Resi 2004 120320 Catalog 1
99142-Catalog 1 99142-Catalog_1 99142-Catalog_1 785901 Batch8 unilog cesco-content
2014-09-05
: Pdf 120320-Catalog 1 120320-Catalog_1 785901 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 72
Download | |
Open PDF In Browser | View PDF |
Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Residential Products Catalog Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Headquartered in Palatine, Ill., the North American Operating Division of Schneider Electric had sales of $2.7 billion in 2002. The North American Operating Division is one of three geographic divisions of Schneider Electric, headquartered in Paris, France, and markets the Merlin Gerin, Square D and Telemecanique brand products to customers in the United States, Canada and Mexico. In the United States, Schneider Electric is best known by its flagship Square D brand, with Telemecanique becoming increasingly known in the industrial control and automation markets and supported by many Square D distributors. For 100 years, Square D has been a marketleading brand of electrical distribution and industrial control products, systems and services. Schneider Electric is a global electrical industry leader with 2003 sales of approximately $9.9 billion. It is the world’s leading manufacturer of electrical distribution, industrial control and automation products and systems, and the only electrical manufacturer dedicated solely to the distribution and control of electricity. The SQUARE D Multi-Link System is a comprehensive home network solution that allows you to maximize the use of your home technology today and ensure that your home has the infrastructure required to support tomorrow’s advances. Whether you need greater functionality for your home office, a local area network, high-speed internet access, or more convenience in accessing your home entertainment equipment, the SQUARE D Multi-Link System offers a reliable, easy-to-use, and affordable solution. With the SQUARE D Multi-Link System, you will be able to: ■ Control video R E Sequipment I D EfromNanyTroom I via A theLunique infrared remote control technology ■ Add system functionality at any time - The SQUARE D Multi-Link System features the industry’s most open design, allowing you to create your own RESIDENTIAL CONSTRUCTION custom system, whether using Square D option upgrades or third-party add-ons. Even with today’s technological advances, you will never have to Scheider Electric is System the leading supplier of electrical worry about your Multi-Link becoming out dated. equipment for residential construction in the United Know you are protected by the leader in electrical protection - Today’s States, Canada and Mexico. Focused residential sales homeowner has more costly electronic equipment than ever before. and that marketing teams concentrate on serving residential Protect equipment with our SURGEBREAKER PLUS Multi-Path Surge Protector. A single perfect complement to your SQUARE D Multi-Link contractors, and multi-family home builders, System, the SURGEBREAKER PLUS provides surge protection up to manufactured electrical 20,000 volts for your housing telephone,companies, video and electrical lines - wholesale all backed by a 5-year $50,000 warranty. distributors and home improvement retailers. P R O D U C T S ■ Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Load Centers and Circuit Breakers Load Centers and Circuit Breakers Product Information . . . . . . . . . . . . . . 2 QO® Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Plug-On Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 QO Circuit Breaker Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 QO Load Centers Series Rating Class 1100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Indoor - Main Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Indoor - Main Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Rainproof - Main Lug, Main Breaker. . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Three Phase - Main Lug, Main Breaker . . . . . . . . . . . . . . . . . . . . . . . 10 Special Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Voltage Testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Homeline® Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Homeline Load Centers Series Rating Class 1170. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Indoor - Main Lug, Main Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Rainproof - Main Lug, Main Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . 18 QO and Homeline Load Centers Indoor - Dimensions, Knockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Rainproof - Dimensions, Knockouts, Bolt-On Hubs . . . . . . . . . . . . . . . 20 QO Load Centers Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Three Phase Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Homeline Load Centers Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . 23 Table of C O N T E N T S Combination Service Entrance Devices CSED Product Information . . . . . Rainproof - Meter-Mains . . . . . Rainproof - All-In-Ones . . . . . . Circuit Breakers, Accessories. . Dimensions . . . . . . . . . . . . . . . Enclosed Molded Case Switches. Circuit Breaker Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 25 26 27 28 29 29 Surge Protection Surge Protection Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . 30 TVSS and Surge Arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Air Conditioning Disconnects Air Conditioning Disconnects Product Information Air Conditioning Disconnects . . . . . . . . . . . . . . . . Voltage Tester . . . . . . . . . . . . . . . . . . . . . . . . . . . Servicepak Power Outlet Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 . . . . . . . . . . . . . . . . . 32 . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . . . . 34 Structured Wiring Square D Structured Wiring Product Information . . . . . . . . . . . . . . . . . . 35 Square D Multi-Link Structured Wiring System . . . . . . . . . . . . . . . . . 36-37 Metering Metering Product Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Individual Meter Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Ganged and Test Block Sockets and Accessories . . . . . . . . . . . . . . . . . 40 Individual Ganged and Test Block Sockets Dimensions . . . . . . . . . . . . . 41 MP Meter-Pak Meter Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42-43 MP Meter-Pak Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 EZ Meter-Pak® Meter Centers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45-50 EZ Meter-Pak Meter Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 EZ Meter-Pak SCCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52-53 Switches Safety Switches and Disconnects Product Information . . . . . . . . . . . . . . 54 General Duty Safety Switches Light Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Accessories, Lug Data and Dimensions . . . . . . . . . . . . . . . . . . . . . . . 56 Double Throw Safety Switches Fusible and Not Fusible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 240 Volt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Application Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60-61 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Square D Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63-64 Square D Conditions of Sale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65-68 1 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Load Centers & C I R C U I T B R E A K E R S QO® Load Centers and Circuit Breakers Square D load centers are the leading choice of electrical contractors and electricians. Every feature of the QO Load Center was designed to provide clear advantages. QO Circuit Breakers also have features no other manufacturer can offer. These quality, industry exclusive products keep Square D ahead of the competition and are builders’ and electrical contractors’ first choice in electrical protection. Load Center Features: ■ Shielded Copper Bus Bar. ■ Available in single and three phase. ■ Ground Bar is included with all main lugs load centers with three mounting locations. ■ Convertible Mains let you meet changing job-site requirements. ■ 22,000/10,000 AIR standard series connected rating. ■ Tangential main service knockouts. ■ Enclosure rotates for top or bottom feed to reduce service cable waste. QO Circuit Breaker Features: Qwik-Open® circuit breaker protection. Exclusive Visi-Trip® red indicator. Quick make - quick break mechanism. Plug-on design, easy to install. ■ ■ ■ ■ Homeline® Load Centers and Circuit Breakers Homeline Load Centers and Circuit Breakers are built with the same Square D quality you have come to expect at a price that makes them the best value in their class. Feature for feature, Homeline products outclass the competition. Features include: ■ Straight-In Mains. ■ Convertible Mains let you meet changing job-site requirements. ■ Split-branch neutral with up to 50% more terminations than required. ■ Bus and interior assembly is among the most rugged in the industry. ■ Three ground bar mounting locations. ■ 22,000/10,000 AIR standard series connected rating. ■ Tangential main service knockouts. ■ Enclosure rotates for top or bottom feed to reduce service cable waste. 2 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® Circuit Breakers with VISI-TRIP® Indicator Class 730, 731, 733 www.SquareD.com For the most up-to-date information QO 1-pole QOT 1-pole Tandem QO Miniature Circuit Breakers Square D QO miniature circuit breakers are plug-on products for use in QO load centers. Plug-On Circuit Breakers—UL Listed Amperes Interrupting Rating (AIR) In Amperes RMS Symmetrical Amperes Ratinga 1-pole—120/240 Vac Catalog Number Price 2-pole—120/240 Vac Common Trip Catalog Number Price 2-pole—240 Vac b Common Trip Catalog Number Price Three-pole—240 Vac Common Trip Catalog Number Price 1 Space Required 1 Space Required QO 2-pole QO Three-pole 2 Spaces Required 3 Spaces Required QO2200 2-pole 200 A 4 Spaces Required 10 QO110 $19.40 15 QO115 cd 19.40 20 QO120 cd 19.40 25 QO125 c 19.40 30 QO130 c 19.40 35 QO135 c 19.40 40 QO140 c 19.40 45 QO145 c 19.40 50 QO150 c 19.40 60 QO160 c 19.40 70 QO170 c 44.70 80 ... ... 90 ... ... 100 ... ... 110 ... ... 125 ... ... 150 ... ... 175 ... ... 200 ... ... Molded Case Switch 60 A max.–240 Vac Molded Case Switch 100 A max.–240 Vac QO210 QO215 c QO220 c QO225 c QO230 c QO235 c QO240 c QO245 c QO250 c QO260 c QO270 c QO280c QO290c QO2100c QO2110c QO2125c QO2150ce QO2175ce QO2200ce ... ... $ 44.70 44.70 44.70 44.70 44.70 44.70 44.70 44.70 44.70 44.70 89.00 126.00 126.00 126.00 285.00 285.00 327.00 327.00 327.00 ... ... ... QO215H QO220H QO225H QO230H ... QO240H ... QO250H QO260H QO270H QO280H QO290H QO2100H ... ... ... ... ... QO200 QO2000f ... $133.00 133.00 133.00 133.00 ... 133.00 ... 133.00 133.00 149.00 210.00 210.00 210.00 ... ... ... ... ... 46.90 133.00 QO310 QO315 c QO320 c QO325 c QO330 c QO335 c QO340 c QO345 c QO350 c QO360 c QO370c QO380c QO390c QO3100c ... ... ... ... ... QO300 QO3000f $ 165.00 165.00 165.00 165.00 165.00 165.00 165.00 165.00 165.00 165.00 210.00 244.00 244.00 244.00 ... ... ... ... ... 165.00 244.00 QO215VH gc QO220VH gc QO225VH gc QO230VH gc QO240VH gc QO250VH gc QO260VH gc QO270VH gc QO280VH gc QO290VH gc QO2100VH gc QO2110VH ghc QO2125VH ghc QO2150VH gce QO2175VH gce QO2200VH gce $ 97.00 97.00 97.00 97.00 97.00 97.00 97.00 149.00 210.00 210.00 210.00 689.00 689.00 707.00 707.00 707.00 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... QO315VH gc QO320VH gc QO325VH gc QO330VH gc QO340VH gc QO350VH gc QO360VH gc QO370VH gc QO380VH gc QO390VH gc QO3100VH gc ... ... ... ... ... $ 247.00 247.00 247.00 247.00 247.00 247.00 247.00 318.00 353.00 353.00 353.00 ... ... ... ... ... QOH240cf QOH245cf QOH250cf QOH260cf QOH270c QOH280c QOH290c QOH2100c QOH2110cf QOH2125c $211.00 211.00 211.00 211.00 352.00 434.00 434.00 434.00 926.00 926.00 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... QH215c QH220c QH225cf QH230c $195.00 195.00 195.00 195.00 ... ... ... ... ... ... ... ... QH315c QH320c QH325cf QH330c 22,000 AIR 15 20 25 30 40 50 60 70 80 90 100 110 125 150 175 200 QO115VH cd QO120VH cd QO125VHc QO130VHc ... ... ... ... ... ... ... ... ... ... ... ... $42.30 42.30 48.50 48.50 ... ... ... ... ... ... ... ... ... ... ... ... 42,000 AIR Circuit Breaker Wire Sizesa Wire Size (AWG) Al Cu #14–8 #14–8 QO . . . (2) #14–10 1-pole #8–2 #8–2 #14–8 #14–8 ... (2) #14–10 #8–2 #8–2 QO #4–2/0 #4–2/0 2-pole #4– 150–200 300 kcmil 300#4– kcmil 10–30 #14–8 #14–8 QO 35–70 #8–2 #8–2 3-pole 80–125 #4–2/0 #4–2/0 #4– QOB-VH 110–150 300#4– kcmil 300 kcmil QOT 15–20 #12–8 #14–8 QO-AFI, 15–30 #12–8 #14–8 QO-GFI & 40, 50, 60 #12–4 #14–6 QO-EPD QO-PL 10–60 #12–2 #14–2 Breaker Type Ampere Rating 10–30 10–30 35–70 10–30 10–30 35–70 80–125 40 45 50 60 70 80 90 100 110 125 Pan Rail Slot Circuit Limiting QOT Tandem Breakers QOT tandem breakers have a mounting cam as shown. Installation into a QO load center can only be made in those positions having a mounting pan rail slot. Meets Par. 408.15 of NEC®. UL Listed as Class CTL. ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 65,000 AIR 15 20 25 30 QH115cd QH120cd QH125cf QH130c $78.00 78.00 78.00 78.00 $338.00 338.00 338.00 338.00 QOT Tandem Circuit Breakers—10,000 AIR Ampere Ratinga 15 & 15 15 & 20 20 & 20 1-pole Tandem 120/240 Vac Catalog No. Price QOT1515c $38.60 QOT1520c 38.60 QOT2020c 38.60 2-pole Tandem 120/240 Vac Catalog No. Price Order two QOT1515 or QOT2020 circuit breakers and handle tie Cat. No. QOTHT at $2.50 for common switching of center two poles. Replacement Tandem Breakers For Use in Old Style Non-Class CTL QO Load Centers—10,000 AIR Ampere Ratinga Mounting Cam Rail Bead ... ... ... ... ... ... ... ... ... ... 10 15 & 15 15 & 20 20 & 20 20 & 30 30 & 20 30 & 30 1-pole—120/240 Vac 1 Space Required Catalog No. Price .... ... QO1515 c $48.50 QO1520 c 48.50 QO2020 c 48.50 QO2030 c 48.50 QO3020 c 48.50 QO3030 c 48.50 Two Single-pole Individual Trip 120/240 Vac 2 Spaces Required Catalog No. Price Order Two QO1515 or QO2020 circuit breakers and handle tie Cat. # QOTHT .... ... QO20303020 i $89.00 .... ... .... ... a 10–30 A circuit breakers are suitable for use with 60°C or 75°C conductors. 35–125 A circuit breakers are suitable for use with 75°C conductors. b UL Listed 5000 AIR on corner grounded Delta systems. c UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. d UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. e Requires four spaces (#1–300 kcmil Al/Cu). Not suitable for use in 3-phase panel. Use only in single phase panel rated 150 A or greater. f Order only. Contact your nearest Square D/Schneider Electric sales office. g UL Listed for use ahead of QO, QO-GFI, QO-EPD, QOT, and QO-PL 10,000 AIR circuit breakers to permit their application at 22,000 A fault level. h 100 A maximum branch mounted opposite. i Includes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT. Additional Infmation Accessories . . . . . . . . . . . .page 13 © 2004 Schneider Electric All Rights Reserved 6/7/04 DE2A Discount Schedule 3 LOAD CENTERS 10,000 AIR Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® Circuit Breakers Class 685, 690, 730, 912, 950 www.SquareD.com For the most up-to-date information Plug-On Circuit Breakers—UL Listed Amperes Interrupting Rating (AIR) In Amperes RMS Symmetrical LOAD CENTERS 1-pole QO-AFI Three-wire QO-SWN Two-wire QO-SWN 2-pole QO-GFI 1-pole QO-GFI QO 1-pole With Shunt Trip QO-K Key Operated QO-HM High magnetic trip circuit breakers are recommended for applications where high initial inrush may occur and for individual dimmer applications. Ampere Rating a 120 Vac—10,000 AIR 15 20 QO-AFI QO-HID QO-HID Circuit Breakers HID circuit breakers are for use on circuits feeding fluorescent and high intensity discharge (HID) lighting systems such as mercury vapor, metal halide, or high pressure sodium. These circuit breakers are physically interchangeable with QO circuit breakers. 1-pole Catalog No Price QO115HMcd QO120HMcd $20.40 20.40 Ampere Rating a 1-pole 120/240 Vac 15 20 25 30 40 50 10,000 AIR 1 Space Required Catalog No. Price QO115HIDc $25.40 QO120HIDc 25.40 QO125HID 25.40 QO130HID 25.40 QO140HID 25.40 QO150HID 25.40 QO Circuit Breakers with arc fault protection in accordance with UL1699. Ampere Rating a 15 20 1-pole 120 Vac 10,000 AIR 1 Space Required Catalog No. Price QO115AFId $160. QO120AFId 160. 1-pole 120 Vac 22,000 AIR 1 Space Required Catalog No. Price QO115VHAFId $331. QO120VHAFId 331. QO-K QO-GFI QWIK-GARD® circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more, for people protection. Do not connect to more than 250 feet of load conductor for the total one-way run to prevent nuisance tripping. QWIK-GARD Circuit Breakers With Ground Fault Circuit Interrupter 1-pole 2-pole Common Trip 120 Vac 120/240 Vac 10,000 AIR 22,000 AIR 10,000 AIR 1 Space Required 1 Space Required 2 Spaces Required Catalog No. Price Catalog No. Price Catalog No. Price QO115GFI $155. QO115VHGFI $321. QO215GFI $275. QO120GFI 155. QO120VHGFI 321. QO220GFI 275. QO125GFI 155. QO125VHGFI 321. QO225GFI 275. QO130GFI 155. QO130VHGFI 321. QO230GFI 275. .... ... .... ... QO240GFI 275. .... ... .... ... QO250GFI 275. .... ... .... ... QO260GFIb 275. Ampere Rating a 15 20 25 30 40 50 60 QO-EPD QO-EPD circuit breakers provide overload and short circuit protection combined with Class B ground fault protection. They are designed to provide ground fault protection of equipment at a 30 milliampere level. They are not designed to protect people from electrical shock. Ampere Rating a 15 20 25 30 40 50 60 1-pole 120 Vac 10,000 AIR 1 Space Required Catalog No. Price QO115EPD $273. QO120EPD 273. QO125EPD 273. QO130EPD 273. .... ... .... ... .... ... 2-pole Common Trip 120/240 Vac 10,000 AIR 2 Spaces Required Catalog No. Price QO215EPD $440. QO220EPD 440. QO225EPD 440. QO230EPD 440. QO240EPD 440. QO250EPD 440. QO260EPDb 440. QO-SWN Switch Neutral Common Trip 2002 NEC® 514.11 Ampere Rating a 10 15 20 25 30 40 50 4 2 Wire 120 Vac 10,000 AIR 2 Spaces Required Catalog No. Price QO210SWN $63. QO215SWN 63. QO220SWN 63. QO225SWN 63. QO230SWN 63. QO240SWN 63. QO250SWN 63. 3 Wire 120/240 Vac 10,000 AIR 3 Spaces Required Catalog No. Price QO310SWN $95. QO315SWN 95. QO320SWN 95. QO325SWN 95. QO330SWN 95. QO340SWN 95. QO350SWN 95. DE2A 2-pole Common Trip 120/240 Vac 10,000 AIR 2 Spaces Required Catalog No. Price QO215HID $58.00 QO220HID 58.00 QO225HID 58.00 QO230HID 58.00 QO240HID 58.00 QO250HID 58.00 3-pole Common Trip 240 Vac 10,000 AIR 3 Spaces Required Catalog No. Price QO315HID $200.00 QO320HID 200.00 QO325HID 200.00 QO330HID 200.00 .... ... .... ... Key operated QO circuit breakers are available in single-pole construction and can be mounted in any single-pole space which will accept a standard QO. These circuit breakers can be turned ON or OFF or to RESET with a special key (Catalog No. QOK10) included with the circuit breaker. These circuit breakers are UL Listed and available as shown in the table. 120 Vac—10,000 AIR (1 Space Required) Ampere Rating a 10 15 20 25 30 Catalog No. Price QO110K QO115K QO120K QO125K QO130K $109. 109. 109. 109. 109. a 10–30 ampere breakers are suitable for use with 60°C or 75°C conductors. 35–60 ampere circuit breakers are suitable for use with 75°C conductors. b Suitable only for feeding 240 Vac and 208 Vac 2 wire loads. Does not contain load neutral connection. c UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. d UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. Non-automatic (Standard) Miniature Switches Miniature non-automatic switches have the same physical packaging as miniature circuit breakers, but open only when the handle is switched to the OFF position. Non-automatic switches provide no overcurrent protection or short circuit protection. They must not be used on systems that have an available fault current greater than the values listed in the table. Non-automatic switches are UL Listed per UL 1087 and are CSA certified. Non-automatic Miniature Switches, 240 Vac 10 kA Ampere Rating 60 100 60 100 125 Discount Schedule 2-pole Catalog No. Price QO200 $ 46.90 QO2000 133.00 QOU200 58.00 QOU2000 164.00 QOU20001 302.00 3-pole Catalog No. Price QO300 $165.00 QO3000 244.00 QOU300 190.00 QOU3000 277.00 QOU30001 477.00 © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® Circuit Breaker Accessories Class 1130 www.SquareD.com For the most up-to-date information Accessories for Use with QO Miniature Circuit Breakers Catalog Number Converts any two adjacent 120/240 Vac single-pole QO breakers to independent trip 2-pole . . . . . . . . . . . . . . . . . . . . . . Converts any two adjacent 120/240 Vac single-pole side-by-side QOT breakers to independent trip 2-pole . . . . . . . . . . QO1HT QOTHT Handle Clamp: Clamp for holding QO single-pole handle in “ON’’ or “OFF’’ position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Clamp for holding QO or Q1 either 1, 2 or 3-pole breaker handles in “ON’’ or “OFF’’ position . . . . . . . . . . . . . . . . . . . . . . Handle Padlock Attachment: For padlocking single-pole QO breaker in “ON’’ or “OFF’’ position Loose attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fixed attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . For padlocking single-pole QO circuit breaker in “OFF’’ position only, fixed attachment. . . . . . . . . . . . . . . . . . . . . . . . . . . For padlocking single-pole side-by-side QOT breaker in “ON’’ or “OFF’’ position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . For 2 and 3-pole QO and Q1 breakers which require padlocking in either “ON’’ or “OFF’’ position. (Not GFI) Loose attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fixed attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . For padlocking 2 and 3-pole QO circuit breakers in “OFF’’ position only, fixed attachment. . . . . . . . . . . . . . . . . . . . . . . . For padlocking single-pole QO-GFI, QO-AFI and QO-EPD circuit breakers in “OFF’’ position only, fixed attachment. . For padlocking 2-pole QO-GFI in either “ON’’ or “OFF’’ position, fixed attachment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . For padlocking 2-pole QO-GFI and QO-EPD circuit breakers in “OFF’’ position only, fixed attachment. . . . . . . . . . . . . . SUB-FEED LUGS Price $ Schedule 2.50 2.50 DE2E DE2E QO1LO HLO1 2.50 6.60 DE2E DE2E QOHPL QO1PA QO1PAF QOTHPA 6.30 7.10 29.00 7.40 DE2E DE2E DE2E DE2E QO1HPL QO1PL QO2PAF QOGFI1PAF GFI2PA QOGFI2PAF 7.10 7.10 17.20 34.00 6.10 25.60 DE2E DE2E DE2E DE2E DE2A DE2E 60 ampere 2-pole plug-on – 2 spaces required (#6–2 Al/Cu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 ampere 2-pole plug-on – 2 spaces required (#12–2/0 Al/Cu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 ampere 2-pole plug-on – 4 spaces required (#4–300 Al/Cu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 ampere 3-pole plug-on – 3 spaces required (#12–2/0 Al/Cu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO60SL QO2125SL QO2225SLa QO3125SL 31.40 91.00 205.00 91.00 DE2A DE2A DE2A DE3 MECHANICAL INTERLOCK ATTACHMENT: For interlocking the handles of two 2-pole or one 2-pole and one 1-pole QO and Q1 breakers mounted side-by-side so that only one circuit breaker can be “ON’’ at a time (Not QOU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO2DTI 16.60 DE2E With Retaining Kit: QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual power supply applications. Can be used with (2) 2-poles or (1) 2-pole and (1) 1-pole QO circuit breakers in QO816L100 load centers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO2DTIM 42.00 DE2E LOAD CENTERS Description HANDLE ATTACHMENTS Handle Tie: QO1LO QO1PL QO1PA HLO1 QO1HT QO2DTI QO1HPL QOTHPA Factory-installed Accessories for Use with QO Miniature Circuit Breakers Factory-installed electrical accessories take up an additional pole space on QO®, QO-GFI, QO-EPD and QO-SWN circuit breakers. All AC electrical accessories shown below are rated for 50/60 Hz. Accessories are not available for QOB-VH (2-pole 150 A and 3-pole 110–150 A) circuit breakers or QO molded case switches and the 125, 150 or 200 A QO circuit breakers. QO circuit breakers will accept only one accessory per circuit breaker. Undervoltage trip is not available on miniature circuit breakers. Accessory SHUNT TRIP Description Trips the circuit breaker from a remote location by means of a trip coil energized from a separate circuit. A 120 Vac shunt trip will operate at 55% or more of rated voltage. All other shunt trips will operate at 75% or more of rated voltage. Rated Voltage AC/DC AC 12 24 120 208 240 Coil List Price Accessory Burden Suffix Adder 60 VA 168 VA 72 VA -1042 -1042 $126. 126. 228 VA 288 VA -1021 -1021 -1021 AUXILIARY Monitors circuit breaker contact status SWITCHES and provides a remote signal indicating the circuit breaker contacts are OPEN or CLOSED. Application Contact Max. Comb. Voltage Max. Load Price Suffix List Adder 1A 1B AC 120 AC 120 5A 5A -1200 -1201 $ 88. 88. 1A AC 120 5A -2100 88. • Auxiliary switch terminals accept (2) #14–#12 AWG Cu leads. • Leads (EH): Yellow for “A’’, Blue for “B’’, Striped common #18 AWG Cu. Application • For use with momentary or maintained push button. • Not available on QO-GFI, QO-EPD. • Shunt trip terminals accept (2) #14–#12 AWG Cu. Description ALARM Used with control circuits and is SWITCHES actuated only when the circuit breaker has tripped. Standard construction includes a normally-open contact. Application • Leads: Alarm switch terminals accept (2) #14–#12 AWG Cu leads. a Not suitable for use in 3-phase panels. Use only in single phase panel rated 150 A or greater. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE2 Discount Schedule 5 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® Load Centers Series Rating Class 1100 www.SquareD.com For the most up-to-date information The rating of the load center is equal to the lowest interrupting rating of any circuit breaker installed or combination series connected circuit breaker. Additional or replacement circuit breakers MUST have an interrupting and voltage rating equal to or greater than that of the circuit breaker with the lowest interrupting and voltage rating presently installed. See load center interior for circuit breaker types. Short Circuit Current Rating Maximum Short Circuit Current Rating (RMS Symmetrical) Load Center Voltage Rating 240 Vac Max. Systems Voltage LOAD CENTERS 5,000 10,000 22,000 42,000 65,000 Integral or Remote Square D Circuit Breaker or Remote Fuses Fuse Class Catalog Designation d Current Rating Amperes Max. Square D Branch Circuit Breaker Catalog Designation de Current Rating Amperes 1-pole 240 Vac, 3 Phase 3 Wire Grounded "B" phase. … … … QO-H … 120/240 Vac, 1 Phase 3 Wire … … … QO QOT 10–70 15–30 2-pole 3-pole 15–100 … 10–200c … … … 208Y/120 Vac, 3 Phase 4 Wire … … … QO 10–70 10–125c 10–100 240/120 Vac, 3 Phase 4 Wire Delta a … … … QO-H QO … 10–70 15–100 10–125c … 10–100 240 Vac, 3 Phase 3 wire Delta … … … QO-H QO … … 15–100 … … 10–100 120/240 Vac, 1 Phase 3 Wire … … … QO-VH 15–30 15–200c … 208Y/120 Vac, 3 Phase 4 Wire … … … QO-VH 15–30 15–125c 15–100 15–125c 15–100 240/120 Vac, 3 Phase 4 Wire Delta b … … … QO-VH 15–30 240 Vac, 3 Phase 3 wire Delta … … … QO-VH … 120/240 Vac, 1 Phase 3 Wire … … … QOH … 40–125c … 208Y/120 Vac, 3 Phase 4 Wire … … … QOH … 40–125c … 120/240 V ac, 1 Phase 3 Wire … … … QH 15–30 15–30 … 208Y/120 Vac, 3 Phase 4 Wire … … … QH 15–30 15–30 15–30 240/120 Vac, 3 Phase 4 Wire Delta b … … … QH 15–30 15–30 15–30 240 Vac, 3 Phase 3 wire Delta … … … QH … … 15–30 120/240 Vac, 1 Phase 3 Wire … QOM-VH 225 QO QOT 15–70 15–30 15–200c … … … 120/240 Vac, 1 Phase 3 Wire … QO-VH 200 QO QOT 15–70 15–30 15–200c … … … … 10–100 Series Combination Short Circuit Current Rating 22,000 25,000 42,000 65,000 100,000 208Y/120 Vac, 3 Phase 4 Wire … QO-VH 100 QO 15–70 15–100 15–100 240/120 Vac, 3 Phase 4 Wire Delta b … QO-VH 100 QO 15–70 15–100 15–100 240 Vac, 3 Phase 3 wire Delta … QO-VH 100 QO … … 15–100 120/240 Vac, 1 Phase 3 Wire … QD 225 QO QOT 15–70 15–30 15–200c … … … 208Y/120 Vac, 3 Phase 4 Wire … QD 225 QO QO-VH 15–70 15–30 15–125c 15–125c 15–30 15–100 240/120 Vac, 3 Phase 4 Wire Delta a … QD 225 QO-H QO QO-VH … 15–70 15–30 15–100 15–125c 15–125c … 15–30 15–100 240 Vac, 3 Phase 3 wire Delta … QD 225 QO-H QO QO-VH … … … 15–100 … … … 15–30 15–100 120/240 Vac, 1 Phase 3 Wire … QOH 125 QO QOT 15–70 15–30 15–100 … … … 120/240 Vac, 1 Phase 3 Wire … QG 225 QO QOT 15–70 15–30 15–200c … … … 208Y/120 Vac, 3 Phase 4 Wire … QG 225 QO QO-VH 15–70 15–30 15–125c 15–125c 15–30 15–100 240/120 Vac, 3 Phase 4 Wire Delta a … QG 225 QO-H QO QO-VH … 15–70 15–30 15–100 15–125c 15–125c … 15–30 15–100 240 Vac, 3 Phase 3 wire Delta … QG 225 QO-H QO QO-VH … … … 15–100 … … … 15–30 15–100 120/240 Vac, 1 Phase 3 Wire … … QJ 225 QO QOT 15–70 15–30 15–200c 208Y/120 Vac, 3 Phase 4 Wire … … QJ 225 QO QO-VH 15–70 15–30 15–125c 15–125c 15–30 15–100 120/240 Vac, 1 Phase 3 Wire T3 … 200 QO QOT 15–70 15–30 15–200c … … … 208Y/120 Vac, 3 Phase 4 Wire T3 … 200 QO 15–70 15–125c 15–100 240/120 Vac, 3 Phase 4 Wire Delta b T3 … 200 QO 15–70 15–125c 15–100 240 Vac, 3 Phase 3 wire Delta T3 … 200 QO … … 15–100 a 240 Vac 3 Phase 4 Wire Delta: When wired for Delta system, phase "B" must be 208 V to neutral. Two-pole circuit breakers connected to phase "B" must be rated 240 V (QO-H). Single-pole circuit breakers must not be connected to phase "B". b 240 Vac 3 Phase 4 Wire Delta: When wired for Delta system, phase "B" must be 208 V to neutral. For this Short Circuit Current Rating, single-pole and two-pole circuit breakers must not be connected to phase "B". c 100 amperes maximum branch circuit breaker in load centers with 125 A maximum mains rating. d See circuit breaker for voltage and interrupting rating. e QO includes suffixes: GFI, EPD, PL, AS and AFI. QO-VH includes suffixes GFI and AFI 6 © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® Load Centers Indoor—Single Phase, Main Lug Class 736, 1130 www.SquareD.com For the most up-to-date information Single Phase Three Wire—120/240 Vac—UL Listed Main Lugs (Order QO, QOT, QO-EPD, QO-GFI and QO-PL branch circuit breakers from pages 3 and 4) Mains Rating Spaces (A) Max. Max. Total Number Number Price Single of Tandem (Interior, Pole Circuit Box & Circuitsa Breakers Cover) Indoor Cover with Door (Order Separately) Load Center Box and Interior Catalog Number Flush Surface Catalog No. Catalog No. Price Main Wire Size AWG/kcmil Price Al Cu Equipment Ground Bar Kit (Order Separately) Catalog No. Price Box No. See Page 19 30 2 2 0 70 2 4 2 6 12 6 100 100 125 $ 27.80 QO2L30Scd $ 27.80 #12–10 #14–10 PK3GTA-1 45.70 QO24L70F/Sef 45.70 Cover Included—Without Door 58.00 QO612L100F/Se g 58.00 60.00 QO612L100DF/Segh 60.00 Cover Included—With Door 87.00 QO816L100F/Seg 87.00 Cover Included—Without Door 8 16 8 95.00 QO816L100DF/Segh 95.00 Cover Included—With Door 6 12 6 74.00 QO612L100DFCU/SCUeghi 74.00 Cover Included—With Door 8 16 8 116.00 QO816L100DFCU/SCUeghi 116.00 Cover Included—With Door 4 8 4 62.00 QO148L125GF/Sej 62.00 Cover Included—Without Door #12–3 #14–4 PK4GTA $ 7.60 1 7.20 2 #8–1 PK7GTA 7.80 4 #8–1 PK7GTA 7.80 4 #8–1 PK7GTA 7.80 4 #8–1 PK7GTA 7.80 4 #8–1 PK7GTA 7.80 #12–2/0 #14–2/0 PK7GTAm LOAD CENTERS Fixed Mains—Factory-installed Main Lugs—10,000 RMS Sym. Amperes Short Circuit Current Ratingb 4 21 Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratingb k QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus I N D O O R 125 12 12 12 24 0 12 $ 131.10 QO112L125G 157.10 QO11224L125G $106.00 132.00 QOC16UF QOC16UF QOC16US $ 25.10 QOC16US 25.10 PK9GTAm PK15GTAm 6 6 16 16 16 24 0 8 170.10 QO116L125G 200.10 QO11624L125G 145.00 175.00 QOC24UF QOC24UF QOC24US QOC24US 25.10 25.10 PK12GTAm PK15GTAm 7 7 20 20 24 32 20 24 24 32 0 4 0 0 181.10 247.10 254.10 289.40 156.00 222.00 229.00 263.00 QOC24UF QOC24UF QOC24UF QOC32UF QOC24US QOC24US QOC24US Use Flush 25.10 25.10 25.10 26.40 PK15GTAm PK15GTAm PK15GTAm PK23GTA & LK100ANm 7 7 7 8 QO120L125G QO12024L125G QO124L125G QO132L125G #6–2/0 Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratingbk QOM2 Main Frame Size—Convertible To Main Circuit Breaker—Copper Bus 150 20 24 30 30 24 30 10 0 0 200 12 24 30 30 40 12 36 30 40 40 0 12 0 10 0 225 42 42 0 $ 279.00 QO12030L150G 287.00 QO124L150G 291.00 QO130L150G 235.00 546.00 316.00 369.00 497.00 QO112L200G QO12436L200TFTl QO130L200G QO13040L200G QO140L200G 552.00 QO142L225G $221.00 229.00 233.00 QOC30UF QOC30UF QOC30UF QOC30US $ 58.00 QOC30US 58.00 QOC30US 58.00 #6–250 PK23GTA & LK100ANm PK15GTAm PK23GTA & LK100ANm 9 9 9 177.00 488.00 271.00 311.00 439.00 QOC30UF QOC40UF QOC30UF QOC30UF QOC40UF QOC30US QOC40US QOC30US QOC30US QOC40US 58.00 58.00 58.00 58.00 58.00 #6–250 PK15GTAm PK23GTA & LK100ANm PK23GTA & LK100ANm PK23GTA & LK100ANm PK23GTA & LK100ANm 9 10 9 9 10 478.00 QOC42UF QOC42US 74.00 #6–300 PK23GTA & LK100ANm 11 Fixed Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratingbk 400 400 400 12 30 42 12 30 42 0 QON12LS400(Int)n $1468.00 MH50 (Box) $ 971.00 MHC50QVF MHC50QVS $422.v 75.v 0 QON30LS400(Int) n 1547.00 MH50 (Box) 1050.00 MHC50QVF MHC50QVS 75.v 0 QON42LS400(Int) n 1641.00 MH53 (Box) 1125.00 MHC53QVF MHC53QVS 75.v Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers. b UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. c Will not accept QO-EPD or QWIK-GARD® QO-GFI circuit breakers. d Mains rated 25 A when Al wire is used. e Order F for flush device or S for surface device. f Use #10 maximum size wire for GFI circuit breaker. g 70 A Max. branch circuit breaker and 70 A max. back fed main circuit breaker. h No provisions for lock kits. i CU indicates copper bus. j Copper bus. k UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. l Supplied with feed-thru lugs. m Factory-included. n Interior only, order box separately. o PK27GTA includes a #6–2/0 Al/Cu lug. QO816L100F or S without cover DE3A PK27GTAo 422.v (1) #1/0–750 or (2) #1/0–300 or 441.v (1) #1/0–750 or (2) #1/0–300 PK15GTA-6 $22.50 15 15 35.50 17 Main Circuit Breaker Kits QOM1 Frame Size 50–125 Amperes QOM2 Frame Size 100–225 Amperes Field-installable Main Circuit Breaker (Convertible Load Centers Only) p Main Circuit Breaker Rating (A) Use With Convertible Load Center Mains Rating 22,000 AIR q Main Circuit Breaker Price Lug Wire Sizer AWG/kcmil Al or Cu QOM1 Frame Size 50 60 70 80 90 100 110 125 100–125 100–125 100–125 100–125 100–125 100–125 125 125 QOM50VH QOM60VH QOM70VH QOM80VH QOM90VH QOM100VH QOM110VH QOM125VH $ 93.00 93.00 93.00 134.00 134.00 134.00 312.00 312.00 #12–2/0 QOM2 Frame Sizes 100 125 150 175 200 225 150–225 150–225 150–225 200–225 200–225 225 QOM2100VH QOM2125VH QOM2150VH QOM2175VH QOM2200VH QOM2225VH 312.00 312.00 312.00 312.00 312.00 312.00 #4–300 p Do not exceed the load center mains rating. q 22,000 AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10,000 AIR branch circuit breakers to permit their application on systems with up to 22,000 amperes available fault current. r Wire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find out maximum wire size permitted in a particular load center per UL, see pages 7 thru 12 under Main Wire Size. s Add suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126.00. QO120L125G For additional information, reference Catalog #1100CT9901. © 2004 Schneider Electric All Rights Reserved 6/7/04 (1) #1/0–750 or (2) #1/0–300 v PE1A Discount Schedule 7 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® Load Centers Indoor—Single Phase, Main Circuit Breaker Class 1130 www.SquareD.com For the most up-to-date information Single Phase Three Wire—120/240 Vac—UL Listed Main Circuit Breaker (Order QO, QOT, QO-EPD, QO-GFI, QO-AFI and QO-PL branch circuit breakers from pages 3 and 4.) aMax. Max. Mains Number Number Total Price Rating Spaces Single of Tandem (Interior, Box & (A) Pole Circuit Cover) Circuits Breakers Indoor Cover with Door (Order Separately) Load Center Box and Interior Catalog Number Price Flush Catalog No. Surface Catalog No. Price Main Wire Size AWG/kcmil Al or Cu Equipment Ground Bar Kit (Order Separately) Catalog No. Price Box No. See Page 19 #6–1 PK9GTA PK12GTA PK15GTA $ 8.90 10.50 11.40 5 6 6 LOAD CENTERS Convertible Mains —Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating —Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 7) b QOM1 Main Circuit Breaker Frame Size—Copper Bus 100 125 I N D O O R 12 16 20 12 16 20 0 0 0 $ 226.10 253.10 289.10 QO112M100 QO116M100 QO120M100 $ 201. 