118604 Catalog

596050-Attachment 596050-Attachment 596050-Attachment 768386 Batch5 unilog cesco-content

118520-Attachment 118520-Attachment 118520-Attachment 014364 Batch10 unilog cesco-content

118604-Catalog 118604-Catalog 118604-Catalog 043168 Batch5 unilog cesco-content

118604-Catalog 118604-Catalog 118604-Catalog 768386 Batch5 unilog cesco-content

596057-Attachment 596057-Attachment 596057-Attachment 768386 Batch7 unilog cesco-content

2014-07-05

: Pdf 118604-Catalog 118604-Catalog 014364 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 193

Download118604-Catalog
Open PDF In BrowserView PDF
Ballast
Navigator
Universal Lighting Technologies is a member of the Panasonic Group

Table of Contents
Fluorescent Electronic Ballasts	
Section 1-	Page
	
Product Overview............................................................................................................................................1-2
	
Application Operation Information.................................................................................................................1-4
	
Typical Specifications......................................................................................................................................1-7
	F17T8.............................................................................................................................................................1-13
	F25T8.............................................................................................................................................................1-15
	
F32T8 (32, 30, 25 & 28 Watt Four Foot Lamps)........................................................................................1-19
	
F28T8 (32, 30, 25 & 28 Watt Four Foot Lamps)........................................................................................1-29
	F40T8.............................................................................................................................................................1-32
	
F96T8 Slimline..............................................................................................................................................1-34
	
F96T8HO High Output.................................................................................................................................1-35
	T5....................................................................................................................................................................1-36
	T5HO..............................................................................................................................................................1-38
	T12 .................................................................................................................................................................1-42
	
T12 Slimline...................................................................................................................................................1-44
	
T12HO High Output......................................................................................................................................1-46
	T2....................................................................................................................................................................1-47
Energy Management Systems 	
Section 2-	Page
--DCL With DEMANDflex
	
Product Overview............................................................................................................................................2-2
	
DEMANDflex T8............................................................................................................................................2-3
	
DEMANDflex T5, T5HO & TT5...................................................................................................................2-6
	
DEMANDflex T8 Wiring Diagrams..............................................................................................................2-7
	
DCL Controls...................................................................................................................................................2-8

FOR MORE INFORMATION CALL

i

1-800-BALLAST
(225-5278)

Table of Contents

Controllable Lighting	
Section 2-	Page
--Fluorescent Energy Management/Dimming Ballasts and Controls
	
Product Overview..........................................................................................................................................2-10
	
-- BallaSTAR Light Level Switching.........................................................................................................2-10
	
-- SuperDim Analog Dimming...................................................................................................................2-11
	
-- DaliPRO Digital Dimming......................................................................................................................2-12
	
-- VariPRO Parallel-Lamp Dimming.........................................................................................................2-13
	
-- LevelPRO Parallel-Lamp Dimming.......................................................................................................2-13
	
Application Operation Information...............................................................................................................2-14
	
Controls for Analog Dimming Ballasts........................................................................................................2-15
	DaliPRO.........................................................................................................................................................2-16
	
DaliPRO Premium.........................................................................................................................................2-17
	SuperDim.......................................................................................................................................................2-18
	
BallaSTAR 0-10 Volt....................................................................................................................................2-19
	
BallaSTAR Light Level Switching...............................................................................................................2-20
	
Dimensions & Wiring Diagrams..................................................................................................................2-22
	VariPRO.........................................................................................................................................................2-23
	LevelPRO.......................................................................................................................................................2-26

Table of Contents
Compact Fluorescent Ballasts	
Section 3-	Page
	
Product Overview............................................................................................................................................3-2
	
Understanding Compact Fluorescent Technology.........................................................................................3-3
	Configurations..................................................................................................................................................3-4
	
Lamp Matrix....................................................................................................................................................3-5
	
Typical Specifications......................................................................................................................................3-6
	Nomenclature...................................................................................................................................................3-7
	
13-26 Watt Twin, Quad and Triple.................................................................................................................3-9
	
32 to 70 Watt Triple and Multiple................................................................................................................3-10
	2D...................................................................................................................................................................3-12
	
T5 Circular.....................................................................................................................................................3-15
	
Long Twin T5................................................................................................................................................3-16
High Intensity Discharge (HID) Ballasts 	
Section 4-	Page
	
Product Overview............................................................................................................................................4-2
	
Oil Filled Capacitors........................................................................................................................................4-4
	
Dry Capacitors.................................................................................................................................................4-5
	
Bracket Reference Chart..................................................................................................................................4-6
	
Application and Operation Information..........................................................................................................4-7
	Nomenclature.................................................................................................................................................4-10
	
Typical Specifications....................................................................................................................................4-11
	
Distributor Replacement Kits........................................................................................................................4-12
	
Core and Coil
		
Metal Halide ........................................................................................................................................4-16
		
Pulse Start Metal Halide......................................................................................................................4-20
		
High Pressure Sodium..........................................................................................................................4-27
	
50 Hz Core and Coil Ballasts........................................................................................................................4-33
	
F-Can Ballast..................................................................................................................................................4-37
	Ignitors............................................................................................................................................................4-38
	
Reference Drawings.............................................................................................................................4-40

Table of Contents

Electronic High Intensity Discharge (eHID) Ballasts 	
Section 5-	Page
	
Product Overview............................................................................................................................................5-2
	
Product Family Chart.......................................................................................................................................5-3
	
Wiring Diagrams..............................................................................................................................................5-4
	Dimensions.......................................................................................................................................................5-5
	
Application and Operation Information..........................................................................................................5-8
Lampholders 	
Section 6-	Page
	
Application and Operation Information..........................................................................................................6-2
	
T8 & T12..........................................................................................................................................................6-5
	T5......................................................................................................................................................................6-9
	HID.................................................................................................................................................................6-11
	Halogen..........................................................................................................................................................6-15
	CFL.................................................................................................................................................................6-19
Sign Ballasts 	
Section 7-	Page
	
Application and Operation Information..........................................................................................................7-2
	
Sign Ballast Footage Chart & Lead Lengths..................................................................................................7-3
	
Electronic Sign Ballasts...................................................................................................................................7-4

FOR MORE INFORMATION CALL

ii

1-800-BALLAST
(225-5278)

Table of Contents
Glossary 	
Section 8-	Page
	
..........................................................................................................................................................................8-1
Index 	
Section 9-	Page
	
..........................................................................................................................................................................9-1
Warranty 	
Section 10-	Page
	
........................................................................................................................................................................10-1

Table of Contents

FOR MORE INFORMATION CALL

iii

1-800-BALLAST
(225-5278)

Electronic
Fluorescent Ballasts
A Complete Range of Solutions
— From The Name You Trust
For more than 30 years, the lighting industry has relied on
our TRIAD® brand for the most specified, most installed,
most reliable electronic ballasts in the business.
The TRIAD® line offers advantages like installer-friendly
universal input voltage, which ensures that you have the
right voltage ballast every time, and maximum energy
savings for long cycle operations.
And our ULTim8® and AccuStart™ ballasts feature high
efficiency designs and programmed start technology that
dramatically enhances lamp life.

Universal Lighting Technologies is a member of the Panasonic Group

Fluorescent-Electronic
Fluorescent-Electronic

Universal is the leader in energy saving electronic ballasts.

Product Overview
Setting The Pace In T8 Technology

Universal Lighting keeps pushing the frontier of T8 technology with innovative products that deliver
dramatic energy savings, greater fixture design flexibility, longer lamp life and installation ease. You
can count on Universal for some of the industry’s highest efficiency and most hassle-free T8 ballasts.
Universal offers high efficiency T8 ballasts for Instant Start and Programmed Start applications. These
ballasts deliver up to 6% additional energy savings over standard electronic ballasts, even more when
used with the new F32T8/ES (25 Watt), F32T8/ES (30 Watt) or F28T8 (28 Watt) lamps. Our T8 ballasts
are CEE and NEMA Premium compliant.
TRIAD® and ULTim8 Instant Start Applications
Instant Start technology for continuous operation and installer friendly Universal input voltage.
Maximizes energy savings for long cycle operations.
- Some of the most efficient ballasts in the industry for maximum energy savings.
- Available in high efficiency HE normal (.88), EL low (.77), and HEH high (1.18) ballast factor versions.
- Independent lamp operation simplifies troubleshooting. Lamps stay lit if one lamp fails preventing
fixtures from going dark and replacing lamps unnecessarily.
- Lamp will auto-restrike as a standard feature allowing replacement of lamps without recycling power.
- Anti-striation control for better light quality when using energy saving lamps.
- Universal input voltage, installer friendly.
- Because these ballasts are CEE and NEMA Premium compliant they may qualify for utility incentives.
- Backed by 5 year warranty when operated at 75° C max case temperature.

Fluorescent-Electronic

ULTim8® Programmed Start Applications
Features true parallel lamp operation and fast start time (<700ms) so that if one lamp fails, other lamps stay lit.
“Soft start” technology maintains lamp life, making these the perfect choice for high-cycling applications like
occupancy sensors. Designed for use with 30, 28 and 25 Watt energy saving lamps for even more energy savings.
- Same benefits as Instant Start plus ...
- Available in high efficiency HE normal (.88) and EL low (.71), and HEH (1.18) ballast factor versions.
- Programmed Start ballasts are designed to quickly pre-heat lamp cathodes up to their optimum starting
temperature and ignite the lamps quickly.
- Filament cut out on HE and HEH models for instant start level efficiency.
- The quick ignition results in long lamp life without the typical long delay during turn-on.
- Same 5 year warranty as instant start or 3-year warranty for HEH modules when operated at 90° C case temperature.
High Lumen and High Bay Applications
ULTim8® High Lumen ballasts are the high efficiency high ballast factor choice for high lumen T8 applications.
ULTim8® HB ballasts are designed to provide excellent performance in the high ambient temperature
applications where high bay fluorescent fixtures are installed.
EL Ballasts: Used often when retrofitting existing T12 fixtures with T8 lamps to tune down lamp output.
Application areas include stairwells, hallways, bathrooms and other areas that are lit partially during the day.
They are good for using in low light level areas. Change light levels with ballast factor.
HE Ballasts: Used often in new construction, the high efficiency version of our standard HP product. Used for
frequently switched applications including occupancy sensors and daylight harvesting. They are a good solution
for education, commercial offices and retail.
HEH Ballasts: Used to overdrive lamps. Use these for areas with high light output. They are a great solution for
high bay fixtures including applications for warehouses and manufacturing.

PAGE 1-2

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Product Overview
T5 & T5HO Ballasts For Architectural and High Bay Applications

Whether it’s for new construction or a retrofit project, Universal’s T5 and T5HO ballasts, with their smaller size
and high lumen output, have become the dominant player in architectural and high bay applications.
Programmed Start ballasts feature a “soft start” technology that maximizes lamp life, making them the perfect
choice for high cycling applications including those involving occupancy sensors and wall switches.
High Efficiency (AccuStart5®, ULTim5®):
Our high efficiency T5 and T5HO ballasts are ideal for bathrooms, hallways, stairwells, gymnasiums,
classrooms, libraries, corridors, offices, recessed volumetric strips, wraps, wall washing, displays, direct/indirect
lighting, surface mount, cove, under cabinet or task lighting. Common applications include: commercial, retail,
hospitality, restaurants, law offices, medical, institutional, airports, and schools.
The AccuStart5® and ULTim5® lines of linear fluorescent T5 and T5HO ballasts offer broad appeal to the most common applications. Universal input voltage (108-305 volts). T5 ballasts support (1) or (2) 2’ F14T5, 3’ F21T5, 4’ F28T5,
and 5’ F35T5 full wattage and energy saving lamps. T5HO ballasts support (1) or (2) 2’ F24T5HO 3’ F39T5HO and (1) (2)
(3) or (4) 4’ F54T5HO full wattage and energy saving lamps.
High Bay (AccuStart5HB®):
T5HO High Bay ballasts are ideal for new construction and fixture retrofits in gymnasiums, high bay retail stores
and warehouses, manufacturing sites, industrial facilities and similar applications. These High Output ballasts
are well suited for applications where space is at a premium, including slim pendant mounted fixtures, cove and
task lighting. AccuStart5HB ballasts offer a replacement opportunity for traditional HID high bay applications.
Light up the aisles for the forklift operator when lighting is needed. Keep spaces lit when and where needed.
Universal offers the AccuStart5HB® line of linear fluorescent T5HO ballasts for High Bay applications. Ideal
for extreme temperature (90° C Case Warranty). Universal input voltage (108-305 volts) and high range voltage
(347-480 volts). These ballasts support (2) and (4) 117, 119, 120, 182, 184, 229 and 235 watt T5HO ballasts.
Canadian Voltage:
Universal offers Canadian voltage in 347V and high range voltage. These ballasts come in standard efficiency,
high efficiency and High Bay for T5 and T5HO applications.

Fluorescent-Electronic

Family of Universal HP Ballasts.

Flexible Fixture design options for T5 and T5HO lamps.

PAGE 1-3

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Application And Operating Information
SAFETY

NEC & UL Requirements
Ballast installation presents the possibility of exposure to potentially hazardous voltages and should be performed only by qualified personnel. All installation, inspection and maintenance should be performed only with power to the fixture turned off. Additionally, all fixtures and
ballasts must be installed and operated in compliance with the National Electrical Code, Underwriters Laboratories Inc. (UL) requirements,
and all local applicable codes and regulations.
Polarity
Polarity refers to the proper connection of ballast lead wires to line wires. To aid you in a correct installation, Universal ballast leads are
color-coded for easy identification. The WHITE ballast lead is to be connected to the neutral (grounded) and the BLACK (or black with
white tracer) lead always to the phase (“hot”) line wire. Systems where neither of the line wires are at ground potential require specially
designed ballasts. A change in polarity may result in the voltage from the lead to the ground exceeding UL-specified limits. In some types of
ballasts, a change in polarity may decrease voltage from the lead to the ground, thereby impeding the starting dependability of the ballast.
Grounding
Ballast cases and fixtures must always be grounded. The ballast case may be grounded to the fixture or otherwise grounded. It could be
hazardous to make contact with an ungrounded fixture or ballast when in operation. Neglecting to properly ground the ballast and fixture
combination may also result in failure of certain lamps to start or for unacceptable levels of electromagnetic noise to be conducted onto the
power lines.
Operating Line Voltage Limits
To receive the full benefits of rated lamp output and to prolong ballast life, it is essential that voltage supplied to an installation be maintained within limits prescribed for each circuit. These limits are listed below:

	
Nominal Voltage	
	120	
	220	
	277	
	347	
	 120-277 (UNV)	
	 347-480 (HRV)	

VOLTAGE RANGE
Minimum	

Maximum

108	
198	
249	
312	
108	
312	

132
242
305
382
305
528

Fluorescent-Electronic

Subjecting a ballast to excessive voltage for an extended period results in the deterioration of the insulation. This insulation breakdown will
cause early ballast failure. Low voltage has no damaging effect on the ballast. However, lamps may not start reliably, and early lamp failure
could result.
Internal Ballast Protection
Class P Classification - Since January 1, 1984, the National Electrical Code requires that “where Fluorescent fixtures are installed indoors,
the ballast shall have thermal protection integral within the ballast except for simple reactance ballasts.” This ruling applies to replacement
ballasts as well as to those contained within new fixtures.
In compliance with the National Electrical Code, UL has established a Class P ballast classification for fluorescent light fixtures.
A Class P ballast must employ internal thermal protection limiting its operating temperature.
Universal UL-approved Class P ballasts comply with the National Electrical Code requirement and are equipped with an automatic resetting
thermal protector, built-in and adjacent to the transformer coils. The resetting thermal protector functions as a thermostat which will open
and temporarily deactivate the ballast when it exceeds the permissible temperature. It will reset when the ballast cools to a safe operating
temperature. The ballast will continue to cycle until the cause of overheating is eliminated. If the ballast is defective, it must be replaced. If
the cause is external, a Class P ballast will resume normal operation after abnormal conditions are eliminated.

PAGE 1-4

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Application And Operating Information
SAFETY

Dimming Ballasts - Ballastar® Dimming Ballasts are controlled by using 10-0vDC. Care should be taken to insure that the line voltage
(AC) wires are not connected to the low voltage DC wires. Ballastar® Electronic Dimming Ballasts have protection (safety) circuitry,
that will sense the error so as not to harm the installer or the ballast. Dimming ballasts manufactured after May 1999 have the protection circuit. Dimming ballasts manufactured before this date do not have low voltage circuit protection.
Fusing - Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts. For
a comprehensive list of appropriate fuses, contact our Technical Engineering Services (TES) Department at 1-800-BALLAST
or check out our TES home page at www.unvlt.com.
Grounding - ANSI C82.1 recommends all fixtures and ballasts be grounded. Universal requires all electronic ballasts be grounded.
Thermal Protection - All Universal electronic ballasts meet UL 935 Standard for thermal protection. These ballasts are designated
Class P. A Class P ballast will disconnect the ballast from input power in the event of internal over-temperature.

PERFORMANCE

Lamp Connections
Fluorescent ballasts are designed to generate voltages in excess of 300 volts. It is imperative that proper connection to quality
Lampholders be assured in accordance with wiring diagrams on each page of the catalog and on product labels. Some applications
may not require the use of all of the ballast output leads. If any leads are not to be connected, each should be individually capped
and insulated to at least 600 volts.
Application Versatility
Many Universal models are designed to allow for applications with different types or quantities of lamps. Lamp applications not listed on
label cannot be warranted.
Audible Noise (Sound)
Electrical equipment, including most fluorescent lamp ballasts, produces some noise. Care must be taken to select a ballast with the proper
sound rating for a particular lighting installation. Secure mounting can reduce the potential for audible noise.
EMI/RFI
Electronic ballasts operate at high frequency and, therefore, may produce radio frequency interference (RFI) or electromagnetic
interference (EMI). Some sensitive electrical equipment such as televisions, radios, or some medical equipment can be adversely
affected by this RFI or EMI interference. Currently the electronic frequencies from 450 kilohertz (kHz) to 300 megahertz (MHz) are
regulated by the FCC. For electronic ballasts, the limits and regulations are listed in the Code of Federal Regulations, Title 47, Part 18,
Subpart C titled RF Lighting Devices. ULT provides ballasts compliant with non-consumer limits for commercial applications,
as well as several models in compliance with consumer limits for residential use. 
See the Data Sheets for the electronic ballast of interest to determine which FCC requirement, consumer or non-consumer
the particular product meets.
Remote Mounting
Excessive hot or cold temperatures, audible noise requirements, or a desire to operate lamps in more than one fixture with the same ballast
(tandem), may make it desirable to mount the ballast remotely. Care must be taken to allow for ballast heat dissipation and proper grounding.

Lead lengths in excess of those noted cause loading effects that can dramatically impact ballast performance and void the warranty.
See individual data sheets to determine all wiring options.

PAGE 1-5

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

In any application, the wire used to extend leads must be at least as large as the wire supplied on the ballast (18 AWG) with an insulation
rating of 1000 VAC at 90°C.

Application And Operating Information
PERFORMANCE

	
•	 Lamp Starting Dependability
		 Fluorescent lamps are inherently more difficult to start at low temperatures. All ballasts have limitations
		 as to their ability to start lamps at low ambient temperatures. In this catalog, the low starting point for
		 each lamp/ballast combination appears in the column marked “Minimum Starting Temperature.”
		 Universal four lamp instant start ballasts can operate at a minimum starting temperature down to -18°C (0°F)
		 under the following conditions:
			
1.	 Lead lengths to the lamps are those supplied, by Universal, with the ballast or shorter.
			
2.	 The distance from the lamp to the ground plane is no greater than 3/4”.
			
3.	 The line voltage supplied to the ballast is no less than rated nominal.
			
4.	 The ballast or lamps are not remotely mounted.
			
5.	 The lamps have been burned in per lamp manufacturer requirements (typically 100 hours).
		 The lamp manufacturer should be contacted for lamp operating characteristics and requirements below 15°C (50°F).
	
•	 Light Output
		 Optimum light output from fluorescent lamps is achieved when the lamp wall is at 100-110°F.
		 Any substantial excursion (either colder or warmer) will result in a reduction in light output.
	
•	 Ballast Life
		 A fluorescent lamp ballast, like any other electrical device, generates heat during its normal operation.
		 Ballast temperatures should be kept as low as possible. Maximum dissipation of heat through fixture
		 design and proper ballast installation will help. Although excessive temperature may not cause the
		 ballast to fail immediately, it can shorten ballast life. To assure maximum life, the ballast case temperature
		 should not exceed 75˚C, in a maximum ambient (fixture cavity) of 40˚C.
	
			
Causes of ballast overheating:
				
•	 Incorrect line voltage or frequency
				
•	 Incorrect size, type or number of lamps
				
•	 Incorrect wiring
				
•	 Poor heat dissipation due to surrounding insulation
				
•	 Sealed (Vapor Tight) Fixtures - Unusual heat build-up due to lack of ventilation in
					 fixtures may cause thermal (on/off) cycling of certain ballasts. Consult Universal for
					 specific recommendations.

Fluorescent-Electronic

			
RECOMMENDATIONS...
	
				
•	 Selection of a proper ballast to match the requirements of the lamp,
					 fixture, voltage and installation.
				
•	
					
					
					

Mounting of ballast within the fixture with as much surface contact
as possible between the ballast and metal portions of the fixture.
Secure mounting will aid in proper heat dissipation and can minimize
the potential for ballast hum.

				
•	 The use of heat-conducting dissipators (radiators), if necessary,
					 which increase surface contact between the ballast and fixture.
				

•	 If necessary, locate the ballast in a remote, cooler area outside the fixture.

				

•	 Consult Universal for remote mounting recommendations.

	
•	 Starting Method Legend
			
IS = Instant Start
			
PS = Programmed Start
			
RS = Rapid Start
			
PAR-IS = Parallel Instant Start
			
PAR-PS = Parallel Programmed Start
			
PAR-RS = Parallel Rapid Start
			
SER-RS = Series Rapid Start

PAGE 1-6

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Specifications
TYPICAL SPECIFICATIONS
FOR T8 INSTANT START BALLASTS:
– HP (High Performance Normal Ballast Factor)
– EL (High Efficiency Low Ballast Factor)
– HE (High Efficiency Normal Ballast Factor)
– HEH (High Efficiency High Ballast Factor)
• Ballasts shall include 18AWG solid copper leads color coded in compliance with ANSI C82.11-2011.
• Ballasts shall be instant start and provide starting sequence consistent with ANSI standard C82.11-2011.
• Ballasts (1-4 lamps) shall operate as Parallel Circuit, allowing remaining lamp(s) to maintain full light output if one or more lamps fail.
• Ballasts shall operate from 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ± 10% (Voltage & Frequency)
	 with no damage to the ballasts.
• Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 42 kHz to minimize interference with infrared
	 control systems.
• Ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage.
• Ballasts shall have a minimum starting temperature of 0°F (-18°C) for the primary lamp application.
• Ballasts shall have a maximum case temperature test point of 75°C printed on the label for easy fixture testing and trouble shooting.
• Ballasts shall support 18’ maximum lead length remote mounting for the primary lamp.
• Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (Radiated).
• Ballasts shall provide transient immunity as recommended by ANSI C82.11-2011.
• Ballasts shall auto-restrike allowing replacement of lamps without cycling power.
• Ballasts shall incorporate Anti-Striation Circuitry for stable operation of reduced wattage lamps.
• Ballasts shall operate lamps with no visible flicker (<3% flicker index).
• Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage.
• Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor and/or CSA certified for both US and Canadian application.
• Ballasts shall meet NEMA Premium/CEE High Performance for high efficiency operation.
• Ballasts shall be quiet Class A sound rating.
• Ballasts shall have a Ballast Factor for the primary lamp application of greater than .77 for EL, .85 for HE and 1.15 for HEH, per ANSI
	C82.11-2011.
• Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.

• Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and
	 ANSI C82.11-2011.
• The ballasts shall not have any PCB’s.
• The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from
	 date of manufacture.
• Manufacturer shall have been manufacturing electronic ballasts for at least thirty years.
• Ballasts shall be manufactured in an ISO 9001/ISO 9002 certified facility in North America.
•	 Ballasts shall be Universal Lighting Technologies Bx32IUNVHP-N (x=1or 2) or Bx32IUNVHP-A (x= 3or 4) depending upon the quantity of
	 lamps per fixture.

PAGE 1-7

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

• Ballasts shall have a Power Factor greater than .98 for primary lamp.

Specifications
TYPICAL SPECIFICATIONS
FOR T8 PROGRAMMED START BALLASTS:
– EL (High Efficiency Low Ballast Factor)
– HE (High Efficiency Normal Ballast Factor)
– HEH (High Efficiency High Ballast Factor)
•	 Ballasts shall include 18AWG solid copper leads color coded in compliance with ANSI C82.11-2011.
•	 Ballasts shall be Programmed Start with arc current established in less than 700 milliseconds after power is applied.
•	 Ballasts (2-4 lamps) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light output if one or more lamps fail.
•	 Ballasts shall have a minimum Rh/Rc of 4.25 each time the lamps are started.
•	 Ballasts shall have a maximum ionization current (Glow Current) of 10 milliamps during preheating interval.
•	 Ballasts shall operate from a 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ± 10% (Voltage & Frequency) with no
	 damage to the ballasts.
•	 Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 42 kHz to minimize interference with infrared control
	systems.
•	 EL and HE ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage. In addition, HEH ballasts shall operate
	 up to a 194°F (90°C) maximum case temperature.
•	 Ballasts shall have a maximum case temperature test point printed on the label for easy fixture testing and trouble shooting.
•	 Ballasts shall have a minimum starting temperature of -20°F (-29°C) for the primary lamp application when not remote mounted.
•	 Ballasts shall support 20’ maximum lead length remote mounting for the primary lamp.
•	 Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (Radiated).
•	 Ballasts shall provide transient immunity as recommended by ANSI C82.11-2011.
•	 Ballasts shall auto-restrike allowing replacement of lamps without cycling power.
•	 Ballasts shall incorporate Anti-Striation Circuitry for stable operation of reduced wattage lamps.
•	 Ballasts shall operate lamps with no visible flicker (<3% flicker index).
•	 Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage.
•	 Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor and/or CSA certified for both US and Canadian application.
•	 Ballasts shall meet NEMA Premium/CEE High Performance for high efficiency operation.
•	 Ballasts shall be quiet Class A sound rating.
Fluorescent-Electronic

•	 Ballasts shall have a Ballast Factor for the primary lamp application of greater than .71 for EL, .88 for HE, and 1.15 for HEH, per ANSI C82.11-2011.
•	 Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp application.
•	 Ballasts shall have a Power Factor greater than 0.98, for the primary lamp application.
•	 Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer
	 recommendation and ANSI C82.11-2011.
•	 The ballasts shall not have any PCB’s.
•	 The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of
	 manufacture. In addition, HEH models shall carry a three year warranty when operated at 194°F (90°C) maximum case temperature.
•	 Manufacturer shall have been manufacturing electronic ballasts for at least thirty years.
•	 Ballasts shall be manufactured in an ISO 9001/ISO 9002 Certified Facility in North America.
•	 Ballasts shall be RoHS compliant.
•	 Ballasts shall be Universal Lighting Technologies ULTim8 Programmed Start Product B232PUNVEL-B, B332PUNVEL-A, B432PUNVEL-A,
	 B232PUNVHE-B, B332PUNVHE-A, B432PUNVHE-A, B232PUNVHEH-A, B332PUNVHEH-A, or B432PUNVHEH-E.
PAGE 1-8

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Specifications
TYPICAL SPECIFICATIONS
FOR T5 & T5HO BALLASTS:
•	 Ballasts shall include 18AWG solid copper leads color coded in compliance with ANSI C82.11-2011 or shall use wire trap terminals for ease of
	installation.
•	 Ballasts shall be Programmed Start.
•	 Ballasts shall operate from a 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ± 10% (Voltage & Frequency) with no
	 damage to the ballasts.
•	 Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 42 kHz to minimize interference with infrared control
	systems.
•	 Ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage. HB ballasts shall operate up to 194°F (90°C)
	 maximum case temperature.
•	 Ballasts shall have a minimum starting temperature of 0°F (-18°C) for the primary lamp application. T5HO ballasts shall have a minimum starting
	 temperature of -20°F (-29°C) for the primary lamp application when not remote mounted.
•	 Ballasts shall support 20’ lead length remote mounting for the primary lamp.
•	 Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (radiated).
•	 Ballasts shall provide transient immunity recommended by ANSI C82.11-2011.
•	 Ballasts shall incorporate lamp shutdown circuitry for end of lamp life protection.
•	 Ballasts shall auto-restrike to allow for re-lamping without the need to cycle power.
•	 Ballasts shall operate lamps with no visible flicker (<3% flicker index).
•	 Ballasts shall tolerate sustained open and short circuit output conditions without damage.
•	 Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and/or CSA certified for both US and Canadian application.
•	 Ballasts shall be quiet Class A sound rating.
•	 Ballasts shall have a Ballast Factor for the primary lamp application greater than .95 per ANSI C82.11-2011. Exceptions are ballasts that
	 specify BF in part number, such as B228PUNV85-D, B228PUNV90-C and B228PUNV115-D.
•	 Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.
•	 Ballasts shall have a Power Factor greater than .98 for the primary lamp application.
•	 Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer
	 recommendation and ANSI C82.11-2011.
•	 The ballasts shall not have any PCB’s.
•	 The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from
	 date of manufacture. In addition, HB ballasts shall carry a three year warranty at a maximum case temperature of 194°F (90°C).
Fluorescent-Electronic

•	 Manufacturer shall have been manufacturing electronic ballasts for at least thirty years.
•	 Ballasts shall be manufactured in an ISO 9001 / ISO 9002 Certified Facility in North America.
•	 Ballast shall be Universal Lighting Technologies Accustart5.

PAGE 1-9

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Specifications
TYPICAL SPECIFICATIONS
FOR ELECTRONIC COMPACT FLUORESCENT BALLASTS:
•	 Ballasts shall be constructed of metal housing to meet plenum and construction code requirements while providing maximum heat transfer
	 without extra grounding wires for extended ballast life.
•	 Ballasts shall be constructed using dual entry color coded wire trap terminals for wiring accuracy and ease of installation.
•	 Ballasts shall be Programmed Start.
•	 Ballasts shall have a minimum Rh/Rc of 4.25 each time the lamps are started.
•	 Ballasts shall have a maximum ionization current (Glow Current) of 25 milliamps during preheating interval.
•	 Ballasts shall operate from 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ± 10% (Voltage &
	 Frequency) with no damage to the ballasts.
•	 Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 50 kHz to minimize interference with infrared
	 control systems.
•	 Ballasts shall have a minimum starting temperature of 0°F (-18°C) for the primary lamp application.
•	 Ballasts shall tolerate operation in ambient temperatures up to 140°F (55°C) without damage.
•	 Ballasts shall have a maximum case temperature test point of 75°C printed on the label for easy fixture testing and trouble shooting.
•	 Ballasts shall support 12’ lead length remote mounting for the primary lamp.
•	 Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (radiated).
•	 Ballasts shall provide transient immunity as recommended by ANSI C82.11-2011.
•	 Ballasts shall incorporate end of lamp life shutdown circuitry for end of lamp life protection.
•	 Ballasts shall allow for re-lamping without the need to cycle power.
•	 Ballasts shall operate lamps with no visible flicker (<3% flicker index).
•	 Ballasts shall tolerate sustained open and short circuit output conditions without damage.
•	 Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor and/or CSA certified for both US and Canadian application.
•	 Ballasts shall be UL 935 Type CC rated to reduce arcing caused by loose connections or improper lamp-pin to lampholder contact.
•	 Ballasts shall be UL 2043 certified for use in plenums and marked on label as “Suitable for Air Handling Spaces”.
•	 Ballasts shall be quiet Class A sound rating.
•	 Ballasts shall have a Ballast Factor for primary lamp application greater than .95 per ANSI C82.11-2011.

Fluorescent-Electronic

•	 Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.
•	 Ballasts shall have a Power Factor greater than .98 for the primary lamp application.
•	 Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and
	 ANSI C82.11-2011.
•	 The ballasts shall not have any PCB’s.
•	 The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from
	 date of manufacture.
•	 Manufacturer shall have been manufacturing electronic ballasts for at least thirty years.
•	 Ballasts shall be manufactured in an ISO 9001 / ISO 9002 Certified Facility in North America.
•	 Ballasts shall be manufactured by Universal Lighting Technologies.

PAGE 1-10

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Notes

Fluorescent-Electronic

Page 1-­11

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Electronic Ballast Applications
Remote Mounting
LAMP
LAMP

BALLAST
Ballast output leads
are run through
conduit to fixture

LAMP
FIXTURE

Configuration is applicable to 1, 2 and 4-lamp fixtures as well.

Through Wiring

FIXTURE
LAMP

LAMP

LAMP

Ballast output leads are run through the fixture to each
lamp, NOT through conduit. Minimize lead lengths by
mounting ballast at the center of the fixture when possible.
Configuration is applicable to 2 and 3-lamp fixtures as well.

Tandem Wiring
2-Ballast Configuration
LAMP BALLAST A

LAMP BALLAST A

BALLAST A

LAMP BALLAST B

LAMP BALLAST B
Fluorescent-Electronic

BALLAST B
LAMP BALLAST A

FIXTURE 1

Output leads from
Ballast A and B are
run through conduit
to second fixture

LAMP BALLAST A
FIXTURE 2

1-Ballast Configuration
BALLAST
LAMP
FIXTURE 1

LAMP
Output lead wire
runs through conduit
to second fixture

PAGE 1-12

FIXTURE 2

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS
FOR (1) & (2)
F17T8 LAMP

F17T8

• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
• 1-2 Lamp Applications

	* For Residential Use Only
Lamp Manufacturers for applications with Ballast Factor > 1.20
2 Consult Universal for Availability
1 Consult

IS = Instant Start
PS = Programmed Start

RS = Rapid Start
PAR-IS = Parallel Instant Start

STARTING METHOD LEGEND

PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start

PAGE 1-­13

See page 1-18 for Dimensions
and Wiring Diagrams
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start

SER-IS = Series Instant Start

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

	 Lamp	 			
Line	
Input	
Power	 Ballast	
Ballast		
Min. F/C	
		 Starting	 Line	
Catalog	
Current	 Power	 Factor	Factor	 Efficacy	 THD	 Start	 Wiring	
	 Qty.	 Method	
Volts	
Number	
(Amps)	 (Watts)	
(PF)	
(BF)	
Factor (BEF)	 %	
Temp	 Diag.	 Dim.
F11T8 - One Lamp Application
	
	
120	 B132IUNVHE-N	
0.09	
11	
> .99	 0.90	
8.18	
< 10	 0/-18	
3a	
-N
1	IS
			
120	 B232IUNVHP-N	
0.12	
14	
> .99	 0.90	
6.43	
< 10	 0/-18	
3a	
-N
F11T8 - Two Lamp Application
	 	
	120	
	
0.17	
20	
> .99	
	
3.90	
< 10	
2 PAR-IS
B232IUNVHP-N
0.78
0/-18	3	-N
			
277		
0.08	
21	
> .96		
3.71	
< 15
F15T8 - One Lamp Application
			
120	 B132IUNVHE-N	
0.11	
14	
> .99	 0.90	
6.43	
< 10	 0/-18	
3a	
-N
1	IS
	
	
120	 B232IUNVHP-N	
0.14	
16	
> .99	 1.02	
6.38	
< 10	 0/-18	
3a	
-N
F15T8 - Two Lamp Application
	 	
	120	
	0.21	 	
> .99	
	3.51	 	
2 PAR-IS
B232IUNVHP-N
25
0.86
< 10
0/-18	3	-N
			 277		
0.09		> .98		 3.50	
F17T8 - One Lamp Application
	 		
120	 B232I120RES-A*	
0.35	
21	
> .50	 1.08	
5.14	
< 150	 0/-18	
3a	
-A	
			
120	 B232I120RES-G*	
0.34	
22	
> .50	 1.08	
4.91	
< 150	 0/-18	
3a	
-G
	 	
	
347	 B132I347HP	
0.05	
18	
> .95	 0.92	
5.11	
< 15	 0/-18	
1	
ST
			
120	
0.17	
	
> .98	
	
	
B232IUNV-C	
20
1.04	5.20
< 10	 0/-18	
21a	
-C
			
277		
0.08	
	
> .95	
	
	
	
		
			
120	
0.12	
	
> .98	
1	IS
B132IUNVEL-A2	
14
0.78	
5.57	
< 15	 0/-18	
1	
-A
	
	
277		
0.06		
> .90	
			
120	
0.14	
	
> .98	
B132IUNVHE-N	
16
0.90	
5.63	
< 10	 0/-18	
1	
-N
			
277		
0.06		
> .97	
			
	
	120	
	0.14	 17
	
5.29	
< 10	
B132IUNVHP-N
	>.96
0.90	
0/-18	1	-N
			277		
0.07	
18			 5.00	
< 15			
			
120	
0.17	
	
> .99	
	
	
	
	
B232IUNVHP-N	
21
1.07	5.10
< 10
0/-18	3a	-N
			
277		
0.08	
	
> .96	
	
		
		
			
120	
0.15	
	
> .99	
	
< 10	
	
B132PUNVHP-A2	
17
0.91	5.35
0/-18	2	-A
			
277		
0.07	
	
> .96	
	
	
< 15	
		
	1	 PS	
120	
0.23	
26	
> .99	
5.29	
	
	
B232PUNVHEH-A1	
1.38	
< 10 -20/-29	30	 -A
			
277		
0.11	
27	
> .94	
	
5.17 		
		
			
347	 ES1510A	
0.05	
18	
> .97	 0.87	
4.83	
< 10	 0/-18	
40	 ESA
F17T8 - Two Lamp Applications
			
120	 B232I120RES-G*	
0.49	
33	
> .50	 0.94	
2.85	
< 140	 0/-18	
3	
-G
			
120	 B232I120RES-A*	
0.49	
32	
> .50	 0.94	
2.94	
< 140	 0/-18	
3	
-A
			
347	 B232I347HP-A	
0.09	
32	
> .95	 0.92	
2.88	
< 10	 0/-18	
3	
-A
			
347	 B232I347HPL	
0.09	
29	
> .98	 0.79	
2.72	
< 10	 0/-18	
3	
ST
			
120	
	0.30	 	
> .99	
	
	
	
	
	
B232IUNV104-A
36
1.04
2.78
< 10
0/-18
3
-A
			
277	
	
0.15	
	
> .88	
	
		
	
	
			
120	
	0.27		
	
	
	
	
	
	
2	PAR-IS
B232IUNV-C
31
> .98
0.91
2.94
< 10
0/-18
21
-C
	
	 277	
	
0.12	
		
	
		
	
	
			
120	
	0.21	 25	
	
	3.20	 	
B232IUNVEL-A2
> .95
0.80
< 10
0/-18	3	 -A
			
277		
0.10	 26			
3.08
			
120	
	TBD	 TBD	
	
	TBD	 	
B232IUNVEL-N2
TBD
TBD
TBD
TBD	 TBD	TBD
			
277		
TBD	 TBD			
TBD
			
120	
	0.24	
B232IUNVHE-A2
30	
> .95	 0.90	
3.00	
< 10	 0/-18	
3	
-A
			
277		
0.12	
			
120	
	0.26	 	
> .99	
	
	
	
	
	
	
B232IUNVHP-N
31
0.89
2.87
< 10
0/-18
3
-N
			
277		
0.11		
> .98			
			
			
120	
	0.33	 41	
	2.88	
B232IUNVHEH-A
> .95	 1.18
< 10	 -20/-29	
3	
-A
			
277		
0.15	 40			
2.95

F17T8

• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options

TRIAD® ELECTRONIC BALLASTS
FOR (3) & (4) F17T8 LAMPS

Fluorescent-Electronic

• 3-4 Lamp Applications
Lamp				
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
	
		 Starting	 Line	
Catalog	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
Qty.	 Method	 Volts	
Number	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
F17T8 - Two Lamp Applications
2		 SER-PS	 347	 ES1329 A	
0.11	
36	
> .97	 0.87	
2.42	
< 10	 0/-18	
37	 ESA
			
120	
	
.22	
26	
> .99
	2.80	
B232PUNVEL-B
	0.74
< 10	 -20/-29	 30	
-B
			
277		
.11	
25	
> .92		
2.96	
	120	
	.25	 	
	
	
		
B232PUNVHE-B
30
> .90	 0.90
3.00
< 10	 -20/-29	 30	
-B
			277		
.12				
		
120	
	.35	
	
> .99
	2.95	
2
PAR-PS	
B232PUNVHEH-A
41
	1.20
< 10	 -20/-29	 30	
-A
			 277		
.16		> .97		 2.93
	120	
	.38	
	
	
	
		
B332PUNVHEH-A1
46
> .98	 1.31
2.85
< 10	 -20/-29	 30	
-A
			277		
.17				
F17T8 - Three Lamp Applications
			
347	 B332I347HP	
0.14	
48	
> .98	 0.92	
1.92	
< 10	 0/-18	
6	
ST
	
	 347	 B332I347HPL	
0.12	
43	
> .99	 0.80	
1.85	
< 10	 0/-18	
6	
ST
			
120	
	
0.35	
42	
> .99	
	1.95	
B332IUNVEL-A
0.82
< 10	 0/-18	
6	
-A
			
3	PAR-IS
277		
0.15	
41	
> .95		
2.00
			
120	
	0.39	 	
> .99	
B332IUNVHE-A
46
0.92	
2.00	
< 10	 0/-18	
6	
-A
			
277		
0.17		
> .97		
			
120	
0.38	
	
> .99	
	
	
B332IUNVHP-A	
45
0.92
2.04
< 10	 0/-18	
6	
-A
			
277		
0.18		
> .90					
			
120	 B432I120RES-A*	
0.72	
51	
> .50	 1.00	
1.96	
< 135	 0/-18	
7a	
-A
			
120	
	0.31	 	
> .99
	1.99	
B332PUNVEL-A
37
	.74
< 10	 -20/-29	
49	
-A
			
277		
0.14	
	
> .94		
2.01
	120	
	0.37	44	
	2.05	
		
B332PUNVHE-A
> .90	
.91
< 10	 -20/-29	
49	
-A
	 	
	 277		
0.16	
43 			
2.14	
3 PAR-PS
	120	
	0.49	 59	
	2.02	
		
B332PUNVHEH-A
> .98	 1.19
< 10	 -20/-29	
49	
-A
			
277		
0.22	
58 			
2.04	
	120	
	
0.47	
56	
> .99
	2.04	
		
B432PUNVHEH-E
	1.14
< 10	 -20/-29	
49	
-E
			
277		
0.23	
58 	 > .91		
1.97	
F17T8 - Four Lamp Applications
			
120	 B432I120RES-A*	
0.84	
61	
> .50	 0.92	
1.51	
< 130	 0/-18	
7a	
-A
			
347 	 B432I347HP	
0.19	
62	
> .98	 0.92	
1.48	
< 10	 0/-18	
7a	
ST
	
	 347	 B432I347HPL	
0.17	
56	
> .97	 0.82	
1.46	
< 10	 0/-18	
7	
ST
			
120	
	
0.44	
53	
>
.98	
	1.49	
	
4	PAR-IS
B432IUNVEL-A
0.79
< 10	 0/-18	
7a	
-A
			
277		
0.20	
52	
> .95		
1.52	
			
120	
	
0.49	
59	
> .98	
	1.53	
B432IUNVHE-A
0.90
< 10	 0/-18	
7a	
-A
			
277		
0.22	
58	
> .95		
1.55
	120	
0.49	
59	
> .98
1.53	
	
		
B432IUNVHP-A	
	0.90	
< 10 0/-18	7a	 -A
			
277		
0.22	
58	
> .90		
1.55				
			
120	
	
0.42	
50	
> .99
	1.43	
B432PUNVEL-A
	0.72
< 10	 -20/-29	
50	
-A
			
277		
0.18	
49	
> .95		
1.47
	120	
	0.49	59	
	1.52	
	4	 PAR-PS
B432PUNVHE-A
> .90	 0.89
< 10	 -20/-29	
50	
-A
			
277		
0.22	
58			
1.54	
	120	
	
0.65	
77	
> .99
1.19	1.54	
		
B432PUNVHEH-E
	
< 10	 -20/-29	
50	
-E
			
277		
0.30	
79	
> .95	 1.20	
1.52	
* For Residential Use Only
1 Consult Lamp Manufacturers for applications with Ballast Factor > 1.20

PAGE 1-­14

See page 1-18 for Dimensions
and Wiring Diagrams

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS

• Standard & Low Profile
Designs Featured

FOR (1) & (2) F25T8 LAMP

• Instant & Programmed
Rapid Starting Options

F17T8F25T8

• 1-2 Lamp Applications
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.07	
25	
> .95	 0.90	
3.60	
< 10	 0/-18	
1	
ST
0.18	
	
> .98	
19
0.78	 4.11	 <10	0/-18	 1	 -A
0.09		
> .90	
0.20	
	
> .99	
23
0.89	 3.87	 <10	0/-18	 1	 -N
0.09		
> .98
0.20	
	
	
24
>.98
0.88	
3.67	
< 10	 0/-18	
1	
-N
0.09								
0.24	
	
> .99	
28
1.05	
3.75	
< 10	 0/-18	
3a	
-N
0.10		
> .98						
0.43	
28	
> .50	 1.08	
3.86	
< 150	 0/-18	
3a	
-A
0.43	
28	
> .50	 1.08	
3.86	
< 150	 0/-18	
3a	
-G
0.08	
26	
> .98	 0.88	
3.38	
< 10	 0/-18	
3a	
ST
0.24	
28	
> .98	 1.02	
3.64	
< 10	 0/-18	
21a	
-C
0.11	
						
0.07	
24	
> .97	 0.87	
3.63	
< 10	 0/-18	
40	
ESA
0.31	
	>.99	
3.70
37
1.36
	
	
< 10	 -20/-29	 30	
-A
0.14		 >.97	
	3.67				
0.20	
	
> .99	
24
0.91	
3.79	
< 10	 0/-18	
2	
-A
0.09		
> .98						
0.64	
46	
> .50	 0.92	
2.00	
< 130	 0/-18	
3	
-A
0.64	
46	
> .50	 0.92	
2.00	
< 140	 0/-18	
3	
-G
0.13	
46	
> .95	 0.89	
1.93	
< 10	 0/-18	
3	
-A
0.12	
41	
> .98	 0.75	
1.83	
< 10	 0/-18	
3	
ST
0.37	45	 	
2.00	
	
> .98
0.90	
< 10 0/-18	21	 -C
0.16	
44	
		
2.05	
			
0.43	
51	
> .99	
1.94	
	
1.04	
< 10 0/-18	3	 -A
0.20	
50	
> .93 		
1.98	
			
0.30	36	 	0.79	 2.19	
> .95
< 10	 0/-18	
3	
-A
0.14	37		0.80	2.18
TBD	
TBD	
	
	
TBD	
	
TBD
TBD
TBD
TBD	 TBD	 TBD
TBD	
TBD			
TBD
0.36	
44	
> .95	 0.88	
2.00	
< 10	 0/-18	
3	
-A
0.16	
0.37	44	 	
2.05	
	
> .99
0.90	
< 10 0/-18	3	 -N
0.16	
43	
		
2.09	
			
0.51	61	
	1.93	
> .95	 1.18
< 10	 20/-29	
3	
-A
0.22	 60			
1.97
0.14	
49	
> .97	 0.87	
1.78	
<10	 0/-18	
37	
ESA
0.30	
36	
> .99	
	2.06	
0.74
<10	-20/-29	 30	 -B
0.14	
35	
> .96		
2.12
0.35	42	 	
	2.14	
> .90
0.90
<10	-20/-29	 30	 -B
0.16	
41			
2.18		
0.50	
60	
> .99	
	1.98	
1.18
<10	-20/-29	 30	 -A
0.22	
59	
> .98		
1.99		
0.55	66	 	
	1.98	
> .98
1.31
<10	-20/-29	 30	 -A
0.24	
65			
2.00		

* For Residential Use Only
1 Consult lamp manufacturer for applications with ballast factor >1.20
2 Consult Universal for availability

PAGE 1-­15

See page 1-18 for Dimensions
and Wiring Diagrams

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
F25T8 - One Lamp Applications
			
347	 B132I347HP	
			
120	
B132IUNVEL-A	
			
277		
	 	
	120	
1
IS
B132IUNVHE-N	
			
277		
	120	
		
B132IUNVHP-N	
			277		
	120	
		
B232IUNVHP-N	
			
277		
	
120	 B232I120RES-A*	
	
	
			
120	 B232I120RES-G*	
	
347	 B232I347HPL	
	
	
			
120	
B232IUNV-C	
			
277		
			
347	 ES1510A	
	120	
		
B232PUNVHEH-A1	
	1	 PS	
277		
120	
			
B132PUNVHP-A	
			
277		
F25T8 - Two Lamp Applications
			
120	 B232I120RES-A*	
			
120	 B232I120RES-G*	
			
347	 B232I347HP-A	
			
347	 B232I347HPL	
			
120	
B232IUNV-C	
			
277		
			
120	
B232IUNV104-A	
	 2	 PAR-IS	 277		
			
120	
B232IUNVEL-A2	
			 277		
			
120	
	
B232IUNVEL-N2
			
277		
			
120	
B232IUNVHE-A	
			
277		
	120	
		
B232IUNVHP-N	
			
277		
			
120	
B232IUNVHEH-A	
			
277		
2		 SER-PS	 347	 ES1329A	
	120	
		
B232PUNVEL-B	
	 		
277		
	120	
		
B232PUNVHE-B	
2	 	 PAR-PS	 277		
	120	
		
B232PUNVHEH-A	
	 		
277		
	120	
		
B332PUNVHEH-A1	
	 		
277		

F25T8

• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options

TRIAD® ELECTRONIC BALLASTS
FOR (3) F25T8 LAMPS

Fluorescent-Electronic

• 3 Lamp Applications
Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
F25T8 - Three Lamp Applications
	
	
120	 B432I120RES-A*	
	 		
347	 B332I347HP	
	
	
	
347	 B332I347HPL	
	
	 	
	120	
3 PAR-IS
B332IUNVEL-A	
			
277		
			
120	
B332IUNVHE-A	
			
277		
	 		
120	
B332IUNVHP-A	
	 		
277		
	120	
	 	
B332PUNVEL-A	
	 3		
PAR-PS
277		
	120	
	 	
B332PUNVHE-A	
	 		
277		
	120	
	 	
B332PUNVHEH-A	
	 		
277		
	120	
	 	
B432PUNVHEH-E	
	 		
277		
  * For Residential Use Only

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.96	
71	
> .50	 0.98	
1.38	
< 130	 0/-18	
0.20	
68	
> .99	 0.91	
1.34	
< 10	 0/-18	
0.17	
60	
> .99	 0.76	
1.26	
< 10	 0/-18	
0.49	
59	
> .99	
	1.36	
0.80
< 10	 0/-18	
0.22	
58	
> .97		
1.38	
0.56	
67	
> .99	
	1.34	
0.90
< 10	 0/-18	
0.24	
66	
> .98		
1.36
0.55	
66	
> .99	
	1.36	
0.90
<10	0/-18	
0.25	
65	
> .90		
1.38	
0.46	
55	
> .99	
	1.34	
0.73
<10	-20/-29	
0.20	
54	
> .97		
1.36
0.53	63	 	
	1.40	
> .90
0.89
<10	-20/-29	
0.23	
62			
1.43
0.72	86	 	
	1.36	
> .98
1.18
<10	-20/-29	
0.31	
85			
1.38
0.69	
	
> .99	
	1.37	
82
1.13
<10	-20/-29	
0.31		
> .95		
1.38

7a	
6	
6	

-A
ST
ST

6	

-A

6	

-A

6	

-A

49	

-A

49	

-A

49	

-A

49	

-E

See page 1-18 for Dimensions and Wiring Diagrams

PAGE 1-­16

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS
FOR (3) & (4) F25T8 LAMPS

F25T8

• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
• 3-4 Lamp Applications

  * For Residential Use Only
1 Consult Lamp Manufacturers for applications with Ballast Factor > 1.20

PAGE 1-­17

See page 1-18 for Dimensions
and Wiring Diagrams

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

Lamp				
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
	
		 Starting	 Line	
Catalog	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
Qty.	 Method	 Volts	
Number	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
F25T8 - Four Lamp Applications				
	 		
120	 B432I120RES-A*	
1.13	
85	
> .50	 0.90	
1.06	
< 130	 0/-18	
7a	
-A
			
347	 B432I347HPL	
0.24	
83	
> .98	 0.78	
0.94	
< 10	 0/-18	
7	
ST
	
	120	
0.72	
87	
> .99	
	1.02	
	
B432IUNVHP-A	
0.89
< 10	 0/-18	
7a	
-A
	 		
277		
0.32	
85	
> .95		
1.05				
	 4 	 PAR-IS	 347	 B432I347HP	
0.26	
90	
> .98	 0.90	
1.00	
< 10	 0/-18	
7a	
ST
			
120	
	 0.65	78	
	1.00	
B432IUNVEL-A
> .98	 0.78
< 10	 0/-18	
7a	
-A
			
277		
0.28	 76			
1.03
			
120	
	
0.72	
87	
> .99	
	1.02	
B432IUNVHE-A
0.89
< 10	 0/-18	
7a	
-A
			
277		
0.31	
85	
> .98		
1.05
	120	
0.61	
73	
> .99	
	0.98	
		
B432PUNVEL-A	
0.72
<10	-20/-29	 50	 -A
	 		
277		
0.27	
72	
> .97		
1.00
4 PAR-PS
	120	
0.73	87	 	
	1.01	
	 	
B432PUNVHE-A	
> .90
0.88
<10	-20/-29	 50	 -A
			
277		
0.31	 84			
1.04
	120	
0.94	
112	 > .99	
	1.06	
	 	
B432PUNVHEH-E	
1.18
<10	-20/-29	 50	 -E
	 		
277		
0.91	
108	 > .95		
1.09
F25T8ES (22W) - One Lamp Applications				
	120	
0.16	
	
> .99	
	
	
	
B132IUNVHE-N	
19
0.89
4.68
<10	60/16	 3a	 -N
	 		
277		
0.07		
> .98		
1	IS
	120	
0.20	
	
>
.99	
	
	
	 	
B232IUNVHP-N	
24
1.14
4.74
<10	60/16	 3a	 -N
	 		
277		
0.09		
> .98		
F25T8ES (22W) - Two Lamp Applications				
0.31	37	 	
	2.43	
	 2	IS	120	
B232IUNVHP-N	
> .99
0.89
<10	60/16	 3	 -N
	 		
277		
0.13	
36			
2.46

F17T8
&
F25T8

TRIAD® ELECTRONIC BALLASTS
FOR F17T8 & F25T8 LAMPS

	 Overall Dimensions	
	Draw #	
L	
	ST	
	-A	
	-B	
	-C	
	-G	
	-N	
	ESA	

W	

9.50”	
9.50”	
9.50”	
14.25”	
9.50”	
9.50”	
9.50”	

2.40”	
1.70”	
1.50”	
1.18”	
1.18”	
1.30”	
1.56”	

Mounting Dimensions
H	
M	
X

1.55”	
1.18”	
1.00”	
1.00”	
1.00”	
1.00”	
1.00”	

8.89”	
8.89”	
8.89”	
13.75”	
8.89”	
8.89”	
8.88”	

1.69”
1.69”
0.88”
------0.78”

ST

-A, -B, -G, ESA, -N

-C

Fluorescent-Electronic

WIRING DIAGRAMS

DIAGRAM 1

Line

Black
White

BALLAST

DIAGRAM 2

DIAGRAM 3

DIAGRAM 3a

Blue
Blue
Blue
Red

LAMP
LAMP
LAMP

For three lamp operation, cap
any blue lead, insulate to 600V

DIAGRAM 7

DIAGRAM 6

DIAGRAM 7a

DIAGRAM 21

DIAGRAM 8

DIAGRAM 21a

DIAGRAM 37
For one lamp operation, individually
cap blue leads, insulate to 600V

DIAGRAM 30
DIAGRAM 40

DIAGRAM 49
DIAGRAM
49

DIAGRAM 5050
DIAGRAM

PAGE 1-­18

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS
FOR (1) F32T8 LAMP

F32T8

• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
• 1 Lamp Applications

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.25	
	
30
> .98	 0.88	
2.93	
< 10	 0/-18	
1	
-N
0.11
			
		
0.09	
31	
> .98	 0.88	
2.84	
< 10	 0/-18	
1	
ST
0.22	
	
> .98	
25
0.77	
3.08	
< 10	 0/-18	
1	
-A
0.11		
> .95
0.25	
	
	
28
> .99
0.87	
3.11	
< 10	 0/-18	
1	
-N
0.11			
0.53	
35	
> .50	 1.06	
3.03	
< 135	 0/-18	
3	
-A
0.53	
36	
> .50	 1.06	
2.94	
< 150	 0/-18	
3	
-G
0.09	
32	
> .98	 0.91	
2.84	
< 10	 0/-18	
3	
ST
0.29	
35	
> .99	
2.99
1.04	
	
< 10	 0/-18	3	 -N
0.13	
34	
> .98		
3.03	
			
0.11	
36	
> .95	 1.05	
2.92	
< 10	 0/-18	
3	
-A
0.29	
	
	
35
> .98	 1.02	
2.91	
< 10 0/-18	22	 -C
0.13					
			
0.24	
30	
> .95	 0.95	
3.17	
< 10	 0/-18	
3	
-A
0.11	
0.26	31
2.95
	
> .95	 0.91	
	
< 10	 0/-18	
3	
-N
0.11	 30			
2.98
0.28	
33	
> .95	 1.05	
3.18	
< 10	 0/-18	
3	
-A
0.13
0.39	47	
	2.94	
> .95	 1.38
< 10	 -20/-29	
3	
-A
0.18	 46			
3.00
0.26	
31	
> .99
2.84
	0.88	
	
< 10	 0/-18	
2	
-A
0.11
30
> .98		
2.93				
	
	
0.09	
31	
> .97	 0.87	
2.81	
< 10	 0/-18	
40	
ESA
0.29	35	 	
	2.90	
> .90
1.01
<10	-20/-29	 30	 -B
0.13	
34			
2.98
0.24	
29	
> .99	
	2.88	
0.83
<10	-20/-29	 30	 -B
0.12	
28	
> .93		
3.02
0.40	
	
	
	
	
47
> .99
1.34
2.86
<10	-20/-29	 30	 -A
0.18					
	

* For Residential Use Only
1 Consult Lamp Manufacturers for applications with Ballast Factor > 1.20
2 Consult Universal for availability

IS = Instant Start
PS = Programmed Start

RS = Rapid Start
PAR-IS = Parallel Instant Start

STARTING METHOD LEGEND

PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start

PAGE 1-­19

See page 1-23 for Dimensions
and Wiring Diagrams
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start

SER-IS = Series Instant Start

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

	 	 Lamp				
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
F32T8 - One Lamp Applications
	 		
120	
B132IUNVHP-N	
		
277		
	
	 		
347	 B132I347HP	
			
120	
B132IUNVEL-A	
			
277		
			
120	
B132IUNVHE-N	
			
277		
			
120	 B232I120RES-A*	
	 	
	
120	 B232I120RES-G*	
1
IS
	 		
347	 B232I347HPL	
	120
		
	B232IUNVHP-N	
		
277		
	
			
347	 B232I347HP-A	
	
120
		
	B232IUNV-C	
		
277		
	
			
120	
B232IUNVEL-A2	
			
277		
			
120	
B232IUNVEL-N	
			
277		
			
120	
B232IUNVHE-A	
			
277		
			
120	
B232IUNVHEH-A1	
			
277		
	
	120	
	
B132PUNVHP-A	
	
	
277		
	
			
347	 ES1510A	
1		
PS	120	
B232PUNVHE-B	
	 		
277		
	120	
		
B232PUNVEL-B	
	 		
277		
	120	
		
B232PUNVHEH-A1	
	 		
277		

F32T8

• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options

TRIAD® ELECTRONIC BALLASTS
FOR (2) F32T8 LAMPS

Fluorescent-Electronic

• 2 Lamp Applications
Lamp				
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
	
		 Starting	 Line	
Catalog	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
Qty.	 Method	 Volts	
Number	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
F32T8 - Two Lamp Applications
			
120	 B232I120RES-A*	
0.80	
56	
> .50	 0.88	
1.57	
< 120	 0/-18	
3	
-A
	 		
120	 B232I120RES-G*	
0.80	
56	
> .50	 0.88	
1.57	
< 130	 0/-18	
3	
-G
			
347	 B232I347HPL	
0.14	
50	
> .99	 0.78	
1.56	
< 10	 0/-18	
3	
ST
			
120
0.47	
	
	
	B232IUNVHP-N	
55
> .99	 0.86
1.58	
< 10	 0/-18	
3	
-N
	 		
277		
0.20		
			
	
		
			
347	 B232I347HP-A	
0.17	
58	
> .99	 0.88	
1.52	
< 10	 0/-18	
3	
-A
	 		
120
0.48	58
1.52
	
	B232IUNV-C	
	
> .98	 0.88
	
< 10	 0/-18	
21	
-C
	 		
277		
0.20	
56	
1.57				
		
			
120	
0.54	65
> .99
1.57
B232IUN104-A	
	
	1.04	
	
< 10	 0/-18	
3	
-A
			
277		
0.24	
64	
> .95		
1.59
			
120	
0.40	
B232IUNVEL-A2	
48	
> .95	 0.77	
1.60	
< 10	 0/-18	
3	
-A
			
277		
0.17	
			
120	
0.42	49
0.77
B232IUNVEL-N	
	
> .95	
	
1.60	
< 10	 0/-18	
3	
-N
			
277		
0.18	 48		 0.76
	2	 PAR-IS	 120	
0.45	55	
	1.58	
B232IUNVHE-A	
> .95	 0.87
< 10	 0/-18	
3	
-A
			
277		
0.20	 54			
1.61
			
120	
0.62	74	
	1.59	
B232IUNVHEH-A	
> .95	 1.18
< 10	 -20/-29	
3	
-A
			
277		
0.26	 73			
1.62
	
	347	
0.22	
	
> .97	
	
B332IHRVHB-E1	
76
1.22	
1.61	
< 10	 -20/-29	46	 -E
			
480		
0.17		
> .90
			
347	 B332I347HPL	
0.16	
56	
> .99	 0.87	
1.55	
< 10	 0/-18	
6	
ST
			
120	
0.53	
	
> .99	
B332IUNVHP-A	
63
0.99	1.57	
< 10	 0/-18	
6	
-A
			
277		
0.24		
> .95				
			
347	 B332I347HP	
0.19	
66	
> .99	 0.99	
1.50	
< 10	 0/-18	
6	
ST
			
120	
0.48	
57	
> .99	
	1.56	
B332IUNVEL-A	
0.89
< 10	 0/-18	
6	
-A
			
277		
0.21	
56	
> .97		
1.59
			
120	
0.53	
64	
> .99	
	1.55	
B332IUNVHE-A	
0.99
< 10	 0/-18	
6	
-A
			
277		
0.23	
63	
> .98		
1.57
* For Residential Use Only
1 Consult Lamp Manufacturers for applications with Ballast Factor > 1.20
2 Consult Universal for availability

PAGE 1-­20

See page 1-23 for Dimensions
and Wiring Diagrams

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS

F32T8

• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options

FOR (2) & (3) F32T8 LAMPS

• 2 & 3 Lamp Applications
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.17	
59	
> .97	 0.87	
1.47	
<10	 0/-18	
0.46	55	 	
	1.59	
> .90
0.88
<10	-20/-29	
0.20	
54			
1.64
0.38	
46	
> .99	
	1.56	
0.71
<10	-20/-29	
0.16	
44	
> .97		
1.60
0.65	77	 	
	1.52	
> .99
1.17
<10	-20/-29	
0.28	
76			
1.54
0.54	65	 	
	1.59	
> .90
1.03
<10	-20/-29	
0.24	
64			
1.61
0.44	
53	
> .99	
	1.65	
0.87
<10	-20/-29	
0.20	
52	
> .96		
1.68
0.70	84	 	
	1.54	
> .99
1.30
<10	-20/-29	
0.30	
83			
1.57
0.32	
0.24	
0.21	
0.71	
0.31	
0.25	
0.61	
0.26	
0.70	
0.30	
1.20	
0.24	
0.77	
0.34	
0.28	
0.67	
0.29	
0.74	
0.32	

110	
109	
75	
84	
83	
88	
74	
73	
83	
81	
92	
83	
92	
89	
92	
80	
78	
89	
87	

37	

ESA

30	

-B

30	

-B

30	

-A

30	

-A

30	

-A

30	

-A

> .98	
	1.07	
	
1.18
< 10	 -20/-29	 46	
-E
> .95		
1.08
> .99	 0.79	
1.05	
< 10	 0/-18	
6	
ST
> .99	
	1.05
0.88
	
< 10	 0/-18	
6	
-A
> .98		
1.06					
> .99	 0.88	
1.00	
< 10	 0/-18	
6	
ST
> .99	
	1.04	
0.77
< 10	 0/-18	
6	
-A
> .98		
1.05
> .99	
	1.05	
0.87
< 10	 0/-18	
6	
-A
> .98		
1.07
> .50	 0.96	
1.04	
< 130	 0/-18	
7a	
-A
> .98	 0.87	
1.05	
< 10	 0/-18	
7	
ST
> .99	
1.02	
	
0.94	
< 10 0/-18	7a	 -A
> .95		
1.06				
> .98	 0.99	
1.08	
< 10	 0/-18	
7a	
ST
> .99	
	1.08	
0.86
< 10	 0/-18	
7a	
-A
> .98		
1.10	
> .99	
	1.06	
0.94
< 10	 0/-18	
7a	
-A
> .98		
1.08

* For Residential Use Only
1 Consult lamp manufacturers for applications with Ballast Factor > 1.20
2 Consult Universal for Availability

PAGE 1-­21

See page 1-23 for Dimensions
and Wiring Diagrams

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

Lamp				
	
		 Starting	 Line	
Catalog	
Number	
	 Qty.	 Method	 Volts	
F32T8 - Two Lamp Applications
	 2	 SER-PS	 347	 ES1329A	
	120	
	 	
B232PUNVHE-B	
	 		
277		
	120	
		
B232PUNVEL-B	
	 		
277		
	120	
		
B232PUNVHEH-A	
	 		
277		
	 2	PAR-PS	120	B332PUNVHE-A	
	 		
277		
	120	
		
B332PUNVEL-A	
	 		
277		
	120	
		
B332PUNVHEH-A1	
	 		
277		
F32T8 - Three Lamp Applications
	 3	SER-IS 	 347	
B332IHRVHB-E	
			
480		
		
	
347	 B332I347HPL	
	 	
	120	
B332IUNVHP-A	
	 		
277		
	 		
347	 B332I347HP	
			
120	
B332IUNVEL-A	
			
277		
			
120	
B332IUNVHE-A	
	 3	 PAR-IS	 277		
	
	
120	 B432I120RES-A*	
	
	 		
347	 B432I347HPL	
	
	120	
	
B432IUNVHP-A	
	
	
277		
	 		
347	 B432I347HP	
	 		
120	
B432IUNVEL-A	
			
277		
			
120	
B432IUNVHE-A	
			
277		

F32T8

• Low Profile
Designs Featured

TRIAD® ELECTRONIC BALLASTS

• Instant & Programmed
Rapid Starting Options

FOR (3) & (4) F32T8 LAMPS

Fluorescent-Electronic

• 4 Lamp Applications
Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
F32T8 - Three Lamp Applications
	120	
	 	
B332PUNVHE-A	
	 		
277		
	120	
		
B332PUNVEL-A	
	 		
277		
	120	
		
B332PUNVHEH-A	
	
	 277		
3	PAR-PS
	120	
		
B432PUNVHE-A	
	 		
277		
	120	
		
B432PUNVEL-A	
	 		
277		
	120	
		
B432PUNVHEH-E	
	 		
277		
F32T8 - Four Lamp Applications
			
120	 B432I120RES-A*	
	
	
347	 B432I347HPL	
	 			
120	
4 	 PAR-IS
B432IUNVHP-A	
	
	 277		
	 		
347	 B432I347HP	
	 		
120	
B432IUNVEL-A	
			
277		
			
120	
B432IUNVHE-A	
			
277		
	120	
	4	 PAR-PS
B432PUNVHE-A	
	 		
277		
	120	
		
B432PUNVEL-A	
	 		
277		
	120	
		
B432PUNVHEH-E	
	 		
277		

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.70	84	 	
	1.05	
> .90
0.88
<10	-20/-29	
0.30	
82			
1.07
0.58	
70	
> .99	
	1.02	
0.71
<10	-20/-29	
0.25	
69	
> .98		
1.03
0.93	112	 	
	1.03	
> .99
1.15
<10	-20/-29	
0.40	
109			
1.06
0.75	90	 	
	1.06	
> .90
0.95
<10	-20/-29	
0.32	
87			
1.09
0.66	
79	
> .99	
	0.97	
0.77
<10	-20/-29	
0.29	
77	
> .97		
1.00
0.87	
103	 > .99	
	1.08	
1.12
<10	-20/-29	
0.38	
102	 > .97		
1.10

49	

-A

49	

-A

49	

-A

49	

-A

49	

-A

49	

-A

1.40	
109	 > .50	 0.87	
0.80	
< 130	 0/-18	
7a	
0.29	
101	 > .99	 0.78	
0.77	
< 10	 0/-18	
7	
0.93	
110	 > .99	
0.80	
	
0.88
< 10	 0/-18	
7a	
0.40	
108	 > .98 		
0.81				
0.33	
114	 > .99	 0.88	
0.77	
< 10	 0/-18	
7a	
0.80	
97	
> .99	
	0.79	
0.77
< 10	 0/-18	
7a	
0.34	
96	
> .98		
0.80
0.91	109	
	0.80	
> .99	 0.87
< 10	 0/-18	
7a	
0.38	 106			
0.82	
0.91	109	 	
	0.80	
> .90
0.87
<10	-20/-29	 50	
0.39	
107			
0.82
0.76	
91	
> .99	
	0.78	
0.71
<10	-20/-29	 50	
0.33	
90	
> .98		
0.79
1.20	
143	 > .99	
	0.81	
1.15
<10	-20/-29	 50	
0.50	
141	 > .98		
0.82

-A
ST

  * For Residential Use Only
2 Consult Universal for Availability

IS = Instant Start
PS = Programmed Start

RS = Rapid Start
PAR-IS = Parallel Instant Start

-A
ST
-A
-A
-A
-A
-E

See page 1-23 for Dimensions and Wiring Diagrams

STARTING METHOD LEGEND

PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start

PAGE 1-­22

PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start

SER-IS = Series Instant Start

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS

F32T8

FOR F32T8 LAMPS

	 Overall Dimensions	
	Draw #	
L	

	ST	 9.50”	
	-A	 9.50”	
	-B	 9.50”	
	-C	 14.25”	
	-E	 16.88”	
	-G	 9.50”	
	 -N	 9.50”	
	ESA	 9.50”	

W	

Mounting Dimensions
H	
M	
X

2.40”	 1.55”	 8.89”	 1.69”
1.70”	 1.18”	 8.89”	 1.69”
1.50”	 1.00”	 8.89”	 0.88”
1.18”	 1.00”	 13.75”	 --1.74”	 1.18”	 16.28”	 --1.18”	 1.00”	 8.89”	 --1.30”	 1.00”	8.89”	 ---	
1.56”	 1.00”	8.88”	0.78”

ST

-A, -B, -E, -G ESA, -N

-C

WIRING DIAGRAMS

Line

Black
White

BALLAST

For one lamp operation, individually
cap unused blue lead, insulate to 600V

DIAGRAM 2

Blue
Blue
Blue
Red

Line

Black
White
Yellow

DIAGRAM 3

Blue

BALLAST

Blue
Red
Red

Yellow

LAMP

Fluorescent-Electronic

DIAGRAM 1

LAMP

LAMP
LAMP

LAMP
LAMP
LAMP

For Two Lamp operation,
Insulate one blue lead to 600V

For Three Lamp Operation,
Insulate one blue lead to 600V

For three lamp operation, cap any
blue lead, insulate to 600V

DIAGRAM 6

DIAGRAM 7

DIAGRAM 7a

DIAGRAM 21

DIAGRAM 30

DIAGRAM 22

DIAGRAM 46

DIAGRAM 37

DIAGRAM 40

DIAGRAM 49
DIAGRAM
49

PAGE 1-­23

DIAGRAM 50

DIAGRAM 50

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

F32T8ES
30 WATT

• High Performance
Models and Low Profile
Designs

TRIAD® ELECTRONIC BALLASTS

• Instant and Programmed
Rapid Starting Options

FOR (1) & (2) F32T8ES(30 WATT) LAMPS

Fluorescent-Electronic

• 1-2 Lamp Applications
Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
F32T8ES(30W) - One Lamp Applications
			
120	
			
277		B132IUNVEL-A	
			
120	
1
IS
B132IUNVHE-N	
	 	
	 277		
			
120	
B132IUNVHP-N	
	
	
277		
			
347	 B232I347HP-A	
	
			
120	
B232IUNVEL-A2	
			
277		
			
120	
B232IUNVEL-N	
			
277		
			
120	
B232IUNVHE-A	
			
277		
			
120	
			
277		B232IUNVHP-N	
			
120	
B232IUNVHEH-A1	
			
277		
	 	
	120	
			
277		B132PUNVHP-A	
	120	
		
B232PUNVEL-B	
	 1	
PS	
277		
	120	
	 	
B232PUNVHE-B	
	 		
277		
	120	
	 	
B232PUNVHE-B	
	 		
277		
		
120	
	
B232PUNVHEH-A1	
	 		
277		
F32T8ES(30W) - Two Lamp Applications
	
	347	
1
2	SER-IS
			
480		B332IHRVHB-E 	
			
120	
			
277		B332IUNV104-A	
			
120	
B232IUNVEL-A2	
			
277		
			
120	
B232IUNVEL-N	
			
277		
			
120	
B232IUNVHP-N	
			
277		
	 	
	120	
2 PAR-IS
B232IUNVHE-A	
			
277		
			
120	
B232IUNVHEH-A	
			
277		
			
347	 B232I347HP-A	
	
	120	
	
			
277		B332IUNVEL-A	
			
120	
			
277		B332IUNVHE-A	
			
120	
			
277		B332IUNVHP-A	

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.22	
	
> .98	
	
25
0.77	
3.08	
< 10
0.11		
> .95
0.24	
	
	
26
> .99
0.87	
3.35	
< 10	
0.10		
0.24	
	
	
	
