Cooper B Line Meter Mounting Equipment 200 Amp Self Contained
2014-07-29
: Pdf 123351-Attachment 123351-Attachment 782051 Batch6 unilog
Open the PDF directly: View PDF .
Page Count: 4
Data subject to change without notice. Consult local utility for area acceptance. All dimensions in inches.
1
Single Meter Sockets/
Without Bypass
4
Single Meter Sockets Without Bypass
200 Amp Self-Contained
APPLICATION
• Type 3R construction
•Some styles available in stainless steel (SS)
•Snap type sealing ring included
•5th jaw provision at nine o’clock
•Ring style
CONSTRUCTION
•UL 414 listed, complies with ANSI C12.7
STANDARDS
•ANSI 61 gray acrylic electrocoat finish
FINISH
•5th jaw kit — catalog #50365
•Screw type sealing ring — catalog #25016D (included with MS73 catalog numbers)
•Steel and clear lexan covers for socket opening
• AW hubs
ACCESSORIES
• Single meter position
•Designed to receive watthour meters that meet ANSI C12.10
•Surface or semi-flush mounting
•Overhead or underground feed
204
*2" hub included **Includes 2" hub and screw type sealing ring
Overhead–Surface Mount
CONDUCTOR LUG RANGE DIMENSIONS (INCHES)
CATALOG AIC AMPACITY VOLTAGE SERVICE NUMBER HUB PHASE CONDUCTOR NEUTRAL FIGURE HEIGHT WIDTH DEPTH
NUMBER RATING MAX. CONT.TYPE OF JAWS PROV.LINE/LOAD CONDUCTOR NUMBER (H) (W) (D)
204 ✝200 -- 600 1Ø 3W 4 AW 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 7 15 8 1⁄44 5⁄8
204MS68* ✝200 -- 600 1Ø 3W 4 AW 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 7 15 8 1⁄44 5⁄8
204MS68A** ✝200 -- 600 1Ø 3W 4 AW 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 7 15 8 1⁄44 5⁄8
Underground–Surface Mount
CONDUCTOR LUG RANGE DIMENSIONS (INCHES)
CATALOG AIC AMPACITY VOLTAGE SERVICE NUMBER HUB PHASE CONDUCTOR NEUTRAL FIGURE HEIGHT WIDTH DEPTH
NUMBER RATING MAX. CONT.TYPE OF JAWS PROV.LINE/LOAD CONDUCTOR NUMBER (H) (W) (D)
U204 ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 2 15 12 4 5⁄8
U204MS73 ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 2 15 12 4 5⁄8
U204MSCD ✝250 200 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 2 15 12 4 5⁄8
U204MS73CD ✝250 200 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 2 15 12 4 5⁄8
Overhead/Underground–Surface Mount
CONDUCTOR LUG RANGE DIMENSIONS (INCHES)
CATALOG AIC AMPACITY VOLTAGE SERVICE NUMBER HUB PHASE CONDUCTOR NEUTRAL FIGURE HEIGHT WIDTH DEPTH
NUMBER RATING MAX. CONT.TYPE OF JAWS PROV.LINE/LOAD CONDUCTOR NUMBER (H) (W) (D)
U204MS21 ✝200 -- 600 1Ø 3W 4 AW 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 4 15 12 4 5⁄8
U204SSMS21 ✝200 -- 600 1Ø 3W 4 AW 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 4 15 12 4 5⁄8
U207 ✝250 200 600 3Ø 4W 7 AW 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 6 18 12 5
U207MS73 ✝250 200 600 3Ø 4W 7 AW 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 6 18 12 5
Overhead–Flush Mount
CONDUCTOR LUG RANGE DIMENSIONS (INCHES)
CATALOG AIC AMPACITY VOLTAGE SERVICE NUMBER HUB PHASE CONDUCTOR NEUTRAL FIGURE HEIGHT WIDTH DEPTH
NUMBER RATING MAX. CONT.TYPE OF JAWS PROV.LINE/LOAD CONDUCTOR NUMBER (H) (W) (D)
204F ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 1,8 15 8 6
204FMS73 ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 1,8 15 8 6
MS21 = 2” AW Hub installed
Data subject to change without notice. Consult local utility for area acceptance. All dimensions in inches.
1
Single Meter Sockets/
Without Bypass
5
Single Meter Sockets Without Bypass
200 Amp Self-Contained
Knockouts — Conduit Sizes
Fig. 1 Fig. 2
2 1⁄8
Fig. 3
Fig. 4
Fig. 8
Fig. 5
Fig. 6
Fig. 7
AA = 1⁄4"
AB = 1⁄2"
AC = 1⁄2" – 1⁄4"
AZ = 2" – 1 1⁄2" – 1 1⁄4" – 1"
BE = 2 1⁄2" – 2" – 1 1⁄2" – 1 1⁄4"
HA = AW HUB
WD
H
WD
H
WD
H
W
D
H
WD
H
WD
H
WD
H
4
4
4
AZ
AZ
AZ
HA
BE
HA
AZ AZ
AB
AA
AZ
AZ AZ
BE BE AZ
AA
AZ
AZ AZ
BE
BE BE
BE
BE BE
BE
BE BE
AC
AC
BE
BE BE
BE BE AZ
HA
AB
AZ
AZ AZ
AZ
AA
AZ
AZ
AZ
AZ
AZ
BE BE AZ
3 7⁄83 7⁄8
2 1⁄8
3 7⁄83 7⁄8
3 7⁄83 7⁄8
2 1⁄8
3 7⁄83 7⁄8
2 1⁄8
3 7⁄83 7⁄8
2 1⁄8
✝
= Meter sockets shown on pages 4 & 5 have certain short circuit current ratings when used in conformance with the tables on page 8.
