EQ Load Centers—Small Circuit Load Centers
®

LOAD CENTERS &
CIRCUIT BREAKERS

1

1-Phase, 3-WIre SN, 120/240Volts AC
Features/Applications
EQ Load Centers with main lugs
feature a combination trim box in one
package.
b Interiors offer removal in seconds
b Single phase
b One piece bus bar construction
designed for use only with circuit
breakers
b UL Listed
b UL listed on 60/75°C conductors
(see equipment markings for applications)
b Positive load side circuit breaker hook
rails
b Outdoor Type 3R devices use HS
Type hubs. See page 1-21.

Small Circuit Load
Centers

Renovation Panel
Ideal for older home renovation projects where the distance between the studs is
narrower than current
construction practices. The
narrower panel eliminates
the need to ‘notch’ out the
existing studs.

Ideal for subfeed
applications

Main Lugs with Aluminum Bus 	
4–16 circuits, 100–125 Amperes	
Branch Circuits

Amp
Rating
100
125
125
125
125

Max.
1-Pole
No. of
Spaces

No. of
Circuits

12
4
4
4
8

24
8
8
8
16

QP
Max.
2-Poles

Indoor Enclosure — NEMA Type 1

Outdoor Enclosure — NEMA Type 3R

Catalog Number—
Replace Suffix F
(Flush) with S for
Surface Mounting

Std.
Pkg.
1
5
—
—
1

Dimensions (inches)
H

W

D

Catalog
Number

14 3/4
12 5/8
—
—
14 3/4

12 3/8
6 5/8
—
—
12 3/8

3 7/8
3 1/2
—
—
3 7/8

—
W0408ML1125 bd
W0408L1125SPA50 cdh
W0408L1125SPA60 cdh
—

Main Lug and Main Breaker with Copper Bus	
4–16 circuits, 100–225 Amperes	
Branch Circuits

Amp
Rating
100
100
125
125
225
200
150
200

Max.
1-Pole
No. of
Spaces
10
12
8
8
4
4
4
4

20
24
16
16
6
4
4
4

QP
Max.
2-Poles
4
6
4
4
2
2
2
2

Catalog
Number

Std.
Pkg.

E1020MB1100FCGP g
E1224ML1100FCU
E0816ML1125FCUe
E0816ML1125SCU
—
—
—
—

1
1
1
1
1
1
1
1

 0 amp maximum breaker.
7
Will not accommodate 2-pole GFCI or circuit breaker with
shunt trip.
c Can accommodate 2-pole GFCI breaker up to 50A. For
2-pole 60A GFCI, a restriction of #6 wire applies due to
wire bend space of the enclosure. Will not accommodate
circuit breaker with shunt trip.
d 100 amp maximum breaker.
a
b

1-18

Std
Pkg.
—
5
1
1
—

Dimensions (inches)
H

W

D

—
12 1/4
12 1/4
12 1/4
—

—
6
6
6
—

—
4 1/4
4 1/4
4 1/4
—

100,000A IR
1-Phase, 3-Wire, SN 120/240 Volts AC

Indoor Enclosure — NEMA Type 1

No. of
Circuits

Spa Panels are ideal for outdoor applications requiring
the use of ground fault protection, such as hot tubs. A
factory installed 2-Pole GFCI
breaker is provided, along
with 2 extra circuits.

100,000A IR
1-Phase, 3-Wire, SN 120/240 Volts AC

E1224ML1100FGa
E0408ML1125F bde
—
—
E0816ML1125F e

6
2
2
2
4

Spa Panels

Outdoor Enclosure — NEMA Type 3R

Dimensions (inches)
H
14
14
14
14
—
—
—
—

W
3/4
3/4
3/4
3/4

12
12
12
12
—
—
—
—

3/8
3/8
3/8
3/8

D

Catalog
Number

Std.
Pkg.

