40GP12H*
40HP12H*
40IP12H*
40JG12H*
Use Size 0
40CP12F*
40DP12F*
40EP12F*
40FP12F*
40GP12F*
40HP12F*
40IP12F*
40JG12F*
List Price $ Catalog No List Price $
—
Use Size 0
40CP120*
40DP120*
40EP120*
40FP120*
40GP120*
40HP120*
40IP120*
40JG120*
—
Open Type & Standard Width Enclosure, 4-Pole
Max Hp
Enclosure
Open Type
NEMA 1
General Purpose
NEMA 4/4X
Stainless
NEMA 4X
Fiberglass
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight, Dust-tight
Corrosion Resistant
Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosure
Indoor/Outdoor Use
Industrial Use
Weatherproof
Contactor
200 230 460
575 Amp NEMA Half
Volts Volts Volts Volts Rating Size
Size Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $
1
⁄3
2
3
5
1 1⁄2
3
7 1⁄2
10
2
5
10
15
2
5
10
15
9
18
27
40
00
0
1
—
—
—
—
13⁄4
40BP22A*
40CP22A*
40DP22A*
40EP22A*
40BP22B*
40CP22B*
40DP22B*
40EP22B*
Use Size 0
40CP22W*
40DP22W*
40EP22W*
—
Use Size 0
40CP22F*
40DP22F*
40EP22F*
—
Use Size 0
40CP22H*
40DP22H*
40EP22H*
—
Use Size 0
40CP220*
40DP220*
40EP220*
—
Vacuum Contactors, 3-Phase, 3-Pole
Max Hp
200V
230V
460V
575V
40
75
150
50
100
200
100
200
400
100
200
400
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.
Dual
voltage coils not available for vacuum contactors.
Refer to Page 8/95 for a complete list of available coil
voltages.
Siemens Industry, Inc.
Industrial Controls Catalog
For
Contactor
Amp
Rating
135
270
540
conduit hubs and conversion instructions, see page
8/88.
order single phase contactor in an extra wide enclosure, order the enclosure kit from Page 16-91 and the
open style contactor as separate items.
To
Product Category: NEMA
NEMA
Size
4
5
6
Open Type
Catalog Number
List Price $
40JV32A*
40LV32A*
40MV32A*
Coils
D, F, or G will be wired for incoming voltage.
J coil will be wired for separate source. Coils E, H,
and L do not apply to single phase starters.
1 NO Auxiliary.
8/45
Reversing Heavy Duty Contactors
Class 43
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see pages 8/108 open and 8/121 enclosed.
Wiring Diagrams see page 8/142.
Replacement Parts see page 8/157.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 8/95.
Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
Open Type
NEMA 1
General Purpose
Contactor
200 230 460 575 Amp NEMA Half Catalog
Volts Volts Volts Volts Rating Size Size Number
1
⁄2
3
7 1⁄2
10
10
15
25
30
40
75
100
—
—
1
⁄2
3
7 1⁄2
10
15
20
30
40
50
100
200
300
450
2
5
10
15
25
30
50
75
100
200
400
600
900
2
5
10
15
25
30
50
75
100
200
400
600
900
9
18
27
40
45
60
90
115
135
270
540
810
1215
00
0
1
—
2
—
3
—
4
5
6
7
8
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—
List
Catalog
Price $ Number
43BP32A*
43CP32A*
43DP32A*
43EP32A*
43FP32A*
43GP32A*
43HP32A*
43IP32A*
43JG32A*
43LP32A*
43MP32A*
43NH32A*
43PH32A*
NEMA 4/4X Stainless NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight NEMA 3 & 4
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
List
Catalog
Price $ Number
43BP32B*
43CP32B*
43DP32B*
43EP32B*
43FP32B*
43GP32B*
43HP32B*
43IP32B*
43JG32B*
43LP32B*
43MP32B*
43NH32B*
—
—
List
Price $
Use Size 0
43CP32W*
43DP32W*
43EP32W*
43FP32W*
43GP32W*
43HP32W*
43IP32W*
43JG32W*
43LP32E*
43MP32E*
43NH32E*
—
—
—
Corrosion Resistant
Catalog
Number
Use Size 0
43CP32F*
43DP32F*
43EP32F*
43FP32F*
43GP32F*
43HP32F*
43IP32F*
43JG32F*
—
—
—
—
List
Catalog
Price $ Number
—
—
—
—
—
NEMA 12
NEMA 3/3R
Div 1 and Div 2
Industrial Use
Class I Groups C & D
Weatherproof
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
List
Price $
Use Size 0
43CP32H*
43DP32H*
43EP32H*
43FP32H*
43GP32H*
43HP32H*
43IP32H*
43JG32H*
—
—
—
—
—
—
—
—
—
Catalog
Number
Use Size 0
43CP320*
43DP320*
43EP320*
43FP320*
43GP320*
43HP320*
43IP320*
43JG320*
43LP320*
43MP320*
43NH320*
—
List
Price $
—
—
Open Type & Standard Width Enclosure, Single Phase, 3-Wire, 2-Pole
Max Hp
Enclosure
Open Type
Cont208/ actor
115 230 Amp NEMA
Volts Volts Rating Size Catalog No
1 1⁄3
1
2
3
1
2
3
5
9
18
27
35
00
0
1
1P
43BP12A*
43CP12A*
43DP12A*
43EP12A*
NEMA 1
NEMA 4/4X Stainless NEMA 4X Fiberglass
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
List Price $ Catalog No List Price $ Catalog No
43BP12B*
43CP12B*
43DP12B*
43EP12B*
Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.
Dual voltage coils not available in size 5–8 starters.
For conduit hubs and conversion instructions, see
page 8/88.
8/46
Use Size 0
43CP12W*
43DP12W*
43EP12W*
List Price $
—
Watertight, Dust-tight
Corrosion Resistant
Catalog No
List Price $
Use Size 0
43CP12F*
43DP12F*
43EP12F*
Enclosure
Coils D, F,
is NEMA Type 4 (painted steel).
or G will be wired for incoming voltage. J
coil will be wired for separate source. Coils E, H, and
L do not apply to single phase starters.
Only available
F coil 100-250V AC 50/60Hz, or DC
H coil 150-500V AC 50/60Hz, or DC
Product Category: NEMA
—
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3R
Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Industrial Use
Weatherproof
Catalog No
List Price $
Use Size 0
43CP12H*
43DP12H*
43EP12H*
—
Catalog No
Use Size 0
43CP120*
43DP120*
43EP120*
List Price $
—
Only
available
F coil 100-250V AC 50/60Hz, or DC
contacts
43B-43E 4th pole built-in
43F-43J 2 NO & 2 NC
Auxiliary
Siemens Industry, Inc.
Industrial Controls Catalog
Heavy Duty Control
Catalog Numbering System
General
Class
48 — Overload
No. of Poles
Size
A — Frame A
B — Frame B
Model
3 — 3 Phase
1 — Single Phase
T — ESP200
Trip Curve
00 — Class 5, 10, 20 or 30 Selectable
Current Range
A
B
C
D
E
F
G
H
J
K
L
M
N
—
—
—
—
—
—
—
—
—
—
—
—
—
0.25–1
Reset
0.75–3.4
3–12
S — Selectable (Man/Auto)
5.5–22
10–40
13–52
25–100
50–200
100–300 (3.33-10 current range with 300:5 CT and 1 loop with frame A1 (3-12A)-device)
133–400 (3.33-10 current range with 400:5 CT and 1 loop with frame A1 (3-12A)-device)
200–600 (3.33-10 current range with 600:5 CT and 1 loop with frame A1 (3-12A)-device)
250–750 (3.33-10 current range with 750:5 CT and 1 loop with frame A1 (3-12A)-device)
400–1200 (3.33-10.17 currant range with 1200:5 CT and 1 loop with frame A1 (3-12A)-device)
Trip Curve
Class
Model
958 — Overload
Amp Range
A — 958
B — ESP200
Type
S — Selectable (Man/Auto)
E — 10–40
G — 25–100
H — 50–200
No. of Poles
3 — 3 phase
Trip Curve
Class
958L
Model
— Overload
Amp Range
D
E
F
G
H
Ranges
—
—
—
—
—
5.5–22
10–40
13–52
25–100
50–200
A — 958L
B — ESP200
Type
S — Selectable (Man/Auto)
No. of Poles
3 — 3 phase
available in Single or 3-phase.
Siemens Industry, Inc.
Industrial Controls Catalog
8/47
Overload Relays
Solid State ESP200, Class 48, 958 and 958L
General
Features
Benefits
▪ Trip Classes - 5, 10, 20, or 30 Selectable by DIP-switches
▪ Field changeable reduces time and inventory. Suitable for
light, normal and heavy starting conditions
▪ Phase Loss Protection - Trips in less than 3 Seconds
▪ Protects motor burn out and minimizes motor heating up
▪ Phase Unbalance - Trips based on Trip Class selected
▪ Minimizes temperature rise of the motor on a asymmetrical
three-phase-system
▪ Ground Fault - Trips 60% of Motor Current
▪ Provides optimum system protection of motors against
high-resistance short-circuits or ground faults due to moisture,
condensation, damage of insulation or any other reason
▪ Trip Indicator - Visible
▪ Save time, faster to identify overload Trip
▪ Ambient Insensitive
▪ Prevents nuisance tripping
▪ No Heaters Required
▪ Saves cost and eliminates time for installation of heaters
▪ Self-Powered - No outside source required
▪ Reduce cost for external power supply
▪ FLA dial with wide Adjustment - 4:1 ratio
▪ Provides wide range, reduces inventory
▪ Self Protected in short circuit condition (when used with
proper fuses or motor starter protector)
▪ Unlike bimetal overloads, this eliminates replacement of the
overload heaters after short circuit
▪ Test Button - Tests Electronics
▪ Tests the complete electronic functions including the trip
mechanism. Increases up time
▪ Thermal Memory
▪ Prevents re-starting motor when it is still hot
▪ Conformally coated circuit board
▪ Resists against environmental conditions
▪ 1 NO and 1NC Contacts Standard. B600, R300
▪ Makes it easier for user to wire local contacts
▪ Operating Temperature: -25 °C - 65 °C
▪ Wide operating temperature range prevents nuisance tripping
with temperature changes
▪ Repeat Accuracy <1%.
▪ For more precise settings and reduced nuisance tripping
▪ Removable Terminal Block
▪ Terminal Block can be removed without removing wires.
Saves time for replacements
▪ Automatic reset
▪ Auto. Reset is 3 minutes after tripping, allowing motor to
cool down before re-start. If Manual Reset is selected,
overload can be reset immediately
▪ Remote reset
▪ As an alternative to the mechanical RESET options, an
electrical remote RESET can be used by applying 24 V DC
to terminals A3 and A4
▪ DIN Rail Mounted
▪ Reduces installation time
▪ Touch - Safe Terminals
▪ Protects against accidental touching of live circuits
▪ UL listed CSA certified
▪ Third party approval standard
8/48
Siemens Industry, Inc.
Industrial Controls Catalog
Overload Relays
Solid State ESP200, Class 48, 958, 958L and Bimetal
General
ESP200 Solid State Overload
Applications
ESP200 Solid State Overloads
Designed for a wide variety of applications. The field selectable Trip Class 5,
10, 20 or 30 can easily be set by 2 DIP
switches. This eliminates the guess
factor of an application requirements
and provides reduced inventory for
multiple applications. The inherent
benefits of the ESP200 ultimately
results in cost savings for the user.
ESP200 has a 4:1 current adjustment
range with a fine adjustment dial
labeled in full load amps. The heaterless overload minimizes the heat
trapped in the enclosures, reduces cost
for ventilation or cooling. Easily accessible Reset button, provides visible and
audible indications to ensure the tripped
overload is ready to re-start.
Designed to replace thermal, or ESP100
overload relays for any application. It
has the same dimensions and footprint
of the ESP100 overload relays. It can
be directly coupled to the contactors
or remotely mounted. In addition to
the NEMA contactor applications, it
also can be used with other types of
controllers for applications requiring DP
or IEC contactors. As a retrofit for other
brands, it is used with a plate available
for retrofitting competitive products.
958 or 958L Solid State Overload
958 ESP200 Special Use Solid State
Overloads
This overload is specifically designed for
special applications, to provide excellent
protection of hermetically sealed and
artificially cooled motors that require
ambient insensitive and quick trip
response times. Combined with a series
lockout relay, it provides unsurpassed
protection for hermetically sealed
compressor motors in air conditioning
applications. The combination of high trip
speed, current adjustment, and ease of
installation makes it suitable for these
applications. The trip curves are
customized to provide proper overload
protection for these loads without
causing nuisance tripping.
It has selectable manual or automatic
reset mode, and provides ground fault
selection to protect equipment from
damage in case of a fault.
958L ESP200 Oil Field Solid State
Overloads
Specifically designed for the oil market
and the cycling loads experienced with
these types of pumping applications.
These overload relays provide protection
for standard motors, oil well pump
motors, multi-torque connections, and
ultra-high slip motors.
Rotors can be damaged in less than 15
seconds during motor stall conditions
if electrical power is not removed. To
prevent damage during motor stall, the
958L solid state overload removes the
power in 7 seconds at 250% lock rotor
current. Therefore, the motor casing
and the rotor will be protected from
being damage saving the user money
and time.
Siemens Industry, Inc.
Industrial Controls Catalog
Ambient Compensated Bimetal
Single Phase and Three Phase
▪ Ambient Compensated Bimetal
Overloads
—Automatic or manual reset adjustment
—A manual test button is provided to
test the operation of the 3-pole
overload relay control contacts
—앐15% nominal trip current adjustment
—Accept either standard Class 20 or
Quick Trip (NEMA Class 10) heater
elements without any other
changes or adjustments
—Available with a normally open contact
for an alarm circuit (SPDT) up to 60A
—Compensated bimetal overload relays
provide a constant trip time in ambient temperatures from –20°F to
ѿ170°F for a given heater rating
▪ UL Listed File #E22655 or Component
Recognized
▪ CSA Certified File #LR6535
Ambient Compensated Bimetal
Overloads
These thermal type overload relays are
used to protect motors from excessive
heat resulting from sustained motor
overloads, rapid motor cycling and
stalled rotor conditions. Although these
devices function based on thermal
principles they are designed to
compensate for the ambient air
temperature surrounding the overload.
This helps prevent the occurrence of nuisance tripping when there are high surrounding ambient temperatures.
The percentage of overload determines
the length of time required to open the
circuit.
8/49
Overload Relays
Solid State Class 48, ESP200 and 3RB20
Selection
Ordering Information
䊳
䊳
䊳
䊳
For CT’s see Accessories page 8/51.
Dimensions see page 8/109.
To retrofit or direct mount to a contactor, order 49ASMP1, 2, or 3 separately. See
Retrofit Plates below.
For remote mounting of frame size A order 49ASMS1 terminals separately, see page 8/86.
3-Phase, 48ATC3S00
Solid State—Class 48
Current Adjustment Range
Phase
Frame Size
Catalog Number
MRPD/MLFB
0.25–1
0.75–3.4
3–12
5.5–22
10–40
13–52
25–100
50–200
100–300
133–400
200–600
250–750
400–1220
0.25–1
0.75–3.4
3–12
5.5–22
3
3
3
3
3
3
3
3
3
3
3
3
3
1
1
1
1
"A"
"A"
"A1"
"A1"
"A1"
"B"
"B"
"B"
"A1"
"A1"
"A1"
"A1"
"A1"
"A"
"A"
"A1"
"A1"
48ATA3S00
48ATB3S00
48ATC3S00
48ATD3S00
48ATE3S00
48BTF3S00
48BTG3S00
48BTH3S00
48ATJ3S00
48ATK3S00
48ATL3S00
48ATM3S00
48ATN3S00
48ATA1S00
48ATB1S00
48ATC1S00
48ATD1S00
3UB81134AB2
3UB81134BB2
3UB81234CW2
3UB81234DW2
3UB81234EW2
3UB81334FW2
3UB81334GW2
3UB81334HW2
3UB81234JW2
3UB81234KW2
3UB81234LW2
3UB81234MW2
3UB81234NW2
3UB88134AB2
3UB88134BB2
3UB88234CW2
3UB88234DW2
List Price $
Solid State—3RB206, 3-Phase, Manual/Auto Reset
For Contactor Size
Setting Range Amps
Class 10
Catalog Number
5
6
55 - 250
160 - 630
3RB2066-1GC2
3RB2066-1MC2
List Price $
Class 20
Catalog Number
List Price $
3RB2066-2GC2
3RB2066-2MC2
Retrofit Plates for Contactors, Class 48
Replacement for Starter Sizes
ESP200 Overload Frame Size
Retrofit Plate Suffix
Plate Kit Separate
Size 00–13⁄4
Size 2, 21⁄2
Size 3, 31⁄2
Size 4
A or A1
B
B
B
1P
2P
3P
4P
49ASMP1
49ASMP2
49ASMP3
49ASMP3
Price Adder $
Ambient Compensated Bimetal—Open Type Class 48 Single Phase, 3-Phase (Panel Mount Only)
Poles
1
3
Amp
Rating
Auxiliary Contacts
25
60
100
180
30
30
60
60
100
180
1 NC
1 NC
1 NC
1 NC
1 NC
1 NO/NC
1 NC
1 NO/NC
3 NC
3 NC
Contact
Rating
5A (B600)
&
5A (P300)
10A (A600)
&
5A (P300)
5A (B600) & 5A (P300)
Catalog Number
48DA18AA4
48GA18AA4
48HA18AA4
48JA18AA4
48DC38AA4
48DC39AA4
48GC38AA4
48GC39AA4
48HA38AA4
48JA38AA4
To
Requires
use of 600:5 Current Transformers–3 of
Requires
97CT008.
97CT009.
Requires
Requires
use of 1200:5 Current Transformers–3 of
Requires
determine frame size of replacement solid state
overload, refer to retrofit plates table above.
use of 300:5 Current Transformers–3 of
97CT005.
Product Category: IEC.
8/50
97CT012.
Overload
List
Price $
use of 750:5 Current Transformers–3 of
use of 400:5 Current Transformers–3 of
97CT006.
has busbar connections.
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Overload Relays
Special Use Solid State Overloads, Class 958 and 958L
Selection
Ordering Information
Current Transformers
Dimensions see page 8/109.
䊳
Rating
Class 958, 958L
Catalog No.
150:5
97CT002
200:5
97CT003
250:5
97CT004
300:5
97CT005
400:5
97CT006
600:5
97CT008
750:5
97CT009
1200:5
97CT012
List Price $
Solid State—Class 958 and 958L
Current Adjustment Range
Phase
Frame Size
Catalog Number
MRPD/MLFB
10–40
25–100
50–200
5.5–22
10–40
13–52
25–100
50–200
3
3
3
3
3
3
3
3
"A1"
"B"
"B"
"A1"
"A1"
"B"
"B"
"B"
958EB3SA
958GB3SA
958HB3SA
958LDB3SA
958LEB3SA
958LFB3SA
958LGB3SA
958LHB3SA
3UB85235EW2
3UB85335GW2
3UB85335HW2
3UB85236DW2
3UB85236EW2
3UB85336FW2
3UB85336GW2
3UB85336HW2
Time - Current - Characteristics
CLASS 958, 958L
Time - Current - Characteristics
CLASS 48
List Price $
Trip - curve depending on unbalance
CLASS 20
1000
1000
1000
Trip time in seconds
Trip time in seconds
Trip time in seconds
500
100
50
phase unbalance = 0%, CLASS 20
phase unbalance = 20%, CLASS 20
phase unbalance = 50%, CLASS 20
phase unbalance = 80%, CLASS 20
phase unbalance = 100%, CLASS 20
500
500
100
100
50
50
CLASS 30 - cold start
CLASS 20 - cold start
10
10
10
CLASS 958L
CLASS 10 - cold start
5
5
5
CLASS 5 - cold start
CLASS 5 - warm start
CLASS 958
1
1
0.6
1
1.5
2
multiple of full load amp (FLA)
5
multiple of full load amp (FLA)
10
0.6
1
1.5
2
5
10
1
multiple of full load amp (FLA)
multiple of full load amp (FLA)
0.6
1
1.5
2
10
5
multiple of full load amp (FLA)
multiple of full load amp (FLA)
Temperature
rating 앥25° to 쎵60°C.
Siemens Industry, Inc.
Industrial Controls Catalog
Product Category: NEMA
8/51
Duplex Heavy Duty Controllers
General
Class 83
Class 84
Features
▪ Heavy Duty NEMA Starters
▪ Solid State or Thermal Overload
Relays
▪ Fusible or MCP
▪ Heavy Duty Disconnect Handle
▪ Flexibility with Field Modifications
▪ Alternator Transfer on De-energization
▪ UL Listed for Outdoor Use and
Service Equipment
▪ UL Listed file #E14900 (class 83); file
#E185287 (class 84)
▪ CSA certified file #LR 6535 (class 83
& 84)
Application
Duplex pump controls are designed to
perform one or both of two distinct
functions: duplexing and alternation. The
duplexing function provides capacity for
system peaking or above normal demand
without having the full motor capacity
spinning at all times. It also provides
standby capacity for use when one of
the motors or pumps is disabled. The
duplexing function is also referred to as
lead/lag or main/standby. When two
pumps or compressors are controlled by
a duplex controller, they are started in
sequence as necessary to attain preset
values of pressure, flow or liquid level.
8/52
Two field devices such as pressure
switches or float switches provide
electrical signals to the duplex controller.
One remote device is set to initiate the
starting of the lead motor. This motor is
rated to handle normal system demand.
The second motor is usually the same
rating and is referred to as the lag motor.
It is only energized when the system
demand is greater than the capacity of
the lead motor. The lag motor is started
when the second remote device is
signalling for more output than the
lead motor can produce.
The alternation function reverses the lead
and lag mode for the two motors in a
duplex system. Upon alternation the first
motor as described above becomes the
lag motor and the second motor
assumes the lead function. The
alternation is usually programmed to
occur at any time both pumps come to
rest. The alternation function equalizes
wear on the two machines and extends
the life of seals and bearings.
Enclosure Types
Duplex controllers are available in
NEMA 1, 12/3/3R, 4 (painted) and
4/4X (stainless) enclosures.
Enclosures protect personnel from
contact with live parts and depending
upon the construction, protect the
control in varying degrees from physical
damage and harmful atmospheres. All
enclosures are supplied with corrosion
resistant finishes.
Heavy Duty Starters
These Duplex controllers use the same
starters described in the heavy duty
starter section of this catalog.
Siemens Type ETI Circuit Breaker
The ETI circuit breaker is a device
designed specifically for application
in motor circuits. The ETI is a magnetic
only protective device designed to
provide protection against short
circuit current.
The instantaneous-only type ETI circuit
breaker employs adjustable magnetic
trip settings to allow broader application
ranges and a higher degree of motor
short circuit protection.
Features
Two control transformers may be
provided for low voltage control to
safeguard personnel from high voltage.
One transformer is required for each
starter to provide independent control
circuits.
A Hand-Off-Auto selector switch for each
starter may be mounted in the enclosure
door or furnished separately for remote
control. Test push buttons or pilot lights
may also be installed on the enclosure.
Solid-state or Ambient Compensated
Bimetal Overload Relays are supplied as
standard.
Heavy Duty Disconnect Switches
The disconnect switch that goes the
distance in durability, performance and
reliability has the following advantages:
▪ Visible blades for the highest level
of safety
▪ Double break switching action to
reduce arcing, increase lifetime and
eliminate the “electric hinge”
▪ More rugged positive action switch
▪ Oversized lugs are standard
▪ Line side shield to help guard
personnel from contact with live parts
▪ Higher horsepower rating for
design E high efficiency motors
▪ UL listed for IIsco, Burndy and T&B
crimp type lugs
▪ The 200A switch accepts up to 300
MCM versus 250 MCM wire size
Its rugged construction - with a high
fault withstand rating of 100kA at 600
VAC when fused with class R rated
fuses - meets the most stringent
industry standards set forth by the
automotive, petro-chemical, and pulp
and paper industries. UL recognized and
CSA certified, our disconnect switches
are available either non-fusible or fusible
with class R and class J fuse clips.
Siemens Industry, Inc.
Industrial Controls Catalog
Duplex Heavy Duty Controllers
Non-Combination, Class 83
Selection
Ordering Information
Coil Table
Standard coil voltage supplied will be 120V, separate control.
For non-alternator styles (see factory modifications) change
the 9th character using the coil table.
Heater elements for bimetal overloads see page 8/150 (6-Required).
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/127.
Wiring Diagrams see page 8/143.
Replacement Parts see page 8/157.
60Hz Voltage
Letter
24 Separate Control
120 Separate Control
200–208
220–240
277
440–480
550–600
J
F
D
G
L
H
E
Non-Combination (with Solid-State Overload)
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
200
Volts
230
Volts
460
Volts
575
Volts
NEMA
Size
Half
Size
Amp
Range
Frame
Size
Catalog
Number
List
Price $
NEMA 4/4X Stainless
NEMA 4 Painted
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Catalog
Number
Catalog
Number
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
List
Price $
Catalog
Number
⁄6
1
⁄6
1
⁄3
1
⁄2
0
—
0.25–1
A
83CUA92BF
83CUA92WF
83CUA92EF
83CUA920F
1
⁄2
3
⁄4
11⁄2
2
0
—
0.75–3.4
A
83CUB92BF
83CUB92WF
83CUB92EF
83CUB920F
2
2
5
5
0
—
3–12
A1
83CUC92BF
83CUC92WF
83CUC92EF
83CUC920F
3
3
—
—
0
—
5.5–22
A1
83CUD92BF
83CUD92WF
83CUD92EF
83CUD920F
⁄6
1
1
⁄2
1
⁄6
1
⁄3
1
⁄2
1
—
0.25–1
A
83DUA92BF
83DUA92WF
83DUA92EF
83DUA920F
3
⁄4
11⁄2
2
1
—
0.75–3.4
A
83DUB92BF
83DUB92WF
83DUB92EF
83DUB920F
2
2
5
5
1
—
3–12
A1
83DUC92BF
83DUC92WF
83DUC92EF
83DUC920F
3
3
10
10
1
—
5.5–22
A1
83DUD92BF
83DUD92WF
83DUD92EF
83DUD920F
71⁄2
71⁄2
—
—
1
—
10–40
A1
83DUE92BF
83DUE92WF
83DUE92EF
83DUE920F
10
10
15
15
—
13⁄4
10–40
A1
83EUE92BF
83EUE92WF
83EUE92EF
83EUE920F
10
15
25
25
2
—
13–52
B
83FUF92BF
83FUF92WF
83FUF92EF
83FUF920F
15
20
30
30
—
21⁄2
25–100
B
83GUG92BF
83GUG92WF
83GUG92EF
83GUG920F
25
30
50
50
3
—
25–100
B
83HUG92BF
83HUG92WF
83HUG92EF
83HUG920F
30
40
75
75
—
31⁄2
50–200
B
83IUH92BF
83IUH92WF
83IUH92EF
83IUH920F
40
50
100
100
4
—
50–200
B
83JUH92BF
83JUH92WF
83JUH92EF
83JUH920F
1
List
Price $
Non-Combination (with Ambient Compensated Bimetal Overload)
Max Hp
Enclosure
200
Volts
230
Volts
3
71⁄2
10
10
15
25
30
40
3
71⁄2
10
15
20
30
40
50
460
Volts
5
10
15
25
30
50
75
100
575
Volts
5
10
15
25
30
50
75
100
NEMA Half
Size
Size
0
1
—
—
—
13⁄4
2
—
—
21⁄2
3
—
—
31⁄2
4
—
NEMA 1
NEMA 4/4X Stainless
NEMA 4 Painted
NEMA 12/3R
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight
Dust-tight
Industrial Use
Weatherproof
Catalog Number
Catalog Number
Catalog Number
Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.
Siemens Industry, Inc.
Industrial Controls Catalog
List Price $
83CP92BF81
83DP92BF81
83EP92BF81
83FP92BF81
83GP92BF81
83HP92BF81
83IP92BF81
83JP92BF81
List Price $
83CP92WF81
83DP92WF81
83EP92WF81
83FP92WF81
83GP92WF81
83HP92WF81
83IP920W81
83JP92WF81
NEMA
12 is field convertible to NEMA 3/3R. For conduit
hubs and conversion instructions, see page 8/88.
Not available on standard alternator style ('92' in the
catalog number).
Product Category: NEMA
List Price $
83CP92EF81
83DP92EF81
83EP92EF81
83FP92EF81
83GP92EF81
83HP92EF81
83IP92EF81
83JP92EF81
Catalog Number
List Price $
83CP920F81
83DP920F81
83EP920F81
83FP920F81
83GP920F81
83HP920F81
83IP920F81
83JP920F81
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
8/53
Duplex Heavy Duty Controllers
Combination Disconnect [Fusible & Non-Fusible], Class 84
Selection
䊳
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Ordering Information
Coil Table
Standard coil voltage supplied will be 120V, separate control.
For non-alternator styles (see factory modifications) change
the 10th character using the coil table.
Heater elements for bimetal overloads see page 8/150 (6-Required).
For factory installed fusible disconnect, see page 8/96.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/127.
Wiring Diagrams see page 8/143.
Replacement Parts see page 8/157.
60Hz Voltage
Letter
24 Separate Control
120 Separate Control
200–208
220–240
277
440–480
550–600
J
F
D
G
L
H
E
Two Disconnect Switches with Solid-State Overload
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
200 230 460 575 NEMA
Volts Volts Volts Volts Size
Half Amp
Size Range
Disc.
Frame Amp
Catalog
Size
Range Number
List
Price $
NEMA 4/4X Stainless
NEMA 4 Painted
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Catalog
Number
Catalog
Number
List
Price $
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
Catalog
Number
⁄6
1
⁄6
1
⁄3
1
⁄2
0
—
0.25–1
A
30
84CUA92BDF
84CUA92WDF
84CUA92EDF
84CUA920DF
1
⁄2
3
⁄4
11⁄2
2
0
—
0.75–3.4
A
30
84CUB92BDF
84CUB92WDF
84CUB92EDF
84CUB920DF
2
2
5
5
0
—
3–12
A1
30
84CUC92BDF
84CUC92WDF
84CUC92EDF
84CUC920DF
3
3
—
—
0
—
5.5–22
A1
30
84CUD92BDF
84CUD92WDF
84CUD92EDF
84CUD920DF
⁄6
1
1
⁄2
1
⁄6
1
⁄3
1
⁄2
1
—
0.25–1
A
30
84DUA92BDF
84DUA92WDF
84DUA92EDF
84DUA920DF
3
⁄4
11⁄2
2
1
—
0.75–3.4
A
30
84DUB92BDF
84DUB92WDF
84DUB92EDF
84DUB920DF
2
2
5
5
1
—
3–12
A1
30
84DUC92BDF
84DUC92WDF
84DUC92EDF
84DUC920DF
3
3
10
10
1
—
5.5–22
A1
30
84DUD92BDF
84DUD92WDF
84DUD92EDF
84DUD920DF
71⁄2
71⁄2
—
—
1
—
10–40
A1
30
84DUE92BDF
84DUE92WDF
84DUE92EDF
84DUE920DF
10
10
15
15
—
13⁄4
10–40
A1
60
84EUE92BDF
84EUE92WDF
84EUE92EDF
84EUE920DF
10
15
25
25
2
—
13–52
B
60
84FUF92BDF
84FUF92WDF
84FUF92EDF
84FUF920DF
15
20
30
30
—
21⁄2
25–100
B
100
84GUG92BDF
84GUG92WDF
84GUG92EDF
84GUG920DF
20
25
50
50
3
—
25–100
B
100
84HUG92BDF
84HUG92WDF
84HUG92EDF
84HUG920DF
30
40
75
75
—
31⁄2
50–200
B
200
84IUH92BDF
84IUH92WDF
84IUH92EDF
84IUH920DF
40
50
100
100
4
—
50–200
B
200
84JUH92BDF
84JUH92WDF
84JUH92EDF
84JUH920DF
1
List
Price $
Two Disconnect Switches with Ambient Compensated Bimetal Overload
Max Hp
Enclosure
200
Volts
230
Volts
3
71⁄2
10
10
15
20
30
40
3
71⁄2
10
15
20
25
40
50
460
Volts
5
10
15
25
30
50
75
100
575
Volts
5
10
15
25
30
50
75
100
NEMA Half
Size
Size
0
1
—
—
—
13⁄4
2
—
—
21⁄2
3
—
—
31⁄2
4
—
NEMA 4/4X Stainless
NEMA 4 Painted
NEMA 12/3R
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight
Dust-tight
Industrial Use
Weatherproof
Catalog Number
Catalog Number
Disc
Amp
Range Catalog Number
30
30
60
60
100
100
200
200
Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.
8/54
NEMA 1
List Price $
List Price $
List Price $
Catalog Number
84CP92BDF81
84DP92BDF81
84EP92BDF81
84FP92BDF81
84CP92WDF81
84DP92WDF81
84EP92WDF81
84FP92WDF81
84CP92EDF81
84DP92EDF81
84EP92EDF81
84FP92EDF81
84CP920DF81
84DP920DF81
84EP920DF81
84FP920DF81
84GP92BDF81
84HP92BDF81
84IP92BDF81
84JP92BDF81
84GP92WDF81
84HP92WDF81
84IP92WDF81
84JP92WDF81
84GP92EDF81
84HP92EDF81
84IP92EDF81
84JP92EDF81
84GP920DF81
84HP920DF81
84IP920DF81
84JP920DF81
NEMA
12 is field convertible to NEMA 3/3R. For conduit
hubs and conversion instructions, see page 8/88.
Not available on standard alternator style
('92' in the catalog number).
Product Category: NEMA
List Price $
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
Siemens Industry, Inc.
Industrial Controls Catalog
Duplex Heavy Duty Controllers
Combination Circuit Breaker, Class 84
Selection
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Ordering Information
Coil Table
Standard coil voltage supplied will be 120V, separate control.
For non-alternator styles (see factory modifications) change
the 10th character using the coil table.
Heater elements for bimetal overloads see page 8/150 (6-Required).
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/127.
Wiring Diagrams see page 8/143.
Replacement Parts see page 8/157.
60Hz Voltage
Letter
24 Separate Control
120 Separate Control
200–208
220–240
277
440–480
550–600
J
F
D
G
L
H
E
2 Motor Circuit Protectors (with Solid-State Overload)
Max Hp
Enclosure
NEMA 1
Overload
General Purpose
200 230 460 575 NEMA Half Amp
Volts Volts Volts Volts Size
Size Range
Motor
Circuit
Frame Interrupter Catalog
Size
ETI
Number
1
⁄6
⁄2
2
3
1
1
3
1
⁄6
⁄2
2
3
71⁄2
1
1
3
List
Price $
NEMA 4/4X Stainless
NEMA 4 Painted
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Watertight, Dust-tight
Catalog
Number
Catalog
Number
NEMA 12
NEMA 3/3R
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
List
Price $
Catalog
Number
⁄6
⁄4
2
3
1
⁄3
11⁄2
5
—
1
⁄2
2
5
—
0
0
0
0
—
—
—
—
0.25–1
0.75–3.4
3–12
5.5–22
A
A
A1
A1
3
3
10
25
84CUA92BMF
84CUB92BMF
84CUC92BMF
84CUD92BMF
84CUA92WMF
84CUB92WMF
84CUC92WMF
84CUD92WMF
84CUA92EMF
84CUB92EMF
84CUC92EMF
84CUD92EMF
84CUA920MF
84CUB920MF
84CUC920MF
84CUD920MF
⁄6
⁄4
2
3
71⁄2
1
⁄3
11⁄2
5
10
—
1
⁄2
2
5
10
—
1
1
1
1
1
—
—
—
—
—
0.25–1
0.75–3.4
3–12
5.5–22
10–40
A
A
A1
A1
A1
3
3
10
25
30
84DUA92BMF
84DUB92BMF
84DUC92BMF
84DUD92BMF
84DUE92BMF
84DUA92WMF
84DUB92WMF
84DUC92WMF
84DUD92WMF
84DUE92WMF
84DUA92EMF
84DUB92EMF
84DUC92EMF
84DUD92EMF
84DUE92EMF
84DUA920MF
84DUB920MF
84DUC920MF
84DUD920MF
84DUE920MF
—
—
15
15
—
13⁄4
10–40
A1
40
84EUE92BMF
84EUE92WMF
84EUE92EMF
84EUE920MF
10
15
25
25
2
—
13–52
B
50
84FUF92BMF
84FUF92WMF
84FUF92EMF
84FUF920MF
15
20
30
30
—
21⁄2
25–100
B
100
84GUG92BMF
84GUG92WMF
84GUG92EMF
84GUG920MF
20
25
50
50
3
—
25–100
B
100
84HUG92BMF
84HUG92WMF
84HUG92EMF
84HUG920MF
30
40
75
75
—
31⁄2
50–200
B
125
84IUH92BMF
84IUH92WMF
84IUH92EMF
84IUH920MF
40
50
100
100
4
—
50–200
B
150
84JUH92BMF
84JUH92WMF
84JUH92EMF
84JUH920MF
List
Price $
2 Motor Circuit Protectors (with Ambient Compensated Bimetal Overload)
Max Hp
Enclosure
200 230
460
575
NEMA Half
Volts Volts Volts Volts Size
Size
⁄
2
3
1⁄2
2
3
71⁄2
—
10
—
10
—
15
—
20
30
40
12
⁄
34
2
3
3⁄4
2
3
71⁄2
—
10
—
15
—
20
—
25
40
50
11⁄2
5
—
11⁄2
5
10
—
15
—
15
25
30
—
30
50
75
100
2
5
—
2
5
10
—
15
—
20
25
30
—
40
50
75
100
0
0
0
1
1
1
1
—
—
—
—
—
—
—
—
—
13⁄4
13⁄4
2
2
—
—
—
—
21⁄2
21⁄2
3
3
—
—
—
31⁄2
4
—
Motor
Circuit
Interrupter
ETI
3
10
25
3
10
25
30
40
50
40
50
50
100
50
100
125
150
Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.
Siemens Industry, Inc.
Industrial Controls Catalog
NEMA 1
NEMA 4/4X Stainless
NEMA 4 Painted
NEMA 12/3R
General Purpose
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steel
Watertight
Dust-tight
Industrial Use
Weatherproof
Catalog
Number
84CPB92BMF81
84CPD92BMF81
84CPE92BMF81
84DPB92BMF81
84DPD92BMF81
84DPE92BMF81
84DPF92BMF81
84EPF92BMF81
84EPG92BMF81
84FPF92BMF81
84FPH92BMF81
84GPH92BMF81
84GPJ92BMF81
84HPJ92BMF81
84HPK92BMF81
84IPL92BMF81
84JPM92BMF81
List
Price $
Catalog
Number
84CPB92WMF81
84CPD92WMF81
84CPE92WMF81
84DPB92WMF81
84DPD92WMF81
84DPE92WMF81
84DPF92WMF81
84EPF92WMF81
84EPG92WMF81
84FPF92WMF81
84FPH92WMF81
84GPH92WMF81
84GPJ92WMF81
84HPJ92WMF81
84HPK92WMF81
84IPL92WMF81
84JPM92WMF81
NEMA
List
Price $
12 is field convertible to NEMA 3/3R. For conduit
hubs and conversion instructions, see page 8/88.
Not available on standard alternator style
('92' in the catalog number).
Product Category: NEMA
Catalog
Number
84CPB92EMF81
84CPD92EMF81
84CPE92EMF81
84DPB92EMF81
84DPD92EMF81
84DPE92EMF81
84DPF92EMF81
84EPF92EMF81
84EPG92EMF81
84FPF92EMF81
84FPH92EMF81
84GPH92EMF81
84GPJ92EMF81
84HPJ92EMF81
84HPK92EMF81
84IPL92EMF81
84JPM92EMF81
List
Price $
Catalog
Number
List
Price $
84CPB920MF81
84CPD920MF81
84CPE920MF81
84DPB920MF81
84DPD920MF81
84DPE920MF81
84DPF920MF81
84EPF920MF81
84EPG920MF81
84FPF920MF81
84FPH920MF81
84GPH920MF81
84GPJ920MF81
84HPJ920MF81
84HPK920MF81
84IPL920MF81
84JPM920MF81
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then
8/55
Pump Control Panels
Irrigation Pump Panel with Solid State Overload, Class 81
General
䊳
䊳
䊳
䊳
䊳
䊳
Ordering Information
Coil Table
Replace the (*) with a letter from the coil table.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/128.
Wiring Diagrams see page 8/145.
Replacement parts refer to instruction sheet SFIS-81010-1207.
60Hz Voltage
Letter
24
110–220
200–208
208–240
277
440–480
J
F
D
G
L
H
Siemens introduces its new Class 81 Irrigation Pump Panel. This
newest addition to the already extensive line of Siemens pump
panels was designed specifically for the agricultural market. It is
well suited for irrigation and similar pumping applications and is
built to withstand the harsh elements of the outdoors.
Typical applications include:
• Crop irrigation
• Sprinklers, misters and soakers
• Watering for livestock and other dairy applications
• Ground dewatering for excavation and construction sites
Features and Benefits
• Heavy-duty horsepower rated contactors sized 1/2 – 40hp to
provide reliable motor control and protection expected in the
most demanding applications
• Type 3R enclosure fabricated with galvannealed steel versusconventional cold rolled steel for superior corrosion resistance
• Rugged 30mm H-O-A switch and Start push button, which are
standard features, meet Type 3, 4, 12, and 13 specifications
and are oil and dust tight for durability
• Pre-punched opening with cover plate for convenient field
installation of a conduit hub should top entry be required
• Full gasketed door to ensure a dust tight and water tight seal
• Mounting flanges at top and bottom of enclosure for easy
mounting on poles or flat surfaces using keyhole slots
• Door is removable for ease of installation and maintenance
• Factory and field modifications for custom applications
• UL rated as service entrance equipment
• UL listed
• Pre-drilled mounted holes for MotorSaver®
Circuit Breaker
Max Hp
200
Volts
1⁄2
11⁄2
2
3
3
5
5
71⁄2
10
10
20
230
Volts
1⁄2
2
2
3
5
5
71⁄2
10
10
15
20
480
Volts
1
3
5
71⁄2
10
10
15
20
25
30
40
Contactor Amp Rating
25
25
25
25
30
30
40
50
60
60
90
Overload Amp Range
0.75-3
2.5-10
2.5-10
9-18
9-18
13-27
13-27
22-45
22-45
30-60
45-90
Breaker Amp Size
15
15
20
25
30
40
50
60
70
90
125
Catalog
Number
81AFB6MA*
81AFD6MA*
81AFD6MB*
81AFE6MC*
81BFE6MD*
81BFF6ME*
81CFF6MF*
81DFH6MG*
81EFH6MH*
81EFJ6MK*
81GEK6MN*
Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.
8/56
Siemens Industry, Inc.
Industrial Controls Catalog
Pump Control Panels
Class 87, 88
General
Features
Application
Features
▪ Fully Gasketed NEMA 3R Rainproof
Enclosures
▪ 100,000 Amp Interrupting Capacity
with Class R Fuses
▪ Heavy Duty NEMA Starters
▪ Solid State or Ambient Compensated
Bimetal Overload Relays
▪ Heavy Duty Disconnect Handle
▪ Available in Reduced Voltage Versions
▪ Bold Pilot Legend on Front
▪ Generous Accessory Space
▪ Copper Grounding Lug For Three
#6 Wires
▪ UL Listed for Outdoor Use and
Service Equipment File #E185287
Heavy duty pump control panels are
designed to withstand the most
demanding environments. Typical
applications include irrigation, agriculture,
petrochemical, wastewater treatment
and wherever motor control is
challenged by harsh elements.
Rugged pump control panels utilized
cold forming “tox” process. They are
more rainproof, sleet and ice
resistant than in the past.
Installation is easy. Panels are factory
wired to provide flexible control and
protect against short circuits and
overloads. Ample space is provided
for field modifications and installation
of accessories.
The pump control panels feature a full
sized removable auxiliary panel for the
mounting of accessories. The fusible
version features fuse clips for full sized
RK5 or compact class J fuses and
accessory mounting space for the
most commonly used accessories.
Class 87 pump panels become jockey
pump panels with the addition of a
pressure switch. The jockey pump’s
primary function is to maintain water
pressure at a preset level and thus
compensate for possible shortage of
water in the pumping system. When the
water pressure drops below the preset
level, the pressure switch energizes the
starter which in turn activates the jockey
pump. The water pressure is then
brought back up to the desired level. This
insures the maintenance of proper water
pressure at all times.
Specified by Fortune 500 companies,
Siemens NEMA starters offer
prolonged service under severe duty
conditions. NEMA rated, these starters
utilize large silver cadmium oxide
contacts and wide copper heat sinks
to ensure rapid heat dissipation and
maximum electrical life.
Siemens Industry, Inc.
Industrial Controls Catalog
ESP200 solid state overload relay
Refer to the section on Class 48 overload relays for features and benefits.
Pump panels are factory set at trip Class
10.
The ambient compensated bimetal
overload relays are designed to
parallel thermal characteristics of typical
pump motors. They prevent nuisance
trips that may result from operation of
the control in a higher ambient temperature than that at the pump. These relays
are trip-free, tamperproof and can be set
to reset automatically or manually.
HOA and Start Pushbutton
Every pump panel comes with an HOA
and a start pushbutton.
Half Size Starters
Siemens motor matched starters feature
all the rugged performance characteristics
of our NEMA rated starter sizes, but are
fractionally sized to more closely match
your exact motor rating. As a result,
significant economic savings are made
possible without sacrificing the reliability
you expect from a heavy duty starter.
These additional starter sizes have the
reserve capacity to handle occasional
plugging and jogging without de-rating
the device.
Siemens motor matched can save hundreds,
even thousands of dollars per project.
Siemens motor matched starters comply
with NEMA, UL and CSA standards.
8/57
Pump Control Panels
Class 87, 88
General
Panels are predrilled for easy repositioning
of the fuse trailer block to accommodate
250 and 600 volt fuses and full sized RK
or compact J fuses. Circuit breakers are
also available.
Heavy Duty Fusible
Disconnect Switch
The disconnect switch has the following
advantages:
▪ Visible blades for the highest
level of safety
▪ Double Break Switching Action
to reduce arcing, increase lifetime
and eliminate the “electric hinge”
▪ Oversized lugs are standard
▪ Line side shield to help guard
personnel from contact with live parts
Motor Circuit Protector
The motor circuit protector provides fast,
accurate fault clearing that will minimize
damage to the motor and control
apparatus and protect branch circuit
conductors. Continuous current ratings
and adjustable trip ranges meet NEC
requirements for full load and locked
rotor currents. The adjustable
instantaneous trip point can be set
precisely to assure fault protection
and eliminate nuisance tripping.
Removable Door
Enclosure door may be lifted off to make
wiring easier.
Mounting Flanges
Convenient flanges at top and bottom
of the enclosure provide easy mounting.
They fit pole or flat surfaces using
keyhole slots.
Quarter Turn Latches
Quarter turns are utilized to secure the
door.
Wind Catches
A wind catch is provided to prevent the
door from slamming shut (or open) due
to high wind conditions.
8/58
Safety Disconnect Handle
Up to three padlocks can be used to lock
the disconnect in the OFF position.
Maintenance work can be performed
without hazard to personnel.
External Reset
The overload relay may be quickly reset
by means of a button on the front of the
enclosure.
Bold Pilot Legend
Provides positive indication of the
selector switch position for use to
stop the pump motor.
Ground Lugs
Insures proper connecting of ground
wires and lightning arresters.
UL Listed
Assures proper construction throughout
control panel.
Reduced Voltage
Available in part winding, wye delta and
auto transformer types, these controls
may be necessary where the power
company limits the amount of current
drawn from its lines, or where starting
torque must be reduced.
Fully gasketed NEMA 3/12 weatherproof enclosures are supplied with
Class 88 reduced voltage starters.
Part Winding Starters apply starting
current in timed steps to minimize
voltage fluctuations.
Auto Transformer Starters maintain
a closed circuit during transition and
eliminate voltage or current surges.
