118604 Catalog
596050-Attachment 596050-Attachment 596050-Attachment 768386 Batch5 unilog cesco-content
118520-Attachment 118520-Attachment 118520-Attachment 014364 Batch10 unilog cesco-content
118604-Catalog 118604-Catalog 118604-Catalog 043168 Batch5 unilog cesco-content
118604-Catalog 118604-Catalog 118604-Catalog 768386 Batch5 unilog cesco-content
596057-Attachment 596057-Attachment 596057-Attachment 768386 Batch7 unilog cesco-content
2014-07-05
: Pdf 118604-Catalog 118604-Catalog 014364 Batch5 unilog
Open the PDF directly: View PDF
.
Page Count: 193
| Download | |
| Open PDF In Browser | View PDF |
Ballast
Navigator
Universal Lighting Technologies is a member of the Panasonic Group
Table of Contents
Fluorescent Electronic Ballasts
Section 1- Page
Product Overview............................................................................................................................................1-2
Application Operation Information.................................................................................................................1-4
Typical Specifications......................................................................................................................................1-7
F17T8.............................................................................................................................................................1-13
F25T8.............................................................................................................................................................1-15
F32T8 (32, 30, 25 & 28 Watt Four Foot Lamps)........................................................................................1-19
F28T8 (32, 30, 25 & 28 Watt Four Foot Lamps)........................................................................................1-29
F40T8.............................................................................................................................................................1-32
F96T8 Slimline..............................................................................................................................................1-34
F96T8HO High Output.................................................................................................................................1-35
T5....................................................................................................................................................................1-36
T5HO..............................................................................................................................................................1-38
T12 .................................................................................................................................................................1-42
T12 Slimline...................................................................................................................................................1-44
T12HO High Output......................................................................................................................................1-46
T2....................................................................................................................................................................1-47
Energy Management Systems
Section 2- Page
--DCL With DEMANDflex
Product Overview............................................................................................................................................2-2
DEMANDflex T8............................................................................................................................................2-3
DEMANDflex T5, T5HO & TT5...................................................................................................................2-6
DEMANDflex T8 Wiring Diagrams..............................................................................................................2-7
DCL Controls...................................................................................................................................................2-8
FOR MORE INFORMATION CALL
i
1-800-BALLAST
(225-5278)
Table of Contents
Controllable Lighting
Section 2- Page
--Fluorescent Energy Management/Dimming Ballasts and Controls
Product Overview..........................................................................................................................................2-10
-- BallaSTAR Light Level Switching.........................................................................................................2-10
-- SuperDim Analog Dimming...................................................................................................................2-11
-- DaliPRO Digital Dimming......................................................................................................................2-12
-- VariPRO Parallel-Lamp Dimming.........................................................................................................2-13
-- LevelPRO Parallel-Lamp Dimming.......................................................................................................2-13
Application Operation Information...............................................................................................................2-14
Controls for Analog Dimming Ballasts........................................................................................................2-15
DaliPRO.........................................................................................................................................................2-16
DaliPRO Premium.........................................................................................................................................2-17
SuperDim.......................................................................................................................................................2-18
BallaSTAR 0-10 Volt....................................................................................................................................2-19
BallaSTAR Light Level Switching...............................................................................................................2-20
Dimensions & Wiring Diagrams..................................................................................................................2-22
VariPRO.........................................................................................................................................................2-23
LevelPRO.......................................................................................................................................................2-26
Table of Contents
Compact Fluorescent Ballasts
Section 3- Page
Product Overview............................................................................................................................................3-2
Understanding Compact Fluorescent Technology.........................................................................................3-3
Configurations..................................................................................................................................................3-4
Lamp Matrix....................................................................................................................................................3-5
Typical Specifications......................................................................................................................................3-6
Nomenclature...................................................................................................................................................3-7
13-26 Watt Twin, Quad and Triple.................................................................................................................3-9
32 to 70 Watt Triple and Multiple................................................................................................................3-10
2D...................................................................................................................................................................3-12
T5 Circular.....................................................................................................................................................3-15
Long Twin T5................................................................................................................................................3-16
High Intensity Discharge (HID) Ballasts
Section 4- Page
Product Overview............................................................................................................................................4-2
Oil Filled Capacitors........................................................................................................................................4-4
Dry Capacitors.................................................................................................................................................4-5
Bracket Reference Chart..................................................................................................................................4-6
Application and Operation Information..........................................................................................................4-7
Nomenclature.................................................................................................................................................4-10
Typical Specifications....................................................................................................................................4-11
Distributor Replacement Kits........................................................................................................................4-12
Core and Coil
Metal Halide ........................................................................................................................................4-16
Pulse Start Metal Halide......................................................................................................................4-20
High Pressure Sodium..........................................................................................................................4-27
50 Hz Core and Coil Ballasts........................................................................................................................4-33
F-Can Ballast..................................................................................................................................................4-37
Ignitors............................................................................................................................................................4-38
Reference Drawings.............................................................................................................................4-40
Table of Contents
Electronic High Intensity Discharge (eHID) Ballasts
Section 5- Page
Product Overview............................................................................................................................................5-2
Product Family Chart.......................................................................................................................................5-3
Wiring Diagrams..............................................................................................................................................5-4
Dimensions.......................................................................................................................................................5-5
Application and Operation Information..........................................................................................................5-8
Lampholders
Section 6- Page
Application and Operation Information..........................................................................................................6-2
T8 & T12..........................................................................................................................................................6-5
T5......................................................................................................................................................................6-9
HID.................................................................................................................................................................6-11
Halogen..........................................................................................................................................................6-15
CFL.................................................................................................................................................................6-19
Sign Ballasts
Section 7- Page
Application and Operation Information..........................................................................................................7-2
Sign Ballast Footage Chart & Lead Lengths..................................................................................................7-3
Electronic Sign Ballasts...................................................................................................................................7-4
FOR MORE INFORMATION CALL
ii
1-800-BALLAST
(225-5278)
Table of Contents
Glossary
Section 8- Page
..........................................................................................................................................................................8-1
Index
Section 9- Page
..........................................................................................................................................................................9-1
Warranty
Section 10- Page
........................................................................................................................................................................10-1
Table of Contents
FOR MORE INFORMATION CALL
iii
1-800-BALLAST
(225-5278)
Electronic
Fluorescent Ballasts
A Complete Range of Solutions
— From The Name You Trust
For more than 30 years, the lighting industry has relied on
our TRIAD® brand for the most specified, most installed,
most reliable electronic ballasts in the business.
The TRIAD® line offers advantages like installer-friendly
universal input voltage, which ensures that you have the
right voltage ballast every time, and maximum energy
savings for long cycle operations.
And our ULTim8® and AccuStart™ ballasts feature high
efficiency designs and programmed start technology that
dramatically enhances lamp life.
Universal Lighting Technologies is a member of the Panasonic Group
Fluorescent-Electronic
Fluorescent-Electronic
Universal is the leader in energy saving electronic ballasts.
Product Overview
Setting The Pace In T8 Technology
Universal Lighting keeps pushing the frontier of T8 technology with innovative products that deliver
dramatic energy savings, greater fixture design flexibility, longer lamp life and installation ease. You
can count on Universal for some of the industry’s highest efficiency and most hassle-free T8 ballasts.
Universal offers high efficiency T8 ballasts for Instant Start and Programmed Start applications. These
ballasts deliver up to 6% additional energy savings over standard electronic ballasts, even more when
used with the new F32T8/ES (25 Watt), F32T8/ES (30 Watt) or F28T8 (28 Watt) lamps. Our T8 ballasts
are CEE and NEMA Premium compliant.
TRIAD® and ULTim8 Instant Start Applications
Instant Start technology for continuous operation and installer friendly Universal input voltage.
Maximizes energy savings for long cycle operations.
- Some of the most efficient ballasts in the industry for maximum energy savings.
- Available in high efficiency HE normal (.88), EL low (.77), and HEH high (1.18) ballast factor versions.
- Independent lamp operation simplifies troubleshooting. Lamps stay lit if one lamp fails preventing
fixtures from going dark and replacing lamps unnecessarily.
- Lamp will auto-restrike as a standard feature allowing replacement of lamps without recycling power.
- Anti-striation control for better light quality when using energy saving lamps.
- Universal input voltage, installer friendly.
- Because these ballasts are CEE and NEMA Premium compliant they may qualify for utility incentives.
- Backed by 5 year warranty when operated at 75° C max case temperature.
Fluorescent-Electronic
ULTim8® Programmed Start Applications
Features true parallel lamp operation and fast start time (<700ms) so that if one lamp fails, other lamps stay lit.
“Soft start” technology maintains lamp life, making these the perfect choice for high-cycling applications like
occupancy sensors. Designed for use with 30, 28 and 25 Watt energy saving lamps for even more energy savings.
- Same benefits as Instant Start plus ...
- Available in high efficiency HE normal (.88) and EL low (.71), and HEH (1.18) ballast factor versions.
- Programmed Start ballasts are designed to quickly pre-heat lamp cathodes up to their optimum starting
temperature and ignite the lamps quickly.
- Filament cut out on HE and HEH models for instant start level efficiency.
- The quick ignition results in long lamp life without the typical long delay during turn-on.
- Same 5 year warranty as instant start or 3-year warranty for HEH modules when operated at 90° C case temperature.
High Lumen and High Bay Applications
ULTim8® High Lumen ballasts are the high efficiency high ballast factor choice for high lumen T8 applications.
ULTim8® HB ballasts are designed to provide excellent performance in the high ambient temperature
applications where high bay fluorescent fixtures are installed.
EL Ballasts: Used often when retrofitting existing T12 fixtures with T8 lamps to tune down lamp output.
Application areas include stairwells, hallways, bathrooms and other areas that are lit partially during the day.
They are good for using in low light level areas. Change light levels with ballast factor.
HE Ballasts: Used often in new construction, the high efficiency version of our standard HP product. Used for
frequently switched applications including occupancy sensors and daylight harvesting. They are a good solution
for education, commercial offices and retail.
HEH Ballasts: Used to overdrive lamps. Use these for areas with high light output. They are a great solution for
high bay fixtures including applications for warehouses and manufacturing.
PAGE 1-2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Product Overview
T5 & T5HO Ballasts For Architectural and High Bay Applications
Whether it’s for new construction or a retrofit project, Universal’s T5 and T5HO ballasts, with their smaller size
and high lumen output, have become the dominant player in architectural and high bay applications.
Programmed Start ballasts feature a “soft start” technology that maximizes lamp life, making them the perfect
choice for high cycling applications including those involving occupancy sensors and wall switches.
High Efficiency (AccuStart5®, ULTim5®):
Our high efficiency T5 and T5HO ballasts are ideal for bathrooms, hallways, stairwells, gymnasiums,
classrooms, libraries, corridors, offices, recessed volumetric strips, wraps, wall washing, displays, direct/indirect
lighting, surface mount, cove, under cabinet or task lighting. Common applications include: commercial, retail,
hospitality, restaurants, law offices, medical, institutional, airports, and schools.
The AccuStart5® and ULTim5® lines of linear fluorescent T5 and T5HO ballasts offer broad appeal to the most common applications. Universal input voltage (108-305 volts). T5 ballasts support (1) or (2) 2’ F14T5, 3’ F21T5, 4’ F28T5,
and 5’ F35T5 full wattage and energy saving lamps. T5HO ballasts support (1) or (2) 2’ F24T5HO 3’ F39T5HO and (1) (2)
(3) or (4) 4’ F54T5HO full wattage and energy saving lamps.
High Bay (AccuStart5HB®):
T5HO High Bay ballasts are ideal for new construction and fixture retrofits in gymnasiums, high bay retail stores
and warehouses, manufacturing sites, industrial facilities and similar applications. These High Output ballasts
are well suited for applications where space is at a premium, including slim pendant mounted fixtures, cove and
task lighting. AccuStart5HB ballasts offer a replacement opportunity for traditional HID high bay applications.
Light up the aisles for the forklift operator when lighting is needed. Keep spaces lit when and where needed.
Universal offers the AccuStart5HB® line of linear fluorescent T5HO ballasts for High Bay applications. Ideal
for extreme temperature (90° C Case Warranty). Universal input voltage (108-305 volts) and high range voltage
(347-480 volts). These ballasts support (2) and (4) 117, 119, 120, 182, 184, 229 and 235 watt T5HO ballasts.
Canadian Voltage:
Universal offers Canadian voltage in 347V and high range voltage. These ballasts come in standard efficiency,
high efficiency and High Bay for T5 and T5HO applications.
Fluorescent-Electronic
Family of Universal HP Ballasts.
Flexible Fixture design options for T5 and T5HO lamps.
PAGE 1-3
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
SAFETY
NEC & UL Requirements
Ballast installation presents the possibility of exposure to potentially hazardous voltages and should be performed only by qualified personnel. All installation, inspection and maintenance should be performed only with power to the fixture turned off. Additionally, all fixtures and
ballasts must be installed and operated in compliance with the National Electrical Code, Underwriters Laboratories Inc. (UL) requirements,
and all local applicable codes and regulations.
Polarity
Polarity refers to the proper connection of ballast lead wires to line wires. To aid you in a correct installation, Universal ballast leads are
color-coded for easy identification. The WHITE ballast lead is to be connected to the neutral (grounded) and the BLACK (or black with
white tracer) lead always to the phase (“hot”) line wire. Systems where neither of the line wires are at ground potential require specially
designed ballasts. A change in polarity may result in the voltage from the lead to the ground exceeding UL-specified limits. In some types of
ballasts, a change in polarity may decrease voltage from the lead to the ground, thereby impeding the starting dependability of the ballast.
Grounding
Ballast cases and fixtures must always be grounded. The ballast case may be grounded to the fixture or otherwise grounded. It could be
hazardous to make contact with an ungrounded fixture or ballast when in operation. Neglecting to properly ground the ballast and fixture
combination may also result in failure of certain lamps to start or for unacceptable levels of electromagnetic noise to be conducted onto the
power lines.
Operating Line Voltage Limits
To receive the full benefits of rated lamp output and to prolong ballast life, it is essential that voltage supplied to an installation be maintained within limits prescribed for each circuit. These limits are listed below:
Nominal Voltage
120
220
277
347
120-277 (UNV)
347-480 (HRV)
VOLTAGE RANGE
Minimum
Maximum
108
198
249
312
108
312
132
242
305
382
305
528
Fluorescent-Electronic
Subjecting a ballast to excessive voltage for an extended period results in the deterioration of the insulation. This insulation breakdown will
cause early ballast failure. Low voltage has no damaging effect on the ballast. However, lamps may not start reliably, and early lamp failure
could result.
Internal Ballast Protection
Class P Classification - Since January 1, 1984, the National Electrical Code requires that “where Fluorescent fixtures are installed indoors,
the ballast shall have thermal protection integral within the ballast except for simple reactance ballasts.” This ruling applies to replacement
ballasts as well as to those contained within new fixtures.
In compliance with the National Electrical Code, UL has established a Class P ballast classification for fluorescent light fixtures.
A Class P ballast must employ internal thermal protection limiting its operating temperature.
Universal UL-approved Class P ballasts comply with the National Electrical Code requirement and are equipped with an automatic resetting
thermal protector, built-in and adjacent to the transformer coils. The resetting thermal protector functions as a thermostat which will open
and temporarily deactivate the ballast when it exceeds the permissible temperature. It will reset when the ballast cools to a safe operating
temperature. The ballast will continue to cycle until the cause of overheating is eliminated. If the ballast is defective, it must be replaced. If
the cause is external, a Class P ballast will resume normal operation after abnormal conditions are eliminated.
PAGE 1-4
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
SAFETY
Dimming Ballasts - Ballastar® Dimming Ballasts are controlled by using 10-0vDC. Care should be taken to insure that the line voltage
(AC) wires are not connected to the low voltage DC wires. Ballastar® Electronic Dimming Ballasts have protection (safety) circuitry,
that will sense the error so as not to harm the installer or the ballast. Dimming ballasts manufactured after May 1999 have the protection circuit. Dimming ballasts manufactured before this date do not have low voltage circuit protection.
Fusing - Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts. For
a comprehensive list of appropriate fuses, contact our Technical Engineering Services (TES) Department at 1-800-BALLAST
or check out our TES home page at www.unvlt.com.
Grounding - ANSI C82.1 recommends all fixtures and ballasts be grounded. Universal requires all electronic ballasts be grounded.
Thermal Protection - All Universal electronic ballasts meet UL 935 Standard for thermal protection. These ballasts are designated
Class P. A Class P ballast will disconnect the ballast from input power in the event of internal over-temperature.
PERFORMANCE
Lamp Connections
Fluorescent ballasts are designed to generate voltages in excess of 300 volts. It is imperative that proper connection to quality
Lampholders be assured in accordance with wiring diagrams on each page of the catalog and on product labels. Some applications
may not require the use of all of the ballast output leads. If any leads are not to be connected, each should be individually capped
and insulated to at least 600 volts.
Application Versatility
Many Universal models are designed to allow for applications with different types or quantities of lamps. Lamp applications not listed on
label cannot be warranted.
Audible Noise (Sound)
Electrical equipment, including most fluorescent lamp ballasts, produces some noise. Care must be taken to select a ballast with the proper
sound rating for a particular lighting installation. Secure mounting can reduce the potential for audible noise.
EMI/RFI
Electronic ballasts operate at high frequency and, therefore, may produce radio frequency interference (RFI) or electromagnetic
interference (EMI). Some sensitive electrical equipment such as televisions, radios, or some medical equipment can be adversely
affected by this RFI or EMI interference. Currently the electronic frequencies from 450 kilohertz (kHz) to 300 megahertz (MHz) are
regulated by the FCC. For electronic ballasts, the limits and regulations are listed in the Code of Federal Regulations, Title 47, Part 18,
Subpart C titled RF Lighting Devices. ULT provides ballasts compliant with non-consumer limits for commercial applications,
as well as several models in compliance with consumer limits for residential use.
See the Data Sheets for the electronic ballast of interest to determine which FCC requirement, consumer or non-consumer
the particular product meets.
Remote Mounting
Excessive hot or cold temperatures, audible noise requirements, or a desire to operate lamps in more than one fixture with the same ballast
(tandem), may make it desirable to mount the ballast remotely. Care must be taken to allow for ballast heat dissipation and proper grounding.
Lead lengths in excess of those noted cause loading effects that can dramatically impact ballast performance and void the warranty.
See individual data sheets to determine all wiring options.
PAGE 1-5
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
In any application, the wire used to extend leads must be at least as large as the wire supplied on the ballast (18 AWG) with an insulation
rating of 1000 VAC at 90°C.
Application And Operating Information
PERFORMANCE
• Lamp Starting Dependability
Fluorescent lamps are inherently more difficult to start at low temperatures. All ballasts have limitations
as to their ability to start lamps at low ambient temperatures. In this catalog, the low starting point for
each lamp/ballast combination appears in the column marked “Minimum Starting Temperature.”
Universal four lamp instant start ballasts can operate at a minimum starting temperature down to -18°C (0°F)
under the following conditions:
1. Lead lengths to the lamps are those supplied, by Universal, with the ballast or shorter.
2. The distance from the lamp to the ground plane is no greater than 3/4”.
3. The line voltage supplied to the ballast is no less than rated nominal.
4. The ballast or lamps are not remotely mounted.
5. The lamps have been burned in per lamp manufacturer requirements (typically 100 hours).
The lamp manufacturer should be contacted for lamp operating characteristics and requirements below 15°C (50°F).
• Light Output
Optimum light output from fluorescent lamps is achieved when the lamp wall is at 100-110°F.
Any substantial excursion (either colder or warmer) will result in a reduction in light output.
• Ballast Life
A fluorescent lamp ballast, like any other electrical device, generates heat during its normal operation.
Ballast temperatures should be kept as low as possible. Maximum dissipation of heat through fixture
design and proper ballast installation will help. Although excessive temperature may not cause the
ballast to fail immediately, it can shorten ballast life. To assure maximum life, the ballast case temperature
should not exceed 75˚C, in a maximum ambient (fixture cavity) of 40˚C.
Causes of ballast overheating:
• Incorrect line voltage or frequency
• Incorrect size, type or number of lamps
• Incorrect wiring
• Poor heat dissipation due to surrounding insulation
• Sealed (Vapor Tight) Fixtures - Unusual heat build-up due to lack of ventilation in
fixtures may cause thermal (on/off) cycling of certain ballasts. Consult Universal for
specific recommendations.
Fluorescent-Electronic
RECOMMENDATIONS...
• Selection of a proper ballast to match the requirements of the lamp,
fixture, voltage and installation.
•
Mounting of ballast within the fixture with as much surface contact
as possible between the ballast and metal portions of the fixture.
Secure mounting will aid in proper heat dissipation and can minimize
the potential for ballast hum.
• The use of heat-conducting dissipators (radiators), if necessary,
which increase surface contact between the ballast and fixture.
• If necessary, locate the ballast in a remote, cooler area outside the fixture.
• Consult Universal for remote mounting recommendations.
• Starting Method Legend
IS = Instant Start
PS = Programmed Start
RS = Rapid Start
PAR-IS = Parallel Instant Start
PAR-PS = Parallel Programmed Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
PAGE 1-6
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Specifications
TYPICAL SPECIFICATIONS
FOR T8 INSTANT START BALLASTS:
– HP (High Performance Normal Ballast Factor)
– EL (High Efficiency Low Ballast Factor)
– HE (High Efficiency Normal Ballast Factor)
– HEH (High Efficiency High Ballast Factor)
• Ballasts shall include 18AWG solid copper leads color coded in compliance with ANSI C82.11-2011.
• Ballasts shall be instant start and provide starting sequence consistent with ANSI standard C82.11-2011.
• Ballasts (1-4 lamps) shall operate as Parallel Circuit, allowing remaining lamp(s) to maintain full light output if one or more lamps fail.
• Ballasts shall operate from 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ± 10% (Voltage & Frequency)
with no damage to the ballasts.
• Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 42 kHz to minimize interference with infrared
control systems.
• Ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage.
• Ballasts shall have a minimum starting temperature of 0°F (-18°C) for the primary lamp application.
• Ballasts shall have a maximum case temperature test point of 75°C printed on the label for easy fixture testing and trouble shooting.
• Ballasts shall support 18’ maximum lead length remote mounting for the primary lamp.
• Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (Radiated).
• Ballasts shall provide transient immunity as recommended by ANSI C82.11-2011.
• Ballasts shall auto-restrike allowing replacement of lamps without cycling power.
• Ballasts shall incorporate Anti-Striation Circuitry for stable operation of reduced wattage lamps.
• Ballasts shall operate lamps with no visible flicker (<3% flicker index).
• Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage.
• Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor and/or CSA certified for both US and Canadian application.
• Ballasts shall meet NEMA Premium/CEE High Performance for high efficiency operation.
• Ballasts shall be quiet Class A sound rating.
• Ballasts shall have a Ballast Factor for the primary lamp application of greater than .77 for EL, .85 for HE and 1.15 for HEH, per ANSI
C82.11-2011.
• Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.
• Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and
ANSI C82.11-2011.
• The ballasts shall not have any PCB’s.
• The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from
date of manufacture.
• Manufacturer shall have been manufacturing electronic ballasts for at least thirty years.
• Ballasts shall be manufactured in an ISO 9001/ISO 9002 certified facility in North America.
• Ballasts shall be Universal Lighting Technologies Bx32IUNVHP-N (x=1or 2) or Bx32IUNVHP-A (x= 3or 4) depending upon the quantity of
lamps per fixture.
PAGE 1-7
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
• Ballasts shall have a Power Factor greater than .98 for primary lamp.
Specifications
TYPICAL SPECIFICATIONS
FOR T8 PROGRAMMED START BALLASTS:
– EL (High Efficiency Low Ballast Factor)
– HE (High Efficiency Normal Ballast Factor)
– HEH (High Efficiency High Ballast Factor)
• Ballasts shall include 18AWG solid copper leads color coded in compliance with ANSI C82.11-2011.
• Ballasts shall be Programmed Start with arc current established in less than 700 milliseconds after power is applied.
• Ballasts (2-4 lamps) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light output if one or more lamps fail.
• Ballasts shall have a minimum Rh/Rc of 4.25 each time the lamps are started.
• Ballasts shall have a maximum ionization current (Glow Current) of 10 milliamps during preheating interval.
• Ballasts shall operate from a 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ± 10% (Voltage & Frequency) with no
damage to the ballasts.
• Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 42 kHz to minimize interference with infrared control
systems.
• EL and HE ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage. In addition, HEH ballasts shall operate
up to a 194°F (90°C) maximum case temperature.
• Ballasts shall have a maximum case temperature test point printed on the label for easy fixture testing and trouble shooting.
• Ballasts shall have a minimum starting temperature of -20°F (-29°C) for the primary lamp application when not remote mounted.
• Ballasts shall support 20’ maximum lead length remote mounting for the primary lamp.
• Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (Radiated).
• Ballasts shall provide transient immunity as recommended by ANSI C82.11-2011.
• Ballasts shall auto-restrike allowing replacement of lamps without cycling power.
• Ballasts shall incorporate Anti-Striation Circuitry for stable operation of reduced wattage lamps.
• Ballasts shall operate lamps with no visible flicker (<3% flicker index).
• Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage.
• Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor and/or CSA certified for both US and Canadian application.
• Ballasts shall meet NEMA Premium/CEE High Performance for high efficiency operation.
• Ballasts shall be quiet Class A sound rating.
Fluorescent-Electronic
• Ballasts shall have a Ballast Factor for the primary lamp application of greater than .71 for EL, .88 for HE, and 1.15 for HEH, per ANSI C82.11-2011.
• Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp application.
• Ballasts shall have a Power Factor greater than 0.98, for the primary lamp application.
• Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer
recommendation and ANSI C82.11-2011.
• The ballasts shall not have any PCB’s.
• The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from date of
manufacture. In addition, HEH models shall carry a three year warranty when operated at 194°F (90°C) maximum case temperature.
• Manufacturer shall have been manufacturing electronic ballasts for at least thirty years.
• Ballasts shall be manufactured in an ISO 9001/ISO 9002 Certified Facility in North America.
• Ballasts shall be RoHS compliant.
• Ballasts shall be Universal Lighting Technologies ULTim8 Programmed Start Product B232PUNVEL-B, B332PUNVEL-A, B432PUNVEL-A,
B232PUNVHE-B, B332PUNVHE-A, B432PUNVHE-A, B232PUNVHEH-A, B332PUNVHEH-A, or B432PUNVHEH-E.
PAGE 1-8
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Specifications
TYPICAL SPECIFICATIONS
FOR T5 & T5HO BALLASTS:
• Ballasts shall include 18AWG solid copper leads color coded in compliance with ANSI C82.11-2011 or shall use wire trap terminals for ease of
installation.
• Ballasts shall be Programmed Start.
• Ballasts shall operate from a 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ± 10% (Voltage & Frequency) with no
damage to the ballasts.
• Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 42 kHz to minimize interference with infrared control
systems.
• Ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage. HB ballasts shall operate up to 194°F (90°C)
maximum case temperature.
• Ballasts shall have a minimum starting temperature of 0°F (-18°C) for the primary lamp application. T5HO ballasts shall have a minimum starting
temperature of -20°F (-29°C) for the primary lamp application when not remote mounted.
• Ballasts shall support 20’ lead length remote mounting for the primary lamp.
• Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (radiated).
• Ballasts shall provide transient immunity recommended by ANSI C82.11-2011.
• Ballasts shall incorporate lamp shutdown circuitry for end of lamp life protection.
• Ballasts shall auto-restrike to allow for re-lamping without the need to cycle power.
• Ballasts shall operate lamps with no visible flicker (<3% flicker index).
• Ballasts shall tolerate sustained open and short circuit output conditions without damage.
• Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and/or CSA certified for both US and Canadian application.
• Ballasts shall be quiet Class A sound rating.
• Ballasts shall have a Ballast Factor for the primary lamp application greater than .95 per ANSI C82.11-2011. Exceptions are ballasts that
specify BF in part number, such as B228PUNV85-D, B228PUNV90-C and B228PUNV115-D.
• Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.
• Ballasts shall have a Power Factor greater than .98 for the primary lamp application.
• Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer
recommendation and ANSI C82.11-2011.
• The ballasts shall not have any PCB’s.
• The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from
date of manufacture. In addition, HB ballasts shall carry a three year warranty at a maximum case temperature of 194°F (90°C).
Fluorescent-Electronic
• Manufacturer shall have been manufacturing electronic ballasts for at least thirty years.
• Ballasts shall be manufactured in an ISO 9001 / ISO 9002 Certified Facility in North America.
• Ballast shall be Universal Lighting Technologies Accustart5.
PAGE 1-9
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Specifications
TYPICAL SPECIFICATIONS
FOR ELECTRONIC COMPACT FLUORESCENT BALLASTS:
• Ballasts shall be constructed of metal housing to meet plenum and construction code requirements while providing maximum heat transfer
without extra grounding wires for extended ballast life.
• Ballasts shall be constructed using dual entry color coded wire trap terminals for wiring accuracy and ease of installation.
• Ballasts shall be Programmed Start.
• Ballasts shall have a minimum Rh/Rc of 4.25 each time the lamps are started.
• Ballasts shall have a maximum ionization current (Glow Current) of 25 milliamps during preheating interval.
• Ballasts shall operate from 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ± 10% (Voltage &
Frequency) with no damage to the ballasts.
• Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 50 kHz to minimize interference with infrared
control systems.
• Ballasts shall have a minimum starting temperature of 0°F (-18°C) for the primary lamp application.
• Ballasts shall tolerate operation in ambient temperatures up to 140°F (55°C) without damage.
• Ballasts shall have a maximum case temperature test point of 75°C printed on the label for easy fixture testing and trouble shooting.
• Ballasts shall support 12’ lead length remote mounting for the primary lamp.
• Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (radiated).
• Ballasts shall provide transient immunity as recommended by ANSI C82.11-2011.
• Ballasts shall incorporate end of lamp life shutdown circuitry for end of lamp life protection.
• Ballasts shall allow for re-lamping without the need to cycle power.
• Ballasts shall operate lamps with no visible flicker (<3% flicker index).
• Ballasts shall tolerate sustained open and short circuit output conditions without damage.
• Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor and/or CSA certified for both US and Canadian application.
• Ballasts shall be UL 935 Type CC rated to reduce arcing caused by loose connections or improper lamp-pin to lampholder contact.
• Ballasts shall be UL 2043 certified for use in plenums and marked on label as “Suitable for Air Handling Spaces”.
• Ballasts shall be quiet Class A sound rating.
• Ballasts shall have a Ballast Factor for primary lamp application greater than .95 per ANSI C82.11-2011.
Fluorescent-Electronic
• Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.
• Ballasts shall have a Power Factor greater than .98 for the primary lamp application.
• Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and
ANSI C82.11-2011.
• The ballasts shall not have any PCB’s.
• The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from
date of manufacture.
• Manufacturer shall have been manufacturing electronic ballasts for at least thirty years.
• Ballasts shall be manufactured in an ISO 9001 / ISO 9002 Certified Facility in North America.
• Ballasts shall be manufactured by Universal Lighting Technologies.
PAGE 1-10
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Notes
Fluorescent-Electronic
Page 1-11
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Electronic Ballast Applications
Remote Mounting
LAMP
LAMP
BALLAST
Ballast output leads
are run through
conduit to fixture
LAMP
FIXTURE
Configuration is applicable to 1, 2 and 4-lamp fixtures as well.
Through Wiring
FIXTURE
LAMP
LAMP
LAMP
Ballast output leads are run through the fixture to each
lamp, NOT through conduit. Minimize lead lengths by
mounting ballast at the center of the fixture when possible.
Configuration is applicable to 2 and 3-lamp fixtures as well.
Tandem Wiring
2-Ballast Configuration
LAMP BALLAST A
LAMP BALLAST A
BALLAST A
LAMP BALLAST B
LAMP BALLAST B
Fluorescent-Electronic
BALLAST B
LAMP BALLAST A
FIXTURE 1
Output leads from
Ballast A and B are
run through conduit
to second fixture
LAMP BALLAST A
FIXTURE 2
1-Ballast Configuration
BALLAST
LAMP
FIXTURE 1
LAMP
Output lead wire
runs through conduit
to second fixture
PAGE 1-12
FIXTURE 2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (1) & (2)
F17T8 LAMP
F17T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
• 1-2 Lamp Applications
* For Residential Use Only
Lamp Manufacturers for applications with Ballast Factor > 1.20
2 Consult Universal for Availability
1 Consult
IS = Instant Start
PS = Programmed Start
RS = Rapid Start
PAR-IS = Parallel Instant Start
STARTING METHOD LEGEND
PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start
PAGE 1-13
See page 1-18 for Dimensions
and Wiring Diagrams
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
SER-IS = Series Instant Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp
Line
Input
Power Ballast
Ballast
Min. F/C
Starting Line
Catalog
Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method
Volts
Number
(Amps) (Watts)
(PF)
(BF)
Factor (BEF) %
Temp Diag. Dim.
F11T8 - One Lamp Application
120 B132IUNVHE-N
0.09
11
> .99 0.90
8.18
< 10 0/-18
3a
-N
1 IS
120 B232IUNVHP-N
0.12
14
> .99 0.90
6.43
< 10 0/-18
3a
-N
F11T8 - Two Lamp Application
120
0.17
20
> .99
3.90
< 10
2 PAR-IS
B232IUNVHP-N
0.78
0/-18 3 -N
277
0.08
21
> .96
3.71
< 15
F15T8 - One Lamp Application
120 B132IUNVHE-N
0.11
14
> .99 0.90
6.43
< 10 0/-18
3a
-N
1 IS
120 B232IUNVHP-N
0.14
16
> .99 1.02
6.38
< 10 0/-18
3a
-N
F15T8 - Two Lamp Application
120
0.21
> .99
3.51
2 PAR-IS
B232IUNVHP-N
25
0.86
< 10
0/-18 3 -N
277
0.09 > .98 3.50
F17T8 - One Lamp Application
120 B232I120RES-A*
0.35
21
> .50 1.08
5.14
< 150 0/-18
3a
-A
120 B232I120RES-G*
0.34
22
> .50 1.08
4.91
< 150 0/-18
3a
-G
347 B132I347HP
0.05
18
> .95 0.92
5.11
< 15 0/-18
1
ST
120
0.17
> .98
B232IUNV-C
20
1.04 5.20
< 10 0/-18
21a
-C
277
0.08
> .95
120
0.12
> .98
1 IS
B132IUNVEL-A2
14
0.78
5.57
< 15 0/-18
1
-A
277
0.06
> .90
120
0.14
> .98
B132IUNVHE-N
16
0.90
5.63
< 10 0/-18
1
-N
277
0.06
> .97
120
0.14 17
5.29
< 10
B132IUNVHP-N
>.96
0.90
0/-18 1 -N
277
0.07
18 5.00
< 15
120
0.17
> .99
B232IUNVHP-N
21
1.07 5.10
< 10
0/-18 3a -N
277
0.08
> .96
120
0.15
> .99
< 10
B132PUNVHP-A2
17
0.91 5.35
0/-18 2 -A
277
0.07
> .96
< 15
1 PS
120
0.23
26
> .99
5.29
B232PUNVHEH-A1
1.38
< 10 -20/-29 30 -A
277
0.11
27
> .94
5.17
347 ES1510A
0.05
18
> .97 0.87
4.83
< 10 0/-18
40 ESA
F17T8 - Two Lamp Applications
120 B232I120RES-G*
0.49
33
> .50 0.94
2.85
< 140 0/-18
3
-G
120 B232I120RES-A*
0.49
32
> .50 0.94
2.94
< 140 0/-18
3
-A
347 B232I347HP-A
0.09
32
> .95 0.92
2.88
< 10 0/-18
3
-A
347 B232I347HPL
0.09
29
> .98 0.79
2.72
< 10 0/-18
3
ST
120
0.30
> .99
B232IUNV104-A
36
1.04
2.78
< 10
0/-18
3
-A
277
0.15
> .88
120
0.27
2 PAR-IS
B232IUNV-C
31
> .98
0.91
2.94
< 10
0/-18
21
-C
277
0.12
120
0.21 25
3.20
B232IUNVEL-A2
> .95
0.80
< 10
0/-18 3 -A
277
0.10 26
3.08
120
TBD TBD
TBD
B232IUNVEL-N2
TBD
TBD
TBD
TBD TBD TBD
277
TBD TBD
TBD
120
0.24
B232IUNVHE-A2
30
> .95 0.90
3.00
< 10 0/-18
3
-A
277
0.12
120
0.26
> .99
B232IUNVHP-N
31
0.89
2.87
< 10
0/-18
3
-N
277
0.11
> .98
120
0.33 41
2.88
B232IUNVHEH-A
> .95 1.18
< 10 -20/-29
3
-A
277
0.15 40
2.95
F17T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
TRIAD® ELECTRONIC BALLASTS
FOR (3) & (4) F17T8 LAMPS
Fluorescent-Electronic
• 3-4 Lamp Applications
Lamp
Line
Input Power Ballast
Ballast
Min. F/C
Starting Line
Catalog
Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method Volts
Number
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
F17T8 - Two Lamp Applications
2 SER-PS 347 ES1329 A
0.11
36
> .97 0.87
2.42
< 10 0/-18
37 ESA
120
.22
26
> .99
2.80
B232PUNVEL-B
0.74
< 10 -20/-29 30
-B
277
.11
25
> .92
2.96
120
.25
B232PUNVHE-B
30
> .90 0.90
3.00
< 10 -20/-29 30
-B
277
.12
120
.35
> .99
2.95
2
PAR-PS
B232PUNVHEH-A
41
1.20
< 10 -20/-29 30
-A
277
.16 > .97 2.93
120
.38
B332PUNVHEH-A1
46
> .98 1.31
2.85
< 10 -20/-29 30
-A
277
.17
F17T8 - Three Lamp Applications
347 B332I347HP
0.14
48
> .98 0.92
1.92
< 10 0/-18
6
ST
347 B332I347HPL
0.12
43
> .99 0.80
1.85
< 10 0/-18
6
ST
120
0.35
42
> .99
1.95
B332IUNVEL-A
0.82
< 10 0/-18
6
-A
3 PAR-IS
277
0.15
41
> .95
2.00
120
0.39
> .99
B332IUNVHE-A
46
0.92
2.00
< 10 0/-18
6
-A
277
0.17
> .97
120
0.38
> .99
B332IUNVHP-A
45
0.92
2.04
< 10 0/-18
6
-A
277
0.18
> .90
120 B432I120RES-A*
0.72
51
> .50 1.00
1.96
< 135 0/-18
7a
-A
120
0.31
> .99
1.99
B332PUNVEL-A
37
.74
< 10 -20/-29
49
-A
277
0.14
> .94
2.01
120
0.37 44
2.05
B332PUNVHE-A
> .90
.91
< 10 -20/-29
49
-A
277
0.16
43
2.14
3 PAR-PS
120
0.49 59
2.02
B332PUNVHEH-A
> .98 1.19
< 10 -20/-29
49
-A
277
0.22
58
2.04
120
0.47
56
> .99
2.04
B432PUNVHEH-E
1.14
< 10 -20/-29
49
-E
277
0.23
58 > .91
1.97
F17T8 - Four Lamp Applications
120 B432I120RES-A*
0.84
61
> .50 0.92
1.51
< 130 0/-18
7a
-A
347 B432I347HP
0.19
62
> .98 0.92
1.48
< 10 0/-18
7a
ST
347 B432I347HPL
0.17
56
> .97 0.82
1.46
< 10 0/-18
7
ST
120
0.44
53
>
.98
1.49
4 PAR-IS
B432IUNVEL-A
0.79
< 10 0/-18
7a
-A
277
0.20
52
> .95
1.52
120
0.49
59
> .98
1.53
B432IUNVHE-A
0.90
< 10 0/-18
7a
-A
277
0.22
58
> .95
1.55
120
0.49
59
> .98
1.53
B432IUNVHP-A
0.90
< 10 0/-18 7a -A
277
0.22
58
> .90
1.55
120
0.42
50
> .99
1.43
B432PUNVEL-A
0.72
< 10 -20/-29
50
-A
277
0.18
49
> .95
1.47
120
0.49 59
1.52
4 PAR-PS
B432PUNVHE-A
> .90 0.89
< 10 -20/-29
50
-A
277
0.22
58
1.54
120
0.65
77
> .99
1.19 1.54
B432PUNVHEH-E
< 10 -20/-29
50
-E
277
0.30
79
> .95 1.20
1.52
* For Residential Use Only
1 Consult Lamp Manufacturers for applications with Ballast Factor > 1.20
PAGE 1-14
See page 1-18 for Dimensions
and Wiring Diagrams
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
• Standard & Low Profile
Designs Featured
FOR (1) & (2) F25T8 LAMP
• Instant & Programmed
Rapid Starting Options
F17T8F25T8
• 1-2 Lamp Applications
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.07
25
> .95 0.90
3.60
< 10 0/-18
1
ST
0.18
> .98
19
0.78 4.11 <10 0/-18 1 -A
0.09
> .90
0.20
> .99
23
0.89 3.87 <10 0/-18 1 -N
0.09
> .98
0.20
24
>.98
0.88
3.67
< 10 0/-18
1
-N
0.09
0.24
> .99
28
1.05
3.75
< 10 0/-18
3a
-N
0.10
> .98
0.43
28
> .50 1.08
3.86
< 150 0/-18
3a
-A
0.43
28
> .50 1.08
3.86
< 150 0/-18
3a
-G
0.08
26
> .98 0.88
3.38
< 10 0/-18
3a
ST
0.24
28
> .98 1.02
3.64
< 10 0/-18
21a
-C
0.11
0.07
24
> .97 0.87
3.63
< 10 0/-18
40
ESA
0.31
>.99
3.70
37
1.36
< 10 -20/-29 30
-A
0.14 >.97
3.67
0.20
> .99
24
0.91
3.79
< 10 0/-18
2
-A
0.09
> .98
0.64
46
> .50 0.92
2.00
< 130 0/-18
3
-A
0.64
46
> .50 0.92
2.00
< 140 0/-18
3
-G
0.13
46
> .95 0.89
1.93
< 10 0/-18
3
-A
0.12
41
> .98 0.75
1.83
< 10 0/-18
3
ST
0.37 45
2.00
> .98
0.90
< 10 0/-18 21 -C
0.16
44
2.05
0.43
51
> .99
1.94
1.04
< 10 0/-18 3 -A
0.20
50
> .93
1.98
0.30 36 0.79 2.19
> .95
< 10 0/-18
3
-A
0.14 37 0.80 2.18
TBD
TBD
TBD
TBD
TBD
TBD
TBD TBD TBD
TBD
TBD
TBD
0.36
44
> .95 0.88
2.00
< 10 0/-18
3
-A
0.16
0.37 44
2.05
> .99
0.90
< 10 0/-18 3 -N
0.16
43
2.09
0.51 61
1.93
> .95 1.18
< 10 20/-29
3
-A
0.22 60
1.97
0.14
49
> .97 0.87
1.78
<10 0/-18
37
ESA
0.30
36
> .99
2.06
0.74
<10 -20/-29 30 -B
0.14
35
> .96
2.12
0.35 42
2.14
> .90
0.90
<10 -20/-29 30 -B
0.16
41
2.18
0.50
60
> .99
1.98
1.18
<10 -20/-29 30 -A
0.22
59
> .98
1.99
0.55 66
1.98
> .98
1.31
<10 -20/-29 30 -A
0.24
65
2.00
* For Residential Use Only
1 Consult lamp manufacturer for applications with ballast factor >1.20
2 Consult Universal for availability
PAGE 1-15
See page 1-18 for Dimensions
and Wiring Diagrams
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F25T8 - One Lamp Applications
347 B132I347HP
120
B132IUNVEL-A
277
120
1
IS
B132IUNVHE-N
277
120
B132IUNVHP-N
277
120
B232IUNVHP-N
277
120 B232I120RES-A*
120 B232I120RES-G*
347 B232I347HPL
120
B232IUNV-C
277
347 ES1510A
120
B232PUNVHEH-A1
1 PS
277
120
B132PUNVHP-A
277
F25T8 - Two Lamp Applications
120 B232I120RES-A*
120 B232I120RES-G*
347 B232I347HP-A
347 B232I347HPL
120
B232IUNV-C
277
120
B232IUNV104-A
2 PAR-IS 277
120
B232IUNVEL-A2
277
120
B232IUNVEL-N2
277
120
B232IUNVHE-A
277
120
B232IUNVHP-N
277
120
B232IUNVHEH-A
277
2 SER-PS 347 ES1329A
120
B232PUNVEL-B
277
120
B232PUNVHE-B
2 PAR-PS 277
120
B232PUNVHEH-A
277
120
B332PUNVHEH-A1
277
F25T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
TRIAD® ELECTRONIC BALLASTS
FOR (3) F25T8 LAMPS
Fluorescent-Electronic
• 3 Lamp Applications
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F25T8 - Three Lamp Applications
120 B432I120RES-A*
347 B332I347HP
347 B332I347HPL
120
3 PAR-IS
B332IUNVEL-A
277
120
B332IUNVHE-A
277
120
B332IUNVHP-A
277
120
B332PUNVEL-A
3
PAR-PS
277
120
B332PUNVHE-A
277
120
B332PUNVHEH-A
277
120
B432PUNVHEH-E
277
* For Residential Use Only
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.96
71
> .50 0.98
1.38
< 130 0/-18
0.20
68
> .99 0.91
1.34
< 10 0/-18
0.17
60
> .99 0.76
1.26
< 10 0/-18
0.49
59
> .99
1.36
0.80
< 10 0/-18
0.22
58
> .97
1.38
0.56
67
> .99
1.34
0.90
< 10 0/-18
0.24
66
> .98
1.36
0.55
66
> .99
1.36
0.90
<10 0/-18
0.25
65
> .90
1.38
0.46
55
> .99
1.34
0.73
<10 -20/-29
0.20
54
> .97
1.36
0.53 63
1.40
> .90
0.89
<10 -20/-29
0.23
62
1.43
0.72 86
1.36
> .98
1.18
<10 -20/-29
0.31
85
1.38
0.69
> .99
1.37
82
1.13
<10 -20/-29
0.31
> .95
1.38
7a
6
6
-A
ST
ST
6
-A
6
-A
6
-A
49
-A
49
-A
49
-A
49
-E
See page 1-18 for Dimensions and Wiring Diagrams
PAGE 1-16
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (3) & (4) F25T8 LAMPS
F25T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
• 3-4 Lamp Applications
* For Residential Use Only
1 Consult Lamp Manufacturers for applications with Ballast Factor > 1.20
PAGE 1-17
See page 1-18 for Dimensions
and Wiring Diagrams
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp
Line
Input Power Ballast
Ballast
Min. F/C
Starting Line
Catalog
Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method Volts
Number
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
F25T8 - Four Lamp Applications
120 B432I120RES-A*
1.13
85
> .50 0.90
1.06
< 130 0/-18
7a
-A
347 B432I347HPL
0.24