228. 264. QOC12UF QOC20U100F QOC20U100F QOC12US QOC20U100S QOC20U100S 24 32 24 32 0 0 369.10 484.10 QO124M100 QO132M100 24 32 24 32 0 0 546.10 694.40 QO124M125 QO132M125 $ 25.10 25.10 25.10 344. 459. QOC24UF QOC32UF QOC24US Use Flush 25.10 25.10 #6–2/0 PK15GTA PK18GTA 11.40 12.50 7 8 521. 668. QOC24UF QOC32UF QOC24US Use Flush 25.10 26.40 #6–2/0 PK15GTA PK18GTA 11.40 12.50 7 8 #4–250 PK18GTA PK15GTA PK18GTA PK18GTA $12.50 11.40 12.50 12.50 9 9 9 10 PK23GTA PK15GTA PK18GTA PK23GTA PK23GTA PK23GTA 14.20 11.40 12.50 14.20 14.20 14.20 9 9 9 9 10 11 PK23GTA PK23GTA 14.20 14.20 11 11 $22.50 16 35.50 16 Convertible Mains —Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating —Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 7)b QOM2 Main Circuit Breaker Frame Size—Copper Bus 150 20 24 30 32 30 24 30 32 10 0 0 0 $ 547.00 566.00 569.00 646.00 QO12030M150 QO124M150 QO130M150 QO132M150 $ 489. 508. 511. 588. QOC30UF QOC30UF QOC30UF QOC40UF QOC30US QOC30US QOC30US QOC40US $ 58.00 58.00 58.00 58.00 200 20 24 30 30 40 42 40 24 30 40 40 42 20 0 0 10 0 0 547.00 577.00 586.00 638.00 747.00 813.00 QO12040M200 QO124M200 QO130M200 QO13040M200 QO140M200 QO142M200 489. 519. 528. 580. 689. 739. QOC30UF QOC30UF QOC30UF QOC30UF QOC40UF QOC42UF QOC30US QOC30US QOC30US QOC30US QOC40US QOC42US 58.00 58.00 58.00 58.00 58.00 74.00 225 40 42 40 42 0 0 797.00 835.00 QO140M225 QO142M225 723. 761. QOC42UF QOC42UF QOC42US QOC42US 74.00 74.00 #4–250 #4–300 Fixed Mains—Factory-installed LAL Main Circuit Breaker—42,000 Fully Rated RMS Sym. Amperes Maximum Short Circuit Current Ratingc 300 42 400 42 42 42 0 0 $4686.00 QON42MS300(Int)d MH68 (Box) $4107. 75.r 4686.00 QON42MS400(Int)d MH68 (Box) 4107. 75.r MHC68VF MHC68VF MHC68VS MHC68VS $504.r (1) #4–500 or (2) #4–3/0 #4–600 504.r or(1) (2) #4–250 PK27GTAe or PK15GTA-6 Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers. b 22,000 AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10,000 AIR branch circuit breakers to permit their application on systems with up to 22,000 amperes available fault current. c UL short circuit current rating depends on lowest interrupting rating of circuit breakers installed. Also, UL Listed 5000 A short circuit current for corner grounded Delta systems. Use QO-H circuit breakers only. d Interior only, order box separately. e PK27GTA includes a #6–2/0 Al/Cu lug. Main Lug Kits QOL125 QOL225 Field-installable Main Lugs (Convertible Load Centers Only) Main Lug f Ampere Rating Use On Convertible Load Center With Mains Rating Catalog Number Price 125 100–125 QOL125h $29.40 #6–2/0 225 150–225 QOL225h 69.00 #6–300 Lug Wire Size g AWG/kcmil Al or Cu f Do not exceed the load center mains rating. g Wire range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size permitted in a particular load center per UL, see pages 7 thru 12 under main wire size. h If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from page 14. QO130M150 For additional information, reference Catalog #1100CT9901. 8 DE3A rPE1A Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® Load Centers Rainproof—Single Phase, Main Lugs, Main Circuit Breaker Class 1130 www.SquareD.com For the most up-to-date information Single Phase Three Wire—120/240 Vac—UL Listed Main Lugs (Order QO, QOT, QO-GFI, QO-EPD, QO-AFI and QO-PL branch circuit breakers from pages 3 and 4.) Mains Rating (A) Max. Number Single Pole Circuitsa Spaces Max. Number of Tandem Circuit Breakers Total Price (Interior, Box and Cover) Main Wire Size AWG/kcmil Load Center Box and Interior Catalog Number Price Equipment Ground Bar Kit (Order Separately) Al Cu Catalog No. #14–4 #14–4 Price Box No. See page 20 Non-Metallic Enclosure Fixed Mains—Factory-installed Main Lugs—10,000 RMS Sym. Amperes Short Circuit Current Rating 60 2 4 2 $ 68.00 QO24L60NRNM $ 68.00 Factory-incl. 1NM LOAD CENTERS Metallic Enclosure Fixed Mains—Factory-installed Main Lugs—10,000 RMS Sym. Amperes Short Circuit Current Rating R A I N P R O O F 40 2 2 0 $ 75.00 70 2 4 2 87.00 QO2L40RBb 100 6 6 8 12 12 16 6 6 8 95.00 105.00 154.00 QO612L100RBc QO612L100TRBc QO816L100RBc 95.00 105.00 154.00 100 6 8 12 16 6 8 116.00 186.00 QO612L100RBCUcd QO816L100RBCUcd 116.00 186.00 125 4 8 4 101.00 QO148L125GRBd 101.00 QO24L70RBb $ 75.00 #12–6 #14–6 PK3GTA-1 $ 7.60 1R 87.00 #12–3 #14–4 PK4GTA 7.20 1R #8–1 PK7GTA Factory-installed PK7GTA 7.80 ... 7.80 2R 2R 2R #8–1 PK7GTA PK7GTA 7.80 7.80 2R 2R #12–2/0 #14–2/0 PK7GTA Factory-incl. 15R Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Maximum Short Circuit Currente f g QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus 125 12 12 16 24 12 24 24 24 0 12 8 0 $190.00 243.00 290.00 348.00 QO112L125GRB QO11224L125GRB QO11624L125GRB QO124L125GRB $190.00 243.00 290.00 348.00 #6–2/0 PK9GTA Factory-incl. PK15GTA Factory-incl. PK15GTA Factory-incl. PK15GTA Factory-incl. 3R 3R 4R 4R Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Maximum Short Circuit Current e f g QOM2 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus 150 30 30 0 $391.00 #6–250 PK23GTA & LK100AN Factory-incl. 6R 200 12 30 30 40 12 30 40 40 0 0 10 0 320.00 444.00 476.00 647.00 QO130L150GRB QO112L200GRB QO130L200GRB QO13040L200GRB QO140L200GRB $391.00 320.00 444.00 476.00 647.00 #6–250 PK9GTA Factory-incl. PK23GTA & LK100AN Factory-incl. PK23GTA & LK100AN Factory-incl. PK23GTA & LK100AN Factory-incl. 5R 6R 6R 7R 225 42 42 0 873.00 QO142L225GRB 873.00 #6–300 PK23GTA & LK100AN Factory-incl. 8R Single Phase Three Wire—120/240 Vac—UL Listed Main Circuit Breaker Order QO, QOT, QO-GFI, QO-EPD and QO-PL branch circuit breakers from pages 3 and 4. Mains Rating (A) Spaces a Max. Number Single Pole Circuits Max. Number of Tandem Circuit Breakers Total Price (Interior, Box and Cover) Load Center Box and Interior Catalog Number Price Main Wire Size AWG/kcmil Al or Cu Equipment Ground Bar Kit (Order Separately) Catalog No. Price Box No. See page 20 Convertible Mains —Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating —Convertible to Main Lugs (see page 8) or Lower Amperage Main Circuit Breaker (see page 7)hg QOM1 Main Circuit Breaker Frame Size—Copper Bus R A I N P R O O F 100 12 16 20 12 16 20 0 0 0 $307. 336. 368. QO112M100RB QO116M100RB QO120M100RB $307. 336. 368. #6–2/0 PK9GTA PK12GTA PK15GTA $ 8.90 10.50 11.40 3R 4R 4R 125 24 24 0 636. QO124M125RB 636. #6–2/0 PK15GTA 11.40 4R Convertible Mains —Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating —Convertible to Main Lugs (see page 8) or Lower Amperage Main Circuit Breaker (see page 7)hg QOM2 Main Circuit Breaker Frame Size—Copper Bus 150 20 30 30 30 10 0 $635. 748. QO12030M150RB QO130M150RB $635. 748. #4–250 PK18GTA PK18GTA $12.50 12.50 5R 6R 200 20 30 40 40 30 40 20 0 0 636. 769. 931. QO12040M200RB QO130M200RB QO140M200RB 636. 769. 931. #4–250 PK23GTA PK18GTA PK23GTA 14.20 12.50 14.20 5R 6R 7R Feed Thru Main Circuit Breaker With Feed-Thru Lugs—Copper Bus—22,000 RMS Sym. Amperes Short Circuit Current Ratingh 125 6 12 6 $413. QO1612M125FTRB $413. #4–2/0 PK12GTA $10.50 3R 150 8 16 8 575. QO1816M150FTRB 575. #4–250 PK15GTA-L 23.30 6R 200 8 16 8 575. QO1816M200FTRB 575. #4–250 PK15GTA-L 23.30 6R Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers. b Use #10 maximum size wire for GFI circuit breaker. c 70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker. d Copper bus. e UL short circuit current rating depends on lowest interrupting rating of circuit breakers installed. f UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. g Side hinge door device; allow 11⁄4" on left side for door to open. h 22,000 AIR main circuit breaker UL Listed for use ahead of QO, QOT, QO-GFI, QO-EPD and QOPL 10,000 AIR branch circuit breakers to permit their application on systems up to 22,000 A available fault current. For additional information, reference Catalog #1100CT9901. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE3A Discount Schedule 9 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® Load Centers Three Phase—Main Lugs, Main Circuit Breaker Class 1130 Three Phase Mains Rating (A) www.SquareD.com For the most up-to-date information (Order QO, QO-GFI, QO-AFI, QO-PL branch circuit breakers from pages 3 and 4.) 3 Phase 4 Wire 208Y/120 Vac, 3 Phase 4 Wire 240/120 Vac Delta and 3 Phase 3 Wire 240 Vac Delta—UL Listed. Max. Number of 1-pole QO Breakers Total Price (Interior, Box and Cover) Indoor Cover with Door (Order Separately) Load Center Box and Interior Catalog Number Price Flush Catalog No. Surface Catalog No. Main Wire Size AWG/kcmil Price Al Equipment Ground Bar Kit (Order Separately) Cu Catalog No. Priceu Box No. See Pages 19, 20 LOAD CENTERS Fixed Mains—Factory-installed Main Lugs—Copper Bus—65,000 RMS Symmetrical Amperes Short Circuit Current Rating a 60 3 125 12 20 24 $ 246.10 339.10 385.10 71.00 QO312L125G QO320L125G QO324L125G QO403L60NF/S $ 221.00 314.00 360.00 71.00 QOC16UF QOC24UF QOC24UF Cover Included With Load Center QOC16US QOC24US QOC24US $ 25.10 u 25.10 u 25.10 u ... 200 18 353.00 QO318L200G 295.00 QOC30UF QOC30US 58.00 u #10–6 PK4GTA $ 7.20 13 #6–2/0 #6–2/0 Factory-incl.g Factory-incl.g Factory-incl.g ... ... ... 6 7 7 #6–250 #6–250 Factory-incl.f ... 9 9 30 471.00 QO330L200G 413.00 QOC30UF QOC30US 58.00 u Factory-incl.f ... I 225 42 635.00 QO342L225G 561.00 QOC42UF QOC42US 74.00 u #6–300 #6–300 Factory-incl.f ... N D O Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25,000 RMS Symmetrical Amperes Maximum O Short Circuit Current Rating b 100 27 $ 705.00 QO327M100 c $ 647.00 QOC30UF QOC30US $ 58.00 u #4–2/0 #4–2/0 PK15GTA $11.40 R 11 9 125 30 1287.00 QO330MQ125 d 1226.00 QOC342MQF QOC342MQS 61.00 #4–300 #4–300 PK18GTA 12.50 12 150 30 42 1287.00 1412.00 QO330MQ150d QO342MQ150d 1226.00 1351.00 QOC342MQF QOC342MQF QOC342MQS QOC342MQS 61.00 61.00 #4–300 #4–300 PK18GTA PK23GTA 12.50 14.20 12 12 200 30 42 1287.00 1412.00 QO330MQ200d QO342MQ200d 1226.00 1351.00 QOC342MQF QOC342MQF QOC342MQS QOC342MQS 61.00 61.00 #4–300 #4–300 PK18GTA PK23GTA 12.50 14.20 12 12 225 42 1412.00 QO342MQ225d 1351.00 QOC342MQF QOC342MQS 61.00 #4–300 #4–300 PK23GTA 14.20 12 Fixed Mains—Factory-installed Main Lugs—Copper Bus—65,000 RMS Symmetrical Amperes Short Circuit Current Rating a e 60 3 $ 118.00 125 12 20 323.00 419.00 QO403L60NRB QO312L125GRB QO320L125GRB $ 118.00 323.00 419.00 ... #10–6 PK4GTA #6–2/0 #6–2/0 Factory Incl.g Factory Incl.g $ 7.20 10R ... ... 3R 4R Cover Included R 18 412.00 QO318L200GRB 412.00 Factory Incl.f ... 200 #6–250 #6–250 A 30 559.00 QO330L200GRB 559.00 Factory Incl.f ... I 225 42 996.00 QO342L225GRB 996.00 #6–300 #6–300 Factory Incl.f ... N P Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25,000 RMS Symmetrical Amperes Maximum R Short Circuit Current Rating be O 100 27 $ 790.00 QO327M100RB c $ 790.00 #4–2/0 #4–2/0 PK15GTA $11.40 O 125 30 1431.00 QO330MQ125RB d 1431.00 #4–300 #4–300 PK18GTA 12.50 F 150 30 1431.00 QO330MQ150RBd 1431.00 200 30 42 1431.00 QO330MQ200RB d 1555.00 QO342MQ200RBd 1431.00 1555.00 225 42 1555.00 QO342MQ225RBd 1555.00 Cover Included #4–300 6R 6R 8R 6R 14R #4–300 PK18GTA 12.50 14R #4–300 #4–300 PK18GTA PK23GTA 12.50 14.20 14R 14R #4–300 #4–300 PK23GTA 14.20 14R Above listings thru 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2. a UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. b 25,000 RMS symmetrical amperes short circuit current rating maximum with Square D Type QDL main circuit breaker, or 22,000 RMS symmetrical amperes SCCR maximum with back-fed Type QO-VH main circuit breaker, feeding QO 10,000 AIR branch circuit breakers. c Includes factory-installed back fed QO3100VH main circuit breaker. d 65,000 RMS Symmetrical Amperes Short Circuit Current Rating maximum with field-installed Square D type QGL 65,000 AIR minimum main circuit breaker feeding QO and Q1 10,000 AIR minimum branch circuit breakers. e Side hinge door device allow 11⁄4" on left side for door to open. f PK23GTA and LK100AN. g PK15GTA. Three Phase Main Circuit Breakers Field-installable alternate main circuit breakers for QO three phase main circuit breaker load centers rated 70–225 A. Do not exceed the load center main rating. Amperage 70 80 90 100 110 125 150 175 200 225 Price 25k AIR QDL32070 QDL32080 QDL32090 QDL32100 QDL32110 QDL32125 QDL32150 QDL32175 QDL32200 QDL32225 $1189.00s 65k AIR QGL32070 QGL32080 QGL32090 QGL32100 QGL32110 QGL32125 QGL32150 QGL32175 QGL32200 QGL32225 $1628.00s 100k AIRh QJL32070 QJL32080 QJL32090 QJL32100 QJL32110 QJL32125 QJL32150 QJL32175 QJL32200 QJL32225 $1864.00s h When these 3-pole circuit breakers are used as the main circuit breaker of a three-phase load center, the maximum AIR rating is 65,000 at 240 Vac and 100,000 at 208 Vac. Three Phase Main Lug Kits Field-installable main lugs for convertible three phase main circuit breaker load centers. Main Lug Amperage Rating 125 225 Catalog Number Price QOL3125 QOL3225 $ 44.90 105.00 Lug Wire Size AWG/kcmil #6–2/0 Cu/Al #6–300 Cu/Al QO342MQ200 QO312L125G For additional information, reference Catalog #1100CT9901. 10 DE3 uDE3A sDE2 Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® Load Centers Special Applications Class 1130 www.SquareD.com For the most up-to-date information Order QO, QOT, QO-EPD, QO-GFI and QO-AFI Branch Circuit Breakers from pages 3 and 4. Spaces Max. Number Single Pole Circuitsa Manufactured Housing 30 c 50 2 2 Max. Number of Tandem Circuit Breakers Equipment Ground Bar Kit (Order Separately) Load Centerb Box , Interior, and Cover Catalog Number Price 1 Phase—2 Wire 120 Vac—Main Lugs Only—CSA Certified 10,000 RMS Sym. Ampere Short Circuit Current Rating 2 0 QO2L30TTSd 4 2 QO24L50TTSe $ Catalog No. 33.90 52.00 Price Factory-installed Main Wire Size AWG/kcmil Al Cu #12–10 ... #14–10 #14–6 1 Phase—2 Wire 120 Vac—Main Circuit Breaker—CSA Certified—10,000 RMS Sym. Ampere Short Circuit Current Rating 30 3 5 2 QO35FM30TTF/S $ 55.00 Factory-installed 1 Phase—3 Wire 120/240 Vac—Main Lugs Only—CSA Certified—10,000 RMS Sym. Ampere Short Circuit Current Rating 70 2 4 2 QO24L70TSe $ 52.00 6 12 6 QO612L100TF/Sg 57.00 Factory 6 12 6 QO612L100DTF/Sg 67.00 Installed 100 8 16 8 QO816L100TF/Sg 91.00 8 16 8 QO816L100DTF/Sg 106.00 Generator Panel 30 60 4 4 1 2 f 3 #12–3 #14–4 2 4 4 4 4 #14–8 #8–2 4 4 #4–1 1 Phase—3 Wire 120/240 Vac—Factory-installed Main Circuit Breakers with Mechanical Interlock 10,000 RMS Sym. Amperes Short Circuit Current Rating 8 4 QO48M30DSGP $375.00 PK7GTA 8 4 QO48M60DSGP 375.00 PK7GTA Phase—3 Wire 120/240 Vac—UL Listed I Load Center with Cover 1Complete QO Load Center—Box, Interior & Combination Cover—in One Package N Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratinghi D Convertible QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 7)—Copper Bus O 12 12 0 QO112L125GC $125.00 O 12 12 QO11224L125GC 166.00 125 A 24 R 20 0 QO120L125GC 189.00 20 Box No. See page 19 $7.80 7.80 PK12GTA Incl. PK15GTA Incl. PK15GTA Incl. #14–8 #8–2 #6–2/0 #6–2/0 #6–2/0 6 6 7 Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratinghi QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 7)—Copper Bus 150 A 30 30 0 QO130L150TC $301.00 PK23GTA & LK100AN Installed 200 A 30 40 10 QO13040L200GC 383.00 PK23GTA & LK100AN Incl. #6–250 #6–250 9 9 Convertible Mains—Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating QOM1 Main Frame Size—Convertible to Main Lugs (See page 8 or Lower Amperage Main Circuit Breaker (See page 7)—Copper Busj 12 12 0 QO112M100C $234.00 PK9GTA $ 8.90 12 8 QO11220M100C 275.00 PK15GTA 11.40 20 100 A 16 0 QO116M100C 263.00 PK12GTA 10.50 16 20 0 QO120M100C 297.00 PK15GTA 11.40 20 #4–1/0 #4–1/0 #4–1/0 #4–1/0 5 5 6 6 Convertible Mains—Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating QOM2 Main Frame Size—Convertible to Main Lugs (See page 8 or Lower Amperage Main Circuit Breaker (See page 7)—Copper Busj 20 30 10 QO12030M150C $562.00 PK18GTA $12.50 150 A 30 30 0 QO130M150C 580.00 PK18GTA 12.50 20 40 20 QO12040M200C 562.00 PK23GTA 14.20 30 30 0 QO130M200C 597.00 PK18GTA 12.50 200 A 30 40 10 QO13040M200C 649.00 PK23GTA 14.20 40 40 0 QO140M200C 758.00 PK23GTA 14.20 #4–250 #4–250 #4–250 #4–250 #4–250 #4–250 9 9 9 9 9 10 LOAD CENTERS Mains Rating (A) Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers. b Order F for flush device or S for surface device. c Mains rating 25 A when Al wire is used. d Will not accept QWIK-GARD® QO-GFI circuit breaker. Auxiliary Gutter e Use #10 maximum size wire for GFI circuit breakers. UL Listed For Use With Standard 1Ø an 3Ø Load Centers For Riser Applications k. For Auxiliary Gutter-Load f Main circuit breaker is a field-installed standard QO single pole circuit Center Compatibility, see Catalog 1100CT9901. breaker. Order separately from page 3. g 70 A max. branch circuit breaker and 70 A max. back fed main circuit Catalog Conduit Price Cover Width Height Depth breaker. Number Riser Size h UL short circuit current rating depends on lowest interrupting rating of 3⁄4, 2, 21⁄2 or l 3 13.50 26.12 3.75 SDAG26 $225. Flush 1 circuit breaker installed. i UL Listed 5000 A short circuit current rating for corner grounded Delta k One tap kit required for each riser wire. systems. Use QO-H circuit breakers only. l When used with B300 bolt-on hubs. j 22,000 AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10,000 AIR branch circuit breakers to permit their application on systems with up to 22,000 A available fault current. Tap Kits 120/240 Vac—UL Listed For Use With Auxiliary Gutters SDAG26 Accessories Catalog Number Price Use With Auxiliary Gutter Catalog Number SDGT30020 $54.00 SDAG26 SDGT300300 80.00 SDAG26 SDGT300C10C 33.10 SDAG26 SDGT300C300C 46.90 SDAG26 QOGL20 Grounding Terminals 27.10 SDAG26 Riser Wire Lug Type Mechanical (Included) Mechanical (Included) Anderson #VCEL030516H1 (Not included) Anderson #VCEL030516H1 (Not included) Mechanical (Included) Al/Cu Wire Size Tap Off Wire Lug Type Al/Cu Wire Size Mechanical (1) #6–2/0 (Included) Mechanical (2) #6–300 kcmil (1) #6–300 kcmil (Included) Anderson (2) #4–300 kcmil #VCEL02114S1 (1) #8–1/0 (Not Included) Anderson (2) #4–300 kcmil #VCEL030516H1 (1) #4–300 kcmil (Not included) (2) #6–300 kcmil (2) #6–2/0 ... ... For additional information, reference Catalog #1100CT9901. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE3A Discount Schedule 11 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® & HOMELINE® Load Centers Special Applications Class 1130, 1170 www.SquareD.com For the most up-to-date information Load Center Value Pack Spaces 1 Phase, 3 Wire—120/240 Vac—UL Listed—Convertible Mains—Factory-installed Main Circuit Breaker Complete Load Center (Box, Interior and Cover) and Selected Branch Circuit Breakers Mains Rating (A) Max. Max. Number Number Single of Tandem Pole Circuit Circuitsa Breakers Catalog No. Load Center Box , Interior, Cover and Branch Circuit Breakers Included Load Center/Circuit Breakers Price Equipment Box No. Main Ground Bar Kit See Wire Size (Order Separately) AWG/kcmil Pages 19, Al/Cu Catalog No. Price 20 LOAD CENTERS QO—Copper Bus—Order extra QO, QOT, QO-EPD, QO-GFI, QO-AFI branch circuit breakers from pages 3 and 4. 200 30 40 10 QOVP1 (1) QO13040M200C, (5) QO120 100 32 32 0 QOVP2 (1) QO132M100C, (5) QO120 $735.00 PK23GTA $14.20 #4–250 9 559.00 PK18GTA 12.50 #4–2/0 8 HOMELINE—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 15. I N D O O R 200 30 40 10 HOMVP1 (1) HOM3040M200TC, (5) HOM120, (1) HOM230 722.00 Included ... #4–250 10 200 30 40 10 HOMVP2 (1) HOM3040M200TC, (5) HOM115, (1) HOM230 722.00 Included ... #4–250 10 100 20 20 0 HOMVP4 (1) HOM20M100C, (5) HOM115 352.00 PK15GTA 11.40 #4–2/0 8 100 20 20 0 HOMVP5 (1) HOM20M100C, (5) HOM120 352.00 PK15GTA 11.40 #4–2/0 8 150 30 30 0 HOMVP12 (1) HOM30M150C, (5) HOM120, (1) HOM230 655.00 PK23GTA 14.20 #4–250 10 200 30 40 10 HOMVP9 (1) HOM3040M200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 885.00 Included ... #4–250 10 200 30 40 10 HOMVP14 (1) HOM3040M200TC, (12) HOM120, (1) HOM230, (1) HOM250 885.00 Included ... #4–250 10 200 30 40 10 HOMVPL1 (1) HOM3040L200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 641.00 Included ... #4–250 10 125 12 24 12 HOMVPL2 (1) HOM1224L125TC, (5) HOM120 235.00 Included ... #6–2/0 6 20 HOMVPRB1 (1) HOM2040M200RB, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 835.00 PK23GTA 14.20 #4–250 6R HOMELINE—Rainproof 200 20 40 Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers. Riser 1 Phase—2 Wire 120/240 Vac—Offset Interior Wide Gutter—50 A Maximum Branch Circuit Breakerbc Mains Rating (A) I N D O O R Spaces Max. Number Single Pole Circuitsa Max. Number of Tandem Circuit Breakers Load Center Box and Interior Catalog Number Equipment Ground Bar Kit (Order Separately) Load Center Cover Price Catalog Number Price Catalog No. Price Main Wire Size AWG/kcmil Al Cu Box No. See page 19 Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Rating QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 7)—Copper Bus 125 125 12 20 24 30 12 10 QO11224L125WG QO12030L125WG $225. 310. QOC20UFWG QOC20UFWG $35. 35. PK15GTA PK15GTA $11.40 11.40 #6–2/0 #6–2/0 14 14 PK23GTA 14.20 #4–250 23 Fixed Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Rating Copper Bus 200 30 40 10 QO13040L200WG 467. QOC30UFWG 68. Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers. b UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed. c UL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only. Panelboard-style Covers for Riser Panels Mono-Flat® Front available for riser panels as an alternative to standard load center cover listed above. Provides a low-profile, aesthetically pleasing solution for high-traffic areas in upscale multi-family applications. Deadfront included. Lock kit not provided. d Mains Rating of Load Center (A) Catalog Number Price 125 NQC20FWG $ 78. 200 NQC30FWG 120. d Order catalog number PK4FL for field installable lock kit. For additional information, reference Catalog #1100CT9901. 12 DE3A Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® Load Centers Accessories Class 1130 www.SquareD.com For the most up-to-date information QO Load Center Accessories Manual Transfer Equipment Kit Catalog Number Price Schedule Secures circuit breaker to interior when used as a back-fed main. For QO612L100F/S, RB, QO612L100DF/S, QO816L100F/S, RB, QO816L100DF/S and QO148L125GF/S, GRB load centers . . . . . . . . . . . . . . PK2MB 4.80 DE3A Secures circuit breaker to interior when used as a back-fed main. For 3Ø Load Centers . . . . . . . . . . . . . . . . . . . . . . . . . PK3MB 9.80 DE3A Secures circuit breaker to interior when used as a back-fed main for 2-pole QO 150–200 A circuit breakers. . . . . . . . . . PK5RK 9.80 DE3A Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main. PK4MB2LA For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.80 DE3A Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main. PK4MB2HA For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.80 DE3A For interlocking the handles of two 2-pole or one 2-pole and one 1-pole QO and Q1 circuit breakers mounted side-by-side so that only one circuit breaker can be “ON’’ at a time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO2DTI 16.60 DE2E QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit breakers in dual power supply applications. Can be used with (2) 2-poles or (1) 2-pole and (1) 1-pole QO circuit breakers in QO816L100 load centers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO2DTIM 42.00 DE2E Secures TWO 2-pole circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. . . . . . PK4DTIM4LA 68.00 DE3A Secures TWO 2-pole circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for back-up power supply applications. For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. . . . . . PK4DTIM4HA 68.00 DE3A Secures TWO 2-pole circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for back-up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. . . . . . PK4DTIM4LAL 68.00 DE3A For use on “G” and “S” Series NEMA 1 and “G” and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2-pole main circuit breaker of a load center (150–225 A) with a QO 2-pole (15–125 A) branch circuit breaker. Includes a retaining kit. QOCGK2 70.00 DE3A For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2-pole main circuit breaker of a load center (150–225 A) with a QO 2-pole (15–125 A) branch circuit breaker. Includes a retaining kit.. . . . . . . . . . . . . . . . . . . . . . . . . QORBGK2 70.00 DE3A Miscellaneous Cover Sealing Strap: Provides means of sealing trim mounting screws on QO load center covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO1SE 2.40 DE3A Surge Arresters: For use on 1Ø3W, 150 Vac maximum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . For use on 3Ø4W, 650 Vac maximum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SDSA1175 SDSA3650 61.00 165.00 DE1B DE1B QO SURGEBREAKER CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. HOMELINE SURGEBREAKER CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. QO2175SB HOM2175SB 106.00 106.00 DE1B DE1B UL Listed for mounting SDSA1175 surge arrester into ground bar mounting holes on 1Ø convertible main circuit breaker load centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QOSAMK 7.60 DE3A Generator Circuit Breaker Interlock Kit Surge Arrester Mounting Kit: PK2MB QOSAMK QO2DTI PK3MB QO2DTI Installed ON 1 OFF OFF 6 ON 4 3 2 ON OFF 5 ON OFF PK4DTIM4HA © 2004 Schneider Electric All Rights Reserved 6/7/04 QOCGK2 Installed 13 LOAD CENTERS Description Retaining Kit Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® and HOMELINE® Load Centers Accessories Class 1130, 6610 www.SquareD.com For the most up-to-date information QO Load Center Accessories Description LOAD CENTERS Price Schedule Filler Plates Fills opening in covers if twistout is removed in error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fills main circuit breaker opening in convertible load center covers. . . . . . . . . . . . 100–125 A. . . . . . . . . . . . . . . . . . . . . . . Fills main circuit breaker opening in convertible load center covers. . . . . . . . . . . . 150–225 A. . . . . . . . . . . . . . . . . . . . . . . Fills main circuit breaker opening in three phase load center covers (S01 and S02 Series). . . . . . . . . . . . . . . . . . . . . . . . Fills main circuit breaker opening in “Q” style three phase load center covers (S03 Series). . . . . . . . . . . . . . . . . . . . . . . . QOFP QOM1FP QOM2FP KFP Q2FP $ 2.40 13.50 13.50 13.50 13.50 DE3A DE3A DE3A DE3A DE3A Lock Kits Use with convertible mains, 1Ø and 3Ø 100–225 A, and fixed mains, 3Ø 125–225 A indoor load centers . . . . . . . . . . . Use with 300 and 400 ampere indoor load centers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PK6FLa PK4FL 62.00 60.00 DE3A PE1A Neutral / Ground Lugs Field-installed for #12 to 2 Al or #14 to 4 Cu wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Field-installed for #6 to 2/0 Al/Cu wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Field-installed for #14 to 2/0 Al/Cu wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Field-installed for #2 to 3/0 Al/Cu wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Field-installed for #4 to 300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center . . . . . . . . . . . . . . . . LK70AN LK100AN LK125AN LK150AN LK225AN 6.70 7.20 14.70 21.60 22.10 DE3A DE3A DE3A DE3A DE3A Ground Bar Kits Standard PK15GTA with a #1 to 4/0 Al/Cu Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard PK18GTA with a #1 to 4/0 Al/Cu Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard PK23GTA with a #1 to 4/0 Al/Cu Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PK15GTAL PK18GTAL PK23GTAL 23.30 25.20 27.10 DE3A DE3A DE3A Insulator Kit for PK7GTA thru PK27GTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PKGTAB 29.20 DE3A For padlocking main circuit breakers in convertible load centers, “OFF’’ . . . . . . . . 50–125 A, QOM1 Frame Size . . . . . 100–225 A, QOM2 Frame Size . . . . . QOM1PA QOM2PA 7.30 7.30 DE2E DE2E Handle Padlock Attachment: Catalog Number a QO612L100DF/S, QO816L100DF/S, QO612L100DFCU/SCU, QO816L100DFCU/SCU and QO403L60NF/S DO NOT have provisions for field-installed lock. QOFP PKGTAB PK6FL PK4FL HOMELINE Load Center Accessories Description Catalog Number Price Schedule $ 7.30 7.30 DE2E DE2E HOMFP 2.10 DE3C QOM1FP QOM2FP 13.50 13.50 DE3A DE3A Field-installed for #14 to 2 Al or #14 to 4 Cu wire Field-installed for #6 to 2/0 Al/Cu wire Field-installed for #14 to 2/0 Al/Cu wire Field-installed for #4 to 300 kcmil Al/Cu wire. Use in SeriesS, 150–225 A QO or HOM load center LK70AN LK100AN LK125AN LK225AN 6.70 7.20 14.70 22.10 DE3B DE3B DE3B DE3A Secures circuit breaker to interior when used as a back-fed main. For HOM612L100F/S, RB and HOM48L125GC, GRB load centers. HOM1RK 4.30 DE3C Secures ONE circuit breaker right side of interior when used as a back-fed main. For 100–125 ampere convertible main HOM4RK2LA load centers, Series S01 and S02 9.80 DE3C Secures ONE circuit breaker right side of interior when used as a back-fed main. For 150–225 ampere convertible main HOM4RK2HA load centers, Series S01 and S02 9.80 DE3C Handle Padlock Attachment: For padlocking main circuit breakers in convertible load center, “OFF” Filler Plates Fills opening in covers if twistout is removed in error Fills main circuit breaker opening in convertible load centers Neutral Lugs 50–125 A 100–225 A 100–125 A 150–225 A QOM1PA QOM2PA Miscellaneous Retaining Kit: Secures circuit breaker to interior when used as a back-fed main for 2-pole 150–200 ampere circuit breakers HOM5RK 9.80 DE3C Lock Kit: Use with convertible indoor load center covers(Series S-1) PK6FL 62.00 DE3A Generator Circuit Breaker Interlock Kit For use on “S” Series NEMA 1 and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2-pole main circuit breaker of a load center (150–225 A) with a HOMELINE 2-pole 15–125 A) branch circuit breaker. HOMCGK2 70.00 DE3D For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2-pole main circuit breaker of a load center (150–225 A) with a HOMELINE 2-pole (15–125 A) branch circuit breaker. HOMRBGK2 70.00 DE3D Voltage Testers Solenoid Type with polarity indication and slotted receptacles for holding prods. UL and CSA Listed. Description The Voltage Tester 120-240-480-600 Vac 50/60 Hz; 120-240-600 Vdc Type 6610 VT1 Price Schedule $67.00 DE3B Same as VT-1 except with fused leads 6610 VT1S 74.00 DE3B Deluxe Simulated Leather Carrying Case 6610 L2 39.30 DE3B Replacement Polarity Indication Cap b 6610 PC1 8.00 DE3B Replacement Leads b 6610 P1 25.70 DE3B Fused Replacement Leads b 6610 P1S 35.50 DE3B b IMPORTANT: Will fit only Class 6610 Series A testers and Catalog Number 5008, Series B testers. Will not fit 5008 Pre-Series B testers. Leads must be replaced as a unit. Replacement of individual lead components must not be attempted. Wiggy® Voltage Tester 14 © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz HOMELINE® Circuit Breakers Class 750, 751, 911 www.SquareD.com For the most up-to-date information Plug-On Circuit Breakers—UL Listed 10,000 Amperes RMS Symmetrical Interrupting Rating (AIR) The Square D HOMELINE circuit breakers are in a 1-inch wide industrystandard format for 1-pole circuit breakers. They are designed to plug into HOMELINE load centers that are available from 4 to 42 circuits. The Square D exclusive QWIK-OPEN® mechanism is standard on all 15 A and 20 A circuit breakers with a trip reaction within 1/60th of a second. HOM 1-pole—120/240 Vac Ampere Rating Catalog Number Price 10,000 Amperes RMS—UL Listed Interrupting Rating 15 HOM115 ab $17.50 20 HOM120 ab 17.50 25 HOM125 b 17.50 30 HOM130 b 17.50 35 ... ... 40 HOM140 b 17.50 45 ... ... 50 HOM150 b 17.50 60 ... ... 70 ... ... 80 ... ... 90 ... ... 100 ... ... 110 ... ... 125 ... ... 150 ... ... 175 ... ... 200 ... ... 2-pole—120/240 Vac Common Trip Catalog Number Price HOM215 b HOM220 b HOM225 b HOM230 b HOM235 b HOM240 b HOM245 b HOM250 b HOM260 b HOM270 b HOM280 b HOM290 b HOM2100 b HOM2110 b HOM2125 b HOM2150BB bc HOM2175BB bc HOM2200BB bc $ 40.30 40.30 40.30 40.30 40.30 40.30 40.30 40.30 40.30 82.00 112.00 112.00 112.00 246.00 246.00 285.00 285.00 285.00 Ampere Rating d 2-pole Tandem—120/240 Vac (Two Spaces Required) 1P 2P Catalog No. Price 10,000 AIR (2) 15 15 HOMT1515215 b $80.00 (2) 15 20 HOMT1515220 b 80.00 (2) 15 25 HOMT1515225 b 80.00 (2) 15 30 HOMT1515230 b 80.00 (2) 15 40 HOMT1515240 b 80.00 (2) 15 50 HOMT1515250 b 80.00 (2) 20 20 HOMT2020220 b 80.00 (2) 20 25 HOMT2020225 b 80.00 (2) 20 30 HOMT2020230 b 80.00 (2) 20 40 HOMT2020240 b 80.00 (2) 20 50 HOMT2020250 b 80.00 Typical catalog number (e.g. HOMT 1515230) represents two single-pole, outer poles (two 15 A 1P CBs) and one 2-pole inner circuit breaker with common trip (one 30 A 2P CB). HOM 1-pole HOM 2-pole HOMT 1-pole HOMT Quad Breaker 1 Space Required 2 Spaces Required 1 Space Required 2 Spaces Required HOM 1-pole AFI (Arc Fault Circuit Interrupter) HOM 1-pole GFI (With Ground Fault Circuit Interrupter) HOM 2-pole GFI (With Ground Fault Circuit Interrupter) HOM2200BB Branch Breaker 2 Spaces Required 4 Spaces Required HOM-HM High magnetic trip circuit breakers are recommended for applications where high initial inrush current may occur. 1-pole—120/240 Vac Catalog Number Price HOM115HMb $18.40 HOM120HMb 18.40 Amperes 15 20 2-poles ... ... ... HOM-AFI HOMELINE Arc Fault Circuit Interrupters—Provide overload and short circuit protection, plus arc fault protection in accordance with UL 1699. Ampere Rating Poles 120 Vac Catalog Number Price 15 20 1 1 HOM115AFIb HOM120AFIb $150.00 150.00 Circuit Breaker Wire Sizese Breaker Type Ampere Rating HOM 1-pole 15–30 40–50 15–30 35–70 80–125 150–200 15–30 40–50 15–20 15–50 HOM-GFI HOM-GFI circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more. Ampere Rating 1-pole—120 Vac 1 Space Required Catalog Number Price 10,000 AIR 15 20 30 40 50 HOM-EPD Amperes 10,000 AIR 15 20 25 30 40 50 2-pole—120/240 Vac Common Trip 2 Spaces Required Catalog Number Price 1 Space Required 1 Space Required HOM 2-pole HOMT and Quad Quad Only HOM-GFI - 1-pole HOM-GFI - 2-pole Wire Size (AWG/kcmil) Aluminum Copper #14–8 #14–8 or (2) #14–10 #8–2 #8–2 #14–8 #14–8 or (2) #14–10 #8–2 #8–2 #4–2/0 #4–2/0 #4–300 #4–300 #14–8 #14–8 #6–#12 #6–#14 #14–10 #14–10 #12–4 #14–6 Accessories HOM115GFI HOM120GFI ... ... ... $141.00 141.00 ... ... ... HOM215GFI HOM220GFI HOM230GFI HOM240GFI HOM250GFI $275.00 275.00 275.00 275.00 275.00 HOMELINE Equipment Protection Device—Circuit Breakers with 30 mA Equipment Ground Fault Protection (UL Listed) 2-pole—120/240 Vac 1-pole—120 Vac Common Trip Catalog Number Price Catalog Number Price HOM115EPD HOM120EPD ... ... ... ... $249.00 249.00 ... ... ... ... HOM215EPD HOM220EPD HOM225EPD HOM230EPD HOM240EPD HOM250EPD $440.00 440.00 440.00 440.00 440.00 440.00 HOMT Tandem Circuit Breakers Ampere Rating d 10,000 AIR 15 and 15 15 and 20 20 and 20 30 and 15 30 and 20 1-pole Tandem—120/240 Vac (One Space Required) Catalog No. Price HOMT1515 b HOMT1520 b HOMT2020 b HOMT3015 b HOMT3020 b $34.90 34.90 34.90 34.90 34.90 a UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads. b UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. c Requires four spaces (#1–300 kcmil Al/Cu). Use only in single phase panel rated 150 A or greater. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE3D jDE3C Description Catalog No. HANDLE ATTACHMENTS Handle Tie: Converts any two adjacent 120/240 Vac single HOM breakers to independent trip 2-pole Handle Tie: Converts any two adjacent 120/240 Vac single-pole side-by-side HOMT breakers to independent trip 2-pole Handle Clamp: Clamp for holding HOM single-pole handle in “ON’’ or “OFF’’ position Handle Blocking Device: Attaches to standard HOM 2-pole circuit breakers for holding the handle in the “OFF” position Handle Padlock Attachment: For padlocking 1-pole Standard HOM breakers in “ON’’ or “OFF’’ position. A Handle Padlock Attachment: For padlocking 2-pole 15–70 80–125 A Standard HOM breakers in “ON’’ or “OFF’’ position 150–200 A Handle Padlock Attachment: For padlocking center poles of Homeline Quad breakers in “OFF” position. Handle Padlock Attachment: For padlocking main circuit breakers in convertible load center, “OFF” SUB-FEED LUGS 125 A 2-pole plug-on—2 spaces required 225 A 2-pole plug-on—4 spaces required Price HOM1HT $ 2.30j HOMTHT 2.50j QO1LO 2.50v HOM2HBD 7.10j HOM1PA HOM2PALA HOM2PAHA HOM2PAVHA HOMQPA 50–125 A QOM1PAf 100–225 A QOM2PAf HOML2125 HOML2225c 6.60j 6.60j 6.60j 33.60j 6.60 7.20v 7.20v 31.70 197.00 d 15–20 A tandem or quad tandem circuit breakers are suitable for use with 60°C or 75°C conductors. 