Molded Case Circuit Breakers

Molded Case Circuit Breakers – Features ........................................3-2
Spectra RMS Circuit Breakers with
MicroVersaTrip Plus Trip Units – Features .....................................3-3
Molded Case Circuit Breakers – Quick Reference Guide .............3-4
Miniature Circuit Breakers and Supplementary Protectors:
Plug-in Circuit Breakers – 240V Class .............................................3-5
Bolt-on Circuit Breakers – 240V Class...........................................3-12
Bolt-on Circuit Breakers – 480/277V Class ...................................3-17
Cable-in Cable-out (lug-lug) – 240V Class ....................................3-18
DIN-Rail Mount – 240V Class ..........................................................3-21
Molded Case Switches ....................................................................3-23
E2000 Miniature Circuit Breakers
EP60 Series.........................................................................................3-24
EP100 Series.......................................................................................3-26
EP100 UC Series ...............................................................................3-28
Series CA Auxiliary Switch and Bell Alarm..................................3-30
Shunt Trip and Undervoltage Release...........................................3-32
Technical Data ...................................................................................3-33
Accessories........................................................................................3-34
Industrial Circuit Breakers—Spectra RMS, Spectra RMS with
MicroVersaTrip Plus Trip Units, Spectra RMS with MicroVersaTrip
PM Trip Units, Thermal Magnetic and J/K with MicroVersaTrip
RMS-9 and Power+ 4 Trip Units:
How to Order .........................................................................................3-37
MicroVersaTrip PM Trip Units – Features.....................................3-40
MicroVersaTrip PM Trip Unit Characteristics ..............................3-41
MicroVersaTrip PM Trip Units – How to Order ............................3-42
R-Frame Molded Case Circuit Breakers – How to Order...........3-43
Electric Trip Spectra RMS Breakers –
Quick Reference Guide ..................................................................3-44
Electric Trip Spectra RMS Breakers – IEC/JIS Ratings .............3-45
Thermal Magnetic Trip – Quick Reference Guide .......................3-46
Molded Case Circuit Breakers – Quick Reference Guide..........3-47
15-150A Circuit Breakers, Electronic Trip, Spectra RMS ...........3-48
15-150A Circuit Breakers, Thermal-Magnetic Trip, E150 Line ...3-50
70-250A Circuit Breakers, Electronic Trip, Spectra RMS ...........3-52
70-250A Circuit Breakers, Thermal-Magnetic Trip, F225 Line ...3-54
125-400A Circuit Breakers, Thermal-Magnetic Trip, Q Line ......3-55
125-600A Circuit Breakers, Electronic Trip, Spectra RMS .........3-56

60-600A Circuit Breakers, Electronic Trip, Spectra RMS ...........3-59
60-600A Circuit Breakers, Electronic Trip, Spectra RMS with
MicroVersaTrip PM Trip Units.......................................................3-59
125-600A Circuit Breakers, Thermal-Magnetic Trip,
J600 Line ...........................................................................................3-62
300-1200A Circuit Breakers, Electronic Trip, Spectra RMS .......3-64
300-1200A Circuit Breakers, Electronic Trip, Spectra RMS with
MicroVersaTrip Plus and PM ........................................................3-66
300-1200A Circuit Breakers, Thermal-Magnetic Trip,
K1200 Line.........................................................................................3-69
400-2000A Circuit Breakers, Electronic Trip – R Frame..............3-71
150-1200A Molded Case Switches, Spectra RMS.......................3-72
3-1200A, Motor Circuit Protectors, Spectra RMS .......................3-73
50-1200A, Mine Duty Circuit Breakers, Standard Duty...............3-76
Replacement Breakers, TriBreak, Internally Fused ....................3-77
Replacement Breakers, THLC Current Limiting, Unfused ..........3-79
Replacement Breakers, J and K Frame Circuit Breakers with
MicroVersa Trip Trip Units.............................................................3-80
Replacement Breakers, J and K Frame Circuit Breakers with
Power+ 4 Trip Units.........................................................................3-82
Internal Accessories
Spectra RMS Circuit Breakers .......................................................3-83
Molded Case Circuit Breakers........................................................3-85
Internally Mounted Signaling and Controlling Functions...........3-86
External Accessories
Cable Operators.................................................................................3-92
Handle Operators ..............................................................................3-93
Flange-Mounted Operators .............................................................3-94
Door-Mounted Operators.................................................................3-96
Motor Operators and Plug-in Hardware .......................................3-98
Mechanical Interlocks and Locking Devices...............................3-99
Breaker Mounting Hardware and Kits ........................................3-100
Lugs and Associated Hardware ...................................................3-101
Neutral Grounds and Sensors ......................................................3-103
Plug-in Hardware ............................................................................3-104
R Frame Accessories......................................................................3-105
Power Management System Accessories ....................................3-106
Spectra RMS Accessories – Other .................................................3-109

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-1
Prices and data subject to change without notice

MOLDED CASE
CIRCUIT BREAKERS

Section 3: Molded Case Circuit Breakers

3

Molded Case Circuit Breakers

Molded Case Circuit Breakers

es the instantaneous pickup range (with tracking short-time) but
does not change the frame ampere rating.
—Spectra RMS molded case switches have a fixed, high-set
instantaneous trip (without tracking short-time function) and have
short-circuit withstand ratings equal to their equivalent breaker
frame size interrupting rating in most cases.
—Spectra RMS breakers are ambient insensitive. Trip times will not
vary over the range 10-50°C breaker ambient. Refer to
GET-7002 for further application information.
—Spectra RMS breakers contain no parts that would support fungus
growth and are, therefore, inherently fungusproof.

Features
Spectra RMS Molded Case Circuit Breakers
SE150, SF250, SG600, and SK1200 circuit breaker frames have a
digital, solid-state, rms sensing trip system with field installable,
front-mounted rating plugs to establish or change the breaker
ampere rating. Adjustable instantaneous with tracking short-time
is standard on all frames including SE150. The trip system uses
digital sampling to determine the rms value of sinusoidal and
nonsinusoidal currents.
MicroVersaTrip Plus Trip Units or MicroVersaTrip PM Trip Units
SG600 and SK1200 are optionally available with either
MicroVersaTrip Plus or MicroVersaTrip PM trip units which offer
expanded functionality in the same space-saving size of standard
Spectra RMS breakers. The trip system uses digital sampling to
determine the rms value of sinusoidal and nonsinusoidal currents.
MicroVersaTrip Plus Trip Units

MOLDED CASE
CIRCUIT BREAKERS

MicroVersaTrip Plus trip units utilize a digital, LCD display with a
four-button keypad to provide local set-up and readout of trip settings. A 3-phase ammeter and trip indicators are standard, as is a
clear plastic cover with provisions for sealing to allow tamperresistant installation. The trip unit digitally measures the current
waveform in each phase to determine the true rms value of the
current, regardless of the waveshape.

3

MicroVersaTrip Plus trip units provide accurate, predictable overload and short-circuit protection for distribution systems that include
ac and dc variable speed drives, rectifiers, induction heating, and
other loads that cause high harmonic distortion as well as standard
circuit. They provide maximum breaker-to-breaker selectivity and
custom load protection. Short-time and ground fault functions
include the flexibility of coordination with or without an I 2t ramp.

Other MCCB Features
—UL489 Listed
—Broad product line to meet virtually any application need.
—Reduced downtime. A tripped breaker is easily spotted and can
be immediately reset after the fault has been corrected.
—Eliminates single phasing. A common trip bar disconnects all
poles simultaneously on both overloads and short circuits.
—Offers application flexibility through the use of a wide variety of
accessory devices and special attachments.
—Repetitive operation—no fuses to replace.
—Breakers can be repetitively tested. Fuses must be destroyed to
confirm calibration accuracy.
For more information on these products, order publications listed in
Sections 21 and 22.

Reference Publications
Spectra RMS Molded Case Circuit Breakers
GEH-5591
GEH-5663

MicroVersaTrip PM Trip Unit
The MicroVersaTrip PM trip unit adds power management system
capability, advanced metering, and protective relays to the basic
functions of the MicroVersaTrip Plus trip unit. The MicroVersaTrip
PM trip unit communicates directly on the GE POWER LEADER
communication bus.

GEH-5592

GEH-5934

A complete circuit breaker consists of a UL listed circuit breaker
frame and a rating plug (UL listed interchangeable trip unit).
Terminal lugs for cable connection are available if required.

GEH-5887

—All frames use the same UL listed, field-installable internal
accessories (auxiliary switch, shunt trip, undervoltage release
and bell alarm).
—All frame sizes have maximum UL listed interrupting ratings of
200 kA @ 240 Vac and 100 kA @ 480 Vac with 600 Vac ratings to 65
kA depending on frame size. UL listed current limiting versions are
provided through the SG600 frame for the 65 kA @ 480 Vac and the
100 kA @ 480 Vac models, with no increase in physical frame size.
—Spectra RMS Mag-Break instantaneous-only motor circuit protectors also use the same digital, solid-state trip unit and rating plugs
as the circuit breakers. The interchangeable rating plug establish-

GEH-5549
GEH-5551
GEH-5593
GEH-5885
DEJ-001
GEH-6250
GEH-6251
GEH-6252
GEH-6253
GEH-6254
GEH-6255
GEH-6256
GEH-6257
GEH-6258

SE150 & SF250
SG600
SG600 with MicroVersaTrip Plus and
MicroVersaTrip PM Trip Units
SK1200
SK1200 with MicroVersaTrip Plus and
MicroVersaTrip PM Trip Units
MicroVersaTrip Plus and
MicroVersaTrip PM Trip Units
in Spectra RMS Molded Case Circuit Breakers
Micro-VersaTrip Plus and
MicroVersaTrip PM Rating Plugs
Standard Rating Plugs
Shunt Trip/UV Release
Auxiliary Switch/Bell Alarm
R-Frame Molded Case Circuit Breakers
TVPBP Portable Battery Pack
Voltage Module
Power Supply Plate
Voltage Conditioner Plate
Power Supply Assembly
Voltage Conditioner Assembly
Distribution Cable Harness
Distribution Cable Extension
Distribution Cable Terminal Block
Distribution Cable Junction Box

NOTE: NEMA ABI (1975) has been superceded by UL489

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-2
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Spectra RMS Circuit Breakers with
MicroVersaTrip Plus Trip Units
Features
MicroVersaTrip Plus Trip Units
Standard
—3-phase Ammeter with ±4% accuracy.
—Adjustable Long Time (L) pickup, 0.5-1.0X, and delay (3-4 bands).
—Adjustable Instantaneous (I) pickup, 1.5-10X.
—Local Overload and Short Circuit Trip Indicators (T) with overload
pickup warning.
—Interchangeable trip ratings plugs with test set jack for
TVRMS test set.
—Digital LCD display with four-button keypad for function selection
and set point adjustment and sealable, clear Lexan cover for
tamper-resistant settings.
—True rms sensing for accurate response to high harmonic content
waveforms.
—EMI immunity per ANSI C37.90.
Optional
—Adjustable Short-Time (S) pickup, 1.0-9.0C, and delay (4 bands)
with I2t IN/OUT selection.
—Adjustable Ground fault (G) pickup, 0.2-1.0S, and delay (4 bands)
with I2t IN/OUT selection and trip indicator. The 4 short-time and
ground fault delay bands provide broader system selectivity.

SG Frame with MicroVersaTrip
Plus Trip Unit

Wide Current Setting Range—Interchangeable rating plugs
combined with 5 current sensors and 0.5-1.0X long time pickup
yield ampere ratings from 30 to 1200A.

World Standards—Frames rated to UL, CSA, IEC 947-2, and JIS.

100% Continuous Current Rated—Optionally available for 100%
UL continuous current rating applications.

Universal Internal Accessories—Uses the same front-mounted,
field installable shunt trips, undervoltage releases, bell alarms,
and auxiliary switches as standard Spectra RMS breakers.

Control Power 24 Vdc—Optionally available, provides connection
capability for +24 Vdc into the breaker via the distribution cable
system.

MOLDED CASE
CIRCUIT BREAKERS

Accessory Lead Routing Left or Right—Side channels mean no extra
space required for accessory leads.
Current Limiting—SE150, SF250 and SG600 frames rated 65kA and
100kA @ 480 Vac are UL listed as current limiting.
Reverse Feed—Front-mounted interchangeable rating plugs mean
all frames are UL listed for reverse feed.

MicroVersaTrip Plus Trip Unit Characteristics1
Current Setting (C)
(Pick-Up) (Multiple of
Rating Plug Amperes) (X)

0.5 to 1.0 in
increments of 0.05

Long-Time 2

3
Short-Time

Delay (Seconds)

3,4

2.4, 4.9, 9.8, 20

Pick-Up (Multiple of
Current Setting) (C)

1.5 to 9.0 in
increments of 0.5

Delay (Seconds)
I2 t in;4
.44
I2 t out;6
.10, .20, .30, .40

Adjustable
Instantaneous Pick-Up
(Multiple of Rating
Plug Amperes) (X)

1.5 to 10.0 in
increments of 0.5

Ground Fault
Pick-Up (Multiple of
Sensor Ampere Rating) (X)

Delay (Seconds)
I 2 t in;5
.41

.20 to 1.00 in
increments of .05

I 2 t out;6
.10, .20, .30, .40

X = Rating Plug Amperes
S = Sensor Ampere Rating
C = Long-Time Current Settings (Pick-Up)
1 Contact local GE Sales Office for use on 400 Hz applications. Not UL listed for 400 Hz.
2 Pick-up fixed at 1.1C.
3 20 second delay (band) not available on SG frames.
4 Time delay at 600% of current setting at lower limit of each band.
5Time delay at 200% of pick-up setting at lower limit of band.
6 Time delay shown at lower limit of each band. Pick-up tolerances ± 10%. Ground fault pick-up not to exceed 1200 amperes.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-3
Prices and data subject to change without notice

Molded Case Circuit Breakers

Molded Case Circuit Breakers
Quick Reference Guide
Ratings do not apply to molded case switches.
The interruption ratings and voltages shown in the table are
maximum ratings. A circuit breaker of the type given in the left-hand
column may be applied at the given circuit voltage in any electrical
distribution system where the available fault current at the load
terminals of the breaker does not exceed the value in the table.
That circuit breaker type may also be applied at intermediate values
of circuit voltage provided the available fault current at the load
terminals of the breaker does not exceed the value in the table for
the higher value of voltage.
Q Line (UL file E-11592; Fixed Thermal Magnetic Trip Unit)
Circuit
Breaker
Type
TQ

THQP

1

Ampere
Rating

No.
Poles

15-50

1

120/240

15-60

2

120/240

1

15-50

10

THHQB1
THHQC1

15-70

1

15-125

2

15-100

3

15-70

1

15-100

MOLDED CASE
CIRCUIT BREAKERS

3

15-70

1

15-125

2

15-100

3
1

TXQL1
TXQB1
TXQC1

15-30

TQDL
THQDL
TQD1
THQD1

TJD

TEY1

Vac

dc

120

—

—

—

—

Vdc

120/240

240

10

—

10

—

10

—

Dimensions (in.)

277

480

600

125

250

H

—

—

—

—

—

3

—

—

—

—

—

3 9/32

W
3/4

D

A

B

C

E

2 3/8

—

—

—

—

—
120/240
—

—

52
—

240

52

—

—

—

—

3 9/32

5
100

2 3/8

—

—

—

—

—

240

—

120/240

22

10

—

—

—

—

—

3 9/32

—
—

240

22

—

—

—

—

—

3 9/32

22
—

—
—

240

22

—

—

—

—

—

3 9/32

120/240
—

—

—

—

2

2

65

—

—

—

—

—

3 9/32

25
15
50

2 3/8

—

—

—

—

25
15
50

2 3/8

—

—

—

—

25

3

15

1

50

2

2 3/8

—

—

—

—

2

25
15

1

65
—

—

3
—

2

—

1

—
120/240

50
2 3/8

3
—

—

2

1

10
—

50

3

—
120/240

10

1/2

1
—

Std.
Pack

1 1/2

1

2
3

THHQL1

120/240

2
3

THQL1
THQB1
THQC1

ac

2
1

TQL/TQB/
TQC

UL Listed Interrupting Ratings—
rms Symmetrical kA

Maximum
Voltage Rating

50
2 3/8

—

—

—

—

240

125-200

2

120/240

—

—

10

—

—

—

—

—

—

6 1/16

2

2 3/8

—

—

—

—

12

125-200

2

120/240

—

—

22

—

—

—

—

—

—

6 1/16

2

2 3/8

—

—

—

—

12

100-225

2

240

10

10

100-225

3

240

—

10

22

22

—

22

22

22

—

22

100-225

2

240

100-225

3

240

2

240

3

240

1

277

250-400

15-100

2
3

480/277

—

—

—
125
250

—

—

—
65
—

3

25

3

—

—

—

—

6 9/16

—
2 5/8

2 7/16

2 7/16

4 1/8
—

—

—

—

—

6 9/16

2 3/4

—

—

14

14

—

65

14

—

—

10

10 1/8

8 1/4

27/32
11/16

2 7/16

2 7/16

1
1

—
2 5/8

4 1/8

27/32
11/16

1
1

3 13/16 3 15/16 3 13/16 1 3/8 1 3/16

1
1

—

—

—

2 3/4

15

14

3

—

10

—

10

10

—

—

1
5 1/4

2

3 1/16

—

—

—

—

2 3/8

—

—

—

—

—

3

CB3 Ground Fault, Equipment Ground Fault and Arc Fault (UL File E-51075; Fixed Thermal Magnetic Trip Unit)
THQB
THQC
THQL
...GF, GFEP,
AF

15-30

THHQL
...GF
THHQB
...GF, GFEP,
AF

15-30

1

120

10

—

—
2

120/240

1

120

—

1
—

—

1

22

—

—

—

—

—

—

3 9/32

10

2

—

—

—

—

—

—

3 9/32

1

10

2

3/8

—

—

—

—

10

1 UL listed as HACR (heating, air conditioning and refrigeration).
2
3

Not UL listed.
480Y/277 Vac

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-4
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Plug-in Circuit Breakers
240V Class

TQL and THQL 120/240 Vac
1
1
1
1
1
1
1
1
1
1
1

Ampere
Rating

GO-138A

120/240 Vac
Interrupting Rating

10
152
202
25
30
35
40
45
50
60
70

5kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

Wire Range1

Product Number

List Price

(1) 14-8 Cu/12-8 Al
(1) 14-8 Cu/12-8 Al
(1) 14-8 Cu/12-8 Al
(1) 14-8 Cu/12-8 Al
(1) 8-3 Cu/8-3 Al
(1) 8-3 Cu/8-3 Al
(1) 8-3 Cu/8-3 Al
(1) 8-3 Cu/8-3 Al
(1) 8-3 Cu/8-3 Al
(1) 6-1/0 Cu/4-1/0 Al

TQL1110
THQL1115
THQL1120
THQL1125
THQL1130
THQL1135
THQL1140
THQL1145
THQL1150
THQL1160
THQL1170

$20.00
$20.25
$20.25
$20.25
$20.25
$21.25
$21.25
$21.25
$21.25
$21.25
$42.50

TQL and THQL 120/240 Vac, Internal Common Trip
# of
Poles
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Ampere
Rating

120/240 Vac
Interrupting Rating

102

5kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

15
20
25
30
35
40
45
50
60
70
80
90
100
110
125

Wire Range1
(1) 14-8 Cu/12-8 Al
(1) 14-8 Cu/12-8 Al
(1) 14-8 Cu/12-8 Al
(1) 14-8 Cu/12-8 Al
(1) 8-3 Cu/8-3 Al
(1) 8-3 Cu/8-3 Al
(1) 8-3 Cu/8-3 Al
(1) 8-3 Cu/8-3 Al
(1) 8-3 Cu/8-3 Al
(1) 6-1/0 Cu/4-1/0 Al
(1) 6-1/0 Cu/4-1/0 Al
(1) 6-1/0 Cu/4-1/0 Al
(1) 6-1/0 Cu/4-1/0 Al
(1) 2-2/0 Cu/2-2/0 Al
(1) 2-2/0 Cu/2-2/0 Al

GO-138A
Product Number
TQL2110
THQL2115
THQL2120
THQL2125
THQL2130
THQL2135
THQL2140
THQL2145
THQL2150
THQL2160
THQL2170
THQL2180
THQL2190
THQL21100
THQL21110
THQL211253

THQP 120/240 Vac
# of
Poles
1
1
1
1
1
1
1
1

THQL1120

List Price
$46.00
$46.00
$46.00
$46.00
$46.00
$47.75
$47.75
$47.75
$47.75
$47.75
$95.00
$131.00
$131.00
$131.00
$284.00
$284.00

MOLDED CASE
CIRCUIT BREAKERS

# of
Poles

GO-138A

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

15
20
25
30
35
40
45
50

10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-4 Cu/8-4 Al
8-4 Cu/8-4 Al
8-4 Cu/8-4 Al
8-4 Cu/8-4 Al
8-4 Cu/8-4 Al

Product Number
THQP115
THQP120
THQP125
THQP130
THQP135
THQP140
THQP145
THQP150

List Price
$20.25
$20.25
$20.25
$20.25
$21.25
$21.25
$21.25
$21.25

3

1Solid or stranded for 14-10 AWG.
2UL listed as SWD (Switching Duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.
3Recommended for use as main or submain breaker only.
UL listed as HACR (heating, air conditioning and refrigeration).

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-5
Prices and data subject to change without notice

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Plug-in Circuit Breakers
240V Class

THQP 120/240 Vac, Internal Common Trip
# of
Poles
2
2
2
2
2
2
2
2

GO-138A

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

15
20
25
30
35
40
45
50

10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-4 Cu/8-4 Al
8-4 Cu/8-4 Al
8-4 Cu/8-4 Al
8-4 Cu/8-4 Al
8-4 Cu/8-4 Al

Product Number
THQP215
THQP220
THQP225
THQP230
THQP235
THQP240
THQP245
THQP250

List Price
$46.00
$46.00
$46.00
$46.00
$47.75
$47.75
$47.75
$47.75

15-100 ampere UL Listed as HACR (heating, air conditioning and refrigeration).

THQP230

TQL and THQL 120/240 Vac, Internal Common Trip
# of
Poles

Ampere
Rating

2
2
2
2
2
2
2
2
2
2
2
2
2
2

10
15
20
25
30
35
40
45
50
60
70
80
90
100

120/240 Vac
Interrupting Rating
5kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

GO-138

Wire Range1
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al

Product Number

List Price

TQL22010
THQL22015
THQL22020
THQL22025
THQL22030
THQL22035
THQL22040
THQL22045
THQL22050
THQL22060
THQL22070
THQL22080
THQL22090
THQL22100

$133.00
$133.00
$133.00
$133.00
$133.00
$133.00
$133.00
$133.00
$133.00
$133.00
$156.00
$221.00
$221.00
$221.00

THQL32015

MOLDED CASE
CIRCUIT BREAKERS

TQL and THQL 240 Vac, Internal Common Trip

3

# of
Poles

Ampere
Rating

3
3
3
3
3
3
3
3
3
3
3
3
3
3

10
15
20
25
30
35
40
45
50
60
70
80
90
100

240 Vac
Interrupting Rating
5kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

GO-138
Wire Range1

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al

Product Number

List Price

TQL32010
THQL32015
THQL32020
THQL32025
THQL32030
THQL32035
THQL32040
THQL32045
THQL32050
THQL32060
THQL32070
THQL32080
THQL32090
THQL32100

$165.00
$165.00
$165.00
$165.00
$165.00
$165.00
$165.00
$165.00
$165.00
$165.00
$216.00
$245.00
$245.00
$245.00

THQL and THHQL 120 Vac Arc Fault
# of
Poles
1
1
1
1

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
15
20

10kA
10kA
22kA
22kA

GO-146A
Wire Range1
14-10
14-10
14-10
14-10

Cu/14-10 Al
Cu/14-10 Al
Cu/14-10 Al
Cu/14-10 Al

Product Number

List Price

THQL1115AF
THQL1120AF
THHQL1115AF
THHQL1120AF

$170.00
$170.00
$326.00
$326.00

THQL and THHQL 120/240 Vac Arc Fault
# of
Poles
2
2
2
2

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
15
20

10kA
10kA
22kA
22kA

THQL1115AF

GO-146A
Wire Range1
14-10
14-10
14-10
14-10

Cu/14-10 Al
Cu/14-10 Al
Cu/14-10 Al
Cu/14-10 Al

Product Number

List Price

THQL2115AF
THQL2120AF
THHQL2115AF
THHQL2120AF

$385.00
$385.00
$701.00
$701.00

1Solid or stranded for 14-10 AWG.

THQL2115AF

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-6
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Plug-in Circuit Breakers
240V Class

THQL and THHQL 120 Vac, Ground Fault Circuit Interrupters
1
1
1
1
1
1

Ampere
Rating

120 Vac
Interrupting Rating

15
20
30
15
20
30

10kA
10kA
10kA
22kA
22kA
22kA

Wire Range1
14-8
14-8
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

GO-146
Product Number

List Price

THQL1115GF
THQL1120GF
THQL1130GF
THHQL1115GF
THHQL1120GF
THHQL1130GF

$159.00
$159.00
$159.00
$311.00
$311.00
$311.00

THQL and THHQL 120/240 Vac or 208Y/120 Vac,
Ground Fault Circuit Interrupters Internal Common Trip
# of
Poles
2
2
2
2
2

GO-146

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

Product Number

List Price

15
20
30
40
50

10kA
10kA
10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al

THQL2115GF1
THQL2120GF1
THQL2130GF1
THQL2140GF1
THQL2150GF1

$282.00
$282.00
$282.00
$282.00
$702.00

THQL and THHQL 120 Vac, Equipment Protection Ground Fault Circuit
Breakers Internal Common Trip
# of
Poles
1
1
1

Ampere
Rating

120 Vac
Interrupting Rating

Wire Range1

15
20
30

10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al

GO-146

Product Number

List Price

THQL1115GFEP
THQL1120GFEP
THQL1130GFEP

$271.00
$271.00
$271.00

THQL and THHQL 120/240 Vac or 208Y/120 Vac, Equipment Protection
Ground Fault Circuit Breakers
# of
Poles
2
2
2

Ampere
Rating

120/240 Vac or 208Y/120
Interrupting Rating

Wire Range1

15
20
30

10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al

GO-146

Product Number

List Price

THQL2115GFEP
THQL2120GFEP
THQL2130GFEP

$481.00
$481.00
$481.00

THQL Interlocking—for use in PowerMark Gold Generator Panels
# of
Poles
2
2

THQL1120GF

MOLDED CASE
CIRCUIT BREAKERS

# of
Poles

GO-138A

Ampere
Rating

120/240 Vac or 208Y/120
Interrupting Rating

Wire Range1

Product Number

List Price

30
60

10kA
10kA

14-8 Cu/12-8 Al
8-3 Cu/8-3 Al

THQL2130GEN
THQL2160GEN

$238.75
$238.75

3

Two breakers required for interlocking.

TQ Circuit Breakers 120/240 Vac
3/4” UL Classified Circuit Breakers for use in Square D QO Load Centers.
10 kAIC RMS symmetrical.
# of
Poles
1
1
1
1
1
2
2
2
2
2
2

GO-138Q

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

Product Number

List Price

15
20
30
40
50
15
20
30
40
50
60

10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-2 Cu/8-2 Al
8-2 Cu/8-2 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-2 Cu/8-2 Al
8-2 Cu/8-2 Al
8-2 Cu/8-2 Al

TQ1115
TQ1120
TQ1130
TQ1140
TQ1150
TQ2115
TQ2120
TQ2130
TQ2140
TQ2150
TQ2160

$20.25
$20.25
$20.25
$20.25
$20.25
$46.00
$46.00
$46.00
$46.00
$46.00
$46.00

1Solid or stranded for 14-10 AWG.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-7
Prices and data subject to change without notice

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Plug-in Circuit Breakers
240V Class

THQL and THHQL 120/240 Vac, High Intensity Discharge Lighting Loads

GO-138A

# of
Poles

List Price

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30
15
20
25
30

10kA
10kA
10kA
10kA
22kA
22kA
22kA
22kA

1
1
1
1
1
1
1
1

Wire Range1
14-8
14-8
14-8
14-8
14-8
14-8
14-8
14-8

Product Number
THQL1115HID2
THQL1120HID2
THQL1125HID
THQL1130HID
THHQL1115HID2
THHQL1120HID2
THHQL1125HID
THHQL1130HID

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

$26.00
$26.00
$26.00
$26.00
$49.50
$49.50
$49.50
$49.50

UL listed as HID.

THQL2120HID

THQL and THHQL 120/240 Vac, Internal Common Trip For High Intensity
Discharge Lighting Loads

GO-138A

# of
Poles

Product Number

List Price

THQL2115HID
THQL2120HID
THQL2125HID
THQL2130HID
THHQL2115HID
THHQL2120HID
THHQL2125HID
THHQL2130HID

$57.00
$57.00
$57.00
$57.00
$119.00
$119.00
$119.00
$119.00

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30
15
20
25
30

10kA
10kA
10kA
10kA
22kA
22kA
22kA
22kA

2
2
2
2
2
2
2
2

Wire Range1
14-8
14-8
14-8
14-8
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

UL listed as HID.

THQL 120/240 Vac, High In-Rush Loads

MOLDED CASE
CIRCUIT BREAKERS

# of
Poles

3

1
1
1
1
1
1

GO-138A

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

Product Number

List Price

15
20
25
30
40
50

10kA
10kA
10kA
10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al

THQL1115HM
THQL1120HM
THQL1125HM
THQL1130HM
THQL1140HM
THQL1150HM

$26.00
$26.00
$26.00
$26.00
$26.75
$26.75

THQL 120 Vac, For Factory Installed Shunt Trip 3,4 Internal Common Trip
# of
Poles
3

Ampere
Rating

120 Vac
Interrupting Rating

Wire Range1

20

10kA

14-8 Cu/12-8 Al

Product Number

List Price

THQL32020ST1

$273.00

THQL 120/240 Vac, Thermal Magnetic Pole plus Nonautomatic Pole
For Switching Neutral
# of
Poles
2
2
2
2
3
3
3
3

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30
15
20
25
30

10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

Wire Range1
14-8
14-8
14-8
14-8
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

GO-138

THQL1120HM

GO-138A
Product Number

List Price

THQL21WY15
THQL21WY20
THQL21WY25
THQL21WY30
THQL31WY15
THQL31WY20
THQL31WY25
THQL31WY30

$74.25
$74.25
$74.25
$74.25
$111.00
$111.00
$111.00
$111.00

1Solid or stranded for 14-10 AWG.
2UL listed as SWD (switching duty). Suitable for 120 Vac fluorescent lighting loads.
3For additional shunt trip offerings see page 3-88.
420-60 ampere are UL listed as HACR (heating, air conditioning and refrigeration).

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-8
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Plug-in Circuit Breakers
240V Class

THQMV Top-Feed Main Circuit Breaker Kits for use with 150A-225A
PowerMark Gold Load Centers

2
2
2
2
2
2

Ampere
Rating

Interrupting Rating
@ System Voltage

100
125
150
175
200
225

22kA
22kA
22kA
22kA
22kA
22kA

GO-138M

Wire Range1

Product Number

List Price

6-350
6-350
6-350
6-350
6-350
6-350

THQMV100
THQMV125
THQMV150
THQMV175
THQMV200
THQMV225

$259.00
$259.00
$259.00
$259.00
$259.00
$259.00

Cu/Al
Cu/Al
Cu/Al
Cu/Al
Cu/Al
Cu/Al

THQMV Bottom-Feed Main Circuit Breaker Kits for use with 150A-225A
PowerMark Gold Load Centers Internal Common Trip
# of
Poles
2
2
2
2
2
2

Ampere
Rating

Interrupting Rating
@ System Voltage

100
125
150
175
200
225

22kA
22kA
22kA
22kA
22kA
22kA

GO-138M

Wire Range1

Product Number

List Price

6-350
6-350
6-350
6-350
6-350
6-350

THQMV100B
THQMV125B
THQMV150B
THQMV175B
THQMV200B
THQMV225B

$259.00
$259.00
$259.00
$259.00
$259.00
$259.00

Cu/Al
Cu/Al
Cu/Al
Cu/Al
Cu/Al
Cu/Al

THLK Sub-free and Feed-through Lugs Internal Common Trip
# of
Poles
2
3
2
2
3

Ampere
Rating

Wire Range1

125
125
150
200
225

2-3/0 Cu/Al
2-3/0 Cu/Al
2-3/0 Cu/Al
6-250 Cu/Al
6-300 Cu/Al

2
2
2
2

Ampere
Rating

120/240 Vac
Interrupting Rating

125
150
175
200

10kA
10kA
10kA
10kA

THQMV200B

GO-137A
Product Number
THLK2125
THLK3125
THLK21502
THLK22002
THLK32253

TQDL 120/240 Vac, Internal Common Trip
# of
Poles

THQMV200

List Price

THLK2125

$77.00
$107.00
$137.00
$158.00
$250.00

GO-138A
Wire Range1
1/0-250
1/0-250
1/0-250
1/0-250

Cu/Al
Cu/Al
Cu/Al
Cu/Al

Product Number

List Price

TQDL21125
TQDL21150
TQDL21175
TQDL21200

$296.00
$296.00
$296.00
$296.00

THKL2150

1Solid or stranded for 14-10 AWG.

3

2For use with PowerMark Gold load centers only.
3For use with three-phase load centers only. Includes mounting base.

UL listed as HACR (heating, air conditioning and refrigeration).
Requires four one-inch spaces.

TQDL21200

THQP130

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

MOLDED CASE
CIRCUIT BREAKERS

# of
Poles

BuyLog Catalog

3-9
Prices and data subject to change without notice

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Plug-in Circuit Breakers
240V Class

THHQL 120 Vac
# of
Poles
1
1
1
1
1
1
1
1
1
1

GO-138A

Ampere
Rating

120 Vac
Interrupting Rating

Wire Range1

15
20
25
30
35
40
45
50
60
70

22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al

Product Number
THHQL11152
THHQL11202
THHQL1125
THHQL1130
THHQL1135
THHQL1140
THHQL1145
THHQL1150
THHQL1160
THHQL1170

THHQL 120/240 Vac, Internal Common Trip
# of
Poles
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

List Price
$40.25
$40.25
$40.25
$40.25
$41.25
$41.25
$41.25
$41.25
$41.25
$58.50

THHQL1120

GO-138A

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

15
20
25
30
35
40
45
50
60
70
80
90
100
110
125

22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
2-2/0 Cu/2-2/0 Al
2-2/0 Cu/2-2/0 Al

Product Number

List Price

THHQL2115
THHQL2120
THHQL2125
THHQL2130
THHQL2135
THHQL2140
THHQL2145
THHQL2150
THHQL2160
THHQL2170
THHQL2180
THHQL2190
THHQL21100
THHQL21110
THHQL21125

$93.00
$93.00
$93.00
$93.00
$97.00
$97.00
$97.00
$97.00
$97.00
$148.00
$210.00
$210.00
$210.00
$686.00
$686.00

MOLDED CASE
CIRCUIT BREAKERS

1Solid or stranded for 14-10 AWG.
2UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.
UL listed HACR (heating, air conditioning and refrigeration).

3

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-10
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Plug-in Circuit Breakers
240V Class

THHQL 240 Vac, Internal Common Trip
# of
Poles
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3

GO-138

Ampere
Rating

240 Vac
Interrupting Rating

Wire Range1

Product Number

List Price

15
20
25
30
35
40
45
50
60
70
80
90
100
15
20
25
30
35
40
45
50
60
70
80
90
100

22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al

THHQL22015
THHQL22020
THHQL22025
THHQL22030
THHQL22035
THHQL22040
THHQL22045
THHQL22050
THHQL22060
THHQL22070
THHQL22080
THHQL22090
THHQL22100
THHQL32015
THHQL32020
THHQL32025
THHQL32030
THHQL32035
THHQL32040
THHQL32045
THHQL32050
THHQL32060
THHQL32070
THHQL32080
THHQL32090
THHQL32100

$193.00
$193.00
$193.00
$193.00
$193.00
$193.00
$193.00
$193.00
$193.00
$251.00
$277.00
$277.00
$277.00
$251.00
$251.00
$251.00
$251.00
$251.00
$251.00
$251.00
$251.00
$251.00
$329.00
$359.00
$359.00
$359.00

THHQL32015

UL listed HACR (heating, air conditioning and refrigeration).

# of
Poles
2
2
2
2

Ampere
Rating

120/240 Vac
Interrupting Rating

125
150
175
200

22kA
22kA
22kA
22kA

GO-138
Wire Range1
1/0-250
1/0-250
1/0-250
1/0-250

Cu/1/0-250 Al
Cu/1/0-250 Al
Cu/1/0-250 Al
Cu/1/0-250 Al

Product Number

List Price

THQDL21125
THQDL21150
THQDL21175
THQDL21200

$713.00
$713.00
$713.00
$713.00

TXQL 120/240 Vac
# of
Poles
1
1
1
1

GO-138A

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30

65kA
65kA
65kA
65kA

Wire Range1
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

Product Number
TXQL11152
TXQL11202
TXQL1125
TXQL1130

TXQL 120/240 Vac, Internal Common Trip
# of
Poles
2
2
2
2
3
3
3
3

MOLDED CASE
CIRCUIT BREAKERS

THQDL 120/240 Vac, Internal Common Trip

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30
15
20
25
30

65kA
65kA
65kA
65kA
65kA
65kA
65kA
65kA

List Price
$74.75
$74.75
$74.75
$74.75

3

GO-138A
Wire Range1
14-8
14-8
14-8
14-8
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

Product Number

List Price

TXQL2115
TXQL2120
TXQL2125
TXQL2130
TXQL32015
TXQL32020
TXQL32025
TXQL32030

$186.00
$186.00
$186.00
$186.00
$348.00
$348.00
$348.00
$348.00

1Solid or stranded for 14-10 AWG.
2UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.

UL listed HACR (heating, air conditioning and refrigeration).

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-11
Prices and data subject to change without notice

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Bolt-on Circuit Breakers
240V Class

TQB, THQB 120/240 Vac
# of
Poles
1
1
1
1
1
1
1
1
1
1
1

GO-135B

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

10
15
20
25
30
35
40
45
50
60
70

5kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al

Product Number
TQB1110
THQB11152
THQB11202
THQB1125
THQB1130
THQB1135
THQB1140
THQB1145
THQB1150
THQB1160
THQB1170

TQB, THQB 120/240 Vac, Internal Common Trip
# of
Poles

MOLDED CASE
CIRCUIT BREAKERS

2
2
2
2
2
2
2
2
2
2
2
2
2
2

3

2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3

$19.75
$19.75
$19.75
$19.75
$19.75
$19.75
$19.75
$19.75
$19.75
$19.75
$38.00

THQB2115

GO-135B

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

10
15
20
25
30
35
40
45
50
60
70
80
90
100

5kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al

Product Number

List Price

TQB2110
THQB2115
THQB2120
THQB2125
THQB2130
THQB2135
THQB2140
THQB2145
THQB2150
THQB2160
THQB2170
THQB2180
THQB2190
THQB21100

$43.50
$43.50
$43.50
$43.50
$43.50
$43.50
$43.50
$43.50
$43.50
$43.50
$82.50
$113.00
$113.00
$113.00

TQB, THQB 240 Vac, Internal Common Trip
# of
Poles

List Price

GO-135B

Ampere
Rating

240 Vac
Interrupting Rating

Wire Range1

10
15
20
25
30
35
40
45
50
60
70
80
90
100
10
15
20
25
30
35
40
45
50
60
70
80
90
100

5kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
5kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al

Product Number

List Price

TQB22010
THQB22015
THQB22020
THQB22025
THQB22030
THQB22035
THQB22040
THQB22045
THQB22050
THQB22060
THQB22070
THQB22080
THQB22090
THQB22100
TQB320103
THQB32015
THQB32020
THQB32025
THQB32030
THQB32035
THQB32040
THQB32045
THQB32050
THQB32060
THQB32070
THQB32080
THQB32090
THQB32100

$113.00
$113.00
$113.00
$113.00
$113.00
$113.00
$113.00
$113.00
$113.00
$113.00
$148.00
$170.00
$170.00
$170.00
$139.00
$139.00
$139.00
$139.00
$139.00
$139.00
$139.00
$139.00
$139.00
$139.00
$175.00
$199.00
$199.00
$199.00

1Solid or stranded for 14-10 AWG.
2UL listed as SWD (Switching Duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.
3Not UL listed.

UL listed HACR (heating, air conditioning and refrigeration).

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-12
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Bolt-on Circuit Breakers
240V Class

THQB, THHQB 120 Vac, Ground Fault Breakers (5 ma)
# of
Poles
1
1
1
1
1
1

Ampere
Rating

120 Vac
Interrupting Rating

15
20
30
15
20
30

10kA
10kA
10kA
22kA
22kA
22kA

Wire Range1
14-8
14-8
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

GO-133
Product Number

List Price

THQB1115GF
THQB1120GF
THQB1130GF
THHQB1115GF
THHQB1120GF
THHQB1130GF

$120.00
$120.00
$120.00
$235.00
$235.00
$235.00

THQB 120/240 or 208Y/120 Vac, Ground Fault Breakers (5 ma), Internal Common Trip GO-133
# of
Poles
2
2
2

Ampere
Rating

120/240 or 208Y/120 Vac
Interrupting Rating

Wire Range1

Product Number

List Price

15
20
30

10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al

THQB2115GF
THQB2120GF
THQB2130GF

$212.00
$212.00
$212.00

THQB 120 Vac, Equipment Protection Ground Fault Circuit Breakers (30 ma)
# of
Poles
1
1
1

Ampere
Rating

120 Vac
Interrupting Rating

Wire Range1

15
20
30

10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al

GO-133

Product Number

List Price

THQB1115GFEP
THQB1120GFEP
THQB1130GFEP

$205.00
$205.00
$205.00

THQB1115GF

# of
Poles
2
2
2

Ampere
Rating

120/240 or 208Y/120 Vac
Interrupting Rating

Wire Range1

15
20
30

10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al

Product Number

List Price

THQB2115GFEP
THQB2120GFEP
THQB2130GFEP

$273.00
$273.00
$273.00

THQB 120/240 Vac, High Intensity Discharge Lighting Loads
# of
Poles
1
1
1
1

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30

10kA
10kA
10kA
10kA

Wire Range1
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

MOLDED CASE
CIRCUIT BREAKERS

THQB 120/240 or 208Y/120 Vac, Ground Fault Breakers Equipment Protection (30 ma)
Ground Fault Circuit Breakers, Internal Common Trip
GO-133

GO-135B
Product Number

List Price

THQB1115HID2
THQB1120HID2
THQB1125HID
THQB1130HID

$23.75
$23.75
$23.75
$23.75

3

UL listed as HID (high intensity discharge).

THHQB 120/240 Vac, High Intensity Discharge Lighting Loads
# of
Poles
1
1
1
1

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30

22kA
22kA
22kA
22kA

Wire Range1
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

GO-135B
Product Number
THHQB1115HID2
THHQB1120HID2
THHQB1125HID
THHQB1130HID

List Price
$41.50
$41.50
$47.00
$47.00

1Solid or stranded for 14-10 AWG.
2UL listed as SWD (switching duty). Suitable for switching 120 Vac fluorescent lighting loads.

UL listed as HID (high intensity discharge).

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-13
Prices and data subject to change without notice

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Bolt-on Circuit Breakers
240V Class

THQB 120/240 Vac, Internal Common Trip, High Intensity Discharge
Lighting Loads
# of
Poles
2
2
2
2

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30

10kA
10kA
10kA
10kA

Wire Range1
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

GO-135B
Product Number

List Price

THQB2115HID
THQB2120HID
THQB2125HID
THQB2130HID

$52.50
$52.50
$52.50
$52.50

UL listed as HID

THHQB 120/240 Vac, Internal Common Trip, High Intensity Discharge
Lighting Loads

GO-135B

# of
Poles

List Price

2
2
2
2

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30

22kA
22kA
22kA
22kA

Wire Range1
14-8
14-8
14-8
14-8

Product Number

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

THHQB2115HID
THHQB2120HID
THHQB2125HID
THHQB2130HID

$98.50
$98.50
$98.50
$98.50

UL listed as HID

THQB 120 Vac with Factory Installed 120 Vac Shunt Trip 2,3
# of
Poles
1

GO-135B

Ampere
Rating

120 Vac
Interrupting Rating

Wire Range1

Product Number

List Price

20

10kA

14-8 Cu/12-8 Al

THQB1120ST1

$113.00

THQB 120 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip 2,3 GO-135B

MOLDED CASE
CIRCUIT BREAKERS

# of
Poles

3

2
2
2
3
3
3
3
3
3
3
3
3

Ampere
Rating

120 Vac
Interrupting Rating

Wire Range1

20
30
100
20
30
40
50
60
70
80
90
100

10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
6-1/0 Cu/4-1/0 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al

Product Number

List Price

THQB2120ST1
THQB2130ST1
THQB21100ST1
THQB32020ST1
THQB32030ST1
THQB32040ST1
THQB32050ST1
THQB32060ST1
THQB32070ST1
THQB32080ST1
THQB32090ST1
THQB32100ST1

$137.00
$137.00
$205.00
$234.00
$234.00
$234.00
$234.00
$234.00
$270.00
$295.00
$295.00
$295.00

THQB 120 Vac with Switching Neutral Single Thermal Magnetic Pole;
Single Nonautomatic Pole

GO-138A

# of
Poles

Product Number

List Price

THQB21WY15
THQB21WY20
THQB21WY25
THQB21WY30

$58.50
$58.50
$58.50
$58.50

2
2
2
2

Ampere
Rating

120 Vac
Interrupting Rating

15
20
25
30

10kA
10kA
10kA
10kA

Wire Range1
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

THQB 120 Vac with Switching Neutral Two Thermal Magnetic Pole;
Single Nonautomatic Pole
# of
Poles
3
3
3
3

Ampere
Rating

120 Vac
Interrupting Rating

15
20
25
30

10kA
10kA
10kA
10kA

Wire Range1
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

GO-135B
Product Number

List Price

THQB31WY15
THQB31WY20
THQB31WY25
THQB31WY30

$88.00
$88.00
$88.00
$88.00

1Solid or stranded for 14-10 AWG.
2For additional shunt trip offerings see page 3-88.
320-60 ampere are UL listed as HACR (heating, air conditioning and refrigeration).

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-14
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Bolt-on Circuit Breakers
240V Class

THHQB 120/240 Vac
1
1
1
1
1
1
1
1
1
1

GO-135B

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

Product Number

List Price

15
20
25
30
35
40
45
50
60
70

22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al

THHQB11152
THHQB11202
THHQB1125
THHQB1130
THHQB1135
THHQB1140
THHQB1145
THHQB1150
THHQB1160
THHQB1170

$35.00
$35.00
$39.00
$39.00
$39.00
$39.00
$39.00
$39.00
$39.00
$51.00

THHQB 120/240 Vac, Internal Common Trip
# of
Poles
2
2
2
2
2
2
2
2
2
2
2
2
2

GO-135B

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

Product Number

List Price

15
20
25
30
35
40
45
50
60
70
80
90
100

22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al

THHQB2115
THHQB2120
THHQB2125
THHQB2130
THHQB2135
THHQB2140
THHQB2145
THHQB2150
THHQB2160
THHQB2170
THHQB2180
THHQB2190
THHQB21100

$82.50
$82.50
$82.50
$82.50
$82.50
$82.50
$82.50
$82.50
$82.50
$126.00
$183.00
$183.00
$183.00

THHQB 240 Vac, Internal Common Trip
# of
Poles
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3

THHQB2115

GO-135B

Ampere
Rating

240 Vac
Interrupting Rating

Wire Range1

Product Number

List Price

15
20
25
30
35
40
45
50
60
70
80
90
100
15
20
25
30
35
40
45
50
60
70
80
90
100

22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al

THHQB22015
THHQB22020
THHQB22025
THHQB22030
THHQB22035
THHQB22040
THHQB22045
THHQB22050
THHQB22060
THHQB22070
THHQB22080
THHQB22090
THHQB22100
THHQB32015
THHQB32020
THHQB32025
THHQB32030
THHQB32035
THHQB32040
THHQB32045
THHQB32050
THHQB32060
THHQB32070
THHQB32080
THHQB32090
THHQB32100

$156.00
$156.00
$156.00
$156.00
$156.00
$156.00
$156.00
$156.00
$156.00
$196.00
$235.00
$235.00
$235.00
$212.00
$212.00
$212.00
$212.00
$212.00
$212.00
$212.00
$212.00
$212.00
$263.00
$307.00
$307.00
$307.00

MOLDED CASE
CIRCUIT BREAKERS

# of
Poles

3

1Solid or stranded for 14-10 AWG.
2UL listed as SWD (switching duty). Suitable for switching 120 Vac fluorescent lighting loads.

UL listed HACR (heating, air conditioning and refrigeration).