They draw less current than part winding
starters and are well suited for starting
motors over 20 Hp.
Wye Delta starters and motors are
used in areas where the power supply is
inadequate to supply full starting current
without objectionable voltage drop or for
applications where low starting torque is
required. Centrifugal pumps and similar
apparatus requiring a low starting torque
are typical applications. Both ends of all
three windings of the wye delta motor
are brought out so that they may be
accessible for reconnecting from wye
to delta.
Auxiliary Equipment
Pilot Lights are easily installed on the
enclosure. Oil Tight and Heavy Duty, they
meet NEMA A600 requirements.
Lightning Arresters protect the control panel from lightning induced surges.
Undervoltage and Phase Sensing
Relays protect the pump against low
voltage, voltage imbalance, loss of phase
and phase reversal.
Anti-Backspin Timers prevent the
motor from starting during motor/shaft
backspin.
The TOX Box
Siemens uses the TOX process to
manufacture the enclosures for the
pump panels.
Advantages of the TOX process:
▪ Joints are 50-70% stronger
▪ Since the TOX process compresses
the metal at the joint, it does not
leave the high stresses in the metal
▪ Increased corrosion resistance.
The protective layer on the metal is
not damaged in the process, but
instead flows with the material
Class 87 NEMA Vacuum Starter
Pump Control Panels
The Siemens vacuum starter pump
controllers are designed for the harshest
environments. Typical environments
include chemical, petrochemical, waste
water treatment and mining.
Contaminations present in these
severe environments are detrimental
to conventional air-break contacts
decreasing their life expectancy and
reliability. The Siemens vacuum starter
pump controllers are well suited for
these environments because the
contacts are contained in hermetically
sealed contact tubes. This prevents
contaminates in the atmosphere from
affecting the operation of the contacts.
Additionally, neither arcs nor arcing
gases are produced which dramatically
increases the electrical endurance of
the contacts.
Siemens Industry, Inc.
Industrial Controls Catalog
Pump Control Panels
Standard Pump Panel with Solid State Overload, Class 87
Selection
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Ordering Information
Coil Table
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/128.
Wiring Diagrams see page 8/145.
Replacement Parts see page 8/157.
Sizes 1-4 will be supplied standard with a 240/480 volt coil. To
change the coil voltage, change the 8th character in the catalog
number to the letter shown in the coil table.
Sizes 5 & 6 will be supplied standard with a 480 volt coil. To change
the coil voltage, change the 8th character in the catalog number to
the letter shown in the coil table.
60Hz Voltage
Letter
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
220–240/440–480
277
440–480
550–600
J
F
A
D
G
C
L
H
E
Fusible Disconnect
Max Hp
200
Volts
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2
3
71⁄2
71⁄2
10
10
10
15
15
20
25
30
40
75
230
Volts
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2
3
71⁄2
71⁄2
10
15
15
20
20
25
30
40
50
100
460
Volts
1
5
71⁄2
71⁄2
15
15
15
25
30
30
50
50
75
100
200
250
—
—
—
—
—
—
—
—
—
—
—
—
—
—
575
Volts
1
5
10
10
15
15
25
25
30
30
50
50
75
100
200
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
NEMA
Size
1
1
1
1
—
—
2
2
—
—
3
3
—
4
5
6
1
1
1
1
—
2
2
—
—
3
3
—
4
5
Overload
Amp
Range
0.75–3.4
3–12
5.5–22
5.5–22
10–40
10–40
13–52
13–52
13–52
13–52
25–100
25–100
50–200
50–200
55–250
160–630
3–12
5.5–22
10–40
10–40
10–40
13–52
13–52
25–100
25–100
25–100
25–100
50–200
50–200
55–250
Half
Size
—
—
—
—
13⁄4
13⁄4
—
—
21⁄2
21⁄2
—
—
31⁄2
—
—
—
—
—
—
—
13⁄4
—
—
21⁄2
21⁄2
—
—
31⁄2
—
—
Disc.
Amp
Range
30
30
30
60
30
60
60
100
60
100
100
200
200
200
400
600
30
30
30
60
60
60
100
60
100
100
200
200
200
400
Frame
Size
A
A1
A1
A1
A1
A1
B
B
B
B
B
B
B
B
—
—
A1
A1
A1
A1
A1
B
B
B
B
B
B
B
B
—
Fuse
Clip
Amp / Volts
30A/600V
30A/600V
30A/600V
60A/600V
30A/600V
60A/600V
60A/600V
100A/600V
60A/600V
100A/600V
100A/600V
200A/600V
200A/600V
200A/600V
400A/600V
600A/600V
30A/250V
30A/250V
30A/250V
60A/250V
60A/250V
60A/250V
100A/250V
60A/250V
100A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
Catalog
Number
87DUB6FC
87DUC6FC
87DUD6FC
87DUD60C
87EUE6FC
87EUE60C
87FUF6FC
87FUF60C
87GUG6FC
87GUG60C
87HUG6FC
87HUG60C
87IUH6FC
87JUH6FC
87LPU6FH
87MSW6FH
87DUC6LC
87DUD6LC
87DUE6LC
87DUE6PC
87EUE6LC
87FUF6LC
87FUF6PC
87GUG6LC
87GUG6PC
87HUG6LC
87HUG6PC
87IUH6LC
87JUH6LC
87LPU6LG
List
Price $
Circuit Breaker
Max Hp
200
Volts
1
⁄2
2
3
71⁄2
—
10
15
25
30
40
50
75
100
150
230
Volts
1
⁄2
2
3
71⁄2
—
15
20
30
40
50
75
100
125
200
460
Volts
1
5
71⁄2
10
15
25
30
50
75
100
150
200
250
400
575
Volts
1
5
10
—
15
25
30
50
75
100
200
200
300
400
NEMA
Size
1
1
1
1
—
2
—
3
—
4
5
5
6
6
Note: All starter sizes carry one maximum Hp rating (per
the National Electric Code).
Siemens Industry, Inc.
Industrial Controls Catalog
Half
Size
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—
Overload
Amp
Range
0.75–3.4
3–12
5.5–22
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
160–630
Frame
Size
A
A1
A1
A1
A1
B
B
B
B
B
—
—
—
—
Not available on Size 5 and
For an overload amp range
Motor Circuit
Interrupter
ETI Amps
3
10
25
30
40
50
100
100
125
150
250
400
400
600
larger.
of 0.25-1A, change the
5th character from a ‘B’ to an ‘A’.
Product Category: NEMA
Catalog
Number
87DUB6MC
87DUC6MC
87DUD6MC
87DUE6MC
87EUE6MC
87FUF6MC
87GUG6MC
87HUG6MC
87IUH6MC
87JUH6MC
87LPT6MH
87LPU6MH
87MSW6MH
87MSX6MH
List
Price $
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009.
Continue to order enclosed starters with the ESP100
OLR until then.
8/59
Pump Control Panels
Pump Panel with Ambient Compensated Bimetal Overload, Class 87
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
䊳
䊳
Coil Table
Heater elements for bimetal overloads see page 8/150 (6-Required).
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/128.
Wiring Diagrams see page 8/145.
Replacement Parts see page 8/157.
Sizes 1-4 will be supplied standard with a 230/480 volt coil. To change the coil
voltage, change the 8th character in the catalog number to the letter shown in
the coil table.
Sizes 5 & 6 will be supplied standard with a 480 volt coil. To change the coil
voltage, change the 8th character in the catalog number to the letter shown
in the coil table.
60Hz Voltage
Letter
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
220–240/440–480
277
440–480
550–600
J
F
A
D
G
C
L
H
E
Fusible Disconnect
Max HP
200V
230V
460V
575V
NEMA Size
Half Size
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
10
10
15
15
25
25
30
30
50
50
75
100
10
10
15
15
25
25
30
30
50
50
75
100
1
1
—
—
—
—
13⁄4
13⁄4
2
2
—
—
—
—
21⁄2
21⁄2
3
3
—
—
—
31⁄2
71⁄2
71⁄2
10
10
10
15
25
25
30
40
71⁄2
71⁄2
10
15
15
20
30
30
40
50
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
4
1
1
—
—
—
—
13⁄4
2
2
—
—
—
21⁄2
3
3
—
—
—
31⁄2
4
—
Disc
Amp Rating
30
60
30
60
60
100
60
100
100
200
200
200
30
60
60
60
100
100
100
200
200
200
Fuse Clip
Amps/Volts
Catalog Number
30A/600V
60A/600V
30A/600V
60A/600V
60A/600V
100A/600V
60A/600V
100A/600V
100A/600V
200A/600V
200A/600V
200A/600V
30A/250V
60A/250V
60A/250V
60A/250V
100A/250V
100A/250V
100A/250V
200A/250V
200A/250V
200A/250V
87DAE6FC
87DAE60C
87EAF6FC
87EAF60C
87FAJ6FC
87FAJ60C
87GAK6FC
87GAK60C
87HAN6FC
87HAN60C
87IAP6FC
87JAR6FC
87DAE6LC
87DAE6PC
87EAG6LC
87FAJ6LC
87FAJ6PC
87GAL6LC
87HAN6LC
87HAN6PC
87IAP6LC
87JAR6LC
Catalog Number
List Price $
List Price $
Circuit Breaker
Max HP
200V
230V
460V
575V
NEMA Size
Half Size
⁄
1
3
71⁄2
71⁄2
10
12
⁄
1
3
71⁄2
71⁄2
10
1
3
71⁄2
10
15
1
3
71⁄2
10
15
1
1
1
1
—
—
—
—
—
—
—
—
13⁄4
13⁄4
15
25
30
20
25
30
2
2
—
—
—
—
—
—
21⁄2
21⁄2
50
75
100
50
75
100
12
—
—
10
15
—
—
15
25
30
40
20
30
40
50
3
—
—
31⁄2
4
—
Note: Hp’s shown above are based on the overload
amp range for the FLA’s (per the National Electric
Code) of typical industrial motors. All starter sizes
carry one maximum Hp rating.
8/60
Not
Motor Circuit
Interrupter
ETI Amps
3
10
25
30
40
50
40
50
50
100
100
125
150
87DAA6MC
87DAB6MC
87DAD6MC
87DAE6MC
87EAF6MC
87EAG6MC
87FAH6MC
87FAJ6MC
87GAK6MC
87GAL6MC
87HAN6MC
87IAP6MC
87JAR6MC
available on Size 5 or above.
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Vacuum Starter Pump Panels
With Solid-State Overload Relay, Class 87
Selection
Coil Table
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/128.
Wiring Diagrams see page 8/145.
Replacement Parts see page 8/157.
Sizes 4-6 will be supplied standard with a 480 volt coil. To change
the coil voltage, change the 8th character in the catalog number to
the letter shown in the coil table.
60Hz Voltage
***
24 Separate Control
120 Separate Control
200–208
220–240
277
440–480
550–600
J
F
D
G
L
H
E
Fusible Disconnect
Max Hp
460 Volts
100
200
575 Volts
100
200
NEMA Size
4
5
Overload Range
55-250A
55-250A
Fuse Clip
Amps/Volts
200A/600V
400A/600V
Catalog Number
87JCM4F*
87LCU4F*
List Price $
575 Volts
100
200
300
400
NEMA Size
4
5
6
6
Overload Range
55-250A
55-250A
160-630A
160-630A
Circuit Breaker
Rating Amps
250A
400A
400A
600A
Catalog Number
87JCM4M*
87LCT4M*
87MCW4M*
87MCX4M*
List Price $
Circuit Breaker
Max Hp
460 Volts
100
200
250
400
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one maximum Hp rating.
Siemens Industry, Inc.
Industrial Controls Catalog
Product Category: NEMA
8/61
Reduced Voltage Pump Panels
Auto Transformer & Part Winding [2 Step] with Solid State Overload, Class 88
Selection
Coil and Control Voltage
Ordering Information
䊳
䊳
䊳
䊳
䊳
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/128.
Wiring Diagrams see pages 8/138 and 8/139.
Replacement Parts see page 8/157.
The coil voltage on the contactors will be
the motor voltage. A CPT will be supplied
to provide the control voltage. The control
voltage will be 120V.
To change the control voltage to customer
supplied (no CPT included), change the
9th character to the following:
for 24V , use ”J”
for 120V, use ”F”
Auto Transformer Type
Overload
Motor
Voltage
230
460
Fusible Disconnect
Circuit Breaker
Max
Hp
Amp
Range
Frame
Size
NEMA
Size
Half
Size
Fuse Clip Size
Amps/Volts
Catalog
Number
15
13–52
B
2
—
60A/250V
20
25–100
B
—
21⁄2
100A/250V
30
25–100
B
3
—
40
50–200
B
—
50
50–200
B
75
55–250
100
List
Price $
Circuit Breaker
Amps
Catalog
Number
88FUFT2FG
50
88FUFT2MG
88GUGT2FG
100
88GUGT2MG
100A/250V
88HUGT2FG
100
88HUGT2MG
31⁄2
200A/250V
88IUHT2FG
125
88IUHT2MG
4
—
200A/250V
88JUHT2FG
150
88JUHT2MG
—
5
—
—
—
250
88LPST2MG
55–250
—
5
—
400A/250V
88LPUT2FG
400
88LPUT2MG
200
160–630
—
6
—
—
—
600
88MSXT2MG
25
13–52
B
2
—
60A/600V
88FUFT4FH
50
88FUFT4MH
30
25–100
B
—
21⁄2
60A/600V
88GUGT4FH
50
88GUGT4MH
50
25–100
B
3
—
100A/600V
88HUGT4FH
100
88HUGT4MH
75
50–200
B
—
31⁄2
200A/600V
88IUHT4FH
125
88IUHT4MH
100
50–200
B
4
—
200A/600V
88JUHT4FH
150
88JUHT4MH
150
55–250
—
5
—
—
—
250
88LPST4MH
200
55–250
—
5
—
400A/600V
88LPSP2MH
400
88LPST4MH
400
160–630
—
6
—
600A/600V
88MSXT4FH
600
88MSXT4MH
—
—
—
List
Price $
Part Winding 2 Step
Overload
Motor
Voltage
230
460
Fusible Disconnect
Amp
Range
Frame
Size
NEMA
Size
Half
Size
Fuse Clip Size
Amps/Volts
Catalog
Number
Circuit Breaker
Amps
Catalog
Number
20
10–40
A1
—
13⁄4
100A/250V
25
13–52
B
2
—
100A/250V
88EUEP2FG
100
88EUEP2MG
88FUFP2FG
100
40
25–100
B
—
21⁄2
88FUFP2MG
200A/250V
88GUGP2FG
100
50
25–100
B
3
88GUGP2MG
—
200A/250V
88HUGP2FG
150
60
50–200
B
88HUGP2MG
—
31⁄2
200A/250V
88IUHP2FG
250
75
50–200
88IUHP2MG
B
4
—
400A/250V
88JUHP2FG
250
125
88JUHP2MG
55–250
—
5
—
—
—
400
88LPSP2MG
150
55–250
—
5
—
600A/250V
88LPUP2FG
600
88LPUP2MG
30
10–40
A1
—
13⁄4
100A/600V
88EUEP4FH
100
88EUEP4MH
40
13–52
B
2
—
100A/600V
88FUFP4FH
100
88FUFP4MH
60
25–100
B
—
21⁄2
200A/600V
88GUGP4FH
100
88GUGP4MH
75
25–100
B
3
—
200A/600V
88HUGP4FH
150
88HUGP4MH
100
50–200
B
—
31⁄2
200A/600V
88IUHP4FH
250
88IUHP4MH
150
50–200
B
4
—
400A/600V
88JUHP4FH
250
88JUHP4MH
250
55–250
—
5
—
—
—
400
88LPSP4MH
350
55–250
—
5
—
600A/600V
88LPUP4FH
600
88LPSP4MH
Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
8/62
Circuit Breaker
Max
Hp
List
Price $
—
—
List
Price $
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009. Continue
to order enclosed starters with the ESP100 OLR until
then.
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Reduced Voltage Pump Panels
Wye Delta with Solid State Overload, Class 88
Selection
Coil and Control Voltage
Ordering Information
䊳
䊳
䊳
䊳
䊳
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/128.
Wiring Diagrams see pages 8/140 and 8/141.
Replacement Parts see page 8/157.
The coil voltage on the contactors will be
the motor voltage. A CPT will be supplied
to provide the control voltage. The control
voltage will be 120V.
To change the control voltage to customer
supplied (no CPT included), change the
9th character to the following:
for 24V , use ”J”
for 120V, use ”F”
Wye Delta
Overload
Motor
Max Amp
Voltage Hp
Range
200
230
460
575
Frame NEMA Half Fuse Clip Size
Size
Size
Size Amps/Volts
Motor
Circuit
Interruter
ETI Amps
Open Transition
Fusible Disconnect
Circuit Breaker
Catalog
Number
Catalog
Number
List
Price $
List
Price $
Closed Transition
Fusible Disconnect
Circuit Breaker
Catalog
Number
Catalog
Number
List
Price $
10
10–40
A1
1
—
60A/250V
50
88DUE06FD
88DUE06MD
88DUEC6FD
88DUEC6MD
15
10–40
A1
—
13⁄4
100A/250V
100
88EUE06FD
88EUE06MD
88EUEC6FD
88EUEC6MD
20
13–52
B
2
—
100A/250V
100
88FUF06FD
88FUF06MD
88FUFC6FD
88FUFC6MD
30
25–100
B
—
21⁄2
200A/250V
125
88GUG06FD
88GUG06MD
88GUGC6FD
88GUGC6MD
40
25–100
B
3
—
200A/250V
150
88HUG06FD
88HUG06MD
88HUGC6FD
88HUGC6MD
50
50–200
B
—
31⁄2
200A/250V
250
88IUH06FD
88IUH06MD
88IUHC6FD
88IUHC6MD
60
50–200
B
4
—
400A/250V
250
88JUH06FD
88JUH06MD
88JUHC6FD
88JUHC6MD
75
55–250
—
5
—
400A/600V
400
88LPS06FD
88LPS06MD
88LPSC6FD
88LPSC6MD
150
55–250
—
5
—
600A/600V
600
88LPU06FD
88LPU06MD
88LPUC6FD
300
160–630 —
6
—
—
800
—
88MSX06MD
—
10
10–40
A1
1
—
60A/250V
50
88DUE02FG
88DUE02MG
88DUEC2FG
88DUEC2MG
15
10–40
A1
—
13⁄4
60A/250V
50
88EUE02FG
88EUE02MG
88EUEC2FG
88EUEC2MG
25
13–52
B
2
—
100A/250V
100
88FUF02FG
88FUF02MG
88FUFC2FG
88FUFC2MG
30
25–100
B
—
21⁄2
200A/250V
100
88GUG02FG
88GUG02MG
88GUGC2FG
88GUGC2MG
50
25–100
B
3
—
200A/250V
150
88HUG02FG
88HUG02MG
88HUGC2FG
88HUGC2MG
60
50–200
B
—
31⁄2
200A/250V
250
88IUH02FG
88IUH02MG
88IUHC2FG
88IUHC2MG
75
50–200
B
4
—
400A/250V
250
88JUH02FG
88JUH02MG
88JUHC2FG
88JUHC2MG
100
55–250
—
5
—
400A/250V
400
88LPS02FG
88LPS02MG
88LPSC2FG
88LPSC2MG
150
55–250
—
5
—
600A/250V
600
88LPU02FG
88LPU02MG
88LPUC2FG
350
160–630 —
6
—
—
1200
—
—
88MSX02MG
—
—
88MSXC2MG
15
10–40
A1
1
—
60A/600V
30
—
—
—
—
—
—
30
10–40
A1
—
13⁄4
60A/600V
50
88EUE04FH
88EUE04MH
88EUEC4FH
88EUEC4MH
40
13–52
B
2
—
100A/600V
100
88FUF04FH
88FUF04MH
88FUFC4FH
88FUFC4MH
60
25–100
B
—
21⁄2
200A/600V
100
88GUG04FH
88GUG04MH
88GUGC4FH
88GUGC4MH
75
25–100
B
3
—
200A/600V
125
88HUG04FH
88HUG04MH
88HUGC4FH
88HUGC4MH
100
50–200
B
—
31⁄2
200A/600V
150
88IUH04FH
88IUH04MH
88IUHC4FH
88IUHC4MH
150
50–200
B
4
—
400A/600V
250
88JUH04FH
88JUH04MH
88JUHC4FH
88JUHC4MH
200
55–250
—
5
—
400A/600V
400
88LPS04FH
88LPU04MH
88LPSC4FH
88LPSC4MH
300
55–250
—
5
—
600A/600V
600
88LPU04FH
88LPU04MH
88LPUC4FH
700
160–630 —
6
—
—
1200
—
—
88MSX04MH
—
—
88MSXC4MH
15
10–40
A1
1
—
60A/600V
30
—
—
—
—
—
—
30
10–40
A1
—
13⁄4
60A/600V
50
88EUE05FE
88EUE05ME
88EUEC5FE
88EUEC5ME
40
13–52
B
2
—
100A/600V
50
88FUF05FE
88FUF05ME
88FUFC5FE
88FUFC5ME
60
25–100
B
—
21⁄2
200A/600V
100
88GUG05FE
88GUG05ME
88GUGC5FE
88GUGC5ME
75
25–100
B
3
—
200A/600V
125
88HUG05FE
88HUG05ME
88HUGC5FE
88HUGC5ME
100
50–200
B
—
31⁄2
200A/600V
150
88IUH05FE
88IUH05ME
88IUHC5FE
88IUHC5ME
150
50–200
B
4
—
400A/600V
250
88JUH05FE
88JUH05ME
88JUHC5FE
88JUHC5ME
200
55–250
—
5
—
400A/600V
400
88LPS05FE
88LPU05ME
88LPSC5FE
88LPSC5ME
300
55–250
—
5
—
600A/600V
400
88LPU05FE
88LPU05ME
88LPUC5FE
700
160–630 —
6
—
—
1200
—
88MSX05ME
—
Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
Siemens Industry, Inc.
Industrial Controls Catalog
—
—
—
—
List
Price $
88LPUC6MD
—
88MSXC6MD
88LPUC2MG
—
88LPUC4MH
—
88LPUC5ME
—
88MSXC5ME
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009. Continue
to order enclosed starters with the ESP100 OLR until
then.
Product Category: NEMA
8/63
Reduced Voltage Heavy Duty Starters
Features and Benefits
General
Siemens manufactures the three commonly used electromechanical reduced
voltage starters. Each one is designed
for specific application requirements
and consists of auto transformer,
wye-delta and partwinding starters.
The reduced voltage starter:
▪ Reduces inrush current
▪ Provides smoother acceleration of the
load
▪ Reduces starting torque
▪ Reduces stresses on mechanical
linkages
Combination and non-combination
reduced voltage starter sizes range
from 0 to 6 including Siemens exclusive
motormatched half-sizes. Enclosure
types include 1, 3R/12, 4 painted and
4/4X stainless steel. UL listed file
#E14900 (class 36); file #E185287
(class 37). CSA certified file #LR 6535
(class 36 & 37).
Auto Transformer Starter
▪ Maximum torque per amp
▪ Three coil auto transformer for balanced starting currents
▪ 50, 65 and 80% voltage taps
▪ Closed circuit transition
▪ Adjustable starting time
▪ ESP200 overload as standard
▪ CPT supplied as standard
▪ Wide range of factory modifications
Wye-Delta Starter
▪ Lowest starting torque
▪ Closed or open circuit transition
▪ Adjustable starting time
▪ ESP200 overload as standard
▪ CPT supplied as standard
▪ Wide range of factory modifications
Part-Winding Starter
▪ Simplest design – most economical
▪ Adjustable starting time
▪ ESP200 overload as standard
▪ CPT supplied as standard
▪ Wide range of factory modifications
Various Methods of Electro-Mechanical Reduced Voltage Motor Starting
— A General Comparison
Autotransformer
Characteristic
Starting current drawn from
line as % of that which would
be drawn upon full voltage
starting
Starting current drawn by the
motor
Starting torque developed as
% of that which would be
developed on full voltage
starting
Smoothness of acceleration
Part-Winding
65%
Tap
80%
Tap
2 step
25%
42%
64%
65%
33%
50%
65%
80%
65%
58%
64%
40%
33%
Third in order of
Smoothness
Second in order of
Smoothness
5 seconds max.
Limited by motor
design
5-60 seconds
Limited by motor
design
Fixed
Fixed
25%
42%
Increases slightly
with speed
Allowable accelerating times
(typical)
First in order of
Smoothness
15 seconds at 200HP
max. or 30 seconds on
200HP based on
NEMA medium duty
transformers
Starting current and torque
and adjustments
Adjustable within limits
of various taps
8/64
Wye-Delta
50%
Tap
Siemens Industry, Inc.
Industrial Controls Catalog
Reduced Voltage Heavy Duty Starters
Auto Transformer with Solid State Overload, Class 36 & 37
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
Coil and Control Voltage
The coil voltage will always match the
motor voltage.
As standard, a CPT is supplied and 120V
control voltage is utilized.
To change to 120V separate control
voltage (CPT not supplied), change the
9th character to “F”.
To change to 24VAC separate control
voltage (CPT not supplied), change the
9th character to “J”.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/126.
Wiring Diagrams see page 8/139.
Replacement Parts see page 8/157.
For additional enclosure options see page 8/98.
NEMA 1 General Purpose Enclosures
Non-Combination
Enclosure
Overload
Motor Max NEMA Half Amp
Voltage Hp
Size
Size Range
200
230
460
575
Frame Catalog
Size
Number
List
Price $
Combination Non-Fusible
Disconnect
Catalog
Number
List
Price $
Fuse Clip
Size
Amps/Volts
Combination Fusible
Disconnect
Catalog
Number
List
Price $
Combination Circit
Circuit Breaker
Breaker Catalog
List
Amps
Number
Price $
10
—
13⁄4
10–40
A1
36EUET6BD
37EUET6BDD
60A/250V
37EUET6BDF
50
37EUET6BDP
10
2
—
13–52
B
36FUFT6BD
37FUFT6BDD
60A/250V
37FUFT6BDF
50
37FUFT6BDP
15
—
21⁄2
25–100
B
36GUGT6BD
37GUGT6BDD
100A/250V
37GUGT6BDF
100
37GUGT6BDP
25
3
—
25–100
B
36HUGT6BD
37HUGT6BDD
100A/250V
37HUGT6BDF
100
37HUGT6BDP
30
—
31⁄2
50–200
B
36IUHT6BD
37IUHT6BDD
200A/250V
37IUHT6BDF
125
37IUHT6BDP
40
4
—
50–200
B
36JUHT6BD
37JUHT6BDD
200A/250V
37JUHT6BDF
150
37JUHT6BDP
50
5
—
55–250
—
—
—
—
250
37LPST6BDP
75
5
—
55–250
—
36LPUT6BD
37LPUT6BDD
400A/250V
37LPUT6BDF
400
37LPUT6BDP
150
6
—
160–630 —
36MPXT6BD
37MPXT6BDD
600A/250V
37MPXT6BDF
600
37MPXT6BDP
10
—
13⁄4
10–40
A1
36EUET2BG
37EUET2BGD
60A/250V
37EUET2BGF
50
37EUET2BGP
15
2
—
13–52
B
36FUFT2BG
37FUFT2BGD
60A/250V
37FUFT2BGF
50
37FUFT2BGP
20
—
21⁄2
25–100
B
36GUGT2BG
37GUGT2BGD
100A/250V
37GUGT2BGF
100
37GUGT2BGP
30
3
—
25–100
B
36HUGT2BG
37HUGT2BGD
100A/250V
37HUGT2BGF
100
37HUGT2BGP
40
—
31⁄2
50–200
B
36IUHT2BG
37IUHT2BGD
200A/250V
37IUHT2BGF
125
37IUHT2BGP
50
4
—
50–200
B
36JUHT2BG
37JUHT2BGD
200A/250V
37JUHT2BGF
150
37JUHT2BGP
75
5
—
55–250
—
—
—
—
250
37LPST2BGP
100
5
—
55–250
—
36LPUT2BG
37LPUT2BGD
400A/250V
37LPUT2BGF
400
37LPUT2BGP
200
6
—
160–630 —
36MPXT2BG
37MPXT2BGD
600A/250V
37MPXT2BGF
600
37MPXT2BGP
15
—
13⁄4
10–40
A1
36EUET4BH
37EUET4BHD
60A/250V
37EUET4BHF
50
37EUET4BHP
25
2
—
13–52
B
36FUFT4BH
37FUFT4BHD
60A/250V
37FUFT4BHF
50
37FUFT4BHP
30
—
21⁄2
13–52
B
36GUGT4BH
37GUGT4BHD
100A/250V
37GUGT4BHF
100
37GUGT4BHP
50
3
—
25–100
B
36HUGT4BH
37HUGT4BHD
100A/250V
37HUGT4BHF
100
37HUGT4BHP
75
—
31⁄2
50–200
B
36IUHT4BH
37IUHT4BHD
200A/250V
37IUHT4BHF
125
37IUHT4BHP
100
4
—
50–200
B
36JUHT4BH
37JUHT4BHD
200A/250V
37JUHT4BHF
150
37JUHT4BHP
150
5
—
55–250
—
—
—
—
250
37LPST4BHP
200
5
—
55–250
—
36LPUT4BH
37LPUT4BHD
400A/250V
37LPUT4BHF
400
37LPUT4BHP
400
6
—
160–630 —
36MPXT4BH
37MPXT4BHD
600A/250V
37MPXT4BHF
600
37MPXT4BHP
15
—
13⁄4
10–40
36EUET5BE
37EUET5BED
60A/250V
37EUET5BEF
50
37EUET5BEP
25
2
—
---13–52 B
36FUFT5BE
37FUFT5BED
60A/250V
37FUFT5BEF
50
37FUFT5BEP
30
—
21⁄2
13–52
B
36GUGT5BE
37GUGT5BED
100A/250V
37GUGT5BEF
100
37GUGT5BEP
50
3
—
25–100
B
36HUGT5BE
37HUGT5BED
100A/250V
37HUGT5BEF
100
37HUGT5BEP
75
—
31⁄2
50–200
B
36IUHT5BE
37IUHT5BED
200A/250V
37IUHT5BEF
125
37IUHT5BEP
100
4
—
50–200
B
36JUHT5BE
37JUHT5BED
200A/250V
37JUHT5BEF
150
37JUHT5BEP
150
5
—
55–250
—
—
—
—
250
37LPUT5BEP
200
5
—
55–250
—
36LPUT5BE
37LPUT5BED
400A/250V
37LPUT5BEF
400
37LPUT5BEP
400
6
—
160–630 —
36MPXT5BE
37MPXT5BED
600A/250V
37MPXT5BEF
600
37MPXT5BEP
A1
Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
Siemens Industry, Inc.
Industrial Controls Catalog
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009. Continue
to order enclosed starters with the ESP100 OLR until
then.
Product Category: NEMA
8/65
Reduced Voltage Heavy Duty Starters
2 Step Part Winding with Solid State Overload, Class 36 & 37
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
Coil and Control Voltage
The coil voltage will always match the
motor voltage.
As standard, a CPT is supplied and 120V
control voltage is utilized.
To change to 120V separate control
voltage (CPT not supplied), change
the 9th character to “F”.
To change to 24VAC separate control
voltage (CPT not supplied), change the
9th character to “J”.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/126.
Wiring Diagrams see page 8/138.
Replacement Parts see page 8/157.
For additional enclosure options see page 8/98.
NEMA 1 General Purpose Enclosures
Non-Combination
Enclosure
Overload
Motor
Voltage
200
230
460
575
Max NEMA
Hp
Size
Half
Size
Amp
Range
Frame Catalog
Size
Number
71⁄2
10
15
20
30
40
50
75
100
150
71⁄2
10
20
25
30
50
60
75
125
150
300
10
15
30
40
60
75
100
150
250
350
600
10
15
30
40
60
75
100
150
250
350
600
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
5.5–22
5.5–22
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
5.5–22
5.5–22
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
5.5–22
5.5–22
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
5.5–22
5.5–22
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
A1
A1
A1
B
B
B
B
B
—
—
A1
A1
A1
B
B
B
B
B
—
—
—
A1
A1
A1
B
B
B
B
B
—
—
—
A1
A1
A1
B
B
B
B
B
—
—
—
0
1
—
2
—
3
—
4
5
5
0
1
—
2
—
3
—
4
5
5
6
0
1
—
2
—
3
—
4
5
5
6
0
1
—
2
—
3
—
4
5
5
6
36CUDP6BD
36DUDP6BD
36EUEP6BD
36FUFP6BD
36GUGP6BD
36HUGP6BD
36IUHP6BD
36JUHP6BD
—
36LPUP6BD
36CUDP2BG
36DUDP2BG
36EUEP2BG
36FUFP2BG
36GUGP2BG
36HUGP2BG
36IUHP2BG
36JUHP2BG
—
36LPUP2BG
36MPXP2BG
36CUDP4BH
36DUDP4BH
36EUEP4BH
36FUFP4BH
36GUGP4BH
36HUGP4BH
36IUHP4BH
36JUHP4BH
—
36LPUP4BH
36MPXP4BH
36CUDP5BE
36DUDP5BE
36EUEP5BE
36FUFP5BE
36GUGP5BE
36HUGP5BE
36IUHP5BE
36JUHP5BE
—
36LPUP5BE
36MPXP5BE
Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
8/66
List
Price $
—
—
—
—
Combination Non-Fusible
Disconnect
Fuse Clip
Catalog
List
Size
Number
Price $
Amps/Volts
Combination Fusible
Disconnect
37CUDP6BDD
37DUDP6BDD
37EUEP6BDD
37FUFP6BDD
37GUGP6BDD
37HUGP6BDD
37IUHP6BDD
37JUHP6BDD
—
37LPUP6BDD
37CUDP2BGD
37DUDP2BGD
37EUEP2BGD
37FUFP2BGD
37GUGP2BGD
37HUGP2BGD
37IUHP2BGD
37JUHP2BGD
—
37LPUP2BGD
37MPXP2BGD
37CUDP4BHD
37DUDP4BHD
37EUEP4BHD
37FUFP4BHD
37GUGP4BHD
37HUGP4BHD
37IUHP4BHD
37JUHP4BHD
—
37LPUP4BHD
37MPXP4BHD
37CUDP5BED
37DUDP5BED
37EUEP5BED
37FUFP5BED
37GUGP5BED
37HUGP5BED
37IUHP5BED
37JUHP5BED
—
37LPUP5BED
37MPXP5BED
37CUDP6BDF
37DUDP6BDF
37EUEP6BDF
37FUFP6BDF
37GUGP6BDF
37HUGP6BDF
37IUHP6BDF
37JUHP6BDF
—
37LPUP6BDF
37CUDP2BGF
37DUDP2BGF
37EUEP2BGF
37FUFP2BGF
37GUGP2BGF
37HUGP2BGF
37IUHP2BGF
37JUHP2BGF
—
37LPUP2BGF
37MPXP2BGF
37CUDP4BHF
37DUDP4BHF
37EUEP4BHF
37FUFP4BHF
37GUGP4BHF
37HUGP4BHF
37IUHP4BHF
37JUHP4BHF
—
37LPUP4BHF
37MPXP4BHF
37CUDP5BEF
37DUDP5BEF
37EUEP5BEF
37FUFP5BEF
37GUGP5BEF
37HUGP5BEF
37IUHP5BEF
37JUHP5BEF
37LPSP5BEF
37LPUP5BEF
37MPXP5BEF
—
—
—
—
60A/250V
60A/250V
100A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
—
600A/250V
60A/250V
60A/250V
100A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
—
600A/250V
1200A/250V
30A/600V
60A/600V
60A/600V
100A/600V
200A/600V
200A/600V
200A/600V
400A/600V
—
600A/600V
1200A/600V
30A/600V
60A/600V
60A/600V
60A/600V
100A/600V
200A/600V
400A/600V
400A/600V
400A/600V
600A/600V
1200A/600V
Catalog
Number
List
Price $
—
—
—
Circuit
Breaker
Amps
30
50
100
100
125
150
250
400
600
600
30
50
100
100
100
150
250
250
400
600
1200
30
30
50
100
100
125
150
250
400
600
1200
30
30
50
50
100
125
150
250
—
400
1200
Combination Circit
Breaker
Catalog
Number
37CUDP6BDP
37DUDP6BDP
37EUEP6BDP
37FUFP6BDP
37GUGP6BDP
37HUGP6BDP
37IUHP6BDP
37JUHP6BDP
37LPSP6BDP
37LPUP6BDP
37CUDP2BGP
37DUDP2BGP
37EUEP2BGP
37FUFP2BGP
37GUGP2BGP
37HUGP2BGP
37IUHP2BGP
37JUHP2BGP
37LPSP2BGP
37LPUP2BGP
37MPXP2BGP
37CUDP4BHP
37DUDP4BHP
37EUEP4BHP
37FUFP4BHP
37GUGP4BHP
37HUGP4BHP
37IUHP4BHP
37JUHP4BHP
37LPSP4BHP
37LPUP4BHP
37MPXP4BHP
37CUDP5BEP
37DUDP5BEP
37EUEP5BEP
37FUFP5BEP
37GUGP5BEP
37HUGP5BEP
37IUHP5BEP
37JUHP5BEP
—
37LPUP5BEP
37MPXP5BEP
List
Price $
—
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009. Continue
to order enclosed starters with the ESP100 OLR until
then.
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Reduced Voltage Heavy Duty Starters
Wye Delta, Open Transition with Solid State Overload, Class 36 & 37
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
Coil and Control Voltage
The coil voltage will always match the
motor voltage.
As standard, a CPT is supplied and 120V
control voltage is utilized.
To change to 120V separate control
voltage (CPT not supplied), change
the 9th character to “F”.
To change to 24VAC separate control
voltage (CPT not supplied), change the
9th character to “J”.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/126.
Wiring Diagrams see page 8/140.
Replacement Parts see page 8/157.
For additional enclosure options see page 8/98.
NEMA 1 General Purpose Enclosures
Non-Combination
Enclosure
Overload
Combination Fusible
Disconnect
List
Price $
Combination Circit
Breaker
Max NEMA
Hp
Size
Half
Size
Amp
Range
Frame Catalog
Size
Number
200
10
15
20
30
40
50
60
75
150
300
1
—
2
—
3
—
4
5
5
6
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
A1
A1
B
B
B
B
B
—
—
—
36DUE06BD
36EUE06BD
36FUF06BD
36GUG06BD
36HUG06BD
36IUH06BD
36JUH06BD
36LPS06BD
36LPU06BD
36MPX06BD
37DUE06BDD
37EUE06BDD
37FUF06BDD
37GUG06BDD
37HUG06BDD
37IUH06BDD
37JUH06BDD
37LPS06BDD
37LPU06BDD
37MPX06BDD
60A/250V
100A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
400A/250V
600A/250V
1200A/250V
37DUE06BDF
37EUE06BDF
37FUF06BDF
37GUG06BDF
37HUG06BDF
37IUH06BDF
37JUH06BDF
37LPS06BDF
37LPU06BDF
37MPX06BDF
50
100
100
125
150
250
250
400
600
1200
37DUE06BDP
37EUE06BDP
37FUF06BDP
37GUG06BDP
37HUG06BDP
37IUH06BDP
37JUH06BDP
37LPS06BDP
37LPU06BDP
37MPX06BDP
230
10
15
25
30
50
60
75
100
150
350
1
—
2
—
3
—
4
5
5
6
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
A1
A1
B
B
B
B
B
—
—
—
36DUE02BG
36EUE02BG
36FUF02BG
36GUG02BG
36HUG02BG
36IUH02BG
36JUH02BG
36LPS02BG
36LPU02BG
36MPX02BG
37DUE02BGD
37EUE02BGD
37FUF02BGD
37GUG02BGD
37HUG02BGD
37IUH02BGD
37JUH02BGD
37LPS02BGD
37LPU02BGD
37MPX02BGD
60A/250V
60A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
400A/250V
600A/250V
1200A/250V
37DUE02BGF
37EUE02BGF
37FUF02BGF
37GUG02BGF
37HUG02BGF
37IUH02BGF
37JUH02BGF
37LPS02BGF
37LPU02BGF
37MPX02BGF
50
50
100
100
150
250
250
400
600
1200
37DUE02BGP
37EUE02BGP
37FUF02BGP
37GUG02BGP
37HUG02BGP
37IUH02BGP
37JUH02BGP
37LPS02BGP
37LPU02BGP
37MPX02BGP
460
15
30
40
60
75
100
150
200
300
700
1
—
2
—
3
—
4
5
5
6
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
A1
A1
B
B
B
B
B
—
—
—
36DUD04BH
36EUE04BH
36FUF04BH
36GUG04BH
36HUG04BH
36IUH04BH
36JUH04BH
36LPS04BH
36LPU04BH
36MPX04BH
37DUD04BHD
37EUE04BHD
37FUF04BHD
37GUG04BHD
37HUG04BHD
37IUH04BHD
37JUH04BHD
37LPS04BHD
37LPU04BHD
37MPX04BHD
30A/600V
60A/600V
100A/600V
200A/600V
200A/600V
200A/600V
400A/600V
400A/600V
600A/600V
1600A/600V
37DUD04BHF
37EUE04BHF
37FUF04BHF
37GUG04BHF
37HUG04BHF
37IUH04BHF
37JUH04BHF
37LPS04BHF
37LPU04BHF
37MPX04BHF
30
50
100
100
125
150
250
400
600
1200
37DUD04BHP
37EUE04BHP
37FUF04BHP
37GUG04BHP
37HUG04BHP
37IUH04BHP
37JUH04BHP
37LPS04BHP
37LPU04BHP
37MPX04BHP
575
15
30
40
60
75
100
150
200
300
700
1
—
2
—
3
—
4
5
5
6
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
A1
A1
B
B
B
B
B
—
—
—
36DUD05BE
36EUE05BE
36FUF05BE
36GUG05BE
36HUG05BE
36IUK05BE
36JUH05BE
36LPS05BE
36LPU05BE
36MPX05BE
37DUD05BED
37EUE05BED
37FUF05BED
37GUG05BED
37HUG05BED
37IUK05BED
37JUH05BED
37LPS05BED
37LPU05BED
37MPX05BED
30A/600V
60A/600V
100A/600V
100A/600V
200A/600V
200A/600V
400A/600V
400A/600V
600A/600V
1600A/600V
37DUD05BEF
37EUE05BEF
37FUF05BEF
37GUG05BEF
37HUG05BEF
37IUK05BEF
37JUH05BEF
37LPS05BEF
37LPU05BEF
37MPX05BEF
30
50
50
100
125
150
250
250
400
1600
37DUD05BEP
37EUE05BEP
37FUF05BEP
37GUG05BEP
37HUG05BEP
37IUK05BEP
37JUH05BEP
37LPS05BEP
37LPU05BEP
37MPX05BEP
Siemens Industry, Inc.
Industrial Controls Catalog
Catalog
Number
Circuit
Breaker
Amps
Motor
Voltage
Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
List
Price $
Combination Non-Fusible
Disconnect
Fuse Clip
Catalog
List
Size
Number
Price $
Amps/Volts
Catalog
Number
List
Price $
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009. Continue
to order enclosed starters with the ESP100 OLR until
then.
Product Category: NEMA
8/67
Reduced Voltage Heavy Duty Starters
Wye Delta, Closed Transition with Solid State Overload, Class 36 & 37
Selection
Ordering Information
䊳
䊳
䊳
䊳
䊳
䊳
Coil and Control Voltage
The coil voltage will always match the
motor voltage.
As standard, a CPT is supplied and 120V
control voltage is utilized.
To change to 120V separate control
voltage (CPT not supplied), change
the 9th character to “F”.
To change to 24VAC separate control
voltage (CPT not supplied), change the
9th character to “J”.
Field Modification Kits see page 8/82.
Factory Modifications see page 8/95.
Dimensions see page 8/126.
Wiring Diagrams see page 8/141.
Replacement Parts see page 8/157.
For additional enclosure options see page 8/98.
NEMA 1 General Purpose Enclosures
Non-Combination
Enclosure
Overload
Combination Fusible
Disconnect
List
Price $
Combination Circit
Breaker
Max NEMA
Hp
Size
Half
Size
Amp
Range
Frame Catalog
Size
Number
200
10
15
20
30
40
50
60
75
150
300
1
—
2
—
3
—
4
5
5
6
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
A1
A1
B
B
B
B
B
—
—
—
36DUEC6BD
36EUEC6BD
36FUFC6BD
36GUGC6BD
36HUGC6BD
36IUHC6BD
36JUHC6BD
36LPSC6BD
36LPUC6BD
36MPXC6BD
37DUEC6BDD
37EUEC6BDD
37FUFC6BDD
37GUGC6BDD
37HUGC6BDD
37IUHC6BDD
37JUHC6BDD
37LPSC6BDD
37LPUC6BDD
37MPXC6BDD
60A/250V
100A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
400A/250V
600A/250V
1200A/250V
37DUEC6BDF
37EUEC6BDF
37FUFC6BDF
37GUGC6BDF
37HUGC6BDF
37IUHC6BDF
37JUHC6BDF
37LPSC6BDF
37LPUC6BDF
37MPXC6BDF
50
100
100
125
150
250
250
400
600
1200
37DUEC6BDP
37EUEC6BDP
37FUFC6BDP
37GUGC6BDP
37HUGC6BDP
37IUHC6BDP
37JUHC6BDP
37LPSC6BDP
37LPUC6BDP
37MPXC6BDP
230
10
15
25
30
50
60
75
100
150
350
1
—
2
—
3
—
4
5
5
6
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
A1
A1
B
B
B
B
B
—
—
—
36DUEC2BG
36EUEC2BG
36FUFC2BG
36GUGC2BG
36HUGC2BG
36IUHC2BG
36JUHC2BG
36LPSC2BG
36LPUC2BG
36MPXC2BG
37DUEC2BGD
37EUEC2BGD
37FUFC2BGD
37GUGC2BGD
37HUGC2BGD
37IUHC2BGD
37JUHC2BGD
37LPSC2BGD
37LPUC2BGD
37MPXC2BGD
60A/250V
60A/250V
100A/250V
200A/250V
200A/250V
200A/250V
400A/250V
400A/250V
600A/250V
1200A/250V
37DUEC2BGF
37EUEC2BGF
37FUFC2BGF
37GUGC2BGF
37HUGC2BGF
37IUHC2BGF
37JUHC2BGF
37LPSC2BGF
37LPUC2BGF
37MPXC2BGF
50
50
100
100
150
250
250
400
600
1200
37DUEC2BGP
37EUEC2BGP
37FUFC2BGP
37GUGC2BGP
37HUGC2BGP
37IUHC2BGP
37JUHC2BGP
37LPSC2BGP
37LPUC2BGP
37MPXC2BGP
460
15
30
40
60
75
100
150
200
300
700
1
—
2
—
3
—
4
5
5
6
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
A1
A1
B
B
B
B
B
—
—
—
36DUDC4BH
36EUEC4BH
36FUFC4BH
36GUGC4BH
36HUGC4BH
36IUHC4BH
36JUHC4BH
36LPSC4BH
36LPUC4BH
36MPXC4BH
37DUDC4BHD
37EUEC4BHD
37FUFC4BHD
37GUGC4BHD
37HUGC4BHD
37IUHC4BHD
37JUHC4BHD
37LPSC4BHD
37LPUC4BHD
37MPXC4BHD
30A/600V
60A/600V
100A/600V
200A/600V
200A/600V
200A/600V
400A/600V
400A/600V
600A/600V
1600A/600V
37DUDC4BHF
37EUEC4BHF
37FUFC4BHF
37GUGC4BHF
37HUGC4BHF
37IUHC4BHF
37JUHC4BHF
37LPSC4BHF
37LPUC4BHF
37MPXC4BHF
30
50
100
100
125
150
250
400
600
1200
37DUDC4BHP
37EUEC4BHP
37FUFC4BHP
37GUGC4BHP
37HUGC4BHP
37IUHC4BHP
37JUHC4BHP
37LPSC4BHP
37LPUC4BHP
37MPXC4BHP
575
15
30
40
60
75
100
150
200
300
700
1
—
2
—
3
—
4
5
5
6
—
13⁄4
—
21⁄2
—
31⁄2
—
—
—
—
10–40
10–40
13–52
25–100
25–100
50–200
50–200
55–250
55–250
160–630
A1
A1
B
B
B
B
B
—
—
—
36DUDC5BE
36EUEC5BE
36FUFC5BE
36GUGC5BE
36HUGC5BE
36IUKC5BE
36JUHC5BE
36LPSC5BE
36LPUC5BE
37MPXC5BF
37DUDC5BED
37EUEC5BED
37FUFC5BED
37GUGC5BED
37HUGC5BED
37IUKC5BED
37JUHC5BED
37LPSC5BED
37LPUC5BED
37MPXC5BED
30A/600V
60A/600V
100A/600V
100A/600V
200A/600V
200A/600V
400A/600V
400A/600V
600A/600V
1600A/600V
37DUDC5BEF
37EUEC5BEF
37FUFC5BEF
37GUGC5BEF
37HUGC5BEF
37IUKC5BEF
37JUHC5BEF
37LPSC5BEF
37LPUC5BEF
37MPXC5BEF
30
50
50
100
125
150
250
250
400
1600
37DUDC5BEP
37EUEC5BEP
37FUFC5BEP
37GUGC5BEP
37HUGC5BEP
37IUKC5BEP
37JUHC5BEP
37LPSC5BEP
37LPUC5BEP
37MPXC5BEP
8/68
Catalog
Number
Circuit
Breaker
Amps
Motor
Voltage
Note: All starter sizes carry one maximum Hp rating (per the
National Electric Code).