3 7/8
3 7/8
3 7/8
3 7/8
—
—
—
—

—
—
W0816ML1125CUe
—
W0406ML1225CUb
W0404MB1200CTjk
W0404MB1150CTSk
W0404MB1200CTSk

—
—
1
—
1
1
1
1

 uitable for use as service entrance equipment when a main
S
breaker (125A maximum) is back-fed in a branch position and
used with main breaker retainer clip (Cat. No. ECMBR1).
f Suitable for use as service entrance when not more than six
main disconnecting means are provided. Check local codes and
restrictions.
g Two Q115 and one Q230 breaker included.
h W0408L1125SPA50 provided with factory installed QF50 and
ground bar. W0408L1125SPA60 provided with factory installed
QF260 and ground bar.
e

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

Dimensions (inches)
H

W

D

—
—
14 3/4
—
23
20
20
20

—
—
12
—
10
11
11
11

—
—
4 1/4
—
4 1/8
4 3/4
4 3/4
4 3/4

1/8

1/8
1/8
1/8

 opper Bus load centers are recommended for those
C
applications where the environment may be severe
(i.e. farm and coastal areas).
j 2" HS Type hub provided.
k Type QNR main breaker factory installed.
 CSA Listed
 Cover plate included
i

Product Category RESI

• Revised •
01/22/13

EQ Load Centers—Circuit Breaker Enclosures
®

1-Phase and 3-Phase, 240V AC Max.

1

Features

LOAD CENTERS &
CIRCUIT BREAKERS

b 	 Circuit breaker enclosures range from 60A to
225A, indoor and outdoor models
b 	 Designed for use exclusively with QP, QT,
QPH, HQP, BQ, BQH, HBQ, QPP, QPPH,
HQPP, QJ2, QJH2 and QJ2-H circuit breakers
b 	 UL listed
b 	 Suitable for use as service entrance
equipment
b 	 UL listed for 60/75°C conductors
(See equipment markings for applications)
b 	 Outdoor type 3R devices use HS type hubs
(pg. 1-21) except for the W0204ML1060
which uses the HA type hub

W0202MB1200CU

Breaker Used
Frame
Type

E0303ML3100CU

Indoor Enclosure — NEMA Type 1
Ampere
Rating

No. of
Poles

Catalog
Number

Std.
Pkg.

Outdoor Enclosure — NEMA Type 3R

Dimensions (inches)
Height

Depth

Catalog
Number

Std.
Pkg.

1/8
1/8
3/8
1/8
—
—
8 1/2

2 5/8
2 5/8
4 5/16
4 1/4
—
—
4

W0204ML1060 a
—
W0202MB1100CU d
W0204ML1125CU
W0202MB1150CUd
W0202ML1200CU
W0202MB1200CU d

5
—
1
1
1
1
1

Width

Dimensions (inches)
Height

Width

Depth

1-Phase, 3-Wire SN — 120/240 Volts AC
60
60
100
125
150
200
200

2
2
2
2
2
2
2

E0204ML1060S a
E0204ML1060F
E0202MB1100d
E0204ML1125SCU
—
—
E0202MB12004

5
5
1
1
—
—
—

QPP, QPPH,
HQPP, QP

225

1-4

—

—

—

—

—

W0406ML1225CU b

QJ2,
QJH2,
QJ2-H

150
200
225

2
2
2

—
—
—

—
—
—

—
—
—

—
—
—

—
—
—

WB2150B e
WB2200B e
WB2225 b

QP, QPH,
HQP

QN, QNH,
HQN

9
9
17
17

7/8
7/8
1/8
1/8
—
—
19 3/8

5
5
7
7

18
—
17.4
17 1/8
19 3/4
19 3/4
19 3/4

15
—
7.3
17 3/8
18.4
18.4
18.4

4 1/4
—
4.3
4 5/16
4.6
4.6
4.6

1

23

10

4 1/8

1
1
1

27
27
27

17 3/8
17 3/8
17 3/8

4 15/16
4 15/16
4 5/16

3-Phase, 3-Wire 240 Volts AC or 3-Phase, 4-Wire SN — 120/208 Volts AC, 120/240, 240 Volts AC
QP, QPH,HQP

100

2-3

E0303ML3100S c

1

17 1/8

7 1/8

4 1/4

W0303ML3100 c

1

17 1/8

17 3/8

4 5/16

BQ, BQH, HBQ

100

2-3

EB3100S c

1

17 1/8

7 1/8

4 1/4

WB3100 c

1

17 1/8

17 3/8

4 5/16

2-3

EB3225F b

5 1/8

WB3225 b

1

27

10 1/8

5 9/16

QJ2, QJH2,
QJ2-H

a
b

225

 ill not accommodate 2-pole GFCI or circuit breaker with
W
shunt trip.
42,000A IR maximum. Copper wire only at 225A.

