Multi 9™ System Catalog
Catalog
0860CT0201 R11/14
2014
Class 860
CONTENTS
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page
Contents Line 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page x
Contents Line 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page x
Contents Line 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page x
Master Pages
CONTENTS
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
UL and CSA Rated Protection Devices . . . . . . . . . . . . . . . . . . . . . . . . . . .14
IEC 60947-2 Rated Protection Devices . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Ground-Fault Protection Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Additional System Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Time/Current Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85
Let-Through Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90
Index of Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97
™
© 2008–2014 Schneider Electric
All Rights Reserved
3
0860CT0201 R11/14 Multi 9™ System Catalog
Table of Contents
Table of Contents
SECTION 1: INTRODUCTION .............................................................. 7
Multi 9™ Products for Equipment Applications ........................................... 7
System Flexibility ................................................................................... 7
Advantages ........................................................................................... 8
Conformance to Standards ......................................................................... 9
Overview ............................................................................................... 9
UL 489/CSA C22.2 No.5 Standard–Branch Circuit Protection .............. 9
UL 1077 Standard—Supplementary Protection within the Product ..... 10
Comparing Terminology for UL 489/CSA C22.2 No.5 and
1077 Standards ................................................................................... 11
UL 486 Standard—Connection Terminals ........................................... 12
IEC 60947-2 Standard ......................................................................... 12
IEC 60898 Standard ............................................................................ 12
CSA C22.2 Standard ........................................................................... 12
CCC Mark ............................................................................................ 12
UL 508 Standard—Manual Motor Controllers ..................................... 12
SECTION 2: UL AND CSA RATED PROTECTION DEVICES ........... 14
UL 489/CSA C22.2 No.5 Listed 240 Vac C60 Circuit Breakers (AC) ....... 16
Standard Features ............................................................................... 16
Connections ........................................................................................ 17
Standards ............................................................................................ 17
Catalog Numbers ................................................................................ 18
UL 489/CSA C22.2 No. 5 Listed 480Y/277 Vac C60 Circuit
Breakers (AC) ........................................................................................... 19
Benefits ............................................................................................... 19
Standard Features ............................................................................... 19
Connections ........................................................................................ 20
Standards ............................................................................................ 20
Catalog Numbers ................................................................................ 20
UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers (DC) .................... 21
Overview ............................................................................................. 21
Catalog Numbers ................................................................................ 21
UL 1077 Recognized C60 Supplementary Protectors .............................. 22
Standards ............................................................................................ 22
Standard Features ............................................................................... 23
Catalog Numbers ................................................................................ 23
SECTION 3: IEC 60947-2 RATED PROTECTION DEVICES ............. 24
N40 Phase + Neutral Circuit Breakers ...................................................... 25
Time/Current Curves ........................................................................... 25
Accessories ......................................................................................... 25
Standards ............................................................................................ 25
Catalog Numbers ................................................................................ 26
IEC Rated C60 Miniature Circuit Breakers ............................................... 27
Standard Features ............................................................................... 27
Catalog Numbers ................................................................................ 28
Catalog Numbers ................................................................................ 28
Catalog Numbers ................................................................................ 29
IEC Rated C120H Circuit Breakers ........................................................... 30
Standard Features ............................................................................... 30
Accessories ......................................................................................... 31
Standards ............................................................................................ 31
Catalog Numbers ................................................................................ 31
™
Multi 9™ System Catalog
4
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
SECTION 4: GROUND-FAULT PROTECTION DEVICES .................. 32
Selection Table ......................................................................................... 32
UL 1053 Listed GFP Ground Fault Protectors ..........................................33
Standards ............................................................................................33
Catalog Numbers .................................................................................34
IEC Rated ID Residual Current Switches ..................................................35
Standards ............................................................................................36
Catalog Numbers .................................................................................36
IEC Rated C60 Vigi
TM
Modules for Ground-fault Protection .....................37
Accessories .........................................................................................38
Standards ............................................................................................38
Catalog Numbers .................................................................................38
IEC Rated C120 Vigi Residual Current Circuit Breakers ...........................39
Standards ............................................................................................39
Catalog Numbers .................................................................................39
N40 Vigi Residual Current Circuit Breaker ................................................ 40
Function ...............................................................................................40
Catalog Numbers .................................................................................40
Standards ............................................................................................40
SECTION 5: ACCESSORIES .............................................................. 41
Electrical Auxiliaries .................................................................................. 42
MN Undervoltage Release ..................................................................43
MX + OF Shunt Trip and Auxiliary Switch ........................................... 43
OF Auxiliary Switch .............................................................................44
OFS Auxiliary Switch and Adapter (for GFP and ID RCD) .................. 44
SD Alarm Switch .................................................................................. 44
Comb Bus Bars .........................................................................................45
UL Recognized C60 and N40 Comb Bus Bars ........................................ 45
Tooth Caps for UL Recognized Comb Bus Bars ................................. 45
Connection Comb Bus Bars for C60 UL 1077 Circuit Breakers .......... 46
Connection Comb Bus Bars for C60 UL489 Circuit Breakers ............. 47
IEC Rated C60 Comb Bus Bars .......................................................... 48
End Caps for IEC Rated C60 Comb Bus Bars ....................................49
Connector for IEC Rated Comb Bus Bars ........................................... 49
Tooth Caps for IEC Rated Comb Bus Bars ......................................... 49
Device Shielding ....................................................................................... 49
DIN Rail Spacer ................................................................................... 49
Terminal Screw Shields .......................................................................50
Terminal Covers .................................................................................. 50
Ring Lug Terminal Kit ..........................................................................50
Identification System ................................................................................. 51
Snap-on Marking Symbols ..................................................................51
Operation Devices .....................................................................................52
Rotary Handles .................................................................................... 52
Padlock Attachments ........................................................................... 52
Mounting Accessories ............................................................................... 54
Plug-in Base ........................................................................................54
Front Mounting Bracket (Kit) ................................................................ 54
DIN Rail Mounting Clips ......................................................................55
UL/CSA Recognized Mounting Base for Multi 9 C60 Circuit Breakers ..... 55
Mounting Base Accessories ................................................................ 56
Wire Lug Kit ................................................................................... 56
Multi-Pole Front Mounting Kit .............................................................. 57
Pole Filler ............................................................................................. 57
SECTION 6: ADDITIONAL SYSTEM DEVICES ................................. 58
™
Multi 9™ System Catalog
5
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
CM Selector Switches ......................................................................... 58
I Current Isolating Switch .................................................................... 60
Status, Display and Control Accessories .................................................. 61
V Signal Lamp ..................................................................................... 61
BP Push Buttons ................................................................................. 62
CH Hour Counter ................................................................................. 63
CI Impulse Counter ............................................................................. 63
Kaedra™ Weatherproof DIN Type Enclosures ......................................... 64
Applications ......................................................................................... 64
Standard Features ............................................................................... 64
Construction ........................................................................................ 64
Installation ........................................................................................... 64
Accessories ......................................................................................... 65
SECTION 7: DIMENSIONS ................................................................. 66
UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers ............................. 66
UL 1077 Supplementary Protectors .......................................................... 67
IEC Rated Circuit Breakers ...........................................................................67
UL and IEC Rated Ground-Fault Products ............................................... 68
Accessory Dimensions .............................................................................. 69
Kaedra Weatherproof Mini-Enclosure Dimensions ................................... 75
Kaedra Weatherproof Enclosures ............................................................. 76
SECTION 8: APPLICATIONS ............................................................. 78
Degree of Protection (IP) .......................................................................... 78
Vibration .............................................................................................. 79
Mechanical Shock (IK) ........................................................................ 79
Protection of 400 Hz Circuits ............................................................... 79
Temperature Rating .................................................................................. 80
Typical IEC Grounding Systems ............................................................... 83
Codification of the Grounding Systems ............................................... 83
The TT Grounded Neutral System ...................................................... 83
The IT Grounding System ................................................................... 84
The TN-S Grounding System .............................................................. 84
SECTION 9: TIME/CURRENT CURVES ............................................. 85
UL 489/CSA C22.2 No. 5 and UL 489A Listed C60 Miniature
Circuit Breakers ..................................................................................................85
UL 1077 Recognized Supplementary Protectors ...................................... 86
IEC60947-2 Rated D PN-N Circuit Breakers ............................................ 87
Alternative Current 50/60 Hz ..................................................................... 88
Motor Curve .............................................................................................. 89
SECTION 10: LET-THROUGH CURVES .............................................. 90
UL Listed C60 Miniature Circuit Breakers and UL Recognized C60
Supplementary Protectors ........................................................................ 90
Limitation curves ....................................................................................... 94
INDEX OF PART NUMBERS ................................................................... 97
™
Multi 9™ System Catalog
6
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
™
Multi 9™ System Catalog
Section 1—Introduction
7
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Section 1—Introduction
Multi 9™ Products for Equipment Applications
Multi 9 modular system of miniature circuit breakers and supplementary protectors, accessories, and
peripherals provides protection of equipment or especially sensitive circuits within the equipment.
Installation labor and space are both minimized by the modular architecture of the Multi 9 system,
whether a single protective device or multiple devices with their accessories are being used.
Schneider Electric offers an extensive line of UL 489/CSA C22.2 No.5 Circuit Breakers and UL 1077
Supplementary Protectors. In addition, a variety of IEC certified Circuit Breakers and Accessories are
available for an original equipment manufacturer (OEM) whose products are destined for export
beyond North America. To an OEM, this means that one family of electrical protection products can be
used regardless of equipment destination.
The Standards include:
Potential applications include semi-conductor machines, communication equipment, process control
panels, computers, medical equipment, electronic controls, transformers, power supplies, and other
electrical equipment.
System Flexibility
The Multi 9 System includes an extensive line of field-installable accessories. Plug-on electrical auxiliaries
include shunt trip, undervoltage release, auxiliary switch, and alarm switch. Other protection devices include
residual current devices, dc circuit breakers, and switches. Control and display devices include signal
lamps, push buttons, and motor operators. There are also mechanical accessories for locking, operating,
shielding, mounting, etc. The following diagram shows many of the Multi 9 system accessories.
• UL 489 Standard for Circuit Breakers
• UL 489A Standard for DC Communication Applications
• UL 1077 Standard for Supplementary Protectors
• UL 1053 Ground Fault Sensing and Relaying Equipment
• IEC 60947-2 Low-voltage switchgear and controlgear - Part
2: Circuit-breakers
• CSA C22.2 No. 5 Standard for Circuit Breakers
• CSA C22.2 No. 235 Supplementary Protectors
• CCC Pending
• C60 Miniature Circuit Breakers are RoHS Compliant
Figure 1: Functional Diagram of Multi 9 System
CI
Impulse
Counter
CH
Hour
Counter
V
Signal
Lamp
V
Signal
Lamp
BP
Push
Button
(N.O.)
or
Signal
BP
Push
Button
(N.C.)
or
Signal
TM
Motor
Operator
SD
Alarm
Switch
OF
Aux
Switch
MX + OF
Shunt
Trip
&
Aux
Switch
MN
Under-
voltage
Release
C60
Circuit
Breaker
Vigi or GFP
Residual
Current Device
IH
and
IHP
Time
Switches
I
Switch
CM
Selector
Switch
DPN-N
Residual
Current
Circuit
Breaker
OFS
&
Elect.
Accessory
GFP
Ground
Fault
Protector
Status and Display Output
Plug-on Electrical Auxiliaries
Other devices used with or instead of the C60 device
Protected Line
Control Inputs
Switch or
Control
Metering
Device
08603577
™
Multi 9™ System Catalog
Section 1—Introduction
8
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Advantages
Multi 9 C60 circuit breakers and supplementary protectors provide several features which are
important to OEMs. These include:
•
Small, compact size
•
Easy installation on DIN rails
•
Limits let-thru current
•
Resetability, more convenient than fuses
•
Electrical auxiliaries for control and status information
•
Extensive variety of accessories
Better Protection—Multi 9 supplementary protectors and miniature circuit breakers limit let-through
current, providing faster separation of the component from the fault, thereby reducing system damage.
More Selection—More ratings compatible with low-power electronic circuits are available in the range
from 0.5 to 10 A. Others are provided in convenient steps, up to 63 A for the C60 products.
Reduction of Nuisance Tripping—Available with different trip characteristics to meet system needs:
B, C and D curves, depending on the model.
Panel Space Savings—Multi 9 products are compact. Width per pole is only 0.71 in. (18 mm) for the
C60 circuit breaker. All of the products are built in a consistent format with incremental widths of 0.35
in. (9 mm) (therefore the name Multi 9).
Simple Installation—The Multi 9 products mount easily onto a 35 mm DIN mounting rail. Large box
lug terminals (pressure plate type) are suitable for use with copper wiring up to 2 AWG for C60 circuit
breakers and supplemental protectors.
Reverse Feeding— Reverse feeding of line power is permitted.
Reliability—Each C60 miniature circuit breaker has an endurance of 10,000 operation cycles and
voltage withstand of 6000 V impulse rating.
World-Wide Availability—The Multi 9 products are available and supported throughout the world by
Schneider Electric.
From the Power Distribution Specialists—Schneider Electric can be your single source of
protection equipment, with a comprehensive line of products for OEM products or the factory. In
addition to the Multi 9 circuit breakers and supplementary protectors, these products include the
following:
•
QO™ and QOU Miniature Circuit Breakers 10–125 A
•
Compact™ Molded Case Circuit Breakers 15–3200 A
•
Powerpact™ Molded Case Circuit Breakers 15–3000 A
•
Masterpact™ Universal Power Circuit Breakers 250–6300 A
Figure 2: UL 489/CSA C22.2 No. 5 Listed Multi 9 C60 Circuit Breakers
1P 3P2P
™
Multi 9™ System Catalog
Section 1—Introduction
9
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Conformance to Standards
Overview
Multi 9 circuit protection products conform to the standards most needed by OEMs—UL 489/CSA C22.2
No.5, UL 1077, CSA C22.2 No. 235, and IEC 60947-2.
Different applications call for circuit protection devices that meet different standards. The Multi 9 family
allows OEMs to use a single family of products in their equipment, whether it is destined for the United
States, Canada or an international market outside of North America. A variety of Multi 9 devices are tested
per Underwriters Laboratories
®
(UL
®
) and Canadian Standards Association
®
(CSA
®
) Standards as
required by the National Electrical Code
®
(NEC
®
) in the United States and the Canadian Electrical Code
(CEC) in Canada. They are also tested per the standards of the International Electrotechnical Commission
®
(IEC
®
) and may therefore be used in International Markets where these products meet the requirements.
In this catalog, the products are grouped by the standards they are designed to meet, including:
•
UL 489—Defines rigorous testing requirements for circuit breakers in the United States
•
CSA C22.2 No. 5—Defines rigorous testing requirements for circuit breakers in Canada
•
CSA C22.2 No. 235—Defines requirements for supplementary protectors
•
UL 489A—Limited applications (dc circuits in communications equipment)
•
UL 1077—Defines supplementary protectors for use within electrical equipment protected by
branch circuit breakers
•
IEC 60947-2—International standards for circuit breakers to be used in industrial applications
UL 489/CSA C22.2 No.5 Standard–Branch Circuit Protection
An OEM product as a whole must be appropriately protected from overcurrent conditions, either by
connection in the field to a protected branch circuit (in accordance with NEC) or by inclusion of branch
circuit protection within the product itself. In the United States, these branch circuit protection devices
must comply with the UL 489/CSA C22.2 No.5 Standard for Molded-Case Circuit Breakers. (see UL
489/CSA C22.2 No.5 No. 1 in Figure 3, which is a drawing of a hypothetical piece of OEM equipment
requiring multiple protection devices.)
Applications Requiring UL 489/CSA C22.2 No.5 Listed Circuit Breakers
In some instances, the protective devices being installed in equipment must comply with UL 489/CSA
C22.2 No.5. These include the following situations:
1. If a circuit such as a convenience receptacle could leave the equipment, that circuit must be
protected by a UL 489/CSA C22.2 No.5 branch circuit protection device (see UL 489/CSA C22.2
No.5 No. 2).
2. If a circuit such as to an external motor could leave the equipment, that circuit must be protected by
a UL 489/CSA C22.2 No.5 branch circuit protection device (see UL 489 No. 3).
3. Motors within the equipment should also be protected by a UL 489/CSA C22.2 No.5 device (see UL
489 No. 4).
4. All equipment which requires HACR (Heating, Air Conditioning, and Refrigeration) rating must be
protected by a UL 489/CSA C22.2 No.5 branch circuit protection device (see UL 489 No. 5).
NOTE: The motor control circuit may be protected by a UL 1077 device. It must also have over current
protection even though there is a UL 1077 device downstream.
In general, a UL 489/CSA C22.2 No.5 circuit breaker could also be used in any application for which a
UL 1077 device is allowed, since the UL 489/CSA C22.2 No.5 devices meet or exceed the
requirements of UL 1077 devices. The converse of this is not true, since UL 1077 devices cannot meet
the more stringent UL 489/CSA C22.2 No.5 Standard.
™
Multi 9™ System Catalog
Section 1—Introduction
10
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
UL 1077 Standard—Supplementary Protection within the Product
Within the OEM product itself, additional (supplementary) protection for sensitive or critical internal
circuitry may be provided by one or more supplementary circuit protectors. A supplementary protector
is an overcurrent protection device which is specifically designed for OEM applications and which
complies with UL 1077 Standard for Supplementary Protectors for Use in Electrical Equipment.
Under UL 1077, supplementary protectors may be used under the following conditions:
•
When branch overcurrent protection is already provided
•
If short-circuit protection is needed for sensitive devices within the equipment
•
When wiring connected to the supplementary protector does not exit the equipment to external
devices such as receptacles or motors
•
If the UL 1077 device does not provide the only means of disconnecting the product
The following applications illustrated in Figure 3 allow the use of UL 1077 supplementary protectors:
•
The supplementary protection is used to supplement or provide additional protection to sensitive
components inside the equipment (see UL 1077 No. 1). A UL 489/CSA C22.2 No.5 circuit breaker
must be located upstream from the equipment.
•
Critical or sensitive internal circuitry (see UL 1077 No. 2) such as: Computers and microprocessors,
communications equipment, electronic controllers, power supplies and many other types of equipment
•
Motor control circuits may be protected by a UL 1077 device, unless the circuit includes a
transformer (in which case a UL 489/CSA C22.2 No.5 device is required).
™
Multi 9™ System Catalog
Section 1—Introduction
11
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
NOTE: This is a simplified summary of the standards. Refer to applicable codes for specific applications.
Comparing Terminology for UL 489/CSA C22.2 No.5 and 1077 Standards
The terms used to differentiate these products can cause confusion if a user is not careful. Misapplying
the terms may result in misapplication of the products.
Any one of the following terms can be used to identify supplementary protectors:
Any of the following terms can be used to identify circuit breakers:
Figure 3: Guidelines for Application of UL 489/CSA C22.2 No.5 Circuit Breakers and UL 1077 Supplementary Protectors
1
2
3
4
5
1
1
2
3
2
3
2
1
3
5
4
Equipment Enclosure
Feeder or
Branch
Circuit UL 489/CSA C22.2 No.5 Listed Molded Case Circuit Breaker (MCCB)
or Miniature Circuit Breaker (MCB)
Protected by
Branch
Circuit Breaker
Electronics
Other
Sensitive
Devices
Miscellaneous
Devices
External
Motor
Internal
Motor
Motor
Control
HACR
UL 489
UL 489
UL 489
UL 1077
UL 1077
UL 1077
UL 489
Internal
Receptacle External
Receptacle
UL 1077
Applications Permitting Supplementary Protectors
Supplements or provides additional protection for
sensitive electronics inside the equipment.
Used on the load side of branch circuit protection to
protect critical or sensitive internal circuitry such as:
• Computers and microprocessors
• Communications equipment
• Electronic controllers
• Power supplies
• Many other types of equipment
Permitted for protection of motor control circuits
NEC 430-72, unless transformers are in circuit,
then UL 489/CSA C22.2 No.5.
UL 489/CSA C22.2 No.5
Applications Requiring Branch Circuit Protection
Protects conductors entering the OEM equipment.
This required UL 489/CSA C22.2 No.5 device may be
provided integral to the OEM equipment or be
external as part of the distribution system.
May act as branch circuit protection
if it protects the conductor to the utilization equipment.
Required to protect convenience receptacle circuits
(internal or external)
Required to protect an external load circuit leaving
the equipment
Required for motors in the equipment
Required for HACR equipment
(Heating, Air Conditioning, and Refrigeration)
08603335
•
Supplementary protector
•
UL Recognized
•
UL 1077
•
The UL symbol
•
Circuit breaker
•
UL Listed
•
UL 489/CSA C22.2 No.5
•
The UL symbol
™
Multi 9™ System Catalog
Section 1—Introduction
12
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
UL 486 Standard—Connection Terminals
The UL 486 Standard applies to compression wiring connection terminals. It is a requirement for
connections of a UL 489/CSA C22.2 No.5 circuit breaker. Although it is not a requirement for UL 1077
Recognized devices, UL 486 Rated terminals are included on those Multi 9 products. This allows the
user to apply field wiring directly to any of these devices, without using intermediate, UL rated terminal
blocks.
The connectors on Multi 9 devices are Rated UL 486A-B, which applies to copper conductors.
These standards apply to field-wired terminals that are an integral part of the equipment. Criteria
includes static heating tests, secureness tests, and pull-out tests.
IEC 60947-2 Standard
In countries which follow the IEC Standards, IEC 60947-2 is used for most industrial applications of
circuit protection. IEC 60947-2 does not distinguish between the two levels of protection equivalent to
UL 489/CSA C22.2 No.5 circuit breakers and 1077 supplementary protectors. Therefore, in equipment
like that illustrated in figure 3, if IEC guidelines apply, then all of the devices could be selected from the
IEC Rated portion of this catalog.
IEC 60898 Standard
The IEC 60898 Standard is less stringent than 60947-2. It applies primarily to residential applications
of circuit breakers in countries adhering to IEC Standards, and is not generally applicable to OEMs.
CSA C22.2 Standard
The CSA (Canadian Standards Association) C22.2 Standards closely correspond to the UL Standards:
CSA C22.2 No. 5-02 (harmonized to UL 489/CSA C22.2 No.5) and CSA C22.2 No. 235 (equivalent to
UL 1077). All UL rated devices also have the corresponding CSA rating, unless otherwise noted.
CCC Mark
The China Compulsory Certification (CCC) mark is a new safety and quality mark system. Compulsory
Product Certification System (CPCS) prohibits the sale or importation of equipment under the scope of
the law that does not bear the CCC Mark issued by a Designated Certification Body (DCB). The CCC
Mark covers both safety and Electromagnetic compatibility.
The CPCS regulates twenty-two different product groups, which include the following:
Electrical wires and cables; switches for circuits, installation protective and connection devices; low-
voltage electrical apparatus; small power motors; electric tools; welding machines; household and
similar electrical appliances; audio and video apparatus; information technology equipment; lighting
apparatus; telecommunications terminal equipment; motor vehicles and safety parts; motor vehicle
tires; safety glass; agricultural machinery; latex products; medical devices; fire fighting equipment;
detectors for intruder alarm systems; wireless local area network equipment; security and protection
equipment; and decoration and renovation products.
UL 508 Standard—Manual Motor Controllers
UL Standard 508 covers industrial control equipment, specifically for motor control functions. It covers
individual devices as well as assemblies.
There are UL 508 Listed manual motor controllers that look much like miniature circuit breakers, and
have thermal settings and instantaneous settings similar to circuit breakers. These are specialized
devices and cannot be used for a wide range of applications, as can UL 1077 and UL 489/CSA C22.2
No.5 devices.
Like UL 1077 supplementary protectors, a UL 508 Listed manual motor controller (or a group of them)
must be protected by a UL 489/CSA C22.2 No.5 Listed branch circuit breaker.
CCC Mark
™
Multi 9™ System Catalog
Section 1—Introduction
13
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Manual motor controllers are available from Schneider Electric (Telemecanique products GV2 and
GV3) but are not included in this catalog.