83
> .98 0.78
0.94
< 10 0/-18
7
ST
120
0.72
87
> .99
1.02
B432IUNVHP-A
0.89
< 10 0/-18
7a
-A
277
0.32
85
> .95
1.05
4 PAR-IS 347 B432I347HP
0.26
90
> .98 0.90
1.00
< 10 0/-18
7a
ST
120
0.65 78
1.00
B432IUNVEL-A
> .98 0.78
< 10 0/-18
7a
-A
277
0.28 76
1.03
120
0.72
87
> .99
1.02
B432IUNVHE-A
0.89
< 10 0/-18
7a
-A
277
0.31
85
> .98
1.05
120
0.61
73
> .99
0.98
B432PUNVEL-A
0.72
<10 -20/-29 50 -A
277
0.27
72
> .97
1.00
4 PAR-PS
120
0.73 87
1.01
B432PUNVHE-A
> .90
0.88
<10 -20/-29 50 -A
277
0.31 84
1.04
120
0.94
112 > .99
1.06
B432PUNVHEH-E
1.18
<10 -20/-29 50 -E
277
0.91
108 > .95
1.09
F25T8ES (22W) - One Lamp Applications
120
0.16
> .99
B132IUNVHE-N
19
0.89
4.68
<10 60/16 3a -N
277
0.07
> .98
1 IS
120
0.20
>
.99
B232IUNVHP-N
24
1.14
4.74
<10 60/16 3a -N
277
0.09
> .98
F25T8ES (22W) - Two Lamp Applications
0.31 37
2.43
2 IS 120
B232IUNVHP-N
> .99
0.89
<10 60/16 3 -N
277
0.13
36
2.46
F17T8
&
F25T8
TRIAD® ELECTRONIC BALLASTS
FOR F17T8 & F25T8 LAMPS
Overall Dimensions
Draw #
L
ST
-A
-B
-C
-G
-N
ESA
W
9.50”
9.50”
9.50”
14.25”
9.50”
9.50”
9.50”
2.40”
1.70”
1.50”
1.18”
1.18”
1.30”
1.56”
Mounting Dimensions
H
M
X
1.55”
1.18”
1.00”
1.00”
1.00”
1.00”
1.00”
8.89”
8.89”
8.89”
13.75”
8.89”
8.89”
8.88”
1.69”
1.69”
0.88”
------0.78”
ST
-A, -B, -G, ESA, -N
-C
Fluorescent-Electronic
WIRING DIAGRAMS
DIAGRAM 1
Line
Black
White
BALLAST
DIAGRAM 2
DIAGRAM 3
DIAGRAM 3a
Blue
Blue
Blue
Red
LAMP
LAMP
LAMP
For three lamp operation, cap
any blue lead, insulate to 600V
DIAGRAM 7
DIAGRAM 6
DIAGRAM 7a
DIAGRAM 21
DIAGRAM 8
DIAGRAM 21a
DIAGRAM 37
For one lamp operation, individually
cap blue leads, insulate to 600V
DIAGRAM 30
DIAGRAM 40
DIAGRAM 49
DIAGRAM
49
DIAGRAM 5050
DIAGRAM
PAGE 1-18
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (1) F32T8 LAMP
F32T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
• 1 Lamp Applications
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.25
30
> .98 0.88
2.93
< 10 0/-18
1
-N
0.11
0.09
31
> .98 0.88
2.84
< 10 0/-18
1
ST
0.22
> .98
25
0.77
3.08
< 10 0/-18
1
-A
0.11
> .95
0.25
28
> .99
0.87
3.11
< 10 0/-18
1
-N
0.11
0.53
35
> .50 1.06
3.03
< 135 0/-18
3
-A
0.53
36
> .50 1.06
2.94
< 150 0/-18
3
-G
0.09
32
> .98 0.91
2.84
< 10 0/-18
3
ST
0.29
35
> .99
2.99
1.04
< 10 0/-18 3 -N
0.13
34
> .98
3.03
0.11
36
> .95 1.05
2.92
< 10 0/-18
3
-A
0.29
35
> .98 1.02
2.91
< 10 0/-18 22 -C
0.13
0.24
30
> .95 0.95
3.17
< 10 0/-18
3
-A
0.11
0.26 31
2.95
> .95 0.91
< 10 0/-18
3
-N
0.11 30
2.98
0.28
33
> .95 1.05
3.18
< 10 0/-18
3
-A
0.13
0.39 47
2.94
> .95 1.38
< 10 -20/-29
3
-A
0.18 46
3.00
0.26
31
> .99
2.84
0.88
< 10 0/-18
2
-A
0.11
30
> .98
2.93
0.09
31
> .97 0.87
2.81
< 10 0/-18
40
ESA
0.29 35
2.90
> .90
1.01
<10 -20/-29 30 -B
0.13
34
2.98
0.24
29
> .99
2.88
0.83
<10 -20/-29 30 -B
0.12
28
> .93
3.02
0.40
47
> .99
1.34
2.86
<10 -20/-29 30 -A
0.18
* For Residential Use Only
1 Consult Lamp Manufacturers for applications with Ballast Factor > 1.20
2 Consult Universal for availability
IS = Instant Start
PS = Programmed Start
RS = Rapid Start
PAR-IS = Parallel Instant Start
STARTING METHOD LEGEND
PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start
PAGE 1-19
See page 1-23 for Dimensions
and Wiring Diagrams
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
SER-IS = Series Instant Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F32T8 - One Lamp Applications
120
B132IUNVHP-N
277
347 B132I347HP
120
B132IUNVEL-A
277
120
B132IUNVHE-N
277
120 B232I120RES-A*
120 B232I120RES-G*
1
IS
347 B232I347HPL
120
B232IUNVHP-N
277
347 B232I347HP-A
120
B232IUNV-C
277
120
B232IUNVEL-A2
277
120
B232IUNVEL-N
277
120
B232IUNVHE-A
277
120
B232IUNVHEH-A1
277
120
B132PUNVHP-A
277
347 ES1510A
1
PS 120
B232PUNVHE-B
277
120
B232PUNVEL-B
277
120
B232PUNVHEH-A1
277
F32T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
TRIAD® ELECTRONIC BALLASTS
FOR (2) F32T8 LAMPS
Fluorescent-Electronic
• 2 Lamp Applications
Lamp
Line
Input Power Ballast
Ballast
Min. F/C
Starting Line
Catalog
Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method Volts
Number
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
F32T8 - Two Lamp Applications
120 B232I120RES-A*
0.80
56
> .50 0.88
1.57
< 120 0/-18
3
-A
120 B232I120RES-G*
0.80
56
> .50 0.88
1.57
< 130 0/-18
3
-G
347 B232I347HPL
0.14
50
> .99 0.78
1.56
< 10 0/-18
3
ST
120
0.47
B232IUNVHP-N
55
> .99 0.86
1.58
< 10 0/-18
3
-N
277
0.20
347 B232I347HP-A
0.17
58
> .99 0.88
1.52
< 10 0/-18
3
-A
120
0.48 58
1.52
B232IUNV-C
> .98 0.88
< 10 0/-18
21
-C
277
0.20
56
1.57
120
0.54 65
> .99
1.57
B232IUN104-A
1.04
< 10 0/-18
3
-A
277
0.24
64
> .95
1.59
120
0.40
B232IUNVEL-A2
48
> .95 0.77
1.60
< 10 0/-18
3
-A
277
0.17
120
0.42 49
0.77
B232IUNVEL-N
> .95
1.60
< 10 0/-18
3
-N
277
0.18 48 0.76
2 PAR-IS 120
0.45 55
1.58
B232IUNVHE-A
> .95 0.87
< 10 0/-18
3
-A
277
0.20 54
1.61
120
0.62 74
1.59
B232IUNVHEH-A
> .95 1.18
< 10 -20/-29
3
-A
277
0.26 73
1.62
347
0.22
> .97
B332IHRVHB-E1
76
1.22
1.61
< 10 -20/-29 46 -E
480
0.17
> .90
347 B332I347HPL
0.16
56
> .99 0.87
1.55
< 10 0/-18
6
ST
120
0.53
> .99
B332IUNVHP-A
63
0.99 1.57
< 10 0/-18
6
-A
277
0.24
> .95
347 B332I347HP
0.19
66
> .99 0.99
1.50
< 10 0/-18
6
ST
120
0.48
57
> .99
1.56
B332IUNVEL-A
0.89
< 10 0/-18
6
-A
277
0.21
56
> .97
1.59
120
0.53
64
> .99
1.55
B332IUNVHE-A
0.99
< 10 0/-18
6
-A
277
0.23
63
> .98
1.57
* For Residential Use Only
1 Consult Lamp Manufacturers for applications with Ballast Factor > 1.20
2 Consult Universal for availability
PAGE 1-20
See page 1-23 for Dimensions
and Wiring Diagrams
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
F32T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
FOR (2) & (3) F32T8 LAMPS
• 2 & 3 Lamp Applications
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.17
59
> .97 0.87
1.47
<10 0/-18
0.46 55
1.59
> .90
0.88
<10 -20/-29
0.20
54
1.64
0.38
46
> .99
1.56
0.71
<10 -20/-29
0.16
44
> .97
1.60
0.65 77
1.52
> .99
1.17
<10 -20/-29
0.28
76
1.54
0.54 65
1.59
> .90
1.03
<10 -20/-29
0.24
64
1.61
0.44
53
> .99
1.65
0.87
<10 -20/-29
0.20
52
> .96
1.68
0.70 84
1.54
> .99
1.30
<10 -20/-29
0.30
83
1.57
0.32
0.24
0.21
0.71
0.31
0.25
0.61
0.26
0.70
0.30
1.20
0.24
0.77
0.34
0.28
0.67
0.29
0.74
0.32
110
109
75
84
83
88
74
73
83
81
92
83
92
89
92
80
78
89
87
37
ESA
30
-B
30
-B
30
-A
30
-A
30
-A
30
-A
> .98
1.07
1.18
< 10 -20/-29 46
-E
> .95
1.08
> .99 0.79
1.05
< 10 0/-18
6
ST
> .99
1.05
0.88
< 10 0/-18
6
-A
> .98
1.06
> .99 0.88
1.00
< 10 0/-18
6
ST
> .99
1.04
0.77
< 10 0/-18
6
-A
> .98
1.05
> .99
1.05
0.87
< 10 0/-18
6
-A
> .98
1.07
> .50 0.96
1.04
< 130 0/-18
7a
-A
> .98 0.87
1.05
< 10 0/-18
7
ST
> .99
1.02
0.94
< 10 0/-18 7a -A
> .95
1.06
> .98 0.99
1.08
< 10 0/-18
7a
ST
> .99
1.08
0.86
< 10 0/-18
7a
-A
> .98
1.10
> .99
1.06
0.94
< 10 0/-18
7a
-A
> .98
1.08
* For Residential Use Only
1 Consult lamp manufacturers for applications with Ballast Factor > 1.20
2 Consult Universal for Availability
PAGE 1-21
See page 1-23 for Dimensions
and Wiring Diagrams
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp
Starting Line
Catalog
Number
Qty. Method Volts
F32T8 - Two Lamp Applications
2 SER-PS 347 ES1329A
120
B232PUNVHE-B
277
120
B232PUNVEL-B
277
120
B232PUNVHEH-A
277
2 PAR-PS 120 B332PUNVHE-A
277
120
B332PUNVEL-A
277
120
B332PUNVHEH-A1
277
F32T8 - Three Lamp Applications
3 SER-IS 347
B332IHRVHB-E
480
347 B332I347HPL
120
B332IUNVHP-A
277
347 B332I347HP
120
B332IUNVEL-A
277
120
B332IUNVHE-A
3 PAR-IS 277
120 B432I120RES-A*
347 B432I347HPL
120
B432IUNVHP-A
277
347 B432I347HP
120
B432IUNVEL-A
277
120
B432IUNVHE-A
277
F32T8
• Low Profile
Designs Featured
TRIAD® ELECTRONIC BALLASTS
• Instant & Programmed
Rapid Starting Options
FOR (3) & (4) F32T8 LAMPS
Fluorescent-Electronic
• 4 Lamp Applications
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F32T8 - Three Lamp Applications
120
B332PUNVHE-A
277
120
B332PUNVEL-A
277
120
B332PUNVHEH-A
277
3 PAR-PS
120
B432PUNVHE-A
277
120
B432PUNVEL-A
277
120
B432PUNVHEH-E
277
F32T8 - Four Lamp Applications
120 B432I120RES-A*
347 B432I347HPL
120
4 PAR-IS
B432IUNVHP-A
277
347 B432I347HP
120
B432IUNVEL-A
277
120
B432IUNVHE-A
277
120
4 PAR-PS
B432PUNVHE-A
277
120
B432PUNVEL-A
277
120
B432PUNVHEH-E
277
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.70 84
1.05
> .90
0.88
<10 -20/-29
0.30
82
1.07
0.58
70
> .99
1.02
0.71
<10 -20/-29
0.25
69
> .98
1.03
0.93 112
1.03
> .99
1.15
<10 -20/-29
0.40
109
1.06
0.75 90
1.06
> .90
0.95
<10 -20/-29
0.32
87
1.09
0.66
79
> .99
0.97
0.77
<10 -20/-29
0.29
77
> .97
1.00
0.87
103 > .99
1.08
1.12
<10 -20/-29
0.38
102 > .97
1.10
49
-A
49
-A
49
-A
49
-A
49
-A
49
-A
1.40
109 > .50 0.87
0.80
< 130 0/-18
7a
0.29
101 > .99 0.78
0.77
< 10 0/-18
7
0.93
110 > .99
0.80
0.88
< 10 0/-18
7a
0.40
108 > .98
0.81
0.33
114 > .99 0.88
0.77
< 10 0/-18
7a
0.80
97
> .99
0.79
0.77
< 10 0/-18
7a
0.34
96
> .98
0.80
0.91 109
0.80
> .99 0.87
< 10 0/-18
7a
0.38 106
0.82
0.91 109
0.80
> .90
0.87
<10 -20/-29 50
0.39
107
0.82
0.76
91
> .99
0.78
0.71
<10 -20/-29 50
0.33
90
> .98
0.79
1.20
143 > .99
0.81
1.15
<10 -20/-29 50
0.50
141 > .98
0.82
-A
ST
* For Residential Use Only
2 Consult Universal for Availability
IS = Instant Start
PS = Programmed Start
RS = Rapid Start
PAR-IS = Parallel Instant Start
-A
ST
-A
-A
-A
-A
-E
See page 1-23 for Dimensions and Wiring Diagrams
STARTING METHOD LEGEND
PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start
PAGE 1-22
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
SER-IS = Series Instant Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
F32T8
FOR F32T8 LAMPS
Overall Dimensions
Draw #
L
ST 9.50”
-A 9.50”
-B 9.50”
-C 14.25”
-E 16.88”
-G 9.50”
-N 9.50”
ESA 9.50”
W
Mounting Dimensions
H
M
X
2.40” 1.55” 8.89” 1.69”
1.70” 1.18” 8.89” 1.69”
1.50” 1.00” 8.89” 0.88”
1.18” 1.00” 13.75” --1.74” 1.18” 16.28” --1.18” 1.00” 8.89” --1.30” 1.00” 8.89” ---
1.56” 1.00” 8.88” 0.78”
ST
-A, -B, -E, -G ESA, -N
-C
WIRING DIAGRAMS
Line
Black
White
BALLAST
For one lamp operation, individually
cap unused blue lead, insulate to 600V
DIAGRAM 2
Blue
Blue
Blue
Red
Line
Black
White
Yellow
DIAGRAM 3
Blue
BALLAST
Blue
Red
Red
Yellow
LAMP
Fluorescent-Electronic
DIAGRAM 1
LAMP
LAMP
LAMP
LAMP
LAMP
LAMP
For Two Lamp operation,
Insulate one blue lead to 600V
For Three Lamp Operation,
Insulate one blue lead to 600V
For three lamp operation, cap any
blue lead, insulate to 600V
DIAGRAM 6
DIAGRAM 7
DIAGRAM 7a
DIAGRAM 21
DIAGRAM 30
DIAGRAM 22
DIAGRAM 46
DIAGRAM 37
DIAGRAM 40
DIAGRAM 49
DIAGRAM
49
PAGE 1-23
DIAGRAM 50
DIAGRAM 50
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
F32T8ES
30 WATT
• High Performance
Models and Low Profile
Designs
TRIAD® ELECTRONIC BALLASTS
• Instant and Programmed
Rapid Starting Options
FOR (1) & (2) F32T8ES(30 WATT) LAMPS
Fluorescent-Electronic
• 1-2 Lamp Applications
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F32T8ES(30W) - One Lamp Applications
120
277 B132IUNVEL-A
120
1
IS
B132IUNVHE-N
277
120
B132IUNVHP-N
277
347 B232I347HP-A
120
B232IUNVEL-A2
277
120
B232IUNVEL-N
277
120
B232IUNVHE-A
277
120
277 B232IUNVHP-N
120
B232IUNVHEH-A1
277
120
277 B132PUNVHP-A
120
B232PUNVEL-B
1
PS
277
120
B232PUNVHE-B
277
120
B232PUNVHE-B
277
120
B232PUNVHEH-A1
277
F32T8ES(30W) - Two Lamp Applications
347
1
2 SER-IS
480 B332IHRVHB-E
120
277 B332IUNV104-A
120
B232IUNVEL-A2
277
120
B232IUNVEL-N
277
120
B232IUNVHP-N
277
120
2 PAR-IS
B232IUNVHE-A
277
120
B232IUNVHEH-A
277
347 B232I347HP-A
120
277 B332IUNVEL-A
120
277 B332IUNVHE-A
120
277 B332IUNVHP-A
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.22
> .98
25
0.77
3.08
< 10
0.11
> .95
0.24
26
> .99
0.87
3.35
< 10
0.10
0.24
28
> .98
0.88
3.14
< 10
0.10
0.10
34
> .98 1.04
3.06
< 10
0.23
28
>
.95
0.92
3.92
<
10
0.11
0.24
0.89
3.04
29
> .95 0.88
< 10
0.10
3.08
0.25
> .95 1.05
3.28
< 10
0.12 32
0.27
33
> .99 1.02
3.14
< 10
0.12
32
> .98 1.03
3.21
0.37
43
> .95
1.38
3.21
< 10
0.16
0.23
> .99
28
3.14
< 10
0.10
> .98 0.88
0.23
28
> .99
3.01
0.83
<10
0.12
27
> .93
3.12
0.27 32
3.12
> .90
1.01
<10
0.12
30
3.34
0.27 32
3.12
> .90
1.01
<10
0.12
30
3.34
0.38
47
> .98
1.34
2.85
<10
0.17
0.21
> .97
71
1.22
1.72
< 10
0.16
> .90
0.50
> .99
1.72
61
1.04
< 10
0.23
> .94
1.75
0.38
> .95 0.77
1.67
< 10
0.17 46
0.40
1.57
47
> .95
0.75
< 10
0.17
1.60
0.44 53
1.64
> .99
0.86
< 10
0.19 51
1.69
0.42 52
1.67
> .95 0.87
< 10
0.19 51
1.71
0.59 70
1.69
> .95 1.18
< 10
0.25 68
1.74
0.15
53
> .98 0.88
1.66
< 10
0.46
54
> .99
1.65
0.89
< 10
0.20
53
> .98
1.68
0.49
59
> .99
1.68
0.99
< 10
0.21
57
> .97
1.74
0.50
> .99
59
0.99
1.68
< 10
0.22
> .95
1 Consult lamp manufacturers for applications with Ballast Factor > 1.20
2 Consult Universal for availability
PAGE 1-24
60/16 1 -A
60/16
1
-N
60/16 1 -N
60/16
3a
-A
60/16
3a
-A
60/16
3a
-N
60/16
3a
-A
60/16
3a
-N
60/16
3a
-A
60/16
2
-A
60/16 30 -B
60/16 30 -B
60/16 30 -B
60/16 30 -A
60/16
46
-E
60/16
3
-A
60/16
3
-A
60/16
3
-N
60/16
3
-N
60/16
3
-A
60/16
60/16
3
3
-A
-A
60/16
6
-A
60/16
6
-A
60/16
6
-A
See page 1-31 for Dimensions
and Wiring Diagrams
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
F32T8ES
TRIAD® ELECTRONIC BALLASTS
30 WATT
FOR (2)(cont.), (3) & (4) F32T8ES LAMPS
and Wiring Diagrams
PAGE 1-25
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp
Line
Input Power Ballast
Ballast
Min. F/C
Starting Line
Catalog
Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method Volts
Number
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
F32T8ES(30W) - Two Lamp Applications
120
0.36
43
> .99
1.64
B232PUNVEL-B
0.71
<10 60/16 30 -B
277
0.15
42
> .97
1.71
120
0.42 50
1.75
B232PUNVHE-B
> .90
0.88
<10 60/16 30 -B
277
0.18 48
1.82
2 PAR-PS
120
0.61 75
1.68
B232PUNVHEH-A1
> .99
1.26
<10 60/16 30 -A
277
0.26 74
1.70
120
0.41
49
>
.99
1.77
B332PUNVEL-A
0.87
<10 60/16 30 -A
277
0.18
48
> .96
1.82
120
0.50 60
1.72
B332PUNVHE-A
> .90
1.03
<10 60/16 30 -A
277
0.22
59
1.73
120
0.66 82
1.59
B332PUNVHEH-A1
> .99
1.30
<10 60/16 30 -A
277
0.29 81
1.60
F32T8ES(30W) - Three Lamp Applications
347
0.30
102 > .98
1.16
3 SER-IS
B332IHRVHB-E
1.18
< 10 60/16
46
-E
480
0.22
101 > .95
1.17
120
0.58
70
> .99
1.10
B332IUNVEL-A
0.77
< 10 60/16
6
-A
277
0.25
69
> .98
1.12
120
0.65
79
> .99
1.10
B332IUNVHE-A
0.87
< 10 60/16
6
-A
277
0.28
77
> .98
1.13
120
0.66
79
> .99
1.13
3 PAR-IS
B332IUNVHP-A
0.89
< 10 60/16
6
-A
277
0.29
77
> .95
1.16
347 B432I347HP
0.26
88
> .98 0.99
1.13
< 10 60/16
7a
ST
120
0.62
75
> .99
1.15
B432IUNVEL-A
0.86
< 10 60/16
7a
-A
277
0.27
73
> .98
1.18
120
0.70 84
1.14
B432IUNVHE-A
> .98 0.96
< 10 60/16
7a
-A
277
0.30 82
1.17
120
0.72
86
> .98
1.12
B432IUNVHP-A
0.96
< 10 60/16
7a
-A
277
0.32
84
> .95
1.14
120
0.53
64
> .99
1.12
B332PUNVEL-A
0.71
<10 60/16 49 -A
277
0.23
63
> .97
1.13
120
0.89 106
1.08
B332PUNVHEH-A
> .99
1.15
<10 60/16 49 -A
277
0.38 104
1.11
120
0.65 78
1.13
B332PUNVHE-A
> .90
0.88
<10 60/16 49 -A
277
0.28 76
1.15
3 PAR-PS
120
0.60
72
> .99
1.07
B432PUNVEL-A
0.77
<10 60/16 49 -A
277 0.26
71
> .97
1.09
120
0.74 89
1.07
B432PUNVHE-A
> .90
0.95
<10 60/16 49 -A
277
0.31
84
1.13
120
0.84
99
> .99
1.14
B432PUNVHEH-E
1.13
<10 60/16 49 -E
277
0.37
98
> .96
1.15
1 Consult lamp manufacturers for applications with Ballast Factor > 1.20
See page 1-31 for Dimensions
F32T8ES
(30W -25W)
• High Performance
Models and Low Profile
Designs
• 1-2 Lamp Applications
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
Fluorescent-Electronic
TRIAD® ELECTRONIC BALLASTS
F32T8ES(30W) - Four Lamp Applications
347 B432I347HP
120
B432IUNVEL-A
277
4 PAR-IS
120
B432IUNVHE-A
277
120
B432IUNVHP-A
277
120
B432PUNVEL-A
277
4 PAR-PS
120
B432PUNVHE-A
277
120
B432PUNVHEH-E
277
F32T8ES (25W) - One Lamp Applications
120
B132IUNVEL-A
277
120
1 IS
B132IUNVHE-N
277
120
B132IUNVHP-N
277
120
B232IUNVEL-A2
277
120
B232IUNVEL-N
277
120
B232IUNVHE-A
277
120
B232IUNVHP-N
277
120
B232IUNVHEH-A1
277
120
B132PUNVHP-A
277
120
B232PUNVEL-B
277
1
PS
120
B232PUNVHE-B
277
120
B232PUNVHEH-A1
277
F32T8ES (25W) - Two Lamp Applications
347
2 SER-IS
B332IHRVHB-E
480
120
B232IUNV104-A
277
120
2
277 B232IUNVEL-A
120
B232IUNVEL-N
277
120
B232IUNVHE-A
277
120
B232IUNVHP-N
277
2 PAR-IS
120
B232IUNVHEH-A
277
120
B332IUNVEL-A
277
120
B332IUNVHE-A
277
120
B332IUNVHP-A
277
FOR (1) & (2)
F32T8ES (25 WATT) LAMPS
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.31
106 > .99 0.88
0.83
< 10
0.75
91
> .99
0.85
0.77
< 10
0.32
90
> .98
0.86
0.85
103 > .99
0.84
0.87
< 10
0.36
100 > .98
0.87
0.87
104 > .98
0.85
0.88
< 10
0.38
101 > .95
0.87
0.71 85
> .99
0.83
0.71
<10
0.31 84 > .98 0.84
0.86 103
0.84
> .90
0.87
<10
0.37
101
0.86
1.14 135
> .99
0.87
1.18
<10
0.50
134 > .97 0.88
60/16
7a
ST
60/16
7a
-A
60/16
7a
-A
60/16
7a
-A
60/16 50 -A
60/16 50 -A
60/16 50 -E
0.17
> .98
20
0.77
3.85
< 10 60/16
1
0.07
> .95
0.20
23
> .99
0.87
3.78
< 10 60/16
1
0.09
0.20
24
> .98
0.88
3.67
< 10 60/16
1
0.09
0.20
24
> .99
3.96
< 10
0.95
60/16 3a
0.09
25
> .95
3.80
< 15
0.20
> .99 0.84
3.54
< 10
24
60/16 3a
0.09
> .95 0.85
3.55
< 15
0.23
> .98
27
1.05
3.89
< 10 60/16
3a
0.10
> .95
0.22
27
> .99
3.60
0.96
< 10 60/16
3a
0.10
26
> .98
3.64
0.32 38
3.63
> .95 1.38
< 10 60/16
3a
0.14 37
3.73
0.21
25
> .99 0.88
3.52
< 10 60/16
2
0.09
0.20 24
> .99
3.49
0.83
<10 60/16 30
0.11 23 > .92
3.58
0.23 28
3.80
> .90
1.05
<10 60/16 30
0.12
27
3.88
0.33
1.36 3.81
36
> .98
<10 60/16 30
0.14
1.35
3.72
0.18
> .95
61
1.14
1.87
< 10
0.14
> .90
0.42
> .99
1.92
52
1.04
< 10
0.20
> .93
1.82
0.33
39
> .99
1.97
0.77
< 10
0.14
38
> .98
2.03
0.33
39
> .99 0.72
1.83
< 10
0.14
38
> .98 0.71
1.87
0.37 44
1.98
> .98 0.87
< 10
0.16 43
2.02
0.36 43
1.84
> .99
0.78
< 10
0.15 42
1.88
0.49 59
2.00
> .95 1.18
< 10
0.21 58
2.03
0.37
44
> .99
2.02
0.89
< 10
0.16
43
> .95
2.07
0.43
51
> .98
1.94
0.99
< 10
0.19
50
> .95
1.98
0.43
> .98
51
1.00
1.96
< 10
0.20
> .90
1 Consult lamp manufacturers for applications with Ballast Factor > 1.20
PAGE 1-26
-A
-N
-N
-A
-N
-A
-N
-A
-A
-B
-B
-A
60/16
46
-E
60/16
3
-A
60/16
3
-A
60/16
3
-N
60/16
3
-A
60/16
3
-N
60/16
3
-A
60/16
6
-A
60/16
6
-A
60/16
6
-A
See page 1-31 for Dimensions
and Wiring Diagrams
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (3) & (4)
F32T8ES (25 WATT) LAMPS
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
25 WATT
• 3-4 Lamp Applications
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.31 37
> .99
1.91
0.71
<10
0.14
35
> .96 2.03
0.36 43
2.04
> .90
0.88
<10
0.16
41
2.14
0.51 59
2.01
> .98
1.18
<10
0.22 58
2.02
0.35 42
> .99
2.07
0.87
<10
0.16 41 > .95 2.13
0.42 50
2.07
> .90
1.04
<10
0.18
48
2.15
0.57
68
> .98
1.30
1.91
<10
0.25
0.26
88
0.19
0.48
58
0.21
57
0.56
66
0.24
65
0.57
69
0.26
68
0.50
60
0.22
58
0.60
72
0.26
71
0.61
73
0.27
72
> .97
1.11
1.26
< 10
> .90
> .99
1.33
0.77
< 10
> .97
1.35
> .98
1.32
0.87
< 10
> .95
1.34
> .99
1.30
0.90
< 10
> .95
1.32
> .99
1.43
0.86
< 10
> .94
1.48
> .99
1.33
0.96
< 10
> .95
1.35
> .98
1.33
0.97
< 10
> .95
1.35
60/16 30 -B
60/16 30 -B
60/16 30 -A
60/16 30 -A
60/16 30 -A
60/16 30 -A
60/16
46
-E
60/16
6
-A
60/16
6
-A
60/16
6
-A
60/16
7a
-A
60/16
7a
-A
60/16
7a
-A
See page 1-31 for Dimensions
and Wiring Diagrams
PAGE 1-27
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
F32T8ES (25W) - Two Lamp Applications
120
B232PUNVEL-B
277
120
B232PUNVHE-B
277
120
B232PUNVHEH-A
277
2 PAR-PS
120
B332PUNVEL-A
277
120
B332PUNVHE-A
277
120
B332PUNVHEH-A1
277
F32T8ES (25W) - Three Lamp Applications
347
3 SER-IS
B332IHRVHB-E
480
120
B332IUNVEL-A
277
120
B332IUNVHE-A
277
3 PAR-IS 120
B332IUNVHP-A
277
120
B432IUNVEL-A
277
120
B432IUNVHE-A
277
120
B432IUNVHP-A
277
F32T8ES
• High Performance
Models and Low Profile
Designs
F32T8ES
• High Performance
Models and Low Profile
Designs
25 WATT
• 1-2 Lamp Applications
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
Fluorescent-Electronic
TRIAD® ELECTRONIC BALLASTS
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
F32T8ES (25W) - Three Lamp Applications
120
B332PUNVEL-A
277
120
B332PUNVHE-A
277
3 PAR-PS
120
B332PUNVHEH-A
277
120
B432PUNVEL-A
277
120
B432PUNVHE-A
277
120
B432PUNVHEH-E
277
F32T8ES (25W) - Four Lamp Applications
120
B432IUNVEL-A
277
120
B432IUNVHE-A
277
4 PAR-IS
120
B432IUNVHP-A
277
120
B432PUNVEL-A
277
4 PAR-PS
120
B432PUNVHE-A
277
120
B432PUNVHEH-E
277
IS = Instant Start
PS = Programmed Start
RS = Rapid Start
PAR-IS = Parallel Instant Start
FOR (1) & (2)
F32T8ES (25 WATT) LAMPS
0.46 55
> .99
1.30
0.71
<10
0.20 54 > .97 1.32
0.55 66
1.34
> .90
0.88
<10
0.24 65
1.35
0.75 90
1.28
> .98
1.15
<10
0.32
88
1.31
0.52 62
> .99
1.23
0.77
<10
0.23
61
> .96
1.26
0.59 71
> .90
0.95
1.35
<10
0.26
70
0.76 90
> .99
1.26
1.13
<10
0.35
92
> .95 1.23
60/16 49 -A
60/16 49 -A
60/16 49 -A
60/16 49 -A
60/16 49 -A
60/16 49 -E
0.62
75
> .99
1.09
0.82
<10 60/16 7a -A
0.27
73
> .95
1.12
0.73
87
> .99
1.00
0.87
<10 60/16 7a -A
0.31
85
> .98
1.02
0.74
90
> .98
0.99
0.89
< 10 60/16 7a -A
0.33
88
> .95
1.01
0.61
73
> .99
0.97
0.71
<10 60/16 50 -A
0.27
72
> .97
0.98
0.71 85
1.02
> .90
0.87
<10 60/16 50 -A
0.31
84
1.03
1.04
124 > .99
0.96
1.18
<10 60/16 50 -E
0.45
118 > .95
1.00
See page 1-31 for Dimensions
and Wiring Diagrams
STARTING METHOD LEGEND
PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start
PAGE 1-28
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
SER-IS = Series Instant Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (1) & (2) F28T8 LAMPS
• High Performance
Models and Low Profile
Designs
F28T8
• Instant and Programmed
Rapid Starting Options
• 1-2 Lamp Applications
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.20
> .98
21
0.77
3.67
< 10
0.10
> .95
0.20
24
> .99
0.87
3.63
< 10
0.10
0.22
26
> .98
0.88
3.38
< 10
0.10
0.09
32
> .98 1.04
3.25
< 10
0.22 26
3.65
> .95 0.95
< 10
0.10 27
3.52
0.23 27
3.30
> .95 0.88
< 10
0.10 26
3.31
0.24
29
> .95 1.10
3.79
< 10
0.11
0.33 40
3.45
> .95 1.38
< 10
0.15 39
3.54
0.25
30
> .99 0.99
3.36
< 10
0.11
29
> .98 1.00
3.40
0.28
27
> .99 0.88
3.26
< 10
0.11
0.21
25
> .99
3.33
0.83
<10
0.11
24
> .92
3.46
0.25 30
3.41
> .90
1.01
<10
0.12
29
3.45
0.35
3.47
39
> .97
1.35
<10
0.15
3.44
0.19
> .97
65
1.22
1.88
< 10
0.15
> .90
0.14
50
> .98 0.88
1.76
< 10
0.47
56
> .99
1.79
1.04
< 10
0.21
55
> .94
1.82
0.36
43
> .95 0.77
1.79
< 10
0.15
0.36 43
0.75
> .95
1.76
< 10
0.15 42 0.74
0.40 49
1.78
> .95 0.87
< 10
0.18 48
1.81
0.40 48
1.76
> .99
0.83
< 10
0.17 46
1.78
0.53 64
1.84
> .95 1.18
< 10
0.23 62
1.90
0.41
49
> .99
1.82
0.89
< 10
0.18
48
> .95
1.85
0.45
54
> .99
1.83
0.99
< 10
0.19
53
> .97
1.87
0.46
55
> .99
1.80
0.99
< 10
0.21
54
> .90
1.83
1 Consult lamp manufacturers for applications with Ballast Factors > 1.20
2 Consult Universal for availability
PAGE 1-29
60/16
1
-A
60/16
1
-N
60/16
1
-N
60/16
3a
60/16
3a
-A
-A
60/16
3a
-N
60/16
3a
-A
60/16
3a
-A
60/16
3a
-N
60/16
2
-A
60/16 30 -B
60/16 30 -B
60/16 30 -A
60/16
46
-E
60/16
3
-A
60/16
3
-A
60/16
3
-A
60/16
3
-N
60/16
3
-A
60/16
3
-N
60/16
3
-A
60/16
6
-A
60/16
6
-A
60/16
6
-A
See page 1-31 for Dimensions
and Wiring Diagrams
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F28T8 - One Lamp Applications
120
B132IUNVEL-A
277
120
1 IS
B132IUNVHE-N
277
120
B132IUNVHP-N
277
347 B232I347HP-A
120
B232IUNVEL-A2
277
120
B232IUNVEL-N
277
120
B232IUNVHE-A
277
120
B232IUNVHEH-A1
277
120
B232IUNVHP-N
277
120
B132PUNVHP-A
277
120
B232PUNVEL-B
277
1
PS
120
B232PUNVHE-B
277
120
B232PUNVHEH-A1
277
F28T8 - Two Lamp Applications
347
2 SER-IS
B332IHRVHB-E1
480
347 B232I347HP-A
120
B232IUNV104-A
277
120
B232IUNVEL-A2
277
120
B232IUNVEL-N
277
2 PAR-IS
120
B232IUNVHE-A
277
120
B232IUNVHP-N
277
120
B232IUNVHEH-A
277
120
B332IUNVEL-A
277
120
B332IUNVHE-A
277
120
B332IUNVHP-A
277
F28T8
• High Performance
Models and Low Profile
Designs
• Instant and Programmed
Rapid Starting Options
TRIAD® ELECTRONIC BALLASTS
FOR (2)(cont.), (3) & (4) F28T8 LAMPS
Fluorescent-Electronic
• 2-4 Lamp Applications
Lamp
Line
Input Power Ballast
Ballast
Min. F/C
Starting Line
Catalog
Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method Volts
Number
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
F28T8 - Two Lamp Applications
120
0.33 40
> .99
1.79
B232PUNVEL-B
0.71
<10 60/16 30 -B
277
0.15
39
> .96 1.84
120
0.39 46
1.90
B232PUNVHE-B
> .90
0.88
<10 60/16 30 -B
277
0.17
45
1.95
120
0.56 64
1.85
B232PUNVHEH-A
> .99
1.18
<10 60/16 30 -A
277
0.24 63
1.86
2 PAR-PS
120
0.45 54
1.93
B332PUNVHE-A
> .90
1.04
<10 60/16 30 -A
277
0.20
53
1.97
120
0.38 46
>
.99
1.91
B332PUNVEL-A
0.87
<10 60/16 30 -A
277
0.17
45
> .96 1.92
120
0.60 72
1.81
B332PUNHEH-A1
> .98
1.30
<10 60/16 30 -A
277
0.26
71
1.83
F28T8 - Three Lamp Applications
347
0.28
> .97
3 SER-IS
B332IHRVHB-E
94
1.18
1.26
< 10 60/16
46
-E
480
0.21
> .90
120
0.53
66
> .99
1.17
B332IUNVEL-A
0.77
< 10 60/16
6
-A
277
0.23
65
> .97
1.18
120
0.60
75
> .99
1.16
B332IUNVHE-A
0.87
< 10 60/16
6
-A
277
0.26
73
> .98
1.19
120
0.61
73
> .99
1.22
B332IUNVHP-A
0.89
< 10 60/16
6
-A
277
0.27
71
> .95
1.25
3 PAR-IS 347 B432I347HP
0.23
78
> .98 0.99
1.27
< 10 60/16
7a
ST
120
0.57
69
> .99
1.25
B432IUNVEL-A
0.86
< 10 60/16
7a
-A
277
0.26
68
> .95
1.26
120
0.64
77
> .99
1.25
B432IUNVHE-A
0.96
< 10 60/16
7a
-A
277
0.28
75
> .98
1.28
120
0.66
79
> .98 0.97
1.23
B432IUNVHP-A
< 10 60/16
7a
-A
277
0.29
77
> .95 0.97
1.26
120
0.49
59
> .99
1.21
B332PUNVEL-A
0.71
<10 60/16 49 -A
277
0.21
58
> .97
1.22
120
0.59 71
1.25
B332PUNVHE-A
> .90
0.88
<10 60/16 49 -A
277
0.25
68
1.29
120
0.79 94
1.22
B332PUNVHEH-A
> .98
1.15
<10 60/16 49 -A
277
0.34 92
1.25
3 PAR-PS
0.56
67
> .99
1.15
120 B432PUNVEL-A
0.77
<10 60/16 49 -A
277
0.25
66
> .97
1.17
120
0.64 77
1.24
B432PUNVHE-A
> .90
0.95
<10 60/16 49 -A
277
0.28
76
1.25
120
0.76
> .99
B432PUNVHEH-E
90
1.13 1.25
<10 60/16 49 -E
277
0.34
> .96
1 Consult lamp manufacturers for applications with Ballast Factors > 1.20
See page 1-31 for Dimensions
and Wiring Diagrams
PAGE 1-30
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
F28T8
FOR F32T8ES AND F28T8 LAMPS
Overall Dimensions
Draw #
L
ST
-A
-B
-E
-N
9.50”
9.50”
9.50”
16.88”
9.50”
W
2.40”
1.70”
1.50”
1.74”
1.30”
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.28
95
> .98 0.88
0.93
< 10
0.70
85
> .99
0.91
0.77
< 10
0.31
84
> .98
0.92
0.77
97
> .99
0.90
0.87
< 10
0.33
94
> .98
0.93
0.80
96
> .98 0.89
0.93
< 10
0.35
93
> .95 0.88
0.95
0.64 77
> .99
0.92
0.71
<10
0.28
76
> .97 0.93
0.77 92
0.94
> .90
0.87
<10
0.33 90
0.97
1.05
> .99
0.95
125
1.18
<10
0.46
> .98
0.94
60/16
7a
ST
60/16
7a
-A
60/16
7a
-A
60/16
7a
-A
60/16 50 -A
60/16 50 -A
60/16 50 -E
Mounting Dimensions
H
M
X
1.55”
1.18”
1.00”
1.18”
1.00”
8.89”
8.89”
8.89”
16.28”
8.89”
1.69”
1.69”
1.69”
--1.69”
-A, -B, -E, -N
ST
WIRING DIAGRAMS
DIAGRAM 1
Line
Black
White
BALLAST
DIAGRAM 2
DIAGRAM 3
DIAGRAM 3a
Blue
Blue
Blue
Red
LAMP
LAMP
LAMP
For Two Lamp operation,
Insulate one blue lead to 600V
DIAGRAM 6
DIAGRAM 46
For three lamp operation, cap any
blue lead, insulate to 600V
For Three Lamp Application, Individually
cap brown leads, Insulate to 600V
For one lamp operation, cap any
blue lead, insulate to 600V
DIAGRAM 8
DIAGRAM 30
DIAGRAM 7a
DIAGRAM 49
DIAGRAM
49
DIAGRAM 5050
DIAGRAM
PAGE 1-31
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F28T8 - Four Lamp Applications
347 B432I347HP
120
B432IUNVEL-A
277
4 PAR-IS 120
B432IUNVHE-A
277
120
B432IUNVHP-A
277
4 PAR-PS 120 B432PUNVEL-A
277
120
B432PUNVHE-A
277
120
B432PUNVHEH-E
277
F40T8
• Low Profile
Designs Featured
• Instant & Programmed
Rapid Starting Options
TRIAD® ELECTRONIC BALLASTS
FOR (1), (2), AND (3) F40T8 LAMPS
Fluorescent-Electronic
• 1-3 Lamp Applications
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F40T8 - One Lamp Applications
120
B132IUNVEL-A
277
120
B132IUNVHE-N
277
120
B132IUNVHP-N
277
347 B232I347HP-A
1
IS
347 B232I347HPL
120
B232IUNVHP-N
277
347 B232I347RH-A
120
B232IUNV-C
277
120
B232PUNVEL-B
277
1
PS
120
B232PUNVHE-B
277
F40T8 - Two Lamp Applications
347 B259I347HP
347 B332I347HPL
120
B332IUNVEL-A
2 PAR-IS 277
120
B332IUNVHE-A
277
120
B332IUNVHP-A
277
120
B332PUNVEL-A
277
2 PAR-PS
120
B332PUNVHE-A
277
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.25
> .98
32
0.76
2.38
< 10 0/-18
1
-A
0.13
> .95
0.30
35
> .99
0.86
2.46
< 10 0/-18
1
-N
0.14
0.31 37
2.32
> .99
0.86
< 10 32/0
1
-N
0.13
36 2.39
0.13
45
> .98 1.02
2.27
<10 0/-18
3a
-A
0.11
38
> .98 0.86
2.26
< 10 0/-18
3a
ST
0.36 44
2.34
> .99
1.03
< 10 32/0
3a
-N
0.16
43
2.40
0.13
45
> .98 1.02
2.27
< 20 0/-18
3a
-A
0.37 43
2.30
> .98 0.99
< 10 0/-18
22
-C
0.16
42
2.36
0.28
34
> .99
2.38
0.80
<10 -20/-29 30 -B
0.13
32
> .95
2.52
0.34 41
2.43
> .90
0.99
<10 -20/-29 30 -B
0.15 40
2.48
0.22
76
> .98 0.91
1.20
< 10 0/-18
14
0.20
69
> .99 0.82
1.18
< 10 0/-18
6
0.57
68
> .99
1.31
0.89
< 10 0/-18
6
0.25
66
> .98
1.35
0.64
77
> .99
1.29
0.99
< 10 0/-18
6
0.27
75
> .98
1.32
0.65
78
> .99
1.22
0.95
< 10 0/-18
6
0.29
77
> .95
1.23
0.53
64
> .99
1.34
0.85
<10 -20/-29 30
0.23
62
> .97
1.36
0.64 77
1.33
> .90
1.02
<10 -20/-29 30
0.27 74
1.38
ST
ST
-A
-A
-A
-A
-A
See page 1-33 for Dimensions
and Wiring Diagrams
PAGE 1-32
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
F40T8
FOR F40T8 LAMPS
Overall Dimensions
Draw #
L
ST
-A
-B
-C
9.50”
9.50”
9.50”
14.25”
W
2.40”
1.70”
1.50”
1.18”
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.29
100 > .99 0.81
0.81
< 10 0/-18
7
0.81
97
> .99
0.89
0.86
< 10 0/-18
7a
0.35
94
> .98
0.91
0.93
111 > .99
0.86
0.96
< 10 0/-18
7a
0.39
107 > .98
0.90
0.95
114 > .99
0.81
0.92
< 10 0/-18
7a
0.41
109 > .98
0.84
0.79
95
> .99
0.74
0.70
<10 -20/-29 49
0.34
92
> .98
0.76
0.93 111
0.84
> .90
0.93
<10 -20/-29 49
0.40 109
0.85
ST
-A
-A
-A
-A
-A
Fluorescent-Electronic
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F40T8 - Three Lamp Applications
347 B432I347HPL
120
B432IUNVEL-A
277
3 PAR-IS
120
B432IUNVHE-A
277
120
B432IUNVHP-A
277
120
B432PUNVEL-A
277
3 PAR-PS
120
B432PUNVHE-A
277
Mounting Dimensions
H
M
X
1.55”
1.18”
1.00”
1.00”
8.89” 1.69”
8.89” 1.69”
8.89” 0.88”
13.75” ---
-A, -B
ST
-C
WIRING DIAGRAMS
Line
Black
White
BALLAST
Blue
Blue
Blue
Red
LAMP
LAMP
LAMP
For Two Lamp Operation,
Insulate one blue lead to 600V
DIAGRAM 1
Line
Black
White
Yellow
Yellow
DIAGRAM 2
DIAGRAM 3a
DIAGRAM 6
Blue
BALLAST
Blue
Red
Red
LAMP
LAMP
LAMP
LAMP
For Three Lamp Operation,
Insulate one blue lead to 600V
For three lamp operation, cap any
blue lead, insulate to 600V
DIAGRAM 7
DIAGRAM 7a
For one lamp operation, cap any
blue lead, insulate to 600V
DIAGRAM 14
DIAGRAM 30
DIAGRAM 22
DIAGRAM 49
DIAGRAM
49
PAGE 1-33
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
T8
• Instant Starting Options
SLIMLINE
Slimline Lamps
• 1-2 Lamp Applications
• 8’ T8 SLIMLINE
Fluorescent-Electronic
• High Performance
Models
TRIAD® ELECTRONIC BALLASTS
FOR (1) AND (2)
F48T8, F72T8, F96T8 AND F96T8ES LAMPS
Lamp
Line
Input Power Ballast
Ballast
Min. F/C
Starting Line
Catalog
Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method Volts
Number
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
F48T8 - One Lamp Applications
120 B244 I120HE
0.30
35
> .95 1.04
2.97
0/-18 14 ST
1 IS
< 10
277 B244 I277HE-A
0.14
36
> .90 1.06
2.94
0/-18
14
-A
F48T8 - Two Lamp Applications
120 B244 I120HE
0.47
55
0.90
1.64
0/-18 14 ST
> .95
2 PAR-IS
< 10
277 B244 I277HE-A
0.21
56
0.89 1.59 0/-18 14 -A
F72T8 - One Lamp Applications
120 B244 I120HE
0.42
50
1.03
2.06
0/-18 14 ST
> .95
1 IS
< 10
277 B244 I277HE-A
0.19
52
1.04 2.00 0/-18 14 -A
F72T8 - Two Lamp Applications
120 B244 I120HE
0.70
0.88
1.07
0/-18 14 ST
82
> .95
2 PAR-IS
< 10
277 B244 I277HE-A
0.30
0.87 1.06 0/-18 14 -A
F96T8 - One Lamp Applications
120
0.54
> .99
B259IUNVEL-A
64
0.99
1.55
< 10
32/0
15
-A
277
0.24
> .97
120
0.60
72
> .99
1.50
B259IUNVHP-A
1.08
< 10 32/0
14
-A
1
IS
277
0.26
71
> .98
1.52
120
0.60
71
> .99
1.52
B259IUNVHE-A
1.08
< 10
32/0
15
-A
277
0.26
70
> .97
1.54
120
0.93
111 > .99
0.79
-A
B259IUNVEL-A
.88
< 10
32/0
15
277
0.39
108 > .98
0.81
347 B259I347HP
0.20
68
> .97 1.05
1.54
< 10 32/0
14
ST
F96T8 - Two Lamp Applications
120
0.84
101 > .99
0.77
-A
B259IUNVEL-A
.78
< 10
32/0
15
277
0.36
99
> .98
0.79
120
0.92
108 > .99
0.81
-A
B259IUNVHE-A
.88
< 10 60/16
15
277
0.39
107 > .99
0.82
120
0.95
113 > .99
0.78
2 PAR-IS
B259IUNVHP-A
0.88
< 10 32/0
14
-A
277
0.40
110 > .98
0.80
347 B259I347HP
0.33
113 > .99 0.89
0.79
< 10 32/0
14
ST
F96T8ES (57W) - One Lamp Applications
120
0.56
67
> .99
1.61
1 IS
B259IUNVHE-A
1.08
< 10 60/16 15 -A
277
0.26
66
> .97
1.64
120
0.51
> .99
B259IUNVEL-A
61
0.99
1.62
< 10 60/16 15 -A
277
0.23
> .97
F96T8ES (57W) - Two Lamp Applications
120
0.92
108 > .99
0.81
B259IUNVHE-A
0.88
< 10 60/16 15 -A
277
0.39
107 > .99
0.82
2 PAR-IS
120
0.80
95
> .99
0.82
B259IUNVEL-A
0.78
< 10 60/16 15 -A
277
0.34
93
> .98
0.84
F96T8ES (54W) - One Lamp Applications
120
0.51
61
> .99
1.77
1 IS
B259IUNVHE-A
1.08
< 10 60/16 15 -A
277
0.23
60
> .96
1.80 F96T8ES (54W) - Two Lamp Appl
F96T8ES (54W) - Two Lamp Applications
120
0.80
95
> .99
0.93
2 PAR-IS
B259IUNVHE-A
0.88
< 10 60/16 15 -A
277
0.34
93
> .98
0.95
F96T8ES (49W) - One Lamp Applications
120
0.41
48
> .99
2.06
1 IS
B259IUNVEL-A
0.99
< 10 60/16 15 -A
277
0.19
49
> .96
2.02 F96T8ES (54W) - Two Lamp Appl
F96T8ES (49W) - Two Lamp Applications
120
0.64
77
> .99
1.01
2 PAR-IS
B259IUNVEL-A
0.78
< 10 60/16 15 -A
277
0.28
76
> .98
1.03
IS = Instant Start
PS = Programmed Start
RS = Rapid Start
PAR-IS = Parallel Instant Start
STARTING METHOD LEGEND
PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
SER-IS = Series Instant Start
See page 1-33 for Dimensions
and Wiring Diagrams
PAGE 1-34
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (1) AND (2)
F48T8HO, F60T8HO, F72T8HO AND
F96T8HO LAMPS
IS = Instant Start
PS = Programmed Start
Overall Dimensions
Draw #
L
SL
-S
11.75”
11.75”
RS = Rapid Start
PAR-IS = Parallel Instant Start
W
• 1-2 Lamp Applications
High Output Lamps
• 4-8’ T8 High Output
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.75
> .98
< 10
93 0.98 1.05
-20/-29 4a
0.34
> .95
< 12
-S
0.41
> .96
< 10
49 1.01 2.06
-20/-29 4
0.19
> .92
< 15
-S
0.80
> .98
< 10
96 1.00 1.04
-20/-29 4a
0.36
> .95
< 12
-S
1.57
0.67
-S
187
184
> .98
0.95
> .96
STARTING METHOD LEGEND
PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start
0.51
0.52
< 10 -20/-29
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
4
SER-IS = Series Instant Start
Mounting Dimensions
H
M
X
3.13” 1.78” 11.14” 2.00”
1.70” 1.18” 11.19” 1.05”
WIRING DIAGRAMS
For One Lamp Operation,
Insulate one blue lead to 600V
Yellow leads must be connected
to plunger end of fixture
For One Lamp Applications, individually
cap yellow leads, Insulate fo 600V
DIAGRAM 3
DIAGRAM 4
DIAGRAM 4a
PAGE 1-35
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F48T8HO - One Lamp Applications
120
1 PS
B286PUNVHE-S
277
F48T8HO - Two Lamp Applications
120
2 SER-PS
B286PUNVHE-S
277
F96T8HO - One Lamp Applications
120
1 PS
B286PUNVHE-S
277
F96T8HO - Two Lamp Applications
120
2 SER-PS
B286PUNVHE-S
277
T8HO
• Instant Starting Options
• Multiple Lamp Operation
• Rapid and Programmed Starting Options
• T5 Ballasts meet ANSI requirement for
end-of-lamp life safety shutdown
• Super Low Profile Designs
• 1-2 Lamp Applications
Fluorescent-Electronic
T5
TRIAD® T5 ELECTRONIC
BALLASTS
FOR F8, F13, F14, F21 AND F24 LAMPS
Lamp
Line
Input Power Ballast
Ballast
Min. F/C
Starting Line
Catalog
Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method Volts
Number
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
F14T5 - One Lamp Applications
120
0.12
> .99
< 10
B114PUNV70-D
14
0.70
5.00
277
0.06
> .90
< 15 50/10 43 -D
120
0.14
> .98
B228PUNV-C
17
1.05
6.17
< 10 0/-18
40
-C
1 PS
277
0.07
> .90
120
0.15
> .98
B228PUNV-N
17
1.02
6.17
< 10 0/-18
40
-N
277
0.07
> .90
120
0.14
16
> .98
5.56
< 15
B228PUNV90-C
0.89
277
0.07
17
> .85
5.24
< 20 0/-18 37 -C
120
0.14
16
> .98
6.00
B228PUNV95-D
0.96
< 10 0/-18
40
-D
277
0.07
17
> .85
5.65
F14T5 - Two Lamp Applications
120
0.28
> .98
B228PUNV-C
32
1.00
3.12
< 10 0/-18
37
-C
277
0.12
> .95
120
0.27
> .98
B228PUNV-N
33
1.01
3.06
< 10 0/-18
37
-N
277
0.12
> .95
120
0.24
> .99
B228PUNV85-D
29
0.88
3.03
< 10 0/-18
30
-D
277
0.11
> .97
2 SER-PS
120
0.24
> .99
< 10
B228PUNV90-C
29
0.89 3.07
277
0.11
> .90
< 15 0/-18 37 -C
120
0.26
31
> .99
3.06
B228PUNV95-D
0.95
< 10 0/-18
37
-D
277
0.12
32 > .95
2.97
120
0.31
37
> .99
3.12
B228PUNV115-D
1.15
< 10 0/-18
37
-D
277
0.13
36 > .98
3.19
F21T5 - One Lamp Applications
120
0.13
15
> .99
3.33
< 10 50/10 43 -D
277 B128PUNV50-D
0.07
16 > .86 0.50
3.13
120
0.14
> .99
20
< 10 50/10 43 -D
277 B128PUNV60-D
0.07
> .88 0.60 3.00
120
0.18
21
> .99
3.33
< 10 50/10 43 -D
277 B128PUNV70-D
0.08
22
> .90 0.70
3.18
120
0.20
> .98
24
< 10 0/-18 40 -C
277 B228PUNV-C
0.09
> .95 1.03 4.29
120
0.20
> .98
1
PS
24
< 10 0/-18 40 -N
277 B228PUNV-N
0.10
> .95 1.01 4.21
120
0.19
22
> .99
4.05
< 10
277 B228PUNV90-C
0.09
23 > .90 0.89
3.87
< 15 0/-18 37 -C
120
0.20
> .99
24
< 10 0/-18 40 -D
277 B228PUNV95-D
0.09
> .90 0.96 4.00
F21T5 - Two Lamp Applications
120
0.41
48
2.08
> .98
1.00
< 10 0/-18
37
-C
277 B228PUNV-C
0.17
46
2.17
120
0.39
47
2.13
> .98
1.00
< 10 0/-18
37
-N
277 B228PUNV-N
0.17
46
2.17
120
0.35
41
> .99
2.10
277
B228PUNV85-D
0.86
< 10 0/-18
30
-D
0.15
40
> .98
2.15
2 SER-PS
120
0.35
> .99
42
2.12
< 10 0/-18
37
-C
277 B228PUNV90-C
0.16
> .95 0.89
120
0.40
> .99
B228PUNV95-D
47
0.95
2.02
< 10 0/-18
37
-D
277
0.17
> .95
120
0.44
52
> .99
2.21
B228PUNV115-D
1.15
< 10 0/-18
37
-D
277
0.19
51 > .98
2.25
See page 1-41 for Dimensions and Wiring Diagrams
IS = Instant Start
PS = Programmed Start
RS = Rapid Start
PAR-IS = Parallel Instant Start
STARTING METHOD LEGEND
PAR-PS = Parallel Programmed Start
SER-PS = Series Programmed Start
PAGE 1-36
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
SER-IS = Series Instant Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® T5 ELECTRONIC
BALLASTS
FOR F28 AND F35T5 LAMPS
• Multiple Lamp Operation
• Rapid and Programmed Rapid
Starting Options
• T5 Ballasts meet ANSI requirement for
end-of-lamp life safety shutdown
• Super Low Profile Designs
• 1-2 Lamp Applications
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.17
20
0.08
0.18
22
0.09
25
0.21
25
0.11
27
0.27
32
0.12
0.27
32
0.12
0.25
30
0.11
29
0.25
29
0.11
30
0.25
30
0.11
0.55
0.23
0.54
0.23
0.48
0.21
0.48
0.21
0.51
0.22
0.59
0.25
63
61
65
64
54
53
58
56
61
60
69
68
> .99
< 10
> .90 0.50 2.50
< 12
> .99
2.73
< 10
> .92 0.60
2.40
> .99
2.80
< 10
> .93 0.70
2.59
> .98
1.00
3.12
< 10
> .95
> .98
1.00
3.12
< 10
> .95
> .99
2.93
0.88
< 10
> .98
3.00
> .99
3.10
< 10
> .90 0.90
3.00
< 15
> .99
0.96
3.20
< 10
> .95
1.59
1.00
< 10
1.64
1.54
> .98
1.00
< 10
1.56
> .99
1.57
0.85
< 10
> .98
1.60
1.55
> .98
0.90
< 10
1.61
> .99
1.56
0.95
< 10
> .98
1.58
> .99
1.67
1.15
< 10
> .98
1.69
> .98
50/10 43 -D
50/10 43 -D
0/-18
40
-C
0/-18
40
-N
0/-18
40
-D
0/-18
37
-C
0/-18
40
-D
0/-18
37
-C
0/-18
37
-N
0/-18
30
-D
0/-18
37
-C
0/-18
37
-D
0/-18
37
-D
0.24
29
0.11
> .99
0.96
< 10
0/-18
40
-D
0.48
0.21
> .99
1.67
0.95
< 10
1.70
0/-18
37
-D
< 10
0/-18
40
-N
< 10
0/-18
40
-D
0/-18
37
-N
0/-18
37
-D
< 10
50/10
43
-D
< 10
0/-18
40
-D
< 10
0/-18
40
-C
< 10
0/-18
40
-N
57
56
0.24
29
0.11
0.23
28
0.11
0.49
0.21
0.47
0.20
59
58
56
54
0.25
30
0.12
0.32
38
0.14
0.33
40
0.15
0.33
40
0.15
> .98
> .95 1.00
> .99
> .95 0.96
> .98
> .99
3.31
50/10 43 -D
3.45
3.43
1.69
1.00
< 10
1.72
1.70
0.95
< 10
1.76
> .99
> .95 0.70
> .99
> .97 0.95
> .99
> .97 1.00
> .99
> .95 1.00
2.33
2.50
2.50
2.50
See page 1-41 for Dimensions and Wiring Diagrams
PAGE 1-37
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F28T5 - One Lamp Applications
120
277 B128PUNV50-D
120
277 B128PUNV60-D
120
277 B128PUNV70-D
120
277 B228PUNV-C
120
277 B228PUNV-N
120
B228PUNV85-D
277
120
1 PS
277 B228PUNV90-C
120
B228PUNV95-D
277
F28T5 - Two Lamp Applications
120
277 B228PUNV-C
120
277 B228PUNV-N
120
B228PUNV85-D
277
120
277 B228PUNV90-C
2 SER-PS
120
277 B228PUNV95-D
120
277 B228PUNV115-D
F28T5ES (26W) - One Lamp Applications
120
1 PS
277 B228PUNV95-D
F28T5ES (26W) - Two Lamp Applications
120
2 SER-PS
277 B228PUNV95-D
F28T5ES (25W) - One Lamp Applications
120
1 PS
277 B228PUNV-N
120
277 B228PUNV95-D
F28T5ES (25W) - Two Lamp Applications
120
2 SER-PS
277 B228PUNV-N
120
277 B228PUNV95-D
F35T5 - One Lamp Applications
120
277 B135PUNV70-D
120
277 B228PUNV95-D
120
1 PS
277 B228PUNV-C
120
277 B228PUNV-N
T5
Fluorescent-Electronic
T5HO
• Multiple Lamp Operation
• Programmed Rapid and
Instant Starting Models
• T5HO Ballasts meet ANSI
requirements for end-of-lamp
life safety shutdown
• Super Low Profile Designs
• 1-4 Lamp Applications
TRIAD® T5HO ELECTRONIC
BALLASTS
FOR F24, F39 AND
F54 T5HO LAMPS
Lamp
Line
Input Power Ballast
Ballast
Min. F/C
Starting Line
Catalog
Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method Volts
Number
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
F24T5HO - One Lamp Applications
120
0.23
> .98
1 PS
B224PUNV-C
28 1.06
3.79
< 10 0/-18
40
-C
277
0.10
> .95
F24T5HO - Two Lamp Applications
120
0.45
53
1.89
B224PUNV-C
> .98 1.00
< 10 0/-18
37
-C
277
0.19
52
1.92
2 SER-PS
120
0.51
> .98
B239PUNV-D
59 1.15
1.95
< 10 0/-18
37
-D
277
0.22
> .95
F39T5HO - One Lamp Applications
120
0.34
41
2.32
B224PUNV-C
> .98 0.95
< 10 0/-18
40
-C
277
0.15
40
2.38
1 PS
120
0.39
> .98
B239PUNV-D
47 1.10
2.34
< 10 0/-18
40
-D
277
0.18
> .95
F39T5HO - Two Lamp Applications
120
0.75
89
1.12
2 SER-PS
B239PUNV-D
> .98 1.00
< 10 0/-18
37
-D
277
0.32
88
1.14
F54T5HO - One Lamp Applications
347 B254P347-D
0.19
64
> .95 1.02
1.59
< 10 -20/-29 37
-D
347
0.19
> .98
< 10
B254PHRVHB-E
66
1.02 1.55
-20/-29 42 -E
480
0.15
> .90
< 15
120
0.49
> .99
B254PUNV-D
59
1.00
1.69
< 10 -20/-29 40
-D
1
PS
277
0.22
> .96
120
0.49
> .99
B254PUNVHB-D
59
1.00
1.69
< 10 -20/-29 40
-D
277
0.22
> .96
120
0.50
60
> .99 1.00
1.67
< 10 -20/-29 A -A
277 B254PUNVPL-A
0.23
59
> .94 1.02
1.71
120
0.50
60
> .99 1.00
1.67
B254PUNVPLHBA
< 10 -20/-29 A -A
277
0.23
59
> .94 1.02
1.71
120
0.54
> .95
< 15
B454PUNV-E
65
1.05 1.62 -20/-29 44 -E
277
0.26
> .90
< 20
120
0.54
> .95
< 15
B454PUNVHB-E
65
1.05 1.62 -20/-29 44 -E
277
0.26
> .90
< 20
F54T5HO - Two Lamp Applications
347
0.35
120 > .98
0.83
B254PHRVHB-E
1.00
< 10 -20/-29 41
-E
480
0.26
119 > .95
0.84
120
0.96
116 > .99
0.86
B254PUNV-D
1.00
< 10 -20/-29 37
-D
277
0.41
113 > .98
0.88
120
0.96
116 > .99
0.86
B254PUNVHB-D
1.00
< 10 -20/-29 37
-D
2 SER-PS 277
0.41
113 > .98
0.88
347 B254P347-D
0.35
120 > .98 1.00
0.83
< 10 -20/-29 37
-D
120
1.01 122
0.82
< 10
B454PUNV-E
> .95 1.00
-20/-29 44 -E
277
0.44
121
0.83
< 15
120
1.01 122
0.82
< 10
B454PUNVHB-E
> .95 1.00
-20/-29 44 -E
277
0.44
121
0.83
< 15
120
0.94
113 > .99 0.96
0.85
< 10 -20/-29 A -A
277 B254PUNVPL-A
0.40
110 > .98 0.99
0.90
2 PAR-PS
120
0.94
113 > .99 0.96
0.85
B254PUNVPLHBA
< 10 -20/-29 A -A
277
0.40
110 > .98 0.99
0.90
F54T5HO - Three Lamp Applications
120
1.52
184 > .98
0.57
B454PUNV-E
1.05
< 10 -20/-29 44
-E
277
0.66
182 > .95
0.58
3 SER-PS
120
1.52
184 > .98
0.57
B454PUNVHB-E
1.05
< 10 -20/-29 44
-E
277
0.66
182 > .95
0.58
120
1.34
159 > .99
0.90 0.57
< 10 -20/-29 B -E
277 B454PUNVPL-E
0.58
157 > .97
3 PAR-PS
120
1.34
159 > .99
0.90 0.57
< 10 -20/-29 B -E
277 B454PUNVPLHBE
0.58
157 > .97
See page 1-41 for Dimensions and Wiring Diagrams
PAGE 1-38
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® T5HO ELECTRONIC
BALLASTS
FOR F24, F39 AND
F54 T5HO LAMPS
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
• Multiple Lamp Operation
• Programmed Rapid and Instant Starting
Models
• T5HO Ballasts meet ANSI requirements for
end-of-lamp life safety shutdown
• Super Low Profile Designs
• 1-4 Lamp Applications
T5HO
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
> .98
0.43
1.00
< 10 -20/-29 44
-E
> .99
0.44
> .98
0.43
1.00
< 10 -20/-29 44
-E
> .99
0.44
> .99
0.90 0.43
< 10 -20/-29 B -E
> .98
> .99
1.00
> .96
> .99
1.00
> .93
> .99
1.00
> .93
1.82
< 10
1.81
< 10
1.83
1.81
< 10
1.83
> .99
0.93
1.00
< 10
> .98
0.97
> .99
0.92
0.96
< 10
> .97
0.95
> .99
0.92
0.96
< 10
> .97
0.95
> .99
0.90
> .97
> .99
0.90
> .97
0.60
< 10
0.61
0.60
< 10
0.61
> .99
0.90
> .97
> .99
0.90
> .97
0.46
< 10
0.47
0.46
< 10
0.47
> .99
> .92
> .99
> .92
1.00
0.99
1.00
0.99
1.79
< 10
1.80
1.79
< 10
1.80
> .99
0.96
> .97
> .99
0.96
> .97
0.90
< 10
0.93
0.90
< 10
0.93
> .99
0.90
> .97
> .99
0.90
> .97
0.58
< 10
0.60
0.58
< 10
0.60
> .99
0.90
> .98
> .99
0.90
> .98
0.45
< 10
0.46
0.45
< 10
0.46
> .99
1.00
> .96
> .99
1.00
> .96
> .99
1.00
> .92
> .99
1.00
> .92
1.85
< 10
1.89
1.85
< 10
1.89
1.85
< 10
1.89
1.85
< 10
1.89
Page 1-39
60/16
40
-D
60/16 A -A
60/16 A -A
60/16
37
-D
60/16 A -A
60/16 A -A
60/16 B -E
60/16 B -E
60/16 B -E
60/16 B -E
60/16 A -A
60/16 A -A
60/16 A -A
60/16 A -A
60/16 B -E
60/16 B -E
60/16 B -E
60/16 B -E
60/16 40 -D
60/16 40 -D
60/16 A -A
60/16 A -A
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
F54T5HO - Four Lamp Applications
120
1.96
235
B454PUNV-E
277
0.84
229
4 SER-PS
120
1.96
235
B454PUNVHB-E
277
0.84
229
120
1.77
210
4 PAR-PS
B454PUNVPLHBE
277
0.76
207
F54T5HOES (51W) - One Lamp Applications
120
0.46
B254PUNV-D
55
277
0.20
120
0.46
1 PS
B254PUNVPL-A
55
277
0.21
120
0.46
B254PUNVPLHBA
55
277
0.21
F54T5HOES (51W) - Two Lamp Applications
120
0.89
107
2 SER-PS
B254PUNV-D
277
0.37
103
120
0.90
104
277 B254PUNVPL-A
0.39
101
2 PAR-PS
120
0.90
104
277 B254PUNVPLHBA
0.39
101
F54T5HOES (51W) - Three Lamp Applications
120
1.27
151
277 B454PUNVPL-E
0.55
148
3 PAR-PS
120
1.27
151
277 B454PUNVPLHBE
0.55
148
F54T5HOES (51W) - Four Lamp Applications
120
1.65
196
277 B454PUNVPL-E
0.71
192
4 PAR-PS
120
1.65
196
277 B454PUNVPLHBE
0.71
192
F54T5HOES (50W) - One Lamp Applications
120
0.47
56
277 B254PUNVPL-A
0.21
55
1 PS
120
0.47
56
277 B254PUNVPLHBA
0.21
55
F54T5HOES (50W) - Two Lamp Applications
120
0.92
106
277 B254PUNVPL-A
0.40
103
2 PAR-PS
120
0.92
106
277 B254PUNVPLHBA
0.40
103
F54T5HOES (50W) - Three Lamp Applications
120
1.30
154
277 B454PUNVPL-E
0.56
151
3 PAR-PS
120
1.30
154
277 B454PUNVPLHBE
0.56
151
F54T5HOES (50W) - Four Lamp Applications
120
1.67
198
277 B454PUNVPL-E
0.72
194
4 PAR-PS
120
1.67
198
277 B454PUNVPLHBE
0.72
194
F54T5HOES (49W) - One Lamp Applications
120
0.44
54
B254PUNV-D
277
0.20
53
120
0.44
54
B254PUNVHB-D
1
PS
277
0.20
53
120
0.45
54
B254PUNVPL-A
277
0.21
53
120
0.45
54
B254PUNVPLHBA
277
0.21
53
• Multiple Lamp Operation
• Programmed Rapid and
Instant Starting Models
• T5HO Ballasts meet ANSI
requirements for end-of-lamp
life safety shutdown
• Super Low Profile Designs
• 1-4 Lamp Applications
T5HO
Fluorescent-Electronic
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
TRIAD® T5HO ELECTRONIC
BALLASTS
FOR F24, F39 AND
F54 T5HO LAMPS
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
F54T5HOES (49W) - Two Lamp Applications
120
0.87
277 B254PUNV-D
0.37
2 SER-PS
120
0.87
277 B254PUNVHB-D
0.37
120
0.86
277 B254PUNVPL-A
0.37
2 PAR-PS
120
0.86
277 B254PUNVPLHBA
0.37
F54T5HOES (49W) - Three Lamp Applications
120
1.19
277 B454PUNVPL-E
0.52
3 PAR-PS
120
1.19
277 B454PUNVPLHBE
0.52
F54T5HOES (49W) - Four Lamp Applications
120
1.61
277 B454PUNVPL-E
0.69
4 PAR-PS
120
1.61
277 B454PUNVPLHBE
0.69
F54T5HOES (47W) - One Lamp Applications
120
0.42
277 B254PUNV-D
0.20
120
0.45
1 PS
277 B254PUNVPL-A
0.21
120
0.45
277 B254PUNVPLHBA
0.21
F54T5HOES (47W) - Two Lamp Applications
120
0.85
277 B254PUNV-D
0.36
120
0.86
277 B254PUNVPL-A
0.37
2 PAR-PS
120
0.86
277 B254PUNVPLHBA
0.37
F54T5HOES (47W) - Three Lamp Applications
120
1.21
277 B454PUNVPL-E
0.53
3 PAR-PS
120
1.21
277 B454PUNVPLHBE
0.53
F54T5HOES (47W) - Four Lamp Applications
120
1.59
277 B454PUNVPL-E
0.68
4 PAR-PS
120
1.59
277 B454PUNVPLHBE
0.68
105
102
105
102
103
101
103
101
> .99
1.00
> .98
> .99
1.00
> .98
> .99
0.97
> .97
> .99
0.97
> .97
0.95
< 10
0.98
0.95
< 10
0.98
0.94
< 10
0.96
0.94
< 10
0.96
142
140
142
140
> .99
0.90
> .96
> .99
0.90
> .96
0.63
< 10
0.64
0.63
< 10
0.64
192
188
192
188
> .99
0.90
> .98
> .99
0.90
> .98
0.47
< 10
0.48
0.47
< 10
0.48
54
53
54
53
54
53
> .99
1.00
> .95
> .99
1.00
> .92
> .99
1.00
> .92
1.85
< 10
1.89
1.86
< 10
1.87
1.86
< 10
1.87
102
99
100
98
100
98
> .99
0.98
1.00
< 10
> .98
1.01
> .99
0.96
< 10
0.96
> .97
> .99
0.96
< 10
0.96
> .97
144
142
144
142
> .99
0.90 0.63
< 10
> .96
> .99
0.90 0.63
< 10
> .96
189
185
189
185
> .99
0.90
> .97
> .99
0.90
> .97
0.48
< 10
0.49
0.48
< 10
0.49
60/16 37 -D
60/16 37 -D
60/16 A -A
60/16 A -A
60/16 B -E
60/16 B -E
60/16 B -E
60/16 B -E
60/16 40 -D
60/16 A -A
60/16 A -A
60/16 37 -D
60/16 A -A
60/16 A -A
60/16 B -E
60/16 B -E
60/16 B -E
60/16 B -E
See page 1-41 for Dimensions and Wiring Diagrams
For one lamp operation,
cap blue leads individually,
insulate to 600V.
For three lamp operation, cap
Blue/White leads individually,
insulate to 600V.
DIAGRAM A
DIAGRAM B
DIAGRAM 50
Page 1-40
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
T5
TRIAD® T5 & T5HO ELECTRONIC
BALLASTS
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
&
T5HO
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
Overall Dimensions
Draw #
L
-C
-D
-E
14.25”
16.88”
16.88”
W
> .99
1.00
> .92
> .99
1.00
> .92
1.95
< 10
1.96
1.95
< 10
1.96
> .99
0.93
> .97
> .99
0.93
> .97
0.96
< 10
0.98
0.96
< 10
0.98
> .99
0.92
> .96
> .99
0.92
> .96
0.70
< 10
0.71
0.70
< 10
0.71
> .99
0.92
> .97
> .99
0.92
> .97
0.53
< 10
0.54
0.53
< 10
0.54
60/16 A -A
60/16 A -A
60/16 A -A
60/16 A -A
60/16 B -E
60/16 B -E
60/16 B -E
60/16 B -E
Mounting Dimensions
H
M
X
1.18” 1.00” 13.75”
1.18” 1.00” 16.20”
1.74” 1.18” 16.28”
—
—
—
-C, -D
-E
WIRING DIAGRAMS
DIAGRAM 4b
DIAGRAM 37
DIAGRAM 40
For one lamp operation, individually cap yellow
and yellow/black leads, insulate to 600V.
DIAGRAM 42
DIAGRAM 30
DIAGRAM 41
DIAGRAM 43
PAGE 1-41
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
F54T5HOES (44W) - One Lamp Applications
120
0.43
51
277 B254PUNVPL-A
0.20
1 PS
120
0.43
51
277 B254PUNVPLHBA
0.20
F54T5HOES (44W) - Two Lamp Applications
120
0.81
97
277 B254PUNVPL-A
0.35
95
2 PAR-PS
120
0.81
97
277 B254PUNVPLHBA
0.35
95
F54T5HOES (44W) - Three Lamp Applications
120
1.10
131
277 B454PUNVPL-E
0.49
130
3 PAR-PS
120
1.10
131
B454PUNVPLHBE
277
0.49
130
F54T5HOES (44W) - Four Lamp Applications
120
1.46
174
277 B454PUNVPL-E
0.63
171
4 PAR-PS
120
1.46
174
277 B454PUNVPLHBE
0.63
171
Fluorescent-Electronic
F30T12,
F30T12ES,
F32T12
• Rapid Starting Options
• Standard & High
Performance Models
T12 Straight Lamps
• 1-3 Lamp Applications
TRIAD® ELECTRONIC BALLASTS
FOR (1), (2) AND (3)
F30T12, F30T12ES, & (2)F32T12 LAMPS
Lamp
Line
Input Power Ballast
Ballast
Min. F/C
Starting Line
Catalog
Current Power Factor Factor Efficacy THD Start
Qty. Method Volts
Number
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
F25T12 - Two Lamp Applications
120
0.40 47
1.89
2 PAR-IS
B232IUNV-C
> .98 0.89
< 10 0/-18
277
0.17 46
1.93
F25T12 - Three Lamp Applications
120
0.58 69
> .99 0.90
1.30
3 PAR-IS
B332IUNVHP-A
< 10 0/-18
277
0.26
68
> .95 0.91
1.34
F25T12 - Four Lamp Applications
120
0.77 91
> .99
0.99
4 PAR-IS
B432IUNVHP-A
0.90
< 10 0/-18
277
0.34
88
> .95
1.02
F32T12 - One Lamp Applications
1
RS
277
B234SR277M-A*
0.15
33
> .80 0.94
2.85
< 30 50/10
F32T12 - Two Lamp Applications
120 B234SR120M-A∆
0.46
54
> .98 0.90
1.67
< 10 50/10
2 SER-RS
277
B234SR277M-A*
0.21
55
> .90 0.87
1.58
< 30 50/10
Wiring
Diag.
Dim.
21
-C
6
-A
7a
-A
4
-A
30
4
-A
-A
∆
Residential use only.
*Not for sale for use in the US.
Overall Dimensions
Draw #
L
ST
-A
9.50”
9.50”
W
2.40”
1.70”
Mounting Dimensions
H
M
X
1.55” 8.89” 1.69”
1.18” 8.89” 1.69”
ST
WIRING DIAGRAMS
-A
DIAGRAM 47
DIAGRAM 44
Line
Black
White
DIAGRAM 48
BALLAST
Blue
Blue
Blue
Red
LAMP
LAMP
LAMP
For One lamp Operation, Individually
Cap blue leads, Insulate to 600V
For Two Lamp Operation,
Insulate one blue lead to 600V
For three lamp operation, cap any
blue lead, insulate to 600V
DIAGRAM 4
DIAGRAM 6
DIAGRAM 7a
DIAGRAM 30
DIAGRAM 21
PAGE 1-42
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
FOR (1) , (2) AND (3)
F40T12 AND F34T12ES LAMPS
• Standard & High
Performance Models
• Rapid Starting Options
F40T12
&
T12 Straight Lamps
F34T12ES
• 1-3 Lamp Applications
T12 U-Shaped Lamps
Wiring
Diag.
Dim.
4
4
-A
-A
30
4
4
-A
-A
-A
4
4
-A
-A
30
4
4
-A
-A
-A
∆
Residential use only.
* Not for sale for use in the US.
Overall Dimensions
Draw #
L
-A
9.50”
W
1.70”
Mounting Dimensions
H
M
X
WIRING DIAGRAMS
1.18” 8.89” 1.69”
-A
For One Lamp Applications, individually
cap blue leads, Insulate fo 600V
DIAGRAM 4
PAGE 1-43
DIAGRAM 30
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp
Line
Input Power Ballast
Ballast
Min. F/C
Starting Line
Catalog
Current Power Factor Factor Efficacy THD Start
Qty. Method Volts
Number
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
F40T12 - One Lamp Applications
220 B240R220-A*
0.20
44
> .99 1.04
2.38
< 10 50/10
1 RS
277 B234SR277M-A*
0.17
42
> .88 0.94
2.24
< 30 50/10
F40T12 - Two Lamp Applications
120 B234SR120M-A∆
0.58
69
> .98 0.90
1.30
< 10 50/10
2 SER-RS
277 B234SR277M-A*
0.26
70
> .90 0.87
1.24
< 30 50/10
2 PAR-RS 220 B240R200-A*
0.32
70
> .99 0.90
1.29
< 10 50/10
F40T12ES (34W) - One Lamp Applications
220 B240R200-A*
0.17
36
> .99 1.04
2.86
< 10 60/16
1 RS
277 B234SR277M-A*
0.15
35
> .80 0.94
2.69
< 30 60/16
F40T12ES (34W) - Two Lamp Applications
120 B234SR120M-A∆
0.48
58
> .98 0.86
1.48
< 10 60/16
2 SER-RS
277 B234SR277M-A*
0.23
60
> .90 0.87
1.45
< 30 50/10
2 PAR-RS 220 B240R200-A*
0.27
59
> .99 0.90
1.52
< 10 60/16
T12
SLIMLINE
Fluorescent-Electronic
TRIAD® ELECTRONIC BALLASTS
• Standard & High
Performance Models
Slimline Lamps
• Instant Starting Options
FOR F48T12, F48T12ES, F60T12, F64T12 &
F72T12 LAMPS
• 1-2 Lamp Applications
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F48T12 - One Lamp Applications
1 IS 120
B260IUNVHP
277
F48T12 - Two Lamp Applications
2 PAR-IS 120
B260I120M-A*
120
B260IUNVHP
277
F48T12ES - One Lamp Applications
1 IS 120
B260IUNVHP
277
F48T12ES - Two Lamp Applications
2 PAR-IS 120
B260IUNVHP
277
F60T12 - One Lamp Applications
1 IS 120
B260IUNVHP
277
F60T12 - Two Lamp Applications
2 PAR-IS 120
B260IUNVHP
277
F64T12 - One Lamp Applications
1 IS 120
B260IUNVHP
277
F64T12 - Two Lamp Applications
2 PAR-IS 120
B260IUNVHP
277
F72T12 - One Lamp Applications
1 IS 120
B260IUNVHP
277
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.39
47
> .95 1.10
0.18
2.34
< 10
0/-18
14
SL
50/10
14
-A
0/-18
14
SL
0.62
0.61
0.27
68
75
74
> .90 0.90
1.32
< 30
> .98
1.27
0.95
< 10
> .95
1.28
0.32
0.15
38
39
> .98
2.89
1.10
< 10
> .95
2.82
60/16
14
SL
0.57 67
1.39
> .95 0.93
< 10
0.25 66
1.41
60/16
14
SL
0.49
58
0.22
< 10
0/-18
14
SL
0.77 92
1.00
> .98 0.92
< 10
0.33 91
1.01
0/-18
14
SL
0.51
0.35
> .98
1.80
1.10
< 10
> .95
1.15
0/-18
14
SL
0.81 97
0.95
> .98 0.92
< 10
0.35 96
0.96
0/-18
14
SL
0.55 68
1.56
> .95 1.06
< 10
0.25 67
1.58
0/-18
14
SL
61
96
> .98
1.10
> .95
1.90
* Residential use only.