Product Category RESI

1

c

27111

10 1/8

 an accommodate 2-pole GFCI breaker up to 50A. For
C
2-pole GFCI, a restriction of #6 wire applies due to wire
bend space of the enclosure. Will not accommodate circuit breaker with shunt trip.

d
e


 ain breaker factory installed.
M
QJ2 frame circuit breaker installed, rated 10,000A IR.
CSA Listed.

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

1-19

• Revised •
01/22/13

Load Centers

LOAD CENTERS &
CIRCUIT BREAKERS

1

Load Center OEM Interiors
1Ø: Small Circuit Main Lug Interiors
Dimensions
Amps
60
60
125
125
125
200
200

Catalog Numberb

Spaces
2
3
4
8
8
4
12

I0204ML1125
I0303ML3100
I0408ML1125
I0816ML1125CU
I0816ML1125CUSP
I0202L1200
I1220L1200CT

Circuits
2
3
8
16
16
4
20

Height
5.06
5.06
4.51
6.19
6.19
3.88
9.00

W

Width
2.12
3.12
6.61
6.81
6.81
7.13
7.00

W

H
H

I1220L1200CT

1Ø: High Circuit Main Lug Interiors with Neutral Bars

d

Dimensions
Amps
125
125
125
200
200
200
200
200
200
225

Catalog Numberb
I1224L1125CU
I1624L1125CU
I3040L1125CU
I0816L1200CTd
I1224L1200CU
I1632L1200CU
I2040L1200CU
I3040L1200CU
I4040L1200CU
I4242L1225CU

Spaces
12
16
30
8
12
16
20
30
40
42

Circuits
24
24
40
16
24
32
40
40
40
42

Spaces
12
12
24
30
42
12
12
18
18
24
30
42

Circuits
24
24
42
54
42
24
24
36
36
42
54
42

Height
10.80
12.80
20.80
10.80
10.80
12.80
14.80
14.80
24.80
26.80

I0204ML1125
Width
9.80
9.80
9.80
9.80
9.80
9.80
9.80
9.80
9.80
9.80

W

W

H

H

Parallel Lug

I0816ML1125CU

3Ø: Main Lug Interiors



Dimensions
Amps
125
200
200
200
225
125
200
200
125
200
200
225

Catalog Number
SI1224L3125B
SI1224L3200B
SI2442L3200B
SI3054L3200B
SI4242L3225B
PI1224L3125CUB
PI1224L3200CUB
PI1836L3200CUB
PI1836L3125CUB
PI2442L3200CUB
PI3054L3200CUB
PI4242L3225CUB

Height
10.04
10.04
16.04
19.04
25.04
10.04
10.04
13.04
13.04
10.04
19.04
25.04

Width
9.95
9.95
9.95
9.95
9.95
9.95
9.95
9.95
9.95
9.95
9.95
9.95

W
W

H

H

I0408ML1125
1 Phase

1Ø: Parallel Lug Interiors with Neutral Bars

W

Dimensions
Amps

Catalog Numberb

200
200
200

CTI2040L1200CU
CTI2440L1200CU
CTI3040L1200CU

Spaces
20
24
30

Circuits
40
40
40

Height
14.80
16.80
20.80

Width
9.80
9.80
9.80

W

H

H

Lug Data
Interior
I0204ML1060
I0303ML3100
I1224ML1100
I0408ML1125
I0816ML1125CU/CUSP
Single Phase
Single Phase
Three Phase
Three Phase

a
b

Amperage
60
100
100
125
60
125
200/225
125
200/225

Wire range
2/0 - 4 AWG
2/0 - 4 AWG
2/0 - 4 AWG
2/0 - 4 AWG
2/0 - 4 AWG
2/0 - 4 AWG
300 kcmil - 4 AWG
300 kcmil - 6 AWG
300 kcmil - 6 AWG

 L Recognized Components.
U
The letters “CU” in any catalog number represent copper
bus bars.

1-20

c
d

Torque
45 lb. - ins.
45 lb. - ins.
45 lb. - ins.
45 lb. - ins.
45 lb. - ins.
110 lb. - ins.
250 lb. - ins.
340 lb. - ins.
340 lb. - ins.