Table 1: Comparison Summary of Applicable UL and IEC Standards
Characteristic UL 489/CSA C22.2 No. 5 UL 1077/CSA C22.2 No. 235 IEC 60947-2
Labeling UL Listed UL Recognized component IEC Certified device
Nomenclature Circuit breakers Supplementary protectors Circuit breakers or supplementary protectors
Dielectric test (for 240
Vac)
2 times rated plus 1000 V for 1 minute
(1,480 at 240 Vac)
2 times rated plus 1,000 V for 1 minute
(1,480 at 240 Vac) 1,500 V
Interrupting rating 10 kA at 240 Vac 10 kA at 240 Vac 20 kA at 240 Vac
Overload protection 50 operations at 600% rating 50 operations at 150% rating 12 operations at 600% rating
Service capacity Must be operational after two interruptions
May be tested in series with branch circuit
device and may become inoperable after
test
Must be operational after two interruptions
Calibration test 200% In, 2 minutes max. (0–30 A) Per manufacturer’s trip curve At 200% In, time shall not exceed
manufacturer’s stated value
Calibration temperature 25°C (77°F), unless other value specified by
manufacturer Manufacturer must specify Manufacturer must specify
Testing temperature 25°C (77°F) ambient, 50°C (122°F) rise max.
at terminals
25°C (77°F) ambient, 50°C (122°F) rise max.
at field wiring terminals; 65°C (149°F) rise
max. on factory wiring terminals
At 25°C (77°F) ambient, 80°C (176°F) rise
max. at terminals
Endurance
6000 operations at rated current and
voltage, 75-80% PF, plus 4000 operations at
no load
6000 operations at rated current and
voltage, 75-80% PF
1500 operations at rated current and
voltage, 75-80% PF
Air spacing 3/4 in. (20.1 mm) 3/8 in. (9.53 mm) See dielectric
Surface spacing 1-1/4 in. (31.8 mm) 1/2 in. (12.7 mm) See dielectric
Test and follow up tests Initial, periodic and quarterly follow-up tests
observed by UL representative
Initial tests observed by UL representative,
plus quarterly visual follow-up inspection by
UL
Conducted by manufacturer
™
Multi 9™ System Catalog
Section 2—UL and CSA Rated Protection Devices
14
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Section 2—UL and CSA Rated Protection Devices
The Multi 9 system includes several families of miniature circuit protection devices that have the UL
ratings required in the United States and some other countries. The products are summarized below
and are described in detail on the following pages. They include the following families:
•
UL Listed C60 240 V Circuit Breakers (UL 489/CSA C22.2 No.5)
•
UL Listed C60 480 V Circuit Breakers (UL 489/CSA C22.2 No.5)
•
UL Listed C60 Circuit Breakers for use in Communication Equipment (UL 489A) not CSA certified
•
UL Recognized C60 Supplementary Protectors (UL 1077 and CSA C22.2 No. 235)
NOTE: Protection devices with only IEC ratings are described in Section 3, while accessories for both
the UL and IEC devices are described in Section 5.
Table 2: Specifications for UL 489/CSA C22.2 No.5 Circuit Breakers
Ratings per UL Standards UL 489/CSA C22.2 No.5 C60
(240 Vac)
UL 489/CSA C22.2 No.5 C60
(480Y/277 Vac)
Number of Poles 1P 2P 3P 1P 2P 3P
Rated Current at 77°F (25°C) 0.5–20 A 25–35 A 0.5–35 A 0.5–35 A 0.5–20 A 1–20 A 1–20 A
Interrupting Ratings
as per UL 489/CSA C22.2 No.5
AC 50/60 Hz
120 V
240 V
277 V
480Y/277 V
10 kA
10 kA
—
—
10 kA
5 kA
—
—
—
10 kA
—
—
—
10 kA
—
—
10 kA
10 kA
10 kA
—
—
10 kA
10 kA
10 kA
—
10 kA
10 kA
10 kA
DC 60 V
125 V
10 kA
—
10 kA
10 kA
—
—
—
—
—
—
—
—
Ultimate Breaking Capacity (Icu)
as per IEC 60947-2 AC 50/60 Hz
240 V
415 V
440 V
10 kA
10 kA
—
20 kA
10 kA
6 kA
20 kA
10 kA
6 kA
10 kA
10 kA
—
10 kA
10 kA
6 kA
10 kA
10 kA
6 kA
Service Breaking Capacity (Ics) (%Icu) 75% 75% 75% 75% 75% 75% 75%
Magnetic Setting (Times
Ampere Rating)
B curve
C curve
D curve
—
7 to 10
10 to 14
—
7 to 10
10 to 14
Dimensions (in./mm)
Width 0.71/18 0.71/18 1.42/36 2.13/54 0.71/18 1.42/36 2.13/54
Height box/box
ring/ring1
4.21/107
4.86/123.4
4.21/107
4.86/123.4
4.21/107
4.86/123.4
4.21/107
4.86/123.4
5.56/141
5.56/141
5.56/141
5.56/141
5.56/141
5.56/141
Depth 3.00/76 3.00/76 3.00/76 3.00/76 3.00/76 3.00/76 3.00/76
Weight (oz./g) max. box/box
ring/ring
4.4/136
5.2/161
4.4/136
5.2/161
8.7/271
10.3/321
13.1/407
15.5/482
5.3 (166)
5.3 (166)
10.6/332
10.6/332
15.9 (498)
15.9 (498)
1Fingersafe 240 V C60 circuit breaker ring terminal dimensions are same as the 480 V C60 circuit breaker.
™
Multi 9™ System Catalog
Section 2—UL and CSA Rated Protection Devices
15
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Figure 4: UL 1077 Recognized C60 Supplementary Protectors
Table 3: Specifications for UL 1077 Recognized Supplementary Protectors
Ratings per UL Standards UL 1077 C60
Number of Poles 1P 2P 3P 4P
Rated Current at 77°F (25°C) 0.5–63 A 0.5–63 A 0.5–63 A 0.5–63 A
Interrupting Ratings
as per UL 1077
50/60 Hz
120 Vac
240 Vac
277 Vac
480Y/277 Vac
10 kA
10 kA
5 kA
—
—
10 kA
—
5 kA
—
10 kA
—
5 kA
—
10 kA
—
5 kA
—65 Vdc
125 Vdc
10 kA
—
—
10 kA
—
—
—
—
Ultimate Breaking
Capacity (Icu) as per
IEC 60947-2
50/60 Hz
240 Vac
415 Vac
440 Vac
10 kA
3 kA
—
20 kA
10 kA
6 kA
20 kA
10 kA
6 kA
20 kA
10 kA
6 kA
Service Breaking Capacity (Ics) (%Icu) 75% 75% 75% 75%
Plug-On Auxiliary Modules with Mechanical Linkage:
MN Undervoltage Trip
MX + OF Shunt Trip/Auxiliary Switch
OF Auxiliary Switch
SD Alarm Switch
Magnetic Setting
B Curve
C Curve
D Curve
Between 3.2 and 4.8 Times Ampere Rating
Between 7 and 10 Times Ampere Rating (Between 7 and 14 for dc)
Between 10 and 14 Times Ampere Rating (No DC Rating for D Curve)
Dimensions (in./mm)
Width
Height
Depth
0.71/18
3.19/81
3.00/76
1.42/36
3.19/81
3.00/76
2.13/54
3.19/81
3.00/76
2.84/72
3.19/81
3.00/76
Weight (oz./g) 3.85/110 7.70/220 11.55/330 15.40/440
1P 2P 4P3P
™
Multi 9™ System Catalog
Section 2—UL and CSA Rated Protection Devices
16
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
UL 489/CSA C22.2 No.5 Listed 240 Vac C60 Circuit Breakers (AC)
A selected range of Multi 9 circuit breakers rated 240 V are UL 489/CSA C22.2 No.5 Listed. Unlike UL
1077 Supplementary Protectors, these UL 489/CSA C22.2 No.5 circuit breakers can be used for
branch circuit protection as required by the National Electrical Code.
As shown in tables 5 and 6 the UL 489/CSA C22.2 No.5 Listed products are available in
C and D curves. They include devices ranging from 0.5 to 35 A.
Standard Features
•
Fast closing: Allows increased withstand to the high inrush currents of some loads.
•
Trip-free mechanism: Contacts cannot be held in the I-ON position when the C60 circuit breaker is
tripped automatically.
•
Positive indication of contact disconnect. Green mechanical indication on front face of circuit
breaker shows that all poles are open.
•
C curve: Overcurrent protection for all application types. Magnetic release operates from 7 to 10
times ampere rating (7 to 14 for DC applications).
Figure 5: UL 489/CSA C22.2 No.5 Listed Multi 9 C60 Circuit Breakers
Table 4: Specifications for UL 489/CSA C22.2 No.5 240 V Listed C60 Circuit Breakers
High Voltage Withstand 6 kV
Connector: Box Lug
Rating UL 486A File No. E216919 (Use with Copper Wire Only)
Connection
0.5–25 A: 14–4 AWG (2–25 mm2) Cables
Torque to 22 lb-in. (2.48 N•m)
30–35 A: 14–2 AWG (1–35 mm2) Cables
Torque to 31 lb-in. (3.52 N•m)
Connector: Ring Tongue
Use Single UL Listed or CSA Certified
Insulated Ring Tongue Only
Screw dia. 0.2 in. (5 mm)
Torque to 18 lb-in. (2.03 N•m)
Max Ring Terminal Width 0.54 in. (14 mm)
Mounting 35 mm DIN rail
Degree of Protection Case IP40 as per IEC 529
Terminals IP20
Temperatures
Calibration
Storage
Operating
25°C (77°F)
-40 to 80°C (-40 to 176°F)
-30 to 70°C (-22 to 158°F)
Plug-On Auxiliary Modules with
Mechanical Linkage:
MN Undervoltage Trip
MX + OF Shunt Trip/Auxiliary Switch
OF Auxiliary Switch
SD Alarm Switch
Tropicalization Treatment 2 Relative Humidity: 95% at 131°F (55°C)
Number of Operating Cycles Electrical (O-C) 6,000 load, 4,000 no-load
See specifications Table 2 on page 14 for dimensions, weights and interrupting ratings
1P 2P 3P
™
Multi 9™ System Catalog
Section 2—UL and CSA Rated Protection Devices
17
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
•
D curve: Overcurrent protection for loads with high inrush currents (motors, transformers).
Magnetic release operates between 10 and 14 times ampere rating (no dc rating for D curve).
•
Suitable for reverse feeding.
•
Allows locking in O-OFF position using padlock attachment.
Connections
Three versions of field wiring connectors are available for the 240 Vac UL 489/CSA C22.2 No.5 Listed
devices:
•
Box lug, meeting UL 486A requirements
•
Ring tongue terminal with 5 mm screw
•
Ring Tongue terminals with Fingersafe (IP20) shrouds
The circuit breakers can be ordered with the following combinations of connectors:
•
Line terminal box lug/load terminal box lug
•
Line terminal ring tongue/load terminal ring tongue (for fingersafe version, add -F suffix to catalog
number)
Standards
•
UL 489 Circuit Breaker: File No. E215117
•
Single-pole 15–20 A is UL Listed as SWD (switching duty).
•
1-, 2-, and 3-pole 15–35 A are HID (high intensity discharge) rated.
•
CSA C22.2 No. 5.1 Circuit Breakers: File No. 179014
•
IEC 60947-2
•
CE Marked
Figure 6: Connection Options for 240 Vac UL 489/CSA C22.2 No.5 Listed Devices
Box Lug
Box Lug
Ring
Tongue
Ring
Tongue
Fingersafe
Ring
Tongue
Fingersafe
Ring
Tongue
™
Multi 9™ System Catalog
Section 2—UL and CSA Rated Protection Devices
18
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Catalog Numbers
NOTE: UL 489/CSA C22.2 No.5 Listed Multi 9 circuit breakers are calibrated at 25°C (77°F). Please
refer to the rating tables (page 81) for applications at temperatures greater than 25°C (77°F).
NOTE: The NEC requires that the continuous load applied to the circuit breaker shall not exceed 80%
of the circuit breaker ampere rating.
Table 5: Catalog Numbers for C Curve, UL 489/CSA C22.2 No.5 Listed 240 Vac C60
Miniature Circuit Breakers (Box Lug and Ring Tongue Terminal Combinations)
Rating 1P 2P 3P
Box/Box Ring/Ring
1
1IP-20 Fingersafe ring tongue terminals may be ordered with an F suffix (example: 60210F).
Box/Box Ring/Ring
1
Box/Box Ring/Ring
1
0.5 A
1 A
1.5 A
60100
60101
60102
60200
60201
60202
60134
60135
60136
60234
60235
60236
—
60168
60169
—
60268
60269
2 A
3 A
4 A
60103
60104
60105
60203
60204
60205
60137
60138
60139
60237
60238
60239
60170
60171
60172
60270
60271
60272
5 A
6 A
7 A
60106
60107
60108
60206
60207
60208
60140
60141
60142
60240
60241
60242
60173
60174
60175
60273
60274
60275
8 A
10 A
13 A
60109
60110
60111
60209
60210
60211
60143
60144
60145
60243
60244
60245
60176
60177
60178
60276
60277
60278
15 A
20 A
25 A
60112
60113
60114
60212
60213
60214
60146
60147
60148
60246
60247
60248
60179
60180
60181
60279
60280
60281
30 A
35 A
60115
60116
60215
60216
60149
60150
60249
60250
60182
60183
60282
60283
Table 6: Catalog Numbers for D Curve, UL 489/CSA C22.2 No.5 Listed 240 Vac C60
Miniature Circuit Breakers (Line/Load as Box Lug or Ring Tongue Terminals)
Rating 1P 2P 3P
Box/Box Ring/Ring
1
1IP-20 Fingersafe ring tongue terminals may be ordered with an F suffix (example: 60210F).
Box/Box Ring/Ring
1
Box/Box Ring/Ring
1
0.5 A
1 A
1.5 A
60117
60118
60119
60217
60218
60219
60151
60152
60153
60251
60252
60253
—
60184
60185
—
60284
60285
2 A
3 A
4 A
60120
60121
60122
60220
60221
60222
60154
60155
60156
60254
60255
60256
60186
60187
60188
60286
60287
60288
5 A
6 A
7 A
60123
60124
60125
60223
60224
60225
60157
60158
60159
60257
60258
60259
60189
60190
60191
60289
60290
60291
8 A
10 A
13 A
60126
60127
60128
60226
60227
60228
60160
60161
60162
60260
60261
60262
60192
60193
60194
60292
60293
60294
15 A
20 A
25 A
60129
60130
60131
60229
60230
60231
60163
60164
60165
60263
60264
60265
60195
60196
60197
60295
60296
60297
30 A
35 A
60132
60133
60232
60233
60166
60167
60266
60267
60198
60199
60298
60299
™
Multi 9™ System Catalog
Section 2—UL and CSA Rated Protection Devices
19
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
UL 489/CSA C22.2 No. 5 Listed 480Y/277 Vac C60 Circuit
Breakers (AC)
The UL 489/CSA C22.2 No.5 Listed 480Y/277 Vac Multi 9 C60 miniature circuit breakers can be used
in 480Y/277 Vac systems. With amperages from 0.5 A to 20 A, they are ideal for fuse replacement, yet
carry the UL 489/CSA C22.2 No.5 Listing that is required for branch circuit applications. See
specifications in Table 2 on page 14 for dimensions, weights, and interrupting ratings.
Benefits
•
Satisfies customer’s preferences to use circuit breakers instead of fuses.
•
Eliminates costs of spare fuses, blown fuse indicators, additional wiring, etc.
•
Reduces concerns and uncertainty of misapplying a UL 1077 supplementary protector where a
UL 489 branch circuit breaker is required.
•
Facilitates one common design for UL 489/CSA C22.2 No.5, CSA and IEC applications.
•
Simplifies installation with a compact, DIN-mounted circuit breaker that accepts a wide range of
accessories.
•
Offers alternative terminations for ring terminals or cable.
Standard Features
•
Fast closing: Allows increased withstand to the high inrush currents of some loads.
•
Trip-free mechanism: Contacts cannot be held in the I-ON position when the circuit breaker is
tripped automatically.
•
Positive indication of contact disconnect. Green mechanical indication on front face of device
shows that all poles are open.
•
C curve: Overcurrent protection for all application types. Magnetic release operates from 7 to 10
times ampere rating. (7 to 14 for dc)
•
D curve: Overcurrent protection for loads with high inrush currents (motors, transformers).
Magnetic release operates between 10 and 14 times ampere rating (no dc rating for D curve).
•
Suitable for reverse feeding
•
Allows locking in O-OFF position using padlock attachment.
Table 7: Specifications for UL 489/CSA C22.2 No.5 Listed 480Y/277 Vac C60 Circuit
Breakers
Interruption Rating 2P and 3P
1P
480Y/277 V @ 10kA
277 Vac @ 10kA
Amperage 0.5 A through 20 A
Construction 1P, 2P and 3P
Magnetic Trip Curves C-curve
D-curve
7 to 10 Times Ampere Rating
10 to 14 Times Ampere Rating
UL 486E Listed Lug 18–16 AWG (1–1.5 mm2), Cu Only Stranded Wire:
14–10 AWG (2–5 mm2), Cu Only Solid or Stranded Wire
Torque to 7 lb-in (0.68 N•m)
Torque to 14 lb-in (1.6 N•m)
Ring Tongue Screw 5 mm Torque to 18 lb-in (2 N•m)
Plug-On Auxiliary Modules With
Mechanical Linkage:
MN Undervoltage Trip
MX + OF Shunt Trip/Auxiliary Switch
OF Auxiliary Switch
SD Alarm Switch
Mounting 35 mm DIN Rail
See selection Table 2 on page 14 for dimensions, weights, and interrupting ratings.
™
Multi 9™ System Catalog
Section 2—UL and CSA Rated Protection Devices
20
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Connections
Two versions of field wiring connectors are available:
•
Single-barrel lug with binding screws for two 18–10 AWG wires.
•
Crimp-type ring tongue terminal for up to 8 AWG wire.
Both of these terminals provide fingersafe ingress protection per IP20 of IEC EN60529. This feature
reduces the potential of incidental contact with live circuit breaker components.
Standards
•
UL 489/CSA C22.2 No.5 Listed
•
IEC 60947-2
•
CE Marked
Catalog Numbers
Table 8: Catalog Numbers for UL 489/CSA C22.2 No.5 Listed 480Y/277 V C60 Miniature
Circuit Breakers (AC)
Rating
Single Barrel Wire Lug Ring-Tongue Terminal
1P 2P 3P 1P 2P 3P
C-curve, 7–10 Times Ampere Rating
0.5 A
1 A
2 A
MGN61300
MGN61301
MGN61302
—
MGN61312
MGN61313
—
MGN61323
MGN61324
MGN61366
MGN61367
MGN61368
—
MGN61378
MGN61379
—
MGN61389
MGN61390
3 A
4 A
5 A
MGN61303
MGN61304
MGN61305
MGN61314
MGN61315
MGN61316
MGN61325
MGN61326
MGN61327
MGN61369
MGN61370
MGN61371
MGN61380
MGN61381
MGN61382
MGN61391
MGN61392
MGN61393
6 A
8 A
10 A
MGN61306
MGN61307
MGN61308
MGN61317
MGN61318
MGN61319
MGN61328
MGN61329
MGN61330
MGN61372
MGN61373
MGN61374
MGN61383
MGN61384
MGN61385
MGN61394
MGN61395
MGN61396
15 A
20 A
MGN61309
MGN61310
MGN61320
MGN61321
MGN61331
MGN61332
MGN61375
MGN61376
MGN61386
MGN61387
MGN61397
MGN61398
D-curve, 10–14 Times Ampere Rating
0.5 A
1 A
2 A
MGN61333
MGN61334
MGN61335
—
MGN61345
MGN61346
—
MGN61356
MGN61357
MGN61399
MGN61400
MGN61401
—
MGN61411
MGN61412
—
MGN61422
MGN61423
3 A
4 A
5 A
MGN61336
MGN61337
MGN61338
MGN61347
MGN61348
MGN61349
MGN61358
MGN61359
MGN61360
MGN61402
MGN61403
MGN61404
MGN61413
MGN61414
MGN61415
MGN61424
MGN61425
MGN61426
6 A
8 A
10 A
MGN61339
MGN61340
MGN61341
MGN61350
MGN61351
MGN61352
MGN61361
MGN61362
MGN61363
MGN61405
MGN61406
MGN61407
MGN61416
MGN61417
MGN61418
MGN61427
MGN61428
MGN61429
15 A
20 A
MGN61342
MGN61343
MGN61353
MGN61354
MGN61364
MGN61365
MGN61408
MGN61409
MGN61419
MGN61420
MGN61430
MGN61431
™
Multi 9™ System Catalog
Section 2—UL and CSA Rated Protection Devices
21
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers (DC)
Overview
A portion of the range of UL 489/CSA C22.2 No.5 circuit breakers are also Listed by UL for use with dc
circuits. The specifications are the same as the UL 489/CSA C22.2 No.5 circuit breakers, with the
following exceptions:
•
Number of poles: 1 and 2
•
Time/current curve: C curve
•
Magnetic setting of C curve: between 7 and 14 times ampere rating
•
DC voltage (nominal): 1 pole—60 Vdc, 2 pole—125 Vdc
•
Connection: box lug, ring/ring only (same torque)
Catalog Numbers
Table 9: Specifications for UL 489/CSA C22.2 No.5 C60 DC Circuit Breakers
Ratings per UL Standards UL 489/CSA C22.2 No.5 C60 (DC)
Number of Poles 1 2
Rated Current (A) at 77°F (25°C) 60 Vdc
Interrupting Ratings per UL 489/CSA C22.2 No.5
(kA)
60 Vdc 10 —
125 Vdc — 10
Service Breaking Capacity (Ics) (%Icu) 75% 75%
Magnetic Setting (Times Ampere Rating)
B curve — —
C Curve 7 to 14 7 to 14
D Curve — —
Dimensions
Width 0.71 in. (18 mm) 1.42 in. (36 mm)
Height (Box/Box) 4.21 in. (107 mm) 4.21 in. (107 mm)
Depth 3.00 in. (76 mm) —
Weight (Max.) 4.4 oz. (136 g) 8.7 oz. (271 g)
Load
4
1
2
12 in. Min.
–
+
3
08603438
2-Pole Wiring
Diagram
Table 10: Catalog Numbers for UL 489/CSA C22.2 No.5 C60 Listed Miniature Circuit Breakers
(DC)
1
1The dc catalog numbers are the same as the UL 489/CSA C22.2 No.5 ac equivalents.
Rating
C Curve
Rating
C Curve
1P,
Box/Box Ring/Ring 2P,
Box/Box Ring/Ring 1P,
Box/Box Ring/Ring 2P,
Box/Box Ring/Ring
0.5 A
1 A
60100
60101
60200
60201
60134
60135
60234
60235
10 A
13 A
60110
60111
60210
60211
60144
60145
60244
60245
1.5 A
2 A
60102
60103
60202
60203
60136
60137
60236
60237
15 A
20 A
60112
60113
60212
60213
60146
60147
60246
60247
3 A
4 A
60104
60105
60204
60205
60138
60139
60238
60239
25 A
30 A
60114
60115
60214
60215
60148
60149
60248
60249
5 A
6 A
60106
60107
60206
60207
60140
60141
60240
60241
35 A
40 A
60116
—
60216
—
60150
—
60250
—
7 A
8 A
60108
60109
60208
60209
60142
60143
60242
60243
50 A
63 A
—
—
—
—
—
—
—
—
™
Multi 9™ System Catalog
Section 2—UL and CSA Rated Protection Devices
22
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
UL 1077 Recognized C60 Supplementary Protectors
The UL 1077 products are intended for use as supplementary protectors to provide overcurrent
protection within appliances or electrical equipment where branch circuit protection is already provided
or is not required.
As shown in the table of catalog numbers below, the UL 1077 Recognized products are available in B,
C and D curves. They include devices ranging from 0.5 A to 63 A.
Standards
•
UL 1077 Circuit Breaker, File No. E90509
•
CSA C22.2 No. 235 File No. 179014
•
IEC 60947-2
•
CE Marked
Figure 7: UL 1077 Recognized C60N Supplementary Protectors
Table 11: Specifications for UL 1077 Recognized C60 Supplementary Protectors
Package Size 0.71 in. (18 mm) Width per Pole
Voltage Nominal Voltage
High Voltage Withstand
480Y/277 Vac
6 kV
Connection, Box Lug
UL 486A File No. E90509 Pending
Cable: 0.5–25 A: 14–4 AWG (2–25 mm2) Cu Only Torque 22 lb-in (2.49 N•m)
Cable: 30–63 A: 14–2 AWG (2–35 mm2) Cu Only Torque 31 lb-in (3.50 N•m)
Optional Ring Terminal Kit Screw Dia.: 0.2 in. (5mm) Torque 18 lb-in (2.03 N•m)
Mounting 35 mm DIN rail
Time-Current Curves B, C, and D Curves
Degree of Protection as per
IEC 68-2-30
Case IP40 as per IEC 529
Terminals IP20
Temperatures
Calibration 25°C (77°F)
Storage -40 to 80°C (-40 to 176°F)
Operating -30 to 70°C (-22 to 158°F)
Tropicalization Treatment 2 Relative Humidity: 95% at 131°F (55°C)
Number of Operating Cycles: Electrical (O-C) 10,000 at 0.5–63 A
See Specification Table 3 on page 15 for dimensions, weights and interrupting ratings.
1P 2P 3P 4P
™
Multi 9™ System Catalog
Section 2—UL and CSA Rated Protection Devices
23
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Standard Features
•
Trip-free mechanism: Contacts cannot be held in the on position when the C60 is tripped automatically.