Overall Dimensions
Draw #
L
SL
-A
11.75”
9.50”
W
3.13”
1.70”
Mounting Dimensions
H
M
X
WIRING DIAGRAMS
1.78” 11.14” 2.00”
1.18” 8.89” 1.69”
For One Lamp Operation, Insulate one blue lead to 600V
SL
DIAGRAM 14
-A
PAGE 1-44
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
• Standard & High
Performance Models
F72T12(cont.), F84T12, F96T12 & F96T12ES
LAMPS
• Instant Starting Options
SLIMLINE
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.90
105 > .95 0.90
0.86
< 30
0.90 109
0.83
> .99 0.91
< 10
0.39 107
0.85
50/10
14
-A
0/-18
14
SL
0.63 76
1.45
> .98 1.10
< 10
0.28 75
1.47
0/-18
14
SL
1.03 123
0.72
> .98 0.88
< 10
0.44 120
0.73
0/-18
14
SL
0.70 85
1.24
> .98 1.05
< 10
0.31 84
1.25
0/-18
14
SL
1.16 139
0.63
> .99 0.88
< 10
0.50 137
0.64
0/-18
14
SL
0.61
66
> .90 1.09
1.65
< 30
0.59 72
1.43
> .98 1.03
< 10
0.26 70
1.47
60/16
14
-A
60/16
14
SL
0.90
105 > .95 0.88
0.84
< 30
0.96 112
0.79
> .99 0.88
< 10
0.40 110
0.80
60/16
14
-A
60/16
14
SL
* Residential use only.
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
PAR-IS = Parallel Instant Start
Overall Dimensions
Draw #
L
SL
-A
11.75”
9.50”
SL
W
3.13”
1.70”
STARTING METHOD LEGEND
PAR-PRS = Parallel Programmed Rapid Start
SER-PRS = Series Programmed Rapid Start
Mounting Dimensions
H
M
X
1.78” 11.14” 2.00”
1.18” 8.89” 1.69”
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
SER-IS = Series Instant Start
WIRING DIAGRAMS
For One Lamp Operation, Insulate one blue lead to 600V
-A
DIAGRAM 14
PAGE 1-45
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F72T12 - Two Lamp Applications
2 PAR-IS 120 B260I120M-A*
120
B260IUNVHP
277
F84T12 - One Lamp Applications
1 IS
120
B260IUNVHP
277
F84T12 - Two Lamp Applications
2 PAR-IS 120
B260IUNVHP
277
F96T12 - One Lamp Applications
1 IS
120
B260IUNVHP
277
F96T12 - Two Lamp Applications
2 PAR-IS 120
B260IUNVHP
277
F96T12ES - One Lamp Applications
1
IS
120 B260I120M-A*
120
B260IUNVHP
277
F96T12ES - Two Lamp Applications
2 PAR-IS 120 B260I120M-A*
120
B260IUNVHP
277
• 1-2 Lamp Applications
T12
Slimline Lamps
T12HO
• High Performance
Models
TRIAD® ELECTRONIC BALLASTS
• Rapid Starting Options
• 2 Lamp Applications
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
FOR T12 HIGH
OUTPUT LAMPS
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
Fluorescent-Electronic
F48T12HO - One Lamp Applications
120
0.46
> .98
< 10
1 PS
B295PUNVHE-S
55
0.93
1.69
-20/-29
277
0.22
> .90
< 12
F48T12HO - Two Lamp Applications
120
0.88
105
> .98
0.86
2 SER-PS
B295PUNVHE-S
0.90
< 10 -20/-29
277
0.39
104
> .95
0.87
F60T12HO - One Lamp Applications
120
0.56
> .98
1 PS
B295PUNVHE-S
67
0.92
1.37
< 10 -20/-29
277
0.26 > .92
F60T12HO - Two Lamp Applications
120
1.08
127
> .98
0.70
2 SER-PS
B295PUNVHE-S
0.89
< 10 -20/-29
277
0.47
126
> .95
0.71
F72T12/BL/HO - Two Lamp Applications
2 SER-RS 120 493B2
1.60
180
> .90 1.00
0.56
< 25 50/10
F72T12HO - One Lamp Applications
120
0.70
> .98
1 PS
B295PUNVHE-S
83
0.92
1.11
< 10 -20/-29
277
0.31 > .95
F72T12HO - Two Lamp Applications
120
1.34 157
0.56
2 SER-PS
B295PUNVHE-S
> .98 0.88
< 10 -20/-29
277
0.57 155
0.57
F73T12/BL/HO - Two Lamp Applications
2 SER-RS 120 493B2
1.60
180
> .90 1.00
0.56
< 25 50/10
F96T12HO - One Lamp Applications
120
0.88
104
> .98
0.88
1 PS
B295PUNVHE-S
0.92
< 10 -20/-29
277
0.38
103
> .95
0.89
F96T12HO - Two Lamp Applications
120
1.72 204
0.43
2 SER-PS
B295PUNVHE-S
> .98 0.88
< 10 -20/-29
277
0.72 197
0.45
F96T12HOES (95W) - One Lamp Applications
120
0.73
> .98
1 PS
B295PUNVHE-S
87
0.92
1.06
< 10 60/16
277
0.32 > .95
F96T12HOES (95W) - Two Lamp Applications
120
1.45 170
0.52
2 SER-PS
B295PUNVHE-S
> .98 0.88
< 10 -20/-29
277
0.61 167
0.53
Overall Dimensions
Draw #
L
ST
-S
9.50”
11.75”
W
Mounting Dimensions
H
M
X
80
-S
80
-S
80
-S
80
-S
4
ST
80
-S
80
-S
4
ST
80
-S
80
-S
80
-S
80
-S
WIRING DIAGRAMS
2.40” 1.55” 8.89” 1.69”
1.70” 1.18” 11.19” 1.05”
DIAGRAM 40
ST
SL
DIAGRAM 4
DIAGRAM 80
PAGE 1-46
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
TRIAD® ELECTRONIC BALLASTS
• Programmed Rapid
Starting Options
FOR F6T2, F8T2, F11T2 AND F13T2 LAMPS
• 1-2 Lamp Applications
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F6T2 - One And Two Lamp Applications
120
2 SER-PS
ES1786X
277
120
1 PS
ES1786X
277
F8T2 - One And Two Lamp Applications
120
2 SER-PS
ES1786X
277
120
1 PS
ES1786X
277
F11T2 - One And Two Lamp Applications
120
2 SER-PS
ES1786X
277
120
1 PS
ES1786X
277
F13T2 - One And Two Lamp Applications
120
2 SER-PS
ES1786X
277
120
1 PS
ES1786X
277
T2
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF)
Factor (BEF) %
Temp
Diag.
Dim.
0.12 14
7.14
> .97 1.00
< 10
0.07 15
6.67
0.07 8
12.50
> .97 1.00
< 10
0.05
9
11.11
0.17 20
5.00
> .97 1.00
< 10
0.08 21
4.76
0.10
11
> .97 1.00
9.09
< 10
0.06
37
ESX
0/-18
40
ESX
0/-18
37
ESX
0/-18
40
ESX
26
> .97
1.00
3.85
< 10
0/-18
37
ESX
15
> .97
1.00
6.67
< 10
0/-18
40
ESX
0/-18
37
ESX
0/-18
40
ESX
0.27 31
3.23
> .97 1.00
< 10
0.13 32
3.13
0.15 16
6.25
> .97 1.00
< 10
0.08 17
5.88
STARTING METHOD LEGEND
IS = Instant Start
PRS = Programmed Rapid Start
Overall Dimensions
Draw #
L
ESX
14.13”
RS = Rapid Start
PAR-IS = Parallel Instant Start
W
1.24”
PAR-PRS = Parallel Programmed Rapid Start
SER-PRS = Series Programmed Rapid Start
Mounting Dimensions
H
M
X
0.73”
13.78”
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
SER-IS = Series Instant Start
WIRING DIAGRAMS
—
DIAGRAM 37
ESX
DIAGRAM 40
PAGE 1-47
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent-Electronic
0.20
0.09
0.12
0.07
0/-18
Energy Management System
DCL® with DEMANDflex®
DEMANDflex® ballasts are high efficiency program start
ballasts with the flexibility to be tuned at the circuit level
to fixed power levels during installation. They are fully
compatible with occupancy sensors and exceed the CEE
requirements for high efficiency program start T8
ballasts. DEMANDflex® ballasts having tuning capabilities with ranges from 100% to 50% power levels, making
them applicable for a wide range of lighting installations.
Installations can start with DEMANDflex® ballasts and
after installation, the ballasts can be tuned to maximize
energy savings with fixed light levels. No dimming
control wires are associated with DEMANDflex® ballasts
which makes them easy to install in all existing fluorescent lighting applications. DEMANDflex® ballasts can also
be integrated with DCL® controls to be part of the most
cost-effective lighting system available.
DCL® controls allow for local control with energy management systems and external control via the internet for
networked managed systems. DCL® controls allow for
integration with utility demand response programs that
provide for improved pricing contracts to end-users in
exchange for the utility to have the ability to lower
lighting power levels during periods of high demand.
DCL/DEMANDflex
Universal Lighting Technologies is a member of the Panasonic Group
Product Overview
DEMANDflex® Ballasts
n
Power level tuning potential to 50%
–Set the circuit power level at installation
–Typical 10% to 15% power reduction
n
Install the same as standard PRS ballasts
–No control wires necessary
–Standard mounting footprint
–Same wiring as program rapid start ballasts
n
High efficiency program start operation
–Exceeds CEE T8 requirements
–Compatible with occupancy sensors
n
NEMA premium
–Exceeds CEE T8 requirements
–Compatible with occupancy sensors
DCL® Controlled Systems
n
–Avoid high peak charges
–Reduce demand costs
n
Programmable fade rates
–Gradual transitions
–No disruptions
n
n
DCL/DEMANDflex
Reduces lighting power by up to 50%
Use existing power connections to communicate to the ballasts
–No control wires
Implement with various controls and systems
–BAS Systems
–Photo Cells
–Occupancy Sensors
–Contact Closure
For more information contact Universal or visit www.unvlt.com.
PAGE 2-2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
DEMANDflex®
FOR (1), (2), (3) & (4) LAMPS
DEMANDflex
Universal DCL® Dimming
Programmed Rapid Start
1, 2, 3, & 4 Lamp Applications
Visit www.unvlt.com for a comprehensive
description of the DCL® system and
DEMANDflex® ballasts
•
•
•
•
T8
Certification Line Input Power Ballast Ballast
Lamp
Min. F/C
Starting Line
Catalog Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method Volts
Number
c (Amps) (Watts) (PF)
(BF) Factor (BEF) %
Temp Diag. Dim.
F32T8 - One Lamp Applications
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.24
0.11
0.11
0.05
0.32
0.15
0.14
0.07
0.20
0.09
0.09
0.05
29
14
29
14
38
18
39
19
24
11
24
12
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
0.88
0.28
0.88
0.28
1.15
0.50
1.15
0.50
0.68
0.18
0.68
0.18
3.01
2.05
3.03
1.96
3.03
2.78
2.95
2.63
2.85
1.64
2.85
1.57
< 10
< 15
< 10
< 15
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B232PUNVDR-A @ 100%
120
B232PUNVDR-A @ 50%
B232PUNVDR-A @ 100%
277
B232PUNVDR-A @ 50%
B232PUNVDRH-A @ 100%
120
2 PRS B232PUNVDRH-A @ 50%
B232PUNVDRH-A @ 100%
277
B232PUNVDRH-A @ 50%
B232PUNVDRL-A @ 100%
120
B232PUNVDRL-A @ 50%
B232PUNVDRL-A @ 100%
277
B232PUNVDRL-A @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.47
0.22
0.20
0.10
0.62
0.30
0.26
0.13
0.40
0.19
0.17
0.09
57
28
56
28
75
37
73
36
47
24
47
24
> .95
> .95
> .95
> .95
> .95
> .90
> .95
> .90
> .95
> .95
> .95
> .95
0.87
0.34
0.87
0.35
1.15
0.50
1.15
0.50
0.71
0.19
0.71
0.19
1.53
1.20
1.56
1.22
1.53
1.35
1.58
1.39
1.51
0.81
1.51
0.81
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B332PUNVDR-A @ 100%
120
B332PUNVDR-A @ 50%
B332PUNVDR-A @ 100%
277
B332PUNVDR-A @ 50%
B332PUNVDRL-A @ 100%
120
3 PRS B332PUNVDRL-A @ 50%
B332PUNVDRL-A @ 100%
277
B332PUNVDRL-A @ 50%
B332PUNVDRH-E @ 100%
120
B332PUNVDRH-E @ 50%
B332PUNVDRH-E @ 100%
277
B332PUNVDRH-E @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.70
0.34
0.30
0.16
0.59
0.29
0.25
0.13
0.95
0.48
0.41
0.21
85
42
83
41
72
36
72
36
115
57
111
55
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
0.87
0.35
0.87
0.35
0.71
0.22
0.71
0.22
1.15
0.50
1.15
0.50
1.02
0.83
1.05
0.85
0.99
0.61
0.99
0.61
1.00
0.88
1.04
0.91
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12c
12c
12c
12c
12c
12c
12c
12c
12d
12d
12d
12d
-A
-A
-A
-A
-A
-A
-A
-A
-E
-E
-E
-E
B432PUNVDR-E @ 100%
120
B432PUNVDR-E @ 50%
B432PUNVDR-E @ 100%
277
4 PRS B432PUNVDR-E @ 50%
B432PUNVDRL-E @ 100%
120
B432PUNVDRL-E @ 50%
B432PUNVDRL-E @ 100%
277
B432PUNVDRL-E @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.96
0.48
0.41
0.20
0.78
0.37
0.34
0.17
116
58
112
56
93
47
93
47
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .95
0.88
0.35
0.88
0.35
0.71
0.21
0.71
0.21
0.75
0.60
0.79
0.63
0.76
0.45
0.76
0.45
< 10
< 10
< 10
< 15
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12e
12e
12e
12e
12e
12e
12e
12e
-E
-E
-E
-E
-E
-E
-E
-E
F32T8 - Two Lamp Applications
F32T8 - Three Lamp Applications
F32T8 - Four Lamp Applications
See page 2-7 for Dimensions and Wiring Diagrams
PAGE 2-3
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
DEMANDflex
B232PUNVDR-A @ 100%
120
B232PUNVDR-A @ 50%
B232PUNVDR-A @ 100%
277
B232PUNVDR-A @ 50%
B232PUNVDRH-A @ 100%
120
1 PRS B232PUNVDRH-A @ 50%
B232PUNVDRH-A @ 100%
277
B232PUNVDRH-A @ 50%
B232PUNVDRL-A @ 100%
120
B232PUNVDRL-A @ 50%
B232PUNVDRL-A @ 100%
277
B232PUNVDRL-A @ 50%
DEMANDflex
T8
•
•
•
•
DEMANDflex®
niversal DCL® Dimming
U
Programmed Rapid Start
1, 2, 3, & 4 Lamp Applications
Visit www.unvlt.com for a comprehensive
description of the DCL system and
DEMANDflex ballasts
FOR (1), (2), (3) & (4) LAMPS
Certification Line Input Power Ballast Ballast
Lamp
Min. F/C
Starting Line
Catalog Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method Volts
Number
c (Amps) (Watts) (PF)
(BF) Factor (BEF) %
Temp Diag. Dim.
F25T8 - One Lamp Applications
B232PUNVDR-A @ 100%
120
B232PUNVDR-A @ 50%
B232PUNVDR-A @ 100%
277
B232PUNVDR-A @ 50%
B232PUNVDRH-A @ 100%
120
1 PRS B232PUNVDRH-A @ 50%
B232PUNVDRH-A @ 100%
277
B232PUNVDRH-A @ 50%
B232PUNVDRL-A @ 100%
120
B232PUNVDRL-A @ 50%
B232PUNVDRL-A @ 100%
277
B232PUNVDRL-A @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.19
0.10
0.08
0.05
0.25
0.12
0.11
0.06
0.15
0.08
0.07
0.04
22
12
22
13
30
14
30
15
18
10
18
10
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .95
0.87
0.35
0.88
0.35
1.16
0.50
1.16
0.50
0.69
0.18
0.69
0.18
4.00
2.93
3.95
2.82
3.87
3.57
3.81
3.33
3.85
1.84
3.77
1.75
< 10
< 15
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B232PUNVDR-A @ 100%
120
B232PUNVDR-A @ 50%
B232PUNVDR-A @ 100%
277
B232PUNVDR-A @ 50%
B232PUNVDRH-A @ 100%
120
2 PRS B232PUNVDRH-A @ 50%
B232PUNVDRH-A @ 100%
277
B232PUNVDRH-A @ 50%
B232PUNVDRL-A @ 100%
120
B232PUNVDRL-A @ 50%
B232PUNVDRL-A @ 100%
277
B232PUNVDRL-A @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.36
0.19
0.16
0.09
0.46
0.21
0.20
0.10
0.30
0.15
0.13
0.07
44
23
43
23
55
26
55
26
36
18
35
18
> .95
> .95
> .95
> .95
> .95
> .90
> .95
> .90
> .95
> .95
> .95
> .95
0.87
0.35
0.87
0.35
1.15
0.50
1.15
0.50
0.69
0.19
0.69
0.19
2.01
1.56
2.05
1.53
2.09
1.92
2.08
1.92
1.93
1.06
1.95
1.03
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B332PUNVDR-A @ 100%
120
B332PUNVDR-A @ 50%
B332PUNVDR-A @ 100%
277
B332PUNVDR-A @ 50%
B332PUNVDRL-A @ 100%
120
3 PRS B332PUNVDRL-A @ 50%
B332PUNVDRL-A @ 100%
277
B332PUNVDRL-A @ 50%
B332PUNVDRH-E @ 100%
120
B332PUNVDRH-E @ 50%
B332PUNVDRH-E @ 100%
277
B332PUNVDRH-E @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.55
0.27
0.24
0.13
0.47
0.24
0.21
0.11
0.74
0.35
0.33
0.16
66
33
65
32
56
28
55
29
89
42
89
43
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .95
0.87
0.35
0.87
0.35
0.71
0.23
0.71
0.23
1.17
0.50
1.17
0.50
1.32
1.06
1.34
1.09
1.27
0.81
1.29
0.80
1.31
1.19
1.31
1.16
< 10
< 10
< 10
< 15
< 10
< 10
< 10
< 10
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12c
12c
12c
12c
12c
12c
12c
12c
12d
12d
12d
12d
-A
-A
-A
-A
-A
-A
-A
-A
-E
-E
-E
-E
B432PUNVDR-E @ 100%
120
B432PUNVDR-E @ 50%
B432PUNVDR-E @ 100%
277
4 PRS B432PUNVDR-E @ 50%
B432PUNVDRL-E @ 100%
120
B432PUNVDRL-E @ 50%
B432PUNVDRL-E @ 100%
277
B432PUNVDRL-E @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.75
0.37
0.33
0.17
0.61
0.31
0.27
0.15
90
44
89
44
73
37
72
38
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .90
0.89
0.35
0.89
0.35
0.71
0.21
0.71
0.21
0.99
0.80
1.00
0.80
0.97
0.56
0.98
0.56
< 10
< 15
< 10
< 15
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12e
12e
12e
12e
12e
12e
12e
12e
-E
-E
-E
-E
-E
-E
-E
-E
F25T8 - Two Lamp Applications
F25T8 - Three Lamp Applications
DEMANDflex
F25T8 - Four Lamp Applications
See page 2-7 for Dimensions and Wiring Diagrams
PAGE 2-4
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
DEMANDflex®
•
•
•
•
FOR (1), (2), (3) & (4) LAMPS
DEMANDflex
Universal DCL® Dimming
Programmed Rapid Start
1, 2, 3, & 4 Lamp Applications
Visit www.unvlt.com for a comprehensive
description of the DCL system and
DEMANDflex ballasts
T8
Certification Line Input Power Ballast Ballast
Lamp
Min. F/C
Starting Line
Catalog Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method Volts
Number
c (Amps) (Watts) (PF)
(BF) Factor (BEF) %
Temp Diag. Dim.
F17T8 - One Lamp Applications
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.14
0.08
0.06
0.04
0.18
0.09
0.09
0.05
0.11
0.09
0.05
0.04
16
10
17
10
22
11
22
11
13
10
13
11
> .95
> .95
> .95
> .85
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .85
0.92
0.27
0.92
0.27
1.15
0.50
1.15
0.50
0.70
0.20
0.70
0.20
5.65
2.81
5.48
2.66
5.23
4.63
5.23
4.55
5.47
1.98
5.22
1.87
< 10
< 15
< 10
< 15
< 10
< 15
< 10
< 15
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
12a
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B232PUNVDR-A @ 100%
120
B232PUNVDR-A @ 50%
B232PUNVDR-A @ 100%
277
B232PUNVDR-A @ 50%
B232PUNVDRH-A @ 100%
120
2 PRS B232PUNVDRH-A @ 50%
B232PUNVDRH-A @ 100%
277
B232PUNVDRH-A @ 50%
B232PUNVDRL-A @ 100%
120
B232PUNVDRL-A @ 50%
B232PUNVDRL-A @ 100%
277
B232PUNVDRL-A @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.25
0.13
0.13
0.06
0.32
0.16
0.14
0.07
0.21
0.12
0.09
0.06
30
16
30
16
38
19
39
19
25
15
25
15
> .95
> .95
> .95
> .95
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .95
0.90
0.27
0.90
0.27
1.16
0.50
1.16
0.50
0.69
0.19
0.69
0.19
3.00
1.72
3.00
1.67
3.05
2.63
2.97
2.63
2.78
1.29
2.76
1.24
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 15
< 10
< 10
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
12b
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
-A
B332PUNVDR-A @ 100%
120
B332PUNVDR-A @ 50%
B332PUNVDR-A @ 100%
277
B332PUNVDR-A @ 50%
B332PUNVDRL-A @ 100%
120
3 PRS B332PUNVDRL-A @ 50%
B332PUNVDRL-A @ 100%
277
B332PUNVDRL-A @ 50%
B332PUNVDRH-E @ 100%
120
B332PUNVDRH-E @ 50%
B332PUNVDRH-E @ 100%
277
B332PUNVDRH-E @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.40
0.20
0.18
0.10
0.33
0.18
0.15
0.09
0.54
0.25
0.24
0.12
48
24
48
24
40
22
40
23
65
32
65
32
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .85
> .95
> .95
> .95
> .90
0.89
0.36
0.89
0.36
0.73
0.23
0.73
0.23
1.19
0.51
1.19
0.51
1.86
1.51
1.86
1.51
1.83
1.05
1.83
1.02
1.83
1.59
1.84
1.59
< 10
< 10
< 10
< 15
< 10
< 10
< 10
< 15
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12c
12c
12c
12c
12c
12c
12c
12c
12d
12d
12d
12d
-A
-A
-A
-A
-A
-A
-A
-A
-E
-E
-E
-E
B432PUNVDR-E @ 100%
120
B432PUNVDR-E @ 50%
B432PUNVDR-E @ 100%
277
4 PRS B432PUNVDR-E @ 50%
B432PUNVDRL-E @ 100%
120
B432PUNVDRL-E @ 50%
B432PUNVDRL-E @ 100%
277
B432PUNVDRL-E @ 50%
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
0.53
0.27
0.24
0.13
0.43
0.26
0.20
0.12
64
32
63
32
52
31
52
31
> .95
> .95
> .95
> .90
> .95
> .95
> .95
> .90
0.91
0.35
0.91
0.35
0.73
0.21
0.73
0.21
1.42
1.09
1.44
1.09
1.41
0.69
1.41
0.67
< 10
< 15
< 10
< 15
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
32/0
32/0
32/0
32/0
12e
12e
12e
12e
12e
12e
12e
12e
-E
-E
-E
-E
-E
-E
-E
-E
F17T8 - Two Lamp Applications
F17T8 - Three Lamp Applications
F17T8 - Four Lamp Applications
See page 2-7 for Dimensions and Wiring Diagrams
FOR MORE INFORMATION CALL
PAGE 2-5
1-800-BALLAST
(225-5278)
DEMANDflex
B232PUNVDR-A @ 100%
120
B232PUNVDR-A @ 50%
B232PUNVDR-A @ 100%
277
B232PUNVDR-A @ 50%
B232PUNVDRH-A @ 100%
120
1 PRS B232PUNVDRH-A @ 50%
B232PUNVDRH-A @ 100%
277
B232PUNVDRH-A @ 50%
B232PUNVDRL-A @ 100%
120
B232PUNVDRL-A @ 50%
B232PUNVDRL-A @ 100%
277
B232PUNVDRL-A @ 50%
DEMANDflex
T5, T5HO & TT5
•
•
•
•
•
niversal DCL® Dimming
U
Programmed Rapid Start
2 Lamp Applications for T5HO
1 & 2 Lamp Applications for T5
Visit www.unvlt.com for a comprehensive
description of the DCL system and DEMANDflex ballasts
DEMANDflex®
FOR T5 & T5HO LAMPS
Certification
Lamp
Line
Input Power Ballast
Ballast
Min. F/C
Starting Line
Catalog Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method Volts
Number
c (Amps) (Watts) (PF)
(BF) Factor (BEF) %
Temp Diag. Dim.
F28T5 - One Lamp Applications
B128PUNVDRH-D @ 100%
120
1 PRS B128PUNVDRH-D @ 50%
B128PUNVDRH-D @ 100%
277
B128PUNVDRH-D @ 50%
•
•
•
•
•
•
•
•
0.32
0.16
0.14
0.08
37
19
37
19
> .99
> .99
> .96
> .88
1.15
0.38
1.15
0.38
3.11
2.00
3.11
2.00
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
12g
12g
12g
12g
-D
-D
-D
-D
B228PUNVDRH-D @ 100%
120
2 PRS B228PUNVDRH-D @ 50%
B228PUNVDRH-D @ 100%
277
B228PUNVDRH-D @ 50%
•
•
•
•
•
•
•
•
0.60
0.30
0.25
0.13
72
36
70
35
> .95
> .95
> .95
> .95
1.15
0.51
1.15
0.50
1.60
1.42
1.64
1.43
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
12f
12f
12f
12f
-D
-D
-D
-D
B228PUNVDRH-D @ 100%
120
2 PRS B228PUNVDRH-D @ 50%
B228PUNVDRH-D @ 100%
277
B228PUNVDRH-D @ 50%
•
•
•
•
•
•
•
•
0.75
0.38
0.31
0.17
90
45
87
44
> .95
> .95
> .95
> .95
1.13
0.51
1.13
0.51
1.26
1.13
1.30
1.16
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
12f
12f
12f
12f
-D
-D
-D
-D
B128PUNVDRH-D
120
1 PRS B128PUNVDRH-D
B128PUNVDRH-D
277
B128PUNVDRH-D
@ 100%
@ 50%
@ 100%
@ 50%
•
•
•
•
•
•
•
•
0.25
0.13
0.12
0.07
28
15
28
15
> .99
> .99
> .94
> .84
1.15
0.38
1.15
0.38
4.11
2.53
4.11
2.53
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
12g
12g
12g
12g
-D
-D
-D
-D
B228PUNVDRH-D
120
2 PRS B228PUNVDRH-D
B228PUNVDRH-D
277
B228PUNVDRH-D
@ 100%
@ 50%
@ 100%
@ 50%
•
•
•
•
•
•
•
•
0.47
0.23
0.20
0.11
56
28
55
28
> .95
> .95
> .95
> .90
1.16
0.51
1.16
0.51
2.07
1.82
2.11
1.82
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
12f
12f
12f
12f
-D
-D
-D
-D
B228PUNVDRH-D
120
2 PRS B228PUNVDRH-D
B228PUNVDRH-D
277
B228PUNVDRH-D
@ 100%
@ 50%
@ 100%
@ 50%
•
•
•
•
•
•
•
•
0.34
0.16
0.15
0.08
40
19
40
20
> .95
> .95
> .95
> .85
1.17
0.52
1.17
0.52
2.93
2.74
2.93
2.60
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
12f
12f
12f
12f
-D
-D
-D
-D
B254PUNVDR-D @ 100%
120
2 PRS B254PUNVDR-D @ 50%
B254PUNVDR-D @ 100%
277
B254PUNVDR-D @ 50%
•
•
•
•
•
•
•
•
1.00
0.50
0.43
0.22
120
60
120
60
> .95
> .95
> .95
> .90
1.00
0.45
1.00
0.45
0.83
0.75
0.83
0.75
< 10
< 10
< 10
< 10
0/-18
0/-18
0/-18
0/-18
12f
12f
12f
12f
-D
-D
-D
-D
B254PUNVDR-D @ 100%
120
2 PRS B254PUNVDR-D @ 50%
B254PUNVDR-D @ 100%
277
B254PUNVDR-D @ 50%
•
•
•
•
•
•
•
•
0.90
0.41
0.39
0.19
108
50
106
50
> .95
> .95
> .95
> .95
1.06
0.57
1.06
0.57
0.98
1.14
1.00
1.14
< 10
< 10
< 10
< 10
0/-18
0/-18
0/-18
0/-18
12f
12f
12f
12f
-D
-D
-D
-D
B254PUNVDR-D
120
2 PRS B254PUNVDR-D
B254PUNVDR-D
277
B254PUNVDR-D
@ 100%
@ 50%
@ 100%
@ 50%
•
•
•
•
•
•
•
•
0.97
0.47
0.42
0.21
115
57
113
57
> .95
> .95
> .95
> .95
1.10
0.63
1.11
0.63
0.96
1.11
0.98
1.11
< 10
< 10
< 10
< 10
0/-18
0/-18
0/-18
0/-18
12f
12f
12f
12f
-D
-D
-D
-D
B254PUNVDR-D
120
2 PRS B254PUNVDR-D
B254PUNVDR-D
277
B254PUNVDR-D
@ 100%
@ 50%
@ 100%
@ 50%
•
•
•
•
•
•
•
•
0.88
0.41
0.38
0.19
106
49
104
48
> .95
> .95
> .95
> .95
1.04
0.56
1.04
0.56
0.98
1.14
1.00
1.17
< 10
< 10
< 10
< 10
0/-18
0/-18
0/-18
0/-18
12f
12f
12f
12f
-D
-D
-D
-D
B254PUNVDR-D @ 100%
120
2 PRS B254PUNVDR-D @ 50%
•
•
•
•
0.88
0.41
106
49
> .95
> .95
1.04
0.56
0.98
1.14
< 10
< 10
0/-18
0/-18
12f
12f
-D
-D
F28T5 - Two Lamp Applications
F35T5 - Two Lamp Applications
F21T5 - One Lamp Applications
F21T5 - Two Lamp Applications
F14T5 - Two Lamp Applications
F54T5HO - Two Lamp Applications
FT55W/2G11 - Two Lamp Applications
DEMANDflex
FT50W/2G11 - Two Lamp Applications
FC55T5-55W - Two Lamp Applications
F21T5-55W - One Lamp Application
See page 2-7 for Dimensions and Wiring Diagrams
PAGE 2-6
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
DEMANDflex
T8
DEMANDflex®
WIRING DIAGRAMS
Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances
Ballast case must be grounded. A star washer or other paint penetrating device is required.
Wiring Diagram 12a
Wiring Diagram 12e
Wiring Diagram 12b
Wiring Diagram 12f
Wiring Diagram 12c
Wiring Diagram 12g
Wiring Diagram 12d
Overall Dimensions
Draw #
L
9.50”
16.88”
16.88”
-A, -E
1.70”
1.18”
1.82”
Mounting Dimensions
H
M
X
1.18”
1.00”
1.18”
8.89”
16.20”
16.28”
1.69”
—
—
-D
FOR MORE INFORMATION CALL
PAGE 2-7
1-800-BALLAST
(225-5278)
DEMANDflex
-A
-D
-E
W
DCL Controls
DCL CONTROLS
MODEL
LP12DCLUNV-xx**
SC20DCLUNV**
MC20DCLUNV**
RSMDCL51
WTPDCL51∆
WPS5527K
DESCRIPTION
Circuit Control Panel
Single Circuit Controller
Open Style Single Circuit Controller
Contact Interface Controller
Time/Photo Controller
Photo Sensor for WTPDCL
LP12DCLUNV-xx
Dimensions Mounting
Length 32” 24”
Width 20” 16”
Depth 4.3”
The same cabinet size is used
for the four different panels. the
quantity of individual controllers
installed is determined by the
model number.
xx = number of circuits (03 - 12)
* For additional lighting system controllers, contact Universal Lighting.
** Modbus versions of these controls are available.
∆ Consult Universal for configuration options.
SC20DCLUNV
SC20DCLUNV
Single Circuit Controller
MOUNTING PATTERN
Dimensions
Length 9.66”
Width 3.98”
Depth 3.21”
MC20DCLUNV
Open Style,
Single Circuit Controller
Circuit control panels are used to send commands down the lighting circuit to the DemandFlex ballasts. The
LP12DCLUNV-xx panels are available with 3 to 12 integral circuit control modules. If more than 12 circuits are
being controlled, additional panels can be used.
The SC20DCLUNV is used when there are a small number of circuits or space limitations prevent the use of
an LP12DCLUNV panel.
One RSMDCL51 or WTPDCL51 can control up to 63 circuits. If more than 63 circuits are to be controlled, an
RSMDCL can be connected in parallel with either controller for another 63 circuits.
Contact Closure Interface Control
DCL Controls
Stand Alone Time Clock/Photo Cell Control
The WTPDCL51 controller provides time of day
scheduling and can also be connected to the
WPS5527K Photo Cell for daylight harvesting.
Manual override switches are also available.
The RSMDCL51 controller integrates with external
relays or switches to translate commands to the DCL
system. This controller can be used to interface with
building automation systems, PLC’s, or switches.
These systems may also incorporate photo cells for
dayllight harvesting.
Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances
FOR MORE INFORMATION CALL
PAGE 2-8
1-800-BALLAST
(225-5278)
Controllable Lighting
Fluorescent Energy
Management / Dimming
Ballasts and Controls
The effective dimming of fluorescent lights delivers a wide range
of benefits: greater control of workspace lighting, ability to create a mood, energy savings, and more.
Universal Lighting Technologies (“Universal”) line of electronic
dimming ballasts and controls lets you accomplish these goals
with a variety of products to suit your dimming needs. From
light level switching and analog dimming to digital dimming and
controls, Universal has the products and technologies to meet
today’s dimming requirements for energy savings and controllable lighting.
Fluorescent Dimming
Universal Lighting Technologies is a member of the Panasonic Group
Product Overview
Universal offers five different families of dimming products that can be used for today’s dimming
requirements for architectural lighting control and energy management applications:
BallaStar: Step-dimming
SuperDim: Analog (0 to 10 volt) dimming
DaliPRO: Digital dimming with the DALI protocol
DaliPRO Premium: Parallel-lamp digital dimming (DALI)
VariPRO: Parallel-lamp analog dimming
LevelPRO: Parallel-lamp step dimming
BallaStar® Light Level Switching (S30 & S50)
Our Ballastar® line offers two options of light level switching (either 100/50% or 100/60/30%).
That makes BallaStar® a cost-effective solution for both new construction and retrofits.
Universal BallaStar® ballasts are designed to ensure optimum lamp performance. Their Lamp Current
Crest Factors are well below the maximum 1.7 ANSI standard — and they start the lamps according to ANSI
recommendations at all dimming levels. Both of these important design parameters ensure optimum lamp
performance. In addition, BallaStar® ballasts actually increase cathode heating when dimming to maintain
the cathode’s proper temperature, which enhances lamp life and performance stability.
Fluorescent Dimming
• 1, 2, & 3 lamp models for 120 & 277 volt
• Switches to preset light levels, keeping all lamps illuminated
• Eliminates the dark spots associated with inboard/outboard configurations
• Connects with two line voltage power leads
– Wires the same as an inboard/outboard fixture
– No special controls required; uses two wall switches
• Meets all ASHRAE 90.1 and California Title 24 requirements for lighting control
• THD <10%
• Lower installed costs; less wiring and equipment required
Ballastar® Light Level Switching for ultimate control.
PAGE 2-10
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Product Overview
SuperDim® Analog Dimming Ballasts
Universal Lighting’s new SuperDim® analog dimming ballasts are a cost-effective choice for large scale
dimming applications. SuperDim® ballasts are designed for T8 and T5 linear fluorescent lamps and T4
4-pin quad and triple compact fluorescent lamps.
SuperDim® ballasts are compatible with a wide range of 0 – 10 volt controls and can be connected
to photocells for daylight harvesting. The resulting energy savings makes it easy to adhere to even
the strictest energy requirements, including California Title 24 and ASHRAE 90.1.
These versatile ballasts offer programmed rapid start technology for longer lamp life. They also
incorporate end-of-lamp-life shutdown circuits, low profile designs and < 10% THD at full bright.
Features and Benefits
• Ideal for T8 and T5 linear fluorescent lamps and T4 4-pin
quad and triple compact fluorescent lamps
• Compatible with most 0 – 10 volt manufactured controls
• Daylight harvesting options with photocells for maximum
energy savings
• Programmed rapid start technology maximizes lamp life
• Low profile design for fixture design flexibility
• End-of-lamp-life shutdown circuitry ensures safe operation
• < 10% THD at full bright
• Universal input voltage (120–277 volts) for installation flexibility
Fluorescent Dimming
PAGE 2-11
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Product Overview
DaliPROTM Digital Dimming Ballasts for DALI
DaliPROTM ballasts from Universal Lighting let you take full advantage of the Digital Addressable
Lighting Interface (DALI) standard...and that means greater flexibility, greater savings.
The DALI Advantage
The DALI protocol uses a 2-wire control loop to communicate with up to 64 ballasts. Broadcast,
group and individual addressing is used to control light levels, recall scenes and poll ballast status.
Many DALI-compatible controls are now available from established manufacturers; and new varieties
are being developed daily.
DaliPRO Features and Benefits
• Available for T8, T5, T5HO and compact fluorescent lamps
• Provides dimming down to 1% for linear lamps and 3% for compact fluorescent lamps
• Lets you adapt instantly to additions or changes in lighting design without ballast or fixture rewiring
• Offers status/performance data, including lamp status and system faults
• Low profile designs for easy installation in a wide variety of fixtures
• Universal input voltage (120– 277 volts)
– Installer-friendly; ensures you have the right ballast every time
– Reduces inventory costs and requirements
• End-of-Lamp Life Shutdown with auto reset circuitry for safe operation
• Programmed Rapid Start for long lamp life
Fluorescent Dimming
DaliPRO Premium
DaliPRO Premium performs the same as standard DaliPRO but with the additonal feature of parallel-lamp
operation.
PAGE 2-12
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Product Overview
VariPRO & LevelPRO Parallel-Lamp Dimming Ballasts
Universal Lighting Technologies’ parallel-lamp dimming families combine new performance features with maximum
energy savings. These ballasts provide parallel-lamp operation – when one lamp fails the other remains lit. This prevents
fixture from going dark and simplifies troubleshooting and maintenance operations.
Performance
• Total Harmonic Distortion (THD) < 10%
• Power Factor (PF) > 10%
• NEMA Premium
• RoHS Compliant
General Features and Benefits
• Quick Programmed Start Technology
– Start time less than 700ms
– Maintains long lamp life in frequently switched applications
• High Efficiency Operation
– Complies with CEE and NEMA Premium
– Incorporates Anti-Striation circuitry
– Designed for use with 30, 28, and 25 Watt energy saving lamps
• True Parallel-Lamp Operation
– When one lamp fails, other lamps continue to operate normally
– Simplifies fixture troubleshooting
• Universal Input Voltage and 347 Models
VariPRO Features and Benefits
• Analog (0-10V) Dimming Control
– Compatible with industry standard
0-10V controls and photocells
– Ideal for daylight harvesting
TM
LevelPRO Features and Benefits
• Line Voltage Step Dimming Control
– Uses standard wall switches
– Provides even fixture illumination
Fluorescent Dimming
PAGE 2-13
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
Although dimming ballasts follow similar installation and operating guidelines as electronic ballasts, application notes and
other training materials, written specifically for dimming ballasts, are provided on www.unvlt.com website.
SAFETY
Analog dimming ballasts are controlled by using a low voltage 0-10VDC control circuit. Care should be taken to insure that the
line voltage (AC) wires are not connected to the low voltage DC wires. SuperDim® Electronic dimming ballasts have a protection circuit that will sense if the ballast has been connected in this manner and not harm the ballast.
Light Level Switching Installation Note
The two power leads for the light level switching ballasts must be connected to the same power circuit. The leads should
connect to separate switches or relays for control of the light level switching operation. Connection of the input leads to separate power circuits can damage the ballasts.
Note:
Do not connect any other ballast to the load side of the switches controlling the switched
dimming ballast.
Compatible Dimming Controls
For a listing of compatible controls for universal analog ballasts, please consult catalog page 3-7, or call 1-800-BALLAST
or check out the Dimming and Controls section of our home page at www.unvlt.com.
Fusing
Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts.
For a comprehensive list of appropriate fuses, contact our Technical Engineering Services (TES) Department at 1-800-BALLAST.
Detailed Operating Instructions
Fluorescent Dimming
For additional information on all of Universal’s dimming products, consult our website at www.unvlt.com. Application notes,
dimming brochures and online training is available
PAGE 2-14
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Controls For Analog Dimming Ballasts
Manual Controls, Photo-Sensors, Wall Stations & Hand Held Remotes
Manufacturer
Website
Telephone
Cooper Controls
www.coopercontrol.com
(800) 553-3879
DimOnOff
www.dimonoff.com
(418) 682-3636
Douglas Lighting Controls, Inc
www.douglaslightingcontrol.com
(604) 873-2797
HUNT Dimming
www.huntdimming.com
(970) 484-9048
Lehigh Electric Products Co.
www.lehighdim.com
(610) 395-3386
Leviton
www.leviton.com/les
1-800-736-6682
Lutron
www.lutron.com/universal
(888) LUTRON1 - Sales
(800) 523-9466 - Technical Support
NexLight
www.nexlight.com
(218) 828-3700
The Watt Stopper, Inc
www.wattstopper.com
(800) 879-8585
Marlin Controls
www.marlincontrols.com
(800) 788-5750
Sensor Switch, Inc.
www.sensorswitch.com
(800) 727-7483
(800) PASSIVE
Touch-Plate Lighting Controls
www.touchplate.com
(260) 426-1565
Manufacturer
Website
Telephone
Cooper Controls
www.coopercontrol.com
(800) 553-3879
DimOnOff
www.dimonoff.com
(418) 682-3636
Douglas Lighting Controls, Inc
www.douglaslightingcontrol.com
(604) 873-2797
Lehigh Electric Products Co.
www.lehighdim.com
(610) 395-3386
Lutron
www.lutron.com/universal
(888) LUTRON1 - Sales
(800) 523-9466 - Technical Support
NexLight
www.nexlight.com
(218) 828-3700
Marlin Controls
www.marlincontrols.com
(800) 788-5750
Sensor Switch, Inc.
www.sensorswitch.com
(800) 727-7483
(800) PASSIVE
Touch-Plate Lighting Controls
www.touchplate.com
(260) 426-1565
Occupancy Sensors
Systems: Control Panels, Building Management Systems, etc
Website
Telephone
DimOnOff
www.dimonoff.com
(418) 682-3636
Douglas Lighting Controls, Inc
www.douglaslightingcontrol.com
(604) 873-2797
Cooper Controls
www.coopercontrol.com
(800) 553-3879
HUNT Dimming
www.huntdimming.com
(970) 484-9048
Lehigh Electric Products Co.
www.lehighdim.com
(610) 395-3386
Leviton
www.leviton.com/les
1-800-736-6682
Lutron
www.lutron.com/universal
(888) LUTRON1 - Sales
(800) 523-9466 - Technical Support
NexLight
www.nexlight.com
(218) 828-3700
The Watt Stopper, Inc
www.wattstopper.com
(800) 879-8585
Marlin Controls
www.marlincontrols.com
(800) 788-5750
Touch-Plate Lighting Controls
www.touchplate.com
(260) 426-1565
The information listed above is provided by Universal Lighting Technologies to facilitate development of dimming systems. All information has been provided by the controls manufacturers, and Universal
Lighting Technologies makes no guarantee regarding its accuracy. The reader is advised to contact these, and other manufacturers of analog dimming systems, to obtain application advice, to determine
availability of the controls listed above, and to learn about other controls that may be offered.
Data is subject to change without notice.
PAGE 2-15
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent Dimming
Manufacturer
DaliPRO® DIMMING BALLASTS
DaliPRO®
Lamp
Starting
Qty. Method
F1728
1
PRS
2
PRS
F32T8 *
1
PRS
2
PRS
F14T5
1
PRS
2
PRS
F21T5
1
PRS
Fluorescent Dimming
2
PRS
F28T5 *
1
PRS
Line
Catalog
Volts
Number
PRS
2
PRS
Dim.
<10%
32/0
1
-A
2.69
<10%
32/0
2
-A
1.00
2.90
<10%
32/0
1
-A
1.00
1.52
<10%
32/0
2
-A
>.95
1.00
5.61
<10%
50/10
1
-D
>.95
1.00
3.02
<10%
50/10
2
-D
25
24
45
45
>.95
1.00
4.15
<10%
50/10
1
-D
>.95
1.00
3.02
<10%
50/10
2
-D
32
32
62
61
>.95
1.00
3.13
<10%
50/10
1
-D
B228PUNVDV3-D
0.29
0.13
0.52
0.22
>.95
1.00
1.64
<10%
50/10
2
-D
B135PUNVDV3-D
0.35
0.15
41
41
>.95
1.00
2.45
<10%
50/10
1
-D
C213UNVDV3ME
0.15
0.07
0.27
0.12
18
18
32
32
>.90
1.00
5.56
<15%
32/0
3
-ME
>.95
1.00
3.17
<15%
32/0
4
-ME
0.20
0.09
0.35
0.15
23
22
45
43
>.90
1.00
4.55
<10%
32/0
3
-ME
>.95
1.00
2.36
<10%
32/0
4
-ME
0.25
0.11
0.44
0.19
31
29
51
50
>.95
1.00
2.00
<10%
32/0
3
-ME
>.95
1.00
3.52
<10%
32/0
4
-ME
0.26
0.12
0.58
0.26
32
33
71
70
>.95
1.00
<10%
32/0
3
-ME
>.95
1.00
3.10
1.41
1.43
<10%
0/-18
4
DP2
0.43
0.19
0.82
0.36
47
45
92
91
>.95
1.00
<10%
0/-18
3
DP2
>.95
1.00
<10%
0/-18
4
DP2
0.37
0.16
0.83
0.37
45
44
97
94
>.95
1.00
<10%
0/-18
5
DP1
>.95
1.00
<10%
0/-18
6
DP1
120
277
120
277
B132PUNVDV3-A
120
277
120
277
B114PUNVDV3-D
B232PUNVDV3-A
B232PUNVDV3-A
B214PUNVDV3-D
120
277
120
277
B128PUNVDV3-D
120
277
120
277
B128PUNVDV3-D
CFTR42W/G24q
120
1
PRS
277
120
2
PRS
277
1
Wiring
Diag.
B132PUNVDV3-A
2
PRS
F35T5
120
1
277
CFQ13W/G24q
120
1
PRS
277
120
2
PRS
277
CFQ18W/G24q
120
1
PRS
277
120
2
PRS
277
CFQ26W/G24q
120
1
PRS
277
120
2
PRS
277
CFTR32W/G24q
120
1
PRS
277
120
2
PRS
277
FT40W/2G11
Min. F/C
Start
Temp
120
277
120
277
120
277
120
277
B228PUNVDV3-D
C213UNVDV3ME
C218UNVDV3ME
C218UNVDV3ME
C226UNVDV3ME
C226UNVDV3ME
C226UNVDV3ME
C232PUNVDV3
C226UNVDV3ME
C242PUNVDV3
C140PUNVDV3
C240PUNVDV3
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor
(PF)
Ballast
Factor
(BF)
0.18
0.08
0.33
0.14
21
20
38
38
>.95
1.02
5.10
>.98
1.01
0.30
0.13
0.58
0.25
35
35
67
66
>.95
>.98
0.15
0.07
0.28
0.13
18
18
33
33
0.23
0.10
0.40
0.17
* Consult Specification Sheets at www.unvlt.com for additional lamp applications
Ballast
Efficacy
THD
Factor (BEF)
%
2.13
2.22
1.09
1.10
2.22
2.27
1.03
1.06
See page 2-22 for Dimensions
and Wiring Diagrams
STARTING METHOD LEGEND
PAR-PRS = Parallel Programmed Start
PAGE 2-16
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
DaliPRO® Premium DIMMING BALLASTS
DaliPRO®
Premium
PARALLEL LAMP
DIMMING
Lamp
Starting
Qty. Method
F1728
1
PRS
Line
Catalog
Volts
Number
Min. F/C
Start
Temp
Wiring
Diag.
Dim.
<10%
32/0
20
-A
5.13
5.13
5.13
2.84
<10%
<20%
<20%
<10%
32/0
32/0
32/0
32/0
20
20
20
2
-D
-A
-D
-A
1.02
1.00
1.00
2.84
2.78
2.78
<10%
<10%
<10%
32/0
32/0
32/0
2
2
2
-D
-A
-D
>.98
1.00
2.80
<10%
32/0
20
-A
>.98
>.95
>.95
>.99
1.00
1.00
1.00
1.00
2.85
2.87
2.87
1.53
<10%
<10%
<10%
<10%
32/0
32/0
32/0
32/0
20
20
20
2
-D
-A
-D
-A
>.99
>.95
>.95
1.00
1.00
1.00
1.53
1.54
1.54
<10%
<10%
<10%
32/0
32/0
32/0
2
2
2
-D
-A
-D
19
19
19
19
19
19
35
35
35
35
35
35
>.95
1.01
5.19
<10%
50/10
20
-A
>.95
>.90
>.90
>.98
1.01
1.01
1.01
1.01
5.19
5.27
5.27
2.92
<10%
<20%
<10%
<10%
50/10
50/10
50/10
50/10
20
20
20
2
-D
-A
-D
-A
>.98
>.95
>.95
1.01
1.01
1.01
2.92
2.93
2.93
<10%
<10%
<10%
50/10
50/10
50/10
2
2
2
-D
-A
-D
35
34
35
34
34
34
62
61
62
61
64
64
>.98
1.00
2.95
<10%
50/10
20
-A
>.98
>.95
>.95
>.99
1.00
1.00
1.00
1.00
2.95
2.94
2.94
1.63
<10%
<10%
<10%
<10%
50/10
50/10
50/10
50/10
20
20
20
2
-D
-A
-D
-A
B228PUDV3PLD
B228P3DV3PLA
B228P3DV3PLD
0.30
0.13
0.29
0.12
0.10
0.10
0.56
0.24
0.56
0.24
0.19
0.19
>.99
>.98
>.98
1.00
1.00
1.00
1.63
1.57
1.57
<10%
<10%
<10%
50/10
50/10
50/10
2
2
2
-D
-A
-D
B254PUDV3PLD
B254P3DV3PLD
B254PUDV3PLD
B254P3DV3PLD
0.51
0.23
0.18
0.94
0.41
0.33
54
56
58
116
112
109
>.97
>.98
>.99
>.99
1.00
1.00
1.00
1.00
1.85
1.72
0.89
0.92
<10%
<10%
<10%
<10%
32/0
32/0
32/0
32/0
20
20
2
2
-D
-D
-D
-D
B232PUDV3PLA
B232PUDV3PLD
B232P3DV3PLA
B232P3DV3PLD
B232PUDV3PLA
B232PUDV3PLD
B232P3DV3PLA
B232P3DV3PLD
B232PUDV3PLA
B232PUDV3PLD
B232P3DV3PLA
B232P3DV3PLD
B232PUDV3PLA
B232PUDV3PLD
B232P3DV3PLA
B232P3DV3PLD
B228PUDV3PLA
B228PUDV3PLD
B228P3DV3PLA
B228P3DV3PLD
B228PUDV3PLA
B228PUDV3PLD
B228P3DV3PLA
B228P3DV3PLD
B228PUDV3PLA
B228PUDV3PLD
B228P3DV3PLA
B228P3DV3PLD
B228PUDV3PLA
Input
Power
(Watts)
Power
Factor
(PF)
Ballast
Factor
(BF)
0.19
0.08
0.19
0.08
0.07
0.07
0.32
0.14
0.32
0.14
0.11
0.11
20
20
20
20
20
20
37
36
37
36
37
37
>.95
1.02
5.13
>.95
>.95
>.95
>.98
1.02
1.04
1.04
1.02
>.98
>.95
>.95
0.30
0.13
0.31
0.13
0.11
0.11
0.58
0.25
0.58
0.25
0.19
0.19
36
35
36
35
35
35
67
65
67
65
65
65
0.16
0.07
0.16
0.07
0.06
0.06
0.29
0.13
0.29
0.13
0.10
0.10
* Consult Specification Sheets at www.unvlt.com for additional lamp applications
Ballast
Efficacy
THD
Factor (BEF)
%
See page 2-22 for Dimensions
and Wiring Diagrams
STARTING METHOD LEGEND
PAR-PRS = Parallel Programmed Start
PAGE 2-17
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent Dimming
120
277
120
1
PRS
277
1
PRS
347
1
PRS
347
120
2
PRS
277
120
2
PRS
277
2
PRS
347
2
PRS
347
F32T8* (also operates F28T8)
120
1
PRS
277
120
1
PRS
277
1
PRS
347
1
PRS
347
120
2
PRS
277
120
2
PRS
277
2
PRS
347
2
PRS
347
F14T5 (also operates F21T5)
120
1
PRS
277
120
1
PRS
277
1
PRS
347
1
PRS
347
120
2
PRS
277
120
2
PRS
277
2
PRS
347
2
PRS
347
F28T5 (also operates F28T5/ES)
120
1
PRS
277
120
1
PRS
277
1
PRS
347
1
PRS
347
120
1
PRS
277
120
1
PRS
277
1
PRS
347
1
PRS
347
F54T5HO*
120
1
PRS
277
1
PRS
347
120
2
PRS
277
2
PRS
347
Line
Current
(Amps)
SuperDim®
SuperDim® 0-10V DIMMING BALLASTS
0-10V
DIMMING
Please visit www.unvlt.com for the most up to date status
and recent changes to the SuperDim product family.
Fluorescent Dimming
Lamp
Starting Line
Catalog
Qty. Method Volts
Number
F17T8
120
1 PRS
B132PUNVSV3-A
277
120
2 PRS
B232PUNVSV3-A
277
F25T8
120
1 PRS
B132PUNVSV3-A
277
120
2 PRS
B232PUNVSV3-A
277
F32T8
120
1 PRS
B132PUNVSV3-A
277
120
2 PRS
B232PUNVSV3-A
277
F14T5
120
1 PRS
B114PUNVSV3-D
277
120
2 PRS
B214PUNVSV3-D
277
F21T5
120
1 PRS
B128PUNVSV3-D
277
120
2 PRS
B228PUNVSV3-D
277
F28T5
120
1 PRS
B128PUNVSV3-D
277
120
2 PRS
B228PUNVSV3-D
277
F35T5
120
1 PRS
B135PUNVSV3-D
277
CFQ13W/G24q & CFTR13W/Gx24q
120
1 PRS
C213UNVSV3ME
277
120
2 PRS
C213UNVSV3ME
277
CFQ18W/G24q & CFTR18W/Gx24q
120
1 PRS
C218UNVSV3ME
277
120
2 PRS
C218UNVSV3ME
277
CFQ26W/G24q & CFTR26W/Gx24q
120
1 PRS
C226UNVSV3ME
277
120
2 PRS
C226UNVSV3ME
277
CFTR32W/Gx24q
120
1 PRS
C226UNVSV3ME
277
CFTR42W/Gx24q
120
1 PRS
C226UNVSV3ME
277
Line
Input Power Ballast
Min. F/C
Current Power Factor Factor THD Start Wiring
(Amps) (Watts) (PF)
(BF)
%
Temp
Diag.
Dim.
0.13 16
> .97
0.85
0.06 16
0.27 32
> .98
0.85
0.12
32
0.18 22
> .98
0.85
0.08 22
0.38 45
> .99
0.85
0.16 44
0.25
0.11
0.48
0.20
30
> .99
0.88
30
57
> .99
0.88
56
0.14
0.06
0.27
0.11
17
> .97
1.00
17
32
1.00
32 > .97
0.27
0.12
0.39
0.17
25
> .95
25
47
46 > .95
0.21
0.10
0.53
0.22
32
> .99
1.00
32
63
> .99
1.00
61
<10 50/10 7 -A
<10 50/10 8 -A
<10 32/0 7 -D
<10 32/0 8 -D
<10 50/10 7 -D
<10 50/10 8 -D
<10 50/10 7 -D
<15 32/0 9 C11
<10 32/0 10 C11
1.00 <10 32/0 10 C11
34
> .97
34
1.00
0.35 42
0.15 42 > .98
1.00
STARTING METHOD LEGEND
PRS = Programmed Rapid Start
<10 50/10 8 -A
1.00 <10 32/0 9 C11
0.26 28
> .96
1.00
0.10 28
0.44 53
> .99
1.00
0.19 53
0.28
0.12
<10 50/10 7 -A
1.01 <10 50/10 8 -D
0.13 16
> .99
1.00
0.06 30
0.25 16
> .99
1.00
0.11 30
20
20 > .99
39
38 > .99
<10 50/10 8 -A
1.01 <10 50/10 7 -D
0.33 40
> .99
1.00
0.14 39
0.17
0.08
0.33
0.15
<10 50/10 7 -A
<10 32/0 9 C11
<10 32/0 10 C11
<10 32/0 9 C11
<10 32/0 9 C11
See page 2-22 for Dimensions
and Wiring Diagrams
PAGE 2-18
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
BallaSTAR 0-10 VOLT
DIMMING BALLASTS
®
BallaStar®
• Analog Dimming
• Rapid Start
• 1, 2, 3 & 4 Lamp Applications
0-10V
DIMMING
T8 Straight Lamps
FOR (1), (2), (3) & (4) T8 LAMPS
Please visit www.unvlt.com for the most up to date status
and recent changes to the Ballastar 0-10V product family.
T12 U-Shaped Lamps
Lamp
Starting Line
Catalog
Qty. Method
Volts
Number
F25T8 - One Lamp Applications
B132R347V5 @ 100%
1
347
B132R347V5 @ 5%
F32T8 - One Lamp Applications
B132R347V5 @ 100%
1
347
B132R347V5 @ 5%
F32T8 - Two Lamp Applications
B232SR347V5 @ 100%
347
B232SR347V5 @ 5%
2 RS
B232SR347V5 @ 100%
347
B232SR347V5 @ 5%
F32T8 - Three Lamp Applications
B332SR120V5 @ 100%
120
B332SR120V5 @ 5%
3 SER-RS
B332SR277V5 @ 100%
277
B332SR277V5 @ 5%
F32T8 - Four Lamp Applications
B432SR277V5 @ 100%
4 SER/PAR-RS 277
B432SR277V5 @ 5%
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF) Factor (BEF) %
Temp Diag. Dim.
0.08
0.02
26
7
> .99
> .90
0.90
0.05
3.46
0.71
< 10
< 30
50/10
50/10
7
7
ST
ST
0.09
0.02
32
8
> .99
> .90
0.88
0.05
2.75
0.63
< 10
< 20
50/10
50/10
7
7
ST
ST
0.18
0.04
0.18
0.04
62
13
62
13
> .99
> .90
> .99
> .90
0.88
0.05
0.88
0.05
1.42
0.38
1.42
0.38
< 10
< 15
<10
<15
50/10
50/10
50/10
50/10
8
8
8
8
ST
ST
ST
ST
0.77
0.17
0.33
0.07
92
20
92
20
> .99
> .90
> .99
> .90
0.88
0.05
0.88
0.05
0.96
0.25
0.96
0.25
< 10
< 10
< 10
< 15
50/10
50/10
50/10
50/10
17
17
17
17
ST
ST
ST
ST
0.42
0.11
117
27
> .99
> .90
0.88
0.05
0.79
0.19
< 10
< 15
50/10
50/10
16
16
-ZZ
-ZZ
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
See page 2-22 for Dimensions
and Wiring Diagrams
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAGE 2-19
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent Dimming
All models except B232SR347V5 are cULus Listed
B232SR347V5 is CSA Certified
BALLASTAR
LIGHT LEVEL
SWITCHING
BallaSTAR® STEP DIMMING BALLASTS
FOR (1), (2) & (3) T8 LAMPS
• Step Dimming
•R
apid Start
T8 Straight Lamps
• 1 -3 Lamp Applications
Fluorescent Dimming
T12 U-Shaped Lamps
Lamp
Starting Line
Catalog
Qty. Method
Volts
Number
F17T8 - One Lamp Applications
B232PUS50-A @ 100%
120
B232PUS50-A @ 50%
1 PRS
B232PUS50-A @ 100%
277
B232PUS50-A @ 50%
F17T8 - Two Lamp Applications
B232PUS50-A @ 100%
120
B232PUS50-A @ 50%
2
PRS
B232PUS50-A @ 100%
277
B232PUS50-A @ 50%
F25T8 - One Lamp Applications
B232PUS50-A @ 100%
120
B232PUS50-A @ 50%
1 RS
B232PUS50-A @ 100%
277
B232PUS50-A @ 50%
F25T8 - Two Lamp Applications
B232PUS50-A @ 100%
120
B232PUS50-A @ 50%
2 SER-RS
B232PUS50-A @ 100%
277
B232PUS50-A @ 50%
F32T8 - One Lamp Applications
B232PUS50-A @ 100%
1 RS 120
B232PUS50-A @ 50%
B232PUS50-A @ 100%
277
B232PUS50-A @ 50%
F32T8 - Two Lamp Applicationswa
B232SR120S30 @ 100%
120
B232SR120S30 @ 60%
B232SR120S30 @ 30%
B232SR277S30 @ 100%
277
B232SR277S30 @ 60%
2 SER-RS
B232SR277S30 @ 30%
B232PUS50-A @ 100%
120
B232PUS50-A @ 50%
B232PUS50-A @ 100%
277
B232PUS50-A @ 50%
F32T8 - Three Lamp Applications
B332SR120S30 @ 100%
120
B332SR120S30 @ 60%
B332SR120S30 @ 30%
3 SER-RS
B332SR277S30 @ 100%
277
B332SR277S30 @ 60%
B332SR277S30 @ 30%
All models are cULus Listed
Line
Input Power Ballast
Ballast
Min. F/C
Current Power Factor Factor Efficacy THD Start Wiring
(Amps) (Watts) (PF)
(BF) Factor (BEF) %
Temp Diag. Dim.