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-15
Prices and data subject to change without notice

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Bolt-on Circuit Breakers
240V Class

TXQB 120/240 Vac
# of
Poles
1
1
1
1

GO-135B

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30

65kA
65kA
65kA
65kA

Wire Range1
14-8
14-8
14-8
14-8

Product Number
TXQB11152
TXQB11202
TXQB1125
TXQB1130

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

TXQB 120/240 Vac, Internal Common Trip
# of
Poles
2
2
2
2

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30

65kA
65kA
65kA
65kA

3
3
3
3

Ampere
Rating

240 Vac
Interrupting Rating

15
20
25
30

65kA
65kA
65kA
65kA

$63.50
$63.50
$63.50
$63.50

GO-135B
Wire Range1
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

Product Number

List Price

TXQB2115
TXQB2120
TXQB2125
TXQB2130

$154.00
$154.00
$154.00
$154.00

TXQB 240 Vac, Internal Common Trip
# of
Poles

List Price

GO-135B
Wire Range1
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

Product Number

List Price

TXQB32015
TXQB32020
TXQB32025
TXQB32030

$263.00
$263.00
$263.00
$263.00

1Solid or stranded for 14-10 AWG.
2UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.

MOLDED CASE
CIRCUIT BREAKERS

UL listed HACR (heating, air conditioning and refrigeration).

3

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-16
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Bolt-on Circuit Breakers
480Y/277V Class
The TEY is a one-inch wide per pole, compact, "bolt-on" circuit breaker for use on
grounded 480Y/277 Vac systems. The bolt-on mounting base, shown in the accessory
table on page 3-34, makes the TEY suitable for various applications as a lug-lug breaker.
TEY 1 pole
65kA @120 Vac; 14kA @120/240, 240, 277 Vac
# of
Poles
1
1
1
1
1
1
1
1
1
1
1
1
1

Ampere
Rating

Wire Range1

15
20
25
30
35
40
45
50
60
70
80
90
100

14-12 Cu/12-10 Al
14-12 Cu/12-10 Al
14-12 Cu/12-10 Al
14-10 Cu/14-10 Al
14-10 Cu/14-10 Al
14-10 Cu/14-10 Al
14-10 Cu/14-10 Al
14-10 Cu/14-10 Al
14-10 Cu/14-10 Al
4-1 Cu/2-1/0 Al
4-1 Cu/2-1/0 Al
4-1 Cu/2-1/0 Al
4-1 Cu/2-1/0 Al

GO-135B
Product Number

List Price

TEY1152,3
TEY1202,3
TEY1253
TEY1303
TEY1353
TEY1403
TEY1453
TEY1503
TEY160
TEY170
TEY180
TEY190
TEY1100

$72.00
$72.00
$72.00
$72.00
$72.00
$72.00
$72.00
$72.00
$72.00
$142.00
$142.00
$142.00
$142.00

1- 2- and 3-pole TEY breakers

TEY 2 pole
65kA @120, 120/240, 240 Vac; 14kA @277 Vac

2
2
2
2
2
2
2
2
2
2
2
2
2

Ampere
Rating

Wire Range1

15
20
25
30
35
40
45
50
60
70
80
90
100

14-12 Cu/12-10 Al
14-12 Cu/12-10 Al
14-12 Cu/12-10 Al
14-10 Cu/14-10 Al
14-12 Cu/12-10 Al
14-10 Cu/14-10 Al
14-12 Cu/12-10 Al
14-10 Cu/14-10 Al
14-10 Cu/14-10 Al
4-1 Cu/2-1/0 Al
4-1 Cu/2-1/0 Al
4-1 Cu/2-1/0 Al
4-1 Cu/2-1/0 Al

GO-135B
Product Number

List Price

TEY2153
TEY2203
TEY2253
TEY2303
TEY2353
TEY2403
TEY2453
TEY2503
TEY260
TEY270
TEY280
TEY290
TEY2100

$216.00
$216.00
$216.00
$216.00
$216.00
$216.00
$216.00
$216.00
$216.00
$352.00
$352.00
$352.00
$352.00

TEY 3 pole
65kA @120, 120/240, 240 Vac; 14kA @277 Vac
# of
Poles
3
3
3
3
3
3
3
3
3
3
3
3
3

Ampere
Rating
15
20
25
30
35
40
45
50
60
70
80
90
100

Wire Range1

MOLDED CASE
CIRCUIT BREAKERS

# of
Poles

GO-135B
Product Number

14-12 Cu/12-10 Al
14-12 Cu/12-10 Al
14-12 Cu/12-10 Al
14-10 Cu/14-10 Al
14-12 Cu/12-10 Al
14-10 Cu/14-10 Al
14-12 Cu/12-10 Al
14-10 Cu/14-10 Al
14-10 Cu/14-10 Al
4-1 Cu/2-1/0 Al
4-1 Cu/2-1/0 Al
4-1 Cu/2-1/0 Al
4-1 Cu/2-1/0 Al

3

List Price

TEY3153

$316.00
$316.00
$316.00
$316.00
$316.00
$316.00
$316.00
$316.00
$316.00
$424.00
$424.00
$424.00
$424.00

TEY3203
TEY3253
TEY3303
TEY3353
TEY3403
TEY3453
TEY3503
TEY360
TEY370
TEY380
TEY390
TEY3100

1Solid or stranded for 14-10 AWG.
2Single-pole, 15 and 20 ampere breakers are also UL listed as switching duty breakers, suitable for switching

120, 240, or 277 Vac.
3UL listed HACR (Heating, Air Conditioning, Refrigeration).

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-17
Prices and data subject to change without notice

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Cable-in Cable-out (lug-lug)
240V Class

TQC, THQC 120/240 Vac
# of
Poles
1
1
1
1
1
1
1
1
1
1
1

GO-135B

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

Product Number2

List Price

10
15
20
25
30
35
40
45
50
60
70

5kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

14-4 Cu/12-2 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al

TQC1110WL
THQC1115WL3,4
THQC1120WL3,4
THQC1125WL3
THQC1130WL3
THQC1135WL3
THQC1140WL3
THQC1145WL3
THQC1150WL3
THQC1160WL3
THQC1170WL

$20.25
$20.25
$20.25
$20.25
$20.25
$20.25
$20.25
$20.25
$20.25
$20.25
$39.00

TQC, THQC 120/240 Vac, Internal Common Trip
# of
Poles
2
2
2
2
2
2
2
2
2
2
2
2
2
2

GO-135B

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

Product Number2

List Price

10
15
20
25
30
35
40
45
50
60
70
80
90
100

5kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

14-4 Cu/12-2 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al

TQC2110WL
THQC2115WL3
THQC2120WL3
THQC2125WL3
THQC2130WL3
THQC2135WL3
THQC2140WL3
THQC2145WL3
THQC2150WL3
THQC2160WL3
THQC2170WL
THQC2180WL
THQC2190WL
THQC21100WL

$46.50
$43.50
$43.50
$43.50
$43.50
$43.50
$43.50
$43.50
$43.50
$43.50
$83.50
$116.00
$116.00
$116.00

MOLDED CASE
CIRCUIT BREAKERS

TQC, THQC 240 Vac, Internal Common Trip

3

# of
Poles
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3

GO-135B

Ampere
Rating

240 Vac
Interrupting Rating

Wire Range1

Product Number2

List Price

10
15
20
25
30
35
40
45
50
60
70
80
90
100
10
15
20
25
30
35
40
45
50
60
70
80
90
100

5kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
5kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

14-4 Cu/12-2 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
14-4 Cu/12-2 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al

TQC22010WL
THQC22015WL
THQC22020WL
THQC22025WL
THQC22030WL
THQC22035WL
THQC22040WL
THQC22045WL
THQC22050WL
THQC22060WL
THQC22070WL
THQC22080WL
THQC22090WL
THQC22100WL
TQC32010WL
THQC32015WL
THQC32020WL
THQC32025WL
THQC32030WL
THQC32035WL
THQC32040WL
THQC32045WL
THQC32050WL
THQC32060WL
THQC32070WL
THQC32080WL
THQC32090WL
THQC32100WL

$116.00
$116.00
$116.00
$116.00
$116.00
$116.00
$116.00
$116.00
$116.00
$116.00
$152.00
$173.00
$173.00
$173.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$178.00
$202.00
$202.00
$202.00

1Solid or stranded for 14-10 AWG.
2Use additional suffix “BP” (THQC32020WLBP) for bulk pack of 48 poles. Carton weight 20 lbs. 15-60 ampere breakers only.
3Suitable for mounting on standard 35mm DIN Rail. Refer to table on page 3-21 for termination options.
4UL listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.

UL listed HACR (heating, air conditioning and refrigeration). Refer to Q Line accessories listed on pages 3-34 to 3-36.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-18
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Cable-in Cable-out (lug-lug)
240V Class

THQC 120 Vac, Ground Fault Circuit Interrupter

GO-133

Ampere
Rating

120 Vac
Interrupting Rating

Wire Range1

Product Number

List Price

15
20
30

10kA
10kA
10kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al

THQC1115GF2
THQC1120GF2
THQC1130GF2

$128.00
$128.00
$128.00

1
1
1

THHQC 120/240 Vac
# of
Poles

GO-135B

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

Product Number3

List Price

15
20
25
30
35
40
45
50
60
70

22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al

THHQC1115WL4
THHQC1120WL4
THHQC1125WL4
THHQC1130WL4
THHQC1135WL4
THHQC1140WL4
THHQC1145WL4
THHQC1150WL4
THHQC1160WL4
THHQC1170WL

$35.50
$35.50
$40.50
$40.50
$40.50
$40.50
$40.50
$40.50
$40.50
$52.00

1
1
1
1
1
1
1
1
1
1

THHQC 120/240 Vac, Internal Common Trip
# of
Poles

GO-135B

Ampere
Rating

120/240 Vac
Interrupting Rating

Wire Range1

15
20
30
35
40
45
50
60
70
80
90
100

22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al

2
2
2
2
2
2
2
2
2
2
2
2

THQC1120GF

Product Number3

List Price

THHQC2115WL4
THHQC2120WL4
THHQC2130WL4
THHQC2135WL4
THHQC2140WL4
THHQC2145WL4
THHQC2150WL4
THHQC2160WL4
THHQC2170WL
THHQC2180WL
THHQC2190WL
THHQC21100WL

$83.50
$83.50
$83.50
$83.50
$83.50
$83.50
$83.50
$83.50
$129.00
$188.00
$188.00
$188.00

MOLDED CASE
CIRCUIT BREAKERS

# of
Poles

1Solid or stranded for 14-10 AWG.
2Requires mounting plate. See page 3-34. Not suitable for use in GE column panels.
3Use additional suffix “BP” (THQC32020WLBP) for bulk pack of 48 poles. Carton weight 20 lbs. 15 - 60 amperes

breakers only.
4Suitable for mounting on standard 35mm DIN Rail.

UL listed HACR (heating, air conditioning and refrigeration).
Use Q Line mounting accessories listed on pages 3-34 to 3-36.

3

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-19
Prices and data subject to change without notice

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Cable-in Cable-out (lug-lug)
240V Class
THHQC 240 Vac, Internal Common Trip
# of
Poles
2
2
2
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
3
3
3

GO-135B

Ampere
Rating

240 Vac
Interrupting Rating

Wire Range1

15
20
25
30
35
40
45
50
60
70
80
90
100
15
20
25
30
35
40
45
50
60
70
80
90
100

22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
14-8 Cu/12-8 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al
6-1/0 Cu/4-1/0 Al

Product Number

List Price

THHQC22015WL
THHQC22020WL
THHQC22025WL
THHQC22030WL
THHQC22035WL
THHQC22040WL
THHQC22045WL
THHQC22050WL
THHQC22060WL
THHQC22070WL
THHQC22080WL
THHQC22090WL
THHQC22100WL
THHQC32015WL
THHQC32020WL
THHQC32025WL
THHQC32030WL
THHQC32035WL
THHQC32040WL
THHQC32045WL
THHQC32050WL
THHQC32060WL
THHQC32070WL
THHQC32080WL
THHQC32090WL
THHQC32100WL

$159.00
$159.00
$159.00
$159.00
$159.00
$159.00
$159.00
$159.00
$159.00
$200.00
$240.00
$240.00
$240.00
$216.00
$216.00
$216.00
$216.00
$216.00
$216.00
$216.00
$216.00
$216.00
$267.00
$314.00
$314.00
$314.00

TXQC 120/240 Vac

MOLDED CASE
CIRCUIT BREAKERS

# of
Poles

3

1
1
1
1

GO-135B

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30

65kA
65kA
65kA
65kA

Wire Range1
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

Product Number

List Price

TXQC1115WL
TXQC1120WL
TXQC1125WL
TXQC1130WL

$63.50
$63.50
$63.50
$63.50

TXQC 120/240 Vac, Internal Common Trip
# of
Poles
2
2
2
2

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30

65kA
65kA
65kA
65kA

GO-135B
Wire Range1
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

Product Number

List Price

TXQC2115WL
TXQC2120WL
TXQC2125WL
TXQC2130WL

$157.00
$157.00
$157.00
$157.00

TXQC 240 Vac, Internal Common Trip
# of
Poles
3
3
3
3

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30

65kA
65kA
65kA
65kA

GO-138A
Wire Range1
14-8
14-8
14-8
14-8

Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al
Cu/12-8 Al

Product Number

List Price

TXQC32015WL
TXQC32020WL
TXQC32025WL
TXQC32030WL

$267.00
$267.00
$267.00
$267.00

1Solid or stranded for 14-10 AWG.

UL listed HACR (heating, air conditioning and refrigeration).
Use Q Line mounting accessories listed on pages 3-34 to 3-36.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-20
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
DIN-Rail Mount
240V Class
Product Features
Multi-terminal Configuration Breakers
—35 mm DIN rail mounting
—Optional front/rear panel mounting kits–THQCFMK, page 3-34.
—Optional load end terminal for up to (4) 0.25-inch quick connnects.
Contact local GE sales office for ring terminal configurations–not DIN rail compatible.
THQC, THHQC 120/240 Vac
# of
Poles
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

GO-135B

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30
35
40
45
50
60
15
20
25
30
35
40
45
50
60

10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

Product Number
THQC1115LL1
THQC1120LL1
THQC1125LL
THQC1130LL
THQC1135LL
THQC1140LL
THQC1145LL
THQC1150LL
THQC1160LL
THHQC1115LL
THHQC1120LL
THHQC1125LL
THHQC1130LL
THHQC1135LL
THHQC1140LL
THHQC1145LL
THHQC1150LL
THHQC1160LL

List Price

CC Suffix
List Price Adder

$17.25
$17.25
$17.25
$17.25
$17.25
$17.25
$17.25
$17.25
$17.25
$32.50
$32.50
$37.50
$37.50
$37.50
$37.50
$37.50
$37.50
$37.50

$4.00

X2 Suffix
List Price Adder

$1.50

15-60A UL Listed HACR (heating, air conditioning and refrigeration)

# of
Poles
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Ampere
Rating

120/240 Vac
Interrupting Rating

15
20
25
30
35
40
45
50
60
15
20
25
30
35
40
45
50
60

10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

Product Number
THQC2115LL1
THQC2120LL1
THQC2125LL
THQC2130LL
THQC2135LL
THQC2140LL
THQC2145LL
THQC2150LL
THQC2160LL
THHQC2115LL
THHQC2120LL
THHQC2125LL
THHQC2130LL
THHQC2135LL
THHQC2140LL
THHQC2145LL
THHQC2150LL
THHQC2160LL

GO-135B
List Price

CC Suffix
List Price Adder

$37.50
$37.50
$37.50
$37.50
$37.50
$37.50
$37.50
$37.50
$37.50
$77.50
$77.50
$77.50
$77.50
$77.50
$77.50
$77.50
$77.50
$77.50

$8.00

X2 Suffix
List Price Adder

MOLDED CASE
CIRCUIT BREAKERS

THQC, THHQC 120/240 Vac, Internal Common Trip

$3.00

3

15-60A UL Listed HACR (heating, air conditioning and refrigeration)

Terminal Configuration
Suffix2
WL
X2
LL
CC
None

Terminal Selection
Line Terminal
TQAL3A
TQAL3A
N/A
TQAL3A
N/A

Load Terminal
THQEL3
N/A
N/A
THQECC
THQEL3

Type
Lug–Line only
Lug–Load only
Quick Connector–Load only

GO-135B
Wire Range
14-6 Cu/12-2 Al
14-2 Cu/12-2 Al
(4) 14 Cu or (4) 12 Al

Product Number
TQAL3A
THQEL3
THQECC

List Price
$1.50
$1.50
$2.50

115 and 20 ampere breakers UL listed as SWD (Switching Duty) rated. Suitable for

switching 120 Vac fluorescent lighting loads.
2Use additional suffix “BP” (THQC1120CCBP) for bulk pack of 48 poles. Must be ordered

in multiples of 48 poles.
Additional Q Line mounting accessories listed on pages 3-34 to 3-36.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-21
Prices and data subject to change without notice

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Cable-in Cable-out (lug-lug)
240V Class

TQD 240 Vac, Internal Common Trip
# of
Poles
2
2
2
2
2
2
3
3
3
3
3
3

GO-135F

Ampere
Rating

240 Vac
Interrupting Rating

Product Number 1,2

List Price

100
125
150
175
200
225
100
125
150
175
200
225

10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA

TQD22100WL
TQD22125WL
TQD22150WL
TQD22175WL
TQD22200WL
TQD22225WL
TQD32100WL
TQD32125WL
TQD32150WL
TQD32175WL
TQD32200WL
TQD32225WL

$249.00
$249.00
$249.00
$249.00
$249.00
$249.00
$641.00
$641.00
$641.00
$641.00
$641.00
$641.00

TQD 240 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip 3

GO-135F

# of
Poles
3
3
3
3
3

Ampere
Rating

240 Vac
Interrupting Rating

Product Number 1,2

List Price

125
150
175
200
225

10kA
10kA
10kA
10kA
10kA

TQD32125ST1
TQD32150ST1
TQD32175ST1
TQD32200ST1
TQD32225ST1

$793.00
$793.00
$793.00
$793.00
$793.00

THQD 240 Vac, Internal Common Trip

MOLDED CASE
CIRCUIT BREAKERS

# of
Poles

3

2
2
2
2
2
2
3
3
3
3
3
3

GO-135F

Ampere
Rating

240 Vac
Interrupting Rating

Product Number 1,2

List Price

100
125
150
175
200
225
100
125
150
175
200
225

22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

THQD22100WL
THQD22125WL
THQD22150WL
THQD22175WL
THQD22200WL
THQD22225WL
THQD32100WL
THQD32125WL
THQD32150WL
THQD32175WL
THQD32200WL
THQD32225WL

$568.00
$568.00
$568.00
$568.00
$568.00
$568.00
$907.00
$907.00
$907.00
$907.00
$907.00
$907.00

TJD 240 Vac, Internal Common Trip
# of
Poles
2
2
2
2
3
3
3
3

GO-135F

Ampere
Rating

240 Vac
Interrupting Rating

Product Number 1,2

List Price

250
300
350
400
250
300
350
400

22kA
22kA
22kA
22kA
22kA
22kA
22kA
22kA

TJD422250WL
TJD422300WL
TJD422350WL
TJD422400WL
TJD432250WL4
TJD432300WL4
TJD432350WL4
TJD432400WL4

$1494.00
$1494.00
$1494.00
$1494.00
$1802.00
$1802.00
$1802.00
$1802.00

1Refer to table on page 3-101 for lug and wire range data.
2Includes line and load lugs. For optional configurations see page 3-38.
3For additional shunt trip options see page 3-88 .
4TJD uses same accessories as J600 line. TJD not listed HACR.

UL listed HACR (heating, air conditioning and refrigeration).

TJD432300WL

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-22
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Molded Case Switches
Note: Molded case switches may be used as main devices in panelboards and switchboards
but cannot be used as subfeeds or branch breakers because they do not provide wire
protection. Q Line and TEB molded case switches have a 10,000 ampere symmetrical short
circuit withstand rating when protected by a fuse or circuit breaker rated 10,000 amperes IC
or greater and whose ampere rating does not exceed the ampere rating of the switch.
Plug-in TQL 120/240, Vac Internal Common Trip
2
2

GO-138

Ampere
Rating

120/240 Vac
Short Circuit Withstand Rating

Wire Range1

60
100

10kA
10kA

8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al

Product Number

List Price

TQL21Y60
TQL21Y100

$51.00
$147.00

Plug-in TQL 240, Vac Internal Common Trip
# of
Poles
2
2
3
3

Ampere
Rating

240 Vac
Short Circuit Withstand Rating

60
100
60
100

10kA
10kA
10kA
10kA

GO-138
Wire Range1
8-3
6-1/0
8-3
6-1/0

Cu/8-3 Al
Cu/4-1/0 Al
Cu/8-3 Al
Cu/4-1/0 Al

Product Number

List Price

TQL22Y60
TQL22Y100
TQL32Y60
TQL32Y100

$139.00
$235.00
$177.00
$266.00

Bolt-on TQB 120/240, Vac Internal Common Trip
# of
Poles
2
2

GO-138

Ampere
Rating

120/240 Vac
Short Circuit Withstand Rating

Wire Range1

60
100

10kA
10kA

8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al

Product Number

List Price

TQB21Y60
TQB21Y100

$43.50
$113.00

Bolt-on TQB 240 Vac, Internal Common Trip
# of
Poles
2
2
3
3

Ampere
Rating

240 Vac
Short Circuit Withstand Rating

60
100
60
100

10kA
10kA
10kA
10kA

GO-138
Wire Range1
8-3
6-1/0
8-3
6-1/0

Cu/8-3 Al
Cu/4-1/0 Al
Cu/8-3 Al
Cu/4-1/0 Al

Product Number

List Price

TQB22Y60
TQB22Y100
TQB32Y60
TQB32Y100

$113.00
$170.00
$139.00
$199.00

Cable In-Cable Out (Lug-Lug) TQC 120/240 Vac, Internal Common Trip

GO-135B

# of
Poles

Product Number

List Price

TQC21Y602
TQC21Y100

$43.50
$116.00

2
2

Ampere
Rating

120/240 Vac
Short Circuit Withstand Rating

Wire Range1

60
100

10kA
10kA

8-3 Cu/8-3 Al
6-1/0 Cu/4-1/0 Al

Cable In-Cable Out (Lug-Lug) TQC 240 Vac, Internal Common Trip
# of
Poles
2
2
3
3

Ampere
Rating

240 Vac
Short Circuit Withstand Rating

60
100
60
100

10kA
10kA
10kA
10kA

Wire Range1
8-3
6-1/0
8-3
6-1/0

Cu/8-3 Al
Cu/4-1/0 Al
Cu/8-3 Al
Cu/4-1/0 Al

GO-135B
Product Number

List Price

TQC22Y603
TQC22Y100
TQB32Y60
TQB32Y100

$116.00
$173.00
$139.00
$199.00

Cable In-Cable Out (Lug-Lug) TQD, TJD 240 Vac, Internal Common Trip
# of
Poles
2
3
2
3

MOLDED CASE
CIRCUIT BREAKERS

# of
Poles

Ampere
Rating

240 Vac
Short Circuit Withstand Rating

Product Number 6

225
225
400
400

14kA
14kA
22kA
22kA

TQD22Y225
TQD32Y2254
TJD422Y400
TJD432Y4005

3

GO-135F
List Price
$198.00
$559.00
$1169.00
$1509.00

1Solid or stranded for 14-10 AWG.
2Suitable for mounting on 35 mm DIN rail.
3For additional shunt trip offerings, see page 3-88.
4TQD32YT225 with dummy trip used for accessorized applications.
5TJD uses same accessories as J600 line.
6Refer to table on page 3-101 for lug and wire range data. Line and load lugs included in basic switch product number.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-23
Prices and data subject to change without notice

Molded Case Circuit Breakers

E2000 Miniature Circuit Breakers
EP60 Series

Applications
—Residential
—Commercial
—Industrial
Performance
Thermal setting In (A)
Rated Vac Un (V)
Minimum operating voltage UB min (V)
Tripping characteristics
Selectivity class
Mechanical/electrical endurance
Tropicalisation acc. to IEC 60068-2
Terminal capacity flexible/rigid cable mm2
Poles
Weight (g/pole)

0.5-63
240/415
12
B-C-D
3
20000/10000
95% RH at 55°C
25-35
1, 2, 3, 4
120

Short-circuit Capacity
Per UL 1077 & CSA 22.2 No. 235-1989 (File E151139)
Poles
1
2
3, 4

Max. Voltage
Rating
AC
DC
277
480Y/277
480Y/277

50
110
110

120
10
10
10

Short Circuit Rating
kAIC RMS Symmetrical
120/240
277 480Y/277
–
10
10

6
6
6

–
6
6

kAIC DC
50
110
10
–
–

–
10
–

MOLDED CASE
CIRCUIT BREAKERS

AC acc. to IEC 60898

3

Poles

V

Icn/Ics (kA)

1-4

230/400

6

Poles

V

Icu (kA)1

1
2,3,4
2,3,4

240
240
415

10
20
10

Poles

V

Icu/Ics (kA)

1
2

60
125

20
25

AC acc. to IEC 60947-2

Auxiliaries

1Ics = 75% Icu

DC acc. to IEC 60947-2

Add-on Devices

Approval/Marking
—CE
—cURus
—CEBEC
—KEMA EUR

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-24
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

E2000 Miniature Circuit Breakers
EP60 Series

Poles

1

2

3

4

Std. Pack

12

6

4

3

6 kAIC In (A)
0.5
1
2
3
4
5
6
10
13
15
16
20
25
30
32
40
50
60
63
0.5
1
2
3
4
5
6
10
13
15
16
20
25
30
32
40
50
60
63
0.5
1
2
3
4
5
6
10
13
15
16
20
25
30
32
40
50
60
63
0.5
1
2
3
4
5
6
10
13
15
16
20
25
30
32
40
50
60
63

Tripping Characteristic
B (3-5X)
C (5-10X)
D (10-20X)
Product No.
Product No.
Product No.
–
–
–
–
–
EP61ULB05
EP61ULB06
EP61ULB10
EP61ULB13
EP61ULB15
EP61ULB16
EP61ULB20
EP61ULB25
EP61ULB30
EP61ULB32
EP61ULB40
EP61ULB50
EP61ULB60
EP61ULB63
–
–
–
–
–
EP62ULB05
EP62ULB06
EP62ULB10
EP62ULB13
EP62ULB15
EP62ULB16
EP62ULB20
EP62ULB25
EP62ULB30
EP62ULB32
EP62ULB40
EP62ULB50
EP62ULB60
EP62ULB63
–
–
–
–
–
EP63ULB05
EP63ULB06
EP63ULB10
EP63ULB13
EP63ULB15
EP63ULB16
EP63ULB20
EP63ULB25
EP63ULB30
EP63ULB32
EP63ULB40
EP63ULB50
EP63ULB60
EP63ULB63
–
–
–
–
–
EP64ULB05
EP64ULB06
EP64ULB10
EP64ULB13
EP64ULB15
EP64ULB16
EP64ULB20
EP64ULB25
EP64ULB30
EP64ULB32
EP64ULB40
EP64ULB50
EP64ULB60
EP64ULB63

EP61ULC0.5
EP61ULC01
EP61ULC02
EP61ULC03
EP61ULC04
EP61ULC05
EP61ULC06
EP61ULC10
EP61ULC13
EP61ULC15
EP61ULC16
EP61ULC20
EP61ULC25
EP61ULC30
EP61ULC32
EP61ULC40
EP61ULC50
EP61ULC60
EP61ULC63
EP62ULC0.5
EP62ULC01
EP62ULC02
EP62ULC03
EP62ULC04
EP62ULC05
EP62ULC06
EP62ULC10
EP62ULC13
EP62ULC15
EP62ULC16
EP62ULC20
EP62ULC25
EP62ULC30
EP62ULC32
EP62ULC40
EP62ULC50
EP62ULC60
EP62ULC63
EP63ULC0.5
EP63ULC01
EP63ULC02
EP63ULC03
EP63ULC04
EP63ULC05
EP63ULC06
EP63ULC10
EP63ULC13
EP63ULC15
EP63ULC16
EP63ULC20
EP63ULC25
EP63ULC30
EP63ULC32
EP63ULC40
EP63ULC50
EP63ULC60
EP63ULC63
EP64ULC0.5
EP64ULC01
EP64ULC02
EP64ULC03
EP64ULC04
EP64ULC05
EP64ULC06
EP64ULC10
EP64ULC13
EP64ULC15
EP64ULC16
EP64ULC20
EP64ULC25
EP64ULC30
EP64ULC32
EP64ULC40
EP64ULC50
EP64ULC60
EP64ULC63

EP61ULD0.5
EP61ULD01
EP61ULD02
EP61ULD03
EP61ULD04
EP61ULD05
EP61ULD06
EP61ULD10
EP61ULD13
EP61ULD15
EP61ULD16
EP61ULD20
EP61ULD25
EP61ULD30
EP61ULD32
EP61ULD40
EP61ULD50
EP61ULD60
EP61ULD63
EP62ULD0.5
EP62ULD01
EP62ULD02
EP62ULD03
EP62ULD04
EP62ULD05
EP62ULD06
EP62ULD10
EP62ULD13
EP62ULD15
EP62ULD16
EP62ULD20
EP62ULD25
EP62ULD30
EP62ULD32
EP62ULD40
EP62ULD50
EP62ULD60
EP62ULD63
EP63ULD0.5
EP63ULD01
EP63ULD02
EP63ULD03
EP63ULD04
EP63ULD05
EP63ULD06
EP63ULD10
EP63ULD13
EP63ULD15
EP63ULD16
EP63ULD20
EP63ULD25
EP63ULD30
EP63ULD32
EP63ULD40
EP63ULD50
EP63ULD60
EP63ULD63
EP64ULD0.5
EP64ULD01
EP64ULD02
EP64ULD03
EP64ULD04
EP64ULD05
EP64ULD06
EP64ULD10
EP64ULD13
EP64ULD15
EP64ULD16
EP64ULD20
EP64ULD25
EP64ULD30
EP64ULD32
EP64ULD40
EP64ULD50
EP64ULD60
EP64ULD63

GO-135VB
List
Price
$78.00
$65.00
$65.00
$65.00
$65.00
$65.00
$65.00
$65.00
$65.00
$65.00
$65.00
$65.00
$65.00
$65.00
$65.00
$72.00
$76.00
$80.00
$80.00
$156.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$141.00
$145.00
$156.00
$164.00
$164.00
$230.00
$204.00
$204.00
$204.00
$204.00
$204.00
$204.00
$204.00
$204.00
$204.00
$204.00
$204.00
$204.00
$204.00
$204.00
$210.00
$219.00
$229.00
$229.00
$300.00
$269.00
$269.00
$269.00
$269.00
$269.00
$269.00
$269.00
$269.00
$269.00
$269.00
$269.00
$269.00
$269.00
$269.00
$272.00
$285.00
$293.00
$293.00

1 Pole

2 Pole

MOLDED CASE
CIRCUIT BREAKERS

EP60 Series, 6 kAIC @277 or 480Y/277 Vac, Tripping Characteristics B-C-D

3 Pole

4 Pole

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-25
Prices and data subject to change without notice

3

Molded Case Circuit Breakers

E2000 Miniature Circuit Breakers
EP100 Series

Applications
—Residential
—Commercial
—Industrial
Performance
Thermal setting In (A)
Rated Vac Un (V)
Minimum operating voltage UB min (V)
Tripping characteristics
Selectivity class
Mechanical/electrical endurance
Tropicalisation acc. to IEC 60068-2
Terminal capacity flexible/rigid cable mm2
Poles
Weight (g/pole)

0.5-63
240/415
12
B-C-D
3
20000/10000
95% RH at 55°C
25-35
1, 2, 3, 4
120

Short-circuit Capacity
Per UL 1077 & CSA 22.2 No. 235-1989 (File E151139)
Poles
1
2
3, 4

Max. Voltage
Rating
AC
DC
277
480Y/277
480Y/277

50
110
110

120
10
10
10

Short Circuit Rating
kAIC RMS Symmetrical
120/240
277 480Y/277
–
10
10

10
10
10

–
–
10

kAIC DC
50
110
10
–
–

–
10
–

AC acc. to IEC 60898
Poles

V

Icn (kA)1

1-4

230/400

10

MOLDED CASE
CIRCUIT BREAKERS

1Ics = 75% Icu

3

Auxiliaries

AC acc. to IEC 60947-2
Poles

V

Icu (kA)2

1
2,3,4
2,3,4

240
240
415

15
30
15

2Ics = 50% Icu

Add-on Devices

DC acc. to IEC 60947-2
Poles

V

Icu/Ics (kA)

1
2

60
125

25
30

Approval/Marking
—CE
—cURus
—CEBEC
—KEMA EUR

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-26
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

E2000 Miniature Circuit Breakers
EP100 Series

Poles

1

2

3

4

Std. Pack

12

6

4

3

10 kAIC In (A)
0.5
1
2
3
4
5
6
10
13
15
16
20
25
30
32
40
50
60
63
0.5
1
2
3
4
5
6
10
13
15
16
20
25
30
32
40
50
60
63
0.5
1
2
3
4
5
6
10
13
15
16
20
25
30
32
40
50
60
63
0.5
1
2
3
4
5
6
10
13
15
16
20
25
30
32
40
50
60
63

Tripping Characteristic
B (3-5X)
C (5-10X)
D (10-20X)
Product No.
Product No.
Product No.
–
–
–
–
–
EP101ULB05
EP101ULB06
EP101ULB10
EP101ULB13
EP101ULB15
EP101ULB16
EP101ULB20
EP101ULB25
EP101ULB30
EP101ULB32
EP101ULB40
EP101ULB50
EP101ULB60
EP101ULB63
–
–
–
–
–
EP102ULB05
EP102ULB06
EP102ULB10
EP102ULB13
EP102ULB15
EP102ULB16
EP102ULB20
EP102ULB25
EP102ULB30
EP102ULB32
EP102ULB40
EP102ULB50
EP102ULB60
EP102ULB63
–
–
–
–
–
EP103ULB05
EP103ULB06
EP103ULB10
EP103ULB13
EP103ULB15
EP103ULB16
EP103ULB20
EP103ULB25
EP103ULB30
EP103ULB32
EP103ULB40
EP103ULB50
EP103ULB60
EP103ULB63
–
–
–
–
–
EP104ULB05
EP104ULB06
EP104ULB10
EP104ULB13
EP104ULB15
EP104ULB16
EP104ULB20
EP104ULB25
EP104ULB30
EP104ULB32
EP104ULB40
EP104ULB50
EP104ULB60
EP104ULB63

EP101ULC0.5
EP101ULC01
EP101ULC02
EP101ULC03
EP101ULC04
EP101ULC05
EP101ULC06
EP101ULC10
EP101ULC13
EP101ULC15
EP101ULC16
EP101ULC20
EP101ULC25
EP101ULC30
EP101ULC32
EP101ULC40
EP101ULC50
EP101ULC60
EP101ULC63
EP102ULC0.5
EP102ULC01
EP102ULC02
EP102ULC03
EP102ULC04
EP102ULC05
EP102ULC06
EP102ULC10
EP102ULC13
EP102ULC15
EP102ULC16
EP102ULC20
EP102ULC25
EP102ULC30
EP102ULC32
EP102ULC40
EP102ULC50
EP102ULC60
EP102ULC63
EP103ULC0.5
EP103ULC01
EP103ULC02
EP103ULC03
EP103ULC04
EP103ULC05
EP103ULC06
EP103ULC10
EP103ULC13
EP103ULC15
EP103ULC16
EP103ULC20
EP103ULC25
EP103ULC30
EP103ULC32
EP103ULC40
EP103ULC50
EP103ULC60
EP103ULC63
EP104ULC0.5
EP104ULC01
EP104ULC02
EP104ULC03
EP104ULC04
EP104ULC05
EP104ULC06
EP104ULC10
EP104ULC13
EP104ULC15
EP104ULC16
EP104ULC20
EP104ULC25
EP104ULC30
EP104ULC32
EP104ULC40
EP104ULC50
EP104ULC60
EP104ULC63

EP101ULD0.5
EP101ULD01
EP101ULD02
EP101ULD03
EP101ULD04
EP101ULD05
EP101ULD06
EP101ULD10
EP101ULD13
EP101ULD15
EP101ULD16
EP101ULD20
EP101ULD25
EP101ULD30
EP101ULD32
EP101ULD40
EP101ULD50
EP101ULD60
EP101ULD63
EP102ULD0.5
EP102ULD01
EP102ULD02
EP102ULD03
EP102ULD04
EP102ULD05
EP102ULD06
EP102ULD10
EP102ULD13
EP102ULD15
EP102ULD16
EP102ULD20
EP102ULD25
EP102ULD30
EP102ULD32
EP102ULD40
EP102ULD50
EP102ULD60
EP102ULD63
EP103ULD0.5
EP103ULD01
EP103ULD02
EP103ULD03
EP103ULD04
EP103ULD05
EP103ULD06
EP103ULD10
EP103ULD13
EP103ULD15
EP103ULD16
EP103ULD20
EP103ULD25
EP103ULD30
EP103ULD32
EP103ULD40
EP103ULD50
EP103ULD60
EP103ULD63
EP104ULD0.5
EP104ULD01
EP104ULD02
EP104ULD03
EP104ULD04
EP104ULD05
EP104ULD06
EP104ULD10
EP104ULD13
EP104ULD15
EP104ULD16
EP104ULD20
EP104ULD25
EP104ULD30
EP104ULD32
EP104ULD40
EP104ULD50
EP104ULD60
EP104ULD63

GO-135VB
List
Price
$116.00
$97.00
$97.00
$97.00
$97.00
$97.00
$97.00
$97.00
$97.00
$97.00
$97.00
$97.00
$97.00
$97.00
$97.00
$107.00
$113.00
$119.00
$119.00
$233.00
$210.00
$210.00
$210.00
$210.00
$210.00
$210.00
$210.00
$210.00
$210.00
$210.00
$210.00
$210.00
$210.00
$210.00
$216.00
$233.00
$245.00
$245.00
$343.00
$304.00
$304.00
$304.00
$304.00
$304.00
$304.00
$304.00
$304.00
$304.00
$304.00
$304.00
$304.00
$304.00
$304.00
$314.00
$327.00
$342.00
$342.00
$448.00
$401.00
$401.00
$401.00
$401.00
$401.00
$401.00
$401.00
$401.00
$401.00
$401.00
$401.00
$401.00
$401.00
$401.00
$407.00
$425.00
$437.00
$437.00

1 Pole

2 Pole

MOLDED CASE
CIRCUIT BREAKERS

EP100 Series, 10 kAIC @120 or 120/240 Vac, Tripping Characteristics B-C-D

3 Pole

4 Pole

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-27
Prices and data subject to change without notice

3

Molded Case Circuit Breakers

E2000 Miniature Circuit Breakers
EP100 UC Series1

Applications
—Industrial
Performance
Thermal setting In (A)
Rated Vac Un (V)
Minimum operating voltage UB min (V)
Tripping characteristics
Selectivity class
Mechanical/electrical endurance
Tropicalisation acc. to IEC 60068-2
Terminal capacity flexible/rigid cable mm2
Poles
Weight (g/pole)

0.5-63
240/400; 230/440
12
B-C
3
20000/10000
95% RH at 55°C
25-35
1, 2
120

Short-circuit Capacity
AC acc. to IEC 60898
Poles

V

Icn/Ics (kA)

125 DC
220 DC
230/400 AC
250 DC
440 DC
400 AC

10
6
6
10
6
6

Poles

V

Icu/Ics (kA)

1, 2

240 AC

10

1

2

MOLDED CASE
CIRCUIT BREAKERS

AC acc. to IEC 60947-2

Approval/Marking
—IEC 60898-2, DIN VDE 0641
—CE

Auxiliaries

1Not UL approved

Add-on Devices

3

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-28
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

E2000 Miniature Circuit Breakers
EP100 UC Series1

EP100 UC Series, 10 kAIC @125 Vdc, 1 Pole, Tripping Characteristics B-C
Poles

Std. Pack

1

2

12

6

6 kAIC In (A)
0.5
1
2
4
6
10
16
20
25
32
40
50
63
0.5
1
2
4
6
10
16
20
25
32
40
50
63

GO-135VB

Tripping Characteristic
B (3-5X)
C (5-10X)
Product No.
Product No.
–
–
–
–
EP101UCB06
EP101UCB10
EP101UCB16
EP101UCB20
EP101UCB25
EP101UCB32
EP101UCB40
EP101UCB50
EP101UCB63
–
–
–
–
EP102UCB06
EP102UCB10
EP102UCB16
EP102UCB20
EP102UCB25
EP102UCB32
EP102UCB40
EP102UCB50
EP102UCB63

List
Price

EP101UCC0.5
EP101UCC01
EP101UCC02
EP101UCC04
EP101UCC06
EP101UCC10
EP101UCC16
EP101UCC20
EP101UCC25
EP101UCC32
EP101UCC40
EP101UCC50
EP101UCC63
EP102UCC0.5
EP102UCC01
EP102UCC02
EP102UCC04
EP102UCC06
EP102UCC10
EP102UCC16
EP102UCC20
EP102UCC25
EP102UCC32
EP102UCC40
EP102UCC50
EP102UCC63

$145.00
$121.00
$121.00
$121.00
$121.00
$121.00
$121.00
$121.00
$121.00
$121.00
$121.00
$145.00
$163.00
$320.00
$267.00
$267.00
$267.00
$267.00
$267.00
$267.00
$267.00
$267.00
$267.00
$267.00
$319.00
$360.00

1 Pole

1Not UL approved

MOLDED CASE
CIRCUIT BREAKERS

2 Pole

3

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-29
Prices and data subject to change without notice

Molded Case Circuit Breakers

E2000 Miniature Circuit Breakers
Series CA Auxiliary Switch and Bell Alarm
Applications
—Commercial
—Industrial

Features
—Common for all MCBs
—Can be coupled on both sides of MCBs
—Gold contact version available for low current and low voltage
applications
—Stack up to four CA on left and right sides
—Permits the pass-through of busbars, pin and fork, top and bottom,
by changing the position of the base of the auxiliaries

Performance
Change-over contacts
Rate current In (A)
Rated voltage AC Un (V)
Electrical endurance
Terminal capacity flexible/rigid cable (mm2)
Weight (g)

1 Form C
5
240
10000
2.5
70

Functions
Auxiliary contacts are units to be added on to protection devices.
They allow information about the status of the protection device to
be monitored from a distance.

Coupling

MOLDED CASE
CIRCUIT BREAKERS

Auxiliary contact CA H (function H) reports the OPEN/CLOSED status.

3

CA S/H or CA S/H G act as either an auxiliary contact (function H) or
a signal contact (function S). The user can set the function at the
time of installation. When used as a signal contact, it reports information about the automatic tripping of the protection devices. A test
button on the front simulates functions H or S. There are also a reset
button for the contacts (function S) and a tripping signal (function S).

Busbar pass-through

Approval/Marking
—CE
—cURus
—CEBEC
—KEMA EUR

Stack-on

Series CA

GO-135VB

Function

Std. Pack

Product No.

List Price

H
S/H
S/H (gold contacts)

1
1
1

CA H
CA S/H
CA S/H G

$47.00
$59.00
$59.00

1/2 mod.

H

S

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-30
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

E2000 Miniature Circuit Breakers
Series CB Auxiliary Switch and Bell Alarm
Applications
—Commercial
—Industrial

Features
—Common for all MCBs
—Can be coupled on both sides of MCBs
—There are two change-over contacts – the upper one features
changeable function S/H
—CB SH/HH-R couples to the right side of the protection devices;
CB SH/HH-L couple to the left
—No stack-on possibilities (only one auxiliary)
—No busbar pass-through facilities

Performance
Change-over contacts
Rate current In (A)
Rated voltage AC Un (V)
Electrical endurance
Terminal capacity flexible/rigid cable (mm2)
Weight (g)

2 Form C
5
240
10000
2.5
80

Functions

The top auxiliary contact can act as either an auxiliary contact
(function H) or a signal contact (function S). The user can set the
function at the time of installation. When used as a signal contact,
it reports information about the automatic tripping of the protection
devices.
A test button on the front simulates functions H or S. There are also
a reset button for the contacts (function S) and a tripping signal
(function S).

MOLDED CASE
CIRCUIT BREAKERS

The bottom auxiliary contact (function H) reports the OPEN/CLOSED
status.

Coupling right

3

Approval/Marking
—cURus
Coupling left

Series CB

GO-135VB

Function

Coupling

Std. Pack

Product No.

List Price

SH/HH
SH/HH

Right
Left

1
1

CB SH/HH-R
CB SH/HH-R

$87.00
$87.00

1/2 mod.

H

S

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-31
Prices and data subject to change without notice

Molded Case Circuit Breakers

E2000 Miniature Circuit Breakers
Shunt Trip and Undervoltage Release
Applications
—Commercial
—Industrial
Features
—Common devices for all miniature circuit breakers
—Can be coupled on both sides of MCBs
—Permits pass-through of busbars, pin and fork, at top or
bottom terminals
—Stack up to four modules on left and right sides
Approval/Marking
—cURus
—IEC 947-2

Shunt Trip Tele L
The Tele L allows remote switching of any miniature circuit breaker
by means of push buttons or any other automatic management
processor. A built-in contact, in series with the coil, prevents burnout
damage if the voltage remains.
Shunt Trip Tele L Performance

MOLDED CASE
CIRCUIT BREAKERS

Rated voltage (V)
(V)
Tripping time (ms)
Electrical endurance
Terminal capacity flexible/rigid cable (mm2)
Weight (g)

3

110/415, 110/125 DC
24/60, 24/48 DC
<10
10000
2.5
125

Shunt Trip Tele L

Coupling

GO-135VB
Voltage

Poles
1

Std. Pack

AC

DC

Product No.

List Price

1

24-60 V
110-415 V

24-48 V
110-125 V

TELE L-1
TELE L-2

$90.00
$90.00

Busbar pass-through

Undervoltage Release Tele U
The Tele U releases the main miniature circuit breaker in case the
power supply drops below 0.5xUn. Time delay is adjustable up to 300 ms.

Stack-on

Undervoltage Release Tele U Performance
Rated voltage AC UN (V)
Rated voltage DC/AC UN (V)
Tripping voltage (V)
Resetting voltage (V)
Tripping time (ms)
Electrical endurance
Terminal capacity flexible/rigid cable (mm2)
Weight (g)

240
12, 24, 48 DC/AC
≤0.5xUN ±10%
>0.5xUN ±10%
Adjustable 1-300
2000
2.5
125

Undervoltage Release Tele U
Poles

1

Std. Pack

Voltage

1

AC 230V
AC/DC 12V
AC/DC 24V
AC/DC 48V

GO-135VB
Product No.
TELE
TELE
TELE
TELE

U-230
U-12
U-24
U-48

List Price
$128.00
$128.00
$128.00
$128.00

Shunt Trip Tele L

Undervoltage Release Tele L

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-32
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

E2000 Miniature Circuit Breakers
Technical Data

Standards
Tripping characteristics
Nominal current
Calibration temperature
Number of poles (# mod)
Neutral pole protected
Nominal voltage Un

EP100

EP100 UC

°C/RH
°C
°C
mm2
mm2

UL1077, EN60947-2
B, C, D
B: 6-63, C/D: 0.5-63
30
1/1+N/2/3/4
yes
240/415
415
415
48
110
50/60
DC:magn.trip + 40%
DC:magn.trip + 50%
250/440; 53/120
12; 12
3
yes
500
440
6
10000
2.5
3g
10000
20000
A
any
yes
IP20/IP40
V2
+55%°C/95% RH
-25/+55
-55/+55
1/35
0.75/25

UL1077, EN60947-2
B, C, D
B: 6-63, C/D: 0.5-63
30
1/1+N/2/3/4
yes
240/415
415
415
48
110
50/60
DC:magn.trip + 40%
400:magn.trip + 50%
250/440; 53/120
12; 12
3
yes
500
440
6
10000
2.5
3g
10000
20000
A
any
yes
IP20/IP40
V2
+55%°C/95% RH
-25/+55
-55/+55
1/35
0.75/25

IEC EN70898-2
B, C
B: 6-63, C: 0.5-63
30
1/2
–
240/415
415
415
220
440
50/60
DC:magn.trip + 40%
400:magn.trip + 50%
250/440; 250/440
12; 12
3
yes
500
440
6
10000
2.5
3g
1000
20000
A
any
yes
IP20/IP40
V2
+55%°C/95% RH
-25/+55
-55/+55
1/35
0.75/25

mm2
mm2

1/35
0.75/25

1/35
0.75/25

1/35
0.75/25

Nm

4.5
yes
yes
yes
yes/yes
-/yes
yes
18
120
12
KEMA
yes

4.5
yes
yes
yes
yes/yes
-/yes
yes
18
120
12
KEMA
yes

4.5
yes
yes
yes
yes/yes
-/yes
yes
18
125
12
yes

A
°C

AC

DC

1P
2P
3P/3P+N/4P
1P (1)
2P (in series) (1)

Frequency

Maximum service voltage Ubmax between two wires
Minimum service voltage Ubmin
Selectivity class (IEC 60898)
Isolator application IEC 60947-2
Rated insulation voltage – Pollution Degree 2
Rated insulation voltage – Pollution Degree 3
Impulse withstand test voltage
Insulation resistance
Dielectric rigidity
Vibrations resistance (in x,y,z direction) (IEC 77/16,3)
Endurance – electrical at Un, In
Endurance – mechanical
Utilization category (IEC 60947 - 2)
Mounting position
Incoming top or bottom
Protection degree (outside/inside enclosure with door)
Self extinguish degree (according to UL94)
Tropicalisation (according to IEC 60068-2/DIN 40046)
Operating temperature
Storage temperature
Terminal capacity – Rigid cable min/max (top)
Terminal capacity – Flexible cable min*/max (top)
(*Flexible cable 0.75/1/1.5 mm2 with cable lug)
Terminal capacity – Rigid cable min/max (bottom)
Terminal Capacity – Flexible cable min*/max (bottom)
(*Flexible cable 0.75/1/1.5 mm2 with cable lug)
Torque
Add-on services – Auxiliary contacts
Add-on services – Tele U
Add-on services – Tele L
Busbar systems – pin (top/bottom) (non-UL)
Busbar systems – fork (top/bottom) (non-UL)
Accessories
Dimensions, weights, packaging

V
V
V
Vdc
Vdc
Hz
Hz
Hz
V
V

V
V
Kv
Mohm
Kv

(HxDxW) 86x68xW
Weight/mod
Package

mm/mod
g
mod.