•
Positive indication of contact disconnect. Green mechanical indication on front face of device
shows that all poles are open.
•
B curve: Overcurrent protection for sensitive equipment (computers, electronic devices, etc.).
Magnetic release operates between 3.2 and 4.8 (between 3.2 and 6.8 for dc).
•
C curve: Overcurrent protection for all application types. Magnetic release operates from 7 to 10
times ampere rating (between 7 and 14 for dc).
•
D curve: Overcurrent protection for loads with high inrush currents (motors, transformers).
Magnetic release operates between 10 and 14 times ampere rating (no dc rating).
•
Allows locking in O-OFF position using padlock attachment.
•
Suitable for reverse feeding.
For rating and dimensional information, see Table 3 on page 15, Specifications for UL 1077
Recognized Supplementary Protectors.
Catalog Numbers
Table 12: Catalog Numbers for UL 1077 Recognized C60 Supplementary Protectors
Rating
B Curve C Curve D Curve
1P 2P 3P 4P 1P 2P 3P 4P 1P 2P 3P 4P
0.5 A
1 A
1.2 A
1.5 A
—
MG24110
MG17402
MG17403
—
MG24125
MG17432
MG17433
—
MG24140
—
—
—
MG24155
—
—
MG17411
MG24425
MG17412
MG17413
—
MG24442
MG17442
MG17443
—
MG24459
—
—
—
MG24476
—
—
MG17421
MG24500
MG17422
MG17423
—
MG24516
MG17452
MG17453
—
MG24532
—
—
—
MG24548
—
—
2 A
3 A
4 A
5 A
MG24111
MG24112
MG24113
MG17404
MG24126
MG24127
MG24128
MG17434
MG24141
MG24142
MG24143
—
MG24156
MG24157
MG24158
—
MG24426
MG24427
MG24428
MG17414
MG24443
MG24444
MG24445
MG17444
MG24460
MG24461
MG24462
—
MG24477
MG24478
MG24479
—
MG24501
MG24502
MG24503
MG17424
MG24517
MG24518
MG24519
MG17454
MG24533
MG24534
MG24535
—
MG24549
MG24550
MG24551
—
6 A
7 A
8 A
10 A
MG24114
MG17405
MG24115
MG24116
MG24129
MG17435
MG24130
MG24131
MG24144
—
MG24145
MG24146
MG24159
—
MG24160
MG24161
MG24430
MG17415
MG24431
MG24432
MG24447
MG17445
MG24448
MG24449
MG24464
—
MG24465
MG24466
MG24481
—
MG24482
MG24483
MG24504
MG17425
MG24505
MG24506
MG24520
MG17455
MG24521
MG24522
MG24536
—
MG24537
MG24538
MG24552
—
MG24553
MG24554
13 A
15 A
16 A
20 A
MG24117
MG17406
MG24118
MG24119
MG24132
MG17436
MG24133
MG24134
MG24147
MG17461
MG24148
MG24149
MG24162
—
MG24163
MG24164
MG24433
MG17416
MG24434
MG24435
MG24450
MG17446
MG24451
MG24452
MG24467
MG17466
MG24468
MG24469
MG24484
—
MG24485
MG24486
MG24507
MG17426
MG24508
MG24509
MG24523
MG17456
MG24524
MG24525
MG24539
MG17471
MG24540
MG24541
MG24555
—
MG24556
MG24557
25 A
30 A
32 A
35 A
MG24120
MG17407
MG24121
MG17408
MG24135
MG17437
MG24136
MG17438
MG24150
MG17462
MG24151
MG17463
MG24165
—
MG24166
—
MG24436
MG17417
MG24437
MG17418
MG24453
MG17447
MG24454
MG17448
MG24470
MG17467
MG24471
MG17468
MG24487
—
MG24488
—
MG24510
MG17427
MG24511
MG17428
MG24526
MG17457
MG24527
MG17458
MG24542
MG17472
MG24543
MG17473
MG24558
—
MG24559
—
40 A
50 A
60 A
63 A
MG24122
MG24123
MG17409
MG24124
MG24137
MG24138
MG17439
MG24139
MG24152
MG24153
MG17464
MG24154
MG24167
MG24168
—
MG24169
MG24438
MG24439
MG17419
MG24440
MG24455
MG24456
MG17449
MG24457
MG24472
MG24473
MG17469
MG24474
MG24489
MG24490
—
MG24491
MG24512
MG24513
MG17429
MG24514
MG24528
MG24529
MG17459
MG24530
MG24544
MG24545
MG17474
MG24546
MG24560
MG24561
—
MG24562
™
Multi 9™ System Catalog
Section 3—IEC 60947-2 Rated Protection Devices
24
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Section 3—IEC 60947-2 Rated Protection Devices
The Multi 9 system includes several families of miniature circuit protection devices that have the IEC
ratings that are applicable in many countries other than the United States. These products are
summarized below and discussed in more detail in the following pages. UL Listed and UL Recognized
protection devices are described in Section 2, while accessories for both UL Listed and IEC Certified
products are described in Section 5.
Table 13: Specifications for IEC Rated Miniature Circuit Breakers
Ratings per IEC 60947-2 N40 C60N C60H C60L C120H
Number of Poles 1 (Ø + N) 1 2, 3, 4 1 2, 3, 4 1 2, 3, 4 1 2, 3, 4
Rated Current 25°C (77°F) In1–40 A 1–63 A 1–63 A 1–40 A 1–40 A 1–25 A 1–25 A — —
Rated Current (A) 40°C (104°F) In— — — — — — 63–125 63–125
Rated Voltage Ue230 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V 440 V
Ultimate Breaking Capacity (Icu)
as per IEC 60947-2 Standard
130 Vac
230–240 Vac
400–415 Vac
440 Vac
—
7.5 kA
21 kA
—
—
10 kA
31 kA
—
—
20 kA
10 kA
6 kA
30 kA
15 kA
41 kA
—
—
30 kA
15 kA
10 kA
—
25 kA
61 kA
—
—
50 kA
25 kA
20 kA
30 kA
15 kA
41 kA
—
—
30 kA
15 kA
10 kA
1P 60 Vdc
2P 125 Vdc
—
—
—
15 kA
—
—
—
2P 20 kA
3P 30 kA
20 kA
—
—
—
2P 25 kA
3P 40 kA
25 kA
—
—
—
2P 30 kA
3P 50 kA
—
—
—
—
—
—
3P 250 Vdc — — 4P 40 kA — 4P 50 kA — 4P 60 kA — —
Service Breaking Capacity Ics (%Icu) 50% 75% 75% 50% 50% 50% — 75% 75%
Magnetic Trip Curves
B Curve
C Curve
D Curve
K Curve
MA Curve
Z Curve
3–5
7–10
—
—
—
—
—
7–10
10–14
—
—
—
—
7–10
10–14
—
—
—
—
7–10
10–14
10–14
12
2.4–3.6
3.2–4.8
7–10
10–14
—
—
—
1Single pole breaking capacity for IT type European grounding system (insulated neutral-double fault).
Table 14: Dimensions and Weights
Device Size Height Width Depth Weight
in. mm in. mm in. mm oz. g
N40 1P 3.19 81 0.71 18 3.00 76 4.23 120
C60N
1P
2P
3P
4P
3.19
3.19
3.19
3.19
81
81
81
81
0.71
1.42
2.13
2.48
18
36
54
72
3.00
3.00
3.00
3.00
76
76
76
76
3.88
7.75
11.64
15.52
110
220
330
440
C60H
1P
2P
3P
4P
3.19
3.19
3.19
3.19
81
81
81
81
0.71
1.42
2.13
2.48
18
36
54
72
3.00
3.00
3.00
3.00
76
76
76
76
4.23
8.47
12.70
16.93
120
240
360
480
C60L
1P
2P
3P
4P
3.19
3.19
3.19
3.19
81
81
81
81
0.71
1.42
2.13
2.48
18
36
54
72
3.00
3.00
3.00
3.00
76
76
76
76
4.23
8.47
12.70
16.93
120
240
360
480
C120H
1P
2P
3P
4P
3.19
3.19
3.19
3.19
81
81
81
81
0.71
2.13
3.19
4.25
27
54
81
108
3.00
3.00
3.00
3.00
76
76
76
76
6.35
12.70
19.05
25.40
180
360
540
720
™
Multi 9™ System Catalog
Section 3—IEC 60947-2 Rated Protection Devices
25
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
N40 Phase + Neutral Circuit Breakers
The N40 Phase + Neutral Current Circuit Breaker provides phase and neutral protection against short-
circuits and overloads. It provides protection on the phase pole, but switches both the phase and
neutral. The N40 is available in only one version—1 phase + neutral. The N40 circuit breaker is
available with C trip curve characteristics and with ratings from 1 to 40 A.
Time/Current Curves
C curve—Provides control and protection against circuit overcurrents in tertiary and industrial final
distribution with TT or TNS grounding systems. Magnetic trip units operate between 5 and 10 times
ampere rating.
Accessories
These devices may be used in conjunction with the C60 electrical accessories, including the SD alarm
switch, OF auxiliary switch, MN undervoltage release, and/or the MX + OF shunt trip and auxiliary switch.
Standards
•
IEC 60947-2
•
IEC 60898
Figure 8:
N2
N1
086031 51
Table 15: Specifications for N40 Phase + Neutral Circuit Breakers
Package size: Two 0.35 in. (9 mm) Modules 0.71 in. (18 mm) Width
Connection: 8 AWG (10 mm2) Stranded Cables
6 AWG (16 mm2) Solid cable (Copper Only)
Mounting: 35 mm DIN rail Mounting: 35 mm DIN Rail
Degree of Protection Case IP40 as per IEC 529
Terminals IP20
Temperature
Calibration 86°F (30°C)
Storage 40 to 176°F (-40 to 80°C)
Operating 22 to 158°F (-30 to 70°C)
Tropicalization Treatment 2 Relative Humidity: 95% at 131°F (55°C) as per IEC 68-2-30
Number of Operating Cycles
Mechanical 20,000 (O-C)
Electrical
20,000 at 1–20 A
15,000 at 25 A
10,000 at 32 A
6,000 at 40 A
See selection table for dimensions, weights and interrupting ratings.
™
Multi 9™ System Catalog
Section 3—IEC 60947-2 Rated Protection Devices
26
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Catalog Numbers
Catalog Numbers for N40 Phase + Neutral Circuit Breakers
Type 1P+N 3P + N
Rating (In) C Curve C Curve
1 A M9P22601 —
2 A M9P22602 —
3 A M9P22603 —
4 A M9P22604 —
6 A M9P22606 M9P22706
10 A M9P22610 M9P22710
16 A M9P22616 M9P22716
20 A M9P22620 M9P22720
25 A M9P22625 M9P22725
32 A M9P22632 M9P22732
40 A M9P22640 M9P22740
Width in 9-mm modules 2 6
N
1N
2N
1N
2
53
6
4
™
Multi 9™ System Catalog
Section 3—IEC 60947-2 Rated Protection Devices
27
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
IEC Rated C60 Miniature Circuit Breakers
The C60 family of Multi 9 circuit breakers meeting IEC 60947-2 is available primarily for equipment for
export from the United States to countries requiring IEC Certification rather than UL Listing.
Three types of IEC Rated C60 devices are available: C60N, C60H, and C60L circuit breakers. These
model numbers refer to the maximum current interrupting (Ultimate Breaking Capacity) ratings.
Each of these devices is available with several characteristic trip curve ratings, as listed in the tables
with catalog numbers. They include devices ranging from 1 to 63 A. (For higher current ratings, select
devices from the higher current C120 series.)
Standard Features
•
Fast closing: Allows increased withstand to the high inrush currents of some loads
•
Trip-free mechanism: Contacts cannot be held in the I-ON position when the C60 device is tripped
automatically.
•
Positive indication of contact disconnect. Green mechanical indication on front face of device
shows that all poles are open.
•
Suitable for reverse feeding.
•
C curve: Overcurrent protection for all application types:
— C60N/H: The magnetic release operates between 5 and 10 times ampere rating.
— C60L: The magnetic release operates between 7 and 10 times ampere rating.
•
D curve: Overcurrent protection for loads with high inrush currents (motors, transformers):
— C60N/H/L: The magnetic release operates between 10 and 14 times ampere rating.
Table 16: Specifications for IEC Rated C60 Miniature Circuit Breakers
High Voltage Withstand 6 kV
Connections (Box Lug) for
C60N/H/L Except C60L-MA1
1Ring tongue terminal is optional.
1–25 A, 18–4 AWG (1–25 mm2) Cu Only Cables Torque to 22 lb-in (2.5 N•m)
30–63 A, 18–2 AWG (1–35 mm2) Cu Only Cables Torque to 31 lb-in (3.5 N•m)
Connections for C60L-MA:
1.5–10 A Stranded 6 AWG (16 mm2) Torque to 35 lb-in (4 N•m)
1.5–10 A Solid 4 AWG (25 mm2) Torque to 18 lb-in (2 N•m)
12.5–40 A Stranded 4 AWG (25 mm2) Torque to 35 lb-in (4 N•m)
12.5–40 A Solid 2 AWG (35 mm2) Torque to 31 lb-in (3.5 N•m)
Mounting 35 mm DIN rail
Time-Current Curves B, C, D, K, and MA
Degree of Protection Case IP40 as per IEC 529
Terminals IP20
Temperature:
Calibration temperature: 30°C (86°F) C60L calibrated at 40°C (104°F)
Storage temperature -40 to 80°C (-40 to 176°F)
Operating temperature -30 to 70°C (-22 to 158°F)
Tropicalization Treatment 2 Relative Humidity: 95% at 131°F (55°C) per
IEC 68-2-30
Number of Operating Cycles Mechanical (O-C) 20,000
Electrical (O-C) 10,000
See selection table for dimensions, weights and interrupting ratings.
™
Multi 9™ System Catalog
Section 3—IEC 60947-2 Rated Protection Devices
28
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Catalog Numbers
Catalog Numbers
C60N Circuit Breaker
Type 1P 2P 3P 4P
Rating (In) C Curve D Curve C Curve D Curve C Curve D Curve C Curve D Curve
1 A M9F11101 M9F12101 M9F11201 M9F12201 M9F11301 M9F12301 M9F11401 M9F12401
2 A M9F11102 M9F12102 M9F11202 M9F12202 M9F11302 M9F12302 M9F11402 M9F12402
3 A M9F11103 M9F12103 M9F11203 M9F12203 M9F11303 M9F12303 M9F11403 M9F12403
4 A M9F11104 M9F12104 M9F11204 M9F12204 M9F11304 M9F12304 M9F11404 M9F12404
6 A M9F11106 M9F12106 M9F11206 M9F12206 M9F11306 M9F12306 M9F11406 M9F12406
10 A M9F11110 M9F12110 M9F11210 M9F12210 M9F11310 M9F12310 M9F11410 M9F12410
16 A M9F11116 M9F12116 M9F11216 M9F12216 M9F11316 M9F12316 M9F11416 M9F12416
20 A M9F11120 M9F12120 M9F11220 M9F12220 M9F11320 M9F12320 M9F11420 M9F12420
25 A M9F11125 M9F12125 M9F11225 M9F12225 M9F11325 M9F12325 M9F11425 M9F12425
32 A M9F11132 M9F12132 M9F11232 M9F12232 M9F11332 M9F12332 M9F11432 M9F12432
40 A M9F11140 M9F12140 M9F11240 M9F12240 M9F11340 M9F12340 M9F11440 M9F12440
50 A M9F11150 —M9F11250 —M9F11350 —M9F11450 —
63 A M9F11163 —M9F11263 —M9F11363 —M9F11463 —
Width in 9-mm modules 2 4 6 8
2
1
2
31
42
531
6
4
2
7531
8
6
4
C60H Circuit Breaker
Type 1P 2P 3P 4P
Rating (In) C Curve D Curve C Curve D Curve C Curve D Curve C Curve D Curve
1 A M9F14101 M9F15101 M9F14201 M9F915201 M9F14301 M9F15301 M9F14401 M9F15401
2 A M9F14102 M9F15102 M9F14202 M9F15202 M9F14302 M9F15302 M9F14402 M9F15402
3 A M9F14103 M9F15103 M9F14203 M9F15203 M9F14303 M9F15303 M9F14403 M9F15403
4 A M9F14104 M9F15104 M9F14204 M9F15204 M9F14304 M9F15304 M9F14404 M9F15404
6 A M9F14106 M9F15106 M9F14206 M9F15206 M9F14306 M9F15306 M9F14406 M9F15406
10 A M9F14110 M9F15110 M9F14210 M9F15210 M9F14310 M9F15310 M9F14410 M9F15410
16 A M9F14116 M9F15116 M9F14216 M9F15216 M9F14316 M9F15316 M9F14416 M9F15416
20 A M9F14120 M9F15120 M9F14220 M9F15220 M9F14320 M9F15320 M9F14420 M9F15420
25 A M9F14125 M9F15125 M9F14225 M9F15225 M9F14325 M9F15325 M9F14425 M9F15425
32 A M9F14132 M9F15132 M9F14232 M9F15232 M9F14332 M9F15332 M9F14432 M9F15432
40 A M9F14140 M9F15140 M9F14240 M9F15240 M9F14340 M9F15340 M9F14440 M9F15440
Width in 9-mm modules 2 4 6 8
2
1
2
31
4
2
531
6
4
2
7531
8
6
4
™
Multi 9™ System Catalog
Section 3—IEC 60947-2 Rated Protection Devices
29
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Catalog Numbers
C60L Circuit Breaker
Type 1P 2P 3P 4P
Rating (In) C Curve
1 A M9F17101 M9F17201 M9F17301 M9F17401
2 A M9F17102 M9F17202 M9F17302 M9F17402
3 A M9F17103 M9F17203 M9F17303 M9F17403
4 A M9F17104 M9F17204 M9F17304 M9F17404
6 A M9F17106 M9F17206 M9F17306 M9F17406
10 A M9F17110 M9F17210 M9F17310 M9F17410
16 A M9F17116 M9F17216 M9F17316 M9F17416
20 A M9F17120 M9F17220 M9F17320 M9F17420
25 A M9F17125 M9F17225 M9F17325 M9F17425
Width in 9-mm modules 2 4 4 6
2
1
2
31
4
2
531
6
4
2
7531
8
6
4
™
Multi 9™ System Catalog
Section 3—IEC 60947-2 Rated Protection Devices
30
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
IEC Rated C120H Circuit Breakers
The IEC Rated C120H family of Multi 9 circuit breakers meets the requirements of IEC 947-2 and are
available for OEMs wishing to export manufactured products to countries requiring IEC Certification
instead of UL Listing.
They are suitable for protection of cables against overloads and short circuits in equipment. They can
also be used for manual control and isolation of circuits.
The C120H circuit breakers are available in B, C, and D trip curves, as listed in Table 19. They include
devices ranging from 63 to 125 A. (For lower current ratings, select devices from the C60 series.)
Standard Features
•
Fast closing: Allows increased withstand to the high inrush currents of some loads.
•
Trip-free mechanism: Contacts cannot be held in I-ON position when C120 is tripped automatically.
•
Isolation with positive break indication: Green strip on operating handle indicates all poles are open
•
Terminals ensure pull-out withstand of cables, guiding of cables into correct position, and
tightening of wide cross-section cables.
•
B curve: Overcurrent protection of very long cables and protection of networks supplied by
generators. The magnetic release operates between 3 and 5 times ampere rating.
•
C curve: Overcurrent protection for all application types. The magnetic release operates between 5
and 10 times ampere rating.
•
D curve: Overcurrent protection for loads with high inrush currents (motors, transformers). The
magnetic release operates between 10 and 14 times ampere rating.
•
Suitable for reverse feeding.
Table 17: IEC 947-2 Rated C120H Circuit Breakers
2P 3P 4P
1P
Table 18: Specifications for IEC Rated C120H Circuit Breakers
Package Size Three 9 mm Modules 27 mm Width per Pole
Voltage High Voltage Withstand 6 kV
Maximum Voltage Rating 440 Vac
Connection: Box Lug, 10–100 A 18 to 1 AWG (1–50 mm2) Cables Cu Wire Only
Mounting 35 mm DIN Rail
Degree of Protection: Case IP40 as per IEC 60529
Terminals IP20
Time/Current Curves B, C and D Curves
Temperature:
Calibration 30°C (85°F)
Storage -40 to 80°C (-40 to 176°F)
Operating -30 to 70°C (-22 to 158°F)
Tropicalization Treatment 2 Relative Humidity: 95% at 55°C (131°F) as per IEC 68-2-30
Number of Operating Cycles 1000 (O-C) at 63 A
5000 (O-C) at 80–125 A
™
Multi 9™ System Catalog
Section 3—IEC 60947-2 Rated Protection Devices
31
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Accessories
Ground-fault protection can be provided when combined with a Vigi C120 module. Remote tripping
and indication can be provided by adding a variety of auxiliaries (see section 5 for accessories).
NOTE: The C120 circuit breakers use the same electrical auxiliaries as the C60 circuit breakers. They
do not accept the NC100H circuit breaker accessories.
Standards
•
IEC 60947-2
•
VDE 0660
•
CE Marked
Catalog Numbers
Table 19: Catalog Numbers for Multi 9 C120H (10–125 A) Circuit Breakers—15 kA at 240 Vac
Rating 1P 2P 3P 4P
B Curve (Magnetic Setting Between 3 and 5 Times Ampere Rating)
63 A A9N18401 A9N18412 A9N18423 A9N18434
80 A A9N18402 A9N18413 A9N18424 A9N18435
100 A A9N18403 A9N18414 A9N18425 A9N18436
125 A A9N18404 A9N18415 A9N18426 A9N18437
C Curve (Magnetic Setting Between 5 and 10 Times Ampere Rating)
63 A A9N18445 A9N18456 A9N18467 A9N18478
80 A A9N18446 A9N18457 A9N18468 A9N18479
100 A A9N18447 A9N18458 A9N18469 A9N18480
125 A A9N18448 A9N18459 A9N18470 A9N18481
D Curve (Magnetic Setting Between 10 and 14 Times Ampere Rating)
63 A A9N18489 A9N18500 A9N18511 A9N18522
80 A A9N18490 A9N18501 A9N18512 A9N18523
100 A A9N18491 A9N18502 A9N18513 A9N18524
125 A A9N18492 A9N18503 A9N18514 A9N18525
™
Multi 9™ System Catalog
Section 4—Ground-Fault Protection Devices
32
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Section 4—Ground-Fault Protection Devices
Selection Table
The Multi 9 System includes one UL Listed and three IEC rated product families that provide ground-fault
protection. These products are summarized below and discussed in more detail in the following pages.
Table 20: Selection Table for Multi 9 Ground-fault Protection Products
GFP ID C60 Vigi
Standard UL 1053
IEC 61008 IEC 61008 IEC 61009
Number of Poles 2P 2P 4P 2P 4P 2P 2P 3P 4P
Rated Current (A)
25°C (77°F) — — — 25–100 25–100 < 63 < 63 < 63 < 63
Sensitivities
Instantaneous
10 mA
30 mA
100 mA
300 mA
500 mA
—
25–63
25–63
25–100
—
—
25–63
25–63
25–100
—
—
25–63
25–63
25–100
—
Yes
Yes
—
Yes
—
—
Yes
—
—
—
—
Yes
—
Yes
—
Yes
Yes
—
—
—
—
Yes
—
—
—
—
Yes
—
—
—
Selective
300 1
500 1
1000 1
1 Selective = has non-adjustable time delay to allow selective coordination.
—
—
—
—
—
—
—
—
—
Yes
—
—
Yes
—
—
—
—
—
Yes
—
Yes
Yes
—
Yes
Yes
—
Yes
Voltage (Nominal)
Vac, 50-60 Hz 120, 240 277, 480Y 240,
480Y/277 240/415 130 240/415
Time/Current Curve Depends on Circuit Breaker Used.
Dimensions (in./mm)
Width
Height
Depth
1.42
(36)
3.19
(81)
3.00
(76)
1.42
(36)
3.19
(81)
3.00
(76)
2.84
(72)
3.19
(81)
3.00
(76)
1.42
(36)
3.19
(81)
3.00
(76)
2.84
(72)
3.19
(81)
3.00
(76)
1.42
(36)
3.19
(81)
3.00
(76)
1.42
(36)
3.19
(81)
3.00
(76)
2.13
(54)
3.19
(81)
3.00
(76)
12.84
(72)
3.19
(81)
3.00
(76)
Weight (oz./g) 7.70/
220
7.70/
220
15.9/
450
7.70/
220
15.9/
450
2.43/
120
5.29/
150
< 25 = 6.35 /180
> 63 = 7.41/210
In
Pickup
s
s
s
s
Table 21: Overcurrent Protection Required for UL Applications of GFP
GFP
C60 Circuit Breaker
25 A, 240 Vac 20 A, 277 Vac 20 A, 480Y/277 Vac
1P and 2P 3 P 1P 2P 3P
2P 240 Vac 10 — — — —
2P 480Y/277 Vac — — 10 10 —
4P 480Y/277 Vac — 10 — — 10
™
Multi 9™ System Catalog
Section 4—Ground-Fault Protection Devices
33
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
UL 1053 Listed GFP Ground Fault Protectors
The GFP Ground Fault Protector provides ground fault protection for electrical circuits. It will
automatically open the circuit in the case of a ground fault between phase and ground greater than 10,
30 or 300 mA, depending on the model. An electromechanical release operates without any auxiliary
source of supply to open the circuit. The GFP is available in 2-pole and 4-pole (3 or 4-wire) versions.
