Product Detail Manual
2014-10-23
: Pdf 115652-Attachment 115652-Attachment Batch9 unilog
Open the PDF directly: View PDF .
Page Count: 2
Download | ![]() |
Open PDF In Browser | View PDF |
SpikeShield™ Power Quality Surge Protective Devices (SPD) Wired-In Branch Panel Protection, Surge Arrestors and Surge Protective Devices Wired-In Branch Panel Protection • 100,000 Peak Amperage Capacity • Ideal for areas where space is a major consideration • Can be mounted directly to the panel through a chase nipple connection to reduce lead length and impedance • NEMA 4X housing • 200kA SCCR rating • UL 1449-3rd edition Wired-In Surge Arrestors and Surge Protective Devices • 36,000, 40,000, 50,000 and 120,000 Peak Amperage Capacity • Surge arrestors are a low cost solution that may be installed on the line side or load side of the service entrance • Excellent for OEM applications where size is an important variable • Single phase wired-in surge protective devices feature a compact design • NEMA 4X Rated • UL 1449-3rd edition Wired-In Branch Panel Protection 100,000 Peak Amp Capacity (Type 2 SPD) Service Voltage V AC Configuration Catalog Number 120/240 Single Phase 120/208 Wye* 240 Delta 240/120 Delta split phase 277/480 Wye** 480 Delta 347/600 Wye 600 Delta 1Ph. 3-wire +G 3Ph. Wye 4-wire +G 3Ph. Delta 3-wire Corner Gnd 3Ph. Delta 4-wire +G ‘High Leg’ 3Ph. Wye 4-wire +G 3Ph. Delta 3-wire Corner Gnd 3Ph. Wye 4-wire +G 3Ph. Delta 3-wire Corner Gnd HBL3W100C HBL4W100C HBL5W100C HBL6W100C HBL8W100C HBL9W100C HBL10W100C HBL11W100C HBL9W100C Note: *120/208 Wye also applies to 127/220 Wye. **277/480 Wye also applies to 220/380 Wye, 230/400 Wye and 240/415 Wye. HBLSDSA40 Wired-In Surge Arrestors, Single Phase 36,000 and Three Phase 40,000 (Type 1 / Type 2 SPD) Service Voltage V AC Configuration 120/240 Single Phase 600V Max Three Phase 1Ph. 3-wire 3Ph. 3-wire Peak Amp Capacity 36kA 40kA Mounting Means Catalog Number Back Nipple Mount Back Nipple Mount HBLSDSA36 HBLSDSA40 HBLSDSA36 Wired-In Surge Protective Devices 50,000 and 120,000 Peak Amp Capacity (Type 1/Type 2 SPD) Service Voltage V AC Configuration 120/240 Single Phase 120/240 Single Phase 1Ph. 3-wire + G 1Ph. 3-wire + G Peak Amp Capacity 50kA 120kA Mounting Means Catalog Number Side Nipple Mount Side Nipple Mount HBL3W50 HBL3W120 HBL3W50 Wiring Device-Kellems 5 SpikeShield™ Power Quality Surge Protective Devices (SPD) Surge Panel Specifications 320kA, 160kA and 120kA Service/Branch Panel Protection Electrical Specifications Catalog Number HBL3P320A HBL4P320A HBL6P320A HBL8P320A HBL10P320A HBL3P120B HBL4P120B HBL6P120B HBL8P120B HBL10P120B SCCR 200kA 200kA 200kA 200kA 200kA 200kA 200kA 200kA 200kA 200kA HBL3P160A HBL4P160A HBL6P160A HBL8P160A HBL10P160A Product Specifications Max. Surge Current per Phase: Max. Operating Temperature: Diagnostics EMI/RFI: NEMA: Listing: Warranty: Dimensions: Weight: Terminal Accommodation: Frequency: MCOV † 150/300 150/300 270/150 320/640 420/840 150/270 150/270 275/150 320/640 390/780 In 20kA 20kA 20kA 20kA 20kA 20kA 20kA 20kA 20kA 20kA Voltage Protection Rating (VPR) L-N L-G N-G 700 700 700 700 700 700 1200/700 1200/700 700 1200 1200 1200 1500 1500 1500 700 700 700 700 700 700 1000/700 1000/700 700 1200 1200 1200 1500 1500 1500 320kA, 160kA and 120kA -40ºF to 149ºF (-40ºC to 65ºC) Red & Green LED’s, Diagnostic Test Switches, Dry Contacts, Audible Alarm, Surge Counter Up to -30dB 3R/12 Metallic cULus UL1449-3rd