I0202L1200

3 Phase

 eed thru lugs provided.
F
Convertible to main breaker using the MBK main breaker
kits.

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

Product Category RESI

• Revised •
01/22/13

Load Centers
Load Center Accessories
Pack
Qty

Description

EC1GB8
EC1GB82
EC2GB12
EC2GB122
EC2GB15
EC2GB152
EC3GB21
EC3GB212
EC3GB27
EC3GB272
EC3GB30
EC3GB302
EC3GB352
EC3GB352G

GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND
GROUND

BAR
BAR
BAR
BAR
BAR
BAR
BAR
BAR
BAR
BAR
BAR
BAR
BAR
BAR

KIT-8 POS
KIT-8 POS, 2/0 LUG
KIT-12 POS
KIT-12 POS, 2/0 LUG
KIT-15 POS
KIT-15 POS, 2/0 LUG
KIT-21 POS
KIT-21 POS, 2/0 LUG
KIT-27 POS
KIT-27 POS, 2/0 LUG
KIT-30 POS
KIT-30 POS, 2/0 LUG
KIT-35 POS, 2/0 LUG
KIT-35 POS, 2/0 LUG

1
1
1
1
1
1
1
1
1
1
1
1
1
1

Ground Bar Kits (For Legacy Load Centers)
ECGB5
ECGB10
ECGB101
ECGB14
ECGB141
ECGB142
ECGB20
ECGB201
ECGB202
ECINSGB5
ECINSGB14
ECINSGB20

GROUND BAR KIT-5 POS
GROUND BAR KIT-10 POS
GROUND BAR KIT-10 POS, 1/0 LUG
GROUND BAR KIT-14 POS
GROUND BAR KIT-14 POS, 1/0 LUG
GROUND BAR KIT-14 POS, 2/0 LUG
GROUND BAR KIT-20 POS
GROUND BAR KIT-20 POS, 1/0 LUG
GROUND BAR KIT-20 POS, 2/0 LUG
INSULATED GROUND BAR KIT-5 POS
INSULATED GROUND BAR KIT-14 POS
INSULATED GROUND BAR KIT-20 POS

1
1
1
1
1
1
1
1
1
1
1
1

HS TYPE CLOSURE PLATE
HS TYPE HUB - 3/4"
HS TYPE HUB - 1"
HS TYPE HUB - 1 1/4"
HS TYPE HUB - 1 1/2"
HS TYPE HUB - 2"
HS TYPE HUB - 2 1/2"
HA TYPE CLOSURE PLATE
HA TYPE HUB - 3/4'
HA TYPE HUB - 1"
HA TYPE HUB - 1 1/4"
HA TYPE HUB - 1 1/2"
HV TYPE CLOSURE PLATE
HV TYPE HUB - 2"
HV TYPE HUB - 2.5"
HV TYPE HUB 3"
HV TYPE HUB - 3.5"
HV TYPE HUB - 4"

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Hubs
ECHS000
ECHS075
ECHS100
ECHS125
ECHS150
ECHS200
ECHS250
ECHA000
ECHA075
ECHA100
ECHA125
ECHA150
ECHV000
ECHV200
ECHV250
ECHV300
ECHV350
ECHV400

Lock Kits
ECQFL2
ECQFL1
ECQFL3

FLUSH LOCK KIT FOR ULT., PL, ES, 3PH
100A-225A
FLUSH LOCK KIT-REPLACEMENT FOR
EQ LC
ADD-A-LOCK (FLUSH LOCK )
FOR 300-400A LC

1
1
1

Description

Pack
Qty

Load Center Conversion Kits
MBK100A
MBK125A
MBK150A
MBK200A
MBK225A
MBK3100
MBK3125
MBK3150
MBK3175
MBK3200
MBK3225
MBK3125H
MBK3150H
MBK3175H
MBK3200H
MBK3225H
MBK3125HH
MBK3150HH
MBK3175HH
MBK3200HH
MBK3225HH
ECMLK125
ECMLK225
ECMLK3125
ECMLK3225

