AnnotateLumiere

156423-Brochure 156423-Brochure 156423-Brochure 662401 Batch5 unilog cesco-content

156423-Brochure 156423-Brochure 156423-Brochure 662400 Batch5 unilog cesco-content

2014-10-17

: Pdf 115339-Attachment 115339-Attachment 662400 Batch10 unilog

Open the PDF directly: View PDF PDF.
Page Count: 3

Catalog #
Project
Comments
Prepared by
Type
Date
COOPER LIGHTING - LUMARK®
SPECIFICATION FEATURES
Construction
HOUSING: Heavy-duty, formed
steel housing with an open air
ballast for cooler operation is
finished in a white polyester
powder coat.
Electrical
BALLAST: High power factor ballast
with class H insulation. Minimum
starting temperature is -40°C (-
40°F) for HPS and -30°C (-20°F) for
MH. SOCKET: Mogul-base socket
standard for HPS. For Metal Halide,
protected socket standard, for use
with "O" Open rated protected
Metal Halide lamps only. HANDS-
FREE RELAMPING: Internal
hangers for reflector/refractor
provide toolless, hands-free
relamping. Reflector is latched to
ballast housing for easy access to
lamp.
Optical
SEALED OPTICS: Sealed Optics
Enclosed and gasketed optics seal
out dirt and other contaminants.
REFLECTOR: Computer designed,
faceted reflector provides
maximum photometric
performance. LENS: 100% virgin
UV stabilized acrylic refractor.
Mounting
Easy slide-on die-cast aluminum
mounting box with tapped opening
for 3/4" conduit.
EP
ENTERPRISE 28
70 - 450W
High Pressure Sodium
Pulse Start Metal Halide
Metal Halide
ALUMINUM LOW-BAY
The Enterprise 28 industrial low-bay luminaire combines a round, faceted
reflector with an injection-molded lens to provide an efficient,
symmetrical beam pattern. U.L. listed and labeled for damp location. CSA
Certified. The Enterprise 28 combines durable construction with precise
optics for mounting heights below 20'. Perfect for warehouses, gyms,
assembly areas, food processing plants and hangars.
DESCRIPTION
S
Y
S
T
E
M
S
C
E
R
T
I
F
I
E
D
24”
[610mm]
28” [711mm]
DIMENSIONS
TECHNICAL DATA
EISA Compliant G
55°C Maximum Ambient Temperature
90°C Supply Wiring
ENERGY DATA
Reactor Ballast Input Watts
70W HPS NPF/HPF (82 Watts)
100W HPS NPF/HPF (118 Watts)
150W HPS NPF/HPF (175 Watts)
150W MH NPF/HPF (185 Watts)
CWI Ballast Input Watts
250W HPS HPF (300 Watts)
250W MH HPF (300 Watts)
400W HPS HPF (465 Watts)
400W MH HPF (475 Watts)
CWA Ballast Input Watts
175W MP HPF (198 Watts) G
200W MP HPF (227 Watts) G
250W MP HPF (283 Watts) G
320W MP HPF (365 Watts) G
350W MP HPF (400 Watts) G
400W MP HPF (452 Watts) G
400W HPS HPF (465 Watts)
450W MP HPF (508 Watts) G
SHIPPING DATA
Approximate Net Weight:
35 lbs. (16 kgs.)
2013-07-11 16:07:31
NOTE: Specifications and dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
ADH082408 pc
2010-11-09 11:25:04
EP ENTERPRISE 28
Coefficients Of Utilization
Effective floor cavity reflectance 20%
%03%05%07%08cr
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10
RCR
1 90858178 87837976 797673 757371
2 81746862 79726661 686460 656158
3 73645651 71625550 595349 565247
4 67564842 64544742 524641 504440
5 60494135 58484034 453934 433833
6 55433429 53423428 403328 383227
7 50372924 48362923 352823 332723
8 45332520 44322520 312420 302419
9 42292217 40292217 282116 262016
10 39 26 19 14 37 26 19 14 25 18 14 24 18 14
3
5
7
9
11
1
90
30
CP/1000
60
HPEP-R28-400
400-Watt HPS
50,000-Lumen Clear Lamp
Spacing Criterion 1.8
Zone %Lamp Zone %Lamp
0-30 13.10 0-90 81.10
0-40 23.70 90-180 02.90
0-60 58.50 Total 83.90
Candlepower
Degree CP
0 8193
5 7970
10 7787
15 7697
20 7700
25 7810
30 7902