List
Price $
Combination Non-Fusible
Disconnect
Fuse Clip
Catalog
List
Size
Number
Price $
Amps/Volts
Catalog
Number
List
Price $
Enclosed
starters with the ESP200 OLR will not be
available until approximately December 2009. Continue
to order enclosed starters with the ESP100 OLR until
then.
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Lighting and Heating Control
Electrically Held Lighting Contactors
General
Features
Application
▪
▪
▪
▪
▪
▪
▪
Siemens electrically held lighting
contactors provide a safe, convenient
means of local or remote switching
for tungsten and ballast lamp loads,
mercury arc lamps, and 3-phase
resistive heating.
Compact Design
Silver Cadmium Oxide Contacts
Pressure Type Terminals
Straight Thru Wiring
Wide Variety of Contact Configurations
12-Poles Maximum
Available From 20 Amps–400 Amps
Up to 12-Poles 20, 30 and 60 Amps
3-Poles On 100–400 Amps
▪ Full Line of Enclosures
NEMA 1
NEMA 3R/12
NEMA 4/4X (Stainless Steel)
▪ Available In Combination Form with
Choice of:
Fusible Disconnect
Non-Fusible Disconnect
Circuit Breaker
All
Combination Lighting Contactors
▪
are UL Service Entrance Listed
▪ Full Line of Factory And Field
Modifications
▪ UL Listed Files #E27683
▪ CSA Certified File LR 6535
Siemens Industry, Inc.
Industrial Controls Catalog
Class LE electrically held lighting
and heating contactors are used in
applications where it is not critical that
the contacts remain in the closed
position during loss of control power.
These lighting contactors are rated at
480V Tungsten, 600V Ballast. They are
available in 2–12 poles with a variety of
NO and NC contact arrangements.
Typical applications include:
▪ Industrial and Commercial Buildings
▪ Stadiums
▪ Airports
▪ Non-Critical Resistive Heaters and
other Non-Inductive Loads
8/69
Lighting and Heating Control
Electrically Held Lighting Contactors, Class LE
Selection
Ordering Information
Coil Table
Replace the *** with a number from the coil table.
Field modifications see page 8/82.
왘 Factory modification kits see page 8/95.
왘 Dimensions see page 8/111 open page 8/129 enclosed.
왘 Wiring Diagrams see page 8/146.
왘 Replacement parts see page 8/160.
60Hz Voltage
Number
24
120
208
240
277
480
600
024
120
208
240
277
480
600
왘
왘
Open and Non-combination Enclosed Contactors
Open Type
NEMA 1
NEMA 12
NEMA 3/3R
General Purpose
Max.
Amp
Rating
Number
of
Poles
2
3
4
6
20
8
9
10
12
30
60
100
200
300
400
3
6
9
12
3
6
9
12
3
3
3
3
Industrial Use
Weatherproof
Normally
Closed
Contacts
Normally
Open
Contacts
Catalog Number
2
0
3
0
4
2
1
0
2
0
4
2
0
4
2
0
4
2
0
4
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
0
3
0
2
3
4
4
6
4
6
8
5
7
9
6
8
10
8
10
12
3
6
9
12
3
6
9
12
3
3
3
3
LEN00B200***A
LEN00B002***A
LEN00B300***A
LEN00B003***A
LEN00B400***A
LEN00B202***A
LEN00B103***A
LEN00B004***A
LEN00B204***A
LEN00B006***A
LEN00B404***A
LEN00B206***A
LEN00B008***A
LEN00B405***A
LEN00B207***A
LEN00B009***A
LEN00B406***A
LEN00B208***A
LEN00B010***A
LEN00B408***A
LEN00B210***A
LEN00B012***A
LEN00C003***A
LEN00C006***A
LEN00C009***A
LEN00C012***A
LEN00D003***A
LEN00D006***A
LEN00D009***A
LEN00D012***A
LEN00E003***A
LEN00F003***A
LEN00G003***A
LEN00H003***A
List Price $
Catalog Number
List Price $
LEN01B200***A
LEN01B002***A
LEN01B300***A
LEN01B003***A
LEN01B400***A
LEN01B202***A
LEN01B103***A
LEN01B004***A
LEN01B204***A
LEN01B006***A
LEN01B404***A
LEN01B206***A
LEN01B008***A
LEN01B405***A
LEN01B207***A
LEN01B009***A
LEN01B406***A
LEN01B208***A
LEN01B010***A
LEN01B408***A
LEN01B210***A
LEN01B012***A
LEN01C003***A
LEN01C006***A
LEN01C009***A
LEN01C012***A
LEN01D003***A
LEN01D006***A
LEN01D009***A
LEN01D012***A
LEN01E003***A
LEN01F003***A
LEN01G003***A
LEN01H003***A
NEMA 4/4X Stainless Steel
Watertight, Dust-tight,
Corrosion Resistant,
304 Stainless Steel
Catalog Number
List Price $ Catalog Number
LEN02B200***A
LEN02B002***A
LEN02B300***A
LEN02B003***A
LEN02B400***A
LEN02B202***A
LEN02B103***A
LEN02B004***A
LEN02B204***A
LEN02B006***A
LEN02B404***A
LEN02B206***A
LEN02B008***A
LEN02B405***A
LEN02B207***A
LEN02B009***A
LEN02B406***A
LEN02B208***A
LEN02B010***A
LEN02B408***A
LEN02B210***A
LEN02B012***A
LEN02C003***A
LEN02C006***A
LEN02C009***A
LEN02C012***A
LEN02D003***A
LEN02D006***A
LEN02D009***A
LEN02D012***A
LEN02E003***A
LEN02F003***A
LEN02G003***A
LEN02H003***A
LEN04B200***A
LEN04B002***A
LEN04B300***A
LEN04B003***A
LEN04B400***A
LEN04B202***A
LEN04B103***A
LEN04B004***A
LEN04B204***A
LEN04B006***A
LEN04B404***A
LEN04B206***A
LEN04B008***A
LEN04B405***A
LEN04B207***A
LEN04B009***A
LEN04B406***A
LEN04B208***A
LEN04B010***A
LEN04B408***A
LEN04B210***A
LEN04B012***A
LEN04C003***A
LEN04C006***A
LEN04C009***A
LEN04C012***A
LEN04D003***A
LEN04D006***A
LEN04D009***A
LEN04D012***A
LEN04E003***A
LEN04F003***A
LEN04G003***A
LEN04H003***A
List Price $
For
conduit hubs and conversion instructions, see page
8/88.
be field assembled. Order mounting kit
49MCMPMA and required number of contactors.
Example, 3, three pole contactors and 1 mounting plate
for a 9-pole open assembly.
Can
8/70
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Lighting and Heating Control
Combination Electrically Held Lighting Contactors, Class LE
Selection
Ordering Information
Coil Table
Replace the *** with a number from the coil table.
Field modification kits see page 8/82.
왘 Factory modifications see page 8/95.
왘 Dimensions see page 8/129.
왘 Wiring Diagrams see page 8/146.
왘 Replacement parts see page 8/160.
왘
왘
60Hz Voltage
Number
24
120
208
240
277
480
600
024
120
208
240
277
480
600
Combination Lighting Contactors
NEMA 12, NEMA 3/3R
NEMA 4 Painted (thru 100 amps)
NEMA 1
General Purpose
Disconnect
Type
Non-Fusible
Max.
Amp
Rating
20
30
60
100
200
300
20
30
60
Fusible
100
200
300
Circuit
Breaker
20
30
60
100
Number
of NO
Poles
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Disc
Amp
Rating
Disc Amp/ Circuit
Fuse Clip Breaker
Rating
Rating
Catalog Number
30A
30A
60A
100A
200A
400A
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
30A/250V
30A/600V
30A/250V
30A/600V
60A/250V
60A/600V
100A/250V
100A/600V
200A/250V
200A/600V
400A/250V
400A/600V
—
—
—
—
LEDB1B003***A
LEDB1C003***A
LEDD1D003***A
LEDF1E003***A
LEDH1F003***A
LEDK1G003***A
LEFA1B003***A
LEFB1B003***A
LEFA1C003***A
LEFB1C003***A
LEFC1D003***A
LEFD1D003***A
LEFE1E003***A
LEFF1E003***A
LEFG1F003***A
LEFH1F003***A
LEFJ1G003***A
LEFK1G003***A
LEBT1B003***A
LEBV1C003***A
LEBY1D003***A
LEBZ1E003***A
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
20A
30A
60A
100A
List Price $
NEMA 4/4X Stainless Steel
Industrial Use
Weatherproof, Watertight, Dust-tight
Watertight, Dust-tight,
Corrosion Resistant
304 Stainless Steel
Catalog Number
Catalog Number
LEDB2B003***A
LEDB2C003***A
LEDD2D003***A
LEDF2E003***A
LEDH2F003***A
LEDK2G003***A
LEFA2B003***A
LEFB2B003***A
LEFA2C003***A
LEFB2C003***A
LEFC2D003***A
LEFD2D003***A
LEFE2E003***A
LEFF2E003***A
LEFG2F003***A
LEFH2F003***A
LEFJ2G003***A
LEFK2G003***A
LEBT2B003***A
LEBV2C003***A
LEBY2D003***A
LEBY2D003***A
List Price $
List Price $
LEDB4B003***A
LEDB4C003***A
LEDD4D003***A
LEDF4E003***A
LEDH4F003***A
LEDK4G003***A
LEFA4B003***A
LEFB4B003***A
LEFA4C003***A
LEFB4C003***A
LEFC4D003***A
LEFD4D003***A
LEFE4E003***A
LEFF4E003***A
LEFG4F003***A
LEFH4F003***A
LEFJ4G003***A
LEFK4G003***A
LEBT4B003***A
LEBV4C003***A
LEBY4D003***A
LEBZ4E003***A
For
conduit hubs and conversion instructions, see page
8/88.
Siemens Industry, Inc.
Industrial Controls Catalog
Product Category: NEMA
8/71
Lighting and Heating Contactors
Mechanically and Magnetically Held Lighting Contactors
Selection
CLM 20 Amp
CLM 100 Amp
Mechanically Latched Lighting
and Heating Contactor
The CLM Lighting Contactors can be
used with metal halide, mercury vapor,
quartz halogen, tungsten and fluorescent lighting. They provide reliable and
convenient lighting control in numerous
applications, such as industrial plants,
schools, hospitals, office buildings,
shopping centers, airports, stadiums . . .
literally everywhere lighting is required.
The CLMs are listed under UL 508 with
no derating when used open or
enclosed. Combination lighting
contactors are listed for UL service
entrance.
UL listed File #E60310
CSA Certified File LR 6535
Type CLM 20 Amp Lighting
Contactor Solid State Control
Modules
The CLM 20 amp lighting contactor
is an electromagnetically operated,
mechanically latched three wire control
contactor. The most commonly used
method of control is a three position
momentary contact switch with a
center-off position. The controlling
device must be able to make the coil
inrush current but need not break it.
The coil current is interrupted by the
control contacts within the CLM
contactor. Power for the control line may
come from a separate source or directly
from the line side of the CLM contactor.
The CLM contactor can also be
controlled by devices such as:
▪ Break-glass control stations
▪ Timers having single pole, double
throw contacts
▪ Photo-electric cells
▪ Energy management systems
▪ Microprocessors
▪ Occupancy sensors
Control modules make it possible to
use a controlling device that does not
have enough current-carrying capacity
to control the CLM contactor directly.
Control modules are also used when
Operation
8/72
the control station is to be located at
a distance greater than the allowable
contactor line run.
Another use for control modules occurs
when the controlling device is only
available as a single pole single-throw
contact necessitating a two wire
control line.
Still another application for control
modules is when start-stop three
wire control is needed.
Control modules also can make it
possible to operate the CLM coil from
its own incoming line at one voltage
while providing the control at a
second, perhaps lower voltage.
Two Wire Control Module
(Accessory 47)
The advantages of two wire controls are:
1. Control station can have lower
ampacity rating.
2. Control station can be located an
extended distance from the CLM
contactor.
3. Control module can frequently be
controlled directly from
microprocessor.
4. Control devices can be two wire
single pole, single-throw types.
5. Control voltage may be different than
the CLM coil circuit and at a lower
voltage level.
Note: If the control power to the solid
state control module is lost while the
module is energized the lighting
contactor will open. If the line power
to the lighting contactor is lost while the
contactor is energized the contactor will
not change state with return of line
voltage. Power will be restored to
the load if the control module is still
energized. Control station should
be the maintained type.
Three Wire Control Module
(Accessory 48)
1. The accessory 48 consists of two
relays with contacts appropriately
interconnected which provides for an
interlocking that prevents both relays
from being energized simultaneously.
2. This module has similar characteristics
to the two wire module (Accessory 47)
except there is no change of switch
contact position upon loss of control line
power. Control stations should be the
momentary type.
Stop-Start Control Module
(Accessory 49)
Stop-start three wire maintained control
is an arrangement used mostly when
controlling motors, but can be used in
lighting applications.
Any number of momentary contact
control stations consisting of normally
open start buttons and normally closed
stop buttons can be used. Start buttons
are connected in parallel and stop
buttons in series.
Operation (Magnetic Latch)
A permanent magnet is built into the
contactor structure of the 30A, 60A,
100A, and 200A contactors that will
maintain the contactor in its energized
state indefinitely without using control
power. When energized, a DC current is
applied that produces a magnetic field
that reinforces the polarity of the
permanent magnet, and the contactor
pulls in immediately. The current to the
coil is disconnected by the coil clearing
interlock. In order to drop out the
contactor, it is necessary to apply a field
through the OFF coil in the reverse
direction to the permanent magnet.
This momentarily cancels the magnetic
attraction and the contactor drops out.
Coil and module failures are possible
when used with solid state relays and
PLC outputs. 24-volt systems are ok to
use, but 120 volts and above should be
discouraged. If higher values cannot
be avoided, an interposing relay should
be used.
(Mechanically Latched)
The 300 & 400A lighting and heating
contactors operate using a latching
mechanism.
Closing – When the “close” pushbutton
is operated, the closing coil is energized,
closing the contactor. As the contactor
closes, the latch lever hooks over the
latch pin to mechanically latch the
contactor closed. The coil-clearing
auxiliary contact de-energizes the
closing coil.
Opening – When the “Trip” pushbutton
is operated, the trip solenoid coil is
energized, unhooking the latch lever
from the latch pin, which allows the
contactor to open. As the contactor
opens, the coil-clearing auxiliary contact
de-energizes the trip solenoid coil.
through control modules.
Siemens Industry, Inc.
Industrial Controls Catalog
Lighting Control
Mechanically and Magnetically Held Lighting Contactors, Class CLM
Selection
Ordering Information
왘
왘
왘
왘
왘
왘
Coil Table
Replace *** with a number from the coil table.
Field modification kits see page 8/82.
Factory modifications see page 8/95.
Dimensions see page 8/112 open page 8/129 enclosed.
Wiring Diagrams see page 8/147.
Replacement parts see page 8/160.
60Hz Voltage
Number
24
120
208
240
277
480
600
024
120
208
240
277
480
600
Open and Non-combination Enclosed Contactors
Open Type
Enclosure
NEMA 1
Max
Amp
Rating
20
30
60
100
200
300
400
NEMA 4/4X Stainless Steel
NEMA 12
NEMA 3/3R
General Purpose
Watertight, Dust-tight,
Corrosion Resistant,
304 Stainless Steel
Industrial Use
Weatherproof
Number
of Poles
2
3
4
6
8
10
12
2
3
4
5
6
8
9
10
12
2
3
4
5
6
8
9
10
12
2
3
4
5
2
3
4
5
2
3
2
3
Catalog Number
see table
below
CLM0C02***
CLM0C03***
CLM0C04***
CLM0C05***
CLM0C06***
CLM0C08***
CLM0C09***
CLM0C10***
CLM0C12***
CLM0D02***
CLM0D03***
CLM0D04***
CLM0D05***
CLM0D06***
CLM0D08***
CLM0D09***
CLM0D10***
CLM0D12***
CLM0E02***
CLM0E03***
CLM0E04***
CLM0E05***
CLM0F02***
CLM0F03***
CLM0F04***
CLM0F05***
CLM0G02***
CLM0G03***
CLM0H02***
CLM0H03***
List Price $ Catalog Number
CLM1B02***
CLM1B03***
CLM1B04***
CLM1B06***
CLM1B08***
CLM1B10***
CLM1B12***
CLM1C02***
CLM1C03***
CLM1C03***
CLM1C05***
CLM1C06***
CLM1C08***
CLM1C09***
CLM1C10***
CLM1C12***
CLM1D02***
CLM1D03***
CLM1D04***
CLM1D05***
CLM1D06***
CLM1D08***
CLM1D09***
CLM1D10***
CLM1D12***
CLM1E02***
CLM1E03***
CLM1E04***
CLM1E05***
CLM1F02***
CLM1F03***
CLM1F04***
CLM1F05***
CLM1G02***
CLM1G03***
CLM1H02***
CLM1H03***
List Price $
Catalog Number
CLM2B02***
CLM2B03***
CLM2B04***
CLM2B06***
CLM2B08***
CLM2B10***
CLM2B12***
CLM2C02***
CLM2C03***
CLM2C04***
CLM2C05***
CLM2C06***
CLM2C08***
CLM2C09***
CLM2C10***
CLM2C12***
CLM2D02***
CLM2D03***
CLM2D04***
CLM2D05***
CLM2D06***
CLM2D08***
CLM2D09***
CLM2D10***
CLM2D12***
CLM2E02***
CLM2E03***
CLM2E04***
CLM2E05***
CLM2F02***
CLM2F03***
CLM2F04***
CLM2F05***
CLM2G02***
CLM2G03***
CLM2H02***
CLM2H03***
List Price $
Catalog Number
CLMSB02***
CLMSB03***
CLMSB04***
CLMSB06***
CLMSB08***
CLMSB10***
CLMSB12***
CLMSC02***
CLMSC03***
CLMSC04***
CLMSC05***
—
—
—
—
—
CLMSD02***
CLMSD03***
CLMSD04***
CLMSD05***
—
—
—
—
—
CLMSE02***
CLMSE03***
CLMSE04***
CLMSE05***
CLMSF02***
CLMSF03***
CLMSF04***
CLMSF05***
—
—
—
—
List Price $
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Open 20 Amp Contactors
Max
Amp
Rating
20
110–120V Coil 50/60Hz
Number
of Poles
Catalog Number
2
3
4
6
8
10
12
CLM22031
CLM32031
CLM42031
CLM62031
CLM82031
CLM102031
CLM122031
Contactors
208–240V Coil 50/60Hz
List Price $ Catalog Number
with 2–6-poles will be assembled with all
poles located in the top portion of the contactor.
Contactors with 8–12-poles will be assembled with 6poles in the top portion and the remaining poles in
the bottom portion of the contactor.
Siemens Industry, Inc.
Industrial Controls Catalog
265–277V Coil 50/60Hz
List Price $ Catalog Number
CLM22061
CLM32061
CLM42061
CLM62061
CLM82061
CLM102061
CLM122061
24
List Price $ Catalog Number
CLM22071
CLM32071
CLM42071
CLM62071
CLM82071
CLM102071
CLM122071
volt coils are not available on 20, 300 and 400 amp
contactor sizes. For 24 volt control of 20 amp contactor
select solid state control module.
For conduit hubs and conversion instructions, see
page 8/88.
Product Category: NEMA
440–480V Coil 50/60Hz
List Price $
CLM22091
CLM32091
CLM42091
CLM62091
CLM82091
CLM102091
CLM122091
CLM
30 & 60A 6-12-pole can be field assembled.
Order mounting kit 49MCMPMA and the appropriate
number of 2-5 pole contactors.
600 volt coils are not available on 20 amp
contactors.
8/73
Lighting Control
Combination Mechanically and Magnetically Held Lighting Contactors, Class CLM
Selection
Ordering Information
왘
왘
왘
왘
왘
왘
Coil Table
Replace *** with a number from the coil table.
Field modification kits see page 8/82.
Factory modifications see page 8/95.
Dimensions see page 8/129.
Wiring Diagrams see page 8/147.
Replacement parts see page 8/160.
60Hz Voltage
Number
24
120
208
240
277
480
600
024
120
208
240
277
480
600
Combination Lighting Contactors
Enclosure
NEMA 12, NEMA 3/3R
NEMA 4 Painted (thru 100 amps)
NEMA 1
General Purpose
Disconnect
Type
Non-Fusible
Contactor
Amp
Rating
Number
of NO
Poles
20
30
60
100
200
300
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
20
30
60
Fusible
100
200
300
20
30
60
100
200
300
Circuit
Breaker
Disc
Amp
Rating
Disc Amp/
Fuse Clip
Rating
30A
30A
60A
100A
200A
400A
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
30A/250V
30A/600V
30A/250V
30A/600V
60A/250V
60A/600V
100A/250V
100A/600V
200A/250V
200A/600V
400A/250V
400A/600V
—
—
—
—
—
—
Circuit
Breaker
Rating Catalog Number List Price $
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
20A
30A
60A
100A
200A
300A
CMNB14***
CMNC14***
CMND15***
CMNE16***
CMNF17***
CMNG18***
CMFB10***
CMFB11***
CMFC10***
CMFC11***
CMFD12***
CMFD13***
CMFE14***
CMFE15***
CMFF16***
CMFF17***
CMFG18***
CMFG19***
CMBB14***
CMBC15***
CMBD18***
CMBE18***
CMBF10***
CMBG11***
NEMA 4/4X Stainless Steel
Industrial Use
Weatherproof, Watertight, Dust-tight
Watertight, Dust-tight,
Corrosion Resistant,
304 Stainless Steel
Catalog Number
Catalog Number
List Price $
CMNB24***
CMNC24***
CMND25***
CMNE26***
CMNF27***
CMNG28***
CMFB20***
CMFB21***
CMFC20***
CMFC21***
CMFD22***
CMFD23***
CMFE24***
CMFE25***
CMFF26***
CMFF27***
CMFG28***
CMFG29***
CMBB24***
CMBC25***
CMBD28***
CMBE28***
CMBF20***
CMBG21***
List Price $
CMNBS4***
CMNCS4***
CMNDS5***
CMNES6***
CMNFS7***
CMNGS8***
CMFBS0***
CMFBS1***
CMFCS0***
CMFCS1***
CMFDS2***
CMFDS3***
CMFES4***
CMFES5***
CMFFS6***
CMFFS7***
CMFGS8***
CMFGS9***
CMBBS4***
CMBCS5***
CMBDS8***
CMBES8***
CMBFS0***
CMBGS1***
Lighting & Heating Contactor Ratings CLM
Maximum AC/DC Voltage and
Amp Ratings
Load
Type
Poles to Load
Amperes
2 for 1-Phase
Continuous 1 for 1-Phase 3 for 3-Phase
Tungsten
Ballast
General
General
20
20
30
20
250V AC
347V AC
347V AC
125V DC
250V AC
600V AC
600V AC
250V DC
Contactor Ratings
Load
Amperes
Max Volts
Type
Continuous Line to Line
Tungsten
Ballast
Heating
30-400
30-400
30-400
Max Volts
Line to Neutral
480
600
600
277
346
346
Inrush Current Over Fuse Size (amps RMS)
at AC Control Voltage 20A CLM
Amps
Inrush
Fuse
24
120V
5.0
2.0
240V
2.5
1.0
277V
2.2
1.0
347V
1.8
0.75
Inrush VA
Dropout VA
20
30
60
60
100/200
100/200
300/400
625
410
410
600
900
1300
1600
6
40
40
40
200
130
550
2-12
2-5
2-3
4-5
2-3
4-5
2-3
480V
1.3
0.5
volt coils are not available on 20 and 300 amp
contactors. Use solid state control module on 20 amp
size.
8/74
AC Coil Data
Contactor
Amperes
No. Poles
For
conduit hubs and conversion instructions, see
page 8/88.
Product Category: NEMA
600
volt coils are not available on 20 amp
contactors.
Siemens Industry, Inc.
Industrial Controls Catalog
Industrial Control Power Transformers
Class MT
General
Features
▪ Epoxy-encapsulated (50–5000VA);
Completely seals the transformer coils
against moisture, dust, dirt and
industrial contaminants for maximum
protection in hostile and industrial
environments
▪ Fuse clips (most models). Factory
mounted for integral fusing on the
secondary side to save panel space,
save wiring time and save the cost
of buying an add-on fuse block or kit
▪ Integrally molded barriers. Between
terminals and transformer, protect
against electrical creepage. Up to 30%
greater terminal contact area permits
low-loss connections. Extra-deep barriers reduce the chance of shorts from
frayed leads or careless wiring
▪ Terminals. Molded into the
transformer, are difficult to break during wiring. A full quarter-inch of
thread on the 10-32 terminal screws
prevents stripping and pullout
▪ Jumpers supplied. Two jumper links
are standard with all transformers
which can be wired for dual primary
voltages
Operation
Industrial control circuits and motor
control loads typically require more
current when they are initially energized
than under normal operating conditions.
This period of high current demand,
referred to as inrush, may be as great
as ten times the current required under
steady state (normal) operating
conditions, and can last up to 40
milliseconds. A transformer in a circuit
subject to inrush will typically attempt
to provide the load with the required
current during the inrush period.
However, it will be at
the expense of the secondary voltage
stability by allowing the voltage to
the load to decrease as the current
increases. This period of secondary
voltage instability, resulting from
increased current, can be of such
magnitude that the transformer is
unable to supply sufficient voltage to
energize the load. The transformer
must therefore be designed and
constructed to accommodate the high
inrush current, while maintaining
secondary voltage stability. According
to NEMA standards, the secondary
voltage would typically be
at 85% of the rated voltage.
Siemens Industry, Inc.
Industrial Controls Catalog
Industrial Control Power Transformers
are specifically designed and built to
provide adequate voltage to the load
while accommodating the high current
levels present at inrush. These
transformers deliver excellent
secondary voltage regulation and meet
or exceed the standards established
by NEMA, ANSI, UL and CSA. Their
rugged construction and excellent
electrical characteristics ensure reliable
operation of electromagnetic devices
and trouble-free performance.
Specifications
▪ Laminations are built with silicon
steel to minimize core losses and
to increase optimum performance
and efficiency
▪ Copper magnet wire of the highest
quality assures efficient operation
▪ Factory mounted type “K” fuse
clips are standard on all secondary
transformers where possible
▪ Two jumper links are standard with
all transformers which can be wired
for dual primary voltages
▪ UL listed and CSA certified
▪ 50/60 Hz rated
▪ Insulation materials are of the
highest rating available for the
temperature class
▪ Mounting brackets are heavy
gauge steel to add strength to core
construction and provide stable
mounting. Slotted mounting feet
permit easy installation
▪ Attractive black finish; easy-to-read
nameplate with complete rating data
and wiring diagram
▪ Class 105°C (221°F) insulation
system. 55°C (131°F) temperature
rise. (50 – 750VA typical)
▪ Class 180°C (356°F) insulation
system. 120°C (248°F) temperature
rise. (1000 – 5000VA typical)
▪ Optional field mounted 2-pole
primary Class CC fuse block is
available
8/75
Industrial Control Power Transformers
Class MTG
General
the covers prevent contact with current carrying parts on
the transformer and are available for 4 terminal configurations.
The international fuse block kits have inherent touch
safe terminals and fuse clips.
Siemens Meets International Standards
CSA (Canadian Standards Association) was utilized as a
Competent Body in reviewing, interpreting and properly
complying with the requirements of IEC-742 to place a CE
mark on its MTG Series product. As a National Certification
Body, CSA also has the proper documentation and reports
on file for MTG Series to utilize the CB Scheme ensuring
acceptance throughout the world.
The standard Siemens MTG product is available with terminal
covers which meets the requirements of IEC-529, IP20
degree of protection and meets the applicable requirements
for covers per IEC-742.
Features
▪ Class MTG Industrial Control Transformers are 100%
certified for all domestic and International Applications
▪ The MTG line has full compliance with IEC Safety
standards EN 61 558
▪ CE Mark in accordance with requirements for EN 61 558
▪ Meets IP-20 specifications per IEC 529 for finger-safe
protection when used with Siemens Touch Safe snap
on terminal cover kits. Meets IP-00 specifications when
covers are not used.
▪ UL Listed (File # E46323)
▪ CSA Certified (File #LR27533)
▪ Exceeds applicable requirements for control transformers as
determined by NEMA and ANSI
▪ Insulation requirements is twice that of UL506
▪ Proven Epoxy-encapsulated coils operate cooler and
completely seal the transformer coils against moisture,
dust, dirt and industrial contaminants for maximum
protection in hostile and industrial environments
▪ Available in 50 to 750 VA sizes, in all standard voltage
combinations
▪ Class 105°C (221°F) insulation system. 55°C (131°F)
temperature rise. (50 –750VA typical)
▪ Class 180°C (356°F) insulation system. 120°C (248°F)
temperature rise. (1000–5000VA typical)
▪ Primary and secondary fusing capability available as field
installed kits for domestic or international fusing
▪ Integrally-molded terminals and barriers between terminals
make breakage virtually impossible during wiring. The MTG
transformer construction is the same as our high quality
Class MT transformers
Optional Field Installed Fuse Clip Kits For Panel Mounting
▪ 2-Pole primary Class CC fuse block
13
1
▪ 1-Pole secondary midget fuse block for ⁄32 ҂ 1 ⁄2 fuses
▪ 2-Pole primary international type fuse blocks
▪ 1-Pole secondary international type fuse blocks
Optional Touch-Safe Snap-On Terminal Cover Kits
The Touch-Safe terminal covers are designed to comply
with IEC 742 and IP 20 requirements. When installed,
8/76
IEC-742
The requirements for industrial control circuit transformers
to be used in the European Common Market are identified
by the International Electrotechnical Commission (IEC) and
specified under IEC-742, Non-Short Circuit Proof Isolating
Transformers, under the Low Voltage Directive 73/23/EEC.
Manufacturers of control transformers indicate compliance
with these requirements by placing a CE mark on the
product.
▪ Winding to winding insulation requirements may be twice
that for IEC-742 compared to UL506
▪ The electrical clearances between current carrying parts
are one-third greater to comply with IEC-742 requirements
for units up to 250VA with voltages up to 440 volts ac
▪ Transformers manufactured to IEC-742 requirements
will have a minimum of 10% higher overload capacity
than those manufactured only to UL506 requirements
While no requirement exists in IEC-742 for the electrical
connections to be either finger safe or touch proof, the
specification does state that IF a transformer is supplied
with a cover to prevent incidental contact with current
carrying parts, that cover must utilize two separate methods
or places of securing it to the component, with neither being
dependent upon the other. Additionally, one of these methods
MUST require a tool to remove it.
IEC-529
The requirements for finger-safe or touch-proof electrical
connections are identified by the International Electrotechnical
Commission (IEC) under specification 529, Classification of
Degrees of Protection Provided by Enclosures. These various
degrees of protection are identified and differentiated by IP
ratings.
The IP specification which most closely approximates
protection to a human finger is IP20. This IP rating would
be the most common degree of touch-proof connection
for electrical components such as transformers.
EN 61 558
The requirements for industrial control transformers to be
used in the European Common Market are identified
by the IEC and specified in EN 61 558, Safety of Power
Control Transformers, under Low Voltage Directive 73/23/EEC.
CE mark on the product indicates compliance.
Siemens Industry, Inc.
Industrial Controls Catalog
Industrial Control Power Transformers
Class MT, MTG
General
Transformer Selection Process
Selecting a transformer for industrial
control circuit applications requires
knowledge of the following terms:
Inrush VA is the product of load voltage (V) multiplied by the current (A) that
is required during circuit start-up. It
is calculated by adding the inrush VA
requirements of all devices (contactors,
timers, relays, pilot lights, solenoids,
etc.), which will be energized together.
Inrush VA requirements are best
obtained from the component
manufacturer.
Sealed VA is the product of load
voltage (V) multiplied by the current (A)
that is required to operate the circuit
after initial start-up or under normal
operating conditions. It is calculated by
adding the sealed VA requirements of
all electrical components of the circuit
that will be energized at any given
time. Sealed VA requirements are
best obtained from the component
manufacturer. Sealed VA is also referred
to as steady state VA.
Primary Voltage is the voltage available from the electrical distribution system and its operational frequency,
which is connected to the transformer
supply voltage terminals.
Secondary Voltage is the voltage
required for load operation which is
connected to the transformer load
voltage terminals.
Once the circuit variables have been determined, transformer selection is a simple
5-step process as follows:
1. Determine the Application Inrush VA by using the following industry accepted formula:
——————————–
Application Inrush VA = √(Inrush VA)2 ѿ (Sealed VA)2
2. Refer to the Regulation Data Chart. If the primary voltage is basically stable and
does not vary by more than 5% from nominal, the 90% secondary voltage column
should be used. If the primary voltage varies between 5% and 10% of nominal,
the 95% secondary voltage column should be used.
3. After determining the proper secondary voltage column, read down until a value
equal to or greater than the Application Inrush VA is found. In no case should a
figure less than the Application Inrush VA be used.
4. Read left to the Transformer VA Rating column to determine the proper
transformer for this application. As a final check, make sure that the Transformer
VA Rating is equal to or greater than the total sealed requirements. If not, select
a transformer with a VA rating equal to or greater than the total sealed VA.
5. Refer to the following pages to determine the proper catalog number based
on the transformer VA, and primary and secondary voltage requirements.
Regulation Data Chart
Transformer
VA Ratings
Inrush VA At 20% Power Factor
NEMA/IEC
NEMA/IEC
95% Sec
90% Sec
Voltage
Voltage
NEMA/IEC
85% Sec
Voltage
25
50
75
100
150
200
250
300
350
500
750
1000
1000
1500
2000
3000
5000
100/–––
170/190
310/350
370/410
780/860
810/900
1400/1540
1900/2090
3100/3410
4000/4400
8300/9130
15000/–––
9000/–––
10500/–––
17000/–––
24000/–––
55000/–––
150/–––
240/270
540/600
730/810
1150/1270
1450/1600
2300/2530
3850/4240
4800/5280
7000/7700
14000/15400
27000/–––
18500/–––
205000/–––
34000/–––
47500/–––
115000/–––
130/–––
200/220
410/460
540/600
930/1030
1150/1270
1900/2090
2700/2970
3650/4020
5300/5830
11000/12100
21000/–––
13000/–––
15000/–––
25500/–––
36000/–––
92500/–––
To comply with NEMA standards, which require all magnetic devices to operate successfully at 85% of rated voltage, the
90% secondary voltage column is most often used in selecting a transformer.
For
For
units with Class 105°C insulation systems.
units with Class 180°C insulation systems.
Fuse Clip Kit KCCFPX2R
Primary Fuse Kit
In addition to factory installed secondary fusing, Siemens offers a primary
fuse kit for class MT transformers size
50–750 VA for field installation. The
primary fuse kit includes a 2-pole Class
CC fuse block, instructions and all
associated mounting and wiring
hardware. Additionally, this fuse kit
will fit most competitors’ units. To
order this kit, use catalog number
KCCFPX2R. The primary fuse kit,
when installed, will add a maximum of
0.69 in. (18 mm) to the transformer “A”
dimension and 1.94 in. (49 mm) to the
“C” dimension.
Siemens Industry, Inc.
Industrial Controls Catalog
Primary Fuse Kit Installation—Class MT Transformer with Primary Fuse Kit, KCCFPX2R
8/77
Industrial Control Power Transformers
Domestic, Class MT
Selection
Ordering Information
왘
왘
왘
왘
Voltage Table
Use the Voltage Table to determine the
primary and secondary voltage required.
Field Modifications see page 8/90.
Dimensions see page 8/114.
Wiring Diagrams see page 8/149.
Primary Volts 50/60 Hz
Secondary Volts
240 X 480, 230 X 460, 220 X 440
240 X 480
120 X 240
115 X 230
550/575/600
208/277
208/230/460
230/460/575
380/400/415
208/230/460, 200/220/440,240/480
240/416/480/600, 230/400/460/575,
220/380/440/550, 208/500
240 X 480
120/115/110
24
24
24
110/115/120
120
115
95/115
110 X 220
24 X 115, 23 X 110, 25 X 120
99/120/130, 95/115/125,
91/110/120, 85/100/110
120 X 240
VA
Rating
Voltage Letter
A
Voltage Letter
B
Voltage Letter
C
Voltage Letter
D
Voltage Letter
E
Catalog No
Catalog No
Catalog No
Catalog No
Catalog No
50
75
100
150
200
250
300
350
500
750
1000
1500
2000
3000
5000
MT0050A
MT0075A
MT0100A
MT0150A
MT0200A
MT0250A
MT0300A
MT0350A
MT0500A
MT0750A
MT1000A
MT1500A
MT2000A
MT3000A
MT5000A
MT0050B
MT0075B
MT0100B
MT0150B
MT0200B
MT0250B
MT0300B
MT0350B
MT0500B
MT0750B
—
—
—
—
—
Voltage Letter
G
Voltage Letter
H
Voltage Letter
I
Catalog No
Catalog No
VA
Rating
Catalog No
50
75
100
150
200
250
300
350
500
750
1000
1500
2000
3000
5000
MT0050G
MT0075G
MT0100G
MT0150G
MT0200G
MT0250G
MT0300G
MT0350G
MT0500G
MT0750G
MT1000G
MT1500G
MT2000G
MT3000G
MT5000G
Includes
A 2-pole
List Price $
List Price $
List Price $
—
—
—
—
—
List Price $
MT0050H
MT0075H
MT0100H
MT0150H
MT0200H
MT0250H
MT0300H
MT0350H
MT0500H
MT0750H
MT1000H
MT1500H
MT2000H
MT3000H
MT5000H
secondary fuse clip on sizes 50–750VA.
primary Class CC fuse kit is available for field
installation. See page 8/77 for details. Catalog Number:
KCCFPX2R.
8/78
—
List Price $
MT0050C
MT0075C
MT0100C
MT0150C
MT0200C
MT0250C
MT0300C
MT0350C
MT0500C
—
—
—
—
—
—
MT0050I
MT0075I
MT0100I
MT0150I
MT0200I
MT0250I
MT0300I
MT0350I
MT0500I
MT0750I
MT1000I
MT1500I
MT2000I
MT3000I
—
—
—
—
—
—
—
List Price $
—
List Price $
MT0050D
MT0075D
MT0100D
MT0150D
MT0200D
MT0250D
MT0300D
MT0350D
MT0500D
—
—
—
—
—
—
—
—
—
—
—
—
A
B
C
D
E
F
G
H
I
J
L
M
Voltage Letter
F
List Price $
MT0050E
MT0075E
MT0100E
MT0150E
MT0200E
MT0250E
MT0300E
MT0350E
MT0500E
MT0750E
MT1000E
—
—
—
—
Letter
—
—
—
—
Catalog No
List Price $
MT0050F
MT0075F
MT0100F
MT0150F
MT0200F
MT0250F
MT0300F
MT0350F
MT0500F
MT0750F
—
—
—
—
—
—
—
—
—
—
Voltage Letter
J
Voltage Letter
L
Voltage Letter
M
Catalog No
Catalog No
Catalog No
List Price $
MT0050J
MT0075J
MT0100J
MT0150J
MT0200J
MT0250J
MT0300J
MT0350J
MT0500J
—
—
—
—
—
—
—
—
—
—
—
—
MT0050L
—
MT0100L
MT0150L
—
MT0250L
—
MT0350L
MT0500L
MT0750L
—
—
—
—
—
List Price $
—
—
—
—
—
—
—
—
MT0050M
MT0075M
MT0100M
MT0150M
MT0200M
MT0250M
MT0300M
MT0350M
MT0500M
MT0750M
—
—
—
—
—
List Price $
—
—
—
—
—
Includes secondary fuse clip on sizes 50–500VA.
Does not include secondary fuse clip on any size.
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Industrial Control Power Transformers
International, Class MTG
Selection
Ordering Information
왘
왘
왘
왘
VA
Rating
50
75
100
150
200
250
300
350
500
750
1000
1500
2000
3000
5000
Use the Voltage Table to determine
the primary and secondary voltage
required.
Field Modifications see page 8/90.
Dimensions see page 8/114.
Wiring Diagrams see page 8/149.
Voltage Letter
A
Voltage Letter
B
Catalog No
Catalog No
List Price $ Catalog No
MTG0050B
MTG0075B
MTG0100B
MTG0150B
MTG0200B
MTG0250B
MTG0300B
MTG0350B
MTG0500B
MTG0750B
MTG1000B
—
—
—
—
MTG0050C
MTG0075C
MTG0100C
MTG0150C
MTG0200C
MTG0250C
MTG0300C
MTG0350C
MTG0500C
MTG0750C
MTG1000C
—
—
—
—
List Price $
MTG0050A
MTG0075A
MTG0100A
MTG0150A
MTG0200A
MTG0250A
MTG0300A
MTG0350A
MTG0500A
MTG0750A
MTG1000A
MTG1500A
MTG2000A
MTG3000A
MTG5000A
Siemens Industry, Inc.
Industrial Controls Catalog
Voltage Table
Voltage Letter
C
—
—
—
—
Primary Volts 50/60 Hz
Secondary Volts
240 X 480, 230 X 460, 220 X 440
240 X 480
120 X 240
550/575/600
380/400/415
208/230/460, 200/220/440, 240/480
380
120/115/110
24
24
110/115/120
110 X 220
24 X 115, 23 X 110, 25 X 120
24
Voltage Letter
E
List Price $
—
—
—
—
—
Catalog No
MTG0050E
MTG0075E
MTG0100E
MTG0150E
MTG0200E
MTG0250E
MTG0300E
MTG0350E
MTG0500E
MTG0750E
—
—
—
—
—
Voltage Letter
I
List Price $ Catalog No
—
—
—
—
—
Product Category: NEMA
MTG0050I
MTG0075I
MTG0100I
MTG0150I
MTG0200I
MTG0250I
MTG0300I
MTG0350I
MTG0500I
MTG0750I
—
—
—
—
—
Letter
A
B
C
E
I
J
P
Voltage Letter
J
Voltage Letter
P
List Price $
Catalog No
Catalog No
—
—
—
—
—
MTG0050J
MTG0075J
MTG0100J
MTG0150J
MTG0200J
MTG0250J
MTG0300J
MTG0350J
MTG0500J
MTG0750J
MTG1000J
—
—
—
—
List Price $
—
—
—
—
MTG0050P
MTG0075P
MTG0100P
MTG0150P
MTG0200P
MTG0250P
MTG0300P
MTG0350P
MTG0500P
MTG0750P
—
—
—
—
—
List Price $
—
—
—
—
—
8/79
Field Modification Kits
Class SMF, MMS, MRS
Selection
Accessories—Class SMF
Accessories—Class MMS, MRS
Description
Catalog
Number
Handle Guard Kit with Padlock Provision
Emergency Off Actuator
Additional Key for Key Operated Devices
SMFFL1
SMFPB1
SMFFK1
List
Price $
Pilot Light Kits—Class MMS, MRS
Device
Class SMF
Voltage
Rating
115–277V AC
SMFFL1
SMFPB1
SMFFK1
Voltage
Rating
Catalog Number List Price $ Catalog Number List Price $
Device
SMFPL10
110–120V AC
Class MMS 208–277V AC
440–600V AC
SMFPL10G
List
Price $
Red
Pilot Light
Green
Pilot Light
Catalog Number List Price $ Catalog Number List Price $
SMFPL11
SMFPL12
SMFPL13
SMFPL11G
SMFPL12G
SMFPL13G
Enclosures—Class MMS
For Use With SMF
Standard Size
NEMA 1
General Purpose
FO1, FO1P, FO2, FO2P, FO3,
FO3P, FO4, FO4P
Oversized
NEMA Type 1
General Purpose
FO1, FO1P, FO2, FO2P, FO3,
FO3P, FO4, FO4P
NEMA 3R, 4, 12
Watertight
Dust-tight
FO1, FO1P, FO2, FO2P, FO3,
FO3P, FO4, FO4P
Catalog
Number
List
Price $
SMFFE2
SMFFE1
SMF40BC1
Nameplates—Class SMF
Enclosure Type
For Use With MMS
Standard Size
NEMA 1
General Purpose
Oversized
NEMA Type 1
General Purpose
Jumbo
NEMA Type 1
General Purpose
NEMA 3R, 4, 12
Watertight
Dust-tight
KO1, KO1P, KO1B, KO2,
KO2A, KO2B, KO3, KO3A,
KO3B, KO4, KO4A, KO4B
KO1, KO2B, KO2C, KO3,
KO3A, KO3B, KO4, KO4B,
KO4C, KO2
KO1, KO2B, KO2C, KO3,
KO3A, KO3B, KO4, KO4B,
KO4C, KO2
KO1, KO2B, KO2C, KO3,
KO3A, KO3B, KO4, KO4B,
KO4C
Catalog
Number
List
Price $
MMSKE3
SMFKE1
SMFKE2
SMF40BC1
Nameplates—Class MMS
Without
Pilot Light
Nameplate Catalog
Marking
Number
With
Pilot Light
List
Price $
Catalog
Number
None
SMFFN2
—
None
SMFFSN3
SMFFSN4
NEMA 1
None
surface mounted enclosure High
or gray flush plate
Low
SMFFN30
SMFFN31
SMFFN32
SMFFN40
SMFFN41
SMFFN42
Stainless Steel Plate
Handle Guard Kit with Padlock Provision
Emergency Off Actuator
Additional Key for Key Operated Devices
Green
Pilot Light
Enclosure Type
Standard
commercial switch box
cover including
stainless steel plates
Catalog Number
Pilot Light Kits—Class MMS, MRS
Red
Pilot Light
Enclosures—Class SMF
For Use On
Description
Without
Pilot Light
List
Price $
—
For Use On
Standard
commercial switch box
cover including
stainless steel plates
NEMA 1
surface mounted
enclosure or
gray flush plate
Nameplate Catalog
Marking
Number
With
Pilot Light
List
Price $
Catalog
Number
List
Price $
—
None
SMFFN1
—
None
High
Low
Forward
Reverse
SMFFN10
SMFFN11
SMFFN12
SMFFN13
SMFFN14
SMFFN20
SMFFN21
SMFFN22
—
SMFFN24
—
Replacement Parts—Class SMF, MMS
Description
Catalog Number
Replacement Toggle Kits:Type FW and KW (NEMA 4 Metallic Enclosure)
SMFHW1
List
Price $
Pilot
lights can be field installed on standard NEMA 1
general purpose surface mount enclosures, and
NEMA 3R, 4 and 12 enclosures only.
For flush mounting units a complete switch unit with
pilot light must be ordered.