Approvals
CE-marking

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-33
Prices and data subject to change without notice

MOLDED CASE
CIRCUIT BREAKERS

Series
EP60

3

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Accessories

Terminals (Lugs) for Q Line Circuit Breakers
Ampere Rating
15-60
15-60
15-60

GO-135B

Termination Type

Wire Range (Cu/Al)

Lug (line only)
Lug (load only)
Quick connector (load only)

14-6/12-2
14-2/12-2
(4) 14/(4) 12

Product Number

List Price

TQAL3A
THQEL3
THQECC

$1.50
$1.50
$2.50

Internal Accessories for TEY (2- and 3-pole breaker only)
Factory Installed Only
Auxiliary Switch,
Single-Pole
(6A at 240 Vac,1/2A at 125 Vdc, 1/4A at 250 Vdc)

GO-135B

Add suffix to Breaker
Product Number

List Price Adder

AS1A
AS1B
ASAB
ST12

$148.00
$148.00
$288.00
$358.00

"A" switch (normally open)
"B" switch (normally closed)
"AB" switch (both)
Shunt Trip 120-277 Vac control voltage

Mounting Accessories for THQB, THQC, TEY

MOLDED CASE
CIRCUIT BREAKERS

Product
Type

Ampere
Rating

GO-135B

# of
Poles

Used With
Frame

Bolt-on Mounting Base

3

Back Mounting Plates
Screw Type
Back Mounting Plates
Screw Type
Back Mounting Plates
Screw Type
Back Mounting Plates
Screw Type
Front-mounting Plates
Front-mounting Plates
Front-mounting Plates
Front-mounting Plates
Front/Rear Mounting
Clips
DIN rail clips

1

TEY
THQB
THQC

TQCBMPA1

$8.30

2

THQC

TQCBMPA2

$9.80

3

THQC

TQCBMPA3

$12.00

10

THQC

TQCBMPA10

$32.00

15-60A

1
2
3
4
1&2

THQC
THQC
THQC
THQC
THQC

TQCFMP11
TQCFMP21
TQCFMP31
TQCFMP41
THQCFMK2

$8.30
$9.80
$12.00
$14.00
$48.00

15-60A

1&2

THQC

THQCDIN2

$24.00

Product Number
TEY3B

List
Price
$31.50

Load Lug THQEL3

1Not UL listed.
2Price is per pack.

Mounting Accessories for THQC, THQC-GF, GFEP, AF

3

Quick Connector THQECC

Product Type

GO-133

# of Poles

Used With Frame

Product Number

List Price

1

THQC, THQC-GF

TQCGFBMPA1

$6.10

2

THQC, THQC-GF

TQCGFBMPA2

$7.60

3

THQC, THQC-GF

TQCGFBMPA3

$9.10

10

THQC, THQC-GF

TQCGFBMPA10

$25.00

Snap In Back
Mounting Plates
Snap In Back
Mounting Plates
Snap In Back
Mounting Plates
Snap In Back
Mounting Plates

Mounting Accessories for TQL
Product
Type
Plug-in
Plug-in
Plug-in
Plug-in

Mounting
Mounting
Mounting
Mounting

Base
Base
Base
Base

Mounting Kit THQCFMK

G0-134A

Ampere
Rating

# of
Poles

Used With
Frame

Product Number

List
Price

70 amp
70 amp
100 amp
100 amp

2
3
3
2

TQL
TQL
TQL
TQL

571B595DDG1
571B595DDG2
565B837G1
565B837G2

$23.75
$32.00
$38.00
$23.75

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-34
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Accessories

Handle Locking Devices
Product Number

List Price

THL103

$6.501

TQPL

$5.501

TEYLD1

$5.00

E150 Line

TLD3

$5.00

THLC2, 4
F225 Line
SF250
SE150

TFKLD1

$6.00

SBD1

$4.702

Handle Locks Non Padlocking
Handle Locks Non Padlocking
Handle Locks Non Padlocking
Handle Locks Non Padlocking
Handle Locks Non Padlocking
Handle Locks Non Padlocking

GO-135B

Used With Frame
TQC
TQB
TQL
THQP
TEY

Handle Locking Devices
Product Type

GO-137A

Used With Frame

Handle Locks - Padlocking
Handle Locks - Padlocking
Handle Locks - Padlocking

TQD
TQDL
TQB
TQL
THQP

Handle Locks - Padlocking

Product Number

List Price

TQDPLD13
TQDLPDL13
THP100

$20.75
$17.75
$6.501

TQPPL

$5.75

Handle Locking Devices
Product Type
Handle Locks - Padlocking
Handle Locks - Padlocking
Handle Locks - Padlocking
Handle Locks - Padlocking
Handle Locks - Padlocking
Handle Locks - Padlocking

Handle Locks - Padlocking
Handle Locks - Padlocking

GO-135B

Used With Frame

Product Number

TQC
TEY
E150
TB1
THLC1
F225
THLC2
THLC4
TLB4
J600 Line
K1200 Line

List Price

TQPLD13
TEYPLD1
TEFPLD1

$4.70
$9.00
$8.00

TLC1PLD1
TFKPLD1
TLC4PLD1

$17.00
$4.00
$22.00

TJKPLD1
TKMPLD1

$8.00
$28.50

Product Number

List Price

Handle Locking Devices
Product Type
Handle Locks - Padlocking
Handle Locks - Padlocking
Handle Locks - Padlocking

THL103

THP100

MOLDED CASE
CIRCUIT BREAKERS

Product Type

GO-135S

Used With Frame
SF250
SE150
SG600
SK1200

SEPLD3

$8.70

SGPLD3
SKPLD3

$15.00
$28.50

3

1GO-137A.
2GO-135S.
3Suitable for circuit breakers used in group mounted panelboard construction only except for J600, K1200, SE150/SE250,

SG600 and SK1200 which screw down to face of breaker.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-35
Prices and data subject to change without notice

Molded Case Circuit Breakers

Miniature Circuit Breakers and Supplementary Protectors
Accessories

Handle Locking and Handle Extension Devices EUSERC Approved —
Factory Installed Only
Product Type
Handle
Handle
Handle
Handle
Handle
Handle
Handle
Handle

Locks
Locks
Locks
Locks
Locks
Locks
Locks
Locks

Used With Frame
-

Padlocking
Padlocking
Padlocking
Padlocking
Padlocking
Padlocking
Padlocking
Padlocking

Product Number

GO-135B
List Price

TQDPLD2
TEDPLD2
TJKPLD2
THLC1PLD2
THLC4PLD2
SEFPLD2
SGPLD2
SKPLD2

$32.00
$32.00
$48.00
$48.00
$48.00
$32.001,2
$48.001
$60.001

THT1

Handle Locking and Handle Extension Devices
Product Type

Used With Frame

Snap-on Handle Tie - open
Snap-on Handle Tie - solid
Snap-on Handle Tie - solid,
indicating
Snap-on Handle Tie - trip
indicating
Handle Extension - replacement

GO-137A
Product Number

List Price

THQP
TQL
THQP

THT23
THT104
THT1

$2.30
$2.30
$2.30

TQC

TQHT1

$2.30

SK1200

SKHDLEXT

Used With Frame

Product Number

$96.501

Breaker Mounting Screw Kits
Product Type
Breaker Mounting Screw Kits

GO-135B
THQB

List Price

TQBS14

$6.00

1GO-135S.

THT104

2Field Installable
3For 2 THQPs separated by 2 side-by-side THQPs.

MOLDED CASE
CIRCUIT BREAKERS

4Price is per screw. Packaged in quantities of 24. Must be ordered in multiples of 24.

3

TQHT1

THT2

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-36
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
Spectra RMS, Spectra RMS with MicroVersaTrip Plus Trip Units, Spectra RMS
with MicroVersaTrip PM Trip Units, Thermal Magnetic and J/K with MicroVersaTrip RMS-9
and Power+ 4 Trip Units

—Mag-Break Motor Circuit Protectors
Determine the required frame and ampere requirements.
Select frame, trip unit (rating plug), and lug, if required,
product numbers from the table on pages 3-73 through 3-75.
Select accessories as noted above for circuit breakers. The
same accessories are used with both circuit breakers and
motor circuit protectors. Order as separate items.
—Molded Case Switches
Determine the required frame and ampere requirements.
Select frame and lug, if required, product numbers from
the table on page 3-72. Rating plugs are not used. Select
accessories as noted above for circuit breakers. Internal
accessories do not require dummy trips. The same accessories
are used with both circuit breakers and molded case switches.
Order as separate items.
Unless otherwise noted, all circuit breakers are UL listed in File
E–11592. Molded case switches are UL listed in File E–57546.
Field-Installable Internal Accessories are UL listed in File E–57253.
Distribution Cable Accessories for MicroVersaTrip Plus Trip Units
and MicroVersaTrip PM Trip Units are UL listed in File E–57253.
E 150 Line
—Thermal Magnetic Circuit Breakers
—Magnetic Circuit Breakers
—Molded Case Switches
The product numbers as shown in the following pages include the
complete breaker or switch. All devices listed come with Cu/Al line
and load lugs. If line lugs are not required on a breaker, eliminate
“WL” from product number; for molded case switches see page
3-38. Unless otherwise noted, all circuit breakers are UL listed in
File E–11592. Molded case switches are UL listed in File E–57546.
F 225 Line
—Thermal Magnetic Circuit Breakers
—Magnetic Circuit Breakers
—Molded Case Switches
These breakers are available with either noninterchangeable trips
(designated Type TFJ) or interchangeable trips (designated Types
TFK/THFK). When ordering Type TFJ, product number includes
complete breaker, trip unit, CU/Al line and load lugs factory

assembled. If line lugs are not required on a breaker, eliminate “WL”
from product number, and subtract price of line lugs from price of
complete breaker. If interchangeable trip (Types TFK/THFK) is
required order one of two ways. “Complete circuit breaker” price
includes frame, trip, Cu/Al line and load lugs. Units will be shipped
unassembled unless specified on order “must be factory assembled.”
If line lugs are not required on a breaker, eliminate “WL” from
product number, and subtract price of line lugs from price of complete breaker. To order the frame, trip, and lugs separately, select the
required components from table. Magnetic breakers must be ordered
as components. A complete breaker consists of frame, trip unit, one
line lug per pole and one load lug per pole. Price of “Complete Circuit
Breaker” vs. ordering frame, trip, and line and load lugs separately
is the same.
Molded case switches can also be ordered as complete units
(designated TFK---Y) or as separate components. They are UL listed
only as complete units. To indicate required lugs, see page 3-38.
Unless otherwise noted, all circuit breakers are UL listed in File
E–11592. Molded case switches are UL listed in File E–57546.
J 600 Line
—Thermal Magnetic Circuit Breakers
—Magnetic Circuit Breakers
—Molded Case Switches
These breakers are available with either noninterchangeable trip
(designated Type TJJ) or interchangeable trip (designated Type TJK
and THJK). Type TJJ product numbers include frame, trip, Cu/Al line,
and load lugs factory assembled. If line lugs are not required on the
breaker, eliminate “WL” from product number, and subtract price of
line lugs from price of complete breaker.
TJK breakers are available in two frames, 400 ampere frame (125 to
400 amperes) and 600 ampere frame (250 to 600 amperes). Trip units
are not interchangeable between frames.
“Complete Circuit Breaker” price includes frame, trip unit, Cu/Al
line, and load lugs. Unit will be shipped unassembled unless order
specifies “must be factory assembled.” If line lugs are not required,
eliminate “WL” from product number and subtract price of line lugs
from price of complete breaker.
To order the frame, trip, and lugs separately, select the required
components from table. Magnetic breakers must be ordered as
components. A complete breaker consists of frame, trip, and one
line and one load lug per pole.
Price of ordering “Complete Circuit Breaker” vs. frame, trip, and
line and load lugs separately is the same.
Molded case switches can also be ordered as complete units
(designated Type TJK---Y) or as separate components. They are UL
listed only as complete units. To indicate required lugs, see
page 3-38.
Unless otherwise noted, all circuit breakers are UL listed in File
E–11592. Molded case switches are UL listed in File E–57546.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-37
Prices and data subject to change without notice

MOLDED CASE
CIRCUIT BREAKERS

How to Order
Spectra RMS
—Circuit Breakers
Determine the required breaker frame, IC rating, and load
requirements. Select frame, trip unit (rating plug), and lug, if
required, product numbers from the tables on pages 3-48 to
3-58. For Spectra breakers with MicroVersaTrip Plus Trip Units
or MicroVersaTrip PM Trip Units refer to pages 3-59 through
3-61. Select field-mounted internal accessory product
numbers, if required, on pages 3-83 and 3-84. Select fieldmounted external accessory product numbers, if required, on
pages 3-92 through 3-104. Order as separate items.

3

Molded Case Circuit Breakers

Industrial Case Circuit Breakers

K 1200 Line

Mag-Break Line
—Magnetic only circuit breakers (motor circuit protectors)

—Thermal Magnetic Circuit Breakers
—Magnetic Breakers
—Molded Case Switches

These breakers are available only with noninterchangeable
adjustable magnetic trip, in frame Types E, F, J, K, and Tri-Break.
All breakers are shipped factory assembled, complete with Cu/Al line
and load lugs.

These breakers are available only with interchangeable trip units.
Two frame sizes are available, the 800 ampere frame (300 to 800
amperes) and the 1200 ampere frame (600 to 1200 amperes). Trip
units are not interchangeable between frames.
“Complete Circuit Breaker” price includes frame, trip, Cu/Al line, and
load lugs. Units will be shipped unassembled unless specified “must
be factory assembled.” If line lugs are not required on the breaker,
eliminate “WL” from product number and subtract price of line lugs.
To order the frame, trip, and lugs separately, select the required
components from table. Magnetic circuit breakers must be ordered
as components. A complete breaker consists of frame, trip and one
line and one load lug per pole. Price of ordering “Complete Circuit
Breaker” vs. frame, trip, and line and load lugs separately is the
same.
Molded case switches can also be ordered as complete units
(designated Type TKMA---Y) or as separate components. They are
UL listed only as complete units. To indicate required lugs, see the
table below.

MOLDED CASE
CIRCUIT BREAKERS

Accessories
Order accessories from the appropriate table:
—Thermal Magnetic Circuit Breakers, Magnetic Circuit Breakers,
and Molded Case Switches1—pages 3-85 to 3-104.
—MicroVersaTrip Plus or Power+ 4-function J and K frame Solid
State Circuit Breakers—pages 3-85 to 3-104.
—Spectra RMS Breakers—pages 3-83 to 3-84 and 3-92 to 3-104.
—Spectra RMS Breakers with MicroVersaTrip Plus Trip Units or
MicroVersaTrip PM Trip Units—pages 3-83 to 3-84, 3-92 to 3-104
and 3-106 to 3-109.
1Installation of accessories in molded case switches requires dummy trip; see page 3-91

Unless otherwise noted, all circuit breakers are UL listed in File
E–11592. Molded case switches are UL listed in File E–57546.

3

All magnetic only circuit breakers and limiters are UL Component
Recognized in Files E–11592 and E–66390, respectively, unless
otherwise noted.

for information. Dummy trip not required for Tri-Break or Q Line molded case switches.

R Frame—1000/1600/2000 Ampere Molded Case Circuit Breakers
—Solid-state MicroVersaTrip Plus or
MicroVersaTrip PM Trip Unit
—Interchangeable trip unit via rating plugs
—65 and 100 kA ratings available
—Standard and 100% rated versions
—Uses standard Power Break accessories
—Stationary/manual only

Molded Case Circuit Breaker and Switch Terminal
Configuration Code
Order standard Cu/Al lugs by using suffix codes presented. Order
lugs separately if special lugs are required. For optional lugs, see
pages 3-101 and 3-102.
Breaker/Switch
Typ e

Circuit Breakers with MicroVersaTrip Trip Units
—Solid-state construction with MicroVersaTrip Plus
digital rms sensing microprocessor trip units.
—Available in J and K frame construction with
ampere ratings from 60-1200A.
For ordering information see pages 3-80 through 3-82. UL listed,
File E–11592. All breakers are UL listed in File E–11592.
Tri-Break Line
—Integrally Fused Thermal Magnetic Circuit Breakers
—Integrally Fused Magnetic Circuit Breakers
—Integrally Fused Molded Case Switches
These breakers are available in four types. Type TB1 (15-100
amperes) product numbers include frame, trip, line and load lugs,
and current limiters all factory assembled. Types TB4 (125 to 400
amperes), TB6 (300 to 600 amperes) and TB8 (600 to 800 amperes)
include frame, trip and limiters, factory assembled, but do not
include line or load lugs. If line and load lugs are required, order
separately. Unless otherwise noted, TB1, TB4, TB6, and TB8 breaker
components are UL listed in File E–42263. Fused molded case
switches are UL listed in File E–57546.

Suffix
Blank

WL

XL

X2

LL

TQD/TJD

Load Lugs
Only

Line and
Load Lugs

—

Line Lugs
Only

No Lugs

Molded Case
Breakers, Thermal
Magnetic

Load Lugs
Only

Line and
Load Lugs

—

Load Lugs
Only

No Lugs

Molded Case
Switch

Line and
Load Lugs

—

No Lugs

Line Lugs
Only

Load Lugs
Only

Spectra RMS™
Breakers

No Lugs

Order Lugs Separately

J.K.
MicroVersaTrip ®
Breakers

No Lugs

Order Lugs Separately

Mine Duty™
Breakers

No Lugs

Order Lugs Separately

Mag-Break®
Breakers

Line and
Load Lugs

—

—

—

—

TEB, TED, THED

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-38
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
How To Order
Spectra RMS Circuit Breakers with MicroVersa Trip Plus Trip Units
How to Order
—Determine the required breaker frame (i.e., 150, 400, 600, 800, or
1200 amperes), IC rating, and load requirements (UL Standard or
100%). Determine overcurrent protective functions (LI, LSI, LIG,
LSIG). Select frame product number and list price from table on
pages 3-59 to 3-61 and 3-66 to 3-68.
—Select and price the required rating plug from table below. The
sensor rating of frame must match the sensor rating of the rating
plug in table.
—Select and price lugs and lug covers as required from page 3-102
and 3-103.
—Select and price appropriate combination of Power Management
System accessories from pages 3-106 to 3-109.
—Select and price any other accessories from pages 3-83 to 3-84
and 3-92 to 3-100.

MicroVersaTrip Plus and PM Rating Plug Selection —
All Plugs List Price, $106.00

Trip Function Definitions
Long-Time (L)
Short-Time (S)

Instantaneous (I)
Ground Fault (G)

Control Power (CP)

Note: All Spectra RMS breakers with ground fault option will have a
breaker cable. If the breaker is connected to a 3Ø4w or 1Ø3w
service, a terminal block or junction box is required for connection
to the neutral current sensor.

Adjustable current setting
Adjustable long-time delay
Adjustable short-time pick-up
Adjustable short-time delay with I2t
Adjustable short-time delay without I2t
Adjustable pick-up
Adjustable ground fault pick-up
adjustable ground fault delay with I2t
Adjustable ground fault delay without I2t
+24 Vdc control power connection

Circuit Breaker
Frame

Sensor
Rating

150

SGHB, SGHH, SGLB,
SGLL, SGPB, SGPP

Pricing Example
SG600 frame, 400 ampere sensor, 400 ampere rating plug, 100kAIC,
100% rated. Trip functions to include long-time (L), short-time (S),
instantaneous (I) and ground fault. 3-phase/4 wire system with 400
ampere neutral sensor. Load lugs only. 120 Vac shunt trip and two
stage auxiliary switch (2AB) with signal level contacts.

400

600

800
Description

Product Number

Frame
Rating Plug
Load Lugs (3 pole kit)
Terminal Block
400A neutral sensor
120 Vac Shunt Trip
2AB Aux. Switch

SGPP36BD0400
SRPG400B400
TCLK365
SDCTBA11
TSRG204
SAST1
SAUXGAB2

List Price GO-135S
$8987.00
$106.00
$42.00
$110.001
$532.00
$363.00
$295.00

1GO-135PM.

SKHB, SKHH, SKLB,
SKLL, SKPB, SKPP

1200

GO-135S

Rating Plug
Rating (Amperes)

Rating Plug
Product No.

60
80
100
125
150
150
200
225
250
300
350
400
300
400
450
500
600
300
400
500
600
700
800
600
700
800
1000
1200

SRPG150B60
SRPG150B80
SRPG150B100
SRPG150B125
SRPG150B150
SRPG400B150
SRPG400B200
SRPG400B225
SRPG400B250
SRPG400B300
SRPG400B350
SRPG400B400
SRPG600B300
SRPG600B400
SRPG600B450
SRPG600B500
SRPG600B600
SRPK800B300
SRPK800B400
SRPK800B500
SRPK800B600
SRPK800B700
SRPK800B800
SRPK1200B600
SRPK1200B700
SRPK1200B800
SRPK1200B1000
SRPK1200B12002

2Not suitable for use with 100% rated, 1000A breaker frame.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-39
Prices and data subject to change without notice

MOLDED CASE
CIRCUIT BREAKERS

—When ordering, specify separate product numbers as follows:
—Frame
—Rating Plug
—Lugs
—Power Management Accessories
—Other Accessories

3

Molded Case Circuit Breakers

Industrial Circuit Breakers
Spectra RMS Circuit Breakers with
MicroVersaTrip PM Trip Units

MOLDED CASE
CIRCUIT BREAKERS

MicroVersaTrip PM Trip Unit
The MicroVersaTrip PM trip unit adds power management system
capability, advanced metering, and protective relays to the basic
functions of MicroVersaTrip Plus. MicroVersaTrip PM trip units
communicate directly on the GE POWER LEADER communications
bus. Suitable for use in applications from 45 Hz to 66 Hz. Not suitable
for 400 Hz.

3

Standard Features
—Adjustable Long-Time (L) pickup, 0.5-1.0X, and delay (3-4 bands).
—Adjustable Instantaneous (I) pickup, 1.5-10X.
—Local Overload and Short-Circuit Trip Indicators (T) with overload
pickup warning.
—Interchangeable trip rating plugs with test set jack for TVRMS test set.
—Digital LCD display with four-button keypad for function selection
and set point adjustment and sealable, clear Lexan cover for
tamper-resistant settings.
—True rms sensing for accurate response to high harmonic content
waveforms.
—EMI immunity per ANSI C37.90.
—POWER LEADER Communications System Link with userselectable address assignment for COMNET communication.
—Metering
—3-Phase Ammeter with ±4% accuracy.
—3-Phase Voltmeter, ±2% @ 1X, configurable for Wye and Delta
systems.
—Frequency Meter, ±1 Hz
—kW Meter, ±7% (real power)
—kVA Meter, ±6% (apparent power)
—kWh Meter, ±6% (energy)
Control Power 24 Vdc provides connection capability for +24 Vdc
control power into the breaker via the distribution cable system.

Note: MicroVersaTrip PM functions require 24 Vdc control power
and voltage sensing signals.
Universal Internal Accessories—Uses the same front-mounted,
field-installable shunt trips, undervoltage releases, bell alarms, and
auxiliary switches as standard Spectra RMS breakers.
Accessory Lead Routing Left or Right—Side channels mean no extra
space required for accessory leads.
Current Limiting—SG600 frames rated 65kA and 100kA @ 480 Vac
are UL listed as current limiting.
Reverse Feed—Front-mounted interchangeable rating plugs mean
all frames are UL listed for reverse feed.
Wide Current Setting Range—Interchangeable rating plugs
combined with 5 current sensors and 0.5-1.0X long time pickup
yield ampere ratings from 30 to 1200A.
100% Continuous Current Rated—Optionally available for 100% UL
continuous current rating applications.

Optional Features
—Adjustable Short-Time (S) pickup, 1.0-9.0C, and delay (4 bands)
with I 2t IN/OUT selection.
—Adjustable Ground fault (G) pickup, 0.2-1.0S, and delay (4 bands)
with I 2t IN/OUT selection and trip indicator. The 4 short-time and
ground fault delay bands provide broader system selectivity.
—Protective Relays—User selectable in any combination from
1 to 5 relays
—Current Unbalance Relay
—Undervoltage Relay
—Overvoltage Relay
—Voltage Unbalance Relay
—Power Reversal Relay

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-40
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
Spectra RMS Circuit Breakers with
MicroVersaTrip PM Trip Units

MicroVersaTrip PM Trip Unit Characteristics
Current Setting (C)
Pickup (Multiple of
Rating Plus Amperes) (X)
0.50 to 1.0 in
increments of 0.05
(11 Settings)

Pick-Up (Multiple of
Current Settings) (C)

Delay (Seconds)

Adjustable
Instantaneous Pickup
(Multiple of Rating
Plug Amperes) (X)

1.5 to 9.0 in
increments of 0.5
(16 Settings)

I2t IN3 0.44 I2T OUT4
0.1, 0.2, 0.3, 0.4
(8 Bands)

1.5 to 10.0 in
increments of 0.5
(18 Settings)

Long-Time1

Short-Time

Delay (Seconds)
2.4,4.9,9,8,20
(3-4 Bands)

2,3

Ground Fault
Pick-Up (Multiple of
Sensor Ampere Rating) (S)
0.2 to 1.0 in
increments of 0.05
(17 Settings)

Delay (Seconds)
I2t IN5 0.41 I2t OUT4
0.1, 0.2, 0.3, 0.4
(8 Bands)

X = Rating Plug Amperes
S = Sensor Ampere Rating
C = Long-Time Current Settings (Pickup)
C = X Times Long-Time Pickup Setting
1 Pick-up fixed at 1.1C.
2 20-second delay (band) not available on SG frames.
3 Time delay at 600% of current setting at lower limit of each band.
4 Time delay shown at lower limit of each band. Pickup tolerances ± 10%. Ground Fault Pick-up not to exceed 1200 amperes.
5 Time delay at 200% of pickup setting at the lower limit of each band.

PM Trip Unit
Metering (M)

Accuracy and Description

Metering and Relaying (PM)

Amperes (A)

Current ±4% Selectable Phase

•

•

Voltage (V)

Volts ±2% Selectable Phase in L-L or L-N

•

•

Energy (kWh/MWh)

Watt hours ±7% Total energy flow through breaker

•

•

Real Power (kW/MW)

Watts ±6% L-L or L-N Power

•

•

Apparent Power (kVA/MVA)

Volt amps ±6% L-L or L-N Power

•

•

Frequency (45-66 Hz)

Hertz ±6%

•

•

Voltage Unbalance Relay

Adjustable pickup, 10 to 50%
Adjustable delay, 1 to 15 seconds or OFF

•

Current Unbalance Relay

Adjustable pickup, 10 to 50%
Adjustable delay, 1 to 15 seconds or OFF

•

Undervoltage Relay

Adjustable pickup, 50 to 90%
Adjustable delay, 1 to 15 seconds or OFF

•

Overvoltage Relay

Adjustable pickup, 110 to 150%
Adjustable delay, 1 to 15 seconds or OFF

•

Power Reversal Relay

Adjustable pickup, 0.01 MW to .90 MW
Adjustable delay, 1 to 15 seconds or OFF

•

Communications

POWER LEADER™ Communications System Link (comment)

•

•

MOLDED CASE
CIRCUIT BREAKERS

Functions

3

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-41
Prices and data subject to change without notice

Molded Case Circuit Breakers

Industrial Circuit Breakers
Spectra RMS Circuit Breakers with
MicroVersaTrip PM Trip Units

How to Order
—Determine the required breaker frame (i.e., 150, 400, 600, 800, or
1200 amperes), IC rating, and load requirements (UL Standard or
100%). Determine overcurrent protective functions (LI, LSI, LIG,
LSIG) and whether protective relaying is required. Select frame
product number and list price from table on pages 3-59 to 3-61
and 3-66 and 3-68.
—Select and price the required rating plug from table below. The
sensor rating of frame must match the sensor rating of the rating
plug in table.
—Select and price lugs and lug covers as required from page 3-102
and 3-103.
—Select and price appropriate combination of Power Management
System accessories from pages 3-106 to 3-109.
—Select and price an auxiliary switch as required from page 3-109.
—Select and price any other accessories from pages 3-83 to 3-84
and 3-92 to 3-100.
—When ordering, specify separate product numbers as follows:
—Frame
—Rating Plug
—Lugs
—Auxiliary Switch
—Power Management System Accessories
—Other Accessories
Trip Unit Function Definitions

MOLDED CASE
CIRCUIT BREAKERS

Long-Time (L)

3

Short-Time (S)

Instantaneous (I)
Ground Fault (G)

Trip Indication Targets
Full Metering (Standard)

Protective Relay Functions

Adjustable current setting
Adjustable long-time delay
Adjustable short-time pick-up
Adjustable short-time delay with l2t
Adjustable short-time delay without l2t
Adjustable pick-up
Adjustable ground fault pick-up
Adjustable ground fault delay with l2t
Adjustable ground fault delay without l2t
Standard
Amperes (A/kA) – Phase Selectable
Voltage (V) – L-L or L-N and Phase Selectable
Energy (kWh/MWh)
Real Power (kW) – L-L or L-N
Total Power (kVA) – L-L or L-N
Frequency (45-66 Hz)
Adjustable Undervoltage pick-up
Adjustable Undervoltage delay or OFF
Adjustable Overvoltage pick-up
Adjustable Overvoltage delay or OFF
Adjustable Voltage Unbalance pick-up
Adjustable Voltage Unbalance delay or OFF
Adjustable Current Unbalance pick-up
Adjustable Current Unbalance delay or OFF
Adjustable Power Reversal pick-up
Adjustable Power Reversal delay or OFF

overvoltage (OV) and power reversal (PR). Local metering values
available at the breaker shall include Current (Amperes), Voltage
(Volts), Energy (kWh), Real Power (kW), Apparent Power (kVA) and
Frequency (Hz). The available system is 277/480 Vac, 3-phase/4-wire
with 100 kAIC fault current available. The Distribution Cable
Accessories are to be mounted on plates with all the necessary fuse
protection, potential transformers, control power transformers, etc.
Description
Frame
Rating Plug
Line and Load Lugs
(2-3 Pole Kits)
Auxiliary Switch
Power Supply Plate
Voltage Conditioner Plate
Junction Box
Harness (2)
400A Neutral Current Sensor

Product Number

List Price

GO Schedule

SGPP36DD0400
SRPG400B400

$11387.00
$106.00

135PM
135S

$42.00
$149.00
$1215.00
$1000.00
$155.00
$140.00
$532.00

135S
135S
135PM
135PM
135PM
135PM
135S

TCLK635
SAUXPAB1
SPSA480
SVCA480Y
SDCJBA
SPCHA11
TSRG204

MicroVersaTrip Plus and PM Rating Plug Selection—
All Plugs List Price, $106.00
Circuit Breaker
Frame

Sensor
Rating

150

SGHB, SGHH, SGLB,
SGLL, SGPB, SGPP

400

600

800

Pricing Example
SG600 ampere frame breaker, 100% UL rated with 400 ampere sensors
and 400 ampere rating plug with line and load lugs. Trip functions to
include adjustable long-time (L), short-time (S), instantaneous (I) and
equipment ground fault (G) and internal protective relay functions of
current unbalance (CU), voltage unbalance (VU), undervoltage (UV),

SKHB, SKHH, SKLB,
SKLL, SKPB, SKPP

1200

Rating Plug
Rating (Amperes)
60
80
100
125
150
150
200
225
250
300
350
400
300
400
450
500
600
300
400
500
600
700
800
600
700
800
1000
1200

GO-135S
Rating Plug
Product No.
SRPG150B60
SRPG150B80
SRPG150B100
SRPG150B125
SRPG150B150
SRPG400B150
SRPG400B200
SRPG400B225
SRPG400B250
SRPG400B300
SRPG400B350
SRPG400B400
SRPG600B300
SRPG600B400
SRPG600B450
SRPG600B500
SRPG600B600
SRPK800B300
SRPK800B400
SRPK800B500
SRPK800B600
SRPK800B700
SRPK800B800
SRPK1200B600
SRPK1200B700
SRPK1200B800
SRPK1200B1000
SRPK1200B12001

1Not suitable for use with 100% rated, 1000A breaker frame.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-42
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
R-Frame Molded Case Circuit Breakers
Solid-State Interchangeable Trip
400-2000A, 600 Vac, 65,100 kAIC @480V
Standard and 100% Rated
MicroVersaTripPlus
Suitable for Reverse Feed
How To Order:
1. Select frame product number.
2. Select rating plug for current rating from page 3-71.
3. Select appropriate accessories and lugs from page 3-105.
Include suffix “s” for factory installation.
Example
Description
Frame
Rating Plug
Neutral CT
Shunt Trip
Auxiliary Switch
Padlocking Provision
Line Side Terminations (Optional)
Load Side Terminations Adapter Kit
Lugs (2 per pole)

Product Number
TRPP36BD10
TR10B600
TSVG810A
TPST12
TPAS2AB4
Standard
(3)TP16FCA
(1)TPLUGA16
(6)TPLUG108

R-Frame UL Listed Interrupting Ratings - rms
Symmetrical Amperes
Continuous Current Rating
Frame Type

80%

100%

Standard Break

LA

LL

Interrupting Rating (rms sym.)
240 Vac 100,000 Amperes
480 Vac 65,000 Amperes
600 Vac 50,000 Amperes
240 Vac 125,000 Amperes

Hi-Break®

PA

PP

480 Vac 100,000 Amperes

MOLDED CASE
CIRCUIT BREAKERS

600 Vac 65,000 Amperes

MicroVersaTrip Plus Trip Unit Selection Trip Unit Function Definitions
Long-Time (L)

Adjustable current setting
Adjustable long-time delay

Short-Time (S)

Adjustable short-time pick-up
Adjustable short-time delay with I2t
Adjustable short-time delay without I2t

Instantaneous (I)

Adjustable pick-up

Ground Fault (G)

Adjustable ground fault pick-up
Adjustable ground fault delay with I2t
Adjustable ground fault delay without I2t

Trip Indication Target (T1, T2)

Overload/short circuit targets (T1)
Overload/short circuit/ground fault targets (T2)

Zone Selective Interlock (Z1, Z2)

Ground fault (Z1)
Ground fault/short-time (Z2)

3

Trip Unit Functions Available

OL, SC

OL,
SC, GF

Zone
Interlock
GF (Z1) 2

Zone
Interlock
GF, ST
(Z2)

•

—

—

—

•

—

—

—

•

—

•

—

—

•

•

—

•

—

—

•

•

—

•

•

—

•

•

—

•

•

—

•

•

—

•

—

•

Targets (T)

R-Frame
Breaker
Function Code

Long
Time (L)

Short
Time (S)

Instantaneous
(I)

A

•

—

•

—

B

•

•

•

—

C

•

—

•

D

•

•

E

•

—

F

•

•

G

•

•

Ground
Fault (G) 1

1

For single-phase, 3-wire or 3-phase, 4-wire GF applications select neutral-current sensor on page 3-105.
2
Zone interlocking requires purchase of interlock module TIM1 (120 Vac control voltage).

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-43
Prices and data subject to change without notice

Molded Case Circuit Breakers

Industrial Circuit Breakers
15-1200A Circuit Breakers
Electric Trip Spectra RMS Breakers
Quick Reference Guide
Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the
table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied
at the given circuit voltage in any electrical distribution system where the available fault current at
the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may
also be applied at intermediate values of circuit voltage provided the available fault current at the
load terminals of the breaker does not exceed the value in the table for the higher value of voltage.

Spectra RMS Circuit Breakers UL/CSA Ratings
Solid-State with Interchangeable Trip Unit (Rating Plug)
Circuit
Breaker
Type

Ampere
Rating

No.
Poles

Maximum
Vac

H

W

D

A

B

C

E

Approx. Ship
Wt./Std.
Pack

6.31
(160)

4.12
(105)

3.38
(86)

2.41
(61)

2.47
(63)

.69
(18)

.72
(18)

5.65 lb/
1

10.12
(257)

4.12
(105)

3.81
(97)

3.87
(98)

3.87
(98)

.69
(18)

1.19
(30)

9.15 lb/
1

10.09
(256)

5.50
(140)

3.81
(97)

4.45
(113)

3.30
(84)

.91
(23)

1.18
(30)

15.85 lb/
1

UL Listed Interrupting Rating— kA
240 Vac

480 Vac

Dimensions Inches (mm)

600 Vac

SE150 Current Limiting (UL File No. E-11592; CSA LR 40350) 1
SED2
15-150
SEH2

SEL
15-150
SEP

2

480

3

600

2

480

3

600

2

480

3

600

2

480

3

600

—
18

18
14
—

65

25

100

65

200

100

18
—
25
—
25

SF-250 Current Limiting (UL File No. E-11592; CSA LR 40350) 1
SFH2

70-250

SFL
70-250
SFP

2

480

3

600

2

480

3

600

2

480

3

600

—
65

35
22
—

100

65
25
—

200

100
25

SG600 Current Limiting (UL File No. E-11592; CSA LR 40350) 3
SGH12,4

60-150

SGD

MOLDED CASE
CIRCUIT BREAKERS

125-400

3

SGH42
SGH62

250-600

4

SGL1

SGP14

3

600

65

35

25

240

65

—

—

65

35

25

2

2

60-150

SGL4
125-400
SGP4

SGL6
250-600
SGP6

3
2

600

3

600

2

600

65

35

25

3

600

3

600

100

65

65

3

600

200

100

65

2

600

3

600

100

65

65

2

600

3

600

200

100

65

2

600

3

600

100

65

65

2

600

3

600

200

100

65

600

65

50

25

600

100

65

42

600

200

100

65

600

65

50

25

600

100

65

42

600

200

100

65

5

5

SK1200 (UL File No. E-11592; CSA LR 40350) 3
2

SKH8

3
SKL8

300-800

2
3
2

SKP8

3
2

SKH12

15.50
(394)

SKL12

SKP12

600-1200

3
2
3

1 UL listed as HACR (heating, air conditioning and refrigeration) type.
2 Not current-limiting circuit breaker.
3 Includes MicroVersaTrip Plus Trip Units and MicroVersaTrip PM Trip Units.

5.50
(140)

8.56
(217)

5.69
(145)

1.38
(35)

.62
(16)

6

3
2

8.25
(210)

47.6 lb/
1

6

4 MicroVersaTrip Plus™ Trip Units and MicroVersaTrip PM™ Trip Units only.
5 Add 1.76 inches (45 mm) to each end with lugs and lug cover installed.
6 Add 4.00 inches (101 mm) to upper end for SKP (100 kAIC-480V) lug cover.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-44
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
15-1200A Circuit Breakers
Electric Trip Spectra RMS Breakers
Quick Reference Guide
Ratings do not apply to molded case switches
IEC/JIS Ratings
Solid-State with Interchangeable Trip Unit (Rating Plug)
Japanese Industry Standard
Interruption Capacity kA

IEC 947-2 Interruption Capacity — kA
Circuit
Breaker
Type

Ampere
Rating

No.
Poles

220-240 Vac
Icu

I cs

380-415 Vac
I cu

I cs

500 Vac
I cu

I cs

690 Vac
I cu

I cs

Vac
220-240 380-415

500

690

SE150 Current Limiting, 15-32A
2

SED

3

15-32

2

SEH

3
2

SEL

3

15-32

2

SEP

3

18

9

10

5

65

33

15

10

100

50

20

15

200

100

20

20

18

9

14

7

65

33

35

17

—

—

4
—

4
—

6
—

6
—

8
—

—
—

—

18

10

—

—

65

15

—

—

8
—

3
—

3
—

100

20

10

10

5

5

200

20

—

—

14
—

7
—

—

—

18

14

25
—

12
—

—

—

65

25

—

—

40
—

20
—

5
—

5
—

4
—
6
—

—
—
—

8
—

3
—

10

5

SE

SE150 Current Limiting, 40-160A
2

SED

3

40-160

2

SEH

3
2

SEL

3

40-160

2

SEP

3

100

50

65

33

200

100

100

50

65

33

35

17

50

25

—

—

25
—

12
—

40
—

20
—

—

10

5

—

—

—

—

14
—

7
—

100

65

200

100

65

25

14
—

—
—

18
—

—

25
—

5
—

65

10

SF250 Current Limiting
70-250

2
3
2

SFL
70-250
SFP

3
2
3

SG600 Current Limiting
—
60-150
SGH11
3

100

50

65

33

200

100

100

50

65

33

25

13

65

33

25

13

65

33

25

13

2
SGH4

125-400

3
2

SGH6

250-600

SGL11
60-150
SGP11

3
—
3
—
3

100

50

65

33

200

100

100

50

100

50

65

33

200

100

100

50

100

50

65

33

200

100

100

50

65

16

50

100

25

140

2
SGL4

3
125-400

SGP4

3
250-600

SGP6

200

100

18

9

—

—

65

25

—

—

65

25

65

25

100

65

200

100

100

65

200

100

100

65

200

100

—

—

18
—

9
—

18
—

9
—

18
—

9
—

—

—

—

—

35
—

18
—

14
—

7
—

50
—

25
—

18
—

9
—

25
—

14
—

65

18

SF

—
18
—
18
—
18
—

—
—
—
—

35
—

22
—

65
—

35
—

35

22
—

65
—

35
—

35
—

22
—

65

35

14
—

7

50
—

25
—

18
—

9
—

35
—

18
—

14
—

7
—

50

25

18

9

13

25

13

—

—

65

50

25

—

65

16

42

21

14

14

100

65

42

14

35

85

25

50

25

18

18

140

85

50

18

65

16

50

13

25

13

—

—

65

50

25

—

100

25

65

21

42

16

14

14

100

65

42

14

140

35

70

25

50

25

18

18

140

85

50

18

2
3

65

18
—

2
SGL6

33

100

—
—

35
—

2
3

65

—
18
—

MOLDED CASE
CIRCUIT BREAKERS

SFH

3
SG

SK1200
2
SKH8
SKL8

3
300-800

3
2

SKH12

SKP12
1

3
2

SKP8

SKL12

2

3
600-1250

2
3
2
3

SK

MicroVersaTrip Plus™ trip system only.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-45
Prices and data subject to change without notice

Molded Case Circuit Breakers

Industrial Circuit Breakers
10-1200A Circuit Breakers
Thermal Magnetic Trip
Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the table are maximum ratings. A circuit
breaker of the type given in the left-hand column may be applied at
the given circuit voltage in any electrical distribution system where
the available fault current at the load terminals of the breaker does
not exceed the value in the table. That circuit breaker type may also
be applied at intermediate values of circuit voltage provided the
available fault current at the load terminals of the breaker does not
exceed the value in the table for the higher value of voltage.

TFJ, TFK, THFK

TJJ, TJK, THJK

Quick Reference Guide
E150 (UL File E-11592; Fixed Thermal Magnetic Trip Unit; CSA LR 57114)

Circuit
Breaker
Type

TEB2

Ampere
Rating

10-1003

ac

dc

120

1

120

125

10

2

240

THED2

250
—

1

277,3474

125

2

480

250

10-150

3

600

500

15-30

1

277,3474

125

15-100

2

480

250

10-1003
15-100

15-100

Vac

No.
Poles

3
TED2

UL Listed Interrupting Ratings— kA

Maximum
Voltage Rating

3

480,600

—

—

120/
240

15-150

277

480

—

—

10

—

—

—

14

10

18

—

18

250

500 1

—

—

—

5
—

—

—

5
—

—

4 1/8

10

—

—

1 3/8

10

—

10

10

4 1/8

11/16

28 lb/8

—

—

1 3/8

—

26 lb/24

205

—

10

—

—

—

—

—
14

—

—

—

—

205

—

65
65

—

65

Approx.
Ship
Wt./Std.
Pack

125

—

—

Dimensions (In.)

600

—

110-150
TEL6

240

Vdc

—

25

18

—

65

25

—

H

W

D

A

B

1 3/8
6 5/16

6 5/16

2 3/4

2 3/4

6 5/16

C

E

26 lb/24

—
3 3/8

2 41/64 2 15/64

23/32
11/16

28 lb/8
26 lb/24

—
3 3/8

3 3/8

2 41/64 2 15/64

23/32

2 41/64 2 15/64

4 1/8

24 lb/12

23/32
11/16

24 lb/12

24 lb/12
28 lb/8

42
3

600

—

—

100

100

—

6 5/16

4 1/8

3 29/32 2 7/16 2 15/32 11/16 23/32

3 1/2 lb/1

F225 (UL File E-11592; TFJ, Fixed Thermal Magnetic Trip Unit; TFK, THFK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)
UL Listed Interrupting Ratings— kA

MOLDED CASE
CIRCUIT BREAKERS

Circuit
Breaker Ampere
Type
Rating

3

2

TFJ

TFK2

No.
Poles

ac

dc

70-225

2

480

250

70-250

3

600

500

70-225
2

Maximum
Voltage Rating

THFK

70-225

TFL6

70-225

2

480

250

3

600

—

2

480

250

3

600

—

3

600

—

Vac
120

120/
240

240

277

480

600

250

500 1

10

—

10

10

10

—

—

—

20 5
—

—

—

—

—

—

—

125

—
—

—

25

—

Dimensions (In.)

Vdc

22

—
18
—

—

—

25

—

22

—

—

65

—

25

—

100

100

—

65

18

—

—
18
25

H

W

D

A

B

10 1/8

4 1/8

3 13/16

3 7/8

3 7/8

C

E

11/16 1 3/16

Approx.
Ship
Wt./Std.
Pack
10 lb/1
12 lb/1

10 1/8

4 1/8

3 13/16

3 7/8

3 7/8

11/16 1 3/16

10 1/8

4 1/8

3 13/16

3 7/8

3 7/8

11/16 1 3/16

10 1/8

4 1/8

3 13/16

3 7/8

3 7/8

10 lb/1
12 lb/1
10 lb/1
12 lb/1

11/16 1 3/16

—

J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)
TJJ,
TJK4

125-400

TJK6

250-600

THJK4

2

600

125-400

250-600

—

—

42

—

30

22

—

10

—

20
10

3

500

20

20

2

250

40

—

—

—

40

—

—

—

2

500
600

600

3
THJK6

250

20 8
—

3

2

600

3

250

—
250
—

—

—

—

—

—

—

42

65

65

—

—

—

30

35

35

22

25

25

—

—

—

10 1/8

8 1/4

3 13/16 3 15/16 3 13/16 1 3/8

1 3/16

16 lb/1
17 1/2 lb/1

10 1/8

8 1/4

3 13/16 3 15/16 3 13/16 1 3/8

1 3/16

18 lb/1
20 lb/1

10 1/8

8 1/4

3 13/16 3 15/16 3 13/16 1 3/8

1 3/16

16 lb/1
17 1/2 lb/1

10 1/8

8 1/4

3 13/16 3 15/16 3 13/16 1 3/8

1 3/16

18 lb/1
20 lb/1

K1200 (UL File E-11592; Interchangeable Thermal Magnetic Trip Unit; CSA LR 40350)
TKM8

300-800

2

600

TKM12

600-1200

2

250

—

—

42

—

30

22

—

500

3
600

—

—

—

42

—

30

22

—

10

—

20

22

—

—

15 1/2

8 1/4

5 1/2

8 9/16 5 11/16 1 3/8

5/8

15 1/2

8 1/4

5 1/2

8 9/16 5 11/16 1 3/8

5/8

39 lb/1

300-800

2

600

3
THKM12 600-1200

2

38 lb/1
41 1/2 lb/1

3
THKM8

33 lb/1

600

250
—
—

—

—

65

—

35

25

—

—

—

65

—

35

25

—

407

—

—

—

—

—

15 1/2

8 1/4

5 1/2

8 9/16 5 11/16 1 3/8

5/8

15 1/2

8 1/4

5 1/2

8 9/16 5 11/16 1 3/8

5/8

33 lb/1
39 lb/1
38 lb/1
41 1/2 lb/1

3
5 UL listed at 10,000 amps.
6 Discontinued

1UL listed with poles in series for 500 Vdc ungrounded battery applications.
2 All UL listed as HACR type.
3 10 amp not UL listed.
4 UL listed/CSA Certified for 10kA @ 347 Vac (TED) and 18kA @ 347V

7 Also 10,000 amps at 500 Volts dc. Not UL listed.
8 500 Vdc on TJK only.

(THED). Also rated 10kA @ 480V but not UL listed.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-46
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Molded Case Circuit Breakers
Quick Reference Guide
Ratings do not apply to molded case switches. The interruption ratings and voltages shown in the table are maximum ratings. A circuit
breaker of the type given in the left-hand column may be applied at
the given circuit voltage in any electrical distribution system where
the available fault current at the load terminals of the breaker does
not exceed the value in the table. That circuit breaker type may also
be applied at intermediate values of circuit voltage provided the
available fault current at the load terminals of the breaker does not
exceed the value in the table for the higher value of voltage.