NOTE: The GFP has only one protective function—detection of ground fault current. There is no
thermal or magnetic overcurrent protection. Therefore, the circuit must be protected upstream by an
approved device such as the Multi 9 C60, QOU, QO, or HGL circuit breaker, or a fuse.
Multi 9 GFP products contain Si technology to increase immunity to noise and to minimize the potential
for nuisance tripping in noisy electrical environments.
The toggle on the front of the GFP is used to reset the device after it has tripped. It should not be used
to switch loads. A test button located on the front of the GFP is provided to allow periodic testing of the
device. The tripped condition due to ground fault is displayed on the front face by a red mechanical
indicator.
Remote monitoring and control can be provided with optional C60 accessories including the OF
Auxiliary Switch, SD Alarm Switch, MN Undervoltage Release and/or MX + OF Shunt Trip.
NOTE: These auxiliaries require the use of the OFS Auxiliary Switch (Cat. No. 26923) to adapt to the
ID Residual Current Switch.
Standards
•
UL 1053 (not CSA certified)
•
IEC 61008
•
CE Marked
Table 22: Specifications for UL 1053 Listed GFP Ground Fault Protectors
Voltage Rating
Two Poles at 120 or 240 Vac (-15/+10%)
Two Poles at 277 or 480Y/277 Vac (-15/+10%)
Four Poles at 240 Vac or 480Y/277 Vac (-15/+10%)
Current Rating (40°C) 25 A, 40 A, 63 A, 80 A or 100 A Depending on catalog number
Ground Fault Sensitivity:
GFP30 Must trip at 29.9 mA; must not trip below 22.1 mA
GFP100 Must trip at 98.9 mA; must not trip below 73.1 mA
GFP300 Must trip at 299 mA; must not trip below 221 mA
Short-Circuit Current Rating 10 kA with recommended circuit breaker or
fuse upstream See bulletin GHA1080850AB
Frequency 50 or 60 Hz
Mounting 35 mm DIN rail
Connection, Box Lug Wire: 75°C copper wire only, stranded or solid
14 to 2 AWG (2.5 to 35 mm2)Torque to 31 lb-in (3.5 N•m)
Padlocking in the “Tripped”
Position is Possible Use a padlocking device Requires addition of OFS on left side of circuit
breaker plus padlocking attachment M9PAFL
Ground-Fault Indication Red indicator flag on front face
Temperature Operating temperature -25 to +60°C (-13 to +140°F)
Storage temperature -40 to +70°C (-40 to + 158°F)
Tropicalization Treatment 2 Relative humidity 95% at 55°C (131°F)
See Table 20 on page 32 for dimensions and weights.
™
Multi 9™ System Catalog
Section 4—Ground-Fault Protection Devices
34
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Catalog Numbers
Table 23: Catalog Numbers for UL Rated GFP Ground Fault Protectors
Poles Voltage Current Maximum
Sensitivity Tripping Range Family Catalog
Number
2P
UL 1053
120/240 V, 240 V
60 Hz
IEC 61008
230 V, 240 V
50 Hz
25 A
30 mA
100 mA
300 mA
22.1 to 29.9 mA
73.1 to 98.9 mA
221 to 299 mA
GFP 30
GFP 100
GFP 300
60949
60950
60951
40 A 30 mA
300 mA
22.1 to 29.9 mA
221 to 299 mA
GFP 30
GFP 300
60952
60954
63 A 30 mA 22.1 to 29.9 mA GFP 30 60955
2P
UL 1053
277 V, 480Y/277 V
60 Hz
IEC 61008
230/400 V, 240/415 V
50 Hz
25 A 30 mA
300 mA
22.1 to 29.9 mA
221 to 299 mA
GFP 30
GFP 300
60969
60971
40 A 30 mA 22.1 to 29.9 mA GFP 30 60972
4P
UL 1053
240 V, 480Y/277 V
60 Hz
IEC 61008
230/400 V, 240/415 V
50 Hz
25 A
30 mA
100 mA
300 mA
22.1 to 29.9 mA
73.1 to 98.9 mA
221 to 299 mA
GFP 30
GFP 100
GFP 300
60989
60990
60991
40 A 30 mA
300 mA
22.1 to 29.9 mA
221 to 299 mA
GFP 30
GFP 300
60992
60994
63 A 30 mA
100 mA
22.1 to 29.9 mA
73.1 to 98.9 mA
GFP 30
GFP 100
60995
60996
100 A 300 mA 221 to 299 mA GFP 300 60999
Figure 9: Possible Device Combinations
+++
GFP
Ground Fault Protector
OFS Auxiliary Switch
Required in order
to mount either/both
indicated accessories.
MX Shunt Trip
and/or
MN Undervoltage
Release
OF Auxiliary Switch
and/or
SD Alarm Switch
™
Multi 9™ System Catalog
Section 4—Ground-Fault Protection Devices
35
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
IEC Rated ID Residual Current Switches
The ID Residual Current Switches provide ground fault protection for electrical circuits, as well as the
functions of isolation and switching. ID switches have an electromechanical release that opens a circuit
automatically in the case of a fault between phase and earth greater than 10, 30, or 300 mA,
depending on the model. The switch operates without the need for an auxiliary source of power. A
version with time delay (selective) provides non-adjustable time delay for coordination with
downstream instantaneous residual current devices. The ID Switch is available in 2-pole (1-phase) and
4-pole (3-phase) versions.
The ground fault is displayed on the front face by a red mechanical indicator.
NOTE: The ID residual current switch has only one protective function—detection of earth leakage
current. There is no thermal or magnetic overcurrent protection. Therefore, the circuit must be
protected by an upstream circuit breaker or supplementary protector. For combined overcurrent and
residual current protection, an alternative is a C60 circuit breaker equipped with an auxiliary Vigi
ground-fault detector module.
The ID device can also be manually operated as a switch. Remote monitoring and control can be
provided with optional C60 accessories including the OF Auxiliary Switch, SD Alarm Switch, MN
Undervoltage Release, and/or MX + OF Shunt Trip.
NOTE: All of these auxiliaries require the use of the OFS Auxiliary Switch (Cat. No. 26923) to adapt to
the ID Residual Current Switch.
A test button provided on the front of the ID Residual Current Switch to allow periodic testing of the
device.
Figure 10: IEC Rated ID Residual Current Switches
Table 24: Specifications for IEC Rated ID Residual Current Switches
Voltage Nominal voltage 240 to 415 Vac, +10%, -20%, 50/60 Hz
High voltage withstand 6 kV
Connection, Box Lug
14–2 AWG (2.5–35 mm2) stranded cables,
Cu wire only Torque to 31 lb-in (3.5 N•m)
1 AWG (50 mm2) solid cables, Cu wire only Torque to 31 lb-in (3.5 N•m)
Sensitivities Fixed at 10, 30, or 300 mA
Time/Current Curve Instantaneous or selective release S (Time Delay)
Level of Immunity 250 A Peak According to 8/20 ms periodical wave
Operating Temperature -5 to 60°C (22 to 140°F)
Tropicalisation Treatment 2 Relative humidity: 95% at 55°C (131°F) per IEC 68-2-30
Mounting 35 mm DIN Rail
Number of Operating Cycles Electrical (O-C) 20,000
See Table 20 for weights, dimensions and interrupting ratings.
™
Multi 9™ System Catalog
Section 4—Ground-Fault Protection Devices
36
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Standards
•
IEC 61008
•
CE Marked
Catalog Numbers
Table 25: Catalog Numbers for IEC ID Residual Current Switches—AC Class
Rating Sensitivity
(mA)
2P (240 Vac)
4 Modules
4P (415 Vac)
8 Modules
25 A 30 M9R11225 —
40 A 30
300
M9R11240
M9R14240
M9R11440
M9R14440
Figure 11: Possible Device Combinations
+++
OFS Auxiliary Switch
Required in order
to mount either/both
indicated accessories.
MX Shunt Trip
and/or
MN Undervoltage
Release
OF Auxiliary Switch
and/or
SD Alarm Switch
ID Residual Current
Switch
™
Multi 9™ System Catalog
Section 4—Ground-Fault Protection Devices
37
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
IEC Rated C60 Vigi
TM
Modules for Ground-fault Protection
The C60 Vigi residual current detector can be added to the C60 circuit breaker to provide a high level
of protection against earth leakage faults. The Vigi module clips onto the right-hand side of a C60
protective device and is mechanically linked to the C60 circuit breaker, which it trips when the Vigi
detects residual current. Vigi modules are available for use with 2-, 3-, and 4-pole C60 circuit breakers.
The Vigi module may be field installed.
The Vigi module combines a current sensing toroid and residual current relay in one case and
operates without an auxiliary power supply source. It may be ordered with a variety of non-adjustable
sensitivities (10 to 1,000 mA). A version with time delay (selective) provides non-adjustable time delay
for coordination with downstream instantaneous residual current devices.
A built-in filtering device minimizes nuisance tripping due to transient voltages (lightning, line
disturbances, etc.) and transient currents (from high capacitive circuits).
A visual indicator of the ground fault is provided by a red flag on the Vigi operating handle. A manual
test button on the face of the Vigi module allows manual testing of the Vigi module.
The C60 Vigi module can be field-adapted to reset in one of two modes: Automatic reset when the
associated protective device handle is reset, or by manually resetting the Vigi prior to reclosing the
supplementary protector.
A version with time delay (selective) provides additional time discrimination with downstream
instantaneous residual current devices.
NOTE: The C60 version of the Vigi Module cannot be used with the C120 series. A different series of
Vigi Modules is available for the C120 devices.
NOTE: Also see the ID Residual Current Switches.
Figure 12:
Vigi Module
Figure 13: Example of Residual Current Circuit Breaker
Table 26: Specifications for IEC Rated C60 Vigi Modules for Ground-Fault Protection
Voltage (Nominal): 130–240 Vac +10/ -20%, 50/60 Hz
220–415 Vac +10/ -20%, 50/60 Hz
High Voltage Withstand: 6 kV 6 kV
Connection: Box Lug:
≤ 25 Stranded 6 AWG (16 mm2) Cu Wire 4 N•m
≤ 25 Solid 6 AWG (16 mm2) Cu Wire 2 N•m
≤ 63 Stranded 6 AWG (16 mm2) Cu Wire 4 N•m
≤ 63 Solid 6 AWG (16 mm2) Cu Wire 3.5 N•m
Mounting 35 mm DIN rail
Time-Current Curves Depends on Circuit Breaker
Time/Current Curve Instantaneous or Selective Release
Sensitivities Fixed at 10, 30, 300, or 1000 mA
Temperatures Calibration 77°F (25°C)
Operating 22 to 140°F (-5 to 60°C)
See Table 20 on page 32 for weights, dimensions and interrupting ratings.
+=
Vigi ModuleC60 Circuit Breaker Residual Current Circuit Breaker
s
™
Multi 9™ System Catalog
Section 4—Ground-Fault Protection Devices
38
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Accessories
Terminal screw shields prevent contact with the Vigi module terminal screws. The bag includes twenty
pieces of single-pole shields (Cat. No. 26982).
Standards
Combined with C60, the Vigi module forms a residual current device which conforms to the following
standards:
•
IEC 61009
•
EN 61009
Catalog Numbers
Table 27: Catalog Numbers for Vigi C60 Modules—AC Class (Not UL/CSA Recognized)
Rating Voltage
Sensitivity
(mA) 2P 2P 3P 4P
≤ 63 A 220–415 Vac 30
300 1
1
Selective = has non-adjustable time delay to allow selective coordination.
—
—
M9V11263
M9V14263
M9V11363
M9V14363
M9V11463
M9V14463
Figure 14: IEC Rated C60 Vigi Modules
s
s
™
Multi 9™ System Catalog
Section 4—Ground-Fault Protection Devices
39
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
IEC Rated C120 Vigi Residual Current Circuit Breakers
The C120 Vigi residual current detector can be added to the C120 circuit breaker to provide a high
level of protection against earth leakage faults. The Vigi module clips onto the right-hand side of a
C120 protective device and is mechanically linked to the C120 circuit breaker, which it trips when the
Vigi detects residual current.
The C120 circuit breaker and Vigi module combination is reset in a single operation by resetting the
circuit breaker.
The Vigi module combines a current sensing toroid and residual current relay in one case and
operates without an auxiliary power supply source. It may be ordered with a variety of non-adjustable
sensitivities (30 to 1,000 mA). A version with time delay (selective) provides additional time
discrimination with downstream instantaneous residual current devices.
Vigi modules combine with the C120 2-, 3- and 4-pole circuit breakers to provide:
•
Protection of people against indirect contact (per IEC Standards)
•
Additional protection of people against direct contact (30 mA)
•
Protection of electrical installations against insulation faults
The C120 circuit breaker and Vigi module combination is protected against nuisance tripping due to
transient overvoltages such as lightning, switching on the network, etc.
Standards
Complies with IEC 1009 Standard
Catalog Numbers
Figure 15:
2P C120 Vigi
Module
Table 28: Specifications for IEC Rated C120 Vigi Residual Current Circuit Breakers
Current Rating 125 A
Guarantees Tripping for Sinusoidal
AC Residual Currents Either suddenly applied or slowly increasing
Total Vertical Discrimination with
the IΔn 300 mA to 1 A
“Selective” Sensitivities if it is
Installed:
Upstream from an instantaneous residual
current device
Downstream from an Index II, Time-Delayed
Residual Current Device
Where in both cases the IΔn of the downstream
device ≤ IΔn/2 of the upstream device
Connections 16–2 AWG (1–35 mm2) stranded wire 31 lb-in (3.5 N•m)
16–1 AWG (1–50 mm2) solid wire 31 lb-in (3.5 N•m)
Voltage 220–415 Vac +10%, -20%, 50/60 Hz
Mechanical Indication Red indicator On front face of the Vigi module
Instantaneous or Selective Tripping Fixed sensitivities for all ratings
See Table 20 on page 32 for weights and interrupting ratings.
Table 29: Catalog Numbers for IEC C120 Vigi Si (Noise Immune) Module—AC Class
Rating Voltage Sensitivity (mA) 2P 3P 4P
125 A 220–415 Vac
30 A9N18591 A9N18594 A9N18597
300 A9N18592 A9N18595 A9N18598
300 1
1
Selective = has non-adjustable time delay to allow selective coordination.
A9N18556 A9N18558 A9N18560
500 ——A9N18599
1000 A9N18557 A9N18559 A9N18561
s
s
s
™
Multi 9™ System Catalog
Section 4—Ground-Fault Protection Devices
40
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
N40 Vigi Residual Current Circuit Breaker
Function
•
The DPN N Vigi residual current device provides complete protection of final circuits (overcurrents
and insulation faults):
— protection of people against electric shocks by direct contacts (30 mA),
— protection of people against electric shocks by indirect contacts (300 mA),
— protection of installations from fire hazards (300 mA).
•
Fast closing.
•
Positive break indication.
•
Display of earth fault on the front panel by position of toggle.
•
The "si" range has been designed to maintain a network with optimum safety and continuity of
service in installations disturbed by:
— extreme atmospheric conditions,
— harmonic generating loads,
— transient operating currents.
Catalog Numbers
Standards
•
European standard EN 61009.
•
International standard IEC 61009.
Figure 16: IEC Rated C120 Vigi
TM
Modules
Table 30: N40 VIGI Residual Current Circuit Breaker
Rating (A) 1-pole + N (C Curve) 4 Modules Width in
9-mm
Modules
30 mA 300 mA
10
16
20
25
40
M9D11610
M9D11616
M9D11620
M9D11625
M9D11640
M9D14610
M9D14616
M9D14620
M9D14625
M9D14640
4
Voltage Rating (Ue) 230 Vac
Operating Frequency 50/60 Hz
08603161
1 3
42
➞
T
2-pole C120 Vigi Module
08603180
1 3 5
246
➞
T
3-pole C120 Vigi Module
08603181
8
246
1 3 5 7
➞
T
4-pole C120 Vigi Module
™
Multi 9™ System Catalog
Section 5—Accessories
41
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Section 5—Accessories
The Multi 9 System includes an extensive line of field-installable accessories that enables the system
to be used in many applications. Electrical auxiliaries include shunt trip, undervoltage release, auxiliary
switch, and alarm switch. Control and display devices include push buttons, motor operators, and
signal lamps. Also available is a variety of accessories for locking, operating, shielding, mounting, etc.
Other devices include switches and timers. The following diagram shows many of the accessories.
All of the accessories described in this section may be field-installed. These include electrical
auxiliaries, comb bus bars, mounting devices, shielding and identification systems, operators, and
display, status, and control devices.
Figure 17: Overview of Multi 9 System Accessories
T
111111111111111111
DDDDDDDDDDDDDDDDDD
O-OFF
O-OFF
11 12 13
8
7
9
1
O-OFF
14 15
210
3456
16 17 18
1. DC Circuit Breaker (UL 489A)
2. C60 UL 1077 Recogniz ed Supplementary Protectors or
UL 489 Listed Circuit Breakers
3. Undervoltage Release (MN)
4. Shunt Trip (MX + OF)
5. Auxiliary Switch (OF)
6. Alarm Switch (SD)
7. Comb Bus Bar
8. Connector
9. Ring Tongue Terminal Kit
10. C60N/NC100 Vigi Module
11. Terminal Cover
12. Interphase Barrier
13. Terminal Screw Shield
14. Padlock Attachment
(Off Position)
15. Plug-in Base
16 Rotary Handle
17. Spacer
18.
19. Left Side Padlock Attachment
20. Right Side Padlock Attachment
Identification System
or
08603523
or
oror
or
19
20
or or or
15 mm
PZ2
5.5 mm
Rating Tightening Torque Copper Cables
Rigid Flexible or with End-Piece
4–40 A 3.5 N•m 1–16 mm21–10 mm2
™
Multi 9™ System Catalog
Section 5—Accessories
42
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Electrical Auxiliaries
The Multi 9 product line includes a variety of electrical auxiliaries for the C60, N40, and C120
supplementary protectors and circuit breakers. They may be attached to the protective device as
needed to fulfill the tripping or monitoring application requirements. They include the following devices:
•
MN Undervoltage Release
•
MX + OF Shunt Trip and Auxiliary Switch
•
OF Auxiliary Switch
•
SD Alarm Switch
•
OFS Special Auxiliary Switch (For use with GFP and ID RCCB’s, allows other accessories to be
mounted to the side of the GFP.)
The Multi 9 Vigi Module, which adds ground-fault protection, is described in Section 4.
Accessories have a maximum width of 54 mm and are mechanically linked to the base C60, N40 or
C120 protective devices.
Figure 18: Possible Auxiliary Combinations
Table 31: Catalog Numbers for Electrical Auxiliary Devices
Device
Control Voltage Modules
(9mm)
C60 / GFP / N40 C120
Vac Vdc UL/IEC IEC IEC
MX + OF
Shunt Trip + Aux Switch
24
48
110-240-277
220-277
24
48
125
—
2
2
2
—
27118
27110
27109
—
27118
27110
27109
—
A9N20948
A9N26947
A9N26946
—
MN
Undervoltage Release
24
48
120
240
24
48
—
—
2
2
2
2
27108
27106
27107
27105
27108
27106
27107
27105
—
A9N26961
—
A9N26960
OF
Auxiliary Switch 12-277 12-125 1 MG26925 26924 26924
SD
Alarm Switch 12-277 12-125 1 MG26928 26927 26927
OFS
Alarm Switch for GFP Only 240/415 130 1 — — 26923
C60 Supplementary
Protector or
Circuit Breaker
L or +
N or –
91
94 92
Fault
Normal
08603149
L or +
N or –
11
14 12
Closed
Open
08603148
L or +
N or –
Closed
Open
C1
14 12
U>
C2
08603150
u >
D1
D2
L or +
N or –
08603146
MN Undervoltage
Release
MX + OF Shunt Trip
and Auxiliary Switch
OF Auxiliary SwitchSD Alarm Switch
™
Multi 9™ System Catalog
Section 5—Accessories
43
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
MN Undervoltage Release
The MN Undervoltage Release provides remote tripping of C60, N40 or C120 devices. It causes the device
to trip whenever the MN detects a drop of its control voltage to the range of 70 to 35% of nominal. The
tripped condition is shown by a red indicator flag on the front panel of the MN undervoltage release. The MN
undervoltage release is mechanically linked to the C60, N40 or C120 device. It may be used in conjunction
with the SD Alarm Switch, OF Auxiliary Switch, and/or the MX + OF Shunt Trip and Auxiliary Switch.
NOTE: The tripped circuit breaker or supplementary protector must be manually reset. The MN
Undervoltage Trip prevents the device from being reclosed until the control voltage has been restored.
Models must be selected depending on the level of control voltage source (ac or dc).
•
Used for emergency stop via push button.
•
Used as safety feature on circuit supplying several machines, to prevent uncontrolled restarting of
motors.
•
UL Recognized for use with UL 1077 Recognized devices and UL Listed for use with UL 489/CSA
C22.2 No.5 Listed devices.
•
CSA and IEC Rated
The linkage is mechanical, thus ensuring the integrity of the protection function. Multiple auxiliaries may
be used in combination with a single C60, N40 or C120 protective device. Terminal pads for connection
of control wiring are provided for either one or two 16–14 AWG (1.5–2.5 mm
2
) cables.
MN Time-delayed Undervoltage Release
The time-delayed undervoltage release is identical to the standard MN undervoltage release, except
that it allows brief interruptions of control power without opening the circuit breaker due to
undervoltage. It allows a 0.5 second time delay before opening the associated protective device.
MX + OF Shunt Trip and Auxiliary Switch
The MX + OF switch combines the functions of shunt trip and auxiliary switch into one device. The MX
Shunt Trip, when energized by a control voltage, provides remote tripping of the associated C60 or
N40 circuit breakers or supplementary protectors to which it is mechanically linked.
The tripped condition is indicated by a red indicator flag on the front panel of the MX + OF. The
protective device must be manually reset after being tripped by the MX.
NOTE: When the OF function is combined with the MX Shunt Trip, no test button is provided.
The MX + OF Switch may be used in conjunction with the SD Alarm Switch, which presents the trip
status, and/or the MN Undervoltage Release.
•
UL Recognized for use with UL 1077 Recognized devices and UL Listed for use with UL 489/CSA
C22.2 No.5 Listed devices.
•
CSA and IEC Rated.
Table 32: Power Consumption of MX and MN Accessories
Type Voltage VA or W Type Voltage VA or W
MX (inrush)
415 Vac
220–240 Vac
48–130 Vac
110–130 Vdc
48 Vac/Vdc
24 Vac/Vdc
120
50
200
10
22
120
MN (holding)
220–240 Vac
48 Vac
48 Vdc
4.1
4.3
2.0
MN (holding)1
1IEC Rated; not UL/CSA Recognized.
220–240 Vac 4.1
Table 33: Wiring for MX and MN Accessories
Wire Torque
16–14 AWG (0.5–2.5 mm2) solid or stranded wire 9 lb-in. (1 N•m)
s
s
™
Multi 9™ System Catalog
Section 5—Accessories
44
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
OF Auxiliary Switch
The OF Auxiliary Switch communicates the OPEN or CLOSED status of the associated C60 or N40
circuit breaker or supplementary protector via auxiliary contacts. It is mechanically linked to the
supplementary protector (See the SD Alarm Switch for TRIP status).
It may be used in conjunction with the SD Alarm Switch, which presents the trip status, and the MN
Undervoltage Release. It would not normally be used with the MX + OF Shunt Trip because that device
already includes the OF function.
•
UL Recognized for use with UL 1077 Recognized devices and UL 489/CSA C22.2 No.5 Listed devices.
•
CSA and IEC Rated.
OFS Auxiliary Switch and Adapter (for GFP and ID RCD)
The OFS Auxiliary Switch and Adapter has an auxiliary switch to provide the auxiliary switch function
and an adapter which allows the UL Listed GFP ground fault protector and the IEC Rated ID Residual
Current Switches (in Section 4) to use the same electrical accessories as the C60 and N40
supplementary protectors, including the OF Auxiliary Switch, SD Alarm Switch, MN Undervoltage
Release, and/or MX + OF Shunt Trip. It may be used alone or with accessories.
IEC Rated; not UL/CSA Recognized.