35 8288
40 9391
45 10780
50 11426
55 10231
60 8265
65 6131
70 4603
75 3300
80 2237
85 1420
90 908
Coefficients Of Utilization
Effective floor cavity reflectance 20%
%03%05%07%08cr
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10
RCR
1 89848077 86827875 787572 747269
2 80736661 77716560 676258 646057
3 72635549 70615449 585247 555046
4 65554741 63534640 514439 484339
5 59484034 57463933 443833 423632
6 54423328 52413327 393227 373126
7 49362823 47352822 342722 322622
8 45322519 43322419 302319 292318
9 41292116 40282116 272016 262016
10 38 26 19 14 37 25 19 14 24 18 14 23 18 13
1.9
3.9
5.8
7.7
9.7
1.3
90
30
CP/1000
60
MPEP-R28-400
400-Watt MP
44,000-Lumen Clear Lamp
Spacing Criterion 1.8
Zone %Lamp Zone %Lamp
0-30 12.90 0-90 80.10
0-40 22.60 90-180 02.90
0-60 56.70 Total 83.00
Candlepower
Degree CP
0 6134
5 6260
10 6623
15 6824
20 6713
25 6711
30 6699
35 6773
40 7175
45 8112
50 9703
55 9502
60 8353
65 5675
70 4030
75 2924
80 1981
85 1276
90 839
PHOTOMETRICS
2013-07-11 16:07:31
NOTE: Specifications and dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
ADH082408 pc
2010-11-09 11:25:04
EP ENTERPRISE 28
VOLTAGE CHART
120/208/240/277V (wired 277V)
120/277/347V (wired 347V)
120/208/240/277/480V (wired 277V)
TT= Triple-Tap
5T= 5-Tap
8
MT= Multi-Tap
Pulse Start Metal Halide (MP) 70, 100, 175, 200, 250, 320, 350, 400, 450W
Metal Halide (MH) 175, 250, 400W
High Pressure Sodium (HP) 70, 100, 150, 250, 400W
LAMP TYPE WATTAGE
2013-07-11 16:07:31
Voltage
4
120V 120V=
208V 208V=
240V 240V=
277V 277V=
347V
347V
=
480V
480V
=
MT
Multi-Tap,
wired 277V
5
=
TT
Triple-Tap,
wired 347V
6
=
5T
5-Tap7
=
Lamp
Wattage
MP
100 100W=
175 175W=
250 250W=
320
320W
=
400
400W
=
MH
2
175
175W
=
250
250W
=
400
400W
=
HP
100
100W
=
250
250W
=
400
400W
=
Accessories
14
C3
3' Cord-No Plug - Requires FH-1, FL-1, or
SHK
9
=
PC3
3' Cord with NEMA Plug - (120V-L5,
208V-L6-15P, 347V-L37-20P and
480V-L8-20P) Other cord lengths are
available by specifying length (PC6 for 6'
cord). Requires FH-1 or FL-1, or SHK. Use
with TPPH-NEMA. Specify Voltage.
9
=
PHC
Power Hook Cord and Non-NEMA plug
configuration. Must be used with FL-1 and
TPPH (Thru-Way Pendant Power Hook)
=
PHC-NEMA
Power Cord and NEMA plug - 18"
Power Cord and 20 Amp NEMA
plug configuration. Must be used
with FL-1 and TPPH-NEMA
(Thru-Way Pendant Power Hook)
=
WG28/EP
Wire Guard
=
MBT
Twin Mount Bracket (Fixtures must be same
voltage and without hooks, loops or plugs.)
=
TPPH
Thru-Way Pendant Power Hook. Requires
FL-1 and PHC. Specify Voltage.
=
TPPH-F
Thru-Way Pendant Power Hook Single
Fuse, 120, 277 or 347 Volt. Requires
FL-1 and PHC. Specify Voltage.
=
TPPH-F2
Thru-Way Pendant Power Hook -
Double Fused, 208, 240, or 480 Volt.
Requires FL-1 and PHC. Specify
Voltage.
=
TPPH-F-QD
Thru-Way Pendant Power Hook
Single Fuse, Quick Disconnect.
Requires FL-1 and PHC. Specify
Voltage (120, 277, or 347V)
=
TPPH-F2-QD Thru-Way Pendant Power Hook
Double Fuse, Quick Disconnect.
Requires FL-1 and PHC. Specify
Voltage (208, 240, or 480V)
=
TPPH-NEMA
Thru-Way Pendant Power Hook.
Requires FL-1 and
PHC-XXXV-NEMA. (Specify
=
FH-1 Fixture Hook
=
FL-1 Fixture Loop
=
SHK Hook with Safety Screw
=
TWMBS Thru-Way Mounting Box15
=
Options
C3 3' Cord with no plug (Specify Voltage)9
=
PC3 3' Cord with NEMA Plug (120V-L5-15P,
208V-L6-15P, 347V-L37-20P, AND
480V-L8-20P) Other cord lengths are
available by specifying length (PC6 for 6'
Cord) Requires FH-1 or FL-1, or SHK.
Example: PC3-120V Use with
TPPH-NEMA. Specify Voltage.
9
=
PHC