TJC

TJL6S

R Frame1 (UL File E-11592; Interchangeable Solid-State MicroVersaTrip Plus Trip Unit; CSA LR 10263)
UL Listed Interrupting Ratings—
rms Symmetrical Amps (In Thousands)

Maximum
Voltage
Rating

Circuit
Breaker
Type

Ampere
Rating

No.
Poles

ac

dc

120

120/240

240

277

480

600

125

250

H

W

D

A

B

C

E

Approx.
Ship
Wt./Std.
Pack

TRL…10, 16

400-1600

3

600

—

—

—

100

—

65

50

—

—

17 1/2

13 1/2

8 5/16

—

—

—

—

90/1

TRP…10, 16

400-1600

3

600

—

—

—

125

—

100

65

—

—

17 1/2

13 1/2

8 5/16

—

—

—

—

90/1

TRL…20

800-2000

3

600

—

—

—

100

—

65

50

—

—

20

13 1/2

8 5/16

—

—

—

—

96/1

TRP…20

800-2000

3

600

—

—

—

125

—

100

65

—

—

20

13 1/2

8 5/16

—

—

—

—

96/1

—

200

200

—

—

10 5/16

4 1/8

3 5/8

2 21/32

Vac

Vdc

Dimensions (In.)

Tri-Break (UL File E-42263; Integrally Fused, Thermal Magnetic Trip Unit)
TB12,3

15-100

3

600

—

—

—

200

6 9/32 11/16 23/32

TB42,4

125-400

TB62,4

300-600

3

600

—

—

—

200

—

200

200

—

—

21 7/8

8 1/4

5 7/8

8 9/16

12 1/16

1 3/8

5/8

TB82,4

600-800

3

600

—

—

—

200

—

200

100

—

—

21 7/8

8 1/4

5 7/8

8 9/16

12 1/16

1 3/8

5/8

3

600

—

—

—

200

—

200

200

—

—

16 1/8

8 1/4

4 1/2

3 15/16

9 13/16

1 3/8 1 3/16

8 lb/1
31 lb/1
33 lb/1
53 lb/1
55 lb/1
53 lb/1
55 lb/1

TEC

3-150
6

2

480

250

3

600

—

—

—

10
—

—

10

10

—

10

6 5/16

4 1/8

3 3/8

2 41/64

2 15/64 11/16 23/32

21 lb/6
3 1/2 lb/1

TEML

3-150

3

600

250

—

—

100

—

65

25

—

—

6 5/16

4 1/8

3 7/8

2 41/64

2 15/64 11/16 23/32

TEC &
TECL7

3-150

3

600

—

—

—

100

—

100

100

—

—

8 3/16

4 1/8

3 3/8

2 41/64

1.2 lb/1
2 15/64 11/16 23/32 TECL Only

225

3

600

—

—

—

25

—

22

18

—

—

10 1/8

4 1/8

3 13/16

3 7/8

TFC

3 7/8

11/16 1 3/16

10 lb/1
12 lb/1

TBC4

225-400

3

600

—

—

—

100

—

100

100

—

—

16 1/8

8 1/4

4 1/2

3 15/16

9 13/16

1 3/8 1 3/16

31 lb/1
33 lb/1

TJC

400-600

3

600

—

—

—

42

—

30

22

—

—

10 1/8

8 1/4

3 13/16 3 13/16

3 13/16

1 3/8 1 3/16

16 lb/1
17 1/2/1

TBC6

600

3

600

—

—

—

100

—

100

100

—

—

21 7/8

8 1/4

5 7/8

8 9/16

12 1/16

1 3/8

5/8

TKC

800-1200

3

600

—

—

—

42

—

30

22

—

—

15 1/2

8 1/4

5 1/2

8 9/16

5 11/16

1 3/8

5/8

53 lb/1

MOLDED CASE
CIRCUIT BREAKERS

Mag-Break (UL Files E-11592, E-66390; Magnetic Trip Unit) 5

55 lb/1
38 lb/1
41 1/2/1
TBC8

800

3

600

—

—

—

100

—

100

100

—

—

21 7/8

8 1/4

5 7/8

8 9/16

12 1/16

1 3/8

5/8

53 lb/1
55 lb/1

MicroVersaTrip (UL File E-11592; Solid-State Trip Units)
TJ4V 8,9
THJ4V8,9

150-600

3

600

—

—

TJL4V8

42

42

65

65

100

100

—

30

22

35

25

65

30

—

—

10 1/8

8 1/4

3 13/16 3 15/16

3 13/16

1 3/8 1 3/16

—
—

TK4V8

800-1200

3

600

—

—

42

42

—

30

22

—

—

15 1/2

8 1/4

5 1/2

8 9/16

5 11/16

1 3/8

5/8

TKL4V 8

800-1200

3

600

—

—

100

100

—

65

42

—

—

15 1/2

8 1/4

5 1/2

8 9/16

5 11/16

1 3/8

5/8

60-600

3

600

—

—

65

65

—

35

25

—

—

16 1/8

8 1/4

3 13/16 3 15/16

9 13/16

1 3/8 1 3/16

3 13/16 3 15/16

9 13/16

1 3/8 1 3/16

TJH1S-6S

—
—

60-600

3

600

—

—

100

100

—

65

30

—

—

16 1/8

8 1/4

TKH8S, 12S

300-1200

3

600

—

—

65

65

—

50

25

—

—

21 7/8

8 1/4

5 1/2

8 9/16 12 11/16 1 3/8

5/8

—

TKL8S, 12S

300-1200

3

600

—

—

100

100

—

65

42

—

—

21 7/8

8 1/4

5 1/2

8 9/16 12 11/16 1 3/8

5/8

—

TJL1S-6S

1 Rotary handle (not toggle handle).
2 UL listed with internally mounted accessories at 100,000 amps IC.

Contact GE Sales Office for availability of 200 kAIC ratings with
internal accessories.

—

5 Per UL 489, interrupting capacities are not shown on product label.
6 Discontinued.
7 Ratings shown for TEC in combination with TECL.
8 With Power+ 4 trip unit.
9 Suitable for single-phase, use outer two poles.

3 CSA LR 57114.
4 CSA LR 40350.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-47
Prices and data subject to change without notice

3

Molded Case Circuit Breakers

Industrial Circuit Breakers
15-150A Circuit Breakers
Electronic Trip
Spectra RMS
SE150 Line Circuit Breakers

Features
—Interchangeable trip using rating plugs
—True digital rms sensing
—Universal internal accessories UL listed for field installation
—Adjustable instantaneous with short-time tracking function
—CE marked

SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR
SEL, SEP UL Current Limiting
2-Pole, UL/CSA: 150A, 480 Vac Max., IEC 947-2: 160A, 415 Vac Max.
Rating Plug

Frame

Adj. Inst.
Trip Range Amps

UL 489 IC @480 Vac

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

MOLDED CASE
CIRCUIT BREAKERS

18kA
Ampere
Rating

Low

High

15
20
25
30
40
50
60
70
80
90
100
110
125
150

43
58
73
87
118
148
178
206
236
267
297
328
374
450

182
254
332
415
501
637
777
863
999
1138
1280
1426
1640
1991

Product
Number
SRPE30A15
SRPE30A20
SRPE30A25
SRPE30A30
SRPE60A40
SRPE60A50
SRPE60A60
SRPE100A70
SRPE100A80
SRPE100A90
SRPE100A100
SRPE150A110
SRPE150A125
SRPE150A150

List
Price
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

25kA

Product
Number

List
Price

Product
Number

List
Price

30

SEDA24AT0030

$214.00

SEHA24AT0030

$530.00

60

SEDA24AT0060

$214.00

SEHA24AT0060

$530.00

100

SEDA24AT0100

$312.00

SEHA24AT0100

$634.00

150

SEDA24AT0150

$837.00

SEHA24AT0150

$1427.00

Product
Number

List
Price

TCAL18

$3.00

SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR
2-Pole, UL/CSA: 150A, 480 Vac Max., IEC 947-2: 160A, 415 Vac Max.
Rating Plug

UL 489 IC @480 Vac

Ampere
Rating

Low

High

15
20
25
30
40
50
60
70
80
90
100
110
125
150

43
58
73
87
118
148
178
206
236
267
297
328
374
450

182
254
332
415
501
637
777
863
999
1138
1280
1426
1640
1991

Product
Number
SRPE30A15
SRPE30A20
SRPE30A25
SRPE30A30
SRPE60A40
SRPE60A50
SRPE60A60
SRPE100A70
SRPE100A80
SRPE100A90
SRPE100A100
SRPE150A110
SRPE150A125
SRPE150A150

List
Price
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Wire
Range

12-3/0 Cu
12-3/0 Al

GO-135S

Frame

Adj. Inst.
Trip Range Amps

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

65kA

3

GO-135S

100kA

Current
Sensor

Product
Number

List
Price

Product
Number

List
Price

30

SELA24AT0030

$549.00

SEPA24AT0030

$895.00

60

SELA24AT0060

$549.00

SEPA24AT0060

$895.00

Product
Number

List
Price

TCAL18

$3.00

Wire
Range

12-3/0 Cu
12-3/0 Al

100

SELA24AT0100

$744.00

SEPA24AT0100

$1179.00

150

SELA24AT0150

$1808.00

SEPA24AT0150

$2777.00

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-48
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
15-150A Circuit Breakers
Electronic Trip
Spectra RMS
SE150 Line Circuit Breakers

SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR
3-Pole, UL/CSA: 150A, 600 Vac Max., IEC 947-2: 160A, 690 Vac Max.
Frame

Adj. Inst.
Trip Range Amps

UL 489 IC @480 Vac

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

18kA
Ampere
Rating

Low

High

15
20
25
30
40
50
60
70
80
90
100
110
125
150

43
58
73
87
118
148
178
206
236
267
297
328
374
450

182
254
332
415
501
637
777
863
999
1138
1280
1426
1640
1991

Product
Number
SRPE30A15
SRPE30A20
SRPE30A25
SRPE30A30
SRPE60A40
SRPE60A50
SRPE60A60
SRPE100A70
SRPE100A80
SRPE100A90
SRPE100A100
SRPE150A110
SRPE150A125
SRPE150A150

List
Price
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

Product
Number

25kA
List
Price

Product
Number

List
Price

30

SEDA36AT0030

$382.00

SEHA36AT0030

$632.00

60

SEDA36AT0060

$382.00

SEHA36AT0060

$632.00

100

SEDA36AT0100

$492.00

SEHA36AT0100

$734.00

150

SEDA36AT0150

$1253.00

SEHA36AT0150

$1815.00

Product
Number

List
Price

TCAL18

$3.00

12-3/0 Cu

SE150 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR
3-Pole, UL/CSA: 150A, 600 Vac Max., IEC 947-2: 160A, 690 Vac Max.
Rating Plug

UL 489 IC @480 Vac

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

65kA
Ampere
Rating

Low

High

15
20
25
30
40
50
60
70
80
90
100
110
125
150

43
58
73
87
118
148
178
206
236
267
297
328
374
450

182
254
332
415
501
637
777
863
999
1138
1280
1426
1640
1991

Product
Number
SRPE30A15
SRPE30A20
SRPE30A25
SRPE30A30
SRPE60A40
SRPE60A50
SRPE60A60
SRPE100A70
SRPE100A80
SRPE100A90
SRPE100A100
SRPE150A110
SRPE150A125
SRPE150A150

List
Price
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

12-3/0 Al

GO-135S

Frame

Adj. Inst.
Trip Range Amps

Wire
Range

100kA

Current
Sensor

Product
Number

List
Price

Product
Number

List
Price

30

SELA36AT0030

$753.00

SEPA36AT0030

$1189.00

60

SELA36AT0060

$753.00

SEPA36AT0060

$1189.00

100

SELA36AT0100

$895.00

SEPA36AT0100

$1482.00

150

SELA36AT0150

$2165.00

SEPA36AT0150

$3477.00

Product
Number

List
Price

TCAL18

$3.00

Wire
Range

12-3/0 Cu
12-3/0 Al

3

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

MOLDED CASE
CIRCUIT BREAKERS

Rating Plug

GO-135S

3-49
Prices and data subject to change without notice

Molded Case Circuit Breakers

Industrial Circuit Breakers
15-150A Circuit Breakers
Thermal-Magnetic Trip
E150 Line Circuit Breakers
Types TEB, TED, THED
Noninterchangeable Trip
Note: All UL listed as HACR type except 10 ampere
60°C/75°F Conductor
10-150 Amperes
Rating Through 100 Amperes 120-600 Vac
75°C above 100 Amperes
125, 250 Vdc

Single Pole — Includes Cu/Al load lugs only. If line lugs are required, add suffix “WL” to Product Number.
Type TEB
Ampere
Rating
10
15
20
25
30
35
40
45
50
60
70
80
90
100

Type TED

120 Vac 125 Vdc

347 Vac1

277 Vac 125 Vdc

Product Number

List Price

Product Number

TEB1110102
TEB1110153
TEB1110203
TEB111025
TEB111030
TEB111035
TEB111040
TEB111045
TEB111050
TEB111060
TEB111070
TEB111080
TEB111090
TEB111100

$78.50
$78.50
$78.50
$78.50
$78.50
$78.50
$78.50
$78.50
$78.50
$78.50
$134.00
$134.00
$134.00
$134.00

TED1130102
TED1130153
TED1130203
TED113025
TED113030
TED113035
TED113040
TED113045
TED113050
TED113060
TED113070
TED113080
TED113090
TED113100

GO-135B

Type THED

List Price
$82.50
$82.50
$82.50
$82.50
$82.50
$82.50
$82.50
$82.50
$82.50
$82.50
$159.00
$159.00
$159.00
$159.00

347 Vac1

277 Vac

Product Number

List Price

Product Number

List Price

TED1140153
TED1140203
TED114025
TED114030
—
—
—
—
—
—
—
—
—

$152.00
$152.00
$152.00
$152.00
—
—
—
—
—
—
—
—
—

THED113015
THED113020
THED113025
THED113030
—
—
—
—
—
—
—
—
—

$229.00
$229.00
$229.00
$229.00
—
—
—
—
—
—
—
—
—

Product Number
THED1140153
THED1140203
THED114025
THED114030
—
—
—
—
—
—
—
—
—

Two Pole — Includes Cu/Al load lugs. For optional lugs, see page 3-101 and 3-102.

MOLDED CASE
CIRCUIT BREAKERS

Type TEB

3

240 Vac, 250 Vdc

GO-135B

480 Vac, 250 Vdc

Product Number

List Price

Product Number

10
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150

TEB122010WL2
TEB122015WL
TEB122020WL
TEB122025WL
TEB122030WL
TEB122035WL
TEB122040WL
TEB122045WL
TEB122050WL
TEB122060WL
TEB122070WL
TEB122080WL
TEB122090WL
TEB122100WL
—
—
—

$159.00
$159.00
$159.00
$159.00
$159.00
$159.00
$159.00
$159.00
$159.00
$159.00
$261.00
$261.00
$261.00
$261.00
—
—
—

TED124010WL2
TED124015WL
TED124020WL
TED124025WL
TED124030WL
TED124035WL
TED124040WL
TED124045WL
TED124050WL
TED124060WL
TED124070WL
TED124080WL
TED124090WL
TED124100WL
TED124110WL
TED124125WL
TED124150WL

$416.00
$416.00
$416.00
$416.00
—
—
—
—
—
—
—
—
—

Type THED, Hi-Break 4

Type TED

Ampere
Rating

List Price

List Price
$290.00
$290.00
$290.00
$290.00
$290.00
$290.00
$290.00
$290.00
$290.00
$290.00
$377.00
$377.00
$377.00
$377.00
$1000.00
$1000.00
$1000.00

480 Vac, 250 Vdc
Product Number

List Price

—
THED124015WL
THED124020WL
THED124025WL
THED124030WL
THED124035WL
THED124040WL
THED124045WL
THED124050WL
THED124060WL
THED124070WL
THED124080WL
THED124090WL
THED124100WL
—
—
—

—
$560.00
$560.00
$560.00
$560.00
$560.00
$560.00
$560.00
$560.00
$560.00
$653.00
$653.00
$653.00
$653.00
—
—
—

1Suitable for 10 kAIC at 480 Vac, but not labeled or UL listed.
2Not UL listed
3Single-pole, 15-and 20-ampere breakers are also UL listed as switching duty breakers, suitable for switching 120 Vac (TEB), 277, 347 Vac (TED, THED) fluorescent lighting loads.
4Two-pole breaker is furnished in three-pole case.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-50
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
15-150A Circuit Breakers
Thermal-Magnetic Trip
E150 Line Circuit Breakers
Types TEB, TED, THED
Note: All UL listed as HACR type except 10 ampere
60°C/75°F Conductor
10-150 Amperes
Rating Through 100 Amperes 120-600 Vac
75°C above 100 Amperes
125, 250 Vdc

Three Pole — Includes Cu/Al load lugs. For optional lugs, see page 3-101 and 3-102.
Type TEB

GO-135B

Type TED

240 Vac

Type THED, Hi-Break

480 Vac

Ampere
Rating

Product Number

List Price

Product Number

10
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
100NA
150NA

TEB132010WL1
TEB132015WL
TEB132020WL
TEB132025WL
TEB132030WL
TEB132035WL
TEB132040WL
TEB132045WL
TEB132050WL
TEB132060WL
TEB132070WL
TEB132080WL
TEB132090WL
TEB132100WL
—
—
—
—
—

$240.00
$240.00
$240.00
$240.00
$240.00
$240.00
$240.00
$240.00
$240.00
$240.00
$339.00
$339.00
$339.00
$339.00
—
—
—
—
—

TED134010WL1
TED134015WL
TED134020WL
TED134025WL
TED134030WL
TED134035WL
TED134040WL
TED134045WL
TED134050WL
TED134060WL
TED134070WL
TED134080WL
TED134090WL
TED134100WL
TED134110WL
TED134125WL
TED134150WL
TED134Y1002
TED134Y1502

600 Vac
List Price
$377.00
$377.00
$377.00
$377.00
$377.00
$377.00
$377.00
$377.00
$377.00
$377.00
$445.00
$445.00
$445.00
$445.00
$1198.00
$1198.00
$1198.00
$377.00
$967.00

480 Vac

600 Vac

Product Number

List Price

Product Number

Product Number

List Price

TED136010WL1
TED136015WL
TED136020WL
TED136025WL
TED136030WL
TED136035WL
TED136040WL
TED136045WL
TED136050WL
TED136060WL
TED136070WL
TED136080WL
TED136090WL
TED136100WL
TED136110WL
TED136125WL
TED136150WL
TED136Y1002
TED136Y1502

$439.00
$439.00
$439.00
$439.00
$439.00
$439.00
$439.00
$439.00
$439.00
$439.00
$534.00
$534.00
$534.00
$534.00
$1198.00
$1198.00
$1198.00
$445.00
$967.00

—
THED134015WL
—
—
THED134030WL
—
—
THED134045WL
—
—
THED134070WL
—
THED134090WL
THED134100WL
THED134110WL
THED134125WL
THED134150WL
—
—

—
THED136015WL
THED136020WL
THED136025WL
THED136030WL
THED136035WL
THED136040WL
THED136045WL
THED136050WL
—
THED136070WL
—
THED136090WL
THED136100WL
THED136110WL
THED136125WL
THED136150WL
—
—

—
$655.00
$655.00
$655.00
$655.00
$655.00
$655.00
$655.00
$655.00
—
$742.00
—
$742.00
$742.00
$1683.00
$1683.00
$1683.00
—
—

1Not UL listed.

MOLDED CASE
CIRCUIT BREAKERS

2Includes factory-installed dummy trip.

Accessories: See pages 3-85 to 3-104.

3

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-51
Prices and data subject to change without notice

Molded Case Circuit Breakers

Industrial Circuit Breakers
70-250A Circuit Breakers
Electronic Trip
Spectra RMS
SF250 Line Circuit Breakers

SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR
SFH UL Current Limiting
2-Pole, UL/CSA: 250A, 480 Vac Max., IEC 947-2: 250A, 415 Vac Max.
Rating Plug

GO-135S

Frame

Terminal Lugs for Front Connection (Cu/Al)

UL 489 IC @480 Vac
Adjustable Instantaneous
Trip Ampere Range
Ampere
Rating
Low
High
70
90
100
110
125
150
175
200
225
250

205
265
295
325
370
440
515
590
665
736

700
900
1000
1100
1250
1500
1750
2000
2250
2500

35kA
Product
Number

List
Price

Current
Sensor

Product
Number

List
Price

Product
Number

List
Price

SRPF250A70
SRPF250A90
SRPF250A100
SRPF250A110
SRPF250A125
SRPF250A150
SRPF250A175
SRPF250A200
SRPF250A225
SRPF250A250

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

250

SFHA24AT0250

$1134.00

TCAL29

$8.00

8-350 Cu

SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR
SFL, SFP UL Current Limiting
2-Pole, UL/CSA: 250A, 480 Vac Max., IEC 947-2: 250A, 415 Vac Max.
Rating Plug

MOLDED CASE
CIRCUIT BREAKERS

3

70
90
100
110
125
150
175
200
225
250

205
265
295
325
370
440
515
590
665
736

700
900
1000
1100
1250
1500
1750
2000
2250
2500

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

65kA
Product
Number

List
Price

Current
Sensor

Product
Number

SRPF250A70
SRPF250A90
SRPF250A100
SRPF250A110
SRPF250A125
SRPF250A150
SRPF250A175
SRPF250A200
SRPF250A225
SRPF250A250

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

250

SFLA24AT0250

8-350 Al

GO-135S

Frame
UL 489 IC @480 Vac

Adjustable Instantaneous
Trip Ampere Range
Ampere
Rating
Low
High

Wire
Range

100kA
List
Price

Product
Number

List
Price

Product
Number

List
Price

$2790.00

TCAL29

$8.00

Wire
Range

8-350 Cu
$2175.00 SFPA24AT0250

SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR
SFH UL Current Limiting
3-Pole, UL/CSA: 250A, 600 Vac Max., IEC 947-2: 250A, 690 Vac Max.
Rating Plug

Frame

8-350 Al

GO-135S

Terminal Lugs for Front Connection (Cu/Al)

UL 489 IC @480 Vac
Adjustable Instantaneous
Trip Ampere Range
Ampere
Rating

Low

70
90
100
110
125
150
175
200
225
250

205
265
295
325
370
440
515
590
665
736

35kA

High

Product
Number

List
Price

700
900
1000
1100
1250
1500
1750
2000
2250
2500

SRPF250A70
SRPF250A90
SRPF250A100
SRPF250A110
SRPF250A125
SRPF250A150
SRPF250A175
SRPF250A200
SRPF250A225
SRPF250A250

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

Product
Number

List
Price

Product
Number

List
Price

250

SFHA36AT0250

$1441.00

TCAL29

$8.00

Wire
Range

8-350 Cu
8-350 Al

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-52
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
70-250A Circuit Breakers
Electronic Trip
Spectra RMS
SF250 Line Circuit Breakers

SF250 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350, UL listed HACR
SFL, SFP UL Current Limiting
3-Pole, UL/CSA: 250A, 600 Vac Max., IEC 947-2: 250A, 690 Vac Max.
Rating Plug

Frame
UL 489 IC @480 Vac

Adjustable Instantaneous
Trip Ampere Range
Ampere
Rating
Low
High
205
265
295
325
370
440
515
590
665
736

700
900
1000
1100
1250
1500
1750
2000
2250
2500

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

65kA
Product
Number

List
Price

SRPF250A70
SRPF250A90
SRPF250A100
SRPF250A110
SRPF250A125
SRPF250A150
SRPF250A175
SRPF250A200
SRPF250A225
SRPF250A250

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

100kA

Current
Sensor

Product
Number

List
Price

Product
Number

List
Price

Product
Number

List
Price

250

SFLA36AT0250

$2631.00

SFPA36AT0250

$3490.00

TCAL29

$8.00

Wire
Range

8-350 Cu
8-350 Al

MOLDED CASE
CIRCUIT BREAKERS

70
90
100
110
125
150
175
200
225
250

GO-135S

3

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-53
Prices and data subject to change without notice

Molded Case Circuit Breakers

Industrial Circuit Breakers
70-250A Circuit Breakers
Thermal-Magnetic Trip
F225 Line Circuit Breakers
Types TFJ, TFK, THFK
F225 Line Circuit Breakers
—70-250 Amperes–TFJ Noninterchangeable Trip, suitable for reverse feed
—70-225A TFK, THFK Interchangeable Trip, not suitable for reverse feed
—480 or 600 Vac
—250 Vdc
Note: All TFJ, TFK and THFK breakers are UL listed as HACR

Type TFK

Type TFJ — Noninterchangeable Trip

GO-135B

Adjustable Instantaneous
Trip Ampere Range
Ampere Rating

Low

High

Complete Breaker
480 Vac Max
Product Number

Complete Breaker
600 Vac Max

List Price

Product Number

Two-Pole

List Price

Copper/Aluminum Lugs

70
80
90
100
110
125
150
175
200
225
250

600
700
600
600
660
600
700
800
900
1000
1000

900
1000
900
1250
1250
1250
1500
1750
2000
2250
2250

TFJ224070WL
TFJ224080WL
TFJ224090WL
TFJ224100WL
TFJ224110WL
TFJ224125WL
TFJ224150WL
TFJ224175WL
TFJ224200WL
TFJ224225WL
—

$1122.00
$1122.00
$1122.00
$1122.00
$1122.00
$1122.00
$1122.00
$1122.00
$1122.00
$1122.00
—

TFJ236070WL
TFJ236080WL
TFJ236090WL
TFJ236100WL
TFJ236110WL
TFJ236125WL
TFJ236150WL
TFJ236175WL
TFJ236200WL
TFJ236225WL
TFJ236250WL

$1407.00
$1407.00
$1407.00
$1407.00
$1407.00
$1407.00
$1407.00
$1407.00
$1407.00
$1407.00
$2075.00

TCAL24

4-300 Cu/Al

1

1

Types TFK, THFK — Interchangeable Trip

GO-135B

Complete Circuit Breaker Includes Line and Load Lugs

MOLDED CASE
CIRCUIT BREAKERS

Adjustable
Instantaneous
Ampere Trip Ampere Range
Rating
Low
High

3

Wire Size

Three-Pole

Standard
Product
Number

Two-Pole, 480 Vac Max., 250 Vdc Max.
70
600
900
TFK224070WL
80
700
1000 TFK224080WL
90
600
900
TFK224090WL
100
600
1250 TFK224100WL
110
660
1250 TFK224110WL
125
600
1250 TFK224125WL
150
700
1500 TFK224150WL
175
800
1750 TFK224175WL
200
900
2000 TFK224200WL
225
1000 2250 TFK224225WL
Three-Pole, 600 Vac Max., 250 Vdc Max.
70
600
900
TFK236070WL
80
700
1000 TFK236080WL
90
600
900
TFK236090WL
100
600
1250 TFK236100WL
110
660
1250 TFK236110WL
125
600
1250 TFK236125WL
150
700
1500 TFK236150WL
175
800
1750 TFK236175WL
200
900
2000 TFK236200WL
225
1000 2250 TFK236225WL
225
600
1400
—
Mag
1000 2250
—
Only

Trip Unit Only

Terminal Lugs for
Front Connection (Copper/Aluminum) 2

Frame Only

High-Break
List
Price

Product
Number

List
Price

Use with Standard
and Hi-Break Frames

List
Price

Product
Number

$1122.00
$1122.00
$1122.00
$1122.00
$1122.00
$1122.00
$1122.00
$1122.00
$1122.00
$1122.00

THFK224070WL
THFK224080WL
THFK224090WL
THFK224100WL
THFK224110WL
THFK224125WL
THFK224150WL
THFK224175WL
THFK224200WL
THFK224225WL

$2315.00
$2315.00
$2315.00
$2315.00
$2315.00
$2315.00
$2315.00
$2315.00
$2315.00
$2315.00

TFK226T070
TFK226T080
TFK226T090
TFK226T100
TFK226T110
TFK226T125
TFK226T150
TFK226T175
TFK226T200
TFK226T225

$337.00
$337.00 TFK224F000
$753.00
$337.00 Standard
$337.00 Frame
$337.00
$337.00
$337.00
$337.00 THFK224F000 $1946.00
$337.00 Hi-Break
$337.00 Frame

$1407.00
$1407.00
$1407.00
$1407.00
$1407.00
$1407.00
$1407.00
$1407.00
$1407.00
$1407.00
—
—

THFK236070WL
THFK236080WL
THFK236090WL
THFK236100WL
THFK236110WL
THFK236125WL
THFK236150WL
THFK236175WL
THFK236200WL
THFK236225WL
—
—

$2787.00
$2787.00
$2787.00
$2787.00
$2787.00
$2787.00
$2787.00
$2787.00
$2787.00
$2787.00
—
—

TFK236T070
TFK236T080
TFK236T090
TFK236T100
TFK236T110
TFK236T125
TFK236T150
TFK236T175
TFK236T200
TFK236T225
TFK236TM12253
TFK236TM22253

$445.00
$445.00
$445.00
$445.00
$445.00
$445.00
$445.00
$445.00
$445.00
$445.00
$555.00
$555.00

TFK236F000
Standard
Frame

List
Price

Product Number
(Order 1 line and
1 load per pole)

List
Price

Wire
Size

TCAL24

$8.00

4-300 Cu/Al

TCAL24

$8.00

4-300 Cu/Al

$914.00

THFK236F000 $2294.00
Hi-Break
Frame

1TC024 load end. Wire range #4-300 copper only.
2For optional lug see page 3-101.

Accessories: See pages 3-85 to 3-104.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-54
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
125-400A Circuit Breakers
Thermal-Magnetic Trip
Q Line Circuit Breakers
Types TJD

Two-Pole TJD

GO-135F

TJD Lug-lug 240 Vac1
Ampere Rating

22 kAIC
Product Number

List Price

TJD422250WL
TJD422300WL
TJD422350WL
TJD422400WL
TJD422Y400

$XXXX.00
$XXXX.00
$XXXX.00
$XXXX.00
$XXXX.00

1Includes line and load lugs. For optional configurations, see page 3-21.

Three-Pole TJD

GO-135F

TJD Lug-lug 240 Vac1

TJD432300WL

22 kAIC

Ampere Rating

Product Number

List Price

250
300
350
400
400 Molded Case Switch

TJD432250WL2
TJD432300WL2
TJD432350WL2
TJD432400WL2
TJD432Y4002

$1802.00
$1802.00
$1802.00
$1802.00
$1509.00

1Includes line and load lugs. For optional configurations, see page 3-21.
2TJD uses same accessories as J600 line. TJD not listed HACR.

MOLDED CASE
CIRCUIT BREAKERS

See page 3-4 for size and ratings.

3

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-55
Prices and data subject to change without notice

Molded Case Circuit Breakers

Industrial Circuit Breakers
125-600A Circuit Breakers
Electronic Trip
Spectra RMS
SG600
Digital, Solid-State Spectra RMS Breakers

SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting
UL/CSA: 400A, 600 Vac Max., IEC 947-2: 400A, 690 Vac Max.
Rating Plug

GO-135S

Frame
UL 489 IC @480 Vac

Adjustable
Instantaneous
Trip
Ampere Range
Ampere
Rating Low
High
125
150
175
200
225
250
300
350
400

380
455
530
605
680
755
905
1060
1210

1275
1530
1785
2040
2295
2550
3060
3570
4080

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

65kA (240 Vac)
Product
Number

List
Price

SRPG400A125
SRPG400A150
SRPG400A175
SRPG400A200
SRPG400A225
SRPG400A250
SRPG400A300
SRPG400A350
SRPG400A400

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

List
Price

35kA

Poles

Product
Number

Product
Number

List
Price

2

SGDA22AT04001

$1540.00

SGHA26AT0400

$1959.00

3

SGDA32AT04001

$1860.00

SGHA36AT0400

$2383.00

Product
Number

List
Price

Wire
Range

$28.00

(2) 2/0-500 Cu
or
(1) 8-600 Cu

$42.00

(2) 2/0-500 Al
or
(1) 6-600 Al

2-pole lug kit
TCLK2652

400
3-pole lug kit
TCLK3652

SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting
UL/CSA: 400A, 600 Vac Max., IEC 947-2: 400A, 690 Vac Max.
Rating Plug

GO-135S

Frame
UL 489 IC @480 Vac

MOLDED CASE
CIRCUIT BREAKERS

Adjustable
Instantaneous
Trip
Ampere Range
Ampere
Rating Low
High

3

125
150
175
200
225
250
300
350
400

380
455
530
605
680
755
905
1060
1210

1275
1530
1785
2040
2295
2550
3060
3570
4080

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

65kA
Product
Number

List
Price

SRPG400A125
SRPG400A150
SRPG400A175
SRPG400A200
SRPG400A225
SRPG400A250
SRPG400A300
SRPG400A350
SRPG400A400

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

100kA

Poles

Product
Number

List
Price

Product
Number

List
Price

2

SGLA26AT0400

$2926.00

SGPA26AT0400

$3856.00

3

SGLA36AT0400

$3487.00

SGPA36AT0400

$4653.00

Product
Number

List
Price

Wire
Range

$28.00

(2) 2/0-500 Cu
or
(1) 8-600 Cu

$42.00

(2) 2/0-500 Al
or
(1) 6-600 Al

2-pole lug kit
TCLK2652

400
3-pole lug kit
TCLK3652

SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting
UL/CSA: 600A, 600 Vac Max., IEC 947-2: 630A, 690 Vac Max.
Rating Plug

GO-135S

Frame
UL 489 IC @480 Vac

Adjustable
Instantaneous
Ampere Trip Ampere Range
Rating Low
High
250
300
350
400
450
500
600

765
915
1070
1220
1375
1525
1830

2530
3035
3545
4050
4555
5060
6075

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

35kA
Product
Number

List
Price

SRPG600A250
SRPG600A300
SRPG600A350
SRPG600A400
SRPG600A450
SRPG600A500
SRPG600A600

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

65kA

Poles

Product
Number

List
Price

Product
Number

List
Price

2

SGHA26AT0600

$2663.00

SGLA26AT0600

$3545.00

3

SGHA36AT0600

$3354.00

SGLA36AT0600

$4270.00

Product
Number

List
Price

Wire
Range

$28.00

(2) 2/0-500 Cu
or
(1) 8-600 Cu

2-pole lug kit
TCLK2652

600
3-pole lug kit
TCLK3652

$42.00

(2) 2/0-500 Al
or (1) 6-600 Al

1Rated 240 Vac max.
2Order one kit for either line or load end; two kits required for both.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-56
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
125-600A Circuit Breakers
Electronic Trip
Spectra RMS
SG600
Digital, Solid-State Spectra RMS Breakers

SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting
UL/CSA: 600A, 600 Vac Max., IEC 947-2: 630A, 690 Vac Max.
Rating Plug

GO-135S

Frame

Terminal Lugs for Front Connection (Cu/Al)

UL 489 IC @480 Vac
Adjustable
Instantaneous
Trip
Ampere Range
Ampere
Rating Low
High
250
300
350
400
450
500
600

765
915
1070
1220
1375
1525
1830

2530
3035
3545
4050
4555
5060
6075

100kA
Product
Number

List
Price

SRPG600A250
SRPG600A300
SRPG600A350
SRPG600A400
SRPG600A450
SRPG600A500
SRPG600A600

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

Poles

Product
Number

List
Price

2

SGPA26AT0600

$4607.00

3

SGPA36AT0600

$5548.00

Product
Number

List
Price

Wire
Range

$28.00

(2) 2/0-500 Cu
or
(1) 8-600 Cu

2-pole lug kit
TCLK2651

600
3-pole lug kit
TCLK3651

$42.00

(2) 2/0-500 Al
or (1) 6-600 Al

1Order one kit for either line or load end; two kits required for both.

SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting
100% UL Rated, 3-Pole: 400A, 600 Vac Max.; IEC 947-2: 400A, 690 Vac Max.
Frame
UL 489 IC @480 Vac
Adjustable
Instantaneous
Trip
Ampere Range
Ampere
Rating Low
High
125
150
175
200
225
250
300
350
400

380
455
530
605
680
755
905
1060
1210

1275
1530
1785
2040
2295
2550
3060
3570
4080

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

35kAIC
Product
Number

List
Price

SRPG400A125
SRPG400A150
SRPG400A175
SRPG400A200
SRPG400A225
SRPG400A250
SRPG400A300
SRPG400A350
SRPG400A400

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

Poles

Product
Number

65kAIC
List
Price

Product
Number

List
Price

Product
Number

List
Price

Wire
Range
(2) 2/0-500 Cu
or
(1) 8-600 Cu

400

3

SGHH36AT0400

$4381.00

SGLL36AT0400

$5501.00

TCLK365

$42.00
(2) 2/0-500 Al
or
(1) 6-600 Al

SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting
100% UL Rated, 3-Pole: 400A, 600 Vac Max.; IEC 947-2: 400A, 690 Vac Max.
Rating Plug

Frame

GO-135S

Terminal Lugs for Front Connection (Cu/Al)

UL 489 IC @480 Vac
Adjustable
Instantaneous
Trip
Ampere Range
Ampere
Rating Low
High
125
150
175
200
225
250
300
350
400

380
455
530
605
680
755
905
1060
1210

1275
1530
1785
2040
2295
2550
3060
3570
4080

100kAIC
Product
Number

List
Price

SRPG400A125
SRPG400A150
SRPG400A175
SRPG400A200
SRPG400A225
SRPG400A250
SRPG400A300
SRPG400A350
SRPG400A400

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

Poles

Product
Number

List
Price

Product
Number

List
Price

Wire
Range
(2) 2/0-500 Cu
or
(1) 8-600 Cu

400

3

SGPP36AT0400

$6049.00

TCLK365

$42.00
(2) 2/0-500 Al
or
(1) 6-600 Al

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-57
Prices and data subject to change without notice

MOLDED CASE
CIRCUIT BREAKERS

Rating Plug

GO-135S

3

Molded Case Circuit Breakers

Industrial Circuit Breakers
125-600A Circuit Breakers
Electronic Trip
Spectra RMS
SG600
Digital, Solid-State Spectra RMS Breakers

SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting
100% UL Rated, 3-Pole: 600A, 600 Vac Max.; IEC 947-2: 630A, 690 Vac Max.
Rating Plug

Frame
UL 489 IC @480 Vac

Adjustable
Instantaneous
Trip
Ampere Range
Ampere
Rating Low
High
250
300
350
400
450
500
600

765
915
1070
1220
1375
1525
1830

2530
3035
3545
4050
4555
5060
6075

GO-135S

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

35kAIC
Product
Number

List
Price

SRPG600A250
SRPG600A300
SRPG600A350
SRPG600A400
SRPG600A450
SRPG600A500
SRPG600A600

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

Poles

Product
Number

65kAIC
List
Price

Product
Number

List
Price

Product
Number

List
Price

Wire
Range
(2) 2/0-500 Cu
or (1) 8-600 Cu

600

3

SGHH36AT0600

$5451.00

SGLL36AT0600

$6783.00

TCLK365

$42.00
(2) 2/0-500 Al
(1) 6-600 Al

SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting
100% UL Rated, 3-Pole: 600A, 600 Vac Max.; IEC 947-2: 630A, 690 Vac Max.
Rating Plug

Frame

GO-135S

Terminal Lugs for Front Connection (Cu/Al)

UL 489 IC @480 Vac

MOLDED CASE
CIRCUIT BREAKERS

Adjustable
Instantaneous
Ampere Trip Ampere Range
Rating Low
High
250
300
350
400
450
500
600

765
915
1070
1220
1375
1525
1830

2530
3035
3545
4050
4555
5060
6075

100kAIC
Product
Number

List
Price

SRPG600A250
SRPG600A300
SRPG600A350
SRPG600A400
SRPG600A450
SRPG600A500
SRPG600A600

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

Poles

Product
Number

List
Price

Product
Number

List
Price

Wire
Range
(2) 2/0-500 Cu
or (1) 8-600 Cu

600

3

SGPP36AT0600

$7212.00

TCLK365

$42.00
(2) 2/0-500 Al
or (1) 6-600 Al

3

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-58
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
60-600A Circuit Breakers
Electronic Trip
Spectra RMS
SG600 with MicroVersaTrip Plus and PM

MicroVersaTrip Plus, Standard UL Rated
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max.
Frame

Current
Sensor

150

400

600

Terminal Lugs for Front connection (Cu/Al)

IC @480 Vac, UL 489

IC @480 Vac, UL 489

Trip
Function

35kA
Product Number

List Price

65kA
Product Number

List Price

100kA
Product Number

List Price

LIT
LSIT
LIGT1
LSIGT1
LIT-CP2
LSIT-CP2
LIT
LSIT
LIGT1
LSIGT1
LIT-CP2
LSIT-CP2
LIT
LSIT
LIGT1
LSIGT1
LIT-CP2
LSIT-CP2

SGHB36BA0150
SGHB36BB0150
SGHB36BC0150
SGHB36BD0150
SGHB36BE0150
SGHB36BF0150
SGHB36BA0400
SGHB36BB0400
SGHB36BC0400
SGHB36BD0400
SGHB36BE0400
SGHB36BF0400
SGHB36BA0600
SGHB36BB0600
SGHB36BC0600
SGHB36BD0600
SGHB36BE0600
SGHB36BF0600

$2597.00
$3962.00
$3807.00
$5172.00
$2897.00
$4262.00
$2597.00
$3962.00
$3807.00
$5172.00
$2897.00
$4262.00
$3551.00
$4916.00
$4761.00
$6126.00
$3851.00
$5216.00

SGLB36BA0150
SGLB36BB0150
SGLB36BC0150
SGLB36BD0150
SGLB36BE0150
SGLB36BF0150
SGLB36BA0400
SGLB36BB0400
SGLB36BC0400
SGLB36BD0400
SGLB36BE0400
SGLB36BF0400
SGLB36BA0600
SGLB36BB0600
SGLB36BC0600
SGLB36BD0600
SGLB36BE0600
SGLB36BF0600

$3752.00
$5117.00
$4962.00
$6327.00
$4052.00
$5417.00
$3752.00
$5117.00
$4962.00
$6327.00
$4052.00
$5417.00
$4505.00
$5870.00
$5715.00
$7080.00
$4805.00
$6170.00

SGPB36BA0150
SGPB36BB0150
SGPB36BC0150
SGPB36BD0150
SGPB36BE0150
SGPB36BF0150
SGPB36BA0400
SGPB36BB0400
SGPB36BC0400
SGPB36BD0400
SGPB36BE0400
SGPB36BF0400
SGPB36BA0600
SGPB36BB0600
SGPB36BC0600
SGPB36BD0600
SGPB36BE0600
SGPB36BF0600

$4932.00
$6297.00
$6142.00
$7507.00
$5232.00
$6597.00
$4932.00
$6297.00
$6142.00
$7507.00
$5232.00
$6597.00
$5880.00
$7245.00
$7090.00
$8455.00
$6180.00
$7545.00

Product Number

3-Pole
lug kit
TCLK3653

List Price

Wire Range

$42.00

(2) 2/0-500 Cu
or
(1) 8-600 Cu

(2) 2/0-500 Al
or
(1) 6-600 Al

MicroVersaTrip Plus, 100% UL Rate 4
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max.
Frame
IC @480 Vac, UL 489
Current
Sensor

150

400

600

GO-135S

Terminal Lugs for Front connection (Cu/Al)

IC @480 Vac, UL 489

IC @480 Vac, UL 489

Trip
Function

35kA
Product Number

List Price

65kA
Product Number

List Price

100kA
Product Number

List Price

LIT
LSIT
LIGT1
LSIGT1
LIT-CP2
LSIT-CP2
LIT
LSIT
LIGT1
LSIGT1
LIT-CP2
LSIT-CP2
LIT
LSIT
LIGT3
LSIGT3
LIT-CP4
LSIT-CP4

SGHH36BA0150
SGHH36BB0150
SGHH36BC0150
SGHH36BD0150
SGHH36BE0150
SGHH36BF0150
SGHH36BA0400
SGHH36BB0400
SGHH36BC0400
SGHH36BD0400
SGHH36BE0400
SGHH36BF0400
SGHH36BA0600
SGHH36BB0600
SGHH36BC0600
SGHH36BD0600
SGHH36BE0600
SGHH36BF0600

$4774.00
$6139.00
$5984.00
$7349.00
$5074.00
$6439.00
$4774.00
$6139.00
$5984.00
$7349.00
$5074.00
$6439.00
$5771.00
$7136.00
$6981.00
$8346.00
$6071.00
$7436.00

SGLL36BA0150
SGLL36BB0150
SGLL36BC0150
SGLL36BD0150
SGLL36BE0150
SGLL36BF0150
SGLL36BA0400
SGLL36BB0400
SGLL36BC0400
SGLL36BD0400
SGLL36BE0400
SGLL36BF0400
SGLL36BA0600
SGLL36BB0600
SGLL36BC0600
SGLL36BD0600
SGLL36BE0600
SGLL36BF0600

$5919.00
$7284.00
$7129.00
$8494.00
$6219.00
$7584.00
$5919.00
$7284.00
$7129.00
$8494.00
$6219.00
$7584.00
$7155.00
$8520.00
$8365.00
$9730.00
$7455.00
$8820.00

SGPP36BA0150
SGPP36BB0150
SGPP36BC0150
SGPP36BD0150
SGPP36BE0150
SGPP36BF0150
SGPP36BA0400
SGPP36BB0400
SGPP36BC0400
SGPP36BD0400
SGPP36BE0400
SGPP36BF0400
SGPP36BA0600
SGPP36BB0600
SGPP36BC0600
SGPP36BD0600
SGPP36BE0600
SGPP36BF0600

$6412.00
$7777.00
$7622.00
$8987.00
$6712.00
$8077.00
$6412.00
$7777.00
$7622.00
$8987.00
$6712.00
$8077.00
$7644.00
$9009.00
$8854.00
$10219.00
$7944.00
$9309.00

Product Number

3-Pole
lug kit
TCLK3653

List Price

Wire Range

$42.00

(2) 2/0-500 Al
or
(1) 6-600 Al

(2) 2/0-500 Cu
or
(1) 8-600 Cu

1For grounded neutral systems (1**/3w or 3**4w) a neutral current sensor is required. Refer to page 3-109.
2For +24 Vdc Control Power Accessories refer to pages 3-106 to 3-109.
3Order one kit for either line or load end; two kits required for both.
4100% UL rated supplied with back-connected assembly which increases breaker depth. Refer to outline drawing for details.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-59
Prices and data subject to change without notice

MOLDED CASE
CIRCUIT BREAKERS

IC @480 Vac, UL 489

GO-135S

3

Molded Case Circuit Breakers

Industrial Circuit Breakers
60-600A Circuit Breakers
Electronic Trip
Spectra RMS
with MicroVersaTrip PM Trip Units 1
MicroVersaTrip PM, Standard UL Rated (No Protective Relays)
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max.
Frame
IC @480 Vac, UL 489
Current
Sensor

150

400

600

Terminal Lugs for Front connection (Cu/Al)

IC @480 Vac, UL 489

IC @480 Vac, UL 489

Trip
Function

35kA
Product Number

List Price,
GO-135PM

65kA
Product Number

List Price,
GO-135PM

100kA
Product Number

List Price,
GO-135PM

LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2

SGHB36CA0150
SGHB36CB0150
SGHB36CC0150
SGHB36CD0150
SGHB36CA0400
SGHB36CB0400
SGHB36CC0400
SGHB36CD0400
SGHB36CA0600
SGHB36CB0600
SGHB36CC0600
SGHB36CD0600

$3797.00
$5162.00
$5007.00
$6372.00
$3797.00
$5162.00
$5007.00
$6372.00
$4751.00
$6116.00
$5961.00
$7326.00

