• Revised • 02/26/12 EQ Load Centers—Small Circuit Load Centers ® LOAD CENTERS & CIRCUIT BREAKERS 1 1-Phase, 3-WIre SN, 120/240Volts AC Features/Applications EQ Load Centers with main lugs feature a combination trim box in one package. b Interiors offer removal in seconds b Single phase b One piece bus bar construction designed for use only with circuit breakers b UL Listed b UL listed on 60/75°C conductors (see equipment markings for applications) b Positive load side circuit breaker hook rails b Outdoor Type 3R devices use HS Type hubs. See page 1-21. Small Circuit Load Centers Renovation Panel Ideal for older home renovation projects where the distance between the studs is narrower than current construction practices. The narrower panel eliminates the need to ‘notch’ out the existing studs. Ideal for subfeed applications Main Lugs with Aluminum Bus 4–16 circuits, 100–125 Amperes Branch Circuits Amp Rating 100 125 125 125 125 Max. 1-Pole No. of Spaces No. of Circuits 12 4 4 4 8 24 8 8 8 16 QP Max. 2-Poles Indoor Enclosure — NEMA Type 1 Outdoor Enclosure — NEMA Type 3R Catalog Number— Replace Suffix F (Flush) with S for Surface Mounting Std. Pkg. 1 5 — — 1 Dimensions (inches) H W D Catalog Number 14 3/4 12 5/8 — — 14 3/4 12 3/8 6 5/8 — — 12 3/8 3 7/8 3 1/2 — — 3 7/8 — W0408ML1125 bd W0408L1125SPA50 cdh W0408L1125SPA60 cdh — Main Lug and Main Breaker with Copper Bus 4–16 circuits, 100–225 Amperes Branch Circuits Amp Rating 100 100 125 125 225 200 150 200 Max. 1-Pole No. of Spaces 10 12 8 8 4 4 4 4 20 24 16 16 6 4 4 4 QP Max. 2-Poles 4 6 4 4 2 2 2 2 Catalog Number Std. Pkg. E1020MB1100FCGP g E1224ML1100FCU E0816ML1125FCUe E0816ML1125SCU — — — — 1 1 1 1 1 1 1 1 0 amp maximum breaker. 7 Will not accommodate 2-pole GFCI or circuit breaker with shunt trip. c Can accommodate 2-pole GFCI breaker up to 50A. For 2-pole 60A GFCI, a restriction of #6 wire applies due to wire bend space of the enclosure. Will not accommodate circuit breaker with shunt trip. d 100 amp maximum breaker. a b 1-18 Std Pkg. — 5 1 1 — Dimensions (inches) H W D — 12 1/4 12 1/4 12 1/4 — — 6 6 6 — — 4 1/4 4 1/4 4 1/4 — 100,000A IR 1-Phase, 3-Wire, SN 120/240 Volts AC Indoor Enclosure — NEMA Type 1 No. of Circuits Spa Panels are ideal for outdoor applications requiring the use of ground fault protection, such as hot tubs. A factory installed 2-Pole GFCI breaker is provided, along with 2 extra circuits. 100,000A IR 1-Phase, 3-Wire, SN 120/240 Volts AC E1224ML1100FGa E0408ML1125F bde — — E0816ML1125F e 6 2 2 2 4 Spa Panels Outdoor Enclosure — NEMA Type 3R Dimensions (inches) H 14 14 14 14 — — — — W 3/4 3/4 3/4 3/4 12 12 12 12 — — — — 3/8 3/8 3/8 3/8 D Catalog Number Std. Pkg. 3 7/8 3 7/8 3 7/8 3 7/8 — — — — — — W0816ML1125CUe — W0406ML1225CUb W0404MB1200CTjk W0404MB1150CTSk W0404MB1200CTSk — — 1 — 1 1 1 1 uitable for use as service entrance equipment