MAIN BREAKER KIT 100-125A 1PH 22K
MAIN BREAKER KIT 125A 1PH 22K
MAIN BREAKER KIT 150A-225A 1PH 22K
MAIN BREAKER KIT 200A-225A 1PH 22K
MAIN BREAKER KIT 225A 1PH 22K
MAIN BREAKER KIT 100A 3PH QP 240V 10K
MAIN BREAKER KIT 125A 3PH QP 240V 10K
MAIN BREAKER KIT 150A 3PH 240V 10K
MAIN BREAKER KIT 175A 3PH 240V 10K
MAIN BREAKER KIT 200A 3PH 240V 10K
MAIN BREAKER KIT 225A 3PH 240V 10K
MAIN BREAKER KIT 125A 3PH 240V 22K
MAIN BREAKER KIT 150A 3PH 240V 22K
MAIN BREAKER KIT 175A 3PH 240V 22K
MAIN BREAKER KIT 200A 3PH 240V 22K
MAIN BREAKER KIT 225A 3PH 240V 22K
MAIN BREAKER KIT 125A 3PH 240V 42K
MAIN BREAKER KIT 150A 3PH 240V 42K
MAIN BREAKER KIT 175A 3PH 240V 42K
MAIN BREAKER KIT 200A 3PH 240V 42K
MAIN BREAKER KIT 225A 3PH 240V 42K
1 PH MAIN LUG CONVERSION KIT 100-125A
1 PH MAIN LUG CONVERSION KIT 150-225A
3 PH MAIN LUG CONVERSION KIT 100-125A
3 PH MAIN LUG CONVERSION KIT 150-225A

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

COLLAR STRAP FOR GRD BARS #14-1/0
COLLAR STRAP FOR GRD BARS #6-250
NEUTRAL LUG KIT WITH BOND TAB
NEUTRAL LUG KIT #1-300 FOR EQIII LC
NEURTAL LUG KIT #2 TO 1/0 FOR EQIII LC
NEUTRAL LUG KIT #4-2/0 FOR EQIII LC, PL, ES
2/0 LUG FOR 125AMP NEUTRAL FEEDER
125A SUB FEED LUGS-USES 2 SPACES
150A-225A SUB FEED LUGS-USES 4 SPACES
3P SUB FEED LUGS-USES 6 SPACES
RISER LUG KIT 250 KCMIL

1
1
1
1
1
1
1
1
1
1
3

Lug Kits
ECCS1
ECCS2
ECLKB1
ECLK3
ECLK1-2
ECLK2
ECLK2SC
ECLK2125
ECLK2225
ECLK3225
ECRLK250

Miscellaneous Load Center Accessories
ECCP1
ECQF3
ECMBF125
EC3PMFP1
ECSMK1
ECTS2
ECTS2W
ECLCHINGE
ECADHLCDIRLBL
ECSIELATCH
ECBONDSCRW
ECSN1

PKG OF 100 CIRCUIT DIRECTORY
QP/BQ/ED2 FILLER PLATE
1 PH 100&125A MAIN BREAKER FILLER PLATE
3 POLE MAIN FILLER PLATE
SURFACE MOUNT 1/4" SPACE KIT FOR LC'S
LC TRIM SCREWS
LC TRIM SCREWS WHITE
GREY LC HINGES
ADHESIVE LC DIRECTORY LABELS
SIEMENS LC LATCHES
LC BOND SCREW
SCREWS & NUTS FOR HC HUB-BOTTOM USE

RAG24

RISER AUX GUTTER 24"

ECAFL

ARC FLASH LABEL

100
5
1
1
4
6
6
100
100
25
10
4
1
10

Neutral Bar Kits
ECLNB14

MLO NEUTRAL BAR KIT-14 POS

1

ECLNB16

CONVERTIBLE LC NEUTRAL BAR KIT-16 POS

1

	 The

pack quantity is the number that is sold in a pack. Items listed on this page must be ordered
in multipiles of pack quantities but items are priced per each. For example, ECRLK250 come 3 to a
pack so must be ordered in multiples of 3 but pricing would be individual unit price times 3.
	Bar has green-colored screws.