SGLB36CA0150
SGLB36CB0150
SGLB36CC0150
SGLB36CD0150
SGLB36CA0400
SGLB36CB0400
SGLB36CC0400
SGLB36CD0400
SGLB36CA0600
SGLB36CB0600
SGLB36CC0600
SGLB36CD0600

$4952.00
$6317.00
$6162.00
$7527.00
$4952.00
$6317.00
$6162.00
$7527.00
$5705.00
$7070.00
$6915.00
$8280.00

SGPB36CA0150
SGPB36CB0150
SGPB36CC0150
SGPB36CD0150
SGPB36CA0400
SGPB36CB0400
SGPB36CC0400
SGPB36CD0400
SGPB36CA0600
SGPB36CB0600
SGPB36CC0600
SGPB36CD0600

$6132.00
$7497.00
$7342.00
$8707.00
$6132.00
$7497.00
$7342.00
$8707.00
$7080.00
$8445.00
$8290.00
$9655.00

Product Number

List Price,
GO-135S

Wire Range
(2) 2/0-500 Cu
or
(1) 8-600 Cu

3-Pole
lug kit
TCLK3653

$42.00
(2) 2/0-500 Al
or
(1) 6-600 Al

MicroVersaTrip PM, 100% UL Rated 4 (No Protective Relays)
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max.
Frame
IC @480 Vac, UL 489
Current
Sensor

MOLDED CASE
CIRCUIT BREAKERS

150

3

400

600

Trip
Function

35kA
Product Number

List Price,
GO-135PM

65kA
Product Number

LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2

SGHH36CA0150
SGHH36CB0150
SGHH36CC0150
SGHH36CD0150
SGHH36CA0400
SGHH36CB0400
SGHH36CC0400
SGHH36CD0400
SGHH36CA0600
SGHH36CB0600
SGHH36CC0600
SGHH36CD0600

$5974.00
$7339.00
$7184.00
$8549.00
$5974.00
$7339.00
$7184.00
$8549.00
$6971.00
$8336.00
$8181.00
$9546.00

SGLL36CA0150
SGLL36CB0150
SGLL36CC0150
SGLL36CD0150
SGLL36CA0400
SGLL36CB0400
SGLL36CC0400
SGLL36CD0400
SGLL36CA0600
SGLL36CB0600
SGLL36CC0600
SGLL36CD0600

MicroVersaTrip Plus and PM Rating Plug Selection —
All Plugs List Price, $106.00
Circuit Breaker
Frame

Sensor
Rating

Rating Plug
Rating (Amperes)

150

60
80
100
125
150
150
200
225
250
300
350
400
300
400
450
500
600

400
SGHB, SGHH, SGLB,
SGLL, SGPB, SGPP

600

Terminal Lugs for Front connection (Cu/Al)

IC @480 Vac, UL 489

IC @480 Vac, UL 489

List Price,
GO-135PM
$7119.00
$8484.00
$8329.00
$9694.00
$7119.00
$8484.00
$8329.00
$9694.00
$8355.00
$9720.00
$9565.00
$10930.00

100kA
Product Number

List Price,
GO-135PM

SGPP36CA0150
SGPP36CB0150
SGPP36CC0150
SGPP36CD0150
SGPP36CA0400
SGPP36CB0400
SGPP36CC0400
SGPP36CD0400
SGPP36CA0600
SGPP36CB0600
SGPP36CC0600
SGPP36CD0600

$7612.00
$8977.00
$8822.00
$10187.00
$7612.00
$8977.00
$8822.00
$10187.00
$8844.00
$10209.00
$10054.00
$11419.00

Product Number

List Price,
GO-135S

Wire Range
(2) 2/0-500 Cu
or
(1) 8-600 Cu

3-Pole
lug kit
TCLK3653

$42.00
(2) 2/0-500 Al
or
(1) 6-600 Al

GO-135S
Rating Plug
Product No.
SRPG150B60
SRPG150B80
SRPG150B100
SRPG150B125
SRPG150B150
SRPG400B150
SRPG400B200
SRPG400B225
SRPG400B250
SRPG400B300
SRPG400B350
SRPG400B400
SRPG600B300
SRPG600B400
SRPG600B450
SRPG600B500
SRPG600B600

1MicroVersaTrip PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages 3-106 to 3-109.
2For grounded neutral systems (1**/3w or 3**4w) a neutral current sensor is required. Refer to page 3-109.
3Order one kit for either line or load end; two kits required for both.
4100% UL rated supplied with back-connected assembly which increases breaker depth. Refer to outline drawing for details.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-60
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
60-600A Circuit Breakers
Electronic Trip
Spectra RMS
with MicroVersaTrip PM Trip Units 1
MicroVersaTrip PM, Standard UL Rated (With Protective Relaying)
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max.
Frame
IC @480 Vac, UL 489
Current
Sensor

150

400

600

Terminal Lugs for Front connection (Cu/Al)

IC @480 Vac, UL 489

IC @480 Vac, UL 489

Trip
Function

35kA
Product Number

List Price,
GO-135PM

65kA
Product Number

List Price,
GO-135PM

100kA
Product Number

List Price,
GO-135PM

LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2

SGHB36DA0150
SGHB36DB0150
SGHB36DC0150
SGHB36DD0150
SGHB36DA0400
SGHB36DB0400
SGHB36DC0400
SGHB36DD0400
SGHB36DA0600
SGHB36DB0600
SGHB36DC0600
SGHB36DD0600

$4997.00
$6362.00
$6207.00
$7572.00
$4997.00
$6362.00
$6207.00
$7572.00
$5951.00
$7316.00
$7161.00
$8526.00

SGLB36DA0150
SGLB36DB0150
SGLB36DC0150
SGLB36DD0150
SGLB36DA0400
SGLB36DB0400
SGLB36DC0400
SGLB36DD0400
SGLB36DA0600
SGLB36DB0600
SGLB36DC0600
SGLB36DD0600

$6152.00
$7517.00
$7362.00
$8727.00
$6152.00
$7517.00
$7362.00
$8727.00
$6905.00
$8270.00
$8115.00
$9480.00

SGPB36DA0150
SGPB36DB0150
SGPB36DC0150
SGPB36DD0150
SGPB36DA0400
SGPB36DB0400
SGPB36DC0400
SGPB36DD0400
SGPB36DA0600
SGPB36DB0600
SGPB36DC0600
SGPB36DD0600

$7332.00
$8697.00
$8542.00
$9907.00
$7332.00
$8697.00
$8542.00
$9907.00
$8280.00
$9645.00
$9490.00
$10855.00

Product Number

List Price,
GO-135S

Wire Range
(2) 2/0-500 Cu
or
(1) 8-600 Cu

3-Pole
lug kit
TCLK3653

$42.00
(2) 2/0-500 Al
or
(1)6-600 Al

MicroVersaTrip PM, 100% UL Rated 4 (With Protective Relays)
SG600 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
SGL, SGP UL Current Limiting; 3-Pole, UL/CSA: 600 Vac Max., IEC 947-2: 630A, 690 Vac Max.
Frame

Current
Sensor

150

400

600

Trip
Function

35kA
Product Number

List Price,
GO-135PM

65kA
Product Number

LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2

SGHH36DA0150
SGHH36DB0150
SGHH36DC0150
SGHH36DD0150
SGHH36DA0400
SGHH36DB0400
SGHH36DC0400
SGHH36DD0400
SGHH36DA0600
SGHH36DB0600
SGHH36DC0600
SGHH36DD0600

$7174.00
$8539.00
$8384.00
$9749.00
$7174.00
$8539.00
$8384.00
$9749.00
$8171.00
$9536.00
$9381.00
$10746.00

SGLL36DA0150
SGLL36DB0150
SGLL36DC0150
SGLL36DD0150
SGLL36DA0400
SGLL36DB0400
SGLL36DC0400
SGLL36DD0400
SGLL36DA0600
SGLL36DB0600
SGLL36DC0600
SGLL36DD0600

MicroVersaTrip Plus and PM Rating Plug Selection —
All Plugs List Price, $106.00
Circuit Breaker
Frame

Sensor
Rating

Rating Plug
Rating (Amperes)

150

60
80
100
125
150
150
200
225
250
300
350
400
300
400
450
500
600

400
SGHB, SGHH, SGLB,
SGLL, SGPB, SGPP

600

Terminal Lugs for Front connection (Cu/Al)

IC @480 Vac, UL 489
List Price,
GO-135PM
$8319.00
$9684.00
$9529.00
$10894.00
$8319.00
$9684.00
$9529.00
$10894.00
$9555.00
$10920.00
$10765.00
$12130.00

IC @480 Vac, UL 489
100kA
Product Number

List Price,
GO-135PM

SGPP36DA0150
SGPP36DB0150
SGPP36DC0150
SGPP36DD0150
SGPP36DA0400
SGPP36DB0400
SGPP36DC0400
SGPP36DD0400
SGPP36DA0600
SGPP36DB0600
SGPP36DC0600
SGPP36DD0600

$8812.00
$10177.00
$10022.00
$11387.00
$8812.00
$10177.00
$10022.00
$11387.00
$10044.00
$11409.00
$11254.00
$12619.00

Product Number

List Price,
GO-135S

Wire Range
(2) 2/0-500 Cu
or
(1) 6-600 Cu

3-Pole
lug kit
TCLK3653

$42.00
(2) 2/0-500 Al
or
(1) 8-600 Al

GO-135S
Rating Plug
Product No.

3

SRPG150B60
SRPG150B80
SRPG150B100
SRPG150B125
SRPG150B150
SRPG400B150
SRPG400B200
SRPG400B225
SRPG400B250
SRPG400B300
SRPG400B350
SRPG400B400
SRPG600B300
SRPG600B400
SRPG600B450
SRPG600B500
SRPG600B600

1MicroVersaTrip PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages 3-106 to 3-109.
2For grounded neutral systems (1**/3w or 3**4w) a neutral current sensor is required. Refer to page 3-109.
3Order one kit for either line or load end; two kits required for both.
4100% UL rated supplied with back-connected assembly which increases breaker depth. Refer to outline drawing for details.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

MOLDED CASE
CIRCUIT BREAKERS

IC @480 Vac, UL 489

www.geelectrical.com

BuyLog Catalog

3-61
Prices and data subject to change without notice

Molded Case Circuit Breakers

Industrial Circuit Breakers
125-600A Circuit Breakers
Thermal-Magnetic Trip
J600 Line Circuit Breakers
Types TJJ, TJK, THJK

TYPE TJK

Type TJJ Noninterchangeable Trip (includes Line and Load Lugs), suitable for reverse feed

GO-135B

Frame

Ampere
Rating
125
150
175
200
225
250
300
350
400

2-Pole, 400 Ampere Frame
600 Vac, 250 Vdc

Adjustable Instantaneous
Trip Ampere Range

3-Pole, 400 Ampere Frame
600 Vac

Low

High

Product
Number

List
Price

Product
Number

List
Price

375
450
525
600
675
750
900
1050
1200

1250
1500
1750
2000
2250
2500
3000
3500
4000

TJJ426125WL
TJJ426150WL
TJJ426175WL
TJJ426200WL
TJJ426225WL
TJJ426250WL
TJJ426300WL
TJJ426350WL
TJJ426400WL

$2118.00
$2118.00
$2118.00
$2118.00
$2118.00
$2118.00
$2118.00
$2118.00
$2118.00

TJJ436125WL
TJJ436150WL
TJJ436175WL
TJJ436200WL
TJJ436225WL
TJJ436250WL
TJJ436300WL
TJJ436350WL
TJJ436400WL

$2573.00
$2573.00
$2573.00
$2573.00
$2573.00
$2573.00
$2573.00
$2573.00
$2573.00

Terminal Lugs for Front
Connection (Cu/Al)
Copper/
Aluminum Lugs

Wire
Size

TCAL432
Included in
price of
breaker

(1) 6-600 or
(2) 2/0-250 Cu/Al

Types TJK, THJK — Interchangeable Trip, not suitable for reverse feed

GO-135B

MOLDED CASE
CIRCUIT BREAKERS

Complete Circuit Breaker
Includes Line and Load Lugs

3

Adjustable Instantaneous
Ampere Trip Ampere Range Standard
Rating Low
High
Product Number

List
Price

400A Frame—Two-Pole
125
375 1250 TJK426125WL
150
450 1500 TJK426150WL
175
525 1750 TJK426175WL
200
600 2000 TJK426200WL
225
675 2250 TJK426225WL
250
750 2500 TJK426250WL
300
900 3000 TJK426300WL
350
1050 3500 TJK426350WL
400
1200 4000 TJK426400WL

$2118.00
$2118.00
$2118.00
$2118.00
$2118.00
$2118.00
$2118.00
$2118.00
$2118.00

THJK426125WL
THJK426150WL
THJK426175WL
THJK426200WL
THJK426225WL
THJK426250WL
THJK426300WL
THJK426350WL
THJK426400WL

$3085.00
$3085.00
$3085.00
$3085.00
$3085.00
$3085.00
$3085.00
$3085.00
$3085.00

400A Frame—Three-Pole
125
375 1250 TJK436125WL
150
450 1500 TJK436150WL
175
525 1750 TJK436175WL
200
600 2000 TJK436200WL
225
675 2250 TJK436225WL
250
750 2500 TJK436250WL
300
900 3000 TJK436300WL
350
1050 3500 TJK436350WL
400
1200 4000 TJK436400WL
400
600 2000
—
Mag
1200 4000
—
Only
350 1000
—

$2573.00
$2573.00
$2573.00
$2573.00
$2573.00
$2573.00
$2573.00
$2573.00
$2573.00
—
—
—

THJK436125WL
THJK436150WL
THJK436175WL
THJK436200WL
THJK436225WL
THJK436250WL
THJK436300WL
THJK436350WL
THJK436400WL
—
—
—

$3675.00
$3675.00
$3675.00
$3675.00
$3675.00
$3675.00
$3675.00
$3675.00
$3675.00
—
—
—

Hi-Break
Product Number

List
Price

Terminal Lugs for Front
Connection (Cu/Al)1
Frame Only
Product Number

List
Price

TJK426F000 $1598.00
Standard
Frame

THJK426F000 $2565.00
Hi-Break

TJK436F000 $2025.00
Standard
Frame

THJK436F000 $3127.00
Hi-Break

Trip Unit Only. Use
with Standard and
Hi-Break Frames

List
Price

TJK426T125
TJK426T150
TJK426T175
TJK426T200
TJK426T225
TJK426T250
TJK426T300
TJK426T350
TJK426T400

$464.00
$464.00
$464.00
$464.00
$464.00
$464.00
$464.00
$464.00
$464.00

TJK436T125
TJK436T150
TJK436T175
TJK436T200
TJK436T225
TJK436T250
TJK436T300
TJK436T350
TJK436T400
TJK436TM14003
TJK436TM24003
TJK436TM34003

$464.00
$464.00
$464.00
$464.00
$464.00
$464.00
$464.00
$464.00
$464.00
$558.00
$558.00
$558.00

Product Number
(Order 2
per pole)

List
Price

TCAL432

$14.00

(1) 6-600
or
(2) 2/0-250 Cu/Al

TCAL432

$14.00

(1) 6-600
or
(2) 2/0-250 Cu/Al

Wire Size

1For optional lugs, see page 3-101.
2Not UL listed.
3Alternate lug for 750 kcmil Cu/Al cable, Product Number TCAL47 List Price $26.00, GO-135B.

Accessories: See pages 3-85 to 3-104.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-62
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
125-600A Circuit Breakers
Thermal-Magnetic Trip
J600 Line Circuit Breakers
Types TJJ, TJK, THJK

Types TJK, THJK — Interchangeable Trip

GO-135S
Complete Circuit Breaker
Includes Line and Load Lugs

Adjustable Instantaneous
Ampere Trip Ampere Range Standard
Rating Low
High
Product Number

List
Price

600A Frame—Two-Pole
250
750 2500 TJK626250WL
300
900 3000 TJK626300WL
350
1050 3500 TJK626350WL
400
1200 4000 TJK626400WL
450
1350 4500 TJK626450WL
500
1500 5000 TJK626500WL
600
1800 6000 TJK626600WL

$2812.00
$2812.00
$2812.00
$2812.00
$2848.00
$2848.00
$2848.00

THJK626250WL
THJK626300WL
THJK626350WL
THJK626400WL
THJK626450WL
THJK626500WL
THJK626600WL

$3704.00
$3704.00
$3704.00
$3704.00
$3740.00
$3740.00
$3740.00

$3539.00
$3539.00
$3539.00
$3539.00
$3593.00
$3593.00
$3593.00
—

THJK636250WL
THJK636300WL
THJK636350WL
THJK636400WL
THJK636450WL
THJK636500WL
THJK636600WL
—

$4457.00
$4457.00
$4457.00
$4457.00
$4511.00
$4511.00
$4511.00
—

600A Frame—Three-Pole
250
750 2500 TJK636250WL
300
900 3000 TJK636300WL
350
1050 3500 TJK636350WL
400
1200 4000 TJK636400WL
450
1350 4500 TJK636450WL
500
1500 5000 TJK636500WL
600
1800 600
TJK636600WL
600
6000 2000
—
Mag
Only
1800 6000
—

—

Hi-Break
Product Number

—

List
Price

Terminal Lugs for Front
Connection (Cu/Al)1
Frame Only
Product Number

List
Price

TJK626F000 $1535.00
Standard
Frame
THJK626F000
Hi-Break
$2427.00
Frame

TJK636F000 $2234.00
Standard
Frame
THJK636F000
Hi-Break
$3152.00
Frame

Trip Unit Only. Use
with Standard and
Hi-Break Frames

List
Price

Product Number
(Order 2
per pole)

List
Price

TJK626T250
TJK626T300
TJK626T350
TJK626T400
TJK626T450
TJK626T500
TJK626T600

$1221.00
$1221.00
$1221.00
$1221.00
$1221.00
$1221.00
$1221.00

TCAL432

$14.00

TCAL63

$23.00

TJK636T250
TJK636T300
TJK636T350
TJK636T400
TJK636T450
TJK636T500
TJK636T600
TJK636TM16003

$1221.00
$1221.00
$1221.00
$1221.00
$1221.00
$1221.00
$1221.00
$1465.00

TCAL432

$14.00

TCAL63

$23.00

Wire Size
(1) 6-600
or
(2) 2/0-250 Cu/Al
(2) 4/0-350 Cu
or
(2) 300-500 Al

(1) 6-600
or
(2) 2/0-250 Cu/Al
(2) 4/0-350 Cu
or
(2) 300-500 Al

TJK636TM26003 $1465.00

—

1For optional lugs, see page 3-101.
2Alternate lug for 750 kcmil Cu/Al cable, Product Number TCAL47 List Price $26.00, GO-135B.
3Not UL listed.

MOLDED CASE
CIRCUIT BREAKERS

Accessories: See pages 3-85 to 3-104.

3

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-63
Prices and data subject to change without notice

Molded Case Circuit Breakers

Industrial Circuit Breakers
300-1200A Circuit Breakers
Electronic Trip
Spectra RMS

SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
UL/CSA: 800A, 600 Vac Max., IEC 947-2:800A 690 Vac Max.
Rating Plug

GO-135S

Frame
UL 489 IC @480 Vac

Adjustable
Instantaneous
Trip
Ampere Range
Ampere
Rating Low
High
300
400
500
600
700
800

940
1255
1570
1875
2155
2440

3015
4015
5020
6195
7420
8705

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

50kA
Product
Number

List
Price

Current
Sensor

SRPK800A300
SRPK800A400
SRPK800A500
SRPK800A600
SRPK800A700
SRPK800A800

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

800

65kA

Poles

Product
Number

List
Price

Product
Number

List
Price

2

SKHA26AT0800

$3377.00

SKLA26AT0800

$4301.00

3

SKHA36AT0800

$4323.00

SKLA36AT0800

Product
Number

List
Price

TCAL81

$47.00

(3) 3/0-500 Cu

$5234.00

(3) 3/0-500 Al

SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
UL/CSA: 800A, 600 Vac Max., IEC 947-2:800A 690 Vac Max.
Rating Plug

Wire
Range

GO-135S

Frame

Terminal Lugs for Front Connection (Cu/Al)

UL 489 IC @480 Vac
Adjustable
Instantaneous
Ampere Trip Ampere Range
Rating Low
High

MOLDED CASE
CIRCUIT BREAKERS

300
400
500
600
700
800

3

940
1255
1570
1875
2155
2440

3015
4015
5020
6195
7420
8705

100kA
Product
Number

List
Price

Current
Sensor

SRPK800A300
SRPK800A400
SRPK800A500
SRPK800A600
SRPK800A700
SRPK800A800

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

800

Poles

Product
Number

List
Price

2

SKPA26AT0800

$6746.00

3

SKPA36AT0800

Product
Number

List
Price

TCAL81

$47.00

(3) 3/0-500 Cu

$8240.00

(3) 3/0-500 Al

SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max.
Rating Plug

GO-135S

Frame
UL 489 IC @480 Vac

Adjustable
Instantaneous
Trip
Ampere Range
Ampere
Rating Low
High
600
700
800
1000
1200

1825
2125
2430
3040
3650

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

35kA
Product
Number

List
Price

6110
SRPK1200A600 $106.00
7125 SRPK1200A700 $106.00
8145 SRPK1200A800 $106.00
10180 SRPK1200A1000 $106.00
12215 SRPK1200A1200 $106.00

Current
Sensor

65kA

Poles

Product
Number

List
Price

Product
Number

List
Price

2

SKHA26AT1200

$7057.00

SKLA26AT1200

$7958.00

1200
3

SKHA36AT1200

$7679.00

SKLA36AT1200

Product
Number

List
Price

TCAL125

$76.00

Wire
Range
(4) 250-500 Cu1

$8586.00

(4) 250-350 Al

SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max.
Rating Plug

Wire
Range

GO-135S

Frame

Terminal Lugs for Front Connection (Cu/Al)

UL 489 IC @480 Vac
Adjustable
Instantaneous
Trip
Ampere Range
Ampere
Rating Low
High
600
700
800
1000
1200

1825
2125
2430
3040
3650

100kA
Product
Number

List
Price

6110
SRPK1200A600 $106.00
7125 SRPK1200A700 $106.00
8145 SRPK1200A800 $106.00
10180 SRPK1200A1000 $106.00
12215 SRPK1200A1200 $106.00

Current
Sensor

Poles

Product
Number

List
Price

2

SKPA26AT1200

$10136.00

1200
3

SKPA36AT1200

Product
Number

List
Price

TCAL125

$76.00

Wire
Range
(4) 250-500 Cu1

$11183.00

(4) 250-350 Al

1Suitable for 500 kcmil copper for voltage drop consideration, 1200 ampere max. rating.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-64
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
300-1200A Circuit Breakers
Electronic Trip
Spectra RMS

SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
100% UL Rated, 3-Pole: 800A, 600 Vac Max.; IEC 947-2: 800A, 690 Vac Max.
Rating Plug

Frame
UL 489 IC @480 Vac

Adjustable
Instantaneous
Trip
Ampere Range
Ampere
Rating Low
High
300
400
500
600
700
800

940
1255
1570
1875
2155
2440

3015
4015
5020
6195
7420
8705

GO-135S
Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

50kA
Product
Number

List
Price

SRPK800A300
SRPK800A400
SRPK800A500
SRPK800A600
SRPK800A700
SRPK800A800

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

800

65kA

Poles

Product
Number

List
Price

Product
Number

List
Price

Product
Number

List
Price

3

SKHH36AT0800

$7514.00

SKLL36AT0800

$9325.00

TCAL81

$47.00

Wire
Range
(3) 3/0-500 Cu

(3) 3/0-500 Al

SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
100% UL Rated, 3-Pole: 800A, 600 Vac Max.; IEC 947-2: 800A, 690 Vac Max.
Rating Plug

GO-135S

Frame

Terminal Lugs for Front Connection (Cu/Al)

UL 489 IC @480 Vac

300
400
500
600
700
800

940
1255
1570
1875
2155
2440

3015
4015
5020
6195
7420
8705

100kA
Product
Number

List
Price

SRPK800A300
SRPK800A400
SRPK800A500
SRPK800A600
SRPK800A700
SRPK800A800

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

800

Poles

Product
Number

List
Price

Product
Number

List
Price

3

SKPP36AT0800

$10712.00

TCAL81

$47.00

(3) 3/0-500 Cu

(3) 3/0-500 Al

SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
100% UL Rated, 3-Pole: 1200A, 600 Vac Max.; IEC 947-2: 1000A, 690 Vac Max.
Rating Plug

600
700
800
1000
1200

1825
2125
2430
3040
3650

GO-135S

Frame
UL 489 IC @480 Vac

Adjustable
Instantaneous
Ampere Trip Ampere Range
Rating Low
High

Terminal Lugs for Front Connection (Cu/Al)
UL 489 IC @480 Vac

50kA
Product
Number

List
Price

6110
SRPK1200A600 $106.00
7125 SRPK1200A700 $106.00
8145 SRPK1200A800 $106.00
10180 SRPK1200A1000 $106.00
12215 SRPK1200A1200 $106.00

Wire
Range

Current
Sensor

1200

65kA

Poles

Product
Number

List
Price

Product
Number

List
Price

Product
Number

List
Price

3

SKHH36AT1000

$11051.00

SKLL36AT1000

$13678.00

TCAL125

$76.00

3

SKHH36AT12001

$11450.00

SKLL36AT12001

$14250.00

Wire
Range
(4) 250-500 Cu2
(4) 250-350 Al

3

SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
100% UL Rated, 3-Pole: 1200A, 600 Vac Max.; IEC 947-2: 1000A, 690 Vac Max.
Rating Plug

GO-135S

Frame

Terminal Lugs for Front Connection (Cu/Al)

UL 489 IC @480 Vac
Adjustable
Instantaneous
Trip
Ampere Range
Ampere
Rating Low
High
600
700
800
1000
1200

1825
2125
2430
3040
3650

100kA
Product
Number

List
Price

6110
SRPK1200A600 $106.00
7125 SRPK1200A700 $106.00
8145 SRPK1200A800 $106.00
10180 SRPK1200A1000 $106.00
12215 SRPK1200A1200 $106.00

Current
Sensor

1200

Poles

Product
Number

List
Price

Product
Number

List
Price

3

SKPP36AT1000

$14538.00

TCAL125

$76.00

3

SKPP36AT12001

$15235.00

Wire
Range
(4) 250-500 Cu2
(4) 250-350 Al

1100% UL rated SK1200 supplied with back-connected assembly which increases breaker depth. Refer to outline drawings for details.
2Suitable for 500 kcmil copper for voltage drop consideration, 1200A max. rating.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

MOLDED CASE
CIRCUIT BREAKERS

Adjustable
Instantaneous
Trip
Ampere Range
Ampere
Rating Low
High

www.geelectrical.com

BuyLog Catalog

3-65
Prices and data subject to change without notice

Molded Case Circuit Breakers

Industrial Circuit Breakers
300-1200A Circuit Breakers
Electronic Trip
Spectra RMS
SK1200 with MicroVersaTrip Plus and PM
MicroVersaTrip Plus, Standard UL Rated
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
3-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only)

GO-135S

Frame
IC @480 Vac, UL 489
Current
Sensor

800

1200

Trip
Function

50kA
Product Number

LIT
LSIT
LIGT1
LSIGT1
LIT-CP2
LSIT-CP2
LIT
LSIT
LIGT1
LSIGT1
LIT-CP2
LSIT-CP2

SKHB36BA0800
SKHB36BB0800
SKHB36BC0800
SKHB36BD0800
SKHB36BE0800
SKHB36BF0800
SKHB36BA1200
SKHB36BB1200
SKHB36BC1200
SKHB36BD1200
SKHB36BE1200
SKHB36BF1200

Terminal Lugs for Front connection (Cu/Al)

IC @480 Vac, UL 489

IC @480 Vac, UL 489

List Price

65kA
Product Number

List Price

$4588.00
$5953.00
$5798.00
$7163.00
$4888.00
$6253.00
$8077.00
$9442.00
$9287.00
$10652.00
$8377.00
$9742.00

SKLB36BA0800
SKLB36BB0800
SKLB36BC0800
SKLB36BD0800
SKLB36BE0800
SKLB36BF0800
SKLB36BA1200
SKLB36BB1200
SKLB36BC1200
SKLB36BD1200
SKLB36BE1200
SKLB36BF1200

$5552.00
$6917.00
$6762.00
$8127.00
$5852.00
$7217.00
$9048.00
$10413.00
$10258.00
$11623.00
$9348.00
$10713.00

100kA
Product Number
SKPB36BA0800
SKPB36BB0800
SKPB36BC0800
SKPB36BD0800
SKPB36BE0800
SKPB36BF0800
SKPB36BA1200
SKPB36BB1200
SKPB36BC1200
SKPB36BD1200
SKPB36BE1200
SKPB36BF1200

List Price
$8734.00
$10099.00
$9944.00
$11309.00
$9034.00
$10399.00
$11854.00
$13219.00
$13064.00
$14429.00
$12154.00
$13519.00

Product Number

List Price

Wire Range

TCAL81

$47.00

(3) 3/0-500 Cu
(3) 3/0-500 Al

TCAL125

$76.00

(4) 250-350 Cu3
(4) 250-500 Al

MicroVersaTrip Plus, 100% UL Rated 4
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
3-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only)

GO-135S

Frame
IC @480 Vac, UL 489
Current
Sensor

MOLDED CASE
CIRCUIT BREAKERS

800

3

1200

12004

Trip
Function

50kA
Product Number

LIT
LSIT
LIGT1
LSIGT1
LIT-CP2
LSIT-CP2
LIT
LSIT
LIGT1
LSIGT1
LIT-CP2
LSIT-CP2
LIT
LSIT
LIGT1
LSIGT1
LIT-CP2
LSIT-CP2

SKHH36BA0800
SKHH36BB0800
SKHH36BC0800
SKHH36BD0800
SKHH36BE0800
SKHH36BF0800
SKHH36BA1000
SKHH36BB1000
SKHH36BC1000
SKHH36BD1000
SKHH36BE1000
SKHH36BF1000
SKHH36BA1200
SKHH36BB1200
SKHH36BC1200
SKHH36BD1200
SKHH36BE1200
SKHH36BF1200

Terminal Lugs for Front connection (Cu/Al)

IC @480 Vac, UL 489

IC @480 Vac, UL 489

List Price

65kA
Product Number

List Price

$7975.00
$9340.00
$9185.00
$10550.00
$8275.00
$9640.00
$11624.00
$12989.00
$12834.00
$14199.00
$11924.00
$13289.00
$11624.00
$12989.00
$12834.00
$14199.00
$11924.00
$13289.00

SKLL36BA0800
SKLL36BB0800
SKLL36BC0800
SKLL36BD0800
SKLL36BE0800
SKLL36BF0800
SKLL36BA1000
SKLL36BB1000
SKLL36BC1000
SKLL36BD1000
SKLL36BE1000
SKLL36BF1000
SKLL36BA1200
SKLL36BB1200
SKLL36BC1200
SKLL36BD1200
SKLL36BE1200
SKLL36BF1200

$9892.00
$11257.00
$11102.00
$12467.00
$10192.00
$11557.00
$14414.00
$15779.00
$15624.00
$16989.00
$14714.00
$16079.00
$14414.00
$15779.00
$15624.00
$16989.00
$14714.00
$16079.00

MicroVersaTrip Plus and PM Rating Plug Selection —
All Plugs List Price, $106.00

800
SKHB, SKHH, SKLB,
SKLL, SKPB, SKPP

1200

300
400
500
600
700
800
600
700
800
1000
1200

100kA
Product Number
SKPP36BA0800
SKPP36BB0800
SKPP36BC0800
SKPP36BD0800
SKPP36BE0800
SKPP36BF0800
SKPP36BA1000
SKPP36BB1000
SKPP36BC1000
SKPP36BD1000
SKPP36BE1000
SKPP36BF1000
SKPP36BA1200
SKPP36BB1200
SKPP36BC1200
SKPP36BD1200
SKPP36BE1200
SKPP36BF1200

List Price
$11354.00
$12719.00
$12564.00
$13929.00
$11654.00
$13019.00
$15410.00
$16775.00
$16620.00
$17985.00
$15710.00
$17075.00
$15410.00
$16775.00
$16620.00
$17985.00
$15710.00
$17075.00

Product Number

List Price

Wire Range

TCAL81

$47.00

(3) 3/0-500 Cu
(3) 3/0-500 Al

TCAL125

$76.00

(4) 250-350 Cu3
(4) 250-500 Al

GO-135S
SRPK800B300
SRPK800B400
SRPK800B500
SRPK800B600
SRPK800B700
SRPK800B800
SRPK1200B600
SRPK1200B700
SRPK1200B800
SRPK1200B1000
SRPK1200B12006

1For grounded neutral systems (1**/3w or 3**4w) a neutral current sensor is required. Refer to page 3-109.
2For +24 Vdc Control Power Accessories refer to pages 3-106 to 3-109.
3Suitable for 500 kcmil copper, 1200A max. rating.
4100% UL rated SK1200 supplied with back-connected assembly which increases breaker depth. Refer to outline drawing 168D1678 Sh2 for details.
5For ground fault neutral current sensor, use 1200A rating.
6Not suitable for use with 100% rated, 1000A breaker frame.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-66
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
300-1200A Circuit Breakers
Electronic Trip
Spectra RMS
SK1200 with MicroVersaTrip PM 1

MicroVersaTrip PM, Standard UL Rated (No Protective Relays)
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
3-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only)
Frame
IC @480 Vac, UL 489
Current
Sensor

800

1200

Terminal Lugs for Front connection (Cu/Al)

IC @480 Vac, UL 489

IC @480 Vac, UL 489

Trip
Function

50kA
Product Number

List Price,
GO-135PM

65kA
Product Number

List Price,
GO-135PM

100kA
Product Number

List Price,
GO-135PM

LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2

SKHB36CA0800
SKHB36CB0800
SKHB36CC0800
SKHB36CD0800
SKHB36CA1200
SKHB36CB1200
SKHB36CC1200
SKHB36CD1200

$5788.00
$7153.00
$6998.00
$8363.00
$9277.00
$10642.00
$10487.00
$11852.00

SKLB36CA0800
SKLB36CB0800
SKLB36CC0800
SKLB36CD0800
SKLB36CA1200
SKLB36CB1200
SKLB36CC1200
SKLB36CD1200

$6752.00
$8117.00
$7962.00
$9327.00
$10248.00
$11613.00
$11458.00
$12823.00

SKPB36CA0800
SKPB36CB0800
SKPB36CC0800
SKPB36CD0800
SKPB36CA1200
SKPB36CB1200
SKPB36CC1200
SKPB36CD1200

$9934.00
$11299.00
$11144.00
$12509.00
$13054.00
$14419.00
$14264.00
$15629.00

List Price,
GO-135S

Wire Range

TCAL81

$47.00

(3) 3/0-500 Cu
(3) 3/0-500 Al

TCAL125

$76.00

(4) 250-350 Cu3
(4) 250-500 Al

Product Number

MicroVersaTrip PM, 100% UL Rated (No Protective Relays)
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
3-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only)
Frame

Current
Sensor

800

12004

12005

Terminal Lugs for Front connection (Cu/Al)

IC @480 Vac, UL 489

IC @480 Vac, UL 489

Trip
Function

50kA
Product Number

List Price,
GO-135PM

65kA
Product Number

List Price,
GO-135PM

100kA
Product Number

List Price,
GO-135PM

LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2

SKHH36CA0800
SKHH36CB0800
SKHH36CC0800
SKHH36CD0800
SKHH36CA1000
SKHH36CB1000
SKHH36CC1000
SKHH36CD1000
SKHH36CA1200
SKHH36CB1200
SKHH36CC1200
SKHH36CD1200

$9175.00
$10540.00
$10385.00
$11750.00
$12824.00
$14189.00
$14034.00
$15399.00
$12824.00
$14189.00
$14034.00
$15399.00

SKLL36CA0800
SKLL36CB0800
SKLL36CC0800
SKLL36CD0800
SKLL36CA1000
SKLL36CB1000
SKLL36CC1000
SKLL36CD1000
SKLL36CA1200
SKLL36CB1200
SKLL36CC1200
SKLL36CD1200

$11092.00
$12457.00
$12302.00
$13667.00
$15614.00
$16979.00
$16824.00
$18189.00
$15614.00
$16979.00
$16824.00
$18189.00

SKPP36CA0800
SKPP36CB0800
SKPP36CC0800
SKPP36CD0800
SKPP36CA1000
SKPP36CB1000
SKPP36CC1000
SKPP36CD1000
SKPP36CA1200
SKPP36CB1200
SKPP36CC1200
SKPP36CD1200

$12554.00
$13919.00
$13764.00
$15129.00
$16610.00
$17975.00
$17820.00
$19185.00
$16610.00
$17975.00
$17820.00
$19185.00

MicroVersaTrip Plus and PM Rating Plug Selection —
All Plugs List Price, $106.00
300
400
500
600
700
800
600
700
800
1000
1200

800
SKHB, SKHH, SKLB,
SKLL, SKPB, SKPP

1200

List Price,
GO-135S

Wire Range

TCAL81

$47.00

(3) 3/0-500 Cu
(3) 3/0-500 Al

TCAL125

$76.00

Product Number

(4) 250-350Cu4
(4) 250-500 Al

3

GO-135S
SRPK800B300
SRPK800B400
SRPK800B500
SRPK800B600
SRPK800B700
SRPK800B800
SRPK1200B600
SRPK1200B700
SRPK1200B800
SRPK1200B1000
SRPK1200B12006

1MicroVersaTrip PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages 3-106 to 3-109.
2For grounded neutral systems (1**/3w or 3**4w) a neutral current sensor is required. Refer to page 3-109.
3Suitable for 500 kcmil copper, 1200A max. rating.
4For ground fault neutral current sensor, use 1200A rating.
5100% UL rated SK1200 supplied with back-connected assembly which increases breaker depth. Refer to outline drawing 168D1678 Sh2 for details.
6Not suitable for use with 100% rated, 1000A breaker frame.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

MOLDED CASE
CIRCUIT BREAKERS

IC @480 Vac, UL 489

BuyLog Catalog

3-67
Prices and data subject to change without notice

Molded Case Circuit Breakers

Industrial Circuit Breakers
300-1200A Circuit Breakers
Electronic Trip
Spectra RMS
SK1200 with MicroVersaTrip Plus and PM 1

MicroVersaTrip PM, Standard UL Rated (With Protective Relaying)
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
3-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only)
Frame
IC @480 Vac, UL 489
Current
Sensor

800

1200

Terminal Lugs for Front connection (Cu/Al)

IC @480 Vac, UL 489

IC @480 Vac, UL 489

Trip
Function

50kA
Product Number

List Price,
GO-135PM

65kA
Product Number

List Price,
GO-135PM

100kA
Product Number

List Price,
GO-135PM

LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2

SKHB36DA0800
SKHB36DB0800
SKHB36DC0800
SKHB36DD0800
SKHB36DA1200
SKHB36DB1200
SKHB36DC1200
SKHB36DD1200

$6988.00
$8353.00
$8198.00
$9563.00
$10477.00
$11842.00
$11687.00
$13052.00

SKLB36DA0800
SKLB36DB0800
SKLB36DC0800
SKLB36DD0800
SKLB36DA1200
SKLB36DB1200
SKLB36DC1200
SKLB36DD1200

$7952.00
$9317.00
$9162.00
$10527.00
$11448.00
$12813.00
$12658.00
$14023.00

SKPB36DA0800
SKPB36DB0800
SKPB36DC0800
SKPB36DD0800
SKPB36DA1200
SKPB36DB1200
SKPB36DC1200
SKPB36DD1200

$11134.00
$12499.00
$12344.00
$13709.00
$14254.00
$15619.00
$15464.00
$16829.00

List Price,
GO-135S

Wire Range

TCAL81

$47.00

(3) 3/0-500 Cu
(3) 3/0-500 Al

TCAL125

$76.00

(4) 250-350 Cu3
(4) 250-500 Al

Product Number

MicroVersaTrip PM, 100% UL Rated (With Protective Relays)
SK1200 Line, Suitable for Reverse Feed, UL File E-11592, CSA LR 40350
3-Pole, UL/CSA: 1200A, 600 Vac Max., IEC 947-2: 1250A, 690 Vac Max. (SKL, SKP only)
Frame
IC @480 Vac, UL 489
Current
Sensor

MOLDED CASE
CIRCUIT BREAKERS

800

3

12004

12005

Terminal Lugs for Front connection (Cu/Al)

IC @480 Vac, UL 489

IC @480 Vac, UL 489

Trip
Function

50kA
Product Number

List Price,
GO-135PM

65kA
Product Number

List Price,
GO-135PM

100kA
Product Number

List Price,
GO-135PM

LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2
LIT
LSIT
LIGT2
LSIGT2

SKHH36DA0800
SKHH36DB0800
SKHH36DC0800
SKHH36DD0800
SKHH36DA1000
SKHH36DB1000
SKHH36DC1000
SKHH36DD1000
SKHH36DA1200
SKHH36DB1200
SKHH36DC1200
SKHH36DD1200

$10375.00
$11740.00
$11585.00
$12950.00
$14024.00
$15389.00
$15234.00
$16599.00
$14024.00
$15389.00
$15234.00
$16599.00

SKLL36DA0800
SKLL36DB0800
SKLL36DC0800
SKLL36DD0800
SKLL36DA1000
SKLL36DB1000
SKLL36DC1000
SKLL36DD1000
SKLL36DA1200
SKLL36DB1200
SKLL36DC1200
SKLL36DD1200

$12292.00
$13657.00
$13502.00
$14867.00
$16814.00
$18179.00
$18024.00
$19389.00
$16814.00
$18179.00
$18024.00
$19389.00

SKPP36DA0800
SKPP36DB0800
SKPP36DC0800
SKPP36DD0800
SKPP36DA1000
SKPP36DB1000
SKPP36DC1000
SKPP36DD1000
SKPP36DA1200
SKPP36DB1200
SKPP36DC1200
SKPP36DD1200

$13754.00
$15119.00
$14964.00
$16329.00
$17810.00
$19175.00
$19020.00
$20385.00
$17810.00
$19175.00
$19020.00
$20385.00

MicroVersaTrip Plus and PM Rating Plug Selection —
All Plugs List Price, $106.00

800
SKHB, SKHH, SKLB,
SKLL, SKPB, SKPP

1200

300
400
500
600
700
800
600
700
800
1000
1200

List Price,
GO-135S

Wire Range

TCAL81

$47.00

(3) 3/0-500 Cu
(3) 3/0-500 Al

TCAL125

$76.00

Product Number

(4) 250-350 Cu3
(4) 250-500 Al

GO-135S
SRPK800B300
SRPK800B400
SRPK800B500
SRPK800B600
SRPK800B700
SRPK800B800
SRPK1200B600
SRPK1200B700
SRPK1200B800
SRPK1200B1000
SRPK1200B12006

1MicroVersaTrip PM Trip Units require 24 Vdc control power and voltage sensing signals. Refer to pages 3-106 to 3-109.
2For grounded neutral systems (1**/3w or 3**4w) a neutral current sensor is required. Refer to page 3-109.
3Suitable for 500 kcmil copper, 1200A max. rating.
4For ground fault neutral current sensor, use 1200A rating.
5100% UL rated SK1200 supplied with back-connected assembly which increases breaker depth. Refer to outline drawing 168D1678 Sh2 for details.
6Not suitable for use with 100% rated, 1000A breaker frame.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-68
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
300-1200A Circuit Breakers
Thermal-Magnetic Trip
K1200 Line Circuit Breakers
Types TKM, THMK

Types TKM, THKM — Interchangeable Trip, not suitable for reverse feed

GO-135B

Complete Circuit Breaker
Includes Line and Load Lugs

Terminal Lugs for Front
Connection (Cu/Al)1

Adjustable Instantaneous
AmpereTrip Ampere Range
Standard
Rating Low
High
Product Number

List
Price

Hi-Break1
Product Number

List
Price

800A
300
350
400
450
500
600
700
800

Frame—Two-Pole
900
3000 TKMA826300WL
1050 3500 TKMA826350WL
1200 4000 TKMA826400WL
1350 4500 TKMA826450WL
1500 5000 TKMA826500WL
1800 6000 TKMA826600WL
2100 6400 TKMA826700WL
2400 6400 TKMA826800WL

$3672.00
$3672.00
$3672.00
$3672.00
$3672.00
$3672.00
$3700.00
$3700.00

THKMA826300WL
THKMA826350WL
THKMA826400WL
THKMA826450WL
THKMA826500WL
THKMA826600WL
THKMA826700WL
THKMA826800WL

$4579.00
$4579.00
$4579.00
$4579.00
$4579.00
$4579.00
$4611.00
$4611.00

800A
300
350
400
450
500
600
700
800
800
Mag
Only

Frame—Three-Pole
900
3000 TKMA836300WL
1050 3500 TKMA836350WL
1200 4000 TKMA836400WL
1350 4500 TKMA836450WL
1500 5000 TKMA836500WL
1800 6000 TKMA836600WL
2100 6400 TKMA836700WL
2400 6400 TKMA836800WL
1200 4000
—
2400 8000
—

$4713.00
$4713.00
$4713.00
$4713.00
$4713.00
$4713.00
$4755.00
$4755.00
—
—

THKMA836300WL
THKMA836350WL
THKMA836400WL
THKMA836450WL
THKMA836500WL
THKMA836600WL
THKMA836700WL
THKMA836800WL
—
—

$5624.00
$5624.00
$5624.00
$5624.00
$5624.00
$5624.00
$5666.00
$5666.00
—
—

Frame Only
Product Number

List
Price

TKM826F000
Standard
Frame

$1244.00

THKM826F000
Hi-Break Frame

TKM836F000
Standard
Frame

THKM836F000
Hi-Break Frame

$2167.00

$2205.00

$3116.00

Trip Unit Only. Use
with Standard and
Hi-Break Frames

List
Price

TKMA836T300
TKMA836T350
TKMA836T400
TKMA836T450
TKMA836T500
TKMA836T600
TKMA836T700
TKMA836T800

$2268.00
$2268.00
$2268.00
$2268.00
$2268.00
$2268.00
$2268.00
$2268.00

TKMA836T300
TKMA836T350
TKMA836T400
TKMA836T450
TKMA836T500
TKMA836T600
TKMA836T700
TKMA836T800

$2268.00
$2268.00
$2268.00
$2268.00
$2268.00
$2268.00
$2268.00
$2268.00

TKMA836TM483

$2268.00
$2268.00

TKMA836TM683

Product Number
(Order 2
List
per pole)
Price

Wire Size

TCAL61

$40.00

(2) 2/0-500
Cu/Al

TCAL81

$47.002

(3) 3/0-500
Cu/Al

TCAL61

$40.00

(2) 2/0-500
Cu/Al

TCAL81

$47.004

(3) 3/0-500
Cu/Al

1For optional lugs, see page 3-101.
2Not UL listed.
3Internal accessory installation requires dummy trip unit. See page 3-91 for additional details. Nonautomatic trip unit and dummy trip unit not UL listed for field installation.

MOLDED CASE
CIRCUIT BREAKERS

4GO-135S.

3

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-69
Prices and data subject to change without notice

Molded Case Circuit Breakers

Industrial Circuit Breakers
300-1200A Circuit Breakers
Thermal-Magnetic Trip
K1200 Line Circuit Breakers
Types TKM, THMK

Types TKM, THKM — Interchangeable Trip, not suitable for reverse feed

GO-135B

Complete Circuit Breaker
Includes Line and Load Lugs

Terminal Lugs for Front
Connection (Cu/Al)1

Adjustable Instantaneous
AmpereTrip Ampere Range
Standard
Rating Low
High
Product Number

List
Price

Hi-Break1
Product Number

List
Price

Frame Only
Product Number

List
Price

1200A Frame—Two-Pole
600
1800 6000 TKMA20600WL
700
2100 6400 TKMA20700WL
800
2400 6400 TKMA20800WL
1000 3000 10000 TKMA21000WL3
1200 3600 10000 TKMA21200WL3

$5172.00
$5172.00
$5172.00
$5472.00
$7471.00

THKMA20600WL
THKMA20700WL
THKMA20800WL
THKMA21000WL3
THKMA21200WL3

$6069.00
$6069.00
$6069.00
$6353.00
$8368.00

TKM2F
Standard
Frame

$2690.00

THKM2F
Hi-Break Frame
1200A Frame—Three-Pole
500
600
1800 6000 TKMA30600WL
700
2100 6400 TKMA30700WL
800
2400 6400 TKMA30800WL
1000 3000 10000 TKMA31000WL4
1200 3600 10000 TKMA31200WL4
1200
Mag 1800 6000
—
Only 2400 8000
—

Trip Unit Only. Use
with Standard and
Hi-Break Frames

List
Price

TKMA3T0600
TKMA3T0700
TKMA3T0800
TKMA3T10004
TKMA3T12004

$2294.00
$2294.00
$2294.00
$2478.00
$4477.00

TKMA3T0500
TKMA3T0600
TKMA3T0700
TKMA3T0800
TKMA3T10004
TKMA3T12004
TKMA3TM5123
TKMA3TM6123

Product Number
(Order 2
List
per pole)
Price
TCAL81

$47.002

TCAL121

$76.002

$2294.00
$2294.00
$2294.00
$2478.00
$4477.00

TCAL81

$47.002

$4477.00
$4477.00

TCAL121

$76.002

$3587.00

$5885.00
$5885.00
$5885.00
$6243.00
$8242.00

THKMA30600WL
THKMA30700WL
THKMA30800WL
THKMA31000WL4
THKMA31200WL4

$6795.00
$6795.00
$6795.00
$7153.00
$9152.00

TKM3F
Standard
Frame

$3309.00

—
—

—
—

—
—

THKM2F
Hi-Break Frame

$4219.00

Wire Size
(3) 3/0-500
Cu/Al
(4) 250-3505
Cu or
(4) 300-500
Al

(3) 3/0-500
Cu/Al

(4) 250-3505
Cu or
(4) 300-500
Al

1For optional lugs, see page 3-101.
2GO-135S.
3Not UL listed.
4Not Suitable for use on dc systems.
5Suitable for 500 kcmil Cu for voltage drop considerations.