28
> .98
0.88	
3.14	
< 10
0.10		
0.10	
34	
> .98	 1.04	
3.06	
< 10	
0.23	
28	
>
.95	
0.92	
3.92	
<
10	
0.11
0.24	
0.89
3.04
29	
> .95	 0.88	
	
< 10	
0.10			
3.08	
0.25	
> .95	 1.05	
3.28	
< 10	
0.12	 32	
0.27	
33	
> .99	 1.02	
3.14	
< 10	
0.12	
32	
> .98	 1.03	
3.21
0.37	
	
	
	
	
43
> .95
1.38
3.21
< 10	
0.16
0.23	
	
> .99	
28
3.14	
< 10	
0.10		
> .98	 0.88	
0.23	
28	
> .99	
	3.01	
0.83
<10	
0.12	
27	
> .93		
3.12
0.27	32	 	
	3.12	
> .90
1.01
<10	
0.12	
30			
3.34
0.27	32	 	
	3.12	
> .90
1.01
<10	
0.12	
30			
3.34
0.38	
	
	
	
	
47
> .98
1.34
2.85
<10	
0.17				
0.21	
	
> .97	
71
1.22	
1.72	
< 10	
0.16		
> .90
0.50	
	
> .99	
	1.72	
61
1.04
< 10	
0.23		
> .94		
1.75
0.38	
> .95	 0.77	
1.67	
< 10	
0.17	 46	
0.40	
	
	
	1.57	
47
> .95
0.75
< 10	
0.17				
1.60
0.44	53	 	
	1.64	
> .99
0.86
< 10	
0.19	 51			
1.69
0.42	52	
	1.67	
> .95	 0.87
< 10	
0.19	 51			
1.71
0.59	70	
	1.69	
> .95	 1.18
< 10	
0.25	 68			
1.74
0.15	
53	
> .98	 0.88	
1.66	
< 10	
0.46	
54	
> .99	
	1.65	
0.89
< 10	
0.20	
53	
> .98		
1.68
0.49	
59	
> .99	
	1.68	
0.99
< 10	
0.21	
57	
> .97		
1.74
0.50	
	
> .99	
	
	
59
0.99
1.68
< 10	
0.22		
> .95

1 Consult lamp manufacturers for applications with Ballast Factor > 1.20
2 Consult Universal for availability

PAGE 1-­24

60/16	1	 -A
60/16	

1	

-N

60/16	1	 -N
60/16	
3a	
-A

60/16	

3a	

-A

60/16	

3a	

-N

60/16	

3a	

-A

60/16	

3a	

-N

60/16	

3a	

-A

60/16	

2	

-A

60/16	30	 -B
60/16	30	 -B
60/16	30	 -B
60/16	30	 -A
60/16	

46	

-E

60/16	

3	

-A

60/16	

3	

-A

60/16	

3	

-N

60/16	

3	

-N

60/16	

3	

-A

60/16	
60/16	

3	
3	

-A
-A

60/16	

6	

-A

60/16	

6	

-A

60/16	

6	

-A

See page 1-31 for Dimensions
and Wiring Diagrams

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

F32T8ES

TRIAD® ELECTRONIC BALLASTS

30 WATT

FOR (2)(cont.), (3) & (4) F32T8ES LAMPS

and Wiring Diagrams

PAGE 1-­25

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

Lamp				
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
	
		 Starting	 Line	
Catalog	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
Qty.	 Method	 Volts	
Number	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
F32T8ES(30W) - Two Lamp Applications
	120	
0.36	
43	
> .99	
	1.64	
		
B232PUNVEL-B	
0.71
<10	 60/16	30	 -B
	 		
277		
0.15	
42	
> .97		
1.71
	120	
0.42	50	 	
	1.75	
		
B232PUNVHE-B	
> .90
0.88
<10	 60/16	30	 -B
	 	
	 277		
0.18	 48			
1.82
2 PAR-PS
	120	
0.61	75	
	
	1.68	
		
B232PUNVHEH-A1	
> .99
1.26
<10	 60/16	30	 -A
	
	
277		
0.26	 74			
1.70
	
	120	
0.41	
49	
>
.99	
	1.77	
		
B332PUNVEL-A	
0.87
<10	 60/16	30	 -A
	 		
277		
0.18	
48	
> .96		
1.82
	120	
0.50	60	 	
	1.72	
		
B332PUNVHE-A	
> .90
1.03
<10	 60/16	30	 -A
	 		
277		
0.22	
59			
1.73
	120	
0.66	82	
	
	1.59	
		
B332PUNVHEH-A1	
> .99
1.30
<10	 60/16	30	 -A
	
	
277		
0.29	 81			
1.60
	
F32T8ES(30W) - Three Lamp Applications
	
	347	
0.30	
102	 > .98	
	1.16	
3	SER-IS
B332IHRVHB-E	
1.18
< 10	 60/16	
46	
-E
			
480		
0.22	
101	 > .95		
1.17
	
	120	
0.58	
70	
> .99	
	1.10	
	
B332IUNVEL-A	
0.77
< 10	 60/16	
6	
-A
			
277		
0.25	
69	
> .98		
1.12
			
120	
0.65	
79	
> .99	
	1.10	
B332IUNVHE-A	
0.87
< 10	 60/16	
6	
-A
			
277		
0.28	
77	
> .98		
1.13
	 	
	120	
0.66	
79	
> .99	
	1.13	
3 PAR-IS
B332IUNVHP-A	
0.89
< 10	 60/16	
6	
-A
			
277		
0.29	
77	
> .95		
1.16
			
347	 B432I347HP	
0.26	
88	
> .98	 0.99	
1.13	
< 10	 60/16	
7a	
ST
			
120	
0.62	
75	
> .99	
	1.15	
B432IUNVEL-A	
0.86
< 10	 60/16	
7a	
-A
			
277		
0.27	
73	
> .98		
1.18
			
120	
0.70	84	
	1.14	
B432IUNVHE-A	
> .98	 0.96
< 10	 60/16	
7a	
-A
			
277		
0.30	 82			
1.17
			
120	
0.72	
86	
> .98	
	1.12	
B432IUNVHP-A	
0.96
< 10	 60/16	
7a	
-A
			
277		
0.32	
84	
> .95		
1.14
	120	
0.53	
64	
> .99	
	
1.12	
		
B332PUNVEL-A	
0.71
<10	 60/16	49	 -A
	 		
277		
0.23	
63	
> .97		
1.13
	120	
0.89	106	 	
	1.08	
		
B332PUNVHEH-A	
> .99
1.15
<10	 60/16	49	 -A
	
	
277		
0.38	 104			
1.11
	
	120	
0.65	78	 	
	
1.13	
		
B332PUNVHE-A	
> .90
0.88
<10	 60/16	49	 -A
	 	
	 277		
0.28	 76			
1.15
3 PAR-PS
	120	
0.60	
72	
> .99	
	
1.07	
		
B432PUNVEL-A	
0.77
<10	 60/16	49	 -A
	 		
277			 0.26	
71	
> .97		
1.09
	120	
0.74	89	 	
	
1.07	
		
B432PUNVHE-A	
> .90
0.95
<10	 60/16	49	 -A
	 		
277		
0.31	
84			
1.13	
	120	
0.84	
99	
> .99	
	1.14	
		
B432PUNVHEH-E	
1.13
<10	 60/16	49	 -E
	
	
277		
0.37	
98	
> .96		
1.15
	
1 Consult lamp manufacturers for applications with Ballast Factor > 1.20
See page 1-31 for Dimensions

F32T8ES

(30W -25W)

• High Performance
Models and Low Profile
Designs
• 1-2 Lamp Applications

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	

Fluorescent-Electronic

TRIAD® ELECTRONIC BALLASTS

F32T8ES(30W) - Four Lamp Applications
			
347	 B432I347HP	
			
120	
B432IUNVEL-A	
	 	
	 277		
4 PAR-IS
			
120	
B432IUNVHE-A	
			
277		
			
120	
B432IUNVHP-A	
			
277		
	120	
		
B432PUNVEL-A	
	 	
	 277		
4 PAR-PS
	120	
		
B432PUNVHE-A	
	 		
277		
	120	
		
B432PUNVHEH-E	
	 		
277		
F32T8ES (25W) - One Lamp Applications
			
120	
B132IUNVEL-A	
			
277		
	
	120	
1	IS
B132IUNVHE-N	
			
277		
			
120	
B132IUNVHP-N 	
			
277		
	
	120	
	
B232IUNVEL-A2	
			
277		
			
120	
B232IUNVEL-N	
			
277		
			
120	
B232IUNVHE-A	
			
277		
			
120	
B232IUNVHP-N 	
			
277		
			
120	
B232IUNVHEH-A1	
			
277		
	
	120	
	
B132PUNVHP-A	
	
	
277		
	
	120	
		
B232PUNVEL-B	
	 	
	 277		
1
PS
	120	
	 	
B232PUNVHE-B	
	 		
277		
	120	
	 	
B232PUNVHEH-A1	
	 		
277		
F32T8ES (25W) - Two Lamp Applications
	
	347	
2	SER-IS
B332IHRVHB-E	
			
480		
			
120	
B232IUNV104-A 	
			
277		
			
120	
2
			
277		B232IUNVEL-A 	
	
	120	
	
B232IUNVEL-N	
			
277		
	
	120	
	
B232IUNVHE-A	
			
277		
			
120	
B232IUNVHP-N 	
	 	
	 277		
2 PAR-IS
			
120	
B232IUNVHEH-A	
			
277		
	
	120	
	
B332IUNVEL-A	
			
277		
			
120	
B332IUNVHE-A	
			
277		
	
120	
		
B332IUNVHP-A 	
			
277		

FOR (1) & (2)
F32T8ES (25 WATT) LAMPS

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.31	
106	 > .99	 0.88	
0.83	
< 10	
0.75	
91	
> .99	
	0.85	
0.77
< 10	
0.32	
90	
> .98		
0.86
0.85	
103	 > .99
	0.84	
	0.87
< 10	
0.36	
100	 > .98		
0.87
0.87	
104	 > .98	
	0.85	
0.88
< 10	
0.38	
101	 > .95		
0.87	
0.71	85	
> .99	
	0.83	
0.71
<10	
0.31	 84	 > .98		 0.84
0.86	103	 	
	0.84	
> .90
0.87
<10	
0.37	
101			
0.86
1.14	135	
> .99	
	0.87	
1.18
<10	
0.50	
134	 > .97		 0.88

60/16	

7a	

ST

60/16	

7a	

-A

60/16	

7a	

-A

60/16	

7a	

-A

60/16	50	 -A
60/16	50	 -A
60/16	50	 -E

0.17	
	
> .98	
20
0.77	
3.85	
< 10	 60/16	
1	
0.07		
> .95
0.20	
	
	
23
> .99
0.87	
3.78	
< 10	 60/16	
1	
0.09		
0.20	
	
	
24
> .98
0.88	
3.67	
< 10	 60/16	
1	
0.09		
0.20	
24	
> .99	
3.96
< 10
0.95	
	
	60/16	 3a	
0.09	
25	
> .95		
3.80	
< 15
0.20	
	
> .99	 0.84
3.54
< 10
24
	
	
	60/16	 3a	
0.09		
> .95	 0.85	
3.55	
< 15
0.23	
	
> .98	
27
1.05	
3.89	
< 10	 60/16	
3a	
0.10		
> .95
0.22	
27	
> .99	
	3.60	
0.96
< 10	 60/16	
3a	
0.10	
26	
> .98		
3.64
0.32	38	
	3.63	
> .95	 1.38
< 10	 60/16	
3a	
0.14	 37			
3.73
0.21	
	
	
	
25
> .99	 0.88
3.52
< 10	 60/16	
2	
0.09				
0.20	24	
> .99	
	3.49	
0.83
<10	 60/16	30	
0.11	 23	 > .92		
3.58
0.23	28	 	
	3.80	
> .90
1.05
<10	 60/16	30	
0.12	
27			
3.88
0.33	
	
	1.36	 3.81	
36
> .98
<10	 60/16	30	
0.14			
1.35	
3.72
0.18	
	
> .95	
61
1.14	
1.87	
< 10	
0.14		
> .90
0.42	
	
> .99	
	1.92	
52
1.04
< 10	
0.20		
> .93		
1.82
0.33	
39	
> .99	
	1.97	
0.77
< 10	
0.14	
38	
> .98		
2.03
0.33	
39	
> .99	 0.72
1.83
	
	
< 10	
0.14	
38	
> .98	 0.71	
1.87
0.37	44	
	1.98	
> .98	 0.87
< 10	
0.16	 43			
2.02
0.36	43	 	
	1.84	
> .99
0.78
< 10	
0.15	 42			
1.88
0.49	59	
	2.00	
> .95	 1.18
< 10	
0.21	 58			
2.03
0.37	
44	
> .99	
2.02
0.89	
	
< 10	
0.16	
43	
> .95		
2.07
0.43	
51	
> .98	
1.94
0.99	
	
< 10	
0.19	
50	
> .95		
1.98
0.43	
	
> .98	
51
1.00	
1.96	
< 10	
0.20		
> .90

1 Consult lamp manufacturers for applications with Ballast Factor > 1.20

PAGE 1-­26

-A
-N
-N
-A
-N
-A
-N
-A
-A
-B
-B
-A

60/16	

46	

-E

60/16	

3	

-A

60/16	

3	

-A

60/16	

3	

-N

60/16	

3	

-A

60/16	

3	

-N

60/16	

3	

-A

60/16	

6	

-A

60/16	

6	

-A

60/16	

6	

-A

See page 1-31 for Dimensions
and Wiring Diagrams
FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS
FOR (3) & (4)
F32T8ES (25 WATT) LAMPS
Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	

25 WATT

• 3-4 Lamp Applications

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.31	37	
> .99	
	1.91	
0.71
<10	
0.14	
35	
> .96		 2.03
0.36	43	 	
	2.04	
> .90
0.88
<10	
0.16	
41			
2.14
0.51	59	 	
	2.01	
> .98
1.18
<10	
0.22	 58			
2.02
0.35	42	
> .99	
	2.07	
0.87
<10	
0.16	 41	 > .95		 2.13
0.42	50	 	
	2.07	
> .90
1.04
<10	
0.18	
48			
2.15
0.57	
	
	
	
	
68
> .98
1.30
1.91
<10	
0.25				
0.26	
	
88
0.19		
0.48	
58	
0.21	
57	
0.56	
66	
0.24	
65	
0.57	
69	
0.26	
68	
0.50	
60	
0.22	
58	
0.60	
72	
0.26	
71	
0.61	
73	
0.27	
72	

> .97	
	
	
1.11
1.26
< 10	
> .90		
> .99	
	1.33	
0.77
< 10	
> .97		
1.35
> .98	
	1.32	
0.87
< 10	
> .95		
1.34
> .99	
	1.30	
0.90
< 10	
> .95		
1.32
> .99	
	1.43	
0.86
< 10	
> .94		
1.48
> .99	
	1.33	
0.96
< 10	
> .95		
1.35
> .98	
	1.33	
0.97
< 10	
> .95		
1.35

60/16	30	 -B
60/16	30	 -B
60/16	30	 -A
60/16	30	 -A
60/16	30	 -A
60/16	30	 -A
60/16	

46	

-E

60/16	

6	

-A

60/16	

6	

-A

60/16	

6	

-A

60/16	

7a	

-A

60/16	

7a	

-A

60/16	

7a	

-A

See page 1-31 for Dimensions
and Wiring Diagrams

PAGE 1-­27

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

F32T8ES (25W) - Two Lamp Applications
	120	
		
B232PUNVEL-B	
	 		
277		
	120	
		
B232PUNVHE-B	
	 		
277		
	120	
		
B232PUNVHEH-A	
	
	 277		
2	 PAR-PS
	120	
		
B332PUNVEL-A	
			
277		
	120	
		
B332PUNVHE-A	
	 		
277		
	120	
		
B332PUNVHEH-A1	
			
277		
F32T8ES (25W) - Three Lamp Applications
	
	347	
3	SER-IS
B332IHRVHB-E	
			
480		
			
120	
B332IUNVEL-A	
			
277		
			
120	
B332IUNVHE-A	
			
277		
	3	 PAR-IS	 120	
B332IUNVHP-A 	
			
277		
	
	
	120	
B432IUNVEL-A	
			
277		
	
	
	120	
B432IUNVHE-A	
			
277		
			
120	
B432IUNVHP-A 	
			
277		

F32T8ES

• High Performance
Models and Low Profile
Designs

F32T8ES

• High Performance
Models and Low Profile
Designs

25 WATT

• 1-2 Lamp Applications

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	

Fluorescent-Electronic

TRIAD® ELECTRONIC BALLASTS

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.

F32T8ES (25W) - Three Lamp Applications
	120	
		
B332PUNVEL-A	
			
277		
	120	
		
B332PUNVHE-A	
	 	
	 277		
3 PAR-PS
	120	
		
B332PUNVHEH-A	
	 		
277			
	120	
		
B432PUNVEL-A	
	 		
277			
	120	
		
B432PUNVHE-A	
	 		
277		
	120	
		
B432PUNVHEH-E	
	 		
277		
F32T8ES (25W) - Four Lamp Applications
	120	
		
B432IUNVEL-A	
	
	
277		
		
	
	120	
B432IUNVHE-A	
	
	 277		
4	PAR-IS
			
120	
B432IUNVHP-A 	
			
277		
	120	
		
B432PUNVEL-A	
	
	 277		
4 	 PAR-PS
	120	
	
B432PUNVHE-A	
	 		
277		
	
	120	
	
B432PUNVHEH-E	
	 		
277		
	

IS = Instant Start
PS = Programmed Start

RS = Rapid Start
PAR-IS = Parallel Instant Start

FOR (1) & (2)
F32T8ES (25 WATT) LAMPS

0.46	55	
> .99	
	1.30	
0.71
<10	
0.20	 54	 > .97		 1.32
0.55	66	 	
	1.34	
> .90
0.88
<10	
0.24	 65			
1.35
0.75	90	 	
	1.28	
> .98
1.15
<10	
0.32	
88			
1.31
0.52	62	
> .99	
	1.23	
0.77
<10	
0.23	
61	
> .96		
1.26
0.59	71	 	
	
	
> .90
0.95
1.35
<10	
0.26	
70			
0.76	90	
> .99	
	1.26	
1.13
<10	
0.35	
92	
> .95		 1.23

60/16	49	 -A
60/16	49	 -A
60/16	49	 -A
60/16	49	 -A
60/16	49	 -A
60/16	49	 -E

0.62	
75	
> .99	
	1.09	
0.82
<10	60/16	 7a	 -A
0.27	
73	
> .95		
1.12
0.73	
87	
> .99	
	1.00	
0.87
<10	60/16	 7a	 -A
0.31	
85	
> .98		
1.02
0.74	
90	
> .98	
	0.99	 	
0.89
< 10 60/16	7a	 -A
0.33	
88	
> .95		
1.01
0.61	
73	
> .99	
	0.97	
0.71
<10	60/16	 50	 -A
0.27	
72	
> .97		
0.98
0.71	85	 	
	
1.02	
> .90
0.87
<10	 60/16	50	 -A
0.31	
84			
1.03
1.04	
124	 > .99	
	
0.96	
1.18
<10	 60/16	50	 -E
0.45	
118	 > .95		
1.00

See page 1-31 for Dimensions
and Wiring Diagrams
STARTING METHOD LEGEND

PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start

PAGE 1-­28

PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start

SER-IS = Series Instant Start

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS
FOR (1) & (2) F28T8 LAMPS

• High Performance
Models and Low Profile
Designs

F28T8

• Instant and Programmed
Rapid Starting Options
• 1-2 Lamp Applications
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.20	
	
> .98	
21
0.77	
3.67	
< 10	
0.10		
> .95
0.20	
	
	
24
> .99
0.87	
3.63	
< 10	
0.10		
0.22	
	
	
26
> .98
0.88	
3.38	
< 10	
0.10			
0.09	
32	
> .98	 1.04	
3.25	
< 10	
0.22	26	
3.65
> .95	 0.95	
	
< 10	
0.10	 27			
3.52
0.23	27
3.30
	
> .95	 0.88	
	
< 10	
0.10	 26			
3.31
0.24	
29	
> .95	 1.10	
3.79	
< 10	
0.11	
0.33	40	
	3.45	
> .95	 1.38
< 10	
0.15	 39			
3.54
0.25	
30	
> .99	 0.99	
3.36	
< 10	
0.11	
29	
> .98	 1.00	
3.40
0.28	
	
	
	
27
> .99	 0.88
3.26
< 10	
0.11
0.21	
25	
> .99	
	3.33	
0.83
<10	
0.11	
24	
> .92		
3.46
0.25	30	 	
	3.41	
> .90
1.01
<10	
0.12	
29			
3.45
0.35	
	
	
	3.47	
39
> .97
1.35
<10	
0.15				
3.44
0.19	
	
> .97	
65
1.22	
1.88	
< 10	
0.15		
> .90
0.14	
50	
> .98	 0.88	
1.76	
< 10	
0.47	
56	
> .99	
	1.79	
1.04
< 10	
0.21	
55	
> .94		
1.82
0.36	
43	
> .95	 0.77	
1.79	
< 10	
0.15
0.36	43	
0.75	
	
> .95	
1.76
< 10	
0.15	 42		 0.74	
0.40	49	
	1.78	
> .95	 0.87
< 10	
0.18	 48			
1.81
0.40	48	 	
	1.76	
> .99
0.83
< 10	
0.17	 46			
1.78
0.53	64	
	1.84	
> .95	 1.18
< 10	
0.23	 62			
1.90
0.41	
49	
> .99	
	1.82	
0.89
< 10	
0.18	
48	
> .95		
1.85
0.45	
54	
> .99	
	1.83	
0.99
< 10	
0.19	
53	
> .97		
1.87
0.46	
55	
> .99	
	1.80	
0.99
< 10	
0.21	
54	
> .90		
1.83

1 Consult lamp manufacturers for applications with Ballast Factors > 1.20
2 Consult Universal for availability

PAGE 1-­29

60/16	

1	

-A

60/16	

1	

-N

60/16	

1	

-N

60/16	

3a	

60/16	

3a	

-A

-A

60/16	

3a	

-N

60/16	

3a	

-A

60/16	

3a	

-A

60/16	

3a	

-N

60/16	

2	

-A

60/16	30	 -B
60/16	30	 -B
60/16	30	 -A
60/16	

46	

-E

60/16	

3	

-A

60/16	

3	

-A

60/16	

3	

-A

60/16	

3	

-N

60/16	

3	

-A

60/16	

3	

-N

60/16	

3	

-A

60/16	

6	

-A

60/16	

6	

-A

60/16	

6	

-A

See page 1-31 for Dimensions
and Wiring Diagrams

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
F28T8 - One Lamp Applications
			
120	
B132IUNVEL-A	
			
277		
	
	120	
1	IS
B132IUNVHE-N	
			
277		
			
120	
B132IUNVHP-N	
			
277		
			
347	 B232I347HP-A	
			
120	
B232IUNVEL-A2	
			
277		
			
120	
B232IUNVEL-N	
			
277		
			
120	
B232IUNVHE-A	
			
277		
			
120	
B232IUNVHEH-A1	
			
277		
			
120	
B232IUNVHP-N	
			
277		
	120	
		
B132PUNVHP-A	
	
	
277		
	
	120	
		
B232PUNVEL-B	
	 	
	
277		
1
PS
	120	
	
B232PUNVHE-B	
	 			
277		
	120	
	
B232PUNVHEH-A1	
	 			
277		
F28T8 - Two Lamp Applications
	
	347	
2	SER-IS
B332IHRVHB-E1	
			
480		
			
347	 B232I347HP-A	
			
120	
B232IUNV104-A	
			
277		
			
120	
B232IUNVEL-A2	
			
277		
			
120	
B232IUNVEL-N	
	
	 277		
2	PAR-IS
			
120	
B232IUNVHE-A	
	
	
277		
	
			
120	
B232IUNVHP-N	
			
277		
			
120	
B232IUNVHEH-A	
			
277		
			
120	
B332IUNVEL-A	
			
277		
	
	120	
	
B332IUNVHE-A	
			
277		
			
120	
B332IUNVHP-A	
			
277		

F28T8

• High Performance
Models and Low Profile
Designs
• Instant and Programmed
Rapid Starting Options

TRIAD® ELECTRONIC BALLASTS
FOR (2)(cont.), (3) & (4) F28T8 LAMPS

Fluorescent-Electronic

• 2-4 Lamp Applications
Lamp				
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
	
		 Starting	 Line	
Catalog	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
Qty.	 Method	 Volts	
Number	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
F28T8 - Two Lamp Applications
	120	
0.33	40	
> .99	
1.79	
	 	
B232PUNVEL-B	
0.71	
<10	 60/16	30	 -B
	 		
277		
0.15	
39	
> .96		 1.84
	120	
0.39	46	 	
1.90	
		
B232PUNVHE-B	
> .90
0.88	
<10	 60/16	30	 -B
	 		
277		
0.17	
45			
1.95
	120	
0.56	64	 	
1.85	
		
B232PUNVHEH-A	
> .99
1.18	
<10	 60/16	30	 -A
	
	 277		
0.24	 63			
1.86
2	PAR-PS
	120	
0.45	54	 	
1.93	
		
B332PUNVHE-A	
> .90
1.04	
<10	 60/16	30	 -A
	 		
277		
0.20	
53			
1.97
	120	
0.38	46	
>
.99	
1.91	
		
B332PUNVEL-A	
0.87	
<10	 60/16	30	 -A
	 		
277		
0.17	
45	
> .96		 1.92
	120	
0.60	72	
	
1.81	
		
B332PUNHEH-A1	
> .98
1.30	
<10	 60/16	30	 -A
	 		
277		
0.26	
71			
1.83
F28T8 - Three Lamp Applications
	
	347	
0.28	
	
> .97	
	
	
3	SER-IS
B332IHRVHB-E	
94
1.18
1.26
< 10	 60/16	
46	
-E
			
480		
0.21		
> .90		
			
120	
0.53	
66	
> .99	
	1.17	
B332IUNVEL-A	
0.77
< 10	 60/16	
6	
-A
	 	
	
277		
0.23	
65	
> .97		
1.18
			
120	
0.60	
75	
> .99	
	1.16	
B332IUNVHE-A	
0.87
< 10	 60/16	
6	
-A
			
277		
0.26	
73	
> .98		
1.19
			
120	
0.61	
73	
> .99	
	1.22	
B332IUNVHP-A	
0.89
< 10	 60/16	
6	
-A
			
277		
0.27	
71	
> .95		
1.25			
	 3	 PAR-IS	 347	 B432I347HP	
0.23	
78	
> .98	 0.99	
1.27	
< 10	 60/16	
7a	
ST
			
120	
0.57	
69	
> .99	
	1.25	
B432IUNVEL-A	
0.86
< 10	 60/16	
7a	
-A
			
277		
0.26	
68	
> .95		
1.26
			
120	
0.64	
77	
> .99	
	1.25	
B432IUNVHE-A	
0.96
< 10	 60/16	
7a	
-A
			
277		
0.28	
75	
> .98		
1.28
			
120	
0.66	
79	
> .98	 0.97	
1.23	
B432IUNVHP-A	
< 10	 60/16	
7a	
-A
			
277		
0.29	
77	
> .95	 0.97	
1.26
	120	
0.49	
59	
> .99	
1.21	
	 	
B332PUNVEL-A	
0.71	
<10	 60/16	49	 -A
	 		
277		
0.21	
58	
> .97		
1.22
	120	
0.59	71	 	
1.25	
		
B332PUNVHE-A	
> .90
0.88	
<10	 60/16	49	 -A
	 		
277		
0.25	
68			
1.29
	120	
0.79	94	 	
1.22	
		
B332PUNVHEH-A	
> .98
1.15	
<10	 60/16	49	 -A
	 	
	 277		
0.34	 92			
1.25
3 PAR-PS
0.56	
67	
> .99	
1.15	
	 		 120	 B432PUNVEL-A	
0.77	
<10	 60/16	49	 -A
			
277				
0.25	
66	
> .97		
1.17
	120	
0.64	77	 	
1.24	
		
B432PUNVHE-A	
> .90
0.95	
<10	 60/16	49	 -A
	 		
277		
0.28	
76			
1.25
	120	
0.76	
	
> .99	
	
		
B432PUNVHEH-E	
90
1.13	1.25
<10	 60/16	49	 -E
	 		
277		
0.34		
> .96		
1 Consult lamp manufacturers for applications with Ballast Factors > 1.20

See page 1-31 for Dimensions
and Wiring Diagrams

PAGE 1-­30

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS

F28T8

FOR F32T8ES AND F28T8 LAMPS

	 Overall Dimensions	
	Draw #	
L	
	ST	
	-A	
	-B	
	-E	
	-N	

9.50”	
9.50”	
9.50”	
16.88”	
9.50”	

W	

2.40”	
1.70”	
1.50”	
1.74”	
1.30”	

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.28	
95	
> .98	 0.88	
0.93	
< 10	
0.70	
85	
> .99	
	0.91	
0.77
< 10	
0.31	
84	
> .98		
0.92
0.77	
97	
> .99	
	0.90	
0.87
< 10	
0.33	
94	
> .98		
0.93
0.80	
96	
> .98	 0.89	
0.93	
< 10	
0.35	
93	
> .95	 0.88	
0.95
0.64	77	
> .99	
0.92	
0.71	
<10	
0.28	
76	
> .97		 0.93
0.77	92	 	
0.94	
> .90
0.87	
<10	
0.33	 90			
0.97
1.05	
	 > .99	
0.95	
125
1.18	
<10	
0.46		
> .98		
0.94

60/16	

7a	

ST

60/16	

7a	

-A

60/16	

7a	

-A

60/16	

7a	

-A

60/16	50	 -A
60/16	50	 -A
60/16	50	 -E

Mounting Dimensions
H	
M	
X

1.55”	
1.18”	
1.00”	
1.18”	
1.00”	

8.89”	
8.89”	
8.89”	
16.28”	
8.89”	

1.69”
1.69”
1.69”
--1.69”

-A, -B, -E, -N

ST

WIRING DIAGRAMS

DIAGRAM 1

Line

Black
White

BALLAST

DIAGRAM 2

DIAGRAM 3

DIAGRAM 3a

Blue
Blue
Blue
Red

LAMP
LAMP
LAMP

For Two Lamp operation,
Insulate one blue lead to 600V

DIAGRAM 6

DIAGRAM 46

For three lamp operation, cap any
blue lead, insulate to 600V

For Three Lamp Application, Individually
cap brown leads, Insulate to 600V

For one lamp operation, cap any
blue lead, insulate to 600V

DIAGRAM 8

DIAGRAM 30

DIAGRAM 7a

DIAGRAM 49
DIAGRAM
49

DIAGRAM 5050
DIAGRAM

PAGE 1-­31

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
F28T8 - Four Lamp Applications
			
347	 B432I347HP	
			
120	
B432IUNVEL-A	
			
277				
	4	 PAR-IS	 120	
B432IUNVHE-A	
			
277				
			
120	
B432IUNVHP-A	
			
277				
	 4	PAR-PS	120	B432PUNVEL-A	
	 		
277				
	120	
		
B432PUNVHE-A	
			
277				
	120	
		
B432PUNVHEH-E	
			
277				

F40T8

• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options

TRIAD® ELECTRONIC BALLASTS
FOR (1), (2), AND (3) F40T8 LAMPS

Fluorescent-Electronic

• 1-3 Lamp Applications
Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
F40T8 - One Lamp Applications
			
120	
B132IUNVEL-A	
			
277				
			
120	
B132IUNVHE-N	
			
277				
	 		
120	
B132IUNVHP-N	
	
		277				
	 		
347	 B232I347HP-A	
	 1	
IS	
347	 B232I347HPL	
	 		
120	
B232IUNVHP-N	
	 		
277				
			
347	 B232I347RH-A	
			
120	
B232IUNV-C	
	 		
277				
120	
	
	
B232PUNVEL-B	
	
	
277				
1		
PS
	120	
		
B232PUNVHE-B	
			
277				
F40T8 - Two Lamp Applications
	 		
347	 B259I347HP	
		
	
347	 B332I347HPL	
			
120	
B332IUNVEL-A	
	 2	 PAR-IS	 277		
			
120	
B332IUNVHE-A	
			
277		
	 		 120	
B332IUNVHP-A	
			
277		
	 		120	
B332PUNVEL-A	
	
	 277		
2	PAR-PS
		120	
	
B332PUNVHE-A 	
			
277				

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.25	
	
> .98	
32
0.76	
2.38	
< 10	 0/-18	
1	
-A
0.13		
> .95
0.30	
	
	
35
> .99
0.86	
2.46	
< 10	 0/-18	
1	
-N
0.14		
0.31	37	 	
2.32
> .99
0.86	
	
< 10	 32/0	
1	
-N
0.13	
36			 2.39				
0.13	
45	
> .98	 1.02	
2.27	
<10	 0/-18	
3a	
-A	
0.11	
38	
> .98	 0.86	
2.26	
< 10	 0/-18	
3a	
ST
0.36	44	 	
	2.34	
> .99
1.03
< 10	 32/0	
3a	
-N
0.16	
43			
2.40			
		
0.13	
45	
> .98	 1.02	
2.27	
< 20	 0/-18	
3a	
-A
0.37	43	
2.30
> .98	 0.99	
	
< 10	 0/-18	
22	
-C
0.16	
42	
	
	
2.36	
0.28	
34	
> .99	
2.38	
0.80	
<10	-20/-29	 30	 -B
0.13	
32	
> .95		
2.52
0.34	41	 	
2.43	
> .90
0.99	
<10	-20/-29	 30	 -B
0.15	 40			
2.48
0.22	
76	
> .98	 0.91	
1.20	
< 10	 0/-18	
14	
0.20	
69	
> .99	 0.82	
1.18	
< 10	 0/-18	
6	
0.57	
68	
> .99	
	1.31	
0.89
< 10	 0/-18	
6	
0.25	
66	
> .98		
1.35
0.64	
77	
> .99	
	1.29	
0.99
< 10	 0/-18	
6	
0.27	
75	
> .98		
1.32	
0.65	
78	
> .99	
	1.22	
0.95
< 10	 0/-18	
6	
0.29	
77	
> .95		
1.23			
0.53	
64	
> .99	
1.34	
0.85	
<10	-20/-29	 30	
0.23	
62	
> .97		
1.36
0.64	77	 	
1.33	
> .90
1.02	
<10	-20/-29	 30	
0.27	 74			
1.38

ST
ST
-A
-A
-A
-A
-A

See page 1-33 for Dimensions
and Wiring Diagrams

PAGE 1-­32

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS

F40T8

FOR F40T8 LAMPS

	 Overall Dimensions	
	Draw #	
L	
	ST	
	-A	
	-B	
	-C	

9.50”	
9.50”	
9.50”	
14.25”	

W	

2.40”	
1.70”	
1.50”	
1.18”	

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.29	
100	 > .99	 0.81	
0.81	
< 10	 0/-18	
7	
0.81	
97	
> .99	
	0.89	
0.86
< 10	 0/-18	
7a	
0.35	
94	
> .98		
0.91
0.93	
111	 > .99	
	0.86	
0.96
< 10	 0/-18	
7a	
0.39	
107	 > .98		
0.90
0.95	
114	 > .99		
0.81
0.92
< 10	 0/-18	
7a	
0.41	
109	 > .98
0.84
	
	
	
0.79	
95	
> .99	
0.74	
0.70	
<10	-20/-29	 49	
0.34	
92	
> .98		
0.76
0.93	111	 	
0.84	
> .90
0.93	
<10	-20/-29	 49	
0.40	 109			
0.85

ST
-A
-A
-A
-A
	

-A

Fluorescent-Electronic

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
		
F40T8 - Three Lamp Applications
	
347	 B432I347HPL	
	
	
			
120	
B432IUNVEL-A	
	 	
	 277		
3 PAR-IS
	
	120	
	
B432IUNVHE-A	
			
277		
	
120		
	
	
B432IUNVHP-A
			
277	
	
	120	
		
B432PUNVEL-A	
	
	 277		
3	PAR-PS
	120	
		
B432PUNVHE-A	
			
277				
Mounting Dimensions
H	
M	
X

1.55”	
1.18”	
1.00”	
1.00”	

8.89”	 1.69”
8.89”	 1.69”
8.89”	 0.88”
13.75”	 ---

-A, -B

ST

-C

WIRING DIAGRAMS

Line

Black
White

BALLAST

Blue
Blue
Blue
Red

LAMP
LAMP
LAMP

For Two Lamp Operation,
Insulate one blue lead to 600V

DIAGRAM 1

Line

Black
White
Yellow
Yellow

DIAGRAM 2

DIAGRAM 3a

DIAGRAM 6

Blue

BALLAST

Blue
Red
Red

LAMP
LAMP
LAMP
LAMP

For Three Lamp Operation,
Insulate one blue lead to 600V

For three lamp operation, cap any
blue lead, insulate to 600V

DIAGRAM 7

DIAGRAM 7a

For one lamp operation, cap any
blue lead, insulate to 600V

DIAGRAM 14

DIAGRAM 30

DIAGRAM 22

DIAGRAM 49
DIAGRAM
49

PAGE 1-­33

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

T8

• Instant Starting Options

SLIMLINE

Slimline Lamps

• 1-2 Lamp Applications
• 8’ T8 SLIMLINE

Fluorescent-Electronic

• High Performance
Models

TRIAD® ELECTRONIC BALLASTS
FOR (1) AND (2)
F48T8, F72T8, F96T8 AND F96T8ES LAMPS

Lamp				
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
	
		 Starting	 Line	
Catalog	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
Qty.	 Method	 Volts	
Number	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
F48T8 - One Lamp Applications
	
	
120	 B244	I120HE	
0.30	
35	
> .95	 1.04	
2.97	
	0/-18	 14	 ST
1	IS
< 10
		
	
277	 B244	I277HE-A	
0.14	
36	
> .90	 1.06	
2.94		
0/-18	
14	
-A
F48T8 - Two Lamp Applications
	
	 120	 B244	I120HE	
0.47	
55		
0.90	
1.64	
	0/-18	 14	 ST
> .95
2	PAR-IS
< 10
		
	
277	 B244	I277HE-A	
0.21	
56	
	0.89	 1.59		 0/-18	 14	 -A
F72T8 - One Lamp Applications
	
	
120	 B244	I120HE	
0.42	
50		
1.03	
2.06	
	0/-18	 14	 ST
> .95
1	IS
< 10
		
	
277	 B244	I277HE-A	
0.19	
52	
	1.04	 2.00		 0/-18	 14	 -A
F72T8 - Two Lamp Applications
	
	 120	 B244	I120HE	
0.70			
0.88	
1.07	
	0/-18	 14	 ST
82
> .95
2	PAR-IS
< 10
		
	
277	 B244	I277HE-A	
0.30	
	
	0.87	 1.06		 0/-18	 14	 -A
F96T8 - One Lamp Applications
	
	
120	
0.54	
	
> .99	
	
	
	
	
	
	
B259IUNVEL-A	
64
0.99
1.55
< 10
32/0
15
-A
		
	
277			
0.24		
> .97						
			
120	
	
0.60	
72	
> .99	
	1.50	
B259IUNVHP-A
1.08
< 10	 32/0	
14	
-A
	 1	
IS	
277	 		
0.26	
71	
> .98	
	
1.52	
	
	
		
	
	
120	
0.60	
71	
> .99	
	1.52	 	
	
	
	
B259IUNVHE-A	
1.08
< 10
32/0
15
-A
		
	
277			
0.26	
70	
> .97		
1.54				
	
	
120		
	
0.93	
111	 > .99	
	0.79	 	
	
	
-A
	
B259IUNVEL-A
.88
< 10
32/0
15
		
	
277			
0.39	
108	 > .98		
0.81				
			
347	 B259I347HP	
0.20	
68	
> .97	 1.05	
1.54	
< 10	 32/0	
14	
ST
F96T8 - Two Lamp Applications
	
	
120		
	
0.84	
101	 > .99	
	0.77	 	
	
	
-A
	
B259IUNVEL-A
.78
< 10
32/0
15
		
	
277			
0.36	
99	
> .98		
0.79				
	
	
120		
	
0.92	
108	 > .99	
	0.81	 	
	
	
-A
	
B259IUNVHE-A
.88
< 10 60/16
15
		
	
277			
0.39	
107	 > .99		
0.82				
	
	120	
	
0.95	
113	 > .99	
	0.78	
2	PAR-IS
B259IUNVHP-A
0.88
< 10	 32/0	
14	
-A
			
277	 		
0.40	
110	 > .98	
	
0.80	
	
	
		
	 		
347	 B259I347HP	
0.33	
113	 > .99	 0.89	
0.79	
< 10	 32/0	
14	
ST
F96T8ES (57W) - One Lamp Applications
	
	
120	
	
0.56	
67	
> .99	
	1.61	 	
1	IS
B259IUNVHE-A
1.08
< 10 60/16	15	 -A
		
	
277			
0.26	
66	
> .97		
1.64		
	
	
120	
	0.51	 	
> .99	
	
	
	
	
B259IUNVEL-A
61
0.99
1.62
< 10 60/16	15	 -A
		
	
277			
0.23		
> .97				
F96T8ES (57W) - Two Lamp Applications
	
	
120	
	
0.92	
108	 > .99	
	0.81	 	
	
B259IUNVHE-A
0.88
< 10 60/16	15	 -A
	
	
277			
0.39	
107	 > .99		
0.82		
2	PAR-IS
	
	
120	
	
0.80	
95	
> .99	
	0.82	 	
	
B259IUNVEL-A
0.78
< 10 60/16	15	 -A
		
	
277			
0.34	
93	
> .98		
0.84		
F96T8ES (54W) - One Lamp Applications
	
	
120	
	
0.51	
61	
> .99	
	1.77	 	
1	IS
B259IUNVHE-A
1.08
< 10 60/16	15	 -A
		
	
277			
0.23	
60	
> .96		
1.80	F96T8ES (54W) - Two Lamp Appl
F96T8ES (54W) - Two Lamp Applications
	
	 120	
	
0.80	
95	
> .99	
	0.93	 	
2	PAR-IS
B259IUNVHE-A
0.88
< 10 60/16	15	 -A
		
	
277			
0.34	
93	
> .98		
0.95		
F96T8ES (49W) - One Lamp Applications
	
	
120	
	
0.41	
48	
> .99	
	2.06	 	
1	IS
B259IUNVEL-A
0.99
< 10 60/16	15	 -A
		
	
277			
0.19	
49	
> .96		
2.02	F96T8ES (54W) - Two Lamp Appl
F96T8ES (49W) - Two Lamp Applications
	
	 120	
	
0.64	
77	
> .99	
	1.01	 	
2	PAR-IS
B259IUNVEL-A
0.78
< 10 60/16	15	 -A
		
	
277			
0.28	
76	
> .98		
1.03		
IS = Instant Start
PS = Programmed Start

RS = Rapid Start
PAR-IS = Parallel Instant Start

STARTING METHOD LEGEND

PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start

PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start

SER-IS = Series Instant Start

See page 1-33 for Dimensions
and Wiring Diagrams

PAGE 1-­34

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS
FOR (1) AND (2)
F48T8HO, F60T8HO, F72T8HO AND
F96T8HO LAMPS

IS = Instant Start
PS = Programmed Start

	 Overall Dimensions	
	Draw #	
L	
	SL	
	-S	

11.75”	
11.75”	

RS = Rapid Start
PAR-IS = Parallel Instant Start

W	

• 1-2 Lamp Applications
High Output Lamps

• 4-8’ T8 High Output

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.75
> .98
< 10
	93	 	0.98	 1.05	
	-20/-29	 4a	
0.34		
> .95			
< 12

-S

0.41
> .96
< 10
	49	 	1.01	 2.06	
	-20/-29	 4	
0.19		
> .92			
< 15

-S

0.80
> .98
< 10
	96	 	1.00	 1.04	
	-20/-29	 4a	
0.36		
> .95			
< 12

-S

1.57
	
0.67	

-S

187
	
184	

> .98
	0.95	
> .96		

STARTING METHOD LEGEND

PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start

0.51
	
0.52	

< 10	 -20/-29	

PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start

4	

SER-IS = Series Instant Start

Mounting Dimensions
H	
M	
X

3.13”	 1.78”	 11.14”	 2.00”
1.70”	 1.18”	 11.19”	 1.05”

WIRING DIAGRAMS

For One Lamp Operation,
Insulate one blue lead to 600V

Yellow leads must be connected
to plunger end of fixture

For One Lamp Applications, individually
cap yellow leads, Insulate fo 600V

DIAGRAM 3

DIAGRAM 4

DIAGRAM 4a

PAGE 1-­35

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
F48T8HO - One Lamp Applications
	
	120	
1	PS
B286PUNVHE-S	
	 		
277			
F48T8HO - Two Lamp Applications
	
	120	
2	SER-PS
B286PUNVHE-S	
	 		
277			
F96T8HO - One Lamp Applications
	
	120	
1	PS
B286PUNVHE-S	
	 		
277			
F96T8HO - Two Lamp Applications
	
	120	
2	SER-PS
B286PUNVHE-S	
	 		
277			

T8HO

• Instant Starting Options

• Multiple Lamp Operation
• Rapid and Programmed Starting Options
• T5 Ballasts meet ANSI requirement for
end-of-lamp life safety shutdown
• Super Low Profile Designs
• 1-2 Lamp Applications

Fluorescent-Electronic

T5

TRIAD® T5 ELECTRONIC
BALLASTS
FOR F8, F13, F14, F21 AND F24 LAMPS

Lamp				
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
	
		 Starting	 Line	
Catalog	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
Qty.	 Method	 Volts	
Number	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
F14T5 - One Lamp Applications
			
120	
	
0.12	
	
> .99	
	
	
< 10
B114PUNV70-D
14	
0.70
5.00
	
	
277			
0.06	
> .90			
< 15	50/10	 43	 -D
	
	
	120	
	
0.14	
	
> .98	
	
	
B228PUNV-C
17	
1.05
6.17
< 10	 0/-18	
40	
-C
	 1	PS	
277			
0.07	
> .90			
	
	
	
120	
	
0.15	
	
> .98	
	
	
B228PUNV-N
17	
1.02
6.17
< 10	 0/-18	
40	
-N
	 	
	
277			
0.07	
> .90			
	
	
	120	
	
0.14	
16	
> .98	
	
5.56	
< 15
B228PUNV90-C
0.89
	 	
	
277			
0.07	
17	
> .85		
5.24	
< 20	0/-18	 37	 -C
	
	
	120	
	
0.14	
16	
> .98	
	6.00	
B228PUNV95-D
0.96
< 10	 0/-18	
40	
-D
	 	
	
277			
0.07	
17	
> .85		
5.65	
	
F14T5 - Two Lamp Applications
	
	120	
	
0.28	
	
> .98	
	
B228PUNV-C
32	
1.00	
3.12	
< 10	 0/-18	
37	
-C
			
277			
0.12	
> .95
	120	
	0.27		
> .98	
		
B228PUNV-N
33	
1.01	
3.06	
< 10	 0/-18	
37	
-N
			
277			
0.12	
> .95
	
	120	
	
0.24	
	
> .99	
B228PUNV85-D
29	
0.88	
3.03	
< 10	 0/-18	
30	
-D
	 	
	 277			
0.11	
> .97			
	 2	SER-PS
	120	
	
0.24	
	
> .99	
< 10
	
B228PUNV90-C
29	
0.89	3.07	
			
277			
0.11	
> .90			
< 15	0/-18	 37	 -C
	
	120	
	
0.26	
31	
> .99	
3.06
	
B228PUNV95-D
0.95	
< 10	 0/-18	
37	
-D
			
277			
0.12	
32 	 > .95		
2.97	
			
120	
	
0.31	
37	
> .99	
3.12
B228PUNV115-D
1.15	
< 10	 0/-18	
37	
-D
			
277			
0.13	
36 	 > .98		
3.19	
F21T5 - One Lamp Applications
	
	120	
0.13	
15	
> .99	
3.33	
	
< 10 50/10	43	 -D
	 	
	
277	 B128PUNV50-D	
		
0.07	
16 	 > .86	 0.50	
	
3.13		
	
	
	120	
	
0.14	
	
> .99	
	
	
20	
< 10 50/10	43	 -D
	 	
	
277	 B128PUNV60-D
		
0.07	
> .88	 0.60	3.00
	
		
	 	
	120	
	
0.18	
21	
> .99	
3.33	
	
< 10 50/10	43	 -D
	 	
	
277	 B128PUNV70-D
		
0.08	
22	
> .90	 0.70	
	
3.18		
	
	
	120	
	
0.20	
	
> .98	
	
	
24	
< 10 0/-18	40	 -C
	 	
	
277	 B228PUNV-C
		
0.09	
> .95	 1.03	4.29
	
		
	
120	
	
0.20	
	
> .98	
	
	
	1	
PS	
24	
< 10 0/-18	40	 -N
	
	
277	 B228PUNV-N
		
0.10	
> .95	 1.01	4.21
	
		
	
	
	120	
	
0.19	
22	
> .99	
4.05	
< 10	
	 	
	
277	 B228PUNV90-C
		
0.09	
23 	 > .90	 0.89	
	
3.87 	
< 15	 0/-18	37	 -C
	
	
	120	
	
0.20	
	
> .99	
	
	
24	
< 10 0/-18	40	 -D
	 	
	
277	 B228PUNV95-D
		
0.09	
> .90	 0.96	4.00
	
		
	
F21T5 - Two Lamp Applications
	
	120	
	
0.41	
48	
	
	2.08	
	
> .98
1.00
< 10	 0/-18	
37	
-C
			
277	 B228PUNV-C
		
0.17	
46	
	
	
2.17
			
120	
	
0.39	
47	
	
	2.13	
> .98
1.00
< 10	 0/-18	
37	
-N
			
277	 B228PUNV-N
		
0.17	
46	
	
	
2.17
	
120	
	
0.35	
41	
> .99	
2.10
	 277			
B228PUNV85-D
0.86	
	
< 10	 0/-18	
30		
-D
			
0.15	
40	
> .98		
2.15		
	
2	SER-PS
	
	120	
	
0.35	
	
> .99	
	
	
42
2.12
< 10		 0/-18	
37		
-C
	 	
	
277	 B228PUNV90-C
		
0.16		
> .95 	 0.89
		
	
	 	
	120	
	
0.40	
	
> .99	
	
B228PUNV95-D
47	
0.95	
2.02	
< 10	 0/-18	
37	
-D
			
277			
0.17	
> .95
			
120	
	
0.44	
52	
> .99	
2.21
B228PUNV115-D
1.15	
< 10	 0/-18	
37	
-D
			
277			
0.19	
51 	 > .98		
2.25	

See page 1-41 for Dimensions and Wiring Diagrams
IS = Instant Start
PS = Programmed Start

RS = Rapid Start
PAR-IS = Parallel Instant Start

STARTING METHOD LEGEND

PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start

PAGE 1-­36

PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start

SER-IS = Series Instant Start

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® T5 ELECTRONIC
BALLASTS
FOR F28 AND F35T5 LAMPS

• Multiple Lamp Operation
• Rapid and Programmed Rapid
Starting Options
• T5 Ballasts meet ANSI requirement for
end-of-lamp life safety shutdown
• Super Low Profile Designs
• 1-2 Lamp Applications
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.17	
	
20	
0.08	
0.18	
22	
0.09	
25	
0.21	
25	
0.11	
27	
0.27	
	
32	
0.12	
0.27	
	
32	
0.12	
0.25	
30	
0.11	
29	
0.25	
29	
0.11	
30 	
0.25	
	
30
0.11		
0.55	
0.23	
0.54	
0.23	
0.48	
0.21	
0.48	
0.21	
0.51	
0.22	
0.59	
0.25	

63	
61	
65	
64	
54	
53	
58	
56	
61	
60	
69	
68	

> .99	
	
< 10	
> .90	 0.50	2.50
		
< 12	
> .99	
2.73	
	
< 10
> .92	 0.60	
	
2.40		
> .99	
2.80	
	
< 10
> .93	 0.70	
	
2.59		
> .98	
1.00	
3.12	
< 10	
> .95
> .98	
1.00	
3.12	
< 10	
> .95
> .99	
2.93
0.88	
	
< 10	
> .98		
3.00		
> .99	
3.10
< 10
> .90	 0.90	
	
3.00		
< 15	
> .99	
	
	
0.96
3.20
< 10	
> .95			
	1.59	
1.00
< 10	
	
1.64
	1.54	
> .98		
1.00
< 10	
	
1.56
> .99	
1.57
0.85	
< 10	
> .98		
1.60	
	1.55	
> .98		
0.90
< 10	
	
1.61
> .99	
	1.56	
0.95
< 10	
> .98		
1.58
> .99	
	1.67	
1.15
< 10	
> .98		
1.69

> .98		

50/10	43	 -D
50/10	43	 -D
0/-18	

40	

-C

0/-18	

40	

-N

0/-18	
	

40		

-D

0/-18	

37	

-C

0/-18	

40	

-D

0/-18	

37	

-C

0/-18	

37	

-N

0/-18	

30	

-D

0/-18	

37	

-C

0/-18	

37	

-D

0/-18	

37	

-D

0.24	
	
29
0.11		

> .99		

	
0.96
	

< 10	

0/-18	

40	

-D

0.48	
0.21	

> .99		

	1.67	
0.95
< 10	
	
1.70

0/-18	

37	

-D

< 10	

0/-18	

40	

-N

< 10	

0/-18	

40	

-D

0/-18	

37	

-N

0/-18	

37	

-D

< 10	

50/10	

43	

-D

< 10	

0/-18	

40	

-D

< 10	

0/-18	

40	

-C

< 10	

0/-18	

40	

-N

57	
56	

0.24	
	
29
0.11		
0.23	
	
28
0.11		
0.49	
0.21	
0.47	
0.20	

59	
58	
56	
54	

0.25	
	
30
0.12		
0.32	
	
38
0.14		
0.33	
	
40
0.15		
0.33	
	
40
0.15		

> .98
	
> .95	1.00
	
	
> .99
	
> .95	0.96
	
	
> .98		
> .99		

	
3.31

50/10	43	 -D

	
3.45

	
3.43

	1.69	
1.00
< 10	
	
1.72
	1.70	
0.95
< 10	
	
1.76

> .99
	
> .95	0.70
	
	
> .99
	
> .97	0.95
	
	
> .99
	
> .97	1.00
	
	
> .99
	
> .95	1.00
	
	

	
2.33

	
2.50

	
2.50

	
2.50

See page 1-41 for Dimensions and Wiring Diagrams

PAGE 1-­37

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
F28T5 - One Lamp Applications
	
	120	
	 	
	
277	 B128PUNV50-D	
		
	
	
	120	
	
	 	
	
277	 B128PUNV60-D
		
	
	
	120	
	
	 	
	
277	 B128PUNV70-D
		
	 	
	120	
	
	 	
	
277	 B228PUNV-C
	
	
			
120	
	
	
	
277	 B228PUNV-N
	
	 	
	120	
	
	
B228PUNV85-D
			
277			
	
	120	
	
	 1	PS	
277	 B228PUNV90-C
	
	 	
	120	
	
B228PUNV95-D
	 	
	
277			
	
F28T5 - Two Lamp Applications
	
	120	
	
	
			
277	 B228PUNV-C
	
	120	
	
		
			
277	 B228PUNV-N
	
	
	120	
	
	
B228PUNV85-D
			
277			
	
	120	
	
	 	
	 277	 B228PUNV90-C
	
2	SER-PS
	
	120	
	
			
277		B228PUNV95-D	
			
120	
	
	
	
277		B228PUNV115-D	
F28T5ES (26W) - One Lamp Applications
	
	120	
	
1	PS
			
277	 B228PUNV95-D
	
F28T5ES (26W) - Two Lamp Applications
	
	120	
	
2	SER-PS
			
277	 B228PUNV95-D
	
F28T5ES (25W) - One Lamp Applications
	
	120	
	
1	PS
			
277	 B228PUNV-N
	
	
	120	
	
	
			
277	 B228PUNV95-D
	
F28T5ES (25W) - Two Lamp Applications
	
	120	
	
2	SER-PS
			
277	 B228PUNV-N
	
	
	120	
	
	
			
277	 B228PUNV95-D
	
F35T5 - One Lamp Applications
	
	120	
	
	
			
277	 B135PUNV70-D
	
	
	120	
	
	
			
277	 B228PUNV95-D
	
	
	120	
	
1	PS
			
277	 B228PUNV-C
	
	
	120	
	
	
			
277	 B228PUNV-N
	

T5

Fluorescent-Electronic

T5HO

• Multiple Lamp Operation
• Programmed Rapid and
Instant Starting Models
• T5HO Ballasts meet ANSI
requirements for end-of-lamp
life safety shutdown
• Super Low Profile Designs
• 1-4 Lamp Applications

TRIAD® T5HO ELECTRONIC
BALLASTS
FOR F24, F39 AND
F54 T5HO LAMPS

Lamp				
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
	
		 Starting	 Line	
Catalog	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
Qty.	 Method	 Volts	
Number	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
F24T5HO - One Lamp Applications
	
	120	
	0.23
> .98
1	PS
	
B224PUNV-C
	28	 	 1.06	
3.79	
< 10	 0/-18	
40	
-C
	
	
277	 		
0.10		
> .95
F24T5HO - Two Lamp Applications
	
	120	
	0.45
53
1.89
	
B224PUNV-C
	
	
> .98	 1.00	
	
< 10	 0/-18	
37	
-C
	
277		
	
0.19	
52			
1.92
2	SER-PS	
	
	120	
	0.51
> .98
	
B239PUNV-D
	59	 	 1.15	
1.95	
< 10	 0/-18	
37	
-D
	
	
277			
0.22	
	
> .95		
	
F39T5HO - One Lamp Applications
	
	120	
	0.34
41
2.32
	
B224PUNV-C
	
	
> .98	 0.95	
	
< 10	 0/-18	
40	
-C
	
	
277	 		
0.15	
40	
		
2.38
1	PS
	
	120	
	0.39
> .98
	
B239PUNV-D
	47	 	 1.10	
2.34	
< 10	 0/-18	
40	
-D
	
	
277	 		
0.18		
> .95		
	
F39T5HO - Two Lamp Applications
	
	120	
	0.75
89
1.12
2	SER-PS
B239PUNV-D
	
	
> .98	 1.00	
	
< 10	 0/-18	
37	
-D	
			
277	 	
	
0.32	
88			
1.14
F54T5HO - One Lamp Applications
			
347	 B254P347-D	
0.19	
64	
> .95	 1.02	
1.59	
< 10	 -20/-29	 37	
-D
			
347	
0.19	
	
> .98	
	
< 10	
B254PHRVHB-E	
66
1.02	1.55
-20/-29	42	 -E
			
480			
0.15		
> .90			
< 15
			
120	
0.49	
	
> .99	
B254PUNV-D	
59
1.00	
1.69	
< 10	 -20/-29	 40	
-D
	 1	
PS	
277			
0.22	
	
> .96			
			
120	
0.49	
	
> .99	
B254PUNVHB-D	
59
1.00	
1.69	
< 10	 -20/-29	 40	
-D
			
277			
0.22	
	
> .96			
	
	120	
0.50	
60	
> .99	 1.00
1.67	
	
< 10 -20/-29	A	 -A
	 	
	
277	 B254PUNVPL-A	
		
0.23	
59	
> .94	 1.02		
1.71		
	
	
	120	
0.50	
60	
> .99	 1.00
1.67	
	
	
B254PUNVPLHBA	
	
< 10 -20/-29	A	 -A
	
	
277	 		
0.23	
59	
> .94	 1.02 	
1.71
	
			
120	
0.54	
	
> .95	
< 15
B454PUNV-E	
65
1.05	1.62	 	-20/-29	 44	 -E
			
277			
0.26	
	
> .90			
< 20
			
120	
0.54	
	
> .95	
< 15
B454PUNVHB-E	
65
1.05	1.62	 	-20/-29	 44	 -E
			
277			
0.26	
	
> .90			
< 20
F54T5HO - Two Lamp Applications
			
347	
0.35	
120	 > .98	
	0.83	
B254PHRVHB-E	
1.00
< 10	 -20/-29	 41	
-E
			
480			
0.26	
119	 > .95		
0.84
			
120	
0.96	
116	 > .99
	0.86	
B254PUNV-D	
	1.00
< 10	 -20/-29	 37	
-D
			
277			
0.41	
113	 > .98	
	
0.88	
			
120	
0.96	
116	 > .99
	0.86	
B254PUNVHB-D	
	1.00
< 10	 -20/-29	 37	
-D
	 2	 SER-PS	 277			
0.41	
113	 > .98	
	
0.88	
			
347	 B254P347-D	
0.35	
120	 > .98	 1.00	
0.83	
< 10	 -20/-29	 37	
-D
			
120	
1.01	122	
	
0.82	
< 10	
B454PUNV-E	
> .95	 1.00
-20/-29	44	 -E
	
	
277			
0.44	
121			
0.83	
< 15
	
			
120	
1.01	122	
	
0.82	
< 10	
B454PUNVHB-E	
> .95	 1.00
-20/-29	44	 -E
			
277			
0.44	
121			
0.83	
< 15
	
	120	
0.94	
113	 > .99	 0.96
0.85	
	
< 10 -20/-29	A	 -A
	 	
	 277	 B254PUNVPL-A	
		
0.40	
110	 > .98	 0.99		
0.90		
2	PAR-PS
	
	120	
0.94	
113	 > .99	 0.96
0.85	
	
	
B254PUNVPLHBA	
	
< 10 -20/-29	A	 -A
	
	
277	 		
0.40	
110	 > .98	 0.99	
0.90		
	
F54T5HO - Three Lamp Applications
	
	120	
1.52	
184	 > .98	
	0.57	

	
B454PUNV-E	
1.05
< 10	 -20/-29	 44	
-E
	
	 277			
0.66	
182	 > .95		
0.58
3	SER-PS
	
	120	
1.52	
184	 > .98	
	0.57	
	
B454PUNVHB-E	
1.05
< 10	 -20/-29	 44	
-E
			
277			
0.66	
182	 > .95		
0.58	
	
	120	
1.34	
159	 > .99	
	
	
0.90	0.57
< 10 -20/-29	B	 -E
	 	
	 277	 B454PUNVPL-E	
		
0.58	
157	 > .97				
3	PAR-PS
	
	120	
1.34	
159	 > .99	
	
	
0.90	0.57
< 10 -20/-29	B	 -E
	 	
	
277	 B454PUNVPLHBE	
		
0.58	
157	 > .97				
	

See page 1-41 for Dimensions and Wiring Diagrams

PAGE 1-­38

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® T5HO ELECTRONIC
BALLASTS
FOR F24, F39 AND
F54 T5HO LAMPS
Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	

• Multiple Lamp Operation
• Programmed Rapid and Instant Starting
Models
• T5HO Ballasts meet ANSI requirements for
end-of-lamp life safety shutdown
• Super Low Profile Designs
• 1-4 Lamp Applications

T5HO

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
> .98	
	0.43	
1.00
< 10	 -20/-29	 44	
-E
> .99		
0.44	
> .98	
	0.43	

1.00
< 10	 -20/-29	 44	
-E
> .99		
0.44
> .99	
	
	
0.90	0.43
< 10 -20/-29	B	 -E
> .98				
> .99	
	
1.00
> .96		
> .99	
1.00	
> .93		
> .99	
1.00	
> .93		

	
1.82

< 10	

1.81	
	
< 10
1.83		
1.81	
	
< 10
1.83		

> .99	
	0.93	
1.00
< 10	
> .98		
0.97	
> .99	
0.92	
	
0.96	
< 10
> .97		
0.95		
> .99	
0.92	
	
0.96	
< 10
> .97		
0.95		
> .99	
0.90	
> .97		
> .99	
0.90	
> .97		

0.60	
	
< 10
0.61		
0.60	
	
< 10
0.61		

> .99	
0.90	
> .97		
> .99	
0.90	
> .97		

0.46	
	
< 10
0.47		
0.46	
	
< 10
0.47		

> .99	
> .92	
> .99	
> .92	

1.00
0.99		
1.00
0.99		

1.79	
	
< 10
1.80		
1.79	
	
< 10
1.80		

> .99	
0.96	
> .97		
> .99	
0.96	
> .97		

0.90	
	
< 10
0.93		
0.90	
	
< 10
0.93		

> .99	
0.90	
> .97		
> .99	
0.90	
> .97		

0.58	
	
< 10
0.60		
0.58	
	
< 10
0.60		

> .99	
0.90	
> .98		
> .99	
0.90	
> .98		

0.45	
	
< 10
0.46		
0.45	
	
< 10
0.46		

> .99	
1.00	
> .96		
> .99	
1.00	
> .96		
> .99	
1.00	
> .92		
> .99	
1.00	
> .92		

1.85	
	
< 10
1.89		
1.85	
	
< 10
1.89		
1.85	
	
< 10
1.89		
1.85	
	
< 10
1.89		

Page 1-­39

60/16	

40	

-D

60/16	A	 -A
60/16	A	 -A
60/16	

37	

-D

60/16	A	 -A
60/16	A	 -A
60/16	B	 -E
60/16	B	 -E
60/16	B	 -E
60/16	B	 -E
60/16	A	 -A
60/16	A	 -A
60/16	A	 -A
60/16	A	 -A
60/16	B	 -E
60/16	B	 -E
60/16	B	 -E
60/16	B	 -E
60/16	40	 -D
60/16	40	 -D
60/16	A	 -A
60/16	A	 -A

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

F54T5HO - Four Lamp Applications
	
	120	
1.96	
235	
	
B454PUNV-E	
	
	 277			
0.84	
229	
4	SER-PS
			
120	
1.96	
235	
B454PUNVHB-E	
			
277			
0.84	
229	
	
	120	
1.77	
210	
4	PAR-PS
B454PUNVPLHBE	
	
	
277	 		
0.76	
207	
	
F54T5HOES (51W) - One Lamp Applications
	
	120	
0.46	
	
	
B254PUNV-D	
55
	
	
277			
0.20		
	
	120	
0.46	
	
1	PS
	
B254PUNVPL-A	
55
	
277	 		
0.21		
	
	
	120	
0.46	
	
	
B254PUNVPLHBA	
55
	
277	 		
0.21		
	
F54T5HOES (51W) - Two Lamp Applications
	
	120	
0.89	
107	
2	SER-PS
	
B254PUNV-D	
	
	 277			
0.37	
103	
	
	120	
0.90	
104	
	 	
	 277	 B254PUNVPL-A	
		
0.39	
101	
2	PAR-PS
	
	120	
0.90	
104	
	 	
	
277	 B254PUNVPLHBA	
		
0.39	
101	
	
F54T5HOES (51W) - Three Lamp Applications
	
	120	
1.27	
151	
	 	
	 277	 B454PUNVPL-E	
		
0.55	
148	
3	PAR-PS
	
	120	
1.27	
151	
	 	
	
277	 B454PUNVPLHBE	
		
0.55	
148	
	
F54T5HOES (51W) - Four Lamp Applications
	
	120	
1.65	
196	
	 	
	 277	 B454PUNVPL-E	
		
0.71	
192	
4	PAR-PS
	
	120	
1.65	
196	
	 	
	
277	 B454PUNVPLHBE	
		
0.71	
192	
	
F54T5HOES (50W) - One Lamp Applications
	
	120	
0.47	
56	
	 	
	
277	 B254PUNVPL-A	
		
0.21	
55	
1	PS
	
	120	
0.47	
56	
	 	
	
277	 B254PUNVPLHBA	
		
0.21	
55	
	
F54T5HOES (50W) - Two Lamp Applications
	
	120	
0.92	
106	
	 	
	 277	 B254PUNVPL-A	
		
0.40	
103	
2	PAR-PS
	
	120	
0.92	
106	
	 	
	
277	 B254PUNVPLHBA	
		
0.40	
103	
	
F54T5HOES (50W) - Three Lamp Applications
	
	120	
1.30	
154	
	 	
	 277	 B454PUNVPL-E	
		
0.56	
151	
3	PAR-PS
	
	120	
1.30	
154	
	 	
	
277	 B454PUNVPLHBE	
		
0.56	
151	
	
F54T5HOES (50W) - Four Lamp Applications
	
	120	
1.67	
198	
	 	
	 277	 B454PUNVPL-E	
		
0.72	
194	
4	PAR-PS
	
	120	
1.67	
198	
	 	
	
277	 B454PUNVPLHBE	
		
0.72	
194	
	
F54T5HOES (49W) - One Lamp Applications
	
	120	
0.44	
54	
	
B254PUNV-D	
	
277	 		
0.20	
53	
	
	
	120	
0.44	
54	
	
B254PUNVHB-D	
	 1	
PS
277	 		
0.20	
53	
	
	
	120	
0.45	
54	
	
B254PUNVPL-A	
	
277	 		
0.21	
53	
	
	
	120	
0.45	
54	
	
B254PUNVPLHBA	
	
277	 		
0.21	
53	
	

• Multiple Lamp Operation
• Programmed Rapid and
Instant Starting Models
• T5HO Ballasts meet ANSI
requirements for end-of-lamp
life safety shutdown
• Super Low Profile Designs
• 1-4 Lamp Applications

T5HO

Fluorescent-Electronic

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	

TRIAD® T5HO ELECTRONIC
BALLASTS
FOR F24, F39 AND
F54 T5HO LAMPS

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.

F54T5HOES (49W) - Two Lamp Applications
	
	120	
0.87	
	 	
	 277	 B254PUNV-D	
		
0.37	
2	SER-PS
	
	120	
0.87	
	 	
	
277	 B254PUNVHB-D	
		
0.37	
	
	
	120	
0.86	
	 	
	 277	 B254PUNVPL-A	
		
0.37	
2	PAR-PS
	
	120	
0.86	
	 	
	
277	 B254PUNVPLHBA	
		
0.37	
	
F54T5HOES (49W) - Three Lamp Applications
	
	120	
1.19	
	 	
	 277	 B454PUNVPL-E	
		
0.52	
3	PAR-PS
	
	120	
1.19	
	 	
	
277	 B454PUNVPLHBE	
		
0.52	
	
F54T5HOES (49W) - Four Lamp Applications
	
	120	
1.61	
	 	
	 277	 B454PUNVPL-E	
		
0.69	
4	PAR-PS
	
	120	
1.61	
	 	
	
277	 B454PUNVPLHBE	
		
0.69	
	
F54T5HOES (47W) - One Lamp Applications
	
	120	
0.42	
	 	
	
277	 B254PUNV-D	
		
0.20	
	
	
	120	
0.45	
	 1	PS
	
277	 B254PUNVPL-A	
		
0.21	
	
	
	120	
0.45	
	 	
	
277	 B254PUNVPLHBA	
		
0.21	
	
F54T5HOES (47W) - Two Lamp Applications
	
	120	
0.85	
	 	
	
277	 B254PUNV-D	
		
0.36	
	
	
	120	
0.86	
	 	
	 277	 B254PUNVPL-A	
		
0.37	
2	PAR-PS
	
	120	
0.86	
	 	
	
277	 B254PUNVPLHBA	
		
0.37	
	
F54T5HOES (47W) - Three Lamp Applications
	
	120	
1.21	
	 	
	 277	 B454PUNVPL-E	
		
0.53	
3	PAR-PS
	
	120	
1.21	
	 	
	
277	 B454PUNVPLHBE	
		
0.53	
	
F54T5HOES (47W) - Four Lamp Applications
	
	120	
1.59	
	 	
	 277	 B454PUNVPL-E	
		
0.68	
4	PAR-PS
	
	120	
1.59	
	 	
	
277	 B454PUNVPLHBE	
		
0.68	
	

105	
102	
105	
102	
103	
101	
103	
101	

> .99	
1.00	
> .98		
> .99	
1.00	
> .98		
> .99	
0.97	
> .97		
> .99	
0.97	
> .97		

0.95	
	
< 10
0.98		
0.95	
	
< 10
0.98		
0.94	
	
< 10
0.96		
0.94	
	
< 10
0.96		

142	
140	
142	
140	

> .99	
0.90	
> .96		
> .99	
0.90	
> .96		

0.63	
	
< 10
0.64		
0.63	
	
< 10
0.64		

192	
188	
192	
188	

> .99	
0.90	
> .98		
> .99	
0.90	
> .98		

0.47	
	
< 10
0.48		
0.47	
	
< 10
0.48		

54	
53	
54	
53	
54	
53	

> .99	
1.00	
> .95		
> .99	
1.00	
> .92		
> .99	
1.00	
> .92		

1.85	
	
< 10
1.89		
1.86	
	
< 10
1.87		
1.86	
	
< 10
1.87		

102	
99	
100	
98	
100	
98	

> .99	
0.98	
	
1.00	
< 10
> .98		
1.01		
> .99	
	
	
0.96	
< 10
0.96
> .97				
> .99	
	
	
0.96	
< 10
0.96
> .97				

144	
142	
144	
142	

> .99	
	
	
0.90	0.63
< 10
> .96				
> .99	
	
	
0.90	0.63
< 10
> .96				

189	
185	
189	
185	

> .99	
0.90	
> .97		
> .99	
0.90	
> .97		

0.48	
	
< 10
0.49		
0.48	
	
< 10
0.49		

60/16	37	 -D
60/16	37	 -D
60/16	A	 -A
60/16	A	 -A
60/16	B	 -E
60/16	B	 -E
60/16	B	 -E
60/16	B	 -E
60/16	40	 -D
60/16	A	 -A
60/16	A	 -A
60/16	37	 -D
60/16	A	 -A
60/16	A	 -A
60/16	B	 -E
60/16	B	 -E
60/16	B	 -E
60/16	B	 -E

See page 1-41 for Dimensions and Wiring Diagrams

For one lamp operation,
cap blue leads individually,
insulate to 600V.