0.14
0.08
0.08
0.05
16
9
16
9
> .95
> .95
> .70
> .70
0.88
0.29
0.88
0.29
5.50
3.22
5.50
3.22
< 15
< 15
< 15
< 15
32/0
32/0
32/0
32/0
11
11
11
11
-A
-A
-A
-A
0.25
0.14
0.12
0.07
30
16
30
16
> .99
> .98
> .88
> .85
0.87
0.30
0.87
0.30
2.90
1.88
2.90
1.88
< 10
< 15
< 10
< 15
32/0
32/0
32/0
32/0
12
12
12
12
-A
-A
-A
-A
0.21
0.10
0.11
0.06
24
12
24
12
> .95
> .90
> .80
> .80
0.85
0.28
0.85
0.28
3.54
2.33
3.54
2.33
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
11
11
11
11
-A
-A
-A
-A
0.39
0.20
0.18
0.09
46
24
46
24
> .98
> .95
> .98
> .90
0.84
0.28
0.84
0.28
1.83
1.17
1.83
1.17
< 10
< 10
< 10
< 10
32/0
32/0
32/0
32/0
12
12
12
12
-A
-A
-A
-A
0.25
0.12
0.12
0.06
29
14
29
14
> .99
> .98
> .85
> .80
0.88
0.29
0.88
0.29
3.03
2.07
3.03
2.07
< 10
< 10
< 10
< 20
32/0
32/0
32/0
32/0
11
11
11
11
-A
-A
-A
-A
0.52
0.38
0.24
0.23
0.17
0.11
0.48
0.24
0.21
0.11
62
45
28
62
45
28
57
28
56
28
> .99
> .95
> .95
> .99
> .95
> .95
> .99
> .99
> .95
> .90
0.88
0.58
0.27
0.88
0.58
0.27
0.88
0.30
0.88
0.30
1.42
1.29
0.96
1.42
1.29
0.96
1.54
1.07
1.57
1.07
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
50/10
50/10
32/0
32/0
32/0
32/0
12
12
12
12
12
12
12
12
12
12
ST
ST
ST
ST
ST
ST
-A
-A
-A
-A
0.78
0.61
0.40
0.34
0.26
0.16
93
69
43
94
69
43
> .99
> .95
> .95
> .99
> .95
> .95
0.88
0.60
0.30
0.88
0.60
0.30
0.95
0.87
0.70
0.94
0.87
0.70
< 10
< 10
< 10
< 10
< 10
< 10
50/10
50/10
50/10
50/10
50/10
50/10
15
15
15
15
15
15
ST
ST
ST
ST
ST
ST
See page 2-22 for Dimensions and Wiring Diagrams
PAGE 2-20
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
BallaSTAR® STEP DIMMING BALLASTS
FOR T5 LAMPS
BALLASTAR
• Step Dimming
• Programmed Rapid Start
• 2 Lamp Applications
LIGHT LEVEL
SWITCHING
T5 Straight Lamps
All models are cULus Listed
IS = Instant Start
PRS = Programmed Rapid Start
RS = Rapid Start
See page 2-22 for Dimensions and Wiring Diagrams
STARTING METHOD LEGEND
PAR-IS = Parallel Instant Start
PAR-PRS = Parallel Programmed Rapid Start
PAGE 2-21
PAR-RS = Parallel Rapid Start
SER-RS = Series Rapid Start
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent Dimming
Lamp
Line
Input Power Ballast
Ballast
Min. F/C
Starting Line
Catalog Current Power Factor Factor Efficacy THD Start Wiring
Qty. Method
Volts
Number (Amps) (Watts) (PF)
(BF) Factor (BEF) %
Temp Diag. Dim.
F14T5 - Lamp Applications
B214PU115S50A @ 100%
0.17
21 > .95 1.19
5.90
< 15 50/10 11
-A
120
1
PRS
B214PU115S50A @ 50%
0.09
10 > .95 0.40
3.74
< 15 50/10
11
-A
B214PU115S50A @ 100%
0.09
21 > .75 1.19
5.80
< 15 50/10 11
-A
277
B214PU115S50A @ 50%
0.05
10 > .75 0.40
3.50
< 15 50/10
11
-A
B214PU115S50A @ 100%
0.33 37.5 > .95 1.15
3.10
< 10 50/10 12
-A
120
2
PRS
B214PU115S50A @ 50%
0.15
18 > .95 0.40
2.19
< 15 50/10
12
-A
B214PU115S50A @ 100%
0.15
37 > .90 1.15
3.11
< 10 50/10 12
-A
277
B214PU115S50A @ 50%
0.08
19 > .85 0.40
2.14
< 15 50/10
12
-A
B228PU95S50D @ 100%
0.29
35 > .95 1.00
2.86
< 10 50/10 14 -D
120
2
PRS
B228PU95S50D @ 50%
0.13
16 > .95 0.37
2.30
< 10 50/10
14 -D
B228PU95S50D @ 100%
0.13
35 > .95 1.00
2.86
< 10 50/10
14 -D
277
B228PU95S50D @ 50%
0.06
16 > .90 0.37
2.29
< 10 50/10
14 -D
F21T5 - Lamp Applications
B214PU115S50A @ 100%
0.24
29 > .95 1.18
4.09
< 10 50/10 11
-A
120
1
PRS
B214PU115S50A @ 50%
0.12
14 > .95 0.39
2.84
< 15 50/10
11
-A
B214PU115S50A @ 100%
0.12
29 > .85 1.18
4.06
< 15 50/10 11
-A
277
B214PU115S50A @ 50%
0.62
14 > .85 0.40
2.75
< 15 50/10
11
-A
B228PU95S50D @ 100%
0.40
48 > .95 0.99
2.06
< 10 50/10 14 -D
120
2
PRS
B228PU95S50D @ 50%
0.18
21 > .95 0.36
1.73
< 10 50/10
14 -D
B228PU95S50D @ 100%
0.17
47 > .95 0.99
2.10
< 10 50/10 14 -D
277
B228PU95S50D @ 50%
0.08
22 > .95 0.36
1.65
< 10 50/10
14 -D
F28T5 - Lamp Applications
B214PU115S50A @ 100%
0.32
38 > .95 1.15
3.02
< 10
120
50/10
11 -A
1
PRS
B214PU115S50A @ 50%
0.16
19 > .95 0.45
2.37
< 15
B214PU115S50A @ 100%
0.15
38 > .90 1.15
3.07
< 10
277
50/10
11 -A
B214PU115S50A @ 50%
0.08
19 > .85 0.43
2.23
< 15
B228PU95S50D @100%
0.50
58 > .99 0.95
1.64
< 10
120
50/10 14 -D
B228PU95S50D @50%
0.23
28 > .99 0.35
1.25
< 20
2 PRS
B228PU95S50D @100%
0.21
57 > .98 0.95
1.67
< 10
277
50/10 14 -D
B228PU95S50D @50%
0.10
28 > .95 0.35
1.25
< 20
B228PU115S50D @100%
0.59
71 > .99 1.15
1.62
< 10
120
50/10 14 -D
B228PU115S50D @50%
0.29
34 > .99 0.45
1.32
< 10
2 PRS
B228PU115S50D @100%
0.25
69 > .98 1.15
1.67
< 10
277
50/10 14 -D
B228PU115S50D @50%
0.12
34 > .95 0.45
1.32
< 15
º Preliminary Data
Black (hot)
Black (hot)
L
N
White (neutral)
Red
Red
L
N
White (neutral)
Red
Red
DIMENSIONS
& WIRING
Violet (control)
Violet (control)
DA
Blue
DA
Blue
Black (hot)
Line S1
S2
L
N
White (neutral)
Red
Red
L
N
White (neutral)
Red
Red
Violet (control)
Violet (control)
Overall Dimensions
Draw #
L
-A
-D
-C11
ST
-ZZ
DP1
DP2
DA
Blue
DA
Blue
9.50” 1.70”
16.88” 1.18”
4.94”
3.00”
9.50” 2.40”
16.40” 2.40”
18.00” 1.18”
4.95” Black (hot)2.93”
5
L
N
White (neutral)
1.18”
1.00”
1.00”
1.55”
1.50”
1.18”
1.38”
Red
Red
Violet (control)
DA
Blue
DA
Blue
5
Black
Blk/Wht
White
Neutral
Line S1
Black (hot)
S2
White
(neutral)
S1
Line
Neutral
8.89” —
16.20” —
4.61”
—
8.89” 1.69”
15.88” 1.69”
17.70”
—
4.57”
—
Blue
DA
Line S1
S2
S2
Blue
Red
Red
Black
L
Blk/Wht
Red
Red
Ballast
Ballast
Ballast
White
Neutral
DA
Violet (control)
Yel
Red
Yel
Red
Red
Blue
Yel
Red
Blue
Yel
Yel
Blue
Yel
Blue
Blue
Ballast
NBlack
White
Blk/Wht
Violet (control)
Blue
DA
Blue
6
Black (hot)
S1
White
Line (neutral)
S2
L
Black
N
Blk/Wht
11
11
11
Red
Red
Ballast
7
Red
DIAGRAM
6
Red
7
Black (hot)
White (neutral)
Red
Red
Ballast
Black (hot)
Fluorescent Dimming
7
L
N
Line S1
Black (hot)S2
L
N
-A, ST, -ZZ
White
Violet (control
+)(neutral)
(+)
Gray (control -)
(-)
Red
Red
Blue
Blue
C11, DP2
Ballast
Violet (control +)
Gray (control -)
WIRING DIAGRAMS
(+)
(-)
Violet (control +)
Gray (control -)
Black (hot)
L
White (neutral)Violet (control)
N (control)
Violet
1
L
N
DA
2
Black (hot) Black (hot)
L
White (neutral)
White (neutral)
N
Red
Red
Blue
Ballast
Violet (control)
Violet (control)
2
DIAGRAM 1
DA
DA
Blue
Blue
Black (hot)
White (neutral)
L
N
2
Violet
(control)
Black
(hot)
L
Violet (control)
White (neutral)
N
Violet (control)
Violet (control)
Red
Red
Yel
Ballast
Black (hot)
DA
Red Blue
White
DA
Blue
Violet (control
+)(neutral)
Red
(+)
Gray (control -)
(-)
Yel
Ballast Yel
L
N
3
DIAGRAM 2
Violet (control +)
DA
Blue
Black (hot)Gray
L (control -)
DA White (neutral) Blue
N
Black (hot)
L
White (neutral)Violet (control)
N (control)
Violet
(+)
(-)
Red
Red
Ballast
Blue
Red
DA
Yel
Yel
Blue
Red
Red
Blue
Yel
Ballast
Red
DA
Violet (control)
Blue
Blue
DA
Red
Red
Ballast
Yel
Yel
Violet
(control)
Black
(hot)
L
Violet (control)
White (neutral)
N
4
Red
Red
5
L
Yel
Red
Blue
Blue
N
Blue
Blue
Black (hot)Gray (control -)
L
White (neutral)
N
4
Red
Red
Red
DA
DIAGRAM
4
DA
Violet (control)
6
DA
DA
Black (hot)
White (neutral)
Blue
Blue
L
N
6
Ballast
Blue
Bla
Blk/W
Wh
Neutral
Line S1
S2
Bla
Blk/W
Wh
Neutral
815
DIAGRAM
14
Red
L
N
Red
Yel
Yel
15
Red
BlueRed
Red/Wht
BlueRed
Yel
Ballast
Ballast Yel
Red
Yel
Red/Wht
Blue
Blue Blue
Line
Black
Neutral
White
16
16
16
Red
L
DIAGRAM
15
Blue
N
Yel
Ballast
Blue
Red
Red/Wht
Yel
Red
7
Line
Bla
Neutral
Wh
Line
Bla
Wh
Neutral
Violet (control
Ballast
Gray (contro
Violet (contro
Gray (contro
BallastYel/Blk
Blue
Yel
Blue/Wht
BallastRed/Wht
Blue
(+)
Gray
(control
Black
(hot)-)
Violet (control +) L (-)
White (neutral) (+)
Gray (control -) N
(-)
Yel
Blue
Yel/Blk
Red/Wht
Red
Blue/Wht
Yel/Blk
Red
Blue/Wht
Black
17
7
10
17
White (neu
Ballast
DA
DA
17
17
17
Yel
White
Neutral
Violet (control
+)
Gray (control -)
Violet (control -)
Gray (control -)
Violet (control +)
Gray (control -)
Black (hot)
Black
(hot)
White
(neutral)
White (neutral)
Violet (control +)
Violet
Gray(control
(control+)
-)
Gray (control -)
Blue
Blue
Yel
Yel
L
N
Black (hot)
Violet (control
L
Red+)
White (neutral)Violet (control) DA
Gray (control
N (control)
Red-)
Violet
DA
Yel
Ballast Yel
DA
DA
8
(-)
18
L
LN
N
Ballast
Ballast
(+)
(+)
(-)
(-)
9
Red
Red
Red
Red
Yel
Yel
Yel
Line
19
12
9
Red
Red
Red
Red
Red
Red
Yel
Ballast
Yel Blue
Blue
Blue
Blue
Yel
Yel
Blue
Blue
Neutral
L
N
W
Vio
Gr
Red
W
Vio
20
1410
Gr
Blue
Red
Red
Red
L1
Ballast
L2 Black (hot) L Red
White White (neutral)
DA
Violet (control)
N
N Yel
DA
Violet (control) Ballast
Yel
Blk/Wht
20
Violet
(control -)
Black
(hot)
L
Gray (control -)
White (neutral)
N
Blue
Blue
(+)
Yel
Yel
Blue
Blue
Ballast
Red
Red
(-)
DIAGRAM
20
Ballast
Violet (control)
DA
Violet (control)
DA
Red
Red
Yel
Yel
Blue
Blue
Yel
Yel
Blue
Blue
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Red
W
Red
Ballast
Black
B
Blk
Yel
Blue
Blue
Blue
Blue
N
(-)
S1
S2
Neutral
Yel
Yel
Red
Blue
Red
Red
Blue
Yel
Yel
Ballast
Ballast Yel Yel
Black (hot)
L
BlueRed
White (neutral)
Blue
N
BlueRed
Blue
Yel
Ballast Yel
Black (hot)
W
Yel
Blue
Blue
Blue
Blue
L
DIAGRAM
18Red
White (neutral)
20
L
Ballast
Violet (contr
Line Gray
S1 (contB
Blk
S2
Neutral
DIAGRAM
17
(-)
(+)
Black (hot)
Line S1
S2
PAGE 2-22
Black (hot)
Blue
Blue
Red
Yel
Blue
Blue
Red
Red
Blue
Red
Yel
Ballast Yel
Yel
(+)
DIAGRAM
19Blue
Blue
Blue
Yel
Black
White (neu
Ballast
(+)
Gray (control -)
Ballast
(+)
(-)
Red
Red
Red
Red
Red
Yel
Red/Wht
Yel
Ballast
Ballast Yel
Blue
Violet (control +)
13
6 9
Gray (cont
10
18
Ballast
White (neutral)
Blue Blue
Blue Blue
Violet (contr
Red/Wht
Black
Line S1
Black
Line S1
Violet
(control +)L
Blk/Wht
(+)
S2
S2
Blk/Wht
Gray (control -)N
Neutral
White
(-)
White
Neutral
Red Red
Red Red
Yel
L
N
LL
NN
L
(+)
N
(-)
Violet
Violet(control
(control
+) (+)
Black -)(hot)
(+)
L
Violet
(control
Gray
(control
-) +)
Gray
(control
-) (+)
White
(neutral)
Black
(hot) (-)(-)
N
Gray (control -) L
White (neutral) (-)
N
Yel
Yel
Violet (controlBlue
+)
(+)
Blue
Gray (control
-)
(-)
6
Violet (control)
Yel
Red
Red
Ballast
Ballast
Yel
Yel
Black
Line S1
S2
Blk/Wht
Black (hot)
White
NeutralBlack (hot)White
L (neutral)
White (neutral)
N
Violet (control)
Red
Red
Black
(hot)
Black
(hot)
Black
LineWhite
White(neutral)
(neutral)
18 11
Blue
Blue
White
Neutral
Red
Ballast
(+)
Blue
DIAGRAM
16
(-)
Blue
Red
Violet (control +)
-)
Black
Line Gray (control
Red 10
DIAGRAM
Ballast
Blue
Blue
Ballast
Violet (control)
(+)
(-)
Black (hot)
Red
Black (hot)
Black
Line LS1
L
White (neutral)Violet (control) DA
NS2(control)
Red
Blk/Wht
White
(neutral)
Violet
N
DA
White
Neutral
Yel
Ballast
Black (hot)
L
White (neutral)Violet (control)
N (control)
Violet
Yel
9
Ballast
Blue
Blue
Yel
Ballast
Black (hot)
Violet (control)
WhiteDA
(neutral)
Violet (control)
DA
8
Ballast
Violet (control +)
DIAGRAM 11
5
DA
DA
White
Black
Line
L
White
Neutral
N
Black
LineViolet (control
+) L
(+)
White
Neutral
Gray (control
-) N
(-)
Red
Red/Wht
Yel
Red
Red
RedRed/Wht
BlueBallast
Blue
Blue
Yel
Yel
Red
Red
Violet (control -)
Violet (control)
L
DIAGRAM
3
N
Black (hot)
L
N
Yel
Blue
White (neutral)
Blk/Wht
Line S1
S2
Yel
Red
Yel
Red
Red
Blue
Yel
Red
Blue
Yel
Yel
Blue
Yel
Blue
Blue
Blue
Yel
4
Violet (control)
4
DA
Ballast
L1
L2
L1
N
L2
N
Black
Line S1
S2
Blk/Wht
Violet
(control +) White
Neutral
(+)
Gray (control -)
(-)
Yel
Yel
Black (hot)
L
Red
Violet (control
+)(hot)
White (neutral)Violet (control)
BlueRed
DABlack
N (control)
Red-) (+) L Blue
Gray
(control
Violet
Black
Line
White
(-) N Blue
BlueRedRed
DA (neutral)
Neutral Yel White
L
Red/Wht
Ballast Yel
Yel
N Ballast
Black
Line
Violet (control)
BallastYel Red
DA
Blue
Neutral
Violet
(control +)White L
Violet (control)
Red/Wht
(+)
Blue
DA
Blue Black
Yel
Line
Red
Violet
(control
Gray
(control
-) +) (+)
(-) N
Blue
White
Neutral
Gray (control
-) L
Red/Wht
(-)
Ballast
Blue
N
Black (hot)
RedYel
Violet (control +)L
(+) Ballast
White(hot)
(neutral)
Black
L -)N
Red Red
Gray (control
Yel
(-)
WhiteViolet
(neutral)
Blue
(control
N +) (+)
Red
Gray (control -)
(-) Ballast
Yel Blue
Ballast
Black +)
(hot)
Yel
Violet (control
Red
(+)L
Blue
White
Violet Gray
(control
-)(neutral)
(control
-)
Red
(+) (-) N
Blue Blue
Gray (control -)
(-)
Blue
Yel
Ballast Yel
Ballast
Violet (control)
Black
Blk/Wht
Black
White
Black (hot)
Yel
7
10
10
9
Red
Black (hot) Red
L
Yel
N
3
L2
N
White
S1
Black
Line
Violet
(control
Black+)(hot)(+)
L
S2 -) Blk/Wht
GrayWhite
(control
(neutral)(-)
N
White
Neutral
DIAGRAM 9
9
White (neutral)
Ballast
B
Neutral
Blue
Red
Blue
Red
L1
Blk/Wht
White (neutral)
Yel
Blue
Ballast
Blue
DA
Black
Ballast
Red/Wht
(-)
14
14
14
DIAGRAM 12
Blue
White
Neutral
29
Ballast
Red
Red
Black
Line S1
S2
S1
Line
Neutral
S2
DIAGRAM 8
1
Black (hot)
Yel
Red
RedYel
Red
RedRed
Blue
Yel
Red
BallastYelBlue
Ballast Yel Yel
Yel
Ballast RedBlue
Yel
Blue
Red
Blue
Blue
Blue
Ballast
Blue
Red
Red
Blue
Blk/Wht
Neutral
15
DIAGRAM 78 15
15
Blue
Line S1
S2
Ballast
Ballast
Red
(+)
B
Neutral
Blue
Red
Red
Black
Blk/Wht
White
Line S1
S2
Blue
Ballast
Blue
Yel
Yel
Line S1
S2
Ballast
Ballast case must be grounded. A star washer
or other paint penetrating device is required
White (neutral)
12
6
12
12
13
13
White
Neutral
Ballast
Ballast
Yel
Blue
Blue
Blk/Wht
Line S1
S2
Blue
Blue
Red
Red
Yel
Yel
Red
Red
Blue
Ballast
White
Neutral
Black
Line S1
Violet (control)
S2
Blk/Wht DA
White DA
Neutral Violet (control)
8
(+)
(-)
White
Neutral
White (neutral)
Black
Line S1
S2
Blk/Wht
S1 (hot) Ballast
Black
Black
Line
White
Neutral
L
White
(neutral)Blk/Wht
Violet (control
+)S2
N
(+)
White
Neutral
Gray (control
-)
(-)
Black
Ballast
Black
L
N
Line S1
S2
Black
Line S1
Black (hot)
L
S2
Blk/Wht
White
S1 (neutral)
Black
Line
N
White
Neutral
S2
Blk/Wht
Blue
Blue
BlueRed
BlueRed
Blk/Wht
White
Neutral
Ballast
Gray (control -)
Blk/Wht
Blue
Violet (control
Black+)(hot)(+)
L
GrayWhite
(control
-)
(neutral)
(-) N
Violet (control +)
11
Blue
Red
Red
Ballast
-D, DP1
Blue
Red
Red
Neutral
Line S1
S2
13
13
13
7
L
N
DA
Ballast
Yel
White
Neutral
Ballast Yel
Black
Line S1
Ballast Red
Violet (control)
S2
Blk/Wht
DA
Blue
Red
S1
Black
Line
Violet
(control)
White
Neutral
Red
DA
Blue
Blue
S2
Blk/Wht
Red
Ballast Blue
White
Neutral
Black (hot)
White (neutral)
Blue
Black
Neutral
Blue
DIAGRAM 5
Note: Nominal dimensions provided above
Contact Universal for drawings
and/or tolerances
Ballast
Violet (control)
DA
Violet (control)
Mounting Dimensions
H
M
X
W
Yel
Yel
Ballast
Ballast
Violet (control)
Violet (control)
DA
4
DIMENSIONS
AND WIRING DIAGRAMS
11
3
Black (hot)
Yel
Yel
Ballast
Ballast
Violet (control)
VariPRO
VariPRO DIMMING BALLASTS
0-10V
DIMMING
T8
PARALLEL LAMP
1
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor Ballast
THD
(PF)
Factor (BF)
%
Min. F/C
Start Wiring
Temp1 Diag. Dim.
0.15 17
0.07 17 0.90 0.87
< 19
32/0
18
-A
0.06 17
0.27 32
0.11 31 0.96 0.87
< 12
32/0
8
-A
0.09
31
0.15 24
0.09 23 0.94 0.87
< 15
32/0
18
-A
0.07 23
0.36 45
0.15 44 0.98 0.87
< 10
32/0
8
-A
0.12
44
0.26 31
0.11 30 0.96 0.88
< 12
32/0
18
-A
0.09 30
0.48 57
0.21 57 0.98 0.87
< 10
32/0
8
-A
0.16
57
0.31 38
0.13 37 0.97 0.87
< 10
32/0
18
-A
0.11 37
0.59 71
0.25 70 0.99 0.87
< 10
32/0
8
-A
0.20
70
0.25 30
0.11 29 0.95 0.87
< 12
60/15
18
-A
0.09 29
0.46 55
0.19 54 0.98 0.87
< 10
60/15
8
-A
0.16
54
0.22 26
0.09 26 0.94 0.87
< 14
60/15
18
-A
0.09 26
0.40 49
0.17 48 0.98 0.87
< 10
60/15
8
-A
0.14
48
0.20 24
0.09 23 0.94 0.87
< 15
60/15
18
-A
0.07 23
0.37 45
0.16 44 0.98 0.87
< 10
60/15
8
-A
0.13
44
A short stabilization period may be needed for temperatures below 10C
See page 2-22 for Dimensions
and Wiring Diagrams
PAGE 2-23
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent Dimming
Lamp
Starting Line
Catalog
Qty. Method
Volts
Number
F17T8
120
B232PUSV3PLA
1 PRS 277
B232PUSV3PLA
347
B232P3SV3PLA
120
B232PUSV3PLA
2 PRS 277
B232PUSV3PLA
347
B232P3SV3PLA
F25T8
120
B232PUSV3PLA
B232PUSV3PLA
1 PRS 277
347
B232P3SV3PLA
120
B232PUSV3PLA
2 PRS 277
B232PUSV3PLA
347
B232P3SV3PLA
F32T8
120
B232PUSV3PLA
1 PRS 277
B232PUSV3PLA
347
B232P3SV3PLA
120
B232PUSV3PLA
2 PRS 277
B232PUSV3PLA
347
B232P3SV3PLA
F40T8
120
B232PUSV3PLA
B232PUSV3PLA
1 PRS 277
347
B232P3SV3PLA
B232PUSV3PLA
120
2 PRS 277
B232PUSV3PLA
347
B232P3SV3PLA
F32T8 (30W)
120
B232PUSV3PLA
B232PUSV3PLA
1 PRS 277
347
B232P3SV3PLA
120
B232PUSV3PLA
2 PRS 277
B232PUSV3PLA
347
B232P3SV3PLA
F28T8
120
B232PUSV3PLA
1 PRS 277
B232PUSV3PLA
347
B232P3SV3PLA
120
B232PUSV3PLA
2 PRS 277
B232PUSV3PLA
347
B232P3SV3PLA
F30T8 (25W)
120
B232PUSV3PLA
1 PRS 277
B232PUSV3PLA
347
B232P3SV3PLA
120
B232PUSV3PLA
2 PRS 277
B232PUSV3PLA
347
B232P3SV3PLA
VariPRO
VariPRO DIMMING BALLASTS
Fluorescent Dimming
0-10V
DIMMING
T5
Lamp
Starting Line
Catalog
Qty. Method
Volts
Number
F14T5
120
B228PUSV3PLA
1 PRS 277
B228PUSV3PLA
347
B228P3SV3PLA
120
B228PUSV3PLA
2 PRS 277
B228PUSV3PLA
347
B228P3SV3PLA
F21T5
120
B228PUSV3PLA
B228PUSV3PLA
1 PRS 277
347
B228P3SV3PLA
120
B228PUSV3PLA
2 PRS 277
B228PUSV3PLA
347
B228P3SV3PLA
F28T5
120
B228PUSV3PLA
1 PRS 277
B228PUSV3PLA
347
B228P3SV3PLA
120
B228PUSV3PLA
2 PRS 277
B228PUSV3PLA
347
B228P3SV3PLA
F28T5ES (25W)
120
B228PUSV3PLA
B228PUSV3PLA
1 PRS 277
347
B228P3SV3PLA
B228PUSV3PLA
120
2 PRS 277
B228PUSV3PLA
347
B228P3SV3PLA
1
PARALLEL LAMP
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor Ballast
THD
(PF)
Factor (BF)
%
Min. F/C
Start Wiring
Temp1 Diag. Dim.
0.17 19
0.07 18 0.93 1.00
< 17
50/10
18
-A
0.06 19
0.30 34
0.13 33 0.97 1.00
< 10
50/10
8
-A
0.11
34
0.23 26
0.10 25 0.95 1.00
< 13
50/10
18
-A
0.09 26
0.42 48
0.18 47 0.98 1.00
< 10
50/10
8
-A
0.15
47
0.29 33
0.13 33 0.97 1.00
< 10
50/10
18
-A
0.11 34
0.56 64
0.24 63 0.99 1.00
< 10
50/10
8
-A
0.19
63
0.27 31
0.12 31 0.96 1.00
< 12
60/15
18
-A
0.09 30
0.51 59
0.22 57 0.99 1.00
< 10
60/15
8
-A
0.17
58
A short stabilization period may be needed for temperatures below 10C
See page 2-22 for Dimensions
and Wiring Diagrams
PAGE 2-24
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
VariPRO
VariPRO DIMMING BALLASTS
0-10V
DIMMING
T5HO
PARALLEL LAMP
1
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor Ballast
THD
(PF)
Factor (BF)
%
Min. F/C
Start Wiring
Temp1 Diag. Dim.
0.46 54
0.21 56 0.97 1.00
< 10
32/0
18
-D
0.18 58
0.98 116
0.42 112 0.99 1.00
< 10
32/0
8
-D
0.33
109
0.44 52
0.20 53 0.96 1.00
< 10
60/15
18
-D
0.16 54
0.86 102
0.38 101 0.99 1.00
< 10
60/15
8
-D
0.30
101
0.47 58
0.21 58 0.97 0.90
< 10
60/15
18
-D
0.17 57
0.89 109
0.38 105 0.99 0.90
< 10
60/15
8
-D
0.31
108
0.45 54
0.19 53 0.96 0.90
< 10
60/15
18
-D
0.16 56
0.86 105
0.37 103 0.98 0.90
< 10
60/15
8
-D
0.30
105
A short stabilization period may be needed for temperatures below 10C
See page 2-22 for Dimensions
and Wiring Diagrams
PAGE 2-25
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent Dimming
Lamp
Starting Line
Catalog
Qty. Method
Volts
Number
F54T5HO
120
B254PUSV3PLD
1 PRS 277
B254PUSV3PLD
347
B254P3SV3PLD
120
B254PUSV3PLD
2 PRS 277
B254PUSV3PLD
347
B254P3SV3PLD
F54T5HOES (49W)
120
B254PUSV3PLD
B254PUSV3PLD
1 PRS 277
347
B254P3SV3PLD
120
B254PUSV3PLD
2 PRS 277
B254PUSV3PLD
347
B254P3SV3PLD
FT55W/2G11
120
B254PUSV3PLD
1 PRS 277
B254PUSV3PLD
347
B254P3SV3PLD
120
B254PUSV3PLD
2 PRS 277
B254PUSV3PLD
347
B254P3SV3PLD
FC55T5HO
120
B254PUSV3PLD
B254PUSV3PLD
1 PRS 277
347
B254P3SV3PLD
B254PUSV3PLD
120
2 PRS 277
B254PUSV3PLD
347
B254P3SV3PLD
LevelPRO
LevelPRO DIMMING BALLASTS
Fluorescent Dimming
STEP-DIMMING
HIGH BALLAST
FACTOR
Lamp
Starting Line
Catalog
Qty. Method
Volts
Number
F17T8
120
B232PUS50PLHA
1 PRS 277
B232PUS50PLHA
347
B232P3S50PLHA
120
B232PUS50PLHA
2 PRS 277
B232PUS50PLHA
347
B232P3S50PLHA
F25T8
120
B232PUS50PLHA
B232PUS50PLHA
1 PRS 277
347
B232P3S50PLHA
120
B232PUS50PLHA
2 PRS 277
B232PUS50PLHA
347
B232P3S50PLHA
F32T8
120
B232PUS50PLHA
1 PRS 277
B232PUS50PLHA
347
B232P3S50PLHA
120
B232PUS50PLHA
2 PRS 277
B232PUS50PLHA
347
B232P3S50PLHA
F32T8 (30W)
120
B232PUS50PLHA
B232PUS50PLHA
1 PRS 277
347
B232P3S50PLHA
B232PUS50PLHA
120
2 PRS 277
B232PUS50PLHA
347
B232P3S50PLHA
F28T8
120
B232PUS50PLHA
B232PUS50PLHA
1 PRS 277
347
B232P3S50PLHA
120
B232PUS50PLHA
2 PRS 277
B232PUS50PLHA
347
B232P3S50PLHA
F30T8 (25W)
120
B232PUS50PLHA
1 PRS 277
B232PUS50PLHA
347
B232P3S50PLHA
120
B232PUS50PLHA
2 PRS 277
B232PUS50PLHA
347
B232P3S50PLHA
1
PARALLEL LAMP
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor Ballast
THD
(PF)
Factor (BF)
%
Min. F/C
Start Wiring
Temp1 Diag. Dim.
0.19 23
0.08 23 0.96 1.15
< 15
32/0
19
-A
0.07 22
0.35 42
0.15 41 0.98 1.15
< 10
32/0
12
-A
0.12
41
0.27 32
0.12 32 0.97 1.15
< 10
32/0
19
-A
0.09 31
0.50 60
0.21 59 0.99 1.15
< 10
32/0
12
-A
0.17
59
0.34 40
0.15 40 0.98 1.15
< 10
32/0
19
-A
0.12 39
0.64 77
0.27 75 0.99 1.15
< 10
32/0
12
-A
0.22
75
0.32 38
0.14 38
0.98 1.15 < 10
60/15
19
-A
0.11 38
0.60 72
0.25 70 0.99 1.15
< 10
60/15
12
-A
0.20
69
0.28 34
0.12 33 0.98 1.15
< 10
60/15
19
-A
0.10 33
0.54 65
0.23 63 0.99 1.15
< 10
60/15
12
-A
0.18
63
0.27 32
0.12 32 0.97 1.15
< 10
60/15
19
-A
0.09 31
0.50 60
0.21 59 0.99 1.15
< 10
60/15
12
-A
0.17
59
A short stabilization period may be needed for temperatures below 10C
See page 2-22 for Dimensions
and Wiring Diagrams
PAGE 2-26
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
LevelPRO
LevelPRO DIMMING BALLASTS
STEP-DIMMING
NORMAL BALLAST
FACTOR
LIGHT-LEVEL SWITCHING
PARALLEL LAMP
1
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor Ballast
THD
(PF)
Factor (BF)
%
Min. F/C
Start Wiring
Temp1 Diag. Dim.
0.15 17
0.06 17 0.94 0.87
< 19
32/0
19
-A
0.05 17
0.26 31
0.11 31 0.97 0.87
< 10
32/0
12
-A
0.09
31
0.21 25
0.09 25 0.96 0.87
< 14
32/0
19
-A
0.07 25
0.38 46
0.16 44 0.98 0.87
< 10
32/0
12
-A
0.13
44
0.26 31
0.11 31 0.97 0.88
< 11
32/0
19
-A
0.09 31
0.48 59
0.21 58 0.99 0.87
< 10
32/0
12
-A
0.17
58
0.32 39
0.14 38 0.98 0.87
< 10
32/0
19
-A
0.11 38
0.61 74
0.26 72 0.99 0.87
< 10
32/0
12
-A
0.21
72
0.24 29
0.10 29 0.97 0.87
< 12
60/15
19
-A
0.08 29
0.46 56
0.19 54 0.99 0.87
< 10
60/15
12
-A
0.16
54
0.22 26
0.09 26 0.96 0.87
< 14
60/15
19
-A
0.08 25
0.41 49
0.17 48 0.99 0.87
< 10
60/15
12
-A
0.14
48
A short stabilization period may be needed for temperatures below 10C
See page 2-22 for Dimensions
and Wiring Diagrams
See page 2-20 for Dimensions
and Wiring Diagrams
PAGE 2-27
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Fluorescent Dimming
Lamp
Starting Line
Catalog
Qty. Method
Volts
Number
F17T8
120
B232PUS50PLA
1 PRS 277
B232PUS50PLA
347
B232P3S50PLA
120
B232PUS50PLA
2 PRS 277
B232PUS50PLA
347
B232P3S50PLA
F25T8
120
B232PUS50PLA
B232PUS50PLA
1 PRS 277
347
B232P3S50PLA
120
B232PUS50PLA
2 PRS 277
B232PUS50PLA
347
B232P3S50PLA
F32T8
120
B232PUS50PLA
1 PRS 277
B232PUS50PLA
347
B232P3S50PLA
120
B232PUS50PLA
2 PRS 277
B232PUS50PLA
347
B232P3S50PLA
F40T8
120
B232PUS50PLA
B232PUS50PLA
1 PRS 277
347
B232P3S50PLA
B232PUS50PLA
120
2 PRS 277
B232PUS50PLA
347
B232P3S50PLA
F32T8 (30W)
120
B232PUS50PLA
B232PUS50PLA
1 PRS 277
347
B232P3S50PLA
120
B232PUS50PLA
2 PRS 277
B232PUS50PLA
347
B232P3S50PLA
F28T8
120
B232PUS50PLA
1 PRS 277
B232PUS50PLA
347
B232P3S50PLA
120
B232PUS50PLA
2 PRS 277
B232PUS50PLA
347
B232P3S50PLA
LevelPRO
LevelPRO DIMMING BALLASTS
Fluorescent Dimming
STEP-DIMMING
NORMAL BALLAST
FACTOR
Lamp
Starting Line
Catalog
Qty. Method
Volts
Number
F30T8 (25W)
120
B232PUS50PLA
1 PRS 277
B232PUS50PLA
347
B232P3S50PLA
120
B232PUS50PLA
2 PRS 277
B232PUS50PLA
347
B232P3S50PLA
F14T5
120
B232PUS50PLA
B232PUS50PLA
1 PRS 277
347
B232P3S50PLA
120
B232PUS50PLA
2 PRS 277
B232PUS50PLA
347
B232P3S50PLA
F21T5
120
B232PUS50PLA
1 PRS 277
B232PUS50PLA
347
B232P3S50PLA
120
B232PUS50PLA
2 PRS 277
B232PUS50PLA
347
B232P3S50PLA
F28T5
120
B232PUS50PLA
B232PUS50PLA
1 PRS 277
347
B232P3S50PLA
B232PUS50PLA
120
2 PRS 277
B232PUS50PLA
347
B232P3S50PLA
F28T5ES (25W)
120
B232PUS50PLA
B232PUS50PLA
1 PRS 277
347
B232P3S50PLA
120
B232PUS50PLA
2 PRS 277
B232PUS50PLA
347
B232P3S50PLA
1
LIGHT-LEVEL SWITCHING
PARALLEL LAMP
Line
Current
(Amps)
Input
Power
(Watts)
Power
Factor Ballast
THD
(PF)
Factor (BF)
%
Min. F/C
Start Wiring
Temp1 Diag. Dim.
0.21 25
0.09 25 0.96 0.87
< 14
60/15
19
-A
0.07 25
0.38 46
0.16 44 0.98 0.87
< 10
60/15
12
-A
0.13
44
0.16 19
0.07 19 0.94 1.00
< 17
50/10
19
-A
0.06 19
0.30 34
0.13 34 0.98 1.00
< 10
50/10
12
-A
0.10
34
0.23 26
0.10 26 0.96 1.00
< 12
50/10
19
-A
0.08 26
0.42 49
0.18 48 0.99 1.00
< 10
50/10
12
-A
0.14
48
0.29 34
0.12 33 0.97 1.00
< 10
50/10
19
-A
0.10 33
0.56 65
0.24 63 0.99 1.00
< 10
50/10
12
-A
0.19
63
0.26 30
0.11 30 0.97 1.00
< 12
60/15
19
-A
0.09 29
0.51 59
0.25 58 0.97 1.00
< 10
60/15
12
-A
0.17
58
A short stabilization period may be neede
See page 2-22 for Dimensions
and Wiring Diagrams
PAGE 2-28
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Notes
Fluorescent Dimming
PAGE 2-29
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Compact Fluorescent
Ballasts
The Courage To Dream Small
Universal Lighting Technologies (“Universal”) offers a full
range of electronic programmed start compact fluorescent
ballasts to address most commercial applications.
Our electronic models offer high efficiency for maximum
energy savings and installer-friendly universal input
voltage, which reduces your inventory and ensures that
you have the right voltage ballast every time. A complete
range of 347 volt models are also available that offer
outstanding reliability and lamp performance. These models
feature a low profile case that fits in any fixture. And their
metal housing construction meets all plenum codes and
delivers maximum heat transfer to extend ballast life.
Compact Fluorescent
Our compact fluorescent models offer installer-friendly universal input voltage.
Universal Lighting Technologies is a member of the Panasonic Group
Product Overview
Triad® Electronic CFL Ballasts:
• High efficiency for maximum energy savings.
• Universal input voltage of 120-277V. Installer friendly universal input voltage, which reduces inventory and ensures that
you have the right voltage ballast every time.
• Complete range of 347 volt CFL models that offer outstanding reliability and lamp performance.
• Programmed Rapid Startiting (PRS) incorporated. PRS is recommended by all lamp manufacturers. Increases lamp life for
those frequently switched applications where occupancy sensors are used. Meets all requirements of rapid start specs
and more.
• Metal can construction. Metal housing construction meets all plenum codes and construction code requirements.
It also delivers maximum heat transfer to extend ballast life. Designed and manufactured for long life.
• Meets all applicable regulatory and safety standards. ANSI C82.11 Ballast Specification, UL 935, FCC Part 18 (Class A),
and UL2043 suitable for Air Handling spaces.
• 1- or 2- lamp operation of multiple lamp applications. Multiple lamp options on each ballast for added versatility in
applications.
• THD<10%
• Type CC and Type HL (hazardous locations) rated. Type CC is an anti-arcing feature that is used to reduce arcing caused
by loose connections or improper lamp-pin to lampholder contact. The Type CC feature senses this arcing and shuts
down the ballastt to prevent damage.
• Dual entry color coded wire trap terminals. For wiring accuracy and ease of installation.
• Low profile form case fits in any fixture. Use for surface or junction box mounting. Small size means less wasted space
than full alternative.
• End of lamp life shutdown circuit. Meets ANSI/NEMA requirements. Allows you to replace failed lamps without turning off
power.
• 75° C Temperature Test point. Maximum Case Temperature of 75° C allows for easy ballast/fixture testing, assuring
proper temperature application.
• Lamp proximity. Lamps can be mounted in close proximity to these ballasts due to no temperature critical components
near the can sides. And, their circuit board potting enhances reliability by lowering case temperatures.
• Warranty. Backed by Triad® five year warranty.
Compact Fluorescent
CFL Replacement Kits
The multi-exit ballast lead wire connectors accommodate side and bottom lead exit requirements. The snap mount adapter
plate adds bottom-exit studs and additional flexibility for replacement of older magnetic ballasts. They also fit virtually every
j-box cover and fixture application. This product is for distribution sale only.
Mult-E Kit products:
C213UNVME000K
C218UNVME000K
C2642UNVME000K
C213/347ME001K
C218/347ME001K
C2642/347ME001K
Mult-E Kit contains:
• Multi-exit ballast for use in both side-exit and bottom-exit replacement applications.
• Snap-mount adapter plate speeds up installation time. No hardware required for attaching snap-mount adapter plate.
• Lead wire set
• Wire extraction tool
• Instructions
FOR MORE INFORMATION CALL
PAGE 3-2
1-800-BALLAST
(225-5278)
Understanding Compact Fluorescent Technology
Compact fluorescent (CFL) lamps are single-ended and
plug into sockets. They’re sometimes referred to as
“single-based” or “single-ended” fluorescent lamps.
Lamp Shapes
Today’s CFL lamps come in these basic shapes: twin tube,
quad, triple, multi, square and circular. Each of these
shapes has its own subset of sizes. For example, the twin
tube may range from 4˝ long (5 watt) to 22˝ long (40 watt).
OR
OR
Long Twin T5, 4-Pin
5w – 80w
Twin, 2-Pin
5w – 13w
OR
2-Pin
4-Pin
Quad 9w – 27w
Square (2D)
10w – 55w
Lamp Bases
There are a variety of lamp bases used with today’s CFL
lamps. This provides a safeguard to make sure that the
proper lamp/ballast combination is installed. The lamp
base style is part of the ANSI/NEMA
designation.
In this catalog, Universal CFL ballasts are classified
according to lamp type. Icons representing each lamp
type provide a quick visual reference. Within each
classification, the lamps and their appropriate ballasts
can be found by referring to the generic NEMA lamp
descriptions.
Lamp Designation
There are two different industry-recognized
nomenclatures for identifying CFL lamps: ANSI
Lamp Designations and NEMA Lamp Designations.
Here are examples of each:
ANSI Designation
13W / 7T4 / T / GX23 / PH
Lamp
Wattage
Multiple, 4-Pin
(GE & OSI)
18w – 70w
Multiple, 4-Pin
(Philips)
18w – 42w
T5 Circular
22w - 55w
Lamp
Diameter
1/8˝
Base
Starting:
PH – Preheat
RS – Rapid Start
CFT 13W / GX23
Twin (T)
Quad (Q)
Multi (M)
2D (S)
Lamp
Wattage
Base
Both lamp designations refer to lamp wattage, shape,
and base type. Since the NEMA designation is shorter, it
will probably be the nomenclature of choice in the future.
All of the major lamp companies have trade names for
various CFL lamp types, such as GE’s “Biax” and “2D”
lamps, OSI’s “Dulux,” and Philips’ “PL”. These names
have become more widely used than either of the industry designations.
GE
OSI Philips
Low Watt Biax
Dulux S, S/E
PL-S
Double Biax
Dulux D, D/E PL-C
Biax T/E
Dulux T, T/E, T/E/IN PL-T
Biax Q/E
Dulux T/E/IN
PL-T
High Lumen Biax
Dulux L, F
PL-L
2D
––
––
—
Pentron
Silhouette
FOR MORE INFORMATION CALL
PAGE 3-3
1-800-BALLAST
(225-5278)
Compact Fluorescent
Industry
Watts
Single or Twin
5, 7, 9, 13
Double or Quad
9, 13, 18, 20, 26, 27
Multiple
13, 18, 26, 32, 42
Multiple
42, 57, 70
Long Twin T5
18, 24/27, 36/39, 40, 50, 80
Square
10, 16, 21, 28, 38, 55
Circline
22, 40, 55
Twin (T)
Quad (Q)
Multi (M)
2D (S)
NEMA Designation
Pins and Starters
CFL lamps feature either two pins or four pins.
Four-pin lamps are traditionally powered by electronic
ballasts. These lamps do not have an internal starter, so
the other filament terminals (pins) are made
accessible for external connection to the ballasts.
Lamp
Length
Configurations
Electronic Bottom Exit (BE)
Electronic Multi-Exit with Studs (MES)
Compact Fluorescent
Electronic Multi-Exit (ME)
FOR MORE INFORMATION CALL
PAGE 3-4
1-800-BALLAST
(225-5278)
Lamp Matrix
ANSI Lamp
Designation
NEMA Lamp
Built-In
LAMP MANUFACTURER
Designation Starter GE
OSI
Philips
5W/4T4/T/G23/PH
CFT5W/G23
7W/5T4/T/G23/PH
CFT7W/G23
9W/6T4/T/G23/PH
CFT9W/G23
13W/7T4/T/GX23/PH CFT13W/GX23
YES
YES
YES
YES
F5 BX
F7 BX
F9 BX
F13 BX
CF 5DS
CF 7DS
CF 9DS
CF 13DS
PL-S 5W
PL-S 7W
PL-S 9W
PL-S 13W
9W/4T4/Q/G23-2/PH
13W/5T4/Q/GX23-2/PH
CFQ9W/G23
CFQ13W/GX23
YES
YES
F9 DBX23
F13 DBX23
CF 9DD
CF 13DD
—
PL-C 13W/USA
13W/6T4/Q/G24d-1/PH
18W/7T4/Q/G24d-2/PH
26W/8T4/Q/G24d-3/PH
CFQ13W/G24d
CFQ18W/G24d
CFQ26W/G24d
YES
YES
YES
F13 DBX T4
F18 DBX T4
F26 DBX T4
—
CF 18DD
CF 26DD
PL-C 13W
PL-C 18W
PL-C 26W
13W/6T4/Q/G24q-1
18W/7T4/Q/G24q-2
26W/8T4/Q/G24q-3
CFQ13W/G24q
CFQ18W/G24q
CFQ26W/G24q
NO
NO
NO
F13 DBX/4P
F18 DBX/4P
F26 DBX/4P
CF 13DD/E
CF 18DD/E
CF 26DD/E
PL-C 13W/4P
PL-C 18W/4P
PL-C 26W/4P
10W/3.5T4/S/GR10q-4
16W/5.5T4/S/GR10q-4
21W/5.5T4/S/GR10q-4
28W/8T6/S/GR8-2/PH
28W/8T6/S/GR10q-4
38W/8T6/S/GR10q-4
55W/8T6/S/GRY10q-3
CFS10W/GR10q
CFS16W/GR10q
CFS21W/GR10q
CFS28W/GR8
CFS28W/GR10q
CFS38W/GR10q
CFS55W/GRY10q
NO
NO
NO
YES
NO
NO
NO
F10 2D/4P
F16 2D/4P
F21 2D/4P
F28 2D
F28 2D/4P
F38 2D/4P
F55 2D/4P
—
—
—
—
—
—
—
—
—
—
—
—
—
—
20W/6T5/Q/GX32d-2/PH
27W/7T5/Q/GX32d-3/PH
CFQ20W/GX32d
CFQ27W/GX32d
YES
YES
—
—
—
—
PL-C 15MM/22W
PL-C 15MM/28W
CFT13W/2GX7
NO
—
Twin, 2-Pin
Quad, 2-Pin
Quad, 2-Pin
OR
Quad, 4-Pin
Square, (2D)
T5 Quad, 2-Pin
13W/6T4/T/2GX7
CF 13DS/E
—
Twin T4, 4-Pin
18-20W/9T5/T/2G11/PH-RS
FT18W/2G11
NO
F18 BX
FT 18DL
—
18W/10T5/T/2G11/RS
FT18W/2G11/RS
NO
F18 BX/RS
FT 18DL/RS
PL-L 18W
18W/5T5/T/2G10
CFM18W/2G10
NO
—
CF 18DF
—
24-27W/13T5/T/2G11/PH-RS FT24W/2G11/RS
NO
F27 BX/RS
FT 24DL
PL-L 24W
24W/7T5/T/2G10
CFM24W/2G10
NO
—
CF 24DF
—
36-39W/16T5/T/2G11/PH-RS FT36W/2G11/RS
NO
F39 BX/RS
FT 36DL
PL-L 36W
36W/9T5/T/2G10 CFM36W/2G10
NO
—
CF 36DF
—
40W/22T5/T/2G11/RS FT40W/2G11/RS
NO
F40 BX/RS
FT 40DL/RS
PL-L 40W/RS
50W/22T5/T/2G11/RS FT50W/2G11/RS
NO
F50 BX/RS
—
PL-L 50W/RS
55W/21T5/T/2G11 FT55W/2G11
NO
F55 BX
FT 55DL
—
80W/22T5/T/2G11 FT80W/2G11 NO —
— PL-L 80W
Long Twin T5, 4-Pin
18W/5T4/M/GX24d-2
CFM18W/GX24d
YES
—
CF 18DT
—
26W/6T4/M/GX24d-3
CFM26W/GX24d
YES
—
CF 26DT
—
13W/5T4/M/GX24q-1
18W/5T4/M/GX24q-2
26W/6T4/M/GX24q-3
32W/6T4/M/GX24q-3
42W/7T4/M/GX24q-4
57W/7T4/M/GX24q-5
70W/8T4/M/GX24q-6
CFM13W/GX24q
CFM18W/GX24q
CFM26W/GX24q
CFM32W/GX24q
CFM42W/GX24q
CFM57W/GX24q
CFM70W/GX24q
NO
NO
NO
NO
NO
NO
NO
F13 TBX/4P
F18 TBX/4P
F26 TBX/4P
F32 TBX/4P/EOL
F42 TBX/4P/EOL
F57 QBX/4P/EOL
F70 QBX/4P/EOL
CF 13DT/E
CF 18DT/E/IN
CF 26DT/E/IN
CF 32DT/E/IN
CF 42DT/E/IN
CF 57DT/E/IN
—
—
PL-T 18W/4P
PL-T 26W/4P
PL-T 32W/4P
PL-T 42W/4P
—
—
FPC22
FPC40
FPC55/HO
FC9T5 22W
FC12T5 40W
FC12T5 55W
Multiple, 4-Pin
—
—
—
FC9T5-22W/2GX13 NO —
FC12T5-40W/2GX13
NO
—
FC12T5-55W/2GX13 NO —
T5 Circular, 4-Pin
FOR MORE INFORMATION CALL
PAGE 3-5
1-800-BALLAST
(225-5278)
Compact Fluorescent
Multiple, 2-Pin
Specifications
TYPICAL SPECIFICATIONS
FOR ELECTRONIC COMPACT FLUORESCENT BALLASTS:
• Ballasts shall be constructed of metal housing to meet plenum and construction code requirements while providing maximum heat transfer
without extra grounding wires for extended ballast life.
• Ballasts shall be constructed using dual entry color coded wire trap terminals for wiring accuracy and ease of installation.
• Ballasts shall be Programmed Start.
• Ballasts shall have a minimum Rh/Rc of 4.25 each time the lamps are started.
• Ballasts shall have a maximum ionization current (Glow Current) of 25 milliamps during preheating interval.
• Ballasts shall operate from 50/60 Hz input source of 120 through 277 Volts, and sustained variations of ± 10% (Voltage &
Frequency) with no damage to the ballasts.
• Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 50 kHz to minimize interference with infrared
control systems.
• Ballasts shall have a minimum starting temperature of 0°F (-18°C) for the primary lamp application.
• Ballasts shall tolerate operation in ambient temperatures up to 140°F (55°C) without damage.
• Ballasts shall have a maximum case temperature test point of 75°C printed on the label for easy fixture testing and trouble shooting.
• Ballasts shall support 12’ lead length remote mounting for the primary lamp.
• Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and RFI (radiated).
• Ballasts shall provide transient immunity as recommended by ANSI C82.11-2011.
• Ballasts shall incorporate end of lamp life shutdown circuitry for end of lamp life protection.
• Ballasts shall allow for re-lamping without the need to cycle power.
• Ballasts shall operate lamps with no visible flicker (<3% flicker index).
• Ballasts shall tolerate sustained open and short circuit output conditions without damage.
• Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor and/or CSA certified for both US and Canadian application.
• Ballasts shall be UL 935 Type CC rated to reduce arcing caused by loose connections or improper lamp-pin to lampholder contact.
• Ballasts shall be UL 2043 certified for use in plenums and marked on label as “Suitable for Air Handling Spaces”.
• Ballasts shall be quiet Class A sound rating.
• Ballasts shall have a Ballast Factor for primary lamp application greater than .95 per ANSI C82.11-2011.
Compact Fluorescent
• Input current Total Harmonic Distortion shall not exceed 10% for the primary lamp.
• Ballasts shall have a Power Factor greater than .98 for the primary lamp application.
• Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp manufacturer recommendation and
ANSI C82.11-2011.
• The ballasts shall not have any PCB’s.
• The manufacturer shall provide written warranty against defects in material or workmanship, including replacement, for five years from
date of manufacture.
• Manufacturer shall have been manufacturing electronic ballasts for at least thirty years.
• Ballasts shall be manufactured in an ISO 9001 / ISO 9002 Certified Facility in North America.
• Ballasts shall be manufactured by Universal Lighting Technologies.
FOR MORE INFORMATION CALL
PAGE 3-6
1-800-BALLAST
(225-5278)
Understanding Universal Part Numbers
ELECTRONIC
Our nomenclature for electronic CFL ballasts follows
the system already in place for other Universal electronic
ballasts. The exceptions are that the model number
prefix for compact fluorescent is a C rather than a B.
Example:Electronic C240PUNVHP-BOOOC
Ballast Type: C — CFL Electronic Ballast
Lamp Qty: 2
Lamp Type: 40W TT5, 4 Pin (FT40W/2611)
P: Programmed Start
Voltage: UNV 120 to 277 volts
HP-B: High Performance <10%; low profile can
000: Color—Black
C: Packaging container style—Carton Pack
Lamp Wattage
UNV or 347V
Color: 001 - White
000 - Black
CXXX XX XXX XXX XXX X
# of SR -Series,
lamps
Rapid Start
P - Programmed Start
BE - Bottom Exit
ME - Multi Exit
MES - Multi Exit with Studs
120V, 277V
347V, UNV
Lamp Wattage* (120-277)
Color: 001 - White
000 - Black
CXXX X XXX XXX XXX
# of
lamps
No suffix - P
P - Programmed
Start
I - Instant Start
C -Carton
T -Tray Pack
I -Individual
K -Replacement Mult-E Kit
X
BE - Bottom Exit
ME -Multi Exit
MES -Multi Exit with Studs
HP-B - Low Profile
RH - Reduced Harmonics
C -Carton
T -Tray Pack
I -Individual
K -Replacement Mult-E Kit
Example: C213UNVMES000C*
Ballast Type: C
Lamp Quantity: 2
Lamp Type: 13W Quad, 4 Pin (CFQ13W/G24q)
Voltage: UNV 120 to 277 volts
MES: Multi-exit connection, with studs
000C: Color—Black
C: Packaging container style—Carton Pack
*Exception is C2642, which does not distinguish number of lamps. See catalog.
Compact Fluorescent
FOR MORE INFORMATION CALL
PAGE 3-7
1-800-BALLAST
(225-5278)
Compact Fluorescent
Notes
FOR MORE INFORMATION CALL
PAGE 3-8
1-800-BALLAST
(225-5278)
MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS FOR TWIN, QUAD
AND MULTIPLE LAMPS
13-26 WATTS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
13 Watts
CFT13W/GX23
OR
CFQ13W/GX23
Lamp Type
13 Watts
CFQ13W/G24q
OR
CFM13W/GX24q
OR
OR
Lamp Type
13 Watts
CFT13W/2GX7
Lamp Type
18 Watts
CFQ18W/G24q
OR
CFM18W/GX24q
Lamp Type
26 Watts
CFQ26W/G24q
OR
CFM26W/GX24q
OR
OR
Twin or
Quad, 2-Pin
U.S. type
• Ideal for downlights & wall sconces
• E lectronic models feature universal input
voltage from 120V to 277V. 347V models are
also available.
• E lectronic models feature programmed start
for excellent lamp performance & auto reset
shutdown circuit
13-26 WATTS
Lead Configuration
Mag Qty
Line Starting Min Start
or of Line Catalog Input Current Current Ballast Temp Power Side Multi Multi Starting Wir
Elec Lamps Volt Number Watts Amps Amps Factor (F/C) Factor THD Exit Exit Exit Studs Method✿ Dim Diag
Electrical Characteristics - 60 Hz
❍ M 1 120 CF1320H2P ■ 16 0.24 0.30 0.85 25°/-4° >.50 <15% X —
—
PH B10 1
■H
2 indicates clamped & covered core & coil with mounting feet.
◆ Add following suffix for complete catalog #: “BE” for Bottom Exit connectors,
“ME” for Multi Exit connectors, or “MES” for Multi Exit with 2” OC screw studs.
❍ Not approved for use in hazardous locations.
rAdd “000K” suffix for Mult-E Kit. For Distribution only.
✱ Add “001K” suffix for Mult-E Kit. For Distribution only.
PAGE 3-9
All ballasts are UL listed, CSA approved and
designated Class P (thermally protected).
See page 3-11 for Dimensions
and Wiring Diagrams.
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Compact Fluorescent
120
0.15
>.98 <10%
E 1
C213UNVMEr 18
—— 1.00 0°/-18°
X X
PS C3 3
277 0.07 >.95 <15%
Quad or
120
0.26
Multiple,
E 2
C213UNVMEr 30
—— 1.00 0°/-18° >.98 <10%
X
X
PS C3 4
4-Pin
277 0.11
1
18
0.06
——
1.00
3
E
347 C213/347ME✱
0°/-18° >.98 <10% X
X
PS C3
2
33
0.10 —— 0.98 4
120
0.12
<10%
E 1
CT213UNVME 15
—— 0.98
0°/-18° >.98
X X
PS C3 3
277 0.06 <12%
Twin T4,
4-Pin
120
0.22
E
2
CT213UNVME 26
—— 0.98 0°/-18° >.98 <10% X
X
PS C3 4
277 0.10
120
0.16
>.98 <10%
E 1
C218UNV ◆r 19
—— 1.00
0°/-18°
X X
PS C3 3
277 0.07 >.95 <15%
Quad or
120
0.30
Multiple, 4-Pin E 2
C218UNV◆r 35
—— 0.95
0°/-18° >.98 <10% X X
PS C3 4
277 0.13
1
21 0.06 —— 1.00
3
E
347 C218/347ME✱
0°/-18° >.98 <10% X X
PS C3
2
38
0.11 —— 0.98 4
120
0.25
E 1
C2642UNV◆r 28
—— 1.02
0°/-18° >.98 <10% X X
PS C3 3
Quad or
277 0.11
Multiple,
120
0.47
4-Pin
E 2
C2642UNV◆r 56
—— 0.98
0°/-18° >.98 <10% X X
PS C3 4
277 0.21
1
31 0.09 —— 1.02
3
E
347 C2642/347ME✱
0°/-18° >.98 <10% X X
PS C3
2
57
0.17 —— 0.98 4
120
56
0.46
E 2
C242UNV◆
—— 1.02
0°/-18° >.95 <10% X X
PS C4 4
277
55 0.20
E 2 347 C242/347ME 44
0.14 —— 1.02 0°/-18º >.98 <10%
X
X
PS C4 4
✿ PH = Preheat; PS = Programmed Start
OR
TWIN, QUAD
& MULTIPLE
LAMPS
• Ideal for downlights, surface mount &
outdoor fixtures
• E lectronic models feature universal input
voltage from 120V to 277V. 347V models
are also available.
• E lectronic models feature programmed
start for excellent lamp performance
& auto reset shutdown circuit
MULTIPLE
LAMPS
32, 42, 57 & 70 WATTS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
32 Watts
CFM32W/GX24q
Multiple, 4-Pin
Lamp Type
42 Watts
CFM42W/GX24q
Multiple, 4-Pin
Lamp Type
57 Watts
CFM57W/GX24q
Multiple, 4-Pin
Compact Fluorescent
Lamp Type
70 Watts
CFM70W/GX24q
ELECTRONIC
COMPACT FLUORESCENT
BALLASTS FOR MULTIPLE LAMPS
32, 42, 57 & 70 WATTS
Lead Configuration
Mag Qty
Line Starting Min Start
or of Line Catalog✪ Input Current Current Ballast Temp Power Side Multi Multi Starting Wir
Elec Lamps Volt
Number
Watts Amps Amps Factor (F/C) Factor THD Exit Exit Exit Studs Method✿ Dim Diag
Electrical Characteristics - 60 Hz
120
0.30
E 1
C2642UNV◆r 36
—— 1.00 0°/-18º >.98 <10% X
X
PS C3 3
277 0.13
✱
E 1 347 C2642/347ME 36 0.11 —— 0.98 0°/-18º >.98 <10% X X
PS C3 3
120
69 0.58
E 2
C242UNV◆
—— 1.00 0°/-18º >.98 <10% X
X
PS C4 4
277
67 0.26
E 2 347 C242/347ME 62 0.19 —— 1.00 0°/-18º >.98 <10% X X
PS C4 4
120
0.41
E 1
C2642UNV ◆r 48
—— 0.98 0°/-18º >.98 <10%
277 0.18
E 1 347 C2642/347ME✱ 50 0.15 —— 1.00 0°/-18º >.98 <10%
120
0.40
E 1
C242UNV◆
45
—— 1.00 0°/-18º >.93 <10%
277
0.18
120
91 0.76
E 2
C242UNV ◆
—— 0.98 0°/-18º >.98 <10%
277
90 0.32
E 1 347 C242/347ME 42 0.13 —— 1.00
0°/-18º >.98 <10%
E 2 347 C242/347ME 80 0.25 —— 0.98
0°/-18º >.98 <10%
120
58 0.52
E 1
C242UNV ◆
—— 1.00 0°/-18º >.98 <10%
277
57 0.21
E 1 347 C242/347ME 61 0.18 —— 1.00 0°/-18º >.98 < 10%
120
73 0.61
>.98
E 1
C242UNV ◆
—— 1.00 0°/-18º
<10%
277
72 0.27
>.95
E 1 347 C242/347ME 74 0.21 —— 1.00 0°/-18º >.98 < 10%
X
X
PS C3 3
X
X
PS C3 3
X
X
PS C4 3
X
X
PS C4 4
X
X
X
X
PS C4 3
PS C4 4
X
X
PS C4 3
X
X
PS
X
X
PS C4 3
X
X
PS
C4 3
C4 3
Multiple, 4-Pin
✿ PS = Programmed Start
◆ Add following suffix for complete catalog #:
“BE”suffix for Bottom Exit connectors, “ME” for
multi-exit connectors, or “MES” for multi exit connectors
with 2” O.C. screw studs.
rAdd “000K” suffix for Mult-E Kit. For Distribution only.
✱ Add “001K” suffix for Mult-E Kit. For Distribution only.
All ballasts are UL listed, CSA approved and
designated Class P (thermally protected), Type HL.
See page 3-11 for Dimensions
and Wiring Diagrams.
FOR MORE INFORMATION CALL
PAGE 3-10
1-800-BALLAST
(225-5278)
TWIN, TRIPLE,
QUAD &
MULTIPLE
LAMPS
MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS
WIRING DIAGRAMS AND DIMENSIONS
REFERENCE DRAWING FOR B10
C
WIRING DIAGRAMS
F
A
Install in accordance with
National Electrical Code.
G
B
D
E
Dwg.
A
B
D
E
B10 1.48” 1.30” 2.68” 3.08”
Black
Leadless-Poke-in wire connection
Black
Line
REFERENCE DRAWING FOR C3
C
Black
BALLAST
White
Green
BALLAST
Red
Red
Blue
Blue
DIAGRAM 3
DIAGRAM 1
Ballast should be grounded
F
A
G
B
D
E
Dwg.
A
B
C
D
E
F
G
Black
C3 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00”
White
Green
Leadless-Poke-in wire connection
BALLAST
Red
Red
Yellow
Yellow
Blue
Blue
DIAGRAM 4
Series lamp operation
Ballast should be grounded
REFERENCE DRAWING FOR C4
A
B
C
D
E
F
G
Compact Fluorescent
Dwg.