MOLDED CASE
CIRCUIT BREAKERS

Accessories: See pages 3-85 to 3-104.

3

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-70
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Industrial Circuit Breakers
400-2000A Circuit Breakers
Electronic Trip

R Frame Circuit Breaker Frames
—R-Frame Molded Case Circuit Breaker Frames
—600 Vac, 50/60 Hz, 3-Poles only. Suitable for Reverse Feed
—Complete breaker requires frame and rating plug.
—For 4-wire GF application, select neutral CT from page 3-105,
order separately.
—IC Ratings shown are at 480 Vac.

Circuit Breaker Frame Selection
MicroVersaTrip Plus Trip Units

R-Frame Current Sensors and Rating Plugs
GO-135S

1000 A

1600 A

2000 A

Trip
Function
LIT
LSIT
LIGT
LSIGT
LIGTZ1
LSIGTZ1
LSIGTZ2
LIT
LSIT
LIGT
LSIGT
LIGTZ1
LSIGTZ1
LSIGTZ2
LIT
LSIT
LIGT
LSIGT
LIGTZ1
LSIGTZ1
LSIGTZ2

65kAIC
Product Number
List Price
TRLA36BA10
$10610.00
TRLA36BB10
$11975.00
TRLA36BC10
$11820.00
TRLA36BD10
$13185.00
TRLA36BE10
$12405.00
TRLA36BF10
$13770.00
TRLA36BG10
$14355.00
TRLA36BA16
$10610.00
TRLA36BB16
$11975.00
TRLA36BC16
$11820.00
TRLA36BD16
$13185.00
TRLA36BE16
$12405.00
TRLA36BF16
$13770.00
TRLA36BG16
$14355.00
TRLA36BA20
$11488.00
TRLA36BB20
$12853.00
TRLA36BC20
$12698.00
TRLA36BD20
$14063.00
TRLA36BE20
$13283.00
TRLA36BF20
$14648.00
TRLA36BG20
$15233.00

Standard Rating
Current
Sensor

1000 A

1600 A

2000 A

Trip
Function
LIT
LSIT
LIGT
LSIGT
LIGTZ1
LSIGTZ1
LSIGTZ2
LIT
LSIT
LIGT
LSIGT
LIGTZ1
LSIGTZ1
LSIGTZ2
LIT
LSIT
LIGT
LSIGT
LIGTZ1
LSIGTZ1
LSIGTZ2

100kAIC
Product Number
List Price
TRPA36BA10
$12465.00
TRPA36BB10
$13830.00
TRPA36BC10
$13675.00
TRPA36BD10
$15040.00
TRPA36BE10
$14260.00
TRPA36BF10
$15625.00
TRPA36BG10
$16210.00
TRPA36BA16
$12465.00
TRPA36BB16
$13830.00
TRPA36BC16
$13675.00
TRPA36BD16
$15040.00
TRPA36BE16
$14260.00
TRPA36BF16
$15625.00
TRPA36BG16
$16210.00
TRPA36BA20
$13472.00
TRPA36BB20
$14837.00
TRPA36BC20
$14682.00
TRPA36BD20
$16047.00
TRPA36BE20
$15267.00
TRPA36BF20
$16632.00
TRPA36BG20
$17217.00

100% Rating
65kAIC
Product Number
List Price
TRLL36BA10
$13871.00
TRLL36BB10
$15236.00
TRLL36BC10
$15081.00
TRLL36BD10
$16446.00
TRLL36BE10
$15666.00
TRLL36BF10
$17031.00
TRLL36BG10
$17616.00
TRLL36BA16
$13871.00
TRLL36BB16
$15236.00
TRLL36BC16
$15081.00
TRLL36BD16
$16446.00
TRLL36BE16
$15666.00
TRLL36BF16
$17031.00
TRLL36BG16
$17616.00
TRLL36BA20
$14986.00
TRLL36BB20
$16351.00
TRLL36BC20
$16196.00
TRLL36BD20
$17561.00
TRLL36BE20
$16781.00
TRLL36BF20
$18146.00
TRLL36BG20
$18731.00

Sensor

Current Rating

1000 A

1600 A

2000 A

Rating Plug
Removal Tool

400 A
600 A
800 A
1000A
600 A
800 A
1000 A
1100 A
1200 A
1600 A
750 A
800 A
1000 A
1200 A
1500 A
1600 A
2000 A

List Price

TR10B400
TR10B600
TR10B800
TR10B1000
TR16B600
TR16B800
TR16B1000
TR16B1100
TR16B1200
TR16B1600
TR20B750
TR20B800
TR20B1000
TR20B1200
TR20B1500
TR20B1600
TR20B2000
TRTOOL

$89.00
$89.00
$89.00
$89.00
$89.00
$89.00
$89.00
$89.00
$89.00
$89.00
$89.00
$89.00
$89.00
$89.00
$89.00
$89.00
$89.00
$12.001

1GO-135S.

MOLDED CASE
CIRCUIT BREAKERS

Standard Rating
Current
Sensor

GO-245A

Rating Plug
Product Number

100% Rating
100kAIC
Product Number
List Price
TRPP36BA10
$16258.00
TRPP36BB10
$17623.00
TRPP36BC10
$17468.00
TRPP36BD10
$18833.00
TRPP36BE10
$18053.00
TRPP36BF10
$19418.00
TRPP36BG10
$20003.00
TRPP36BA16
$16258.00
TRPP36BB16
$17623.00
TRPP36BC16
$17468.00
TRPP36BD16
$18833.00
TRPP36BE16
$18053.00
TRPP36BF16
$19418.00
TRPP36BG16
$20003.00
TRPP36BA20
$17566.00
TRPP36BB20
$18931.00
TRPP36BC20
$18776.00
TRPP36BD20
$20141.00
TRPP36BE20
$19361.00
TRPP36BF20
$20726.00
TRPP36BG20
$21311.00

3

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-71
Prices and data subject to change without notice

Molded Case Circuit Breakers

Molded Case Switches
150-1200A
Spectra RMS

Molded Case Switches
UL File E-57546, CSA LR 91464
Includes fixed, high-set Instantaneous trip suitable for reverse feed.

GO-135S

Frame
Type

Ampere
Rating

Product Number

List Price

SE150

100
150
250

SEDA36AN0100
SEDA36AN0150
SFDA36AN0250

$650.00
$948.00
$1126.00

TCAL18

$3.00

TCAL29

$8.00

400

SGDA36AN0400

$1813.00

3-pole lug kit

600

SGDA36AN0600

$2489.00

TCLK3653

$42.00

800

SKDA36AN0800

$2483.00

TCAL81

$47.00

1000

SKDA36AN1000

$3600.00

1200

SKDA36AN1200

$3600.00

SF250

SG600

SK1200

Maximum Sort Circuit Withstand Rating2
(kA rms symmetrical)

Terminal Lugs for
Front Connection (Cu/Al)

Switch1
Product Number

TCAL125

List Price

$76.00

Wire Range

240 Vac

Aluminum: #12-3/0
Copper: #14-3/0
Aluminum: #8-350 kcmil
Copper: #8-350 kcmil
Aluminum:
(2) 2/0-500 kcmil
or (1) #6-600 kcmil
Copper:
(2) 2/0-500 kcmil
or (1) #8-600 kcmil
Aluminum:
(3) 3/0-500 kcmil
Copper:
(3) 3/0-500 kcmil
Aluminum:
(4) 250-500 kcmil
Copper:
(4) 250-350 kcmil4

200

480 Vac
100

600 Vac
25

200

100

25

200

100

42

100

65

42

1No rating plug required.
2The maximum withstand rating is limited by the application to the value set forth in this table or the short circuit rating of the upstream fuse or circuit breaker, whichever is less. The

upstream protective device must have an instantaneous trip function or element and its rated ampacity may not exceed the ampere rating of the switch.
3Order one kit for either line or load end; two kits required for both.
4Suitable for 500 kcmil copper, 1200A max. rating.

MOLDED CASE
CIRCUIT BREAKERS

Noninterchangeable Trip, Includes Cu/Al load lugs. For optional lugs, see page 3-101 and 3-102.

GO-135B

Type

Ampere Rating

Number of Poles

Voltage Rating

Product Number

List Price

TEB
TEB
TEB
TED
TED
TED
TFJ
TFJ
TJJ
TJJ

100
100
100
100
100
150
225
225
400
400

1
2
3
1
2
2
2
3
2
2

120 Vac, 125 Vdc
240 Vac, 250 Vdc
240 Vac
277 Vac, 125 Vdc
480 Vac, 250 Vdc
480 Vac, 250 Vdc
480 Vac
600 Vac
600 Vac, 250 Vdc
600 Vac

TEB111Y1005
TEB122Y1005
TEB132Y1005
TED113Y1005
TED124Y1005
TED124Y1505,6
TFJ226Y2255,7
TFJ236Y225
TJJ426Y4008
TJJ436Y4008

$65.50
$159.00
$240.00
$82.50
$263.00
$708.00
$803.00
$1174.00
$1577.00
$1904.00

3
Interchangeable Trip, Includes Cu/Al load lugs. For optional lugs, see page 3-101 and 3-102.
Type

Ampere Rating

Number of Poles

Voltage Rating

TFK
TFK
TJK
TJK
TJK
TJK
TMK
TMK
TMK
TMK
TMK
TMK

225
225
400
400
600
600
800
800
1000
1000
1200
1200

2
3
2
3
2
3
2
3
2
3
2
3

480 Vac, 250 Vdc
600 Vac, 250 Vdc
600 Vac, 250 Vdc
600 Vac, 250 Vdc
600 Vac, 250 Vdc
600 Vac, 250 Vdc
600 Vac, 250 Vdc
600 Vac, 250 Vdc
600 Vac, 250 Vdc
600 Vac, 250 Vdc
600 Vac, 250 Vdc
600 Vac, 250 Vdc

GO-135B
Product Number

List Price

TFK226Y2257,8,9
TFK236Y2258,9
TJK426Y4008
TJK436Y4008
TJK626Y6008
TJK636Y6008
TMKA836Y8008
TMKA826Y8008
TMKA2Y10008
TMKA3Y10008
TMKA2Y12008
TMKA3Y12008

$937.00
$1174.00
$1874.00
$2330.00
$1844.00
$2595.00
$1692.00
$2769.00
$3311.00
$4030.00
$3420.00
$4191.00

5Internal accessory requires factory installed dummy trip. Specify on order. Accessories not available for one-pole TEB, TED.
6Not UL listed.
7600 Volts max.
8Internal accessory requires factory installed dummy trip unit. See page 3-91 for additional details. Nonautomatic trip unit and dummy trip not UL listed for field installation.
9UL listed only when ordered as a complete switch.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-72
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Motor Circuit Protectors
3-1200A
Spectra RMS
Spectra RMS Mag-Break Motor Circuit Protectors
Current Limiting, UL Component Recognized 1
Features
—Suitable for Reverse Feed
—UL Recognized File E-11592
—CSA Certified LR 40350
—IEC 947-2 690 Vac Max.
—SE 150
160 Ampere Max.
—SF250
250 Ampere Max.
—SG600
630 Ampere Max.
—SK1200
1250 Ampere Max.
—UL Current Limiting
High Interrupting Capacity Spectra RMS Motor Circuit Protectors
Rating Plug
Adjustable Instantaneous
Trip Ampere Range
Low

Product
Number

High

SE150 Line 3-Pole
3
11
7
22
15
43
20
58
25
73
30
87
40
118
50
148
60
178
70
206
80
236
90
267
100
297
110
328
125
374
150
450

Terminal Lugs for Front Connection (Cu/Al)

39
90
182
254
332
415
501
637
777
863
999
1138
1280
1426
1640
1991

List Price,
GO-135S

SRPE7A3
SRPE7A7
SRPE30A15
SRPE30A20
SRPE30A25
SRPE30A30
SRPE60A40
SRPE60A50
SRPE60A60
SRPE100A70
SRPE100A80
SRPE100A90
SRPE100A100
SRPE150A110
SRPE150A125
SRPE150A150

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

Product
Number

List Price,
GO-141S

100kAIC @480 Vac
Product
Number

List Price,
GO-141S

Product
Number

List Price,
GO-135S

7

SELA36AI0007

$530.00

SEPA36AI0007

$663.00

TCAL18

$3.00

30

SELA36AI0030

$530.00

SEPA36AI0030

$663.00

TCAL18

$3.00

Wire
Range

14-3/0 Cu
60

SELA36AI0060

$686.00

SEPA36AI0060

$858.00

TCAL18

$3.00
12-3/0 Al

100

SELA36AI0100

$754.00

SEPA36AI0100

$943.00

TCAL18

$3.00

150

SELA36AI0150

$848.00

SEPA36AI0150

$1060.00

TCAL18

$3.00

Standard Capacity Mag-Break Motor Circuit Protectors—Adjustable Magnetic Trip, Noninterchangeable Types TEC, TECL

GO-141

Complete Breaker (includes line and load lugs)
Adjustable Trip
Ampere Range2

Two-Pole, 480 Vac3

Three-Pole, 600 Vac

Add-on Limiter Three-Pole,
100 kAIC

Ampere
Rating

Low

High

Product Number

List Price

Product Number

List Price

Product Number

List Price

3
7
15
30
50
100
150

8
18
42
90
180
300
600

38
90
198
390
660
1300
2700

TEC24003
TEC24007
TEC24015
TEC24030
TEC24050
TEC24100
TEC24150

$318.00
$318.00
$318.00
$318.00
$377.00
$413.00
$477.00

TEC36003
TEC36007
TEC36015
TEC36030
TEC36050
TEC36100
TEC36150

$388.00
$388.00
$388.00
$388.00
$464.00
$498.00
$545.00

TECL36003
TECL36007
TECL36015
TECL36030
TECL36050
TECL36100
TECL36150

$231.00
$231.00
$231.00
$231.00
$231.00
$524.00
$1079.00

1Per UL 489, interrupting capacities are not shown on product label.
2AC only
3Two-pole furnished in three-pole case.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-73
Prices and data subject to change without notice

MOLDED CASE
CIRCUIT BREAKERS

Ampere
Rating

Frame
65kAIC @480 Vac

3

Molded Case Circuit Breakers

Motor Circuit Protectors
150-1200A
Spectra RMS
Spectra RMS Mag-Break Motor Circuit Protectors
Current Limiting, UL Component Recognized 1

SF250 Line 3-Pole
Rating Plug

Ampere
Rating

Low

SE150 Line 3-Pole
70
205
90
265
100
295
110
325
125
370
150
440
175
515
200
590
225
665
250
736

Product
Number

High
700
900
1000
1100
1250
1500
1750
2000
2250
2500

Frame

Terminal Lugs for Front Connection (Cu/Al)

65kAIC @480 Vac

Adjustable Instantaneous
Trip Ampere Range

List Price,
GO-135S

SRPF250A70
SRPF250A90
SRPF250A100
SRPF250A110
SRPF250A125
SRPF250A150
SRPF250A175
SRPF250A200
SRPF250A225
SRPF250A250

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Current
Sensor

250

100kAIC @480 Vac

Product
Number

List Price,
GO-141S

Product
Number

List Price,
GO-141S

SFLA36AI0250

$1297.00

SFPA36AI0250

$1622.00

Product
Number

TCAL29

Types TFC, TJC, TKC 3-Pole

$8.00

8-350 Cu
8-350 Al

Complete Breaker (includes line and load lugs)

Ampere Rating

Low

High

Product Number

List Price

225

600
100
330
550
1000
1200
1000
1800
3000
5000
3000
5000

1400
2250
1100
1670
3300
4000
3300
6000
6000
10000
6000
10000

TFC36225
TFC36225A
TJC36400E
TJC36400F
TJC36400G
TJC36400B
TJC36600G
TJC36600H
TKC36800L2
TKC36800M2
TKC361200L2
TKC361200M2

$1448.00
$1448.00
$2589.00
$2589.00
$2589.00
$2589.00
$3676.00
$3676.00
$4880.00
$4880.00
$8412.00
$8412.00

400

600
800

MOLDED CASE
CIRCUIT BREAKERS

Wire
Range

GO-135B
Adjustable Instantaneous
Trip Ampere Range

3

List Price,
GO-135S

1200
1200

Type TBC with Current Limiters

GO-135B
Complete Breaker (includes line and load lugs)
Adjustable Instantaneous
Trip Ampere Range

Standard Replacement
Current Limiters

Three-Pole

Ampere Rating

Low

High

Product Number

List Price

Product Number

List Price

225
400
600
800

550
1000
3000
2400

1670
3300
6000
6000

TBC43225F14F
TBC43400F14G
TBC63600J14L
TBC83800K222

$3810.00
$5149.00
$7443.00
$8622.00

TB10F14
TB10F14
TB10BJ14
TB15K22

$377.00
$377.00
$543.00
$543.00

1Per UL 489, interrupting capacities are not shown on product label.
2Balanced three-phase inrush current will trip the circuit breaker at lower than indicated currents.

For motors over 350 hp, use Spectra RMS SK frame or circuit breakers with MicroVersaTrip Plus Trip Units

Accessories: See pages 3-83 to 3-104.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-74
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Motor Circuit Protectors
150-1200A
Spectra RMS
Spectra RMS Mag-Break Motor Circuit Protectors
Current Limiting, UL Component Recognized 1

SG 600 Line 3-Pole
Rating Plug

Ampere
Rating

Frame
65kAIC @480 Vac

Adjustable Instantaneous
Trip Ampere Range
Low

High

Product
Number

List Price,
GO-135S

400 Ampere Max.
125
380
150
455
175
530
200
605
225
680
250
755
300
905
350
1060
400
1210

1275
1530
1785
2040
2295
2550
3060
3570
4080

SRPG400A125
SRPG400A150
SRPG400A175
SRPG400A200
SRPG400A225
SRPG400A250
SRPG400A300
SRPG400A350
SRPG400A400

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

600 Ampere
250
300
350
400
450
500
600

2530
3035
3545
4050
4555
5060
6075

SRPG600A250
SRPG600A300
SRPG600A350
SRPG600A400
SRPG600A450
SRPG600A500
SRPG600A600

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

Max.
765
915
1070
1220
1375
1525
1830

Current
Sensor

Product
Number

List Price,
GO-141S

Terminal Lugs for Front Connection (Cu/Al)
100kAIC @480 Vac
Product
Number

List Price,
GO-141S

Product
Number

List Price,
GO-135S

3-Pole
lug kit
400

SGLA36AI0400

$2396.00

SGPA36AI0400

$2995.00

TCLK3652

Wire
Range

(2) 2/0-500 Cu
or
(1) 8-600 Cu
$42.00
(2) 2/0-500 Al
or
(1) 6-600 Al

3-Pole
lug kit
600

SGLA36AI0600

$3481.00

SGPA36AI0600

$4350.00

TCLK3652

(2) 2/0-500 Cu
or (1) 8-600 Cu
$42.00

(2) 2/0-500 Al
or (1) 6-600 Al

SK1200 Line (Not Current Limiting) 3-Pole
Rating Plug

Frame

Low

High

Product
Number

List Price,
GO-135S

Max.
940
1250
1570
1875
2155
2440

3015
4015
5020
6195
7420
8705

SRPK800A300
SRPK800A400
SRPK800A500
SRPK800A600
SRPK800A700
SRPK800A800

$106.00
$106.00
$106.00
$106.00
$106.00
$106.00

1200 Ampere Max.
600
1825
700
2125
800
2430
100
3040
1200
3650

6110
7125
8145
10180
12215

SRPK1200A600
SRPK1200A700
SRPK1200A800
SRPK1200A1000
SRPK1200A1200

$106.00
$106.00
$106.00
$106.00
$106.00

800 Ampere
300
400
500
600
700
800

Terminal Lugs for Front Connection (Cu/Al)

65kAIC @480 Vac
Current
Sensor

Product
Number

List Price,
GO-141S

Product
Number

List Price,
GO-135S

$4490.00

TCAL81

$47.00

Wire
Range

(3) 3/0-500 Cu
800

SKLA36AI0800

(3) 3/0-500 Al

(4) 250-500 Cu3
1200

SKLA36AI1200

$7859.00

TCAL125

$76.00
(4) 250-350 Al

1Per UL 489, interrupting capacities are not shown on product label.
2Order one kit for either the line or load end; two kits required for both.
3Suitable for 500 kcmil copper, 1200A max. rating.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

MOLDED CASE
CIRCUIT BREAKERS

Ampere
Rating

Adjustable Instantaneous
Trip Ampere Range

3-75
Prices and data subject to change without notice

3

Molded Case Circuit Breakers

Special Purpose
Mine Duty Breakers
Mine Duty Circuit Breakers
Standard Duty
50-1200 amperes
600 Vac
300 Vdc

Three-Pole 1000 Wye 577 Vac (Not UL Listed) — Without Line or Load Lugs 1

GO-135A

Complete Breaker

Frame Only

Thermal Magnetic
Ampere
Rating

Magnetic Instantaneous Trip
Low

High

Product
Number

Trip Unit Only

Magnetic Only
List Price

Product
Number

Thermal Magnetic
List Price

Product
Number

Product
Number

List Price

Magnetic Only
List Price

Product
Number

List Price

E Frame — 100 Amperes Maximum, Noninterchangeable Trip
50
502
1802
TE131050MD
$1104.00 TE131M050MD $1104.00
100
1002
5002
TE131100MD
$1104.00 TE131M100MD $1104.00

—
—

J Frame — 225 Amperes Maximum, Interchangeable Trip3
225
300
1000
TJ132225MD1
225
500
1500
TJ132225MD2

—
—

TJ132M2MD1
TJ132M2MD2

—
—

TJ132FMD
—

$3231.00 TJ32225TMD1
—
TJ32225TMD2

$920.00
$920.00

TJ32M2TMD1
TJ32M2TMD2

$920.00
$920.00

J Frame — 400 Amperes Maximum, Interchangeable Trip3
400
500
1500
TJ134400MD2
400
900
3000
TJ134400MD3

—
—

TJ134M4MD2
TJ134M4MD3

—
—

TJ134FMD
—

$4499.00 TJ34400TMD2
—
TJ34400TMD3

$1007.00
$1007.00

TJ34M4TMD2
TJ34M4TMD3

$1007.00
$1007.00

J Frame — 600 Amperes Maximum, Interchangeable Trip3
600
900
3000
TJ136600MD3

—

TJ136M6MD3

—

TJ136FMD

$4636.00 TJ36600TMD3

$1071.00

TJ36M6TMD3

$1671.00

—
—
—
—
—
—

—
—
—
—
TK13M8MD4
TK13M8MD5

—
—
—
—
—
—

—
—
TK138FMD
—
—
—

—
—
$5296.00
—
—
—

$1815.00
$1815.00
$2813.00
$2813.00
$2813.00
$2813.00

—
—
—
—
TK38M8TMD4
TK38M8TMD5

—
—
—
—
$2813.00
$2813.00

—
—

—
TK13M12MD5

—
—

TK13AFMD
—

$7600.00 TK3A10TMD5
—
TK3A12TMD5

$5923.00
$5923.00

—
TK3M12TMD5

—
$5923.00

—
—

—
—

—
—

—
—

—
—

Interchangeable Trip3

K Frame — 800 Amperes Maximum,
300
900
3000
400
1250
3000
600
1250
3000
600
2000
4000
800
1250
3000
800
2000
4000

TK138600MD3
TK138400MD4
TK138600MD4
TK138600MD5
TK138800MD4
TK138800MD5

MOLDED CASE
CIRCUIT BREAKERS

K Frame — 1200 Amperes Maximum, Interchangeable Trip3,4
800
2000
4000
TK13A10MD5
800
2000
4000
TK13A12MD5

TK38300TMD3
TK38400TMD4
TK38600TMD4
TK38600TMD5
TK38800TMD4
TK38800TMD5

1The lugs recommended for use with all Mine Duty breakers are copper for use with copper cable. Select from page 3-101.
2Applies only to magnetic-only breakers.
3Order frame plus trip unit; not available as complete breaker.
4Not suitable for use on dc.

Accessories: See pages 3-85 to 3-104.

3

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-76
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Replacement Breakers
TriBreak
Internally Fused

TB1

TB4

TB6

TB1, 150A Frame, Noninterchangeable Trip (Includes line and load lugs)
Adjustable Instantaneous
Trip Amperes Range
Low
High

15
20
25
30
35
40
45
50
60
70
80
90
100
100NA

Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
–

TB13015BWE05
TB13020BWE05
TB13025BWE05
TB13030BWE05
TB13035BWE05
TB13040BWE05
TB13045BWE05
TB13050BWE09
TB13060BWE09
TB13070BWE09
TB13080BWE09
TB13090BWE09
TB13100BWE09
TB13BYWE095,6

GO-135B

Lugs2
Product No.
and Wire Sizes
(order 2 per pole)

$2680.004
$2680.004
$2680.004
$2680.004
$2680.004
$2680.004
$2680.004
$2680.004
$2680.004
$2680.004
$2680.004
$2680.004
$2680.004
$2680.004

TCAL14
#14-8
Cu-Al
TCAL 12
#14-2/0
Cu-Al

TCAL 12
#14-2/0
Cu-Al

List
Price

Trip Units3
Product
Number

List
Price

Lugs
Furnished
with
Breaker

Lugs
Furnished
with
Breaker

Replacement
Current Limiters1
Standard
Optional1
Product
List
Product
Number
Price
Number

TB4E05

$280.004

Not
Available

TB7E09

$360.004

TB4E05

TB4, 400A Frame, Interchangeable Trip (Without line or load lugs)

Ampere
Rating
125
150
175
200
225
250
300
350
400
400NA

Adjustable Instantaneous
Trip Amperes Range
Low
High
375
450
525
600
675
750
900
1050
1200
–

1250
1500
1750
2000
2250
2500
3000
3500
3500
–

Tri-Break—Including
Current Limiters1
Three-Pole
Product
List
Number
Price
TB43125AF14
TB43150AF14
TB43175AF14
TB43200AF14
TB43225AF14
TB43250AF14
TB43300AF14
TB43350AF14
TB43400AF14
TB43AYW F145,6

$4079.00
$4079.00
$4079.00
$4079.00
$4079.00
$5542.00
$5542.00
$5542.00
$5542.00
$4802.00

List
Price

$280.004

GO-135B
Lugs2

Product No.
and Wire Sizes
(order 2 per pole)

List
Price
$14.00

TCAL43
TCAL43
(1) 6-600 kcmil
(1) 6-600 kcmil $14.00
or
or
(2) 2/0-250 kcmil
(2) 2/0-250 kcmil

Trip Units3
Product
Number

List
Price

TB43T125
TB43T150
TB43T175
TB43T200
TB43T225
TB43T250
TB43T300
TB43T350
TB43T400
–

$473.00
$473.00
$473.00
$473.00
$473.00
$1931.00
$1931.00
$1931.00
$1931.00
–

Replacement
Current Limiters1
Standard
Optional1
Product
List
Product
Number
Price
Number

TB10F14

$377.00

TB3F05
or
TB6F09

List
Price

$401.00
$377.00

–
–
1Standard current limiters (bolt on: TB1, TB6, TB8 and plug-in: TB4) have been selected based upon recommended coordination with thermal

3

magnetic trip characteristics of the breaker. Optional current limiters are not UL listed in combination with breaker except TB4 with
TB3F05 or TB6F09, 250A maximum.
2For optional lugs, see page 3-101.
3Trip units fit 2 and 3 pole frames.
4GO-148D.
5Molded case switch. Includes dummy trip, line and load lugs.
6Not UL listed.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

MOLDED CASE
CIRCUIT BREAKERS

Ampere
Rating

Tri-Break—Including
Current Limiters1
Three-Pole
Product
List
Number
Price

3-77
Prices and data subject to change without notice

Molded Case Circuit Breakers

Replacement Breakers
TriBreak
Internally Fused

TB6, 600A Frame, Interchangeable Trip (Without line or load lugs)

Ampere
Rating
300
350
400
500
600
600NA

Adjustable Instantaneous
Trip Amperes Range
Low
High
1200
1200
1200
1200
1200
–

3500
3500
3500
3500
3500
–

TB63300BJ14
TB63350BJ14
TB63400BJ14
TB63500BJ14
TB63600BJ14
TB63BYWJ144

GO-135B
Lugs2

Tri-Break—Including
Current Limiters1
Three-Pole
Product
List
Number
Price

Product No.
and Wire Sizes
(order 2 per pole)

$7123.00
$7123.00
$7123.00
$7123.00
$7123.00
$6894.00

TCAL61
TCAL61
(2) 2/0-500
(2) 2/0-500 kcmil
kcmil
–

List
Price

$40.00
40.00
–

Trip Units3
Product
Number

List
Price

TB63T300
TB63T350
TB63T400
TB63T500
TB63T600
–

$2334.00
$2334.00
$2334.00
$2334.00
$2334.00
–

Replacement
Current Limiters1
Standard
Optional1
Product
List
Product
Number
Price
Number

TB10BJ14

$543.00

TB3BJ05
or
TB6BJ09

TB8, 800A Frame, Interchangeable Trip (Without line or load lugs)

Ampere
Rating
600
700
800
800NA

Adjustable Instantaneous
Trip Amperes Range
Low
High
1800
2100
2400
–

3000
4000
4000
–

TB83600BK22
TB83700BK22
TB83800BK22
TB83AYWK224,5

Product No.
and Wire Sizes
(order 2 per pole)

$8204.00
$8204.00
$8204.00
$8204.00

$579.00
$543.00

GO-135B
Lugs2

Tri-Break—Including
Current Limiters1
Three-Pole
Product
List
Number
Price

List
Price

TCAL81
(3) 250-500 kcmil
–

List
Price
$47.00
–

Trip Units3
Product
Number

List
Price

TB83T600
TB83T700
TB83T800
–

$2334.00
$2334.00
$2334.00
–

Replacement
Current Limiters1
Standard
Optional1
Product
List
Product
Number
Price
Number
TB15K22

543.00

TB6BJ095
or
TB10BJ145

List
Price
$543.00
$543.00

MOLDED CASE
CIRCUIT BREAKERS

Old Style (Plug-in) Replacement Limiters
Replacement Limiter1

Breaker
Type

Ampere
Range

Standard

TB1
TB1
TB1
TB6
TB8

15-45
50-100
110-150
300-600
600-800

TB3E05
TB6E09
TB7E10
TB10J14
TB15K18

Optional1
TB3E05
TB3J05
-

TB7E09
TB6J09
-

1Standard current limiters (bolt on: TB1, TB6, TB8 and plug-in: TB4) have been selected

based upon recommended coordination with thermal magnetic trip characteristics of
the breaker. Optional current limiters are not UL listed in combination with breaker
except TB4 with TB3F05 or TB6F09, 250A maximum.
2For optional lugs, see page 3-101.
3Trip units fit 2 and 3 pole frames.
4Molded case switch. Includes dummy trip, line and load lugs.
5Not UL listed.
6GO-135S.

3

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-78
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Replacement Breakers
THLC Current Limiting
Unfused
15-400 Amperes
200kAIC @ 240 Vac max.
200kAIC @480 Vac max.
50kAIC @600 Vac max.

Ampere Rating

3-Pole Product Number

15
20
30
40
50
60
70
80
90
100
125
150

THLC136015WL
THLC136020WL
THLC136030WL
THLC136040WL
THLC136050WL
THLC136060WL
THLC136070WL
THLC136080WL
THLC136090WL
THLC1360100WL
THLC1360125WL
THLC1360150WL

GO-135B
List Price
$2910.00
$2910.00
$2910.00
$2910.00
$2910.00
$2910.00
$2910.00
$2910.00
$2910.00
$2910.00
$5520.00
$5520.00

Internal accessories for THLC1 are same as Type TED accessories. Refer to pages 3-86 to
3-91.

THLC2, 225A Frame, 125-225 Amperes,
Noninterchangeable Trip with Line and Load Lugs
Ampere Rating
125
150
175
200
225

Adjustable Trip
Range Amperes
Low
High
550
675
775
900
1000

1250
1500
1750
2000
2500

THLC1

GO-135B

3-Pole Product Number

List Price

THLC236125WL
THLC236150WL
THLC236175WL
THLC236200WL
THLC236225WL

$5540.00
$5540.00
$5540.00
$5540.00
$5540.00

Internal accessories for THLC2 and THLC4 are same as Type TFK accessories. Refer to
pages 3-87 to 3-91. Accessory must have code date 535+ or later.

THLC4, 400A Frame, 250-400 Amperes,
Noninterchangeable Trip without Line and Load Lugs 1

GO-135B

THLC2

Adjustable Trip
Range Amperes
Ampere Rating

Low

High

3-Pole Product Number

List Price

250
300
350
400

1175
1400
1650
1870

2500
3000
3500
4000

THLC436250
THLC436300
THLC436350
THLC436400

$7450.00
$7450.00
$7450.00
$7450.00

3

1Lug kit for THLC4 for line or load end. Order Product Number TCLK43, List Price $49.00,

GO-135B. Consists of three-pole assembly. Wire range (1) 3/0-500 or (2) 3/0-250 Cu-Al.

THLC4

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

MOLDED CASE
CIRCUIT BREAKERS

THLC1, 150A Frame, 15-150 Amperes,
Noninterchangeable Trip with Line and Load Lugs

BuyLog Catalog

3-79
Prices and data subject to change without notice

Molded Case Circuit Breakers

Replacement Breakers
J and K Frame Circuit Breakers with MicroVersaTrip Plus Trip Units
For Replacement Use Only
For New Breaker Designs, use Spectra RMS Breakers with MicroVersaTrip Plus
How To Order
—Determine the required breaker frame (i.e. 600 or 1200 amperes),
IC rating, and load requirements (UL Standard or 100%). Select
frame product number and list price from table below.
—Select and price the appropriate trip unit from table below.
—Select and price the required rating plug from table below. The
sensor rating of frame must match the sensor rating of the rating
plug in table.
—Select and price lugs and lug covers as required from pages 3-101
and 3-102.
—When ordering, specify separate product numbers as follows.
The trip unit will be installed in the frame. Rating plugs and lugs/lug
covers will be shipped unassembled.
—Frame
—Trip Unit
—Rating plug
—Lugs/Lug covers
—Other accessories (assembled or separate items)

Pricing Example
J600 frame, 300 ampere sensor, 250 ampere rating plug, 35kAIC,
480 Vac, IC 100% rated, trip unit functions to include long-time (L),
short-time (S), instantaneous (I), ground fault (G), trip targets (T2),
ground fault/short-time zone selective interlocking (Z2),
3-phase/3-wire system.
Product
Number

Description
Frame
Trip Unit and Suffix Adder
Rating Plug
Zone Interlock Module (120 Vac)
Neutral Current Sensor
Lugs

List Price,
GO-135D

TJH3SS
TS20LSIGT2Z2
TR3S250J
TIM1
TSRG203

$4774.00
$4915.00
$106.00
$402.001
$532.002

1GO-245B.
2GO-135S.

MicroVersaTrip Plus Trip Unit Characteristics
Long-Time 2

Current Setting
(Multiple of rating
plug ampere) (X)

MOLDED CASE
CIRCUIT BREAKERS

1.0, .95, .90, .85,
.80, .70, .60, .50

Short-Time

Delay (Seconds)

Pick-Up (Multiple of
Current Setting) (C)

2.4, 4.9, 9.8, 20
at 600% of current
setting at lower
limit of each band

1.5, 2.0, 2.5, 3.0,
4.0, 6.0, 7.0, 9.0

Delay (Seconds)
I2t in;3
.44
I2t out:5
.10, .21, .35

Adjustable
Instantaneous Pick-Up
(Multiple of Rating
Plug Amperes) (X)

Ground Fault
Pick-Up (Multiple of
Sensor Ampere Rating) (S)

1.5, 2.0, 3.0, 5.0, 7.0, 9.0,
10.0 without short-time
1.5, 2.0, 3.0, 5.0, 7.0,
9.0, 10.0, 13.0, 15.0 6
with short-time

.20, .25, .30,
.35, .40, .45, .50, .60

Delay (Seconds)
I 2t in;4
.44
I 2t out:5
.10, .21, .35

2 Pick-up fixed at 1.1C.
3 Time delay at 600% of current setting at lower limit of band.
4Time delay at 200% of pick-up setting at lower limit of band.
5 Time delay shown at lower limit of each band. Pick-up tolerances ±10%. Ground fault pick-up not to exceed 1200 amperes.
6 J600 frame with 600 amp sensor for high IC 65kA rating (TJL) limited to 10X

.

X = rating plug amperes
S = sensor ampere rating
C = current setting

3
Circuit Breaker Frame Selection (less lugs)
Frame
Type
J600

K1200

Sensor Rating
(Amperes)
150
300
400
600
800
1200

65 kAIC
Product Number
TJL1S
TJL3S
TJL4S
TJL6S
TKL8S
TKL12S

GO-135D
List
Price
$5149.00
$5149.00
$5149.00
$6222.00
$8603.00
$12536.00

100% 65 kAIC
Product Number
TJL1SS
TJL3SS
TJL4SS
TJL6SS
TKL8SS
TKL12SS

List
Price
$5919.00
$5919.00
$5919.00
$7155.00
$9892.00
$14414.00

Hi-Break
Product Number
TJH1S
TJH3S
TJH4S
TJH6S
TKH8S
TKH12S

List
Price

100% Hi-Break7
Product Number

$4151.00
$4151.00
$4151.00
$5018.00
$6935.00
$10108.00

TJH1SS
TJH3SS
TJH4SS
TJH6SS
TKH8SS
TKH12SS

List
Price
$4774.00
$4774.00
$4774.00
$5771.00
$7975.00
$11624.00

7100% supplied with back-connected assembly which increases breaker depth. Refer to outline drawing 139C4335 Sh7 for details.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-80
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Replacement Breakers
J and K Frame Circuit Breakers with MicroVersaTrip Trip Units
For Replacement Use Only
For New Breaker Designs, use Spectra RMS Breakers with MicroVersaTrip Plus
J/K Rating Plug Selection—All plugs List Price, $106.00
Frame
Type

Sensor Rating
(Amperes)

Current Rating
(Amperes)

Rating Plug
Product Number

60
80
100
125
150
150
200
225
250
300
150
200
225
250
300
400

TR1S60J
TR1S80J
TR1S100J
TR1S125J
TR1S150J
TR3S150J
TR3S200J
TR3S225J
TR3S250J
TR3S300J
TR4S150J
TR4S200J
TR4S225J
TR4S250J
TR4S300J
TR4S400J

150

J600

GO-135D

300

400

Frame
Type

Sensor Rating
(Amperes)

J600

600

K800

800

K1200

1200

Current Rating
(Amperes)

Rating Plug
Product Number

300
400
450
500
600
300
400
500
600
700
800

TR6S300J
TR6S400J
TR6S450J
TR6S500J
TR6S600J
TR8S300K
TR8S400K
TR8S500K
TR8S600K
TR8S700K
TR8S800K

600
800
1000
1200

TR12S600K
TR12S800K
TR12S1000K
TR12S1200K

Trip Unit Function Definitions
Short-Time (S)

Instantaneous (I)
Ground Fault (G)

Trip Indication Target (T1, T2)
Zone Selective Interlock (Z1, Z2)

Adjustable current setting
Adjustable long-time delay
Adjustable short-time pick-up
Adjustable short-time delay with l2t
Adjustable short-time delay without l2t
Adjustable pick-up
Adjustable ground fault pick-up
Adjustable ground fault delay with l2t
Adjustable ground fault delay without l2t
Overload/short circuit targets (T1)
Overload/short circuit/ground fault targets (T2)
Ground fault (Z1)
Ground fault/short-time (Z2)

MOLDED CASE
CIRCUIT BREAKERS

Long-Time (L)

3
MicroVersaTrip Trip Unit Selection

GO-135D
Targets

Trip Unit
Suffix
TS20LIT1
TS20LSIT1
TS20LIGT2
TS20LSIGT2
TS20LIGT2Z1
TS20LSIGT2Z1
TS20LSIGT2Z2

Zone Interlock

List
Price

Long-Time
(L)

Short-Time
(S)

Instantaneous
(I)

Ground Fault1
(G)

OL, SC
(T1)

OL, SC, GF
(T2)

GF
(Z1)

GF, ST
(Z2)

$755.00
$2120.00
$2380.00
$3745.00
$3965.00
$4330.00
$4915.00

•
•
•
•
•
•
•

–
•
–
•
–
•
•

•
•
•
•
•
•
•

–
–
•
•
•
•
•

•
•
–
–
•
–
–

–
–
•
•
–
•
•

–
–
–
–
•
•
–

–
–
–
–
–
–
•

1For single-phase, 3-wire or three-phase, 4-wire applications select appropriate neutral-current sensor from page 3-103.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-81
Prices and data subject to change without notice

Molded Case Circuit Breakers

Replacement Breakers
J and K Frame Circuit Breakers with Power+ 4 Trip Unit
Part Number Selection Instructions
1. Select product number of circuit breaker, including trip unit suffix.
2. Select lugs, internal/external accessories and neutral current sensor, as required from pages 3-85 through 3-104.
Power+ Trip Unit Characteristics
Current Setting
(Multiple of
Frame
Max.
Sensor Current
Sensor Current
Type Amperes Ratings (Amperes) Rating) (X)

Pick-up
(Multiple of
Current
Setting) (C)

.5, .6, .7, .8,
.9, .9.5, 1.0

J600

600

150, 200
300, 400,
500, 600

K1200

1200

800, 1000, 1200

Short-Time 1,2

Long-Time

(X) Fixed Sensor

.5, .6, .7, .8,
.9, .95, 1.0 (X)

Delay 3
(Seconds)

Pick-up
(Multiple of
Current
Setting) (C)

I 2t
Delay Ramp 3
(Seconds)

3, 6, 12, 25
Bands 1, 2, 3, 4

1.5, 2, 2.5, 3,
4, 5, 7, 9 (C)

.13, .26, .42
(Min, Int, Max)

Adjustable
Instantaneous
Pick-Up 1
(Multiple of
Sensor Current
Rating (X)

Pick-Up
(Multiple of
Sensor Current
Rating) (X)

1.5, 2, 3, 4,
5, 7, 9, 10 (X)

.2, .25, .3, .35,
.4, .45, .5, .6 (X)

Ground Fault 2

Delay 4
(Seconds)
0.10, 0.21
0.35
(Min, Int, Max)

1 When optional adjustable short-time pick-up is provided, instantaneous is fixed at 15X. Short-time and fixed instantaneous are not available on TJL

with 500A and 600A sensors.
2 Delay Curve = I 2 t in, I 2 t out
3 Time delay shown at 600% of current setting at lower limit of each band.
4 Time delay shown at lower limit of each band. All pick-up tolerances are ± 10%. Ground Fault Pick-up not to exceed 1200 amperes.

X = sensor current rating
C = current setting

Select trip unit product number from specific circuit breaker pages—J and K frames, page 3-81.
Circuit Breaker Product Number Selection (less lugs) 5,6
Standard Circuit Breaker

MOLDED CASE
CIRCUIT BREAKERS

Frame
Type

3

Base
Product No.

None

N

G

NG

Base
Product No.

None

N

G

NG

150

TJ4V2601A

$2703.00

$2703.00

$3909.00

$3909.00

THJ4V2601A

$3858.00

$3858.00

$5064.00

$5064.00

J600

K1200

Hi-Break

Current
Sensor
Ampere

List Price, GO-148D with Suffix

200

TJ4V2602A

$2703.00

$2703.00

$3909.00

$3909.00

THJ4V2602A

$3858.00

$3858.00

$5064.00

$5064.00

300

TJ4V2603A

$2703.00

$2703.00

$3909.00

$3909.00

THJ4V2603A

$3858.00

$3858.00

$5064.00

$5064.00

400

TJ4V2604A

$2703.00

$2703.00

$3909.00

$3909.00

THJ4V2604A

$3858.00

$3858.00

$5064.00

$5064.00

500

TJ4V2605A

$3657.00

$3657.00

$4863.00

$4863.00

THJ4V2605A

$4611.00

$4611.00

$5816.00

$5816.00
$5816.00

600

TJ4V2606A

$3657.00

$3657.00

$4863.00

$4863.00

THJ4V2606A

$4611.00

$4611.00

$5816.00

800

TK4V4608A

$4694.00

$4694.00

$5900.00

$5900.00

—

—

—

—

—

1000

TK4V4610A

$8183.00

$8183.00

$9389.00

$9389.00

—

—

—

—

—

1200

TK4V4612A

$8183.00

$8183.00

$9389.00

$9389.00

—

—

—

—

—

Circuit Breaker Product Number Selection (less lugs) 5,6

Power+ 4 Trip Unit Selection
Trip Unit
Functions

65 kAIC Breaker
Frame
Type

K1200

Suffix
None

W

G

NG

Adjustable Current Setting

•

•

•

•

Fixed Long-Time Pick-Up

•

•

•

•
•

Current
Sensor
Ampere

Base
Product No.

None

N

G

NG

150

TJL4V2601A

$4242.00

$4242.00

$5448.00

$5448.00

Fixed Long-Time Delay

•

•

•

200

TJL4V2602A

$4242.00

$4242.00

$5448.00

$5448.00

Long-Time Timing Light

•

•

•

•

300

TJL4V2603A

$4242.00

$4242.00

$5448.00

$5448.00

Adj. Short-Time Pick-Up

—

•

—

•

400

TJL4V2604A

$4242.00

$4242.00

$5448.00

$5448.00

Fixed Short-Time Delay I2t Ramp

—

•

—

•

500

TJL4V2605A2

$5071.00

7

$6275.00

7

•

—

•

—

600

TJL4V2606A2

$5071.00

7

$6275.00

7

800

TKL4V4608A

$5658.00

$5658.00

$6864.00

$6864.00

1000

TKL4V4610A

$9154.00

$9154.00

$10360.00

$10360.00

List Price, GO-148D with Suffix
Long-Time

J600

List Price, GO-148D with Suffix

1200

TKL4V4612A

$9154.00

$9154.00

$10360.00

Short-Time

Adj. Instantaneous Pick-Up
Instantaneous

$10360.00

Ground Fault5

Fixed Instantaneous Pick-Up7

—

•

—

•

Adj. Ground Fault Pick-Up
Zero Sequence

—

—

•

•

Adj. Ground Fault Delay

—

—

•

•

7 TJL4V with 500 and 600A sensors available with adjustable

5 For single-phase, 3-wire or three phase, 4-wire applications, select

instantaneous only.

appropriate neutral-current sensor from page 3-103.
6Select and price lugs and lug covers as required from pages 3-101 and 3-102.

• = Function included.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-82
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Internal Accessories
Spectra RMS Circuit Breakers

Universal Field-Installable Internal Accessories
All Spectra RMS circuit breakers from the SE150 through the SK1200, including
instantaneous-trip Mag Break motor circuit protectors and molded case switches, use
the same UL listed, field-installable internal accessories that do not require cover removal
to install.
Accessory Mounting
All accessories mount in pouches accessible from a front cover. All breakers have a left-side
pouch and right-side pouch. The following combinations may be installed:

Left Side Pouch

Left-Side Pouch—either shunt trip or undervoltage release plus bell alarm.
Right-Side Pouch—auxiliary switch (single or double pole).

Auxiliary Switch
GO-135S
Auxiliary switches provide remote indication of whether the circuit breaker main contacts
are opened or closed via open or closed SPDT switch elements.
Switch
Rating
5A @240 Vac/
0.5A @ 125 Vdc
Gold-Plated Contacts
0.5A @ 30V
One each
of above types

Number of
Switch Elements
1 form C
2 form C
1 form C
2 form C
2 form C

Auxiliary Switch
Product Number
SAUXPAB1
SAUXPAB2
SAUXGAB1
SAUXGAB2
SAUXGPAB2

List
Price
$149.00
$295.00
$149.00
$295.00
$295.00

Right Side Pouch

Red
White
Brown/white

Shunt Trip

MOLDED CASE
CIRCUIT BREAKERS

All accessory contacts shown
with the circuit breaker in
tripped position.