For three lamp operation, cap
Blue/White leads individually,
insulate to 600V.

DIAGRAM A

DIAGRAM B

DIAGRAM 50

Page 1-­40

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

T5

TRIAD® T5 & T5HO ELECTRONIC
BALLASTS
Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	

&

T5HO

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.

	 Overall Dimensions	
	Draw #	
L	
	-C	
	-D	
	-E	

14.25”	
16.88”	
16.88”	

W	

> .99	
1.00	
> .92		
> .99	
1.00	
> .92		

1.95	
	
< 10
1.96		
1.95	
	
< 10
1.96		

> .99	
0.93	
> .97		
> .99	
0.93	
> .97		

0.96	
	
< 10
0.98		
0.96	
	
< 10
0.98		

> .99	
0.92	
> .96		
> .99	
0.92	
> .96		

0.70	
	
< 10
0.71		
0.70	
	
< 10
0.71		

> .99	
0.92	
> .97		
> .99	
0.92	
> .97		

0.53	
	
< 10
0.54		
0.53	
	
< 10
0.54		

60/16	A	 -A
60/16	A	 -A
60/16	A	 -A
60/16	A	 -A
60/16	B	 -E
60/16	B	 -E
60/16	B	 -E
60/16	B	 -E

Mounting Dimensions
H	
M	
X

1.18”	 1.00”	 13.75”	
1.18”	 1.00”	 16.20”	
1.74”	 1.18”	 16.28”	

—
—
—
-C, -D

-E

WIRING DIAGRAMS

DIAGRAM 4b

DIAGRAM 37

DIAGRAM 40

For one lamp operation, individually cap yellow
and yellow/black leads, insulate to 600V.

DIAGRAM 42

DIAGRAM 30

DIAGRAM 41

DIAGRAM 43

PAGE 1-­41

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

F54T5HOES (44W) - One Lamp Applications
	
	120	
0.43	
	
51
	 	
	
277	 B254PUNVPL-A	
		
0.20		
1	PS
	
	120	
0.43	
	
51
	 	
	
277	 B254PUNVPLHBA	
		
0.20		
	
F54T5HOES (44W) - Two Lamp Applications
	
	120	
0.81	
97	
	 	
	 277	 B254PUNVPL-A	
		
0.35	
95	
2	PAR-PS
	
	120	
0.81	
97	
	 	
	
277	 B254PUNVPLHBA	
		
0.35	
95	
	
F54T5HOES (44W) - Three Lamp Applications
	
	120	
1.10	
131	
	 	
	 277	 B454PUNVPL-E	
		
0.49	
130	
3	PAR-PS
	
	120	
1.10	
131	
	
B454PUNVPLHBE	
	
	
277	 		
0.49	
130	
	
F54T5HOES (44W) - Four Lamp Applications
	
	120	
1.46	
174	
	 	
	 277	 B454PUNVPL-E	
		
0.63	
171	
4	PAR-PS
	
	120	
1.46	
174	
	 	
	
277	 B454PUNVPLHBE	
		
0.63	
171	
	

Fluorescent-Electronic

F30T12,
F30T12ES,
F32T12

• Rapid Starting Options
• Standard & High
Performance Models

T12 Straight Lamps

• 1-3 Lamp Applications

TRIAD® ELECTRONIC BALLASTS
FOR (1), (2) AND (3)
F30T12, F30T12ES, & (2)F32T12 LAMPS

Lamp				
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
	
		 Starting	 Line	
Catalog	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	
Qty.	 Method	 Volts	
Number	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
F25T12 - Two Lamp Applications		
	
	120	
0.40	47
1.89
2 	 PAR-IS
B232IUNV-C	
	
> .98	 0.89	
	
< 10	 0/-18	
			
277		
0.17	 46			
1.93
F25T12 - Three Lamp Applications		
	
	120	
0.58	69
> .99	 0.90
1.30
3 	 PAR-IS
B332IUNVHP-A	
	
	
	
< 10	 0/-18	
			
277		
0.26	
68	
> .95	 0.91	
1.34
F25T12 - Four Lamp Applications		
	
	120	
0.77	91
> .99	
0.99
4 	 PAR-IS
B432IUNVHP-A	
	
0.90	
	
< 10	 0/-18	
			
277		
0.34	
88	
> .95		
1.02
F32T12 - One Lamp Applications		
	 1	
RS	
277	
B234SR277M-A*	
0.15	
33	
> .80	 0.94	
2.85	
< 30	 50/10	
F32T12 - Two Lamp Applications		
	
	120	 B234SR120M-A∆	
0.46	
54	
> .98	 0.90	
1.67	
< 10	 50/10	
2 	 SER-RS
			
277	
B234SR277M-A*	
0.21	
55	
> .90	 0.87	
1.58	
< 30	 50/10	

Wiring	
Diag.	
Dim.
21	

-C

6	

-A

7a	

-A

4	

-A

30	
4	

-A
-A

∆

Residential use only.
*Not for sale for use in the US.

	 Overall Dimensions	
	Draw #	
L	
	ST	
	-A	

9.50”	
9.50”	

W	

2.40”	
1.70”	

Mounting Dimensions
H	
M	
X

1.55”	 8.89”	 1.69”
1.18”	 8.89”	 1.69”
ST

WIRING DIAGRAMS

-A

DIAGRAM 47

DIAGRAM 44

Line

Black
White

DIAGRAM 48

BALLAST

Blue
Blue
Blue
Red

LAMP
LAMP
LAMP

For One lamp Operation, Individually
Cap blue leads, Insulate to 600V

For Two Lamp Operation,
Insulate one blue lead to 600V

For three lamp operation, cap any
blue lead, insulate to 600V

DIAGRAM 4

DIAGRAM 6

DIAGRAM 7a

DIAGRAM 30

DIAGRAM 21

PAGE 1-­42

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS
FOR (1) , (2) AND (3)
F40T12 AND F34T12ES LAMPS

• Standard & High
Performance Models
• Rapid Starting Options

F40T12
&

T12 Straight Lamps

F34T12ES

• 1-3 Lamp Applications
T12 U-Shaped Lamps

Wiring	
Diag.	
Dim.
4	
4	

-A
-A

30	
4	
4	

-A
-A
-A

4	
4	

-A
-A

30	
4	
4	

-A
-A
-A

∆

Residential use only.
* Not for sale for use in the US.

	 Overall Dimensions	
	Draw #	
L	
	-A	

9.50”	

W	

1.70”	

Mounting Dimensions
H	
M	
X

WIRING DIAGRAMS

1.18”	 8.89”	 1.69”

-A
For One Lamp Applications, individually
cap blue leads, Insulate fo 600V

DIAGRAM 4

PAGE 1-­43

DIAGRAM 30

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

Lamp				
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
	
		 Starting	 Line	
Catalog	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	
Qty.	 Method	 Volts	
Number	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
F40T12 - One Lamp Applications
			
220	 B240R220-A*	
0.20	
44	
> .99	 1.04	
2.38	
< 10	 50/10	
1	RS
	
	
277	 B234SR277M-A*	
0.17	
42	
> .88	 0.94	
2.24	
< 30	 50/10	
	F40T12 - Two Lamp Applications
	
	 120	B234SR120M-A∆	
0.58	
69	
> .98	 0.90	
1.30	
< 10	 50/10	
2	SER-RS
			
277	 B234SR277M-A*	
0.26	
70	
> .90	 0.87	
1.24	
< 30	 50/10	
	 2	 PAR-RS	 220	 B240R200-A*	
0.32	
70	
> .99	 0.90	
1.29	
< 10	 50/10	
F40T12ES (34W) - One Lamp Applications
			
220	 B240R200-A*	
0.17	
36	
> .99	 1.04	
2.86	
< 10	 60/16	
1	RS
	
	
277	 B234SR277M-A*	
0.15	
35	
> .80	 0.94	
2.69	
< 30	 60/16	
	F40T12ES (34W) - Two Lamp Applications
	
	 120	B234SR120M-A∆	
0.48	
58	
> .98	 0.86	
1.48	
< 10	 60/16	
2	SER-RS
			
277	 B234SR277M-A*	
0.23	
60	
> .90	 0.87	
1.45	
< 30	 50/10	
	 2	 PAR-RS	 220	 B240R200-A*	
0.27	
59	
> .99	 0.90	
1.52	
< 10	 60/16	

T12

SLIMLINE

Fluorescent-Electronic

TRIAD® ELECTRONIC BALLASTS

• Standard & High
Performance Models
Slimline Lamps

• Instant Starting Options

FOR F48T12, F48T12ES, F60T12, F64T12 &
F72T12 LAMPS

• 1-2 Lamp Applications

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
F48T12 - One Lamp Applications
	1	 IS	 120	
B260IUNVHP	
			
277			
F48T12 - Two Lamp Applications
	 2	 PAR-IS	 120	
B260I120M-A*	
			
120	
B260IUNVHP	
			
277			
	 F48T12ES - One Lamp Applications
	1	 IS	 120	
B260IUNVHP	
			
277			
	F48T12ES - Two Lamp Applications
	2	 PAR-IS	 120	
B260IUNVHP	
			
277			
F60T12 - One Lamp Applications
	1	 IS	 120	
B260IUNVHP	
			
277			
F60T12 - Two Lamp Applications
	2	 PAR-IS	 120	
B260IUNVHP	
			
277			
F64T12 - One Lamp Applications
	1	 IS	 120	
B260IUNVHP	
			
277			
F64T12 - Two Lamp Applications
	2	 PAR-IS	 120	
B260IUNVHP	
			
277			
F72T12 - One Lamp Applications
	1	 IS	 120	
B260IUNVHP	
			
277			

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.39	
	
	
47
> .95	 1.10
0.18				

	
2.34

< 10	

0/-18	

14	

SL

50/10	

14	

-A

0/-18	

14	

SL

0.62	
0.61	
0.27	

68	
75	
74	

> .90	 0.90	
1.32	
< 30	
> .98
	1.27	
	0.95
< 10	
> .95		
1.28

0.32	
0.15	

38	
39	

> .98
	2.89	
	1.10
< 10	
> .95		
2.82

60/16	

14	

SL

0.57	67	
	1.39	
> .95	 0.93
< 10	
0.25	 66			
1.41

60/16	

14	

SL

0.49	
	
58
0.22		

< 10	

0/-18	

14	

SL

0.77	92	
	1.00	
> .98	 0.92
< 10	
0.33	 91			
1.01

0/-18	

14	

SL

0.51	
0.35	

> .98
	1.80	
	1.10
< 10	
> .95		
1.15

0/-18	

14	

SL

0.81	97	
	0.95	
> .98	 0.92
< 10	
0.35	 96			
0.96

0/-18	

14	

SL

0.55	68	
	1.56	
> .95	 1.06
< 10	
0.25	 67			
1.58

0/-18	

14	

SL

61	
96	

> .98
	
	1.10
> .95		

	
1.90

* Residential use only.
	 Overall Dimensions	
	Draw #	
L	
	SL	
	-A	

11.75”	
9.50”	

W	

3.13”	
1.70”	

Mounting Dimensions
H	
M	
X

WIRING DIAGRAMS

1.78”	 11.14”	 2.00”
1.18”	 8.89”	 1.69”

For One Lamp Operation, Insulate one blue lead to 600V

SL

DIAGRAM 14

-A

PAGE 1-­44

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS

• Standard & High
Performance Models

F72T12(cont.), F84T12, F96T12 & F96T12ES
LAMPS

• Instant Starting Options

SLIMLINE

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.90	
105	 > .95	 0.90	
0.86	
< 30	
0.90	109	
	0.83	
> .99	 0.91
< 10	
0.39	 107			
0.85

50/10	

14	

-A

0/-18	

14	

SL

0.63	76	
	1.45	
> .98	 1.10
< 10	
0.28	 75			
1.47

0/-18	

14	

SL

1.03	123	
	0.72	
> .98	 0.88
< 10	
0.44	 120			
0.73

0/-18	

14	

SL

0.70	85	
	1.24	
> .98	 1.05
< 10	
0.31	 84			
1.25

0/-18	

14	

SL

1.16	139	
	0.63	
> .99	 0.88
< 10	
0.50	 137			
0.64

0/-18	

14	

SL

0.61	
66	
> .90	 1.09	
1.65	
< 30	
0.59	72	
	1.43	
> .98	 1.03
< 10	
0.26	 70			
1.47

60/16	

14	

-A

60/16	

14	

SL

0.90	
105	 > .95	 0.88	
0.84	
< 30	
0.96	112	
	0.79	
> .99	 0.88
< 10	
0.40	 110			
0.80

60/16	

14	

-A

60/16	

14	

SL

* Residential use only.
IS = Instant Start
PRS = Programmed Rapid Start

RS = Rapid Start
PAR-IS = Parallel Instant Start

	 Overall Dimensions	
	Draw #	
L	
	SL	
	-A	

11.75”	
9.50”	

SL

W	

3.13”	
1.70”	

STARTING METHOD LEGEND

PAR-PRS = Parallel Programmed Rapid Start
SER-PRS = Series Programmed Rapid Start

Mounting Dimensions
H	
M	
X

1.78”	 11.14”	 2.00”
1.18”	 8.89”	 1.69”

PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start

SER-IS = Series Instant Start

WIRING DIAGRAMS

For One Lamp Operation, Insulate one blue lead to 600V

-A

DIAGRAM 14

PAGE 1-­45

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
	F72T12 - Two Lamp Applications
	 2	 PAR-IS	 120	 B260I120M-A*	
			
120	
B260IUNVHP	
			
277			
F84T12 - One Lamp Applications
	1	 IS	
120	
B260IUNVHP	
			
277			
F84T12 - Two Lamp Applications
	2	 PAR-IS	 120	
B260IUNVHP	
			
277			
F96T12 - One Lamp Applications
	1	 IS	
120	
B260IUNVHP	
			
277			
F96T12 - Two Lamp Applications
	2	 PAR-IS	 120	
B260IUNVHP	
			
277			
	F96T12ES - One Lamp Applications
	 1	
IS	
120	 B260I120M-A*	
			
120	
B260IUNVHP	
			
277			
	F96T12ES - Two Lamp Applications
	 2	 PAR-IS	 120	 B260I120M-A*	
			
120	
B260IUNVHP	
			
277			

• 1-2 Lamp Applications

T12

Slimline Lamps

T12HO

• High Performance
Models

TRIAD® ELECTRONIC BALLASTS

• Rapid Starting Options
• 2 Lamp Applications

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	

FOR T12 HIGH
OUTPUT LAMPS

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.

Fluorescent-Electronic

F48T12HO - One Lamp Applications
	
	120	
0.46	
	
> .98
	
	
< 10
1	PS
B295PUNVHE-S	
55
	0.93
1.69
	-20/-29	
			
277		
0.22		
> .90			
< 12
F48T12HO - Two Lamp Applications
	
	120	
0.88	
105	
> .98
	0.86	
2	SER-PS
B295PUNVHE-S	
	0.90
< 10	 -20/-29	
			
277		
0.39	
104	
> .95		
0.87
	F60T12HO - One Lamp Applications
	
	120	
0.56	
	
> .98
	
	
1	PS
B295PUNVHE-S	
67
	0.92
1.37
< 10	 -20/-29	
			 277		
0.26		> .92		
	F60T12HO - Two Lamp Applications
	
	120	
1.08	
127	
> .98
	0.70	
2	SER-PS
B295PUNVHE-S	
	0.89
< 10	 -20/-29	
			
277		
0.47	
126	
> .95		
0.71
	F72T12/BL/HO - Two Lamp Applications
	 2	 SER-RS	 120	 493B2	
1.60	
180	
> .90	 1.00	
0.56	
< 25	 50/10	
	F72T12HO - One Lamp Applications
	
	120	
0.70	
	
> .98
	
	
1	PS
B295PUNVHE-S	
83
	0.92
1.11
< 10	 -20/-29	
			 277		
0.31		> .95			
	F72T12HO - Two Lamp Applications
	
	120	
1.34	157	
	0.56	
2	SER-PS
B295PUNVHE-S	
> .98	 0.88
< 10	 -20/-29	
			
277		
0.57	 155			
0.57
	F73T12/BL/HO - Two Lamp Applications
	 2	 SER-RS	 120	 493B2	
1.60	
180	
> .90	 1.00	
0.56	
< 25	 50/10	
	F96T12HO - One Lamp Applications
	
	120	
0.88	
104	
> .98
	0.88	
1	PS
B295PUNVHE-S	
	0.92
< 10	 -20/-29	
			
277		
0.38	
103	
> .95		
0.89
	F96T12HO - Two Lamp Applications
	
	120	
1.72	204	
	0.43	
2	SER-PS
B295PUNVHE-S	
> .98	 0.88
< 10	 -20/-29	
			
277		
0.72	 197			
0.45
	F96T12HOES (95W) - One Lamp Applications
	
	120	
0.73	
	
> .98
	
	
1	PS
B295PUNVHE-S	
87
	0.92
1.06
< 10	 60/16	
			 277		
0.32		> .95		
	F96T12HOES (95W) - Two Lamp Applications
	
	120	
1.45	170	
	0.52	
2	SER-PS
B295PUNVHE-S	
> .98	 0.88
< 10	 -20/-29	
			
277		
0.61	 167			
0.53
	 Overall Dimensions	
	Draw #	
L	
	ST	
	-S	

9.50”	
11.75”	

W	

Mounting Dimensions
H	
M	
X

80	

-S

80	

-S

80	

-S

80	

-S

4	

ST

80	

-S

80	

-S

4	

ST

80	

-S

80	

-S

80	

-S

80	

-S

WIRING DIAGRAMS

2.40”	 1.55”	 8.89”	 1.69”
1.70”	 1.18”	 11.19”	 1.05”

DIAGRAM 40

ST

SL

DIAGRAM 4

DIAGRAM 80

PAGE 1-­46

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

TRIAD® ELECTRONIC BALLASTS

• Programmed Rapid
Starting Options

FOR F6T2, F8T2, F11T2 AND F13T2 LAMPS

• 1-2 Lamp Applications

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
	F6T2 - One And Two Lamp Applications
	
	120	
2	SER-PS
ES1786X	
	
	
277			
	
	
	120	
1	PS
ES1786X	
			
277			
	F8T2 - One And Two Lamp Applications
	
	120	
2	SER-PS
ES1786X	
			
277			
	
	120	
1	PS
ES1786X	
			
277			
F11T2 - One And Two Lamp Applications
	
	120	
2	SER-PS
ES1786X	
			
277			
	
	120	
1	PS
ES1786X	
			
277			
F13T2 - One And Two Lamp Applications
	
	120	
2	SER-PS
ES1786X	
			
277			
	
	120	
1	PS
ES1786X	
			
277			

T2

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
Factor (BEF)	 %	
Temp	
Diag.	
Dim.
0.12	14	
	7.14	
> .97	 1.00
< 10	
0.07	 15			
6.67
0.07	8	
	12.50	
> .97	 1.00
< 10	
0.05	
9			
11.11	
0.17	20	
	5.00	
> .97	 1.00
< 10	
0.08	 21			
4.76
0.10	
11	
> .97	 1.00	
9.09	
< 10	
0.06	

37	

ESX

0/-18	

40	

ESX

0/-18	

37	

ESX

0/-18	

40	

ESX

26	

> .97	

1.00	

3.85	

< 10	

0/-18	

37	

ESX

15	

> .97	

1.00	

6.67	

< 10	

0/-18	

40	

ESX

0/-18	

37	

ESX

0/-18	

40	

ESX

0.27	31	
	3.23	
> .97	 1.00
< 10	
0.13	 32			
3.13	
0.15	16	
	6.25	
> .97	 1.00
< 10	
0.08	 17			
5.88

	

STARTING METHOD LEGEND
IS = Instant Start
PRS = Programmed Rapid Start

	 Overall Dimensions	
	Draw #	
L	
	ESX	

14.13”	

RS = Rapid Start
PAR-IS = Parallel Instant Start

W	

1.24”	

PAR-PRS = Parallel Programmed Rapid Start
SER-PRS = Series Programmed Rapid Start

Mounting Dimensions
H	
M	
X

0.73”	

13.78”	

PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start

SER-IS = Series Instant Start

WIRING DIAGRAMS

—

DIAGRAM 37

ESX

DIAGRAM 40

PAGE 1-­47

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent-Electronic

0.20	
0.09	
0.12	
0.07

0/-18	

Energy Management System
DCL® with DEMANDflex®
DEMANDflex® ballasts are high efficiency program start
ballasts with the flexibility to be tuned at the circuit level
to fixed power levels during installation. They are fully
compatible with occupancy sensors and exceed the CEE
requirements for high efficiency program start T8
ballasts. DEMANDflex® ballasts having tuning capabilities with ranges from 100% to 50% power levels, making
them applicable for a wide range of lighting installations.
Installations can start with DEMANDflex® ballasts and
after installation, the ballasts can be tuned to maximize
energy savings with fixed light levels. No dimming
control wires are associated with DEMANDflex® ballasts
which makes them easy to install in all existing fluorescent lighting applications. DEMANDflex® ballasts can also
be integrated with DCL® controls to be part of the most
cost-effective lighting system available.
DCL® controls allow for local control with energy management systems and external control via the internet for
networked managed systems. DCL® controls allow for
integration with utility demand response programs that
provide for improved pricing contracts to end-users in
exchange for the utility to have the ability to lower
lighting power levels during periods of high demand.

DCL/DEMANDflex

Universal Lighting Technologies is a member of the Panasonic Group

Product Overview
DEMANDflex® Ballasts
n

Power level tuning potential to 50%

	

–Set the circuit power level at installation

	

–Typical 10% to 15% power reduction

n

Install the same as standard PRS ballasts

	

–No control wires necessary

	

–Standard mounting footprint

	

–Same wiring as program rapid start ballasts

n

High efficiency program start operation

	

–Exceeds CEE T8 requirements

	

–Compatible with occupancy sensors

n

NEMA premium

	

–Exceeds CEE T8 requirements

	

–Compatible with occupancy sensors

DCL® Controlled Systems
n

	

–Avoid high peak charges

	

–Reduce demand costs

n

Programmable fade rates

	

–Gradual transitions

	

–No disruptions

n

	
n

DCL/DEMANDflex

Reduces lighting power by up to 50%

Use existing power connections to communicate to the ballasts
–No control wires
Implement with various controls and systems

	

–BAS Systems

	

–Photo Cells

	

–Occupancy Sensors

	

–Contact Closure

For more information contact Universal or visit www.unvlt.com.

PAGE 2-2

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

DEMANDflex®
FOR (1), (2), (3) & (4) LAMPS

DEMANDflex

Universal DCL® Dimming
Programmed Rapid Start
1, 2, 3, & 4 Lamp Applications
Visit www.unvlt.com for a comprehensive
description of the DCL® system and
DEMANDflex® ballasts

•
•
•
•

T8

Certification	Line	 Input	 Power	 Ballast	 Ballast		
	 Lamp	 				
Min. F/C	
		 Starting	Line	
Catalog					 Current	 Power	Factor	Factor	 Efficacy	 THD	 Start	 Wiring	
	 Qty.	 Method	 Volts	
Number		
c			 (Amps)	 (Watts)	 (PF)	
(BF)	 Factor (BEF)	 %	
Temp	 Diag.	 Dim.

F32T8 - One Lamp Applications

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

0.24	
0.11	
0.11	
0.05	
0.32	
0.15	
0.14	
0.07	
0.20	
0.09	
0.09	
0.05	

29	
14	
29	
14	
38	
18	
39	
19	
24	
11	
24	
12	

> .95	
> .95	
> .95	
> .90	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	

0.88	
0.28	
0.88	
0.28	
1.15	
0.50	
1.15	
0.50	
0.68	
0.18	
0.68	
0.18	

3.01	
2.05	
3.03	
1.96	
3.03	
2.78	
2.95	
2.63	
2.85	
1.64	
2.85	
1.57	

< 10	
< 15	
< 10	
< 15	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	

32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	

12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	

-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A

B232PUNVDR-A @ 100%	
			 120	
	
		 B232PUNVDR-A @ 50%	
	
B232PUNVDR-A @ 100%	
			 277	
				 B232PUNVDR-A @ 50%	
B232PUNVDRH-A @ 100%	
			 120	
	 2 	 PRS		 B232PUNVDRH-A @ 50%	
B232PUNVDRH-A @ 100%	
			 277	
				 B232PUNVDRH-A @ 50%	
B232PUNVDRL-A @ 100%	
			 120	
	
		 B232PUNVDRL-A @ 50%	
	
B232PUNVDRL-A @ 100%	
			 277	
				 B232PUNVDRL-A @ 50%	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

0.47	
0.22	
0.20	
0.10	
0.62	
0.30	
0.26	
0.13	
0.40	
0.19	
0.17	
0.09	

57	
28	
56	
28	
75	
37	
73	
36	
47	
24	
47	
24	

> .95	
> .95	
> .95	
> .95	
> .95	
> .90	
> .95	
> .90	
> .95	
> .95	
> .95	
> .95	

0.87	
0.34	
0.87	
0.35	
1.15	
0.50	
1.15	
0.50	
0.71	
0.19	
0.71	
0.19	

1.53	
1.20	
1.56	
1.22	
1.53	
1.35	
1.58	
1.39	
1.51	
0.81	
1.51	
0.81	

< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	

32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	

12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	

-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A

B332PUNVDR-A @ 100%	
			 120	
	
		 B332PUNVDR-A @ 50%	
	
B332PUNVDR-A @ 100%	
			 277	
				 B332PUNVDR-A @ 50%	
B332PUNVDRL-A @ 100%	
			 120	
	 3 	 PRS		 B332PUNVDRL-A @ 50%	
	
B332PUNVDRL-A @ 100%	
		277	
				 B332PUNVDRL-A @ 50%	
B332PUNVDRH-E @ 100%	
			 120	
	
		 B332PUNVDRH-E @ 50%	
	
B332PUNVDRH-E @ 100%	
			 277	
				 B332PUNVDRH-E @ 50%	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

0.70	
0.34	
0.30	
0.16	
0.59	
0.29	
0.25	
0.13	
0.95	
0.48	
0.41	
0.21	

85	
42	
83	
41	
72	
36	
72	
36	
115	
57	
111	
55	

> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	

0.87	
0.35	
0.87	
0.35	
0.71	
0.22	
0.71	
0.22	
1.15	
0.50	
1.15	
0.50	

1.02	
0.83	
1.05	
0.85	
0.99	
0.61	
0.99	
0.61	
1.00	
0.88	
1.04	
0.91	

< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	

32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	

12c	
12c	
12c	
12c	
12c	
12c	
12c	
12c	
12d	
12d	
12d	
12d	

-A
-A
-A
-A
-A
-A
-A
-A
-E
-E
-E
-E

B432PUNVDR-E @ 100%	
			 120	
	
		 B432PUNVDR-E @ 50%	
	
B432PUNVDR-E @ 100%	
			 277	
	 4 	 PRS		 B432PUNVDR-E @ 50%	
B432PUNVDRL-E @ 100%	
			 120	
	
		 B432PUNVDRL-E @ 50%	
	
B432PUNVDRL-E @ 100%	
			 277	
				 B432PUNVDRL-E @ 50%	

•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	
•	
•	
•	
•	
•	

0.96	
0.48	
0.41	
0.20	
0.78	
0.37	
0.34	
0.17	

116	
58	
112	
56	
93	
47	
93	
47	

> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	

0.88	
0.35	
0.88	
0.35	
0.71	
0.21	
0.71	
0.21	

0.75	
0.60	
0.79	
0.63	
0.76	
0.45	
0.76	
0.45	

< 10	
< 10	
< 10	
< 15	
< 10	
< 15	
< 10	
< 15	

32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	

12e	
12e	
12e	
12e	
12e	
12e	
12e	
12e	

-E
-E
-E
-E
-E
-E
-E
-E

F32T8 - Two Lamp Applications

F32T8 - Three Lamp Applications

F32T8 - Four Lamp Applications

See page 2-7 for Dimensions and Wiring Diagrams

PAGE 2-3

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

DEMANDflex

B232PUNVDR-A @ 100%	
			 120	
	
		 B232PUNVDR-A @ 50%	
	
B232PUNVDR-A @ 100%	
			 277	
				 B232PUNVDR-A @ 50%	
B232PUNVDRH-A @ 100%	
			 120	
	 1 	 PRS		 B232PUNVDRH-A @ 50%	
B232PUNVDRH-A @ 100%	
			 277	
				 B232PUNVDRH-A @ 50%	
B232PUNVDRL-A @ 100%	
			 120	
	
		 B232PUNVDRL-A @ 50%	
	
B232PUNVDRL-A @ 100%	
			 277	
				 B232PUNVDRL-A @ 50%	

DEMANDflex
T8

•
•
•
•

DEMANDflex®

 niversal DCL® Dimming
U
Programmed Rapid Start
1, 2, 3, & 4 Lamp Applications
Visit www.unvlt.com for a comprehensive
description of the DCL system and
DEMANDflex ballasts

FOR (1), (2), (3) & (4) LAMPS

Certification	Line	 Input	 Power	 Ballast	 Ballast		
	 Lamp	 				
Min. F/C	
		 Starting	Line	
Catalog					 Current	 Power	Factor	Factor	 Efficacy	 THD	 Start	 Wiring	
	 Qty.	 Method	 Volts	
Number		
c			 (Amps)	 (Watts)	 (PF)	
(BF)	 Factor (BEF)	 %	
Temp	 Diag.	 Dim.

F25T8 - One Lamp Applications

B232PUNVDR-A @ 100%	
			 120	
	
		 B232PUNVDR-A @ 50%	
	
B232PUNVDR-A @ 100%	
			 277	
				 B232PUNVDR-A @ 50%	
B232PUNVDRH-A @ 100%	
			 120	
	 1 	 PRS		 B232PUNVDRH-A @ 50%	
B232PUNVDRH-A @ 100%	
			 277	
				 B232PUNVDRH-A @ 50%	
B232PUNVDRL-A @ 100%	
			 120	
	
		 B232PUNVDRL-A @ 50%	
	
B232PUNVDRL-A @ 100%	
			 277	
				 B232PUNVDRL-A @ 50%	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

0.19	
0.10	
0.08	
0.05	
0.25	
0.12	
0.11	
0.06	
0.15	
0.08	
0.07	
0.04	

22	
12	
22	
13	
30	
14	
30	
15	
18	
10	
18	
10	

> .95	
> .95	
> .95	
> .90	
> .95	
> .95	
> .95	
> .90	
> .95	
> .95	
> .95	
> .95	

0.87	
0.35	
0.88	
0.35	
1.16	
0.50	
1.16	
0.50	
0.69	
0.18	
0.69	
0.18	

4.00	
2.93	
3.95	
2.82	
3.87	
3.57	
3.81	
3.33	
3.85	
1.84	
3.77	
1.75	

< 10	
< 15	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 15	
< 10	
< 15	

32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	

12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	

-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A

B232PUNVDR-A @ 100%	
			 120	
	
		 B232PUNVDR-A @ 50%	
	
B232PUNVDR-A @ 100%	
			 277	
				 B232PUNVDR-A @ 50%	
B232PUNVDRH-A @ 100%	
			 120	
	 2 	 PRS		 B232PUNVDRH-A @ 50%	
B232PUNVDRH-A @ 100%	
			 277	
				 B232PUNVDRH-A @ 50%	
B232PUNVDRL-A @ 100%	
			 120	
	
		 B232PUNVDRL-A @ 50%	
	
B232PUNVDRL-A @ 100%	
			 277	
				 B232PUNVDRL-A @ 50%	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

0.36	
0.19	
0.16	
0.09	
0.46	
0.21	
0.20	
0.10	
0.30	
0.15	
0.13	
0.07	

44	
23	
43	
23	
55	
26	
55	
26	
36	
18	
35	
18	

> .95	
> .95	
> .95	
> .95	
> .95	
> .90	
> .95	
> .90	
> .95	
> .95	
> .95	
> .95	

0.87	
0.35	
0.87	
0.35	
1.15	
0.50	
1.15	
0.50	
0.69	
0.19	
0.69	
0.19	

2.01	
1.56	
2.05	
1.53	
2.09	
1.92	
2.08	
1.92	
1.93	
1.06	
1.95	
1.03	

< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	

32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	

12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	

-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A

B332PUNVDR-A @ 100%	
			 120	
	
		 B332PUNVDR-A @ 50%	
	
B332PUNVDR-A @ 100%	
			 277	
				 B332PUNVDR-A @ 50%	
B332PUNVDRL-A @ 100%	
			 120	
	 3 	 PRS		 B332PUNVDRL-A @ 50%	
	
B332PUNVDRL-A @ 100%	
		277	
				 B332PUNVDRL-A @ 50%	
B332PUNVDRH-E @ 100%	
			 120	
	
		 B332PUNVDRH-E @ 50%	
	
B332PUNVDRH-E @ 100%	
			 277	
				 B332PUNVDRH-E @ 50%	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

0.55	
0.27	
0.24	
0.13	
0.47	
0.24	
0.21	
0.11	
0.74	
0.35	
0.33	
0.16	

66	
33	
65	
32	
56	
28	
55	
29	
89	
42	
89	
43	

> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .90	
> .95	
> .95	
> .95	
> .95	

0.87	
0.35	
0.87	
0.35	
0.71	
0.23	
0.71	
0.23	
1.17	
0.50	
1.17	
0.50	

1.32	
1.06	
1.34	
1.09	
1.27	
0.81	
1.29	
0.80	
1.31	
1.19	
1.31	
1.16	

< 10	
< 10	
< 10	
< 15	
< 10	
< 10	
< 10	
< 10	
< 10	
< 15	
< 10	
< 15	

32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	

12c	
12c	
12c	
12c	
12c	
12c	
12c	
12c	
12d	
12d	
12d	
12d	

-A
-A
-A
-A
-A
-A
-A
-A
-E
-E
-E
-E

B432PUNVDR-E @ 100%	
			 120	
	
		 B432PUNVDR-E @ 50%	
	
B432PUNVDR-E @ 100%	
			 277	
	 4 	 PRS		 B432PUNVDR-E @ 50%	
B432PUNVDRL-E @ 100%	
			 120	
	
		 B432PUNVDRL-E @ 50%	
	
B432PUNVDRL-E @ 100%	
			 277	
				 B432PUNVDRL-E @ 50%	

•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	
•	
•	
•	
•	
•	

0.75	
0.37	
0.33	
0.17	
0.61	
0.31	
0.27	
0.15	

90	
44	
89	
44	
73	
37	
72	
38	

> .95	
> .95	
> .95	
> .90	
> .95	
> .95	
> .95	
> .90	

0.89	
0.35	
0.89	
0.35	
0.71	
0.21	
0.71	
0.21	

0.99	
0.80	
1.00	
0.80	
0.97	
0.56	
0.98	
0.56	

< 10	
< 15	
< 10	
< 15	
< 10	
< 15	
< 10	
< 15	

32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	

12e	
12e	
12e	
12e	
12e	
12e	
12e	
12e	

-E
-E
-E
-E
-E
-E
-E
-E

F25T8 - Two Lamp Applications

F25T8 - Three Lamp Applications

DEMANDflex

F25T8 - Four Lamp Applications

See page 2-7 for Dimensions and Wiring Diagrams

PAGE 2-4

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

DEMANDflex®

•
•
•
•

FOR (1), (2), (3) & (4) LAMPS

DEMANDflex

Universal DCL® Dimming
Programmed Rapid Start
1, 2, 3, & 4 Lamp Applications
Visit www.unvlt.com for a comprehensive
description of the DCL system and
DEMANDflex ballasts

T8

Certification	Line	 Input	 Power	 Ballast	 Ballast		
	 Lamp	 				
Min. F/C	
		 Starting	Line	
Catalog					 Current	 Power	Factor	Factor	 Efficacy	 THD	 Start	 Wiring	
	 Qty.	 Method	 Volts	
Number		
c			 (Amps)	 (Watts)	 (PF)	
(BF)	 Factor (BEF)	 %	
Temp	 Diag.	 Dim.

F17T8 - One Lamp Applications

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

0.14	
0.08	
0.06	
0.04	
0.18	
0.09	
0.09	
0.05	
0.11	
0.09	
0.05	
0.04	

16	
10	
17	
10	
22	
11	
22	
11	
13	
10	
13	
11	

> .95	
> .95	
> .95	
> .85	
> .95	
> .95	
> .95	
> .90	
> .95	
> .95	
> .95	
> .85	

0.92	
0.27	
0.92	
0.27	
1.15	
0.50	
1.15	
0.50	
0.70	
0.20	
0.70	
0.20	

5.65	
2.81	
5.48	
2.66	
5.23	
4.63	
5.23	
4.55	
5.47	
1.98	
5.22	
1.87	

< 10	
< 15	
< 10	
< 15	
< 10	
< 15	
< 10	
< 15	
< 10	
< 15	
< 10	
< 15	

32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	

12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	
12a	

-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A

B232PUNVDR-A @ 100%	
			 120	
	
		 B232PUNVDR-A @ 50%	
	
B232PUNVDR-A @ 100%	
			 277	
				 B232PUNVDR-A @ 50%	
B232PUNVDRH-A @ 100%	
			 120	
	 2 	 PRS		 B232PUNVDRH-A @ 50%	
B232PUNVDRH-A @ 100%	
			 277	
				 B232PUNVDRH-A @ 50%	
B232PUNVDRL-A @ 100%	
			 120	
	
		 B232PUNVDRL-A @ 50%	
	
B232PUNVDRL-A @ 100%	
			 277	
				 B232PUNVDRL-A @ 50%	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

0.25	
0.13	
0.13	
0.06	
0.32	
0.16	
0.14	
0.07	
0.21	
0.12	
0.09	
0.06	

30	
16	
30	
16	
38	
19	
39	
19	
25	
15	
25	
15	

> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .95	
> .90	
> .95	
> .95	
> .95	
> .95	

0.90	
0.27	
0.90	
0.27	
1.16	
0.50	
1.16	
0.50	
0.69	
0.19	
0.69	
0.19	

3.00	
1.72	
3.00	
1.67	
3.05	
2.63	
2.97	
2.63	
2.78	
1.29	
2.76	
1.24	

< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 15	
< 10	
< 10	

32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	

12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	
12b	

-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A

B332PUNVDR-A @ 100%	
			 120	
	
		 B332PUNVDR-A @ 50%	
	
B332PUNVDR-A @ 100%	
			 277	
				 B332PUNVDR-A @ 50%	
B332PUNVDRL-A @ 100%	
			 120	
	 3 	 PRS		 B332PUNVDRL-A @ 50%	
	
B332PUNVDRL-A @ 100%	
		277	
				 B332PUNVDRL-A @ 50%	
B332PUNVDRH-E @ 100%	
			 120	
	
		 B332PUNVDRH-E @ 50%	
	
B332PUNVDRH-E @ 100%	
			 277	
				 B332PUNVDRH-E @ 50%	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	
•	

0.40	
0.20	
0.18	
0.10	
0.33	
0.18	
0.15	
0.09	
0.54	
0.25	
0.24	
0.12	

48	
24	
48	
24	
40	
22	
40	
23	
65	
32	
65	
32	

> .95	
> .95	
> .95	
> .90	
> .95	
> .95	
> .95	
> .85	
> .95	
> .95	
> .95	
> .90	

0.89	
0.36	
0.89	
0.36	
0.73	
0.23	
0.73	
0.23	
1.19	
0.51	
1.19	
0.51	

1.86	
1.51	
1.86	
1.51	
1.83	
1.05	
1.83	
1.02	
1.83	
1.59	
1.84	
1.59	

< 10	
< 10	
< 10	
< 15	
< 10	
< 10	
< 10	
< 15	
< 10	
< 15	
< 10	
< 15	

32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	

12c	
12c	
12c	
12c	
12c	
12c	
12c	
12c	
12d	
12d	
12d	
12d	

-A
-A
-A
-A
-A
-A
-A
-A
-E
-E
-E
-E

B432PUNVDR-E @ 100%	
			 120	
	
		 B432PUNVDR-E @ 50%	
	
B432PUNVDR-E @ 100%	
			 277	
	 4 	 PRS		 B432PUNVDR-E @ 50%	
B432PUNVDRL-E @ 100%	
			 120	
	
		 B432PUNVDRL-E @ 50%	
	
B432PUNVDRL-E @ 100%	
			 277	
				 B432PUNVDRL-E @ 50%	

•	
•	
•	
•	
•	
•	
•	
•	

•	
•	
•	
•	
•	
•	
•	
•	

0.53	
0.27	
0.24	
0.13	
0.43	
0.26	
0.20	
0.12	

64	
32	
63	
32	
52	
31	
52	
31	

> .95	
> .95	
> .95	
> .90	
> .95	
> .95	
> .95	
> .90	

0.91	
0.35	
0.91	
0.35	
0.73	
0.21	
0.73	
0.21	

1.42	
1.09	
1.44	
1.09	
1.41	
0.69	
1.41	
0.67	

< 10	
< 15	
< 10	
< 15	
< 10	
< 15	
< 10	
< 15	

32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	
32/0 	
32/0	

12e	
12e	
12e	
12e	
12e	
12e	
12e	
12e	

-E
-E
-E
-E
-E
-E
-E
-E

F17T8 - Two Lamp Applications

F17T8 - Three Lamp Applications

F17T8 - Four Lamp Applications

See page 2-7 for Dimensions and Wiring Diagrams

FOR MORE INFORMATION CALL

PAGE 2-5

1-800-BALLAST
(225-5278)

DEMANDflex

B232PUNVDR-A @ 100%	
			 120	
	
		 B232PUNVDR-A @ 50%	
	
B232PUNVDR-A @ 100%	
			 277	
				 B232PUNVDR-A @ 50%	
B232PUNVDRH-A @ 100%	
			 120	
	 1 	 PRS		 B232PUNVDRH-A @ 50%	
B232PUNVDRH-A @ 100%	
			 277	
				 B232PUNVDRH-A @ 50%	
B232PUNVDRL-A @ 100%	
			 120	
	
		 B232PUNVDRL-A @ 50%	
	
B232PUNVDRL-A @ 100%	
			 277	
				 B232PUNVDRL-A @ 50%	

DEMANDflex
T5, T5HO & TT5

•
•
•
•
•

 niversal DCL® Dimming
U
Programmed Rapid Start
2 Lamp Applications for T5HO
1 & 2 Lamp Applications for T5
Visit www.unvlt.com for a comprehensive
description of the DCL system and DEMANDflex ballasts

DEMANDflex®
FOR T5 & T5HO LAMPS

Certification		
	 Lamp	 				
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
		 Starting	Line	
Catalog					 Current	 Power	Factor	Factor	 Efficacy	 THD	 Start	 Wiring	
	 Qty.	 Method	 Volts	
Number		
c			 (Amps)	 (Watts)	 (PF)	
(BF)	 Factor (BEF)	 %	
Temp	 Diag.	 Dim.

F28T5 - One Lamp Applications

B128PUNVDRH-D @ 100%	
			 120	
	 1 	 PRS		 B128PUNVDRH-D @ 50%	
B128PUNVDRH-D @ 100%	
			 277	
				 B128PUNVDRH-D @ 50%	

•	
•	
•	
•	

•	
•	
•	
•	

0.32	
0.16	
0.14	
0.08	

37	
19	
37	
19	

> .99	
> .99	
> .96	
> .88	

1.15	
0.38	
1.15	
0.38	

3.11	
2.00	
3.11	
2.00	

< 10	
< 10	
< 10	
< 10	

50/10 	
50/10	
50/10 	
50/10	

12g	
12g	
12g	
12g	

-D
-D
-D
-D

B228PUNVDRH-D @ 100%	
			 120	
	 2 	 PRS		 B228PUNVDRH-D @ 50%	
B228PUNVDRH-D @ 100%	
			 277	
				 B228PUNVDRH-D @ 50%	

•	
•	
•	
•	

•	
•	
•	
•	

0.60	
0.30	
0.25	
0.13	

72	
36	
70	
35	

> .95	
> .95	
> .95	
> .95	

1.15	
0.51	
1.15	
0.50	

1.60	
1.42	
1.64	
1.43	

< 10	
< 10	
< 10	
< 10	

50/10 	
50/10	
50/10 	
50/10	

12f	
12f	
12f	
12f	

-D
-D
-D
-D

B228PUNVDRH-D @ 100%	
			 120	
	 2 	 PRS		 B228PUNVDRH-D @ 50%	
B228PUNVDRH-D @ 100%	
			 277	
				 B228PUNVDRH-D @ 50%	

•	
•	
•	
•	

•	
•	
•	
•	

0.75	
0.38	
0.31	
0.17	

90	
45	
87	
44	

> .95	
> .95	
> .95	
> .95	

1.13	
0.51	
1.13	
0.51	

1.26	
1.13	
1.30	
1.16	

< 10	
< 10	
< 10	
< 10	

50/10 	
50/10	
50/10 	
50/10	

12f	
12f	
12f	
12f	

-D
-D
-D
-D

B128PUNVDRH-D
			 120	
	 1 	 PRS		 B128PUNVDRH-D
B128PUNVDRH-D
			 277	
				 B128PUNVDRH-D

@ 100%	
@ 50%	
@ 100%	
@ 50%	

•	
•	
•	
•	

•	
•	
•	
•	

0.25	
0.13	
0.12	
0.07	

28	
15	
28	
15	

> .99	
> .99	
> .94	
> .84	

1.15	
0.38	
1.15	
0.38	

4.11	
2.53	
4.11	
2.53	

< 10	
< 10	
< 10	
< 10	

50/10 	
50/10	
50/10 	
50/10	

12g	
12g	
12g	
12g	

-D
-D
-D
-D

B228PUNVDRH-D
			 120	
	 2 	 PRS		 B228PUNVDRH-D
B228PUNVDRH-D
			 277	
				 B228PUNVDRH-D

@ 100%	
@ 50%	
@ 100%	
@ 50%	

•	
•	
•	
•	

•	
•	
•	
•	

0.47	
0.23	
0.20	
0.11	

56	
28	
55	
28	

> .95	
> .95	
> .95	
> .90	

1.16	
0.51	
1.16	
0.51	

2.07	
1.82	
2.11	
1.82	

< 10	
< 10	
< 10	
< 10	

50/10 	
50/10	
50/10 	
50/10	

12f	
12f	
12f	
12f	

-D
-D
-D
-D

B228PUNVDRH-D
			 120	
	 2 	 PRS		 B228PUNVDRH-D
B228PUNVDRH-D
			 277	
				 B228PUNVDRH-D

@ 100%	
@ 50%	
@ 100%	
@ 50%	

•	
•	
•	
•	

•	
•	
•	
•	

0.34	
0.16	
0.15	
0.08	

40	
19	
40	
20	

> .95	
> .95	
> .95	
> .85	

1.17	
0.52	
1.17	
0.52	

2.93	
2.74	
2.93	
2.60	

< 10	
< 10	
< 10	
< 10	

50/10 	
50/10	
50/10 	
50/10	

12f	
12f	
12f	
12f	

-D
-D
-D
-D

B254PUNVDR-D @ 100%	
			 120	
	 2 	 PRS		 B254PUNVDR-D @ 50%	
B254PUNVDR-D @ 100%	
			 277	
				 B254PUNVDR-D @ 50%	

•	
•	
•	
•	

•	
•	
•	
•	

1.00	
0.50	
0.43	
0.22	

120	
60	
120	
60	

> .95	
> .95	
> .95	
> .90	

1.00	
0.45	
1.00	
0.45	

0.83	
0.75	
0.83	
0.75	

< 10	
< 10	
< 10	
< 10	

0/-18 	
0/-18	
0/-18 	
0/-18	

12f	
12f	
12f	
12f	

-D
-D
-D
-D

B254PUNVDR-D @ 100%	
			 120	
	 2 	 PRS		 B254PUNVDR-D @ 50%	
B254PUNVDR-D @ 100%	
			 277	
				 B254PUNVDR-D @ 50%	

•	
•	
•	
•	

•	
•	
•	
•	

0.90	
0.41	
0.39	
0.19	

108	
50	
106	
50	

> .95	
> .95	
> .95	
> .95	

1.06	
0.57	
1.06	
0.57	

0.98	
1.14	
1.00	
1.14	

< 10	
< 10	
< 10	
< 10	

0/-18 	
0/-18	
0/-18 	
0/-18	

12f	
12f	
12f	
12f	

-D
-D
-D
-D

B254PUNVDR-D
			 120	
	 2 	 PRS		 B254PUNVDR-D
B254PUNVDR-D
			 277	
				 B254PUNVDR-D

@ 100%	
@ 50%	
@ 100%	
@ 50%	

•	
•	
•	
•	

•	
•	
•	
•	

0.97	
0.47	
0.42	
0.21	

115	
57	
113	
57	

> .95	
> .95	
> .95	
> .95	

1.10	
0.63	
1.11	
0.63	

0.96	
1.11	
0.98	
1.11	

< 10	
< 10	
< 10	
< 10	

0/-18 	
0/-18	
0/-18 	
0/-18	

12f	
12f	
12f	
12f	

-D
-D
-D
-D

B254PUNVDR-D
			 120	
	 2 	 PRS		 B254PUNVDR-D
B254PUNVDR-D
			 277	
				 B254PUNVDR-D

@ 100%	
@ 50%	
@ 100%	
@ 50%	

•	
•	
•	
•	

•	
•	
•	
•	

0.88	
0.41	
0.38	
0.19	

106	
49	
104	
48	

> .95	
> .95	
> .95	
> .95	

1.04	
0.56	
1.04	
0.56	

0.98	
1.14	
1.00	
1.17	

< 10	
< 10	
< 10	
< 10	

0/-18 	
0/-18	
0/-18 	
0/-18	

12f	
12f	
12f	
12f	

-D
-D
-D
-D

B254PUNVDR-D @ 100%	
			 120	
	 2 	 PRS		 B254PUNVDR-D @ 50%	

•	
•	

•	
•	

0.88	
0.41	

106	
49	

> .95	
> .95	

1.04	
0.56	

0.98	
1.14	

< 10	
< 10	

0/-18 	
0/-18	

12f	
12f	

-D
-D

F28T5 - Two Lamp Applications

F35T5 - Two Lamp Applications

F21T5 - One Lamp Applications

F21T5 - Two Lamp Applications

F14T5 - Two Lamp Applications

F54T5HO - Two Lamp Applications

FT55W/2G11 - Two Lamp Applications

DEMANDflex

FT50W/2G11 - Two Lamp Applications

FC55T5-55W - Two Lamp Applications

F21T5-55W - One Lamp Application

See page 2-7 for Dimensions and Wiring Diagrams

PAGE 2-6

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

DEMANDflex
T8

DEMANDflex®
WIRING DIAGRAMS
Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances
Ballast case must be grounded. A star washer or other paint penetrating device is required.

Wiring Diagram 12a

Wiring Diagram 12e

Wiring Diagram 12b

Wiring Diagram 12f

Wiring Diagram 12c

Wiring Diagram 12g

Wiring Diagram 12d

Overall Dimensions
Draw #
L
9.50”
16.88”
16.88”

-A, -E

1.70”
1.18”
1.82”

Mounting Dimensions
H
M
X

1.18”
1.00”
1.18”

8.89”
16.20”
16.28”

1.69”
—
—

-D

FOR MORE INFORMATION CALL

PAGE 2-7

1-800-BALLAST
(225-5278)

DEMANDflex

-A
-D
-E

W

DCL Controls
DCL CONTROLS
MODEL
LP12DCLUNV-xx**
SC20DCLUNV**
MC20DCLUNV**
RSMDCL51
WTPDCL51∆
WPS5527K

DESCRIPTION
Circuit Control Panel
Single Circuit Controller
Open Style Single Circuit Controller
Contact Interface Controller
Time/Photo Controller
Photo Sensor for WTPDCL

LP12DCLUNV-xx
Dimensions	Mounting
Length	32”	 24”
Width	20”	 16”
Depth	4.3”
The same cabinet size is used
for the four different panels. the
quantity of individual controllers
installed is determined by the
model number.

xx = number of circuits (03 - 12)
* For additional lighting system controllers, contact Universal Lighting.
** Modbus versions of these controls are available.
∆ Consult Universal for configuration options.

SC20DCLUNV	

SC20DCLUNV
Single Circuit Controller

MOUNTING PATTERN

Dimensions
Length	9.66”
Width	3.98”
Depth	3.21”

MC20DCLUNV
Open Style,
Single Circuit Controller

Circuit control panels are used to send commands down the lighting circuit to the DemandFlex ballasts. The
LP12DCLUNV-xx panels are available with 3 to 12 integral circuit control modules. If more than 12 circuits are
being controlled, additional panels can be used.
The SC20DCLUNV is used when there are a small number of circuits or space limitations prevent the use of
an LP12DCLUNV panel.
One RSMDCL51 or WTPDCL51 can control up to 63 circuits. If more than 63 circuits are to be controlled, an
RSMDCL can be connected in parallel with either controller for another 63 circuits.

Contact Closure Interface Control

DCL Controls

Stand Alone Time Clock/Photo Cell Control

The WTPDCL51 controller provides time of day
scheduling and can also be connected to the
WPS5527K Photo Cell for daylight harvesting.
Manual override switches are also available.

The RSMDCL51 controller integrates with external
relays or switches to translate commands to the DCL
system. This controller can be used to interface with
building automation systems, PLC’s, or switches.
These systems may also incorporate photo cells for
dayllight harvesting.

Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances

FOR MORE INFORMATION CALL

PAGE 2-8

1-800-BALLAST
(225-5278)

Controllable Lighting
Fluorescent Energy
Management / Dimming
Ballasts and Controls
The effective dimming of fluorescent lights delivers a wide range
of benefits: greater control of workspace lighting, ability to create a mood, energy savings, and more.
Universal Lighting Technologies (“Universal”) line of electronic
dimming ballasts and controls lets you accomplish these goals
with a variety of products to suit your dimming needs. From
light level switching and analog dimming to digital dimming and
controls, Universal has the products and technologies to meet
today’s dimming requirements for energy savings and controllable lighting.

Fluorescent Dimming

Universal Lighting Technologies is a member of the Panasonic Group

Product Overview

Universal offers five different families of dimming products that can be used for today’s dimming
requirements for architectural lighting control and energy management applications:
BallaStar: Step-dimming
SuperDim: Analog (0 to 10 volt) dimming
DaliPRO: Digital dimming with the DALI protocol
DaliPRO Premium: Parallel-lamp digital dimming (DALI)
VariPRO: Parallel-lamp analog dimming
LevelPRO: Parallel-lamp step dimming

BallaStar® Light Level Switching (S30 & S50)

Our Ballastar® line offers two options of light level switching (either 100/50% or 100/60/30%).
That makes BallaStar® a cost-effective solution for both new construction and retrofits.
Universal BallaStar® ballasts are designed to ensure optimum lamp performance. Their Lamp Current
Crest Factors are well below the maximum 1.7 ANSI standard — and they start the lamps according to ANSI
recommendations at all dimming levels. Both of these important design parameters ensure optimum lamp
performance. In addition, BallaStar® ballasts actually increase cathode heating when dimming to maintain
the cathode’s proper temperature, which enhances lamp life and performance stability.

Fluorescent Dimming

• 1, 2, & 3 lamp models for 120 & 277 volt
• Switches to preset light levels, keeping all lamps illuminated
• Eliminates the dark spots associated with inboard/outboard configurations
• Connects with two line voltage power leads
– Wires the same as an inboard/outboard fixture
– No special controls required; uses two wall switches
• Meets all ASHRAE 90.1 and California Title 24 requirements for lighting control
• THD <10%
• Lower installed costs; less wiring and equipment required

Ballastar® Light Level Switching for ultimate control.

PAGE 2-10

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Product Overview

SuperDim® Analog Dimming Ballasts

Universal Lighting’s new SuperDim® analog dimming ballasts are a cost-effective choice for large scale
dimming applications. SuperDim® ballasts are designed for T8 and T5 linear fluorescent lamps and T4
4-pin quad and triple compact fluorescent lamps.
SuperDim® ballasts are compatible with a wide range of 0 – 10 volt controls and can be connected
to photocells for daylight harvesting. The resulting energy savings makes it easy to adhere to even
the strictest energy requirements, including California Title 24 and ASHRAE 90.1.
These versatile ballasts offer programmed rapid start technology for longer lamp life. They also
incorporate end-of-lamp-life shutdown circuits, low profile designs and < 10% THD at full bright.
Features and Benefits
• Ideal for T8 and T5 linear fluorescent lamps and T4 4-pin
quad and triple compact fluorescent lamps
• Compatible with most 0 – 10 volt manufactured controls
• Daylight harvesting options with photocells for maximum
energy savings
• Programmed rapid start technology maximizes lamp life
• Low profile design for fixture design flexibility
• End-of-lamp-life shutdown circuitry ensures safe operation
• < 10% THD at full bright
• Universal input voltage (120–277 volts) for installation flexibility

Fluorescent Dimming

PAGE 2-11

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Product Overview

DaliPROTM Digital Dimming Ballasts for DALI

DaliPROTM ballasts from Universal Lighting let you take full advantage of the Digital Addressable
Lighting Interface (DALI) standard...and that means greater flexibility, greater savings.
The DALI Advantage
The DALI protocol uses a 2-wire control loop to communicate with up to 64 ballasts. Broadcast,
group and individual addressing is used to control light levels, recall scenes and poll ballast status.
Many DALI-compatible controls are now available from established manufacturers; and new varieties
are being developed daily.
DaliPRO Features and Benefits
• Available for T8, T5, T5HO and compact fluorescent lamps
• Provides dimming down to 1% for linear lamps and 3% for compact fluorescent lamps
• Lets you adapt instantly to additions or changes in lighting design without ballast or fixture rewiring
• Offers status/performance data, including lamp status and system faults
• Low profile designs for easy installation in a wide variety of fixtures
• Universal input voltage (120– 277 volts)
– Installer-friendly; ensures you have the right ballast every time
– Reduces inventory costs and requirements
• End-of-Lamp Life Shutdown with auto reset circuitry for safe operation
• Programmed Rapid Start for long lamp life

Fluorescent Dimming

DaliPRO Premium
DaliPRO Premium performs the same as standard DaliPRO but with the additonal feature of parallel-lamp
operation.

PAGE 2-12

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Product Overview

VariPRO & LevelPRO Parallel-Lamp Dimming Ballasts
Universal Lighting Technologies’ parallel-lamp dimming families combine new performance features with maximum
energy savings. These ballasts provide parallel-lamp operation – when one lamp fails the other remains lit. This prevents
fixture from going dark and simplifies troubleshooting and maintenance operations.
Performance
• Total Harmonic Distortion (THD) < 10%
• Power Factor (PF) > 10%
• NEMA Premium
• RoHS Compliant

General Features and Benefits
• Quick Programmed Start Technology
– Start time less than 700ms
– Maintains long lamp life in frequently switched applications
• High Efficiency Operation
– Complies with CEE and NEMA Premium
– Incorporates Anti-Striation circuitry
– Designed for use with 30, 28, and 25 Watt energy saving lamps
• True Parallel-Lamp Operation
– When one lamp fails, other lamps continue to operate normally
– Simplifies fixture troubleshooting
• Universal Input Voltage and 347 Models

VariPRO Features and Benefits
• Analog (0-10V) Dimming Control
– Compatible with industry standard
0-10V controls and photocells
– Ideal for daylight harvesting

TM

LevelPRO Features and Benefits
• Line Voltage Step Dimming Control
– Uses standard wall switches
– Provides even fixture illumination

Fluorescent Dimming

PAGE 2-13

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Application And Operating Information
Although dimming ballasts follow similar installation and operating guidelines as electronic ballasts, application notes and
other training materials, written specifically for dimming ballasts, are provided on www.unvlt.com website.

SAFETY
Analog dimming ballasts are controlled by using a low voltage 0-10VDC control circuit. Care should be taken to insure that the
line voltage (AC) wires are not connected to the low voltage DC wires. SuperDim® Electronic dimming ballasts have a protection circuit that will sense if the ballast has been connected in this manner and not harm the ballast.
Light Level Switching Installation Note
The two power leads for the light level switching ballasts must be connected to the same power circuit. The leads should
connect to separate switches or relays for control of the light level switching operation. Connection of the input leads to separate power circuits can damage the ballasts.

Note:
Do not connect any other ballast to the load side of the switches controlling the switched
dimming ballast.
Compatible Dimming Controls
For a listing of compatible controls for universal analog ballasts, please consult catalog page 3-7, or call 1-800-BALLAST
or check out the Dimming and Controls section of our home page at www.unvlt.com.
Fusing
Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts.
For a comprehensive list of appropriate fuses, contact our Technical Engineering Services (TES) Department at 1-800-BALLAST.
Detailed Operating Instructions

Fluorescent Dimming

For additional information on all of Universal’s dimming products, consult our website at www.unvlt.com. Application notes,
dimming brochures and online training is available

PAGE 2-14

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Controls For Analog Dimming Ballasts
Manual Controls, Photo-Sensors, Wall Stations & Hand Held Remotes
Manufacturer

Website

Telephone

Cooper Controls

www.coopercontrol.com

(800) 553-3879

DimOnOff

www.dimonoff.com

(418) 682-3636

Douglas Lighting Controls, Inc

www.douglaslightingcontrol.com

(604) 873-2797

HUNT Dimming

www.huntdimming.com

(970) 484-9048

Lehigh Electric Products Co.

www.lehighdim.com

(610) 395-3386

Leviton

www.leviton.com/les

1-800-736-6682

Lutron

www.lutron.com/universal

(888) LUTRON1 - Sales
(800) 523-9466 - Technical Support

NexLight

www.nexlight.com

(218) 828-3700

The Watt Stopper, Inc

www.wattstopper.com

(800) 879-8585

Marlin Controls

www.marlincontrols.com

(800) 788-5750

Sensor Switch, Inc.

www.sensorswitch.com

(800) 727-7483
(800) PASSIVE

Touch-Plate Lighting Controls

www.touchplate.com

(260) 426-1565

Manufacturer

Website

Telephone

Cooper Controls

www.coopercontrol.com

(800) 553-3879

DimOnOff

www.dimonoff.com

(418) 682-3636

Douglas Lighting Controls, Inc

www.douglaslightingcontrol.com

(604) 873-2797

Lehigh Electric Products Co.

www.lehighdim.com

(610) 395-3386

Lutron

www.lutron.com/universal

(888) LUTRON1 - Sales
(800) 523-9466 - Technical Support

NexLight

www.nexlight.com

(218) 828-3700

Marlin Controls

www.marlincontrols.com

(800) 788-5750

Sensor Switch, Inc.

www.sensorswitch.com

(800) 727-7483
(800) PASSIVE

Touch-Plate Lighting Controls

www.touchplate.com

(260) 426-1565

Occupancy Sensors

Systems: Control Panels, Building Management Systems, etc
Website

Telephone

DimOnOff

www.dimonoff.com

(418) 682-3636

Douglas Lighting Controls, Inc

www.douglaslightingcontrol.com

(604) 873-2797

Cooper Controls

www.coopercontrol.com

(800) 553-3879

HUNT Dimming

www.huntdimming.com

(970) 484-9048

Lehigh Electric Products Co.

www.lehighdim.com

(610) 395-3386

Leviton

www.leviton.com/les

1-800-736-6682

Lutron

www.lutron.com/universal

(888) LUTRON1 - Sales
(800) 523-9466 - Technical Support

NexLight

www.nexlight.com

(218) 828-3700

The Watt Stopper, Inc

www.wattstopper.com

(800) 879-8585

Marlin Controls

www.marlincontrols.com

(800) 788-5750

Touch-Plate Lighting Controls

www.touchplate.com

(260) 426-1565

The information listed above is provided by Universal Lighting Technologies to facilitate development of dimming systems. All information has been provided by the controls manufacturers, and Universal
Lighting Technologies makes no guarantee regarding its accuracy. The reader is advised to contact these, and other manufacturers of analog dimming systems, to obtain application advice, to determine
availability of the controls listed above, and to learn about other controls that may be offered.
Data is subject to change without notice.

PAGE 2-15

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent Dimming

Manufacturer

DaliPRO® DIMMING BALLASTS

DaliPRO®

	 Lamp	
		
Starting	
	 Qty.	 Method 	
F1728
1
PRS
2
PRS
F32T8 *
1
PRS
2
PRS
F14T5
1
PRS
2
PRS
F21T5
1
PRS

Fluorescent Dimming

2
PRS
F28T5 *
1
PRS

		
Line	
Catalog	
Volts	
Number	

PRS

2

PRS

Dim.

<10%

32/0

1

-A

2.69

<10%

32/0

2

-A

1.00

2.90

<10%

32/0

1

-A

1.00

1.52

<10%

32/0

2

-A

>.95

1.00

5.61

<10%

50/10

1

-D

>.95

1.00

3.02

<10%

50/10

2

-D

25
24
45
45

>.95

1.00

4.15

<10%

50/10

1

-D

>.95

1.00

3.02

<10%

50/10

2

-D

32
32
62
61

>.95

1.00

3.13

<10%

50/10

1

-D

B228PUNVDV3-D

0.29
0.13
0.52
0.22

>.95

1.00

1.64

<10%

50/10

2

-D

B135PUNVDV3-D

0.35
0.15

41
41

>.95

1.00

2.45

<10%

50/10

1

-D

C213UNVDV3ME

0.15
0.07
0.27
0.12

18
18
32
32

>.90

1.00

5.56

<15%

32/0

3

-ME

>.95

1.00

3.17

<15%

32/0

4

-ME

0.20
0.09
0.35
0.15

23
22
45
43

>.90

1.00

4.55

<10%

32/0

3

-ME

>.95

1.00

2.36

<10%

32/0

4

-ME

0.25
0.11
0.44
0.19

31
29
51
50

>.95

1.00

2.00

<10%

32/0

3

-ME

>.95

1.00

3.52

<10%

32/0

4

-ME

0.26
0.12
0.58
0.26

32
33
71
70

>.95

1.00

<10%

32/0

3

-ME

>.95

1.00

3.10
1.41
1.43

<10%

0/-18

4

DP2

0.43
0.19
0.82
0.36

47
45
92
91

>.95

1.00

<10%

0/-18

3

DP2

>.95

1.00

<10%

0/-18

4

DP2

0.37
0.16
0.83
0.37

45
44
97
94

>.95

1.00

<10%

0/-18

5

DP1

>.95

1.00

<10%

0/-18

6

DP1

120
277
120
277

B132PUNVDV3-A

120
277
120
277

B114PUNVDV3-D

B232PUNVDV3-A

B232PUNVDV3-A

B214PUNVDV3-D

120
277
120
277

B128PUNVDV3-D

120
277
120
277

B128PUNVDV3-D

CFTR42W/G24q
120
1
PRS
277
120
2
PRS
277
1

Wiring	
Diag.	

B132PUNVDV3-A

2
PRS
F35T5
120
1
277
CFQ13W/G24q
120
1
PRS
277
120
2
PRS
277
CFQ18W/G24q
120
1
PRS
277
120
2
PRS
277
CFQ26W/G24q
120
1
PRS
277
120
2
PRS
277
CFTR32W/G24q
120
1
PRS
277
120
2
PRS
277

FT40W/2G11

Min. F/C	
Start	
Temp	

120
277
120
277

120
277
120
277

B228PUNVDV3-D

C213UNVDV3ME
C218UNVDV3ME
C218UNVDV3ME
C226UNVDV3ME
C226UNVDV3ME
C226UNVDV3ME
C232PUNVDV3
C226UNVDV3ME
C242PUNVDV3
C140PUNVDV3
C240PUNVDV3

Line	
Current	
(Amps)	

Input	
Power	
(Watts)	

Power	
Factor	
(PF)	

Ballast	
Factor	
(BF)	

0.18
0.08
0.33
0.14

21
20
38
38

>.95

1.02

5.10

>.98

1.01

0.30
0.13
0.58
0.25

35
35
67
66

>.95
>.98

0.15
0.07
0.28
0.13

18
18
33
33

0.23
0.10
0.40
0.17

* Consult Specification Sheets at www.unvlt.com for additional lamp applications

Ballast		
Efficacy	
THD	
Factor (BEF)	
%	

2.13
2.22
1.09
1.10
2.22
2.27
1.03
1.06

See page 2-22­­­­ for Dimensions
and Wiring Diagrams

STARTING METHOD LEGEND
PAR-PRS = Parallel Programmed Start

PAGE 2-­16

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

DaliPRO® Premium DIMMING BALLASTS

DaliPRO®
Premium

PARALLEL LAMP

DIMMING

	 Lamp	
		
Starting	
	 Qty.	 Method 	
F1728
1
PRS

		
Line	
Catalog	
Volts	
Number	

Min. F/C	
Start	
Temp	

Wiring	
Diag.	

Dim.

<10%

32/0

20

-A

5.13
5.13
5.13
2.84

<10%
<20%
<20%
<10%

32/0
32/0
32/0
32/0

20
20
20
2

-D
-A
-D
-A

1.02
1.00
1.00

2.84
2.78
2.78

<10%
<10%
<10%

32/0
32/0
32/0

2
2
2

-D
-A
-D

>.98

1.00

2.80

<10%

32/0

20

-A

>.98
>.95
>.95
>.99

1.00
1.00
1.00
1.00

2.85
2.87
2.87
1.53

<10%
<10%
<10%
<10%

32/0
32/0
32/0
32/0

20
20
20
2

-D
-A
-D
-A

>.99
>.95
>.95

1.00
1.00
1.00

1.53
1.54
1.54

<10%
<10%
<10%

32/0
32/0
32/0

2
2
2

-D
-A
-D

19
19
19
19
19
19
35
35
35
35
35
35

>.95

1.01

5.19

<10%

50/10

20

-A

>.95
>.90
>.90
>.98

1.01
1.01
1.01
1.01

5.19
5.27
5.27
2.92

<10%
<20%
<10%
<10%

50/10
50/10
50/10
50/10

20
20
20
2

-D
-A
-D
-A

>.98
>.95
>.95

1.01
1.01
1.01

2.92
2.93
2.93

<10%
<10%
<10%

50/10
50/10
50/10

2
2
2

-D
-A
-D

35
34
35
34
34
34
62
61
62
61
64
64

>.98

1.00

2.95

<10%

50/10

20

-A

>.98
>.95
>.95
>.99

1.00
1.00
1.00
1.00

2.95
2.94
2.94
1.63

<10%
<10%
<10%
<10%

50/10
50/10
50/10
50/10

20
20
20
2

-D
-A
-D
-A

B228PUDV3PLD
B228P3DV3PLA
B228P3DV3PLD

0.30
0.13
0.29
0.12
0.10
0.10
0.56
0.24
0.56
0.24
0.19
0.19

>.99
>.98
>.98

1.00
1.00
1.00

1.63
1.57
1.57

<10%
<10%
<10%

50/10
50/10
50/10

2
2
2

-D
-A
-D

B254PUDV3PLD
B254P3DV3PLD
B254PUDV3PLD
B254P3DV3PLD

0.51
0.23
0.18
0.94
0.41
0.33

54
56
58
116
112
109

>.97
>.98
>.99
>.99

1.00
1.00
1.00
1.00

1.85
1.72
0.89
0.92

<10%
<10%
<10%
<10%

32/0
32/0
32/0
32/0

20
20
2
2

-D
-D
-D
-D

B232PUDV3PLA
B232PUDV3PLD
B232P3DV3PLA
B232P3DV3PLD
B232PUDV3PLA
B232PUDV3PLD
B232P3DV3PLA
B232P3DV3PLD
B232PUDV3PLA
B232PUDV3PLD
B232P3DV3PLA
B232P3DV3PLD
B232PUDV3PLA
B232PUDV3PLD
B232P3DV3PLA
B232P3DV3PLD
B228PUDV3PLA
B228PUDV3PLD
B228P3DV3PLA
B228P3DV3PLD
B228PUDV3PLA
B228PUDV3PLD
B228P3DV3PLA
B228P3DV3PLD
B228PUDV3PLA
B228PUDV3PLD
B228P3DV3PLA
B228P3DV3PLD
B228PUDV3PLA

Input	
Power	
(Watts)	

Power	
Factor	
(PF)	

Ballast	
Factor	
(BF)	

0.19
0.08
0.19
0.08
0.07
0.07
0.32
0.14
0.32
0.14
0.11
0.11

20
20
20
20
20
20
37
36
37
36
37
37

>.95

1.02

5.13

>.95
>.95
>.95
>.98

1.02
1.04
1.04
1.02

>.98
>.95
>.95

0.30
0.13
0.31
0.13
0.11
0.11
0.58
0.25
0.58
0.25
0.19
0.19

36
35
36
35
35
35
67
65
67
65
65
65

0.16
0.07
0.16
0.07
0.06
0.06
0.29
0.13
0.29
0.13
0.10
0.10

* Consult Specification Sheets at www.unvlt.com for additional lamp applications

Ballast		
Efficacy	
THD	
Factor (BEF)	
%	

See page 2-22­­­­ for Dimensions
and Wiring Diagrams

STARTING METHOD LEGEND
PAR-PRS = Parallel Programmed Start

PAGE 2-­17

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent Dimming

120
277
120
1
PRS
277
1
PRS
347
1
PRS
347
120
2
PRS
277
120
2
PRS
277
2
PRS
347
2
PRS
347
F32T8* (also operates F28T8)
120
1
PRS
277
120
1
PRS
277
1
PRS
347
1
PRS
347
120
2
PRS
277
120
2
PRS
277
2
PRS
347
2
PRS
347
F14T5 (also operates F21T5)
120
1
PRS
277
120
1
PRS
277
1
PRS
347
1
PRS
347
120
2
PRS
277
120
2
PRS
277
2
PRS
347
2
PRS
347
F28T5 (also operates F28T5/ES)
120
1
PRS
277
120
1
PRS
277
1
PRS
347
1
PRS
347
120
1
PRS
277
120
1
PRS
277
1
PRS
347
1
PRS
347
F54T5HO*
120
1
PRS
277
1
PRS
347
120
2
PRS
277
2
PRS
347

Line	
Current	
(Amps)	

SuperDim®

SuperDim® 0-10V DIMMING BALLASTS

0-10V
DIMMING

Please visit www.unvlt.com for the most up to date status
and recent changes to the SuperDim product family.