C4 2.98” 1.00” 4.25” 4.61” 4.94” 1.55” 1.00”
Leadless-Poke-in wire connection
Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances
PAGE 3-11
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
2D
LAMPS
• Ideal for surface mount fixtures
•U
niversal input voltage from 120V to 277V.
347V models are also available.
• P rogrammed start for excellent lamp performance
& auto reset shutdown circuit
10, 16 & 21
WATTS
10, 16 AND 21 WATTS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
10 Watts
CFS10W/GR10q
2D, 4-Pin
Lamp Type
16 Watts
CFS16W/GR10q
2D, 4-Pin
Lamp Type
21 Watts
CFS21W/GR10q
2D, 4-Pin
Compact Fluorescent
ELECTRONIC COMPACT
FLUORESCENT BALLASTS
FOR 2D LAMPS
Lead Configuration
Mag Qty Line Starting Min Start
or of Line Catalog✪ Input Current Current Ballast Temp Power Side Multi Multi Starting Wir
Elec Lamps Volt Number Watts Amps Amps Factor (F/C) Factor THD Exit Exit Exit Studs Method✿ Dim Diag
Electrical Characteristics - 60 Hz
120
0.12
>.98 <10%
E 1
C213UNVMEr 15
—— 1.02 0°/-18º
— X
X
PS C3 2a
277
0.06
>.95 <15%
120
0.22
>.98 <10%
E 2
C213UNVMEr 26
—— 1.02 0°/-18º
— X
X
PS C3 3a
277 0.10
>.95 <15%
✱
E 1 347 C213/347ME 16 0.05 —— 1.02 0°/-18º >.95 <10% — X
X
PS C3 2a
E 2 347 C213/347ME✱ 28 0.08 —— 1.02 0°/-18º >.95 <10% — X
X
PS C3 3a
E 1
E 1
E 2
E 2
120
0.15
C213UNVMEr 19
—— 0.95 0°/-18º
277
0.07
✱
347 C213/347ME 20 0.06 —— 0.95 0°/-18º
0.28
120
—— 0.95 0°/-18º
C213UNVMEr 33
277
0.12
347 C213/347ME✱ 34 0.10 —— 0.95 0°/-18º
>.98 <10%
—
>.95 <15%
>.98 <10% —
>.98
<10% —
>.95
>.98 <10% —
120
0.18
E 1
C218UNV◆r 24
—— 0.98 0°/-18º
277
0.08
✱
E 1 347 C218/347ME 21 0.06 —— 0.98 0°/-18º
120
0.37
E 2
C218UNV◆r 43
—— 0.95 0°/-18º
277
0.16
E 2 347 C218/347ME✱ 39 0.12 —— 0.95 0°/-18º
>.98 <10%
—
>.95 <15%
>.98 <10% —
>.98 <10%
—
>.95 <15%
>.98 <10% —
✿ PS = Programmed Start
◆ Add following suffix for complete catalog #: “BE” for Bottom
Exit connectors, "ME" for Multi Exit connectors, or "MES" for
Multi Exit with 2" OC screw studs.
rAdd “000K” suffix for Mult-E Kit. For Distribution only.
✱ Add “001K” suffix for Mult-E Kit. For Distribution only.
X
X
PS C3 2a
X
X
PS C3 2a
X
X
PS C3 3a
X
X
PS C3 3a
X
X
PS C3 2a
X
X
PS C3 2a
X
X
PS C3 3a
X
X
PS C3 3a
All ballasts are UL listed, CSA approved and
designated Class P (thermally protected), Type HL.
See page 3-14 for Dimensions
and Wiring Diagrams.
PAGE 3-12
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
ELECTRONIC COMPACT
FLUORESCENT BALLASTS
FOR 2D LAMPS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
28 Watts
CFS28W/GR10q
2D, 4-Pin
Lamp Type
38 Watts
CFS38W/GR10q
2D
LAMPS
• Ideal for surface mount fixtures
•U
niversal input voltage from 120V to 277V.
• Programmed start for excellent lamp
performance & auto reset shutdown circuit
28 & 38
WATTS
Lead Configuration
Mag Qty
Line Starting Min Start
or of Line Catalog✪ Input Current Current Ballast Temp Power Side Multi Multi Starting Wir
Elec Lamps Volt
Number Watts Amps Amps Factor (F/C) Factor THD Exit Exit Exit Studs Method✿ Dim Diag
Electrical Characteristics - 60 Hz
120
0.27
E 1
C2642UNV◆✱ 31
—— 0.95
0°/-18º >.95 <10% — X X PS C3 2a
277 0.12
✱
E 1 347 C2642/347ME 33 0.10 —— 0.95 0°/-18º >.95 <10% — X
X
PS C3 2a
120
64 0.54
◆
E 2
C242UNV
—— 1.00 0°/-18º >.97 <10% — X
X
PS C4 3a
277
63 0.24
E 2 347 C242/347ME 60 0.18 —— 1.00 0°/-18º >.98 <10% — X
X
PS C4 3a
120
0.27
E 1
C2642UNV◆r 33
—— 0.80
0°/-18º
277 0.12
✿ PS = Programmed Start
◆ Add following suffix for complete catalog #: “BE” for Bottom
Exit connectors, “ME” for Multi Exit connectors, or “MES” for
Multi E
xit with 2” OC screw studs.
rAdd “000K” suffix for Mult-E Kit. For Distribution only.
2D,
4-Pin
✱
Add “001K” suffix for Mult-E Kit. For Distribution only.
>.95 <10% — X
X
PS C3 2a
All ballasts are UL listed, CSA approved and
designated Class P (thermally protected), Type HL.
Compact Fluorescent
See page 3-14 for Dimensions
and Wiring Diagrams.
FOR MORE INFORMATION CALL
PAGE 3-13
1-800-BALLAST
(225-5278)
ELECTRONIC COMPACT FLUORESCENT
BALLASTS FOR 2D LAMPS
2D
LAMPS
WIRING DIAGRAMS AND DIMENSIONS
REFERENCE DRAWING FOR C3
C
WIRING DIAGRAMS
F
A
Install in accordance with
National Electrical Code.
G
B
D
E
Dwg.
A
B
C
D
E
F
G
Black
C3 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00”
White
Green
BALLAST
Leadless-Poke-in wire connection
Red
Red
Blue
Blue
DIAGRAM 2a
REFERENCE DRAWING FOR C4
Black
White
Green
BALLAST
Red
Red
Yellow
Yellow
Blue
Blue
Dwg.
A
B
C
D
E
F
DIAGRAM 3a
Series lamp operation
G
C4 2.98” 1.00” 4.25” 4.61” 4.94” 1.55” 1.00”
Leadless-Poke-in wire connection
Compact Fluorescent
Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances
FOR MORE INFORMATION CALL
PAGE 3-14
1-800-BALLAST
(225-5278)
ELECTRONIC COMPACT
FLUORESCENT BALLASTS
22, 40 & 55 WATTS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
22 Watts
FC9T5-22W
T5 CIRCULAR
Lamp Type
40 Watts
FC12T5-40W
T5 CIRCULAR
Lamp Type
22 & 40 Watts
FC9T5-22W &
FC12T5-40W
T5 CIRCULAR
Lamp Type
55 Watts
FC12T5-55W
• Electronic models feature programmed
start for excellent lamp performance
& auto reset shutdown circuit
22, 40 & 55 WATTS
Lead Configuration
Mag Qty
Line Starting Min Start
or of Line
Catalog✪ Input Current Current Ballast Temp Power Side Multi Multi Starting Wir
Elec Lamps Volt
Number
Watts Amps Amps Factor (F/C) Factor THD Exit Exit Exit Studs Method✿ Dim Diag
Electrical Characteristics - 60 Hz
E 1 347 C2642/347ME✱ 26 0.08 —— 0.98 0°/-18º
120
0.21
E 1
C2642UNV◆r 25
—— 1.00 0°/-18º
277 0.10
E 2 347 C242/347ME 47 0.14 —— 1.05 0°/-18º
1.05 0°/-18º
120
0.42
E 2
C242UNV◆
50
——
277 0.19
E 1 347 C2642/347ME✱ 40 0.12 —— 0.98
0°/-18º
0.35
120
❍ E 1
—— 0.98 0°/-18º
C2642UNV◆r 42
277 0.16
E 2 347 C242/347ME 71 0.22 —— 0.98 0°/-18º
120
80 0.65
❍ E 2
C242UNV◆
—— 0.98 0°/-18º
277
79 0.29
120
E 1+1
C242/347ME 59 0.18 ——
277
120
66 0.54
E 1+1
C242UNV◆
——
277
64 0.24
X
X
PS
C3 2b
>.98 <10% ––
X
X
PS
C3 2b
>.98 <10% ––
X
X
PS
C4 1b
>.95 <10% ––
X
X
PS
C4 1b
>.98 <10% –– X
X
PS C3 2b
>.98 <10% ––
X
PS
>.98 <10% –– X
X
PS C4 1b
>.98 <10% –– X
X
PS C4 1b
0.98 0°/-18º
>.98 <10% –– X
X
PS C4 1b
0.98 0°/-18º
>.97 <10% –– X
X
PS C4 1b
120
0.45
E 1
B2 54PUNV-D 55
—— 1.00 -20/-29
277
0.20
120
0.45
E 1
B254PUNVHB-D 55
—— 1.00 -20/-29
277
0.20
120
51 0.43
E 1
B254PUNVPL-A
—— 1.00 -20/-29
277
50 0.20
120
51 0.43
E 1
B254PUNVPLHBA
—— 1.00 -20/-29
277
50 0.20
120
107 0.88
E 2
B254PUNV-D
—— 1.00 -20/-29
277
104 0.38
120
107 0.88
E 2
B254PUNVHB-D
—— 1.00 -20/-29
277
104 0.38
120
92 0.77
E 2
B254PUNVPL-A
—— 0.96 -20/-29
277
91 0.34
92 0.77
120
B254PUNVPLHBA
—— 0.96 -20/-29
E 2
277
91 0.34
PAGE 3-15
>.98 <10% ––
>.99
>.96
>.99
>.96
>.99
>.91
>.99
>.91
>.99
>.98
>.99
>.98
>.99
>.97
>.99
>.97
X
C3 2b
<10% X
—
—
PS
-D 2b
<10% X
—
—
PS
-D 2b
<10% X
—
—
PS
-A 1b
<10% X
—
—
PS
-A 1b
<10% X
—
—
PS
-D 1b
<10% X
—
—
PS
-D 1b
<10% X
—
—
PS
-A 1b
<10% X
—
—
PS
-A 1b
Compact Fluorescent
T5 CIRCULAR
T5
CIRCULAR
LAMPS
• Ideal for surface mount fixtures
• E lectronic models feature universal input
voltage from 120V to 277V. 347V models
are also available.
LONG TWIN
T5 LAMPS
18, 24/27 WATTS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
18 Watts
FT18W/2G11/RS
• Ideal for track light & surface mount fixtures
• Electronic models feature universal input
voltage from 120V to 277V. 347V models are also
available
• Electronic models feature rapid and programmed
start for excellent lamp performance & auto reset
shutdown circuit
ELECTRONIC COMPACT
FLUORESCENT BALLASTS FOR
LONG TWIN T5 LAMPS
18 AND 24/27 WATTS (BIAX, DULUX L AND PLL)
Lead Configuration
Mag Qty Line Starting Min Start
or
of Line Catalog✪ Input Current Current Ballast Temp Power Side Multi Multi Starting Wir
Elec Lamps Volt
Number Watts Amps Amps Factor (F/C) Factor THD Exit Exit Exit Studs Method✿ Dim Diag
Electrical Characteristics - 60 Hz
120
0.19 ——
— X
X
PS C3 21
E 1
CT218UNVME 23
1.00 0°/-18º >.95 <10%
277
0.07 ——
— X
X
PS C3 21
120
43 0.37 ——
— X
X
PS C3 20
E 2
CT218UNVME
0.98 0°/-18º >.98 <10%
277
42 0.16 ——
— X
X
PS C3 20
Long Twin T5,
4-Pin
120
0.23
>.98 <10%
B224PUNV-C 27
—— 1.05 0°/-18º
X
277
0.10
>.95 <15%
✱
E
1 347 C2642/347ME 29 0.09 —— 0.90 0°/-18º >.95 <10% —
❍
0.22
>.99
120
—— 1.01 0°/-18º
<10% —
E 1
C2642UNVr 26
277
0.10
>.95
120
52
0.43
E 2
B224PUNV-C
—— 1.00 0°/-18º >.98 <10% X
277
51 0.18
Long Twin T5,
E 2 347 C242/347ME 49 0.14 —— 1.02 0°/-18º >.98 <10% —
4-Pin
120
51 0.43
E 2
C242UNV◆
—— 1.02
0°/-18º >.95 <10% —
277
50 0.19
120
47 0.40
>.98
E 2
C2642UNVr
—— 0.98 0°/-18º
<10% —
277
49 0.18
>.99
Lamp Type
24/27 Watts
FT24W/2G11/RS
Compact Fluorescent
Lamp Type
24/27 Watts
CFM24W/2G10
❍ E 1
120
0.20
1
B224PUNV-C 24
—— 1.05 0°/-18º
277
0.09
120
48 0.40
❍ E 2
B224PUNV-C
—— 1.00 0°/-18º
277
47 0.17
❍ E
✿ PS = Programmed Start
❍ Not approved for use in hazardous locations
◆ Add following suffix for complete catalog #: “BE” for Bottom
Exit connectors, “ME” for Multi Exit connectors, or “MES” for
T5 F-Lamp,
Multi Exit with 2” OC screw studs.
4-Pin
rAdd “000K” suffix for Mult-E Kit. For Distribution only.
✱ Add “001K” suffix for Mult-E Kit. For Distribution only.
—
—
PS -C 43
X
X
PS C3 21
X
X
PS C3 21
—
—
PS
X
X
PS C4 20
X
X
PS C4 20
X
X
PS C3 20
>.98 <10%
X —
>.95 <15%
—
PS -C 43
>.98 <10% X
—
PS
—
-C 27
-C 29
All ballasts are UL listed, CSA approved and
designated Class P (thermally protected).
See pages 3-19 and 3-20 for
Dimensions and Wiring Diagrams.
FOR MORE INFORMATION CALL
PAGE 3-16
1-800-BALLAST
(225-5278)
ELECTRONIC
LONG TWIN T5 BALLASTS
36/39 AND 40 WATTS
(BIAX, DULUX L AND PLL)
LONG TWIN
T5 LAMPS
• Ideal for track light & surface mount fixtures
• New electronic 1 & 2 lamp models for 24 watt lamps
• Electronic models feature universal input voltage
from 120V to 277V. 347V models are also available.
• Electronic models feature programmed rapid start for
excellent lamp performance & auto reset shutdown circuit
36/39 & 40
WATTS
QUICK
REFERENCE
Lead Configuration
Mag Qty Line Starting Min Start
or
of Line Catalog✪ Input Current Current Ballast Temp Power Side Multi Multi Starting Wir
Elec Lamps Volt
Number Watts Amps Amps Factor (F/C) Factor THD Exit Exit Exit Studs Method✿ Dim Diag
Lamp Type
Electrical Characteristics - 60 Hz
36/39 Watts
120
0.30 ——
>.98
B224PUNV-C• 36
0.95 0/-18
<10% X
— —
PS -C 43
FT36W/2G11/RS ❍ E 1 277
0.13 ——
>.95
120
0.37
>.99
❍ E 1
B254PUNV-D£ 44
—— 1.20
-20/-29
<10% X —
—
PS -D 43
277
0.17
>.94
120
0.37
>.99
E 1
B254PUNVHB-D 44
—— 1.20
-20/-29
<10% X —
—
PS -D 43
277
0.17
>.94
Long Twin T5,
120
46 0.38
>.99
4-Pin
E 1
B254PUNVPL-A
—— 1.00
-20/-29
<10% X —
—
PS -A A
277
45 0.18
>.90
120
46 0.38
>.99
E 1
B254PUNVPLHBA
—— 1.00
-20/-29
<10% X —
—
PS -A A
277
45 0.18
>.90
120
34 0.29
>.99 < 10%
C242UNV◆
—— 0.88 0/-18
X X
X
PS C4 21
❍ E 1
277
33 0.14
>.90 < 20%
120
71 0.59 ——
>.98
❍ E 2
B239PUNV-D•
0.97 0/-18
<10% X
— —
PS -D 29
277
70 0.26 ——
>.95
120
89 0.70
>.99
❍ E 2
B254PUNV-D
—— 1.10
-20/-29
<10% X —
—
PS -D 29
277
83 0.30
>.97
120
89 0.70
>.99
E 2
B254PUNVHB-D
—— 1.10
-20/-29
<10% X —
—
PS -D 29
277
83 0.30
>.97
120
85 0.71
0.98
>.99
E 2
B254PUNVPL-A
——
-20/-29
<10% X —
—
PS -A A
277
83 0.31 0.96
>.96
120
85 0.71
0.98
>.99
E 2
B254PUNVPLHBA
——
-20/-29
<10% X —
—
PS -A A
277
83 0.31 0.96
>.96
E 2 347 C242/347•◆ 64 0.19 —— 0.90 0/-18 >.98 <10% — X
X
PS C4 20
120 ◆
0.57 ——
>.99
E 2
C242UNV• 64
0.83 0/-18
<10% — X X
PS C4 20
277
0.25 ——
>.97
Nominal lamp watts
and configuration
Lamp Type
36/39 Watts
CFM36W/2G10
FOR MORE INFORMATION CALL
PAGE 3-17
1-800-BALLAST
(225-5278)
Compact Fluorescent
0.28
>.98
120
B224PUNV-C• 34
—— 0.95 0/-18
<10% X
— —
PS -C 43
E 1
277
0.12
>.95
120
0.27 ——
E
1
C2642UNV◆r 32
0.98 0/-18
>.98 <10% —
X
X
PS
C3 21
277 0.12 ——
120
0.28
>.99
E 1
C242UNV◆ 33
—— 0.98 0/-18
<15% — X
X
PS C4 21
277
0.14
>.90
120
68 0.57 ——
T5 F-Lamp,
E 2
C242UNV•◆r
0.90 0/-18
>.95 <10% — X X
PS C4 20
277
67 0.25 ——
4-Pin
Lamp Type
❍ E 1 120 C240SI120RH 43 0.38 —— 1.02 50/10
>.90 <20% X —
—
IS C6 12✛
40 Watts
>.90 <20% X —
—
IS C6 12✛
FT40W/2G11 ❍ E 1 277 C240SI277RH 43 0.17 —— 1.02 50/10
120
41 0.34
E 1
C240PUNVHP-B
—— 1.00 0/-18
>.95 <10% X
—
—
PS -B 21
277 • 40 0.15
120
0.40
>.99
E 1
C242UNV◆
47
—— 1.08 0/-18
<10% — X
X
PS C4 21
277 0.18
>.97
❍
120
76 0.63
Long Twin T5,
E 2
C240PUNVHP-B•
—— 0.90 0/-18
>.98 <10% X
—
—
PS -B 20
4-Pin
❍ 277
73 0.27
❍ E 2 120 C240SI120RH 70 0.59 —— 0.88 50/10
>.95 <20% X —
—
IS C6 12
❍ E 2 277 C240SI277RH 70 0.25 —— 0.88 50/10
>.95 <20% X —
—
IS C6 12
120
>.99
◆ 93 0.78
E 2
C242UNV
—— 1.00 0/-18
<10% — X
X
PS C4 20
277
87 0.34
>.98
E 2 120 C340SI120RH 78 0.68 —— 0.99 50/10 >.90 <20% X —
—
IS C6 14 ✛
E 2 277 C340SI277RH 77 0.28 —— 0.99 50/10 >.90 <20% X —
—
IS C6 14✛
E 3 120 C340SI120RH 104 0.88 —— 0.88 50/10 >.95 <20% X —
—
IS C6 14
E 3 277 C340SI277RH 102 0.37 —— 0.88 50/10 >.95 <10% X —
—
IS C6 14
E 3 347 B332I347HP 97 0.28 —— 0.85 0/-18
>.99 <20% X —
—
IS ST 6
ELECTRONIC
LONG TWIN
T5 LAMPS
• Ideal for track light & recessed fixtures
• Electronic models for 1, 2, 3 & 4 lamp applications
• Programmed Rapid & Instant Starting Options
• Models feature auto reset shutdown circuit
50, 55 & 80 WATTS
ELECTRONIC
LONG TWIN T5 BALLASTS
50, 55 AND 80 WATTS
(BIAX, DULUX L AND PLL)
m
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
50 Watts
FT50W/2G11
Compact Fluorescent
Long Twin T5,
4-Pin
Lamp Type
55 Watts
FT55W/2G11
Long Twin T5,
4-Pin
Lead Configuration
Mag Qty
Line Starting Min Start
or
of Line Catalog✪
Input Current Current Ballast Temp Power Side Multi Multi Starting Wir
Elec Lamps Volt
Number
Watts Amps Amps Factor (F/C) Factor THD Exit Exit Exit Studs Method✿ Dim Diag
Electrical Characteristics - 60 Hz
E 1 347 B254P347-D 58 0.17 —— 1.12
-20/-29 >.95 <10% X — —
PS -D 43
347
0.19
>.95 <10%
E 1
B254PHRVHB-E 65
—— 1.12 -20/-29
X — —
PS -E 42
480 0.15 >.90 <15%
0.47
>.99
120
—— 1.00 -20/-29
<10% X — —
PS -D 43
E 1
B254PUNV-D 57
277
0.21
>.96
120
0.47
>.99
E 1
B254PUNVHB-D 57 0.21
—— 1.00 -20/-29 >.96 <10% X — —
PS -D 43
277
120
59 0.50
>.99
E 1
B254PUNVPL-A1
—— 1.00 -20/-29
<10% X — —
PS -A A
277
58 0.22 >.93
120
59 0.50
>.99
E 1
B254PUNVPLHBA1
—— 1.00 -20/-29
<10% X — —
PS -A A
277
58 0.22 >.93
E 2 347 B254P347-D 106 0.31 —— 1.10
-20/-29 >.98 <10% X — —
PS -D 27
347
115 0.33
>.98
E 2
B254PHRVHB-E
—— 1.10 -20/-29
<10% X — —
PS -E 41
480
114 0.25 >.95
120
111 0.93
>.99
E 2
B254PUNV-D
—— 1.00 -20/-29
<10% X — —
PS -D 29
277
108 0.40
>.98
111 0.93
>.99
120
B254PUNVHB-D
—— 1.00 -20/-29
<10% X — —
PS -D 29
E 2
277
108 0.40
>.98
112 0.95
>.99
120
B254PUNVPL-A1
—— 0.93 -20/-29
<10% X — —
PS -A A
E 2
277
108 0.42 >.97
1
12 0.95
>.99
120
B254PUNVPLHBA1
—— 0.93 -20/-29
<10% X — —
PS -A A
E 2
277
108 0.42 >.97
120
179 1.49
>.98
E 3
B454PUNV-E
—— 1.13 -20/-29
<10% X — —
PS -E 44
277
177 0.64 >.95
120
179 1.49
>.98
E 3
B454PUNVHB-E
—— 1.13
-20/-29 <10% X — —
PS -E 44
277
177 0.64 >.95
159 1.34
>.99
120
B454PUNVPL-E1
—— 0.91 -20/-29
<10% X — —
PS -E B
E 3
277
157 0.58
>.97
120
1
59 1.34
>.99
E 3
B454PUNVPLHBE1
—— 0.91 -20/-29
<10% X — —
PS -E B
277
157 0.58 >.97
120
240 1.98
E 4
B454PUNV-E
—— 1.10
-20/-29
>.98 <10% X — —
PS -E 44
277
235 0.84
120
240 1.98
E 4
B454PUNVHB-E
—— 1.10
-20/-29
>.98 <10% X — —
PS -E 44
277
235 0.84
209 1.76
>.99
120
B454PUNVPL-E1
—— 0.91 -20/-29
<10% X — —
PS -E B
E 4
277
203 0.75
>.98
120
209 1.76
>.99
E 4
B454PUNVPLHBE1
—— 0.91 -20/-29
<10% X — —
PS -E B
277
203 0.75 >.98
E 1 347 B254P347-D 57 0.17 —— 0.92
-20/-29 >.95 <10% X —
—
PS -D 43
347
0.19
>.98 <10%
E 1
B254PHRVHB-E 61 0.14
—— 0.92 -20/-29 >.90 <15% X — —
PS -E 42
480
0.47
>.99
120
—— 1.00 -20/-29 >.96 <10% X — —
PS -D 43
E 1
B254PUNV-D 56 0.21
277
120
0.47
>.99
E 1
B254PUNVHB-D 56 0.21
—— 1.00 -20/-29 >.96 <10% X — —
PS -D 43
277
120
0.49
>.99
E 1
B254PUNVPL-A1 58
—— 1.00 -20/-29
<10% X — —
PS -A A
277 0.22 >.93
120
0.49
>.99
E 1
B254PUNVPLHBA1 58
—— 1.00 -20/-29
<10% X — —
PS -A A
277 0.22 >.93
E 1 347 C242/347ME 43 0.13 —— 0.83 0/-18 >.99 <10% — X
X
PS C4 21
0.38
>.99
120
—— 0.83 0/-18 >.95
<10% — X
X
PS C4 21
E 1
C242UNVu 46 0.17
277
1 Consult factory for availability
FOR MORE INFORMATION CALL
PAGE 3-18
1-800-BALLAST
(225-5278)
MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS
LONG TWIN
T5 LAMPS
DIMENSIONS
QUICK
REFERENCE
Nominal lamp watts
and configuration
Lamp Type
55 Watts
FT55W/2G11
Long Twin T5,
4-Pin
Lead Configuration
Mag Qty
Line Starting Min Start
or
of Line Catalog✪
Input Current Current Ballast Temp Power Side Multi Multi Starting Wir
Elec Lamps Volt
Number
Watts Amps Amps Factor (F/C) Factor THD Exit Exit Exit Studs Method✿ Dim Diag
Electrical Characteristics - 60 Hz
E 2 347 B254P347-D 102 0.30 —— 0.90
-20/-29 >.98 <10% X —
—
PS -D 27
347
109 0.33
>.98
E 2
B254PHRVHB-E
——
0.90 -20/-29
<10% X
—
—
PS -E 41
480
108 0.24 >.95
120
112 0.93
>.99
E 2
B254PUNV-D 109 0.39
—— 1.00 -20/-29 >.98 <10% X — —
PS -D 29
277
112 0.93
>.99
120
B254PUNVHB-D 109 0.39
—— 1.00 -20/-29 >.98 <10% X — —
PS -D 29
E 2
277
120
107 0.89
>.99
E 2
B254PUNVPL-A1
—— 0.93 -20/-29
<10% X — —
PS -A A
277
104 0.38 >.97
120
107 0.89
>.99
E 2
B254PUNVPLHBA1
—— 0.93 -20/-29
<10% X — —
PS -A A
277
104 0.38
>.97
120
174 1.45
>.98
E 3
B454PUNV-E 171 0.62
—— 0.93 -20/-29 >.95 <10% X — —
PS -E 44
277
120
174 1.45
>.98
E 3
B454PUNVHB-E 171 0.62
—— 0.93 -20/-29 >.95 <10% X — —
PS -E 44
277
120
148 1.25
>.99
E 3
B454PUNVPL-E1
—— 0.93 -20/-29
<10% X — —
PS -E B
277
146 0.54
>.97
148 1.25
>.99
120
B454PUNVPLHBE1
—— 0.93 -20/-29
<10% X — —
PS -E B
E 3
277
146 0.54 >.97
120
229 1.91
E 4
B454PUNV-E 223 0.80 —— 0.90 -20/-29 >.98 <10% X —
—
PS -E 44
277
120
229 1.91
E 4
B454PUNVHB-E 223 0.80 —— 0.90 -20/-29 >.98 <10% X —
—
PS -E 44
277
120
191 1.61
>.99
E 4
B454PUNVPL-E1
—— 0.93 -20/-29
<10% X — —
PS -E B
277
187 0.69
>.98
120
1
91 1.61
>.99
E 4
B454PUNVPLHBE1
—— 0.93 -20/-29
<10% X — —
PS -E B
277
187 0.69 >.98
1 Consult factory for availability
REFERENCE DRAWING FOR -B
L
W
H
M
X
Compact Fluorescent
Dwg.
-B 9.50” 1.50” 1.00” 8.89” 0.88”
REFERENCE DRAWING FOR C3
C
REFERENCE DRAWING FOR C4
F
A
G
B
D
E
Dwg.
A
B
C
D
E
F
G
C3 2.31” 1.00” 4.25” 4.61” 4.94” 0.98” 1.00”
Dwg.
A
B
C
D
E
F
Leadless-Poke-in wire connection
G
C4 2.98” 1.00” 4.25” 4.61” 4.94” 1.56” 1.00”
REFERENCE DRAWING FOR C6
Leadless-Poke-in wire connection
REFERENCE DRAWING FOR -D, -E, ESK
Dwg.
L
W
C
A
B
H
M
F
111/16"
5/16"
X
-D 16.88” 1.18” 1.00” 16.20” -- -E 16.88” 1.74” 1.18” 16.28” ---A 9.5” 1.70” 1.18” 8.89” 1.69”
ESK 16.65” 1.24” 1.00” 16.30” --Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances
E
D
PAGE 3-19
Dwg.
A
B
C
D
E
F
C6 2.40” 1.55” 8.31” 8.89” 9.50” 1.19”
Lead Lengths: Side
• Black/White–11˝
• Red/Blue–16˝
• Yellow–16˝
MAGNETIC AND ELECTRONIC
COMPACT FLUORESCENT
BALLASTS
LONG TWIN
T5 LAMPS
WIRING DIAGRAMS
Line
Black
White
BALLAST
Blue
Blue
Red
Black
White
Green
Red
BALLAST
Yellow
Blue
DIAGRAM 12
Parallel lamp operation
;
DIAGRAM 23
Series lamp operation
Cap unused blue lead; insulate to 600 volts.
Line
Black
White
BALLAST
DIAGRAM 42
For one lamp application, individually cap
yellow and yellow/black leads, insulate to 600V
Blue
Blue
Blue
Red
DIAGRAM 27
Series lamp operation
DIAGRAM 43
DIAGRAM 14
Parallel lamp operation
;
Cap unused blue lead; insulate to 600 volts.
Black
White
Green
BALLAST
Red
Blue
Black
Red
White
Green
DIAGRAM 28
Red
Yellow
BALLAST Yellow
Blue
Compact Fluorescent
Blue
DIAGRAM 20
Series lamp operation
Black
Red
White
Red
Green
BALLAST
DIAGRAM 44
DIAGRAM 29
For one lamp operation,
cap blue leads individually,
insulate to 600V.
Blue
Blue
Line
DIAGRAM A
DIAGRAM 41
Mount lamp within 1" of grounded metal reflector.
DIAGRAM 21
For three lamp operation, cap
Blue/White leads individually,
insulate to 600V.
DIAGRAM B
DIAGRAM 50
FOR MORE INFORMATION CALL
PAGE 3-20
1-800-BALLAST
(225-5278)
Notes
Compact Fluorescent
FOR MORE INFORMATION CALL
PAGE 3-21
1-800-BALLAST
(225-5278)
Ballasts For High Intensity
Discharge Lamps
Universal Means Higher
Expectations In High
Intensity Discharge
Universal Lighting Technologies (“Universal”) offers a
wide array of ballasts for High Intensity Discharge (HID)
lamps. Applications include Metal Halide (MH), Pulse
Start Metal Halide (PSMH), and High Pressure Sodium
(HPS) lamps ranging from 35 to 1500 watts.
We’re the technology leader in every category of
HID ballasts. Our Universal Precise™ line is the latest
innovation in magnetic core & coil technology in years.
HID
Universal offers a complete line of HID ballasts for applications ranging from
35 - 1500 watts.
Universal Lighting Technologies is a member of the Panasonic Group
Product Overview
Core & Coil
Core & coil ballasts are used in over 90% of all HID fixtures. Universal’s core & coil models are available for
all HID lamp types, including single-, dual-, tri-, quad- and multi-volt designs. For added
versatility and reduced inventory costs, Universal has also introduced the industry’s first Multi-5™
ballast (120, 208, 240, 277, or 480 volt), featuring a 480-volt tap on a conventional quad-tap ballast.
Our core & coil models are ideal for a wide variety of lighting applications, including factories,
warehouses, gymnasiums and retail stores. All these ballasts feature precision-wound coils, ensuring even
heat dissipation and the highest electrical integrity.
Universal’s Universal Precise™ is the next generation in core & coil technology, featuring a smaller, lightweight design and improved temperature performance. Universal Precise™ fits virtually all
applications, and has no exposed live metal parts. There are no plastic extrusions, which prevents
breakage during shipping. Color-coded leads make installation easy.
50 Hertz
Universal offers 50 Hz core & coil ballasts to meet the rapid growth in demand in international
markets. Our ballasts are available for 220, 230, and 240 volt electrical systems.
HID
F-Can
These ballasts are used primarily for indoor downlighting applications where quiet operation is essential.
All the components of these ballasts are enclosed in a fluorescent-style ballast can and are thermally
protected.
F-Can Ballasts
Core and Coil Ballasts
PAGE 4-2
HID Ballast Kits
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Product Overview
For maximum safety and reliability, all Universal capacitors come with built-in bleed resistors (patented
by Universal) and approved by CSA (CSA file #LR51331, metal cases only). Environmental safety is
assured by use of biodegradable, nontoxic (no PCBs) dielectric fluid (soybean oil), patented by Universal
for use in capacitors. Dry-film capacitors do not include protective devices. Since they can fail in a hazardous manner, it is the responsibility of the purchaser to take appropriate precautions.
Capacitors
Universal has a comprehensive line of capacitors in metal cases (up to 525V ratings) and plastic cases
(up to 400V ratings). All Universal capacitors are designed for 60,000 hours of continuous life. They’re
exceptionally reliable because we put them through accelerated life testing at 125% rated voltage and
rated temperature +10°C.
Universal capacitors are normally packaged with ballasts. They may also be ordered separately, bulk
packaged, or individually boxed with the suffix “BH” (metal cases only). Capacitor weights vary from
1/4 lb. to 1 lb. each.
Dry Capacitors
Type “P” plastic case capacitors described in this section are dry and do NOT contain safety
interrupters (or oil). Plastic cases are UL rated “94V-O” (for use up to 100°C maximum). Type “P”
capacitors are supplied with stranded copper wire leads 8 inches long (18 awg, with 150°C rated insulation). Capacitor rolls are sealed inside plastic cases using epoxy. Design and testing of Universal
capacitors follow specifications in Electronic Industries Association (EIA) Standard 456-A, titled
“Metalized Film Dielectric Capacitors for Alternating Current Application.”
“P” capacitors are designed and rated for continuous duty AC voltages below 400VAC @ 50 or 60 Hz.
Capacitors used with HID ballasts at voltages above 400VAC should contain interrupters (available from
Universal in oval “MF” and round “RMF” oil-filled metal cases).
Plastic Dry Type Capacitors
Metal and Oil Filled Capacitors
HID
Protective Device (Only in metal cases)
Protective device to prevent case rupture
Normal Cover Position
Normal Cover Position
1/2"
1/2"
Barrier
Normal Position of Protective Device
Barrier
Barrier
Position of Protective Device
After Activation
Capacitor Protective
CapacitorDevices
Protective Devices
PAGE 4-3
Barrier
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Oil-Filled Capacitors
VACr
5.0
300
6.0
Part #
Case
Ht (“)
µF
VACr
Part #
Case
Ht (“)
005-1466-BH 1.25 oval
2.2
22.5
300
005-1419-BH 1.50 oval
3.5
300
005-1561-BH 1.25 oval
2.2
24.0
360
005-3160-BH 1.75 oval
3.1
7.0
300
005-1410-BH 1.25 oval
2.2
24.0
400
005-2664-BH 1.75 oval
3.1
8.0
330
005-1411-BH 1.25 oval
2.2
24.0
480
005-2779-BH 1.75 oval
3.9
10.0
330
005-1413-BH 1.25 oval
2.7
24.5
300
005-3278-BH 1.75 oval
2.7
10.0
400
005-1184-BH 1.50 oval
2.7
26.0
330
005-2669-BH 1.75 oval
3.1
10.0
400
005-2167-BH
1.75 dia
2.9
26.0
525
005-2776-BH 1.75 oval
4.3
12.0
300
005-1467-BH 1.25 oval
3.1
28.0
240
005-1886-BH
1.75 dia
2.3
12.0
400
005-2799-BH 1.50 oval
2.7
28.0
300
005-1468-BH 1.75 oval
3.1
12.0
440
005-1464-BH 1.50 oval
3.1
28.0
425
005-1799-BH 1.75 oval
3.9
13.0
300
005-1414-BH 1.25 oval
3.1
30.0
440
005-1475-BH 1.75 oval
3.9
14.0
240
005-1884-BH
1.75 dia
2.3
32.0
300
005-2351-BH 1.75 oval
3.1
14.0
300
005-1415-BH 1.50 oval
2.7
32.0
525
005-1474-BH 2.00 oval
3.9
15.0
400
005-1185-BH 1.75 oval
2.7
33.0
300
005-1470-BH 1.75 oval
3.1
16.0
300
005-1498-BH 1.50 oval
2.7
35.0
330
005-1421-BH 1.75 oval
3.1
17.5
300
005-1417-BH 1.50 oval
3.1
36.0
525
005-2793-BH 2.00 oval
4.3
18.0
440
005-1401-BH 1.75 oval
3.1
40.0
240
005-1887-BH
1.75 dia
2.7
18.5
330
005-1796-BH 1.50 oval
3.1
40.0
300
005-1768-BH 1.75 oval
3.9
20.0
240
005-1885-BH
1.75 dia
2.3
48.0
330
005-1422-BH 1.75 oval
3.9
20.0
330
005-1418-BH 1.50 oval
3.1
52.0
240
005-1888-BH
2.00 dia
2.9
20.5
400
005-3262-BH 1.75 oval
3.1
55.0
240
005-1594-BH 1.75 oval
3.5
21.0
525
005-1495-BH 1.75 oval
3.9
55.0
300
005-2117-BH 1.75 oval
3.9
HID
µF
PAGE 4-4
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Dry Capacitors
-- 100°C Rated
µF V Part #
DIA (“) L (“)
-- 100°C Rated
µF V Part #
DIA (“) L (“)
5.0 280 R17058511-BH 1.26
5.0 280 R17058512-BH 1.26
5.0 330 R17058539-BH 1.26
6.0 280 R17058513-BH 1.26
6.0 280 R17058514-BH 1.26
7.0 280 R17058515-BH 1.65
8.0 300 R17058535-BH 1.65
8.0 330 R17058541-BH 1.65
10.0 280 R17058517-BH 1.26
10.0 280 R17058519-BH 1.65
10.0 330 R17058578-BH 1.65
10.0 400 R17058555-BH 1.65
10.0 400
R17058557-BH 1.65
11.0 400 R17058558-BH 1.65
12.0 300 R17058536-BH 1.65
12.0 330 R17058543-BH 1.65
12.0 400 R17058580-BH 1.65
13.0 330
14.0 170 R17058500-BH 1.26
14.0 280 R17058520-BH 1.65
14.0 280 R17058520-BH 1.65
14.0 400 R17058560-BH 1.65
15.0 400 R17058562-BH 1.65
15.0 400 R17058563-BH 1.85
16.0 280
R17058522-BH 1.65
16.0 280 R17058522-BH 1.65
16.0 330 R17058547-BH 1.65
17.0 400 R17058588-BH 1.65
17.5 280 R17058523-BH 1.65
20.0
20.0
20.0
20.0
20.5
21.0
22.0
22.5
22.5
24.0
24.0
24.0
24.5
26.0
26.5
28.0
28.0
28.0
35.0
35.0
40.0
40.0
48.0
48.0
52.0
52.0
55.0
55.0
55.0
2.36
2.83
2.24
2.36
2.83
2.83
2.83
2.83
2.83
2.83
2.83
2.83
3.82
2.83
2.83
2.83
3.82
2.83
2.83
2.83
3.82
3.82
3.82
2.83
2.83
2.83
3.82
3.82
170 R17058501-BH 1.65
280 R17058526-BH 1.65
330
400 R17058564-BH 1.85
400 R17058565-BH 1.85
400 R17058567-BH 1.85
400 R17058569-BH 1.85
280 R17058527-BH 1.65
280 R17058528-BH 1.65
280 R17058529-BH 1.65
400 R17058571-BH 1.85
400
330 R17058552-BH 1.65
300 R17058537-BH 1.65
400 R17058574-BH 1.85
170 R17058502-BH 1.65
280 R17058530-BH 1.65
330 R17058553-BH
1.85
280 R17058531-BH 1.65
280 R17058532-BH 1.85
240 R17058505-BH 1.65
240 R17058506-BH 1.65
280 R17058533-BH 1.85
330 R17058554-BH 2.05
170 R17058503-BH 1.85
280 R17058534-BH 1.85
240 R17058507-BH 1.85
240 R17058509-BH 1.85
300 R17058538-BH 1.85
2.83
3.82
3.82
3.82
3.82
3.82
3.15
3.82
3.82
3.82
4.76
4.76
4.76
2.83
4.76
3.82
3.82
4.76
3.82
4.76
4.76
4.76
3.82
4.76
3.82
4.76
4.76
HID
PAGE 4-5
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
on center
5.75"
1 Slot
laces
7.75"
2.75"
Bracket Reference Chart
1.75"
on center
2.65"
Bracket B4
0.50"
TYP.
CORE & COIL
WELDED
BRACKETS
CORE & COIL
ADJUSTABLE
MOUNTING
Bracket B4B R A C K E T S
6.10"
on center
0.55"
6.75"
0.50"
5.75"
on center
.640"
7.75"
7.75"
BracketAll welded
B3brackets are .093” thick.
0.75"0.25"
Ref. Drawing ADJ1
.250 Slot
2 Places
1.25" 1.00"
0.75"0.25"
0.75"0.25"
3.35"
0.75"0.25"
1.25" 1.00"
0.30"
3.35"
4.00"
0.30"
3.35"
5.25"
0.30"
Bracket B2
Bracket B1-A
.281 Slot
6 Req.
.281 Slot
2 Places
0.75"0.25"
.250 Slot
2 Places
1.25"
2.65"
6.75"
3.35"
Bracket B1
on center
4.00"
7.75"
0.55"
4.60"
.640"0.50"
7.75"
Ref. Drawing B4
BracketB1-A
B4
Bracket
Bracket B3
2.75"
0.30"
0.70"
2.65" 6.10"
4.60" on
center
5.25"
0.25" Dia.
3 Holes
6.10"
Bracket
B2 B4
Bracket
0.50"
TYP.
7.75"
Bracket B3
0.25" Dia.
20.55"
Holes
6.75"
1.50"
Bracket
B1-B
Bracket
B4
OR
.640"
For use with:
0.25" Dia.
3 Holes
• 50 to 175 watt Mercury, High Pressure
Sodium and
Metal Halide and some 250 watt Metal Halide
Bracket B4
.640"
7.75"
1.50"
0.90"
6.10"
0.55"
0.93"
0.70"
0.70"
.29"
7.75"
7.75"
4.60"
6.75"
on center
5.25"
2.65"
0.58"
on center
0.50"
45º
0.70"
6.10"
on center
3 Holes
0.29"
on center
0.70"
0.25" Dia.
1.30"
1.75"
0.93"
R. TYP.
0.50"
0.09"
.640"
0.50"
R. TYP.
0.55"
0.43"
7.75"
.281 Slot
6 Req.
on center
1.50"
Bracket
B2 B4
Bracket
5.50"
6.75"
on center
1.81"
2.65"
on center
7.75"
on center
1.75"
.281 Slot
6 Req.
0.70"
5.25" 6.75"
0.50"
R. TYP.
Ref. Drawing MB1
1.25"
1.00"
1.75"
2.75"0.25"
R. TYP.
.281 Slot
6 Req.
on center
TYP.
.281 Slot
6 Req.
1.75"
on center
TYP.
Bracket B1-A
Bracket B3
4.00"
7.75"
7.75"
Ref. Drawing B1-B
1.50"
7.75"
TYP.
0.30"
1.25" 1.00"
2.75"
0.50"
3.35"
0.50"
6.10"
Bracket B2
2 Places
0.70"
on center
on center
.281 Slot
2 Places
Ref. Drawing ADJ2 .250 Slot
OR
1.25" 1.00"
0.70"
2.75" 1.75"
0.30"
R. TYP.
4.00"
0.50"
Bracket B1-A
5.25"
Ref. Drawing B3
0.75"0.25"
0.50"
TYP.
1.25"
4.60"
0.30"
4.00"
Bracket B1-A
Bracket B1
.281 Slot
2.75" 1.75" 2 Places
on center
0.75"0.25"
3.35"
3.35"
Bracket B1
4.00"
Ref. Drawing B1-A
0.30"
OR
4.00"
4.60"
0.30"
4.00"3.35"
HID
0.25
3H
Routinely supplied with replacement kits.
Ref. Drawing B2
0.75"0.25" .250 Slot
2 Places
0.30"
0.70"
0.70"
R. TYP.
Bracket B3
Ref. Drawing B1
7.75"
.281 Slot
6 Req.
OR
0.25" Dia.
3 Holes
Ref. Drawing MB2
OR
7.25"
.090"
1.880" .460"
2.685"
1.300"
1.750"
45ϒ
.835"
.290"
.930"
.580"
.290"
OR
.735"
1/4"
Dia.
2 Holes
For use with:
• 250 to 1500 watt Metal Halide
• 250 to 1000 watt High Pressure Sodium and
Mercury Vapor
OR
PAGE 4-6
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
Underwriters’ Laboratories, Inc. Acceptance
All F-Can and Weatherproof ballasts listed in this
catalog are Underwriters’ Laboratories, Inc. white card
listed, except those for 347 volt operation. All Core &
Coil and Potted Core & Coil ballasts listed in this catalog are Underwriters’ Laboratories, Inc.
yellow card listed (component recognized).
Ballast Replacement
Ballast replacement presents the possibility of
exposure to potentially hazardous voltages and should
be performed only by qualified personnel. All installation, inspection and maintenance should be performed
only with the entire circuit power to fixture or equipment turned off. Installation shall be in accordance
with National Electric Code.
Heat
A ballast, like any other electrical device, generates
heat during normal operation. Planning for maximum
heat dissipation with proper fixture design, installation planning and ballast selection will minimize the
possibility of a heat-related problem arising. Excessive
temperature will have an adverse effect on ballast life.
Normal temperature limits:
F-Can Ballasts
Maximum case temperature: 90°C
Potted Core & Coil Ballasts and
Core & Coil Ballasts
Insulation: Class 180°C
Maximum coil temperature: 165°C
(measured by change of resistance method)
temperature. The ballast will continue to cycle until
the cause of overheating is eliminated. If the ballast is
defective, it must be replaced. If the cause is external,
the ballast will resume normal operation after
abnormal conditions are eliminated.
To attain normal ballast life, the maximum coil
temperature of the ballast should not exceed the
rating of the insulation system. A temperature increase
of 10° C results in a 50% reduction of ballast life.
Low Ambient Temperature (cold)
As temperatures drop, less and less vaporized gas is
available within the arc tube of a high intensity
discharge lamp, thereby causing an increase in the open
circuit voltage required to initiate an arc in the lamp,
until a point is reached where the lamp cannot be started. The minimum temperature at which any ballast listed
in this catalog will provide reliable starting is
listed with the electrical characteristics.
Ballasts should be protected from weather, moisture, or
other abnormal atmospheric conditions, unless specifically designed for use under adverse conditions.
Fusing
The purpose of fusing an HID ballast is to remove the ballast
from the power line in the event of a ballast system failure.
A fuse does not protect the ballast from failing.
Because the temperature in the ballast compartment is
high, typically 90OC, fuse ratings are specified at 25OC, and
that this rating declines as the temperature increases, HID
fuse recommendations are made between 2 and 3 times
the maximum current the ballast will draw during all normal
conditions.
All F-Can ballasts listed in this catalog are equipped
with built-in automatic resetting internal thermal
protection as a standard feature.
Fast-blow fuses should not be used due to the possibility of
high inrush currents. These currents are due to the
fact that the power can be applied ant any point in the AC
voltage waveform. Standard and slow-blow are acceptable.
Whenever a ballast with thermal protection is used, it
is imperative that the fixture/ballast/lamp combination
be heat tested under actual or simulated installation
conditions to assure that the ballast will not cycle.
The resetting thermal protector functions as a
thermostat which will open and temporarily
deactivate the ballast when it exceeds the permissible
When using the 120V tap for auxiliary lighting, a slow-blow
fuse should be used to protect the ballast from damage
from a fault in the auxiliary lighting circuit.
HID
REMOTE MOUNTING DISTANCE
Maximum Length in Feet for Remote Mounting of HID Ballasts to Lamp
ANSI
Lamp Type
Watts
12 GA
14 GA
16 GA
18 GA
M57
Metal Halide
175
272
171
107
67
M58
Metal Halide
250
194
122
77
48
M59
Metal Halide
400 132 83 52 33
M47
Metal Halide
1000
196
123
77
48
M48
Metal Halide
1500 146 92 58 36
For proper installation, insure that remote ballasts are properly vented and mounted to a heat-dissipating surface.
PAGE 4-7
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
Sound
High intensity discharge lamp ballasts, like all electromagnetic devices, produce noise, or “hum.” It is the
degree of noise which determines the existence of
a problem. Ballast noise will only be noticeable when
it exceeds the ambient sound level of the installation.
It is obvious that a ballast designed primarily for
outdoor or factory use would not be suitable in an
office environment.
The vast improvements in all high intensity discharge
lamps and ballasts, and their excellent energy
efficiency, have made them viable options for many
indoor applications. The ballasts being considered
should be carefully analyzed to insure that there will
not be an objectionable level of ballast noise.
All F-Can ballasts listed in this catalog are “Sound
Rated” to aid in the selection of a ballast which is
proper for the environment in which it will operate.
Potted Core & Coil ballasts are also designed to
operate at reduced sound levels, generally several
decibels lower than a standard Core & Coil ballast.
Core & Coil ballasts are not sound rated.
HID
In situations where light output necessitates using a
ballast with a sound rating or noise level not normally
acceptable, the ballast should be remotely mounted.
Note, however, that not all ballasts listed in this
catalog are designed or recommended for remote
mounting.
Polarity
Polarity refers to the proper connection of ballast
lead wires to line wires. To aid you in making a
correct installation, Universal ballast leads are
color-coded for easy identification. The white or
yellow ballast lead is to be connected to the neutral
or common. Choose the appropriate ballast voltage
lead to connect to the line.
Grounding
Ballasts and capacitors or starters in metallic casings
must always be grounded. Ballasts and components
may be grounded to the fixture or otherwise
connected to ground. It would be hazardous to make
contact with an ungrounded fixture, ballast or other
electrical component while in operation.
Operating Line Voltage Limits
To receive the full benefits of rated lamp output and
to prolong ballast life, it is essential that the voltage
supplied to an installation be maintained within the
prescribed limits.
In general, the line voltage supplied to a lag type
ballast (reactor or high reactance autotransformer)
should be maintained within 5% of the voltage for
which the ballast is rated. The line voltage to lead type
ballasts (constant wattage autotransformer or constant
wattage isolated) should be maintained within 10%.
Subjecting a ballast to excessive voltage for an
extended period of time results in the deterioration
of the coil insulation. This insulation breakdown will
cause early ballast failure.
Low voltage has no damaging effect on the ballast.
It could, however, have an adverse effect on lamp
performance and starting dependability.
Maintenance
Selecting and installing an adequate and efficient
lighting system means nothing if it is not properly
maintained. Maintenance must always be considered
as part of the life cycle cost of any high intensity
discharge lighting installation in order to assure the
continued performance of the system as originally
specified.
First and foremost in importance is proper lamp
maintenance. High intensity discharge lamps do
not “burn out” like an incandescent bulb, but rather,
undergo changes within the arc tube which prevent
the lamp from starting properly, warming up and
producing full light output. The beginning of
difficulties such as these generally indicates the
end of a lamp’s useful life. Also, a dead lamp left
in a fixture can be very damaging to the ignitor in
systems which utilize them. To overcome this problem,
Universal offers automatic shutoff ignitors, which are
described in the ignitor section of this catalog.
PAGE 4-8
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
In difficult locations, group replacement of all the
lamps, working or not, is often more economical
and convenient than spot replacement. The same,
of course, applies to ballasts which might be
approaching the end of their life. Only you can decide
what is right for your lighting system, but what is
important is that you have a maintenance program.
Periodic cleaning of the fixtures’ lenses and reflectors
is also important in maintaining proper light output.
For indoor systems, maintenance of reflective
surfaces, such as walls and ceilings, will also help
assure proper levels of illumination.
STANDBY LIGHTING AND PACKAGING
Standby Lighting
To provide light during a high intensity discharge
lamp’s warmup period, or the cool-down period
following a power interruption which has
extinguished it, incandescent standby lighting can
be incorporated. This is accomplished by use of a
standby lighting device, or remote, that switches off
an incandescent lamp incorporated into the fixture
once an arc has been established, or reestablished,
in the HID lamp. Generally, standby lighting devices
operate on 120 volts, so a tap must be provided on
ballasts designed to operate at higher line voltages.
The 120 volt terminal or lead on all Universal dual-,
tri-, quad- and multi-volt ballasts can be used as a
tap for standby lighting when the ballast is utilized
for any of the higher voltages. Many single voltage
ballasts are available with a 120 volt tap and are
listed throughout the Core & Coil data section. Other
single voltage ballasts may be available in this
version. Consult our Customer Service Department
for availability and price information.
Packaging
Standard Pack
Universal’s high intensity discharge lamp ballasts
are routinely packed in easy-to-handle cartons
containing from 1 to 20 units per carton, depending
on the size and weight of the ballasts. Consult
Customer Service for the number of “units per carton”
for shipment with attached mounting brackets,
capacitors (for high power factor units), and ignitors
(if required). Other ordering criteria may cause
packaging to vary.
Tray Pack
For the convenience of large quantity users who
request it, Universal ballasts may be packed in trays.
The number of units depends upon the size and weight
of each ballast. These trays are large corrugated
cartons with lids and sides that come off easily.
This type of packaging affords Universal customers a
savings of time and money on their own production
costs. There are fewer cartons to open, break up and
dispose of on the assembly line; warehouse handling
is reduced and inventory control is easier. There is no
additional charge for tray packing.
Individual Cartons
All Distributor Replacement Kits, Weatherproof, Potted
Core & Coil and other larger ballasts are packaged in
individual cartons.
Individual cartons serve a threefold purpose: as a
display carton, a stock package, and a shipping
container for the retail market. Individual cartons may
be packed in master cartons, depending on weight
and size.
Individual carton packaging may be available for other
ballasts. Contact our Customer Service Department for
availability and cost.
PAGE 4-9
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
Any connection to the 120 volt tap must be
accomplished by means of a slow-blow fuse. This
fuse will protect the ballast from abnormal conditions
in the standby lamp circuit or its control device.
The fuse should be located in the coolest place in
the fixture (below 80°C). The recommended fuse
amperage and maximum auxiliary lamp wattage
are listed in this catalog for each ballast suitable
for standby lighting applications. Be sure to follow
the wiring instructions of the standby lighting device
manufacturer. All applicable requirements of the
National Electrical Code must be met.
Nomenclature
UNIVERSAL PRECISE™
ABBREVIATIONS
UL Bench Top Rise Temperature Code
CWA
Constant Wattage Autotransformer
CWI
Constant Wattage Isolated
ISO
Regulated Lag
R-HPF
Reactor—High Power Factor
R-NPF
Reactor—Normal Power Factor
To facilitate UL inspection, the UL Bench Top Rise
Temperature Code is shown on the Universal Core &
Coil Ballast label as 1029X. 1029 is the UL Standard
for HID Ballasts, and the X is the
temperature code. If a fixture is UL listed for 1029D,
then automatically all ballasts with an A, B, C or D
temperature classification are acceptable for use
within that same fixture.
HX-HPF Lag Type — High Reactance
Autotransformer—High Power Factor
UL Bench Top Rise Letter Code
Temperature Range for
Class H (180° C) Ballasts
HX-NPF Lag Type — High Reactance
Autotransformer—Normal Power Factor
B 75°C < 80°C C 80°C < 85°C
A<75°C
D 85°C < 90°C E 90°C < 95°C F 95°C < 100°C
Field
1
2
3
4
5
6
7
8
9
1 1
C 5
1
M
3
0
1
C
Number of Digits
HID
0
0
Container Type
(C/T/I/K)
Wattage
Field
1
A
Pack Code
(000 TO 999)
Lamp Type
(M/P/S/H)
3
M L T
Socket Type & Other
Oddities (M/D/X/L)
Frame Size
(E/3/4/5/X)
Style
(C/F/W/E/I/P)
Circuit Type
(R/A/I/O/L/M)
2 to 4
2 0 0 0
Primary
Voltage
(MLT/ML5/TRI/
48T/120/277/
230)
1
M
Description
1
(M) Metal Halide, (P) Pulse Start Metal Halide, (S) High Pressure Sodium
2
35 to 1500 Watts (Varies from two to four digits)
3
(MLT) Quad, (ML5) Multi-5, (TRI) TriVolt, (48T) 480/120, (120) 120, (277) 277, (230) 230V/50Hz
4
(R) Reactor, (A) CWA, (I) CWI, (O) IsoReg, (L) High Reactance/Lag, (M) MagLag
5
(C), C&C, (F) F-Can, (W) Weatherproof, (E) Encased/Potted C&C (I) Indoor Encased
6
(E) E&I, (3) 3x4, (4) 4-3/4, (5) 5-3/4, (X) Non Core and Coil
7
(M) Mogul or Medium, (D) Double Ended, (L) Low Loss
8
Pack Code (000 to 999, per pack code listing)
9
(C) Carton, (T) Tray, (I) Individual, (K) Kit
PAGE 4-10
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Specifications
TYPICAL SPECIFICATIONS
FOR HID BALLASTS
1. Ballasts shall be designed in accordance with all applicable ANSI specifications including ANSI C82.4.
2 . The Core & Coil ballast shall be designed with class “H” (180°C) or higher insulation system and vacuum
impregnated with a 100% solid based resin.
3 . All coils shall be precision wound.
4 . Core & Coil ballasts shall be designed to operate at least 180 cycles of 12 hours on and 12 hours off, with
the lamp circuit in an open or short-circuited condition and without undue reduction in ballast life.
5. Core & Coil ballast and starter combinations shall be designed to provide a reliable lamp starting down to
-40°C for High Pressure Sodium and Pulse Start Metal Halide and -30°C for Metal Halide and Mercury at
minimum rated line voltage.
6. Manufacturer shall provide written warranty against defects in workmanship, including replacement, for two
years from date of manufacture.
CAPACITORS
1. All capacitors will be provided with a self-contained internal bleeder resistor.
2. All oil-filled capacitors will be housed in corrosion-resistant steel cans and contain .25” quick disconnect
terminals.
3. All capacitors will be supplied by ballast manufacturer.
IGNITORS
1. All ignitors will be epoxy-filled with either a plastic or aluminum external housing.
2. The ignitor shall be so designed to provide six months of lamp open circuit operation without failure.
KITS
1. All HID kits shall be precision wound to insure proper insulation.
2. All HID kits shall be pre-wired.
3. All HID kits shall be built with color-coded leads.
HID
4. All HID kits are to be UL and CSA recognized following the guidelines found in UL 1029 and
CAN/CSA-22.2 No. 74-92 (part 2 and 3).
5. Universal Model __________________________ (or approved equal).
PAGE 4-11
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Distributor Replacement Kits
Universal’s HID distributor replacement kits contain the appropriate core & coil, a properly rated capacitor, and all
other components required for ballast replacement. Our kits are the quickest and easiest to install of any on the
market, thanks to unique design features like:
•
•
•
•
•
Prewired capacitor and ignitor (if required) to save installation time and reduce wiring errors.
Color-coded leads to reduce risk of incorrect wiring inside the fixture.
Features that exceed UL standards, including capacitors that offer trip fault protection.
Simple installation instructions and troubleshooting tips.
UPS shippable box.
Our kit offerings include many quad voltage (120, 208, 240, or 277 volt) and 480 volt core & coil ballasts, as well as
the new Multi-5 five-voltage ballast. 480 volt ballasts are equipped with a 120 volt tap to accommodate stand by
lighting.
Also available for Metal Halide and High Pressure Sodium applications, Universal Lighting’s Multi-5TM Ballast-Lamp
Replacement Kit. This easy to carry convenient all-in-one kit ensures ballast lamp compatibility.
Distributor replacement kit cartons are packaged in master cartons in quantities from 1 to 6 units. Master carton
quantities can be found on Universal’s list and distributor price sheets.
Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits
Wattage
Voltage
Frame Size
Old Part Number
175
120/208/240/277
3 x 4
1130-91R-500K
M175MLTAC3M500K
Multi-5™ Uni-Pak™
175
3 x 4
New
M175ML5AC3M555K
LampType
Metal
Halide
HID
175
250
175
250
Multi-5
480-120
120/208/240/277
Multi-5
250 Multi-5™ Uni-Pak™
250
250
250
480-120
120/208/240/277
Multi-5
3 x 4
3 x 4
1130-31-500K
3 x 4
New
3 x 4
400
400
3 x 4
4.25 x 4.75
4.25 x 4.75
1130-826S-500K
480-120
4.25 x 4.75
1130-33R-500K
Multi-5
4.25 x 5.75
New
Multi-5™ Uni-Pak™ 4.25 x 5.75
1000
1000
1500
1500
New
4.25 x 4.75
New
Multi-5
4.25 x 4.75
1000
1000
1130-32-500K
1130-92R-500K
4.25 x 4.75
New
480-120
120/208/240/277
Multi-5™ Uni-Pak™ 4.25 x 4.75
400
400
1130-92-500K
3 x 4
Multi-5™ Uni-Pak™ 4.25 x 4.75
250
250
New
120/208/240/277
4.25 x 5.75
480-120
4.25 x 5.75
480-120
4.25 x 5.75
120/208/240/277
4.25 x 5.75
1130-32R-500K
1130-93U-500K
New
1130-97-500K
New
1130-57-500K
1130-99R-500K
1130-69R-500K
PAGE 4-12
New Part Number
M175ML5AC3M500K
M17548TAC3M500K
M250MLTAC3M500K
M250ML5AC3M500K
M250ML5AC3M555K
M25048TAC3M500K
M250MLTAC4M500K
M250ML5AC4M500K
M250ML5AC4M555K
M25048TAC4M500K
M400MLTAC4M500K
M400ML5AC4M500K
M400ML5AC4M555K
M40048TAC4M500K
M1000MLTAC5M500K
M1000ML5AC5M500K
M1000ML5AC5M555K
M100048TAC5M500K
M1500MLTAC5M500K
M150048TAC5M500K
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Distributor Replacement Kits
Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits
LampType
Wattage
Voltage
Frame Size
35
120/208/240/277
3 x 4
70
120/208/240/277
3 x 4
50
70
120/208/240/277
100
120/208/240/277
100
100
Pulse Start
150
120/208/240/277
150
175
175
175
120/208/240/277
120/208/240/277
Multi-5
3 x 4
New
M100MLTLC3M
3 x 4
New
3 x 4
New
3 x 4
11310-543-500K
3 x 4
New
3 x 4
New
3 x 4
New
3 x 4
New
3 x 4
New
3 x 4
480-120
4.25 x 5.75
Multi-5
3 x 4
200
200
200
120/208/240/277
480-120
480-120
4.25 x 4.75
320
350
350
350
350
400
400
400
Multi-5
120/208/240/277
Multi-5
480-120
450
120/208/240/277
450
480-120
450
750
750
750
Multi-5
120/208/240/277
Multi-5
480-120
875
120/208/240/277
1000
Multi-5
1000
120/208/240/277
New
New
4.25 x 4.75
New
4.25 x 4.75
480-120
New
1130-827-500K
480-120
Multi-5
New
4.25 x 4.75
4.25 x 4.75
120/208/240/277
New
4.25 x 4.75
Multi-5
Multi-5
New
3 x 4
250
120/208/240/277
New
New
4.25 x 4.75
320
New
3 x 4
120/208/240/277
Multi-5
New
3 x 4
250
250
M70MLTLC3M500K
3 x 4
175
480-120
11310-510-500K
New
4.25 x 5.75
175
M35MLTLC3M500K
4.25 x 4.75
New
New
4.25 x 4.75
1130-829-500K
4.25 x 4.75
New
4.25 x 4.75
4.25 x 5.75
4.25 x 5.75
4.25 x 5.75
4.25 x 5.75
4.25 x 5.75
4.25 x 5.75
PAGE 4-13
M100MLTLC3D500K
M10048TLC3M500K
M150MLTLC3M500K
M150MLTAC3M500K
M150MLTLC3D500K
M15048TLC3M500K
P175MLTAC3M500K
P175MLTAC3L500K
P175ML5AC3M500K
P175MLTAC4L500K
P17548TAC3L500K
P17548TAC4L500K
P200MLTAC3L500K
P200ML5AC3M500K
P20048TAC3L500K
P250MLTAC4L500K
P250ML5AC4L500K
P25048TAC4L500K
P320MLTAC4O500K
P32048TAC4L500K
4.25 x 4.75
4.25 x 4.75
M100MLTLC3O500K
New
1130-622-500K
4.25 x 4.75
M70MLTLC3D500K
P320ML5AC4M500K
P350ML5AC4M
4.25 x 4.75
M7048TLC3M500K
New
4.25 x 4.75
4.25 x 4.75
M50MLTLC3M500K
New
New
New
New
New
New
New
New
New
New
P320ML5AC4L500K
P350MLTAC4M500K
P350ML5AC4O500K
P350ML5AC4L500K
P35048TAC4L500K
P400MLTAC4L500K
P400ML5AC4L500K
P40048TAC4L500K
P450MLTAC4L500K
P450ML5AC4L500K
P45048TAC4L500K
P750MLTAC5M500K
P750ML5AC5M500K
P75048TAC5M500K
P875MLTAC5M500K
P1000MLTAC5M500K
P1000ML5AC5M500K
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
480-120
3 x 4
New Part Number
New
11310-95-500K
120/208/240/277
320
120/208/240/277
3 x 4
175
480-120
120/208/240/277
150
320
120/208/240/277
150
Metal Halide
480-120
70
120/208/240/277
Old Part Number
Distributor Replacement Kits
Quad, 480 Volt, Multi-5™ and Multi-5™ Uni-Pak™ Distributor Replacement Kits
LampType
Wattage
Voltage
Frame Size
50
120/208/240/277
3 x 4
480-120
70
70
120/208/240/277
Old Part Number
New Part Number
12310-95-500K
S50MLTLC3M500K
3 x 4
12310-148R-500K
S7048TLC3M500K
3 x 4
12310-30R-500K
3 x 4
12310-160S-500K
3 x 4
100
120/208/240/277
150
120/208/240/277
200
120/208/240/277
4.25 x 4.75
250
Multi-5
4.25 x 4.75
S250ML5AC4M
4.25 x 4.75
1230-32S-500K
H.P.S.