8/80
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Field Modification Kits
Class 11 - 3RV
Selection
Description
Type
Catalog Number
1 SPDT contact, NO/NC
1 NO ѿ 1 NC
1 SPDT contact NO/NC electronic contact
1 NO ѿ 1 NC
2 NO
2 NC
2 NO ѿ 2 NC
3RV1901-1D
3RV1901-1E
3RV1901-1G
3RV1901-1A
3RV1901-1B
3RV1901-1C
3RV1901-1J
1NO + 1NC for any trip
+
1NO + 1NC for short
circuit trip only.
3RV1921-1M
List Price $
Auxiliary Contact Blocks
3RV1901-1D
3RV1901-1A
3RV1912-1CP0
Plug in contact block
1 block per 3RV
mountable at the front
Side mount auxiliary
contact with
screw connection
1 side mount auxiliary
contact per 3RV mountable
on the left-hand side
Signaling Contact Block
Signaling contact
1 signaling contact per 3RV
mountable on the left-hand
side. Can also be fitted
together with side mount
auxiliary contact.
Auxiliary Releases
Undervoltage release
1 undervoltage release
per 3RV mountable on the
right-hand side.
Cannot be fitted together
with shunt trip.
Undervoltage release
with early make contacts (2NO)
1 undervoltage release
per 3RV mountable at
the right-hand side.
Cannot be fitted together
with shunt trip.
Shunt trip
1 shunt trip per 3RV
mountable at the righthand side. Cannot be
fitted together with
undervoltage release.
Pilot Lights
For NEMA 1 enclosure only. Kit
includes Red, Green, and
Amber lenses
3RV1902-1DP0
AC 50Hz
—
230V
415V
AC 60Hz
120V
208V
240V
480V
3RV1902-1AF0
3RV1902-1AM1
3RV1902-1AP0
3RV1902-1AV1
AC 50Hz
230V
415V
AC 60Hz
240V
480V
3RV1922-1CP0
3RV1922-1CV1
AC 50Hz/60Hz
20–24V
90–110V
200–240V
350–415V
DC
20–70V
70–190V
190–330V
330–500V
3RV1902-1DB0
3RV1902-1DF0
3RV1902-1DP0
3RV1902-1DV0
AC 50Hz/60Hz
24V
120V
240V
480V
600V
49SBLBJ
49SBLBF
49SBLBG
49SBLBH
49SBLBE
For 3RV with amp range:
0.11-22A up to 480V Max. 0.11-12.5A up to
575V Max
3RV1928-1H
Four mounting holes required for each 3RV.
3RB1900-0B
For sealing the FLA
adjustment dial
(Kit includes 10 covers)
3RV1908-0P
For sealing the front mount
auxiliary opening. (Kit includes 10 covers)
3RV1901-0H
Lug Kit
Required for Type E Manual
Combination Starter
Mounting
Push-in Mounting Hole Kit
For screw panel mounting
of the 3RV
Sealing device
3RV1928-1H
Adjustment Dial covers
Front mount auxiliary cover
Door Operators
3RV1901-0H
100% on time.
5 sec. max. on time.
Product Category: PILO.
Siemens Industry, Inc.
Industrial Controls Catalog
Thru-the-door operators
Rotary operating mechanism, rated
NEMA 12, lockable with up to
3 padlocks in the OFF position.
Includes extension shift and
connecting element for the 3RV.
130 mm depth
3RV1926-0B
330 mm depth with
supporting bracket
3RV1926-0K
With Black Handle
Compatible
for use in dusty atmospheres. Contacts
rated for 1-300mA @ 3-60V.
Product Category: IEC
8/81
Field Modification Kits
Pilot Devices
Selection
Push Buttons and
Selector Switches
Class
Enclosure
Type
Controller Size or
(Lighting Rating)
Open
00-4
00-4 or (20–100A)
49SBPB5
14, 40, LEN, CLM
1
5-8 or (200–400A)
49SBSB1
22, 43
30 (2S1W)
00-8 or (20–400A)
Open
00-4
00-4
1
5-8
12, 4/4X
0-8
Open
0-4
0-1 3⁄4
1
2-4
12, 4/4X
0-4
Open
1
0-4
0-4
12, 4/4X
0-4
17, 18, 36, 37, 83, 84,
LED,LEF, LEB, CMN ,
CMF , CMB
1, 12, 4/4X
0-8 (20-400A)
25, 26
1, 12, 4/4X
0-8
32
1, 12, 4/4X
0-4
49SAP05
30 (2S2W)
49SAS01
12, 4/4X
Type
Catalog
Number
Start, Stop Push Buttons
Hand-Off-Auto Selector Switch
Off-On Selector Switch
Start, Stop Push Buttons
Hand-Off-Auto Selector Switch
Off-On Selector Switch
Start, Stop Push Buttons
Hand-Off-Auto Selector Switch
Keyed Hand-Off-Auto (key removable in all positions)
Off-On Selector Switch
Start, Stop Push Buttons
Hand-Off-Auto Selector Switch
Keyed Hand-Off-Auto (key removable in all positions)
Off-On Selector Switch
Forward-Off-Reverse Selector Switch
Forward-Off-Reverse Selector Switch
Forward, Reverse, Stop Push Buttons
Forward-Off-Reverse Selector Switch
Forward, Reverse, Stop Push Buttons
Forward-Off-Reverse Selector Switch
High-Off-Low Selector Switch
High-Off-Low Selector Switch
High, Low, Stop Push Buttons
High-Off-Low Selector Switch
High, Low, Stop Push Buttons
High-Off-Low Selector Switch
High-Off-Low Selector Switch
High-Off-Low Selector Switch
High, Low, Stop Push Buttons
High-Off-Low Selector Switch
Start, Stop Push Buttons
Hand-Off-Auto Selector Switch
Keyed Hand-Off-Auto (key removable in all positions)
Off-On Selector Switch
Forward, Reverse, Stop Push Buttons
Forward-Off-Reverse Selector Switch
High, Low, Stop Push Buttons
High-Off-Low Selector Switch
49SAPB5
49SASB1
49SASB4
49SBPB5
49SBSB1
49SBSB4
49SAP05
49SAS01
49SAS09
49SAS04
49SAP05
49SAS01
49SAS09
49SAS04
49SASB2
49SBSB2
49SAP02
49SAS02
49SAP02
49SAS02
49SASB3
49SBSB3
49SAP03
49SAS03
49SAP03
49SAS03
49SASB3
49SBSB3
49SAP03
49SAS03
49SAP05
49SAS01
49SAS09
49SAS04
49SAP02
49SAS02
49SAP03
49SAS03
List
Price $
To
be used for replacement of switch only. Does not
include relay or extra contact block on 30-400A CLM
and CM Lighting Contactors. Class 49SB not available
for these devices.
8/82
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Field Modification Kits
NEMA, Lighting and Heating Contactors, 20 Amp CLM, CMB, CMF, CMN
Selection
Solid State Control Module Kits For Lighting and Heating Contactors
CLM 20 Amp
Contactor Kit
Description
120V AC, 50/60 Hz
24V AC/DC,
50/60 Hz
240/277V AC,
50/60 Hz
12V AC/DC,
50/60 Hz
Accessory
Catalog
Number
List
Price $
Accessory
CLM4379771
47
(2-Wire Control)
(2W)
Catalog
Number
List
Price $
Accessory
CLM4379781
CLM4379772
48
(3-Wire Control)
(3W)
CLM4379773
CLM4379774
CLM4379782
CLM4379783
Catalog
Number
List
Price $
CLM4379791
49
(Start/Stop Control)
(3WS)
CLM4379784
CLM4379792
CLM4379793
CLM4379794
Protective Shielding for NEMA Products
Class 14
Class 40
Disconnect with protective shield
Class 14, 22, 30, 40, 43
Contactor or
Starter Size
Contactor Shield
Catalog Number
Starter Shield
Catalog Number
00–13⁄4
List Price $
2–21⁄2
List Price $
3–31⁄2
List Price $
4
49PSC1
49PSC2
49PSC3
49PSC4
49PSS1
49PSS2
49PSS3
49PSS4
List Price $
Class 17, 25, 32, 87
Disconnect
Size
Catalog
Number
30A
60 & 100A
200A
49PSD5
49PSD6
49PSD7
List Price $
These
kits are only for use with 20A mechanically held
lighting contactors.
Siemens Industry, Inc.
Industrial Controls Catalog
Product Category: NEMA
8/83
Field Modification Kits
Pilot Lights
Selection
Description
Enclosure
Type
Class
1
Controller Size or
(Lighting Rating)
00–4 or (20–200A)
Lens Color(s)
Legend(s)
Voltage
Catalog
Number
Red, Green, Amber
ON, RUN, OFF ,
OL TRIPPED ,
FORWARD, REVERSE,
LOW, HIGH
Red
(Transformer Type)
ON
Green
(Transformer Type)
OFF
Red, Green, Amber
ON, RUN, OFF ,
OL TRIPPED ,
FORWARD, REVERSE,
LOW, HIGH
Red
(Transformer Type)
ON
Green
(Transformer Type)
OFF
Red
(Transformer Type)
ON
Green
(Transformer Type)
OFF
24 Vac
120 Vac
208/240/277 Vac
480 Vac
600 Vac
24 Vac (Full Voltage)
120 Vac
240 Vac
480 Vac
600 Vac
24 Vac (Full Voltage)
120 Vac
240 Vac
480 Vac
600 Vac
24 Vac
120 Vac
208/240/277 Vac
480 Vac
600 Vac
24 Vac (Full Voltage)
120 Vac
240 Vac
480 Vac
600 Vac
24 Vac (Full Voltage)
120 Vac
240 Vac
480 Vac
600 Vac
24 Vac (Full Voltage)
120 Vac
240 Vac
480 Vac
600 Vac
24 Vac (Full Voltage)
120 Vac
240 Vac
480 Vac
600 Vac
49SBLBJ
49SBLBF
49SBLBG
49SBLBH
49SBLBE
49SPL0BRJ
49SPL0BRF
49SPL0BRG
49SPL0BRH
49SPL0BRE
49SPL0AGJ
49SPL0AGF
49SPL0AGG
49SPL0AGH
49SPL0AGE
49SBLBJ
49SBLBF
49SBLBG
49SBLBH
49SBLBE
49SPL0BRJ
49SPL0BRF
49SPL0BRG
49SPL0BRH
49SPL0BRE
49SPL0AGJ
49SPL0AGF
49SPL0AGG
49SPL0AGH
49SPL0AGE
49SPL0BRJ
49SPL0BRF
49SPL0BRG
49SPL0BRH
49SPL0BRE
49SPL0AGJ
49SPL0AGF
49SPL0AGG
49SPL0AGH
49SPL0AGE
Red, Green, Amber
—
—
49SBLBL
14, 40, 22 , 43 ,
30 (2S2W) ,
LEN, CLM
1
5–8 or (300–400A)
12, 4/4X
0–8 or (20–400A)
49SBLBF
1
0–4
30 (2S1W)
1
2–4
12, 4/4X
0–4
49SPL0BRF
17, 18, 25, 26 , 32 ,
36, 37, 81, 83, 84, 87, 88,
LED, LEF, LEB,
CMN, CMF, CMB
49SBLBL
”Off”
1, 12, 4/4X
Lens Kit ONLY
(30 (2S1W))
1
(14, 40, 22, 43, 30 (2S2W),
LEN, CLM)
PL requires: (1) N.C. aux contact, 49AB01 on
sizes 00-4.
Class 22, 25, 26, 30, 32, 43, 83 & 84 requires qty. of (2)
pilot light kits. Does not apply to 49SB kits. Select
8/84
0–6 (20–400A)
0–1 3⁄4
00–4 or (20–200A)
appropriate legend plate as a separate item per type
of starter; either “FORWARD” & “REVERSE” or
“LOW” & “HIGH”.
2S2W is starter size 0–4.
Product Category: NEMA
List
Price $
Includes
The “OL
NC aux contact for NEMA starter Size 0–4.
TRIPPED” pilot light with a bimetal OLR,
requires the OLR to have a N.O. contact as well as a
N.C. contact.
Siemens Industry, Inc.
Industrial Controls Catalog
Field Modification Kits
NEMA, Reduced Voltage and Lighting
Selection
Starter/Contactor Auxiliary Contact Kits
Description
Class
Size
14, 17, 18, 22, 25, 26,
30, 32, 36, 37, 40, 43,
83, 84, 87, 88
00-4
14, 17, 18, 22, 25, 26,
36, 37, 40, 43, 87, 88
5, 6
14, 17, 18, 22, 25, 26
40, 43
7, 8
20-60 Amps
LEN, LED, LEF, LEB
100 Amps
200-400 Amps
20 Amps
30-200 Amps
CLM, CMN, CMF, CMB
300-400 Amps
Type
1 NO
1 NC
1 NC Early Break
1 NC Late Break
1 NC Extra Late Break
1 NO Extra Late Make
1 NO & 1 NC
2 NO
4 NO
3 NO & 1 NC
2 NO & 2 NC
2 NO
1 NO & 1 NC
2 NC
Catalog Number
49AB10
49AB01
49AB01EB
49AB01LB
49AB01XLB
49AB10XLM
49AB11
49AB20
49AB40
49AB31
49AB22
3RH1921-1EA20
3RH1921-1DA11
3RH1921-1EA02
1 NO & 1 NC (Inside L or R)
49CAL18-11
1 NO & 1 NC (Outside L or R)
49CAL18-11B
1 NO
1 NC
2 NO
1 NO & 1 NC
2 NC
1 NO
1 NC
1 NO/NC SPDT
1 NO/NC SPDT
1 NO/NC SPDT
2 NO/NC SPDT
1 NO & 1 NC
2 NC
2 NO
1 Coil Clearing NO & NC
1 NO & 1 NC
2 NC
2 NO
1 Coil Clearing NO & NC
49ACR0
49ACRC
49ACR7
49ACR6
49ACR8
49D22125001
49D22125002
49CE42SPDT
3RH1921-1DA11
CLM4097291
CLM4097292
CLMFCAK11
CLMFCAK02
CLMFCAK20
CLMFCCK11
CLMHCAK11
CLMHCAK02
CLMHCAK20
CLMHCCK11
Type
Catalog Number
2 NO/2 NC DPDT (NEMA A600)
HA261234
1 NO/1 NC 240V
1 NO/1 NC 480V
(2) 1 NO/1 NC SPDT-480V
A02ED62
A02FD64
A02JLD64
List Price $
Disconnect Auxiliary Switch Kits
Disconnect Amp or
CB Rating
Description
Class
Non-fusible
or Fusible Type
17, 25, 32, 37, 83, 84,
30 - 200A
87, 88, LED, LEF, CMN, CMF
MCP
18, 26, 32, 37, 83, 84,
87, 88, LEB, CMB
3A–125A
250A
400A-600A
List Price $
Control Power Transformer Kits
Description
Recommended Transformer Size
Control Size Transformer VA
45 or 50
75
100
150
300
00–21⁄2
3–31⁄2
4
5-6
7-8
Lighting Control
Transformer
50/60HZ
CLM
20A, 2 - 12P
30A, 3P
30A, 6 - 12P
60A, 3P
60A, 4 - 6P
60A, 8 - 12P
100/200A, 3P
100/200A, 5P
300/400A, 3P
LEN
20A, 3 - 12P
30/60A, 3 - 6P
30/60A, 9 - 12P
100/200A, 3P
300/400A, 3P
Installation of CPTs may require a
45VA transformer kits will include
150
100
200
100
150
250
200
250
250
Catalog Number
45 VA
50 VA
100 VA
150 VA
200 VA
300 VA
500 VA
KT*050
KT*050P
KT*100
KT*150
KT*200
KT*300
KT*500
List Price $
Replace * with code from Transformer table. Kits used with NEMA 1
general purpose lift-off cover type require extra wide enclosure.
Class 14 Sizes 0-21⁄2
Class 30 (2S2W) Sizes 0-21⁄2
Class 30 (2S1W) Sizes 0-13⁄4
Transformer Table
Primary Volts Secondary Volts Code
120
208
208
240/480
240/480
277
277
600
600
24
24
120
24
120
24
120
24
120
1
G
H
4
8
5
7
6
9
25
25
50
75
150
larger enclosure.
secondary but not
primary fusing. Sizes 50VA and higher include
Siemens Industry, Inc.
Industrial Controls Catalog
VA
Rating
2-pole primary fusing and 1-pole secondary fusing.
Category: MCCB.
Product
Product Category: NEMA
For
24VAC control a minimum of 100VA CPT is
required.
Assembled at the factory.
8/85
Field Modification Kits
ESP200 Accessories
Selection
Accessories
Description
Catalog Number
List Price $
49ASTC1
3UB89848
ESP200 Tamper Resistance Cover
49ASMP1
49ASMP2
ESP100/200 Mounting Plate
49ASMP3
8/86
Starter Mounting Adaptor Plate
49D70084
Mounting Kit
49ASMS1
Universal Reset Operator
8" for class 36, 37 and 81
in NEMA 1, 12 and 3/3R
49MARB
Single Reset (blue)
for class 14, 17, 18, 22, 25, 26, 30 and 32
in NEMA 1, 12 and 4/4X
49MBRS
Single Reset (red)
for class 14, 22 and 30
in NEMA 4/4X
49MBRSR
ESP200 Reset Extender
49ASRE
Oil Tight Boot
For Single and Multi Unit using 49MARSR Resets
Enclosure type 4, 4X
52AABA
Current Transformer 300:5 use with 48ATJ3S00
97CT005
Current Transformer 400:5 use with 48ATK3S00
97CT006
Current Transformer 600:5 use with 48ATL3S00
97CT008
Current Transformer 750:5 use with 48ATM3S00
97CT009
Current Transformer 1200:5 use with 48ATN3S00
97CT012
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Field Modification Kits
NEMA Accessories
Selection
Miscellaneous Kits
Description
Enclosure
Type
Class
Mechanical Interlock
for Horizontally
Mounted Contactors
Open
Mechanical Interlock
14, 40
Open
Includes wire &
mounting plate
14, 40
Open
14, 40
Open
All but
Class LE, CLM
All
00–4
All but
Class LE, CLM
All
00–13⁄4
LEN, LED, LEF, LEB
All
20 Amps
CLM
All
20 Amps
LEN, CLM
Open
30, 60 Amp
49MCMPMA
All but
Class LE, CLM
All
00–13⁄4
49SAE
14, 40
All
2-21⁄2
3-31⁄2
4 Line 4 Load
49SAAF
49SAAH
75D35994002
14, 40
All
5, 6
3RT1966-4G
14, 40
All
7
8
49ZATK750-3
49ZATK1650-6
All
All
All
49D11960001
All
All
All
49D45584002
Includes
mounting plate
(Different Frame Sizes)
Surge Suppressor for 120V AC
coil. Limits transient voltage
produced by the coil to 220%
maximum peak line volts.
NO 36A at 600V AC Max
NC 25A at 600V AC Max
2 NC (mounts to contactor or power pole)
2 NO (mounts to contactor or power pole)
2 NO (mounts to contactor only)
1 NO (mounts to contactor only)
Top or Bottom, 2-Pole
Main Contacts
Top, 3-Pole
Lighting Contactors
Top or Bottom, 4-Pole
Top or Bottom, 6-Pole
Auxiliary
Power Pole
Lug Kit for Contactors
Item
49SAAF
49SAAH
75D35994001
Mounting Kit for Open
Heating & Lighting
6 - 12-poles
Includes 3 power lugs
for making extra
connections to the load
side of the contactor
For AL/CU Wire
Wire Range
2-14
For AL/CU Wire
2/0-14
250MCM-6 Use CU Only
Ground Lug Kit
Meets CSA Standard
22.2 No 14-1973
1 Conductor 2-14
For AL/CU Wire
Lightning Arrestor
Illustration
49CCF22H
49EEF22H
49GGF22H
49HHP22H
49JJG22H
3RT1954-2A
3RA1963-2A
3RA1973-2A
3RA1962-2A
3RA1972-2A
49VM750H
49VM1650H
49CCF22HP
49EEF22HP
49GGF22HP
49HHP22HP
49JJG22HP
14, 40
Base Plate Only
Load Side
Power Take
Off Kit
Catalog Number List Price $
Open
Interlock Only
Auxiliary
Power Pole
00–1
1 3⁄4
2, 2 1⁄2
3, 3 1⁄2
4
5, 6
5
6
5
6
7
8
00–1
1 3⁄4
2, 2 1⁄2
3, 3 1⁄2
4
Left
2, 2 1⁄2
3, 3 1⁄2
14, 40
Includes wire
Wire Kit Only
Surge
Suppressor
Controller
Size
Right
3, 3 1⁄2
2, 2 1⁄2
49L107944
49L107945
49D26344
49SAF0
49SAFC
49LN02A
49LN20A
49LS20A
49LS10A
CLM4097331
CLM4097332
CLM4097333
CLM4097334
Backspin Timer
On delay timer that reduces
risk of starting into a
backspin
87, 88
All
All
3RP2025-1AQ30
3RP2025-1AP30
Hole Plug
Covers the hole that is
typically used for the
conduit hub
87
All
1-4
49D41149006
Description
Contactor
Wire Size
Catalog Number
Lug Kit
1 Kit = 1 Terminal block. 1 kit
necessary for each line and load.
NEMA size 4 (Vacuum)
NEMA size 5
NEMA size 6
2/0 to 600 MCM, max. one 500MCM
& one 600MCM
3RT1966-4G
List Price $
3RT1966-4G
Surge
Suppression for NEMA sizes 5 – 8 are supplied
internal with the coil. For size 4 panel mount.
Siemens Industry, Inc.
Industrial Controls Catalog
Only
3 lugs are suplied for line or load.
If lugs for line and load are required order 2 kits.
Product Category: NEMA
Lug
Kit for contactors include 3 lugs for line or load.
75D35994001 for line side.
75D35994002 for load side.
8/87
Field Modification Kits
NEMA Accessories
Selection
Fused and Non-Fused Disconnect Switch Kits (Includes load base plus line and load fuse clips)
Basic
Switch
Ampere
Rating
Switch
Catalog
Number
Non-Fused
List
Price $
Switch
Catalog
Number
Fused
30
HNB612
60
HNB623
100
HNB623
HFB21
HFB612
HFB22
HFB62
HFB63
200
HNB64
HFB64
List
Price $
Kit
Description
Load Base
Catalog
Number
Class J
30A, 250V
30A, 600V
60A, 250V
60A, 600V
100A, 250V
100A, 600V
200A, 250V
200A, 600V
—
HBB612
—
HBB62
—
HBB63
—
HBB64
List
Price $
—
Load Base
Catalog
Number
Class H
List
Price $
Lug
Wire
Size
#14-2 AWG (Cu/AI)
—
HBB21
HBB612
HBB22
HBB62
HBB63
—
HBB64
#6-300 AWG (Cu/AI)
—
#14-2 AWG (Cu/AI)
#14-1/0 AWG (Cu/AI)
Class R Fuse Conversion Kits
Catalog Number
Description
HR21
HR612
HR612
HR62
HR63
HR64
30A, 240V
30A, 600V
60A, 240V
60A, 600V
100A, 240/600V
200A, 240/600V
List Price $
Hazardous Location Accessories For Enclosure Types 7 & 9
Description
Conduit Size Inches
Install in bottom as drain.
Install in top as breather.
Suitable for Class I groups C & D and
for Class II groups F & G applications only.
for 1⁄2" NPT.
Breather/Drain
51AADB
⁄2
⁄4
1
11⁄2
2
21⁄2
51AAHA
51AAHB
51AAHC
51AAHD
51AAHE
51AAHF
3
⁄4–1⁄2
1–1⁄2
11⁄2–3⁄4
11⁄2–1
51AARBA
51AARCA
51AARDB
51AARDC
2 1⁄2–3⁄4
2 1⁄2–1
2 1⁄2–11⁄2
2 1⁄2–2
51AARFB
51AARFC
51AARFD
51AARFE
3–1
3–11⁄2
3–2
3–21⁄2
51AARGC
51AARGD
51AARGE
51AARGF
1
3
For tapered NPT conduit openings.
Hole Plugs
Cast aluminum, UL Recognized and
CSA Certified. Used to reduce existing
tapered NPT conduit opening when
required.
Reducer Bushings
Catalog Number List Price $
Conduit Hubs
Conduit
Size
Description
Conduit Hubs For Enclosures
Noncombination - NEMA 12
may be field modified for NEMA 3/3R.
Combination - NEMA 12 may be field
modified for NEMA 3/3R/4 enclosure.
Use UL Listed conduit hub for
the appropriate NEMA type.
NEMA 3R requires the location of the conduit
hub to be at a level above the lowest live part
and holes of 1/8" dia. to be added in the
bottom of the enclosure.
Does not apply to class 87 Pump Panels.
Product
Product
8/88
Category: PILO.
Category: HDSS.
Metal Hub
Metal Hub
3
⁄4"
1"
1 1⁄2"
2"
2 1⁄2"
1"
1 1⁄2"
2"
2 1⁄2"
Class
Controller
Size
Enclosure
Type
Catalog
Number
49MACML
49MACMD
49MACMN
49MACMF
49MACMG
All
All
12, 3, 3R, 4
81, 87
All
3R
List
Price $
75D41149001
75D41149003
75D41149004
75D41149005
For
Class R fuses order Class H kit from this table and
the Class R conversion kit.
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Field Modification Kits
NEMA, Overload Relays
Selection
Sirius 3RB20
Illustration
Description
For Overload Type
Catalog Number
3RB206
3RU1900-1A
List Price $
Reset mechanisms
Reset plunger
Mounts directly to overload relay. Requires
separate reset operator in enclosure door. Kit
includes reset plunger, holder and funnel.
Reset plunger with reset button
Flexible cable reset mechanism
Requires a 6.5 mm hole in the
enclosure with a maximum
enclosure thickness of 8 mm.
Flexible reset
Cable length
15.75 in (400mm)
3RU1900-1B
3RB206
Cable length
23.62 in (600mm)
3RU1900-1C
Covers
Tamper resistant cover for current setting and manual/automatic reset button.
3RB206
3RB2984-0
Competitive Retrofit Overload Plates
Manufacturer
NEMA
Size
Plate
Part Number
A-B
A-B
Sq. D
0, 1
2
0, 1
49D57090
49D57161
49D57091
List Price $
Electronic Coil System with Remaining Lifetime Indication and 24VDC PLC Output
Class
Size
5
All
6
Model Type
21 - 27V
Catalog Number
P
V
P
V
–
–
–
–
Siemens Industry, Inc.
Industrial Controls Catalog
List Price $
–
–
–
–
96 - 127V
Catalog Number
3RT1965-5PF31
3RT1966-5PF31
3RT1975-5PF31
3RT1976-5PF31
Product Category: NEMA
List Price $
200 - 277V
Catalog Number
List Price $
3RT1965-5PP31
3RT1966-5PP31
3RT1975-5PP31
3RT1976-5PP31
8/89
Field Modification Kits
Class MT, MTG
Selection
Fuse Blocks, Touch-Safe Terminal Covers
Catalog Number
Description
International Fusing
List Price $
Catalog Number
Description
List Price $
1-Pole Fuse Block,
Touch-Safe. Up to 6.3A
for 5 mm ҂ 20 mm or
5 mm ҂ 25 mm (Requires
DIN Rail Mounting)
2-Pole Primary Class CC
Fuse Block for domestic
fusing. Max 600V.(Single- ole cover kits,
if required are listed
below. One cover kit
required per pole.)
8WA1011-1SF12
KCCFP2RG
1-Pole Fuse Block,
Touch-Safe 25A, for
10 ҂ 38 mm Cylindrical
Fuses. (Requires DIN
Rail Mounting.)
1-Pole Secondary
Midget Fuse Block for
13/32 ҂ 11⁄2 domestic
Fusing. Max 250V.
(Single pole cover kits,
if required are listed
below.)
3NW7011
2-Pole Fuse Block,
Touch-Safe 25A, for
10 ҂ 38 mm Cylindrical
Fuses. (Requires DIN
Rail Mounting.)
KCCF1G
3NW7021
Single Pole Fuse Block
cover Kit for domestic
fuse blocks listed above.
(For primary or secondary)
2-Kits required for 2-pole
fuse block.
1-Pole Fuse Block,
Touch-Safe 4-50A, for
14 ҂ 51 mm Cylindrical
Fuses. (Requires DIN
Rail Mounting.)
KCCFBCK
3NW7111
Snap-On Transformer
Terminal Touch-Safe Cover
Kit. (Includes primary and
secondary covers.)
KTTSC6P (cover for 6
terminals) also available.
Fuse Block DIN Rail
Mounting for separate
screw mounting to panel.
(Max 2-pole 2-25A size
per rail.)
(Max 1-pole 4-50A size
per rail.)
KTTSC4P
(cover for 4 terminals)
Product
8/90
49FCCPT
Fuse Clips 2 per pack
49JUCPT
Terminals Jumper
8WA1815
Category: IEC.
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Heavy Duty Control
Non-Combination Enclosure Kits, Class 49
Selection
49
Class
49 — Field
Kit
E
B
14
E
B
11
07
05
Reset Installation
Starter Size
E — 00, 0, 1, 13⁄4
G — 2, 21⁄2
I — 3, 31⁄2
J—4
Type
E — Enclosure
Only Model
B — Model
C — 2002
Depth
(In Inches)
R — Reset
Width
(In Inches)
NEMA Type
B — NEMA 1
0 — NEMA 12
W — NEMA 4 S.S.
Product Class
14 — Class 14, 40
22 — Class 22, 43
30 — Class 30
R
Height
(In Inches)
Non-Reversing Starters & Contactors Class 14, 40
General Purpose (Clamshell)
NEMA 4/4X Stainless
Watertight, Dust-tight, Corrosion Resistant
NEMA 12/3/3R
Without CPT
With CPT (Extra Wide)
Without CPT
With CPT (Extra Wide)
Without CPT
Model C Enclosure
Model C Enclosure
Model B Enclosure
Model B Enclosure
NEMA 1
Size
Catalog Number
00–13⁄4
2, 21⁄2
3, 31⁄2
3, 31⁄2
4
49EC14EB110705R
49EC14GB140807R
49EC14IB201208R
—
49EC14JB251409R
List
Price $ Catalog Number
—
49EC14IB201208R
49EC14IB201208R
49EC14IB201208R
49EC14JB251409R
49EC14JB251409R
Model B Enclosure
Max
CPT List
VA Price $ Catalog Number
200
200
100
250
300
List
Price $
49EB14EW130806R
49EB14GW160907R
49EB14JW261408R
—
—
49EB14JW261408R
Catalog Number
Industrial Use, Weatherproof
Max
CPT List
VA
Price $
49EB22EW131306R
49EB22GW161406R
49EB14JW261408R
—
49EB22JW302410R
—
Catalog Number
With CPT (Extra Wide)
Model B Enclosure
List
Price $ Catalog Number
49EB14E0130806R
49EB14G0160907R
49EB14J0261408R
—
—
49EB14J0261408R
Max
CPT List
VA
Price $
49EB22E0131306R
49EB22G0161406R
49EB14J0261408R
—
49EB22J0302410R
—
Reversing Starters & Reversing Contactors Class 22, 43
General Purpose (Clamshell)
NEMA 4/4X Stainless
Watertight, Dust-tight, Corrosion Resistant
NEMA 12/3/3R
Without CPT
With CPT (Extra Wide)
Without CPT
With CPT (Extra Wide)
Without CPT
Model C Enclosure
Model C Enclosure
Model B Enclosure
Model B Enclosure
NEMA 1
Size
Catalog Number
00–13⁄4
2, 21⁄2
3, 31⁄2
4
49EC14IB201208R
49EC14IB201208R
49EC14JB251409R
49EC14JB251409R
List
Price $ Catalog Number
49EC14IB201208R
49EC14IB201208R
49EC14JB251409R
49EC14JB251409R
Model B Enclosure
Max
CPT List
VA Price $ Catalog Number
200
200
250
300
List
Price $
49EB22EW131306R
49EB22GW161406R
49EB22IW261808R
49EB22JW302410R
Catalog Number
Industrial Use, Weatherproof
Max
CPT List
VA
Price $
49EB22EW131306R
49EB22GW161406R
49EB22JW302410R
49EB22JW302410R
Catalog Number
49EB22E0131306R
49EB22G0161406R
49EB22I0261808R
49EB22J0302410R
With CPT (Extra Wide)
Model B Enclosure
List
Price $ Catalog Number
Max
CPT List
VA
Price $
49EB22E0131306R
49EB22G0161406R
49EB22J0302410R
49EB22J0302410R
Two-Speed Two-Winding Starters Class 30
NEMA 1
Without CPT
With CPT (Extra Wide)
Model C Enclosure
Model C Enclosure
Size
Catalog Number
0–13⁄4
2, 21⁄2
3, 31⁄2
4
49EC14IB201208R
49EC14IB201208R
49EC14JB251409R
49EC14JB251409R
List
Price $ Catalog Number
49EC14JB251409R
49EC14JB251409R
49EB22JB302410R
49EB22JB302410R
NEMA 4/4X Stainless
Watertight, Dust-tight, Corrosion Resistant
NEMA 12/3/3R
Without CPT
With CPT (Extra Wide)
Without CPT
Model B Enclosure
Model B Enclosure
Model B Enclosure
Max
CPT List
VA Price $ Catalog Number
200
200
300
300
List
Price $
49EB30EW131306R
49EB30GW161406R
49EB30IW261808R
49EB22JW302410R
Catalog Number
Industrial Use, Weatherproof
Max
CPT List
VA
Price $
49EB30GW161808R
49EB30GW161808R
49EB22JW302410R
49EB22JW302410R
Catalog Number
49EB30E0131306R
49EB30G0161406R
49EB30I0261808R
49EB22J0302410R
With CPT (Extra Wide)
Model B Enclosure
List
Price $ Catalog Number
Max
CPT List
VA
Price $
49EB30G0161808R
49EB30G0161808R
49EB22J0302410R
49EB22J0302410R
Two-Speed One-Winding Starters Class 30
General Purpose (Clamshell)
NEMA 4/4X Stainless
Watertight, Dust-tight, Corrosion Resistant
NEMA 12/3/3R
Without CPT
With CPT (Extra Wide)
Without CPT
With CPT (Extra Wide)
Without CPT
Model C Enclosure
Model C Enclosure
Model B Enclosure
Model B Enclosure
NEMA 1
Size
Catalog Number
0–13⁄4
2, 21⁄2
3, 31⁄2
4
49EC14IB201208R
49EB30GB161808R
49EB30IB192208R
49EB22JB302410R
List
Price $ Catalog Number
49EC14JB251409R
49EB22JB302410R
49EB22JB302410R
49EB22JB302410R
Model B Enclosure
Max
CPT List
VA Price $ Catalog Number
200
300
300
300
Note: Dimensions...See appropriate Product Class
Outline Drawing beginning on page 8/116.
For
conduit hubs and conversion instructions,
see page 8/88.
Clamshell enclosure suitable for one operating device
and two pilot lights. See Field Mods page 8/82.
Siemens Industry, Inc.
Industrial Controls Catalog
49EB30EW131306R
49EB30GW161808R
49EB22JW302410R
49EB22JW302410R
List
Price $
Catalog Number
Industrial Use, Weatherproof
Max
CPT List
VA
Price $
49EB30GW161808R
49EB22IW261808R
49EB22JW302410R
49EB22JW302410R
Hinged
cover enclosure suitable for one or more class
52 operating devices and one or more class 52 pilot
lights. See Field Mods page 8/82.
Install NEMA 1 hole plug cat. no. 3SB1902-0AR
(included) when the cover OL reset is not needed.
Install NEMA 12 hole plug cat. no. 52ABH6 (not
included) when the cover OL reset is not needed.
Product Category: NEMA
Catalog Number
49EB30E0131306R
49EB30G0161808R
49EB22J0302410R
49EB22J0302410R
With CPT (Extra Wide)
Model B Enclosure
List
Price $ Catalog Number
Max
CPT List
VA
Price $
49EB30G0161808R
49EB22I0261808R
49EB22J0302410R
49EB22J0302410R
Install
NEMA 4X stainless steel hole plug cat. no.
52ABHS (not included) when the cover OL reset is not
needed.
8/91
Heavy Duty Control
Lighting Enclosure Tables
Selection
Lighting & Heating Contactors Class LE
NEMA 4/4X Stainless
NEMA 1
General Purpose (Clamshell)
2-12
3
6-9
12
3
6-9
12
3
Industrial Use
Without CPT
With CPT (Extra Wide)
Without CPT
With CPT (Extra Wide)
Without CPT
With CPT (Extra Wide)
Model C Enclosure
Model C Enclosure
Model B Enclosure
Model B Enclosure
Model B Enclosure
Model B Enclosure
Size Pole Catalog Number
20A
30A
30A
30A
60A
60A
60A
100A
NEMA 12/3/3R
Watertight, Corrosion Resistant
49EC14EB110705R
49EC14EB110705R
49EC14IB201208R
49EC14IB201208R
49EC14EB110705R
49EC14IB201208R
49EC14IB201208R
49EC14IB201208R
List
Price $ Catalog Number
49EC14IB201208R
49EC14IB201208R
49EC14IB201208R
49EC14JB251409R
49EC14IB201208R
49EC14IB201208R
49EC14JB251409R
49EC14IB201208R
Max
CPT
List
Price $ Catalog Number
200VA
200VA
200VA
250VA
200VA
200VA
250VA
200VA
List
Price $
49EB22GW161406R
49EB22GW161406R
49EB14JW261408R
49EB14JW261408R
49EB22GW161406R
49EB14JW261408R
49EB14JW261408R
49EB14JW261408R
Catalog Number
Max List
CPT Price $
Catalog Number
49EB22GW161406R
49EB22GW161406R
49EB14JW261408R
—
49EB22GW161406R
49EB14JW261408R
—
49EB14JW261408R
—
—
—
—
—
—
—
—
49EB22G0161406R
49EB22G0161406R
49EB14J0261408R
49EB14J0261408R
49EB22G0161406R
49EB14J0261408R
49EB14J0261408R
49EB14J0261408R
—
—
List
Price $
Catalog Number
49EB22G0161406R
49EB22G0161406R
49EB14J0261408R
—
49EB22G0161406R
49EB14J0261408R
—
49EB14J0261408R
Max List
CPT Price $
—
—
—
—
—
—
—
—
—
—
Lighting & Heating Contactors Class CLM
General Purpose (Clamshell)
NEMA 4/4X Stainless
Watertight, Corrosion Resistant
NEMA 12/3/3R
Without CPT
Without CPT
With CPT (Extra Wide)
Without CPT
Model B Enclosure
Model B Enclosure
NEMA 1
Model C/B Enclosure
Size Pole Catalog Number
20A
30A
30A
60A
60A
100A
2-12
2-5
6-12
2-5
6-12
2-5
49EC14GB140807R
49EC14EB110705R
49EB30GB161808R
49EC14GB140807R
49EB30IB192208R
49EC14IB201208R
With CPT (Extra Wide)
Model C/B Enclosure
List
Price $ Catalog Number
49EC14IB201208R
49EC14IB201208R
49EB30GB161808R
49EC14IB201208R
49EB30IB192208R
49EC14IB201208R
Model B Enclosure
Max
CPT
200VA
200VA
200VA
200VA
250VA
200VA
Note: Dimensions...See appropriate Product Class
Outline Drawing on page 8/129.
For
conduit hubs and conversion instructions,
see page 8/88.
enclosure suitable for one operating device
and two pilot lights. See Field Mods page 8/82.
Clamshell
8/92
List
Price $ Catalog Number
49EB22GW161406R
49EB22GW161406R
49EB30GW161808R
—
—
—
List
Price $
—
—
—
Industrial Use
Catalog Number
Max List
CPT Price $
Catalog Number
49EB22GW161406R
49EB22GW161406R
49EB30GW161808R
—
—
—
—
—
—
—
—
—
49EB22G0161406R
49EB22G0161406R
49EB30G0161808R
—
—
—
Hinged
cover enclosure suitable for one or more class
52 operating devices and one or more class 52 pilot
lights. See Field Mods page 8/82.
Install NEMA 1 hole plug cat. no. 3SB1902-0AR
(included) when the cover OL reset is not needed.
Install NEMA 12 hole plug cat. no. 52ABH6 (not
included) when the cover OL reset is not needed.
Product Category: NEMA
—
—
—
With CPT (Extra Wide)
Model B Enclosure
List
Price $
—
—
—
Catalog Number
49EB22G0161406R
49EB22G0161406R
49EB30G0161808R
—
—
—
Max List
CPT Price $
—
—
—
—
—
—
—
—
—
Install
NEMA 4X stainless steel hole plug cat. no.
52ABHS (not included) when the cover OL reset is not
needed.
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Starter Enclosure Kits
Features and Benefits
Features
▪ Manufactured with a cold forming “TOX” process
▪ 100kA short circuit rating when protected with class R fuses
to 600V or MCP to 480V and when installing listed components
from the instruction guide
▪ Enclosure types available, Nema 1, 12, 3/3R and painted NEMA 4.
Nema 12 field convertible to 3/3R/4 with the appropriate conduit
hub and drain hole
▪ Pre-Drilled mounting panels
▪ Heavy duty quarter turns
▪ Industrial type disconnect handle
Disconnect Type Enclosure Kit
▪ Used to assemble both non-fusible and fusible combination starters
▪ Accommodates Class 14 full voltage non-reversing (FVNR) NEMA
starters 00 – 4 including Siemens exclusive half sizes
▪ Handle mechanism, power wire, mounting panel, reset assembly,
and instruction guide included. Hardware for panel mounted
devices and disconnect switch are not included
MCP Type Enclosure Kit
▪ Used to assemble combination starters with circuit breakers
▪ Accommodates Class 14 full voltage non-reversing (FVRN) NEMA
starters 00 – 4 including Siemens exclusive half sizes
▪ Handle mechanism, power wire, mounting panel, reset assembly
and instruction guide included. Circuit breaker not included however,
mounting hardware for the circuit breaker is
How to Select the Required Kits to Assemble a Combination Starter
1. From the catalog, select a class 14 open type starter with the required
starter size and overload relay type.
2. Based on the starter size, select the enclosure kit from table 1a for
fusible or non-fusible combination starters or select from table 1b
for combination starters with an MCP.
3. For a non-fusible combination starter, select the disconnect switch kit from table 2a.
For a fusible combination starter, select the appropriate disconnect switch, fuse clip
kit, and class R rejection kit from table 2b (for H fusing, class R rejection kit not required).
For combination starters with MCP, select the appropriate circuit breaker kit from table 3.
Nomenclature for Combination Enclosure Kits
49
E
C
17
B
B
24
11
08
R
Class
49 — Field Kit
Reset Installation
R — Reset Installed
Type
E — Enclosure Kit
Model
C — Model C
Product Class
17 — Disconnect Type
18 — Circuit Breaker Type
Depth
(In Inches)
Width
(In Inches)
Height
(In Inches)
Enclosure Type
B — NEMA 1
N — NEMA 12/3R, 4 Painted
Disc / CB Amp Rating
B — 30/60 amp disconnect
C — 100 amp disconnect
D— 125 amp breaker frame
E — 150 amp breaker frame
F — 200 amp disconnect
Siemens Industry, Inc.
Industrial Controls Catalog
8/93
Combination Starter Enclosure Kits
Selection
Table 1a - FVNR Combination Starter Kits for use with Disconnect Devices
Starter
Size
0-2
2 1⁄2 - 3
3 1⁄2 - 4
Disc.
Amp
Rating
NEMA 1
Nema 12, 3/3R, 4 Painted 햲
General Purpose
Industrial Use, Weatherproof, Watertight, Dust-tight
Catalog Number
60
100
200
List Price $
Catalog Number
49EC17BB241108R
49EC17CB242008R
49EC17FB362408R
List Price $
49EC17BN241108R
49EC17CN242008R
49EC17FN362408R
Table 1b. – FVNR Combination Starter Kits for use with MCP Devices
Starter
Size
Max
MCP
Amps
0-2
2 1⁄2 - 3
3 1⁄2
4
50
100
125
150
Nema 12, 3/3R, 4 Painted 햲
NEMA 1
General Purpose
Industrial Use, Weatherproof, Watertight, Dust-tight
Catalog Number
List Price $
Catalog Number
49EC18DB241108R
49EC18DB242008R
49EC18DB362408R
49EC18EB362408R
List Price $
49EC18DN241108R
49EC18DN242008R
49EC18DN362408R
49EC18EN362408R
Table 2a – Non-Fusible Disconnect Kits
Disconnect Switch
Switch Rating
30A
60A
100A
200A
Catalog Number
List Price $
HNB612
HNB623
HNB623
HNB64
Table 2b – Fusible Disconnect Kits
Disconnect Switch
Fuse Clip Ratings
Class
Catalog Number
30A-250V
30A-600V
60A-250V
60A-600V
100A-250V
100A-600V
200A-250V
200A-600V
H
H
H
H
H
H
H
H
HFB21
HFB612
HFB22
HFB62
HFB63
HFB63
HFB64
HFB64
Fuse Clip Kit
List Price $
Rejection Clips for Class R Fusing
Catalog Number
List Price $
HBB21
HBB612
HBB22
HBB62
HBB63
HBB63
HBB64
HBB64
Catalog Number
List Price $
HR21
HR612
HR612
HR62
HR63
HR63
HR64
HR64
Table 3 – Circuit Breaker Kits
MCP Type Used with Solid State
Overload Relay
Starter
Size
0
1
1 3⁄4
2
2 1⁄2
3
3 1⁄2
4
햲
MCP Type Used with
Thermal Overload Relay
Overload
Amp
Range
Motor Circuit
Interrupter
Amps
Circuit
Breaker Kit
Motor Circuit
Interrupter
Amps
Circuit
Breaker Kit
0.75-3.4
3-12
5.5-22
3
10
25
ED63A003
ED63A010
ED63A025
3
10
25
ED63A003
ED63A010
ED63A025
0.75-3.4
3-12
5.5-22
10-40
10-40
13-52
25-100
25-100
50-200
50-200
3
10
25
30
40
50
100
100
125
150
ED63A003
ED63A010
ED63A025
ED63A030
ED63A040
ED63A050
ED63A100
ED63A100
ED63A125
FXD63A150L
3
10
25
30
40
50
100
100
125
150
ED63A003
ED63A010
ED63A025
ED63A030
ED63A040
ED63A050
ED63A100
ED63A100
ED63A125
FXD63A150L
For conduit hubs and conversion instructions,
see page 8/88.
8/94
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Factory Modifications
Selection
Ordering Information
䊳
All modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction
may not apply when certain modifications and special features are added.
Pilot Devices
Description
Modification
Class
Enclosure
Type
14, 17, 18, 36, 37, 40, 83, 84, CLM, CM, LE
22, 25, 26, 43
30, 32
14햲 , 17, 18, 22햲 , 25, 26, 30햲 , 32, 36, 37, 40햲 , 43햲
83, 84
14, 17, 18, 36, 37, 40, 83, 84, LE
CM, CLM
All
All햲
All
All햲
All
All
All
A1
Push Buttons
Start, Stop
Forward, Reverse, Stop
High, Low , Stop
E-Stop
Test Push Buttons
For 24 volt HOA control,
20 Amp contactor only
CM, CLM
1
EM
Off-On
14, 17,18, 22, 25, 26, 30, 32, 36, 37, 40, 43,
83, 84, CLM, CM, LE
All
A4
Auto-Off
Forward-Off-Reverse
High-Off-Low
Hand-Off-Auto (Keyed)
Auto-Off-Low-High
14, 17, 18, 40, 83, 84, CM, CLM, LE
22, 25, 26, 43
30, 32
14, 17, 18, 36, 37, 40, 83, 84, LE, CLM, CM
30, 32
All햲
All
All
All 햲
All햲
A6
Hand-Off-Auto
Selector Switches
Suffix
List Price $
A2
ES
K1
A3
A3
A5
A9
A0
Pilot Lights
Class
Enclosure Type
Lens
Color ➔
Red
Legend➔
Suffix ➔
Green
White
Red
Push-To-Test
Green
Push To-Test
OL
Tripped
Control
Power
On
On
For/Rev
Low/High
On
For/Rev
Low/High
Off
FL햴
FW 햲
FS햲
FT 햲
FU햲
Green Red
Green Amber
On
On
For/Rev
For/Rev
Low/High Low/High Run
Run
Off
Off
FA
FD
FJ
FK
FB
Red
FC
Green
Push To-Test
14, 40, 17, 18, 36, 37, 81, 87,
88, LE, CLM, CM
All
22, 25, 26, 30, 32, 43, 83, 84 All
Coil Options
Class 14, 17, 18, 22, 25, 26, 30, 32, 40, 43, 83햵 , 84햵 , 87, 88
Volts 60 HZ
Volts 50 HZ
Coil Letter
Change
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
24
110
110/190–220
—
190–220
240
190–220/380–440
380–440
550
J
F
A
D
G
L
C
H
E
DC Coil 햳
24V
48V
125V
250V
S햶
U
V
W
햲
Controller Size — List Price $
AC (50–60 HZ) or DC
Coil Letter
Change
00–21⁄2
3, 31⁄2
4
NC
NC
NC
23–26V
42–48V
110–127V
200–220V
220–240V
240–277V
380–420V
440–480V
575–600V
J
U
F
D
G
L
K
H
E
Not Available on Class 14, 40, 22, 43, 30 (size 00–4) and
Class LE, CLM (20–30amp) NEMA 1 clamshell enclosures.