Fluorescent Dimming

Lamp				
	
		 Starting	 Line	
Catalog	
Qty.	 Method	 Volts	
Number	
F17T8
	
	120	
1	PRS
B132PUNVSV3-A	
			
277		
	
	120	
2	PRS
B232PUNVSV3-A	
			
277		
F25T8
	
	120	
1	PRS
B132PUNVSV3-A	
			
277		
	
	120	
2	PRS
B232PUNVSV3-A	
			
277		

F32T8
	
	120	
1	PRS
B132PUNVSV3-A	
			
277		
	
	120	
2	PRS
B232PUNVSV3-A	
			
277		
F14T5
	
	120	
1	PRS
B114PUNVSV3-D	
			
277		
	
	120	
2	PRS
B214PUNVSV3-D	
			
277		
F21T5
	
	120	
1	PRS
B128PUNVSV3-D	
			
277		
	
	120	
2	PRS
B228PUNVSV3-D	
			
277		
F28T5
	
	120	
1	PRS
B128PUNVSV3-D	
			
277		
	
	120	
2	PRS
B228PUNVSV3-D	
			
277		
F35T5
	
	120	
1	PRS
B135PUNVSV3-D	
			
277		
CFQ13W/G24q & CFTR13W/Gx24q
	
	120	
1	PRS
C213UNVSV3ME	
			
277		
	
	120	
2	PRS
C213UNVSV3ME	
			
277		
CFQ18W/G24q & CFTR18W/Gx24q
	
	120	
1	PRS
C218UNVSV3ME	
			
277		
	
	120	
2	PRS
C218UNVSV3ME	
			
277		
CFQ26W/G24q & CFTR26W/Gx24q
	
	120	
1	PRS
C226UNVSV3ME	
			
277		
	
	120	
2	PRS
C226UNVSV3ME	
			
277		
CFTR32W/Gx24q
	
	120	
1	PRS
C226UNVSV3ME	
			
277		
CFTR42W/Gx24q
	
	120	
1	PRS
C226UNVSV3ME	
			
277		

Line	
Input	 Power	 Ballast		
Min. F/C	
Current	 Power	 Factor	 Factor	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	
%	
Temp	
Diag.	
Dim.
0.13	16	 	
	
> .97
0.85
0.06	 16		
0.27	32	 	
	
> .98
0.85
0.12	
32 			
0.18	22	 	
	
> .98
0.85
0.08	 22			
0.38	45	 	
	
> .99
0.85
0.16	 44			
0.25	
0.11	
0.48	
0.20	

30	
	
	
> .99
0.88
30		
57	
	
	
> .99
0.88
56			

0.14	
0.06	
0.27	
0.11	

17	
	
	
> .97
1.00
17			
32	
	
	
1.00
32	 > .97

0.27	
0.12	
0.39	
0.17	

25	
	
> .95
25
47	
	
46	 > .95

0.21	
0.10	
0.53	
0.22	

32	
	
	
> .99
1.00
32			
63	
	
	
> .99
1.00
61			

<10	50/10	 7	 -A
<10	50/10	 8	 -A
<10	32/0	 7	-D
<10	32/0	 8	-D

<10	50/10	 7	 -D
<10	50/10	 8	 -D
<10	50/10	 7	 -D
<15	 32/0	 9	C11
<10	 32/0	 10	C11

1.00	<10	 32/0	 10	C11

34	
	
> .97
34		

1.00

0.35	42	 	
0.15	 42	 > .98

1.00

STARTING METHOD LEGEND
PRS = Programmed Rapid Start

<10	50/10	 8	 -A

1.00	<10	 32/0	 9	 C11

0.26	28	 	
	
> .96
1.00
0.10	 28			
0.44	53	 	
	
> .99
1.00
0.19	 53			
0.28	
0.12	

<10	50/10	 7	 -A

1.01	<10	 50/10	 8	 -D

0.13	16	 	
	
> .99
1.00
0.06	 30			
0.25	16	 	
	
> .99
1.00
0.11	 30			
20	
	
20	 > .99
39	
	
38	 > .99

<10	50/10	 8	 -A

1.01	<10	 50/10	 7	 -D

0.33	40	 	
	
> .99
1.00
0.14	 39			

0.17	
0.08	
0.33	
0.15	

<10	50/10	 7	 -A

	
	

<10	 32/0	 9	C11
<10	 32/0	 10	C11
<10	 32/0	 9	C11
<10	 32/0	 9	C11

See page 2-22 for Dimensions
and Wiring Diagrams

PAGE 2-­18

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

BallaSTAR 0-10 VOLT
DIMMING BALLASTS
®

BallaStar®

• Analog Dimming
• Rapid Start
• 1, 2, 3 & 4 Lamp Applications

0-10V
DIMMING

T8 Straight Lamps

FOR (1), (2), (3) & (4) T8 LAMPS
Please visit www.unvlt.com for the most up to date status
and recent changes to the Ballastar 0-10V product family.

T12 U-Shaped Lamps

		
	 Lamp	 				
	
		 Starting	 Line	
Catalog					
	 Qty.	 Method	
Volts	
Number					
F25T8 - One Lamp Applications
	
	
	
B132R347V5 @ 100%			
1	
347
				
B132R347V5 @ 5%			
F32T8 - One Lamp Applications
	 		
	
B132R347V5 @ 100%			
1
347
				
B132R347V5 @ 5%			
F32T8 - Two Lamp Applications
			
	
B232SR347V5 @ 100%			
347
				
B232SR347V5 @ 5%			
2	RS
	
B232SR347V5 	@ 100%			
	347	
				
B232SR347V5 @ 5% 			
F32T8 - Three Lamp Applications
	
B332SR120V5 	 @ 100%			
			
120
	
		
B332SR120V5 	 @ 5%			
3	SER-RS
	 		
	
B332SR277V5	 @ 100%			
277
				
B332SR277V5 	 @ 5%			
F32T8 - Four Lamp Applications
	
	
B432SR277V5 @ 100%			
4	SER/PAR-RS 	277
				
B432SR277V5 @ 5%			

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	Factor	Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	 Factor (BEF)	 %	
Temp	 Diag.	 Dim.
0.08	
0.02	

26	
7	

> .99	
> .90	

0.90	
0.05	

3.46	
0.71	

< 10	
< 30	

50/10	
50/10	

7	
7	

ST
ST

0.09	
0.02	

32	
8	

> .99	
> .90	

0.88	
0.05	

2.75	
0.63	

< 10	
< 20	

50/10	
50/10	

7	
7	

ST
ST

0.18	
0.04	
0.18	
0.04	

62	
13	
62	
13	

> .99	
> .90	
> .99	
> .90	

0.88	
0.05	
0.88	
0.05	

1.42	
0.38	
1.42	
0.38	

< 10	
< 15	
<10	
<15	

50/10	
50/10	
50/10	
50/10	

8	
8	
8	
8	

ST
ST
ST
ST

0.77	
0.17	
0.33	
0.07	

92	
20	
92	
20	

> .99	
> .90	
> .99	
> .90	

0.88	
0.05	
0.88	
0.05	

0.96	
0.25	
0.96	
0.25	

< 10	
< 10	
< 10	
< 15	

50/10 	
50/10 	
50/10 	
50/10 	

17	
17	
17	
17	

ST
ST
ST
ST

0.42	
0.11	

117	
27	

> .99	
> .90	

0.88	
0.05	

0.79	
0.19	

< 10	
< 15	

50/10 	
50/10	

16	
16	

-ZZ
-ZZ

IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start

See page 2-22 for Dimensions
and Wiring Diagrams
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start

PAGE 2-­19

PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent Dimming

All models except B232SR347V5 are cULus Listed
B232SR347V5 is CSA Certified		

BALLASTAR
LIGHT LEVEL
SWITCHING

BallaSTAR® STEP DIMMING BALLASTS
FOR (1), (2) & (3) T8 LAMPS

• Step Dimming
•R
 apid Start
T8 Straight Lamps

• 1 -3 Lamp Applications

Fluorescent Dimming

T12 U-Shaped Lamps

		
	 Lamp	 				
	
		 Starting	 Line	
Catalog					
	 Qty.	 Method	
Volts	
Number					
F17T8 - One Lamp Applications
B232PUS50-A @ 100%			
			
120	
	
		
B232PUS50-A @ 50%			
1	PRS
B232PUS50-A @ 100%			
			
277	
				
B232PUS50-A @ 50%			
F17T8 - Two Lamp Applications
B232PUS50-A @ 100%			
			
120	
	 	
		
B232PUS50-A @ 50%			
2
PRS
B232PUS50-A @ 100%			
			
277	
				
B232PUS50-A @ 50%			
F25T8 - One Lamp Applications
	
	
	
B232PUS50-A @ 100%			
	
120
	
		
B232PUS50-A @ 50%			
1	RS
			
	
B232PUS50-A @ 100%			
277
				
B232PUS50-A @ 50%			
F25T8 - Two Lamp Applications
	
	
	
B232PUS50-A @ 100%			
	
120
	
		
B232PUS50-A @ 50%			
2	SER-RS
	
	
	
B232PUS50-A @ 100%			
	
277
				
B232PUS50-A @ 50%			
F32T8 - One Lamp Applications
	
	
B232PUS50-A @ 100%			
1	RS	 120
				
B232PUS50-A @ 50%			
	 		
	
B232PUS50-A @ 100%			
277
				
B232PUS50-A @ 50%			
F32T8 - Two Lamp Applicationswa
	 			
B232SR120S30 @ 100%			
			
120	
B232SR120S30 @ 60%			
				
B232SR120S30 @ 30%			
	 			
B232SR277S30 @ 100%			
	
	 277	
B232SR277S30 @ 60%			
2	SER-RS
				
B232SR277S30 @ 30%			
	
	
	
B232PUS50-A @ 100%			
	
120
				
B232PUS50-A @ 50%			
	 		
	
B232PUS50-A @ 100%			
277
				
B232PUS50-A @ 50%			
F32T8 - Three Lamp Applications
				
B332SR120S30	@ 100%			
			
120	
B332SR120S30 	@ 60%			
	
		
B332SR120S30	@ 30%			
3	SER-RS
	 		
B332SR277S30 	@ 100%			
	
			
277	
B332SR277S30 	@ 60%			
				
B332SR277S30 	@ 30%			
All models are cULus Listed	

Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
Current	 Power	Factor	Factor	 Efficacy	 THD	 Start	 Wiring	
(Amps)	 (Watts)	 (PF)	
(BF)	 Factor (BEF)	 %	
Temp	 Diag.	 Dim.
0.14	
0.08	
0.08	
0.05	

16	
9	
16	
9	

> .95	
> .95	
> .70	
> .70	

0.88	
0.29	
0.88	
0.29	

5.50	
3.22	
5.50	
3.22	

< 15	
< 15	
< 15	
< 15	

32/0 	
32/0	
32/0 	
32/0	

11	
11	
11	
11	

-A
-A
-A
-A

0.25	
0.14	
0.12	
0.07	

30	
16	
30	
16	

> .99	
> .98	
> .88	
> .85	

0.87	
0.30	
0.87	
0.30	

2.90	
1.88	
2.90	
1.88	

< 10	
< 15	
< 10	
< 15	

32/0 	
32/0	
32/0 	
32/0	

12	
12	
12	
12	

-A
-A
-A
-A

0.21	
0.10	
0.11	
0.06	

24	
12	
24	
12	

> .95	
> .90	
> .80	
> .80	

0.85	
0.28	
0.85	
0.28	

3.54	
2.33	
3.54	
2.33	

< 10	
< 10	
< 10	
< 10	

32/0 	
32/0	
32/0 	
32/0	

11	
11	
11	
11	

-A
-A
-A
-A

0.39	
0.20	
0.18	
0.09	

46	
24	
46	
24	

> .98	
> .95	
> .98	
> .90	

0.84	
0.28	
0.84	
0.28	

1.83	
1.17	
1.83	
1.17	

< 10	
< 10	
< 10	
< 10	

32/0 	
32/0	
32/0 	
32/0	

12	
12	
12	
12	

-A
-A
-A
-A

0.25	
0.12	
0.12	
0.06	

29	
14	
29	
14	

> .99	
> .98	
> .85	
> .80	

0.88	
0.29	
0.88	
0.29	

3.03	
2.07	
3.03	
2.07	

< 10	
< 10	
< 10	
< 20	

32/0 	
32/0	
32/0 	
32/0	

11	
11	
11	
11	

-A
-A
-A
-A

0.52	
0.38	
0.24	
0.23	
0.17	
0.11	
0.48	
0.24	
0.21	
0.11	

62	
45	
28	
62	
45	
28	
57	
28	
56	
28	

> .99	
> .95	
> .95	
> .99	
> .95	
> .95	
> .99	
> .99	
> .95	
> .90	

0.88	
0.58	
0.27	
0.88	
0.58	
0.27	
0.88	
0.30	
0.88	
0.30	

1.42	
1.29	
0.96	
1.42	
1.29	
0.96	
1.54	
1.07	
1.57	
1.07	

< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	
< 10	

50/10 	
50/10	
50/10	
50/10 	
50/10	
50/10	
32/0 	
32/0	
32/0 	
32/0	

12	
12	
12	
12	
12	
12	
12	
12	
12	
12	

ST
ST
ST
ST
ST
ST
-A
-A
-A
-A

0.78	
0.61	
0.40	
0.34	
0.26	
0.16	

93	
69	
43	
94	
69	
43	

> .99	
> .95	
> .95	
> .99	
> .95	
> .95	

0.88	
0.60	
0.30	
0.88	
0.60	
0.30	

0.95	
0.87	
0.70	
0.94	
0.87	
0.70	

< 10	
< 10	
< 10	
< 10	
< 10	
< 10	

50/10 	
50/10 	
50/10 	
50/10 	
50/10 	
50/10 	

15	
15	
15	
15	
15	
15	

ST
ST
ST
ST
ST
ST

See page 2-22 for Dimensions and Wiring Diagrams

PAGE 2-20

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

BallaSTAR® STEP DIMMING BALLASTS
FOR T5 LAMPS

BALLASTAR

• Step Dimming
• Programmed Rapid Start
• 2 Lamp Applications

LIGHT LEVEL
SWITCHING

T5 Straight Lamps

All models are cULus Listed	

IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start

See page 2-22 for Dimensions and Wiring Diagrams

STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start

PAGE 2-21

PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent Dimming

	 	
	 Lamp	 				
	
Line	
Input	 Power	 Ballast	
Ballast		
Min. F/C	
		 Starting	 Line	
Catalog					 Current	 Power	Factor	Factor	 Efficacy	 THD	 Start	 Wiring	
	 Qty.	 Method	
Volts	
Number					 (Amps)	 (Watts)	 (PF)	
(BF)	 Factor (BEF)	 %	
Temp	 Diag.	 Dim.
F14T5 - Lamp Applications
	
	
	
B214PU115S50A @ 100%			
0.17	
21	 > .95	 1.19	
5.90	
< 15	 50/10 	 11	
-A
	
120
	 1	
PRS		
B214PU115S50A @ 50%			
0.09	
10	 > .95	 0.40	
3.74	
< 15	 50/10	
11	
-A
	 		
	
B214PU115S50A @ 100%			
0.09	
21	 > .75	 1.19	
5.80	
< 15	 50/10 	 11	
-A
277
				
B214PU115S50A @ 50%			
0.05	
10	 > .75	 0.40	
3.50	
< 15	 50/10	
11	
-A
	
	
	
B214PU115S50A @ 100%			
0.33	 37.5	 > .95	 1.15	
3.10	
< 10	 50/10 	 12	
-A
	
120
	 2	
PRS		
B214PU115S50A @ 50%			
0.15	
18	 > .95	 0.40	
2.19	
< 15	 50/10	
12	
-A
	 		
	
B214PU115S50A @ 100%			
0.15	
37	 > .90	 1.15	
3.11	
< 10	 50/10 	 12	
-A
277
				
B214PU115S50A @ 50%			
0.08	
19	 > .85	 0.40	
2.14	
< 15	 50/10	
12	
-A
		
	
B228PU95S50D @ 100%			
0.29	
35	 > .95	 1.00	
2.86	
< 10	 50/10 	 14	 -D
	120
	 2	
PRS		
B228PU95S50D @ 50%			
0.13	
16	 > .95	 0.37	
2.30	
< 10	 50/10	
14	 -D
		
	
B228PU95S50D @ 100%			
0.13	
35	 > .95	 1.00	
2.86	
< 10	 50/10	
14	 -D
	
277
				
B228PU95S50D @ 50%			
0.06	
16	 > .90	 0.37	
2.29	
< 10	 50/10	
14	 -D
F21T5 - Lamp Applications
	
	
	
B214PU115S50A @ 100%			
0.24	
29	 > .95	 1.18	
4.09	
< 10	 50/10 	 11	
-A
	
120
	 1	
PRS		
B214PU115S50A @ 50%			
0.12	
14	 > .95	 0.39	
2.84	
< 15	 50/10	
11	
-A
	 		
	
B214PU115S50A @ 100%			
0.12	
29	 > .85	 1.18	
4.06	
< 15	 50/10 	 11	
-A
277
				
B214PU115S50A @ 50%			
0.62	
14	 > .85	 0.40	
2.75	
< 15	 50/10	
11	
-A
	
	
	
B228PU95S50D @ 100%			
0.40	
48	 > .95	 0.99	
2.06	
< 10	 50/10 	 14	 -D
	
120
	 2	
PRS		
B228PU95S50D @ 50%			
0.18	
21	 > .95	 0.36	
1.73	
< 10 	 50/10	
14	 -D
	 		
	
B228PU95S50D @ 100%			
0.17	
47	 > .95	 0.99	
2.10	
< 10 	 50/10 	 14	 -D
277
				
B228PU95S50D @ 50%			
0.08	
22	 > .95	 0.36	
1.65	
< 10 	 50/10	
14	 -D
F28T5 - Lamp Applications
	
	
	
B214PU115S50A @ 100%			
0.32	
38	 > .95	 1.15	
3.02	
< 10	
	
	
120
50/10
11	-A
	 1	
PRS		
B214PU115S50A @ 50%			
0.16	
19	 > .95	 0.45	
2.37	
< 15			
	
B214PU115S50A @ 100%			
0.15	
38	 > .90	 1.15	
3.07	
< 10	
	 		
	
277
50/10
11	-A
				
B214PU115S50A @ 50%			
0.08	
19	 > .85	 0.43	
2.23	
< 15			
	
	
B228PU95S50D @100%	
0.50	
58	 > .99	 0.95	
1.64	
< 10	
	
	
120
50/10	 14	-D
	
				
B228PU95S50D @50%			
0.23	
28	 > .99	 0.35	
1.25	
< 20	
2	PRS
	
B228PU95S50D @100%	
0.21	
57	 > .98	 0.95	
1.67	
< 10	
			
	
277
50/10	 14	-D
	
				
B228PU95S50D @50%			
0.10	
28	 > .95	 0.35	
1.25	
< 20	
	
	
B228PU115S50D @100%	
0.59	
71	 > .99	 1.15	
1.62	
< 10	
	
	
120
50/10	 14	-D
	
				
B228PU115S50D @50%			
0.29	
34	 > .99	 0.45	
1.32	
< 10
2	PRS
			
	
B228PU115S50D @100%	
0.25	
69	 > .98	 1.15	
1.67	
< 10	
	
277
50/10	 14	-D
	
				
B228PU115S50D @50%			
0.12	
34	 > .95	 0.45	
1.32	
< 15	
º Preliminary Data

Black (hot)

Black (hot)

L
N

White (neutral)

Red
Red

L
N

White (neutral)

Red
Red

DIMENSIONS
& WIRING

Violet (control)

Violet (control)

DA

Blue

DA

Blue

Black (hot)

Line S1
S2

L
N

White (neutral)

Red
Red

L
N

White (neutral)

Red
Red

Violet (control)

Violet (control)

	 Overall Dimensions	
	Draw #	
L	
	-A	
	-D	
	-C11	
	ST	
	-ZZ	
	DP1	
	DP2	

DA

Blue

DA

Blue

9.50”	 1.70”	
16.88”	 1.18”	
4.94”	
3.00”	
9.50”	 2.40”	
16.40”	 2.40”	
18.00”	 1.18”	
4.95”	Black (hot)2.93”	

5

L
N

White (neutral)

1.18”	
1.00”	
1.00”	
1.55”	
1.50”	
1.18”	
1.38”	
Red
Red

Violet (control)

DA

Blue

DA

Blue

5

Black
Blk/Wht
White

Neutral
Line S1
Black (hot)
S2
White
(neutral)
S1
Line
Neutral

8.89”	 —
16.20”	 —
4.61”	
—
8.89”	 1.69”
15.88”	 1.69”
17.70”	
—
4.57”	
—

Blue

DA

Line S1
S2

S2

Blue
Red
Red

Black
L
Blk/Wht

Red
Red

Ballast
Ballast
Ballast

White

Neutral

DA

Violet (control)

Yel
Red
Yel
Red
Red
Blue
Yel
Red
Blue
Yel
Yel
Blue
Yel
Blue
Blue

Ballast

NBlack
White
Blk/Wht

Violet (control)

Blue

DA

Blue

6

Black (hot)
S1
White
Line (neutral)
S2

L
Black
N
Blk/Wht

11
11
11

Red
Red

Ballast

7

Red
DIAGRAM
6
Red

7
Black (hot)
White (neutral)

Red
Red

Ballast

Black (hot)

Fluorescent Dimming

7

L
N

Line S1
Black (hot)S2

L
N

-A, ST, -ZZ

White
Violet (control
+)(neutral)
(+)
Gray (control -)
(-)

Red
Red

Blue
Blue

C11, DP2

Ballast

Violet (control +)
Gray (control -)

WIRING DIAGRAMS

(+)
(-)

Violet (control +)
Gray (control -)

Black (hot)
L
White (neutral)Violet (control)
N (control)
Violet

1

L
N

DA

2

Black (hot) Black (hot)
L
White (neutral)
White (neutral)
N

Red
Red

Blue

Ballast
Violet (control)
Violet (control)

2

DIAGRAM 1

DA
DA

Blue
Blue

Black (hot)
White (neutral)

L
N

2

Violet
(control)
Black
(hot)
L
Violet (control)
White (neutral)
N

Violet (control)
Violet (control)

Red
Red

Yel

Ballast

Black (hot)
DA
Red Blue
White
DA
Blue
Violet (control
+)(neutral)
Red
(+)
Gray (control -)
(-)
Yel
Ballast Yel

L
N

3

DIAGRAM 2

Violet (control +)
DA
Blue
Black (hot)Gray
L (control -)
DA White (neutral) Blue
N

Black (hot)
L
White (neutral)Violet (control)
N (control)
Violet

(+)
(-)

Red
Red

Ballast
Blue

Red

DA

Yel
Yel
Blue

Red
Red

Blue

Yel

Ballast

Red
DA

Violet (control)

Blue

Blue

DA

Red
Red

Ballast

Yel
Yel

Violet
(control)
Black
(hot)
L
Violet (control)
White (neutral)
N

4

Red
Red

5

L

Yel
Red

Blue
Blue

N

Blue
Blue

Black (hot)Gray (control -)
L
White (neutral)
N

4

Red

Red
Red

DA
DIAGRAM
4
DA

Violet (control)

6

DA
DA

Black (hot)
White (neutral)

Blue
Blue

L
N

6

Ballast

Blue

Bla

Blk/W

Wh

Neutral
Line S1
S2

Bla

Blk/W

Wh

Neutral

815

DIAGRAM
14
Red

L
N

Red
Yel
Yel

15

Red
BlueRed
Red/Wht
BlueRed
Yel
Ballast
Ballast Yel

Red
Yel
Red/Wht
Blue
Blue Blue

Line

Black

Neutral

White

16
16
16

Red
L
DIAGRAM
15
Blue
N

Yel

Ballast

Blue
Red
Red/Wht
Yel
Red

7

Line

Bla

Neutral

Wh

Line

Bla

Wh
Neutral
Violet (control

Ballast

Gray (contro

Violet (contro

Gray (contro

BallastYel/Blk
Blue
Yel
Blue/Wht

BallastRed/Wht
Blue

(+)
Gray
(control
Black
(hot)-)
Violet (control +) L (-)
White (neutral) (+)
Gray (control -) N
(-)

Yel
Blue

Yel/Blk
Red/Wht
Red
Blue/Wht
Yel/Blk
Red
Blue/Wht

Black

17
7
10
17

White (neu

Ballast

DA
DA

17
17
17

Yel

White
Neutral
Violet (control
+)
Gray (control -)

Violet (control -)
Gray (control -)
Violet (control +)

Gray (control -)
Black (hot)

Black
(hot)
White
(neutral)
White (neutral)

Violet (control +)
Violet
Gray(control
(control+)
-)
Gray (control -)

Blue
Blue

Yel
Yel

L
N

Black (hot)
Violet (control
L
Red+)
White (neutral)Violet (control) DA
Gray (control
N (control)
Red-)
Violet
DA
Yel
Ballast Yel
DA
DA

8

(-)

18

L
LN
N

Ballast
Ballast
(+)
(+)
(-)
(-)

9

Red
Red
Red
Red
Yel
Yel
Yel

Line

19
12
9

Red
Red

Red
Red

Red
Red

Yel
Ballast
Yel Blue
Blue
Blue
Blue

Yel
Yel
Blue
Blue

Neutral

L
N

W

Vio

Gr

Red

W

Vio

20
1410

Gr

Blue

Red
Red

Red
L1
Ballast
L2 Black (hot) L Red
White White (neutral)
DA
Violet (control)
N
N Yel
DA
Violet (control) Ballast
Yel

Blk/Wht

20

Violet
(control -)
Black
(hot)
L
Gray (control -)
White (neutral)
N

Blue
Blue
(+)

Yel
Yel
Blue
Blue

Ballast
Red
Red

(-)
DIAGRAM
20

Ballast
Violet (control)

DA

Violet (control)

DA

Red
Red
Yel
Yel
Blue
Blue

Yel
Yel
Blue
Blue

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Red

W

Red

Ballast

Black

B
Blk

Yel
Blue
Blue
Blue
Blue

N

(-)

S1

S2
Neutral

Yel
Yel
Red
Blue
Red
Red
Blue
Yel
Yel
Ballast
Ballast Yel Yel
Black (hot)
L
BlueRed
White (neutral)
Blue
N
BlueRed
Blue
Yel
Ballast Yel

Black (hot)

W

Yel
Blue
Blue
Blue
Blue

L
DIAGRAM
18Red

White (neutral)

20

L

Ballast

Violet (contr

Line Gray
S1 (contB
Blk

S2
Neutral

DIAGRAM
17
(-)
(+)

Black (hot)

Line S1
S2

PAGE 2-22
Black (hot)

Blue
Blue
Red
Yel
Blue
Blue
Red
Red
Blue
Red
Yel
Ballast Yel
Yel

(+)
DIAGRAM
19Blue

Blue
Blue

Yel

Black

White (neu

Ballast

(+)

Gray (control -)

Ballast

(+)
(-)

Red
Red

Red
Red
Red
Yel
Red/Wht
Yel
Ballast
Ballast Yel
Blue

Violet (control +)

13
6 9

Gray (cont

10
18

Ballast

White (neutral)

Blue Blue
Blue Blue

Violet (contr

Red/Wht

Black
Line S1
Black
Line S1
Violet
(control +)L
Blk/Wht
(+)
S2
S2
Blk/Wht
Gray (control -)N
Neutral
White
(-)
White
Neutral

Red Red
Red Red
Yel

L
N
LL
NN
L
(+)
N
(-)

Violet
Violet(control
(control
+) (+)
Black -)(hot)
(+)
L
Violet
(control
Gray
(control
-) +)
Gray
(control
-) (+)
White
(neutral)
Black
(hot) (-)(-)
N
Gray (control -) L
White (neutral) (-)
N

Yel
Yel

Violet (controlBlue
+)
(+)
Blue
Gray (control
-)
(-)

6

Violet (control)

Yel

Red
Red

Ballast
Ballast
Yel

Yel

Black
Line S1
S2
Blk/Wht
Black (hot)
White
NeutralBlack (hot)White
L (neutral)
White (neutral)
N

Violet (control)

Red
Red

Black
(hot)
Black
(hot)
Black
LineWhite
White(neutral)
(neutral)

18 11
Blue
Blue

White

Neutral

Red

Ballast

(+)
Blue
DIAGRAM
16
(-)
Blue
Red

Violet (control +)
-)
Black
Line Gray (control

Red 10
DIAGRAM

Ballast

Blue
Blue

Ballast
Violet (control)

(+)
(-)

Black (hot)
Red
Black (hot)
Black
Line LS1
L
White (neutral)Violet (control) DA
NS2(control)
Red
Blk/Wht
White
(neutral)
Violet
N
DA
White
Neutral
Yel

Ballast

Black (hot)
L
White (neutral)Violet (control)
N (control)
Violet

Yel

9

Ballast

Blue
Blue

Yel

Ballast
Black (hot)
Violet (control)
WhiteDA
(neutral)
Violet (control)
DA

8

Ballast

Violet (control +)

DIAGRAM 11

5

DA
DA

White

Black
Line
L
White
Neutral
N
Black
LineViolet (control
+) L
(+)
White
Neutral
Gray (control
-) N
(-)

Red

Red/Wht
Yel
Red
Red
RedRed/Wht
BlueBallast
Blue
Blue
Yel
Yel

Red
Red

Violet (control -)

Violet (control)

L
DIAGRAM
3
N

Black (hot)

L
N

Yel

Blue

White (neutral)

Blk/Wht

Line S1
S2

Yel
Red
Yel
Red
Red
Blue
Yel
Red
Blue
Yel
Yel
Blue
Yel
Blue
Blue
Blue

Yel

4

Violet (control)

4

DA

Ballast

L1
L2
L1
N
L2
N

Black
Line S1
S2
Blk/Wht
Violet
(control +) White
Neutral
(+)
Gray (control -)
(-)

Yel
Yel
Black (hot)
L
Red
Violet (control
+)(hot)
White (neutral)Violet (control)
BlueRed
DABlack
N (control)
Red-) (+) L Blue
Gray
(control
Violet
Black
Line
White
(-) N Blue
BlueRedRed
DA (neutral)
Neutral Yel White
L
Red/Wht
Ballast Yel
Yel
N Ballast
Black
Line
Violet (control)
BallastYel Red
DA
Blue
Neutral
Violet
(control +)White L
Violet (control)
Red/Wht
(+)
Blue
DA
Blue Black
Yel
Line
Red
Violet
(control
Gray
(control
-) +) (+)
(-) N
Blue
White
Neutral
Gray (control
-) L
Red/Wht
(-)
Ballast
Blue
N
Black (hot)
RedYel
Violet (control +)L
(+) Ballast
White(hot)
(neutral)
Black
L -)N
Red Red
Gray (control
Yel
(-)
WhiteViolet
(neutral)
Blue
(control
N +) (+)
Red
Gray (control -)
(-) Ballast
Yel Blue
Ballast
Black +)
(hot)
Yel
Violet (control
Red
(+)L
Blue
White
Violet Gray
(control
-)(neutral)
(control
-)
Red
(+) (-) N
Blue Blue
Gray (control -)
(-)
Blue
Yel
Ballast Yel

Ballast
Violet (control)

Black
Blk/Wht
Black
White

Black (hot)

Yel

7
10
10

9

Red

Black (hot) Red
L
Yel
N

3

L2
N

White

S1
Black
Line
Violet
(control
Black+)(hot)(+)
L
S2 -) Blk/Wht
GrayWhite
(control
(neutral)(-)
N
White
Neutral

DIAGRAM 9

9

White (neutral)

Ballast

B

Neutral

Blue
Red
Blue
Red

L1

Blk/Wht

White (neutral)

Yel

Blue

Ballast

Blue

DA

Black

Ballast

Red/Wht

(-)

14
14
14

DIAGRAM 12
Blue

White

Neutral

29

Ballast
Red
Red

Black

Line S1
S2
S1
Line
Neutral
S2

DIAGRAM 8

1

Black (hot)

Yel
Red
RedYel
Red
RedRed
Blue
Yel
Red
BallastYelBlue
Ballast Yel Yel
Yel
Ballast RedBlue
Yel
Blue
Red
Blue
Blue
Blue
Ballast
Blue
Red
Red
Blue

Blk/Wht

Neutral

15
DIAGRAM 78 15
15
Blue

Line S1
S2

Ballast

Ballast

Red

(+)

B

Neutral

Blue
Red
Red

Black
Blk/Wht
White

Line S1
S2

Blue

Ballast

Blue
Yel
Yel

Line S1
S2

Ballast

Ballast case must be grounded. A star washer
or other paint penetrating device is required

White (neutral)

12
6
12
12
13
13

White

Neutral

Ballast
Ballast
Yel

Blue
Blue

Blk/Wht

Line S1
S2

Blue
Blue

Red
Red

Yel
Yel
Red
Red
Blue

Ballast

White
Neutral
Black
Line S1
Violet (control)
S2
Blk/Wht DA
White DA
Neutral Violet (control)

8

(+)
(-)

White
Neutral
White (neutral)
Black
Line S1
S2
Blk/Wht
S1 (hot) Ballast
Black
Black
Line
White
Neutral
L
White
(neutral)Blk/Wht
Violet (control
+)S2
N
(+)
White
Neutral
Gray (control
-)
(-)

Black

Ballast

Black
L
N

Line S1
S2

Black
Line S1
Black (hot)
L
S2
Blk/Wht
White
S1 (neutral)
Black
Line
N
White
Neutral
S2
Blk/Wht

Blue
Blue

BlueRed
BlueRed

Blk/Wht

White

Neutral

Ballast
Gray (control -)

Blk/Wht

Blue

Violet (control
Black+)(hot)(+)
L
GrayWhite
(control
-)
(neutral)
(-) N

Violet (control +)

11

Blue

Red
Red

Ballast

-D, DP1

Blue

Red
Red

Neutral

Line S1
S2

13
13
13

7

L
N

DA

Ballast

Yel
White
Neutral
Ballast Yel
Black
Line S1
Ballast Red
Violet (control)
S2
Blk/Wht
DA
Blue
Red
S1
Black
Line
Violet
(control)
White
Neutral
Red
DA
Blue
Blue
S2
Blk/Wht
Red
Ballast Blue
White
Neutral
Black (hot)
White (neutral)

Blue

Black

Neutral

Blue

DIAGRAM 5

Note: Nominal dimensions provided above
Contact Universal for drawings
and/or tolerances
Ballast
Violet (control)

DA

Violet (control)

Mounting Dimensions
H	
M	
X

W	

Yel
Yel

Ballast

Ballast
Violet (control)

Violet (control)

DA

4
DIMENSIONS
AND WIRING DIAGRAMS
11

3
Black (hot)

Yel
Yel

Ballast

Ballast
Violet (control)

VariPRO
VariPRO DIMMING BALLASTS

0-10V
DIMMING
T8

PARALLEL LAMP

1

Line	
Current	
(Amps)	

Input	
Power	
(Watts)	

Power			
Factor	 Ballast	
THD	
(PF)	
Factor (BF)	
%	

Min. F/C	
Start	 Wiring	
Temp1	Diag.	 Dim.

0.15	17	
		
	
		
0.07	17	0.90	0.87	
< 19	
32/0	
18	
-A
0.06	 17	
		
		
0.27	32	 	
		
	
		
0.11	31	0.96	0.87	
< 12	
32/0	
8	
-A
0.09	
31
0.15	24	
		
	
		
0.09	23	0.94	0.87	
< 15	
32/0	
18	
-A
0.07	 23	
		
		
0.36	45	 	
		
	
		
0.15	44	0.98	0.87	
< 10	
32/0	
8	
-A
0.12	
44
0.26	31	
		
	
		
0.11	30	0.96	0.88	
< 12	
32/0	
18	
-A
		
0.09	 30	
		
0.48	57	 	
		
	
		
0.21	57	0.98	0.87	
< 10	
32/0	
8	
-A
0.16	
57
0.31	38	
		
	
		
0.13	37	0.97	0.87	
< 10	
32/0	
18	
-A
0.11	 37	
		
	
		
0.59	71	
		
	
		
0.25	70	0.99	0.87	
< 10	
32/0	
8	
-A
0.20	
70
0.25	30	
		
	
		
0.11	29	0.95	0.87	
< 12	
60/15	
18	
-A
0.09	 29	
		
	
		
0.46	55	
		
	
		
0.19	54	0.98	0.87	
< 10	
60/15	
8	
-A
0.16	
54
0.22	26	
		
	
		
0.09	26	0.94	0.87	
< 14	
60/15	
18	
-A
0.09	 26	
		
	
		
0.40	49	
		
	
		
0.17	48	0.98	0.87	
< 10	
60/15	
8	
-A
0.14	
48
0.20	24	
		
	
		
0.09	23	0.94	0.87	
< 15	
60/15	
18	
-A
		
0.07	 23	
	
		
0.37	45	
		
	
		
0.16	44	0.98	0.87	
< 10	
60/15	
8	
-A
0.13	
44

A short stabilization period may be needed for temperatures below 10C

See page 2-22­­­­ for Dimensions
and Wiring Diagrams

PAGE 2-23

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent Dimming

	 Lamp	
		
		Starting	 Line	
Catalog	
	Qty.	 Method	
Volts	
Number	
F17T8
	
	120	
B232PUSV3PLA	
	 1		 PRS	277	
B232PUSV3PLA	
	
	347	
B232P3SV3PLA	
	 	
	120	
B232PUSV3PLA	
	
	 2	 PRS	277	
B232PUSV3PLA	
			
347	
B232P3SV3PLA	
F25T8
	
	120	
B232PUSV3PLA	
B232PUSV3PLA	
	 1		 PRS	277	
	
	347	
B232P3SV3PLA	
	 	
	120	
B232PUSV3PLA	
	
	 2	 PRS	277	
B232PUSV3PLA	
			
347	
B232P3SV3PLA	
F32T8
	
	120	
B232PUSV3PLA	
	 1		 PRS	277	
B232PUSV3PLA	
	
	347	
B232P3SV3PLA	
	 	
	120	
B232PUSV3PLA	
	
	 2	 PRS	277	
B232PUSV3PLA	
			
347	
B232P3SV3PLA	
F40T8
	
	120	
B232PUSV3PLA	
B232PUSV3PLA	
	 1		 PRS	277	
	
	347	
B232P3SV3PLA	
B232PUSV3PLA	
	 	
	120	
	
	 2	 PRS	277	
B232PUSV3PLA	
			
347	
B232P3SV3PLA	
F32T8 (30W)
	
	120	
B232PUSV3PLA	
B232PUSV3PLA	
	 1		 PRS	277	
	
	347	
B232P3SV3PLA	
	 	
	120	
B232PUSV3PLA	
	
	 2	 PRS	277	
B232PUSV3PLA	
			
347	
B232P3SV3PLA	
F28T8
	
	120	
B232PUSV3PLA	
	 1		 PRS	277	
B232PUSV3PLA	
	
	347	
B232P3SV3PLA	
	 	
	120	
B232PUSV3PLA	
	
	 2	 PRS	277	
B232PUSV3PLA	
			
347	
B232P3SV3PLA	
F30T8 (25W)
	
	120	
B232PUSV3PLA	
	 1		 PRS	277	
B232PUSV3PLA	
	
	347	
B232P3SV3PLA	
	 	
	120	
B232PUSV3PLA	
	
	 2	 PRS	277	
B232PUSV3PLA	
			
347	
B232P3SV3PLA	

VariPRO

VariPRO DIMMING BALLASTS

Fluorescent Dimming

0-10V
DIMMING
T5

	 Lamp	
		
		Starting	 Line	
Catalog	
	Qty.	 Method	
Volts	
Number	
F14T5
	
	120	
B228PUSV3PLA	
	 1		 PRS	277	
B228PUSV3PLA	
	
	347	
B228P3SV3PLA	
	 	
	120	
B228PUSV3PLA	
	
	 2	 PRS	277	
B228PUSV3PLA	
			
347	
B228P3SV3PLA	
F21T5
	
	120	
B228PUSV3PLA	
B228PUSV3PLA	
	 1		 PRS	277	
	
	347	
B228P3SV3PLA	
	 	
	120	
B228PUSV3PLA	
	
	 2	 PRS	277	
B228PUSV3PLA	
			
347	
B228P3SV3PLA	
F28T5
	
	120	
B228PUSV3PLA	
	 1		 PRS	277	
B228PUSV3PLA	
	
	347	
B228P3SV3PLA	
	 	
	120	
B228PUSV3PLA	
	
	 2	 PRS	277	
B228PUSV3PLA	
			
347	
B228P3SV3PLA	
F28T5ES (25W)
	
	120	
B228PUSV3PLA	
B228PUSV3PLA	
	 1		 PRS	277	
	
	347	
B228P3SV3PLA	
B228PUSV3PLA	
	 	
	120	
	
	 2	 PRS	277	
B228PUSV3PLA	
			
347	
B228P3SV3PLA	
1

PARALLEL LAMP

Line	
Current	
(Amps)	

Input	
Power	
(Watts)	

Power			
Factor	 Ballast	
THD	
(PF)	
Factor (BF)	
%	

Min. F/C
Start	 Wiring
Temp1	Diag.	 Dim.

0.17	19	
		
	
		
0.07	18	0.93	1.00	
< 17	
50/10	
18	
-A
0.06	 19	
		
		
0.30	34	 	
		
	
		
0.13	33	0.97	1.00	
< 10	
50/10	
8	
-A
0.11	
34
0.23	26	
		
	
		
0.10	25	0.95	1.00	
< 13	
50/10	
18	
-A
0.09	 26	
		
		
0.42	48	 	
		
	
		
0.18	47	0.98	1.00	
< 10	
50/10	
8	
-A
0.15	
47
0.29	33	
		
	
		
0.13	33	0.97	1.00	
< 10	
50/10	
18	
-A
		
0.11	 34	
		
0.56	64	 	
		
	
		
0.24	63	0.99	1.00	
< 10	
50/10	
8	
-A
0.19	
63
0.27	31	
		
	
		
0.12	31	0.96	1.00	
< 12	
60/15	
18	
-A
0.09	 30	
		
	
		
0.51	59	
		
	
		
0.22	57	0.99	1.00	
< 10	
60/15	
8	
-A
0.17	
58

A short stabilization period may be needed for temperatures below 10C

See page 2-22 for Dimensions
and Wiring Diagrams

PAGE 2-24

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

VariPRO

VariPRO DIMMING BALLASTS

0-10V
DIMMING
T5HO

PARALLEL LAMP

1

Line	
Current	
(Amps)	

Input	
Power	
(Watts)	

Power			
Factor	 Ballast	
THD	
(PF)	
Factor (BF)	
%	

Min. F/C	
Start	 Wiring	
Temp1	Diag.	 Dim.

0.46	54	
		
	
		
0.21	56	0.97	1.00	
< 10	
32/0	
18	
-D
0.18	 58	
		
		
0.98	116	 	
		
	
		
0.42	112	0.99	1.00	
< 10	
32/0	
8	
-D
0.33	
109
0.44	52	
		
	
		
0.20	53	0.96	1.00	
< 10	
60/15	
18	
-D
0.16	 54	
		
		
0.86	102	 	
		
	
		
0.38	101	0.99	1.00	
< 10	
60/15	
8	
-D
0.30	
101
0.47	58	
		
	
		
0.21	58	0.97	0.90	
< 10	
60/15	
18	
-D
		
0.17	 57	
		
0.89	109	 	
		
	
		
0.38	105	0.99	0.90	
< 10	
60/15	
8	
-D
0.31	
108
0.45	54	
		
	
		
0.19	53	0.96	0.90	
< 10	
60/15	
18	
-D
0.16	 56	
		
	
		
0.86	105	
		
	
	
0.37	103	0.98	0.90	
< 10	
60/15	
8	
-D
0.30	
105

A short stabilization period may be needed for temperatures below 10C

See page 2-22­­­­ for Dimensions
and Wiring Diagrams

PAGE 2-25

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent Dimming

	 Lamp	
		
		Starting	 Line	
Catalog	
	Qty.	 Method	
Volts	
Number	
F54T5HO
	
	120	
B254PUSV3PLD	
	 1		 PRS	277	
B254PUSV3PLD	
	
	347	
B254P3SV3PLD	
	 	
	120	
B254PUSV3PLD	
	
	 2	 PRS	277	
B254PUSV3PLD	
			
347	
B254P3SV3PLD	
F54T5HOES (49W)
	
	120	
B254PUSV3PLD	
B254PUSV3PLD	
	 1		 PRS	277	
	
	347	
B254P3SV3PLD	
	 	
	120	
B254PUSV3PLD	
	
	 2	 PRS	277	
B254PUSV3PLD	
			
347	
B254P3SV3PLD	
FT55W/2G11
	
	120	
B254PUSV3PLD	
	 1		 PRS	277	
B254PUSV3PLD	
	
	347	
B254P3SV3PLD	
	 	
	120	
B254PUSV3PLD	
	
	 2	 PRS	277	
B254PUSV3PLD	
			
347	
B254P3SV3PLD	
FC55T5HO
	
	120	
B254PUSV3PLD	
B254PUSV3PLD	
	 1		 PRS	277	
	
	347	
B254P3SV3PLD	
B254PUSV3PLD	
	 	
	120	
	
	 2	 PRS	277	
B254PUSV3PLD	
			
347	
B254P3SV3PLD	

LevelPRO

LevelPRO DIMMING BALLASTS

Fluorescent Dimming

STEP-DIMMING
HIGH BALLAST
FACTOR

	 Lamp	
		
		Starting	 Line	
Catalog	
	Qty.	 Method	
Volts	
Number	
F17T8
	
	120	
B232PUS50PLHA	
	 1		 PRS	277	
B232PUS50PLHA	
	
	347	
B232P3S50PLHA	
	 	
	120	
B232PUS50PLHA	
	
	 2	 PRS	277	
B232PUS50PLHA	
			
347	
B232P3S50PLHA	
F25T8
	
	120	
B232PUS50PLHA	
B232PUS50PLHA	
	 1		 PRS	277	
	
	347	
B232P3S50PLHA	
	 	
	120	
B232PUS50PLHA	
	
	 2	 PRS	277	
B232PUS50PLHA	
			
347	
B232P3S50PLHA	
F32T8
	
	120	
B232PUS50PLHA	
	 1		 PRS	277	
B232PUS50PLHA	
	
	347	
B232P3S50PLHA	
	 	
	120	
B232PUS50PLHA	
	
	 2	 PRS	277	
B232PUS50PLHA	
			
347	
B232P3S50PLHA	
F32T8 (30W)
	
	120	
B232PUS50PLHA	
B232PUS50PLHA	
	 1		 PRS	277	
	
	347	
B232P3S50PLHA	
B232PUS50PLHA	
	 	
	120	
	
	 2	 PRS	277	
B232PUS50PLHA	
			
347	
B232P3S50PLHA	
F28T8
	
	120	
B232PUS50PLHA	
B232PUS50PLHA	
	 1		 PRS	277	
	
	347	
B232P3S50PLHA	
	 	
	120	
B232PUS50PLHA	
	
	 2	 PRS	277	
B232PUS50PLHA	
			
347	
B232P3S50PLHA	
F30T8 (25W)
	
	120	
B232PUS50PLHA	
	 1		 PRS	277	
B232PUS50PLHA	
	
	347	
B232P3S50PLHA	
	 	
	120	
B232PUS50PLHA	
	
	 2	 PRS	277	
B232PUS50PLHA	
			
347	
B232P3S50PLHA	
1

PARALLEL LAMP

Line	
Current	
(Amps)	

Input	
Power	
(Watts)	

Power			
Factor	 Ballast	
THD	
(PF)	
Factor (BF)	
%	

Min. F/C	
Start	 Wiring	
Temp1	Diag.	 Dim.

0.19	23	
		
	
		
0.08	23	0.96	1.15	
< 15	
32/0	
19	
-A
0.07	 22	
		
		
0.35	42	 	
		
	
		
0.15	41	0.98	1.15	
< 10	
32/0	
12	
-A
0.12	
41
0.27	32	
		
	
		
0.12	32	0.97	1.15	
< 10	
32/0	
19	
-A
0.09	 31	
		
		
0.50	60	 	
		
	
		
0.21	59	0.99	1.15	
< 10	
32/0	
12	
-A
0.17	
59
0.34	40	
		
	
		
0.15	40	0.98	1.15	
< 10	
32/0	
19	
-A
		
0.12	 39	
		
0.64	77	 	
		
	
		
0.27	75	0.99	1.15	
< 10	
32/0	
12	
-A
0.22	
75
0.32	38
		
	
			
0.14	38	
0.98	1.15	 < 10	
60/15	
19	
-A
0.11	 38	
		
	
		
0.60	72	
		
	
		
0.25	70	0.99	1.15	
< 10	
60/15	
12	
-A
0.20	
69
0.28	34	
		
	
		
0.12	33	0.98	1.15	
< 10	
60/15	
19	
-A
0.10	 33	
		
	
		
0.54	65	
		
	
		
0.23	63	0.99	1.15	
< 10	
60/15	
12	
-A
0.18	
63
0.27	32	
		
	
		
0.12	32	0.97	1.15	
< 10	
60/15	
19	
-A
0.09	 31	
		
	
		
0.50	60	
		
	
		
0.21	59	0.99	1.15	
< 10	
60/15	
12	
-A
0.17	
59

A short stabilization period may be needed for temperatures below 10C

See page 2-22­­­­ for Dimensions
and Wiring Diagrams

PAGE 2-­26

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

LevelPRO

LevelPRO DIMMING BALLASTS

STEP-DIMMING
NORMAL BALLAST
FACTOR

LIGHT-LEVEL SWITCHING
PARALLEL LAMP

1

Line	
Current	
(Amps)	

Input	
Power	
(Watts)	

Power			
Factor	 Ballast	
THD	
(PF)	
Factor (BF)	
%	

Min. F/C	
Start	 Wiring	
Temp1	Diag.	 Dim.

0.15	17	
		
	
		
0.06	17	0.94	0.87	
< 19	
32/0	
19	
-A
0.05	 17	
		
		
0.26	31	 	
		
	
		
0.11	31	0.97	0.87	
< 10	
32/0	
12	
-A
0.09	
31
0.21	25	
		
	
		
0.09	25	0.96	0.87	
< 14	
32/0	
19	
-A
0.07	 25	
		
		
0.38	46	 	
		
	
		
0.16	44	0.98	0.87	
< 10	
32/0	
12	
-A
0.13	
44
0.26	31	
		
	
		
0.11	31	0.97	0.88	
< 11	
32/0	
19	
-A
		
0.09	 31	
		
0.48	59	 	
		
	
		
0.21	58	0.99	0.87	
< 10	
32/0	
12	
-A
0.17	
58
0.32	39	
		
	
		
0.14	38	0.98	0.87	
< 10	
32/0	
19	
-A
0.11	 38	
		
	
		
0.61	74	
		
	
		
0.26	72	0.99	0.87	
< 10	
32/0	
12	
-A
0.21	
72
0.24	29	
		
	
		
0.10	29	0.97	0.87	
< 12	
60/15	
19	
-A
0.08	 29	
		
	
		
0.46	56	
		
	
		
0.19	54	0.99	0.87	
< 10	
60/15	
12	
-A
0.16	
54
0.22	26	
		
	
		
0.09	26	0.96	0.87	
< 14	
60/15	
19	
-A
0.08	 25	
		
	
		
0.41	49	
		
	
		
0.17	48	0.99	0.87	
< 10	
60/15	
12	
-A
0.14	
48

A short stabilization period may be needed for temperatures below 10C

See page 2-22­­­­ for Dimensions
and Wiring Diagrams

See page 2-20­­­­ for Dimensions
and Wiring Diagrams
PAGE 2-­27

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Fluorescent Dimming

	 Lamp	
		
		Starting	 Line	
Catalog	
	Qty.	 Method	
Volts	
Number	
F17T8
	
	120	
B232PUS50PLA	
	 1		 PRS	277	
B232PUS50PLA	
	
	347	
B232P3S50PLA	
	 	
	120	
B232PUS50PLA	
	
	 2	 PRS	277	
B232PUS50PLA	
			
347	
B232P3S50PLA	
F25T8
	
	120	
B232PUS50PLA	
B232PUS50PLA	
	 1		 PRS	277	
	
	347	
B232P3S50PLA	
	 	
	120	
B232PUS50PLA	
	
	 2	 PRS	277	
B232PUS50PLA	
			
347	
B232P3S50PLA	
F32T8
	
	120	
B232PUS50PLA	
	 1		 PRS	277	
B232PUS50PLA	
	
	347	
B232P3S50PLA	
	 	
	120	
B232PUS50PLA	
	
	 2	 PRS	277	
B232PUS50PLA	
			
347	
B232P3S50PLA	
F40T8
	
	120	
B232PUS50PLA	
B232PUS50PLA	
	 1		 PRS	277	
	
	347	
B232P3S50PLA	
B232PUS50PLA	
	 	
	120	
	
	 2	 PRS	277	
B232PUS50PLA	
			
347	
B232P3S50PLA	
F32T8 (30W)
	
	120	
B232PUS50PLA	
B232PUS50PLA	
	 1		 PRS	277	
	
	347	
B232P3S50PLA	
	 	
	120	
B232PUS50PLA	
	
	 2	 PRS	277	
B232PUS50PLA	
			
347	
B232P3S50PLA	
F28T8
	
	120	
B232PUS50PLA	
	 1		 PRS	277	
B232PUS50PLA	
	
	347	
B232P3S50PLA	
	 	
	120	
B232PUS50PLA	
	
	 2	 PRS	277	
B232PUS50PLA	
			
347	
B232P3S50PLA	

LevelPRO

LevelPRO DIMMING BALLASTS

Fluorescent Dimming

STEP-DIMMING
NORMAL BALLAST
FACTOR

	 Lamp	
		
		Starting	 Line	
Catalog	
	Qty.	 Method	
Volts	
Number	
F30T8 (25W)
	
	120	
B232PUS50PLA	
	 1		 PRS	277	
B232PUS50PLA	
	
	347	
B232P3S50PLA	
	 	
	120	
B232PUS50PLA	
	
	 2	 PRS	277	
B232PUS50PLA	
			
347	
B232P3S50PLA	
F14T5
	
	120	
B232PUS50PLA	
B232PUS50PLA	
	 1		 PRS	277	
	
	347	
B232P3S50PLA	
	 	
	120	
B232PUS50PLA	
	
	 2	 PRS	277	
B232PUS50PLA	
			
347	
B232P3S50PLA	
F21T5
	
	120	
B232PUS50PLA	
	 1		 PRS	277	
B232PUS50PLA	
	
	347	
B232P3S50PLA	
	 	
	120	
B232PUS50PLA	
	
	 2	 PRS	277	
B232PUS50PLA	
			
347	
B232P3S50PLA	
F28T5
	
	120	
B232PUS50PLA	
B232PUS50PLA	
	 1		 PRS	277	
	
	347	
B232P3S50PLA	
B232PUS50PLA	
	 	
	120	
	
	 2	 PRS	277	
B232PUS50PLA	
			
347	
B232P3S50PLA	
F28T5ES (25W)
	
	120	
B232PUS50PLA	
B232PUS50PLA	
	 1		 PRS	277	
	
	347	
B232P3S50PLA	
	 	
	120	
B232PUS50PLA	
	
	 2	 PRS	277	
B232PUS50PLA	
			
347	
B232P3S50PLA	
1

LIGHT-LEVEL SWITCHING
PARALLEL LAMP
Line	
Current	
(Amps)	

Input	
Power	
(Watts)	

Power			
Factor	 Ballast	
THD	
(PF)	
Factor (BF)	
%	

Min. F/C	
Start	 Wiring	
Temp1	Diag.	 Dim.

0.21	25	
		
	
		
0.09	25	0.96	0.87	
< 14	
60/15	
19	
-A
0.07	 25	
		
		
0.38	46	 	
		
	
		
0.16	44	0.98	0.87	
< 10	
60/15	
12	
-A
0.13	
44
0.16	19	
		
	
		
0.07	19	0.94	1.00	
< 17	
50/10	
19	
-A
0.06	 19	
		
		
0.30	34	 	
		
	
		
0.13	34	0.98	1.00	
< 10	
50/10	
12	
-A
0.10	
34
0.23	26	
		
	
		
0.10	26	0.96	1.00	
< 12	
50/10	
19	
-A
		
0.08	 26	
		
0.42	49	 	
		
	
		
0.18	48	0.99	1.00	
< 10	
50/10	
12	
-A
0.14	
48
0.29	34	
		
	
		
0.12	33	0.97	1.00	
< 10	
50/10	
19	
-A
0.10	 33	
		
	
		
0.56	65	
		
	
		
0.24	63	0.99	1.00	
< 10	
50/10	
12	
-A
0.19	
63
0.26	30	
		
	
		
0.11	30	0.97	1.00	
< 12	
60/15	
19	
-A
0.09	 29	
		
	
		
0.51	59	
		
	
		
0.25	58	0.97	1.00	
< 10	
60/15	
12	
-A
0.17	
58

A short stabilization period may be neede

See page 2-22­­­­ for Dimensions
and Wiring Diagrams

PAGE 2-­28

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Notes

Fluorescent Dimming

PAGE 2-­29

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Compact Fluorescent
Ballasts
The Courage To Dream Small
Universal Lighting Technologies (“Universal”) offers a full
range of electronic programmed start compact fluorescent
ballasts to address most commercial applications.
Our electronic models offer high efficiency for maximum
energy savings and installer-friendly universal input
voltage, which reduces your inventory and ensures that
you have the right voltage ballast every time. A complete
range of 347 volt models are also available that offer
outstanding reliability and lamp performance. These models
feature a low profile case that fits in any fixture. And their
metal housing construction meets all plenum codes and
delivers maximum heat transfer to extend ballast life.

Compact Fluorescent

Our compact fluorescent models offer installer-friendly universal input voltage.

Universal Lighting Technologies is a member of the Panasonic Group

Product Overview
Triad® Electronic CFL Ballasts:
• High efficiency for maximum energy savings.
• Universal input voltage of 120-277V. Installer friendly universal input voltage, which reduces inventory and ensures that
you have the right voltage ballast every time.
• Complete range of 347 volt CFL models that offer outstanding reliability and lamp performance.
• Programmed Rapid Startiting (PRS) incorporated. PRS is recommended by all lamp manufacturers. Increases lamp life for
those frequently switched applications where occupancy sensors are used. Meets all requirements of rapid start specs
and more.
• Metal can construction. Metal housing construction meets all plenum codes and construction code requirements.
	 It also delivers maximum heat transfer to extend ballast life. Designed and manufactured for long life.
• Meets all applicable regulatory and safety standards. ANSI C82.11 Ballast Specification, UL 935, FCC Part 18 (Class A),
and UL2043 suitable for Air Handling spaces.
• 1- or 2- lamp operation of multiple lamp applications. Multiple lamp options on each ballast for added versatility in
	applications.
• THD<10%
• Type CC and Type HL (hazardous locations) rated. Type CC is an anti-arcing feature that is used to reduce arcing caused
by loose connections or improper lamp-pin to lampholder contact. The Type CC feature senses this arcing and shuts
down the ballastt to prevent damage.
• Dual entry color coded wire trap terminals. For wiring accuracy and ease of installation.
• Low profile form case fits in any fixture. Use for surface or junction box mounting. Small size means less wasted space
than full alternative.
• End of lamp life shutdown circuit. Meets ANSI/NEMA requirements. Allows you to replace failed lamps without turning off
power.
• 75° C Temperature Test point. Maximum Case Temperature of 75° C allows for easy ballast/fixture testing, assuring
proper temperature application.
• Lamp proximity. Lamps can be mounted in close proximity to these ballasts due to no temperature critical components
near the can sides. And, their circuit board potting enhances reliability by lowering case temperatures.
• Warranty. Backed by Triad® five year warranty.

Compact Fluorescent

CFL Replacement Kits
The multi-exit ballast lead wire connectors accommodate side and bottom lead exit requirements. The snap mount adapter
plate adds bottom-exit studs and additional flexibility for replacement of older magnetic ballasts. They also fit virtually every
j-box cover and fixture application. This product is for distribution sale only.
Mult-E Kit products:
C213UNVME000K	
C218UNVME000K	
C2642UNVME000K	

C213/347ME001K
C218/347ME001K
C2642/347ME001K

Mult-E Kit contains:
• Multi-exit ballast for use in both side-exit and bottom-exit replacement applications.
• Snap-mount adapter plate speeds up installation time. No hardware required for attaching snap-mount adapter plate.
• Lead wire set
• Wire extraction tool
• Instructions
FOR MORE INFORMATION CALL

PAGE 3-2

1-800-BALLAST
(225-5278)

Understanding Compact Fluorescent Technology
Compact fluorescent (CFL) lamps are single-ended and
plug into sockets. They’re sometimes referred to as
“single-based” or “single-ended” fluorescent lamps.
Lamp Shapes
Today’s CFL lamps come in these basic shapes: twin tube,
quad, triple, multi, square and circular. Each of these
shapes has its own subset of sizes. For example, the twin
tube may range from 4˝ long (5 watt) to 22˝ long (40 watt).

OR

OR

Long Twin T5, 4-Pin
5w – 80w

Twin, 2-Pin
5w – 13w

OR

2-Pin
4-Pin
Quad 9w – 27w

Square (2D)
10w – 55w

Lamp Bases
There are a variety of lamp bases used with today’s CFL
lamps. This provides a safeguard to make sure that the
proper lamp/ballast combination is installed. The lamp
base style is part of the ANSI/NEMA
designation.
In this catalog, Universal CFL ballasts are classified
according to lamp type. Icons representing each lamp
type provide a quick visual reference. Within each
classification, the lamps and their appropriate ballasts
can be found by referring to the generic NEMA lamp
descriptions.
Lamp Designation
There are two different industry-recognized
nomenclatures for identifying CFL lamps: ANSI
Lamp Designations and NEMA Lamp Designations.
Here are examples of each:
ANSI Designation

13W / 7T4 / T / GX23 / PH
Lamp
Wattage

Multiple, 4-Pin
(GE & OSI)
18w – 70w

Multiple, 4-Pin
(Philips)
18w – 42w

T5 Circular
22w - 55w

Lamp
Diameter
1/8˝

Base
Starting:
PH – Preheat
RS – Rapid Start

CFT 13W / GX23

Twin (T)
Quad (Q)
Multi (M)
2D (S)

Lamp
Wattage

Base

Both lamp designations refer to lamp wattage, shape,
and base type. Since the NEMA designation is shorter, it
will probably be the nomenclature of choice in the future.
All of the major lamp companies have trade names for
various CFL lamp types, such as GE’s “Biax” and “2D”
lamps, OSI’s “Dulux,” and Philips’ “PL”. These names
have become more widely used than either of the industry designations.
GE	
OSI	Philips
Low Watt Biax	
Dulux S, S/E	
PL-S
Double Biax	
Dulux D, D/E 	PL-C
Biax T/E	
Dulux T, T/E, T/E/IN	PL-T
Biax Q/E	
Dulux T/E/IN	
PL-T
High Lumen Biax	
Dulux L, F	
PL-L
2D	
––	
––
—	
Pentron	
Silhouette

FOR MORE INFORMATION CALL

PAGE 3-3

1-800-BALLAST
(225-5278)

Compact Fluorescent

Industry	
Watts	
Single or Twin	
5, 7, 9, 13	
Double or Quad	
9, 13, 18, 20, 26, 27	
Multiple	
13, 18, 26, 32, 42	
Multiple	
42, 57, 70	
Long Twin T5	
18, 24/27, 36/39, 40, 50, 80	
Square	
10, 16, 21, 28, 38, 55	
Circline	
22, 40, 55	

Twin (T)
Quad (Q)
Multi (M)
2D (S)

NEMA Designation

Pins and Starters
CFL lamps feature either two pins or four pins.
Four-pin lamps are traditionally powered by electronic
ballasts. These lamps do not have an internal starter, so
the other filament terminals (pins) are made
accessible for external connection to the ballasts.

Lamp
Length

Configurations
Electronic Bottom Exit (BE)

Electronic Multi-Exit with Studs (MES)

Compact Fluorescent

Electronic Multi-Exit (ME)

FOR MORE INFORMATION CALL

PAGE 3-4

1-800-BALLAST
(225-5278)

Lamp Matrix
	
	

ANSI Lamp	
Designation	

NEMA Lamp	
Built-In	
LAMP MANUFACTURER
Designation	Starter	GE	
OSI	

Philips

	5W/4T4/T/G23/PH	
CFT5W/G23	
	7W/5T4/T/G23/PH	
CFT7W/G23	
	9W/6T4/T/G23/PH	
CFT9W/G23	
	 13W/7T4/T/GX23/PH	CFT13W/GX23	

YES	
YES	
YES	
YES	

F5 BX	
F7 BX	
F9 BX	
F13 BX	

CF 5DS	
CF 7DS	
CF 9DS	
CF 13DS	

PL-S 5W
PL-S 7W
PL-S 9W
PL-S 13W

	 9W/4T4/Q/G23-2/PH	
	 13W/5T4/Q/GX23-2/PH	

CFQ9W/G23	
CFQ13W/GX23	

YES	
YES	

F9 DBX23	
F13 DBX23	

CF 9DD	
CF 13DD	

—
PL-C 13W/USA

	 13W/6T4/Q/G24d-1/PH	
	 18W/7T4/Q/G24d-2/PH	
	 26W/8T4/Q/G24d-3/PH	

CFQ13W/G24d	
CFQ18W/G24d	
CFQ26W/G24d	

YES	
YES	
YES	

F13 DBX T4	
F18 DBX T4	
F26 DBX T4	

—	
CF 18DD	
CF 26DD	

PL-C 13W
PL-C 18W
PL-C 26W

	13W/6T4/Q/G24q-1	
	18W/7T4/Q/G24q-2	
	26W/8T4/Q/G24q-3	

CFQ13W/G24q	
CFQ18W/G24q	
CFQ26W/G24q	

NO	
NO	
NO	

F13 DBX/4P	
F18 DBX/4P	
F26 DBX/4P	

CF 13DD/E	
CF 18DD/E	
CF 26DD/E	

PL-C 13W/4P
PL-C 18W/4P
PL-C 26W/4P

	10W/3.5T4/S/GR10q-4	
	16W/5.5T4/S/GR10q-4	
	21W/5.5T4/S/GR10q-4	
	28W/8T6/S/GR8-2/PH	
	28W/8T6/S/GR10q-4	
	38W/8T6/S/GR10q-4	
	55W/8T6/S/GRY10q-3	

CFS10W/GR10q	
CFS16W/GR10q	
CFS21W/GR10q	
CFS28W/GR8	
CFS28W/GR10q	
CFS38W/GR10q	
CFS55W/GRY10q	

NO	
NO	
NO	
YES	
NO	
NO	
NO	

F10 2D/4P	
F16 2D/4P	
F21 2D/4P	
F28 2D	
F28 2D/4P	
F38 2D/4P	
F55 2D/4P	

—	
—	
—	
—	
—	
—	
—	

—
—
—
—
—
—
—

	20W/6T5/Q/GX32d-2/PH	
	27W/7T5/Q/GX32d-3/PH	

CFQ20W/GX32d	
CFQ27W/GX32d	

YES	
YES	

—	
—	

—	
—	

PL-C 15MM/22W
PL-C 15MM/28W

	

CFT13W/2GX7	

NO	

—	

Twin, 2-Pin

Quad, 2-Pin

Quad, 2-Pin

OR

Quad, 4-Pin

Square, (2D)

T5 Quad, 2-Pin
13W/6T4/T/2GX7	

CF 13DS/E	

—

Twin T4, 4-Pin
	 18-20W/9T5/T/2G11/PH-RS	
FT18W/2G11	
NO	
F18 BX	
FT 18DL	
—
	 18W/10T5/T/2G11/RS	
FT18W/2G11/RS	
NO	
F18 BX/RS	
FT 18DL/RS	
PL-L 18W
	
18W/5T5/T/2G10	
CFM18W/2G10	
NO	
—	
CF 18DF	
—
	 24-27W/13T5/T/2G11/PH-RS	FT24W/2G11/RS	
NO	
F27 BX/RS	
FT 24DL	
PL-L 24W
	
24W/7T5/T/2G10	
CFM24W/2G10	
NO	
—	
CF 24DF	
—
36-39W/16T5/T/2G11/PH-RS	FT36W/2G11/RS	
NO	
F39 BX/RS	
FT 36DL	
PL-L 36W
	36W/9T5/T/2G10	CFM36W/2G10	
NO	
—	
CF 36DF	
—
	
40W/22T5/T/2G11/RS	FT40W/2G11/RS	
NO	
F40 BX/RS	
FT 40DL/RS	
PL-L 40W/RS
	50W/22T5/T/2G11/RS	FT50W/2G11/RS	
NO	
F50 BX/RS	
—	
PL-L 50W/RS
	55W/21T5/T/2G11	FT55W/2G11	
NO	
F55 BX	
FT 55DL	
—
	80W/22T5/T/2G11	FT80W/2G11	 NO	—	
—	 PL-L 80W
Long Twin T5, 4-Pin
	 18W/5T4/M/GX24d-2	
CFM18W/GX24d	
YES	
—	
CF 18DT	
—
	 26W/6T4/M/GX24d-3	
CFM26W/GX24d	
YES	
—	
CF 26DT	
—
	
	
	
	
	
	
	

13W/5T4/M/GX24q-1	
18W/5T4/M/GX24q-2	
26W/6T4/M/GX24q-3	
32W/6T4/M/GX24q-3	
42W/7T4/M/GX24q-4	
57W/7T4/M/GX24q-5	
70W/8T4/M/GX24q-6	

CFM13W/GX24q	
CFM18W/GX24q	
CFM26W/GX24q	
CFM32W/GX24q	
CFM42W/GX24q	
CFM57W/GX24q	
CFM70W/GX24q	

NO	
NO	
NO	
NO	
NO	
NO	
NO	

F13 TBX/4P	
F18 TBX/4P	
F26 TBX/4P	
F32 TBX/4P/EOL	
F42 TBX/4P/EOL	
F57 QBX/4P/EOL	
F70 QBX/4P/EOL	

CF 13DT/E	
CF 18DT/E/IN	
CF 26DT/E/IN	
CF 32DT/E/IN	
CF 42DT/E/IN	
CF 57DT/E/IN	
—	

—
PL-T 18W/4P
PL-T 26W/4P
PL-T 32W/4P
PL-T 42W/4P
—
—

FPC22	
FPC40	
FPC55/HO	

FC9T5 22W
FC12T5 40W
FC12T5 55W

Multiple, 4-Pin
	—	
	
—	
	—	

FC9T5-22W/2GX13	NO	 —	
FC12T5-40W/2GX13	
NO	
—	
FC12T5-55W/2GX13	NO	 —	

T5 Circular, 4-Pin
FOR MORE INFORMATION CALL

PAGE 3-5

1-800-BALLAST
(225-5278)

Compact Fluorescent

Multiple, 2-Pin

Specifications
TYPICAL SPECIFICATIONS
FOR ELECTRONIC COMPACT FLUORESCENT BALLASTS:
•	 Ballasts shall be constructed of metal housing to meet plenum and construction code requirements while providing maximum heat transfer
	 without extra grounding wires for extended ballast life.
•	 Ballasts shall be constructed using dual entry color coded wire trap terminals for wiring accuracy and ease of installation.
•	 Ballasts shall be Programmed Start.
•	 Ballasts shall have a minimum Rh/Rc of 4.25 each time the lamps are started.
•	 Ballasts shall have a maximum ionization current (Glow Current) of 25 milliamps during preheating interval.
•	 Ballasts shall operate from 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ± 10% (Voltage &
	 Frequency) with no damage to the ballasts.
•	 Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 50 kHz to minimize interference with infrared
	 control systems.
•	 Ballasts shall have a minimum starting temperature of 0°F (-18°C) for the primary lamp application.
•	 Ballasts shall tolerate operation in ambient temperatures up to 140°F (55°C) without damage.
•	 Ballasts shall have a maximum case temperature test point of 75°C printed on the label for easy fixture testing and trouble shooting.
•	 Ballasts shall support 12’ lead length remote mounting for the primary lamp.
•	 Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (radiated).
•	 Ballasts shall provide transient immunity as recommended by ANSI C82.11-2011.
•	 Ballasts shall incorporate end of lamp life shutdown circuitry for end of lamp life protection.
•	 Ballasts shall allow for re-lamping without the need to cycle power.
•	 Ballasts shall operate lamps with no visible flicker (<3% flicker index).
•	 Ballasts shall tolerate sustained open and short circuit output conditions without damage.
•	 Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor and/or CSA certified for both US and Canadian application.
•	 Ballasts shall be UL 935 Type CC rated to reduce arcing caused by loose connections or improper lamp-pin to lampholder contact.
•	 Ballasts shall be UL 2043 certified for use in plenums and marked on label as “Suitable for Air Handling Spaces”.
•	 Ballasts shall be quiet Class A sound rating.
•	 Ballasts shall have a Ballast Factor for primary lamp application greater than .95 per ANSI C82.11-2011.

Compact Fluorescent

•	 Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.
•	 Ballasts shall have a Power Factor greater than .98 for the primary lamp application.
•	 Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and
	 ANSI C82.11-2011.
•	 The ballasts shall not have any PCB’s.
•	 The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from
	 date of manufacture.
•	 Manufacturer shall have been manufacturing electronic ballasts for at least thirty years.
•	 Ballasts shall be manufactured in an ISO 9001 / ISO 9002 Certified Facility in North America.
•	 Ballasts shall be manufactured by Universal Lighting Technologies.

FOR MORE INFORMATION CALL

PAGE 3-6

1-800-BALLAST
(225-5278)

Understanding Universal Part Numbers

ELECTRONIC
Our nomenclature for electronic CFL ballasts follows
the system already in place for other Universal electronic
ballasts. The exceptions are that the model number
prefix for compact fluorescent is a C rather than a B.