25–50 A tandem or quad tandem circuit breakers are suitable for use with 75°C conductors only. e 15–30 A circuit breakers are suitable for use with 60°C or 75°C conductors. 40–125 A circuit breakers are suitable for use with 75°C conductors. f 50–125 A QOM1 frame size; 100–225 A QOM2 frame size. vDE2E Discount Schedule 15 LOAD CENTERS HOMT Quad Tandem Circuit Breakers Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz HOMELINE® Load Centers Series Rating Class 1170 www.SquareD.com For the most up-to-date information The rating of the load center is equal to the lowest interrupting rating of any circuit breaker installed or combination series connected circuit breaker. Additional or replacement circuit breakers MUST have an interrupting and voltage rating equal to or greater than that of the circuit breaker with the lowest interrupting and voltage rating presently installed. See load center interior for circuit breaker types. Short Circuit Current Rating LOAD CENTERS Maxium Short Circuit Current Rating (RMS Symmetrical) 10,000 Load Center Voltage Rating 240 Vac Max. Systems Voltage 120/240 Vac, 1 Phase 3 Wire Remote Square D Circuit Breaker Catalog Designation b Current Rating Amperes Max. Integral Square D Circuit Breaker Catalog Designation b Current Rating Amperes Max. … … … … … … QOM-VH … 225 … Square D Branch Circuit Breaker Catalog Designation bc Current Rating Amperes 1-pole 2-pole HOM 15–50 15–200 a HOMT 15–30 15–50 HOM 15–50 15–200 a HOMT 15–30 15–50 HOM 15–50 15–200 a HOMT 15–30 15–50 HOM 15–50 15–200 a HOMT 15–30 15–50 HOM 15–50 15–200 a HOMT 15–30 15–50 HOM 15–50 15–200 a HOMT 15–30 15–50 HOM 15–50 15–200 a HOMT 15–30 15–50 Series Combination Short Circuit Current Rating 22,000 120/240 Vac, 1 Phase 3 Wire QO-VH 42,000 25,000 65,000 100,000 120/240 Vac, 1 Phase 3 Wire 120/240 Vac, 1 Phase 3 Wire 120/240 Vac, 1 Phase 3 Wire 120/240 Vac, 1 Phase 3 Wire QOH QD QG QJ 200 125 225 225 225 … … … … … … … … … … a 100 Amperes maximum branch circuit breaker in load centers with 125 A maximum mains rating. b See circuit breaker for voltage and interrupting rating. c HOM includes suffixes: GFI and AFI. 16 © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz HOMELINE® Load Centers Indoor—Single Phase, Main Lug, Main Circuit Breaker Class 1170 www.SquareD.com For the most up-to-date information Single Phase Three Wire—120/240 Vac—UL Listed—10,000 RMS Sym. Amperes Short Circuit Current Rating Mains Rating (A) Spaces Max. Number Single Pole Circuitsa Max. Number of Tandem Circuit Breakers Load Center Box, Interior and Cover b Catalog Number Main Wire Size AWG/kcmil Price (DE3C) Al Cu Equipment Ground Bar Kit (Order Separately) Catalog Number Price (DE3A) PK3GTA1 $ 7.60 Box No. See page 19 Main Lugs—Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from page 15 Factory-installed Fixed Main Lugs 2 4 2 HOM24L70F/S c d 6 12 6 HOM612L100F/S c e 52.00 125 4 8 4 HOM48L125GC 57.00 $ 39.20 #12–3 #14–4 #8–1 #12–2/0 PK7GTA #14–2/0 7.80 PK7GTA Factory-included 2 4 21 LOAD CENTERS 70 100 Convertible Mains—Factory-installed Main Lugs QOM1 Main Frame Size—Convertible to 22,000 AIR Main Circuit Breaker (See page 18) 125 8 8 12 12 16 20 20 24 16 16 12 24 24 20 24 24 8 8 0 12 8 0 4 0 HOM816L125C HOM816L125TC HOM12L125C HOM1224L125TC HOM1624L125C HOM20L125C HOM2024L125TC HOM24L125TC 88.00 100.00 116.00 136.00 173.00 158.00 192.00 229.00 #6–2/0 PK15GTA Factory-installed PK15GTA Factory-installed PK15GTA PK15GTA Factory-installed Factory-installed 11.40 ... 11.40 ... 11.40 11.40 ... ... 6 6 6 6 8 8 8 8 14.20 10 Convertible Mains—Factory-installed Main Lugs QOM2 Main Frame Size—Convertible to 22,000 AIR Main Circuit Breaker (See page 18) 150 30 30 0 HOM30L150C 250.00 #6–250 PK23GTA 200 16 16 20 32 32 40 16 16 20 HOM1632L200TC HOM1632L200TCFTf HOM2040L200TC 238.00 383.00 278.00 #6–250 Factory-installed ... 9 10 9 200 30 30 30 40 30 30 40 40 0 0 10 0 HOM30L200C HOM30L200TC HOM3040L200TC HOM40L200C 280.00 309.00 319.00 412.00 #6–250 PK23GTA Factory-installed Factory-installed PK23GTA 14.20 ... ... 14.20 10 10 10 12 225 42 42 0 HOM42L225C 488.00 #6–250 PK23GTA 14.20 12 I N Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating D Convertible Mains—Factory-installed Main Circuit Breaker O QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 18) O 8 16 8 HOM816M100C $210.00 #6–1 PK15GTA R 8 16 8 HOM816M100TC 222.00 #6–1 Factory-installed 100 125 12 12 20 24 30 12 24 20 24 30 0 12 0 0 0 HOM12M100C HOM1224M100TC HOM20M100C HOM24M100C HOM30M100C 196.00 256.00 264.00 342.00 448.00 #4–2/0 #4–2/0 #4–2/0 #4–2/0 #4–2/0 PK15GTA Factory-installed PK15GTA PK15GTA PK23GTA 11.40 ... 11.40 ... 11.40 11.40 14.20 5 5 6 6 8 8 10 12 12 24 30 24 24 24 30 12 12 0 0 HOM1224M125C HOM1224M125TC HOM24M125C HOM30M125C 404.00 413.00 473.00 541.00 #4–2/0 PK15GTA Factory-installed PK15GTA PK23GTA 11.40 ... 11.40 14.20 6 6 8 10 Factory-installed Factory-installed PK23GTA ... ... 14.20 9 9 10 Factory-installed Factory-installed PK23GTA Factory-installed ... ... 14.20 ... 9 9 9 9 PK23GTA Factory-installed PK23GTA PK23GTA 14.20 ... 14.20 14.20 10 10 12 12 PK23GTA 14.20 12 Factory-installed Factory-installed Factory-installed ... ... ... 9 9 10 Convertible Mains—Factory-installed Main Circuit Breaker QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 18) 150 200 225 16 20 30 32 30 30 16 10 0 HOM1632M150TC HOM2030M150TC HOM30M150C 424.00 500.00 517.00 12 16 20 20 24 32 40 40 12 16 20 20 HOM1224M200TC HOM1632M200TC HOM2040M200C HOM2040M200TC 381.00 450.00 474.00 509.00 30 30 40 42 30 40 40 42 0 10 0 0 HOM30M200C HOM3040M200TC HOM40M200C HOM42M200C 532.00 594.00 679.00 729.00 42 42 0 HOM42M225C 744.00 #4–250 #4–250 #4–250 Universal Mains—No Factory-installed Main Circuit Breaker or Main Lugs QOM2 Main Frame Size—Field-install 22,000 AIR Main Circuit Breaker or Main Lugs (See page 18) 200 16 20 30 32 40 40 16 20 10 HOM1632U200TC HOM2040U200TC HOM3040U200TC 195.00 238.00 353.00 #4–250 Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum number of single pole branch circuits utilizing HOM and/or HOMT circuit breakers. b C at end of catalog number indicates combination flush/surface cover included with device. c F/S at end of catalog number indicates to order F for flush device or S for surface device. The cover does not have a door. d HOM-GFI branch circuit breaker is limited to number 10 maximum wire. e 70 A maximum back feed main circuit breaker. f Supplied with feed-thru lugs. For additional information, reference Catalog #1100CT9901. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE3A DE3C Discount Schedule 17 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz HOMELINE® Load Centers Rainproof—Single Phase, Main Lug, Main Circuit Breaker Class 1170 www.SquareD.com For the most up-to-date information Single Phase Three Wire—120/240 Vac—UL Listed—10,000 RMS Sym. Amperes Short Circuit Current Rating Main Lugs—Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from page 15 Mains Rating (A) Spaces a Max. Number Single Pole Circuits Max. Number of Tandem Circuit Breakers Load Center Box, Interior and Cover Catalog Number Main Wire Size AWG/kcmil Price (DE3C) Al #12–3 Equipment Ground Bar Kit (Order Separately) Box No. See page 20 Cu Catalog Number Price (DE3A) #14–4 PK4GTA $ 7.20 1R PK7GTA 7.80 2R PK7GTA Factory-included 15R LOAD CENTERS Factory-installed Fixed Main Lugs 70 2 4 2 HOM24L70RB b $ 74.00 100 6 12 6 HOM612L100RB 86.00 #8–1 125 4 8 4 HOM48L125GRB 91.00 #12–2/0 #14–2/0 R A Convertible Mains—Factory-installed Main Lugs c I QOM1 Main Frame Size—Convertible to 22,000 AIR Main Circuit Breaker (See Below) N 8 16 8 HOM816L125RB 165.00 P 12 12 0 HOM12L125RB 156.00 125 #6–2/0 R 12 24 12 HOM1224L125RB 185.00 20 20 0 HOM20L125RB 255.00 O O F Convertible Mains—Factory-installed Main Lugs c QOM2 Main Frame Size—Convertible to 22,000 AIR Main Circuit Breaker (See Below) 12 20 30 40 200 12 40 30 40 0 20 0 0 HOM12L200RB HOM2040L200RB HOM30L200RB HOM40L200RB 282.00 373.00 391.00 607.00 #6–250 PK15GTA PK15GTA PK15GTA PK15GTA 11.40 11.40 11.40 11.40 3R 3R 3R 4R PK23GTA PK23GTA PK23GTA PK23GTA 14.20 14.20 14.20 14.20 5R 6R 7R 14R Main Circuit Breaker— 22,000 RMS Sym. Amperes Short Circuit Current Rating d Convertible Mains—Factory-installed Main Circuit Breaker c QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) 100 8 12 20 16 12 20 8 0 0 HOM816M100RB HOM12M100RB HOM20M100RB 286.00 277.00 354.00 #4–2/0 PK15GTA PK15GTA PK15GTA 11.40 11.40 11.40 3R 3R 4R 125 24 24 0 HOM24M125RB 572.00 #4–2/0 PK15GTA 11.40 6R Convertible Mains—Factory-installed Main Circuit Breaker c QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below) R 150 30 30 0 HOM30M150RB A 20 40 20 HOM2040M200RB I 30 30 0 HOM30M200RB 200 N 30 40 10 HOM3040M200RB 40 40 0 HOM40M200RB P R 16 24 8 HOM1624M225RB 225 42 42 0 HOM42M225RB O O Factory-installed Main Circuit Breaker with Feed-thru Lugsc F #4–250 PK23GTA 14.20 7R 581.00 669.00 768.00 851.00 685.00 #4–250 PK23GTA PK23GTA PK23GTA PK23GTA 14.20 14.20 14.20 14.20 6R 7R 7R 14R 788.00 882.00 #4–250 PK15GTA PK23GTA 11.40 14.20 7R 14R 150 8 16 8 HOM816M150FTRB 523.00 #4–250 PK15GTAL 23.30 6R 200 e 8 16 8 HOM816M200FTRB 523.00 #4–250 PK15GTAL 23.30 6R PK15GTAL 23.30 6R Universal Main with Feed-thru Lugs—No Factory-installed Main Circuit Breaker c QOM2 Main Frame Size—Field-install 22,000 AIR Main Circuit Breaker (See Kits Below) 200 8 16 8 HOM816U200FTRB Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2. a Maximum number of single pole branch circuits utilizing HOM and/or HOMT circuit breakers. b HOM-GFI branch circuit breaker is limited to number 10 maximum wire. c Side hinge door device allow 11⁄4" on left side for door to open. d 22,000 AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10,000 AIR branch circuit breakers to permit their application on systems with up to 22,000 A available fault current. e Rated 200 A when using copper wire. Reference NEC® Table 310.15(B)(6) when using Al wire. #4–250 Main Circuit Breaker Kits Field-installable Main Circuit Breaker (Convertible Load Centers Only) Main Circuit Breaker Rating (A) i Use With Convertible Load Center Mains Rating 22,000 AIR j Main Circuit Breaker Price (DE3A) Lug Wire Size k AWG/kcmil Al or Cu QOM1 Frame Size Main Lug Kits QOL125 QOL225 50 60 100–125 100–125 QOM50VH QOM60VH $ 93.00 93.00 70 80 90 100–125 100–125 100–125 QOM70VH QOM80VH QOM90VH 93.00 134.00 134.00 100 110 125 100–125 125 125 QOM100VH QOM110VH QOM125VH 134.00 312.00 312.00 QOM2100VH QOM2125VH QOM2150VH QOM2175VH QOM2200VH QOM2225VH 312.00 312.00 312.00 312.00 312.00 312.00 #12–2/0 QOM2 Frame Size l Field-installable Main Lugs (Convertible Load Centers Only) Main Lug f Ampere Rating Use On Convertible Load Center With Mains Rating Catalog Number Price (DE3A) Lug Wire Size g AWG/kcmil Al or Cu 125 225 100–125 150–225 QOL125h QOL225h $29.40 69.00 #6–2/0 #6–300 f Do not exceed the load center mains rating. g Wire Range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size permitted in a particular load center per UL, see pages 17, 18 under main wire size. h If main circuit breaker knockout has been removed from the load center’s trim, order appropriate filler plate from page 14. For additional information, reference Catalog #1100CT9901. 18 297.00 DE3A DE3C 100 125 150 175 200 225 150–225 150–225 150–225 200–225 200–225 225 #4–300 i Do not exceed the load center mains rating. j 22,000 AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10,000 AIR branch circuit breakers to permit their application on systems with up to 22,000 amperes available fault current. k Wire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find out maximum wire size permitted in a particular load center per UL, see pages 17,18 under Main Wire Size. l Add suffix 1021 for 120, 208, 240 Vac shunt trip. Add $126.00. Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® and HOMELINE® Load Centers Indoor—Dimensions, Knockouts Class 1130, 1170 www.SquareD.com For the most up-to-date information Knockout Information and Enclosure Dimensions Indoor Dimensions H D Box No. IN 1 3.81 97 6.72 171 3.00 76 2 4.81 122 9.30 236 3.19 81 3 4.81 122 9.30 236 3.19 4 8.88 226 12.57 319 3.80 5 14.25 362 14.92 379 3.75 mm IN mm IN W Box No. A H IN mm IN mm IN mm 13 5.88 149 13.12 333 3.38 86 14 14.25 362 20.92 531 3.75 95 81 15 20.00 508 50.00 1270 5.75 146 97 16 20.00 508 68.00 1727 5.75 146 95 17 20.00 508 53.00 1346 5.75 146 5.88 149 16.12 409 3.38 86 7.56 192 23.12 587 4.25 108 mm 6 14.25 362 17.92 455 3.75 95 18 7 14.25 362 20.92 531 3.75 95 19 95 20 9.62 244 26.12 663 4.75 8 14.25 362 26.04 661 3.75 9 14.25 362 29.86 758 3.75 95 21 8.88 226 14.80 376 3.80 97 14.25 362 33.78 858 3.75 95 22 8.55 217 23.92 608 3.95 100 11 14.25 362 37.98 965 3.75 95 23 14.25 362 29.86 758 3.75 95 12 14.25 362 39.37 1000 3.75 95 B,C,D,E B,C,D,E C,D,E,F,G A A,B C,D,E,F,G A B 1⁄2 3⁄4 C D E 1 11⁄4 11⁄2 A A Box 1 B,C,D,E A A,B C,D,E,F,G G 2 21⁄2 A B,C,D,E A A,B B,C,D,E A A B,C,D,E A,B,C,D B,C,D,E I 3 31⁄2 Box 5 Box 4 C,D,E,F,G D,E,F,G B,C,D,E C,D,E,F A A,B B,C,D,E D,E,F,G C,D,E,F,G D,E,F,G A A,B B,C,D,E D,E,F,G B,C B,C,D,E C,D,E,F B,C A,B B,C,D,E C,D,E,F C,D,E,F,G C,D,E,F A,B H A A,B B,C,D,E B,C,D,E B,C,D,E B,C,D,E C,D,E,F C,D,E,F Box 3 Box 2 A,B A A,B B,C,D,E F A,B,C A A,B,C Knockouts Symbol A,B,C A 121 10 Conduit Size A,B,C,D A,B,C D LOAD CENTERS Dimensions W A,B A,B A A,B A A A A,B,C,D A,B,C,D Box 6 B,C,D,E C,D,E,F C,D,E,F,G D,E,F,G B,C,D,E Box 7 A A,B B,C,D,E D,E,F,G B,C,D,E B,C,D,E A,B,C,D Box 8 C,D,E,F,G D,E,F,G A,B,C,D C,D,E,F D,E,F,G A,B,C,D C,D,E,F D,E,F,G Box 10 Box 9 A A,B C,D,E,F D,E,F,G A,B,C A C,D,E,F A,B D,E,F,G A,B B,C,D,E C,D,E,F A,B,C,D D,E,F,G,H D,E,F,G,H,I C,D,E,F B,C B,C A,B A,B A,B A A A A,B,C,D B,C,D,E Box 13 Box 14 A,B,C,D C,D,E,F D,E,F,G A,B,C,D B,C,D,E C,D,E,F Box 15, 16, 17 Box 12 Box 11 A,B,C C,D,E,F E,F,G,H C,D,E,F A D,E,F,G A,B,C,D A,B D,E,F,G A C,D,E,F B,C,D,E D,E,F,G D,E,F,G A,B B,C,D,E D,E,F,G B,C,D,E B,C,D,E B,C B,C,D,E B,C,D,E B,C,D,E Box 18 Box 19 Box 20 A,B A,B A C,D,E,F A Box 22 Box 21 A,B,C,D C,D,E,F D,E,F,G Box 23 © 2004 Schneider Electric All Rights Reserved 6/7/04 19 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® and HOMELINE® Load Centers Rainproof—Dimensions, Knockouts, Bolt-On Hubs Class 1130, 1170 www.SquareD.com For the most up-to-date information Enclosure Dimensions 2 1⁄2" Hub Maximum 2 1⁄2" Hub Maximum Dimensions W Box No. A,B,C A A,B A,B,C,D Box 1NM B,C,D,E A Box 1R B,C,D,E B,C,D,E A,B Box 2R 2 ⁄2" Hub Maximum 1 LOAD CENTERS 2 1⁄2" Hub Maximum C,D,E,F,G C,D,E,F,G C,D,E,F A,B,C A A,B C,D,E,F,G C,D,E,F C,D,E,F Box 3R, 4R A,B,C A A,B C,D,E,F,G C,D,E,F Box 5R 2 1⁄2" Hub Maximum H D IN mm IN mm IN 1NM 6.52 166 8.79 223 3.90 mm 99 1Ra 4.88 124 9.38 238 4.00 102 2R 8.88 226 12.65 321 4.27 108 3R 14.75 375 18.92 481 4.52 115 4R 14.75 375 22.06 560 4.52 115 5R 14.75 375 26.04 661 4.52 115 6R 14.75 375 29.86 758 4.52 115 7R 14.75 375 33.78 858 4.52 115 8R 14.75 375 37.98 965 4.52 115 9R 4.56 116 6.50 165 3.88 99 10R 6.92 176 13.18 335 4.12 105 11R 7.56 192 23.24 590 4.75 121 12R 9.62 244 26.24 666 5.50 140 13R 6.92 176 16.18 411 4.12 105 14R 14.75 375 39.37 1000 4.52 115 15R 8.88 226 14.80 376 4.27 108 16R 8.55 217 24.75 629 4.16 106 a HOME250SPA top endwall has no hub opening. Knockout Information Knockouts C,D,E,F,G A,B,C Symbol A B Conduit Size 1⁄2 3⁄4 C D E 1 11⁄4 11⁄2 F G H 2 21⁄2 3 Box 9R C,D,E,F A,B,C A A,B C,D,E,F,G 2 1⁄2" Hub Maximum C,D,E,F Box 6R, 7R, 8R 2 1⁄2" Hub Maximum 2 1⁄2" Hub Maximum 2 1⁄2" Hub Maximum 2 ⁄2" Hub Maximum 2 ⁄2" Hub Maximum 1 1 A,B C,D,E,F,G C,D,E,F B,C,D,E A,B,C,D B,C,D,E C,D,E,F A,B Box 16R Box 15R E,F E,F,G,H Box 11R B,C,D,E A B,C,D,E D,E,F,G D,E,F,G Box 10R, 13R B,C,D,E Box 12R C,D,E,F Bolt-On Hubs A,B,C A A,B C,D,E,F,G C,D,E,F Box 14R Square D equipment with “R’’ or “RB’’ suffix, designated rainproof NEMA 3R rainproof construction, utilizes bolt-on hubs listed below. “RB’’ devices will accept 3⁄4" through 2" bolt-on hubs without the use of reducers. Off-center conduit thread openings and elongated mounting holes provide quick and easy adjustment to eliminate costly conduit offsets and bends. Catalog suffix “R’’ devices require 3" through 4" field cut opening. Hubs are suitable for use with conduit having ANSI standard taper pipe thread. Bolt-On Hubs UL Listed For “RB’’ Devices 3⁄4" Conduit Size 11⁄4" 1" 11⁄2" 2" 21⁄2" Hub Cat. No. B075 B100 B125 B150 B200 B250 Price $22.20 $22.20 $22.20 $22.20 $40.90 $68.00 Note: Closing cap (catalog number BCAP) is provided factory-installed on each device having “RB’’ suffix. Price if ordered separately; $2.50 Bolt-On Hubs UL Listed For Mounting In Field Cut Opening Conduit Size 3" 31⁄2" 4" Hub Cat. No. B300 B350 B400 Price $124.00 $200.00 $245.00 “RB’’ Hub 20 DE1A Discount Schedule Designed for mounting in field cut opening. Includes gasket and four mounting bolts and nuts. © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® Load Centers Wiring Diagrams—Single Phase Class 1130 www.SquareD.com For the most up-to-date information 1 Phase 3 Wire Main Lugs S N S/N S N G/B QO2L30S QO2L40RB S N S N QO11224L125G QO11224L125GC QO11224L125GRB QO11224L125GWGC S N S N S N QO116L125G S N G B QO24L60NRNMq QO24L70F/S QO24L70RB QO24L70TSq QO2L30TTSq S N S N S N S N S N QO11624L125G QO11624L125GRB S N S N S N S/N S N QO24L50TTSq S N S N QO612L100DFCU/SCU QO612L100DF/S QO612L100DTF/Sq QO612L100F/S QO612L100RB QO612L100RBCU QO612L100TF/Sq QO612L100TRBq QO816L100DF/S QO816L100DFCU/SCU QO816L100DTF/Sq QO816L100F/S QO816L100RB QO816L100RBCU QO816L100TF/Sq S N QO112L125G QO112L125GC QO112L125GRB QO112L200G QO112L200GRB S N S N S N QO120L125G QO120L125GC S N S N S N S N QO12024L125G QO12024L125GWGC S N QO12030L150G S N S N S N G B QO124L125G QO124L125GRB QO124L150G QO12436L200TFT QO130L150G QO130L150GRB QO130L200G QO130L200GRB QO132L125G S/N S/N S/N QO13040L200G QO13040L200GC QO13040L200GRB QO13040L200WG QO140L200G QO140L200GRB S/N S/N QON12LS400 QO142L225G QO142L225GRB Main Main QO148L125GF/S QO148L125GRB QON30LS400 QO48M30DSGP QO48M60DSGP Generator Panel QON42LS400 1 Phase 3 Wire Main Breaker S N Line Main S N Main S N S N Main S N S N Main S N S N Main S N S N Main S N S F S/N G/B QO35FM30TTFq QO35FM30TTSq QO1612M125FTRB QO1816M150FTRB QO1816M200FTRB QO112M100 QO112M100C QO112M100RB QO116M100 QO116M100C QO116M100RB QO11220M100C QO120M100 QO120M100C QO120M100RB q Includes Factory Installed Ground Bar © 2004 Schneider Electric All Rights Reserved 6/7/04 21 LOAD CENTERS S N Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz QO® Load Centers Wiring Diagrams—Single & Three Phase Class 1130 www.SquareD.com For the most up-to-date information 1 Phase 3 Wire Main Breaker (Continued) S/N LOAD CENTERS S N Main QO12030M150 QO12030M150C QO12030M150RB S N Main S N S N S N Main S N QO124M100 QO124M125 QO124M125RB QO124M150 QO124M200 S N Main S N S N QO130M150 QO130M150C QO130M150RB QO130M200 QO130M200C QO130M200RB Main S N QO132M100 QO132M125 QO132M150 S N Main S N S N Main S N S N Main S N QO13040M200 QO13040M200C QO140M200 QO140M200C QO140M200RB QO140M225 Main QON42MS300 QON42MS400 QO142M200 QO142M225 QO12040M200 QO12040M200C QO12040M200RB QO12040M200TCq 3 Phase 4 Wire Main Lugs S N S N S N S N S N S N S N S N S N S N S N S N S N QO403L60NF/S QO403L60NRB QO312L125G QO312L125GRB QO320L125G QO320L125GRB QO318L200G QO318L200GRB QO324L125G QO330L200G QO330L200GRB QO342L225G QO342L225GRB 3 Phase 4 Wire Main Circuit Breaker S N S N S N Main S N S N Main S N M a i n QO327M100 QO327M100RB QO330MQ125 QO330MQ125RB QO330MQ150 QO330MQ150RB QO330MQ200 QO330MQ200RB QO342MQ150 QO342MQ200 QO342MQ200RB QO342MQ225 QO342MQ225RB q Includes Factory Installed Ground Bar 22 © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz HOMELINE® Load Centers Wiring Diagrams Class 1170 www.SquareD.com For the most up-to-date information 1 Phase 3 Wire Main Lugs S N S/N S/N HOM48L125GC HOM48L125RB HOM612L100F/S HOM612L100RB S N S N S N S N S N S N S N S N S N S N S N G B G B HOM12L125C HOM12L125RB HOM12L200RB S N S N S N S N S N G B HOM2024L125TCq S N S N G B HOM2040L200TCq HOM24L125TCq S N S N S N G B HOM30L150C HOM30L200C HOM30L200RB HOM30L200TCq HOM3040L200TCq HOM40L200C HOM40L200RB HOM42L225C 1 Phase 3 Wire Main Breaker Main S N S N S N G B HOM20L125C HOM20L125RB HOM1632L200TCFTq S N HOM1624L125C HOM1224L125TCq HOM1224L125RB G B HOM1632L200TCq S N S N S N S N G B HOM816L125C HOM816L125RB HOM816L125TCq S N S N S N Main S N S N Main S N S N Main Main S N S N Main S N S N G B HOM816M100C HOM816M100RB HOM816M100TCq S N Main HOM816M150FTRB HOM816M200FTRB S N S N Main S N Main S N G B Main S N S N Main S N S N Main HOM1624M225RB S N S N Main S N G B HOM1632M150TCq HOM1632M200TCq S N HOM1224M125C HOM12M100C HOM12M100RB S N HOM1224M100TCq HOM1224M125TCq HOM1224M200TCq HOM20M100C HOM20M100RB S N Main HOM2030M150TCq S N S N Main S N HOM2040M200C HOM2040M200RB HOM2040M200TCq HOM24M100C HOM24M125C HOM24M125RB HOM30M100C HOM30M125C HOM30M150C HOM30M150RB HOM30M200C HOM30M200RB Universal Mains S N S N S N S N HOM816U200FTRB S N S N S N S N HOM3040M200RB HOM3040M200TCq HOM40M200C HOM40M200RB q Includes Factory Installed Ground Bar © 2004 Schneider Electric All Rights Reserved 6/7/04 HOM42M200C HOM42M225C G B HOM1632U200TCq G B G B HOM2040U200TCq HOM3040U200TCq 23 LOAD CENTERS HOM24L70F/S HOM24L70RB Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Combination S E R V I C E E N T R A N C E D E V I C E ( C S E D ) Flexibility... Meter-Main CSEDs Meter main devices are used in residential applications where local codes require service disconnects to be located outside the dwelling. They include the utility meter socket and factory installed and/or provisions for field installation of service disconnect(s) to feed downstream devices. Meter mains are surface mount and typically used with interior mounted sub-feed load centers. All-In-One CSEDs These devices come with a 30/40 circuit 200 A main circuit breaker load center and an additional 200 A maximum service disconnect for subfeed applications. 300 A and 400 A versions are available. Meter Mains Square D meter mains include a basic meter socket and single main service disconnect. Dual main devices are available to feed a second load, such as a water pump, with a separate service disconnect. Four or six main disconnect units provide flexibility for feeding additional loads, such as air conditioning, spa, swimming pool, or garage. ■ Ring or ringless styles meet local utility requirements ■ Fifth jaw and horn bypasses available 24 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Combination Service Entrance Devices Rainproof—Single Phase, Meter-Mains Class 4119/4120 www.SquareD.com For the most up-to-date information Meter-Mains 200 None OH/UG RING TYPE QO® OH/UG HOMELINE QO OH/UG OH/UG 245. 681. 22k C2M200S 722. 10k C4L200S 762. 1 1 1 1 2 QOM1-VH QOM2-VH QOM2-VH QO-VH QO 125 200 200 50 100 ..... ..... .... .... ..... QDL22200a QDL, QGL, QJLn QOHe 200 ..... ..... 200 ..... ..... 200m ..... ..... ..... ..... ..... ..... ..... ..... A-L (2) Studs #4–250 98, 4 QDL22200a QDL, QGL, QJLn QOHe 200 ..... ..... 200 ..... ..... 200m ..... ..... ..... ..... ..... ..... ..... ..... A-L (2) Studs #4–250 98, 4 16 ..... 16 ..... 8 ..... 8 ..... 200 ..... 200 ..... A-L (2) Studs #4–250 98, 4 A-L (2) Studs #4–250 98, 4 125d ..... ..... 200 ..... ..... ..... ..... ..... ..... A A–L #6–2/0 #4–250 #12–4 #12–2/0 31, 24 40, 10 A or B300 #6–2/0 A–L #4–250 A–L #4–250 #12–2/0 #12–2/0 #12–2/0 37, 20 47, 10 51, 10 200 200 200 200 8 ..... 8 ..... 4 6 HOM HOM 10k SC8L125F 10k SC12L200F 22k SC816F200F g 564. 946. 791. 4 6 1 HOM HOM QOM2200VHa 110 200 200 ..... ..... ..... ..... 8 16 ..... ..... 8 ..... ..... 200 Surface Mount—Supplied with Feed Thru Lugs and provisions for Branch Circuit Breakers 22k SC816F150S g 791. 1 QOM2150VHa 150 None OH/UG OH/UG 1 HOM2150a 833. 10k SC816D150Cg h 1 HOM 22k SC816F200S g 791. 1 QOM2200VHa 200 None OH/UG OH/UG 1 HOM2200a 833. 10k SC816D200Cgh 1 HOM 150 150 50 200 200 50 8 8 ..... 8 8 ..... 8 8 ..... 8 8 ..... 150 100 ..... 200 100 ..... ..... 681. 722. 757. 1041. 1255. ..... 25k QU12L400SL l 2540. 1 1 1 6 6 1 1 4 Weight Each (Lbs) and Pallet Qty. ..... ..... ..... ..... ..... 564. 946. RC200S RC2M200S 22k RC2M200SH QC12L200Ci QC12L200CHi jk Service Ground Lug AWG/ kcmil (Al/Cu) ..... ..... ..... ..... ..... QDL22200a QDL, QGL, QJLn QDL22200a QDL, QGL, QJLn ..... ..... ..... ..... ..... 10k SC8L125S 10k SC12L200S Semiflush Mount only 125 None OH/UG OH/UG None OHf/UG OHf/UG 200 None OHf/UG OHf/UG Surface Mount Only None None 200 Horn OH/UG None Horn Class 400 320 UG Lever RINGLESS 10k C125RB 22k CM200S Surface Mount, convertible to Semiflush with FK400 flange kit (order separately) 1 400 None UG UG 25k CU12L400CN b 2540. 1 4 Class 1 400 320 UG UG 25k CU12L400CB b 2657. 1 Manual 4 Bypass 1 400 None UG UG 25k CU816D400CNgb 2650. 1 1 Class 1 320 UG UG 25k CU816D400CBgb 2767. 400 Manual Bypass Surface Mount only 125 None OH/UG 200 None OH/UG HOMELINE ... ... ... ... ... Type (Order Am2-pole from pere Circuits Separately page 27 Rating (Max.) except as noted) (Max.) Line Side Main Lugs AWG/ kcmil (Al/Cu) QOM2-VH QOM2-VH QO-VH QO-VH QO-VH QDL22200a QDL, QGL, QJLn QOHe 200 200 50 200 200 200 200 200m Surface Mount Only, Supplied with Feed Thru Lugs and provisions for Branch Circuit Breakers 100 Horn OH/UG ..... 22k QC816F100CHgijk 904. 1 QOM2100VHa OH/UG ..... 22k QC816F125Cgi 869. 1 QOM2125VHa 125 None Horn OH/UG ..... 22k QC816F125CHgij 904. 1 QOM2125VHa None OH/UG ..... 22k QC816F150Cgi 869. 1 QOM2150VHa 150 Horn OH/UG ..... 22k QC816F150CHgij 904. 1 QOM2150VHa OH/UG ..... 22k QC816F200Cgi 904. 1 QOM2200VHa 200 None Horn OH/UG ..... 22k QC816F200CHgij 904. 1 QOM2200VHa Class 1 QDL22200a 400 320 UG ..... 25k QU816D400SLg 2710. 1 QDL, QGL, QJLn Lever 16 16 ..... 16 16 ..... B A #4–1/0 #4–250 #8–1/0 (2) #8–2/0 15, 54 26, 24 A #4–250 (2) #8–2/0 27, 20 A #4–250 (2) #8–2/0 27, 28 A–L #4–250 #12–2/0 40, 10 A or A–L #6–300 #12–1/0 48, 18 A–L #4–250 #12–2/0 40, 10 A or A–L #6–300 #12–1/0 48, 18 #6–350 #6–350 #6–350 #6–350 #6–350 (2)#8–2/0 (2)#8–2/0 (2)#8–2/0 #12–2/0 #12–2/0 26, 24 27, 20 27, 20 40, 21 40, 21 ..... ..... ..... ..... A A A A A ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... ..... A-L 100 125 125 150 150 200 200 200 200 8 8 8 8 8 8 8 8 8 16 16 16 16 16 16 16 16 16 8 8 8 8 8 8 8 8 8 100 100 100 150 150 200 200 200 200 ..... ..... ..... 8 ..... (2) Studs #4–250 98, 4 #6–350 #12–2/0 40, 21 A-L (2) Studs #4–250 98, 4 A Surface Mount, convertible to Semiflush with FK400 flange kit (order separately) 1 400 Class UG UG 25k QU12L400CL lc 2540. 1 4 320 Lever 1 400 UG UG 25k QU816D400CL lcg 2710. 1 QDL22200a QDL, QGL, QJLn QOHe QDL22200a QDL, QGL, QJLn 200 200 200m 200 200 ..... ..... ..... 16 ..... ..... ..... ..... 8 ..... ..... ..... ..... 200 ..... A-L (2) Studs #4–250 98, 4 A-L (2) Studs #4–250 98, 4 Surface Mount Only 125 None OH/UG 200 None OH/UG 200 Horn OH/UG HOM HOM HOM 125d ..... ..... 200 ..... ..... 200 ..... ..... ..... ..... ..... ..... ..... ..... A A A #6–2/0 #6–350 #6–350 #12–4 #12–2/0 #12–2/0 27, 32 40, 21 40, 21 8 8 8 8 8 8 8 ... 100 100 150 150 200 200 100 ... A #6–350 #12–2/0 40, 21 A or B300 #6–300 #6–1/0 48, 18 ..... ..... ..... 10k RC8L125S 10k RC12L200Ci 10k RC12L200CHijk 564. 946. 946. 4 6 6 Surface Mount Only, Supplied with Feed Thru Lugs and provisions for Branch Circuit Breakers 100 Horn OH/UG ..... 22k RC816F100CHgij 818. 1 QOM2100VHa 125 Horn OH/UG ..... 22k RC816F125CHgij 818. 1 QOM2125VHa None OH/UG ..... 22k RC816F150Cgi 791. 1 QOM2150VHa 150 Horn OH/UG ..... 22k RC816F150CHgij 818. 1 QOM2150VHa OH/UG ..... 22k RC816F200Cgi 818. 1 QOM2200VHa 200 None Horn OH/UG ..... 22k RC816F200CHgij 818. 1 QOM2200VHa 1 HOM2200 a 200 Horn OH/UG ..... 10k RC816D200CHcghj 861. 1 HOM a Service disconnect supplied factory-installed. b For use only on 120/240 Vac, 1-Phase, 3-Wire system. (4-jaw meter socket.) c Knockout provided in cover for use with barrel lock kit, order catalog number SCBRLLOCK (see Accessories page 27). d 125 A HOMELINE® 2-pole circuit breaker can be installed in top position only. All other positions are limited to 100 A max. e UL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker installed. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE3A f g h i j k l m n 100 125 150 150 200 200 200 50 8 8 8 8 8 8 8 ... 16 16 16 16 16 16 16 ... Suitable for OH service with addition of tunnel kit (SCTK20). Order separately. Supplied with load side feed thru lugs, for #6 AWG–250 kcmil (Al/Cu) conductors. Convertible to semiflush with SC200F flange kit (order separately). Device supplied with barrel lock provisions factory-installed. Supplied with horn bypass and 5th jaw factory-installed. Not stocked in PDS, contact Lexington for delivery. 5th jaw factory-installed. QO panel is rated 200 A maximum. Circuit breaker prefix QBL at 10 kAIR may be used. For complete circuit breaker catalog number, see page 29. Discount Schedule 25 LOAD CENTERS Surface Mount only 125 None OH/UG OH/UG UL & EUSERC Catalog Number Ampere Rating (Max.) UL Service Disconnect(s) List Price (DE3A) Spaces Service (Type of Feed) Load Center and Branch Circuit Breakers (Order separately Hub page 27) Type Max. Quantity (Order separately 1-pole from page 27) Tandems Circuits Bypass Type Short Circuit Current Rating Ampere Rating Meets Federal Spec. W-P-115c as Type 1, Class 2, UL Listed, suitable only for use as service equipment, 120/240 Vac, 1-Phase, 3-Wire, NEMA 3R enclosure Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Combination Service Entrance Devices Rainproof—Single Phase, All-In-Ones Class 4120 www.SquareD.com For the most up-to-date information All-In-Ones Catalog Number Max. Quantity 2-pole Circuits (Max.) Type (Factory Installed) Ampere Rating (Max.) 1-pole Tandems Hub Type (Order Separately page 27) Service Disconnect(s) List Price (DE3A) Ampere Rating (Max.) Load Center & Branch Circuit Breakers (Order separately page 27) Circuits Service (Type of Feed) UL & EUSERC • Semiflush-REVERSE design available, supplied with load center (indoor access) • Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires. • Meets Federal Specification W-P-115c as Type 1, Class 2 Spaces LOAD CENTERS Bypass Type Short Circuit Current Rating Ring or ringless type meter socket designs available UL Listed, suitable only for use as service equipment Meets EUSERC standards Service disconnect(s) are supplied factory-installed, except where noted Ampere Rating • • • • Line Side Main Lugs AWG/ kcmil (Al/Cu) Service Ground Lug AWG/ kcmil (Al/Cu) Weight Each (Lbs) and Pallet Qty. A #6–2/0 #12–4 32, 24 Surface Mount only 100 None OH/UG 10k SC1624M100S $ 496. 1 HOM2100 100 16 24 8 100 125 None OH/UG 10k SC1624M125S 1012. 1 HOM2125 125 16 24 8 125a 200 None OH/UG 22k SC2040M200S 1114. 1 QOM2200VH 200 20 40 20 200 A-L #4–250 #12–2/0 45, 10 200 None OH/UG 10k SC2040M200C b 1199. 1 HOM2200 200 20 40 20 100 A or A-L #6–300 #12–1/0 47, 18 A or B300 #6–2/0 #12–2/0 44, 20 A-L #4–250 #12–2/0 Semiflush Mount only 100 RING TYPE HOMELINE 125 None None 200 None 225 None OH/UG 10k SC1624M100F $ 496. 1 HOM2100 100 16 24 8 100 OH/UG 10k SC1624M125F 1012. 1 HOM2125 125 16 24 8 110 OHc/UG 22k OHc/UG OHd/UG 22k SC2040M125F 1114. 1 QOM2125VH 125 20 40 20 110 SC2040M200F 1114. 1 QOM2200VH 200 20 40 20 200 SC3040M200F 1376. 1 QOM2200VH 200 30 40 10 200 22k SC3040M225F 1520. 1 QOM2225VH 225 30 40 10 200 51, 10 56, 10 Surface Mount only 100 None OHh 10k SO1020M100S $ 295. 1 HOM2100 100 10 20 10 80 A #6–1 #14–4 200 None OHh 22k SO2040M200S 774. 1 QOM2200VH 200 20 40 20 200 A #6–350 #8–2/0 43, 21 200 None OH/UG 22k SC3040M200S 1340. 1 QOM2200VH 200 30 40 10 200 #4–250 #12–2/0 50, 10 SC40M200S 1621. 1 QOM2200VH 200 40 40 0 200 #4–250 #12–2/0 52, 10 A-L 20, 42 REVERSE All-In-One - Semiflush Mount with Service Disconnect (outdoor access) and Load Center (indoor access) 200 None UG 10k SU3040M200R $1482. 1 QOM2200VH 200 225 None UG 10k SU3040M225R 1764. 1 QOM2225VH 225 30 40 10 200 A or B300 #6–300 #12–1/0 60, 15 A-L (2) Studs #4–250 100, 4 A-L (2) Studs #4–250 100, 4 A-L (2) Studs #4–250 100, 4 A #6–2/0 #12–4 32, 24 A #6–350 #12–2/0 40, 21 A-L (2) Studs #4–250 100, 6 A #6–350 #12–1/0 40, 21 Surface Mount, convertible to Semiflush with FK400 flange kit (order separately) 300 Class 320 Manual Bypass UG 25k SU3040D300CBfg 4400. 400 None UG 25k SU3040D400CNfg 4700. 400 Class 320 Manual Bypass UG 25k SU3040D400CBfg 4778. 1 QDL22200 200 30 40 10 200 1 QDL, QGL, QJLle 100 ..... ..... ..... ..... 1 QDL22200 200 30 40 10 200 1 QDL, QGL, QJLle 200 ..... ..... ..... ..... 1 QDL22200 200 30 40 10 200 1 QDL, QGL, QJLle 200 ..... ..... ..... ..... HOM2100 100 HOM2125 125 16 24 8 Surface Mount Only 100 125 HOMELINE RINGLESS 125 150 200 None OH/UGh 10k Horn OH/UGh 22k RC1624M100S 496. RC1624M125S 1012. RC2040M125CHij 1067. 1 QOM2125VH 125 20 40 20 100 1 100 125a Horn OH/UGh 22k RC2040M150CHij 1142. 1 QOM2150VH 150 20 40 20 150 None OH/UGh 22k RC2040M200Ci 1142. 1 QOM2200VH 200 20 40 20 200 Horn OH/UGh 22k RC2040M200CHij 1142. 1 QOM2200VH 200 20 40 20 200 200 All-In-One Surface Mount, convertible to Semiflush with FK400 flange kit (order separately) 400 Class 320 Lever 400 K-4 Bolt-On None UG UG 25k RU3040D400CLfk 4662. 25k RU3040D400CKf 4662. 1 QDL22200 200 30 40 10 1 QDL, QGL, QJLle 200 ..... ..... ..... ..... 1 QDL22200 200 30 40 10 200 1 QDL, QGL, QJLle 200 ..... ..... ..... QO Surface Mount Only 150 200 Horn OH/UGh 22k QC2442M150CHij 1270. 1 QOM2150VH 150 24 42 18 150 None OH/UGh 22k QC2442M200Ci 1270. 1 QOM2200VH 200 24 42 18 200 Horn OH/UGh 22k QC2442M200CHij 1270. 1 QOM2200VH 200 24 42 18 200 a 125 A HOMELINE® 2-pole circuit breaker can be installed in top position only. All other positions are limited to 100 A max. Convertible to semiflush with SC200F flange kit (order separately). Suitable for OH service with addition of tunnel kit (SCTK20). Order separately. Suitable for OH service with addition of tunnel kit (SCTK30). Order separately. UL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker installed. f Knockout provided in cover for use with barrel lock kit, order catalog number SCBRLLOCK (see Accessories page 27). b c d e 26 DE3A g h i j k l For use only on 120/240 Vac, 1-Phase, 3-Wire system (4-jaw meter socket). Device not EUSERC approved. Device supplied with barrel lock provisions factory-installed. Supplied with horn bypass and 5th jaw factory-installed. 5th jaw factory-installed. Additional service disconnect for field-installation, order prefix QBL at 10 kA, QDL at 25 kA, QGL at 65 kA or QJL at 100 kA. Order separately. For complete circuit breaker catalog number, see page 29. Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Combination Service Entrance Devices Circuit Breakers, Accessories, Hubs Class 4119/4120 www.SquareD.com For the most up-to-date information Type: HOM, 1-pole Type: HOM, 2-pole Type: QO, 1-pole Type: QO, 2-pole Type: QO-VH, 1-pole Type: QO-VH, 2-pole Ampere Rating Catalog Price Catalog Price Catalog Price Catalog Price Catalog Price Catalog Price a Number (DE3D) Number (DE3D) Number (DE2A) Number (DE2A) Number (DE2A) Number (DE2A) 10 ... ... ... ... QO110 $20.40 ... ... ... ... ... ... 15 HOM115 $17.50 ... ... QO115 19.40 ... ... QO115VH $42.30 ... ... 20 HOM120 17.50 ... ... QO120 19.40 ... ... QO120VH 42.30 ... ... 25 HOM125 17.50 ... ... QO125 19.40 ... ... QO125VH 48.50 ... ... 30 HOM130 17.50 HOM230 $ 40.30 QO130 19.40 QO230 $ 44.70 QO130VH 48.50 QO230VH $ 97.00 35 ... ... HOM235 40.30 QO135 20.40 QO235 46.90 ... ... ... ... 40 HOM140 17.50 HOM240 40.30 QO140 19.40 QO240 44.70 ... ... QO240VH 97.00 45 ... ... HOM245 40.30 QO145 20.40 QO245 46.90 ... ... ... ... 50 HOM150 17.50 HOM250 40.30 QO150 19.40 QO250 44.70 ... ... QO250VH 97.00 60 ... ... HOM260 40.30 QO160 20.40 QO260 44.70 ... ... QO260VH 97.00 70 ... ... HOM270 82.00 QO170 46.90 QO270 89.00 ... ... QO270VH 149.00 80 ... ... HOM280 112.00 ... ... QO280 126.00 ... ... QO280VH 210.00 90 ... ... HOM290 112.00 ... ... QO290 126.00 ... ... QO290VH 210.00 100 ... ... HOM2100 112.00 ... ... QO2100 126.00 ... ... QO2100VH 210.00 110 ... ... HOM2110 258.00 ... ... QO2110 285.00 ... ... QO2110VH 689.00 125 ... ... HOM2125 246.00 ... ... QO2125 285.00 ... ... QO2125VH 689.00 150 ... ... HOM2150BB 285.00 ... ... QO2150 327.00 ... ... QO2150VH 707.00 175 ... ... HOM2175BB 285.00 ... ... QO2175 327.00 ... ... QO2175VH 707.00 200 ... ... HOM2200BB 285.00 ... ... QO2200 327.00 ... ... QO2200VH 707.00 Ampere Type: QOM1-VH, 2-pole Type: QOM2-VH, 2-pole Type: QDL, 2-polec Rating Catalog Number Price (DE3A) Catalog Number Price (DE3A) Catalog Number Price (DE2A) a 50 QOM50VHb $ 93.00 ... ... ... ... 