100
150
200
250
250
480-120
480-120
480-120
120/208/240/277
480-120
3 x 4
12310-153-500K
3 x 4
4.25 x 4.75
4.25 x 4.75
250 Multi-5™ Uni-Pak™ 4.25 x 4.75
400
400
400
400
400
400
Multi-5
4.25 x 4.75
480-120
4.25 x 4.75
120/208/240/277
Multi-5
120/208/240/277
480-120
4.25 x 4.75
4.25 x 5.75
4.25 x 5.75
4.25 x 5.75
Multi-5™ Uni-Pak™ 4.25 x 4.75
400
600
120/208/240/277
4.25 x 5.75
1000
Multi-5
4.25 x 5.75
1000
Multi-5™ Uni-Pak™ 4.25 x 5.75
1000
New
New
1230-92S-500K
New
New
1230-93U-500K
1230-33U-500K
New
1230-93S-500K
1230-33S-500K
New
1000
120/208/240/277
480-120
4.25 x 5.75
4.25 x 5.75
New
New
1230-97S-500K
New
New
1230-57S-500K
S100MLTLC3M500K
S10048TLC3M500K
S150MLTLC3O500K
S15048TLC3M500K
S200MLTAC4M500K
S20048TAC4M500K
S250ML5AC4O500K
S250MLTAC4M500K
S25048TAC4M500K
S250ML5AC4M555K
S400ML5AC4M500K
S400MLTAC4M500K
S40048TAC4M500K
S400ML5AC5M500K
S400MLTAC5M500K
S40048TAC5M500K
S400ML5AC4M555K
S400ML5AC5M555K
S600MLTAC5M500K
S1000MLTAC5M500K
S1000ML5AC5M500K
S1000ML5AC5M555K
S100048TAC5M500K
HID
S150MLTLC3M
Multi-5™ Uni-Pak™ 4.25 x 4.75
400
12310-90-500K
S70MLTLC3M500K
PAGE 4-14
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Distributor Replacement Kits
Canadian Tri-Tap Distributor Replacement Kits
Wattage
Voltage
Frame Size
Old Part Number
New Part Number
175
120/277/347
3 x 4
1130-605-502K
M175TRIAC30502K
250
120/277/347
4.25 x 4.75
1130-593R-502K
M250TRIAC4M502K
120/277/347
4.25 x 5.75
1130-598-502K
LampType
Metal
Halide
250
400
1000
35
1500
50
70
100
175
Pulse Start
Metal Halide
150
200
250
320
350
400
750
70
100
200
H.P.S.
150
250
400
400
1000
120/277/347
120/277/347
120/277/347
120/277/347
120/277/347
120/277/347
120/277/347
120/277/347
120/277/347
120/277/347
3 x 4
4.25 x 4.75
4.25 x 5.75
3 x 4
3 x 4
3 x 4
11310-590-502K
11310-584-502K
3 x 4
New
3 x 4
4.25 x 4.75
120/277/347
120/277/347
120/277/347
New
11310-604-502K
3 x 4
120/277/347
120/277/347
1130-599-502K
3 x 4
4.25 x 4.75
120/277/347
M400TRIAC4M
New
120/277/347
120/277/347
New
New
New
4.25 x 4.75
New
New
4.25 x 4.75
4.25 x 5.75
New
New
3 x 4
12310-579-502K
3 x 4
12310-588-502K
3 x 4
12310-584-502K
120/277/347
4.25 x 4.75
120/277/347
4.25 x 4.75
1230-595U-502K
4.25 x 5.75
1230-598S-502K
120/277/347
120/277/347
120/277/347
4.25 x 4.75
4.25 x 5.75
–
1230-593S-502K
1230-595S-502K
M250TRIAC3M502K
M400TRIAC4O502K
M1000TRIAC5M502K
M1500TRIAC5M502K
M35TRILC3M502K
M50TRILC3M502K
M70TRILC3M502K
M100TRILC3M502K
M150TRILC3M502K
P175TRIAC3M502K
P200TRIAC3M502K
P250TRIAC4M502K
P320TRIAC4M502K
P350TRIAC4M502K
P400TRIAC4M502K
P750TRIAC5M502K
S70TRILC3M502K
S100TRILC3M502K
S150TRILC3M502K
S200TRILC4M502K
S250TRIAC4M502K
S400TRIAC4M502K
S400TRIAC5M502K
S1000TRIAC5M502K
HID
PAGE 4-15
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
MH
175-250
WATT
HID CORE & COIL BALLASTS
METAL HALIDE
• 6 0 Hz
• Minimum starting
temperature: -30° C
• Normal and High Power Factor models available
Nom Dimensions
Capacitor
Ignitor
Max Open Total Max UL
Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 175 WATT M57, M107 METAL HALIDE LAMP
120 or
2.15
5
M175TRIAC30 CWA 211 0.95
305
3 PC1 2.45 3.75 10 400 1.65 3.82 1.56x2.69 2.7 6.8
n/a
n/a
C
277 or
2
347 0.75 2
120 or
1.90
5
A
208 or M175MLTAC3M CWA 213 1.10
3 C
305
1 PC1 2.2
3.6 10 400 1.65 2.83 1.56x2.69 2.7
6.1
n/a
n/a
240 or 0.95 3 B
277 0.85 2 C
120 or 1.90 8
208 or
1.10 5
240 or M175ML5AC3M CWA 208 0.95
300
3
2 PC1 2.3
3.60 10 400 1.65 2.83 1.56x2.69 2.7
6.75
n/a
n/a
B
277 or 0.85 3
480 0.50 2
480 M17548TAC3M
CWA 210 0.51 315 2 4 PC1 2.0 3.3 10 400 1.65 2.83 1.56x2.69 2.7 5.6
n/a
n/a
D
(1) 250 WATT M58 METAL HALIDE LAMP - 4” Frame
120 or 2.8 8 B
277 or M250TRIAC3M CWA 295 1.20 320 3 3 PC1 3.0 4.35 15 400 1.65 3.82 1.91x2.91 2.7 8.0
n/a
n/a
D
347 0.95 3 D
120 or 2.60 8
208 or M250MLTAC3M CWA 297 1.50 315 5 1 PC1 3.0 4.25 15 400 1.65 3.82 1.91x2.91 2.7 9.0
n/a
n/a D
240 or 1.30 4
277 1.10 3
120 or 2.50 8 A
208 or
1.40 5
A
240 or M250ML5AC3M CWA 295 1.25
285
4
2 PC1 3.0
4.5 15 400 1.65 3.82 1.91x2.91 2.7
9.2
n/a
n/a
B
277 or 1.10 3 C
480 0.65 2
B
347 M250347AC3M CWA 295 0.95 320 3 6 PC1 3.0 4.35 15 400 1.65 3.82 1.91x2.91 2.7 8.0
n/a
n/a
D
480 M25048TAC3M CWA 292 0.64 320 2 4 PC1 3.0 4.3 15 400 1.65 3.82 1.91x2.91 2.7 9.0
n/a
n/a
D
Capacitors are available as an option for high power
factor operation.
See page 4-19 for Reference
Drawings and Wiring Diagrams.
HID
CORE & COIL
3
PAGE 4-16
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
METAL HALIDE
•
•
•
•
6 0 Hz
Minimum starting temperature: -30° C
High Power Factor models available
Feature CWA design
MH
250-400
WATT
Nom Dimensions
Capacitor
Ignitor
Max Open Total Max UL
Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 250 WATT M58 METAL HALIDE LAMP - 4.75” Frame
120 or 3.05 8
277 or M250TRIAC4M CWA 290 1.25
305
3
3 PC2 1.63
3.63 15 400 1.65 3.82 1.91x2.91 2.7
9.5
n/a
n/a
B
347 1.05 3
120 or 2.40 8
208 or
1.40
5
310
1 PC2 3.35 3.53 15 400 1.65 3.82 1.91x2.91 2.7 8.0
n/a
n/a
B
M250MLTAC4M CWA 290
240 or
1.20
4
277 1.05 4
120 or 2.42 8
208 or 1.40 5
n/a
n/a
A
240 or M250ML5AC4M CWA 290 1.20 300 4 2 PC2 1.82 3.62 15 360 1.65 3.82 1.91x2.91 2.7 10.8
277 or 1.00 3
480 0.60 2
480
M25048TAC4M CWA 290 0.61 300 2 4 PC2 1.82 3.62 15 360 1.65 3.82 1.91x2.91 2.7 10.8
n/a
n/a
B
(1) 400 WATT M59 METAL HALIDE LAMP
120
M400120AC4M CWA 454 4.00 300
10 5 PC2 2.0
3.86 24 360 1.85 3.82 1.91x2.91 3.1
9.3
n/a
n/a
E
120 or
3.90
10 C
277 or M400TRIAC40 CWA 455 1.70
295
5
3 PC2 2.15
3.90 24 360 1.85
3.82 1.91x2.91 3.1 10.5
n/a
n/a
D
347
1.35 4 D
120 or
4.00
10
208 or
2.30
8
M400MLTAC4M CWA 458
300 1 PC2 2.0 3.86 24 360 1.85 3.82 1.91x2.91 3.1 10.0
n/a
n/a
E
240 or
2.00 5
277
1.70 5
120 or
4.00
10
208 or
2.30 8
240 or M400ML5AC4M CWA 458 2.00 300 5 2 PC2 2.0 3.86 24 360 1.85 3.82 1.91x2.91 3.1 11.0
n/a
n/a
E
277 or
1.70 5
480 1.00 50
480
M40048TAC4M CWA 458 1.00 300 3 4 PC2 2.0 3.9 24 360 1.85 3.82 1.91x2.91 3.1 11.0
n/a
n/a
E
See page 4-19 for Reference
Drawings and Wiring Diagrams.
HID
CORE & COIL
PAGE 4-17
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
MH
1000-1500
WATT
HID CORE & COIL BALLASTS
METAL HALIDEFEATURING MULTI-5™
• 60 HZ.
•M
inimum Starting Temperature: -30° C
• F eature CWA Design
Nom Dimensions
Capacitor
Ignitor
Max Open Total Max UL
Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 1000 WATT M47 METAL HALIDE LAMP
120
M1000120AC5M CWA 1080 9.00 425 23 5 PC3 2.9 4.75 24 480 n/a n/a 1.91x2.91 3.9 18.0
n/a
n/a D
120 or
9.00
20 D
277 or M1000TRIAC5M CWA 1080 3.90 435 10 3 PC3 3.0 4.95 24 480 n/a n/a 1.91x2.91 3.9 19.0
n/a
n/a
D
347 3.20 8 E
120 or
8.95
20
208 or
5.15
15
425
1 PC3 2.9 5.05 24 480 n/a n/a 1.91x2.91 3.9 22.0 n/a n/a D
M1000MLTAC5M CWA 1080
240 or
4.50
10
277
3.90
10
120 or
9.15
20 F
208 or
5.25
15 E
n/a
n/a
E
240 or M1000ML5AC5M CWA 1080 4.55 420 10 2 PC3 2.9 5.05 24 480 n/a n/a 1.91x2.91 3.9 22.0
277 or
3.95
10 E
480 2.30 6 E
480
M100048TAC5M CWA 1080 2.30 410 6 4 PC3 2.85 4.75 24 480 n/a n/a 1.91x2.91 3.9 22.0
n/a
n/a
D
(1) 1500 WATT M48 METAL HALIDE LAMP
120 or
13.70
40
277 or M1500TRIAC5M CWA 1610 6.00 460 20 17 PC3 4.38 6.38 32 525 n/a n/a 1.96x3.65 3.88 29.5
n/a
n/a
G
347 4.70 15
120 or 14.30 40 F
208 or M1500MLTAC5M CWA 1615 8.30 455 25 48 PC3 4.4 6.4 32 525 n/a n/a 1.96x3.65 3.88 30.0
n/a
n/a G
240 or
7.20
20 F
277
6.20
20 E
480 M150048TAC5M CWA 1620 3.50 445 10 15 PC3 4.4 6.4 32 525 n/a n/a 1.96x3.65 3.88 30.0
n/a
n/a
E
HID
CORE & COIL
See page 4-19 for Reference
Drawings and Wiring Diagrams.
PAGE 4-18
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
MH
METAL HALIDE
DESCRIPTION
SUFFIX *
For Ballast Only
For Bracket Only (see pg. 5-7)
For Capacitor Only (see pg. 5-5, 5-6)
For Distributor Replacement Kit
(see pg. 5-13 thru 5-15)
For Canadian Distributor
Replacement Kit (see pg. 5-16)
For Dry-Capacitor & Ballast
(see pg. 5-6)
For Bracket & Capacitor
(see pg. 5-5, 5-7)
For Bracket & Dry-Capacitor
(see pg. 5-6, 5-7)
REFERENCE DRAWING PC1
000
200
500
W
S
M
L
500K
BRef. Dwg.
1
PC1
PC2
PC3
502K
518
700
L
W
M
S
4.00” 0.75” 3.35” 0.25”
5.25” 1.25” 4.60” 0.25”
7.75” 2.75” 6.10” 0.25”
7.75” 2.75” 6.10” 0.25”
See p. 5-7 for adjustable mounting brackets and detailed bracket drawings.
718
REFERENCE DRAWING PC2
REFERENCE DRAWING PC3
4 Holes Cleared
for #10 Thru-Bolts
4 Holes Cleared
for #10 Thru-Bolts
8 Holes Cleared
for #10 Thru-Bolts
A
A
B
MAX
A
B
MAX
B
MAX
2.812˝
2 Holes Cleared
for #10 Thru-Bolts
2.438˝
Bracket
3.500˝ 3.938˝
4.250˝
2 Holes Cleared
for #10 Thru-Bolts
3.875˝
2 Holes Cleared
for #10 Thru-Bolts
4.250˝
4.375˝ 4.750˝
3.875˝
4.375˝
5.375˝ 5.750˝
WIRING DIAGRAMS
Wiring Diagram 1
Wiring Diagram 2
Wiring Diagram 3
Wiring Diagram 4
Wiring Diagram 5
Wiring Diagram 6
HID
CORE & COIL
Wiring Diagram 16
Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances
PAGE 4-19
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
PULSE START
MH
35/39-100 WATT
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
• 6 0 Hz
• Minimum starting temperature: -30° C
• Normal and High Power Factor models available
Nom Dimensions
Capacitor
Ignitor
Max Open Total Max UL
Input Catalog* Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 35/39 WATT M130 METAL HALIDE LAMP
120 or
.84
2
277 or
M35TRILC3M HX-HPF 54
.40
235
1
9 PC1 0.85
2.15 5 300 1.26
2.36 1.31x2.16 2.2
1.7
MH100-3A
5
A
347 .30 1
120 or .82 2
208 or
.48 1
M35MLTLC3M HX-HPF 50
230
10 PC1 0.85 2.0 5 277 1.26 2.83 1.31x2.16 2.2
240 or .42 1
277 .36 1
(1) 50 WATT M110 METAL HALIDE LAMP — Medium Base
120 or
1.30
3
277 or M50TRILC3M HX-HPF 67 .61 250 2 9 PC1 1.05 2.55 6 300 1.26 2.83 1.31x2.16 2.2
347 .48 2
1.25
3
120 or
208 or
0.70 3
255
10 PC1 1.05 2.40 6 300 1.26 2.83 1.31x2.16 2.2
M50MLTLC3M HX-HPF 65
240 or
0.60
2
277 0.55 2
1.7
MH100-3A
5
A
4.25 MH100-3A 10
A
3.6
A
MH100-3A 10
HID
CORE & COIL
(1) 70 WATT M98 / M143 (C98) METAL HALIDE LAMP - Medium Base
120 or 1.85 4
277 or
M70TRILC3M HX-HPF 91
0.80
260
2
9 PC1 1.5
2.65 8 280 1.65
2.83 1.31x2.16 2.2
5.0
MH100-3A
10
A
347 0.65 2
120 or
1.70
4
208 or
1.00 3
M70MLTLC3M
HX-HPF 90
255
10 PC1 1.30 2.65 8 280 1.65 2.83 1.31x2.16 2.2 4.5 MH100-3A 10
A
240 or
0.85 2
277
0.75 2
480
M7048TLC3M HX-HPF 95 0.45 260 1 8 PC1 1.35 2.80 8 300 1.65 2.83 1.31x2.16 2.2 4.2 MH100-3A 10
E
(1) 70 WATT M85 METAL HALIDE LAMP - Double Ended
120 or
1.70 4
208 or
1.00 3
A
255
10 PC1 1.30 2.65 8 280 1.65 2.83 1.31x2.16 4.5 4.25 MH70-3B 10
M70MLTLC3D HX-HPF 90
240 or
0.85 2
277 0.75 2
(1) 100 WATT M90 / M92 / M140 METAL HALIDE LAMP - Medium Base
120 or
2.60
7
277 or
M100TRILC3M HX-HPF 129
1.15
265
3
9 PC1 1.6
2.95 12 280 1.65
2.83 1.31x2.16 3.13
5.5
MH100-3A
10
A
347 0.90 3
120 or
2.60 8
C
1.55
5 C
208 or
M100MLTLC30 HX-HPF 127
260
10 PC1 1.5 2.8 12 280 1.65 2.83 1.31x2.16 n/a 4.5 MH100-3A 10
240 or
1.30 4 B
277
1.15 4 B
480
M10048TLC3M HX-HPF 132
0.62
285
2
8 PC1 1.7
3.0 10 300 1.65
2.83 1.31x2.16 2.7
5.5
MH100-3A
10
C
(1) 100 WATT M91 METAL HALIDE LAMP - Double Ended
120 or
2.60 8
C
208 or
1.55
5 C
M100MLTLC3D HX-HPF 127
260
10 PC1 1.5 2.8 12 280 1.65 2.83 1.31x2.16 3.13 4.5 MH70-3B 10
240 or
1.30 4 B
277
1.15 4 B
3
See page 4-26 for Reference
Drawings and Wiring Diagrams.
Capacitors are available as an option for high power
factor operation.
PAGE 4-20
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
• 60 Hz
•M
inimum Starting Temperature: -40° C
• F eature CWA Design
PULSE START
MH
150-200 WATT
HID
CORE & COIL
Nom Dimensions
Capacitor
Ignitor
Max Open Total Max UL
Input Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 150 WATT M102/M142 METAL HALIDE LAMP - Medium Base
RX-NPF
277 M150277RCEM
171
0.65
277 4 7 5 2.52 3.80 14 280
1.65
2.83
n/a n/a 4.0 MH100-1A 3 B
RX-HPF
120 or
3.32
10
277 or
M150TRILC3M HX-HPF 185
1.48
245
4
9 PC1 2.38
3.65 16 280 1.65
2.83 1.56x2.69 2.7
7.25
MH100-3A
10
D
347 0.65 2
120 or
3.40
10
208 or M150MLTLC3M HX-HPF 185 1.93 260 5
10 PC1 2.38 3.7 16 280 1.65 2.83 1.56x2.69 2.7 7.0 MH100-3A 10
A
240 or
1.70
5
277 1.50 4
120 or
1.60 4 C
208 or M150MLTAC3M
CWA 188
1.00
210
3
1 PCI 2.5
3.75 16 330 1.65
3.82
n/a
n/a
7.1
MH150-1A
10
D
0.80 3 C
240 or
277
0.70 2 C
480
M15048TLC3M HX-HPF 185
1.00
260
3
8 PC1 2.3
3.6 16 280 1.65
2.83 1.56x2.69 2.7
7.0
MH100-3A
10
F
(1) 150 WATT M81 METAL HALIDE LAMP - Double Ended
120 or
3.40
10
208 or
1.95
5
M150MLTLC3D HX-HPF 185
260
10 PC1 2.38 3.70 16 280 1.65 2.83 1.56x2.69 2.7 7.0 MH70-3B 10
A
1.70
5
240 or
277 1.50 4
(1) 175 WATT M152 / M137 METAL HALIDE PULSE START LAMP (4” FRAME)
RX-NPF 1.25
n/a n/a n/a n/a
277 P175277RCEM
199
277 3 7 5 2.5 3.6 12 280
3.9 MH350-1A 10 C
RX-HPF
2.00
1.65 2.83 1.31x2.16 3.9
120 or 2.00 5
277 or P175TRIAC3M CWA 208 0.90
310
2
3 PC1 2.5
3.6 10 400 1.65 2.83 1.31x2.16 3.9
6.75 MH350-1A 10
B
347 0.70 2
120 or 2.09 5
208 or P175MLTAC3M CWA 208 1.26 306 3 1 PC1 2.5 3.6 10 400 1.65 2.83 1.31x2.16 3.9 6.75 MH350-1A 10
A
240 or 1.02 3
277 0.96 2
120 or
1.95
5
208 or P175MLTAC3L CWA 198 1.10
285
3
1 PC1 3.10
4.20 11 370 1.65 2.83
n/a
n/a
8.5
MH350-1A 2
A
240 or
1.00
3
277 0.80 2
120 or 1.80 5
208 or 1.05 3
240 or P175ML5AC3M CWA 210 0.90
295
3
4 PC1 2.65
4.0 10 400 1.65 2.83 1.91x2.91 2.7
8.0
MH350-1A 10
B
277 or 0.80 2
480 0.45 2
480 P17548TAC3L CWA 198 0.50 285 2 2 PC1 3.10 4.20 11 360 1.65 2.83 n/a n/a 8.5 MH350-1A 2
A
(1) 175 WATT M152/M137 METAL HALIDE PULSE START LAMP (5” FRAME)
120 or 1.70 5
208 or P175MLTAC4L CWA 198 0.95 270 3 1 PC2 1.77 3.3 12.5 330 1.65 2.83 n/a
n/a 9.45 MH350-1A 10
A
240 or 0.85 3
277 0.75 2
480 P17548TAC4L CWA 198 0.40 275
2 4 PC2 1.80 3.5 12.5 330 1.65 2.83 n/a
n/a 9.6 MH350-1A 10
A
See page 4-26 for Reference
Drawings and Wiring Diagrams.
PAGE 4-21
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
PULSE START
MH
200-320 WATT
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
• 60 Hz
• Minimum Starting Temperature: -40° C
• CWA and High Power Factor Models Available
HID
CORE & COIL
Nom Dimensions
Capacitor
Ignitor
Max Open Total Max UL
Input Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 200 WATT M136 METAL HALIDE PULSE START LAMP
277 P200277RCEM RX-HPF 218 1.35
277 4 7 5
1.06 2.82 13 280 1.65
3.83
n/a
n/a
4.7
MH350-1A 10 A
120 or 2.70 6
277 or P200TRIAC3M CWA 240 1.04 310 3 3 PC1 2.75 3.95 11 400 1.65 2.83 2.7 3.6 8.0 MH350-1A 10
C
347 0.87 3
120 or
2.10
7
208 or
1.22
5
240 or P200MLTAC3L CWA 227 1.05
245
4
1 PC1 2.90
4.25 15 330 1.85 3.82
n/a
n/a
9.0
MH100-5A 10
A
277 0.95 4
(1) 200 WATT M136 METAL HALIDE PULSE START LAMP
120 or
2.66
6
208 or
1.52
4
240 or P200ML5AC3M CWA 233 1.31
303
3
2 PC1 2.75
4.30 11 400 1.65 2.83
n/a
n/a
8.0
MH350-1A 10
C
277 or
1.12
3
480 0.68 2
480
A
P20048TAC3L CWA 227 0.50 245 2 4 PC1 2.9 4.25 15 330 1.85 3.82 n/a n/a 9.0 MH100-5A 10
(1) 250 WATT M153 METAL HALIDE PULSE START LAMP
RX-NPF 2.00 5
n/a n/a n/a n/a
277 P250277RCEM
278
7 5 1.06 2.82 17.5 280
4.8 MH350-1A 10 A
277
RX-HPF
1.85
5 1.6 3.82 1.56x2.69 3.1
120 or
2.35
8
277 or P250TRIAC4M CWA 300 1.15 292 3 3 PC2 1.36 3.36 14 400 1.6 3.782 2.3 4.0 9.0 MH350-1A 10
A
347 .098 3
120 or
2.40
8
208 or P250MLTAC4L CWA 283 1.40 270 5 1 PC2 2.05 3.90 17 330 1.65 3.82 n/a n/a 11.0 MH350-1A 15
A
240 or
1.20
5
277 1.05 3
120 or
2.50
8
208 or
1.40
5
240 or P250ML5AC4L CWA 283 1.25
270
5
2 PC2 1.85
3.75 17 330 1.65
3.82
n/a
n/a
10.5
MH350-1A 10
A
277 or
1.05
3
480 0.60 2
480 P25048TAC4L CWA 283 0.60 275 2 4 PC2 1.9 3.6 17 360 1.65 3.82 n/a n/a 10.0 MH350-1A 10
A
(1) 320 WATT M132 / M154 METAL HALIDE PULSE START LAMP
RX-NPF 3.70
10
n/a n/a n/a n/a
277 P320277RCEM
348
277
7 5 1.5 3.28 22.5 280
6.8 MH350-1A 10 A
RX-HPF
2.34
6
1.865 3.115
n/a
n/a
120 or
3.85
8
277 or P320TRIAC4M CWA 370 1.70 280 4 3 PC2 2.0 3.73 20.5 360 1.85 3.82 1.91x2.91 3.1 11.0 MH350-1A 10
C
347 1.30 3
120 or
3.10 9 B
A
208 or P320MLTAC40 CWA 364 1.80 275 5 1 PC2 2.0
3.9 21.0 360 1.85 3.82 1.91x2.91 3.1 11.0 MH350-1A 10
240 or
1.55 5 B
277
1.35 4 A
120 or
4.00
10 D
208 or
2.40 7 C
D
240 or P320ML5AC4M CWA 370 2.10 280 5 2 PC2 2.0 3.86 20.5 360 1.8 3.82 1.91x2.91 3.6 11.3 MH350-1A 10
277 or
1.85 5 D
480
1.00 3 C
See page 4-26 for Reference
Drawings and Wiring Diagrams.
PAGE 4-22
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
• 60 Hz
• Minimum Starting Temperature: -40° C
• Feature CWA Design
PULSE START
MH
320-350 WATT
Capacitor
Ignitor
Nom Dimensions
Max Open Total Max UL
Oil Filled
Input Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 320 WATT M132 / M154 METAL HALIDE PULSE START LAMP
120 or
3.10 8
208 or
1.80 5
240 or P320ML5AC4L CWA 363 1.55
275
5
2 PC2 1.88
3.8 21 360 1.85
3.82
2.91
3.13
12.0
MH350-1A 10
A
277 or
1.35 4
480 0.80 3
480
CWA 364 0.80 280 3 4 PC2 2.0 3.9 21 360 1.85 3.82 2.91 3.13 11.0 MH350-1A 10
A
P32048TAC4L
(1) 350 WATT M131 METAL HALIDE PULSE START LAMP
RX-NPF
3.80
10
— — — —
277
377
277
7 5 1.5 3.28 22.5 280
6.8 MH350-1 10 A
P350277RCEM
RX-HPF
2.35
6
1.65 3.82 1.56x2.69 3.9
120 or
4.85
10
277 or
P350TRIAC4M
CWA
405
1.70 280 5 3
PC2
2.0 4.0
21
360
1.85 3.82 2.9 3.1 11.5
MH350-1A
10 C
347 1.30 3
120 or 3.40 9
208 or P350MLTAC4M
2.00
6
CWA 400
275
1
PC2
2.0 3.9
22
360
n/a n/a 2.7 3.9 11.0
MH350-1A
10
C
240 or 1.70 5
277 1.45 4
120 or
3.25
9 B
208 or
1.80
6
1 PC2 1.92
3.95 22.5 345 1.85 3.82
n/a
n/a
10.0 MH350-1A 10
B
P350MLTAC4O CWA 397
270
240 or
1.60
C
5
277 1.40 4 C
120 or 3.35 9
208 or 1.85 6
240 or P350ML5AC4O CWA 397 1.65
280
5
4 PC2 2.2
4.25 22.5 345 1.85 3.82
n/a
n/a
12
MH350-1A 10
B
277 or 1.40 4
480 0.80 3
120 or
3.35
10
208 or 1.90 7
240 or
P350ML5AC4L
CWA
397
1.65 275 9 4
PC2
1.88 3.8
22
360
1.85 3.82 2.69 3.9 12.0 MH350-1A 10 B
277 or 1.45 5
480 0.85 3
480 P35048TAC4O CWA 398 0.85 280
3 4 PC2 2.00 3.95 22.5 345 1.85 3.82 n/a
n/a 11.0 MH350-1A 10
D
480 P35048TAC4L CWA
397
0.85 280 3 4
PC2
2.00 3.9
22
360
1.85 3.82 2.69 3.9 11.0 MH350-1A 10 C
See page 4-26 for Reference
Drawings and Wiring Diagrams.
HID
CORE & COIL
See page 5-29 for Reference
Drawings and Wiring Diagrams.
PAGE 4-23
PULSE START
MH
400 WATT
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
• 60 Hz
•M
inimum Starting Temperature: -40° C
•C
WA and High Power Factor Models Available
Nom Dimensions
Capacitor
Ignitor
Max Open Total Max UL
Input Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 400 WATT M155 / M135 / M128 / M172 METAL HALIDE PULSE START LAMP
120 or
4.05
10
277 or P400TRIAC4M CWA 454 1.75
285
5
3 PC2 2.0
3.9 24 400 1.85 3.82 1.91x2.91 3.1
12 MH350-1A 10
D
347 1.40 4
120 or
3.90
10 B
208 or P400MLTAC4L CWA 454 2.25
280
7
1 PC2 2.30
4.20 26 330 1.85 3.82
n/a
n/a
11
MH350-1A 10
B
240 or 1.95 5 B
277 1.70 5 C
120 or
3.90
10
208 or
2.25
7
240 or P400ML5AC4M CWA 457 1.95
285
5 26 PC2 2.0
3.9 24 400 1.85 3.82 1.91x2.91 3.1
12.5 MH350-1A 10
D
277 or
1.70
5
480 0.95 3
120 or
3.90
10 C
208 or 2.25 7 D
240 or P400ML5AC4L CWA 454 1.90
280
5
2 PC2 2.35
4.25 26 330 1.85 3.82 1.91x2.91 3.1
12
MH350-1A 10
C
277 or 1.65 5 C
480 0.95 3 D
480
P40048TAC4L CWA 454 1.00 285 3 4 PC2 2.35 4.25 26 330 1.85 3.82 n/a n/a 12.5 MH350-1A 10
D
480
P40048TAC4M CWA 457 1.00 285 3 4 PC2 2.0 3.9 24 400 1.85 3.82 1.91x2.91 3.1 12 MH350-1A 10
D
HID
CORE & COIL
See page 4-26 for Reference
Drawings and Wiring Diagrams.
PAGE 4-24
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
• 60 Hz
•M
inimum Starting Temperature: -40° C
•C
WA and High Power Factor Models Available
PULSE START
MH
450-1000 WATT
See page 4-26 for Reference
Drawings and Wiring Diagrams.
PAGE 4-25
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
CORE & COIL
Nom Dimensions
Capacitor
Ignitor
Max Open Total Max UL
Input Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 450 WATT M144 METAL HALIDE PULSE START LAMP
120 or
4.35
10 B
208 or
2.55
8
C
280
1 PC2 2.25 4.0 26.5 400 1.85 4.76 1.91x2.91 3.9 13.0 MH350-1A 10
P450MLTAC4L CWA 508
240 or
2.15
7
C
277
1.90
5
C
120 or
4.10
12 C
208 or 2.35 8 B
240 or P450ML5AC4L CWA 508 2.05
280
7
2 PC2 2.65
4.55 26.5 360 1.85 4.76 1.91x2.91 3.9
15.5
MH350-1
10
C
277 or 1.85 5 C
480 1.05 4 B
480 P45048TAC4L CWA 511 1.05 277 3 4 PC2 2.40 4.25 26.5 360 1.85 4.76 1.91x2.91 3.9 14.5 MH350-1A 10
D
(1) 750 WATT M149 METAL HALIDE PULSE START LAMP
120 or
7.05
15 B
277 or P750TRIAC5M CWA 820 3.05
340
8
3 PC3 2.8
4.6 28 400 n/a
n/a 1.91x2.91 3.88 18.0
P750-1B
10
C
347 2.45 8 C
120 or
7.10
18 D
A
208 or
4.10
10
340
1 PC3 2.8 4.8 28 400 n/a n/a 1.91x2.91 3.88 18.0 P750-1B 10
P750MLTAC5M CWA 825
240 or
3.55
10 B
277 3.10 8 B
120 or
6.95
18 C
208 or
4.00
10 C
240 or P750ML5AC5M
CWA 820 3.50
340
10
2 PC3 2.8
4.9 28 400
n/a
n/a 1.91x2.91 3.88 19.0 P750-1B 15 D
277 or
3.00 8 D
480
1.75 5 C
480 P75048TAC5M CWA 822 1.80 335 5 4 PC3 2.8 4.75 28 400 n/a n/a 1.91x2.91 3.88 18.0 P750-1B 10
D
(1) 875 WATT M166 METAL HALIDE PULSE START LAMP
120 or
7.90
20 D
C
208 or
4.55
15
395
1 PC3 2.8 4.8 24 480 n/a n/a 1.91x2.91 3.9 17.5 HPS1000-4B 10
P875MLTAC5M CWA 945
240 or
3.95
10 A
277
3.45
10 C
(1) 1000 WATT M141 METAL HALIDE PULSE START LAMP
120 or
9.00
20
208 or
5.20
15
420
1 PC3 2.9
5.05 24 480 n/a
n/a 1.91x2.91 3.9
22.0 HPS1000-4B 20
D
P1000MLTAC5M CWA 1080
4.50
10
240 or
277
3.90
10
120 or
8.95
20 G
208 or
5.15
15 B
240 or P1000ML5AC5M CWA 1080 4.45 420 10 2 PC3 2.9 5.05 24 480 n/a n/a 1.91x2.91 3.9 22.0 HPS1000-4B 20
C
277 or
3.85
10 C
480
2.25
10 C
480 P100048TAC5M CWA 1080 2.30 410 6 4 PC3 2.85 4.75 24 480 n/a n/a 1.91x2.91 3.9 18.0 HPS1000-4B 15
D2
PULSE START
MH
HID CORE & COIL BALLASTS
PULSE START METAL HALIDE
DESCRIPTION
SUFFIX *
For Ballast Only
For Bracket Only (see pg. 5-7)
For Capacitor Only (see pg. 5-5, 5-6)
For Distributor Replacement Kit
(see pg. 5-13 thru 5-15)
For Canadian Distributor
Replacement Kit (see pg. 5-16)
For Dry-Capacitor & Ballast
(see pg. 5-6)
For Bracket & Capacitor
(see pg. 5-5, 5-7)
For Bracket & Dry-Capacitor
(see pg. 5-6, 5-7)
000
200
500
REFERENCE DRAWING PC1
REFERENCE DRAWING PC2
4 Holes Cleared
for #10 Thru-Bolts
4 Holes Cleared
for #10 Thru-Bolts
A
A
B
MAX
B
MAX
2.812˝
2 Holes Cleared
for #10 Thru-Bolts
500K
502K
3.875˝
2.438˝
3.500˝ 3.938˝
4.250˝
2 Holes Cleared
for #10 Thru-Bolts
4.375˝ 4.750˝
518
700
REFERENCE DRAWING PC3
718
REFERENCE DRAWING 5
8 Holes Cleared
for #10 Thru-Bolts
A
B
MAX
W
Bracket
2 Holes Cleared
for #10 Thru-Bolts
S
M
L
BRef. Dwg.
PC1
PC2
PC3
RX1
4.250˝
L
W
M
S
5.25” 1.25” 4.60” 0.25”
7.75” 1.25” 5.75” 0.25”
7.75” 2.75” 6.10” 0.25”
4.00” 0.75” 3.35” 0.25”
3.875˝
4.375˝
5.375˝ 5.750˝
See p. 5-7 for adjustable mounting brackets and detailed bracket drawings.
HID
CORE & COIL
WIRING DIAGRAMS
Wiring Diagram 1
Wiring Diagram 2
Wiring Diagram 3
Wiring Diagram 4
Wiring Diagram 7
Wiring Diagram 8
Wiring Diagram 10
Wiring Diagram 9
Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances
PAGE 4-26
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUM
HPS
35-100
• 60 Hz
• Minimum Starting Temperature: -40° C
• Normal and High Power Factor Models
WATT
1
Also can be used on a 277 volt line in conjuction with the step down transformers
Capacitors are available as an option for High Power Factor operation
◆
Ballast has built-in starter.
3
PAGE 4-27
See pages 4-31 and 4-32 for
Reference Drawings and Wiring Diagrams.
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
CORE & COIL
Nom Dimensions
Capacitor
Ignitor
Max Open Total Max UL
Input Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 35 WATT S76 HIGH PRESSURE SODIUM LAMP
0.65
2
HPS150-3A
1201 1233-251W ◆ R-HPF 3 43
120
11 1 0.63 2.0 14 120 1.87 2.25 1.56x2.69 2.7 1.5
3 A
1.15 3 Permanently Attached
RX-NPF 0.85 120 2
120 S35120RCEM
44
7 5 0.55 1.75 14 220 1.87 2.25 1.9 2.3 1.2 HPS150-3A 10
A
RX-HPF 0.65 3
(1) 50 WATT S68 HIGH PRESSURE SODIUM LAMP
0.90
3
HPS150-3A
1201
1233-35W ◆ R-HPF 3 60
120
11 1 0.94 2.40 20 120 1.65 2.83 1.56x2.69 3.1 2.0
3 A
1.50 5 Permanently Attached
RX-NPF 0.90 3
120 S50120RCEM
60
120
7 5 0.83 1.95 20 240 1.87 2.25 1.9 2.3 1.5 HPS150-3A 3
A
RX-HPF 1.10
4
120 or
1.24
5
208 or
0.60 3
130
10
PC1
1.3 2.7
5
300
1.2 2.2 2.2 2.2 4.1 HPS150-3A
5 A
S50MLTLC3M HX-HPF 66
240 or
0.52
3
277 0.45 2
(1) 70 WATT S62 HIGH PRESSURE SODIUM LAMP
1.30
8
HPS150-3A
120 1233-142W ◆ R-HPF 83
120
11 1 1.32 2.7 2.8 120 1.65 4.75 n/a n/a 2.5
3 A
Permanently Attached
2.10 8
RX-NPF 1.30 4
120 S70120RCEM
82
120
7 5 1.10 2.25 28 120 1.87 2.25 1.3 2.7 2.0 HPS150-3A 3
A
RX-HPF 210 6
120 or
1.50
4
B
277 or S70TRILC3M HX-HPF 94 0.65 120 2 9 PC1 1.38 2.7 7 280 1.65 2.83 1.31x2.16 2.2 4.4 HPS150-3A 10
A
347
0.50
2
A
120 or 1.50 5
208 or S70MLTLC3M HX-HPF 98 0.88 120 3 10 PC1 1.38 2.74 7 280 1.65 2.83 1.31x2.16 2.2 4.1 HPS150-3A 10
B
240 or 0.75 3
277 0.65 2
480
S7048TLC3M HX-HPF 94 0.34 120 2 8 PC1 1.85 3.0 7 280 1.65 3.00 1.31x2.16 2.2 6.0 HPS150-3A 10
A
(1) 100 WATT S54 HIGH PRESSURE SODIUM LAMP - 1.80
5
HPS150-3A
120 1
1233-10W ◆ R-HPF 3 114
120
11 1 1.5 2.9 40 120 1.87 2.78 1.87 2.9 2.8
3 A
2.90 8 Permanently Attached
RX-NPF 2.90 8
120 S100120RCEM
115
120
7 5 1.50 2.75 40 120 1.87 2.78 1.8 2.7 2.0 HPS150-3A 10
A
RX-HPF 1.80 5
120 or 2.20 8
277 or S100TRILC3M HX-HPF 130 0.95
120
3
9 PC1 2.0
3.5 10 330 1.2
2.7 1.31x2.16 2.7
5.9 HPS150-3A 10
B
347 0.69 2
120 or 2.20 7
208 or S100MLTLC3M HX-HPF 122 1.30
120 5 10 PC1 2.0 3.36 10 280 1.26 2.83 1.31x2.16 2.7 6.0 HPS150-3A 10
B
240 or 1.10 3
277 0.95 3
480
S10048TLC3M HX-HPF 132 0.57 120
2 8 PC1 2.0
3.3 10 280 1.26 2.83 1.31x2.16 2.2
6.0 HPS150-3A 5
E
HPS
150-250
HID
CORE & COIL
WATT
HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUM
• 60 Hz
• Minimum Starting Temperature: -40° C
• CWA, Normal and High Power Factor Models
Nom Dimensions
Capacitor
Ignitor
Max Open Total Max UL
Input Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 150 WATT S55 HIGH PRESSURE SODIUM LAMP
2.35
6
HPS150-3A
1233-154W ◆ R-HPF 3 170
120 1
120
11 1 2.0 3.4 52 240 1.85 3.82 2.12 2.9 3.5
3 A
Permanently Attached
4.40
12
RX-NPF 2.35
12
120 S150120RCEM
170
120
7 5 2.0 3.05 50 120 1.87 n/a 2.0 2.9 3.25 HPS150-3A 3
A
RX-HPF 4.40 6
120 or
3.10 10
B
S15027TLC3M HX-HPF 188
120
12 PC1 2.5 3.85 14 280 1.65 2.83 1.56x2.69 2.7 7.0 HPS150-3A 10
277 1.30 5 A
120 or
3.00
10 B
277 or S150TRILC3M HX-HPF 188 1.35 120 5 9 PC1 2.38 3.68 14 300 1.6 2.8 1.56x2.69 2.7 7.0 HPS150-3A 10
C
347
1.00 4 B
120 or
3.00
10 E
208 or S150MLTLC3O HX-HPF 188 1.65 120 5 10 PC1 2.5 3.85 14 280 1.6 2.8 2.7 2.7 7.0 HPS150-3A 10 D
240 or
1.50 5 E
277
1.30 4 D
480
S15048TLC3M HX-HPF 189 0.72 120 2 8 PC1 3.0 4.5 14 280 1.6 2.83 1.56x2.69 2.7 8.75 HPS150-3A 10
D
(1) 200 WATT S66 HIGH PRESSURE SODIUM LAMP
120
2.00
7
277 S200TRIAC4M CWA 240 0.86 184 3 3 PC2 1.45 3.25 28 280 1.65 4.76 1.91x2.91 3.1 8.65 HPS400-3A 10
C
347
0.68
3
120 or
2.10 7
208 or
1.20 4
CWA 240
175
1 PC2 1.2 3.0 28 280 1.65 4.76 1.91X2.91 3.1 8.5 HPS400-3A 10
S200MLTAC4M
B
240 or
1.00 4
277 0.88 4
480 S20048TAC4M CWA 240 0.56 172 2 4 PC2 1.2 3.0 28 280 1.65 4.76 1.91x2.91 3.1 8.5 HPS400-3A 10
C
(1) 250 WATT S50 HIGH PRESSURE SODIUM LAMP
120 S250120AC4M CWA 295 2.50 185 8 13 PC2 1.8 3.65 35 330 n/a n/a 1.8 3.1 10.3 HPS400-3A 10
A
120 or 2.40 7 B
277 or S250TRIAC4M CWA 295 1.05 185 3 3 PC2 1.8 3.55 35 240 1.65 3.82 1.91x2.91 3.1 10 HPS400-3A 10
B
347 0.85 3 C
120 or 2.50 7
208 or
1.45
4
S250MLTAC4M CWA 295
190 1 PC2 1.8 3.55 35 240 1.65 3.82 1.91x2.91 3.1 10 HPS400-3A 10
B
240 or 1.25 4
277 1.10 3
120 or 2.50 8 C
208 or 1.55 4 C
240 or S250ML5AC4O CWA 300 1.25 188 4 2 PC2 1.95 3.70 35 240 1.65 3.82 1.91x2.91 3.1 11 HPS400-3A 10
B
277 or 1.05 3 B
480 0.65 2 B
480 S25048TAC4M CWA 298 0.65 190 2 4 PC2 1.85 3.65 35 240 1.65 3.82 1.91x2.91 3.1 10 HPS400-3A 5
A
See pages 4-31 and 4-32 for
Reference Drawings and Wiring Diagrams.
Ballast has built-in starter.
* Also can be used on a 277 volt line in conjunction with
the step-down transformers described on page 5-53.
3
Capacitors are available as an option for high power
factor operation.
◆
PAGE 4-28
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUMFEATURING MULTI-5™
• 60 Hz
• Minimum Starting Temperature: -40° C
• CWA, Normal and High Power Factors Models Available
HPS
400-430
WATT
Nom Dimensions
Capacitor
Ignitor
Max Open Total Max UL
Input Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP - 4 3/ ” Frame
120 or
3.95
10
277 or S400TRIAC4M CWA 465 1.70 190 5 3 PC2 2.32 4.1 55 240 1.77 3.74 1.91x2.91 3.5 14.0 HPS400-3A 10
D
347 1.35 4
120 or
3.80
10
208 or
2.20
6
S400MLTAC4M CWA 463
190
1 PC2 2.32 4.1 55 240 1.77 3.74 1.91x2.91 3.5 14.0 HPS400-3A 10
D
240 or 1.90 5
277 1.90 5
120 or
3.95
10
208 or
2.30
6
240 or S400ML5AC4M CWA 465 2.00
190
5
2 PC2 2.44
4.3 55 240 1.77 3.74 1.91x2.91 3.5
14.0 HPS400-3A 10
D
277 or 1.70 5
480 1.00 3
480 S40048TAC4M CWA 464 1.00 190 3 4 PC2 2.32 4.1 55 240 1.77 3.74 1.91x2.91 3.5 14.0 HPS400-3A 10
D
(1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP - 5 3/ ” Frame
120 or
3.90
10
277 or S400TRIAC5M CWA 467 1.70 200 5 3 PC2 2.2 4.1 48 280 2.05 4.76 1.91x2.91 3.9 16.0 HPS400-3A 10
E
347 1.35 4
120 or
3.95
10
208 or
2.30
6
200
1 PC3 2.25 4.1 48 280 2.05 4.76 1.91x2.91 3.9 16.0 HPS400-3A 10
D
S400MLTAC5M CWA 465
240 or 2.00 5
277 1.70 5
120 or
4.00
10
208 or
2.30 6
240 or S400ML5AC5M CWA 468 2.00
200
5
2 PC3 2.5
4.5 48 300 2.05 4.76 1.91x2.91 3.9
17.5 HPS400-3A 10
D
277 or
1.75
5
480 1.00 3
480
S40048TAC5M CWA 467 1.00 200 3 4 PC3 2.25 4.1 48 280 2.05 4.76 1.91x2.91 3.9 16.0 HPS400-3A 10
D
(1) 430 WATT SON AGRO HIGH PRESSURE SODIUM LAMP
120 or
4.50
10
208 or
2.50
8
205
1 PC2 2.25 4.25 48 330 2.0 4.7 1.91x2.91 3.9 11.0 HPS400-3A 10
D
S430MLTAC4M CWA 490
240 or 2.10 7
277 1.80 5
4
4
3
Capacitors are available as an option for high power
factor operation.
See pages 4-31 and 4-32 for
Reference Drawings and Wiring Diagrams.
HID
CORE & COIL
PAGE 4-29
HPS
600-1000
WATTS
HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUM
• 6 0 Hz
• Minimum Starting Temperature: -40° C
• C
WA models available
Nom Dimensions
Capacitor
Ignitor
Max Open Total Max UL
Input Catalog*
Circuit Watts Input Circuit Fuse Wir Ref Min Dry Film
Oil Filled
Weight Catalog Distance Bench
Volts
Number
Type Input Current Voltage Rating Dia Dwg A
B µF Volt Dia
Ht Oval
Ht (lbs.) Number to lamp (ft) Top Rise
(1) 600 WATT S106 HIGH PRESSURE SODIUM LAMP
120 or
5.10 20
208 or
3.10
15
CWA 640
240
1 PC3 3.0 5.0 55 300 1.8 4.7 1.91x2.91 3.9 21.0 HPS600-1B 10
A
S600MLTAC5M
240 or
2.70
10
277 2.35 10
(1) 1000 WATT S52 HIGH PRESSURE SODIUM LAMP
120 or
9.50
24
S100024TAC5M CWA 1100
440
14 PC3 3.8 5.7 26 525 n/a n/a 1.91x2.91 4.25 26.0 HPS1000-4B 15
C
240 4.80 12
120 or 9.60 20
277 or S1000TRIAC5M CWA 1100 4.30 440 10 3 PC3 3.8 5.75 26 525 n/a n/a 1.91x2.91 4.25 27.0 HPS1000-4B 15 D
347 3.40 10
120 or 9.50 24
208 or S1000MLTAC5M CWA 1100 5.50 440 15 1 PC3 3.8 5.7 26 525 n/a n/a 1.91x2.91 4.25 26.0 HPS1000-4B 15 C
240 or 4.80 12
277 4.20 10
120 or
9.45
20
208 or
5.45
15
S1000ML5AC5M
240 or
CWA 1048 4.75 440 10 2 PC3 3.75 5.65 26 525 n/a n/a 1.91x2.91 4.25 26.0 HPS1000-4B 15
D
277 or
4.10
10
480 2.35 8
480 S1000480AC5M CWA 1100 2.45 440 8 4 PC3 3.8 5.7 26 525 n/a n/a 1.91x2.91 4.25 25.0 HPS1000-4B 15
D
480 S100048TAC5M CWA 1100 2.45 440 8 4 PC3 3.8 5.7 26 525 n/a n/a 1.91x2.91 4.25 25.0 HPS1000-4B 15 D
HID
CORE & COIL
See pages 4-31 and 4-32 for
Reference Drawings and Wiring Diagrams.
PAGE 4-30
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HPS
HID CORE & COIL BALLASTS
HIGH PRESSURE SODIUM
DESCRIPTION
SUFFIX *
For Ballast Only
For Bracket Only (see pg. 5-7)
For Capacitor Only (see pg. 5-5, 5-6)
For Distributor Replacement Kit
(see pg. 5-13 thru 5-15)
For Canadian Distributor
Replacement Kit (see pg. 5-16)
For Dry-Capacitor & Ballast
(see pg. 5-6)
For Bracket & Capacitor
(see pg. 5-5, 5-7)
For Bracket & Dry-Capacitor
(see pg. 5-6, 5-7)
000
200
500
Bracket
W
500K
M
L
502K
BRef. Dwg.
1, 1a, 5
PC1, 4
PC2, PC3
518
700
L
W
M
S
4.00” 0.75” 3.35” 0.25”
5.25” 1.25” 4.60” 0.25”
7.75” 1.25” 5.75” 0.25”
See p. 5-7 for adjustable mounting brackets and detailed bracket drawings.
718
REFERENCE DRAWING 1
2.625"
0.438"
A
.203" Dia Thru
4 Holes
S
B
A
2.188"
B
REFERENCE DRAWING 5
0.438"
.199" Dia Thru
4 Holes
.250" Dia Thru
2 Holes
0.594"
0.594"
0.438"
0.438"
A
0.437"
B
A
.250" Dia Thru
2 Holes
1.750"
2.188"
2.437"
1.750"
2.188"
2.188"
2.812"
1.218"
2.625"
REFERENCE DRAWING PC1
REFERENCE DRAWING PC2
A
B
2.812˝
.250" Dia Thru
2 Holes Cleared
2 Holes
for #10 Thru-Bolts
2.438˝
3.875"
4.250"
1.937"
0.637"
.250" Dia Thru
B
4 Holes
MAX
A
MAX
3.500˝ 3.938˝
B
4.250˝
4.375˝ 4.750˝
.250"
8
B
.250" Dia Thru
2 Holes
2 Holes Cleared
for #10 Thru-Bolts
3.875"
4.250"
4.375"
A
A
.250" Dia Thru
2 Holes
Four 0.250"
Male Quick
Connect
Terminals
3.875˝
4.250˝
1.937"
4.750"
4.750"
3.875˝
4.375"
4.375˝
5.375˝ 5.750˝
3.875"
4.250" 1.937"
5.375"
5.750"
Reference Drawing
7
0.625"
.250" Dia Thru
8 Holes
0.687"
A
.218" Dia Thru
4 Holes
B
A
B
1.062"
.250" Dia Thru
2 Holes
HID
CORE & COIL
Reference Drawing
6
Reference
Drawing
Note: Nominal
dimensions
provided above
5 for drawings and/or tolerances
Contact Universal
0.625"
.250" Dia Thru
8 Holes
8 Holes Cleared
for #10 Thru-Bolts
0.637"
B
.250" Dia Thru
8 HolesMAX
A
A
2 Holes Cleared
for #10 Thru-Bolts
3.875"
REFERENCE DRAWING PC3
4 Holes Cleared
for #10 Thru-Bolts
.250" Dia Thru
2 Holes
4.250" 1.937"
4.375"
Reference Drawing
3
Reference Drawing
2
4 Holes Cleared
for #10 Thru-Bolts
0.625"
B
Four 0.250" Male
Quick Connect
Blade Terminals
2.437"
1.218"
2.812"
.199" Dia Thru
4 Holes
Reference Drawing
1-A
.250" Dia Thru
4 Holes
3.500"
3.938"
.203" Dia Thru
4 Holes
Reference Drawing
1
B
0.812"
3.937"
3.500"
A
B
Ref
.250
4
.250" Dia Thru
2 Holes
.250" Dia Thru
2 Holes
3.437"
3.875"
2.750"
3.875"
4.250" 1.937"
4.375"
5.375"
3.437"
4.250"
3.437"
4.125"
3.875"
1.937"
4.375"
4.250" 1.937"
5.375"
5.750"
5.750"
Reference Drawing
13
Reference Drawing
14
PAGE 4-31
Refe
Reference Drawing
15
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
HPS
HIGH PRESSURE SODIUM
WIRING DIAGRAMS
Wiring Diagram 7
Wiring Diagram 11
Wiring Diagram 2
Wiring Diagram 8
Wiring Diagram 12
Wiring Diagram 3
Wiring Diagram 9
Wiring Diagram 13
Wiring Diagram 4
Wiring Diagram 10
Wiring Diagram 14
HID
CORE & COIL
Wiring Diagram 1
PAGE 4-32
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID CORE & COIL BALLASTS
50 HERTZ
• 50 Hz
• Minimum Starting Temperature: -40° C
• CWA, Normal and High Power factor models available
MH & HPS
50 HZ
Nom Dimensions
Capacitor
Ignitor
UL
Max Open
Total
Max Bench
Input Catalog*
Circuit
Input
Input Circuit
Fuse
Wir Ref Min
Dry Film
Oil Filled
Wt. Catalog Dist. Top
Volts
Number
Type Watts Curr. Volt. Rating Dia Dwg A B µF Volt Dia Ht Oval
Ht (lbs.) Number lamp Rise
(1) 175 WATT M57 METAL HALIDE LAMP
230 M175230AC3M CWA
205 1.00 310
3
15 PC1 2.25 3.55 12 400 6.5 3.82 1.5
3.13 6.7 n/a n/a C
(1) 250 WATT M58 METAL HALIDE LAMP
230 M250230AC3M CWA
282 1.40 285
4
15 PC1 3.0 4.3 18 400 n/a n/a 2.01x3.01 3.1 9 n/a n/a D
(1) 400 WATT M59 METAL HALIDE LAMP
230 M400230AC4M CWA
448 2.20 300
6
15 PC2 2.13 3.75 28 425 n/a n/a 1.91x2.91 3.9 13 n/a n/a D
(1) 1000 WATT M47 METAL HALIDE LAMP
230
M1000230AC5M CWA
1080
4.70 420
13
18 PC3 3.4 5.3 30 440 n/a
n/a 2.01x3.01
3.9
21
n/a
n/a
C
220
8.50
22
A
18 PC3 3.45 4.90 30 440 n/a n/a 1.91x2.91 3.87 24 n/a n/a
M1000230DAC5M CWA 1080
405
B
230
4.80 13
(1) 1500 WATT M48 METAL HALIDE LAMP
220
7.20
20
230 M1500230AC5M CWA
1605
7.29 430
20
18 PC3 4.38 6.18 42(2x21) 480 n/a n/a 1.97x3.66 3.9 30 n/a n/a C
240
6.80
20
(1) 70 WATT S62 HIGH PRESSURE SODIUM LAMP
220
0.95
2
230
S70230LC3M
HX-HPF
88
1.10 120
2
18 PC1 1.9 3.2 10 280
1.26
2.83
n/a
n/a 5.7 HPS150-3A 3
A
240
1.05
2
(1) 250 WATT S50 HIGH PRESSURE SODIUM LAMP
220
1.33
5
230
S250230AC4M
CWA
280
1.24 188
5
18 PC2 1.78 3.58 40 300 n/a
n/a 2.01x3.01
3.9 10.3 HPS400-3A 3
B
240
1.15
5
(1) 400 WATT S51 HIGH PRESSURE SODIUM LAMP (continued)
220
2.00
8
230
S400230AC4M
CWA
465
2.05 190
8
18 PC2 2.5 4.3 64 300 n/a
n/a 1.91x2.91
3.1 15.5 HPS400-3A 3
D
240
2.10
8
(1) 1000 WATT S52 HIGH PRESSURE SODIUM LAMP
220
5.10
15
230
S1000230AC5M
CWA
1100
4.90 445
15
15 PC3 4.0 5.8 36 525 n/a
n/a 1.96x3.65
4.25 27 HPS1000-4B 10
D
240
4.80
15
See page 4-34 for Reference Drawings and
Wiring Diagrams.
HID
CORE & COIL
PAGE 4-33
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
50 HZ
HID CORE & COIL BALLASTS
50 HERTZ
DESCRIPTION
REFERENCE DRAWING PC1
SUFFIX *
For Ballast Only
For Capacitor Only (see pg. 5-5, 5-6)
000
500
0.250 Dia Thru
2 Holes
3.500˝ 3.938˝
4.250˝
3.875˝
4.375˝
5.375˝ 5.750˝
S
M
L
BRef. Dwg.
1
2, 3, 4
PC1
PC2
PC3
A
B
MAX
2.812˝
2.438˝
Bracket
0.250 Dia Thru
8 Holes
0.199 Dia Thru
4 Holes
A
B
MAX
0.250 Dia Thru
2 Holes
W
REFERENCE DRAWING PC3
REFERENCE DRAWING PC2
L
W
M
S
4.00” 0.75” 3.60” 0.25”
5.25” 1.75” 4.60” 0.25”
5.25” 1.25” 4.60” 0.25”
7.75” 1.25” 5.75” 0.25”
7.75” 2.75” 6.10” 0.25”
4 Holes Cleared
for #10 Thru-Bolts
A
B
MAX
4.250˝
2 Holes Cleared
for #10 Thru-Bolts
See p. 5-8 for adjustable mounting brackets and detailed bracket drawings.
3.875˝
4.375˝ 4.750˝
S70230LC3M
70W
High Pressure Sodium
Specification Sheet
Input Volts
WIRING DIAGRAMS
220
230
Regulation
Line Volts
Lamp Watts
Wiring Diagram ±10%
15
Power Factor (min)
Input Watts
NOM. Open Circuit Voltage
Line Current (Amps)
Operating
Open Circuit
Starting
HID
CORE & COIL 50 HERTZ
olts Lamp Dropout Voltage (Line)
on UL Temperature Ratings
Volts
Insulation Class
p Watts Temperature Code
MIN. Starting Temperature
Wiring
ctor (min)
ts CAPACITOR Specifications
Microfarads
en CircuitVolts
Voltage
(min.)
220
240
±5%
±5%
±5%
±5%
±10%
±10%
±10%
90%
88 W
90%
88 W
90%
88 W
90%
88 W
90%
88 W
120 V
120 V
120 V
120 V
120 V
0.60
0.95
0.50
1.10
0.40
1.05
0.37
0.35
0.34
2
2
2
Specification Sheet
Recommended Fuse (Amps)
50Hz HX-HPF
±10%
±5%
135 V 230 135 V
240135 V
0
0
V
V
±10%H (180°C)±10%
±10% H (180°C)
H (180°C)
H (180°C) ±10%
±10%
±10% ±10%
A
- ±10%
-40°F -40°C -40°F -40°C
-40°F
Diagram
17-40°C
90%
90%
90%
1605 W
430 V
ent (Amps)
50Hz Test Procedures
7.20
ating
Secondary Open Ckt Voltage (V)
n Circuit Secondary Current Shorted (A)2.70
6.50
ing
Input Operating Current (A)
Input
Open Circuit Current (A) 20
ended Fuse
(Amps)
1605 W
10 uf
10 uf
280 V
280 V
430 V
1605 W
10 uf
430 V
280 V
7.29 108 - 132 6.80
108 - 132
108 - 132
2.551.15 - 2.15 2.30
1.15 - 2.15
1.15 - 2.15
6.200.46 - 0.56 6.00
0.55 - 0.67
90%
10 uf
430 V
280 V
0.48 - 1.3620 0.50 - 1.43 20
0.53 - 1.50
0.20 - 0.28 0.21 - 0.30 0.23 - 0.42
90%
COM (YEL)
-
-
0 -
0-
7.65 - 9.35 12-14
7.65 - 9.35
9.35
12-14 7.65 -12-14
12-147.65 - 9.35
Cu / Cu
-
7.6512-14
- 9.35
Cu / Cu
-
1
2
COM (YEL)
Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances
A
230 V (BLK)
10 uf
108 - 132
3
STARTER
Wiring Diagram 18
280 V
1.15 - 2.15
LAMP
(RED/BLK)
3
Wiring Diagram
430 V
108 - 132
CAP
(YEL)
Metal Halide
50Hz CWA
1605 W
Input Short Circuit Current (A)
V
150 V
150 V
V
150 V
60Hz Test Procedures
108 - 132
108 - 132
108 - 132
108 - 132
108 - 132
Secondary Open Ckt Voltage (V)
erature Ratings
1.40 - 2.10 1.40 - 2.10 1.40 - 2.10 1.40 - 2.10 1.40 - 2.10
Secondary Current Shorted (A)
H (180°C)
H (180°C)
H (180°C)
H (180°C)
H (180°C)
ation Class
0.04 - 0.13 0.05 - 0.14 0.05 - 0.15
None
C
perature Input
CodeOpen Circuit Current (A)None
0.16 - 0.31 0.16 - 0.31 0.16 - 0.31
Input Short Circuit Current (A)
-22°F -30°C -22°F -30°C -22°F -30°C -22°F -30°C -22°F -30°C
ting Temperature
High Potential
OR Specifications
2000 V
2000 V
2000 V
2000 V
2000 V
Test 1 Minute
2500
2500uf
V
V
uf V
uf V 42.0
uf2500 V 42.0 2500
42.0
42.0 uf 2500 42.0
ofarads Test 1 Second
480 V
480 V
480 V
480 V
480 V
(min.)