GO-135S

For remote tripping of breaker, use with momentary close contact. Not recommended for
use with latching relay contact since electronics in shunt trip will pulse power to the coil
if continuously energized, and breaker shunt tripping upon reclosure will be delayed 1-2
seconds at rated control voltage. (A short-circuit trip would be instantaneous.)

Auxilliary Switch

If maintained (latching relay) contact must be used and delayed shunt tripping is not
acceptable, use small bell alarm in series with control power for SE150 and SF250 frames
and auxiliary switch for SG600 and SK1200 breakers.
These devices are suitable for use with ground fault sensing and relaying equipment.
Maximum VA is 75. AC devices are UL listed for 50-60 Hz.
Voltage

Current (mA)

ac

dc

Inrush

Cont

Product
Number

List
Price

120
240
12
24
48

125
250
12
24
48

500
400
1000
300
300

6.0
5.0
800
10.0
10.0

SAST1
SAST2
SAST51
SAST3
SAST4

$363.00
$363.00
$363.00
$363.00
$363.00

1Not suitable for use with ground fault sensing and relaying equipment.

Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories.

Black
Black

All accessory contacts shown
with the circuit breaker in
tripped position.

Shunt Trip

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-83
Prices and data subject to change without notice

3

Molded Case Circuit Breakers

Internal Accessories
Spectra RMS Circuit Breakers

Undervoltage Release
GO-135S
The undervoltage release provides automatic circuit breaker tripping when there is a
power loss or major dip (to 35%-70% of rated voltage) in accessory control voltage. AC
devices are UL listed for 50-60 Hz. Product number SAUV1 may be used with time delay
unit SPUVTD (List Price $430.00, GO-245B) (delay 0.1 to 1.0 seconds), 120 Vac input, 125 Vdc
output.
Voltage
ac
120
240
24
48
120

Peak Current
(mA)
200
200
100
100

dc
125
250
24
48
125

Product
Number
SAUV1
SAUV2
SAUV3
SAUV4
SPUVTD

List
Price
$363.00
$363.00
$363.00
$363.00
$430.001

1GO-245B.

Undervoltage Release

Blue

All accessory contacts shown
with the circuit breaker in
tripped position.

Blue

Bell Alarm Switch
GO-135S
The bell alarm switch provides remote indication of whether the circuit breaker has been
tripped via open or closed SPDT switch elements, but remains unchanged during "On/Off"
circuit breaker operation and during operation by the "Push-to-Trip" button.

MOLDED CASE
CIRCUIT BREAKERS

Switch
Rating
5A @ 240 Vac/
0.5A @ 125 Vdc
Gold-Plated Contacts
0.5A @30V

Number of
Switch Elements

Product
Number

List
Price

1 form C

SABAP1

$154.00

1 form C

SABAG1

$154.00

Note: UL listed at 200,000 AIC without internal accessories, 100,000 AIC with internally mounted accessories.

Bell Alarm Switch

Purple
Yellow
Brown
All accessory contacts shown
with the circuit breaker in
tripped position.

3

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-84
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Internal Accessories
Molded Case Circuit Breakers
Pole Positions
L—Left
C—Center
R—Right
Lead Wire Exit
S—Side
B—Back

Accessory Devices and Ratings
Internally mounted accessories can be either factory or field
installed, but should be factory installed when UL listing is required.
F225 frame accessories, including THLC2, and THLC4 are UL listed
for field installation1.
Factory installed devices with leads exiting from the side are UL
listed, but when leads exit from the back the UL listing is void.
For accessory installation combinations refer to table below.
“Mounting Pole” refers to left-, center- or right-hand pole as seen
when facing the front of the breaker. Control leads may exit the
breaker from its side (S) or back (B) 2.

J Frame Circuit Breaker with Internal
Accessories Mounted in Each Pole

Nonautomatic circuit breakers (molded case switches) require
dummy trip units if internal accessories are to be field installed
(refer to page 3-91).

L

C

R

Inst.
Sheet
GEH-

TQB, THQB,
THHQB, TXQB,
TQL, THQL,
THHQL, TXQL,
TQC, THQC,
THHQC, TXQC

—

—

—

TQD, THQD

—

—

E150 TEB,
TEC, TED,
THED,
THLC1,
TB15,6,8

UL 7

F2259
TFC, TFJ, TFK,
THFK, THLC2,
THLC4, TLB2,
TLB4

R

Inst.
Sheet
GEH-

L

R

Inst.
Sheet
GEH-

—

—

—

—

—

—

One accessory only. Mounts
in a one-inch frame and
increase overall breaker size
by one pole. May be applied
to 1-, 2-, or 3-pole breakers.

4

—

—

—

—

—

—

One accessory only

UL

3418
Aux
3416
S.T.

—

UL

3417

—

UL8

3434

2-pole circuit breaker—any
one 3-pole circuit breaker—
any two except UVR and
3-coil shunt trip

UL

UL

4653

UL

UL

4653

UL8

UL

4622

any two

3320

UL

UL

3321
Aux
3435
S.T.

—

UL

5407

UL8

—

3346

Any two plus belt alarm except
TB4, TBC4 any one plus bell
alarm.

—

4305

UL

UL

3321
Aux
3344
S.T.

—

UL

5408

UL8

—

3346

Any two plus bell alarm

—

4626

—

UL

4623
Aux
4623
S.T.

—

UL

4623

—

—

—

Any one plus bell alarm

Mounting Pole
L

R

—

UL

—

—

—

—

UL

—

UL

4576

UL 7

—

—

UL

4620

J600 TJC,
TJD, TJJ,
TJK, THJK,
TB45, TBC45

—

UL8

—

K1200 TKC,
TKM, THKM
TB65, TBC65,
TB8, TBC8

—

UL8

TJ4V, TKL4V,
TJH6S, TKL12S 8
solid-state trips

—

UL

Inst.
Sheet
GEH-

Three Coil
Shunt Trip

L

Mounting Pole
Breaker Type

Undervoltage
Release

4

Mounting Pole

Mounting Pole

Red
White
Brown/white
Accessory-Lead
Color Coding10

Purple
Yellow
Brown
Bell Alarm Switch

3

Red
Brown/white
Blue
White

Auxiliary Switch

Black

Blue

Black

Blue

Shunt Trip

Total Number of
Accessories Within any
One Circuit Breaker

Undervoltage Release

All accessory contacts shown
with the circuit breaker in
tripped position.

Yellow
Black
Three-Coil Shunt Trip

1 Except TFC and TFJ, F225 line model 4 frames and trips (mfg. code date J101+ (1981 or later), and THLC2, THLC4, TLB4 are UL listed for

field installation of most accessories.

2 Not UL listed.
3 600 Vac auxiliary switches are not UL listed.
4 Accessories are factory installed only.
5 UL listed at 200 AIC without internal accessories, 100 AIC with internally mounted accessories.
6 Accessories not available for single-pole TEB/TED frame. Use two-pole circuit breaker.
7 Left pole mounting not available for two-pole TEB, TED.
8 Not available with lead exit from the back of breaker.
9 UL listed interrupting capacity with accessories: 10 kAIC at 600 Vac, 22 kAIC at 480 Vac, 22 kAIC at 240 Vac.
10Leads are #18 125°C Vulkene insulated.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

MOLDED CASE
CIRCUIT BREAKERS

Auxiliary Switch 3
or Shunt Trip

Bell Alarm Switch

3-85
Prices and data subject to change without notice

Molded Case Circuit Breakers

Internal Accessories
Internally Mounted Signaling and Controlling Functions

How to Order
For factory installation, specify breaker product number, accessory base number, and
appropriate suffix. (Example: Product Number TJK436125WL, TJUV1RS, TJKASA2AB2LS
specifies a type TJK breaker with factory installed undervoltage release in the right-hand
pole and an auxiliary switch in the left-hand pole.)
For field replacement, order the accessory by the base number only.
Where this number ends in "R" or "L" right-hand and left-hand devices are physically
different. Specify only one suffix letter per accessory product number when option is
available.
Nonautomatic circuit breakers require dummy trip units if internal accessories are
to be mounted.
Undervoltage Release

Mine Duty Circuit Breaker Undervoltage Release
Circuit Breaker
Frame

E

MOLDED CASE
CIRCUIT BREAKERS

J

K

GO-135A

Control
Voltage

Factory Installed1
Product Number
Premium Duty

List
Price

Field Replacement
Product Number2

List
Price

24 Vac
120 Vac
240 Vac
12 Vdc
24 Vdc
60 Vdc
24 Vac
120 Vac
230 Vac
12 Vdc
24 Vdc
60 Vdc
24 Vac
120 Vac
240 Vac
12 Vdc
24 Vdc
60 Vdc

TEDMDVAS
TEDMDVBS
TEDMDVCS
TEDMDVDS
TEDMDVES
TEDMDVFS
TJMDVAS
TJMDVBS
TJMDVCS
TJMDVDS
TJMDVES
TJMDVFS
TKMDVAS
TKMDVBS
TKMDVCS
TKMDVDS
TKMDVES
TKMDVFS

$485.00
$485.00
$485.00
$485.00
$485.00
$485.00
$509.00
$509.00
$509.00
$509.00
$509.00
$509.00
$509.00
$509.00
$509.00
$509.00
$509.00
$509.00

TEMDVAS
TEMDVBS
TEMDVCS
TEMDVDS
TEMDVES
TEMDVFS
TJRMDVA
TJRMDVB
TJRMDVC
TJRMDVD
TJRMDVE
TJRMDVF
TKRMDVA
TKRMDVB
TKRMDVC
TKRMDVD
TKRMDVE
TKRMDVF

$485.00
$485.00
$485.00
$485.00
$485.00
$485.00
$526.00
$526.00
$526.00
$526.00
$526.00
$526.00
$526.00
$526.00
$526.00
$526.00
$526.00
$526.00

1Mounts in right pole only. "S" suffix–wires out the side of breaker.
2Replacement for standard and premium duty mine duty UVR, both old and new design.

3

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-86
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Internal Accessories
Internally Mounted Signaling and Controlling Functions

Auxiliary Switches
Unless otherwise noted switch is SPDT rated 6 amperes at rated ac voltage, 1/2 amperes at 125 Vdc, 1/4 amperes at 250 Vdc.

TQB, THQB, THHQB, TXQB, TQL,2
THQL, THHQL, TXQL
TQC, THQC, THHQC, TXQC2
TQD, THQD
TEB, TEC, TB1
TED, THED,THLC18
TFC, TFJ, TFK, THFK,9
THLC2, THLC4, TLB2, TLB4
TJC, TJD, TJJ, TJK, THJK

TB4, TBC4

TKM, THKM, TKC, TB6,
TB8, TBC6, TBC8
TJ4V/TJL, TK4V/TKL

TRL/TRP
R Frame

Base
Number

13

TQAS2A14

5

$64.50

13

TQCAS2A14

5

1
1
2
1
2
1
2
3
4
1
2
3
4
1
2
3
4
2
4
1
2
3
4
5
6
7
8
9
10
11
12

TQDAS2AB1RS
TEDAS2AB1R,L7,8
TEDAS2AB2R,L7,8
TFKASA2AB110
TFKASA2AB210
TJKASA2AB1R,L
TJKASA2AB2R,L
TJKASA2AB3R,L
TJKASA2AB4R,L
TB4ASA2AB1R,L
TB4ASA2AB2R,L
TB4ASA2AB3R,L
TB4ASA2AB4R,L
TKMAAS2AB1
TKMAAS2AB2
TKMAAS2AB3
TKMAAS2AB4
TVAS2AB2R10
TVAS2AB4R10
TPAS2AB110
TPAS2AB210
TPAS2AB310
TPAS2AB410
TPAS2AB510
TPAS2AB610
TPAS2AB7S10
TPAS2AB8S10
TPAS2AB9S10
TPAS2AB10S10
TPAS2AB11S10
TPAS2AB12S10

$77.50
$148.006
$148.00
$295.00
$148.00
$295.00
$148.00
$295.00
$439.00
$598.00
$148.00
$295.00
$439.00
$598.00
$148.00
$295.00
$439.00
$598.00
$297.0011
$553.0011
$251.0012
$503.0012
$534.0012
$562.0012
$623.0012
$680.0012
$924.0012
$1180.0012
$1215.0012
$1240.0012
$1300.0012
$1365.0012

Must
Must
Must
Must
Must
Must

N/A
S
S
RS or LS
RS or LS
S
S
S
S
S
S
S
S
RS or LS
RS or LS
RS or LS
RS or LS
S
S
S
S
S
S
S
S
be Factory Installed
be Factory Installed
be Factory Installed
be Factory Installed
be Factory Installed
be Factory Installed

Control Voltage 600 Vac, 250 Vdc Maximum
Not UL Listed Suffix1
Add to Base Product
Base
Number for Factory
List
Number
Installation
Price
–

–

–
–
TEDAS6AB1R,L7,8
TEDAS6AB2R,L7,8
TFKASA6AB110
TFKASA6AB210
TJKASA6AB1R,L
TJKASA6AB2R,L
TJKASA6AB3R,L
TJKASA6AB4R,L
TB4ASA6AB1R,L
TB4ASA6AB2R,L
TB4ASA6AB3R,L
TB4ASA6AB4R,L
TKMAAS6AB1
TKMAAS6AB2
TKMAAS6AB3
TKMAAS6AB4
TVAS6AB2R
TVAS6AB4R
TPAS6AB1
TPAS6AB2
TPAS6AB3
TPAS6AB4
TPAS6AB5
TPAS6AB6
TPAS6AB7S
Must
TPAS6AB8S
Must
TPAS6AB9S
Must
TPAS6AB10S
Must
TPAS6AB11S
Must
TPAS6AB12S
Must

–
–
S
S
RS
RS
S
S
S
S
S
S
S
S
RS or LS
RS or LS
RS or LS
RS or LS
S
S
S
S
S
S
S
S
be Factory Installed
be Factory Installed
be Factory Installed
be Factory Installed
be Factory Installed
be Factory Installed

–
–
$179.00
$360.00
$167.00
$360.00
$179.00
$360.00
$530.00
$712.00
$179.00
$360.00
$530.00
$712.00
$179.00
$360.00
$530.00
$712.00
$341.0011
$657.0011
$251.0012
$503.0012
$534.0012
$562.0012
$623.0012
$680.0012
$924.0012
$1180.0012
$1215.0012
$1240.0012
$1300.0012
$1365.0012

1"S" suffix for wires out the side of breaker. For lead exit from back of breaker, replace suffix "S" with "B"" and multiply list price by 1.25. "B" suffix not UL listed. Not available with

leads out the back for "Q Line".
2Not available on GFCI (5 ma) or Equipment Ground Fault (30 ma) breakers.
3Switch is SPST. Operates like "A" side of an "AB" contact and is rated six amperes at 120 Vac and three amperes at 24 Vac.
4Accessories mounted in a one-inch frame and increase overall breaker size by one pole added to left side. May be applied to 1-, 2-, or 3-pole breakers. Must be factory installed.

MOLDED CASE
CIRCUIT BREAKERS

Breaker Type

Number of
SPDT Switch
Elements

Control Voltage 240 Vac, 250 Vdc Maximum
UL Listed When Factory Installed Suffix1
Add to Base Product
Number for Factory
List
Installation
Price

GO-135B

Maximum total breaker width is four poles.
5To order, specify both the accessory and breaker product number, e.g. THQL2130, TQASA1 identifies a 30 ampere, 2-pole plug-in breaker with a factory installed SPST

auxiliary switch.
6GO-135F.
7Auxiliary switch mounts in right pole only on two-pole TEB, TED breakers. (Factory installed only.)
8Not available with “B” suffix–leads out back.
9Changes circuit breaker interrupting capacity to 10kAIC, 600 Vac; 22 kAIC, 240 and 480 Vac.
10UL listed for field installation.
11GO-135C.
12GO-145A.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-87
Prices and data subject to change without notice

3

Molded Case Circuit Breakers

Internal Accessories
Internally Mounted Signaling and Controlling Functions

How to Order
For field replacement, order base number only. For factory installation, order base number
plus appropriate suffix. For a nonautomatic breaker (molded case switch) a dummy trip is
required when installing either a shunt trip or UVR.
Shunt Trip
Remote Tripping – Trips breaker by remote control. Trip coil de-energized when breaker
opens. Device meets UL requirements for service to ground fault system.
Undervoltage Release
Undervoltage release automatically trips breaker when applied coil voltage drops to 30 to 70
percent of rated value. Time-delay unit prevent nuisance tripping due to momentary loss of
voltage. Separate externally mounted unit has 120 Vac input and 125 Vdc output. Used in
conjunction with 125 Vdc undervoltage release which must be ordered separately. Product
number SPUVTD for adjustable delay .1 to 1.0 seconds. List Price $430.00 GO-245B.
Shunt Trip

GO-135B
Accessory Voltage
Vac
Vdc

Breaker Type
TQB, THQB, THHQB, TXQB,
TQL, THQL, THHQL, TXQL

12
24-48
120
240
12
24
120
240
480
600

TEB, TEC, TB1-B,11
TED, THED, THLC1

MOLDED CASE
CIRCUIT BREAKERS

TQSTA14,5,6,7
TQSTA74,6,7
TQSTA84,6,7
TQDSTA8,9
TQDSTA29
TQDSTA79
TQDSTA89
TEDST12
TEDST12
TEDST13
TEDST13
TEDST7
TEDST8
TEDST9
TEDST12
TEDST11
TFKSTA121
TFKSTA121
TFKSTA131
TFKSTA131
TFKSTA71
TFKSTA81
TFKSTA91
TFKSTA121
TFKSTA111

120-240

TQD, THQD

3

Product Number1,2 — UL Listed When Factory Installed
Suffix Number3
Base Number
Add to Base Product Number
for Field Replacement
for Factory Installation

12
24
48
125
250

TFC, TFJ, TFK, THFK, THLC2,
THLC4, TLB2, TLB4

120
240
480
600
12
24
48
125
250

10
10
10
10
10
10
10

RS or LS8,12
RS or LS8,12
RS or LS8,12
RS or LS8,12
RS or LS8,12
RS or LS8,12
RS or LS8,12
RS or LS8,12
RS or LS8,12
RS or LS
RS or LS
RS or LS
RS or LS
RS or LS
RS or LS
RS or LS
RS or LS
RS or LS

List
Price
$95.50
$95.50
$95.50
$178.00
$178.00
$178.00
$178.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00

1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines, order Product Number

192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed.

Not available with leads out the back on "Q Line."
4Mounts on a one-inch frame and increases overall breaker size by one pole added to left side. May be applied to 1-, 2-, or 3-pole breakers. Maximum total breaker width is 4-pole.

Must be factory installed.
5A selective listing of breaker product numbers that include 120 Volt ac shunt trip appears on page 3-14.
6Not available on GFCI (5 ma) or Equipment Ground Fault (30 ma) breakers.
7TQST shunt trips not available on breakers over 100 A.
8Not available with “B” suffix–leads out back.
9Must be factory installed, right pole only.
10To order, specify both the accessory and breaker product number =, e.g.THQL2130, TQST1 identifies a 30 A, 2-pole plug-in breaker with a factory installed 120 Vac shunt trip.
11For TB1 with bolt-on limiters.
12Mounts in the right pole only on 2-pole TEB, TED breakers.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-88
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Internal Accessories
Internally Mounted Signaling and Controlling Functions

Shunt Trip (continued)

GO-135B

Vac

Vdc

120
240
480
600
TJC, TJD, TJJ, TJK, THJK

12
24
48
125
250
120
240
480
600

TB4, TBC4

TKC, TKM, THKM, TB6,
TB8, TBC6, TBC84

TJ4V, TKL4V,
TJH6S, TKL12S

R Frame
TRL, TRP

12
24
48
125
250
120
240
480
600
12
24
48
125
250
120
240
480
600
12
24
48
125
250
120
240
480
600
12
24
48
125
250

TJKSTA12R,L
TJKSTA12R,L
TJKSTA13R,L
TJKSTA13R,L
TJKSTA7R,L
TJKSTA8R,L
TJKSTA9R,L
TJKSTA12R,L
TJKSTA11R,L
TB4STA12R,L
TB4STA12R,L
TB4STA13R,L
TB4STA13R,L
TB4STA7R,L
TB4STA8R,L
TB4STA9R,L
TB4STA12R,L
TB4STA11R,L
TKMASTA12R,L
TKMASTA12R,L
TKMASTA13R,L
TKMASTA13R,L
TKMASTA7R,L
TKMASTA8R,L
TKMASTA9R,L
TKMASTA12R,L
TKMASTA11R,L
TVST12R
TVST12R
TVST13R
TVST13R
TVST7R
TVST8R
TVST9R
TVST12R
TVST11R
TPST12R
TPST12R
TPST13R
TPST13R
TPST7R
TPST8R
TPST9R
TPST12R
TPST11R

List
Price

S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S

$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.005
$363.005
$363.005
$363.005
$363.005
$363.005
$363.005
$363.005
$363.005
$630.006
$630.006
$630.006
$630.006
$630.006
$630.006
$630.006
$630.006
$630.006

1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1. for 120 Vac UVRs on all other breaker lines, order Product Number

192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed. Not

available with leads out the back on "Q Line."
4Not UL listed.
5GO-135C UL listed for field installation.
6GO-145A UL listed for field installation.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-89
Prices and data subject to change without notice

MOLDED CASE
CIRCUIT BREAKERS

Accessory Voltage
Breaker Type

Product Number1,2 — UL Listed When Factory Installed
Suffix Number3
Base Number
Add to Base Product Number
for Field Replacement
for Factory Installation

3

Molded Case Circuit Breakers

Internal Accessories
Internally Mounted Signaling and Controlling Functions

UnderVoltage Release

GO-135B
Accessory Voltage

Breaker Type

Vac

Vdc

Product Number1,2 — UL Listed When Factory Installed
Suffix Number3
Base Number
Add to Base Product Number
for Field Replacement
for Factory Installation

120
240
480
600

TEB, TEC, TB1-B5
TED, THED, THLC1

TEDUV1
TEDUV2
TEDUV4
TEDUV6
TEDUV7
TEDUV8
TEDUV9
TEDUV10
TEDUV11
TFKUVA11
TFKUVA2
TFKUVA4
TFKUVA6
TFKUVA7
TFKUVA8
TFKUVA9
TFKUVA10
TDKUVA11
TJUV1R
TJUV2R
TJUV4R
TJUV6R
TJUV7R
TJUV8R
TJUV9R
TJUV10R
TJUV11R
TKUV1R
TKUV2R
TKUV4R
TKUV6R
TKUV7R
TKUV8R
TKUV9R
TKUV10R
TKUV11R
TVUV1R
TVUV2R
TVUV4R
TVUV6R
TVUV7R
TVUV8R
TVUV9R
TVUV10R
TVUV11R
TVUV3R
TPUV1
TPUV2
TPUV4
TPUV6
TPUV7
TPUV8
TPUV9
TPUV10
TPUV11

12
24
48
125
250

TFC, TFJ, TFK, THFK, THLC2,
THLC4, TLB2, TLB4

120
240
480
600
12
24
48
125
250
120
240
480
600

TJC, TJD, TJJ, TJK, THJK

120
240
480
600

MOLDED CASE
CIRCUIT BREAKERS

TKC, TKM, THKM, TB6,
TB8, TBC6, TBC86

3

12
24
48
125
250

12
24
48
125
250
120
240
480
600

TJ4V, TKL4V,
TJH6S, TKL12S5

12
24
48
125
250
380
120
240
480
600

R Frame
TRL, TRP5

12
24
48
125
250

RS8
RS8
RS8
RS8
RS8
RS8
RS8
RS8
RS8
RS or LS
RS or LS
RS or LS
RS or LS
RS or LS
RS or LS
RS or LS
RS or LS
RS or LS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S

List
Price
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.00
$363.007
$363.007
$363.007
$363.007
$363.007
$363.007
$363.007
$363.007
$363.007
$363.007
$630.008
$630.008
$630.008
$630.008
$630.008
$630.008
$630.008
$630.008
$630.008

1UL listed for field installation on TFC, TFJ, TFK, and THFK model 4 frames and trips (mfg. Code date J101 or later) and on THLC2, THLC4, TLB4.
2For replacement voltage suppressor on 120 Vac UVRs for F225 line, order Product Number 286A8062G1 for 120 Vac UVRs on all other breaker lines, order Product Number

192A8300G1.
3"S" suffix for wires out the side of the breaker. For lead exit from back of breaker, replace suffix "S" with "B", and multiply "S" accessory List Price by 1.25. "B" suffix not UL listed. Not

available with leads out the back on "Q Line."
4For TB1 with bolt-on limiters.
5Not available with “B” suffix – leads out back.
6Not UL listed.
7GO-135C UL listed for field installation.
8GO-145A UL listed for field installation.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-90
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Internal Accessories
Internally Mounted Signaling and Controlling Functions

GO-135B

Automatically trips breaker when an undervoltage or power outage
condition occurs. Special PUSH-TO-TRIP/PUSH-TO-RESET button is
used to manually trip the breaker (E-frame only). On J and K frames,
the UVR is handle resettable with a cover-mounted button to provide
local mechanical tripping.
The Heavy-Duty Undervoltage Release (UVR) is designed for
applications where repeated UVR trips are anticipated. The manual
reset feature prevents breaker reset or possible contact kiss until
power is available and reset button is depressed.
Mounts in right pole of breaker only. Must be factory installed to
incorporate special breaker frame modifications.2 Motor-operated
mechanism cannot be provided when heavy-duty UVR is installed.

TEB, TED, THED,
TEC,TB14,5

TJJ, TJK, THJK, TJD,
TJC, TB4, TBC4

TKM, THKM, TKC,
TB6,TB8, TBC66,
TBC86

ac

dc

Product Number3

List Price

24
120
240
–
–
–
–
24
120
240
–
–
–
24
120
240
–
–
–

–
–
–
12
24
60
125
–
–
–
12
24
60
–
–
–
12
24
60

TEDXUVARS13
TEDXUVBRS13
TEDXUVCRS13
TEDXUVDRS13
TEDXUVERS13
TEDXUVFRS13
TEDXUVGRS13
TJMDVAS
TJMDVBS
TJMDVCS
TJMDVDS
TJMDVES
TJMDVFS
TKMDVAS
TKMDVBS
TKMDVCS
TKMDVDS
TKMDVES
TKMDVFS

$543.00
$543.00
$543.00
$543.00
$543.00
$543.00
$543.00
$509.007
$509.007
$509.007
$509.007
$509.007
$509.007
$509.007
$509.007
$509.007
$509.007
$509.007
$509.007

GO-135B
Product Number
UL Listed When Factory Installed
Base No.
Suffix

Breaker
Type
TEB, TEC, TB1
TED, THED, THLC1
TFC, TFJ, TFK, THFK,
THLC2, THLC4, TLB4
TJC, TJJ, TJK, THJK
TB4, TBC4, TJD
TKC, TKM, THKM,
TB6, TBC6, TBC8, TB8

List Price

TEDBAR or
TEDBAL5,8

S

$154.00
$154.00

TFKBAAR9,10

S

$154.00

TJKBAAL11

S

$156.00

TKMABAAL11

S

$141.00

TJL, TKL

TJVBALS
TKVBALS

S

$156.0012
$156.0012

(R Frame)
TRL, TRP

TPSBAS

S

$259.0013

Blown Fuse Detector-Three-Coil Shunt Trip

GO-135B

Product Number
UL Listed When Factory Installed
Base No.
Suffix

Breaker
Type

Voltage
Breaker Type

Bell Alarm Switches

TED, THED, TEC5
TFJ, TJK, THFK, TFC
TJJ, TJK, THJK, TJD, TJC
TKM, THKM, TKC
(R Frame) TRL, TRP

TEDST316
TFKBFD316
TJKST316
TKMAST316
TPST316

RS
LS or RS
LS
LS
S

Dummy Trip1

$672.00
$672.00
$672.00
$672.00
$1530.0013

GO-135B

Breaker Type
E150
FJ225
JJ400
FK225
FK225
JK400
JK600
KM800
KM1200

List Price

Product Number

List Price

Internal accessories for these noninterchangeable
breakers require factory-installed dummy trips.
Automatically supplied when accessories are ordered.
TFKYT2 (two-pole)
TFKYT3 (three-pole)
TJKYT3 (two-pole, three-pole)
TJKYT36 (two-pole, three-pole)
TKMAYT3 (two-pole, three-pole)
TKMA3YT12 (two-pole, three-pole)

No
Charge
$148.00
$208.00
$212.00
$212.00
$261.00
$424.00

1Not UL listed when field installed.
2For replacement purposes, order from page 3-84 using field replacement Product

Number.
3Add "B" suffix for leads exit from back of breaker; for price, multiply List Price by 1.25.

MOLDED CASE
CIRCUIT BREAKERS

Heavy-Duty Undervoltage Release1

4For TB1 with bolt-on limiters.
5Not available with “B” suffix – leads out back.
6Not UL listed.

3

7GO-135A.
8Not available for two-pole TEB, TED. Order TEDBAR.
9Changes circuit breaker interrupting capacity to: 10kA @ 600 Vac, 22kA @ 480 Vac,

22kA @ 240 Vac, for TFC, TFJ, TFK and THFK only.
10UL listed for field installation.
11Mounts in center pole with leads out left side.
12GO-135C.
13GO-145A.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-91
Prices and data subject to change without notice

Molded Case Circuit Breakers

External Accessories
Cable Operators

Spectra Flex Cable Operators
—UL Listed—File E–57253
—Reduced installation costs:
—Simpler, faster installation
—No special alignment required
—Optimized panel layout:
—Breaker mounting position is independent of flange-mounted
handle location
—Covers a full spectrum of enclosure types and sizes:
—Flange-mounted handle for NEMA Types 1, 3R, 12 and 13
enclosures
—Flange-mounted handle for NEMA 4/4X enclosures—optional
—Broad range of enclosure sizes and breaker mounting
configurations
—8 different operating cable lengths available from 3 to 10 feet
—For circuit breaker types E150, SE150, SF250, SG600 and SK1200
—Force and motion transmitted independently of breaker
mounting plane or position relative to handle location
—Common breaker mounted operator for SE150 and SF250 frames

MOLDED CASE
CIRCUIT BREAKERS

Spectra Flex cable operating mechanisms are suitable for
application with GE circuit breakers mounted in a wide variety of
flanged enclosure types and sizes.

3

Flange-mounted handle mechanisms are available for NEMA Types
1, 12 or 13 enclosures in either 6 inch (Model SCH1) or 10 inch
(Model SCH2) handle lengths. Corresponding mechanisms, SCH1X
and SCH2X, are available for NEMA Type 4/4X enclosures. Handle
mechanisms are suitable for either left or right flange operation.
The handle mechanism is combined with one of eight operating
cables, with lengths from 3 to 10 feet, to cover a broad range of
possible breaker mounting locations in the enclosure. The cable
links the handle mechanism to the breaker-mounted operating
mechanism and transmits the mechanical force and motion of the
handle mechanism to the breaker mounted mechanism. The force
and motion is transmitted independently of the breaker mounting
plane or location relative to the location of the handle mechanism,
provided only that the bending radius of the cable is not less than
3 inches. No mounting reinforcement of the breaker or enclosure
flange is required.
The breaker-operating mechanism mounts directly to the face of
the breaker and does not involve any mounting interface with the
enclosure. A standard breaker mounting screw kit for tapped holes
is furnished with each mechanism to mount the breaker in the
enclosure.
See page 3-93 for ordering and pricing information.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-92
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

External Accessories
Cable Operators

How to order
Use the circuit breaker mounting zone dimension table to determine the correct cable length
for the application and ensure that the 3-inch minimum bending radius is not violated. Select
the breaker mounted mechanism, operating cable and handle mechanism below. Order as
separate components.

Publication References
Breaker types E150, SE150, SF250, SG600
Breaker type SK1200

GEH-6290
GEH-6291

See Section 21 for publication ordering information.

Maximum Dimensions in Inches
To determine the maximum mounting dimensions for 60-through 120-inch-long operating
cables, add the respective additional lengths to the 48-inch cable maximum dimensions.
(Example: Add 12 inches to E, F and G dimensions for 60-inch cable length.) When cable is
installed, the minimum cable bend radius should not be less than 3 inches. The minimum
cable bending requirement must be met to ensure a safe operating environment.

Maximum Mounting Dimensions (in.)

8"
10"
12"
16"
18"
20"
24"

E1

36" Cable
F

G

13.5
13.0
12.8
10.5
8.5
–
–

4.0
5.0
6.0
4.5
3.5
0.5
–

15.0
14.8
14.5
14.2
12.6
10.0
–

Operating Cables
E1

48" Cable
F

G

25.5
25.0
24.8
22.5
20.5
22.0
19.5

16.0
17.0
17.0
16.5
15.5
15.0
14.0

27.0
26.8
26.5
26.2
24.6
24.0
22.0

GO-144A
Circuit Breaker Type

Cable
Length
3'
4'
5'
6'
7'
8'
9'
10'

1Maximum E Dimension only if F = 4.5"

E150, SE150, SF250, SG600
Product
List
Number
Price
SC3L
SC4L
SC5L
SC6L
SC7L
SC8L
SC9L
SC10L

$91.00
$108.00
$119.00
$134.00
$148.00
$163.00
$196.00
$211.00

SK1200
Product
Number

List
Price

SC3H
SC4H
SC5H
SC6H
SC7H
SC8H
SC9H
SC10H

$119.00
$141.00
$163.00
$185.00
$207.00
$229.00
$251.00
$273.00

Breaker and Handle Mechanisms
Flange-Mounted Handle Mechanism
Circuit
Breaker
Type
E150
SE150
SF250
SG600
SK1200

Breaker Mounted
Mechanism
Product
List Price
Number
GO-144A
SCOM1A
SCOM1EF
SCOM1EF
SCOM1G
SCOM1K

$96.00
$133.00
$133.00
$148.00
$149.00

6"
Product
Number

NEMA Enclosure Type 1, 3R, 12, 13
10"
List Price
Product
GO-144A
Number

NEMA Enclosure Type 4, 4X
6"

10"

List Price
GO-144A

Product
Number

List Price
GO-144A

Product
Number

List Price
GO-144A

SCH1

$188.00

SCH2

$322.00

SCH1X

$258.00

SCH2X

$373.00

–

–

SCH2K

$322.00

–

–

SCH2KX

$373.00

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

MOLDED CASE
CIRCUIT BREAKERS

Box
Depth

Circuit Breaker Mounting Zone Dimensions

3-93
Prices and data subject to change without notice

3

Molded Case Circuit Breakers

External Accessories
Flange-Mounted Operators
Type STDA Flange Handles and Variable Depth Operating
Mechanisms
—Designed to meet automotive duty specifications
—NEMA 12/13 and 4/4X UL Component Recognized components,
File E-57253l CSA LR 10263
—For right or left hand flange mounting – field convertible
—Mounting dimensions to fit standard flange enclosures 8 inches –
24 inches deep
—Detailed installation instructions
—Superior strength
Flange Handle Construction
—Rugged die cast housing with provisions for locking in OFF position
with up to three 3/16-inch to 5/16-inch padlocks
—O-ring seals for dirt-tight/oil-tight duty
—Gusseted, 3/32-inch thick double-sided steel handle with large,
red-black self-extinguishing grade plastic grip.

Flange Stiffener Kit or Extended Length Drive Rod,
Product Number TDSR

Provides rigid 3/8-inch diameter rod between STDA handle mounting
surface (flange or center mullion) and operating mechanism when
STDA handle would otherwise not be rigidly supported.
Rod length is 22 inches and my be cut to appropriate length. Also
used as extended-length drive rod for SDOM1A and SDOM3 when
standard 16 inch rod is not long enough. (Operating mechanism
Product Number SDOM6 for SK1200 includes two 22" unique
3/8-16x22 inch flange stiffener rods, Product Number TDSR and
drive rod.)
Operating
Mechanism
Product Number

GO-144A

Product Number STDA1 (6 inch) and STDA2 (10 inch) flange series
handles are interchangeable. While the SE150 through SG600
operating mechanisms can be easily operated with the 6-inch STDA1
handle, the 10-inch STDA2 may be used to obtain lower operating
force and/or to provide a proportionally larger handle on large
enclosures. STDA3 and STDA3X can be used only with SDOM6 (for
SK1200) operating mechanism.

MOLDED CASE
CIRCUIT BREAKERS

NEMA 12/13
Flange Handle
Product Number

3

STDA1
STDA2
STDA3

List
Price

NEMA 4/4X
Flange Handle
Product Number

List
Price

Nominal
Length
Inches

Installation
Instruction
Number

Drilling
Template
Number

$82.50
$94.50
$94.50

STDA1X
STDA2X
STDA3X

$148.00
$165.00
$165.00

6
10
10

GEH-5314

GEH-5314

Operating Mechanism Selection
Circuit Breaker
Type

Flange Handle
Product Number

SE150
SF250
SG600
SK12001
TEB, TED, THED, TEC
TB1 (150A),
TEC with TECL
THLC1 (150A)
TFJ, TFK, TFC (225A)
J-Frames, TJC
(400, 600A)3
TB4 (400A) TJH/TJL4
(600A Max)
K-Frames, TKC
(800A, 1200A)5,
THLC2 (225A), THLC4
TLB4 (400A)
TB6 (600A), TB8 (800A)
TKH/TKLD6 (1200A Max)

GO-144A
Operating Mechanism
Product Number

STDA1, 1X (6 inch)
or
STDA2, 2X (10-inch)
STDA3, 3X

STDA1, 1X (6 inch)
or
STDA2, 2X (10-inch)

List
Price

SDOM1A
SDOM3
SDOM4
SDOM61
SDOM1A
SDOM1A
SDOM1AP
TDOM1D
TDOM32

$67.00
$76.50
$194.00
$303.00
$67.00
$67.00
$15.00
$252.00
$76.50

TDOM4

$194.00

TDOM5

$265.00

TDOM6

$303.00

TDOM7

$303.00

Flange
Stiffener Kit
Product Number

Extended
Drive Rod
Product Number

List
Price

TDSR

TDSR

$29.50

TDSR1

$28.00

SDOM1A, SDOM3,
TDOM1A through TDOM3

TDSR

SDOM4,

Flange Handle Selection

GO-144A

TDOM4 through TDOM7

(16" supplied with
operating mechanism)

Extended Drive Stud, Product Number TDS1, TDS2

GO-144A

This optional drive study permits locating the operating mechanism
1-5/16 inches farther to the left (When flange handle is on right side)
or to the right (when handle is on the left side) to accommodate
specific mounting restrictions. Not suitable for use with SDOM4,
SDOM6, TDOM4 and TDOM5 operating mechanisms.
Operating Mechanism
Product Number
SDOM1A, SDOM3,
TDOM1A through TDOM3
TDOM6, TDOM7

Extended Drive Stud
Product Number

List
Price

TDS1

$29.50
$29.50

TDS2

Door Hardware NEMA 12/13 and 4/4X

GO-144A

Type TDV door hardware provides sealing and interlocking of 3/4-inch
nominal door depth hinged on left or right. Interlocking design
requires use of screwdriver to release. When used with an STDA
flange handle and operating mechanisms, disconnect or circuit
breaker cannot be turned on unless door and door hardware have
been closed. For noninterlocking type, one bracket in kit is not used.
Use of third point latch recommended for doors 40 inches or longer.

Description
NEMA 12/13 two point
interlocking door hardware kit
NEMA 4/4X two point
interlockingdoor hardware kit
Third point latch kit for above

Door Hinged
on Left
Product Number

Door Hinged
on Right
Product Number

List
Price

TDV1

TDV1L

$134.00

TDV1X

TDV1LX

$174.00

TDV3

TDV3L

$29.50

1Requires STDA3 or STDA3X (10 inch, SK1200 only).
2Not suitable for left hand mounting.
3Includes TJ/THJ/TJL with MicroVersaTrip R trip unit.
4Use TDOM5 for TJH/TJL with MicroVersaTrip R RMS-9 trip unit.
5Includes TK/TKL with MicroVersaTrip R trip unit.
6Use TDOM7 for TKH/TKL with MicroVersaTrip R trip unit.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-94
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

External Accessories
Flange-Mounted Operators
Auxiliary Contact Kits
Available SPDT and DPDT and actuated by operating mechanism yoke.
Used With
Operating Mechanism
Product Number

When STDA
handle is on
Right
Left
Flange
Flange

SDOM1A,
SDOM3
SDOM4
TDOM1A, JA
TDOM1B, JB
TDOM1C
TDOM1D
TDOM3
SDOM6
TDOM4
TDOM5
TDOM6
TDOM7

•

•

•
•

GO-144A

Auxiliary Contact Kit
SPDT

DPDT

Product
Number

List
Price

Product
Number

List
Price

TDAS1L1

$71.00

TDAS1L2

$134.00

TDAS1R1

$71.00

TDAS1R2

$134.00

TDAS2L1

$71.00

TDAS2L2

$134.00

TDAS1R1

$71.00

TDAS1R2

$134.00

Publication References
Instructions:
Door Hardware
Auxiliary Contact Kit
Flange Stiffener Kit or Extended Length Drive Rod
Extended Drive Stud

GEH-5322
GEH-5323
GEH-5324
GEH-5325

Operating Mechanism:
SDOM1A through SDOM4, SDOM6
TDOM1A through TDOM1D
TDOM3
TDOM4 and TDOM5
TDOM6 and TDOM7

GEH-5684
GEH-5315
GEH-5317
GEH-5318
GEH-5319

MOLDED CASE
CIRCUIT BREAKERS

See Section 21 for publication ordering information.

3

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-95
Prices and data subject to change without notice

Molded Case Circuit Breakers

External Accessories
Door-Mounted Operators

TDM Operating Handle, Fixed or Adjustable Shaft

TDM Handle Operating Mechanisms, Door Mounted
Complete mechanism with handle UL listed, E-57253
Operating mechanism only, UL Component Recognized, E-57253
Breaker
Type

TQD, THQD

TEB, TEC, TB1,
TED, THED

TFC, TFJ,
TFK, THFK

MOLDED CASE
CIRCUIT BREAKERS

TJC, TJD, TJJ,
TJK, THJK,
TB4, TBC4
TKC, TKM,
THKM, TB6,
TBC6, TB8, TBC8
TJ4V, TJL
TK4V, TKL
SE150 (GEH-5611)5
SF250 (GEH-5611)5

3

SG600 (GEH-5653)5

Complete Mechanism1
with NEMA 1, 3R, 12 Handle
Product
List
Number
Price

Box Depth
in Inches
Shallow Mount
3 7/16
Extended Shaft
4 5/16 - 14 5/16
Shallow Mount
4 3/16
Extended Shaft
5-1/8 - 5 7/32
5 1/8 - 5 13/16
5 1/8 - 15
Shallow Mount
5 7/8
Extended Shaft
6 7/8 - 15 1/2
Shallow Mount
5 7/8
Extended Shaft
5 5/8 - 15 5/8
Shallow Mount
7 7/16
Extended Shaft
7 1/32 - 17 5/16
Shallow
Extended
Shallow
Extended
4 3/16
6 1/8 - 15
5 7/8
7 3/4 - 15 1/2
5 7/8
5 5/8 - 15 5/8

TQDHM1

6

SK1200 (GEH-5612)5

7

GO-144A

Operating
Mechanism Only
Product
List
Number
Price

$69.00

TQDOM1

$42.00

TQDHM2

$82.00

TQDOM22

$55.00

TEFHM1

$69.00

TEFOM1

$42.00

TEFHM3

$82.00

TEFOM3

$55.00

TEFHM4
TEFHM2

$82.00
$82.00

TEFOM4
TEFOM2

$55.00
$55.00

TFKHM1

$103.50

TFKOM1

$76.50

TFKHM2

$107.50

TFKOM22

$80.50

TJKHM1

$143.00

TJKOM1

$102.00

TJKHM2

$147.00

TJKOM24

$106.00

TKMHM1

$143.00

TKMOM1

$102.00

TKMHM2

$147.00

TKMOM24

$106.00

TJVHM1
TJVHM2
TKVHM1
TKVHM2
SEFHM1
SEFHM2
SEFHM1
SEFHM2
SGHM1
SGHM2
SKHM1
SKHM2

$143.00
$147.50
$143.00
$147.00
$79.00
$81.50
$79.00
$81.50
$143.00
$147.00
$143.00
$147.00

TJVOM1
TJVOM2
TKVOM1
TKVOM2
SEFOM1
SEFOM22
SEFOM1
SEFOM22
SGOM1
SGOM24
SKOM1
SKOM24

$102.00
$106.00
$102.00
$106.00
$52.00
$55.00
$52.00
$55.00
$102.00
$106.00
$102.00
$106.00

Handle Only
NEMA 1, 3R, 12
Product
List
Number
Price

TH1

TH2

NEMA 4/4X
Product
List
Number
Price

$27.00

THCH453,4

$303.00

–
–
–
–

–
–
–
–

THCH453,4

$303.00

$41.00

TH1

$7.00

TH2

$41.00

1Handle assembly and operating mechanism separately packaged.
2For 15-inch long shaft order Product Number 788A831G10, List Price, $40.00, GO-135B. For 20-inch long shaft order Product Number 788A831G21 List Price $40.00, GO-135B.
3Provides interlocking for J600, SG600 SK1200, and K1200 breakers when used with the extended shaft operating mechanism. For interlocking with E150/SE150, F225 and SF250 order

special shaft Product Number 788A832G1, List Price, $40.00, GO-135B.
4For 15-inch long shaft order Product Number 788A832G2, List Price $40.00, GO-135B. For 20-inch long shaft order Product Number 788A832G5, List Price $40.00, GO-135B.
5Installation instructions publication number.
6MOD 1 is 7 7/16; MOD 2 is 8 3/32.
7MOD 1 is 7 3/16 - 17 3/16; MOD 2 is 7 15/16 - 17 15/16.

Handle Accessories for TDM Operating Mechanisms
Device

Product Number

Replacement neoprene gaskets
for NEMA 1, 3R and 12 enclosures
Use with TH1
Use with TH2

788A742P3
788A742P4

GO-139
List Price

$2.80
$6.10

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-96
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

External Accessories
Door-Mounted Operators

TDR Handle on TEC Mag-Break

TDR Integral Handle Mechanism 1 Suitable for NEMA 12 Applications 2
Breaker Type
TEB, TEC, TB1-B, TED, THED
THLC1
TFC, TFJ, TFK, THFK
THLC2, 4; TLB4
TJD, TJC, TJJ, TJK, THJK, TB4, TBC4
TKC, TKM, THKM, TB6, TB8, TBC6, TBC8
TJ4V, TJL
TKL
SE150, SF250 (GEH-5609)6
SG600 (GEH-5654)6
SK1200 (GEH-5610)6

Vertical Mounting
Product Number

Handle
Horizontal Mounting
Product Number

TEFR1B
TLC1RB
TFKR1B
TLC4RB
TJR1B
TKMR1B
TJVR1B
TJVR1BKLP4
TKVR1B
TKVR1BKLP4
SEFR15
SGR1
SKR1

TEFR1HB
TLC1RHB
TFKR1HB
TLC4RHB
TJR1HB
TKMR1HB
TJVR1HB
TJVR1HBKLP4
TKVR1HB
TKVR1HBKLP4
SEFR1H5
SGR1H
SKR1H

GO-144

List
Price

Ship
Weight

$65.50
$65.50
$78.50
$78.50
$78.50
$128.00
$78.50
$524.00
$128.00
$572.00
$65.50
$78.50
$128.00

Door Ring - Interlock Catch Kit
Product
List
Number
Price

173
173
223
3
5
5

SEFRDRCK
–
343L483G5
343L483G9
343L483G2
SKRDRCK

$11.25
–
$11.25
$11.25
$20.25
$21.75

5

343L483G7

$20.25

5

343L483G8

173
5
5

SEFRDRCK
SGRDRCK
SKRDRCK

NEMA 12 Gasket Kit
Product
List
Number
Price
SEFRGSK

$4.00

–
SGRGSK
SKRGSK

–
$11.00
$11.00

SGRGSK

$11.00

$21.75

SKRGSK

$11.00

$11.25
$20.25
$21.75

SEFRGSK
SGRGSK
SKRGSK

$4.00
$11.00
$11.00

1Not suitable for use with mine duty or heavy duty UVR breakers.
2Requires Gasket kit.
3Shipped 12 per pack.
4With provision for Kirk Key Interlock. Lock supplied by customer (type FN with one-inch bolt projection - bolt extended, key removable with breaker open).
5For F250 Frame also order adapter bracket, Product Number SFRAK, no charge when ordered with handle.

MOLDED CASE
CIRCUIT BREAKERS

6Installation instructions publication number. See Section 21 for publication ordering information.

