Brochure

2016-06-25

: Pdf 132519-Brochure 132519-Brochure B1 unilog

Open the PDF directly: View PDF PDF.
Page Count: 2

Product datasheet
Characteristics
CAD32FE7
TeSys D control relay -
3 NO + 2 NC
- <= 690 V -
115 V AC standard coil
Main
Range
TeSys
Product name
TeSys CAD
Product or component type
Control relay
Device short name
CAD
Contactor application
Control circuit
Utilisation category
AC
-14
AC
-15
DC-13
Pole contact composition
3 NO + 2 NC
[Ue] rated operational voltage
<= 690 V AC 25...400 Hz
Control circuit type
AC 50/60 Hz
Control circuit voltage
115 V AC 50/60 Hz
Complementary
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
[Ith] conventional free air thermal current
10 A at <= 60 °C
Irms rated making capacity
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
[Icw] rated short-time withstand current
100 A 1 s
120 A 500 ms
140 A 100 ms
Associated fuse rating
10 A gG conforming to IEC 60947-5-1
[Ui] rated insulation voltage
690 V conforming to IEC 60947-5-1
600 V certifications UL
600 V certifications CSA
Mounting support
Plate
Rail
Connections - terminals
Screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable
end
Screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable
end
Screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end
Screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable
end
Screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable
end
Screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable
end
Tightening torque
1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit voltage limits
0.3...0.6 Uc drop-out
0.8...1.1 Uc operational 50 Hz
0.85...1.1 Uc operational 60 Hz
Operating time
4...19 ms coil energisation and NC opening
12...22 ms coil energisation and NO closing
4...12 ms coil de-energisation and NO opening
6...17 ms coil de-energisation and NC closing
Mechanical durability
30 Mcycles
Operating rate
180 cyc/mn
Inrush power in VA
70 VA at 20 °C 50 Hz
Hold-in power consumption in VA
8 VA at 20 °C 50 Hz
Minimum switching voltage
17 V
Minimum switching current
5 mA
Theinformationprovidedinthisdocumentationcontainsgeneraldescriptionsand/ortechnicalcharacteristicsoftheperformanceoftheproductscontainedherein.
Thisdocumentationisnotintendedasasubstituteforandisnottobeusedfordeterminingsuitabilityorreliabilityoftheseproductsforspecificuserapplications.
Itisthedutyofanysuchuserorintegratortoperformtheappropriateandcompleteriskanalysis,evaluationandtestingoftheproductswithrespecttotherelevantspecificapplicationorusethereof.
NeitherSchneiderElectricIndustriesSASnoranyofitsaffiliatesorsubsidiariesshallberesponsibleorliableformisuseoftheinformationcontainedherein.
1 / 2
Non-overlap time
1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact)
Insulation resistance
> 10 MOhm
Height
77 mm
Width
45 mm
Depth
84 mm
Product weight
0.58 kg
Environment
Standards
BS 4794
EN 60947-5
IEC 60947-5-1
NF C 63-140
VDE 0660
Product certifications
CSA
UL
IP degree of protection
IP2x front face conforming to VDE 0106
Protective treatment
TH conforming to IEC 60068
Ambient air temperature for operation
-40...70 °C
Ambient air temperature for storage
-60...80 °C
Operating altitude
3000 m without derating in temperature
Mechanical robustness
Shocks control relay open 10 Gn for 11 ms IEC 60068-2-27
Shocks control relay closed 15 Gn for 11 ms IEC 60068-2-27
Vibrations control relay open 2 Gn, 5...300 Hz IEC 60068-2-6
Vibrations control relay closed 4 Gn, 5...300 Hz IEC 60068-2-6
Offer Sustainability
Sustainable offer status
Green Premium product
RoHS
Compliant - since 0627 - Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Available
Product end of life instructions
Need no specific recycling operations