60 QOM60VH 93.00 ... ... ... ... 70 QOM70VH 93.00 ... ... QDL22070 $762.00 80 QOM80VH 134.00 ... ... QDL22080 762.00 90 QOM90VH 134.00 ... ... QDL22090 762.00 100 QOM100VH 134.00 QOM2100VH $312.00 QDL22100 762.00 110 QOM110VH 312.00 ... ... QDL22110 762.00 125 QOM125VH 312.00 QOM2125VH 312.00 QDL22125 762.00 150 ... ... QOM2150VH 312.00 QDL22150 762.00 175 ... ... QOM2175VH 312.00 QDL22175 762.00 200 ... ... QOM2200VH 312.00 QDL22200 762.00 225 ... ... QOM2225VH 312.00 ... ... a Do not exceed mains rating of device b Reference National Electrical Code Article 230-79. c For additional interrupting rating circuit breakers, order circuit breaker prefix QBL at 10 kA, QGL at 65 kA or QJL at 100 kA, see page 29. Accessories Accessories Catalog Number Description Generator Kit: Interlocks main service disconnect and generator circuit breaker (order separately). For use on: HOMELINE® CSED Devices RC816F-, RC2040M-, SO2040MQO CSED Devices QC816F-, QC2442MFifth Jaw Kit for: Meter Main Types: C, RC, SC, QC All-In-One Types: SC, SU (100–225 A), QC, RC, SO Bypass (Horn Type) for: Ringless Type Meter Mains and All-In-Ones (100–200 A) Lexan Meter Socket Cover Plate for: Ring and Ringless Type Meter Mains Ring and Ringless Type All-In-Ones Meter Socket Sealing Rings for Ring Type Meter Mains and All-In Ones: Screw Type Aluminum Snap Type Stainless Steel Trim Kit for 2" X 6" stud wall, used with: REVERSE All-In-Ones, SU3040M200R, and SU3040M225R Barrel Lock Kit (Barrel Lock not included), supplied with bracket and mounting screw, refer to listings for where used. Semiflush Flange Kit for: Meter Mains: SC816D150/200C and RC816D200CH All-In-Ones: SC2040M200C Semiflush Flange Kit for: Ring and Ringless Type Meter Mains and All-In-Ones 400 A) Ringless Type Utility Cover for use on: RU3040D400CL, QU12L400CL, and QU816D400CL. Includes one piece meter socket and pull box cover with handles and closing plate. Lug Kit includes (4) lugs, for use with #2 AWG–600 kcmil Al/Cu conductors. Lugs are for standard 2-Hole mounting. Meter Main and All-In-One units supplied with (2) Studs per phase and neutral will accept one lug per phase and neutral Overhead Feed Trough: For use on 400 A ring and ringless type meter mains and All-in-Ones. 3" Conduit Adapter Kit: For use on 400 A ring and ringless type meter mains and All-in-Ones. Price Disc. Sch. $163.00 (DE3A) RCGK2 QCGK3 163.00 5J 12.20 (DE3A) RCHB2 61.00 (DE3A) 29007 6.70 (DE4) 29008W ARP00026 d 13.40 (DE4) 11.70 SU2X6TRIM 177.00 (DE3A) SCBRLLOCK 35.30 (DE3A) SC200F 21.20 (DE3A) FK400 131.00 (DE3A) R400L 177.00 (DE3A) CMELK4d OCK400 91.00 (DE4) 378.00 (DE3A) SU400PVCHA3 8.80 (DE3A) d Order only. Not stocked in PDS. Order Point: Lexington. Catalog Number Description Touch-Up Paint (ASA49 Gray) Ground Bar Kit Meter Mains and All-In-Ones QC, RC, and SC (100–225 A) Filler Plate for: Meter Main Types: QC, CU All-In-One Types: QC Filler Plate for: Meter Main Types: RC, SC All-In-One Types: SC, RC, SU Neutral Lug (#6-2/0) for: Meter Main Types: RC, SC, QC All-In-One Types: SC, SU, QC, RC PK49SP PK15GTA Price Disc. Sch. $26.00 (DE1) 11.40 (DE3A) QOFP 2.40 (DE3A) HOMFP 2.10 (DE3A) LK100AN 7.20 (DE3A) Hubs and Closing Plates Hub Conduit Size Series (inches) Closing Plate for “A” Hub opening 1.00 1.25 1.50 A 2.00 2.50 Adapter plate to allow use of “A” Hubs on “A-L” size hub openings Closing Plate for “A-L” Hub opening 2.00 2.50 3.00 A-L 3.50 4.00 Closing Plate for “B” Hub opening 0.75 1.00 1.25 B 1.50 2.00 2.50 B300 3.00 Catalog Number ACP A100 A125 A150 A200 A250 AAP ACPL A200L e A250L A300L A350L A400L BCAP B075 B100 B125 B150 B200 B250 B300 List Price $ 8.90 22.60 22.60 22.60 31.90 40.40 Disc. Sch. (DE4) (DE4) (DE4) (DE4) (DE4) (DE4) 22.50 (DE4) 12.20 55.00 58.00 74.00 76.00 79.00 2.50 22.20 22.20 22.20 22.20 40.90 68.00 124.00 (DE4) (DE4) (DE4) (DE4) (DE4) (DE4) (DE1A) (DE1A) (DE1A) (DE1A) (DE1A) (DE1A) (DE1A) (DE1A) e Supplied with AAP adapter plate and “A” hub. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE1 DE1A DE2A DE3A DE3D DE4 Discount Schedule 27 LOAD CENTERS Circuit Breakers For use with Meter Mains and All-In-One devices Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Combination Service Entrance Devices Dimensions Class 4119, 4120 www.SquareD.com For the most up-to-date information 21/2" Max “A” Hub “A” Hub “B” Hub 4.60 4.60 4.56 117 117 7.50 116 13.82 19.58 351 Blank End Wall 191 13.46 497 28.25 342 7.44 189 10.70 12.80 718 6.44 8.00 164 203 272 325 18.23 20.79 463 528 A,B C,D,E,F 41.25 E,F,G,H A,B 1048 LOAD CENTERS C,D,E,F A C125RB (Shown) CQRB100 B,C D,F,G A,B Ring Type: CM200S C2M200S (Shown) C4L200S 21/2" Max “A” Hub Ringless Type: RC200S RC2M200S RC2M200SH A,B B,C C,D,F A 4.80 122 SO1020M100S G,H,I,J “A-L” Hub 4.67 3.39 Surface A 21/2" Max “A” Hub 119 86 14.77 C,D,F CU12L400CNc CU12L400CBc QU12L400CLc QU12L400SL 14.37 375 365 14.50 368 B,C CU816D400CBc CU816D400CNc QU816D400CLc QU816D400SL (Shown) 10.04 10.87 255 276 21/2" Max “A” Hub D,F,G B,C C,D,F 10.87 276 25.12 638 25.12 6.95 35.13 638 176 892 14.50 368 A 2 1/2" Max “A” Hub D,F,G D,F,G 21/2" Max “A” Hub or B300 C,D,F SC8L125S (Shown) RC8L125S SC1624M100S SC1624M125S RC1624M100S RC1624M125S C,D,F 14.81 376 C,D,E,F A,B D,E,F,G SC8L125F (Shown) SC1624M100F SC1624M125F A,B,C 819 RC816F100CH RC816F125CH RC816F150C/CH RC816F200C/CH RC12L200C/CH RC2040M125CH RC2040M150CH RC2040M200C/CH 3.40 86 14.62 7.90 371 B,C 201 32.23 C,D,E,F C,D,E,F A,B A A A,B B,C A,B A A,B B,C 14.85 377 QC816F100CH QC816F125C/CH QC816F150C/CH (Shown) QC816F200C/CH QC12L200C/CH QC2442M150CH QC2442M200C/CH SO2040M200S B,C A C,E,F,G,H 21/2" Max “A-L” Hub A,B B,C C,D,E,F SC816D150Cq (Shown) SC816D200Cq SC2040M200Cq RC816D200CHq CL Top Branch Circuit Breaker 31.61 803 27.00 686 21/2" Max “A” Hub 39.60 35.40 7.50 1006 899 Blank End Wall 191 5.80 147 48.00 28.25 1219 718 21.50 546 CL Meter Socket 10.30 B D,F,G 4.40 A B 3.50 C,D,E,F SC816F200F SC12L200F SC2040M125F SC2040M200F (Shown) SC3040M200F SC3040M225F 35.40 C,D 899 SU3040M200R (Shown) SU3040M225R 39.60 1006 a Note 1: Driphood supplied factory-installed and is required for surface mount installation. For semi-flush installation, remove driphood and install flange kit, catalog number: SC200F (order separately). A 112 89 B B C,E,F,G,H 21/2" Max “A-L” Hub 14.97 380 SC40M200S B,C SC3040M200S B,C “A” Hub or B300 Hub 8.00 262 282 749 41.25 820 1048 37.30 947 A C,D,E,F C,E,F,G,H 21/2" Max “A-L” Hub “A” Hub B,C A B 7.14 181 28.28 718 C,D,F G,H,I,J “A-L” Hub SC12L200S SC816F150S SC816F200S SC40M200S SC2040M200S (Shown) SC3040M200S C,D,F B,C SU3040D400CBc (Shown) RU3040D400CLc SU3040D300CBc RU3040D400CKc SU3040D400CNc Knockouts B,C,D A 7.50 191 Semi-Flush End Wall 28 29.50 32.30 Drip Hood b Note 2: Unit supplied with blank top endwall (factoryinstalled) for surface mount installation. For semi-flush installation, install flange kit, catalog number FK400 (order separately). Kit includes replacement top endwall (with knockouts) and flanges. 203 11.10 Symbol A B C D E F G H I J Conduit Size (inches) 1⁄2 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4 © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Enclosed Molded Case Switches, Enclosed GFCI Circuit Breakers, Circuit Breaker Enclosures Class 1131 www.SquareD.com For the most up-to-date information Circuit Breaker Enclosures—UL Listed Enclosed Molded Case Switches—UL Listed 22,000 RMS Symmetrical Ampere Short Circuit Current Rating. Not for use with one pole QO circuit breakers. Circuit breakers not included. Order QO®, QO-GFI, QO AFI, QO-EPD and QO-PL circuit breakers separately from pages 3 and 4. Accepts QO circuit breakers with factory-installed accessories. Order equipment ground bar PK0GTA2, if required. Molded Case Switch Included. Does not provide overcurrent protection. Service Ampere Rating 60 ab General Purpose Catalog No. Rainproof Price QO260NATS Catalog No. $107.00 Box No. See Page 19, 20 Price QO200TR $112.00 Service General Purpose e Rainproof Ampere Rating Catalog No. Price 100 125 QO2100BNF/S QO2125BNF/S $55.00 72.00 100 QO3100BNF/S 99.00 2, 9R c 240 Vac Catalog No. Price Box. No. See Page 19, 20 QO2100BNRB $ 90.00 QO2125BNRB 105.00 13, 10R 18, 13R QO3100BNRB 13, 10R 100 d QO2000NS 184.00 QO2000NRB 225.00 13,10R 120/240 Vac 138.00 240 Vac 10,000 RMS Symmetrical Ampere Short Circuit Current Rating. Circuit breaker not included. Order separately from page 3. Will not accept QO-GFI circuit breaker nor QO circuit breakers with factory-installed accessories. Housing Bracket Description Catalog No. Price Bracket used with QO200TR for stucco, aluminum and vinyl siding. Order quantity multiples of 10. PKHB $2.10 60 a .... .... QO2TR $ 63.00 9R c 240 Vac Enclosed GFCI Circuit Breakers—UL Listed 2-pole, 120/240 Vac, GFCI circuit breaker included, 10,000 AIR Service Ampere Rating 50 Type 3R—Rainproof Catalog No. Price Circuit Breaker Included QOE250GFINM HOME250SPA $352. 315. QO250GFI HOM250GFI Box. No. See Page 20 1NM (Non-metallic) 1R (Metallic) 120/240 Vac QO2000NS QO3100BNF With Cover Removed Q Frame Enclosures and Q Frame Circuit Breakers—UL Listed Enclosure Only g Type 1—General Purpose e Service Catalog No. Price Q22200NS h or Q23225NF/S $117.00 145.00 Circuit Breaker (Order Separately) Type 3R—Rainproof Catalog No. Price Q22200NRBh $253.00 or Q23225NRB 278.00 Box No. See Page 19, 20 19, 11R 20, 12R 2-pole 240 Vac Maximum Q23225NF/S 145.00 Q23225NRB 278.00 10,000 AIR Ampere Rating 20, 12R 3-pole 240 Vac Cat. No. Price 25,000 AIR Cat. No. Price 65,000 AIR Cat. No. 70 80 90 100 110 125 150 175 200 225 QBL22070 $316. QBL22080 316. QBL22090 316. QBL22100 316. QBL22110 316. QBL22125 316. QBL22150 316. QBL22175 316. QBL22200 316. QBL22225 316. QDL22070 $ 762. QGL22070 $1014. QDL22080 762. QGL22080 1014. QDL22090 762. QGL22090 1014. QDL22100 762. QGL22100 1014. QDL22110 762. QGL22110 1014. QDL22125 762. QGL22125 1014. QDL22150 762. QGL22150 1014. QDL22175 762. QGL22175 1014. QDL22200 762. QGL22200 1014. QDL22225 762. QGL22225 1014. 70 80 90 100 110 125 150 175 200 225 QBL32070 QBL32080 QBL32090 QBL32100 QBL32110 QBL32125 QBL32150 QBL32175 QBL32200 QBL32225 QDL32070 QDL32080 QDL32090 QDL32100 QDL32110 QDL32125 QDL32150 QDL32175 QDL32200 QDL32225 832. 832. 832. 832. 832. 832. 832. 832. 832. 832. 1189. 1189. 1189. 1189. 1189. 1189. 1189. 1189. 1189. 1189. QGL32070 QGL32080 QGL32090 QGL32100 QGL32110 QGL32125 QGL32150 QGL32175 QGL32200 QGL32225 100,000 AIR Price 1628. 1628. 1628. 1628. 1628. 1628. 1628. 1628. 1628. 1628. Cat. No. Price QJL22070 QJL22080 QJL22090 QJL22100 QJL22110 QJL22125 QJL22150 QJL22175 QJL22200 QJL22225 $1260. 1260. 1260. 1260. 1260. 1260. 1260. 1260. 1260. 1260. QJL32070j QJL32080j QJL32090j QJL32100j QJL32110j QJL32125j QJL32150j QJL32175j QJL32200j QJL32225j 1864. 1864. 1864. 1864. 1864. 1864. 1864. 1864. 1864. 1864. QOM2 Enclosures and QOM2 Circuit Breakers—UL Listed QOM2 Circuit Breaker (Order Separately) i Enclosure Onlyf Type 1 General Purposee Type 3R Rainproof Price Box No. See Pages 19, 20 Ampere Rating Service Catalog No. QOM22225NF/S $156. QOM22225NRB $293. 22, 16R 100 125 150 175 200 225 QOM2100VH $312. QOM2125VH 312. QOM2150VH 312. QOM2175VH 312. QOM2200VH 312. QOM2225VH 312. Catalog No. Price Catalog No. 2-pole 240 Vac Maximum 22,000 AIR a b c d e f g Price r Not suitable for service equipment. Maximum 10 hp 240 Vac. Top endwall has no hub opening. Maximum 20 hp 240 Vac. Order F for flush, S for surface. Equipment ground bar kit PKOGTA2 factory-included. Factory-installed groundable neutral assembly includes (2) ground lugs and (2) neutral lugs. Equipment ground kit PKOGTA2 also included. h Accepts 200 A max. 2-pole Q Frame circuit breakers. i Add suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126. j When these 3-pole circuit breakers are mounted in an enclosure, the maximum AIR rating is 65,000 at 240 Vac and 100,000 at 208 Vac. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE2A rDE3A QOM22225NS Q22200NS With Cover With Cover Removed Removed (Order Q Frame circuit breaker separately) Discount Schedule Q23225NF 29 LOAD CENTERS 120/240 Vac Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Surge P R O T E C T I O N Surgebreaker® secondary surge arresters The Surgebreaker secondary surge arrester is available for both QO® and Homeline® load centers. These surge arresters plug onto the load center bus bars like a circuit breaker and provide protection from high voltage surges. The Homeline Surgebreaker surge arrester can be used in Square D All-In-Ones and Meter Mains. Surgebreaker Plus Whole House Surge Protector The Surgebreaker Plus Whole House Surge Protector from Square D is ideal for protecting electrical circuits, multiple telephone lines and multiple TV lines in today’s electronic home. ■ UL listed 1449, 2nd edition. ■ $50,000 Warranty. ■ Suitable for use in service entrance locations: meets requirements of NEC Article 280. ■ Suitable for indoor applications only. ■ LED Status Indicator. ■ Flush or surface mounting. ■ Electrical System - Connects through the main load center. ■ Two coax lines - Master antenna, satellite dish or cable. ■ Four line telephone (Digital/Analog POTS) protection. 30 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Surge Protective Devices TVSS and Surge Arresters Class 6671 www.SquareD.com For the most up-to-date information SURGEBREAKER® PLUS Transient Voltage Surge Suppressor • • • • • • • QO2175SB AC line protection Four line telephone (Digital/Analog POTS) protection Two line coaxial protection Suitable for indoor applications only Flush or surface mounting LED status indicator Modular design Single Phase Three Wire—120/240 Vac Description Catalog Number Price SURGEBREAKER PLUS SDSB1175C $420. SURGEBREAKER Secondary Surge Arrester SDSB1175C Suitable for use in service entrance locations; meets requirements of NEC Article 280. HOM2175SB • • • • SDSA1175 SDSA3650 White • • CULUS Listed secondary surge arresters; QO2175SB also CSA Certified Meet ANSI/IEEE C62.11-1993 QO2175SB for QO® load centers and combination devices, NQOD panelboards HOM2175SB for HOMELINE® load centers and combination devices Plug-on design requires two pole spaces LED indicates operational status Catalog Number Price QO SURGEBREAKER CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. QO2175SB $106. HOMELINE SURGEBREAKER CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. HOM2175SB Description Black Black Black White Black Black One SDSA1175 on 120/240 Vac Circuit 3Ø4W 208Y/120 Vac 480Y/277 Vac 600Y/347 Vac 106. Hard-Wired Secondary Surge Arrester Suitable for use in service entrance locations; meets requirements of NEC Article 280. Black White Black Listed and CSA Certified secondary surge arresters • Meet ANSI/IEEE C62.11-1993 • Suitable for indoor and outdoor applications • LED indicates operational status • White Black Black Black Black White Two SDSA1175 on 208Y/120 Vac Circuit 3Ø4W 240/120 Vac Catalog Number Price SECONDARY SURGE ARRESTER For 1Ø3W systems. 150 Vac phase-to-ground maximum. SDSA1175 a $ 61. SECONDARY SURGE ARRESTER For 3Ø systems. 600 Vac phase-to-ground maximum.b SDSA3650 Description Black White 3Ø3W Grounded B Phase) 240 Vac 480 Vac DE1B 165. a See page 13 for QOSAMK mounting kit for installation in QO load centers. b Do not use on ungrounded systems. Systems must be solidly grounded. Black © 2004 Schneider Electric All Rights Reserved 6/7/04 CULUS Black For additional information, reference Catalog #6671CT9701R2/02. Discount Schedule 31 LOAD CENTERS Suitable for use in service entrance locations; meets requirements of NEC® Article 280, UL Listed 1449, 2nd Edition, and meets ANSI/IEEE C62.41-1991. Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Air Conditioning D I S C O N N E C T Air Conditioning Disconnects No air conditioning electrical protection system is complete without a Square D air conditioning disconnect. Our disconnects are available in a variety of configurations that let you choose the best product for your particular application. These include molded case switch, fused, and non-fused switches. Enclosed Molded Case Switch ■ Cover housing can be removed to provide open access to lugs for easy wiring. ■ 60 A switch rated for 10 hp motors at 240 Vac. ■ Factory installed ground bar is located in front for easy access. ■ Open area for mounting allows plenty of room for power actuated tool. Dimples accommodate nailer. Fusible and Not Fusible Pullout Switches ■ Interior trim cannot be removed unless the pull-out head is completely disengaged or placed in the OFF position. ■ Pull-out head can be replaced in the OFF position. ■ 30 A and 60 A fusible, and 60 A not fusible ratings, up to 10 hp at 240 Vac. 32 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Air Conditioning Disconnects Class 3150 www.SquareD.com For the most up-to-date information Not Fusible Air Conditioning Disconnect—Molded Case Switch Rainproof—UL Listed Service Metallic Ampere Rating a Catalog Number Non-metallic Catalog Number Price QO200TRNM $127.00 Price Max. Hp 2 Wire (Molded Case Switch Included)—240 Vac Maximum QO200TR QO200TR $107.00 10 Housing Bracket Description Catalog No. Price PKHB $2.10 Bracket used with QO200TR for stucco, aluminum and vinyl siding. Order quantity multiples of 10. Not Fusible Air Conditioning Disconnect—Pullout Rainproof—UL Listed Service Metallic Ampere Rating a Non-metallic Max. Hp Catalog Number Price Catalog Number Price UFP222R $113.00 UFP222RNM $127.00 10 ... ... 10 ... ... 10 2 Wire—240 Vac Maximum 60 G/B QO200TRNM 2 Wire—240 Vac Maximum—with 20 A GFI receptacle 60 UFP222RGFI $303.00 G/B GFI Rec. 2 Wire—240 Vac Maximum—with 20 A duplex receptacle 60 UFP222RD $173.00 G/B PKHB Housing Bracket Duplex Rec. Fusible Air Conditioning Disconnect—Pullout Rainproof—UL Listed Service Metallic Ampere Rating b Catalog Number Non-metallic Price Catalog Number Price Max. Hp 2 Wire (Pullout and Fuseholder)—240 Vac Maximum G/B 30 FP221R $107.00 FP221RNM $127.00 3 60 FP222R 107.00 FP222RNM 127.00 10 Note: Suitable for use as service equipment on 120/240 Vac 1Ø3 wire services if used only on a 1Ø2 wire load; and only when the equipment grounding terminal is replaced with ground terminal kit catalog number PK3GTA1. Price $7.60. Box Dimensions FP221R Catalog Number H W D IN mm IN mm IN QO200TR 4.63 117 6.50 165 3.88 mm 98 QO200TRNM 8.75 222 6.50 165 3.88 98 UFP222R 5.25 133 7.50 191 3.25 83 UFP222RNM 8.75 222 6.50 165 3.88 98 FP221R 5.25 133 7.50 191 3.25 83 FP221RNM 8.75 222 6.50 165 3.88 98 FP222R 5.25 133 8.88 225 3.25 83 FP222RNM 8.75 222 6.50 165 3.88 98 a Does not contain overcurrent protection. Suitable for use on systems with up to 10,000 RMS symmetrical amperes available fault current at 240 Vac max when protected by a fuse or circuit breaker rated 60 A or less. b Suitable for use on systems with up to 10,000 RMS symmetrical amperes available fault current at 240 Vac. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE2A Discount Schedule 33 LOAD CENTERS 60 G/B Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz SERVICEPAK® Power Outlet Panels Class 1140 www.SquareD.com For the most up-to-date information LOAD CENTERS For Construction Sites • Provide temporary power at construction sites. • Each receptacle protected by QO-GFI circuit breaker in compliance with NEC® requirements. • Each enclosure is rainproof. • 10,000 RMS symmetrical ampere short circuit current rating. • UL Listed as suitable for use as temporary site service equipment. • Provided with neutral bonding provisions. • Boxes have provisions for type “B’’ hubs to be field-installed. Power Outlet Configuration Service a Mains Ampere Rating 1C 2C 2C 1Ø2W 1Ø2W 1Ø2W 40 40 40 3C 1Ø3W 70 4C 1Ø3W 70 5C 1Ø3W 70 6C 1Ø3W 70 7C 1Ø3W 70 8C 1Ø3W 70 9C 1Ø3W 100 Circuit Breaker (Included) (1) QO120GFI (2) QO120GFI (2) QO120GFI (1) QO120GFI (1) QO230GFI (1) QO120GFI (1) QO220GFI (1) QO120GFI (1) QO250GFI (1) QO120GFI (1) QO250GFI (2) QO120GFI (1) QO220GFI (2) QO120GFI (1) QO250GFI (1) QO120GFI (2) QO250GFI T 1C T T PAK10C1 PAK11C e PAK11C1 1 PAK31CGFI 649. #8–1 #8–1 PAK36C1GFI 649. #8–1 #8–1 PAK51CGFI 649. #8–1 #8–1 T PAK55CGFI 649. #8–1 #8–1 10C PAK72CGFI 882. #8–1 #8–1 882. #8–1 #8–1 1 Main Wire Size AWG d Cu Al $294. #14–6 #12–6 545. #14–6 #12–6 545. #14–6 #12–6 T 4C Price T T 1 1 1 1 1 2 1 2 1 PAK76CGFI 1 2 PAK1004CGFI 1054. 3C T T 5C T T T T 8C T T T 9C T T 11C T T 6C T 7C 1 T 2C Receptacles (Included) b A C D E F 1 2 2 Catalog Number c T T T 12C T #14–1 #12–1 13C 14C For Recreational Vehicle Parks • • • • • Provide electrical power to individual recreational vehicle park sites. Each receptacle protected by appropriate GFI or Standard QO® circuit breaker. All receptacles and circuit breakers included. 10,000 RMS Symmetrical Ampere short circuit current rating. • UL Listed. All enclosures are rainproof. • No neutral bonding provisions. • Loop-feed provisions. Mains Power Outlet Service Ampere Configuration a Rating Circuit Breaker (Included) Receptacles (Included) b A B Catalog Number Price C Main Wire Size AWG/kcmil f Phase and Neutral Cu Al Underground or Overhead Loop-Feed Terminals—Non-Pedestal cg 10C 11C 1Ø2W 1Ø2W 40 40 12C 1Ø2W 50 13C 1Ø2W 75 14C 1Ø3W 100 (1) QO120GFI (2) QO120GFI (1) QO120GFI (1) QO130 (1) QO120GFI (2) QO130 (1) QO120GFI (1) QO250 (1) QO130 1 2 PAK10CTG PAK11CTG $313. 530. 1 1 PAK41CTG h 376. 1 2 PAK61CTG h 435. 1 1 PAK75CTG (Not Loop Feed) h 446. 1 #14–6 #14–1 a b c d e f g h i j 1Ø2W 40 12C 1Ø2W 50 13C 1Ø2W 75 14C 1Ø3W 100 (2) QO120GFI (1) QO120GFI (1) QO130 (1) QO120GFI (2) QO130 (1) QO120GFI (1) QO250 (1) QO130 2 PAK11PG #12–1 $690. 1 1 PAK41PG h 568. 1 2 PAK61PG h 609. (2)#6–250 (2)#6–250 1 1 PAK75PG h 671. 1 20 Amp 125 Volt 2W and Grd. NEMA 5-20R B 30 Amp 125 Volt 2W and Grd. ANSI #73.13 C 50 Amp 125/250 Volt 3W and Grd. NEMA 14-50R D 20 Amp 250 Volt 2W and Grd. NEMA 6-20R E 30 Amp 125/250 Volt 3W and Grd. NEMA 14-30R F 50 Amp 250 Volt 2W and Grd. NEMA 6-50R #12–6 Pedestal Mounted—Underground Loop-Feed Terminals ij 11C A All non-pedestal devices have provisions to field-install a Type “B’’ hub on the bottom endwall for bottom feed from a conduit riser. Order Type “B’’ bolt-on hub (B250 Max.) and two mounting screws (Part No. 8002505501) and two hex nuts (Part No. 2340102000). (1Ø2W 120 Vac) (1Ø3W 120/240 Vac) 20 ampere receptacles protected by 20 ampere GFI circuit breaker. Devices have a bolt-on factory-installed closing cap. Order type "B’’ bolt-on hub separately from page 20. Equipment Ground Terminal suitable for (2) #14 or 12 AWG Cu or (2) #12 or 10 AWG Al. Receptacles in this device are in bottom endwall and are accessible with outer door padlocked. "Order Only’’ from Lexington—Minimum order quantity is 50 devices. Two wires each per phase, neutral, and equipment ground—for loop feed (except PAK75CTG). Equipment ground terminal suitable for (2) #14–12 AWG Cu or (2) #12–10 Al. GFI circuit breaker can be substituted for standard 30 A circuit breaker. For 30 ampere receptacles add $140.00 per circuit breaker. Add suffix "FI’’ to catalog number. Example: PAK41CTGFI. Stabilizer foot available for use in unstable ground, order catalog number HNPSF $27.50 list. Equipment ground terminals suitable for (2) #10–2/0 AWG Cu or (2) #6–2/0 AWG Al. 34 DE4 Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Structured Wiring A N E W O P P O R T U N I T Y T O I N C R E A S E S A L E S P E R Y O U R H O M E The Square D Multi-Link Structured Wiring System devices organize the way a house is wired to coordinate telephone, video, and data services for unmatched flexibility and convenience. Installed during construction, these devices increase capabilities without adding significant cost to the home. Pre-wiring with standard Cat-5 and RG-6 cables will ensure that the home is wired to meet the demands of today and the future innovations of tomorrow. Square D Multi-Link Structured Wiring System provide the enclosures and brackets to install the video, voice, audio and data hubs along with the accessories and upgrade options to bring the home into the telecommunication and entertainment future. Application: ■ Residential and light commercial ■ New multi-family and single-family construction Standards: ■ UL 1492, Audio/Video Products and Accessories ■ UL 514A, Metallic Outlet Boxes ■ UL 1863, Communications Circuit Accessories ■ Federal Regulation 47CFR15.115 ■ TIA/EIA 570-A, Residential Telecommunications Cabling Standard Enclosures: ■ NEMA Type 1 ■ Surface or flush mount Construction: ■ Modules mount on enclosure grid via “hook and swing” method ■ All modules incorporate a metal backplate for strength and rigidity ■ Data and telephone modules available with either 110 punch down terminations or RJ-45 modular plugs Accessories: AC power accessories, universal adapter brackets, patch cords, cover lock kit, video attenuators, low pass filters. 35 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Square D Multi-Link Structured Wiring System Class 1400 www.SquareD.com For the most up-to-date information The Square D Multi-Link Structured Wiring System devices organize the way a house is wired to coordinate telephone, video, and data services for unmatched flexibility and convenience. Installed during construction, these devices increase capabilities without adding significant cost to the home. System Components Description Catalog Number Price Grid Mounting Space (IN) Standard Package 10 LOAD CENTERS Mounting Brackets and Enclosures Surface mounting bracket, 6 1/2"w x 10"h, white SDM10BW 15.20 10 Cover for SDM10BW, white SDM10CW $ 28.60 ... 1 Enclosure w/mounting grid, 14"w x 18"h, white SDM18BW 44.60 34a 1 Cover for SDM18BW, white SDM18CW 16.30 ... 1 Enclosure w/mounting grid, 14"w x 36"h, white SDM36BW 86.00 70b 1 Cover for SDM36BW, white SDM36CW 28.00 ... 1 Combo hub, video splitter (1 input x 4 TVs) / phone (2 lines x 6 phones), grid mount SDM26P14V 58.00 3 1 Combo hub, video splitter (1 input x 4 TVs) / phone (4 lines x 6 phones), grid mount SDM46P14V 77.00 3 1 SDM46P 1 Combination Video/Telephone Hubs SDM18CW and SDM18BW Telephone Hubs Telephone master hub, 4 lines x 6 phones, grid mount 58.00 3 Telephone expansion hub, 4 lines x 8 phones, grid mount SDM48PX 58.00 3 1 Telephone interface hub, 4 lines x 11 phones, grid mount, RJ45 jacks 74.00 3 1 SDM412PJ Video Hubs SDM46P14V Video splitter, (1 input x 3 TVs), grid mount SDM13VS 19.10 2 1 Video splitter, (1 input x 4 TVs), grid mount SDM14VS 22.90 2 1 Video splitter, (1 input x 8 TVs), grid mount SDM18VS 42.00 2 1 Video amplifier hub (1 input x 6 TVs), bi-directional CATV or antenna, grid mount, 120 Vac power supply included SDM16VAB 96.00 3 1 Video amplifier hub (3 inputs x 8 TVs), bi-directional CATV, IR repeating system, grid mount, 120 Vac power supply included SDM38VBIR 286.00 2.5 1 Video amplifier hub (3 inputs x 8 TVs), CATV or antenna, IR repeating system, grid mount, 120 Vac power supply included SDM38VHIR 286.00 2.5 1 Single channel modulator, RCA inputs, grid mount, 120 Vac power supply included SDM11VM 248.00 2.5 1 Single channel combination modulator, amplifier. Cat-5 input for modulation, combined with amplified coax input for bi-directional CATV, grid mount, 120 Vac power supply included SDM11VMB 286.00 2.5 1 Single channel combination modulator, amplifier. Cat-5 input for modulation, combined with amplified coax input for CATV or antenna, grid mount, 120 Vac power supply included SDM11VMH 286.00 2.5 1 Set top mount dual channel modulator, RCA inputs, IR repeating system, 120 Vac power supply included SDM21VT 372.00 ... 1 Set top mount quad channel modulator, RCA inputs, IR repeating system, 120 Vac power supply included SDM41VT 563.00 ... 1 Set top mount dual channel MTS stereo modulator, RCA inputs, IR repeating system, 120 Vac power supply included SDM21VTST 667.00 ... 1 Set top mount quad channel MTS stereo modulator, RCA inputs, IR repeating system, 120 Vac power supply included SDM41VTST 1122.00 ... 1 Modulator combiner hub (8 input x 1 output), grid mount, use with Video Hub SDM38VHIR/SDM38VBIR, 120 Vac power supply included SDM81VC 172.00 2.5 1 Cat-5 Video Wall Plate, use with SDM11VMB/ SDM11VMH if modulating from a source with RCA outputs SDM1VWP 67.00 ... 1 133.00 2.5 1 63.00 3 1 Modulators SDM46P SDM38VBIR/SDM38VHIR Satellite Hub Satellite TV multi-switch, connects 4 satellite receivers to a dual LNB dish, grid mount SDM11VMH/SDM11VMB SDM24VD Audio Hub Speaker distributon hub (stereo), distributes 1 audio source to six rooms, grid mount SDM16A a Two columns of grid mounting space, 17" of space per column. b Two columns of grid mounting space, 35" of space per column. For additional information, reference Catalog #1400CT0101R3/03. 36 DE7 Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz www.SquareD.com Square D Multi-Link Structured Wiring System Class 1400 For the most up-to-date information System Components, continued Description Catalog Number Price Grid Mounting Standard Space Package (IN) SDM8D Data termination hub provides termination point for Cat-5 wiring, 100 Base-T certified, 8 bridgeable circuits SDM8D (8 - 110 punch down blocks connected to 8 - RJ-45 jacks) $ 67.00 3 1 Data termination hub provides termination point for Cat-5 wiring, 100 Base-T certified, 16 bridgeable circuits (16 110 punch down blocks connected to 8 - RJ-45 jacks) SDM8DB 87.00 4.5 1 Ethernet hub, 10 Base-T certified, 5 - RJ-45 ports, uplink port, grid mount, 120 Vac power supply included SDM5DE 114.00 4 1 Router hub, 10/100 Base-T certified, 7 - RJ-45 ports, grid mount, integral 120 Vac power supply SDM7DR 374.00 14a 1 B&W, single gang in-wall, 0.3 lux, fixed aim, used with and powered by SDM11VMB/SDM11VMH modulator via Cat-5 wiring SDM1VC 229.00 ... 1 Color, single gang in-wall, 6 lux, fixed aim, used with and powered by SDM11VMB/SDM11VMH modulator via Cat-5 wiring SDM1VCC 457.00 ... 1 B&W, double gang in-wall, 2 lux, adjustable aim, used with and powered by SDM11VMB/SDM11VMH modulator via Cat-5 wiring SDM2VC 343.00 ... 1 Color, double gang in-wall, 8 lux, adjustable aim, used with and powered by SDM11VMB/SDM11VMH modulator via Cat-5 wiring SDM2VCC 533.00 ... 1 IR remote control target, coaxial in/out, locate at television SDM1VIR 82.00 ... 1 IR remote control emitter, locate at video source SDM2VIR 20.40 ... 1 White wall plate 4 phone and 2 video SDM10PVWPW 19.70 ... 10 White wall plate 1 data, 2 phone and 2 video SDM10DPVWPW 17.40 ... 10 Almond wall plate 4 phone and 2 video SDM10PVWPA 19.70 ... 10 Almond wall plate 1 data, 2 phone and 2 video SDM10DPVWPA 17.40 ... 10 Ivory wall plate 4 phone and 2 video SDM10PVWPI 19.70 ... 10 Ivory wall plate 1 data, 2 phone and 2 video SDM10DPVWPI 17.40 ... 10 AC outlet accessory, mounts in enclosures, 2 duplex receptacles (not included) accepts 2 power supplies, UL Listed, 120 Vac SDM4AC 30.50 5.5 1 AC outlet accessory, mounts in enclosures, 4 duplex receptacles (not included) accepts 4 power supplies, UL Listed, 120 Vac SDM8AC 36.50 11b 1 Adapter bracket to mount ChannelPlus 3400 or 8200 on Square D Multi-Link grid SDM1A 19.10 2 1 Adapter bracket to mount RJ and type F connectors on Square D Multi-Link grid SDM6A 19.10 2 1 Wire Spacer Mezzanine, Universal Grid, lifts modules 1" above grid, providing wire management capabilities, 11.2"h x 6.5"w SDM12WS 29.20 12 1 Universal heavy duty isolation mounting bracket for nonSquare D Multi-Link products. Load rated 60 pounds. SDM1IMB 58.00 c 1 Universal light duty isolation mounting bracket for nonSquare D Multi-Link products. Load rated 10 pounds. SDM2IMB 28.60 c 1 7.70 ... 1 LOAD CENTERS Data Hubs Video Cameras SDM2VC/SDM2VCC IR Controls Wall Plates SDM1VC/SDM1VCC Accessories SDM18BW with optional modules Patch Cord 1 foot length, Cat-5, RJ-45 plugs on both ends SDM1DC Patch Cord 2 foot length, Cat-5, RJ-45 plugs on both ends SDM2DC 9.60 ... 1 Enclosure Coupling Tube for stacking enclosures, 2 inch conduit SDM2C 15.20 ... 1 Plastic grommet for 2" enclosure knockout, (5) pack SDM2G 2.90 ... 1 Cover Lock Kit SDMLK 29.20 ... 1 Replacement snap locks, lock Square D Multi-Link modules to grid, black (10) pack SDM10SL 11.40 ... 1 Attenuator, 3 dB SDM2503 2.70 ... 10 Attenuator, 6 dB SDM2506 2.70 ... 10 Low Pass Filter, Channel 91 SDM600LPF 38.90 ... 1 a Requires 7" of grid mounting space per column, 14" total. b Requires 5.5" of grid mounting space per column, 11" total. c Space required is dependent upon size of the device utilizing the mounting bracket. For additional information, reference Catalog #1400CT0101R3/03. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE7 Discount Schedule 37 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering T H E W I D E S T S E L E C T I O N I N T H E I N D U S T R Y Metering Equipment Schneider Electric provides the most reliable and most versatile line of metering equipment in the industry for residential and commercial applications. As fewer utilities provide meter sockets it’s important to have one reliable source that meets all your needs. From individual meter sockets to multi-metering centers there’s no better choice than Square D. ■ Individual and Horizontal ganged meter sockets ■ Meter-Pak and EZ Meter-Pak multi-metering equipment Individual Meter Sockets Square D individual meter sockets have provisions to feed a downstream main lug load center (with a maximum of 6 service disconnects), main breaker load center, or an individually enclosed service disconnect. 400 ampere, studs only units have provisions for mounting dual load side lugs to feed two downstream main breaker load centers or two individually enclosed disconnects. EZ Meter-Pak® Multi-Metering Equipment These exclusive Square D Meter Centers not only make it easier to install multi-unit metering equipment, but also provide a more economical option than separately purchasing individual meter sockets. EZ Meter-Pak meter center enclosures meet NEC wire bending requirements, and are designed for wall mounting only (not suitable for floor mounting). All unmetered conductor compartments are sealable by the utility company. 38 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering Individual Meter Sockets Class 4131 www.SquareD.com For the most up-to-date information Individual Meter Sockets—Ring and Ringless Type • Available single or three phase, 600 Vac max., with and without horn or lever bypass, overhead and underground service feed. • 10,000 RMS symmetrical amperes short circuit current rating (or higher with utility approval). • UL Listed, NEMA 3R enclosure. • Units supplied with bonded neutral. • Units supplied with hub opening in top endwall require the use of a bolt-on hub, or closing plate. • Units supplied with solid top are for underground feed only. • Accessories, refer to page 40. This metering is generally utility specific. Always check with local utility company before installing. Contact your nearest Square D/Schneider Electric sales office for additional catalog numbers, if required by utility. Lug Wire Range (Al/Cu) UTRS101B Ampere Jaw Rating (Cont.) Qty. Service Type Catalog Number a Line, Load, and Neutral (AWG/kcmil) Price Wire Binding Enclosure Information Top Endwall Conf. Gnd. (AWG) Box No. see page 41 Material Hub Openingb Closing Plate b #14–2 #14–2 #14–2 #14–2 #14–2 Steel Steel Aluminum Steel Steel Solid Topd Series A Series A Series A Series A ... ACP ACPA ACP ACP 1R 1R 1R 1R 1R #14–2 #14–2 #14–2 #14–2 #14–2 #14–2 Steel Aluminum Steel Steel Aluminum Steel Series A Series A Solid Topd Series A Series A (2)Series A ACP ACPA ... ACP ACPA (2)ACPg 3R 3R 5R 5R 5R 7R Ringless Type, 1-Phase, 3-Wire 600 Vac Max., Without Bypass or Jaw Release 125 125 125 125 125 4 4 4 4 5 UG OH OH OH OH/UG UTZRS101Ad UTRS101B UATRS101B URS101BCPL 1003880Ae 200 200 200 200 200 200 4 4 4 4 4 4 OH OH UG OH/UG OH/UG OH/UG UTRS202B UATRS202B UTRS213Ad UTRS213Be UATRS213Be U92197CCCPL g $ 82.00 82.00 91.00 90.00 107.00 #8–2/0 #8–2/0 #8–2/0 #8–2/0 #8–2/0 118.00 130.00 141.00 141.00 150.00 160.00 #8–250 #8–250 #1/0–350 #1/0–350 #1/0–350 #1/0–350 1 /2" HEX SLOTTED SLOTTED SLOTTED SLOTTED 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" HEX HEX HEX HEX HEX HEX UTRS202B (cover not shown) 125 125 125 125 4 5 4 5 OH/UG OH OH OH/UG UHTRS101B UGHTRS101Lc URS101BDQh UGHTRS111Cf 107.00 107.00 92.00 138.00 #8–2/0 #8–2/0 #8–2/0 #8–2/0 200 200 200 200 200 200 4 4 4 4 4 4 OH/UG OH OH/UG OH/UG UG UG UBHMRS212Be UHTRS202B UHTRS212Be UHTRS213Be UHTRS223Ad URS212ADQdh 140.00 137.00 137.00 142.00 181.00 135.00 #8–250 #8–250 #8–250 #1/0–350 #1/0–350 #8–250 SLOTTED SLOTTED 1/2" HEX SLOTTED 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" HEX HEX HEX HEX HEX HEX #14–2 #14–2 None #14–2 Steel Steel Steel Steel Series A A125c Series A Series A ACP ... ACP ACPf 1R 1R 1R 4R None #14–2 #14–2 #14–2 #14–2 None Steel Steel Steel Steel Steel Steel Series A Series A Series A Series A Solid Topd Solid Top ACP ACP ACP ACP ... ... 