Cooper Crouse Hinds Condulet Conduit Outlet Boxes GUA Catalog Page
130656-Attachment 130656-Attachment 130656-Attachment Batch9 unilog cesco-content
2014-10-22
: Pdf 130980-Attachment 130980-Attachment Batch9 unilog
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRTEST06-3050-0 Name: 4F-50 4F 100: DATE: JAN 19 2006 Time: 6:16:10 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Condulet® Conduit Outlet Boxes Explosionproof Dust-Ignitionproof Raintight Wet Locations Cl. I, Div. 1 & 2, Groups C,D Cl. II, Div. 1, Groups E,F,G With Covers for Threaded Rigid and IMC Cl. II, Div. 2, Groups F,G Cl. III NEMA 3,4,7CD,9EFG Application: GUA series conduit outlet boxes are installed within hazardous area conduit systems to: ɀ protect conductors in threaded rigid conduit ɀ act as pull and splice boxes ɀ connect lengths of conduit ɀ change conduit direction ɀ provide access to conductors for maintenance and future system changes ɀ act as mounting outlets for fixtures (with appropriate covers) ɀ act as sealing fittings (with appropriate covers) Features: GUA conduit boxes have: ɀ Neoprene ‘‘O’’ ring standard to meet NEMA 4 requirements ɀ Cast ears on cover to permit easy removal and tightening ɀ Internal green ground screw ɀ Four standard mounting pads except for boxes with bottom hubs ɀ threaded cover openings ɀ ten different hub arrangements ɀ taper threaded hubs to provide grounding continuity ɀ smooth integral hub bushing protects conductor insulation when pulling ɀ surface covers furnished with boxes ɀ sealing covers, dome covers, and fixture hanger covers are available. ɀ cover threads are 12 pitch. Standard Materials: ɀ Bodies – Feraloy iron alloy ɀ Covers – Copper-free aluminum Standard Finishes: ɀ Feraloy iron alloy – electrogalvanized and aluminum acrylic paint ɀ Aluminum – natural Options: Suffix to be Added to Cat. # Description Bodies – copper-free aluminum . . . . . . . . . . . . . . . SA †* Covers – Feraloy iron alloy – electrogalvanized and aluminum acrylic paint . . . . . . . . . . . . . . . . . . . . WOD ɀ GUA Form 6 (with 3⍯ cover opening) are available with optional cover with viewing window. . . . . . . . . . . . . . . . . . . -VW Corro-free epoxy powder coat . . . . . . . . . . . . . S752 To order box less cover add ⍯0⍯ to end of catalog number ie.GUAT260. Certifications and Compliances: ɀ NEC/CEC: Class I, Division 1 & 2, Groups C,D Class II, Division 1, Groups E,F,G Class II, Division 2, Groups F,G Class III ɀ UL Standard: 886 ɀ ANSI Standard: C33.27 ɀ CSA Standard: C22.2 No. 30 ɀ NEMA/EEMAC 3,4 NOTE: When