when a main S breaker (125A maximum) is back-fed in a branch position and used with main breaker retainer clip (Cat. No. ECMBR1). f Suitable for use as service entrance when not more than six main disconnecting means are provided. Check local codes and restrictions. g Two Q115 and one Q230 breaker included. h W0408L1125SPA50 provided with factory installed QF50 and ground bar. W0408L1125SPA60 provided with factory installed QF260 and ground bar. e Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Dimensions (inches) H W D — — 14 3/4 — 23 20 20 20 — — 12 — 10 11 11 11 — — 4 1/4 — 4 1/8 4 3/4 4 3/4 4 3/4 1/8 1/8 1/8 1/8 opper Bus load centers are recommended for those C applications where the environment may be severe (i.e. farm and coastal areas). j 2" HS Type hub provided. k Type QNR main breaker factory installed. CSA Listed Cover plate included i Product Category RESI • Revised • 01/22/13 EQ Load Centers—Circuit Breaker Enclosures ® 1-Phase and 3-Phase, 240V AC Max. 1 Features LOAD CENTERS & CIRCUIT BREAKERS b Circuit breaker enclosures range from 60A to 225A, indoor and outdoor models b Designed for use exclusively with QP, QT, QPH, HQP, BQ, BQH, HBQ, QPP, QPPH, HQPP, QJ2, QJH2 and QJ2-H circuit breakers b UL listed b Suitable for use as service entrance equipment b UL listed for 60/75°C conductors (See equipment markings for applications) b Outdoor type 3R devices use HS type hubs (pg. 1-21) except for the W0204ML1060 which uses the HA type hub W0202MB1200CU Breaker Used Frame Type E0303ML3100CU Indoor Enclosure — NEMA Type 1 Ampere Rating No. of Poles Catalog Number Std. Pkg. Outdoor Enclosure — NEMA Type 3R Dimensions (inches) Height Depth Catalog Number Std. Pkg. 1/8 1/8 3/8 1/8 — — 8 1/2 2 5/8 2 5/8 4 5/16 4 1/4 — — 4 W0204ML1060 a — W0202MB1100CU d W0204ML1125CU W0202MB1150CUd W0202ML1200CU W0202MB1200CU d 5 — 1 1 1 1 1 Width Dimensions (inches) Height Width Depth 1-Phase, 3-Wire SN — 120/240 Volts AC 60 60 100 125 150 200 200 2 2 2 2 2 2 2 E0204ML1060S a E0204ML1060F E0202MB1100d E0204ML1125SCU — — E0202MB12004 5 5 1 1 — — — QPP, QPPH, HQPP, QP 225 1-4 — — — — — W0406ML1225CU b QJ2, QJH2, QJ2-H 150 200 225 2 2 2 — — — — — — — — — — — — — — — WB2150B e WB2200B e WB2225 b QP, QPH, HQP QN, QNH, HQN 9 9 17 17 7/8 7/8 1/8 1/8 — — 19 3/8 5 5 7 7 18 — 17.4 17 1/8 19 3/4 19 3/4 19 3/4 15 — 7.3 17 3/8 18.4 18.4 18.4 4 1/4 — 4.3 4 5/16 4.6 4.6 4.6 1 23 10 4 1/8 1 1 1 27 27 27 17 3/8 17 3/8 17 3/8 4 15/16 4 15/16 4 5/16 3-Phase, 3-Wire 240 Volts AC or 3-Phase, 4-Wire SN — 120/208 Volts AC, 120/240, 240 Volts AC QP, QPH,HQP 100 2-3 E0303ML3100S c 1 17 1/8 7 1/8 4 1/4 W0303ML3100 c 1 17 1/8 17 3/8 4 5/16 BQ, BQH, HBQ 100 2-3 EB3100S c 1 17 1/8 7 1/8 4 1/4 WB3100 c 1 17 1/8 17 3/8 4 5/16 2-3 EB3225F b 5 1/8 WB3225 b 1 27 10 1/8 5 9/16 QJ2, QJH2, QJ2-H a b 225 ill not accommodate 2-pole GFCI or circuit breaker with W shunt trip. 42,000A IR maximum. Copper wire only at 225A. Product Category RESI 1 c 27111 10 1/8 an accommodate 2-pole GFCI breaker up to 50A. For C 2-pole GFCI, a restriction of #6 wire applies due to wire bend space of the enclosure. Will not accommodate circuit breaker with shunt trip. d e ain breaker factory installed. M QJ2 frame circuit breaker installed, rated 10,000A IR. CSA Listed. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 1-19 • Revised • 01/22/13 Load Centers LOAD CENTERS & CIRCUIT BREAKERS 1 Load Center OEM Interiors 1Ø: Small Circuit Main Lug Interiors Dimensions Amps 60 60 125 125 125 200 200 Catalog Numberb Spaces 2 3 4 8 8 4 12 I0204ML1125 I0303ML3100 I0408ML1125 I0816ML1125CU I0816ML1125CUSP I0202L1200 I1220L1200CT Circuits 2 3 8 16 16 4 20 Height 5.06 5.06 4.51 6.19 6.19 3.88 9.00 W Width 2.12 3.12 6.61 6.81 6.81 7.13 7.00 W H H I1220L1200CT 1Ø: High Circuit Main Lug Interiors with Neutral Bars d Dimensions Amps 125 125 125 200 200 200 200 200 200 225 Catalog Numberb I1224L1125CU I1624L1125CU I3040L1125CU I0816L1200CTd I1224L1200CU I1632L1200CU I2040L1200CU I3040L1200CU I4040L1200CU I4242L1225CU Spaces 12 16 30 8 12 16 20 30 40 42 Circuits 24 24 40 16 24 32 40 40 40 42 Spaces 12 12 24 30 42 12 12 18 18 24 30 42 Circuits 24 24 42 54 42 24 24 36 36 42 54 42 Height 10.80 12.80 20.80 10.80 10.80 12.80 14.80 14.80 24.80 26.80 I0204ML1125 Width 9.80 9.80 9.80 9.80 9.80 9.80 9.80 9.80 9.80 9.80 W W H H Parallel Lug I0816ML1125CU 3Ø: Main Lug Interiors Dimensions Amps 125 200 200 200 225 125 200 200 125 200 200 225 Catalog Number SI1224L3125B SI1224L3200B SI2442L3200B SI3054L3200B SI4242L3225B PI1224L3125CUB PI1224L3200CUB PI1836L3200CUB PI1836L3125CUB PI2442L3200CUB PI3054L3200CUB PI4242L3225CUB Height 10.04 10.04 16.04 19.04 25.04 10.04 10.04 13.04 13.04 10.04 19.04 25.04 Width 9.95 9.95 9.95 9.95 9.95 9.95 9.95 9.95 9.95 9.95 9.95 9.95 W W H H I0408ML1125 1 Phase 1Ø: Parallel Lug Interiors with Neutral Bars W Dimensions Amps Catalog Numberb 200 200 200 CTI2040L1200CU CTI2440L1200CU CTI3040L1200CU Spaces 20 24 30 Circuits 40 40 40 Height 14.80 16.80 20.80 Width 9.80 9.80 9.80 W H H Lug Data Interior I0204ML1060 I0303ML3100 I1224ML1100 I0408ML1125 I0816ML1125CU/CUSP Single Phase Single Phase Three Phase Three Phase a b Amperage 60 100 100 125 60 125 200/225 125 200/225 Wire range 2/0 - 4 AWG 2/0 - 4 AWG 2/0 - 4 AWG 2/0 - 4 AWG 2/0 - 4 AWG 2/0 - 4 AWG 300 kcmil - 4 AWG 300 kcmil - 6 AWG 300 kcmil - 6 AWG L Recognized Components. U The letters “CU” in any catalog number represent copper bus bars. 1-20 c d Torque 45 lb. - ins. 45 lb. - ins. 45 lb. - ins. 45 lb. - ins. 45 lb. - ins. 110 lb. - ins. 250 lb. - ins. 340 lb. - ins. 340 lb. - ins. I0202L1200 3 Phase eed thru lugs provided. F Convertible to main breaker using the MBK main breaker kits. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Product Category RESI • Revised • 01/22/13 Load Centers Load Center Accessories Pack Qty Description EC1GB8 EC1GB82 EC2GB12 EC2GB122 EC2GB15 EC2GB152 EC3GB21 EC3GB212 EC3GB27 EC3GB272 EC3GB30 EC3GB302 EC3GB352 EC3GB352G GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND GROUND BAR BAR BAR BAR BAR BAR BAR BAR BAR BAR BAR BAR BAR BAR KIT-8 POS KIT-8 POS, 2/0 LUG KIT-12 POS KIT-12 POS, 2/0 LUG KIT-15 POS KIT-15 POS, 2/0 LUG KIT-21 POS KIT-21 POS, 2/0 LUG KIT-27 POS KIT-27 POS, 2/0 LUG KIT-30 POS KIT-30 POS, 2/0 LUG KIT-35 POS, 2/0 LUG KIT-35 POS, 2/0 LUG 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Ground Bar Kits (For Legacy Load Centers) ECGB5 ECGB10 ECGB101 ECGB14 ECGB141 ECGB142 ECGB20 ECGB201 ECGB202 ECINSGB5 ECINSGB14 ECINSGB20 GROUND BAR KIT-5 POS GROUND BAR KIT-10 POS GROUND BAR KIT-10 POS, 1/0 LUG GROUND BAR KIT-14 POS GROUND BAR KIT-14 POS, 1/0 LUG GROUND BAR KIT-14 POS, 2/0 LUG GROUND BAR KIT-20 POS GROUND BAR KIT-20 POS, 1/0 LUG GROUND BAR KIT-20 POS, 2/0 LUG INSULATED GROUND BAR KIT-5 POS INSULATED GROUND BAR KIT-14 POS INSULATED GROUND BAR KIT-20 POS 1 1 1 1 1 1 1 1 1 1 1 1 HS TYPE CLOSURE PLATE HS TYPE HUB - 3/4" HS TYPE HUB - 1" HS TYPE HUB - 1 1/4" HS TYPE HUB - 1 1/2" HS TYPE HUB - 2" HS TYPE HUB - 2 1/2" HA TYPE CLOSURE PLATE HA TYPE HUB - 3/4' HA TYPE HUB - 1" HA TYPE HUB - 1 1/4" HA TYPE HUB - 1 1/2" HV TYPE CLOSURE PLATE HV TYPE HUB - 2" HV TYPE HUB - 2.5" HV TYPE HUB 3" HV TYPE HUB - 3.5" HV TYPE HUB - 4" 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Hubs ECHS000 ECHS075 ECHS100 ECHS125 ECHS150 ECHS200 ECHS250 ECHA000 ECHA075 ECHA100 ECHA125 ECHA150 ECHV000 ECHV200 ECHV250 ECHV300 ECHV350 ECHV400 Lock Kits ECQFL2 ECQFL1 ECQFL3 FLUSH LOCK KIT FOR ULT., PL, ES, 3PH 100A-225A FLUSH LOCK KIT-REPLACEMENT FOR EQ LC ADD-A-LOCK (FLUSH LOCK ) FOR 300-400A LC 1 1 1 Description Pack Qty Load Center Conversion Kits MBK100A MBK125A MBK150A MBK200A MBK225A MBK3100 MBK3125 MBK3150 MBK3175 MBK3200 MBK3225 MBK3125H MBK3150H MBK3175H MBK3200H MBK3225H MBK3125HH MBK3150HH MBK3175HH MBK3200HH MBK3225HH ECMLK125 ECMLK225 ECMLK3125 ECMLK3225 MAIN BREAKER KIT 100-125A 1PH 22K MAIN BREAKER KIT 125A 1PH 22K MAIN BREAKER KIT 150A-225A 1PH 22K MAIN BREAKER KIT 200A-225A 1PH 22K MAIN BREAKER KIT 225A 1PH 22K MAIN BREAKER KIT 100A 3PH QP 240V 10K MAIN BREAKER KIT 125A 3PH QP 240V 10K MAIN BREAKER KIT 150A 3PH 240V 10K MAIN BREAKER KIT 175A 3PH 240V 10K MAIN BREAKER KIT 200A 3PH 240V 10K MAIN BREAKER KIT 225A 3PH 240V 10K MAIN BREAKER KIT 125A 3PH 240V 22K MAIN BREAKER KIT 150A 3PH 240V 22K MAIN BREAKER KIT 175A 3PH 240V 22K MAIN BREAKER KIT 200A 3PH 240V 22K MAIN BREAKER KIT 225A 3PH 240V 22K MAIN BREAKER KIT 125A 3PH 240V 42K MAIN BREAKER KIT 150A 3PH 240V 42K MAIN BREAKER KIT 175A 3PH 240V 42K MAIN BREAKER KIT 200A 3PH 240V 42K MAIN BREAKER KIT 225A 3PH 240V 42K 1 PH MAIN LUG