SD Alarm Switch
The SD Alarm Switch communicates the trip status of the associated C60, N40 or C120 circuit
breakers or supplementary protectors via auxiliary contacts. It is mechanically linked to the protective
device. Locally, it also indicates a tripped-on-fault condition of the protective device with a red indicator
flag on the front panel. (Use the OF Auxiliary Switch for open or closed status.)
A test switch allows simulation of the SD function without operating the protective device.
The SD Alarm Switch is reset when the associated protective device is reset, or it may by reset
independently of the protective device with a reset lever on its front panel.
The SD Alarm Switch may show the circuit breaker status, using V Type Signal Lamps, other
annunciators, or a control system. It may be used in conjunction with the OF Auxiliary Switch which
presents the open or closed status, the MN Undervoltage Release, and/or the MX + OF Shunt Trip.
•
UL Recognized for use with UL 1077 Recognized devices and UL Listed for use with UL 489/CSA
C22.2 No.5 Listed devices.
•
CSA and IEC Rated
Table 34: Catalog Number for OFS Auxiliary Switch and Adapter
Description Width in Modules Catalog Number
OFS Auxiliary Switch and Adapter 1 26923
Voltage
Breaking
Capacity
(A)
SD OF
277 Vac
< 240 Vac
130 Vac
< 48 Vdc
< 24 Vdc
3
6
1
2
6
3
6
1
2
6
Figure 19: Electrical Auxiliary Schematics
U >
MX + OF Shunt Trip OF Auxiliary Switch
U <
MN Undervoltage Release
14 12 C2 C1 D1 D2 14 12 11
SD Alarm Switch
94 92 91
0860new15
™
Multi 9™ System Catalog
Section 5—Accessories
45
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Comb Bus Bars
UL Recognized C60 and N40 Comb Bus Bars
A Comb Bus Bar can be used to provide common service to a number of Multi 9 supplementary
protectors and accessories. This eliminates the hassle of providing discrete wiring to a number of
protective devices operating from one power source. It is available in 0.71 in. (18 mm) pole spacings
for the C60 and N40 series. It meets the UL 1077 requirements.
These are available in 1-, 2-, or 3-phase (conductor) models, and can be purchased in 12-pole (12P)
lengths.
Field wiring may be applied directly to the comb bus bar by inserting both the conductor and the tooth
of the comb into the same box lug connector of the C60N and N40N supplementary protector.
Refer also to the tooth cap accessories for the comb bus bar.
•
Rated insulation voltage: 480Y/277 Vac
•
Rated current: 63 A service single-feed
•
Available in 1-, 2-, or 3-phases (conductors)
•
Spacing of outgoing poles: 0.71 in. (18 mm)
•
Lengths: Fixed length of 12 poles
•
Height: 0.80 inches (20 mm) above circuit breaker
•
Connection: Comb tooth and main feed wire (10 AWG to 3 AWG) connect to box lug of UL 1077
C60N and C40N supplementary protector
•
UL Recognized for use with UL 1077 devices only; not CSA Recognized
Tooth Caps for UL Recognized Comb Bus Bars
Tooth Caps for UL Recognized Comb Bus Bars may be slipped onto the unused teeth of the Comb
Bus Bar. They come in strips of five with 1-pole spacing, but can be snapped apart to be used
individually.
Figure 20: UL Recognized C60 and N40 3-phase Comb Bus Bar
Table 35: Catalog Numbers for UL Recognized C60 and N40 Comb Bus Bars
Description Length Type Cat. No.
12P Comb Bus Bar 8.5 in. (216 mm)
1Ø
2Ø
3Ø
MG10285
MG10286
MG10287
Figure 21:
Table 36: Tooth Caps for UL Recognized Comb Bus Bars
Description Cat. No.
Tooth Caps for 0.71 in. (18 mm) Comb Bus Bar (20 Pieces) 60488
™
Multi 9™ System Catalog
Section 5—Accessories
46
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Connection Comb Bus Bars for C60 UL 1077 Circuit Breakers
The comb busbars are used only for C60 circuit breakers in conformity with standards UL 1077/
CSA C22.2 No. 3345-04 / IEC 60947-2 / GB 14048-2.
They perform distribution and sub-distribution of the electric power supply and allow rapid assembly
and disassembly of equipment.
IEC
Connection Accessories Comb Bus Bars Tooth Cover End-Place Accessory
Function
• The comb bus bars make it easier to install Schneider Electric UL 1077
circuit breakers
• Power supply directly in the cage of the circuit breaker
• The Tooth Caps are insulated protectors
which may be slipped onto the unused teeth
of the comb busbar
• They come in strips with 1-pole spacing, but
can be snapped apart to be used separately
Number of poles 1P 2P 3P All
Voltage rating (Ue) 4870Y/277 Vac —
Catalog number 10285 10286 10287 60488
Number of 18 mm modules 12 (8.5 in. / 216 mm) 12 (8.5 in. / 216 mm) 12 (8.5 in. / 216 mm) —
Set of 1 1 1 29
Technical Specifications
Insulation Voltage (U) 690 V
Impulse withstand voltage (Uimp)
Acceptable current at 40°C 65 A with 1 central power supply point 100 A with 2 power supply points
Power supply via cable directly in the cage of the device:
• cross section max: 3 AWG (25 mm2)
• cross section min: 10 AWG (5.27 mm2)
Resistance to short-circuit currents Compatible with the breaking capacity of C60 YL 1077 Schneider Electric modular circuit breakers
FIre resistance Self-extinguishability 960°C 30 s/30 s
Color RAL 9001 RAL 1021
8.5
(216)
7.8
(198)
0.7
(18)
0.15
(3.8)
0.06
(1.5)
0.5
(13)
1.4
(35)
0.44
(11.2)
0.87
(22)
Dimensions: :in.
(mm)
™
Multi 9™ System Catalog
Section 5—Accessories
47
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Connection Comb Bus Bars for C60 UL489 Circuit Breakers
The comb busbars are used only for C60 circuit breakers in conformity with standards UL 489 /
CSA C22.2 No.5-02 or IEC 60947-2 /fitted with tunnel terminals.
They perform distribution and sub-distribution of the electric power supply and allow rapid assembly
and disassembly of equipment.
IEC
Country approval pictograms
Connection
Accessories Comb Busbar Insulated Connector Tooth Cover
End-Place
1P x 240 V - 12 modules 3p x 480Y - 12 modules 3p 480Y - Can accept
auxiliaries
Function
• The comb busbars make it easier to install Schneider Electric UL 489 circuit breakers
• They must not be cut
• Comb busbar power supply
• Vertical incoming feeder
• Insulation of teeth
remaining free
Use
• Power supply by insulated connector
• For semi-rigid copper cable of
#1–#12 AWG (4–36 mm2)
• Tightening torque: 53 lb-in
(6 N•m) max.
No. of poles 1P 2P 3P All All
Voltage rating (Ue) 240 Vac 480Y/277 Vac 240 Vac 480Y/277 Vac 240 Vac 480Y/277 Vac 240 Vac 480Y/277 Vac —
Catalog Numbers 10170 10171 10180 10181 10172 10182 10173 10183
10193110175 10185 10190
No. of 18 mm modules 6 12 6 12 12 12 — —
Set of 5 5 5 15 9
Technical Specifications
Insulation voltage (Ui) 1000 V
Impulse withstand
voltage (Uimp) 12 kA
Acceptable current at
40°C (Ia)
240 V: 100 A
480Y: 20 A —
Max. current per feeder ——
Resistance to short-
circuit currents Compatible with the breaking capacity of Schnieder Electric modular circuit breakers —
Fire resistance Self-extinguishiability 960°C 30s/30s
Color RAL9001 RAL1021
Standards UL506 UL485E —
1With spare spaces of 18 mm for electrical auxiliary.
™
Multi 9™ System Catalog
Section 5—Accessories
48
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
IEC Rated C60 Comb Bus Bars
These are available in 1-, 2-, 3- or 4-phase (conductor) models, and can be purchased in 12-pole, 24-
pole, or 54-pole (1 meter) lengths.
Refer also to the accessories for the Comb Bus Bar described below.
•
Rated insulation voltage: 500 Vac as per IEC 664.
•
Rated Current: 100 A service single-feed, 120 A double-feed
•
Available in 1-, 2-, 3-, or 4-phase (conductor) models
•
Spacing of outgoing poles: 18 mm (0.71 in.) on center
•
Lengths:12, 24, or 54 poles; may be cut to desired length
•
IEC Rated
480Y/277 V AC comb busbar and connectors
7.9
(199.4)
5.1
(129.1)
0.7
(17.8)
6.6
(167.6)
5.5
(140.6)
8.4
(213.6)
0.2
(5)
240 V AC comb busbar and connectors
8.4
(213.6) 4.0.7
(17.8)
4.2
(107) 5.2
(132.4)
6.5
(165.3)
4.4
(111.8)
0.2
(5)
Dimensions: :in.
(mm)
Figure 22: IEC Rated C60 Comb Bus Bars and End Caps
Table 37: Catalog Numbers for IEC Rated C60 Comb Bus Bars
Description Length Type Cat. No.
12P Comb Bus Bar 8.5 in. (216 mm)
1Ø
2Ø
3Ø
4Ø
A9XPH112
A9XPH212
A9XPH312
A9XPH412
24P Comb Bus Bar
(package of 2) 17 in. (432 mm)
1Ø
2Ø
3Ø
4Ø
A9XPH124
A9XPH224
A9XPH324
A9XPH424
54P Comb Bus Bar 39.4 in. (1 m)
1Ø
2Ø
3Ø
4Ø
A9XPH157
A9XPH257
A9XPH357
A9XPH457
1-Phase Length
2-Phase Length
3-Phase Length
4 -Phase Length
™
Multi 9™ System Catalog
Section 5—Accessories
49
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
End Caps for IEC Rated C60 Comb Bus Bars
The End Caps are IEC Rated insulating devices which snap onto the ends of the Comb Bus Bar to
retain the bus bars within their protective shield and to ensure the spacing of the conductors.
Connector for IEC Rated Comb Bus Bars
The IEC Rated connectors are provided for connecting field wiring to a comb bus bar.
•
These connectors accept up to 2 AWG wiring.
•
Torque to 22 lb-in (2.5 N•m)
Tooth Caps for IEC Rated Comb Bus Bars
Tooth Caps for IEC Rated Comb Bus Bars are insulated protectors which may be slipped onto the
unused teeth of the Comb Bus Bar. Tooth caps come in strips of five with 1-pole spacing, but can be
snapped apart to be used individually.
Device Shielding
DIN Rail Spacer
The Spacer clips onto a DIN rail to occupy the space of one 0.35 in. (9 mm) module. It can be used to
provide space for future protective devices and accessories. It may also be used to provide a
ventilation gap to prevent overheating.
IEC Rated; not UL/CSA Recognized
Figure 23: Table 38: End Caps for IEC Rated C60 Comb Bus Bars
Description Type Cat. No.
End Caps for Comb Bus Bar
(10 pieces)
1Ø A9XPE110
2Ø A9XPE210
3Ø A9XPE310
4Ø A9XPE410
Figure 24:
Table 39: IEC Rated C60 Connectors
Description Wire Size Cat. No.
Connector (4 Pieces) 2 AWG (25 mm2)A9XPCM04
Table 40: Tooth Caps for IEC Rated Comb Bus Bars
Description Cat. No.
Tooth Caps for Comb Bus Bar (20 pieces) A9XPT920
Figure 25:
Table 41: Catalog Numbers for IEC Rated DIN Rail Spacer
Description Width US No. IEC No.
Spacer for IEC Rated C60 and C120 Circuit Breakers 0.354 in. (9 mm) MG27062 27062
™
Multi 9™ System Catalog
Section 5—Accessories
50
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Interphase
Barriers
The Interphase Barriers snap onto the top and bottom of the C60 devices to provide increased
isolation distance between two adjacent connectors.
NOTE: These are not needed with the versions of C60 with UL 489/CSA C22.2 No.5 Rating nor with
the Ring Lug Terminal kit, since those products already include increased isolation barriers.
IEC Rated; not UL/CSA Recognized
Terminal Screw Shields
The Terminal Screw Shield snaps onto the front of the C60N or C120 protective devices to provide
greater insulation of the terminal screws.
IEC Rated; not UL/CSA Recognized
Terminal Covers
The Terminal Covers completely cover the terminals, either standard or screw-type connectors. They
make the use of the interphase barriers unnecessary.
IEC Rated; not UL 1077/CSA C22.2 No. 235 Recognized
Ring Lug Terminal Kit
The Ring Lug Terminal kit provides isolation barriers and ring terminals to convert a standard box lug
UL 1077 Recognized C60 supplementary protector or UL 489A DC rated Communications circuit
breaker to allow front or rear connection with ring type terminals. The kit allows a UL 1077 Recognized
C60 device
or
UL 489A DC rated Communications to retain its rating. It cannot be field-installed on a
UL 489/CSA C22.2 No.5 Listed C60 product. UL 489/CSA C22.2 No.5 circuit breakers may be ordered
with factory installed ring terminals.
These are user-installed. The Interphase Barriers (or Terminal Covers) cannot be used in conjunction
with the ring tongue terminal kits.
•
Torque for ring tongue into box lug: 30 lb-in. (3.4 N•m).
•
Torque for ring terminal: 18 lb-in (2.0 N•m).
Figure 26:
Table 42: Catalog Numbers IEC Rated Interphase Barrier
Description Quantity US No. IEC No.
Interphase Barriers for C60 Circuit Breakers 10 Pieces MG27001 27001
Figure 27:
Table 43: IEC Rated Terminal Screw Shields for C60 Circuit Breakers
1
1Not for the UL 489/CSA C22.2 No.5 Listed C60 circuit breakers.
Description Quantity Cat. No.
Terminal Screw Shield Bag of 2 strips of 4 MG26981
Table 44: Catalog Numbers for Terminal Covers for C60 Circuit Breakers
1
1Not for the UL 489/CSA C22.2 No.5 Listed C60 circuit breaker.
Description Device Size UL Recognized Cat. No. IEC Rated Cat. No.
Terminal Cover C60
1P
2P
3P
4P
MG26975
MG26976
MG26975 + MG26976
MG26978
26975
26976
26975 + 26976
26978
Figure 28:
™
Multi 9™ System Catalog
Section 5—Accessories
51
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Identification System
Snap-on Marking Symbols
The Identification System provides marking symbols which can be used on the C60 and C120 devices.
They provide pre-labeled, snap-on plastic clips with one character each. They mount just below the
toggle on the C60 devices.
The following symbols are available: Blank, 0-9, +, -, and A-Z.
Orders must specify standard package quantity of 25 strips of each character or multiples of 25.
NOTE: These are same as markers for Telemecanique AB1 terminal blocks.
IEC Rated; not UL/CSA Recognized
Table 45: UL Recognized Ring Lug Terminal Kit
Description Quantity Cat. No.
Ring Lug Terminal Kit
Two Ring Tongue Terminals
Two Isolation Shrouds
Two 5 mm Screws
17400
Figure 29:
Table 46: Catalog Numbers for Snap-on Marking Symbols
Marking Quantity Cat. No. Marking Quantity Cat. No.
A
B
C
D
Strip of 10
Strip of 10
Strip of 10
Strip of 10
AB1GA
AB1GB
AB1GC
AB1GD
1
2
3
4
Strip of 10
Strip of 10
Strip of 10
Strip of 10
AB1R1
AB1R2
AB1R3
AB1R4
E
F
G
H
Strip of 10
Strip of 10
Strip of 10
Strip of 10
AB1GE
AB1GF
AB1GG
AB1GH
5
6
7
8
Strip of 10
Strip of 10
Strip of 10
Strip of 10
AB1R5
AB1R6
AB1R7
AB1R8
I
J
K
L
Strip of 10
Strip of 10
Strip of 10
Strip of 10
AB1GI
AB1GJ
AB1GK
AB1GL
9
0
Strip of 10
Strip of 10
AB1R9
AB1R0
M
N
O
P
Strip of 10
Strip of 10
Strip of 10
Strip of 10
AB1GM
AB1GN
AB1GO
AB1GP
0-9 Strip of 10 AB1R11
Q
R
S
T
Strip of 10
Strip of 10
Strip of 10
Strip of 10
AB1GQ
AB1GR
AB1GS
AB1GT
+
-
Strip of 10
Strip of 10
AB1R12
AB1R13
U
V
W
X
Strip of 10
Strip of 10
Strip of 10
Strip of 10
AB1GU
AB1GV
AB1GW
AB1GX Blank Strip of 10 AB1RV
Y
Z
Strip of 10
Strip of 10
AB1GY
AB1GZ
™
Multi 9™ System Catalog
Section 5—Accessories
52
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Operation Devices
Rotary Handles
A C60 or C120 protection device with 2-, 3-, or 4-poles can be equipped with a rotary handle with an
extension to allow operation of the circuit breaker from either the front or the side (lateral) from the
outside of a panel.
The handle requires that an operating subassembly be affixed to the supplementary protector or circuit
breaker. The operating subassembly requires one of two versions of the rotary handle:
— The first is a fixed handle for front or lateral mounting on a fixed panel.
— The second is a draw-out extended handle which may be mounted on a door or hinged panel.
It mates with the operating subassembly as the door is closed.
•
Minimum depth for drawout is 6.8 in. (174 mm) including circuit breaker.
•
Minimum depth for lateral installation is 4.8 in. (122 mm) including circuit breaker.
•
IEC Rated; not UL/CSA Recognized
Padlock Attachments
The Padlock Attachment clips onto the face of the C60N device to prevent the handle from being
operated. It cannot be installed or removed when padlocked. No tools are needed to install it.
The Padlock Attachment allows the IEC C60 circuit breaker to be locked in either the ON or the OFF
position (UL 489/CSA C22.2 No.5 Listed and UL 1077 Recognized devices can lock in the OFF
position only). The padlock attachment accepts a 0.315 in. (8 mm) diameter padlock, which is not
supplied.
The front plate or functional door can be opened with the circuit breaker locked in the OFF position.
NOTE: Locking the C60 or C120 in the ON position will not prevent the device from tripping under
overcurrent or ground fault conditions.
IEC Rated; not UL/CSA Recognized
Table 47: IEC Rated Rotary Handles
Description US
Cat. No.
IEC
Cat. No.
Operating Subassembly for C60 or
C120 Protection Device (Fixed to
Protection Device)
MG27046 27046
Drawout Extended Handle (Mounted on
Door or Hinged Panel) MG27047 27047
Fixed Handle Front or Lateral (Mounted
on Fixed Panel) MG27048 27048
Operating Subassembly with Lateral Rotary Handle
Padlock Attachment
Table 48: Catalog Numbers for IEC Rated Padlock Attachments
Description Quantity US Cat. No. IEC Cat. No.
Padlock Attachment for C60 Protection Device Bag of 2 MG26970 26970
Heavy-Duty Padlock Attachment for C60N Bag of 1 4LD —
Padlock Attachment for C120 Protection Device Bag of 4 MG27145 27145
™
Multi 9™ System Catalog
Section 5—Accessories
53
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Lock-Off Attachments
,
The Lock-Off Attachment is a permanently-installed, side-mounted accessory for the C60 and C120
circuit breakers to allow locking the circuit breaker in the off position. The attachment is available for
right or left side application and is made of optically clear materials so text on the side of the circuit
breaker can still be read after installation. The lock-off attachment accepts a 0.25–0.375 in. (6–9.5
mm) diameter padlock, which is not supplied.
The front plate or functional door can be opened with the circuit breaker locked in the OFF position.
UL Rated; CSA Recognized
Handle Lockoff Attachment
Table 49: Catalog Numbers for Handle Lock-Off Attachments
Description Left Hand Kit Right Hand Kit
Handle Lock-Off Kit for C60 Protection Device MGN26380 MGN26381
Handle Lock-Off Kit for C120 Protection Device MGN26382 MGN26383
™
Multi 9™ System Catalog
Section 5—Accessories
54
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Mounting Accessories
Plug-in Base
The Plug-in Base allows permanent field wiring connections to be made to the base, so that a C60
device can be plugged in or removed without affecting field wiring.
The Plug-in Base kit includes spade connectors which must be installed on the circuit breaker so it will
mate with the Plug-in Base. The Plug-in Base provides no-load isolation of a circuit protected by C60
supplementary protectors.
While the circuit breaker is removed, the base can be locked using a 0.32 in. (8 mm) dia. padlock (not
provided).
•
Height of base: 7.0 in. (178 mm); with terminal cover extended, 9.3 in. (237 mm)
•
Allow minimum center spacing of 7.87 in. (200 mm) between two rows of bases
•
Multiple bases may be used for multi-pole devices
•
IEC Rated; not UL/CSA Recognized
Front Mounting Bracket (Kit)
The Front Mounting Bracket provides a convenient way to mount Multi 9 circuit breakers, supplementary
protectors or accessories. Its height is equal to a 35 mm DIN rail, and allows the C60 and C120 devices
to be clipped onto it in a standard manner. Its width is available for 1-, 2-, 3-, or 4-pole devices.
In 480 Vac UL 1077 applications, Cat. No. 26981 (C60) or 27152 (C120) Terminal Screw Shield should
be used for increased isolation between the terminal screws of the Multi 9 device and the mounting
bracket. These shields are included with the mounting bracket kits.
UL/CSA Recognized and IEC Rated
NOTE: See dimensional drawings in Section 7.
Figure 30:
Table 50: Catalog Numbers for IEC Rated Plug-in Base
Description US Cat. No. IEC Cat. No.
Plug-In Base for C60 Devices MG26996 26996
Figure 31:
08603537
Table 51: Catalog Numbers for Front Mounting Bracket Ordering Information
Description Size Cat. No.
Front Mounting Bracket for C60 Protective Devices
1P
2P
3P
4P
MG26983
MG26984
MG26985
MG26989
Front Mounting Bracket for C120 Protective Devices
1P
2P
3P
4P
MG26986
MG26987
MG26988
MG26990
™
Multi 9™ System Catalog
Section 5—Accessories
55
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
DIN Rail Mounting Clips
Additional DIN Rail Mounting Clips for Multi 9 products are available.
UL/CSA Recognized Mounting Base for Multi 9 C60 Circuit Breakers
The mounting base for UL 489/CSA C22.2 No.5 240 V Multi 9 C60 miniature circuit breakers is
designed for OEM applications requiring a large number of Multi 9 circuit breakers in a single piece of
equipment. Providing a means for mounting and a bus for line power, this mounting base offers a
convenient solution to powering an entire group of circuit breakers. In addition to simplifying wiring for
multiple UL 489 240 V devices, the mounting base minimizes the cost of installation by eliminating
discrete wiring of line conductors.
The mounting bases for UL 489/CSA C22.2 No.5 240 V Multi 9 C60 circuit breakers are offered in a
variety of configurations, which meet most OEM applications. Available in lengths from 12 to 60 poles,
this mounting base handles the large number of Multi 9 circuit breakers found in OEM equipment.
The standard terminals on the US mounted base are 1-inch wide and have 1/4-20 x 1-in. studs, which
can be used with compression (ring) terminals or with a bus bar. Nuts with washers are provided for
each terminal stud. The terminals of the UL mounting base are aligned with the load terminals of the
PowerPact H- and J-frame molded case circuit breakers. This allows them to be connected using
straight, flat jumper bars.
UL/CSA Recognized for use with U489 240 V Multi 9 C60 miniature circuit breakers per UL 67, CSA
C22.2 No. 29 and IEC 60439-1. Also CE marked.
Figure 32:
Table 52: DIN Rail Mounting Clips
Description Cat. No.
DIN Rail Mounting Clip (Bag of 50) MG27124
Table 53: Specifications for Mounting Base for UL 489/CSA C22.2 No.5 Multi 9 C60 Circuit
Breakers
Voltage 240 Vac
125 Vdc
Ampacity 200 A Maximum, see table below
Withstand Rating 10 ka @ 0.05 seconds
Conductors/Bus 1, 2 and 3 Conductors, Suitable for Use with 1P, 2P and 3P Circuit Breakers
Pole Capacity 12, 24, 36, 48, 60
Branch Circuit Breakers UL 489/CSA C22.2 No.5 240 V C60 with 18 mm Spacing
Input Terminal 1 in. Wide Terminal with 1/4-20 x 1 in. Studs with Nuts/Washers for Compression Ring Lugs, Bus Bar or
Optional Lugs
Table 54: Catalog Numbers for Mounting Base for UL 489/CSA C22.2 No.5 Multi 9 C60 Circuit
Breakers
Poles
1 Conductor 2 Conductors 3 Conductors
Maximum
Amperage Cat. No Maximum
Amperage Cat. No Maximum
Amperage Cat. No
12 200 A US11220018 150 A US21215018 100 A US31210018
24 200 A US12420018 200 A US22420018 200 A US32420018
36 200 A US13620018 200 A US23620018 200 A US33620018
48 200 A US14820018 200 A US24820018 200 A US34820018
60 200 A US16020018 200 A US26020018 200 A US36020018
™
Multi 9™ System Catalog
Section 5—Accessories
56
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Mounting Base Accessories
Wire Lug Kit
The optional Wire Lug Kit, Catalog Number USMBLK, can be field installed for use with cable. Each kit
consists of one lug, one nut and washer assembly. One kit must be ordered for each conductor
terminal. The lug mounts on the 1/4-in. terminal stud of the mount base and is secured with a nut with
washer. This lug accepts 6 AWG to 300 kcmil copper or aluminum cable. The barriers between the
phases provide separation between the phases; an optional terminal cover is also available.