Example:Electronic C240PUNVHP-BOOOC
Ballast Type: C — CFL Electronic Ballast
Lamp Qty: 2
Lamp Type: 40W TT5, 4 Pin (FT40W/2611)
P: Programmed Start
Voltage: UNV 120 to 277 volts
HP-B: High Performance <10%; low profile can
000: Color—Black
C: Packaging container style—Carton Pack

Lamp Wattage

UNV or 347V

Color: 001 - White
000 - Black

CXXX XX XXX XXX XXX X
# of SR -Series,
lamps
Rapid Start
P - Programmed Start

BE - Bottom Exit
ME - Multi Exit
MES - Multi Exit with Studs

120V, 277V
347V, UNV
Lamp Wattage* (120-277)

Color: 001 - White
000 - Black

CXXX X XXX XXX XXX
# of
lamps

No suffix - P
P - Programmed
Start
I - Instant Start

C -Carton
T -Tray Pack
I -Individual
K -Replacement Mult-E Kit

X

BE - Bottom Exit
ME -Multi Exit
MES -Multi Exit with Studs
HP-B - Low Profile
RH - Reduced Harmonics

C -Carton
T -Tray Pack
I -Individual
K -Replacement Mult-E Kit

Example: C213UNVMES000C*
Ballast Type: C
Lamp Quantity: 2
Lamp Type: 13W Quad, 4 Pin (CFQ13W/G24q)
Voltage: UNV 120 to 277 volts
MES: Multi-exit connection, with studs
000C: Color—Black
C: Packaging container style—Carton Pack
*Exception is C2642, which does not distinguish number of lamps. See catalog.
Compact Fluorescent

FOR MORE INFORMATION CALL

PAGE 3-7

1-800-BALLAST
(225-5278)

Compact Fluorescent

Notes

FOR MORE INFORMATION CALL

PAGE 3-8

1-800-BALLAST
(225-5278)

MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS FOR TWIN, QUAD
AND MULTIPLE LAMPS
13-26 WATTS
QUICK
REFERENCE

Nominal lamp watts
and configuration

Lamp Type
13 Watts
CFT13W/GX23
OR
CFQ13W/GX23
Lamp Type
13 Watts
CFQ13W/G24q
OR
CFM13W/GX24q

OR

OR

Lamp Type
13 Watts
CFT13W/2GX7
Lamp Type
18 Watts
CFQ18W/G24q
OR
CFM18W/GX24q

Lamp Type
26 Watts
CFQ26W/G24q
OR
CFM26W/GX24q

OR

OR

Twin or
Quad, 2-Pin
U.S. type

• Ideal for downlights & wall sconces
• E lectronic models feature universal input
voltage from 120V to 277V. 347V models are
also available.
• E lectronic models feature programmed start
for excellent lamp performance & auto reset
shutdown circuit

13-26 WATTS

	 Lead Configuration 	
	Mag	 Qty				
Line	 Starting		 Min Start		
	 or	 of	 Line	 Catalog	 Input	 Current	 Current	 Ballast	 Temp	 Power		 Side	 Multi	 Multi	 Starting		 Wir
	 Elec	 Lamps	 Volt	 Number	 Watts	 Amps	 Amps	 Factor	 (F/C)	 Factor	 THD	 Exit	 Exit	 Exit Studs	 Method✿	Dim	Diag
Electrical Characteristics - 60 Hz
❍	M	 1	 120	 CF1320H2P ■	16	 0.24	 0.30	 0.85	25°/-4°	>.50	 <15%	X	 —	
—	
PH	 B10	1

■H
	 2 indicates clamped & covered core & coil with mounting feet.
◆ Add following suffix for complete catalog #: “BE” for Bottom Exit connectors,
	 “ME” for Multi Exit connectors, or “MES” for Multi Exit with 2” OC screw studs.
❍ Not approved for use in hazardous locations.
rAdd “000K” suffix for Mult-E Kit. For Distribution only.
✱ Add “001K” suffix for Mult-E Kit. For Distribution only.

PAGE 3-9

All ballasts are UL listed, CSA approved and
designated Class P (thermally protected).

See page 3-11 for Dimensions
and Wiring Diagrams.

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Compact Fluorescent

	
	120	
	 	0.15	
>.98 <10%
E	1
C213UNVMEr 18
——	 1.00	0°/-18°	
	
		 X	 X	
PS	 C3	3
			
277			0.07							>.95	<15%
Quad or
	
	120	
	
	0.26	
Multiple,
E	2
C213UNVMEr 30
——	 1.00	0°/-18°	 >.98	 <10%		
X	
X	
PS	 C3	 4
4-Pin
			 277			 0.11
	 	1	
	18	
0.06	
——	
1.00	
	3
E
347	C213/347ME✱
0°/-18°	>.98	 <10%		 X	
X	
PS	 C3
		
2			
33	
0.10	 ——	 0.98										 4
	
	120	
	
0.12	
<10%
E	1
CT213UNVME 15	
——	0.98	
0°/-18°	 >.98	
		 X	 X	
PS	 C3	3
			
277			0.06								<12%	
Twin T4,
4-Pin
	 	
	120
	 	0.22	
	
	
E
2
	CT213UNVME 26
——	0.98 0°/-18°	>.98	 <10%		 X	
X	
PS	 C3 4
277			0.10
	 	
   	
	
	120	
	 	0.16	
>.98 <10%
E	1
C218UNV ◆r 19
——	1.00	
0°/-18°	
	
		 X	 X	
PS	 C3	3
			
277			0.07							>.95	<15%
Quad or
	
	120	
	 	0.30	
Multiple, 4-Pin E	2
C218UNV◆r 35
——	0.95	
0°/-18°	 >.98	<10%		 X	 X	
PS	 C3	4
			 277			 0.13
	 	1	
	21	 0.06	 ——	 1.00	
	3
E
347	C218/347ME✱
0°/-18°	 >.98	<10%		 X	 X	
PS	 C3
		
2			
38	
0.11	 ——	 0.98										 4
	
	120	
	 	0.25	
E	1
C2642UNV◆r 28
——	1.02	
0°/-18°	 >.98	<10%		 X	 X	
PS	 C3	3
Quad or
			 277			 0.11
Multiple,
	
	120	
	 	0.47	
4-Pin
E	2
C2642UNV◆r 56
——	0.98	
0°/-18°	 >.98	<10%		 X	 X	
PS	 C3	4
			 277			 0.21
	 	1	 	
	31	 0.09	 ——	 1.02	
	3
E
347 C2642/347ME✱
0°/-18°	 >.98	<10%		 X	 X	
PS	 C3
		
2			
57	
0.17	 ——	 0.98										 4
	
	120	
	 56	
0.46	
E	2
C242UNV◆
——	1.02	
0°/-18°	 >.95	<10%		 X	 X	
PS	 C4	4
			 277		
55	 0.20
	E	 2	 347	 C242/347ME 	 44	
0.14	 ——	 1.02	 0°/-18º	 >.98	 <10%		
X	
X	
PS	 C4	 4

✿ PH = Preheat; PS = Programmed Start

	
	

OR

TWIN, QUAD
& MULTIPLE
LAMPS

• Ideal for downlights, surface mount &
outdoor fixtures
• E lectronic models feature universal input
voltage from 120V to 277V. 347V models
are also available.
• E lectronic models feature programmed
start for excellent lamp performance
& auto reset shutdown circuit

MULTIPLE
LAMPS
32, 42, 57 & 70 WATTS

QUICK
REFERENCE

Nominal lamp watts
and configuration

Lamp Type
32 Watts
CFM32W/GX24q

Multiple, 4-Pin
Lamp Type
42 Watts
CFM42W/GX24q

Multiple, 4-Pin
Lamp Type
57 Watts
CFM57W/GX24q

Multiple, 4-Pin

Compact Fluorescent

Lamp Type
70 Watts
CFM70W/GX24q

ELECTRONIC
COMPACT FLUORESCENT
BALLASTS FOR MULTIPLE LAMPS
32, 42, 57 & 70 WATTS

	 Lead Configuration 	
	Mag	 Qty				
Line	 Starting		 Min Start		
	or	 of	 Line	 Catalog✪	 Input	 Current	 Current	 Ballast	 Temp	 Power		 Side	 Multi	 Multi	 Starting		 Wir
	 Elec	 Lamps	 Volt	
Number	
Watts	 Amps	 Amps	 Factor	 (F/C)	 Factor	 THD	 Exit	 Exit	 Exit Studs	 Method✿	Dim	Diag
Electrical Characteristics - 60 Hz
	
	120	
	
	0.30	
E	1
C2642UNV◆r 36
——	 1.00	0°/-18º	 >.98	 <10%		 X	
X	
PS	 C3	3
			 277			 0.13
✱
	E	 1	 347	C2642/347ME 	36	 0.11	 ——	 0.98	0°/-18º	 >.98	<10%		 X	 X	
PS	 C3	3
	
	120	
	69	0.58	
E	2
C242UNV◆
——	 1.00	0°/-18º	 >.98	 <10%		 X	
X	
PS	 C4	4
			 277		
67	 0.26
	E	 2	 347	 C242/347ME	 62	 0.19	 ——	 1.00	0°/-18º	 >.98	<10%		 X	 X	
PS	 C4	4
	
	120	
	0.41	
E	1
C2642UNV ◆r	48
——	 0.98	0°/-18º	 >.98	 <10%		
			 277			 0.18	
	E	 1	 347	C2642/347ME✱	50	 0.15	 ——	 1.00	0°/-18º	 >.98	<10%		
	
	120	
	
	0.40	
E	1
C242UNV◆
45
——	 1.00	0°/-18º	 >.93	 <10%		
			 277		
	 0.18
	
	120	
91	0.76	
E	2
C242UNV ◆	
——	 0.98	0°/-18º	 >.98	 <10%		
			 277		
90	 0.32	
	E	 1	 347	 C242/347ME	42	0.13	——	1.00	
0°/-18º	 >.98	<10%		
	E	 2	 347	 C242/347ME	80	0.25	——	0.98	
0°/-18º	 >.98	<10%		
	
	120	
58	0.52	
E	1
C242UNV ◆ 	
——	 1.00	0°/-18º	 >.98	 <10%		
			 277		
57	 0.21	
	E	 1	 347	 C242/347ME	 61	 0.18	 ——	 1.00	0°/-18º	 >.98	 < 10%		

	
	120	
73	0.61
>.98
E	1
C242UNV ◆ 	
	 ——	 1.00	0°/-18º	
	<10%		
			 277		
72 	 0.27 				
>.95
	E	 1	 347	 C242/347ME	 74	 0.21	 ——	 1.00	0°/-18º	 >.98	 < 10%		

X	

X	

PS	 C3	 3

X	

X	

PS	 C3	3

X	

X	

PS	 C4	3

X	

X	

PS	 C4	 4

X	
X	

X	
X	

PS	 C4	3
PS	 C4	4

X	

X	

PS	 C4	 3

X	

X	

PS	

X	

X	

PS	 C4	3

X	

X	

PS	

C4	 3

C4	 3

Multiple, 4-Pin

	

	

✿ PS = Programmed Start
		◆ Add following suffix for complete catalog #:
“BE”suffix for Bottom Exit connectors, “ME” for
		 multi-exit connectors, or “MES” for multi exit connectors
		 with 2” O.C. screw studs.
      rAdd “000K” suffix for Mult-E Kit. For Distribution only.
✱ Add “001K” suffix for Mult-E Kit. For Distribution only.

All ballasts are UL listed, CSA approved and
designated Class P (thermally protected), Type HL.

See page 3-11 for Dimensions
and Wiring Diagrams.
FOR MORE INFORMATION CALL

PAGE 3-10

1-800-BALLAST
(225-5278)

TWIN, TRIPLE,
QUAD &
MULTIPLE
LAMPS

MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS
WIRING DIAGRAMS AND DIMENSIONS
REFERENCE DRAWING FOR B10
C

WIRING DIAGRAMS
F

A

Install in accordance with
National Electrical Code.

G

B
D
E

	Dwg.	

A	

B	

D	

E

	B10	 1.48”	 1.30”	 2.68”	 3.08”

Black

Leadless-Poke-in wire connection

Black
Line

REFERENCE DRAWING FOR C3
C

Black

BALLAST

White
Green

BALLAST

Red
Red
Blue
Blue

DIAGRAM 3

DIAGRAM 1

Ballast should be grounded
F

A

G

B
D
E

	Dwg.	

A	

B	

C	

D	

E	

F	

G
Black

	C3	 2.31”	1.00”	4.25”	4.61”	4.94”	 0.98”	1.00”

White
Green

Leadless-Poke-in wire connection

BALLAST

Red
Red
Yellow
Yellow
Blue
Blue

DIAGRAM 4
Series lamp operation
Ballast should be grounded

REFERENCE DRAWING FOR C4

A	

B	

C	

D	

E	

F	

G

Compact Fluorescent

	Dwg.	

	C4	 2.98”	1.00”	4.25”	 4.61”	4.94”	1.55”	1.00”
Leadless-Poke-in wire connection

Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances

PAGE 3-11

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

2D
LAMPS

• Ideal for surface mount fixtures
•U
 niversal input voltage from 120V to 277V.
347V models are also available.
• P rogrammed start for excellent lamp performance
& auto reset shutdown circuit

10, 16 & 21
WATTS

10, 16 AND 21 WATTS
QUICK
REFERENCE

Nominal lamp watts
and configuration

Lamp Type
10 Watts
CFS10W/GR10q

2D, 4-Pin
Lamp Type
16 Watts
CFS16W/GR10q

2D, 4-Pin
Lamp Type
21 Watts
CFS21W/GR10q

2D, 4-Pin

	

Compact Fluorescent

ELECTRONIC COMPACT
FLUORESCENT BALLASTS
FOR 2D LAMPS

	

	 Lead Configuration 	
	Mag	 Qty				 Line	 Starting		 Min Start		
	 or	 of	 Line	 Catalog✪	 Input	 Current	 Current	 Ballast	 Temp	 Power		 Side	 Multi	 Multi	 Starting		 Wir
	 Elec	 Lamps	 Volt	 Number	 Watts	 Amps	 Amps	 Factor	 (F/C)	 Factor	 THD	 Exit	 Exit	 Exit Studs	 Method✿	Dim	Diag
Electrical Characteristics - 60 Hz
	
	 120	
	 	0.12	
	
>.98 <10%
E	1
C213UNVMEr 15
—— 1.02	 0°/-18º	
	
	—	 X	
X	
PS	 C3	2a
			
277			
0.06				
>.95	<15%		
	
	 120	
	 	0.22	
	
>.98 <10%
E	2
C213UNVMEr 26
—— 1.02	 0°/-18º	
	
	—	 X	
X	
PS	 C3	3a
			 277			 0.10				
>.95	<15%
✱
	 E	 1	 347	C213/347ME 	16	 0.05	 ——	 1.02 0°/-18º	 >.95	<10%	—	 X	
X	
PS	 C3	2a
	
	 E	 2	 347	C213/347ME✱	28	 0.08	 ——	 1.02 0°/-18º	 >.95	<10%	—	 X	
X	
PS	 C3	3a
	
	
	
	
E	1
			
	E	 1	
	
	
E	2
			
	E	 2	

120	
	0.15	
C213UNVMEr	19
——	 0.95	 0°/-18º	
277			
0.07				
✱
347	 C213/347ME 	20	 0.06	 ——	 0.95 0°/-18º	
	
	
	0.28	
120	
——	 0.95	 0°/-18º	
C213UNVMEr 33
277			
0.12				
347	 C213/347ME✱	34	 0.10	 ——	 0.95 0°/-18º	
	

>.98 <10%
	
	—	
>.95	<15%
>.98	<10%	 —	
>.98
	<10%	 —	
>.95
>.98	<10%	 —	

	
	
	120	
	0.18	
E	1
C218UNV◆r	24
——	 0.98	 0°/-18º	
			 277			
0.08				
✱
	E	 1	 347	C218/347ME 	21	 0.06	 ——	 0.98 0°/-18º	
	
	120	
	0.37	
	
	E	 2
C218UNV◆r	43
——	 0.95	 0°/-18º
			 277			
0.16				
	E	 2	 347	C218/347ME✱	39	 0.12	 ——	 0.95 0°/-18º	
	
	

>.98 <10%
	
	—	
>.95	<15%	
>.98	<10%	—	
>.98 <10%
	
	—	
>.95	<15%
>.98	<10%	—	

✿ PS = Programmed Start
◆ Add following suffix for complete catalog #: “BE” for Bottom
		Exit connectors, "ME" for Multi Exit connectors, or "MES" for
Multi	Exit with 2" OC screw studs.
    rAdd “000K” suffix for Mult-E Kit. For Distribution only.
✱ Add “001K” suffix for Mult-E Kit. For Distribution only.

X	

X	

	
PS	 C3	2a

X	

X	

PS	 C3	2a

X	

X	

PS	 C3	3a

X	

X	

PS	 C3	3a

X	

X	

PS	 C3	2a

X	

X	

PS	 C3	2a

X	

X	

PS	 C3	3a

X	

X	

PS	 C3	3a

All ballasts are UL listed, CSA approved and
designated Class P (thermally protected), Type HL.

See page 3-14 for Dimensions
and Wiring Diagrams.

PAGE 3-12

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

ELECTRONIC COMPACT
FLUORESCENT BALLASTS
FOR 2D LAMPS
QUICK
REFERENCE

Nominal lamp watts
and configuration

Lamp Type
28 Watts
CFS28W/GR10q

2D, 4-Pin
Lamp Type
38 Watts
CFS38W/GR10q

2D
LAMPS

• Ideal for surface mount fixtures
•U
 niversal input voltage from 120V to 277V.
• Programmed start for excellent lamp
performance & auto reset shutdown circuit

28 & 38
WATTS

	 Lead Configuration 	
	Mag	 Qty				
Line	 Starting		 Min Start		
	 or	 of	 Line	 Catalog✪	 Input	 Current	 Current	 Ballast	 Temp	 Power		 Side	 Multi	 Multi	 Starting		 Wir
	 Elec	 Lamps	 Volt	
Number	 Watts	 Amps	 Amps	 Factor	 (F/C)	 Factor	 THD	 Exit	 Exit	 Exit Studs	 Method✿	Dim	Diag
Electrical Characteristics - 60 Hz
	
	120	
	0.27	
E	1
C2642UNV◆✱	31
——	0.95	
0°/-18º	 >.95	<10%	 —	X	 X	 PS	 C3	2a
			 277			 0.12	
✱
	E	 1	 347	C2642/347ME 	33	 0.10	 ——	 0.95	0°/-18º	 >.95	<10%	 —	 X	
X	
PS	 C3	2a
	
	120	
64	0.54	
◆
E	2
C242UNV 	
——	 1.00	 0°/-18º	 >.97	 <10%	 —	 X	
X	
PS	 C4	3a
			 277		
63	 0.24	
	E	 2	 347	 C242/347ME	 60	 0.18	 ——	 1.00	0°/-18º	 >.98	<10%	 —	 X	
X	
PS	 C4	3a
	
	
	120	
	0.27	
E	1
C2642UNV◆r	33
——	0.80	
0°/-18º	
			 277			 0.12

✿ PS = Programmed Start
◆ Add following suffix for complete catalog #: “BE” for Bottom
		Exit connectors, “ME” for Multi Exit connectors, or “MES” for
Multi E
	 xit with 2” OC screw studs.
	
    rAdd “000K” suffix for Mult-E Kit. For Distribution only.
2D,
4-Pin
✱
	
Add “001K” suffix for Mult-E Kit. For Distribution only.

>.95	<10%	 —	 X	

X	

PS	 C3	2a

All ballasts are UL listed, CSA approved and
designated Class P (thermally protected), Type HL.

Compact Fluorescent

See page 3-14 for Dimensions
and Wiring Diagrams.
FOR MORE INFORMATION CALL

PAGE 3-13

1-800-BALLAST
(225-5278)

ELECTRONIC COMPACT FLUORESCENT
BALLASTS FOR 2D LAMPS

2D
LAMPS

WIRING DIAGRAMS AND DIMENSIONS

REFERENCE DRAWING FOR C3
C

WIRING DIAGRAMS
F

A

Install in accordance with
National Electrical Code.

G

B
D
E

	Dwg.	

A	

B	

C	

D	

E	

F	

G

Black

	C3	 2.31”	1.00”	4.25”	4.61”	4.94”	 0.98”	 1.00”

White
Green

BALLAST

Leadless-Poke-in wire connection

Red
Red
Blue
Blue

DIAGRAM 2a

REFERENCE DRAWING FOR C4

Black
White
Green

BALLAST

Red
Red
Yellow
Yellow
Blue
Blue

	Dwg.	

A	

B	

C	

D	

E	

F	

DIAGRAM 3a
Series lamp operation

G

	
C4	2.98”	1.00”	4.25”	4.61”	4.94”	1.55”	1.00”
Leadless-Poke-in wire connection

Compact Fluorescent

Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances

FOR MORE INFORMATION CALL

PAGE 3-14

1-800-BALLAST
(225-5278)

ELECTRONIC COMPACT
FLUORESCENT BALLASTS
22, 40 & 55 WATTS

QUICK
REFERENCE

Nominal lamp watts
and configuration

Lamp Type
22 Watts
FC9T5-22W

T5 CIRCULAR

Lamp Type
40 Watts
FC12T5-40W

T5 CIRCULAR
Lamp Type
22 & 40 Watts
FC9T5-22W &
FC12T5-40W

T5 CIRCULAR
Lamp Type
55 Watts
FC12T5-55W

• Electronic models feature programmed
start for excellent lamp performance
& auto reset shutdown circuit

22, 40 & 55 WATTS

	 Lead Configuration 	
	Mag	 Qty				
Line	 Starting		 Min Start		
	 or	 of	 Line	
Catalog✪	 Input	 Current	 Current	 Ballast	 Temp	 Power		 Side	 Multi	 Multi	 Starting		 Wir
	 Elec	 Lamps	 Volt	
Number	
Watts	 Amps	 Amps	 Factor	 (F/C)	 Factor	 THD	 Exit	 Exit	 Exit Studs	 Method✿	Dim	Diag
Electrical Characteristics - 60 Hz
	E	 1	 347	C2642/347ME✱	26	 0.08	 ——	 0.98	0°/-18º	
	
	120	
	0.21	
E	1
C2642UNV◆r	25
——	 1.00	 0°/-18º	
			 277			 0.10
	E	 2	 347	 C242/347ME	 47	 0.14	 ——	 1.05	0°/-18º	
1.05	 0°/-18º	

	
	120	
	
	0.42	
E	2
C242UNV◆
50
——	
			 277			 0.19

	E	 1	 347	C2642/347ME✱	 40	0.12	——	0.98	
0°/-18º	
	
	0.35	
	
	120	
❍ E	1
——	 0.98	 0°/-18º	
C2642UNV◆r 42
			 277			 0.16	
	E	 2	 347	 C242/347ME	 71	 0.22	 ——	 0.98	0°/-18º	
	
	120	
80	0.65	
❍ E	2
C242UNV◆	
——	 0.98	 0°/-18º	
			 277		
79	 0.29
	
	120	
	
	
	
E	1+1
C242/347ME 59 0.18 ——	
			 277			
	
	120	
66	0.54	
E	1+1
C242UNV◆	
——	
			 277		
64	 0.24

X	

X	

PS	

C3	 2b

>.98	 <10%	 ––	

X	

X	

PS	

C3	 2b

>.98	 <10%	 ––	

X	

X	

PS	

C4	 1b

>.95	 <10%	 ––	

X	

X	

PS	

C4	 1b

>.98	<10%	 ––	 X	

X	

PS	 C3	2b

>.98	 <10%	 ––	

X	

PS	

>.98	<10%	 ––	 X	

X	

PS	 C4	1b

>.98	 <10%	 ––	 X	

X	

PS	 C4	1b

0.98	 0°/-18º	

>.98	 <10%	 ––	 X	

X	

PS	 C4	1b

0.98	 0°/-18º	

>.97	 <10%	 ––	 X	

X	

PS	 C4	1b

	120	
	0.45	
	E	 1
B2 54PUNV-D	 55
——	 1.00	 -20/-29	
			 277			
0.20				
	120	
	0.45	
	E	 1
B254PUNVHB-D	55
——	 1.00	 -20/-29	
			 277			
0.20				
	120	
51	0.43	
	E	 1
B254PUNVPL-A	
——	 1.00	 -20/-29	
			 277		
50	 0.20				
	 120	
51	0.43	
	E	 1
B254PUNVPLHBA	
——	 1.00	 -20/-29	
			 277		
50	 0.20				
	120	
107	0.88	
	E	 2
B254PUNV-D	
——	 1.00	 -20/-29	
			 277		
104	 0.38				
	120	
107	0.88	
	E	 2
B254PUNVHB-D	
——	 1.00	 -20/-29	
			 277		
104	 0.38				
	120	
92	0.77	
	E	 2
B254PUNVPL-A	
——	 0.96	 -20/-29	
			 277		
91	 0.34				
92	0.77	
	 120	
B254PUNVPLHBA	
——	 0.96	 -20/-29	
	E	 2
			 277		
91	 0.34				

PAGE 3-15

>.98	 <10%	 ––	

>.99
	
>.96
>.99
	
>.96
>.99
	
>.91
>.99
	
>.91
>.99
	
>.98
>.99
	
>.98
>.99
	
>.97
>.99
	
>.97

X	

C3	 2b

<10%	 X	

—	

—	

PS	

-D	 2b

<10%	 X	

—	

—	

PS	

-D	 2b

<10%	 X	

—	

—	

PS	

-A	 1b

<10%	 X	

—	

—	

PS	

-A	 1b

<10%	 X	

—	

—	

PS	

-D	 1b

<10%	 X	

—	

—	

PS	

-D	 1b

<10%	 X	

—	

—	

PS	

-A	 1b

<10%	 X	

—	

—	

PS	

-A	 1b

Compact Fluorescent

T5 CIRCULAR

T5
CIRCULAR
LAMPS

• Ideal for surface mount fixtures
• E lectronic models feature universal input
voltage from 120V to 277V. 347V models
are also available.

LONG TWIN
T5 LAMPS
18, 24/27 WATTS

QUICK
REFERENCE

Nominal lamp watts
and configuration

Lamp Type
18 Watts
FT18W/2G11/RS

• Ideal for track light & surface mount fixtures
• Electronic models feature universal input
voltage from 120V to 277V. 347V models are also
available
• Electronic models feature rapid and programmed
start for excellent lamp performance & auto reset
shutdown circuit

ELECTRONIC COMPACT
FLUORESCENT BALLASTS FOR
LONG TWIN T5 LAMPS
18 AND 24/27 WATTS (BIAX, DULUX L AND PLL)

	 Lead Configuration 	
	Mag	 Qty				 Line	 Starting		 Min Start		
	 or	
of	 Line	 Catalog✪	 Input	 Current	 Current	 Ballast	 Temp	 Power		 Side	 Multi	 Multi	 Starting		 Wir
	 Elec	 Lamps	 Volt	
Number	 Watts	 Amps	 Amps	 Factor	 (F/C)	 Factor	 THD	 Exit	 Exit	 Exit Studs	 Method✿	Dim	Diag
Electrical Characteristics - 60 Hz
	
	120	
	
	0.19	——	
	 —	 X	
X	
PS	 C3	21
E	1
CT218UNVME 23
1.00	 0°/-18º	 >.95	 <10%
	 		 277	
		
0.07	 ——	
	
	
	
	 —	 X	
X	
PS	 C3	21
	 		 120	
	
43	 0.37	 ——	
	
	
		
—	 X	
X	
PS	 C3	20
E	2
CT218UNVME
0.98 0°/-18º	 >.98 <10%
	
	277	
	42	 0.16	 ——	
	
	
	 —	 X	
X	
PS	 C3	20
	

Long Twin T5,
4-Pin

	
	120	
	0.23	
>.98 <10%
B224PUNV-C 	 27
——	 1.05	 0°/-18º	
	
	X	
			
277			
0.10				
>.95	<15%
✱
	 E	
1	 347	C2642/347ME 	29	 0.09	 ——	 0.90	 0°/-18º	 >.95	<10%	—	
❍
0.22	
>.99
	120	
——	 1.01	 0°/-18º	
	<10%	—	
	E	 1
C2642UNVr 	 26	
			
277		
	
0.10				
>.95	
	120	
52
0.43	
	E	 2
B224PUNV-C 	 	
——	 1.00	 0°/-18º	 >.98	 <10%	 X	
			 277		
51	 0.18					
Long Twin T5,
	E	 2	 347	C242/347ME	49	 0.14	 ——	 1.02	0°/-18º	 >.98	<10%	—	
4-Pin
	120	
51	0.43	
	 E	2
C242UNV◆ 	
——	1.02	
0°/-18º	 >.95	<10%	—	
			 277		
50	 0.19
	120	
47	0.40	
>.98
	E	 2
C2642UNVr 	
——	 0.98	 0°/-18º	
	<10%	—	
			
277		
49	 0.18				
>.99
Lamp Type
24/27 Watts
FT24W/2G11/RS

Compact Fluorescent

Lamp Type
24/27 Watts
CFM24W/2G10

❍ E	1

	120	
0.20	
1
B224PUNV-C 	 24	
——	 1.05	 0°/-18º	
			
277		
	
0.09				
	120	
48	0.40	
❍	E	 2
B224PUNV-C 	
——	 1.00	 0°/-18º	
			 277		
47	 0.17	

❍	E	

✿ PS = Programmed Start
		
❍ Not approved for use in hazardous locations
◆ Add following suffix for complete catalog #: “BE” for Bottom
		Exit connectors, “ME” for Multi Exit connectors, or “MES” for
T5 F-Lamp,
Multi Exit with 2” OC screw studs.
4-Pin
	
    rAdd “000K” suffix for Mult-E Kit. For Distribution only.
✱ Add “001K” suffix for Mult-E Kit. For Distribution only.
	

—	

—	

PS	 -C	43

X	

X	

PS	 C3	21

X	

X	

PS	 C3	 21

—	

—	

PS	

X	

X	

PS	 C4	20

X	

X	

PS	 C4	20

X	

X	

PS	 C3	 20

>.98 <10%
	
	X	 —	
>.95	<15%

—	

PS	 -C	43

>.98	 <10%	 X	

—	

PS	

—	

-C	 27

-C	 29

All ballasts are UL listed, CSA approved and
designated Class P (thermally protected).

See pages 3-19 and 3-20 for
Dimensions and Wiring Diagrams.

FOR MORE INFORMATION CALL

PAGE 3-16

1-800-BALLAST
(225-5278)

ELECTRONIC
LONG TWIN T5 BALLASTS
36/39 AND 40 WATTS
(BIAX, DULUX L AND PLL)

LONG TWIN
T5 LAMPS

• Ideal for track light & surface mount fixtures
• New electronic 1 & 2 lamp models for 24 watt lamps
• Electronic models feature universal input voltage
from 120V to 277V. 347V models are also available.
• Electronic models feature programmed rapid start for
excellent lamp performance & auto reset shutdown circuit

36/39 & 40
WATTS

QUICK
REFERENCE

	 Lead Configuration 	
	Mag	 Qty				 Line	 Starting		 Min Start		
	 or	
of	 Line	 Catalog✪	 Input	 Current	 Current	 Ballast	 Temp	 Power		 Side	 Multi	 Multi	 Starting		 Wir
	 Elec	 Lamps	 Volt	
Number	 Watts	 Amps	 Amps	 Factor	 (F/C)	 Factor	 THD	 Exit	 Exit	 Exit Studs	 Method✿	Dim	Diag
Lamp Type
Electrical Characteristics - 60 Hz
36/39 Watts
	 		
120	
	
	 0.30	 ——	
	
	
>.98			
B224PUNV-C• 36
0.95	 0/-18	
	<10% X	
—	—
PS	 -C	43
FT36W/2G11/RS ❍	 E	1	277	
	 	
0.13	 ——	
>.95
	
		
	
	120	
	0.37	
>.99
❍ E	1
B254PUNV-D£ 	44
——	1.20	
-20/-29	
	<10%	X	 —	
—	
PS	 -D	43
			
277			
0.17				
>.94							
	
	120	
	0.37	
>.99
E	1
B254PUNVHB-D	44
——	1.20	
-20/-29	
	<10%	 X	 —	
—	
PS	 -D	 43
			
277			
0.17				
>.94
Long Twin T5, 	
	120	
46	0.38	
>.99
4-Pin
E	1
B254PUNVPL-A	
——	1.00	
-20/-29	
	<10%	 X	 —	
—	
PS	 -A	 A
			
277		
45	 0.18				
>.90
	
	120	
46	0.38	
>.99
E	1
B254PUNVPLHBA	
——	1.00	
-20/-29	
	<10%	 X	 —	
—	
PS	 -A	 A
			
277		
45	 0.18				
>.90
	
	120	
34	0.29	
	
>.99 < 10%	
	
C242UNV◆	
——	0.88 0/-18	
	
X	 X	
X	
PS	 C4	21
❍ E	1
			
277		
33	 0.14				
>.90	 < 20%
	 		
120	
	
71	 0.59	 ——	
	
	
>.98			
❍ E	2
B239PUNV-D•
0.97	 0/-18	
	<10% X	
—	—
PS	 -D	29
	
	277	
	 70 	 0.26	 ——	
>.95
	
		
	
	120	
89	0.70	
>.99
❍ E	2
B254PUNV-D	
——	1.10	
-20/-29	
	<10%	 X	 —	
—	
PS	 -D	 29
			
277		
83	 0.30				
>.97
	
	120	
89	0.70	
>.99
E	2
B254PUNVHB-D	
——	1.10	
-20/-29	
	<10%	 X	 —	
—	
PS	 -D	 29
			
277		
83	 0.30				
>.97
	
	120	
85	0.71	
0.98
>.99
E	2
B254PUNVPL-A	
——	
	 -20/-29	
	<10%	 X	 —	
—	
PS	 -A	 A
			 277		
83	 0.31		 0.96		
>.96
	
	120	
85	0.71	
0.98
>.99
E	2
B254PUNVPLHBA	
——	
	 -20/-29	
	<10%	 X	 —	
—	
PS	 -A	 A
			 277		
83	 0.31		 0.96		
>.96
	E	 2	 347	 C242/347•◆	64	 0.19	 ——	 0.90	 0/-18	 >.98	<10%	—	 X	
X	
PS	 C4	20
			 120		 ◆
	 0.57	 ——			
>.99
E	2
C242UNV• 64
0.83	 0/-18	
	<10% —	X	 X
PS	 C4	20
	
	277	
		
0.25 	 ——	
>.97
	
	

Nominal lamp watts
and configuration

Lamp Type
36/39 Watts
CFM36W/2G10

FOR MORE INFORMATION CALL

PAGE 3-17

1-800-BALLAST
(225-5278)

Compact Fluorescent

	 0.28	
>.98
	
	
	120	
B224PUNV-C•	 34
——	0.95	0/-18	
	<10%	 X
—	 —	
PS	 -C	43
E	1
			
277			
0.12				
>.95
	 	
	120	
	 	0.27	——	 	
	
	 	
	
	
	
	
	
E
1
C2642UNV◆r 32
0.98 0/-18	
>.98 <10% —
X
X
PS
C3 21
			 277			 0.12	 ——										
	
	120	
	
	0.28	
	
>.99
	
E	1
C242UNV◆ 33
——	0.98 0/-18	
	<15%	—	 X	
X	
PS	 C4	21
	 		
277			
0.14				
>.90
			 120	
	
68	 0.57	 ——	
	
	
	
T5 F-Lamp,
E	2
C242UNV•◆r
0.90	 0/-18	
>.95	<10% —	X	 X
PS	 C4	20
	
	277	
	67	 0.25	 ——	
	
	
4-Pin
	
Lamp Type
❍	E	 1	 120	 C240SI120RH	 43	 0.38	 ——	 1.02	50/10	
>.90	<20%	 X	 —	
—	
IS	 C6	12✛
40 Watts
>.90	<20%	 X	 —	
—	
IS	 C6	12✛
FT40W/2G11 ❍	E	 1	 277	 C240SI277RH	 43	 0.17	 ——	 1.02	50/10	
	
	120	
	41	 0.34	
E	1
C240PUNVHP-B
——	 1.00	 0/-18	
>.95	 <10%	 X	
—	
—	
PS	 -B	 21
			 277		 • 40	 0.15
	
	120	
	
	0.40	
>.99
E	1
C242UNV◆
47
——	 1.08	 0/-18	
	<10%	—	 X	
X	
PS	 C4	 21
			 277			 0.18				
>.97
❍
	120	
	76	 0.63	
Long Twin T5, 	
E	2
C240PUNVHP-B•
——	 0.90	 0/-18	
>.98	 <10%	 X	
—
—	
PS	 -B	20
4-Pin
❍			 277		
73	 0.27											
	
	
❍ E	 2	 120	C240SI120RH	70	 0.59	 ——	 0.88	50/10	
>.95	<20%	 X	 —	
—	
IS	 C6	 12
❍	E	 2	 277	 C240SI277RH	 70	 0.25	 ——	 0.88	50/10	
>.95	<20%	 X	 —	
—	
IS	 C6	 12
	
	120	
>.99
◆	 93	0.78	
E	2
C242UNV
——	 1.00	 0/-18	
	<10%	—	 X	
X	
PS	 C4	 20
			 277		
87	 0.34				
>.98
	E	 2	 120	 C340SI120RH	 78	 0.68	 ——	 0.99	50/10	 >.90	 <20%	 X	 —	
—	
IS	 C6	14 ✛
	E	 2	 277	 C340SI277RH	 77	 0.28	 ——	 0.99	50/10	 >.90	<20%	 X	 —	
—	
IS	 C6	14✛
	E	 3	 120	 C340SI120RH	 104	 0.88	 ——	 0.88	50/10	 >.95	<20%	 X	 —	
—	
IS	 C6	 14
	E	 3	 277	 C340SI277RH	 102	 0.37	 ——	 0.88	50/10	 >.95	<10%	 X	 —	
—	
IS	 C6	 14	
	E	 3	 347	 B332I347HP	 97	 0.28	 ——	 0.85	 0/-18	
>.99	<20%	 X	 —	
—	
IS	 ST	 6

ELECTRONIC
LONG TWIN
T5 LAMPS

• Ideal for track light & recessed fixtures
• Electronic models for 1, 2, 3 & 4 lamp applications
• Programmed Rapid & Instant Starting Options
• Models feature auto reset shutdown circuit

50, 55 & 80 WATTS

ELECTRONIC
LONG TWIN T5 BALLASTS
50, 55 AND 80 WATTS
(BIAX, DULUX L AND PLL)

m
QUICK
REFERENCE

Nominal lamp watts
and configuration

Lamp Type
50 Watts
FT50W/2G11

Compact Fluorescent

Long Twin T5,
4-Pin

Lamp Type
55 Watts
FT55W/2G11

Long Twin T5,
4-Pin

	 Lead Configuration 	
	Mag	 Qty				
Line	 Starting		 Min Start		
	 or	
of	 Line	 Catalog✪	
Input	 Current Current	 Ballast	 Temp	 Power		 Side	 Multi	 Multi	 Starting		 Wir
	 Elec	 Lamps	 Volt	
Number	
Watts	 Amps	 Amps	 Factor	 (F/C)	 Factor	 THD	 Exit	 Exit	 Exit Studs	 Method✿	Dim	Diag
Electrical Characteristics - 60 Hz
	
E	 1	 347	B254P347-D	58	0.17	——	1.12	
-20/-29	 >.95	<10%	X	 —	 —	
PS	 -D	43
	
	347	
	0.19	
>.95	<10%	
E	1
B254PHRVHB-E	65
——	 1.12	-20/-29	
X	 —	 —	
PS	 -E	42
			 480			 0.15				 >.90	<15%
	 	0.47	
>.99
	
	120	
——	 1.00	-20/-29	
	<10%	X	 —	 —	
PS	 -D	43
E	1
B254PUNV-D 57
			
277		
	 0.21				
>.96
	
	120	
	0.47	
>.99
E	1
B254PUNVHB-D 	57	 0.21				
——	 1.00	-20/-29	 >.96	<10%	X	 —	 —	
PS	 -D	43
			
277		
	
	120	
	
59	0.50	
>.99
E	1
B254PUNVPL-A1
——	 1.00	-20/-29	
	<10%	X	 —	 —	
PS	 -A	 A
			 277		
58	 0.22				 >.93
	
	120	
	59	0.50	
>.99
E	1
B254PUNVPLHBA1
——	 1.00	-20/-29	
	<10%	X	 —	 —	
PS	 -A	 A
			 277		
58	 0.22				 >.93
	
E	 2	 347	B254P347-D	106	0.31	——	1.10	
-20/-29	 >.98	<10%	X	 —	 —	
PS	 -D	27
	
	347	
	115	 0.33	
>.98
E	2
B254PHRVHB-E
——	 1.10	-20/-29	
	<10%	X	 —	 —	
PS	 -E	 41
			 480		
114	 0.25				 >.95
	
	120	
	 111	 0.93	
>.99
	
E	2
B254PUNV-D
——	 1.00	-20/-29	
	<10%	X	 —	 —	
PS	 -D	29
			
277		
108	 0.40 				
>.98
	111	 0.93	
>.99
	
	
	120	
B254PUNVHB-D
——	 1.00	-20/-29	
	<10%	X	 —	 —	
PS	 -D	29
E	2
			
277		
108	 0.40 				
>.98
	 112	0.95	
>.99
	
	120	
B254PUNVPL-A1
——	 0.93	-20/-29	
	<10%	X	 —	 —	
PS	 -A	 A
E	2
			 277		
108	 0.42				 >.97
	
1
12	0.95	
>.99
	
	120	
B254PUNVPLHBA1
——	 0.93	-20/-29	
	<10%	X	 —	 —	
PS	 -A	 A
E	2
			 277		
108	 0.42				 >.97
	
	120	
	179	 1.49	
>.98
E	3
B454PUNV-E
——	 1.13	-20/-29	
	<10%	X	 —	 —	
PS	 -E	 44
			 277		
177	 0.64				 >.95
	
	120	
179	1.49
>.98
E	3
B454PUNVHB-E	
	——	1.13	
-20/-29	 	<10%	X	 —	 —	
PS	 -E	 44
			 277		
177	 0.64				 >.95
	
159	1.34	
>.99
	
	120	
B454PUNVPL-E1
——	 0.91	-20/-29	
	<10%	X	 —	 —	
PS	 -E	 B
E	3
			 277		
157	 0.58			
>.97	
	
	
	120	
	
1
59	1.34	
>.99
E	3
B454PUNVPLHBE1
——	 0.91	-20/-29	
	<10%	X	 —	 —	
PS	 -E	 B
			 277		
157	 0.58				 >.97
	
	120	
240	1.98
E	4
B454PUNV-E	
	——	1.10	
-20/-29	
>.98	<10%	X	 —	 —	
PS	 -E	44
			 277		
235	 0.84
	
	120	
240	1.98
E	4
B454PUNVHB-E	
	——	1.10	
-20/-29	
>.98	<10%	X	 —	 —	
PS	 -E	44
			 277		
235	 0.84
	
209	1.76	
>.99
	
	120	
B454PUNVPL-E1
——	 0.91	-20/-29	
	<10%	X	 —	 —	
PS	 -E	 B
E	4
			 277		
203	 0.75			
>.98	
	
	
	120	
	209	1.76	
>.99
E	4
B454PUNVPLHBE1
——	 0.91	-20/-29	
	<10%	X	 —	 —	
PS	 -E	 B
			 277		
203	 0.75				 >.98
	
E	 1	 347	B254P347-D	57	0.17	——	0.92	
-20/-29	>.95	<10%	 X	 —	
—	
PS	 -D	 43
	
	347	
	0.19	
>.98	<10%	
E	1
B254PHRVHB-E	61 0.14				
——	 0.92	-20/-29	 >.90	<15%	 X	 —	 —	
PS	 -E	42
			
480			
	0.47	
>.99
	
	120	
——	 1.00	-20/-29	 >.96	<10%	X	 —	 —	
PS	 -D	43
E	1
B254PUNV-D 	56	 0.21				
			
277		
	
	120	
	0.47	
>.99
E	1
B254PUNVHB-D 	56	 0.21				
——	 1.00	-20/-29	 >.96	<10%	X	 —	 —	
PS	 -D	43
			
277		
	
	120	
	
	0.49	
>.99
E	1
B254PUNVPL-A1 58
——	 1.00	-20/-29	
	<10%	X	 —	 —	
PS	 -A	 A
			 277			 0.22				 >.93
	
	120	
	 	0.49	
>.99
E	1
B254PUNVPLHBA1 58
——	 1.00	-20/-29	
	<10%	X	 —	 —	
PS	 -A	 A
			 277			 0.22				 >.93
	
E	 1	 347	C242/347ME	43	0.13	——	0.83	0/-18	 >.99	<10%	—	 X	
X	
PS	 C4	21
	0.38	
>.99
	
	
	120	
——	 0.83	0/-18	 >.95							
	<10%	—	 X	
X	
PS	 C4	21
E	1
C242UNVu	46 0.17				
			
277			
1 Consult factory for availability

FOR MORE INFORMATION CALL

PAGE 3-18

1-800-BALLAST
(225-5278)

MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS

LONG TWIN
T5 LAMPS

DIMENSIONS
QUICK
REFERENCE

Nominal lamp watts
and configuration

Lamp Type
55 Watts
FT55W/2G11

Long Twin T5,
4-Pin

	 Lead Configuration 	
	Mag	 Qty				
Line	 Starting		 Min Start		
	 or	
of	 Line	 Catalog✪	
Input	 Current Current	 Ballast	 Temp	 Power		 Side	 Multi	 Multi	 Starting		 Wir
	 Elec	 Lamps	 Volt	
Number	
Watts	 Amps	 Amps	 Factor	 (F/C)	 Factor	 THD	 Exit	 Exit	 Exit Studs	 Method✿	Dim	Diag
Electrical Characteristics - 60 Hz
	
E	 2	 347	B254P347-D	102	0.30	——	0.90	
-20/-29	>.98	<10%	 X	 —	
—	
PS	 -D	 27
	
	347	
	109	 0.33	
>.98
E	2
B254PHRVHB-E
——	
0.90	-20/-29	
	<10%	X	
—	
—	
PS	 -E	 41
			 480		
108	 0.24				 >.95
	
	120	
	 112	 0.93	
>.99
	
E	2
B254PUNV-D 109	 0.39 				
——	 1.00	-20/-29	 >.98		<10%	X	 —	 —	
PS	 -D	29
			
277		
	112	 0.93	
>.99
	
	
	120	
B254PUNVHB-D 109	 0.39 				
——	 1.00	-20/-29	 >.98	<10%	X	 —	 —	
PS	 -D	29
E	2
			
277		
	
	120	
	 107	0.89	
>.99
E	2
B254PUNVPL-A1
——	 0.93	-20/-29	
	<10%	X	 —	 —	
PS	 -A	 A
			 277		
104	 0.38				 >.97
	
	
120	
107	0.89	
>.99
E	2
B254PUNVPLHBA1
——	 0.93	-20/-29	
	<10%	X	 —	 —	
PS	 -A	 A
			
277 		
104	 0.38				
>.97
	
	120	
	174	 1.45	
>.98
E	3
B454PUNV-E 171	 0.62				
——	 0.93	-20/-29	 >.95	<10%	X	 —	 —	
PS	 -E	 44
			
277		
	
	120	
	174	 1.45	
>.98
E	3
B454PUNVHB-E 171	 0.62				
——	 0.93	-20/-29	 >.95	<10%	X	 —	 —	
PS	 -E	 44
			
277		
	
	120	
	
148	1.25	
>.99
E	3
B454PUNVPL-E1
——	 0.93	-20/-29	
	<10%	X	 —	 —	
PS	 -E	 B
			 277		
146	 0.54			
>.97	
	
	148	1.25	
>.99
	
	120	
B454PUNVPLHBE1
——	 0.93	-20/-29	
	<10%	X	 —	 —	
PS	 -E	 B
E	3
			 277		
146	 0.54				 >.97
	
	120	
	229	 1.91	
E	4
B454PUNV-E 223	 0.80 ——	 0.90	-20/-29	 >.98	 <10%	 X	 —	
—	
PS	 -E	 44
			
277		
	
	120	
	229	 1.91	
E	4
B454PUNVHB-E 223	 0.80 ——	 0.90	-20/-29	 >.98	 <10%	 X	 —	
—	
PS	 -E	 44
			
277		
	
	120	
	 191	1.61	
>.99
E	4
B454PUNVPL-E1
——	 0.93	-20/-29	
	<10%	X	 —	 —	
PS	 -E	 B
			 277		
187	 0.69			
>.98	
	
	
	120	
	
1
91	1.61	
>.99
E	4
B454PUNVPLHBE1
——	 0.93	-20/-29	
	<10%	X	 —	 —	
PS	 -E	 B
			 277		
187	 0.69				 >.98
1 Consult factory for availability

REFERENCE DRAWING FOR -B
L	

W	

H	

M	

X

Compact Fluorescent

	Dwg.	

	-B	 9.50”	 1.50”	 1.00”	 8.89”	 0.88”

REFERENCE DRAWING FOR C3
C

REFERENCE DRAWING FOR C4

F

A

G

B
D
E

	Dwg.	

A	

B	

C	

D	

E	

F	

G

	C3	 2.31”	1.00”	4.25”	4.61”	4.94”	0.98”	1.00”
	Dwg.	

A	

B	

C	

D	

E	

F	

Leadless-Poke-in wire connection

G

	C4	 2.98”	1.00”	4.25”	4.61”	4.94”	1.56”	1.00”

REFERENCE DRAWING FOR C6

Leadless-Poke-in wire connection

REFERENCE DRAWING FOR -D, -E, ESK
	Dwg.	

L	

W	

C

A

B

H	

M	

F

111/16"

5/16"

X	

	-D	 16.88”	1.18”	 1.00”	 16.20”	 --	 -E	 16.88”	1.74”	 1.18”	 16.28”	 ---A	 9.5”	 1.70”	 1.18”	 8.89”	 1.69”
	ESK	 16.65”	 1.24”	 1.00”	 16.30”	 --Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances

E
D

PAGE 3-19

	Dwg.	

A	

B	

C	

D	

E	

F

	C6	 2.40”	 1.55”	 8.31”	 8.89”	 9.50”	 1.19”
Lead Lengths: Side
	
• Black/White–11˝
	
• Red/Blue–16˝
	
• Yellow–16˝

MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS

LONG TWIN
T5 LAMPS

WIRING DIAGRAMS
Line

Black
White

BALLAST

Blue
Blue
Red

Black
White
Green

Red

BALLAST

Yellow
Blue

DIAGRAM 12
Parallel lamp operation
;

DIAGRAM 23
Series lamp operation

Cap unused blue lead; insulate to 600 volts.

Line

Black
White

BALLAST

DIAGRAM 42
For one lamp application, individually cap
yellow and yellow/black leads, insulate to 600V

Blue
Blue
Blue
Red

DIAGRAM 27
Series lamp operation

DIAGRAM 43

DIAGRAM 14
Parallel lamp operation
;

Cap unused blue lead; insulate to 600 volts.

Black
White
Green

BALLAST

Red

Blue

Black

Red

White
Green

DIAGRAM 28

Red
Yellow

BALLAST Yellow
Blue

Compact Fluorescent

Blue

DIAGRAM 20
Series lamp operation

Black

Red

White

Red

Green

BALLAST

DIAGRAM 44

DIAGRAM 29

For one lamp operation,
cap blue leads individually,
insulate to 600V.

Blue
Blue

Line

DIAGRAM A

DIAGRAM 41

Mount lamp within 1" of grounded metal reflector.

DIAGRAM 21
For three lamp operation, cap
Blue/White leads individually,
insulate to 600V.

DIAGRAM B

DIAGRAM 50

FOR MORE INFORMATION CALL

PAGE 3-20

1-800-BALLAST
(225-5278)

Notes

Compact Fluorescent

FOR MORE INFORMATION CALL

PAGE 3-21

1-800-BALLAST
(225-5278)

Ballasts For High Intensity
Discharge Lamps
Universal Means Higher
Expectations In High
Intensity Discharge
Universal Lighting Technologies (“Universal”) offers a
wide array of ballasts for High Intensity Discharge (HID)
lamps. Applications include Metal Halide (MH), Pulse
Start Metal Halide (PSMH), and High Pressure Sodium
(HPS) lamps ranging from 35 to 1500 watts.
We’re the technology leader in every category of
HID ballasts. Our Universal Precise™ line is the latest
innovation in magnetic core & coil technology in years.

HID

Universal offers a complete line of HID ballasts for applications ranging from
35 - 1500 watts.

Universal Lighting Technologies is a member of the Panasonic Group

Product Overview
Core & Coil
Core & coil ballasts are used in over 90% of all HID fixtures. Universal’s core & coil models are available for
all HID lamp types, including single-, dual-, tri-, quad- and multi-volt designs. For added
versatility and reduced inventory costs, Universal has also introduced the industry’s first Multi-5™
ballast (120, 208, 240, 277, or 480 volt), featuring a 480-volt tap on a conventional quad-tap ballast.
Our core & coil models are ideal for a wide variety of lighting applications, including factories,
warehouses, gymnasiums and retail stores. All these ballasts feature precision-wound coils, ensuring even
heat dissipation and the highest electrical integrity.
Universal’s Universal Precise™ is the next generation in core & coil technology, featuring a smaller, lightweight design and improved temperature performance. Universal Precise™ fits virtually all
applications, and has no exposed live metal parts. There are no plastic extrusions, which prevents
breakage during shipping. Color-coded leads make installation easy.
50 Hertz
Universal offers 50 Hz core & coil ballasts to meet the rapid growth in demand in international
markets. Our ballasts are available for 220, 230, and 240 volt electrical systems.

HID

F-Can
These ballasts are used primarily for indoor downlighting applications where quiet operation is essential.
All the components of these ballasts are enclosed in a fluorescent-style ballast can and are thermally
protected.

F-Can Ballasts

Core and Coil Ballasts

PAGE 4-2

HID Ballast Kits

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Product Overview
For maximum safety and reliability, all Universal capacitors come with built-in bleed resistors (patented
by Universal) and approved by CSA (CSA file #LR51331, metal cases only). Environmental safety is
assured by use of biodegradable, nontoxic (no PCBs) dielectric fluid (soybean oil), patented by Universal
for use in capacitors. Dry-film capacitors do not include protective devices. Since they can fail in a hazardous manner, it is the responsibility of the purchaser to take appropriate precautions.
Capacitors
Universal has a comprehensive line of capacitors in metal cases (up to 525V ratings) and plastic cases
(up to 400V ratings). All Universal capacitors are designed for 60,000 hours of continuous life. They’re
exceptionally reliable because we put them through accelerated life testing at 125% rated voltage and
rated temperature +10°C.
Universal capacitors are normally packaged with ballasts. They may also be ordered separately, bulk
packaged, or individually boxed with the suffix “BH” (metal cases only). Capacitor weights vary from
1/4 lb. to 1 lb. each.
Dry Capacitors
Type “P” plastic case capacitors described in this section are dry and do NOT contain safety
interrupters (or oil). Plastic cases are UL rated “94V-O” (for use up to 100°C maximum). Type “P”
capacitors are supplied with stranded copper wire leads 8 inches long (18 awg, with 150°C rated insulation). Capacitor rolls are sealed inside plastic cases using epoxy. Design and testing of Universal
capacitors follow specifications in Electronic Industries Association (EIA) Standard 456-A, titled
“Metalized Film Dielectric Capacitors for Alternating Current Application.”
“P” capacitors are designed and rated for continuous duty AC voltages below 400VAC @ 50 or 60 Hz.
Capacitors used with HID ballasts at voltages above 400VAC should contain interrupters (available from
Universal in oval “MF” and round “RMF” oil-filled metal cases).

Plastic Dry Type Capacitors

Metal and Oil Filled Capacitors

HID

Protective Device (Only in metal cases)
Protective device to prevent case rupture

Normal Cover Position
Normal Cover Position

1/2"
1/2"

Barrier

Normal Position of Protective Device

Barrier

Barrier

Position of Protective Device
After Activation

Capacitor Protective
CapacitorDevices
Protective Devices

PAGE 4-3

Barrier

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Oil-Filled Capacitors
VACr	

	 5.0	

300	

	 6.0	

Part #	

Case	

Ht (“)

	 µF	

VACr	

Part #	

Case	

Ht (“)

005-1466-BH	 1.25 oval	

2.2

	22.5	

300	

005-1419-BH	 1.50 oval	

3.5

300	

005-1561-BH	 1.25 oval	

2.2

	24.0	

360	

005-3160-BH	 1.75 oval	

3.1

	 7.0	

300	

005-1410-BH	 1.25 oval	

2.2

	24.0	

400	

005-2664-BH	 1.75 oval	

3.1

	 8.0	

330	

005-1411-BH	 1.25 oval	

2.2

24.0	

480	

005-2779-BH	 1.75 oval	

3.9

	10.0	

330	

005-1413-BH	 1.25 oval	

2.7

	24.5	

300	

005-3278-BH	 1.75 oval	

2.7

	10.0	

400	

005-1184-BH	 1.50 oval 	

2.7

	26.0	

330	

005-2669-BH	 1.75 oval	

3.1

	10.0	

400	

005-2167-BH	

1.75 dia	

2.9

	26.0	

525	

005-2776-BH	 1.75 oval	

4.3	

	12.0	

300	

005-1467-BH	 1.25 oval	

3.1

	28.0	

240	

005-1886-BH	

1.75 dia	

2.3

	12.0	

400	

005-2799-BH	 1.50 oval	

2.7

	28.0	

300	

005-1468-BH	 1.75 oval	

3.1

	12.0	

440	

005-1464-BH	 1.50 oval	

3.1

	28.0	

425	

005-1799-BH	 1.75 oval	

3.9

	13.0	

300	

005-1414-BH	 1.25 oval	

3.1

	30.0	

440	

005-1475-BH	 1.75 oval	

3.9

	14.0	

240	

005-1884-BH	

1.75 dia	

2.3

	32.0	

300	

005-2351-BH	 1.75 oval	

3.1	

	14.0	

300	

005-1415-BH	 1.50 oval	

2.7

	32.0	

525	

005-1474-BH	 2.00 oval	

3.9

	15.0	

400	

005-1185-BH	 1.75 oval	

2.7

	33.0	

300	

005-1470-BH	 1.75 oval	

3.1

	16.0	

300	

005-1498-BH	 1.50 oval	

2.7

	35.0	

330	

005-1421-BH	 1.75 oval	

3.1

	17.5	

300	

005-1417-BH	 1.50 oval	

3.1

	36.0	

525	

005-2793-BH	 2.00 oval	

4.3

	18.0	

440	

005-1401-BH	 1.75 oval	

3.1

	40.0	

240	

005-1887-BH	

1.75 dia	

2.7

	18.5	

330	

005-1796-BH	 1.50 oval	

3.1

	40.0	

300	

005-1768-BH	 1.75 oval	

3.9

	20.0	

240	

005-1885-BH	

1.75 dia	

2.3

	48.0	

330	

005-1422-BH	 1.75 oval	

3.9

	20.0	

330	

005-1418-BH	 1.50 oval	

3.1

	52.0	

240	

005-1888-BH	

2.00 dia	

2.9

	20.5	

400	

005-3262-BH	 1.75 oval 	

3.1

	55.0	

240	

005-1594-BH	 1.75 oval	

3.5

	21.0	

525	

005-1495-BH	 1.75 oval	

3.9

	55.0	

300	

005-2117-BH	 1.75 oval	

3.9

HID

	 µF	

PAGE 4-4

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Dry Capacitors
--			100°C Rated		
µF	 V		 Part #	
DIA (“) L (“)

--			100°C Rated		
µF	 V		 Part #	
DIA (“) L (“)

5.0	 280		 R17058511-BH	 1.26	
5.0	 280		 R17058512-BH	 1.26	
5.0	 330		 R17058539-BH	 1.26	
6.0	 280		 R17058513-BH	 1.26	
6.0	 280		 R17058514-BH	 1.26	
7.0	 280		 R17058515-BH	 1.65	
8.0	 300		 R17058535-BH	 1.65	
8.0	 330		 R17058541-BH	 1.65	
10.0	 280		 R17058517-BH	 1.26	
10.0	 280		 R17058519-BH	 1.65	
10.0	 330		 R17058578-BH	 1.65	
10.0	 400		 R17058555-BH	 1.65	
10.0	400	
	 R17058557-BH	 1.65	
11.0	 400		 R17058558-BH	 1.65	
12.0	 300		 R17058536-BH	 1.65	
12.0	 330		 R17058543-BH	 1.65	
12.0	 400		 R17058580-BH	 1.65	
13.0	 330					
14.0	 170		 R17058500-BH	 1.26	
14.0	 280		 R17058520-BH	 1.65	
14.0	 280		 R17058520-BH	 1.65	
14.0	 400		 R17058560-BH	 1.65	
15.0	 400		 R17058562-BH	 1.65	
15.0	 400		 R17058563-BH	 1.85	
16.0	280	
	 R17058522-BH	 1.65	
16.0	 280		 R17058522-BH	 1.65	
16.0	 330		 R17058547-BH	 1.65	
17.0	 400		 R17058588-BH	 1.65	
17.5	 280		 R17058523-BH	 1.65	

20.0	
20.0	
20.0	
20.0	
20.5	
21.0	
22.0	
22.5	
22.5	
24.0	
24.0	
24.0	
24.5	
26.0	
26.5	
28.0	
28.0	
28.0	
35.0	
35.0	
40.0	
40.0	
48.0	
48.0	
52.0	
52.0	
55.0	
55.0	
55.0	

2.36
2.83
2.24
2.36
2.83
2.83
2.83
2.83
2.83
2.83
2.83
2.83
3.82
2.83
2.83
2.83
3.82
2.83
2.83
2.83
3.82
3.82
3.82
2.83
2.83
2.83
3.82
3.82

170		 R17058501-BH	 1.65	
280		 R17058526-BH	 1.65	
330					
400		 R17058564-BH	 1.85	
400		 R17058565-BH	 1.85	
400		 R17058567-BH	 1.85	
400		 R17058569-BH	 1.85	
280		 R17058527-BH	 1.65	
280		 R17058528-BH	 1.65	
280		 R17058529-BH	 1.65	
400		 R17058571-BH	 1.85	
400				
330		 R17058552-BH	 1.65	
300		 R17058537-BH	 1.65	
400		 R17058574-BH	 1.85	
170		 R17058502-BH	 1.65	
280		 R17058530-BH	 1.65	
330		 R17058553-BH
1.85	
280		 R17058531-BH	 1.65	
280		 R17058532-BH	 1.85	
240		 R17058505-BH	 1.65	
240		 R17058506-BH	 1.65	
280		 R17058533-BH	 1.85	
330		 R17058554-BH	 2.05	
170		 R17058503-BH	 1.85	
280		 R17058534-BH	 1.85	
240		 R17058507-BH	 1.85	
240		 R17058509-BH	 1.85	
300		 R17058538-BH	 1.85	

2.83
3.82
3.82
3.82
3.82
3.82
3.15
3.82
3.82
3.82
4.76
4.76
4.76
2.83
4.76
3.82
3.82
4.76
3.82
4.76
4.76
4.76
3.82
4.76
3.82
4.76
4.76

HID

PAGE 4-5

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

on center

5.75"

1 Slot
laces

7.75"
2.75"

Bracket Reference Chart

1.75"

on center

2.65"

Bracket B4

0.50"
TYP.

CORE & COIL
WELDED
BRACKETS

CORE & COIL
ADJUSTABLE
MOUNTING
Bracket B4B R A C K E T S
6.10"

on center

0.55"

6.75"

0.50"

5.75"

on center

.640"

7.75"

7.75"

BracketAll welded
B3brackets are .093” thick.

0.75"0.25"
Ref. Drawing ADJ1

.250 Slot
2 Places

1.25" 1.00"

0.75"0.25"
0.75"0.25"

3.35"

0.75"0.25"

1.25" 1.00"

0.30"

3.35"

4.00"

0.30"

3.35"

5.25"

0.30"

Bracket B2
Bracket B1-A

.281 Slot
6 Req.

.281 Slot
2 Places
0.75"0.25"
.250 Slot
2 Places
1.25"
2.65"

6.75"
3.35"

Bracket B1
on center

4.00"
7.75"

0.55"

4.60"

.640"0.50"

7.75"

Ref. Drawing B4

BracketB1-A
B4
Bracket
Bracket B3

2.75"

0.30"

0.70"
2.65" 6.10"
4.60" on
center

5.25"

0.25" Dia.
3 Holes

6.10"

Bracket
B2 B4
Bracket

0.50"
TYP.

7.75"

Bracket B3

0.25" Dia.
20.55"
Holes

6.75"

1.50"

Bracket
B1-B
Bracket
B4

OR

.640"

For use with:

0.25" Dia.

3 Holes
• 50 to 175 watt Mercury, High Pressure
Sodium and
Metal Halide and some 250 watt Metal Halide

Bracket B4
.640"

7.75"

1.50"
0.90"

6.10"

0.55"

0.93"
0.70"

0.70"

.29"

7.75"

7.75"
4.60"
6.75"
on center
5.25"

2.65"

0.58"

on center

0.50"

45º

0.70"
6.10"

on center

3 Holes

0.29"

on center

0.70"

0.25" Dia.
1.30"

1.75"

0.93"

R. TYP.

0.50"

0.09"

.640"

0.50"

R. TYP.

0.55"

0.43"

7.75"

.281 Slot
6 Req.

on center

1.50"

Bracket
B2 B4
Bracket

5.50"

6.75"

on center

1.81"

2.65"

on center

7.75"

on center

1.75"

.281 Slot
6 Req.

0.70"
5.25" 6.75"

0.50"

R. TYP.

Ref. Drawing MB1

1.25"

1.00"
1.75"
2.75"0.25"

R. TYP.

.281 Slot
6 Req.

on center

TYP.

.281 Slot
6 Req.

1.75"

on center

TYP.

Bracket B1-A
Bracket B3

4.00"
7.75"
7.75"

Ref. Drawing B1-B

1.50"

7.75"

TYP.

0.30"

1.25" 1.00"
2.75"

0.50"

3.35"

0.50"

6.10"

Bracket B2

2 Places

0.70"

on center

on center

.281 Slot
2 Places

Ref. Drawing ADJ2 .250 Slot

OR

1.25" 1.00"
0.70"
2.75" 1.75"

0.30"
R. TYP.

4.00"

0.50"

Bracket B1-A
5.25"

Ref. Drawing B3

0.75"0.25"

0.50"
TYP.
1.25"

4.60"

0.30"

4.00"

Bracket B1-A
Bracket B1

.281 Slot
2.75" 1.75" 2 Places
on center
0.75"0.25"
3.35"

3.35"

Bracket B1

4.00"

Ref. Drawing B1-A

0.30"

OR

4.00"

4.60"

0.30"

4.00"3.35"

HID

0.25
3H

Routinely supplied with replacement kits.

Ref. Drawing B2
0.75"0.25" .250 Slot
2 Places

0.30"

0.70"

0.70"

R. TYP.

Bracket B3

Ref. Drawing B1

7.75"

.281 Slot
6 Req.

OR

0.25" Dia.
3 Holes

Ref. Drawing MB2
OR

7.25"

.090"

1.880" .460"
2.685"

1.300"

1.750"

45ϒ

.835"
.290"
.930"

.580"
.290"

OR

.735"
1/4"

Dia.
2 Holes

For use with:
• 250 to 1500 watt Metal Halide
• 250 to 1000 watt High Pressure Sodium and
Mercury Vapor

OR

PAGE 4-6

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Application And Operating Information
Underwriters’ Laboratories, Inc. Acceptance
All F-Can and Weatherproof ballasts listed in this
catalog are Underwriters’ Laboratories, Inc. white card
listed, except those for 347 volt operation. All Core &
Coil and Potted Core & Coil ballasts listed in this catalog are Underwriters’ Laboratories, Inc.
yellow card listed (component recognized).
Ballast Replacement
Ballast replacement presents the possibility of
exposure to potentially hazardous voltages and should
be performed only by qualified personnel. All installation, inspection and maintenance should be performed
only with the entire circuit power to fixture or equipment turned off. Installation shall be in accordance
with National Electric Code.
Heat
A ballast, like any other electrical device, generates
heat during normal operation. Planning for maximum
heat dissipation with proper fixture design, installation planning and ballast selection will minimize the
possibility of a heat-related problem arising. Excessive
temperature will have an adverse effect on ballast life.
	
	
	

Normal temperature limits:
F-Can Ballasts
Maximum case temperature: 90°C

	
	
	
	
	

Potted Core & Coil Ballasts and
Core & Coil Ballasts
Insulation: Class 180°C
Maximum coil temperature: 165°C
(measured by change of resistance method)

temperature. The ballast will continue to cycle until
the cause of overheating is eliminated. If the ballast is
defective, it must be replaced. If the cause is external,
the ballast will resume normal operation after
abnormal conditions are eliminated.
To attain normal ballast life, the maximum coil
temperature of the ballast should not exceed the
rating of the insulation system. A temperature increase
of 10° C results in a 50% reduction of ballast life.
Low Ambient Temperature (cold)
As temperatures drop, less and less vaporized gas is
available within the arc tube of a high intensity
discharge lamp, thereby causing an increase in the open
circuit voltage required to initiate an arc in the lamp,
until a point is reached where the lamp cannot be started. The minimum temperature at which any ballast listed
in this catalog will provide reliable starting is
listed with the electrical characteristics.
Ballasts should be protected from weather, moisture, or
other abnormal atmospheric conditions, unless specifically designed for use under adverse conditions.
Fusing
The purpose of fusing an HID ballast is to remove the ballast
from the power line in the event of a ballast system failure.
A fuse does not protect the ballast from failing.
Because the temperature in the ballast compartment is
high, typically 90OC, fuse ratings are specified at 25OC, and
that this rating declines as the temperature increases, HID
fuse recommendations are made between 2 and 3 times
the maximum current the ballast will draw during all normal
conditions.

All F-Can ballasts listed in this catalog are equipped
with built-in automatic resetting internal thermal
protection as a standard feature.

Fast-blow fuses should not be used due to the possibility of
high inrush currents. These currents are due to the
fact that the power can be applied ant any point in the AC
voltage waveform. Standard and slow-blow are acceptable.

Whenever a ballast with thermal protection is used, it
is imperative that the fixture/ballast/lamp combination
be heat tested under actual or simulated installation
conditions to assure that the ballast will not cycle.
The resetting thermal protector functions as a
thermostat which will open and temporarily
deactivate the ballast when it exceeds the permissible

When using the 120V tap for auxiliary lighting, a slow-blow
fuse should be used to protect the ballast from damage
from a fault in the auxiliary lighting circuit.
HID

REMOTE MOUNTING DISTANCE

Maximum Length in Feet for Remote Mounting of HID Ballasts to Lamp
ANSI	

Lamp Type	

Watts	

12 GA	

14 GA	

16 GA	

18 GA

M57	
Metal Halide	
175	
272	
171	
107	
67
M58	
Metal Halide	
250	
194	
122	
77	
48
M59	
Metal Halide	
400	132	83	52	33
M47	
Metal Halide	
1000	
196	
123	
77	
48
M48	
Metal Halide	
1500	146	92	58	36
For proper installation, insure that remote ballasts are properly vented and mounted to a heat-dissipating surface.

PAGE 4-7

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Application And Operating Information
Sound
High intensity discharge lamp ballasts, like all electromagnetic devices, produce noise, or “hum.” It is the
degree of noise which determines the existence of
a problem. Ballast noise will only be noticeable when
it exceeds the ambient sound level of the installation.
It is obvious that a ballast designed primarily for
outdoor or factory use would not be suitable in an
office environment.
The vast improvements in all high intensity discharge
lamps and ballasts, and their excellent energy
efficiency, have made them viable options for many
indoor applications. The ballasts being considered
should be carefully analyzed to insure that there will
not be an objectionable level of ballast noise.
All F-Can ballasts listed in this catalog are “Sound
Rated” to aid in the selection of a ballast which is
proper for the environment in which it will operate.
Potted Core & Coil ballasts are also designed to
operate at reduced sound levels, generally several
decibels lower than a standard Core & Coil ballast.
Core & Coil ballasts are not sound rated.

HID

In situations where light output necessitates using a
ballast with a sound rating or noise level not normally
acceptable, the ballast should be remotely mounted.
Note, however, that not all ballasts listed in this
catalog are designed or recommended for remote
mounting.
Polarity
Polarity refers to the proper connection of ballast
lead wires to line wires. To aid you in making a
correct installation, Universal ballast leads are
color-coded for easy identification. The white or
yellow ballast lead is to be connected to the neutral
or common. Choose the appropriate ballast voltage
lead to connect to the line.
Grounding
Ballasts and capacitors or starters in metallic casings
must always be grounded. Ballasts and components
may be grounded to the fixture or otherwise
connected to ground. It would be hazardous to make
contact with an ungrounded fixture, ballast or other
electrical component while in operation.

Operating Line Voltage Limits
To receive the full benefits of rated lamp output and
to prolong ballast life, it is essential that the voltage
supplied to an installation be maintained within the
prescribed limits.
In general, the line voltage supplied to a lag type
ballast (reactor or high reactance autotransformer)
should be maintained within 5% of the voltage for
which the ballast is rated. The line voltage to lead type
ballasts (constant wattage autotransformer or constant
wattage isolated) should be maintained within 10%.
Subjecting a ballast to excessive voltage for an
extended period of time results in the deterioration
of the coil insulation. This insulation breakdown will
cause early ballast failure.
Low voltage has no damaging effect on the ballast.
It could, however, have an adverse effect on lamp
performance and starting dependability.
Maintenance
Selecting and installing an adequate and efficient
lighting system means nothing if it is not properly
maintained. Maintenance must always be considered
as part of the life cycle cost of any high intensity
discharge lighting installation in order to assure the
continued performance of the system as originally
specified.
First and foremost in importance is proper lamp
maintenance. High intensity discharge lamps do
not “burn out” like an incandescent bulb, but rather,
undergo changes within the arc tube which prevent
the lamp from starting properly, warming up and
producing full light output. The beginning of
difficulties such as these generally indicates the
end of a lamp’s useful life. Also, a dead lamp left
in a fixture can be very damaging to the ignitor in
systems which utilize them. To overcome this problem,
Universal offers automatic shutoff ignitors, which are
described in the ignitor section of this catalog.