4R 3R 4R 5R 2R 4R Ringless Type, 1-Phase, 3-Wire 600 Vac Max., With Lever Bypass and Jaw Release 200 200 200 200 320 4 4 5 5 4 OH OH/UG OH OH/UG OH/UG UTH4203T UTH4213Te UTH5203T UTH5213Te UTH4330Tei 310.00 319.00 329.00 376.00 499.00 #6–350 #6–350 1/2" 1/2" HEX HEX #14–2 #14–2 Steel Steel Series A-L Series A-L ACPL ACPL 8R 9R #6–350 #6–350 1/2" 1/2" HEX HEX #14–2 #14–2 Steel Steel Series A-L Series A-L ACPL ACPL 8R 9R dia. studs #14–1/0 Steel Series A-L ACPL 11R Studs Only 3/8" Ringless Type, 3-Phase, 4-Wire 600 Vac Max., With Lever Bypass and Jaw Release 200 7 OH/UG UTH7213Te 444.00 #6–350 320 7 OH UTH7300Ti 553.00 Studs Only 1/2" 3/8" HEX #14–2 Steel Series A-L ACPL 9R dia. studs #14–1/0 Steel Series A-L ACPL 10R Steel Series A-L ACPL 12R Aluminum Series A-L ACPLA 12R Ringless Type, 3-Phase, 4-Wire 600 Vac Max., Bolt-On Socket Without Bypass UTH5203T (cover not shown) 400 400 7 7 OH/UG OH/UG UK7T ei UAK7T ei 1615.00 1785.00 Studs Only 1/2–20" dia. studs 1/2–20" dia. studs Studs Only 1/2–20" 1/2–20" dia. studs dia. studs Ring Type, 1-Phase, 3-Wire 600 Vac Max., Without Bypass or Jaw Release a b c d e f g h i j 125 4 OH/UG URTRS101Bej $ 82.00 200 4 OH/UG URTRS213Bej 141.00 #8–2/0 #1/0–350 SLOTTED 1/2" HEX #14–2 Steel Series A ACP 1R #14–2 Steel Series A ACP 5R Device requires approval from the serving utility, consult your nearest Square D/Schneider Electric sales office. Order appropriate bolt-on hub or closing plate separately and install on TOP endwall. Device supplied with 1-1/4" bolt-on hub (Cat.No. A125) mounted on TOP endwall. Device supplied with solid top endwall (without hub opening). When unit is installed for underground feed, the appropriate closing plate must be ordered separately and installed over hub opening in TOP endwall of device. Device supplied with closing plate (Cat. No. ACP) mounted on TOP endwall. Device supplied with two closing plates (Cat. No. ACP) mounted in TOP endwall. Contains “Duquesne Light Co.” approved label. Order lugs separately, refer to accessories, page 40. Device supplied with stainless steel, snap-on sealing ring. URTRS213B © 2004 Schneider Electric All Rights Reserved 6/7/04 DE4 Discount Schedule 39 METERING EQUIPMENT Ringless Type, 1-Phase, 3-Wire 600 Vac Max., With Horn Bypass, Without Jaw Release Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering Ganged and Test Block Sockets and Accessories Class 4131 www.SquareD.com For the most up-to-date information Horizontal Ganged Meter Sockets • Single phase, 600 Vac max., main lugs only, 2 through 6 meter positions, with and without horn or lever bypass, end or center feed, overhead and underground service feeds • 10,000 RMS symmetrical amperes short circuit current rating (or higher with utility approval) • UL Listed, NEMA 3R enclosure • Supplied with ground lugs UT2R1121B • Supplied with hub opening in top endwall, requires the use of a bolt-on hub, or closing plate This metering is generally utility specific. Always check with local utility company before installing. Contact your nearest Square D/Schneider Electric sales office for additional catalog numbers, if required by utility. Ringless Type, 1-Phase, 3-Wire, 600 Vac Max., Without Bypass or Jaw Release Branch Ratings Amperes (cont.) Number of Positions Socket Jaw Qty.b Service Type 100 2 3 4 5 6 4 OH/UG 2 4 200 5 4 OH/UG METERING EQUIPMENT 6 Top Endwalla Main Lugs Branch Lugs Phase & Neutral Phase & Neutral Hub Type Closing Plate Al/Cu (Order (Order Al/Cu (AWG) (AWG/kcmil) Separately) Separately) Mains Rating Catalog Number Price 200 205 205 250 300 UT2R1121B UT3R1121B UT4R1131B UT5R1131B UT6R1131Bc $ 302. 373. 440. 605. 771. 205 360 UT2R2122B UT4R2352Tc 431. 737. #6–250 #1/0–500 500 UT5R2392TU 922. #1/0–500 or (2)#1/0–350 1032. #1/0–500 or (2)#1/0–350 620 UT6R2392TU #6–250 #6–250 #6–350 #6–350 #6–350 #8–2/0 #8–250 Box No. See page 41 Series A ACP 13R 13R1 14R 15R 16R Series A Series A-L ACP ACPL 17R 18R Series A-L ACPL 19R Series A-L ACPL 20R a For Hubs and Closing Plates, see Accessories table below. b Fifth Jaw Kit available to convert 4-Jaw Socket to a 5-Jaw Socket. See Accessories table below. c For 120/240 Volt, Three-Wire, Single Phase Dwelling services see NEC Table 310-16 Note 3. Meter Sockets Accessories Description FIFTH JAW KIT Converts a 4-jaw meter socket to a 5-jaw meter socket. For use on meter sockets supplied without lever bypass or jaw release only. CLOSING PLATES (to seal hub openings) For Series A (steel) For Series A (aluminum) For Series A-L (steel) For Series A-L (aluminum) EMT3225CB Surface Mount, Ring Type, Meter Main with Test Block Bypass (Meets EUSERC Requirements) Supplied with bondable neutral, suitable for use as service equipment. Suitable for overhead or underground service. UL Listed File E6294. System (Incoming) and Service (Outgoing) 120/240 Vac 1Ø3W 208Y/120 Vac 3Ø4W or 240/120 Vac 3Ø4W Delta Meter Ampere Socket Rating Type (Max.) 5-Jaw 7-Jaw 200 A 200 A Short Circuit Current Rating Catalog Numberf 42k Max. EMT1225CB 22k Max. EMT3225CB Price Main Circuit Breaker Type (Order Separately)d $2730. 2-pole, Type QB, QD, QG, QJ, QOe, QO-VHe or QOHe 3570. 3-pole, Type QB, QD, QG or QJ 22.60 22.60 22.60 31.90 40.40 A200L A250L A300L A350L A400L 55.00 58.00 74.00 76.00 79.00 B300 124.00u AAP 22.50 Includes one, two-barrel lug (#6-250 kcmil) ARP00118h 25.40 Includes one, single barrel lug (#4-600 kcmil) ARP00129h 36.80 Includes three, two-barrel lugs (#6-350 kcmil) ARP00427h 90.00 ARP00026h 29008G 29008W 11.10 13.40 13.40 ADAPTER PLATE To allow the use of a Series A Hub on a device that is setup for a series A-L Hub. LUG KITS For use on meter sockets supplied with Line, Load, and Neutral Studs only. Be sure to order enough lugs for each device (a typical 1-Phase device requires 6 lugs). EMT Terminal Datag h Order only. Not stocked in PDS. Order point: Lexington. Service Ground Lug Wire Size (AWG-kcmil) Equipment Ground Lug Wire Size (AWG-kcmil) Load Neutral Lug Wire Size (AWG-kcmil) #6–300 Al/Cu #6–350 Al/Cu #4–300 Al/Cu #6–300 Al/Cu #4–300 Al/Cu 9.90 A100 A125 A150 A200 A250 d Refer to page 50 to select main circuit breaker. e Requires use of EZM125QOA adapter (order separately). Refer to page 50 for pricing. f Refer to page 41 for box dimensions. Line Neutral Lug Wire Size (AWG-kcmil) $ 8.90 7.90 12.20 11.00 SEALING RING (Non-Standard) Snap-on Stainless Steel Latch-Type Stainless Steel Screw Type Aluminum Line Phase Lug Wire Size (AWG-kcmil) A5J Price ACP ACPA ACPL ACPLA HUBS (listed by conduit size) Series A: 1.00 inch 1.25 inch 1.50 inch 2.00 inch 2.50 inch Series A-L: 2.00 inch 2.50 inch 3.00 inch 3.50 inch 4.00 inch Series B: 3.00 inch EMT3225CB Without Covers Catalog Number g Refer to circuit breaker listings for usable load lug wire sizes. 40 uDE1A DE4 Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering Individual, Ganged and Test Block Sockets Dimensions www.SquareD.com For the most up-to-date information W D Hub Opening Meter Socket D Solid Top Meter Socket Offset H A,B,C,D,E W Knockout Information and Enclosure Dimensions W Hub Opening Meter Socket H H E,F,G S A,B,C,D C,D,E,F A,B,C,D S A 1R D A 2R W D Hub Opening 3R, 6R Hub Opening W Meter Socket Offset Meter Socket D W Hub Opening Meter Socket H C,D,E,F,G S S C,D,E,F,G F,G,H H D,E,F,G A,B A S A H F,G,H A,B S F,G,H D,E,F,G W D Hub Opening 8R W D Hub Opening H F,G,H S H F,G,H,I A,B A A S F,G,H F,G,H,I 9R 10R W D Hub Opening (Max. Conduit Size)a 1R 2R 3R 4R 5R 6R 7R 10.88 13.00 14.00 14.00 15.00 15.50 17.13 8.00 13.00 8.00 11.00 11.00 8.00 13.00 3.50 4.94 4.38 4.38 4.38 4.36 4.94 Series A Solid Top Series A Series A Series A Series A (2) Series A 8R 9R 10R 11R 19.00 19.00 34.50 36.62 10.50 13.00 15.00 15.00 4.94 4.94 5.68 5.68 Series A-L Series A-L Series A-L Series A-L 12R 43.00 20.25 6.00 Series A-L 13R 13R1 14R 15R 16R 14.12 14.12 14.12 14.12 14.12 24.31 32.50 40.62 48.75 57.00 4.50 4.50 4.50 4.50 4.50 Series A Series A Series A Series A Series A 17R 18R 19R 20R 14.12 14.12 14.12 14.12 24.31 40.62 54.75 63.00 5.38 5.38 5.38 5.38 Series A Series A-L (2) Series A-L (2) Series A-L Hub Opening H F,G,H,I A H a Refer to page 40 for closing plates and hubs. W Meter Socket Offset Meter Socket Meter Socket A,B F,G,H 7R 4R, 5R D A Dimensions (Inches) Box No. Knockouts Symbol S A B C Conduit Size (inches) 5⁄16 b 1⁄2 3⁄4 1 D E 11⁄4 11⁄2 W Meter Socket 2 21⁄2 3 31⁄2 4 C,D,E,F,G (13R, 17R) W D Main Lugs S Meter Socket H Main Lugs S A C,D,E,F,G (13R) F,G,H (17R) C,D,E,F,G (13R, 17R) C,D,E,F,G (14R, 18R) H A C,D,E,F,G (14R) F,G,H (18R) 13R and 17R 12R J Hub Opening W H A,B I 11R Meter Socket G,H,I,J H F,G,H,I D Hub Opening G b Knockout for ground conductor. S Hub Opening D F METERING EQUIPMENT D C,D,E,F,G (14R, 18R) 14R and 18R Hub Opening W D Meter Socket Main Lugs S C,D,E,F,G H D Meter Socket Left position omitted on 5-Gang unit (15R) W Hub Opening A C,D,E,F,G Main Lugs C,D,E,F,G S 13R1 7.50 191 22.44 570 Supplied with (2) ACP Closing Plates. Order A-Hubs separately for overhead service feed. C,D,E,F,G H A C,D,E,F,G C,D,E,F,G 15R and 16R D Meter Socket Left position omitted on 5-Gang unit (19R) W Hub Opening 40.00 1016 C,D,E (3 Locations) Main Lugs E,F,G,H (8 Locations) S A,B C,D,E,F,G (19R, 20R) H A F,G,H (19R, 20R) C,D,E,F,G (19R, 20R) 19R and 20R EMT1200CB and EMT3200CB © 2004 Schneider Electric All Rights Reserved 6/7/04 41 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering MP METER-PAK™ Meter Centers Class 4141 www.SquareD.com For the most up-to-date information Ring and Ringless Type Devices • • • • • • • • • • • • • Consult local utility for approval before installation. 120/240 Vac 1 Phase 3 Wire. Main lugs only—two to six meter sockets. Enclosures are indoor/rainproof NEMA 3R construction. Suitable only for use as service equipment. Swingable mounting feet supplied at bottom of device. Factory installed mechanical lugs, alternate lugs and NEMA/EUSERC lug landing kits available. Surface mount, convertible to semi-flush with field installed flange kit. Ring type devices supplied with 4-jaw meter sockets (5th jaw kits available, order separately). Ringless type devices supplied with 5-jaw meter sockets, available with and without horn or lever bypass. Provisions for mounting 2-pole circuit breaker for each meter socket position (order circuit breakers separately). Mounting channel supplied, except for box 1R (125 A, 2-position). Combination overhead/underground feed. Step 1: Select Ring or Ringless Type MP METER-PAK Metering Equipment Ring Type MP METER-PAK Metering Equipment with 125 A (42k RMS Symmetrical Amperes Maximum SCCR) or 200 A (22k RMS Symmetrical Amperes Maximum SCCR) Meter Socket Positions Amps per Pos. No. of Pos. 2 METERING EQUIPMENT 125 Factory Installed Main Lug Ampacity (See page 43 for alternate lugs) 200 Main Bus Ampacity Catalog Numberb Price 200 MP22125a $ 651. 3 300 300 MP33125b 791. 4 400 400 MP44125b 1153. 5 500 MP55125b 1386. 6 400 Al 500 Cu 400 Al 500 Cu 600 MP66125b 1610. 2 400 400 MP42200b 849. 3 400 400 MP43200b 1434. 200 4 400 600 MP64200b 1876. 5 6 600 Al, 750 Cu 600 Al, 750 Cu 800 800 MP85200b MP86200b 2251. 2693. Line Lug Wire Size Al/Cu AWG/kcmil (1) 4–250 (1) 1/0–600 or (2) 1/0–250 (1) 1/0–600 or (2) 1/0–250 (1) 1/0–600 or (2) 1/0–250 (1) 1/0–600 or (2) 1/0–250 (1) 1/0–600 or (2) 1/0–250 (1) 1/0–600 or (2) 1/0–250 (1) 1/0–600 or (2) 1/0–250 (2) 3/0–500 (2) 3/0–500 Circuit Breaker Type (2-Pole) QO, QO-VH, QOH QOM2-MM, QOM2-MVH Hub Prov. Semi-Flush Flange Kit Wt Lbs A/B300 MPSF12 46 Box No. (See pg. 44) 1R A-L MPSF14 95 2R A-L MPSF14 97 2R A-L MPSF16 130 3R A-L MPSF16 132 3R MPSF23 99 4R MPSF23 99 4R MPSF24 135 5R MPSF26 MPSF26 173 173 6R 6R A-L a Meets EUSERC standards. b Meets EUSERC standards with addition of lug landing kit, MMSK2. Ringless Type MP METER-PAK Metering Equipment with 125 A (42k RMS Symmetrical Amperes Maximum SCCR) or 200 A Type MPR, MPH (22k RMS Symmetrical Amperes Maximum SCCR) or 225 A Type MPL (100k RMS Symmetrical Amperes Maximum SCCR) Meter Socket Positions Amps No. Per Pos. of Pos. 2 3 125 225 200 300 Horn Bypass Catalog Number Lever Bypass Catalog Number Main Bus Ampacity No. Bypass Catalog Number Price 200 MPR22125 $ 663. MPH22125 $ 668. .... ... 300 MPR33125 813. MPH33125 835. .... ... Price Price 4 400 400 MPR44125 1187. MPH44125 1220. .... ... 5 400 Al 500 Cu 400 Al 500 Cu 400 400 400 300 400 400 600 Al, 750 Cu 600 Al, 750 Cu 500 MPR55125 1497. MPH55125 1553. .... ... 600 MPR66125 1743. MPH66125 1810. .... ... 400 400 600 300 400 600 800 800 MPR42200 MPR43200 MPR64200 ... ... ... MPR85200 MPR86200 860. 1457. 1910. ... ... ... 2363. 2827. 866. 1479. .... 1944. ... MPL32225 ... MPL53225 ... MPL64225 2418. .... 2894. .... 6 200 Factory Installed Main Lugs Ampacity (See page 43 for alternate lugs) 200 2 3 4 2 3 4 5 6 MPH42200 MPH43200 MPH64200 ... ... ... MPH85200 MPH86200 ... $1159. 1827. 2437. ... ... Line Lug Wire Size Al/Cu AWG/kcmil (1) 4–250 (1) 1/0–600 or (2) 1/0–250 (1) 1/0–600 or (2) 1/0–250 (1) 1/0–600 or (2) 1/0–250 (1) 1/0–600 or (2) 1/0–250 Circuit Breaker Type (2-Pole) A/B300 Semi-Flush Flange Kit MPSF12 MPSF14 QO, QO-VH, QOH (1) 1/0–600 or (2) 1/0–250 QOM2-MM, QOM2-MVH (1) 1/0–600 or (2) 1/0–250 QB, QD, QG, QJ, QOe, QO-VHe or QOHe (2) 3/0–500 (2) 3/0–500 Hub Prov. Box Wt No. Lbs (See pg. 44) 46 1R 95 2R MPSF14 97 2R MPSF16 130 3R MPSF16 132 3R MPSF23 MPSF23 MPSF24 N/A N/A N/A MPSF26 MPSF26 99 99 135 105 147 200 173 173 4R 4R 5R 7R 8R 9R 6R 6R A-L A-L QOM2-MM, QOM2-MVH c Requires use of EZM125QOA adapter (order separately). Refer to page 50 for pricing. UL Listed short circuit current rating depends on lowest interrupting rating of circuit breaker installed. (See page 43) For additional information, reference Catalog #4100CT9801. 42 DE4 Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering MP METER-PAK™ Meter Centers Tenant Circuit Breakers & Accessories www.SquareD.com For the most up-to-date information Step 2: Select Tenant Circuit Breakers 10,000 AIR 120/240 Vac Amps Price u 22,000 AIR 120/240 Vac Price u 42,000 AIR 120/240 Vac Price u 100,000 AIR 120/240 Vac Price u For Use in 125 A Max. Type MP, MPR and MPH METER-PAK Metering Equipment QO2100VH 2-Pole, Plug-on Type Circuit Breaker 60 QO260 $ 44.70 QO260VH $ 97.00 QOH260a $ 211.00 ... ... 70 QO270 89.00 QO270VH 149.00 QOH270a 352.00 ... ... 80 QO280 126.00 QO280VH 210.00 QOH280a 434.00 ... ... 90 QO290 126.00 QO290VH 210.00 QOH290 434.00 ... ... 100 QO2100 126.00 QO2100VH 210.00 QOH2100 434.00 ... ... 125 QO2125 285.00 QO2125VH 689.00 QOH2125 926.00 ... ... For Use in 200 A Max. Type MP, MPR and MPH METER-PAK Metering Equipment 100 QOM2100MM 316.00 QOM2100MVH 762.00 ... ... ... ... 125 QOM2125MM 316.00 QOM2125MVH 762.00 ... ... ... ... 150 QOM2150MM 316.00 QOM2150MVH 762.00 ... ... ... ... 175 QOM2175MM 316.00 QOM2175MVH 762.00 ... ... ... ... 200 QOM2200MM 316.00 QOM2200MVH 762.00 ... ... ... ... 65,000 AIR 120/240 Vac Price u 100,000 AIR 120/240 Vac Price u For Use in 225 A MPL Lever Bypass METER-PAK Metering Equipment QDP22200TM 2-Pole, Bolt-on Type Circuit Breaker a b c d QOM2200MVH Price u 25,000 AIR 120/240 Vac Price u 40 QO240b 44.70 QO240VHbc 97.00 QOH240bd 211.00 ... ... 50 QO250b 44.70 QO250VHbc 97.00 QOH250bd 211.00 ... ... QOH260bd 60 QO260b 44.70 QO260VHbc 97.00 70 QBP22070TM 316.00 QDP22070TM 762.00 QGP22070TM 1014.00 QJP22070TM $1260.00 80 QBP22080TM 316.00 QDP22080TM 762.00 QGP22080TM 1014.00 QJP22080TM 1260.00 90 QBP22090TM 316.00 QDP22090TM 762.00 QGP22090TM 1014.00 QJP22090TM 1260.00 100 QBP22100TM 316.00 QDP22100TM 762.00 QGP22100TM 1014.00 QJP22100TM 1260.00 110 QBP22110TM 316.00 QDP22110TM 762.00 QGP22110TM 1014.00 QJP22110TM 1260.00 125 QBP22125TM 316.00 QDP22125TM 762.00 QGP22125TM 1014.00 QJP22125TM 1260.00 150 QBP22150TM 316.00 QDP22150TM 762.00 QGP22150TM 1014.00 QJP22150TM 1260.00 175 QBP22175TM 316.00 QDP22175TM 762.00 QGP22175TM 1014.00 QJP22175TM 1260.00 200 QBP22200TM 316.00 QDP22200TM 762.00 QGP22200TM 1014.00 QJP22200TM 1260.00 225 QBP22225TM 316.00 QDP22225TM 762.00 QGP22225TM 1014.00 QJP22225TM ... ... 1260.00 Order only. Not stocked in PDS. Order Point: Lincoln. Requires use of EZM125QOA adapter (order separately). Refer to page 50 for pricing. QOVH tenant circuit breakers are rated 22,000 AIR at 120/240 Vac. QOH tenant circuit breakers are rated 42,000 AIR at 120/240 Vac. UL Listed Short Circuit Current Rating depends on lowest interrupting rating of circuit breaker installed. (Refer to the table on the bottom of page 52 for Square D certified ratings for downstream panelboards and load centers.) Accessories Accessories (Continued) Catalog Number Description Fifth Jaw Kit 5J Horn Bypass Kit MMHB Price Description 182.00 11.10 125 A Ring Style 2 Position Top Meter (Only) MM125MBe 114.00 NEMA Lug Landing Kit: For use ONLY on MPL43225 and MPL64200 with optional lugs. See wiring diagram of each device for optional lugs. 125 A/200 A Ring Style MM200MBe 114.00 MP Meter-Pak Wireway: 2920910001 29008W ARP00026 5.00 13.40 11.10 Slider Type Manual Circuit Closing: Sealing Rings: Snap-on Aluminum Screw Type Aluminum Snap-on Type Stainless Steel Meter Cover-Lexan® 29007 Catalog Number NEMA/EUSERC Lug Landing Kit: For 3 through 6 position 125 A and 200 A devices. Each pad rated 600 A maximum MMSK2g and includes (2) 1/2-13 studs and mounting hardware. $ 12.20 QO Adapter for Bolt-on Q2M tenant circuit EZM125QOA breakers (40–125 A, 2-pole) MMLK500 211.00 6.70 Optional Lug Kits: Price $123.00 MMSK4 184.00 125 A 2 Position ONLY MP43X8PED 294.00 125 A 3–6 Position MP43X11PED 336.00 200 A 2–6 Position MP43X11PED 336.00 MPL32-200 MP35X11PEDh 336.00 MPL53-200 MP43X11PED 336.00 MPL64-200 MP35X11PEDh 336.00 (1) 1/0–600 AWG/kcmil or (2) 1/0–250 per phase MMLK250fg 100.00 (2) 3/0–500 AWG/kcmil per phase MMLK500g 133.00 Used ONLY with MP43X8PED MP12X8PEDEXTh 68.00 (2) 2–600 AWG/kcmil per phase MMLK600g 155.00 Used with MP43X11PED & MP35X11PED MP12X11PEDEXTh 84.00 MPSF12 MPSF14 MPSF16 MPSF23 MPSF24 MPSF26 67.00 89.00 145.00 96.00 114.00 170.00 Semiflush Kits: 125 A 2 Position 125 A 3–4 Position 125 A 5–6 Position 200 A 2–3 Position 200 A 4 Position 200 A 5–6 Position MP Meter-Pak Wireway Extensions: e The meter center short circuit current rating is 10,000 amperes RMS symmetrical when manual circuit closing is used. Not rated for continuous duty. f Standard lug for 3 through 6 position 125 A and 2 through 4 position 200 A devices. g Cannot be installed on 2 position 125 A device. h Order only. Not stocked in PDS. Order point: Lexington. See page 40 for hubs and closing plates For additional information, reference Catalog #4100CT9801. © 2004 Schneider Electric All Rights Reserved 6/7/04 u DE2A DE4 Discount Schedule 43 METERING EQUIPMENT 10,000 AIR 120/240 Vac Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering MP METER-PAK™ Meter Centers Dimensions, Knockouts www.SquareD.com For the most up-to-date information A-L Hub Opening Supplied with ACPL Closing Plate A-L Hub Opening Supplied with ACPL Closing Plate 7.28 A Hub Opening Supplied with ACP Closing Plate 185 7.28 185 618 Top Position Omitted on 3-Gang Unit 12.28 Mounting Holes (4) Locations (Supplied without Mounting Channel) 7.28 24.34 185 36.46 926 312 9.00 Top Left Position Omitted on 5-Gang Unit 229 Typ. 37.50 953 9.00 48.12 229 Typ. 1222 9.00 229 42.37 1076 18.50 470 11.19 11.19 C,D,F C,D,F 284 C,D,F E,F,G,H,I,J and A-L Hub Provision C,D,F D,F,G and A or B300 Hub Provision 284 C,D,F C,D,F A,B A Box 1R A A,B Box 2R Box 3R E,F,G,H,I,J and A-L Hub Provision A-L Hub Opening Supplied with ACPL Closing Plate A-L Hub Opening Supplied with ACPL Closing Plate A-L Hub Opening Supplied with ACPL Closing Plate 8.28 210 8.28 8.28 210 210 29.44 METERING EQUIPMENT 748 46.68 29.44 1186 748 Top Position Omitted on 2-Gang Unit Top Left Position Omitted on 5-Gang Unit 9.00 229 Typ. 9.00 9.00 229 Typ. 229 Typ. 52.00 1321 43.41 43.41 1103 1103 12.22 12.22 310 C,D,F 12.22 C,D,F E,F,G,H,I,J and A-L Hub Provision E,F,G,H,I,J and A-L Hub Provision E,F,G,H,I,J and A-L Hub Provision C,D,E,F C,D,E,F C,D,E,F Box 4R 310 C,D,F 310 A,B A,B,C Box 5R A,B Box 6R A-L Hub Opening Supplied with ACPL Closing Plate A-L Hub Opening Supplied with ACPL Closing Plate A-L Hub Opening Supplied with ACPL Closing Plate 9.62 9.62 9.62 244 244 244 35.37 35.37 19.43 898 898 494 53.12 14.00 1349 356 14.00 60.25 67.37 356 Typ. 1530 34.00 1711 14.00 13.43 864 356 Typ. 341 C,D,E,F C,D,E,F 13.43 341 E,F,G,H,I,J and A-L Hub Provision C,D,E,F A,B Box 8R Box 7R 44 C,D,E,F E,F,G,H,I,J and A-L Hub Provision C,D,E,F E,F,G,H,I,J and A-L Hub Provision C,D,E,F A,B Knockouts Symbol A B C Conduit Size (inches) 1⁄2 3⁄4 1 D E 11⁄4 11⁄2 F G H I J 2 21⁄2 3 31⁄2 4 Box 9R A,B © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering EZ METER-PAK® Meter Centers Single Phase—Indoor/Rainproof www.SquareD.com For the most up-to-date information 1Ø3W EZ METER-PAK Meter Centers— UL Listed Select EZM meter center short circuit current rating RMS symmetrical amperes from table on page 53. Using this table as a reference, make the following selections: ➀ Select EZM single phase main device below with an equal or higher short circuit rating than the application. ➁ Select EZM single phase branch units; page 46. ➂ Select proper 2-pole type QO, QO-VH, QOH, QBP-TM, QDP-TM, QGP-TM or QJP-TM branch circuit breakers for use as tenant mains in branch unit; page 50. ➃ Select accessories as required; page 50. ➄ Dimensions; page 51. ➀ Main Devices—NEMA 3R Construction Overhead/Underground Feed System Type Ampere Rating Horizontal Cross Bus Rating and Bus Bar Material Catalog Number Width (Dim. see pg. 51) Price Line Side Lug and Wire Size (AWG–kcmil) Conductor Qty. per Phase and Neutral (Factory Installed) 65,000 RMS Symmetrical Ampere Short Circuit Current Rating Main Circuit Breakers (1Ø Incoming and 1Ø Outgoing) 1Ø3W 120/240 Vac 400 600 800 1000 1200 1600 800 A Al 800 A Al 800 A Al EZM1400CBe EZM1600CBe EZM1800CBe 18.66 $ 4120. 18.66 5715. 18.66 7576. 1000 A Al 1200 A Al/Cu 1200 A Al/Cu EZM11000CBeh EZM11200CBfg EZM11600CBfg 18.66 30.19 30.19 10511. 13577. 19936. (1) #1–600 or (2) #1–250 (3) 3/0–500 (3) 3/0–500 (3) 3/0–500 (4) 1/0–750 (6) 1/0–750 100,000 RMS Symmetrical Ampere Short Circuit Current Rating Main Fusible Switches (1Ø Incoming and 1Ø Outgoing)— Requires 300 Vac Class T Fuses (Order Separately) 1Ø3W 120/240 Vac 400 600 800 1200 800 A Al 800 A Al 800 A Al 1200 A Al/Cu EZM1400FS EZM1600FS EZM1800FS EZM11200FSg 18.66 18.66 18.66 30.19 2659. 4652. 5981. 7709. (1) #1–600 or (2) #1–250 (3) 3/0–500 (3) 3/0–500 (4) 1/0–750 532. 581. 610. 677. (1) 4–300 (1) 4–300 (2) 3/0–500 (2) 3/0–500 Main Lugs Terminal Boxes (1Ø Incoming and 1Ø Outgoing)c 800 A Al 800A Cu 800 A Al 800A Cu EZM1225TB EZM1225TBCU EZM1400TB EZM1400TBCU 11.50 11.50 18.66 18.66 600 600 800 800 800 A Al 800A Cu 800 A Al 800A Cu EZM1600TB EZM1600TBCU EZM1800TB EZM1800TBCU 17.00 17.00 23.93 23.93 665. (1) 350–750 or (2) 1/0–300 810. (1) 350–750 or (2) 1/0–300 824. (4) 3/0–500 1105. (4) 3/0–500 1200 A Al 1200 A Cu EZM11600TBg EZM11600TBCU 22.33 22.33 2392. 2986. 1600 1600 (6) 3/0–600 (6) 3/0–600 METERING EQUIPMENT 1Ø3W 120/240 Vac 225 225 400 400 Underground Feed Only System Type Ampere Rating Horizontal Cross Bus Rating and Bus Bar Material Catalog Number Meets EUSERC Requirements Width (Dim. see pg. 51) Price Factory Installed Lug Landings For Use with Crimp-Type Lugs (2-Hole Mounting) Qty. per Phase and Neutrala 65,000 RMS Symmetrical Ampere Short Circuit Current Rating Main Circuit Breakers (1Ø Incoming and 1Ø Outgoing) 1Ø3W 120/240 Vac EZM1800CB 400 600 800 1000 1200 1600 800 A Al 800 A Al 800 A Al EZM1400CBUe EZM1600CBUe EZM1800CBUe 20.46 $ 4253. 1 (Order Lugs Separately) 20.46 6114. 2 (Order Lugs Separately) 20.46 7841. 2 (Order Lugs Separately) 1000 A Al 1200 A Al/Cu 1200 A Al/Cu EZM11000CBUebh EZM11200CBUegb EZM11600CBUfgd 34.19 34.19 30.19 11031. 3 (Order Lugs Separately) 14221. 3 (Order Lugs Separately) 21105. 6 (Order Lugs Separately) 100,000 RMS Symmetrical Ampere Short Circuit Current Rating Main Circuit Breakers (1Ø Incoming and 1Ø Outgoing) 1Ø3W 120/240 Vac EZM1800CBU 1000 1200 1000 A Al 1200 A Al/Cu EZM11000CBUeh EZM11200CBUeg 34.19 34.19 11031. 3 (Order Lugs Separately) 14221. 3 (Order Lugs Separately) 100,000 RMS Symmetrical Ampere Short Circuit Current Rating Main Fusible Switches (1Ø Incoming and 1Ø Outgoing)— Requires 300 Vac Class T Fuses (Order Separately) 1Ø3W 120/240 Vac 400 600 800 1200 800 A Al 800 A Al 800 A Al 1200 A Al/Cu EZM1400FSU EZM1600FSU EZM1800FSU EZM11200FSUg 20.46 20.46 20.46 34.19 4120. 6246. 7709. 9436. 1 (Order Lugs Separately) 2 (Order Lugs Separately) 2 (Order Lugs Separately) 3 (Order Lugs Separately) Main Lugs Terminal Boxes (1Ø Incoming and 1Ø Outgoing). Supplied with isolated neutral (can not be bonded).c 1Ø3W 120/240 Vac 400 400 800 800 1200 1200 800 A Al 800A Cu 800 A Al 800A Cu EZM1400TBU EZM1400TBUCU EZM1800TBU EZM1800TBUCU 16.16 16.16 24.16 24.16 1029. 1379. 1218. 1633. 1 (Order Lugs Separately) 1 (Order Lugs Separately) 2 (Order Lugs Separately) 2 (Order Lugs Separately) 1200 A Al/Cu 1200 A Cu EZM11200TBUg EZM11200TBUCU 32.16 32.16 2483. 3 (Order Lugs Separately) 3327. 3 (Order Lugs Separately) a For mechanical lugs (3/0 to 600 kcmil) order kit catalog number CMELK4, Price $91.00. Kit includes 4 lugs only. Multiple kits may be required, consult factory. For crimp-type lugs refer to Anderson Electrical Connector Products Catalog AEC-40R. b Has a 100,000 RMS symmetrical ampere short circuit current rating. c Has a maximum 100,000 RMS symmetrical short circuit current rating when protected by Class R (600 A Max.) or Class T (800 A Max.) fuses. For other short circuit current ratings refer to table on page 53. Suitable for use on LINE or LOAD side of service equipment. Use to feed type EZMT branch units for 6-Sub Division Rule applications. d Does not meet EUSERC Standards. Not stocked in PDS, Order only (allow 6 weeks for delivery). Not UL Listed. e Available by special order with main circuit breaker supplied with other standard ampere ratings, consult local Field Office (allow 6 weeks for delivery). f Ampere rating of the PA circuit breaker supplied with this main can be changed it field by ordering a different set of rating columns, refer to Digest 173 page 6-25 for listing. g Supplied with copper horizontal bus bars and aluminum vertical bus bars. h May be end mounted to feed branch units with 800 A or 1200 A horizontal cross bus. For additional information, reference Catalog #4100CT9801. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE4 Discount Schedule 45 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering EZ METER-PAK® Meter Centers Single Phase—Indoor/Rainproof www.SquareD.com For the most up-to-date information 1Ø3W EZ Meter-Pak Meter Centers — UL Listed ② Branch Devices—NEMA 3R Construction Branch Units—1Ø Incoming and 1Ø Outgoing System Type Width (Dim. see pg. 51) Horizontal Cross Bus Rating and Bus Bar Material Number of Meter Sockets Ring Type 4-Jaw Meter Socketa Catalog Number Ringless Type 5-Jaw Meter Socket with Horn Bypass Ringless Type 5-Jaw Meter Socket Catalog Number Price Catalog Number Price Price 125 A Maximum (Order Type QO, QO-VH or QOH Circuit Breakers Separately)f 1Ø3W 120/240 Vac 2-Pole Branch Circuit Breakers 3 800 A Al 800 A Cu EZM113125 EZM113125CU $ 957. 1288. EZMR113125 EZMR113125CU $ 957. 1288. EZMH113125 EZMH113125CU $1170. 1608. 4 800 A Al 800 A Cu EZM114125 EZM114125CU 1276. 1767. EZMR114125 EZMR114125CU 1276. 1767. EZMH114125 EZMH114125CU 1435. 2007. 5 800 A Al 800 A Cu EZM115125 EZM115125CU 1569. 2206. EZMR115125 EZMR115125CU 1569. 2206. EZMH115125 EZMH115125CU 1940. 2764. 6 800 A Al 800 A Cu EZM116125 EZM116125CU 1861. 2644. EZMR116125 EZMR116125CU 1861. 2644. EZMH116125 EZMH116125CU 2366. 3402. 12.25 EZMH114125 225 A Maximum Branch Units (Order Type QB, QD, QG or QJ Circuit Breakers Separately)fi 1Ø3W 120/240 Vac 2-Pole Branch Circuit Breakers 2 800 A Al 800 A Cu EZM112225 EZM112225CU 1515. 2126. EZMR112225 EZMR112225CU 1515. 2126. EZMH112225 EZMH112225CU 1649. 2326. 3 800 A Al 800 A Cu EZM113225 EZM113225CU 1861. 2644. EZMR113225 EZMR113225CU 1861. 2644. EZMH113225 EZMH113225CU 2046. 2923. 4 800 A Al 800 A Cu EZM114225 EZM114225CU 2392. 3441. EZMR114225 EZMR114225CU 2392. 3441. EZMH114225 EZMH114225CU 2685. 3881. 1200 A Al/CU EZM115225 1200 A Cu EZM115225CU 3143. 4459. EZMR115225 EZMR115225CU 3143. 4459. EZMH115225 EZMH115225CU 3143. 5198. 17.38 METERING EQUIPMENT 5 225 A Maximum Commercial Branch Units (Order Type QB, QD, QG or QJ Circuit Breakers Separately)i System Type EZML113225 1Ø3W 120/240 Vac 2-Pole Branch Circuit Breakers Number of Meter Sockets Ringless Type 5-Jaw Meter Socket with Lever Bypass and Jaw Releasee Horizontal Cross Bus Rating and Bus Bar Material Catalog Number Width (Dim. see pg. 51) Price Ring Type 5-Jaw Meter Socket with Test Block Bypass. Meets EUSERC Requirements Catalog Number Width (Dim. see pg. 51) Price 1 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu EZML111225 EZML111225CU EZML111225Db 19.44 $1635. 2453. 1717. EZMT111225c ... ... 22.42 ... ... $2258. ... ... 2 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu EZML112225 EZML112225CU EZML112225Db 19.44 2977. 4466. 3126. EZMT112225c ... ... 22.42 ... ... 4095. ... ... 3 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu EZML113225 EZML113225CU EZML113225Db 19.44 4386. 6579. 4605. EZMT113225cg ... ... 22.42 ... ... 6143. ... ... 4 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu EZML114225 EZML114225CU EZML114225Db 19.44 5875. 8813. 6169. ... ... ... ... ... ... ... ... ... 400 A Maximum Commercial Branch Units System Type Number of Meter Sockets Main Cross Bus Rating and Bus Bar Material Ringless Type 5-Jaw Meter Socket with Lever Bypass and Jaw Release— 400 A Type LAL Branch Circuit Breaker Included Factory Installed.deh Catalog Number EZMT111225 1Ø3W 120/240 Vac 2-Pole Branch Circuit Breakers Width (Dim. see pg. 51) Price Ringless Type K Bolt-On 4-Jaw Meter Socket with Manual Bypass— 400A Type DJM Branch Circuit Breaker Included Factory Installed. Ampere rating field adjustable from 160 A–400 A. Catalog Number Width (Dim. see pg. 51) Price 1 1200 A Al/Cu 1200 A Cu EZML111400 EZML111400CU 23.21 $ 3987. 5981. ... EZMK111400 ... 27.56 ... $4949. 2 1200 A Al/Cu 1200 A Cu EZML112400 EZML112400CU 23.21 7975. 11963. ... EZMK112400 ... 27.56 ... 9687. a Snap-on aluminum sealing rings supplied as standard. b Supplied with removable drip hood and equipped with an indoor top endwall with knockouts provided. c Supplied with bondable neutral, suitable for use as service equipment. Use main lugs tapbox type EZM-TBU for 6-Sub Division Rule applications to feed this device. Supplied with copper horizontal bus bars and aluminum vertical bus bars. d Device has limited short circuit current rating, refer to page 53. e Supplied with Class 320 meter socket. f For 1200A main cross bus add suffix “X” to catalog number (Example: EZM314125X). Add $147. per device. Allow 6 weeks for delivery. g Does not meet EUSERC 48" minImum / 75" maximum meter height requirements for outdoor installations. This device measures 37" minimum / 75" maximum. EUSERC indoor requirements are 36" minimum / 75" maximum. h Not UL Listed. i Type QO, QO-VH and QOH branch circuit breakers (40 A–60 A) may be installed with use of EZM125QOA adapter kits, refer to page 50. For additional information, reference Catalog #4100CT9801. 46 DE4 Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering EZ METER-PAK® Meter Centers Three Phase—Indoor/Rainproof www.SquareD.com For the most up-to-date information 3Ø4W EZ METER-PAK Meter Centers— UL Listed Select EZM meter center short circuit current rating RMS symmetrical amperes from table on page 53. Using this table as a reference, make the following selections: ➀ Select three phase EZM main device below with an ➀ Main Devices—NEMA 3R Construction Overhead/Underground Feed System Type Horizontal Bus Ampere Cross Rating andRating Bus Bar Material Catalog Number Price Line Side Lug and Wire Size (AWG–kcmil) Conductor Qty. per Phase and Neutral (Factory Installed) 18.66 18.66 18.66 $ 4413. 6831. 9100. (1) #1–600 or (2) #1–250 (3) 3/0–500 (3) 3/0–500 18.66 30.19 30.19 11351. 15418. 23525. (3) 3/0–500 (4) 1/0–750 (6) 1/0–750 Width (Dim. see pg. 51) equal or higher short circuit rating than the application. ➁ Select EZM three phase branch units from page 48 and 49. ➂ Select proper 2-pole type QO, QO-VH, QOH, QBP-TM, QDP-TM, QGP-TM or QJP-TM or 3-pole QBP-TM, QDP-TM, QGP-TM or QJP-TM branch circuit breakers for use as tenant mains in branch unit; page 50. ➃ Select accessories as required, page 50. ➄ Dimensions, page 51. 65,000 RMS Symmetrical Ampere Short Circuit Current Rating Main Circuit Breakers (3Ø Incoming and 3Ø Outgoing) 3Ø4W 208Y/120 Vac OR 240/120 Vac DELTA 400 600 800 1000 1200 1600 800 A Al 800 A Al 800 A Al EZM3400CBe EZM3600CBe EZM3800CBe 1000 A Al EZM31000CBei 1200 A Al/Cu EZM31200CBfg 1200 A Al/Cu EZM31600CBfg 100,000 RMS Symmetrical Ampere Short Circuit Current Rating Main Fusible Switches (3Ø Incoming and 3Ø Outgoing)— Requires 300 Vac Class T Fuses (Order Separately) 3Ø4W 208Y/120 Vac OR 240/120 Vac DELTA 400 600 800 800 A Al 800 A Al 800 A Al EZM3400FS EZM3600FS EZM3800FS 18.66 18.66 18.66 2977. 5582. 7710. (1) #1–600 or (2 )#1–250 (3) 3/0–500 (3) 3/0–500 3Ø4W 208Y/120 Vac OR 240/120 Vac DELTA 225 225 400 400 800 A Al 800A Cu 800 A Al 800A Cu EZM3225TB EZM3225TBCU EZM3400TB EZM3400TBCU 11.50 11.50 18.66 18.66 675. 749. 742. 1286. (1) 4–300 (1) 4–300 (2) 3/0–500 (2) 3/0–500 600 600 800 800 800 A Al 800A Cu 800 A Al 800A Cu EZM3600TB EZM3600TBCU EZM3800TB EZM3800TBCU 17.00 17.00 23.93 23.93 797. 1415. 961. 2363. (1) 350–750 or (2) 1/0–300 (1) 350–750 or (2) 1/0–300 (4) 3/0–500 (4) 3/0–500 1200 A Al 1200 A Cu EZM31600TBg EZM31600TBCU 22.33 22.33 2685. 3576. (6) 3/0–600 (6) 3/0–600 1600 1600 Underground Feed Only System Type Horizontal Bus Ampere Cross Rating andRating Bus Bar Material Catalog Number Meets EUSERC Requirements Price Factory Installed Lug Landings For Use with Crimp-Type Lugs (2-Hole Mounting) Qty. per Phase and Neutrala 20.46 20.46 20.46 $ 4785. 7204. 9410. 1 (Order Lugs Separately) 2 (Order Lugs Separately) 2 (Order Lugs Separately) 34.19 34.19 30.19 11962. 16215. 24780. 3 (Order Lugs Separately) 3 (Order Lugs Separately) 6 (Order Lugs Separately) Width (Dim. see pg. 51) 65,000 RMS Symmetrical Ampere Short Circuit Current Rating EZM3600FS Main Circuit Breakers (3Ø Incoming and 3Ø Outgoing) 3Ø4W 208Y/120 Vac OR 240/120 Vac DELTA 400 600 800 1000 1200 1600 800 A Al 800 A Al 800 A Al EZM3400CBUe EZM3600CBUe EZM3800CBUe 1000 A Al EZM31000CBUebi 1200 A Al/Cu EZM31200CBUegb 1200 A Al/Cu EZM31600CBUfgd 100,000 RMS Symmetrical Ampere Short Circuit Current Rating Main Circuit Breakers (3Ø Incoming and 3Ø Outgoing) 3Ø4W, 208Y/120 Vac OR 240/120 Vac DELTA 1000 1200 1000 A Al EZM31000CBUei 1200 A Al/Cu EZM31200CBUeg 34.19 34.19 11962. 16215. 3 (Order Lugs Separately) 3 (Order Lugs Separately) 20.46 20.46 20.46 4652. 7576. 10101. 1 (Order Lugs Separately) 2 (Order Lugs Separately) 2 (Order Lugs Separately) Main Fusible Switches (3Ø Incoming and 3Ø Outgoing)— Requires 300 Vac Class T Fuses (Order Separately) 3Ø4W 208Y/120 Vac OR 240/120 Vac DELTA 400 600 800 800 A Al 800 A Al 800 A Al EZM3400FSU EZM3600FSU EZM3800FSU Main Lugs Terminal Boxes (3Ø Incoming and 3Ø Outgoing). Supplied with isolated neutral (can not be bonded).c EZM31600CB For additional information, reference Catalog #4100CT9801. © 2004 Schneider Electric All Rights Reserved 6/7/04 3Ø4W 208Y/120 Vac OR 240/120 Vac DELTA 400 400 800 800 1200 1200 800 A Al 800 A Cu 800 A Al 800 A Cu 1200 A Al/Cu 1200 A Cu EZM3400TBU EZM3400TBUCU EZM3800TBU EZM3800TBUCU EZM31200TBUg EZM31200TBUCU 16.16 16.16 24.16 24.16 32.16 32.16 1225. 1642. 1400. 1875. 2975. 3986. 