Terminal Cover Kit
The optional Terminal Cover Kit, Catalog Number USMBTC, is designed to provide shielding of the
terminals, bus bars, lugs and cabling. Snapping onto the terminal end of the mounting base, the
terminal cover has an opening for a bus bar jumper and knock-outs to accommodate various sizes of
cable.
Optional Lug Kit USMBLK
Bus Bars Attached
(Not Provided)
Optional Terminal
Cover Kit USMBTC
™
Multi 9™ System Catalog
Section 5—Accessories
57
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Multi-Pole Front Mounting Kit
The Multi-Pole Front Mounting Kit consists of a transparent, hinged, weatherproof cover. It allows
installation of up to twenty modules (10 poles of C60) of Multi 9 circuit breakers or supplementary
protectors and accessories. A DIN mounting rail with support is also available.
•
Degree of protection as per IEC 529: IP55
•
Dimensions (w x h x d): 9.25 x 4.96 x 1.3 in. (235 x 126 x 33 mm)
•
Cutout dimensions: 7.32 x 3.78 in. (186 x 96 mm)
•
IEC Rated; not UL/CSA Recognized
Pole Filler
The Multi 9 M9PF4 pole filler is used to fill empty panel spaces. They clip into the space. Each M9PF4
consists of four strips of four by 18 mm pole fillers (16 poles total). They may be snapped apart in 9 mm
increments.
Figure 33:
Table 55: Catalog Numbers for IEC Rated Multi-Pole Front Mounting Kit
Description Cat. No.
Multi-Pole Front Mounting Kit with Transparent Hinged Cover
(Includes a 10-Module Divisible Blanking Plate and Mounting Template) 14210
DIN Rail with Support 14211
One Strip of M9PF4
Table 56: Pole Filler
Description Cat. No.
Pole Filler, four strips of four by 18 mm M9PF4
™
Multi 9™ System Catalog
Section 6—Additional System Devices
58
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Section 6—Additional System Devices
In addition to the C60 and C120 Circuit Breakers and Supplementary Protectors which form the heart
of the Multi 9 product line, there are a variety of other devices which may be used with C60 or C120
devices or as stand-alone devices.
These include the following:
•
CM Selector Switches (Change-Over)
•
I Current Isolating Switches
•
V Signal Lamps and BP Push Buttons
•
CI Impulse Counters and CH Hour Counters
NOTE: See Section 4 for Ground-Fault Protection Devices.
All of these devices adhere to the Multi 9 packaging format, and can be mounted on a DIN rail in the
protection and control cabinet.
NOTE: See Class 1312 Catalog (document no. 1312CT0101) for recommended protection of the SPD.
CM Selector Switches
The CM Selector Switch allows manual selection of circuits. Different models are available to allow
selection of two or three positions (including off) for one or two circuits. They have maximum ratings of
20 A and 250 Vac and accept cable up to 7 AWG (10 mm
2
). Torque cable to 11 in-lb (1.2 N•m).
This device may be installed on the DIN rail adjacent to the C60 device and its accessories or remotely
in a user interface panel.
IEC Rated; not UL/CSA Recognized
Figure 34:
™
Multi 9™ System Catalog
Section 6—Additional System Devices
59
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Table 57: IEC Rated CM Selector Switches
CM Selector
Switch Type
No. of
Circuits
No. of
Positions
Width in
Modules Cat. No.
122A9E18070
132A9E18073
224A9E18071
234A9E18074
224A9E18072
Figure 35: IEC Rated CM Selector Switch Schematics
1
24
1
24
1
24
5
68
5
684
1
2
1
24
3
N
L
1
4
2Red
Load
Green
08603320
Two
Position
N
L
1
4
2
0
Red
Load
Green
08603321
Three
Position
™
Multi 9™ System Catalog
Section 6—Additional System Devices
60
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
I Current Isolating Switch
The I Isolating Switch provides manual on-load opening or closing of a circuit. Note that it does not
provide either thermal or magnetic protection.
It can be used with the OF auxiliary switch and with other non-electrical accessories in the C60 circuit
breaker family. This device may be installed on the DIN rail adjacent to the C60 device and its
accessories or remotely in a user interface panel.
IEC Rated; not UL/CSA Recognized
Table 58: I Current Isolating Switch Termination
Amperage Wire Type Wire Size Torque
20 and 32 A Stranded 16–6 AWG 1.5–10 mm216 lb-in. 1.8 N•m
Solid 16–6 AWG 1.5–10 mm216 lb-in. 1.8 N•m
40–125 A Stranded 10–1 AWG 6–50 mm240 lb-in. 4.5 N•m
Solid 14–4 AWG 2.5–35 mm240 lb-in. 4.5 N•m
Table 59: Catalog Numbers for IEC Rated I Current Isolating Switches
Rating (A)
1P
(250 Vac)
2 Modules
2P
(415 Vac)
2 Modules
3P
(415 Vac)
4 Modules
4P
(415 Vac)
4 Modules
20
32
40
63
A9S60120
A9S60132
A9S60140
A9S60163
A9S60220
A9S60232
—
—
A9S60320
A9S60332
—
—
A9S60420
A9S60432
—
—
100
125
A9S60191
A9S60192
—
—
—
—
—
—
Figure 36: I Switches
1P 2P 4P
™
Multi 9™ System Catalog
Section 6—Additional System Devices
61
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Status, Display and Control Accessories
There are a variety of other accessories which may be used with the C60 or C120 devices to
communicate control and/or status information. These include the following:
•
V Type Signal Lamps
•
BP Push Buttons
•
CH Hour Counter
•
CI Impulse Counter
These accessories may be located adjacent to the C60 or C120 devices or may be located remotely.
V Signal Lamp
The V Type Signal Lamp indicates when voltage is applied to a circuit and may be used with Multi 9
circuit protection systems or other applications. The lamps are high-efficiency, long-life LEDs. The
lenses are available in a variety of colors.
This accessory device may be installed on the DIN rail adjacent to the C60 devices and its accessories
or remotely in a user interface panel. It accepts cable up to 7 AWG (10 mm
2
). Torque cable to 11 lb-in.
(1.2 N•m).
NOTE: IEC Rated; not UL/CSA Recognized
Table 60: Multi 9 IEC Rated V Indicator Lights
Type Width in 9 mm
Modules Color Cat No.
110-230 Vac
Cat No.
12–48 Vac/Vdc
Single LED Indicator Light
2
Red A9E18320 —
Green A9E18321 —
White A9E18322 —
Blue A9E18323 —
Yellow A9E18324 —
Double LED Indicator Light
2 Green/Red A9E18325 A9E18335
Blinker
2RedA9E18326
™
Multi 9™ System Catalog
Section 6—Additional System Devices
62
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
BP Push Buttons
The BP Push Button device may be used to control Multi 9 circuit protection systems or other
equipment. It provides momentary switching and is available with one N.O., one N.C., or combined
with one each N.O. + N.C. contact.
It is available with or without a signal lamp, which is available in a variety of colors. The lamps are high-
efficiency long-life LEDs.
This device may be installed on the DIN rail adjacent to the C60 and its accessories or remotely in a
user interface panel. It accepts cable up to 7 AWG (10 mm
2
). Torque cable to 11 lb-in. (1.2 N•m).
IEC Rated; not UL/CSA Recognized.
Figure 37:
Push Buttons with
Signal Lamps
Table 61: IEC Rated Multi 9 BP Pushbuttons Catalog Numbers
Type Width in 9 mm
Modules Power Lamp
Color
Pushbutton
Color Circuit Catalog
Number
Single BP
2
Grey 1 NC A9E18030
Red 1 NC A9E18031
Grey 1 NO A9E18032
Grey 1 NO + 1 NC A9E18033
Double BP
2Green/Red 1 NO / 1 NC A9E18034
Grey/Grey 1 NO / 1 NO A9E18035
Single BP + LED Indicator Light
2
110-230 Vac Green Grey 1 NO A9E18036
Red Grey 1 NC A9E18037
12-48 Vac/Vdc Green Grey 1 NO A9E18038
Red Grey 1 NC A9E18039
Figure 38: Schematics for IEC Rated BP Push Button Types
2
1
4
3
2
1
4
3
4x2
3x1
4x2
3x1
Push Buttons without Signal Lamps Push Buttons with Signal Lamps
1 O + C 1 C 1 O 1 C 1 O
08603519
™
Multi 9™ System Catalog
Section 6—Additional System Devices
63
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
CH Hour Counter
The CH Hour Counter is used for measuring the total operating time of a circuit or load. It is capable of
counting to a maximum of 99,999.99 hours. It operates on 224–440 Vac, 50 Hz. The CH must be
installed downstream of a circuit breaker or supplementary protector.
The CH Hour Counter is useful for metering of activity or for scheduling maintenance.
This device may be installed on the DIN rail adjacent to the C60 and its accessories or remotely in a
user interface panel.
NOTE: IEC Rated; not UL/CSA Recognized
CI Impulse Counter
The CI Impulse Counter is an electromechanical counter designed to measure impulses produced by
various devices. It displays the running total of metered impulses up to a maximum count of 9,999,999
impulses. The CI Impulse Counter is unaffected by interruptions in the main power supply.
It is most suitable for counting impulses emitted by detectors such as kilowatt-hour metering,
temperature overrun, etc.
This device may be installed on the DIN rail adjacent to the C60 device and its accessories or remotely
in a user interface panel.
NOTE: IEC Rated; Not UL/CSA Recognized
Figure 39:
Table 62: Information for IEC Rated CH Hour Counter
Wire Size Torque
16–14 AWG 1–2.5 mm20.8 lb-in 1.1 N•m
12
Load
1
2CH
Figure 40: Schematics for IEC Rated CI Impulse Counter
Table 63: CH Hour Counter and CI Impulse Counter
Type Voltage
(Vac)
Frequency
(15% to +6%)
Width in
Modules Cat. No.
CH 220–240 50 Hz 4 15440
CI 220–240 50/60 Hz 4 15443
Table 64: Wiring Information
Wire Size Torque
16–14 AWG 1–2.5 mm20.8 lb-in 1.1 N•m
NL1
CI
LoadLoad
NL1
CI
Kilowatt Meter
(Wh)
08603311
™
Multi 9™ System Catalog
Section 6—Additional System Devices
64
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Kaedra™ Weatherproof DIN Type Enclosures
Applications
•
Expandable enclosures for service, industrial, or equipment applications
•
Protects against water, dust, and chemical and atmospheric agents
•
Kaedra mini-enclosures are designed for small installations (3 to12 modules) replacing
Mini-Pragma™ weatherproof enclosures.
•
Kaedra enclosures come in seven sizes from 12 to 72 modules (18 mm per module).
Standard Features
•
IP 65: as per IEC 60529 for protection against ingress of solids and liquids.
•
IK09: Protection against shocks and resistance to chemical and atmospheric agents, ultraviolet
light, etc.
•
Class 2: Total insulation
•
Flame and abnormal heat resistance: 750°C as per IEC 60695-2-1
•
Conformity with IEC 670 standard for empty enclosures and with IEC 439-3 standard for equipped
switchboards.
•
It is made of insulating material, Class 2, and can be sealed and/or locked (keylock or insert). It
complies with IEC 60439-3 Standards.
Not UL/CSA recognized.
Construction
•
Modern, non-metallic (styrene), sturdy appearance in light gray RAL 7035; smooth surfaces and
rounded corners to increase impact strength.
•
Transparent (green) door for immediate visibility; door can be mounted left or right with clip-on
hinges; secure closing due to multiple latching points; door may be locked to limit access.
•
Punchout holes on four sides and back enable cable insertion throughout.
Installation
•
Can be installed horizontally and/or vertically
•
Enclosures can be combined and added at any time using the association kits to provide
mechanical connection and cable routing.
•
Cabling is quick and efficient with the provided terminal blocks and wiring straps.
•
Distance between rails (125, 150, 175 mm) and rail depth are adjustable. Chassis can be removed
for assembly of equipment.
•
Function identification with a clip-on label with protection cover.
™
Multi 9™ System Catalog
Section 6—Additional System Devices
65
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
NOTE: The Kaedra Weatherproof enclosures replace the Mini-Pragma enclosures.
Accessories
Necessary accessories are included with enclosure, including: Terminal blocks and terminal block
support; one marking kit; Class II plugs.
Other options available are listed in Table 67.
Figure 41:
KAEDRA™ Weatherproof
Mini-Enclosure
08603404
Table 65: Kaedra Weatherproof Mini-Enclosures
1
1Accessories include: terminal blocks and terminal block support; Class II plugs.
Description
Dimensions
Cat. No.WH D
in. mm in. mm in. mm
1 Row of 3 Modules2
2Enclosure modules are 18 mm wide.
3.15 80 5.9 150 3.86 98 13956
1 Row of 4 Modules 4.84 123 7.87 200 4.41 112 13957
1 Row of 6 Modules 6.26 159 7.87 200 4.41 112 13958
1 Row of 8 Modules 7.68 159 7.87 200 4.41 112 13959
1 Row of 12 Modules 10.51 267 7.87 200 4.41 112 13960
Figure 42:
KAEDRA™ Weatherproof
Enclosure
08603405
Table 66: Kaedra Weatherproof Enclosures
1
1Accessories include: Terminal blocks and terminal block support; 1 marking kit per row; 1 wiring strap per row;
Class II plugs, and blanking plates (5 x 18 mm modules per row).
Description
Dimensions
Cat. No.WH D
in. mm in. mm in. mm
1 Row of 12 Modules2
2Enclosure modules are 18 mm wide.
13.39 340 11.02 280 6.23 160 13962
2 Rows of 12 Modules 13.39 340 18.11 460 6.23 160 13964
3 Rows of 12 Modules 13.39 340 24.02 610 6.23 160 13966
1 Row of 18 Modules 13.39 340 11.02 280 6.23 160 13963
2 Rows of 18 Modules 13.39 340 18.11 460 6.23 160 13965
3 Rows of 18 Modules 13.39 340 24.02 610 6.23 160 13967
4 Rows of 18 Modules 13.39 340 33.15 842 6.23 160 13968
Table 67: Kaedra Weatherproof Enclosure Accessories
Description Cat. No.
Association Kit (2 Sleeves + 4 Nuts + 4 Washers) 13934
Blanking Plate (Set of 10 x 5 Modules) 13940
Sealing Kit (2 Screws, 5 Fasteners) 13947
Keylock (Eurolock no. 850) 13948
Plain Front Plate, 12 Modules 13944
Plain Front Plate, 18 Modules 13945
Cable Gland, PG11 (0.732 in./18.6 mm) 83992
Cable Gland, PG13.5 83993
Cable Gland, PG16 (0.886 in./22.5 mm) 83994
Cable Gland, PG21 (1.114 in./28.3 mm) 83995
Cable Gland, PG29 (1.457 in./37 mm) 83996
Cable Gland, PG36 (1.85 in./47 mm) 83997
™
Multi 9™ System Catalog
Section 7—Dimensions
66
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Section 7—Dimensions
UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers
Figure 43: UL 489/CSA C22.2 No.5 Listed C60 240 Vac
Circuit Breaker with Box Lug Terminals
Figure 44: UL 489/CSA C22.2 No.5 Listed C60 240 Vac
Circuit Breaker with Ring Tongue Terminals
Figure 45: UL 489/CSA C22.2 No.5 C60 480 Vac and 240
Vac Circuit Breaker with Fingersafe Shields
1.73
(44)
2.76
(70)
0.22
(5.5)
1.77
(45.1)
Clearance
0.63
(16)
2.13
(54)
1.42
(36)
0.71
(18)
1.22
(31.1)
2.08
(52.9)
2.13
(54.1)
4.21
(107)
1.22
(31.1)
08603364
1.73
(44)
2.76
(70)
0.22
(5.5)
1.77
(45.1)
0.63
(16)
2.13
(54)
1.42
(36)
0.71
(18)
1.54
(39.2)
2.41
(61.2)
2.45
(62.2)
4.86
(123.4)]
1.54
(39.2)
08603365
0.71
(18)
1.73
(44)
2.76
(70)
0.22
(5.5)
5.59
(142)
1.77
(45)
0.63
(16)
1.42
(36)
2.13
(54)
08603427
Dimensions: in.
(mm)
™
Multi 9™ System Catalog
Section 7—Dimensions
67
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
UL 1077 Supplementary Protectors
IEC Rated Circuit Breakers
Figure 46: C60 UL 1077 Supplementary Protectors
0.71
(18)
1.73
(44)
2.76
(70)
0.22
(5.5)
3.19
(81)
1.77
(45)
0.63
(16)
1.42
(36)
2.13
(54)
2.83
(72)
Dimensions: in.
(mm)
Figure 47: IEC N40 Circuit Breaker Figure 48: C60 IEC Circuit Breakers
Figure 49: C120 IEC Circuit Breaker
3.19
(81)
0.71
(18)
2.76
(70)
1.73
(44)
0.63
(16)
0.22
(95.5)
1.77
(45)
08603217
0.71
(18)
1.73
(44)
2.76
(70)
0.22
(5.5)
3.19
(81)
1.77
(45)
0.63
(16)
1.42
(36)
2.13
(54)
2.83
(72)
1.06
(27)
1.73
(44)
2.76
(70)
0.22
(5.5)
3.19
(81)
1.77
(45)
0.63
(16)
2.13
(54)
3.19
(81)
4.25
(108)
Dimensions: in.
(mm)
™
Multi 9™ System Catalog
Section 7—Dimensions
68
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
UL and IEC Rated Ground-Fault Products
Figure 50: UL GFP Ground-Fault Protector and IEC ID Residual Current Switch
1.73
(44)
2.72
(69)
0.24
(6)
3.19
(81)
1.77
(45)
0.59
(15)
1.42
(36)
2.83
(72)
08603221
4-pole
2-pole
Figure 51: IEC Vigi Ground-Fault Module for C60 Devices
1.73
(44)
2.76
(70)
0.22
[5.5]
1.77
(45)
0.94
(24)
0.63
(16)
3.43
[87]
3.43
(87)
1.06
(27)
2.12
(54)
08603512
3-, 4-pole
2-pole 1.42
(36)
2.48
(63)
3-, 4-pole
2-pole
25 A 63 A
Figure 52: IEC Vigi Ground-Fault Module for C120 Devices
3-, 4-pole
2-pole
1.73
(44)
2.76
(70)
0.22
(5.5)
3.19
(81)
1.77
(45)
0.63
(16)
2.13
(54)
4.25
(108)
08603461
Dimensions: :in.
(mm)
™
Multi 9™ System Catalog
Section 7—Dimensions
69
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Accessory Dimensions
Figure 53: OF Auxiliary Switch, SD Alarm Switch, MN
Undervoltage Release and MX + OF Shunt Trip
with Auxiliary Switch for C60 and C120
Figure 54: OFS Auxiliary Switch and Adapter for GFP
Ground-Fault Protector and ID Residual
Current Switch
Figure 55: TM Motor Operator for C60 Devices Figure 56: Spacer for C60 and C120 Devices
Figure 57: Interphase Barriers for C60 Devices Figure 58: Terminal Screw Shield for UL 489A, UL 1077
and IEC C60 Devices
0.35
(9) 1.73
(44)
2.68
(68)
0.22
(5.5)
1.77
(45)
0.63
(16)
0.71
(18)
3.35
(85)
3.31
(84)
08603187
OF
SD
and
MX
MN
and
C60 or C120
08603422
.35
(9) .24
(6)
2.4
(60.5)
1.7
(44)
3.0
(76)
3.5
(88)
1.8
(45)
1.73
(44)
2.95
(75)
0.24
(6)
3.19
(81)
3.19
(81)
1.77
(45)
2.48
(63)
4.61
(117)
3-, 4-pole
1-, 2-pole
08603527
1.38
(35)
0.59
(15)
1.77
(45)
0.63
(16)
0.35
(9)
0.75
(19)
1.77
(45)
4.21
(107)
08603425
2.76
(70)
0.22
(5.5)
3.19
(81)
0.79
(20)
0.79
(20)
6.02
(153)
1.42
(36)
1.73
(44)
2.13
(54)
2.83
(72)
08603117
0.37
(9.5)
2.76
(70)
1.73
(44)
0.22
(5.5)
3.19
(81)
4.13
(105)
2.83
(72)
0.37
(9.5)
08603116
Dimensions: :in.
(mm)
™
Multi 9™ System Catalog
Section 7—Dimensions
70
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Figure 59: Plug-In Base for UL 489A, UL 1077 and
IEC C60 Devices
Figure 60: Terminal Cover for UL 489A, UL 1077 and
IEC C60 Devices
0.71
(18)
2.68
(68)
6.93
(176)
6.54
(166) 0.69
(17.5)
0.69
(17.5)
08603239
2.76
(70)
1.93
(49)
0.22
(5.5)
3.19
(81)
1.42
(36)
1.42
(36)
2.83
(72)
6.02
(153)
08603188
Figure 61: Front Mounting Bracket Kit
Dimension A
No. of
Poles in. mm Catalog
No.
Bracket for C60 (18 mm/pole)
1
2
3
4
0.75
1.46
2.32
2.87
19
37
55
73
MG26983
MG26984
MG26985
MG26989
Bracket for C120 (27 mm/pole)
1
2
3
4
1.10
2.16
3.23
4.29
28
55
82
109
MG26986
MG26987
MG26988
MG26990
1.38
(35)
0.69
(17.5)
0.40
(10)
0.40
(10)
2.17
(55)
A
08603238
MERLINGERIN
multi 9
C60N
63A-type C
480Vac
IEC
O-OFF
O-OFF
O-OFF
Cat. No. 24474
R
For 5/32 in.
(4 mm)
Self-tapping
Terminal Screw Shields
Machine
Screw
Dimensions: :in.
(mm)
Figure 62: Rotary Handle for C60 Devices
6.41–13.0
(163–330) 1.73
(44)
3.35
(85)
08603592
1.18–8.27
(30–210)
4.45
(113)
0.51
(13)
1.97
(50)
0.39
(10)
0.73
(18.5)
Front Rotary Handle Lateral Rotary Handle
Dimensions: in.
(mm)
™
Multi 9™ System Catalog
Section 7—Dimensions
71
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Figure 63: Comb Bus Bar Dimensions
0.7
(18)
0.15
(3.8)
7.8
(198)
0.5
(13)
0.6
(1.5)
0.87
(22)
1.4
(35)
8.5
(216)
0.44
(11.2)
08603408
Dimensions: :in.
(mm)
Figure 64: Multi 9 UL C60 Mounting Base
3 (75)
Dimensions: inches (mm)
8.9 (225)
5.1 (130)
B
Number of Poles A B
12 5 (127) 10.2 (258)
24 9.2 (235) 14.4 (366)
36 13.5 (343) 18.7 (474)
48 17.7 (451) 23 (582)
60 22 (559) 27.2 (690)
Terminal studs 1/4 - 20
0.33 (8.5)
.8 (21)
2.3 (58)
1.1 (29)
1.3 (33) 2.2 (56)
.5 (13)
4.7 (120)
1.9 (49)
A
Dimensions: in.
(mm)
™
Multi 9™ System Catalog
Section 7—Dimensions
72
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Figure 65: IEC MSC Chassis for C60 Devices
0.87
(22)
0.47
(12)
0.24 x 0.47
(6 x 12)
4x
6x
3.72
(94.5)
5.91
(150)
8.43
(214)
0.39
(10)
0.91
(23)
0.91
(23)
1.77
(45)
0.59
(15)
1.42
(36)
7.64
(194)
5.79
(147)
2.34
(59.5)
2.34
(59.5)
1.38
(35)
1.38
(35)
0.35
(9)
0.71
(18)
0.26
(6.5)
A
X
X
Section X-X
Miniature Circuit Breaker
DIN Rail
B
C=
08603621
=
User
Provided
Panel
C
LC
L
C
L
C
L
1
C
L
1
C
L
2
12
2
Dimensions: :in.
(mm)
Table 68: MSC Chassis for C60 Devices
Type Number of Poles
Dimensions
A1BC
in. mm in. mm in. mm
MSC DC
(for C60 2 pole)
12
16
20
11.7
13.2
14.6
299
335
371
4.33
5.75
7.17
110
146
182
2.13
3.54
4.57
54
90
116
MSC 18
(for C60 3 pole)
12
18
24
11.7
13.9
15.9
299
353
405
4.33
6.46
8.58
110
164
218
15.9
8.58
6.38
405
218
162
MSC 27
(for C120 3 pole)
12
18
24
17.0
21.7
26.5
432
551
673
9.57
14.35
19.13
162
243
324
4.25
7.44
10.63
108
189
270
1For TF suffix (top feed only), reduce length by 3.72 in. (94.5 mm).