PAGE 4-8

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Application And Operating Information
In difficult locations, group replacement of all the
lamps, working or not, is often more economical
and convenient than spot replacement. The same,
of course, applies to ballasts which might be
approaching the end of their life. Only you can decide
what is right for your lighting system, but what is
important is that you have a maintenance program.
Periodic cleaning of the fixtures’ lenses and reflectors
is also important in maintaining proper light output.
For indoor systems, maintenance of reflective
surfaces, such as walls and ceilings, will also help
assure proper levels of illumination.

STANDBY LIGHTING AND PACKAGING
Standby Lighting
To provide light during a high intensity discharge
lamp’s warmup period, or the cool-down period
following a power interruption which has
extinguished it, incandescent standby lighting can
be incorporated. This is accomplished by use of a
standby lighting device, or remote, that switches off
an incandescent lamp incorporated into the fixture
once an arc has been established, or reestablished,
in the HID lamp. Generally, standby lighting devices
operate on 120 volts, so a tap must be provided on
ballasts designed to operate at higher line voltages.
The 120 volt terminal or lead on all Universal dual-,
tri-, quad- and multi-volt ballasts can be used as a
tap for standby lighting when the ballast is utilized
for any of the higher voltages. Many single voltage
ballasts are available with a 120 volt tap and are
listed throughout the Core & Coil data section. Other
single voltage ballasts may be available in this
version. Consult our Customer Service Department
for availability and price information.

Packaging
Standard Pack
Universal’s high intensity discharge lamp ballasts
are routinely packed in easy-to-handle cartons
containing from 1 to 20 units per carton, depending
on the size and weight of the ballasts. Consult
Customer Service for the number of “units per carton”
for shipment with attached mounting brackets,
capacitors (for high power factor units), and ignitors
(if required). Other ordering criteria may cause
packaging to vary.
Tray Pack
For the convenience of large quantity users who
request it, Universal ballasts may be packed in trays.
The number of units depends upon the size and weight
of each ballast. These trays are large corrugated
cartons with lids and sides that come off easily.
This type of packaging affords Universal customers a
savings of time and money on their own production
costs. There are fewer cartons to open, break up and
dispose of on the assembly line; warehouse handling
is reduced and inventory control is easier. There is no
additional charge for tray packing.
Individual Cartons
All Distributor Replacement Kits, Weatherproof, Potted
Core & Coil and other larger ballasts are packaged in
individual cartons.
Individual cartons serve a threefold purpose: as a
display carton, a stock package, and a shipping
container for the retail market. Individual cartons may
be packed in master cartons, depending on weight
and size.
Individual carton packaging may be available for other
ballasts. Contact our Customer Service Department for
availability and cost.

PAGE 4-9

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID

Any connection to the 120 volt tap must be
accomplished by means of a slow-blow fuse. This
fuse will protect the ballast from abnormal conditions
in the standby lamp circuit or its control device.
The fuse should be located in the coolest place in
the fixture (below 80°C). The recommended fuse
amperage and maximum auxiliary lamp wattage
are listed in this catalog for each ballast suitable

for standby lighting applications. Be sure to follow
the wiring instructions of the standby lighting device
manufacturer. All applicable requirements of the
National Electrical Code must be met.

Nomenclature
UNIVERSAL PRECISE™
ABBREVIATIONS

UL Bench Top Rise Temperature Code

CWA	

Constant Wattage Autotransformer

CWI	

Constant Wattage Isolated

ISO	

Regulated Lag

R-HPF	

Reactor—High Power Factor

R-NPF	

Reactor—Normal Power Factor

To facilitate UL inspection, the UL Bench Top Rise
Temperature Code is shown on the Universal Core &
Coil Ballast label as 1029X. 1029 is the UL Standard
for HID Ballasts, and the X is the
temperature code. If a fixture is UL listed for 1029D,
then automatically all ballasts with an A, B, C or D
temperature classification are acceptable for use
within that same fixture.

HX-HPF	 Lag Type — High Reactance 		
Autotransformer—High Power Factor
	

UL Bench Top Rise Letter Code
Temperature Range for
Class H (180° C) Ballasts

HX-NPF	 Lag Type — High Reactance
	
Autotransformer—Normal Power Factor

B 75°C < 80°C	 C 80°C < 85°C	
A<75°C		
D 85°C < 90°C	 E 90°C < 95°C	 F 95°C < 100°C

Field

1

2

3

4

5

6

7

8

9

1 1
C 5

1
M

3
0

1
C

Number of Digits

HID

0

0

Container Type
(C/T/I/K)

Wattage

	Field	

1
A

Pack Code
(000 TO 999)

Lamp Type
(M/P/S/H)

3
M L T

Socket Type & Other
Oddities (M/D/X/L)
Frame Size
(E/3/4/5/X)
Style
(C/F/W/E/I/P)
Circuit Type
(R/A/I/O/L/M)

2 to 4
2 0 0 0

Primary
Voltage
(MLT/ML5/TRI/
48T/120/277/
230)

1
M

Description

	 1	

(M) Metal Halide, (P) Pulse Start Metal Halide, (S) High Pressure Sodium

	 2	

35 to 1500 Watts (Varies from two to four digits)

	 3	

(MLT) Quad, (ML5) Multi-5, (TRI) TriVolt, (48T) 480/120, (120) 120, (277) 277, (230) 230V/50Hz

	 4	

(R) Reactor, (A) CWA, (I) CWI, (O) IsoReg, (L) High Reactance/Lag, (M) MagLag

	 5	

(C), C&C, (F) F-Can, (W) Weatherproof, (E) Encased/Potted C&C (I) Indoor Encased

	 6	

(E) E&I, (3) 3x4, (4) 4-3/4, (5) 5-3/4, (X) Non Core and Coil

	 7	

(M) Mogul or Medium, (D) Double Ended, (L) Low Loss

	 8	

Pack Code (000 to 999, per pack code listing)

	 9	

(C) Carton, (T) Tray, (I) Individual, (K) Kit

PAGE 4-10

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Specifications
TYPICAL SPECIFICATIONS
FOR HID BALLASTS
1. 	 Ballasts shall be designed in accordance with all applicable ANSI specifications including ANSI C82.4.
2 .	 The Core & Coil ballast shall be designed with class “H” (180°C) or higher insulation system and vacuum
	
impregnated with a 100% solid based resin.
3 . All coils shall be precision wound.
4 . Core & Coil ballasts shall be designed to operate at least 180 cycles of 12 hours on and 12 hours off, with
	
the lamp circuit in an open or short-circuited condition and without undue reduction in ballast life.
5. 	 Core & Coil ballast and starter combinations shall be designed to provide a reliable lamp starting down to
	
-40°C for High Pressure Sodium and Pulse Start Metal Halide and -30°C for Metal Halide and Mercury at
minimum rated line voltage.
6.	 Manufacturer shall provide written warranty against defects in workmanship, including replacement, for two
	
years from date of manufacture.
	

CAPACITORS

	

1. 	 All capacitors will be provided with a self-contained internal bleeder resistor.

	
2. 	 All oil-filled capacitors will be housed in corrosion-resistant steel cans and contain .25” quick disconnect
		terminals.
3. 	 All capacitors will be supplied by ballast manufacturer.

	

IGNITORS

	

1. 	 All ignitors will be epoxy-filled with either a plastic or aluminum external housing.

	

2. 	 The ignitor shall be so designed to provide six months of lamp open circuit operation without failure.

	

KITS

	

1. 	 All HID kits shall be precision wound to insure proper insulation.

	

2. 	 All HID kits shall be pre-wired.

	

3. 	 All HID kits shall be built with color-coded leads.

HID

	

	
4. 	 All HID kits are to be UL and CSA recognized following the guidelines found in UL 1029 and
		 CAN/CSA-22.2 No. 74-92 (part 2 and 3).
	

5.	 Universal Model __________________________ (or approved equal).

PAGE 4-11

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Distributor Replacement Kits
Universal’s HID distributor replacement kits contain the appropriate core & coil, a properly rated capacitor, and all
other components required for ballast replacement. Our kits are the quickest and easiest to install of any on the
market, thanks to unique design features like:
	
	
	
	
	

•	
•	
•	
•	
•	

Prewired capacitor and ignitor (if required) to save installation time and reduce wiring errors.
Color-coded leads to reduce risk of incorrect wiring inside the fixture.
Features that exceed UL standards, including capacitors that offer trip fault protection.
Simple installation instructions and troubleshooting tips.
UPS shippable box.

Our kit offerings include many quad voltage (120, 208, 240, or 277 volt) and 480 volt core & coil ballasts, as well as
the new Multi-5 five-voltage ballast. 480 volt ballasts are equipped with a 120 volt tap to accommodate stand by
lighting.
Also available for Metal Halide and High Pressure Sodium applications, Universal Lighting’s Multi-5TM Ballast-Lamp
Replacement Kit. This easy to carry convenient all-in-one kit ensures ballast lamp compatibility.
Distributor replacement kit cartons are packaged in master cartons in quantities from 1 to 6 units. Master carton
quantities can be found on Universal’s list and distributor price sheets.

Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits
Wattage	

Voltage	

Frame Size	

Old Part Number	

		

175	

120/208/240/277	

3 x 4	

1130-91R-500K	

M175MLTAC3M500K

		

Multi-5™ Uni-Pak™	
175	

3 x 4	

New	

M175ML5AC3M555K

	

LampType	

		

		
		

	Metal	
	

Halide	
	

		

		
		
		
		

		
		
HID

175	
250	

		
	

175	

250	

Multi-5	

480-120	

120/208/240/277	
Multi-5	

250	Multi-5™ Uni-Pak™	
250	
250	
250	

480-120	

120/208/240/277	
Multi-5	

3 x 4	

3 x 4	

1130-31-500K	

3 x 4	

New	

3 x 4	

400	
400	

3 x 4	

4.25 x 4.75	
4.25 x 4.75	

1130-826S-500K	

480-120	

4.25 x 4.75	

1130-33R-500K	

Multi-5	

4.25 x 5.75	

New	

Multi-5™ Uni-Pak™	 4.25 x 5.75	
1000	

		
		

1000	
1500	
1500	

New	

4.25 x 4.75	

		
		

New	

Multi-5	

4.25 x 4.75	

1000	
1000	

1130-32-500K	

1130-92R-500K	

4.25 x 4.75	

		
		

New	

480-120	

120/208/240/277	

Multi-5™ Uni-Pak™	 4.25 x 4.75	
400	
400	

1130-92-500K	

3 x 4	

Multi-5™ Uni-Pak™	 4.25 x 4.75	
250	
250	

New	

120/208/240/277	

4.25 x 5.75	

480-120	

4.25 x 5.75	

480-120	

4.25 x 5.75	

120/208/240/277	

4.25 x 5.75	

1130-32R-500K	

1130-93U-500K	
New	

1130-97-500K	
New	

1130-57-500K	

1130-99R-500K	
1130-69R-500K	

PAGE 4-12

New Part Number

M175ML5AC3M500K
M17548TAC3M500K

M250MLTAC3M500K
M250ML5AC3M500K
M250ML5AC3M555K
M25048TAC3M500K

M250MLTAC4M500K
M250ML5AC4M500K
M250ML5AC4M555K
M25048TAC4M500K

M400MLTAC4M500K
M400ML5AC4M500K
M400ML5AC4M555K
M40048TAC4M500K

M1000MLTAC5M500K
M1000ML5AC5M500K
M1000ML5AC5M555K
M100048TAC5M500K

M1500MLTAC5M500K
M150048TAC5M500K

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Distributor Replacement Kits
Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits
	

LampType	

Wattage	

Voltage	

Frame Size	

	

	

35	

120/208/240/277	

3 x 4	

		

70	

120/208/240/277	

3 x 4	

		
		
		

50	
70	

120/208/240/277	

100	

120/208/240/277	

100	

		

100	

		
		
		
		
		
		
		
		
		
		
		
		
		
		
		
		
	

Pulse Start	

150	

120/208/240/277	

150	
175	
175	
175	

		
		
		
		
		
		
		
		
		
		
		
		

120/208/240/277	
120/208/240/277	
Multi-5	

3 x 4	

New	

M100MLTLC3M	

3 x 4	

New	

3 x 4	

New	

3 x 4	

11310-543-500K	

3 x 4	

New	

3 x 4	

New	

3 x 4	

New	

3 x 4	

New	

3 x 4	

New	

3 x 4	

480-120	

4.25 x 5.75	

Multi-5	

3 x 4	

200	
200	
200	

120/208/240/277	
480-120	

480-120	

4.25 x 4.75	

320	
350	
350	
350	
350	
400	
400	
400	

Multi-5	

120/208/240/277	
Multi-5	

480-120	

450	

120/208/240/277	

450	

480-120	

450	
750	
750	
750	

Multi-5	

120/208/240/277	
Multi-5	

480-120	

875	

120/208/240/277	

1000	

Multi-5	

1000	

120/208/240/277	

New	
New	

4.25 x 4.75	

New	

4.25 x 4.75	

480-120	

New	

1130-827-500K	

480-120	
Multi-5	

New	

4.25 x 4.75	

4.25 x 4.75	

120/208/240/277	

New	

4.25 x 4.75	

Multi-5	
Multi-5	

New	

3 x 4	

250	

120/208/240/277	

New	

New	

4.25 x 4.75	

320	

New	

3 x 4	

120/208/240/277	
Multi-5	

New	

3 x 4	

250	
250	

M70MLTLC3M500K

3 x 4	

175	

480-120	

11310-510-500K	
New	

4.25 x 5.75	

175	

M35MLTLC3M500K

4.25 x 4.75	

New	

New	

4.25 x 4.75	

1130-829-500K	

4.25 x 4.75	

New	

4.25 x 4.75	
4.25 x 5.75	
4.25 x 5.75	
4.25 x 5.75	
4.25 x 5.75	
4.25 x 5.75	
4.25 x 5.75	
PAGE 4-13

M100MLTLC3D500K
M10048TLC3M500K

M150MLTLC3M500K

M150MLTAC3M500K
M150MLTLC3D500K
M15048TLC3M500K

P175MLTAC3M500K
P175MLTAC3L500K

P175ML5AC3M500K
P175MLTAC4L500K
P17548TAC3L500K
P17548TAC4L500K

P200MLTAC3L500K

P200ML5AC3M500K
P20048TAC3L500K

P250MLTAC4L500K
P250ML5AC4L500K
P25048TAC4L500K

P320MLTAC4O500K

P32048TAC4L500K

4.25 x 4.75	

4.25 x 4.75	

M100MLTLC3O500K

New	

1130-622-500K	

4.25 x 4.75	

M70MLTLC3D500K

P320ML5AC4M500K

P350ML5AC4M	

4.25 x 4.75	

M7048TLC3M500K

New	

4.25 x 4.75	
4.25 x 4.75	

M50MLTLC3M500K

New	
New	
New	
New	
New	
New	
New	
New	
New	
New	

P320ML5AC4L500K

P350MLTAC4M500K
P350ML5AC4O500K
P350ML5AC4L500K
P35048TAC4L500K

P400MLTAC4L500K
P400ML5AC4L500K
P40048TAC4L500K

P450MLTAC4L500K
P450ML5AC4L500K
P45048TAC4L500K

P750MLTAC5M500K
P750ML5AC5M500K
P75048TAC5M500K

P875MLTAC5M500K

P1000MLTAC5M500K
P1000ML5AC5M500K

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID

		

480-120	

3 x 4	

New Part Number

New	

11310-95-500K	

120/208/240/277	

320	

		

120/208/240/277	

3 x 4	

175	

		
		

480-120	

120/208/240/277	

150	

320	

		

120/208/240/277	

150	

	 Metal Halide	

		

480-120	

70	

		
		

120/208/240/277	

Old Part Number	

Distributor Replacement Kits
Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits
	

LampType	

		
		
		

Wattage	

Voltage	

Frame Size	

50	

120/208/240/277	

3 x 4	

480-120	

70	
70	

120/208/240/277	

Old Part Number	

New Part Number

12310-95-500K	

S50MLTLC3M500K

3 x 4	

12310-148R-500K	

S7048TLC3M500K

3 x 4	

12310-30R-500K	

3 x 4	

12310-160S-500K	

3 x 4	

		

100	

120/208/240/277	

		

150	

120/208/240/277	

200	

120/208/240/277	

4.25 x 4.75	

250	

Multi-5	

4.25 x 4.75	

S250ML5AC4M	

4.25 x 4.75	

1230-32S-500K	

		
		
		
		
		
		
		

	H.P.S.	
		

		
		
		
		
		

		
		
		

100	
150	
200	
250	
250	

480-120	
480-120	
480-120	

120/208/240/277	
480-120	

3 x 4	

12310-153-500K	

3 x 4	

4.25 x 4.75	
4.25 x 4.75	

250	Multi-5™ Uni-Pak™	 4.25 x 4.75	
400	
400	
400	
400	
400	
400	

Multi-5	

4.25 x 4.75	

480-120	

4.25 x 4.75	

120/208/240/277	
Multi-5	

120/208/240/277	
480-120	

4.25 x 4.75	
4.25 x 5.75	
4.25 x 5.75	
4.25 x 5.75	

Multi-5™ Uni-Pak™	 4.25 x 4.75	
400	
600	

120/208/240/277	

4.25 x 5.75	

1000	

Multi-5	

4.25 x 5.75	

1000	

		

Multi-5™ Uni-Pak™	 4.25 x 5.75	
1000	

New	
New	

1230-92S-500K	
New	
New	

1230-93U-500K	
1230-33U-500K	
New	

1230-93S-500K	
1230-33S-500K	
New	

1000	

120/208/240/277	

480-120	

4.25 x 5.75	

4.25 x 5.75	

New	
New	

1230-97S-500K	
New	
New	

1230-57S-500K	

S100MLTLC3M500K
S10048TLC3M500K

S150MLTLC3O500K
S15048TLC3M500K

S200MLTAC4M500K
S20048TAC4M500K

S250ML5AC4O500K

S250MLTAC4M500K
S25048TAC4M500K

S250ML5AC4M555K		
S400ML5AC4M500K

S400MLTAC4M500K
S40048TAC4M500K

S400ML5AC5M500K

S400MLTAC5M500K
S40048TAC5M500K

S400ML5AC4M555K
S400ML5AC5M555K

S600MLTAC5M500K

S1000MLTAC5M500K
S1000ML5AC5M500K
S1000ML5AC5M555K
S100048TAC5M500K

HID

		

S150MLTLC3M	

Multi-5™ Uni-Pak™	 4.25 x 4.75	
400	

		
		

12310-90-500K	

S70MLTLC3M500K

PAGE 4-14

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Distributor Replacement Kits
Canadian Tri-Tap Distributor Replacement Kits
Wattage	

Voltage	

Frame Size	

Old Part Number	

New Part Number

		

175	

120/277/347	

3 x 4	

1130-605-502K	

M175TRIAC30502K

	

250	

120/277/347	

4.25 x 4.75	

1130-593R-502K	

M250TRIAC4M502K

120/277/347	

4.25 x 5.75	

1130-598-502K	

	

LampType	

		
	

Metal	

Halide	

250	

400	

		

1000	

		

35	

		

1500	

		

50	

		

70	

		

100	

	

175	

		

Pulse Start	

	 Metal Halide	
		
	

		

	

		
		
		

150	

200	

250	
320	
350	
400	
750	
70	

		

100	

		

200	

		
	

H.P.S.	

		
		
		

150	

250	
400	
400	

1000	

120/277/347	

120/277/347	
120/277/347	
120/277/347	

120/277/347	

120/277/347	

120/277/347	

120/277/347	

120/277/347	
120/277/347	

3 x 4	

4.25 x 4.75	
4.25 x 5.75	
3 x 4	

3 x 4	

3 x 4	

11310-590-502K	

11310-584-502K	

3 x 4	

New	

3 x 4	

4.25 x 4.75	

120/277/347	

120/277/347	

120/277/347	

New	

11310-604-502K	

3 x 4	

120/277/347	
120/277/347	

1130-599-502K	

3 x 4	

4.25 x 4.75	

120/277/347	

M400TRIAC4M	

New	

120/277/347	
120/277/347	

New	

New	
New	

4.25 x 4.75	

New	
New	

4.25 x 4.75	
4.25 x 5.75	

New	
New	

3 x 4	

12310-579-502K	

3 x 4	

12310-588-502K	

3 x 4	

12310-584-502K	

120/277/347	

4.25 x 4.75	

120/277/347	

4.25 x 4.75	

1230-595U-502K	

4.25 x 5.75	

1230-598S-502K	

120/277/347	
120/277/347	
120/277/347	

4.25 x 4.75	
4.25 x 5.75	

–	

1230-593S-502K	
1230-595S-502K	

M250TRIAC3M502K
M400TRIAC4O502K

M1000TRIAC5M502K
M1500TRIAC5M502K
M35TRILC3M502K

M50TRILC3M502K

M70TRILC3M502K

M100TRILC3M502K

M150TRILC3M502K
P175TRIAC3M502K
P200TRIAC3M502K
P250TRIAC4M502K
P320TRIAC4M502K
P350TRIAC4M502K
P400TRIAC4M502K
P750TRIAC5M502K
S70TRILC3M502K

S100TRILC3M502K

S150TRILC3M502K
S200TRILC4M502K

S250TRIAC4M502K
S400TRIAC4M502K
S400TRIAC5M502K

S1000TRIAC5M502K

HID

PAGE 4-15

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

MH
175-250
WATT

HID CORE & COIL BALLASTS
METAL HALIDE

• 6 0 Hz
• Minimum starting
temperature: -30° C
• Normal and High Power Factor models available

					
Nom				 Dimensions				
Capacitor				
Ignitor
				Max	Open												 Total		 Max	 UL
Input	Catalog*	 Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Oil Filled		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 175 WATT M57, M107 METAL HALIDE LAMP			
120 or	
	2.15	
	5	
M175TRIAC30	 CWA	211 0.95		
305
3	 PC1	 2.45	 3.75	 10	400	 1.65	 3.82	1.56x2.69	 2.7	 6.8	
n/a	
n/a	
C
277 or				
2
347				0.75		 2
120 or	
	1.90	
	5	
A	
208 or M175MLTAC3M	CWA	213 1.10		
3														C
305
1	 PC1	 2.2	
3.6	 10	 400	 1.65	 2.83	 1.56x2.69	 2.7	
6.1 	
n/a	
n/a	
				
240 or				0.95		 3														 B
277				0.85		 2														 C
120 or				1.90		 8														
208 or	
	1.10	 	5		
	
	
	
	
	
	
	
	
	
	
	
	
	
	
240 or	 M175ML5AC3M	 CWA	 208	 0.95	
300	
3	
2	 PC1	 2.3	
3.60	 10	 400	 1.65 	 2.83	 1.56x2.69	 2.7	
6.75	
n/a	
n/a	
B
277 or				0.85		 3														
480				0.50		 2												
		
480	M17548TAC3M	
CWA	 210	 0.51	 315	 2	 4	 PC1	 2.0	 3.3	 10	400	 1.65	 2.83	1.56x2.69	 2.7	 5.6	
n/a	
n/a	
D
(1) 250 WATT M58 METAL HALIDE LAMP - 4” Frame			
120 or				2.8		8														 B
277 or	 M250TRIAC3M	 CWA	 295	 1.20	 320	 3	 3	 PC1	 3.0	 4.35	 15	400	 1.65	 3.82	1.91x2.91	 2.7	 8.0	
n/a	
n/a	
D
347				0.95		 3														 D
120 or				2.60		 8														
208 or	 M250MLTAC3M	CWA	297	1.50	 315	5	1	 PC1	 3.0	 4.25	 15	400	 1.65	 3.82	1.91x2.91	 2.7	 9.0	
n/a	
n/a	D
240 or				1.30		 4														
277				1.10		 3														
120 or				2.50		 8														 A
208 or	
	1.40	 	5		
	A
	
	
	
	
	
	
	
	
	
	
	
	
	
240 or	 M250ML5AC3M	 CWA	 295	 1.25	
285	
4	
2	 PC1	 3.0	
4.5	 15	 400	 1.65	 3.82	 1.91x2.91	 2.7	
9.2	
n/a	
n/a	
B
277 or				1.10		 3														 C
480				0.65		 2												
		 B
347	 M250347AC3M	 CWA	 295	 0.95	 320	 3	 6	 PC1	 3.0	 4.35	 15	400	 1.65	 3.82	1.91x2.91	 2.7	 8.0	
n/a	
n/a	
D
480	 M25048TAC3M	 CWA	 292	 0.64	 320	 2	 4	 PC1	 3.0	 4.3	 15	400	 1.65	 3.82	1.91x2.91	 2.7	 9.0	
n/a	
n/a	
D
Capacitors are available as an option for high power
factor operation.

See page 4-19 for Reference
Drawings and Wiring Diagrams.

HID
CORE & COIL

3

PAGE 4-16

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID CORE & COIL BALLASTS
METAL HALIDE

•
•
•
•

6 0 Hz
Minimum starting temperature: -30° C
High Power Factor models available
Feature CWA design

MH
250-400
WATT

					
Nom				 Dimensions				
Capacitor				
Ignitor
				Max	Open												 Total		 Max	 UL
Input	Catalog*	 Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Oil Filled		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 250 WATT M58 METAL HALIDE LAMP - 4.75” Frame			
120 or				3.05		 8					
277 or	 M250TRIAC4M 	 CWA	 290	 1.25	
305	
3	
3	 PC2	 1.63	
3.63	 15	 400	 1.65	 3.82	 1.91x2.91	 2.7	
9.5	
n/a	
n/a	
B
347				1.05		 3
120 or				2.40		 8		
208 or	
	1.40	
	5	
310
1	PC2	 3.35	 3.53	 15	400	 1.65	 3.82	1.91x2.91	2.7	 8.0	
n/a	
n/a	
B
M250MLTAC4M	 CWA	290
240 or				
1.20		
4
277				1.05		 4
120 or				2.42		 8					
208 or				1.40		 5					
n/a	
n/a	
A
240 or	 M250ML5AC4M	 CWA	 290	 1.20	 300	 4	 2	 PC2	 1.82	 3.62	 15	360	 1.65	 3.82	1.91x2.91	 2.7	 10.8	
277 or				1.00		 3				
480				0.60		 2					
480	
M25048TAC4M	 CWA	 290	 0.61	 300	 2	 4	 PC2	 1.82	 3.62	 15	360	 1.65	 3.82	1.91x2.91	 2.7	 10.8	
n/a	
n/a	
B
(1) 400 WATT M59 METAL HALIDE LAMP			
120	
M400120AC4M	 CWA	 454	 4.00 	 300	
10	 5	 PC2	 2.0	
3.86	 24	 360	 1.85	 3.82	 1.91x2.91	 3.1	
9.3	
n/a	
n/a	
E
120 or				
3.90		
10														C
277 or	 M400TRIAC40	 CWA	 455	 1.70	
295	
5	
3	 PC2	 2.15	
3.90	 24	 360	 1.85	
3.82	1.91x2.91	 3.1	 10.5	
n/a	
n/a	
D
347				
1.35		4														D
120 or				
4.00		
10														
208 or	
2.30
8
M400MLTAC4M	CWA	458	
	300	 	 1	PC2	 2.0	 3.86	 24	360	 1.85	 3.82	1.91x2.91	3.1	 10.0	
n/a	
n/a	
E
240 or				
2.00		5														
277				
1.70		5														
120 or				
4.00		
10														
208 or				
2.30		8														
240 or	 M400ML5AC4M	 CWA	 458	 2.00	 300	 5	 2	PC2	 2.0	 3.86	 24	360	 1.85	 3.82	1.91x2.91	3.1	 11.0	
n/a	
n/a	
E
277 or				
1.70		5														
480				1.00		 50
480	
M40048TAC4M	 CWA	 458	 1.00	 300	 3	 4	 PC2	 2.0	 3.9	 24	360	 1.85	 3.82	1.91x2.91	 3.1	 11.0	
n/a	
n/a	
E

See page 4-19 for Reference
Drawings and Wiring Diagrams.

HID
CORE & COIL

PAGE 4-17

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

MH
1000-1500
WATT

HID CORE & COIL BALLASTS
METAL HALIDEFEATURING MULTI-5™

• 60 HZ.
•M
 inimum Starting Temperature: -30° C
• F eature CWA Design

					
Nom				 Dimensions				
Capacitor				
Ignitor
				Max	Open												 Total		 Max	 UL
Input	Catalog*	 Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Oil Filled		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 1000 WATT M47 METAL HALIDE LAMP			
120	
M1000120AC5M	 CWA	1080	 9.00	 425	 23	 5	PC3	 2.9	 4.75	 24	480	 n/a	 n/a	 1.91x2.91	 3.9	 18.0	
n/a	
n/a 	 D
120 or				
9.00		
20														D
277 or	 M1000TRIAC5M 	 CWA	1080	 3.90	 435	 10	 3	PC3	 3.0	 4.95	 24	480	 n/a	 n/a	 1.91x2.91	 3.9	 19.0	
n/a	
n/a	
D
347				3.20		 8														 E
120 or				
8.95		
20														
208 or	
	5.15	
	15	
425
1	PC3	 2.9	 5.05	 24	480	 n/a	 n/a	 1.91x2.91	3.9	22.0	 n/a	 n/a	 D
M1000MLTAC5M	 CWA	1080
240 or				
4.50		
10														
277				
3.90		
10														
120 or				
9.15		
20														F	
208 or	
	5.25	 	
15														E	
	
	
n/a	
n/a	
E
240 or	 M1000ML5AC5M	 CWA	1080	 4.55	 420	 10	 2	PC3	 2.9	 5.05	 24	480	 n/a	 n/a	 1.91x2.91	 3.9	 22.0	
277 or				
3.95		
10														E
480				2.30		 6														 E
480	
M100048TAC5M	 CWA	1080	 2.30	 410	 6	 4	PC3	 2.85	 4.75	 24	480	 n/a	 n/a	 1.91x2.91	 3.9	 22.0	
n/a	
n/a	
D
(1) 1500 WATT M48 METAL HALIDE LAMP			
120 or				
13.70		
40
277 or	M1500TRIAC5M	CWA	1610	 6.00	 460	 20	 17	PC3	 4.38	 6.38	 32	525	 n/a	 n/a	 1.96x3.65	3.88	 29.5	
n/a	
n/a	
G
347				4.70		 15
120 or				14.30		 40														 F
208 or	 M1500MLTAC5M	CWA	1615	8.30	 455	25	48	PC3	 4.4	 6.4	 32	 525	 n/a	 n/a	 1.96x3.65	 3.88	 30.0	
n/a	
n/a	G
240 or				
7.20		
20														F
277				
6.20		
20														E
480	 M150048TAC5M	CWA	1620	 3.50	 445	 10	 15	PC3	 4.4	 6.4	 32	525	 n/a	 n/a	 1.96x3.65	3.88	 30.0	
n/a	
n/a	
E

HID
CORE & COIL

See page 4-19 for Reference
Drawings and Wiring Diagrams.

PAGE 4-18

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID CORE & COIL BALLASTS

MH

METAL HALIDE

DESCRIPTION	

SUFFIX *

For Ballast Only	
For Bracket Only (see pg. 5-7)	
For Capacitor Only (see pg. 5-5, 5-6)	
For Distributor Replacement Kit
(see pg. 5-13 thru 5-15)	
For Canadian Distributor
Replacement Kit (see pg. 5-16)	
For Dry-Capacitor & Ballast
(see pg. 5-6)	
For Bracket & Capacitor
(see pg. 5-5, 5-7)	
For Bracket & Dry-Capacitor
(see pg. 5-6, 5-7)	

REFERENCE DRAWING PC1

000
200
500

W

S

M
L

500K

	BRef. Dwg.	
	
1	
	 PC1	
	 PC2	
	 PC3	

502K
518
700

L	
W	
M	
S
4.00”	0.75”	 3.35”	 0.25”
5.25”	1.25”	 4.60”	 0.25”
7.75”	2.75”	 6.10”	 0.25”
7.75”	2.75”	 6.10”	 0.25”

See p. 5-7 for adjustable mounting brackets and detailed bracket drawings.

718

REFERENCE DRAWING PC2

REFERENCE DRAWING PC3

4 Holes Cleared
for #10 Thru-Bolts

4 Holes Cleared
for #10 Thru-Bolts

8 Holes Cleared
for #10 Thru-Bolts

A

A
B
MAX

A
B
MAX

B
MAX

2.812˝

2 Holes Cleared
for #10 Thru-Bolts

2.438˝

Bracket

3.500˝ 3.938˝

4.250˝

2 Holes Cleared
for #10 Thru-Bolts

3.875˝

2 Holes Cleared
for #10 Thru-Bolts

4.250˝

4.375˝ 4.750˝

3.875˝

4.375˝
5.375˝ 5.750˝

WIRING DIAGRAMS
Wiring Diagram 1

Wiring Diagram 2

Wiring Diagram 3

Wiring Diagram 4

Wiring Diagram 5

Wiring Diagram 6

HID
CORE & COIL

Wiring Diagram 16

Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances

PAGE 4-19

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

PULSE START
MH

35/39-100 WATT

HID CORE & COIL BALLASTS
PULSE START METAL HALIDE

• 6 0 Hz
• Minimum starting temperature: -30° C
• Normal and High Power Factor models available

					
Nom				 Dimensions				
Capacitor				
Ignitor
				Max	Open												 Total		 Max	 UL
Input	Catalog*	 Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Oil Filled		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 35/39 WATT M130 METAL HALIDE LAMP
120 or				
.84		
2
277 or 	
M35TRILC3M	 HX-HPF	 54	
.40	
235	
1	
9	 PC1	 0.85	
2.15	 5	 300	 1.26	
2.36	 1.31x2.16	 2.2	
1.7 	
MH100-3A	
5	
A
347				.30		 1	

120 or				.82		 2
208 or	
	.48	 	1	
M35MLTLC3M	 HX-HPF	50
230
10	PC1	 0.85	 2.0	 5	 277	 1.26	 2.83	 1.31x2.16	 2.2	
240 or				.42		 1
277				.36		 1
(1) 50 WATT M110 METAL HALIDE LAMP — Medium Base
120 or				
1.30		
3
277 or 	 M50TRILC3M	 HX-HPF	67	 .61	 250	 2	 9	PC1	 1.05	 2.55	 6	 300	 1.26	 2.83	 1.31x2.16	 2.2	
347				.48		 2
1.25		
3	
				
120 or				
208 or	
	0.70	 	3	
255
10	PC1	 1.05	 2.40	 6	 300	 1.26	 2.83	 1.31x2.16	 2.2	
M50MLTLC3M	 HX-HPF	65
240 or				
0.60		
2
277				0.55		 2

1.7	

MH100-3A	

	

5	

A

4.25	 MH100-3A	 10	

A

3.6	

A

MH100-3A	 10	

HID
CORE & COIL

(1) 70 WATT M98 / M143 (C98) METAL HALIDE LAMP - Medium Base
120 or				1.85		 4
277 or	
M70TRILC3M 	 HX-HPF	 91	
0.80	
260	
2	
9	 PC1	 1.5	
2.65	 8	 280	 1.65	
2.83	 1.31x2.16	 2.2	
5.0	
MH100-3A	
10	
A
347				0.65		 2
120 or					
1.70	
4																	
208 or
	1.00	 	3	
	
M70MLTLC3M 	
HX-HPF	90
255
10	PC1	 1.30	 2.65	 8	 280	 1.65	 2.83	 1.31x2.16	 2.2	 4.5	 MH100-3A	 10	
A
240 or				
0.85		2														
277				
0.75		2														
480	
M7048TLC3M	 HX-HPF	95	 0.45	 260	 1	 8	PC1	 1.35	 2.80	 8	 300	 1.65	 2.83	 1.31x2.16	 2.2	 4.2	 MH100-3A	 10	
E
(1) 70 WATT M85 METAL HALIDE LAMP - Double Ended			
120 or 				
1.70		4														
208 or	
	1.00	 	3
A
255
	 10	PC1	 1.30	 2.65	 8	 280	 1.65	 2.83	 1.31x2.16	 4.5	 4.25	 MH70-3B	 10	
M70MLTLC3D 	 HX-HPF	90
240 or 				
0.85		2														
277				0.75		 2
(1) 100 WATT M90 / M92 / M140 METAL HALIDE LAMP - Medium Base			
120 or				
2.60		
7				
277 or	
M100TRILC3M 	 HX-HPF	 129	
1.15	
265	
3	
9	 PC1	 1.6	
2.95	 12	 280	 1.65	
2.83	 1.31x2.16	 3.13	
5.5	
MH100-3A	
10	
A
347				0.90		 3		
120 or	
	2.60	 	8	
C
1.55		
5														C
208 or				
M100MLTLC30	 HX-HPF	127
260
10	PC1	 1.5	 2.8	 12	 280	 1.65	 2.83	 1.31x2.16	 n/a	 4.5	 MH100-3A	 10	
240 or				
1.30		4														B
277				
1.15		4														B	
480	
M10048TLC3M	 HX-HPF	 132	
0.62	
285	
2	
8	 PC1	 1.7	
3.0	 10	 300	 1.65	
2.83	 1.31x2.16	 2.7	
5.5	
MH100-3A	
10	
C	
(1) 100 WATT M91 METAL HALIDE LAMP - Double Ended
120 or	
	2.60	 	8	
C
208 or				
1.55		
5														C	
M100MLTLC3D	 HX-HPF	127
260
10	PC1	 1.5	 2.8	 12	 280	 1.65	 2.83	 1.31x2.16	 3.13	 4.5	 MH70-3B	 10	
240 or				
1.30		4														B
277				
1.15		4														B
3

See page 4-26 for Reference
Drawings and Wiring Diagrams.

Capacitors are available as an option for high power
factor operation.

PAGE 4-20

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID CORE & COIL BALLASTS
PULSE START METAL HALIDE

• 60 Hz
•M
 inimum Starting Temperature: -40° C
• F eature CWA Design

PULSE START
MH
150-200 WATT

HID
CORE & COIL

					
Nom				 Dimensions				
Capacitor				
Ignitor
				Max	Open												 Total		 Max	 UL
Input	Catalog*	
Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Oil Filled		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 150 WATT M102/M142 METAL HALIDE LAMP - Medium Base			
	RX-NPF	 	
	
	
		
277	M150277RCEM
171
0.65
277	 4	 7	 5	 2.52	 3.80	 14	280
1.65
2.83
n/a	 n/a	 4.0	 MH100-1A	3	 B
RX-HPF	 		
		
	
	
	
	
	
						
120 or				
3.32		
10				
277 or	
M150TRILC3M 	 HX-HPF	 185	
1.48	
245	
4	
9	 PC1	 2.38	
3.65	 16	 280	 1.65	
2.83	 1.56x2.69	 2.7	
7.25	
MH100-3A	
10	
D
347				 0.65		 2				
120 or				
3.40		
10				
208 or	 M150MLTLC3M	 HX-HPF	185	1.93	 260	5	
10	PC1	 2.38	 3.7	 16	 280	 1.65	 2.83	 1.56x2.69	 2.7	 7.0	 MH100-3A	 10	
A
240 or				
1.70		
5				
277				 1.50		 4				
120 or				
1.60		4														C
208 or	 M150MLTAC3M	
CWA	 188	
1.00	
210	
3	
1	 PCI	 2.5	
3.75	 16	 330	 1.65	
3.82	
n/a	
n/a	
7.1	
MH150-1A	
10	
D
0.80		3														C
240 or				
277				
0.70		2														C	
480	
M15048TLC3M 	 HX-HPF	 185	
1.00	
260	
3	
8	 PC1	 2.3	
3.6	 16	 280	 1.65	
2.83	 1.56x2.69	 2.7	
7.0	
MH100-3A	
10	
F
(1) 150 WATT M81 METAL HALIDE LAMP - Double Ended			
120 or				
3.40		
10				
208 or
	1.95	
	5	
	 M150MLTLC3D	 HX-HPF	185
260
10	PC1	 2.38	 3.70	 16	 280	 1.65	 2.83	1.56x2.69	 2.7	 7.0	 MH70-3B	 10	
A
1.70		
5
240 or				
277				1.50		 4
(1) 175 WATT M152 / M137 METAL HALIDE PULSE START LAMP (4” FRAME)			
	RX-NPF	 	1.25	
	n/a	 n/a	 n/a	 n/a
277	P175277RCEM
199
277	 3	 7	 5	 2.5	 3.6	 12	280
	 3.9	 MH350-1A	10	 C
	
	
RX-HPF	 	
2.00	
	
	
	
					
1.65	 2.83	 1.31x2.16	 3.9 	
120 or				2.00		 5												
277 or	 P175TRIAC3M	 CWA	 208	 0.90	
310	
2	
3	 PC1	 2.5	
3.6	 10	 400	 1.65	 2.83	 1.31x2.16	 3.9	
6.75	 MH350-1A	 10	
B
347				0.70		 2
120 or				2.09		 5														 	
208 or	 P175MLTAC3M	 CWA	208	1.26	 306	3	1	 PC1	 2.5	 3.6	 10	400	 1.65	 2.83	1.31x2.16	 3.9	 6.75	 MH350-1A	 10	
A
240 or				1.02		 3														
277				0.96		 2
120 or				
1.95		
5	
208 or	 P175MLTAC3L	 CWA	 198	 1.10	
285	
3	
1	 PC1	 3.10	
4.20	 11	 370	 1.65	 2.83	
n/a	
n/a	
8.5	
MH350-1A	 2	
A
240 or				
1.00		
3
277				0.80		 2								
120 or				1.80		 5														
208 or				1.05		 3														
240 or	 P175ML5AC3M	 CWA	 210	 0.90	
295	
3	
4	 PC1	 2.65	
4.0	 10	 400	 1.65	 2.83	 1.91x2.91	 2.7	
8.0	
MH350-1A	 10	
B
277 or				0.80		 2														
480				0.45		 2														
480	 P17548TAC3L	 CWA	 198	 0.50	 285	 2	 2	PC1	 3.10	 4.20	 11	360	 1.65	 2.83	 n/a	 n/a	 8.5	 MH350-1A	 2	
A
(1) 175 WATT M152/M137 METAL HALIDE PULSE START LAMP (5” FRAME)			
120 or				1.70		 5														 	
208 or	 P175MLTAC4L	 CWA	198	0.95	 270	3	1	 PC2	 1.77	 3.3	 12.5	330	 1.65	 2.83	 n/a	
n/a	 9.45	 MH350-1A	 10	
A
240 or				0.85		 3														
277				0.75		 2														
480	 P17548TAC4L	 CWA	 198	 0.40	 275	
2	 4	 PC2	 1.80	 3.5	 12.5	330	 1.65	 2.83	 n/a	
n/a	 9.6	 MH350-1A	 10	
A

See page 4-26 for Reference
Drawings and Wiring Diagrams.

PAGE 4-21

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

PULSE START
MH
200-320 WATT

HID CORE & COIL BALLASTS
PULSE START METAL HALIDE

• 60 Hz
• Minimum Starting Temperature: -40° C
• CWA and High Power Factor Models Available

HID
CORE & COIL

					
Nom				 Dimensions				
Capacitor				
Ignitor
				Max	Open												 Total		 Max	 UL
Input	Catalog*	
Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Oil Filled		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 200 WATT M136 METAL HALIDE PULSE START LAMP			
	
	
	
	
	
	
	
	
	
	
	
277	P200277RCEM RX-HPF 218 1.35
277	 4	 7	5
1.06	 2.82	 13	280 1.65
3.83
n/a
n/a
4.7
MH350-1A	10	 A
120 or				2.70		 6				
277 or	 P200TRIAC3M	 CWA	 240	 1.04	 310	 3	 3	PC1	 2.75	 3.95	 11	400	 1.65	 2.83	 2.7	 3.6	 8.0	 MH350-1A	 10	
C
347				0.87		 3
120 or				
2.10		
7	
208 or				
1.22		
5
240 or	 P200MLTAC3L	 CWA	 227	 1.05	
245	
4	
1	 PC1	 2.90	
4.25 	 15	 330	 1.85	 3.82	
n/a	
n/a	
9.0	
MH100-5A	 10	
A
277				0.95		 4
(1) 200 WATT M136 METAL HALIDE PULSE START LAMP			
120 or				
2.66		
6	
208 or				
1.52		
4
240 or	 P200ML5AC3M	 CWA	 233	 1.31	
303	
3	
2	 PC1	 2.75	
4.30	 11	 400	 1.65	 2.83	
n/a	
n/a	
8.0	
MH350-1A	 10	
C
277 or				
1.12		
3
480				0.68		 2
480	
A
P20048TAC3L	 CWA	 227	 0.50	 245	 2	 4	PC1	 2.9	 4.25	 15	330	 1.85	 3.82	 n/a	 n/a	 9.0	 MH100-5A	 10	
(1) 250 WATT M153 METAL HALIDE PULSE START LAMP 			
	RX-NPF	 	2.00		 5
	n/a	 n/a	 n/a	 n/a
277	P250277RCEM
278
	 7	 5	 1.06	 2.82	 17.5	280
	 4.8	 MH350-1A	10	 A
277
	
	
RX-HPF	 	
1.85	
	 5							 1.6	 3.82	1.56x2.69	 3.1
120 or				
2.35		
8				
277 or	 P250TRIAC4M	 CWA	 300	 1.15	 292	 3	 3	PC2	 1.36	 3.36	 14	400	 1.6	 3.782	 2.3	 4.0	 9.0	 MH350-1A	 10	
A
347				.098		 3
120 or				
2.40		
8				
	
208 or	 P250MLTAC4L	 CWA	283	1.40	 270	5	1	PC2	 2.05	 3.90	 17	330	 1.65	 3.82	 n/a	 n/a	 11.0	 MH350-1A	 15	
A
240 or				
1.20		
5				
277				 1.05		 3				
120 or				
2.50		
8
208 or				
1.40		
5
240 or	 P250ML5AC4L	 CWA	 283	 1.25	
270	
5	
2	 PC2	 1.85	
3.75	 17	 330	 1.65	
3.82	
n/a	
n/a	
10.5	
MH350-1A	 10	
A
277 or				
1.05		
3
480				0.60		 2
480	 P25048TAC4L	 CWA	 283	 0.60	 275	 2	 4	PC2	 1.9	 3.6	 17	360	 1.65	 3.82	 n/a	 n/a	 10.0	 MH350-1A	 10	
A
(1) 320 WATT M132 / M154 METAL HALIDE PULSE START LAMP 			
	RX-NPF	 	3.70	
	10
	n/a	 n/a	 n/a	 n/a
277	P320277RCEM
348
277
	 7	 5	 1.5	 3.28	 22.5	280
	 6.8	 MH350-1A	10	 A
	
	
RX-HPF	 	
2.34		
6							
1.865	 3.115	
n/a	
n/a
120 or				
3.85		
8				
277 or	 P320TRIAC4M	 CWA	 370	 1.70	 280	 4	 3	PC2	 2.0	 3.73	20.5	360	 1.85	 3.82	1.91x2.91	 3.1	 11.0	 MH350-1A	 10	
C
347				1.30		 3
120 or				
3.10		9														B
A
208 or	 P320MLTAC40	 CWA	364	1.80	 275	5	1	 PC2	 2.0	
3.9	 21.0	360	 1.85	 3.82	 1.91x2.91	 3.1	 11.0	 MH350-1A	 10	
240 or				
1.55		5														B
277				
1.35		4														A
120 or				
4.00		
10														D
208 or				
2.40		7														C
D
240 or	P320ML5AC4M	 CWA	 370	 2.10	 280	 5	 2	PC2	 2.0	 3.86	20.5	360	 1.8	 3.82	1.91x2.91	 3.6	 11.3	 MH350-1A	 10	
277 or				
1.85		5														D
480				
1.00		3														C

See page 4-26 for Reference
Drawings and Wiring Diagrams.

PAGE 4-22

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID CORE & COIL BALLASTS
PULSE START METAL HALIDE

• 60 Hz
• Minimum Starting Temperature: -40° C
• Feature CWA Design

PULSE START
MH
320-350 WATT

Capacitor				
Ignitor
					
Nom				 Dimensions				
				Max	Open												 Total		 Max	 UL
Oil Filled		
Input	Catalog*	
Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 320 WATT M132 / M154 METAL HALIDE PULSE START LAMP 			
120 or				
3.10		8														
208 or				
1.80		5														
240 or	 P320ML5AC4L	 CWA	 363	 1.55	
275	
5	
2	 PC2	 1.88	
3.8	 21	 360	 1.85	
3.82	
2.91	
3.13	
12.0	
MH350-1A	 10	
A
277 or				
1.35		4														
480				0.80		 3
480	
CWA	 364	 0.80	 280	 3	 4	PC2	 2.0	 3.9	 21	360	 1.85	 3.82	 2.91	 3.13	 11.0	 MH350-1A	 10	
A
P32048TAC4L	
(1) 350 WATT M131 METAL HALIDE PULSE START LAMP			
										
RX-NPF
	3.80	
	10
—	—	—	—
277	
	377
277
	 7	 5	 1.5	 3.28	 22.5	280	
	 6.8	 MH350-1	10	 A
P350277RCEM	
		
RX-HPF		
2.35		
6					
	
	
1.65	 3.82	 1.56x2.69	 3.9
120 or				
4.85		
10				
277 or	
P350TRIAC4M	
CWA	
405	
1.70	280	5	3	
PC2	
2.0	4.0	
21	
360	
1.85	3.82	2.9	3.1	11.5	
MH350-1A	
10	 C
347				1.30		 3
120 or				3.40		 9														
208 or	 P350MLTAC4M
	2.00	
	6	
	
	 CWA	400
275
1	
PC2	
2.0	3.9	
22	
360	
n/a	n/a	2.7	3.9	11.0	
MH350-1A	
10
C
240 or				1.70		 5														
277				1.45		 4														
120 or	
	3.25	
	9														B
208 or				
1.80
6	
1	 PC2	 1.92	
3.95	 22.5	 345	 1.85	 3.82	
n/a	
n/a	
10.0	 MH350-1A	 10	
B
		
P350MLTAC4O	 CWA	397
270
240 or				
1.60
C
	 5														
277				1.40		 4														 C
120 or				3.35		 9														
208 or				1.85		 6														
240 or	 P350ML5AC4O	 CWA	 397	 1.65	
280	
5	
4	 PC2	 2.2	
4.25	 22.5	 345	 1.85	 3.82	
n/a	
n/a	
12	
MH350-1A	 10	
B
277 or				1.40		 4														
480				0.80		 3														
120 or				
3.35		
10														
208 or				1.90		 7														
240 or	
P350ML5AC4L	
CWA	
397	
1.65	275	 9	4	
PC2	
1.88	3.8	
22	
360	
1.85	3.82	2.69	3.9	12.0	MH350-1A	10	 B
277 or				1.45		 5														
480				0.85		 3														
480	 P35048TAC4O	 CWA	 398	 0.85	 280	
3	 4	 PC2	 2.00	 3.95	 22.5	345	 1.85	 3.82	 n/a	
n/a	 11.0	 MH350-1A	 10	
D
480	P35048TAC4L	CWA	
397	
0.85	280	 3	4	
PC2	
2.00	3.9	
22	
360	
1.85	3.82	2.69	3.9	11.0	MH350-1A	10	 C

See page 4-26 for Reference
Drawings and Wiring Diagrams.

HID
CORE & COIL
See page 5-29 for Reference
Drawings and Wiring Diagrams.
PAGE 4-23

PULSE START
MH
400 WATT

HID CORE & COIL BALLASTS
PULSE START METAL HALIDE

• 60 Hz
•M
 inimum Starting Temperature: -40° C
•C
 WA and High Power Factor Models Available

					
Nom				 Dimensions				
Capacitor				
Ignitor
				Max	Open												 Total		 Max	 UL
Input	Catalog*	
Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Oil Filled		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 400 WATT M155 / M135 / M128 / M172 METAL HALIDE PULSE START LAMP			
120 or				
4.05		
10				
277 or	 P400TRIAC4M	 CWA	 454	 1.75	
285	
5	
3	 PC2	 2.0	
3.9	 24	 400	 1.85	 3.82	 1.91x2.91	 3.1	
12 	 MH350-1A	 10	
D
347				1.40		 4
120 or				
3.90		
10														B
208 or	 P400MLTAC4L	 CWA	 454	 2.25	
280	
7	
1	 PC2	 2.30	
4.20	 26	 330	 1.85	 3.82	
n/a	
n/a	
11	
MH350-1A	 10	
B
240 or				1.95		 5														 B
277				1.70		 5														 C
120 or				
3.90		
10
208 or				
2.25		
7
240 or	 P400ML5AC4M	 CWA	 457	 1.95	
285	
5	 26	 PC2	 2.0	
3.9	 24	 400	 1.85	 3.82	 1.91x2.91	 3.1	
12.5	 MH350-1A	 10	
D
277 or				
1.70		
5
480				0.95		 3
120 or				
3.90		
10														C
208 or				2.25		 7														 D
240 or	 P400ML5AC4L	 CWA	 454	 1.90	
280	
5	
2	 PC2	 2.35	
4.25	 26	 330	 1.85	 3.82	 1.91x2.91	 3.1	
12	
MH350-1A	 10	
C
277 or				1.65		 5														 C
480				0.95		 3														 D
480	
P40048TAC4L	 CWA	 454	 1.00	 285	 3	 4	PC2	 2.35	 4.25	 26	330	 1.85	 3.82	 n/a	 n/a	 12.5	 MH350-1A	 10	
D	
480	
P40048TAC4M	 CWA	 457	 1.00	 285	 3	 4	 PC2	 2.0	 3.9	 24	400	 1.85	 3.82	1.91x2.91	 3.1	 12	 MH350-1A	 10	
D

HID
CORE & COIL

See page 4-26 for Reference
Drawings and Wiring Diagrams.

PAGE 4-24

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID CORE & COIL BALLASTS
PULSE START METAL HALIDE

• 60 Hz
•M
 inimum Starting Temperature: -40° C
•C
 WA and High Power Factor Models Available

PULSE START
MH
450-1000 WATT

See page 4-26 for Reference
Drawings and Wiring Diagrams.

PAGE 4-25

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID
CORE & COIL

					
Nom				 Dimensions				
Capacitor				
Ignitor
				Max	Open												 Total		 Max	 UL
Input	Catalog*	
Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Oil Filled		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 450 WATT M144 METAL HALIDE PULSE START LAMP			
120 or				
4.35		
10														B
208 or
	2.55	
	8	
C
280
1	 PC2	 2.25	 4.0	 26.5	400	 1.85	 4.76	 1.91x2.91	 3.9	 13.0	 MH350-1A	 10	
	 P450MLTAC4L	 CWA	508
240 or	
			
2.15		
7														
C
277				
1.90		
5				
									
C
120 or				
4.10		
12														C
208 or				2.35		 8														 B
240 or	 P450ML5AC4L	 CWA	 508	 2.05	
280	
7	
2	 PC2	 2.65	
4.55	 26.5	 360	 1.85	 4.76	 1.91x2.91	 3.9	
15.5	
MH350-1	
10	
C
277 or				1.85		 5														 C
480				1.05		 4														 B	
480	 P45048TAC4L	 CWA	 511	 1.05	 277	 3	 4	 PC2	 2.40	 4.25	 26.5	360	 1.85	 4.76	 1.91x2.91	 3.9	 14.5	 MH350-1A	 10	
D
(1) 750 WATT M149 METAL HALIDE PULSE START LAMP			
120 or				
7.05		
15														B
277 or	 P750TRIAC5M	 CWA	 820	 3.05	
340	
8	
3	 PC3	 2.8	
4.6	 28	 400	 n/a	
n/a	 1.91x2.91	 3.88	 18.0	
P750-1B	
10	
C
347				2.45		 8														 C
120 or				
7.10		
18														D
A
208 or
	4.10	
	10	
340
1	PC3	 2.8	 4.8	 28	400	 n/a	 n/a	 1.91x2.91	3.88	 18.0	 P750-1B	 10	
	 P750MLTAC5M	 CWA	825
240 or				
3.55		
10														B
277				3.10		 8														 B
120 or				
6.95		
18														C
208 or				
4.00		
10														C
240 or	 P750ML5AC5M	
CWA	 820	 3.50	
340	
10	
2	 PC3	 2.8	
4.9	 28	 400	
n/a	
n/a	 1.91x2.91	 3.88	19.0	 P750-1B	 15	 D
277 or				
3.00		8														D
480				
1.75		5														C
480	 P75048TAC5M	 CWA	 822	 1.80	 335	 5	 4	PC3	 2.8	 4.75	 28	400	 n/a	 n/a	 1.91x2.91	3.88	 18.0	 P750-1B	 10	
D
(1) 875 WATT M166 METAL HALIDE PULSE START LAMP			
120 or				
7.90		
20														D
C
208 or
	4.55	
	15	
395
1	PC3	 2.8	 4.8	 24	480	 n/a	 n/a	 1.91x2.91	 3.9	 17.5	 HPS1000-4B	 10	
	 P875MLTAC5M	 CWA	945
240 or				
3.95		
10														A
277				
3.45		
10														C
(1) 1000 WATT M141 METAL HALIDE PULSE START LAMP			
120 or				
9.00		
20																
208 or
	5.20	
	15	
420
1	 PC3	 2.9	
5.05	 24	 480	 n/a	
n/a	 1.91x2.91	 3.9	
22.0	 HPS1000-4B	 20	
D
	 P1000MLTAC5M	 CWA	1080
4.50		
10														
240 or				
277				
3.90		
10														
120 or				
8.95		
20														G
208 or				
5.15		
15														B
240 or	P1000ML5AC5M	 CWA	1080	 4.45	 420	 10	 2	PC3	 2.9	 5.05	 24	480	 n/a	 n/a	 1.91x2.91	 3.9	 22.0	 HPS1000-4B	 20	
C
277 or				
3.85		
10														C
480				
2.25		
10														C
480	 P100048TAC5M	 CWA	1080	 2.30	 410	 6	 4	PC3	 2.85	 4.75	 24	480	 n/a	 n/a	 1.91x2.91	 3.9	 18.0	 HPS1000-4B	 15	
D2

PULSE START
MH

HID CORE & COIL BALLASTS
PULSE START METAL HALIDE

DESCRIPTION	

SUFFIX *

For Ballast Only	
For Bracket Only (see pg. 5-7)	
For Capacitor Only (see pg. 5-5, 5-6)	
For Distributor Replacement Kit
(see pg. 5-13 thru 5-15)	
For Canadian Distributor
Replacement Kit (see pg. 5-16)	
For Dry-Capacitor & Ballast
(see pg. 5-6)	
For Bracket & Capacitor
(see pg. 5-5, 5-7)	
For Bracket & Dry-Capacitor
(see pg. 5-6, 5-7)	

000
200
500

REFERENCE DRAWING PC1

REFERENCE DRAWING PC2

4 Holes Cleared
for #10 Thru-Bolts

4 Holes Cleared
for #10 Thru-Bolts
A

A

B
MAX

B
MAX

2.812˝

2 Holes Cleared
for #10 Thru-Bolts

500K
502K

3.875˝

2.438˝

3.500˝ 3.938˝

4.250˝

2 Holes Cleared
for #10 Thru-Bolts

4.375˝ 4.750˝

518
700

REFERENCE DRAWING PC3

718

REFERENCE DRAWING 5

8 Holes Cleared
for #10 Thru-Bolts
A
B
MAX

W

Bracket

2 Holes Cleared
for #10 Thru-Bolts

S

M
L

	BRef. Dwg.	
	 PC1	
	 PC2	
	 PC3	
	 RX1	

4.250˝

L	
W	
M	
S
5.25”	1.25”	 4.60”	 0.25”
7.75”	1.25”	 5.75”	 0.25”
7.75”	2.75”	 6.10”	 0.25”
4.00”	0.75”	 3.35”	 0.25”

3.875˝

4.375˝
5.375˝ 5.750˝

See p. 5-7 for adjustable mounting brackets and detailed bracket drawings.

HID
CORE & COIL

WIRING DIAGRAMS
Wiring Diagram 1

Wiring Diagram 2

Wiring Diagram 3

Wiring Diagram 4

Wiring Diagram 7

Wiring Diagram 8

Wiring Diagram 10

Wiring Diagram 9

Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances

PAGE 4-26

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUM

HPS
35-100

• 60 Hz
• Minimum Starting Temperature: -40° C
• Normal and High Power Factor Models

WATT

1

Also can be used on a 277 volt line in conjuction with the step down transformers
Capacitors are available as an option for High Power Factor operation
◆
Ballast has built-in starter.
3

PAGE 4-27

See pages 4-31 and 4-32 for
Reference Drawings and Wiring Diagrams.

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID
CORE & COIL

					
Nom				 Dimensions				
Capacitor				
Ignitor
				Max	Open												 Total		 Max	 UL
Input	Catalog*	
Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Oil Filled		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 35 WATT S76 HIGH PRESSURE SODIUM LAMP			
	
	0.65	
2	
	HPS150-3A
1201	1233-251W ◆ R-HPF 3	43
120	
11	 1	 0.63	 2.0	 14	120	 1.87	 2.25	1.56x2.69	 2.7	 1.5
	3	 A
	
				1.15		 3												Permanently Attached	
	RX-NPF	 	0.85	 120	 2	
120	S35120RCEM
44
7	 5	 0.55	 1.75	 14	220	 1.87	 2.25	 1.9	 2.3	 1.2	 HPS150-3A	 10	
A
		 RX-HPF		0.65		 3							
(1) 50 WATT S68 HIGH PRESSURE SODIUM LAMP			
	0.90	
3	
	HPS150-3A
1201	
1233-35W ◆	R-HPF 3	60
120	
11	 1	 0.94	 2.40	 20	120	 1.65	 2.83	1.56x2.69	 3.1	 2.0
	3	 A
				1.50		 5												Permanently Attached
	RX-NPF	 	0.90	 	3	
120	S50120RCEM
60
120
7	 5	 0.83	 1.95	 20	240	 1.87	 2.25	 1.9	 2.3	 1.5	 HPS150-3A	 3	
A
		
RX-HPF		 1.10		
4
120 or				
1.24		
5
208 or
	0.60	 	3	
130
10	
PC1	
1.3	2.7	
5	
300	
1.2	2.2	2.2	2.2	4.1	HPS150-3A	
5	 A
S50MLTLC3M	 HX-HPF	66
240 or				
0.52		
3
277				0.45		 2
(1) 70 WATT S62 HIGH PRESSURE SODIUM LAMP			
	1.30	
8	
	HPS150-3A
120	1233-142W ◆	 R-HPF 	83
120	
11	 1	 1.32	 2.7	 2.8	120	 1.65	 4.75	 n/a	 n/a	 2.5
	3	 A
Permanently Attached	
				
2.10		8												
	RX-NPF	 	1.30	 	4	
120	S70120RCEM
82
120
7	 5	 1.10	 2.25	 28	120	 1.87	 2.25	 1.3	 2.7	 2.0	 HPS150-3A	 3	
A
		
RX-HPF		 210		 6
120 or				
1.50 		
4														
B
277 or	 S70TRILC3M 	 HX-HPF	 94	 0.65	 120	 2	 9	 PC1	 1.38	 2.7	 7	 280	 1.65	 2.83	1.31x2.16	 2.2	 4.4	 HPS150-3A	 10	
A
347				
0.50		
2	
	
	
	
										
A
120 or				1.50		 5														
208 or	 S70MLTLC3M	 HX-HPF	98	0.88	 120	3	10	PC1	 1.38	 2.74	 7	 280	 1.65	 2.83	1.31x2.16	 2.2	 4.1	 HPS150-3A	 10	
B
240 or				0.75		 3														
277				0.65		 2
480	
S7048TLC3M	 HX-HPF	94	 0.34	 120	 2	 8	 PC1	 1.85	 3.0	 7	 280	 1.65	 3.00	1.31x2.16	2.2	 6.0	 HPS150-3A	 10	
A
(1) 100 WATT S54 HIGH PRESSURE SODIUM LAMP			 -	1.80	
5	
	HPS150-3A
120 1	
1233-10W ◆	 R-HPF 3	114
120	
11	 1	 1.5	 2.9	 40	120	 1.87	 2.78	 1.87	 2.9	 2.8
	3	 A
				2.90		 8												Permanently Attached	
	RX-NPF	 	2.90	 	8	
120	S100120RCEM
115
120
7	 5	 1.50	 2.75	 40	120	 1.87	 2.78	 1.8	 2.7	 2.0	 HPS150-3A	 10	
A
		
RX-HPF		 1.80		 5
120 or				2.20		 8				
277 or	 S100TRILC3M 	 HX-HPF	 130	 0.95	
120	
3	
9	 PC1	 2.0	
3.5	 10	 330	 1.2	
2.7	 1.31x2.16	 2.7	
5.9	 HPS150-3A	 10	
B
347				0.69		 2				
120 or				2.20		 7														
208 or	 S100MLTLC3M	 HX-HPF	122	 1.30	
120	5	10	PC1	 2.0	 3.36	 10	 280	 1.26	 2.83	1.31x2.16	 2.7	 6.0	 HPS150-3A	 10	
B
240 or				1.10		 3														
277				0.95		 3
480	
S10048TLC3M	 HX-HPF	132	 0.57	 120	
2	 8	 PC1	 2.0	
3.3	 10	 280	 1.26	 2.83	 1.31x2.16	 2.2	
6.0	 HPS150-3A	 5	
E

HPS
150-250

HID
CORE & COIL

WATT

HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUM

• 60 Hz
• Minimum Starting Temperature: -40° C
• CWA, Normal and High Power Factor Models

					
Nom				 Dimensions				
Capacitor				
Ignitor
				Max	Open												 Total		 Max	 UL
Input	Catalog*	
Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Oil Filled		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 150 WATT S55 HIGH PRESSURE SODIUM LAMP		
	
	2.35	
6	
	HPS150-3A	
1233-154W ◆	R-HPF 3	170
120 1
120	
11	 1	 2.0	 3.4	 52	240	 1.85	 3.82	 2.12	 2.9	 3.5
3	A
Permanently Attached	
				
4.40		
12												
	RX-NPF	 	2.35	
12
120	S150120RCEM
170
120	
	 7	 5	 2.0	 3.05	 50	120	 1.87	 n/a	 2.0	 2.9	 3.25	 HPS150-3A	 3	
A
		
RX-HPF		 4.40		 6
120 or	
	3.10	 	10	
	
	B
S15027TLC3M	 HX-HPF	188
120
12	PC1 2.5	 3.85	 14	280	 1.65	 2.83	 1.56x2.69	2.7	 7.0	 HPS150-3A	 10
277				1.30		 5														A
120 or				
3.00		
10														B	
277 or	 S150TRILC3M	 HX-HPF	188	 1.35	 120	 5	 9	 PC1	 2.38	 3.68	 14	 300	 1.6	 2.8	 1.56x2.69	 2.7	 7.0	 HPS150-3A	 10	
C
347				
1.00		4														B
120 or				
3.00		
10														E
208 or	 S150MLTLC3O	 HX-HPF	188	1.65	 120	5	10	PC1	 2.5	 3.85	 14	 280	 1.6	 2.8	 2.7	 2.7	 7.0	 HPS150-3A	 10	D
240 or				
1.50		5														E
277				
1.30		4														D
480	
S15048TLC3M	 HX-HPF	189	 0.72	 120	 2	 8	 PC1	 3.0	 4.5	 14	 280	 1.6	 2.83	 1.56x2.69	 2.7	 8.75	 HPS150-3A	 10	
D
(1) 200 WATT S66 HIGH PRESSURE SODIUM LAMP			
120	
	
	
	
2.00	
	
7	
	
	
											
277	 S200TRIAC4M	 CWA	 240	 0.86	 184	 3	 3	PC2	 1.45	 3.25	 28	280	 1.65	 4.76	1.91x2.91	 3.1	 8.65	 HPS400-3A	 10	
C
347	
	
	
	
0.68	
	
3	
	
	
											
120 or				
2.10		7														
208 or	
	
	1.20	 	4	
CWA	240
175
1	PC2	 1.2	 3.0	 28	280	 1.65	 4.76	1.91X2.91	 3.1	 8.5	 HPS400-3A	 10	
S200MLTAC4M
B
240 or				
1.00		4														
277				0.88		 4
480	 S20048TAC4M	 CWA	 240	 0.56	 172	 2	 4	PC2	 1.2	 3.0	 28	280	 1.65	 4.76	1.91x2.91	 3.1	 8.5	 HPS400-3A	 10	
C	
(1) 250 WATT S50 HIGH PRESSURE SODIUM LAMP 			
120	 S250120AC4M	 CWA	 295	 2.50	 185	 8	 13	PC2	 1.8	 3.65	 35	 330	 n/a	 n/a	 1.8	 3.1	 10.3	 HPS400-3A	 10	
A
120 or				2.40		 7														 B
277 or	 S250TRIAC4M	 CWA	 295	 1.05	 185	 3	 3	 PC2	 1.8	 3.55	 35	240	 1.65	 3.82	1.91x2.91	 3.1	 10	 HPS400-3A	 10	
B
347				0.85		 3														 C
120 or				2.50		 7														
208 or
1.45
4
	
	S250MLTAC4M	 CWA	 295	
	190	 	 1	 PC2	 1.8	 3.55	 35	240	 1.65	 3.82	1.91x2.91	 3.1	 10	 HPS400-3A	 10
B
240 or				1.25		 4														
277				1.10		 3														
120 or				2.50		 8														 C
208 or				1.55	 	 4														 C
240 or	 S250ML5AC4O	 CWA	 300	 1.25	 188	 4	 2	 PC2	 1.95	 3.70	 35	240	 1.65	 3.82	1.91x2.91	 3.1	 11	 HPS400-3A	 10	
B
277 or				1.05		 3														 B
480				0.65		 2														 B
480	 S25048TAC4M	 CWA	 298	 0.65	 190	 2	 4	 PC2	 1.85	 3.65	 35	240	 1.65	 3.82	1.91x2.91	 3.1	 10	 HPS400-3A	 5	
A

See pages 4-31 and 4-32 for
Reference Drawings and Wiring Diagrams.

Ballast has built-in starter.
* Also can be used on a 277 volt line in conjunction with
the step-down transformers described on page 5-53.
3
Capacitors are available as an option for high power
factor operation.
◆

PAGE 4-28

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUMFEATURING MULTI-5™

•	60 Hz
•	Minimum Starting Temperature: -40° C
•	CWA, Normal and High Power Factors Models Available

HPS
400-430
WATT

					
Nom				 Dimensions				
Capacitor				
Ignitor
				Max	Open												 Total		 Max	 UL
Input	Catalog*	
Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Oil Filled		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP - 4 3/ ” Frame			
120 or				
3.95		
10				
277 or	 S400TRIAC4M	 CWA	 465	 1.70	 190	 5	 3	 PC2	 2.32	 4.1	 55	240	 1.77	 3.74	1.91x2.91	 3.5	 14.0	 HPS400-3A	 10	
D
347 				1.35		 4				
120 or				
3.80		
10														
208 or	
	2.20	
	6	
	
S400MLTAC4M	 CWA	463
190
1	 PC2	 2.32	 4.1	 55	240	 1.77	 3.74	1.91x2.91	 3.5	 14.0	 HPS400-3A	 10
D
240 or				1.90		 5														
277				1.90		 5														
120 or				
3.95		
10														
208 or				
2.30	
	
6														
240 or	 S400ML5AC4M	 CWA	 465	 2.00	
190 	
5	
2	 PC2	 2.44	
4.3	 55	 240	 1.77	 3.74	 1.91x2.91	 3.5	
14.0	 HPS400-3A	 10	
D
277 or				1.70		 5														
480				1.00		 3
480	 S40048TAC4M	 CWA	 464	 1.00	 190	 3	 4	 PC2	 2.32	 4.1	 55	240	 1.77	 3.74	1.91x2.91	 3.5	 14.0	 HPS400-3A	 10	
D
(1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP - 5 3/ ” Frame	
120 or				
3.90		
10				
277 or	S400TRIAC5M	 CWA	 467	 1.70	 200	 5	 3	PC2	 2.2	 4.1	 48	280	 2.05	 4.76	1.91x2.91	 3.9	 16.0	 HPS400-3A	 10	
E
347				1.35		 4				
120 or				
3.95		
10				
208 or
2.30	
	6	
200
1	PC3	 2.25	 4.1	 48	280	 2.05	 4.76	1.91x2.91	 3.9	 16.0	 HPS400-3A	 10	
D
	 S400MLTAC5M	 CWA	465	
240  or		 		2.00		 5				
277				1.70		 5
120 or				
4.00		
10
208 or	
	2.30		 6
	
	
240 or	 S400ML5AC5M	 CWA	 468	 2.00	
200	
5	
2	 PC3	 2.5	
4.5	 48	 300	 2.05	 4.76	 1.91x2.91	 3.9	
17.5	 HPS400-3A	 10	
D
277 or				
1.75		
5
480				1.00		 3
480	
S40048TAC5M	 CWA	 467	 1.00	 200	 3	 4	 PC3	 2.25	 4.1	 48	280	 2.05	 4.76	1.91x2.91	 3.9	 16.0	 HPS400-3A	 10	
D
(1) 430 WATT SON AGRO HIGH PRESSURE SODIUM LAMP 	
120 or				
4.50		
10															
208 or
2.50	
	8	
205
1	PC2	 2.25	 4.25	 48	330	 2.0	 4.7	 1.91x2.91	 3.9	 11.0	 HPS400-3A	 10	
D
	 S430MLTAC4M	 CWA	490	
240  or		 		2.10		 7															
277				1.80		 5	
4

4

3

Capacitors are available as an option for high power
factor operation.

See pages 4-31 and 4-32 for
Reference Drawings and Wiring Diagrams.