Siemens Industry, Inc.
Industrial Controls Catalog
Controller Size 4 (Vacuum Only)
Size 5 & 6 (ALL)
NC
Miscellenious Options
Omit Alternator
(deduct)
Duplex with Separate
Relay Alternation
Duplex with lead pump
transfer switch
햳
햴
DC coils include 1 NC, late break aux. contact. This aux.
contact takes up one side of the starter (00–4 only).
Available with solid-state OLR starter sizes 00–8 and
with bimetal OLR starter sizes 00–21⁄2.
Product Category: NEMA
햵
햶
Class
Change the
92 to
List
Price $
83, 84
95
83, 84
93
NC
83, 84
94
NC
For Class 83, 84 standard enclosure (92) alternating
relay available in 24V or 120V control only.
S coil is not available for size 4 contactors or starters.
8/95
Factory Modifications
Selection
Ordering Information
䊳
䊳
Transformer Table
Primary
Volts
120
208
208
240
240
277
277
380
415
480
480/240
480/240
600
600
Replace (*) with letter from Transformer Table.
Prices for modifications are additions to standard equipment prices and are not to be used as separate
selling prices. All modifications will consist of Siemens standard components as available. Standard
equipment dimensions and enclosure construction may not apply when certain modifications and special
features are added.
Secondary
Volts
24
24
120
24
120
24
120
110
100
240
24
120
24
120
Letter
B
S
T
J
F
N
P
U
W
R
D
A
E
C
Control Power Transformers
Description
Standard Capacity
with 1-Secondary Fuse
Standard Capacity
with 2-Primary and
1-Secondary Fuse
100VA Extra Capacity
with 2-Primary and
1-Secondary Fuse
150VA Extra Capacity
with 2-Primary and
1-Secondary Fuse
Catalog
No Suffix
B*
D*
C*
C*1
Product
Class
Enclosure 20–60
Type
00–2 1⁄2
14, 17, 18, 22, 25, 26, 30,
32, 40, 43, 81, 83 , 84 , 87
14, 17, 18, 22, 25, 26, 30,
32, 40, 43, 81, 83 , 84 , 87,
LE, CLM, CM
14, 17, 18, 22, 25, 26, 30, 32, 40,
43, 81, 83 , 84 , 87, LE, CLM, CM
36, 37, 88
14, 17, 18, 22, 25, 26, 30, 32, 40,
43, 81, 83 , 84 , 87, LE, CLM, CM
36, 37, 88
1, 3, 4, 12
7&9
100
—
200
300–400
—
—
3
31⁄2, 4
5
6
7
8
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Lighting & Heating Ratings (Amps)
Motor Controller Size
1, 3, 4, 12
7&9
1, 3, 4, 12
7&9
All
1, 3, 4, 12
All
Factory Assembled Fuse Clips—Class 25, 32, 84
Fuse
Clip Amps
30
30
60
60
100
100
200
200
400
400
600
600
800
1600
Volts
250
600
250
600
250
600
250
600
250
600
250
600
600
600
Rejection
Clip Suffix
Note: Factory will furnish the same voltage coils as
transformer secondary voltage (except with class
36,37).
The standard control transformer supplied for starter
sizes 00 through 21⁄2 with control voltage other than
24VAC will be rated 45VA and have the appropriate
secondary fuse. Primary fuses will not be supplied as
8/96
List Price $
10
11
12
13
14
15
16
17
18
19
20
21
23
25
standard. For primary fuse option select
appropriate suffix from table.
ESP200 styles add the rejection clip suffix to the
end of the base style catalog number. For thermal
styles add the rejection clip suffix immediately before
the 81 in the part number.
For
Product Category: NEMA
For
24VAC control a minimum of 100VA CPT is
required.
84 Duplex Controllers require two fusible
disconnects thus multiply the price adder by two.
Price x 2 Class 83 and 84.
Class
Siemens Industry, Inc.
Industrial Controls Catalog
Factory Modifications
Selection
Ordering Information
䊳
Prices for modifications additions to standard equipment prices and are not to be used as separate selling prices. All modifications will
consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction may not apply when
certain modifications and special features are added.
Additional Auxiliary Contacts
Class
햴
14, 17, 18, 40, 83 , 84
햴
22, 25, 26, 43 &
30, 32 (2-winding)
30, 32
(1-winding)
LE, CLM, CM
CLM, CM
Controller Size — List Price $
NO
Contacts
NC
Contacts
Catalog Number
Suffix
5–6
7–8
—
—
1
2
G01
G02
—
—
—
1
1
1
—
1
2
G10
G11
G12
—
—
—
—
2
2
2
2
—
1
2
3
G20
G21
G22
G23
3
3
3
1
2
3
G31
G32
G33
4
4
4
4
—
1
2
4
G40
G41
G42
G44
5
5
5
—
1
3
6
6
00–13⁄4
2–4
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
G50
G51
G53
—
—
—
—
—
—
—
—
—
2
G60
G62
—
—
—
—
—
—
7
1
G71
—
—
—
8
—
—
2
G80
G02햲
—
—
—
—
—
2
2
4
4
6
8
0
2
2
4
4
6
8
1
0
2
2
—
2
0
4
2
0
2
—
2
—
4
2
—
1
2
0
2
G20햲
G22햲
G40햲
G44햲
G62햲
G80햲
G02햲
G20햲
G22햲
G40햲
G44햲
G62햲
G80햲
G11
G02햲
G20햲
G22햲
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Overload Options
Class 14, 17, 18, 22, 25, 26, 30, 32, 36, 37
Description
Ambient
Compensated
Bimetal
ESP200
3RB200 (Sz 5-6)
Trip
Class
Phase
Contacts
Catalog Number
Suffix
Class 10 or 20
(K or E heaters)
3-Phase or
Single Phase
NO & NC, SPDT
91
NC
81
Class 5, 10, 20,
30 selectable
Class 10
3-Phase or
Single Phase
3-Phase
NO & NC
NO & NC
Class 20
3-Phase
NO & NC
햲 Auxiliary
contacts will be added evenly across
contactors. (i.e. Class 22, G02 suffix will add 2 NC
contacts (one per contactor).
Siemens Industry, Inc.
Industrial Controls Catalog
Controller Size—List Price $
00–21⁄2
3–4
5, 6
7, 8
—
—
—
—
—
—
—
N/A
—
—
—
—
51
—
—
—
—
—
—
—
—
—
햳
햳 Double the price addition for Class 30 and 32.
햴 For class 83 and 84 contacts will be added to both
starters. Price x 2.
Product Category: NEMA
8/97
Factory Modifications
Selection
Ordering Information
䊳
Prices for modifications additions to standard equipment prices and are not to be used as separate selling prices. All
modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure
construction may not apply when certain modifications and special features are added.
Control Options
Description
Class
Enclosure
Type
Catalog Number
Suffix
Lighting Control Modules
Surge Suppression for 120V AC Coil
Disconnect Switch Interlock 2 NO/2 NC
DPDT
Motor Circuit
NO/NC
SPDT
Protector Interlock
Lightning Arrestor
Circuit Breaker Shunt Trip
Circuit Breaker Undervoltage Trip
Circuit Breaker Alarm Switch Trip
Ground Lug – 1 Conductor
Control Circuit Fuse and Holder
(Transformer Primary Fusing)
Control Circuit Circuit Breaker
Internally Operated
Space Heater (120V separate control)
Space Heater with Thermostat (120V separate control)
Surge Capacitor
Alarm Package (includes horn, light, relay & push-button)
Backspin Protection
Minimum Run Timer 0.2 sec. - 3 mins.
Blown Fuse Indicator Light
Single Phase 120VAC Combination Starter
Single Phase 240VAC Combination Starter
CLM 20 Amp
14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 83, 84, 87, 88
17, 25, 32, 37, 84, CM, LE
All
All
1, 3, 4, 4X, 12
2W, 3W, 3WS
SS
GY
18, 26, 32, 37, 84, CM, LE
All
GY
All
18, 26, 32, 37, 84, 87, 88, CM, LE
18, 26, 32, 37, 84, 87, 88, CM, LE
18, 26, 32, 37, 84, 87, 88, CM, LE
All
All
All
All
All
All
All
All
L
L6
L7
L8
L10
F1 (1 fuse)
F2 (2 fuses)
All
All
F4
All
All
87, 88
83, 84, 87, 88
87, 88
87, 88
17, 25, 32, 37, 84, 87, 88, CM, LE
17, 18
17, 18
All
All
All
All
All
All
All
All
All
SH
ST
SC
M7
T5
T6
L11
Z1
Z1
List
Price $
NC
NC
Reversing Options
Description
Reversing in one speed only 2 speed 1 winding
Reversing in one speed only 2 speed 2 winding
Reversing in both speeds 2 speed 1 winding
Reversing in both speeds 2 speed 2 winding
Reversing for Reduced Voltage
Controller Size —List Price $
Catalog Number
Suffix
Class
0
1
13⁄4
21⁄2
2
31⁄2
3
4
R6
R7
R8
R9
R
30, 32
36, 37
5
—
—
—
—
Enclosure Options Class 36, 37
Class
Enclosure
Type
Change the 8th
Character of the
Catalog Number to:
36
37
37
NEMA 12/3R
NEMA 4 (Painted)
NEMA 4 (Stainless Steel)
N
E
W
Controller Size — List Price Adder $
0–13⁄4
2, 21⁄2
3
31⁄2, 4
5
6
—
—
Enclosure Options Class 14, 17, 18
Class
14
14 (Extra Wide)
17 & 18
Enclosure
Type
NEMA 4/4X (316 Stainless Steel)
NEMA 4/4X (316 Stainless Steel)
NEMA 4/4X (316 Stainless Steel)
Change the 7th
Character of the
Catalog Number with
Bimetal OLR to:
X
X
X
Change the 8th
Character of the
Catalog Number with
ESP200 OLR to:
X
X
X
Controller Size – List Price Adder $
00–1 3/4
2–2 1/2
3
3 1/2–4
5–8
—
—
—
Note: Add price to the standard 304 stainless steel unit price.
Supplied
8/98
as NEMA 12, field convertible to NEMA 3R.
Surge
Suppression for NEMA sizes 5 – 8 are supplied
internal with the coil.
Product Category: NEMA
Specify
the single phase voltage when ordering.
Siemens Industry, Inc.
Industrial Controls Catalog
Factory Modifications
Selection
Ordering Information
䊳
Prices shown are additions to standard equipment prices as listed in the catalog and are not to be used as separate selling prices.
All modifications will consist of Siemens standard components as available. Standard equipment dimensions and enclosure construction
may not apply when certain modifications and special features are added.
Control Relays
Description
4 NO
2 NO/2 NC
4 NC
Under Voltage, Phase Failure, Phase Sequence, Phase Unbalance (460V)
Under Voltage, Phase Failure, Phase Sequence, Phase Unbalance (230V)
Under Voltage, Phase Failure, Phase Sequence, Phase Unbalance (575V)
Ground Fault Relay
Electronic On Delay Relay (.15s–100h) 24V/120V
Electronic On Delay Relay (.15s–100h) 24V/240V
Electronic Off Delay Relay (.15s–100s) 120V
Electronic Off Delay Relay (.15s–100s) 240V
24 hour time clock
24 hour time clock with day omission
7 day time clock
Compelling Relay
Acceleration Control
Deceleration Control
Control Relay
4-Poles Max
Class
Enclosure
Type
All
1, 3, 4, 7, 9, 12
Suffix
1, 3, 4, 7 & 9, 12
All
1, 3, 4, 7, 9, 12
LE, CLM, CM
All
30, 32
1, 4, 12
List
Price $
R40
R22
R04
R1
R2
R4
R5
T1
T2
T3
T4
T7
T8
T9
A6
A7
A8
Meters—Mounted on Enclosure
Description
Class
Ammeter (includes a C.T. if necessary)
Ammeter and Switch (3-Phase with 3 C.T.’s)
Voltmeter
Voltmeter and Switch (3-Phase)
Elapsed Time Meter
Wattmeter
14, 17, 18, 22,
25, 26, 36, 37, 40,
43, 83, 84
Enclosure
Type
1, 3, 4, 12
Suffix
List
Price $
M1
M2
M3
M4
M5
M6
Function Identification Plates
Description
Class
Suffix
Function identification plate, with marking as specified
All
N1
List Price $
Terminal Blocks
Description
3 Point Terminal
6 Point Terminal
9 Point Terminal
Class
Suffix
List Price $
TC3
TC6
TC9
All
Special Ratings
Description
Class
Suffix
Service Entrance Rating (Included as a standard feature for
product class 81, 84, 87, 88.)
17, 18, 25, 26, 32,
37
N3
Supplied mounted and unwired.
Not available on Class 36, 37.
Price x 2 Class 83 and 84.
Siemens Industry, Inc.
Industrial Controls Catalog
List Price $
ETM available with 120V coil
For terminal point more than
only.
9 terminals use
additional suffixes. Max 3 suffixes can be selected.
Product Category: NEMA
Available
3-Phase only.
8/99
Manual Control
Class SMF, MMS
Dimensions
Class SMF and MMS Open Type
NEMA Type 3R, 4 and 12
(Top and Bottom)
Class SMF
FO–1, 1P, 2, 2P
(with toggle operator)
Types
Class MMS
KO–1, 1A, 1B, 2, 2B, 2C
(with toggle operator)
Types
NEMA Type 1B General Purpose Flush Mounting
Device
Class
Fractional HP Starter
SMF
Motor Starting Switch
MMS
Type
FWN1, 1P, FWN2, 2P
FWN3, 3P, FW4, 4P
KWN1, 1A, 1B, KWN2, 2B, 2C
KWN3, 3A, 3B, KWN4, 4B, 4C
NEMA Type 4 Watertight Die Cast Zinc Enclosure
Device
Type of
Operator
Toggle
Dimensions in Inches (mm)
Type
A
B
C
FF1, 1P, 2, 2P
FS1, 1P, 2, 2P
1.44
(37)
1.44
(37)
1.44
(37)
1.44
(37)
1.75
(44)
1.75
(44)
1.75
(44)
1.75
(44)
2.75
(70)
3.50
(89)
2.75
(70)
3.50
(89)
2.75
(70)
3.50
(89)
2.75
(70)
3.50
(89)
4.50
(114)
5.25
(133)
4.50
(114)
5.25
(133)
4.50
(114)
5.25
(133)
4.50
(114)
5.25
(133)
FSJ1P, 2P
Class SMF
Fractional
HP Starter
Key
FF3, 3P, 4, 4P
FS3, 3P, 4, 4P
FSJ3P, 4P
Class
MMS
Motor
Starting
Switch
Toggle
KF1, 1A, 1B, 2, 2B, 2C
KS1, 1A, 1B, 2, 2B, 2C
KSJ1A, 1B, 2B, 2C
Key
KF3, 3A, 3B, 4, 4B, 4C
KS3, 3A, 3B, 4, 4B, 4C
KSJ3A, 3B, 4B, 4C
Dimensions in Inches (mm)
A
B
C
D
E
F
G
H
I
3.00
(76)
2.75
(70)
1.13
(28)
0.25
(6)
3.75
(95)
4.69
(119)
4.25
(108)
4.56
(116)
0.78
(20)
Device
Class
Type
Fractional HP Starter
Motor Starting Switch
SMF
MMS
FW1, 1P, 2, 2P
KW1, 1A, 1B, 2, 2B, 2C
NEMA Type 1 General Purpose Surface Mounting Enclosures
Standard Size—Class SMF and MMS
Types FG & KG (Single-Unit)
Note: Dimensions for reference, not for construction.
Dimensions are in inches (mm).
8/100
Oversized—Class SMF and MMS
Types FGJ & KGJ (Single-Unit)
Dimensions
1⁄ 2⬙– 3⁄ 4⬙
Jumbo MMSKE2
Knock-Out On Back and Sides
typical for key operator devices.
Siemens Industry, Inc.
Industrial Controls Catalog
Manual Control
Class SMF, MMS
Dimensions
NEMA Type 7 and 9 Cast Aluminum Enclosure
Dimensions in Inches (mm)
A
B
C
D
G
H
4.00
(101)
5.75
(146)
1.38
(35)
6.36
(161)
4.38
(111)
1.20
(30)
Device
Class
Type
Fractional HP Starter
Motor Starting Switch
SMF
MMS
FR1, FR2
KR1, KR2
NEMA Type 1 General Purpose Enclosure For Two Unit Devices
Type of
Operator
Class
Type
One Starter and
One Sel. Switch
Toggle
Key
Toggle
Key
Toggle
Key
SMF
SMF
SMF
SMF
SMF
SMF
Reversing Switch
Toggle
MRS
Two Speed Starter
Two Speed Switch
Toggle
Toggle
SMF
MMS
FG02, 02P
FG04P
FG222, 222P
FG44P
FG71, 71P, 72, 72P
FG74P
KG11, 11A, 11B, 22, 22A,
22B, 22C
FG11, 11P, 22, 22P
KG11, 11A, 11B, 22, 22B, 22C
Device
One Starter
Two Starters
NEMA Type 1B General Purpose Flush Mounting For Two Unit Devices
Device
Type of
Operator
Class
Type
FF22, 22P
Toggle
SMF
FS22P
Two
Starters
FF44P
Key
SMF
FS44P
FF71, 71P, 72, 72P
One
Starter
and One
Selector
Switch
Toggle
SMF
FS71P, 72P
FF74P
Key
SMF
FS74P
Reversing
Switch
Two
Speed
Switch
Two
Speed
Switch
A
B
C
D
5.25
(133)
4.56
(116)
5.25
(133)
4.56
(116)
5.25
(133)
4.56
(116)
5.25
(133)
4.56
(116)
3.75
(95)
3.50
(89)
3.75
(95)
3.50
(89)
0.75
(19)
3.50
(89)
3.75
(95)
3.50
(89)
5.25
(133)
4.50
(114)
5.25
(133)
4.50
(114)
5.25
(133)
4.50
(114)
5.25
(133)
4.50
(114)
1.44
(37)
1.44
(37)
1.44
(37)
1.44
(37)
2.00
(51)
2.00
(51)
2.00
(51)
2.00
(51)
Toggle
MRS
KF11, 11A, 11B
KF22, 22A
22B, 22C
5.25
(133)
3.75
(95)
5.25
(133)
1.75
(44)
Toggle
SMF
FF11, 11P, 22, 22P
5.25
(133)
3.75
(95)
5.25
(133)
1.44
(37)
Toggle
MMS
KF11, 11A, 11B
22, 22B, 22C
5.25
(133)
3.75
(95)
5.25
(133)
1.44
(37)
Note: Dimensions for reference, not for construction.
Dimensions are in inches (mm).
Selector
switch is on the left, increases overall depth
to 3.50 in. (89 mm).
one pilot light (located on right) is used on MRS
switches.
Only
Siemens Industry, Inc.
Industrial Controls Catalog
Dimensions include factory wired power connections.
Selector switch is on the left, extends 1.62 in. (41 mm)
from mounting surface.
8/101
Manual Control
Class 11 - 3RV
Dimensions
3RV102
Class 11 - NEMA 7 & 9, 3 & 4, and NEMA 7 & 9
Enclosure
Class 11 - NEMA 1 Enclosure
1/2 NPT
1/2 - 3/4 NPT
3/4 - 1 NPT
3/4 NPT
1/2 - 3/4 NPT
1/2 - 3/4 NPT
1/2 - 3/4 NPT
3/8 Mounting Screw
9.88
10.20
9.19
8.63
8.50
4.63
1/2 - 3/4 NPT
6.06
6.38
7.50
1/2 - 3/4 NPT
6.39
1/4 Mounting Screw
Typ. (3) Places
5.05
3/4 NPT
6.97
5.81
1/2 - 3/4 NPT
3/4 - 1 NPT
.50
Note: Dimensions in inches (millimeters). Dimensions
for reference, not for construction. Contact Sales
Office for dimensions not listed.
8/102
Siemens Industry, Inc.
Industrial Controls Catalog
Heavy Duty Motor Starters
Solid State Overload, Class 14
Dimensions
Figure 2
Figure 1
C
C1
.50
D2
C
B1
B
B1
C1
.50
D2
.50
B
CL
CL
J
A
D
E
J
A
D
L
M
M1
E1
D1
D1
B2
G
E1
Figure 5
Figure 4
B1
B1
.50
D2
K
M
M1
Figure 3
C
C1
L
G
C
B
B
C1
E2
.50
D2
CL
CL
J
J
A
D
A
D
L
K
M
M1
E1
L
G
D1
M
M1
E1
K
G
D1
Open Type Solid State Overload
Outline Dimensions
Mounting
Screw
Mounting Dimensions
Reset Dimensions
Size
Figure
A
B
B1
B2
C
C1
D
D1
D2
E
E1
E2
G
J
K
L
M
M1
00–13⁄4
1
7.44
3.50
5.75
—
3.75
3.50
6.50
2.00
0.19
6.27
1.00
—
#10
5.60
—
0.18
3.23
3.41
(189)
(89)
(146)
(95)
(89)
(165)
(51)
(5)
(159)
(25)
(87)
2–21⁄2
2
8.13
3.50
5.75
4.60
4.00
3.77
7.62
2.00
0.19
—
1.00
—
#10
(207)
(89)
(146)
(117)
(102)
(96)
(194)
(51)
(5)
—
3–31⁄2
4
5
6
3
4
5
6
9.78
4.50
6.75
(248)
(114)
(171)
11.06
4.50
6.75
(281)
(114)
(171)
12.76
5.71
6.89
(324)
(145)
(175)
13.03
6.30
7.48
(331)
(160)
(190)
—
—
5.19
4.66
9.22
1.44
0.28
(132)
(118)
(234)
(37)
(7)
5.75
4.66
10.34
1.44
0.44
(146)
(118)
(263)
(37)
(11)
8.54
—
7.09
4.72
—
(180)
(120)
(217)
—
9.29
(236)
—
7.09
5.12
(180)
(130)
(142)
(25)
—
0.72
—
(18)
—
—
(5)
(82)
6.87
0.48
0.18
3.88
4.06
(174)
(12)
(5)
(99)
(103)
0.25
8.43
0.48
0.18
4.04
4.22
(6)
(214)
(12)
(5)
(103)
(107)
0.72
0.72
0.25
9.35
0.48
0.18
4.04
4.22
(18)
(18)
(6)
(237)
(12)
(5)
(103)
(107)
—
—
0.35
—
—
—
—
—
—
—
—
—
—
(9)
—
—
—
—
0.35
(9)
Note: Dimensions in inches (millimeters). Dimensions
for reference, not for construction. Contact Sales
Office for dimensions not listed.
Siemens Industry, Inc.
Industrial Controls Catalog
8/103
Heavy Duty Motor Starters & Contactors
Ambient Compensated Bimetal Class 14
Dimensions
Figure 2
Figure 1
C1
C
B1
.50
D2
B1
C
B
D2
C1
CL
CL
J
A
A
D
J
D
3 PHASE
L
G
3 PHASE
L
SINGLE PHASE
M1
M
E
SINGLE PHASE
K
M1
M
G
Figure 3
E
D1
Figure 4
B1
B
.50
B
.50
.50
B
C
C1
C
C1
D2
B1
E1
D2
CL
A
J
D
J
D
A
L
L
RESET
R E S E T
G
E
D1
M1
M
B2
M1
M
G
E
D1
B2
Open Type Ambient Compensated Bimetal Overload
Size
Outline Dimensions
Figure A
B
B1
00–13⁄4 1
2–21⁄2
2
3–3 ⁄
3
4
4
12
7.45
(189)
8.38
(213)
10.66
(271)
12.02
(305)
3.50
(89)
3.50
(89)
4.50
(114)
4.50
(114)
5.75
(146)
5.75
(146)
6.75
(171)
6.75
(171)
C
C1
Mounting Dimensions
D
D1
D2
3.89
(99)
4.00
(102)
5.06
(129)
5.75
(146)
3.50
(89)
3.77
(96)
4.66
(118)
4.66
(118)
6.50
(165)
7.75
(197)
9.25
(235)
10.34
(263)
—
2.00
(51)
1.44
(37)
1.44
(37)
0.19
(4.8)
0.19
(4.8)
0.28
(7)
0.44
(11)
Mounting
Screw
G
E
E1
1.00
(25)
1.00
(25)
0.72
(18)
0.72
(18)
—
#10
—
#10
—
0.25
(6)
0.25
(6)
0.72
(18)
Reset Dimensions
J
K
L
M
M1
5.39
(137)
6.28
(160)
7.81
(198)
8.78
(223)
0.16
(4)
0.16
(4)
0.12
(3)
0.12
(3)
2.97
(75)
3.22
(82)
3.39
(86)
3.63
(92)
2.81
(71)
3.06
(78)
3.27
(83)
3.51
(89)
—
0.36
(9)
—
—
Note: Dimensions in inches (millimeters). Dimensions
for reference, not for construction. Contact Sales
Office for dimensions not listed.
8/104
Siemens Industry, Inc.
Industrial Controls Catalog
Reversing & Multispeed Heavy Duty Starters
Solid State Overload Class 22, 30
Dimensions
Figure 1
.50
D1
Figure 2
B1
C
B1
B
C1
B
Figure 3
B1
C
C1
B
D1
C1
.50
D1
.50
C
J
A
D
J
J
A
D
CL
D
A
CL
CL
L
K
K1
M1
G
B2
L
M
E
K
B2
M1
G
K1
K
K1
E
M
M1
G
M
E
Figure 4
Figure 5
B1
B1
B
.50
C
E
D1
C
E
.50
C1
D1
C1
J
A
J
D
D
A
L
L
K
K1
4.05
4.23
G
B
K
K1
M1
M
G
Figure 6
Figure 7
C
B1
E
.50
C
B1
E
C1
D1
C1
.50
D1
L3
J
A
D
A
J
D
L
K
K1
G
M1
B
L
M
K
K1
M1
G
B
M
Class 22 Reversing & Class 30 2 Speed/2 Winding
Size
00–13⁄4
2–21⁄2
3– 3 1⁄2
4
Figure
Outline Dimensions
A
B
B1
B2
C
1
2
3
4
7.69
8.94
11.44
11.91
3.62
3.62
—
—
3.92
4.17
5.65
6.22
7.75
8.25
10.94
10.94
10.50
10.50
12.75
12.75
C1
Mounting Dimensions
D
D1
E
Mounting
Screw
Reset Dimensions
G
J
K
K1
L
M
M1
3.61
3.98
5.03
5.12
7.25
8.50
10.75
11.22
#10
#10
#10
0.25
0.18
0.18
0.18
0.18
3.58
4.23
4.69
4.68
3.40
4.05
4.51
4.50
Mounting
Screw
Reset Dimensions
G
J
K
K1
L
M
M1
#10
#10
#10
#10
0.18
0.18
0.18
0.18
3.58
4.23
4.68
4.68
3.40
4.05
4.50
4.50
0.22
0.22
0.34
0.34
7.25
7.25
10.25
10.25
5.77
7.10
9.18
9.53
1.25
0.77
1.64
0.65
4.75
4.75
6.00
6.00
Class 30 2 Speed/1 Winding
Size
00–1 3⁄4
2–2 1⁄2
3–3 1⁄2
4
Figure
Outline Dimensions
A
B
B1
B2
C
C1
Mounting Dimensions
D
D1
E
1
5
6
7
7.69
9.19
11.44
11.91
3.62
—
—
—
3.92
3.94
5.65
6.22
3.61
3.85
5.07
5.12
7.25
8.75
10.75
10.75
7.75
14.55
16.94
16.94
10.50
16.30
18.75
17.75
0.22
0.22
0.34
0.82
7.25
13.00
16.25
16.25
5.77
7.33
9.18
9.06
1.25
0.77
1.64
1.64
4.75
5.75
6.00
6.00
Note: Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
Dimensions are in inches (mm).
Siemens Industry, Inc.
Industrial Controls Catalog
8/105
Reversing & Multispeed Heavy Duty Starters
Ambient Compensated Bimetal Overload Class 22, 30
Dimensions
Figure 1b
Figure 1a
B1
B1
B
.50
CL
.50
CL
C
C1
D1
B
.50
CL
.50
CL
CL
J
C
C1
D1
CL
J
A
A
D
NC
R
E
S
E
T
NC
R
E
S
E
T
M
A
N
T
R
I
P
X2
T1
T2
NC
T
R
I
P
T1
T2
T
R
I
P
T1
3
THIS OVERLOAD
USED ON
MULTISPEED
STARTERS ONLY
T2
M1
G
NC
R
E
S
E
T
M
A
N
X2
L
T
B2
K1
E
K
R
E
S
E
T
M
A
N
X2
T3
D
T
R
I
P
T1
T3
T2
Figure 2
B1
B
E
L
T
3
THIS OVERLOAD
USED ON
MULTISPEED
STARTERS ONLY
B2
K1
E
K
M
M
A
N
X2
M1
G
M
Figure 3
B1
B
E
C
C1
D1
C
D1
C1
.50
L
L
J
J
D
A
D
A
L
RESET
RESET
RESE T
RESE T
L
M1
M
G
K1
K
G
K
M1
M
K1
Figure 4
Figure 5
B1
B
B
C
C1
D1
B1
C
C1
D1
.50
CL
CL
CL
L
L
J
D
J
A
A
D
NC
L
NC
R
E
S
E
T
R
E
S
E
T
M
A
N
T
R
I
P
X
2
T1
T2
M
A
N
T1
T
3
T2
L
T3
K
K
K1
RESET
RESET
T
R
I
P
X
2
G
E
K1
M1
M
M1
M
G
E
Class 22 Reversing & Class 30 2 Speed/2 Winding with Bimetal Overload
Size
Figure
Outline Dimensions
A
B
B1
00–13⁄4
2–21⁄2
3–31⁄2
4
1a
1b
2
3
7.69
8.94
11.44
12.50
8.25
8.25
10.94
10.94
10.50
10.50
12.94
12.75
B2
C
3.62
3.62
—
—
3.92
4.17
5.66
6.22
C1
Mounting
Screw
D
D1
3.61
3.98
5.08
5.16
7.25
8.50
10.75
11.22
0.22
0.22
0.34
0.34
E
Mounting
Dimensions
G
Reset Dimensions
J
K
K1
L
M
M1
7.25
7.25
10.25
10.25
#10
#10
#10
0.25
5.60
6.46
8.56
9.11
4.75
4.75
6.00
6.00
0.16
0.16
0.12
0.12
3.12
3.10
3.83
4.09
3.07
3.05
3.71
3.97
E
Mounting
Dimensions
G
Reset Dimensions
J
K
K1
L
M
M1
7.25
13.00
16.25
#10
0.25
0.25
5.60
6.71
8.56
4.75
5.75
6.00
0.16
0.16
0.12
3.12
3.10
3.83
3.07
3.05
3.71
1.25
0.79
2.12
2.12
Class 30 2 Speed/1 Winding with Bimetal Overload
Size
Figure
Outline Dimensions
A
B
B1
00–13⁄4
2–21⁄2
3–31⁄2
1a
4
5
7.69
9.19
11.44
8.25
14.56
16.94
10.50
16.25
18.75
B2
C
C1
Mounting
Screw
D
D1
3.62
—
—
3.92
4.11
5.66
3.61
3.92
5.08
7.25
8.75
10.75
0.22
0.22
0.34
1.25
0.78
2.12
Note: Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
Dimensions are in inches (mm).
8/106
Siemens Industry, Inc.
Industrial Controls Catalog
Heavy Duty Contactors
Class 40
Dimensions
Full Voltage Open Type NEMA Contactor Size 00-8
Figure 1
Figure 2
Figure 3
Figure 4
Open Type
Mounting
Dimensions
Mounting
Screw
Size
3rd Character Outline Dimensions
of Catalog No. Fig
A
B
B1
B2
C
D
D1
E
G
00–13⁄4
2–21⁄2
3–31⁄2
4
C, D, E
F,G
H, I
J
1
1
1
1
4.31 (110)
4.88 (124)
6.13 (156)
7.81 (198)
3.94 (100)
3.94 (100)
5.13 (130)
5.19 (132)
4.25 (108)
4.25 (108)
5.50 (140)
5.50 (140)
4.75 (121)
—
—
—
3.75 (70)
4.00 (102)
5.06 (129)
5.75 (146)
3.94 (100)
4.50 (114)
5.63 (143)
6.56 (167)
0.19 (5)
0.19 (5)
0.25 (6)
0.81 (21)
1.00 (25)
1.00 (25)
0.75 (19)
0.75 (19)
#10
#10
0.25 (6)
0.5 (13)
5
6
L
M
2
2
N
P
3
4
5.71 (145)
6.3 (160)
8.27 (210)
17.23 (438)
6.89 (175)
7.48 (190)
—
—
—
—
—
—
8.54 (217)
9.29 (236)
9.53 (242)
10.56 (268)
7.09 (180)
7.09 (180)
9.80 (249)
12.28 (312)
4.72 (120)
5.12 (130)
2.83 (72)
—
—
—
—
5.35 (136)
0.35 (9)
0.35 (9)
7
8
8.27 (210)
8.43 (214)
14.05 (357)
15.41 (392)
Note: Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
Dimensions are in inches (mm).
Siemens Industry, Inc.
Industrial Controls Catalog
0.25 (6)
0.35 (9)
3rd
character of catalog number identifies contactor
rating.
8/107
Magnetic Reversing Contactors
Class 43
Dimensions
Figure 1
Figure 2
Open Type Horizontal Mounted
Size
00–13⁄4
2, 21⁄2
3–31⁄2
4
5
6
Fig.
1
1
1
1
2
2
Outline Dimensions
A
B
7.69 (195)
7.75 (197)
8.94 (227)
7.75 (197)
11.44 (291)
10.94 (278)
8.50 (216)
10.94 (278)
18.07 (459)
14.20 (361)
11.61 (295)
18.88 (480)
B1
9.25 (235)
9.25 (235)
11.50 (292)
11.50 (292)
—
9.45 (240)
C
3.88 (98)
4.56 (116)
5.19 (132)
6.25 (159)
9.44 (240)
10.85 (276)
C1
—
—
—
—
—
7.44 (189)
Mounting
Dimensions
D
7.25 (184)
8.5 (216)
10.75 (273)
7.81 (198)
17.20 (437)
10.44 (265)
D1
0.25 (6)
0.25 (6)
0.38 (6)
0.38 (6)
—
10.71 (272)
E
3.63 (92)
3.63 (92)
5.13 (130)
5.13 (130)
9.61 (244)
17.72 (450)
F
—
—
—
—
1.18 (30)
Mouning
Screw
G
#10
#10
0.25
0.25
—
—
Note: Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
Dimensions are in inches (mm).
8/108
Siemens Industry, Inc.
Industrial Controls Catalog
Overload Relays & Current Transformers
Solid State Overload
Dimensions
Dimensions “A” Frame—ESP200 Solid State Overload
Overload (55 - 630 Amps), SIRIUS 3RB20
Dimensions “A1” Frame—ESP200 Solid State Overload
Frame Size A
Frame Size A1
Frame Size B
Dimensions
Dimensions “B” Frame—ESP200 Solid State Overload
Current Transformers (all CT’s have the same dimensions)
mm
in.
mm
in.
mm
in.
A
80
3.15
80
3.15
100.4
3.95
B
12.6
0.5
12.6
0.5
8.6
0.34
C
27.7
1.1
28
1.10
32.6
1.28
D
44.85
1.77
44.85
1.77
44.85
1.77
E
34.9
1.37
34.9
1.37
23.5
0.93
F
19.6
0.77
19.6
.077
33.5
1.32
G
48.95
1.93
48.95
1.93
46.23
1.82
H
10.7
0.42
10.7
0.42
10.9
0.43
I
2.3
0.09
2.3
0.09
2.4
0.09
J
80
3.15
80
3.15
104.6
4.12
K
53.9
2.12
53.9
2.12
58.6
2.31
L
66.0
2.6
55.9
2.20
50
1.97
M
89.7
3.53
89.7
3.53
114
4.49
N
10.18
0.40
10.18
0.40
4.7
0.19
O
—
—
10.77
0.42
23.6
0.93
P
—
—
8.62
0.34
21.1
0.83
R
—
—
12.9
0.51
27.1
1.07
S
9.5
0.37
—
—
2.45
0.1
T
5.2
0.21
5.2
0.21
5.2
0.21
Note: When mounted on a plate, torque screws to
11 lb.in. (1.2 Nm).
Siemens Industry, Inc.
Industrial Controls Catalog
8/109
Overload Relays
Panel Mounted Class 48 — Bimetal
Dimensions
Figure 1
Figure 2
Figure 4
Figure 3
Figure 6
Figure 5
Figure 8
Figure 7
Mounting
Dimensions
Reset
Dimensions
C
D
E
J
K
L
3 3⁄16 (81)
3 3⁄16 (81)
3 9⁄16 (90)
3 9⁄16 (90)
3 (76)
3 (76)
3 1⁄2 (89)
3 1⁄2 (89)
1
13⁄4 (44)
27⁄16
27⁄16
3 (76)
3
1
3
1
Outline Dimensions
Mounting
Screw
G
Max
Wire
Size
Approx
Ship Wt
Lbs (Kg)
Ref
Dwg
#10
#10
#10
#10
8
1
00
250 MCM
2 (1)
2 (1)
3 (1)
4 (2)
D51820
D51830
D51833
D52206
Description
Amp
Rating
Fig
A
1-Pole
Bimetal
Ambient
Compensated
25
60
100
180
1
2
3
4
7
3 1⁄2 (89)
⁄8 (22)
4 7⁄8 (124) 7⁄8 (22)
4 7⁄8 (124) 1 1⁄4 (32)
5 15⁄16 (151) 1 1⁄4 (32)
Description
Amp
Rating
Fig
A
B
C
D
E
J
K
K1
K2
L
3-Pole
Bimetal
Ambient
Compensated
30
60
100
180
5
6
7
8
3 5⁄8 (92)
3 7⁄8 (98)
4 7⁄8 (124)
6 1⁄2 (165)
3 1⁄16 (78)
3 1⁄16 (78)
4 7⁄16 (113)
4 7⁄16 (113)
3 1⁄8 (79)
3 1⁄8 (79)
3 9⁄16 (90)
3 9⁄16 (90)
3 (76)
3 (76)
3 1⁄2 (89)
3 1⁄2 (89)
1 1⁄2 (38)
1 1⁄2 (38)
1 5⁄8 (41)
1 5⁄8 (41)
1 1⁄4 (32)
1 1⁄4 (32)
27⁄16 (62)
3 (76)
1 13⁄16 (46)
1 13⁄16 (46)
9
⁄16 (14)
9
⁄16 (14)
—
—
115⁄16 (49)
115⁄16 (49)
—
—
2 (51)
2 (51)
3
B
⁄2 (13)
⁄2 (13)
9
⁄16 (14)
9
⁄16 (14)
1
Mounting
Dimensions
Outline Dimensions
⁄4 (19)
⁄4 (19)
1
⁄2 (13)
1
⁄2 (13)
⁄8 (3)
⁄8 (3)
1
⁄8 (3)
1
⁄8 (3)
Reset
Dimensions
⁄16 (5)
⁄16 (5)
⁄8 (3)
1
⁄8 (3)
3
1
Mtg
Screw
G
Max
Wire
Size
Approx
Ship Wt Ref
Lbs (Kg) Dwg
#10
#10
#10
#10
8
2
00
250 MCM
3 (1)
3 (1)
4 (2)
5 (2)
D54791
D54823
D51868
D52038
Note: Dimensions for reference, not for construction.
Dimensions in inches (mm).
8/110
Siemens Industry, Inc.
Industrial Controls Catalog
Lighting & Heating Contactors
Electrically Held, Class LE
Dimensions
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Open Type Lighting and Heating Contactors
Outline Dimensions
Mounting Dimensions
Contact
Rating
Amps
20–30
20–30
20
Poles
2
3
4
Figure
2
2
1
A
3.36
3.97
3.62
B
2
2.25
2.87
B1
—
—
—
B2
—
—
—
C
2.69
2.88
2.88
C1
—
—
—
D
1.63
3.13
3.13
D1
—
3.25
3.25
E
1.63
1.81
1.78
20
20
8
12
3
3
3.62
3.62
—
—
3.71
—
—
4.55
2.88
2.88
2.97
2.97
3.13
3.13
3.25
3.25
1.78
1.78
60
30–60
30–60
100
200
300
400
3
6
9–12
3
3
3
3
2
4
4
6
5
5
5
4.06
3.87
5.25
5.19
6.77
8.27
8.43
2.88
6.15
18.62
4.00
4.72
5.71
6.3
—
—
—
—
5.91
6.89
7.48
—
—
—
—
—
—
—
3.06
3.06
3.31
4.75
7.09
8.54
9.29
—
—
—
—
—
—
—
3.13
3.18
4.62
4.63
5.12
7.09
7.09
3.25
—
—
4.37
3.94
4.72
5.12
2.25
—
18.00
2.88
—
—
—
Mounting
Screw
#10
#10
#10
#10
#10
#10
#10
0.281
#10
0.28
0.35
0.35
Note: Dimensions for reference, not for construction.
Dimensions in inches (mm).
Siemens Industry, Inc.
Industrial Controls Catalog
8/111
Lighting & Heating Contactors
Mechanically / Magnetically Held Lighting Contactors, Class CLM
Dimensions
CLM Contactor, 20 Amp
Figure 1
Figure 2
Figure 3
G
A
B
D
C
F
E
Open Type Lighting and Heating Contactors
Class
CLM
Figure
Number
Amp
Rating
Number of
Poles
A
B
C
D
E
F
G
1
1
2
2
2
2
2
2
3
30
30
60
60
100
100
200
200
30, 60
2–4
5
2, 3
4, 5
2, 3
4, 5
2, 3
4, 5
6-12
3.31 (84)
4.19 (106)
3.31 (84)
5.06 (129)
4.62 (117)
7.25 (184)
4.62 (117)
7.25 (184)
18.62
1.65 (42)
2.09 (53)
1.65 (42)
2.53 (64)
2.31 (59)
3.62 (92)
2.31 (59)
3.62 (92)
0.312
3.95 (100)
3.95 (100)
3.95 (100)
3.95 (100)
6.00 (152)
6.00 (152)
6.00 (152)
6.00 (152)
4.62
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
6.62 (168)
6.62 (168)
6.62 (168)
6.62 (168)
5.25
0.23 (6)
0.23 (6)
0.23 (6)
0.23 (6)
0.38 (10)
0.38 (10)
0.38 (10)
0.38 (10)
0.312
4.61 (117)
4.61 (117)
4.94 (125)
4.94 (125)
6.75 (171)
6.75 (171)
6.75 (171)
6.75 (171)
4.98
1.50 (38)
1.50 (38)
1.50 (38)
1.50 (38)
1.88 (48)
1.88 (48)
1.88 (48)
1.88 (48)
18.00
Note: Dimensions for reference, not for construction.
Dimensions in inches (mm).
8/112
Siemens Industry, Inc.
Industrial Controls Catalog
Lighting Control
Machanically Latched 300 and 400 Amps, Class CLM
Dimensions
CLM Contactors 300 Amp
CLM Contactors 400 Amp
Note: Dimensions for reference, not for construction.
Dimensions in inches (mm).
Siemens Industry, Inc.
Industrial Controls Catalog
8/113
Industrial Control Power Transformers
Class MT
Dimensions
Top View
Side View
Dimension “C” does not include the
added height required for secondary
fuse clips—0.50 in. (13 mm) maximum
for type “K” clips.
The Primary Fuse Kit, when installed, will
add a maximum of 0.69 in. (18 mm) to
the transformer “A” dimension and 1.94
in. (49 mm) to the “C” dimension.
A
2-pole Primary Class CC Fuse Block Kit is available
for field installation. See page 8/77 for details.
Catalog Number KCCFPX2R
Note: Dimensions for reference, not for construction.
Dimensions in inches (mm).