™
Multi 9™ System Catalog
Section 7—Dimensions
73
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Figure 66: Multi-Pole Front Mounting Kit for C60 Devices
Figure 67: Bracket for Front Mounting Kit Figure 68: M9PF4 Pole Filler
08603522
R =
12 Ø
7.28
(185)
4.96
(126)
3.74
(95)
0.75
(19)
9.25
(235)
2.24
(57)
2.24
(57)
4.11
(104.5]
4.11
(104.5)
4.00
(101.5)
4.00
(101.5)
2.17
(55)
2.17
(55)
3.78
(96)
7.32
(186)
0.20
(5)
0.08
(2)
1.59
(40.5) 1.26
(32)
1.26
(32)
1.59
(40.5)
08603424
8.2
(209)
4 Ø .16
(4)
2.9
(74)
3.2
(81)
2.5
(64)
8.0
(203)
0.71
(18)
2.83
(72)
2.01
(51)
1.77
(45)
.20
(5)
08603585
Figure 69: SPD Surge Protectors
2.80
(71]
3.39
(86)
2.56
(65)
1.77
(45)
3.62
(92)
2-Pole Front
1-Pole Front
Optional
Connector
1-Pole Side 2- and 4-Pole Side
4-Pole Front
1.77
(45)
2.56
(65)
1.77
(45)
3.39
(86)
3.62
(92)
2.57
(67)
2.57
(67)
3.50
(89)
1.42
(36)
0.71
(18)
3.74
(95)
Optional
Connector
08603586
Dimensions: in.
(mm)
™
Multi 9™ System Catalog
Section 7—Dimensions
74
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Figure 70: CM Switches Figure 71: I Switch (20–32 A)
Figure 72: I Switch (40–125 A) Figure 73: V Signal Lamps
Figure 74: BP Push Buttons Figure 75: CH Hour Counter
Figure 76: CI Impulse Counter
1.57
(40)
2.36
(60)
0.39
(10)
0.22
(5.5)
1.77
(45)
0.71
(18)
3.23
(82)
1.42
(36)
08603234
1-circuit 2-circuit
1.57
(40)
2.76
(70)
0.22
(5.5)
1.77
(45)
0.71
(18)
3.03
(77)
1.42
(36)
08603299
2.76
(70)
0.22
(5.5)
3.23
(82)
0.71
(18)
1.77
(45)
1.42
(36)
1.57
(40)
2.13
(54)
2.83
(72)
2.36
(60)
08603230
1.57
(40)
2.36
(60)
0.16
(4)
0.22
(5.5)
1.77
(45)
0.71
(18)
3.23
(82)
08603232
Dimensions: :in.
(mm)
1.57
(40)
2.36
(60)
0.24
(6)
0.22
(5.5)
1.77
(45)
0.71
(18)
3.23
(82)
08603233
1.46
(37)
2.56
(65)
0.24
(6)
1.77
(45)
3.23
(82)
1.42
(36)
08603236
1.73
(44)
2.36
(60)
0.20
(5)
1.77
(45)
3.23
(82)
1.42
(36)
08603235
Dimensions: in.
(mm)
™
Multi 9™ System Catalog
Section 7—Dimensions
75
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Kaedra Weatherproof Mini-Enclosure Dimensions
Table 69: Kaedra Weatherproof Mini-Enclosure Dimensions
No. of
Modules
LHWeight
Cat. No.
in mm in mm lbs grams
3 3.1 80 5.9 150 0.66 300 13956
4 4.8 123 7.9 200 0.99 450 13957
6 6.3 159 7.9 200 1.32 600 13958
8 7.7 195 7.9 200 1.76 800 13959
12 10.5 267 7.9 200 1.98 900 13960
Figure 77: Kaedra Weatherproof Mini-Enclosures
5.51
(140)
1.18
(30)
5.51
(140)
1.18
(30)
1.71
(43.5)
1.40
(35.5)
2.76
(70)
4.40
(111.5)
1.87
(47.5)
1.71
(43.5)
1.55
(39.3)
0.90
(22.8)
0.73
(18.5)
0.14
(3.5)
08603587
Dimensions: :in.
(mm)
Figure 78: Top View for Kaedra Weatherproof Type Mini Enclosures
.83
(21)
.67
(17)
.67
(17)
4.13
(105)
08603588
4.84
(123)
.67
(17] .74
(18,5)
.85
(21,5) .85
(21,5)
.83
(21)
.83
(21)
.83
(21) .83
(21)
1.14
(29)
.91
(23)
2.56
(65]
7.70
(195)
.91
(23)
.91
(23)
.91
(23)
.91
(23)
.91
(23)
1.14
(29)
1.14
(29)
.91
(23)
6.25
(159)
.74
(18,5) .74
(18,5)
.74
(18,5)
10.5
(267)
.85
(21,5)
1.77
(45)
1.77
(45)
[37,5]
.83
(21)
.83
(21)
1.14
(29)
1.14
(29)
1.14
(29)
.91
(23)
.91
(23)
.85
(21,5]
1.38
(35)
2.56
(65)
2.56
(65)
1.38
(35)
1.67
(42,5)
1.67
(42,5)
2.95
(75)
2.95
(75)
1.06
(27)
1.00
(25,5)
3 Modules 4 Modules 6 Modules 8 Modules
12 Modules
Dimensions: :in.
(mm)
™
Multi 9™ System Catalog
Section 7—Dimensions
76
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Kaedra Weatherproof Enclosures
Table 70: Kaedra Weatherproof Enclosure Dimensions (12 Module)
A B C Weight Cat. No.
in mm in mm in mm lbs grams
11.02 280 4.65 118 3.19 81 4.19 1900 13962
18.11 460 9.88 251 4.15 104.5 7.28 3300 13964
24.02 610 15.79 401 4.15 104.5 9.04 4100 13968
Figure 79: Kaedra Weatherproof Type Enclosures (12 Module)
08603589
13.39
(340)
7.01
(178)
1.26
(32) (*)
7.01
(178)
4.69
(119)
4.69
(119)
4.17
(106)
4.17
(06)
3.62
(92)
3.62
(92)
2.52
(64)
2.52
(64)
.67
(17)
1.46
(37)
2.83
(72)
2.36
(60)
.73
(18,6)
.73
(18,6)
.88
(22,5)
1.73
(44)
1.06
(27)
1.26
(32)
1.46
(37)
5.51
(140)
5.51
(140)
.88
(22,5)
1.11
(28,3)
1.11
(28,3)
1.26
(32)
Front View Side View Side View
Dimensions: :in.
(mm)
Table 71: Kaedra Weatherproof Enclosure Dimensions (18 Module)
A B C Weight Cat. No.
in mm in mm in mm lbs grams
11.02 280 4.65 118 3.19 81 5.29 2400 13963
18.11 460 9.88 251 4.15 104.5 9.04 4100 13965
24.02 610 15.79 401 4.15 104.5 12.35 5600 13967
33.15 842 24.92 633 4.15 104.5 14.55 6600 13968
Figure 80: Kaedra Weatherproof Type Enclosures (18 Module)
08603590
7.01
(178)
17.64
(448)
7.76
(194)
7.76
(194)
1.26
(32) (*)
7.01
(178)
1.85
(47)
3.19
(81)
4.65
(118)
6.30
(160)
6.65
(169) 6.65
(169)
6.30
(160)
4.65
(118)
3.19
(81)
1.85
(47)
.73
(18,6)
1.06
(27)
1.26
(32)
2.76
(70)
.88
(22,5)
.88
(22,5)
1.11
(28,3)
1.45
(37)
1.85
(47)
1.11
(28,3)
1.11
(28,3)
1.26
(32)
Front View Side View Side View
Dimensions: :in.
(mm)
™
Multi 9™ System Catalog
Section 7—Dimensions
77
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Table 72: Kaedra Cable Glands for Weatherproof Enclosures
Cable Size Drilling Diameter Thread Diameter Pre-Punchout Cat. No.
in mm in mm mm mm
0.354–0.433 9–11 0.740 18.8 18.6 PG 11 83992
0.354–0.472 9–12 0.815 20.7 20.4 PG 13.5 83993
0.394–0.512 10–13 0.898 22.8 22.5 PG 16 83994
0.551–0.669 14–17 1.125 28.6 28.3 PG 21 83995
0.748–1.024 19–26 1.472 37.4 37 PG 29 83996
1.102–1.417 28–36 1.870 47.5 47 PG 36 83997
Figure 81: Kaedra Horizontal Side-by-Side Interconnection References
1.26 in
(32 mm)
Ø
3.98
(101) 4.65
(118)
4.65
(118)
4.65
(118)
4.65
(118)
4.49
(114)
4.49
(114)
3.3
(84)
4.65
(118)
4.65
(118)
33.15
(842]
24.02
(610)
18.11
(460)
2.44
(62)
2.60
(66)
2.60
(66)
2.44
(62)
2.44
(62)
3.46
(88)
11.02
(280)
4.65
(118)
3.98
(101)
7.09
(180)
13.19
(335)
3.98
(101)
3.98
(101)
3.19
(81)
3.19
(81)
3.05
(77,5)
3.19
(81)
3.19
(81)
08603591
2 Modules 4 Modules
6 Modules
8 Modules
12 Modules
Dimensions: :in.
(mm)
™
Multi 9™ System Catalog
Section 8—Applications
78
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Section 8—Applications
Degree of Protection (IP)
The IEC 529 Standard publication or the European EN 60529 Standard define the IP degree of
protection characterizing the ability of a device to withstand the two external influences below:
•
Ingress of solid bodies and protection of people
•
Ingress of water
The IP contains two digits, one for each of these external influences, and is assigned to the device
after a series of tests defined by the NF EN 60529 Standard. The IP degree of protection must always
be read and understood digit by digit and not globally. The two IP digits may contain an optional letter
which indicates the enclosure’s ability to protect people against access to live parts.
The degrees of protection given in this catalog apply for enclosures as described here. However, the
initial degree of protection can only be maintained if the device is properly assembled and installed.
Class 2: The term “double insulation” is also used. This consists of backing up the main insulation of an
electrical device by an additional insulation in order to protect people against direct contact.
Table 73: Explanation of IP Degree of Protection Digits
1
1When mounted outdoors, the IP
≥
54 enclosures must be equipped with a protectable top, or installed in a shelter.
First Digit
Solid Body Protection
Second Digit
Liquid Protection
Third Digit
Mechanical Protection
IP Tests IP Tests IP Tests IK
0 No protection 0 No protection 0 No protection 00
1
Protected against solid
bodies larger than 1.97 in.
(50 mm), e.g., accidental
hand contact
1
Protected against
vertically falling water
droplets
(condensation)
1Impact energy
0.225 joules 02
2
Protected against solid
bodies larger than 0.47 in.
(12 mm), e.g., fingers
2
Protected against
falling water droplets
up to 15° from vertical
3Impact energy
500 joules 04
3
Protected against solid
bodies larger than 0.098 in.
(2.5 mm), e.g., tools, wires
3
Protected against
rainwater up to 60°
from vertical
5Impact energy
2.00 joules 07
4
Protected against solid
bodies larger than 0.039 in.
(1 mm), e.g., fine tools, small
wires
4
Protected against
water spray from all
directions
7Impact energy
6.00 joules 08
5Protected against dust (no
harmful deposit) 5
Protected against
water splashes from
all directions by jet
pipes
9
Impact energy
20.00 joules 10
6Completely protected against
dust 6
Protected against
water splashes/waves
(of the heavy sea kind)
7Protected against
immersion effects
(50 mm)
1.97 in
Ø
08603562
08603563
(12.5 mm
0.492 in.
X
~
Ø
08603564
15°
08603565
(12.5 mm
0.492 in.
X
~
Ø
08603564
60°
08603567
(1 mm)
0.039 i
n
Ø
08603568
08603570
08603573
08603575
08603576
™
Multi 9™ System Catalog
Section 8—Applications
79
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Vibration
Mechanical Shock (IK)
As per IEC 68.2.27 Standard: 1.06 oz./30 g, 18 ms., 3 shocks per axis.
Standard EN 50.102 defines an IK code characterizing the ability of a device to withstand mechanical
shocks. The IK code replaces the third digit of the old IP.
Protection of 400 Hz Circuits
The C60 and C120 miniature circuit breakers are designed to be applied on 50/60 Hz systems and can
be re-rated for use on 400 Hz systems.
•
Thermal: No variation
•
Magnetic increase in thresholds multiplier:
— N40: 1.50
— C60N: 1.48
— C120H: 1.40
Vigi ground-fault modules and residual current circuit breakers and switches can also be used on 400
Hz systems. Note in Figure 82 that the mA threshold varies according to system frequency.
Table 74: Vibration as per IEC 68.2.6 Standard
1
1Results depend on magnetic trip level. Five frequency sweeps per axis.
Curve Sequence Vibration
Curve B Sequence S3: 0.14 oz. (4 g) 5–13 Hz: ±0.24 in. (6 mm)
13–300 Hz: 0.14 oz. (4 g)
Curve C and D Sequence S6: 0.25 oz. (7 g) 5–58 Hz: ±0.02 in. (0.5 mm)
58–300 Hz: 0.25 oz. (7 g)
Table 75: 400 Hz Circuits
Type No. of Poles
Interrupting Ratings (Vac)
240 277 480Y/277
C60N
(0.5–63 A)
1P
2P, 3P and 4P
4,000
4,000
3,000
—
—
3,000
C120H (50–80 A) 1P
2P, 3P and 4P
3,000
3,000
—
—
—
—
C120H (10–40 A) 1P
2P, 3P and 4P
5,000
5,000
4,000
—
—
4,000
™
Multi 9™ System Catalog
Section 8—Applications
80
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Temperature Rating
The operating current of the circuit breakers varies depending on the ambient temperature in
which the circuit breaker is located.
If the circuit breaker is installed in an enclosure or in a hot room (boiler room, etc.), the current needed
to trip the circuit breaker in the event of an overload will be lower. If the ambient temperature exceeds
the circuit breaker’s reference temperature, the supplementary protective device or the circuit breaker
will then be “derated”. That is why circuit breaker manufacturers supply tables showing the derated
current (A) to be applied for given temperatures. NB: In the event of an ambient temperature less than
the rated temperature, the supplementary protective device or the circuit breaker is “uprated”.
Moreover, when several circuit breakers operating simultaneously are mounted side by side in
a small enclosure, the temperature rise inside the enclosure entails a reduction in the operating
current.
This mutual temperature rise in theory requires the application of an additional derating factor of 0.8.
Table 76: Curve Sensitivity at 400 Hz
Class Rating
(A)
Curve No. Sensitivity (mA)
10 30 100 300
N40 Residual Current Circuit Breakers
AC
≤
25 —
C60 Vigi Ground-Fault Module
110/220 V, 50 Hz Vigi C60
AC
≤ 25 —
≤ 63 — —
2P, 3P, 4P 220/415 V, 50 Hz Vigi C60
AC
≤ 25 —
≤ 63 — —
AC —
C120 Vigi Ground-Fault Module
AC ≤ 100 — —
AC ≤ 100 —
ID Residual Current Switch
AC
25 —
25–40 —
63–80–100 —
AC 63–80–100 — — —
0.5
1.5
10 50 60 Hz90 150 250 350
1
2
2.5
400
IΔn
0.5
1.5
10 50 60 Hz90 150 250 350
1
2
2.5
400
IΔn
0.5
1.5
10 50 60 H
z
90 150 250 350
1
2
2.5
400
IΔn
0.5
1.5
10 50 60 Hz90 150 250 350
1
2
2.5
400
IΔn
08603574
1
11
1
2
2
2
3
3
DPN-N Residual Current Circuit Breaker C60 VIGI Ground-fault Module
NC100 VIGI Ground-fault Module ID Residual Current Switch
Figure 82: Protection of 400 Hz Circuits
1
1
1
2
1
1
2
1
2
1
1
2
1
s
3
2
2
3
1
s
2
2
2
2
1
1
1
1
1
2
1
1
s
2
™
Multi 9™ System Catalog
Section 8—Applications
81
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
NOTE: The UL 489/CSA C22.2 No.5 Listed Multi 9 C60 circuit breakers are calibrated at 77°F (25°C),
unlike some other UL 489/CSA 22.2 No.5 circuit breakers which are calibrated at 104°F (40°C).
Depending on the operating environment, you may need to rerate according to these tables to
determine the appropriate handle rating.
NOTE: UL 489/CSA C22.2 No.5 Listed circuit breakers should be loaded to no more than 80% if used
with continuous loads.
Table 77: Rated Temperatures for UL Listed Circuit Breakers and UL Recognized C60 Supplementary Protectors
(The reference temperature is in half-tone color.)
Rating
(A)
-22°F
-30°C
-13°F
-25°C
-4°F
-20°C
5°F
-15°C
14°F
-10°C
23°F
-5°C
32°F
0°C
41°F
5°C
50°F
10°C
59°F
15°C
68°F
20°C
77°F
25°C
86°F
30°C
104°F
40°C
122°F
50°C
140°F
60°C
158°F
70°C
0.5
1
1.2
1.5
1.26
1.21
1.26
1.32
1.24
1.19
1.24
1.29
1.22
1.18
1.22
1.27
1.20
1.16
1.20
1.24
1.17
1.14
1.17
1.21
1.15
1.12
1.15
1.19
1.13
1.10
1.13
1.16
1.10
1.08
1.10
1.13
1.08
1.06
1.08
1.10
1.05
1.04
1.05
1.07
1.03
0.02
1.03
1.03
1.00
1.00
1.00
1.00
0.97
0.98
0.97
0.97
0.92
0.93
0.92
0.89
0.85
0.89
0.85
0.81
0.79
0.84
0.79
0.73
0.72
0.79
0.72
0.63
2
3
4
5
1.21
1.27
1.25
1.26
1.19
1.25
1.23
1.24
1.18
1.22
1.21
1.22
1.16
1.20
1.19
1.19
1.14
1.18
1.17
1.17
1.12
1.15
1.15
1.15
1.10
1.13
1.12
1.13
1.08
1.11
1.10
1.10
1.06
1.08
1.07
1.08
1.04
1.05
1.05
1.05
1.02
1.03
1.03
1.03
1.00
1.00
1.00
1.00
0.98
0.97
0.97
1.97
0.93
0.91
0.92
0.92
0.89
0.85
0.86
0.86
0.84
0.78
0.80
0.79
0.79
0.71
0.73
0.72
6
7
8
10
1.23
1.29
1.29
1.28
1.21
1.26
1.26
1.25
1.19
1.24
1.24
1.23
1.17
1.22
1.22
1.21
1.15
1.19
1.19
1.18
1.13
1.17
1.17
1.16
1.11
1.14
1.14
1.13
1.09
1.11
1.11
1.11
1.07
1.09
1.09
1.08
1.05
1.06
1.06
1.06
1.02
1.03
1.03
1.03
1.00
1.00
1.00
1.00
0.98
0.97
0.97
0.97
0.93
0.91
0.91
0.91
0.87
0.84
0.84
0.85
0.82
0.76
0.76
0.78
0.76
0.68
0.68
0.70
13
15
16
20
1.20
1.28
1.24
1.23
1.18
1.25
1.22
1.21
1.16
1.23
1.20
1.19
1.15
1.21
1.18
1.17
1.13
1.18
1.16
1.15
1.11
1.16
1.14
1.13
1.09
1.13
1.11
1.11
1.08
1.11
1.09
1.09
1.06
1.08
1.07
1.07
1.04
1.06
1.05
1.05
1.02
1.03
1.02
1.02
1.00
1.00
1.00
1.00
0.98
0.97
0.98
0.98
0.94
0.91
0.93
0.93
0.90
0.85
0.87
0.87
0.85
0.78
0.81
0.82
0.80
0.70
0.75
0.76
25
30
32
35
1.24
1.30
1.23
1.31
1.22
1.27
1.21
1.29
1.20
1.25
1.19
1.26
1.18
1.22
1.17
1.23
1.16
1.20
1.15
1.21
1.14
1.17
1.13
1.18
1.11
1.15
1.11
1.15
1.09
1.12
1.09
1.12
1.07
1.09
1.07
1.09
1.05
1.06
1.04
1.06
1.02
1.03
1.02
1.03
1.00
1.00
1.00
1.00
0.98
0.97
0.98
0.97
0.93
0.90
0.93
0.90
0.87
0.83
0.88
0.82
0.81
0.75
0.82
0.74
0.75
0.66
0.77
0.64
40
50
60
63
1.23
1.23
1.29
1.27
1.21
1.21
1.27
1.25
1.19
1.19
1.24
1.22
1.17
1.17
1.22
1.20
1.15
1.15
1.19
1.18
1.13
1.13
1.17
1.15
1.11
1.11
1.14
1.13
1.09
1.09
1.11
1.11
1.07
1.07
1.09
1.08
1.05
1.05
1.06
1.05
1.02
1.02
1.03
1.03
1.00
1.00
1.00
1.00
0.98
0.98
0.97
0.97
0.93
0.93
0.90
0.91
0.88
0.88
0.84
0.85
0.82
0.82
0.76
0.78
0.76
0.76
0.67
0.71
Table 78: Rated Temperatures for IEC Rated N40 Circuit Breakers
Ampere
Rating (A)
68°F
20°C
77°F
25°C
86°F
30°C
95°F
35°C
104°F
40°C
113°F
45°C
122°F
50°C
131°F
55°C
140°F
60°C
1
2
3
6
1.04
1.04
1.04
1.04
1.02
1.02
1.02
1.02
1.00
1.00
1.00
1.00
0.98
0.98
0.97
0.98
0.96
0.96
0.94
0.96
0.93
0.94
0.92
0.93
0.91
0.91
0.89
0.91
0.89
0.89
0.86
0.89
0.86
0.86
0.82
0.86
10
16
20
25
1.05
1.05
1.05
1.04
1.03
1.02
1.02
1.02
1.00
1.00
1.00
1.00
0.97
0.98
0.98
098
0.95
0.95
0.95
0.95
0.92
0.93
0.93
0.93
0.89
0.90
0.90
0.91
0.86
0.87
0.88
0.88
0.83
0.85
0.85
0.86
32
40
1.05
1.05
1.03
1.03
1.00
1.00
0.97
0.97
0.95
0.95
0.92
0.92
0.89
0.89
0.86
0.86
0.83
0.83
™
Multi 9™ System Catalog
Section 8—Applications
82
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Table 79: Rated Temperature for IEC Rated C60H (C Curve) and C60L (B and C Curve) Circuit Breakers
Ampere
Rating (A)
68°F
20°C
77°F
25°C
86°F
30°C
95°F
35°C
104°F
40°C
113°F
45°C
122°F
50°C
131°F
55°C
140°F
60°C
1
2
3
4
1.05
1.04
1.06
1.06
1.02
1.02
1.03
1.03
1.00
1.00
1.00
1.00
0.98
0.98
0.97
0.97
0.95
0.96
0.94
0.94
0.93
0.94
0.90
0.91
0.90
0.92
0.87
0.88
0.88
0.90
0.83
0.84
0.85
0.87
0.79
0.81
6
10
16
20
1.04
1.06
1.05
1.05
1.02
1.03
1.03
1.03
1.00
1.00
1.00
1.00
0.98
0.97
0.97
0.97
0.96
0.93
0.95
0.95
0.94
0.90
0.92
0.92
0.92
0.86
0.89
0.89
0.90
0.82
0.86
0.87
0.88
0.78
0.83
0.84
25
32
40
50
1.05
1.05
1.05
1.05
1.03
1.03
1.03
1.03
1.00
1.00
1.00
1.00
0.97
0.98
0.97
0.97
0.95
1.19
0.95
0.95
0.92
0.93
0.92
0.91
0.89
0.89
0.89
0.88
0.86
0.88
0.86
0.85
0.83
0.86
0.81
0.81
63 1.05 1.03 1.00 0.97 0.92 0.90 0.86 0.82 0.78
Table 80: Rated Temperatures for IEC Rated C60 (D Curve) and C60L (B, C, Z and K Curve) Circuit Breakers
Ampere
Rating (A)
68°F
20°C
77°F
25°C
86°F
30°C
95°F
35°C
104°F
40°C
113°F
45°C
122°F
50°C
131°F
55°C
140°F
60°C
1
2
3
4
1.10
1.09
1.14
1.13
1.08
1.07
1.10
1.10
1.05
1.04
1.07
1.06
1.03
1.02
1.04
1.03
1.00
1.00
1.00
1.00
0.97
0.98
0.96
0.97
0.95
0.95
0.92
0.93
0.92
0.93
0.88
0.89
0.89
0.90
0.84
0.86
6
10
16
20
1.08
1.14
1.12
1.11
1.06
1.11
1.09
1.08
1.04
1.07
1.06
1.06
1.02
1.04
1.03
1.03
1.00
1.00
1.00
1.00
0.98
0.96
0.97
0.97
0.96
0.92
0.94
0.94
0.93
0.88
0.90
0.91
0.91
0.84
0.87
0.88
25
32
40
50
1.11
1.10
1.11
1.12
1.08
1.07
1.09
1.09
1.06
1.05
1.06
1.06
1.03
1.03
1.03
1.03
1.00
1.00
1.00
1.00
0.97
0.97
0.97
0.97
0.94
0.95
0.94
0.93
0.91
0.92
0.91
0.90
0.87
0.89
0.87
0.86
63 1.14 1.11 1.07 1.04 1.00 0.96 0.92 0.88 0.84
Table 81: Rated Temperatures for IEC Rated C120 Circuit Breakers
Ampere
Rating (A)
68°F
20°C
77°F
25°C
86°F
30°C
95°F
35°C
104°F
40°C
113°F
45°C
122°F
50°C
131°F
55°C
140°F
60°C
10
16
20
25
1.10
1.06
1.13
1.08
1.07
1.03
1.10
1.06
1.05
1.00
1.05
1.04
1.03
1.00
1.03
1.02
1.00
1.00
1.00
1.00
0.95
0.97
0.95
0.96
0.90
0.94
0.93
0.92
0.87
0.91
0.90
0.90
0.85
0.88
0.85
0.88
32
40
50
63
1.13
1.14
1.15
1.15
1.09
1.10
1.12
1.12
1.06
1.08
1.08
1.08
1.03
1.04
1.04
1.04
1.00
1.00
1.00
1.00
0.97
0.96
0.96
0.96
0.92
0.93
0.91
0.91
0.88
0.88
0.87
0.87
0.84
0.84
0.82
0.82
80
100
125
1.15
1.15
1.12
1.11
1.12
1.10
1.08
1.08
1.08
1.04
1.04
1.04
1.00
1.00
1.00
0.96
0.96
0.96
0.92
0.92
0.90
0.87
0.87
0.86
0.83
0.83
0.82
™
Multi 9™ System Catalog
Section 8—Applications
83
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Typical IEC Grounding Systems
All electrical installations complying with safety standards and regulations are grounded in order to
protect people and equipment. The term “grounding system” standardizes the grounding method used
in the installation. The grounding system runs:
•
First, from the neutral of the secondary side of the transformer,
•
Next, from the installation frames.