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

1-21

LOAD CENTERS &
CIRCUIT BREAKERS

Ground Bar Kits (For ES and PL Load Centers)

Catalog Number

1

Catalog
Number

• Revised •
02/26/12

Load Centers

LOAD CENTERS &
CIRCUIT BREAKERS

1

Load Center Accessories

Lug Kit, 3-Pole, Subfeed or
Feed thru Applications
ECLK3225

Neutral Bar Kit
ECLNB14

3-Pole Main Breaker Kit
MBK3200

Main Breaker Retainer Kit for EQ
Load Centers
ECMBR1

Ground Bar Kit, EC2GB15

Add-A-Lock
(Flush Lock) ECQFL1
For EQ load centers

1-22

Main Breaker Retainer kit for
Ultimate, ES, & PL Load Centers
ECMBR2

Neutral Lug Kit, ECLK1-2
wire range — #2-1 AWG
Cu or Al

Filler Plate, ECQF3

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

Riser Lug Kit
ECRLK250

Neutral Lug Kit, ECLK3
wire range — #1-300 MCM
Neutral Lug Kit, ECLK2
wire range — #4-#2/0 AWG
Cu or Al

For use on Ground Bar only
Collar Strap, Wire Range;
ECCS1; ECCS2

Add-A-Lock
(Flush Lock), ECQFL2
for Ultimate, ES & PL Load
Centers and 3-phase up to 225A

Add-A-Lock
(Flush Lock), ECQFL3
300-400A Load Centers

• Revised •
01/22/13

Load Centers
Manual Transfer Interlock Kits for Load Centers and Meter Combinations

n	 UL

listed for use in most
Siemens load centers and meter
combinations

Standby power
main breaker

Utility main breaker

MM0406L1*
MC1212L1200*

n	 Suitable

for use with optional
standby systems in accordance
with article 702 of the National
Electric Code

n	 Corrosion

resistant finish

n	 Easy

assembly requiring no
modifications to the load center
or meter combination

Wire forms
or bussing
To activate standby power the utility main
breaker must be in the “OFF” position to
prevent dangerous feedback between the
power sources.

n	 Remains

attached to the main
breakers when load center cover

Acceptable usage of Interlock Kits by load center/meter combination catalog numbers

ES Series Load Centers
can utilize interlock kits:
1, 2, 5, 6, 7. Kits 3 and 4
can also be used on main
breaker panels.

PL Series Load Centers
can utilize interlock kits:
1, 2, 3, 4, 5, 6, 7.

Numbers 1 through 9 in these tables represent
the last digit in each interlock kit catalog number.
Example: 1 = ECSBPK01

Siemens Meter Combinations
MC0816B1150RTH

5

7

MC2040S1200JLC

9

MC0816B1150T

5

7

MC2442B1225EFC

2

MC0816B1150TH

5

7

MC2442B1225ESC

2

MC0816B1200EFN

2

MC3040S1200SC

5

MC0816B1200RT

5

7

MC3042B1200FED

3

MC0816B1200RTB

5

7

MC3042B1200SED

3

MC0816B1200RTH

5

7

MC3042B1225FED

3

MC0816B1200ESN

2

MC3042B1225SED

3

MC0816B1200T

7

MC4040B1200SECW

5

7

MC0816B1200TH

5

7

MC4040S1200SC

5

7

MC0816B1350RLTM

5

7

MC0816B1200RJBT

8

MC0816B1400RLTM

5

7

MC0816B1150RJBT

8

MC1224B1100EFC

2

MC0816B1200RCT

8

MC1224B1100ESC

2

MC0816B1150RCT

8

MC1224B1125

1

MC0816B1200CT

8

2

MC1224B1125EFC

2

MC0816B1150CT

8

When used in horizontal positions as typical in
most load centers, ECSBPK07 is recommended for
use only with QNR type circuit breakers.

MC1224B1125ESC

2

MC2040B1150RCT

9

MC2040B1150

5

7

MC2040B1150CT

9

Standby power interlock kits are not intended for use
with AFCI, GFCI, 3-pole or 1/2” frame circuit breakers
and 4 space, 125 amp load centers.

MC2040B1200

5

7

MC2040B1200RCT

9

MC2040B1200R

5

7

MC2040B1200CT

9

Siemens type EQ load centers using a “4-pole” main
breaker do not have a kit available to interlock this
main to branch circuits. Branch circuit positions can be
interlocked.