1 (Order Lugs Separately) 1 (Order Lugs Separately) 2 (Order Lugs Separately) 2 (Order Lugs Separately) 3 (Order Lugs Separately) 3 (Order Lugs Separately) a For mechanical lugs (3/0 to 600 kcmil) order kit catalog number CMELK4, Price $91.00. Kit includes 4 lugs only. Multiple kits may be required, consult factory. For crimp-type lugs refer to Anderson Electrical Connector Products Catalog AEC-40R. b Has a 100,000 RMS symmetrical ampere short circuit current rating. c Has a maximum 100,000 RMS symmetrical short circuit current rating when protected by Class R (600 A Max.) or Class T (800 A Max.) fuses. For other short circuit current ratings refer to table on page 53. Suitable for use on LINE or LOAD side of service equipment. Use to feed type EZMT branch units for 6-Sub Division Rule applications. d Does not meet EUSERC requirements. Not stocked in PDS, order only (allow 6 weeks for delivery). Not UL Listed. e Available by special order with main circuit breaker supplied with other standard ampere ratings, consult your nearest Square D/Schneider Electric sales office (allow 6 weeks for delivery). f Ampere rating of the PA circuit breaker supplied with this main can be changed it field by ordering a different set of rating columns, refer to Digest 173 page 6-25 for listing. g Supplied with copper horizontal bus bars and aluminum vertical bus bars. h May be end mounted to feed branch units with 800 A or 1200 A horizontal cross bus. DE4 Discount Schedule 47 METERING EQUIPMENT Main Lugs Terminal Boxes (3Ø Incoming and 3Ø Outgoing)c Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering EZ METER-PAK® Meter Centers Three Phase—Indoor/Rainproof www.SquareD.com For the most up-to-date information 3Ø4W EZ Meter-Pak Meter Centers — UL Listed ② Branch Devices—NEMA 3R Construction Branch Units—3Ø Incoming and 1Ø Outgoing Width (Dim. see pg. 51) System Type Horizontal Cross Bus Ratingg and Bus Bar Material Number of Meter Sockets Ring Type 5-Jaw Meter Socketa Catalog Number Ringless Type 5-Jaw Meter Socket Catalog Number Price Price Ringless Type 5-Jaw Meter Socket with Horn Bypass Catalog Price Number 125 A Maximum (Order Type QO, QO-VH or QOH Circuit Breakers Separately)agd 800 A Al 800 A Cu 800 A Cu 800 A Al 800 A Cu 800 A Cu 800 A Al 800 A Cu 800 A Cu 800 A Al 800 A Cu 3 3Ø4W 208Y/120 Vac 5-Jaw-Meter Socket 2-Pole Branch Circuit Breakers 4 12.25 5 6 EZML313225 EZM313125 EZM313125M10b EZM313125CU EZM314125 EZM314125M10b EZM314125CU EZM315125 EZM315125M10b EZM315125CU EZM316125 EZM316125CU $1036. 2835. 1408. 1356. 3780. 1887. 1728. 4725. 2445. 1994. 2844. EZMR313125 ... EZMR313125CU EZMR314125 ... EZMR314125CU EZMR315125 ... EZMR315125CU EZMR316125 EZMR316125CU $1036. ... 1408. 1359. ... 1891. 1728. ... 2445. 1994. 2844. EZMH313125 ... EZMH313125CU EZMH314125 ... EZMH314125CU EZMH315125 ... EZMH315125CU EZMH316125 EZMH316125CU $1250. ... 1727. 1649. ... 2326. 2074. ... 2964. 2525. 3641. $1515. 2126. 1861. 2644. 2499. 3602. 3638. 4832. EZMH312225 EZMH312225CU EZMH313225 EZMH313225CU EZMH314225 EZMH314225CU EZMH315225 EZMH315225CU $1649. 2326. 2074. 2964. 2765. 4001. 3812. 5128. 225 A Maximum (Order Type QB, QD, QG or QJ Circuit Breakers Separately)aig 2 3Ø4W 208Y/120 Vac 5-Jaw-Meter Socket 2-Pole Branch Circuit Breakers 3 17.38 4 5 800 A Al 800 A Cu 800 A Al 800 A Cu 800 A Al 800 A Cu 1200 A Al/Cu 1200 A Cu EZM312225 EZM312225CU EZM313225 EZM313225CU EZM314225 EZM314225CU EZM315225 EZM315225CU $1515. 2126. 1861. 2644. 2499. 3602. 3280. 4660. EZMR312225 EZMR312225CU EZMR313225 EZMR313225CU EZMR314225 EZMR314225CU EZMR315225 EZMR315225CU System Type Number of MeterSockets METERING EQUIPMENT 225 A Maximum Commercial Branch Units Horizontal Cross Bus Rating and Bus Bar Material Ringless Type Meter Socket without Bypass Catalog Number Width (Dim. see pg. 51) Ringless Type Meter Socket with Lever Bypass and Jaw Released Catalog Number Price Width (Dim. see pg. 51) Price Ring Type Meter Socket with Test Block Bypass. Meets EUSERC Requirements Width (Dim. Catalog see Price Number pg. 51) 3Ø Incoming and 1Ø Outgoinga (Order Type QB, QD, QG or QJ circuit breakers separately)i 1 EZMT311225 3Ø4W 208Y/120 Vac 5-Jaw Meter Sockets 2-Pole Branch Circuit Breakers 2 3 4 1200 A Al/Cu 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... EZML312225 EZML312225CU EZML312225Dd EZML313225 EZML313225CU EZML313225Dd EZML314225 EZML314225CU EZML314225Dd ... 19.44 19.44 19.44 ... $2844. 4267. 2986. 4280. 6420. 4494. 5821. 8732. 6112. EZMT311225b EZMT312225b ... ... EZMT313225bh ... ... ... ... ... 22.42 22.42 ... ... 22.42 ... ... 1861. 2791. 1954. 3403. 5105. 3573. 5196. 7795. 5456. 7111. 10666. 7476. EZMT331225b ... ... EZMT332225b ... ... EZMT333225bh ... ... ... ... ... 22.42 ... ... 22.42 ... ... 22.42 ... ... ... $2363. 4463. ... ... 6694. ... ... ... ... ... 3Ø Incoming and 3Ø Outgoing (Order QB, QD, QG or QJ circuit breakers separately) 3Ø4W 240/120 Vac DELTA or 208Y/120 Vac 7-Jaw Meter Socket 3-Pole Branch Circuit Breakers EZMT311225 Without Cover 1 2 3 4 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu ... ... ... EZMR332225 EZMR332225CU ... EZMR333225 EZMR333225CU ... EZMR334225 EZMR334225CU ... ... ... ... 19.44 19.44 19.44 ... ... ... $3124. 4686. ... 4891. 7336. ... 6779. 10168. ... EZML331225 EZML331225CU EZML331225Dd EZML332225 EZML332225CU EZML332225Dd EZML333225 EZML333225CU EZML333225Dd EZML334225 EZML334225CU EZML334225Dd 19.44 19.44 19.44 19.44 ... 2625. ... ... 4638. ... ... 6869. ... ... ... ... ... a Snap-On aluminum sealing rings supplied as standard. b Distance between meter sockets as measured from centerline to centerline is 10 inches. c For 240/120 Vac DELTA Systems add Suffix “CA” to catalog number (Example: EZM314125CA). All meter sockets are phased A and C only. Price remains the same as the base catalog number. Order only branch units, not stocked in PDS (6-week delivery). d Supplied with removable drip hood and equipped with an indoor top endwall with knockouts provided. e Supplied with bondable neutral, suitable for use as service equipment. Use main lugs tap box type EZM-TBU for 6-Sub Division Rule applications to feed this device. Supplied with copper horizontal bus bars and aluminum vertical bus bars. f Supplied with Class 320 meter socket. g For 1200 A main cross bus, add suffix “X” to catalog number. Example: EZMR313125X. Add $147. per device. Allow 6 weeks for delivery. h Does not meet EUSERC 48" minimum/75" maximum meter height requirements as measured from grade level to centerline on meter. This device measures 37" minimum/75" maximum i Type QO, QO-VH and QOH branch circuit breakers (40 A–60 A) may be installed with use of EZM125QOA adapter kits, refer to page 50. For 400 A maximum Commercial Branch Units, see page 49. For additional information, reference Catalog #4100CT9801. 48 DE4 Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering EZ METER-PAK® Meter Centers Three Phase—Indoor/Rainproof www.SquareD.com For the most up-to-date information 3Ø4W EZ Meter-Pak Meter Centers — UL Listed ② Branch Devices—NEMA 3R Construction (Continued) 400 A Maximum Commercial Branch Units Number of Meter Sockets System Type Horizontal Cross Bus Rating Ringless Type Meter Socket with Lever Bypass and Jaw Release— 400 A Type LAL Branch Circuit Breaker Included Factory Installed.cd Catalog Number Width (Dim. see pg. 51) Price Ringless Type K Bolt-On Meter Socket with Manual Bypass— 400 A Type DJM Branch Circuit Breaker Included Factory Installed. Ampere rating field adjustable from 160 A–400 A. Width (Dim. Catalog Number Price see pg. 51) 3Ø Incoming and 1Ø Outgoinga 3Ø4W 208Y/120 Vac 5-Jaw Meter Socket 2-Pole Branch Circuit Breakers 1 1200 A Al/Cu 1200 A Cu 23.21 1200 A Cu EZML311400b EZML311400CU EZML312400b EZML312400CU 2 1200 A Al/Cu 1200 A Cu 1200 A Al/Cu 1200 A Cu EZML331400b EZML331400CU EZML332400b EZML332400CU 23.21 23.21 $ 3987. 5981. 7975. 11963. ... EZMK311400 ... EZMK312400 ... 27.56 ... 27.56 ... $ 5949. ... 11689. 4652. 6977. 9304. 13957. ... EZMK331400 ... EZMK332400 ... 27.56 ... 27.56 ... $ 7010. ... 13810. 3Ø Incoming and 3Ø Outgoing 3Ø4W 240/120 Vac DELTA or 208Y/120 Vac 7-Jaw Meter Socket 3-Pole Branch Circuit Breakers EZMK311400 1 2 23.21 EZM Main with Busway Tap EZ METER-PAK metering equipment is available for use in high rise applications for connection to 800 A–5000 A I-LINE® or I-LINE II plug-in busway installed as a vertical riser. Three phase only EZM main devices in the form of a main circuit breaker or main fusible switch are available with an integral busway tap extending from the right or left side of the main device and phased to align with the busway for either neutral front or neutral back installations. BUSWAY Mains, three phase only (Indoor only) ordering instructions: Width Top of EZM Mounting Channel (See Note) EZM Bus Tap 56.11 1425 CL of Busway Plug-in Opening Step #1: Determine height to center line of busway plug-in opening, check local utility requirements for minimum and maximum meter socket heights. Step #2: Determine side of EZM main section for busway tap to extend from (busway tap is an integral part of the main and extends to the left or right on the EZM device as viewed from the front). Step #3: Check phasing of busway riser to insure that it matches phasing of busway tap on main section (indicated as neutral front or neutral back as viewed from the front). 31.11 4.11 790 104 Floor Level EZM3800CBNFBTR Step #4: Select catalog number from tables below. Step #5: Busway main devices are build to order specials and require 4 to 6 weeks for delivery (order point Lexington). EZM Mains with Busway Tap (Three Phase Only—note positioning left or right below) Ampere Width Rating (IN) Width 400 600 800 1000 1200 Neutral Back Main Fusible Switch with Busway Tapf Price Neutral Front Neutral Back Price 18.66 18.66 18.66 18.66 30.19 800 A Al 800 A Al 800 A Al 1000 A Al 1200 A Al/Cu EZM3400CBNFBTR EZM3600CBNFBTR EZM3800CBNFBTR EZM31000CBNFBTRi EZM31200CBNFBTRgh EZM3400CBNBBTR $ 5924. EZM3400FSNFBTR EZM3600CBNBBTR 8342. EZM3600FSNFBTR EZM3800CBNBBTR 10496. EZM3800FSNFBTR EZM31000CBNBBTRi 12861. ... EZM31200CBNBBTRgh 16929. ... EZM3400FSNBBTR EZM3600FSNBBTR EZM3800FSNBBTR ... ... $4488. 7093. 9220. ... ... EZM3400CBNBBTL EZM3600CBNBBTL EZM3800CBNBBTL EZM31000CBNBBTLi EZM31200CBNBBTLgh EZM3400FSNBBTL EZM3600FSNBBTL EZM3800FSNBBTL ... ... $4488. 7093. 9220. ... ... (See Note) Busway to LEFT of metering equipment lineup 56.11 400 600 800 1000 1200 1425 CL of Busway Plug-in Opening 31.11 790 Main Circuit Breaker with Busway Tape Neutral Front Busway to RIGHT of metering equipment lineup Top of EZM Mounting Channel EZM Bus Tap Horizontal Cross Bus Rating 4.11 104 Floor Level EZM3800FSNBBTL e f g h i 18.66 18.66 18.66 18.66 30.19 800 A Al 800 A Al 800 A Al 1000 A Al 1200 A Al/Cu EZM3400CBNFBTL EZM3600CBNFBTL EZM3800CBNFBTL EZM31000CBNFBTLi EZM31200CBNFBTLgh $ 5924. EZM3400FSNFBTL 8342. EZM3600FSNFBTL 10496. EZM3800FSNFBTL 12861. ... 16929. ... Has a maximum 65,000 RMS symmetrical short circuit current rating. Has a 100,000 RMS symmetrical ampere short circuit current rating. Supplied with copper horizontal bus bars and aluminum vertical bus bars. Requires use of branch units supplied with 1200 A horizontal cross bus. May be end mounted to feed branch units with 800 A or 1200 A horizontal cross bus. Note: Dimensions shown will position the centerline of top meter socket of a 125 A, 5-Gang or 6-Gang branch unit at 72" above floor level. Check with utility to meet local requirements. For additional information, reference Catalog #4100CT9801. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE4 Discount Schedule 49 METERING EQUIPMENT a For 240/120 Vac DELTA Systems add Suffix “CA” to catalog number (Example: EZML312400CA). All meter sockets are phased A and C only. Price remains the same as the base catalog number. “Order only” branch units, not stocked in PDS (4–6 week delivery). Order point Lexington. b Supplied with copper horizontal bus bars and aluminum vertical bus bars. c Device has limited short circuit current rating, refer to page 53. d Supplied with Class 320 meter socket. Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering EZ METER-PAK® Meter Centers Tenant Circuit Breakers and Accessories www.SquareD.com For the most up-to-date information ③ Tenant Circuit Breakers Poles 10 kA AIR Ampere Rating 22 kA AIR Cat. No. Price 42 kA AIR Cat. No. Price 100 kA AIR Cat. No. Price Cat. No. Price $ 211.00 211.00 211.00 352.00 434.00 ... ... ... ... ... ... ... ... ... ... 434.00 434.00 926.00 926.00 ... ... ... ... ... ... ... ... 125 A Max. EZM Branch Unit Tenant Circuit Breakers QO2100VH 2-Pole, Plug-on Type Circuit Breaker 2 40 50 60 70 80 QO240 QO250 QO260 QO270 QO280 90 100 110 125 QO290 QO2100 QO2110 QO2125 $ 44.70 44.70 44.70 89.00 126.00 QO240VH QO250VH QO260VH QO270VH QO280VH $ 126.00 126.00 285.00 285.00 QO290VH QO2100VH QO2110VH QO2125VH 97.00 97.00 97.00 149.00 210.00 QOH240 QOH250 QOH260 QOH270 QOH280 210.00 210.00 689.00 689.00 QOH290 QOH2100 QOH2110 QOH2125 97.00 97.00 97.00 762.00 762.00 QOH240b QOH250b QOH260b QGP22070TM QGP22080TM $ 211.00 211.00 211.00 1014.00 1014.00 ... ... ... QJP22070TM QJP22080TM ... ... ... $1260.00 1260.00 225 A Max. EZM Branch Unit Tenant Circuit Breakers 10 kA AIR 2 QDP22200TM 2-Pole, Bolt-on Type Circuit Breaker METERING EQUIPMENT 3 For additional information, reference Catalog #4100CT9801. ④ Accessories 40 50 60 70 80 QO240 QO250 QO260 QBP22070TM QBP22080TM 90 100 125 150 175 25 kA AIR $ $ 100 kA AIR QO240VHa QO250VHa QO260VHa QDP22070TM QDP22080TM QBP22090TM QBP22100TM QBP22125TM QBP22150TM QBP22175TM 316.00 316.00 316.00 316.00 316.00 QDP22090TM QDP22100TM QDP22125TM QDP22150TM QDP22175TM 762.00 762.00 762.00 762.00 762.00 QGP22090TM QGP22100TM QGP22125TM QGP22150TM QGP22175TM 1014.00 1014.00 1014.00 1014.00 1014.00 QJP22090TM QJP22100TM QJP22125TM QJP22150TM QJP22175TM 1260.00 1260.00 1260.00 1260.00 1260.00 200 225 QBP22200TM QBP22225TM 316.00 316.00 QDP22200TM QDP22225TM 762.00 762.00 QGP22200TM QGP22225TM 1014.00 1014.00 QJP22200TM QJP22225TM 1260.00 1260.00 70 80 90 100 125 QBP32070TM QBP32080TM QBP32090TM QBP32100TM QBP32125TM $ 832.00 832.00 832.00 832.00 832.00 QDP32070TM QDP32080TM QDP32090TM QDP32100TM QDP32125TM $1189.00 1189.00 1189.00 1189.00 1189.00 QGP32070TM QGP32080TM QGP32090TM QGP32100TM QGP32125TM $1628.00 1628.00 1628.00 1628.00 1628.00 QJP32070TMc QJP32080TMc QJP32090TMc QJP32100TMc QJP32125TMc $1864.00 1864.00 1864.00 1864.00 1864.00 150 175 200 225 QBP32150TM QBP32175TM QBP32200TM QBP32225TM 832.00 832.00 832.00 832.00 QDP32150TM QDP32175TM QDP32200TM QDP32225TM 1189.00 1189.00 1189.00 1189.00 QGP32150TM QGP32175TM QGP32200TM QGP32225TM 1628.00 1628.00 1628.00 1628.00 QJP32150TMc QJP32175TMc QJP32200TMc QJP32225TMc 1864.00 1864.00 1864.00 1864.00 a QO-VH tenant circuit breaker is rated 22 kA AIR max. b QOH tenant circuit breaker is rated 42 kA AIR max. c 3-pole QJP tenant circuit breaker is rated 65 kA AIR max. at 240/120 Vac, 3-Phase, 4-Wire High Leg DELTA, or 100kA AIR max. at 208Y/120 Vac, 3-Phase, 4-Wire. Description FIFTH JAW KIT (1 per kit) Secondary Surge Arrester Mounting Kit For use with 1 or 2-SDSA1175 or 1-SDSA3650 (order surge arrester separately) Transition Section, 1200 A (10.7" wide) Add right of old style 1Ø EZM lineup Add right of old style 3Ø EZM lineup Add left of old style 1Ø EZM lineup Add left of old style 3Ø EZM lineup 1200 A 1Ø3W BUSSED EXTENSION (Indoor/Outdoor) 1200 A 1Ø3W BUSSED CORNER for INSIDE CORNER (NEMA 1 indoor only) 1200 A 3Ø4W BUSSED EXTENSION (Indoor/Outdoor) 1200 A 3Ø4W BUSSED CORNER for INSIDE CORNER (NEMA 1 indoor only) 1200 A, 1-Phase, 3-Wire BUSSED ELBOW for OUTSIDE CORNER (NEMA 1 indoor only) 1200 A, 3-Phase, 4-Wire BUSSED ELBOW for OUTSIDE CORNER (NEMA 1 indoor only) Stud Kit for 400 A TAP BOX includes (2) 1/2"-13 studs per pad and mounting hardware. Four pads per kit. Stud Kit for 800 A TAP BOX includes (4) 1/2"-13 studs per pad and mounting hardware. Four pads per kit. LEXAN METER SOCKET CLOSING PLATE Not for use on commercial sockets. Q2 CIRCUIT BREAKER CLOSING PLATE MOUNTING CHANNEL (72" long) METAL CLOSING PLATE For use only on Type EZML and EZMR (3Ø IN-3Ø OUT) branch units. SEALING RINGS: SNAP-ON (Stainless Steel) SCREW-Type (Aluminum) LATCH-Type (Aluminum)-standard HORN BYPASS KIT (use with type EZMR 1Ø meter socket only) BARREL LOCK KIT For use on ringless EZM or MP branch unit covers, includes 6 each of head protectors, lock nuts and sealing caps. (Barrel lock not included.) QO ADAPTER for BOLT-ON Q-frame Tenant Circuit Breakers (40–60 A, 2-Pole) EQUIPMENT GROUND TERMINAL ④ Accessories (Continued) Catalog Number 5Jd MMSAMKe Price $ 12.20 53.00 EZM1TRANR EZM3TRANR EZM1TRANL EZM3TRANL 158.00 168.00 210.00 221.00 EZM1EXT 511.00 EZM1CORNER EZM3EXT 1192.00 644.00 EZM3CORNER 1478.00 EZM1ELBOW 1192.00 EZM3ELBOW 1478.00 EZMSK2 164.00 EZMSK4 328.00 Description SLIDER TYPE MANUAL CIRCUIT CLOSER (for one Ring Type socket only): 125–200 A (Indoor/Outdoor) ANTI-INVERSION CLIP Rejects use of 100 A and 200 A meters in Class 320 meter sockets in Type EZML branch units. Al/Cu Lug Kits (Each kit includes three, 2-barrel lugs.) (1) #1/0–600 kcmil or (2) #1/0–250 kcmil per lug (2) #3/0–500 kcmil per lug (2) #2–600 kcmil per lug Catalog Number Price MM200MBfg 114.00 59676 MMLK250 MMLK500 MMLK600 EZM busway transition section provides no overcurrent protection for the downstream EZM branch units. Tenant main circuit breakers in these branch units must be selected as “fully rated” equipment. (Examples: QO for 10 kA, QO-VH for 22 kA or QOH for 42 kA.) 7.40 42.00 RSG4 81.00 16.11 409 Width 409 Width 4.11 6.70 EZMPCP EZM72MC 4.11 104 104 EZM Bus Tap Top of EZM Mounting Channel 11.10 13.40 5.00 MMHB 11.10 MMBLC 44.10 EZM Bus Tap 1.00 1.00 55.11 55.11 25 Top of EZM Mounting Channel 25 CL of Busway Plug-in Opening CL of Busway Plug-in Opening 56.11 ARP00026 29008W 2920910001 100.00 133.00 155.00 Busway Transition Section 16.11 29007 5.30 d All sockets include 5th Jaw Factory installed except EZM11__ devices. e Consult your nearest Square D/Schneider Electric sales office for details. f Meter center short circuit current rating is 10,000 RMS symmetrical amperes with manual circuit closers installed (bypass is not designed for use as continuous duty). g For use on ring type meter sockets only. 1425 1400 56.11 1400 Floor Level 1425 Floor Level EZM3BUSRF and EZM3BUSRB EZM3BUSLF and EZM3BUSLB EZM Busway Transition Sections (three phase only) Ampere Rating Neutral Front Neutral Back Width (IN) Price I-LINE® Busway located on RIGHT side of EZM Transition Section EZM125QOA .... 182.00 Included 1200 DE2A EZM3BUSRF EZM3BUSRB 12.00 $2625. I-LINE Busway located on LEFT side of EZM Transition Section 1200 50 65 kA AIR 44.70 44.70 44.70 316.00 316.00 Discount Schedule EZM3BUSLF EZM3BUSLB 12.00 2625. © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering EZ METER-PAK® Meter Centers Dimensions www.SquareD.com For the most up-to-date information Main Devices Branch Devices Depth (D) 53.97 70.05 61.19 70.05 61.19 70.05 51.58 44.71 61.19 71.19 51.58 21.81 53.97 69.03 53.97 69.03 28.43 35.71 53.97 69.03 53.97 69.03 28.43 53.97 69.03 53.97 69.03 51.76 39.96 19.34 18.66 34.19 30.19 34.19 30.19 34.19 22.33 33.16 30.19 30.19 22.33 11.50 18.66 20.46 18.66 20.46 17.00 17.16 18.66 20.46 18.66 20.46 17.00 18.66 20.46 18.66 20.46 23.93 25.06 11.66 11.50 18.33 18.33 18.33 18.33 18.33 13.00 11.12 18.33 18.33 13.00 5.81 11.50 11.50 11.50 11.50 6.53 8.00 11.50 11.50 11.50 11.50 6.53 11.50 11.50 11.50 11.50 6.41 11.12 6.37 19.50 14.40 8.02 11.85c 19.50 14.52 8.01 11.85c 53.97 70.05 61.19 70.05 51.58 44.71 61.19 71.19 51.58 21.81 53.97 69.03 53.97 69.03 28.43 35.71 53.97 69.03 53.97 69.03 28.43 53.97 69.03 53.97 69.03 51.76 39.96 19.34 18.66 34.19 30.19 34.19 22.33 33.16 30.19 30.19 22.33 11.50 18.66 20.46 18.66 20.46 17.00 17.16 18.66 26.19 18.66 26.19 17.00 18.66 26.19 18.66 26.19 23.93 25.06 11.66 11.50 18.33 18.33 18.33 13.00 11.12 18.33 18.33 13.00 5.81 11.50 11.50 11.50 11.50 6.53 8.00 11.50 11.65 11.50 11.65 6.53 11.50 11.65 11.50 11.65 6.41 11.12 6.37 34.30 46.99 38.13 46.99 27.92 31.17 38.13 48.12 27.92 13.00c 34.30 49.37 34.30 49.37 16.29 27.17 34.30 49.37 34.30 49.37 16.29 34.30 49.37 34.30 49.37 28.01 31.17 11.85c 19.50 14.40 8.02 11.85c 19.500 14.52 8.01 11.85c Height (H) Catalog Number EZM11000CB EZM11000CBU EZM11200CB EZM11200CBU EZM11200FS EZM11200FSU EZM11200TB [CU] EZM11200TBU [CU] EZM11600CB EZM11600CBU EZM11600TB [CU] EZM1225TB [CU] EZM1400CB EZM1400CBU EZM1400FS EZM1400FSU EZM1400TB [CU] EZM1400TBU [CU] EZM1600CB EZM1600CBU EZM1600FS EZM1600FSU EZM1600TB [CU] EZM1800CB EZM1800CBU EZM1800FS EZM1800FSU EZM1800TB [CU] EZM1800TBU [CU] EZM1EXT EZM1CORNER (indoor only)a EZM1ELBOW (indoor only)b EZM31000CB EZM31000CBU EZM31200CB EZM31200CBU EZM31200TB [CU] EZM31200TBU [CU] EZM31600CB EZM31600CBU EZM31600TB [CU] EZM3225TB [CU] EZM3400CB EZM3400CBU EZM3400FS EZM3400FSU EZM3400TB [CU] EZM3400TBU [CU] EZM3600CB EZM3600CBU EZM3600FS EZM3600FSU EZM3600TB [CU] EZM3800CB EZM3800CBU EZM3800FS EZM3800FSU EZM3800TB [CU] EZM3800TBU [CU] EZM3EXT EZM3CORNER (indoor only)a EZM3ELBOW (indoor only)b a Each leg of this corner section measures 14.72" from wall to start of next enclosure. b Each leg of elbow section measures 6.17" corner of wall to start of next enclosure. c Device supplied without mounting channel, secure to wall by use of swingable mounting feet. d Standard branch units are available without suffix added. W W H MC (Mounting Channel) MC (Mounting Channel) T H B Branch Device For additional information, reference Catalog #4100CT9801. © 2004 Schneider Electric All Rights Reserved 6/7/04 Main Device Catalog Number [available suffix] Height (H) Width (W) Depth (D) Mtg. Channel (MC) Top Meter (T) Bottom Meter (B) 43.41 42.37 43.41 48.12 52.00 57.12 61.00 66.12 43.41 42.37 43.41 48.12 52.00 57.12 61.00 66.12 45.55 72.99 39.06 39.06 44.55 39.06 39.06 69.61 53.06 53.06 67.06 67.06 43.41 42.37 43.41 48.12 52.00 57.12 61.00 66.12 25.45 60.56 79.56 17.38 12.25 17.38 12.25 17.38 12.25 17.38 12.25 17.38 12.25 17.38 12.25 17.38 12.25 17.38 12.25 27.56 27.56 19.44 19.44 23.21 19.44 19.44 23.21 19.44 19.44 19.44 19.44 17.38 12.25 17.38 12.25 17.38 12.25 17.38 12.25 22.42 22.42 22.42 8.09 7.09 8.09 7.09 8.09 7.09 8.09 7.09 8.09 7.09 8.09 7.09 8.09 7.09 8.09 7.09 9.74 9.74 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 8.09 7.09 8.09 7.09 8.09 7.09 8.09 7.09 9.38 9.38 9.38 32.34 31.30 32.34 31.30 32.34 31.30 40.03 40.30 32.34 31.30 32.34 31.30 32.34 31.30 40.03 40.30 37.81 37.81 25.51 25.51 37.81 25.51 25.51 37.81 39.51 39.51 39.51 39.51 32.34 31.30 32.34 31.30 32.34 31.30 40.03 40.30 16.19 43.63 48.25 22.18 13.18 13.18 9.93 12.77 9.93 12.77 9.93 22.18 13.18 13.18 9.93 12.77 9.93 12.77 9.93 24.51 22.26 25.67 25.67 24.02 11.67 11.67 20.64 11.67 11.67 11.67 11.67 22.18 13.18 13.18 9.93 12.77 9.93 12.77 9.93 4.67 12.67 12.67 12.23 11.19 12.23 11.19 12.23 11.19 12.23 11.19 12.23 11.19 12.23 11.19 12.23 11.19 12.23 11.19 21.04 21.04 13.39 13.39 21.53 13.39 13.39 21.53 13.39 13.39 13.39 13.39 12.23 11.19 12.23 11.19 12.23 11.19 12.23 11.19 20.45 28.89 28.89 43.41 42.37 42.37 43.41 48.12 52.12 52.00 57.12 62.12 61.00 66.12 43.41 42.37 43.41 48.12 52.00 57.12 61.00 66.12 45.55 72.99 45.55 72.99 45.55 39.06 39.06 39.06 69.61 53.06 53.06 67.06 67.06 39.06 39.06 45.55 39.06 39.06 69.61 53.06 53.06 67.06 67.06 43.41 42.37 43.41 48.12 52.00 57.12 61.00 66.12 39.06 53.06 67.06 25.45 60.56 79.56 25.12 60.56 79.56 17.38 12.25 12.25 17.38 12.25 12.25 17.38 12.25 12.25 17.38 12.25 17.38 12.25 17.38 12.25 17.38 12.25 17.38 12.25 27.56 27.56 27.56 27.56 23.21 19.44 19.44 19.44 23.21 19.44 19.44 19.44 19.44 19.44 19.44 23.21 19.44 19.44 23.21 19.44 19.44 19.44 19.44 17.38 12.25 17.38 12.25 17.38 12.25 17.38 12.25 19.44 19.44 19.44 22.42 22.42 22.42 22.42 22.42 22.42 8.09 7.09 7.09 8.09 7.09 7.09 8.09 7.09 7.09 8.09 7.09 8.09 7.09 8.09 7.09 8.09 7.09 8.09 7.09 9.74 9.74 9.74 9.74 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 9.44 8.09 8.09 8.09 7.09 8.09 7.09 8.09 7.09 9.44 9.44 9.44 9.38 9.38 9.38 9.38 9.38 9.38 32.34 31.30 24.29 32.34 31.30 34.29 32.34 31.30 34.29 40.03 40.30 32.34 31.30 32.34 31.30 32.34 31.30 40.03 40.30 30.60 37.81 30.60 37.81 37.81 25.51 25.51 25.51 37.82 39.51 39.51 39.51 39.51 25.51 25.51 37.81 35.51 35.51 37.82 39.51 39.51 39.51 39.51 32.34 31.30 32.34 31.30 32.34 31.30 40.03 40.30 25.51 39.51 39.51 16.19 43.63 48.25 16.19 43.63 48.25 22.18 13.18 10.18 13.18 9.93 9.93 12.77 9.93 9.93 12.77 9.93 22.18 13.18 13.18 9.93 12.77 9.93 12.77 9.93 24.51 22.26 24.51 22.26 24.02 25.67 11.67 11.67 20.64 11.67 11.67 11.67 11.67 25.67 25.67 24.02 11.67 11.67 20.64 11.67 11.67 11.67 11.67 22.18 13.18 13.18 9.93 12.77 9.93 12.77 9.93 11.67 11.67 11.67 4.67 12.67 12.67 4.67 12.67 12.67 12.23 11.19 12.19 12.23 11.19 12.19 12.23 11.19 12.19 12.23 11.19 12.23 11.19 12.23 11.19 12.23 11.19 12.23 11.19 21.04 21.04 21.04 21.04 21.53 13.39 13.39 13.39 21.53 13.39 13.39 13.39 13.39 13.39 13.39 21.53 13.39 13.39 21.53 13.39 13.39 13.39 13.39 12.23 11.19 12.23 11.19 12.23 11.19 12.23 11.19 13.39 13.39 13.39 20.45 28.89 28.89 20.45 28.89 28.89 Single Phased EZM112225 [X, CU, CUX] EZM113125 [X, CU, CUX] EZM113225 [X, CU, CUX] EZM114125 [X, CU, CUX] EZM114225 [X, CU, CUX] EZM115125 [X, CU, CUX] EZM115225 [X, CU, CUX] EZM116125 [X, CU, CUX] EZMH112225 [X, CU, CUX] EZMH113125 [X, CU, CUX] EZMH113225 [X, CU, CUX] EZMH114125 [X, CU, CUX] EZMH114225 [X, CU, CUX] EZMH115125 [X, CU, CUX] EZMH115225 [X, CU, CUX] EZMH116125 [X, CU, CUX] EZMK111400 EZMK112400 EZML111225 [CU] EZML111225D EZML111400 [CU] EZML112225 [CU] EZML112225D EZML112400 [CU] EZML113225 [CU] EZML113225D EZML114225 [CU] EZML114225D EZMR112225 [X, CU, CUX] EZMR113125 [X, CU, CUX] EZMR113225 [X, CU, CUX] EZMR114125 [X, CU, CUX] EZMR114225 [X, CU, CUX] EZMR115125 [X, CU, CUX] EZMR115225 [X, CU, CUX] EZMR116125 [X, CU, CUX] EZMT111225 EZMT112225 EZMT113225 Three Phased EZM312225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZM313125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZM313125M10 EZM313225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZM314125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZM314125M10 EZM314225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZM315125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZM315125M10 EZM315225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZM316125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMH312225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMH313125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMH313225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMH314125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMH314225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMH315125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMH315225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMH316125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMK311400 [CA] EZMK312400 [CA] EZMK331400 [CA] EZMK332400 [CA] EZML311400 [CU, CA, CUCA] EZML311225 [CU, CA, CUCA] EZML312225 [CU, CA, CUCA] EZML312225D [CA] EZML312400 [CU, CA, CUCA] EZML313225 [CU, CA, CUCA] EZML313225D [CA] EZML314225 [CU, CA, CUCA] EZML314225D [CA] EZML331225 [CU] EZML331225D EZML331400 [CU] EZML332225 [CU] EZML332225D EZML332400 [CU] EZML333225 [CU] EZML333225D EZML334225 [CU] EZML334225D EZMR312225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMR313125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMR313225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMR314125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMR314225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMR315125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMR315225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMR316125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] EZMR332225 [CU] EZMR333225 [CU] EZMR334225 [CU] EZMT311225 [CA] EZMT312225 [CA] EZMT313225 [CA] EZMT331225 EZMT332225 EZMT333225 51 METERING EQUIPMENT Width (W) Mtg. Channel (MC) 34.30 46.99 38.13 46.99 38.13 46.99 27.92 31.17 38.13 48.12 27.92 13.00c 34.30 49.37 34.30 49.37 16.29 27.17 34.30 49.37 34.30 49.37 16.29 34.30 49.37 34.30 49.37 28.01 31.17 11.85c Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering EZ METER-PAK® Meter Centers Indoor/Rainproof www.SquareD.com For the most up-to-date information 240 Vac Maximum, NEMA 3R Construction Meter Centers for use on AC-Systems. Suitable for use as Service Equipment. Utility Company Requirements: Review local utility requirements to Main Devices: METERING EQUIPMENT ensure that metering equipment meets their standards. EZ METER-PAK meter center enclosures meet NEC wire bending requirements, and are designed for wall mounting only (not suitable for floor mounting). All unmetered conductor compartments are sealable by the utility company. EZ METER-PAK meter centers have UL Listed short circuit current ratings up to 100,000 RMS symmetrical amperes at 240 Vac when properly applied. Refer to table below for details and appropriate downstream load centers and panelboards. Suitable incoming services for an EZM main device and available outgoing feeder(s) to downstream panelboards from EZM branch section(s): Incoming Service to Main Device 120/240 Vac, 1Ø3W: Available outgoing feeder(s) to downstream panelboards: • 120/240 Vac, 1Ø3W (4-jaw ring type meter sockets, 2-pole circuit breakers) (5-jaw ringless meter sockets, 2-pole circuit breakers) Incoming Service to Main Device 240/120 Vac, 3Ø4W Delta: Available outgoing feeder(s) to downstream panelboards: • 120/240 Vac, 1Ø3W (Fed from transformer’s “A-Phase” and “C-Phase” only.) NOTE: Connection to High-Leg “B-Phase” not permitted for this service (4-jaw ring type meter sockets, 2-pole circuit breakers) (5-jaw ringless meter sockets, 2-pole circuit breakers) Standard 3-Phase IN/1-Phase OUT branch units are not suitable for use on this DELTA System. Special branch units are available for this System by adding suffix: “CA” to catalog number (Typical Examples: EZM313125CA, EZMH314200CA, etc.). • 240/120 Vac, 3Ø4W Delta (7-jaw meter sockets, 3-pole circuit breakers) Incoming Service to Main Device 208Y/120 Vac, 3Ø4W: Available outgoing feeder(s) to downstream panelboards: • 120/208 Vac, 1Ø3W (5-jaw meter sockets, 2-pole circuit breakers) • 208Y/120 Vac, 3Ø4W (7-jaw meter sockets, 3-pole circuit breakers) • 1200 A main disconnect or terminal box must be center mounted when used with branch devices with main bus rated 800 A. • 1600 A main disconnect or terminal box must be center mounted. • 400, 800 and 1200 A type EZM-TBU tap boxes supplied with lug landings to meet EUSERC requirements. Main Circuit Breaker, ratings: 400, 600, 800, 1000, 1200, and 1600 A Main Fusible Switch, ratings: 400, 600, 800, and 1200 A (1 phase, 3 wire only) Main Lugs Terminal Box, ratings: 225 A, 400, 600, 800, 1200, and 1600 A Branch Unit: • 125 A and 225 A residential branch units, available in ring or ringless type construction and supplied with 800 A horizontal cross bus. For all-copper bussing, add suffix “CU” to catalog number (Example: EZM314125CU). Plug-in style meter sockets are available as ring type EZM without bypass, ringless type EZMR without bypass, and ringless type EZMH with horn bypass. For 1200 A main cross bus, add suffix “X” to catalog number (Example: EZM314125X). • 225 A commercial branch units, available in ring or ringless type construction and supplied with 1200 A horizontal cross bus. For all-copper bussing, add suffix “CU” to catalog number (Example: EZML334200CU). Plug-in style meter sockets are available as ringless type EZMR without bypass, ringless type EZML with lever bypass and ring type EZMT with test block bypass (meets EUSERC requirements). • 400 A branch units, Type EZML branch units are available in ringless type construction, supplied with 1200 A AL/CU (standard), or 1200 A copper (add suffix “CU” ) horizontal cross bus. This plug-in meter socket is supplied with lever bypass and jaw release. Type EZMK branch units are supplied with 1200 A copper (standard) horizontal cross bus. This bolt-on meter socket is supplied with a manual bypass. • Units having 800 A horizontal cross bus WILL CONNECT with units having 1200 A horizontal cross bus. • Single Phase units (three bus bars in horizontal cross bus) WILL NOT CONNECT with three phase units (four bus bars in horizontal cross bus). Square D Certified Ratings for Downstream Panelboards:a For load centers or panelboards installed downstream from any UL Listed MP METER-PAK (single phase only) or EZ METER-PAK meter center applied on a system capable of delivering greater than 10,000 RMS symmetrical amperes. Requires a minimum of 20 feet of cable between meter center and downstream load center or panelboard. all ratings verified by actual Square D tests. QO Load Centers or NQOD Panelboards with Branch Circuit Breakers rated 10,000 AIR HOM Load Centers with Branch Circuit Breakers rated 10,000 AIR Downstream Single Phase Load Center or Panelboard QO, QOB – 1-Pole (15 A–70 A) QOT–1-Pole (15 A–70 A) QO-GFI, QOB-GFI–1-Pole (15 A–30 A) QO-AFI, QOB-AFI–1-Pole (15 A–20A) QO, QOB–2-Pole (15 A–125 A) HOM–1-Pole (15 A–50 A) HOMT–1-Pole (15 A–20 A) HOM-AFI–1-Pole (15A–20A) HOM-GFI–1-Pole (15 A–20 A) HOM–2-Pole (15 A–70 A) HOMT–2-Pole (15 A–30 A) Downstream Three Phase Load Center or Panelboard QO, QOB– 1-Pole (15 A–70 A) 2-Pole (15 A–125 A) 3-Pole (15 A–100 A) QO-AFI, QOB-AFI–1-Pole (15 A–20 A) QO-GFI, QOB-GFI–1-Pole (15 A–30 A) Meter Center 125 A and 225 A Branch Units ... a For additional information, refer to Data Bulleting #4100DB0301. For additional information, reference Catalog #4100CT9801. 52 © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Metering EZ METER-PAK® Meter Centers Short Circuit Current Ratings www.SquareD.com For the most up-to-date information • Review local utility requirements to ensure that metering equipment meets their standards. • Check local utility to determine available fault current at the meter center. • Using the SCCR table: — Select meter center configuration, main lugs only (6-Subdivision Rule), or remote main, main circuit breaker, or main fusible switch. — Read down to select SCCR equal to, or greater than desired rating. — Read across to select branch unit tenant circuit breaker type. — Continue reading across to select EZM main device type. • With information obtained from table below, turn to appropriate selection/ pricing pages to determine catalog numbers for main device, branch units, and tenant circuit breakers to complete meter center. UL Listed Meter Center Short Circuit Current Ratings (SCCR) EZM Meter Center Overcurrent Protection Devices Short Circuit Current Rating EZM Branch Unit Tenant Circuit Breaker EZM Main Device (RMS Symmetrical Types Available with Integral Mounted Main, Amperes at (Branch Unit Amperes max., Number of Remote Mounted Main or 240 Vac Poles, Tenant Circuit Breaker Amperes without an Upstream Mounted Main Maximum)ab Rating Range) (6-Sub-Division Rule) EZ METER-PAK (6-Subdivision Rule Applications)—See Figure 1 10,000 18,000 22,000 25,000 42,000 65,000 100,000 10,000 QO (125 A, 2-Pole, 40–125 A) QO (225 A, 2-Pole, 40–125 A)e QB (225 A 2 or 3-Pole, 70–225 A) 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream Disconnecting Means Rated 10,000 AIR minimum 18,000 LAL (400 A, 2 or 3-Pole, 125–400 A)e 22,000 QO-VH (125 A, 2-Pole, 40–125 A) QO-VH (225 A, 2-Pole, 40–60 A)e 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream Disconnecting Means Rated 18,000 AIR minimum 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream Disconnecting Means Rated 22,000 AIR minimum 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream Disconnecting Means Rated 25,000 AIR minimum 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream Disconnecting Means Rated 42,000 AIR minimum 25,000 QD (225 A 2 or 3-Pole, 70–225 A) 42,000 QOH (125 A, 2-Pole, 40–125 A) QOH (225 A, 2-Pole, 40–60 A)e QO-VH (125 A, 2-Pole, 40–125 A) QO-VH (225 A, 2-Pole, 40–60 A)e QD (225 A 2 or 3-Pole, 70–225 A) DJM (400 A, 2 or 3-Pole,160–400 A)f 65,000 Load Centers (Main Lugs) 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream Disconnecting Means Rated 65,000 AIR minimum QO-VH (125 A, 2-Pole, 40–125 A) QO-VH (225 A, 2-Pole, 40–60 A)e QD (225 A 2 or 3-Pole, 70–225 A) DJM (400 A, 2 or 3-Pole, 160–400 A)f 225–1600 A Main Lugs Terminal Box Must be protected by a Square D Circuit Breaker Type LH (400 A max.), MH (1000 A max.) or PA (1600 A max.) Rated 65,000 AIR minimum QJ (225 A 2-Pole only, 70–225 A ) QJ (225 A 3-Pole only, 70–225 A) QO-VH (125 A, 2-Pole, 40–125 A) QO-VH (225 A, 2-Pole, 40–60 A)e DJM (400 A, 2 or 3-Pole, 160–225 A)f QD (225 A 2-Pole only, 70–225 A) QD (225 A 3-Pole only, 70–225 A)c Service Disconnects (6 Max.) 225–1600 A Main Lugs Terminal Box Must be protected by a Square D Circuit Breaker Type LA (400 A max.) or MA (800 A max.) Rated 42,000 AIR minimum QG (225 A 2 or 3-Pole, 70–225 A) QD (225 A 2 or 3-Pole, 70–225 A) 100,000 Transformer 225–1600 A Main Lugs Terminal Box (Tenant Circuit Breakers used as Service Disconnects—6 maximum) EZ METER-PAK—Main Lugs Terminal Box Applications Protected By Remote Main—See Figure 2 • Refer to “Square D Certified Ratings” table on page 52 to determine suitable downstream load centers or panelboards. EZM Branch Units QO (125 A, 2-Pole, 40–125 A) QO (225 A, 2-Pole, 40–125 A)e QB (225 A, 2 or 3-Pole, 70–225 A) LAL (400 A, 2 or 3-Pole, 125–400 A)e QO-VH (125 A, 2-Pole, 40–125 A ) QO-VH (225 A, 2-Pole, 40–60 A)e QD (225 A, 2 or 3-Pole, 70–225 A) QOH (125 A, 2-Pole, 40–125 A) QOH (225 A, 2-Pole, 40–60 A)e QG (225 A, 2 or 3-Pole, 70–225 A) QJ (225 A, 2-Pole only, 70–225 A) QJ (225 A, 3-Pole only, 70–225 A) c DJM (400 A, 2 or 3-Pole, 160–400 A)f 225–1600 A Main Lugs Terminal Box Must be protected by a Square D Circuit Breaker Type MG (800 A max.), PG (1200 A max.) or RG (1600 A max.) Rated 65,000 AIR minimum 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream Disconnecting Means Rated 100,000 AIR minimum Must be protected by an Upstream Disconnection Means with Class R (600 A max.), or Class T (300 Vac, 800 A maximum) fuses. Must be protected by an Upstream Disconnection Means with Class J (600 A max.), Class L (1200 A max.), Class R (600 A max.), Class T (300 Vac, 1200 A max.) or Class T (600 Vac, 800 A maximum) fuses. Or be protected by a Square D circuit breaker Type MJ (800 A max.), PJ (1200 A max.), PH (1600 A max.) or RJ (1600 A max.) Rated 100,000 AIR minimum. EZ METER-PAK—Main Circuit Breaker Applications—See Figure 3 EZM Main Lugs Terminal Box 10,000 Figure 1 18,000 EZM Main Lugs Terminal Box EZM Branch Units 65,000 100,000 Transformer Tenant Circuit Breakers Load Centers (Main Lugs) Upstream Disconnection Means and Overcurrent Protection as required Figure 2 10,000 42,000 EZM Branch Units 65,000 100,000 100,000 Transformer Tenant Circuit Breakers Figure 3 Load Centers (Main Lugs) 400–1600 A EZM Main Device with Type LH (400 A max.), MH (1000 A max.) or PA (1600 A max.) Circuit Breaker. 