edition type 2 SPD, UL1283, CSA C22.2 NO. 8-M1986 10 year 320kA 160kA w/ Disconnect: 6.0"D x 20.0"W x 24.0"L w/ Disconnect: 6.0"D x 20.0"W x 24.0"L w/o Disconnect: 6.0"D x 16.0"W x 20.0"L w/o Disconnect: 6.0"D x 16.0"W x 20.0"L with Disconnect: 50.6 lbs. with Disconnect: 44 lbs. without Disconnect: 38.7 lbs. without Disconnect: 15 lbs. #10 AWG to #2 AWG #10 AWG to #2 AWG 50/60 Hz 50/60 Hz L-L 1200 1200 1500/1000 1200 2500 1200 1200 1500/1200 2000 2500 120kA 6.0"D x 20.0"W x 24.0"L 17 lbs. #12 AWG to #2 AWG 50/60/400 Hz Wired-In Branch Panel Protection, Surge Arrestors and Surge Protective Devices Electrical Specifications Catalog Number HBL3W100C HBL4W100C HBL5W100C HBL6W100C HBL8W100C HBL9W100C HBL10W100C HBL11W100C HBLSDSA36 HBLSDSA40 HBL3W50 HBL3W120 In 20kA 20kA 20kA 20kA 20kA 20kA 20kA 20kA 10kA 10kA 10kA 10kA SCCR 200kA 200kA 200kA 200kA 200kA 200kA 200kA 200kA 25kA 200kA 25kA 25kA MCOV † 150/270 150/270 300 275/150 320/640 640 390/780 780 150 750/1500 150/300 150/300 Voltage Protection Rating (VPR) L-N L-G 900 1200 900 1200 N/A N/A 1000 1200 1200 2000 N/A N/A 1500 2500 N/A N/A N/A 700 2500 N/A 800 700 700 800 N-G 700 700 N/A 700 1000 N/A 1500 N/A N/A N/A N/A N/A L-L 1500 1500 1500 1500 2500 3000 3000 3000 1200 4000 1200 1200 Product Specifications Max. Surge Current per Phase: 100kA Max. Operating Temperature: -40ºF to 140ºF (-40ºC to 60ºC) Diagnostics: Green Status LED’s, Audible Alarm, Dry Contacts Dimensions: 3.1"D x 9.9"W x 4.8"H Weight: 3 lbs. Terminal Accommodation: #10 AWG 18.0" Wire Leads Frequency: 50/60 Hz EMI/RFI: Up to -30dB NEMA enclosure rating: Type 4X Listing: cULus UL1449-3rd edition type 2 SPD, UL1283 (Wye prod. only), CSA C22.2 NO. 8-M1986 Warranty: 10 year 36kA / phase -40ºF to +160ºF (-40ºC to +70ºC) Green Status LED per line 1.9"D x 2.25"W x 2.25"H .525 lbs. #14 AWG Wire Leads 50/60 Hz Up to -30dB Type 4X UL1449-3rd edition 40kA / phase -40ºF to +160ºF (-40ºC to +70ºC) Green Status LED per line 2.64"D x 3.6"W x 3.0"H 1 lbs. #12 AWG Wire Leads 50/60 Hz Up to -30dB Type 4X UL1449-3rd edition 50kA and 120kA -40ºF to +160ºF (-40ºC to +70ºC) Green Status LED per line 2.7"D x 3.0"W x 3.6"H 1.8 lbs. #12 AWG Wire Leads 50/60 Hz Up to -30dB Type 4X UL1449-3rd edition 2 year 2 year 10 year Whole House and Utility Meter Surge Protection Electrical Specifications Catalog Number HBLWH80 HBL80MPC SCCR 200kA 10kA Product Specifications Max. Surge Current per Phase: Max. Total Surge Current: Max. Operating Temperature: Diagnostics: Dimensions: Weight: Terminal Accommodation: EMI/RFI: Frequency: NEMA: Listing: Warranty: Max. Impulse Voltage (Telephone) 10 In‡ 10kA 10kA Voltage Protection Rating (VPR) MCOV † L-N L-G 150/270 900 1200 150/per phase 700 N/A HBLWH80 80 kA / phase — -40ºF to +160ºF (-40ºC to +70ºC) Green Status LED per line 3.44"D x 5.93"W x 13.18"L 8.8 lbs Terminal Block — — NEMA 1 UL 1449 3rd Edition 2 year 330V DC Wiring Device-Kellems SCCR: Short Circuit Current Rating N-G 700 N/A HBL80MPC 60kA 120kA -10°F to 60°F (14°C to 140°C) Audible Alarm 3.63"H x 8.73"W — — Up tp -20dB 60 Hz 3R, 2 Meter Base, Non-Metallic — 10 year — L-L 1500 N/A † MCOV: Maximum Continuous Operating Voltage. ‡ In: Nominal discharge current
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Modify Date : 2011:05:02 11:57:55+05:30 Create Date : 2011:05:02 11:57:21+05:30 Creator : Adobe InDesign CS3 (5.0) Producer : Adobe PDF Library 8.0 Page Count : 2EXIF Metadata provided by EXIF.tools