7

	 No

interlock kit available for MC0816S1200SCT, MC2442S1200SC, MC2442S1200FC,
MC2040S1200SZ, MM02025S1200H, MM0202S1200RHJ, MM0202S1200RJB

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog

1-23

LOAD CENTERS &
CIRCUIT BREAKERS

Standard features

Panels in which the bussing or wire
forms from the meter socket land on
main lugs are not acceptable for use in
standby systems because turning the
main breaker to “OFF” does not prevent
feedback to the utility power lines.
Examples of such panels include catalog
numbers that start with the
following letters.
MC0606L1200*

1

Convert load centers or meter combinations into standby power panels

Load Centers
Prevents dangerous feedback between two sources of power

LOAD CENTERS &
CIRCUIT BREAKERS

1

Manual Transfer Interlock Kits for Load Centers and Meter Combinations
Catalog
number

Usage
Information

Utility main
breaker types

Standby main
breaker types

Interlock
number

ECSBPK01

For use on load centers or meter
combinations that will accept 2pole circuit breakers opposite
one another as shown.

QP, QPH, HQPH

QP, QPH, HQPH

1

ECSBPK02

For use on load centers or meter
combinations that will accept 2or 4-pole next to a 2-pole circuit
breaker side by side as shown.

QP, QPH, HQPH

QP, QPH, HQPH

2

ECSBPK03

For use on UltimateTM and Rock
Solid load centers, 150 amp and
higher, to connect the main breaker
to a 2-pole circuit breaker.

MBK150A,
MBK200A, OR
MBK225A

QP, QPH, HQPH

3

ECSBPK04

For use on Ultimate and Rock Solid
load centers, 125 amp and lower,
to connect the main breaker to a
2-pole circuit breaker.

MBK100A or
MBK125A

QP, QPH, HQPH

4

ECSBPK05

For use on load centers or meter meter
combinations that will accept a QNR
(MD-TR) frame circuit breaker next to
a 2-pole circuit breaker as shown.

QNR, QNRH, HQNR

QP, QPH, HQPH

5

ECSBPK06

For use on load centers or meter
combinations that will accept a QN
(MD-T) frame circuit breaker next
to a 2-pole circuit breaker as shown.

QN, QNH, HQN

QP, QPH, HQPH

6

ECSBPK07

For use on load centers or meter
combinations that will accept two QNR
(MD--TR) circuit breakers side by side as
shown OR will accept two QN (MD--T)
circuit breakers side by side as shown.

QNR, QNRH, HQNR,
QN, QNH, HQN

QNR, QNRH,
HQNR QN,
QNH, HQN

7

ECSBPK08

For use on 8 space, over/under,
OH/UG feed meter combinations
as shown. Limited application
to specific catalog numbers.

QPP, QPPH

QP, QPH, HQPH

8

ECSBPK09

For use on 20 space, over/under,
OH/UG feed meter combinations
as shown. Limited application to specific
catalog numbers.

QPP, QPPH

QP, QPH, HQPH

9

Manual breaker interlock kits are attached to the breakers not the trim of the load center.

1-24

These kits take up 2 spaces adjacent to the 2 pole
breaker being interlocked. Those spaces cannot
accommodate filler plates.

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog



Source Exif Data:
File Type                       : AI
File Type Extension             : ai
MIME Type                       : application/vnd.adobe.illustrator
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2014:03:30 19:05:05-04:00
Creator                         : Adobe InDesign CS4 (6.0.6)
Modify Date                     : 2014:03:30 19:12:07-04:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-21:37:19
Metadata Date                   : 2014:03:30 19:12:07-04:00
Creator Tool                    : Adobe InDesign CS4 (6.0.6)
Format                          : application/pdf
Document ID                     : uuid:5179926c-80f7-5643-88fe-90d7a5e6b7c9
Instance ID                     : uuid:07a640f7-9abd-b743-a5a2-df55a293d0e1
Producer                        : Adobe PDF Library 9.0
Page Count                      : 7
For                             : Susan Spencer,
Title                           : Untitled Extract Pages.pdf
Bounding Box                    : 0 0 603 783
Container Version               : 11
Creator Version                 : 14
Image Height                    : 783
Image Width                     : 603
Image Size                      : 603x783
Megapixels                      : 0.472
EXIF Metadata provided by EXIF.tools

Navigation menu