assembled with sealing type cover, GUA series outlet boxes provide adequate sealing for 40% fill in hazardous areas – Class I, Groups C,D; Class II, Groups E,F,G; and Class III. Seals can be made in either horizontal or vertical positions. Use Chico® ‘‘A’’ sealing compound or Chico® SpeedSeal only. Conductor splices or connections must not be made in enclosures where sealing compound is to be used per NEC. Dimensions GUAB Only GUA Hub Size 1⁄2 3⁄4 1⁄2 3⁄4 1 11⁄4 11⁄2 GUAC Cover Opening Dia. 2 2 3 3 3 35⁄8 5 Cat. # GUA14 GUA24 GUA16 GUA26* GUA36 GUA47 GUA59 Cover Opening Dia. 2 2 3 3 3 35⁄8 5 5 All others Size Ranges: ɀ Hub – 1⁄2⍯ to 2⍯ ɀ Cover opening – 2⍯ to 5⍯ dia. Hub Size 1⁄2 3⁄4 1⁄2 3⁄4 1 11⁄4 Cat. # GUAB14† GUAB24 GUAB16* GUAB26* GUAB36* GUAB47† GUAB59† GUAB69† Length of Hub Hub Size 1⁄2-3⁄4 1-11⁄4 11⁄2-2 Cat. # GUAC14† GUAC24† GUAC16* GUAC26* GUAC36* GUAC47† GUAC49 GUAC59† GUAC69† Cover Opening Dia. 2 2 3 3 3 5 Cat. # GUAD14† GUAD24 GUAD16 GUAD26† GUAD36† GUAD49 Dimension ‘‘e’’ Length 7⁄8 1 11⁄16 GUA, GUAD, GUAM, GUAW, GUAX Cat. # 14 24 16 26 36 37 47 49 59 69 † Available in copper-free aluminum, add suffix -SA. * Available in copper-free aluminum, add suffix -SA. GUA outlet boxes marked with * when ordered with suffix -SA are listed for Class I, Division 1 & 2, Groups B, C and D, Class II, Division 1, Groups E, F, G and Class III. Covers have 16 pitch threads. Replacement cover is a GUA06-GB. 50 Cover Opening Dia. 2 2 3 3 3 35⁄8 5 5 5 GUAD GUAB Hub Size 1⁄2 3⁄4 1⁄2 3⁄4 1 11⁄4 11⁄2 2 Hub Size 1⁄2 3⁄4 1⁄2 3⁄4 1 11⁄4 11⁄4 11⁄2 2 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds STIBOINFO((CRH:66008com:4F:50)) CH0 4 F - 0 3 S Crouse Hinds 1st Proof Authors Alterations A H M N a 21⁄2 21⁄2 31⁄2 31⁄2 31⁄2 41⁄4 41⁄4 53⁄4 53⁄4 53⁄4 b 113⁄16 2 2 2 25⁄16 25⁄16 211⁄16 313⁄16 313⁄16 41⁄16 c 13⁄4 2 17⁄8 17⁄8 23⁄16 23⁄8 23⁄4 33⁄4 33⁄4 4 d 5⁄8 3⁄4 5⁄8 3⁄4 7⁄8 7⁄8 13⁄32 13⁄32 19⁄32 19⁄16 Zoom: 100 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: 100: JOB: CRTEST06-3051-0 Name: 4F-51 DATE: JAN 19 2006 Time: 6:17:10 PM Operator: JB COLOR: CMYK TCP: 15001 Condulet® Conduit Outlet Boxes Hub Size 1⁄2 3⁄4 1⁄2 3⁄4 1 11⁄4 11⁄4 11⁄2 2 GUAN Cover Opening Dia. 2 2 3 3 3 35⁄8 5 5 5 Cat. # GUAL14† GUAL24† GUAL16* GUAL26* GUAL36* GUAL47† GUAL49† GUAL59† GUAL69† Hub Size 1⁄2 3⁄4 1⁄2 3⁄4 1 11⁄4 11⁄2 2 GUAT Cover Opening Dia. 2 2 3 3 3 35⁄8 5 5 Cat. # GUAN14 GUAN24 GUAN16 GUAN26 GUAN36† GUAN47 GUAN59† GUAN69 Cover Opening Dia. 2 2 3 3 Cat. # GUAW14† GUAW24† GUAW16 GUAL26† Hub Size 1⁄2 3⁄4 1⁄2 3⁄4 1 1 11⁄4 11⁄4 11⁄2 2 4F Exposionproof