The IEC 364 (Section 3) Standard defines three types of grounding systems: TT, IT and TN-C or TN-S.
Codification of the Grounding Systems
Grounding systems are referred to by two or three letters for example:
•
1st letter—Status of the neutral of the transformer or source:
— I: Ungrounded
— T: Grounded
•
2nd letter—Status of the electrical frames of the loads:
— T: Grounded
— N: Connected to neutral
•
3rd letter—Status of the neutral (N) and the protective conductor (PE):
— S: N and PE are separate
— C: N and PE are in the same conductor (PEN)
The TT Grounded Neutral System
This “directly-grounded neutral” system is the easiest to install, monitor and use. Main features are:
•
The neutral point of the distribution transformer is directly grounded.
•
The installation frames are connected to several ground connections by the PE protective
conductor.
•
The frame and neutral ground connections are separate.
System characteristics upon installation:
•
Tripping is compulsory on the first fault.
•
Thus, at least one RCD is necessary at the incoming end of the installation.
•
If the load frames are not all connected to the same grounding connection, one RCD must be
installed for each set of equipment.
Figure 83: TT Grounding Systems
T N S
1
2
3
N
RCD
PE
1
2
3
N
RCD
RCD RCD
PEPE
TT Grounding System with Residual Current
Device (RCD) at the Incoming End of the Installation
TT Grounding System with One Residual
Current Device (RCD) for Each Set of Equipment
08603271
™
Multi 9™ System Catalog
Section 8—Applications
84
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
The IT Grounding System
This “ungrounded neutral” system has the following main features:
•
The neutral point of the distribution transformer is ungrounded, or grounded by a high impedance.
•
The installation frames are connected to the same grounding connection by the PE protective
conductor.
System characteristics and constraints upon installation:
•
The appearance of the first insulation fault is risk-free for people.
•
The appearance of the second insulation fault is dangerous to people, and thus requires tripping.
•
If the application frames and the transformer frame are not all connected to the same ground
connection, an RCD must be placed at the incoming end of the installation.
•
The standard stipulates the installation of a Continuous Insulation Monitor (CIM) at the incoming
end of the installation.
The TN-S Grounding System
This “multiple-grounded neutral” system has the following main features:
•
The neutral point of the distribution transformer is grounded.
•
All installation frames are grounded by a PE protective conductor.
•
The PE protective conductors and the N neutral conductor are separate.
System characteristics and constraints upon installation:
•
Allows tripping on the first fault via an overcurrent protection device.
•
Use of an RCD, although not compulsory, is recommended.
•
Requires calculation, sometimes complex, of loop impedance.
•
Tripping of the protection devices must be checked when these devices are installed, B curve is
recommended.
NOTE: This grounding system is compulsory on premises where there is a risk of explosion.
Figure 84: IT Grounding Systems
Figure 85: TN-S Grounding System
1
2
3
N
PE
CIM
1
2
3
N
PE
PE
RCD
CIM
IT Grounding System Without Residual Current Device (RCD) IT Grounding System With Residual Current
Device (RCD) at the Incoming End of the Installation
08603273
1
2
3
N
PE
08603275
™
Multi 9™ System Catalog
Section 9—Time/Current Curves
85
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Section 9—Time/Current Curves
UL 489/CSA C22.2 No. 5 and UL 489A Listed C60 Miniature Circuit
Breakers
Figure 86: UL 489/CSA C22.2 No.5 Listed C60—C Curve
(0.5–35 A) AC & DC
Figure 87: UL 489/CSA C22.2 No.5 Listed C60—D Curve
(0.5–35 A) AC
Figure 88: UL 489/CSA C22.2 No.5 Listed C60—C Curve
(0.5–35 A) DC
™
Multi 9™ System Catalog
Section 9—Time/Current Curves
86
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
UL 1077 Recognized Supplementary Protectors
1
1Dotted Line is the tripping limit of a single pole of multi-pole device.
Figure 89: UL 1077 Recognized C60—B Curve Figure 90: UL 1077 Recognized C60—C Curve
Figure 91: UL 1077 Recognized C60—D Curve
™
Multi 9™ System Catalog
Section 9—Time/Current Curves
87
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
IEC60947-2 Rated D PN-N Circuit Breakers
Table 82: DPNa/N
According to IEC/EN 6098 (Reference Temperature 30°C)
Curves B, C, D
™
Multi 9™ System Catalog
Section 9—Time/Current Curves
88
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Alternative Current 50/60 Hz
Table 83: C60N/H/L
According to IEC/EN 60947-2 (Reference Temperature 50°C)
Curves B, C, D Rating up to 4 A Curves Z, K Rating up to 4 A
Curves B, C, D Rating 6 A to 63 A Curves Z, K Rating 6 A to 63 A
™
Multi 9™ System Catalog
Section 9—Time/Current Curves
89
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Motor Curve
Table 84: C60L-MA
According to IEC/EN 60947-2
Curve MA
™
Multi 9™ System Catalog
Section 10—Let-Through Curves
90
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Section 10—Let-Through Curves
UL Listed C60 Miniature Circuit Breakers and UL Recognized C60
Supplementary Protectors
Figure 92: UL 489/CSA C22.2 No.5/489A Listed and UL
1077 Recognized C60 1P (240 Vac) Max Let-
Through Peak Current
Figure 93: UL 489/CSA C22.2 No.5/489A Listed and UL
1077 Recognized C60 1P (240 Vac) Max Let-
Through I
2
t Current
10
6
3
2
10
5
4
3
2
10
5
4
3
2
10
5
4
3
2
10
5
4
3
2
10
5
10
4
10
3
201087653210.2 0.80.60.50.40.3 4
A
2
S
kA RMS
6 A
10 A
25 A
40 A
63 A
08603207
™
Multi 9™ System Catalog
Section 10—Let-Through Curves
91
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Figure 94: UL 489/CSA C22.2 No.5 Listed and UL 1077
Recognized C60 2P, 3P, and 4P (240 Vac) Max
Let-Through Peak Current
Figure 95: UL 489/CSA C22.2 No.5 Listed and UL 1077
Recognized C60 2P, 3P, and 4P (240 Vac) Max
I
2
t Peak Current
™
Multi 9™ System Catalog
Section 10—Let-Through Curves
92
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Figure 96: UL 489/CSA C22.2 No.5 Listed and UL 1077
Recognized C60 1P (277 Vac) Maximum Let-
Through Peak Current
Figure 97: UL 489/CSA C22.2 No.5 Listed and UL 1077
Recognized C60 1P (277 Vac) Maximum I
2
t
Peak Current
Figure 98: UL 1077 Recognized C60 2P, 3P, and 4P
(480Y/277 Vac) Maximum Let-Through Peak
Current
Figure 99: UL 1077 Recognized C60 2P, 3P, and 4P
(480Y/277 Vac) Maximum Let-Through I²t
Current
™
Multi 9™ System Catalog
Section 10—Let-Through Curves
93
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Figure 100: UL 1077 Recognized C60 2P, 3P, and 4P
(480 Vac) Maximum Let-Through Peak Current
Figure 101: UL 1077 Recognized C60 2P, 3P, and 4P
(480 Vac) Maximum Let-Through I²t Current
3210.2
0.2
0.3
0.4
0.5
0.6
0.8
1
2
3
4
5
6
8
10
20
0.3 0.4 0.5 0.6 0.8 4 5 6 7 8 10 20
kA RMS
Maximum Peak Current
6 A
10 A
20 A
kA
08603459
106
3
2
1
0
5
4
3
2
1
0
5
4
3
2
1
0
5
4
3
2
1
0
5
4
3
2
105
104
103
201087653210.2 0.80.60.50.40.3 4
A2S
kA RMS
6 A
10 A
20 A
08603460
™
Multi 9™ System Catalog
Section 10—Let-Through Curves
94
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Limitation curves
For 230 V single-phase or 400 V three-phase network (TN or TT earthing system.
Table 85: Limitation Curves—C60N
1P / 3P / 4P Circuit Breakers
Peak Currents Thermal Stress
1P+N / 2P Circuit Breakers
Peak Currents Thermal Stress
™
Multi 9™ System Catalog
Section 10—Let-Through Curves
95
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
Table 86: Limitation Curves—C60H
1P / 3P / 4P Circuit Breakers
Peak Currents Thermal Stress
1P+N / 2P Circuit Breakers
Peak Currents Thermal Stress
™
Multi 9™ System Catalog
Section 10—Let-Through Curves
96
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Table 87: Limitation Curves—C60L
1P / 3P / 4P Circuit Breakers
Peak Currents Thermal Stress
1P+N / 2P Circuit Breakers
Peak Currents Thermal Stress
™
Multi 9™ System Catalog
Index
97
11/2014 © 2008–2014 Schneider Electric
All Rights Reserved
Index of Part Numbers
Numerics
13934
65
13940
65
13944
65
13945
65
13947
65
13948
65
13956
65
,
75
13957
65
,
75
13958
65
,
75
13959
65
,
75
13960
65
,
75
13962
65
,
76
13963
65
,
76
13964
65
,
76
13965
65
,
76
13966
65
13967
65
,
76
13968
65
,
76
14210
57
14211
57
14881
48
14882
48
14886
49
14891
48
14893
48
15005
60
15006
60
15007
60
15008
60
15009
60
15010
60
15102
59
15103
59
15129
59
15440
63
15443
63
17400
51
18030
62
18031
62
18032
62
18033
62
18034
62
18035
62
18036
62
18037
62
18038
62
18039
62
18320
61
–
62
18321
61
18322
61
18323
61
18324
61
18325
61
18326
61
18330
61
18333
61
18334
61
18335
61
18401
31
18402
31
18403
31
18404
31
18412
31
18413
31
18414
31
18415
31
18423
31
18424
31
18425
31
18426
31
18434
31
18435
31
18436
31
18437
31
18445
31
18456
31
18457
31
18458
31
18459
31
18467
31
18468
31
18469
31
18470
31
18478
31
18479
31
18480
31
18481
31
18489
31
18490
31
18491
31
18492
31
18500
31
18501
31
18502
31
18503
31
18511
31
18512
31
18513
31
18514
31
18522
31
18523
31
18524
31
18525
31
18556
39
18557
39
18558
39
18559
39
18560
39
18561
39
18591
39
–
40
,
42
18592
39
18593
39
18594
39
18595
39
18596
39
18597
39
18598
39
18599
39
26923
35
,
44
26924
42
26927
42
26970
52
26975
50
26976
50
26978
50
26981
50
,
54
26982
38
26996
54
27001
50
27046
52
27047
52
27048
52
27062
49
27105
42
27106
42
27107
42
27108
42
27109
42
27110
42
27118
42
27145
52
27152
54
60100
18
60101
18
60102
18
60103
18
60104
18
60105
18
60106
18
60107
18
60108
18
60109
18
60110
18
60111
18
60112
18
60113
18
60114
18
60115
18
60116
18
60117
18
60118
18
60119
18
60120
18
60121
18
60122
18
60123
18
60124
18
60125
18
60126
18
60127
18
60128
18
60129
18
60130
18
60131
18
60132
18
60133
18
60134
18
60135
18
60136
18
60137
18
60138
18
60139
18
60140
18
60141
18
60142
18
60143
18
60144
18
60145
18
60146
18
60147
18
60148
18
60149
18
60150
18
60151
18
60152
18
60153
18
60154
18
60155
18
60156
18
60157
18
60158
18
60159
18
60160
18
60161
18
60162
18
60163
18
60164
18
60165
18
60166
18
60167
18
60168
18
60169
18
60170
18
60171
18
60172
18
60173
18
60174
18
60175
18
60176
18
60177
18
60178
18
60179
18
60180
18
60181
18
60182
18
60183
18
60184
18
60185
18
60186
18
60187
18
60188
18
60189
18
60190
18
60191
18
60192
18
60193
18
60194
18
60195
18
60196
18
60197
18
60198
18
60199
18
60200
18
60201
18
60202
18
60203
18
60204
18
60205
18
60206
18
60207
18
60208
18
60209
18
60210
18
60211
18
60212
18
60213
18
60214
18
60215
18
60216
18
60217
18
60218
18
60219
18
60220
18
60221
18
60222
18
60223
18
60224
18
60225
18
60226
18
60227
18
60228
18
60229
18
60230
18
60231
18
60232
18
60233
18
60234
18
60235
18
60236
18
60237
18
60238
18
60239
18
60240
18
60241
18
60242
18
60243
18
60244
18
60245
18
60246
18
60247
18
60248
18
60249
18
60250
18
60251
18
60252
18
60253
18
60254
18
60255
18
60256
18
60257
18
60258
18
60259
18
60260
18
™
Multi 9™ System Catalog
Index
98
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
60261
18
60262
18
60263
18
60264
18
60265
18
60266
18
60267
18
60268
18
60269
18
60270
18
60271
18
60272
18
60273
18
60274
18
60275
18
60276
18
60277
18
60278
18
60279
18
60280
18
60281
18
60282
18
60283
18
60284
18
60285
18
60286
18
60287
18
60288
18
60289
18
60290
18
60291
18
60292
18
60293
18
60294
18
60295
18
60296
18
60297
18
60298
18
60299
18
60488
45
60949
34
60950
34
60951
34
60952
34
60954
34
60955
34
60969
34
60971
34
60972
34
60989
34
60990
34
60991
34
60992
34
60993
34
60995
34
60996
34
60999
34
83992
65
,
77
83993
65
,
77
83994
65
,
77
83995
65
,
77
83996
65
,
77
83997
65
,
77
A
AB1GA
51
AB1GB
51
AB1GC
51
AB1GD
51
AB1GE
51
AB1GF
51
AB1GG
51
AB1GH
51
AB1GI
51
AB1GJ
51
AB1GK
51
AB1GL
51
AB1GM
51
AB1GN
51
AB1GO
51
AB1GP
51
AB1GQ
51
AB1GR
51
AB1GS
51
AB1GT
51
AB1GU
51
AB1GV
51
AB1GW
51
AB1GX
51
AB1GY
51
AB1GZ
51
AB1R0
51
AB1R1
51
AB1R11
51
AB1R12
51
AB1R13
51
AB1R2
51
AB1R3
51
AB1R4
51
AB1R5
51
AB1R6
51
AB1R7
51
AB1R8
51
AB1R9
51
AB1RV
51
M
M9PF4
57
MG10285
45
MG10286
45
MG10287
45
MG12279
23
MG14885
49
MG14892
48
MG17402
23
MG17403
23
MG17404
23
MG17405
23
MG17406
23
MG17407
23
MG17408
23
MG17409
23
MG17411
23
MG17412
23
MG17413
23
MG17414
23
MG17415
23
MG17416
23
MG17417
23
MG17418
23
MG17419
23
MG17421
23
MG17422
23
MG17423
23
MG17424
23
MG17425
23
MG17426
23
MG17427
23
MG17428
23
MG17429
23
MG17432
23
MG17433
23
MG17434
23
MG17435
23
MG17436
23
MG17437
23
MG17438
23
MG17439
23
MG17442
23
MG17443
23
MG17444
23
MG17445
23
MG17446
23
MG17447
23
MG17448
23
MG17449
23
MG17452
23
MG17453
23
MG17454
23
MG17455
23
MG17456
23
MG17457
23
MG17458
23
MG17459
23
MG17461
23
MG17462
23
MG17463
23
MG17464
23
MG17466
23
MG17467
23
MG17468
23
MG17469
23
MG17471
23
MG17472
23
MG17473
23
MG17474
23
MG24110
23
MG24111
23
MG24112
23
MG24113
23
MG24114
23
MG24115
23
MG24116
23
MG24117
23
MG24118
23
MG24119
23
MG24121
23
MG24122
23
MG24123
23
MG24124
23
MG24125
23
MG24126
23
MG24127
23
MG24128
23
MG24129
23
MG24130
23
MG24131
23
MG24132
23
MG24133
23
MG24134
23
MG24136
23
MG24137
23
MG24138
23
MG24139
23
MG24140
23
MG24141
23
MG24142
23
MG24143
23
MG24144
23
MG24145
23
MG24146
23
MG24147
23
MG24148
23
MG24149
23
MG24150
23
MG24151
23
MG24152
23
MG24153
23
MG24154
23
MG24155
23
MG24156
23
MG24157
23
MG24158
23
MG24159
23
MG24160
23
MG24161
23
MG24162
23
MG24163
23
MG24164
23
MG24165
23
MG24166
23
MG24167
23
MG24168
23
MG24169
23
MG24425
23
MG24426
23
MG24427
23
MG24428
23
MG24430
23
MG24431
23
MG24432
23
MG24433
23
MG24434
23
MG24435
23
MG24436
23
MG24437
23
MG24438
23
MG24439
23
MG24440
23
MG24442
23
MG24443
23
MG24444
23
MG24445
23
MG24447
23
MG24448
23
MG24449
23
MG24450
23
MG24451
23
MG24452
23
MG24453
23
MG24454
23
MG24455
23
MG24456
23
MG24457
23
MG24459
23
MG24460
23
MG24461
23
MG24462
23
MG24464
23
MG24465
23
MG24466
23
MG24467
23
MG24468
23
MG24469
23
MG24470
23
MG24471
23
MG24472
23
MG24473
23
MG24474
23
MG24476
23
MG24477
23
MG24478
23
MG24481
23
MG24482
23
MG24483
23
MG24484
23
MG24485
23
MG24486
23
MG24487
23
MG24488
23
MG24489
23
MG24490
23
MG24491
23
MG24500
23
MG24501
23
MG24502
23
MG24503
23
MG24504
23
MG24505
23
MG24506
23
MG24507
23
MG24508
23
MG24509
23
MG24510
23
MG24511
23
MG24512
23
MG24513
23
MG24514
23
MG24516
23
MG24517
23
MG24518
23
MG24519
23
MG24520
23
MG24521
23
MG24522
23
MG24523
23
MG24524
23
MG24525
23
MG24526
23
MG24527
23
™
Multi 9™ System Catalog
Index
99
11/2014
© 2008–2014 Schneider Electric
All Rights Reserved
MG24528
23
MG24529
23
MG24530
23
MG24532
23
MG24533
23
MG24534
23
MG24535
23
MG24536
23
MG24537
23
MG24538
23
MG24539
23
MG24540
23
MG24541
23
MG24542
23
MG24543
23
MG24544
23
MG24545
23
MG24546
23
MG24548
23
MG24549
23
MG24550
23
MG24551
23
MG24552
23
MG24553
23
MG24554
23
MG24555
23
MG24556
23
MG24557
23
MG24558
23
MG24559
23
MG24560
23
MG24561
23
MG24562
23
MG26925
42
MG26928
42
MG26970
52
MG26975
50
MG26976
50
MG26978
50
MG26983
54
MG26984
54
MG26985
54
MG26986
54
MG26987
54
MG26988
54
MG26989
54
MG26990
54
MG26996
54
MG27001
50
MG27046
52
MG27047
52
MG27048
52
MG27062
49
MG27124
55
MG27145
52
MGN61300
20
MGN61301
20
MGN61302
20
MGN61303
20
MGN61304
20
MGN61305
20
MGN61306
20
MGN61307
20
MGN61308
20
MGN61309
20
MGN61310
20
MGN61311
20
MGN61312
20
MGN61313
20
MGN61314
20
MGN61315
20
MGN61316
20
MGN61317
20
MGN61318
20
MGN61319
20
MGN61320
20
MGN61321
20
MGN61323
20
MGN61324
20
MGN61325
20
MGN61326
20
MGN61327
20
MGN61328
20
MGN61329
20
MGN61330
20
MGN61331
20
MGN61332
20
MGN61333
20
MGN61334
20
MGN61335
20
MGN61336
20
MGN61337
20
MGN61338
20
MGN61339
20
MGN61340
20
MGN613400
20
MGN613401
20
MGN613402
20
MGN613403
20
MGN613404
20
MGN613405
20
MGN613406
20
MGN613407
20
MGN613408
20
MGN613409
20
MGN61341
20
MGN613410
20
MGN613411
20
MGN613412
20
MGN613413
20
MGN613414
20
MGN613415
20
MGN613416
20
MGN613417
20
MGN613418
20
MGN613419
20
MGN61342
20
MGN613420
20
MGN613422
20
MGN613423
20
MGN613424
20
MGN613425
20
MGN613426
20
MGN613427
20
MGN613428
20
MGN613429
20
MGN61343
20
MGN613430
20
MGN613431
20
MGN61344
20
MGN61345
20
MGN61346
20
MGN61347
20
MGN61348
20
MGN61349
20
MGN61350
20
MGN61351
20
MGN61352
20
MGN61353
20
MGN61354
20
MGN61356
20
MGN61357
20
MGN61358
20
MGN61359
20
MGN61360
20
MGN61361
20
MGN61362
20
MGN61363
20
MGN61364
20
MGN61365
20
MGN61366
20
MGN61367
20
MGN61368
20
MGN61369
20
MGN61370
20
MGN61371
20
MGN61372
20
MGN61373
20
MGN61374
20
MGN61375
20
MGN61376
20
MGN61377
20
MGN61378
20
MGN61379
20
MGN61380
20
MGN61381
20
MGN61382
20
MGN61383
20
MGN61384
20
MGN61385
20
MGN61386
20
MGN61387
20
MGN61389
20
MGN61390
20
MGN61391
20
MGN61392
20
MGN61393
20
MGN61394
20
MGN61395
20
MGN61396
20
MGN61397
20
MGN61398
20
MGN61399
20
U
US11220018
55
US12420018
55
US13620018
55
US14820018
55
US16020018
55
US21215018
55
US22420018
55
US23620018
55
US24820018
55
US26020018
55
US31220018
55
US32420018
55
US33620018
55
US34820018
55
US36020018
55
Schneider Electric USA, Inc.
800 Federal Street
Andover, MA 01810 USA
888-778-2733
www.schneider-electric.us
Schneider Electric Canada, Inc.
5985 McLaughlin Road
Mississauga, ON L5R 1B8 Canada
800-565-6699
www.schneider-electric.ca
Schneider Electric, Square D, and Multi 9 are trademarks owned by Schneider
Electric Industries SAS or its affiliated companies. All other trademarks are the
property of their respective ow ners.
Schneider Electric, Square D et Multi 9 sont des marques commerciales de
Schneider Electric Industries SAS ou de ses compagnies affiliées. Toutes les
autres marques commerciales utilisées dans ce document sont la propriété de
leurs propriétaires respectifs.
0860CT0201 R11/14 Replaces / Remplace Replaces 0860CT0201 R07/14
© 2008–2014 Schneider Electric All Rights Reserved / Tous droits réservés
11/2014