Core and Coil Specifications
1.90 in
1.90 in
1.90 in
1.90 in
1.90 in
Dimension A
t Procedures
3.20 in
3.20 in
3.20 in
3.20 in
3.20 in
Dimension B
400 - 4.555.70400
400 - 4.55
- 4.55
- 4.55
ndary Open
Ckt Voltage (V)
lbs 400
5.70 lbs 400 5.70
5.70 lbs
5.70
lbs
lbs - 4.55
Weight
/ Cu
Cu / Cu
Cu / Cu
Coil Material (Pri. / Sec.) 6.55 - 7.99Cu 6.37
- 7.77 6.19 - 7.55
Operating
Current (A)
M48
CAP
(RED)
230V (BLK)
±10%
1.15 - 2.15
0.36 - 0.44
1500W
H±10%
(180°C)
-40°F -40°C -40°F -40°C
1605 W
M1500230AC5M
Wiring Diagram 16
B
MAX
0.234 Dia Thru
4 Holes
CAP
( RED)
LAMP
(RED/BLK)
2.812"
0.250 Dia Thru
2 Holes
2.438"
COM ( YEL)
pout Voltage (Line)
ndary Current
Shorted
(A)
Lead Lengths
(inches)
S62
COM ( YEL)
3.500"
3.938"
Wiring
Diagram
Reference Drawing
Capacitor: R17058517
Height:
B
100 °C MAX
2.83 in
Width / Diameter:
1.26 in 4-34
PAGE
Max Case Temp:
0.250 Dia Thru
2 Holes
0.250 Dia Thru
8 Holes
A
Ignitor: HPS150-3A
Max Case Temp
105 °C
BTL:
3 ft
4.250"
No. 1 (Red or Blue)
No. 2 (Yellow)
No. 3 (Brown)
F-CAN BALLASTS
METAL HALIDE
MH
35-400
• 60 Hz
•M
inimum Starting Temperature: -30° C
•C
WA and High Power Factor Designs
WATT
This ballast may also be used with (1) 70 watt S88
High Pressure Sodium lamp.
7
M98 Designates Venture Lighting catalog numbers
MH70/4/MED, C/4/MED or MS70/C/84/MED/W
22
See page 4-40 for Reference Drawings and
Wiring Diagrams.
This ballast can be used with a MH200 ignitor to operate
(1) 250 watt M103 lamp. Consult Universal for instructions.
8c
23
Two of these ballasts are required to operate the lamp.
Electrical data is for two ballasts, except for “Sound Rating,”
which is for each ballast
* Refer to Page 5-5.
PAGE 4-35
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
CORE & COIL 50 HERTZ
Nom
Dimensions Max
Max Open
Dist Certifications
Input
Catalog
Circuit Input Input Circuit Fuse Wir Overall Case Mtg Total To Sound
Volts
Number
Type Watts Current Voltage Rating Dia Length Length Dim Weight Lamp (ft) Rating UL CSA
(1) 35/39 WATT M130 METAL HALIDE (with built-in ignitor)
120
1120-251A-TC
CWA 55
0.50
225
2
21 9.50
8.35 8.85 3.0
20
B Yes Yes
(1) 50 WATT M110 METAL HALIDE (with built-in ignitor)
120
0.64 3
or 11210-236C-TC HX-HPF 70
240
20 11.75 10.56 11.14 11.0 20 B Yes Yes
277
0.28
2
(1) 70 WATT M85 METAL HALIDE (with built-in ignitor)
120
2.00 6
or 11210-277C-TC7 HX-HPF 98
250
20 11.75 10.56 11.14 11.0 20 B Yes Yes
277
0.90
3
(1) 70 WATT M98 METAL HALIDE (with built-in ignitor)
120
2.00 6
or 11210-506C-TC22 HX-HPF 90
250
20 11.75 10.56 11.14 11.0 20 B Yes Yes
277
0.90
3
120
2.00 6
or 11210-554C-TC HX-HPF 90
250
20 11.75 10.56 11.14 11.0 20 B No Yes
347 0.80 3
(1) 100 WATT M90 METAL HALIDE (with built-in ignitor)
120
2.20 8
or 11210-239C-TC HX-HPF 125
250
20 11.75 10.56 11.14 11.0 20 B Yes Yes
277 1.00 4
120
2.20 8
or 11210-606C-TC HX-HPF 125
250
20 11.75 10.56 11.14 11.0 20 B No Yes
347 0.70 2
(1) 150 WATT M81 METAL HALIDE (with built-in ignitor)
120
3.70 10
or 11210-242C-TC HX-HPF 185
260
20 14.31 13.19 13.75 14.0 20 B Yes Yes
277 1.60 5
(1) 150 WATT M102 METAL HALIDE (with built-in ignitor)
120
3.70 10
or 11210-539C-TC HX-HPF 185
260
20 14.31 13.19 13.75 14.0 20 B Yes Yes
277
1.60
4
(1) 175 WATT M57 METAL HALIDE LAMP
120
2.00
5
or
20 14.32 13.19 13.75 14.0 * B Yes Yes
300
1110-245SC-TC CWA 202
0.85 3
277
120
1.75
5
or
20 11.75 10.55 11.10 14.0 * B Yes Yes
300
1110-564C-TC CWA 205
0.62 2
347
(1) 250 WATT M58 METAL HALIDE LAMP
120
2.50
8
or
20 16.75 15.57 16.13 18.0 * C Yes Yes
280
1110-246C-TC 8c CWA 295
1.10 4
277
120
2.50
8
or
300
22 11.75 10.55 11.10 11.0 * B Yes Yes
1111-246C-TC 23 CWA 300
1.10 4
277
120
2.50
8
or
20 16.65 15.55 16.10 17.5 * C Yes Yes
285
1110-566C-TC CWA 295
0.95 3
347
(1) 400 WATT M59 METAL HALIDE LAMP
120
4.00
10
or
20 19.25 18.06 18.63 22.0 * C Yes Yes
300
1110-247SC-TC CWA 463
1.75 5
277
120
4.00
10
or 1111-247SC-TC 23 CWA 460
300
22 14.31 13.19 13.75 14.0 * B Yes Yes
277 1.75 5
120
4.30
10
or
20 19.25 18.05 18.60 22.0 * C Yes Yes
300
1110-568C-TC CWA 460
1.50 4
347
HPS
35-250
WATT
F-CAN BALLASTS
HIGH PRESSUE SODIUM
• 60 Hz
• Minimum Starting Temperature: -40° C
• CWA and High Power Factor Designs
Nom
Dimensions Max
Max Open
Dist Certifications
Input
Catalog
Circuit Input Input Circuit Fuse Wir Overall Case Mtg Total To Sound
Volts
Number
Type Watts Current Voltage Rating Dia Length Length Dim Weight Lamp (ft) Rating UL CSA
(1) 35 WATT S76 HIGH PRESSURE SODIUM (with built-in starter)
120
0.80
5
or 12210-261C-TC HX-HPF 55
20 11.75 10.55 11.10 9.0 10 B Yes Yes
120
0.35 2
277
(1) 50 WATT S68 HIGH PRESSURE SODIUM (with built-in starter)
120
1.05
3
or 12210-236C-TC HX-HPF 71
20 11.75 10.55 11.10 9.0 10 B Yes Yes
125
0.45 2
277
(1) 70 WATT S62 HIGH PRESSURE SODIUM (with built-in starter)
120
1.60
5
or 12210-237C-TC HX-HPF 97
20 11.75 10.56 11.14 9.15 10 B Yes Yes
140
0.70 2
277
120
1.69
5
or 12210-552C-TC HX-HPF 109
20 11.75 10.55 11.10 9.2 10 B Yes Yes
145
0.63 2
347
(1) 100 WATT S54 HIGH PRESSURE SODIUM (with built-in starter)
120
2.00
5
or 12210-239C-TC HX-HPF 125
20 11.75 10.55 11.10 10.4 10 B Yes Yes
130
0.90 3
277
120
2.10
6
or 12210-606C-TC HX-HPF 126
20 11.75 10.55 11.10 10.4 10 B Yes Yes
165
0.90 3
347
(1) 150 WATT S55 HIGH PRESSURE SODIUM (with built-in starter)
120
2.80
8
or 12210-241C-TC HX-HPF 185
20 14.30 13.15 13.75 14.0 10 B Yes Yes
120
1.20 4
277
120
2.80
8
or 12210-602C-TC HX-HPF 185
20 14.30 13.15 13.75 14.1 10 B Yes Yes
120
1.03 3
347
HID
F-CAN
See page 4-40 for Reference Drawings and
Wiring Diagrams.
PAGE 4-36
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
34
35
White
Line
Insulate Unused Input
Lead for 300 Volts.
B
A
L
L
A
S
T
277V or 347V Black
BALLAST
or 120V
Black/Yellow
Red
Black
White
Wiring Diagram
B
34
A
L
L
A
S
T
F-CAN
0.250" Dia.
1.000"
2.000"
Red
Red
White
4.000"
4.500"
277V
White or
Yellow
Wiring Diagram
34
B
A
L
L
A
S
T
Wiring Diagram
35
Wiring Diagram
36
277V Black
or 120V Black/Yellow
Separately Insulate Unused Input
Lead for 300 Volts
HID CORE & COIL BALLASTS
Line
Insulate Unused Input
Lead for 300 Volts.
White
White or
Yellow
Black
Red
F-CAN
Wiring Diagram
36
Black or
Yellow
0.406"
or 120V
Black/Yellow
0.562"
0.250" Dia.
Separately Insulate Unused Input
1.000"
2.000"
Lead for 300
Volts
Wiring Diagram
35
Wiring
Diagram
Mounting
Bracket Assemblies
4.500"
0.406"
4.000"
36
F-CAN BALLASTS OPTIONAL ACCESSORIES
Mounting Bracket Assemblies
0.562"
Splice Box
Mounting Bracket Assemblies
Tee-Pee Lead
Wire Covers
1.437"
1.500"
2.000"
2.562"
0.250" Dia.
1.750"
0.218" Dia.
1.000"
2.000"
2.531"
1.437"
0.406"
4.000"
4.500"
Tee-Pee Lead Wire Covers
1.500"
2.000"
2.562"
0.562"
Embossed Dimples
2 Places
2.000"
3.000"
1.750"
2.812"
0.850" Dia.
Knockouts
5 Places
0.218" Dia.
Catalog Number
2-BMB-1.
Mounting Bracket Assemblies
Catalog NumberTee-Pee
TP5. Ref.part
Lead#001-2013.
Wire Covers
Available for the remote installation of ballasts. Each
assembly consists of two (2) mounting brackets, four (4)
screws, four (4) washers and four (4) nuts.
For use where ballast is attached to the surface of an
enclosure or raceway.
Embossed Dimples
2 Places
1.437"
1.500"
2.000"
2.562"
2.531"
0.297" Dia.
Mounting Holes
2 Places
Catalog Number SB-4. Splice
Ref. part Box
#001-2009
2.000"
3.000"
2.812"
0.850" Dia.
Knockouts
5 Places
For use with all F-Can Ballasts. It is easily installed on
0.297"F-Can
Dia. ballast. It
the anchor bracket provided on each
Mounting Holes
contains five (5) 7/8” diameter knockouts.
2 Places
Splice Box
1.750"
0.218" Dia.
2.531"
REFERENCE
Tee-Pee DRAWING
Lead Wire Covers
FOR F-CAN
se
Ca
2.000"
3.000"
2.812"
0.850" Dia.
Knockouts
5 Places
0.297" Dia.
Mounting Holes
2 Places
th
ng
Le
Embossed Dimples
2 Places
Height
Width
Splice Box
th
ng
ng
ti
Le
un
l
Mo
al
r
e
Ov
Hole
Mounting
Width
WIRING DIAGRAMS
B
A
Wiring Diagram 20 L
L
A
S
T
Black
L
L
A
S
T
Red
White
White or
Yellow
Wiring Diagram
35
Red
Red
120V Black
277V Black
Wiring Diagram 22
Black or
Yellow
HID
F-CAN
Line
am
B
A
L
L
A
S
T
White
LLAST
B
A
Wiring Diagram
21
Red
or 120V Black/Yellow
Separately
Insulate
Unused Input
Neutral to Lamp
Shell
Lead for 300 Volts
Wiring Diagram
36
Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances
ia.
1.000"
2.000"
00"
0.406"
0.562"
PAGE 4-37
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
IGNITORS
STANDARD IGNITORS • INSTANT RESTRIKE IGNITORS • LONG
DISTANCE IGNITORS • AUTOMATIC SHUTOFF
IGNITORS • SHUTOFF DEVICES
Catalog Number
Description
Reference Drawing Number
--STANDARD IGNITORS (See pg. 5-43)
PULSE START METAL HALIDE
MH 70-3B 13
MH 100-3A
MH 150-1A
MH 200-1B 13
MH 350-1A
P 750-1B13
HPS 1000-4B13
HIGH PRESSURE SODIUM
HPS 150-3A
HPS 400-3A
HPS 450-1B 13
HPS 460-1B 13
HPS 600-1B
HPS 1000-4B 13
HPS 1000-6B 13
For double-ended MH lamps with HX-HPF ballasts: 70 watt (M85), 100 watt (M91), and 150 watt (M81)
29
For MH lamps with HX-HPF ballasts: 35/39w(M130), 50w(M110), 70w(M98), 100w(M90/M140), and 150w(M102/M142) 25
For 150 watt (M102/M142) lamp with CWA ballast
26
For double-ended MH 250 watt (M80) lamp
27a
For MH lamps with CWA ballasts: 175 watt (M152/M137), 200 watt (M136), 250 watt (M153/M138),
320 watt (M154/M132), 350 watt (M131), 400 watt (M155/M135), and 450 watt (M144)
26
For 750 watt (M149) MH lamp
29
For MH lamps: 875 watt (M166) and 1000 watt (M141). It is also used for 1000W HPS lamps
29
For HPS lamps of 150 watt or less with HX-HPF ballast, except 150 watt S56 lamp
26
For HPS lamps from 200 to 400 watts and 150 watt S56 lamp with CWA ballasts
26
For 150 watt S56, 200, 250 or 400 watt lamps with 240 volt/60 Hz reactor ballasts. With attached mounting bracket.
27
For 200, 250 and 400 watt lamps with HX-HPF ballasts and 50 Hz reactor ballasts. With attached mounting bracket.
27
For 600 watt lamps.
27
For 1000 watt HPS and Pulse Start Metal Halide lamps. With attached mounting bracket.
29
Obsolete 29
PLUG REPLACEABLE IGNITORS
PULSE START METAL HALIDE
MH 150-G15
HIGH PRESSURE SODIUM
HPS 150-G01
HPS 400-G05
For MH lamps with HX-HPF ballasts: 35/39 watt (M130), 50 watt (M110), 70 watt (M98), 100 watt (M90/M140),
and 150 watt (M102/M142)
32
For HPS lamps of 150 watt or less with HX-HPF ballast, except 150 watt S56 lamp
For HPS lamps from 200 to 400 watts and 150 watt S56 lamp with CWA ballasts
32
32
INSTANT RESTRIKE IGNITORS
HIGH PRESSURE SODIUM
HPS 150-5B 13
Instant Restrike Ignitor — for lamps of 150 watts or less except 150 watt S56. Ignitor has attached mounting bracket.
30
LONG DISTANCE IGNITORS
PULSE START METAL HALIDE
MH 100-5A
MH 100-5A
MH UNV-5B
HIGH PRESSURE SODIUM
HPS 150-4A
HPS 400-4A
For MH lamps from 35 to 50 watts. Max Ballast to Lamp Distance ( ~ 20’) 25
For MH lamps from 70 to 150 watts. Max Ballast to Lamp Distance ( ~ 30’) 25
For MH lamps from 35 to 450 watts. Ignitor incorporates automatic resetting thermal protection.
Max Ballast to Lamp Distance ( ~ 50’) 33
For HPS lamps of 150 watt or less, excerpt 150 watt S56 lamp. Max Ballast to Lamp Distance ( ~ 20’) 24
For HPS lamps from 200 to 400 watts and 150 watt S56 lamp. Max Ballast to Lamp Distance ( ~ 25’) 33
AUTOMATIC SHUTOFF IGNITORS
PULSE START METAL HALIDE
HID
F-CAN
MH 100-35B 13
MH 150-35B 13
MH 350-15B 13
P 750-15B 13
HIGH PRESSURE SODIUM
HPS 150-45B 13
HPS 400-45B 13
For MH lamps: 35/39 watt (M130), 50 watt (M110), 70 watt (M98), 100 watt (M90/M140), and 150 watt (M102/M142).
With attached mounting bracket
For 150 watt M81 lamp with CWA ballasts. With attached mounting bracket.
For MH lamps: 175 watt (M152/M137), 200 watt (M136), 250 watt (M153/M138), 320 watt (M154/M132),
350 watt (M131), 400 watt (M155/M135), and 450 watt (M144)
For 750 watt (M149) MH lamp
27
31
31
31
For lamps of 150 watts or less except 150 watt S56. With attached mounting bracket.
27
For lamps from 200 to 400 watts and 150 watt S56 with constant wattage autotransformer ballasts. 27
With attached mounting bracket.
AUTOMATIC SHUTOFF DEVICES
In addition to one-piece shutoff ignitors, automatic shutoff devices are available as separate components for use with the ignitors below.
SA-100
13
HPS 150-3A, HPS 150-5B, HPS400-4A, HPS460-1B, MH100-5A, MH70-3B, MH100-3A, MH150-1A
MH350-1A, HPS150-4A, HPS400-3A, HPS600-1B, MHUNV-5B, MH200-1B
33a
May also be available without attached mounting bracket. Substitute “A” suffix for “B” suffix when ordering. Minimum quantities may apply.
PAGE 4-38
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
IGNITORS
Lamp ANSI
Circuit
Watts Code Type
Standard
Ignitors
Auto
Shutoff
Instant
Restrike
Long Distance
Ignitors
Lamp
ANSI
Circuit
Standard
Watts Code Type Ignitors
HPS 150-45B
HPS 150-45B
HPS 150-45B
HPS 150-45B
HPS 150-45B
HPS 400-45B
HPS 400-45B
HPS 400-45B
HPS 400-45B
HPS 400-45B
HPS 400-45B
HPS 400-45B
—
—
HPS 150-5B
HPS 150-5B
HPS 150-5B
HPS 150-5B
HPS 150-5B
—
—
—
—
—
—
—
—
—
HPS 150-4A
HPS 150-4A
HPS 150-4A
HPS 150-4A
HPS 150-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
HPS 400-4A
—
—
35
50
70
70
100
100
100
150
150
150
350
S76
S68
S62
S54
S55
S56
S50
S50
S50
S51
S51
S51
S106
S52
Reactor
Reactor, HX
Reactor, HX
Reactor, HX
Reactor, HX
CWA
Reactor
CWA
HX
Reactor
CWA
HX
CWA
CWA
Long Distance
Ignitors
—
—
MH 70-35B
MH 100-35B
MH 100-35B
MH 100-35B
—
—
MH 150-35B
MH 100-35B
MH 100-5A
MH 100-5A
MH 100-5A
MH 100-5A
MH 100-5A
MH 100-5A
—
—
—
MH 100-5A
METAL HALIDE IGNITORS
HIGH PRESSURE SODIUM IGNITORS
35
50
70
100
150
150
250
250
250
400
400
400
600
1000
Auto
Shutoff
HPS 150-3A
HPS 150-3A
HPS 150-3A
HPS 150-3A
HPS 150-3A
HPS 400-3A
HPS 450-1B
HPS 400-3A
HPS 460-1B
HPS 450-1B
HPS 400-3A
HPS 460-1B
HPS 600-1B
HPS 1000-4B
350
M130
M110
M85
M98
M90
M90
M91
M81
M81
M102
M131
M131
Reactor
HX
HX
HX
Reactor
CWA
HX
HX
CWA
HX
Reactor
HX
MH 100-3A
MH 100-3A
MH 70-3B
MH 100-3A
MH 100-3A
MH 100-3A
MH 70-3B
MH 70-3B
MH 150-35B
MH 100-3A
MH 70-3B
MH 70-3B
—
—
—
—
STANDARD IGNITORS
LONG DISTANCE IGNITORS
Standard Ignitors are supplied with all Universal High
Pressure Sodium and Metal Halide ballasts requiring ignitors.
These ballasts are supplied with an appropriate external ignitor
unless the ignitor is permanently attached to or built into the
ballast.
Long Distance Ignitors are used in situations where a ignitor
must be mounted further from the lamp than is recommended
for a standard ignitor. The maximum lamp to ignitor distance for
these ignitors is 50 feet, which may vary depending on the type
of lamp, ballast, fixture, and wiring.
INSTANT RESTRIKE IGNITORS
AUTOMATIC SHUTOFF IGNITORS
An Instant Restrike Ignitor generates multiple pulses to restrike
a lamp arc after a brief power interruption has extinguished
it, without the typical 3-minute cool-down time. A Standard
Ignitor cannot restrike an arc until the lamp has had time to
sufficiently cool. Even though an Instant Restrike Ignitor can
reinitiate the lamp arc immediately upon restoration of power,
the lamp is still subject to warmup. The following chart is based
on an S55 lamp.
In the event of a lamp failure, a Standard Ignitor will continue
to pulse, trying to start the lamp. This may reduce the life of the
ignitor. An Automatic Shutoff Ignitor will apply pulses for 10 to
12 minutes and then deactivate if a lamp arc cannot be
initiated. Resetting the ignitor is accomplished by momentarily
interrupting the power to the ballast. For this reason, these ignitors are not recommended for use on unswitched circuits.
Restrike
Time
1 second
5 seconds
15 seconds
30 seconds
1 minute
Cold Start
2 seconds
Instant
Instant
Instant
Instant
Instant
Light Output
On Reignition
87%
83%
76%
62%
46%
36%
AUTOMATIC SHUTOFF DEVICES
Lamp Warmup
Time
Automatic shutoff devices can be used with a standard ignitor
to convert standard ignitor into an automatic shutoff ignitor.
Simply use the automatic shutoff device with appropriate
standard ingnitor. Matching ignitors are listed in the table on
previous page. Automatic shutoff device coupled with standard
ignitor is equivalent to automatic shutoff ignitor. Wiring diagrams of SA-100 automatic shutoff device are shown on Ref.
Drawings 34a and 34b.
35 seconds
70 seconds
130 seconds
190 seconds
255 seconds
360 seconds
PLUG REPACEABLE IGNITORS
Incorporates terminals and a separate mounting base to
simplify construction and replacement.
TEMPERATURE RATING
Most ignitors are rated for a 105°C maximum case
temperature. Consult ballast specification sheets at
www.unvlt.com for specific details.
PAGE 4-39
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID
IGNITORS
Time Lamp Is
Extinguished
REFERENCE DRAWINGS
IGNITORS
All dimensions in decimals.
All lead lengths: 13 inches ±1
No. 1 (Red or Blue)
No. 1 (Red or Blue)
120V (Black/Yellow)
No. 1 (Red or Blue)
No. 2 (Yellow)
No. 2 (Yellow)
No. 2 (Yellow)
No. 2 (Yellow)
No. 3 (Brown)
No. 3 (Brown)
COM (Yellow)
No. 3 (Brown)
1.25"
2.00"
1.25"
2.50"
2.50"
Ref. Drawing 25
Ref. Drawing 24
1.25"
1.25"
2.25"
Ref. Drawing 25a
Ref. Drawing 26
120V (Black/Yellow)
No. 1 (Red or Blue)
Com. (Yellow)
No. 2 (Yellow)
Ballast (Blue/White)
No. 3 (Brown)
Lamp (Blue)
Mounting Bracket
Mounting Bracket
1.31"
1.31"
No. 1 (Red or Blue)
No. 1 (Red or Blue)
No. 2 (Yellow)
No. 2 (Yellow)
No. 3 (Brown)
No. 3 (Brown)
Mounting Bracket
Mounting Bracket
1.31"
1.31"
1.25"
1.25"
0.22"
3.50"
4.31"
4.75"
0.22"
Com. (Yellow)
Com. (Yellow)
Ballast (Blue/White)
Ballast (Blue/White)
Lamp (Blue)
Lamp (Blue)
Mounting Bracket
Mounting Bracket
1.56"
1.62"
0.88"
0.88"
3.50"
4.31"
4.75"
0.22"
Ref. Drawing 28
Ref. Drawing 27a
Ref. Drawing 27
2.05"
2.05"
0.88"
0.88"
3.50"
4.31"
4.75"
1.25"
1.25"
2.05"
2.05"
3.10"
4.31"
4.75"
0.22"
Ref. Drawing 29
1.56"
1.50"
2.60"
2.65"
0.88"
0.88"
3.50"
4.31"
4.75"
0.22"
Ref. Drawing 31
Ref. Drawing 32
HID
IGNITORS
Ref. Drawing 30
0.22"
3.75"
4.31"
4.75"
Note: Nominal dimensions provided above
Contact Universal for drawings and/or tolerances
PAGE 4-40
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Notes
HID
PAGE 4-41
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
eHID
Less energy. Enhanced performances.
Experience significant energy savings and increased lumen output vs. halogen lamps with Electronic
High Intensity Discharge (HID) ballasts from Universal Lighting Technologies. Vossloh-Schwabe (VS), also
a Panasonic Lighting Company, recently merged its US operation into Universal. This merger combines
Vossloh’s market leading high quality electronic HID product line with Universal’s extensive offering.
There are numerous advantages of using VS electronic HID ballasts. Operating HID lamps used in HID
lighting systems with electronic ballasts greatly increases system efficiency in comparison with magnetic
ballasts. These ballasts are designed to provide optimal lamp performance
and maximum energy savings. With enhanced capabilities to downsize
the form factor of luminaire housings and reduce wiring costs, VS electronic HID ballasts lead the way to electronic solutions for HID lighting. Microprocessor controlled intelligence offers superior lamp performance and the
flexibility for proprietary value-added functions. VS electronic HID ballasts
cover your HID needs with products for Metal Halide Lamps ranging from
20 Watts to 150 Watts.
VS electronic HID ballasts continuously monitors lamp characteristics
during operation and adjusts the lamp current to optimize performance.
This guarantees controlled operation in all modes of operation. The lamp
color temperature is also stabilized by using VS electronic HID ballasts
due to its relatively constant output power characteristics in addition to
producing flicker free lighting that usually occurs at the end of the discharge lamp’s service life. The
technology enhancements of VS electronic HID ballasts, allowing very small form factors and light weight
designs, has enabled new, innovative luminaire designs.
ELECTRONIC HID
Universal Lighting Technologies is a member of the Panasonic Group
Product Overview
Micro Series: The introduction of the smallest eHID ballasts in the market was
coordinated with the launch of the new miniaturized capsule MH lamps
enabling the ultimate luminaire design flexibility. Extremely compact
and aesthetically pleasing, luminaire designs are approaching
the form factor and size of low voltage halogen systems.
Mini Ballast Series: Two ideal form factors that are used
in millions of HID track light luminaires characterize the mini series
of eHID ballasts. The mini-slim and mini-square units revolutionized
track lighting by allowing significantly smaller and greater
variety of luminaire designs while providing
energy savings of 60-70%
versus halogen systems.
ELECTRONIC HID
Standard Case “Valued-added Series”: Millions of recessed,
track-head and specialty luminaires have used the de facto industry
standard enclosure since introduction. The significant energy savings
and enhanced reliability of our ballasts promoted the rapid escalation
of electronically ballasted MH luminaires for almost 15 years. Technological advancements have now allowed the integration of multiple,
value-added functions such as: a powersource for the self-heating
thermal protectors, an electronic 277V step-down transformer, and
an intelligent auxiliary lighting control for back-up lighting during
lamp hot restrike modes. Ideal for new, retrofit and replacement
applications in recessed luminaires.
Features and Benefits:
• Optimum lamp performance
• Rugged, compact and lightweight design
• High power factor
• Enhanced color and CRI uniformity
• Shut-down protection
• Reduced wiring costs
• Eliminates nuisance lamp cycling at end-of-lamp life (intelligent lamp sensing capabilities)
• Constant lamp power
• Reduced lamp dropouts due to improved line voltage dip withstand
• Quiet operation
• Durable performance for various applications
• Fewer SKUs required in inventory
• Broadens design flexibility for new applications and luminaries
PAGE 5-2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
eHID Product Family
Part #
Description
Lamp Wattage
Lamp Type
Input Voltage
Input Power
Mounting
Lead Exit
Dimensions
Wiring
Micro Series
188514
M2012CK-7EUN
20
M/C156
120
24.5
No Feet
Side
1
1
188882
M2012CK-7EUN-F
20
M/C156
120
24.5
Feet
Side
2
1
188883
M2012CK-7EUN-J
20
M/C156
120
24.5
Studs
Top
3
1
188574
M2212CK-7EUN
22
M/C175
120
26.5
No Feet
Side
1
1
188884
M2212CK-7EUN-F
22
M/C175
120
26.5
Feet
Side
2
1
188885
M2212CK-7EUN-J
22
M/C175
120
26.5
Studs
Top
3
1
188635
M3912CK-7EUN
39
M/C130
120
45
No Feet
Side
4
1
188776
M3912CK-7EUN-F
39
M/C130
120
45
Feet
Side
2
1
188756
M3912CK-7EUN-J
39
M/C130
120
45
Studs
Top
3
1
188757
MTm3912CK-7EUN
39Tm
M/C179
120
45
No Feet
Side
4
1
188777
MTm3912CK-7EUN-F
39Tm
M/C179
120
45
Feet
Side
2
1
188758
MTm3912CK-7EUN-J
39Tm
M/C179
120
45
Studs
Top
3
1
Mini-Slim Series
188246
M3912CK-6EUN-F
39
M/C130
120
45
Feet
Side
5
1
188164
M7012CK-6EUN-F
70
M/C98, M/C139, M/C143
120
77
Feet
Side
5
1
1
Mini-Square Series
188901
M2012-27CK-6EU-F
20
M/C156
120-277
24
Feet
Side
10
188902
M2012-27CK-6EU-J
20
M/C156
120-277
24
Studs
Top
9
1
1889031
M2012/27CK-6EU-JT3
20
M/C156
120/277
24/26
Studs
Top
9
2a,2b,2c
188895
M3912-27CK-6EU-F
39
M/C130
120-277
44
Feet
Side
10
1
188896
M3912-27CK-6EU-J
39
M/C130
120-277
44
Studs
Top
9
1
1888971
M3912/27CK-6EU-JT3
39
M/C130
120/277
44/46
Studs
Top
9
2a,2b,2c
188939
M7012-27CK-6EU-F
70
M/C98, M/C139, M/C143
120-277
77
Feet
Side
10
1
188940
M7012-27CK-6EU-J
70
M/C98, M/C139, M/C143
120-277
77
Studs
Top
9
1
1889411
M7012/27CK-6EU-JT3
70
M/C98, M/C139, M/C143
120/277
77/79
Studs
Top
9
2a,2b,2c
Standard Series
188610
M2012-27CK-5EU-F
20
M/C156
120-277
24
Feet
Side
12
1
1886111
M2012/27CK-5EU-JT3
20
M/C156
120/277
24/26
Studs
Top
13
2a, 2b, 2c
188156
M3912-27CK-5EU
39
M/C130
120-277
44
No Feet
Side
14
1
188157
M3912-27CK-5EU-F
39
M/C130
120-277
44
Feet
Side
12
1
188301
M3912-27CK-5EU-J
39
M/C130
120-277
44
Studs
Top
13
1
1886291
M3912/27CK-5EU-JT3
39
M/C130
120/277
44/46
Studs
Top
13
2a, 2b, 2c
1886302
M3912/27CK-5EU-JA3
39
M/C130
120/277
46/187
Studs
Top
13
3a, 3b, 3c
188612
M5012-27CK-5EU-F
50
M148 or M110
120-277
56
Feet
Side
12
1
1886131
M5012/27CK-5EU-JT3
50
M148 or M110
120/277
56/58
Studs
Top
13
2a, 2b, 2c
188165
M7012-27CK-5EU
70
M/C98, M/C139, M/C143
120-277
78
No Feet
Side
14
1
188166
M7012-27CK-5EU-F
70
M/C98, M/C139, M/C143
120-277
78
Feet
Side
12
1
188167
M7012-27CK-5EU-J
70
M/C98, M/C139, M/C143
120-277
78
Studs
Top
13
1
1886311
M7012/27CK-5EU-JT3
70
M/C98, M/C139, M/C143
120/277
79/81
Studs
Top
13
2a, 2b, 2c
1886321
M7012/27CK-5EU-JA3
70
M/C98, M/C139, M/C143
120/277
81/212
Studs
Top
13
3a, 3b, 3c
1886331
M10012/27CK-5EU-JT3
100
M/C90, M/C140 and M/C164
120/277
110/212
Studs
Top
13
2a, 2b, 2c
188168
M10012-27CK-5EU
100
M/C90, M/C140 and M/C164
120-277
110
No Feet
Side
14
1
188169
M10012-27CK-5EU-F
100
M/C90, M/C140 and M/C164
120-277
110
Feet
Side
12
1
188302
M10012-27CK-5EU-J
100
M/C90, M/C140 and M/C164
120-277
110
Studs
Top
13
1
1886341
M10012/27CK-5EU-JA3
100
M/C90, M/C140 and M/C164
120/277
112/235
Studs
Top
13
3a, 3b, 3c
188638.053
M15012-27CK-5EU-F
150
M/C102/E and M/C142/E
120-277
163
Feet
Side
16
1
188639.053
M15012-27CK-5EU-J
150
M/C102/E and M/C142/E
120-277
163
Studs
Top
15
1
M15012/27CK-5EU-JT3
150
M/C102 and M/C142
120/277
163/165
Studs
Top
15
2a, 2b, 2c
188989.051,3
Footnotes:
1 – “JT3” models have 120V power source for operating the heater on self-heating thermal protectors allowing dual-rated input voltage fixtures.
3 – Exceeds EISA 2007 90% minimum ballast efficiency requirement for 150W and higher HID lamp applications.
PAGE 5-3
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
ELECTRONIC HID
2 – “JA3” models have same 120V power source as JT3 models , but also have an integrated auxiliary light control which drives a quartz restrike back-up lamp.
Wiring Diagrams
1
N
WHITE
120V
RED
L
1
BLACK
BLUE
GREEN
120/277V with IDTP Tap
2b
WIRING (with 3-wire 120V IDTP)
WIRING (with 4-wire 120V IDTP)
RP-1B
IDTP 2
black
L
blue
N
WHITE
black
120/277
white
120/277
N
WHITE
PURPLE
blue
white
L
RP-5A
IDTP 2
red
2a
PURPLE
BLACK
BLACK
GREEN
GREEN
RED
RED
1
BLUE
1
BLUE
2c
WIRING (with 3-wire 277V IDTP)
RP-4A
IDTP 2
L
277
N
red
white
black
WHITE
PURPLE
BLACK
GREEN
RED
1
BLUE
120/277V with Auxiliary Control + IDTP Tap
Wiring & Dimensions Diagrams (shown in millimeters and inches)
3b
WIRING (with 3-wire 120V IDTP)
WIRING (with 4-wire 120V IDTP)
RP-1B
IDTP 2
N
WHITE
HALOGEN LAMP
<150W
L
blue
white
black
120/277
black
120/277
N
ORANGE
PURPLE
WHITE
BLACK
GREEN
GREEN
RED
RED
1
Connect red lead to center contact on Edison base lampholders
2
IDTP - Insulation Detector Thermal Protector
1
BLUE
Notes for Wiring Diagram
1
blue
ORANGE
PURPLE
BLACK
BLUE
ELECTRONIC HID
HALOGEN LAMP
<150W
red
L
RP-5A
IDTP 2
white
3a
3c
WIRING (with 3-wire 277V IDTP)
RP-4A
IDTP 2
L
black
277
N
WHITE
HALOGEN LAMP
<150W
red
white
ORANGE
PURPLE
BLACK
GREEN
RED
1
BLUE
PAGE 5-4
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Wiring
Dimming Ballasts
4a
4b
WIRING (For Fixed Output)
WIRING (For Dimming Control)
RED
RED
BLUE
BLUE
GREEN
GREEN
BLACK
BLACK
WHITE
WHITE
GREY (+)
GREY (+)
PURPLE (+)
PURPLE (+)
0 - 10VDC
DIMMER
Dimensions
1
2
33.5/1.32
29.7/1.17
33.0/1.30
97.7/3.85
76.0/2.99
Temp. Testpoint
31.0/1.22
28.0/1.10
Temp. Testpoint
104.7/4.12
3
4
33.5/1.32
16.7/0.66
33.5/1.35
96.7/3.81
90.7/3.57
Temp. Testpoint
38.1/1.5
Temp. Testpoint
11.8/0.47
8-32 stud
50.8/2.0
PAGE 5-5
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
ELECTRONIC HID
30.1/1.19
Dimensions
5
6
28.6/ 44.2/
1.13 1.74
28.6/ 44.2/
1.13 1.74
133/5.25
133/5.25
140..0/5.51
140.0/5.51
30.0/1.18
30.0/1.18
7
8
44.2/
1.74
64.8/2.55
75.6/2.98
22.1/
0.87
127.8/5.03
50.8/2
86.8/3.42
10.9/0.43
95.1/3.74
39.5/
1.56
Temp. Testpoint
9
30.6/1.21
10
76.2/3.0
64.8/2.55
75.6/2.98
38.1/1.5
86.8/3.42
89.4/3.52
95.1/3.74
50.8/2.0
11.8/0.47
8-32 stud
30.6/1.21
30.6/1.21
ELECTRONIC HID
11
12
64.8/2.55
72.1/
2.84
76.0/2.99
92.0/
3.62
46.0/
1.31
86.8/3.42
133.5/5.26
95.1/3.74
140.0/5.51
39.9/1.57
31.8/1.25
PAGE 5-6
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Dimensions
13
14
92.0/3.62
92.0/
3.62
46.0/1.31
127.5/5.02
8-32 stud
133.5/5.26
50.8/2.0
11.4/0.45
39.9/1.57
39.9/1.57
15
16
92.0/3.62
72.1/
2.84
92.0/
3.62
46.0/
1.31
46.0/1.31
127.5/5.02
8-32 stud
133.5/5.26
50.8/2.0
140.0/5.51
11.4/0.45
39.9/1.57
39.9/1.57
17
72.0/
2.84
92.0/
3.62
46.0/
1.31
202.0/ 7.95
208.0/ 8.19
60.0/2.36
ELECTRONIC HID
PAGE 5-7
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
General:
If the electrical current through an HID lamp is properly stabilized, an HID plasma arc with very high luminous efficiency is created
in the arc tube chamber resulting in a very efficient light source. The internal pressure of the arc tube chamber rises as the arc tube
temperature increases and will attain between 1 and 10 bar; thereby, defining these lamps as high-pressure HID lamps, high intensity discharge lamps or simply HID lamps. The light output and color rendition of HID lamps vary considerably depending on the lamp
family (mercury, metal halide or sodium lamps).
HID lamps can only be started and operated with ballasts. Ignitors or ignition voltage characteristics are additionally required for
sodium and metal halide lamps. As well as stabilizing the lamp’s operating point, ballasts also influence the lamp’s output and luminous flux, the system light output, the service life of the lamps as well as the color temperature of the light source.
Electromagnetic or electronic ballasts can be used for HID lamps, but unlike fluorescent lamps, lamp
efficiency is not significantly improved by the use of electronic ballasts. However, electronic ballasts can
lead to a reduction of the inherent losses and thus to an increase in system efficiency. In addition,
electronic ballasts can ensure gentle lamp operation, which may increase lamp’s service life.
Electronic Ballasts for Metal Halide Lamps
Electronic ballasts are designed with all the components required to operate metal halide lamps, including ignition, power factor
correction, and stable normal operation. Furthermore, they safely shutdown lamps at the end of their service life to prevent high
temperatures from being generated in the luminaires that could influence the service life of the luminaire or its components.
Universal Lighting Technologies also provides special electronic ballasts for additional luminaire functions such as heater power for
insulation detection thermal protectors and for switching on of an auxiliary incandescent lamp for the dark phase of an HID lamp
during initial warm-up or during hot-restrike cool-down mode.
Standards/Regulations
ANSI C82.14
Low-Frequency Square Wave Electronic Ballasts for Metal Halide Lamps
UL 1598
Standard for Safety-Luminaires
ANSI C82.77
Harmonic Emission Limits-Related Power Quality Requirements
or Lighting Equipment
ANSI/UL 1029
Standard for Safety-High Intensity HID Lamp Ballasts
ANSI/IEEE C62.41
Surge Voltages in Low Voltage AC Power Circuits
ELECTRONIC HID
US Code of Federal Regulations Title 47 –Telecommunications Part 18– Industrial, Scientific and Medical Devices
PAGE 5-8
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
Technical Specifications:
Operating voltage range
120VAC rated: 120V 277V ±10%
277VAC rated: 277V ±10%
120–277V rated: 108V–305V
120/277V rated: 108V–132V and 249V–305V
Leakage current
≤0.5mA
Hot restrike auxiliary lamp operation
In order to ensure continuous illumination even during the ignition period or in the event of a lamp drop-out due to short term power
outage, an additional incandescent lamp (maximum 150W) can be used on models designated with a JA suffix.
Short circuit issues
The ballast output metal halide lamp leads are basically short-circuit-proof. However, any shorts or connections between those lamp
leads to the ballast case or to safetyneutral (earth ground) will destroy the ballasts. Likewise the metal halide lamp leads
shall not be connected to input power connections nor shall the auxiliary lamp leadsbe shorted together otherwise the ballast’s
circuitry could be damaged or fail.
Provisions in the luminaire design should be implemented to prevent all lead wires but especially lamp leads from being pinched,
damaged, or cut during luminaire assembly, field installation or normal service.
Mechanical Mounting:
Surface
Firm, flat, preferably metal surface required to ensure good heat transfer for long ballast service life and reliability. Avoid mounting on
uneven or protruding surfaces.
Mounting Location
Electronic ballasts must be protected against moisture and heat. Outdoor applications must utilize luminaires with the appropriate
weatherproof ratings depending on location. Most Universal Lighting Technologies electronic ballasts are rated “Outdoor Type 1”.
Fastening
Use mechanical means to ensure ballasts are fixed tightly to flat surfaces. Use appropriately sized screws depending on the
ballast mounting slot size or spring clips to provide interference fit.
If ballast is destined for installation in a luminaire, sufficient heat transfer must be ensured between the electronic ballast and the
luminaire housing. Electronic ballasts should be mounted with the greatest possible clearance from heat sources or lamps.
During operation, the temperature measured at the ballast’s tc point must not exceed the specified maximum value.
PAGE 5-9
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
ELECTRONIC HID
Heat transfer
Application And Operating Information
Technical Specifications:
• Dimensional tolerances:
– Case: ±1mm (±0.039”)
– Standard lead length tolerances: +50mm (+2”) or –30mm (–1”) Micro lead length tolerances: ±15mm (±0.6”)
– Slot width on “F” mounting tabs: 5mm (0.20”); for Mini-Square Size: 4mm (0.157”)
• Remote wiring guidelines:
– Each lamp’s lead wires must be run in a separate conduit from the input power leads to achieve good EMI performance and
maximum remote capabilities. Lamp leads shall not be bundled together, but each set of lamp leads shall be run in its own conduit.
– Individual lamp lead wires must be used for external fixture wire extensions using wire types SF-2 (equivalent to SEW-2 or
3071) or SFF-2 (equivalent to SEWF-2 or 3070) or alternately, if approved by ULT, high voltage luminaire wire with a 18AWG
conductor and a 1000VAC minimum voltage rating. Temperature rating is especially critical if the lamp lead extension wires
are directly connected to lampholder terminals.
– Maximum remote distances:
See individual model specification sheets.
The specified maximum remote distances are based on lamp leads run in a minimum ½” internal diameter
conduit, pipe or flexible conduit. For longer remote distances contact the TES group at Universal Lighting.
– Using service power cords (types SJ, SO, ST, SV etc.) or metal clad cable assemblies for lamp lead extension wire are not
recommended as they are not compatible with the above characteristics, can cause starting problems and shall not be used
unless ULT gives written approval.
Insulation clearance
ELECTRONIC HID
Remote mounted ballasts shall be installed per National Electrical Code and local codes while also complying with wiring
methods per Universal Lighting Technologies recommendations. Per UL requirements, thermal insulation shall be a minimum
of 3” from any ballast surface.
PAGE 5-10
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
Safety Functions:
Regulatory approvals
Universal Lighting Technologies electronic HID ballasts are UL listed or UL recognized component and cUL listed for use in Canada.
Shutdown of defective lamps
In the event of a lamp failing to ignite or of a lamp with low or high operating voltages (end of lamp’s service life), the electronic
ballast will switch off after a defined period of time (typically 30 minutes). The ballast will also shut-down if the lamp fails to achieve
symmetrical current operation (rectification) or if lamp leads are shorted to each other. After lamp replacement, the ballast output can
be reset by disconnecting (count to 10) and then reconnecting input power.
Transient input voltage
Electronic ballasts incorporate transient protection that complies with ANSI C62.41 and ANSI C82.14 test procedure and values.
Temperature Protection
To prevent excess temperatures, ballasts contain thermal protection devices or thermal sensing circuitry. A ballast will restart after it
has cooled down, however, it might be necessary to briefly reset the input power after the over-temperature condition is resolved.
General guidelines
Always disconnect power to the luminaire before installation or service of the ballasts. Install to all provisions of local or National
Electric Codes. The ballast case/green lead must be grounded. Dispose of any replaced ballasts or lamps properly per local
environmental regulations.
Reliability and Service Life:
The electronic ballast service life is inversely proportional to the temperature of its critical internal components. Normal ballast
operation shall have the temperature of the tc point less than the warranted values in the individual specification sheets
Electrical Installation:
3-Phase connection of luminaires with electronic ballasts
Power factor compensation
Luminaires with electronic ballasts do not need power factor compensation, as the typical power factor range of electronic
ballasts is 95 to 99%.
PAGE 5-11
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
ELECTRONIC HID
Prior to operating newly installed lighting systems, please check the ballast’s rated voltage range to ensure it is appropriate
for the job site input power supply voltage. The neutral power supply wire must be connected securely to all luminaires and to
all ballasts. Power supply conductors must only be connected or disconnected when the circuit is not energized. The neutral
conductor must never be disconnected as the first disconnected wire nor individually at the circuit panel, at a distribution wiring
junction box or at the luminaire during energized power supply operation as out-of balance voltage operation can lead to serious
over-voltages and subsequent ballast failures.
Application And Operating Information
Wiring
Wiring between the power supply, electronic ballasts and lamp must comply with the respective circuit diagram.
Note: the ballast (metal) case (using toothed washer) or provided green lead must be connected to safety-neutral (earth ground).
In addition, all metal luminaire parts and metal lamp reflector/housings shall also be connected to earth ground for safety and for
proper lamp starting. Metal halide luminaires must only be fitted with electrical components that are rated to withstand ignition voltages of 4kV. To ensure compliance with RFI suppression limits, input and output conductors should not be run in the same conduit as
lamp conductors. Conduit size recommendations are stated in the individual ballast specification sheets or
construction notes.
Lamp maintenance notice
To replace end-of-service lamps, turn-off luminaire power, remove and replace lamps then turn-on luminaire power. If power was not
turned off during lamp replacement, the luminaire/ballast-input power must be reset to restart the new lamp. If the lamp or wiring is
defective, the ballast will “shut-down” in 1.5 to 30 minutes depending upon the fault condition.
Supplemental IDTP wiring
The IDTP (insulation detector thermal protector) is required by UL for most recessed luminaires. This fast acting thermal
protector is typically mounted on the same junction box as the electronic ballast. Special “JT” electronic ballasts provide a
separate 120V power supply for the IDTP heater to allow the luminaire to be rated for both 120V and 277V operation. See the
individual ballast specifications for the proper wiring procedures for JT & JA ballasts with this IDTP heater function.
Note: When using JT or JA ballasts on multiple lamp luminaires, only one ballast yellow or purple lead should be connected to the
IDTP heater. All other ballasts’ yellow or purple leads should be capped-off. Operation of JT and JA ballasts on 208V and 240V is not
recommended, as the IDTP may not function properly.
Lamp compatibility
Not all HID lamps are compatible with all electronic ballasts. Therefore, consult with Universal Lighting Technologies Technical
Support or a specific lamp company regarding a certain lamp’s compatibility.
External fuse ratings
ELECTRONIC HID
All Universal Lighting Technologies electronic HID ballasts have internal fuses for EOL protection; however, if external fuses
are specified, use a 3A slow blow fuse for 20W-100W ballasts and a 5A slow blow fuse for 150W & 210W ballasts.
PAGE 5-12
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Notes
ELECTRONIC HID
PAGE 5-13
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Vossloh Schwabe, a subsidiary of the
Panasonic group, has been manufacturing
and providing lampholders of the highest
quality and reliability to the European and
US markets since 1920. With products
available to meet all your lamp, ballast,
and fixture requirements, these lampholders
will deliver peace of mind for years to come.
LAMPHOLDERS
Universal Lighting Technologies is a member of the Panasonic Group
Application And Operating Information
Mounting Styles:
With the different fixture designs and applications in the market there are a number of lampholder mounting configurations
available to meet all applications. These mounting styles, while demonstrated and geared towards linear fluorescent lamps,
are also applicable to compact fluorescent lampholders as well.
Push Through:
The push through lampholder is the most common
in the United States. This lampholder is inserted into
a rectangular cut-out in the fixture and snaps into
place with ballast wires being inserted into the base
from underneath.
Snap-In:
Snap-In lampholders are available in two styles.
The first is very similar application wise to the push
through style with the difference being that it is
pushed into the fixture from the top instead of the
bottom. These lampholders wire from the bottom
of the fixture as well. The second variant snaps in
from the top as well but uses pin holes instead of a
rectangular cutout. This allows the customer to use
that actual fixture to mount the lampholder instead
of a dedicated socket bar. Wiring this type of
lampholders is done either through the bottom or
laterally through the sides of the lampholder.
LAMPHOLDERS
Butt On:
These lampholders are designed to mount directly
to the sides of the fixture and are available with
two mounting options. One has through holes for
M3 screws, the second has pins either laterally or
vertically across the back of the lampholder that
snap into two pre-drilled holes in the fixture housing.
Both models are available with spring mounts and
two different thicknesses (9mm and 13.5mm).
Contact egress is available from the side or bottom
of the lampholder.
PAGE 6-2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
Slide On:
These lampholders simply slide onto the end of
a fixture into a knocked out channel. All version
of this lampholder wire from the bottom.
Slides into existing channel
at the end of the fixture
Rotor Styles:
Integrated Rotor:
Our integrated rotor system is a single piece construction that is simple and easy to use with no
moving parts and an easy lamp insertion force.
Moving Rotor:
Moving rotor systems have a separate piece in the center of the lampholder that rotates with the
lamp to aid in locking it in place. Two different systems are available; the Big Rotor system and
our Roto-Clic system which has an audible click when the lamp is fully seated in the lampholder.
Shunting:
Non-Shunted lampholder have two individual contacts inside, one contact for each pin of the lamp.
Each contact has its own separate wire terminal on either side of the lampholder. This type of
lampholder is used with programmed or rapid start ballasts.
Shunted lampholders have one continuous contact running through the lampholder that electrically
connects both pins of the lamp together. These lampholders will only have push in contacts on one
side of the lampholder and are used with instant-start ballasts.
Lamp Axis:
Lamp axis is the distance from the surface of the
fixture to the center of the lamp. For T8 and T12
lamps, these are commonly referred to as low
profile for T8 only (16mm), standard (23mm),
and tall (31mm) and can vary by a couple mm
from manufacturer to manufacturer.
ELECTRONIC HID
PAGE 6-3
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Application And Operating Information
Lamp Stop:
Lamp stop or “nib” as it is sometime called is a small pin the
extends up from the front of some push through lampholders.
This can be used to assist in locating the lampholder in the
fixture or to help provide a slight inward rake to the lampholder.
Lampholder Springs:
Butt-On style lampholders can be purchased with or without a
spring. These are small metal clips on the rear of the lampholder
that help to provide compression on the lamp. They can be used
on either side of the fixture or both as required by the manufacturer.
Circle I:
This stems from a UL requirement for instant start systems to contain either a type CC rated ballast or a “Circle I” rated lampholder.
At this time, all of our shunted or instant start lampholders meet this requirement and are marked accordingly with the I mark.
Nomenclature:
Our lampholders carry both a type number and a reference number. The type number is more like a family number where the
numeric character signify similarities and differences as you progress through the five digit number. For example, the 291xx series
are all 23mm, push-through, lampholders for T8/T12 lamps. As you move further into these numbers it signifies other identifiers
like shunting and stopping pins. The reference number is the orderable number that is used to order the exact product.
Packaging:
Standard packing through ULT is in full bag quantities. For linear fluorescent lampholders this is commonly 1,000 piece, for compact
fluorescent 500, and for HID, Halogen, and eHID this ranges from 10-250 pieces. Packing quantities vary by model and are listed on
all spec sheets.
ELECTRONIC HID
A select number of our lampholders are available in smaller “distributor friendly” packages, please consult your ULT sales
representative for more information.
PAGE 6-4
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Snap-In Lampholders
T8 & T12
Snap-In Lampholders
Reference Number
Lamps
Lamp Axis (mm)
Shunted
Push-In Terminals
Recommended Cut-Out (mm)
Drawing
Weight
Unit Pcs.
23370
539128
T8
18
-
Lateral
ø5.5 x 23
1
5.3
1000
23372
539140
T8
18
Shunted Right
Lateral
ø5.5 x 23
1
5.3
1000
23374
539141
T8
18
Shunted Left
Lateral
ø5.5 x 23
1
5.3
1000
24350
537153
T8/T12
23.5
-
Base
ø5.5 x 23
2
5.7
1000
24352
536320
T8/T12
23.5
Shunted
Base
ø5.5 x 23
2
5.7
1000
23350
537157
T8/T12
23.5
-
Lateral
ø5.5 x 23
1
5.8
1000
23352
536293
T8/T12
23.5
Shunted Right
Lateral
ø5.5 x 23
1
5.8
1000
23354
536294
T8/T12
23.5
Shunted Left
Lateral
ø5.5 x 23
1
5.8
1000
24360
537155
T8/T12
30
-
Base
ø5.5 x 23
2
5.9
1000
24362
536322
T8/T12
30
Shunted
Base
ø5.5 x 23
2
5.9
1000
23360
537160
T8/T12
30
-
Lateral
ø5.5 x 23
1
6
1000
23362
536284
T8/T12
30
Shunted Right
Lateral
ø5.5 x 23
1
6
1000
23364
537160
T8/T12
30
Shunted Left
Lateral
ø5.5 x 23
1
6
1000
24150
537144
T8
18
-
Lateral
13.3 x 25.5
3
5.4
1000
21452
536309
T8
18
Shunted Right
Lateral
13.3 x 25.5
3
5.4
1000
24154
536310
T8
18
Shunted Left
Lateral
13.3 x 25.5
3
5.4
1000
24140
537141
T8
18
-
Lateral
10 x 20
5
6
1000
24142
536306
T8
18
Shunted Right
Lateral
10 x 20
5
6
1000
24144
536307
T8
18
Shunted Left
Lateral
10 x 20
5
6
1000
24170
537150
T8/T12
21
-
Lateral
13.3 x 25.5
3
5.6
1000
24172
536315
T8/T12
21
Shunted Right
Lateral
13.3 x 25.5
3
5.6
1000
24174
536316
T8/T12
21
Shunted Left
Lateral
13.3 x 25.5
3
5.6
1000
24160
537147
T8/T12
21
-
Lateral
10 x 20
5
6
1000
24162
536312
T8/T12
21
Shunted Right
Lateral
10 x 20
5
6
1000
24164
536313
T8/T12
21
Shunted Left
Lateral
10 x 20
5
6
1000
24100
537132
T8/T12
25
-
Lateral
13.3 x 25.5
3
9
1000
24102
536297
T8/T12
25
Shunted Right
Lateral
13.3 x 25.5
3
9
1000
24104
536298
T8/T12
25
Shunted Left
Lateral
13.3 x 25.5
3
9
1000
24110
537165
T8/T12
25
-
Lateral
13.3 x 25.5
4
9
1000
24112
536300
T8/T12
25
Shunted Right
Lateral
13.3 x 25.5
4
9
1000
24114
536301
T8/T12
25
Shunted Left
Lateral
13.3 x 25.5
4
9
1000
24120
537138
T8/T12
25
-
Lateral
10 x 20
5
5.7
1000
24122
536303
T8/T12
25
Shunted Right
Lateral
10 x 20
5
5.7
1000
24124
536304
T8/T12
25
Shunted Left
Lateral
10 x 20
5
5.7
1000
* Consult www.UNVLT.com for complete lampholder offering and complete specs.
1
3
2
4
PAGE 6-5
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
LAMPHOLDERS
Type
Push-Through, Slide-On Lampholders
T8 & T12
Push-Through Lampholders
Type
Reference Number
Lamps
Lamp Axis (mm)
Shunted
Lamp Stop
Recommended Cut-Out (mm)
Drawing
Weight (g)
29300
509134
T8
16
-
W/ Stop
9 x 25.5
6
4.7
Unit Pcs.
1000
29300
509136
T8
16
Shunted
W/ Stop
9 x 25.5
6
4.7
1000
29301
509135
T8
16
-
-
9 x 25.5
6
4.5
1000
29301
509137
T8
16
Shunted
-
9 x 25.5
6
4.5
1000
29100
545845
T8/T12
23
-
W/Stop
9 x 25.5
7
6.8
1000
29101
545849
T8/T12
23
-
-
9 x 25.5
7
6.8
1000
29125
545840
T8/T12
23
Shunted
W/Stop
9 x 25.5
7
6.8
1000
29126
545842
T8/T12
23
Shunted
-
9 x 25.5
7
6.8
1000
28700
109342
T8/T12
31
-
W/ Stop
9 x 25.5
9
7.8
1000
28725
109376
T8/T12
31
Shunted
W/ Stop
9 x 25.5
9
7.8
1000
28701
109343
T8/T12
31
-
-
9 x 25.5
9
7.8
1000
28726
109377
T8/T12
31
Shunted
-
9 x 25.5
9
7.8
1000
* Consult www.UNVLT.com for complete lampholder offering and complete specs.
Slide-On Lampholders
Type
Reference Number
Lamps
Lamp Axis (mm)
Shunted
Lamp Stop
Recommended Cut-Out (mm)
Drawing
Weight (g)
Unit Pcs.
29150
545858
T8/T12
23
-
0.5 - 0.8
9.15 x 26.2
10
6.8
1000
29155
545862
T8/T12
23
Shunted
0.5 - 0.8
10
6.8
1000
LAMPHOLDERS
* Consult www.UNVLT.com for complete lampholder offering and complete specs.
6
9
7
10
PAGE 6-6
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Butt-On Lampholders
T8 & T12
Butt-On Lampholders
Type
Reference Number
Lamps
Lampholder
Thickness
49505
537174
T8/T12
9.5
-
-
ø4.2 x 26
11
5
1000
49525
536337
T8/T12
9.5
Shunted
-
ø4.2 x 26
11
5
1000
49506
537175
T8/T12
9.5
-
X
ø4.2 x 26
12
5.5
1000
49526
536338
T8/T12
9.5
Shunted
X
ø4.2 x 26
12
5.5
1000
59505
537206
T8/T12
9.5
-
-
ø4.2 x 26
13
4.8
1000
59525
536369
T8/T12
9.5
Shunted Right
-
ø4.2 x 26
13
4.8
1000
59545
536373
T8/T12
9.5
Shunted Left
-
ø4.2 x 26
13
4.8
1000
59506
537207
T8/T12
9.5
-
X
ø4.2 x 26
14
4.8
1000
59526
536370
T8/T12
9.5
Shunted Right
X
ø4.2 x 26
14
4.8
1000
59546
536347
T8/T12
9.5
Shunted Left
X
ø4.2 x 26
14
4.8
1000
49105
537166
T8/T12
13
-
-
ø4.2 x 26
11
5.1
1000
49125
536329
T8/T12
13
Shunted
-
ø4.2 x 26
11
5.2
1000
49106
537167
T8/T12
13
-
X
ø4.2 x 26
12
5.9
1000
49126
536330
T8/T12
13
Shunted
X
ø4.2 x 26
12
5
1000
59105
537182
T8/T12
13
-
-
ø4.2 x 26
13
5
1000
59125
536325
T8/T12
13
Shunted Right
-
ø4.2 x 26
13
5
1000
59145
536349
T8/T12
13
Shunted Left
-
ø4.2 x 26
13
5
1000
59106
537183
T8/T12
13
-
X
ø4.2 x 26
14
5
1000
59126
536346
T8/T12
13
Shunted Right
X
ø4.2 x 26
14
5
1000
59146
536350
T8/T12
13
Shunted Left
X
ø4.2 x 26
14
5
1000
49500
537173
T8/T12
9.5
-
-
Holes 25mm O.C.
15
5
1000
49520
536336
T8/T12
9.5
Shunted
-
Holes 25mm O.C.
15
5
1000
47502
101740
T8/T12
9.5
-
X
Holes 25mm O.C.
16
5.5
1000
59500
537205
T8/T12
9.5
-
-
Holes 25mm O.C.
17
4.7
1000
59520
536368
T8/T12
9.5
Shunted Right
-
Holes 25mm O.C.
17
4.7
1000
59541
536372
T8/T12
9.5
Shunted Left
-
Holes 25mm O.C.
17
4.7
1000
49100
537165
T8/T12
13
-
-
Holes 25mm O.C.
15
5
1000
49120
536328
T8/T12
13
Shunted
-
Holes 25mm O.C.
15
5
1000
47102
404681
T8/T12
13
-
X
Holes 25mm O.C.
16
6
1000
59100
537181
T8/T12
13
-
-
Holes 25mm O.C.
17
5
1000
59420
536344
T8/T12
13
Shunted Right
-
Holes 25mm O.C.
17
5
1000
59140
536348
T8/T12
13
Shunted Left
-
Holes 25mm O.C.
17
5
1000
Shunted
Spring
Adjustment
Recommended Cut-Out (mm)
Drawing
Weight
Unit Pcs.
11
13
12
14
PAGE 6-7
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
LAMPHOLDERS
* Consult www.UNVLT.com for complete lampholder offering and complete specs.
Butt-On Lampholders
T8 & T12
15
17
LAMPHOLDERS
16
PAGE 6-8
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Push-Through, Snap-In, Butt-On Lampholders
T5
Push-Through Lampholders
Type
Reference Number
Lamps
Lamp Axis
Lamp Stop
Recommended Cut-Out (mm)
Drawing
Weight
Unit Pcs.
09420
505737
T5/T5HO
15
X
9.7 x 19.5
1
3.4
1000
09421
505739
T5/T5HO
15
-
9.7 x 19.5
1
3.3
1000
09432
545933
T5/T5HO
20
X
9.7 x 19.5
2
3.6
1000
09433
545935
T5/T5HO
20
-
9.7 x 19.5
2
3.6
1000
09434
545937
T5/T5HO
25
X
9.7 x 19.5
3
3.9
1000
09435
545939
T5/T5HO
25
-
9.7 x 19.5
3
3.9
1000
09426
505745
T5/T5HO
35
X
9.7 x 19.5
4
4.5
1000
09427
505746
T5/T5HO
35
-
9.7 x 19.5
4
4.5
1000
09105
100305
T5/T5HO
13.2
Screw Fixing
9.7 x 19.5
5
3.2
1000
Lamp Stop
* Consult www.UNVLT.com for complete lampholder offering and complete specs.
Snap-In Lampholders
Type
Reference Number
Lamps
Lamp Axis
Recommended Cut-Out (mm)
Drawing
Weight
Unit Pcs.
09440
505747
T5/T5HO
14
9.7 x 19.5
6
3.3
1000
09446
545894
T5/T5HO
18
9.7 x 19.5
7
3.5
1000
09447
545896
T5/T5HO
23
9.7 x 19.5
8
3.8
1000
09450
505750
T5/T5HO
15
ø3.7 x 13.2
9
3.4
1000
09460
505751
T5/T5HO
11.8
ø3.2 x 19.5
10
3.1
1000
09465
508314
T5/T5HO
11.8
ø3.2 x 19.5
11
3.1
1000
ø3.2 x 18
* Consult www.UNVLT.com for complete lampholder offering and complete specs.
Butt-On Lampholders
Type
Reference Number
Lamps
Lampholder
Thickness
Spring
Adjustment
09404
505732
T5/T5HO
9.3
-
09405
505733
T5/T5HO
9.3
-
09406
505734
T5/T5HO
9.3
09407
508590
T5/T5HO
09415
505735
09416
09205
Recommended Cut-Out (mm)
Drawing
Weight
Unit Pcs.