HID
CORE & COIL

PAGE 4-29

HPS
600-1000
WATTS

HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUM

• 6 0 Hz
• Minimum Starting Temperature: -40° C
• C
 WA models available

					
Nom				 Dimensions				
Capacitor				
Ignitor
				Max	Open												 Total		 Max	 UL
Input	Catalog*	
Circuit	 Watts	 Input	 Circuit	 Fuse	 Wir	 Ref				 Min	 Dry Film		
Oil Filled		
Weight	 Catalog	 Distance	 Bench
Volts	
Number	
Type	 Input	Current	Voltage	Rating	Dia	Dwg	 A	
B	 µF	 Volt	 Dia	
Ht	 Oval	
Ht	 (lbs.)	 Number	 to lamp (ft)	 Top Rise
(1) 600 WATT S106 HIGH PRESSURE SODIUM LAMP 			
120 or
			5.10		 20	
	
208 or	
	
	
3.10	
	15
CWA 640	
240
	 1	PC3	 3.0	 5.0	 55	300	 1.8	 4.7	 1.91x2.91	 3.9	 21.0	 HPS600-1B	 10	
A
S600MLTAC5M
240 or				
2.70		
10
277				2.35		 10
(1) 1000 WATT S52 HIGH PRESSURE SODIUM LAMP			
120 or	
	9.50	
	24	
	
S100024TAC5M	 CWA	1100
440
14	PC3	 3.8	 5.7	 26	 525	 n/a	 n/a	 1.91x2.91	 4.25	 26.0	 HPS1000-4B	 15	
C
240				4.80		 12
120 or				 9.60		 20				
277 or	 S1000TRIAC5M	 CWA	1100	 4.30	 440	 10	 3	PC3	 3.8	 5.75	 26	525	 n/a	 n/a	 1.91x2.91	 4.25	 27.0	 HPS1000-4B	15	 D
347				 3.40		 10							
120 or				 9.50		 24				
208 or	 S1000MLTAC5M	 CWA	1100	5.50	 440	15	1	PC3	 3.8	 5.7	 26	525	 n/a	 n/a	 1.91x2.91	 4.25	 26.0	 HPS1000-4B	15	 C
240 or				 4.80		 12				
277				 4.20		 10				
120 or				
9.45		
20														
208 or		
5.45	
	 15						 								
	
	
S1000ML5AC5M
240 or	
	 CWA	1048	 4.75	 440	 10	 2	PC3	 3.75	 5.65	 26	525	 n/a	 n/a	 1.91x2.91	 4.25	 26.0	 HPS1000-4B	 15	
D
277 or				
4.10		
10														
480				2.35		 8	
480	 S1000480AC5M	 CWA	1100	 2.45	 440	 8	 4	PC3	 3.8	 5.7	 26	525	 n/a	 n/a	 1.91x2.91	 4.25	 25.0	 HPS1000-4B	 15	
D
480	 S100048TAC5M	 CWA	1100	 2.45	 440	 8	 4	PC3	 3.8	 5.7	 26	525	 n/a	 n/a	 1.91x2.91	 4.25	 25.0	 HPS1000-4B	15	 D

HID
CORE & COIL

See pages 4-31 and 4-32 for
Reference Drawings and Wiring Diagrams.

PAGE 4-30

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HPS

HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUM
DESCRIPTION	

SUFFIX *

For Ballast Only	
For Bracket Only (see pg. 5-7)	
For Capacitor Only (see pg. 5-5, 5-6)	
For Distributor Replacement Kit
(see pg. 5-13 thru 5-15)	
For Canadian Distributor
Replacement Kit (see pg. 5-16)	
For Dry-Capacitor & Ballast
(see pg. 5-6)	
For Bracket & Capacitor
(see pg. 5-5, 5-7)	
For Bracket & Dry-Capacitor
(see pg. 5-6, 5-7)	

000
200
500

Bracket

W

500K

M
L

502K

	BRef. Dwg.	
	 1, 1a, 5	
	 PC1, 4	
	 PC2, PC3	

518
700

L	
W	
M	
S
4.00”	 0.75”	 3.35”	 0.25”
5.25”	 1.25”	 4.60”	 0.25”
7.75”	 1.25”	 5.75”	 0.25”

See p. 5-7 for adjustable mounting brackets and detailed bracket drawings.

718

REFERENCE DRAWING 1
2.625"
0.438"
A

.203" Dia Thru
4 Holes

S

B

A

2.188"

B

REFERENCE DRAWING 5

0.438"
.199" Dia Thru
4 Holes
.250" Dia Thru
2 Holes

0.594"

0.594"

0.438"

0.438"

A

0.437"

B

A

.250" Dia Thru
2 Holes

1.750"
2.188"

2.437"

1.750"
2.188"

2.188"

2.812"

1.218"

2.625"

REFERENCE DRAWING PC1

REFERENCE DRAWING PC2

A

B

2.812˝

.250" Dia Thru
2 Holes Cleared
2 Holes
for #10 Thru-Bolts

2.438˝

3.875"
4.250"

1.937"

0.637"
.250" Dia Thru
B
4 Holes
MAX

A

MAX

3.500˝ 3.938˝

B
4.250˝

4.375˝ 4.750˝

.250"
8

B
.250" Dia Thru
2 Holes

2 Holes Cleared
for #10 Thru-Bolts

3.875"
4.250"

4.375"

A

A

.250" Dia Thru
2 Holes

Four 0.250"
Male Quick
Connect
Terminals

3.875˝

4.250˝

1.937"

4.750"

4.750"

3.875˝
4.375"

4.375˝
5.375˝ 5.750˝

3.875"
4.250" 1.937"

5.375"
5.750"

Reference Drawing
7

0.625"
.250" Dia Thru
8 Holes

0.687"

A

.218" Dia Thru
4 Holes

B

A

B
1.062"

.250" Dia Thru
2 Holes

HID
CORE & COIL

Reference Drawing
6

Reference
Drawing
Note: Nominal
dimensions
provided above
5 for drawings and/or tolerances
Contact Universal

0.625"
.250" Dia Thru
8 Holes

8 Holes Cleared
for #10 Thru-Bolts

0.637"
B
.250" Dia Thru
8 HolesMAX

A

A

2 Holes Cleared
for #10 Thru-Bolts

3.875"

REFERENCE DRAWING PC3

4 Holes Cleared
for #10 Thru-Bolts

.250" Dia Thru
2 Holes

4.250" 1.937"

4.375"

Reference Drawing
3

Reference Drawing
2

4 Holes Cleared
for #10 Thru-Bolts

0.625"
B

Four 0.250" Male
Quick Connect
Blade Terminals

2.437"
1.218"

2.812"

.199" Dia Thru
4 Holes

Reference Drawing
1-A

.250" Dia Thru
4 Holes

3.500"
3.938"

.203" Dia Thru
4 Holes

Reference Drawing
1

B
0.812"

3.937"
3.500"

A

B

Ref

.250
4

.250" Dia Thru
2 Holes

.250" Dia Thru
2 Holes

3.437"
3.875"
2.750"

3.875"
4.250" 1.937"

4.375"
5.375"

3.437"

4.250"
3.437"
4.125"

3.875"

1.937"

4.375"

4.250" 1.937"

5.375"
5.750"

5.750"

Reference Drawing
13

Reference Drawing
14

PAGE 4-31

Refe

Reference Drawing
15

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID CORE & COIL BALLASTS

HPS

HIGH PRESSURE SODIUM

WIRING DIAGRAMS

Wiring Diagram 7

Wiring Diagram 11

Wiring Diagram 2

Wiring Diagram 8

Wiring Diagram 12

Wiring Diagram 3

Wiring Diagram 9

Wiring Diagram 13

Wiring Diagram 4

Wiring Diagram 10

Wiring Diagram 14

HID
CORE & COIL

Wiring Diagram 1

PAGE 4-32

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID CORE & COIL BALLASTS
50 HERTZ

• 50 Hz
• Minimum Starting Temperature: -40° C
• CWA, Normal and High Power factor models available

MH & HPS
50 HZ

					
Nom 				 Dimensions				
Capacitor					
Ignitor	 	
UL
					
Max	 Open												
Total		
Max	 Bench
Input	Catalog*	
Circuit	
Input	
Input	 Circuit	
Fuse	
Wir	 Ref				 Min	
Dry Film		
Oil Filled		
Wt.	 Catalog	 Dist. 	 Top
Volts	
Number	
Type	 Watts	 Curr.	Volt.	 Rating	 Dia	Dwg	 A	 B	 µF	Volt	 Dia	 Ht	 Oval	
Ht	 (lbs.)	Number	 lamp	 Rise
(1) 175 WATT M57 METAL HALIDE LAMP			
230	 M175230AC3M	 CWA	
205	 1.00	 310	
3	
15	 PC1	 2.25	3.55	 12	 400	 6.5	 3.82	 1.5	
3.13	 6.7	 n/a	 n/a	 C
(1) 250 WATT M58 METAL HALIDE LAMP			
230	 M250230AC3M	 CWA	
282	 1.40	 285	
4	
15	PC1	 3.0	4.3	 18	400	 n/a	 n/a	 2.01x3.01	 3.1	 9	 n/a	 n/a	 D
(1) 400 WATT M59 METAL HALIDE LAMP			
230	 M400230AC4M	 CWA	
448	 2.20	 300	
6	
15	 PC2	 2.13	3.75	 28	 425	 n/a	 n/a	 1.91x2.91	 3.9	 13	 n/a	 n/a	 D
(1) 1000 WATT M47 METAL HALIDE LAMP			
230	
M1000230AC5M	 CWA	
1080	
4.70	 420	
13	
18	 PC3	 3.4	 5.3	 30	 440	 n/a	
n/a	 2.01x3.01	
3.9	
21	
n/a	
n/a	
C
220				
8.50		
	 22												
A
18	 PC3	 3.45	4.90	 30	 440	 n/a	 n/a	 1.91x2.91	3.87	24	 n/a	 n/a	
M1000230DAC5M	CWA	 1080
405
B
230	
	4.80	 	13	
(1) 1500 WATT M48 METAL HALIDE LAMP			
220				
7.20		
	 20				
230	 M1500230AC5M	 CWA	
1605	
7.29	 430	
20	
18	 PC3	 4.38	 6.18	42(2x21)	480	 n/a	 n/a	1.97x3.66	 3.9	 30	 n/a	 n/a	 C
240				
6.80	 	
20						
(1) 70 WATT S62 HIGH PRESSURE SODIUM LAMP 			
220				
0.95		
	
2				
230	
S70230LC3M	
HX-HPF	
88	
1.10	 120	 	
2	
18	 PC1	 1.9 3.2 10	 280
1.26
2.83
n/a 	
n/a	 5.7 HPS150-3A 3
A
240				
1.05		
	
2							
(1) 250 WATT S50 HIGH PRESSURE SODIUM LAMP 			
220				
1.33	 	
5				
230	
S250230AC4M	
CWA	
280	
1.24	 188
5	
18	 PC2	 1.78	 3.58	 40	 300	 n/a	
n/a	 2.01x3.01	
3.9	 10.3	 HPS400-3A	 3	
B
240				
1.15	 	
5							
(1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP (continued)			
220				
2.00		
	
8				
230 	
S400230AC4M	
CWA	
465	
2.05	 190	
8	
18	 PC2	 2.5	 4.3	 64	 300	 n/a	
n/a	 1.91x2.91	
3.1	 15.5	 HPS400-3A	 3	
D
240				
2.10	 	
	
8							
(1) 1000 WATT S52 HIGH PRESSURE SODIUM LAMP 			
220				
5.10		
	 15				
230 	
S1000230AC5M	
CWA	
1100	
4.90	 445	
15	
15	 PC3	 4.0	 5.8	 36	 525	 n/a	
n/a	 1.96x3.65	
4.25	 27	 HPS1000-4B	 10	
D
240				
4.80		
	 15							

See page 4-34 for Reference Drawings and
Wiring Diagrams.

HID
CORE & COIL

PAGE 4-33

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

50 HZ

HID CORE & COIL BALLASTS
50 HERTZ

DESCRIPTION	

REFERENCE DRAWING PC1

SUFFIX *

For Ballast Only	
For Capacitor Only (see pg. 5-5, 5-6)	

000
500

0.250 Dia Thru
2 Holes

3.500˝ 3.938˝

4.250˝

3.875˝

4.375˝
5.375˝ 5.750˝

S

M
L

	BRef. Dwg.	
	
1	
	 2, 3, 4	
	 PC1	
	 PC2	
	 PC3	

A
B
MAX

2.812˝

2.438˝

Bracket

0.250 Dia Thru
8 Holes

0.199 Dia Thru
4 Holes
A
B
MAX

0.250 Dia Thru
2 Holes

W

REFERENCE DRAWING PC3

REFERENCE DRAWING PC2

L	
W	
M	
S
4.00”	0.75”	 3.60”	 0.25”
5.25”	 1.75”	 4.60”	 0.25”
5.25”	1.25”	 4.60”	 0.25”
7.75”	1.25”	 5.75”	 0.25”
7.75”	2.75”	 6.10”	 0.25”

4 Holes Cleared
for #10 Thru-Bolts
A
B
MAX

4.250˝

2 Holes Cleared
for #10 Thru-Bolts

See p. 5-8 for adjustable mounting brackets and detailed bracket drawings.

3.875˝

4.375˝ 4.750˝

S70230LC3M
70W

High Pressure Sodium

Specification Sheet
Input Volts

WIRING DIAGRAMS
220
230

Regulation
Line Volts
Lamp Watts

Wiring Diagram ±10%
15

Power Factor (min)
Input Watts
NOM. Open Circuit Voltage
Line Current (Amps)
Operating
Open Circuit
Starting

HID
CORE & COIL 50 HERTZ

olts Lamp Dropout Voltage (Line)

on UL Temperature Ratings
Volts
Insulation Class
p Watts Temperature Code

MIN. Starting Temperature
Wiring

ctor (min)
ts CAPACITOR Specifications
Microfarads
en CircuitVolts
Voltage
(min.)

220

240

±5%

±5%

±5%

±5%

±10%

±10%

±10%

90%
88 W

90%
88 W

90%
88 W

90%
88 W

90%
88 W

120 V

120 V

120 V

120 V

120 V

0.60
0.95

0.50
1.10

0.40
1.05

0.37

0.35

0.34

2

2

2

Specification Sheet

Recommended Fuse (Amps)

50Hz HX-HPF

±10%

±5%

135 V 230 135 V

240135 V

0

0

V

V

±10%H (180°C)±10%
±10% H (180°C)
H (180°C)
H (180°C) ±10%
±10%
±10% ±10%
A
- ±10%
-40°F -40°C -40°F -40°C
-40°F
Diagram
17-40°C
90%
90%
90%

1605 W
430 V

ent (Amps)
50Hz Test Procedures
7.20
ating
Secondary Open Ckt Voltage (V)
n Circuit Secondary Current Shorted (A)2.70
6.50
ing
Input Operating Current (A)

Input
Open Circuit Current (A) 20
ended Fuse
(Amps)

1605 W

10 uf

10 uf

280 V

280 V

430 V

1605 W

10 uf

430 V

280 V

7.29 108 - 132 6.80
108 - 132

108 - 132

2.551.15 - 2.15 2.30
1.15 - 2.15
1.15 - 2.15
6.200.46 - 0.56 6.00
0.55 - 0.67

90%

10 uf

430 V

280 V

0.48 - 1.3620 0.50 - 1.43 20
0.53 - 1.50
0.20 - 0.28 0.21 - 0.30 0.23 - 0.42

90%

COM (YEL)

-

-

0 -

0-

7.65 - 9.35 12-14
7.65 - 9.35
9.35
12-14 7.65 -12-14
12-147.65 - 9.35

Cu / Cu

-

7.6512-14
- 9.35
Cu / Cu

-

1

2

COM (YEL)

Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances
A

230 V (BLK)

10 uf

108 - 132

3
STARTER

Wiring Diagram 18

280 V

1.15 - 2.15

LAMP
(RED/BLK)
3

Wiring Diagram

430 V

108 - 132

CAP
(YEL)

Metal Halide
50Hz CWA

1605 W

Input Short Circuit Current (A)
V
150 V
150 V
V
150 V
60Hz Test Procedures
108 - 132
108 - 132
108 - 132
108 - 132
108 - 132
Secondary Open Ckt Voltage (V)
erature Ratings
1.40 - 2.10 1.40 - 2.10 1.40 - 2.10 1.40 - 2.10 1.40 - 2.10
Secondary Current Shorted (A)
H (180°C)
H (180°C)
H (180°C)
H (180°C)
H (180°C)
ation Class
0.04 - 0.13 0.05 - 0.14 0.05 - 0.15
None
C
perature Input
CodeOpen Circuit Current (A)None
0.16 - 0.31 0.16 - 0.31 0.16 - 0.31
Input Short Circuit Current (A)
-22°F -30°C -22°F -30°C -22°F -30°C -22°F -30°C -22°F -30°C
ting Temperature
High Potential
OR Specifications
2000 V
2000 V
2000 V
2000 V
2000 V
Test 1 Minute
2500
2500uf
V
V
uf V
uf V 42.0
uf2500 V 42.0 2500
42.0
42.0 uf 2500 42.0
ofarads Test 1 Second
480 V
480 V
480 V
480 V
480 V
(min.)
Core and Coil Specifications
1.90 in
1.90 in
1.90 in
1.90 in
1.90 in
Dimension A
t Procedures
3.20 in
3.20 in
3.20 in
3.20 in
3.20 in
Dimension B
400 - 4.555.70400
400 - 4.55
- 4.55
- 4.55
ndary Open
Ckt Voltage (V)
lbs 400
5.70 lbs 400 5.70
5.70 lbs
5.70
lbs
lbs - 4.55
Weight
/ Cu
Cu / Cu
Cu / Cu
Coil Material (Pri. / Sec.) 6.55 - 7.99Cu 6.37
- 7.77 6.19 - 7.55
Operating
Current (A)

M48

CAP
(RED)

230V (BLK)

±10%

1.15 - 2.15

0.36 - 0.44

1500W

H±10%
(180°C)

-40°F -40°C -40°F -40°C

1605 W

M1500230AC5M
Wiring Diagram 16

B
MAX

0.234 Dia Thru
4 Holes

CAP
( RED)

LAMP

(RED/BLK)

2.812"

0.250 Dia Thru
2 Holes

2.438"
COM ( YEL)

pout Voltage (Line)

ndary Current
Shorted
(A)
Lead Lengths
(inches)

S62

COM ( YEL)
3.500"

3.938"
Wiring
Diagram

Reference Drawing
Capacitor: R17058517
Height:

B
100 °C MAX
2.83 in

Width / Diameter:

1.26 in 4-34
PAGE

Max Case Temp:

0.250 Dia Thru
2 Holes

0.250 Dia Thru
8 Holes

A
Ignitor: HPS150-3A

Max Case Temp

105 °C

BTL:

3 ft
4.250"
No. 1 (Red or Blue)
No. 2 (Yellow)
No. 3 (Brown)

F-CAN BALLASTS
METAL HALIDE

MH
35-400

• 60 Hz
•M
 inimum Starting Temperature: -30° C
•C
 WA and High Power Factor Designs

WATT

This ballast may also be used with (1) 70 watt S88
	 High Pressure Sodium lamp.

7

M98 Designates Venture Lighting catalog numbers
	 MH70/4/MED, C/4/MED or MS70/C/84/MED/W

22

See page 4-40 for Reference Drawings and
Wiring Diagrams.

This ballast can be used with a MH200 ignitor to operate
		(1) 250 watt M103 lamp. Consult Universal for instructions.

8c

23

Two of these ballasts are required to operate the lamp.
Electrical data is for two ballasts, except for “Sound Rating,”
which is for each ballast

* Refer to Page 5-5.

PAGE 4-35

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID
CORE & COIL 50 HERTZ

						
Nom			
Dimensions			 Max
					
Max	 Open							
Dist		 Certifications
Input	
Catalog	
Circuit	Input	 Input	 Circuit	 Fuse	 Wir	Overall	 Case	 Mtg	 Total	 To	 Sound
Volts	
Number	
Type	 Watts	Current	Voltage	Rating	 Dia	 Length	 Length	Dim	 Weight	Lamp (ft)	Rating	 UL	 CSA
(1) 35/39 WATT M130 METAL HALIDE (with built-in ignitor)
120 	
1120-251A-TC	
CWA	 55	
0.50	
225	
2	
21	 9.50	
8.35	 8.85	 3.0	
20	
B	 Yes	 Yes
(1) 50 WATT M110 METAL HALIDE (with built-in ignitor)
120 	
	0.64	 	3	
or 11210-236C-TC	 HX-HPF	70
240
20	 11.75	 10.56	11.14	 11.0	 20	 B	 Yes	 Yes
277				
0.28	
	
2	
(1) 70 WATT M85 METAL HALIDE (with built-in ignitor)
120 	
	
	2.00	 	6	
or 11210-277C-TC7	HX-HPF 98
250
20	 11.75	 10.56	11.14	 11.0	 20	 B	 Yes	 Yes
277				
0.90	
	
3									
(1) 70 WATT M98 METAL HALIDE (with built-in ignitor)
120 	
	2.00	 	6	
or 11210-506C-TC22	 HX-HPF	90
250
20	 11.75	 10.56	11.14	 11.0	 20	 B	 Yes	 Yes
277				
0.90	
	
3								
120 	
	
	2.00	 	6	
or 11210-554C-TC	HX-HPF 90
250
20	 11.75	 10.56	11.14	 11.0	 20	 B	 No	 Yes
347				0.80		 3									
(1) 100 WATT M90 METAL HALIDE (with built-in ignitor)
120 	
	
	2.20	 	8	
or 11210-239C-TC	HX-HPF 125
250
20	 11.75	 10.56	11.14	 11.0	 20	 B	 Yes	 Yes
277				1.00		 4									
120 	
	
	2.20	 	8	
or 11210-606C-TC	HX-HPF 125
250
20	 11.75	 10.56	11.14	 11.0	 20	 B	 No	 Yes
347				0.70		 2									
(1) 150 WATT M81 METAL HALIDE (with built-in ignitor)
120 	
	
	3.70	 	10	
or 11210-242C-TC	HX-HPF 185
260
20	 14.31	 13.19	13.75	 14.0	 20	 B	 Yes	 Yes
277				1.60		 5									
(1) 150 WATT M102 METAL HALIDE (with built-in ignitor)
120 	
	
	3.70	 	10	
or 11210-539C-TC	HX-HPF 185
260
20	 14.31	 13.19	13.75	 14.0	 20	 B	 Yes	 Yes
277 				
1.60		
4			
						
(1) 175 WATT M57 METAL HALIDE LAMP
120
2.00
5
or	
20	 14.32	 13.19	13.75	 14.0	 *	 B	 Yes	 Yes
	300	 	
1110-245SC-TC 	 CWA	202	
			0.85		 3				
277	
120
1.75	
5
or	
20	 11.75	 10.55	11.10	 14.0	 *	 B	 Yes	 Yes
300	
	
1110-564C-TC 	 CWA	205	
			0.62		 2				
347	
(1) 250 WATT M58 METAL HALIDE LAMP
120
2.50	
8
or	
20	 16.75	 15.57	16.13	 18.0	 *	 C	 Yes	 Yes
280	
	
1110-246C-TC 8c	 CWA	295	
			1.10		 4				
277	
120
2.50	
8
or	
300	
	 22	 11.75	 10.55	11.10	 11.0	 *	 B	 Yes	 Yes
1111-246C-TC 23	 CWA	300	
			1.10		 4				
277	
120
2.50	
8
or	
20	 16.65	 15.55	16.10	 17.5	 *	 C	 Yes	 Yes
285	
	
1110-566C-TC 	 CWA	295	
			0.95		 3				
347	
(1) 400 WATT M59 METAL HALIDE LAMP
120
4.00	
10
or	
20	 19.25	 18.06	18.63	 22.0	 *	 C	 Yes	 Yes
300	
	
1110-247SC-TC	 CWA	463	
			1.75		 5				
277	
120
4.00	
10
or	 1111-247SC-TC 23	 CWA	460	
300	
	 22	 14.31	 13.19	13.75	 14.0	 *	 B	 Yes	 Yes
277		 		1.75		 5				
120
4.30	
10
or	
20	 19.25	 18.05	18.60	 22.0	 *	 C	 Yes	 Yes
300	
	
1110-568C-TC 	 CWA	460	
			1.50		 4
347	

HPS
35-250
WATT

F-CAN BALLASTS
HIGH PRESSUE SODIUM

• 60 Hz
• Minimum Starting Temperature: -40° C
• CWA and High Power Factor Designs

						
Nom			
Dimensions			 Max
					
Max	 Open							
Dist		 Certifications
Input	
Catalog	
Circuit	Input	 Input	 Circuit	 Fuse	 Wir	Overall	 Case	 Mtg	 Total	 To	 Sound
Volts	
Number	
Type	 Watts	Current	Voltage	Rating	 Dia	 Length	 Length	Dim	 Weight	Lamp (ft)	Rating	 UL	 CSA
(1) 35 WATT S76 HIGH PRESSURE SODIUM (with built-in starter)
120
0.80	
5
or	 12210-261C-TC	 HX-HPF	55	
20	 11.75	10.55	 11.10	 9.0	 10	 B	 Yes	 Yes
120	
	
			0.35		 2
277	
(1) 50 WATT S68 HIGH PRESSURE SODIUM (with built-in starter)
120
1.05	
3
or	 12210-236C-TC	 HX-HPF	71	
20	 11.75	10.55	 11.10	 9.0	 10	 B	 Yes	 Yes
125	
	
			0.45		 2
277	
(1) 70 WATT S62 HIGH PRESSURE SODIUM (with built-in starter)
120
1.60	
5
or	 12210-237C-TC	 HX-HPF	97	
20	 11.75	10.56	 11.14	 9.15	 10	 B	 Yes	 Yes
140	
	
			0.70		 2
277	
120
1.69	
5
or	 12210-552C-TC 	 HX-HPF	109	
20	 11.75	10.55	 11.10	 9.2	 10	 B	 Yes	 Yes
145	
	
			0.63		 2
347	
(1) 100 WATT S54 HIGH PRESSURE SODIUM (with built-in starter)
120
2.00	
5
or	 12210-239C-TC	 HX-HPF	125	
20	 11.75	10.55	 11.10	 10.4	 10	 B	 Yes	 Yes
130	
	
			0.90		 3
277	
120
2.10	
6
or	 12210-606C-TC 	 HX-HPF	126	
20	 11.75	10.55	 11.10	 10.4	 10	 B	 Yes	 Yes
165	
	
			0.90		 3
347	
(1) 150 WATT S55 HIGH PRESSURE SODIUM (with built-in starter)
120
2.80	
8
or	 12210-241C-TC	 HX-HPF	185	
20	 14.30	13.15	 13.75	 14.0	 10	 B	 Yes	 Yes
120	
	
			1.20		 4
277	
120
2.80	
8
or	 12210-602C-TC 	 HX-HPF	185	
20	 14.30	13.15	 13.75	 14.1	 10	 B	 Yes	 Yes
120	
	
			1.03		 3
347	

HID
F-CAN

See page 4-40 for Reference Drawings and
Wiring Diagrams.

PAGE 4-36

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

34

35

White

Line

Insulate Unused Input
Lead for 300 Volts.

B
A
L
L
A
S
T

277V or 347V Black

BALLAST

or 120V
Black/Yellow
Red

Black

White

Wiring Diagram
B
34
A
L
L
A
S
T

F-CAN

0.250" Dia.

1.000"
2.000"

Red

Red

White

4.000"
4.500"
277V

White or
Yellow

Wiring Diagram
34

B
A
L
L
A
S
T

Wiring Diagram
35

Wiring Diagram
36

277V Black

or 120V Black/Yellow

Separately Insulate Unused Input
Lead for 300 Volts

HID CORE & COIL BALLASTS

Line
Insulate Unused Input
Lead for 300 Volts.

White
White or
Yellow

Black

Red

F-CAN

Wiring Diagram
36

Black or
Yellow

0.406"

or 120V
Black/Yellow
0.562"
0.250" Dia.

Separately Insulate Unused Input
1.000"
2.000"
Lead for 300
Volts

Wiring Diagram
35

Wiring
Diagram
Mounting
Bracket Assemblies
4.500"
0.406"

4.000"

36

F-CAN BALLASTS OPTIONAL ACCESSORIES
Mounting Bracket Assemblies

0.562"

Splice Box

Mounting Bracket Assemblies
Tee-Pee Lead
Wire Covers
1.437"

1.500"
2.000"
2.562"

0.250" Dia.

1.750"
0.218" Dia.

1.000"
2.000"

2.531"
1.437"

0.406"

4.000"
4.500"

Tee-Pee Lead Wire Covers
1.500"
2.000"
2.562"

0.562"

Embossed Dimples
2 Places
2.000"
3.000"

1.750"

2.812"

0.850" Dia.
Knockouts
5 Places

0.218" Dia.

Catalog Number
2-BMB-1.
Mounting Bracket Assemblies

Catalog NumberTee-Pee
TP5. Ref.part
Lead#001-2013.
Wire Covers

Available for the remote installation of ballasts. Each
assembly consists of two (2) mounting brackets, four (4)
screws, four (4) washers and four (4) nuts.

For use where ballast is attached to the surface of an
enclosure or raceway.

Embossed Dimples
2 Places

1.437"

1.500"
2.000"
2.562"

2.531"

0.297" Dia.
Mounting Holes
2 Places

Catalog Number SB-4. Splice
Ref. part Box
#001-2009
2.000"
3.000"

2.812"

0.850" Dia.
Knockouts
5 Places

For use with all F-Can Ballasts. It is easily installed on
0.297"F-Can
Dia. ballast. It
the anchor bracket provided on each
Mounting Holes
contains five (5) 7/8” diameter knockouts.
2 Places
Splice Box

1.750"
0.218" Dia.

2.531"

REFERENCE
Tee-Pee DRAWING
Lead Wire Covers
FOR F-CAN

se

Ca

2.000"
3.000"

2.812"

0.850" Dia.
Knockouts
5 Places

0.297" Dia.
Mounting Holes
2 Places

th

ng

Le

Embossed Dimples
2 Places

Height

Width

Splice Box

th
ng
ng
ti
Le
un
l
Mo
al
r
e
Ov

Hole

Mounting
Width

WIRING DIAGRAMS
B
A
Wiring Diagram 20 L
L
A
S
T
Black

L
L
A
S
T

Red

White
White or
Yellow

Wiring Diagram
35

Red

Red

120V Black

277V Black

Wiring Diagram 22

Black or
Yellow

HID
F-CAN

Line

am

B
A
L
L
A
S
T

White

LLAST

B

A
Wiring Diagram
21

Red

or 120V Black/Yellow

Separately
Insulate
Unused Input
Neutral to Lamp
Shell
Lead for 300 Volts

Wiring Diagram
36

Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances

ia.
1.000"
2.000"

00"

0.406"

0.562"

PAGE 4-37

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

IGNITORS

STANDARD IGNITORS • INSTANT RESTRIKE IGNITORS • LONG
DISTANCE IGNITORS • AUTOMATIC SHUTOFF
IGNITORS • SHUTOFF DEVICES

Catalog Number	

Description	

Reference Drawing Number

--STANDARD IGNITORS										 (See pg. 5-43)
PULSE START METAL HALIDE

MH 70-3B 13	
MH 100-3A	
MH 150-1A	
MH 200-1B 13	
MH 350-1A	

P 750-1B13	
HPS 1000-4B13	
HIGH PRESSURE SODIUM

HPS 150-3A	
HPS 400-3A	
HPS 450-1B 13	
HPS 460-1B 13	
HPS 600-1B	
HPS 1000-4B 13	
HPS 1000-6B 13	

For double-ended MH lamps with HX-HPF ballasts: 70 watt (M85), 100 watt (M91), and 150 watt (M81)	
29	
For MH lamps with HX-HPF ballasts: 35/39w(M130), 50w(M110), 70w(M98), 100w(M90/M140), and 150w(M102/M142)	 25
For 150 watt (M102/M142) lamp with CWA ballast	
26
For double-ended MH 250 watt (M80) lamp	
27a
For MH lamps with CWA ballasts: 175 watt (M152/M137), 200 watt (M136), 250 watt (M153/M138),
320 watt (M154/M132), 350 watt (M131), 400 watt (M155/M135), and 450 watt (M144)	
26
For 750 watt (M149) MH lamp	
29
For MH lamps: 875 watt (M166) and 1000 watt (M141). It is also used for 1000W HPS lamps	
29
For HPS lamps of 150 watt or less with HX-HPF ballast, except 150 watt S56 lamp	
26
For HPS lamps from 200 to 400 watts and 150 watt S56 lamp with CWA ballasts	
26
For 150 watt S56, 200, 250 or 400 watt lamps with 240 volt/60 Hz reactor ballasts. With attached mounting bracket.	
27
For 200, 250 and 400 watt lamps with HX-HPF ballasts and 50 Hz reactor ballasts. With attached mounting bracket.	
27
For 600 watt lamps.	
27
For 1000 watt HPS and Pulse Start Metal Halide lamps. With attached mounting bracket.	
29
Obsolete	29

PLUG REPLACEABLE IGNITORS
PULSE START METAL HALIDE

MH 150-G15	
	
HIGH PRESSURE SODIUM

HPS 150-G01	
HPS 400-G05	

For MH lamps with HX-HPF ballasts: 35/39 watt (M130), 50 watt (M110), 70 watt (M98), 100 watt (M90/M140), 			
and 150 watt (M102/M142)	
32
For HPS lamps of 150 watt or less with HX-HPF ballast, except 150 watt S56 lamp	
For HPS lamps from 200 to 400 watts and 150 watt S56 lamp with CWA ballasts	

32
32

INSTANT RESTRIKE IGNITORS
HIGH PRESSURE SODIUM

HPS 150-5B 13	

Instant Restrike Ignitor — for lamps of 150 watts or less except 150 watt S56. Ignitor has attached mounting bracket.	

30

LONG DISTANCE IGNITORS
PULSE START METAL HALIDE

MH 100-5A	
MH 100-5A	
MH UNV-5B	

HIGH PRESSURE SODIUM

HPS 150-4A	
HPS 400-4A	

For MH lamps from 35 to 50 watts. Max Ballast to Lamp Distance ( ~ 20’)	25
For MH lamps from 70 to 150 watts. Max Ballast to Lamp Distance ( ~ 30’)	25
For MH lamps from 35 to 450 watts. Ignitor incorporates automatic resetting thermal protection.
Max Ballast to Lamp Distance ( ~ 50’)	33
For HPS lamps of 150 watt or less, excerpt 150 watt S56 lamp. Max Ballast to Lamp Distance ( ~ 20’)	24
For HPS lamps from 200 to 400 watts and 150 watt S56 lamp. Max Ballast to Lamp Distance ( ~ 25’)	33

AUTOMATIC SHUTOFF IGNITORS
PULSE START METAL HALIDE

	

HID
F-CAN

	

MH 100-35B 13	
MH 150-35B 13	
MH 350-15B 13	
P 750-15B 13	

HIGH PRESSURE SODIUM

	

HPS 150-45B 13	
HPS 400-45B 13	

For MH lamps: 35/39 watt (M130), 50 watt (M110), 70 watt (M98), 100 watt (M90/M140), and 150 watt (M102/M142).
With attached mounting bracket	
For 150 watt M81 lamp with CWA ballasts. With attached mounting bracket.	
For MH lamps: 175 watt (M152/M137), 200 watt (M136), 250 watt (M153/M138), 320 watt (M154/M132),
350 watt (M131), 400 watt (M155/M135), and 450 watt (M144)	
For 750 watt (M149) MH lamp	

27
31
31
31

For lamps of 150 watts or less except 150 watt S56. With attached mounting bracket.	
27
For lamps from 200 to 400 watts and 150 watt S56 with constant wattage autotransformer ballasts.	27
With attached mounting bracket.

AUTOMATIC SHUTOFF DEVICES

In addition to one-piece shutoff ignitors, automatic shutoff devices are available as separate components for use with the ignitors below.

SA-100	
	

13	

HPS 150-3A, HPS 150-5B, HPS400-4A, HPS460-1B, MH100-5A, MH70-3B, MH100-3A, MH150-1A	
	
MH350-1A, HPS150-4A, HPS400-3A, HPS600-1B, MHUNV-5B, MH200-1B

33a

May also be available without attached mounting bracket. Substitute “A” suffix for “B” suffix when ordering. Minimum quantities may apply.

PAGE 4-38

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

IGNITORS

Lamp	 ANSI	
Circuit	
Watts	Code	 Type	

Standard	
Ignitors	

Auto	
Shutoff	

Instant	
Restrike	

Long Distance
Ignitors

Lamp	
ANSI	
Circuit	
Standard	
Watts	Code	Type	 Ignitors	

HPS 150-45B	
HPS 150-45B	
HPS 150-45B	
HPS 150-45B	
HPS 150-45B	
HPS 400-45B	
HPS 400-45B	
HPS 400-45B	
HPS 400-45B	
HPS 400-45B	
HPS 400-45B	
HPS 400-45B	
—	
—	

HPS 150-5B	
HPS 150-5B	
HPS 150-5B	
HPS 150-5B	
HPS 150-5B	
—	
—	
—	
—	
—	
—	
—	
—	
—	

HPS 150-4A
HPS 150-4A
HPS 150-4A
HPS 150-4A
HPS 150-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
—
—

35	
50	
70	
70	
100	
100	
100	
150	
150	
150	
350	

S76	
S68	
S62	
S54	
S55	
S56	
S50	
S50	
S50	
S51	
S51	
S51	
S106	
S52	

Reactor	
Reactor, HX	
Reactor, HX	
Reactor, HX	
Reactor, HX	
CWA	
Reactor	
CWA	
HX	
Reactor	
CWA	
HX	
CWA	
CWA	

Long Distance
Ignitors

—	
—	
MH 70-35B	
MH 100-35B	
MH 100-35B	
MH 100-35B	
—	
—	
MH 150-35B	
MH 100-35B	

MH 100-5A
MH 100-5A
MH 100-5A
MH 100-5A
MH 100-5A
MH 100-5A
—
—
—
MH 100-5A

METAL HALIDE IGNITORS

HIGH PRESSURE SODIUM IGNITORS

35	
50	
70	
100	
150	
150	
250	
250	
250	
400	
400	
400	
600	
1000	

Auto	
Shutoff	

HPS 150-3A	
HPS 150-3A	
HPS 150-3A	
HPS 150-3A	
HPS 150-3A	
HPS 400-3A	
HPS 450-1B	
HPS 400-3A	
HPS 460-1B	
HPS 450-1B	
HPS 400-3A	
HPS 460-1B	
HPS 600-1B	
HPS 1000-4B	

350	

M130	
M110	
M85	
M98	
M90	
M90	
M91	
M81	
M81	
M102	

M131	
M131	

Reactor	
HX	
HX	
HX	
Reactor	
CWA	
HX	
HX	
CWA	
HX	

Reactor	
HX	

MH 100-3A	
MH 100-3A	
MH 70-3B	
MH 100-3A	
MH 100-3A	
MH 100-3A	
MH 70-3B	
MH 70-3B	
MH 150-35B	
MH 100-3A	

MH 70-3B	
MH 70-3B	

—	
—	

—
—

STANDARD IGNITORS

LONG DISTANCE IGNITORS

Standard Ignitors are supplied with all Universal High
Pressure Sodium and Metal Halide ballasts requiring ignitors.
These ballasts are supplied with an appropriate external ignitor
unless the ignitor is permanently attached to or built into the
ballast.

Long Distance Ignitors are used in situations where a ignitor
must be mounted further from the lamp than is recommended
for a standard ignitor. The maximum lamp to ignitor distance for
these ignitors is 50 feet, which may vary depending on the type
of lamp, ballast, fixture, and wiring.

INSTANT RESTRIKE IGNITORS

AUTOMATIC SHUTOFF IGNITORS

An Instant Restrike Ignitor generates multiple pulses to restrike
a lamp arc after a brief power interruption has extinguished
it, without the typical 3-minute cool-down time. A Standard
Ignitor cannot restrike an arc until the lamp has had time to
sufficiently cool. Even though an Instant Restrike Ignitor can
reinitiate the lamp arc immediately upon restoration of power,
the lamp is still subject to warmup. The following chart is based
on an S55 lamp.

In the event of a lamp failure, a Standard Ignitor will continue
to pulse, trying to start the lamp. This may reduce the life of the
ignitor. An Automatic Shutoff Ignitor will apply pulses for 10 to
12 minutes and then deactivate if a lamp arc cannot be
initiated. Resetting the ignitor is accomplished by momentarily
interrupting the power to the ballast. For this reason, these ignitors are not recommended for use on unswitched circuits.

Restrike 	
Time	

	1 second	
	5 seconds	
	15 seconds	
	30 seconds	
	1 minute	
	Cold Start	

2 seconds	
Instant	
Instant	
Instant	
Instant	
Instant	

Light Output	
On Reignition	

87%	
83%	
76%	
62%	
46%	
36%	

AUTOMATIC SHUTOFF DEVICES

Lamp Warmup
Time

Automatic shutoff devices can be used with a standard ignitor
to convert standard ignitor into an automatic shutoff ignitor.
Simply use the automatic shutoff device with appropriate
standard ingnitor. Matching ignitors are listed in the table on
previous page. Automatic shutoff device coupled with standard
ignitor is equivalent to automatic shutoff ignitor. Wiring diagrams of SA-100 automatic shutoff device are shown on Ref.
Drawings 34a and 34b.

35 seconds
70 seconds
130 seconds
190 seconds
255 seconds
360 seconds

PLUG REPACEABLE IGNITORS
Incorporates terminals and a separate mounting base to
simplify construction and replacement.

TEMPERATURE RATING
Most ignitors are rated for a 105°C maximum case
temperature. Consult ballast specification sheets at
www.unvlt.com for specific details.
PAGE 4-39

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID
IGNITORS

Time Lamp Is	
Extinguished	

REFERENCE DRAWINGS

IGNITORS

All dimensions in decimals.
All lead lengths: 13 inches ±1

No. 1 (Red or Blue)

No. 1 (Red or Blue)

120V (Black/Yellow)

No. 1 (Red or Blue)

No. 2 (Yellow)

No. 2 (Yellow)

No. 2 (Yellow)

No. 2 (Yellow)

No. 3 (Brown)

No. 3 (Brown)

COM (Yellow)

No. 3 (Brown)

1.25"
2.00"

1.25"
2.50"

2.50"

Ref. Drawing 25

Ref. Drawing 24

1.25"

1.25"
2.25"

Ref. Drawing 25a

Ref. Drawing 26

120V (Black/Yellow)
No. 1 (Red or Blue)

Com. (Yellow)

No. 2 (Yellow)

Ballast (Blue/White)

No. 3 (Brown)

Lamp (Blue)

Mounting Bracket

Mounting Bracket

1.31"

1.31"

No. 1 (Red or Blue)

No. 1 (Red or Blue)

No. 2 (Yellow)

No. 2 (Yellow)

No. 3 (Brown)

No. 3 (Brown)

Mounting Bracket

Mounting Bracket

1.31"

1.31"

1.25"

1.25"

0.22"

3.50"
4.31"
4.75"

0.22"

Com. (Yellow)

Com. (Yellow)

Ballast (Blue/White)

Ballast (Blue/White)

Lamp (Blue)

Lamp (Blue)

Mounting Bracket

Mounting Bracket

1.56"

1.62"

0.88"

0.88"
3.50"
4.31"
4.75"

0.22"

Ref. Drawing 28

Ref. Drawing 27a

Ref. Drawing 27

2.05"

2.05"

0.88"

0.88"
3.50"
4.31"
4.75"

1.25"

1.25"
2.05"

2.05"

3.10"
4.31"
4.75"

0.22"

Ref. Drawing 29

1.56"

1.50"

2.60"

2.65"

0.88"

0.88"
3.50"
4.31"
4.75"

0.22"

Ref. Drawing 31

Ref. Drawing 32

HID
IGNITORS

Ref. Drawing 30

0.22"

3.75"
4.31"
4.75"

Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances

PAGE 4-40

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Notes

HID

PAGE 4-41

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

eHID
Less energy. Enhanced performances.
Experience significant energy savings and increased lumen output vs. halogen lamps with Electronic
High Intensity Discharge (HID) ballasts from Universal Lighting Technologies. Vossloh-Schwabe (VS), also
a Panasonic Lighting Company, recently merged its US operation into Universal. This merger combines
Vossloh’s market leading high quality electronic HID product line with Universal’s extensive offering.
There are numerous advantages of using VS electronic HID ballasts. Operating HID lamps used in HID
lighting systems with electronic ballasts greatly increases system efficiency in comparison with magnetic
ballasts. These ballasts are designed to provide optimal lamp performance
and maximum energy savings. With enhanced capabilities to downsize
the form factor of luminaire housings and reduce wiring costs, VS electronic HID ballasts lead the way to electronic solutions for HID lighting. Microprocessor controlled intelligence offers superior lamp performance and the
flexibility for proprietary value-added functions. VS electronic HID ballasts
cover your HID needs with products for Metal Halide Lamps ranging from
20 Watts to 150 Watts.
VS electronic HID ballasts continuously monitors lamp characteristics
during operation and adjusts the lamp current to optimize performance.
This guarantees controlled operation in all modes of operation. The lamp
color temperature is also stabilized by using VS electronic HID ballasts
due to its relatively constant output power characteristics in addition to
producing flicker free lighting that usually occurs at the end of the discharge lamp’s service life. The
technology enhancements of VS electronic HID ballasts, allowing very small form factors and light weight
designs, has enabled new, innovative luminaire designs.

ELECTRONIC HID

Universal Lighting Technologies is a member of the Panasonic Group

Product Overview
Micro Series: The introduction of the smallest eHID ballasts in the market was
coordinated with the launch of the new miniaturized capsule MH lamps
enabling the ultimate luminaire design flexibility. Extremely compact
and aesthetically pleasing, luminaire designs are approaching
the form factor and size of low voltage halogen systems.

Mini Ballast Series: Two ideal form factors that are used
in millions of HID track light luminaires characterize the mini series
of eHID ballasts. The mini-slim and mini-square units revolutionized
track lighting by allowing significantly smaller and greater
variety of luminaire designs while providing
energy savings of 60-70%
versus halogen systems.

ELECTRONIC HID

Standard Case “Valued-added Series”: Millions of recessed,
track-head and specialty luminaires have used the de facto industry
standard enclosure since introduction. The significant energy savings
and enhanced reliability of our ballasts promoted the rapid escalation
of electronically ballasted MH luminaires for almost 15 years. Technological advancements have now allowed the integration of multiple,
value-added functions such as: a powersource for the self-heating
thermal protectors, an electronic 277V step-down transformer, and
an intelligent auxiliary lighting control for back-up lighting during
lamp hot restrike modes. Ideal for new, retrofit and replacement
applications in recessed luminaires.
Features and Benefits:
• Optimum lamp performance
• Rugged, compact and lightweight design
• High power factor
• Enhanced color and CRI uniformity
• Shut-down protection
• Reduced wiring costs
• Eliminates nuisance lamp cycling at end-of-lamp life (intelligent lamp sensing capabilities)
• Constant lamp power
• Reduced lamp dropouts due to improved line voltage dip withstand
• Quiet operation
• Durable performance for various applications
• Fewer SKUs required in inventory
• Broadens design flexibility for new applications and luminaries

PAGE 5-2

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

eHID Product Family
Part #

Description

Lamp Wattage

Lamp Type

Input Voltage

Input Power

Mounting

Lead Exit

Dimensions

Wiring

Micro Series
188514

M2012CK-7EUN

20

M/C156

120

24.5

No Feet

Side

1

1

188882

M2012CK-7EUN-F

20

M/C156

120

24.5

Feet

Side

2

1

188883

M2012CK-7EUN-J

20

M/C156

120

24.5

Studs

Top

3

1

188574

M2212CK-7EUN

22

M/C175

120

26.5

No Feet

Side

1

1

188884

M2212CK-7EUN-F

22

M/C175

120

26.5

Feet

Side

2

1

188885

M2212CK-7EUN-J

22

M/C175

120

26.5

Studs

Top

3

1

188635

M3912CK-7EUN

39

M/C130

120

45

No Feet

Side

4

1

188776

M3912CK-7EUN-F

39

M/C130

120

45

Feet

Side

2

1

188756

M3912CK-7EUN-J

39

M/C130

120

45

Studs

Top

3

1

188757

MTm3912CK-7EUN

39Tm

M/C179

120

45

No Feet

Side

4

1

188777

MTm3912CK-7EUN-F

39Tm

M/C179

120

45

Feet

Side

2

1

188758

MTm3912CK-7EUN-J

39Tm

M/C179

120

45

Studs

Top

3

1

Mini-Slim Series
188246

M3912CK-6EUN-F

39

M/C130

120

45

Feet

Side

5

1

188164

M7012CK-6EUN-F

70

M/C98, M/C139, M/C143

120

77

Feet

Side

5

1

1

Mini-Square Series
188901

M2012-27CK-6EU-F

20

M/C156

120-277

24

Feet

Side

10

188902

M2012-27CK-6EU-J

20

M/C156

120-277

24

Studs

Top

9

1

1889031

M2012/27CK-6EU-JT3

20

M/C156

120/277

24/26

Studs

Top

9

2a,2b,2c

188895

M3912-27CK-6EU-F

39

M/C130

120-277

44

Feet

Side

10

1

188896

M3912-27CK-6EU-J

39

M/C130

120-277

44

Studs

Top

9

1

1888971

M3912/27CK-6EU-JT3

39

M/C130

120/277

44/46

Studs

Top

9

2a,2b,2c

188939

M7012-27CK-6EU-F

70

M/C98, M/C139, M/C143

120-277

77

Feet

Side

10

1

188940

M7012-27CK-6EU-J

70

M/C98, M/C139, M/C143

120-277

77

Studs

Top

9

1

1889411

M7012/27CK-6EU-JT3

70

M/C98, M/C139, M/C143

120/277

77/79

Studs

Top

9

2a,2b,2c

Standard Series
188610

M2012-27CK-5EU-F

20

M/C156

120-277

24

Feet

Side

12

1

1886111

M2012/27CK-5EU-JT3

20

M/C156

120/277

24/26

Studs

Top

13

2a, 2b, 2c

188156

M3912-27CK-5EU

39

M/C130

120-277

44

No Feet

Side

14

1

188157

M3912-27CK-5EU-F

39

M/C130

120-277

44

Feet

Side

12

1

188301

M3912-27CK-5EU-J

39

M/C130

120-277

44

Studs

Top

13

1

1886291

M3912/27CK-5EU-JT3

39

M/C130

120/277

44/46

Studs

Top

13

2a, 2b, 2c

1886302

M3912/27CK-5EU-JA3

39

M/C130

120/277

46/187

Studs

Top

13

3a, 3b, 3c

188612

M5012-27CK-5EU-F

50

M148 or M110

120-277

56

Feet

Side

12

1

1886131

M5012/27CK-5EU-JT3

50

M148 or M110

120/277

56/58

Studs

Top

13

2a, 2b, 2c

188165

M7012-27CK-5EU

70

M/C98, M/C139, M/C143

120-277

78

No Feet

Side

14

1

188166

M7012-27CK-5EU-F

70

M/C98, M/C139, M/C143

120-277

78

Feet

Side

12

1

188167

M7012-27CK-5EU-J

70

M/C98, M/C139, M/C143

120-277

78

Studs

Top

13

1

1886311

M7012/27CK-5EU-JT3

70

M/C98, M/C139, M/C143

120/277

79/81

Studs

Top

13

2a, 2b, 2c

1886321

M7012/27CK-5EU-JA3

70

M/C98, M/C139, M/C143

120/277

81/212

Studs

Top

13

3a, 3b, 3c

1886331

M10012/27CK-5EU-JT3

100

M/C90, M/C140 and M/C164

120/277

110/212

Studs

Top

13

2a, 2b, 2c

188168

M10012-27CK-5EU

100

M/C90, M/C140 and M/C164

120-277

110

No Feet

Side

14

1

188169

M10012-27CK-5EU-F

100

M/C90, M/C140 and M/C164

120-277

110

Feet

Side

12

1

188302

M10012-27CK-5EU-J

100

M/C90, M/C140 and M/C164

120-277

110

Studs

Top

13

1

1886341

M10012/27CK-5EU-JA3

100

M/C90, M/C140 and M/C164

120/277

112/235

Studs

Top

13

3a, 3b, 3c

188638.053

M15012-27CK-5EU-F

150

M/C102/E and M/C142/E

120-277

163

Feet

Side

16

1

188639.053

M15012-27CK-5EU-J

150

M/C102/E and M/C142/E

120-277

163

Studs

Top

15

1

M15012/27CK-5EU-JT3

150

M/C102 and M/C142

120/277

163/165

Studs

Top

15

2a, 2b, 2c

188989.051,3

Footnotes:
1 – “JT3” models have 120V power source for operating the heater on self-heating thermal protectors allowing dual-rated input voltage fixtures.
3 – Exceeds EISA 2007 90% minimum ballast efficiency requirement for 150W and higher HID lamp applications.

PAGE 5-3

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

ELECTRONIC HID

2 – “JA3” models have same 120V power source as JT3 models , but also have an integrated auxiliary light control which drives a quartz restrike back-up lamp.

Wiring Diagrams
1

N

WHITE

120V

RED

L

1

BLACK
BLUE
GREEN

120/277V with IDTP Tap
2b

WIRING (with 3-wire 120V IDTP)

WIRING (with 4-wire 120V IDTP)

RP-1B
IDTP 2
black

L

blue

N

WHITE

black

120/277

white

120/277

N

WHITE

PURPLE

blue
white

L

RP-5A
IDTP 2

red

2a

PURPLE

BLACK

BLACK

GREEN

GREEN

RED

RED

1

BLUE

1

BLUE

2c

WIRING (with 3-wire 277V IDTP)
RP-4A
IDTP 2

L
277

N

red
white

black

WHITE

PURPLE
BLACK
GREEN
RED

1

BLUE

120/277V with Auxiliary Control + IDTP Tap
Wiring & Dimensions Diagrams (shown in millimeters and inches)

3b

WIRING (with 3-wire 120V IDTP)

WIRING (with 4-wire 120V IDTP)

RP-1B
IDTP 2

N

WHITE

HALOGEN LAMP
<150W

L

blue
white

black

120/277

black

120/277

N

ORANGE
PURPLE

WHITE

BLACK

GREEN

GREEN

RED

RED

1

Connect red lead to center contact on Edison base lampholders

2

IDTP - Insulation Detector Thermal Protector

1

BLUE

Notes for Wiring Diagram
1

blue

ORANGE
PURPLE

BLACK

BLUE

ELECTRONIC HID

HALOGEN LAMP
<150W

red

L

RP-5A
IDTP 2

white

3a

3c

WIRING (with 3-wire 277V IDTP)
RP-4A
IDTP 2

L

black

277

N

WHITE

HALOGEN LAMP
<150W

red

white

ORANGE
PURPLE
BLACK
GREEN
RED

1

BLUE

PAGE 5-4

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Wiring
Dimming Ballasts
4a

4b

WIRING (For Fixed Output)

WIRING (For Dimming Control)

RED

RED

BLUE

BLUE

GREEN

GREEN

BLACK

BLACK
WHITE

WHITE
GREY (+)

GREY (+)

PURPLE (+)

PURPLE (+)

0 - 10VDC
DIMMER

Dimensions
1

2
33.5/1.32
29.7/1.17
33.0/1.30
97.7/3.85
76.0/2.99

Temp. Testpoint

31.0/1.22
28.0/1.10

Temp. Testpoint

104.7/4.12

3

4
33.5/1.32
16.7/0.66

33.5/1.35

96.7/3.81
90.7/3.57

Temp. Testpoint

38.1/1.5

Temp. Testpoint

11.8/0.47

8-32 stud
50.8/2.0

PAGE 5-5

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

ELECTRONIC HID

30.1/1.19

Dimensions
5

6

28.6/ 44.2/
1.13 1.74

28.6/ 44.2/
1.13 1.74

133/5.25

133/5.25

140..0/5.51

140.0/5.51
30.0/1.18

30.0/1.18

7

8
44.2/
1.74

64.8/2.55

75.6/2.98

22.1/
0.87
127.8/5.03
50.8/2

86.8/3.42

10.9/0.43

95.1/3.74

39.5/
1.56

Temp. Testpoint

9

30.6/1.21

10

76.2/3.0

64.8/2.55

75.6/2.98

38.1/1.5

86.8/3.42

89.4/3.52

95.1/3.74

50.8/2.0
11.8/0.47

8-32 stud

30.6/1.21

30.6/1.21

ELECTRONIC HID

11

12

64.8/2.55

72.1/
2.84

76.0/2.99

92.0/
3.62

46.0/
1.31
86.8/3.42

133.5/5.26

95.1/3.74

140.0/5.51
39.9/1.57

31.8/1.25

PAGE 5-6

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Dimensions
13

14

92.0/3.62

92.0/
3.62

46.0/1.31

127.5/5.02
8-32 stud

133.5/5.26

50.8/2.0

11.4/0.45
39.9/1.57

39.9/1.57

15

16

92.0/3.62

72.1/
2.84
92.0/
3.62

46.0/
1.31

46.0/1.31

127.5/5.02
8-32 stud

133.5/5.26

50.8/2.0

140.0/5.51

11.4/0.45

39.9/1.57

39.9/1.57

17

72.0/
2.84
92.0/
3.62

46.0/
1.31
202.0/ 7.95
208.0/ 8.19

60.0/2.36

ELECTRONIC HID

PAGE 5-7

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Application And Operating Information
General:
If the electrical current through an HID lamp is properly stabilized, an HID plasma arc with very high luminous efficiency is created
in the arc tube chamber resulting in a very efficient light source. The internal pressure of the arc tube chamber rises as the arc tube
temperature increases and will attain between 1 and 10 bar; thereby, defining these lamps as high-pressure HID lamps, high intensity discharge lamps or simply HID lamps. The light output and color rendition of HID lamps vary considerably depending on the lamp
family (mercury, metal halide or sodium lamps).
HID lamps can only be started and operated with ballasts. Ignitors or ignition voltage characteristics are additionally required for
sodium and metal halide lamps. As well as stabilizing the lamp’s operating point, ballasts also influence the lamp’s output and luminous flux, the system light output, the service life of the lamps as well as the color temperature of the light source.
Electromagnetic or electronic ballasts can be used for HID lamps, but unlike fluorescent lamps, lamp
efficiency is not significantly improved by the use of electronic ballasts. However, electronic ballasts can
lead to a reduction of the inherent losses and thus to an increase in system efficiency. In addition,
electronic ballasts can ensure gentle lamp operation, which may increase lamp’s service life.
Electronic Ballasts for Metal Halide Lamps
Electronic ballasts are designed with all the components required to operate metal halide lamps, including ignition, power factor
correction, and stable normal operation. Furthermore, they safely shutdown lamps at the end of their service life to prevent high
temperatures from being generated in the luminaires that could influence the service life of the luminaire or its components.
Universal Lighting Technologies also provides special electronic ballasts for additional luminaire functions such as heater power for
insulation detection thermal protectors and for switching on of an auxiliary incandescent lamp for the dark phase of an HID lamp
during initial warm-up or during hot-restrike cool-down mode.
Standards/Regulations
ANSI C82.14

Low-Frequency Square Wave Electronic Ballasts for Metal Halide Lamps

UL 1598

Standard for Safety-Luminaires

ANSI C82.77

Harmonic Emission Limits-Related Power Quality Requirements
or Lighting Equipment

ANSI/UL 1029

Standard for Safety-High Intensity HID Lamp Ballasts

ANSI/IEEE C62.41

Surge Voltages in Low Voltage AC Power Circuits

ELECTRONIC HID

US Code of Federal Regulations Title 47 –Telecommunications Part 18– Industrial, Scientific and Medical Devices

PAGE 5-8

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Application And Operating Information
Technical Specifications:
Operating voltage range
120VAC rated: 120V 277V ±10%
277VAC rated: 277V ±10%
120–277V rated: 108V–305V
120/277V rated: 108V–132V and 249V–305V
Leakage current	

≤0.5mA

Hot restrike auxiliary lamp operation
In order to ensure continuous illumination even during the ignition period or in the event of a lamp drop-out due to short term power
outage, an additional incandescent lamp (maximum 150W) can be used on models designated with a JA suffix.
Short circuit issues
The ballast output metal halide lamp leads are basically short-circuit-proof. However, any shorts or connections between those lamp
leads to the ballast case or to safetyneutral (earth ground) will destroy the ballasts. Likewise the metal halide lamp leads
shall not be connected to input power connections nor shall the auxiliary lamp leadsbe shorted together otherwise the ballast’s
circuitry could be damaged or fail.
Provisions in the luminaire design should be implemented to prevent all lead wires but especially lamp leads from being pinched,
damaged, or cut during luminaire assembly, field installation or normal service.

Mechanical Mounting:
Surface
Firm, flat, preferably metal surface required to ensure good heat transfer for long ballast service life and reliability. Avoid mounting on
uneven or protruding surfaces.
Mounting Location
Electronic ballasts must be protected against moisture and heat. Outdoor applications must utilize luminaires with the appropriate
weatherproof ratings depending on location. Most Universal Lighting Technologies electronic ballasts are rated “Outdoor Type 1”.
Fastening
Use mechanical means to ensure ballasts are fixed tightly to flat surfaces. Use appropriately sized screws depending on the
ballast mounting slot size or spring clips to provide interference fit.

If ballast is destined for installation in a luminaire, sufficient heat transfer must be ensured between the electronic ballast and the
luminaire housing. Electronic ballasts should be mounted with the greatest possible clearance from heat sources or lamps.
During operation, the temperature measured at the ballast’s tc point must not exceed the specified maximum value.

PAGE 5-9

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

ELECTRONIC HID

Heat transfer

Application And Operating Information
Technical Specifications:
• Dimensional tolerances:
– Case: ±1mm (±0.039”)
– Standard lead length tolerances: +50mm (+2”) or –30mm (–1”) Micro lead length tolerances: ±15mm (±0.6”)
– Slot width on “F” mounting tabs: 5mm (0.20”); for Mini-Square Size: 4mm (0.157”)
• Remote wiring guidelines:
– Each lamp’s lead wires must be run in a separate conduit from the input power leads to achieve good EMI performance and
	 maximum remote capabilities. Lamp leads shall not be bundled together, but each set of lamp leads shall be run in its own conduit.
– Individual lamp lead wires must be used for external fixture wire extensions using wire types SF-2 (equivalent to SEW-2 or
	 3071) or SFF-2 (equivalent to SEWF-2 or 3070) or alternately, if approved by ULT, high voltage luminaire wire with a 18AWG
	 conductor and a 1000VAC minimum voltage rating. Temperature rating is especially critical if the lamp lead extension wires
	 are directly connected to lampholder terminals.
– Maximum remote distances:
See individual model specification sheets.
The specified maximum remote distances are based on lamp leads run in a minimum ½” internal diameter
conduit, pipe or flexible conduit. For longer remote distances contact the TES group at Universal Lighting.
– Using service power cords (types SJ, SO, ST, SV etc.) or metal clad cable assemblies for lamp lead extension wire are not
recommended as they are not compatible with the above characteristics, can cause starting problems and shall not be used
unless ULT gives written approval.
Insulation clearance

ELECTRONIC HID

Remote mounted ballasts shall be installed per National Electrical Code and local codes while also complying with wiring
methods per Universal Lighting Technologies recommendations. Per UL requirements, thermal insulation shall be a minimum
of 3” from any ballast surface.

PAGE 5-10

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Application And Operating Information
Safety Functions:
Regulatory approvals
Universal Lighting Technologies electronic HID ballasts are UL listed or UL recognized component and cUL listed for use in Canada.
Shutdown of defective lamps
In the event of a lamp failing to ignite or of a lamp with low or high operating voltages (end of lamp’s service life), the electronic
ballast will switch off after a defined period of time (typically 30 minutes). The ballast will also shut-down if the lamp fails to achieve
symmetrical current operation (rectification) or if lamp leads are shorted to each other. After lamp replacement, the ballast output can
be reset by disconnecting (count to 10) and then reconnecting input power.
Transient input voltage
Electronic ballasts incorporate transient protection that complies with ANSI C62.41 and ANSI C82.14 test procedure and values.
Temperature Protection
To prevent excess temperatures, ballasts contain thermal protection devices or thermal sensing circuitry. A ballast will restart after it
has cooled down, however, it might be necessary to briefly reset the input power after the over-temperature condition is resolved.
General guidelines
Always disconnect power to the luminaire before installation or service of the ballasts. Install to all provisions of local or National
Electric Codes. The ballast case/green lead must be grounded. Dispose of any replaced ballasts or lamps properly per local
environmental regulations.

Reliability and Service Life:
The electronic ballast service life is inversely proportional to the temperature of its critical internal components. Normal ballast
operation shall have the temperature of the tc point less than the warranted values in the individual specification sheets

Electrical Installation:
3-Phase connection of luminaires with electronic ballasts

Power factor compensation
Luminaires with electronic ballasts do not need power factor compensation, as the typical power factor range of electronic
ballasts is 95 to 99%.

PAGE 5-11

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

ELECTRONIC HID

Prior to operating newly installed lighting systems, please check the ballast’s rated voltage range to ensure it is appropriate
for the job site input power supply voltage. The neutral power supply wire must be connected securely to all luminaires and to
all ballasts. Power supply conductors must only be connected or disconnected when the circuit is not energized. The neutral
conductor must never be disconnected as the first disconnected wire nor individually at the circuit panel, at a distribution wiring
junction box or at the luminaire during energized power supply operation as out-of balance voltage operation can lead to serious
over-voltages and subsequent ballast failures.

Application And Operating Information
Wiring
Wiring between the power supply, electronic ballasts and lamp must comply with the respective circuit diagram.
Note: the ballast (metal) case (using toothed washer) or provided green lead must be connected to safety-neutral (earth ground).
In addition, all metal luminaire parts and metal lamp reflector/housings shall also be connected to earth ground for safety and for
proper lamp starting. Metal halide luminaires must only be fitted with electrical components that are rated to withstand ignition voltages of 4kV. To ensure compliance with RFI suppression limits, input and output conductors should not be run in the same conduit as
lamp conductors. Conduit size recommendations are stated in the individual ballast specification sheets or
construction notes.
Lamp maintenance notice
To replace end-of-service lamps, turn-off luminaire power, remove and replace lamps then turn-on luminaire power. If power was not
turned off during lamp replacement, the luminaire/ballast-input power must be reset to restart the new lamp. If the lamp or wiring is
defective, the ballast will “shut-down” in 1.5 to 30 minutes depending upon the fault condition.
Supplemental IDTP wiring
The IDTP (insulation detector thermal protector) is required by UL for most recessed luminaires. This fast acting thermal
protector is typically mounted on the same junction box as the electronic ballast. Special “JT” electronic ballasts provide a
separate 120V power supply for the IDTP heater to allow the luminaire to be rated for both 120V and 277V operation. See the
individual ballast specifications for the proper wiring procedures for JT & JA ballasts with this IDTP heater function.
Note: When using JT or JA ballasts on multiple lamp luminaires, only one ballast yellow or purple lead should be connected to the
IDTP heater. All other ballasts’ yellow or purple leads should be capped-off. Operation of JT and JA ballasts on 208V and 240V is not
recommended, as the IDTP may not function properly.
Lamp compatibility
Not all HID lamps are compatible with all electronic ballasts. Therefore, consult with Universal Lighting Technologies Technical
Support or a specific lamp company regarding a certain lamp’s compatibility.
External fuse ratings

ELECTRONIC HID

All Universal Lighting Technologies electronic HID ballasts have internal fuses for EOL protection; however, if external fuses
are specified, use a 3A slow blow fuse for 20W-100W ballasts and a 5A slow blow fuse for 150W & 210W ballasts.

PAGE 5-12

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Notes

ELECTRONIC HID

PAGE 5-13

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Vossloh Schwabe, a subsidiary of the
Panasonic group, has been manufacturing
and providing lampholders of the highest
quality and reliability to the European and
US markets since 1920. With products
available to meet all your lamp, ballast,
and fixture requirements, these lampholders
will deliver peace of mind for years to come.

LAMPHOLDERS

Universal Lighting Technologies is a member of the Panasonic Group

Application And Operating Information
Mounting Styles:
With the different fixture designs and applications in the market there are a number of lampholder mounting configurations
available to meet all applications. These mounting styles, while demonstrated and geared towards linear fluorescent lamps,
are also applicable to compact fluorescent lampholders as well.

Push Through:
The push through lampholder is the most common
in the United States. This lampholder is inserted into
a rectangular cut-out in the fixture and snaps into
place with ballast wires being inserted into the base
from underneath.

Snap-In:
Snap-In lampholders are available in two styles.
The first is very similar application wise to the push
through style with the difference being that it is
pushed into the fixture from the top instead of the
bottom. These lampholders wire from the bottom
of the fixture as well. The second variant snaps in
from the top as well but uses pin holes instead of a
rectangular cutout. This allows the customer to use
that actual fixture to mount the lampholder instead
of a dedicated socket bar. Wiring this type of
lampholders is done either through the bottom or
laterally through the sides of the lampholder.

LAMPHOLDERS

Butt On:
These lampholders are designed to mount directly
to the sides of the fixture and are available with
two mounting options. One has through holes for
M3 screws, the second has pins either laterally or
vertically across the back of the lampholder that
snap into two pre-drilled holes in the fixture housing.
Both models are available with spring mounts and
two different thicknesses (9mm and 13.5mm).
Contact egress is available from the side or bottom
of the lampholder.

PAGE 6-2

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Application And Operating Information
Slide On:
These lampholders simply slide onto the end of
a fixture into a knocked out channel. All version
of this lampholder wire from the bottom.

Slides into existing channel
at the end of the fixture

Rotor Styles:
Integrated Rotor:
Our integrated rotor system is a single piece construction that is simple and easy to use with no
moving parts and an easy lamp insertion force.
Moving Rotor:
Moving rotor systems have a separate piece in the center of the lampholder that rotates with the
lamp to aid in locking it in place. Two different systems are available; the Big Rotor system and
our Roto-Clic system which has an audible click when the lamp is fully seated in the lampholder.

Shunting:
Non-Shunted lampholder have two individual contacts inside, one contact for each pin of the lamp.
Each contact has its own separate wire terminal on either side of the lampholder. This type of
lampholder is used with programmed or rapid start ballasts.
Shunted lampholders have one continuous contact running through the lampholder that electrically
connects both pins of the lamp together. These lampholders will only have push in contacts on one
side of the lampholder and are used with instant-start ballasts.

Lamp Axis:
Lamp axis is the distance from the surface of the
fixture to the center of the lamp. For T8 and T12
lamps, these are commonly referred to as low
profile for T8 only (16mm), standard (23mm),
and tall (31mm) and can vary by a couple mm
from manufacturer to manufacturer.
ELECTRONIC HID

PAGE 6-3

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Application And Operating Information
Lamp Stop:
Lamp stop or “nib” as it is sometime called is a small pin the
extends up from the front of some push through lampholders.
This can be used to assist in locating the lampholder in the
fixture or to help provide a slight inward rake to the lampholder.

Lampholder Springs:
Butt-On style lampholders can be purchased with or without a
spring. These are small metal clips on the rear of the lampholder
that help to provide compression on the lamp. They can be used
on either side of the fixture or both as required by the manufacturer.

Circle I:
This stems from a UL requirement for instant start systems to contain either a type CC rated ballast or a “Circle I” rated lampholder.
At this time, all of our shunted or instant start lampholders meet this requirement and are marked accordingly with the I mark.

Nomenclature:
Our lampholders carry both a type number and a reference number. The type number is more like a family number where the
numeric character signify similarities and differences as you progress through the five digit number. For example, the 291xx series
are all 23mm, push-through, lampholders for T8/T12 lamps. As you move further into these numbers it signifies other identifiers
like shunting and stopping pins. The reference number is the orderable number that is used to order the exact product.

Packaging:
Standard packing through ULT is in full bag quantities. For linear fluorescent lampholders this is commonly 1,000 piece, for compact
fluorescent 500, and for HID, Halogen, and eHID this ranges from 10-250 pieces. Packing quantities vary by model and are listed on
all spec sheets.

ELECTRONIC HID

A select number of our lampholders are available in smaller “distributor friendly” packages, please consult your ULT sales
representative for more information.

PAGE 6-4

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Snap-In Lampholders

T8 & T12

Snap-In Lampholders
Reference Number

Lamps

Lamp Axis (mm)

Shunted

Push-In Terminals

Recommended Cut-Out (mm)

Drawing

Weight

Unit Pcs.

23370

539128

T8

18

-

Lateral

ø5.5 x 23

1

5.3

1000

23372

539140

T8

18

Shunted Right

Lateral

ø5.5 x 23

1

5.3

1000

23374

539141

T8

18

Shunted Left

Lateral

ø5.5 x 23

1

5.3

1000

24350

537153

T8/T12

23.5

-

Base

ø5.5 x 23

2

5.7

1000

24352

536320

T8/T12

23.5

Shunted

Base

ø5.5 x 23

2

5.7

1000

23350

537157

T8/T12

23.5

-

Lateral

ø5.5 x 23

1

5.8

1000

23352

536293

T8/T12

23.5

Shunted Right

Lateral

ø5.5 x 23

1

5.8

1000

23354

536294

T8/T12

23.5

Shunted Left

Lateral

ø5.5 x 23

1

5.8

1000

24360

537155

T8/T12

30

-

Base

ø5.5 x 23

2

5.9

1000

24362

536322

T8/T12

30

Shunted

Base

ø5.5 x 23

2

5.9

1000

23360

537160

T8/T12

30

-

Lateral

ø5.5 x 23

1

6

1000

23362

536284

T8/T12

30

Shunted Right

Lateral

ø5.5 x 23

1

6

1000

23364

537160

T8/T12

30

Shunted Left

Lateral

ø5.5 x 23

1

6

1000

24150

537144

T8

18

-

Lateral

13.3 x 25.5

3

5.4

1000

21452

536309

T8

18

Shunted Right

Lateral

13.3 x 25.5

3

5.4

1000

24154

536310

T8

18

Shunted Left

Lateral

13.3 x 25.5

3

5.4

1000

24140

537141

T8

18

-

Lateral

10 x 20

5

6

1000

24142

536306

T8

18

Shunted Right

Lateral

10 x 20

5

6

1000

24144

536307

T8

18

Shunted Left

Lateral

10 x 20

5

6

1000

24170

537150

T8/T12

21

-

Lateral

13.3 x 25.5

3

5.6

1000

24172

536315

T8/T12

21

Shunted Right

Lateral

13.3 x 25.5

3

5.6

1000

24174

536316

T8/T12

21

Shunted Left

Lateral

13.3 x 25.5

3

5.6

1000

24160

537147

T8/T12

21

-

Lateral

10 x 20

5

6

1000

24162

536312

T8/T12

21

Shunted Right

Lateral

10 x 20

5

6

1000

24164

536313

T8/T12

21

Shunted Left

Lateral

10 x 20

5

6

1000

24100

537132

T8/T12

25

-

Lateral

13.3 x 25.5

3

9

1000

24102

536297

T8/T12

25

Shunted Right

Lateral

13.3 x 25.5

3

9

1000

24104

536298

T8/T12

25

Shunted Left

Lateral

13.3 x 25.5

3

9

1000

24110

537165

T8/T12

25

-

Lateral

13.3 x 25.5

4

9

1000

24112

536300

T8/T12

25

Shunted Right

Lateral

13.3 x 25.5

4

9

1000

24114

536301

T8/T12

25

Shunted Left

Lateral

13.3 x 25.5

4

9

1000

24120

537138

T8/T12

25

-

Lateral

10 x 20

5

5.7

1000

24122

536303

T8/T12

25

Shunted Right

Lateral

10 x 20

5

5.7

1000

24124

536304

T8/T12

25

Shunted Left

Lateral

10 x 20

5

5.7

1000

* Consult www.UNVLT.com for complete lampholder offering and complete specs.