3

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-97
Prices and data subject to change without notice

Molded Case Circuit Breakers

External Accessories
Motor Operators and Plug-in Hardware
Motor Mounted Mechanism
UL Listed

GO-135S
Voltage
Vac
50/60 Hz
Vdc

Breaker Type

–
1203
2404,5
–
–
120
2404,5
–
–
120
2404,5
–
–
120
2404,5
120
2404
–
–
120
2404
–
–
120
2404
–
–
120
2404
–
–

TEB,1 TEC, TED,1
THED, TB1, THLC12

TFC, TFJ, TFK, THFK

TJC, TJJ, TJD, TJK,
THJK, TB4, TBC4

TKC, TKM, THKM, TB6,
TB8, TBC6, TBC8

SE150

SF250

SG600

SK1200

24
–
–
24
48
125
250
24
48
125
250
24
48
125
250
125
–
24
48
125
–
24
48
125
250
24
48
125
250
24
48

Product
Number

List
Price

TEDMOMA8
TEDMOMA1
TEDMOMA2
TFKMOMA8
TFKMOMA9
TFKMOMA1
TFKMOMA2
TJKMOMA8
TJKMOMA9
TJKMOMA1
TJKMOMA2
TKMMOMA8
TKMMOMA9
TKMMOMA1
TKMMOMA2
SEMOM1
SEMOM2
SEMOM8
SEMOM9
SFMOM1
SFMOM2
SFMOM8
SFMOM9
SGMOM1
SGMOM2
SGMOM8
SGMOM9
SKMOM1
SKMOM2
SKMOM8
SKMOM9

$1572.006
$710.006
$710.006
$1692.006
$1692.006
$1692.006
$1692.006
$2160.006
$2160.006
$2160.006
$2160.006
$2340.006
$2340.006
$2340.006
$2340.006
$710.00
$710.00
$710.00
$710.00
$1692.00
$1692.00
$1692.00
$1692.00
$2160.00
$2160.00
$2160.00
$2160.00
$2340.00
$2340.00
$2340.00
$2340.00

For TJ4V, TJL, TKL, TK4V ONLY 7

MOLDED CASE
CIRCUIT BREAKERS

Breaker Type

3

TJ4V, TJL

TKL, TK4V

Volts
120 Vac
125 Vdc
240 Vac4,5
250 Vdc
24 Vdc
48 Vdc
120 Vac
125 Vdc
240 Vac4,5
250 Vdc
24 Vdc
48 V

343L564G7
343L564G1
343L564G2
SGMSKMOM
343L564G3

–

–

–

Motor Operated Mechanism
on SF-Frame breaker

GEH-5613

GEH-5613

GEH-5657

GEH-5614

GO-135B
Mounting Plate
Product Number

List Price

TJKMOMA1

286A7558G8

$2160.00

TJKMOMA2

286A7558G8

$2160.00

TJKMOMA8
TJKMOMA9

286A7558G8
286A7558G8

$2160.00
$2160.00

TKMMOMA1

286A7558G7

$2340.00

TKMMOMA2

286A7558G7

$2340.00

TKMMOMA8
TKMMOMA9

286A7558G7
286A7558G7

$2340.00
$2340.00

Mounting Screw Kit Product Number

TED, TB1
TFJ, TFK
TJJ, TJK, TB4
SG600
TKM, TB6, TB8, SK
1For use on 3-pole breaker only.

–

Mechanism
Product Number

Mounting Screw Kit for Motor-Operated Mechanism 8
Breaker Type

Installation
Instructions

GO-148B

Mounting Screw Kit for TDR Integral Handle

List Price
Breaker Type

$33.506
$8.706
$87.00
$87.009
$121.00

TFC,TFJ,TFK
TEC,TED,TB1-B, TJC, TJJ,
TJK, TB4, TBC, TKC, TKM,
TB6, TB8, TBC6, TBC8

GO-135B

Mounting Screw Kit
Product Number

List Price

343L564G4

$8.60

No Special Mounting
Screw Required

2Motor-operated mechanisms must have Code Date 506 + or later for use with THLC1.
3TEDMOMA1 not rated at 50 hertz.
4Suitable for use at 208 Vac.
5Not UL listed.

6GO-135B.
7Requires mounting plate which is supplied at no charge when ordered with mechanism.

Order both items.
8Required with plug-in mounting base assembly when used with motor-operating

mechanisms or TDR integral-handle kits. Furnished no charge when ordered with
mounting base.
9GO-135S.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-98
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

External Accessories
Mechanical Interlocks and Locking Devices
Mechanical Interlocks
Walking Beam Type Externally Mounted—UL Component Recognized

E-150, TB1
F225
TJJ, TJK, TJ4V,
THJ4V, TB4
TKM, TK4V, TB6, TB8

Panel
Thickness
in Inches
.25-1.0
.25-1.0
0.38
1.0
.75-1.0

TEDMI
TFKMI
TJKMIB
TJKMIE
TKMMI

List Price
GO-135B
$341.00
$341.00
$341.00
$341.00
$341.001

These face-mounted interlocks prevent two adjacent breakers from
being in the ON position at the same time.

Spectra RMS
Breaker Type
SE150, SF250
SG600
SK1200

Face-mounted
Interlock
Product Number
SEFFMI
SGFMI
SKFMI

List Price
GO-135S

Adapter Kit Required
when using handle
operator (TDM) or
motor operator.
Order separately.

$341.00
$683.00
$683.00

Breaker Type
TQB, TQC, TQL
TQB, TQC, TQL
TQL
TEY
E150 Line
F225 Line,
THLC2, 4
SE150, SF250
SK1200

Device

$33.50
$42.00
$59.50

GO-135B
Product Number
THL103
TQHT1
THT104
TEYLD1
TLD3

$6.504
$2.304
$2.304
$5.00
$5.00

Handle locking

TFKLD1

$6.00

SBD1
SKHDLEXT

Q Line, TEY Mounting Accessories
Description
Back Mounting plates
Screw Type
THQC Breaker held to
Mounting Plate by screw clip
Snap In
THQC, THQC-GF
snaps in to spring retaining clip

Breaker Type

1-pole THQC
2-pole THQC
3-pole THQC
10-pole THQC
1-pole
2-pole
3-pole
10-pole
Bolt-on Base for THQB, TEY
3-pole
1-pole THQC
2-pole THQC
Front-mounting Plates7
3-pole THQC
10-pole THQC
3-pole Plug-in Mounting Base (70 Amp) 3-pole TQL
2-pole Plug-in Mounting Base (70 Amp) 2-pole TQL
3-pole Plug-in Mounting Base (100 Amp) 3-pole TQL
2-pole Plug-in Mounting Base (100 Amp) 2-pole TQL
1 & 2-pole
Pack of 48 Front/Rear Mounting Clips
15-60A THQC
Pack of 24 DIN rail clips
DIN rail THQC

TQPLD1
TQDPLD1
TQDLPDL1
THP100
TEYPLD1
TEFPLD1
TLC1PLD1
TFKPLD1
TLC4PLD1
TJKPLD1
TKMPLD1
SEPLD
SGPLD
SKPLD

Breaker Type

Product Number

TQD
E150
SE150, SF25011
SG600
J600
SK1200
THLC1
THLC2/4

TQDPLD2
TEDPLD2
SEFPLD2
SGPLD2
TJKPLD2
SKPLD2
THLC1PLD2
THLC4PLD2

List Price
$4.70
$20.754
$17.754
$6.504
$9.00
$8.00
$17.00
$4.00
$22.00
$8.00
$28.50
$8.705
$15.005
$28.505

GO-135B
List Price
$32.00
$32.00
$32.005
$48.005
$48.00
$60.005
$48.00
$48.00

List Price

Handle locking
Snap-on handle tie - trip indicating
Snap-on handle tie - solid
Handle locking
Handle locking

Handle locking
Handle extension - replacement

Device Product Number

EUSERC Approved—Factory Installed Only
List Price
GO-135S

SEFFMIAK2
SGFMIAK3
SKFMIAK

Handle-Locking, Handle-Extension Devices

Breaker Type
TQC
TQD
TQDL
TQB, TQL
TEY
E150, TB1
THLC1
F225
THLC2, THLC4, TLB4
J600 Line
K1200 Line
SE150, SF250
SG600
SK1200

GO-135B

PowerMark Gold Main Circuit Breaker Kit
Description
Order appropriate
THQL (10 kAIC) or THHQL
breakers separately.

GO-138M

Product Number

List Price

TQMH000

$10.50

$4.705
$96.505

GO-135B
Product Number
TQCBMPA1
TQCBMPA2
TQCBMPA3
TQCBMPA10
TQCGFBMPA1
TQCGFBMPA2
TQCGFBMPA3
TQCGFBMPA10
TEY3B
TQCFMP1
TQCFMP2
TQCFMP3
TQCFMP10
571B595DDG2
571B595DDG1
565B837G1
565B837G2
THQCFMK

MOLDED CASE
CIRCUIT BREAKERS

Breaker Type

Requires Breaker with
Special Factory Drilling.
Order 2 Breakers per Interlock,
Specifying "Drilled for Mech. Interlock"
Product Number

Standard Padlocking Devices10

List Price
$8.30
$9.80
$12.00
$32.00
$6.106
$7.606
$9.106
$25.006
$31.50
$8.30
$9.80
$12.00
$14.00
$32.008
$23.758
$38.008
$23.758
$48.009

3

THQCDIN
$24.009
1GO-144.
2Not suitable with THCH45 handle.
3Compatible with motor operator only. Product Number SGFMI cannot be used with the

handle operator.
4GO-137A.
5GO-135S.
6GO-133.
7Not UL listed.
8GO-134A.
9Price is per pack.
10Suitable for circuit breakers used in group mounted panelboard construction only except

for J600, K1200, SE150/SF250, SG600 and SK1200 which screw down to face of breaker.
11Field installable.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-99
Prices and data subject to change without notice

Molded Case Circuit Breakers

External Accessories
Breaker Mounting Hardware and Kits

Breaker Mounting Screw Kits
Spectra RMS
Breaker Type

Application
For use on mounting
plates with tapped
holes (4 screws
and lockwashers)

For use on mounting
plates with clearance
holes (4 screws,
lockwashers and nuts)

SE150
SF250
SG600
SK1200
SE150
SF250
SG600
SK1200

GO-135S
Kit
Product Number

Screw Size
(inches)

List Price

SEMSK1
SEMSK3
SFGMSK1
SFMSK1
SFGMSK1
SKMSK1
SEMSK2
SEMSK4
SFGMSK2
SFMSK2
SFGMSK2
SKMSK2

10-33x2 7/8 (std.)
8-32x2 7/8 (opt.)
12-24x3 3/4 (std.)
10-32x3 3/4 (opt.)
12-24x3 3/4
5/16-18x1 1/4
10-32x3 (std.)
8-32x3 (opt.)
12-24x4 (std.)
10-32x4 (opt.)
12-24x4
5/16-18x1 3/4

$2.10
$2.10
$6.10
$6.10
$6.10
$8.70
$2.10
$2.10
$6.10
$6.10
$6.10
$8.70

Back-Connected Line and Load Studs
Breaker Type

Amperes
50

E1504, TB14,
THLC14
TFJ4, TFK4,
THFK4
J600, TJ4V,
TB4, TJL
K1200,
TB6, TB8

150
225
400
600
1200
50

SE150
150

Breaker Mounting Screw Kits

GO-135B

SF250

250

Breaker Type

Product Number

List Price

SG600

600

1-pole E150
2- and 3-pole E150
THLC1
F225
THLC2, 4, TLB4
J600
K1200
1-pole TE, E150
2- and 3-pole E150
THLC1
2- and 3-pole TQD/THQD
F225
THLC2, 4, TLB4
J600
K1200

343L162G1
SEMSK4
343L162G22
SFGMSK2
343L162G24
343L162G20
SKMSK2
343L162G7
SEMSK3
343L162G23
343L184G18
SFGMSK1
343L162G25
343L162G11
SKMSK1

$0.85
$2.101
$2.10
$6.101
$5.70
$4.50
$8.701
$0.85
$2.101
$2.10
$4.402
$6.101
$5.70
$4.50
$8.701

SK1200

1200

THQB

TQBS1
(packaged 24/kit)

$6.003

E150

254V644P1
$0.10
(2 req'd per breaker)

Application

For use on mounting
plates with clearance
holes

MOLDED CASE
CIRCUIT BREAKERS

For use on mounting
plates with tapped holes

24 mounting screws for
connecting low tab to
panel board
Cup washer
(for mounting 1-pole breakers)

Std Pkg

2 25/32 (short)
4 13/32 (long)
3 13/32 (short)
5 25/32 (long)
2 23/32 (short)
5 31/32 (long)
5 17/32
5 17/32
5 1/2
8
2 25/32 (short)
4 13/32 (long)
3 13/32 (short)
5 25/32 (long)
2 23/32 (short)
5 31/32 (long)
2 13/16 (short)
6 1/16 (long)
5 1/2
8

1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
2
2
2
2

Product
Number

List Price

TEF1
TEF2
TEF3
TEF4
TFK1
TFK2
TJK1
TJK2
TKM11
TKM12
TEF1
TEF2
TEF3
TEF4
TFK1
TFK2
SGBCS1
SGBCS2
TKM11
TKM12

$27.00
$27.00
$28.00
$31.50
$38.50
$59.50
$83.50
$119.00
$220.00
$242.00
$27.00
$27.00
$28.00
$31.50
$38.50
$59.50
$119.001
$119.001
$220.00
$242.00

Back-Connected Center Studs
for Dual Voltage Applications
GO-135B
3-pole only. Order frame and trip unit separately. Not UL listed.
Breaker frame can be supplied with center stud connections permitting operation at both voltages with one trip unit rating. At the higher
voltage, connection is made at the line and load terminals only and
thus the trip unit carries all the load current. At the lower voltage,
where current is double, connection is also made through the center
studs permitting half the current to bypass the trip unit. At either
voltage, full-load current is carried by the breaker contacts.
Maximum Frame
Ampere Rating
225A
400A
600A
800A
1200A

3

GO-135B

Length,
Back of Breaker
in Inches

Trip Unit
Maximum
Ampere Rating
110
200
300
400
600

Dual Voltage
Frame Only
Product Number
TFK236F000DV
TJK436F000DV
TJK636F000DV
TKM836F000DV
TKM3FDV

List Price 5
$1244.00
$2364.00
$2576.00
$3095.00
$4064.00

1GO-135S.
2GO148C.
3Price is per screw. Packaged in quantity of 24. Must be ordered in multiples of 24.
4For proper clearance between poles, a short and long stud must be assembled adjacent

to each other.
5Price includes center studs, but does not include line and load back-connected studs or

trip unit.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-100
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

External Accessories
Lugs and Associated Hardware

Breaker with Line and Load Studs

Lugs, Line Shields, Covers and Bus Connectors
Copper-Aluminum Lugs

Copper Only Lugs
With Follower and Extra Plating

GO-135B
Wire Range

For Use With

(1) #14-6 Cu, #12-2 Al
(1) #4-1/0 Cu-Al
(1) #1-300 kcmil Cu-Al
(1) #14-8
(1) #14-3 Cu, #12-1 Al
(1) #6-2/0 Cu, #4-2/0 Al
(1) #3-3/0 Cu, #1-3/0 Al
(1) #4-300kcmil Cu-Al
(1) #4-300kcmil Cu-Al
(1) 6-600kcmil or (2) 2/0-250kcmil Cu-Al
(2) 4/0-350kcmil Cu or (2) 300-500kcmil Al
(1) 750 kcmil Cu-Al
(1) 3/0-500kcmil or (2)3/0-250kcmil Cu-Al
(2) 1/0-250kcmil or (1) #4-600 kcmil Cu-Al
(2) 2/0-500 kcmil Cu-Al
(3) 3/0-500 kcmil Cu-Al
(3) 3/0-500 kcmil Cu-Al
(4) 250-350 kcmil Cu or (4) 250-500 kcmil Al
(3) 750 kcmil Cu-Al
(4) 250-350 kcmil Cu or (4) 250-500 kcmil Al
#14-2/0
(1) 6-600 kcmil or (2) 1/0-250 kcmil Cu
(2) 250-350 kcmil Cu
(1) 1/0-600kcmil or (2) 1/0-250 kcmil Cu
(2) 2/0-500 kcmil Cu
(3) 3/0-500 kcmil Cu
(3) 3/0-500 kcmil Cu
(4) 250-400kcmil Cu
(4) 250-400kcmil Cu

TQC (15-60A) (Non DIN Rail)
TQC (70-100A)
TQD
E150, THLC1, TB1, (15-30A)
E150, THLC1, TB1, (15-60A)
E150, THLC1, TB1, (70-90A)
E150, THLC1, TB1, (100-150A)
F225
THLC2
J400, TB4, J600 (Thru 400A), TJD
J600 (450-600A)
J400, TJD
TLB4, THLC4
K1200, TB6 (300-400A)
K1200, TB6, (500-600A)
K1200 (700-1000A), TB8
TK4V - Load end
K1200 (1200A)

Line Shield

Lug Cover, TKM Breaker
(two per breaker)

Connector (back strap)
Line voltage control wire kit
for terminating control wire at breaker lugs

TK4V - Load end
E150, TB1 (thru 150A)
J400, TB4
J600
K1200, TB6 (300-400A)
K1200, TB6, (500-600A)
K1200 (700-1000A), TB8
TK4V - Load end
K1200 (1200A)
TK4V - Load end
TEB, TEC, TED, THED
TFJ, TFK, TFC
TJJ, TJK, TJC
TC041, TCAL41 Lugs
TC061, TCAL61, TCAL81 Lugs, TC081A
TC0121; TCAL121 Lugs
TH4V, THK9V
TKM
J600
K1200

Product Number

List Price

TQAL3
TQAL4
TCAL25
TCAL14
TCAL12
TCAL12A
TCAL15
TCAL24
TCAL27
TCAL43
TCAL63
TCAL47
TCLK43
TCAL41
TCAL61
TCAL812
TCAL912
TCAL1214
TCAL122
TCAL1314
TC012
TC043
TC063
TC0415
TC061
TC081A
TC091
TC0121
TC0131
TEDLS
TFKLS
TJKLS
789A448G36
789A448G1
789A448G2
286A8066G1
TKMC1
TJLVK7
SKLVK7

$1.50
$1.50
$8.001
$3.00
$3.00
$3.00
$3.00
$8.00
$10.00
$14.00
$23.00
$26.00
$49.00
$38.00
$40.00
$47.003
$47.003
$76.003
$103.005
$76.003
$6.00
$21.00
$34.00
$38.00
$40.00
$53.003
$53.003
$80.003
$80.003
$5.10
$16.25
$14.25
$35.00
$35.00
$35.00
$33.503
$38.00
$9.00
$12.003

1GO-135F.
2Not suitable for 100 A aluminum conductor.
3GO-135S.
4Suitable for 500 kcmil copper for voltage drop considerations.
5Not UL listed.
6End cover supplied with 800A frame is used as lug cover.
73-pole kit.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-101
Prices and data subject to change without notice

MOLDED CASE
CIRCUIT BREAKERS

Accessory

3

Molded Case Circuit Breakers

External Accessories
Lugs and Associated Hardware
Spectra RMS Lugs, Lug Covers, and Bus Lugs
Accessory

GO-135S
Wire Range (Qty.)
Aluminum

15-150
70-250
125-600
125-600
Cu 275-1200
Al 225-1100
300-800
600-1200

$3.00
$8.00
$28.00
$42.00
$103.00
$103.00
$47.00
$76.00

(1) #12-3/0
(1) #8-350 kcmil
(2)2/0-500 kcmil or
(1)#8-600 kcmil

(1) #12-3/0
(1) #8-350 kcmil
(2)2/0-500 kcmil or
(1)#8-600 kcmil

(3)300-750 kcmil

(3)300-750 kcmil

TCAL124

Single lug

(3)3/0-500 kcmil
(4)250-3503 kcmil

(3)3/0-500 kcmil
(4)250-500 kcmil

TCAL81
TCAL1253

SE150

–

–

SE3LCK

SF250

–

–

SF3LCK

SG600

–

–

Single lug
Single lug
Three lug covers for
upper (line) end
Three lug covers for
upper (line) end
3-pole lug cover for
upper (line) or lower (load) end
3-pole lug cover for
upper (line) or lower (load) end7
Lug cover for upper (line)
or lower (load) end4
Single lug
Single lug
2-pole lug kit
3-pole lug kit
Single lug
Single lug
Single lug
Single lug with .25
Quick Connect
for Control Voltage
3-pole kit
3-pole kit
Replacement cover
for MicroVersaTrip Plus
and MicroVersaTrip PM
Cover with access to
instantaneous set point
Cover with no access
to instantaneous set point

SG600

Replacement Lug Covers
and End Covers

TCAL18
TCAL29
TCLK265
TCLK365

SG1LCK
SG1BCK
SK1200

–

–

SK1LCK

SE150
SF250

(1) #12-3/0
(1) #8-350 kcmil
(2)2/0-500 kcmil or
(1)#8-600 kcmil
(3)250-500 kcmil
(4)250-400 kcmil
(3)250-750 kcmil

–
–
–
–
–
–
–

TCO18
TCO19
TCOK265
TCOK365
TCO81A
TCO121
TCO124

SE150
SF250

(1) #12-3/0
(1) #8-350 kcmil

(1) #12-3/0
(1) #8-350 kcmil

TCAL18LV
TCAL29LV

SG600
SK1200

–
–

–
–

SG600

Plated Copper Lugs

SK1200

Line voltage control wire kit
for terminating control wire
at breaker lugs

SGLVK
SKLVK
SPCOV1

SG600 / SK1200

–

–

SPCOV2
SPCOV3

MOLDED CASE
CIRCUIT BREAKERS

List Price

Single lug
Single lug
2-pole lug kit2
3-pole lug kit2

SE150
SF250

SK1200

Clear rating plug cover
with provision for wire seal

Ampacity Range1

Copper

Plated extruded aluminum
lugs for terminating
copper or aluminum cables

Product Number

Description

For Use With

–

$5.10

–

$9.80

–

$21.25

–

$37.00

–

$33.50

15-150
70-250
125-600
125-600
300-800
600-1200
600-1200

$6.00
$21.25
$42.00
$63.00
$53.00
$80.00
$155.00

15-150
70-250

$6.60
$17.75

–
–

$9.00
$12.00

–

$13.25

–

$13.25

–

$13.25

Lugs and Lug Covers for J and K Frames with MVT-4 and RMS-9 Trip Units
Breaker Type

Sensor Rating
(Amps)

TJ, TJL with RMS-9 or MVT-4

3
TKH, TKL with RMS-9

K with MVT-4 TRIP UNIT

150
200
300
400
500
600
400
600
800
1000
1200
400
600
800
1000
1200

Standard Lugs
Cu/Al
List
Product Number
Price

GO-135S

Optional Lugs
Cu Only
List
Product Number
Price

Lug Covers5
Product
List
Number
Price

End Covers5
Product
List
Number
Price

TCAL43

$14.006

TCO43

$21.006

–

–

–

–

TCAL63

$23.006

TCO63

$34.006

–

–

–

–

TCAL81

$47.00

TCO81A

$53.00

286A8066G3

$33.50

286A8066G2

$33.50

286A8066G1

$33.50

286A8066G2

$33.50

286A8066G3

$33.50

286A8066G2

$33.50

286A8066G1

$33.50

286A8066G2

$33.50

TCAL1213

$76.00

TCO121

$80.00

TCAL81-Line3

$47.00

TCO81A-Line

$53.00

TCAL91-Load3

$47.00

TCO91-Load

$53.00

TCAL121-Line3

$76.00
$76.00

TCO121-Line
TCO131-Load

$80.00
$80.00

TCAL131-Load3

1Both copper and aluminum cables may not cover full ampacity range.
2With lug cover for line or load end.
3500 kcmil acceptable for voltage drop considerations.
4100kA, 480 Vac (SKPA) uses longer lug cover/arc shield on upper end. Use Product Number SKPSHLD for replacement. May be used on other SK1200 devices.
5Breakers supplied less lugs with end covers. When ordering K-frame breaker and lugs, order appropriate lug covers.
6GO-135B.
7Required for line end bus connection.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-102
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

External Accessories
Neutral Grounds and Sensors
Power Distribution Lugs

GO-135

Breaker Type

Max Amperes

Wire Range

Product Number

List Price

SE, TED

125

TCAL19PD3

$50.00

SF
SG

250
400

(2) 4-14 or
(1) 2/0-4 Cu only
(6) 4-14 Cu only
(12) 4-14 Cu only

TCAL28PD3
TCAL40PD3

$75.00
$88.00

Neutral Current Sensors
For grounded neutral system ground fault applications
Breaker Type

J

K

GO-135S

Ampere Rating

Product Number

List Price

150
200
300
400
500
600
800
1000
1200

TSRG201
TSRG202
TSRG203
TSRG204
TSRG205
TSRG206
TSKG408
TSKG410
TSKG412

$532.00
$532.00
$532.00
$532.00
$532.00
$532.00
$532.00
$532.00
$532.00

Fungus and Moisture Proofing

GO-135B

Poles

Q Line
E150
F225
J600
K1200
TB-1
TB-4
TB-6, 8
List Price List Price List Price List Price List Price List Price List Price List Price

1, 2
and 3

$8.90
$22.25

$28.50
$62.50

$84.00

Power Distribution Lugs

$84.00

$216.00

$62.50

$231.00 $295.00

Neutral Current Sensor

GO-245B

Description

Product Number

List Price

Portable Test Set

TVRMS2

$3000.00

Rating Plug Removal Tool

MOLDED CASE
CIRCUIT BREAKERS

Test Set for MicroVersaTrip Plus, MicroVersaTrip PM
and MicroVersaTrip RMS-9 Trip Units

GO-135S

Product Number

List Price

TRTOOL

$12.00

"Naval Use" Molded Case Circuit Breakers
The following molded case circuit breaker types are optionally
available as UL listed per Standard 489, Supplement SB for naval use:
—THQB
—THQC
—SE150
—SF250
—SG600
—SK1200

3

Contact GE sales office for price and delivery.
Special Calibration
Contact GE sales office for availability. May void UL listing status.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-103
Prices and data subject to change without notice

Molded Case Circuit Breakers

External Accessories
Plug-in Hardware
Each plug-in mounting base assembly includes all mounting
hardware, studs, and male or female connectors for attachment to
one end of breaker. Studs are of different length so by using proper
combinations of PD1 and PD2 units, adequate electrical spacing will
be assured between adjacent breakers, i.e., a short-long-short (SLS)
unit must be used adjacent to a long-short-long (LSL) unit. Two-pole
breakers of the E150 line require an open-long-short (OLS) unit on
one end of the breaker and a short-long-open (SLO) on the other
since these breakers are built with the normal left pole missing
while the mounting bases are built from standard three-pole
molded supports.

Plug-in Mounting Base with Hardware
Product Number TF23PD2 shown

Spectra RMS and all other two-pole breakers are basically three-pole
devices with the center pole omitted. When these breakers are to be
mounted side by side, a short-open-short (SOS) unit must be used on
one end and a long-open-long (LOL) on the other. Horizontal studs are
normally supplied with the flat surface of studs at right angles to the
long axis of the breaker. If vertical studs are desired, substitute "C" for
"D" in the product number, e.g., TE13PC1 (vertical)
or TE13PD1 (horizontal).
The optional mounting plate (TMP1, etc.) accurately locates and
supports the pair of line and load plug-in mounting-base assemblies
and provides a convenient means to attach the entire unit to a
metal structure, and serves as a dead front barrier. New drawings
are available for customers who prefer to fabricate their own
mounting plates.

Plug-in Mounting Base
Product Number TK123PD2A shown

MOLDED CASE
CIRCUIT BREAKERS

Plug-In Mounting Base Assembly
Ampere
Rating

Breaker
Type

150

E1501
TB1
SE150

225

F225

250

SF250
J400

400

TB4
SG400

3

J600, TJ4V, TJL
600

K1200, TKL, TK4V
TB6
SG600
K1200, TK4V, TKL

800

TB8
SK800

1000

K1200, TK4V, TKL
SK1200

1200

K1200, TK4V, TKL

GO-135B

Plug-In Mounting Bases - 2 Required Per Breaker
Stud Configuration
No. Poles
PD1
PD2
2
3
3
2
3
2
3
2
3
2
3
3
2
3
2
3
2
3
3
2
3
2
3
3
2
3
3
2
3
3

OLS
SLS
SLS
SOS
SLS
SOS
SLS
SOS
SLS
SOS
SLS
SLS2
SOS
SLS
SOS
SLS
SOS
SLS
SLS2
SOS
SLS
SOS
SLS
SLS
SOS
SLS
SLS
SOS
SLS
SLS

SK1200
1Order 3-pole base for use with 2-pole Hi Break and 600 Vac breakers.

Product
Number

SLO
LSL
LSL
LOL
LSL
LOL
LSL
LOL
LSL
LOL
LSL
LSL2
LOL
LSL
LOL
LSL
LOL
LSL
LSL2
LOL
LSL
LOL
LSL
LSL
LOL
LSL
LSL
LOL
LSL
LSL

TE12PD1,2
TE13PD1,2
TE13PD1,2
TF22PD1,2
TF23PD1,2
TF22PD1,2
TF23PD1,2
TJ42PD1A,2A
TJ43PD1A,2A
TJ42PD1A,2A
TJ43PD1A,2A
SGPC1, SGPC2
TJ62PD1A,2A
TJ63PD1A,2A
TK62PD1A,2A
TK63PD1A,2A
TK62PD1A,2A
TK63PD1A,2A
SGPC7
TK82PD1A,2A
TK83PD1A,2A
TK82PD1A,2A
TK83PD1A,2A
TK83PD1A,2A
TK102PD1A,2A
TK103PD1A,2A
TK103PD1A,2A
TK122PD1A,2A
TK123PD1A,2A
TK123PD1A,2A

List Price

Optional Mounting Base
Product Number
List Price

$250.00
$375.00
$375.00
$300.00
$450.00
$300.00
$450.00
$400.00
$600.00
$400.00
$600.00
$600.003
$500.00
$750.00
$500.00
$750.00
$500.00
$750.00
$600.003
$600.00
$900.00
$600.00
$900.00
$900.00
$700.00
$1050.00
$1050.00
$800.00
$1200.00
$1200.00

TMP1
TMP5
TMP1
TMP2
TMP2
TMP2
TMP2
TMP3
TMP3
TMP6
TMP6
SMP3
TMP3
TMP3
TMP4
TMP4
TMP7
TMP7
SMP3
TMP4
TMP4
TMP7
TMP7
TMP4
TMP4
TMP4
TMP4
TMP4
TMP4
TMP4

$40.00
$40.00
$40.00
$40.00
$40.00
$40.00
$40.00
$40.00
$40.00
$50.00
$50.00
$40.003
$40.00
$40.00
$50.00
$50.00
$50.00
$50.00
$40.003
$50.00
$50.00
$50.00
$50.00
$50.00
$50.00
$50.00
$50.00
$50.00
$50.00
$50.00

2Vertical studs only for SG600 frame.
3GO-135S.

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-104
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

External Accessories
R-Frame
Ground Fault Neutral Sensors

GO-245B

Current Sensor Rating

Neutral Sensor Product Number

1000A
1600A
2000A

List Price

TSVG810A
TSVG816A
TSVG820A

$266.00
$266.00
$266.00

1600A Power Break
with TPLUGA16 Adapter and 6 TPLUG108 Lugs

T-Studs
GO-145A
Studs mount to breaker or adapter kit. Studs may be rotated for either vertical or
horizontal bus. Product number includes 1 stud.
Maximum Breaker Ampacity

Product Number

1600A
2000A

List Price

TP16FCA
TP20FCA

$113.00
$113.00

Type TP16FCA T-Stud

Lug Kits
GO-245B
Kits accept Cu/Al wire and are suitable for direct mounting to breaker. Order one kit per line
or load pole. TPLUG108 is suitable for use only with the adapter kits described below.
Maximum
Ampere Rating

Product
Number

Lugs
per Kit

Maximum Cables
per Pole

1000-1600

1600

TPLUG408
TPLUG401

1
1

4
6

Wire Range
Cu/Al

List Price

500-800 kcmil
250-800 kcmil

$39.00
$23.00

Type TPLUG408 Lug Kit

Lug Adapter Kits
GO-245B
Premounts to bus structure allowing cabling or bussing to be
completed prior to breaker mounting. Accepts either lugs or crimp
type connector terminals. Product number includes adapter and
hardware for three-pole line side or three-pole load side connection.
Kits include a set of three corresponding T-studs and are suitable for
use with from 1 to 6 TPLUG108 lugs per pole or with from 1 to 6 Crimp
Lugs (Anderson No. VCEL-075-12H1 or equivalent) per pole.
Maximum Breaker Ampacity

Product Number

List Price

1000/1600 A
2000 A

TPLUGA16
TPLUGA20

$389.00
$486.50

Kirk Key Provision (Factory Installation Only)
GO-145A
Equips the breaker to accept a zero bolt projection Kirk Key device
(supplied by customer) to permit sequencing of breaker operations
with other key-type devices. The key remains captured in the breaker
frame except when the breaker has been locked in the open position.
Not compatible with door interlock and padlock device.
Number of Locks
1
2
3
4

Product Number
TPK01 (Type F)
TPK02 (Type M2F)
TPK03 (Type M3F)
TPK04 (Type M4F)

Terminal Block (Factory Installed Only)
GO-145A
Offers an external means of terminating accessory leads at the
breaker. A maximum of 18 terminals can be supplied on each side
of the breaker (36 terminals total). For stationary breakers only.
Terminal blocks are rated 10 amperes at 600 Vac.
Breaker

Terminals

TRL/TRP
R Frame

6
12
18
24
30
36

Factory Installed Product Numbers
Breaker Envelope Size (Amps)
1000, 1600 and 20001
TPTB1R,L
TPTB2R,L
TPTB3R,L
TPTB4L
TPTB5L
TPTB6L

List Price
$158.00
$221.00
$286.00
$444.00
$508.00
$573.00

1Limited to left side only.

Walking Beam Interlock—Not UL listed

GO-145A

Product Number

List Price

TPWB

$525.00

List Price
$817.00
$817.00
$817.00
$817.00

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-105
Prices and data subject to change without notice

MOLDED CASE
CIRCUIT BREAKERS

Circuit Breaker
Frame Size

3

Molded Case Circuit Breakers

Power Management System Accessories
Spectra RMS Circuit Breakers with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)
Required Accessories
Type

MicroVersaTrip Plus Trip Unit

Accessories

Standard
Ground Fault Option with 3-phase, 4-wire
or 1-phase, 3-wire service
Control Power Option
Standard or with Protective Relaying

MicroVersaTrip PM Trip Unit
Ground Fault Option with 3-phase, 4-wire
or 1-phase, 3-wire service

–
Neutral Current Sensor and Terminal Block
or Neutral Current Sensor and Junction Box
Power Supply Plate or Voltage Module1 or Power Supply Assembly2
Power Supply Plate and Voltage Conditioner Plate or Voltage Module1
or Power Supply Assembly2 and Voltage Conditioner Assembly2
Junction Box, Cable Harness and Auxiliary Switch
Neutral Current Sensor

1For installation into GE Spectra Series Switchboards only.
2Requires fuse protection and other components; refer to accessory detail for additional information.

Power Supply Plate

GO-135PM

The Power Supply Plate is used to provide +24 Vdc control power to Spectra RMS Molded Case Circuit
Breakers with MicroVersaTrip PM or MicroVersaTrip Plus trip systems via the Distribution Cable System.
The Power Supply Plate includes the Power Supply Assembly (product number SPSAA) as an integral component and also includes fuse protection for AC source input. Supplemental +24 Vdc input terminals are
provided for backup control power applications. Five versions are available. Not suitable for 400 Hz.
Description

Voltage Rating

The Power Supply Plate is rated 24 watts
(+24 Vdc at 1.0 amperes) and has the maximum
capacity to power a distribution Cable System
consisting of 20 breakers and has a maximum
system cable length of 40 feet.

120 Vac
208 Vac
240 Vac
480 Vac
600 Vac

Product Number

List Price

SPSA120
SPSA208
SPSA240
SPSA480
SPSA600

$1215.00
$1215.00
$1215.00
$1215.00
$1215.00

Voltage Conditoner Plate

Power Supply Plate

GO-135PM

MOLDED CASE
CIRCUIT BREAKERS

The Voltage Conditioner Plate is used to provide voltage sensing signals to Spectra RMS Molded Case
Circuit Breakers with MicroVersaTrip PM Trip Units via the Distribution Cable System. The Voltage
Conditioner Plate includes the Voltage Conditioner Assembly (product number SVCAA) as an integral
component and also includes fuse protection for the AC source input terminals and three 1-VA high
accuracy potential transformers.
The Voltage Conditioner Plate requires a control power source of +24 Vdc to operate properly (the Power
Supply Assembly or Power Supply Plate can provide this required input). The unit also requires AC direct
voltage inputs from the AC source. A GE POWER LEADER network (commnet) connection is provided.
Seven versions are available. Not suitable for 400 Hz.

3

Voltage Rating and Service Type

Comments

Product Number

List Price

120 Vac Wye system
208 Vac Wye system
240 Vac Delta system
277 Vac Wye system
480 Vac Wye system
480 Vac Delta system
600 Vac Delta system

Phase to Neutral potential
Phase to Phase potential
Phase to Phase potential
Phase to Neutral potential
Phase to Phase potential
Phase to Phase potential
Phase to Phase potential

SVCA120Y
SVCA208Y
SVCA240D
SVCA277Y
SVCA480Y
SVCA480D
SVCA600D

$1000.00
$1000.00
$1000.00
$1000.00
$1000.00
$1000.00
$1000.00

Voltage Conditioner Plate

Note: The Voltage Conditoner Plate has the maximum capacity to power a Distribution Cable System consisting of
20 breakers and has a maximum system cable length of 40 feet.

Distribution Cable Junction Box

GO-135PM

The Distribution Cable Junction Box is a modular connector used to provide quick, easy and reliable
attachment of Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip Plus trip systems or
MicroVersaTrip PM trip systems to the Distribution Cable System. The Junction Box contains two
Distribution Cable Harness plugs, one breaker plug and a terminal block for the connection of a neutral
current sensor and an auxiliary switch. Product number SDCJBA is for general purpose OEM applications. Product number SDCJBB is designed for mounting in Spectra Series Panelboards.
Description

Product Number

List Price

Distribution Cable Junction Box
Distribution Cable Junction Box

SDCJBA
SDCJBB

$155.00
$155.00

Distribution Cable Junction Box

Distribution Cable Harness3
GO-135PM
The Distribution Cable Harness is a modular connector used to carry electronic signals and/or control
power between Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip Plus or MicroVersaTrip
PM Trip Units and Distribution Cable accessories. The harnesses come in three lengths.
Description

Harness Length

Product Number

List Price

Distribution Cable Harness
Distribution Cable Harness
Distribution Cable Harness

11 inches
30 inches
60 inches

SDCHA11
SDCHA30
SDCHA60

$70.00
$80.00
$100.00

3Cannot be connected together. Use 30 inch Distribution Cable Extension (SDCEA30) to extend.

Distribution Cable Harness

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-106
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Power Management System Accessories
Spectra RMS Circuit Breakers with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)
Required Accessories
Type

Accessories

Standard
Ground Fault Option with 3-phase, 4-wire
or 1-phase, 3-wire service
Control Power Option

MicroVersaTrip Plus Trip Unit

–
Neutral Current Sensor and Terminal Block
or Neutral Current Sensor and Junction Box
Power Supply Plate or Voltage Module1 or Power Supply Assembly2
Power Supply Plate and Voltage Conditioner Plate or Voltage Module1
or Power Supply Assembly2 and Voltage Conditioner Assembly2
Junction Box, Cable Harness and Auxiliary Switch
Neutral Current Sensor

Standard or with Protective Relaying
MicroVersaTrip PM Trip Unit
Ground Fault Option with 3-phase, 4-wire
or 1-phase, 3-wire service

1For installation into GE Spectra Series Switchboards only.
2Requires fuse protection and other components; refer to accessory detail for additional information.

Distribution Cable Extension
GO-135PM
The Distribution Cable Extension is used to provide modular expansion of the Distribution
Cable System.
Harness Length

Product Number

List Price

30 inches

SDCEA30

$80.00

Distribution Cable Terminal Block
GO-135PM
The Distribution Cable Terminal Block is a modular attachment primarily used to provide an
alternate means of input to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip
Plus or MicroVersaTrip PM Trip Units. The Terminal Block plugs into the breaker distribution
cable receptacle allowing the direct connection of breaker signals via screw terminals. This
allows point-to-point wiring of breakers instead of using the Distribution Cable System.
Description

Product Number

List Price

Distribution Cable Terminal Block

SDCTBA11

$110.00

Power Supply Assembly
GO-135PM
The Power Supply Assembly is used to provide +24 Vdc Control Power to Spectra RMS
Molded Case Circuit Breakers with MicroVersaTrip Plus or MicroVersaTrip PM trip systems
via the Distribution Cable System. The assembly requires a minimum input voltage of 85 Vac
to operate properly (the maximum voltage rating is 240 Vac). Supplemental +24 Vdc input terminals are provided for backup control power applications. The input must be fused with 1/2
ampere class CC fuses (not included). Not suitable for 400 Hz.
Description

Voltage Rating

The Power Supply Assembly is rated 24 watts
(+24 Vdc @ 1.0 ampere) and has the maximum
capacity to power a Distribution Cable System
consisting of 20 breakers and has a maximum
system cable length of 40 feet.

85 - 240 Vac

Product Number
SPSAA

Description

Voltage Rating
120 Vac

Distribution Cable Terminal Block

List Price
$1000.00

Voltage Conditioner Assembly
GO-135PM
The Voltage Conditioner Assembly is used to provide voltage sensing signals to Spectra RMS
Molded Case Circuit Breakers with MicroVersaTrip PM Trip Units via the Distribution Cable
System. The Voltage Conditioner Assembly requires a control power source of +24 Vdc to
operate properly (the Power Supply Assembly or Power Supply Plate can provide this
required input). The unit also requires 120 Vac voltage inputs from the secondary of three 1VA high accuracy potential transformers (not included). The primary side of the potential
transformers must be fused with three, 1/2 ampere class CC fuses (not included). A GE
POWER LEADER network (commnet) connection is provided. Not suitable for 400 Hz.
Requires 120 Vac voltage inputs from the
secondary of three 1.0 VA high accuracy
potential transformers

Distribution Cable Extension

Product Number
SVCAA

3
Power Supply Assembly

List Price
$680.00

Note: the Voltage Conditioner Assembly has the maximum capacity to power a Distribution Cable System consisting of
20 breakers and has a maximum system cable length of 40 feet.

Voltage Conditioner Assembly

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

MOLDED CASE
CIRCUIT BREAKERS

Description
Distribution Cable Extension

3-107
Prices and data subject to change without notice

Molded Case Circuit Breakers

Power Management System Accessories
Spectra RMS Circuit Breakers with MicroVersaTrip Plus and
MicroVersaTrip PM Trip Units
All Devices UL Listed for Factory or Field Installation (UL File No. E-57253)
Voltage Modules
GO-135PM
The Voltage Module is used primarily as a Spectra Series Switchboard component to provide
+24 Vdc Control Power to Spectra RMS Molded Case Circuit Breakers with MicroVersaTrip
Plus or MicroVersaTrip PM Trip Units via the Distribution Cable System. The Module also provides voltage sensing signals to Spectra RMS Molded Case Circuit Breakers with
MicroVersaTrip PM Trip Units on the same Distribution Cable System. The Module contains
both a Power Supply Plate and a Voltage Conditioner as integral components. It also includes
fuse protection for the AC source input terminals (the modules pressure connectors which
mate with the switchboard interior bus bars). A GE POWER LEADER Network (commnet) connection is provided as well as supplemental 24 Vdc input terminals for backup control power
applications. Seven versions are available. Not suitable for 400 Hz.
Voltage Rating and Service Type

Comments

Product Number

List Price

120 Vac Wye system
208 Vac Wye system
240 Vac Delta system
277 Vac Wye system
480 Vac Wye system
480 Vac Delta system
600 Vac Delta system

Phase to Neutral potential
Phase to Phase potential
Phase to Phase potential
Phase to Neutral potential
Phase to Phase potential
Phase to Phase potential
Phase to Phase potential

ADSVMA120Y
ADSVMA208Y
ADSVMA240D
ADSVMA277Y
ADSVMA480Y
ADSVMA480D
ADSVMA600D

$2350.00
$2350.00
$2350.00
$2350.00
$2350.00
$2350.00
$2350.00

MOLDED CASE
CIRCUIT BREAKERS

Note: The Voltage Module has the maximum capacity to power a Distribution Cable System consisting of 20 breakers
and has a maximum system cable length of 40 feet.

Voltage Module Exterior View

Voltage Module Interior View

3

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-108
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04

Molded Case Circuit Breakers

Accessories–Other
Spectra RMS Circuit Breakers with MicroVersaTrip Plus and MicroVersaTrip PM Trip Units
All Devices UL Listed for Factory or Field Installation Except Where Noted

Neutral Current Sensor
GO-135S
The neutral current sensor is used in conjunction with breakers that have a MicroVersaTrip
Plus or MicroVersaTrip PM Trip Unit with the optional ground fault function and the breaker is
connected to a grounded neutral service (3-phase, 4-wire or 1-phase, 3-wire). The neutral
current sensor provides an input signal to the breaker trip unit. Breakers connected to a
service without a neutral (3-phase, 3-wire) require no external connection or shorting of the
breaker cable connector for ground fault to function properly.
Breaker Type

Sensor Rating (S)

Product Number

List Price

SG
SG
SG
SK
SK

150
400
600
800
1200

TSRG201
TSRG204
TSRG206
TSKG408
TSKG412

$532.00
$532.00
$532.00
$532.00
$532.00

MicroVersaTrip Rating Plug Removal Tool

GO-135S

Product Number

List Price

TRTOOL

$12.00

Description

Product Number

List Price

Portable Power Pack

TVPBP

$75.00

MOLDED CASE
CIRCUIT BREAKERS

MicroVersaTrip Portable Power Pack
GO-245A
The hand-held MicroVersaTrip portable battery pack provides an independent power source
for MicroVersaTrip Plus and MicroVersaTrip PM trip units as an alternative to the TVRMS test
set. The power pack is used to power up the trip unit to set or adjust trip set points when the
breaker is on the bench or otherwise not powered up. It connects to the trip unit through the
rating plug test jack. It requires three standard 9 Vdc alkaline batteries (not included).

MicroVersaTrip Portable Test Set
GO-245A
The portable, battery-powered test kit provides for RMS-9, Plus, or PM trip unit self-tests and
functional trip/no trip tests. It also provides defeat of the ground fault function and can be
used in conjunction with high current test equipment. Interface is via a plug on the front of
the trip unit and tests can be conducted with breaker in service. Kit uses six rechargeable
ni-cad or standard alkaline "D" cells supplied by customer. Kit can also be powered by 120
Vac source.
Description

Product Number

List Price

Portable Test Set2

TVRMS2

$3000.00

3

2May also be used to temporarily defeat ground fault function when using primary injection (high current test set).

Note: This test kit is for use with MicroVersaTrip RMS-9, Plus, or PM Trip Units only. Not for use with MicroVersaTrip
4- or 9-Function Trip Units.

Publications and Reference: See Section 21
for a list of additional product-related publications
distributed by AA Electric 1-800-237-8274 www.a-aelectric.com
Rev. 12/04

www.geelectrical.com

BuyLog Catalog

3-109
Prices and data subject to change without notice

Molded Case Circuit Breakers

MOLDED CASE
CIRCUIT BREAKERS

NOTES:

3

distributed by AA Electric 1-800-237-8274 www.a-aelectric.com

3-110
Prices and data subject to change without notice

BuyLog Catalog

www.geelectrical.com

Rev. 12/04



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 5.0.5 for Macintosh
Keywords                        : 
Create Date                     : 2004:12:22 09:16:38-05:00
Modify Date                     : 2005:12:27 16:09:06-05:00
Metadata Date                   : 2005:12:27 16:09:06-05:00
Creator Tool                    : QuarkXPressª: PSPrinter 8.3.1
Web Statement                   : http://www.geindustrial.com/cwc/aboutus/terms_of_use.htm
Marked                          : True
Format                          : application/pdf
Title                           : GE 2005 Buylog - Section 3: Molded Case Circuit Breakers
Description                     : Electrical Distribution - Low and Medium Voltage Components and Equipment
Rights                          : © 2005 General Electric Company
Creator                         : GE Consumer & Industrial: Commercial & Industrial Marketing
Document ID                     : uuid:3c86a6ad-6fb4-11d9-bb70-000d936ed7ce
Instance ID                     : uuid:90d8a465-beb0-4660-99c2-56a0ca455b04
Has XFA                         : No
Page Count                      : 110
Subject                         : Electrical Distribution - Low and Medium Voltage Components and Equipment
Author                          : GE Consumer & Industrial: Commercial & Industrial Marketing
EXIF Metadata provided by EXIF.tools

Navigation menu