Class MT
Approximate Dimensions Inches (mm)
VA
Rating
50
75
100
150
200
250
300
350
500
750
1000
1500
2000
3000
5000
8/114
Approx
Voltage
Letters
A, B, C, D, E, F, I, M
G
H
J
L
A, B, C, D, E, F, I, M
G
H
J
A, B, C, D, E, F, I, M
G
H
J
L
A, B, C, D, E, F, I, M
G
H
J
L
A, B, C, D, E, F, I, M
G
H
J
A, B, C, D, E, F, I, M
G
H
J
L
A, B, C, D, E, F, I, M
G
H
J
A, B, C, D, E, F, I, M
G
H
J
L
A, B, C, D, E, F, I, M
G
H
J
L
A, B, E, F, I
G
H
L
A, E, I
G
H
A, I
G
H
A, I
G
H
A, I
G
H
A
G
H
A
3.00 (76)
3.13 (79)
3.00 (76)
3.25 (83)
4.00 (102)
3.50 (89)
3.38 (86)
3.13 (79)
3.50 (89)
3.38 (86)
3.69 (94)
3.88 (98)
3.63 (92)
4.63 (117)
4.00 (102)
4.19 (106)
4.25 (108)
4.38 (111)
4.44 (113)
4.00 (102)
4.25 (108)
4.25 (108)
4.50 (114)
4.38 (111)
4.75 (121)
4.75 (121)
5.25 (133)
5.86 (149)
4.75 (121)
5.25 (133)
5.13 (130)
5.13 (130)
5.25 (133)
8.25 (149)
5.00 (127)
5.38 (137)
5.63 (143)
5.50 (140)
6.00 (152)
5.88 (149)
6.86 (175)
7.00 (178)
7.00 (178)
7.38 (187)
7.00 (178)
5.63 (143)
7.86 (200)
7.13 (181)
7.50 (191)
6.75 (171)
7.50 (191)
8.25 (210)
7.00 (178)
8.25 (210)
7.56 (192)
7.50 (191)
8.00 (203)
8.63 (219)
10.0 (254)
10.50 (267)
13.50 (343)
B
3.00 (76)
3.00 (76)
3.00 (76)
3.00 (76)
3.38 (86)
3.00 (76)
3.38 (86)
3.38 (86)
3.38 (86)
3.38 (86)
3.38 (86)
3.38 (86)
3.75 (95)
3.38 (86)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
5.25 (133)
4.50 (114)
4.50 (114)
4.50 (114)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
6.75 (171)
5.25 (133)
6.38 (162)
6.38 (162)
6.75 (171)
6.75 (171)
6.75 (171)
6.75 (171)
6.75 (171)
9.00 (229)
9.00 (229)
9.00 (229)
9.00 (229)
9.00 (229)
9.00 (229)
9.00 (229)
C
2.56 (65)
2.56 (65)
3.00 (76)
2.56 (65)
2.88 (73)
2.56 (65)
2.88 (73)
2.88 (73)
2.88 (73)
2.88 (73)
2.88 (73)
2.88 (73)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
3.81 (97)
4.75 (121)
3.81 (97)
3.81 (97)
3.81 (97)
4.75 (121)
4.44 (113)
4.75 (121)
4.75 (121)
4.75 (121)
4.75 (121)
4.44 (113)
4.75 (121)
4.75 (121)
4.75 (121)
5.75 (146)
4.44 (113)
5.38 (137)
5.38 (137)
5.69 (144)
5.69 (144)
5.69 (144)
5.69 (144)
5.69 (144)
7.31 (186)
7.56 (192)
7.56 (192)
7.56 (192)
7.56 (192)
10.19 (259)
10.56 (268)
D
2.00 (51)
2.13 (54)
2.56 (65)
2.25 (57)
2.44 (62)
2.50 (64)
2.38 (60)
2.38 (60)
2.50 (64)
2.38 (60)
2.69 (68)
2.88 (73)
2.50 (64)
3.06 (78)
2.88 (73)
3.06 (78)
3.25 (83)
3.25 (83)
2.88 (73)
2.50 (64)
2.75 (70)
2.75 (70)
3.00 (76)
2.88 (73)
3.25 (83)
3.19 (81)
3.75 (95)
4.38 (111)
3.25 (83)
3.75 (95)
3.63 (92)
3.88 (98)
3.75 (95)
4.38 (111)
3.75 (95)
4.13 (105)
4.75 (121)
4.25 (108)
4.75 (121)
4.63 (117)
5.25 (133)
6.13 (156)
5.75 (146)
5.75 (146)
5.75 (146)
4.13 (105)
5.50 (140)
4.50 (114)
4.50 (114)
3.56 (90)
4.44 (113)
5.25 (133)
4.44 (113)
5.25 (133)
4.56 (116)
4.04 (103)
4.63 (117)
5.25 (133)
7.50 (190)
6.50 (165)
8.25 (210)
E
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
2.81 (71)
2.50 (64)
2.81 (71)
2.81 (71)
2.81 (71)
2.81 (71)
2.81 (71)
2.81 (71)
3.13 (79)
3.13 (79)
3.13 (79)
3.13 (79)
3.13 (79)
3.13 (79)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
4.38 (111)
3.75 (95)
3.75 (95)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
6.06 (154)
4.38 (111)
5.19 (132)
5.19 (132)
6.06 (154)
6.06 (154)
6.06 (154)
6.06 (154)
6.06 (154)
6.50 (165)
6.50 (165)
6.50 (165)
6.50 (165)
7.20 (183)
6.50 (165)
6.50 (165)
Mounting
Slots
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
5/16 (8) X 11/16 (17)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
13/64 (5) X 3/8 (10)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 9/16 (14)
9/32 (7) X 13/32 (10)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
9/32 (7) X 9/16 (14)
9/32 (7) X 9/16 (14)
9/32 (7) X 9/16 (14)
9/32 (7) X 9/16 (14)
9/32 (7) X 9/16 (14)
9/32 (7) X 9/16 (14)
7/16 (11) X 3/4 (19)
7/16 (11) X 3/4 (19)
7/16 (11) X 3/4 (19)
7/16 (11) X 3/4 (19)
7/16 (11) X 3/4 (19)
7/16 (11) X 3/4 (19)
Ship Wt
Lbs (Kg)
2.6 (1)
2.8 (1)
3.5 (2)
3.4 (2)
4.0 (2)
3.5 (2)
4.3 (2)
4.5 (2)
4.8 (2)
4.2 (2)
4.9 (2)
6.0 (3)
5.9 (3)
6.6 (3)
6.7 (3)
7.4 (3)
7.7 (4)
7.9 (4)
8.8 (4)
8.5 (4)
9.4 (4)
9.0 (4)
10.6 (5)
10.0 (5)
11.1 (5)
9.7 (4)
13.9 (6)
14.7 (7)
11.3 (5)
13.6 (6)
11.7 (5)
15.5 (7)
13.6 (6)
15.6 (7)
16.5 (8)
16.8 (8)
18.6 (8)
19.2 (9)
21.0 (9)
21.5 (10)
21.5 (10)
23.4 (11)
28.1 (13)
30.0 (14)
28.0 (13)
30.5 (14)
28.1 (13)
30.0 (14)
29.2 (13)
30.0 (14)
33.5 (15)
33.5 (15)
38.0 (17)
42.5 (19)
42.5 (19)
53.0 (24)
63.7 (29)
63.7 (29)
140.0 (64)
102.0 (46)
102.0 (46)
Siemens Industry, Inc.
Industrial Controls Catalog
Industrial Control Power Transformers
Class MTG
Dimensions
Top View
Side View
Dimension “C” does not include the
added height required for secondary
fuse clips—0.50 in. (13 mm) maximum
for type “K” clips.
The Primary Fuse Kit, when installed, will
add a maximum of 0.69 in. (18 mm) to
the transformer “A” dimension and 1.94
in. (49 mm) to the “C” dimension.
Note: Dimensions for reference, not for construction.
Dimensions in inches (mm).
Class MTG
Approximate Dimensions Inches (mm)
VA
Rating
50
75
100
150
200
250
300
350
500
750
1000
1500
2000
3000
5000
Voltage
Letters
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C, P
E, I
J
A
B, C
J
A
A
A
A
Siemens Industry, Inc.
Industrial Controls Catalog
A
3.38 (86)
3.25 (83)
3.38 (86)
3.25 (83)
3.50 (89)
3.25 (83)
3.50 (89)
3.63 (92)
3.63 (92)
3.63 (92)
3.63 (92)
4.38 (111)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.50 (114)
4.38 (111)
4.50 (114)
5.00 (127)
4.38 (111)
4.75 (121)
4.75 (121)
5.50 (140)
5.13 (130)
5.13 (130)
5.13 (130)
5.38 (137)
5.00 (127)
5.00 (127)
5.00 (127)
5.50 (140)
6.00 (152)
5.50 (140)
6.00 (152)
7.25 (184)
7.38 (187)
7.00 (178)
7.38 (187)
5.56 (141)
5.31 (135)
5.56 (141)
7.00 (178)
6.13 (156)
6.44 (164)
6.25 (159)
8.75 (222)
B
3.00 (76)
3.00 (76)
3.00 (76)
3.38 (86)
3.38 (86)
3.38 (86)
3.38 (86)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
5.25 (133)
6.38 (162)
6.38 (162)
6.38 (162)
6.38 (162)
6.75 (171)
6.75 (171)
9.00 (229)
9.00 (229)
C
3.00 (76)
3.00 (76)
3.00 (76)
3.25 (83)
3.25 (83)
3.25 (83)
3.25 (83)
3.50 (89)
3.50 (89)
3.50 (89)
3.50 (89)
3.50 (89)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.00 (102)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
4.50 (114)
7.19 (183)
5.31 (135)
7.19 (183)
7.19 (183)
7.50 (191)
7.50 (191)
9.38 (238)
9.38 (238)
D
2.50 (64)
2.25 (57)
2.50 (64)
2.25 (57)
2.50 (64)
2.25 (57)
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
3.19 (81)
2.50 (64)
2.50 (64)
2.50 (64)
2.81 (71)
3.19 (81)
2.81 (71)
3.19 (81)
3.50 (89)
3.19 (81)
3.19 (81)
3.19 (81)
4.06 (103)
3.75 (95)
3.75 (95)
3.75 (95)
4.25 (108)
3.75 (95)
3.75 (95)
3.75 (95)
4.25 (108)
4.75 (121)
4.25 (108)
4.75 (121)
6.00 (153)
5.75 (146)
5.38 (137)
5.75 (146)
4.38 (111)
4.06 (103)
4.31 (110)
5.75 (146)
4.94 (125)
5.25 (133)
4.56 (116)
6.50 (165)
E
2.50 (64)
2.50 (64)
2.50 (64)
2.81 (71)
2.81 (71)
2.81 (71)
2.81 (71)
3.13 (79)
3.13 (79)
3.13 (79)
3.13 (79)
3.13 (79)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
3.75 (95)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
4.38 (111)
5.31 (135)
5.31 (135)
5.31 (135)
5.31 (135)
6.13 (156)
6.13 (156)
6.50 (165)
6.50 (165)
Mounting
Slots
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
13/64 (5) X 15/32 (12)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
5/16 (8) X 11/16 (17)
9/32 (7) X 9/16 (14)
9/32 (7) X 9/16 (14)
7/16 (11) X 3/4 (19)
7/16 (11) X 3/4 (19)
Approx
Ship Wt
Lbs (Kg)
3.5 (2)
3.4 (2)
3.5 (2)
4.2 (2)
4.8 (2)
4.2 (2)
4.8 (2)
5.9 (3)
5.9 (3)
5.9 (3)
5.9 (3)
7.9 (4)
8.5 (4)
8.5 (4)
8.5 (4)
8.5 (4)
10.6 (5)
10.0 (5)
10.6 (5)
10.6 (5)
11.3 (5)
11.3 (5)
11.3 (5)
15.2 (7)
13.2 (6)
13.2 (6)
13.2 (6)
16.8 (8)
14.9 (7)
14.9 (7)
14.9 (7)
19.2 (9)
21.0 (9)
19.2 (9)
21.0 (9)
27.0 (12)
30.0 (14)
28.1 (13)
30.0 (14)
30.0 (14)
26.3 (12)
26.3 (12)
40.0 (18)
40.0 (18)
45.1 (21)
65.2 (30)
104.8 (48)
8/115
Heavy Duty Motor Starters & Contactors
Enclosed, Class 14, 40
Dimensions
Figure 2
Figure 1
K3
K2
K1
K3
K2
K2
K3
K1
K2
K2
K1
Figure 5
Figure 4
K3
K2
K1
K3
K2
K3
K3
K2
K2
Figure 3
D
A
K2
K2
D
A
K3
K3
D
A
E
B
G
D
A
E
B
G
G
C
K2
K2
C
K3
E
B
G
K3
K1
K3
E
B
C
View is typical for bottom and top
K3
K1
K2
C
K3
K1
K2
NEMA 1 General Purpose Enclosure (Standard width for use with or without CPT)햲
Size
Max
CPT
Size
00–13⁄4
2–21⁄2
3–31⁄2
4
5
6, 7
w/o CPT
w/o CPT
(100VA)
(300VA)
(300VA)
(300VA)
Figure
1
2
3
4
5
5
Mounting
Screw
Conduit Size
A
B
C
D
E
G
K1
K2
K3
K4
K5
Approx
Ship Wt
Lbs (Kg) Ref Dwg
1031⁄32 (279)
1317⁄32 (344)
191⁄8 (486)
247⁄8 (632)
40 (1016)
48 (1219)
613⁄32 (163)
731⁄32 (202)
113⁄8 (289)
133⁄8 (340)
20 (508)
20 (508)
51⁄32 (128)
63⁄8 (162)
711⁄16 (195)
81⁄8 (206)
11 (279)
121⁄2 (317)
8 7⁄32 (209)
101⁄4 (260)
155⁄8 (397)
213⁄4 (552)
375⁄8 (956)
453⁄16 (1148)
45⁄8 (117)
6 (152)
81⁄4 (210)
9 (229)
151⁄4 (387)
10 (254)
1
1
1
3
⁄4–1
1–11⁄4
11⁄2–2
2–21⁄2
1
⁄2–3⁄4
1
⁄2–3⁄4
—
—
—
—
11⁄4–11⁄2
11⁄4–11⁄2
—
—
—
—
2–3
2–21⁄2
10 (5)
15 (7)
26 (12)
37 (17)
135 (36)
150 (44)
K3
K4
K5
Approx
Ship Wt
Lbs (Kg) Ref Dwg
—
—
—
—
—
—
26 (12)
26 (12)
37 (17)
Outline Dimensions
Mounting Dimensions
⁄4
1
⁄4
1
⁄4
1
⁄4
1
⁄4
1
⁄4
⁄2
1
⁄2–3⁄4
1
⁄2–3⁄4
1
⁄2–3⁄4
2–3
2–21⁄2
⁄2–3⁄4
3
⁄4–1
1–11⁄4
11⁄4–11⁄2
11⁄4–11⁄2
11⁄4–11⁄2
D68870
D68870
D68870
D68870
D65608
D65608013
NEMA 1 General Purpose Enclosure (Extra wide for use with CPT)햲
Size
Max
CPT
Size
00–13⁄4 (200VA)
2–21⁄2 (200VA)
3–31⁄2 (250VA)
Outline Dimensions
Figure A
3
3
4
191⁄8 (486)
191⁄8 (486)
241⁄8 (632)
Mounting
Screw
Conduit Size
B
C
D
E
G
K1
K2
113⁄8 (289)
113⁄8 (289)
133⁄8 (340)
711⁄16 (195)
711⁄16 (195)
81⁄8 (206)
155⁄8 (397)
155⁄8 (397)
213⁄4 (552)
81⁄4 (210)
81⁄4 (210)
9 (229)
1
1
1
1
1–11⁄4
11⁄2–2
1–11⁄4
11⁄2–2
1–11⁄4–11⁄2 2–21⁄2
Note: Dimensions in inches (millimeters). Dimensions
for reference, not for construction. Contact Sales
Office for dimensions not listed.
8/116
Mounting Dimensions
⁄4
⁄4
1
⁄4
⁄2–3⁄4
⁄2–3⁄4
1
⁄2–3⁄4
D68870
D68870
D68870
햲 Clamshell
enclosure Size 00 - 4; Standard width and
Extra wide.
Siemens Industry, Inc.
Industrial Controls Catalog
Heavy Duty Motor Starters & Contactors
Enclosed, Class 14, 40
Dimensions
Figure 1
Figure 2
Figure 3
Figure 4
G
G
D
A
T R
T R
ESE
ESE
B
C MAX
K2
G
E
K1
Typical view
top and bottom
K3
NEMA 4X Fiberglass Enclosures (Standard width for use with or without CPT)
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
Mtg Screw Conduit Size
G
K1
K2
0–21⁄2
3–4
1
1
14.620 (371) 11.880 (302)
23.780 (604) 23.780 (604)
6.890 (175)
6.890 (175)
1⁄4
15.000 (381) 9.750 (248)
24.125 (612.7) 21.250 (539.7) 1⁄4
—
—
—
—
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
—
—
11 (4.9)
28 (12.7)
24-139-861-001
24-139-861-003
NEMA 7/9/3/4 Hazardous Location Enclosure (Standard width for use with or without CPT)
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
0–13⁄4 w/o CPT
2–21⁄2 (0–13⁄4 w/ CPT)
3
31⁄2–4
5
2
2
2
2
2
15.250 (387)
17.750 (451)
17.750 (451)
28.688 (729)
48.875 (1038)
10.000 (254)
10.375 (264)
10.375 (264)
11.750 (298)
14 7/8 (377)
8.500 (216)
10.625 (270)
10.625 (270)
18.375 (467)
29 (373)
10.688 (272)
14.688 (373)
14.688 (373)
17.750 (451)
22.875 (581)
9.125 (132)
13.250 (337)
13.250 (337)
15.750 (400)
213⁄5 (533)
Mtg Screw Conduit Size
G
K1
K2
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
⁄
⁄
3⁄4
3⁄4
3⁄4
33 (14.9)
60 (27.0)
60 (27.0)
140 (63.5)
352 (159)
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
34
⁄
60 (27.0)
Mtg Screw Conduit Size
G
K1
K2
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
⁄
⁄
1⁄4
—
—
—
—
—
—
12 (5)
18 (8)
49 (22)
Mtg Screw Conduit Size
G
K1
K2
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
⁄
⁄
1⁄4
3⁄8
3⁄8
3⁄8
—
—
—
—
—
—
—
—
—
—
—
—
Mtg Screw Conduit Size
G
K1
K2
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
⁄
⁄
1⁄4
—
—
—
—
—
—
17.5 (8)
36 (16)
67 (30)
Mtg Screw Conduit Size
G
K1
K2
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
⁄
⁄
⁄
5
⁄16
3⁄8
3⁄8
—
—
—
—
—
—
⁄
⁄
3⁄8
1⁄2
5⁄8
38
38
⁄
⁄
1⁄2
1⁄2
1⁄2
12
12
11⁄2
2
2
3
3
34
34
24-139-865-002
24-139-865-003
24-139-865-003
24-139-865-004
24-139-865-006
NEMA 7/9/3/4 Hazardous Location Enclosure (Extra wide for use with CPT)
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
Mtg Screw Conduit Size
G
K1
K2
0–21⁄2햲
2
17.750 (451) 14.688 (373)
10.375 (264)
10.625 (270) 13.250 (337)
38
⁄
⁄
12
2
24-139-865-003
NEMA 12/3/3R Industrial Use Enclosure (Standard width for use without CPT)
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
0–13⁄4
2–21⁄2
3–4
3
3
3
13.000 (330) 7.750 (197)
16.000 (406) 8.125 (206)
26.000 (660) 13.125 (333)
5.438 (138)
6.063 (154)
7.563 (192)
12.250 (311) 5.000 (127)
15.250 (387) 5.000 (127)
25.250 (641) 10.000 (254)
14
14
—
—
—
D41547
D41547
D41552
NEMA 12/3/3R Industrial Use Enclosure (Extra wide for use with CPT)
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
0–13⁄4
2–2 1⁄2
3–3 1⁄2
4
5
6, 7
3
3
3
3
4
4
13.000 (330)
16.000 (406)
26.000 (660)
29.063 (738)
40.000 (1016)
48.000 (1219)
5.375 (137)
6.125 (156)
7.563 (192)
9.250 (235)
11.000 (279)
12.500 (317)
12.250 (311)
15.250 (387)
25.250 (641)
27.563 (700)
41.000 (1041)
49.000 (1244)
12.625 (321)
13.250 (337)
13.125 (333)
23.188 (589)
20.000 (508)
20.000 (508)
10.000 (254)
11.000 (279)
10.000 (254)
20.000 (508)
10.000 (254)
10.000 (254)
14
14
—
—
—
—
—
—
30 (14)
33 (15)
49 (22)
64 (29)
D17150
D17150
D41552
D17150
D65608007
D65608009
NEMA 4/4X Stainless Steel Enclosure (Standard width for use without CPT)
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
0–13⁄4
2–21⁄2
3–4
3
3
3
13.000 (330) 7.750 (197)
16.000 (406) 8.125 (206)
26.000 (660) 13.125 (333)
5.438 (138)
6.063 (154)
7.563 (192)
12.250 (311) 5.000 (127)
15.250 (387) 5.000 (127)
25.250 (641) 10.000 (254)
14
14
—
—
—
D41546
D41546
D41551
NEMA 4/4X Stainless Steel Enclosure (Extra wide for use with CPT)
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
0–13⁄4
2–21⁄2
3–31⁄2
4
5 (Painted)
6, 7 (Painted)
3
3
3
3
4
4
13.000 (330)
16.000 (406)
26.000 (660)
29.000 (737)
40.000 (1016)
48.000 (1219)
5.375 (137)
6.000 (152)
7.563 (192)
9.250 (235)
11.000 (279)
12.500 (317)
12.250 (311)
15.250 (387)
25.250 (641)
27.500 (699)
41.000 (1041)
49.000 (1244)
12.625 (321)
13.250 (337)
13.125 (333)
23.188 (589)
20.000 (508)
20.000 (508)
Note: Dimensions in inches (millimeters). Dimensions
for reference, not for construction. Contact Sales
Office for dimensions not listed.
Siemens Industry, Inc.
Industrial Controls Catalog
10.000 (254)
11.000 (279)
10.000 (254)
20.000 (508)
10.000 (254)
10.000 (254)
14
14
14
—
—
—
—
—
—
—
—
—
—
—
—
30 (14)
33 (15)
67 (30)
64 (29)
D41917
D42935
D41551
D43292
D65608007
D65608009
for addition of only CPT on size 21⁄2. If pilot
devices are needed, use size 3-31⁄2 enclosure.
햲 Used
8/117
Combination Heavy Duty Starters
Enclosed, Class 17, 18
Dimensions
Figure 1
Figure 2
H
7.0
Typical view
top and bottom
3.0
3.0
H
Typical view
top and bottom
1/2
1 X 1 1/4
X 3/4
Knockout Knockout
6.00
(156)
B
1/2 X 3/4
1 1/2 X 2 Knockout 1 1/2 X 2
Knockout
Knockout
C
B
E
C
D
GA
GA
Mounting
Holes for
1/4" Screws
Qty. 3
E
Mounting
Holes for
1/4" Screws
Qty. 4
D
E
D
Figure 4
Figure 3
8.5
3.5 3.5
H
Typical view
top and bottom
1/2 X 3/4
1 1/2 X 2 Knockout 1 1/2 X 2
Knockout
Knockout
B
D
E
C
G
A
E
Mounting
Holes for
1/4" Screws
Qty. 4
D
NEMA 1 Standard Width 0–6
Mounting
Dimensions
Size
Figure
A
B
C
D
E
G
H
Approx
Ship Wt
Lbs (Kg)
Ref Dwg
0–2
21⁄2, 3
31⁄2, 4
5
6
1
2
3
4
4
24 (610)
24 (610)
36 (914)
72.156 (1833)
79.125 (2010)
11 (279)
20 (508)
24 (610)
20 (508)
22 (559)
8 (203)
8 (203)
8 (203)
11.031 (280)
13 (330)
6.125 (156)
15.00 (381)
14.00 (356)
71 (1803)
78 (1981)
2.125 (54)
2.125 (54)
5.00 (127)
16 (406)
18 (457)
21.00 (533)
21.00 (533)
33.50 (851)
—
—
3.50 (90)
3.50 (90)
5.00 (127)
—
—
35 (16)
48 (22)
101 (46)
250 (113)
275 (125)
D68774001
D68774002
D68774003
D56032005
D56032006
Ref Dwg
D68774002
D68774003
Outline Dimensions
NEMA 1 Extra Wide 0–3
Mounting
Dimensions
Size
Figure
A
B
C
D
E
G
H
Approx
Ship Wt
Lbs (Kg)
0–2
21⁄2, 3
2
3
24 (610)
36 (914)
20 (508)
24 (610)
8 (203)
8 (203)
15.00 (381)
14.00 (356)
2.125 (54)
5.00 (127)
21.00 (533)
33.50 (851)
3.50 (90)
5.00 (127)
48 (22)
101 (46)
Outline Dimensions
Note: Dimensions in inches (mm).
Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
8/118
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Heavy Duty Starters
Enclosed, Class 17, 18
Dimensions
Figure 2
Figure 1
5.50
(140)
Figure 3
B
B
C
E
B
D
E
C
D
C
H
G
E
Mounting Holes for
1/4" Screws Qty. 4
Mounting Holes for
1/4" Screws Qty. 3
D
AGH
AGH
A
Mounting Holes for
1/4" Screws Qty. 4
Figure 5
Figure 4
C
D
A
Mounting Holes for
No. 10 Screws Qty. 4
E
B
Mounting Holes for
G
3/8" screw. Qty. 4
NEMA 12/3/3R/4 (Painted), 4/4X (Stainless) Standard Width 0–6
Mounting
Dimensions
Size
Figure
A
B
C
D
E
G
H
Approx
Ship Wt
Lbs (Kg)
0–2
21⁄2, 3
31⁄2, 4
5 (Painted)
6 (Painted)
1
2
3
4
4
24 (610)
24 (610)
36 (914)
72.156 (1833)
79.125 (2010)
11 (279)
20 (508)
24 (610)
20 (508)
22 (559)
8 (203)
8 (203)
8 (203)
11.031 (280)
13 (330)
6.00 (152)
15.00 (381)
12 (305)
71 (1830)
78 (1981)
2.50 (64)
2.50 (64)
6.00 (152)
16 (406)
18 (457)
25.75 (654)
25.75 (654)
37.75 (959)
—
—
26.75 (680)
26.75 (680)
38.75 (984)
—
—
35 (16)
48 (22)
101 (46)
250 (113)
275 (125)
Ref Dwg
D56033
D56033
Outline Dimensions
Ref Dwg
D56033
D56033
D56033
D56032005
D56032006
NEMA 12/3/3R/4 (Painted), 4/4X (Stainless) Extra Wide 0–3
Mounting
Dimensions
Size
Figure
A
B
C
D
E
G
H
Approx
Ship Wt
Lbs (Kg)
0–2
2
3
24 (610)
36 (914)
20 (508)
24 (610)
8 (203)
15.00 (381)
12.00 (305)
2.50 (64)
6.00 (152)
25.75 (654)
37.75 (959)
26.75 (654)
38.75 (984)
49 (22)
102 (46)
Ref Dwg
—
—
—
Outline Dimensions
21⁄2, 3
8 (203)
NEMA 4X Fiberglass Standard Width 0–4
Mounting
Dimensions
Size
Figure
A
B
C
D
E
G
H
Approx
Ship Wt
Lbs (Kg)
0–13⁄4
2–31⁄2
4
5
5
5
23.75 (603)
23.75 (603)
39.37 (1000)
14.62 (371)
23.75 (603)
29.52 (750)
7.12 (181)
8.50 (216)
12.20 (310)
24.09 (612)
24.06 (611)
40.94 (1040)
12.20 (310)
21.30 (541)
27.95 (710)
—
—
—
—
—
—
42 (19)
44 (20)
55 (25)
Outline Dimensions
Note: Dimensions in inches (mm).
Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
Siemens Industry, Inc.
Industrial Controls Catalog
8/119
Combination Heavy Duty Starters
Enclosed, Class 18
Dimensions
Figure 1
RESET
OFF
TRIP
ON
A
D
T R
T R
ESE
ESE
B
G (Qty. 4)
C MAX
K2
K1
K3
E
Typical view bottom and top
NEMA 7 & 9, 3, 4 Standard Width 0–4
Outline Dimensions
Mounting
Dimensions
Mounting
Screw
Conduit Size
Size
Figure
A
B
C
D
E
G
K1
K2
K3
0–13⁄4
2–31⁄2
4
5
1
1
1
1
17.38 (441)
28.25 (718)
32.25 (819)
40.875 (1038)
14.69 (373)
17.75 (451)
20.00 (508)
22.875 (581)
10.38 (264)
11.19 (284)
11.50 (292)
14.875 (378)
10.63 (270)
18.38 (467)
22.50 (572)
29 (737)
13.25 (337)
15.75 (400)
17.75 (451)
21.75 (552)
3
3
2
21⁄2
21⁄2
3
1
⁄8
3
⁄8
5
⁄8
5
⁄8
⁄4
3
⁄4
3
⁄4
1
⁄2
⁄2
1
⁄2
1
⁄2
3
⁄4
Approx Ship
Wt Lbs (Kg)
Ref Dwg
60 (27)
160 (72)
250 (113)
360 (163)
24-139-865-003
24-139-865-004
24-139-865-005
—
Note: Dimensions in inches (mm). Dimensions for
reference, not for construction. Contact Sales
Office for dimensions not listed.
8/120
Siemens Industry, Inc.
Industrial Controls Catalog
Reversing Heavy Duty Starters & Contactors
Enclosed, Class 22, 43
Dimensions
K2
K2
K3
K1
Figure 4
Figure 3
Figure 2
Figure 1
K3
K1
G
D
A
D
D
A
T R
ESE
T R
A
ESE
B
G
G
E
B
E
B
C MAX
K2
C
C
E
K1
K3
K1
K3
K2
K1
K3
K2
View is typical for bottom and top
NEMA 1 General Purpose Enclosure (Standard width for use with and without CPT)
Mounting
Mounting Dimensions Screw
Conduit Size
B
C
D
E
G
K1
K2
K3
K4
Approx
Ship Wt
Lbs (Kg)
113⁄8 (289)
133⁄8 (340)
20 (508)
20 (508)
711⁄16 (195)
81⁄8 (206)
11 (279)
121⁄2 (317)
155⁄8 (397)
213⁄4 (552)
375⁄8 (956)
453⁄16 (1148)
81⁄4 (210)
9 (229)
151⁄4 (387)
10 (254)
1
1
1–11⁄4
11⁄4–11⁄2
11⁄4–11⁄2
11⁄4–11⁄2
11⁄2–2
2–21⁄2
1
⁄2–3⁄4
1
⁄2–3⁄4
—
—
11⁄4–11⁄2
11⁄4–11⁄2
30 (14)
52 (24)
135 (36)
150 (44)
Outline Dimensions
Size
Figure A
00–21⁄2 (200 VA)
3–4 (300 VA)
5 (300 VA)
6, 7 (300 VA)
1
2
191⁄8 (486)
247⁄8 (632)
40 (1016)
48 (1219)
⁄2–3⁄4
1
⁄2–3⁄4
2–3
2–21⁄2
⁄4
1
⁄4
1
⁄4
1
⁄4
Ref Dwg
D68870
D68870
D65608
D65608013
NEMA 4/4X Stainless Steel Enclosure (with or without CPT)
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
Mtg Screw Conduit Size
G
K1
K2
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
0–13⁄4
2–21⁄2
3–31⁄2 (w/o CPT)
3–31⁄2 (w/ CPT)
4
5 (Painted)
6, 7 (Painted)
3
3
3
13 (330)
16 (406)
251⁄16 (637)
125⁄8 (321)
131⁄4 (337)
173⁄16 (437)
53⁄8 (137)
6 (152)
73⁄8 (187)
121⁄4 (311)
151⁄4 (387)
245⁄16 (618)
10 (254)
11 (279)
14 (356)
14
3
29 (737)
233⁄16 (589)
91⁄4 (235)
271⁄2 (699)
20 (508)
40 (1016)
48(1219)
20 (508)
20 (508)
11 (279)
121⁄2 (317)
41 (1041)
49 (1244)
10 (254)
10 (254)
38
14
⁄
⁄
1⁄4
—
—
—
—
—
—
—
—
—
30 (14)
33 (15)
53 (24)
D41917
D42935
D17423
5 16
⁄
—
—
—
64 (29)
⁄
3⁄8
—
—
—
—
—
—
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
⁄
⁄
140
150
D43292
D65608007
D65608009
NEMA 7/9/3/4 Hazardous Location Enclosure (with or without CPT)
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
Mtg Screw Conduit Size
G
K1
K2
0–21⁄2
3–4
4
4
281⁄4 (718)
321⁄4 (819)
91⁄4 (235)
99⁄16 (243)
183⁄8 (467)
221⁄2 (572)
12
12
12
12
161⁄4 (413)
181⁄4 (464)
153⁄4 (400)
173⁄4 (451)
⁄
⁄
⁄
⁄
3
3
34
34
24-139-865-004
24-139-865-005
Note: Dimensions in inches (mm).
Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
Siemens Industry, Inc.
Industrial Controls Catalog
8/121
Reversing Heavy Duty Starters & Contactors
Enclosed, Class 22, 43
Dimensions
Figure 5
Figure 6
Figure 7
.188 5.00
12.50
10.00
1.20
48.00
45.75
2.38
.69
15.25
20.00
4-POINT MOUNTING
FOR .31 SCREWS
A
29.88
DOOR
OPEN
90°
.38 HOLE DIA.
FOR PADLOCK
A
B C B
11.62
16.50
7.25
K3
12.75
K2
10.00
0
K1
0.50
2.71
A COMB. K.O.’s FOR 1.00, 1.25, 1.50, 2.00, OR 2.50 CONDUIT
B COMB. K.O.’s FOR 1.00, 1.25, OR 1.50 CONDUIT
C COMB. K.O.’s FOR 0.50 OR 0.75 CONDUIT
View is typical for bottom and top
NEMA 12/3/3R Industrial Use Enclosure (with or without CPT)
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
Mtg Screw Conduit Size
G
K1
K2
0–13⁄4
2–21⁄2
3–31⁄2 (w/o CPT)
3–31⁄2 (w/ CPT)
4
5
6 (300 VA CPT max.)
5
5
5
13 (330)
16 (406)
251⁄16 (637)
125⁄8 (321)
131⁄4 (337)
173⁄16 (437)
53⁄8 (137)
61⁄8 (156)
73⁄8 (187)
121⁄4 (311)
151⁄4 (387)
245⁄16 (618)
10 (254)
11 (279)
14 (356)
14
5
291⁄16 (738)
233⁄16 (589)
91⁄4 (235)
279⁄16 (700)
7
7
40 (1016)
48 (1219)
20 (508)
20 (508)
11 (279)
121⁄2 (318)
41 (1041)
453⁄4 (1162)
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
14
⁄
⁄
⁄
—
—
—
—
—
—
—
—
—
30 (14)
33 (15)
53 (24)
20 (508)
5 16
⁄
—
—
—
64 (29)
10 (254)
10 (254)
38
⁄
1⁄4
—
—
—
—
—
—
14
D17150
D17150
D17150
D17150
D65608007
NEMA 4X Fiberglass Enclosure (with or without CPT)
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
Mtg Screw Conduit Size
G
K1
K2
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
0–21⁄2
3–4
6
6
23.78 (604)
23.78 (604)
6.89 (175)
6.89 (175)
224⁄5 (579)
224⁄5 (579)
14
⁄
⁄
—
—
35
38
14.68 (373)
23.78 (604)
134⁄5 (351)
224⁄5 (579)
14
—
—
—
—
—
—
Note: Dimensions in inches (mm).
Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
8/122
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Reversing Heavy Duty Starters
Enclosed, Class 25, 26
Dimensions
Figure 1
7.0
3.0
Figure 2
3.0
8.5
H
H
Typical view
top and bottom
1 1/2 X 2
Knockout
1/2 X 3/4
Knockout
1 1/2 X 2
Knockout
1 1/2 X 2
Knockout
C
D
Typical view
top and bottom
1/2 X 3/4
1
Knockout 1 /2 X 2
Knockout
B
E
Figure 3
3.5 3.5
B
D
E
C
G
A
GA
Mounting
Holes for
1/4" Screws
Qty. 4
E
E
D
Mounting
Holes for
1/4" Screws
Qty. 4
D
Figure 4
Figure 5
Figure 6
B
E
C
D
RESET
OFF
TRIP
ON
A
D
T R
T R
ESE
ESE
AGH
B
Mounting Holes
for 3/8" screws Qty. 4
C MAX
Typical view
top and bottom
K2
Mounting Holes for
1/4" Screws Qty. 4
K1
E
K3
NEMA 1 Standard Width 0–6
Mounting
Dimensions
Size
Figure
A
B
C
D
E
G
H
Approx
Ship Wt
Lbs (Kg)
0–21⁄2
3–4
5 (Painted)
6 (Painted)
1
2
3
3
24 (610)
36 (914)
72.156 (1833)
79.125 (2010)
20 (508)
24 (610)
20 (508)
22 (559)
8 (203)
8 (203)
11.031 (280)
13 (330)
15.00 (381)
14.00 (356)
71 (1803)
78 (1981)
2.125 (54)
5.00 (127)
16 (406)
18 (457)
21.00 (533)
33.50 (851)
—
—
3.50 (90)
5.00 (127)
—
—
60 (27)
121 (55)
250 (113)
275 (125)
D68774002
D68774003
D56032005
D56032006
Ref Dwg
D68774005
D68774006
D56032005
D56032006
Outline Dimensions
Ref Dwg
NEMA 12/3/3R/4 (Painted), 4/4X (Stainless) Standard Width 0–6
Mounting
Dimensions
Size
Figure
A
B
C
D
E
G
H
Approx
Ship Wt
Lbs (Kg)
0–21⁄2
3–4
5 (Painted)
6 (Painted)
5
5
3
3
24 (610)
36 (914)
72.156 (1833)
79.125 (2010)
20 (508)
24 (610)
20 (508)
22 (559)
8 (203)
8 (203)
11.031 (280)
13 (330)
15.00 (381)
12 (305)
71 (1803)
78 (1981)
3.50 (90)
6.00 (152)
16 (406)
18 (457)
25.75 (654)
37.75 (959)
—
—
26.75 (654)
38.75 (984)
—
—
63 (29)
124 (56)
250 (113)
275 (125)
Outline Dimensions
NEMA 4X Fiberglass 0–4
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
Mtg Screw Conduit Size
G
K1
K2
0–21⁄2
3–4
4
4
23.780 (604) 14.680 (373)
23.780 (604) 23.780 (604)
6.890 (175)
6.890 (175)
24.125 (612.7) 12.250 (311) 3⁄8
24.125 (612.7) 21.250 (539.7) 3⁄8
—
—
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
—
—
—
—
18 (8)
28 (12.7)
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
⁄
140 (63.5)
24-139-861-001
24-139-861-003
NEMA 7/9/3/4 Hazardous Location 0–4
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
Mtg Screw Conduit Size
G
K1
K2
0–21⁄2
3–4
6
28.688 (729) 17.750 (451)
11.750 (298)
18.375 (467) 15.750. (400)
3⁄8
1⁄2
Contact Sales Office
3
34
24-139-865-004
Note: Dimensions in inches (mm).
Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
Siemens Industry, Inc.
Industrial Controls Catalog
8/123
Two Speed Heavy Duty Starters
Enclosed, Class 30
Dimensions
Figure 1
K2
K1
Figure 1a
K2
K3
Figure 2
K3
K1
K1
K2
Figure 3
Figure 4
K3
D
A
D
A
D
A
E
B
G
D
A
G
E
B
G
C
E
B
K1
G
K1
C
K3
E
B
C
K3
K2
K2
C
K3
K1
K2
2 Speed 1 Winding
NEMA 1 General Purpose Enclosure (Standard width for use with or without CPT)
Size
Fig
Outline Dimensions
A
B
0–1 3⁄4 w/o CPT
0–1 3⁄4 (200 VA)
2–2 1⁄2
3–3 1⁄2
4
1
1a
2
2
3
19 1⁄8
24 7⁄8
16
18.31
29
(486)
(632)
(406)
(465)
(737)
11 3⁄8
13 3⁄8
17.13
21.19
23 3⁄16
C
(289)
(340)
(435)
(538)
(589)
7 11⁄16
8 1⁄8
7.63
7.38
9 1⁄4
K2
K3
Approx
Ship Wt
Lbs (Kg)
8 1⁄4 (210)
9
(229)
14
(355)
18
(457)
20
(508)
14
⁄
⁄
1⁄4
1⁄4
5⁄16
12 34
14
12 34
⁄–⁄
⁄–⁄
1⁄2–3⁄4
1 1⁄4 –1 1⁄2
—
1–1 1⁄4
1 1⁄4 –1 1⁄2
1 1⁄4 –1 1⁄2
1⁄2 –3⁄4
—
1 1⁄2–2
2–2 1⁄2
1 1⁄4 –1 1⁄2
1 1⁄2–2
—
26
52
39
60
61
(12)
(24)
(20)
(27)
(28)
D68870
D68870
D42932001
D72956002
D43292001
10
14
14
14
20
20
(254)
(355)
(355)
(355)
(508)
(508)
14
⁄
⁄
1⁄4
1⁄4
5⁄16
5⁄16
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
34
47
47
55
61
61
(15)
(21)
(21)
(25)
(28)
(28)
D41917000
10
14
14
14
20
(254)
(355)
(355)
(355)
(508)
14
Mounting Dimensions
D
E
(195)
(206)
(194)
(187)
(235)
15 5⁄8
21 3⁄4
15.25
17.56
27 1⁄2
(397)
(552)
(387)
(446)
(699)
Mtg
Screw
G
Conduit Size
K1
Ref Dwg
NEMA 4/4X Stainless Steel Enclosure (Standard width for use with or without CPT)
0–1 3⁄4
0–1 3⁄4
2–2 1⁄2
2–2 1⁄2
3–3 1⁄2
4
w/o CPT
w/ CPT
w/o CPT
w/ CPT
3
3
3
3
3
3
13
16
16
25 1⁄16
29
29
(330)
(406)
(406)
(637)
(737)
(737)
12 5⁄8
17 1⁄8
17 1⁄8
17 3⁄16
23 3⁄16
23 3⁄16
(321)
(435)
(435)
(437)
(589)
(589)
5 3⁄8
7 5⁄8
7 5⁄8
7 3⁄8
9 1⁄4
9 1⁄4
(137)
(194)
(194)
(187)
(235)
(235)
12 1⁄4
15 1⁄4
15 1⁄4
24 5⁄16
27 1⁄2
27 1⁄2
(311)
(387)
(387)
(618)
(699)
(699)
14
D43292001
D43292001
NEMA 12/3/3R Industrial Use Enclosure (Standard width for use with or without CPT)
0–1 3⁄4
0–1 3⁄4
2–2 1⁄2
2–2 1⁄2
3–4
w/o CPT
w/ CPT
w/o CPT
w/ CPT
3
3
3
3
3
13
16
16
25 1⁄16
29
(330)
(406)
(406)
(637)
(737)
12 5⁄8
17 1⁄8
17 1⁄8
17 3⁄16
23 3⁄16
(321)
(435)
(435)
(437)
(589)
5 3⁄8
7 5⁄8
7 5⁄8
7 3⁄8
9 1⁄4
(137)
(194)
(194)
(187)
(235)
12 1⁄4
15 1⁄4
15 1⁄4
24 5⁄16
27 1⁄2
(311)
(387)
(387)
(618)
(699)
⁄
⁄
⁄
1⁄4
5⁄16
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
34
47
47
55
61
(15)
(21)
(21)
(25)
(28)
⁄
—
—
—
—
—
—
28
(13)
14
14
D17150010
D17150010
D19673000
NEMA 4X Fiberglass Enclosure (Standard width for use with or without CPT)
0–2 1⁄2
3–4
4
4
23.780 (604)
39.37 (1000)
23.780 (604)
29.53 (750)
6.890 (175)
12.60 (320)
—
—
—
—
14
—
24139861003
24139861004
2 Speed 2 Winding
NEMA 1 General Purpose Enclosure (Standard width for use with or without CPT)
Size
Fig
Outline Dimensions
A
B
0–2 1⁄2 w/o CPT
0–2 1⁄2 (200 VA)
3–4 w/o CPT
1
1a
1a
19 1⁄8
24 7⁄8
24 7⁄8
(486)
(632)
(632)
11 3⁄8
13 3⁄8
13 3⁄8
(289)
(340)
(340)
C
Mounting Dimensions
D
E
7 11⁄16 (195)
8 1⁄8 (206)
8 1⁄8 (206)
15 5⁄8
21 3⁄4
21 3⁄4
(397)
(552)
(552)
8 1⁄4 (210)
9
(229)
9
(229)
Mtg
Screw
G
K2
K3
Approx
Ship Wt
Lbs (Kg)
14
⁄
⁄
1⁄4
12 34
14
12 34
⁄–⁄
⁄–⁄
1⁄2–3⁄4
1–1 1⁄4
1 1⁄4–1 1⁄2
1 1⁄4 –1 1⁄2
1 1⁄2–2
2–2 1⁄2
2–2 1⁄2
30
52
52
(14)
(24)
(24)
D68870
D68870
D68870
⁄
⁄
1⁄4
1⁄4
1⁄4
5⁄16
5⁄16
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
34
41
41
41
55
61
61
(15)
(19)
(19)
(19)
(25)
(28)
(28)
D43292001
D43292001
Conduit Size
K1
Ref Dwg
NEMA 4/4X Stainless Steel Enclosure (Standard width for use with or without CPT)
0–1 3⁄4 w/o CPT
0–1 3⁄4 w/ CPT
2–2 1⁄2 w/o CPT
2–2 1⁄2 w/ CPT
3–3 1⁄2 w/o CPT
3–3 1⁄2 w/ CPT
4
3
3
3
3
3
3
3
13
16
16
16
25 1⁄16
29
29
(330)
(406)
(406)
(406)
(637)
(737)
(737)
12 5⁄8
17 1⁄8
13 1⁄4
17 1⁄8
17 3⁄16
23 3⁄16
23 3⁄16
(321)
(435)
(337)
(435)
(187)
(589)
(589)
5 3⁄8
7 5⁄8
6
7 5⁄8
7 3⁄8
9 1⁄4
9 1⁄4
(137)
(194)
(152)
(194)
(187)
(235)
(235)
12 1⁄4
15 1⁄4
15 1⁄4
15 1⁄4
24 5⁄16
27 1⁄2
27 1⁄2
(311)
(387)
(387)
(387)
(618)
(699)
(699)
10
14
11
14
14
20
20
(254)
(355)
(279)
(355)
(355)
(508)
(508)
14
10
14
11
14
14
20
(254)
(355)
(279)
(355)
(355)
(508)
14
14
NEMA 12/3/3R Industrial Use Enclosure (Standard width for use with or without CPT)
0–1 3⁄4 w/o CPT
0–1 3⁄4 w/CPT
2–2 1⁄2 w/o CPT
2–2 1⁄2 w/CPT
3–3 1⁄2 w/o CPT
3–4 w/CPT
3
3
3
3
3
3
13
16
16
16
25 1⁄16
29 1⁄16
(330)
(406)
(406)
(406)
(637)
(738)
12 5⁄8
17 1⁄8
13 1⁄4
17 1⁄8
17 3⁄16
23 3⁄16
(321)
(435)
(337)
(435)
(187)
(589)
5 3⁄8
7 5⁄8
6 1⁄8
7 5⁄8
7 3⁄8
9 1⁄4
(137)
(194)
(156)
(194)
(187)
(235)
12 1⁄4
15 1⁄4
15 1⁄4
15 1⁄4
24 5⁄16
27 9⁄16
(311)
(387)
(387)
(387)
(618)
(700)
⁄
⁄
1⁄4
1⁄4
1⁄4
5⁄16
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
34
41
41
41
55
61
(15)
(19)
(19)
(19)
(25)
(28)
⁄
—
—
—
—
—
—
28
(13)
14
D17150010
D17150010
D19673000
NEMA 4X Fiberglass Enclosure (Standard width for use with or without CPT)
0–2 1⁄2
3–4
4
4
23.780 (604)
39.37 (1000)
23.780 (604)
29.53 (750)
6.890 (175)
12.60 (320)
—
—
—
—
14
—
24139861003
24139861004
Note: Dimensions in inches (mm). Dimensions for reference, not for construction. Contact sales office for dimensions not listed.
8/124
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Two Speed Heavy Duty Starters
Enclosed, Class 32
Dimensions
Figure 2
Figure 1
7.0
3.0
3.0
8.5
3.5 3.5
H
H
Typical view
top and bottom
1/2 X 3/4
Knockout
1 1/2 X 2
Knockout
Typical view
top and bottom
1/2 X 3/4
1 1/2 X 2 Knockout 1 1/2 X 2
Knockout
Knockout
1 1/2 X 2
Knockout
B
E
C
D
B
D
E
C
G
GA
A
Mounting
Holes for
1/4" Screws
Qty. 4
E
E
D
Mounting
Holes for
1/4" Screws
Qty. 4
D
Figure 4
B
Figure 3
E
C
D
AGH
Mounting Holes for
1/4" Screws Qty. 4
NEMA 1 Standard Width 0–4
Mounting
Dimensions
A
B
C
D
E
G
H
Approx
Ship Wt
Lbs (Kg)
24 (610)
36 (914)
24 (610)
36 (914)
20 (508)
24 (610)
20 (508)
24 (610)
8 (203)
8 (203)
8 (203)
8 (203)
15.00 (381)
14.00 (356)
15.00 (381)
14.00 (356)
2.125 (54)
5.00 (127)
2.125 (54)
5.00 (127)
21.00 (533)
33.50 (851)
21.00 (533)
33.50 (851)
3.50 (90)
3.50 (90)
3.50 (90)
3.50 (90)
68 (31)
71 (32)
135 (61)
138 (63)
D68774
D68774
D68774
D68774
2.50 (64)
6.00 (152)
2.50 (64)
6.00 (152)
25.75 (654)
37.75 (959)
25.75 (654)
37.75 (959)
26.75 (680)
38.75 (984)
26.75 (680)
38.75 (984)
68 (31)
71 (32)
135 (61)
138 (63)
D68774
D68774
D68774
D68774
Outline Dimensions
Size
0–13⁄4
2–4
0–21⁄2,
3–4
Figure
(1 Winding)
(1 Winding)
(2 Winding)
(2 Winding)
1
2
1
2
Ref Dwg
NEMA 12/3/3R/4 (Painted), 4/4X Stainless Standard Width 0–4
0–13⁄4
2–4
0–21⁄2,
3–4
(1 Winding)
(1 Winding)
(2 Winding)
(2 Winding)
4
4
4
4
24 (610)
36 (914)
24 (610)
36 (914)
20 (508)
24 (610)
20 (508)
24 (610)
8 (203)
8 (203)
8 (203)
8 (203)
15.00 (381)
12 (305)
15.00 (381)
12 (305)
Nema 4X Fiberglass 0–4
Size
Figure
Outline Dimensions
A
B
C
Mounting Dimensions
D
E
0–13⁄4
2–4
3
3
23.780 (604) 14.680 (373)
23.780 (604) 23.780 (604)
6.890 (175)
6.890 (175)
24.125 (613) 12.250 (311)
24.125 (613) 21.250 (540)
Mtg Screw Conduit Size
G
K1
K2
1
⁄4
⁄4
1
—
—
—
—
K3
Approx Ship Wt
Lbs (Kg)
Ref Dwg
—
—
18 (8)
28 (13)
—
—
Note: Dimensions in inches (mm).