13
2.8
1000
ø3.8 x 20
14
2.9
1000
X
ø3.8 x 20
14
3.3
1000
12.5
-
ø3.8 x 20
15
3
1000
T5/T5HO
9.3
-
ø3.8 x 10
16
2.9
1000
505736
T5/T5HO
9.3
X
ø3.2 x 10
16
3.2
1000
100310
T5/T5HO
9.3
-
ø3.2 x 10
17
2.5
1000
1
3
2
4
PAGE 6-9
LAMPHOLDERS
* Consult www.UNVLT.com for complete lampholder offering and complete specs.
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Butt-On Lampholders
T5
11
5
13
6
14
7
LAMPHOLDERS
15
16
8
9
17
10
PAGE 6-10
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
GU6.5, G8.5, GX8.5, GY9.5, GX10, G(X)12,
K12S-7, PGJ5, RX7s Lampholders
Type
Reference
Number
Lamp
Type
Material
Mounting
34515
534218
GU6.5
Ceramic
34516
534219
GU6.5
34525
538634
GU6.5
HID
Lead
Length
Lead Material
Drawing
Weight
Unit Pcs.
#4 Screw Holes 15mm OC
305mm
PTFE
1
20
100
Ceramic
Threaded #4 Holes 15mm OC
305mm
PTFE
1
20
100
Ceramic
#4 Screw Holes 15mm OC
200mm
PTFE
2
15
100
GU6.5
G8.5
33650
526018
G8.5
Ceramic
#4 Screw Holes 15mm OC
Terminals
N/A
3
12.6
150
33600
502394
G8.5
Ceramic
#4 Screw Holes 15mm OC
Terminals
N/A
3
5
1000
34650
547807
GX8.5
LCP
#4 Screw Holes 23mm OC
Terminals
N/A
4
11.9
50
34651
547808
GX8.5
LCP
#4 Screw Holes 23mm OC
Terminals
N/A
4
12.6
50
37002
534105
GY9.5
Ceramic
#4 Screw Holes 30mm O.C.
305mm
SF-2
5
62
25
100
GX8.5
GY9.5
GX10
31550
543963
GX10
Steatitie
#4 Screw Holes 18mm OC
200mm
7
21.7
31550
543153
GX10
Steatitie
#4 Screw Holes 18mm OC
305mm
7
25
100
31400
509356
GX10
PPS
#4 Screw Holes 18mm OC
Terminals
8
9.2
100
31402
537049
GX10
PPS
#4 Screw Holes 18mm OC
240mm
8
33.9
100
31402
534636
GX10
PPS
#4 Screw Holes 18mm OC
460mm
8
33.9
100
31402
534050
GX10
PPS
#4 Screw Holes 18mm OC
765mm
8
33.9
100
31402
536822
GX10
PPS
#4 Screw Holes 18mm OC
915mm
8
33.9
100
25
N/A
G(X)12
31921
526251
G12
Ceramic
#8 Screw Holes 30mm OC
765mm
PTFE
9
72
31921
529773
G12
Ceramic
#8 Screw Holes 30mm OC
1170mm
PTFE
9
88
25
31936
108257
G12
Ceramic
#8 Screw Holes 30mm OC
460mm
SF-2
10
56
25
31936
525750
G12
Ceramic
#8 Screw Holes 30mm OC
765mm
SF-2
10
72
25
31936
526211
G12
Ceramic
#8 Screw Holes 30mm OC
1524mm
SF-2
10
144
25
42000
509213
G12
LCP
#8 Screw Holes 30mm OC
N/A
N/A
11
20
25
41900
507656
GX12
Ceramic
#8 Screw Holes 30mm OC
300mm
SI
12
58.5
25
21100
107652
K12s-7
Ceramic
N/A - Socket Only
Terminals
N/A
13
25
25
21100
107677
K12s-7
Ceramic
#10 Screw Holes 61.4mm OC
Terminals
N/A
13
70
25
K12s-7
34155
538630
PGJ5
Ceramic
#4 Screw Holes 11.6mm OC
460mm
PTFE - Lat
14
21.7
100
34116
534102
PGJ5
Ceramic
#4 Screw Holes 11.6mm OC
305mm
PTFE - Cent
15
11.5
100
34116
537057
PGJ5
Ceramic
#4 Screw Holes 11.6mm OC
460mm
PTFE - Cent
15
18.6
100
34116
537784
PGJ5
Ceramic
#4 Screw Holes 11.6mm OC
765mm
PTFE - Cent
15
27.8
100
34125
537454
PGJ5
Ceramic
#4 Screw Holes 11.6mm OC
200mm
PTFE - Lat
16
10.5
100
34125
535782
PGJ5
Ceramic
#4 Screw Holes 11.6mm OC
305mm
PTFE - Lat
16
12.5
100
34125
542304
PGJ5
Ceramic
#4 Screw Holes 11.6mm OC
460mm
PTFE - Lat
16
14.5
100
30608
108913
RX7s
Ceramic
#8 Screw Holes 34mm OC
460mm
PTFE
17
72
25
30611
100732
RX7s
Ceramic
#8 Screw Holes 34mm OC
305mm
SF-2
17
68
25
31662
107065
RX7s
PPT
#8 Screw Holes 34mm OC
300mm
SI
18
23
25
32301
506216
RX7s
Ceramic
Captive mounting for #8 Screw
360mm
SF-2
19
34
300
32330
100928
RX7s
Ceramic
Central tapped hole for #8 Screw
300mm
SI
19
75
200
RX7s
PAGE 6-11
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
LAMPHOLDERS
PGJ5
E26, E39 Lampholders
HID
Type
Reference
Number
Lamp
Type
Material
Mounting
Lead
Length
Lead Material
Drawing
Weight
Unit Pcs.
62609
109459
E26
Porcelain
#8 Screw Holes 18mm OC
62610
525523
E26
Terminals
N/A
20
64
200
Porcelain
Bushings for #8 Screw 18mm OC
Terminals
N/A
20
64
62030
102597
200
E26
Porcelain
#8 Screw Holes 18mm OC
Terminals
N/A
21
61
64707
200
504262
E26
PET - White
ST #7 Screws 18mm OC
Terminals
N/A
22
15.4
64707
500
506381
E26
PET - Black
ST #7 Screws 18mm OC
Terminals
N/A
22
15.4
500
E26
E39
12870
109014
E39
Porcelain
Bushings 35mm OC
Terminals
N/A
23
190
50
12876
109518
E39 w/grip
Porcelain
Bushings 35mm OC
Terminals
N/A
23
190
50
12850
108851
E39
Porcelain
#10 Screw Holes 30mm OC
Terminals
N/A
24
208
50
12851
109272
E39 w/grip
Porcelain
#10 Screw Holes 30mm OC
Terminals
N/A
24
208
50
12860
108869
E39
Porcelain
Bracket for #10 Screws 56.5mm OC
Terminals
N/A
25
219
50
12861
109460
E39 w/grip
Porcelain
Bracket for #10 Screws 56.5mm OC
Terminals
N/A
25
219
50
12862
108870
E39 w/grip
Porcelain
Bracket for #10 ST Screws 56.5mm OC
Terminals
N/A
26
227
50
12650
501981
E39
PPS
#10 Screw Holes 30mm OC
Terminals
N/A
27
109
50
12660
501982
E39
PPS
Bracket for #10 Screws 56.5mm OC
Terminals
N/A
28
119
50
LAMPHOLDERS
1
2
3
4
5
6
PAGE 6-12
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID Lampholders
7
HID
13
8
14
9
15
10
LAMPHOLDERS
16
11
17
12
PAGE 6-13
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
HID Lampholders
HID
18
23
24
19
25
20
LAMPHOLDERS
26
21
27
22
28
PAGE 6-14
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
B15d, G(Z)4 G(X)5.3 G(Y)6.35,
G(Z)4, G9, G53, GU4 Lampholders
Type
Reference
Number
Lamp Type
Material
Mounting
48101
108925
B(A)15d
Steel/Ceramic
48102
102927
B(A)15d
78103
102929
B(A)15d
HALOGEN
Lead
Length
Lead Material
Drawing
Weight
Unit Pcs.
#4 Screw Holes 25.5mm OC
Terminals
w/ground
1
16
500
Steel/Ceramic
#4 Screw Holes 25.5mm OC
Terminals
N/A
2
17
500
Steel/Ceramic
#4 Screw Holes 25.5mm OC
Terminals
w/ground
2
18
500
B15d
G(Z)4 G(X)5.3 G(Y)6.35
32400
109855
G4/G5.3/G6.35
Ceramic
#4 Screw Holes 11.5mm OC
152mm
PTFE
3
8.1
1000
32400
536857
G4/G5.3/G6.35
Ceramic
#4 Screw Holes 11.5mm OC
200mm
PTFE
3
8.3
1000
32400
109856
G4/G5.3/G6.35
Ceramic
#4 Screw Holes 11.5mm OC
300mm
PTFE
3
8.5
1000
32400
525681
G4/G5.3/G6.35
Ceramic
#4 Screw Holes 11.5mm OC
665mm
PTFE
3
8.8
1000
32400
100946
G4/G5.3/G6.35
Ceramic
#4 Screw Holes 11.5mm OC
750mm
PTFE
3
9
1000
32480
504542
G4/G5.3/G6.35
Ceramic
#4 Screw Holes 11.5mm OC
300mm
PTFE
4
8.8
1000
32700
109851
G4/G5.3/G6.35
Ceramic
#4 Screw Holes 11.4mm OC
155mm
PTFE
5
12.8
1000
32700
109852
G4/G5.3/G6.35
Ceramic
#4 Screw Holes 11.4mm OC
305mm
PTFE
5
12.8
1000
32700
109853
G4/G5.3/G6.35
Ceramic
#4 Screw Holes 11.4mm OC
590mm
PTFE
5
12.8
500
32720
525857
G4/G5.3/G6.35
Ceramic
#4 Screw Holes 26mm OC
320mm
PTFE
6
8.7
1000
32720
529699
G4/G5.3/G6.35
Ceramic
#4 Screw Holes 26mm OC
960mm
PTFE
6
8.7
1000
G(Z)4
30449
530250
G(Z)4
PPS
#4 Screw Holes 20mm OC
140mm
PTFE
7
3.8
1000
60464
108892
G(Z)4
PPS
N/A
Terminals
N/A
9
2.2
1000
60469
108893
G(Z)4
PPS
N/A
Terminals
N/A
10
1.9
1000
32500
101035
G(Z)4
PPS
#4 Screw Holes 12mm OC
140mm
PTFE
11
8.7
500
32500
509069
G(Z)4
PPS
#4 Screw Holes 12mm OC
195mm
PTFE
11
8.9
500
32500
509035
G(Z)4
PPS
#4 Screw Holes 12mm OC
765mm
PTFE
11
9.8
500
33710
508306
G9
LCP
20.8x2 Ext, #3 Holes 14mm OC
Terminals
N/A
12
6
1000
33711
520728
G9
LCP
20.8x2 Ext, #4 Holes 23mm OC
Terminals
N/A
13
8.7
1000
33721
508610
G9
Ceramic
20.8x2 Ext, #4 Holes 23mm OC
Terminals
N/A
13
10.6
1000
1000
G9
508611
G9
Ceramic
20.8x2 Ext, #4 Holes 23mm OC
Terminals
N/A
13
10.2
509357
G9
Ceramic/LCP
N/A
Terminals
N/A
14
7.5
1000
33900
534132
G9
Ceramic
N/A
140mm
PTFE
15
14.2
1000
33500
502004
G9
Ceramic
#4 Screw Holes 17mm OC
Terminals
N/A
16
16
1000
140mm
PTFE
17
3.8
1000
G53
33100
107694
G53
PPS
#8 Screw Holes
GU4
32400
109855
GU4
Ceramic
#4 Screw Holes 11.5mm OC
152mm
PTFE
18
8.1
1000
32400
109856
GU4
Ceramic
#4 Screw Holes 11.5mm OC
300mm
PTFE
18
8.1
1000
32400
525681
GU4
Ceramic
#4 Screw Holes 11.5mm OC
665mm
PTFE
18
8.1
1000
32400
536857
GU4
Ceramic
#4 Screw Holes 11.5mm OC
200mm
PTFE
18
8.1
1000
32412
538286
GU4
Ceramic
460mm
PTFE
18
8.1
1000
32480
504542
GU4
Ceramic
#4 Screw Holes 11.5mm OC
300mm
PTFE
19
8.8
1000
32700
109851
GU4
Ceramic
#4 Screw Holes 11.4mm OC
155mm
PTFE
20
12.8
1000
32700
109852
GU4
Ceramic
#4 Screw Holes 11.4mm OC
305mm
PTFE
20
12.8
1000
32700
109853
GU4
Ceramic
#4 Screw Holes 11.4mm OC
590mm
PTFE
20
12.8
1000
32720
525857
GU4
Ceramic
#4 Screw Holes 26mm OC
320mm
PTFE
21
8.7
1000
32720
529699
GU4
Ceramic
#4 Screw Holes 26mm OC
960mm
PTFE
21
8.7
1000
PAGE 6-15
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
LAMPHOLDERS
33721
33800
GU5.3, GU10/GZ10, R7s Lampholders
HALOGEN
Type
Reference
Number
Lamp Type
Material
Mounting
Lead
Length
Lead Material
Drawing
Weight
Unit Pcs.
32480
106457
GU5.3
Ceramic
#4 Screw Holes 11.5mm OC
32480
504542
GU5.3
140mm
PTFE
22
8.8
1000
Ceramic
#4 Screw Holes 11.5mm OC
300mm
PTFE
22
9.1
32680
101248
1000
GU5.3
Ceramic
#4 Screw Holes 12mm OC
140mm
PTFE
23
11
32690
500
536856
GU5.3
Ceramic
#4 Screw Holes 12mm OC
140mm
PTFE
23
12
500
33300
109547
GU5.3
LCP
#4 Screw Holes 11.5mm OC
Terminals
N/A
24
2.2
1000
32400
109855
GU5.3
Ceramic
#4 Screw Holes 11.5mm OC
140mm
PTFE
25
8.1
1000
Terminals
N/A
26
7
1000
GU5.3
GU10/GZ10
31000
108979
GU10/GZ10
LCP
#4 Screw Holes 18mm OC
R7s
30543
109450
R7s
Al
#4 Screw Holes 28mm OC
350mm
PTFE
27
16.7
1000
30550
100720
R7s
Al
#4 Screw Holes 28mm OC
350mm
PTFE
27
16.7
1000
1000
30541
108756
R7s
Al
#4 Screw Holes 28mm OC
320mm
PTFE
27
16.5
32300
100912
R7s
Ceramic
#8 Screw Holes 65mm OC
200mm
PTFE
28
25
400
32310
400036
R7s
Ceramic
#8 Screw Holes 65mm OC
350mm
PTFE
29
72
200
32310
107195
R7s
Ceramic
#8 Screw Holes 65mm OC
200mm
PTFE
29
72
200
32320
400080
R7s
Ceramic
#8 Screw Holes 65mm OC
114mm
PTFE
30
77
200
1
4
5
LAMPHOLDERS
2
6
3
7
PAGE 6-16
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Halogen Lampholders
9
HALOGEN
14
10
15
11
16
12
17
LAMPHOLDERS
13
18
19
PAGE 6-17
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Halogen Lampholders
HALOGEN
20
26
21
22
27
23
28
LAMPHOLDERS
24
29
25
30
PAGE 6-18
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
2G7, 2GX7, 2G8, 2G10, 2G11, G(X)24,
G(X)24 Rotary Lock Lampholders
Type
Reference
Number
Lamp Type
Material
Mounting
35613
500574
2G7
PBT
35610
109235
2G7
35611
109238
35612
109240
CFL
Lead
Orientation
Misc
Drawing
Weight
Unit Pcs.
10 x 20 Snap-In
Horizontal
-
1
18
500
PBT
10 x 20 Snap-In / #4 Screw Holes
Horizontal
-
2
15
500
2G7
PBT
#8 Screw Holes 24mm OC
Horizontal
-
3
17
500
2G7
PBT
#4 Screw Holes for Rear Mount
Horizontal
-
4
14
500
2G7
2GX7
35613
500575
2GX7
PBT
10 x 20 Snap-In
Horizontal
-
1
17
500
35620
109237
2GX7
PBT
10 x 20 Snap-In / #4 Screw Holes
Horizontal
-
2
15
500
35621
109239
2GX7
PBT
#8 Screw Holes 24mm OC
Horizontal
-
3
17
500
35622
109241
2GX7
PBT
#4 Screw Holes for Rear Mount
Horizontal
-
4
14
500
59000
526755
2G8
PBT
#4 Screw Holes
-
-
5
19.6
250
Horizontal
-
6
25.5
250
2G8
2G10
36300
101521
2G10
PBT
#4 Screw Holes 24mm OC
2G11
36051
101489
2G11
PBT
Lateral Pivot Brackets
Horizontal
-
7
14
500
36051
532687
2G11
PBT
Lateral Pivot Brackets
Horizontal
Shunted
7
14
500
500
36050
101485
2G11
PBT
Lateral #8 Screw Holes 24mm OC
Horizontal
-
8
14
36050
532685
2G11
PBT
Lateral #8 Screw Holes 24mm OC
Horizontal
Shunted
8
14
500
36052
101491
2G11
PBT
13.3 x 25.5 Snap-In
Vertical
-
9
14
500
36052
532689
2G11
PBT
13.3 x 25.5 Snap-In
Vertical
Shunted
9
14
500
36053
101493
2G11
PBT
13.3 x 25.5 Snap-In
Horizontal
-
10
14
500
36053
532691
2G11
PBT
13.3 x 25.5 Snap-In
Horizontal
Shunted
10
14
500
G(X)24
71211
527560
G(X)24q-1
PBT
4X #4 Screw Holes 20.6mm OC
Vertical
10/13W
11
12.9
500
71212
527561
G(X)24q-2
PBT
4X #4 Screw Holes 20.6mm OC
Vertical
18W
11
12.9
500
71219
527566
G(X)24q-3/4
PBT
4X #4 Screw Holes 20.6mm OC
Vertical
26/32/42W
11
12.9
500
71215
527564
G(X)24q-5
PBT
4X #4 Screw Holes 20.6mm OC
Vertical
57W
11
13.5
500
500
527565
G(X)24q-6
PBT
4X #4 Screw Holes 20.6mm OC
Vertical
70W
11
13.5
528120
G(X)24q-1
PBT
4.5mm W Split pins spaced 34.5mm
Vertical
10/13W
12
11.9
500
72112
528121
G(X)24q-2
PBT
4.5mm W Split pins spaced 34.5mm
Vertical
18W
12
11.9
500
72119
528126
G(X)24q-3/4
PBT
4.5mm W Split pins spaced 34.5mm
Vertical
26/32/42W
12
11.9
500
72115
528124
G(X)24q-5
PBT
4.5mm W Split pins spaced 34.5mm
Vertical
57W
12
12.5
500
500
72116
528125
G(X)24q-6
PBT
4.5mm W Split pins spaced 34.5mm
Vertical
70W
12
12.5
71311
527589
G(X)24q-1
PBT
10x20 snap-in Foot
Horizontal
10/13W
13
12
500
71312
527590
G(X)24q-2
PBT
10x20 snap-in Foot
Horizontal
18W
13
12
500
71319
527596
G(X)24q-3/4
PBT
10x20 snap-in Foot
Horizontal
26/32/42W
13
12
500
71315
527594
G(X)24q-5
PBT
10x20 snap-in Foot
Horizontal
57W
13
12.6
500
500
71316
527595
G(X)24q-6
PBT
10x20 snap-in Foot
Horizontal
70W
13
12.6
71711
527794
G(X)24q-1
PBT
#8 Screw Holes 24mm OC
Horizontal
10/13W
14
15.2
500
71712
527795
G(X)24q-2
PBT
#8 Screw Holes 24mm OC
Horizontal
18W
14
15.2
500
71719
527800
G(X)24q-3/4
PBT
#8 Screw Holes 24mm OC
Horizontal
26/32/42W
14
15.2
500
71715
527798
G(X)24q-5
PBT
#8 Screw Holes 24mm OC
Horizontal
57W
14
15.8
500
71716
527799
G(X)24q-6
PBT
#8 Screw Holes 24mm OC
Horizontal
70W
14
15.8
500
G(X)24 Rotary Lock
45940
507993
G(X)24q-2
PBT
#4 Screw Holes 28.8mm OC
Vertical
18W
15
20.2
500
45960
507994
G(X)24q-3
PBT
#4 Screw Holes 28.8mm OC
Vertical
26/32W
15
20.2
500
45930
507992
G(X)24q-3/4
PBT
#4 Screw Holes 28.8mm OC
Vertical
26/32/42W
15
20.2
500
45980
507995
G(X)24q-4
PBT
#4 Screw Holes 28.8mm OC
Vertical
42W
15
20.2
500
PAGE 6-19
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
LAMPHOLDERS
71216
72111
CFL Lampholders
CFL
1
6
2
7
3
LAMPHOLDERS
8
4
9
5
PAGE 6-20
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
CFL Lampholders
10
CFL
13
14
11
12
15
LAMPHOLDERS
PAGE 6-21
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Sign Illuminating
Ballasts
A Complete Range Of Solutions…
From The Name You Trust
Universal Lighting Technologies (“Universal”) is known throughout the sign
business as a company that can set and meet today’s toughest industry
standards. Our high-output ballasts are great for rugged outdoor sign
cabinet applications because they provide ultra-reliable, low-temperature
starting as low as -20° F. All Universal sign ballasts offer Class P thermal
protection.
• Signa® Electronic Sign ballasts are ideal for new sign
installations with minimum wire connections, universal input
voltage, parallel lamp operation, and maximum energy savings.
• Signa® Electronic Sign ballasts, when paired with our wiring
blocks, offer the perfect solution for magnetic to electronic sign
cabinet retrofits.
Universal offers the convenience of one-stop shopping for not just sign
ballasts, but compact fluorescent, linear fluorescent, HID, and all your other
ballast needs.
For the unmistakable sign of quality and reliability, turn to Universal.
Universal Lighting Technologies is a member of the Panasonic Group
Plastic Sign Ballasts
Universal ® sign ballasts provide ultra-reliable low-temperature starting —
plus Class P thermal protection.
Application And Operating Information
Heat
Light Output vs. Temperature
Ballasts generate heat during normal operation. By design,
fluorescent ballasts should operate so that their maximum
hot-spot case temperature does not exceed 80°C (176°F).
Operating at higher temperatures will shorten ballast life
or may cause the thermal protection cicuit to trip.
The temperature the ballast reaches depends on the temperature of the area surrounding it — plus the heat-conducting
surface touching the ballast. Ballasts should be installed in a
manner that avoids future overheating. To maintain normal
ballast temperature, you should:
The light output of a fluorescent lamp varies according to the mercury vapor pressure inside the lamp. This pressure is controlled by
the coldest spot on the bulb wall. The ballast may start the lamp,
but the light output can be very low if the bulb wall temperature
is low. Several factors influence this, including ambient temperatures, wind, type of enclosure, etc. If maximum light output is
critical, consult a lamp manufacturer for advice.
1. Mount the ballast against a flat surface of heavy gauge
metal such as the structural part of the sign.
2. Keep the ballast as far away as possible from other ballasts,
lamps or reflective surfaces. (Lamps generate approximately
three-fourths of the heat in a plastic sign.) The ends of the
lamps are the hottest part, so you should mount the ballast
as far away from the ends as possible.
3. Paint the inside of the sign with flat white paint.
Moisture Protection
1. Vent the sign as well as possible without allowing
water to enter.
2. Ballasts should be mounted horizontally (except for
weatherproof types). If the ballast must be mounted
vertically, allow room for sufficient air circulation.Wherever
possible, mount the ballast in an enclosure outside the sign
by using Universal pup tents. You can get pup tents when
you order the plastic sign ballast. Your wholesaler will also
have a supply for your convenience.
Grounding
Plastic Sign Ballasts
The white lead of a ballast must be connected to the neutral
or ground side of the power supply. All metal parts of the sign,
as well as the ballast case, must be grounded either through
the conduit which holds the power supply or by direct connection with a grounding wire. An ungrounded sign is a potential
hazard—and it can give misleading symptoms when looking
for sign faults.
Lamp Starting Problems
Occasionally a field problem will arise involving improper lamp
starting. The usual complaint is that the lamps start slowly (or
not at all). Here are some of the causes:
1. Low line voltage
2. Improper sign grounding
3. Insufficient or no open circuit voltage
4. Dirty lamps during high-humidity operating conditions
5. Lamps improperly inserted in the sockets
If lamp starting is a problem in your installation, check the sign
grounding and open circuit voltage. If both are normal, the
probable cause is dirty lamps. The lamps should be washed
in clean water, drip-dried, and reinstalled. If this doesn’t solve
the problem, contact your nearest Universal representative for
further assistance.
Short Lamp Life
If the lamp has not given proper length of service as specified
by the lamp manufacturer, the following reasons
for early failure should be considered:
1. Frequent starting and short operating periods
2. Improper ballast
3. Improper voltage supply
4. Faulty wiring
5. Defective lamps
6. Lamps improperly inserted in sockets
Early lamp failure will be preceded by a dense blackening on
either or both ends of the lamps. This blackening will extend
three or four inches from the lamp base and should not be
confused with a small dense spot, which is a mercury deposit
that can occur any time during lamp life. Dense blackening
due to early lamp failure should not be confused with the gray
bands that sometimes appear toward the end of normal lamp
life (about two inches from either end of the lamp).
PAGE 7-2
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Sign Ballast Footage Chart
ELECTRONIC SIGN BALLASTS
No. of Lamps
Per Ballasts
T12HO Lamps
T8HO Lamps
TOTAL FOOTAGE FOR T12HO & T8HO LAMPS
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
ESB-216-12 (Up to 8’ Lamps)
1-2
ESB-216-12 (Up to 6’ Lamps)
ESB-432-14 (Up to 8’ Lamps)
1-4
ESB-432-14 (Up to 6’ Lamps)
ESB-848-46 (Up to 8’ Lamps)
4-6
ESB-848-46 (Up to 6’ Lamps)
ESB-1040-14 (Up to 10’ Lamps)
1-4
ESB-1040-14 (Up to 8’ Lamps)
PLASTIC SIGN BALLAST LEAD LENGTHS (INCHES)
CATALOG NUMBER
WHITE
BLACK
BLUES
REDS
SIGNA ELECTRONIC SIGN BALLASTS - T8 & T12 HIGH OUTPUT LAMPS - 108-35 Volts - 50-60 Hz
SIX LAMP BALLASTS
ESB216-12
24
24
120
120
ESB432-14
24
24
120
120
ESB848-46
24
24
120
120
ESB1040-46
24
24
120
120
Note: Maximum volts above ground, any lead 590 volts.
Plastic Sign Ballasts
PAGE 7-3
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
ELECTRONIC
SIGN
BALLASTS
SIGNA® ELECTRONIC
SIGN BALLASTS
• Instant start for maximum energy savings
• Simplified wiring for fewer connections
• Universal input voltage
• Parallel Lamp Operation
PLASTIC SIGN BALLAST LEAD LENGTHS (INCHES)
TOTAL LAMP
FOOTAGE
CATALOG NUMBER
START
TEMP (ºF)
INPUT
VOLTAGE
MAX. INPUT
VOLTAGE
MAX. LINE
CURRENT (A)
WIRING
DIAGRAM
DIMENSION
CHART REF.
WEIGHT
(LBS.)
1
1
4.2
2
2
7.4
3
3
9.7
2
3
10
T12HO UP TO 8’ IN LENGTH OR T8HO UP TO 6’ IN LENGTH - 120 to 277 Volts - 50/60 Hz
ONE TO TWO LAMP BALLASTS
ESB216-12
2’ min. – 16’ max.
–20
120
134
1.12
277
130
0.47
ONE, TWO, THREE OR FOUR LAMP BALLASTS
ESB432-14
4’ min. – 32’ max.
–20
120
280
2.34
277
274
0.99
FOUR, FIVE OR SIX LAMP BALLASTS
ESB848-46
8’ min. – 48’ max.
–20
120
408
3.41
277
395
1.47
T12HO UP TO 10’ IN LENGTH OR T8HO UP TO 8’ IN LENGTH - 120 to 277 Volts - 50/60 Hz
ONE, TWO, THREE OR FOUR LAMP BALLASTS
ESB1040-14
10’ min. – 40’ max.
–20
120
341
2.85
277
331
1.25
Consult www.signasign.com for complete specification information
Diagram 2
Diagram 1
Diagram 3
ELECTRONIC SIGN BALLASTS
DIMENSION CHART - STANDARD CASE (INCHES)
Ref. #
1
2
3
A
B
C
D
E
10 37/64 ˝ 1145/64˝ 119/64˝ 13/4˝ 3 3/16˝
133/16˝ 14 5/16˝ 13 3/4˝ 2 43/64˝ 3 3/16˝
15 9/16˝ 16 11/16˝ 161/8˝ 2 43/64˝ 3 3/16˝
Diagrams Notes:
When Operating less than the
maximum number of lamps,
insulate unused blue leads.
SIGNA WIRE BLOCK
Electronic Sign Ballasts
For use converting magnetic ballast installations to electronic systems.
CATALOG
NUMBER
MAGNETIC
BALLASTS
NUMBER OF
LAMPS OPERATED
FOR USE WITH:
WB66
6 Lamps
6 Lamps
ESB848-46
WB65
6 Lamps
5 Lamps
ESB848-46
WIDTH
3.00 in (76.2 mm)
WB64
6 Lamps
4 Lamps
ESB848-46
HEIGHT
0.75 in (19.05 mm)
WB44
4 Lamps
4 Lamps
ESB432-14 / ESB1040-14
WEIGHT
0.06 lbs.
PHYSICAL PROPERTIES
LENGTH
6.00 in (152.4 mm)
WBEXT – 24” wiring harness for extending magnetic ballast leads.
PAGE 7-4
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Notes
Plastic Sign Ballasts
PAGE 7-5
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Glossary
ANSI (American National Standards Institute): Non-profit organization
that generates voluntary product performance standards for many U.S.
industries. ANSI Standard C82.11 applies to high frequency fluorescent
lamp ballasts.
Harmonic: An integral multiple of the fundamental frequency (60 Hz)
that becomes a component of the current (see “Harmonic Distortion”).
Arc: Intense luminous discharge formed by the passage of electric
current across a space between electrodes.
Harmonic Distortion: Distortion of an AC waveform caused by multiples
of the fundamental frequency (harmonics). Odd triplet harmonics (thirds,
ninths, etc.) may result in large currents on the neutral line in a four-wire
Wye three-phase system.
Auto Reset Shutdown Circuit: Circuit senses lamp end of life and will
automatically shut off power to the lamp(s). When a new lamp is inserted
in the socket, the ballast resets, and turns on the lamp automatically.
High Efficiency (Energy Saving) Electromagnetic Ballast: Ballast
with Core & Coils, designed to minimize ballast losses compared to
the “standard” ballast.
Ballast Efficacy Factor (BEF): Value used to evaluate various lighting
systems based on light output and power input. The BEF can only be
used to compare systems operating the same type and quantity of lamps.
High Intensity Discharge (HID) Lamp: A lamp containing a filled arc
tube in which the active element becomes vaporized (a gaseous state)
and is discharged into the arc stream to produce light.
Ballast Factor (BF): Measure of light output from lamp operated by
commercial ballast as compared to a laboratory standard reference
ballast. Ballast factor .94 means ballast produces 94% of light
produced by ANSI C82.2 reference ballast operating same lamps.
High Power Factor: A ballast whose power factor is corrected to
90% or greater.
Ballast Luminous Efficiency (BLE): New ballast efficiency metric
introduced by DOE. Equal to the ratio of total lamp arc power to ballast
input power.
Incandescent Lamp: Lamp in which light is produced by a filament
heated by an electric current.
Input Voltage: Power supply voltage required for proper operation of
an arc discharge lighting ballast.
Canadian Energy Standards: Indicates ballast complies with
Canadian Energy Standards and meets the requirements of
CAN/CSA-C654-M91.
Instant Start (IS): Lamp starting method in which lamps are started
by high voltage input with no preheating of lamp filaments. Some
rapid start lamps are designed so that they may be instant started.
Canadian Standards Association (CSA): Association that
generates product performance and safety standards for many
Canadian industries.
LED: Light Emitting Diode (LED) is a diode that produces light when
the electrical current flows through it.
Circle E: Designates a ballast meets or exceeds the
E requirements of Public Law 100-357 establishing standards
of efficiency.
Constant Current LED System: System where the driver provides a
constant output current and the modules are designed for that current
rating or higher. Modules are constant current rated and have no
current limiting.
Constant Voltage LED System: System where the driver provides a
constant voltage output and the modules incorporate an integral current
control device to regulate the LED current within the module. Drivers
and modules must both have the same constant voltage rating and
power loading must be compatible.
Efficacy: Lumen output per unit of power supplied to ballast (lumens
per watt).
EMI (Electromagnetic Interference): Electrical interference (noise)
generated by electrical and electronic devices. Levels generated by
high frequency electronic devices are subject to regulation by Federal
Communications Commission (FCC).
Filament Voltage: Voltage applied to the lamp cathode.
Foot Candles: Measure of light level on a surface being illuminated.
Defined as one lumen of light per one square foot of surface area.
LED Module: A single component that includes LEDs,
electrical connections, mounting plate/housing, optical interface,
environmental protection, thermal interface and heat sinking.
Lumens/Watt: A measurement of white light produced by each
output watt.
Parallel Lamp Operation: Refers to ballasts that employ multipleoutput current paths independent of one another, allowing other lamps
operated by the ballast to remain lit should companion lamp(s) fail.
Programmed Rapid Start (also Programmed Start): lamp starting
method which preheats the lamp filaments while not allowing the
lamp to ignite and then applies the open circuit voltage (OCV) to start
the lamp. This type of starting circuit keeps lamp end blackening
to a minimum and improves lamp life performance, especially in
applications where the lamps are frequently switched on and off.
Rapid Start (RS): Lamp starting method in which lamp filaments
are heated while open circuit voltage (OCV) is applied to facilitate
lamp ignition.
Series Lamp Operation: Refers to ballasts that employ a single
current path passing through all lamps operated by the ballast.
If one lamp should fail, companion lamps operated by the same
ballasts will also extinguish or dim.
FOR MORE INFORMATION CALL
PAGE 8-1
1-800-BALLAST
(225-5278)
Glossary
Crest Factor (Lamp Current Crest Factor): Ratio of peak lamp
current to RMS or average lamp operating current.
LED Driver: Similar to the function of a fluorescent ballast.
It regulates output voltage or current for the LED module.
Glossary
Trigger Start: A term used for electromagnetic ballasts which operate
pre-heat start lamps in a rapid start manner. They supply higher filament
voltages to heat the electrodes to start the pre-heat lamps, to simulate
the rapid start system. A grounded reflector close to the lamp, together
with a grounded line circuit, is required to provide a capacitive starting
aid effect between lamps and fixture and assist ionization in the starting
process.
UL (Underwriters’ Laboratories, Inc.): Laboratory that sets safety
standards for building materials, electrical appliances and other products.
Glossary
Watts: Measurement of electrical ability to do work
FOR MORE INFORMATION CALL
PAGE 8-2
1-800-BALLAST
(225-5278)
Index
Catalog
Page #
Catalog
Page #
100305
6-9
109459
6-12
100310
100720
100732
100912
100928
100946
101035
101248
101485
101489
101491
101493
101521
102597
102927
102929
106457
107065
107195
107652
107677
107694
108257
108756
108851
108869
108870
108891
108892
108893
108913
108925
108979
109014
109235
109237
109239
109240
109241
109272
109342
109343
109376
109377
109450
6-11
6-16
6-11
6-15
6-15
6-16
6-19
6-19
6-19
6-19
6-19
6-12
6-15
6-15
6-16
6-11
6-16
6-11
6-11
6-15
6-11
6-16
6-12
6-12
6-12
6-12
6-15
6-11
6-11
6-15
6-16
6-12
6-19
6-19
6-19
6-19
6-19
6-19
6-12
6-6
6-6
6-6
6-6
6-16
109460
109518
109547
109851
109852
109852
109853
109855
109856
11102-45SC-TC
1110-246C-TC
1110-247SC-TC
1110-564C-TC
1110-566C-TC
1110-568C-TC
1111-246C-TC
1111-247SC-TC
1120-251A-TC
11210-236C-TC
11210-239C-TC
11210-242C-TC
11210-277C-TC
11210-490C-TC
11210-506C-TC
11210-539C-TC
11210-554C-TC
11210-606C-TC
12210-236C-TC
12210-237C-TC
12210-239C-TC
12210-241C-TC
12210-261C-TC
12210-261RC-TC
12210-552C-TC
12210-602C-TC
12210-606C-TC
123310W
1233142W
1233154W
1233251W
123335W
188156
188157
188164
188165
188166
6-12
6-12
6-16
6-15
6-15
6-15
6-15
6-15, 6-16
6-15
4-35
4-35
4-35
4-35
4-35
4-35
4-35
4-35
4-35
4-35
4-35
4-35
4-35
4-35
4-35
4-35
4-35
4-35
4-36
4-36
4-36
4-36
4-36
4-36
4-36
4-36
4-36
4-27
Index
109238
6-9
6-16
4-27
4-28
4-27
4-27
5-3
5-3
5-3
5-3
5-3
FOR MORE INFORMATION CALL
PAGE 9-1
1-800-BALLAST
(225-5278)
Index
Catalog
Page #
Catalog
Page #
188167
5-3
400036
6-16
188168
188169
188246
188301
188302
188514
188574
188610
188611
188612
188613
188629
188630
188631
188632
188633
188634
188635
188638
188639
188649
188650
188651
188652
188671
188754
188756
188757
188758
188776
188777
188841
188882
188883
Index
188884
188885
188895
188896
188897
188901
188902
188903
188939
188940
188941
188989
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
5-3
400080
404681
500574
500575
501981
501982
502004
502394
504262
504542
505732
505733
505734
505735
505736
505737
505739
505745
505746
505747
505750
505751
506216
506381
507656
507992
507993
507994
507995
508306
508314
508590
508610
508611
509035
509069
509134
509135
509136
509137
509180
509213
509356
509357
520728
525523
6-16
6-7
6-19
6-19
6-12
6-12
6-15
6-11
6-12
6-15, 6-16
6-9
6-9
6-9
6-9
6-9
6-9
6-9
6-9
6-9
6-9
6-9
6-9
6-11
6-12
6-11
6-19
6-19
6-19
6-19
6-15
6-19
6-9
6-15
6-15
6-15
6-15
6-6
6-6
6-6
6-6
6-6
6-11
6-11
6-15
6-15
6-12
FOR MORE INFORMATION CALL
PAGE 9-2
1-800-BALLAST
(225-5278)
Index
Catalog
Page #
Catalog
Page #
525681
6-15
536284
6-5
525681
525750
525857
525857
526018
526211
526246
526251
526755
527560
527561
527564
527565
527566
527589
527590
527594
527595
527596
527794
527795
527798
527799
527800
528120
528121
528124
528125
528126
529699
529773
529773
530250
532685
532687
532689
534050
534101
534102
534105
534132
534218
534219
534636
535782
6-15
6-15
6-11
6-11
6-11
6-11
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-19
6-15
6-11
6-11
6-15
6-19
6-19
6-19
6-19
6-11
6-11
6-11
6-11
6-15
6-11
6-11
6-11
6-11
536293
536294
536297
536298
536300
536301
536303
536304
536306
536307
536309
536310
536312
536313
536315
536316
536320
536322
536325
536328
536329
536330
536336
536337
536338
536344
536346
536347
536348
536349
536350
536368
536369
536370
536372
536373
536469
536822
536856
536857
536857
537049
537057
537132
537138
537141
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-5
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
Index
532691
6-15
6-11
6-11
6-16
6-15
6-15
6-11
6-11
6-5
6-5
6-5
FOR MORE INFORMATION CALL
PAGE 9-3
1-800-BALLAST
(225-5278)
Index
Catalog
Page #
Catalog
Page #
537147
6-5
005-1418-BH
4-4
537150
537155
537165
537166
537173
537174
537175
537181
537182
537183
537205
537206
537207
537454
537784
538286
538630
538634
542157
542304
543153
543963
545840
545842
545845
545849
545858
545862
545894
545896
545933
545935
545937
545939
Index
547807
547808
001-2009
005-1184-BH
005-1185-BH
005-1401-BH
005-1410-BH
005-1411-BH
005-1413-BH
005-1414-BH
005-1415-BH
005-1417-BH
6-5
6-5
6-5, 6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-7
6-11
6-11
6-15
6-11
6-11
6-11
6-11
6-11
6-11
6-6
6-6
6-6
6-6
6-6
6-6
6-9
6-9
6-9
6-9
6-9
6-9
6-11
6-11
4-37
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
005-1421-BH
005-1422-BH
005-1464-BH
005-1466-BH
005-1467-BH
005-1468-BH
005-1474-BH
005-1475-BH
005-1495-BH
005-1561-BH
005-1594-BH
005-1799-BH
005-1884-BH
005-1886-BH
005-1887-BH
005-1888-BH
005-1893-BH
005-2167-BH
005-2351-BH
005-2669-BH
005-2776-BH
005-2779-BH
005-2793-BH
005-3160-BH
005-3278-BH
493B2
B114PUNV70-D
B114PUNVDV3-D
B114PUNVSV3-D
B128PUNV50-D
B128PUNV60-D
B128PUNV70-D
B128PUNVDV3-D
B128PUNVSV3-D
B132I347HP
B132IUNVHE-N
B132IUNVHP-N
B132PUNVDV3-A
B132PUNVSV3-A
B132R347V5
B135PUNV70-D
B135PUNVDV3-D
B135PUNVSV3-D
B214PU115S50A
B214PUNVDV3-D
B214PUNVSV3-D
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
4-4
1-46
1-36
2-16
2-17
1-36, 1-37
1-36, 1-37
1-36, 1-37
2-16
2-17
1-13, 1-15, 1-19
1-13, 1-15, 1-17, 1-19, 1-24, 1-26, 1-29, 1-32
1-13, 1-15, 1-19, 1-24, 1-26, 1-29, 1-32
2-16
2-17
2-18
1-37
2-16
2-17
2-20
2-16
2-17
FOR MORE INFORMATION CALL
PAGE 9-4
1-800-BALLAST
(225-5278)
Index
Catalog
Page #
Catalog
Page #
B224PUNV-C
1-38, 3-16, 3-17
B232SR277S30
2-19
B228P3DV3PLA
B228P3DV3PLD
B228P3SV3PLA
B228PU115S50D
B228PU95S50D
B228PUDV3PLA
B228PUDV3PLD
B228PUNV-C
B228PUNV-N
B228PUNV115-D
B228PUNV85-D
B228PUNV90-C
B228PUNV95-D
B228PUNVDV3-D
B228PUNVSV3-D
B228PUSV3PLA
B232I120RES-A
B232I120RES-G
B232I347HP-A
B232I347HPL
B232IUNV-C
B232IUNV104-A
B232IUNVEL-N
B232IUNVHEH-A
2-17
B232SR347V5
2-17
B234SR120M-A
2-23
B234SR277M-A
2-20
B239PUNV-D
2-20
B240R220-A
2-17
B254P347-D
2-17
B254P3DV3PLD
1-36, 1-37
B254P3SV3PLD
1-36, 1-37
B254PHRVHB-E
1-9, 1-36, 1-37
B254PUDV3PLD
1-9, 1-36, 1-37
B254PUNV-D
1-9, 1-36, 1-37
B254PUNVHB-D
1-36, 1-37
B254PUNVPL-A
2-16
B254PUNVPLHBA
2-17
B254PUSV3PLD
2-23
B259I347HP
1-13, 1-15, 1-19, 1-20
B259IUNVEL-A
1-13, 1-15, 1-19, 1-20
B259IUNVHE-A
1-13, 1-15, 1-19, 1-20, 1-24, 1-29, 1-32
B259IUNVHP-A
1-13, 1-15, 1-19, 1-20, 1-32
B260I120M-A
1-13, 1-15, 1-19, 1-20, 1-32, 1-42
B260IUNVHP
1-13, 1-15, 1-26, 1-29
1-13, 1-15, 1-19, 1-20, 1-24, 1-26, 1-29
B286PUNVHE-S
B295PUNVHE-S
B232P3DV3PLD
2-17
B332IUNVEL-A
B232P3S50PLA
2-26, 2-27
B332IUNVHE-A
B232P3S50PLHA
2-25
B332IUNVHP-A
B232P3SV3PLA
2-22
B332PUNVEL-A
B232PUDV3PLA
2-17
B332PUNVHE-A
B232PUDV3PLD
2-17
B332PUNVHEH-A
B232PUNVDV3-A
2-16
1-8, 1-14, 1-15, 1-19, 1-21, 1-24, 1-25, 1-26,
1-27, 1-29, 1-30, 1-32
1-8, 1-14, 1-15, 1-19, 1-21, 1-24, 1-25, 1-26,
1-27, 1-29, 1-30, 1-32
1-8, 1-14, 1-15, 1-19, 1-21, 1-24, 1-25, 1-26,
1-27, 1-29, 1-30
2-26, 2-27
B232IUNVHP-N
B232PUNVEL-B
B232PUNVHE-B
B232PUNVHEH-A
B232PUS50PLA
B232PUS50PLHA
2-25
1-42, 1-43
1-38, 3-17
1-43
1-38, 3-18, 3-19
2-17
2-24
1-38, 3-18, 3-19
2-17
1-38, 1-39, 1-40, 3-15, 3-17, 3-18, 3-19
1-38, 1-39, 1-40, 3-15, 3-17, 3-18, 3-19
1-38, 1-39, 1-40, 1-41, 3-15, 3-17, 3-18, 3-19
1-38, 1-39, 1-40, 1-41, 3-15, 3-17, 3-18, 3-19
2-24
1-32, 1-34
1-34
1-34
1-34
1-44, 1-45
1-44, 1-45
1-35
1-46
B332I347HP
1-14, 1-16, 1-20, 1-21, 1-32, 3-17
B332I347HPL
1-14, 1-16, 1-20, 1-21, 1-32
B332IHRVHB-E
B332SR120S30
1-20, 1-21, 1-24, 1-25, 1-26, 1-27, 1-29, 1-30
1-14, 1-16, 1-20, 1-21, 1-24, 1-25, 1-26, 1-27,
1-29, 1-30, 1-32
1-14, 1-16, 1-20, 1-21, 1-24, 1-25, 1-26, 1-27,
1-29, 1-30, 1-32
1-14, 1-16, 1-20, 1-21, 1-24, 1-25, 1-26, 1-27,
1-29, 1-30, 1-32, 1-42
1-8, 1-14, 1-16, 1-21, 1-22, 1-25, 1-27, 1-28,
1-30, 1-32
1-8, 1-14, 1-15, 1-16, 1-21, 1-22, 1-25, 1-27,
1-28, 1-30
1-8, 1-14, 1-15, 1-16, 1-21, 1-22, 1-25, 1-27,
1-28, 1-30
2-19
B332SR120V5
2-18
B332SR277S30
2-19
B332SR277V5
2-18
B432I120RES-A
1-14, 1-16, 1-17, 1-21, 1-22
B432I347HP
B232PUSV3PLA
2-22
B432I347HPL
B232SR120S30
2-19
B432IUNVEL-A
1-14, 1-17, 1-21, 1-22, 1-33
1-14, 1-17, 1-21, 1-22, 1-33
1-14, 1-17, 1-21, 1-22, 1-25, 1-26, 1-30, 1-31,
1-33
FOR MORE INFORMATION CALL
PAGE 9-5
1-800-BALLAST
(225-5278)
Index
B232P3DV3PLA
1-13, 1-15, 1-19, 1-20, 1-24, 1-26, 1-29
1-13, 1-15, 1-17, 1-19, 1-20, 1-24, 1-26, 1-29,
1-32
2-17
2-18
1-42, 1-43
Index
Catalog
B432IUNVHE-A
B432IUNVHP-A
B432PUNVEL-A
B432PUNVHE-A
B432PUNVHEH-E
B432SR277V5
B454PUNV-E
B454PUNVHB-E
B454PUNVPL-E
B454PUNVPLHBE
C140PUNVDV3
C213/347ME
C213UNVDV3ME
C213UNVME
C213UNVSV3ME
C218/347ME
C218UNVDV3ME
C218UNVME
C218UNVSV3ME
C226UNVDV3ME
C226UNVSV3ME
C232PUNVDV3
C240PUNVDV3
C240PUNVHP-B
C240SI120RH
C240SI277RH
C242/347ME
C242PUNVDV3
C2642/347ME
C2642UNVME
C340SI120RH
C340SI277RH
CF1320H2P
Index
CT213UNVME
CT218UNVME
ES1329A
ES1510A
ES1786X
ESB1040-14
ESB216-12
ESB432-14
ESB848-46
HPS10004B
HPS10005A
HPS1503A
Page #
1-14, 1-17, 1-21, 1-22, 1-25, 1-26, 1-27, 1-28,
1-30, 1-31, 1-33
1-14, 1-17, 1-21, 1-22, 1-25, 1-26, 1-27, 1-28,
1-30, 1-31, 1-33, 1-42
1-8, 1-14, 1-17, 1-22, 1-25, 1-26, 1-28, 1-30,
1-31, 1-33
1-8, 1-14, 1-16, 1-17, 1-22, 1-25, 1-26, 1-28,
1-30, 1-31
2-18
1-38, 1-39, 3-18, 3-19
1-38, 1-39, 3-18, 3-19
1-38, 1-39, 1-40, 1-41, 3-18, 3-19
1-38, 1-39, 1-40, 1-41, 3-18, 3-19
2-16
3-2, 3-9, 3-12
2-16
3-2, 3-7, 3-9, 3-12
2-17
3-2, 3-9, 3-12
2-16
3-2
2-17
2-16
2-17
2-16
2-16
3-7, 3-17
3-17
3-17
3-9, 3-10, 3-13, 3-15, 3-16, 3-18
2-16
3-2, 3-9, 3-10, 3-13, 3-15, 3-16
3-2
3-17
3-17
3-9
3-9
3-16
1-15, 1-21
1-13, 1-15, 1-19
1-47
7-4
7-3, 7-4
7-3, 7-4
7-3, 7-4
4-25, 4-30, 4-33, 4-38, 4-39
4-38, 4-39
4-27, 4-33, 4-38, 4-39
Catalog
Page #
HPS15045B
4-38, 4-39
HPS1504A
4-38, 4-39
HPS1505A
4-38, 4-39
HPS1505B
4-38, 4-39
HPS150G01W
4-38, 4-39
HPS4003A
HPS40045B
HPS4004A
HPS400G05W
HPS4501B
HPS4601B
HPS6001B
M1000120AC5M
M1000230AC5M
M100048TAC5M
M1000ML5AC5M
M1000MLTAC5M
M1000TRIAC5M
M10048TLC3M
M100MLTLC30
M100MLTLC3D
M100TRILC3M
M1500230AC5M
M150048TAC5M
M1500MLTAC5M
M1500TRIAC5M
M150277RCEM
M15048TLC3M
M150MLTAC3M
M150MLTLC3D
M150MLTLC3M
M150TRILC3M
M175230AC3M
M17548TAC3M
M175ML5AC3M
M175MLTAC3M
M175TRIAC30
M250230AC3M
M25048TAC3M
M250ML5AC3M
M250ML5AC4M
M250MLTAC3M
M250MLTAC4M
M250TRIAC3M
M250TRIAC4M
4-28, 4-29, 4-33, 4-38, 4-39
4-38, 4-39
4-38, 4-39
4-38, 4-39
4-38, 4-39
4-38, 4-39
4-30, 4-38, 4-39
4-18
4-33
4-12, 4-18
4-12, 4-18
4-12, 4-18
4-15, 4-18
4-13, 4-20
4-20
4-13, 4-20
4-15, 4-20
4-33, 4-34
4-12, 4-18
4-12, 4-18
4-15, 4-18
4-21
4-13, 4-21
4-13, 4-21
4-13, 4-21
4-13, 4-21
4-15, 4-21
4-33
4-12, 4-16
4-12, 4-16
4-12, 4-16
4-15, 4-16
4-33
4-12, 4-16
4-12, 4-16
4-12, 4-17
4-12, 4-16
4-12, 4-17
4-15, 4-16
4-15, 4-17
FOR MORE INFORMATION CALL
PAGE 9-6
1-800-BALLAST
(225-5278)
Index
Catalog
Page #
Catalog
Page #
M35MLTLC3M
4-13, 4-20
P400ML5AC4M
4-24
M35TRILC3M
M400120AC4M
M400230AC4M
M40048TAC4M
M400ML5AC4M
M400MLTAC4M
M400TRIAC40
M400TRIAC4M
M50MLTLC3M
M50TRILC3M
M7048TLC3M
M70MLTLC3D
M70MLTLC3M
M70TRILC3M
P100048TAC5M
P1000ML5AC5M
P1000MLTAC5M
P175277RCEM
P17548TAC3L
P175MLTAC4L
P175TRIAC3M
P20048TAC3L
P200ML5AC3M
P200MLTAC3L
P200TRIAC3M
P25048TAC4L
P250ML5AC4L
P250MLTAC4L
P250TRIAC4M
P320277RCEM
P32048TAC4L
P320ML5AC4L
P320ML5AC4M
P320MLTAC40
P320TRIAC4M
P35048TAC4O
P350ML5AC40
P350ML5AC4L
P350ML5AC4M
P350MLTAC40
P350MLTAC4M
P350TRIAC4M
P40048TAC4L
P40048TAC4M
P400ML5AC4L
4-33
4-12, 4-17
4-12, 4-17
4-12, 4-17
4-17
4-15
4-13, 4-20
4-15, 4-20
4-13, 4-20
4-13, 4-20
4-13, 4-20
4-15, 4-20
4-25
4-13, 4-25
4-13, 4-25
4-21
4-13, 4-21
4-13, 4-21
4-15, 4-21
4-13, 4-22
4-13, 4-22
4-13, 4-22
4-15, 4-22
4-13, 4-22
4-13, 4-22
4-13, 4-22
4-15, 4-22
4-22
4-13, 4-23
4-13, 4-23
4-13, 4-23
4-22
4-15, 4-22
4-23
4-13, 4-23
4-13, 4-23
4-13, 4-23
4-13
4-23
4-13, 4-23
4-15, 4-23
4-13, 4-24
4-24
4-13, 4-24
P400MLTAC4L
P400TRIAC4M
P45048TAC4L
P450ML5AC4L
P450MLTAC4L
P75048TAC5M
P750ML5AC5M
P750MLTAC5M
P750TRIAC5M
P875MLTAC5M
R17058501-BH
R17058503-BH
R17058507-BH
R17058509-BH
R17058511-BH
R17058514-BH
R17058515-BH
R17058517-BH
R17058519-BH
R17058520-BH
R17058522-BH
R17058523-BH
R17058529-BH
R17058530-BH
R17058532-BH
R17058533-BH
R17058535-BH
R17058536-BH
R17058543-BH
R17058553-BH
R17058554
R17058555-BH
R17058557-BH
R17058558-BH
R17058560
R17058562-BH
R17058563-BH
R17058564
R17058565-BH
R17058567-BH
R17058569
R17058571-BH
R17058574-BH
S1000230AC5M
S1000480AC5M
S100048TAC5M
4-13, 4-24
4-15, 4-24
4-13, 4-25
4-13, 4-25
4-13, 4-25
4-13, 4-25
4-13, 4-25
4-13, 4-25
4-15, 4-25
4-13, 4-25
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
4-5
Index
P35048TAC4L
4-15, 4-20
4-17
4-5
4-5
4-5
4-5
4-5
4-5
4-33
4-30
4-14, 4-30
FOR MORE INFORMATION CALL
PAGE 9-7
1-800-BALLAST
(225-5278)
Index
Catalog
Page #
S1000ML5AC5M
4-14, 4-30
S1000TRIAC5M
4-15, 4-30
S1000MLTAC5M
S100120RCEM
S10048TLC3M
S100MLTLC3M
S100TRILC3M
S150120RCEM
S15048TLC3M
S150TRILC3M
S20048TAC4M
S200MLTAC4M
S200TRIAC4M
4-14, 4-27
4-14, 4-27
4-15, 4-27
4-28
4-14, 4-28
4-15, 4-28
4-14, 4-28
4-14, 4-28
4-28
S25048TAC4M
4-14, 4-28
S250TRIAC4M
S35120RCEM
4-33
4-14, 4-28
4-28
4-27
S400230AC4M
4-33
S40048TAC5M
4-14, 4-29
S40048TAC4M
4-14, 4-29
S400ML5AC4M
4-14, 4-29
S400MLTAC4M
4-14, 4-29
S400ML5AC5M
S400MLTAC5M
S400TRIAC4M
S400TRIAC5M
S430MLTAC4M
S50120RCEM
S50MLTLC3M
S600MLTAC5M
S70120RCEM
S70230LC3M
S7048TLC3M
S70MLTLC3M
Index
4-27
4-28
S250MLTAC4M
S70TRILC3M
Page #
4-14, 4-30
S250120AC4M
S250230AC4M
Catalog
4-14, 4-29
4-14, 4-29
4-15, 4-29
4-15, 4-29
4-29
4-27
4-14, 4-27
4-14, 4-30
4-27
4-33, 4-34
4-14, 4-27
4-14, 4-27
4-15, 4-27
FOR MORE INFORMATION CALL
PAGE 9-8
1-800-BALLAST
(225-5278)
Universal Lighting Technologies Limited Warranty
TM
LIMITED WARRANTY. Universal Lighting Technologies, 51 Century Blvd., Suite 230, Nashville, TN 37214-3683, 1-800-BALLAST, (hereinafter called “Universal”)
warrants to the purchaser and first end-user purchaser only, that its lighting products (hereinafter called “Lighting Products”) will be free from defects in material
and workmanship for the specified warranty periods listed below (each hereinafter called a “Warranty Period”). If any Lighting Product does not meet the limited
warranty provided in the preceding sentence and such defect is reported to Universal during the applicable Warranty Period, then the sole obligation of Universal,
and the SOLE AND EXCLUSIVE REMEDY under this limited warranty, shall be limited to the replacement of such non-performing Lighting Product with, at Universal’s
sole discretion, the same type of Lighting Product or a Lighting Product which is substantially similar thereto. Other than with respect to the duration of the
Warranty Period for the items denoted below with a (“*”) or separately agreed to in a written agreement, if any term or condition of this limited warranty conflicts
with any term or condition of contained on any other document, including but not limited to Universal’s Terms and Conditions of Sale or any product specification
sheet, Application and Performance Data Sheet or similar document for any Lighting Product (collectively “Product Specification Sheet”), the terms and conditions of
this limited warranty shall control.
WARRANTY PERIODS. All Warranty Periods are measured beginning from the date of manufacture. Lighting Products not falling within one of the below listed
categories shall have a Warranty Period of 12 months. The applicable Warranty Period for the type of Lighting Products listed below are as follows:
TRIAD Electronic Fluorescent Ballasts up to 60 Months*
Universal, Energy Saving Electromagnetic Fluorescent Ballasts
36 Months
AddressPro, and DaliPro Ballasts 36 Months
SuperDim, LevelPro & VariPro 60 Months
Standard Universal Electromagnetic, Fluorescent & H.I.D. Ballasts 24 Months
Universal Sign Ballasts 24 Months
MAX-3 Series Sign Ballasts 36 Months
36 Months
Basic-12 and Homestar Electronic Ballasts
VS Lampholders 36 Months
VS Brand Magnetic IEC, Electronic IEC, Ignitors, Switches and Capacitors
36 Months
Electronic HID up to 60 Months*
LED Drivers up to 60 Months*
LED Modules
36 Months**
* With respect to the items denoted above with a (“*”), the duration of the Warranty Period will vary depending on the specific Lighting Product.
The exact Warranty Period for the items denoted with (“*”) shall be provided on the Product Specification Sheet, for such Lighting Product.
** COVERED DEFECTS FOR LED MODULES. For purposes of this limited warranty, a defect in a LED Module shall be defined as one or more individual LEDs dark at initial installation or > greater
than 10% of individual LEDs dark during the Warranty Period. The Warranty Periods are based on 4000hrs/yr operation of the LED Lighting Products in normal operating conditions in compliance
with the written specifications of Universal. Replacement and/or repair of individual LED Modules does not extend this limited warranty beyond the original Warranty Period.
EXCLUSIONS; TESTING. This limited warranty is conditional and excludes (i) Lighting Products which have been abused, altered, improperly or insufficiently
maintained, or improperly operated, (ii) normal wear and tear or normal usage, (iii) any Lighting Product not installed and operated in accordance with the National
Electric Code (NEC), the Standards for Safety of Underwriters Laboratories, Inc. (UL), Standards for the American National Standards Institute (ANSI), in Canada, the
Canadian Standards Association (CSA), or the International Electrotechnical Commission (IEC). This limited warranty is not applicable to and excludes any Lighting
Product which has not been installed and operated in accordance with Universal’s specifications and connection diagrams or Lighting Products which have been
submitted to abnormal operating conditions. This includes, but is not limited to, excessive temperatures as specified in Universal’s published literature. The
conditions for any tests (to be) performed on Lighting Products which are claimed to have not performed in accordance with the terms of this limited warranty shall
be mutually agreed upon in writing and Universal may be represented at any such tests.
DISCLAIMER. TO THE FULLEST EXTENT PERMITTED BY LAW, UNIVERSAL DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR
A PARTICULAR PURPOSE, INFRINGEMENT, AND THOSE ARISING OUT OF PERFORMANCE OR DEALING OR USAGE OF TRADE OR ANY OTHER IMPLIED
WARRANTY WITH RESPECT TO ANY LIGHTING PRODUCT(S). To the fullest extent permitted by law the foregoing limited warranty is exclusive and in lieu of all
other statutory, written or oral warranties and no other warranties of any kind, statutory or otherwise, are given or herein expressed.
LIMITATIONS OF LIABILITY. To the fullest extent permitted by Law, this limited warranty sets forth the exclusive remedy available to any permitted claimant and
under no circumstances, whether as a result of breach of contract, breach of warranty, tort, strict liability or otherwise, will Universal be liable for consequential,
incidental, special or exemplary damages, including, but not limited to, loss of profits, loss of use or damage to any property or equipment, cost of capital, cost of
substitute product, facilities or services, down time costs or claims of claimant’s customers. Universal’s liability for all claims of any kind or for any loss or damages
arising out of, resulting from or concerning any aspect of this limited warranty or from the Lighting Products or services furnished hereunder, shall not exceed the
price of the specific Lighting Product which gives right to the claim. This exclusive limited warranty shall not be deemed to have failed its essential purpose as long
as Universal is willing and able to carry out the terms of this limited warranty.
WARRANTY REPORTING. The obligations of Universal under this limited warranty shall not arise unless Universal is notified in writing of a defect that is
accompanied by a written statement specifying the claim of defect within sixty (60) days after an alleged defect is first known and no later than the expiration of the
applicable Warranty Period. Any warranty claims and the supporting statement shall be sent to Universal’s Warranty department at the address listed below.
REQUIRED PROVISIONS DEEMED INSERTED. Each and every provision of any applicable law, regulation, and/or clause which is required by any applicable law
or regulation to be inserted in this limited warranty shall be deemed to be inserted herein, and this limited warranty shall be read and enforced as though it were
included herein, and if through mistake or otherwise any such provision is not inserted, or is not correctly inserted, then upon the written application of Universal
or any purchaser or first end-user purchaser of the Lighting Products, this limited warranty shall forthwith be automatically amended to make such insertion or
correction.
Email: TES@UNVLT.com
PAGE 10-1
FOR MORE INFORMATION CALL
1-800-BALLAST
(225-5278)
Universal Lighting Technologies
51 Century Blvd., Ste 230
Nashville, TN 37215
General Info: (615) 316-5100
For Technical Engineering Services (TES), application
support and warranty information, call 1-800-BALLAST
Website: www.unvlt.com
email: webmaster@unvlt.com
All specification information is subject to
change without notification. ULTNAV0614
Universal Lighting Technologies is a member of the Panasonic Group
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2014:06:11 13:31:45-05:00 Creator : Adobe InDesign CC (Macintosh) Modify Date : 2014:06:11 13:31:45-05:00 Title : Trapped : False XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:06:11 13:31:45-05:00 Creator Tool : Adobe InDesign CC (Macintosh) Format : application/pdf Document ID : uuid:9102e65a-379b-3c48-af33-ba134d894a3c Instance ID : uuid:80d6b52e-062a-d549-b27d-cc39a25cf25d Producer : Adobe PDF Library 11.0 Page Count : 193EXIF Metadata provided by EXIF.tools