Dust-Ignitionproof Raintight Wet Locations Cl. I, Div. 1 & 2, Groups C,D Cl. II, Div. 1, Groups E,F,G With Covers for Threaded Rigid and IMC Cl. II, Div. 2, Groups F,G Cl. III NEMA 3,4,7CD,9EFG GUAL Typedriver Name: TS name csm no.: 100 GUAX Cover Opening Dia. 2 2 3 3 3 35⁄8 35⁄8 5 5 5 Cat. # GUAT14† GUAT24† GUAT16* GUAT26* GUAT36* GUAT37 GUAT47† GUAT49† GUAT59† GUAT69† Cover Opening Dia. 2 2 3 3 3 35⁄8 35⁄8 5 5 5 Hub Size 1⁄2 3⁄4 1⁄2 3⁄4 1 1 11⁄4 11⁄4 11⁄2 2 Cat. # GUAX14† GUAX24† GUAX16* GUAX26* GUAX36* GUAX37† GUAX47† GUAX49 GUAX59† GUAX69† GUAW GUAM Hub Size 1⁄2 3⁄4 1⁄2 3⁄4 1 11⁄4 2 Cover Opening Dia. 2 2 3 3 3 35⁄8 5 Cat. # GUAM14† GUAM24 GUAM16 GUAM26 GUAM36 GUAM47 GUAM69 Hub Size 1⁄2 3⁄4 1⁄2 3⁄4 Dimensions GUAC, GUAT Cat. # 14 24 16 26 36 37 47 49 59 69 a 21⁄2 21⁄2 31⁄2 31⁄2 31⁄2 41⁄4 41⁄4 53⁄4 53⁄4 53⁄4 b 21⁄4 2 2 2 25⁄16 25⁄16 211⁄16 313⁄16 313⁄16 41⁄16 c 23⁄16 2 17⁄8 17⁄8 23⁄16 23⁄8 23⁄4 33⁄4 33⁄4 4 d 5⁄8 3⁄4 5⁄8 3⁄4 7⁄8 7⁄8 13⁄32 15⁄32 19⁄32 19⁄16 GUAN Cat. # a b c d 14 24 16 26 36 47 59 69 21⁄2 21⁄2 31⁄2 31⁄2 31⁄2 41⁄4 53⁄4 53⁄4 21⁄8 25⁄16 2 2 25⁄16 211⁄16 41⁄16 41⁄16 21⁄16 21⁄4 17⁄8 17⁄8 23⁄8 23⁄4 4 4 5⁄8 3⁄4 3⁄4 3⁄4 7⁄8 13⁄32 19⁄32 19⁄16 GUAB, GUAL Cat. # a b 14 24 16 26 36 47 49 59 69 21⁄2 21⁄2 31⁄2 31⁄2 31⁄2 41⁄4 53⁄4 53⁄4 53⁄4 21⁄4 21⁄2 2 2 25⁄16 211⁄16 313⁄16 313⁄16 41⁄16 c d 23⁄16 27⁄16 17⁄8 17⁄8 23⁄16 23⁄4 33⁄4 33⁄4 4 5⁄8 3⁄4 5⁄8 3⁄4 7⁄8 13⁄32 15⁄32 19⁄32 19⁄16 * Available in copper-free aluminum, add suffix -SA. GUA outlet boxes marked with * when ordered with suffix-SA are listed for Class I, Division 1&2, Groups B, C and D, Class II, Division 1, Groups E, F, G and Class III. Covers have 16 pitch threads. Replacement cover is a GUA06-GB. † Available in copper-free aluminum, add suffix -SA. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds STIBOINFO((CRH:66008com:4F:51)) CH0 4 F - 0 4 S Crouse Hinds 1st Proof Authors Alterations A H M N 51 Zoom: 100
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:9f786a97-f9d3-49bd-837a-138ebb93e041 Producer : Acrobat Distiller 6.0.1 for Macintosh Modify Date : 2009:11:16 14:58:24-05:00 Create Date : 2006:01:19 18:16:21Z Metadata Date : 2009:11:16 14:58:24-05:00 Document ID : uuid:b2541980-8917-11da-aad0-000a95ec0d42 Instance ID : uuid:bacce4a9-b844-47ad-85f3-8bf85590499e Format : application/pdf Title : Cooper Crouse-Hinds - Condulet conduit outlet boxes - GUA catalog page Description : condbox_boxes_gua_cp.pdf Creator : Galco Industrial Electronics Author : Galco Industrial Electronics Subject : condbox_boxes_gua_cp.pdfEXIF Metadata provided by EXIF.tools