MS73 = Includes screw type sealing ring
Underground-Flush Mount
CONDUCTOR LUG RANGE DIMENSIONS (INCHES)
CATALOG AIC AMPACITY VOLTAGE SERVICE NUMBER HUB PHASE CONDUCTOR NEUTRAL FIGURE HEIGHT WIDTH DEPTH
NUMBER RATING MAX. CONT.TYPE OF JAWS PROV.LINE/LOAD CONDUCTOR NUMBER (H) (W) (D)
U204F ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 3,8 15 12 6
U204FMS73 ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 3,8 15 12 6
U204FSS ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 3,8 15 12 6
U204FMSCD ✝250 200 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 3,8 15 12 6
U204FMS73CD ✝250 200 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 3,8 15 12 6
U207F ✝250 200 600 3Ø 4W 7 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 5 18 12 5
Data subject to change without notice. Consult local utility for area acceptance. All dimensions in inches.
1
Single Meter Sockets/
Without Bypass
6
Single Meter Sockets Without Bypass
200 Amp Self-Contained
Underground-Surface Mount
CONDUCTOR LUG RANGE DIMENSIONS (INCHES)
CATALOG AIC AMPACITY VOLTAGE SERVICE NUMBER HUB PHASE CONDUCTOR NEUTRAL FIGURE HEIGHT WIDTH DEPTH
NUMBER RATING MAX. CONT.TYPE OF JAWS PROV.LINE/LOAD CONDUCTOR NUMBER (H) (W) (D)
UG204 ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 1 17 14 4 5⁄8
UG204MS82 ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 350 kcmil/6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 1 17 14 4 5⁄8
UG204MSCD ✝250 200 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 1 17 14 4 5⁄8
UG204MS82CD ✝250 200 600 1Ø 3W 4 NONE 6 AWG - 350 kcmil/6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 1 17 14 4 5⁄8
UG204SS ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 1 17 14 4 5⁄8
Underground-Flush Mount
CONDUCTOR LUG RANGE DIMENSIONS (INCHES)
CATALOG AIC AMPACITY VOLTAGE SERVICE NUMBER HUB PHASE CONDUCTOR NEUTRAL FIGURE HEIGHT WIDTH DEPTH
NUMBER RATING MAX. CONT.TYPE OF JAWS PROV.LINE/LOAD CONDUCTOR NUMBER (H) (W) (D)
UG204F ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 2,3 17 14 6
UG204FMS82 ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 350 kcmil/6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 2,3 17 14 6
UG204FMSCD ✝250 200 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 2,3 17 14 6
UG204FMS82CD ✝250 200 600 1Ø 3W 4 NONE 6 AWG - 350 kcmil/6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 2,3 17 14 6
UG204FSS ✝200 -- 600 1Ø 3W 4 NONE 6 AWG - 250 kcmil 6 AWG - 250 kcmil Fig. 2,3 17 14 6
APPLICATION
• Type 3R construction
• Dedicated straight wire line section
•Some styles available in stainless steel (SS)
•Snap type sealing ring included
•5th jaw provision at nine o’clock
•Ring style
CONSTRUCTION
•UL 414 listed, complies with ANSI C12.7
STANDARDS
•ANSI 61 gray acrylic electrocoat finish
FINISH
•5th jaw kit — catalog #50365
•Screw type sealing ring — catalog #25016D
•Steel and clear lexan covers for socket opening
ACCESSORIES
• Single meter position
• Designed to receive watthour meters that meet ANSI C12.10
•Surface or flush mounting
•Underground feed
UG204
✝=
Meter sockets shown on this page have certain short circuit current ratings when used in conformance with the tables on page 8.
Data subject to change without notice. Consult local utility for area acceptance. All dimensions in inches.
1
Single Meter Sockets/
Without Bypass
7
Single Meter Sockets Without Bypass
200 Amp Self-Contained
Knockouts — Conduit Sizes
Fig. 1 Fig. 2
AZ
AZ
AA
BE
BK
AZ AZ AZ
BE
BEBE
AZ AZ
AZ
AA
Fig. 3
AA = 1⁄4"
AZ = 2" – 1 1⁄2" – 1 1⁄4" – 1"
BE = 2 1⁄2" – 2" – 1 1⁄2" – 1 1⁄4"
BK = 3" – 2 1⁄2" – 2" – 1 1⁄2"
4 1⁄8
WD
H
WD
H
5 5
2 5⁄16
4 23⁄32 4 23⁄32
2 9⁄32