Dimensions for reference, not for construction.
Contact sales office for dimensions not listed.
Siemens Industry, Inc.
Industrial Controls Catalog
8/125
Reduced Voltage Starters
Class 36, 37
Dimensions
Figure 1
Figure 2
C
H
B
K
L
Handle
(Optional)
C
A
D
A
Mounting Hole
for 1/4" screw
E
B
J
(4) .687 Dia Holes
Restricted Area
for
Auto Transformer
D
G
E
Class 36, 37, NEMA 1, 4, 4X, 12/3R, Combination and Non-combination
Reduced Voltage
AutoTransformer
Size
1 3/4 –2 1/2
3–3 1/2
4
5, 6
8/126
Part Winding & Wye Delta
Circuit
Disconnect Breaker
0–2
0–2 1/2
2 1/2 –3 1/2
3–3 1/2
4
4
5, 6
5, 6
Figure
1
1
1
2
A
43 5/16
55 5/16
74 21/32
90
B
24 5/32
28 9/32
28 9/32
29 30/31
C
11
11
11
20
D
42 11/32
54 11/32
73 13/32
16
E
20
24
24
24 7/16
G
—
—
—
2 16/21
H
—
—
—
1 23/40
I
—
—
—
—
J
—
—
—
1 1/8
K
—
—
—
8 3/40
L
—
—
—
3
Siemens Industry, Inc.
Industrial Controls Catalog
Duplex Heavy Duty Controllers
Class 83, 84
Dimensions
Figure 1
Figure 2
Figure 3
A
Class 83 Non-Combination Type
Enclosure
Type
NEMA 1
NEMA 12
NEMA 4/4X
Size
0–13⁄4
2, 21⁄2
3–4
0–13⁄4
2, 21⁄2
3–4
0–13⁄4
2, 21⁄2
3–4
Outline Dimensions
Figure A
B
1
19 1⁄2
16 1⁄8
1
25 1⁄16
17 3⁄16
1
29 11⁄16
23 3⁄16
2
19 1⁄2
16 1⁄8
2
25 1⁄16
17 3⁄16
2
231⁄2
23 3⁄16
2
19 1⁄2
16 1⁄8
2
25 1⁄16
17 3⁄16
2
29 1⁄16
23 3⁄16
C
6 1⁄2
7 3⁄8
9 1⁄4
6 1⁄2
7 3⁄8
11 1⁄4
6 1⁄2
7 3⁄8
9 1⁄4
Mounting
Dimensions
D
18 3⁄4
24 5⁄16
27 9⁄16
18 3⁄4
24 5⁄16
27 9⁄16
18 3⁄4
24 5⁄16
27 9⁄16
C
79⁄16
911⁄16
79⁄16
Mounting
Dimensions
D
33
5413⁄16
33
E
13
14
20
13
14
20
13
14
20
Mounting
Screw
G
1⁄4
1⁄4
5⁄16
1⁄4
1⁄4
5⁄16
1⁄4
1⁄4
5⁄16
Conduit Size
K1
K2
1⁄2–3⁄4
11⁄4–11⁄2
1⁄2–3⁄4
11⁄4–11⁄2
2–21⁄2
11⁄4–11⁄2
—
—
—
—
—
—
—
—
—
—
—
—
E
20
241⁄4
20
Mounting
Screw
G
3
⁄8
3⁄8
3⁄8
Conduit Size
K1
K2
7⁄8–11⁄8
7⁄8–11⁄8
—
—
—
—
K3
1⁄2
1⁄2–3⁄4
1⁄2–3⁄4
—
—
—
—
—
—
K4
1⁄2–3⁄4
11⁄4–11⁄2
11⁄4–11⁄2
—
—
—
—
—
—
K5
11⁄4–11⁄2
11⁄2–2
2–21⁄2–3
—
—
—
—
—
—
Approx
Ship Wt
Lbs
20
57
93
20
57
93
20
57
93
K5
123⁄64–123⁄32
—
—
Approx
Ship Wt
Lbs
70
106
—
Class 84 Combination Type
Enclosure
Type
NEMA 1
NEMA 4/4X/12
Size
0–21⁄2
3–4
0–4
Outline Dimensions
Figure A
B
3
341⁄8
245⁄8
3
56
281⁄2
3
341⁄8
245⁄8
Dimensions
may vary for size 3 & 4
stainless steel enclosures.
Siemens Industry, Inc.
Industrial Controls Catalog
NEMA
K3
11⁄8–123⁄64
—
—
K4
11⁄8–123⁄64
—
—
4 Painted, 4X Stainless Steel.
8/127
Pump Control Panels
Class 81, 87, 88
Dimensions
Outline Drawings
Figure 2
Figure 1
F
Opening for
Conduit Hub
Size "P"
C
B
E
F
Figure 3
5.000
C
D
A
A
G
D
B
F
Mounting Hole
for 1/4" screw
C
F
E
B
6.000
Figure 4
DG
A
C
Mounting Hole
For 3/8" screw
H
B
K
L
Handle
(Optional)
A
L
L
M
Mounting Holes
For 5/16" Hardware
N
H
I
J
J
K
(4) .687 Dia Holes
D
F
G
E
Class 81 Pump Panel
Size
Figure
A
B
C
D
E
F
G
H
I
J
K
Conduit Knockout
L
M
N
25-50 Amp
>50 Amp
1
1
281/2
281/2
11
20
81/16
81/16
24
24
7
7
51/2
10
27
27
3
51/2
51/2
81/2
8
111/2
—
141/2
11/4 x 1
1/ x 3/
2
4
1/ x 3/
2
4
11/4 x 1
1/
2
3/
4
Hub
P
x 3/4
x1
11/2
11/2
Class 87 Standard and Vacuum Starter Pump Panel
Size
Figure
A
B
C
D
E
F
G
H
I
J
K
1 – 21/2
3–4
5
6
4 (Vac)
1
1
2
2
2
281/2
401/2
725/32
791/8
5531/32
20
24
20
22
243/8
81/16
83/32
10
1215/16
922/32
24
36
71
78
5426/32
—
—
16
18
201/4
10
12
21/8
21/8
21/8
27
39
7029/32
777/8
5423/32
51/2
87/16
81/2
1115/16
111/2
157/16
141/2
—
—
—
—
—
—
5
D
42 11/32
54 11/32
73 13/32
16
E
20
24
24
24 716
—
263/16
—
—
Conduit Knockout
L
M
Hub
P
N
1/ x 3/
11/4 x 1
2
4
131/32 x 215/32 7/8 x 11/8
3/
4
—
—
—
—
—
—
—
—
2714/32
—
—
—
—
x1
—
11/2
21/2
—
Class 88 Reduced Voltage Pump Panels
RVAT
Size
2–2 1/2
3–3 1/2
4
5, 6
Part Winding & Wye Delta
Fusible
Circuit
Disconnect Breaker
1–2
1–2 1/2
2 1/2–3 1/2
3–3 1/2
4
4
5, 6
5, 6
Figure
3
3
3
4
A
43 5/16
55 5/16
74 21/32
90
B
24 5/32
28 9/32
28 9/32
30
C
11
11
11
20
F
2 1/16
2 1/8
2 1/8
2 3/4
H
—
—
—
1 1/2
I
—
—
—
—
J
—
—
—
1 1/8
K
—
—
—
8 1/16
L
—
—
—
3
Note: Dimensions in inches (millimeters). Dimensions
for reference, not for construction. Contact Sales
Office for dimensions not listed.
8/128
Siemens Industry, Inc.
Industrial Controls Catalog
Lighting Contactors
LE, CLM, CM
Dimensions
Figure 2
Figure 1
Figure 3
Figure 4
Figure 5
G
K3
K2
K1
K2
K2
K2
K2
D
A
B
K2
K2
C
E
B
G
GA
C
K1
K2
K2
K3
E
K2
K3
D
Enclosed Class LE, CLM, CM
Non-Combination
without
CPT
NEMA 1
with CPT
without
CPT
NEMA
12/3R &
4/4X
with CPT
Mounting
Dimensions
Mtg
Screw
Conduit Size
C
D
E
G
K1
613⁄32
51⁄32
87⁄32
45⁄8
1
⁄4
1
1
1317⁄32
16
731⁄32
171⁄8
63⁄8
75⁄8
101⁄4
151⁄4
6
14
1
⁄4
1
⁄4
1
⁄2–3⁄4
1
⁄2–3⁄4
1
191⁄8
113⁄8
711⁄16
155⁄8
81⁄4
1
⁄4
200A (2-5p)
—
300–400A (2-5p)
1
5
2
247⁄8
26
48
133⁄8
175⁄8
20
81⁄8
121⁄2
121⁄2
213⁄4
253⁄16
453⁄16
9
151⁄2
10
1
⁄4
1
⁄4
1
⁄4
1
20A (2–12p),
30A (2–5p)
1
191⁄8
113⁄8
711⁄16
155⁄8
81⁄4
1
⁄4
30–60A (6–12p)
—
100-200A (2-5p)
300–400A (2-5p)
20A (2–12p),
30A (2–5p)
30A (6–12p)
60-100A (2-5p)
60A (6–12p)
3
1
5
2
16
247⁄8
26
48
171⁄8
133⁄8
175⁄8
20
75⁄8
81⁄8
121⁄2
121⁄2
151⁄4
213⁄4
253⁄16
453⁄16
14
9
151⁄2
10
1
⁄4
⁄4
1
⁄4
1
⁄4
1
1
1
5
16
13 ⁄4
1
6 ⁄8
15 ⁄4
3
5
2
16
16
19
171⁄8
13
22
75⁄8
91⁄2
8
151⁄4
151⁄8
—
5
26
131⁄8
79⁄16
200A (2-5p)
300–400A (3p)
20A (2–12p),
30A (2-5p)
30A (6-12p)
5
4
26
48
175⁄8
20
5
16
3
—
60-100A (2-5p)
60A (6-12p)
200A (3p)
300–400A (3p)
LE
Lighting
Rating
CLM
Lighting
Rating
Fig
A
B
20A (2–12p),
30–60A (3p)
—
—
30–60A (6–12p),
100A (3p)
—
200–400A (3p)
—
20A (2–12p),
30–60A (3–9p),
100A (3p)
—
30–60A (12p)
200–400A (3p)
—
20A (2–12p),
30-60A (3p)
—
—
—
30–60A (6–12p),
100A (3p)
200–400A (3p)
—
20A (2–12p),
30–60A (3p)
—
30–60A (6–12p),
100A (3p)
—
—
200–400A (3p)
—
30–60A (2-5p)
1
1031⁄32
20A (2–12p)
30–60A (6-12p)
1
3
100A (2-5p)
Outline Dimensions
K3
K4
K5
3
⁄4–1
—
—
3
⁄4–1
11⁄4–11⁄2
1–11⁄4
11⁄4–11⁄2
—
—
—
—
1
⁄2–3⁄4
1–11⁄4
11⁄2–2
—
—
⁄2–3⁄4
1
⁄2–3⁄4
2–21⁄2
11⁄4–11⁄2
11⁄4–11⁄2
11⁄4–11⁄2
21⁄2
11⁄4–11⁄2
1
⁄2–3⁄4
—
—
11⁄4–11⁄2
—
—
2–21⁄2
1
⁄2–3⁄4
1–11⁄4
11⁄2–2
—
—
⁄2–3⁄4
⁄2–3⁄4
—
2–21⁄2
11⁄4–11⁄2
11⁄4–11⁄2
11⁄4–11⁄2
11⁄4–11⁄2
11⁄4–11⁄2
2–21⁄2
11⁄4–11⁄2
1
⁄2–3⁄4
—
—
11⁄4–11⁄2
—
—
—
2–21⁄2
11
1
⁄4
—
—
—
—
—
14
11
1
⁄4
1
⁄4
—
—
—
—
—
—
—
—
—
—
251⁄4
10
1
⁄4
—
—
—
—
—
121⁄2
121⁄2
233⁄16
49
151⁄2
10
1
⁄4
1
⁄4
—
—
—
—
—
—
—
—
—
—
131⁄4
61⁄8
151⁄4
11
1
⁄4
—
—
—
—
—
16
171⁄8
75⁄8
151⁄4
14
1
⁄4
—
—
—
—
—
5
26
13 ⁄8
9
7 ⁄16
25 ⁄4
10
1
⁄4
—
—
—
—
—
5
2
5
4
16
19
26
48
13
22
175⁄8
20
91⁄2
8
121⁄2
121⁄2
151⁄8
11
1
⁄4
—
—
—
—
—
253⁄16
49
151⁄2
10
1
⁄4
⁄4
—
—
—
—
—
—
—
—
—
—
E
G
LE, CM
Combination
NEMA
with &
12/3R & without
4/4X
CPT
Type
Fusible and Non-fusible
Disconnect
Circuit Breaker
Siemens Industry, Inc.
Industrial Controls Catalog
1
1
1
1
1
⁄2
K2
⁄2–3⁄4
Outline Dimensions
Lighting Ratings Fig
A
B
C
20–60A
100A
200A
300A
20–100A
24
24
46
76
24
11
20
20
22
11
8
8
10
13
8
3
3
3
3
3
D
K1
K2
K3
8/129
Manual Control
Class 11 - 3RV, SMF, MMS
Wiring Diagrams
Signaling Contact
for Class 11 - 3RV
Class 11 - 3RV
Typical Wiring Diagrams—Class SMF
3RV1921-1M
Typical Wiring Diagrams—MMS
AC Reversing Manual Starter and
Manual Motor Starting Switches
L3
T3
L1
T1
L1
T2
L2
T2
L2
T3
L3
T3
L3
REV
FWD
COM
T1
REVERSING
SINGLE PHASE
3-LEAD
REPULSION-INDUCTION
MOTOR
Reversing Manual Motor
Starting Switch 2-Pole, 1-Phase
T1
L1
L3
T3
L1 L2 L3
L2
LOW
L1
L3
T3
Pilot Lights
(if used)
T1
L1
T1
T2
L2
T2
L2
T3
L3
T3
L3
Motor
Reversing Manual Starter
3-Pole, 3-Phase
L1
Pilot Lights
(if used)
2-SPEED
2-WINDING
SINGLE PHASE
MOTOR
Motor
LOW
HIGH
T12
T13
T1
T2
T3
T1
L1
Pilot Light
(if used)
Motor
L1
HIGH
LOW
L3
T3
REV
(R.H. UNIT)
COM
T1
L1
FWD
(L.H. UNIT)
HIGH
T1
L2
REV
T11
L1
FWD
AC 2-Speed Manual Motor Starting Switches
2-Pole, 1-Phase with
Pilot Lights
2-SPEED
2-WINDING WYE CONNECTED
3- PHASE
MOTOR
3-Pole, 3-Phase
3-Pole Reversing Switches
THREE PHASE MOTOR
LINE AND
MOTOR LEADS
Line
Meter
L1 to
L2 to
L3 to
T1 to
T2 to
T3 to
L.H.
UNIT
_
_
_
T1
T2
T3
_
_
Pilot Light
Leads to
T1 T2 T3
R.H.
UNIT
L1
L2
L3
_
_
_
T1
T3
SINGLE PHASE CAPACITOR
OR SPLIT PHASE MOTOR
L.H.
UNIT
LINE AND
MOTOR LEADS
Line
L1 to
L2 to
_
_
Meter
T1 to
T4 to
T5 to
T8 to
T1
T3
L1
T2
Furnish Jumper
L1
L2
_
_
_
_
L3 to
_
_
Pilot Light
Leads to
T8 T4
Motor
R.H.
UNIT
T2
T1
T3
T1 T5
SINGLE PHASE 4-LEAD
REPULSION - INDUCTION MOTOR
L.H.
UNIT
LINE AND
MOTOR LEADS
Line
L1 to
L2 to
_
_
Meter
T1 to
T4 to
T5 to
T8 to
T2
L3
T3
T1
Furnish Jumper
L3 to
_
_
Pilot Light
Leads to
T8
T1
R.H.
UNIT
L1
L2
_
_
_
_
T2
L1
T2
T5 T4
RUN
START
8/130
Siemens Industry, Inc.
Industrial Controls Catalog
Heavy Duty Motor Starters
Class 14
Wiring Diagrams
3-Phase and Single Phase Magnetic Starters
Single Phase Magnetic Starter, Size 00–1 햲햳
Three Phase Magnetic Starter, Size 00–4
TO SUPPLY
L2
L3
L1
TO PILOT
CONTROL DEVICE
IF PROVIDED
3
CONTROL FUSES
(OPTIONAL)
1
V
M
B
W
1
T1
T2
ESP200
95 96
A3+ A4-
XF
T3
C
97 98
3
W
M
96
1
XF
A1 ESP200 A3
95 96
97 98
A3+ A4-
C
SEC
H3
T1
MAY BE
GROUNDED BY
CUSTOMER
X1
H2
SEC
H1
T2
MOTOR
X2
MAY BE
GROUNDED BY
CUSTOMER
Solid State Overload 3-Phase Sizes 5-8
Three Phase Magnetic Starter with DC Coil, Sizes 00–4
TO PILOT
CONTROL DEVICE
SEC FUSE
H4
H3
X2
H1
MOTOR
CONTROL
TRANSFORMER
(OPTIONAL)
B
T2
T1
2
X1
H2
V
A
SEC FUSE
H4
CONTROL FUSES
(OPTIONAL)
1
CONTROL
TRANSFORMER
(OPTIONAL)
96
A
2
TO SUPPLY
L1
L2
IF PROVIDED
INCOMING LINE
POWER WIRING:
USE 75°C COPPER WIRE ONLY.
TO SUPPLY
L1
L2
L3
SIZE
CT RATIO
5
300:5
6
600:5
7
750:5
8
1200:5
A
B
C
CIRCUIT
PROTECTIVE
DEVICE
(IF USED)
CONTROL FUSES
(OPTIONAL)
1
IF PROVIDED
3
2
V
M
T1
B
W
T2
T3
LATE
BREAK
CONTACT
1
96 CONTROL
TRANSFORMER
(OPTIONAL)
XF
C
ESP200
95 96
97 98
A3+ A4-
H2
H3
X1
NOTE A
"A"
L1/1
SEC FUSE
H4
X1
2CT
3
L2
A1
L3
"C "
A2
REMOVE WIRE " C " IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.
CONTACTOR
M
2
SEC
X2
"B "
CURRENT
TRANSFORMER
H1
(WHEN USED, SEE TABLE)
RELAY
1CT
MAY BE
GROUNDED BY
CUSTOMER
MOTOR
2CT
X1
3CT
X1
(IF USED)
X1
95
O.L.
96
T1
T2
T3
NOTES:
A: 2CT IS LOCATED ON THE LINE SIDE
OF CONTACTOR ON SIZE 7 STARTERS ONLY.
Ambient Compensated
Single Phase Sizes 00-2 1/2
햲 Warning:
The ESP200 Starter and Single Phase Motor
must be wired as shown above. For L1, L2 do not use
the middle terminal or hole.
Siemens Industry, Inc.
Industrial Controls Catalog
Ambient Compensated
3-Phase Sizes 00-2 1/2
LOAD
Ambient Compensated
3-Phase Sizes 3-4
햳 Full
Load Amps (FLA): Adjustment of the ESP200 solid
state overload relay accommodates the single phase
motor.
8/131
Combination Heavy Duty Starters
Class 17, 18
Wiring Diagrams
3-Phase
Size 00–4
TO PILOT
CONTROL DEVICE
IF PROVIDED
3
TO SUPPLY
L1
L2
L3
CONTROL FUSES
(OPTIONAL)
1
V
M
B
W
1
CONTROL
TRANSFORMER
(OPTIONAL)
96
A
2
T1
95 96
T2
ESP200
A3+ A4-
XF
T3
C
97 98
SEC FUSE
H4
H2
H3
X1
SEC
X2
H1
MOTOR
MAY BE
GROUNDED BY
CUSTOMER
Size 5–8
SIZE
CT RATIO
5
300:5
6
600:5
7
750:5
8
1200:5
"C"
Remove
wire “C” if control transformer is used. For
separate control voltage source, remove jumpers
“A” and “B” and connect source to control fuse line
terminals.
8/132
Remove
wire “C” if the contactor coil is to operate
on a voltage other than line voltage or in a separate
control source.
Siemens Industry, Inc.
Industrial Controls Catalog
Reversing Heavy Duty Starters
Class 22
Wiring Diagrams
3-Phase Ambient Compensated Overload
Bimetal Overload
Sizes 0-1 3/4
Bimetal Overload
Sizes 2-2 1/2
Bimetal Overload
Sizes 3-4
Single Phase Ambient Compensated Overload
3-Wire, 2-Pole Sizes 0-1 3/4
Siemens Industry, Inc.
Industrial Controls Catalog
8/133
Reversing Heavy Duty Starters
Class 22
Wiring Diagrams
3-Phase Solid State Overload
3-Phase Reversing Magnetic Starter
Sizes 00–13⁄4
3-Phase Reversing Magnetic Starter
Sizes 2–4
TO SUPPLY
TO SUPPLY
L3
L1 L2
3
7
W
FOR
6
V REV W
CONTROL FUSES
(OPTIONAL)
2
CONTROL
TRANSFORMER
(OPTIONAL)
96
1
4
ESP200
A
95 96
97 98
A3+ A4-
C
T3
T2
T1
XF
B
V
SEC FUSE
H4
2
7
4
6
96 CONTROL
TRANSFORMER
(OPTIONAL)
1
W
REV
XF
C
T3
T2
T1
1
V
X2
H1
ESP200
95 96
97 98
A3+ A4-
B
A
MAY BE
GROUNDED BY
CUSTOMER
X2
H1
T1 MOTOR T3
X1
SEC
H3
SEC
H3
SEC FUSE
H4
H2
X1
H2
T2
W
FOR
CONTROL FUSES
(OPTIONAL)
5
3
1
5
V
L3
L2
L1
MOTOR
MAY BE
GROUNDED BY
CUSTOMER
Solid State Overload
Sizes 5–6
TO SUPPLY
L1
L2
L3
"REV"
CONTACTOR
"FWD"
"FWD"
CONTACTOR
CONTRACTOR
MECHANICAL
INTERLOCK
O.L.
RELAY
CURRENT
TRANSFORMER
(SEE TABLE)
REMOVE WIRE "C" IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.
MOTOR
3-Phase Reversing Magnetic Starter
with DC Coil, Sizes 00–13⁄4
3-Phase Reversing Magnetic Starter
with DC Coil, Sizes 2–4
L1
1
7
3
V
FOR
5
W
V
REV
T3
T2
T1
ESP200
LATE BREAK
6
B
T2
T1
MOTOR
96 CONTROL
TRANSFORMER
(OPTIONAL)
SEC FUSE
XF
H4
X1
C
H2
H3
T3
3 PHASE REVERSING
SEC
V
W
FOR
V
2
7
L.B.
T1
T2
4
6
XF
T3
X2
T2
T1
MOTOR
1
T3
W
L.B.
ESP200
H1
MAY BE
GROUNDED BY
CUSTOMER
REV
95 96
97 98
A3+ A4-
96
C
SEC FUSE
H4
H2
H3
CONTROL FUSES
(OPTIONAL)
B
8/134
NEMA 2 - 4
L3
5
CONTROL FUSES
(OPTIONAL)
4
95 96
97 98
A3+ A4-
L2
3
W
1
2
WIRING DIAGRAM
TO SUPPLY
TO SUPPLY
L2
L3
L1
X1
CONTROL
TRANSFORMER
SEC (OPTIONAL)
X2
H1
MAY BE
GROUNDED BY
CUSTOMER
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Reversing Heavy Duty Starters
Class 25, 26
Wiring Diagrams
3-Phase
3-Phase Reversing Magnetic Starter
Sizes 00–13⁄4
3-Phase Reversing Magnetic Starter
Sizes 2–4
TO SUPPLY
L3
L1 L2
TO SUPPLY
3
FOR
7
W
6
V REV W
CONTROL FUSES
(OPTIONAL)
2
CONTROL
TRANSFORMER
(OPTIONAL)
96
1
4
ESP200
95 96
97 98
A3+ A4-
T1
T2
A
XF
B
C
T3
H2
FOR
T1
SEC FUSE
H4
H3
T2
V
W
T2
1
V
2
7
4
6
REV
96 CONTROL
TRANSFORMER
(OPTIONAL)
1
W
XF
C
T3
SEC FUSE
H4
H2
H3
X1
X1
SEC
X2
H1
ESP200
SEC
95 96
97 98
A3+ A4-
A
X2
H1
T1 MOTOR T3
CONTROL FUSES
(OPTIONAL)
5
3
1
5
V
L3
L2
L1
B
MAY BE
GROUNDED BY
CUSTOMER
MOTOR
MAY BE
GROUNDED BY
CUSTOMER
3 PHASE REVERSING
TO SUPPLY
L1
L2
Size 5–6
L3
"REV"
CONTACTOR
"FWD"
"FWD"
CONTACTOR
CONTRACTOR
MECHANICAL
INTERLOCK
O.L.
RELAY
CURRENT
TRANSFORMER
(SEE TABLE)
REMOVE WIRE "C" IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.
MOTOR
Siemens Industry, Inc.
Industrial Controls Catalog
8/135
Two Speed Heavy Duty Starters
Class 30 & 32 Non-Combination and Combination Starters
Wiring Diagrams
1 Winding Constant Horsepower Size 0–13/4
ELEMENTARY DIAGRAM
TO SUPPLY
L1
L2
DISCONNECT or
CIRCUIT BREAKER
HIGH
LOW
HIGH
LOW
T4
T2
LOW
T3
2
T5
1
96
CONTROL
TRANSFORMER
(OPTIONAL)
T6
T2
CONSTANT HORSEPOWER
MOTOR
3
6 LOW
5
7 HIGH
HIGH
4
B
7
2
ESP200
97 98
95 96
LOW
HIGH
8
T1
T2
XF
ESP200
97 98
95 96
A
A3+ A4-
95
CONTROL FUSES
(OPTIONAL)
1
V HIGH W
6
ALL OL'S
96
8
4
T1
T3
T1
OL
LOW LOW
3
V LOW W
T4
T5
LOW
A
5
T6
OL
HIGH HIGH
NEMA 00 - 1 3
WIRING DIAGRAM
TO SUPPLY
L1 L2 L3
L3
C
A3+ A4-
T3
T6
T4
SEC FUSE
H4
X1
H2
SEC
T5
H3
X2
H1
LOW
T1
T2
T3
T4
T5
T6
POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3 T4 T5 T6
HIGH SPEED T6 T4 T5
MAY BE
GROUNDED BY
CUSTOMER
MOTOR
1 Winding Constant Horsepower Size 2–4
5
1
V LOW W
A
2
B
1
96
CONTROL
TRANSFORMER
(OPTIONAL)
T6
T4
T5
XF
ESP200
95 96
97 98
A3+ A4-
T2
V L W
7
ESP200
95 96
97 98
CONTROL FUSES
(OPTIONAL)
3
6
VHIGHW
4
6
T1
NEMA 2 - 4
WIRING DIAGRAM
TO SUPPLY
L1 L2 L3
C
A3+ A4-
SEC FUSE
H4
X1
H2
SEC
T3
H3
X2
H1
T1
T2
T3
T4
T5
T6
MAY BE
GROUNDED BY
CUSTOMER
MOTOR
1 Winding Constant or Variable Torque Size 0–13/4
ELEMENTARY DIAGRAM
TO SUPPLY
L1
L2
L1
DISCONNECT or
CIRCUIT BREAKER
LOW
HIGH
LOW
HIGH
T2
T3
HIGH
T6
OL
HIGH HIGH
T4
HIGH
T5
ALL OL'S
96
L2
NEMA 0
L3
T4
T1
OL
LOW LOW
A
WIRING DIAGRAM
TO SUPPLY
L3
95
5
T3
T2
T5
T6
CONSTANT TORQUE MOTOR
T4
T3
2
LOW
5 LOW 7
4
HIGH
POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3
HIGH SPEED T6 T4 T5 T1 T2 T3
V HIGH W
CONTROL FUSES
(OPTIONAL)
1
V LOW W
4
6
B
7
T1
1
96
CONTROL
TRANSFORMER
(OPTIONAL)
2
T2
T5
T6
VARIABLE TORQUE MOTOR
3 HIGH 6
3
8
T1
LOW
8
ESP200
97 98
95 96
A
A3+ A4-
T6
T4
ESP200
97 98
95 96
A3+ A4-
T5
T1
T2
T3
XF
C
SEC FUSE
H4
X1
H2
SEC
H3
X2
H1
HIGH
T1
T2
T3
T4
T5
T6
MOTOR
MAY BE
GROUNDED BY
CUSTOMER
Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used.
8/136
Siemens Industry, Inc.
Industrial Controls Catalog
Two Speed Heavy Duty Starters
Class 30 & 32 Non-Combination and Combination Starters
Wiring Diagrams
1 Winding Constant or Variable Torque Size 2–4
TO SUPPLY
L1 L2 L3
DISCONNECT or
CIRCUIT BREAKER
LOW
T4
H
OL
LOW LOW
T1
T3
T2
H
LOW
T3
T4
HIGH
3 HIGH H
2
6
LOW
5 LOW 7
4
V LOW W
6
4
T2
T5
T6
VARIABLE TORQUE MOTOR
T5
HIGH
LOW
CONTROL FUSES
(OPTIONAL)
3
1
V HIGHW
T1
T3
ALL OL'S
95
5
T4
T6
OL
HIGH HIGH
96
T1
T2
T5
T6
CONSTANT TORQUE MOTOR
H
HIGH
A
NEMA 2 - 4
WIRING DIAGRAM
ELEMENTARY DIAGRAM
TO SUPPLY
L1 L2 L3
7
ESP200
95 96
97 98
A3+ A4-
A3+ A4-
T6
H
T1
ESP200
95 96
97 98
T4
1
96
CONTROL
TRANSFORMER
(OPTIONAL)
A
8
B
V H W
2
T2
T3
SEC FUSE
XF
C
H4
X1
H2
SEC
T5
H3
H
HIGH
X2
H1
POSITION L1 L2 L3 TOGETHER
LOW SPEED T1 T2 T3
HIGH SPEED T6 T4 T5 T1 T2 T3
T1
T2
T3
T4
T5
T6
MAY BE
GROUNDED BY
CUSTOMER
MOTOR
D68784002
2 Winding Constant Horsepower & 2 Winding Constant or Variable Torque Size 0–4
TO SUPPLY
L1 L2 L3
L2
L3
DISCONNECT or
CIRCUIT BREAKER
LOW
HIGH
A
T3
V HI
2
T13
7
B
6
1
CONTROL
TRANSFORMER
(OPTIONAL)
96
T12
XF
T11
T13
TWO WINDING MOTOR
ESP200
95 96
97 98
A
A3+ A4-
95
W
4
T12
ALL OL'S
POSITION L1 L2 L3
LOW SPEED T1 T2 T3
HIGH SPEED T11 T12 T13
V LO W
T1
T11
OL
HIGH
HIGH
96
8
T2
T3
CONTROL FUSES
(OPTIONAL)
1
T1
OL
LOW
LOW
HIGH
5
3
T2
LOW
NEMA 2 - 4
WIRING DIAGRAM
TO SUPPLY
L1
ELEMENTARY DIAGRAM
5 LOW 6
4
HIGH
3 HIGH 7
2
LOW
HIGH
ESP200
95 96
97 98
A3+ A4-
C
SEC FUSE
H4
SEC
8
T1
T2
T3
T11
T12
X1
H2
T13
H3
X2
H1
LOW
T1
T2
T3
T11
T12
T13
MOTOR
MAY BE
GROUNDED BY
CUSTOMER
D68786001
Note: For separate control voltage source, remove jumpers “A” and “B” and connect source to control fuse terminal. Remove jumper “C” if control transformer is used.
Siemens Industry, Inc.
Industrial Controls Catalog
8/137
Reduced Voltage Starters & Pump Panels
Class 36, 37, 88
Wiring Diagrams
Part Winding
EMT
8/138
Siemens Industry, Inc.
Industrial Controls Catalog
Reduced Voltage Starters & Pump Panels
Class 36, 37, 88
Wiring Diagrams
Auto Transformer
TO SUPPLY
L1 L2 L3
SEK
SES
SAW
LMB
SEK
SES
SAW
LMB
SEK
SES
SAW
LMB
OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER
OL
1S
3L1
0%
50%
1L1
R
65%
1CT
80%
2S
L2 L3
100%
L1
T1
2L1
OL
0%
50%
65%
80%
R
1S
3L2
1L2
100%
2S
2CT
*
T2
2L2
FOR MOTOR
HP SEE
CONTROLLER
NAMEPLATE
MOTOR
OL
4FU
71
MR
73
1S
0%
50%
65%
3L3
80%
R
FOR STARTER
SIZES 1-4, 1CT-3CT
ARE NOT USED.
L1
1L3
100%
2S
3CT
T3
2L3
1S
74
(A1)
R
75
(A2)
2S
76
MR
5FU
72
L2
2S
CR1
77
(A1)
(A2)
1S
*
CR1
L1
79
H1
MECH
INTLK
(A1)
(A2)
R
H4
3FU
L2
CPT
X2
X1
CONNECT
VOLTAGE
AS SPECIFIED
PER NAMEPLATE
NOTE E
2
3
2
LMB
SAW
SES
SEK
1
X2
TR
SUPPLIED AS REQUIRED
3
LMB
SAW
SES
SEK
JUMPER
1FU
12
TAS
1
2FU
78
1S
(A1)
(A2)
MR
4
(95)
OL
(96)
3
MR
TR
6
(A1)
(A2)
CR1
NOTC
CONNECTIONS FOR OPTIONAL DEVICES
Note E:
Remove jumper if thermal
protection switch is provided.
HAND
*
2
3
1PB
OFF
AUTO
(A2)
(A1)
CR2
(A2)
3
2PB
5
1SS
HAND
AUTO
CONTACT
*
3
4
ETM
OFF
AUTO
1
RUN/ON/
RUNNING
3
4
3
5
1
(A1)
2PB
START
2
1
1
*
SURGE SUPPRESSOR
START
STOP
1
1SS
*
OFF
1LT
AUTO
CONTACT
OL
OL TRIPPED
9
X2
MR
OFF/STOP
X2
10
1
4LT
ON
1
1SS
*
3
1
5LT
OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS
Siemens Industry, Inc.
Industrial Controls Catalog
8/139
Reduced Voltage Starters & Pump Panels
Class 36, 37, 88
Wiring Diagrams
Wye Delta (Open Transition)
TO SUPPLY
L1 L2 L3
OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER
OL
1L1
1M
T1
2M
T6
1M
T2
T1
1CT
T6
OL
1L2
T1
T6
T2
S
2CT
S
S
2M
T3
T4
T4
S
T5
1M
1L3
T4
T5
OL
T2
T3
T3
3CT
2M
T5
FOR STARTER
SIZES 1-4, 1CT-3CT
ARE NOT USED.
1L1
1L2
4FU
50
MR
2M
51
CR1
52
53
(A1)
54
(A2)
MR
55
S
S
S
56
57
*
5FU
MECH
(A1)
(A2)
INTERLOCK
2M
1M
(A1)
(A2)
1M
SUPPLIED AS REQUIRED
3FU
2FU
H1
1FU
1
H3 H2
H4
CPT
1X1
X1
X2
CONNECT
VOLTAGE
AS SPECIFIED
PER NAMEPLATE
X2
TR
1
3
2
2
MR
(A1)
TR
3
OL
4
(A2)
MR
(A1)
6
X2
(96)
(95)
(A2)
CR1
NCTO
CONNECTIONS FOR OPTIONAL DEVICES
2
3
CR2
(A2)
3
2PB
5
1
1SS
HAND
*
(A2)
(A1)
START
2
1
(A1)
2PB
1PB
OFF
HAND
AUTO
*
SURGE SUPPRESSOR
START
STOP
1
AUTO
CONTACT
*
3
4
ETM
OFF
AUTO
1
RUN/ON/
RUNNING
3
3
4
1LT
AUTO
5 CONTACT
1
1SS
*
OL
OL TRIPPED
9
X2
MR
OFF/STOP
10
X2
1
4LT
ON
OFF
1
1SS
*
3
1
5LT
OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS
8/140
Siemens Industry, Inc.
Industrial Controls Catalog
Reduced Voltage Starters & Pump Panels
Class 36, 37, 88
Wiring Diagrams
Wye Delta (Closed Transition)
TO SUPPLY
L1 L2 L3
OPTIONAL
DISCONNECT
OR
CIRCUIT BREAKER
OL
1M
T1
T1
1CT
1L1
3L1
RES A
1A
2M
T6
OL
1M
1L2
3L2
2CT
RES B
T1
T6
T2
T2
S
1A
S
S
2M
T3
T4
S
T5
1M
1L3
T4
T5
OL
T3
T3
3CT
3L3
RES C
2M
T2
1A
FOR STARTER
SIZES 1-4, 1CT-3CT
ARE NOT USED.
1L2
1L1
4FU
50
MR
2M
51
CR1
52
53
(A1)
(A2)
MR
54
55
5FU
1A
1A
S
S
57
56
(A1)
58
(A1)
(A2)
S
*
MECH
(A2)
INTERLOCK
2M
1M
(A1)
(A2)
1M
SUPPLIED AS REQUIRED
3FU
2FU
H1
1FU
1
H3 H2
H4
CPT
1X1
X1
X2
TR
6
CONNECT
VOLTAGE
AS SPECIFIED
PER NAMEPLATE
X2
(A1)
(A2)
CR1
NCTO
TR
1
3
2
2
MR
(A1)
MR
4
(A2)
OL
(96)
(95)
X2
3
CONNECTIONS FOR OPTIONAL DEVICES
2
3
1PB
OFF
HAND
AUTO
*
(A2)
START
(A1)
CR2
(A2)
3
2PB
5
1SS
HAND
AUTO
CONTACT
*
3
4
ETM
OFF
AUTO
1
RUN/ON/
RUNNING
3
3
5
1
(A1)
2PB
2
1
1
*
SURGE SUPPRESSOR
START
STOP
1
1SS
*
OFF
4
1LT
AUTO
CONTACT
OL
OL TRIPPED
9
X2
MR
OFF/STOP
10
X2
1
4LT
ON
1
1SS
*
3
1
5LT
OPTIONAL DEVICES ARE FURNISHED PER CONTRACT DOCUMENTS
Siemens Industry, Inc.
Industrial Controls Catalog
8/141
Heavy Duty Contactors and Reversing Contactors
Class 40, 43
Wiring Diagrams
3-Phase Magnetic Contactors and Reversing Contactors
3-Phase Contactors—Size 00–4
3-Phase Reversing Contactors—Size 00–4
3-Phase Contactors—Size 5, 6
3-Phase Reversing Contactors—Size 5, 6
TO SUPPLY
L1
L2
L3
"REV"
CONTACTOR
"FWD"
"FWD"
CONTACTOR
CONTRACTOR
MECHANICAL
INTERLOCK
RELAY
CURRENT
TRANSFORMER
REMOVE WIRE "C" IF THE CONTACTOR
COIL IS TO OPERATE ON A VOLTAGE
OTHER THAN LINE VOLTAGE OR ON A
SEPARATE CONTROL SOURCE.
LOAD
Single Phase Magnetic Contactors and Reversing Contactors
Single Phase Contactors—Size 00–4
8/142
Single Phase Reversing Contactors—Size 00–1P
Siemens Industry, Inc.
Industrial Controls Catalog
Duplex Heavy Duty Controllers
Class 83, 84
Wiring Diagrams
Standard Duplex Pump Panel (92)
Siemens Industry, Inc.
Industrial Controls Catalog
Duplex Panel w/o alternator (95)
8/143
Duplex Heavy Duty Controllers
Class 83, 84
Wiring Diagrams
Duplex Panel with Relay Alternation (93)
8/144
Duplex Panel with Lead Pump Transfer Switch (94)
Siemens Industry, Inc.
Industrial Controls Catalog
Standard & Irrigation Pump Panels
Class 81, 87
Wiring Diagrams
Standard Class 87 Pump Panel
Irrigation Class 81 Pump Panel
Siemens Industry, Inc.
Industrial Controls Catalog
8/145
Lighting and Heating Contactors
Electrically Held, Class LE
Wiring Diagrams
20 AMP
30 – 100 AMP
200 – 400 AMP
8/146
Siemens Industry, Inc.
Industrial Controls Catalog
Lighting and Heating Contactors
Mechanically Latched 20 Amp, Class CLM
Wiring Diagrams
ON
OFF
CONTACTOR CONTROL
VOLTAGE
L
OFF
L
ON
C
0
COMMON OR SEPARATE
CONTROL LINES
5
ON
OFF
CONTROL
MODULE
VOLTAGE
OFF
2
CR1
3
CR2
L
CR2
CR1
0
CR1
CR2
C
4
TYPICAL OFF-ON
SELECTOR SWITCH
ON
COIL
PILOT LIGHTS
REQUIRE (1) EA.
CLM4097291
AUXILIARY
CONTACT KIT.
3 WIRE CONTROL ACC. 48
ON
CONTACTOR CONTROL
VOLTAGE
HAND
OFF
AUTO
OFF
5
CONTROL
MODULE
VOLTAGE
CR
CR
4
0
C
OFF
5
CR2
2
CONTROL
MODULE
VOLTAGE
COIL
REMOTE
CONTROL
3
OFF
L
CR
3
L
CONTACTOR CONTROL
VOLTAGE
L
CR1
CR2
L
CR1
0
CR1
C
4
COIL
ON
ON
ON-OFF (FORM 3) CONTROL ACC. 49
2 WIRE CONTROL ACC. 47
CONNECTIONS TO CONTROL MODULES
CONTACTOR CONTROL
VOLTAGE
OFF
5
L
ON-OFF
CONTROL
MODULE
VOLTAGE
3
CR
4
CR
0
CR
C
COIL
ON
2 WIRE CONTROL ACC. 47
Siemens Industry, Inc.
Industrial Controls Catalog
MODULE
TERMINAL
L
1
2
CONNECT TO:
NOT USED
CONT. STATION FOR ACC. 48 & 49
3
CONT. STATION FOR ACC. 47,48 & 49
4
MODULE CONTROL VOLTAGE *
5
CONTACTOR CONTROL VOLTAGE
O
" CONTACTOR
"
TERMINAL O ON
C
" CONTACTOR
"
TERMINAL C ON
* FOR 24 VDC CONTROL MODULES
CONNECT TERMINAL 4 TO NEGATIVE (-)
8/147
Lighting and Heating Contactors
Mechanically Latched 30–40 Amps, Class CLM
Wiring Diagrams
Mechanically Latched, CLM 30–200 Amps
Connection Diagram for Common/Separate
Control with Momentary Pushbutton or
ON-OFF Selector Switch CLMOC, CLMOD,
CLMOE, and CLMOF
Connection for 2-Wire Control CLMOC,
CLMOD, CLMOE, and CLMOF
Connection for Hand/Off/Auto Control
CLMOC, CLMOD, CLMOE, and CLMOF
Mechanically Latched Type CLM 300 and 400 Amp
Connection Diagram for Common/Separate
Control with Momentary Pushbutton or
ON-OFF Selector Switch CLMOG and
CLMOH
Connection for 2-Wire Control CLMOG and
CLMOH
Connection for Hand/Off/Auto Control
CLMOG and CLMOH
Control
relay is required for 2-wire and Hand/Off/Auto
Control, as shown in diagram.
8/148
Siemens Industry, Inc.
Industrial Controls Catalog
Industrial Control Power Transformers
Class MT, MTG
Wiring Diagrams
Voltage Letter
A햲햴
Voltage Letter
B햳 햴
Voltage Letter
C햳 햴
When secondary fuse clips are installed,
Terminal X1 becomes XF
When secondary fuse clips are installed,
Terminal X1 becomes XF
Voltage Letter
D햳
Voltage Letter
E햲 햴
When secondary fuse clips are installed,
Terminal X1 becomes XF
When secondary fuse clips are installed,
Terminal X1 becomes XF
Voltage Letter
G햲
Voltage Letter
H
Voltage Letter
I
When secondary fuse clips are installed,
Terminal X1 becomes XF
Does not include secondary fuse clips
Does not include secondary fuse
clips
Voltage Letter
J 햳햴
Voltage Letter
L
Voltage Letter
M햲
When secondary fuse clips are installed,
Terminal X3 becomes XF
Does not include secondary fuse clips
When secondary fuse clips are
installed, Terminal X1 becomes XF
Voltage Letter
F햲
When secondary fuse clips are
installed, Terminal X1 becomes XF
When secondary fuse clips are
installed, Terminal X1 becomes XF
Voltage Letter
P
H1
햲
햳
햴
Includes secondary fuse clips on sizes 50-750VA
Includes secondary fuse clips on sizes 50-500VA
Secondary fuse clips are not included on MTG
transformers.
Siemens Industry, Inc.
Industrial Controls Catalog
X2
380V
24V
H2
X1
Does not include secondary fuse clips
8/149
Overload Relay Heater Tables
Selection of Heater Elements for Overload Relays
General
Use only when motor full load
current is not known. Motor amps
will vary depending on the type and
manufacturer of the motor. These
average values, for motors with service
factor of 1.15, are to be used only as a
guide. The formulas at the bottom of the
page may be used to obtain approximate
amps for other motors.
Note: RPM shown for 60 cycle motors.
For 50 cycle motors, multiply RPM by .83.
CAUTION: Actual motor amps may be
higher or lower than the values listed
below for a particular motor. For more
reliable motor protection, select heater
elements by using the full load motor
nameplate amps.
Single Phase motor full load amps of
the same horsepower, voltage and speed
vary over wide ranges. The following
table conforms with table 430.148 of
the NEC.