CONVERSION KIT 100-125A 1 PH MAIN LUG CONVERSION KIT 150-225A 3 PH MAIN LUG CONVERSION KIT 100-125A 3 PH MAIN LUG CONVERSION KIT 150-225A 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 COLLAR STRAP FOR GRD BARS #14-1/0 COLLAR STRAP FOR GRD BARS #6-250 NEUTRAL LUG KIT WITH BOND TAB NEUTRAL LUG KIT #1-300 FOR EQIII LC NEURTAL LUG KIT #2 TO 1/0 FOR EQIII LC NEUTRAL LUG KIT #4-2/0 FOR EQIII LC, PL, ES 2/0 LUG FOR 125AMP NEUTRAL FEEDER 125A SUB FEED LUGS-USES 2 SPACES 150A-225A SUB FEED LUGS-USES 4 SPACES 3P SUB FEED LUGS-USES 6 SPACES RISER LUG KIT 250 KCMIL 1 1 1 1 1 1 1 1 1 1 3 Lug Kits ECCS1 ECCS2 ECLKB1 ECLK3 ECLK1-2 ECLK2 ECLK2SC ECLK2125 ECLK2225 ECLK3225 ECRLK250 Miscellaneous Load Center Accessories ECCP1 ECQF3 ECMBF125 EC3PMFP1 ECSMK1 ECTS2 ECTS2W ECLCHINGE ECADHLCDIRLBL ECSIELATCH ECBONDSCRW ECSN1 PKG OF 100 CIRCUIT DIRECTORY QP/BQ/ED2 FILLER PLATE 1 PH 100&125A MAIN BREAKER FILLER PLATE 3 POLE MAIN FILLER PLATE SURFACE MOUNT 1/4" SPACE KIT FOR LC'S LC TRIM SCREWS LC TRIM SCREWS WHITE GREY LC HINGES ADHESIVE LC DIRECTORY LABELS SIEMENS LC LATCHES LC BOND SCREW SCREWS & NUTS FOR HC HUB-BOTTOM USE RAG24 RISER AUX GUTTER 24" ECAFL ARC FLASH LABEL 100 5 1 1 4 6 6 100 100 25 10 4 1 10 Neutral Bar Kits ECLNB14 MLO NEUTRAL BAR KIT-14 POS 1 ECLNB16 CONVERTIBLE LC NEUTRAL BAR KIT-16 POS 1 The pack quantity is the number that is sold in a pack. Items listed on this page must be ordered in multipiles of pack quantities but items are priced per each. For example, ECRLK250 come 3 to a pack so must be ordered in multiples of 3 but pricing would be individual unit price times 3. Bar has green-colored screws. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 1-21 LOAD CENTERS & CIRCUIT BREAKERS Ground Bar Kits (For ES and PL Load Centers) Catalog Number 1 Catalog Number • Revised • 02/26/12 Load Centers LOAD CENTERS & CIRCUIT BREAKERS 1 Load Center Accessories Lug Kit, 3-Pole, Subfeed or Feed thru Applications ECLK3225 Neutral Bar Kit ECLNB14 3-Pole Main Breaker Kit MBK3200 Main Breaker Retainer Kit for EQ Load Centers ECMBR1 Ground Bar Kit, EC2GB15 Add-A-Lock (Flush Lock) ECQFL1 For EQ load centers 1-22 Main Breaker Retainer kit for Ultimate, ES, & PL Load Centers ECMBR2 Neutral Lug Kit, ECLK1-2 wire range — #2-1 AWG Cu or Al Filler Plate, ECQF3 Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Riser Lug Kit ECRLK250 Neutral Lug Kit, ECLK3 wire range — #1-300 MCM Neutral Lug Kit, ECLK2 wire range — #4-#2/0 AWG Cu or Al For use on Ground Bar only Collar Strap, Wire Range; ECCS1; ECCS2 Add-A-Lock (Flush Lock), ECQFL2 for Ultimate, ES & PL Load Centers and 3-phase up to 225A Add-A-Lock (Flush Lock), ECQFL3 300-400A Load Centers • Revised • 01/22/13 Load Centers Manual Transfer Interlock Kits for Load Centers and Meter Combinations n UL listed for use in most Siemens load centers and meter combinations