Catalog Number
Notes Type
FEATURES & SPECIFICATIONS
CONSTRUCTION — Weldable-grade, hot-rolled, commercial-quality carbon steel
tubing with a minimum yield of 55,000 psi (11-gauge), or 50,000 psi (7-gauge). Uniform
wall thickness of .125" or .188". Shaft is one-piece with a full-length longitudinal
high-frequency electric resistance weld. Uniformly square in cross-section with
flat sides, small corner radii and excellent torsional qualities. Available shaft widths
are 4, 5 and 6 inches.
Poles have mastic coating on embedded depth +6" above grade level. Base shroud
is finished to match pole. Two drilled conduit access holes, 180 degrees apart, are
located 18" below grade.
A handhole having nominal dimensions of 3" x 5" for all shafts. Included is a cover
with attachment screws.
Top cap provided with all drill-mount poles.
Fasteners are high-strength galvanized, zinc-plated or stainless steel.
Finish: Must specify finish.
Grounding: Provision located immediately inside handhole rim. Grounding hard-
ware is not included (provided by others).
NOTE: Specifications subject to change without notice.
Direct Burial
SSSDB
SQUARE STRAIGHT STEEL
Outdoor Sheet #: Pole-SSSDB
Lead times will vary depending on options selected. Consult with your sales representative.
Example: SSSDB 20 5C DM19 DDB
ORDERING INFORMATION
NOTES:
1 When ordering tenon mounting and drill mounting for the same pole,
follow this example: DM28/T20. The combination includes a required
extra handhole.
2 The drilling template to be used for a particular luminaire depends on
the luminaire that is used. Refer to the Technical Data Section of the
Outdoor Binder for Drilling Templates.
3 Insert "1" or "2" to designate fixture size; e.g. DM19AST2.
4 Specify location and orientation when ordering option.
For 1st "x": Specify the height in feet above base of pole.
Example: 5ft = 5 and 20ft = 20
For 2nd "x": Specify orientation from handhole (A,B,C,D)
Refer to the Handhole Orientation diagram above.
5 Horizontal arm is 18" x 2-3/8" O.D. tenon standard.
6 Combination of tenon-top and drill mount includes extra handhole.
7 Must add original order number.
8 Use when mill certifications are required.
9 Additional colors available; see www.lithonia.com/archcolors or Archi-
tectural Colors brochure (Form No. 794.3). Powder finish standard.
SSSDB
Series
SSSDB
Nominal fixture
mounting height
10 – 30 feet
(see back page.)
Nominal shaft base size/
wall thickness
(See back page.)
Mounting1
Tenon mounting
PT Open top
T20 2-3/8" O.D. (2" NPS)
T25 2-7/8" O.D. (2-1/2"
NPS)
T30 3-1/2" O.D. (3" NPS)
T35 4" O.D. (3-1/2" NPS)
Drill mounting2
DM19 1 at 90°
DM28 2 at 180°
DM28PL 2 at 180° with one
side plugged
DM29 2 at 90°
DM39 3 at 90°
DM49 4 at 90°
CSX/DSX/ALX/AERIS™/OMERO™ Drill
mounting2
DM19AS 1 at 90°
DM28AS 2 at 180°
DM29AS 2 at 90°
DM39AS 3 at 90°
DM49AS 4 at 90°
AERIS™ Suspend drill mounting2,3
DM19AST_ 1 at 90°
DM28AST_ 2 at 180°
DM29AST_ 2 at 90°
DM39AST_ 3 at 90°
DM49AST_ 4 at 90°
OMERO™ Suspend drill mounting2,3
DM19MRT_ 1 at 90°
DM28MRT_ 2 at 180°
DM29MRT_ 2 at 90°
DM39MRT_ 3 at 90°
DM49MRT_ 4 at 90°
Options
Shipped installed
VD Vibration damper
TP Tamper proof
H1-18Sxx Horizontal arm bracket
(1 fixture)4,5
FDLxx Festoon outlet less
electrical4
CPL12 xx 1/2" coupling4
CPL34 xx 3/4" coupling4
CPL1 xx 1" coupling4
NPL12 xx 1/2" threaded nipple4
NPL34 xx 3/4" threaded nipple4
NPL1 xx 1" threaded nipple4
EHHxx Extra handhole4,6
MAEX Match existing7
USPOM United States point of
manufacture8
Finish9
Standard colors
DDB Dark bronze
DWH White
DBL Black
DMB Medium bronze
DNA Natural aluminum
GALV Galvanized finish
Classic colors
DSS Sandstone
DGC Charcoal gray
DTG Tennis green
DBR Bright red
DSB Steel blue
Architectural colors
(powder finish)9
HANDHOLE ORIENTATION
Handhole
A
B
C
D
Lithonia Lighting
Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 770-922-9000 Fax: 770-918-1209
www.lithonia.com
SSSDB Square Straight Steel Direct Burial Poles
IMPORTANT:
These specifications are intended for general purposes only.