Power Cord and Plug (18" Power Cord
and Non-NEMA plug configuration. Must
be used with FL-1 and TPPH (Thru-Way
Pendant Power Hook). Must specify
single voltage.
=
PHC-NEMA
Power Cord and NEMA Plug (18"
Power Cord and 20 AMP NEMA
plug configuration). Must be
used with FL-1 and TPPH-NEMA
(Thru-Way Pendant Power
Hook).
=
FH-1
Die-cast Aluminum Fixture Hook (with
3/4" threads for easy installation)
=
FL-1
Malleable Iron Plated Fixture Loop (with
3/4" threads for easy installation)
=
SHK
Die-cast Aluminum Fixture Hook (with
safety screw and 3/4" threads for easy
installation)
=
F1 Single Fuse (120, 277 or 347V only)=
F2 Double Fuse (208, 240 or 480V only)=
SCF 3' Aircraft Safety Cable secures
Housing to Ceiling (Alternative lengths
available. Example: SCF6 = 6' Cable)
=
QQuartz Restrike (Hot Strike Only)=
EM
Quartz Restrike with ''Delay Relay'' (Quartz
lamp strikes at both hot and cold starts)
=
EM/SC Emergency Separate Circuit10
=
L/TCB Less Top Connector Box (Housing
shipped less top connector box.
(Specify when using TWMBS
accessory)
=
LL Lamp Included11
=
CEC California Title 20 Compliant Ballast
(Applies to 250-320W and 400-450W MP
only)
=
SCR Aircraft Safety Cable-Housing to
Reflector
=
W/MWS MWS Industrial components attached
to the fixture at the factory. (Standard
cord length is 3 ft. 6 ft. and 11 ft. also
available. Please refer to MWS
Modular Wiring System section for
additional information.
=
HC LumaWatt Fixture Control Module
(Low voltage leads pulled out of top
connection box for areas requiring all
wiring to be installed in conduit)
12, 13
=
HL LumaWatt Fixture Control Module
(Allows low voltage control wire to be
daisy-chained between fixtures outside
AC conduit run similar to low voltage
intercom's, fire alarms and phone
systems)
13
=
QLL Quartz Lamp Included (Lamp is Cooper
designated product based on luminaire
requirements. Lamp is shipped separate
from luminaire unless otherewise noted)
=
FILT
Sintered Bronze filter (Sintered bronze
filter prevents the entrance of
contaminants)
=
Reflector
Diameter
R28 28'' Reflector
Diameter
=
Lamp Type
MP Pulse Start Metal
Halide
1
=
MH Metal Halide1, 2
=
HP High Pressure
Sodium
=
Reflector Type
__
Acrylic
=
PL
Polycarbonate3
=
Series
EP
Enterprise
=
Socket
OR
Open Rated
Socket for
Metal
Halide
Lamps
8
=
__
Non
Applicable
(HPS or Not
compatible
with OR
Socket)
=
1
Open Rated socket and lamp must be used.
Notes:
2
MH available in non-U.S. markets only.
3
Not recommended for use with Metal Halide lamps due to rapid yellowing typical of
polycarbonate material.
4
Products also available in non-US voltages and 50HZ for international markets. Consult your
Cooper Representative for availabiltiy and ordering information. 88% Efficient EISA Compliant
MP Fixtures not available in 347V and TT Voltages.
5
Multi-Tap ballast 120/208/240/277V wired 277V.
6
Triple-Tap ballast 120/277/347V wired 347V.
7
5-Tap ballast 120/208/240/277/480V wired 277V. 400W Metal Halide only. 88% efficient EISA
Compliant MP fixtures not available in 5-Tap Voltages.
8
Not applicable for HPS.
9
Requires FH-1or FL-1or SHK.
10
Not available with HL or HC options.
11
Lamp is shipped separately.
12
Not available with PC3, C3, PHC or MWS. Not available with single circuit MWS special order.
13
30 second time delay when switching from bright to dim. Consult individual lamp
manufacturers recommendations for compatible lamps. For use with CWA ballast only.
14
Order separately.
15
Specify L/TCB when using thru-way mounting box (TWMBS) accessory.

Navigation menu