1

3

2

4

PAGE 6-5

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

LAMPHOLDERS

Type

Push-Through, Slide-On Lampholders

T8 & T12

Push-Through Lampholders
Type

Reference Number

Lamps

Lamp Axis (mm)

Shunted

Lamp Stop

Recommended Cut-Out (mm)

Drawing

Weight (g)

29300

509134

T8

16

-

W/ Stop

9 x 25.5

6

4.7

Unit Pcs.
1000

29300

509136

T8

16

Shunted

W/ Stop

9 x 25.5

6

4.7

1000

29301

509135

T8

16

-

-

9 x 25.5

6

4.5

1000

29301

509137

T8

16

Shunted

-

9 x 25.5

6

4.5

1000

29100

545845

T8/T12

23

-

W/Stop

9 x 25.5

7

6.8

1000

29101

545849

T8/T12

23

-

-

9 x 25.5

7

6.8

1000

29125

545840

T8/T12

23

Shunted

W/Stop

9 x 25.5

7

6.8

1000

29126

545842

T8/T12

23

Shunted

-

9 x 25.5

7

6.8

1000

28700

109342

T8/T12

31

-

W/ Stop

9 x 25.5

9

7.8

1000

28725

109376

T8/T12

31

Shunted

W/ Stop

9 x 25.5

9

7.8

1000

28701

109343

T8/T12

31

-

-

9 x 25.5

9

7.8

1000

28726

109377

T8/T12

31

Shunted

-

9 x 25.5

9

7.8

1000

* Consult www.UNVLT.com for complete lampholder offering and complete specs.

Slide-On Lampholders
Type

Reference Number

Lamps

Lamp Axis (mm)

Shunted

Lamp Stop

Recommended Cut-Out (mm)

Drawing

Weight (g)

Unit Pcs.

29150

545858

T8/T12

23

-

0.5 - 0.8

9.15 x 26.2

10

6.8

1000

29155

545862

T8/T12

23

Shunted

0.5 - 0.8

10

6.8

1000

LAMPHOLDERS

* Consult www.UNVLT.com for complete lampholder offering and complete specs.

6

9

7

10

PAGE 6-6

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Butt-On Lampholders

T8 & T12

Butt-On Lampholders
Type

Reference Number

Lamps

Lampholder
Thickness

49505

537174

T8/T12

9.5

-

-

ø4.2 x 26

11

5

1000

49525

536337

T8/T12

9.5

Shunted

-

ø4.2 x 26

11

5

1000

49506

537175

T8/T12

9.5

-

X

ø4.2 x 26

12

5.5

1000

49526

536338

T8/T12

9.5

Shunted

X

ø4.2 x 26

12

5.5

1000

59505

537206

T8/T12

9.5

-

-

ø4.2 x 26

13

4.8

1000

59525

536369

T8/T12

9.5

Shunted Right

-

ø4.2 x 26

13

4.8

1000

59545

536373

T8/T12

9.5

Shunted Left

-

ø4.2 x 26

13

4.8

1000

59506

537207

T8/T12

9.5

-

X

ø4.2 x 26

14

4.8

1000

59526

536370

T8/T12

9.5

Shunted Right

X

ø4.2 x 26

14

4.8

1000

59546

536347

T8/T12

9.5

Shunted Left

X

ø4.2 x 26

14

4.8

1000

49105

537166

T8/T12

13

-

-

ø4.2 x 26

11

5.1

1000

49125

536329

T8/T12

13

Shunted

-

ø4.2 x 26

11

5.2

1000

49106

537167

T8/T12

13

-

X

ø4.2 x 26

12

5.9

1000

49126

536330

T8/T12

13

Shunted

X

ø4.2 x 26

12

5

1000

59105

537182

T8/T12

13

-

-

ø4.2 x 26

13

5

1000

59125

536325

T8/T12

13

Shunted Right

-

ø4.2 x 26

13

5

1000

59145

536349

T8/T12

13

Shunted Left

-

ø4.2 x 26

13

5

1000

59106

537183

T8/T12

13

-

X

ø4.2 x 26

14

5

1000

59126

536346

T8/T12

13

Shunted Right

X

ø4.2 x 26

14

5

1000

59146

536350

T8/T12

13

Shunted Left

X

ø4.2 x 26

14

5

1000

49500

537173

T8/T12

9.5

-

-

Holes 25mm O.C.

15

5

1000

49520

536336

T8/T12

9.5

Shunted

-

Holes 25mm O.C.

15

5

1000

47502

101740

T8/T12

9.5

-

X

Holes 25mm O.C.

16

5.5

1000

59500

537205

T8/T12

9.5

-

-

Holes 25mm O.C.

17

4.7

1000

59520

536368

T8/T12

9.5

Shunted Right

-

Holes 25mm O.C.

17

4.7

1000

59541

536372

T8/T12

9.5

Shunted Left

-

Holes 25mm O.C.

17

4.7

1000

49100

537165

T8/T12

13

-

-

Holes 25mm O.C.

15

5

1000

49120

536328

T8/T12

13

Shunted

-

Holes 25mm O.C.

15

5

1000

47102

404681

T8/T12

13

-

X

Holes 25mm O.C.

16

6

1000

59100

537181

T8/T12

13

-

-

Holes 25mm O.C.

17

5

1000

59420

536344

T8/T12

13

Shunted Right

-

Holes 25mm O.C.

17

5

1000

59140

536348

T8/T12

13

Shunted Left

-

Holes 25mm O.C.

17

5

1000

Shunted

Spring
Adjustment

Recommended Cut-Out (mm)

Drawing

Weight

Unit Pcs.

11

13

12

14

PAGE 6-7

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

LAMPHOLDERS

* Consult www.UNVLT.com for complete lampholder offering and complete specs.

Butt-On Lampholders

T8 & T12

15

17

LAMPHOLDERS

16

PAGE 6-8

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Push-Through, Snap-In, Butt-On Lampholders

T5

Push-Through Lampholders
Type

Reference Number

Lamps

Lamp Axis

Lamp Stop

Recommended Cut-Out (mm)

Drawing

Weight

Unit Pcs.

09420

505737

T5/T5HO

15

X

9.7 x 19.5

1

3.4

1000

09421

505739

T5/T5HO

15

-

9.7 x 19.5

1

3.3

1000

09432

545933

T5/T5HO

20

X

9.7 x 19.5

2

3.6

1000

09433

545935

T5/T5HO

20

-

9.7 x 19.5

2

3.6

1000

09434

545937

T5/T5HO

25

X

9.7 x 19.5

3

3.9

1000

09435

545939

T5/T5HO

25

-

9.7 x 19.5

3

3.9

1000

09426

505745

T5/T5HO

35

X

9.7 x 19.5

4

4.5

1000

09427

505746

T5/T5HO

35

-

9.7 x 19.5

4

4.5

1000

09105

100305

T5/T5HO

13.2

Screw Fixing

9.7 x 19.5

5

3.2

1000

Lamp Stop

* Consult www.UNVLT.com for complete lampholder offering and complete specs.

Snap-In Lampholders
Type

Reference Number

Lamps

Lamp Axis

Recommended Cut-Out (mm)

Drawing

Weight

Unit Pcs.

09440

505747

T5/T5HO

14

9.7 x 19.5

6

3.3

1000

09446

545894

T5/T5HO

18

9.7 x 19.5

7

3.5

1000

09447

545896

T5/T5HO

23

9.7 x 19.5

8

3.8

1000

09450

505750

T5/T5HO

15

ø3.7 x 13.2

9

3.4

1000

09460

505751

T5/T5HO

11.8

ø3.2 x 19.5

10

3.1

1000

09465

508314

T5/T5HO

11.8

ø3.2 x 19.5

11

3.1

1000

ø3.2 x 18

* Consult www.UNVLT.com for complete lampholder offering and complete specs.

Butt-On Lampholders
Type

Reference Number

Lamps

Lampholder
Thickness

Spring
Adjustment

09404

505732

T5/T5HO

9.3

-

09405

505733

T5/T5HO

9.3

-

09406

505734

T5/T5HO

9.3

09407

508590

T5/T5HO

09415

505735

09416
09205

Recommended Cut-Out (mm)

Drawing

Weight

Unit Pcs.

13

2.8

1000

ø3.8 x 20

14

2.9

1000

X

ø3.8 x 20

14

3.3

1000

12.5

-

ø3.8 x 20

15

3

1000

T5/T5HO

9.3

-

ø3.8 x 10

16

2.9

1000

505736

T5/T5HO

9.3

X

ø3.2 x 10

16

3.2

1000

100310

T5/T5HO

9.3

-

ø3.2 x 10

17

2.5

1000

1

3

2

4

PAGE 6-9

LAMPHOLDERS

* Consult www.UNVLT.com for complete lampholder offering and complete specs.

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Butt-On Lampholders

T5
11

5

13

6

14

7

LAMPHOLDERS

15

16
8

9
17

10

PAGE 6-10

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

GU6.5, G8.5, GX8.5, GY9.5, GX10, G(X)12,
K12S-7, PGJ5, RX7s Lampholders

Type

Reference
Number

Lamp
Type

Material

Mounting

34515

534218

GU6.5

Ceramic

34516

534219

GU6.5

34525

538634

GU6.5

HID

Lead
Length

Lead Material

Drawing

Weight

Unit Pcs.

#4 Screw Holes 15mm OC

305mm

PTFE

1

20

100

Ceramic

Threaded #4 Holes 15mm OC

305mm

PTFE

1

20

100

Ceramic

#4 Screw Holes 15mm OC

200mm

PTFE

2

15

100

GU6.5

G8.5
33650

526018

G8.5

Ceramic

#4 Screw Holes 15mm OC

Terminals

N/A

3

12.6

150

33600

502394

G8.5

Ceramic

#4 Screw Holes 15mm OC

Terminals

N/A

3

5

1000

34650

547807

GX8.5

LCP

#4 Screw Holes 23mm OC

Terminals

N/A

4

11.9

50

34651

547808

GX8.5

LCP

#4 Screw Holes 23mm OC

Terminals

N/A

4

12.6

50

37002

534105

GY9.5

Ceramic

#4 Screw Holes 30mm O.C.

305mm

SF-2

5

62

25

100

GX8.5

GY9.5
GX10
31550

543963

GX10

Steatitie

#4 Screw Holes 18mm OC

200mm

7

21.7

31550

543153

GX10

Steatitie

#4 Screw Holes 18mm OC

305mm

7

25

100

31400

509356

GX10

PPS

#4 Screw Holes 18mm OC

Terminals

8

9.2

100

31402

537049

GX10

PPS

#4 Screw Holes 18mm OC

240mm

8

33.9

100

31402

534636

GX10

PPS

#4 Screw Holes 18mm OC

460mm

8

33.9

100

31402

534050

GX10

PPS

#4 Screw Holes 18mm OC

765mm

8

33.9

100

31402

536822

GX10

PPS

#4 Screw Holes 18mm OC

915mm

8

33.9

100

25

N/A

G(X)12
31921

526251

G12

Ceramic

#8 Screw Holes 30mm OC

765mm

PTFE

9

72

31921

529773

G12

Ceramic

#8 Screw Holes 30mm OC

1170mm

PTFE

9

88

25

31936

108257

G12

Ceramic

#8 Screw Holes 30mm OC

460mm

SF-2

10

56

25

31936

525750

G12

Ceramic

#8 Screw Holes 30mm OC

765mm

SF-2

10

72

25

31936

526211

G12

Ceramic

#8 Screw Holes 30mm OC

1524mm

SF-2

10

144

25

42000

509213

G12

LCP

#8 Screw Holes 30mm OC

N/A

N/A

11

20

25

41900

507656

GX12

Ceramic

#8 Screw Holes 30mm OC

300mm

SI

12

58.5

25

21100

107652

K12s-7

Ceramic

N/A - Socket Only

Terminals

N/A

13

25

25

21100

107677

K12s-7

Ceramic

#10 Screw Holes 61.4mm OC

Terminals

N/A

13

70

25

K12s-7

34155

538630

PGJ5

Ceramic

#4 Screw Holes 11.6mm OC

460mm

PTFE - Lat

14

21.7

100

34116

534102

PGJ5

Ceramic

#4 Screw Holes 11.6mm OC

305mm

PTFE - Cent

15

11.5

100

34116

537057

PGJ5

Ceramic

#4 Screw Holes 11.6mm OC

460mm

PTFE - Cent

15

18.6

100

34116

537784

PGJ5

Ceramic

#4 Screw Holes 11.6mm OC

765mm

PTFE - Cent

15

27.8

100

34125

537454

PGJ5

Ceramic

#4 Screw Holes 11.6mm OC

200mm

PTFE - Lat

16

10.5

100

34125

535782

PGJ5

Ceramic

#4 Screw Holes 11.6mm OC

305mm

PTFE - Lat

16

12.5

100

34125

542304

PGJ5

Ceramic

#4 Screw Holes 11.6mm OC

460mm

PTFE - Lat

16

14.5

100

30608

108913

RX7s

Ceramic

#8 Screw Holes 34mm OC

460mm

PTFE

17

72

25

30611

100732

RX7s

Ceramic

#8 Screw Holes 34mm OC

305mm

SF-2

17

68

25

31662

107065

RX7s

PPT

#8 Screw Holes 34mm OC

300mm

SI

18

23

25

32301

506216

RX7s

Ceramic

Captive mounting for #8 Screw

360mm

SF-2

19

34

300

32330

100928

RX7s

Ceramic

Central tapped hole for #8 Screw

300mm

SI

19

75

200

RX7s

PAGE 6-11

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

LAMPHOLDERS

PGJ5

E26, E39 Lampholders

HID

Type

Reference
Number

Lamp
Type

Material

Mounting

Lead
Length

Lead Material

Drawing

Weight

Unit Pcs.

62609

109459

E26

Porcelain

#8 Screw Holes 18mm OC

62610

525523

E26

Terminals

N/A

20

64

200

Porcelain

Bushings for #8 Screw 18mm OC

Terminals

N/A

20

64

62030

102597

200

E26

Porcelain

#8 Screw Holes 18mm OC

Terminals

N/A

21

61

64707

200

504262

E26

PET - White

ST #7 Screws 18mm OC

Terminals

N/A

22

15.4

64707

500

506381

E26

PET - Black

ST #7 Screws 18mm OC

Terminals

N/A

22

15.4

500

E26

E39
12870

109014

E39

Porcelain

Bushings 35mm OC

Terminals

N/A

23

190

50

12876

109518

E39 w/grip

Porcelain

Bushings 35mm OC

Terminals

N/A

23

190

50

12850

108851

E39

Porcelain

#10 Screw Holes 30mm OC

Terminals

N/A

24

208

50

12851

109272

E39 w/grip

Porcelain

#10 Screw Holes 30mm OC

Terminals

N/A

24

208

50

12860

108869

E39

Porcelain

Bracket for #10 Screws 56.5mm OC

Terminals

N/A

25

219

50

12861

109460

E39 w/grip

Porcelain

Bracket for #10 Screws 56.5mm OC

Terminals

N/A

25

219

50

12862

108870

E39 w/grip

Porcelain

Bracket for #10 ST Screws 56.5mm OC

Terminals

N/A

26

227

50

12650

501981

E39

PPS

#10 Screw Holes 30mm OC

Terminals

N/A

27

109

50

12660

501982

E39

PPS

Bracket for #10 Screws 56.5mm OC

Terminals

N/A

28

119

50

LAMPHOLDERS

1

2

3

4

5

6

PAGE 6-12

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID Lampholders

7

HID

13

8

14

9

15

10

LAMPHOLDERS

16

11

17

12

PAGE 6-13

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

HID Lampholders

HID

18

23

24

19

25
20

LAMPHOLDERS

26

21

27

22
28

PAGE 6-14

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

B15d, G(Z)4 G(X)5.3 G(Y)6.35,
G(Z)4, G9, G53, GU4 Lampholders

Type

Reference
Number

Lamp Type

Material

Mounting

48101

108925

B(A)15d

Steel/Ceramic

48102

102927

B(A)15d

78103

102929

B(A)15d

HALOGEN

Lead
Length

Lead Material

Drawing

Weight

Unit Pcs.

#4 Screw Holes 25.5mm OC

Terminals

w/ground

1

16

500

Steel/Ceramic

#4 Screw Holes 25.5mm OC

Terminals

N/A

2

17

500

Steel/Ceramic

#4 Screw Holes 25.5mm OC

Terminals

w/ground

2

18

500

B15d

G(Z)4 G(X)5.3 G(Y)6.35
32400

109855

G4/G5.3/G6.35

Ceramic

#4 Screw Holes 11.5mm OC

152mm

PTFE

3

8.1

1000

32400

536857

G4/G5.3/G6.35

Ceramic

#4 Screw Holes 11.5mm OC

200mm

PTFE

3

8.3

1000

32400

109856

G4/G5.3/G6.35

Ceramic

#4 Screw Holes 11.5mm OC

300mm

PTFE

3

8.5

1000

32400

525681

G4/G5.3/G6.35

Ceramic

#4 Screw Holes 11.5mm OC

665mm

PTFE

3

8.8

1000

32400

100946

G4/G5.3/G6.35

Ceramic

#4 Screw Holes 11.5mm OC

750mm

PTFE

3

9

1000

32480

504542

G4/G5.3/G6.35

Ceramic

#4 Screw Holes 11.5mm OC

300mm

PTFE

4

8.8

1000

32700

109851

G4/G5.3/G6.35

Ceramic

#4 Screw Holes 11.4mm OC

155mm

PTFE

5

12.8

1000

32700

109852

G4/G5.3/G6.35

Ceramic

#4 Screw Holes 11.4mm OC

305mm

PTFE

5

12.8

1000

32700

109853

G4/G5.3/G6.35

Ceramic

#4 Screw Holes 11.4mm OC

590mm

PTFE

5

12.8

500

32720

525857

G4/G5.3/G6.35

Ceramic

#4 Screw Holes 26mm OC

320mm

PTFE

6

8.7

1000

32720

529699

G4/G5.3/G6.35

Ceramic

#4 Screw Holes 26mm OC

960mm

PTFE

6

8.7

1000

G(Z)4
30449

530250

G(Z)4

PPS

#4 Screw Holes 20mm OC

140mm

PTFE

7

3.8

1000

60464

108892

G(Z)4

PPS

N/A

Terminals

N/A

9

2.2

1000

60469

108893

G(Z)4

PPS

N/A

Terminals

N/A

10

1.9

1000

32500

101035

G(Z)4

PPS

#4 Screw Holes 12mm OC

140mm

PTFE

11

8.7

500

32500

509069

G(Z)4

PPS

#4 Screw Holes 12mm OC

195mm

PTFE

11

8.9

500

32500

509035

G(Z)4

PPS

#4 Screw Holes 12mm OC

765mm

PTFE

11

9.8

500

33710

508306

G9

LCP

20.8x2 Ext, #3 Holes 14mm OC

Terminals

N/A

12

6

1000

33711

520728

G9

LCP

20.8x2 Ext, #4 Holes 23mm OC

Terminals

N/A

13

8.7

1000

33721

508610

G9

Ceramic

20.8x2 Ext, #4 Holes 23mm OC

Terminals

N/A

13

10.6

1000
1000

G9

508611

G9

Ceramic

20.8x2 Ext, #4 Holes 23mm OC

Terminals

N/A

13

10.2

509357

G9

Ceramic/LCP

N/A

Terminals

N/A

14

7.5

1000

33900

534132

G9

Ceramic

N/A

140mm

PTFE

15

14.2

1000

33500

502004

G9

Ceramic

#4 Screw Holes 17mm OC

Terminals

N/A

16

16

1000

140mm

PTFE

17

3.8

1000

G53
33100

107694

G53

PPS

#8 Screw Holes

GU4
32400

109855

GU4

Ceramic

#4 Screw Holes 11.5mm OC

152mm

PTFE

18

8.1

1000

32400

109856

GU4

Ceramic

#4 Screw Holes 11.5mm OC

300mm

PTFE

18

8.1

1000

32400

525681

GU4

Ceramic

#4 Screw Holes 11.5mm OC

665mm

PTFE

18

8.1

1000

32400

536857

GU4

Ceramic

#4 Screw Holes 11.5mm OC

200mm

PTFE

18

8.1

1000

32412

538286

GU4

Ceramic

460mm

PTFE

18

8.1

1000

32480

504542

GU4

Ceramic

#4 Screw Holes 11.5mm OC

300mm

PTFE

19

8.8

1000

32700

109851

GU4

Ceramic

#4 Screw Holes 11.4mm OC

155mm

PTFE

20

12.8

1000

32700

109852

GU4

Ceramic

#4 Screw Holes 11.4mm OC

305mm

PTFE

20

12.8

1000

32700

109853

GU4

Ceramic

#4 Screw Holes 11.4mm OC

590mm

PTFE

20

12.8

1000

32720

525857

GU4

Ceramic

#4 Screw Holes 26mm OC

320mm

PTFE

21

8.7

1000

32720

529699

GU4

Ceramic

#4 Screw Holes 26mm OC

960mm

PTFE

21

8.7

1000

PAGE 6-15

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

LAMPHOLDERS

33721
33800

GU5.3, GU10/GZ10, R7s Lampholders

HALOGEN

Type

Reference
Number

Lamp Type

Material

Mounting

Lead
Length

Lead Material

Drawing

Weight

Unit Pcs.

32480

106457

GU5.3

Ceramic

#4 Screw Holes 11.5mm OC

32480

504542

GU5.3

140mm

PTFE

22

8.8

1000

Ceramic

#4 Screw Holes 11.5mm OC

300mm

PTFE

22

9.1

32680

101248

1000

GU5.3

Ceramic

#4 Screw Holes 12mm OC

140mm

PTFE

23

11

32690

500

536856

GU5.3

Ceramic

#4 Screw Holes 12mm OC

140mm

PTFE

23

12

500

33300

109547

GU5.3

LCP

#4 Screw Holes 11.5mm OC

Terminals

N/A

24

2.2

1000

32400

109855

GU5.3

Ceramic

#4 Screw Holes 11.5mm OC

140mm

PTFE

25

8.1

1000

Terminals

N/A

26

7

1000

GU5.3

GU10/GZ10
31000

108979

GU10/GZ10

LCP

#4 Screw Holes 18mm OC

R7s
30543

109450

R7s

Al

#4 Screw Holes 28mm OC

350mm

PTFE

27

16.7

1000

30550

100720

R7s

Al

#4 Screw Holes 28mm OC

350mm

PTFE

27

16.7

1000
1000

30541

108756

R7s

Al

#4 Screw Holes 28mm OC

320mm

PTFE

27

16.5

32300

100912

R7s

Ceramic

#8 Screw Holes 65mm OC

200mm

PTFE

28

25

400

32310

400036

R7s

Ceramic

#8 Screw Holes 65mm OC

350mm

PTFE

29

72

200

32310

107195

R7s

Ceramic

#8 Screw Holes 65mm OC

200mm

PTFE

29

72

200

32320

400080

R7s

Ceramic

#8 Screw Holes 65mm OC

114mm

PTFE

30

77

200

1

4

5

LAMPHOLDERS

2

6

3

7

PAGE 6-16

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Halogen Lampholders

9

HALOGEN

14

10
15

11
16

12
17

LAMPHOLDERS

13

18

19

PAGE 6-17

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Halogen Lampholders

HALOGEN

20

26

21

22

27

23
28

LAMPHOLDERS

24

29

25

30

PAGE 6-18

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

2G7, 2GX7, 2G8, 2G10, 2G11, G(X)24,
G(X)24 Rotary Lock Lampholders

Type

Reference
Number

Lamp Type

Material

Mounting

35613

500574

2G7

PBT

35610

109235

2G7

35611

109238

35612

109240

CFL

Lead
Orientation

Misc

Drawing

Weight

Unit Pcs.

10 x 20 Snap-In

Horizontal

-

1

18

500

PBT

10 x 20 Snap-In / #4 Screw Holes

Horizontal

-

2

15

500

2G7

PBT

#8 Screw Holes 24mm OC

Horizontal

-

3

17

500

2G7

PBT

#4 Screw Holes for Rear Mount

Horizontal

-

4

14

500

2G7

2GX7
35613

500575

2GX7

PBT

10 x 20 Snap-In

Horizontal

-

1

17

500

35620

109237

2GX7

PBT

10 x 20 Snap-In / #4 Screw Holes

Horizontal

-

2

15

500

35621

109239

2GX7

PBT

#8 Screw Holes 24mm OC

Horizontal

-

3

17

500

35622

109241

2GX7

PBT

#4 Screw Holes for Rear Mount

Horizontal

-

4

14

500

59000

526755

2G8

PBT

#4 Screw Holes

-

-

5

19.6

250

Horizontal

-

6

25.5

250

2G8
2G10
36300

101521

2G10

PBT

#4 Screw Holes 24mm OC

2G11
36051

101489

2G11

PBT

Lateral Pivot Brackets

Horizontal

-

7

14

500

36051

532687

2G11

PBT

Lateral Pivot Brackets

Horizontal

Shunted

7

14

500
500

36050

101485

2G11

PBT

Lateral #8 Screw Holes 24mm OC

Horizontal

-

8

14

36050

532685

2G11

PBT

Lateral #8 Screw Holes 24mm OC

Horizontal

Shunted

8

14

500

36052

101491

2G11

PBT

13.3 x 25.5 Snap-In

Vertical

-

9

14

500

36052

532689

2G11

PBT

13.3 x 25.5 Snap-In

Vertical

Shunted

9

14

500

36053

101493

2G11

PBT

13.3 x 25.5 Snap-In

Horizontal

-

10

14

500

36053

532691

2G11

PBT

13.3 x 25.5 Snap-In

Horizontal

Shunted

10

14

500

G(X)24
71211

527560

G(X)24q-1

PBT

4X #4 Screw Holes 20.6mm OC

Vertical

10/13W

11

12.9

500

71212

527561

G(X)24q-2

PBT

4X #4 Screw Holes 20.6mm OC

Vertical

18W

11

12.9

500

71219

527566

G(X)24q-3/4

PBT

4X #4 Screw Holes 20.6mm OC

Vertical

26/32/42W

11

12.9

500

71215

527564

G(X)24q-5

PBT

4X #4 Screw Holes 20.6mm OC

Vertical

57W

11

13.5

500
500

527565

G(X)24q-6

PBT

4X #4 Screw Holes 20.6mm OC

Vertical

70W

11

13.5

528120

G(X)24q-1

PBT

4.5mm W Split pins spaced 34.5mm

Vertical

10/13W

12

11.9

500

72112

528121

G(X)24q-2

PBT

4.5mm W Split pins spaced 34.5mm

Vertical

18W

12

11.9

500

72119

528126

G(X)24q-3/4

PBT

4.5mm W Split pins spaced 34.5mm

Vertical

26/32/42W

12

11.9

500

72115

528124

G(X)24q-5

PBT

4.5mm W Split pins spaced 34.5mm

Vertical

57W

12

12.5

500
500

72116

528125

G(X)24q-6

PBT

4.5mm W Split pins spaced 34.5mm

Vertical

70W

12

12.5

71311

527589

G(X)24q-1

PBT

10x20 snap-in Foot

Horizontal

10/13W

13

12

500

71312

527590

G(X)24q-2

PBT

10x20 snap-in Foot

Horizontal

18W

13

12

500

71319

527596

G(X)24q-3/4

PBT

10x20 snap-in Foot

Horizontal

26/32/42W

13

12

500

71315

527594

G(X)24q-5

PBT

10x20 snap-in Foot

Horizontal

57W

13

12.6

500
500

71316

527595

G(X)24q-6

PBT

10x20 snap-in Foot

Horizontal

70W

13

12.6

71711

527794

G(X)24q-1

PBT

#8 Screw Holes 24mm OC

Horizontal

10/13W

14

15.2

500

71712

527795

G(X)24q-2

PBT

#8 Screw Holes 24mm OC

Horizontal

18W

14

15.2

500

71719

527800

G(X)24q-3/4

PBT

#8 Screw Holes 24mm OC

Horizontal

26/32/42W

14

15.2

500

71715

527798

G(X)24q-5

PBT

#8 Screw Holes 24mm OC

Horizontal

57W

14

15.8

500

71716

527799

G(X)24q-6

PBT

#8 Screw Holes 24mm OC

Horizontal

70W

14

15.8

500

G(X)24 Rotary Lock
45940

507993

G(X)24q-2

PBT

#4 Screw Holes 28.8mm OC

Vertical

18W

15

20.2

500

45960

507994

G(X)24q-3

PBT

#4 Screw Holes 28.8mm OC

Vertical

26/32W

15

20.2

500

45930

507992

G(X)24q-3/4

PBT

#4 Screw Holes 28.8mm OC

Vertical

26/32/42W

15

20.2

500

45980

507995

G(X)24q-4

PBT

#4 Screw Holes 28.8mm OC

Vertical

42W

15

20.2

500

PAGE 6-19

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

LAMPHOLDERS

71216
72111

CFL Lampholders

CFL

1

6

2
7

3

LAMPHOLDERS

8

4

9

5

PAGE 6-20

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

CFL Lampholders

10

CFL

13

14
11

12
15

LAMPHOLDERS

PAGE 6-21

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Sign Illuminating
Ballasts
A Complete Range Of Solutions…
From The Name You Trust
Universal Lighting Technologies (“Universal”) is known throughout the sign
business as a company that can set and meet today’s toughest industry
standards. Our high-output ballasts are great for rugged outdoor sign
cabinet applications because they provide ultra-reliable, low-temperature
starting as low as -20° F. All Universal sign ballasts offer Class P thermal
protection.
	
•	 Signa® Electronic Sign ballasts are ideal for new sign
		 installations with minimum wire connections, universal input 	
	
voltage, parallel lamp operation, and maximum energy savings.
	
•	 Signa® Electronic Sign ballasts, when paired with our wiring 	
		 blocks, offer the perfect solution for magnetic to electronic sign 	
		 cabinet retrofits.
Universal offers the convenience of one-stop shopping for not just sign
ballasts, but compact fluorescent, linear fluorescent, HID, and all your other
ballast needs.
For the unmistakable sign of quality and reliability, turn to Universal.

Universal Lighting Technologies is a member of the Panasonic Group

Plastic Sign Ballasts

Universal ® sign ballasts provide ultra-reliable low-temperature starting —
plus Class P thermal protection.

Application And Operating Information
Heat

Light Output vs. Temperature

Ballasts generate heat during normal operation. By design,
fluorescent ballasts should operate so that their maximum
hot-spot case temperature does not exceed 80°C (176°F).
Operating at higher temperatures will shorten ballast life
or may cause the thermal protection cicuit to trip.
The temperature the ballast reaches depends on the temperature of the area surrounding it — plus the heat-conducting
surface touching the ballast. Ballasts should be installed in a
manner that avoids future overheating. To maintain normal
ballast temperature, you should:

The light output of a fluorescent lamp varies according to the mercury vapor pressure inside the lamp. This pressure is controlled by
the coldest spot on the bulb wall. The ballast may start the lamp,
but the light output can be very low if the bulb wall temperature
is low. Several factors influence this, including ambient temperatures, wind, type of enclosure, etc. If maximum light output is
critical, consult a lamp manufacturer for advice.

1. Mount the ballast against a flat surface of heavy gauge
metal such as the structural part of the sign.
2. Keep the ballast as far away as possible from other ballasts,
lamps or reflective surfaces. (Lamps generate approximately
three-fourths of the heat in a plastic sign.) The ends of the
lamps are the hottest part, so you should mount the ballast
as far away from the ends as possible.
3. Paint the inside of the sign with flat white paint.

Moisture Protection
1. Vent the sign as well as possible without allowing
water to enter.
2. Ballasts should be mounted horizontally (except for
	 weatherproof types). If the ballast must be mounted
	 vertically, allow room for sufficient air circulation.Wherever 	
	 possible, mount the ballast in an enclosure outside the sign 	
	 by using Universal pup tents. You can get pup tents when 	
	 you order the plastic sign ballast. Your wholesaler will also 	
	 have a supply for your convenience.

Grounding

Plastic Sign Ballasts

The white lead of a ballast must be connected to the neutral
or ground side of the power supply. All metal parts of the sign,
as well as the ballast case, must be grounded either through
the conduit which holds the power supply or by direct connection with a grounding wire. An ungrounded sign is a potential
hazard—and it can give misleading symptoms when looking
for sign faults.

Lamp Starting Problems
Occasionally a field problem will arise involving improper lamp
starting. The usual complaint is that the lamps start slowly (or
not at all). Here are some of the causes:
1. Low line voltage
2. Improper sign grounding
3. Insufficient or no open circuit voltage
4. Dirty lamps during high-humidity operating conditions
5. Lamps improperly inserted in the sockets
If lamp starting is a problem in your installation, check the sign
grounding and open circuit voltage. If both are normal, the
probable cause is dirty lamps. The lamps should be washed
in clean water, drip-dried, and reinstalled. If this doesn’t solve
the problem, contact your nearest Universal representative for
further assistance.

Short Lamp Life
If the lamp has not given proper length of service as specified
by the lamp manufacturer, the following reasons
for early failure should be considered:
1. Frequent starting and short operating periods
2. Improper ballast
3. Improper voltage supply
4. Faulty wiring
5. Defective lamps
6. Lamps improperly inserted in sockets
Early lamp failure will be preceded by a dense blackening on
either or both ends of the lamps. This blackening will extend
three or four inches from the lamp base and should not be
confused with a small dense spot, which is a mercury deposit
that can occur any time during lamp life. Dense blackening
due to early lamp failure should not be confused with the gray
bands that sometimes appear toward the end of normal lamp
life (about two inches from either end of the lamp).­­­­

PAGE 7-2

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Sign Ballast Footage Chart
ELECTRONIC SIGN BALLASTS
No. of Lamps
Per Ballasts

T12HO Lamps
T8HO Lamps

TOTAL FOOTAGE FOR T12HO & T8HO LAMPS
2

4

6

8

10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

ESB-216-12 (Up to 8’ Lamps)

1-2

ESB-216-12 (Up to 6’ Lamps)
ESB-432-14 (Up to 8’ Lamps)

1-4

ESB-432-14 (Up to 6’ Lamps)
ESB-848-46 (Up to 8’ Lamps)

4-6

ESB-848-46 (Up to 6’ Lamps)
ESB-1040-14 (Up to 10’ Lamps)

1-4

ESB-1040-14 (Up to 8’ Lamps)

PLASTIC SIGN BALLAST LEAD LENGTHS (INCHES)

CATALOG NUMBER

WHITE

BLACK

BLUES

REDS

SIGNA ELECTRONIC SIGN BALLASTS - T8 & T12 HIGH OUTPUT LAMPS - 108-35 Volts - 50-60 Hz
SIX LAMP BALLASTS

ESB216-12

24

24

120

120

ESB432-14

24

24

120

120

ESB848-46

24

24

120

120

ESB1040-46

24

24

120

120

Note: Maximum volts above ground, any lead 590 volts.

Plastic Sign Ballasts

PAGE 7-3

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

ELECTRONIC
SIGN
BALLASTS

SIGNA® ELECTRONIC
SIGN BALLASTS

• Instant start for maximum energy savings
• Simplified wiring for fewer connections
• Universal input voltage
• Parallel Lamp Operation

PLASTIC SIGN BALLAST LEAD LENGTHS (INCHES)

TOTAL LAMP
FOOTAGE

CATALOG NUMBER

START
TEMP (ºF)

INPUT
VOLTAGE

MAX. INPUT
VOLTAGE

MAX. LINE
CURRENT (A)

WIRING
DIAGRAM

DIMENSION
CHART REF.

WEIGHT
(LBS.)

1

1

4.2

2

2

7.4

3

3

9.7

2

3

10

T12HO UP TO 8’ IN LENGTH OR T8HO UP TO 6’ IN LENGTH - 120 to 277 Volts - 50/60 Hz
ONE TO TWO LAMP BALLASTS

ESB216-12

2’ min. – 16’ max.

–20

120

134

1.12

277

130

0.47

ONE, TWO, THREE OR FOUR LAMP BALLASTS

ESB432-14

4’ min. – 32’ max.

–20

120

280

2.34

277

274

0.99

FOUR, FIVE OR SIX LAMP BALLASTS

ESB848-46

8’ min. – 48’ max.

–20

120

408

3.41

277

395

1.47

T12HO UP TO 10’ IN LENGTH OR T8HO UP TO 8’ IN LENGTH - 120 to 277 Volts - 50/60 Hz
ONE, TWO, THREE OR FOUR LAMP BALLASTS

ESB1040-14

10’ min. – 40’ max.

–20

120

341

2.85

277

331

1.25

Consult www.signasign.com for complete specification information

Diagram 2

Diagram 1

Diagram 3

ELECTRONIC SIGN BALLASTS
DIMENSION CHART - STANDARD CASE (INCHES)
	Ref. #	

	1	
	2	
	3	

A	

B	

C	

D	

E

10 37/64 ˝	1145/64˝	119/64˝	13/4˝	3 3/16˝
133/16˝	14 5/16˝	13 3/4˝	2 43/64˝	3 3/16˝
15 9/16˝	16 11/16˝	161/8˝	2 43/64˝	3 3/16˝

Diagrams Notes:
When Operating less than the
maximum number of lamps,
insulate unused blue leads.

SIGNA WIRE BLOCK
Electronic Sign Ballasts

For use converting magnetic ballast installations to electronic systems.
CATALOG
NUMBER

MAGNETIC
BALLASTS

NUMBER OF
LAMPS OPERATED

FOR USE WITH:

WB66

6 Lamps

6 Lamps

ESB848-46

WB65

6 Lamps

5 Lamps

ESB848-46

WIDTH

3.00 in (76.2 mm)

WB64

6 Lamps

4 Lamps

ESB848-46

HEIGHT

0.75 in (19.05 mm)

WB44

4 Lamps

4 Lamps

ESB432-14 / ESB1040-14

WEIGHT

0.06 lbs.

PHYSICAL PROPERTIES
LENGTH

6.00 in (152.4 mm)

WBEXT – 24” wiring harness for extending magnetic ballast leads.

PAGE 7-4

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Notes

Plastic Sign Ballasts

PAGE 7-5

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Glossary
ANSI (American National Standards Institute): Non-profit organization
that generates voluntary product performance standards for many U.S.
industries. ANSI Standard C82.11 applies to high frequency fluorescent
lamp ballasts.

Harmonic: An integral multiple of the fundamental frequency (60 Hz)
that becomes a component of the current (see “Harmonic Distortion”).

Arc: Intense luminous discharge formed by the passage of electric
current across a space between electrodes.

Harmonic Distortion: Distortion of an AC waveform caused by multiples
of the fundamental frequency (harmonics). Odd triplet harmonics (thirds,
ninths, etc.) may result in large currents on the neutral line in a four-wire
Wye three-phase system.

Auto Reset Shutdown Circuit: Circuit senses lamp end of life and will
automatically shut off power to the lamp(s). When a new lamp is inserted
in the socket, the ballast resets, and turns on the lamp automatically.

High Efficiency (Energy Saving) Electromagnetic Ballast: Ballast
with Core & Coils, designed to minimize ballast losses compared to
the “standard” ballast.

Ballast Efficacy Factor (BEF): Value used to evaluate various lighting
systems based on light output and power input. The BEF can only be
used to compare systems operating the same type and quantity of lamps.

High Intensity Discharge (HID) Lamp: A lamp containing a filled arc
tube in which the active element becomes vaporized (a gaseous state)
and is discharged into the arc stream to produce light.

Ballast Factor (BF): Measure of light output from lamp operated by
commercial ballast as compared to a laboratory standard reference
ballast. Ballast factor .94 means ballast produces 94% of light
produced by ANSI C82.2 reference ballast operating same lamps.

High Power Factor: A ballast whose power factor is corrected to
90% or greater.

Ballast Luminous Efficiency (BLE): New ballast efficiency metric
introduced by DOE. Equal to the ratio of total lamp arc power to ballast
input power.

Incandescent Lamp: Lamp in which light is produced by a filament
heated by an electric current.
Input Voltage: Power supply voltage required for proper operation of
an arc discharge lighting ballast.

Canadian Energy Standards: Indicates ballast complies with 	
Canadian Energy Standards and meets the requirements of
CAN/CSA-C654-M91.

Instant Start (IS): Lamp starting method in which lamps are started
by high voltage input with no preheating of lamp filaments. Some
rapid start lamps are designed so that they may be instant started.

Canadian Standards Association (CSA): Association that
generates product performance and safety standards for many 	
Canadian industries.

LED: Light Emitting Diode (LED) is a diode that produces light when
the electrical current flows through it.

Circle E: Designates a ballast meets or exceeds the

E requirements of Public Law 100-357 establishing standards
of efficiency.
Constant Current LED System: System where the driver provides a
constant output current and the modules are designed for that current
rating or higher. Modules are constant current rated and have no
current limiting.
Constant Voltage LED System: System where the driver provides a
constant voltage output and the modules incorporate an integral current
control device to regulate the LED current within the module. Drivers
and modules must both have the same constant voltage rating and
power loading must be compatible.

Efficacy: Lumen output per unit of power supplied to ballast (lumens
per watt).
EMI (Electromagnetic Interference): Electrical interference (noise)
generated by electrical and electronic devices. Levels generated by
high frequency electronic devices are subject to regulation by Federal
Communications Commission (FCC).
Filament Voltage: Voltage applied to the lamp cathode.
Foot Candles: Measure of light level on a surface being illuminated.
Defined as one lumen of light per one square foot of surface area.

LED Module: A single component that includes LEDs,
electrical connections, mounting plate/housing, optical interface,
environmental protection, thermal interface and heat sinking.
Lumens/Watt: A measurement of white light produced by each
output watt.
Parallel Lamp Operation: Refers to ballasts that employ multipleoutput current paths independent of one another, allowing other lamps
operated by the ballast to remain lit should companion lamp(s) fail.
Programmed Rapid Start (also Programmed Start): lamp starting
method which preheats the lamp filaments while not allowing the
lamp to ignite and then applies the open circuit voltage (OCV) to start
the lamp. This type of starting circuit keeps lamp end blackening
to a minimum and improves lamp life performance, especially in
applications where the lamps are frequently switched on and off.
Rapid Start (RS): Lamp starting method in which lamp filaments
are heated while open circuit voltage (OCV) is applied to facilitate
lamp ignition.
Series Lamp Operation: Refers to ballasts that employ a single
current path passing through all lamps operated by the ballast.
If one lamp should fail, companion lamps operated by the same
ballasts will also extinguish or dim.

FOR MORE INFORMATION CALL

PAGE 8-1

1-800-BALLAST
(225-5278)

Glossary

Crest Factor (Lamp Current Crest Factor): Ratio of peak lamp
current to RMS or average lamp operating current.

LED Driver: Similar to the function of a fluorescent ballast.
It regulates output voltage or current for the LED module.

Glossary
Trigger Start: A term used for electromagnetic ballasts which operate
pre-heat start lamps in a rapid start manner. They supply higher filament
voltages to heat the electrodes to start the pre-heat lamps, to simulate
the rapid start system. A grounded reflector close to the lamp, together
with a grounded line circuit, is required to provide a capacitive starting
aid effect between lamps and fixture and assist ionization in the starting
process.
UL (Underwriters’ Laboratories, Inc.): Laboratory that sets safety
standards for building materials, electrical appliances and other products.

Glossary

Watts: Measurement of electrical ability to do work

FOR MORE INFORMATION CALL

PAGE 8-2

1-800-BALLAST
(225-5278)

Index
Catalog

Page #

Catalog

Page #

100305

6-9

109459

6-12

100310

100720

100732

100912

100928

100946

101035

101248

101485

101489

101491

101493

101521

102597

102927

102929

106457

107065

107195

107652

107677

107694

108257

108756

108851

108869

108870

108891

108892

108893

108913

108925

108979

109014

109235

109237

109239

109240

109241

109272

109342

109343

109376

109377

109450

6-11

6-16

6-11

6-15

6-15

6-16

6-19

6-19

6-19

6-19

6-19

6-12

6-15

6-15

6-16

6-11

6-16

6-11

6-11

6-15

6-11

6-16

6-12

6-12

6-12

6-12

6-15

6-11

6-11

6-15

6-16

6-12

6-19

6-19

6-19

6-19

6-19

6-19

6-12

6-6

6-6

6-6

6-6

6-16

109460

109518

109547

109851

109852

109852

109853

109855

109856

11102-45SC-TC

1110-246C-TC

1110-247SC-TC

1110-564C-TC

1110-566C-TC

1110-568C-TC

1111-246C-TC

1111-247SC-TC

1120-251A-TC

11210-236C-TC

11210-239C-TC

11210-242C-TC

11210-277C-TC

11210-490C-TC

11210-506C-TC

11210-539C-TC

11210-554C-TC

11210-606C-TC

12210-236C-TC

12210-237C-TC

12210-239C-TC

12210-241C-TC

12210-261C-TC

12210-261RC-TC

12210-552C-TC

12210-602C-TC

12210-606C-TC

123310W

1233142W

1233154W

1233251W

123335W

188156

188157

188164

188165

188166

6-12

6-12

6-16

6-15

6-15

6-15

6-15

6-15, 6-16

6-15

4-35

4-35

4-35

4-35

4-35

4-35

4-35

4-35

4-35

4-35

4-35

4-35

4-35

4-35

4-35

4-35

4-35

4-35

4-36

4-36

4-36

4-36

4-36

4-36

4-36

4-36

4-36

4-27

Index

109238

6-9

6-16

4-27

4-28

4-27

4-27

5-3

5-3

5-3

5-3

5-3

FOR MORE INFORMATION CALL

PAGE 9-1

1-800-BALLAST
(225-5278)

Index
Catalog

Page #

Catalog

Page #

188167

5-3

400036

6-16

188168

188169

188246

188301

188302

188514

188574

188610

188611

188612

188613

188629

188630

188631

188632

188633

188634

188635

188638

188639

188649

188650

188651

188652

188671

188754

188756

188757

188758

188776

188777

188841

188882

188883

Index

188884

188885

188895

188896

188897

188901

188902

188903

188939

188940

188941

188989

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

5-3

400080

404681

500574

500575

501981

501982

502004

502394

504262

504542

505732

505733

505734

505735

505736

505737

505739

505745

505746

505747

505750

505751

506216

506381

507656

507992

507993

507994

507995

508306

508314

508590

508610

508611

509035

509069

509134

509135

509136

509137

509180

509213

509356

509357

520728

525523

6-16

6-7

6-19

6-19

6-12

6-12

6-15

6-11

6-12

6-15, 6-16

6-9

6-9

6-9

6-9

6-9

6-9

6-9

6-9

6-9

6-9

6-9

6-9

6-11

6-12

6-11

6-19

6-19

6-19

6-19

6-15

6-19

6-9

6-15

6-15

6-15

6-15

6-6

6-6

6-6

6-6

6-6

6-11

6-11

6-15

6-15

6-12

FOR MORE INFORMATION CALL

PAGE 9-2

1-800-BALLAST
(225-5278)

Index
Catalog

Page #

Catalog

Page #

525681

6-15

536284

6-5

525681

525750

525857

525857

526018

526211

526246

526251

526755

527560

527561

527564

527565

527566

527589

527590

527594

527595

527596

527794

527795

527798

527799

527800

528120

528121

528124

528125

528126

529699

529773

529773

530250

532685

532687

532689

534050

534101

534102

534105

534132

534218

534219

534636

535782

6-15

6-15

6-11

6-11

6-11

6-11

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-19

6-15

6-11

6-11

6-15

6-19

6-19

6-19

6-19

6-11

6-11

6-11

6-11

6-15

6-11

6-11

6-11

6-11

536293

536294

536297

536298

536300

536301

536303

536304

536306

536307

536309

536310

536312

536313

536315

536316

536320

536322

536325

536328

536329

536330

536336

536337

536338

536344

536346

536347

536348

536349

536350

536368

536369

536370

536372

536373

536469

536822

536856

536857

536857

537049

537057

537132

537138

537141

6-5

6-5

6-5

6-5

6-5

6-5

6-5

6-5

6-5

6-5

6-5

6-5

6-5

6-5

6-5

6-5

6-5

6-5

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

Index

532691

6-15

6-11

6-11

6-16

6-15

6-15

6-11

6-11

6-5

6-5

6-5

FOR MORE INFORMATION CALL

PAGE 9-3

1-800-BALLAST
(225-5278)

Index
Catalog

Page #

Catalog

Page #

537147

6-5

005-1418-BH

4-4

537150

537155

537165

537166

537173

537174

537175

537181

537182

537183

537205

537206

537207

537454

537784

538286

538630

538634

542157

542304

543153

543963

545840

545842

545845

545849

545858

545862

545894

545896

545933

545935

545937

545939

Index

547807

547808

001-2009

005-1184-BH

005-1185-BH

005-1401-BH

005-1410-BH

005-1411-BH

005-1413-BH

005-1414-BH

005-1415-BH

005-1417-BH

6-5

6-5

6-5, 6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-7

6-11

6-11

6-15

6-11

6-11

6-11

6-11

6-11

6-11

6-6

6-6

6-6

6-6

6-6

6-6

6-9

6-9

6-9

6-9

6-9

6-9

6-11

6-11

4-37

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

005-1421-BH

005-1422-BH

005-1464-BH

005-1466-BH

005-1467-BH

005-1468-BH

005-1474-BH

005-1475-BH

005-1495-BH

005-1561-BH

005-1594-BH

005-1799-BH

005-1884-BH

005-1886-BH

005-1887-BH

005-1888-BH

005-1893-BH

005-2167-BH

005-2351-BH

005-2669-BH

005-2776-BH

005-2779-BH

005-2793-BH

005-3160-BH

005-3278-BH

493B2

B114PUNV70-D

B114PUNVDV3-D

B114PUNVSV3-D

B128PUNV50-D

B128PUNV60-D

B128PUNV70-D

B128PUNVDV3-D

B128PUNVSV3-D

B132I347HP

B132IUNVHE-N

B132IUNVHP-N

B132PUNVDV3-A

B132PUNVSV3-A

B132R347V5

B135PUNV70-D

B135PUNVDV3-D

B135PUNVSV3-D

B214PU115S50A

B214PUNVDV3-D

B214PUNVSV3-D

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

4-4

1-46

1-36

2-16

2-17

1-36, 1-37

1-36, 1-37

1-36, 1-37

2-16

2-17

1-13, 1-15, 1-19

1-13, 1-15, 1-17, 1-19, 1-24, 1-26, 1-29, 1-32

1-13, 1-15, 1-19, 1-24, 1-26, 1-29, 1-32

2-16

2-17

2-18

1-37

2-16

2-17

2-20

2-16

2-17

FOR MORE INFORMATION CALL

PAGE 9-4

1-800-BALLAST
(225-5278)

Index
Catalog

Page #

Catalog

Page #

B224PUNV-C

1-38, 3-16, 3-17

B232SR277S30

2-19

B228P3DV3PLA

B228P3DV3PLD

B228P3SV3PLA

B228PU115S50D

B228PU95S50D

B228PUDV3PLA

B228PUDV3PLD

B228PUNV-C

B228PUNV-N

B228PUNV115-D

B228PUNV85-D

B228PUNV90-C

B228PUNV95-D

B228PUNVDV3-D

B228PUNVSV3-D

B228PUSV3PLA

B232I120RES-A

B232I120RES-G

B232I347HP-A

B232I347HPL

B232IUNV-C

B232IUNV104-A

B232IUNVEL-N

B232IUNVHEH-A

2-17

B232SR347V5

2-17

B234SR120M-A

2-23

B234SR277M-A

2-20

B239PUNV-D

2-20

B240R220-A

2-17

B254P347-D

2-17

B254P3DV3PLD

1-36, 1-37

B254P3SV3PLD

1-36, 1-37

B254PHRVHB-E

1-9, 1-36, 1-37

B254PUDV3PLD

1-9, 1-36, 1-37

B254PUNV-D

1-9, 1-36, 1-37

B254PUNVHB-D

1-36, 1-37

B254PUNVPL-A

2-16

B254PUNVPLHBA

2-17

B254PUSV3PLD

2-23

B259I347HP

1-13, 1-15, 1-19, 1-20

B259IUNVEL-A

1-13, 1-15, 1-19, 1-20

B259IUNVHE-A

1-13, 1-15, 1-19, 1-20, 1-24, 1-29, 1-32

B259IUNVHP-A

1-13, 1-15, 1-19, 1-20, 1-32

B260I120M-A

1-13, 1-15, 1-19, 1-20, 1-32, 1-42

B260IUNVHP

1-13, 1-15, 1-26, 1-29

1-13, 1-15, 1-19, 1-20, 1-24, 1-26, 1-29

B286PUNVHE-S

B295PUNVHE-S

B232P3DV3PLD

2-17

B332IUNVEL-A

B232P3S50PLA

2-26, 2-27

B332IUNVHE-A

B232P3S50PLHA

2-25

B332IUNVHP-A

B232P3SV3PLA

2-22

B332PUNVEL-A

B232PUDV3PLA

2-17

B332PUNVHE-A

B232PUDV3PLD

2-17

B332PUNVHEH-A

B232PUNVDV3-A

2-16
1-8, 1-14, 1-15, 1-19, 1-21, 1-24, 1-25, 1-26,
1-27, 1-29, 1-30, 1-32
1-8, 1-14, 1-15, 1-19, 1-21, 1-24, 1-25, 1-26,
1-27, 1-29, 1-30, 1-32
1-8, 1-14, 1-15, 1-19, 1-21, 1-24, 1-25, 1-26,
1-27, 1-29, 1-30
2-26, 2-27

B232IUNVHP-N

B232PUNVEL-B
B232PUNVHE-B
B232PUNVHEH-A
B232PUS50PLA

B232PUS50PLHA

2-25

1-42, 1-43

1-38, 3-17

1-43

1-38, 3-18, 3-19

2-17

2-24

1-38, 3-18, 3-19

2-17

1-38, 1-39, 1-40, 3-15, 3-17, 3-18, 3-19

1-38, 1-39, 1-40, 3-15, 3-17, 3-18, 3-19

1-38, 1-39, 1-40, 1-41, 3-15, 3-17, 3-18, 3-19

1-38, 1-39, 1-40, 1-41, 3-15, 3-17, 3-18, 3-19

2-24

1-32, 1-34

1-34

1-34

1-34

1-44, 1-45

1-44, 1-45

1-35

1-46

B332I347HP

1-14, 1-16, 1-20, 1-21, 1-32, 3-17

B332I347HPL

1-14, 1-16, 1-20, 1-21, 1-32

B332IHRVHB-E

B332SR120S30

1-20, 1-21, 1-24, 1-25, 1-26, 1-27, 1-29, 1-30
1-14, 1-16, 1-20, 1-21, 1-24, 1-25, 1-26, 1-27,
1-29, 1-30, 1-32
1-14, 1-16, 1-20, 1-21, 1-24, 1-25, 1-26, 1-27,
1-29, 1-30, 1-32
1-14, 1-16, 1-20, 1-21, 1-24, 1-25, 1-26, 1-27,
1-29, 1-30, 1-32, 1-42
1-8, 1-14, 1-16, 1-21, 1-22, 1-25, 1-27, 1-28,
1-30, 1-32
1-8, 1-14, 1-15, 1-16, 1-21, 1-22, 1-25, 1-27,
1-28, 1-30
1-8, 1-14, 1-15, 1-16, 1-21, 1-22, 1-25, 1-27,
1-28, 1-30
2-19

B332SR120V5

2-18

B332SR277S30

2-19

B332SR277V5

2-18

B432I120RES-A

1-14, 1-16, 1-17, 1-21, 1-22

B432I347HP

B232PUSV3PLA

2-22

B432I347HPL

B232SR120S30

2-19

B432IUNVEL-A

1-14, 1-17, 1-21, 1-22, 1-33

1-14, 1-17, 1-21, 1-22, 1-33
1-14, 1-17, 1-21, 1-22, 1-25, 1-26, 1-30, 1-31,
1-33

FOR MORE INFORMATION CALL

PAGE 9-5

1-800-BALLAST
(225-5278)

Index

B232P3DV3PLA

1-13, 1-15, 1-19, 1-20, 1-24, 1-26, 1-29
1-13, 1-15, 1-17, 1-19, 1-20, 1-24, 1-26, 1-29,
1-32
2-17

2-18

1-42, 1-43

Index
Catalog
B432IUNVHE-A
B432IUNVHP-A
B432PUNVEL-A
B432PUNVHE-A
B432PUNVHEH-E
B432SR277V5

B454PUNV-E

B454PUNVHB-E

B454PUNVPL-E

B454PUNVPLHBE

C140PUNVDV3

C213/347ME

C213UNVDV3ME

C213UNVME

C213UNVSV3ME

C218/347ME

C218UNVDV3ME

C218UNVME

C218UNVSV3ME

C226UNVDV3ME

C226UNVSV3ME

C232PUNVDV3

C240PUNVDV3

C240PUNVHP-B

C240SI120RH

C240SI277RH

C242/347ME

C242PUNVDV3

C2642/347ME

C2642UNVME

C340SI120RH

C340SI277RH

CF1320H2P

Index

CT213UNVME

CT218UNVME

ES1329A

ES1510A

ES1786X

ESB1040-14

ESB216-12

ESB432-14

ESB848-46

HPS10004B

HPS10005A

HPS1503A

Page #
1-14, 1-17, 1-21, 1-22, 1-25, 1-26, 1-27, 1-28,
1-30, 1-31, 1-33
1-14, 1-17, 1-21, 1-22, 1-25, 1-26, 1-27, 1-28,
1-30, 1-31, 1-33, 1-42
1-8, 1-14, 1-17, 1-22, 1-25, 1-26, 1-28, 1-30,
1-31, 1-33
1-8, 1-14, 1-16, 1-17, 1-22, 1-25, 1-26, 1-28,
1-30, 1-31
2-18

1-38, 1-39, 3-18, 3-19

1-38, 1-39, 3-18, 3-19

1-38, 1-39, 1-40, 1-41, 3-18, 3-19

1-38, 1-39, 1-40, 1-41, 3-18, 3-19

2-16

3-2, 3-9, 3-12

2-16

3-2, 3-7, 3-9, 3-12

2-17

3-2, 3-9, 3-12

2-16

3-2

2-17

2-16

2-17

2-16

2-16

3-7, 3-17

3-17

3-17

3-9, 3-10, 3-13, 3-15, 3-16, 3-18

2-16

3-2, 3-9, 3-10, 3-13, 3-15, 3-16

3-2

3-17

3-17

3-9

3-9

3-16

1-15, 1-21

1-13, 1-15, 1-19

1-47

7-4

7-3, 7-4

7-3, 7-4

7-3, 7-4

4-25, 4-30, 4-33, 4-38, 4-39

4-38, 4-39

4-27, 4-33, 4-38, 4-39

Catalog

Page #

HPS15045B

4-38, 4-39

HPS1504A

4-38, 4-39

HPS1505A

4-38, 4-39

HPS1505B

4-38, 4-39

HPS150G01W

4-38, 4-39

HPS4003A

HPS40045B

HPS4004A

HPS400G05W

HPS4501B

HPS4601B

HPS6001B

M1000120AC5M

M1000230AC5M

M100048TAC5M

M1000ML5AC5M

M1000MLTAC5M

M1000TRIAC5M

M10048TLC3M

M100MLTLC30

M100MLTLC3D

M100TRILC3M

M1500230AC5M

M150048TAC5M

M1500MLTAC5M

M1500TRIAC5M

M150277RCEM

M15048TLC3M

M150MLTAC3M

M150MLTLC3D

M150MLTLC3M

M150TRILC3M

M175230AC3M

M17548TAC3M

M175ML5AC3M

M175MLTAC3M

M175TRIAC30

M250230AC3M

M25048TAC3M

M250ML5AC3M

M250ML5AC4M

M250MLTAC3M

M250MLTAC4M

M250TRIAC3M

M250TRIAC4M

4-28, 4-29, 4-33, 4-38, 4-39

4-38, 4-39

4-38, 4-39

4-38, 4-39

4-38, 4-39

4-38, 4-39

4-30, 4-38, 4-39

4-18

4-33

4-12, 4-18

4-12, 4-18

4-12, 4-18

4-15, 4-18

4-13, 4-20

4-20

4-13, 4-20

4-15, 4-20

4-33, 4-34

4-12, 4-18

4-12, 4-18

4-15, 4-18

4-21

4-13, 4-21

4-13, 4-21

4-13, 4-21

4-13, 4-21

4-15, 4-21

4-33

4-12, 4-16

4-12, 4-16

4-12, 4-16

4-15, 4-16

4-33

4-12, 4-16

4-12, 4-16

4-12, 4-17

4-12, 4-16

4-12, 4-17

4-15, 4-16

4-15, 4-17

FOR MORE INFORMATION CALL

PAGE 9-6

1-800-BALLAST
(225-5278)

Index
Catalog

Page #

Catalog

Page #

M35MLTLC3M

4-13, 4-20

P400ML5AC4M

4-24

M35TRILC3M

M400120AC4M

M400230AC4M

M40048TAC4M

M400ML5AC4M

M400MLTAC4M

M400TRIAC40

M400TRIAC4M

M50MLTLC3M

M50TRILC3M

M7048TLC3M

M70MLTLC3D

M70MLTLC3M

M70TRILC3M

P100048TAC5M

P1000ML5AC5M

P1000MLTAC5M

P175277RCEM

P17548TAC3L

P175MLTAC4L

P175TRIAC3M

P20048TAC3L

P200ML5AC3M

P200MLTAC3L

P200TRIAC3M

P25048TAC4L

P250ML5AC4L

P250MLTAC4L

P250TRIAC4M

P320277RCEM

P32048TAC4L

P320ML5AC4L

P320ML5AC4M

P320MLTAC40

P320TRIAC4M

P35048TAC4O

P350ML5AC40

P350ML5AC4L

P350ML5AC4M

P350MLTAC40

P350MLTAC4M

P350TRIAC4M

P40048TAC4L

P40048TAC4M

P400ML5AC4L

4-33

4-12, 4-17

4-12, 4-17

4-12, 4-17

4-17

4-15

4-13, 4-20

4-15, 4-20

4-13, 4-20

4-13, 4-20

4-13, 4-20

4-15, 4-20

4-25

4-13, 4-25

4-13, 4-25

4-21

4-13, 4-21

4-13, 4-21

4-15, 4-21

4-13, 4-22

4-13, 4-22

4-13, 4-22

4-15, 4-22

4-13, 4-22

4-13, 4-22

4-13, 4-22

4-15, 4-22

4-22

4-13, 4-23

4-13, 4-23

4-13, 4-23

4-22

4-15, 4-22

4-23

4-13, 4-23

4-13, 4-23

4-13, 4-23

4-13

4-23

4-13, 4-23

4-15, 4-23

4-13, 4-24

4-24

4-13, 4-24

P400MLTAC4L

P400TRIAC4M

P45048TAC4L

P450ML5AC4L

P450MLTAC4L

P75048TAC5M

P750ML5AC5M

P750MLTAC5M

P750TRIAC5M

P875MLTAC5M

R17058501-BH

R17058503-BH

R17058507-BH

R17058509-BH

R17058511-BH

R17058514-BH

R17058515-BH

R17058517-BH

R17058519-BH

R17058520-BH

R17058522-BH

R17058523-BH

R17058529-BH

R17058530-BH

R17058532-BH

R17058533-BH

R17058535-BH

R17058536-BH

R17058543-BH

R17058553-BH

R17058554

R17058555-BH

R17058557-BH

R17058558-BH

R17058560

R17058562-BH

R17058563-BH

R17058564

R17058565-BH

R17058567-BH

R17058569

R17058571-BH

R17058574-BH

S1000230AC5M

S1000480AC5M

S100048TAC5M

4-13, 4-24

4-15, 4-24

4-13, 4-25

4-13, 4-25

4-13, 4-25

4-13, 4-25

4-13, 4-25

4-13, 4-25

4-15, 4-25

4-13, 4-25

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

4-5

Index

P35048TAC4L

4-15, 4-20

4-17

4-5

4-5

4-5

4-5

4-5

4-5

4-33

4-30

4-14, 4-30
FOR MORE INFORMATION CALL

PAGE 9-7

1-800-BALLAST
(225-5278)

Index
Catalog

Page #

S1000ML5AC5M

4-14, 4-30

S1000TRIAC5M

4-15, 4-30

S1000MLTAC5M
S100120RCEM
S10048TLC3M

S100MLTLC3M
S100TRILC3M

S150120RCEM
S15048TLC3M
S150TRILC3M

S20048TAC4M

S200MLTAC4M
S200TRIAC4M

4-14, 4-27
4-14, 4-27
4-15, 4-27
4-28

4-14, 4-28
4-15, 4-28
4-14, 4-28
4-14, 4-28
4-28

S25048TAC4M

4-14, 4-28

S250TRIAC4M
S35120RCEM

4-33

4-14, 4-28
4-28
4-27

S400230AC4M

4-33

S40048TAC5M

4-14, 4-29

S40048TAC4M

4-14, 4-29

S400ML5AC4M

4-14, 4-29

S400MLTAC4M

4-14, 4-29

S400ML5AC5M
S400MLTAC5M
S400TRIAC4M
S400TRIAC5M

S430MLTAC4M
S50120RCEM

S50MLTLC3M

S600MLTAC5M
S70120RCEM
S70230LC3M

S7048TLC3M

S70MLTLC3M

Index

4-27

4-28

S250MLTAC4M

S70TRILC3M

Page #

4-14, 4-30

S250120AC4M
S250230AC4M

Catalog

4-14, 4-29

4-14, 4-29
4-15, 4-29
4-15, 4-29
4-29
4-27

4-14, 4-27
4-14, 4-30
4-27

4-33, 4-34
4-14, 4-27
4-14, 4-27
4-15, 4-27

FOR MORE INFORMATION CALL

PAGE 9-8

1-800-BALLAST
(225-5278)

Universal Lighting Technologies Limited Warranty
TM

LIMITED WARRANTY. Universal Lighting Technologies, 51 Century Blvd., Suite 230, Nashville, TN 37214-3683, 1-800-BALLAST, (hereinafter called “Universal”)
warrants to the purchaser and first end-user purchaser only, that its lighting products (hereinafter called “Lighting Products”) will be free from defects in material
and workmanship for the specified warranty periods listed below (each hereinafter called a “Warranty Period”). If any Lighting Product does not meet the limited
warranty provided in the preceding sentence and such defect is reported to Universal during the applicable Warranty Period, then the sole obligation of Universal,
and the SOLE AND EXCLUSIVE REMEDY under this limited warranty, shall be limited to the replacement of such non-performing Lighting Product with, at Universal’s
sole discretion, the same type of Lighting Product or a Lighting Product which is substantially similar thereto. Other than with respect to the duration of the
Warranty Period for the items denoted below with a (“*”) or separately agreed to in a written agreement, if any term or condition of this limited warranty conflicts
with any term or condition of contained on any other document, including but not limited to Universal’s Terms and Conditions of Sale or any product specification
sheet, Application and Performance Data Sheet or similar document for any Lighting Product (collectively “Product Specification Sheet”), the terms and conditions of
this limited warranty shall control.
WARRANTY PERIODS. All Warranty Periods are measured beginning from the date of manufacture. Lighting Products not falling within one of the below listed
categories shall have a Warranty Period of 12 months. The applicable Warranty Period for the type of Lighting Products listed below are as follows:

	
TRIAD Electronic Fluorescent Ballasts 	 						up to 60 Months*
	
Universal, Energy Saving Electromagnetic Fluorescent Ballasts	
			36 Months
	
AddressPro, and DaliPro Ballasts							36 Months
	SuperDim, LevelPro & VariPro							60 Months
	
Standard Universal Electromagnetic, Fluorescent & H.I.D. Ballasts 				24 Months
	
Universal Sign Ballasts 								24 Months
	
MAX-3 Series Sign Ballasts 	 							36 Months
					36 Months
	
Basic-12 and Homestar Electronic Ballasts	
	VS Lampholders 									36 Months
	
VS Brand Magnetic IEC, Electronic IEC, Ignitors, Switches and Capacitors 			
36 Months
	Electronic HID 									up to 60 Months*
	LED Drivers									up to 60 Months*
	
LED Modules	
								36 Months**
* With respect to the items denoted above with a (“*”), the duration of the Warranty Period will vary depending on the specific Lighting Product.
The exact Warranty Period for the items denoted with (“*”) shall be provided on the Product Specification Sheet, for such Lighting Product.
** COVERED DEFECTS FOR LED MODULES. For purposes of this limited warranty, a defect in a LED Module shall be defined as one or more individual LEDs dark at initial installation or > greater
than 10% of individual LEDs dark during the Warranty Period. The Warranty Periods are based on 4000hrs/yr operation of the LED Lighting Products in normal operating conditions in compliance
with the written specifications of Universal. Replacement and/or repair of individual LED Modules does not extend this limited warranty beyond the original Warranty Period.

EXCLUSIONS; TESTING. This limited warranty is conditional and excludes (i) Lighting Products which have been abused, altered, improperly or insufficiently
maintained, or improperly operated, (ii) normal wear and tear or normal usage, (iii) any Lighting Product not installed and operated in accordance with the National
Electric Code (NEC), the Standards for Safety of Underwriters Laboratories, Inc. (UL), Standards for the American National Standards Institute (ANSI), in Canada, the
Canadian Standards Association (CSA), or the International Electrotechnical Commission (IEC). This limited warranty is not applicable to and excludes any Lighting
Product which has not been installed and operated in accordance with Universal’s specifications and connection diagrams or Lighting Products which have been
submitted to abnormal operating conditions. This includes, but is not limited to, excessive temperatures as specified in Universal’s published literature. The
conditions for any tests (to be) performed on Lighting Products which are claimed to have not performed in accordance with the terms of this limited warranty shall
be mutually agreed upon in writing and Universal may be represented at any such tests.
DISCLAIMER. TO THE FULLEST EXTENT PERMITTED BY LAW, UNIVERSAL DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR
A PARTICULAR PURPOSE, INFRINGEMENT, AND THOSE ARISING OUT OF PERFORMANCE OR DEALING OR USAGE OF TRADE OR ANY OTHER IMPLIED
WARRANTY WITH RESPECT TO ANY LIGHTING PRODUCT(S). To the fullest extent permitted by law the foregoing limited warranty is exclusive and in lieu of all
other statutory, written or oral warranties and no other warranties of any kind, statutory or otherwise, are given or herein expressed.
LIMITATIONS OF LIABILITY. To the fullest extent permitted by Law, this limited warranty sets forth the exclusive remedy available to any permitted claimant and
under no circumstances, whether as a result of breach of contract, breach of warranty, tort, strict liability or otherwise, will Universal be liable for consequential,
incidental, special or exemplary damages, including, but not limited to, loss of profits, loss of use or damage to any property or equipment, cost of capital, cost of
substitute product, facilities or services, down time costs or claims of claimant’s customers. Universal’s liability for all claims of any kind or for any loss or damages
arising out of, resulting from or concerning any aspect of this limited warranty or from the Lighting Products or services furnished hereunder, shall not exceed the
price of the specific Lighting Product which gives right to the claim. This exclusive limited warranty shall not be deemed to have failed its essential purpose as long
as Universal is willing and able to carry out the terms of this limited warranty.
WARRANTY REPORTING. The obligations of Universal under this limited warranty shall not arise unless Universal is notified in writing of a defect that is
accompanied by a written statement specifying the claim of defect within sixty (60) days after an alleged defect is first known and no later than the expiration of the
applicable Warranty Period. Any warranty claims and the supporting statement shall be sent to Universal’s Warranty department at the address listed below.
REQUIRED PROVISIONS DEEMED INSERTED. Each and every provision of any applicable law, regulation, and/or clause which is required by any applicable law
or regulation to be inserted in this limited warranty shall be deemed to be inserted herein, and this limited warranty shall be read and enforced as though it were
included herein, and if through mistake or otherwise any such provision is not inserted, or is not correctly inserted, then upon the written application of Universal
or any purchaser or first end-user purchaser of the Lighting Products, this limited warranty shall forthwith be automatically amended to make such insertion or
correction.

Email: TES@UNVLT.com
PAGE 10-1

FOR MORE INFORMATION CALL

1-800-BALLAST
(225-5278)

Universal Lighting Technologies
51 Century Blvd., Ste 230
Nashville, TN 37215
General Info: (615) 316-5100
For Technical Engineering Services (TES), application
support and warranty information, call 1-800-BALLAST
Website: www.unvlt.com
email: webmaster@unvlt.com
All specification information is subject to
change without notification. ULTNAV0614

Universal Lighting Technologies is a member of the Panasonic Group



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2014:06:11 13:31:45-05:00
Creator                         : Adobe InDesign CC (Macintosh)
Modify Date                     : 2014:06:11 13:31:45-05:00
Title                           : 
Trapped                         : False
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2014:06:11 13:31:45-05:00
Creator Tool                    : Adobe InDesign CC (Macintosh)
Format                          : application/pdf
Document ID                     : uuid:9102e65a-379b-3c48-af33-ba134d894a3c
Instance ID                     : uuid:80d6b52e-062a-d549-b27d-cc39a25cf25d
Producer                        : Adobe PDF Library 11.0
Page Count                      : 193
EXIF Metadata provided by EXIF.tools

Navigation menu