Standby power main breaker Utility main breaker MM0406L1* MC1212L1200* n Suitable for use with optional standby systems in accordance with article 702 of the National Electric Code n Corrosion resistant finish n Easy assembly requiring no modifications to the load center or meter combination Wire forms or bussing To activate standby power the utility main breaker must be in the “OFF” position to prevent dangerous feedback between the power sources. n Remains attached to the main breakers when load center cover Acceptable usage of Interlock Kits by load center/meter combination catalog numbers ES Series Load Centers can utilize interlock kits: 1, 2, 5, 6, 7. Kits 3 and 4 can also be used on main breaker panels. PL Series Load Centers can utilize interlock kits: 1, 2, 3, 4, 5, 6, 7. Numbers 1 through 9 in these tables represent the last digit in each interlock kit catalog number. Example: 1 = ECSBPK01 Siemens Meter Combinations MC0816B1150RTH 5 7 MC2040S1200JLC 9 MC0816B1150T 5 7 MC2442B1225EFC 2 MC0816B1150TH 5 7 MC2442B1225ESC 2 MC0816B1200EFN 2 MC3040S1200SC 5 MC0816B1200RT 5 7 MC3042B1200FED 3 MC0816B1200RTB 5 7 MC3042B1200SED 3 MC0816B1200RTH 5 7 MC3042B1225FED 3 MC0816B1200ESN 2 MC3042B1225SED 3 MC0816B1200T 7 MC4040B1200SECW 5 7 MC0816B1200TH 5 7 MC4040S1200SC 5 7 MC0816B1350RLTM 5 7 MC0816B1200RJBT 8 MC0816B1400RLTM 5 7 MC0816B1150RJBT 8 MC1224B1100EFC 2 MC0816B1200RCT 8 MC1224B1100ESC 2 MC0816B1150RCT 8 MC1224B1125 1 MC0816B1200CT 8 2 MC1224B1125EFC 2 MC0816B1150CT 8 When used in horizontal positions as typical in most load centers, ECSBPK07 is recommended for use only with QNR type circuit breakers. MC1224B1125ESC 2 MC2040B1150RCT 9 MC2040B1150 5 7 MC2040B1150CT 9 Standby power interlock kits are not intended for use with AFCI, GFCI, 3-pole or 1/2” frame circuit breakers and 4 space, 125 amp load centers. MC2040B1200 5 7 MC2040B1200RCT 9 MC2040B1200R 5 7 MC2040B1200CT 9 Siemens type EQ load centers using a “4-pole” main breaker do not have a kit available to interlock this main to branch circuits. Branch circuit positions can be interlocked. 7 No interlock kit available for MC0816S1200SCT, MC2442S1200SC, MC2442S1200FC, MC2040S1200SZ, MM02025S1200H, MM0202S1200RHJ, MM0202S1200RJB Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 1-23 LOAD CENTERS & CIRCUIT BREAKERS Standard features Panels in which the bussing or wire forms from the meter socket land on main lugs are not acceptable for use in standby systems because turning the main breaker to “OFF” does not prevent feedback to the utility power lines. Examples of such panels include catalog numbers that start with the following letters. MC0606L1200* 1 Convert load centers or meter combinations into standby power panels Load Centers Prevents dangerous feedback between two sources of power LOAD CENTERS & CIRCUIT BREAKERS 1 Manual Transfer Interlock Kits