3-Phase
1
⁄4
1
⁄3
1
⁄2
3
⁄4
1
11⁄2
2
3
5
71⁄2
10
15
20
50 Hz
Syn
Speed
RPM
200
Volts
230
Volts
460
Volts
575
Volts
1800
1200
900
1800
1200
900
1800
1200
900
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
1.09
1.61
1.84
1.37
1.83
2.07
1.98
2.47
2.74
2.83
3.36
3.75
3.22
4.09
4.32
4.95
5.01
5.59
6.07
6.44
6.44
7.36
7.87
9.09
9.59
10.8
11.7
13.1
15.5
16.6
18.2
18.3
22.4
24.7
25.1
26.5
29.2
30.8
32.2
35.1
41.9
45.1
47.6
51.2
58.0
58.9
60.7
63.1
0.95
1.40
1.60
1.19
1.59
1.80
1.72
2.15
2.38
2.46
2.82
3.26
2.80
3.56
3.76
4.30
4.36
4.86
5.28
5.60
5.60
6.40
6.84
7.90
8.34
9.40
10.2
11.4
13.5
14.4
15.8
15.9
19.5
21.5
21.8
23.0
25.4
25.8
28.0
30.5
36.4
39.2
41.4
44.5
50.4
51.2
52.8
54.9
0.48
0.70
0.80
0.60
0.80
0.90
0.86
1.08
1.19
1.23
1.46
1.63
1.40
1.78
1.88
2.15
2.18
2.43
2.64
2.80
2.80
3.20
3.42
3.95
4.17
4.70
5.12
5.70
5.76
7.21
7.91
7.92
9.79
10.7
10.9
11.5
12.7
13.4
14.0
15.2
18.2
19.6
20.7
22.2
25.2
25.6
26.4
27.4
0.38
0.56
0.64
0.48
0.64
0.72
0.69
0.86
0.95
0.98
1.17
1.30
1.12
1.42
1.50
1.72
1.74
1.94
2.11
2.24
2.24
2.56
2.74
3.16
3.34
3.76
4.10
4.55
5.41
5.78
6.32
6.33
7.81
8.55
8.70
9.19
10.1
10.7
11.2
12.2
14.5
15.7
16.5
17.8
20.1
20.5
21.1
21.9
Formula—Approximate Full Load Amps
for Other Motors
208 Volt Full Load Amp 앒 230 Volt current ҂ 110%
2-Phase FLA 앒 0.866 ҂ the 3-Phase FLA
2-Phase, 3-wire current in common wire 앒 1.41 ҂ that in
the other 2 lines
8/150
Full Load Current (60Hz)
Hp
1
⁄8
1
⁄4
1
⁄3
1
⁄2
3
⁄4
1
1 1⁄2
2
3
5
7 1⁄2
10
115 Volts
230 Volts
4.4
5.8
7.2
9.8
13.8
16
20
24
34
56
80
100
2.2
2.9
3.6
4.9
6.9
8
10
12
17
28
40
50
3-Phase
Full Load Current (60Hz)
Hp
1-Phase
380
Volts
0.55
0.81
0.93
0.64
0.92
1.04
0.99
1.24
1.38
1.42
—
1.88
1.70
2.06
2.28
2.60
2.69
2.94
3.20
3.39
3.39
3.84
4.14
4.77
5.02
5.70
6.20
6.80
8.20
8.74
9.59
9.60
11.50
13.00
13.20
13.90
15.40
16.30
16.90
18.50
22.00
23.70
25.00
26.90
30.50
31.00
31.90
33.20
Full Load Current (60Hz)
Hp
25
30
40
50
60
75
100
125
150
200
250
300
400
50 Hz
Syn
Speed
RPM
200
Volts
230
Volts
460
Volts
575
Volts
380
Volts
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
3600
1800
1200
900
1800
1200
1800
69.9
74.5
75.4
77.4
84.8
86.9
90.6
94.1
111
116
117
121
138
143
145
150
164
171
173
177
206
210
212
222
266
271
275
290
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
60.8
64.8
65.6
67.3
73.7
75.6
78.8
81.8
96.4
101
102
105
120
124
126
130
143
149
150
154
179
183
184
193
231
236
239
252
292
293
298
305
343
348
350
365
458
452
460
482
559
568
573
600
278
684
896
30.4
32.4
32.8
33.7
36.8
37.8
39.4
40.9
48.2
50.4
50.6
52.2
60.1
62.2
63.0
65.0
71.7
74.5
75.0
77.0
89.6
91.6
92.0
96.5
115
118
120
126
146
147
149
153
171
174
174
183
229
226
230
241
279
284
287
300
339
342
448
24.3
25.9
26.2
27.0
29.4
30.2
31.5
32.7
38.5
40.3
40.4
41.7
48.2
49.7
50.4
52.0
57.3
59.4
60.0
61.5
71.7
73.2
73.5
77.5
92.2
94.8
95.6
101
116
117
119
122
137
139
139
146
184
181
184
193
223
227
229
240
271
274
358
36.80
39.20
39.60
40.70
—
45.70
47.60
49.50
—
61.00
61.20
63.20
—
75.20
76.20
78.50
—
90.00
91.10
93.10
—
111.00
112.00
117.00
—
144.00
145.00
153.00
—
177.00
180.00
186.00
—
210.00
210.00
211.00
—
274.00
276.00
279.00
—
343.00
345.00
347.00
392.00
395.00
—
25Hz 1500 RPM, amps 앒 amps of 60Hz, 3600 RPM
25Hz 750 RPM, amps 앒 amps of 60Hz, 1800 RPM
Service factor 1.0 앒 amps ҂ 0.9
50°C–55°C motor 앒 amps ҂ 0.9
Siemens Industry, Inc.
Industrial Controls Catalog
Overload Relay Heater Tables
Selection of Heater Elements for Overload Relays
General
To Select Heater Catalog Number Use
2. Refer to the specified table and use
▪
▪
▪
▪
the controller size and motor amps to
select the heater catalog number.
a. If motor amps are not known, an
approximate value may be found on
the previous page. These values
should be used with caution and only
when motor amps are not available.
Heaters shown on the following pages
provide a maximum trip rating of 125%
of minimum motor amperes for 40˚C
motors (service factor 1.15). For other
motors (service factor 1.0), select the
next lower listed heater catalog number
within the designated table which
provides a maximum trip rating of
approximately 115%.
Product Class
Controller Size
Motor Amp
Phase
Catalog No 14 C P 3 2 B C 81
Phase
Size
Class
1. Find heater table number below,
using the Product Class, Controller
Size and Phase. Heater table number
is found in the column under the type
of overload and phase.
Overload relays do not provide
protection against short circuits.
To ensure proper coordination with
short circuit protective device, select
heaters from the information packaged
with the control device.
Heater Table Number
Size
or
Amperage
Controller
Size
Letter
Bimetal Standard Trip (Class 20)
Bimetal Quick Trip (Class 10)
Compensated
E Heaters
Green Reset
Compensated
K Heaters
Green Reset
Class
Description
SMF
Manual
All
—
14, 22
Magnetic
Non-reversing,
Reversing
00-4
B–J
213
233
313
332
0-4
C-J
—
233
—
332
25-180A
D–J
216
238
316
335
17, 18
25, 26
30, 32
83, 84
87, 89
48
Combination
Reversing Combination
Multi Speed
Pump Controllers
Motor Control Centers
Panel Mounted
Overload Relay
1Ph
3Ph
1Ph
3Ph
See Page 8/152
ESP200 starters do not require heater elements.
Overload
Relay Selection Multi-Speed
Each speed requires a separate set of overloads. The
adjustment range must be selected on the basis of the
full-load current for each particular speed.
Siemens Industry, Inc.
Industrial Controls Catalog
8/151
Manual Control
Heater Elements, Class SMF
General
Ordering Information
1. Determine number of heater elements required from Table A.
2. Determine motor full load current and service factor.
NOTE: If motor amps are unknown, an approximate value may be found on page 8/150. These values
should be used with caution and only when motor amps are not available.
3. If the motor and controller are in the same ambient temperature:
a. For 1.15 to 1.25 service factor motors use 100% of motor full load current for heater element selection.
b. For 1.0 service factor motors use 90% of motor full load current for heater element selection.
c. Heater elements are class 20.
Heater Elements Class SMF
4. If the motor and controller are in different ambient temperatures multiply motor full load current by the multiplier in
Table B. Use the resultant full load current for heater element selection.
5. Select proper heater element from table below.
6. All tables are based on the operation of the motor and controller in the same ambient temperature, 40°C (104°F) or
less. Always be certain the correct heater element is installed in the starter before operating the motor.
Heater
Catalog Number
Motor Full-Load
Current (Amps)
SMFH01
SMFH02
SMFH03
SMFH04
SMFH05
SMFH06
SMFH07
SMFH08
SMFH09
SMFH10
SMFH11
SMFH12
SMFH13
SMFH14
SMFH15
SMFH16
SMFH17
SMFH18
SMFH19
SMFH20
SMFH21
SMFH22
SMFH23
SMFH24
SMFH25
SMFH26
0.157–0.173
0.174–0.192
0.193–0.212
0.213–0.235
0.236–0.261
0.262–0.289
0.290–0.321
0.322–0.355
0.356–0.399
0.41–0.44
0.45–0.49
0.50–0.53
0.54–0.58
0.59–0.65
0.66–0.71
0.72–0.78
0.79–0.85
0.86–0.96
0.97–1.04
1.05–1.16
1.17–1.25
1.30–1.39
1.38–1.54
1.48–1.63
1.57–1.75
1.66–1.86
List
Price $
Table A
Number of Heater Elements
Device
SMFF*1
SMFF*2
SMFF*3
SMFF*4
SMFF*5
SMFF*6
SMFF*22
SMFF*44
SMFF*11
SMFF*22
8/152
Number of
Heater Elements
1
2
2
Heater
Catalog Number
Motor Full-Load
Current (Amps)
SMFH27
SMFH28
SMFH29
SMFH30
SMFH31
SMFH32
SMFH33
SMFH34
SMFH35
SMFH36
SMFH37
SMFH38
SMFH39
SMFH40
SMFH41
SMFH42
SMFH43
SMFH44
SMFH45
SMFH46
SMFH47
SMFH48
SMFH49
SMFH50
SMFH51
SMFH52
1.80–1.99
1.96–2.15
2.16–2.38
2.39–2.75
2.76–2.84
2.85–3.06
3.07–3.45
3.46–3.70
3.71–4.07
4.08–4.32
4.33–4.90
4.91–5.35
5.36–5.85
5.86–6.41
6.42–6.79
6.80–7.57
7.58–8.15
8.16–8.98
8.99–9.67
9.68–9.95
9.96–10.8
10.9–12.1
12.2–13.1
13.2–13.9
14.0–15.0
15.1–16.0
List
Price $
Table B—Special Applications
Heater Element Selection
Notes
Ambient Temperature of Motor
All single pole and two pole SMF
starters require only 1 Heater
Element.
Same as
Controller
Ambient
Duplex Unit. One Heater Element
per starter.
Two Speed Starter. One Heater
Element per speed.
Continuous
Duty Motor
Service Factor
1.15 to 1.25
1.0
Product Category: NEMA
Constant 10°C
(18°F) Higher
Than Controller
Ambient
Constant 10°C
(18°F) Lower
Than Controller
Ambient
Full Load Current Multiplier
1.0
0.9
0.9
0.8
1.05
0.95
Siemens Industry, Inc.
Industrial Controls Catalog
Overload Relay Heater Tables
Full Load Motor Amps, Single Phase, Trip Class 20 – Tables 213, 216
Selection
Table 213 for Class 14, 22 (1-Phase)
Full Load Amps
Siemens Industry, Inc.
Industrial Controls Catalog
Size 00, 0, 1 Size 1P
Size 2, 21⁄2
Heater
Catalog No
0.37–0.40
0.41–0.44
0.45–0.47
0.48–0.52
0.53–0.57
0.58–0.62
0.63–0.69
0.70–0.74
0.75–0.81
0.82–0.85
0.86–0.93
0.94–1.03
1.04–1.11
1.12–1.22
1.23–1.34
1.35–1.53
1.54–1.71
1.72–1.92
1.93–2.12
2.13–2.24
2.25–2.43
2.44–2.57
2.58–2.86
2.87–3.16
3.17–3.35
3.36–3.58
3.59–3.90
3.91–4.25
4.26–4.77
4.78–5.35
5.36–5.76
5.77–6.33
6.34–6.98
6.99–7.37
7.38–7.71
7.72–8.51
8.52–9.31
9.32–10.1
10.2–10.9
11.0–12.2
12.3–13.5
13.6–15.7
15.8–17.3
17.4–19.9
20.0–21.7
21.8–23.4
23.5–24.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
19.4–22.0
22.1–23.5
23.6–25.0
25.1–27.0
27.1–28.9
29.0–31.0
31.1–34.8
34.9–36.9
37.0–43.9
44.0–46.0
46.1–48.3
48.4–55.0
55.1–60.0
E3
E4
E5
E6
E7
E8
E9
E11
E12
E13
E14
E16
E17
E18
E23
E24
E26
E27
E28
E29
E31
E32
E33
E34
E36
E37
E38
E39
E41
E42
E44
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56
E57
E60
E61
E62
E65
E66
E67
E69
E70
E72
E73
E74
E76
—
0.41–0.44
0.45–0.47
0.48–0.52
0.53–0.57
0.58–0.62
0.63–0.69
0.70–0.74
0.75–0.81
0.82–0.85
0.86–0.93
0.94–1.03
1.04–1.11
1.12–1.22
1.23–1.34
1.35–1.53
1.54–1.71
1.72–1.92
1.93–2.12
2.13–2.24
2.25–2.43
2.44–2.57
2.58–2.86
2.87–3.16
3.17–3.35
3.36–3.58
3.59–3.90
3.91–4.25
4.26–4.77
4.78–5.35
5.36–5.76
5.77–6.33
6.34–6.98
6.99–7.37
7.38–7.71
7.72–8.51
8.52–9.31
9.32–10.1
10.2–10.9
11.0–12.2
12.3–13.5
13.6–15.7
15.8–17.3
17.4–19.9
20.0–21.7
21.8–23.4
23.5–23.7
23.8–25.1
25.2–27.9
28.0–32.2
32.3–34.0
—
—
—
—
Table 216 for Class 48
Full Load Amps
List Price $
Product Category: NEMA
48DA, 48GA 48HA
48JA
Heater
Catalog No
0.34–0.36
0.37–0.40
0.41–0.43
0.44–0.47
0.48–0.51
0.52–0.56
0.57–0.62
0.63–0.67
0.68–0.73
0.74–0.77
0.78–0.84
0.85–0.93
0.94–1.00
1.01–1.10
—
1.11–1.21
1.22–1.38
1.39–1.54
1.55–1.73
1.74–1.91
1.92–2.02
2.03–2.19
2.20–2.32
2.33–2.58
2.59–2.85
2.86–3.02
3.03–3.23
3.24–3.52
3.53–3.83
3.84–4.30
4.31–4.82
4.83–5.19
5.20–5.71
5.72–6.29
6.30–6.64
6.65–6.95
6.96–7.67
7.68–8.39
8.40–9.19
9.20–9.94
9.95–10.9
11.0–12.2
12.3–14.2
14.3–15.6
—
15.7–17.9
18.0–19.6
19.7–22.3
22.4–24.0
24.1–25.9
26.0–29.5
29.6–32.5
32.6–33.5
33.6–36.9
37.0–39.2
39.3–43.1
43.2–47.4
47.5–50.0
50.1–55.2
55.3–60.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
50.0–55.9
56.0–60.9
61.0–65.9
66.0–69.9
70.0–75.9
76.0–81.9
82.0–86.9
87.0–92.9
93.0–97.9
98.0–107.9
108.0–113.9
114.0–125.0
126.0–138.0
139.0–153.0
154.0–163.0
164.0–180.0
E3
E4
E5
E6
E7
E8
E9
E11
E12
E13
E14
E16
E17
E18
E19
E23
E24
E26
E27
E28
E29
E31
E32
E33
E34
E36
E37
E38
E39
E41
E42
E44
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56
E57
E59
E60
E61
E62
E65
E66
E67
E69
E70
E71
E72
E73
E74
E76
E77
E78
E79
E80
E88
E89
E91
E92
E93
E94
E96
E97
E98
E99
E101
E102
E103
E104
E106
E107
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
27.1–30.0
30.1–33.2
33.3–35.7
35.8–39.4
39.5–43.4
43.5–46.9
47.0–51.5
51.6–57.0
57.1–62.8
62.9–69.1
69.2–75.0
75.1–83.3
—
—
—
—
—
—
83.4–86.9
87.0–92.9
93.0–100.0
—
—
—
—
—
—
—
List Price $
8/153
Overload Relay Heater Tables
Full Load Motor Amps, 3-Phase, Trip Class 20 – Tables 233, 238
Selection
Table 233 for Class 14, 17, 18, 22, 25, 26, 30, 32, 83, 84, 87 (3-Phase)
Full Load Amps
Size 00, 0, 1 Size 13⁄4
Size 2, 21⁄2
Size 3, 31⁄2
Size 4
Heater
Catalog No
0.38–0.40
0.41–0.43
0.44–0.48
0.49–0.53
0.54–0.57
0.58–0.62
0.63–0.66
0.67–0.72
0.73–0.80
0.81–0.85
0.86–0.92
0.93–0.99
1.00–1.08
1.09–1.23
1.24–1.37
1.38–1.54
1.55–1.69
1.70–1.80
1.81–1.94
1.95–2.07
2.08–2.26
2.27–2.54
2.55–2.69
2.70–2.88
2.89–3.14
3.15–3.40
3.41–3.81
3.82–4.26
4.27–4.62
4.63–5.09
5.10–5.61
5.62–5.91
5.92–6.15
6.16–6.70
6.71–7.54
7.55–8.29
8.30–8.99
9.00–9.85
9.86–10.4
10.5–12.0
12.1–13.6
13.7–15.6
15.7–17.0
17.1–18.4
18.5–19.4
19.5–21.3
21.4–24.4
24.5–25.9
26.0–27.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
10.5–12.0
12.1–13.6
13.7–15.6
15.7–17.1
17.2–19.4
19.5–20.9
21.0–22.2
22.3–25.3
25.4–26.9
27.0–30.2
—
30.3–33.3
33.4–35.3
—
35.4–41.5
41.6–45.0
45.1–52.3
52.4–55.7
55.8–60.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
30.0–33.5
33.6–36.4
36.5–39.6
—
39.7–43.6
43.7–46.5
46.6–51.6
51.7–54.4
54.5–58.0
58.1–63.0
63.1–67.7
67.8–72.4
—
—
—
—
—
72.5–80.0
80.1–88.1
88.2–91.5
91.6–96.8
96.9–99.0
99.1–108.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
56.9–60.9
61.0–63.9
64.0–67.7
67.8–72.4
72.5–77.7
77.8–85.9
86.0–91.9
92.0–96.7
96.8–105
—
—
106–115
116–130
E6
E7
E8
E9
E11
E12
E13
E14
E16
E17
E18
E19
E23
E24
E26
E27
E28
E29
E31
E32
E33
E34
E36
E37
E38
E39
E41
E42
E44
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56
E57
E60
E61
E62
E65
E66
E67
E69
E70
E71
E72
E73
E73A
E74
E76
E77
E78
E79
E80
E88
E89
E91
E92
E93
E94
E96
E97
E98
E99
E101
E102
E103
E104
8/154
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
2.27–2.54
2.55–2.69
2.70–2.88
2.89–3.14
3.15–3.40
3.41–3.81
3.82–4.25
4.26–4.62
4.63–5.09
5.10–5.61
5.62–5.91
5.92–6.15
6.16–6.70
6.71–7.54
7.55–8.29
8.30–8.99
9.00–9.85
9.86–10.4
10.5–12.0
12.1–13.6
13.7–15.6
15.7–17.0
17.1–19.4
19.5–20.9
21.0–22.2
22.3–25.3
25.4–26.9
27.0–30.2
—
30.3–33.3
33.4–36.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Table 238 for Class 48
Full Load Amps
List Price $
Product Category: NEMA
48DC
48GC
48HA
48JA
Heater
Catalog No
0.30–0.32
0.33–0.35
0.36–0.38
0.39–0.41
0.42–0.44
0.45–0.49
0.50–0.54
0.55–0.58
0.59–0.63
0.64–0.67
0.68–0.73
0.74–0.81
0.82–0.87
0.88–0.94
0.95–1.00
1.01–1.10
1.11–1.26
1.27–1.40
1.41–1.58
1.59–1.74
1.75–1.85
1.86–1.99
2.00–2.11
2.12–2.31
2.32–2.59
2.60–2.75
2.76–2.95
2.96–3.21
3.22–3.48
3.49–3.89
3.90–4.35
4.36–4.73
4.74–5.21
5.22–5.74
5.75–6.05
6.06–6.46
6.47–6.95
6.96–8.09
8.10–9.29
9.30–10.4
—
10.5–10.9
11.0–12.0
12.1–14.5
14.6–16.8
16.9–18.4
18.5–20.9
21.0–22.5
22.6–24.3
24.4–27.2
27.3–29.2
29.3–30.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
16.9–18.4
18.5–20.9
21.0–22.5
22.6–24.7
24.8–27.2
27.3–29.2
29.3–32.0
32.1–34.9
—
35.0–37.8
37.9–41.7
41.8–45.9
46.0–49.0
49.1–54.2
54.3–60.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
27.1–30.0
30.1–33.2
33.3–35.7
35.8–39.4
39.5–43.4
43.5–46.9
—
47.0–51.5
51.6–57.0
57.1–62.8
62.9–69.1
69.2–75.0
75.1–83.3
—
—
—
—
—
—
83.4–86.9
87.0–92.9
93.0–100.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
50.0–55.9
56.0–60.9
61.0–65.9
66.0–69.9
70.0–75.9
76.0–81.9
82.0–86.9
87.0–92.9
93.0–97.9
98.0–107.9
108–113.9
114–125.9
126–138.9
139–153.9
154–163.9
164–180.9
E3
E4
E5
E6
E7
E8
E9
E11
E12
E13
E14
E16
E17
E18
E19
E23
E24
E26
E27
E28
E29
E31
E32
E33
E34
E36
E37
E38
E39
E41
E42
E44
E46
E47
E48
E49
E50
E51
E52
E53
E54
E55
E56
E57
E60
E61
E62
E65
E66
E67
E69
E70
E71
E72
E73
E73A
E74
E76
E77
E78
E79
E80
E88
E89
E91
E92
E93
E94
E96
E97
E98
E99
E101
E102
E103
E104
E106
E107
List Price $
Siemens Industry, Inc.
Industrial Controls Catalog
Overload Relay Heater Tables
Full Load Motor Amps, Single Phase, Trip Class 10 – Tables 313, 316
Selection
Table 313 for Class 14, 22 (1-Phase)
Full Load Amps
Size 00, 0, 1
Size 1P
Size 2, 21⁄2
Heater
Catalog No
1.85–2.05
2.06–2.35
2.36–2.64
2.65–2.96
2.97–3.31
3.32–3.51
3.52–3.87
3.88–4.31
4.32–4.79
4.80–5.21
5.22–5.75
5.76–6.11
6.12–6.95
6.96–7.73
7.74–8.47
8.48–9.52
9.53–10.4
10.5–11.1
11.2–12.4
12.5–13.5
13.6–15.1
15.2–16.6
16.7–17.6
17.7–18.8
18.9–21.6
21.7–22.7
22.8–25.3
—
—
—
—
—
—
—
—
—
—
—
1.85–2.05
2.06–2.35
2.36–2.64
2.65–2.96
2.97–3.31
3.32–3.51
3.52–3.87
3.88–4.31
4.32–4.79
4.80–5.21
5.22–5.75
5.76–6.11
6.12–6.95
6.96–7.73
7.74–8.47
8.48–9.52
9.53–10.4
10.5–11.1
11.2–12.4
12.5–13.5
13.6–15.1
15.2–16.6
16.7–17.6
17.7–18.8
18.9–21.6
21.7–22.7
22.8–25.3
25.4–26.6
26.7–30.1
30.2–33.0
33.1–34.1
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
18.7–19.7
19.8–21.3
21.4–22.8
22.9–24.2
24.3–26.5
26.6–29.3
29.4–32.0
32.1–35.6
35.7–37.9
38.0–40.3
40.4–44.3
44.4–49.5
49.6–52.1
52.2–53.7
53.8–60.0
K21
K22
K24
K27
K28
K29
K31
K32
K33
K34
K36
K37
K39
K41
K42
K43
K49
K50
K52
K53
K54
K55
K57
K58
K60
K61
K62
K63
K64
K67
K68
K69
K70
K72
K73
K74
K75
K76
Siemens Industry, Inc.
Industrial Controls Catalog
Table 316 for Class 48
Full Load Amps
List Price $
Product Category: NEMA
48DA
48GA
48HA
48JA
Heater
Catalog No
1.69–1.88
1.89–2.05
2.06–2.21
2.22–2.44
2.45–2.70
2.71–2.92
2.93–3.27
3.28–3.56
3.57–3.83
3.84–4.23
4.24–4.57
4.58–4.97
4.98–5.67
5.68–6.11
6.12–6.91
6.92–7.65
7.66–8.4
8.5–8.9
9.0–10.1
10.2–11.2
11.3–12.3
12.4–13.3
13.4–14.1
14.2–15.0
15.1–16.2
16.3–17.5
17.6–18.6
18.7–19.9
20.0–21.3
21.4–22.8
22.9–25.1
25.2–27.6
27.7–30.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
9.12–9.6
9.7–10.4
10.5–11.4
11.5–12.1
12.2–12.9
13.0–13.7
13.8–14.8
14.9–16.4
16.5–18.2
18.3–19.5
19.6–20.9
21.0–22.8
22.9–24.7
24.8–27.6
27.7–30.5
30.6–33.9
34.0–37.3
37.4–40.2
40.3–41.9
42.0–45.9
46.0–50.9
51.0–52.9
53.0–57.7
57.8–60.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
23.2–25.1
25.2–27.3
27.4–30.4
30.5–33.3
33.4–36.5
36.6–39.3
39.4–43.5
43.6–46.6
46.7–51.1
51.2–56.3
56.4–61.1
61.2–64.9
65.0–71.9
72.0–80.7
80.8–92.7
92.8–100.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
43.0–46.5
46.6–50.9
51.0–55.9
56.0–59.1
59.2–68.7
—
68.8–80.7
80.8–92.7
92.8–103.9
104.0–113.5
113.6–127.9
128.0–143.9
144.0–163.9
164.0–180.0
K21
K22
K23
K24
K26
K27
K28
K29
K31
K32
K33
K34
K36
K37
K39
K41
K42
K43
K49
K50
K52
K53
K54
K55
K56
K57
K58
K60
K61
K62
K63
K64
K67
K68
K69
K70
K72
K73
K74
K75
K76
K77
K78
K85
K86
K87
K89
K92
K94
K96
List Price $
8/155
Overload Relay Heater Tables
Full Load Motor Amps, 3-Phase, Trip Class 10 – Tables 332, 335
Selection
Table 332 for Class 14, 17, 18, 22, 25, 26, 30, 32, 83, 84, 87 (3-Phase)
Full Load Amps
Size 00, 0, 1
1.52–1.65
1.66–1.79
1.80–1.94
1.95–2.15
2.16–2.37
2.38–2.56
2.57–2.87
2.88–3.13
3.14–3.37
3.38–3.72
3.73–4.00
4.01–4.35
4.36–4.99
5.00–5.38
5.39–5.79
5.80–6.43
6.44–6.83
6.84–7.83
7.84–8.23
8.24–9.59
9.60–9.90
10.0–10.7
10.8–11.6
11.7–12.3
12.4–13.4
13.5–14.2
14.3–15.1
15.2–17.5
17.6–18.7
18.8–20.0
20.1–21.5
21.6–23.9
24.0–25.8
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
8/156
3
Size 1 ⁄4
1.52–1.65
1.66–1.79
1.80–1.94
1.95–2.15
2.16–2.37
2.38–2.56
2.57–2.87
2.88–3.13
3.14–3.37
3.38–3.72
3.73–4.00
4.01–4.35
4.36–4.99
5.00–5.38
5.39–5.79
5.80–6.43
6.44–6.83
6.84–7.83
7.84–8.23
8.24–9.59
9.60–9.90
10.0–10.7
10.8–11.6
11.7–12.3
12.4–13.4
13.5–14.2
14.3–15.1
15.2–17.5
17.6–18.7
18.8–20.0
20.1–21.5
21.6–23.9
24.0–25.8
25.9–29.5
—
29.6–32.7
32.8–36.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Size 2, 2 ⁄2
1
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
12.1–12.7
12.8–13.5
13.6–14.6
14.7–15.9
16.0–16.9
17.0–18.2
18.3–19.5
19.6–20.9
21.0–23.1
23.2–25.4
25.5–27.9
—
28.0–30.5
30.6–33.5
33.6–37.2
37.3–40.7
40.8–43.0
43.1–47.9
48.0–52.7
52.8–58.3
58.4–60.0
—
—
—
—
—
—
—
—
—
—
Size 3, 3 ⁄2
1
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
36.8–40.0
40.1–42.4
42.5–46.3
46.4–49.6
49.7–52.3
52.4–57.5
57.6–63.9
64.0–67.9
68.0–74.3
74.4–77.9
78.0–83.1
83.2–91.4
91.5–99.9
100.0–108.0
—
—
—
—
Size 4
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
49.7–52.3
52.4–57.5
57.6–63.0
63.1–68.1
68.2–74.3
74.4–79.9
80.0–87.4
87.5–90.0
90.1–100.0
100.1–108.0
108.1–119.0
119.1–130.0
—
—
Table 335 for Class 48
Heater
Catalog No List Price $
K21
K22
K23
K24
K26
K27
K28
K29
K31
K32
K33
K34
K36
K37
K39
K41
K42
K43
K49
K50
K52
K53
K54
K55
K56
K57
K58
K60
K61
K62
K63
K64
K67
K68
K69
K70
K72
K73
K74
K75
K76
K77
K78
K83
K85
K86
K87
K88
K89
K90
K92
K94
K96
Product Category: NEMA
Full Load Amps
48DC
48GC
48HA
48JA
1.56–1.69
1.70–1.84
1.85–1.98
1.99–2.19
2.20–2.43
2.44–2.63
2.64–2.95
2.96–3.21
3.22–3.45
3.46–3.81
3.82–4.10
4.11–4.46
4.47–5.10
5.11–5.49
5.50–6.21
6.22–6.76
6.77–7.62
7.63–8.07
8.08–9.19
9.20–10.0
10.1–11.0
11.1–12.0
12.1–12.7
12.8–13.5
13.6–14.5
14.6–15.7
15.8–16.7
16.8–17.9
18.0–19.2
19.3–20.5
20.6–22.5
22.6–24.8
24.9–27.6
27.7–30.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
18.0–19.2
19.3–20.5
20.6–22.5
22.6–24.8
24.9–27.6
—
27.7–30.1
30.2–33.1
33.2–36.7
36.8–40.1
40.2–45.5
45.6–47.9
48.0–52.7
52.8–55.1
55.2–60.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
23.2–25.1
25.2–27.3
27.4–30.4
30.5–33.3
33.4–36.5
36.6–39.3
39.4–43.5
43.6–46.6
46.7–51.1
51.2–56.3
56.4–61.1
61.2–64.9
65.0–71.9
72.0–80.7
80.8–92.7
92.8–100.0
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
43.0–46.5
46.6–50.9
51.0–55.9
56.0–59.1
59.2–68.7
—
68.8–80.7
80.8–92.7
92.8–103.9
104.0–113.5
113.6–127.9
128.0–143.9
144.0–163.9
164.0–180.0
Heater
Catalog No
List Price $
K21
K22
K23
K24
K26
K27
K28
K29
K31
K32
K33
K34
K36
K37
K39
K41
K42
K43
K49
K50
K52
K53
K54
K55
K56
K57
K58
K60
K61
K62
K63
K64
K67
K68
K69
K70
K72
K73
K74
K75
K76
K77
K78
K85
K86
K87
K89
K92
K94
K96
Siemens Industry, Inc.
Industrial Controls Catalog
Replacement Parts
Starters and Contactors – AC Coils
Selection
Ordering Information
䊳
4th character of starter or contactor catalog number indicates model.
AC Coils — For Class 14, 17, 18, 22, 25, 26, 30, 32, 36, 37, 40, 43, 83, 84, 87, 88
Volts
Size
Model
60Hz
50Hz
Catalog Number
24
120
110–120/220–240
208
220–240
277
220–240/440–480
440–480
575–600
24
120
110–120/220–240
208
220–240
277
220–240/440–480
440–480
575–600
24
120
120/220–240
208
220–240
277
220–240/440–480
440–480
575–600
23-26
110-127
200-220
220-240
240-277
380-420
440-480
575-600
23-26
110-127
200-220
220-240
240-277
380-420
440-480
575-600
23-26
110-127
200-220
220-240
240-277
380-420
440-480
575-600
24
110
110/190–220
—
190–220
240
190–220/380–440
380–440
550
24
110
110/190–220
—
190–220
240
190–220/380–440
380–440
550
24
110
110/190–220
—
190–220
240
190–220/380–440
380–440
550
23-26
110-127
200-220
220-240
240-277
380-420
440-480
575-600
23-26
110-127
200-220
220-240
240-277
380-420
440-480
575-600
23-26
110-127
200-220
220-240
240-277
380-420
440-480
575-600
75D73070J
75D73070F
75D73070A
75D73070D
75D73070G
75D73070L
75D73070C
75D73070H
75D73070E
75D73251J
75D73251F
75D73251A
75D73251D
75D73251G
75D73251L
75D73251C
75D73251H
75D73251E
75D70131J
75D70131F
75D70131A
75D70131D
75D70131G
75D70131L
75D70131C
75D70131H
75D70131E
3RT1966-5AB31
3RT1966-5AF31
3RT1966-5AM31
3RT1966-5AP31
3RT1966-5AU31
3RT1966-5AV31
3RT1966-5AR31
3RT1966-5AT31
3RT1965-5AB31
3RT1965-5AF31
3RT1965-5AM31
3RT1965-5AP31
3RT1965-5AU31
3RT1965-5AV31
3RT1965-5AR31
3RT1965-5AT31
3RT1975-5AB31
3RT1975-5AF31
3RT1975-5AM31
3RT1975-5AP31
3RT1975-5AU31
3RT1975-5AV31
3RT1975-5AR31
3RT1975-5AT31
00–21⁄2
P
U (ESP200)
3 , 31⁄2
P
U (ESP200)
4
G
U (ESP200)
4, 5
V (Vacuum)
5
P
6
P
V (Vacuum)
7
H
100-250
150-500
100-250
150-500
75ZAF750-70
75ZAF750-71
8
H
100-250
100-250
75ZAF1650-70
List Price $
Set
of 2 coils. Recommend to change printed circuit
board when changing coils. 49ZP1650 see page 8/158.
Siemens Industry, Inc.
Industrial Controls Catalog
Product Category: NEMA
8/157
Replacement Parts
Starters and Contactors – DC Coils, Late Break Aux Contacts, Rectifiers, Contact Kits
Selection
Ordering Information
䊳
䊳
4th character of starter or contactor catalog number indicates model.
DC Coils for Size 00-4 require Late Break Interlock.
DC Coils — For Class 14, 17, 18, 22, 25, 26, 30, 32, 40, 43
Size
Model
00–21⁄2
P
U (ESP200)
3, 31⁄2
P
U (ESP200)
4
G
U (ESP200)
4, 5
V (Vacuum)
Volts DC
Catalog Number
12
24
32
48
125
250
12
24
32
48
125
250
48
125
250
23-26
42-48
110-127
240-277
75D73070R
75D73070S
75D73070T
75D73070U
75D73070V
75D73070W
75D73251R
75D73251S
75D73251T
75D73251U
75D73251V
75D73251W
75D70131U
75D70131V
75D70131W
3RT1966-5AB31
3RT1966-5AD31
3RT1966-5AF31
3RT1966-5AU31
List Price $
Note: For sizes 7 & 8 contactors the AC coils are used for DC see page 16-155.
Board for Size 8 Contactor
Late Break Auxiliary Contacts
Control Size
Model
Catalog Number List Price $
Control Size
Model
Catalog Number List Price
00–4
P, G, S, T
49AB01LB
8
H
49ZP1650
Contact Kits – Single Pole Stationary and Movable Contacts, Contact Spring
Description
Size
Number of Poles in Kit
3
Class 14, 17, 18, 22, 25,
26, 30, 32, 36, 37, 40, 43,
83, 84, 87, 88
14, 40
Internal Aux Contact (00-1- ⁄4)
00
0
1
13⁄4–1P
2
21⁄2
3
31⁄2
4
4 (Vacuum)
5
5 (Vacuum)
6
6 (Vacuum)
7
8
1
1
1
1
1
3 (Bottles)
3
3 (Bottles)
3
3 (Bottles)
3
3
Model
(4th position in part number)
P, U
P, U
P, U
P, U
P, U
P, U
P, U
P, U
P, U
G, T
V, C
P
V, C
P
V, C
H
H
Catalog Number
List Price $
75AF14
75BF14
75CF14
75DF14
75EF14
75FP14
75GP14
75HF14
75IF14
75JG14
3RT1964-6V
3RT1966-6A
3RT1966-6V
3RT1976-6A
3RT1976-6V
49ZL750
49ZL1650
Armature and Magnet Kits
Size
Catalog Number
00–21⁄2
49AMSA2
3–31⁄2
49AMSA3
4
49AMSA4
List Price $
On
3-phase controls, all 3-poles should be replaced 3 kits required.
8/158
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Replacement Parts
Starters and Contactors – Coil VA Ratings and Overload Relays
Selection
Coil VA Ratings
Device Type
NEMA Starter
Lighting Contactor
Mechanically Held (CLM)
Lighting Contactor
Electrically Held Held (LE)
Contactor Size
Amps
00 thru 2 1/2
3 thru 3 1/2
4
5
6
7
8
4,5,6 (Vacuum)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
20
30
60
60
100 - 200
100 - 200
300 - 400
20
20
20
20
20
20
20
20
20
20
20
20
20
20
30
30
30
30
30
30
30
60
60
60
60
60
60
60
100
100
100
100
100
100
100
200
300
400
Volts
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
24
120
208
240
277
480
600
24
120
208
240
277
480
600
24
120
208
240
277
480
600
24
120
208
240
277
480
600
24
120
208
240
277
480
600
All Voltages
Electrically
Held
Number of Poles
Total Inrush VA
Total Sealed VA
—
—
—
—
—
—
—
—
2-12
2-5
2-3
4-5
2-3
4-5
3
3
3
3
3
3
3
3
12
12
12
12
12
12
12
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
218
310
510
590
830
850
1900
630
6
40
40
40
200
130
550
49.6
51.3
75.79
86.78
79.1
83.7
84.1
73.31
75.1
73.97
89.15
78.55
84
81.9
49.67
51.94
76.57
64.44
77.85
83.6
82.1
74.94
75.77
78.73
89.92
84.89
87.6
85.4
182.28
191.42
187.78
215.32
175.92
198.2
171.1
300
590
830
25
26
51
6.7
9.2
12
48
7.4
625
410
410
600
900
1300
1600
6.9
6.57
11.94
14.25
11.97
12.9
13.2
12.66
13.1
13.25
14.85
12.77
12.9
13.4
7.08
6.48
11.78
8.99
14.2
13.1
13.4
13.16
13.59
12.05
14.42
12.93
12.7
13.8
32.85
32.26
31.15
35.63
30.62
34.8
29.6
5.8
6.7
9.2
Overload Relays – For Class 14, 17, 18, 22, 25, 26, 30, 32, 83, 84, 87
Size
Half
Size
Ambient Comp Bimetal
Model
00–1
—
P
1P
—
—
13⁄4
P
P
2
—
P
—
21⁄2
P
3
—
4
—
31⁄2
—
P
P
G
Number Poles
Catalog Number (1) NC
1
3
1
3
1
3
1
3
3
3
3
48DC18AA3
48DC38AA3
48EC18AA3
48EC38AA3
48GC18AA3
48GC38AA3
48GC18AA3
48GC38AA3
48HC38AA3
48HC38AA3
48JC38AA3
List Price $
Catalog Number (1) NO/NC
List Price $
48DC39AA3
48EC39AA3
48GC39AA3
48GC39AA3
For Starter and Contactor replacement parts not found in this section, please refer to Field Modification kits found starting on page 8/81.
For
replacement Solid State overload relays, please see the Overload Relay section
found starting on page 8/49.
Siemens Industry, Inc.
Industrial Controls Catalog
Includes
Product Category: NEMA
overload mounting plate to be coupled to contactor mounting plate.
8/159
Replacement Parts
Lighting and Heating Contactors, Type LE, CLM, CMF, CMN
Selection
AC Coils – 20-400 Amps
Type
LE
3 RT 1 9 5 5 - 5 A F 3 1
Contactor
Size
Catalog Number
24VAC
120VAC
208VAC
240VAC
277VAC
480VAC
600VAC
20, 30, 60 Amp 75D70646J
75D70646F
75D70646D
75D70646G
75D70646L
75D70646H
75D70646E
100 Amp
75D54772J
75D54772F
75D54772D
75D54772G
75D54772L
75D54772H
75D54772E
200 Amp
3RT1955-5AB31 3RT1955-5AF31
3RT1955-5AM31 3RT1955-5AP31
3RT1955-5AU31
3RT1955-5AR31 3RT1955-5AT31
300 Amp
3RT1965-5AB31 3RT1965-5AF31
3RT1965-5AM31 3RT1965-5AP31
3RT1965-5AU31
3RT1965-5AR31 3RT1965-5AT31
400 Amp
3RT1975-5AB31 3RT1975-5AF31
3RT1975-5AM31 3RT1975-5AP31
3RT1975-5AU31
3RT1975-5AR31 3RT1975-5AT31
List
Price $
Main Contacts (Includes 3 Moving and 6 Fixed Contacts)
Type
LE
3 RT 1 9 6 5 - 6 A
Contactor Size
Catalog Number
20–100 Amp
Not Replaceable
200 Amp
3RT1956-6A
300 Amp
3RT1965-6A
400 Amp
3RT1975-6A
List Price $
—
Lighting Contact Assembly - 20 Amp (Power Poles)
Type
Catalog
Number
Contactor Size
(Verify catalog number on
side of contact assembly)
List Price $
49LN02A, 2 NC Contacts Non-Stackable
LE
49LN20A, 2 NO Contacts Non-Stackable
20 Amp
49LS20A, 2 NO Contacts Stackable
49LS10A, 1 NO Contact Stackable
AC Coils 20 Amps
CLM4097341
Type
Contactor
Size
Number
of Poles
120V, 60Hz
110V, 50Hz
CLM
20 Amp
2–12
CLM4097341
List
Price $
240V, 60Hz
208V, 50Hz
List
Price $
CLM4097342
277V
50/60Hz
List
Price $
480V, 60Hz
440V, 50Hz
CLM4097343
List
Price $
CLM4097344
AC Coils 30–400 Amps
CLMC4C120
CLMGU3C120
Type
Contactor
Size
CLM†C
30 Amp
CLM†D
60 Amp
CLM†E
100, 200
Amp
CLM†G
Latching Coil
Unlatch Coil
CLM†H
Latching Coil
Unlatch Coil
Catalog Number
Number
of Poles
24V AC
120V AC
208V AC
220/240V AC
277V AC
480V AC
600V AC
2–3-Pole
4-Pole
5-Pole
2–3-Pole
4-Pole
5-Pole
2–3-Pole
4-Pole
5-Pole
CLMC4C024
CLMC4C024
CLMC5C024
CLMD3C024
CLMD5C024
CLMD5C024
CLME3C024
CLME5C024
CLME5C024
CLMC4C120
CLMC4C120
CLMC5C120
CLMD3C120
CLMD5C120
CLMD5C120
CLME3C120
CLME5C120
CLME5C120
CLMC4C208
CLMC4C208
CLMC5C208
CLMD3C208
CLMD5C208
CLMD5C208
CLME3C208
CLME5C208
CLME5C208
CLMC4C240
CLMC4C240
CLMC5C240
CLMD3C240
CLMD5C240
CLMD5C240
CLME3C240
CLME5C240
CLME5C240
CLMC4C277
CLMC4C277
CLMC5C277
CLMD3C277
CLMD5C277
CLMD5C277
CLME3C277
CLME5C277
CLME5C277
CLMC4C480
CLMC4C480
CLMC5C480
CLMD3C480
CLMD5C480
CLMD5C480
CLME3C480
CLME5C480
CLME5C480
CLMC4C600
CLMC4C600
CLMC5C600
CLMD3C600
CLMD5C600
CLMD5C600
CLME3C600
CLME5C600
CLME5C600
300 Amp
2–3-Pole
2–3-Pole
—
—
CLMGL3C120 CLMGL3C208 CLMGL3C240 CLMGL3C277 CLMGL3C480 CLMGL3C600
CLMGU3C120 CLMGU3C208 CLMGU3C240 CLMGU3C277 CLMGU3C480 CLMGU3C600
400 Amp
2–3-Pole
2–3-Pole
—
—
CLMHL3C120 CLMHL3C208 CLMHL3C240 CLMHL3C277 CLMHL3C480 CLMHL3C600
CLMHU3C120 CLMHU3C208 CLMHU3C240 CLMHU3C277 CLMHU3C480 CLMHU3C600
List
Price $
.
Control Module Rectifier
Type
Device
Contactor Size
Number of Poles
Catalog Number
CLM
CLM†C to
CLM†F
30–200 Amps
All
CLMKCMR
Product Category: IEC.
Coil kits for 20 amp CLM
contactors include the coil
clearing auxiliary contact.
8/160
List Price $
For
30–200 amp CLM contactors, in the event that
either the coil or the control module fails, it is
recommended that both be replaced.
Product Category: NEMA
Siemens Industry, Inc.
Industrial Controls Catalog
Replacement Parts
Lighting Contactors, CLM, CMB, CMF, CMN & Combination Replacement Handles
Selection
Ordering Information
䊳
䊳
For CLM: 5th character of contactor catalog number indicates Frame Size.
For CMB, CMF, CMN: 4th character of contactor catalog number indicates Frame Size.
Main Contacts 20 Amp Lighting Contactors
Type
Contactor
Size
Number of
Poles
Location
Catalog
Number
CLM
20 Amp
2
3
4
6
Top or Bottom
Top
Top or Bottom
Top or Bottom
CLM4097331
CLM4097332
CLM4097333
CLM4097334
CLM4097334
List
Price $
Main Contacts 30–400 Amp Lighting Contactors
Type
CLM
Frame
Size
Contactor
Size
Number of
Poles
Catalog
Number
C
30 Amp
2
3
4
5
CLMCCK02
CLMCCK03
CLMCCK04
CLMCCK05
D
60 Amp
2
3
4
5
CLMDCK02
CLMDCK03
CLMDCK04
CLMDCK05
E
100 Amp
2
3
4
5
CLMECK02
CLMECK03
CLMECK04
CLMECK05
F
200 Amp
2
3
4
5
CLMFCK02
CLMFCK03
CLMFCK04
CLMFCK05
G
300 Amp
2
3
CLMGCK02
CLMGCK03
H
400 Amp
2
3
CLMHCK02
CLMHCK03
List
Price $
Auxiliary Contact Blocks 20 Amp Lighting Contactors
Type
Contactor
Size
CLM
20 Amp
Contacts
Catalog
Number
1 Form C NO, NC Contact
2 Form C NO, NC Contacts
CLM4097291
CLM4097292
List
Price $
Auxiliary Contact Blocks 30–400 Amp Lighting Contactors
Type
Frame
Size
Contactor
Size
C to F
30–200 Amps
G to H
300–400 Amps
CLM
CLMFCAK11
Contact
Configuration
Catalog
Number
List
Price $
1 NO and 1 NC
2 NC
2 NO
1 Coil Clearing
NO and NC
CLMFCAK11
CLMFCAK02
CLMFCAK20
CLMFCCK11
1 NO and 1 NC
2 NC
2 NO
1 Coil Clearing
NO and NC
CLMHCAK11
CLMHCAK02
CLMHCAK20
CLMHCCK11
Combination Starters Class 17, 18, 25, 26 & 32
Replacement Handle Assemblies
NEMA 1, 4, 12 Enclosure Class 17, 25, 32
Disc
Standard
List
Extra
Size
Width
Price $
Wide
30-100A
200A
Maximum
Maximum
75D68257103
75D68257105
75D68257103
—
List
Price $
—
NEMA 1, 4, 12 Enclosure Class 18, 26, 32
Circuit
Standard
List
Extra
Breaker Width
Price $
Wide
3-100A
125A
150A
75D68257080
75D68257096
75D68257089
75D68257080
—
—
List
Price $
—
—
1 block per contactor.
2 blocks per contactor.
Siemens Industry, Inc.
Industrial Controls Catalog
Product Category: NEMA
8/161
Replacement Parts
Notes
8/162
Siemens Industry, Inc.
Industrial Controls Catalog
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c320 44.290368, Sun Jun 10 2007 17:23:03 Modify Date : 2009:08:27 10:31:24-05:00 Create Date : 2009:08:27 10:30:50-05:00 Metadata Date : 2009:08:27 10:31:24-05:00 Document ID : uuid:265503c8-f31f-4244-8cd4-ff20d6fd843e Instance ID : uuid:7f407a24-2e52-4431-9a1d-789c007eb5b6 Format : application/pdf Producer : Creo Normalizer JTP Trapped : False Page Count : 162EXIF Metadata provided by EXIF.tools