Lithonia reserves the right to change material or design, without
prior notice, in a continuing effort to upgrade its products.
IMPORTANT INSTALLATION NOTES:
• Do not erect poles without having fixtures installed.
If poles are stored outside, all protective wrapping must be
removed immediately upon delivery to prevent finish damage.
Lithonia Lighting is not responsible for the foundation design.
TECHNICAL INFORMATION
EPA (ft2) with 1.3 gust
Catalog
number
Nominal
mounting
height above
grade (ft.)
Pole shaft
size (in. x ft.)
Embedment
depth (ft.)
Wall
thickness
(in.) Gauge 80 mph
Max.
fixture
weight
(lbs.) 90 mph
Max.
fixture
weight
(lbs.)
100
mph
Max.
fixture
weight
(lbs.)
Approx.
ship
weight
(lbs.)
SSSDB 10 4C 10 4 x 13 3 0.125 11 30.6 765 23.8 595 18.9 473 95
SSSDB 12 4C 12 4 x 16 4 0.125 11 24.4 610 18.8 470 14.8 370 110
SSSDB 14 4C 14 4 x 18 4 0.125 11 19.9 498 15.1 378 11.7 293 120
SSSDB 16 4C 16 4 x 20 4 0.125 11 15.9 398 11.8 295 8.9 223 130
SSSDB 18 4C 18 4 x 22 4 0.125 11 12.6 315 9.2 230 6.7 168 140
SSSDB 20 4C 20 4 x 24 4 0.125 11 9.6 240 6.7 167 4.5 150 150
SSSDB 20 4G 20 4 x 24 4 0.188 7 14.0 350 11.0 275 8.0 200 210
SSSDB 20 5C 20 5 x 24 4 0.125 11 17.7 443 12.7 343 9.4 235 195
SSSDB 20 5G 20 5 x 24 4 0.188 7 28.1 703 21.4 535 16.2 405 275
SSSDB 25 4G 25 4 x 30 5 0.188 7 10.8 270 7.7 188 5.4 135 255
SSSDB 25 5C 25 5 x 30 5 0.125 11 9.8 245 6.3 157 3.7 150 235
SSSDB 25 5G 25 5 x 30 5 0.188 7 18.5 463 13.3 333 9.5 238 370
SSSDB 30 5G 30 5 x 35 5 0.188 7 10.7 267 6.7 167 3.9 100 390
SSSDB 30 6G 30 6 x 35 5 0.188 7 19.0 475 13.2 330 9.0 225 530
BASE DETAIL
© 2011 Acuity Brands Lighting, Inc. All rights reserved. Rev. 11/22/11.
Sheet #: Pole-SSSDB
WIRE INLET
HOLE 18”
BELOW
GRADE
“B”
EMBEDDED
DEPTH
1-1/2” DIA.
GROMMETTED
WIRE INLET
HOLE
SQUARE
EMBEDDED
(DIRECT BURIAL)
HAND
HOLE 18”
ABOVE
GRADE
MASTIC COATING
TO 6” ABOVE
GROUNDLINE