for Load Centers and Meter Combinations Catalog number Usage Information Utility main breaker types Standby main breaker types Interlock number ECSBPK01 For use on load centers or meter combinations that will accept 2pole circuit breakers opposite one another as shown. QP, QPH, HQPH QP, QPH, HQPH 1 ECSBPK02 For use on load centers or meter combinations that will accept 2or 4-pole next to a 2-pole circuit breaker side by side as shown. QP, QPH, HQPH QP, QPH, HQPH 2 ECSBPK03 For use on UltimateTM and Rock Solid load centers, 150 amp and higher, to connect the main breaker to a 2-pole circuit breaker. MBK150A, MBK200A, OR MBK225A QP, QPH, HQPH 3 ECSBPK04 For use on Ultimate and Rock Solid load centers, 125 amp and lower, to connect the main breaker to a 2-pole circuit breaker. MBK100A or MBK125A QP, QPH, HQPH 4 ECSBPK05 For use on load centers or meter meter combinations that will accept a QNR (MD-TR) frame circuit breaker next to a 2-pole circuit breaker as shown. QNR, QNRH, HQNR QP, QPH, HQPH 5 ECSBPK06 For use on load centers or meter combinations that will accept a QN (MD-T) frame circuit breaker next to a 2-pole circuit breaker as shown. QN, QNH, HQN QP, QPH, HQPH 6 ECSBPK07 For use on load centers or meter combinations that will accept two QNR (MD--TR) circuit breakers side by side as shown OR will accept two QN (MD--T) circuit breakers side by side as shown. QNR, QNRH, HQNR, QN, QNH, HQN QNR, QNRH, HQNR QN, QNH, HQN 7 ECSBPK08 For use on 8 space, over/under, OH/UG feed meter combinations as shown. Limited application to specific catalog numbers. QPP, QPPH QP, QPH, HQPH 8 ECSBPK09 For use on 20 space, over/under, OH/UG feed meter combinations as shown. Limited application to specific catalog numbers. QPP, QPPH QP, QPH, HQPH 9 Manual breaker interlock kits are attached to the breakers not the trim of the load center. 1-24 These kits take up 2 spaces adjacent to the 2 pole breaker being interlocked. Those spaces cannot accommodate filler plates. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Source Exif Data:
File Type : AI File Type Extension : ai MIME Type : application/vnd.adobe.illustrator PDF Version : 1.6 Linearized : No Create Date : 2014:03:30 19:05:05-04:00 Creator : Adobe InDesign CS4 (6.0.6) Modify Date : 2014:03:30 19:12:07-04:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-21:37:19 Metadata Date : 2014:03:30 19:12:07-04:00 Creator Tool : Adobe InDesign CS4 (6.0.6) Format : application/pdf Document ID : uuid:5179926c-80f7-5643-88fe-90d7a5e6b7c9 Instance ID : uuid:07a640f7-9abd-b743-a5a2-df55a293d0e1 Producer : Adobe PDF Library 9.0 Page Count : 7 For : Susan Spencer, Title : Untitled Extract Pages.pdf Bounding Box : 0 0 603 783 Container Version : 11 Creator Version : 14 Image Height : 783 Image Width : 603 Image Size : 603x783 Megapixels : 0.472EXIF Metadata provided by EXIF.tools