1000–1200 A Main Device with Catalog Number Suffix "CBU" supplied with Type MHF Circuit Breaker. EZ METER-PAK—Main Fusible Switch Applications—See Figure 3 18,000 EZM Circuit Breaker Main or EZM Main Fusible Switch QO (125 A, 2-Pole, 40–125 A) QO (225 A, 2-Pole, 40–125 A)e QB (225 A 2 or 3-Pole, 70–225 A) LAL (400 A, 2 or 3-Pole, 120–400 A)e QO-VH (125 A, 2-Pole, 40–125 A) QO-VH (225 A, 2-Pole, 40–60 A)e QD (225 A 2 or 3-Pole, 70–225 A) DJM (400 A, 2 or 3-Pole, 160–400 A) QO-VH (125 A, 2-Pole, 40–125 A) QO-VH (225 A, 2-Pole, 40–60 A)e QD (225 A 2-Pole only, 70–225 A) QD (225 A 3-Pole only, 70–225 A)c DJM (400 A, 2 or 3-Pole, 160–400 A)f QO (125 A, 2-Pole, 40–125 A) QO (225 A, 2-Pole, 40–125 A)e QB (225 A 2 or 3-Pole, 70–225 A) LAL 400 A, 2 or 3-Pole, 125–400 A)e QO-VH (125 A, 2-Pole, 40–125 A) QO-VH (225 A, 2-Pole, 40–60 A)e DJM (400 A, 2-Pole, 160–400 A)f QD (225 A 2-Pole, 70–225 A) QO-VH (125 A, 2-Pole, 40–125 A) QO-VH (225 A, 2-Pole, 40–60 A)e QD (225 A 2-Pole only, 70–225 A) QD (225 A 3-Pole only, 70–225 A)c DJM (400 A, 2 or 3-Pole, 160–400 A)f 400–800 A EZM Main Device (1-Phase or 3-Phase) with Class T (300 Vac) Fuses installed. 1200 A EZM Main Device (1-Phase only) with Class T (300 Vac) Fuses installed. 400–800 A EZM Main Device (1-Phase or 3-Phase) with Class T (300 Vac) Fuses installed. a Meter center short circuit current rating is equal to the lowest short circuit current rating given in the table for any circuit breaker installed in any meter panelboard in the meter center. b Short circuit current rating is measured at the LINE SIDE terminals of the integral mounted or remote mounted main providing overcurrent protection for the EZM metering equipment lineup. c Limited to 208Y/120 Vac maximum (3-pole circuit breaker only). d Requires use of EZM125QOA adapter (order separately). Refer to page 50 for pricing. e Supplied with 400 A circuit breaker(s) factory installed, consult local field office for ordering other ampere ratings. f Supplied with factory installed circuit breaker(s), with an adjustable trip rating range of 160–400 A. For additional information, reference Catalog #4100CT9801. © 2004 Schneider Electric All Rights Reserved 6/7/04 53 METERING EQUIPMENT Selection Information Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Switches & D I S C O N N E C T S Safety Switches In 1909 Thomas Edison chose a Square D safety switch for his laboratories in Philadelphia. Today, Square D safety switches are still the best choice for performance and reliability. That’s why professionals choose Square D safety switches 2:1 over any other brand. General Duty Switches Square D general duty safety switches meet the needs of residential and commercial applications with many features designed for economy, safety, and superior performance. They are ideal for lighting, air conditioning, and appliance loads up to 240 Vac. In addition, they may be used as service entrance equipment. ■ Simplifies installation, operation, and maintenance while saving money. ■ Rugged enclosures built to last. ■ Padlock provisions. ■ Operating mechanism exceeds the number of operations required by NEMA and UL standards. 54 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz General Duty Safety Switches Light Duty Class 3130 www.SquareD.com For the most up-to-date information General Duty— Up To 100,000 A Short Circuit Current Rating With Proper Current Limiting Fusing General duty safety switches are designed for residential and commercial applications where economy is a prime consideration. Typical loads are lighting, air conditioning and appliances. They are suitable for use as service equipment when equipped with a factory-installed neutral assembly or a field-installed service grounding kit. General duty safety switches are UL Listed, File E2875, and meet or exceed the NEMA Standard KS1. 400 and 600 A general duty switches (NEMA 1 only) will accept Class J fuses and are UL Listed for use on systems with up to 100,000 RMS symmetrical amperes available fault current. 600 A requires Class J fuse kit—GDJK600 (page 56). Class T 400–800 A general duty safety switches, use 300 Vac Class T fuses and are UL Listed for use on systems with up to 100,000 RMS symmetrical amperes available fault current. Fusible System Amps Fuse Catalog Number Price NEMA 3Ra Rainproof Catalog Number Class R Fuse Kits Field Installableb Price Catalog Number Price Horsepower Ratings Std. Max. (Using Fast Acting- (Using Dual ElementOne Time Fuses) Time Delay Fuses) 1Ø 3Ø 1Ø 3Ø 2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac 30 Plug Use Light Duty Device for This Application (see below) – – – – 30 Cart. Use 3 Wire Devices for this application. – – – – 11⁄2 11⁄2 3 71⁄2 15 – – – 3 c 71⁄2 c 15 c 25 c – – 3 3 10 15 – – – – 71⁄2 c 15 c 30 c 60 c – – 3 10 15 – – – – – – 71⁄2 15n 30n 60n 125 – 150 – – 3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac (Plug), 240 Vac (Cart.) Maximum 30 Plug D211N $ 60.00 D211NRB $ 118.00 – – 30 Cart. D221N 81.00 D221NRB 125.00 DRK 30 $17.10 60 Cart. D222N 137.00 D222NRB 217.00 RFK 03H 17.00 100 Cart. D223N 284.00 D223NRB 320.00 RFK 10 31.80 200 Cart. D224Nl 589.00 D224NRBl 800.00 HRK 1020 31.80 400 Cart. D225N 1703.00 D225NR 2306.00 DRK 40 74.00 600 Cart. D226N 3406.00 D226NR 4379.00 DRK 600 74.00 4 Wire (3 Blades and Fuseholders, 1 Neutral)—240 Vac Maximum 30 Cart. D321N $ 125.00 D321NRB $ 195.00 DRK 30 $17.10 60 Cart. D322N 217.00 D322NRB 294.00 RFK 03H 17.00 100 Cart. D323N 376.00 D323NRB 544.00 RFK 10 31.80 200 Cart. D324Nl 801.00 D324NRBl 974.00 HRK 1020 31.80 400 Cart. D325N 2075.00 D325NR 2595.00 DRK 40 74.00 400 Class T D325NT 1996.00 D325NTR 2494.00 – – 600 Cart. D326N 3882.00 D326NR 5251.00 DRK 600 74.00 600 Class T D326NT 3732.00 D326NTR 5046.00 – – 800 Class T T327N 6481.00 T327NR 8292.00 – – 11⁄2 3 71⁄2 15 – – – – – 3 71⁄2n 15n 25n 50 50 75 75 100 Not Fusible NEMA 1 Indoor NEMA 3R Rainproofa Horsepower Ratings (Max.) Catalog Number Price Catalog Number Price 1Ø 3Ø 2 Wire (2 Blades)—240 Vac Maximum 30 – DU221RBd $118.00 3 – 60 – DU222RBd 235.00 10 – 60 QO260NATSef $ 107.00 QO200TR efg 112.00 10 – 100 QO2000NSeh 184.00 QO2000NRBeh 225.00 20 – 200 Use 3-pole Switch – Use 3-pole Switch – – – 400 Use 3-pole Switch – Use 3-pole Switch – – – 600 Use 3-pole Switch – Use 3-pole Switch – – – 3 Wire (3 Blades)—240 Vac Maximum 30 DU321d $ 103.00 DU321RBd $195.00 3 71⁄2 60 DU322d 137.00 DU322RBd 295.00 10 15 100 DU323i 318.00 DU323RBi 544.00 15 30 200 DU324j 589.00 DU324RBj 974.00 15 60m 400 DU325d 1465.00 – – – 125 600 DU326k 2794.00 – – – 150 a Bolt-on hubs—Refer to page 62. b When installed, this kit rejects all but Class R fuses. When installed with this kit and Class R fuses, the switch is UL Listed for use on systems with up to 100,000 RMS symmetrical amperes available fault current. c For corner grounded delta systems only. Use switching poles for ungrounded conductors. d Suitable for use as service equipment requires field installation of a service grounding kit (page 56). e Enclosed molded case switch—Refer to page 29. f Includes factory installed grounding kit. g Not service entrance rated—Refer to page 33 for more information. h Includes factory installed neutral. i For service equipment use or when neutral is required, order part number SN0610 at $71.00. j Suitable for use as service equipment, requires field installation of neutral assembly SN20A at $133.00. k Suitable for use as service equipment requires field installation of neutral assembly D600SN at $153.00. l For 200% neutral, order (1) additional neutral kit SN20A at $133. and (1) neutral jumper kit SN20NI at $18.40. m If corner grounded delta, install neutral and use outer switching poles for ungrounded conductors. n If corner grounded delta, use outer switching poles for ungrounded conductors. System Amps D223N UL LISTED SHORT CIRCUIT WITHSTAND RATING (RMS SYMMETRICAL AMPERES) Switch Fuse Short Circuit Type Class Rating Fusible Plug 10,000 H 10,000 K 10,000 J 100,000 R 100,000 T 100,000 Not Fusible H 10,000 o K 10,000 J 100,000 R 100,000p T 100,000 o The UL Listed short-circuit current rating for Square D general duty, not fusible switches is based on the switch being used in conjunction with fuses. Evaluation of not fused switches in conjunction with molded case circuit breakers has not been performed. If a UL Listed short-circuit current rating is required, this not fused switch must be replaced with a Square D general duty fusible safety switch equipped with the appropriate class and size fusing. The UL Listed short-circuit current rating of the fusible switch is typically as follows; when used with Class H & K fuses— 10,000 A, Class R and J fuses— 100,000 A. Consult the wiring diagram of the switch to verify the UL Listed short-circuit current rating. p 50,000 amperes for 60 A not fusible switch. SAFETY SWITCHES NEMA 1 Indoor L211N Light Duty—Visible Blades 10,000 A Short Circuit Current Rating The Square D light duty enclosed switch is ideal for home applications in disconnecting power to workshops, hobby rooms, furnaces and garages. Fusible Fusible NEMA 1 Indoor Catalog Number Pricek 2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac System Amps Fuse 30 Plug L111N $35.90 Horsepower Ratings Std. Max. 1⁄2 NEMA 1 Indoor Catalog Number Pricek 3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac System Amps Fuse 30 Plug L211N Horsepower Ratings Std. Max. $47.80 11⁄2q 3q 65.00 11⁄2 q 3q 2 30 Cart. L221N q For single phase hp rating, use two switching poles. © 2004 Schneider Electric All Rights Reserved 6/7/04 kDE1A DE2A Discount Schedule 55 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz General Duty Safety Switches Accessories, Lug Data and Dimensions Class 3130 www.SquareD.com For the most up-to-date information Field Installable Electrical Interlock Kits Field Installable Fuse Puller Kits Electrical interlocks for Series F 100–200 A general duty safety switches and Series F 60 A fusible general duty safety switches are available in kit form for field installation. Each kit contains instructions for proper field mounting. A pivot arm operates from switch mechanism, breaking the control circuit before the main switch blades break. Switches with electrical interlocks installed are UL Listed. Electrical Interlock Kit Kit consists of three fuse pullers as required for a 3-pole, fusible, 60 and 100 ampere general duty switch. Kits can be installed in 60 and 100 ampere Series F switches. Switch Ampere Rating Electrical Interlock Kit Catalog Numbera Fusible Series F 60 EIK031 or EIK032 Series F 100–200 EIK1 or EIK2 Description Series F 60 Ampere Fuse Puller Kit Series F 100 Ampere Fuse Puller Kit Catalog Number FPK03 FPK0610 Price $20.00 28.40 Field Installable Service Grounding Kits Switch Ampere Rating Catalog Number Price 30 PK3GTA1 $ 7.60u Series E 60 PK3GTA1 7.60u Series F 60 GTK03 7.60 100 200 400 600 800 GTK0610 PKOGTA2 PKOGTA2 (Two Required) PKOGTA3 12.60 36.80 Wire Size AWG (2) #12 Cu or (2) #10 Al or (1) #4 Al/Cu Max. (2) #12 Cu or (2) #10 Al or (1) #4 Al/Cu Max. (2) #12 Cu or (2) #10 Al or (1) #4 Al/Cu Max. (2) #1/0 Al/Cu Max. (2) #2/0 Al/Cu Max. (2) #2/0 Al/Cu Max. Per Lug (6) #3/0 Al/Cu Max. Price $145. 207. a Electrical interlock kit catalog numbers with -1 suffix indicates one normally open and one normally closed contact; -2 indicates two normally open and two normally closed contacts. Kits are UL Listed. Field Installable Class J Fuse Kit Kit consists of three Class J fuse adapters as required for 3-Pole, fusible 600 A General Duty switch. Kit can be installed in 600 A series E3 switches only (NEMA 1). Switch Ampere Rating Class J Kit Catalog Number Price 600 A Series E3 GDJK600 $195. 36.80 82.00 Terminal Lug Data b Ampere Rating W Wire Range Conductors Wire Bending Space Per NEC Table 373-6 Per Phase AWG/kcmil 30 60 100 200 400 NEMA 1 1 1 1 1 1 or 2 #12–6 (Al) or #14–6 (Cu) #10–3 (Al) or #14–3 (Cu) #12–1 (Al) or #14–1 (Cu) #6 –250 (Al/Cu) #1/0 –600 (Al/Cu) or #1/0 –300 (Al/Cu) 400 NEMA 3R 2 #1/0–250 (Al/Cu) 600 800 2 3 #4 –500 (Al/Cu) #3/0 –500 (Al/Cu) H Lug Wire Range AWG/kcmil #12–6 (Al) or #14–6 (Cu) #10–2 (Al) or #14–2 (Cu) #12–1/0 (Al) or #14–1/0 (Cu) #6 –300 (Al/Cu) (1) #1/0 –750 (Al/Cu) or (2) #1/0 –300 (Al/Cu) (1) #1 –600 (Al/Cu) or (2) #1/0 –250 (Al/Cu) #4 –600 (Al/Cu) #3/0 –500 (Al/Cu) b 30–100 A switches suitable for 60°C or 75°C conductors. 200–800 A switches suitable for 75°C conductors. W/H D Field Installable Lug Kit Kit consists of three line, three load and two neutral lugs as required for a 3-pole 400 A or 600 A general duty switch. Kit can be installed on 400 or 600 A Series E3 switches. This kit applicable to NEMA 1 enclosures only. Switch Ampere Rating Lug Kit Catalog Number Wire Range/NEC AWG/kcmil Lug Wire Range AWG/kcmil Price GD4060LK (1) 1/0–600 (2) 1/0–500 (4) 1/0–250 (2) 1/0–600 (4) 1/0–250 $269. 400 or 600 A Series E3 SAFETY SWITCHES Approximate Dimensions Catalog Number L111N L211N L221N D211Nc D211NRBc D221Nc D221NRBc D222N D222NRB D223N D223NRB D224N D224NRB D225N D225NR D226Nc D226NRc D321Nc D321NRBc D322N D322NRB D323N D323NRB D324N D324NRB D325Nc D325NTc D325NRc Series E2 E2 E2 E3 E2 E3 E3 F1 F1 F3 F3 F1 F1 E3 E1 E3 E1 E3 E3 F1 F1 F3 F3 F1 F1 E3 E3 E1 H IN 7.63 7.63 7.63 9.25 9.63 9.25 9.63 14.63 14.88 17.50 17.50 29.00 29.25 45.12 30.63 49.13 49.13 9.25 9.63 14.63 14.88 17.50 17.50 29.00 29.25 45.12 45.12 30.63 mm 194 194 194 235 245 235 245 372 378 445 445 737 743 1146 778 1248 1248 235 245 372 378 445 445 737 743 1146 1146 778 W IN 5.00 5.00 5.00 6.75 7.25 6.75 7.25 6.50 6.63 8.50 8.50 17.25 17.25 24.00 21.38 24.00 24.75 6.75 7.25 6.50 6.63 8.50 8.50 17.25 17.25 24.00 24.00 21.38 mm 127 127 127 171 184 171 184 165 168 216 216 438 438 610 543 610 629 171 184 165 168 216 216 438 438 610 610 543 W/H D IN mm IN 6.13 156 4.00 6.13 156 4.00 6.13 156 4.00 7.25 184 3.63 7.75 197 3.75 7.25 184 3.63 7.75 197 3.75 7.45 189 4.88 7.45 189 4.88 10.50 267 6.50 10.50 267 6.50 19.00 483 8.25 19.00 483 8.25 24.88 632 8.88 22.25 565 10.13 24.88 632 8.88 25.13 638 8.88 7.25 184 3.63 7.75 197 3.75 7.45 189 4.88 7.45 189 4.88 10.50 267 6.50 10.50 267 6.50 19.00 483 8.25 19.00 483 8.25 24.88 632 8.88 24.88 632 8.88 22.25 565 10.13 Std. mm Pack 102 1 102 1 102 1 92 5 95 5 92 5 95 5 124 1 124 1 165 1 165 1 210 1 210 1 226 1 257 1 226 1 226 1 92 5 95 5 124 1 124 1 165 1 165 1 210 1 210 1 226 1 226 1 257 1 Catalog Number Series H W mm IN 778 21.38 1248 24.00 1248 24.00 W/H D mm IN mm IN 543 22.25 565 10.13 610 24.88 632 8.88 610 24.88 632 8.88 mm 257 226 226 1 1 1 1248 24.75 1246 24.75 245 7.25 245 7.25 629 25.13 629 25.13 184 7.75 184 7.75 638 638 197 197 8.88 8.88 3.75 3.75 226 226 95 95 1 1 5 5 Std. Pack D325NTRc D326Nc D326NTc E1 E3 E3 IN 30.63 49.13 49.13 D326NRc D326NTRc DU221RBc DU222RBc E1 E1 E2 E1 49.13 49.13 9.63 9.63 DU321c DU321RBc E2 E2 9.25 9.63 235 245 6.75 7.25 171 184 7.25 7.75 184 197 3.63 3.75 92 5 95 5 DU322c DU322RBc E1 E1 9.25 9.63 235 245 6.75 7.25 171 184 7.25 7.75 184 197 3.63 3.75 92 5 95 5 DU323 DU323RB DU324 DU324RB F3 F3 F1 F1 17.50 17.50 29.00 29.25 445 8.50 445 8.50 737 17.25 743 17.25 216 216 438 438 10.50 10.50 19.00 19.00 267 267 483 483 6.50 6.50 8.25 8.25 165 165 210 210 DU325c DU326c E3 E3 45.12 49.13 1146 24.00 1248 24.00 610 24.88 610 24.88 632 632 8.88 8.88 226 1 226 1 QO200TRc QO260NATSc QO2000NRBc QO2000NSc G3 E2 E1 E1 6.50 9.25 14.00 13.38 118 124 197 156 ... ... ... ... 3.88 3.25 4.50 3.50 99 83 114 89 T327Nc T327NRc E1 E1 49.13 49.13 632 638 8.88 8.88 226 1 226 1 165 235 356 340 4.63 4.88 7.75 6.13 1248 24.00 1248 24.75 ... ... ... ... 610 24.88 629 25.13 1 1 1 1 5 1 1 1 c Does not have a cover draw as indicated in above drawing. 56 uDE3A DE1 Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Double Throw Safety Switches Fusible and Not Fusible Class 3140 www.SquareD.com For the most up-to-date information New—Series F 30–100 A Types DT, DTU (Series F) • Fusible (DT) and not fusible (DTU) switches available. • Manually operated switch suitable for use in accordance with article 702 of the NEC, ANSI/NFPA 70. • Standards: UL 98, NEMA KS1, CSA, and NOM • Modular design—switch handle, lock-plate, switch mechanism, line and load bases are field replaceable. • UL listed short circuit current ratings up to 200,000 A (using Class R, J, or T fuses—see table for rating). • Load make/break rated. • Meets NEMA hp ratings. • Dual cover interlock. • May be padlocked ON or OFF. • Lock-off accepts up to three padlocks. • Side-opening door. • Quick make/quick break mechanism. • Meets NEMA requirements as heavy duty switch. (Note: handle is all black) • Electrical interlock kits field installable. • Neutral assembly kits field installable (2 and 3-pole switches). • UL Listed as suitable for use as service equipment. • Supplied as standard for switching one load between two power sources, and may be field converted to switch one power source between two loads. 30–100 A DT, DTU (Series F5) NEMA 1 DTU (Series E) 200 A NEMA 3R 82,000 and 92,000 Line NEMA 1 92251 © 2004 Schneider Electric All Rights Reserved 6/7/04 • Not fusible • Designed for manual transfer of loads from one supply to another. • UL Listed switches are suitable for use in accordance with Article 702 of the National Electrical Code, ANSI/NFPA 70. • All 82,000–92,000 and DTU double throw switches are continuous duty rated for their nameplate ampere rating. • The 82,000 and DTU (Series E) switches are load make/break rated. • The 92,000 switches are not load make/break rated and should be used for isolating purposes only. • UL Listed as suitable for use as service equipment except as footnoted. • Horsepower rated only as footnoted. • All accessories, except service ground kits, require factory installation. • For application above 600 amperes, see Supplemental Digest. For additional information, reference Catalog #3100CT9801. 57 SAFETY SWITCHES 30 (Series T4), 200–600 A Types 82,000, 92,000 and 200 A DTU (Series E) Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Double Throw Safety Switches 240 Volt Class 3140 www.SquareD.com For the most up-to-date information NEMA 4,4X,5 Stainless NEMA 3R NEMA 12 Gasketed 240 Vac Std. Catalog No. Price Catalog No. Max. 250 Vdc c Current Series System Ampere Rating Horsepower Ratings ai NEMA 1 Price Catalog No. Price Catalog No. Price 1Ø 3Ø 1Ø 3Ø 15 b 15 30 b 20 Fusible 2-Pole, 240 Vac—250 Vdc Line 100 F DT223 $1586. DT223RB $2037. ... ... ... ... 7.5 F F F DT321 DT322 DT323 1097. 1313. 2069. DT321RB DT322RB DT323RB 1477. 1741. 2483. ... ... ... ... ... ... ... ... ... ... ... ... 1.5d 3d 7.5d 3b 7.5 b 15 b 3d 10d 15d 7.5 b 15 b 30 b 5 10 20 60 100 F F DTU222 DTU223 ... $ 898. ... ... ... ... ... ... ... ... ... ... ... ... 10 15 ... ... 10e 20e 30 200 200 400 T4 E E E 92251f 82254 82254NW 92255 f 390. 1210. 1914. 3548. ... DTU224NRB fj ... 92255R f ... 1451. ... 5251. ... ... ... ... ... ... ... ... ... H82254 ... H92255 f ... $3114. ... 6259. ... 15 15 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 30 60 100 F F F DTU321 DTU322 DTU323 536. 746. 1176. ... ... DTU323RB ... ... 1302. ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 3b ... ... 5d 10d 15d 10b 15b 30b 5e 10e 20e 30 200 200 400 600 T4 E E E E 92351f 82354f DTU324Nfj 92355f 92356 c 458. 1709. 1865. 4874. 6605. ... DTU324NRBfj ... 92355Rf 92356R f ... 2003. ... 8692. 9081. ... ... ... ... ... ... ... ... ... ... ... H82354f ... H92355f H92356 ... 3605. ... 7100. 9508. ... ... ... ... ... ... 15 15 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 30 200 400 600 T4 E E E 92451f 92454 g 92455 92456 635. 2811. 6389. 7683. ... 92454RB g 92455R 92456R ... 5011. 9012. 9904. ... ... ... ... ... ... ... ... ... H82454 g H92455 H92456 h ... 4519. 8860. 10641. ... ... ... ... ... 15 g ... ... ... ... ... ... ... ... ... ... ... ... ... ... Line Load 3-Pole, 240 Vac—250 Vdc Line Line 30 60 100 Load Not Fusible 2-Pole, 240 Vac—250 Vdc Line Line $ 641. 914. ... DTU223RB Load 3-Pole, 240 Vac—250 Vdc Line SAFETY SWITCHES Line Load 4-Pole, 240 Vac a b c d e f g h i j Refer to page 6-35 for additional motor application data. The starting current of motors or more than standard horsepower may require the use of fuses with appropriate time delay characteristics.b If used on corner grounded delta systems, install neutral and use outer switching pole for ungrounded conductors.b For switching dc, use two switching poles.. Use outer switching poles. Maximum rating. 240 Vac onlyb 240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 58 Hp rating applies only to H82454. (92454, 92454RB are not Hp rated)b Not UL listed or suitable for use as service equipment.b Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 59 Std.—Using fast acting one time fuses. Max.—Using dual element time delay fuses. Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60 Neutral included with device. Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . . page 61 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 62 For additional information, reference Catalog #3100CT9801. 58 DE1 Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Double Throw Safety Switches Application Data Class 3140 www.SquareD.com For the most up-to-date information Situations Requiring Fuses: UL Listed Short Circuit Current Ratings 30–100 A Type DT (Series F): Select DT switches from page 58 which have provisions for accepting fuses. 30, 200–600 A Type 82,000, 92,000 (Series E, T4), all DTU devices: Use the not fused double throw switches from page 58 in conjunction with standard fused devices, and install them according to the below diagram 1 or 2. Line Ampere Rating Voltage Rating Type DT (Series F) 30–100 A 240 V Type DTUb (Series F) 30–100 A 240 V DTU224NRB and DTU324NRB (Series E) 200 A 240 V DTU324N (Series E) 200 A 240 V Switch Type Type 82,000 all Type 92,000 all UL Listed Fuse Class H, K 10,000 R, J 200,000 H or K R or J H, K H, K R, J H, K 240 V Short Circuit Current Ratinga (RMS Symmetrical Amperes) R, J 10,000c 200,000 10,000c 10,000c 100,000 10,000c 100,000 600 V H, K 10,000c 240 V H, K 10,000c a Rating applies to AC only. The UL Listed short circuit current rating for Not Fusible switches is based on the switch being used in conjunction with the corresponding fuse type. Evaluation of Not Fusible switches in conjunction with molded case circuit breakers has not been performed. b The DTU361 and DTU361RB are also suitable for use on a circuit capable of delivering not more than (A) 18,000 rms summetrical A, 600 Vac maximum when protected by Type FH circuit breaker rated 30 A maximum or (B) 14,000 rms symmetrical A, 600 Vac maximum when protected by Type FA circuit breaker rated 30 A maximum. c Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used ahead of an unfused safety switch when there is up to 10,000 A short circuit current available. Terminal Lug Data for Type DT, DTU (Series F) Double Throw Safety Switches Not-Fusible D/T Switch NEMA 1, 3R, 4, 4X, 12 Line Fusible Single Throw Switch or Circuit Breaker Wire Range Wire Bending Space Per NEC Table 373-6 AWG/kcmil Al/Cu Standard Lug Wire Range AWG/kcmil Al/Cu Optional Compression Lug Field Installable Switch Ampere Rating Wires per Phase 30–60 A Type DT, DTU (Series F) 1 #12–2 (Al) or #14–2 (Cu) #12–2 (Al) or #14–2 (Cu) C10-14, D8-14, or E6-14d 1 #12–1/0 (Al) or #14–1/0 (Cu) #12–1/0 (Al) or #14–1/0 (Cu) VCEL02114S1e 100 A Type DT, DTU (Series F) See Digest 173 pages 3-11 and 3-13 for appropriate kit. Order 2 kits per switch. Terminal Lug Data for Types 82,000, 92,000 and for E-Series DTU devices f Diagram 1 Ampere Rating Wires per Phase Wire Range Wire Bending Space Per NEC Table 373-6 AWG/kcmil Al/Cu Lug Wire Range AWG/kcmil Al/Cu Optional Compression Lugs Field Installable 30 A (Series T4)g 1 #14–8 #12–2 (Al) or #14–2 (Cu) ... 200 1 #6–300 #6–300 VCEL030516H1e 400 2 #4–250 #4–350 ... 600 2 #4–500 #4–600 ... Line Fusible Single Throw Switch or Circuit Breaker Not-Fusible D/T Switch d e f g Thomas and Betts catalog numbers. VERSA-CRIMP® catalog numbers. 200–600 A switches suitable for 75° C conductors. 30 A switches suitable for 60° C or 75° C conductors. SAFETY SWITCHES Load Load Optional Copper Only Lug Fusible Single Throw Switch or Circuit Breaker Line Diagram 2 240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 58 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 59 Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 60 Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . .page 61 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 62 For additional information, reference Catalog #3100CT9801. © 2004 Schneider Electric All Rights Reserved 6/7/04 DE1 Discount Schedule 59 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Double Throw Safety Switches Dimensions—Series F Devices Class 3140 www.SquareD.com For the most up-to-date information 30–100 A Type DT, DTU (Series F)—Approximate Dimensions W Catalog Number H Series H W W/H D IN mm IN mm IN mm IN mm DT223 DT223RB DT321 DT321RB DT322 F5 F5 F5 F5 F5 38.00 38.00 38.00 38.00 38.00 965 965 965 965 965 9.88 6.87 10.25 10.25 10.25 251 174 260 260 260 11.13 8.12 11.50 11.80 11.50 283 206 292 300 292 6.75 6.60 6.75 6.60 6.75 171 168 171 168 171 DT322RB DT323 DT323RB DTU222 DTU223 F5 F5 F5 F5 F5 38.00 38.00 38.00 29.94 29.94 965 965 965 760 760 10.25 9.88 6.87 10.25 10.25 260 251 174 260 260 11.80 11.13 8.12 11.96 11.96 300 283 206 304 304 6.60 6.75 6.60 6.93 6.93 168 171 168 176 176 DTU223RB DTU321 DTU322 DTU323 DTU323RB F5 F5 F5 F5 F5 30.50 29.94 29.94 29.94 30.50 775 760 760 760 775 10.25 10.25 10.25 10.25 10.25 260 260 260 260 260 11.96 11.96 11.96 11.96 11.96 304 304 304 304 304 6.93 6.93 6.93 6.93 6.93 176 176 176 176 176 D W/H NEMA 1 W H W/H D SAFETY SWITCHES NEMA 3R 240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 58 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 59 Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60 Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . . page 61 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 62 For additional information, reference Catalog #3100CT9801. 60 © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Double Throw Safety Switches Dimensions—Series E, T4 Devices Class 3140 www.SquareD.com For the most up-to-date information W/H W D 30, 200–600 A Types 82,000, 92,000 and E-Series DTU devices, NEMA 1 and 3R—Approximate Dimensions Catalog Number H NEMA 1 W/H W Series H W W/H D IN mm IN mm IN mm IN mm DTU224NRB DTU324N DTU324NRB 82254 82254NW E1 E1 E1 E1 E1 32.50 32.50 32.50 30.88 30.88 826 826 826 784 784 20.63 23.50 24.13 15.75 20.00 524 597 613 400 508 24.00 26.85 26.25 19.63 23.88 610 682 667 499 607 10.63 10.63 10.63 9.75 11.75 270 270 270 248 298 82354 92251 92255 92255R 92351 E1 T4 E1 E1 T4 30.88 10.00 31.50 31.25 10.00 784 254 800 794 254 20.00 8.00 21.00 30.13 8.00 508 203 533 765 203 23.88 9.75 24.25 33.00 9.75 607 248 616 838 248 11.75 4.75 14.13 11.38 4.75 298 121 359 289 121 92355 92355R 92356 92356R 92451 E1 E1 E1 E1 T4 31.50 31.25 53.00 52.63 10.00 800 794 1346 1337 254 29.38 30.13 34.25 34.38 10.00 746 765 870 873 254 32.63 33.00 37.50 37.63 11.75 829 838 953 956 298 14.13 11.38 16.38 13.88 4.75 359 289 416 353 121 92454 92454RB 92455 92455R 92456 E1 E1 E1 E1 E1 31.13 30.78 31.50 31.20 53.00 791 782 800 792 1346 24.75 20.50 37.75 35.65 44.25 629 521 959 906 1124 28.25 28.00 41.13 38.52 47.50 718 711 1045 978 1207 11.75 10.62 14.13 10.90 16.38 298 270 359 277 416 92456R E1 52.50 1334 43.70 1110 48.00 1219 13.50 343 D H SAFETY SWITCHES DTU—200 A NEMA 3R 240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 58 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 59 Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 60 Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . .page 61 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 62 For additional information, reference Catalog #3100CT9801. © 2004 Schneider Electric All Rights Reserved 6/7/04 61 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Double Throw Safety Switches Accessories Class 3140 www.SquareD.com For the most up-to-date information Neutral Assembly For 2 and 3-Pole Switches Only Switch Ampere Rating 30–100 A Type DT, DTU (Series F) Field Installed Standard Neutral Kit Catalog No. Terminal Data AWG/kcmil SN0310 Price #14–1/0 Al/Cu $ 76. Service Grounding Kit (Required for service equipment use.) Field Installed Copper only Neutral Kit Catalog No. Terminal Data AWG/kcmil SN0310C Switch Ampere Rating Field Installed Service Ground Lug Kit Catalog Number Terminal Data AWG/kcmil Price 30–100 A Type DT, DTU (Series F) Included Included std. 30 A Type 92,000 DT30SG (4) #14–4 Cu/Al 200 A Type 82000, 92,000 and DTU (Series E) DT100SG (3) #14–1/0 Cu/Al 20.00 400–600 A Type 82000, 92,000 PKOGTA2 (2 required) (4) #10–2/0 Cu or (4) #6–2/0 Al 35.00 Price #14–1/0 Cu $ 80. 30 A (Series T4) a a 605. ... ... ... 200 A Type 82000, 92,000 and DTU (Series E) a a 740. a a 740. 400–600 A Type 82000, 92,000 a a 948. a a 948. a For Type 82,000 and 92,000 switches, neutral is available factory installed on 2 and 3-pole double throw switches. Not UL Listed. To order, add suffix N to the standard catalog number and add the above price to the list price of the switch. For DTU (Series E) switches, neutral is factory installed in standard device and is UL Listed. $19.60 Class R Fuse Kits When installed, this kit rejects all but Class R fuses. Kits are available for field installation. For factory installation, add “CLR” suffix to catalog number. Electrical Interlocks Switch Ampere Rating Field Installed Electrical Interlock Kit Catalog Numberb Price Factory Installed Price Adder Per Switch EIK1, EIK2c $207. $603.d 200 A Type 82000, 92,000 and DTU (series E) ... ... 742.e 400–600 A Type 82000, 92,000 ... ... 932. e 30–100 A Type DT, DTU (series F) Switch Ampere Rating Class R Fuse Kit Catalog Number Series Number Factory Installed Price Price Class R Fuse Kits—240 V (two kits per 3-pole switch) 30 60 100 F5 F5 F5 RFK03 RFK06 RFK10 $16.30 17.00 31.80 $260.00 260.00 260.00 Class R Fuse Kits—600 V (two kits per 3-pole switch) 30 60 100 b Electrical interlock kit catalog numbers with “1” suffix indicate one normally open and normally closed contact; “2” indicates two normally open and two normally closed contacts. See Digest 173 page 3-9 for electrical interlock ratings. c 30–100 A Type DT, DTU (Series F) switches contain (2) separate switching mechanisms. Each mechanism will accept an electrical interlock. Some applications may therefore require (2) electrical interlocks. d 30–100A Type DT, DTU (Series F) switches with factory installed electrical interlocks installed are UL Listed and interlocks are furnished with 2 N.O. /2 N.C. contacts installed in both “ON” positions. To order, add suffix EI to standard catalog number. e Type 82,000 and 92,000, and DTU (Series E) switches are available with electrical interlock factory installed only. Not UL Listed. Electrical interlocks are furnished with 2 N.O. /2 N.C. contacts and are installed in both “ON” positions. To order, add suffix EI to standard catalog number. F5 F5 F5 RFK06 RFK06H RFK10 17.00 17.00 31.80 260.00 260.00 260.00 Lock-On Provisions—UL Listed 30–100 A type DT, DTU (Series F) and type 92,000 included on standard device. Type 82,000 and 200 A DTU (Series E): available factory installed. Add SPLO to catalog number and add $273. to list price. Rainproof Bolt-On Hubs—For Use On NEMA 3R Enclosures SAFETY SWITCHES “RB Hub” Conduit Size Hub Cat. No. Price Each r B075 B100 B125 B150 B200 B250 B300 B350 B400 Closing Cap BCAP $23.30 $23.30 $23.30 $23.30 $42.90 $71.00 $130.00 $200.00 $245.00 $2.50 3⁄4 11⁄4 1 11⁄2 21⁄2 2 31⁄2 3 4 NEMA 3R rainproof enclosures with catalog number ending in RB have a bolt-on closing cap factory installed. Order bolt-on hubs separately from table above. For more details see page 20. Hubs thru size 21⁄2 can be directly installed on RB devices. Devices requiring 3" or larger hubs must have holes cut in the field. Gaskets are provided on 3" and larger hubs. All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread. Watertight Hubs—For Use On NEMA 4, 4X and 5 Stainless Steel and NEMA 12 Enclosures 1⁄2 Conduit Trade Size Standard-Zinc H050 Hub Catalog Number Zinc Price Each $20.70 Chrome Plated H050CP Hub Catalog Number Chrome Plated Price Each 27.10 3⁄4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4 H075 H100 H125 H150 H200 H250 H300 H350 H400 $30.00 $31.40 $36.00 $55.00 $80.00 $ 92.00 $118.00 $188.00 $254.00 H075CP H100CP H125CP H150CP H200CP H250CP H300CP H350CP H400CP 37.60 42.90 44.60 64.00 91.00 123.00 162.00 237.00 272.00 240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 58 Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 59 Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60 Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . . page 61 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 62 For additional information, reference Catalog #3100CT9801. 62 DE1 rDE1A Discount Schedule © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Warranties Square D Residential Products A. Limited Warranties — 1. Square D Single Phase Load Centers and Combination Service Entrance Devices. Square D warrants its single phase load centers and combination service entrance devices to be free from defects in material and workmanship, under normal care and proper usage in a residential installation, for a period of ten (10) years from the date of installation. If the product fails within the warranty period because of a defect in material or workmanship, Square D will, at its option, repair or replace the defective part or parts upon following the notice procedures below and return of product to place of purchase. 2. Square D Load Center Branch Circuit Breakers. Square D warrants its branch circuit breakers to be free from defects in material and workmanship under normal care and proper usage in a residential installation, for the lifetime of the load center in which it is installed. If the circuit breaker fails within the warranty period because of a defect in material or workmanship, Square D will replace the defective breaker free of charge upon following the notice procedures below and return of the product to place of purchase. B. Exclusive Remedy — The repair and/or replacement of defective products is your sole and exclusive remedy. C. Warranty Redemption and Exclusions — 1. Square D must be given prompt written notice of any defect or failure of any product covered by these limited warranties at the following address: Square D Company, 1415 S. Roselle Road, Palatine, Illinois, 60067, (888) 778-2733, weekdays between the hours of 8:00 a.m. and 5:00 p.m. Eastern Time. For warranty redemption, you must return the product to Square D at the above address. 2. Any product returned under these limited warranties, if shipped, must be sent freight costs prepaid. Square D will deliver repaired or replaced products to buyer, freight costs prepaid. Repaired or replaced products shall be warranted hereunder only for the unexpired portion of the original warranty period. This warranty does not include costs or reimbursement for labor. Any limited warranties granted or liabilities assumed hereunder will not apply to products that have been damaged, altered, repaired or operated otherwise than in conformity with the requirements for safe operation and maintenance. For your safety and to provide optimum short circuit protection, Square D recommends that you use only the Square D circuit breakers identified on the load center or combination service entrance device label or wiring diagram. Square D disclaims all liability for damage, injury or non-performance caused by the use or failure of incompatible or UL Classified circuit breakers. D. Disclaimer of All Other Warranties — EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE OR ANY WARRANTIES IMPLIED BY LAW, Square D MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES. TO THE FULLEST EXTENT PERMITTED BY LAW, Square D DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING DISCLAIMER MAY NOT APPLY TO YOU DEPENDING UPON THE PRODUCT YOU PURCHASE, THE APPLICATION AND USE OF YOUR PRODUCT, OR YOUR STATUS AS A CONSUMER. TO THE EXTENT YOU ARE ENTITLED TO RECOVER UNDER AN IMPLIED WARRANTY, THE DURATION OF THAT IMPLIED WARRANTY SHALL BE THE PERIOD OF THE EXPRESS LIMITED WARRANTY SET FORTH ABOVE. E. Limitation of Liability — Square D expressly disclaims any and all liability to you for any consequential or incidental damages, damages for loss of use, loss of profits, income or revenue, loss of time or inconvenience, loss or damage to associated equipment, damages to tangible or intangible property, other than the equipment covered by this limited warranty, cost of substituted or replacement equipment other than as expressly warranted, damages associated with excessive overvoltages, obsolescence, abuse, misuse, non-authorized modification, alteration or catastrophic events, or any other incidental, consequential or special damage arising out of the use of the products. Square D shall not be liable for indirect, special, incidental or consequential damages with respect to the sale of the products, including any lost revenue or profits, consequential and/or incidental damages, business interruption or damage to business reputation, regardless of the theory upon which any claim may be based, including any statutory, tort contract or insurance subrogation causes of action or claims. In no event will Square D’s entire liability to you, including any liability in the event the exclusive remedy set forth in this agreement fails of its essential purpose, exceed the purchase price for the affected products. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the preceding limitations or exclusions may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from State to State. © 2004 Schneider Electric All Rights Reserved 6/7/04 63 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Warranties Square D Structured Wiring A. Limited Warranty — Square D warrants to customers purchasing through authorized Square D distributors that the Square D® labeled passive (enclosure, cover and any non-powered module) structured wiring products (“passive components”) at the time of sale by Square D are free from defects in materials and workmanship. Square D also warrants that the Square D labeled active (any powered module) structured wiring products (“active components”) at the time of sale by Square D are free from defects in materials and workmanship. B. Exclusions and Exclusive Remedy — If within the applicable warranty period, purchaser discovers that a product subject to this Limited Warranty was not as warranted and promptly notifies Square D in writing, Square D shall repair or replace the product or refund the purchase price, at Square D’s option. This warranty shall not apply (a) to equipment not supplied by Square D, (b) to equipment or product which shall have been improperly repaired or altered or modified in a non-authorized manner, (c) to equipment or products which shall have been subjected to negligence, misuse, accident, or damage by circumstances beyond Square D’s control, or to improper operation, maintenance or storage, or to other than normal use or service. The foregoing limited warranties do not cover reimbursement for labor, transportation, removal, installation, or other expenses that may be incurred in connection with repair or replacement. This Limited Warranty is your sole and exclusive remedy. C. Warranty Period — For active components, this Limited Warranty shall be in effect until five (5) years following the date of purchase, or until four (4) years following the house closing by the original owner. For passive components, this Limited Warranty shall be in effect until fifteen (15) years following the date of purchase, or until fourteen (14) years following the house closing by the original owner. D. Warranty Transferable — The unexpired portion of this warranty can be transferred to the subsequent homeowner. E. Claims Procedure — Send either (1) the original dated sales receipts of the product or (2) the dated documentation of the original owner’s house closing or (3) original Certificate of Occupancy along with the damaged product to Square D Company, 8001 Highway 64 East, Knightdale, NC 27545, Attn: Multi-Link Device Warranty. Note: If these documents are unavailable, the product may be returned to the address above, and the earliest identifiable date code stamped on the product will be used to determine if the product is subject to the conditions and terms of this express warranty. F. Disclaimer of All Other Warranties — EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE OR ANY WARRANTIES IMPLIED BY LAW, Square D MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES. TO THE FULLEST EXTENT PERMITTED BY LAW, Square D DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING DISCLAIMER MAY NOT APPLY TO YOU DEPENDING UPON THE PRODUCT YOU PURCHASE, THE APPLICATION AND USE OF YOUR PRODUCT, OR YOUR STATUS AS A CONSUMER. TO THE EXTENT YOU ARE ENTITLED TO RECOVER UNDER AN IMPLIED WARRANTY, THE DURATION OF THAT IMPLIED WARRANTY SHALL BE THE PERIOD OF THE EXPRESS LIMITED WARRANTY SET FORTH ABOVE. G. Limitation of Liability — Square D expressly disclaims any and all liability to you for any consequential or incidental damages, damages for loss of use, loss of profits, income or revenue, loss of time or inconvenience, loss or damage to associated equipment, damages to tangible or intangible property, other than the equipment covered by this limited warranty, cost of substituted or replacement equipment other than as expressly warranted, damages associated with excessive overvoltages, obsolescence, abuse, misuse, non-authorized modification, alteration or catastrophic events, or any other incidental, consequential or special damage arising out of the use of the products. Square D shall not be liable for indirect, special, incidental or consequential damages with respect to the sale of the products, including any lost revenue or profits, consequential and/or incidental damages, business interruption or damage to business reputation, regardless of the theory upon which any claim may be based, including any statutory, tort contract or insurance subrogation causes of action or claims. In no event will Square D’s entire liability to you, including any liability in the event the exclusive remedy set forth in this agreement fails of its essential purpose, exceed the purchase price for the affected products. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the preceding limitations or exclusions may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights, which vary from State to State. 64 © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Square D Conditions Of Sale NOTE: The following Conditions of Sale are subject to change. All transactions for all products sold by Square D Company, including Square D brand products and all Schneider Electric brand products, such as Merlin Gerin, Modicon and Telemecanique brand products, are subject to the latest published Conditions of Sale of the Square D Company and to any Special Conditions of Sale which may be contained in applicable Square D quotations and acknowledgments. 1. GOVERNING PROVISIONS AND ACCEPTANCE: All quotations are subject to these conditions of sale. Acceptance of an order by Square D shall be expressly conditioned on Purchaser’s assent to these conditions. Purchaser’s direction to proceed with engineering, manufacture or shipment by Square D shall be deemed evidence of this assent. No modified or other conditions will be applicable unless those conditions are so stated in Square D’s proposal or are specifically agreed to in writing and signed by an authorized official of Square D. Failure to object to provisions contained in any Purchase Order or other communication from the Purchaser (including, without limitation, penalty clauses of any kind) shall not be construed as a waiver of these Conditions nor an acceptance of any other provisions. These terms are a complete statement of the parties’ agreement and may only be modified in writing signed by both parties. These terms may not be modified by course of dealing, course of performance or usage of trade. These terms supersede all previous written or oral quotations, statements or agreements. Any contract for sale by and between the parties shall be governed by and construed according to the laws of the State of Illinois without regard to its rules on the conflict of laws. The Convention on the International Sale of Goods is expressly excluded. 2. QUOTATIONS: Written quotations shall be valid for no more than thirty (30) days from their date, unless otherwise stated in the quotation. All quotations are subject to change by Square D Company at any time upon notice to Purchaser. It is Purchaser’s obligation to review the quotation carefully and to immediately advise Square D in writing of any differing interpretation Purchaser has so any necessary change can be made. 3. PRICE POLICY: All prices are subject to change without notice. In the event of a net price change and unless otherwise agreed to in writing, prices for orders scheduled for immediate release shall be those in effect at time of order entry. Prices for orders placed for future shipment without an agreed price and ship date will be billed at the pricing in effect as of the shipment date. All clerical errors are subject to correction. 4. SUBSTITUTION: Square D may furnish suitable substitutes for material unobtainable because of priorities or regulations established by governmental authority or nonavailability of materials from suppliers, provided such substitutions do not adversely affect the technical soundness of the equipment. Square D assumes no liability for deviation from published dimensions and descriptive information not essential to proper performance of the product. 5. TAXES: Any manufacturer’s tax, retailer’s tax, occupation tax, use tax, sales tax, excise tax, (except federal excise tax © 2004 Schneider Electric All Rights Reserved 6/7/04 on vehicles), duty, customs, inspecting or testing fee, or other tax, fee or charge of any nature whatsoever, imposed by any governmental authority or measured by any transaction between Square D and Purchaser, shall be paid by the Purchaser in addition to the prices quoted or invoiced, and such charges will appear as a separate line item on the invoice. In the event Square D will be required to pay any such tax, fee, or charge, Purchaser shall reimburse Square D or, in lieu of such payment, Purchaser shall supply Square D at the time the order is submitted with an exemption certificate or other document acceptable to the tax authority. Purchase Orders must state the existence and amount of any such tax, fee or charge for which Purchaser claims an exemption. 6. TERMS OF PAYMENT: Acceptance of all Purchase Orders is subject to Purchaser meeting Square D credit standards. Terms are subject to change for failure to meet such standards. Terms are net thirty (30) days from date of invoice of each shipment, unless otherwise stated in Square D’s quotation. For an authorized distributor or authorized reseller order, applicable terms of payment are stated in the quotation or applicable discount schedule. Square D reserves the right at any time to demand full or partial payment before proceeding with a contract of sale if, in its sole judgment, as a result of changes in the financial condition of the Purchaser the terms of payment originally specified are no longer justified. 7. PAYMENTS: If delivery is delayed or deferred by the Purchaser beyond the scheduled date, payment shall be due in full when Square D is prepared to ship. The equipment may be stored at the risk and expense of the Purchaser. If the Purchaser defaults when any payment is due, then the whole contract price shall become due and payable upon demand, or Square D at its option, without prejudice to other lawful remedies, may defer delivery or cancel the contract for sale. If Purchaser becomes insolvent, or bankrupt or in the event any proceeding is brought against the Purchaser, voluntarily or involuntarily under the bankruptcy or any insolvency law, Square D may cancel any order outstanding at any time and recover its applicable cancellation charges from the Purchaser or the Purchaser’s estate. 8. DELIVERY: A) F.O.B. POINT OF SHIPMENT: When the Square D quotation is based on delivery F.O.B. point of shipment, freight prepaid and allowed for delivery within the continental United States, product is sold F.O.B. point of shipment, freight prepaid and allowed. A shipping and handling charge of twenty-five dollars ($25) will be added to all orders having a total net invoice price of less than one thousand dollars ($1,000). Delivery by Square D to the point of shipment constitutes delivery to the Purchaser; and title and all risk of loss or damage (Continued) Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Square D Conditions Of Sale in transit shall pass to the Purchaser at time of delivery at the F.O.B. point. Square D is not responsible for breakage after having received “in good order” receipts from the carrier. Purchaser is responsible for pursuing any damage claims with the carrier. No allowance will be made in lieu of transportation if the Purchaser accepts shipment at factory, warehouse or freight station or otherwise supplies its own transportation. Freight prepaid is defined as: a) Shipments to destinations within the continental United States to the accessible common carrier point nearest the first destination. b) Shipments to U.S. destinations outside the continental United States shall be to the common carrier free delivery point in the United States nearest the original port of embarkation. All charges associated with F.A.S., C.I.F., or other charges such as pier transfer, lift, ocean freight, and marine or war insurance shall be paid by the Purchaser, unless otherwise specifically agreed in a specific Purchase Order. In no event will Square D be responsible for demurrage or detention charges. B) DELIVERY: F.O.B. DESTINATION: When the Square D quotation is based on delivery F.O.B. Destination, for shipments for delivery within the continental United States, Square D will retain title and all risk of loss or damage in transit to the common carrier free delivery point in the United States nearest the first destination for a price addition of 2% of the net price. If the Purchaser elects this option, Purchaser’s obligations shall be as follows: a) Purchaser shall have the responsibility of inspecting the equipment for apparent loss or damage immediately upon its arrival at the free delivery point. b) In the event of apparent shipping loss or damage, Purchaser shall make written notation of the loss on the carrier’s delivery receipt and, within 72 hours of delivery shall notify the Square D Customer Information Center. Purchaser shall not remove product from the point of examination and shall retain the shipping container and packing material. Purchaser shall request the carrier to make an inspection and send Square D a copy of the carrier’s inspection report. c) In the event of concealed damage which occurred during transit and is discovered by the Purchaser after delivery, Purchaser shall report such damage immediately, but in no event later than 15 days after delivery, to the delivering carrier, and within 72 hours of discovery, shall notify the local Square D field office. If such notification is not made, Square D shall not be liable for loss or damage in transit. C) SHIPMENT AND ROUTING: Square D shall select the point of origin of shipment, the method of transportation and the routing of the shipment. Purchasers that request expedited or special modes of transportation or routing involving air, premium or any other nonstandard Square D shipping shall be assessed additional charges for shipping, handling, freight and expediting. Any rebates, allowances, discounts or incentives received by Square D from its carriers shall be retained by Square D. All prices include domestic packaging only. When other than domestic packaging is (Continued) required, contact your local Square D field office. Purchaser specified packaging and marking may be subject to additional charges. 9. SHORTAGES: Claims for shortages or errors must be made in writing to Square D within 60 days after invoice date, and failure to give such notice shall constitute unqualified acceptance and a waiver of all such claims by the Purchaser. 10. INSTALLMENTS: Square D reserves the right to make shipments in installments, unless otherwise expressly stipulated in a specific Purchase Order; and all such installments when separately invoiced shall be paid for when due per invoice without regard to subsequent shipments. Delay in shipment of any installment shall not relieve Purchaser of its obligation to accept remaining shipments. 11. FORCE MAJEURE: Square D shall not be liable for any damages as a result of any delays due to any causes beyond Square D’s control, including, without limitation, an act of God; act of Purchaser or Square D supplier; embargo or other governmental act; regulation or request; fire; accident; strike; slowdown; flood; fuel or energy shortage; sabotage; war; riot; delay in transportation and inability to obtain necessary labor, materials or manufacturing facilities from usual sources. In the event of any such delay, the date of delivery shall be extended for a period of time reasonably necessary to overcome the effect of such delay. 12. STANDARD WARRANTY: Square D warrants equipment manufactured by it and sold through authorized sales channels to be free from defects in materials and workmanship for eighteen (18) months from date of invoice by Square D or its authorized sales channel. If within such period any such equipment shall be proved to Square D’s satisfaction to be non-conforming, such equipment shall be repaired or replaced at Square D’s option. This warranty shall not apply (a) to equipment not manufactured by Square D, (b) to equipment that has been repaired or altered by other than Square D so as, in its judgment, to affect the same adversely, or (c) to equipment that has been subjected to negligence, accident, or damage by circumstances beyond Square D’s control, or improper operation, maintenance or storage, or to other than normal use or service. With respect to equipment not manufactured by Square D, the warranty obligations of Square D shall in all respects conform and be limited to the warranty actually extended to Square D by its supplier. Non-conforming products must be returned at Square D’s expense for evaluation unless this is waived in writing. Replacement products may be new or reconditioned. The foregoing warranties do not cover reimbursement for labor, transportation, removal, installation, temporary power, or any other expenses that may be incurred in connection with repair or replacement. 13. OPTIONAL WARRANTIES: (Only available on equipment to be located in the U.S.) Option 1—Extended—2 or 3 years from Shipment. If requested by the Purchaser and specifically accepted in writing by Square D, the standard © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Square D Conditions Of Sale warranty will be extended to two (2) years from date of invoice for a price addition of 1% of the net face value of the Purchase Order or will be extended for three (3) years from date of invoice for a price addition of 3% of the net face value of the Purchase Order. Option 2—Special Warranty: If requested by the Purchaser and specifically accepted in writing by Square D, the standard warranty will be extended, for a price addition of 3% of the net face value of the Purchase Order, to cover reimbursement of the direct costs of: a) Removal of non-conforming equipment or part thereof; b) Transporting equipment or parts to and from the place of repair; c) Off-loading of truck and reinstallation at the original site. Such special warranty, which may be chosen to cover a period not exceeding that of the standard or extended warranty (see above) selected, will not include the cost of providing temporary power or removing or replacing other apparatus or structures, or costs of transportation beyond a common carrier free delivery point in the continental United States. Further, the obligation of Square D for expenses and costs arising under this special warranty coverage will not exceed 50% of the net invoice price on the equipment being repaired. This warranty does not change or affect the allocation of risk or loss during shipment. Option 3—Extended Warranty—Preventative Maintenance Agreements: If requested by the Purchaser, and specifically accepted by Square D, a Preventative Maintenance Agreement is available to provide preventative maintenance on equipment covered by the agreement. Terms of the Preventative Maintenance Agreement shall be as defined in a separate Services Agreement agreed to by the parties. 14. RETURN OF EQUIPMENT: NO EQUIPMENT MAY BE RETURNED WITHOUT FIRST OBTAINING SQUARE D’S WRITTEN PERMISSION AND A RETURNED MATERIAL IDENTIFICATION TAG. Returned equipment must be of current manufacture, in the original packaging, unused, undamaged and in saleable condition. Returned equipment must be securely packed to reach Square D without damage and labeled with the return authorization number. Any cost incurred by Square D to put equipment in first class condition will be charged to the Purchaser. Purchaser requested returns not involving a Square D error will be assessed Square D's standard restocking fee. Returns will be credited at the pricing specified in Square D's standard return policy. Special Order and Custom equipment is not returnable. Square D shall bear the cost of returns resulting from Square D error, and method and route of return will be at the discretion of Square D. Costs incurred by failure to follow Square D direction will be borne by the Purchaser. 15. SOFTWARE: Any software or computer information, in whatever form that is provided with equipment manufactured by Square D, is licensed to Purchaser solely pursuant to standard licenses of Square D or its supplier of such software or computer information which licenses are hereby incorporated by reference. Square D does not warrant that such software or computer information will operate error free or without interruption, and warrants only that during the warranty period applicable to the equipment that the software will perform the essential functions © 2004 Schneider Electric All Rights Reserved 6/7/04 necessary for the normal and customary operation of the equipment. If such software or computer information fails to conform to such warranty, Square D will, at its option, provide an update to correct the non-conformance or replace the software or computer information with the latest available version containing a correction. Square D shall have no obligation to provide updates or revisions. 16. LIMITATIONS: These disclaimers and limitations of remedies apply to all warranties offered to Purchaser and to all Purchase Orders. THE WARRANTIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESSED OR IMPLIED WARRANTIES (EXCEPT WARRANTIES OF TITLE), INCLUDING, BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Except as may be expressly provided in an authorized writing by Square D, Square D shall not be subject to any other obligations or liabilities whatsoever, other than as stated above with respect to equipment sold or services rendered by Square D. Notwithstanding anything to the contrary herein contained SQUARE D COMPANY, ITS CONTRACTORS AND SUPPLIERS OF ANY TIER, SHALL NOT BE LIABLE IN CONTRACT, IN TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR OTHERWISE FOR LOST TIME, LOST PROFITS, OR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND WHATSOEVER. The remedies of the Purchaser are exclusive and the total cumulative liability of Square D, its contractors and suppliers of any tier, with respect to this contract or anything done in connection therewith, such as the use of any product covered by or furnished under the contract, whether in contract, in tort (including negligence or strict liability) or otherwise, shall not exceed the price of the product, part, or service on which such liability is based. 17. INTELLECTUAL PROPERTY: As to equipment proposed and furnished by Square D, Square D shall defend any suit or proceeding brought against Purchaser so far as based on a claim that such equipment constitutes an infringement of any copyright, trademark or patent of the United States. This obligation shall be effective only if Purchaser shall have made all payments then due hereunder and if Square D is notified promptly in writing and given authority, information, and assistance at Square D’s expense for the defense of the same. In the event the use of such equipment by Purchaser is enjoined in such a suit, Square D shall, at its expense, and at its sole option, either (a) procure for the Purchaser the right to continue using such equipment (b) modify such equipment to render it non-infringing (c) replace such equipment with noninfringing equipment, or (d) refund the purchase price (less depreciation) and the transportation and installation costs of such equipment. Square D will not be responsible for any compromise or settlement made without its written consent. The foregoing states the entire liability of Square D for patent, trademark or copyright infringement, and in no event shall Square D be liable if any infringement charge is based on the use of Square D equipment for a purpose other than that for which it was sold by Square D. As to any (Continued) Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Square D Conditions Of Sale equipment furnished by Square D to Purchaser and manufactured in accordance with designs proposed by Purchaser, the Purchaser shall indemnify Square D against any award made against Square D for patent, trademark, or copyright infringements. 18. WITNESS OF TESTS AND FACTORY INSPECTIONS: Normal production schedules do not provide the opportunity for Purchaser to witness routine factory tests on equipment or make factory inspections. Witnessing of tests or factory inspections by the Purchaser may result in delays of production for which Square D will not be responsible. Witness testing and factory inspections must be requested at time of quotation, are subject to additional costs and must be confirmed at order entry. Standard Square D factory testing and inspection will apply. Square D will notify Purchaser fourteen (14) calendar days prior to scheduled witness testing or inspection. In the event Purchaser is unable to attend, the Parties may mutually agree on a rescheduled date. However, Square D, at its sole option, may consider the witness tests and/or inspection waived, and ship and invoice the Products and the witness testing charges. Purchaser will be responsible for paying for all scheduled witness testing, whether or not Purchaser attends. 19. NUCLEAR APPLICATIONS TERMS AND CONDITIONS: Unless otherwise agreed in writing by a duly authorized representative of Square D, products sold hereunder are not intended for use in or in connection with any nuclear facility or activity. If so used, Square D disclaims all liability for any damage, injury or contamination arising from a nuclear incident or nuclear hazard; and Purchaser shall indemnify Square D against any such liability, whether arising as a result of breach of contract, warranty or tort (including negligence) or otherwise. 20. PATTERNS AND TOOLS: Notice will be given if special patterns or tools are required to complete any order. Charges for such patterns or tools do not convey title thereto or the right to remove them from Square D’s plant. If patterns or tools are not used for a period of two years, Square D shall have the right to scrap them without notice. 21. PRODUCT NOTICES: Purchaser shall promptly supply the user (including its employees) of the product with all Square D supplied product notices, warnings, instructions, recommendations and similar materials. 22. ERRORS: Square D reserves the right to correct errors or omissions in quotations, acknowledgments, invoices, or other documents. 23. OSHA COMPLIANCE: Compliance with OSHA or similar federal, state or local laws during the operation or use of the product(s) is the sole responsibility of the Purchaser. 24. TERMINATION: Any order may be terminated by the Purchaser only upon written notice to Square D and upon payment of reasonable and proper termination charges based on the price of the terminated order and reimbursement of all direct costs and expenses associated with the order caused by such termination and shall include a reasonable profit. Special or custom ordered equipment is not cancelable after final acceptance of approval drawings for the commencement of manufacturing. 25. CANCELLATION: Square D shall have the right to cancel any order or contract at any time by written notice for any material breach of the contract by the Purchaser, including material delays in releasing equipment for manufacture or approval drawings and excessive changes to specifications or drawings. © 2004 Schneider Electric All Rights Reserved 6/7/04 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz F R A C T I O N , D E C I M A L , A N D FRACTIONS TO DECIMALS TO MILLIMETERS M I L L I M E T E R E Q U I V A L E N T S C O N V E R S I O N T A B L E S MILLIMETERS TO INCHES Fractions Decimals Millimeters Millimeters Inches Millimeters Inches 1/64 1/32 3/64 1/16 0.015625 0.03125 0.046875 0.0625 0.397 0.794 1.191 1.588 5/64 3/32 7/64 1/8 0.078125 0.09375 0.109375 0.1250 1.984 2.381 2.778 3.175 0.1 0.2 0.3 0.4 0.5 0.0039 0.0079 0.0118 0.0157 0.0197 46 47 48 49 50 1.8110 1.8504 1.8898 1.9291 1.9685 9/64 5/32 11/64 3/16 0.140625 0.15625 0.171875 0.1875 3.572 3.969 4.366 4.763 0.6 0.7 0.8 0.9 0.0236 0.0276 0.0315 0.0354 51 52 53 54 55 2.0079 2.0472 2.0866 2.1260 2.1654 13/64 7/32 15/64 1/4 0.203125 0.21875 0.234375 0.2500 5.159 5.556 5.953 6.350 1 2 3 4 5 0.0394 0.0787 0.1181 0.1575 0.1969 56 57 58 59 60 2.2047 2.2441 2.2835 2.3228 2.3622 17/64 9/32 19/64 5/16 0.265625 0.28125 0.296875 0.3125 6.747 7.144 7.541 7.938 6 7 8 9 10 0.2362 0.2756 0.3150 0.3543 0.3937 61 62 63 64 65 2.4016 2.4409 2.4803 2.5197 2.5591 21/64 11/32 23/64 3/8 0.328125 0.34375 0.359375 0.3750 8.334 8.731 9.128 9.525 25/64 13/32 27/64 7/16 0.390625 0.40625 0.421875 0.4375 9.922 10.319 10.716 11.113 11 12 13 14 15 0.4331 0.4724 0.5118 0.5512 0.5906 66 67 68 69 70 2.5984 2.6378 2.6772 2.7165 2.7559 29/64 15/32 31/64 1/2 0.453125 0.46875 0.484375 0.500 11.509 11.906 12.303 12.700 16 17 18 19 20 0.6299 0.6693 0.7087 0.7480 0.7874 71 72 73 74 75 2.7953 2.8346 2.8740 2.9134 2.9528 33/64 17/32 35/64 9/16 0.515625 0.53125 0.546875 0.5625 13.097 13.494 13.891 14.288 21 22 23 24 25 0.8268 0.8661 0.9055 0.9449 0.9843 76 77 78 79 80 2.9921 3.0315 3.0709 3.1102 3.1496 37/64 19/32 39/64 5/8 0.578125 0.59375 0.609375 0.6250 14.684 15.081 15.478 15.875 41/64 21/32 43/64 11/16 0.640625 0.65625 0.671875 0.6875 16.272 16.669 17.066 17.463 26 27 28 29 30 1.0236 1.0630 1.1024 1.1417 1.1811 81 82 83 84 85 3.1890 3.2283 3.2677 3.3071 3.3465 45/64 23/32 47/64 3/4 0.703125 0.71875 0.734375 0.7500 17.859 18.256 18.653 19.050 31 32 33 34 35 1.2205 1.2598 1.2992 1.3386 1.3780 86 87 88 89 90 3.3858 3.4252 3.4646 3.5039 3.5433 49/64 25/32 51/64 13/16 0.765625 0.78125 0.796875 0.8125 19.447 19.844 20.241 20.638 36 37 38 39 40 1.4173 1.4567 1.4961 1.5354 1.5748 91 92 93 94 95 3.5827 3.6220 3.6614 3.7008 3.7402 53/64 27/32 55/64 7/8 0.828125 0.84375 0.859375 0.8750 21.034 21.431 21.828 22.225 41 42 43 44 45 1.6142 1.6535 1.6929 1.7323 1.7717 96 97 98 99 100 3.7795 3.8189 3.8583 3.8976 3.9370 57/64 29/32 59/64 15/16 0.890625 0.90625 0.921875 0.9375 22.622 23.019 23.416 23.813 61/64 31/32 63/64 1 0.953125 0.96875 0.984375 1.000 24.209 24.606 25.003 25.400 Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ 07087 USA Phone: 201-617-5800 email: sales@cuny.biz web: http://www.cuny.biz Customer I N F O R M A T I O N C E N T E R One toll-free number to call to get all the information you need. Monday-Friday 8:00 a.m. - 8:00 p.m. EST 1 - 8 8 8 - SQUARED The Square D Customer Information Center (CIC) is the single point of contact where qualified personnel answer your customer service and technical support questions. Serving all Square D authorized distributors and customers in the U.S. (1-888-778-2733) Technology W I T H O U T B O U N D A R I E S The Square D Multi-Link Structured Wiring System.... a complete network solution The Square D Multi-Link System provides a complete network solution designed to make life more mobile, more flexible, and more convenient. Providing voice, data and video connectivity throughout the home, the Multi-Link System allows you to share entertainment equipment, monitor areas of the home, and exchange data through a series of connected networks. W W W . S Q U A R E D . C O M For all of your current selection and specification information needs DigestPlus SelectorTM is the most advanced product selection tool in the industry. This intuitive, on-line selection tool will add value to your business by simplifying your design, specifying and purchasing processes. ■ Product Categories - browse by product ■ Alphabetical Listing - browse by product ■ Merchandise Product Selector - select by characteristics With access to all of the most up-to-date technical documentation and merchandise drawings to support your design and specification requirements, the Square D website is a virtual workzone. The shopping cart feature will save you time by allowing you to print to your laser printer or e-mail to your Square D distributor. Schneider Electric North American Operating Division 1415 S. Roselle Road Palatine, IL 60067 Tel: 847-397-2600 Fax: 847-925-7500 0110PL9401R5/04 (Replaces 0110PL9401R11/01) 5-04 ©2004 Schneider Electric. All rights reserved. ■ Search - by text or catalog number
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 5.0.5 for Macintosh Create Date : 2004:06:08 16:05:21Z Modify Date : 2009:01:26 11:27:24-05:00 Metadata Date : 2009:01:26 11:27:24-05:00 Creator Tool : FrameMaker 6.0: LaserWriter 8 8.7.1 Format : application/pdf Creator : Big Daniel Title : Resi 2004.fm Document ID : uuid:5155c1ef-d295-4d5f-b58e-3fe3797d0e99 Instance ID : uuid:67366f57-cd2a-4aa4-9e22-3f0482c3e00e Has XFA : No Page Count : 72 Author : Big DanielEXIF Metadata provided by EXIF.tools